Sample records for fluid samples collected

  1. Offline solid phase microextraction sampling system

    DOEpatents

    Harvey, Chris A.

    2008-12-16

    An offline solid phase microextraction (SPME) sampling apparatus for enabling SPME samples to be taken a number of times from a previously collected fluid sample (e.g. sample atmosphere) stored in a fused silica lined bottle which keeps volatile organics in the fluid sample stable for weeks at a time. The offline SPME sampling apparatus has a hollow body surrounding a sampling chamber, with multiple ports through which a portion of a previously collected fluid sample may be (a) released into the sampling chamber, (b) SPME sampled to collect analytes for subsequent GC analysis, and (c) flushed/purged using a fluidically connected vacuum source and purging fluid source to prepare the sampling chamber for additional SPME samplings of the same original fluid sample, such as may have been collected in situ from a headspace.

  2. Comparison of oral fluid collection methods for the molecular detection of hepatitis B virus.

    PubMed

    Portilho, M M; Mendonça, Acf; Marques, V A; Nabuco, L C; Villela-Nogueira, C A; Ivantes, Cap; Lewis-Ximenez, L L; Lampe, E; Villar, L M

    2017-11-01

    This study aims to compare the efficiency of four oral fluid collection methods (Salivette, FTA Card, spitting and DNA-Sal) to detect HBV DNA by qualitative PCR. Seventy-four individuals (32 HBV reactive and 42 with no HBV markers) donated serum and oral fluid. In-house qualitative PCR to detect HBV was used for both samples and commercial quantitative PCR for serum. HBV DNA was detected in all serum samples from HBV-infected individuals, and it was not detected in control group. HBV DNA from HBV group was detected in 17 samples collected with Salivette device, 16 samples collected by FTA Card device, 16 samples collected from spitting and 13 samples collected by DNA-Sal device. Samples that corresponded to a higher viral load in their paired serum sample could be detected using all oral fluid collection methods, but Salivette collection device yielded the largest numbers of positive samples and had a wide range of viral load that was detected. It was possible to detect HBV DNA using all devices tested, but higher number of positive samples was observed when samples were collected using Salivette device, which shows high concordance to viral load observed in the paired serum samples. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd. All rights reserved.

  3. Fluid sampling tool

    DOEpatents

    Garcia, Anthony R.; Johnston, Roger G.; Martinez, Ronald K.

    2000-01-01

    A fluid-sampling tool for obtaining a fluid sample from a container. When used in combination with a rotatable drill, the tool bores a hole into a container wall, withdraws a fluid sample from the container, and seals the borehole. The tool collects fluid sample without exposing the operator or the environment to the fluid or to wall shavings from the container.

  4. Detecting low levels of radionuclides in fluids

    DOEpatents

    Patch, Keith D.; Morgan, Dean T.

    2000-01-01

    An apparatus and method for detecting low levels of one or more radionuclides in a fluid sample uses a substrate that includes an ion exchange resin or other sorbent material to collect the radionuclides. A collecting apparatus includes a collecting chamber that exposes the substrate to a measured amount of the fluid sample such that radionuclides in the fluid sample are collected by the ion exchange resin. A drying apparatus, which can include a drying chamber, then dries the substrate. A measuring apparatus measures emissions from radionuclides collected on the substrate. The substrate is positioned in a measuring chamber proximate to a detector, which provides a signal in response to emissions from the radionuclides. Other analysis methods can be used to detect non-radioactive analytes, which can be collected with other types of sorbent materials.

  5. Technical note: A device for obtaining time-integrated samples of ruminal fluid

    USGS Publications Warehouse

    Corley, R. N.; Murphy, M.R.; Lucena, J.; Panno, S.V.

    1999-01-01

    A device was adapted to allow for time-integrated sampling of fluid from the rumen via a cannula. The sampler consisted of a cup-shaped ceramic filter positioned in the ventral rumen of a cannulated cow and attached to a tube through which fluid entering the filter was removed continuously using a peristaltic pump. Rate of ruminal fluid removal using the device was monitored over two 36-h periods (at 6-h intervals) and was not affected (P > .05) by time, indicating that the system was not susceptible to clogging during this period. Two cows having ad libitum access to a totally mixed ration were used in a split-block design to evaluate the utility of the system for obtaining time-integrated samples of ruminal fluid. Ruminal fluid VFA concentration and pattern in samples collected in two replicated 8-h periods by the time-integrated sampler (at 1-h intervals) were compared with composite samples collected using a conventional suction-strainer device (at 30-min intervals). Each 8-h collection period started 2 h before or 6 h after feeding. Results indicated that total VFA concentration was not affected (P > .05) by the sampling method. Volatile fatty acid patterns were likewise unaffected (P > .05) except that acetate was 2.5% higher (P < .05) in samples collected 2 h before feeding and valerate was 5% higher (P < .05) in samples collected 6 h after feeding by the suction-strainer device. Although significant, these differences were not considered physiologically important. We concluded that use of the ceramic filter improved the sampling of ruminal fluid by simplifying the technique and allowing time-integrated samples to be obtained.

  6. Analysis of cannabis in oral fluid specimens by GC-MS with automatic SPE.

    PubMed

    Choi, Hyeyoung; Baeck, Seungkyung; Kim, Eunmi; Lee, Sooyeun; Jang, Moonhee; Lee, Juseon; Choi, Hwakyung; Chung, Heesun

    2009-12-01

    Methamphetamine (MA) is the most commonly abused drug in Korea, followed by cannabis. Traditionally, MA analysis is carried out on both urine and hair samples and cannabis analysis in urine samples only. Despite the fact that oral fluid has become increasingly popular as an alternative specimen in the field of driving under the influence of drugs (DUID) and work place drug testing, its application has not been expanded to drug analysis in Korea. Oral fluid is easy to collect and handle and can provide an indication of recent drug abuse. In this study, we present an analytical method using GC-MS to determine tetrahydrocannabinol (THC) and its main metabolite 11-nor-delta9-tetrahydrocannabinol-9-carboxylic acid (THC-COOH) in oral fluid. The validated method was applied to oral fluid samples collected from drug abuse suspects and the results were compared with those in urine. The stability of THC and THC-COOH in oral fluid stored in different containers was also investigated. Oral fluid specimens from 12 drug abuse suspects, submitted by the police, were collected by direct expectoration. The samples were screened with microplate ELISA. For confirmation they were extracted using automated SPE with mixed-mode cation exchange cartridge, derivatized and analyzed by GC-MS using selective ion monitoring (SIM). The concentrations ofTHC and THC-COOH in oral fluid showed a large variation and the results from oral fluid and urine samples from cannabis abusers did not show any correlation. Thus, detailed information about time interval between drug use and sample collection is needed to interpret the oral fluid results properly. In addition, further investigation about the detection time window ofTHC and THC-COOH in oral fluid is required to substitute oral fluid for urine in drug testing.

  7. Measurement of Clozapine, Norclozapine, and Amisulpride in Plasma and in Oral Fluid Obtained Using 2 Different Sampling Systems.

    PubMed

    Fisher, Danielle S; Beyer, Chad; van Schalkwyk, Gerrit; Seedat, Soraya; Flanagan, Robert J

    2017-04-01

    There is a poor correlation between total concentrations of proton-accepting compounds (most basic drugs) in unstimulated oral fluid and in plasma. The aim of this study was to compare clozapine, norclozapine, and amisulpride concentrations in plasma and in oral fluid collected using commercially available collection devices [Thermo Fisher Scientific Oral-Eze and Greiner Bio-One (GBO)]. Oral-Eze and GBO samples and plasma were collected in that order from patients prescribed clozapine. Analyte concentrations were measured by liquid chromatography-tandem mass spectrometry. There were 112 participants [96 men, aged (median, range) 47 (21-65) years and 16 women, aged 44 (21-65) years]: 74 participants provided 2 sets of samples and 7 provided 3 sets (overall 2 GBO samples not collected). Twenty-three patients were co-prescribed amisulpride, of whom 17 provided 2 sets of samples and 1 provided 3 sets. The median (range) oral fluid within the GBO samples was 52 (13%-86%). Nonadherence to clozapine was identified in all 3 samples in one instance. After correction for oral fluid content, analyte concentrations in the GBO and Oral-Eze samples were poorly correlated with plasma clozapine and norclozapine (R = 0.57-0.63) and plasma amisulpride (R = 0.65-0.72). Analyte concentrations in the 2 sets of oral fluid samples were likewise poorly correlated (R = 0.68-0.84). Mean (SD) plasma clozapine and norclozapine were 0.60 (0.46) and 0.25 (0.21) mg/L, respectively. Mean clozapine and norclozapine concentrations in the 2 sets of oral fluid samples were similar to those in plasma (0.9-1.8 times higher), that is, approximately 2- to 3-fold higher than those in unstimulated oral fluid. The mean (±SD) amisulpride concentrations (microgram per liter) in plasma (446 ± 297) and in the Oral-Eze samples (501 ± 461) were comparable and much higher than those in the GBO samples (233 ± 318). Oral fluid collected using either the GBO system or the Oral-Eze system cannot be used for quantitative clozapine and/or amisulpride therapeutic drug monitoring.

  8. Magnetic particle translation as a surrogate measure for synovial fluid mechanics.

    PubMed

    Shah, Yash Y; Maldonado-Camargo, Lorena; Patel, Neal S; Biedrzycki, Adam H; Yarmola, Elena G; Dobson, Jon; Rinaldi, Carlos; Allen, Kyle D

    2017-07-26

    The mechanics of synovial fluid vary with disease progression, but are difficult to quantify quickly in a clinical setting due to small sample volumes. In this study, a novel technique to measure synovial fluid mechanics using magnetic nanoparticles is introduced. Briefly, microspheres embedded with superparamagnetic iron oxide nanoparticles, termed magnetic particles, are distributed through a 100μL synovial fluid sample. Then, a permanent magnet inside a protective sheath is inserted into the synovial fluid sample. Magnetic particles translate toward the permanent magnet and the percentage of magnetic particles collected by the magnet in a given time can be related to synovial fluid viscosity. To validate this relationship, magnetic particle translation was demonstrated in three phases. First, magnetic particle translation was assessed in glycerol solutions with known viscosities, demonstrating that as fluid viscosity increased, magnetic particle translation decreased. Next, the relationship between magnetic particle translation and synovial fluid viscosity was assessed using bovine synovial fluid that was progressively degenerated via ultrasonication. Here, particle collection in a given amount of time increased as fluid degenerated, demonstrating that the relationship between particle collection and fluid mechanics holds in non-Newtonian synovial fluid. Finally, magnetic particle translation was used to assess differences between healthy and OA affected joints in equine synovial fluid. Here, particle collection in a given time was higher in OA joints relative to healthy horses (p<0.001). Combined, these data demonstrate potential viability of magnetic particle translation in a clinical setting to evaluate synovial fluid mechanics in limited volumes of synovial fluid sample. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. THE EFFECT OF RATE OF GLAND FUNCTION ON PAROTID FLUID URIC ACID LEVELS.

    DTIC Science & Technology

    Paired parotid fluid samples were collected without exogenous stimulation and at 5 different gustation-induced rates of flow. Enzymatic uric acid...diminished as flow rate increased. It is suggested that parotid fluid samples for uric acid analysis should be collected at flow rates of 0.7 ml./min. or more. (Author)

  10. Fluid transport container

    DOEpatents

    DeRoos, Bradley G.; Downing, Jr., John P.; Neal, Michael P.

    1995-01-01

    An improved fluid container for the transport, collection, and dispensing of a sample fluid that maintains the fluid integrity relative to the conditions of the location at which it is taken. More specifically, the invention is a fluid sample transport container that utilizes a fitment for both penetrating and sealing a storage container under controlled conditions. Additionally, the invention allows for the periodic withdrawal of portions of the sample fluid without contamination or intermixing from the environment surrounding the sample container.

  11. Fluid sampling tool

    DOEpatents

    Johnston, Roger G.; Garcia, Anthony R. E.; Martinez, Ronald K.

    2001-09-25

    The invention includes a rotatable tool for collecting fluid through the wall of a container. The tool includes a fluid collection section with a cylindrical shank having an end portion for drilling a hole in the container wall when the tool is rotated, and a threaded portion for tapping the hole in the container wall. A passageway in the shank in communication with at least one radial inlet hole in the drilling end and an opening at the end of the shank is adapted to receive fluid from the container. The tool also includes a cylindrical chamber affixed to the end of the shank opposite to the drilling portion thereof for receiving and storing fluid passing through the passageway. The tool also includes a flexible, deformable gasket that provides a fluid-tight chamber to confine kerf generated during the drilling and tapping of the hole. The invention also includes a fluid extractor section for extracting fluid samples from the fluid collecting section.

  12. Metabolic profiling of body fluids and multivariate data analysis.

    PubMed

    Trezzi, Jean-Pierre; Jäger, Christian; Galozzi, Sara; Barkovits, Katalin; Marcus, Katrin; Mollenhauer, Brit; Hiller, Karsten

    2017-01-01

    Metabolome analyses of body fluids are challenging due pre-analytical variations, such as pre-processing delay and temperature, and constant dynamical changes of biochemical processes within the samples. Therefore, proper sample handling starting from the time of collection up to the analysis is crucial to obtain high quality samples and reproducible results. A metabolomics analysis is divided into 4 main steps: 1) Sample collection, 2) Metabolite extraction, 3) Data acquisition and 4) Data analysis. Here, we describe a protocol for gas chromatography coupled to mass spectrometry (GC-MS) based metabolic analysis for biological matrices, especially body fluids. This protocol can be applied on blood serum/plasma, saliva and cerebrospinal fluid (CSF) samples of humans and other vertebrates. It covers sample collection, sample pre-processing, metabolite extraction, GC-MS measurement and guidelines for the subsequent data analysis. Advantages of this protocol include: •Robust and reproducible metabolomics results, taking into account pre-analytical variations that may occur during the sampling process•Small sample volume required•Rapid and cost-effective processing of biological samples•Logistic regression based determination of biomarker signatures for in-depth data analysis.

  13. Fluid sampling tool

    DOEpatents

    Garcia, Anthony R.; Johnston, Roger G.; Martinez, Ronald K.

    1999-05-25

    A fluid sampling tool for sampling fluid from a container. The tool has a fluid collecting portion which is drilled into the container wall, thereby affixing it to the wall. The tool may have a fluid extracting section which withdraws fluid collected by the fluid collecting section. The fluid collecting section has a fluted shank with an end configured to drill a hole into a container wall. The shank has a threaded portion for tapping the borehole. The shank is threadably engaged to a cylindrical housing having an inner axial passageway sealed at one end by a septum. A flexible member having a cylindrical portion and a bulbous portion is provided. The housing can be slid into an inner axial passageway in the cylindrical portion and sealed to the flexible member. The bulbous portion has an outer lip defining an opening. The housing is clamped into the chuck of a drill, the lip of the bulbous section is pressed against a container wall until the shank touches the wall, and the user operates the drill. Wall shavings (kerf) are confined in a chamber formed in the bulbous section as it folds when the shank advances inside the container. After sufficient advancement of the shank, an o-ring makes a seal with the container wall.

  14. Fluid sampling tool

    DOEpatents

    Garcia, A.R.; Johnston, R.G.; Martinez, R.K.

    1999-05-25

    A fluid sampling tool is described for sampling fluid from a container. The tool has a fluid collecting portion which is drilled into the container wall, thereby affixing it to the wall. The tool may have a fluid extracting section which withdraws fluid collected by the fluid collecting section. The fluid collecting section has a fluted shank with an end configured to drill a hole into a container wall. The shank has a threaded portion for tapping the borehole. The shank is threadably engaged to a cylindrical housing having an inner axial passageway sealed at one end by a septum. A flexible member having a cylindrical portion and a bulbous portion is provided. The housing can be slid into an inner axial passageway in the cylindrical portion and sealed to the flexible member. The bulbous portion has an outer lip defining an opening. The housing is clamped into the chuck of a drill, the lip of the bulbous section is pressed against a container wall until the shank touches the wall, and the user operates the drill. Wall shavings (kerf) are confined in a chamber formed in the bulbous section as it folds when the shank advances inside the container. After sufficient advancement of the shank, an o-ring makes a seal with the container wall. 6 figs.

  15. Collection fluid helps preservation in voided urine cytology.

    PubMed

    Raistrick, J; Shambayati, B; Dunsmuir, W

    2008-04-01

    Degenerative change caused by delay in processing contributes to false-negative and false-positive diagnosis of urothelial carcinoma in cytology. The aim of the study was to see if the use of a collection fluid for urine samples made a significant difference to urine cytology diagnosis, and if one was better suited for routine use in the hospital laboratory. Three cell collection fluids were evaluated by analysing the preservation and degeneration of cells in urine samples, as was the routine preparation which did not use a collection fluid. In the design study 50 voided urine specimens were taken at random from the hospital haematuria clinic. Three commercially available collection fluids cytolyt, cytospin and cytoRich Blue and the hospital's routine conventional preparation of urine were compared. The degree of degeneration, and so preservation, was assessed by a table of chosen criteria; then ranked and analysed by Friedman's nonparametric test, at P = 0.05. A second table showing the cell content of each slide was also made. These showed no significant diagnostic difference between the collection fluids, but there was a significant difference between the collection fluids and the routine preparation. Minor differences that do not affect diagnosis, such as crystals and ghost red blood cells, were noted in cytospin and cytoRich Blue. It is recommended that a collection fluid is used. This choice should be made after health and safety issues and cost are considered.

  16. Detection of Nitrobenzodiazepines and Their 7-Amino Metabolites in Oral Fluid.

    PubMed

    Vindenes, Vigdis; Strand, Dag Helge; Koksæter, Paul; Gjerde, Hallvard

    2016-05-01

    Clonazepam, nitrazepam and flunitrazepam are frequently used benzodiazepines, both as prescribed medication and as drugs of abuse. Little is, however, known about how these drugs are excreted in oral fluid. It has been claimed that the parent drugs are more likely to be detected in oral fluid than the 7-amino metabolites. The aim of this study was to investigate whether the parent drugs or the 7-amino metabolites of the nitrobenzodiazepines were most frequently detected in authentic oral fluid samples. Oral fluid samples were collected from patients undergoing opioid maintenance treatment. Cases where clonazepam, nitrazepam, flunitrazepam and/or their metabolites were detected were included. The samples were collected using the Intercept Oral Specimen Collection Device. A cutoff concentration of 1 nM (∼0.3 ng/mL) in oral fluid-buffer mixture was applied for all the substances. A total of 1,001 oral fluid samples were positive for clonazepam and/or 7-aminoclonazepam; both substances were detected in 707 samples, only the parent drug in 64 cases and only the metabolite in 230 cases. For nitrazepam, both substances were detected in 139 samples; only the parent drug in 16 cases and only the metabolite in 56 cases. Flunitrazepam only was not detected in any sample; both substances were detected in one of these cases, and only the metabolite in three cases. This study revealed that 7-amino metabolites were more likely to be detected in oral fluid than the parent drugs. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  17. Optimising the collection of female genital tract fluid for cytokine analysis in pregnant women.

    PubMed

    Short, C S; Quinlan, R; Bennett, P; Shattock, R J; Taylor, G P

    2018-07-01

    To better understand the immunology of pregnancy, study of female genital tract fluid (FGF) is desirable. However the optimum method of collection of FGF in pregnant women for immunological methods, specifically cytokine measurement, is unknown. A prospective study of HIV-uninfected pregnant women comparing two methods of FGF collection: polyvinyl acetal sponge collection of cervical fluid (CF) and menstrual cup collection of cervicovaginal fluid (CVF). Samples were collected at 3 time points across the second and third trimesters: 14-21, 22-25 and 26-31 weeks. Multiplex chemi-luminescent assays were used to measure: IFN-γ, IL-1β, IL-2, IL-4, IL-6, IL-8, IL-10, IL-12, IL-13 and TNF-α. Optimal methodology for cytokine normalisation (sample weight, volume and total protein) was explored. All cytokines were measurable in both fluid types. IL-1β, IL-8 and IL-6 were detected at the highest concentrations (ranking order CF > CVF > plasma). CVF collection was simpler, provided the largest volume of sample (median 0.5 g) with the potential for undiluted usage, and allowed for self-insertion. CF cytokine concentrations were intrinsically associated with sample weight and protein concentration however CVF cytokines were independent of these. Both methods of collection are robust for measurement of FGF cytokines during pregnancy. We recommend CVF collection using a menstrual cup as a viable option in pregnant women for high dimensional biological techniques. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.

  18. Driving under the influence of cannabis: pitfalls, validation, and quality control of a UPLC-MS/MS method for the quantification of tetrahydrocannabinol in oral fluid collected with StatSure, Quantisal, or Certus collector.

    PubMed

    Wille, Sarah M R; Di Fazio, Vincent; Ramírez-Fernandez, Maria del Mar; Kummer, Natalie; Samyn, Nele

    2013-02-01

    "Driving under the influence of drugs" (DUID) has a large impact on the worldwide mortality risk. Therefore, DUID legislations based on impairment or analytical limits are adopted. Drug detection in oral fluid is of interest due to the ease of sampling during roadside controls. The prevalence of Δ9-tetrahydrocannabinol (THC) in seriously injured drivers ranges from 0.5% to 7.6% in Europe. For these reasons, the quantification of THC in oral fluid collected with 3 alternative on-site collectors is presented and discussed in this publication. An ultra-performance liquid chromatography-mass spectrometric quantification method for THC in oral fluid samples collected with the StatSure (Diagnostic Systems), Quantisal (Immunalysis), and Certus (Concateno) devices was validated according to the international guidelines. Small sample volumes of 100-200 μL were extracted using hexane. Special attention was paid to factors such as matrix effects, THC adsorption onto the collector, and stability in the collection fluid. A relatively high-throughput analysis was developed and validated according to ISO 17025 requirements. Although the effects of the matrix on the quantification could be minimized using a deuterated internal standard, and stability was acceptable according the validation data, adsorption of THC onto the collectors was a problem. For the StatSure device, THC was totally recovered from the collector pad after storage for 24 hours at room temperature or 7 days at 4°C. A loss of 15%-25% was observed for the Quantisal collector, whereas the recovery from the Certus device was irreproducible (relative standard deviation, 44%-85%) and low (29%-80%). During the roadside setting, a practical problem arose: small volumes of oral fluid (eg, 300 μL) were collected. However, THC was easily detected and concentrations ranged from 8 to 922 ng/mL in neat oral fluid. A relatively high-throughput analysis (40 samples in 4 hours) adapted for routine DUID analysis was developed and validated for THC quantification in oral fluid samples collected from drivers under the influence of cannabis.

  19. Endoscopic Management of Pancreatic Fluid Collections in Children.

    PubMed

    Nabi, Zaheer; Talukdar, Rupjyoti; Reddy, D Nageshwar

    2017-07-15

    The incidence of acute pancreatitis in children has increased over the last few decades. The development of pancreatic fluid collection is not uncommon after severe acute pancreatitis, although its natural course in children and adolescents is poorly understood. Asymptomatic fluid collections can be safely observed without any intervention. However, the presence of clinically significant symptoms warrants the drainage of these fluid collections. Endoscopic management of pancreatic fluid collection is safe and effective in adults. The use of endoscopic ultrasound (EUS)-guided procedure has improved the efficacy and safety of drainage of pancreatic fluid collections, which have not been well studied in pediatric populations, barring a scant volume of small case series. Excellent results of EUS-guided drainage in adult patients also need to be verified in children and adolescents. Endoprostheses used to drain pancreatic fluid collections include plastic and metal stents. Metal stents have wider lumens and become clogged less often than plastic stents. Fully covered metal stents specifically designed for pancreatic fluid collection are available, and initial studies have shown encouraging results in adult patients. The future of endoscopic management of pancreatic fluid collection in children appears promising. Prospective studies with larger sample sizes are required to establish their definitive role in the pediatric age group.

  20. Probability of detecting Porcine reproductive and respiratory syndrome virus infection using pen-based swine oral fluid specimens as a function of within-pen prevalence.

    PubMed

    Olsen, Chris; Wang, Chong; Christopher-Hennings, Jane; Doolittle, Kent; Harmon, Karen M; Abate, Sarah; Kittawornrat, Apisit; Lizano, Sergio; Main, Rodger; Nelson, Eric A; Otterson, Tracy; Panyasing, Yaowalak; Rademacher, Chris; Rauh, Rolf; Shah, Rohan; Zimmerman, Jeffrey

    2013-05-01

    Pen-based oral fluid sampling has proven to be an efficient method for surveillance of infectious diseases in swine populations. To better interpret diagnostic results, the performance of oral fluid assays (antibody- and nucleic acid-based) must be established for pen-based oral fluid samples. Therefore, the objective of the current study was to determine the probability of detecting Porcine reproductive and respiratory syndrome virus (PRRSV) infection in pen-based oral fluid samples from pens of known PRRSV prevalence. In 1 commercial swine barn, 25 pens were assigned to 1 of 5 levels of PRRSV prevalence (0%, 4%, 12%, 20%, or 36%) by placing a fixed number (0, 1, 3, 5, or 9) of PRRSV-positive pigs (14 days post PRRSV modified live virus vaccination) in each pen. Prior to placement of the vaccinated pigs, 1 oral fluid sample was collected from each pen. Thereafter, 5 oral fluid samples were collected from each pen, for a total of 150 samples. To confirm individual pig PRRSV status, serum samples from the PRRSV-negative pigs (n = 535) and the PRRSV vaccinated pigs (n = 90) were tested for PRRSV antibodies and PRRSV RNA. The 150 pen-based oral fluid samples were assayed for PRRSV antibody and PRRSV RNA at 6 laboratories. Among the 100 samples from pens containing ≥1 positive pig (≥4% prevalence) and tested at the 6 laboratories, the mean positivity was 62% for PRRSV RNA and 61% for PRRSV antibody. These results support the use of pen-based oral fluid sampling for PRRSV surveillance in commercial pig populations.

  1. Clinical and technical considerations in the analysis of gingival crevicular fluid.

    PubMed

    Wassall, Rebecca R; Preshaw, Philip M

    2016-02-01

    Despite the technical challenges involved when collecting, processing and analyzing gingival crevicular fluid samples, research using gingival crevicular fluid has, and will continue to play, a fundamental role in expanding our understanding of periodontal pathogenesis and healing outcomes following treatment. A review of the literature, however, clearly demonstrates that there is considerable variation in the methods used for collection, processing and analysis of gingival crevicular fluid samples by different research groups around the world. Inconsistent or inadequate reporting impairs interpretation of results, prevents accurate comparison of data between studies and potentially limits the conclusions that can be made from a larger body of evidence. The precise methods used for collection and analysis of gingival crevicular fluid (including calibration studies required before definitive clinical studies) should be reported in detail, either in the methods section of published papers or as an online supplementary file, so that other researchers may reproduce the methodology. Only with clear and transparent reporting will the full impact of future gingival crevicular fluid research be realized. This paper discusses the complexities of gingival crevicular fluid collection and analysis and provides guidance to researchers working in this field. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  2. Development and field application of a 6-bottle serial gas-tight fluid sampler for collecting seafloor cold seep and hydrothermal vent fluids with autonomous operation capability

    NASA Astrophysics Data System (ADS)

    Wu, S.; Ding, K.; Yang, C.; Seyfried, W. E., Jr.; Tan, C.; Schaen, A. T.; Luhmann, A. J.

    2014-12-01

    A 6-bottle serial gas-tight sampler (so-called "six-shooter") was developed for application with deep-sea vent fluids. The new device is composed of a custom-made 6-channel valve manifold and six sampling bottles which are circularly distributed around the valve manifold. Each valve channel consists of a high-pressure titanium cartridge valve and a motor-driven actuator. A sampling snorkel is connected to the inlet of the manifold that delivers the incoming fluid to different bottles. Each sampling bottle has a 160 ml-volume chamber and an accumulator chamber inside where compressed nitrogen is used to maintain the sample at near in-situ pressure. An electronics chamber that is located at the center of the sampler is used to carry out all sampling operations, autonomously, if desired. The sampler is of a compact circular configuration with a diameter of 26 cm and a length of 54 cm. During the SVC cruise AT 26-12, the sampler was deployed by DSV2 Alvin at a cold seep site MC036 with a depth of 1090 m in the Gulf of Mexico. The sampler collected fluid samples automatically following the tidal cycle to monitor the potential impact of the tide cycle on the fluid chemistry of cold seep in a period of two day. During the cruise AT 26-17, the sampler was used with newly upgraded DSV2 Alvin three times at the hydrothermal vent sites along Axial Seamount and Main Endeavor Field on Juan de Fuca Ridge. During a 4-day deployment at Anemone diffuse site (Axial Caldera), the sampler was set to work in an autonomous mode to collect fluid samples according to the preset interval. During other dives, the sampler was manually controlled via ICL (Inductively Coupled Link) communication through the hull. Gas-tight fluid samples were collected from different hydrothermal vents with temperatures between 267 ℃ and 335 ℃ at the depth up to 2200 m. The field results indicate unique advantages of the design. It can be deployed in extended time period with remote operation or working autonomously taking gas-tight fluid samples. If used with HOV or ROV, it will reduce basket space occupation and ICL communication cables compared to traditional single-bottle gas-tight samplers. This time serial gas-tight fluid sampler will be further developed into a 36 bottle system for remote operation with seafloor cabled observatory.

  3. Nanopipettes: probes for local sample analysis.

    PubMed

    Saha-Shah, Anumita; Weber, Anna E; Karty, Jonathan A; Ray, Steven J; Hieftje, Gary M; Baker, Lane A

    2015-06-01

    Nanopipettes (pipettes with diameters <1 μm) were explored as pressure-driven fluid manipulation tools for sampling nanoliter volumes of fluids. The fundamental behavior of fluids confined in the narrow channels of the nanopipette shank was studied to optimize sampling volume and probe geometry. This method was utilized to collect nanoliter volumes (<10 nL) of sample from single Allium cepa cells and live Drosophila melanogaster first instar larvae. Matrix assisted laser desorption/ionization-mass spectrometry (MALDI-MS) was utilized to characterize the collected sample. The use of nanopipettes for surface sampling of mouse brain tissue sections was also explored. Lipid analyses were performed on mouse brain tissues with spatial resolution of sampling as small as 50 μm. Nanopipettes were shown to be a versatile tool that will find further application in studies of sample heterogeneity and population analysis for a wide range of samples.

  4. Hydraulic Fracturing Fluid Analysis for Regulatory Parameters - A Progress Report

    EPA Pesticide Factsheets

    This presentation is a progress report on the analysis of Hydraulic Fracturing Fluids for regulatory compounds outlined in the various US EPA methodologies. Fracturing fluids vary significantly in consistency and viscosity prior to fracturing. Due to the nature of the fluids the analytical challenges will have to be addressed. This presentation also outlines the sampling issues associated with the collection of dissolved gas samples.

  5. Oral vs. salivary diagnostics

    NASA Astrophysics Data System (ADS)

    Marques, Joana; Corby, Patricia M.; Barber, Cheryl A.; Abrams, William R.; Malamud, Daniel

    2015-05-01

    The field of "salivary diagnostics" includes studies utilizing samples obtained from a variety of sources within the oral cavity. These samples include; whole unstimulated saliva, stimulated whole saliva, duct saliva collected directly from the parotid, submandibular/sublingual glands or minor salivary glands, swabs of the buccal mucosa, tongue or tonsils, and gingival crevicular fluid. Many publications state "we collected saliva from subjects" without fully describing the process or source of the oral fluid. Factors that need to be documented in any study include the time of day of the collection, the method used to stimulate and collect the fluid, and how much fluid is being collected and for how long. The handling of the oral fluid during and post-collection is also critical and may include addition of protease or nuclease inhibitors, centrifugation, and cold or frozen storage prior to assay. In an effort to create a standard protocol for determining a biomarker's origin we carried out a pilot study collecting oral fluid from 5 different sites in the mouth and monitoring the concentrations of pro- and anti-inflammatory cytokines detected using MesoScaleDiscovery (MSD) electrochemiluminesence assays. Our data suggested that 3 of the cytokines are primarily derived from the submandibular gland, while 7 of the cytokines come from a source other than the major salivary glands such as the minor salivary glands or cells in the oral mucosae. Here we review the literature on monitoring biomarkers in oral samples and stress the need for determining the blood/saliva ratio when a quantitative determination is needed and suggest that the term oral diagnostic be used if the source of an analyte in the oral cavity is unknown.

  6. Microfluidic device and method for focusing, segmenting, and dispensing of a fluid stream

    DOEpatents

    Jacobson, Stephen C [Knoxville, TN; Ramsey, J Michael [Knoxville, TN

    2008-09-09

    A microfluidic device and method for forming and dispensing minute volume segments of a material are described. In accordance with the present invention, a microfluidic device and method are provided for spatially confining the material in a focusing element. The device is also adapted for segmenting the confined material into minute volume segments, and dispensing a volume segment to a waste or collection channel. The device further includes means for driving the respective streams of sample and focusing fluids through respective channels into a chamber, such that the focusing fluid streams spatially confine the sample material. The device may also include additional means for driving a minute volume segment of the spatially confined sample material into a collection channel in fluid communication with the waste reservoir.

  7. Microfluidic device and method for focusing, segmenting, and dispensing of a fluid stream

    DOEpatents

    Jacobson, Stephen C.; Ramsey, J. Michael

    2004-09-14

    A microfluidic device for forming and/or dispensing minute volume segments of a material is described. In accordance with one aspect of the present invention, a microfluidic device and method is provided for spatially confining the material in a focusing element. The device is also capable of segmenting the confined material into minute volume segments, and dispensing a volume segment to a waste or collection channel. The device further includes means for driving the respective streams of sample and focusing fluids through respective channels into a chamber, such that the focusing fluid streams spatially confine the sample material. The device may also include additional means for driving a minute volume segment of the spatially confined sample material into a collection channel in fluid communication with the waste reservoir.

  8. Comparison of microdialysis sampling perfusion fluid components on the foreign body reaction in rat subcutaneous tissue.

    PubMed

    Keeler, Geoffrey D; Durdik, Jeannine M; Stenken, Julie A

    2014-06-16

    Microdialysis sampling is a commonly used technique for collecting solutes from the extracellular space of tissues in laboratory animals and humans. Large molecular weight solutes can be collected using high molecular weight cutoff (MWCO) membranes (100kDa or greater). High MWCO membranes require addition of high molecular weight dextrans or albumin to the perfusion fluid to prevent fluid loss via ultrafiltration. While these perfusion fluid additives are commonly used during microdialysis sampling, the tissue response to the loss of these compounds across the membrane is poorly understood. Tissue reactions to implanted microdialysis sampling probes containing different microdialysis perfusion fluids were compared over a 7-day time period in rats. The base perfusion fluid was Ringer's solution supplemented with either bovine serum albumin (BSA), rat serum albumin (RSA), Dextran-70, or Dextran-500. A significant inflammatory response to Dextran-70 was observed. No differences in the tissue response between BSA and RSA were observed. Among these agents, the BSA, RSA, and Dextran-500 produced a significantly reduced inflammatory response compared to the Dextran-70. This work demonstrates that use of Dextran-70 in microdialysis sampling perfusion fluids should be eliminated and replaced with Dextran-500 or other alternatives. Copyright © 2013 Elsevier B.V. All rights reserved.

  9. Evaluation of a commercial rubella IgM assay for use on oral fluid samples for diagnosis and surveillance of congenital rubella syndrome and postnatal rubella.

    PubMed

    Vijaylakshmi, P; Muthukkaruppan, V R; Rajasundari, A; Korukluoglu, G; Nigatu, W; L A Warrener; Samuel, D; Brown, D W G

    2006-12-01

    Clinical diagnosis (surveillance) of rubella is unreliable and laboratory confirmation is essential. Detection of virus specific IgM in serum is the most commonly used method. However, the use of serum necessitates the drawing of blood, either through venipuncture or finger/heel prick, which can be difficult in young babies. Oral fluid samples have proved useful as an alternative, less invasive sample for virus specific IgM detection however until recently no commercial rubella IgM tests were available, restricting the usefulness of this approach. To evaluate the performance of the Microimmune Rubella IgM capture EIA using oral fluid samples from outbreaks as well as in cases of suspected congenital rubella syndrome (CRS). Paired serum and oral fluids were collected from cases during a rubella outbreak in three provinces in Turkey. Matched serum and oral fluid samples were collected from children with suspected CRS in an active surveillance programme at the Aravind Eye Hospital in South India. Serum samples were collected as part of the measles surveillance programme in Ethiopia. On serum samples the sensitivity and specificity of the Microimmune Rubella IgM capture EIA compared to Behring Enzygnost rubella IgM test was 96.9% (62/64; 95% CI 94.2-100%) and 100% (53/53; 95% CI 93.2-100%). On oral fluids compared to matched Behring results on serum the sensitivity was 95.5% (42/44; 95% CI 84.5-99.4%). The sensitivity and specificity of Microimmune Rubella IgM capture EIA on oral fluids from suspected CRS cases compared to serum results using Behring Enzygnost IgM assay was 100% (95% CI 84.5-100%) and 100% (95% CI 95.8-100.0%) respectively. Microimmune Rubella IgM capture EIA has adequate performance for diagnosis and surveillance of rubella in outbreak using either serum or oral fluid specimens.

  10. Photonic-crystal fiber as a multifunctional optical sensor and sample collector.

    PubMed

    Konorov, Stanislav; Zheltikov, Aleksei; Scalora, Michael

    2005-05-02

    Two protocols of optical sensing realized with the same photonic-crystal fiber are compared. In the first protocol, diode-laser radiation is delivered to a sample through the central core of a dual-cladding photonic-crystal fiber with a diameter of a few micrometers, while the large-diameter fiber cladding serves to collect the fluorescent response from the sample and to guide it to a detector in the backward direction. In the second scheme, liquid sample is collected by a microcapillary array in the fiber cladding and is interrogated by laser radiation guided in the fiber modes. For sample fluids with refractive indices exceeding the refractive index of the fiber material, fluid channels in photonic-crystal fibers can guide laser light by total internal reflection, providing an 80% overlap of interrogating radiation with sample fluid.

  11. Extended Detection of Amphetamine and Methamphetamine in Oral Fluid.

    PubMed

    Andås, Hilde T; Enger, Asle; Øiestad, Åse Marit L; Vindenes, Vigdis; Christophersen, Asbjørg S; Huestis, Marilyn A; Øiestad, Elisabeth L

    2016-02-01

    Amphetamine and methamphetamine are popular drugs of abuse worldwide and are important components of drug monitoring programs. Windows of detection for amphetamine and methamphetamine in oral fluid after high doses have not been investigated. Repeated high-dose ingestions are likely to cause positive samples for extended periods. Common routes of administration of amphetamine/methamphetamine in Norway are oral intake or injection. The aim of this study was to investigate windows of detection for amphetamine and methamphetamine in oral fluid from drug addicts under sustained abstinence during detoxification. Twenty-five patients admitted to a closed detoxification unit were included in this study. Oral fluid samples were collected daily in the morning and evening, and urine every morning for 10 days. A blood sample was drawn during the first 5 days after admission if the patient consented. Oral fluid results were compared with urine results to determine whether a new ingestion occurred. Oral fluid was collected with the Intercept oral fluid collection device. In-house cutoff concentrations for amphetamine and methamphetamine were 6.8 and 7.5 mcg/L, respectively, in oral fluid, and 135 and 149 mcg/L, respectively, in urine. Amphetamines were detected in 11 oral fluid, 5 urine, and 2 blood specimens from 25 patients. Patients self-reported amphetamines intake of up to 0.5-2 g daily. Windows of detection for amphetamine and methamphetamine in oral fluid were up to 8 days, longer than in urine at the applied cutoff values. These data confirm that oral fluid is a viable alternative to urine for monitoring amphetamine abuse, and that these substances might be detected in oral fluid for at least 1 week after ingestion of high doses. Such long detection times were, as far as we are aware, never reported previously for oral fluid amphetamines.

  12. Process and apparatus for obtaining samples of liquid and gas from soil

    DOEpatents

    Rossabi, J.; May, C.P.; Pemberton, B.E.; Shinn, J.; Sprague, K.

    1999-03-30

    An apparatus and process for obtaining samples of liquid and gas from subsurface soil is provided having filter zone adjacent an external expander ring. The expander ring creates a void within the soil substrate which encourages the accumulation of soil-borne fluids. The fluids migrate along a pressure gradient through a plurality of filters before entering a first chamber. A one-way valve regulates the flow of fluid into a second chamber in further communication with a collection tube through which samples are collected at the surface. A second one-way valve having a reverse flow provides additional communication between the chambers for the pressurized cleaning and back-flushing of the apparatus. 8 figs.

  13. Process and apparatus for obtaining samples of liquid and gas from soil

    DOEpatents

    Rossabi, Joseph; May, Christopher P.; Pemberton, Bradley E.; Shinn, Jim; Sprague, Keith

    1999-01-01

    An apparatus and process for obtaining samples of liquid and gas from subsurface soil is provided having filter zone adjacent an external expander ring. The expander ring creates a void within the soil substrate which encourages the accumulation of soil-borne fluids. The fluids migrate along a pressure gradient through a plurality of filters before entering a first chamber. A one-way valve regulates the flow of fluid into a second chamber in further communication with a collection tube through which samples are collected at the surface. A second one-way valve having a reverse flow provides additional communication between the chambers for the pressurized cleaning and back-flushing of the apparatus.

  14. Comparative Proteomic Analysis of Whole-Gut Lavage Fluid and Pancreatic Juice Reveals a Less Invasive Method of Sampling Pancreatic Secretions

    PubMed Central

    Rocker, Jana M; Tan, Marcus C; Thompson, Lee W; Contreras, Carlo M; DiPalma, Jack A; Pannell, Lewis K

    2016-01-01

    OBJECTIVES: There are currently no reliable, non-invasive screening tests for pancreatic ductal adenocarcinoma. The fluid secreted from the pancreatic ductal system (“pancreatic juice”) has been well-studied as a potential source of cancer biomarkers. However, it is invasive to collect. We recently observed that the proteomic profile of intestinal effluent from the bowel in response to administration of an oral bowel preparation solution (also known as whole-gut lavage fluid, WGLF) contains large amounts of pancreas-derived proteins. We therefore hypothesized that the proteomic profile is similar to that of pancreatic juice. In this study, we compared the proteomic profiles of 77 patients undergoing routine colonoscopy with the profiles of 19 samples of pure pancreatic juice collected during surgery. METHODS: WGLF was collected from patients undergoing routine colonoscopy, and pancreatic juice was collected from patients undergoing pancreatic surgery. Protein was isolated from both samples using an optimized method and analyzed by LC-MS/MS. Identified proteins were compared between samples and groups to determine similarity of the two fluids. We then compared our results with literature reports of pancreatic juice-based studies to determine similarity. RESULTS: We found 104 proteins in our pancreatic juice samples, of which 90% were also found in our WGLF samples. The majority (67%) of the total proteins found in the WGLF were common to pancreatic juice, with intestine-specific proteins making up a smaller proportion. CONCLUSIONS: WGLF and pancreatic juice appear to have similar proteomic profiles. This supports the notion that WGLF is a non-invasive, surrogate bio-fluid for pancreatic juice. Further studies are required to further elucidate its role in the diagnosis of pancreatic cancer. PMID:27228405

  15. Comparison of direct sampling and brochoalveolar lavage for determining active drug concentrations in the pulmonary epithelial lining fluid of calves injected with enrofloxacin or tilmicosin.

    PubMed

    Foster, D M; Sylvester, H J; Papich, M G

    2017-12-01

    Antibiotic distribution to interstitial fluid (ISF) and pulmonary epithelial fluid (PELF) was measured and compared to plasma drug concentrations in eight healthy calves. Enrofloxacin (Baytril ® 100) was administered at a dose of 12.5 mg/kg subcutaneously (SC), and tilmicosin (Micotil ® 300) was administered at a dose of 20 mg/kg SC. PELF, sampled by two different methods-bronchoalveolar lavage (BAL) and direct sampling (DS)-plasma, and ISF were collected from each calf and measured for tilmicosin, enrofloxacin and its metabolite ciprofloxacin by HPLC. Pharmacokinetic analysis was performed on the concentrations in each fluid, for each drug. The enrofloxacin/ciprofloxacin concentration as measured by AUC in DS samples was 137 ± 72% higher than in plasma, but in BAL samples, this value was 535 ± 403% (p < .05). The concentrations of tilmicosin in DS and BAL samples exceeded plasma drug concentrations by 567 ± 189% and 776 ± 1138%, respectively. The enrofloxacin/ciprofloxacin concentrations collected by DS were significantly different than those collected by BAL, but the tilmicosin concentrations were not significantly different between the two methods. Concentrations of enrofloxacin/ciprofloxacin exceeded the MIC values for bovine respiratory disease pathogens but tilmicosin did not reach MIC levels for these pathogens in any fluids. © 2017 John Wiley & Sons Ltd.

  16. Recovery of a fish pathogenic bacterium, Aeromonas salmonicida, from ebonyshell mussels Fusconaia ebena using nondestructive sample collection procedures

    USGS Publications Warehouse

    Starliper, C.E.

    2008-01-01

    Refugia are increasingly being used to maintain and propagate imperiled freshwater mussels for future population augmentations. Success for this endeavor is dependent on good husbandry, including a holistic program of resource health management. A significant aspect to optimal health is the prevention or control of infectious diseases. Describing and monitoring pathogens and diseases in mussels involves examination of tissues or samples collected from an appropriate number of individuals that satisfies a certain confidence level for expected prevalences of infections. In the present study, ebonyshell mussels Fusconaia ebena were infected with a fish pathogenic bacterium, Aeromonas salmonicida, through their cohabitation with diseased brook trout Salvelinus fontinalis. At a 100% prevalence of infection, the F. ebena were removed from the cohabitation tank to clean tanks that were supplied with pathogen-free water, which initiated their depuration of A. salmonicida. Three samples (nondestructive fluid, mantle, hemolymph) collected using nondestructive procedures were compared with fluids and soft tissue homogenates collected after sacrificing the mussels for recovery of the bacterium during this period of depuration. Nondestructive sample collections, especially ND fluid, provide a comparable alternative to sacrificing mussels to determine pathogen status.

  17. Nanopipettes: probes for local sample analysis† †Electronic supplementary information (ESI) available. See DOI: 10.1039/c5sc00668f Click here for additional data file.

    PubMed Central

    Saha-Shah, Anumita; Weber, Anna E.; Karty, Jonathan A.; Ray, Steven J.; Hieftje, Gary M.

    2015-01-01

    Nanopipettes (pipettes with diameters <1 μm) were explored as pressure-driven fluid manipulation tools for sampling nanoliter volumes of fluids. The fundamental behavior of fluids confined in the narrow channels of the nanopipette shank was studied to optimize sampling volume and probe geometry. This method was utilized to collect nanoliter volumes (<10 nL) of sample from single Allium cepa cells and live Drosophila melanogaster first instar larvae. Matrix assisted laser desorption/ionization-mass spectrometry (MALDI-MS) was utilized to characterize the collected sample. The use of nanopipettes for surface sampling of mouse brain tissue sections was also explored. Lipid analyses were performed on mouse brain tissues with spatial resolution of sampling as small as 50 μm. Nanopipettes were shown to be a versatile tool that will find further application in studies of sample heterogeneity and population analysis for a wide range of samples. PMID:28706697

  18. Detection of Classical swine fever virus infection by individual oral fluid of pigs following experimental inoculation.

    PubMed

    Petrini, Stefano; Pierini, Ilaria; Giammarioli, Monica; Feliziani, Francesco; De Mia, Gian Mario

    2017-03-01

    We evaluated the use of oral fluid as an alternative to serum samples for Classical swine fever virus (CSFV) detection. Individual oral fluid and serum samples were collected at different times post-infection from pigs that were experimentally inoculated with CSFV Alfort 187 strain. We found no evidence of CSFV neutralizing antibodies in swine oral fluid samples under our experimental conditions. In contrast, real-time reverse transcription-polymerase chain reaction could detect CSFV nucleic acid from the oral fluid as early as 8 d postinfection, which also coincided with the time of initial detection in blood samples. The probability of CSFV detection in oral fluid was identical or even higher than in the corresponding blood sample. Our results support the feasibility of using this sampling method for CSFV genome detection, which may represent an additional cost-effective tool for CSF control.

  19. Fluid sample collection and distribution system. [qualitative analysis of aqueous samples from several points

    NASA Technical Reports Server (NTRS)

    Brooks, R. L. (Inventor)

    1979-01-01

    A multipoint fluid sample collection and distribution system is provided wherein the sample inputs are made through one or more of a number of sampling valves to a progressive cavity pump which is not susceptible to damage by large unfiltered particles. The pump output is through a filter unit that can provide a filtered multipoint sample. An unfiltered multipoint sample is also provided. An effluent sample can be taken and applied to a second progressive cavity pump for pumping to a filter unit that can provide one or more filtered effluent samples. The second pump can also provide an unfiltered effluent sample. Means are provided to periodically back flush each filter unit without shutting off the whole system.

  20. Fallon, Nevada FORGE Fluid Geochemistry

    DOE Data Explorer

    Blankenship, Doug; Ayling, Bridget

    2018-03-13

    Fluid geochemistry analysis for wells supporting the Fallon FORGE project. Samples were collected from geothermal wells using standard geothermal water sampling techniques, including filtration and acidification of the cation sample to pH < 2 prior to geochemical analysis. Analyses after 2005 were done in reputable commercial laboratories that follow standard protocols for aqueous chemistry analysis.

  1. Porcine reproductive and respiratory syndrome virus (PRRSV) surveillance using pre-weaning oral fluid samples detects circulation of wild-type PRRSV.

    PubMed

    Kittawornrat, Apisit; Panyasing, Yaowalak; Goodell, Christa; Wang, Chong; Gauger, Phillip; Harmon, Karen; Rauh, Rolf; Desfresne, Luc; Levis, Ian; Zimmerman, Jeffrey

    2014-01-31

    Oral fluid samples collected from litters of piglets (n=600) one day prior to weaning were evaluated as a method to surveil for porcine reproductive and respiratory syndrome virus (PRRSV) infections in four sow herds of approximately 12,500 sow each. Serum samples from the litters' dam (n=600) were included for comparison. All four herds were endemically infected with PRRSV and all sows had been vaccinated ≥ 2 times with PRRSV modified-live virus vaccines. After all specimens had been collected, samples were randomized and assayed by PRRSV real-time reverse transcription polymerase chain reaction (RT-qPCR) and four PRRSV antibody ELISA assays (IgM, IgA, IgG, and Commercial Kit). All sow serum samples were negative by PRRSV RT-qPCR, but 9 of 600 oral fluid samples tested positive at two laboratories. Open reading frame 5 (ORF5) sequencing of 2 of the 9 positive oral fluid samples identified wild-type viruses as the source of the infection. A comparison of antibody responses in RT-qPCR positive vs. negative oral fluid samples showed significantly higher IgG S/P ratios in RT-qPCR-positive oral fluid samples (mean S/P 3.46 vs. 2.36; p=0.02). Likewise, sow serum samples from RT-qPCR-positive litter oral fluid samples showed significantly higher serum IgG (mean S/P 1.73 vs. 0.98; p<0.001) and Commercial Kit (mean S/P 1.97 vs. 0.98; p<0.001) S/P ratios. Overall, the study showed that pre-weaning litter oral fluid samples could provide an efficient and sensitive approach to surveil for PRRSV in infected, vaccinated, or presumed-negative pig breeding herds. Copyright © 2014 Elsevier B.V. All rights reserved.

  2. Fluid and Electrolyte Needs for Training, Competition, and Recovery

    DTIC Science & Technology

    2011-01-01

    begin both training and competition in a state of fluid deficit. Analysis of samples collected from elite football ( soccer ) players before training...surprisingly, samples collected from players before a competitive game revealed that 8 of the 20 outfield players had a urine osmolality in excess of...2007) reported that basketball players attempted fewer shots and were less able to make shots linked with movement (e.g. lay-up) when dehydration had

  3. COLDEX-86: Fluid and Electrolyte Changes during Prolonged Cold Water Immersion

    DTIC Science & Technology

    1990-12-01

    4 Urine and blood collections .................. ..................... 5 Sample processing and biochemical analyses...and decaffeinated tea and coffee. Ingestion of fluids was encouraged. After completing the immersion, 16 oz of warm apple or cranberry juice was...day. Sample processing and biochemical analyses. Blood samples (25 ml) were drawn from an antecubital vein with minimum stasis. Each sample was divided

  4. Detection time for THC in oral fluid after frequent cannabis smoking.

    PubMed

    Andås, Hilde T; Krabseth, Hege-Merete; Enger, Asle; Marcussen, Bjarne N; Haneborg, An-Magritt; Christophersen, Asbjørg S; Vindenes, Vigdis; Øiestad, Elisabeth L

    2014-12-01

    The use of oral fluid for detecting drugs of abuse has become increasingly more frequent. Few studies have, however, investigated the detection times for drugs of abuse in oral fluid, compared with that of in urine or in blood. Cannabis is the world's most widely used drug of abuse, and the detection times for cannabis, in different types of matrixes, are therefore important information to the laboratories or institutions performing and evaluating drugs of abuse analyses. It is well known that frequent use of high dosages of cannabis, for longer periods of time, might lead to prolonged detection times for THC-COOH in urine. Cannabis intake is detected in oral fluid as THC, and a positive finding is considered to be a result of recent smoking, although some studies have already reported longer detection times. The aim of this study was to investigate the detection time for THC in oral fluid, collected from drug addicts admitted for detoxification. Findings in oral fluid were compared with findings in urine, among 26 patients admitted to a closed detoxification unit. The study, being the first in doing so, describes the concentration-time profiles for THC in oral fluid among chronic cannabis users, during monitored abstinence, using the Intercept collection kit. The study also includes the concentration-time profiles for creatinine-corrected THC-COOH ratios in urine samples, included to monitor for the possibility of new intakes. THC was detected in oral fluid collected from 11 of the 26 patients in the study. The elimination curves for THC in oral fluid revealed that negative samples could be interspersed among positive samples several days after cessation, whereas the THC-COOH concentrations in urine were decreasing. THC was, in this study, detected in oral fluid for up to 8 days after admission. The study shows that frequent use of high dosages of cannabis may lead to prolonged detection times, and that positive samples can be interspersed among negative samples. These results are of great importance when THC results from oral fluid analyses are to be interpreted.

  5. Portable Suction Lysimeter

    DOEpatents

    Hubbell, Joel M.; Sisson, James B.

    2004-07-13

    A portable lysimeter including a collection vessel having an inflatable bladder and a semi-permeable member assembly at least partially movable in response to inflation of the bladder, a sample conduit in fluid communication with the semi-permeable member and a reservoir in fluid communication with the sample conduit.

  6. Detection of porcine reproductive and respiratory syndrome virus (PRRSV) and influenza A virus (IAV) in oral fluid of pigs.

    PubMed

    Biernacka, Kinga; Karbowiak, Paweł; Wróbel, Paweł; Charęza, Tomasz; Czopowicz, Michał; Balka, Gyula; Goodell, Christa; Rauh, Rolf; Stadejek, Tomasz

    2016-12-01

    Recently oral fluid has become a novel sample type for pathogen nucleic acid and antibody detection, as it is easy to obtain with non-invasive procedures. The objective of the study was to analyze porcine reproductive and respiratory syndrome virus (PRRSV) and influenza A virus (IAV) circulation in growing pigs from three Polish production farms, using Real Time PCR and ELISA testing of oral fluid and serum. Oral fluids were collected every 2weeks, in the same 3-4 pens of pigs aged between 5 and 17weeks. Additionally, blood samples were collected every 4weeks from 4 pigs corresponding to the same pens as oral fluid and tested for the presence of PRRSV nucleic acid (pooled by 4) and antibodies. In farm A no PRRSV circulation was detected and only maternal antibodies were present. In farm B and farm C antibodies to PRRSV in serum and oral fluid were detected in most samples. In farm B PRRSV Type 1 was detected in 80.9% of oral fluid samples and in 58.3% of serum pools, and in farm C in 92.8% of oral fluid samples and 75% serum pools. Striking differences were observed between different pens in PRRSV detection patterns. In farms B and C ORF5 sequence analysis showed the presence of wild type strains which were about 84-85% identical to the modified live vaccine used. In all three farms two waves of IAV shedding with oral fluid were detected, in weaners and fatteners. Copyright © 2016 Elsevier Ltd. All rights reserved.

  7. 40 CFR 65.113 - Standards: Sampling connection systems.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... be collected or captured. (c) Equipment design and operation. Each closed-purge, closed-loop, or... system; or (2) Collect and recycle the purged process fluid to a process; or (3) Be designed and operated to capture and transport all the purged process fluid to a control device that meets the requirements...

  8. 40 CFR 65.113 - Standards: Sampling connection systems.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... be collected or captured. (c) Equipment design and operation. Each closed-purge, closed-loop, or... system; or (2) Collect and recycle the purged process fluid to a process; or (3) Be designed and operated to capture and transport all the purged process fluid to a control device that meets the requirements...

  9. 40 CFR 65.113 - Standards: Sampling connection systems.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... be collected or captured. (c) Equipment design and operation. Each closed-purge, closed-loop, or... system; or (2) Collect and recycle the purged process fluid to a process; or (3) Be designed and operated to capture and transport all the purged process fluid to a control device that meets the requirements...

  10. Partitioning of Metals Throughout a Winter Storm-Generated Fluid Mud Event, Atchafalaya Shelf, Louisiana

    NASA Astrophysics Data System (ADS)

    Clark, F. R.; McKee, B. A.; Duncan, D. D.

    2002-12-01

    Particulate and dissolved phases of a suite of metals and radionuclides were analyzed in fluid mud samples collected during a time series. This time series was taken during the passage of a winter storm on the Atchafalaya Shelf off the coast of Louisiana. The shelf receives an estimated 30% of the flow of the Mississippi River from its distributary, the Atchafalaya River. This input contributes a high sediment load to the shelf. Frequent winter storms provide shear stress to resuspend sediments and form fluid mud. Samples of fluid mud and overlying water were collected every two hours for 56 hours. Meteorological data as well as turbidity measurements by OBS were collected throughout the study. Bottom sediments were also collected before and after the time series. Partitioning effects were investigated on Be7, Th234, and Pb210 by gamma spectroscopy. These effects were also studied on several redox-sensitive metals, including Fe, Mn, Mo, Te, Re, U, Al, Ti, and V by ICP-MS analysis. Preliminary results indicate a rapid establishment of reducing conditions in fluid mud immediately overlying the seabed. These conditions persist until the suspended sediments in the fluid mud settle, and the fluid mud dissipates. The recurrence of storm front passages and their subsequent fluid mud formation cause repeated cycling from oxic to suboxic conditions in these coastal bottom waters. This redox cycling could potentially alter the fates of redox-sensitive metals, especially those associated with metal oxide carrier phases.

  11. The presence of vaginal Lactobacillus species does not contribute to a measureable difference in amniotic fluid lactate levels collected from the vaginal tract of laboring women.

    PubMed

    Hall, Beverley; Wong, Diana; Healy, Clare; Tracy, Mark B; Tracy, Sally K; Rawlinson, William D

    2017-04-01

    Amniotic fluid lactate research is based on the hypothesis that a relationship exists between fatigued uterine muscles and raised concentrations of the metabolite lactate, which is excreted into the amniotic fluid during labor. To assess potentially confounding effects of lactate-producing organisms on amniotic fluid lactate measurements, we aimed to determine if the presence of vaginal Lactobacillus species was associated with elevated levels of amniotic fluid lactate, measured from the vaginal tract of women in labor. Results from this study contribute to a large prospective longitudinal study of amniotic fluid lactate at a teaching hospital in Sydney, Australia. Amniotic fluid lactate measurement was assessed at the time of routine vaginal examination, after membranes had ruptured, using a hand-held lactate meter StatStripXPress (Nova Biomedical). Vaginal swab samples were collected at the time of the first amniotic fluid lactate measurement and stored for later detection and quantification of Lactobacillus species using a TaqMan real-time PCR assay. Swab sample and amniotic fluid lactate results were paired and analyzed. The PCR assay detected Lactobacillus species in 48 of 388 (12%) vaginal swab specimens (8% positive, 4% low positive) collected from women in labor after membranes had ruptured. There was no significant difference in median and mean (respectively) amniotic fluid lactate levels with (8.35 mmol/L; 8.95 mmol/L) or without (8.5 mmol/L; 9.08 mmol/L) Lactobacillus species detected. There was no association between the presence or level of vaginal Lactobacillus species and the measurement of amniotic fluid lactate collected from the vaginal tract of women during labor. © 2017 Nordic Federation of Societies of Obstetrics and Gynecology.

  12. A precision multi-sampler for deep-sea hydrothermal microbial mat studies

    NASA Astrophysics Data System (ADS)

    Breier, J. A.; Gomez-Ibanez, D.; Reddington, E.; Huber, J. A.; Emerson, D.

    2012-12-01

    A new tool was developed for deep-sea microbial mat studies by remotely operated vehicles and was successfully deployed during a cruise to the hydrothermal vent systems of the Mid-Cayman Rise. The Mat Sampler allows for discrete, controlled material collection from complex microbial structures, vertical-profiling within thick microbial mats and particulate and fluid sample collection from venting seafloor fluids. It has a reconfigurable and expandable sample capacity based on magazines of 6 syringes, filters, or water bottles. Multiple magazines can be used such that 12-36 samples can be collected routinely during a single dive; several times more if the dive is dedicated for this purpose. It is capable of hosting in situ physical, electrochemical, and optical sensors, including temperature and oxygen probes in order to guide sampling and to record critical environmental parameters at the time and point of sample collection. The precision sampling capability of this instrument will greatly enhance efforts to understand the structured, delicate, microbial mat communities that grow in diverse benthic habitats.

  13. Detection Times of Diazepam, Clonazepam, and Alprazolam in Oral Fluid Collected From Patients Admitted to Detoxification, After High and Repeated Drug Intake.

    PubMed

    Nordal, Kristin; Øiestad, Elisabeth L; Enger, Asle; Christophersen, Asbjorg S; Vindenes, Vigdis

    2015-08-01

    Clonazepam, diazepam, and alprazolam are benzodiazepines with sedative, anticonvulsant, and anxiolytic effects, but their prevalence in drug abuse and drug overdoses has long been recognized. When detection times for psychoactive drugs in oral fluid are reported, they are most often based on therapeutic doses administered in clinical studies. Repeated ingestions of high doses, as seen after drug abuse, are however likely to cause positive samples for extended time periods. Findings of drugs of abuse in oral fluid collected from imprisoned persons might lead to negative sanctions, and the knowledge of detection times of these drugs is thus important to ensure correct interpretation. The aim of this study was to investigate the time window of detection for diazepam, clonazepam, and alprazolam in oral fluid from drug addicts admitted to detoxification. Twenty-five patients with a history of heavy drug abuse admitted to a detoxification ward were included. Oral fluid was collected daily in the morning and the evening and urine samples every morning for 10 days, using the Intercept device. Whole blood samples were collected if the patient accepted. The cutoff levels in oral fluid were 1.3 ng/mL for diazepam, N-desmethyldiazepam, and 7-aminoclonazepam and 1 ng/mL for clonazepam and alprazolam. In urine, the cutoff levels for quantifications were 30 ng/mL for alprazolam, alpha-OH-alprazolam, and 7-aminoclonazepam, 135 ng/mL for N-desmethyldizepam, and 150 ng/mL for 3-OH-diazepam and for all the compounds, the cutoff for the screening analyses were 200 ng/mL. The maximum detection times for diazepam and N-desmethyldiazepam in oral fluid were 7 and 9 days, respectively. For clonazepam and 7-aminoclonazepam, the maximum detection times in oral fluid were 5 and 6 days, respectively. The maximum detection time for alprazolam in oral fluid was 2.5 days. New ingestions were not suspected in any of the cases, because the corresponding concentrations in urine were decreasing. Results from blood samples revealed that high doses of benzodiazepines had been ingested before admission, and explains the longer detection times in oral fluids than reported previously after intake of therapeutic doses of these drugs. This study has shown that oral fluid might be a viable alternative medium to urine when the abuse of benzodiazepines is suspected.

  14. Critical Elements in Produced Fluids from Nevada and Utah

    DOE Data Explorer

    Simmons, Stuart

    2017-07-27

    Critical elements and related analytical data for produced fluids from geothermal fields in Nevada and Utah, Sevier thermal belt hot springs, Utah, and Uinta basin oil-gas wells, Utah are reported. Analytical results include pH, major species, trace elements, transition metals, other metals, metalloids and REEs. Gas samples were collected and analyzed from Beowawe, Dixie Valley, Roosevelt Hot Springs, and Thermo. Helium gases and helium isotopes were analyzed on samples collected at Patua, San Emido and two wells in the Uinta basin.

  15. [Pre-analytical quality in fluid samples cytopathology: Results of a survey from the French Society of Clinical Cytology].

    PubMed

    Courtade-Saïdi, Monique; Fleury Feith, Jocelyne

    2015-10-01

    The pre-analytical step includes sample collection, preparation, transportation and storage in the pathology unit where the diagnosis is performed. The pathologist ensures that pre-analytical conditions are in line with expectations. The lack of standardization for handling cytological samples makes this pre-analytical step difficult to harmonize. Moreover, this step depends on the nature of the sample: fresh liquid or fixed material, air-dried smears, liquid-based cytology. The aim of the study was to review the different practices in French structures of pathology on the pre-analytical phase concerning cytological fluids such as broncho-alveolar lavage (BALF), serous fluids and urine. A survey was conducted on the basis of the pre-analytical chapter of the ISO 15189 and sent to 191 French pathological structures (105 public and 86 private). Fifty-six laboratories replied to the survey. Ninety-five per cent have a computerized management system and 70% a manual on sample handling. The general instructions requested for the patients and sample identification were highly correctly filled with a short time routing and additional tests prescription. By contrast, information are variable concerning the clinical information requested and the type of tubes for collecting fluids and the volumes required as well as the actions taken in case of non-conformity. For the specific items concerning BALF, serous fluids and urine, this survey has shown a great heterogeneity according to sample collection, fixation and of clinical information. This survey demonstrates that the pre-analytical quality for BALF, serous fluids and urine is not optimal and that some corrections of the practices are recommended with a standardization of numerous steps in order to increase the reproducibility of additional tests such as immunocytochemistry, cytogenetic and molecular biology. Some recommendations have been written. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  16. Evaluation of pyramid training as a method to increase diagnostic sampling capacity during an emergency veterinary response to a swine disease outbreak.

    PubMed

    Canon, Abbey J; Lauterbach, Nicholas; Bates, Jessica; Skoland, Kristin; Thomas, Paul; Ellingson, Josh; Ruston, Chelsea; Breuer, Mary; Gerardy, Kimberlee; Hershberger, Nicole; Hayman, Kristen; Buckley, Alexis; Holtkamp, Derald; Karriker, Locke

    2017-06-15

    OBJECTIVE To develop and evaluate a pyramid training method for teaching techniques for collection of diagnostic samples from swine. DESIGN Experimental trial. SAMPLE 45 veterinary students. PROCEDURES Participants went through a preinstruction assessment to determine their familiarity with the equipment needed and techniques used to collect samples of blood, nasal secretions, feces, and oral fluid from pigs. Participants were then shown a series of videos illustrating the correct equipment and techniques for collecting samples and were provided hands-on pyramid-based instruction wherein a single swine veterinarian trained 2 or 3 participants on each of the techniques and each of those participants, in turn, trained additional participants. Additional assessments were performed after the instruction was completed. RESULTS Following the instruction phase, percentages of participants able to collect adequate samples of blood, nasal secretions, feces, and oral fluid increased, as did scores on a written quiz assessing participants' ability to identify the correct equipment, positioning, and procedures for collection of samples. CONCLUSIONS AND CLINICAL RELEVANCE Results suggested that the pyramid training method may be a feasible way to rapidly increase diagnostic sampling capacity during an emergency veterinary response to a swine disease outbreak.

  17. White blood cell counting system

    NASA Technical Reports Server (NTRS)

    1972-01-01

    The design, fabrication, and tests of a prototype white blood cell counting system for use in the Skylab IMSS are presented. The counting system consists of a sample collection subsystem, sample dilution and fluid containment subsystem, and a cell counter. Preliminary test results show the sample collection and the dilution subsystems are functional and fulfill design goals. Results for the fluid containment subsystem show the handling bags cause counting errors due to: (1) adsorption of cells to the walls of the container, and (2) inadequate cleaning of the plastic bag material before fabrication. It was recommended that another bag material be selected.

  18. A Study on the Reliability of an On-Site Oral Fluid Drug Test in a Recreational Context

    PubMed Central

    Gentili, Stefano; Tittarelli, Roberta; Mannocchi, Giulio

    2016-01-01

    The reliability of DrugWipe 5A on site test for principal drugs of abuse (cannabis, amphetamines, cocaine, and opiates) detection in oral fluid was assessed by comparing the on-site results with headspace solid-phase microextraction (HS-SPME) gas chromatography-mass spectrometry (GC-MS) analysis on samples extracted by the device collection pad. Oral fluid samples were collected at recreational settings (e.g., discos, pubs, and music bars) of Rome metropolitan area. Eighty-three club goers underwent the on-site drug screening test with one device. Independently from the result obtained, a second device was used just to collect another oral fluid sample subsequently extracted and analyzed in the laboratory following HS-SPME procedure, gas chromatographic separation by a capillary column, and MS detection by electron impact ionization. DrugWipe 5A on-site test showed 54 samples (65.1%) positive to one or more drugs of abuse, whereas 75 samples (90.4%) tested positive for one or more substances following GC-MS assay. Comparing the obtained results, the device showed sensitivity, specificity, and accuracy around 80% for amphetamines class. Sensitivity (67 and 50%) was obtained for cocaine and opiates, while both sensitivity and accuracy were unsuccessful (29 and 53%, resp.) for cannabis, underlying the limitation of the device for this latter drug class. PMID:27610266

  19. Collection of Oral Fluids Using Cotton Ropes as a Sampling Method to Detect Foot-and-Mouth Disease Virus Infection in Pigs.

    PubMed

    Vosloo, W; Morris, J; Davis, A; Giles, M; Wang, J; Nguyen, H T T; Kim, P V; Quach, N V; Le, P T T; Nguyen, P H N; Dang, H; Tran, H X; Vu, P P; Hung, V V; Le, Q T; Tran, T M; Mai, T M T; Le, Q T V; Singanallur, N B

    2015-10-01

    In high-density farming practices, it is important to constantly monitor for infectious diseases, especially diseases that have the potential to spread rapidly between holdings. Pigs are known to amplify foot-and-mouth disease (FMD) by excreting large amounts of virus, and it is therefore important to detect the virus quickly and accurately to minimize the spread of disease. Ropes were used to collect oral fluid samples from pigs, and each sample was compared to saliva samples collected from individual animals by detecting FMD virus RNA using real-time PCR. Two different experiments are described where groups of pigs were infected with different serotypes of FMD virus, either with or without vaccination, and unvaccinated pigs were kept in aerosol contact. The sensitivity of the rope sampling varied between 0.67 and 0.92, and the statistical agreement between this method and individual sampling ranged from substantial to moderate for the two different serotypes. The ease of collecting oral fluids using ropes together with the high sensitivity of subsequent FMD detection through PCR indicates that this could be a useful method to monitor pig populations for FMD virus infection. With further validation of the sensitivity of detection of FMD virus RNA, this can be a cost-effective, non-invasive diagnostic tool. © 2013 Blackwell Verlag GmbH.

  20. Geochemistry of High Temperature Vent Fluids in Yellowstone Lake: Dissolved Carbon and Sulfur Concentrations and Isotopic Data

    NASA Astrophysics Data System (ADS)

    Cino, C.; Seyfried, W. E., Jr.; Tan, C.; Fu, Q.

    2017-12-01

    Yellowstone National Park is a dynamic environment home to an array of geysers, hot springs, and hydrothermal vents fueled by the underlying continental magmatic intrusion. Yellowstone Lake vent fluids accounts for approximately 10% of the total geothermal flux for all of Yellowstone National Park. Though studying this remote hydrothermal system poses severe challenges, it provides an excellent natural laboratory to research hydrothermal fluids that undergo higher pressure and temperature conditions in an environment largely shielded from atmospheric oxygen. The location of these vents also provides chemistry that is characteristic of fluids deeper in the Yellowstone hydrothermal system. In August 2016, hydrothermal fluids were collected from the Stevenson Island vents in collaboration with the Hydrothermal Dynamics of Yellowstone Lake (HD-YLAKE) project using novel sampling techniques and monitoring instrumentation. The newly built ROV Yogi was deployed to reach the vents in-situ with temperatures in excess of 151oC at 100-120 m depth, equipped with a 12-cylinder isobaric sampler to collect the hydrothermal fluids. Results from geochemical analyses indicate the fluids are rich in gases such as CO2, CH4, and H2S, with sample concentrations of approximately 12 mM, 161 μm, and 2.1 mM respectively. However, lake water mixing with the hydrothermal endmember fluid likely diluted these concentrations in the collected samples. Isotopic analyses indicate CO2 has a δ13C of -6 indicating magmatic origins, however the CH4 resulted in a δ13C of -65 which is in the biological range. This biogenic signature is likely due to the pyrolysis of immature organic matter in the lake bottom sediment, since the high temperatures measured for the fluids would not allow the presence of methanogens. H2S concentrations have not been previously measured for the hydrothermal fluids in Yellowstone Lake, and our vent fluid samples indicate significantly higher H2S concentrations than reported for subaerial vents. The cause of these measured high dissolved H2S concentrations in Yellowstone Lake may result from temperature and/or redox effects.

  1. Helium measurements of pore fluids obtained from the San Andreas Fault Observatory at Depth (SAFOD, USA) drill cores

    NASA Astrophysics Data System (ADS)

    Ali, S.; Stute, M.; Torgersen, T.; Winckler, G.; Kennedy, B. M.

    2011-02-01

    4He accumulated in fluids is a well established geochemical tracer used to study crustal fluid dynamics. Direct fluid samples are not always collectable; therefore, a method to extract rare gases from matrix fluids of whole rocks by diffusion has been adapted. Helium was measured on matrix fluids extracted from sandstones and mudstones recovered during the San Andreas Fault Observatory at Depth (SAFOD) drilling in California, USA. Samples were typically collected as subcores or from drillcore fragments. Helium concentration and isotope ratios were measured 4-6 times on each sample, and indicate a bulk 4He diffusion coefficient of 3.5 ± 1.3 × 10-8 cm2 s-1 at 21°C, compared to previously published diffusion coefficients of 1.2 × 10-18 cm2 s-1 (21°C) to 3.0 × 10-15 cm2 s-1 (150°C) in the sands and clays. Correcting the diffusion coefficient of 4Hewater for matrix porosity (˜3%) and tortuosity (˜6-13) produces effective diffusion coefficients of 1 × 10-8 cm2 s-1 (21°C) and 1 × 10-7 (120°C), effectively isolating pore fluid 4He from the 4He contained in the rock matrix. Model calculations indicate that <6% of helium initially dissolved in pore fluids was lost during the sampling process. Complete and quantitative extraction of the pore fluids provide minimum in situ porosity values for sandstones 2.8 ± 0.4% (SD, n = 4) and mudstones 3.1 ± 0.8% (SD, n = 4).

  2. Field and Lab-Based Microbiological Investigations of the Marcellus Shale

    NASA Astrophysics Data System (ADS)

    Wishart, J. R.; Neumann, K.; Edenborn, H. M.; Hakala, A.; Yang, J.; Torres, M. E.; Colwell, F. S.

    2013-12-01

    The recent exploration of shales for natural gas resources has provided the opportunity to study their subsurface geochemistry and microbiology. Evidence indicates that shale environments are marked by extreme conditions such as high temperature and pressure, low porosity, permeability and connectivity, and the presence of heavy metals and radionuclides. It has been postulated that many of these shales are naturally sterile due to the high pressure and temperature conditions under which they were formed. However, it has been shown in the Antrim and New Albany shales that microbial communities do exist in these environments. Here we review geochemical and microbiological evidence for the possible habitation of the Marcellus shale by microorganisms and compare these conditions to other shales in the U.S. Furthermore, we describe the development of sampling and analysis techniques used to evaluate microbial communities present in the Marcellus shale and associated hydraulic fracturing fluid. Sampling techniques thus far have consisted of collecting flowback fluids from wells and water impoundments and collecting core material from previous drilling expeditions. Furthermore, DNA extraction was performed on Marcellus shale sub-core with a MoBio PowerSoil kit to determine its efficiency. Assessment of the Marcellus shale indicates that it has low porosity and permeability that are not conducive to dense microbial populations; however, moderate temperatures and a natural fracture network may support a microbial community especially in zones where the Marcellus intersects more porous geologic formations. Also, hydraulic fracturing extends this fracture network providing more environments where microbial communities can exist. Previous research which collected flowback fluids has revealed a diverse microbial community that may be derived from hydrofrac fluid production or from the subsurface. DNA extraction from 10 g samples of Marcellus shale sub-core were unsuccessful even when samples were spiked with 8x108 cells/g of shale. This indicated that constituents of shale such as high levels of carbonates, humic acids and metals likely inhibited components of the PowerSoil kit. Future research is focused on refining sample collection and analyses to gain a full understanding of the microbiology of the Marcellus shale and associated flowback fluids. This includes the development of an in situ osmosampler, which will collect temporally relevant fluid and colonized substrate samples. The design of the osmosampler for hydraulic fracturing wells is being adapted from those used to sample marine environments. Furthermore, incubation experiments are underway to study interactions between microbial communities associated with hydraulic fracturing fluid and Marcellus shale samples. In conclusion, evidence suggests that the Marcellus shale is a possible component of the subsurface biosphere. Future studies will be valuable in determining the microbial community structure and function in relation to the geochemistry of the Marcellus shale and its future development as a natural gas resource.

  3. Simultaneous analysis of psychotropic phenylalkylamines in oral fluid by GC-MS with automated SPE and its application to legal cases.

    PubMed

    Choi, Hyeyoung; Baeck, Seungkyung; Jang, Moonhee; Lee, Sooyeun; Choi, Hwakyung; Chung, Heesun

    2012-02-10

    Phenylalkylamine derivatives, such as methamphetamine (MA), amphetamine (AM), 3,4-methylenedioxymethamphetamine (MDMA), 3,4-methylenedioxyamphetamine (MDA), phentermine (PT), fenfluramine (FFA) and phenmetrazine (PM), and ketamine (KT) are widely abused recreational or anorectic drugs in Korea and are regulated under the Controlled Substance Act in Korea. Phenylalkylamines and ketamine analysis is normally performed using both urine and hair samples but there is no established method for the simultaneous analysis of all these phenylalkylamines and ketamine in oral fluids. Oral fluid is easy to collect/handle and can provide an indication of recent drug abuse. In this study, to confirm the presence of phenylalkylamine derivatives and ketamine in oral fluid after screening with an immunoassay, an analytical method using automated solid phase extraction (SPE) and gas chromatography-mass spectrometry (GC-MS) was developed and fully validated according to international guidelines. The applicability of the assay was demonstrated by analyzing of authentic oral fluid samples and the results of oral fluid analysis were compared with those in urine and hair to to evaluate the feasibility of oral fluid in forensic cases. The recovery of phenylalkylamines and ketamine from oral fluid collection devices was also assessed. Oral fluid specimens from 23 drug abuse suspects submitted by the police were collected using Salivette (Sarstedt, Nümbrecht, Germany), Quantisal (Immunalysis, Pomona, CA) or direct expectoration. The samples were screened using a biochip array analyzer (Evidence Investigator, Randox, Antrim, UK). For confirmation, the samples were analyzed by GC-MS in selected-ion monitoring (SIM) mode after extraction using automated SPE (RapidTrace, Zymark, MA, USA) with a mixed-mode cation exchange cartridge (CLEAN SCREEN, 130 mg/3 ml, UCT, PA, USA) and derivatization with trifluoroacetic anhydride (TFA). The results from the immunoassay were consistent with those from GC-MS. Twenty oral fluid samples gave positive results for MA, AM, PT and/or PM among the 23 cases, which gave positive results in urine and/or hair. Although large variations in the MA, AM, PT and PM concentrations were observed in three different specimens, the oral fluid specimen was useful for demonstrating phenylalkylamines and ketamine abuse as an alternative specimen for urine. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  4. EFFECT OF URICOSURIC DRUG ADMINISTRATION ON URIC ACID LEVELS IN UNSTIMULATED PAROTID FLUID.

    DTIC Science & Technology

    Parotid fluid was collected twice daily without exogenous stimulation from 6 healthy young adult males, both before and during a 5-day period of...was found in parotid fluid uric acid concentration and uric acid secretion rate. The mean for serum uric acid decreased from 5.40 to 2.06 mg./100 ml...and parotid fluid uric acid concentration fell from 10.16 to 4.23 mg./100 ml. (morning samples) and 7.29 to 3.90 mg./100 ml. (afternoon samples). (Author)

  5. Oral fluid vs. Urine Analysis to Monitor Synthetic Cannabinoids and Classic Drugs Recent Exposure

    PubMed Central

    Blandino, Vincent; Wetzel, Jillian; Kim, Jiyoung; Haxhi, Petrit; Curtis, Richard; Concheiro, Marta

    2018-01-01

    Background Urine is a common biological sample to monitor recent drug exposure, and oral fluid is an alternative matrix of increasing interest in clinical and forensic toxicology. Limited data are available about oral fluid vs. urine drug disposition, especially for synthetic cannabinoids. Objective To compare urine and oral fluid as biological matrices to monitor recent drug exposure among HIV-infected homeless individuals. Methods Seventy matched urine and oral fluid samples were collected from 13 participants. Cannabis, amphetamines, benzodiazepines, cocaine and opiates were analyzed in urine by the enzyme-multiplied-immunoassay-technique and in oral fluid by liquid chromatography tandem mass spectrometry (LC-MSMS). Eleven synthetic cannabinoids were analyzed in urine and in oral fluid by LC-MSMS. Results Five oral fluid samples were positive for AB-FUBINACA. In urine, 4 samples tested positive for synthetic cannabinoids PB-22, 5-Fluoro-PB-22, AB-FUBINACA, and metabolites UR-144 5-pentanoic acid and UR-144 4-hydroxypentyl. In only one case, oral fluid and urine results matched, both specimens being AB-FUBINACA positive. For cannabis, 40 samples tested positive in urine and 30 in oral fluid (85.7% match). For cocaine, 37 urine and 52 oral fluid samples were positive (75.7% match). Twenty-four urine samples were positive for opiates, and 25 in oral fluid (81.4% match). For benzodiazepines, 23 samples were positive in urine and 25 in oral fluid (85.7% match). Conclusion/Discussion These results offer new information about drugs disposition between urine and oral fluid. Oral fluid is a good alternative matrix to urine for monitoring cannabis, cocaine, opiates and benzodiazepines recent use; however, synthetic cannabinoids showed mixed results. PMID:29173162

  6. Oral Fluid vs. Urine Analysis to Monitor Synthetic Cannabinoids and Classic Drugs Recent Exposure.

    PubMed

    Blandino, Vincent; Wetzel, Jillian; Kim, Jiyoung; Haxhi, Petrit; Curtis, Richard; Concheiro, Marta

    2017-01-01

    Urine is a common biological sample to monitor recent drug exposure, and oral fluid is an alternative matrix of increasing interest in clinical and forensic toxicology. Limited data are available about oral fluid vs. urine drug disposition, especially for synthetic cannabinoids. To compare urine and oral fluid as biological matrices to monitor recent drug exposure among HIV-infected homeless individuals. Seventy matched urine and oral fluid samples were collected from 13 participants. Cannabis, amphetamines, benzodiazepines, cocaine and opiates were analyzed in urine by the enzyme-multipliedimmunoassay- technique and in oral fluid by liquid chromatography tandem mass spectrometry (LCMSMS). Eleven synthetic cannabinoids were analyzed in urine and in oral fluid by LC-MSMS. Five oral fluid samples were positive for AB-FUBINACA. In urine, 4 samples tested positive for synthetic cannabinoids PB-22, 5-Fluoro-PB-22, AB-FUBINACA, and metabolites UR-144 5-pentanoic acid and UR-144 4-hydroxypentyl. In only one case, oral fluid and urine results matched, both specimens being AB-FUBINACA positive. For cannabis, 40 samples tested positive in urine and 30 in oral fluid (85.7% match). For cocaine, 37 urine and 52 oral fluid samples were positive (75.7% match). Twenty-four urine samples were positive for opiates, and 25 in oral fluid (81.4% match). For benzodiazepines, 23 samples were positive in urine and 25 in oral fluid (85.7% match). These results offer new information about drugs disposition between urine and oral fluid. Oral fluid is a good alternative matrix to urine for monitoring cannabis, cocaine, opiates and benzodiazepines recent use; however, synthetic cannabinoids showed mixed results. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  7. Identification and quantitation of phosphatidylethanols in oral fluid by liquid chromatography-tandem mass spectrometry.

    PubMed

    Ullah, Shahid; Helander, Anders; Beck, Olof

    2017-08-28

    Phosphatidylethanols (PEth) are formed from phosphatidylcholines and ethanol and are used as a specific and sensitive alcohol biomarker. An analytical method for analysis of PEth in oral fluid based on high-performance liquid chromatography coupled to a quadrupole tandem mass spectrometer (LC-MS/MS) was developed and validated and applied on samples collected from patients undergoing alcohol detoxification. A 200-μL aliquot of oral fluid, collected using the QuantisalTM device, was extracted with chloroform/methanol containing internal standard and subjected to LC-MS/MS analysis of three selected PEth forms (16:0/16:0, 16:0/18:1, and 16:0/18:2). Chromatographic separation was achieved on a UPLC BEH phenyl column, using a mobile phase consisting of acetonitrile and water containing 10 mmol/L ammonium hydrogen carbonate with 0.1% ammonia. The MS instrument was operated in negative electrospray ionization and selected reaction monitoring mode. The detection limit for PEth 16:0/16:0, 16:0/18:1, and 16:0/18:2 was ~0.1 ng/mL, and the extraction recoveries at 2.0 ng/mL were in the range of 99%-114%. Method linearity over a concentration range up to 200 ng/mL was ≥0.99. No significant deviation in results was observed in an analyte stability study of two different concentrations at two different temperatures over 3 months. In 35 oral fluid samples collected from patients undergoing alcohol detoxification, the highest concentration was observed for PEth 16:0/18:1 (Detected range, 0.51-55.3 ng/mL; mean, 8.5; median, 3.1). In addition, all three PEth forms were variably identified in a majority (63%) of the oral fluid samples. The PEth 16:0/18:1 values in oral fluid showed a weak positive correlation with the corresponding values in whole blood samples (r=0.50, p=0.026, n=20). The LC-MS/MS method could reliably detect and quantify PEth in oral fluid samples collected after alcohol exposure. The method was characterized by validation data with satisfactory recovery, sensitivity, accuracy, and imprecision, and applied for analysis of clinical samples. The results suggest that measurement of PEth in oral fluid can be used as a biomarker for alcohol consumption, and as such a non-invasive complement to analysis in blood. However, further studies are required to evaluate the test characteristics (e.g. sensitivity and half-life) in comparison with PEth in blood.

  8. Prenatal Exposure to Environmental Phenols: Concentrations in Amniotic Fluid and Variability in Urinary Concentrations during Pregnancy

    PubMed Central

    Wolff, Mary S.; Calafat, Antonia M.; Ye, Xiaoyun; Bausell, Rebecca; Meadows, Molly; Stone, Joanne; Slama, Rémy; Engel, Stephanie M.

    2013-01-01

    Background: Maternal urinary biomarkers are often used to assess fetal exposure to phenols and their precursors. Their effectiveness as a measure of exposure in epidemiological studies depends on their variability during pregnancy and their ability to accurately predict fetal exposure. Objectives: We assessed the relationship between urinary and amniotic fluid concentrations of nine environmental phenols, and the reproducibility of urinary concentrations, among pregnant women. Methods: Seventy-one women referred for amniocentesis were included. Maternal urine was collected at the time of the amniocentesis appointment and on two subsequent occasions. Urine and amniotic fluid were analyzed for 2,4- and 2,5-dichlorophenols, bisphenol A, benzophenone-3, triclosan, and methyl-, ethyl-, propyl-, and butylparabens using online solid phase extraction–high performance liquid chromatography–isotope dilution tandem mass spectrometry. Results: Only benzophenone-3 and propylparaben were detectable in more than half of the amniotic fluid samples; for these phenols, concentrations in amniotic fluid and maternal urine collected on the same day were positively correlated (ρ = 0.53 and 0.32, respectively). Other phenols were detected infrequently in amniotic fluid (e.g., bisphenol A was detected in only two samples). The intraclass correlation coefficients (ICCs) of urinary concentrations in samples from individual women ranged from 0.48 and 0.62 for all phenols except bisphenol A (ICC = 0.11). Conclusion: Amniotic fluid detection frequencies for most phenols were low. The reproducibility of urine measures was poor for bisphenol A, but good for the other phenols. Although a single sample may provide a reasonable estimate of exposure for some phenols, collecting multiple urine samples during pregnancy is an option to reduce exposure measurement error in studies regarding the effects of phenol prenatal exposure on health. Citation: Philippat C, Wolff MS, Calafat AM, Ye X, Bausell R, Meadows M, Stone J, Slama R, Engel SM. 2013. Prenatal exposure to environmental phenols: concentrations in amniotic fluid and variability in urinary concentrations during pregnancy. Environ Health Perspect 121:1225–1231; http://dx.doi.org/10.1289/ehp.1206335 PMID:23942273

  9. Collection and analysis of peritoneal fluid from healthy llamas and alpacas.

    PubMed

    Cebra, Christopher K; Tornquist, Susan J; Reed, Shannon K

    2008-05-01

    To describe a technique for abdominocentesis in camelids and report peritoneal fluid biochemical and cytologic findings from healthy llamas and alpacas. Prospective study. Animals-17 adult llamas and 5 adult alpacas. Right paracostal abdominocentesis was performed. Peritoneal fluid was collected by gravity flow into tubes containing potassium-EDTA for cell count and cytologic evaluation and lithium heparin for biochemical analysis. Blood samples were collected via jugular venipuncture into heparinized tubes at the same time. Cytologic components were quantified. Fluid pH and concentrations of total carbon dioxide, sodium, potassium, chloride, lactate, and glucose were compared between peritoneal fluid and venous blood. All but 3 camelids had peritoneal fluid cell counts of < 3,000 nucleated cells/microL, with < 2,000 neutrophils/microL and < 1,040 large mononuclear cells/microL. All but 1 had peritoneal fluid protein concentrations of > or = 2.5 g/dL. Peritoneal fluid of camelids generally contained slightly less glucose, lactate, and sodium and roughly equal concentrations of potassium and chloride as venous blood. Peritoneal fluid was collected safely from healthy camelids. Compared with blood, peritoneal fluid usually had a low cell count and protein concentration, but some individuals had higher values. Electrolyte concentrations resembled those found in blood. High cell counts and protein concentrations found in peritoneal fluid of some healthy camelids may overlap with values found in diseased camelids, complicating interpretation of peritoneal fluid values.

  10. Salivary flow and alpha-amylase: collection technique, duration, and oral fluid type.

    PubMed

    Beltzer, Emilie K; Fortunato, Christine K; Guaderrama, Melissa M; Peckins, Melissa K; Garramone, Bianca M; Granger, Douglas A

    2010-09-01

    There has been renewed interest in salivary alpha-amylase (sAA), a surrogate marker of autonomic/sympathetic activity, in biosocial research on stress vulnerability, reactivity, and recovery. This study explored the impact of saliva flow rate on sAA measurement by examining the influence of (1) the technique used to collect oral fluid-synthetic swab, cotton pledget, hydrocellulose microsponge, or passive drool; (2) collection point duration--the length of time the technique is employed (1-5min); and (3) oral fluid type--whole unstimulated saliva (not absorbed by any material) or oral fluid sampled from areas near the parotid, submandibular, or sublingual salivary glands. sAA activity (U/mL) was the highest in oral fluid collected from the parotid and submandibular gland areas. The volume (mL) of oral fluid collected increased, and the activity of sAA (U/mL) decreased, as collection point duration lengthened. The magnitude of these effects varied according to collection technique and oral fluid type. Across all conditions, there were positive correlations (range .70-.88) between sAA activity (U/mL) and sAA output (U/min). Management of these potential sources of measurement error will be essential to ensuring the success of future research on the correlates and concomitants of sAA activity, stress-related reactivity and recovery, and diurnal variation. Copyright 2010 Elsevier Inc. All rights reserved.

  11. Detection and follow-up of torque teno midi virus ("small anelloviruses") in nasopharyngeal aspirates and three other human body fluids in children.

    PubMed

    Burián, Zsófia; Szabó, Hajnalka; Székely, Gyöngyi; Gyurkovits, Kálmán; Pankovics, Péter; Farkas, Tibor; Reuter, Gábor

    2011-09-01

    Torque teno midi virus/small anellovirus (TTMDV/SAV) is a member of the family Anelloviridae. It has a single-stranded, circular, negative-sense DNA genome. Its pathogenic role in human disease remains to be confirmed. In this study, viral shedding, molecular epidemiology and genetic diversity of TTMDV/SAV were studied in human body fluids. Nasopharyngeal aspirates collected from children with acute respiratory disease were tested by PCR/nested PCR for TTMDV/SAV in two seasons (2005/2006, 2006/2007). Two years later, additional urine, stool, and serum samples and nasopharyngeal aspirates were collected from eight symptomless children for follow-up investigation. Forty-three (46.7%) of the 92 nasopharyngeal aspirates collected contained TTMDV/SAV. High genetic diversity was observed; however, identical sequences were also detected in two patients. The mean age of the infected children was 3 years (1 months-8 years), and 58% of them were female. Co-infection with RSV was detected in 23% of the samples. In a follow-up study, nasopharyngeal aspirates and serum of six (75%), stool samples of four (50%) and urine samples of two (25%) of the eight children were anellovirus-positive. None of the anellovirus sequences were identical in the two collection periods, but identical sequences were detected in different body fluids collected at the same time from the same child. TTMDV/SAVs shedding was detected in four human body fluids. As a consequence, it is possible that generalized infection and fecal/uro-oral transmission of TTMDV/SAV occur. TTMDV/SAVs are frequently present in nasopharyngeal aspirates, although the variants may only be transient agents. Further research is needed to investigate the pathogenesis and pathogenic role of TTMDV/SAV.

  12. Characterization of long-term elution of platinum from carboplatin-impregnated calcium sulfate hemihydrate beads in vitro by two distinct sample collection methods.

    PubMed

    Tulipan, Rachel J; Phillips, Heidi; Garrett, Laura D; Dirikolu, Levent; Mitchell, Mark A

    2017-05-01

    OBJECTIVE To characterize long-term elution of platinum from carboplatin-impregnated calcium sulfate hemihydrate (CI-CSH) beads in vitro by comparing 2 distinct sample collection methods designed to mimic 2 in vivo environments. SAMPLES 162 CI-CSH beads containing 4.6 mg of carboplatin (2.4 mg of platinum/bead). PROCEDURES For method 1, which mimicked an in vivo environment with rapid and complete fluid exchange, each of 3 plastic 10-mL conical tubes contained 3 CI-CSH beads and 5 mL of PBS solution. Eluent samples were obtained by evacuation of all fluid at 1, 2, 3, 6, 9, and 12 hours and 1, 2, 3, 6, 9, 12, 15, 18, 22, 26, and 30 days. Five milliliters of fresh PBS solution was then added to each tube. For method 2, which mimicked an in vivo environment with no fluid exchange, each of 51 tubes (ie, 3 tubes/17 sample collection times) contained 3 CI-CSH beads and 5 mL of PBS solution. Eluent samples were obtained from the assigned tubes for each time point. All samples were analyzed for platinum content by inductively coupled plasma-mass spectrometry. RESULTS Platinum was released from CI-CSH beads for 22 to 30 days. Significant differences were found in platinum concentration and percentage of platinum eluted from CI-CSH beads over time for each method. Platinum concentrations and elution percentages in method 2 samples were significantly higher than those of method 1 samples, except for the first hour measurements. CONCLUSIONS AND CLINICAL RELEVANCE Sample collection methods 1 and 2 may provide estimates of the minimum and maximum platinum release, respectively, from CI-CSH beads in vivo.

  13. Assessment of the use of oral fluid as a matrix for drug monitoring in patients undergoing treatment for opioid addiction.

    PubMed

    Kunkel, Frank; Fey, Elizabeth; Borg, Damon; Stripp, Richard; Getto, Christine

    2015-01-01

    Drug testing is an important clinical tool that is available to physicians who are assessing the effectiveness of drug treatment as well as patient compliance to the administered program. While urine has traditionally been the matrix of choice for drug monitoring, oral fluid, a filtrate of the blood, has shown great promise as an alternative matrix for such applications. Oral fluid collection can be accomplished without the need for highly trained medical staff through the use of a simple, noninvasive oral fluid collection device, which obtains an adequate sample in only a few minutes. There has been a significant amount of research performed on the use of oral fluid for forensic toxicology application; however, more studies assessing the use of oral fluid drug testing are required to validate its ability to achieve clinical drug monitoring goals. Testing for various drugs in oral fluid may yield a different result when compared to the same drugs in urine, requiring an assessment of the utility of oral fluid for such practices. The purpose of this study was to examine the application of oral fluid drug testing in patients undergoing buprenorphine treatment for opioid dependence. A retrospective analysis of drug testing results obtained from 6,928 patients (4,560 unobserved urine collections and 2,368 observed oral fluid collections) monitored for heroin metabolite, amphetamine, benzodiazepines, buprenorphine, tetrahydrocannabinol, cocaine, codeine, hydrocodone, hydromorphone, methadone, morphine, oxycodone, and oxymorphone was completed. Results of this statistical exercise indicated that patients undergoing observed oral fluid collection tested positive more frequently than those unobserved urine collections for several illicit drugs and prescription medications targeted. Oral fluid was shown to detect illicit drug use as well as noncompliance in this patient population under the studied conditions more often than the urine specimens.

  14. PAROTID FLUID TOTAL PROTEIN IN PATIENTS WITH UREMIA AND PROTEINURIA.

    DTIC Science & Technology

    Stimulated parotid fluid samples (238) were collected from 32 patients to determine if altered renal function was associated with deviations in...tubular necrosis, and 15 had normal renal function. There were no significant differences in parotid fluid protein concentration or minute secretion associated with the state of renal function. (Author)

  15. 40 CFR 63.166 - Standards: Sampling connection systems.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... fluid to a process; or (3) Be designed and operated to capture and transport the purged process fluid to a control device that complies with the requirements of § 63.172 of this subpart; or (4) Collect... of subpart G of this part applicable to group 1 wastewater streams. If the purged process fluid does...

  16. 40 CFR 63.166 - Standards: Sampling connection systems.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... fluid to a process; or (3) Be designed and operated to capture and transport the purged process fluid to a control device that complies with the requirements of § 63.172 of this subpart; or (4) Collect... of subpart G of this part applicable to group 1 wastewater streams. If the purged process fluid does...

  17. Interrogation cradle and insertable containment fixture for detecting birefringent microcrystals in bile

    DOEpatents

    Darrow, Chris; Seger, Tino

    2003-09-30

    A transparent flow channel fluidly communicates a fluid source and a collection reservoir. An interrogating light beam passes through a first polarizer having a first plane of polarization. The flow channel is orthogonal to the light beam. The light beam passes through a fluid sample as it flows through the flow channel, and is then filtered through a second polarizer having a second plane of polarization rotated 90.degree. from the first plane of polarization. An electronic photo-detector is aligned with the light beam, and signals the presence of birefringent microcrystals in the fluid sample by generating voltage pulses. A disposable containment fixture includes the flow channel and the collection reservoir. The fixture is adapted for removable insertion into an interrogation cradle that includes optical and data processing components. The cradle rigidly positions the centerline of the flow channel orthogonal to the light beam.

  18. Screening portal, system and method of using same

    DOEpatents

    Linker, Kevin L.; Hunter, John A.; Brusseau, Charles A.

    2013-04-30

    A portal, system and method for screening an object for a target substance is provided. The portal includes an inflatable bladder expandable to form a test space for receiving the object and a plurality of nozzles positioned about the inflatable bladder. The nozzles are in fluid communication with a fluid source for directing air over the object whereby samples are removed from the object for examination. A collector is operatively connected to the inflatable bladder for collecting the samples removed from the object. A detector is operatively connected to the collector for examining the removed samples for the presence of the target substance. At least one preconcentrator may be operatively connected to the collector for concentrating the samples collected thereby.

  19. Passive cannabis smoke exposure and oral fluid testing.

    PubMed

    Niedbala, Sam; Kardos, Keith; Salamone, Sal; Fritch, Dean; Bronsgeest, Matth; Cone, Edward J

    2004-10-01

    Oral fluid testing for Delta(9)-tetrahydrocannabinol (THC) provides a convenient means of detection of recent cannabis usage. In this study, the risk of positive oral fluid tests from passive cannabis smoke exposure was investigated by housing four cannabis-free volunteers in a small, unventilated, and sealed room with an approximate volume of 36 m(3). Five active cannabis smokers were also present in the room, and each smoked a single cannabis cigarette (1.75% THC). Cannabis smoking occurred over the first 20 min of the study session. All subjects remained in the room for approximately 4 h. Oral fluid specimens were collected with the Intercept DOA Oral Specimen Collection Device. Three urine specimens were collected (0, 20, and 245 min). In addition, three air samples were collected for measurement of THC content. All oral fluid specimens were screened by enzyme immunoassay (EIA) for cannabinoids (cutoff concentration = 3 ng/mL) and tested by gas chromatography-tandem mass spectrometry (GC-MS-MS) for THC (LOQ/LOD = 0.75 ng/mL). All urine specimens were screened by EIA for cannabinoids (cutoff concentration = 50 ng/mL) and tested by GC-MS-MS for THCCOOH (LOQ/LOD = 1 ng/mL). Air samples were measured for THC by GC-MS (LOD = 1 ng/L). A total of eight oral fluid specimens (collected 20 to 50 min following initiation of smoking) from the four passive subjects screened and confirmed positive for THC at concentrations ranging from 3.6 to 26.4 ng/mL. Two additional specimens from one passive subject, collected at 50 and 65 min, screened negative but contained THC in concentrations of 4.2 and 1.1 ng/mL, respectively. All subsequent specimens for passive participants tested negative by EIA and GC-MS-MS for the remainder of the 4-h session. In contrast, oral fluid specimens collected from the five cannabis smokers generally screened and confirmed positive for THC throughout the session at concentrations substantially higher than observed for passive subjects. Urine specimens from active cannabis smokers also screened and confirmed positive at conventional cutoff concentrations. A biphasic pattern of decline for THC was observed in oral fluid specimens collected from cannabis smokers, whereas a linear decline was seen for passive subjects suggesting that initial oral fluid contamination is cleared rapidly and is followed by THC sequestration in the oral mucosa. It is concluded that the risk of positive oral fluid tests from passive cannabis smoke inhalation is limited to a period of approximately 30 min following exposure.

  20. Archaeal Viruses Contribute to the Novel Viral Assemblage Inhabiting Oceanic, Basalt-Hosted Deep Subsurface Crustal Fluids

    NASA Astrophysics Data System (ADS)

    Nigro, O. D.; Rappe, M. S.; Jungbluth, S.; Lin, H. T.; Steward, G.

    2015-12-01

    Fluids contained in the basalt-hosted deep subsurface of the world's oceans represent one of the most inaccessible and understudied biospheres on earth. Recent improvements in sampling infrastructure have allowed us to collect large volumes of crustal fluids (~104 L) from Circulation Obviation Retrofit Kits (CORKs) placed in boreholes located on the eastern flank of the Juan de Fuca Ridge (JdFR). We detected viruses within these fluids by TEM and epifluorescence microscopy in samples collected from 2010 to 2014. Viral abundance, determined by epifluorescence counts, indicated that concentrations of viruses in subsurface basement fluids (~105 ml-1) are lower than the overlying seawater, but are higher in abundance than microbial cells in the same samples. Analysis of TEM images revealed distinct viral morphologies (rod and spindle-shaped) that resemble the morphologies of viral families infecting archaea. There are very few, if any, direct observations of these viral morphologies in marine samples, although they have been observed in enrichment cultures and their signature genes detected in metagenomic studies from hydrothermal vents and marine sediments. Analysis of metagenomes from the JdFR crustal fluids revealed sequences with homology to archaeal viruses from the rudiviridae, bicaudaviridae and fuselloviridae. Prokaryotic communities in fluids percolating through the basaltic basement rock of the JdFR flank are distinct from those inhabiting the overlying sediments and seawater. Similarly, our data support the idea that the viral assemblage in these fluids is distinct from viral assemblages in other marine and terrestrial aquatic environments. Our data also suggest that viruses contribute to the mortality of deep subsurface prokaryotes through cell lysis, and viruses may alter the genetic potential of their hosts through the processes of lysogenic conversion and horizontal gene transfer.

  1. Influence of Sampling on the Determination of Warfarin and Warfarin Alcohols in Oral Fluid

    PubMed Central

    Lomonaco, Tommaso; Ghimenti, Silvia; Piga, Isabella; Biagini, Denise; Onor, Massimo; Fuoco, Roger; Di Francesco, Fabio

    2014-01-01

    Background and Objective The determination of warfarin, RS/SR- and RR/SS-warfarin alcohols in oral fluid may offer additional information to the INR assay. This study aimed to establish an optimized sampling technique providing the best correlation between the oral fluid and the unbound plasma concentrations of these compounds. Materials and Methods Samples of non-stimulated and stimulated oral fluid, and blood were collected from 14 patients undergoing warfarin therapy. After acidification, analytes were extracted with a dichloromethane/hexane mixture and determined by HPLC with fluorescence detection. Plasma samples were also ultrafiltered for the determination of the unbound fraction. The chromatographic separation was carried out in isocratic conditions with a phosphate buffer/methanol mobile phase on a C-18 reversed-phase column. The absence of interfering compounds was verified by HPLC-ESI-Q-TOF. Results Stimulation generally increased the oral fluid pH to values close to blood pH in about 6 minutes. The concentration of warfarin and RS/SR-warfarin alcohols in oral fluid followed the same trend, whereas the concentration of RR/SS-warfarin alcohols was not affected. Six minute stimulation with chewing gum followed by collection with a polyester swab was the best sampling procedure, with a good repeatability (RSD <10%) and relatively low inter-subject variability (RSD  = 30%) of the oral fluid to plasma ratio. This procedure provided strong correlations between the measured oral fluid and unbound plasma concentration of warfarin (r  =  0.92, p <0.001) and RS/SR-warfarin alcohols (r  =  0.84, p <0.001), as well as between stimulated oral fluid and total plasma concentration of warfarin (r  =  0.78, p <0.001) and RS/SR-warfarin alcohols (r  =  0.81, p <0.001). Conclusion The very good correlation between oral fluid and unbound plasma concentration of warfarin and RS/SR-warfarin alcohols suggests that oral fluid analysis could provide clinically useful information for the monitoring of anticoagulant therapy, complementary to the INR assay. PMID:25478864

  2. Optimal probes for withdrawal of uncontaminated fluid samples

    NASA Astrophysics Data System (ADS)

    Sherwood, J. D.

    2005-08-01

    Withdrawal of fluid by a composite probe pushed against the face z =0 of a porous half-space z >0 is modeled assuming incompressible Darcy flow. The probe is circular, of radius a, with an inner sampling section of radius αa and a concentric outer guard probe αa βa is saturated with fluid 2; the two fluids have the same viscosity. It is assumed that the interface between the two fluids is sharp and remains so as it moves through the rock. The pressure in the probe is lower than that of the pore fluid in the rock, so that the fluid interface is convected with the fluids towards the probe. This idealized axisymmetric problem is solved numerically, and it is shown that an analysis based on far-field spherical flow towards a point sink is a good approximation when the nondimensional depth of fluid 1 is large, i.e., β ≫1. The inner sampling probe eventually produces pure fluid 2, and this technique has been proposed for sampling pore fluids in rock surrounding an oil well [A. Hrametz, C. Gardner, M. Wais, and M. Proett, U.S. Patent No. 6,301,959 B1 (16 October 2001)]. Fluid 1 is drilling fluid filtrate, which has displaced the original pore fluid (fluid 2), a pure sample of which is required. The time required to collect an uncontaminated sample of original pore fluid can be minimized by a suitable choice of the probe geometry α [J. Sherwood, J. Fitzgerald and B. Hill, U.S. Patent No. 6,719,049 B2 (13 April 2004)]. It is shown that the optimal choice of α depends on the depth of filtrate invasion β and the volume of sample required.

  3. Detection of total and PRRSV-specific antibodies in oral fluids collected with different rope types from PRRSV-vaccinated and experimentally infected pigs.

    PubMed

    Decorte, Inge; Van Breedam, Wander; Van der Stede, Yves; Nauwynck, Hans J; De Regge, Nick; Cay, Ann Brigitte

    2014-06-17

    Oral fluid collected by means of ropes has the potential to replace serum for monitoring and surveillance of important swine pathogens. Until now, the most commonly used method to collect oral fluid is by hanging a cotton rope in a pen. However, concerns about the influence of rope material on subsequent immunological assays have been raised. In this study, we evaluated six different rope materials for the collection of oral fluid and the subsequent detection of total and PRRSV-specific antibodies of different isotypes in oral fluid collected from PRRSV-vaccinated and infected pigs. An initial experiment showed that IgA is the predominant antibody isotype in porcine saliva. Moreover, it was found that synthetic ropes may yield higher amounts of IgA, whereas all rope types seemed to be equally suitable for IgG collection. Although IgA is the predominant antibody isotype in porcine oral fluid, the PRRSV-specific IgA-based IPMA and ELISA tests were clearly not ideal for sensitive detection of PRRSV-specific IgA antibodies. In contrast, PRRSV-specific IgG in oral fluids was readily detected in PRRSV-specific IgG-based IPMA and ELISA tests, indicating that IgG is a more reliable isotype for monitoring PRRSV-specific antibody immunity in vaccinated/infected animals via oral fluids with the currently available tests. Since PRRSV-specific IgG detection seems more reliable than PRRSV-specific IgA detection for monitoring PRRSV-specific antibody immunity via oral fluids, and since all rope types yield equal amounts of IgG, it seems that the currently used cotton ropes are an appropriate choice for sample collection in PRRSV monitoring.

  4. Rare earth element content of thermal fluids from Surprise Valley, California

    DOE Data Explorer

    Andrew Fowler

    2015-09-23

    Rare earth element measurements for thermal fluids from Surprise Valley, California. Samples were collected in acid washed HDPE bottles and acidified with concentrated trace element clean (Fisher Scientific) nitric acid. Samples were pre-concentratated by a factor of approximately 10 using chelating resin with and IDA functional group and measured on magnetic sector ICP-MS. Samples include Seyferth Hot Springs, Surprise Valley Resort Mineral Well, Leonard's Hot Spring, and Lake City Mud Volcano Boiling Spring.

  5. Evaluation of geophysical logs, Phase II, November 1998 to May 1999, at Crossley Farms Superfund Site, Berks County, Pennsylvania

    USGS Publications Warehouse

    Conger, Randall W.

    2000-01-01

    Between November 1998 and May 1999, geophysical logging was conducted in 29 boreholes at the Crossley Farms Superfund Site, Hereford Township, Berks County, Pa., to determine the fluidproducing zones, fluid-receiving zones, zones of vertical borehole flow, and casing depth. The wells range in depth from 96 to 500 feet below land surface. Gamma logs only were collected in three bedrock wells. The geophysical logging determined the placement of well screens and packers, which allow monitoring and sampling of water-bearing zones in the fractured bedrock so that the horizontal and vertical distribution of contaminated ground water migrating from known sources could be determined. Geophysical logging included collection of caliper, video, fluid-temperature, fluid-resistivity, single-point-resistance, natural-gamma, fluid-flow, and acoustic-televiewer logs. Caliper and video logs were used to locate fractures, joints, and weathered zones. Inflections on fluidtemperature and fluid-resistivity logs indicated possible water-bearing fractures, and flowmeter measurements verified these locations. Single-point-resistance and natural-gamma logs provided information on stratigraphy. After interpretation of geophysical, video logs, and drillers notes, 24 of the wells were reconstructed such that water levels can be monitored and water samples collected from discrete water-bearing fractures in each well.

  6. Release of mineral ions in dental plaque following acid production.

    PubMed

    Tanaka, M; Margolis, H C

    1999-03-01

    The release of appreciable amounts of calcium, phosphate and fluoride found in whole plaque into the plaque-fluid phase, following bacterial acid production, can potentially reduce the driving force for tooth demineralization. However, limited information is available on this topic, particularly on the release of fluoride. This study sought to determine the change in calcium, phosphate and fluoride concentrations in plaque fluid after sucrose exposure. 48 h overnight-fasted supragingival plaque samples were collected from all tooth surfaces (with the exception of the lower lingual anterior teeth) of one half of an individual mouth, following a 1 min water rinse. Plaque samples were then collected from the other half of the same mouth, following a 292 mM sucrose rinse. Plaque fluid was isolated by centrifugation and analysed for total calcium and phosphate (ion chromatography) and for free fluoride (ion-specific electrode). Samples were collected from seven individuals. Following sucrose exposure, plaque-fluid pH decreased significantly from 6.5+/- 0.3 to 5.4+/-0.2; calcium concentrations (mmol/l) also increased significantly (p < 0.01) from 1.9+/-0.5 to 5.0+/-2.1. Fluoride and phosphate concentrations in plaque fluid, however, did not increase significantly after sucrose exposure: mean concentrations (mmol/l) of fluoride after the water and sucrose rinses were 0.006+/-0.003 and 0.005+/-0.002, respectively, and mean phosphate concentrations (mmol/l) were 11.0+/-2.0 and 12.0+/-3.0, respectively. When results were expressed per wet plaque weight, phosphate concentrations were also found to increase significantly. The same trends were observed when additional plaque samples were treated in vitro with sucrose: fluoride-ion activity did not increase in plaque under in vivo-like conditions.

  7. 28 CFR 28.11 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Administration DEPARTMENT OF JUSTICE DNA IDENTIFICATION SYSTEM DNA Sample Collection, Analysis, and Indexing § 28.11 Definitions. DNA analysis means analysis of the deoxyribonucleic acid (DNA) identification information in a bodily sample. DNA sample means a tissue, fluid, or other bodily sample of an individual on...

  8. 28 CFR 28.11 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Administration DEPARTMENT OF JUSTICE DNA IDENTIFICATION SYSTEM DNA Sample Collection, Analysis, and Indexing § 28.11 Definitions. DNA analysis means analysis of the deoxyribonucleic acid (DNA) identification information in a bodily sample. DNA sample means a tissue, fluid, or other bodily sample of an individual on...

  9. 28 CFR 28.11 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Administration DEPARTMENT OF JUSTICE DNA IDENTIFICATION SYSTEM DNA Sample Collection, Analysis, and Indexing § 28.11 Definitions. DNA analysis means analysis of the deoxyribonucleic acid (DNA) identification information in a bodily sample. DNA sample means a tissue, fluid, or other bodily sample of an individual on...

  10. 28 CFR 28.11 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Administration DEPARTMENT OF JUSTICE DNA IDENTIFICATION SYSTEM DNA Sample Collection, Analysis, and Indexing § 28.11 Definitions. DNA analysis means analysis of the deoxyribonucleic acid (DNA) identification information in a bodily sample. DNA sample means a tissue, fluid, or other bodily sample of an individual on...

  11. 28 CFR 28.11 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Administration DEPARTMENT OF JUSTICE DNA IDENTIFICATION SYSTEM DNA Sample Collection, Analysis, and Indexing § 28.11 Definitions. DNA analysis means analysis of the deoxyribonucleic acid (DNA) identification information in a bodily sample. DNA sample means a tissue, fluid, or other bodily sample of an individual on...

  12. Noble Gas signatures of Enhanced Oil Recovery

    NASA Astrophysics Data System (ADS)

    Barry, P. H.; Kulongoski, J. T.; Tyne, R. L.; Hillegonds, D.; Byrne, D. J.; Landon, M. K.; Ballentine, C. J.

    2017-12-01

    Noble gases are powerful tracers of fluids from various oil and gas production activities in hydrocarbon reservoirs and nearby groundwater. Non-radiogenic noble gases are introduced into undisturbed oil and natural gas reservoirs through exchange with formation waters [1-3]. Reservoirs with extensive hydraulic fracturing, injection for enhanced oil recovery (EOR), and/or waste disposal also show evidence for a component of noble gases introduced from air [4]. Isotopic and elemental ratios of noble gases can be used to 1) assess the migration history of the injected and formation fluids, and 2) determine the extent of exchange between multiphase fluids in different reservoirs. We present noble gas isotope and abundance data from casing, separator and injectate gases of the Lost Hills and Fruitvale oil fields in the San Joaquin basin, California. Samples were collected as part of the California State Water Resource Control Board's Oil and Gas Regional Groundwater Monitoring Program. Lost Hills (n=7) and Fruitvale (n=2) gases are geochemically distinct and duplicate samples are highly reproducible. Lost Hills casing gas samples were collected from areas where EOR and hydraulic fracturing has occurred in the past several years, and from areas where EOR is absent. The Fruitvale samples were collected from a re-injection port. All samples are radiogenic in their He isotopes, typical of a crustal environment, and show enrichments in heavy noble gases, resulting from preferential adsorption on sediments. Fruitvale samples reflect air-like surface conditions, with higher air-derived noble gas concentrations. Lost Hills gases show a gradation from pristine crustal signatures - indicative of closed-system exchange with formation fluids - to strongly air-contaminated signatures in the EOR region. Pristine samples can be used to determine the extent of hydrocarbon exchange with fluids, whereas samples with excess air can be used to quantify the extent of EOR. Determining noble gas baseline values for pristine vs. recently modified (EOR, hydraulic fracturing) zones will be critical for interpreting the origin of any fugitive gases identified in nearby aquifers. [1] Ballentine et al., (1996) GCA, 60, 831-849 [2] Barry et al., (2016) GCA, 194, 291-309. [3] Barry et al., (2017) Geology, 45, 9. Darrah et al., (2014) PNAS 111, 39.

  13. β-trace protein as a diagnostic marker for perilymphatic fluid fistula: a prospective controlled pilot study to test a sample collection technique.

    PubMed

    Bachmann-Harildstad, Gregor; Stenklev, Niels Christian; Myrvoll, Elin; Jablonski, Greg; Klingenberg, Olav

    2011-01-01

    The diagnosis of perilymphatic fluid (PLF) fistula is still challenging. Perilymphatic fluid fistula is one possible complication after stapedotomy or cochlear implant surgery. We have performed a prospective diagnostic pilot study to further investigate β-trace protein (β-TP) as a marker for PLF fistula. In this pilot study, we tested the sensitivity of the β-TP marker using a simple method for sample collection from the tympanic cavity. Prospective controlled diagnostic study. Two-center tertiary referral hospitals. A total of 35 adult patients undergoing ear surgery were included. Subjects were divided into 2 groups: 1) 19 patients undergoing stapedotomy were investigated for PLF fistula in samples obtained from the tympanic cavity and 2) 16 patients undergoing myringoplasty were investigated for PLF fistula in samples from the tympanic cavity. This group served as the control. Mean age +/- SD at surgery was 49.9 +/- 8.0 years in the study group and 39.69 +/- 15.47 years in the control group. β-Trace protein (prostaglandin D synthase) in tympanic cavity samples and serum samples was analyzed. The samples were collected by gradually filling the tympanic cavity with 100 to 200 μl sodium chloride and by immediately collecting a volume of 60 to 100 μl in a mucus specimen set container. The concentration of β-TP was quantified using laser nephelometry. The median β-TP in the study group was 0.8 mg/L (range, 0.05-4.5 mg/L). In the control group, the median β-TP value was 0.16 mg/L (range, 0.01-0.36 mg/L). Thirty-five percent of the values in the study group were below the highest value in the negative control group. The β-TP values of the tympanic cavity samples were significantly higher in the study group than in controls (p = 0.0001). The serum values were 0.55 +/- 0.18 and 0.53 +/- 0.11 mg/L, respectively. It may be feasible to test for PLF fistula using β-TP in samples from the tympanic cavity. Our results, however, suggest a relative low diagnostic sensitivity, given a cutoff that is set to obtain a high specificity when using a simple sample collection method. Furthermore, the test does not permit the distinction between PLF fistula and cerebrospinal fluid fistula. Further studies should focus on minimal dilution at sampling and on minimizing sample volumes.

  14. Cross-Sectional Study of Hepatitis A Virus Infection in the Pantanal Population before Vaccine Implementation in Brazil: Usage of Non-Invasive Specimen Collection

    PubMed Central

    Tourinho, Renata Santos; de Almeida, Adilson José; Villar, Livia Melo; Murat, Paula Guerra; Capelin, Gina Jonasson Mousquer; Motta Castro, Ana Rita Coimbra; de Paula, Vanessa Salete

    2015-01-01

    Population-based prevalence studies are essential tools for screening of hepatitis A and provide important data on susceptible groups. However, surveillance in isolated communities is difficult because of the limited access to these areas and the need for blood sample collection. This study aimed to determine the anti-HAV prevalence using oral fluid samples to provide an alternative tool for epidemiological studies that might be useful for vaccination-related decisions. The study population was composed of 224 volunteers from South Pantanal, aged 3 to 86 years old. This study was performed using oral fluids, previously standardized for anti-HAV antibody detection, which were collected using a ChemBio device. Eluates were tested using modified commercial EIA to detect anti-HAV antibodies. The overall prevalence was 79.1%, corresponding to 178 reactive EIA tests out of 224 samples. The age stratified data revealed a prevalence of 47.8% between 0–10 years, 84% in 11–20 years and 91.9% in subjects older than 21 years. Results indicate that hepatitis A prevalence was higher in adolescents and adults, corroborating the literature reports. Thus, oral fluid samples could replace serum in HAV epidemiological studies in isolated communities as they are efficient at detecting anti-HAV antibodies. PMID:26133128

  15. Urine sampling and collection system optimization and testing

    NASA Technical Reports Server (NTRS)

    Fogal, G. L.; Geating, J. A.; Koesterer, M. G.

    1975-01-01

    A Urine Sampling and Collection System (USCS) engineering model was developed to provide for the automatic collection, volume sensing and sampling of urine from each micturition. The purpose of the engineering model was to demonstrate verification of the system concept. The objective of the optimization and testing program was to update the engineering model, to provide additional performance features and to conduct system testing to determine operational problems. Optimization tasks were defined as modifications to minimize system fluid residual and addition of thermoelectric cooling.

  16. CTP (Cochlin-tomoprotein) detection in the profuse fluid leakage (gusher) from cochleostomy.

    PubMed

    Ikezono, Tetsuo; Sugizaki, Kazuki; Shindo, Susumu; Sekiguchi, Satomi; Pawankar, Ruby; Baba, Shunkichi; Yagi, Toshiaki

    2010-08-01

    By testing 125 samples, we confirmed that Cochlin-tomoprotein (CTP) is present in the perilymph, not in cerebrospinal fluid (CSF). Perilymph and CSF exist in two distinct compartments, even in the case of a malformed inner ear with a bony defect in the lamina cribrosa, as described here. Cochleostomy might have suddenly decreased the perilymph pressure, allowing the influx of CSF into the inner ear resulting in profuse fluid leakage, first perilymph then CSF. The first purpose of this study was to further confirm the specificity of the perilymph-specific protein CTP that we reported recently. Secondly, we assessed the nature of the fluid leakage from the cochleostomy using the CTP detection test. A standardized CTP detection test was performed on 65 perilymph and 60 CSF samples. Samples of profuse fluid leakage collected from cochleostomy during cochlear implantation surgery of one patient with branchio-oto-renal (BOR) syndrome were also tested by the CTP detection test. CTP was detected in 60 of 65 perilymph samples but not in any of the CSF samples. The leaked fluid was shown to contain CTP, i.e. perilymph, at the outset, and then the CTP detection signals gradually disappeared as time elapsed.

  17. Biobanking of different body fluids within the frame of IVF-a standard operating procedure to improve reproductive biology research.

    PubMed

    Schenk, Michael; Huppertz, Berthold; Obermayer-Pietsch, Barbara; Kastelic, Darja; Hörmann-Kröpfl, Martina; Weiss, Gregor

    2017-02-01

    The aim of the present study was to develop a standard operating procedure (SOP) for the collection, transport, and storage of human cumulus cells, follicular fluid, blood serum, seminal plasma, embryo culture supernatant, and embryo culture supernatant control obtained within the IVF process under approved protocols and written informed consent from participating patients. The SOP was developed at the Kinderwunsch Institut Schenk, Dobl, Austria, together with Biobank Graz of the Medical University of Graz, Austria. The SOP provides comprehensive details of laboratory procedures and sampling of the different fluids within the IVF process. Furthermore, information on sample coding, references of involved laboratory techniques (e.g., oocyte retrieval with a Steiner-TAN needle), ethical approvals, and biobanking procedures are presented. The result of the present study is a standard operating procedure. The SOP ensures a professional way for collection and scientific use of IVF samples by the Kinderwunsch Institut Schenk, Dobl, Austria, and Biobank Graz of the Medical University of Graz, Austria. It can be used as a template for other institutions to unify specimen collection procedures in the field of reproductive health research.

  18. Mixing of Magmatic Volatiles With Meteoric Groundwater in the Summit of Kilauea Volcano, Hawaii

    NASA Astrophysics Data System (ADS)

    Hurwitz, S.; Goff, F.; Janik, C. J.; Evans, W. C.; Counce, D. A.; Sorey, M. L.; Ingebritsen, S. E.

    2001-12-01

    Water samples were collected from the only deep well (Keller Well-NSF Well) on the summit of Kilauea volcano, Hawaii. The well was drilled in 1973 to a depth of 1262 m, but sat idle until 1998 when a drilling rig was used to remove mud and renew access to the hydrothermal system at a location very close to summit fumarolic activity. The chemistry and isotopic composition of fluid samples collected in 1998-2001 differ significantly from those of samples collected before 1998 and reported in previous studies. The water from the well is rich in sulfate and has a near-neutral pH. The major element chemistry differs significantly from seawater composition and from that of hydrothermal fluids from Kilauea's east rift zone. The well water has a low chloride concentration relative to typical magmatic-hydrothermal fluids and a high sulfate to bicarbonate ratio (approximately 4:1). Based on the S/Cl mass ratio and on carbon and helium isotopes in the well fluids, summit fumaroles and the parental Kilauea magma, we conclude that the hydrothermal fluids sampled from the well formed by condensation of magmatic volatiles into shallow, mainly meteoric groundwater. The oxygen and deuterium isotopic composition indicate that the meteoric component was recharged on the eastern margin of the caldera. Steam condensation and gas dissolution beneath the crater formed an acidic fluid that dissolved the host basalt at high temperatures. The hydrothermal fluid was then modified by cooling and precipitation of secondary minerals along a flow path away from the crater towards the well. Geochemical modeling based on fluid chemistry and geothermometry suggests that the well fluids equilibrated with an assemblage of secondary minerals at temperatures between 90 and 140oC. The C/S ratios in the well water, the parental magma, and the gas plume emanating from the caldera indicate that most of the sulfur degassed from the magma is scrubbed by groundwaters beneath the summit. However, based on the mean sulfate concentration in the well water and on the estimated mean annual water recharge in the caldera region, we conclude that the sulfate concentration in groundwater beneath Kilauea's summit must be an order of magnitude higher than that found in the well water.

  19. Mixing of magmatic volatiles with groundwater and interaction with basalt on the summit of Kilauea Volcano, Hawaii

    NASA Astrophysics Data System (ADS)

    Hurwitz, Shaul; Goff, Fraser; Janik, Cathy J.; Evans, William C.; Counce, Dale A.; Sorey, Michael L.; Ingebritsen, Steven E.

    2003-01-01

    We interpret new chemical and isotopic data from samples collected between October 1998 and March 2002 from the NSF well (also called the Keller well), the only deep well on the summit of Kilauea Volcano, Hawaii. Sample collection followed cleaning of the well, which renewed access to the hydrothermal system very close to the loci of magmatic and fumarolic activity. The chemical and isotopic compositions of the new samples differ remarkably from data published previously. On the basis of the S/Cl ratio and carbon and helium isotopes we conclude that the thermal fluids formed by condensation of magmatic gas into shallow meteoric groundwater. Gas condensation was followed by a complex pattern of basalt dissolution accompanied by an increase of fluid pH and precipitation of secondary minerals. Geochemical modeling and geothermometry imply that the fluids equilibrated with an assemblage of secondary minerals at temperatures between 90 and 140°C. The significantly different chemical composition of the NSF well fluids from that of springs along the southern coast of the island indicates that mass transport from the summit region toward the lower flanks of the volcano is limited.

  20. Extracting metalworking fluid aerosol samples in cassettes by provisional ASTM and NIOSH methods.

    PubMed

    Harper, Martin

    2002-01-01

    Recent provisional methods for the determination of metalworking fluid aerosol in workplace air involve a solvent extraction procedure to separate the nonvolatile fraction of the fluid from insoluble material such as metal turnings and dirt. The procedure calls for preweighing a filter (W1) and assembling it into a cassette and taking a sample. In the laboratory the filter is removed from the cassette, desiccated to remove any collected water or other volatile substances, and weighed again (W2). The filter is then extracted in an organic solvent blend, allowed to dry, and weighed a final time (W3). The total weight collected by the filter is given by (W2-W1), and the weight of (nonvolatile) metalworking fluid collected is given by (W2-W3). The extraction step can take place within a cassette housing if it is relatively inert to the solvent blend used. The extraction of four metalworking fluids (straight oil, soluble oil, synthetic and semisynthetic) within disposable polypropylene cassettes was investigated using the same protocol used to evaluate the original method. For all fluids the extraction efficiency was greater than 95% with a precision better than 5%. The mean blank contribution to the extraction step was 16 micrograms. Blanks were also evaluated after storage, and after transport and storage. A small additional blank contribution could be removed by desiccation. The limits of detection and quantitation of the extraction step were calculated to be 28 and 94 micrograms, respectively.

  1. Distinguishing infected from noninfected abdominal fluid collections after surgery: an imaging, clinical, and laboratory-based scoring system.

    PubMed

    Gnannt, Ralph; Fischer, Michael A; Baechler, Thomas; Clavien, Pierre-Alain; Karlo, Christoph; Seifert, Burkhardt; Lesurtel, Mickael; Alkadhi, Hatem

    2015-01-01

    Mortality from abdominal abscesses ranges from 30% in treated cases up to 80% to 100% in patients with undrained or nonoperated abscesses. Various computed tomographic (CT) imaging features have been suggested to indicate infection of postoperative abdominal fluid collections; however, features are nonspecific and substantial overlap between infected and noninfected collections exists. The purpose of this study was to develop and validate a scoring system on the basis of CT imaging findings as well as laboratory and clinical parameters for distinguishing infected from noninfected abdominal fluid collections after surgery. The score developmental cohort included 100 consecutive patients (69 men, 31 women; mean age, 58 ± 17 years) who underwent portal-venous phase CT within 24 hours before CT-guided intervention of postoperative abdominal fluid collections. Imaging features included attenuation (Hounsfield unit [HU]), volume, wall enhancement and thickness, fat stranding, as well as entrapped gas of fluid collections. Laboratory and clinical parameters included diabetes, intake of immunosuppressive drugs, body temperature, C-reactive protein, and leukocyte blood cell count. The score was validated in a separate cohort of 30 consecutive patients (17 men, 13 women; mean age, 51 ± 15 years) with postoperative abdominal fluid collections. Microbiologic analysis from fluid samples served as the standard of reference. Diabetes, body temperature, C-reactive protein, attenuation of the fluid collection (in HUs), wall enhancement and thickness of the wall, adjacent fat stranding, as well as entrapped gas within the fluid collection were significantly different between infected and noninfected collections (P < 0.001). Multiple logistic regression analysis revealed diabetes, C-reactive protein, attenuation of the fluid collection (in HUs), as well as entrapped gas as significant independent predictors of infection (P < 0.001) and thus was selected for constructing a scoring system from 0 to 10 (diabetes: 2 points; C-reactive protein, ≥ 100 mg/L: 1 point; attenuation of fluid collection, ≥ 20 HU: 4 points; entrapped gas: 3 points). The model was well calibrated (Hosmer-Lemeshow test, P = 0.36). In the validation cohort, scores of 2 or lower had a 90% (95% confidence interval [CI], 56%-100%) negative predictive value, scores of 3 or higher had an 80% (95% CI, 56%-94%) positive predictive value, and scores of 6 or higher a 100% (95% CI, 74%-100%) positive predictive value for diagnosing infected fluid collections. Receiver operating characteristic analysis revealed an area under the curve of 0.96 (95% CI, 0.88-1.00) for the score. We introduce an accurate scoring system including quantitative radiologic, laboratory, and clinical parameters for distinguishing infected from noninfected fluid collections after abdominal surgery.

  2. Comparison of specimens for detection of porcine reproductive and respiratory syndrome virus infection in boar studs.

    PubMed

    Pepin, B J; Kittawornrat, A; Liu, F; Gauger, P C; Harmon, K; Abate, S; Main, R; Garton, C; Hargrove, J; Rademacher, C; Ramirez, A; Zimmerman, J

    2015-06-01

    Porcine reproductive and respiratory syndrome virus (PRRSV)-contaminated semen from boars is a route of transmission to females, and early detection of PRRSV infection in boars is a key component in sow farm biosecurity. The purpose of this study was to determine the optimum diagnostic specimen(s) for the detection of acute PRRSV infection in boars. Individually housed boars (n = 15) were trained for semen and oral fluid collection and then vaccinated with a commercial PRRSV modified live virus vaccine. Starting on the day of vaccination and for 14 days thereafter, oral fluid specimens were collected daily from all boars. The 15 boars were subdivided into three groups of 5, and serum, blood swabs and 'frothy saliva' were collected at the time of semen collection on a 3-day rotation. Frothy saliva, derived from the submandibular salivary gland, is produced by aroused boars. Semen was centrifuged, and semen supernatant and cell fractions were tested separately. All samples were randomly ordered and then tested by PRRSV real-time quantitative reverse-transcription polymerase chain reaction assay (rRT-PCR) and PRRSV antibody ELISA. In this study, a comparison of serum, blood swab, and oral fluid rRT-PCR results found no statistically significant differences in the onset of detection or proportion of positives, but serum was numerically superior to oral fluids for early detection. Serum and oral fluid provided identical rRT-PCR results at ≥ 5 day post-vaccination. Likewise, the onset of detection of PRRSV antibody in serum, oral fluid and frothy saliva was statistically equivalent, with serum results again showing a numerical advantage. These results showed that the highest assurance of providing PRRSV-negative semen to sow farms should be based on rRT-PCR testing of serum collected at the time of semen collection. This approach can be augmented with oral fluid sampling from a random selection of uncollected boars to provide for statistically valid surveillance of the boar stud. © 2013 Blackwell Verlag GmbH.

  3. A New Method of Obtaining High-Resolution Paleoclimate Records from Speleothem Fluid Inclusions

    NASA Astrophysics Data System (ADS)

    Logan, A. J.; Horton, T. W.

    2010-12-01

    We present a new method for stable hydrogen and oxygen isotope analysis of ancient drip water trapped within cave speleothems. Our method improves on existing fluid inclusion isotopic analytical techniques in that it decreases the sample size by a factor of ten or more, dramatically improving the spatial and temporal precision of fluid inclusion-based paleoclimatology. Published thermal extraction methods require large samples (c. 150 mg) and temperatures high enough (c. 500-900°C) to cause calcite decomposition, which is also associated with isotopic fractionation of the trapped fluids. Extraction by crushing faces similar challenges, where the failure to extract all the trapped fluid can result in isotopic fractionation, and samples in excess of 500 mg are required. Our new method combines the strengths of these published thermal and crushing methods using continuous-flow isotope ratio analytical techniques. Our method combines relatively low-temperature (~250°C) thermal decrepitation with cryogenic trapping across a switching valve sample loop. In brief, ~20 mg carbonate samples are dried (75°C for >1 hour) and heated (250°C for >1 hour) in a quartz sample chamber under a continuously flowing stream of ultra-high purity helium. Heating of the sample chamber is achieved by use of a tube furnace. Fluids released during the heating step are trapped in a coiled stainless steel cold trap (~ -98°C) serving as the sample loop in a 6-way switching valve. Trapped fluids are subsequently injected into a high-temperature conversion elemental analyzer by switching the valve and rapidly thawing the trap. This approach yielded accurate and precise measurements of injected liquid water IAEA reference materials (GISP; SMOW2; SLAP2) for both hydrogen and oxygen isotopic compositions. Blanking tests performed on the extraction line demonstrate extremely low line-blank peak heights (<50mv). Our tests also demonstrate that complete recovery of liquid water is possible and that a minimum quantity of ~100nL water was required. In contrast to liquid water analyses, carbonate inclusion waters gave highly variable results. As plenty of signal was produced from relatively small sample sizes (~20 mg), the observed isotopic variation most likely reflects fractionation during fluid extraction, or natural isotopic variability. Additional tests and modifications to the extraction procedure are in progress, using a recently collected New Zealand stalagmite from a West Coast cave (DOC collection permit WC-27462-GEO). U-Th age data will accompany a paleoclimate record from this stalagmite obtained using standard carbonate analytical techniques, and compared to the results from our new fluid inclusion analyses.

  4. Microbial life in cold, hydrologically active oceanic crustal fluids

    NASA Astrophysics Data System (ADS)

    Meyer, J. L.; Jaekel, U.; Girguis, P. R.; Glazer, B. T.; Huber, J. A.

    2012-12-01

    It is estimated that at least half of Earth's microbial biomass is found in the deep subsurface, yet very little is known about the diversity and functional roles of these microbial communities due to the limited accessibility of subseafloor samples. Ocean crustal fluids, which may have a profound impact on global nutrient cycles given the large volumes of water moving through the crustal aquifer, are particularly difficult to sample. Access to uncontaminated ocean crustal fluids is possible with CORK (Circulation Obviation Retrofit Kit) observatories, installed through the Integrated Ocean Drilling Program (IODP). Here we present the first microbiological characterization of the formation fluids from cold, oxygenated igneous crust at North Pond on the western flank of the Mid Atlantic Ridge. Fluids were collected from two CORKs installed at IODP boreholes 1382A and 1383C and include fluids from three different depth horizons within oceanic crust. Collection of borehole fluids was monitored in situ using an oxygen optode and solid-state voltammetric electrodes. In addition, discrete samples were analyzed on deck using a comparable lab-based system as well as a membrane-inlet mass spectrometer to quantify all dissolved volatiles up to 200 daltons. The instruments were operated in parallel and both in situ and shipboard geochemical measurements point to a highly oxidized fluid, revealing an apparent slight depletion of oxygen in subsurface fluids (~215μM) relative to bottom seawater (~245μM). We were unable to detect reduced hydrocarbons, e.g. methane. Cell counts indicated the presence of roughly 2 x 10^4 cells per ml in all fluid samples, and DNA was extracted and amplified for the identification of both bacterial and archaeal community members. The utilization of ammonia, nitrate, dissolved inorganic carbon, and acetate was measured using stable isotopes, and oxygen consumption was monitored to provide an estimate of the rate of respiration per cell per day. These results provide the first dataset describing the diversity of microbes present in cold, oxygenated ocean crustal fluids and the biogeochemical processes they mediate in the subseafloor.

  5. Pilot test of new roadside survey methodology for impaired driving

    DOT National Transportation Integrated Search

    2007-01-01

    This study developed and tested procedures to enhance roadside survey procedures to include collecting and analyzing oral fluid and blood samples from the nighttime weekend driving population. Roadside surveys involve collecting information from a ra...

  6. 40 CFR Appendix 1 to Subpart A of... - Static Sheen Test

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... drilling fluids, drill cuttings, produced sand, and well treatment, completion and workover fluids. “Free... drill cuttings or produced sand are introduced into ambient seawater in a container having an air-to... specified. 6. Quality Control Procedures None currently specified. 7. Sample Collection and Handling 7...

  7. Major- and minor-metal composition of three distinct solid material fractions associated with Juan de Fuca hydrothermal fluids (northeast Pacific), and calculation of dilution fluid samples

    USGS Publications Warehouse

    Hinkley, T.K.; Seeley, J.L.; Tatsumoto, M.

    1988-01-01

    Three distinct types of solid material are associated with each sample of the hydrothermal fluid that was collected from the vents of the Southern Juan de Fuca Ridge. The solid materials appear to be representative of deposits on ocean floors near mid-ocean ridges, and interpretation of the chemistry of the hydrothermal solutions requires understanding of them. Sr isotopic evidence indicates that at least two and probably all three of these solid materials were removed from the solution with which they are associated, by precipitation or adsorption. This occurred after the "pure" hydrothermal fluid was diluted and thoroughly mixed with ambient seawater. The three types of solid materials, are, respectively, a coarse Zn- and Fe-rich material with small amounts of Na and Ca; a finer material also rich in Zn and Fe, but with alkali and alkaline-earth metals; and a scum composed of Ba or Zn, with either considerable Fe or Si, and Sr. Mineral identification is uncertain because of uncertain anion composition. Only in the cases of Ba and Zn were metal masses greater in solid materials than in the associated fluids. For all other metals measured, masses in fluids dwarf those in solids. The fluids themselves contain greater concentrations of all metals measured, except Mg, than seawater. We discuss in detail the relative merits of two methods of determining the mixing proportions of "pure" hydrothermal solution and seawater in the fluids, one based on Sr isotopes, and another previously used method based on Mg concentrations. Comparison of solute concentrations in the several samples shows that degree of dilution of "pure" hydrothermal solutions by seawater, and amounts of original solutes that were removed from it as solid materials, are not related. There is no clear evidence that appreciable amounts of solid materials were not conserved (lost) either during or prior to sample collection. ?? 1988.

  8. Green tea catechins and their metabolites in human skin before and after exposure to ultraviolet radiation.

    PubMed

    Clarke, Kayleigh A; Dew, Tristan P; Watson, Rachel E B; Farrar, Mark D; Osman, Joanne E; Nicolaou, Anna; Rhodes, Lesley E; Williamson, Gary

    2016-01-01

    Dietary flavonoids may protect against sunburn inflammation in skin. Preliminary reports using less complete analysis suggest that certain catechins and their metabolites are found in skin biopsies and blister fluid after consumption of green tea; however, it is not known if they are affected by solar-simulated ultraviolet radiation (UVR) or whether conjugated forms, with consequently altered bioactivity, are present. The present study tested the hypothesis that UVR affects the catechin levels in the skin of healthy volunteers after consumption of green tea and how catechins in the plasma are related to their presence in skin tissue samples. In an open oral intervention study, 11 subjects consumed green tea and vitamin C supplements daily for 3months. Presupplementation and postsupplementation plasma samples, suction blister fluid and skin biopsies were collected; the latter two samples were collected both before and after UVR. A sensitive high-performance liquid chromatography/mass spectrometric assay was used to measure the intact catechin metabolites, conjugates and free forms. Seven green tea catechins and their corresponding metabolites were identified postsupplementation in skin biopsies, 20 in blister fluid and 26 in plasma, with 15 green tea catechin metabolites present in both blister fluid and plasma. The valerolactone, O-methyl-M4-O-sulfate, a gut microbiota metabolite of catechins, was significantly increased 1.6-fold by UVR in blister fluid samples. In conclusion, there were some common catechin metabolites in the plasma and blister fluid, and the concentration was always higher in plasma. The results suggest that green tea catechins and metabolites are bioavailable in skin and provide a novel link between catechin metabolites derived from the skin and gut microbiota. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.

  9. Green tea catechins and their metabolites in human skin before and after exposure to ultraviolet radiation☆☆☆★

    PubMed Central

    Clarke, Kayleigh A.; Dew, Tristan P.; Watson, Rachel E.B.; Farrar, Mark D.; Osman, Joanne E.; Nicolaou, Anna; Rhodes, Lesley E.; Williamson, Gary

    2016-01-01

    Dietary flavonoids may protect against sunburn inflammation in skin. Preliminary reports using less complete analysis suggest that certain catechins and their metabolites are found in skin biopsies and blister fluid after consumption of green tea; however, it is not known if they are affected by solar-simulated ultraviolet radiation (UVR) or whether conjugated forms, with consequently altered bioactivity, are present. The present study tested the hypothesis that UVR affects the catechin levels in the skin of healthy volunteers after consumption of green tea and how catechins in the plasma are related to their presence in skin tissue samples. In an open oral intervention study, 11 subjects consumed green tea and vitamin C supplements daily for 3 months. Presupplementation and postsupplementation plasma samples, suction blister fluid and skin biopsies were collected; the latter two samples were collected both before and after UVR. A sensitive high-performance liquid chromatography/mass spectrometric assay was used to measure the intact catechin metabolites, conjugates and free forms. Seven green tea catechins and their corresponding metabolites were identified postsupplementation in skin biopsies, 20 in blister fluid and 26 in plasma, with 15 green tea catechin metabolites present in both blister fluid and plasma. The valerolactone, O-methyl-M4-O-sulfate, a gut microbiota metabolite of catechins, was significantly increased 1.6-fold by UVR in blister fluid samples. In conclusion, there were some common catechin metabolites in the plasma and blister fluid, and the concentration was always higher in plasma. The results suggest that green tea catechins and metabolites are bioavailable in skin and provide a novel link between catechin metabolites derived from the skin and gut microbiota. PMID:26454512

  10. Perilymph composition in scala tympani of the cochlea: influence of cerebrospinal fluid.

    PubMed

    Hara, A; Salt, A N; Thalmann, R

    1989-11-01

    A commonly used technique to obtain cochlear perilymph for analysis has been the aspiration of samples through the round window membrane. The present study has investigated the influence of the volume withdrawn on sample composition in the guinea pig. Samples of less than 200 nl in volume taken through the round window showed relatively high glycine content, comparable to the level found in samples taken from scala vestibuli. If larger volumes are withdrawn, lower glycine levels are observed. This is consistent with cerebrospinal fluid (having a low glycine content) being drawn into scala tympani through the cochlear aqueduct and contaminating the sample. The existence of a concentration difference for glycine between scala tympani perilymph and cerebrospinal fluid suggests the physiologic communication across the cochlear aqueduct is relatively small in this species. The observation of considerable exchange between cerebrospinal fluid and perilymph, as reported in some studies, is more likely to be an artifact of the experimental procedures, rather than of physiologic significance. Alternative sampling procedures have been evaluated which allow larger volumes of uncontaminated scala tympani perilymph to be collected.

  11. Current Research at the Endeavour Ridge 2000 Integrated Studies Site

    NASA Astrophysics Data System (ADS)

    Butterfield, D. A.; Kelley, D. S.; Ridge 2000 Community, R.

    2004-12-01

    Integrated geophysical, geological, chemical, and biological studies are being conducted on the Endeavour segment with primary support from NSF, the W.M. Keck Foundation, and NSERC (Canada). The research includes a seismic network, physical and chemical sensors, high-precision mapping and time-series sampling. Several research expeditions have taken place at the Endeavour ISS in the past year. In June 2003, an NSF-sponsored cruise with R.V. al T.G.Thompson/ROV al Jason2 installed microbial incubators in drill-holes in the sides of active sulfide chimneys and sampled rocks, fluids, and microbes in the Mothra and Main Endeavour Field (MEF). In July 2003, with al Thompson/Jason2, an NSF-LEXEN project at Baby Bare on Endeavour east flank conducted sampling through seafloor-penetrating probes, plus time-series sampling of fluids, microbes, and rocks at the MEF. In September 2003, with al Thompson/ROV al ROPOS, the Keck Proto-Neptune project installed a seismic network consisting of 1 broadband and 7 short-period seismometers, installation of chemical/physical sensors and time-series samplers for chemistry and microbiology in the MEF and Clam Bed sites, collection of rocks, fluids, animals, and microbes. In May/June 2004, an NSF-sponsored al Atlantis/Alvin cruise recovered sulfide incubators installed in 2003, redeployed a sulfide incubator, mapped MEF and Mothra vent fields with high-resolution Imagenix sonar, sampled fluids from MEF, Mothra, and Clam Bed, recovered year-long time-series fluid and microbial samplers from MEF and Clam Bed, recovered and installed hot vent temperature-resistivity monitors, cleaned up the MEF and deployed new markers at major sulfide structures. In August 2004, there were two MBARI/Keck-sponsored cruises with R.V. al Western Flyer/ROV al Tiburon. The first cruise completed the seismic network with addition of two more broadband seismometers and serviced all 7 short-period seismometers. al Tiburon then performed microbial and chemical investigations at MEF, Mothra, Sasquatch, and Middle Valley, collecting fluid, particle, and animal samples for culture and phylogenetic analysis. al Tiburon continued in late August/September with detailed petrological sampling. A Keck-sponsored al Thompson/ROPOS cruise in September continued work on chemical/physical sensor deployments and time-series chemical and microbial sampling. A graduate student workshop at Friday Harbor beginning October 2004 will analyze the first year of data from the seismic network and begin to correlate seismic activity with hydrothermal activity. The Endeavour ISS is still in a phase of data collection and sensor development, but moving toward data integration.

  12. Influenza A Virus Surveillance Based on Pre-Weaning Piglet Oral Fluid Samples.

    PubMed

    Panyasing, Y; Goodell, C; Kittawornrat, A; Wang, C; Levis, I; Desfresne, L; Rauh, R; Gauger, P C; Zhang, J; Lin, X; Azeem, S; Ghorbani-Nezami, S; Yoon, K-J; Zimmerman, J

    2016-10-01

    Influenza A virus (IAV) surveillance using pre-weaning oral fluid samples from litters of piglets was evaluated in four ˜12 500 sow and IAV-vaccinated, breeding herds. Oral fluid samples were collected from 600 litters and serum samples from their dams at weaning. Litter oral fluid samples were tested for IAV by virus isolation, quantitative reverse transcription-polymerase chain reaction (qRT-PCR), RT-PCR subtyping and sequencing. Commercial nucleoprotein (NP) enzyme-linked immunosorbent assay (ELISA) kits and NP isotype-specific assays (IgM, IgA and IgG) were used to characterize NP antibody in litter oral fluid and sow serum. All litter oral fluid specimens (n = 600) were negative by virus isolation. Twenty-five oral fluid samples (25/600 = 4.2%) were qRT-PCR positive based on screening (Laboratory 1) and confirmatory testing (Laboratory 2). No hemagglutinin (HA) and neuraminidase (NA) gene sequences were obtained, but matrix (M) gene sequences were obtained for all qRT-PCR-positive samples submitted for sequencing (n = 18). Genetic analysis revealed that all M genes sequences were identical (GenBank accession no. KF487544) and belonged to the triple reassortant influenza A virus M gene (TRIG M) previously identified in swine. The proportion of IgM- and IgA-positive samples was significantly higher in sow serum and litter oral fluid samples, respectively (P < 0.01). Consistent with the extensive use of IAV vaccine, no difference was detected in the proportion of IgG- and blocking ELISA-positive sow serum and litter oral fluids. This study supported the use of oral fluid sampling as a means of conducting IAV surveillance in pig populations and demonstrated the inapparent circulation of IAV in piglets. Future work on IAV oral fluid diagnostics should focus on improved procedures for virus isolation, subtyping and sequencing of HA and NA genes. The role of antibody in IAV surveillance remains to be elucidated, but longitudinal assessment of specific antibody has the potential to provide information regarding patterns of infection, vaccination status and herd immunity. © 2014 Blackwell Verlag GmbH.

  13. Effect of bolus fluid intake on energy expenditure values as determined by the doubly labeled water method

    NASA Technical Reports Server (NTRS)

    Drews, D.; Stein, T. P.

    1992-01-01

    The doubly labeled water (DLW, 2H(2)18O) method is a highly accurate method for measuring energy expenditure (EE). A possible source of error is bolus fluid intake before body water sampling. If there is bolus fluid intake immediately before body water sampling, the saliva may reflect the ingested water disproportionately, because the ingested water may not have had time to mix fully with the body water pool. To ascertain the magnitude of this problem, EE was measured over a 5-day period by the DLW method. Six subjects were dosed with 2H2(18)O. After the reference salivas for the two-point determination were obtained, subjects drank water (700-1,000 ml), and serial saliva samples were collected for the next 3 h. Expressing the postbolus saliva enrichments as a percentage of the prebolus value, we found 1) a minimum in the saliva isotopic enrichments were reached at approximately 30 min with the minimum for 2H (95.48 +/- 0.43%) being significantly lower than the minimum for 18O (97.55 +/- 0.44, P less than 0.05) and 2) EE values calculated using the postbolus isotopic enrichments are appreciably higher (19.9 +/- 7.5%) than the prebolus reference values. In conclusion, it is not advisable to collect saliva samples for DLW measurements within approximately 1 h of bolus fluid intake.

  14. Ceramic debris in hip prosthesis: correlation between synovial fluid and joint capsule.

    PubMed

    De Pasquale, Dalila; Stea, Susanna; Beraudi, Alina; Montesi, Monica; Squarzoni, Stefano; Toni, Aldo

    2013-05-01

    Detection of ceramic particles in synovial fluids allows early diagnosis of ceramic damage, but there is no evidence of a relationship between ceramic debris in the articular space and in the joint capsule. The aim of the present study is to verify if the particles isolated in the synovial fluid are comparable with those stored in the capsular tissue. Twenty-one patients were enrolled. Both synovial fluid and capsular samples were collected during revision surgery and ceramic particles were isolated and analyzed by scanning electron microscopy and energy-dispersive X-ray microanalysis. It resulted a significant correlation between the samples couples (18 out of 21). This study confirms that the synovial fluid analysis can give a clear definition of the presence of particles in the joint capsule. Copyright © 2013 Elsevier Inc. All rights reserved.

  15. Mechanisms of sampling interstitial fluid from skin using a microneedle patch.

    PubMed

    Samant, Pradnya P; Prausnitz, Mark R

    2018-05-01

    Although interstitial fluid (ISF) contains biomarkers of physiological significance and medical interest, sampling of ISF for clinical applications has made limited impact due to a lack of simple, clinically useful techniques that collect more than nanoliter volumes of ISF. This study describes experimental and theoretical analysis of ISF transport from skin using microneedle (MN) patches and demonstrates collection of >1 µL of ISF within 20 min in pig cadaver skin and living human subjects using an optimized system. MN patches containing arrays of submillimeter solid, porous, or hollow needles were used to penetrate superficial skin layers and access ISF through micropores (µpores) formed upon insertion. Experimental studies in pig skin found that ISF collection depended on transport mechanism according to the rank order diffusion < capillary action < osmosis < pressure-driven convection, under the conditions studied. These findings were in agreement with independent theoretical modeling that considered transport within skin, across the interface between skin and µpores, and within µpores to the skin surface. This analysis indicated that the rate-limiting step for ISF sampling is transport through the dermis. Based on these studies and other considerations like safety and convenience for future clinical use, we designed an MN patch prototype to sample ISF using suction as the driving force. Using this approach, we collected ISF from human volunteers and identified the presence of biomarkers in the collected ISF. In this way, sampling ISF from skin using an MN patch could enable collection of ISF for use in research and medicine.

  16. Sampling guidelines for oral fluid-based surveys of group-housed animals.

    PubMed

    Rotolo, Marisa L; Sun, Yaxuan; Wang, Chong; Giménez-Lirola, Luis; Baum, David H; Gauger, Phillip C; Harmon, Karen M; Hoogland, Marlin; Main, Rodger; Zimmerman, Jeffrey J

    2017-09-01

    Formulas and software for calculating sample size for surveys based on individual animal samples are readily available. However, sample size formulas are not available for oral fluids and other aggregate samples that are increasingly used in production settings. Therefore, the objective of this study was to develop sampling guidelines for oral fluid-based porcine reproductive and respiratory syndrome virus (PRRSV) surveys in commercial swine farms. Oral fluid samples were collected in 9 weekly samplings from all pens in 3 barns on one production site beginning shortly after placement of weaned pigs. Samples (n=972) were tested by real-time reverse-transcription PCR (RT-rtPCR) and the binary results analyzed using a piecewise exponential survival model for interval-censored, time-to-event data with misclassification. Thereafter, simulation studies were used to study the barn-level probability of PRRSV detection as a function of sample size, sample allocation (simple random sampling vs fixed spatial sampling), assay diagnostic sensitivity and specificity, and pen-level prevalence. These studies provided estimates of the probability of detection by sample size and within-barn prevalence. Detection using fixed spatial sampling was as good as, or better than, simple random sampling. Sampling multiple barns on a site increased the probability of detection with the number of barns sampled. These results are relevant to PRRSV control or elimination projects at the herd, regional, or national levels, but the results are also broadly applicable to contagious pathogens of swine for which oral fluid tests of equivalent performance are available. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  17. Investigation of extractable organic compounds in deep-sea hydrothermal vent fluids along the Mid-Atlantic Ridge

    NASA Astrophysics Data System (ADS)

    McCollom, Thomas M.; Seewald, Jeffrey S.; German, Christopher R.

    2015-05-01

    The possibility that deep-sea hydrothermal vents may contain organic compounds produced by abiotic synthesis or by microbial communities living deep beneath the surface has led to numerous studies of the organic composition of vent fluids. Most of these studies have focused on methane and other light hydrocarbons, while the possible occurrence of more complex organic compounds in the fluids has remained largely unstudied. To address this issue, the presence of higher molecular weight organic compounds in deep-sea hydrothermal fluids was assessed at three sites along the Mid-Atlantic Ridge that span a range of temperatures (51 to >360 °C), fluid compositions, and host-rock lithologies (mafic to ultramafic). Samples were obtained at several sites within the Lucky Strike, Rainbow, and Lost City hydrothermal fields. Three methods were employed to extract organic compounds for analysis, including liquid:liquid extraction, cold trapping on the walls of a coil of titanium tubing, and pumping fluids through cartridges filled with solid phase extraction (SPE) sorbents. The only samples to consistently yield high amounts of extractable organic compounds were the warm (51-91 °C), highly alkaline fluids from Lost City, which contained elevated concentrations of C8, C10, and C12n-alkanoic acids and, in some cases, trithiolane, hexadecanol, squalene, and cholesterol. Collectively, the C8-C12 acids can account for about 15% of the total dissolved organic carbon in the Lost City fluids. The even-carbon-number predominance of the alkanoic acids indicates a biological origin, but it is unclear whether these compounds are derived from microbial activity occurring within the hydrothermal chimney proximal to the site of fluid discharge or are transported from deeper within the system. Hydrothermal fluids from the Lucky Strike and Rainbow fields were characterized by an overall scarcity of extractable dissolved organic compounds. Trace amounts of aromatic hydrocarbons including phenanthrenes and benzothiophene were the only compounds that could be identified as indigenous components of these fluids. Although hydrocarbons and fatty acids were observed in some samples, those compounds were likely derived from particulate matter or biomass entrained during fluid collection. In addition, extracts of some fluid samples from the Rainbow field were found to contain an unresolved complex mixture (UCM) of organic compounds. This UCM shared some characteristics with organic matter extracted from bottom seawater, suggesting that the organic matter observed in these samples might represent seawater-derived compounds that had persisted, albeit with partial alteration, during circulation through the hydrothermal system. While there is considerable evidence that Rainbow and Lost City vent fluids contain methane and other light hydrocarbons produced through abiotic reduction of inorganic carbon, we found no evidence for more complex organic compounds with an abiotic origin in the same fluids.

  18. Geochemical and isotopic features of geothermal fluids around the Sea of Marmara, NW Turkey

    NASA Astrophysics Data System (ADS)

    Italiano, Francesco; Woith, Heiko; Seyis, Cemil; Pizzino, Luca; Sciarra, Alessandra

    2016-04-01

    Earthquake processes provoke modifications of the crust affecting the fluid regime with changes in water level in wells, in temperature and/or chemical composition of groundwaters, in the flow-rate of gas discharges and in their chemical and isotopic composition. In the frame of MARsite (MARsite has received funding from the European Union's Seventh Programme for research, technological development and demonstration under grant agreement No 308417) the relationship between fluids and seismogenesis has been approached collecting geochemical data of local significance and evaluating them in geochemical interpretative models of fluids circulation and interactions as well as defining their behaviour over a seismic-prone area. During three fluid sampling campaigns in 2013, 2014, and 2015 a suite of 120 gas samples were collected from 72 thermal and mineral water springs/wells in the wider Marmara region along the Northern and Southern branches of the North Anatolian Fault Zone (NAFZ). Bubbling gases were collected if available, in all other cases the gas phase was extracted from water samples collected on that purpose. Gas samples were analyzed for the main chemical composition as well as their isotopic composition (He and C). The results highlight that the vented gases are a binary mixture of two end-members having nitrogen and carbon dioxide as main components. The geochemical features of the gas phase are the result of several processes that have modified their pristine composition. Atmospheric and deep-originated volatiles mix at variable extents and interact with cold and hot groundwaters. CO2 is normally the main gas species. But it's concentration may decrease due to gas-water interactions (GWI) increasing the relative concentration of N2 and other less soluble gases. A high CO2 content indicates minor interactions. Thus, the easier and faster the pathways are from the deep layers toward the Earth's surface, the lower are the interactions. The volatiles keep their pristine composition. Faults represent a preferential way for rising volatiles due to local high permeability. 3He/4He ratios ranging from 0.1 to 4.8Ra (Ra = 3He/4He atmospheric ratio) indicate the presence of mantle contribution. The highest ratio was found at the eastern end of the Ganos fault. Mantle degassing is not obvious in non-volcanic areas, however the measured helium isotopic ratios indicate mantle degassing likely through lithospheric faults. All the information we got indicate that the fluids circulating over this area are the result of fluid mixing at variable extents of three end-members: mantle, crust and atmosphere.

  19. Application of programmable bio-nano-chip system for the quantitative detection of drugs of abuse in oral fluids.

    PubMed

    Christodoulides, Nicolaos; De La Garza, Richard; Simmons, Glennon W; McRae, Michael P; Wong, Jorge; Newton, Thomas F; Smith, Regina; Mahoney, James J; Hohenstein, Justin; Gomez, Sobeyda; Floriano, Pierre N; Talavera, Humberto; Sloan, Daniel J; Moody, David E; Andrenyak, David M; Kosten, Thomas R; Haque, Ahmed; McDevitt, John T

    2015-08-01

    There is currently a gap in on-site drug of abuse monitoring. Current detection methods involve invasive sampling of blood and urine specimens, or collection of oral fluid, followed by qualitative screening tests using immunochromatographic cartridges. While remote laboratories then may provide confirmation and quantitative assessment of a presumptive positive, this instrumentation is expensive and decoupled from the initial sampling making the current drug-screening program inefficient and costly. The authors applied a noninvasive oral fluid sampling approach integrated with the in-development chip-based Programmable bio-nano-chip (p-BNC) platform for the detection of drugs of abuse. The p-BNC assay methodology was applied for the detection of tetrahydrocannabinol, morphine, amphetamine, methamphetamine, cocaine, methadone and benzodiazepines, initially using spiked buffered samples and, ultimately, using oral fluid specimen collected from consented volunteers. Rapid (∼10min), sensitive detection (∼ng/mL) and quantitation of 12 drugs of abuse was demonstrated on the p-BNC platform. Furthermore, the system provided visibility to time-course of select drug and metabolite profiles in oral fluids; for the drug cocaine, three regions of slope were observed that, when combined with concentration measurements from this and prior impairment studies, information about cocaine-induced impairment may be revealed. This chip-based p-BNC detection modality has significant potential to be used in the future by law enforcement officers for roadside drug testing and to serve a variety of other settings, including outpatient and inpatient drug rehabilitation centers, emergency rooms, prisons, schools, and in the workplace. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  20. The limitations of Gram-stain microscopy of synovial fluid in concomitant septic and crystal arthritis.

    PubMed

    Stirling, Paul; Tahir, Mohammed; Atkinson, Henry Dushan

    2017-03-29

    Rapid diagnosis of septic arthritis from Gram-stain microscopy is limited by an inherent false-negative rate of 25-78%. The presence of concomitant crystal arthritis in 5% of cases represents a particular diagnostic challenge. This study aims to investigate the effects that a concomitant crystal arthropathy have on the ability of Gram-stain microscopy of synovial fluid to diagnose a septic arthritis. This is a 12-year retrospective cohort study. Inclusion criteria were a positive synovial fluid culture result with a positive clinical diagnosis of septic arthritis. Results were correlated with presence or absence of urate and calcium pyrophosphate crystals, and Gram-stain result. During this time our collection and analysis methods remained unchanged. All samples were collected in Lithium Heparin containers. Chi-squared test with a p value < 0.05 was considered significant. 602 synovial fluid samples were included. 162 cases of concomitant crystal arthritis were identified (27%). Of these, 16 (10%) had an initial negative Gram-stain. Of the 440 samples with no crystals detected, 18 (4%) had an initial negative Gram-stain microscopy result (p < 0.05). The incidence of concurrent septic and crystal arthritis may be higher than previously thought. Synovial fluid samples in concomitant septic and crystal arthritis are significantly less likely to have a positive Gram-stain at microscopy than in cases of an isolated septic arthritis. We would advise the clinician to maintain a high index of suspicion for septic arthritis in these patients. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  1. Application of Programmable Bio-Nano-Chip System for the Quantitative Detection of Drugs of Abuse in Oral Fluids*

    PubMed Central

    Christodoulides, Nicolaos; De La Garza, Richard; Simmons, Glennon W.; McRae, Michael P.; Wong, Jorge; Newton, Thomas F.; Smith, Regina; Mahoney, James J.; Hohenstein, Justin; Gomez, Sobeyda; Floriano, Pierre N.; Talavera, Humberto; Sloan, Daniel J.; Moody, David E.; Andrenyak, David M.; Kosten, Thomas R.; Haque, Ahmed; McDevitt, John T.

    2015-01-01

    Objective There is currently a gap in on-site drug of abuse monitoring. Current detection methods involve invasive sampling of blood and urine specimens, or collection of oral fluid, followed by qualitative screening tests using immunochromatographic cartridges. While remote laboratories then may provide confirmation and quantitative assessment of a presumptive positive, this instrumentation is expensive and decoupled from the initial sampling making the current drug-screening program inefficient and costly. The authors applied a noninvasive oral fluid sampling approach integrated with the in-development chip-based Programmable Bio-Nano-Chip (p-BNC) platform for the detection of drugs of abuse. Method The p-BNC assay methodology was applied for the detection of tetrahydrocannabinol, morphine, amphetamine, methamphetamine, cocaine, methadone and benzodiazepines, initially using spiked buffered samples and, ultimately, using oral fluid specimen collected from consented volunteers. Results Rapid (~10 minutes), sensitive detection (~ng/ml) and quantitation of 12 drugs of abuse was demonstrated on the p-BNC platform. Furthermore, the system provided visibility to time-course of select drug and metabolite profiles in oral fluids; for the drug cocaine, three regions of slope were observed that, when combined with concentration measurements from this and prior impairment studies, information about cocaine-induced impairment may be revealed. Conclusions This chip-based p-BNC detection modality has significant potential to be used in the future by law enforcement officers for roadside drug testing and to serve a variety of other settings, including outpatient and inpatient drug rehabilitation centers, emergency rooms, prisons, schools, and in the workplace. PMID:26048639

  2. Boiling-induced formation of colloidal gold in black smoker hydrothermal fluids

    USGS Publications Warehouse

    Gartman, Amy; Hannington, Mark; Jamieson, John W.; Peterkin, Ben; Garbe-Schönberg, Dieter; Findlay, Alyssa J; Fuchs, Sebastian; Kwasnitschka, Tom

    2017-01-01

    Gold colloids occur in black smoker fluids from the Niua South hydrothermal vent field, Lau Basin (South Pacific Ocean), confirming the long-standing hypothesis that gold may undergo colloidal transport in hydrothermal fluids. Six black smoker vents, varying in temperature from 250 °C to 325 °C, were sampled; the 325 °C vent was boiling at the time of sampling and the 250 °C fluids were diffusely venting. Native gold particles ranging from <50 nm to 2 µm were identified in 4 of the fluid samples and were also observed to precipitate on the sampler during collection from the boiling vent. Total gold concentrations (dissolved and particulate) in the fluid samples range from 1.6 to 5.4 nM in the high-temperature, focused flow vents. Although the gold concentrations in the focused flow fluids are relatively high, they are lower than potential solubilities prior to boiling and indicate that precipitation was boiling induced, with sulfide lost upon boiling to exsolution and metal sulfide formation. Gold concentrations reach 26.7 nM in the 250 °C diffuse flow sample, and abundant native gold particles were also found in the fluids and associated sulfide chimney and are interpreted to be a product of colloid accumulation and growth following initial precipitation upon boiling. These results indicate that colloid-driven precipitation as a result of boiling, the persistence of colloids after boiling, and the accumulation of colloids in diffuse flow fluids are important mechanisms for the enrichment of gold in seafloor hydrothermal systems.

  3. Biomolecular signatures of diabetic wound healing by structural mass spectrometry

    PubMed Central

    Hines, Kelly M.; Ashfaq, Samir; Davidson, Jeffrey M.; Opalenik, Susan R.; Wikswo, John P.; McLean, John A.

    2013-01-01

    Wound fluid is a complex biological sample containing byproducts associated with the wound repair process. Contemporary techniques, such as immunoblotting and enzyme immunoassays, require extensive sample manipulation and do not permit the simultaneous analysis of multiple classes of biomolecular species. Structural mass spectrometry, implemented as ion mobility-mass spectrometry (IM-MS), comprises two sequential, gas-phase dispersion techniques well suited for the study of complex biological samples due to its ability to separate and simultaneously analyze multiple classes of biomolecules. As a model of diabetic wound healing, polyvinyl alcohol (PVA) sponges were inserted subcutaneously into non-diabetic (control) and streptozotocin-induced diabetic rats to elicit a granulation tissue response and to collect acute wound fluid. Sponges were harvested at days 2 or 5 to capture different stages of the early wound healing process. Utilizing IM-MS, statistical analysis, and targeted ultra-performance liquid chromatography (UPLC) analysis, biomolecular signatures of diabetic wound healing have been identified. The protein S100-A8 was highly enriched in the wound fluids collected from day 2 diabetic rats. Lysophosphatidylcholine (20:4) and cholic acid also contributed significantly to the differences between diabetic and control groups. This report provides a generalized workflow for wound fluid analysis demonstrated with a diabetic rat model. PMID:23452326

  4. Liquid-Based Medium Used to Prepare Cytological Breast Nipple Fluid Improves the Quality of Cellular Samples Automatic Collection

    PubMed Central

    Zonta, Marco Antonio; Velame, Fernanda; Gema, Samara; Filassi, Jose Roberto; Longatto-Filho, Adhemar

    2014-01-01

    Background Breast cancer is the second cause of death in women worldwide. The spontaneous breast nipple discharge may contain cells that can be analyzed for malignancy. Halo® Mamo Cyto Test (HMCT) was recently developed as an automated system indicated to aspirate cells from the breast ducts. The objective of this study was to standardize the methodology of sampling and sample preparation of nipple discharge obtained by the automated method Halo breast test and perform cytological evaluation in samples preserved in liquid medium (SurePath™). Methods We analyzed 564 nipple fluid samples, from women between 20 and 85 years old, without history of breast disease and neoplasia, no pregnancy, and without gynecologic medical history, collected by HMCT method and preserved in two different vials with solutions for transport. Results From 306 nipple fluid samples from method 1, 199 (65%) were classified as unsatisfactory (class 0), 104 (34%) samples were classified as benign findings (class II), and three (1%) were classified as undetermined to neoplastic cells (class III). From 258 samples analyzed in method 2, 127 (49%) were classified as class 0, 124 (48%) were classified as class II, and seven (2%) were classified as class III. Conclusion Our study suggests an improvement in the quality and quantity of cellular samples when the association of the two methodologies is performed, Halo breast test and the method in liquid medium. PMID:29147397

  5. Hydrogeology, chemical and microbial activity measurement through deep permafrost

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stotler, R.L.; Frape, S.K.; Freifeld, B.M.

    2010-04-01

    Little is known about hydrogeochemical conditions beneath thick permafrost, particularly in fractured crystalline rock, due to difficulty in accessing this environment. The purpose of this investigation was to develop methods to obtain physical, chemical, and microbial information about the subpermafrost environment from a surface-drilled borehole. Using a U-tube, gas and water samples were collected, along with temperature, pressure, and hydraulic conductivity measurements, 420 m below ground surface, within a 535 m long, angled borehole at High Lake, Nunavut, Canada, in an area with 460-m-thick permafrost. Piezometric head was well above the base of the permafrost, near land surface. Initial watermore » samples were contaminated with drill fluid, with later samples <40% drill fluid. The salinity of the non-drill fluid component was <20,000 mg/L, had a Ca/Na ratio above 1, with {delta}{sup 18}O values {approx}5{per_thousand} lower than the local surface water. The fluid isotopic composition was affected by the permafrost-formation process. Nonbacteriogenic CH{sub 4} was present and the sample location was within methane hydrate stability field. Sampling lines froze before uncontaminated samples from the subpermafrost environment could be obtained, yet the available time to obtain water samples was extended compared to previous studies. Temperature measurements collected from a distributed temperature sensor indicated that this issue can be overcome easily in the future. The lack of methanogenic CH{sub 4} is consistent with the high sulfate concentrations observed in cores. The combined surface-drilled borehole/U-tube approach can provide a large amount of physical, chemical, and microbial data from the subpermafrost environment with few, controllable, sources of contamination.« less

  6. Hydrogeology, Chemical and Microbial Activity Measurement Through Deep Permafrost

    USGS Publications Warehouse

    Stotler, R.L.; Frape, S.K.; Freifeld, B.M.; Holden, B.; Onstott, T.C.; Ruskeeniemi, T.; Chan, E.

    2011-01-01

    Little is known about hydrogeochemical conditions beneath thick permafrost, particularly in fractured crystalline rock, due to difficulty in accessing this environment. The purpose of this investigation was to develop methods to obtain physical, chemical, and microbial information about the subpermafrost environment from a surface-drilled borehole. Using a U-tube, gas and water samples were collected, along with temperature, pressure, and hydraulic conductivity measurements, 420 m below ground surface, within a 535 m long, angled borehole at High Lake, Nunavut, Canada, in an area with 460-m-thick permafrost. Piezometric head was well above the base of the permafrost, near land surface. Initial water samples were contaminated with drill fluid, with later samples <40% drill fluid. The salinity of the non-drill fluid component was <20,000 mg/L, had a Ca/Na ratio above 1, with ??18O values ???5??? lower than the local surface water. The fluid isotopic composition was affected by the permafrost-formation process. Nonbacteriogenic CH4 was present and the sample location was within methane hydrate stability field. Sampling lines froze before uncontaminated samples from the subpermafrost environment could be obtained, yet the available time to obtain water samples was extended compared to previous studies. Temperature measurements collected from a distributed temperature sensor indicated that this issue can be overcome easily in the future. The lack of methanogenic CH4 is consistent with the high sulfate concentrations observed in cores. The combined surface-drilled borehole/U-tube approach can provide a large amount of physical, chemical, and microbial data from the subpermafrost environment with few, controllable, sources of contamination. ?? 2010 The Author(s). Journal compilation ?? 2010 National Ground Water Association.

  7. Evaluating Oral Fluid as a Screening Tool for Lead Poisoning.

    PubMed

    Gardner, Sher Lynn; Geller, Robert J; Hannigan, Robyn; Sun, Yu; Mangla, Anil

    2016-11-01

    Screening for lead poisoning is necessary in young children, but obtaining the needed blood sample is unpleasant and sometimes very difficult. Use of an alternative screening method that is less unpleasant and less difficult would likely help to increase the percent of children receiving screening. To evaluate the correlation of oral fluid and blood lead in a clinical setting, and to ascertain the acceptability and feasibility of obtaining oral fluid from a young child in the clinical setting. Oral fluid samples were collected from a convenience sample of 431 children aged 6 months to 5 years already due to receive a blood lead test in a primary care clinic. Blood lead results obtained at the same time were available for 407 children. The results of the two tests were compared with the blood lead test considered to be the "gold standard". Data analysis used Pearson correlations, scatter plots, linear regression, ANOVA and Bland-Altman analysis. 431 patients had oral fluid samples available for analysis, and 407 patients had blood samples available. Patients who had both blood concentrations <5 µg/dL and oral fluid values below the screening cutoff value were 223, while eight had both blood concentrations ≥ 5 µg/dL and oral fluid values above the screening threshold. Elevated oral fluid but blood lead values less than the value recommended for further intervention occurred in 176; no patients had elevated blood lead values with below-intervention oral fluid values. The negative predictive value of an oral fluid lead below the screening cutoff value was 100%. The use of oral fluid to screen for elevated body burdens of lead instead of the usual blood lead sample is feasible with a negative predictive value of 100%, while eliminating the need for blood for lead screening in more than half of these children. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  8. Tissue, Blood, and Body Fluid Sample Collection From Patients With Hematologic Cancer

    ClinicalTrials.gov

    2017-09-20

    Chronic Myeloproliferative Disorders; Leukemia; Lymphoma; Lymphoproliferative Disorder; Multiple Myeloma and Plasma Cell Neoplasm; Myelodysplastic Syndromes; Myelodysplastic/Myeloproliferative Neoplasms; Nonmalignant Neoplasm

  9. A Novel Chronic Opioid Monitoring Tool to Assess Prescription Drug Steady State Levels in Oral Fluid.

    PubMed

    Shaparin, Naum; Mehta, Neel; Kunkel, Frank; Stripp, Richard; Borg, Damon; Kolb, Elizabeth

    2017-11-01

    Interpretation limitations of urine drug testing and the invasiveness of blood toxicology have motivated the desire for the development of simpler methods to assess biologically active drug levels on an individualized patient basis. Oral fluid is a matrix well-suited for the challenge because collections are based on simple noninvasive procedures and drug concentrations better correlate to blood drug levels as oral fluid is a filtrate of the blood. Well-established pharmacokinetic models were utilized to generate oral fluid steady state concentration ranges to assess the interpretive value of the alternative matrix to monitor steady state plasma oxycodone levels. Paired oral fluid and plasma samples were collected from patients chronically prescribed oxycodone and quantitatively analyzed by liquid chromatography tandem mass spectrometry. Steady state plasma concentration ranges were calculated for each donor and converted to an equivalent range in oral fluid. Measured plasma and oral fluid oxycodone concentrations were compared with respective matrix-matched steady state ranges, using each plasma steady state classification as the control. A high degree of correlation was observed between matrices when classifying donors according to expected steady state oxycodone concentration. Agreement between plasma and oral fluid steady state classifications was observed in 75.6% of paired samples. This study supports novel application of basic pharmacokinetic knowledge to the pain management industry, simplifying and improving individualized drug monitoring and risk assessment through the use of oral fluid drug testing. Many benefits of established therapeutic drug monitoring in plasma can be realized in oral fluid for patients chronically prescribed oxycodone at steady state. © 2017 American Academy of Pain Medicine. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  10. 40 CFR 61.242-5 - Standards: Sampling connecting systems.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...) Collect and recycle the purged process fluid; or (3) Be designed and operated to capture and transport all the purged process fluid to a control device that complies with the requirements of § 61.242-11; or (4... operated in compliance with the provisions of 40 CFR part 63, subpart G, applicable to Group 1 wastewater...

  11. 40 CFR 61.242-5 - Standards: Sampling connecting systems.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...) Collect and recycle the purged process fluid; or (3) Be designed and operated to capture and transport all the purged process fluid to a control device that complies with the requirements of § 61.242-11; or (4... operated in compliance with the provisions of 40 CFR part 63, subpart G, applicable to Group 1 wastewater...

  12. Assessment of workers' exposure to microorganisms when using biological degreasing stations.

    PubMed

    Villeneuve, Carol-Anne; Marchand, Geneviève; Gardette, Marie; Lavoie, Jacques; Neesham-Grenon, Eve; Bégin, Denis; Debia, Maximilien

    2018-06-01

    Biological degreasing stations (BDSs) are used by mechanics. These BDSs use a water-based solution with a microbial degradation process. Occupational exposure during the use of BDSs has not been reported and few studies have identified the bacteria present. The objectives were to measure the concentration of microorganisms during BDSs' use and monitor the bacterial community in the liquid over time. Five mechanical workshops were studied. Six 30-min samples were taken at each workshop over one year. Bioaerosols in the ambient air samples were collected with Andersen impactors near the BDS Bioaerosols in the workers' breathing zone (WBZ) were collected on filters. Fresh bio-degreasing fluids were collected from unopened containers, and used bio-degreasing fluids were collected in the BDS. The results show that the use of BDSs does not seem to increase bioaerosols concentrations in the WBZ (concentrations lower than 480 CFU/m 3 ) and that the bacterial communities (mainly yeasts, Bacillus subtilis and Pseudomonas aeruginosa) in the bio-degreasing fluids change through time and differ from the original community (B. subtilis). This study established that workers using BDSs were exposed to low levels of bioaerosols. No respiratory protection is recommended based on bioaerosols concentrations, but gloves and strict personal hygiene practices are essential. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. Determination of As concentration in earthworm coelomic fluid extracts by total-reflection X-ray fluorescence spectrometry

    NASA Astrophysics Data System (ADS)

    Allegretta, Ignazio; Porfido, Carlo; Panzarino, Onofrio; Fontanella, Maria Chiara; Beone, Gian Maria; Spagnuolo, Matteo; Terzano, Roberto

    2017-04-01

    Earthworms are often used as sentinel organisms to study As bioavailability in polluted soils. Arsenic in earthworms is mainly sequestrated in the coelomic fluids whose As content can therefore be used to asses As bioavalability. In this work, a method for determining As concentration in coelomic fluid extracts using total-reflection X-ray fluorescence spectrometry (TXRF) is presented. For this purpose coelomic fluid extracts from earthworms living in three polluted soils and one non-polluted (control) soil have been collected and analysed. A very simple sample preparation was implemented, consisting of a dilution of the extracts with polyvinyl alcohol (PVA) using a 1:8 ratio and dropwise deposition of the sample on the reflector. A detection limit of 0.2 μg/l and quantification limit of 0.6 μg/l was obtained in the diluted samples, corresponding to 2 μg/l and 6 μg/l in the coelomic fluid extracts, respectively. This allowed to quantify As concentration in coelomic fluids extracted from earthworms living in soils polluted with As at concentrations higher than 20 mg/kg (considered as a pollution threshold for agricultural soils). The TXRF method has been validated by comparison with As concentrations in standards and by analysing the same samples by ICP-MS, after acid digestion of the sample. The low limit of detection, the proven reliability of the method and the little sample preparation make TXRF a suitable, cost-efficient and "green" technique for the analysis of As in earthworm coelomic fluid extracts for bioavailability studies.

  14. Evaluation of haemoglobin in blister fluid as an indicator of paediatric burn wound depth.

    PubMed

    Tanzer, Catherine; Sampson, Dayle L; Broadbent, James A; Cuttle, Leila; Kempf, Margit; Kimble, Roy M; Upton, Zee; Parker, Tony J

    2015-08-01

    The early and accurate assessment of burns is essential to inform patient treatment regimens; however, this first critical step in clinical practice remains a challenge for specialist burns clinicians worldwide. In this regard, protein biomarkers are a potential adjunct diagnostic tool to assist experienced clinical judgement. Free circulating haemoglobin has previously shown some promise as an indicator of burn depth in a murine animal model. Using blister fluid collected from paediatric burn patients, haemoglobin abundance was measured using semi-quantitative Western blot and immunoassays. Although a trend was observed in which haemoglobin abundance increased with burn wound severity, several patient samples deviated significantly from this trend. Further, it was found that haemoglobin concentration decreased significantly when whole cells, cell debris and fibrinous matrix was removed from the blister fluid by centrifugation; although the relationship to depth was still present. Statistical analyses showed that haemoglobin abundance in the fluid was more strongly related to the time between injury and sample collection and the time taken for spontaneous re-epithelialisation. We hypothesise that prolonged exposure to the blister fluid microenvironment may result in an increased haemoglobin abundance due to erythrocyte lysis, and delayed wound healing. Copyright © 2015 Elsevier Ltd and ISBI. All rights reserved.

  15. Impact of Reservoir Fluid Saturation on Seismic Parameters: Endrod Gas Field, Hungary

    NASA Astrophysics Data System (ADS)

    El Sayed, Abdel Moktader A.; El Sayed, Nahla A.

    2017-12-01

    Outlining the reservoir fluid types and saturation is the main object of the present research work. 37 core samples were collected from three different gas bearing zones in the Endrod gas field in Hungary. These samples are belonging to the Miocene and the Upper - Lower Pliocene. These samples were prepared and laboratory measurements were conducted. Compression and shear wave velocity were measured using the Sonic Viewer-170-OYO. The sonic velocities were measured at the frequencies of 63 and 33 kHz for compressional and shear wave respectively. All samples were subjected to complete petrophysical investigations. Sonic velocities and mechanical parameters such as young’s modulus, rigidity, and bulk modulus were measured when samples were saturated by 100%-75%-0% brine water. Several plots have been performed to show the relationship between seismic parameters and saturation percentages. Robust relationships were obtained, showing the impact of fluid saturation on seismic parameters. Seismic velocity, Poisson’s ratio, bulk modulus and rigidity prove to be applicable during hydrocarbon exploration or production stages. Relationships among the measured seismic parameters in gas/water fully and partially saturated samples are useful to outline the fluid type and saturation percentage especially in gas/water transitional zones.

  16. Handling and storage of human body fluids for analysis of extracellular vesicles

    PubMed Central

    Yuana, Yuana; Böing, Anita N.; Grootemaat, Anita E.; van der Pol, Edwin; Hau, Chi M.; Cizmar, Petr; Buhr, Egbert; Sturk, Auguste; Nieuwland, Rienk

    2015-01-01

    Because procedures of handling and storage of body fluids affect numbers and composition of extracellular vesicles (EVs), standardization is important to ensure reliable and comparable measurements of EVs in a clinical environment. We aimed to develop standard protocols for handling and storage of human body fluids for EV analysis. Conditions such as centrifugation, single freeze–thaw cycle, effect of time delay between blood collection and plasma preparation and storage were investigated. Plasma is the most commonly studied body fluid in EV research. We mainly focused on EVs originating from platelets and erythrocytes and investigated the behaviour of these 2 types of EVs independently as well as in plasma samples of healthy subjects. EVs in urine and saliva were also studied for comparison. All samples were analysed simultaneously before and after freeze–thawing by resistive pulse sensing, nanoparticle tracking analysis, conventional flow cytometry (FCM) and transmission (scanning) electron microscopy. Our main finding is that the effect of centrifugation markedly depends on the cellular origin of EVs. Whereas erythrocyte EVs remain present as single EVs after centrifugation, platelet EVs form aggregates, which affect their measured concentration in plasma. Single erythrocyte and platelet EVs are present mainly in the range of 100–200 nm, far below the lower limit of what can be measured by conventional FCM. Furthermore, the effects of single freeze–thaw cycle, time delay between blood collection and plasma preparation up to 1 hour and storage up to 1 year are insignificant (p>0.05) on the measured concentration and diameter of EVs from erythrocyte and platelet concentrates and EVs in plasma, urine and saliva. In conclusion, in standard protocols for EV studies, centrifugation to isolate EVs from collected body fluids should be avoided. Freezing and storage of collected body fluids, albeit their insignificant effects, should be performed identically for comparative EV studies and to create reliable biorepositories. PMID:26563735

  17. Handling and storage of human body fluids for analysis of extracellular vesicles.

    PubMed

    Yuana, Yuana; Böing, Anita N; Grootemaat, Anita E; van der Pol, Edwin; Hau, Chi M; Cizmar, Petr; Buhr, Egbert; Sturk, Auguste; Nieuwland, Rienk

    2015-01-01

    Because procedures of handling and storage of body fluids affect numbers and composition of extracellular vesicles (EVs), standardization is important to ensure reliable and comparable measurements of EVs in a clinical environment. We aimed to develop standard protocols for handling and storage of human body fluids for EV analysis. Conditions such as centrifugation, single freeze-thaw cycle, effect of time delay between blood collection and plasma preparation and storage were investigated. Plasma is the most commonly studied body fluid in EV research. We mainly focused on EVs originating from platelets and erythrocytes and investigated the behaviour of these 2 types of EVs independently as well as in plasma samples of healthy subjects. EVs in urine and saliva were also studied for comparison. All samples were analysed simultaneously before and after freeze-thawing by resistive pulse sensing, nanoparticle tracking analysis, conventional flow cytometry (FCM) and transmission (scanning) electron microscopy. Our main finding is that the effect of centrifugation markedly depends on the cellular origin of EVs. Whereas erythrocyte EVs remain present as single EVs after centrifugation, platelet EVs form aggregates, which affect their measured concentration in plasma. Single erythrocyte and platelet EVs are present mainly in the range of 100-200 nm, far below the lower limit of what can be measured by conventional FCM. Furthermore, the effects of single freeze-thaw cycle, time delay between blood collection and plasma preparation up to 1 hour and storage up to 1 year are insignificant (p>0.05) on the measured concentration and diameter of EVs from erythrocyte and platelet concentrates and EVs in plasma, urine and saliva. In conclusion, in standard protocols for EV studies, centrifugation to isolate EVs from collected body fluids should be avoided. Freezing and storage of collected body fluids, albeit their insignificant effects, should be performed identically for comparative EV studies and to create reliable biorepositories.

  18. Shedding of Japanese Encephalitis Virus in Oral Fluid of Infected Swine.

    PubMed

    Lyons, Amy C; Huang, Yan-Jang S; Park, So Lee; Ayers, Victoria B; Hettenbach, Susan M; Higgs, Stephen; McVey, D Scott; Noronha, Leela; Hsu, Wei-Wen; Vanlandingham, Dana L

    2018-05-09

    Japanese encephalitis virus (JEV) is a zoonotic mosquito-borne flavivirus endemic in the Asia-Pacific region. Maintenance of JEV in nature involves enzootic transmission by competent Culex mosquitoes among susceptible avian and swine species. Historically, JEV has been regarded as one of the most important arthropod-borne viruses in Southeast Asia. Oronasal shedding of JEV from infected amplification hosts was not recognized until the recent discovery of vector-free transmission of JEV among domestic pigs. In this study, oral shedding of JEV was characterized in domestic pigs and miniature swine representing the feral phenotype. A rope-based sampling method followed by the detection of viral RNA using RT-qPCR allowed the collection and detection of JEV in oral fluid samples collected from intradermally challenged animals. The results suggest that the shedding of JEV in oral fluid can be readily detected by molecular diagnostic assays at the acute phase of infection. It also demonstrates the feasibility of this technique for the diagnosis and surveillance of JEV in swine species.

  19. Quantitative determination of methamphetamine in oral fluid by liquid-liquid extraction and gas chromatography/mass spectrometry.

    PubMed

    Bahmanabadi, L; Akhgari, M; Jokar, F; Sadeghi, H B

    2017-02-01

    Methamphetamine abuse is one of the most medical and social problems many countries face. In spite of the ban on the use of methamphetamine, it is widely available in Iran's drug black market. There are many analytical methods for the detection of methamphetamine in biological specimen. Oral fluid has become a popular specimen to test for the presence of methamphetamine. The purpose of the present study was to develop a method for the extraction and detection of methamphetamine in oral fluid samples using liquid-liquid extraction (LLE) and gas chromatography/mass spectrometry (GC/MS) methods. An analytical study was designed in that blank and 50 authentic oral fluid samples were collected to be first extracted by LLE and subsequently analysed by GC/MS. The method was fully validated and showed an excellent intra- and inter-assay precision (reflex sympathetic dystrophy ˂ 10%) for external quality control samples. Recovery with LLE methods was 96%. Limit of detection and limit of quantitation were 5 and 15 ng/mL, respectively. The method showed high selectivity, no additional peak due to interfering substances in samples was observed. The introduced method was sensitive, accurate and precise enough for the extraction of methamphetamine from oral fluid samples in forensic toxicology laboratories.

  20. Interleukin-8 mRNA expression in synovial fluid of canine stifle joints with osteoarthritis.

    PubMed

    de Bruin, T; de Rooster, H; van Bree, H; Cox, E

    2005-12-15

    The objective of this study was to examine and compare the presence of interleukin (IL)-8 mRNA in canine stifle osteoarthritis (OA) differing in etiopathogenesis. Synovial fluid (SF) samples were collected from 24 clinically normal stifle joints and 46 diseased stifle joints (32 stifle joints with cranial cruciate ligament rupture (CCLR), 2 joints with CCLR and patella luxation (PL), 7 joints with medial PL and 5 joints with primary OA). The samples were centrifuged to collect synovial fluid cells for RNA extraction. Reverse transcription polymerase chain reaction (RT-PCR) was performed to obtain cDNA from all samples. Canine IL-8 mRNA expression was determined using real time PCR. Synovial fluid glass smears were made of all samples and coloured with H&E for differential cell counts. All stifle joints were radiographed and graded for the severity of OA. Sixty-one percent (28/46) of the samples from canine stifle OA had IL-8 mRNA expression in contrast to 4% (1/24) in the control stifle joints. This difference in prevalence is highly significant. There were no statistically significant pairwise differences among the mean ranks of the various OA groups for the absolute amount of IL-8 mRNA expression. Neither was there a link between the severity of OA (determined by radiographic evaluation) and the presence of IL-8 in the SF nor any significant difference in the absolute amount of IL-8 between the different OA grades. No statistical difference was found in differential cell counts between IL-8-positive and -negative SF samples. IL-8 cannot be used as a specific joint disease marker since IL-8 expression is found in OA differing in etiopathogenesis. It might, however, relate to the ongoing inflammation within the joint.

  1. MEASUREMENTS OF AIR POLLUTANT BIOMARKERS WITH EXHALED BREATH TECHNIQUES

    EPA Science Inventory

    Use of exhaled breath condensate (EBC) has appeal as a noninvasive surrogate sample for lung-derived fluid. Additionally, EBC can be collected multiple times over the course of a study, unlike many other lung sampling techniques which can be performed fewer times. However validat...

  2. Use of FTA filter paper for the molecular detection of Newcastle disease virus.

    PubMed

    Perozo, Francisco; Villegas, Pedro; Estevez, Carlos; Alvarado, Iván; Purvis, Linda B

    2006-04-01

    The feasibility of using Flinders Technology Associates filter papers (FTA cards) to collect allantoic fluid and chicken tissue samples for Newcastle disease virus (NDV) molecular detection was evaluated. Trizol RNA extraction and one-step reverse transcriptase-polymerase chain reaction (RT-PCR) were used. FTA cards allowed NDV identification from allantoic fluid with a titre of 10(5.8) median embryo lethal doses/ml. The inactivated virus remained stable on the cards for 15 days. NDV was detected from FTA imprints of the trachea, lung, caecal tonsil and cloacal faeces of experimentally infected birds. RT-PCR detection from FTA cards was confirmed by homologous frozen-tissue RT-PCR and virus isolation. Direct nucleotide sequence of the amplified F gene allowed prediction of NDV virulence. No virus isolation was possible from the FTA inactivated samples, indicating viral inactivation upon contact. The FTA cards are suitable for collecting and transporting NDV-positive samples, providing a reliable source of RNA for molecular characterization and a hazard-free sample.

  3. Hydraulically controlled discrete sampling from open boreholes

    USGS Publications Warehouse

    Harte, Philip T.

    2013-01-01

    Groundwater sampling from open boreholes in fractured-rock aquifers is particularly challenging because of mixing and dilution of fluid within the borehole from multiple fractures. This note presents an alternative to traditional sampling in open boreholes with packer assemblies. The alternative system called ZONFLO (zonal flow) is based on hydraulic control of borehole flow conditions. Fluid from discrete fractures zones are hydraulically isolated allowing for the collection of representative samples. In rough-faced open boreholes and formations with less competent rock, hydraulic containment may offer an attractive alternative to physical containment with packers. Preliminary test results indicate a discrete zone can be effectively hydraulically isolated from other zones within a borehole for the purpose of groundwater sampling using this new method.

  4. Polar organic compounds in pore waters of the Chesapeake Bay impact structure, Eyreville core hole: Character of the dissolved organic carbon and comparison with drilling fluids

    USGS Publications Warehouse

    Rostad, C.E.; Sanford, W.E.

    2009-01-01

    Pore waters from the Chesapeake Bay impact structure cores recovered at Eyreville Farm, Northampton County, Virginia, were analyzed to characterize the dissolved organic carbon. After squeezing or centrifuging, a small volume of pore water, 100 ??L, was taken for analysis by electrospray ionization-mass spectrometry. Porewater samples were analyzed directly without filtration or fractionation, in positive and negative mode, for polar organic compounds. Spectra in both modes were dominated by low-molecular-weight ions. Negative mode had clusters of ions differing by -60 daltons, possibly due to increasing concentrations of inorganic salts. The numberaverage molecular weight and weight-average molecular weight values for the pore waters from the Chesapeake Bay impact structure are higher than those reported for other aquatic sources of natural dissolved organic carbon as determined by electrospray ionization-mass spectrometry. In order to address the question of whether drilling mud fluids may have contaminated the pore waters during sample collection, spectra from the pore waters were compared to spectra from drilling mud fluids. Ions indicative of drilling mud fluids were not found in spectra from the pore waters, indicating there was no detectable contamination, and highlighting the usefulness of this analytical technique for detecting potential contamination during sample collection. ?? 2009 The Geological Society of America.

  5. Alzheimer's disease cerebrospinal fluid biomarkers are not influenced by gravity drip or aspiration extraction methodology.

    PubMed

    Rembach, Alan; Evered, Lisbeth A; Li, Qiao-Xin; Nash, Tabitha; Vidaurre, Lesley; Fowler, Christopher J; Pertile, Kelly K; Rumble, Rebecca L; Trounson, Brett O; Maher, Sarah; Mooney, Francis; Farrow, Maree; Taddei, Kevin; Rainey-Smith, Stephanie; Laws, Simon M; Macaulay, S Lance; Wilson, William; Darby, David G; Martins, Ralph N; Ames, David; Collins, Steven; Silbert, Brendan; Masters, Colin L; Doecke, James D

    2015-11-19

    Cerebrospinal fluid (CSF) biomarkers, although of established utility in the diagnostic evaluation of Alzheimer's disease (AD), are known to be sensitive to variation based on pre-analytical sample processing. We assessed whether gravity droplet collection versus syringe aspiration was another factor influencing CSF biomarker analyte concentrations and reproducibility. Standardized lumbar puncture using small calibre atraumatic spinal needles and CSF collection using gravity fed collection followed by syringe aspirated extraction was performed in a sample of elderly individuals participating in a large long-term observational research trial. Analyte assay concentrations were compared. For the 44 total paired samples of gravity collection and aspiration, reproducibility was high for biomarker CSF analyte assay concentrations (concordance correlation [95%CI]: beta-amyloid1-42 (Aβ42) 0.83 [0.71 - 0.90]), t-tau 0.99 [0.98 - 0.99], and phosphorylated tau (p-tau) 0.82 [95 % CI 0.71 - 0.89]) and Bonferroni corrected paired sample t-tests showed no significant differences (group means (SD): Aβ42 366.5 (86.8) vs 354.3 (82.6), p = 0.10; t-tau 83.9 (46.6) vs 84.7 (47.4) p = 0.49; p-tau 43.5 (22.8) vs 40.0 (17.7), p = 0.05). The mean duration of collection was 10.9 minutes for gravity collection and <1 minute for aspiration. Our results demonstrate that aspiration of CSF is comparable to gravity droplet collection for AD biomarker analyses but could considerably accelerate throughput and improve the procedural tolerability for assessment of CSF biomarkers.

  6. Microbial Life in Ridge Flank Crustal Fluids at Baby Bare Seamount, Juan de Fuca Ridge

    NASA Astrophysics Data System (ADS)

    Huber, J. A.; Johnson, H. P.; Butterfield, D. A.; Baross, J. A.

    2005-12-01

    To determine the microbial community diversity within old oceanic crust, a novel sampling strategy was used to collect crustal fluids at Baby Bare Seamount, a 3.5 Ma old outcrop located in the northeast Pacific Ocean on the eastern flank of the Juan de Fuca Ridge. Stainless steel probes were driven directly into the igneous ocean crust to obtain samples of ridge flank crustal fluids. Genetic signatures and enrichment cultures of microorganisms demonstrate that these crustal fluids host a microbial community composed of species indigenous to the subseafloor, including anaerobic thermophiles, and species from other deep-sea habitats, such as seawater and sediments. Evidence using molecular techniques indicates the presence of a relatively small but active microbial population, dominated by bacteria. The microbial community diversity found in the crustal fluids may indicate habitat variability in old oceanic crust, with inputs of nutrients from seawater, sediment pore-water fluids and possibly hydrothermal sources. This report further supports the presence of an indigenous microbial community in ridge flank crustal fluids and advances our understanding of the potential physiological and phylogenetic diversity of this community.

  7. Serum, tissue and body fluid concentrations of tigecycline after a single 100 mg dose.

    PubMed

    Rodvold, Keith A; Gotfried, Mark H; Cwik, Michael; Korth-Bradley, Joan M; Dukart, Gary; Ellis-Grosse, Evelyn J

    2006-12-01

    The purpose of this study was to determine the tissue and corresponding serum concentration of tigecycline at selected time points in gall bladder, bile, colon, bone, synovial fluid (SF), lung and CSF in subjects undergoing surgical or medical procedures. One hundred and four adult subjects (aged 24-83 years; 64 women, 40 men) received a single intravenous (i.v.) dose of tigecycline (100 mg infused over 30 min). Subjects were randomly assigned to one of four collection times at 4, 8, 12 and 24 h after the start of the infusion. For CSF, samples were collected at approximately 1.5 and 24 h after the start of the infusion. All subjects had serum samples collected before the administration of tigecycline, at the end of the infusion and at the time corresponding to tissue or body fluid collection. Drug concentrations in serum, tissues and body fluids were determined by LC/MS/MS. The area under the mean concentration-time curve from 0 to 24 h (AUC(0-24)) was determined for the comparison of systemic exposure between tissue or body fluid to serum. The mean serum concentrations of tigecycline were similar to those previously published. Tissue penetration, expressed as the ratio of AUC(0-24) in tissue or body fluid to serum, was 537 for bile, 23 for gall bladder, 2.6 for colon, 2.0 for lung, 0.41 for bone, 0.31 for SF and 0.11 for CSF. A single 100 mg dose of intravenous tigecycline produced considerably higher tissue/fluid concentrations in bile, gall bladder, colon and lung compared with simultaneous serum concentrations. On average, the systemic exposure of tigecycline in bone, SF and CSF ranged from 11% to 41% of serum concentrations. The results in bone are inconsistent with previous radiolabelled studies in animals and it is unclear if tight binding to bone (versus low bone uptake) or poor extraction of tigecycline for LC/MS/MS detection or both may have contributed to the differences we observed in humans.

  8. Contamination Control of Freeze Shoe Coring System for Collection of Aquifer Sands

    NASA Astrophysics Data System (ADS)

    Homola, K.; van Geen, A.; Spivack, A. J.; Grzybowski, B.; Schlottenmier, D.

    2017-12-01

    We have developed and tested an original device, the freeze-shoe coring system, designed to recover undisturbed samples of water contained in sand-dominated aquifers. Aquifer sands are notoriously difficult to collect together with porewater from coincident depths, as high hydraulic permeability leads to water drainage and mixing during retrieval. Two existing corer designs were reconfigured to incorporate the freeze-shoe system; a Hydraulic Piston (HPC) and a Rotary (RC) Corer. Once deployed, liquid CO­2 contained in an interior tank is channeled to coils at the core head where it changes phase, rapidly cooling the deepest portion of the core. The resulting frozen core material impedes water loss during recovery. We conducted contamination tests to examine the integrity of cores retrieved during a March 2017 yard test deployment. Perfluorocarbon tracer (PFC) was added to the drill fluid and recovered cores were subsampled to capture the distribution of PFC throughout the core length and interior. Samples were collected from two HPC and one RC core and analyzed for PFC concentrations. The lowest porewater contamination, around 0.01% invasive fluid, occurs in the center of both HPC cores. The greatest contamination (up to 10%) occurs at the disturbed edges where core material contacts drill fluid. There was lower contamination in the core interior than top, bottom, and edges, as well as significantly lower contamination in HPC cores that those recovered with the RC. These results confirm that the freeze-shoe system, proposed for field test deployments in West Bengal, India, can successfully collect intact porewater and sediment material with minimal if any contamination from drill fluid.

  9. Utah: basic data for thermal springs and wells as recorded in GEOTHERM

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bliss, J.D.

    1983-05-01

    This GEOTHERM sample file contains 643 records for Utah. Records may be present which are duplicates for the same analyses. A record may contain data on location, sample description, analysis type (water, condensate, or gas), collection condition, flow rates, and the chemical and physical properties of the fluid. Stable and radioactive isotopic data are occasionally available. Some records may contain only location and temperature. This compilation should contain all the chemical data for geothermal fluids in Utah available as of December, 1981. 7 refs. (ACR)

  10. An acoustic on-chip goniometer for room temperature macromolecular crystallography.

    PubMed

    Burton, C G; Axford, D; Edwards, A M J; Gildea, R J; Morris, R H; Newton, M I; Orville, A M; Prince, M; Topham, P D; Docker, P T

    2017-12-05

    This paper describes the design, development and successful use of an on-chip goniometer for room-temperature macromolecular crystallography via acoustically induced rotations. We present for the first time a low cost, rate-tunable, acoustic actuator for gradual in-fluid sample reorientation about varying axes and its utilisation for protein structure determination on a synchrotron beamline. The device enables the efficient collection of diffraction data via a rotation method from a sample within a surface confined droplet. This method facilitates efficient macromolecular structural data acquisition in fluid environments for dynamical studies.

  11. Sterile Reverse Osmosis Water Combined with Friction Are Optimal for Channel and Lever Cavity Sample Collection of Flexible Duodenoscopes.

    PubMed

    Alfa, Michelle J; Singh, Harminder; Nugent, Zoann; Duerksen, Donald; Schultz, Gale; Reidy, Carol; DeGagne, Patricia; Olson, Nancy

    2017-01-01

    Simulated-use buildup biofilm (BBF) model was used to assess various extraction fluids and friction methods to determine the optimal sample collection method for polytetrafluorethylene channels. In addition, simulated-use testing was performed for the channel and lever cavity of duodenoscopes. BBF was formed in polytetrafluorethylene channels using Enterococcus faecalis, Escherichia coli , and Pseudomonas aeruginosa . Sterile reverse osmosis (RO) water, and phosphate-buffered saline with and without Tween80 as well as two neutralizing broths (Letheen and Dey-Engley) were each assessed with and without friction. Neutralizer was added immediately after sample collection and samples concentrated using centrifugation. Simulated-use testing was done using TJF-Q180V and JF-140F Olympus duodenoscopes. Despite variability in the bacterial CFU in the BBF model, none of the extraction fluids tested were significantly better than RO. Borescope examination showed far less residual material when friction was part of the extraction protocol. The RO for flush-brush-flush (FBF) extraction provided significantly better recovery of E. coli ( p  = 0.02) from duodenoscope lever cavities compared to the CDC flush method. We recommend RO with friction for FBF extraction of the channel and lever cavity of duodenoscopes. Neutralizer and sample concentration optimize recovery of viable bacteria on culture.

  12. Isotretinoin in lacrimal gland fluid and tears.

    PubMed

    Rismondo, V; Ubels, J L

    1987-03-01

    Isotretinoin (13-cis-retinoic acid) is used in the treatment of severe cystic acne. Adverse ocular reactions, including blepharoconjunctivitis and dry eye symptoms, are frequent side effects of this drug. Our previous observation that retinol is present in tears and lacrimal gland fluid suggests that isotretinoin may also be secreted by the lacrimal gland. Rabbits were treated with isotretinoin, and lacrimal gland fluid was collected from the cannulated lacrimal gland duct. Tears were collected from patients who were being treated with isotretinoin. Lacrimal gland fluid and tears were analyzed by reverse-phase high-pressure liquid chromatography and a peak eluted from each sample, which was identified as isotretinoin. We conclude that the lacrimal gland is able to secrete isotretinoin in addition to retinol and that, in animals and patients treated systemically with isotretinoin, the ocular surface is exposed to the drug via the tear film.

  13. On the fate of arsenic in the Menez Gwen hydrothermal system, Mid-Atlantic Ridge

    NASA Astrophysics Data System (ADS)

    Breuer, C.; Ruiz Chancho, M.; Pichler, T.

    2011-12-01

    Samples of hydrothermal fluids and on-site associated mussels (Bathymodiolus azoricus) were collected during the M 82/3 cruise of RV Meteor at the Menez Gwen hydrothermal field (37° 50' N, MAR) and analyzed for total and arsenic species (arsenite, arsenate and organorarsenicals) with ICP-(HR)MS and HPLC-ICP-(HR)MS respectively. Fluids emitting with temperatures of up to 280 °C and at 840 - 865 m depth contained total endmember As concentrations between 9.5 and 19.23 μg L-1 while local seawater concentrations varied around 1.5 μg L-1. The most important factors controlling the amount of As in these fluids are the E-MORB host rock composition and temperature of the fluids leading to phase separation or not. Regarding arsenic speciation in the fluids, there is discrepancy about the best method of preservation for water samples when speciation analysis of arsenic species must be carried out and a lack of information is especially relevant when marine hydrothermal vent samples have to be preserved. For this, one of the objectives of the present study was the comparison of different preservation methods of fluid samples collected at the Menez Gwen hydrothermal field. The methods used in the present study were: freezing at -20 °C, acidification with HCl and addition of EDTA. Most of these have been used by different authors for the preservation of inorganic arsenic species but organic arsenic species have not been taken into account and particularly hydrothermal fluids were not investigated. The results show very different proportions of arsenite and arsenate depending on the preservation procedure but the presence of methylated arsenic species or arsenosugars was not detected. The highest proportions of arsenite were found in the samples preserved with HCl. The presence of thio-arsenic species was tested with the addition of hydrogen peroxide. Moreover, mass balance calculations showed the presence of one or more species, which could not be detected with the chromatographic separation used in the present study. It was also observed that there was a strong T and pH dependence with arsenite, especially in the flash frozen samples. From this study it can be clearly stated that sample preservation is a critical point and further studies related with preservation of marine hydrothermal vent fluids for arsenic speciation must be carried out. Although arsenic has been extensively investigated in marine organisms, there is still little information about the metabolism of this element in organisms habiting the deep see, with only one publication so far. Bathymodiolus azoricus has never been studied regarding arsenic speciation and the fact that it is exposed to arsenic concentrations higher than other marine organisms makes it very interesting from the metabolism point of view. The mussels collected near the vents were dissected in gill, muscle and digestive gland and analyzed for total and arsenic species. Results are discussed taking into account the exposure and possible metabolism paths taking place in deep-sea hydrothermal systems.

  14. Mass spectrometry profiling of oxylipins, endocannabinoids, and N-acylethanolamines in human lung lavage fluids reveals responsiveness of prostaglandin E2 and associated lipid metabolites to biodiesel exhaust exposure.

    PubMed

    Gouveia-Figueira, Sandra; Karimpour, Masoumeh; Bosson, Jenny A; Blomberg, Anders; Unosson, Jon; Pourazar, Jamshid; Sandström, Thomas; Behndig, Annelie F; Nording, Malin L

    2017-04-01

    The adverse effects of petrodiesel exhaust exposure on the cardiovascular and respiratory systems are well recognized. While biofuels such as rapeseed methyl ester (RME) biodiesel may have ecological advantages, the exhaust generated may cause adverse health effects. In the current study, we investigated the responses of bioactive lipid mediators in human airways after biodiesel exhaust exposure using lipidomic profiling methods. Lipid mediator levels in lung lavage were assessed following 1-h biodiesel exhaust (average particulate matter concentration, 159 μg/m 3 ) or filtered air exposure in 15 healthy individuals in a double-blinded, randomized, controlled, crossover study design. Bronchoscopy was performed 6 h post exposure and lung lavage fluids, i.e., bronchial wash (BW) and bronchoalveolar lavage (BAL), were sequentially collected. Mass spectrometry methods were used to detect a wide array of oxylipins (including eicosanoids), endocannabinoids, N-acylethanolamines, and related lipid metabolites in the collected BW and BAL samples. Six lipids in the human lung lavage samples were altered following biodiesel exhaust exposure, three from BAL samples and three from BW samples. Of these, elevated levels of PGE 2 , 12,13-DiHOME, and 13-HODE, all of which were found in BAL samples, reached Bonferroni-corrected significance. This is the first study in humans reporting responses of bioactive lipids following biodiesel exhaust exposure and the most pronounced responses were seen in the more peripheral and alveolar lung compartments, reflected by BAL collection. Since the responsiveness and diagnostic value of a subset of the studied lipid metabolites were established in lavage fluids, we conclude that our mass spectrometry profiling method is useful to assess effects of human exposure to vehicle exhaust.

  15. Smart fast blood counting of trace volumes of body fluids from various mammalian species using a compact custom-built microscope cytometer (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Smith, Zachary J.; Gao, Tingjuan; Lin, Tzu-Yin; Carrade-Holt, Danielle; Lane, Stephen M.; Matthews, Dennis L.; Dwyre, Denis M.; Wachsmann-Hogiu, Sebastian

    2016-03-01

    Cell counting in human body fluids such as blood, urine, and CSF is a critical step in the diagnostic process for many diseases. Current automated methods for cell counting are based on flow cytometry systems. However, these automated methods are bulky, costly, require significant user expertise, and are not well suited to counting cells in fluids other than blood. Therefore, their use is limited to large central laboratories that process enough volume of blood to recoup the significant capital investment these instruments require. We present in this talk a combination of a (1) low-cost microscope system, (2) simple sample preparation method, and (3) fully automated analysis designed for providing cell counts in blood and body fluids. We show results on both humans and companion and farm animals, showing that accurate red cell, white cell, and platelet counts, as well as hemoglobin concentration, can be accurately obtained in blood, as well as a 3-part white cell differential in human samples. We can also accurately count red and white cells in body fluids with a limit of detection ~3 orders of magnitude smaller than current automated instruments. This method uses less than 1 microliter of blood, and less than 5 microliters of body fluids to make its measurements, making it highly compatible with finger-stick style collections, as well as appropriate for small animals such as laboratory mice where larger volume blood collections are dangerous to the animal's health.

  16. A pilot study comparing the effect of orally administered esomeprazole and omeprazole on gastric fluid pH in horses.

    PubMed

    Huxford, K E; Dart, A J; Perkins, N R; Bell, R; Jeffcott, L B

    2017-11-01

    AIMS To compare the efficacy of an enteric coated esomeprazole paste with an enteric coated omeprazole paste to increase gastric pH after oral administration in horses. METHODS Nine adult Standardbred horses were randomly assigned to three groups, each containing three horses, for a study comprising three phases of 10 days, with an 18-day washout period between each phase. In each phase, three horses received either 0.5 mg/kg esomeprazole, 1 mg/kg omeprazole or a placebo, as an oral paste, once daily for 10 days (Days 0-9). Over the course of study all horses received all three treatments. Gastric fluid samples were collected using a gastroscope on Days 1, 3, 5, 8 and 10, with food and water withheld for 16 hours prior to collection of samples. The pH of all samples was measured immediately after collection. RESULTS Mean pH (3.38; SD 1.75) of the gastric fluid samples in the horses that received the placebo was lower than in the horses that received esomeprazole (6.28; SD 1.75) or omeprazole (6.13; SD 1.75) (p<0.001). There was no difference in the mean pH between horses receiving esomeprazole and those receiving omeprazole (p=0.56). CONCLUSIONS AND CLINICAL RELEVANCE Under these study conditions, esomeprazole paste was equally as effective as omeprazole paste in increasing gastric pH in horses. Enteric coated esomeprazole, may be a therapeutic alternative to omeprazole for the prevention of gastric ulcers in horses.

  17. Innovative Ways for Information Transfer in Biobanking

    ERIC Educational Resources Information Center

    Macheiner, Tanja; Huppertz, Berthold; Sargsyan, Karine

    2013-01-01

    Purpose: Biobanks are collections of biological samples (e.g. tissue samples and body fluids) and their associated data intended for various approaches in medical research. The field of biobanking evolves rapidly as an interdisciplinary branch of research and requires educational efforts to provide skilled experts in Europe and beyond. New ways in…

  18. 40 CFR 63.1013 - Sampling connection systems standards.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... (CONTINUED) National Emission Standards for Equipment Leaks-Control Level 1 § 63.1013 Sampling connection... container are not required to be collected or captured. (c) Equipment design and operation. Each closed... process fluid to a process; or (3) Be designed and operated to capture and transport all the purged...

  19. Transvaginal Drainage of Pelvic Abscesses and Collections Using Transabdominal Ultrasound Guidance.

    PubMed

    Ching, Kevin C; Sumkin, Jules H

    2015-01-01

    Objectives. To evaluate clinical outcomes following transvaginal catheter placement using transabdominal ultrasound guidance for management of pelvic fluid collections. Methods. A retrospective review was performed for all patients who underwent transvaginal catheter drainage of pelvic fluid collections utilizing transabdominal ultrasound guidance between July 2008 and July 2013. 24 consecutive patients were identified and 24 catheters were placed. Results. The mean age of patients was 48.1 years (range = 27-76 y). 88% of collections were postoperative (n = 21), 8% were from pelvic inflammatory disease (n = 2), and 4% were idiopathic (n = 1). Of the 24 patients, 83% of patients (n = 20) had previously undergone a hysterectomy and 1 patient (4%) was pregnant at the time of drainage. The mean volume of initial drainage was 108 mL (range = 5 to 570). Catheters were left in place for an average of 4.3 days (range = 1-17 d). Microbial sampling was performed in all patients with 71% (n = 17) returning a positive culture. All collections were successfully managed percutaneously. There were no technical complications. Conclusions. Transvaginal catheter drainage of pelvic fluid collections using transabdominal ultrasound guidance is a safe and clinically effective procedure. Appropriate percutaneous management can avoid the need for surgery.

  20. Dynamic strength, particle deformation, and fracture within fluids with impact-activated microstructures

    NASA Astrophysics Data System (ADS)

    Petel, Oren E.; Ouellet, Simon

    2017-07-01

    The evolution of material strength within several dense particle suspensions impacted by a projectile is investigated and shown to be strongly dependent on the particle material in suspension. For stronger particles, such as silicon carbide, the shear strength of the fluid is shown to increase with the ballistic impact strength. For weaker particles, such as silica, the shear strength of the suspension is found to be independent of impact strength in this dynamic range of tests. A soft-capture technique is employed to collect ejecta samples of a silica-based shear thickening fluid, following a ballistic impact and penetration event. Ejecta samples that were collected from impacts at three different velocities are observed and compared to the benchmark particles using a Scanning Electron Microscope. The images show evidence of fractured and deformed silica particles recovered among the nominally 1 μm diameter monodisperse spheres. There is also evidence of particle fragments that appear to be the result of interparticle grinding. The trends observed in the shear strength estimates are interpreted with regards to the particle damage seen in the ejecta recovery experiments to develop a concept of the impact response of these fluids. The results suggest that particle slip through deformation is likely the dominant factor in limiting the transient impact strength of these fluids. Particularly, particle strength is important in the formation and collapse of dynamically jammed particle contact networks in the penetration process.

  1. Method and Apparatus for the Collection, Storage, and Real Time Analysis of Blood and Other Bodily Fluids

    NASA Technical Reports Server (NTRS)

    Whiitson, Peggy A. (Inventor); Clift, Vaughan L. (Inventor)

    1999-01-01

    The present invention provides a method and apparatus for separating a blood sample having a volume of up to about 20 milliliters into cellular and acellular fractions. The apparatus includes a housing divided by a fibrous filter into a blood sample collection chamber having a volume of at least about 1 milliliter and a serum sample collection chamber. The fibrous filter has a pore size of less than about 3 microns, and is coated with a mixture including between about 1-40 wt/vol % mannitol and between about 0.1-15 wt/vol % of plasma fraction protein (or an animal or vegetable equivalent thereof). The coating causes the cellular fraction to be trapped by the small pores, leaving the cellular fraction intact on the fibrous filter while the acellular fraction passes through the filter for collection in unaltered form from the serum sample collection chamber.

  2. Heparin-like activity in uterine fluid.

    PubMed Central

    Foley, M E; Griffin, B D; Zuzel, M; Aparicio, S R; Bradbury, K; Bird, C C; Clayton, J K; Jenkins, D M; Scott, J S; Rajah, S M; McNichol, G P

    1978-01-01

    Uterine fluid was collected from a group of normal patients and a group of patients with menorrhagia. Heparin-like activity was detected in 34 out of 38 samples using an anti-Xa heparin assay. The heparin-like activity in uterine fluid was inhibited by adding the heparin antagonist hexadimethrine bromide to the assay. Concentrations of fibrinogen-fibrin degradation products (FDPs) were measured in five samples of uterine fluid. FDPs in the concentration detected had no effect on the anti-Xa assay. Heparin-like activity was higher in the group with menorrhagia, although the differences were not significant. Heparin-like activity increased throughout the menstrual cycle and decreased during menstruation, suggesting a possible cyclical variation in activity. There was no correlation between mast cell numbers in the endometrium and myometrium and heparin-like activity in uterine fluid and no correlation between the numbers and the stage in the menstrual cycle. In a few patients with intrauterine contraceptive devices (IUCDs) heparin-like activity was increased. PMID:687899

  3. Assessment of the stability of DNA in specimens collected under conditions for drug testing-A pilot study.

    PubMed

    White, Robert M; Mitchell, John M; Hart, E Dale; Evans, Amy; Meaders, Meredith; Norsworthy, Sarah E; Hayes, Eugene D; Flegel, Ron; Maha, George C; Shaffer, Megan D; Hall, Erin M; Rogers, Kelley

    2018-02-01

    For forensic biological sample collections, the specimen donor is linked solidly to his or her specimen through a chain of custody (CoC) sometimes referenced as a chain of evidence. Rarely, a donor may deny that a urine or oral fluid (OF) specimen is his or her specimen even with a patent CoC. The goal of this pilot study was to determine the potential effects of short-term storage on the quality and quantity of DNA in both types of specimen under conditions that may be encountered with employment-related drug testing specimens. Fresh urine and freshly collected oral fluid all produced complete STR profiles. For the "pad" type OF collectors, acceptable DNA was extractable both from the buffer/preservative and the pad. Although fresh urine and OF produced complete STR profiles, partial profiles were obtained after storage for most samples. An exception was the DNA in the Quantisal OF collector, from which a complete profile was obtained for both freshly collected OF and stored OF. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Detection of birefringent microcrystals in bile

    DOEpatents

    Darrow, Chris; Mirhej, Andrew; Seger, Tino

    2003-09-30

    A transparent flow channel fluidly communicates a fluid source and a collection reservoir. A light beam passes through a first polarizer having a first plane of polarization. The flow channel is orthogonal to the light beam. The light beam passes through a fluid sample as it flows through the flow channel. The light beam is then filtered through a second polarizer having a second plane of polarization rotated 90.degree. from the first plane of polarization. The birefringence of certain crystalline materials present in the fluid sample rotates the plane of polarization of the light beam. The presence of these microcrystals thus causes a component of the beam to pass through the second polarizer and impinge an electronic photo-detector located in the path of the beam. The photo-detector signals the presence of the microcrystals by generating voltage pulses. A display device visually presents the quantitative results of the assay.

  5. Presence of bile acids in human follicular fluid and their relation with embryo development in modified natural cycle IVF.

    PubMed

    Nagy, R A; van Montfoort, A P A; Dikkers, A; van Echten-Arends, J; Homminga, I; Land, J A; Hoek, A; Tietge, U J F

    2015-05-01

    Are bile acids (BA) and their respective subspecies present in human follicular fluid (FF) and do they relate to embryo quality in modified natural cycle IVF (MNC-IVF)? BA concentrations are 2-fold higher in follicular fluid than in serum and ursodeoxycholic acid (UDCA) derivatives were associated with development of top quality embryos on Day 3 after fertilization. Granulosa cells are capable of synthesizing BA, but a potential correlation with oocyte and embryo quality as well as information on the presence and role of BA subspecies in follicular fluid have yet to be investigated. Between January 2001 and June 2004, follicular fluid and serum samples were collected from 303 patients treated in a single academic centre that was involved in a multicentre cohort study on the effectiveness of MNC-IVF. Material from patients who underwent a first cycle of MNC-IVF was used. Serum was not stored from all patients, and the available material comprised 156 follicular fluid and 116 matching serum samples. Total BA and BA subspecies were measured in follicular fluid and in matching serum by enzymatic fluorimetric assay and liquid chromatography-mass spectrometry, respectively. The association of BA in follicular fluid with oocyte and embryo quality parameters, such as fertilization rate and cell number, presence of multinucleated blastomeres and percentage of fragmentation on Day 3, was analysed. Embryos with eight cells on Day 3 after oocyte retrieval were more likely to originate from follicles with a higher level of UDCA derivatives than those with fewer than eight cells (P < 0.05). Furthermore, follicular fluid levels of chenodeoxycholic derivatives were higher and deoxycholic derivatives were lower in the group of embryos with fragmentation compared with those without (each P < 0.05). Levels of total BA were 2-fold higher in follicular fluid compared with serum (P < 0.001), but had no predictive value for oocyte and embryo quality. Only samples originating from first cycle MNC-IVF were used, which resulted in 14 samples only from women with an ongoing pregnancy, therefore further prospective studies are required to confirm the association of UDCA with IVF pregnancy outcomes. The inter-cycle variability of BA levels in follicular fluid within individuals has yet to be investigated. We checked for macroscopic signs of contamination of follicular fluid by blood but the possibility that small traces of blood were present within the follicular fluid remains. Finally, although BA are considered stable when stored at -20°C, there was a time lag of 10 years between the collection and analysis of follicular fluid and serum samples. The favourable relation between UDCA derivatives in follicular fluid and good embryo development and quality deserves further prospective research, with live birth rates as the end-point. This work was supported by a grant from the Netherlands Organisation for Scientific Research (VIDI Grant 917-56-358 to U.J.F.T.). No competing interests are reported. © The Author 2015. Published by Oxford University Press on behalf of the European Society of Human Reproduction and Embryology. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  6. Quantification of Methylphenidate, Dexamphetamine, and Atomoxetine in Human Serum and Oral Fluid by HPLC With Fluorescence Detection.

    PubMed

    Stegmann, Benedikt; Dörfelt, Anett; Haen, Ekkehard

    2016-02-01

    For psychostimulants, a marked individual variability in the dose-response relationship and large differences in plasma concentrations after similar doses are known. Therefore, optimizing the efficacy of these drugs is at present the most promising way to exploit their full pharmacological potential. Moreover, it seems important to examine oral fluid as less invasive biological matrix for its benefit in therapeutic drug monitoring for patients with hyperkinetic disorder. A high-performance liquid chromatography method for quantification of methylphenidate (MPH), dexamphetamine (DXA), and atomoxetine in serum and oral fluid has been developed and validated. The analytical procedure involves liquid-liquid extraction, derivatization with 4-(4,5-diphenyl-1H-imidazol-2-yl)benzoyl chloride as a label and chromatographic separation on a Phenomenex Gemini-NX C18 analytical column using gradient elution with water-acetonitrile. The derivatized analytes were detected at 330 nm (excitation wavelength) and 440 nm (emission wavelength). To examine the oral fluid/serum ratios, oral fluid samples were collected simultaneously to blood samples from patients with hyperkinetic disorder. The method allows quantification of all analytes in serum and oral fluid within 16 minutes under the same or similar conditions. Oral fluid/serum ratios for MPH and DXA were highly variable and showed an accumulation of these drugs in oral fluid. The developed method covers the determination of MPH, DXA, and atomoxetine concentrations in serum and oral fluid after the intake of therapeutic doses. Oral fluid samples are useful for the qualitative detection of MPH and DXA.

  7. [Analysis of factors related to the number of mesenchymal stem cells derived from synovial fluid of the temporomandibular joint].

    PubMed

    Sun, Y P; Zheng, Y H; Zhang, Z G

    2017-06-09

    Objective: To analyze related factors on the number of mesenchymal stem cells in the synovial fluid of the temporomandibular joint (TMJ) and provide an research basis for understanding of the source and biological role of mesenchymal stem cells derived from synovial fluid in TMJ. Methods: One hundred and twenty-two synovial fluid samples from 91 temporomandibular disorders (TMD) patients who visited in Department of TMJ Center, Guanghua School of Stomatology, Hospital of Stomatology, Sun Yat-sen University from March 2013 to December 2013 were collected in this study, and 6 TMJ synovial fluid samples from 6 normal volunteers who were studying in the North Campus of Sun Yat-sen University were also collected, so did their clinical information. Then the relation between the number of mesenchymal stem cells derived from synovial fluid and the health status of the joints, age of donor, disc perforation, condylar bony destruction, blood containing and visual analogue scale score of pain were investigated using Mann-Whitney U test and Spearman rank correlation test. Results: The number of mesenchymal stem cells derived from synovial fluid had no significant relation with visual analogue scale score of pain ( r= 0.041, P= 0.672), blood containing ( P= 0.063), condylar bony destruction ( P= 0.371). Linear correlation between the number of mesenchymal stem cells derived from synovial fluid and age of donor was very week ( r= 0.186, P= 0.043). The number of mesenchymal stem cells up-regulated when the joint was in a disease state ( P= 0.001). The disc perforation group had more mesenchymal stem cells in synovial fluid than without disc perforation group ( P= 0.042). Conclusions: The number of mesenchymal stem cells derived from synovial fluid in TMJ has no correlation with peripheral blood circulation and condylar bony destruction, while has close relation with soft tissue structure damage of the joint.

  8. Anidulafungin Pharmacokinetics in Ascites Fluid and Pleural Effusion of Critically Ill Patients.

    PubMed

    Welte, R; Eller, P; Lorenz, I; Joannidis, M; Bellmann, R

    2018-04-01

    Anidulafungin concentrations were quantified with high-pressure liquid chromatography (HPLC) and UV detection of the ascites fluid and pleural effusion of 10 adult critically ill patients. Samples were collected from ascites fluid and from pleural drains or during paracentesis and thoracentesis, respectively. Anidulafungin levels in ascites fluid (0.12 to 0.99 μg/ml) and in pleural effusion (0.32 to 2.02 μg/ml) were below the simultaneous levels in plasma (1.04 to 7.70 and 2.48 to 13.36 μg/ml, respectively) and below the MIC values for several pathogenic Candida strains. Copyright © 2018 American Society for Microbiology.

  9. Proteomic analysis of mare follicular fluid during late follicle development

    PubMed Central

    2011-01-01

    Background Follicular fluid accumulates into the antrum of follicle from the early stage of follicle development. Studies on its components may contribute to a better understanding of the mechanisms underlying follicular development and oocyte quality. With this objective, we performed a proteomic analysis of mare follicular fluid. First, we hypothesized that proteins in follicular fluid may differ from those in the serum, and also may change during follicle development. Second, we used four different approaches of Immunodepletion and one enrichment method, in order to overcome the masking effect of high-abundance proteins present in the follicular fluid, and to identify those present in lower abundance. Finally, we compared our results with previous studies performed in mono-ovulant (human) and poly-ovulant (porcine and canine) species in an attempt to identify common and/or species-specific proteins. Methods Follicular fluid samples were collected from ovaries at three different stages of follicle development (early dominant, late dominant and preovulatory). Blood samples were also collected at each time. The proteomic analysis was carried out on crude, depleted and enriched follicular fluid by 2D-PAGE, 1D-PAGE and mass spectrometry. Results Total of 459 protein spots were visualized by 2D-PAGE of crude mare follicular fluid, with no difference among the three physiological stages. Thirty proteins were observed as differentially expressed between serum and follicular fluid. Enrichment method was found to be the most powerful method for detection and identification of low-abundance proteins from follicular fluid. Actually, we were able to identify 18 proteins in the crude follicular fluid, and as many as 113 in the enriched follicular fluid. Inhibins and a few other proteins involved in reproduction could only be identified after enrichment of follicular fluid, demonstrating the power of the method used. The comparison of proteins found in mare follicular fluid with proteins previously identified in human, porcine and canine follicular fluids, led to the identification of 12 common proteins and of several species-specific proteins. Conclusions This study provides the first description of mare follicular fluid proteome during the late follicle development stages. We identified several proteins from crude, depleted and enriched follicular fluid. Our results demonstrate that the enrichment method, combined with 2D-PAGE and mass spectrometry, can be successfully used to visualize and further identify the low-abundance proteins in the follicular fluid. PMID:21923925

  10. Proteomic analysis of mare follicular fluid during late follicle development.

    PubMed

    Fahiminiya, Somayyeh; Labas, Valérie; Roche, Stéphane; Dacheux, Jean-Louis; Gérard, Nadine

    2011-09-17

    Follicular fluid accumulates into the antrum of follicle from the early stage of follicle development. Studies on its components may contribute to a better understanding of the mechanisms underlying follicular development and oocyte quality. With this objective, we performed a proteomic analysis of mare follicular fluid. First, we hypothesized that proteins in follicular fluid may differ from those in the serum, and also may change during follicle development. Second, we used four different approaches of Immunodepletion and one enrichment method, in order to overcome the masking effect of high-abundance proteins present in the follicular fluid, and to identify those present in lower abundance. Finally, we compared our results with previous studies performed in mono-ovulant (human) and poly-ovulant (porcine and canine) species in an attempt to identify common and/or species-specific proteins. Follicular fluid samples were collected from ovaries at three different stages of follicle development (early dominant, late dominant and preovulatory). Blood samples were also collected at each time. The proteomic analysis was carried out on crude, depleted and enriched follicular fluid by 2D-PAGE, 1D-PAGE and mass spectrometry. Total of 459 protein spots were visualized by 2D-PAGE of crude mare follicular fluid, with no difference among the three physiological stages. Thirty proteins were observed as differentially expressed between serum and follicular fluid. Enrichment method was found to be the most powerful method for detection and identification of low-abundance proteins from follicular fluid. Actually, we were able to identify 18 proteins in the crude follicular fluid, and as many as 113 in the enriched follicular fluid. Inhibins and a few other proteins involved in reproduction could only be identified after enrichment of follicular fluid, demonstrating the power of the method used. The comparison of proteins found in mare follicular fluid with proteins previously identified in human, porcine and canine follicular fluids, led to the identification of 12 common proteins and of several species-specific proteins. This study provides the first description of mare follicular fluid proteome during the late follicle development stages. We identified several proteins from crude, depleted and enriched follicular fluid. Our results demonstrate that the enrichment method, combined with 2D-PAGE and mass spectrometry, can be successfully used to visualize and further identify the low-abundance proteins in the follicular fluid.

  11. Proteomic Characterization of Dermal Interstitial Fluid Extracted Using a Novel Microneedle-Assisted Technique.

    PubMed

    Tran, Bao Quoc; Miller, Philip R; Taylor, Robert M; Boyd, Gabrielle; Mach, Phillip M; Rosenzweig, C Nicole; Baca, Justin T; Polsky, Ronen; Glaros, Trevor

    2018-01-05

    As wearable fitness devices have gained commercial acceptance, interest in real-time monitoring of an individual's physiological status using noninvasive techniques has grown. Microneedles have been proposed as a minimally invasive technique for sampling the dermal interstitial fluid (ISF) for clinical monitoring and diagnosis, but little is known about its composition. In this study, a novel microneedle array was used to collect dermal ISF from three healthy human donors and compared with matching serum and plasma samples. Using a shotgun quantitative proteomic approach, 407 proteins were quantified with at least one unique peptide, and of those, 135 proteins were differently expressed at least 2-fold. Collectively, these proteins tended to originate from the cytoplasm, membrane bound vesicles, and extracellular vesicular exosomes. Proteomic analysis confirmed previously published work that indicates that ISF is highly similar to both plasma and serum. In this study, less than one percent of proteins were uniquely identified in ISF. Taken together, ISF could serve as a minimally invasive alternative for blood-derived fluids with potential for real-time monitoring applications.

  12. Time required to achieve maximum concentration of amikacin in synovial fluid of the distal interphalangeal joint after intravenous regional limb perfusion in horses.

    PubMed

    Kilcoyne, Isabelle; Nieto, Jorge E; Knych, Heather K; Dechant, Julie E

    2018-03-01

    OBJECTIVE To determine the maximum concentration (Cmax) of amikacin and time to Cmax (Tmax) in the distal interphalangeal (DIP) joint in horses after IV regional limb perfusion (IVRLP) by use of the cephalic vein. ANIMALS 9 adult horses. PROCEDURES Horses were sedated and restrained in a standing position and then subjected to IVRLP (2 g of amikacin sulfate diluted to 60 mL with saline [0.9% NaCl] solution) by use of the cephalic vein. A pneumatic tourniquet was placed 10 cm proximal to the accessory carpal bone. Perfusate was instilled with a peristaltic pump over a 3-minute period. Synovial fluid was collected from the DIP joint 5, 10, 15, 20, 25, and 30 minutes after IVRLP; the tourniquet was removed after the 20-minute sample was collected. Blood samples were collected from the jugular vein 5, 10, 15, 19, 21, 25, and 30 minutes after IVRLP. Amikacin was quantified with a fluorescence polarization immunoassay. Median Cmax of amikacin and Tmax in the DIP joint were determined. RESULTS 2 horses were excluded because an insufficient volume of synovial fluid was collected. Median Cmax for the DIP joint was 600 μg/mL (range, 37 to 2,420 μg/mL). Median Tmax for the DIP joint was 15 minutes. CONCLUSIONS AND CLINICAL RELEVANCE Tmax of amikacin was 15 minutes after IVRLP in horses and Cmax did not increase > 15 minutes after IVRLP despite maintenance of the tourniquet. Application of a tourniquet for 15 minutes should be sufficient for completion of IVRLP when attempting to achieve an adequate concentration of amikacin in the synovial fluid of the DIP joint.

  13. A fluid collection system for dermal wounds in clinical investigations

    PubMed Central

    Klopfer, Michael; Li, G.-P.; Widgerow, Alan; Bachman, Mark

    2016-01-01

    In this work, we demonstrate the use of a thin, self adherent, and clinically durable patch device that can collect fluid from a wound site for analysis. This device is manufactured from laminated silicone layers using a novel all-silicone double-molding process. In vitro studies for flow and delivery were followed by a clinical demonstration for exudate collection efficiency from a clinically presented partial thickness burn. The demonstrated utility of this device lends itself for use as a research implement used to clinically sample wound exudate for analysis. This device can serve as a platform for future integration of wearable technology into wound monitoring and care. The demonstrated fabrication method can be used for devices requiring thin membrane construction. PMID:27051470

  14. Etiology of parapneumonic effusion and pleural empyema in children. The role of conventional and molecular microbiological tests.

    PubMed

    Krenke, Katarzyna; Sadowy, Ewa; Podsiadły, Edyta; Hryniewicz, Waleria; Demkow, Urszula; Kulus, Marek

    2016-07-01

    An increasing incidence of parapneumonic effusion and pleural empyema (PPE/PE) has been reported in recent studies. As only few data on etiology of PPE/PE in Central Europe have been reported, we undertook a study on the etiology of PPE/PE in children, using both standard culture and molecular techniques. This prospective study was conducted between June 2011 and December 2013. Consecutive children with PPE/PE complicating community acquired pneumonia, who required diagnostic/therapeutic thoracentesis were included. Blood and pleural fluid samples for microbiological cultures were collected. Molecular methods were applied to identify Streptococcus pneumonia, Haemophilus influenzae, Staphylococcus aureus, Streptococcus pyogenes, Mycoplasma pneumoniae, Chlamydophila pneumoniae, and respiratory viruses in pleural fluid. The study group included 64 children, median age 4 (1-15). Seven of 64 (10.9%) blood cultures and 11 of 64 (17.2%) pleural fluid cultures revealed bacterial growth. The most common bacteria detected was S. pneumoniae (13 blood and pleural fluid samples from 11/64 (17.2%) children). DNA sequences of typical bacteria were found in 29/64 (45.3%) pleural fluid samples. S. pneumoniae was identified in 90% of these samples. The most common serotypes were: serotype 6B in 9/26 (36.6%), 19A in 6/26 (23%), serotype 3 in 3/26 (11.5%), 6A and 23F (both in 2/26 i.e. 7.7%) patients. Molecular methods identified atypical bacteria in 8/58 (13.8%) and respiratory viruses in 12/58 (20.7%) pleural fluid samples. S. pneumoniae, in particular serotype 6B and 19A, is the most common etiologic agent of PPE/PE in Polish children. The use of PCR significantly improves pathogen identification in pleural fluid. Copyright © 2016 Elsevier Ltd. All rights reserved.

  15. EFFECT OF MENTAL EXERCISE ON PAROTID FLOW RATE IN THE HUMAN.

    DTIC Science & Technology

    Three experiments were carried out in which paired parotid fluid samples were collected from 225 healthy young adults in an effort to ascertain the...providing the initial sample. There was no indication in any of the 3 experiments that mental concentration produced a significant effect on the rate of parotid flow. (Author)

  16. Role of intraocular Leptospira infections in the pathogenesis of Equine Recurrent Uveitis in the Southern United States

    USDA-ARS?s Scientific Manuscript database

    To investigate the role of intraocular leptospiral infections in horses with Equine Recurrent Uveitis (ERU) in the southern United States, blood and ocular fluid samples were collected from horses with a history and ocular findings consistent with ERU. Samples were also obtained from control horses ...

  17. Eukaryote-Made Thermostable DNA Polymerase Enables Rapid PCR-Based Detection of Mycoplasma, Ureaplasma and Other Bacteria in the Amniotic Fluid of Preterm Labor Cases.

    PubMed

    Ueno, Tomohiro; Niimi, Hideki; Yoneda, Noriko; Yoneda, Satoshi; Mori, Masashi; Tabata, Homare; Minami, Hiroshi; Saito, Shigeru; Kitajima, Isao

    2015-01-01

    Intra-amniotic infection has long been recognized as the leading cause of preterm delivery. Microbial culture is the gold standard for the detection of intra-amniotic infection, but several days are required, and many bacterial species in the amniotic fluid are difficult to cultivate. We developed a novel nested-PCR-based assay for detecting Mycoplasma, Ureaplasma, other bacteria and fungi in amniotic fluid samples within three hours of sample collection. To detect prokaryotes, eukaryote-made thermostable DNA polymerase, which is free from bacterial DNA contamination, is used in combination with bacterial universal primers. In contrast, to detect eukaryotes, conventional bacterially-made thermostable DNA polymerase is used in combination with fungal universal primers. To assess the validity of the PCR assay, we compared the PCR and conventional culture results using 300 amniotic fluid samples. Based on the detection level (positive and negative), 93.3% (280/300) of Mycoplasma, 94.3% (283/300) of Ureaplasma, 89.3% (268/300) of other bacteria and 99.7% (299/300) of fungi matched the culture results. Meanwhile, concerning the detection of bacteria other than Mycoplasma and Ureaplasma, 228 samples were negative according to the PCR method, 98.2% (224/228) of which were also negative based on the culture method. Employing the devised primer sets, mixed amniotic fluid infections of Mycoplasma, Ureaplasma and/or other bacteria could be clearly distinguished. In addition, we also attempted to compare the relative abundance in 28 amniotic fluid samples with mixed infection, and judged dominance by comparing the Ct values of quantitative real-time PCR. We developed a novel PCR assay for the rapid detection of Mycoplasma, Ureaplasma, other bacteria and fungi in amniotic fluid samples. This assay can also be applied to accurately diagnose the absence of bacteria in samples. We believe that this assay will positively contribute to the treatment of intra-amniotic infection and the prevention of preterm delivery.

  18. Eukaryote-Made Thermostable DNA Polymerase Enables Rapid PCR-Based Detection of Mycoplasma, Ureaplasma and Other Bacteria in the Amniotic Fluid of Preterm Labor Cases

    PubMed Central

    Yoneda, Noriko; Yoneda, Satoshi; Mori, Masashi; Tabata, Homare; Minami, Hiroshi; Saito, Shigeru; Kitajima, Isao

    2015-01-01

    Background Intra-amniotic infection has long been recognized as the leading cause of preterm delivery. Microbial culture is the gold standard for the detection of intra-amniotic infection, but several days are required, and many bacterial species in the amniotic fluid are difficult to cultivate. Methods We developed a novel nested-PCR-based assay for detecting Mycoplasma, Ureaplasma, other bacteria and fungi in amniotic fluid samples within three hours of sample collection. To detect prokaryotes, eukaryote-made thermostable DNA polymerase, which is free from bacterial DNA contamination, is used in combination with bacterial universal primers. In contrast, to detect eukaryotes, conventional bacterially-made thermostable DNA polymerase is used in combination with fungal universal primers. To assess the validity of the PCR assay, we compared the PCR and conventional culture results using 300 amniotic fluid samples. Results Based on the detection level (positive and negative), 93.3% (280/300) of Mycoplasma, 94.3% (283/300) of Ureaplasma, 89.3% (268/300) of other bacteria and 99.7% (299/300) of fungi matched the culture results. Meanwhile, concerning the detection of bacteria other than Mycoplasma and Ureaplasma, 228 samples were negative according to the PCR method, 98.2% (224/228) of which were also negative based on the culture method. Employing the devised primer sets, mixed amniotic fluid infections of Mycoplasma, Ureaplasma and/or other bacteria could be clearly distinguished. In addition, we also attempted to compare the relative abundance in 28 amniotic fluid samples with mixed infection, and judged dominance by comparing the Ct values of quantitative real-time PCR. Conclusions We developed a novel PCR assay for the rapid detection of Mycoplasma, Ureaplasma, other bacteria and fungi in amniotic fluid samples. This assay can also be applied to accurately diagnose the absence of bacteria in samples. We believe that this assay will positively contribute to the treatment of intra-amniotic infection and the prevention of preterm delivery. PMID:26042418

  19. Method and Apparatus for the Collection Storage and Real Time Analysis of Blood and Other Bodily Fluids

    NASA Technical Reports Server (NTRS)

    Whitson, Peggy A. (Inventor); Clift, Vaughan L. (Inventor)

    1997-01-01

    The present invention provides an apparatus for separating a relatively large volume of blood into cellular and acellular fractions without the need for centrifugation. The apparatus comprises a housing divided by a fibrous filter into a blood sample collection chamber having a volume of at least about 1 milliliter and a serum sample collection chamber. The fibrous filter has a pore size of less than about 3 microns, and is coated with a mixture of mannitol and plasma fraction protein (or an animal or vegetable equivalent thereof). The coating causes the cellular fraction to be trapped by the small pores, leaving the cellular fraction intact on the fibrous filter while the acellular fraction passes through the filter for collection in unaltered form from the serum sample collection chamber.

  20. Development of a novel method for amniotic fluid stem cell storage.

    PubMed

    Zavatti, Manuela; Beretti, Francesca; Casciaro, Francesca; Comitini, Giuseppina; Franchi, Fabrizia; Barbieri, Veronica; Bertoni, Laura; De Pol, Anto; La Sala, Giovanni B; Maraldi, Tullia

    2017-08-01

    Current procedures for collection of human amniotic fluid stem cells (hAFSCs) indicate that cells cultured in a flask for 2 weeks can then be used for research. However, hAFSCs can be retrieved directly from a small amount of amniotic fluid that can be obtained at the time of diagnostic amniocentesis. The aim of this study was to determine whether direct freezing of amniotic fluid cells is able to maintain or improve the potential of a sub-population of stem cells. We compared the potential of the hAFSCs regarding timing of freezing, cells obtained directly from amniotic fluid aspiration (D samples) and cells cultured in a flask before freezing (C samples). Colony-forming-unit ability, proliferation, morphology, stemness-related marker expression, senescence, apoptosis and differentiation potential of C and D samples were compared. hAFSCs isolated from D samples expressed mesenchymal stem cells markers until later passages, had a good proliferation rate and exhibited differentiation capacity similar to hAFSCs of C samples. Interestingly, direct freezing induced a higher concentration of cells positive for pluripotency stem cell markers, without teratoma formation in vivo. This study suggests that minimal processing may be adequate for the banking of amniotic fluid cells, avoiding in vitro passages before the storage and exposure to high oxygen concentration, which affect stem cell properties. This technique might be a cost-effective and reasonable approach to the process of Good Manufacturing Process accreditation for stem-cell banks. Copyright © 2017 International Society for Cellular Therapy. Published by Elsevier Inc. All rights reserved.

  1. IGF-I and NEFA concentrations in fetal fluids of term pregnancy dogs.

    PubMed

    Meloni, Tea; Comin, Antonella; Rota, Alessandro; Peric, Tanja; Contri, Alberto; Veronesi, Maria Cristina

    2014-06-01

    Insulin-like growth factor-I (IGF-I) and non-esterified fatty acids (NEFA) play an essential role in fetal growth and development. To date, fetal fluids IGF-I and NEFA levels at term canine pregnancy are unknown and could be related to the neonatal development and breed size. For these reasons, the aims of the present study were as follows: (1) to evaluate IGF-I and NEFA concentrations in fetal fluids collected from normally developed and viable newborn puppies born at term of normal pregnancies; (2) to assess possible differences between IGF-I and NEFA levels in amniotic compared with allantoic fluid; (3) to detect possible relationship between breed body size and IGF-I and NEFA amniotic and allantoic concentrations; (4) to evaluate possible differences in IGF-I fetal fluids levels between male and female puppies; and (5) to assess possible correlations between the two hormones in each type of fluid. The study enrolled 25 pure breed bitches submitted to elective Cesarean section at term because of the high risk of dystocia or previous troubles at parturition. At surgery, amniotic and allantoic fluids were collected and assayed for IGF-I and NEFA. IGF-I and NEFA amounts in both amniotic and allantoic fluids of different breed size bitches (small: ≤10 kg; medium: 11-25 kg; large: 26-40 kg) were detected, as well as the effect of gender on IGF-I levels. On a total of 73 amniotic and 76 allantoic samples collected by normal, viable, and mature newborns, the mean IGF-I concentration was significantly higher in amniotic than in allantoic fluid in all three groups, but the amniotic IGF-I levels were significantly lower in small and medium size bitches when compared with large ones. No significant differences were found in allantoic IGF-I concentrations among size groups. A significant effect of the puppy gender on IGF-I content in both fetal fluids was not reported. Regarding NEFA, in all the three groups, the mean NEFA concentration did not significantly differ between amnion and allantois, but in both fetal fluids, higher NEFA levels were detected in samples belonging to small breeds when compared with medium and large. These data strongly indicated that, also in the dog, a relation between fetal fluids IGF-I and NEFA concentrations and breed size exists. Further research is needed to elucidate the possible role of IGF-I and NEFA in the pathologic conditions related to canine fetal growth. Copyright © 2014 Elsevier Inc. All rights reserved.

  2. The U-tube: A novel system for acquiring borehole fluid samples from a deep geologic CO2 sequestration experiment

    USGS Publications Warehouse

    Freifeild, Barry M.; Trautz, Robert C.; Kharaka, Yousif K.; Phelps, Tommy J.; Myer, Larry R.; Hovorka, Susan D.; Collins, Daniel J.

    2005-01-01

    A novel system has been deployed to obtain geochemical samples of water and gas, at in situ pressure, during a geologic CO2 sequestration experiment conducted in the Frio brine aquifer in Liberty County, Texas. Project goals required high-frequency recovery of representative and uncontaminated aliquots of a rapidly changing two-phase fluid (supercritical CO2 and brine) fluid from 1.5 km depth. The data sets collected, using both the liquid and gas portions of the downhole samples, provide insights into the coupled hydrogeochemical issues affecting CO2sequestration in brine-filled formations. While the basic premise underlying the U-tube sampler is not new, the system is unique because careful consideration was given to the processing of the recovered two-phase fluids. In particular, strain gauges mounted beneath the high-pressure surface sample cylinders measured the ratio of recovered brine to supercritical CO2. A quadrupole mass spectrometer provided real-time gas analysis for perfluorocarbon and noble gas tracers that were injected along with the CO2. The U-tube successfully acquired frequent samples, facilitating accurate delineation of the arrival of the CO2 plume, and on-site analysis revealed rapid changes in geochemical conditions.

  3. The U-tube: A novel system for acquiring borehole fluid samples from a deep geologic CO2 sequestration experiment

    USGS Publications Warehouse

    Freifeild, Barry M.; Trautz, Robert C.; Kharaka, Yousif K.; Phelps, Tommy J.; Myer, Larry R.; Hovorka, Susan D.; Collins, Daniel J.

    2005-01-01

    A novel system has been deployed to obtain geochemical samples of water and gas, at in situ pressure, during a geologic CO2 sequestration experiment conducted in the Frio brine aquifer in Liberty County, Texas. Project goals required high-frequency recovery of representative and uncontaminated aliquots of a rapidly changing two-phase fluid (supercritical CO2 and brine) fluid from 1.5 km depth. The data sets collected, using both the liquid and gas portions of the downhole samples, provide insights into the coupled hydrogeochemical issues affecting CO2 sequestration in brine-filled formations. While the basic premise underlying the U-tube sampler is not new, the system is unique because careful consideration was given to the processing of the recovered two-phase fluids. In particular, strain gauges mounted beneath the high-pressure surface sample cylinders measured the ratio of recovered brine to supercritical CO2. A quadrupole mass spectrometer provided real-time gas analysis for perfluorocarbon and noble gas tracers that were injected along with the CO2. The U-tube successfully acquired frequent samples, facilitating accurate delineation of the arrival of the CO2 plume, and on-site analysis revealed rapid changes in geochemical conditions.

  4. The U-tube: A novel system for acquiring borehole fluid samples from a deep geologic CO2 sequestration experiment

    NASA Astrophysics Data System (ADS)

    Freifeld, Barry M.; Trautz, Robert C.; Kharaka, Yousif K.; Phelps, Tommy J.; Myer, Larry R.; Hovorka, Susan D.; Collins, Daniel J.

    2005-10-01

    A novel system has been deployed to obtain geochemical samples of water and gas, at in situ pressure, during a geologic CO2 sequestration experiment conducted in the Frio brine aquifer in Liberty County, Texas. Project goals required high-frequency recovery of representative and uncontaminated aliquots of a rapidly changing two-phase fluid (supercritical CO2 and brine) fluid from 1.5 km depth. The data sets collected, using both the liquid and gas portions of the downhole samples, provide insights into the coupled hydrogeochemical issues affecting CO2 sequestration in brine-filled formations. While the basic premise underlying the U-tube sampler is not new, the system is unique because careful consideration was given to the processing of the recovered two-phase fluids. In particular, strain gauges mounted beneath the high-pressure surface sample cylinders measured the ratio of recovered brine to supercritical CO2. A quadrupole mass spectrometer provided real-time gas analysis for perfluorocarbon and noble gas tracers that were injected along with the CO2. The U-tube successfully acquired frequent samples, facilitating accurate delineation of the arrival of the CO2 plume, and on-site analysis revealed rapid changes in geochemical conditions.

  5. Alpha-fetoprotein as a tool to distinguish amniotic fluid from urine, vaginal discharge, and semen.

    PubMed

    Mor, Amir; Tal, Reshef; Haberman, Shoshana; McCalla, Sandra; Irani, Mohamad; Perlman, Jaqueline; Seifer, David B; Minkoff, Howard

    2015-02-01

    To estimate whether alpha-fetoprotein (AFP) can be used to distinguish amniotic fluid absorbed in sanitary pads from other similarly absorbed substances (semen, urine, and normal vaginal discharge). A prospective cohort study. Urine and amniotic fluid specimens were collected from 52 pregnant women admitted for labor. Semen specimens were collected from 17 men undergoing infertility evaluation. Alpha-fetoprotein concentrations were measured directly from urine, amniotic fluid, and semen and from pads instilled with samples from these specimens. Alpha-fetoprotein concentrations were also measured from pads absorbed with normal vaginal discharge collected from 27 pregnant women. Alpha-fetoprotein levels in amniotic fluid (245.38 ± 21.03 ng/mL, n = 52) were significantly higher than those measured in maternal urine (0.84 ± 0.17 ng/mL, n = 52, P < .001), or semen (1.52 ± 0.35 ng/mL, n = 17, P < .001). The same trend was seen when AFP was extracted from pads: amniotic fluid levels (19.44 ± 1.98 ng/mL, n=52) were significantly higher than those of urine (undetectable, n=52), semen (undetectable, n = 17), or normal vaginal discharge (0.53 ± 0.16 ng/mL, n = 27, P < .001). Receiver operator characteristic curve analysis demonstrated 96.2% sensitivity and 100% specificity for distinguishing the presence of amniotic fluid from normal vaginal discharge on sanitary pads (cutoff 3.88 ng/mL, area under the curve 0.99). When the diagnosis of rupture of membranes is in doubt, AFP levels can assist in differentiating amniotic fluid from other bodily fluids. A method that utilizes sanitary pads and an assay for AFP quantification may be an accurate and convenient way to confirm the diagnosis of rupture of membranes.

  6. Prevalence and relevance of antibodies to type-I and -II collagen in synovial fluid of dogs with cranial cruciate ligament damage.

    PubMed

    de Rooster, H; Cox, E; van Bree, H

    2000-11-01

    To measure and compare synovial fluid antibody titers to type-I and -II collagen in stifle joints with instability caused by complete or partial cranial cruciate ligament (CCL) rupture and joints with osteoarthrosis secondary to other pathologic changes in dogs. 82 dogs with diseased stifle joints. Synovial fluid samples were collected from 7 dogs with clinically normal stifles (control group) and 82 dogs with diseased joints (50 stifle joints with complete rupture of the CCL, 20 with partial damage of the CCL, and 12 joints with radiographic signs of osteoarthritis secondary to other arthropathies). Synovial fluid samples were tested for autoantibodies to type-I and -II collagen by an ELISA. In dogs with complete and partial CCL rupture, synovial fluid antibody titers to type-I and -II collagen were significantly increased, compared with control dogs. Forty-eight percent (24/50) of samples from dogs with complete CCL rupture and 35% (7/20) of samples from dogs with partial CCL rupture had antibody titers to type-I collagen that were greater than the mean plus 2 standard deviations of the control group titers. Synovial fluid antibody titers to type-II collagen were high in 40% of the dogs with partial or (8/20) complete (20/50) CCL rupture. Dogs with osteoarthrosis secondary to other pathologic changes had significantly increased synovial fluid antibodies to type-I and -II collagen, compared with control dogs. Increases in autoantibodies to collagen in synovial fluid are not specific for the type of joint disorder. It is unlikely that the anticollagen antibodies play an active role in the initiation of weakening of the CCL.

  7. Results of investigation at the Miravalles geothermal field, Costa Rica. Resultados de las investigaciones en el campo geotermico de Miravalles, Costa Rica; Parte 2, Muestreo de fluidos pozo abajo

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Grigsby, C.O.; Goff, F.; Trujillo, P.E. Jr.

    Samples of the geothermal fluids in the Miravalles, Costa Rica, geothermal system were collected from production wellbores using downhole fluid samplers, from flowing wellheads using miniseparators, and from hot springs that discharge in the area. The reservoir fluid at Miravalles is a neutral-chloride-type water, but fumaroles and acid-sulfate springs are present within the main thermal area, and there are bicarbonate-rich hot springs that are clearly related to the neutral-chloride reservoir fluids. Dissolved gases are primarily a mixture of CO{sub 2} with air, but samples collected in the fumarolic areas also contain H{sub 2}S. Water-stable isotope analyses suggest local meteoric recharge,more » and the reservoir fluid shows oxygen isotopic shifts of about 2.5% due to high-temperature oxygen exchange between water and rock. Chemical geothermometer temperatures are consistent with the measured downhole temperature of 220{degrees} to 255{degrees}C. This pattern of neutral-chloride reservoir fluids with acid-sulfate springs near the source region and bicarbonate-rich chloride hot springs at the periphery of the system suggests a lateral outflow type of hydrothermal system. In addition to the geochemical evidence, temperature profiles from several of the wells show temperature reversals that are characteristic of lateral outflow plumes. We find no evidence for the underlying, higher temperature (300{degrees}C) system, which has been suggested by other investigators. 24 refs., 14 figs., 6 tabs.« less

  8. Monitoring CO2 emissions in tree kill areas near the resurgent dome at Long Valley Caldera, California

    USGS Publications Warehouse

    Bergfeld, D.; Evans, William C.

    2011-01-01

    We report results of yearly measurements of the diffuse CO2 flux and shallow soil temperatures collected since 2006 across two sets of tree-kill areas at Long Valley Caldera, California. These data provide background information about CO2 discharge during a period with moderate seismicity, but little to no deformation. The tree kills are located at long-recognized areas of weak thermal fluid upflow, but have expanded in recent years, possibly in response to geothermal fluid production at Casa Diablo. The amount of CO2 discharged from the older kill area at Basalt Canyon is fairly constant and is around 3-5 tonnes of CO2 per day from an area of about 15,000 m2. The presence of isobutane in gas samples from sites in and around Basalt Canyon suggests that geothermal fluid production directly effects fluid upflow in the region close to the power plant. The average fluxes at Shady Rest are lower than average fluxes at Basalt Canyon, but the area affected by fluid upflow is larger. Total CO2 discharged from the central portion of the kill area at Shady Rest has been variable, ranging from 6 to11 tonnes per day across 61,000 m2. Gas collected at Shady Rest contains no detectable isobutane to link emissions chemically to geothermal fluid production, but two samples from 2009-10 have detectable H2S and suggest an increasing geothermal character of emitted gas. The appearance of this gas at the surface may signal increased drawdown of water levels near the geothermal productions wells.

  9. Multi-elemental analysis of aqueous geological samples by inductively coupled plasma-optical emission spectrometry

    USGS Publications Warehouse

    Todorov, Todor I.; Wolf, Ruth E.; Adams, Monique

    2014-01-01

    Typically, 27 major, minor, and trace elements are determined in natural waters, acid mine drainage, extraction fluids, and leachates of geological and environmental samples by inductively coupled plasma-optical emission spectrometry (ICP-OES). At the discretion of the analyst, additional elements may be determined after suitable method modifications and performance data are established. Samples are preserved in 1–2 percent nitric acid (HNO3) at sample collection or as soon as possible after collection. The aqueous samples are aspirated into the ICP-OES discharge, where the elemental emission signals are measured simultaneously for 27 elements. Calibration is performed with a series of matrix-matched, multi-element solution standards.

  10. Using Fluid Inclusions to Bring Phase Diagrams to Life in a Guided Inquiry Instructional Setting

    NASA Astrophysics Data System (ADS)

    Farver, J. R.; Onasch, C.

    2011-12-01

    A fundamental concept in mineralogy, petrology, and geochemistry is the generation and interpretation of phase diagrams for various systems. We have developed an exercise to strengthen student's familiarity with and confidence in employing phase diagrams by using fluid inclusions. The activity follows the 5Es (Engagement, Exploration, Explanation, Extension, Evaluation) guided inquiry instructional model in order to best facilitate student learning. The exercise follows an activity adapted from Brady (1992) wherein students collect data to generate the phase diagram for the Ice-Water-NaCl system. The engagement activity involves using a USGS-type fluid inclusion heating-cooling stage with a camera and projection system. We typically employ either a doubly-polished quartz sample or a cleaved section of fluorite and select a typical two phase (L + V) aqueous inclusion. Students first observe the inclusion at room temperature and pressure and are asked to predict what would happen if the sample is heated. Students then watch as the sample is heated to its homogenization temperature (Th) and are asked to explain what they see. The sample is then cooled until completely frozen and then slowly warmed until the first ice melting (at the eutectic, Te) and then until all ice melts (Tm). Again, students are asked to explain what they see and, if necessary, they are guided to remember the earlier phase diagram activity. The process is then repeated while students follow along the appropriate phase diagrams. In this fashion, students literally see the changes in phases present and their relative abundances as they move through the phase diagram. The engagement activity generates student interest in the exercise to insure minds-on as well as hands-on exploration. The exploration activities involve students observing and describing a wide range of fluid inclusion types (e.g., CO2, daughter crystals, multiple inclusion trails, etc) and hands-on collection of Th and Tm data for a selected sample. Using a fluorite sample (Denton Mine) yields excellent results and a meaningful extension activity. Each student collects Th and Tm data that are then combined and class histograms are generated and interpreted. At this point, a general explanation of fluid inclusions is provided to bring together the student's observations and to assess their understanding. The extension activity involves using the Th, Te, and Tm data obtained for primary inclusions to constrain the true trapping temperature (Tt). The isochore is calculated and plotted on a P-T plot. Using the geothermal gradient for the sample locale, students calculate the hydrostatic and lithostatic gradients for the region and plot these on the P-T diagram in order to constrain the possible range in Tt. Finally, based upon the salinity and Tt range, students determine what ore fluid type is represented (MVT). The evaluation includes observation of participation, answers to questions posed during the engagement activity, and a written report that includes answers to refining and open-ended questions as well as a reflection on their learning. This activity strengthens student's understanding of phase diagrams while introducing them to the importance of fluids in the crust.

  11. Characterisation of lubricin in synovial fluid from horses with osteoarthritis.

    PubMed

    Svala, E; Jin, C; Rüetschi, U; Ekman, S; Lindahl, A; Karlsson, N G; Skiöldebrand, E

    2017-01-01

    The glycoprotein lubricin contributes to the boundary lubrication of the articular cartilage surface. The early events of osteoarthritis involve the superficial layer where lubricin is synthesised. To characterise the glycosylation profile of lubricin in synovial fluid from horses with osteoarthritis and study secretion and degradation of lubricin in an in vitro inflammation cartilage model. In vitro study. Synovial fluid samples collected from horses with joints with normal articular cartilage and structural osteoarthritic lesions; with and without osteochondral fragments, were analysed for the lubricin glycosylation profiles. Articular cartilage explants were stimulated with or without interleukin-1β for 25 days. Media samples collected at 3-day intervals were analysed by quantitative proteomics, western blot and enzyme-linked immunosorbent assay. O-glycosylation profiles in synovial fluid revealed both Core 1 and 2 O-glycans, with Core 1 O-glycans predominating. Synovial fluid from normal joints (49.5 ± 1.9%) contained significantly lower amounts of monosialylated Core 1 O-glycans compared with joints with osteoarthritis (53.8 ± 7.8%, P = 0.03) or joints with osteochondral fragments (57.3 ± 8.8%, P = 0.001). Additionally, synovial fluid from normal joints (26.7 ± 6.7%) showed higher amounts of disialylated Core 1 O-glycan than from joints with osteochondral fragments (21.2 ± 4.9%, P = 0.03). A C-terminal proteolytic cleavage site in lubricin was found in synovial fluid from normal and osteochondral fragment joints and in media from interleukin-1β stimulated and unstimulated articular cartilage explants. This is the first demonstration of a change in the glycosylation profile of lubricin in synovial fluid from diseased equine joints compared with that from normal joints. We demonstrate an identical proteolytic cleavage site of lubricin both in vitro and in vivo. The reduced sialation of lubricin in synovial fluid from diseased joints may affect the boundary lubricating ability of the superficial layer of articular cartilage and could be one of the early events in the progression of osteoarthritis. © 2015 EVJ Ltd.

  12. Simethicone residue remains inside gastrointestinal endoscopes despite reprocessing.

    PubMed

    Ofstead, Cori L; Wetzler, Harry P; Johnson, Ellen A; Heymann, Otis L; Maust, Thomas J; Shaw, Michael J

    2016-11-01

    During a study designed to assess endoscope reprocessing effectiveness, a borescope was used to examine lumens and ports. Cloudy, white, viscous fluid was observed inside fully reprocessed gastroscopes and colonoscopes. This fluid resembled simethicone, which is commonly administered to reduce foam and bubbles that impede visualization during gastrointestinal endoscopy. This article describes methods used to determine whether the observed fluid contained simethicone. Photographs of residual fluid were taken using a borescope. Sterile cotton-tipped swabs were used to collect samples of fluid observed in 3 endoscope ports. Samples were evaluated using Fourier transform infrared spectroscopy (FTIR)-attenuated total reflection analysis. Residual fluid was observed inside 19 of 20 endoscopes. Fluid photographed in 8 endoscopes resembled simethicone solutions. FTIR analysis confirmed the presence of simethicone in 2 endoscopes. Fluid containing simethicone remained inside endoscopes despite reprocessing. Simethicone is an inert, hydrophobic substance that may reduce reprocessing effectiveness. Simethicone solutions commonly contain sugars and thickeners, which may contribute to microbial growth and biofilm development. Studies are needed to assess the prevalence of residual moisture and simethicone in endoscopes and determine the impact on reprocessing effectiveness. We recommend minimizing the use of simethicone pending further research into its safety. Copyright © 2016 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  13. High-performance liquid chromatographic determination of histamine in biological samples: the cerebrospinal fluid challenge--a review.

    PubMed

    Wang, Zhaopin; Wu, Juanli; Wu, Shihua; Bao, Aimin

    2013-04-24

    Histamine, a neurotransmitter crucially involved in a number of basic physiological functions, undergoes changes in neuropsychiatric disorders. Detection of histamine in biological samples such as cerebrospinal fluid (CSF) is thus of clinical importance. The most commonly used method for measuring histamine levels is high performance liquid chromatography (HPLC). However, factors such as very low levels of histamine, the even lower CSF-histamine and CSF-histamine metabolite levels, especially in certain neuropsychiatric diseases, rapid formation of histamine metabolites, and other confounding elements during sample collection, make analysis of CSF-histamine and CSF-histamine metabolites a challenging task. Nonetheless, this challenge can be met, not only with respect to HPLC separation column, derivative reagent, and detector, but also in terms of optimizing the CSF sample collection. This review aims to provide a general insight into the quantitative analyses of histamine in biological samples, with an emphasis on HPLC instruments, methods, and hyphenated techniques, with the aim of promoting the development of an optimal and practical protocol for the determination of CSF-histamine and/or CSF-histamine metabolites. Copyright © 2013 Elsevier B.V. All rights reserved.

  14. Microbial diversity within Juan de Fuca ridge basement fluids sampled from oceanic borehole observatories

    NASA Astrophysics Data System (ADS)

    Jungbluth, S.; Bowers, R.; Lin, H.; Hsieh, C.; Cowen, J. P.; Rappé, M.

    2012-12-01

    Three generations of sampling and instrumentation platforms known as Circulation Obviation Retrofit Kit (CORK) observatories affixed to Ocean Drilling Program (ODP) and Integrated Ocean Drilling Program (IODP) boreholes are providing unrivaled access to fluids originating from 1.2-3.5 million-years (Myr) old basaltic crust of the eastern flank of the Juan de Fuca ridge. Borehole fluid samples obtained via a custom seafloor fluid pumping and sampling system coupled to CORK continuous fluid delivery lines are yielding critical insights into the biogeochemistry and nature of microbial life inhabiting the sediment-covered basement environment. Direct microscopic enumeration revealed microbial cell abundances that are 2-41% of overlying bottom seawater. Snapshots of basement fluid microbial diversity and community structure have been obtained through small subunit ribosomal RNA (SSU rRNA) gene cloning and sequencing from five boreholes that access a range of basement ages and temperatures at the sediment-basement interface. SSU rRNA gene clones were derived from four different CORK installations (1026B, 1301A, 1362A, and 1362B) accessing relatively warmer (65°C) and older (3.5 Myr) ridge flank, and one location (1025C) accessing relatively cooler (39°C) and younger (1.2 Myr) ridge flank, revealing that warmer basement fluids had higher microbial diversity. A sampling time-series collected from borehole 1301A has revealed a microbial community that is temporally variable, with the dominant lineages changing between years. Each of the five boreholes sampled contained a unique microbial assemblage, however, common members are found from both cultivated and uncultivated lineages within the archaeal and bacterial domains, including meso- and thermophilic microbial lineages involved with sulfur cycling (e.g Thiomicrospira, Sulfurimonas, Desulfocapsa, Desulfobulbus). In addition, borehole fluid environmental gene clones were also closely related to uncultivated lineages recovered from both terrestrial and marine hydrothermal systems (e.g. Candidatus Desulforudis, Candidate Phylum OP8) as well as globally distributed marine sediments (e.g. Miscellaneous Crenarchaeotic Group, JTB35). This analysis provides a framework for future research investigating the evolutionary and functional diversity, population genetics, and activity of the poorly understood habitat. These ongoing sampling expeditions greatly benefit from improvements to both CORK observatories and evolving sampling equipment including microbiologically-friendly materials and dependable access to pristine fluids from the ocean crust.

  15. Human papillomavirus infection is associated with decreased levels of GM-CSF in cervico-vaginal fluid of infected women.

    PubMed

    Comar, Manola; Monasta, Lorenzo; Zanotta, Nunzia; Vecchi Brumatti, Liza; Ricci, Giuseppe; Zauli, Giorgio

    2013-10-01

    Although human papillomavirus (HPV) is the most common sexually transmitted infection, there are very scant data about the influence of this virus on the in vitro fertilization outcome. To assess the presence of HPV in the cervico-vaginal fluid in relationship to the in vitro fertilization (IVF) outcome and to the concentration of selected cytokines, known to affect embryo implantation and gestation: granulocyte-macrophage colony stimulating factor (GM-CSF) and granulocyte colony stimulating factor (G-CSF). Cervico-vaginal samples were collected on the day of oocyte pick-up from 82 women. Vaginas were flushed with 50 mL of sterile water and 3 mL of fluid was collected. Twelve women (15%) were positive for HPV. Interestingly, among HPV(+) women live birth rate was about half of the rate in HPV(-) women, although the differences were not statistically significant due to the low number of cases. Cervico-vaginal samples of a sub-group of 29 (8 HPV(+) and 21 HPV(-)) women were analyzed for GM-CSF and G-CSF by ELISA. GM-CSF but not G-CSF was significantly lower in the cervico-vaginal fluid of HPV(+) than in HPV(-) women. Since GM-CSF plays an important role during pregnancy, the reduced levels of GM-CSF in the cervico-vaginal fluid of HPV(+) women might contribute to explain the reduced live birth rate observed in HPV(+) women. Copyright © 2013 Elsevier B.V. All rights reserved.

  16. Comparison of Proteins in Whole Blood and Dried Blood Spot Samples by LC/MS/MS

    NASA Astrophysics Data System (ADS)

    Chambers, Andrew G.; Percy, Andrew J.; Hardie, Darryl B.; Borchers, Christoph H.

    2013-09-01

    Dried blood spot (DBS) sampling methods are desirable for population-wide biomarker screening programs because of their ease of collection, transportation, and storage. Immunoassays are traditionally used to quantify endogenous proteins in these samples but require a separate assay for each protein. Recently, targeted mass spectrometry (MS) has been proposed for generating highly-multiplexed assays for biomarker proteins in DBS samples. In this work, we report the first comparison of proteins in whole blood and DBS samples using an untargeted MS approach. The average number of proteins identified in undepleted whole blood and DBS samples by liquid chromatography (LC)/MS/MS was 223 and 253, respectively. Protein identification repeatability was between 77 %-92 % within replicates and the majority of these repeated proteins (70 %) were observed in both sample formats. Proteins exclusively identified in the liquid or dried fluid spot format were unbiased based on their molecular weight, isoelectric point, aliphatic index, and grand average hydrophobicity. In addition, we extended this comparison to include proteins in matching plasma and serum samples with their dried fluid spot equivalents, dried plasma spot (DPS), and dried serum spot (DSS). This work begins to define the accessibility of endogenous proteins in dried fluid spot samples for analysis by MS and is useful in evaluating the scope of this new approach.

  17. A prospective evaluation of the contribution of ambient temperatures and transport times on infrared thermometry readings of intravenous fluids utilized in EMS patients.

    PubMed

    Joslin, Jeremy; Fisher, Andrew; Wojcik, Susan; Cooney, Derek R

    2014-01-01

    During cold weather months in much of the country, the temperatures in which prehospital care is delivered creates the potential for inadvertently cool intravenous fluids to be administered to patients during their transport and care by emergency medical services (EMS). There is some potential for patient harm from unintentional infusion of cool intravenous fluids. Prehospital providers in these cold weather environments are likely using fluids that are well below room temperature when prehospital intravenous fluid (IVF) warming techniques are not being employed. It was hypothesized that cold ambient temperatures during winter months in the study location would lead to the inadvertent infusion of cold intravenous fluids during prehospital patient care. Trained student research assistants obtained three sequential temperature measurements using an infrared thermometer in a convenience sample of intravenous fluid bags connected to patients arriving via EMS during two consecutive winter seasons (2011 to 2013) at our receiving hospital in Syracuse, New York. Intravenous fluids contained in anything other than a standard polyvinyl chloride bag were not measured and were not included in the study. Outdoor temperature was collected by referencing National Weather Service online data at the time of arrival. Official transport times from the scene to the emergency department (ED) and other demographic data was collected from the EMS provider or their patient care record at the time of EMS interaction. Twenty-three intravenous fluid bag temperatures were collected and analyzed. Outdoor temperature was significantly related to the temperature of the intravenous fluid being administered, b = 0.69, t(21) = 4.3, p < 0.001. Transport time did not predict the measured intravenous fluid temperatures, b = 0.12, t(20) = 0.55, p < 0.6. Use of unwarmed intravenous fluid in the prehospital environment during times of cold ambient temperatures can lead to the infusion of cool intravenous fluid and may result in harm to patients. Short transport times do not limit this risk. Emergency departments should not rely on EMS agencies' use of intravenous fluid warming techniques and should consider replacing EMS intravenous fluids upon ED arrival to ensure patient safety.

  18. Using oral fluids samples for indirect influenza A virus surveillance in farmed UK pigs.

    PubMed

    Gerber, Priscilla F; Dawson, Lorna; Strugnell, Ben; Burgess, Robert; Brown, Helen; Opriessnig, Tanja

    2017-02-01

    Influenza A virus (IAV) is economically important in pig production and has broad public health implications. In Europe, active IAV surveillance includes demonstration of antigen in nasal swabs and/or demonstration of antibodies in serum (SER) samples; however, collecting appropriate numbers of individual pig samples can be costly and labour-intensive. The objective of this study was to compare the probability of detecting IAV antibody positive populations using SER versus oral fluid (OF) samples. Paired pen samples, one OF and 5-14 SER samples, were collected cross-sectional or longitudinally. A commercial nucleoprotein (NP)-based blocking ELISA was used to test 244 OF and 1004 SER samples from 123 pens each containing 20-540 pigs located in 27 UK herds. Overall, the IAV antibody detection rate was higher in SER samples compared to OFs under the study conditions. Pig age had a significant effect on the probability of detecting positive pens. For 3-9-week-old pigs the probability of detecting IAV antibody positive samples in a pen with 95% confidence intervals was 40% (23-60) for OF and 61% (0.37-0.80) for SER ( P  =   0.04), for 10-14-week-old pigs it was 19% (8-40) for OF and 93% (0.71-0.99) for SER ( P  <   0.01), and for 18-20-week-old pigs it was 67% (41-85) for OF and 81% (0.63-0.91) for SER ( P  =   0.05). Collecting more than one OF sample in pens with more than 25 less than 18-week-old pigs should be further investigated in the future to elucidate the suitability of OF for IAV surveillance in herds with large pen sizes.

  19. Investigating a persistent odor at an aircraft seat manufacturer.

    PubMed

    Broadwater, Kendra; de Perio, Marie A; Roberts, Jennifer; Burton, Nancy C; Lemons, Angela R; Green, Brett J; Brueck, Scott E

    2016-10-01

    An aircraft seat manufacturing company requested a NIOSH health hazard evaluation to help identify a strong odor that had persisted throughout the facility for over a year. Employees reported experiencing health effects thought to be related to the odor. We collected and analyzed area air samples for volatile organic compounds, endotoxin, bacterial and fungal metagenome, and metalworking fluid aerosol. Bulk metalworking fluid samples were analyzed for endotoxin, bacterial and fungal metagenome, and viable bacteria and fungus. We also evaluated the building ventilation systems and water diversion systems. Employees underwent confidential medical interviews about work practices, medical history, and health concerns. Based on our analyses, the odor was likely 2-methoxy-3,5-dimethylpyrazine. This pyrazine was found in air samples across the facility and originated from bacteria in the metalworking fluid. We did not identify bacteria known to produce the compound but bacteria from the same Proteobacteria order were found as well as bacteria from orders known to produce other pyrazines. Chemical and biological contaminants and odors could have contributed to health symptoms reported by employees, but it is likely that the symptoms were caused by several factors. We provided several recommendations to eliminate the odor including washing and disinfecting the metalworking machines and metalworking fluid recycling equipment, discarding all used metalworking fluid, instituting a metalworking fluid maintenance program at the site, and physically isolating the metalworking department from other departments.

  20. Investigating a persistent odor at an aircraft seat manufacturer

    PubMed Central

    Broadwater, Kendra; de Perio, Marie A.; Roberts, Jennifer; Burton, Nancy C.; Lemons, Angela R.; Green, Brett J.; Brueck, Scott E.

    2017-01-01

    An aircraft seat manufacturing company requested a NIOSH health hazard evaluation to help identify a strong odor that had persisted throughout the facility for over a year. Employees reported experiencing health effects thought to be related to the odor. We collected and analyzed area air samples for volatile organic compounds, endotoxin, bacterial and fungal metagenome, and metalworking fluid aerosol. Bulk metalworking fluid samples were analyzed for endotoxin, bacterial and fungal metagenome, and viable bacteria and fungus. We also evaluated the building ventilation systems and water diversion systems. Employees underwent confidential medical interviews about work practices, medical history, and health concerns. Based on our analyses, the odor was likely 2-methoxy-3,5-dimethylpyrazine. This pyrazine was found in air samples across the facility and originated from bacteria in the metalworking fluid. We did not identify bacteria known to produce the compound but bacteria from the same Proteobacteria order were found as well as bacteria from orders known to produce other pyrazines. Chemical and biological contaminants and odors could have contributed to health symptoms reported by employees, but it is likely that the symptoms were caused by several factors. We provided several recommendations to eliminate the odor including washing and disinfecting the metalworking machines and metalworking fluid recycling equipment, discarding all used metal-working fluid, instituting a metalworking fluid maintenance program at the site, and physically isolating the metalworking department from other departments. PMID:27494786

  1. Analysis of organophosphate hydraulic fluids in U.S. Air force base soils

    PubMed

    David; Seiber

    1999-04-01

    Tri-aryl and tri-alkyl organophosphates (TAPs) have been used extensively as flame-retardant hydraulic fluids and fluid additives in commercial and military aircraft. Up to 80% of the consumption of these fluids has been estimated to be lost to unrecovered leakage. Tri-aryl phosphate components of these fluids are resistant to volatilization and solubilization in water, thus, their primary environmental fate pathway is sorption to soils. Environmental audits of military air bases generally do not include quantification of these compounds in soils. We have determined the presence and extent of TAP contamination in soil samples from several U.S. Air Force bases. Soils were collected, extracted, and analyzed using GC/FPD and GC/MS. Tricresyl phosphate was the most frequently found TAP in soil, ranging from 0.02 to 130 ppm. Other TAPs in soils included triphenyl phosphate and isopropylated triphenyl phosphate. Observations are made regarding the distribution, typical concentrations, persistence, and need for further testing of TAPs in soils at military installations. Additionally, GC and mass spectral data for these TAPs are presented, along with methods for their extraction, sample clean-up, and quantification.

  2. Utility of Cytospin and Cell block Technology in Evaluation of Body Fluids and Urine Samples: A Comparative Study.

    PubMed

    Qamar, Irmeen; Rehman, Suhailur; Mehdi, Ghazala; Maheshwari, Veena; Ansari, Hena A; Chauhan, Sunanda

    2018-01-01

    Cytologic examination of body fluids commonly involves the use of direct or sediment smears, cytocentrifuge preparations, membrane filter preparations, or cell block sections. Cytospin and cell block techniques are extremely useful in improving cell yield of thin serous effusions and urine samples, and ensure high diagnostic efficacy. We studied cytospin preparations and cell block sections prepared from 180 samples of body fluids and urine samples to compare the relative efficiency of cell retrieval, preservation of cell morphology, ease of application of special stains, and diagnostic efficacy. Samples were collected and processed to prepare cytospin smears and cell block sections. We observed that overall, cell yield and preservation of individual cell morphology were better in cytospin preparations as compared to cell blocks, while preservation of architectural pattern was better in cell block sections. The number of suspicious cases also decreased on cell block sections, with increased detection of malignancy. It was difficult to prepare cell blocks from urine samples due to low cellularity. Cytospin technology is a quick, efficient, and cost-effective method of increasing cell yield in hypocellular samples, with better preservation of cell morphology. Cell blocks are better prepared from high cellularity fluids; however, tissue architecture is better studied, with improved rate of diagnosis and decrease in ambiguous results. Numerous sections can be prepared from a small amount of material. Special stains and immunochemical stains can be easily applied to cell blocks. It also provides a source of archival material.

  3. Paper-based microfluidic system for tear electrolyte analysis† †We declare no competing financial interests. ‡ ‡Electronic supplementary information (ESI) available: Microscopic images of G1 paper and G41 paper under brightfield; optimization of CO2 laser radiation fluence and beam speed for ablating filter paper-G1; photographs of DI water diffusion in microfluidic channels with different lengths, different widths, different viscosities of fluid and different numbers of channels; fluorescence intensity readouts of Na+ and K+ ions with varied concentrations of fluorescent probes; effect of variations in temperature on fluorescence intensity; photographs of DMSO on G1 paper dried in the air; calibration curves of electrolyte sensing on G1 paper using microplate reader measurement; calculation of sensitivity of the fluorescent sensors based on International Union of Pure and Applied Chemistry (IUPAC) guidelines; quantification of ion interference in buffer solution and artificial tear fluid; light attenuation of LED lights using different optical filters; the design of the sample collection device and its potential clinical use; calibration curves of electrolyte sensors using the paper-based microfluidic system; quantifications of evaporation effect on sampling process; design of the sample collection device and its potential clinical use; batch-to-batch variation experiments; equation for background subtraction; movies of sample collection and measurements. See DOI: 10.1039/c6lc01450j Click here for additional data file. Click here for additional data file. Click here for additional data file. Click here for additional data file.

    PubMed Central

    Jiang, Nan; Tamayol, Ali; Ruiz-Esparza, Guillermo U.; Zhang, Yu Shrike; Medina-Pando, Sofía; Gupta, Aditi; Wolffsohn, James S.; Butt, Haider; Khademhosseini, Ali

    2017-01-01

    The analysis of tear constituents at point-of-care settings has a potential for early diagnosis of ocular disorders such as dry eye disease, low-cost screening, and surveillance of at-risk subjects. However, current minimally-invasive rapid tear analysis systems for point-of-care settings have been limited to assessment of osmolarity or inflammatory markers and cannot differentiate between dry eye subclassifications. Here, we demonstrate a portable microfluidic system that allows quantitative analysis of electrolytes in the tear fluid that is suited for point-of-care settings. The microfluidic system consists of a capillary tube for sample collection, a reservoir for sample dilution, and a paper-based microfluidic device for electrolyte analysis. The sensing regions are functionalized with fluorescent crown ethers, o-acetanisidide, and seminaphtorhodafluor that are sensitive to mono- and divalent electrolytes, and their fluorescence outputs are measured with a smartphone readout device. The measured sensitivity values of Na+, K+, Ca2+ ions and pH in artificial tear fluid were matched with the known ion concentrations within the physiological range. The microfluidic system was tested with samples having different ionic concentrations, demonstrating the feasibility for the detection of early-stage dry eye, differential diagnosis of dry eye sub-types, and their severity staging. PMID:28207920

  4. Yolk protein is expressed in the insect testis and interacts with sperm

    PubMed Central

    Bebas, Piotr; Kotwica, Joanna; Joachimiak, Ewa; Giebultowicz, Jadwiga M

    2008-01-01

    Background Male and female gametes follow diverse developmental pathways dictated by their distinct roles in fertilization. While oocytes of oviparous animals accumulate yolk in the cytoplasm, spermatozoa slough off most of their cytoplasm in the process of individualization. Mammalian spermatozoa released from the testis undergo extensive modifications in the seminal ducts involving a variety of glycoproteins. Ultrastructural studies suggest that glycoproteins are involved in sperm maturation in insects; however, their characterization at the molecular level is lacking. We reported previously that the circadian clock controls sperm release and maturation in several insect species. In the moth, Spodoptera littoralis, the secretion of glycoproteins into the seminal fluid occurs in a daily rhythmic pattern. The purpose of this study was to characterize seminal fluid glycoproteins in this species and elucidate their role in the process of sperm maturation. Results We collected seminal fluid proteins from males before and after daily sperm release. These samples were separated by 2-D gel electrophoresis, and gels were treated with a glycoprotein-detecting probe. We observed a group of abundant glycoproteins in the sample collected after sperm release, which was absent in the sample collected before sperm release. Sequencing of these glycoproteins by mass spectroscopy revealed peptides bearing homology with components of yolk, which is known to accumulate in developing oocytes. This unexpected result was confirmed by Western blotting demonstrating that seminal fluid contains protein immunoreactive to antibody against yolk protein YP2 produced in the follicle cells surrounding developing oocytes. We cloned the fragment of yp2 cDNA from S. littoralis and determined that it is expressed in both ovaries and testes. yp2 mRNA and YP2 protein were detected in the somatic cyst cells enveloping sperm inside the testis. During the period of sperm release, YP2 protein appears in the seminal fluid and forms an external coat on spermatozoa. Conclusion One of the yolk protein precursors YP2, which in females accumulate in the oocytes to provision developing embryos, appears to have a second male-specific role. It is produced in the testes and released into the seminal fluid where it interacts with sperm. These data reveal unexpected common factor in the maturation of insect eggs and sperm. PMID:18549506

  5. Solubility classification of airborne uranium products collected at the perimeter of the Allied Chemical Plant, Metropolis, Illinois

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kalkwarf, D.R.

    1980-05-01

    Airborne uranium products were collected at the perimeter of the uranium-conversion plant operated by the Allied Chemical Corporation at Metropolis, Illinois, and the dissolution rates of these products were classified in terms of the ICRP Task Group Lung Model. Assignments were based on measurements of the dissolution half-times exhibited by uranium components of the dust samples as they dissolved in simulated lung fluid at 37/sup 0/C. Based on three trials, the dissolution behavior of dust with aerodynamic equivalent diameter (AED) less than 5.5 ..mu..m and collected nearest the closest residence to the plant was classified 0.40 D, 0.60 Y. Basedmore » on two trials, the dissolution behavior of dust with AED greater than 5.5 ..mu..m and collected at this location was classified 0.37 D, 0.63 Y. Based on one trial, the dissolution behavior of dust with AED less than 5.5 ..mu..m and collected at a location on the opposite side of the plant was classified 0.68 D, 0.32 Y. There was some evidence for adsorption of dissolved uranium onto other dust components during dissolution, and preliminary dissolution trials are recommended for future samples in order to optimize the fluid replacement schedule.« less

  6. Comparison of three methods of sampling trout blood for measurements of hematocrit

    USGS Publications Warehouse

    Steucke, Erwin W.; Schoettger, Richard A.

    1967-01-01

    Trout blood is frequently collected for hematocrit measurements by excising the caudal fin (Snieszko, 1960), but this technique is impractical if valuable fish are to be sampled or if repeated observations are desired. Schiffman (1959) and Snieszko (1960) collected blood from the dorsal aorta and the heart, but these methods are relatively slow and require the preparation of needles and syringes. The use of pointed capillary tubes for cardiac punctures increases the speed of sampling, but body fluids may dilute the blood (Perkins, 1957; Larsen and Snieszko, 1961; and Normandau, 1962). There is need for methods of sampling which are rapid and which neither influence hematological determinations nor harm the fish.

  7. Quantification of 11-Nor-9-Carboxy-Δ9-Tetrahydrocannabinol in Human Oral Fluid by Gas Chromatography–Tandem Mass Spectrometry

    PubMed Central

    Barnes, Allan J.; Scheidweiler, Karl B.; Huestis, Marilyn A.

    2015-01-01

    A sensitive and specific method for the quantification of 11-nor-9-carboxy-Δ9-tetrahydrocannabinol (THCCOOH) in oral fluid collected with the Quantisal and Oral-Eze devices was developed and fully validated. Extracted analytes were derivatized with hexafluoroisopropanol and trifluoroacetic anhydride and quantified by gas chromatography–tandem mass spectrometry with negative chemical ionization. Standard curves, using linear least-squares regression with 1/x2 weighting were linear from 10 to 1000 ng/L with coefficients of determination >0.998 for both collection devices. Bias was 89.2%–112.6%, total imprecision 4.0%–5.1% coefficient of variation, and extraction efficiency >79.8% across the linear range for Quantisal-collected specimens. Bias was 84.6%–109.3%, total imprecision 3.6%–7.3% coefficient of variation, and extraction efficiency >92.6% for specimens collected with the Oral-Eze device at all 3 quality control concentrations (10, 120, and 750 ng/L). This effective high-throughput method reduces analysis time by 9 minutes per sample compared with our current 2-dimensional gas chromatography–mass spectrometry method and extends the capability of quantifying this important oral fluid analyte to gas chromatography–tandem mass spectrometry. This method was applied to the analysis of oral fluid specimens collected from individuals participating in controlled cannabis studies and will be effective for distinguishing passive environmental contamination from active cannabis smoking. PMID:24622724

  8. Helium isotopes in matrix pore fluids from SAFOD drill core samples suggest mantle fluids cannot be responsible for fault weakening

    NASA Astrophysics Data System (ADS)

    Ali, S.; Stute, M.; Torgersen, T.; Winckler, G.

    2008-12-01

    To quantify fluid flow in the San Andreas Fault (SAF) (and since direct fracture fluid sampling of the fault zone was not available), we have adapted a method to extract rare gases from matrix fluids of whole rocks by diffusion. Helium was measured on drill core samples obtained from 3054 m (Pacific Plate) to 3990 m (North American Plate) through the San Andreas Fault Zone (SAFZ) ~3300 m during SAFOD Phases I (2004), II (2005), III (2007). Samples were typically collected as 2.54 cm diameter subcores drilled into the ends of the cores, or from the core catcher and drillcore fragments within <2hr after core recovery. The samples were placed into ultra high vacuum stainless steel containers, flushed with ultra high purity nitrogen and immediately evacuated. Helium isotopes of the extracted matrix pore fluids and the solid matrix were determined by mass spectrometery at LDEO. Matrix porefluid 3He/4He ratios are ~0.4 - 0.5xRa (Ra: atmospheric 3He/4He = 1.384 x 10-6) in the Pacific Plate, increasing toward the SAFZ, while pore fluids in the North American Plate have a 3He/4He range of 0.7-0.9Ra, increasing away from the SAFZ (consistent with results from mud gas samples (Wiersberg and Erzinger, 2007) and direct fluid samples (Kennedy et al., 2007)). Helium isotope ratios of the solid matrix are less than 0.06Ra across the SAF in samples from both the North American and the Pacific plates, thereby excluding the host matrix as source for the enhanced isotopic signature. If the system is assumed to be in steady state, then the flux of mantle helium must be from the North American Plate to the Pacific plate. The steeper gradient in the Pacific Plate relative to the North American plate is consistent with a porosity corrected effective diffusivity. The source for this mantle helium in the North American Plate is likely related to a low crustal conductivity zone identified by magnetotelluric signals (Becken et al., 2008) that provides a channel for transport of mantle helium within brittle crust under high strain rates (Kennedy et al., 2007). The helium isotope gradients suggest that fault weakening by mantle-derived fluid pressure is unlikely. More likely, mantle fluids "bleed" into the North American plate below seismogenic depths and are transported across the fault by nonseismic, diffusive processes.

  9. Appraisal of transport and deformation in shale reservoirs using natural noble gas tracers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Heath, Jason E.; Kuhlman, Kristopher L.; Robinson, David G.

    2015-09-01

    This report presents efforts to develop the use of in situ naturally-occurring noble gas tracers to evaluate transport mechanisms and deformation in shale hydrocarbon reservoirs. Noble gases are promising as shale reservoir diagnostic tools due to their sensitivity of transport to: shale pore structure; phase partitioning between groundwater, liquid, and gaseous hydrocarbons; and deformation from hydraulic fracturing. Approximately 1.5-year time-series of wellhead fluid samples were collected from two hydraulically-fractured wells. The noble gas compositions and isotopes suggest a strong signature of atmospheric contribution to the noble gases that mix with deep, old reservoir fluids. Complex mixing and transport of fracturingmore » fluid and reservoir fluids occurs during production. Real-time laboratory measurements were performed on triaxially-deforming shale samples to link deformation behavior, transport, and gas tracer signatures. Finally, we present improved methods for production forecasts that borrow statistical strength from production data of nearby wells to reduce uncertainty in the forecasts.« less

  10. Matrix isolation apparatus with extended sample collection capability

    DOEpatents

    Reedy, Gerald T.

    1987-01-01

    A gas-sample collection device provides for the matrix isolation of increased amounts of a sample material for spectrographic analysis from a gas chromatographic separation. The device includes an evacuated sample collection chamber containing a disc-like specular carousel having a generally circular lateral surface upon which the sample is deposited in an inert gas matrix for infrared (IR) spectral analysis. The evacuated sample chamber is mounted in a fixed manner and is coupled to and supports a rotating cryostatic coupler which, in turn, supports the specular carousel within the collection chamber. A rotational drive system connected to the cryostatic coupler provides for its rotational displacement as well as that of the sample collecting carousel. In addition, rotation of the cryostatic coupler effects vertical displacement of the carousel to permit the collection of an extended sample band in a helical configuration on the entire lateral surface of the carousel. The various components of the carousel's angular/linear displacement drive system are located exterior to the cryostatic coupler for easy access and improved operation. The cryostatic coupler includes a 360.degree. rotary union assembly for permitting the delivery of a high pressure working fluid to the cryostatic coupler in a continuous flow manner for maintaining the specular carousel at a low temperature, e.g., 10.degree.-20.degree. K., for improved uninterrupted gas sample collection and analysis.

  11. Determination of the bioaccessible fraction of metals in urban aerosol using simulated lung fluids

    NASA Astrophysics Data System (ADS)

    Coufalík, Pavel; Mikuška, Pavel; Matoušek, Tomáš; Večeřa, Zbyněk

    2016-09-01

    Determination of the bioaccessible fraction of metals in atmospheric aerosol is a significant issue with respect to air pollution in the urban environment. The aim of this work was to compare of metal bioaccessibility determined according to the extraction yields of six simulated lung fluids. Aerosol samples of the PM1 fraction were collected in Brno, Czech Republic. The total contents of Cd, Ce, Cr, Cu, Fe, Mn, Ni, Pb, V, and Zn in the samples were determined and their enrichment factors were calculated. The bioaccessible proportions of elements were determined by means of extraction in Gamble's solution, Gamble's solution with dipalmitoyl phosphatidyl choline (DPPC), artificial lysosomal fluid, saline, water, and in a newly proposed solution based on DPPC, referred to as "Simulated Alveoli Fluid" (SAF). The chemical composition and surface tension of the simulated lung fluids were the main parameters influencing extraction yields. Gamble's solutions and the newly designed solution of SAF exhibited the lowest extraction efficiency, and also had the lowest surface tensions. The bioaccessibility of particulate metals should be assessed by synthetic lung fluids with a low surface tension, which simulate better the behavior and composition of native lung surfactant. The bioaccessibility of metals in aerosol assessed by means of the extraction in water or artificial lysosomal fluid can be overestimated.

  12. Infectious hematopoietic necrosis virus detected by separation and incubation of cells from salmonid cavity fluid.

    USGS Publications Warehouse

    Mulcahy, D.; Batts, W.N.

    1987-01-01

    Infectious hematopoietic necrosis (IHN) virus is usually detected by inoculating susceptible cell cultures with cavity ("ovarian") fluid (CF) from spawning females. We identified additional adult carriers of virus in spawning populations of steelhead trout (Salmo gairdneri) and sockeye salmon (Oncorhynchus nerka) by collecting nonerythrocytic cells from CF samples by low-speed centrifugation, culturing the cells for at least 7 d at 15 °C, and then testing the culture medium for virus. Virus appeared in the cultured cells from some samples of CF that remained negative during incubation. In additional samples of CF from these species, the virus titer increased in cultured cells compared with the titer in the original CF sample. With chinook salmon (O.tshawytscha), no negative samples converted to positive during incubation, but the virus titer was retained in incubated CF cells, but not in cell-free CF.

  13. A comparison of manual and electronic counting for total nucleated cell counts on synovial fluid from canine stifle joints.

    PubMed

    Atilola, M A; Lumsden, J H; Rooke, F

    1986-04-01

    Synovial fluids collected from the stifle joints of 20 physically normal adult dogs were subjected to cytological examination. A total nucleated cell count was performed on each sample using both an electronic cell counter and a hemocytometer. The mean of the total counts done with the electronic counter was significantly higher (1008 cells/microL) than that obtained manually with the hemocytometer (848 cells/microL).

  14. Technical note: A simple rumen collection device for calves: An adaptation of a manual rumen drenching system.

    PubMed

    Klopp, R N; Oconitrillo, M J; Sackett, A; Hill, T M; Schlotterbeck, R L; Lascano, G J

    2018-07-01

    A limited amount of research is available related to the rumen microbiota of calves, yet there has been a recent spike of interest in determining the diversity and development of calf rumen microbial populations. To study the microbial populations of a calf's rumen, a sample of the rumen fluid is needed. One way to take a rumen fluid sample from a calf is by fistulating the animal. This method requires surgery and can be very stressful on a young animal that is trying to adapt to a new environment and has a depressed immune system. Another method that can be used instead of fistulation surgery is a rumen pump. This method requires a tube to be inserted into the rumen through the calf's esophagus. Once inside the rumen, fluid can be pumped out and collected in a few minutes. This method is quick, inexpensive, and does not cause significant stress on the animal. This technical note presents the materials and methodology used to convert a drenching system into a rumen pump and its respective utilization in 2 experiments using dairy bull calves. Copyright © 2018 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  15. LC/ESI-MS/MS method for quantification of 28 synthetic cannabinoids in neat oral fluid and its application to preliminary studies on their detection windows.

    PubMed

    Kneisel, Stefan; Speck, Michael; Moosmann, Bjoern; Corneillie, Todd M; Butlin, Nathaniel G; Auwärter, Volker

    2013-05-01

    Serum and urine samples are commonly used for the analysis of synthetic cannabinoids in biofluids; however, their utilization as analytical matrices for drug abstinence control features some substantial drawbacks. While for blood collection invasive sampling is inevitable, the urinary analysis of synthetic cannabinoids is limited by the lack of available reference standards of the respective major metabolites. Moreover, the long detectability of synthetic cannabinoids in both matrices hampers the identification of a recent synthetic cannabinoid use. This article describes the development, validation and application of an LC/ESI-MS/MS method for the quantification of 28 synthetic cannabinoids in neat oral fluid (OF) samples. OF samples were prepared by protein precipitation using ice-cold acetonitrile. Chromatographic separation was achieved by gradient elution on a Luna Phenyl Hexyl column (50 × 2 mm, 5 μm), while detection was carried out on a QTrap 4000 instrument in positive ionization mode. The limits of detection ranged from 0.02 to 0.40 ng/mL, whereas the lower limits of quantification ranged from 0.2 to 4.0 ng/mL. The method was applied to authentic samples collected during two preliminary studies in order to obtain insights into the general detectability and detection windows of synthetic cannabinoids in this matrix. The results indicate that synthetic cannabinoids are transferred from the blood stream into OF and vice versa only at a very low rate. Therefore, positive OF samples are due to contamination of the oral cavity during smoking. As these drug-contaminations could be detected up to approximately 2 days, neat oral fluid appears to be well suited for detection of a recent synthetic cannabinoid use.

  16. Detecting alcohol and illicit drugs in oral fluid samples collected from truck drivers in the state of São Paulo, Brazil.

    PubMed

    Yonamine, Mauricio; Sanches, Livia Rentas; Paranhos, Beatriz Aparecida Passos Bismara; de Almeida, Rafael Menck; Andreuccetti, Gabriel; Leyton, Vilma

    2013-01-01

    Alcohol and drug use by truck drivers is a current problem in Brazil. Though there is evidence that alcohol consumption is occurring in higher proportions, the use of stimulant drugs to avoid fatigue and to maintain the work schedule has also been reported. The purpose of this study was to estimate the incidence of alcohol and illicit drug use among truck drivers on São Paulo state roads. São Paulo is the most populous state in Brazil and has the largest industrial park and economic production in the country. Data were assessed not only using a questionnaire but also, and more reliably, through toxicological analysis of oral fluid samples. Between the years 2002 and 2008, 1250 oral fluid samples were collected from truck drivers on the roads during morning hours. The samples were tested for the presence of alcohol, cocaine, tetrahydrocannabinol (THC), and amphetamine/methamphetamine. A previously published, validated gas chromatographic (gas chromatography-flame ionization detection and gas chromatography-mass spectrometry) method was applied to the samples for alcohol and drug detection. Of the total analyzed samples, 3.1 percent (n = 39) were positive: 1.44 percent (n = 18) were positive for alcohol, 0.64 percent (n = 8) for amphetamines, 0.56 percent (n = 7) for cocaine, and 0.40 percent (n = 5) for THC. In one case, cocaine and THC were detected. The results are indicative of the extent of alcohol and drug use by truck drivers in the state of São Paulo, Brazil. This research provides evidence that not only alcohol but also illicit drug use is a real problem among professional drivers. The use of these substances should be controlled to better promote safe driving conditions on Brazilian roads.

  17. A Pilot Study of the Noninvasive Assessment of the Lung Microbiota as a Potential Tool for the Early Diagnosis of Ventilator-Associated Pneumonia

    PubMed Central

    Brady, Jacob S.; Romano-Keeler, Joann; Drake, Wonder P.; Norris, Patrick R.; Jenkins, Judith M.; Isaacs, Richard J.; Boczko, Erik M.

    2015-01-01

    BACKGROUND: Ventilator-associated pneumonia (VAP) remains a common complication in critically ill surgical patients, and its diagnosis remains problematic. Exhaled breath contains aerosolized droplets that reflect the lung microbiota. We hypothesized that exhaled breath condensate fluid (EBCF) in hygroscopic condenser humidifier/heat and moisture exchanger (HCH/HME) filters would contain bacterial DNA that qualitatively and quantitatively correlate with pathogens isolated from quantitative BAL samples obtained for clinical suspicion of pneumonia. METHODS: Forty-eight adult patients who were mechanically ventilated and undergoing quantitative BAL (n = 51) for suspected pneumonia in the surgical ICU were enrolled. Per protocol, patients fulfilling VAP clinical criteria undergo quantitative BAL bacterial culture. Immediately prior to BAL, time-matched HCH/HME filters were collected for study of EBCF by real-time polymerase chain reaction. Additionally, convenience samples of serially collected filters in patients with BAL-diagnosed VAP were analyzed. RESULTS: Forty-nine of 51 time-matched EBCF/BAL fluid samples were fully concordant (concordance > 95% by κ statistic) relative to identified pathogens and strongly correlated with clinical cultures. Regression analysis of quantitative bacterial DNA in paired samples revealed a statistically significant positive correlation (r = 0.85). In a convenience sample, qualitative and quantitative polymerase chain reaction analysis of serial HCH/HME samples for bacterial DNA demonstrated an increase in load that preceded the suspicion of pneumonia. CONCLUSIONS: Bacterial DNA within EBCF demonstrates a high correlation with BAL fluid and clinical cultures. Bacterial DNA within EBCF increases prior to the suspicion of pneumonia. Further study of this novel approach may allow development of a noninvasive tool for the early diagnosis of VAP. PMID:25474571

  18. Experimental Evaluation of Equivalent-Fluid Models for Melamine Foam

    NASA Technical Reports Server (NTRS)

    Allen, Albert R.; Schiller, Noah H.

    2016-01-01

    Melamine foam is a soft porous material commonly used in noise control applications. Many models exist to represent porous materials at various levels of fidelity. This work focuses on rigid frame equivalent fluid models, which represent the foam as a fluid with a complex speed of sound and density. There are several empirical models available to determine these frequency dependent parameters based on an estimate of the material flow resistivity. Alternatively, these properties can be experimentally educed using an impedance tube setup. Since vibroacoustic models are generally sensitive to these properties, this paper assesses the accuracy of several empirical models relative to impedance tube measurements collected with melamine foam samples. Diffuse field sound absorption measurements collected using large test articles in a laboratory are also compared with absorption predictions determined using model-based and measured foam properties. Melamine foam slabs of various thicknesses are considered.

  19. Metagenomic Assessment of a Dynamic Microbial Population from Subseafloor Aquifer Fluids in the Cold, Oxygenated Crust

    NASA Astrophysics Data System (ADS)

    Tully, B. J.; Heidelberg, J. F.; Kraft, B.; Girguis, P. R.; Huber, J. A.

    2016-12-01

    The oceanic crust contains the largest aquifer on Earth with a volume approximately 2% of the global ocean. Ongoing research at the North Pond (NP) site, west of the Mid-Atlantic Ridge, provides an environment representative of oxygenated crustal aquifers beneath oligotrophic surface waters. Using subseafloor CORK observatories for multiple sampling depths beneath the seafloor, crustal fluids were sampled along the predicted aquifer fluid flow path over a two-year period. DNA was extracted and sequenced for metagenomic analysis from 22 crustal fluid samples, along with the overlying bottom. At broad taxonomic groupings, the aquifer system is highly dynamic over time and space, with shifts in dominant taxa and "blooms" of transient groups that appear at discreet time points and sample depths. We were able to reconstruct 194 high-quality, low-contamination bacterial and archaeal metagenomic-assembled genomes (MAGs) with estimated completeness >50% (429 MAGs >20% complete). Environmental genomes were assigned to phylogenies from the major bacterial phyla, putative novel groups, and poorly sampled phylogenetic groups, including the Marinimicrobia, Candidate Phyla Radiation, and Planctomycetes. Biogeochemically relevant processes were assigned to MAGs, including denitrification, dissimilatory sulfur and hydrogen cycling, and carbon fixation. Collectively, the oxic NP aquifer system represents a diverse, dynamic microbial habitat with the metabolic potential to impact multiple globally relevant biogeochemical cycles, including nitrogen, sulfur, and carbon.

  20. Flow-controlled magnetic particle manipulation

    DOEpatents

    Grate, Jay W [West Richland, WA; Bruckner-Lea, Cynthia J [Richland, WA; Holman, David A [Las Vegas, NV

    2011-02-22

    Inventive methods and apparatus are useful for collecting magnetic materials in one or more magnetic fields and resuspending the particles into a dispersion medium, and optionally repeating collection/resuspension one or more times in the same or a different medium, by controlling the direction and rate of fluid flow through a fluid flow path. The methods provide for contacting derivatized particles with test samples and reagents, removal of excess reagent, washing of magnetic material, and resuspension for analysis, among other uses. The methods are applicable to a wide variety of chemical and biological materials that are susceptible to magnetic labeling, including, for example, cells, viruses, oligonucleotides, proteins, hormones, receptor-ligand complexes, environmental contaminants and the like.

  1. Xylem sap proteins.

    PubMed

    Biles, C L; Abeles, F B

    1991-06-01

    Xylem sap from apple (Malus domestica Borkh), peach (Prunus persica Batsch), and pear (Pyrus communis L.) twigs was collected by means of pressure extrusion. This sap contained a number of acidic peroxidases and other proteins. Two other sources of xylem sap used in this study were stem exudates and guttation fluid. Similar peroxidases were also found in stem exudates and guttation fluids of strawberry (Fragaria x ananassa Duch.), tomato (Lycopersicum esculentum L.), and cucumber (Cucumis sativus L.). Isoelectric focusing activity gels showed that two peroxidases (isoelectric point [pl] 9 and pl 4.6) were present in initial stem exudates collected in the first 30 minutes after excision. Subsequent samples of stem exudate collected contained only the pl 4.6 isozyme. The pl 4.6 peroxidase isozyme was also found in root tissue and guttation fluid. These observations suggest that roots produce and secrete the pl 4.6 peroxidase into xylem sap. Cucumber seedlings were treated with 100 microliters per liter ethylene for 16 hours and the exudate from decapitated hypocotyl stumps was collected over a 3 hour period. Ethylene increased the peroxidase activity of stem exudates and inhibited the amount of exudate released. These observations suggest that xylem sap peroxidase may play a role in plugging damaged vascular tissue.

  2. Comparison of blood chemistry values for samples collected from juvenile chinook salmon by three methods

    USGS Publications Warehouse

    Congleton, J.L.; LaVoie, W.J.

    2001-01-01

    Thirteen blood chemistry indices were compared for samples collected by three commonly used methods: caudal transection, heart puncture, and caudal vessel puncture. Apparent biases in blood chemistry values for samples obtained by caudal transection were consistent with dilution with tissue fluids: alanine aminotransferase (ALT), aspartate aminotransferase (AST), lactate dehydrogenase (LDH), creatine kinase (CK), triglyceride, and K+ were increased and Na+ and Cl- were decreased relative to values for samples obtained by caudal vessel puncture. Some enzyme activities (ALT, AST, LDH) and K+ concentrations were also greater in samples taken by heart puncture than in samples taken by caudal vessel puncture. Of the methods tested, caudal vessel puncture had the least effect on blood chemistry values and should be preferred for blood chemistry studies on juvenile salmonids.

  3. DNA methylation profiling for a confirmatory test for blood, saliva, semen, vaginal fluid and menstrual blood.

    PubMed

    Lee, Hwan Young; Jung, Sang-Eun; Lee, Eun Hee; Yang, Woo Ick; Shin, Kyoung-Jin

    2016-09-01

    The ability to predict the type of tissues or cells from molecular profiles of crime scene samples has important practical implications in forensics. A previously reported multiplex assay using DNA methylation markers could only discriminate between 4 types of body fluids: blood, saliva, semen, and the body fluid which originates from female reproductive organ. In the present study, we selected 15 menstrual blood-specific CpG marker candidates based on analysis of 12 genome-wide DNA methylation profiles of vaginal fluid and menstrual blood. The menstrual blood-specificity of the candidate markers was confirmed by comparison with HumanMethylation450 BeadChip array data obtained for 58 samples including 12 blood, 12 saliva, 12 semen, 3 vaginal fluid, and 19 skin epidermis samples. Among 15CpG marker candidates, 3 were located in the promoter region of the SLC26A10 gene, and 2 of them (cg09696411 and cg18069290) showed high menstrual blood specificity. DNA methylation at the 2CpG markers was further tested by targeted bisulfite sequencing of 461 additional samples including 49 blood, 52 saliva, 34 semen, 125 vaginal fluid, and 201 menstrual blood. Because the 2 markers showed menstrual blood-specific methylation patterns, we modified our previous multiplex methylation SNaPshot reaction to include these 2 markers. In addition, a blood marker cg01543184 with cross reactivity to semen was replaced with cg08792630, and a semen-specific unmethylation marker cg17621389 was removed. The resultant multiplex methylation SNaPshot allowed positive identification of blood, saliva, semen, vaginal fluid and menstrual blood using the 9CpG markers which show a methylation signal only in the target body fluids. Because of the complexity in cell composition, menstrual bloods produced DNA methylation profiles that vary with menstrual cycle and sample collection methods, which are expected to provide more insight into forensic menstrual blood test. Moreover, because the developed multiplex methylation SNaPshot reaction includes the 4CpG markers of which specificities have been confirmed by multiple studies, it will facilitate confirmatory tests for body fluids that are frequently observed in forensic casework. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  4. From the Belly of the Beast: Biogeochemistry and geomicrobiology of a fluid seep at Chimaera [Yanartas], Turkey

    NASA Astrophysics Data System (ADS)

    Woycheese, K. M.; Yargicoglu, E. N.; Cardace, D.; Meyer-Dombard, D. R.

    2012-12-01

    Serpentinization is proposed to support chemolithotrophic growth of microorganisms in surface and subsurface environments1. Abiotic CH4 production associated with terrestrial ophiolitic outcrops has been reported in southeastern Turkey2. The Yanartas (Chimaera) seep, located within the Tekirova ophiolite in Çirali, Antalya, Turkey, is one of the largest onshore CH4 seeps documented2-5. The seep consists of dozens of flames erupting from fractures within the ophiolite outcrop that burn continuously on CH4 (80-90% of gas composition2) produced by subsurface serpentinization reactions. Previous studies have focused on gas geochemistry from these seeps2, 4, 5. While past reports have not found active fluid seeps at Yanartas2, in February 2012, a fluid seep (possibly ephemeral) originating from a fracture was identified, which supported microbial mats over an outflow channel several m in length. This is the first investigation of the biogeochemical and geomicrobiological properties of this newly-discovered fluid seep. The fluid seep emits from a fracture that is actively burning, and travels down slope along the ophiolite outcrop for ~10 m. Sediment temperatures under the vent source were 50-60°C, while fluid emitting from the fracture was 18.5°C. The pH of the fluid at the vent source was 11.9, indicative of subterranean serpentinization. Approximately 7.3 m downstream, the pH dropped to 9.4, potentially due to meteoric water mixing. Fluid samples were collected along the outflow channel for major ion analysis, trace element analysis, dissolved inorganic carbon (DIC), and dissolved organic carbon (DOC). Biofilm and biomineralized microbial mats were collected for bulk C and N composition, 13C and 15N isotopes, and microscopy. Weight % total C (CT) in solids generally increases with distance from the source, while weight % organic C (Corg) decreases, reflective of a higher degree of carbonate biomineralization downstream. δ13C of solids indicates a general trend of increased 13C enrichment with distance from the source in both Corg and CT. δ15N becomes more positive with distance from the source, and does not suggest active nitrogen fixation along the outflow channel. Scanning electron microscopy (SEM) equipped with X-ray energy dispersive spectroscopy (XEDS) and X-ray diffraction (XRD) confirms that the biomineralized microbial mats are primarily composed of carbonates. Microbial samples were collected for cultivation, phylogenetic and function-based DNA analysis. Samples will be screened for methanotrophy, C fixation, and N cycling. Successful cultures have been obtained from Yanartas samples, demonstrating growth on a wide variety of carbon substrates (e.g. organic acids, yeast extract, peptone, and sugars). This is the first report of biofilms and surface fluids associated with serpentinization at the Yanartas seep. 1. McCollom, T.M. & W. Bach (2009) GCA. 73(3): 856-875 2. Etiope, G.; Schoell, M. & H. Hosgörmez (2011) EPSL. 310: 96-104 3. de Boer, J.Z.; Chanton, J. & M. Zeitlhöfler (2007) Geowissenshaftliche. 158(4): 997-1003 4. Hosgörmez, H. (2007) J Asian Earth Sci. 30: 131-141

  5. Protein Detection Using the Multiplexed Proximity Extension Assay (PEA) from Plasma and Vaginal Fluid Applied to the Indicating FTA Elute Micro Card™

    PubMed Central

    Berggrund, Malin; Ekman, Daniel; Gustavsson, Inger; Sundfeldt, Karin; Olovsson, Matts; Enroth, Stefan; Gyllensten, Ulf

    2016-01-01

    The indicating FTA elute micro card™ has been developed to collect and stabilize the nucleic acid in biological samples and is widely used in human and veterinary medicine and other disciplines. This card is not recommended for protein analyses, since surface treatment may denature proteins. We studied the ability to analyse proteins in human plasma and vaginal fluid as applied to the indicating FTA elute micro card™ using the sensitive proximity extension assay (PEA). Among 92 proteins in the Proseek Multiplex Oncology Iv2 panel, 87 were above the limit of detection (LOD) in liquid plasma and 56 among 92 above LOD in plasma applied to FTA cards. Washing and protein elution protocols were compared to identify an optimal method. Liquid-based cytology samples showed a lower number of proteins above LOD than FTA cards with vaginal fluid samples applied. Our results demonstrate that samples applied to the indicating FTA elute micro card™ are amendable to protein analyses, given that a sensitive protein detection assay is used. The results imply that biological samples applied to FTA cards can be used for DNA, RNA and protein detection. PMID:28936257

  6. Protein Detection Using the Multiplexed Proximity Extension Assay (PEA) from Plasma and Vaginal Fluid Applied to the Indicating FTA Elute Micro Card™.

    PubMed

    Berggrund, Malin; Ekman, Daniel; Gustavsson, Inger; Sundfeldt, Karin; Olovsson, Matts; Enroth, Stefan; Gyllensten, Ulf

    2016-01-01

    The indicating FTA elute micro card™ has been developed to collect and stabilize the nucleic acid in biological samples and is widely used in human and veterinary medicine and other disciplines. This card is not recommended for protein analyses, since surface treatment may denature proteins. We studied the ability to analyse proteins in human plasma and vaginal fluid as applied to the indicating FTA elute micro card™ using the sensitive proximity extension assay (PEA). Among 92 proteins in the Proseek Multiplex Oncology Iv2 panel, 87 were above the limit of detection (LOD) in liquid plasma and 56 among 92 above LOD in plasma applied to FTA cards. Washing and protein elution protocols were compared to identify an optimal method. Liquid-based cytology samples showed a lower number of proteins above LOD than FTA cards with vaginal fluid samples applied. Our results demonstrate that samples applied to the indicating FTA elute micro card™ are amendable to protein analyses, given that a sensitive protein detection assay is used. The results imply that biological samples applied to FTA cards can be used for DNA, RNA and protein detection.

  7. Comparison of serum pools and oral fluid samples for detection of porcine circovirus type 2 by quantitative real-time PCR in finisher pigs.

    PubMed

    Nielsen, Gitte Blach; Nielsen, Jens Peter; Haugegaard, John; Leth, Sanne Christiansen; Larsen, Lars E; Kristensen, Charlotte Sonne; Pedersen, Ken Steen; Stege, Helle; Hjulsager, Charlotte K; Houe, Hans

    2018-01-01

    Porcine circovirus type 2 (PCV2) diagnostics in live pigs often involves pooled serum and/or oral fluid samples for group-level determination of viral load by quantitative real-time polymerase chain reaction (qPCR). The purpose of the study was to compare the PCV2 viral load determined by qPCR of paired samples at the pen level of pools of sera (SP) from 4 to 5 pigs and the collective oral fluid (OF) from around 30 pigs corresponding to one rope put in the same pen. Pigs in pens of 2 finishing herds were sampled by cross-sectional (Herd 1) and cross-sectional with follow-up (Herd 2) study designs. In Herd 1, 50 sample pairs consisting of SP from 4 to 5 pigs and OF from around 23 pigs were collected. In Herd 2, 65 sample pairs consisting of 4 (SP) and around 30 (OF) pigs were collected 4 times at 3-week intervals. A higher proportion of PCV2-positive pens (86% vs. 80% and 100% vs. 91%) and higher viral loads (mean difference: 2.10 and 1.83 log(10) PCV2 copies per ml) were found in OF versus SP in both herds. The OF cut-off value corresponding to a positive SP (>3 log(10) PCV2 copies per ml) was estimated to 6.5 and 7.36 log(10) PCV2 copies per ml for Herds 1 and 2, respectively. Significant correlations between SP and OF results were found in Herd 1 (rho = 0.69) and the first sampling in Herd 2 (rho = 0.39), but not for the subsequent consecutive 3 samplings in Herd 2. The proportion and viral loads of PCV2 positive pens were higher in collective OF (including up to 30 pigs) compared to SP (including 4-5 pigs) of the same pens. Also, OF seemed to detect the PCV2 infection earlier with OF values just below 6.5 (Herd 1) and 7.36 (Herd 2) log(10) being associated with a negative SP for the same pen. Nevertheless, a statistically significant correlation between SP and OF could not be found for all sampling time points, probably due to a high within-pen variation in individual pig viral load becoming very evident in SP of only four or five pigs. Consequently, the results imply that OF is well suited for detecting presence of PCV2 but less so for determining the specific viral load of pigs in a pen.

  8. Raman spectroscopy of synovial fluid as a tool for diagnosing osteoarthritis

    NASA Astrophysics Data System (ADS)

    Esmonde-White, Karen A.; Mandair, Gurjit S.; Raaii, Farhang; Jacobson, Jon A.; Miller, Bruce S.; Urquhart, Andrew G.; Roessler, Blake J.; Morris, Michael D.

    2009-05-01

    For many years, viscosity has been the primary method used by researchers in rheumatology to assess the physiochemical properties of synovial fluid in both normal and osteoarthritic patients. However, progress has been limited by the lack of methods that provide multiple layers of information, use small sample volumes, and are rapid. Raman spectroscopy was used to assess the biochemical composition of synovial fluid collected from 40 patients with clinical evidence of knee osteoarthritis (OA) at the time of elective surgical treatment. Severity of knee osteoarthritis was assessed by a radiologist using Kellgren/Lawrence (K/L) scores from knee joint x rays, while light microscopy and Raman spectroscopy were used to examine synovial fluid (SF) aspirates (2 to 10 μL), deposited on fused silica slides. We show that Raman bands used to describe protein secondary structure and content can be used to detect changes in synovial fluid from osteoarthritic patients. Several Raman band intensity ratios increased significantly in spectra collected from synovial fluid in patients with radiological evidence of moderate-to-severe osteoarthritis damage. These ratios can be used to provide a ``yes/no'' damage assessment. These studies provide evidence that Raman spectroscopy would be a suitable candidate in the evaluation of joint damage in knee osteoarthritis patients.

  9. Continuous separation of microparticles in a microfluidic channel via the elasto-inertial effect of non-Newtonian fluid.

    PubMed

    Nam, Jeonghun; Lim, Hyunjung; Kim, Dookon; Jung, Hyunwook; Shin, Sehyun

    2012-04-07

    Pure separation and sorting of microparticles from complex fluids are essential for biochemical analyses and clinical diagnostics. However, conventional techniques require highly complex and expensive labeling processes for high purity separation. In this study, we present a simple and label-free method for separating microparticles with high purity using the elasto-inertial characteristic of a non-Newtonian fluid in microchannel flow. At the inlet, particle-containing sample flow was pushed toward the side walls by introducing sheath fluid from the center inlet. Particles of 1 μm and 5 μm in diameter, which were suspended in viscoelastic fluid, were successfully separated in the outlet channels: larger particles were notably focused on the centerline of the channel at the outlet, while smaller particles continued flowing along the side walls with minimal lateral migration towards the centerline. The same technique was further applied to separate platelets from diluted whole blood. Through cytometric analysis, we obtained a purity of collected platelets of close to 99.9%. Conclusively, our microparticle separation technique using elasto-inertial forces in non-Newtonian fluid is an effective method for separating and collecting microparticles on the basis of size differences with high purity. This journal is © The Royal Society of Chemistry 2012

  10. Microbial Community in the Hydrothermal System at Southern Mariana Trough

    NASA Astrophysics Data System (ADS)

    Kato, S.; Itahashi, S.; Kakegawa, T.; Utsumi, M.; Maruyama, A.; Ishibashi, J.; Marumo, K.; Urabe, T.; Yamagishi, A.

    2004-12-01

    There is unique ecosystem around deep-sea hydrothermal area. Living organisms are supported by chemical free energy provided by the hydrothermal water. The ecosystem is expected to be similar to those in early stage of life history on the earth, when photosynthetic organisms have not emerged. In this study, we have analyzed the microbial diversity in the hydrothermal area at southern Mariana trough. In the "Archaean Park Project" supported by special Coordination Fund, four holes were bored and cased by titanium pipes near hydrothermal vents in the southern Mariana trough in 2004. Hydrothermal fluids were collected from these cased holes and natural vents in this area. Microbial cells were collected by filtering the hydrothermal fluid in situ or in the mother sip. Filters were stored at -80C and used for DNA extraction. Chimneys at this area was also collected and stored at -80C. The filters and chimney samples were crushed and DNA was extracted. DNA samples were used for amplification of 16S rDNA fragments by PCR using archaea specific primers and universal primers. The PCR fragments were cloned and sequenced. These PCR clones of different samples will be compared. We will extend our knowledge about microbiological diversity at Southern Mariana trough to compare the results obtained at other area.

  11. Perilymph sampling from the cochlear apex: a reliable method to obtain higher purity perilymph samples from scala tympani.

    PubMed

    Salt, Alec N; Hale, Shane A; Plonkte, Stefan K R

    2006-05-15

    Measurements of drug levels in the fluids of the inner ear are required to establish kinetic parameters and to determine the influence of specific local delivery protocols. For most substances, this requires cochlear fluids samples to be obtained for analysis. When auditory function is of primary interest, the drug level in the perilymph of scala tympani (ST) is most relevant, since drug in this scala has ready access to the auditory sensory cells. In many prior studies, ST perilymph samples have been obtained from the basal turn, either by aspiration through the round window membrane (RWM) or through an opening in the bony wall. A number of studies have demonstrated that such samples are likely to be contaminated with cerebrospinal fluid (CSF). CSF enters the basal turn of ST through the cochlear aqueduct when the bony capsule is perforated or when fluid is aspirated. The degree of sample contamination has, however, not been widely appreciated. Recent studies have shown that perilymph samples taken through the round window membrane are highly contaminated with CSF, with samples greater than 2microL in volume containing more CSF than perilymph. In spite of this knowledge, many groups continue to sample from the base of the cochlea, as it is a well-established method. We have developed an alternative, technically simple method to increase the proportion of ST perilymph in a fluid sample. The sample is taken from the apex of the cochlea, a site that is distant from the cochlear aqueduct. A previous problem with sampling through a perforation in the bone was that the native perilymph rapidly leaked out driven by CSF pressure and was lost to the middle ear space. We therefore developed a procedure to collect all the fluid that emerged from the perforated apex after perforation. We evaluated the method using a marker ion trimethylphenylammonium (TMPA). TMPA was applied to the perilymph of guinea pigs either by RW irrigation or by microinjection into the apical turn. The TMPA concentration of the fluid sample was compared with that measured in perilymph prior to taking the sample using a TMPA-selective microelectrode sealed into ST. Data were interpreted with a finite element model of the cochlear fluids that was used to simulate each aspect of the experiment. The correction of sample concentration back to the perilymph concentration prior to sampling can be performed based on the known ST volume (4.7microL in the guinea pig) and the sample volume. A more precise correction requires some knowledge of the profile of drug distribution along the cochlear prior to sampling. This method of sampling from the apex is technically simple and provides a larger sample volume with a greater proportion of perilymph compared to sampling through the RW.

  12. Perilymph Sampling from the Cochlear Apex: A Reliable Method to Obtain Higher Purity Perilymph Samples from Scala Tympani

    PubMed Central

    Salt, Alec N.; Hale, Shane A.; Plontke, Stefan K. R.

    2006-01-01

    Measurements of drug levels in the fluids of the inner ear are required to establish kinetic parameters and to determine the influence of specific local delivery protocols. For most substances, this requires cochlear fluids samples to be obtained for analysis. When auditory function is of primary interest, the drug level in the perilymph of scala tympani (ST) is most relevant, since drug in this scala has ready access to the auditory sensory cells. In many prior studies, ST perilymph samples have been obtained from the basal turn, either by aspiration through the round window membrane (RWM) or through an opening in the bony wall. A number of studies have demonstrated that such samples are likely to be contaminated with cerebrospinal fluid (CSF). CSF enters the basal turn of ST through the cochlear aqueduct when the bony capsule is perforated or when fluid is aspirated. The degree of sample contamination has, however, not been widely appreciated. Recent studies have shown that perilymph samples taken through the round window membrane are highly contaminated with CSF, with samples greater than 2 μL in volume containing more CSF than perilymph. In spite of this knowledge, many groups continue to sample from the base of the cochlea, as it is a well-established method. We have developed an alternative, technically simple method to increase the proportion of ST perilymph in a fluid sample. The sample is taken from the apex of the cochlea, a site that is distant from the cochlear aqueduct. A previous problem with sampling through a perforation in the bone was that the native perilymph rapidly leaked out driven by CSF pressure and was lost to the middle ear space. We therefore developed a procedure to collect all the fluid that emerged from the perforated apex after perforation. We evaluated the method using a marker ion trimethylphenylammonium (TMPA). TMPA was applied to the perilymph of guinea pigs either by RW irrigation or by microinjection into the apical turn. The TMPA concentration of the fluid sample was compared with that measured in perilymph prior to taking the sample using a TMPA-selective microelectrode sealed into ST. Data were interpreted with a finite element model of the cochlear fluids that was used to simulate each aspect of the experiment. The correction of sample concentration back to the perilymph concentration prior to sampling can be performed based on the known ST volume (4.7 μL in the guinea pig) and the sample volume. A more precise correction requires some knowledge of the profile of drug distribution along the cochlear prior to sampling. This method of sampling from the apex is technically simple and provides a larger sample volume with a greater proportion of perilymph compared to sampling through the RW. PMID:16310856

  13. Next Generation Programmable Bio-Nano-Chip System for On-Site Detection in Oral Fluids.

    PubMed

    Christodoulides, Nicolaos; De La Garza, Richard; Simmons, Glennon W; McRae, Michael P; Wong, Jorge; Newton, Thomas F; Kosten, Thomas R; Haque, Ahmed; McDevitt, John T

    2015-11-23

    Current on-site drug of abuse detection methods involve invasive sampling of blood and urine specimens, or collection of oral fluid, followed by qualitative screening tests using immunochromatographic cartridges. Test confirmation and quantitative assessment of a presumptive positive are then provided by remote laboratories, an inefficient and costly process decoupled from the initial sampling. Recently, a new noninvasive oral fluid sampling approach that is integrated with the chip-based Programmable Bio-Nano-Chip (p-BNC) platform has been developed for the rapid (~ 10 minutes), sensitive detection (~ ng/ml) and quantitation of 12 drugs of abuse. Furthermore, the system can provide the time-course of select drug and metabolite profiles in oral fluids. For cocaine, we observed three slope components were correlated with cocaine-induced impairment using this chip-based p-BNC detection modality. Thus, this p-BNC has significant potential for roadside drug testing by law enforcement officers. Initial work reported on chip-based drug detection was completed using 'macro' or "chip in the lab" prototypes, that included metal encased "flow cells", external peristaltic pumps and a bench-top analyzer system instrumentation. We now describe the next generation miniaturized analyzer instrumentation along with customized disposables and sampling devices. These tools will offer real-time oral fluid drug monitoring capabilities, to be used for roadside drug testing as well as testing in clinical settings as a non-invasive, quantitative, accurate and sensitive tool to verify patient adherence to treatment.

  14. A gravitational test of wave reinforcement versus fluid density models

    NASA Technical Reports Server (NTRS)

    Johnson, Jacqueline Umstead

    1990-01-01

    Spermatozoa, protozoa, and algae form macroscopic patterns somewhat analogous to thermally driven convection cells. These bioconvective patterns have attracted interest in the fluid dynamics community, but whether in all cases these waves were gravity driven was unknown. There are two conflicting theories, one gravity dependent (fluid density model), the other gravity independent (wave reinforcement theory). The primary objectives of the summer faculty fellows were to: (1) assist in sample collection (spermatozoa) and preparation for the KC-135 research airplane experiment; and (2) to collaborate on ground testing of bioconvective variables such as motility, concentration, morphology, etc., in relation to their macroscopic patterns. Results are very briefly given.

  15. Unique microbial community in drilling fluids from Chinese continental scientific drilling

    USGS Publications Warehouse

    Zhang, Gengxin; Dong, Hailiang; Jiang, Hongchen; Xu, Zhiqin; Eberl, Dennis D.

    2006-01-01

    Circulating drilling fluid is often regarded as a contamination source in investigations of subsurface microbiology. However, it also provides an opportunity to sample geological fluids at depth and to study contained microbial communities. During our study of deep subsurface microbiology of the Chinese Continental Scientific Deep drilling project, we collected 6 drilling fluid samples from a borehole from 2290 to 3350 m below the land surface. Microbial communities in these samples were characterized with cultivation-dependent and -independent techniques. Characterization of 16S rRNA genes indicated that the bacterial clone sequences related to Firmicutes became progressively dominant with increasing depth. Most sequences were related to anaerobic, thermophilic, halophilic or alkaliphilic bacteria. These habitats were consistent with the measured geochemical characteristics of the drilling fluids that have incorporated geological fluids and partly reflected the in-situ conditions. Several clone types were closely related to Thermoanaerobacter ethanolicus, Caldicellulosiruptor lactoaceticus, and Anaerobranca gottschalkii, an anaerobic metal-reducer, an extreme thermophile, and an anaerobic chemoorganotroph, respectively, with an optimal growth temperature of 50–68°C. Seven anaerobic, thermophilic Fe(III)-reducing bacterial isolates were obtained and they were capable of reducing iron oxide and clay minerals to produce siderite, vivianite, and illite. The archaeal diversity was low. Most archaeal sequences were not related to any known cultivated species, but rather to environmental clone sequences recovered from subsurface environments. We infer that the detected microbes were derived from geological fluids at depth and their growth habitats reflected the deep subsurface conditions. These findings have important implications for microbial survival and their ecological functions in the deep subsurface.

  16. The Dutch Pancreas Biobank Within the Parelsnoer Institute: A Nationwide Biobank of Pancreatic and Periampullary Diseases.

    PubMed

    Strijker, Marin; Gerritsen, Arja; van Hilst, Jony; Bijlsma, Maarten F; Bonsing, Bert A; Brosens, Lodewijk A; Bruno, Marco J; van Dam, Ronald M; Dijk, Frederike; van Eijck, Casper H; Farina Sarasqueta, Arantza; Fockens, Paul; Gerhards, Michael F; Groot Koerkamp, Bas; van der Harst, Erwin; de Hingh, Ignace H; van Hooft, Jeanin E; Huysentruyt, Clément J; Kazemier, Geert; Klaase, Joost M; van Laarhoven, Cornelis J; van Laarhoven, Hanneke W; Liem, Mike S; de Meijer, Vincent E; van Rijssen, L Bengt; van Santvoort, Hjalmar C; Suker, Mustafa; Verhagen, Judith H; Verheij, Joanne; Verspaget, Hein W; Wennink, Roos A; Wilmink, Johanna W; Molenaar, I Quintus; Boermeester, Marja A; Busch, Olivier R; Besselink, Marc G

    2018-04-01

    Large biobanks with uniform collection of biomaterials and associated clinical data are essential for translational research. The Netherlands has traditionally been well organized in multicenter clinical research on pancreatic diseases, including the nationwide multidisciplinary Dutch Pancreatic Cancer Group and Dutch Pancreatitis Study Group. To enable high-quality translational research on pancreatic and periampullary diseases, these groups established the Dutch Pancreas Biobank. The Dutch Pancreas Biobank is part of the Parelsnoer Institute and involves all 8 Dutch university medical centers and 5 nonacademic hospitals. Adult patients undergoing pancreatic surgery (all indications) are eligible for inclusion. Preoperative blood samples, tumor tissue from resected specimens, pancreatic cyst fluid, and follow-up blood samples are collected. Clinical parameters are collected in conjunction with the mandatory Dutch Pancreatic Cancer Audit. Between January 2015 and May 2017, 488 patients were included in the first 5 participating centers: 4 university medical centers and 1 nonacademic hospital. Over 2500 samples were collected: 1308 preoperative blood samples, 864 tissue samples, and 366 follow-up blood samples. Prospective collection of biomaterials and associated clinical data has started in the Dutch Pancreas Biobank. Subsequent translational research will aim to improve treatment decisions based on disease characteristics.

  17. A novel method for a fast diagnosis of septic arthritis using mid infrared and deported spectroscopy.

    PubMed

    Albert, Jean-David; Monbet, Valérie; Jolivet-Gougeon, Anne; Fatih, Nadia; Le Corvec, Maëna; Seck, Malik; Charpentier, Frédéric; Coiffier, Guillaume; Boussard-Pledel, Catherine; Bureau, Bruno; Guggenbuhl, Pascal; Loréal, Olivier

    2016-05-01

    To assess the ability of mid infrared deported spectroscopy to discriminate synovial fluids samples of septic arthritis patients from other causes of joint effusion. Synovial fluids obtained from patients with clinically suspected arthritis were collected, analysed and classified according to standard diagnostic procedures as septic or non-septic. A spectroscopic analysis on synovial fluid samples was then performed using a coiled optical fiber made with chalcogenide glass. After a factorial analysis of the normalized spectra and the computation of a Fisher test used to select the most relevant components, a logistic regression model was fitted, allowing to attribute a score between 0 - non-septic -, and 1 - septic. In a first phase, we analysed the synovial fluids from 122 different synovial fluids including 6 septic arthritis among arthritis of various origins. Septic synovial fluids were identified with a sensitivity of 95.8% and a specificity of 93.9% and an AUROC of 0.977. The analysis of an independent set of samples (n=42, including two septic arthritis) gave similar values. Our data strongly supports the interest of mid infrared deported spectroscopy, which could be used potentially at point of care, for a rapid and easy diagnosis of septic arthritis. Now, the precision of the diagnosis must be evaluated through a multicentric study on a larger panel of patients. Copyright © 2015 Société française de rhumatologie. Published by Elsevier SAS. All rights reserved.

  18. Passive cannabis smoke exposure and oral fluid testing. II. Two studies of extreme cannabis smoke exposure in a motor vehicle.

    PubMed

    Niedbala, R Sam; Kardos, Keith W; Fritch, Dean F; Kunsman, Kenneth P; Blum, Kristen A; Newland, Gregory A; Waga, Joe; Kurtz, Lisa; Bronsgeest, Matth; Cone, Edward J

    2005-10-01

    Two studies were conducted to determine if extreme passive exposure to cannabis smoke in a motor vehicle would produce positive results for delta-tetrahydrocannabinol (THC) in oral fluid. Passive exposure to cannabis smoke in an unventilated room has been shown to produce a transient appearance of THC in oral fluid for up to 30 min. However, it is well known that such factors as room size and extent of smoke exposure can affect results. Questions have also been raised concerning the effects of tobacco when mixed with marijuana and THC content. We conducted two passive cannabis studies under severe passive smoke exposure conditions in an unventilated eight-passenger van. Four passive subjects sat alongside four active cannabis smokers who each smoked a single cannabis cigarette containing either 5.4%, 39.5 mg THC (Study 1) or 10.4%, 83.2 mg THC (Study 2). The cigarettes in Study 1 contained tobacco mixed with cannabis; cigarettes in Study 2 contained only cannabis. Oral fluid specimens were collected from passive and active subjects with the Intercept Oral Specimen Collection Device for 1 h after smoking cessation while inside the van (Study 1) and up to 72 h (passive) or 8 h (active) outside the van. Additionally in Study 1, Intercept collectors were exposed to smoke in the van to assess environmental contamination during collection procedures. For Study 2, all oral fluid collections were outside the van following smoking cessation to minimize environmental contamination. Oral samples were analyzed with the Cannabinoids Intercept MICRO-PLATE EIA and quantitatively by gas chromatography-tandem mass spectrometry (GC-MS-MS). THC concentrations were adjusted for dilution (x 3). The screening and confirmation cutoff concentrations for THC in neat oral fluid were 3 ng/mL and 1.5 ng/mL, respectively. The limits of detection (LOD) and quantitation (LOQ) for THC in the GC-MS-MS assay were 0.3 and 0.75 ng/mL, respectively. Urine specimens were collected, screened (EMIT, 50 ng/mL cutoff), and analyzed by GC-MS-MS for THCCOOH (LOD/LOQ = 1.0 ng/mL). Peak oral fluid THC concentrations in passive subjects recorded at the end of cannabis smoke exposure were up to 7.5 ng/mL (Study 1) and 1.2 ng/mL (Study 2). Thereafter, THC concentrations quickly declined to negative levels within 30-45 min in Study 1. It was found that environmentally exposed Collectors contained 3-14 ng/mL in Study 1. When potential contamination during collection was eliminated in Study 2, all passive subjects were negative at screening/confirmation cutoff concentrations throughout the study. Oral fluid specimens from active smokers had peak concentrations of THC approximately 100-fold greater than passive subjects in both studies. Positive oral fluid results were observed for active smokers 0-8 h. Urine analysis confirmed oral fluid results. These studies clarify earlier findings on the effects of passive cannabis smoke on oral fluid results. Oral fluid specimens collected in the presence of cannabis smoke appear to have been contaminated, thereby falsely elevating THC concentrations in oral fluid. The risk of a positive test for THC was virtually eliminated when specimens were collected in the absence of THC smoke.

  19. Elevated levels of numerous cytokines in drainage fluid after primary total hip arthroplasty.

    PubMed

    van der Heide, Huub J L; van der Kraan, Peter M; Rijnberg, Willard J; Buma, Pieter; Schreurs, B Willem

    2010-12-01

    As cytokines are involved in wound healing and other inflammatory processes, it could be valuable to measure their levels at the operative site. This study was conducted to investigate whether different cytokines are measurable in drainage fluid and, when measurable, whether we can find a difference in cytokine levels between one and six hours postoperatively. Samples from the drainage system in 30 consecutive patients undergoing primary total hip replacement were collected at one and six hours after closure of the wound. Levels of several cytokines were measured in the drainage fluids. A significant elevation of almost all cytokines was observed between the sample after one hour and six hours postoperatively. We found a strong correlation between the different pro-inflammatory cytokines. The IL-6 to IL-10 ratio were also raised, showing a pro-inflammatory predominance. Levels were much higher than those previously shown in serum.

  20. [A non-invasive portable blood-glucose monitoring system: sampling of suction effusion fluid].

    PubMed

    Arai, T; Kayashima, S; Kikuchi, M; Kaneyoshi, A; Itoh, N

    1995-04-01

    We developed a new portable transcutaneous blood glucose monitoring system using non-invasive collection of suction effusion fluid (SEF) from human skin. A ion sensitive field effect transistor (ISFET) sensor was employed to measure glucose concentration in a very small quantity of the SEF. The system was composed of a couple of portions. One structure was a suction cell, and the other was a main frame. The suction cell included the ISFET glucose sensor, a dilution mechanism, and a sucking interface to human skin. The main frame contained a dilution solution reservoir, a liquid waste reservoir, a fluid pump, a vacuum pump, a micro processor, batteries, and a user interface. The system is self-contained for portable usage during up to 6 hrs monitoring. This system may be the first blood glucose monitoring equipment which does not use blood sampling.

  1. Reduction of hexavalent chromium by fasted and fed human gastric fluid. I. Chemical reduction and mitigation of mutagenicity.

    PubMed

    De Flora, Silvio; Camoirano, Anna; Micale, Rosanna T; La Maestra, Sebastiano; Savarino, Vincenzo; Zentilin, Patrizia; Marabotto, Elisa; Suh, Mina; Proctor, Deborah M

    2016-09-01

    Evaluation of the reducing capacity of human gastric fluid from healthy individuals, under fasted and fed conditions, is critical for assessing the cancer hazard posed by ingested hexavalent chromium [Cr(VI)] and for developing quantitative physiologically-based pharmacokinetic models used in risk assessment. In the present study, the patterns of Cr(VI) reduction were evaluated in 16 paired pre- and post-meal gastric fluid samples collected from 8 healthy volunteers. Human gastric fluid was effective both in reducing Cr(VI), as measured by using the s-diphenylcarbazide colorimetric method, and in attenuating mutagenicity in the Ames test. The mean (±SE) Cr(VI)-reducing ability of post-meal samples (20.4±2.6μgCr(VI)/mL gastric fluid) was significantly higher than that of pre-meal samples (10.2±2.3μgCr(VI)/mL gastric fluid). When using the mutagenicity assay, the decrease of mutagenicity produced by pre-meal and post-meal samples corresponded to reduction of 13.3±1.9 and 25.6±2.8μgCr(VI)/mL gastric fluid, respectively. These data are comparable to parallel results conducted by using speciated isotope dilution mass spectrometry. Cr(VI) reduction was rapid, with >70% of total reduction occurring within 1min and 98% of reduction is achieved within 30min with post-meal gastric fluid at pH2.0. pH dependence was observed with decreasing Cr(VI) reducing capacity at higher pH. Attenuation of the mutagenic response is consistent with the lack of DNA damage observed in the gastrointestinal tract of rodents following administration of ≤180ppm Cr(VI) for up to 90days in drinking water. Quantifying Cr(VI) reduction kinetics in the human gastrointestinal tract is necessary for assessing the potential hazards posed by Cr(VI) in drinking water. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.

  2. Utility of Cytospin and Cell block Technology in Evaluation of Body Fluids and Urine Samples: A Comparative Study

    PubMed Central

    Qamar, Irmeen; Rehman, Suhailur; Mehdi, Ghazala; Maheshwari, Veena; Ansari, Hena A.; Chauhan, Sunanda

    2018-01-01

    Background: Cytologic examination of body fluids commonly involves the use of direct or sediment smears, cytocentrifuge preparations, membrane filter preparations, or cell block sections. Cytospin and cell block techniques are extremely useful in improving cell yield of thin serous effusions and urine samples, and ensure high diagnostic efficacy. Materials and Methods: We studied cytospin preparations and cell block sections prepared from 180 samples of body fluids and urine samples to compare the relative efficiency of cell retrieval, preservation of cell morphology, ease of application of special stains, and diagnostic efficacy. Samples were collected and processed to prepare cytospin smears and cell block sections. Results: We observed that overall, cell yield and preservation of individual cell morphology were better in cytospin preparations as compared to cell blocks, while preservation of architectural pattern was better in cell block sections. The number of suspicious cases also decreased on cell block sections, with increased detection of malignancy. It was difficult to prepare cell blocks from urine samples due to low cellularity. Conclusions: Cytospin technology is a quick, efficient, and cost-effective method of increasing cell yield in hypocellular samples, with better preservation of cell morphology. Cell blocks are better prepared from high cellularity fluids; however, tissue architecture is better studied, with improved rate of diagnosis and decrease in ambiguous results. Numerous sections can be prepared from a small amount of material. Special stains and immunochemical stains can be easily applied to cell blocks. It also provides a source of archival material. PMID:29643653

  3. Angiotensinogen concentration in the cerebrospinal fluid in different experimental conditions in the rat.

    PubMed

    Ruiz, P; Basso, N; Grinspon, D; Mangiarua, E; Cannata, M A

    1983-01-01

    Angiotensinogen is the most important component of the renin-angiotensin system present in the cerebrospinal fluid (CSF) of the rat. Its physiological significance as well as its origin have not been clearly elucidated. In this experiment we have examined plasma renin activity (PRA) and plasma and CSF angiotensinogen concentration under the following experimental conditions in male rats of the Wistar strain: 1) adrenalectomy (Adx) 4 days prior to sample collection; controls were sham Adx animals; 2) nephrectomy (Nx) 48 hours before blood and CSF collection; controls were sham Nx rats; 3) DOC-salt treatment (Cortexon depot, 50 mg/kg.s.c. twice a week) plus saline to drink was given during 4 weeks; controls were intact rats; 4) DOC-salt plus captopril: captopril (100 mg/kg/day) in the drinking fluid was added to the treatment of experimental and control animals of Group 3; 5) two-kidney, two clip hypertension: silver clips placed in both renal arteries 8 weeks before samples collection; control: sham-operated rats; 6) water deprivation: rats deprived of water for 5 days; controls: intact rats; 7) peripheral sympathectomy: 6-hydroxydopamine (6-HODA) injected s.c. from birth until 16 weeks of age, adrenodemedullectomy and adrenal denervation performed at 8 weeks; controls were vehicle-injected animals. Determination of angiotensinogen concentration in plasma and CSF was accomplished by incubation of the samples with excess hog renin. The angiotensin I released as well as PRA were evaluated using an specific radioimmunoassay technique. PRA was significantly increased by Adx, captopril treatment, and water deprivation, and was almost suppressed by Nx, DOC-salt, and DOC-salt plus captopril treatment.(ABSTRACT TRUNCATED AT 250 WORDS)

  4. Vaginal Prostate Specific Antigen (PSA) Is a Useful Biomarker of Semen Exposure Among HIV-Infected Ugandan Women.

    PubMed

    Woolf-King, Sarah E; Muyindike, Winnie; Hobbs, Marcia M; Kusasira, Adrine; Fatch, Robin; Emenyonu, Nneka; Johnson, Mallory O; Hahn, Judith A

    2017-07-01

    The practical feasibility of using prostate specific antigen (PSA) as a biomarker of semen exposure was examined among HIV-infected Ugandan women. Vaginal fluids were obtained with self-collected swabs and a qualitative rapid test (ABAcard ® p30) was used to detect PSA. Trained laboratory technicians processed samples on-site and positive PSA tests were compared to self-reported unprotected vaginal sex (UVS) in the last 48 h. A total of 77 women submitted 126 samples for PSA testing at up to three study visits. Of these samples, 31 % (n = 39/126) were PSA positive, and 64 % (n = 25/39) of the positive PSA samples were accompanied by self-report of no UVS at the study visit the PSA was collected. There were no reported difficulties with specimen collection, storage, or processing. These findings provide preliminary data on high levels of misreported UVS among HIV-infected Ugandan women using practically feasible methods for PSA collection and processing.

  5. Influence of pollution control on lead inhalation bioaccessibility in PM2.5: A case study of 2014 Youth Olympic Games in Nanjing.

    PubMed

    Li, Shi-Wei; Li, Hong-Bo; Luo, Jun; Li, Hui-Ming; Qian, Xin; Liu, Miao-Miao; Bi, Jun; Cui, Xin-Yi; Ma, Lena Q

    2016-09-01

    Pollution controls were implemented to improve the air quality for the 2014 Youth Olympic Games (YOG) in Nanjing. To investigate the influence of pollution control on Pb inhalation bioaccessibility in PM2.5, samples were collected before, during, and after YOG. The objectives were to identify Pb sources in PM2.5 using stable isotope fingerprinting technique and compare Pb inhalation bioaccessibility in PM2.5 using two simulated lung fluids. While artificial lysosomal fluid (ALF) simulates interstitial fluid at pH 7.4, Gamble's solution simulates fluid in alveolar macrophages at pH 4.5. The Pb concentration in PM2.5 samples during YOG (88.2ngm(-3)) was 44-48% lower than that in non-YOG samples. Based on stable Pb isotope ratios, Pb in YOG samples was mainly from coal combustion while Pb in non-YOG samples was from coal combustion and smelting activities. While Pb bioaccessibility in YOG samples was lower than those in non-YOG samples (59-79% vs. 55-87%) by ALF, it was higher than those in non-YOG samples (11-29% vs. 5.3-21%) based on Gamble's solution, attributing to the lower pH and organic acids in ALF. Different Pb bioaccessibility in PM2.5 between samples resulted from changes in Pb species due to pollution control. PbSO4 was the main Pb species in PM2.5 from coal combustion, which was less soluble in ALF than PbO from smelting activities, but more soluble in Gamble's solution. This study showed it is important to consider Pb bioaccessibility during pollution control as source control not only reduced Pb contamination in PM2.5 but also influenced Pb bioaccessibility. Published by Elsevier Ltd.

  6. Current Knowledge on Cannabinoids in Oral Fluid

    PubMed Central

    Lee, Dayong; Huestis, Marilyn A.

    2015-01-01

    Oral fluid (OF) is a new biological matrix for clinical and forensic drug testing, offering non-invasive and directly observable sample collection reducing adulteration potential, ease of multiple sample collections, lower biohazard risk during collection, recent exposure identification, and stronger correlation with blood than urine concentrations. Because cannabinoids are usually the most prevalent analytes in illicit drug testing, application of OF drug testing requires sufficient scientific data to support sensitive and specific OF cannabinoid detection. This review presents current knowledge on OF cannabinoids, evaluating pharmacokinetic properties, detection windows, and correlation with other biological matrices and impairment from field applications and controlled drug administration studies. In addition, on-site screening technologies, confirmatory analytical methods, drug stability, and effects of sample collection procedure, adulterants, and passive environmental exposure are reviewed. Delta-9-tetrahydrocannabinol OF concentrations could be > 1000 μg/L shortly after smoking, whereas minor cannabinoids are detected at 10-fold and metabolites at 1000-fold lower concentrations. OF research over the past decade demonstrated that appropriate interpretation of test results requires a comprehensive understanding of distinct elimination profiles and detection windows for different cannabinoids, which are influenced by administration route, dose, and drug use history. Thus, each drug testing program should establish cutoff criteria, collection/analysis procedures, and storage conditions tailored to its purposes. Building a scientific basis for OF testing is on-going, with continuing OF cannabinoids research on passive environmental exposure, drug use history, donor physiological conditions, and oral cavity metabolism needed to better understand mechanisms of cannabinoid OF disposition and expand OF drug testing applicability. PMID:23983217

  7. The Role Of Staphylococcus Haemolyticus In Men Infertility

    NASA Astrophysics Data System (ADS)

    AL-Ghizzawi, Ghaed’a. J.; Jomaa, Zahraa K.

    2018-05-01

    A total of 80 samples of seminal fluid from infertile men who were admitted to clinics and attended laboratories in Omara City during the period from 1 June 2016 to 1 December 2016, samples were subjected to semen analysis as recommended by WHO. The age of patients was from 20 – 59 year. Another 25 semen samples were collected from fertilized men considered as the control group. For this purpose seminal fluid were cultured on MacConkey agar, Blood agar, Chocolate agar. Within the 80 samples recorded S. haemolyticus appeared in 14 cases and the rate of infection was 18%, all strains was diagnosed by Vitek system 2 Double. The highest percent (64%) was recorded in the age group 30 – 39. Primary infertility recorded 94% while 6% was recorded for secondary infertility. Also, different species of bacterial isolates were identified in 32 cases by Vitek system 2 Double. The bacterial infection of the male genital system affected fertility.

  8. Triple Pancreatic Walled-off Fluid Collections Treated Simultaneously with Endoscopic Transmural Drainage.

    PubMed

    Khalid, Sameen; Abbass, Aamer; Nellis, Eric; Shah, Shashin; Shah, Hiral

    2018-01-09

    Pancreatic pseudocysts and walled-off pancreatic necrosis arise as a complication of pancreatitis. Multiple fluid collections are seen in 5-20% of the patients who have walled-off peripancreatic fluid collections. There is a paucity of data regarding the role of endoscopic transmural drainage in the management of multiple pancreatic fluid collections. In this case report, we present the case of a 72-year-old male with three walled-off pancreatic fluid collections in the setting of acute necrotizing pancreatitis. The patient underwent simultaneous endoscopic ultrasound-assisted cyst gastrostomy and cyst duodenostomy and aggressive irrigation without index endoscopic necrosectomy of the three peripancreatic fluid collections. Significant improvement in the size of the fluid collections was seen on the computed tomography scan, as well as a remarkable immediate clinical improvement after 24 hours of the endoscopic intervention.

  9. Headspace screening of fluid obtained from the gut during colonoscopy and breath analysis by proton transfer reaction-mass spectrometry: A novel approach in the diagnosis of gastro-intestinal diseases

    NASA Astrophysics Data System (ADS)

    Lechner, M.; Colvin, H. P.; Ginzel, C.; Lirk, P.; Rieder, J.; Tilg, H.

    2005-05-01

    Background: The diagnosis of many gastro-intestinal diseases is difficult and can often be confirmed only by using invasive diagnostic means. In contrast, the headspace screening of fluid obtained from the gut during colonoscopy and the analysis of exhaled air may be a novel approach for the diagnosis of these diseases.Materials and methods: The screening was performed by using proton transfer reaction-mass spectrometry (PTR-MS) which allows rapid and sensitive measurement. Fluid samples obtained from the gut during colonoscopy were collected from 76 and breath samples from 70 subjects. Mass spectra of healthy controls were created. Afterwards these spectra were compared with those of patients suffering from inflammatory bowel diseases (IBD; Crohn's disease and ulcerative colitis; n = 10) and irritable bowel syndrome (IBS; n = 7).Results: Significant differences in the mass spectra could be observed both in the headspace of the fluid and in the exhaled air comparing patients with healthy controls.Conclusions: This study is the first describing headspace screening of fluid obtained from the gut during colonoscopy, possibly presenting a novel diagnostic tool in the differential diagnosis of gastro-intestinal diseases.

  10. New strategy for the survey of Toxoplasma gondii in meat for human consumption.

    PubMed

    Villena, Isabelle; Durand, Benoit; Aubert, Dominique; Blaga, Radu; Geers, Régine; Thomas, Myriam; Perret, Catherine; Alliot, Annie; Escotte-Binet, Sandie; Thébault, Anne; Boireau, Pascal; Halos, Lénaïg

    2012-02-10

    Monitoring of Toxoplasma infection in animals destined for human consumption is a great challenge for human toxoplasmosis prevention. This study aimed to compare results obtained from a naturally infected population of sheep using different tests and targeting an original matrix: meat samples and muscle fluids collected at the slaughterhouse. A commercial ELISA test was performed on diaphragm fluids from 419 ovine carcasses collected at the slaughterhouse. A MAT (modified agglutination test) was performed on heart fluids obtained from the same animals. In addition, all hearts were bioassayed in mice. Serological test agreement, the relative sensitivity of ELISA MAT and mouse bioassay as well as a correlation between titres and parasite isolation probability were statistically evaluated. The overall agreement (kappa coefficient=0.64) of ELISA on diaphragm fluids and MAT on heart fluids is substantial and subsequently both tests can be used for epidemiological studies. Relative sensitivity was higher for MAT performed on cardiac fluids (90%) than ELISA on diaphragm fluid (61%). For both serological tests, relative sensitivity is lower in lambs younger than 12 months. Relative sensitivity of mouse inoculation was 42%. A significant correlation was obtained between increasing MAT titres and probability to isolate live parasite from the heart. When the fluid titre was higher than 1:16, parasites were isolated in 65% of cases. When it was lower, isolation failed in 95% of the cases. According to our results, cardiac fluids appear to be a relevant matrix for toxoplasmosis survey in meat. Copyright © 2011 Elsevier B.V. All rights reserved.

  11. Impact of Oral Fluid Collection Device on Cannabinoid Stability Following Smoked Cannabis

    PubMed Central

    Anizan, Sébastien; Bergamaschi, Mateus M.; Barnes, Allan J.; Milman, Garry; Desrosiers, Nathalie; Lee, Dayong; Gorelick, David A.; Huestis, Marilyn A.

    2014-01-01

    Evaluation of cannabinoid stability in authentic oral fluid (OF) is critical, as most OF stability studies employed fortified or synthetic OF. Participants (n=16) smoked a 6.8% delta-9-tetrahydrocannabinol (THC) cigarette, and baseline concentrations of THC, 11-nor-9-carboxy-THC (THCCOOH), cannabidiol (CBD), and cannabinol (CBN) were determined within 24h in 16 separate pooled samples (collected 1h before to 10.5 or 13h after smoking). OF was collected with the StatSure Saliva Sampler™ and Oral-Eze® devices. Oral-Eze samples were re-analyzed after room temperature (RT) storage for 1 week, and for both devices after 4°C for 1 and 4 weeks, and –20°C for 4 and 24 weeks. Concentrations ±20% from initial concentrations were considered stable. With the StatSure device, all cannabinoids were within 80-120% median %baseline for all storage conditions. Individual THC, CBD, CBN and THCCOOH pool concentrations were stable in 100%, 100%, 80-94% and >85%, respectively, across storage conditions. With the Oral-Eze device, at RT or refrigerated storage (for 1 and 4 weeks), THC, CBD and THCCOOH were stable in 94-100%, 78-89% and 93-100% of samples, respectively, while CBN concentrations were 53–79% stable. However, after 24 weeks at -20°C, stability decreased, especially for CBD, with a median of 56% stability. Overall, the collection devices’ elution/stabilizing buffers provided good stability for OF cannabinoids, with the exception of the more labile CBN. To ensure OF cannabinoid concentration accuracy, these data suggest analysis within 4 weeks at 4°C storage for Oral-Eze collection and within 4 weeks at 4°C or 24 weeks at -20°C for StatSure collection. PMID:24995604

  12. Illicit Drugs in Oral Fluid: Evaluation of Two Collection Devices.

    PubMed

    Cohier, Camille; Mégarbane, Bruno; Roussel, Olivier

    2017-01-01

    Driving after illicit drug use is a worldwide growing concern requiring rapid and sensitive screening at the roadside. It is noteworthy that the sampling method used to collect oral fluid (OF) may significantly influence drug concentrations in the collected sample and thus alter the accuracy of the measurement. We evaluated two OF collection devices, Quantisal ® and Certus ® collectors, for their suitability for collecting samples to allow laboratory confirmation of driving after illicit drug use. Four parameters were studied including (i) the collected OF volume; (ii) the recovery efficiency using OFs spiked with opiates, cannabinoids, amphetamines, cocaine and its metabolites; (iii) drug stability after storage for 1, 7 and 14 days at -20°C, +4°C and room temperature; and (iv) the impact of mouth cells present in the collected OF on drug stability. Drug concentrations were measured using gas and liquid chromatography-mass spectrometry. Certus ® collector allowed the collection of significantly larger (0.94 ± 0.18 mL vs. 0.84 ± 0.06 mL, P = 0.08) but less reproducible OF volumes (19 vs. 6.7%) compared with Quantisal ® collector. Drug recovery was significantly better with Quantisal ® than with Certus ® collector, especially when used to detect cannabinoids (0.94 vs. 0.54, P < 0.001 for ∆9-tetrahydrocannabinol (THC)). For both OF collectors, storage at 4°C was preferable except for methadone, the stability of which was altered by adherence to the collector device. In the presence of mouth cells in the OF sample, THC concentrations were significantly decreased at Day 7 in comparison with Day 1 with both collection devices (P = 0.001 with Quantisal ® collector and P = 0.01 with Certus ® collector). In conclusion, Quantisal ® collector is more reliable than Certus ® collector although the practicability of both devices remains to be determined at the roadside. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  13. Food and fluid intake of the SENECA population residing in Romans, France.

    PubMed

    Ferry, M; Hininger-Favier, I; Sidobre, B; Mathey, M F

    2001-01-01

    to provide information and data on food and fluid intake of free-living elderly aged of 81-86 years old residing in the south of France. using standardised methods data were collected from a random sample born between 1913 and 1918. The French study protocol again included data collection on dietary intake using a standardised modified dietary history consisting of a food frequency list and a 3-day estimated dietary record. Total dietary intake was generally low as compared to the recommended daily intake for elderly subjects. This descriptive part of the SENECA study gives the opportunity to have information on this growing segment of the population. These results should help to adapt the dietary guidelines for this category of the population.

  14. Situ soil sampling probe system with heated transfer line

    DOEpatents

    Robbat, Jr., Albert

    2002-01-01

    The present invention is directed both to an improved in situ penetrometer probe and to a heated, flexible transfer line. The line and probe may be implemented together in a penetrometer system in which the transfer line is used to connect the probe to a collector/analyzer at the surface. The probe comprises a heater that controls a temperature of a geologic medium surrounding the probe. At least one carrier gas port and vapor collection port are located on an external side wall of the probe. The carrier gas port provides a carrier gas into the geologic medium, and the collection port captures vapors from the geologic medium for analysis. In the transfer line, a flexible collection line that conveys a collected fluid, i.e., vapor, sample to a collector/analyzer. A flexible carrier gas line conveys a carrier gas to facilitate the collection of the sample. A system heating the collection line is also provided. Preferably the collection line is electrically conductive so that an electrical power source can generate a current through it so that the internal resistance generates heat.

  15. Antibody Protein Array Analysis of the Tear Film Cytokines

    PubMed Central

    Li, Shimin; Sack, Robert; Vijmasi, Trinka; Sathe, Sonal; Beaton, Ann; Quigley, David; Gallup, Marianne; McNamara, Nancy A.

    2013-01-01

    Purpose Many bioactive proteins including cytokines are reported to increase in dry eye disease although the specific profile and concentration of inflammatory mediators varies considerably from study to study. In part this variability results from inherent difficulties in quantifying low abundance proteins in a limited sample volume using relatively low sensitivity dot ELISA methods. Additional complexity comes with the use of pooled samples collected using a variety of techniques and intrinsic variation in the diurnal pattern of individual tear proteins. The current study describes a recent advance in the area of proteomics that has allowed the identification of dozens of low abundance proteins in human tear samples. Methods Commercially available stationary phase antibody protein arrays were adapted to improve suitability for use in small volume biological fluid analysis with particular emphasis on tear film proteomics. Arrays were adapted to allow simultaneous screening for a panel of inflammatory cytokines in low volume tear samples collected from individual eyes. Results A preliminary study comparing tear array results in a small population of Sjögren’s syndrome patients was conducted. The multiplex microplate array assays of cytokines in tear fluid present an unanticipated challenge due to the unique nature of tear fluid. The presence of factors that exhibit an affinity for plastic, capture antibodies and IgG and create a complex series of matrix effects profoundly impacting the reliability of dot ELISA, including with elevated levels of background reactivity and reduction in capacity to bind targeted protein. Conclusions Preliminary results using tears collected from patients with Sjögren’s syndrome reveal methodological advantages of protein array technology and support the concept that autoimmune-mediated dry eye disease has an inflammatory component. They also emphasize the inherent difficulties one can face when interpreting the results of micro-well arrays that result from blooming effects, matrix effects, image saturation and cross-talk between capture and probe antibodies that can greatly reduce signal-to-noise and limit the ability to obtain meaningful results. PMID:18677223

  16. Inorganic chemical composition and chemical reactivity of settled dust generated by the World Trade Center building collapse: Chapter 12

    USGS Publications Warehouse

    Plumlee, Geoffrey S.; Hageman, Philip L.; Lamothe, Paul J.; Ziegler, Thomas L.; Meeker, Gregory P.; Theodorakos, Peter M.; Brownfield, Isabelle; Adams, Monique G.; Swayze, Gregg A.; Hoefen, Todd M.; Taggart, Joseph E.; Clark, Roger N.; Wilson, S.; Sutley, Stephen J.

    2009-01-01

    Samples of dust deposited around lower Manhattan by the September 11, 2001, World Trade Center (WTC) collapse have inorganic chemical compositions that result in part from the variable chemical contributions of concrete, gypsum wallboard, glass fibers, window glass, and other materials contained in the buildings. The dust deposits were also modified chemically by variable interactions with rain water or water used in street washing and fire fighting. Chemical leach tests using deionized water as the extraction fluid show the dust samples can be quite alkaline, due primarily to reactions with calcium hydroxide in concrete particles. Calcium and sulfate are the most soluble components in the dust, but many other elements are also readily leached, including metals such as Al, Sb, Mo Cr, Cu, and Zn. Indoor dust samples produce leachates with higher pH, alkalinity, and dissolved solids than outdoor dust samples, suggesting most outdoor dust had reacted with water and atmospheric carbon dioxide prior to sample collection. Leach tests using simulated lung fluids as the extracting fluid suggest that the dust might also be quite reactive in fluids lining the respiratory tract, resulting in dissolution of some particles and possible precipitation of new phases such as phosphates, carbonates, and silicates. Results of these chemical characterization studies can be used by health scientists as they continue to track and interpret health effects resulting from the short-term exposure to the initial dust cloud and the longer-term exposure to dusts resuspended during cleanup.

  17. Systems and methods for separating particles and/or substances from a sample fluid

    DOEpatents

    Mariella, Jr., Raymond P.; Dougherty, George M.; Dzenitis, John M.; Miles, Robin R.; Clague, David S.

    2016-11-01

    Systems and methods for separating particles and/or toxins from a sample fluid. A method according to one embodiment comprises simultaneously passing a sample fluid and a buffer fluid through a chamber such that a fluidic interface is formed between the sample fluid and the buffer fluid as the fluids pass through the chamber, the sample fluid having particles of interest therein; applying a force to the fluids for urging the particles of interest to pass through the interface into the buffer fluid; and substantially separating the buffer fluid from the sample fluid.

  18. Analysis of serum and cerebrospinal fluid in clinically normal adult miniature donkeys.

    PubMed

    Mozaffari, A A; Samadieh, H

    2013-09-01

    To establish reference intervals for serum and cerebrospinal fluid (CSF) parameters in clinically healthy adult miniature donkeys. Experiments were conducted on 10 female and 10 male clinically normal adult miniature donkeys, randomly selected from five herds. Lumbosacral CSF collection was performed with the sedated donkey in the standing position. Cell analysis was performed immediately after the samples were collected. Blood samples were obtained from the jugular vein immediately after CSF sample collection. Sodium, potassium, glucose, urea nitrogen, total protein, calcium, chloride, phosphorous and magnesium concentrations were measured in CSF and serum samples. A paired t-test was used to compare mean values between female and male donkeys. The CSF was uniformly clear, colourless and free from flocculent material, with a specific gravity of 1.002. The range of total nucleated cell counts was 2-4 cells/μL. The differential white cell count comprised only small lymphocytes. No erythrocytes or polymorphonuclear cells were observed on cytological examination. Reference values were obtained for biochemical analysis of serum and CSF. Gender had no effect on any variables measured in serum or CSF (p>0.05). CSF analysis can provide important information in addition to that gained by clinical examination. CSF analysis has not previously been performed in miniature donkeys; this is the first report on the subject. In the present study, reference intervals for total nucleated cell count, total protein, glucose, urea nitrogen, sodium, potassium, chloride, calcium, phosphorous and magnesium concentrations of serum and CSF were determined for male and female miniature donkeys.

  19. Rock Geochemistry and Mineralogy from Fault Zones and Polymetallic Fault Veins of the Central Front Range, Colorado

    USGS Publications Warehouse

    Caine, Jonathan S.; Bove, Dana J.

    2010-01-01

    During the 2004 to 2008 field seasons, approximately 200 hand samples of fault and polymetallic vein-related rocks were collected for geochemical and mineralogical analyses. The samples were collected by the U.S. Geological Survey as part of the Evolution of Brittle Structures Task under the Central Colorado Assessment Project (CCAP) of the Mineral Resources Program (http://minerals.cr.usgs.gov/projects/colorado_assessment/index.html). The purpose of this work has been to characterize the relation between epithermal, polymetallic mineral deposits, paleostress, and the geological structures that hosted fluid flow and localization of the deposits. The data in this report will be used to document and better understand the processes that control epithermal mineral-deposit formation by attempting to relate the geochemistry of the primary structures that hosted hydrothermal fluid flow to their heat and fluid sources. This includes processes from the scale of the structures themselves to the far field scale, inclusive of the intrusive bodies that have been thought to be the sources for the hydrothermal fluid flow. The data presented in this report are part of a larger assessment effort on public lands. The larger study area spans the region of the southern Rocky Mountains in Colorado from the Wyoming to New Mexico borders and from the eastern boundary of the Front Range to approximately the longitude of Vail and Leadville, Colorado. Although the study area has had an extensive history of geological mapping, the mapping has resulted in a number of hypotheses that are still in their infancy of being tested. For example, the proximity of polymetallic veins to intrusive bodies has been thought to reflect a genetic relation between the two features; however, this idea has not been well tested with geochemical indicators. Recent knowledge regarding the coupled nature of stress, strain, fluid flow, and geochemistry warrant new investigations and approaches to test a variety of ideas regarding the genetic processes associated with ore-deposit formation. The central part of the eastern Front Range has excellent exposures of fault zones and polymetallic fault veins, subsequently resulting in some of the most detailed mapping and associated data sets in the region. Thus, the area was chosen for detailed data compilation, new sample and data collection, and a variety of structural and geochemical analyses. The data presented in this report come from samples of fault-related exposures in the Front Range and include elemental chemistry and mineralogy from the outcrop-scale study localities within the larger CCAP study area.

  20. Association of digital cushion thickness with sole temperature measured with the use of infrared thermography.

    PubMed

    Oikonomou, G; Trojacanec, P; Ganda, E K; Bicalho, M L S; Bicalho, R C

    2014-07-01

    The main objective of this study was to investigate the association between digital cushion thickness and sole temperature measured by infrared thermography. Data were collected from 216 lactating Holstein cows at 4 to 10d in milk (DIM). Cows were locomotion scored and sole temperature was measured after claw trimming (a minimum delay of 3 min was allowed for the hoof to cool) using an infrared thermography camera. Temperature was measured at the typical ulcer site of the lateral digit of the left hind foot. Immediately after the thermographic image was obtained, the thickness of the digital cushion was measured by ultrasonography. Rumen fluid samples were collected with a stomach tube and sample pH was measured immediately after collection. Additionally, a blood sample was obtained and used for measurements of serum concentrations of β-hydroxybutyrate (BHBA), nonesterified fatty acids (NEFA), and haptoglobin. To evaluate the associations of digital cushion thickness with sole temperature, a linear regression model was built using the GLIMMIX procedure in SAS software (SAS Institute Inc., Cary, NC). Sole temperature was the response variable, and digital cushion thickness quartiles, locomotion score group, rumen fluid pH, rumen fluid sample volume, environmental temperature, age in days, and serum levels of NEFA, BHBA, and haptoglobin were fitted in the model. Only significant variables were retained in the final model. Simple linear regression scatter plots were used to illustrate associations between sole temperature (measured by infrared thermography at the typical ulcer site) and environmental temperature and between NEFA and BHBA serum levels and haptoglobin. One-way ANOVA was used to compare rumen fluid pH for different locomotion score groups and for different digital cushion quartiles. Results from the multivariable linear regression model showed that sole temperature increased as locomotion scores increased and decreased as digital cushion thickness increased. These results were adjusted for environmental temperature, which was significantly associated with sole temperature. Serum levels of NEFA, BHBA, and haptoglobin were not associated with sole temperature. However, significant correlations existed between serum levels of NEFA and haptoglobin and between serum levels of BHBA and haptoglobin. Rumen fluid pH was not associated with either locomotion score or digital cushion thickness. In conclusion, we show here that digital cushion thickness was associated with sole temperature in cows at 4 to 10 DIM. Copyright © 2014 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  1. Diagnosis of ocular toxoplasmosis by two polymerase chain reaction (PCR) examinations: qualitative multiplex and quantitative real-time.

    PubMed

    Sugita, Sunao; Ogawa, Manabu; Inoue, Shizu; Shimizu, Norio; Mochizuki, Manabu

    2011-09-01

    To establish a two-step polymerase chain reaction (PCR) diagnostic system for ocular toxoplasmosis. A total of 13 ocular fluid samples (11 aqueous humor and 2 vitreous fluid) were collected from 13 patients with clinically suspected ocular toxoplasmosis. Ten ocular samples from other uveitis patients and 20 samples from subjects without ocular inflammation were used as controls. Two polymerase chain reaction (PCR) methods, i.e., qualitative multiplex PCR and quantitative real-time PCR, were used to measure the toxoplasma genome (T. gondii B1 gene). Qualitative multiplex PCR detected T. gondii B1 gene in the ocular fluids of 11 out of 13 patients with clinically suspected ocular toxoplasmosis. In real-time PCR, we detected high copy numbers of T. gondii DNA (5.1 × 10(2)-2.1 × 10(6) copies/mL) in a total of 10 patients (10/13, 77%). Only ocular toxoplasmosis scar lesions were observed in the three real-time PCR-negative patients. PCR assay results for the samples from the two control groups were all negative. The two-step PCR examination to detect toxoplasma DNA is a useful tool for diagnosing ocular toxoplasmosis.

  2. Report to DHS on Summer Internship 2006

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Beckwith, R H

    2006-07-26

    This summer I worked at Lawrence Livermore National Laboratory in a bioforensics collection and extraction research group under David Camp. The group is involved with researching efficiencies of various methods for collecting bioforensic evidence from crime scenes. The different methods under examination are a wipe, swab, HVAC filter and a vacuum. The vacuum is something that has particularly gone uncharacterized. My time was spent mostly on modeling and calculations work, but at the end of the summer I completed my internship with a few experiments to supplement my calculations. I had two major projects this summer. My first major projectmore » this summer involved fluid mechanics modeling of collection and extraction situations. This work examines different fluid dynamic models for the case of a micron spore attached to a fiber. The second project I was involved with was a statistical analysis of the different sampling techniques.« less

  3. Prescription and illicit psychoactive drugs in oral fluid--LC-MS/MS method development and analysis of samples from Brazilian drivers.

    PubMed

    Zancanaro, Ivomar; Limberger, Renata Pereira; Bohel, Paula O; dos Santos, Maíra Kerpel; De Boni, Raquel B; Pechansky, Flavio; Caldas, Eloisa Dutra

    2012-11-30

    This study is part of a larger project designed to investigate the prevalence of psychoactive drug (PAD) use among Brazilian drivers. In this paper we describe the development and validation of an analytical method to analyze 32 prescription and illicit PADs (amphetamines, benzodiazepines, cocaine, cannabis, opioids, ketamine and m-CPP) and metabolites in oral fluid samples collected with a Quantisal™ device. Samples were extracted with ethyl acetate:hexane and analyzed by LC-MS/MS. Instrumental LOD ranged from 0.26 to 0.65 ng/mL. Mean procedural recoveries at 1.3 ng/mL (LLOQ) ranged from 50% to 120% for 24 compounds. Recoveries were concentration independent, with the exception of femproporex, heroin and ecgonine methyl-ester (EME) for which the recovery decreased significantly at higher levels (13 and 52 ng/mL). RSD was <20% for all compounds at all spiking levels. Ion suppression due to the matrix was <20% for most compounds, and higher than 60% for EME and diethylpropion. Analysis was performed against a in-matrix standard curve. About 10% of the 2235 oral fluid samples collected from drivers on Brazilian Federal highways were positive (≥LOD) for at least one analyte investigated. Alone or in combination with other drugs, cocaine/metabolites were the analytes most detected in the samples (129; 5.8%), followed by amphetamines/metabolite (69; 3.1%), benzodiazepines (28; 1.2%), cannabinoids (23; 1.1%) and opioids (8; 0.4%). Detection of at least two PADs from different classes accounted for 9.3% of the 236 positive samples. Cocaine was found at higher levels in the samples (up to 1165 ng/mL). Preventive measures aimed at reducing the use of PADs by drivers in Brazil will certainly contribute to decrease the country's highway death rates. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  4. Comparison of the diagnostic performance of bacterial culture of nasopharyngeal swab and bronchoalveolar lavage fluid samples obtained from calves with bovine respiratory disease.

    PubMed

    Capik, Sarah F; White, Brad J; Lubbers, Brian V; Apley, Michael D; DeDonder, Keith D; Larson, Robert L; Harhay, Greg P; Chitko-McKown, Carol G; Harhay, Dayna M; Kalbfleisch, Ted S; Schuller, Gennie; Clawson, Michael L

    2017-03-01

    OBJECTIVE To compare predictive values, extent of agreement, and gamithromycin susceptibility between bacterial culture results of nasopharyngeal swab (NPS) and bronchoalveolar lavage fluid (BALF) samples obtained from calves with bovine respiratory disease (BRD). ANIMALS 28 beef calves with clinical BRD. PROCEDURES Pooled bilateral NPS samples and BALF samples were obtained for bacterial culture from calves immediately before and at various times during the 5 days after gamithromycin (6 mg/kg, SC, once) administration. For each culture-positive sample, up to 12 Mannheimia haemolytica, 6 Pasteurella multocida, and 6 Histophilus somni colonies underwent gamithromycin susceptibility testing. Whole-genome sequencing was performed on all M haemolytica isolates. For paired NPS and BALF samples collected 5 days after gamithromycin administration, the positive and negative predictive values for culture results of NPS samples relative to those of BALF samples and the extent of agreement between the sampling methods were determined. RESULTS Positive and negative predictive values of NPS samples were 67% and 100% for M haemolytica, 75% and 100% for P multocida, and 100% and 96% for H somni. Extent of agreement between results for NPS and BALF samples was substantial for M haemolytica (κ, 0.71) and H somni (κ, 0.78) and almost perfect for P multocida (κ, 0.81). Gamithromycin susceptibility varied within the same sample and between paired NPS and BALF samples. CONCLUSIONS AND CLINICAL RELEVANCE Results indicated culture results of NPS and BALF samples from calves with BRD should be interpreted cautiously considering disease prevalence within the population, sample collection relative to antimicrobial administration, and limitations of diagnostic testing methods.

  5. Incidence, risk factors and clinical course of pancreatic fluid collections in acute pancreatitis.

    PubMed

    Cui, Mei Lan; Kim, Kook Hyun; Kim, Ho Gak; Han, Jimin; Kim, Hyunsoo; Cho, Kwang Bum; Jung, Min Kyu; Cho, Chang Min; Kim, Tae Nyeun

    2014-05-01

    Acute pancreatitis is an acute inflammatory process of the pancreas with variable involvement of other regional tissues or remote organ systems. Acute fluid collections and pseudocyst formation are the most frequent complications of acute pancreatitis. The aims of this study were to evaluate the incidence, risk factors, and clinical course of pancreatic fluid collections and pseudocyst formation following acute pancreatitis. A prospective multicenter study was conducted in five participating centers with 302 patients diagnosed with acute pancreatitis from January 2011 to July 2012. The incidence of pancreatic fluid collections and pseudocyst was 42.7 and 6.3 %, respectively. Patients with fluid collections were significantly younger, compared to those without fluid collections (51.5 ± 15.9 vs. 60.4 ± 16.5 years, P = 0.000). The proportion of alcoholic etiology (54.3 %) in patients with fluid collections was significantly higher compared to other etiologies (P = 0.000). C-reactive protein (CRP) (48 h) was significantly higher in patients with fluid collections, compared to patients without fluid collections (39.2 ± 77.4 vs. 15.1 ± 36.2 mg/dL, P = 0.016). LDH (48 h) was significantly higher in patients with pseudocyst formation, compared to patients with complete resolution (1,317.6 ± 706.4 vs. 478.7 ± 190.5 IU/L, P = 0.000). Pancreatic fluid collections showed spontaneous resolution in 69.8 % (90/129) and 84.2 % of the pseudocysts disappeared or decreased in size during follow up. Age, CRP (48 h), and alcohol etiology are risk factors for pancreatic fluid collections. LDH (48 h) appears to be a risk factor for pseudocyst formation. Most pseudocysts showed a decrease in size or spontaneous resolution with conservative management.

  6. Molecular identification of drug resistant mutations to tetracycline in Mycoplasma spp. isolated from patients with multiple sclerosis.

    PubMed

    Naghib, M; Kheirkhah, B; Mohebbi, R; Sadeg, L

    2017-08-15

    Bacterial infections play a significant role in causing or intensifying the attacks in MS and there are reports based on the interference of Mycoplasma with a global distribution. Mycoplasma causes autoimmune attacks by imitating the host cell membrane, which is a way of resistance to antibiotics. The purpose of this study was to evaluate the molecular identification of mutations causing resistance to tetracycline in Mycoplasma isolated from MS patients. A total number of 32 cerebrospinal fluid samples and 48 urinal fluid samples were collected from MS patients. The samples were enriched in 7 PPLO broth for one night and continuous cultivation in agar PPLO and PPLO broth for one week. DNA was extracted, and then nested PCR and Doublex PCR were used for bacteria genus identification and the presence of potential tetracycline-resistant alleles (rrs4 and rrs3), respectively.  A total number of 12 samples created colonies. However, only 5 samples (1 cerebrospinal fluid and 4 urinal samples) were detected to be Mycoplasma. The urinal samples showed the desired alleles and were tetracycline-resistant. By sequencing the PCR products, it was shown that these alleles have mutated in various points. Based on the results it seems that the resistant mutated Mycoplasma can be detected in MS patients in our population and may be considered as a risk factor for the disease.

  7. Effect of ligustrazine on levels of amino acid neurotransmitters in rat striatum after cerebral ischemia-reperfusion injury.

    PubMed

    Han, Jin; Wan, Hai-Tong; Yang, Jie-Hong; Zhang, Yu-Yan; Ge, Li-Jun; Bie, Xiao-Dong

    2014-01-01

    This study aimed to evaluate the effect of ligustrazine on levels of amino acid transmitters in the extracellular fluid of striatum following cerebral ischemia/reperfusion (I/R) in male Sprague-Dawley rats. A microdialysis cannula guide was implanted into the right striatum. After recovery, animals underwent a sham operation or middle cerebral artery occlusion (MCAO). Those that developed cerebral ischemia after MCAO were randomized to receive propylene glycol salt water and ligustrazine respectively. Striatal fluid samples were collected from all animals at 15-min intervals after treatment and were subjected to HPLC analysis of aspartic acid, glutamic acid, taurine, and γ-amino butyric acid. Upon the last sample collection, animals were sacrificed and brain tissue specimens were collected for triphenyltetrazolium chloride staining and NeuN staining. Compared with the sham operation, MCAO induced significant neurological deficits and increased striatal concentrations of the four neurotransmitters assessed in a time-dependent manner (P < 0.01). Ligustrazine effectively attenuated the detrimental effects of MCAO on the brain. These observations suggest that ligustrazine as a novel cerebral infarction-protective agent may have potential clinical implications for I/R-related brain damage.

  8. Ball assisted device for analytical surface sampling

    DOEpatents

    ElNaggar, Mariam S; Van Berkel, Gary J; Covey, Thomas R

    2015-11-03

    A system for sampling a surface includes a sampling probe having a housing and a socket, and a rolling sampling sphere within the socket. The housing has a sampling fluid supply conduit and a sampling fluid exhaust conduit. The sampling fluid supply conduit supplies sampling fluid to the sampling sphere. The sampling fluid exhaust conduit has an inlet opening for receiving sampling fluid carried from the surface by the sampling sphere. A surface sampling probe and a method for sampling a surface are also disclosed.

  9. Solid sorbent air sampler

    NASA Technical Reports Server (NTRS)

    Galen, T. J. (Inventor)

    1986-01-01

    A fluid sampler for collecting a plurality of discrete samples over separate time intervals is described. The sampler comprises a sample assembly having an inlet and a plurality of discreet sample tubes each of which has inlet and outlet sides. A multiport dual acting valve is provided in the sampler in order to sequentially pass air from the sample inlet into the selected sample tubes. The sample tubes extend longitudinally of the housing and are located about the outer periphery thereof so that upon removal of an enclosure cover, they are readily accessible for operation of the sampler in an analysis mode.

  10. Polyomavirus BK and JC in individuals with chronic kidney failure, kidney transplantation, and healthy controls.

    PubMed

    Castro, Talita; Fink, Maria Cristina Domingues; Figueiredo, Marilia; Braz-Silva, Paulo Henrique; Pannuti, Cláudio Mendes; Ortega, Karem Lopez; Gallottini, Marina

    2017-04-01

    New clinical approaches to diagnose and monitor individuals with systemic diseases have been employed through the use of oral fluids. Polyomavirus BK (BKPyV) and JC (JCPyV) infect asymptomatically around 80% of general population worldwide remaining latent in the body. In case of immunosuppression, a replication can occur, leading to diseases. The aim of this study was to detect and quantify BKPyV and JCPyV in oral fluids of individuals with chronic kidney failure (CKF), kidney transplantation (KT) and controls compared with their detection in blood and urine, traditionally used for this test. Forty six subjects were included and distributed into 3 groups: 14 with CKF (Group 1), 12 with KT (Group 2) and 20 healthy individuals (Group 3). In a total, 315 samples were collected and analyzed through RT-PCR, being 151 of gingival crevicular fluid, 46 of saliva, 46 of mouthwash, 43 of blood and 29 of urine. All subjects from group 1 were positive for BKPyV in at least one collected samples and 14% were positive for JCPyV. In Group 2, 91.7% were positive for BKPyV and 51.7% for JCPyV. Among subjects of Group 3, 80% were positive for BKPyV and 45% for JCPyV. Oral fluids exhibited high prevalence of BKPyV and JCPyV and were equally efficient compared to urine and blood. The use of oral fluids to detect these polyomaviruses enhances positivity in screening, even in cases of absence of viremia and especially in individuals who are not able to urinate. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Evaluation of some heavy metals concentration in body fluids of metal workers in Kano metropolis, Nigeria.

    PubMed

    Sani, Ali; Abdullahi, Ibrahim Lawal

    2017-01-01

    Metal workers in urban Kano constitute a major workforce with a considerable population. The present work was aimed at obtaining baseline data on the extent of metal ion concentration in body fluids (urine and blood) of sampled population in the area. The investigation involves interaction with sampled population as well as blood and urine sample collection for heavy metals analysis. The health problems associated with the practice identified by respondents include: metal fume fever; eye and skin irritation; dizziness and respiratory problems; lack of or inadequate protective devices during activity were also reported. Laboratory investigation of urine samples by Atomic absorption spectrophotometry indicated higher concentrations for Manganese (Mn), Lead (Pb) and Nickel (Ni); in blood samples, there were higher concentrations of Manganese (Mn), Lead (Pb), Chromium (Cr) and Nickel (Ni). Metal workers of urban Kano are at risk because of the concentration of Mn and Pb in particular. There is the need to monitor occupational activities that are responsible for pollution and with serious health risk.

  12. Ultra‐high performance supercritical fluid chromatography of lignin‐derived phenols from alkaline cupric oxide oxidation

    PubMed Central

    Sun, Mingzhe; Lidén, Gunnar; Sandahl, Margareta

    2016-01-01

    Traditional chromatographic methods for the analysis of lignin‐derived phenolic compounds in environmental samples are generally time consuming. In this work, an ultra‐high performance supercritical fluid chromatography method with a diode array detector for the analysis of major lignin‐derived phenolic compounds produced by alkaline cupric oxide oxidation was developed. In an analysis of a collection of 11 representative monomeric lignin phenolic compounds, all compounds were clearly separated within 6 min with excellent peak shapes, with a limit of detection of 0.5–2.5 μM, a limit of quantification of 2.5–5.0 μM, and a dynamic range of 5.0–2.0 mM (R 2 > 0.997). The new ultra‐high performance supercritical fluid chromatography method was also applied for the qualitative and quantitative analysis of lignin‐derived phenolic compounds obtained upon alkaline cupric oxide oxidation of a commercial humic acid. Ten out of the previous eleven model compounds could be quantified in the oxidized humic acid sample. The high separation power and short analysis time obtained demonstrate for the first time that supercritical fluid chromatography is a fast and reliable technique for the analysis of lignin‐derived phenols in complex environmental samples. PMID:27452148

  13. High density grids

    DOEpatents

    Cohen, Aina E.; Baxter, Elizabeth L.

    2018-01-16

    An X-ray data collection grid device is provided that includes a magnetic base that is compatible with robotic sample mounting systems used at synchrotron beamlines, a grid element fixedly attached to the magnetic base, where the grid element includes at least one sealable sample window disposed through a planar synchrotron-compatible material, where the planar synchrotron-compatible material includes at least one automated X-ray positioning and fluid handling robot fiducial mark.

  14. Endoscopic management of peripancreatic fluid collections.

    PubMed

    Goyal, Jatinder; Ramesh, Jayapal

    2015-07-01

    Peripancreatic fluid collections are a well-known complication of pancreatitis and can vary from fluid-filled collections to entirely necrotic collections. Although most of the fluid-filled pseudocysts tend to resolve spontaneously with conservative management, intervention is necessary in symptomatic patients. Open surgery has been the traditional treatment modality of choice though endoscopic, laparoscopic and transcutaneous techniques offer alternative drainage approaches. During the last decade, improvement in endoscopic ultrasound technology has enabled real-time access and drainage of fluid collections that were previously not amenable to blind transmural drainage. This has initiated a trend towards use of this modality for treatment of pseudocysts. In this review, we have summarised the existing evidence for endoscopic drainage of peripancreatic fluid collections from published studies.

  15. Field Detection of Drugs of Abuse in Oral Fluid Using the Alere™ DDS®2 Mobile Test System with Confirmation by Liquid Chromatography Tandem Mass Spectrometry (LC-MS/MS).

    PubMed

    Krotulski, Alex J; Mohr, Amanda L A; Friscia, Melissa; Logan, Barry K

    2018-04-01

    The collection and analysis of drugs in oral fluid (OF) at the roadside has become more feasible with the introduction of portable testing devices such as the Alere™ DDS®2 Mobile Test System (DDS®2). The objective of this study was to compare the on-site results for the DDS®2 to laboratory-based confirmatory assays with respect to detection of drugs of abuse in human subjects. As part of a larger Institutional Review Board approved study, two OF samples were collected from each participant at a music festival in Miami, FL, USA. One OF sample was field screened using the DDS®2, and a confirmatory OF sample was collected using the Quantisal™ OF collection device and submitted to the laboratory for testing. In total, 124 subjects participated in this study providing two contemporaneous OF samples. DDS®2 field screening yielded positive results for delta-9-tetrahydrocannabinol (THC) (n = 27), cocaine (n = 12), amphetamine (n = 3), methamphetamine (n = 3) and benzodiazepine (n = 1). No opiate-positive OF samples were detected. For cocaine, amphetamine, methamphetamine and benzodiazepines, the DDS®2 displayed sensitivity, specificity and accuracy of 100%. For THC, the DDS®2 displayed sensitivity of 90%, specificity of 100% and accuracy of 97.5%, when the threshold for confirmation matched that of the manufacturers advertised cut-off. When this confirmatory threshold was lowered to the analytical limit of detection (i.e., 1 ng/mL), apparent device performance for THC was poorer due to additional samples testing positive by confirmatory assay that had tested negative on the DDS®2, demonstrating a need for correlation between manufacturer cut-off and analytical reporting limit. These results from drug-using subjects demonstrate the value of field-based OF testing, and illustrate the significance of selecting an appropriate confirmation cut-off concentration with respect to performance evaluation and detection of drug use.

  16. A modified method using the SonoPrep ultrasonic skin permeation system for sampling human interstitial fluid is compatible with proteomic techniques.

    PubMed

    Lecomte, Marie M J; Atkinson, Kelly R; Kay, Daniel P; Simons, Joanne L; Ingram, John R

    2013-02-01

    The use of biomarkers in skin is a novel diagnostic tool. Interstitial fluid (ISF) from skin provides a snapshot of proteins secreted at the time of sampling giving insights into the patient's health status. A minimally invasive technique for the transdermal collection of human ISF proteins. A low frequency ultrasonic skin permeation device (SonoPrep ultrasonic skin permeation system) was used to produce micropores in the stratum corneum through which ISF was extracted using a portable pulsed vacuum ISF collection device. On average, protein concentrations recovered ranged between 0.064 and 4.792 μg/μL (mean 1.258 μg/μL). Two-dimensional gel electrophoresis revealed that this sample type was amenable to this type of analysis. Gel images indicated that both highly abundant proteins and lower abundance proteins were isolated from the skin. Western blot analysis confirmed the presence of proteins commonly found in plasma and the epidermis. A minimally invasive method for the transdermal recovery of ISF proteins has been developed. We have demonstrated that ISF samples obtained using this approach can be analysed with proteomic techniques, such as two-dimensional gel electrophoresis and western blots, providing another tool for the identification of disease specific protein biomarkers. © 2012 John Wiley & Sons A/S.

  17. Heparin-binding EGF-like growth factor is present in human amniotic fluid and breast milk.

    PubMed

    Michalsky, M P; Lara-Marquez, M; Chun, L; Besner, G E

    2002-01-01

    Heparin-binding EGF-like growth factor (HB-EGF) is a member of the epidermal growth factor (EGF) family that has been implicated in the healing of various organ injuries. Endogenous HB-EGF production is upregulated in response to injury to the kidney, liver, brain, skin, and intestine. Exogenous administration of HB-EGF protects against intestinal epithelial cell apoptosis and necrosis and intestinal ischemia/reperfusion (I/R) injury. This study examines the presence of endogenous HB-EGF in human amniotic fluid and breast milk, fluids that are in intimate contact with the developing and neonatal gastrointestinal tract. Breast milk samples were collected from lactating women and amniotic fluid was gathered from full-term uteri (cesarian sections) or preterm uteri (amniocentesis). Crude and partially purified breast milk and amniotic fluid samples were analyzed for HB-EGF levels using an HB-EGF-specific enzyme-linked immunosorbent assay (ELISA). Analysis results showed detectable HB-EGF levels in human amniotic fluid and breast milk, ranging from 0.2 to 230 pg/mL. Breast milk and amniotic fluid subjected to heparin affinity or HB-EGF-affinity column chromatography showed bioactivity eluting at positions consistent with those known for native HB-EGF. This study represents the first report of detectable HB-EGF in human amniotic fluid and breast milk. The presence of HB-EGF in these fluids may serve a role in the development of the gastrointestinal tract in utero, and in protection against gut mucosal injury after birth. Copyright 2002 by W.B. Saunders Company.

  18. Detection of Delta9-tetrahydrocannabinol and amphetamine-type stimulants in oral fluid using the Rapid Stat point-of-collection drug-testing device.

    PubMed

    Röhrich, J; Zörntlein, S; Becker, J; Urban, R

    2010-04-01

    The Rapid Stat assay, a point-of-collection drug-testing device for detection of amphetamines, cannabinoids, cocaine, opiates, methadone, and benzodiazepines in oral fluid, was evaluated for cannabis and amphetamine-type stimulants. The Rapid Stat tests (n = 134) were applied by police officers in routine traffic checks. Oral fluid and blood samples were analyzed using gas chromatography-mass spectrometry (GC-MS) for Delta(9)-tetrahydrocannabinol, amphetamine, methamphetamine, methylenedioxymethamphetamine, methylenedioxyethylamphetamine, and methylenedioxyamphetamine. The comparison of GC-MS analysis of oral fluid with the Rapid Stat results for cannabis showed a sensitivity of 85%, a specificity of 87%, and a total confirmation rate of 87%. When compared with serum, the sensitivity of the cannabis assay decreased to 71%, the specificity to 60%, and the total confirmation rate to 66%. These findings were possibly caused by an incorrect reading of the THC test results. Comparison of the Rapid Stat amphetamine assay with GC-MS in oral fluid showed a sensitivity of 94%, a specificity of 97%, and a total confirmation rate of 97%. Compared with serum, a sensitivity of 100%, a specificity of 90%, and a total confirmation rate of 92% was found. The amphetamine assay must, therefore, be regarded as satisfactory.

  19. Microbial communities at the borehole observatory on the Costa Rica Rift flank (Ocean Drilling Program Hole 896A).

    PubMed

    Nigro, Lisa M; Harris, Kate; Orcutt, Beth N; Hyde, Andrew; Clayton-Luce, Samuel; Becker, Keir; Teske, Andreas

    2012-01-01

    The microbiology of subsurface, hydrothermally influenced basaltic crust flanking mid-ocean ridges has remained understudied, due to the difficulty in accessing the subsurface environment. The instrumented boreholes resulting from scientific ocean drilling offer access to samples of the formation fluids circulating through oceanic crust. We analyzed the phylogenetic diversity of bacterial communities of fluid and microbial mat samples collected in situ from the observatory at Ocean Drilling Program Hole 896A, drilled into ~6.5 million-year-old basaltic crust on the flank of the Costa Rica Rift in the equatorial Pacific Ocean. Bacterial 16S rRNA gene sequences recovered from borehole fluid and from a microbial mat coating the outer surface of the fluid port revealed both unique and shared phylotypes. The dominant bacterial clones from both samples were related to the autotrophic, sulfur-oxidizing genus Thiomicrospira. Both samples yielded diverse gamma- and alphaproteobacterial phylotypes, as well as members of the Bacteroidetes, Planctomycetes, and Verrucomicrobia. Analysis of ribulose-1,5-bisphosphate carboxylase/oxygenase (RuBisCO) genes (cbbL and cbbM) from the sampling port mat and from the borehole fluid demonstrated autotrophic carbon assimilation potential for in situ microbial communities; most cbbL genes were related to those of the sulfur-oxidizing genera Thioalkalivibrio and Thiomicrospira, and cbbM genes were affiliated with uncultured phylotypes from hydrothermal vent plumes and marine sediments. Several 16S rRNA gene phylotypes from the 896A observatory grouped with phylotypes recovered from seawater-exposed basalts and sulfide deposits at inactive hydrothermal vents, but there is little overlap with hydrothermally influenced basaltic boreholes 1026B and U1301A on the Juan de Fuca Ridge flank, suggesting that site-specific characteristics of Hole 896A (i.e., seawater mixing into borehole fluids) affect the microbial community composition.

  20. Effect of semen collection method on sperm motility of gray wolves (Canis lupus) and domestic dogs (C. l. familiaris).

    PubMed

    Christensen, Bruce W; Asa, Cheryl S; Wang, Chong; Vansandt, Lindsey; Bauman, Karen; Callahan, Margaret; Jens, Jackie K; Ellinwood, N Matthew

    2011-09-15

    Genetic management of Mexican gray wolves includes semen banking, but due to the small number of animals in the population and handling restrictions, improvements in semen collection and cryopreservation rely on results from studies of domestic dogs. Semen collection from wolves requires anesthesia and electroejaculation, which introduce potentially important variables into species comparisons, as dog semen is typically collected manually from conscious animals. To investigate possible effects of collection method on semen quality, we compared semen collection by the traditional manual method and by electroejaculation (EE) in a group of dogs (n = 5) to collection by EE only in wolves (n = 7). Samples were divided into two aliquots: neat or diluted in Tris/egg yolk extender, with motility evaluated at intervals up to 24 h. There were no differences (P > 0.10) in sperm motility in either neat or extended samples at 24 h from EE dogs and wolves, although motility of the wolf neat samples declined more rapidly (P < 0.05). However, there were differences (P < 0.01) between EE and manually collected dog semen in motility at 24 h, in both the neat and extended samples. Therefore, general motility patterns of dog and wolf semen collected by EE were similar, especially when diluted with a Tris/egg yolk extender, but sperm collected from dogs by EE did not maintain motility as long as manually collected samples, perhaps related to the longer exposure of EE samples to more prostate fluid. Copyright © 2011 Elsevier Inc. All rights reserved.

  1. Comparison of Cannabinoid Concentrations in Plasma, Oral Fluid and Urine in Occasional Cannabis Smokers After Smoking Cannabis Cigarette.

    PubMed

    Marsot, Amélie; Audebert, Christine; Attolini, Laurence; Lacarelle, Bruno; Micallef, Joelle; Blin, Olivier

    A randomized cross-over, double blind placebo controlled study of smoked cannabis was carried out on occasional cannabis smokers. The objective of this research was to describe the pharmacokinetic parameters of THC and its metabolites in plasma, oral fluid and urine, from samples obtained simultaneously to provide estimations of THC and metabolites concentrations after smoking a cannabis cigarette. Blood, oral fluid and urine samples were collected until up to 72 h after smoking the cannabis cigarette (4% of delta-9-tetrathydrocannabinol (THC)). THC, 11-OH-THC and THC-COOH were analyzed by gas-chromatography-mass spectrometry. Pharmacokinetic parameters were estimated from these data. Eighteen male healthy adults participated in the study. In total, 560 plasma, 288 oral fluid and 448 urine samples were quantified for cannabinoids. Plasma, oral fluid and urine pharmacokinetic parameters were calculated. A wide range of median THC Cmax (1.6-160.0 µg/L and 55.4-123120.0 µg/L in plasma and oral fluid, respectively), 11-OH-THC Cmax (0-11.1 µg/L in plasma) and THC-COOH Cmax (1.0-56.3 µg/L in plasma) was observed. When expressed as a percentage of the total available THC dose, and corrected for molar equivalents, mean percentage of total THC dose excreted was 1.9 +/-2.5 % with range of 0.2-7.5%. This high inter-individual variability was also observed on other calculated pharmacokinetic parameters. Prediction of plasma THC concentration from THC oral fluid concentration or from THC-COOH urinary concentrations is not feasible due to the large variations observed. The results from this study support the assumption that a positive oral fluid THC result or a positive urine fluid result are indicative of a recent cannabis exposure. This article is open to POST-PUBLICATION REVIEW. Registered readers (see "For Readers") may comment by clicking on ABSTRACT on the issue's contents page.

  2. A Novel Device Addressing Design Challenges for Passive Fluid Phase Separations Aboard Spacecraft

    NASA Astrophysics Data System (ADS)

    Weislogel, M. M.; Thomas, E. A.; Graf, J. C.

    2009-07-01

    Capillary solutions have long existed for the control of liquid inventories in spacecraft fluid systems such as liquid propellants, cryogens and thermal fluids for temperature control. Such large length scale, `low-gravity,' capillary systems exploit container geometry and fluid properties—primarily wetting—to passively locate or transport fluids to desired positions for a variety of purposes. Such methods have only been confidently established if the wetting conditions are known and favorable. In this paper, several of the significant challenges for `capillary solutions' to low-gravity multiphase fluids management aboard spacecraft are briefly reviewed in light of applications common to life support systems that emphasize the impact of the widely varying wetting properties typical of aqueous systems. A restrictive though no less typifying example of passive phase separation in a urine collection system is highlighted that identifies key design considerations potentially met by predominately capillary solutions. Sample results from novel scale model prototype testing aboard a NASA low-g aircraft are presented that support the various design considerations.

  3. Weight loss reduces breast ductal fluid estrogens in obese postmenopausal women: a single arm intervention pilot study.

    PubMed

    Carpenter, Catherine L; Duvall, Karen; Jardack, Patricia; Li, Luyi; Henning, Susanne M; Li, Zhaoping; Heber, David

    2012-12-05

    Accumulation of excess body fat increases breast cancer risk after menopause. Whether the localized breast is differently influenced by adipose tissue compared to the rest of the body, has not been well studied. Our purpose was to demonstrate feasibility and preliminarily evaluate serum-based and localized breast biomarker changes resulting from a weight loss intervention among obese postmenopausal women. We conducted a 12-week pilot controlled dietary and exercise intervention among healthy obese postmenopausal women, collected serum and breast ductal fluid before and after the intervention, and estimated the association with systemic and localized biomarker changes. We recruited 7 obese (mean body mass index = 33.6 kg/m2) postmenopausal women. We collected samples at baseline and the 12th week for: anthropometry; phlebotomy; dual-energy x-ray absorptiometry (lean and fat mass); exercise fitness (maximum oxygen consumption (VO2Max); 1-repetition strength maximum); and breast ductal lavage. Changes from baseline occurred in body composition and exercise performance including fat mass loss (14% average drop), VO2Max (+36% increase) and strength improvement (+26%). Breast ductal fluid markers declined from baseline with estradiol showing a 24% reduction and IL-6 a 20% reduction. We also observed serum biomarker reductions from baseline including leptin (36% decline), estrone sulfate (-10%), estradiol (-25%), and Il-6 (-33%). Conduct of the diet and exercise intervention, collection of ductal fluid, and measurement of hormones and cytokines contained in the ductal fluid were all feasible. We preliminarily demonstrated estradiol and IL-6 reductions from baseline in both serum and breast ductal fluid among obese postmenopausal women who participated in the 12-week weight loss diet and exercise intervention.

  4. Development and validation of dried matrix spot sampling for the quantitative determination of amyloid β peptides in cerebrospinal fluid.

    PubMed

    Delaby, Constance; Gabelle, Audrey; Meynier, Philippe; Loubiere, Vincent; Vialaret, Jérôme; Tiers, Laurent; Ducos, Jacques; Hirtz, Christophe; Lehmann, Sylvain

    2014-05-01

    The use of dried blood spots on filter paper is well documented as an affordable and practical alternative to classical venous sampling for various clinical needs. This technique has indeed many advantages in terms of collection, biological safety, storage, and shipment. Amyloid β (Aβ) peptides are useful cerebrospinal fluid (CSF) biomarkers for Alzheimer disease diagnosis. However, Aβ determination is hindered by preanalytical difficulties in terms of sample collection and stability in tubes. We compared the quantification of Aβ peptides (1-40, 1-42, and 1-38) by simplex and multiplex ELISA, following either a standard operator method (liquid direct quantification) or after spotting CSF onto dried matrix paper card. The use of dried matrix spot (DMS) overcame preanalytical problems and allowed the determination of Aβ concentrations that were highly commutable (Bland-Altman) with those obtained using CSF in classical tubes. Moreover, we found a positive and significant correlation (r2=0.83, Pearson coefficient p=0.0329) between the two approaches. This new DMS method for CSF represents an interesting alternative that increases the quality and efficiency in preanalytics. This should enable the better exploitation of Aβ analytes for Alzheimer's diagnosis.

  5. Delayed methotrexate excretion in infants and young children with primary central nervous system tumors and postoperative fluid collections.

    PubMed

    Wright, Karen D; Panetta, John C; Onar-Thomas, Arzu; Reddick, Wilburn E; Patay, Zoltan; Qaddoumi, Ibrahim; Broniscer, Alberto; Robinson, Giles; Boop, Frederick A; Klimo, Paul; Ward, Deborah; Gajjar, Amar; Stewart, Clinton F

    2015-01-01

    High-dose methotrexate (HD-MTX) has been used to treat children with central nervous system tumors. Accumulation of MTX within pleural, peritoneal, or cardiac effusions has led to delayed excretion and increased risk of systemic toxicity. This retrospective study analyzed the association of intracranial post-resection fluid collections with MTX plasma disposition in infants and young children with brain tumors. Brain MRI findings were analyzed for postoperative intracranial fluid collections in 75 pediatric patients treated with HD-MTX and for whom serial MTX plasma concentrations (MTX) were collected. Delayed plasma excretion was defined as (MTX) ≥1 μM at 42 hours (h). Leucovorin was administered at 42 h and then every 6 h until (MTX) <0.1 μM. Population and individual MTX pharmacokinetic parameters were estimated by nonlinear mixed-effects modeling. Fifty-eight patients had intracranial fluid collections present. Population average (inter-individual variation) MTX clearance was 96.0 ml/min/m² (41.1 CV %) and increased with age. Of the patients with intracranial fluid collections, 24 had delayed excretion; only 2 of the 17 without fluid collections (P < 0.04) had delayed excretion. Eleven patients had grade 3 or 4 toxicities attributed to HD-MTX. No significant difference was observed in intracranial fluid collection, total leucovorin dosing, or hydration fluids between those with and without toxicity. Although an intracranial fluid collection is associated with delayed MTX excretion, HD-MTX can be safely administered with monitoring of infants and young children with intracranial fluid collections. Infants younger than 1 year may need additional monitoring to avoid toxicity.

  6. Passive, Collapsible Contingency Urinal for Human Space Flight

    NASA Technical Reports Server (NTRS)

    Jenson, Ryan

    2015-01-01

    Fluid transport systems for spacecraft face acute challenges because of the persistently unfamiliar and unforgiving low-gravity environment. IRPI, LLC, has developed a contingency wastewater collection and processing device that provides passive liquid collation, containment, bubble separation, and droplet coalescence functions. The lightweight, low-volume, low-cost, and potentially disposable device may be used for subsequent sampling, metering, storage, disposal, and/or reuse. The approach includes a fractal wetting design that incorporates smart capillary fluidics. This work could have a broad impact on capillary-based fluid management on spacecraft and on Earth.

  7. Characterization of the microbiome of nipple aspirate fluid of breast cancer survivors.

    PubMed

    Chan, Alfred A; Bashir, Mina; Rivas, Magali N; Duvall, Karen; Sieling, Peter A; Pieber, Thomas R; Vaishampayan, Parag A; Love, Susan M; Lee, Delphine J

    2016-06-21

    The microbiome impacts human health and disease. Until recently, human breast tissue and milk were presumed to be sterile. Here, we investigated the presence of microbes in the nipple aspirate fluid (NAF) and their potential association with breast cancer. We compared the NAF microbiome between women with a history of breast cancer (BC) and healthy control women (HC) using 16S rRNA gene amplicon sequencing. The NAF microbiome from BC and HC showed significant differences in community composition. Two Operational Taxonomic Units (OTUs) showed differences in relative abundances between NAF collected from BC and HC. In NAF collected from BC, there was relatively higher incidence of the genus Alistipes. By contrast, an unclassified genus from the Sphingomonadaceae family was relatively more abundant in NAF from HC. These findings reflect the ductal source DNA since there were no differences between areolar skin samples collected from BC and HC. Furthermore, the microbes associated with BC share an enzymatic activity, Beta-Glucuronidase, which may promote breast cancer. This is the first report of bacterial DNA in human breast ductal fluid and the differences between NAF from HC and BC. Further investigation of the ductal microbiome and its potential role in breast cancer are warranted.

  8. An evaluation of analytical methods, air sampling techniques, and airborne occupational exposure of metalworking fluids.

    PubMed

    Verma, Dave K; Shaw, Don S; Shaw, M Lorraine; Julian, Jim A; McCollin, Shari-Ann; des Tombe, Karen

    2006-02-01

    This article summarizes an assessment of air sampling and analytical methods for both oil and water-based metalworking fluids (MWFs). Three hundred and seventy-four long-term area and personal airborne samples were collected at four plants using total (closed-face) aerosol samplers and thoracic samplers. A direct-reading device (DustTrak) was also used. The processes sampled include steel tube making, automotive component manufacturing, and small part manufacturing in a machine shop. The American Society for Testing and Materials (ASTM) Method PS42-97 of analysis was evaluated in the laboratory. This evaluation included sample recovery, determination of detection limits, and stability of samples during storage. Results of the laboratory validation showed (a) the sample recovery to be about 87%, (b) the detection limit to be 35 microg, and (c) sample stability during storage at room temperature to decline rapidly within a few days. To minimize sample loss, the samples should be stored in a freezer and analyzed within a week. The ASTM method should be the preferred method for assessing metalworking fluids (MWFs). The ratio of thoracic aerosol to total aerosol ranged from 0.6 to 0.7. A similar relationship was found between the thoracic extractable aerosol and total extractable aerosol. The DustTrak, with 10-microm sampling head, was useful in pinpointing the areas of potential exposure. MWF exposure at the four plants ranged from 0.04 to 3.84 mg/m3 with the geometric mean ranging between 0.22 to 0.59 mg/m3. Based on this data and the assumption of log normality, MWF exposures are expected to exceed the National Institute for Occupational Safety and Health recommended exposure limit of 0.5 mg/m3 as total mass and 0.4 mg/m3 as thoracic mass about 38% of the time. In addition to controlling airborne MWF exposure, full protection of workers would require the institution of programs for fluid management and dermal exposure prevention.

  9. Chromosomal studies on 2 mL of celomic fluid obtained during the fifth week of development in the timed-pregnant baboon model.

    PubMed

    Santolaya-Forgas, Joaquin; De Leon-Luis, Juan; Shen, Zhion; McCorquodale, Maureen

    2005-09-01

    To determine if chromosomal studies could be performed using 2 mL of celomicfluid obtained during the fifth postfertilization week in pregnant baboons. Nine ultrasound-guided celocenteses were performed. The initial 0.5 mL of celomic fluid was discarded to decrease maternal cell contamination. Approximately 2 mL of celomic fluid was then collected. The fluid was centrifuged and the supernatant removed to a final volume of 0.5 mL. The celomic fluid sample was placed in either a small plastic flaskette chamber slide with a mix of 0.5 mL celomic fluid, 1 mL of Amniomax, and 1 mL of usedfibroblast culture medium to spread on the entire surface (n=4), or a 3.5 x 1-cm plastic Petri dish with a 24 x 30-mm glass coverslip to keep the 0.5 mL celomic fluid mixed with 1 mL of Amniomax (Invitrogen, Carlsbad, California) within a 1 cm2 area (n=5). The medium was changed on day 5 and thereafter every second to third day. The cells were harvested when the number of cells appeared sufficient for chromosomal analysis. Standard chromosomal studies were possible in 5 of the 9 celomicfluid samples. Mean (+/-SD) celomic fluid volume used for culture was 1.85 +/- 0.3 mL. Mean (+/-SD) time to karyotype result was 18.8 +/- 1.8 days. The findings of this study suggest that there are living cells at 36-42 days of embryonic development in the extraembryonic celomic fluid of primates and that they can be cultured for chromosomal studies. However, significant improvements in understanding the biology of cells present at 5 weeks after fertilization in celomic fluid are needed to improve culture conditions.

  10. Fluid collections in amputations are not indicative or predictive of infection.

    PubMed

    Polfer, Elizabeth M; Hoyt, Benjamin W; Senchak, Lien T; Murphey, Mark D; Forsberg, Jonathan A; Potter, Benjamin K

    2014-10-01

    In the acute postoperative period, fluid collections are common in lower extremity amputations. Whether these fluid collections increase the risk of infection is unknown. The purposes of this study were to determine (1) the percentage of patients who develop postoperative fluid collections in posttraumatic amputations and the natural course of the collection; (2) whether patients who develop these collections are at increased risk for infection; and to ask (3) are there objective clinical or radiologic signs that are associated with likelihood of infection when a fluid collection is present? We performed a review of all 300 patients injured in combat operations who sustained at least one major lower extremity amputation (at or proximal to the tibiotalar joint) and were treated definitively at our institution between March 2005 and April 2009. We segregated the groups based on whether cross-sectional imaging was performed less than 3 months (early group) after closure, greater than 3 months (late group) after closure, or not at all (control group, baseline frequency of infection). Our primary study cohort where those patients with a fluid collection in the first three months. The clinical course was reviewed and the primary outcome was a return to the operating room for irrigation and débridement with positive cultures. For those patients with cross-sectional imaging, we also collected objective clinical parameters within 24 hours of the scan (white blood cell count, maximum temperature, presence of bacteremia, tachycardia, oxygen desaturation), extremity examination (presence of erythema, warmth, and/or drainage), and characteristics of the fluid collections seen (size of the fluid collection, enhancement, complexity (simple versus loculated), surrounding edema, skin changes, tract formation, presence of air, and changes within the bone itself). The presence of a fluid collection on imaging was analyzed to determine whether it was associated with infection. We further analyzed clinical parameters, objective physical examination findings at the extremity, and characteristics of the fluid collection to determine if there were other parameters associated with infection. Over half (55%) of the limbs demonstrated fluid collection in the early postoperative period and the prevalence decreased in the late group (11%; p = 0.001). There was no association between the presence of a fluid collection and infection. However, there was an association between objective clinical signs at the extremity (erythema and/or drainage) and infection (p < 0.001) in our primary study cohort. Fluid collections are common in combat-related amputations in the immediate postoperative period and become smaller and less frequent over time. In the absence of extremity erythema and wound drainage, imaging of a residual limb to evaluate for the presence of a fluid collection appears to be of little clinical use.

  11. Effective surveillance for early classical swine fever virus detection will utilize both virus and antibody detection capabilities.

    PubMed

    Panyasing, Yaowalak; Kedkovid, Roongtham; Thanawongnuwech, Roongroje; Kittawornrat, Apisit; Ji, Ju; Giménez-Lirola, Luis; Zimmerman, Jeffrey

    2018-03-01

    Early recognition and rapid elimination of infected animals is key to controlling incursions of classical swine fever virus (CSFV). In this study, the diagnostic characteristics of 10 CSFV assays were evaluated using individual serum (n = 601) and/or oral fluid (n = 1417) samples collected from -14 to 28 days post inoculation (DPI). Serum samples were assayed by virus isolation (VI), 2 commercial antigen-capture enzyme-linked immunosorbent assays (ELISA), virus neutralization (VN), and 3 antibody ELISAs. Both serum and oral fluid samples were tested with 3 commercial real-time reverse transcription-polymerase chain reaction (rRT-PCR) assays. One or more serum samples was positive by VI from DPIs 3 to 21 and by antigen-capture ELISAs from DPIs 6 to 17. VN-positive serum samples were observed at DPIs ≥ 7 and by antibody ELISAs at DPIs ≥ 10. CSFV RNA was detected in serum samples from DPIs 2 to 28 and in oral fluid samples from DPIs 4 to 28. Significant differences in assay performance were detected, but most importantly, no single combination of sample and assay was able to dependably identify CSFV-inoculated pigs throughout the 4-week course of the study. The results show that effective surveillance for CSFV, especially low virulence strains, will require the use of PCR-based assays for the detection of early infections (<14 days) and antibody-based assays, thereafter. Copyright © 2018 Elsevier B.V. All rights reserved.

  12. Assessing Microbial Activity in Marcellus Shale Hydraulic Fracturing Fluids

    NASA Astrophysics Data System (ADS)

    Wishart, J. R.; Morono, Y.; Itoh, M.; Ijiri, A.; Hoshino, T.; Inagaki, F.; Verba, C.; Torres, M. E.; Colwell, F. S.

    2014-12-01

    Hydraulic fracturing (HF) produces millions of gallons of waste fluid which contains a microbial community adapted to harsh conditions such as high temperatures, high salinities and the presence of heavy metals and radionuclides. Here we present evidence for microbial activity in HF production fluids. Fluids collected from a Marcellus shale HF well were supplemented with 13C-labeled carbon sources and 15N-labeled ammonium at 25°C under aerobic or anaerobic conditions. Samples were analyzed for 13C and 15N incorporation at sub-micrometer scale by ion imaging with the JAMSTEC NanoSIMS to determine percent carbon and nitrogen assimilation in individual cells. Headspace CO2 and CH4 were analyzed for 13C enrichment using irm-GC/MS. At 32 days incubation carbon assimilation was observed in samples containing 1 mM 13C-labeled glucose under aerobic and anaerobic conditions with a maximum of 10.4 and 6.5% total carbon, respectively. Nitrogen assimilation of 15N ammonium observed in these samples were 0.3 and 0.8% of total nitrogen, respectively. Head space gas analysis showed 13C enrichment in CH4 in anaerobic samples incubated with 1mM 13C-labeled bicarbonate (2227 ‰) or methanol (98943 ‰). Lesser 13C enrichment of CO2 was observed in anaerobic samples containing 1 mM 13C-labeled acetate (13.7 ‰), methanol (29.9 ‰) or glucose (85.4 ‰). These results indicate metabolic activity and diversity in microbial communities present in HF flowback fluids. The assimilation of 13C-labeled glucose demonstrates the production of biomass, a critical part of cell replication. The production of 13CO2 and 13CH4 demonstrate microbial metabolism in the forms of respiration and methanogenesis, respectively. Methanogenesis additionally indicates the presence of an active archaeal community. This research shows that HF production fluid chemistry does not entirely inhibit microbial activity or growth and encourages further research regarding biogeochemical processes occurring in Marcellus shale HF wells. Biogeochemical activity may impact the efficacy of HF and natural gas production as well as the chemistry of produced fluids which have become an environmental and public health concern.

  13. Speciation of arsenic, selenium, and chromium in wildfire impacted soils and ashes

    USGS Publications Warehouse

    Wolf, Ruth E.; Hoefen, Todd M.; Hageman, Philip L.; Morman, Suzette A.; Plumlee, Geoffrey S.

    2010-01-01

    In 2007-09, California experienced several large wildfires that damaged large areas of forest and destroyed many homes and buildings. The U.S. Geological Survey collected samples from the Harris, Witch, Grass Valley, Ammo, Santiago, Canyon, Jesusita, and Station fires for testing to identify any possible characteristics of the ashes and soils from burned areas that may be of concern for their impact on water quality, human health, and endangered species. The samples were subjected to analysis for bulk chemical composition for 44 elements by inductively coupled plasma mass spectrometry (ICP-MS) after acid digestion and de-ionized water leach tests for pH, alkalinity, conductivity, and anions. Water leach tests generated solutions ranging from pH 10-12, suggesting that ashes can generate caustic alkalinity in contact with rainwater or body fluids (for example, sweat and fluids in the respiratory tract). Samples from burned residential areas in the 2007 fires had elevated levels for several metals, including: As, Pb, Sb, Cu, Zn, and Cr. In some cases, the levels found were above the U.S. Environmental Protection Agency (USEPA) preliminary remediation goals (PRG) for soils. Speciation analyses were conducted on de-ionized water and simulated lung fluid leachates for As(III), As(V), Se(IV), Se(VI), Cr(III), and Cr(VI). All species were determined in the same analytical run using an ion-pairing HPLC-ICP-MS method. For leachates containing high levels of total Cr, the majority of the chromium was present in the hexavalent, Cr(VI), form. Higher total and hexavalent chromium levels were observed for samples collected from burned residential areas. Arsenic was also generally present in the more oxidized, As(V), form. Selenium (IV) and (VI) were present, but typically at levels below 2 ppb for most samples. Stability studies of leachate solutions under different storage conditions were performed and the suitability of different sample preservation methods for speciation analysis will be discussed.

  14. Sulforaphane Modulates Joint Inflammation in a Murine Model of Complete Freund's Adjuvant-Induced Mono-Arthritis.

    PubMed

    Silva Rodrigues, João Francisco; Silva E Silva, Cristiane; França Muniz, Thayanne; de Aquino, Alana Fernanda; Neuza da Silva Nina, Larissa; Fialho Sousa, Nagila Caroline; Nascimento da Silva, Luis Claudio; de Souza, Breno Glaessner Gomes Fernandes; da Penha, Tatiana Aranha; Abreu-Silva, Ana Lúcia; de Sá, Joicy Cortez; Soares Fernandes, Elizabeth; Grisotto, Marcos Augusto Grigolin

    2018-04-24

    Rheumatoid arthritis (RA) is characterized by inflammation of one or more joints, and affects ~1% of the adult population worldwide. Sulforaphane (SFN) is a natural compound that has been suggested as an antioxidant. Here, SFN’s effects were evaluated in a murine mono-arthritis model. Mono-arthritis was induced in mice by a single intra-articular injection of Complete Freund’s Adjuvant (CFA-10 µg/joint, in 10 µL) into the ipsilateral joint. The contralateral joint received an equal volume of PBS. On the 4th day post-joint inflammation induction, animals received either SFN (10 mg/kg) or vehicle (3% DMSO in saline), intraperitoneally (i.p.), twice a day for 3 days. Joint swelling and secondary mechanical allodynia and hyperalgesia were evaluated over 7 days post-CFA. After this period, animals were culled and their blood and synovial fluid samples were collected for analysis of cell populations, cytokine release and thioredoxin reductase (TrxR) activity. Knee joint samples were also collected for histology. SFN reduced joint swelling and damage whilst increasing the recruitment of Ly6C⁺ and Ly6G⁺ cells to CFA-injected joints. SFN-treated animals presented down-regulation of CD11b and CD62L on synovial fluid Ly6G⁺ cells. Synovial fluid samples obtained from CFA-injected joints and plasma samples of SFN-treated mice presented higher levels of IL-6 and increased activity of TrxR, in comparison with controls. These results indicate that SFN reduces knee joint damage by modulating cell activation/migration to the joints, cytokine production and increasing the activity of TrxR, and therefore, may represent an alternative treatment to joint inflammation.

  15. Comparison of chemical-activated luciferase gene expression bioassay and gas chromatography for PCB determination in human serum and follicular fluid.

    PubMed Central

    Pauwels, A; Cenijn, P H; Schepens, P J; Brouwer, A

    2000-01-01

    We assessed exposure to dioxin-like compounds using chemical and bioassay analysis in different matrices in a female population. A total of 106 serum and 9 follicular fluid samples were collected from infertile women attending Centers for Reproductive Medicine in Belgium from 1996 to 1998. Major polychlorinated biphenyl (PCB) congeners were quantified by chemical analysis using gas chromatography with electron-capture detection, and the chemical-activated luciferase gene expression (CALUX) bioassay was used to determine the total dioxin-like toxic equivalence (TEQ) of mixtures of polyhalogenated aromatic hydrocarbons present in body fluids, such as serum and follicular fluid. To the best of our knowledge, this is the first investigation to determine TEQ values by the CALUX bioassay in follicular fluid. The TEQ levels in both matrices are well correlated (r = 0.83, p = 0.02). As the chemical and bioassay analysis executed in this study do not cover the same span of polyhalogenated aromatic hydrocarbons, we did not expect totally correlated results. Moreover, the sample workup and quantification of the analytes differed completely. Nonetheless, the TEQ values in human extracts correlated well with the sum of four major PCB congeners chemically determined in both serum and follicular fluid. These results indicate that the CALUX bioassay may serve as a simple, relatively inexpensive prescreening tool for exposure assessment in epidemiologic surveys. Images Figure 1 Figure 2 PMID:10856030

  16. Genetic legacy of the deep subsurface recorded in the outflow channel of a terrestrial serpentinizing seep (Luzon, the Philippines)

    NASA Astrophysics Data System (ADS)

    Woycheese, K. M.; Meyer-Dombard, D. R.; Cardace, D.; Arcilla, C. A.

    2014-12-01

    The deep subsurface microbial community represents the largest biome on Earth, yet accessing this deep biosphere is challenging. Fluids seep along fractures from aquifers that may support diverse microbial communities, living off hydrogen gas generated by radiolysis, serpentinization, or thermogenic reactions. A serpentinizing seep, emanating fluids as high as pH 11.27, was found to accrete meters-long carbonate terraces in the Zambales ophiolite range (Luzon, the Philippines). Samples were collected at several locations along the Poon Bato (PB) River, focusing primarily on the pools and terraces formed by carbonate rimstone (Figure 1). As serpentinizing fluids are exposed to the atmosphere, dynamic niches are established in surface sediments. We propose that the high pH, reducing, high Ca+2 fluid pool terraces reflect remnants of deep subsurface microbial communities, based on high-throughput 16S rRNA sequencing data. In total, eight samples were collected for environmental DNA analysis. Post-sequence analysis revealed a total of 927126 counts, with an average of 115890.75 counts per sample. Many taxa aligned with cultured representatives of serpentinizing seep-associated taxa, including Bacteroidetes, Clostrida, Chloroflexi, Methylococcales, and Xanthomonadales. Geochemical data indicates an average fluid temperature of 28.9°C, and pH that varies from 9.22-11.27. Total carbon wt.% of solids was highest in a shallow pool shaped by boulders, where calcite precipitation occurred over nearly every surface. Dissolved oxygen (DO%) was highest at PB1 main pool (60%), although a calcite skin had formed along the air-water interface. Dissolved inorganic carbon (DIC) at PB1 main pool was 1.3 ppm, while at PB2 main pool, the DIC was higher (6.0 ppm). The lack of calcite skin may allow more direct access to atmospheric carbon dioxide at PB2. The isotopic value of carbon-13 was depleted at PB1 relative to PB2 (δ13C VPDB -25.4 ‰ versus δ13C VPDB ‰ -17.5, respectively). The DOC concentration at PB1 main pool was 0.3 ppm and 1.15 ppm at PB2. Given the low DIC concentrations at PB1, it is suggested that heterotrophy may dominate over autotrophy in the system. This suggests that the highly reducing, high pH fluids emanating from fluid seeps at Poon Bato influence surface communities via inundation with serpentinizing fluid.

  17. DTS Raw Data Guelph, ON Canada

    DOE Data Explorer

    Thomas Coleman

    2013-07-31

    Unprocessed active distributed temperature sensing (DTS) data from 3 boreholes in the Guelph, ON Canada region. Data from borehole 1 was collected during a fluid injection while data from boreholes 2 and 3 were collected under natural gradient conditions in a lined borehole. The column labels/headers (in the first row) define the time since start of measurement in seconds and the row labels/headers (in the first column) are the object IDs that are defined in the metadata. Each object ID is a sampling location whose exact location is defined in the metadata file. Data in each cell are temperature in Celsius at time and sampling location as defined above.

  18. In Vitro Studies Evaluating Leaching of Mercury from Mine Waste Calcine Using Simulated Human Body Fluids

    PubMed Central

    2010-01-01

    In vitro bioaccessibility (IVBA) studies were carried out on samples of mercury (Hg) mine-waste calcine (roasted Hg ore) by leaching with simulated human body fluids. The objective was to estimate potential human exposure to Hg due to inhalation of airborne calcine particulates and hand-to-mouth ingestion of Hg-bearing calcines. Mine waste calcines collected from Hg mines at Almadén, Spain, and Terlingua, Texas, contain Hg sulfide, elemental Hg, and soluble Hg compounds, which constitute primary ore or compounds formed during Hg retorting. Elevated leachate Hg concentrations were found during calcine leaching using a simulated gastric fluid (as much as 6200 μg of Hg leached/g sample). Elevated Hg concentrations were also found in calcine leachates using a simulated lung fluid (as much as 9200 μg of Hg leached/g), serum-based fluid (as much as 1600 μg of Hg leached/g), and water of pH 5 (as much as 880 μg of Hg leached/g). The leaching capacity of Hg is controlled by calcine mineralogy; thus, calcines containing soluble Hg compounds contain higher leachate Hg concentrations. Results indicate that ingestion or inhalation of Hg mine-waste calcine may lead to increased Hg concentrations in the human body, especially through the ingestion pathway. PMID:20491469

  19. In vitro studies evaluating leaching of mercury from mine waste calcine using simulated human body fluids.

    PubMed

    Gray, John E; Plumlee, Geoffrey S; Morman, Suzette A; Higueras, Pablo L; Crock, James G; Lowers, Heather A; Witten, Mark L

    2010-06-15

    In vitro bioaccessibility (IVBA) studies were carried out on samples of mercury (Hg) mine-waste calcine (roasted Hg ore) by leaching with simulated human body fluids. The objective was to estimate potential human exposure to Hg due to inhalation of airborne calcine particulates and hand-to-mouth ingestion of Hg-bearing calcines. Mine waste calcines collected from Hg mines at Almaden, Spain, and Terlingua, Texas, contain Hg sulfide, elemental Hg, and soluble Hg compounds, which constitute primary ore or compounds formed during Hg retorting. Elevated leachate Hg concentrations were found during calcine leaching using a simulated gastric fluid (as much as 6200 microg of Hg leached/g sample). Elevated Hg concentrations were also found in calcine leachates using a simulated lung fluid (as much as 9200 microg of Hg leached/g), serum-based fluid (as much as 1600 microg of Hg leached/g), and water of pH 5 (as much as 880 microg of Hg leached/g). The leaching capacity of Hg is controlled by calcine mineralogy; thus, calcines containing soluble Hg compounds contain higher leachate Hg concentrations. Results indicate that ingestion or inhalation of Hg mine-waste calcine may lead to increased Hg concentrations in the human body, especially through the ingestion pathway.

  20. In vitro studies evaluating leaching of mercury from mine waste calcine using simulated human body fluids

    USGS Publications Warehouse

    Gray, John E.; Plumlee, Geoffrey S.; Morman, Suzette A.; Higueras, Pablo L.; Crock, James G.; Lowers, Heather A.; Witten, Mark L.

    2010-01-01

    In vitro bioaccessibility (IVBA) studies were carried out on samples of mercury (Hg) mine-waste calcine (roasted Hg ore) by leaching with simulated human body fluids. The objective was to estimate potential human exposure to Hg due to inhalation of airborne calcine particulates and hand-to-mouth ingestion of Hg-bearing calcines. Mine waste calcines collected from Hg mines at Almadén, Spain, and Terlingua, Texas, contain Hg sulfide, elemental Hg, and soluble Hg compounds, which constitute primary ore or compounds formed during Hg retorting. Elevated leachate Hg concentrations were found during calcine leaching using a simulated gastric fluid (as much as 6200 μg of Hg leached/g sample). Elevated Hg concentrations were also found in calcine leachates using a simulated lung fluid (as much as 9200 μg of Hg leached/g), serum-based fluid (as much as 1600 μg of Hg leached/g), and water of pH 5 (as much as 880 μg of Hg leached/g). The leaching capacity of Hg is controlled by calcine mineralogy; thus, calcines containing soluble Hg compounds contain higher leachate Hg concentrations. Results indicate that ingestion or inhalation of Hg mine-waste calcine may lead to increased Hg concentrations in the human body, especially through the ingestion pathway.

  1. Biogeochemical characteristics of Kuan-Tzu-Ling, Chung-Lun and Bao-Lai hot springs in southern Taiwan.

    PubMed

    Maity, Jyoti Prakash; Liu, Chia-Chuan; Nath, Bibhash; Bundschuh, Jochen; Kar, Sandeep; Jean, Jiin-Shuh; Bhattacharya, Prosun; Liu, Jiann-Hong; Atla, Shashi B; Chen, Chien-Yen

    2011-01-01

    Hot springs are the important natural sources of geothermally heated groundwater from the Earth's crust. Kuan-Tzu-Ling (KTL), Chung-Lun (CL) and Bao-Lai (BL) are well-known hot springs in southern Taiwan. Fluid and mud (sediments) samples were collected from the eruption points of three hot springs for detailed biogeochemical characterization. The fluid sample displays relatively high concentrations of Na(+) and Cl(-) compared with K(+), Mg(2+), Ca(2+), NO(2) (-), and SO(4) (2-), suggesting a possible marine origin. The concentrations of Fe, Cr, Mn, Ni, V and Zn were significantly higher in the mud sediments compared with fluids, whereas high concentrations of As, Ba, Cu, Se, Sr and Rb were observed in the fluids. This suggests that electronegative elements were released during sediment-water interactions. High As concentration in the fluids was observed to be associated with low redox (Eh) conditions. The FTIR spectra of the humic acid fractions of the sediments showed the presence of possible functional groups of secondary amines, ureas, urethanesm (amide), and silicon. The sulfate-reducing deltaproteobacterium 99% similar to Desulfovibrio psychrotolerans (GU329907) were rich in the CL hot spring while mesophilic, proteolytic, thiosulfate- and sulfur-reducing bacterium that 99% similar to Clostridium sulfidigenes (GU329908) were rich in the BL hot spring.

  2. Investigation of Tank 241-AN-101 Floating Solids

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kraft, Douglas P.; Meznarich, H. K.

    Tank 241-AN-101 is the receiver tank for retrieval of several C-Farms waste tanks, including Tanks 241-C-102 and 241-C-111. Tank 241 C 111 received first-cycle decontamination waste from the bismuth phosphate process and Plutonium and Uranium Extraction cladding waste, as well as hydraulic fluid. Three grab samples, 1AN-16-01, 1AN-16-01A, and 1AN-16-01B, were collected at the surface of Tank 241-AN-101 on April 25, 2016, after Tank 241-C-111 retrieval was completed. Floating solids were observed in the three grab samples in the 11A hot cell after the samples were received at the 222-S Laboratory. Routine chemical analyses, solid phase characterization on the floatingmore » and settled solids, semivolatile organic analysis mainly on the aqueous phase for identification of degradation products of hydraulic fluids were performed. Investigation of the floating solids is reported.« less

  3. Assessment of extracellular dehydration using saliva osmolality.

    PubMed

    Ely, Brett R; Cheuvront, Samuel N; Kenefick, Robert W; Spitz, Marissa G; Heavens, Kristen R; Walsh, Neil P; Sawka, Michael N

    2014-01-01

    When substantial solute losses accompany body water an isotonic hypovolemia (extracellular dehydration) results. The potential for using blood or urine to assess extracellular dehydration is generally poor, but saliva is not a simple ultra-filtrate of plasma and the autonomic regulation of salivary gland function suggests the possibility that saliva osmolality (Sosm) may afford detection of extracellular dehydration via the influence of volume-mediated factors. This study aimed to evaluate the assessment of extracellular dehydration using Sosm. In addition, two common saliva collection methods and their effects on Sosm were compared. Blood, urine, and saliva samples were collected in 24 healthy volunteers during paired euhydration and dehydration trials. Furosemide administration and 12 h fluid restriction were used to produce extracellular dehydration. Expectoration and salivette collection methods were compared in a separate group of eight euhydrated volunteers. All comparisons were made using paired t-tests. The diagnostic potential of body fluids was additionally evaluated. Dehydration (3.1 ± 0.5% loss of body mass) decreased PV (-0.49 ± 0.12 L; -15.12 ± 3.94% change), but Sosm changes were marginal (<10 mmol/kg) and weakly correlated with changes in absolute or relative PV losses. Overall diagnostic accuracy was poor (AUC = 0.77-0.78) for all body fluids evaluated. Strong agreement was observed between Sosm methods (Expectoration: 61 ± 10 mmol/kg, Salivette: 61 ± 8 mmol/kg, p > 0.05). Extracelluar dehydration was not detectable using plasma, urine, or saliva measures. Salivette and expectoration sampling methods produced similar, consistent results for Sosm, suggesting no methodological influence on Sosm.

  4. Biomimetic model systems of rigid hair beds: Part I - Theory

    NASA Astrophysics Data System (ADS)

    Hood, Kaitlyn; Jammalamadaka, Mani S. S.; Hosoi, Anette

    2017-11-01

    Crustaceans - such as lobsters, crabs, and stomapods - have hairy appendages that they use to recognize and track odorants in the surrounding fluid. An array of rigid hairs impedes flow at different rates depending on the spacing between hairs and the Reynolds number, Re. At larger Reynolds numbers (Re >1), fluid travels through the hairs rather than around them, a phenomenon called leakiness. Crustaceans flick their appendages at different speeds in order to manipulate the leakiness between the hairs, allowing the hairs to either detect odors in a sample of fluid or collect a new sample. A single hair can be represented as a slender body attached at one end to a wall. Using both slender body theory and numerical methods, we observe that there is a region of flow around the hair that speeds up relative to the unobstructed flow. As the Reynolds number increases, this fast flow region moves closer to the hair. Using this model, we predict that an array of hairs can be engineered to have a desired leakiness profile.

  5. Adherence to diet and fluid restriction of individuals on hemodialysis treatment and affecting factors in Turkey.

    PubMed

    Efe, Dilek; Kocaöz, Semra

    2015-04-01

    This study was conducted to determine adherence to diet and fluid restriction in hemodialysis-treated individuals and the affecting factors in Turkey. This descriptive study was conducted between 15 October 2010 and 15 January 2011 in subjects who voluntarily agreed to participate in the study from three dialysis centers in a city located in the Central Anatolia Region of Turkey. One hundred and twenty-one individuals treated with hemodialysis made up the study sample. The data were collected using a questionnaire consisting of 41 questions and the Dialysis Diet and Fluid Non-adherence Questionnaire. The data were evaluated with percentage, median, Mann-Whitney U-test, Kruskal-Wallis test, Student's t-test in independent samples and Spearman's rank correlation coefficient. The authors found that 98.3% of the individuals experienced non-adherence to diet and 95.0% with fluid restriction. The authors found a weak and negative relationship between calcium levels and non-adherence to fluid restriction, a weak relationship between phosphorus levels and diet non-adherence frequency and degree and the fluid non-adherence frequency scores, and a moderate positive relationship between phosphorus levels and fluid restriction non-adherence degree scores (P < 0.05). Based on these results, regular training and information regarding diet and fluid restriction must be provided to individuals aged 21-35 years with no one in the family to help with their care, those who consumed salted food, or had interdialytic weight gain of 4.5 kg or more. © 2014 The Authors. Japan Journal of Nursing Science © 2014 Japan Academy of Nursing Science.

  6. Combined endoscopy, aspiration, and biopsy analysis for identifying infectious colitis in patients with ileocecal ulcers.

    PubMed

    Nagata, Naoyoshi; Shimbo, Takuro; Sekine, Katsunori; Tanaka, Shouhei; Niikura, Ryota; Mezaki, Kazuhisa; Morino, Eriko; Yazaki, Hirohisa; Igari, Toru; Ohmagari, Norio; Akiyama, Junichi; Oka, Shinichi; Uemura, Naomi

    2013-06-01

    The ileocecal area is commonly involved in infection and inflammatory colonic diseases, but differential diagnosis can be difficult. We identified definitive endoscopic findings and a sample collection method for diagnosing infectious colitis. In a retrospective study, we analyzed data on 128 patients with ileocecal ulcer who underwent colonoscopy from 2007-2011 at the National Center for Global Health and Medicine in Tokyo, Japan. We collected information on location, size, number, and distinctive endoscopic findings and estimated diagnostic odds ratios (ORs). The sensitivities of microscopy, culture, polymerase chain reaction, and histologic methods in identifying patients with infection were compared with those of standard stool, endoscopic aspirated intestinal fluid, or biopsy analyses. Of the 128 patients, 100 had infections, and 28 had Crohn's disease, Behçet's disease, or other inflammatory diseases. Predictive endoscopic findings were as follows: for amebiasis of the cecum (OR, 17.8), with exudates (OR, 13.9) and round-shaped ulcer (OR, 5.77); for tuberculosis (TB) with transverse-shaped ulcer (OR, 175), scar (OR, 34.6), linear-shaped ulcer (OR, 23.9), or ≥10 mm (OR, 14.0); for cytomegalovirus with round-shaped ulcer (OR, 4.09); and for Campylobacter with cecal valve lesion (OR, 58.3) or ≥10 mm (OR, 10.4). The sensitivity of endoscopic sample collection was significantly higher than that of standard stool sample collection for the diagnosis of amebiasis, TB, non-TB mycobacteria, and other bacteria (P < .05). The methods that detected infection with the highest levels of sensitivity were biopsy with histology for amebiasis, biopsy with culture for TB, biopsy with polymerase chain reaction for cytomegalovirus, and aspiration of intestinal fluid with culture for Campylobacter. Combining results from endoscopic analysis with appropriate sample collection and pathogen detection methods enables infectious colitis to be differentiated from other noninfectious colonic diseases. Copyright © 2013 AGA Institute. Published by Elsevier Inc. All rights reserved.

  7. Development of a transcutaneous blood-constituent monitoring method using a suction effusion fluid collection technique and an ion-sensitive field-effect transistor glucose sensor.

    PubMed

    Ito, N; Kayashima, S; Kimura, J; Kuriyama, T; Arai, T; Kikuchi, M; Nagata, N

    1994-05-01

    The paper describes a method for the transcutaneous monitoring of blood constituents. It combines the use of a suction effusion fluid (SEF) collecting technique with a silicon on sapphire/ion-sensitive field-effect transistor (SOS/ISFET) biosensor. SEF is directly collected by a weak evacuation through skin from which the stratum corneum has been removed. An SEF collecting cell with a stainless-steel mesh at the bottom is kept in a weak vacuum condition, and SEF is sucked up through the mesh and deposited in a reservoir above. An ISFET glucose sensor is able to detect glucose concentrations in very small SEF samples through the use of two small ISFETs and an immobilised enzyme membrane. The reliability of transcutaneously obtained SEF was first confirmed in an experiment using rabbits. A clinical analyser was used to determine levels of glucose, urea nitrogen and creatinine in SEF obtained transcutaneously; these results are compared with results obtained by the same analyser directly from sera. The ISFET glucose sensor was successfully tested on human subjects for the monitoring of blood glucose levels. During these tests, glucose level changes in the SEF followed actual blood glucose level changes with a slight time delay. Results suggest the feasibility of non-invasive, transcutaneous monitoring of low molecular weight substances in the blood without the use of ordinary blood sampling.

  8. Development of a magnetic bead-based method for the collection of circulating extracellular vesicles.

    PubMed

    Shih, Chun-Liang; Chong, Kowit-Yu; Hsu, Shih-Che; Chien, Hsin-Jung; Ma, Ching-Ting; Chang, John Wen-Cheng; Yu, Chia-Jung; Chiou, Chiuan-Chian

    2016-01-25

    Cells release different types of extracellular vesicles (EVs). These EVs contain biomolecules, including proteins and nucleic acids, from their parent cells, which can be useful for diagnostic applications. The aim of this study was to develop a convenient procedure to collect circulating EVs with detectable mRNA or other biomolecules. Magnetic beads coated with annexin A5 (ANX-beads), which bound to phosphatidylserine moieties on the surfaces of most EVs, were tested for their ability to capture induced apoptotic bodies in vitro and other phosphatidylserine-presenting vesicles in body fluids. Our results show that up to 60% of induced apoptotic bodies could be captured by the ANX-beads. The vesicles captured from cultured media or plasma contained amplifiable RNA. Suitable blood samples for EV collection included EDTA-plasma and serum but not heparin-plasma. In addition, EVs in plasma were labile to freeze-and-thaw cycles. In rodents xenografted with human cancer cells, tumor-derived mRNA could be detected in EVs captured from serum samples. Active proteins could be detected in EVs captured from ascites but not from plasma. In conclusion, we have developed a magnetic bead-based procedure for the collection of EVs from body fluids and proved that captured EVs contain biomolecules from their parent cells, and therefore have great potential for disease diagnosis. Copyright © 2015 Elsevier B.V. All rights reserved.

  9. Fluid sampling system for a nuclear reactor

    DOEpatents

    Lau, Louis K.; Alper, Naum I.

    1994-01-01

    A system of extracting fluid samples, either liquid or gas, from the interior of a nuclear reactor containment utilizes a jet pump. To extract the sample fluid, a nonradioactive motive fluid is forced through the inlet and discharge ports of a jet pump located outside the containment, creating a suction that draws the sample fluid from the containment through a sample conduit connected to the pump suction port. The mixture of motive fluid and sample fluid is discharged through a return conduit to the interior of the containment. The jet pump and means for removing a portion of the sample fluid from the sample conduit can be located in a shielded sample grab station located next to the containment. A non-nuclear grade active pump can be located outside the grab sampling station and the containment to pump the nonradioactive motive fluid through the jet pump.

  10. Fluid sampling system for a nuclear reactor

    DOEpatents

    Lau, L.K.; Alper, N.I.

    1994-11-22

    A system of extracting fluid samples, either liquid or gas, from the interior of a nuclear reactor containment utilizes a jet pump. To extract the sample fluid, a nonradioactive motive fluid is forced through the inlet and discharge ports of a jet pump located outside the containment, creating a suction that draws the sample fluid from the containment through a sample conduit connected to the pump suction port. The mixture of motive fluid and sample fluid is discharged through a return conduit to the interior of the containment. The jet pump and means for removing a portion of the sample fluid from the sample conduit can be located in a shielded sample grab station located next to the containment. A non-nuclear grade active pump can be located outside the grab sampling station and the containment to pump the nonradioactive motive fluid through the jet pump. 1 fig.

  11. Metal Complexation in Xylem Fluid 1

    PubMed Central

    White, Michael C.; Decker, A. Morris; Chaney, Rufus L.

    1981-01-01

    Xylem fluid was analyzed for numerous solutes to characterize chemically the sap as a medium for forming and transporting metal complexes. The stem exudate was collected hourly for 8 hours from topped 31-day-old soybean (Glycine max L. Merr.) and 46-day-old tomato (Lycopersicon esculentum Mill.) plants grown in normal (0.5 micromolar) and Za-phytotoxic nutrient solutions. Soybean plants were grown in the normal and high-Zn solutions for 24 days; tomato plants were grown for 32 days. The exudate was analyzed for seven organic acids, 22 amino acids, eight inorganic solutes, apparent ionic strength, and pH. Significant changes in many solutes occurred over the 8-hour sampling period. These fluctuations depended on plant species, individual solute, and Zn treatment, and demonstrated that extrapolation of xylem-fluid analyses to whole-plant xylem sap is valid only for sap samples collected shortly after topping a plant. Exudate pH decreased over the 8-hour period for both species; exudate ionic strength increased for tomato and decreased for soybean. At the normal-Zn treatment (0 to 1 hour), the highest acid micromolar concentrations in soybean exudate were: asparagine, 2,583; citric, 1,706; malic, 890; and malonic, 264. Under the same conditions, the highest acid micromolar concentrations in tomato exudate were: maleic, 1,206; malic, 628; glutamine, 522; citric, 301; and asparagine, 242. Cysteine and methionine were above detection limits only in soybean exudate. Zinc phytotoxicity caused significant changes in many solutes. The analyses reported here provide a comprehensive data base for further studies on metal-complex equilibria in xylem fluid. PMID:16661664

  12. Disposition of isoflupredone acetate in plasma, urine and synovial fluid following intra-articular administration to exercised Thoroughbred horses.

    PubMed

    Knych, Heather K; Harrison, Linda M; White, Alexandria; McKemie, Daniel S

    2016-01-01

    The use of isoflupredone acetate in performance horses and the scarcity of published pharmacokinetic data necessitate further study. The objective of the current study was to describe the plasma pharmacokinetics of isoflupredone acetate as well as time-related urine and synovial fluid concentrations following intra-articular administration to horses. Twelve racing-fit adult Thoroughbred horses received a single intra-articular administration (8 mg) of isoflupredone acetate into the right antebrachiocarpal joint. Blood, urine and synovial fluid samples were collected prior to and at various times up to 28 days post drug administration. All samples were analyzed using liquid chromatography-Mass Spectrometry. Plasma data were analyzed using a population pharmacokinetic compartmental model. Maximum measured plasma isoflupredone concentrations were 1.76 ± 0.526 ng/mL at 4.0 ± 1.31 h and 1.63 ± 0.243 ng/mL at 4.75 ± 0.5 h, respectively, for horses that had synovial fluid collected and for those that did not. The plasma beta half-life was 24.2 h. Isoflupredone concentrations were below the limit of detection in all horses by 48 h and 7 days in plasma and urine, respectively. Isoflupredone was detected in the right antebrachiocarpal and middle carpal joints for 8.38 ± 5.21 and 2.38 ± 0.52 days, respectively. Results of this study provide information that can be used to regulate the use of intra-articular isoflupredone in the horse. Copyright © 2015 John Wiley & Sons, Ltd.

  13. Systematics of Alkali Metals in Pore Fluids from Serpentinite Mud Volcanoes: IODP Expedition 366

    NASA Astrophysics Data System (ADS)

    Wheat, C. G.; Ryan, J.; Menzies, C. D.; Price, R. E.; Sissmann, O.

    2017-12-01

    IODP Expedition 366 focused, in part, on the study of geo­chemical cycling, matrix alteration, material and fluid transport, and deep biosphere processes within the subduction channel in the Mariana forearc. This was accomplished through integrated sampling of summit and flank regions of three active serpentinite mud volcanoes (Yinazao (Blue Moon), Asùt Tesoro (Big Blue), and Fantangisña (Celestial) Seamounts). These edifices present a transect of depths to the Pacific Plate, allowing one to characterize thermal, pressure and compositional effects on processes that are associated with the formation of serpentinite mud volcanoes and continued activity below and within them. Previous coring on ODP Legs 125 and 195 at two other serpentinite mud volcanoes (Conical and South Chamorro Seamounts) and piston, gravity, and push cores from several other Mariana serpentinite mud volcanoes add to this transect of sites where deep-sourced material is discharged at the seafloor. Pore waters (149 samples) were squeezed from serpentinite materials to determine the composition of deep-sourced fluid and to assess the character, extent, and effect of diagenetic reactions and mixing with seawater on the flanks of the seamounts as the serpentinite matrix weathers. In addition two Water Sampler Temperature Tool (WSTP) fluid samples were collected within two of the cased boreholes, each with at least 30 m of screened casing that allows formations fluids to discharge into the borehole. Shipboard results for Na and K record marked seamount-to-seamount differences in upwelling summit fluids, and complex systematics in fluids obtained from flank sites. Here we report new shore-based Rb and Cs measurements, two elements that have been used to constrain the temperature of the deep-sourced fluid. Data are consistent with earlier coring and drilling expeditions, resulting in systematic changes with depth (and by inference temperature) to the subduction channel.

  14. Point-of-care oral-based diagnostics

    PubMed Central

    Hart, RW; Mauk, MG; Liu, C; Qiu, X; Thompson, JA; Chen, D; Malamud, D; Abrams, WR; Bau, HH

    2014-01-01

    Many of the target molecules that reside in blood are also present in oral fluids, albeit at lower concentrations. Oral fluids are, however, relatively easy and safe to collect without the need for specialized equipment and training. Thus, oral fluids provide convenient samples for medical diagnostics. Recent advances in lab-on-a-chip technologies have made minute, fully integrated diagnostic systems practical for an assortment of point-of-care tests. Such systems can perform either immunoassays or molecular diagnostics outside centralized laboratories within time periods ranging from minutes to an hour. The article briefly reviews recent advances in devices for point-of-care testing with a focus on work that has been carried out by the authors as part of a NIH program. PMID:21521419

  15. Adaption of synchronously scanned luminescence spectroscopy to organic-rich fluid inclusion microanalysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Musgrave, J.A.; Carey, R.G.; Janecky, D.R.

    1994-06-01

    The instrumentation, the luminescence microprobe, and synchronously scanned luminescence spectroscopy technique described here can be used to classify microliter quantities of oil such as those in fluid inclusions in cements from petroleum reservoirs. It is primarily constructed to obtain synchronously scanned luminescence spectra from microscopic sized samples to characterize the organic classes of compounds that predominate. At present no other technique can so readily analyze a single oil-bearing fluid inclusion. The data collected from the technique are pertinent to evaluating systems and providing quantitative data for solving problems in oil migration and maturation determinations, oil-to-oil and oil-to-source correlations, oil degradation,more » and episodes and chemistry of cementation.« less

  16. Fluid intelligence and psychiatric disorders in a population representative sample of US adolescents

    PubMed Central

    Keyes, Katherine M.; Platt, Jonathan; Kaufman, Alan S.; McLaughlin, Katie A.

    2017-01-01

    Importance Despite long-standing interest in the association of psychiatric disorders with intelligence, few population-based studies of psychiatric disorders have assessed intelligence. Objectives To investigate the association of fluid intelligence with past-year and lifetime psychiatric disorders, disorder age-of-onset, and disorder severity in a nationally-representative sample of U.S. adolescents. Design Dual-frame national sample of adolescents ascertained from schools and households from the National Comorbidity Survey Replication-Adolescent Supplement, collected 2001–2004. Setting Face-to-face household interviews with adolescents and questionnaires from parents. Participants The sample included 10,073 adolescents with valid data on fluid intelligence. Exposures DSM-IV mental disorders were assessed with the World Health Organization Composite International Diagnostic Interview, and included a broad range of fear, distress, behavior, substance use and other disorders. Disorder severity was measured with the Sheehan Disability Scale. Main Outcomes Fluid intelligence quotient (IQ) measured with Kaufman Brief Intelligence Test, normed within the sample by six-month age groups. Results Lower mean IQ was observed among adolescents with past-year bipolar disorder (predicted Mean [M]=94.2, p<0.01), attention-deficit/hyperactivity disorder (M=96.3, p<0.01), oppositional defiant disorder (M=97.3, p<0.01), conduct disorder (M=97.1, p=0.02) substance disorders (M=96.5–97.6, p=0.02 to <0.01) and specific phobia (M=97.1, p<0.01) after adjustment for a wide range of potential confounders. Intelligence was not associated with post-traumatic stress disorder, eating disorders, and anxiety disorders other than specific phobia, and was positively associated with major depression. Associations of fluid intelligence with lifetime disorders that had remitted were attenuated compared to past-year disorders, with the exception of separation anxiety disorder. Across disorders, higher disorder severity was associated with lower fluid intelligence. Conclusions Numerous psychiatric disorders are associated with reductions in fluid intelligence; associations are generally small in magnitude. Stronger associations of current than past disorders with intelligence suggest that active symptoms of psychopathology interfere with cognitive functioning, although longitudinal studies are needed to determine the extent to which changes in fluid intelligence precede or follow the onset of psychiatric disorders. Early identification and treatment of children with mental disorders in school settings is critical to promote academic achievement and long-term success. PMID:28030746

  17. Clearance of bile and trypsin in rat lungs following aspiration of human gastric fluid

    PubMed Central

    Leung, Jason H.; Chang, Jui-Chih; Foltz, Emily; Bell, Sadé M.; Pi, Cinthia; Azad, Sassan; Everett, Mary Lou; Holzknecht, Zoie E.; Sanders, Nathan L.; Parker, William; Davis, R. Duane; Keshavjee, Shaf; Lin, Shu S.

    2016-01-01

    ABSTRACT Purpose: In the clinical setting, there is no reliable tool for diagnosing gastric aspiration. A potential way of diagnosing gastric fluid aspiration entails bronchoalveolar lavage (BAL) with subsequent examination of the BAL fluid for gastric fluid components that are exogenous to the lungs. The objective of this study was to determine the longevity of the gastric fluid components bile and trypsin in the lung, in order to provide an estimate of the time frame in which assessment of these components in the BAL might effectively be used as a measure of aspiration. Materials and Methods: Human gastric fluid (0.5 mg/kg) was infused in the right lung of intubated male Fischer 344 rats (n = 30). Animals were sacrificed at specified times following the experimentally induced aspiration, and bronchoalveolar lavage fluid (BALF) was collected. Bile concentrations were analyzed by an enzyme-linked chromatogenic method, and the concentration of trypsin was quantified using an ELISA. Data were analyzed using non-linear regression and a one-phase decay equation. Results: In this experimental model, the half-life of bile was 9.3 hours (r 2 = 0.81), and the half-life of trypsin was 9.0 hours (r 2 = 0.68). Conclusions: The half-lives of bile and trypsin in the rodent aspiration model suggest that the ability to detect aspiration may be limited to a few days post-aspiration. If studies using rats are any indication, it may be most effective to collect BAL samples within the first 24 hours of suspected aspiration events in order to detect aspiration. PMID:26873328

  18. Clearance of bile and trypsin in rat lungs following aspiration of human gastric fluid.

    PubMed

    Leung, Jason H; Chang, Jui-Chih; Foltz, Emily; Bell, Sadé M; Pi, Cinthia; Azad, Sassan; Everett, Mary Lou; Holzknecht, Zoie E; Sanders, Nathan L; Parker, William; Davis, R Duane; Keshavjee, Shaf; Lin, Shu S

    2016-01-01

    In the clinical setting, there is no reliable tool for diagnosing gastric aspiration. A potential way of diagnosing gastric fluid aspiration entails bronchoalveolar lavage (BAL) with subsequent examination of the BAL fluid for gastric fluid components that are exogenous to the lungs. The objective of this study was to determine the longevity of the gastric fluid components bile and trypsin in the lung, in order to provide an estimate of the time frame in which assessment of these components in the BAL might effectively be used as a measure of aspiration. Human gastric fluid (0.5 mg/kg) was infused in the right lung of intubated male Fischer 344 rats (n = 30). Animals were sacrificed at specified times following the experimentally induced aspiration, and bronchoalveolar lavage fluid (BALF) was collected. Bile concentrations were analyzed by an enzyme-linked chromatogenic method, and the concentration of trypsin was quantified using an ELISA. Data were analyzed using non-linear regression and a one-phase decay equation. In this experimental model, the half-life of bile was 9.3 hours (r(2) = 0.81), and the half-life of trypsin was 9.0 hours (r(2) = 0.68). The half-lives of bile and trypsin in the rodent aspiration model suggest that the ability to detect aspiration may be limited to a few days post-aspiration. If studies using rats are any indication, it may be most effective to collect BAL samples within the first 24 hours of suspected aspiration events in order to detect aspiration.

  19. Changes in blood flow and cellular metabolism at a myofascial trigger point with trigger point release (ischemic compression): a proof-of-principle pilot study

    PubMed Central

    Moraska, Albert F.; Hickner, Robert C.; Kohrt, Wendy M.; Brewer, Alan

    2012-01-01

    Objective To demonstrate proof-of-principle measurement for physiological change within an active myofascial trigger point (MTrP) undergoing trigger point release (ischemic compression). Design Interstitial fluid was sampled continuously at a trigger point before and after intervention. Setting A biomedical research clinic at a university hospital. Participants Two subjects from a pain clinic presenting with chronic headache pain. Interventions A single microdialysis catheter was inserted into an active MTrP of the upper trapezius to allow for continuous sampling of interstitial fluid before and after application of trigger point therapy by a massage therapist. Main Outcome Measures Procedural success, pain tolerance, feasibility of intervention during sample collection, determination of physiologically relevant values for local blood flow, as well as glucose and lactate concentrations. Results Both patients tolerated the microdialysis probe insertion into the MTrP and treatment intervention without complication. Glucose and lactate concentrations were measured in the physiological range. Following intervention, a sustained increase in lactate was noted for both subjects. Conclusions Identifying physiological constituents of MTrP’s following intervention is an important step toward understanding pathophysiology and resolution of myofascial pain. The present study forwards that aim by showing proof-of-concept for collection of interstitial fluid from an MTrP before and after intervention can be accomplished using microdialysis, thus providing methodological insight toward treatment mechanism and pain resolution. Of the biomarkers measured in this study, lactate may be the most relevant for detection and treatment of abnormalities in the MTrP. PMID:22975226

  20. A dynamic microbial community with high functional redundancy inhabits the cold, oxic subseafloor aquifer.

    PubMed

    Tully, Benjamin J; Wheat, C Geoff; Glazer, Brain T; Huber, Julie A

    2018-01-01

    The rock-hosted subseafloor crustal aquifer harbors a reservoir of microbial life that may influence global marine biogeochemical cycles. Here we utilized metagenomic libraries of crustal fluid samples from North Pond, located on the flanks of the Mid-Atlantic Ridge, a site with cold, oxic subseafloor fluid circulation within the upper basement to query microbial diversity. Twenty-one samples were collected during a 2-year period to examine potential microbial metabolism and community dynamics. We observed minor changes in the geochemical signatures over the 2 years, yet the microbial community present in the crustal fluids underwent large shifts in the dominant taxonomic groups. An analysis of 195 metagenome-assembled genomes (MAGs) were generated from the data set and revealed a connection between litho- and autotrophic processes, linking carbon fixation to the oxidation of sulfide, sulfur, thiosulfate, hydrogen, and ferrous iron in members of the Proteobacteria, specifically the Alpha-, Gamma- and Zetaproteobacteria, the Epsilonbacteraeota and the Planctomycetes. Despite oxic conditions, analysis of the MAGs indicated that members of the microbial community were poised to exploit hypoxic or anoxic conditions through the use of microaerobic cytochromes, such as cbb 3 - and bd-type cytochromes, and alternative electron acceptors, like nitrate and sulfate. Temporal and spatial trends from the MAGs revealed a high degree of functional redundancy that did not correlate with the shifting microbial community membership, suggesting functional stability in mediating subseafloor biogeochemical cycles. Collectively, the repeated sampling at multiple sites, together with the successful binning of hundreds of genomes, provides an unprecedented data set for investigation of microbial communities in the cold, oxic crustal aquifer.

  1. Acetylcholine Release in the Hippocampus and Striatum during Place and Response Training

    ERIC Educational Resources Information Center

    Pych, Jason C.; Chang, Qing; Colon-Rivera, Cynthia; Haag, Renee; Gold, Paul E.

    2005-01-01

    These experiments examined the release of acetylcholine in the hippocampus and striatum when rats were trained, within single sessions, on place or response versions of food-rewarded mazes. Microdialysis samples of extra-cellular fluid were collected from the hippocampus and striatum at 5-min increments before, during, and after training. These…

  2. Levels of lipocalin-2 in crevicular fluid and tear fluid in chronic periodontitis and obesity subjects.

    PubMed

    Pradeep, Avani Raju; Nagpal, Kanika; Karvekar, Shruti; Patnaik, Kaushik

    2016-11-01

    Lipocalin-2, a 25 kDa secretory glycoprotein, was first found in the neutrophilic granules of humans and in mouse kidney cells. It has been shown to have an important role in inflammation. The aim of this study was to determine the levels of lipocalin-2 in gingival crevicular fluid and tear fluid in patients with obesity and chronic periodontitis. A total of 40 subjects in the age group 25-40 years were divided into four groups based on probing depth, gingival index, clinical attachment level, body mass index, and radiographic evidence of bone loss. The groups were: nonobese healthy group; obese healthy group; nonobese chronic periodontitis group; obese chronic periodontitis group Gingival crevicular fluid and tear fluid samples were collected on the subsequent day. There was an increase in lipocalin-2 levels from group 1 to group 4 (with the nonobese healthy group showing the least levels and obese chronic periodontitis group showing the highest levels) in both gingival crevicular fluid and tear fluid. Lipocalin-2 may be an important inflammatory marker that may help link obesity and chronic periodontitis. © 2015 Wiley Publishing Asia Pty Ltd.

  3. Design considerations of a hollow microneedle-optofluidic biosensing platform incorporating enzyme-linked assays

    NASA Astrophysics Data System (ADS)

    Ranamukhaarachchi, Sahan A.; Padeste, Celestino; Häfeli, Urs O.; Stoeber, Boris; Cadarso, Victor J.

    2018-02-01

    A hollow metallic microneedle is integrated with microfluidics and photonic components to form a microneedle-optofluidic biosensor suitable for therapeutic drug monitoring (TDM) in biological fluids, like interstitial fluid, that can be collected in a painless and minimally-invasive manner. The microneedle inner lumen surface is bio-functionalized to trap and bind target analytes on-site in a sample volume as small as 0.6 nl, and houses an enzyme-linked assay on its 0.06 mm2 wall. The optofluidic components are designed to rapidly quantify target analytes present in the sample and collected in the microneedle using a simple and sensitive absorbance scheme. This contribution describes how the biosensor components were optimized to detect in vitro streptavidin-horseradish peroxidase (Sav-HRP) as a model analyte over a large detection range (0-7.21 µM) and a very low limit of detection (60.2 nM). This biosensor utilizes the lowest analyte volume reported for TDM with microneedle technology, and presents significant avenues to improve current TDM methods for patients, by potentially eliminating blood draws for several drug candidates.

  4. Concentration of Donepezil in the Cerebrospinal Fluid of AD Patients: Evaluation of Dosage Sufficiency in Standard Treatment Strategy.

    PubMed

    Valis, Martin; Masopust, Jiri; Vysata, Oldrich; Hort, Jakub; Dolezal, Rafael; Tomek, Jiri; Misik, Jan; Kuca, Kamil; Karasova, Jana Zdarova

    2017-01-01

    Although some studies have described the pharmacokinetics and pharmacodynamics of donepezil in the peripheral compartment, studies focused on drug transport across the blood-brain barrier are still very rare. To our knowledge, the fluctuation in the cerebrospinal fluid concentration of donepezil after administration of the drug has not been described in the literature so far. We recruited 16 patients regularly taking a standard therapeutic dose of donepezil (10 mg per day). All patients (Caucasian race) were treated for at least three months with a stable dose of 10 mg per day prior to sample collection. Patients were divided into two groups depending on the time of plasma and cerebrospinal fluid sampling: 12 h (n = 9; 4 M/5F aged 78.68 ± 7.35 years) and 24 h (n = 7; 3 M/4F aged 77.14 ± 5.87 years) after donepezil administration. The cerebrospinal fluid sample was collected by standard lumbar puncture technique using a single-use traumatic needle. The samples were analysed on an Agilent 1260 Series liquid chromatograph comprising a degasser, a quaternary pump, a light-tight autosampler unit set, a thermostated column compartment, and a UV/VIS detector. Agilent ChemStation software, the statistical software Prism4, version 5.0 (GraphPad Software, USA), and IBM ® SPSS ® Statistics were used for the analysis of the results. The difference in plasma concentration of donepezil after 12 h (mean ± SEM; 39.99 ± 5.90 ng/ml) and after 24 h (29.38 ± 1.71 ng/ml) was nonsignificant. In contrast, the donepezil concentration in the cerebrospinal fluid was significantly higher in the 24-h interval (7.54 ± 0.55 ng/ml) compared with the 12-h interval (5.19 ± 0.83 ng/ml, which is ~70 % based on mean cerebrospinal fluid values). Based on these data, it is plausible to predict that donepezil might produce a stronger AChE inhibition in the brain at 24 h compared with 12 h following the administration. This information may help physicians individually adjust the time of drug administration in the patients according to time course of the disease symptoms.

  5. Blood glucose level reconstruction as a function of transcapillary glucose transport.

    PubMed

    Koutny, Tomas

    2014-10-01

    A diabetic patient occasionally undergoes a detailed monitoring of their glucose levels. Over the course of a few days, a monitoring system provides a detailed track of their interstitial fluid glucose levels measured in their subcutaneous tissue. A discrepancy in the blood and interstitial fluid glucose levels is unimportant because the blood glucose levels are not measured continuously. Approximately five blood glucose level samples are taken per day, and the interstitial fluid glucose level is usually measured every 5min. An increased frequency of blood glucose level sampling would cause discomfort for the patient; thus, there is a need for methods to estimate blood glucose levels from the glucose levels measured in subcutaneous tissue. The Steil-Rebrin model is widely used to describe the relationship between blood and interstitial fluid glucose dynamics. However, we measured glucose level patterns for which the Steil-Rebrin model does not hold. Therefore, we based our research on a different model that relates present blood and interstitial fluid glucose levels to future interstitial fluid glucose levels. Using this model, we derived an improved model for calculating blood glucose levels. In the experiments conducted, this model outperformed the Steil-Rebrin model while introducing no additional requirements for glucose sample collection. In subcutaneous tissue, 26.71% of the calculated blood glucose levels had absolute values of relative differences from smoothed measured blood glucose levels less than or equal to 5% using the Steil-Rebrin model. However, the same difference interval was encountered in 63.01% of the calculated blood glucose levels using the proposed model. In addition, 79.45% of the levels calculated with the Steil-Rebrin model compared with 95.21% of the levels calculated with the proposed model had 20% difference intervals. Copyright © 2014 Elsevier Ltd. All rights reserved.

  6. Translational research in pediatrics III: bronchoalveolar lavage.

    PubMed

    Radhakrishnan, Dhenuka; Yamashita, Cory; Gillio-Meina, Carolina; Fraser, Douglas D

    2014-07-01

    The role of flexible bronchoscopy and bronchoalveolar lavage (BAL) for the care of children with airway and pulmonary diseases is well established, with collected BAL fluid most often used clinically for microbiologic pathogen identification and cellular analyses. More recently, powerful analytic research methods have been used to investigate BAL samples to better understand the pathophysiological basis of pediatric respiratory disease. Investigations have focused on the cellular components contained in BAL fluid, such as macrophages, lymphocytes, neutrophils, eosinophils, and mast cells, as well as the noncellular components such as serum molecules, inflammatory proteins, and surfactant. Molecular techniques are frequently used to investigate BAL fluid for the presence of infectious pathologies and for cellular gene expression. Recent advances in proteomics allow identification of multiple protein expression patterns linked to specific respiratory diseases, whereas newer analytic techniques allow for investigations on surfactant quantification and function. These translational research studies on BAL fluid have aided our understanding of pulmonary inflammation and the injury/repair responses in children. We review the ethics and practices for the execution of BAL in children for translational research purposes, with an emphasis on the optimal handling and processing of BAL samples. Copyright © 2014 by the American Academy of Pediatrics.

  7. Rapid Assessment of Salivary MMP-8 and Periodontal Disease Using Lateral Flow Immunoassay

    PubMed Central

    Johnson, N.; Ebersole, J.L.; Kryscio, R.J.; Danaher, R. J.; Dawson, D.; Al-Sabbagh, M.; Miller, C.S.

    2016-01-01

    Objective This study determined the efficacy of a novel point-of-care immunoflow device (POCID) for detecting matrix metalloproteinase (MMP)-8 concentrations in oral fluids in comparison with a gold-standard laboratory-based immunoassay. Methods Oral rinse fluid and whole expectorated saliva samples were collected from 41 participants clinically classified as periodontally healthy or diseased. Samples were analyzed for MMP-8 by Luminex immunoassay and POCID. Photographed POCID results were assessed by optical scan and visually by two examiners. Data were analyzed by Pearson correlation and receiver operator characteristics. Results MMP-8 was readily detected by the POCID, and concentrations correlated well with Luminex for both saliva and rinse fluids (r=0.57–0.93). Thresholds that distinguished periodontitis from health were delineated from both the optical scans and visual reads of the POCID (sensitivity 0.7–0.9, specificity 0.5–0.7; p < 0.05). Conclusions Performance of this POCID for detecting MMP-8 in oral rinse fluid or saliva was excellent. These findings help demonstrate the utility of salivary biomarkers for distinguishing periodontal disease from health using a rapid point-of-care approach. PMID:27273425

  8. Ultra-high performance supercritical fluid chromatography of lignin-derived phenols from alkaline cupric oxide oxidation.

    PubMed

    Sun, Mingzhe; Lidén, Gunnar; Sandahl, Margareta; Turner, Charlotta

    2016-08-01

    Traditional chromatographic methods for the analysis of lignin-derived phenolic compounds in environmental samples are generally time consuming. In this work, an ultra-high performance supercritical fluid chromatography method with a diode array detector for the analysis of major lignin-derived phenolic compounds produced by alkaline cupric oxide oxidation was developed. In an analysis of a collection of 11 representative monomeric lignin phenolic compounds, all compounds were clearly separated within 6 min with excellent peak shapes, with a limit of detection of 0.5-2.5 μM, a limit of quantification of 2.5-5.0 μM, and a dynamic range of 5.0-2.0 mM (R(2) > 0.997). The new ultra-high performance supercritical fluid chromatography method was also applied for the qualitative and quantitative analysis of lignin-derived phenolic compounds obtained upon alkaline cupric oxide oxidation of a commercial humic acid. Ten out of the previous eleven model compounds could be quantified in the oxidized humic acid sample. The high separation power and short analysis time obtained demonstrate for the first time that supercritical fluid chromatography is a fast and reliable technique for the analysis of lignin-derived phenols in complex environmental samples. © 2016 The Authors, Journal of Separation Science Published by WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. CT and MRI assessment of symptomatic organized pancreatic fluid collections and pancreatic duct disruption: an interreader variability study using the revised Atlanta classification 2012.

    PubMed

    Kamal, Ayesha; Singh, Vikesh K; Akshintala, Venkata S; Kawamoto, Satomi; Tsai, Salina; Haider, Maera; Fishman, Elliot K; Kamel, Ihab R; Zaheer, Atif

    2015-08-01

    Compare CT and MRI for fluid/debris component estimate and pancreatic duct (PD) communication with organized pancreatic fluid collections in acute pancreatitis. Evaluate fat density globules on CT as marker for debris. 29 Patients with 46 collections with CECT and MRI performed ≥4 weeks of symptom onset assessed for necrotizing pancreatitis, estimated percentage of fluid volume and PD involvement by two radiologists on separate occasions. T2WI used as standard for estimated percentage of fluid volume. Presence of fat globules and fluid attenuation on CT was recorded. Spearman rank correlation and kappa statistics were used to assess the correlation between imaging techniques and interreader agreement, respectively. Necrotizing pancreatitis seen on CT in 27 (93%, κ 0.119) vs. 20 (69%, κ 0.748) patients on MRI. CT identified 42 WON and 4 pseudocysts vs. 34 WON, and 12 pseudocysts on MRI. Higher interreader agreement for percentage fluid volume on MRI (κ = 0.55) vs. CT (κ = 0.196). Accuracy of CT in evaluation of percentage fluid volume was 65% using T2WI MRI used as standard. Fat globules identified on CT in 13(65%) out of 20 collections containing <75% fluid vs. 4(15%) out of 26 collections containing >75% fluid (p = 0.0001). PD involvement confidently excluded on CT in 68% collections vs. 93% on MRI. MRI demonstrates higher reproducibility for fluid to debris component estimation. Fat globules on CT were frequently seen in organized pancreatic fluid collections with large amount of debris. PD disruption more confidently excluded on MRI. This information may be helpful for pre-procedure planning.

  10. Data Stewardship in the Ocean Sciences Needs to Include Physical Samples

    NASA Astrophysics Data System (ADS)

    Carter, M.; Lehnert, K.

    2016-02-01

    Across the Ocean Sciences, research involves the collection and study of samples collected above, at, and below the seafloor, including but not limited to rocks, sediments, fluids, gases, and living organisms. Many domains in the Earth Sciences have recently expressed the need for better discovery, access, and sharing of scientific samples and collections (EarthCube End-User Domain workshops, 2012 and 2013, http://earthcube.org/info/about/end-user-workshops), as has the US government (OSTP Memo, March 2014). iSamples (Internet of Samples in the Earth Sciences) is a Research Coordination Network within the EarthCube program that aims to advance the use of innovative cyberinfrastructure to support and advance the utility of physical samples and sample collections for science and ensure reproducibility of sample-based data and research results. iSamples strives to build, grow, and foster a new community of practice, in which domain scientists, curators of sample repositories and collections, computer and information scientists, software developers and technology innovators engage in and collaborate on defining, articulating, and addressing the needs and challenges of physical samples as a critical component of digital data infrastructure. A primary goal of iSamples is to deliver a community-endorsed set of best practices and standards for the registration, description, identification, and citation of physical specimens and define an actionable plan for implementation. iSamples conducted a broad community survey about sample sharing and has created 5 different working groups to address the different challenges of developing the internet of samples - from metadata schemas and unique identifiers to an architecture for a shared cyberinfrastructure to manage collections, to digitization of existing collections, to education, and ultimately to establishing the physical infrastructure that will ensure preservation and access of the physical samples. Repositories that curate marine sediment cores and dredge samples from the oceanic crust are participating in iSamples, but many other samples collected in the Ocean sciences are not yet represented. This presentation aims to engage a wider spectrum of Ocean scientists and sample curators in iSamples.

  11. Determination of glycols in air: development of sampling and analytical methodology and application to theatrical smokes.

    PubMed

    Pendergrass, S M

    1999-01-01

    Glycol-based fluids are used in the production of theatrical smokes in theaters, concerts, and other stage productions. The fluids are heated and dispersed in aerosol form to create the effect of a smoke, mist, or fog. There have been reports of adverse health effects such as respiratory irritation, chest tightness, shortness of breath, asthma, and skin rashes. Previous attempts to collect and quantify the aerosolized glycols used in fogging agents have been plagued by inconsistent results, both in the efficiency of collection and in the chromatographic analysis of the glycol components. The development of improved sampling and analytical methodology for aerosolized glycols was required to assess workplace exposures more effectively. An Occupational Safety and Health Administration versatile sampler tube was selected for the collection of ethylene glycol, propylene glycol, 1,3-butylene glycol, diethylene glycol, triethylene glycol, and tetraethylene glycol aerosols. Analytical methodology for the separation, identification, and quantitation of the six glycols using gas chromatography/flame ionization detection is described. Limits of detection of the glycol analytes ranged from 7 to 16 micrograms/sample. Desorption efficiencies for all glycol compounds were determined over the range of study and averaged greater than 90%. Storage stability results were acceptable after 28 days for all analytes except ethylene glycol, which was stable at ambient temperature for 14 days. Based on the results of this study, the new glycol method was published in the NIOSH Manual of Analytical Methods.

  12. Gas and porewater composition of shallow sediments in the Tuaheni Basin, New Zealand

    NASA Astrophysics Data System (ADS)

    Rose, P. S.; Coffin, R. B.; Yoza, B.; Boyd, T. J.; Crutchley, G. J.; Mountjoy, J. J.; Pecher, I. A.

    2015-12-01

    Seismic profiles collected during previous investigations on the Hikurangi Margin, off the North Island, New Zealand showed bottom simulating reflectors (BSRs), which are generally indicative of the presence of free gas. Further, double BSRs clearly identified in the Tuaheni Basin were hypothesized to result from differences in gas composition and fluid migration. During a cruise on the RV Tangaroa in June 2015 (TAN 1508) additional seismic data were collected and used to identify piston coring targets. Coring locations were selected to sample around BSR pinch-outs and possible fluid migration pathways to determine gas composition and flux. Shallow sediments collected in June 2015 in the Tuaheni Basin had relatively low sediment headspace CH4 concentrations (6000ppm. Higher molecular weight alkanes were not detected in the sediment headspace gas at any location. Sediment porewater sulfate, chloride and sulfide concentrations will be presented with CH4concentration profiles and geophysical data.

  13. Simultaneous measurement of monoamine metabolites and 5-methyltetrahydrofolate in the cerebrospinal fluid of children.

    PubMed

    Akiyama, Tomoyuki; Hayashi, Yumiko; Hanaoka, Yoshiyuki; Shibata, Takashi; Akiyama, Mari; Nakamura, Kazuyuki; Tsuyusaki, Yu; Kubota, Masaya; Yoshinaga, Harumi; Kobayashi, Katsuhiro

    2017-02-01

    We describe a new method for simultaneous measurement of monoamine metabolites (3-O-methyldopa [3-OMD], 3-methoxy-4-hydroxyphenylethyleneglycol [MHPG], 5-hydroxyindoleacetic acid [5-HIAA], and homovanillic acid [HVA]) and 5-methyltetrahydrofolate (5-MTHF) and its use on cerebrospinal fluid (CSF) samples from pediatric patients. Monoamine metabolites and 5-MTHF were measured by high-performance liquid chromatography with fluorescence detection. CSF samples were prospectively collected from children according to a standardized collection protocol in which the first 1-ml fraction was used for analysis. Monoamine metabolites and 5-MTHF were separated within 10min. They showed linearity from the limit of detection to 1024nmol/l. The limit of quantification of each metabolite was sufficiently low for the CSF sample assay. In 42 CSF samples after excluding cases with possibly altered neurotransmitter profiles, the concentrations of 3-OMD, MHPG, 5-HIAA, HVA, and 5-MTHF showed significant age dependence and their ranges were comparable with the reference values in the literature. The metabolite profiles of aromatic l-amino acid decarboxylase deficiency, Segawa disease, and folate receptor α defect by this method were compatible with those in the literature. This method is a simple means of measuring CSF monoamine metabolites and 5-MTHF, and is especially useful for laboratories not equipped with electrochemical detectors. Copyright © 2016 Elsevier B.V. All rights reserved.

  14. Hydrologic data for aquifers in Philadelphia, Pennsylvania

    USGS Publications Warehouse

    Paulachok, G.N.; Wood, C.R.; Norton, L.J.

    1984-01-01

    Selected data on the ground-water resources of Philadelphia, Pennsylvania, are presented in this report. Information including water levels and data on aquifers is tabulated for 828 wells and 3 sumps. Chemical analyses are given for 1,467 water samples obtained from 205 sites and include 103 analyses for trace elements and 68 analyses for volatile organic compounds. An index of geophysical logs including gamma ray, neutron, caliper, fluid conductivity, fluid velocity, single-point resistance, spontaneous potential, and temperature determinations made in 51 wells is also presented. Data-collection sites are shown on a 1:50,000 scale location map.

  15. BAT3 Analyzer: Real-Time Data Display and Interpretation Software for the Multifunction Bedrock-Aquifer Transportable Testing Tool (BAT3)

    USGS Publications Warehouse

    Winston, Richard B.; Shapiro, Allen M.

    2007-01-01

    The BAT3 Analyzer provides real-time display and interpretation of fluid pressure responses and flow rates measured during geochemical sampling, hydraulic testing, or tracer testing conducted with the Multifunction Bedrock-Aquifer Transportable Testing Tool (BAT3) (Shapiro, 2007). Real-time display of the data collected with the Multifunction BAT3 allows the user to ensure that the downhole apparatus is operating properly, and that test procedures can be modified to correct for unanticipated hydraulic responses during testing. The BAT3 Analyzer can apply calibrations to the pressure transducer and flow meter data to display physically meaningful values. Plots of the time-varying data can be formatted for a specified time interval, and either saved to files, or printed. Libraries of calibrations for the pressure transducers and flow meters can be created, updated and reloaded to facilitate the rapid set up of the software to display data collected during testing with the Multifunction BAT3. The BAT3 Analyzer also has the functionality to estimate calibrations for pressure transducers and flow meters using data collected with the Multifunction BAT3 in conjunction with corroborating check measurements. During testing with the Multifunction BAT3, and also after testing has been completed, hydraulic properties of the test interval can be estimated by comparing fluid pressure responses with model results; a variety of hydrogeologic conceptual models of the formation are available for interpreting fluid-withdrawal, fluid-injection, and slug tests.

  16. Sterile Fluid Collections in Acute Pancreatitis: Catheter Drainage Versus Simple Aspiration

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Walser, Eric M.; Nealon, William H.; Marroquin, Santiago

    2006-02-15

    Purpose. To compare the clinical outcome of needle aspiration versus percutaneous catheter drainage of sterile fluid collections in patients with acute pancreatitis. Methods. We reviewed the clinical and imaging data of patients with acute pancreatic fluid collections from 1998 to 2003. Referral for fluid sampling was based on elevated white blood cell count and fevers. Those patients with culture-negative drainages or needle aspirations were included in the study. Fifteen patients had aspiration of 10-20 ml fluid only (group A) and 22 patients had catheter placement for chronic evacuation of fluid (group C). We excluded patients with grossly purulent collections andmore » chronic pseudocysts. We also recorded the number of sinograms and catheter changes and duration of catheter drainage. The CT severity index, Ranson scores, and maximum diameter of abdominal fluid collections were calculated for all patients at presentation. The total length of hospital stay (LOS), length of hospital stay after the drainage or aspiration procedure (LOS-P), and conversions to percutaneous and/or surgical drainage were recorded as well as survival. Results. The CT severity index and acute Ransom scores were not different between the two groups (p = 0.15 and p = 0.6, respectively). When 3 crossover patients from group A to group C were accounted for, the duration of hospitalization did not differ significantly, with a mean LOS and LOS-P of 33.8 days and 27.9 days in group A and 41.5 days and 27.6 days in group C, respectively (p = 0.57 and 0.98, respectively). The 60-day mortality was 2 of 15 (13%) in group A and 2 of 22 (9.1%) in group C. Kaplan-Meier survival curves for the two groups were not significantly different (p 0.3). Surgical or percutaneous conversions occurred significantly more often in group A (7/15, 47%) than surgical conversions in group C (4/22, 18%) (p 0.03). Patients undergoing catheter drainage required an average of 2.2 sinograms/tube changes and kept catheters in for an average of 52 days. Aspirates turned culture-positive in 13 of 22 patients (59%) who had chronic catheterization. In group A, 3 of the 7 patients converted to percutaneous or surgical drainage had infected fluid at the time of conversion (total positive culture rate in group A 3/15 or 20%). Conclusions. There is no apparent clinical benefit for catheter drainage of sterile fluid collections arising in acute pancreatitis as the length of hospital stay and mortality were similar between patients undergoing aspiration versus catheter drainage. However, almost half of patients treated with simple aspiration will require surgical or percutaneous drainage at some point. Disadvantages of chronic catheter drainage include a greater than 50% rate of bacterial colonization and the need for multiple sinograms and tube changes over an average duration of about 2 months.« less

  17. Reduction of hexavalent chromium by fasted and fed human gastric fluid. I. Chemical reduction and mitigation of mutagenicity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    De Flora, Silvio, E-mail: sdf@unige.it

    Evaluation of the reducing capacity of human gastric fluid from healthy individuals, under fasted and fed conditions, is critical for assessing the cancer hazard posed by ingested hexavalent chromium [Cr(VI)] and for developing quantitative physiologically-based pharmacokinetic models used in risk assessment. In the present study, the patterns of Cr(VI) reduction were evaluated in 16 paired pre- and post-meal gastric fluid samples collected from 8 healthy volunteers. Human gastric fluid was effective both in reducing Cr(VI), as measured by using the s-diphenylcarbazide colorimetric method, and in attenuating mutagenicity in the Ames test. The mean (± SE) Cr(VI)-reducing ability of post-meal samplesmore » (20.4 ± 2.6 μg Cr(VI)/mL gastric fluid) was significantly higher than that of pre-meal samples (10.2 ± 2.3 μg Cr(VI)/mL gastric fluid). When using the mutagenicity assay, the decrease of mutagenicity produced by pre-meal and post-meal samples corresponded to reduction of 13.3 ± 1.9 and 25.6 ± 2.8 μg Cr(VI)/mL gastric fluid, respectively. These data are comparable to parallel results conducted by using speciated isotope dilution mass spectrometry. Cr(VI) reduction was rapid, with > 70% of total reduction occurring within 1 min and 98% of reduction is achieved within 30 min with post-meal gastric fluid at pH 2.0. pH dependence was observed with decreasing Cr(VI) reducing capacity at higher pH. Attenuation of the mutagenic response is consistent with the lack of DNA damage observed in the gastrointestinal tract of rodents following administration of ≤ 180 ppm Cr(VI) for up to 90 days in drinking water. Quantifying Cr(VI) reduction kinetics in the human gastrointestinal tract is necessary for assessing the potential hazards posed by Cr(VI) in drinking water. - Highlights: • Cr(VI) reduction capacity was greater in post-meal than paired pre-meal samples. • Cr(VI) reduction was rapid, pH dependent, and due to heat stable components. • Gastric fluid attenuates the mutagenicity of Cr(VI) and reduces risk of GI cancer. • The results are useful to quantitatively evaluate the fate of ingested Cr(VI).« less

  18. Primary Total Knee Replacement: Is Suction a Portal of Infection?

    PubMed Central

    Budnar, Vijaya M; Amirfeyz, Rouin; Ng, Michael; Bannister, Gordon C; Blom, Ashley W

    2009-01-01

    INTRODUCTION Pulsed lavage during a total knee replacement usually leaves a pool of fluid on the surgical drapes. It is common practice to suck away this fluid using the same suction device used intra-operatively. This could be a cause of direct wound contamination. We hypothesised that bacteria contaminate fluid that collects around the foot in total knee replacement surgery and that suction equipment could be a portal of contamination. We also hypothesised that bacterial count in the fluid is lower if chlorhexidine, rather than saline, is used in the pulsed lavage. PATIENTS AND METHODS Forty patients undergoing primary total knee replacement were divided into two groups. The first group had pulsed lavage with normal saline and the second with 0.05% chlorhexidine. RESULTS At the end of the operation, 20 ml of fluid, pooled on the surgical drapes was aspirated and cultured for bacterial growth. None of the fluid samples showed bacterial growth. CONCLUSIONS Suction device used peri-operatively during knee replacement is unlikely to be a cause of wound contamination. Pulsed lavage with normal saline is as effective as lavage with chlorhexidine. PMID:19335972

  19. Flehmen response in bull: role of vaginal mucus and other body fluids of bovine with special reference to estrus.

    PubMed

    Sankar, R; Archunan, G

    2004-07-30

    The present investigation was carried out with a view to evaluate the frequency of Flehmen behaviour in bull in response to body fluids of cows in various stages of the estrous cycle, in the context of estrus detection. The study was performed on free moving bulls under natural conditions. Samples of vaginal mucus, saliva, faeces and milk of pro-estrus, estrus and di-estrus stages collected from donor cows were rubbed individually onto the genital regions of non-estrus animals (dummy cows) and the bulls were observed for 30 min for assessment of Flehmen behaviour. The duration of Flehmen behaviour shown by bulls was maximum towards the dummy cows receiving estrus sample. Such Flehmen behaviour, however, did not occur in bulls in response to the cows receiving samples of other stages. The statistical significance was higher (P < 0.001) in exhibiting repeated Flehmen behaviour towards estrus as compared to those of pro-estrus and di-estrus. Among the various body fluids tested, the exhibition of Flehmen behaviour was significantly higher (P < 0.01) in response to estrus vaginal fluid. No response was observed on dummy cows (control) to which only water was applied on the genital region. The results suggest that vaginal mucus may act as an additional/secondary source along with urine in eliciting copulatary behaviour and executing coitus in bulls during estrus. The results further suggest that in addition to vaginal mucus, other body fluids like saliva, faeces and milk have estrus-related odours and are probably involved in bovine bio-communication.

  20. Multiple viral genome search in endolabyrinthic fluids of profoundly deaf patients: possible cytomegalovirus intracochlear reactivation.

    PubMed

    Di Nardo, W; Cattani, P; Lopizzo, T; Cantore, I; Marchese, M R; Marchetti, S; Scorpecci, A; Giannantonio, S; Parrilla, C; Cianfrone, F; Fadda, G; Paludetti, G

    2009-01-01

    The cause of about 30% of bilateral sensorineural hearing loss (SNHL) is still unknown. A viral etiology is among the most frequently proposed ones and the supposed diagnosis is only based upon few clinical and laboratory data. The detection of viral presence within a damaged compartment may represent a way to supply interesting data for confirmation of viral etiology and to explain pathogenic mechanisms. The aim of our study was to identify the possible presence of pathogenic viruses in the inner ear extracellular compartment in patients with bilateral severe sensorineural deafness of unknown etiology who underwent cochlear implant surgery. 4 patients, aged from 2 to 7 years and affected by SNHL underwent cochlear implantation surgery and, at the same time, endolabyrinthine fluid sampling. The samples were subsequently sent for viral nucleic acid extraction and polymerase chain reaction (PCR) treatment: multiplex PCR and realtime-PCR were used. In each endolabyrinthine fluid sample, cytomegalovirus (CMV), Epstein-Barr virus (EBV), varicella-zoster virus (VZV), herpes simplex virus type 1 and 2 (HSV-1, HSV-2) and enterovirus genomes were searched for. One patient was positive for intracochlear CMV, as confirmed by another base-pair segment PCR. EBV, VZV, HSV and enterovirus were detected in none of the 4 patients. Our finding of CMV genome within the cochlea of a deaf patient without any evidence of acute and prenatal CMV infection suggests its possible role in postnatal inner ear injury through reactivation of latent virus within the cochlea. This hypothesis could also be considered valid for some patients with anti-CMV-IgG-positive serology and absence of endolabyrinthine viral genome since viruses can be in an inactive state at the time of fluid collection. PCR has proved to be a very useful tool in order to investigate infectious causes of deafness even for more than one virus type at a time and in a limited quantity of sample, such as the small volume of endolabyrinthine liquid collected from children during cochlear implant surgery. Copyright (C) 2009 S. Karger AG, Basel.

  1. Limited fluid in carbonate-shale hosted thrust faults of the Rocky Mountain Fold-and-Thrust Belt (Sun River Canyon, Montana)

    NASA Astrophysics Data System (ADS)

    OBrien, V. J.; Kirschner, D. L.

    2001-12-01

    It is widely accepted that fluids play a fundamental role in the movement of thrust faults in foreland fold-and-thrust belts. We have begun a combined structure-geochemistry study of faults in the Rocky Mountain fold-and-thrust belt in order to provide more insight into the occurrence and role(s) of fluid in the deformation of thrust faults. We focus on faults exposed in the Sun River Canyon of Montana, an area that contains some of the best exposures of the Rocky Mountain fold-and-thrust belt in the U.S. Samples were collected from two well exposed thrusts in the Canyon -- the Diversion and French thrusts. Both faults have thrust Mississippian dolostones over Cretaceous shales. Displacement exceeds several kilometers. Numerous small-displacement, subsidiary faults characterize the deformation in the hanging wall carbonates. The footwall shales accommodated more penetrative deformation, resulting in well developed foliation and small-scale folds. Stable isotope data have been obtained from host rock samples and veins from these faults. The data delimit an arcuate trend in oxygen-carbon isotope space. Approximately 50 host rock carbonate samples from the hanging walls have carbon and oxygen isotope values ranging from +3 to 0 and 28 to 19 per mil, respectively. There is no apparent correlation between isotopic values and distance from thrust fault at either locality. Fifteen samples of fibrous slickensides on small-displacement faults in the hanging walls have similar carbon and lower oxygen isotope values (down to 16 per mil). And 15 veins that either post-date thrusting or are of indeterminate origin have carbon and oxygen isotope values down to -3 and12 per mil, respectively. The isotopic data collected during the initial stages of this project are similar to some results obtained several hundred kilometers north in the Front Ranges of the Canadian Rockies (Kirschner and Kennedy, JGR 2000) and in carbonate fold-thrust belts of the Swiss Helvetic Alps and Italian Apennines. These data are consistent with limited infiltration of fluid through fractures and minor faults into hanging walls of large-displacement thrust faults.

  2. Microbial diversity within basement fluids of the sediment-buried Juan de Fuca Ridge flank

    PubMed Central

    Jungbluth, Sean P; Grote, Jana; Lin, Huei-Ting; Cowen, James P; Rappé, Michael S

    2013-01-01

    Despite its immense size, logistical and methodological constraints have largely limited microbiological investigations of the subseafloor basement biosphere. In this study, a unique sampling system was used to collect fluids from the subseafloor basaltic crust via a Circulation Obviation Retrofit Kit (CORK) observatory at Integrated Ocean Drilling Program borehole 1301A, located at a depth of 2667 m in the Pacific Ocean on the eastern flank of the Juan de Fuca Ridge. Here, a fluid delivery line directly accesses a 3.5 million years old basalt-hosted basement aquifer, overlaid by 262 m of sediment, which serves as a barrier to direct exchange with bottom seawater. At an average of 1.2 × 104 cells ml−1, microorganisms in borehole fluids were nearly an order of magnitude less abundant than in surrounding bottom seawater. Ribosomal RNA genes were characterized from basement fluids, providing the first snapshots of microbial community structure using a high-integrity fluid delivery line. Interestingly, microbial communities retrieved from different CORKs (1026B and 1301A) nearly a decade apart shared major community members, consistent with hydrogeological connectivity. However, over three sampling years, the dominant gene clone lineage changed from relatives of Candidatus Desulforudis audaxviator within the bacterial phylum Firmicutes in 2008 to the Miscellaneous Crenarchaeotic Group in 2009 and a lineage within the JTB35 group of Gammaproteobacteria in 2010, and statistically significant variation in microbial community structure was observed. The enumeration of different phylogenetic groups of cells within borehole 1301A fluids supported our observation that the deep subsurface microbial community was temporally dynamic. PMID:22791235

  3. Rapid activation of the interferon system in vivo.

    PubMed Central

    Dianzani, F; Gullino, P; Baron, S

    1978-01-01

    Experiments were carried out to study the kinetics of local interferon production in the subcutaneous tissues of rats stimulated with Newcastle disease virus. Specifically, the interferon produced and released in the extracellular fluids was collected at various intervals of time in micropore chambers implanted into the subcutaneous tissue of rats. Interferon was detected at moderate titers 1 h after induction, and it was present at high titer at 2 h. The interferon levels remained remarkably high in the samples collected after 3, 5, and 24 h, and in some rats it was still detectable after 48 and 72 h. Since control experiments showed that it requires 2 to 3 h for interferon to penetrate the chambers, it may be concluded that high concentrations of interferon are present in the extracellular fluid within 1 h of induction. The evaluation of the kinetics of production and of the concentrations attained in the extracellular fluid suggests that in a solid tissue a cell infected by a potent interferon inducer may produce interferon early enough and in sufficient quantity to protect neighboring cells before the production of progeny virions. PMID:669799

  4. Nocardia veterana Isolated from Ascitic Fluid of a Patient with Human Immunodeficiency Virus Infection

    PubMed Central

    Godreuil, Sylvain; Didelot, Marie-Noëlle; Perez, Colette; Leflèche, Anne; Boiron, Patrick; Reynes, Jacques; Laurent, Frédéric; Jean-Pierre, Hélène; Marchandin, Hélène

    2003-01-01

    Nocardia veterana is a recently characterized species within the genus Nocardia, and only three human clinical isolates have been reported for this species. We describe a case of ascitic fluid infection in an immunocompromised patient due to N. veterana. To our knowledge, this is the first report of a Nocardia sp. strain from ascitic fluid and the fourth report of N. veterana isolated from human samples. Chemotaxonomic methods showed the strain to belong to the genus Nocardia, and identification to the species level was done by 16S ribosomal DNA gene sequencing. The antibiotic susceptibility profile of N. veterana is reported here for the second time. The strain was deposited in the Collection of the Pasteur Institute and in the Culture Collection of the University of Göteborg (CIP 107497 and CCUG 46576). The corresponding 16S ribosomal DNA gene sequence is available from the GenBank database under accession number AY149599. A phylogenetic analysis was conducted and showed that N. veterana was most closely related to the recently characterized species Nocardia africana rather than to Nocardia vaccinii, as previously reported. PMID:12791927

  5. Characterization of the microbiome of nipple aspirate fluid of breast cancer survivors

    PubMed Central

    Chan, Alfred A.; Bashir, Mina; Rivas, Magali N.; Duvall, Karen; Sieling, Peter A.; Pieber, Thomas R.; Vaishampayan, Parag A.; Love, Susan M.; Lee, Delphine J.

    2016-01-01

    The microbiome impacts human health and disease. Until recently, human breast tissue and milk were presumed to be sterile. Here, we investigated the presence of microbes in the nipple aspirate fluid (NAF) and their potential association with breast cancer. We compared the NAF microbiome between women with a history of breast cancer (BC) and healthy control women (HC) using 16S rRNA gene amplicon sequencing. The NAF microbiome from BC and HC showed significant differences in community composition. Two Operational Taxonomic Units (OTUs) showed differences in relative abundances between NAF collected from BC and HC. In NAF collected from BC, there was relatively higher incidence of the genus Alistipes. By contrast, an unclassified genus from the Sphingomonadaceae family was relatively more abundant in NAF from HC. These findings reflect the ductal source DNA since there were no differences between areolar skin samples collected from BC and HC. Furthermore, the microbes associated with BC share an enzymatic activity, Beta-Glucuronidase, which may promote breast cancer. This is the first report of bacterial DNA in human breast ductal fluid and the differences between NAF from HC and BC. Further investigation of the ductal microbiome and its potential role in breast cancer are warranted. PMID:27324944

  6. Comparison of techniques for culture of dialysis water and fluid.

    PubMed

    Maltais, Jo-Ann B; Meyer, Klemens B; Foster, Meredith C

    2017-04-01

    Microbiological culture of dialysis water and fluid is a routine safety measure. In the United States (U.S.), laboratories perform these cultures on trypticase soy agar at 35-37°C for 48 h (TSA-48h), not on the tryptone glucose extract agar or Reasoner's 2A agar at 17-23°C for 7 days (TGEA-7d and R2A-7d, respectively) recommended by international standards. We compared culture methods to identify samples exceeding the accepted action level of 50 CFU/mL. Dialysis water and fluid samples collected from 41 U.S. dialysis programs between 2011 and 2014 were cultured at two U.S. laboratories. Each sample was cultured using (1) either TGEA-7d or R2A-7d and (2) TSA-48h. We compared proportions exceeding the action level by different methods and test characteristics of TSA-48h to those of TGEA-7d and R2A-7d. The proportion of water samples yielding colony counts ≥50 CFU/mL by TGEA-7d was significantly different from the proportion by TSA-48h (P = 0.001; difference in proportion 4.3% [95%CI 1.3-7.3%]). The proportions of dialysis fluid samples ≥50 CFU/mL by TGEA-7d and TSA-48h were not significantly different; there were no significant differences for comparisons of R2A-7d to TSA-48h. In dialysis fluid, TSA-48h was comparable to TGEA-7d and R2A-7d in identifying samples as having bacterial counts ≥50 CFU/mL. In dialysis water, TSA-48h was comparable to R2A-7d in identifying samples ≥50 CFU/mL, but TGEA-7d did yield significantly more results above 50 CFU/mL. Nonetheless, the negative predictive value of a TSA-48h result of <50 CFU/mL in dialysis water exceeded 95%. © 2016 The Authors Hemodialysis International published by Wiley Periodicals, Inc. on behalf of International Society for Hemodialysis.

  7. Hydrothermal contamination of public supply wells in Napa and Sonoma Valleys, California

    USGS Publications Warehouse

    Forrest, Matthew J.; Kulongoski, Justin T.; Edwards, Matthew S.; Farrar, Christopher D.; Belitz, Kenneth; Norris, Richard D.

    2013-01-01

    Groundwater chemistry and isotope data from 44 public supply wells in the Napa and Sonoma Valleys, California were determined to investigate mixing of relatively shallow groundwater with deeper hydrothermal fluids. Multivariate analyses including Cluster Analyses, Multidimensional Scaling (MDS), Principal Components Analyses (PCA), Analysis of Similarities (ANOSIM), and Similarity Percentage Analyses (SIMPER) were used to elucidate constituent distribution patterns, determine which constituents are significantly associated with these hydrothermal systems, and investigate hydrothermal contamination of local groundwater used for drinking water. Multivariate statistical analyses were essential to this study because traditional methods, such as mixing tests involving single species (e.g. Cl or SiO2) were incapable of quantifying component proportions due to mixing of multiple water types. Based on these analyses, water samples collected from the wells were broadly classified as fresh groundwater, saline waters, hydrothermal fluids, or mixed hydrothermal fluids/meteoric water wells. The Multivariate Mixing and Mass-balance (M3) model was applied in order to determine the proportion of hydrothermal fluids, saline water, and fresh groundwater in each sample. Major ions, isotopes, and physical parameters of the waters were used to characterize the hydrothermal fluids as Na–Cl type, with significant enrichment in the trace elements As, B, F and Li. Five of the wells from this study were classified as hydrothermal, 28 as fresh groundwater, two as saline water, and nine as mixed hydrothermal fluids/meteoric water wells. The M3 mixing-model results indicated that the nine mixed wells contained between 14% and 30% hydrothermal fluids. Further, the chemical analyses show that several of these mixed-water wells have concentrations of As, F and B that exceed drinking-water standards or notification levels due to contamination by hydrothermal fluids.

  8. Chemical Contaminants Found in the Gastrointestinal Tract of Loggerhead Sea Turtles (Caretta caretta)

    NASA Astrophysics Data System (ADS)

    Athey, S. N.; Seaton, P. J.; Mead, R. N.

    2016-02-01

    Plastic is becoming increasingly more abundant in the marine environment. Plastic ingestion has been shown to be a source of exposure to a variety of harmful compounds, such as polycyclic aromatic hydrocarbons (PAHs), bisphenol A (BPA), and phthalates, which are known for their negative physiological effects on the endocrine system as well as their ability to adsorb and leach from plastic into the bodies of marine organisms. The physiological effects of these compounds on loggerhead sea turtles (Caretta caretta) still remain unknown. This study investigated the presence of toxicants on marine plastic samples collected from Bermuda, the Sargasso Sea, and the North Atlantic Ocean. Gas chromatography/triple quadruple mass spectrometry (GC/MS) analysis showed PAHs were present on many plastic debris samples. Plastic additives such as phthalates and (BPA) were also found. ΣPAH concentrations for anthracene, chrysene, benzo[b]fluoranthene, and benzo[k]fluoranthene for 2013 environmental plastic samples averaged 26.7ng/g of plastic. This study also examined the presence of these compounds in fluids from the stomach, small intestine, and large intestine from two adult loggerhead turtles. GC/MS analysis also showed the presence of BPA and phthalates on plastic samples, as well as in two out of the six gastrointestinal fluids samples. Average ΣPAH concentration for GI fluids for the loggerheads in the study was 58.7 ng/mL. This study showed plastic could be a significant source of PAHs in sea turtles and the first to detect PAHs in sea turtle GI fluid. Loggerhead sea turtles are a long living species and could accumulate high concentrations of these endocrine-disrupting chemicals throughout their lifetime.

  9. Perilymph pharmacokinetics of markers and dexamethasone applied and sampled at the lateral semi-circular canal.

    PubMed

    Salt, Alec N; Hartsock, Jared J; Gill, Ruth M; Piu, Fabrice; Plontke, Stefan K

    2012-12-01

    Perilymph pharmacokinetics was investigated by a novel approach, in which solutions containing drug or marker were injected from a pipette sealed into the perilymphatic space of the lateral semi-circular canal (LSCC). The cochlear aqueduct provides the outlet for fluid flow so this procedure allows almost the entire perilymph to be exchanged. After wait times of up to 4 h the injection pipette was removed and multiple, sequential samples of perilymph were collected from the LSCC. Fluid efflux at this site results from cerebrospinal fluid (CSF) entry into the basal turn of scala tympani (ST) so the samples allow drug levels from different locations in the ear to be defined. This method allows the rate of elimination of substances from the inner ear to be determined more reliably than with other delivery methods in which drug may only be applied to part of the ear. Results were compared for the markers trimethylphenylammonium (TMPA) and fluorescein and for the drug dexamethasone (Dex). For each substance, the concentration in fluid samples showed a progressive decrease as the delay time between injection and sampling was increased. This is consistent with the elimination of substance from the ear with time. The decline with time was slowest for fluorescein, was fastest for Dex, with TMPA at an intermediate rate. Simulations of the experiments showed that elimination occurred more rapidly from scala tympani (ST) than from scala vestibuli (SV). Calculated elimination half-times from ST averaged 54.1, 24.5 and 22.5 min for fluorescein, TMPA and Dex respectively and from SV 1730, 229 and 111 min respectively. The elimination of Dex from ST occurred considerably faster than previously appreciated. These pharmacokinetic parameters provide an important foundation for understanding of drug treatments of the inner ear.

  10. Endoscopic Ultrasound-guided drainage of an abdominal fluid collection following Whipple’s resection

    PubMed Central

    Jah, Asif; Jamieson, Neville; Huguet, Emmanuel; Griffiths, William; Carroll, Nicholas; Praseedom, Raaj

    2008-01-01

    Percutaneous aspiration and drainage of post-operative abdominal fluid collections is a well established standard technique. However, some fluid collections are not amenable to percutaneous drainage either due to location or the presence of surrounding visceral structures. Endoscopic Ultrasound (EUS) has been widely used for the drainage of pancreatitis-related abdominal fluid collections. However, there are no reports on the use of this technique in the post-operative setting. We report a case where the EUS-guided technique was used to drain a percutaneously inaccessible post-operative collection which had developed after Whipple’s resection. PMID:19058316

  11. Recovery and Stability of Δ9-Tetrahydrocannabinol Using the Oral-Eze® Oral Fluid Collection System and Intercept® Oral Specimen Collection Device.

    PubMed

    Samano, Kimberly L; Anne, Lakshmi; Johnson, Ted; Tang, Kenneth; Sample, R H Barry

    2015-10-01

    Oral fluid (OF) is increasingly used for clinical, forensic and workplace drug testing as an alternative to urine. Uncertainties surrounding OF collection device performance, drug stability and testing reproducibility may be partially responsible for delays in the implementation of OF testing in regulated drug testing programs. Stability of Δ(9)-tetrahydrocannabinol (THC) fortified and authentic specimens was examined after routine collection, transport and laboratory testing. Acceptable recovery and stability were observed when THC-fortified OF (1.5 and 4.5 ng/mL) was applied to Oral-Eze devices. Neat OF samples collected with Oral-Eze, processed per the package insert, and fortified with THC (3 and 6 ng/mL) were stable (±20%) at room temperature (21-25°C), refrigerated (2-8°C) and frozen (-25 to -15°C) conditions up to 1 month, while samples collected with Intercept devices showed decreases at refrigerated and room temperatures. After long-term refrigerated or frozen storage, maximum reductions in THC concentrations were 42% for Oral-Eze and 69% for Intercept. After ≥1 year frozen storage, 80.7% of laboratory specimens positive for THC (3 ng/mL cut-off) by GC-MS were reconfirmed positive (within 25%), with an average THC decrease of 4.2%. Specimens (n = 47) processed with Oral-Eze (diluted) and tested via enzyme immunoassay were concordant with LC-MS-MS results and showed 100% sensitivity and 95% specificity. Paired specimens collected with Oral-Eze and Intercept exhibited 98% overall agreement between the immunoassay test systems. Collectively, these data demonstrate consistent and reproducible recovery and stability of THC in OF after collection, transport and laboratory testing using the Oral-Eze OF Collection System. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  12. Method of absorbance correction in a spectroscopic heating value sensor

    DOEpatents

    Saveliev, Alexei; Jangale, Vilas Vyankatrao; Zelepouga, Sergeui; Pratapas, John

    2013-09-17

    A method and apparatus for absorbance correction in a spectroscopic heating value sensor in which a reference light intensity measurement is made on a non-absorbing reference fluid, a light intensity measurement is made on a sample fluid, and a measured light absorbance of the sample fluid is determined. A corrective light intensity measurement at a non-absorbing wavelength of the sample fluid is made on the sample fluid from which an absorbance correction factor is determined. The absorbance correction factor is then applied to the measured light absorbance of the sample fluid to arrive at a true or accurate absorbance for the sample fluid.

  13. Pathogen Identification by Multiplex LightMix Real-Time PCR Assay in Patients with Meningitis and Culture-Negative Cerebrospinal Fluid Specimens

    PubMed Central

    Wagner, Karoline; Springer, Burkard; Pires, Valeria P.

    2017-01-01

    ABSTRACT Acute bacterial meningitis is a medical emergency, and delays in initiating effective antimicrobial therapy result in increased morbidity and mortality. Culture-based methods, thus far considered the “gold standard” for identifying bacterial microorganisms, require 24 to 48 h to provide a diagnosis. In addition, antimicrobial therapy is often started prior to clinical sample collection, thereby decreasing the probability of confirming the bacterial pathogen by culture-based methods. To enable a fast and accurate detection of the most important bacterial pathogens causing meningitis, namely, Streptococcus pneumoniae, Haemophilus influenzae, Neisseria meningitidis, Streptococcus agalactiae, and Listeria monocytogenes, we evaluated a commercially available multiplex LightMix real-time PCR (RT-PCR) in 220 cerebrospinal fluid (CSF) specimens. The majority of CSF samples were collected by lumbar puncture, but we also included some CSF samples from patients with symptoms of meningitis from the neurology department that were recovered from shunts. CSF samples were analyzed by multiplex RT-PCR enabling a first diagnosis within a few hours after sample arrival at our institute. In contrast, bacterial identification took between 24 and 48 h by culture. Overall, a high agreement of bacterial identification between culture and multiplex RT-PCR was observed (99%). Moreover, multiplex RT-PCR enabled the detection of pathogens, S. pneumoniae (n = 2), S. agalactiae (n = 1), and N. meningitidis (n = 1), in four culture-negative samples. As a complement to classical bacteriological CSF culture, the LightMix RT-PCR assay proved to be valuable by improving the rapidity and accuracy of the diagnosis of bacterial meningitis. PMID:29237781

  14. Fluid sampling device

    NASA Technical Reports Server (NTRS)

    Studenick, D. K. (Inventor)

    1977-01-01

    An inlet leak is described for sampling gases, more specifically, for selectively sampling multiple fluids. This fluid sampling device includes a support frame. A plurality of fluid inlet devices extend through the support frame and each of the fluid inlet devices include a longitudinal aperture. An opening device that is responsive to a control signal selectively opens the aperture to allow fluid passage. A closing device that is responsive to another control signal selectively closes the aperture for terminating further fluid flow.

  15. Does maternal-fetal transfer of creatine occur in pregnant sheep?

    PubMed

    Baharom, Syed; De Matteo, Robert; Ellery, Stacey; Della Gatta, Paul; Bruce, Clinton R; Kowalski, Greg M; Hale, Nadia; Dickinson, Hayley; Harding, Richard; Walker, David; Snow, Rodney J

    2017-07-01

    Our aim was to determine the disposition of creatine in ovine pregnancy and whether creatine is transferred across the placenta from mother to fetus. Pregnant ewes received either 1 ) a continuous intravenous infusion of creatine monohydrate or saline from 122 to 131 days gestation, with maternal and fetal arterial blood and amniotic fluid samples collected daily for creatine analysis and fetal tissues collected at necropsy at 133 days for analysis of creatine content, or 2 ) a single systemic bolus injection of [ 13 C]creatine monohydrate at 130 days of gestation, with maternal and fetal arterial blood, uterine vein blood, and amniotic fluid samples collected before and for 4 h after injection and analyzed for creatine, creatine isotopic enrichment, and guanidinoacetic acid (GAA; precursor of creatine) concentrations. Presence of the creatine transporter-1 (SLC6A8) and l-arginine:glycine amidinotransferase (AGAT; the enzyme synthesizing GAA) proteins were determined by Western blots of placental cotyledons. The 10-day creatine infusion increased maternal plasma creatine concentration three- to fourfold ( P < 0.05) without significantly changing fetal arterial, amniotic fluid, fetal tissues, or placental creatine content. Maternal arterial 13 C enrichment was increased ( P < 0.05) after bolus [ 13 C]creatine injection without change of fetal arterial 13 C enrichment. SLC6A8 and AGAT proteins were identified in placental cotyledons, and GAA concentration was significantly higher in uterine vein than maternal artery plasma. Despite the presence of SLC6A8 protein in cotyledons, these results suggest that creatine is not transferred from mother to fetus in near-term sheep and that the ovine utero-placental unit releases GAA into the maternal circulation. Copyright © 2017 the American Physiological Society.

  16. Genome sequences of seven foot-and-mouth disease virus isolates collected from serial samples from one persistently infected carrier cow in Vietnam

    USDA-ARS?s Scientific Manuscript database

    Several FMDV carrier cattle were identified in Vietnam by recovery of infectious virus from oropharyngeal fluid. This report contains the first near-complete genome sequences of seven viruses isolated from a single carrier animal over the course of one year. Understanding within-host viral evolution...

  17. Meningitis Associated with Simultaneous Infection by Multiple Dengue Virus Serotypes in Children, Brazil.

    PubMed

    Marinho, Paula Eillanny Silva; Bretas de Oliveira, Danilo; Candiani, Talitah Michel Sanchez; Crispim, Ana Paula Correia; Alvarenga, Pedro Paulo Martins; Castro, Fabrizia Cristina Dos Santos; Abrahão, Jonatas Santos; Rios, Maria; Coimbra, Roney Santos; Kroon, Erna Geessien

    2017-01-01

    To determine the causes of viral meningitis, we analyzed 22 cerebrospinal fluid samples collected during the 2014-2015 dengue epidemics in Brazil. We identified 3 serotypes of dengue virus (DENV-1, -2, and -3), as well as co-infection with 2 or 3 serotypes. We also detected the Asian II genotype of DENV-2.

  18. Comparison of detection of BVDV antigen in various types of tissue and fluid samples collected from persistently infected cattle

    USDA-ARS?s Scientific Manuscript database

    Aim. Bovine viral diarrhea viruses (BVDV) are economically important pathogens of cattle. Most new acute infections of BVDV are acquired from an animal persistently infected (PI) with BVDV. Surveillance programs typically rely on blood or skin biopsies for detection of PI cattle. PI animals have ...

  19. Comparison of Detection of Bovine Virus Diarrhea Virus Antigen in Various Types of Tissue and Fluid Samples Collected from Persistently Infected Cattle

    USDA-ARS?s Scientific Manuscript database

    Bovine viral diarrhea viruses are economically important pathogens of cattle. Most new infections are acquired from animals persistently infected with the virus. Surveillance programs rely on skin biopsies for detection of persistently infected cattle. The purpose of this study was to compare ant...

  20. Beta endorphin in serum and follicular fluid of PCOS- and non-PCOS women.

    PubMed

    Jaschke, Nikolai; Lunger, Fabian; Wildt, Ludwig; Seeber, Beata

    2018-07-01

    To compare the concentrations of beta endorphin in serum and follicular fluid (FF) of PCOS- and non-PCOS women. Secondarily, to investigate associations between beta endorphin and other parameters. Fifty-nine women undergoing in vitro fertilization (IVF) were included in the study. Sixteen were stratified to the PCOS group using the Rotterdam criteria. The remaining 43 women served as controls. Follicular fluid was collected during oocyte retrieval and peripheral blood sampling was performed on the same day. Beta endorphin concentrations in serum and follicular fluid, serum levels of insulin, glucose, LH, estradiol and progesterone were measured. Additionally, testosterone was measured before starting the stimulation protocol. There was no difference in beta endorphin levels between PCOS- and non-PCOS women. The concentration of the peptide was higher in serum than in FF, likely due to collection of FF after ovulation induction and corresponding to the early luteal phase. We found a significant correlation between the number of mature Metaphase II (MII) oocytes retrieved and beta endorphin concentration in FF. In women with biochemical hyperandrogenemia, beta endorphin levels in FF correlated with testosterone levels. Beta Endorphin concentrations in serum and FF do not differ between PCOS- and non PCOS-women undergoing IVF. However, together with sex hormones, beta endorphin might play a key role in oocyte maturation.

  1. An update clinical application of amniotic fluid-derived stem cells (AFSCs) in cancer cell therapy and tissue engineering.

    PubMed

    Gholizadeh-Ghaleh Aziz, Shiva; Fathi, Ezzatollah; Rahmati-Yamchi, Mohammad; Akbarzadeh, Abolfazl; Fardyazar, Zahra; Pashaiasl, Maryam

    2017-06-01

    Recent studies have elucidated that cell-based therapies are promising for cancer treatments. The human amniotic fluid stem (AFS) cells are advantageous cells for such therapeutic schemes that can be innately changed to express therapeutic proteins. HAFSCs display a natural tropism to cancer cells in vivo. They can be useful in cancer cells targeting. Moreover, they are easily available from surplus diagnostic samples during pregnancy and less ethical and legal concern are associated with the collection and application than other putative cells are subjected. This review will designate representatives of amniotic fluid and stem cell derived from amniotic fluid. For this propose, we collect state of human AFS cells data applicable in cancer therapy by dividing this approach into two main classes (nonengineered and engineered based approaches). Our study shows the advantage of AFS cells over other putative cells types in terms differentiation ability to a wide range of cells by potential and effective use in preclinical studies for a variety of diseases. This study has shown the elasticity of human AFS cells and their favorable potential as a multipotent cell source for regenerative stem cell therapy and capable of giving rise to multiple lineages including such as osteoblasts and adipocyte.

  2. The role of interventional radiology in management of benign and malignant gynecologic diseases.

    PubMed

    Yu, Hyeon; Stavas, Joseph M

    2013-10-01

    This article focuses on the role of interventional radiology in the therapeutic and diagnostic management of benign and malignant gynecologic conditions. The subspecialty of interventional radiology utilizes minimally invasive advanced image-guided percutaneous techniques in gynecology that include central venous catheter placement, fluid aspiration, drainage catheter placement, tissue biopsy, inferior vena cava filter placement, and pelvic arterial embolization. Central venous catheters, such as ports, peripherally inserted central catheters, and tunneled catheters, are placed for intermediate to long-term intravenous chemotherapy or total parental nutrition or antibiotics. Patients with refractory malignant ascites or pleural effusion from seeding of advanced gynecologic cancers may benefit by percutaneous aspiration of fluid collections or placement of drainage catheters. Postoperative fluid collections including abscess, seroma, or lymphocele are managed by percutaneous drainage catheter insertion. Pelvic, peritoneal, or retroperitoneal masses can be sampled by image-guided percutaneous biopsy or aspiration of fluid to determine a pathologic diagnosis. Certain patients are at risk for deep venous thrombosis with pulmonary embolism and may benefit from an inferior vena cava filter. Patients with uncontrolled postoperative or postpartum bleeding can be effectively managed with emergent transarterial pelvic embolization. Each of the aforementioned interventions with indications, expected benefits, and complications is described including a published literature.

  3. Value of Routine Dengue Diagnostic Tests in Urine and Saliva Specimens

    PubMed Central

    Andries, Anne-Claire; Duong, Veasna; Ly, Sowath; Cappelle, Julien; Kim, Kim Srorn; Lorn Try, Patrich; Ros, Sopheaktra; Ong, Sivuth; Huy, Rekol; Horwood, Paul; Flamand, Marie; Sakuntabhai, Anavaj; Tarantola, Arnaud; Buchy, Philippe

    2015-01-01

    Background Dengue laboratory diagnosis is essentially based on detection of the virus, its components or antibodies directed against the virus in blood samples. Blood, however, may be difficult to draw in some patients, especially in children, and sampling during outbreak investigations or epidemiological studies may face logistical challenges or limited compliance to invasive procedures from subjects. The aim of this study was to assess the possibility of using saliva and urine samples instead of blood for dengue diagnosis. Methodology/Principal Findings Serial plasma, urine and saliva samples were collected at several time-points between the day of admission to hospital until three months after the onset of fever in children with confirmed dengue disease. Quantitative RT-PCR, NS1 antigen capture and ELISA serology for anti-DENV antibody (IgG, IgM and IgA) detection were performed in parallel on the three body fluids. RT-PCR and NS1 tests demonstrated an overall sensitivity of 85.4%/63.4%, 41.6%/14.5% and 39%/28.3%, in plasma, urine and saliva specimens, respectively. When urine and saliva samples were collected at the same time-points and tested concurrently, the diagnostic sensitivity of RNA and NS1 detection assays was 69.1% and 34.4%, respectively. IgG/IgA detection assays had an overall sensitivity of 54.4%/37.4%, 38.5%/26.8% and 52.9%/28.6% in plasma, urine and saliva specimens, respectively. IgM were detected in 38.1% and 36% of the plasma and saliva samples but never in urine. Conclusions Although the performances of the different diagnostic methods were not as good in saliva and urine as in plasma specimens, the results obtained by qRT-PCR and by anti-DENV antibody ELISA could well justify the use of these two body fluids to detect dengue infection in situations when the collection of blood specimens is not possible. PMID:26406240

  4. Oil mist and vapour concentrations from drilling fluids: inter- and intra-laboratory comparison of chemical analyses.

    PubMed

    Galea, Karen S; Searl, Alison; Sánchez-Jiménez, Araceli; Woldbæk, Torill; Halgard, Kristin; Thorud, Syvert; Steinsvåg, Kjersti; Krüger, Kirsti; Maccalman, Laura; Cherrie, John W; van Tongeren, Martie

    2012-01-01

    There are no recognized analytical methods for measuring oil mist and vapours arising from drilling fluids used in offshore petroleum drilling industry. To inform the future development of improved methods of analysis for oil mist and vapours this study assessed the inter- and intra-laboratory variability in oil mist and vapour analysis. In addition, sample losses during transportation and storage were assessed. Replicate samples for oil mist and vapour were collected using the 37-mm Millipore closed cassette and charcoal tube assembly. Sampling was conducted in a simulated shale shaker room, similar to that found offshore for processing drilling fluids. Samples were analysed at two different laboratories, one in Norway and one in the UK. Oil mist samples were analysed using Fourier transform infrared spectroscopy (FTIR), while oil vapour samples were analysed by gas chromatography (GC). The comparison of replicate samples showed substantial within- and between-laboratory variability in reported oil mist concentrations. The variability in oil vapour results was considerably reduced compared to oil mist, provided that a common method of calibration and quantification was adopted. The study also showed that losses can occur during transportation and storage of samples. There is a need to develop a harmonized method for the quantification of oil mist on filter and oil vapour on charcoal supported by a suitable proficiency testing scheme for laboratories involved in the analysis of occupational hygiene samples for the petroleum industry. The uncertainties in oil mist and vapour measurement have substantial implications in relation to compliance with occupational exposure limits and also in the reliability of any exposure-response information reported in epidemiological studies.

  5. Metabolomics analysis of follicular fluid in women with ovarian endometriosis undergoing in vitro fertilization.

    PubMed

    Karaer, Abdullah; Tuncay, Gorkem; Mumcu, Akın; Dogan, Berat

    2018-05-28

    The purpose of this study was to investigate whether a change in the follicular fluid metabolomics profile due to endometrioma is identifiable. Twelve women with ovarian endometriosis (aged<40 years, with a body mass index [BMI] of <30 kg/m 2 ) and 12 age- and BMI-matched controls (women with infertility purely due to a male factor) underwent ovarian stimulation for intracytoplasmic sperm injection (ICSI). Follicular fluid samples were collected from both of groups at the time of oocyte retrieval for ICSI. Next, nuclear magnetic resonance (NMR) spectroscopy was performed for the collected follicular fluids. The metabolic compositions of the follicular fluids were then compared using univariate and multivariate statistical analyses of NMR data. Univariate and multivariate statistical analyses of NMR data showed that the metabolomic profiles of the follicular fluids obtained from the women with ovarian endometriosis were distinctly different from those obtained from the control group. In comparison with the controls, the follicular fluids of the women with ovarian endometriosis had statistically significant elevated levels of lactate, β-glucose, pyruvate, and valine. We conclude that the levels of lactate, β-glucose, pyruvate, and valine in the follicular fluid of the women with endometrioma were higher than those of the controls. ASRM: American Society for Reproductive Medicine; BMI: body mass index; CPMG: Carr-Purcell-Meiboom-Gill; E 2 : estradiol; ESHRE: European Society of Human Reproduction and Embryology; ERETIC: electronic to access in vivo concentration; FF: follicular fluid; FSH: follicle-stimulating hormone; hCG: human chorionic gonadotropin; HEPES: 2-hydroxyethyl-1-piperazineethanesulfonic acid; ICSI: intracytoplasmic sperm injection; IVF: in vitro fertilization; NMR: nuclear magnetic resonance spectroscopy; PCA: principal component analysis; PCOS: polycystic ovary syndrome; PLS-DA: partial least squares discriminant analysis; ppm: parts per million; PULCON: pulse length-based concentration determination; TSP: 3-(trimethylsilyl)-1-propanesulfonic acid sodium salt; VIP: variable importance in projection.

  6. Volumetric Analysis of Gingival Crevicular Fluid and Peri-Implant Sulcus Fluid in Healthy and Diseased Sites: A Cross-Sectional Split-Mouth Pilot Study

    PubMed Central

    Bevilacqua, Lorenzo; De Biasi, Matteo; Lorenzon, Maria Giulia; Frattini, Costanza; Angerame, Daniele

    2016-01-01

    Background: Researchers have recently drawn attention to the analysis of gingival crevicular fluid (GCF) and peri-implant sulcus fluid (PISF) for the implementation of the diagnosis of periodontal and peri-implant disease. Nevertheless, the measurements of volume and biomarkers concentration can be critically biased when data collected from studies with parallel group design are compared, given the technical difficulties, methodological variables, as well as the variability of crevicular fluid characteristics among different individuals. Objective: The aim of the present study was to assess the GCF and PISF volumes in healthy and diseased sites belonging to the same patient. Method: Ten patients presenting a periodontally healthy tooth, a tooth with periodontitis, an implant with healthy peri-implant tissues and an implant with peri-implantitis were enrolled. Samples of GCF and PISF were collected from each site of interest and their volume measured with a Periotron 8000 device. Non-parametric statistical analysis was performed to test the significance of the differences in GCF and PISF volumes between i) sites of teeth and dental implants with the same condition of health or disease and ii) healthy and diseased sites of both teeth and dental implants subgroups. The correlation between probing pocket depth (PPD) and fluid production was also tested (p<0.05). Results: Healthy periodontal and peri-implant tissues produced comparable amounts of fluid that was significantly lower than in diseased sites (p<0.05). In the presence of diagnosed disease, the volumes of GCF and PISF were similar, too. The correlation between PPD and fluid production was significant only in healthy sites (PPD/GCF, ρ=0.890, p<0.001; PPD/PISF, ρ=0.810; p<0.005). Conclusion: The periodontal and peri-implant tissues behaved similarly in terms of fluid production in condition of both health and active disease. PMID:27335614

  7. Real-time PCR quantification of Vibrio parahaemolyticus in oysters using an alternative matrix.

    PubMed

    Kaufman, G E; Blackstone, G M; Vickery, M C L; Bej, A K; Bowers, J; Bowen, Michael D; Meyer, Richard F; DePaola, A

    2004-11-01

    This study examined the relationship between levels of total Vibrio parahaemolyticus found in oyster tissues and mantle fluid with the goal of using mantle fluid as a template matrix in a new quantitative real-time PCR assay targeting the thermolabile hemolysin (tlh) gene for the enumeration of total V. parahaemolyticus in oysters. Oysters were collected near Mobile Bay, Ala., in June, July, and September and tested immediately after collection and storage at 26 degrees C for 24 h. Initial experiments using DNA colony hybridization targeting tlh demonstrated that natural V. parahaemolyticus levels in the mantle fluid of individual oysters were strongly correlated (r = 0.85, P < 0.05) with the levels found in their tissues. When known quantities of cultured V. parahaemolyticus cells were added to real-time PCR reactions that contained mantle fluid and oyster tissue matrices separately pooled from multiple oysters, a strong linear correlation was observed between the real-time PCR cycle threshold and the log concentration of cells inoculated into each PCR reaction (mantle fluid: r = 0.98, P < 0.05; and oyster: r = 0.99, P < 0.05). However, the mantle fluid exhibited less inhibition of the PCR amplification than the homogenized oyster tissue. Analysis of natural V. parahaemolyticus populations in mantle fluids using both colony hybridization and real-time PCR demonstrated a significant (P < 0.05) but reduced correlation (r = -0.48) between the two methods. Reductions in the efficiency of the real-time PCR that resulted from low population densities of V. parahaemolyticus and PCR inhibitors present in the mantle fluid of some oysters (with significant oyster-to-oyster variation) contributed to the reduction in correlation between the methods that was observed when testing natural V. parahaemolyticus populations. The V. parahaemolyticus-specific real-time PCR assay used for this study could estimate elevated V. parahaemolyticus levels in oyster mantle fluid within 1 h from sampling time.

  8. Pockmarks off Big Sur, California

    USGS Publications Warehouse

    Paull, C.; Ussler, W.; Maher, N.; Greene, H. Gary; Rehder, G.; Lorenson, T.; Lee, H.

    2002-01-01

    A pockmark field was discovered during EM-300 multi-beam bathymetric surveys on the lower continental slope off the Big Sur coast of California. The field contains ??? 1500 pockmarks which are between 130 and 260 m in diameter, and typically are 8-12 m deep located within a 560 km2 area. To investigate the origin of these features, piston cores were collected from both the interior and the flanks of the pockmarks, and remotely operated vehicle observation (ROV) video and sampling transects were conducted which passed through 19 of the pockmarks. The water column within and above the pockmarks was sampled for methane concentration. Piston cores and ROV collected push cores show that the pockmark field is composed of monotonous fine silts and clays and the cores within the pockmarks are indistinguishable from those outside the pockmarks. No evidence for either sediment winnowing or diagenetic alteration suggestive of fluid venting was obtained. 14C measurements of the organic carbon in the sediments indicate continuous sedimentation throughout the time resolution of the radiocarbon technique ( ??? 45000 yr BP), with a sedimentation rate of ??? 10 cm per 1000 yr both within and between the pockmarks. Concentrations of methane, dissolved inorganic carbon, sulfate, chloride, and ammonium in pore water extracted from within the cores are generally similar in composition to seawater and show little change with depth, suggesting low biogeochemical activity. These pore water chemical gradients indicate that neither significant accumulations of gas are likely to exist in the shallow subsurface ( ??? 100 m) nor is active fluid advection occurring within the sampled sediments. Taken together the data indicate that these pockmarks are more than 45000 yr old, are presently inactive, and contain no indications of earlier fluid or gas venting events. ?? 2002 Elsevier Science B.V. All rights reserved.

  9. A dynamic microbial community with high functional redundancy inhabits the cold, oxic subseafloor aquifer

    PubMed Central

    Tully, Benjamin J; Wheat, C Geoff; Glazer, Brain T; Huber, Julie A

    2018-01-01

    The rock-hosted subseafloor crustal aquifer harbors a reservoir of microbial life that may influence global marine biogeochemical cycles. Here we utilized metagenomic libraries of crustal fluid samples from North Pond, located on the flanks of the Mid-Atlantic Ridge, a site with cold, oxic subseafloor fluid circulation within the upper basement to query microbial diversity. Twenty-one samples were collected during a 2-year period to examine potential microbial metabolism and community dynamics. We observed minor changes in the geochemical signatures over the 2 years, yet the microbial community present in the crustal fluids underwent large shifts in the dominant taxonomic groups. An analysis of 195 metagenome-assembled genomes (MAGs) were generated from the data set and revealed a connection between litho- and autotrophic processes, linking carbon fixation to the oxidation of sulfide, sulfur, thiosulfate, hydrogen, and ferrous iron in members of the Proteobacteria, specifically the Alpha-, Gamma- and Zetaproteobacteria, the Epsilonbacteraeota and the Planctomycetes. Despite oxic conditions, analysis of the MAGs indicated that members of the microbial community were poised to exploit hypoxic or anoxic conditions through the use of microaerobic cytochromes, such as cbb3- and bd-type cytochromes, and alternative electron acceptors, like nitrate and sulfate. Temporal and spatial trends from the MAGs revealed a high degree of functional redundancy that did not correlate with the shifting microbial community membership, suggesting functional stability in mediating subseafloor biogeochemical cycles. Collectively, the repeated sampling at multiple sites, together with the successful binning of hundreds of genomes, provides an unprecedented data set for investigation of microbial communities in the cold, oxic crustal aquifer. PMID:29099490

  10. Biomimetic model systems of rigid hair beds: Part II - Experiment

    NASA Astrophysics Data System (ADS)

    Jammalamadaka, Mani S. S.; Hood, Kaitlyn; Hosoi, Anette

    2017-11-01

    Crustaceans - such as lobsters, crabs and stomapods - have hairy appendages that they use to recognize and track odorants in the surrounding fluid. An array of rigid hairs impedes flow at different rates depending on the spacing between hairs and the Reynolds number, Re. At larger Reynolds number (Re>1), fluid travels through the hairs rather than around them, a phenomenon called leakiness. Crustaceans flick their appendages at different speeds in order to manipulate the leakiness between the hairs, allowing the hairs to either detect the odors in a sample of fluid or collect a new sample. Theoretical and numerical studies predict that there is a fast flow region near the hairs that moves closer to the hairs as Re increases. Here, we test this theory experimentally. We 3D printed rigid hairs with an aspect ratio of 30:1 in rectangular arrays with different hair packing fractions. We custom built an experimental setup which establishes poiseuille flow at intermediate Re, Re <=200. We track the flow dynamics through the hair beds using tracer particles and Particle Imaging Velocimetry. We will then compare the modelling predictions with the experimental outcomes.

  11. Detection of oral streptococci in dental unit water lines after therapy with air turbine handpiece: biological fluid retraction more frequent than expected.

    PubMed

    Petti, Stefano; Moroni, Catia; Messano, Giuseppe Alessio; Polimeni, Antonella

    2013-03-01

    Oral streptococci detected in water from dental unit water lines (DUWLs) are a surrogate marker of patients' biological fluid retraction during therapy. We investigated oral streptococci detection rate in DUWLs in a representative sample of private offices in real-life conditions. Samples of nondisinfected water (100 ml) were collected from the DUWL designated for the air turbine handpiece in 81 dental units, immediately after dental treatment of patients with extensive air turbine handpiece use. Water was filtered and plated on a selective medium for oral streptococci and, morphologically, typical colonies of oral streptococci were counted. The lowest detection limit was 0.01 CFU/ml. The oral streptococci detection rate was 72% (95% CI: 62-81%), with a mean level of 0.7 CFU/ml. Oral streptococci detection was not affected by handpiece age or dental treatment type, but was associated with dental unit age. Biological fluid retraction into DUWLs during patient treatment and, possibly, the risk for patient-to-patient blood- or air-borne pathogen transmission are more frequent than expected.

  12. Trimethylamine and trimethylamine oxide levels in normal women and women with bacterial vaginosis reflect a local metabolism in vaginal secretion as compared to urine.

    PubMed

    Wolrath, H; Ståhlbom, B; Hallén, A; Forsum, U

    2005-01-01

    The smell of rotten fish is one of the characteristics of bacterial vaginosis (BV), and is due to trimethylamine (TMA). Trimethylamine can be found in human urine, although most of it occurs as the nonvolatile oxide (TMAO) form. The fraction TMA/TMAO can be expected to be the same in different body fluids if no local production of TMA occurs. In women with BV, TMAO in the vaginal fluid is expected to be chemically reduced by the local bacterial flora to the much more odorous TMA. We have therefore studied the local vaginal production of TMA in vaginal secretion compared to the general TMA-TMAO metabolism that was measured in urine using gas chromatography. Both vaginal fluid and random urine samples were collected from women, with and without BV, attending a Swedish clinic for sexually transmitted diseases, and these samples were analyzed for TMA and TMAO. The results show that a local production of TMA occurs in the vagina that is not part of the general metabolism of TMA-TMAO.

  13. Sampling device for withdrawing a representative sample from single and multi-phase flows

    DOEpatents

    Apley, Walter J.; Cliff, William C.; Creer, James M.

    1984-01-01

    A fluid stream sampling device has been developed for the purpose of obtaining a representative sample from a single or multi-phase fluid flow. This objective is carried out by means of a probe which may be inserted into the fluid stream. Individual samples are withdrawn from the fluid flow by sampling ports with particular spacings, and the sampling parts are coupled to various analytical systems for characterization of the physical, thermal, and chemical properties of the fluid flow as a whole and also individually.

  14. Change in the magnetic properties of bituminous coal intruded by an igneous dike, Dutch Creek Mine, Pitkin County, Colorado

    USGS Publications Warehouse

    Thorpe, A.N.; Senftle, F.E.; Finkelman, R.B.; Dulong, F.T.; Bostick, N.H.

    1998-01-01

    Magnetization measurements have been made on natural coke-coal samples collected at various distances from a felsic porphyry dike in a coal seam in Dutch Creek Mine, Colorado to help characterize the nature and distribution of the iron-bearing phases. The magnetization passes through a maximum at the coke-to-coal transition about 31 cm from the dike contact. The magnetic measurements support the geochemical data indicating that magmatic fluids along with a high-temperature gas pulse moved into the coal bed. Interaction of the magmatic fluids with the coal diminished the reducing power of the thermal gas pulse from the dike to a point about 24 cm into the coal. The hot reducing gas penetrated further and produced a high temperature (~400-525??C) zone (at about 31 cm) just ahead of the magmatic fluids. Metallic iron found in this zone is the principal cause of the observed high magnetization. Beyond this zone, the temperature was too low to alter the coal significantly.Magnetization measurements have been made on natural coke-coal samples collected at various distances from a felsic porphyry dike in a coal seam in Dutch Creek Mine, Colorado to help characterize the nature and distribution of the iron-bearing phases. The magnetization passes through a maximum at the coke-to-coal transition about 31 cm from the dike contact. The magnetic measurements support the geochemical data indicating that magmatic fluids along with a high-temperature gas pulse moved into the coal bed. Interaction of the magmatic fluids with the coal diminished the reducing power of the thermal gas pulse from the dike to a point about 24 cm into the coal. The hot reducing gas penetrated further and produced a high temperature (approximately 400-525 ??C) zone (at about 31 cm) just ahead of the magmatic fluids. Metallic iron found in this zone is the principal cause of the observed high magnetization. Beyond this zone, the temperature was too low to alter the coal significantly.

  15. The calculation of aquifer chemistry in hot-water geothermal systems

    USGS Publications Warehouse

    Truesdell, Alfred H.; Singers, Wendy

    1974-01-01

    The temperature and chemical conditions (pH, gas pressure, and ion activities) in a geothermal aquifer supplying a producing bore can be calculated from the enthalpy of the total fluid (liquid + vapor) produced and chemical analyses of water and steam separated and collected at known pressures. Alternatively, if a single water phase exists in the aquifer, the complete analysis (including gases) of a sample collected from the aquifer by a downhole sampler is sufficient to determine the aquifer chemistry without a measured value of the enthalpy. The assumptions made are that the fluid is produced from a single aquifer and is homogeneous in enthalpy and chemical composition. These calculations of aquifer chemistry involving large amounts of ancillary information and many iterations require computer methods. A computer program in PL-1 to perform these calculations is available from the National Technical Information Service as document PB-219 376.

  16. Pleural fluid smear

    MedlinePlus

    ... the fluid that has collected in the pleural space. This is the space between the lining of the outside of the ... the chest. When fluid collects in the pleural space, the condition is called pleural effusion .

  17. Pleural fluid analysis

    MedlinePlus

    ... of fluid that has collected in the pleural space. This is the space between the lining of the outside of the ... the chest. When fluid collects in the pleural space, the condition is called pleural effusion .

  18. Investigation of the capture of magnetic particles from high-viscosity fluids using permanent magnets

    PubMed Central

    Garraud, A.; Velez, C.; Shah, Y.; Garraud, N.; Kozissnik, B.; Yarmola, E. G.; Allen, K. D.; Dobson, J.; Arnold, D. P.

    2015-01-01

    Goal This paper investigates the practicality of using a small, permanent magnet to capture magnetic particles out of high-viscosity biological fluids, such as synovial fluid. Methods Numerical simulations are used to predict the trajectory of magnetic particles toward the permanent magnet. The simulations are used to determine a “collection volume” with a time-dependent size and shape, which determines the number of particles that can be captured from the fluid in a given amount of time. Results The viscosity of the fluid strongly influences the velocity of the magnetic particles towards the magnet, hence the collection volume after a given time. In regards to the design of the magnet, the overall size is shown to most strongly influence the collection volume in comparison to the magnet shape or aspect ratio. Conclusion Numerical results showed good agreement with in vitro experimental magnetic collection results. Significance In the long-term, this work aims to facilitate optimization of the collection of magnetic particle-biomarker conjugates from high-viscosity biological fluids without the need to remove the fluid from a patient. PMID:26208261

  19. Investigation of the Capture of Magnetic Particles From High-Viscosity Fluids Using Permanent Magnets.

    PubMed

    Garraud, Alexandra; Velez, Camilo; Shah, Yash; Garraud, Nicolas; Kozissnik, Bettina; Yarmola, Elena G; Allen, Kyle D; Dobson, Jon; Arnold, David P

    2016-02-01

    This paper investigates the practicality of using a small, permanent magnet to capture magnetic particles out of high-viscosity biological fluids, such as synovial fluid. Numerical simulations are used to predict the trajectory of magnetic particles toward the permanent magnet. The simulations are used to determine a "collection volume" with a time-dependent size and shape, which determines the number of particles that can be captured from the fluid in a given amount of time. The viscosity of the fluid strongly influences the velocity of the magnetic particles toward the magnet, hence, the collection volume after a given time. In regards to the design of the magnet, the overall size is shown to most strongly influence the collection volume in comparison to the magnet shape or aspect ratio. Numerical results showed good agreement with in vitro experimental magnetic collection results. In the long term, this paper aims to facilitate optimization of the collection of magnetic particle-biomarker conjugates from high-viscosity biological fluids without the need to remove the fluid from a patient.

  20. Cortical gluing and Ringer lactate solution inflation to avoid cortical mantle collapse and subdural fluid collections in pediatric neurosurgery: safety and feasibility.

    PubMed

    Mirone, Giuseppe; Ruggiero, Claudio; Spennato, Pietro; Aliberti, Ferdinando; Trischitta, Vincenzo; Cinalli, Giuseppe

    2015-06-01

    Subdural fluid collections following intraventricular and/or paraventricular procedures in pediatric neurosurgery are common and can be hard to treat. We describe our technique to close cortical defects by the aid of a fibrin adhesive and subsequent Ringer inflation with the aim to avoid cortical mantle collapse and to prevent the development of subdural fluid collections. We report the preliminary results of a prospective study on a consecutive series of 29 children who underwent 37 transcortical or transcallosal surgical procedures since 2008 in our department. In 17 procedures, we performed a transcortical approach on lesions, and in other 19 operations, we operated by a transcallosal. In 5/17 transcortical approaches (29%) and in 3/20 transcallosal approaches (15%), we observed a 5-mm-thick subdural fluid collection of the 5 patients with subdural fluid collections in the transcortical group, 3 patients (17%) underwent surgery for symptomatic or progressive subdural fluid collections. Of the 3 patients in the transcallosal group, a subduro-peritoneal shunt was necessary only for 1 patient (5%). At the very end of the treatment (including chemotherapy and radiotherapy), it was possible to remove the subduro-peritoneal shunt in all these patients because of disappearance of the subdural fluid collections. In pediatric patients after transcortical or transcallosal procedures, the use of a fibrin adhesive to seal surgical opening and subsequent inflation of the residual cavity with Ringer lactate solution to avoid cortical mantle collapse seems safe and appears to prevent the development of subdural fluid collections.

  1. The role of CT-guided percutaneous drainage of loculated air collections: an institutional experience.

    PubMed

    Patel, Bhavik N; Morgan, Madeline; Tyler, Douglas; Paulson, Erik; Jaffe, Tracy A

    2015-10-01

    The purpose of this study is to describe our experience with the role of CT-guided percutaneous drainage of loculated intra-abdominal collections consisting entirely of gas. An IRB-approved retrospective study analyzing patients with air-only intra-abdominal collections over an 8-year period was undertaken. Seven patients referred for percutaneous drainage were included. Size of collections, subsequent development of fluid, and microbiological yield were determined. Clinical outcome was also analyzed. Out of 2835 patients referred for percutaneous drainage between 2004 and 2012, seven patients (5M, 2F; average age 63, range 54-85) met criteria for inclusion with CT showing air-only collections. Percutaneous drain placement (five 8 Fr, one 10 Fr, and one 12 Fr) using Seldinger technique was performed. Four patients (57%) had recently undergone surgery (2 Whipple, 1 colectomy, 1 hepatic resection) while two (29%) had a remote surgery (1 abdominoperineal resection, 1 sigmoidectomy). Despite the lack of detectable fluid on the original CT, 6 patients (86%) had air and fluid aspirated at drainage, 5 (83%) of the aspirates developed positive microbacterial cultures. Four patients (57%) presented with fever at the time of the initial scan, all of whom had positive cultures from aspirated fluid. Four patients (57%) had leukocytosis, all of whom had positive cultures from aspirated fluid. Although relatively rare in occurrence, patients with air-only intra-abdominal collections with signs of infection should be considered for percutaneous management similar to that of conventional infected fluid collections. Although fluid is not visible on CT, these collections can produce fluid that contains organisms.

  2. Benign mural nodules within fluid collections at MRI after soft-tissue sarcoma resection.

    PubMed

    Lantos, Joshua E; Hwang, Sinchun; Panicek, David M

    2014-06-01

    The purpose of this study was to determine the prevalence and clinical significance of nodules within fluid collections on MRI after surgical resection of soft-tissue sarcoma. This retrospective study included 175 patients who underwent resection of primary soft-tissue sarcoma and whose postoperative MRI reports mentioned fluid. Images were reviewed to determine the presence of fluid collections of 1 cm or greater in diameter in the surgical bed and any nodule (measuring ≥ 0.7 cm) within the collection. Signal intensity and characteristics of each collection and rim and presence of septa or blood products were recorded. Size, signal intensity, and contrast enhancement of nodules were reviewed. Nodules were classified as benign or malignant on the basis of histologic results or clinical or MRI follow-up. Fluid collections were present in 75 patients. Of those, 45 collections (60%) showed homogeneous fluid signal intensity and 30 (40%) were heterogeneous; septa were present in 45 (60%) and blood products in 12 (16%). Most collections showed a thin rim (59%) and rim enhancement (88%). Nodules were present along the inner wall of six (8%) collections. Four (66%) nodules enhanced and two (33%) were T1 hyperintense. At follow-up MRI, two nodules were stable in size, one decreased, and three resolved. Nodules in three patients were biopsied; all were benign. Two other patients had no recurrence at follow-up, and another died at 3 months. A nodule within a postoperative fluid collection at MRI after soft-tissue sarcoma resection generally does not represent tumor recurrence; short-interval follow-up MRI is recommended rather than immediate biopsy.

  3. Fluid flow and permeabilities in basement fault zones

    NASA Astrophysics Data System (ADS)

    Hollinsworth, Allan; Koehn, Daniel

    2017-04-01

    Fault zones are important sites for crustal fluid flow, specifically where they cross-cut low permeability host rocks such as granites and gneisses. Fluids migrating through fault zones can cause rheology changes, mineral precipitation and pore space closure, and may alter the physical and chemical properties of the host rock and deformation products. It is therefore essential to consider the evolution of permeability in fault zones at a range of pressure-temperature conditions to understand fluid migration throughout a fault's history, and how fluid-rock interaction modifies permeability and rheological characteristics. Field localities in the Rwenzori Mountains, western Uganda and the Outer Hebrides, north-west Scotland, have been selected for field work and sample collection. Here Archaean-age TTG gneisses have been faulted within the upper 15km of the crust and have experienced fluid ingress. The Rwenzori Mountains are an anomalously uplifted horst-block located in a transfer zone in the western rift of the East African Rift System. The north-western ridge is characterised by a tectonically simple western flank, where the partially mineralised Bwamba Fault has detached from the Congo craton. Mineralisation is associated with hydrothermal fluids heated by a thermal body beneath the Semliki rift, and has resulted in substantial iron oxide precipitation within porous cataclasites. Non-mineralised faults further north contain foliated gouges and show evidence of leaking fluids. These faults serve as an analogue for faults associated with the Lake Albert oil and gas prospects. The Outer Hebrides Fault Zone (OHFZ) was largely active during the Caledonian Orogeny (ca. 430-400 Ma) at a deeper crustal level than the Ugandan rift faults. Initial dry conditions were followed by fluid ingress during deformation that controlled its rheological behaviour. The transition also altered the existing permeability. The OHFZ is a natural laboratory in which to study brittle fault rocks, and younger Mesozoic age faults may provide analogues for the West Shetland basin. Samples have been collected from both of these localities, and will be examined by optical and scanning electron microscopy. X-Ray micro-tomography will also be used to analyse the permeability characteristics of the fault rocks. Our understanding of fault zone permeability is crucial for a number of research areas, including earthquake geoscience, economic mineral formation, and hydrocarbon systems. As a result, this research has relevance to a variety of industry sectors, including oil and gas (and ccs), nuclear waste disposal, geothermal and mining.

  4. Variation in water disappearance, daily dose, and synovial fluid concentrations of tylvalosin and 3-O-acetyltylosin in commerical pigs during five day water medication with tylvalosin under field conditions.

    PubMed

    Canning, P; Bates, J; Skoland, K; Coetzee, J; Wulf, L; Rajewski, S; Wang, C; Gauger, P; Ramirez, A; Karriker, L

    2018-03-23

    Tylvalosin (TVN) is a water soluble macrolide used in swine production to treat enteric, respiratory, and arthritic pathogens. There is limited data on its distribution to synovial fluid beyond gavage studies, which do not represent field conditions. This study measured water disappearance, TVN concentration in the medicated water, daily dose, and concentrations of TVN and 3-O-acetyltylosin (3AT) in the synovial fluid and plasma of treated pigs over the administration period. The study emphasized understanding variation in tissue TVN concentrations within the context of a field setting. Sixty finisher pigs were housed individually with individual waterers. Six pigs were randomly allocated to the following time points for sample collection: 0, 48, 60, 72, 84, 96, 102, 108, 114, and 120 hr on medication. TVN was administered daily in the water for 5 days. Water disappearance and medicated water concentration were measured daily. At each time point, six pigs were euthanized and plasma and synovial fluid were collected for analysis. Median TVN synovial fluid concentrations ranged between <1 ng/ml (hour 0) to 3.6 ng/ml (hour 84). There was substantial variation between individual pigs for water disappearance (mean 4.36L and range 0-7.84). Median TVN water concentration was 59 ppm (range 38-75 ppm). © 2018 John Wiley & Sons Ltd.

  5. Detection and Molecular Characterization of Gemycircularvirus from Environmental Samples in Brazil.

    PubMed

    da Silva Assis, Matheus Ribeiro; Vieira, Carmen Baur; Fioretti, Julia Monassa; Rocha, Mônica Simões; de Almeida, Pedro Ivo Neves; Miagostovich, Marize Pereira; Fumian, Tulio Machado

    2016-12-01

    Gemycircularvirus (GemyCV) is a group of viruses which has been recently proposed as a new viral genus detected in fecal and environmental samples around the world. GemyCVs have been detected in human blood, brain tissue, cerebrospinal fluid, and stool sample. In the present study, we demonstrate for the first time, through molecular detection and characterization, the presence of GemyCVs in environmental samples from Brazil. Our results show a percentage of positivity ranging from 69 (25/36) to 97 % (35/36) in river water samples collected in Manaus, Amazon region, and wastewater from a wastewater treatment plant located in Rio de Janeiro, respectively, revealing GemyCVs as an important environmental contaminant.

  6. Determination of albumin in bronchoalveolar lavage fluid by flow-injection fluorometry using chromazurol S.

    PubMed

    Sato, Takaji; Saito, Yoshihiro; Chikuma, Masahiko; Saito, Yutaka; Nagai, Sonoko

    2008-03-01

    A highly sensitive flow injection fluorometry for the determination of albumin was developed and applied to the determination of albumin in human bronchoalveolar lavage fluids (BALF). This method is based on binding of chromazurol S (CAS) to albumin. The calibration curve was linear in the range of 5-200 microg/ml of albumin. A highly linear correlation (r=0.986) was observed between the albumin level in BALF samples (n=25) determined by the proposed method and by a conventional fluorometric method using CAS (CAS manual method). The IgG interference was lower in the CAS flow injection method than in the CAS manual method. The albumin level in BALF collected from healthy volunteers (n=10) was 58.5+/-13.1 microg/ml. The albumin levels in BALF samples obtained from patients with sarcoidosis and idiopathic pulmonary fibrosis were increased. This finding shows that the determination of albumin levels in BALF samples is useful for investigating lung diseases and that CAS flow injection method is promising in the determination of trace albumin in BALF samples, because it is sensitive and precise.

  7. Robotic transgastric cystgastrostomy and pancreatic debridement in the management of pancreatic fluid collections following acute pancreatitis.

    PubMed

    Kirks, Russell C; Sola, Richard; Iannitti, David A; Martinie, John B; Vrochides, Dionisios

    2016-01-01

    Pancreatic and peripancreatic fluid collections may develop after severe acute pancreatitis. Organized fluid collections such as pancreatic pseudocyst and walled-off pancreatic necrosis (WOPN) that mature over time may require intervention to treat obstructive or constitutional symptoms related to the size and location of the collection as well as possible infection. Endoscopic, open surgical and minimally invasive techniques are described to treat post-inflammatory pancreatic fluid collections. Surgical intervention may be required to treat collections containing necrotic pancreatic parenchyma or in locations not immediately apposed to the stomach or duodenum. Comprising a blend of the surgical approach and the clinical benefits of minimally invasive surgery, the robot-assisted technique of pancreatic cystgastrostomy with pancreatic debridement is described.

  8. Ridge-flank crustal microbiology investigated with long-term borehole observatories

    NASA Astrophysics Data System (ADS)

    Orcutt, B. N.; Bach, W.; Becker, K.; Edwards, K. J.; Fisher, A. T.; Haddad, A.; Hulme, S.; Teske, A.; Toner, B.; Wheat, C. G.

    2011-12-01

    The ridge flank environment represents an important habitat for microbial life on Earth, considering its size and chemical disequilibria between circulating fluids and rocks. However, the potential for this habitat to harbor life, and the characteristics that such life might have, are poorly known at present. Furthermore, the interactions of microbial communities across deep sediment-basement interfaces are not well-characterized. Subseafloor borehole observatories provide a novel platform for sampling and monitoring the microbiology of the crustal ridge flank environment. We present current results from a series of subsurface microbial colonization experiments using borehole observatories on the eastern flank of the Juan de Fuca Ridge, as well as analysis of samples collected on a transect away from a seawater-recharging seamount on this ridge flank. These results are compared to the microbiology of observatories installed in the Costa Rica Rift flank with similar fluid composition and temperatures (i.e. anoxic and warm). We will also discuss on-going experiments on the western-flank of the Mid-Atlantic Ridge, where formation fluids in basement are oxic and cool. Results from these experiments represent some of the extremes in crustal fluid conditions, paving the way for additional studies that are needed to address the importance of this biome as a carbon reservoir and a mechanism for crustal alteration.

  9. Electrolyte-Sensing Transistor Decals Enabled by Ultrathin Microbial Nanocellulose

    PubMed Central

    Yuen, Jonathan D.; Walper, Scott A.; Melde, Brian J.; Daniele, Michael A.; Stenger, David A.

    2017-01-01

    We report an ultra-thin electronic decal that can simultaneously collect, transmit and interrogate a bio-fluid. The described technology effectively integrates a thin-film organic electrochemical transistor (sensing component) with an ultrathin microbial nanocellulose wicking membrane (sample handling component). As far as we are aware, OECTs have not been integrated in thin, permeable membrane substrates for epidermal electronics. The design of the biocompatible decal allows for the physical isolation of the electronics from the human body while enabling efficient bio-fluid delivery to the transistor via vertical wicking. High currents and ON-OFF ratios were achieved, with sensitivity as low as 1 mg·L−1. PMID:28102316

  10. Electrolyte-Sensing Transistor Decals Enabled by Ultrathin Microbial Nanocellulose

    NASA Astrophysics Data System (ADS)

    Yuen, Jonathan D.; Walper, Scott A.; Melde, Brian J.; Daniele, Michael A.; Stenger, David A.

    2017-01-01

    We report an ultra-thin electronic decal that can simultaneously collect, transmit and interrogate a bio-fluid. The described technology effectively integrates a thin-film organic electrochemical transistor (sensing component) with an ultrathin microbial nanocellulose wicking membrane (sample handling component). As far as we are aware, OECTs have not been integrated in thin, permeable membrane substrates for epidermal electronics. The design of the biocompatible decal allows for the physical isolation of the electronics from the human body while enabling efficient bio-fluid delivery to the transistor via vertical wicking. High currents and ON-OFF ratios were achieved, with sensitivity as low as 1 mg·L-1.

  11. A population-based prevalence study of hepatitis A, B and C virus using oral fluid in Flanders, Belgium.

    PubMed

    Quoilin, Sophie; Hutse, Veronik; Vandenberghe, Hans; Claeys, Françoise; Verhaegen, Els; De Cock, Liesbet; Van Loock, Frank; Top, Geert; Van Damme, Pierre; Vranckx, Robert; Van Oyen, Herman

    2007-01-01

    Ten years after the first seroprevalence study performed in Flanders, the aim of this cross sectional study was to follow the evolution of hepatitis A, B and C prevalence. The prevalence of hepatitis A antibodies, hepatitis B surface antigen and hepatitis C antibodies was measured in oral fluid samples collected by postal survey. Using the National Population Register, an incremental sampling plan was developed to obtain a representative sampling of the general population. A total of 24,000 persons were selected and 6,000 persons among them contacted in a first wave. With 1834 participants a response rate of 30.6% was achieved. The prevalence was weighted for age and was 20.2% (95% CI 19.43-21.08) for hepatitis A, 0.66% (95% CI 0.51-0.84) for hepatitis B surface antigen and 0.12% (95% CI 0.09-0.39) for hepatitis C. The prevalence of hepatitis A and C in the Flemish population is lower in 2003 compared with the results of the study performed in 1993. The difference may be due to a real decrease of the diseases but also to differences in the methodology. The prevalence of hepatitis B surface antigen remains stable. Considering the 30% response rate and the high quality of the self-collected samples as reflect of a good participation of the general population, saliva test for prevalence study is a good epidemiological monitoring tool.

  12. 7-aminoclonazepam is superior to clonazepam for detection of clonazepam use in oral fluid by LC-MS/MS.

    PubMed

    Melanson, Stacy E F; Griggs, David; Bixho, Ida; Khaliq, Tahira; Flood, James G

    2016-04-01

    Clonazepam (CLON) is not only frequently prescribed in addiction management but is also commonly abused. Therefore many addiction clinics perform oral fluid (OF) testing, which unlike urine is not subject to adulteration, to monitor CLON compliance. However, CLON and other benzodiazepines can be challenging to detect in OF due to their weakly acidic nature and their presence in low concentrations. We determined the optimal technical and clinical approach for the detection of CLON use using OF. We measured CLON and its primary metabolite 7-aminoclonazepam (7AC) by liquid chromatography-tandem mass spectrometry in OF specimens over a 2 month period. The samples were collected using the Orasure Intercept OF sample collection device. One hundred samples were presumptive-positive for 7AC and/or CLON. 91 (91.0%) confirmed positive for 7AC (median, range: 4.2, 0.5-316.7 ng/ml) using the ion ratio test, while only 44 of the 100 (44.0%) samples confirmed positive for CLON (median, range: 3.7, 0.5-217.2 ng/ml) using the ion ratio test. In OF the levels of 7AC were approximately 2.4-fold higher than CLON. The use of 7AC as an analyte for the detection of both CLON compliance and undisclosed use is also recommended. 7AC should be the analyte measured in OF for the detection of CLON use. Copyright © 2016 Elsevier B.V. All rights reserved.

  13. Size-selective pulmonary dose indices for metal-working fluid aerosols in machining and grinding operations in the automobile manufacturing industry.

    PubMed

    Woskie, S R; Smith, T J; Hallock, M F; Hammond, S K; Rosenthal, F; Eisen, E A; Kriebel, D; Greaves, I A

    1994-01-01

    The current metal-working fluid exposures at three locations that manufacture automotive parts were assessed in conjunction with epidemiological studies of the mortality and respiratory morbidity experiences of workers at these plants. A rationale is presented for selecting and characterizing epidemiologic exposure groups in this environment. More than 475 full-shift personal aerosol samples were taken using a two-stage personal cascade impactor with median size cut-offs of 9.8 microns and 3.5 microns, plus a backup filter. For a sample of 403 workers exposed to aerosols of machining or grinding fluids, the mean total exposure was 706 micrograms/m3 (standard error (SE) = 21 micrograms/m3). Among 72 assemblers unexposed to machining fluids, the mean total exposure was 187 +/- 10 (SE) micrograms/m3. An analysis of variance model identified factors significantly associated with exposure level and permitted estimates of exposure for workers in the unsampled machine type/metal-working fluid groups. Comparison of the results obtained from personal impactor samples with predictions from an aerosol-deposition model for the human respiratory tract showed high correlation. However, the amount collected on the impactor stage underestimates extrathoracic deposition and overestimates tracheobronchial and alveolar deposition, as calculated by the deposition model. When both the impactor concentration and the deposition-model concentration were used to estimate cumulative thoracic concentrations for the worklives of a subset of auto workers, there was no significant difference in the rank order of the subjects' cumulative concentration. However, the cumulative impactor concentration values were significantly higher than the cumulative deposition-model concentration values for the subjects.

  14. 40 CFR Appendix 6 to Subpart A of... - Reverse Phase Extraction (RPE) Method for Detection of Oil Contamination in Non-Aqueous Drilling...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... rigorous statistical experimental design and interpretation (Reference 16.4). 14.0Pollution Prevention 14... fluids. 1.4This method has been designed to show positive contamination for 5% of representative crude....1Sample collection bottles/jars—New, pre-cleaned bottles/jars, lot-certified to be free of artifacts...

  15. 40 CFR Appendix 6 to Subpart A of... - Reverse Phase Extraction (RPE) Method for Detection of Oil Contamination in Non-Aqueous Drilling...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... rigorous statistical experimental design and interpretation (Reference 16.4). 14.0Pollution Prevention 14... fluids. 1.4This method has been designed to show positive contamination for 5% of representative crude....1Sample collection bottles/jars—New, pre-cleaned bottles/jars, lot-certified to be free of artifacts...

  16. 40 CFR Appendix 6 to Subpart A of... - Reverse Phase Extraction (RPE) Method for Detection of Oil Contamination in Non-Aqueous Drilling...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... rigorous statistical experimental design and interpretation (Reference 16.4). 14.0Pollution Prevention 14... fluids. 1.4This method has been designed to show positive contamination for 5% of representative crude....1Sample collection bottles/jars—New, pre-cleaned bottles/jars, lot-certified to be free of artifacts...

  17. 40 CFR Appendix 6 to Subpart A of... - Reverse Phase Extraction (RPE) Method for Detection of Oil Contamination in Non-Aqueous Drilling...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... rigorous statistical experimental design and interpretation (Reference 16.4). 14.0Pollution Prevention 14... oil contamination in drilling fluids. 1.4This method has been designed to show positive contamination....1Sample collection bottles/jars—New, pre-cleaned bottles/jars, lot-certified to be free of artifacts...

  18. Serum and gastric fluid levels of cytokines and nitrates in gastric diseases infected with Helicobacter pylori.

    PubMed

    Mehmet, N; Refik, M; Harputluoglu, M; Ersoy, Y; Aydin, N Engin; Yildirim, B

    2004-04-01

    This case control study presents data on the concentrations of nitrite and nitrate and a variety of pro-inflammatory cytokines such as interleukin-1 beta (IL-1 beta), interleukin-2R (IL-2R), interleukin-6 (IL-6), interleukin-8 (IL-8) and tumor necrosis factor TNF-alpha in gastric fluid and serum. Patients with gastritis, gastric ulcer and gastric cancer are studied and grouped according to infection by Helicobacter pylori. The 208 patients who underwent upper gastrointestinal endoscopic examination were classified as follows; H. pylori-positive gastritis (n = 32), H. pylori-negative gastritis (n = 32), H. pylori-positive ulcers (n = 34), H. pylori-negative ulcers (n = 34), 43 patients with H. pylori-positive gastric cancer in addition to 33 H. pylori-negative healthy control individuals. Gastric fluids and blood samples were taken concomitantly. Cytokines and nitrite and nitrate determinations were attempted as soon as possible after collection of the samples. Nitrite and nitrate levels of serum and gastric fluids of H. pylori-positive gastritis and ulcers were higher than H. pylori-negative gastritis and ulcers. The concentrations of total nitrite and nitrate and cytokines (TNF-alpha, IL-2R, IL-6, and IL-8) in gastric fluids and sera of H. pylori-positive gastric cancer patients were higher than H. pylori-negative control groups. IL-1 beta level was significantly elevated in gastric fluid of infected cancer patients but not in serum. Taken together, the results suggest that an increase in cytokine-NO combination in gastric mucosa previously reported by many studies is not restricted to local infected gastric tissue but also detected in gastric fluid and sera of H. pylori-positive subjects and may have an important role in the pathogenesis and development of common gastric diseases.

  19. Subgroups of haemodialysis patients in relation to fluid intake restrictions: a cluster analytical approach.

    PubMed

    Lindberg, Magnus; Wikström, Björn; Lindberg, Per

    2010-11-01

    To determine whether definable subgroups exist in a sample of haemodialysis patients with regard to self-efficacy, attentional style and depressive symptomatology and to compare whether interdialytic weight gain varies between patients in groups with different cognitive profiles. Theory-based research suggests that cognitive factors (e.g. self-efficacy and attentional style) and depressive symptomatology undermine adherence to health protective regimens. Preventing negative outcomes of fluid overload is essential for haemodialysis patients but many patients cannot achieve fluid control, and nursing interventions aimed to help the patients reduce fluid intake are ineffective. Understanding the interaction between cognitive factors and how this is related to adherence outcomes might therefore lead to the development of helpful nursing interventions. Explorative cross-sectional multicentre survey. The sample consisted of 133 haemodialysis patients. Data were collected using structured questionnaires. A brief self-report form and data on interdialytic weight gain was also used. Two-step cluster analysis was used to identify subgroups. One-way analysis of variance (anova) or Pearson's chi-square test was used for comparing subgroups. Three distinct subgroups were found and subsequently labelled: (1) low self-efficacy, (2) distraction and depressive symptoms and (3) high self-efficacy. The subgroups differed in fluid intake, but not in age, dialysis vintage, gender, residual urine output or in receiving any fluid intake advice. Clinically relevant subgroups of haemodialysis patients could be defined by their profiles regarding self-efficacy, attentional style and depressive symptoms. Based on this study, we would encourage clinical practitioners to take into account cognitive profiles while performing their work. This is especially important when a targeted nursing intervention, which aims to encourage and maintain the patient's fluid control, is introduced. © 2010 Blackwell Publishing Ltd.

  20. Supercritical carbon dioxide extraction of 2,4-dichlorophenol from food crop tissues.

    PubMed

    Thomson, C A; Chesney, D J

    1992-04-15

    Supercritical fluid extraction with carbon dioxide has been found to be effective for the isolation of residue levels (0.1-1 ppm) of 2,4-dichlorophenol from selected plant tissues. The 2,4-dichlorophenol residues were incompletely extracted with supercritical CO2 alone, since a substantial fraction of the 2,4-dichlorophenol was covalently attached to the plant matrix. An acid pretreatment procedure was developed to partially hydrolyze the plant tissue prior to extraction, releasing the bound 2,4-dichlorophenol residues. Steam distillation showed higher residue levels for field-treated straw samples. This is attributed to the greater degree of hydrolysis inherent in the steam distillation procedure. Supercritical CO2 extraction of field-treated seed samples showed higher levels of 2,4-dichlorophenol residues than did steam distillation. The supercritical fluid extractant was able to solvate 2,4-dichlorophenol residues in the interior of the seed and transport them to the surface for collection. The aqueous medium used in steam distillation was unable to penetrate the hydrophobic seed matrix to the same degree. While the actual extraction time experienced in supercritical fluid extraction was far less than that of steam distillation (45 min vs 6 h, respectively), the total sample preparation time was similar in both methods.

  1. Recurrent oil sheens at the deepwater horizon disaster site fingerprinted with synthetic hydrocarbon drilling fluids.

    PubMed

    Aeppli, Christoph; Reddy, Christopher M; Nelson, Robert K; Kellermann, Matthias Y; Valentine, David L

    2013-08-06

    We used alkenes commonly found in synthetic drilling-fluids to identify sources of oil sheens that were first observed in September 2012 close to the Deepwater Horizon (DWH) disaster site, more than two years after the Macondo well (MW) was sealed. While explorations of the sea floor by BP confirmed that the well was sound, they identified the likely source as leakage from an 80-ton cofferdam, abandoned during the operation to control the MW in May 2010. We acquired sheen samples and cofferdam oil and analyzed them using comprehensive two-dimensional gas chromatography. This allowed for the identification of drilling-fluid C16- to C18-alkenes in sheen samples that were absent in cofferdam oil. Furthermore, the spatial pattern of evaporative losses of sheen oil alkanes indicated that oil surfaced closer to the DWH wreckage than the cofferdam site. Last, ratios of alkenes and oil hydrocarbons pointed to a common source of oil found in sheen samples and recovered from oil-covered DWH debris collected shortly after the explosion. These lines of evidence suggest that the observed sheens do not originate from the MW, cofferdam, or from natural seeps. Rather, the likely source is oil in tanks and pits on the DWH wreckage, representing a finite oil volume for leakage.

  2. Diagnosis of Streptococcus pneumoniae and Haemophilus influenzae type b meningitis by identifying DNA from cerebrospinal fluid-impregnated filter paper strips.

    PubMed

    Peltola, Heikki; Roine, Irmeli; Leinonen, Maija; Kuisma, Leena; Mata, Antonio González; Arbo, Antonio; Goyo, José; Saukkoriipi, Annika

    2010-02-01

    Bacterial meningitis remains often etiologically unconfirmed, especially in resource-poor settings. We tested the potential of real-time polymerase chain reaction to identify Streptococcus pneumoniae (Pnc) and Haemophilus influenzae type b (Hib) from cerebrospinal fluid impregnated on filter paper strips. Pnc and Hib genome equivalents were blindly quantified by polymerase chain reaction from 129 liquid cerebrospinal fluid (CSF) samples-the standard-and strips stored at room temperature for months. Genome counts were compared by simple regression. The strips showed a sensitivity and specificity of 92% and 99% for Pnc, and of 70% and 100% for Hib, respectively. The positive and negative predictive values were 94% and 97% for Pnc, and 100% and 89% for Hib, respectively. For Pnc, the positive and negative likelihood ratio was 92 and 0.08, and the overall accuracy 98%, whereas for Hib they were 70 and 0.30, and 91%, respectively. Genome counting showed good correlation between the filter paper and liquid CSF samples, r(2) being 0.87 for Pnc and 0.68 for Hib (P < 0.0001 for both). Although not replacing bacterial culture, filter paper strips offer an easy way to collect and store CSF samples for later bacteriology. They can also be transported in standard envelops by regular mail.

  3. Methane Distribution In Plumes Of The South Mariana Back-arc Spreading Center

    NASA Astrophysics Data System (ADS)

    Toki, T.; Hirota, A.; Tsunogai, U.; Gamo, T.; Nakamura, K.; Noguchi, T.; Taira, N.; Oomori, T.; Ishibashi, J.; Utsumi, M.

    2004-12-01

    In the South Mariana Back-arc Spreading Center, two methane plumes were observed in water column based on analysis of methane in seawater samples collected during the R/V Thompson expeditions in 2003 around water depth of 2,700 m over the Fryer site on the ridge-axis seamount (12\\deg57.22N, 143\\deg37.16E, depth: 2,850 m). The estimated end-member isotopic compositions of methane in the two plumes are \\delta13C_{CH4} = -5‰ PDB and -50‰ PDB. These values indicated that the two plumes were originated from the different sources. During YK03-09 cruise using the submersible Shinkai 6500 from October to November in 2003, detailed seafloor observation discovered sulfide chimneys emitting black and clear hydrothermal fluid on the off-axis seamount at Pika site (12°55.15N, 143°36.96E, depth: 2,773 m). The result of analysis of isotopic composition of methane in the hydrothermal fluids recovered from the off-axis hydrothermal vents using WHATS (Water and Hydrothermal Atsuryoku Tight Sampler) was averaged value of -4‰ PDB (standard deviation = 1‰ PDB, n = 3). Hydrothermal fluids from the Fryer site were also sampled and were measured: average value = -6.7‰ PDB, standard deviation = 0.3‰ PDB, n = 3. During the R/V Thompson expeditions in March 2004 using ROV ROPOS, 11 ROPOS dives and CTD-RMS plume surveys were conducted, and newly discovered a huge hydrothermal structure with active fluid venting at Achaean site on the ridge skirt (12°56.37N, 143°37.92E, depth: 2,990 m). The δ ^{13}C_{CH4} value of the fluid sample from the site using ROCS (Rotary Clean Seawater sampler) was -14.7‰ PDB. Analysis of isotopic composition of methane in the plume samples collected using the CTD-hydrocast at water depth of 2,500 m over the Archaean site showed -45‰ PDB. Source of methane (δ ^{13}C_{CH4} = -50‰ PDB), however, in the two plumes of the South Mariana Back-arc Spreading Center has been missing. The δ ^{13}C of methane cannot be considered in sediment-starved seafloor hydrothermal fluids as the results from an abiogenic reaction in magma. Alternative explanation would be the secondary stimulated plume of methane that is formed in invertebrate guts of zooplankton swarmed about microbes in the plume, as proposed about a subsurface CH_{4} maximum in the upper oceanic water column. The secondary methane plume may be associated with methane plume without a corresponding enrichment in ^{3}He, observed in the Mariana Trough Back-arc basin at 14° N.

  4. Hyaluronic acid synthase-2 gene transfer into the joints of Beagles by use of recombinant adeno-associated viral vectors.

    PubMed

    Kyostio-Moore, Sirkka; Berthelette, Patricia; Cornell, Cathleen Sookdeo; Nambiar, Bindu; Figueiredo, Monica Dias

    2018-05-01

    OBJECTIVE To evaluate gene transfer of recombinant adeno-associated viral (rAAV) vectors with AAV2 or AAV5 capsid and encoding hyaluronic acid (HA) synthase-2 (HAS2) into joints of healthy dogs. ANIMALS 22 purpose-bred Beagles. PROCEDURES Plasmid expression cassettes encoding canine HAS2 (cHAS2) were assessed in vitro for concentration and molecular size of secreted HA. Thereafter, rAAV2-cHAS2 vectors at 3 concentrations and rAAV5-cHAS2 vectors at 1 concentration were each administered intra-articularly into the left stifle joint of 5 dogs; 2 dogs received PBS solution instead. Synovial fluid HA concentration and serum and synovial fluid titers of neutralizing antibodies against AAV capsids were measured at various points. Dogs were euthanized 28 days after treatment, and cartilage and synovium samples were collected for vector DNA and mRNA quantification and histologic examination. RESULTS Cell transfection with plasmids encoding cHAS2 resulted in an increase in production and secretion of HA in vitro. In vivo, the rAAV5-cHAS2 vector yielded uniform genome transfer and cHAS2 expression in collected synovium and cartilage samples. In contrast, rAAV2-cHAS2 vectors were detected inconsistently in synovium and cartilage samples and failed to produce clear dose-related responses. Histologic examination revealed minimal synovial inflammation in joints injected with rAAV vectors. Neutralizing antibodies against AAV capsids were detected in serum and synovial fluid samples from all vector-treated dogs. CONCLUSIONS AND CLINICAL RELEVANCE rAAV5-mediated transfer of the gene for cHAS2 into healthy joints of dogs by intra-articular injection appeared safe and resulted in vector-derived cHAS2 production by synoviocytes and chondrocytes. Whether this treatment may increase HA production by synoviocytes and chondrocytes in osteoarthritic joints remains to be determined.

  5. Perfluorooctanoate: Placental and lactational transport pharmacokinetics in rats.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hinderliter, Paul M.; Mylchreest, E.; Gannon, S. A.

    This study was conducted to develop a quantitative understanding of the potential for gestational and lactational transfer of perfluorooctanoate (PFOA) in the rat. Time-mated female rats were dosed by oral gavage once daily at concentrations of 3, 10, or 30 mg/kg/day of the ammonium salt of PFOA (APFO) starting on gestation (G) day 4 and continuing until sacrifice. On days 10, 15, and 21G, five rats per dose level were sacrificed and blood samples were collected 2h post-dose. Embryos were collected on day 10G, amniotic fluid, placentas, and embryos/fetuses were collected on days 15 and 21G, and fetal blood samplesmore » were collected on day 21G. Five rats per dose level were allowed to deliver and nurse their litters, and on days 3, 7, 14, and 21 post-partum (PP) milk and blood samples of maternal and pup were collected 2h post-dose. All samples were analyzed by high-performance liquid chromatography-mass spectrometry (HPLC-MS) for PFOA concentration. Concentrations of PFOA in maternal plasma and milk attained steady state during the sampling interval. The steady-state concentrations in maternal plasma were 10-15, 25-30, and 60-75 microg/mL in rats receiving 3, 10, and 30 mg/kg, respectively. Steady-state concentrations in milk were approximately 10 times less than those in maternal plasma. The concentration of PFOA in fetal plasma on day 21G was approximately half the steady-state concentration in maternal plasma. The milk concentrations appeared to be generally comparable to the concentrations in pup plasma. Pup plasma concentrations decreased from day 3PP to day 7PP, and were similar on days 7, 14, and 21PP at all dose levels. PFOA was detected in placenta (days 15 and 21G), amniotic fluid (days 15 and 21G), embryo (days 10 and 15G), and fetus (day 21G). These pharmacokinetics allow estimation of the dose to developing and nursing rat offspring following maternal exposure.« less

  6. Third-space fluid distribution of pemetrexed in non-small cell lung cancer patients.

    PubMed

    Honoré, Per Hartvig; Joensen, Sigrid Jóhansdóttir; Olsen, Michelle; Hansen, Steen Honoré; Mellemgaard, Anders

    2014-08-01

    Hydrophilic drugs particularly those with low plasma protein binding may accumulate in third-space fluid in the body. Cytotoxic drugs like methotrexate (MTX) cause damage in the tissue, and evacuation of the third-space fluid in pleura is strongly recommended before new dosing. Pemetrexed (PEM) is a multi-targeted antifolate similar to MTX approved for the treatment for malignant pleural mesothelioma and non-small cell lung cancer. Current recommendations for patients receiving treatment with PEM prescribe draining of the pleural fluid. This is based upon the recommendations for MTX and not directly to any specific findings relating to PEM. The recommendations are the same because PEM is an analogue of MTX; the molecular structures and pharmacokinetic parameters are similar. However, since draining the pleural fluid is painful and cancer patient are particularly susceptible to infection subsequently, it is relevant to examine the recommendations for PEM explicitly. Eight patients treated with a 500 mg/m(2) PEM combined with platinum salt were examined. Plasma samples were first collected in relation to the start of PEM infusion. Thereafter, plasma and pleura samples were taken at various times after drug infusion from each patient; in two patients, sampling was done twice but on different occasions. The quantitative determination of PEM was performed with reversed-phase high-performance liquid chromatography, and sample preparation was performed using protein precipitation with perchloric acid. Pharmacokinetic analysis was performed using a non-compartment method as well a two-compartment model. The results were calculated from 10 samples taken from eight patients, where data from one patient point were excluded as the patient had impaired renal function, and three samples were reported as below limit of quantification. The plasma PEM pharmacokinetics calculated showed an elimination half-life (t ½ elimination) of 3.2 h and distribution half-life (t ½-distribution) of 6 min. Clearance (CL) was 5.1 L/h, central volume of distribution (V(central)) 23.2 L and peripheral volume distribution (V(peripheral)) 10.6 L, and the area under the curve was 186 μg h/mL. Using non-compartment methods, an elimination half-life of 3.1 h and an apparent CL of 3.2 L/h were measured, whereas an apparent steady-state volume became 14.2 L. The pleura concentrations were only half of simultaneous plasma concentrations, and elimination half-life was 3.15 h. Pemetrexed is not likely to accumulate in the pleural fluid, and evacuation of fluid might not be necessary. Further investigation is needed to recommend no drainage of the fluid, i.e., in patients with renal impairment.

  7. Ureaplasma species and Mycoplasma hominis in cervical fluid of pregnancies complicated by preterm prelabor rupture of membranes.

    PubMed

    Musilova, Ivana; Pliskova, Lenka; Kutova, Radka; Hornychova, Helena; Jacobsson, Bo; Kacerovsky, Marian

    2016-01-01

    To evaluate Ureaplasma species and Mycoplasma hominis DNA in the cervical fluid and their association with microbial invasion of the amniotic cavity (MIAC) and/or histological chorioamnionitis (HCA) in pregnancies complicated by preterm prelabor rupture of membranes (PPROM). A prospective study of 68 women with singleton pregnancies complicated by PPROM between 24(0/7) and 36(6/7) weeks was conducted. Cervical fluid and amniotic fluid were collected from all women at the time of admission. The Ureaplasma species and Mycoplasma hominis DNA in the cervical fluid were identified using specific real-time PCR. Ureaplasma species and Mycoplasma hominis DNA were identified in 59% (40/69) of the cervical fluid samples. Women with the presence of Ureaplasma species DNA with and without Mycoplasma hominis DNA in the cervical fluid had a higher rate of MIAC alone [35% (14/40) versus 11% (3/28); p = 0.02] and a higher rate of the presence of both MIAC and HCA [30% (12/40) versus 4% (1/28); p = 0.01] than women without Ureaplasma species and Mycoplasma hominis DNA in the cervical fluid. The presence of Ureaplasma species DNA with and without Mycoplasma hominis DNA in the cervical fluid is associated with a higher risk of MIAC or MIAC and HCA together in pregnancies complicated by PPROM.

  8. Measuring temporal variability in pore-fluid chemistry to assess gas hydrate stability: development of a continuous pore-fluid array.

    PubMed

    Lapham, Laura L; Chanton, Jeffrey P; Martens, Christopher S; Higley, Paul D; Jannasch, Hans W; Woolsey, J Robert

    2008-10-01

    A specialized pore-fluid array (PFA) sampler was designed to collect and store pore fluids to monitor temporal changes of ions and gases in gas hydrate bearing sediments. We tested the hypothesis that pore-fluid chemistry records hydrate formation or decomposition events and reflects local seismic activity. The PFA is a seafloor probe that consists of an interchangeable instrument package that houses OsmoSamplers, long-term pore-fluid samplers, a specialized low-dead volume fluid coupler, and eight sample ports along a 10 m sediment probe shaft. The PFA was deployed at Mississippi Canyon 118, a Gulf of Mexico hydrate site. A 170 day record was acquired from the overlying water and 1.3 m below seafloor (mbsf). Fluids were measured for dissolved chloride, sulfate, and methane concentrations and dissolved inorganic carbon and methane stable carbon and deuterium isotope ratios. Chloride and sulfate did not change significantly over time, suggesting the absence of gas hydrate formation or decomposition events. Over the temporal record, methane concentrations averaged 4 mM at 1.3 mbsf, and methane was thermogenic in origin (delta13C-CH4 = -32.4 +/- 3.4 per thousand). The timing of an anomalous 14 mM methane spike coincided with a nearby earthquake (Mw = 5.8), consistent with the hypothesis that pore-fluid chemistry reflects seismic events.

  9. Effectiveness of a fluid chart in outpatient management of suspected dengue fever: A pilot study.

    PubMed

    Nasir, Nazrila Hairin; Mohamad, Mohazmi; Lum, Lucy Chai See; Ng, Chirk Jenn

    2017-01-01

    Dengue infection is the fastest spreading mosquito-borne viral disease in the world. One of the complications of dengue is dehydration which, if not carefully monitored and treated, may lead to shock, particularly in those with dengue haemorrhagic fever. WHO has recommended oral fluid intake of five glasses or more for adults who are suspected to have dengue fever. However, there have been no published studies looking at self-care intervention measures to improve oral fluid intake among patients suspected of dengue fever. To assess the feasibility and effectiveness of using a fluid chart to improve oral fluid intake in patients with suspected dengue fever in a primary care setting. This feasibility study used a randomized controlled study design. The data was collected over two months at a primary care clinic in a teaching hospital. The inclusion criteria were: age > 12 years, patients who were suspected to have dengue fever based on the assessment by the primary healthcare clinician, fever for > three days, and thrombocytopenia (platelets < 150 x 109/L). Both groups received a dengue home care card. The intervention group received the fluid chart and a cup (200ml). Baseline clinical and laboratory data, 24-hour fluid recall (control group), and fluid chart were collected. The main outcomes were: hospitalization rates, intravenous fluid requirement and total oral fluid intake. Among the 138 participants who were included in the final analysis, there were fewer hospital admissions in the intervention group (n = 7, 10.0%) than the control group (n = 12, 17.6%) (p = 0.192). Similarly, fewer patients (n = 9, 12.9%) in the intervention group required intravenous fluid compared to the control group (n = 15, 22.1%), (p = 0.154). There was an increase in the amount of daily oral fluid intake in the intervention group (about 3,000 ml) compared to the control group (about 2,500 ml, p = 0.521). However, these differences did not reach statistical significance. This is a feasible and acceptable study to perform in a primary care setting. The fluid chart is a simple, inexpensive tool that may reduce hospitalization and intravenous fluid requirement in suspected dengue patients. A randomized controlled trial with larger sample size is needed to determine this conclusively. International Standard Randomized Controlled Trial Number (ISRCTN) Registry ISRCTN25394628 http://www.isrctn.com/ISRCTN25394628.

  10. Advanced statistical analysis of Raman spectroscopic data for the identification of body fluid traces: semen and blood mixtures.

    PubMed

    Sikirzhytski, Vitali; Sikirzhytskaya, Aliaksandra; Lednev, Igor K

    2012-10-10

    Conventional confirmatory biochemical tests used in the forensic analysis of body fluid traces found at a crime scene are destructive and not universal. Recently, we reported on the application of near-infrared (NIR) Raman microspectroscopy for non-destructive confirmatory identification of pure blood, saliva, semen, vaginal fluid and sweat. Here we expand the method to include dry mixtures of semen and blood. A classification algorithm was developed for differentiating pure body fluids and their mixtures. The classification methodology is based on an effective combination of Support Vector Machine (SVM) regression (data selection) and SVM Discriminant Analysis of preprocessed experimental Raman spectra collected using an automatic mapping of the sample. This extensive cross-validation of the obtained results demonstrated that the detection limit of the minor contributor is as low as a few percent. The developed methodology can be further expanded to any binary mixture of complex solutions, including but not limited to mixtures of other body fluids. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  11. Pleiotrophin, the angiogenic and mitogenic growth factor: levels in serum and synovial fluid in rheumatoid arthritis and osteoarthritis : And correlation with clinical, laboratory and radiological indices.

    PubMed

    Fadda, S M H; Bassyouni, I H; Khalifa, R H; Elsaid, N Y

    2018-05-01

    Few studies have reported a possible involvement of pleiotrophin (PTN) in the pathophysiology of osteoarthritis (OA) and very little is known about its role in rheumatoid arthritis (RA). This study is to measure PTN in the sera and synovial fluids in RA and OA and to assess its relation to activity, functional class and radiological staging. Serum and synovial fluid samples were collected from 35 RA patients and 40 knee OA patients and serum samples were withdrawn from 20 healthy controls. Demographic, clinical and serological data were prospectively assessed. Functional and radiographic grades were also assessed. Serum and synovial fluid PTN levels were measured using enzyme-linked immunosorbent assay (ELISA). There was no statistical significant differences (p > 0.05) on comparing the mean PTN level in sera of RA, OA patients and healthy controls. However the mean synovial fluid level of PTN in both patient groups was significantly higher than mean serum level (p < 0.001). Significant correlations between the serum PTN level and both morning stiffness duration (p = 0.008) and mHAQ score (p = 0.039) were only observed in RA patients. Our results point to a possible important role of PTN in RA and OA. We firstly report a serological pattern of PTN in the sera and synovial fluids of RA patients. However its implementation as a disease marker or a potential target therapy in both diseases awaits larger studies and further investigations.

  12. The in vitro reduction of sodium [36Cl]chlorate in bovine ruminal fluid.

    PubMed

    Oliver, C E; Bauer, M L; Caton, J S; Anderson, R C; Smith, D J

    2007-08-01

    Sodium chlorate effectively reduces or eliminates gram-negative pathogenic bacteria in the gastrointestinal tracts of live cattle. Limitations to the in vivo efficacy of chlorate are its rapid absorption from the gastrointestinal tract and its presumed reduction to chloride within the gastrointestinal tract. We hypothesized that chlorate would be reduced via ruminal bacteria in a ruminal in vitro system and that the reduction of chlorate would be influenced by the dietary for-age:concentrate ratio; thus, 4 ruminally cannulated steers were fed 20 or 80% concentrate diets in a crossover design. Ruminal fluid was collected in 2 periods and dispensed into in vitro tubes containing sodium [36Cl]chlorate, which was sufficient for 100 or 300 mg/L final chlorate concentrations. The tubes were incubated for 0, 1, 4, 8, 16, or 24 h; autoclaved, control ruminal fluid, fortified with sodium [36Cl]chlorate, was incubated for 24 h. Chlorate remaining in each sample was measured by liquid scintillation counting after [36Cl]chloride was precipitated with silver nitrate. A preliminary study indicated that chlorite, a possible intermediate in the reduction of chlorate, had a half-life of approximately 4.5 min in freshly collected (live) ruminal fluid; chlorite was, therefore, not specifically measured in ruminal incubations. The chlorate dose did not affect in vitro DM digestion (P > or = 0.11), whereas in vitro DM digestibility was decreased (P < or = 0.05) by 80% forage content. By 24 h, 57.5 +/- 2.6% of the chlorate remained in 100-mg/L incubations, whereas 78.2 +/- 2.6% of the chlorate remained in the 300-mg/L incubations. When the data were expressed on a concentration basis (mg/L), diet had no effect (P > or = 0.18) on chlorate reduction; however, when chlorate reduction was expressed on a percentage basis, chlorate reduction tended to be greater (P > or = 0.09) at 8 and 16 h in the incubations containing the low-concentrate diet. Chlorate remaining in autoclaved controls at 24 h was intermediate (P < 0.01) between chlorate remaining in live ruminal fluid samples incubated for 0 or 24 h. Attempts to isolate chlorate-respiring bacteria from 2 sources of ruminal fluid were not successful. These data indicate that microbial-dependent or chemical-dependent, or both, reduction of chlorate occurs in bovine ruminal fluid and that dietary concentrate had a negligible effect on chlorate reduction.

  13. The geochemical controls on vent fluids from the Lucky Strike vent field, Mid-Atlantic Ridge

    NASA Astrophysics Data System (ADS)

    Von Damm, K. L.; Bray, A. M.; Buttermore, L. G.; Oosting, S. E.

    1998-08-01

    Hydrothermal vent fluids were collected from the Lucky Strike site at 37°17'N on the Mid-Atlantic Ridge in both 1993 and 1996. Seven vents were sampled with the DSV Alvin in 1993 and six vents were sampled in 1996 using the ROV Jason during the LUSTRE '96 Cruise. As three of the vents were sampled in both 1993 and in 1996, a time series of vent fluid chemistry is also reported. Measured temperatures ranged from 202 to 333°C at the 1618-1726 m depth of the vent field, which is located on Lucky Strike Seamount. These fluids are either equal to or less than the local bottom seawater in chlorinity. While the range in fluid compositions at Lucky Strike is generally within that observed elsewhere, the unusual aspects of the fluid chemistries are the relatively high pH and low Fe, Mn, Li and Zn. We attribute this, as well as an usually low Sr/Ca ratio, to reaction with a highly altered substrate. The high Si and Cu contents suggest a deep, as well as hot, source for these fluids. The fluid compositions therefore suggest formation by super-critical phase separation at a depth not less than 1300 m below the seafloor, and reaction with a relatively oxic, and previously altered, substrate. There is temporal variability in some of the vent fluid compositions as Li, K, Ca and Fe concentrations have increased in some of the vents, as has the Fe/Mn (molar) ratio, although the chlorinities have remained essentially constant from 1993 to 1996. While there is not a simple relationship between vent fluid compositions (or temperatures) and distance from the lava lake at the summit of the seamount, the vent fluids from many of the vents can be shown to be related to others, often at distances >200 m. The most southeasterly vents (Eiffel Tower and the Marker/Mounds vents) are distinct in chlorinity and other chemical parameters from the rest of the vents, although closely related to each other within the southeastern area. Similarly all of the vents not in this one area, appear closely related to each other. This suggests one or two source fluids for many of the vents, as is also inferred to be the case at TAG, but which is in contrast to observations on faster spreading ridges. This may suggest inherently different plumbing for hydrothermal systems at slower versus faster spreading ridges.

  14. False-negative rate of gram-stain microscopy for diagnosis of septic arthritis: suggestions for improvement.

    PubMed

    Stirling, Paul; Faroug, Radwane; Amanat, Suheil; Ahmed, Abdulkhaled; Armstrong, Malcolm; Sharma, Pankaj; Qamruddin, Ahmed

    2014-01-01

    We quantify the false-negative diagnostic rate of septic arthritis using Gram-stain microscopy of synovial fluid and compare this to values reported in the peer-reviewed literature. We propose a method of improving the diagnostic value of Gram-stain microscopy using Lithium Heparin containers that prevent synovial fluid coagulation. Retrospective study of the Manchester Royal Infirmary microbiology database of patients undergoing synovial fluid Gram-stain and culture between December 2003 and March 2012 was undertaken. The initial cohort of 1896 synovial fluid analyses for suspected septic arthritis was reduced to 143 after exclusion criteria were applied. Analysis of our Gram-stain microscopy yielded 111 false-negative results from a cohort size of 143 positive synovial fluid cultures, giving a false-negative rate of 78%. We report a false-negative rate of Gram-stain microscopy for septic arthritis of 78%. Clinicians should therefore avoid the investigation until a statistically significant data set confirms its efficacy. The investigation's value could be improved by using Lithium Heparin containers to collect homogenous synovial fluid samples. Ongoing research aims to establish how much this could reduce the false-negative rate.

  15. Bacterial community under the hydrothermal system on the Suiyo Seamount: A model for archean and exo-biota

    NASA Astrophysics Data System (ADS)

    Yamagishi, A.

    Microbial community in hydrothermal area at seafloor has been analyzed by culture-independent methods. Hydrothermal fluid from natural vents and vent chimneys have been analyzed by PCR (1-2). Hyperthermophilic microbes have been isolated from these environments (3-4). Though the analysis of these samples can provide the window to penetrate the microbial community under the seafloor, more direct analysis is desired for better understanding of the sub-seafloor microbial community In the ``Archaean Park Project'' supported by Special Coordination Fund, several holes were drilled and the holes were supported by casing pipes in the crater of the Suiyo seamount on the Izu-Bonin arc, West Pacific Ocean (about 1,400 m depth) in 2001 and 2002. Hydrothermal fluids were sampled from cased holes. The fluids were filtered to collect the microbial cells. The DNA was extracted and used to amplify 16S rDNA fragments by PCR (polymerase chain reaction) using a bacteria and an archaea specific primer sets. The PCR fragments were cloned and sequenced. FISH analysis revealed from 6 x103 to 2.5 x 106 bactrerial cells/ml in these hydrothermal fluids. PCR clone-analysis showed significant variation in bacterial sequences found in these samples. The species-patterns suggest that the contamination of ambient seawater to hydrothermal fluid samples is negligible. Difference in the dominant species depending on the location was found, suggesting that the bacterial community at sub-sea floor is not monotonous but has gradual shift from the hydrothermal center to peripheral area. The results suggest that there is chemo-autotrophic microbe-dependent biota under the hydrothermal system. References 1) Takai et al. Genetics 152: 1285-1297 (1999) 2) Takai et al. Appl. Environ. Microbioi. 67: 3618-3629 (2001) 3) Summit et al. Proc. Natl. Acad. Sci. 98: 2158-2163 (2001) 4) Amend, J. P. and Shodk, E. L. FEMS Microbiol. Rev. 25: 175-243 (2002)

  16. Dual diaphragm tank with telltale drain

    NASA Technical Reports Server (NTRS)

    Tuthill, Wallace C., Jr. (Inventor)

    1991-01-01

    A fluid storage and expulsion system comprising a tank with an internal flexible diaphragm assembly of dual diaphragms in back-to-back relationship, at least one of which is provided with a patterned surface having fine edges such that the diaphragms are in contact along said edges without mating contact of surface areas to thereby form fluid channels which extend outwardly to the peripheral edges of the diaphragms is described. The interior wall of the tank at the juncture of tank sections is formed with a circumferential annular recess comprising an outer annular recess portion which forms a fluid collection chamber and an inner annular recess portion which accommodates the peripheral edge portions of the diaphragms and a sealing ring in clamped sealing relation therebetween. The sealing ring is perforated with radially extending passages which allow any fluid leaking or diffusing past a diaphragm to flow through the fluid channels between the diaphragms to the fluid collection chamber. Ports connectable to pressure fittings are provided in the tank sections for admission of fluids to opposite sides of the diaphragm assembly. A drain passage through the tank wall to the fluid collection chamber permits detection, analysis and removal of fluids in the collection chamber.

  17. Geochemical processes governing the compositional features of the crater fumarolic field at Mt. Etna

    NASA Astrophysics Data System (ADS)

    Liotta, Marcello; Paonita, Antonio; Caracausi, Antonio; Martelli, Mauro; Rizzo, Andrea; Favara, Rocco

    2010-05-01

    Mt Etna is one of the most-active volcanoes in the world. It is characterized by major eruptions, frequent Strombolian activity, and ash emissions. The volcano summit consists of the central crater of Voragine surrounded by the three active cones of the North-East Crater, Bocca Nuova, and the South-East Crater. They are characterized by very fractured and unstable edges. Under these conditions most of the fractures represent preferential degassing pathways for volcanic fluids, so that the main fumarolic fields develop in such fractured areas. The geochemistry of the fumaroles at the summit area of Mt. Etna was investigated. Fumarolic samples were collected between June 2008 and August 2009. Gas samples were usually collected as 'dry gas' and analyzed for the concentrations of He, H2, O2, N2, CO, CH4, and CO2. Fumarolic gases were also sampled a few times using the classical Giggenbach bottles and Giggenbach-type bottles filled with ammonia and silver nitrate in order to determine the SO2/H2S ratio. In addition a novel method was employed in order to sample fumaroles characterized by high content of atmospheric gases. Two types of fumaroles were identified: low-temperature fumaroles, which are dominated by CO2 with minor amounts of SO2 and H2S, and negligible halogen contents, and high-temperature fumaroles, which are strongly air-contaminated and characterized by appreciable amounts of volcanogenic carbon, sulfur, and chlorine. Our data clearly indicate that secondary processes modify the composition of the fluids once they leave the magma body. A model based on thermodynamic data is proposed to explore such postmagmatic processes. We computed the equilibrium composition of magmatic gases that cool starting from magmatic temperatures under several pressure conditions. The model, which uses Etnean plume geochemistry as starting composition of fluids exsolved from magma, shows that SO2 and H2S control the redox conditions of the gas mixture during the cooling, until the reactions involving CO/CO2 and H2/H2O ratios are fully quenched. The scrubbing processes occurring subsequent to condensation and gas-liquid water interaction allow total removal of HCl and partial removal of sulfur species. During the ascent toward the surface, the concentration of CH4 increases in all fumaroles due to a modest contribution from hydrothermal fluid. A geochemical model for the interaction of pristine magmatic fluids with shallower systems is proposed. The model explains geochemical changes at the crater fumaroles in terms of variable hydrothermal and magmatic contributions, and modified thermodynamic conditions.

  18. Use of vitamin B12 in joint lavage for determination of dilution factors of canine synovial fluid.

    PubMed

    de Bruin, Tanya; de Rooster, Hilde; van Bree, Henri; Cox, Eric

    2005-11-01

    To test a modified saline (0.9% NaCl) solution joint washing (lavage) technique that includes the use of vitamin B12 as an internal marker for the evaluation of synovial fluid dilution in lavage samples from canine joints. 9 plasma samples obtained from blood samples of 9 healthy dogs and 9 synovial fluid samples aspirated from stifle joints of 9 cadaveric dogs. Photometric absorbances of 25% vitamin B12 solution, canine synovial fluid, and canine plasma were measured in a spectrophotometer to establish an optimal wavelength for analysis. Canine synovial fluid and plasma samples were mixed with the 25% vitamin B12 solution to obtain 1%, 3%, 5%, 10%, 20%, and 50% solutions of synovial fluid or plasma. Diluted synovial fluid and plasma samples were used to simulate joint lavage samples and to examine the possible interference of these substances (synovial fluid or plasma) with the absorbance of the 25% vitamin B12 solution in photometric analysis. The optimal wavelength was found to be at 550 nm. Canine synovial fluid and plasma samples did not interfere with the absorbance measurements of the 25% vitamin B12 solution up to a 50% dilution of plasma or synovial fluid. The modified saline solution joint lavage method with the use of a 25% vitamin B12 solution as an internal standard provides an accurate and reliable technique for the evaluation of synovial fluid dilution in lavage samples from canine joints.

  19. A clinical evaluation of a new Silastic seminal fluid collection device.

    PubMed

    Mehan, D J; Chehval, M J

    1977-06-01

    A new Silastic seminal fluid collection device has been tested clinically and comparison studies have been made with both the polyethylene sheath and commercial latex condoms. In a series of 100 patients, the Silastic seminal fluid device has been found to be superior to the polyethylene sheath with regard to patient comfort and also has had greater reliability. In comparison with the latex device, the Silastic seminal fluid collection device is nearly as comfortable and has been found to be far more reliable.

  20. Evaluation of borehole geophysical and video logs, at Butz Landfill Superfund Site, Jackson Township, Monroe County, Pennsylvania

    USGS Publications Warehouse

    Low, Dennis J.; Conger, Randall W.

    2001-01-01

    Between February 1996 and November 2000, geophysical logging was conducted in 27 open borehole wells in and adjacent to the Butz Landfill Superfund Site, Jackson Township, Monroe County, Pa., to determine casing depth and depths of water-producing zones, water-receiving zones, and zones of vertical borehole flow. The wells range in depth from 57 to 319 feet below land surface. The geophysical logging determined the placement of well screens and packers, which allow monitoring and sampling of water-bearing zones in the fractured bedrock so that the horizontal and vertical distribution of contaminated ground water migrating from known sources could be determined. Geophysical logging included collection of caliper, natural-gamma, single-point-resistance, fluid-resistivity, fluid-temperature, and video logs. Caliper and video logs were used to locate fractures, joints, and weathered zones. Inflections on single-point-resistance, fluid-temperature, and fluid-resistivity logs indicated possible water-bearing fractures, and heatpulse-flowmeter measurements verified these locations. Natural-gamma logs provided information on stratigraphy.

  1. Towards an automatic lab-on-valve-ion mobility spectrometric system for detection of cocaine abuse.

    PubMed

    Cocovi-Solberg, David J; Esteve-Turrillas, Francesc A; Armenta, Sergio; de la Guardia, Miguel; Miró, Manuel

    2017-08-25

    A lab-on-valve miniaturized system integrating on-line disposable micro-solid phase extraction has been interfaced with ion mobility spectrometry for the accurate and sensitive determination of cocaine and ecgonine methyl ester in oral fluids. The method is based on the automatic loading of 500μL of oral fluid along with the retention of target analytes and matrix clean-up by mixed-mode cationic/reversed-phase solid phase beads, followed by elution with 100μL of 2-propanol containing (3% v/v) ammonia, which are online injected into the IMS. The sorptive particles are automatically discarded after every individual assay inasmuch as the sorptive capacity of the sorbent material is proven to be dramatically deteriorated with reuse. The method provided a limit of detection of 0.3 and 0.14μgL -1 for cocaine and ecgonine methyl ester, respectively, with relative standard deviation values from 8 till 14% with a total analysis time per sample of 7.5min. Method trueness was evaluated by analyzing oral fluid samples spiked with cocaine at different concentration levels (1, 5 and 25μgL -1 ) affording relative recoveries within the range of 85±24%. Fifteen saliva samples were collected from volunteers and analysed following the proposed automatic procedure, showing a 40% cocaine occurrence with concentrations ranging from 1.3 to 97μgL -1 . Field saliva samples were also analysed by reference methods based on lateral flow immunoassay and gas chromatography-mass spectrometry. The application of this procedure to the control of oral fluids of cocaine consumers represents a step forward towards the development of a point-of-care cocaine abuse sensing system. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Three cases of mumps virus and enterovirus coinfection in children with enteroviral meningitis

    PubMed Central

    Rasti, Mojtaba; Makvandi, Manoochehr; Neisi, Niloofar; Azaran, Azarakhsh; Rastegarvand, Nasrin; Khalafkhany, Davod; Jahangirnezhad, Emad; Teimoori, Ali; Hadian, Maryam; Shabani, Abdolnabi; Shamsizadeh, Ahmad; Nikfar, Roya; Varnaseri, Mehran

    2016-01-01

    Abstract Several viruses are responsible for aseptic meningitis; however, in the region of Southwest Iran, the role played by each virus is still not very well known. The aim of this study is to determine the relative frequencies of mumps virus, herpes viruses, and enteroviruses, as well as coinfections among them, in patients with aseptic meningitis. In this cross-sectional study, samples of cerebrospinal fluid were collected between December 2012 and December 2013 from patients under 14 years, who were hospitalized in Abuzar Children's Hospital in Ahvaz, Southwest Iran (the only children's hospital in Khuzestan province and Southwest Iran). All 66 cerebrospinal fluid samples and corresponding clinical data were collected from patients with aseptic meningitis by specialists, and with the patients’ consent. The DNA and RNA were extracted from these samples and subjected to polymerase chain reaction as well as reverse transcription polymerase chain reaction (RT-PCR) for detection of mumps virus, herpes viruses, and enteroviruses. Nine of the samples (3 mumps-positive and 6 enterovirus-positive) were sequenced. The mumps virus sequences were investigated for possible mutations in the SH and partial HN regions. Up to 39 patients (59.09%) were found to be positive for enteroviruses, 3 (4.5%) for mumps virus, and 1 (1.5%) for herpes viruses (specifically, the varicella-zoster virus). Two patients (3.03%) had a mumps virus and enterovirus coinfection. Among the 3 detected mumps virus samples, 1 belonged to genotype B, while the others belonged to genotype N. Six sequenced enteroviruses indicated the highest similarity with Echovirus 30. An amino acid substitution at position 51 (N→T) was detected in the HN region of genotype N mumps virus samples, in comparison to the reference strain. PMID:27930588

  3. Three cases of mumps virus and enterovirus coinfection in children with enteroviral meningitis.

    PubMed

    Rasti, Mojtaba; Makvandi, Manoochehr; Neisi, Niloofar; Azaran, Azarakhsh; Rastegarvand, Nasrin; Khalafkhany, Davod; Jahangirnezhad, Emad; Teimoori, Ali; Hadian, Maryam; Shabani, Abdolnabi; Shamsizadeh, Ahmad; Nikfar, Roya; Varnaseri, Mehran

    2016-12-01

    Several viruses are responsible for aseptic meningitis; however, in the region of Southwest Iran, the role played by each virus is still not very well known. The aim of this study is to determine the relative frequencies of mumps virus, herpes viruses, and enteroviruses, as well as coinfections among them, in patients with aseptic meningitis.In this cross-sectional study, samples of cerebrospinal fluid were collected between December 2012 and December 2013 from patients under 14 years, who were hospitalized in Abuzar Children's Hospital in Ahvaz, Southwest Iran (the only children's hospital in Khuzestan province and Southwest Iran).All 66 cerebrospinal fluid samples and corresponding clinical data were collected from patients with aseptic meningitis by specialists, and with the patients' consent. The DNA and RNA were extracted from these samples and subjected to polymerase chain reaction as well as reverse transcription polymerase chain reaction (RT-PCR) for detection of mumps virus, herpes viruses, and enteroviruses. Nine of the samples (3 mumps-positive and 6 enterovirus-positive) were sequenced. The mumps virus sequences were investigated for possible mutations in the SH and partial HN regions.Up to 39 patients (59.09%) were found to be positive for enteroviruses, 3 (4.5%) for mumps virus, and 1 (1.5%) for herpes viruses (specifically, the varicella-zoster virus). Two patients (3.03%) had a mumps virus and enterovirus coinfection. Among the 3 detected mumps virus samples, 1 belonged to genotype B, while the others belonged to genotype N. Six sequenced enteroviruses indicated the highest similarity with Echovirus 30. An amino acid substitution at position 51 (N→T) was detected in the HN region of genotype N mumps virus samples, in comparison to the reference strain.

  4. Quantification of penicillin G during labor and delivery by capillary electrophoresis.

    PubMed

    Thomas, Andrea; Ukpoma, Omon K; Inman, Jennifer A; Kaul, Anil K; Beeson, James H; Roberts, Kenneth P

    2008-04-24

    In this study, a capillary electrophoresis (CE) method was developed as a means to measure levels of penicillin G (PCN G) in Group B Streptococcus (GBS) positive pregnant women during labor and delivery. Volunteers for this developmental study were administered five million units of PCN G at the onset of labor. Urine, blood, and amniotic fluid samples were collected during labor and post delivery. Samples were semi-purified by solid-phase extraction (SPE) using Waters tC18 SepPak 3cc cartridges with a sodium phosphate/methanol step gradient for elution. Capillary electrophoresis or reversed-phase high-performance liquid chromatography (RP-HPLC) with diode-array absorbance detection were used to separate the samples in less than 30 min. Quantification was accomplished by establishing a calibration curve with a linear dynamic range. The tC18 SPE methodology provided substantial sample clean-up with high recovery yields of PCN G ( approximately 90%). It was found that SPE was critical for maintaining the integrity of the separation column when using RP-HPLC, but was not necessary for sample analysis by CE where no stationary phase is present. Quantification results ranged from millimolar concentrations of PCN G in maternal urine to micromolar concentrations in amniotic fluid. Serum and cord blood levels of PCN G were below quantification limits, which is likely due to the prolonged delay in sample collection after antibiotic administration. These results show that CE can serve as a simple and effective means to characterize the pharmacokinetic distribution of PCN G from mother to unborn fetus during labor and delivery. It is anticipated that similar methodologies have the potential to provide a quick, simple, and cost-effective means of monitoring the clinical efficacy of PCN G and other drugs during pregnancy.

  5. The complexity of oral physiology and its impact on salivary diagnostics.

    PubMed

    Helmerhorst, E J; Dawes, C; Oppenheim, F G

    2018-04-01

    Saliva contains biomarkers for systemic as well as oral diseases. This study was undertaken to assess the variability in the sources of such biomarkers (plasma, cells) and attempted to identify saliva deterioration markers in order to improve saliva diagnostic outcomes. Inter- and intrasubject variations in salivary gingival crevicular fluid levels were determined by measuring salivary albumin and transferrin levels. The purity of collected glandular secretions was determined by bacterial culture, and the variability in epithelial cell numbers by cell counting and optical density measurement. Saliva sample deterioration markers were identified by RP-HPLC and LC-ESI-MS/MS. Tenfold variations were observed in plasma-derived albumin and transferrin levels, emphasizing the need for biomarker normalization with respect to plasma contributions to saliva. Epithelial cell levels varied 50-fold in samples collected before and after a meal. Salivary fungal levels varied within subjects and among subjects from 0 to >1,000 colony-forming units per milliliter. In saliva samples incubated for various time intervals at 37°C, five peptides were identified that steadily increased in intensity over time and which could be explored as "deterioration markers." Taking saliva characteristics appropriately into account will help realize the promise that this body fluid is suitable to be exploited for reliable healthcare monitoring and surveillance. Published 2017. This article is a U.S. Government work and is in the public domain in the USA.

  6. Measurement of total antioxidant capacity in gingival crevicular fluid and serum in dogs with periodontal disease.

    PubMed

    Pavlica, Zlatko; Petelin, Milan; Nemec, Alenka; Erzen, Damjan; Skaleric, Uros

    2004-11-01

    To determine whether gingival crevicular fluid (GCF) and serum total antioxidant capacities (TACs) correlate with the degree of severity of periodontal disease in dogs. 41 Toy and Miniature Poodles. After assessment of the degree of severity of naturally occurring periodontitis, GCF samples from both maxillary fourth premolars and a blood sample were collected from each dog. The condition of the periodontium of the entire dentition and at each site of GCF collection was recorded. Clinical parameters assessed included plaque index, gingival index, and probing depth. Radiographic analysis of alveolar bone level was also performed. Total antioxidant capacity was measured in GCF and serum samples by use of a commercial kit. Dogs with gingivitis and minimal periodontitis had significantly higher TAC in GCF than dogs with advanced periodontitis. Bivariate regression analysis revealed significant negative correlations between TAC in GCF and clinical parameters and age. The TAC in serum was significantly negatively correlated with the degree of gingival inflammation but was not significantly correlated with age. TAC in GCF is related to the degree of severity of periodontal disease in dogs. This is likely the result of release of reactive oxygen species by activated phagocytes and fibroblasts in the inflamed periodontal tissues. The results of our study suggest that the local delivery of antioxidants may be a useful adjunctive treatment for periodontitis in dogs.

  7. Multielemental analysis of 18 essential and toxic elements in amniotic fluid samples by ICP-MS: Full procedure validation and estimation of measurement uncertainty.

    PubMed

    Markiewicz, B; Sajnóg, A; Lorenc, W; Hanć, A; Komorowicz, I; Suliburska, J; Kocyłowski, R; Barałkiewicz, D

    2017-11-01

    Amniotic fluid is the substantial factor in the development of an embryo and fetus due to the fact that water and solutes contained in it penetrate the fetal membranes in an hydrostatic and osmotic way as well as being swallowed by the fetus. Elemental composition of amniotic fluid influences the growth and health of the fetus, therefore, an analysis of amniotic fluid is important because the results would indicate abnormal levels of minerals or toxic elements. Inductively coupled plasma mass spectroscopy (ICP-MS) is often used for determination of trace and ultra-trace level elements in a wide range of matrices including biological samples because of its unique analytical capabilities. In the case of trace and ultra-trace level analysis detailed characteristics of analytical procedure as well as properties of the analytical result are particularly important. The purpose of this study was to develop a new analytical procedure for multielemental analysis of 18 elements (Al, As, Ba, Ca, Cd, Co, Cr, Cu, Mg, Mn, Ni, Pb, Sb, Se, Sr, U, V and Zn) in amniotic fluid samples using ICP-MS. Dynamic reaction cell (DRC) with two reaction gases, ammonia and oxygen, was involved in the experiment to eliminate spectral interferences. Detailed validation was conducted using 3 certified reference mterials (CRMs) and real amniotic fluid samples collected from patients. Repeatability for all analyzed analytes was found to range from 0.70% to 8.0% and for intermediate precision results varied from 1.3% to 15%. Trueness expressed as recovery ranged from 80% to 125%. Traceability was assured through the analyses of CRMs. Uncertainty of the results was also evaluated using single-laboratory validation approach. The obtained expanded uncertainty (U) results for CRMs, expressed as a percentage of the concentration of an analyte, were found to be between 8.3% for V and 45% for Cd. Standard uncertainty of the precision was found to have a greater influence on the combined standard uncertainty than on trueness factor. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Contrasting fluid/rock interaction between the Notch Peak granitic intrusion and argillites and limestones in western Utah: evidence from stable isotopes and phase assemblages

    USGS Publications Warehouse

    Nabelek, P.I.; Labotka, T.C.; O'Neil, J.R.; Papike, J.J.

    1984-01-01

    The Jurassic Notch Peak granitic stock, western Utah, discordantly intrudes Cambrian interbedded pure limestones and calcareous argillites. Contact metamorphosed argillite and limestone samples, collected along traverses away from the intrusion, were analyzed for ??18O, ??13C, and ??D. The ??13C and ??18O values for the limestones remain constant at about 0.5 (PDB) and 20 (SMOW), respectively, with increasing metamorphic grade. The whole rock ??18O values of the argillites systematically decrease from 19 to as low as 8.1, and the ??13C values of the carbonate fraction from 0.5 to -11.8. The change in ??13C values can be explained by Rayleigh decarbonation during calcsilicate reactions, where calculated {Mathematical expression} is about 4.5 permil for the high-grade samples and less for medium and low-grade samples suggesting a range in temperatures at which most decarbonation occurred. However, the amount of CO2 released was not anough to decrease the whole rock ??18O to the values observed in the argillites. The low ??18O values close to the intrusion suggest interaction with magmatic water that had a ??18O value of 8.5. The extreme lowering of ??13C by fractional devolatilization and the lowering of ??18O in argillites close to the intrusion indicates oxgen-equivalent fluid/rock ratios in excess of 1.0 and X(CO2)F of the fluid less than 0.2. Mineral assemblages in conjunction with the isotopic data indicate a strong influence of water infiltration on the reaction relations in the argillites and separate fluid and thermal fronts moving thru the argillites. The different stable isotope relations in limestones and argillites attest to the importance of decarbonation in the enhancement of permeability. The flow of fluids was confined to the argillite beds (argillite aquifers) whereas the limestones prevented vertical fluid flow and convective cooling of the stock. ?? 1984 Springer-Verlag.

  9. Recovery of spiked Δ9-tetrahydrocannabinol in oral fluid from polypropylene containers.

    PubMed

    Molnar, Anna; Lewis, John; Fu, Shanlin

    2013-04-10

    Oral fluid is currently used by Australian and international law enforcement agencies and employers to detect recent use of cannabis and other drugs of abuse. The main psychoactive constituent of cannabis, Δ(9)-tetrahydrocannabinol (THC), is highly lipophilic and losses occur when in contact with plastic, possibly due to its adsorption onto the plastic surface. This study aims to investigate factors governing the interaction of THC with plastic and search for ways of overcoming such interaction so to improve THC recovery. As polypropylene is one of the most common types of plastic used in collection devices, it was the focus of this study. All experiments were done by preparing neat oral fluid samples spiked with THC in 2-mL polypropylene centrifuge tubes. Samples were transferred with or without prior addition of Triton(®) X-100 (0.25%) to glass tubes containing d3-THC as internal standard and 0.1M phosphate buffer was then added. Samples were extracted by liquid-liquid extraction using hexane/ethyl acetate (9:1, v/v), dried and analysed by gas chromatography-mass spectrometry (GC-MS) after derivatisation. No significant difference was found in terms of THC loss to plastic when the concentration ranged from 25 to 1000 ng/mL in the same volume of oral fluid. Varying the oral fluid volume (0.5-1.5 mL) while keeping THC at a constant concentration showed an upward trend with more loss associated with lower volumes. The use of Triton(®) X-100 significantly decreased the adherence of THC to the plastic tubes and increased the THC transfer (>96%) at all volumes tested. Degradation of THC during storage was also studied over a 4-week period and it was found that azide did not seem to play a significant role in preserving THC in oral fluid. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  10. Dual quantification of dapivirine and maraviroc in cervicovaginal secretions from ophthalmic tear strips and polyester-based swabs via liquid chromatographic-tandem mass spectrometric (LC-MS/MS) analysis.

    PubMed

    Parsons, Teresa L; Emory, Joshua F; Seserko, Lauren A; Aung, Wutyi S; Marzinke, Mark A

    2014-09-01

    Topical microbicidal agents are being actively pursued as a modality to prevent HIV viral transmission during sexual intercourse. Quantification of antiretroviral agents in specimen sources where antiviral activity is elicited is critical, and drug measurements in cervicovaginal fluid can provide key information on local drug concentrations. Two antiretroviral drugs, dapivirine and maraviroc, have gained interest as vaginal microbicidal agents, and rugged methods are required for their quantification in cervicovaginal secretions. Cervicovaginal fluid spiked with dapivirine and maraviroc were applied to ophthalmic tear strips or polyester-based swabs to mimic collection procedures used in clinical studies. Following sample extraction and the addition of isotopically labeled internal standards, samples were subjected to liquid chromatographic-tandem mass spectrometric (LC-MS/MS) analysis using a Waters BEH C8, 50mm×2.1mm, 1.7μm particle size column, on an API 4000 mass analyzer operated in selective reaction monitoring mode. The method was validated according to FDA Bioanalytical Method Validation guidelines. Due to the disparate saturation capacity of the tested collection devices, the analytical measuring ranges for dapivirine and maravirocin cervicovaginal fluid on the ophthalmic tear strip were 0.05-25ng/tear strip, and 0.025-25ng/tear strip, respectively. As for the polyester-based swab, the analytical measuring ranges were 0.25-125ng/swab for dapivirine and 0.125-125ng/swab for maraviroc. Dilutional studies were performed for both analytes to extended ranges of 25,000ng/tear strip and 11,250ng/swab. Standard curves were generated via weighted (1/x(2)) linear or quadratic regression of calibrators. Precision, accuracy, stability and matrix effects studies were all performed and deemed acceptable according to the recommendations of the FDA Bioanalytical Method Validation guidelines. A rugged LC-MS/MS method for the dual quantification of dapivirine and maraviroc in cervicovaginal fluid using two unique collection devices has been developed and validated. The described method meets the criteria to support large research trials. Copyright © 2014 Elsevier B.V. All rights reserved.

  11. Dual Quantification of Dapivirine and Maraviroc in Cervicovaginal Secretions from Ophthalmic Tear Strips and Polyester-Based Swabs via Liquid Chromatographic-Tandem Mass Spectrometric (LC-MS/MS) Analysis

    PubMed Central

    Parsons, Teresa L.; Emory, Joshua F.; Seserko, Lauren A.; Aung, Wutyi S.; Marzinke, Mark A.

    2014-01-01

    Background Topical microbicidal agents are being actively pursued as a modality to prevent HIV viral transmission during sexual intercourse. Quantification of antiretroviral agents in specimen sources where antiviral activity is elicited is critical, and drug measurements in cervicovaginal fluid can provide key information on local drug concentrations. Two antiretroviral drugs, dapivirine and maraviroc, have gained interest as vaginal microbicidal agents, and rugged methods are required for their quantification in cervicovaginal secretions. Methods Cervicovaginal fluid spiked with dapivirine and maraviroc were applied to ophthalmic tear strips or polyester-based swabs to mimic collection procedures used in clinical studies. Following sample extraction and the addition of isotopically-labeled internal standards, samples were subjected to liquid chromatographic-tandem mass spectrometric (LC-MS/MS) analysis using a Waters BEH C8, 50 × 2.1 mm, 1.7 µm particle size column, on an API 4000 mass analyzer operated in selective reaction monitoring mode. The method was validated according to FDA Bioanalytical Method Validation guidelines. Results Due to the disparate saturation capacity of the tested collection devices, the analytical measuring ranges for dapivirine and maravirocin cervicovaginal fluid on the ophthalmic tear strip were 0.05 to 25 ng/tear strip, and 0.025 to 25 ng/tear strip, respectively. As for the polyester-based swab, the analytical measuring ranges were 0.25 to 125 ng/swab for dapivirine and 0.125 to 125 ng/swab for maraviroc. Dilutional studies were performed for both analytes to extended ranges of 25,000 ng/tear strip and 11,250 ng/swab. Standard curves were generated via weighted (1/x2) linear or quadratic regression of calibrators. Precision, accuracy, stability and matrix effects studies were all performed and deemed acceptable according to the recommendations of the FDA Bioanalytical Method Validation guidelines. Conclusions A rugged LC-MS/MS method for the dual quantification of dapivirine and maraviroc in cervicovaginal fluid using two unique collection devices has been developed and validated. The described method meets the criteria to support large research trials. PMID:25005891

  12. Helium and carbon gas geochemistry of pore fluids from the sediment-rich hydrothermal system in Escanaba Trough

    USGS Publications Warehouse

    Ishibashi, J.-I.; Sato, M.; Sano, Y.; Wakita, H.; Gamo, T.; Shanks, Wayne C.

    2002-01-01

    Ocean Drilling Program (ODP) Leg 169, which was conducted in 1996 provided an opportunity to study the gas geochemistry in the deeper part of the sediment-rich hydrothermal system in Escanaba Trough. Gas void samples obtained from the core liner were analyzed and their results were compared with analytical data of vent fluid samples collected by a submersible dive program in 1988. The gas geochemistry of the pore fluids consisted mostly of a hydrothermal component and was basically the same as that of the vent fluids. The He isotope ratios (R/RA = 5.6-6.6) indicated a significant mantle He contribution and the C isotopic compositions of the hydrocarbons [??13C(CH4) = -43???, ??13C(C2H6) = -20???] were characterized as a thermogenic origin caused by hydrothermal activity. On the other hand, the pore fluids in sedimentary layers away from the hydrothermal fields showed profiles which reflected lateral migration of the hydrothermal hydrocarbons and abundant biogenic CH4. Helium and C isotope systematics were shown to represent a hydrothermal component and useful as indicators for their distribution beneath the seafloor. Similarities in He and hydrocarbon signatures to that of the Escanaba Trough hydrothermal system were found in some terrestrial natural gases, which suggested that seafloor hydrothermal activity in sediment-rich environments would be one of the possible petroleum hydrocarbon generation scenarios in unconventional geological settings. ?? 2002 Elsevier Science Ltd. All rights reserved.

  13. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fong, Erika J.; Huang, Chao; Hamilton, Julie

    Here, a major advantage of microfluidic devices is the ability to manipulate small sample volumes, thus reducing reagent waste and preserving precious sample. However, to achieve robust sample manipulation it is necessary to address device integration with the macroscale environment. To realize repeatable, sensitive particle separation with microfluidic devices, this protocol presents a complete automated and integrated microfluidic platform that enables precise processing of 0.15–1.5 ml samples using microfluidic devices. Important aspects of this system include modular device layout and robust fixtures resulting in reliable and flexible world to chip connections, and fully-automated fluid handling which accomplishes closed-loop sample collection,more » system cleaning and priming steps to ensure repeatable operation. Different microfluidic devices can be used interchangeably with this architecture. Here we incorporate an acoustofluidic device, detail its characterization, performance optimization, and demonstrate its use for size-separation of biological samples. By using real-time feedback during separation experiments, sample collection is optimized to conserve and concentrate sample. Although requiring the integration of multiple pieces of equipment, advantages of this architecture include the ability to process unknown samples with no additional system optimization, ease of device replacement, and precise, robust sample processing.« less

  14. A histological study of the seminal vesicle of the armoured catfish Corydoras aeneus.

    PubMed

    Franceschini-Vicentini, I B; Papa, L P; Bombonato, M T S; Vicentini, C A; Ribeiro, K; Orsi, A M

    2007-04-01

    Most species of Corydoras exhibited a reproductive behaviour called 'T-position', and exhibited an accessory gland in the male genital tract, called the seminal vesicle. It appeared that both the structure and the composition of the fluid varied considerably between the species investigated. Consequently, different opinions were proposed regarding the possible role of seminal vesicle on this particular reproductive behaviour. Male adults of Corydoras aeneus were collected, anaesthetized, and samples of seminal vesicle were fixed in Bouin's solution. The sections were stained with haematoxylin-eosin and periodic acid Schiff. The seminal vesicle showed a system of anastomosed secretory tubules, forming a vesicular collective network, which gave rise to the vesicular ducts. The latter fused with the testicular efferent ducts and formed the spermatic ducts. Considering this fusion, when the sperm cells reached the spermatic ducts, the fluid produced at the seminal vesicle covered them. Histochemical studies evidenced the presence of neutral and acid glycosaminoglycans in the seminal fluid. Considering the reproductive behaviour of C. aeneus, it is believed that the protection associated with the immobilization of the sperm cells assures the sperm integrity during the passage through female's intestine until fertilization.

  15. Comparative evaluation of the indigenous microbial diversity vs. drilling fluid contaminants in the NEEM Greenland ice core.

    PubMed

    Miteva, Vanya; Burlingame, Caroline; Sowers, Todd; Brenchley, Jean

    2014-08-01

    Demonstrating that the detected microbial diversity in nonaseptically drilled deep ice cores is truly indigenous is challenging because of potential contamination with exogenous microbial cells. The NEEM Greenland ice core project provided a first-time opportunity to determine the origin and extent of contamination throughout drilling. We performed multiple parallel cultivation and culture-independent analyses of five decontaminated ice core samples from different depths (100-2051 m), the drilling fluid and its components Estisol and Coasol, and the drilling chips collected during drilling. We created a collection of diverse bacterial and fungal isolates (84 from the drilling fluid and its components, 45 from decontaminated ice, and 66 from drilling chips). Their categorization as contaminants or intrinsic glacial ice microorganisms was based on several criteria, including phylogenetic analyses, genomic fingerprinting, phenotypic characteristics, and presence in drilling fluid, chips, and/or ice. Firmicutes and fungi comprised the dominant group of contaminants among isolates and cloned rRNA genes. Conversely, most Proteobacteria and Actinobacteria originating from the ice were identified as intrinsic. This study provides a database of potential contaminants useful for future studies of NEEM cores and can contribute toward developing standardized protocols for contamination detection and ensuring the authenticity of the microbial diversity in deep glacial ice. © 2014 Federation of European Microbiological Societies. Published by John Wiley & Sons Ltd. All rights reserved.

  16. Pine needle abortion biomarker detected in bovine fetal fluids.

    PubMed

    Snider, Douglas B; Gardner, Dale R; Janke, Bruce H; Ensley, Steven M

    2015-01-01

    Pine needle abortion is a naturally occurring condition in free-range cattle caused by the consumption of pine needles from select species of cypress, juniper, pine, and spruce trees. Confirmatory diagnosis of pine needle abortion has previously relied on a combined case history of pine needle consumption and detection of isocupressic acid in a sample from the dam. Stable metabolites of isocupressic acid include agathic acid, dihydroagathic acid, and tetrahydroagathic acid, which have been shown to be present in the serum of mature animals for a few days following consumption of pine needles. As maternal serum is infrequently submitted for diagnosis of cattle abortions, a diagnostic assay capable of confirming isocupressic acid exposure in other matrices would be desirable. To the authors' knowledge, no previous investigations have indicated whether these stable metabolites of isocupressic acid cross the placenta or are detectable in fetal tissues. Therefore, the presence of agathic acid, dihydroagathic acid, and tetrahydroagathic acid was evaluated using gas chromatography-mass spectroscopy on fetal thoracic fluid and stomach contents collected from 2 aborted bovine fetuses with a recent herd history of pine needle consumption by the dams and a subsequent abortion outbreak in the herd. Only tetrahydroagathic acid was detected in the fetal thoracic fluid and fetal stomach contents. The current study encourages diagnosticians to collect fetal thoracic fluids to permit the detection of tetrahydroagathic acid in cases of suspected pine needle abortion. © 2014 The Author(s).

  17. Microbial community structure of hydrothermal deposits from geochemically different vent fields along the Mid-Atlantic Ridge

    USGS Publications Warehouse

    Flores, Gilberto E.; Campbell, James H.; Kirshtein, Julie D.; Meneghin, Jennifer; Podar, Mircea; Steinberg, Joshua I.; Seewald, Jeffrey S.; Tivey, Margaret Kingston; Voytek, Mary A.; Yang, Zamin K.; Reysenbach, Anna-Louise

    2011-01-01

    To evaluate the effects of local fluid geochemistry on microbial communities associated with active hydrothermal vent deposits, we examined the archaeal and bacterial communities of 12 samples collected from two very different vent fields: the basalt-hosted Lucky Strike (37°17'N, 32°16.3'W, depth 1600-1750m) and the ultramafic-hosted Rainbow (36°13'N, 33°54.1'W, depth 2270-2330m) vent fields along the Mid-Atlantic Ridge (MAR). Using multiplexed barcoded pyrosequencing of the variable region 4 (V4) of the 16S rRNA genes, we show statistically significant differences between the archaeal and bacterial communities associated with the different vent fields. Quantitative polymerase chain reaction (qPCR) assays of the functional gene diagnostic for methanogenesis (mcrA), as well as geochemical modelling to predict pore fluid chemistries within the deposits, support the pyrosequencing observations. Collectively, these results show that the less reduced, hydrogen-poor fluids at Lucky Strike limit colonization by strict anaerobes such as methanogens, and allow for hyperthermophilic microaerophiles, like Aeropyrum. In contrast, the hydrogen-rich reducing vent fluids at the ultramafic-influenced Rainbow vent field support the prevalence of methanogens and other hydrogen-oxidizing thermophiles at this site. These results demonstrate that biogeographical patterns of hydrothermal vent microorganisms are shaped in part by large scale geological and geochemical processes.

  18. Puberty timing and fluid intelligence: a study of correlations between testosterone and intelligence in 8- to 12-year-old Chinese boys.

    PubMed

    Shangguan, Fangfang; Shi, Jiannong

    2009-08-01

    Sex hormone such as testosterone was recently recognized as an important contributor of spatial cognition and intelligence during development, but the relationship between puberty timing and intelligence especially in children is largely unknown. Here in this study, we investigated the potential relationship between the level of sex hormones in saliva and fluid intelligence in 8- to 12-year-old Chinese boys. Fluid intelligence was measured by the Cattell's Culture Fair Intelligence Test. 1600 children aged 8-12 years were included in the Cattell's Culture Fair Intelligence Test and saliva samples were collected thereafter from 166 boys with normal intelligence distribution, composed of 49, 54 and 63 boys in 8-, 10- and 12-year-old group respectively. The level of salivary testosterone and estradiol was measured with enzyme-immunoassay technique. Data of BMI and age were collected. The relationship between the level of salivary sex hormones and fluid intelligence was analysed by correlation test. There was no significant correlation between salivary testosterone level and fluid intelligence in 8-year-old boys, whereas there was a significant positive correlation in 10-year-old boys and a significant negative correlation in 12-year-old boys between those two variable. To verify the correlation, we performed stepwise multivariate linear regression and discriminant analysis, with both the age and BMI of the boys and their parents, and salivary estradiol level considered. The results showed that the level of testosterone and intelligence was correlated, and the correlation was much stronger when the level of salivary testosterone was higher than 14 pg/ml. In summary, the study suggests that the relationship of testosterone and intelligence varies from late childhood to early adolescence, and the puberty timing is closely related with fluid intelligence.

  19. Shape matters: Near-field fluid mechanics dominate the collective motions of ellipsoidal squirmers.

    PubMed

    Kyoya, K; Matsunaga, D; Imai, Y; Omori, T; Ishikawa, T

    2015-12-01

    Microswimmers show a variety of collective motions. Despite extensive study, questions remain regarding the role of near-field fluid mechanics in collective motion. In this paper, we describe precisely the Stokes flow around hydrodynamically interacting ellipsoidal squirmers in a monolayer suspension. The results showed that various collective motions, such as ordering, aggregation, and whirls, are dominated by the swimming mode and the aspect ratio. The collective motions are mainly induced by near-field fluid mechanics, despite Stokes flow propagation over a long range. These results emphasize the importance of particle shape in collective motion.

  20. Viscoelasticity promotes collective swimming of sperm

    NASA Astrophysics Data System (ADS)

    Tung, Chih-Kuan; Harvey, Benedict B.; Fiore, Alyssa G.; Ardon, Florencia; Suarez, Susan S.; Wu, Mingming

    From flocking birds to swarming insects, interactions of organisms large and small lead to the emergence of collective dynamics. Here, we report striking collective swimming of bovine sperm, with sperm orienting in the same direction within each cluster, enabled by the viscoelasticity of the fluid. A long-chain polyacrylamide solution was used as a model viscoelastic fluid such that its rheology can be fine-tuned to mimic that of bovine cervical mucus. In viscoelastic fluid, sperm formed dynamic clusters, and the cluster size increased with elasticity of the polyacrylamide solution. In contrast, sperm swam randomly and individually in Newtonian fluids of similar viscosity. Analysis of the fluid motion surrounding individual swimming sperm indicated that sperm-fluid interaction is facilitated by the elastic component of the fluid. We note that almost all biological fluids (e.g. mucus and blood) are viscoelastic in nature, this finding highlights the importance of fluid elasticity in biological function. We will discuss what the orientation fluctuation within a cluster reveals about the interaction strength. Supported by NIH Grant 1R01HD070038.

  1. Impact of Flow Rate, Collection Devices, and Extraction Methods on Tear Concentrations Following Oral Administration of Doxycycline in Dogs and Cats.

    PubMed

    Sebbag, Lionel; Showman, Lucas; McDowell, Emily M; Perera, Ann; Mochel, Jonathan P

    2018-04-30

    Compare the precision of doxycycline quantification in tear fluid collected with either Schirmer strips or polyvinyl acetal (PVA) sponges following oral drug administration. Three dogs and 3 cats were administered doxycycline orally at a dose of 4.2-5 mg/kg every 12 h for 6 consecutive days. At day 5 and 6, blood and tear fluid were sampled to capture doxycycline trough and maximal concentrations. Tear fluid was collected 3 times (spaced 10 min apart) at each session with the absorbent material placed in the lower conjunctival fornix until the 20-mm mark was reached (Schirmer strip, one eye) or for 1 min (PVA sponge, other eye). Tear extraction was performed with either centrifugation or elution in methanol. Doxycycline concentrations were measured with liquid chromatography-mass spectrometry. Low (100 ng/mL) and high (1,000 ng/mL) tear concentrations measured in vivo were spiked into each absorbent material in vitro to evaluate percentage drug recovery. After oral administration of doxycycline, the drug reached the tear compartment at concentrations of 45.1-900.7 ng/mL in cats and 45.4-632.0 ng/mL in dogs, representing a tear-to-serum ratio of 12% and 16%, respectively. Doxycycline tear concentrations were significantly more precise when tear collection was performed with Schirmer strips rather than PVA sponges (P = 0.007), but were not correlated with tear flow rate. In vitro doxycycline recovery was poor to moderate (<75%). Schirmer strips represent a good option for lacrimal doxycycline quantification, although the collection and subsequent extraction have to be optimized to improve drug recovery.

  2. Early Detection of Foot-And-Mouth Disease Virus from Infected Cattle Using A Dry Filter Air Sampling System.

    PubMed

    Pacheco, J M; Brito, B; Hartwig, E; Smoliga, G R; Perez, A; Arzt, J; Rodriguez, L L

    2017-04-01

    Foot-and-mouth disease (FMD) is a highly contagious livestock disease of high economic impact. Early detection of FMD virus (FMDV) is fundamental for rapid outbreak control. Air sampling collection has been demonstrated as a useful technique for detection of FMDV RNA in infected animals, related to the aerogenous nature of the virus. In the current study, air from rooms housing individual (n = 17) or two groups (n = 4) of cattle experimentally infected with FDMV A24 Cruzeiro of different virulence levels was sampled to assess the feasibility of applying air sampling as a non-invasive, screening tool to identify sources of FMDV infection. Detection of FMDV RNA in air was compared with first detection of clinical signs and FMDV RNA levels in serum and oral fluid. FMDV RNA was detected in room air samples 1-3 days prior (seven animals) or on the same day (four animals) as the appearance of clinical signs in 11 of 12 individually housed cattle. Only in one case clinical signs preceded detection in air samples by one day. Overall, viral RNA in oral fluid or serum preceded detection in air samples by 1-2 days. Six individually housed animals inoculated with attenuated strains did not show clinical signs, but virus was detected in air in one of these cases 3 days prior to first detection in oral fluid. In groups of four cattle housed together, air detection always preceded appearance of clinical signs by 1-2 days and coincided more often with viral shedding in oral fluid than virus in blood. These data confirm that air sampling is an effective non-invasive screening method for detecting FMDV infection in confined to enclosed spaces (e.g. auction barns, milking parlours). This technology could be a useful tool as part of a surveillance strategy during FMD prevention, control or eradication efforts. Published 2015. This article is a U.S. Government work and is in the public domain in the USA.

  3. Supercritical Fluid Extraction and Analysis of Tropospheric Aerosol Particles

    NASA Astrophysics Data System (ADS)

    Hansen, Kristen J.

    An integrated sampling and supercritical fluid extraction (SFE) cell has been designed for whole-sample analysis of organic compounds on tropospheric aerosol particles. The low-volume extraction cell has been interfaced with a sampling manifold for aerosol particle collection in the field. After sample collection, the entire SFE cell was coupled to a gas chromatograph; after on-line extraction, the cryogenically -focused sample was separated and the volatile compounds detected with either a mass spectrometer or a flame ionization detector. A 20-minute extraction at 450 atm and 90 ^circC with pure supercritical CO _2 is sufficient for quantitative extraction of most volatile compounds in aerosol particle samples. A comparison between SFE and thermal desorption, the traditional whole-sample technique for analyses of this type, was performed using ambient aerosol particle samples, as well as samples containing known amounts of standard analytes. The results of these studies indicate that SFE of atmospheric aerosol particles provides quantitative measurement of several classes of organic compounds. SFE provides information that is complementary to that gained by the thermal desorption analysis. The results also indicate that SFE with CO _2 can be validated as an alternative to thermal desorption for quantitative recovery of several organic compounds. In 1989, the organic constituents of atmospheric aerosol particles collected at Niwot Ridge, Colorado, along with various physical and meteorological data, were measured during a collaborative field study. Temporal changes in the composition of samples collected during summertime at the rural site were studied. Thermal desorption-GC/FID was used to quantify selected compounds in samples collected during the field study. The statistical analysis of the 1989 Niwot Ridge data set is presented in this work. Principal component analysis was performed on thirty-one variables selected from the data set in order to ascertain different source and process components, and to examine concentration changes in groups of variables with respect to time of day and meteorological conditions. Seven orthogonal groups of variables resulted from the statistical analysis; the groups serve as molecular markers for different biologic and anthropogenic emission sources. In addition, the results of the statistical analysis were used to investigate how several emission source contributions vary with respect to local atmospheric dynamics. Field studies were conducted in the urban environment in and around Boulder, CO. to characterize the dynamics, chemistry, and emission sources which affect the composition and concentration of different size-fractions of aerosol particles in the Boulder air mass. Relationships between different size fractions of particles and some gas-phase pollutants were elucidated. These field studies included an investigation of seasonal variations in the organic content and concentration of aerosol particles, and how these characteristics are related to local meteorology and to the concentration of some gas-phase pollutants. The elemental and organic composition of aerosol particles was investigated according to particle size in preliminary studies of size-differentiated samples of aerosol particles. In order to aid in future studies of urban aerosol particles, samples were collected at a forest fire near Boulder. Molecular markers specific to wood burning processes will be useful indicators of residential wood burning activities in future field studies.

  4. A multisystemic Acanthamoeba infection in a dog in Tenerife, Canary Islands, Spain.

    PubMed

    Valladares, María; Reyes-Batlle, María; Mora-Peces, Inmaculada; Martín-Navarro, Carmen M; López-Arencibia, Atteneri; Dorta-Gorrín, Alexis; Comyn-Afonso, Estefanía; Martínez-Carretero, Enrique; Maciver, Sutherland K; Piñero, José E; Valladares, Basilio; Lorenzo-Morales, Jacob

    2014-10-15

    A 22-month-old male Spanish water dog was hospitalized after its physical examination revealed fever and movement difficulty. After 24h, the dog was found to have a high fever (39.5 °C) and was treated empirically with doxycycline/ciprofloxacin. At 48 h, after submission the fever rose to 41 °C and the animal presented with a stiff neck and dehydration. Peripheral blood and cerebrospinal fluid (CSF) were sampled and trophozoites with an Acanthamoeba-like morphology were observed in the CSF. PCR specific for Acanthamoeba, Naegleria fowleri and Balamuthia mandrillaris were performed and the CSF sample found positive for Acanthamoeba. Lungs, kidney, liver and spleen samples were collected post mortem. All collected organ samples were positive for Acanthamoeba by PCR, thus confirming a multisystemic infection. Water samples taken at a suspected site of infection yielded an almost identical PCR fragment to those of the clinical samples, indicating that this was probably where the infection originated. This is the first report of a fatal case of Acanthamoeba disseminated infection in a dog in Spain. Copyright © 2014 Elsevier B.V. All rights reserved.

  5. STS-40 Exp. No. 192 urine monitoring system (UMS) on OV-102's middeck

    NASA Technical Reports Server (NTRS)

    1991-01-01

    STS-40 Experiment No. 192, Fluid-Electrolyte Regulation During Space Flight, urine monitoring system (UMS) is set up on the middeck of Columbia, Orbiter Vehicle (OV) 102, at the side hatch. The UMS is attached to OV-102's waste collection system (WCS). The urine specimen tray with sample tubes appears to the right of the UMS equipment.

  6. Exhaled breath condensate pH assays are not influenced by oral ammonia

    PubMed Central

    Wells, K; Vaughan, J; Pajewski, T; Hom, S; Ngamtrakulpanit, L; Smith, A; Nguyen, A; Turner, R; Hunt, J

    2005-01-01

    Background: Measurement of pH in exhaled breath condensate (EBC) is robust and simple. Acidic source fluid (airway lining fluid) traps bases while volatilising acids, leading to EBC acidification in many lung diseases. Lower airway ammonia is one determinant of airway lining fluid pH, raising the concern that addition of the base ammonia by contamination from the mouth might confound EBC pH assays. Methods: Three discrete methods were used to limit oral ammonia contamination of EBC collections: endotracheal intubation, oral rinsing, and –40°C condenser temperatures. Separately, ammonia was removed from collected EBC samples by lyophilisation and resuspension. Intraweek and intraday variability of ammonia concentration was determined in 76 subjects, and ammonia and pH from a further 235 samples were graphically compared. Ammonia was assayed spectrophotometrically and pH was assessed after deaeration. Results: Data from 1091 samples are presented. Ammonia was reduced in EBC by all methods. Endotracheal intubation decreased EBC ammonia from a mean (SD) of 619 (124) µM to 80 (24) µM (p<0.001, n = 32). Oral rinsing before collection also led to a decline in EBC ammonia from 573 (307) µM to 224 (80) µM (p = 0.016, n = 7). The colder the condensation temperature used, the less ammonia was trapped in the EBC. Lyophilisation removed 99.4 (1.9)% of ammonia. Most importantly, the pH of EBC never decreased after removal of ammonia by any of these methods. Intraweek and intraday coefficients of variation for ammonia were 64 (27)% and 60 (32)%, which is substantially more variable than EBC pH assays. Conclusions: Although ammonia and pH appear to correlate in EBC, the oral ammonia concentration is not an important determinant of EBC pH. No precautions need to be taken to exclude oral ammonia when EBC pH is of interest. The low pH and low ammonia found in EBC from patients with lung diseases appear to be independent effects of volatile compounds arising from the airway. PMID:15618579

  7. Impact of oral fluid collection device on cannabinoid stability following smoked cannabis.

    PubMed

    Anizan, Sébastien; Bergamaschi, Mateus M; Barnes, Allan J; Milman, Garry; Desrosiers, Nathalie; Lee, Dayong; Gorelick, David A; Huestis, Marilyn A

    2015-02-01

    Evaluation of cannabinoid stability in authentic oral fluid (OF) is critical, as most OF stability studies employed fortified or synthetic OF. Participants (n = 16) smoked a 6.8% delta-9-tetrahydrocannabinol (THC) cigarette, and baseline concentrations of THC, 11-nor-9-carboxy-THC (THCCOOH), cannabidiol (CBD), and cannabinol (CBN) were determined within 24 h in 16 separate pooled samples (collected 1 h before to 10.5 or 13 h after smoking). OF was collected with the StatSure Saliva Sampler™ and Oral-Eze® devices. Oral-Eze samples were re-analyzed after room temperature (RT) storage for 1 week, and for both devices after 4 °C for 1 and 4 weeks, and -20 °C for 4 and 24 weeks. Concentrations ±20% from initial concentrations were considered stable. With the StatSure device, all cannabinoids were within 80-120% median %baseline for all storage conditions. Individual THC, CBD, CBN and THCCOOH pool concentrations were stable in 100%, 100%, 80-94% and >85%, respectively, across storage conditions. With the Oral-Eze device, at RT or refrigerated storage (for 1 and 4 weeks), THC, CBD and THCCOOH were stable in 94-100%, 78-89%, and 93-100% of samples, respectively, while CBN concentrations were 53-79% stable. However, after 24 weeks at -20 °C, stability decreased, especially for CBD, with a median of 56% stability. Overall, the collection devices' elution/stabilizing buffers provided good stability for OF cannabinoids, with the exception of the more labile CBN. To ensure OF cannabinoid concentration accuracy, these data suggest analysis within 4 weeks at 4 °C storage for Oral-Eze collection and within 4 weeks at 4 °C or 24 weeks at -20 °C for StatSure collection. Published 2014. This article is a U.S. Government work and is in the public domain in the USA. Published 2014. This article is a U.S. Government work and is in the public domain in the USA.

  8. In vivo measurement of apolipoprotein E from the brain interstitial fluid using microdialysis

    PubMed Central

    2013-01-01

    Background The APOE4 allele variant is the strongest known genetic risk factor for developing late-onset Alzheimer’s disease. The link between apolipoprotein E (apoE) and Alzheimer’s disease is likely due in large part to the impact of apoE on the metabolism of amyloid β (Aβ) within the brain. Manipulation of apoE levels and lipidation within the brain has been proposed as a therapeutic target for the treatment of Alzheimer’s disease. However, we know little about the dynamic regulation of apoE levels and lipidation within the central nervous system. We have developed an assay to measure apoE levels in the brain interstitial fluid of awake and freely moving mice using large molecular weight cut-off microdialysis probes. Results We were able to recover apoE using microdialysis from human cerebrospinal fluid (CSF) in vitro and mouse brain parenchyma in vivo. Microdialysis probes were inserted into the hippocampus of wild-type mice and interstitial fluid was collected for 36 hours. Levels of apoE within the microdialysis samples were determined by ELISA. The levels of apoE were found to be relatively stable over 36 hours. No apoE was detected in microdialysis samples from apoE KO mice. Administration of the RXR agonist bexarotene increased ISF apoE levels while ISF Aβ levels were decreased. Extrapolation to zero-flow analysis allowed us to determine the absolute recoverable concentration of apoE3 in the brain ISF of apoE3 KI mice. Furthermore, analysis of microdialysis samples by non-denaturing gel electrophoresis determined lipidated apoE particles in microdialysis samples were consistent in size with apoE particles from CSF. Finally, we found that the concentration of apoE in the brain ISF was dependent upon apoE isoform in human apoE KI mice, following the pattern apoE2>apoE3>apoE4. Conclusions We are able to collect lipidated apoE from the brain of awake and freely moving mice and monitor apoE levels over the course of several hours from a single mouse. Our technique enables assessment of brain apoE dynamics under physiological and pathophysiological conditions and in response to therapeutic interventions designed to affect apoE levels and lipidation within the brain. PMID:23601557

  9. Decline of a Hydrothermal Vent Field - Escanaba Trough 12 Years Later

    NASA Astrophysics Data System (ADS)

    Zierenberg, R. A.; Clague, D. A.; Davis, A. S.; Lilley, M. D.; McClain, J. S.; Olson, E. S.; Ross, S. L.; Von Damm, K. L.

    2001-12-01

    Hydrothermal venting was discovered in Escanaba Trough, the southern sediment-covered portion of the Gorda Ridge, in 1988. Large pyrrhotite-rich massive sulfide mounds are abundant at each of the volcanic/intrusive centers that have been investigated in Escanaba Trough, but the only area of known hydrothermal venting is the NESCA site along the ridge axis at 41\\deg N. Hydrothermal fluids venting at 217\\deg C and 108\\deg C were sampled in 1988 on two sulfide mounds separated by about 275 m. The end-member fluid compositions were indistinguishable within analytical errors. Several sulfide mounds were observed in 1988 which had diffusely venting low temperature (< 20\\deg C) fluids that supported extensive vent communities dominated by fields of Ridgia. Nine holes were drilled in the NESCA area in 1996 on ODP Leg 169, including Hole 1036I that penetrated to basaltic basement at 405 m below sea floor (mbsf). Surveys of the area using the drill string camera located only one area of active venting at the same mound where 217\\deg C vent fluids were sampled from two active vents in 1988. Drill hole 1036A was spudded between the two active vents on this sulfide mound (approximately 4 and 8 m away) and penetrated to 115 mbsf. The NESCA site was revisited in 2000 using MBARI's R/V Western Flyer and ROV Tiburon. The hydrothermal vents appeared essentially identical to observations made from the drill string camera in 1996 despite the presence of a drill hole within meters of the two vents. The maximum vent temperature measured in 2000 was 212\\deg C. Fluid samples have major element and isotopic compositions very similar to those collected in 1988. The vent fluids have higher methane ( ~19 mmol/kg) than those from the geologically similar Middle Valley vent field, but lower values than those at Guaymas Basin. Drill hole 1036A was weakly venting, but the diffuse hydrothermal fluids could not be sampled with the equipment available. The walls of the drill hole were colonized by palm worms, limpets, and snails. Four other drill holes showed no hydrothermal flow nor visible evidence of down hole recharge. Mapping with Tiburon confirmed that the extent of hydrothermal venting at NESCA decreased dramatically since 1988. Formerly extensive colonies of Ridgia had vanished leaving no trace of their presence. Although hydrothermal venting has collapsed to a single mound, the temperature and composition of the fluids remained nearly unchanged. This is curious given that sediment pore fluids analyzed on Leg 169 included both high salinity and low salinity components of phase separated hydrothermal fluids in the shallow subsurface indicating that the hydrothermal field must have had a relatively recent (relative to the rate of pore fluid diffusion) high temperature history. Hydrothermal fluids presently venting at this site must be derived from an essentially homogeneous, approximately 215\\degC fluid reservoir that has declined in its fluid output on a decadal scale, but has not undergone significant changes in temperature and composition. Venting at the seafloor does not seem to have been affected by drilling in the hydrothermal field.

  10. Endoscopic ultrasound-guided transmural drainage of postoperative pancreatic collections.

    PubMed

    Tilara, Amy; Gerdes, Hans; Allen, Peter; Jarnagin, William; Kingham, Peter; Fong, Yuman; DeMatteo, Ronald; D'Angelica, Michael; Schattner, Mark

    2014-01-01

    Pancreatic leak is a major cause of morbidity after pancreatectomy. Traditionally, peripancreatic fluid collections have been managed by percutaneous or operative drainage. Data for endoscopic ultrasound (EUS)-guided drainage of postoperative fluid collections are limited. Here we report on the safety, efficacy, and timing of EUS-guided drainage of postoperative peripancreatic collections. This is a retrospective review of 31 patients who underwent EUS-guided drainage of fluid collections after pancreatic resection. Technical success was defined as successful transgastric deployment of at least one double pigtail plastic stent. Clinical success was defined as resolution of the fluid collection on follow-up CT scan and resolution of symptoms. Early drainage was defined as initial transmural stent placement within 30 days after surgery. Endoscopic ultrasound-guided drainage was performed effectively with a technical success rate of 100%. Clinical success was achieved in 29 of 31 patients (93%). Nineteen of the 29 patients (65%) had complete resolution of their symptoms and collection with the first endoscopic procedure. Repeat drainage procedures, including some with necrosectomy, were required in the remaining 10 patients, with eventual resolution of collection and symptoms. Two patients who did not achieve durable clinical success required percutaneous drainage by interventional radiology. Seventeen (55%) of 31 patients had successful early drainage completed within 30 days of their operation. Endoscopic ultrasound-guided drainage of fluid collections after pancreatic resection is safe and effective. Early drainage (<30 days) of postoperative pancreatic fluid collections was not associated with increased complications in this series. Copyright © 2014 American College of Surgeons. Published by Elsevier Inc. All rights reserved.

  11. Urine Sample Preparation in 96-Well Filter Plates for Quantitative Clinical Proteomics

    PubMed Central

    2015-01-01

    Urine is an important, noninvasively collected body fluid source for the diagnosis and prognosis of human diseases. Liquid chromatography mass spectrometry (LC-MS) based shotgun proteomics has evolved as a sensitive and informative technique to discover candidate disease biomarkers from urine specimens. Filter-aided sample preparation (FASP) generates peptide samples from protein mixtures of cell lysate or body fluid origin. Here, we describe a FASP method adapted to 96-well filter plates, named 96FASP. Soluble urine concentrates containing ∼10 μg of total protein were processed by 96FASP and LC-MS resulting in 700–900 protein identifications at a 1% false discovery rate (FDR). The experimental repeatability, as assessed by label-free quantification and Pearson correlation analysis for shared proteins among replicates, was high (R ≥ 0.97). Application to urinary pellet lysates which is of particular interest in the context of urinary tract infection analysis was also demonstrated. On average, 1700 proteins (±398) were identified in five experiments. In a pilot study using 96FASP for analysis of eight soluble urine samples, we demonstrated that protein profiles of technical replicates invariably clustered; the protein profiles for distinct urine donors were very different from each other. Robust, highly parallel methods to generate peptide mixtures from urine and other body fluids are critical to increase cost-effectiveness in clinical proteomics projects. This 96FASP method has potential to become a gold standard for high-throughput quantitative clinical proteomics. PMID:24797144

  12. Concentrations of tylvalosin and 3-O-acetyltylosin attained in the synovial fluid of swine after administration by oral gavage at 50 and 5 mg/kg.

    PubMed

    Canning, P; Bates, J; Hammen, K; Coetzee, J; Wulf, L; Rajewski, S; Wang, C; Karriker, L

    2016-12-01

    The objectives of this study were to determine the concentration of tylvalosin (TVN) and its metabolite, 3-O-acetyltylosin (3AT) in the synovial fluid of growing pigs when administered as a single bolus by oral gavage at target doses of 50 mg/kg (Trial 1) and 5 mg/kg (Trial 2). TVN is a water soluble macrolide antimicrobial used in swine production. The stability of the drug in synovial fluid samples stored at -70 °C up to 28 days was also evaluated in Trial 2. In Trial 1, eight pigs were randomly assigned to one of eight time points for euthanasia and synovial fluid collection: 0, 1, 2, 3, 4, 6, 9, 12 h postgavage. For Trial 2, 24 pigs were randomly allocated to one terminal collection time point at 0, 2, 4, 6, 8 or 10 h postgavage. Synovial fluid was analyzed to determine TVN and 3AT concentrations. TVN and 3AT were detected in Trial 1 at all time points, except 0 h. At 2 h postgavage for trial 2, the mean concentrations peaked at 31.17 ng/mL (95% CI: 18.62-52.16) for TVN and at 58.82 ng/mL (95% CI: 35.14-98.46) for 3AT. Storage duration did not impact TVN or 3AT concentrations (P-value 0.9732). © 2016 John Wiley & Sons Ltd.

  13. Biological monitoring of welders' exposure to chromium, molybdenum, tungsten and vanadium.

    PubMed

    Ellingsen, Dag G; Chashchin, Maxim; Berlinger, Balazs; Fedorov, Vladimir; Chashchin, Valery; Thomassen, Yngvar

    2017-05-01

    Welders are exposed to a number of metallic elements during work. Bioaccessability, that is important for element uptake, has been little studied. This study addresses bioaccessability and uptake of chromium (Cr), molybdenum (Mo), tungsten (W) and vanadium (V) among welders. Bioaccessability of Cr, Mo, V and W was studied in airborne particulate matter collected by personal sampling of the workroom air among shipyard welders by using the lung lining fluid simulant Hatch solution. Associations between concentrations of Hatch soluble and non-soluble elements (Hatch sol and Hatch non-sol ) and concentrations of the four elements in whole blood, serum, blood cells and urine were studied. Air concentrations of the four elements were low. Only a small fraction of Cr, V and W was Hatch sol , while similar amounts of Mo were Hatch sol and Hatch non-sol . Welders (N=70) had statistically significantly higher concentrations of all four elements in urine and serum when compared to referents (N=74). Highly statistically significant associations were observed between urinary W and Hatch sol W (p<0.001) and serum V and Hatch sol V (p<0.001), in particular when air samples collected the day before collection of biological samples were considered. Associations between Hatch sol elements in air and their biological concentrations were higher than when Hatch non-sol concentrations were considered. Associations were generally higher when air samples collected the day before biological sampling were considered as compared to air samples collected two days before. Copyright © 2017 Elsevier GmbH. All rights reserved.

  14. An evaluation of non-Luer safety connectors for neuraxial procedures.

    PubMed

    Sharpe, P; Scott, S; Gross, J M

    2013-06-01

    We evaluated seven non-Luer spinal needles in a two-part study. In part 1, we measured the time to see and collect simulated cerebrospinal fluid. In part 2, clinicians scored needle quality using a standardised questionnaire. The mean (SD) times to see cerebrospinal fluid varied in the lateral position from 4.2 (0.3) s (Vygon) to 25.2 (1.5) s (Sarstedt), and in the sitting position from 1.7 (0.2) s (BBraun) to 6.6 (0.3) s (Sarstedt). The time to collect cerebrospinal fluid varied from 43 (2.5) s (Vygon) to 139 (9.6) s (Pajunk) and from 19 (0.4) s (BBraun) to 34 (1.7) s (Pajunk), for the lateral and sitting positions, respectively. Median (IQR [range]) satisfaction scores in 205 needle function assessments were as follows: Sarstedt 9.0 (8.0-9.3 [5.0-10.0]); BD 8.0 (7.0-9.5 [3.0-10.0]); Pajunk 9.0 (8.0-9.8 [5.0-10.0]); Neurax 8.0 (7.0-9.0 [2.0-9.0]); Smiths 8.0 (7.0-9.0 [4.0-10.0]); Vygon 8.0 (7.5-9.0 [5.0-10.0]); and BBraun 9.0 (9.0-10.0 [7.0-10.0]). The difference in satisfaction scores between the BBraun and Neurax was significant (p < 0.01). A number of recurrent problems were found during the evaluation. The variation in time to collect cerebrospinal fluid samples may have implications for non-anaesthetic practice. This evaluation provides a baseline to assist others in commencing their procurement process. Anaesthesia © 2013 The Association of Anaesthetists of Great Britain and Ireland.

  15. Determination of the acid-base status in 50 horses admitted with colic between December 1998 and May 1999.

    PubMed Central

    Nappert, G; Johnson, P J

    2001-01-01

    The purpose of the present study was to investigate the acid-base status and the concentration of organic acids in horses with colic caused by various disorders. Blood samples were collected from 50 horses with colic and from 20 controls. No intravenous fluids had been given prior to sample collection. Identified causes of colic included gastric ulceration, small intestinal volvulus, cecal intussusception, cecal rupture, colonic impaction, left dorsal colon displacement, right dorsal colon displacement, colonic volvulus, colitis, peritonitis, and uterine torsion. Thirty-seven horses recovered from treatment of colic, 8 horses were euthanized, and 5 died. Most cases were not in severe metabolic acidosis. In previous studies, most horses presented for diagnosis and treatment of colic were in metabolic acidosis and in shock. PMID:11565369

  16. An efficient passive planar micromixer with ellipse-like micropillars for continuous mixing of human blood.

    PubMed

    Tran-Minh, Nhut; Dong, Tao; Karlsen, Frank

    2014-10-01

    In this paper, a passive planar micromixer with ellipse-like micropillars is proposed to operate in the laminar flow regime for high mixing efficiency. With a splitting and recombination (SAR) concept, the diffusion distance of the fluids in a micromixer with ellipse-like micropillars was decreased. Thus, space usage for micromixer of an automatic sample collection system is also minimized. Numerical simulation was conducted to evaluate the performance of proposed micromixer by solving the governing Navier-Stokes equation and convection-diffusion equation. With software (COMSOL 4.3) for computational fluid dynamics (CFD) we simulated the mixing of fluids in a micromixer with ellipse-like micropillars and basic T-type mixer in a laminar flow regime. The efficiency of the proposed micromixer is shown in numerical results and is verified by measurement results. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  17. Ultracentrifuge for separating fluid mixtures

    DOEpatents

    Lowry, Ralph A.

    1976-01-01

    1. A centrifuge for the separation of fluid mixtures having light and heavy fractions comprising a cylindrical rotor, disc type end-plugs closing the ends of the rotor, means for mounting said rotor for rotation about its cylindrical axis, a housing member enclosing the rotor, a vacuum chamber in said housing about the central portion of the rotor, a collection chamber at each end of the housing, the innermost side of which is substantially formed by the outer face of the end-plug, means for preventing flow of the fluid from the collection chambers to said vacuum chamber, at least one of said end-plugs having a plurality of holes therethrough communicating between the collection chamber adjacent thereto and the inside of the rotor to induce countercurrent flow of the fluid in the centrifuge, means for feeding fluid to be processed into the centrifuge, means communicating with the collection chambers to extract the light and heavy separated fractions of the fluid, and means for rotating the rotor.

  18. Shaft seal system

    DOEpatents

    Kapich, Davorin D.

    1985-01-01

    A shaft seal system is disclosed for isolating two regions of different fluid mediums through which a rotatable shaft extends. The seal system includes a seal housing through which the shaft extends and which defines an annular land and an annular labyrinth both of which face on the shaft so that each establishes a corresponding fluid sealing annulus. A collection cavity is formed in communication with the annular sealing spaces, and fluids compatible with the fluids in each of the two regions to be isolated are introduced, respectively, into the annular sealing spaces and collected in the collection cavity from which the fluid mixture is removed and passed to a separator which separates the fluids and returns them to their respective annular sealing spaces in a recycling manner. In the illustrated embodiment, the isolated fluid mediums comprise a liquid region and a gas region. Gas is removed from the gas region and passed through a purifier and a gas pump operative to introduce the purified gas through the labyrinth sealing annulus to the collection cavity. After passing to the separator, the separated gas is passed through a dryer from which the dried gas is caused to pass through the labyrinth sealing annulus into the collection cavity independently of the purified gas so as to insure isolation of the gas region in the event of sealing gas pump malfunction.

  19. An in situ Measurement of Extracellular Cysteamine, Homocysteine and Cysteine Concentrations in Organotypic Hippocampal Slice Cultures by Integration of Electroosmotic Sampling and Microfluidic Analysis

    PubMed Central

    Wu, Juanfang; Xu, Kerui; Landers, James P.; Weber, Stephen G.

    2013-01-01

    We demonstrate an all-electric sampling/derivatization/separation/detection system for the quantitation of thiols in tissue cultures. Extracellular fluid collected from rat organotypic hippocampal slice cultures (OHSCs) by electroosmotic flow through an11 cm (length) × 50 μm (ID) sampling capillary is introduced to a simple microfluidic chip for derivatization, continuous flow-gated injection, separation and detection.With the help of a fluorogenic, thiol-specific reagent, ThioGlo-1, we have successfully separated and detected the extracellular levels of free reduced cysteamine, homocysteineand cysteinefrom OHSCs within 25 s in a 23 mm separation channel with a confocal laser induced fluorescence (LIF) detector. Attention to the conductivities of the fluids being transported is required for successful flow-gated injections.When the sample conductivity is much higher than the run buffer conductivities, the electroosmotic velocities are such that there is less fluid coming by electroosmosis into the cross from the sample/reagent channel than is leaving by electroosmosis into the separation and waste channels. The resulting decrease in the internal fluid pressure in the injection cross pulls flow from the gated channel. This process may completely shut down the gated injection. Using a glycylglycine buffer with physiological osmolarity but only 62% of physiological conductivity and augmenting the conductivity of the run buffers solved this problem. Quantitation is by standard additions. Concentrations of cysteamine, homocysteine and cysteine in the extracellular space of OHSCs are10.6±1.0 nM (n=70), 0.18±0.01 μM (n=53) and 11.1±1.2 μM (n=70), respectively. This is the first in situquantitative estimation of endogenous cysteamine in brain. Extracellular levels of homocysteine and cysteine are comparable with other reported values. PMID:23330713

  20. Characterizing Microbial Community and Geochemical Dynamics at Hydrothermal Vents Using Osmotically Driven Continuous Fluid Samplers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Robidart, Julie C.; Callister, Stephen J.; Song, Peng F.

    2013-05-07

    Microbes play a key role in mediating all aquatic biogeochemical cycles, and ongoing efforts are aimed at better understanding the relationships between microbial phylogenetic and physiological diversity, and habitat physical and chemical characteristics. Establishing such relationships is facilitated by sampling and studying microbiology and geochemistry at the appropriate spatial and temporal scales, to access information on the past and current environmental state that contributes to observed microbial abundances and activities. A modest number of sampling systems exist to date, few of which can be used in remote, harsh environments such as hydrothermal vents, where the ephemeral nature of venting underscoresmore » the necessity for higher resolution sampling. We have developed a robust, continuous fluid sampling system for co-registered microbial and biogeochemical analyses. The osmosis-powered bio-osmosampling system (BOSS) use no electricity, collects fluids with daily resolution or better, can be deployed in harsh, inaccessible environments and can sample fluids continuously for up to five years. Here we present a series of tests to examine DNA, RNA and protein stability over time, as well as material compatability, via lab experiments. We also conducted two field deployments at deep-sea hydrothermal vents to assess changes in microbial diversity and protein expression as a function of the physico-chemical environment. Our data reveal significant changes in microbial community composition co-occurring with relatively modest changes in the geochemistry. These data additionally provide new insights into the distribution of an enigmatic sulfur oxidizing symbiont in its free-living state. Data from the second deployment reveal differences in the representation of peptides over time, underscoring the utility of the BOSS in meta-proteomic studies. In concert, these data demonstrate the efficacy of this approach, and illustrate the value of using this method to study microbial and geochemical phenomena.« less

  1. Peripancreatic collections in acute pancreatitis: Correlation between computerized tomography and operative findings

    PubMed Central

    Vege, Santhi Swaroop; Fletcher, Joel G; Talukdar, Rupjyoti; Sarr, Michael G

    2010-01-01

    AIM: To evaluate the ability of contrast-enhanced computerized tomography (CECT) to characterize the nature of peripancreatic collections. METHODS: Twenty five patients with peripancreatic collections on CECT and who underwent operative intervention for severe acute pancreatitis were retrospectively studied. The collections were classified into (1) necrosis without frank pus; (2) necrosis with pus; and (3) fluid without necrosis. A blinded radiologist assessed the preoperative CTs of each patient for necrosis and peripancreatic fluid collections. Peripancreatic collections were described in terms of volume, location, number, heterogeneity, fluid attenuation, wall perceptibility, wall enhancement, presence of extraluminal gas, and vascular compromise. RESULTS: Fifty-four collections were identified at operation, of which 45 (83%) were identified on CECT. Of these, 25/26 (96%) had necrosis without pus, 16/19 (84%) had necrosis with pus, and 4/9 (44%) had fluid without necrosis. Among the study characteristics, fluid heterogeneity was seen in a greater proportion of collections in the group with necrosis and pus, compared to the other two groups (94% vs 48% and 25%, P = 0.002 and 0.003, respectively). Among the wall characteristics, irregularity was seen in a greater proportion of collections in the groups with necrosis with and without pus, when compared to the group with fluid without necrosis (88% and 71% vs 25%, P = 0.06 and P < 0.01, respectively). The combination of heterogeneity and presence of extraluminal gas had a specificity and positive likelihood ratio of 92% and 5.9, respectively, in detecting pus. CONCLUSION: Most of the peripancreatic collections seen on CECT in patients with severe acute pancreatitis who require operative intervention contain necrotic tissue. CECT has a somewhat limited role in differentiating the different types of collections. PMID:20818812

  2. Guidelines for European workplace drug testing in oral fluid.

    PubMed

    Cooper, Gail; Moore, Christine; George, Claire; Pichini, Simona

    2011-05-01

    Over the past decade, oral fluid has established itself as a robust testing matrix for monitoring drug use or misuse. Commercially available collection devices provide opportunities to collect and test oral fluid by the roadside and near-patient testing with both clinical and criminal justice applications. One of the main advantages of oral fluid relates to the collection of the matrix which is non-invasive, simple, and can be carried out under direct observation making it ideal for workplace drug testing. Laboratories offering legally defensible oral fluid workplace drug testing must adhere to national and international quality standards (ISO/IEC 17025); however, these standards do not address issues specific to oral fluid testing. The European Workplace Drug Testing Society (EWDTS) recognizes the importance of providing best practice guidelines to organizations offering testing and those choosing to use oral fluid drug testing to test their employees. The aim of this paper is to present the EWDTS guidelines for oral fluid workplace drug testing. Copyright © 2011 John Wiley & Sons, Ltd.

  3. Quantitative liquid chromatographic determination of bromadoline and its N-demethylated metabolites in blood, plasma, serum, and urine samples.

    PubMed

    Peng, G W; Sood, V K; Rykert, U M

    1985-03-01

    Bromadoline and its two N-demethylated metabolites were extracted into ether:butyl chloride after the addition of internal standard and basification of the various biological fluids (blood, plasma, serum, and urine). These compounds were then extracted into dilute phosphoric acid from the organic phase and separated on a reversed-phase chromatographic system using a mobile phase containing acetonitrile and a buffer of 1,4-dimethylpiperazine and perchloric acid. The overall absolute extraction recoveries of these compounds were approximately 50-80%. The background interferences from the biological fluids were negligible and allowed quantitative determination of bromadoline and the metabolites at levels as low as 2-5 ng/mL. At mobile phase flow rate of 1 mL/min, the sample components and the internal standard were eluted at the retention times within approximately 7-12 min. The drug- and metabolite-to-internal standard peak height ratios showed excellent linear relationships with their corresponding concentrations. The analytical method showed satisfactory within- and between-run assay precision and accuracy, and has been utilized in the simultaneous determination of bromadoline and its two N-demethylated metabolites in biological fluids collected from humans and from dogs after administration of bromadoline maleate.

  4. A sample-freezing drive shoe for a wire line piston core sampler

    USGS Publications Warehouse

    Murphy, F.; Herkelrath, W.N.

    1996-01-01

    Loss of fluids and samples during retrieval of cores of saturated, noncohesive sediments results in incorrect measures of fluid distributions and an inaccurate measure of the stratigraphic position of the sample. To reduce these errors, we developed a hollow drive shoe that freezes in place the lowest 3 inches (75 mm) of a 1.88-inch-diameter (48 mm), 5-foot-long (1.5 m) sediment sample taken using a commercial wire line piston core sampler. The end of the core is frozen by piping liquid carbon dioxide at ambient temperature through a steel tube from a bottle at the land surface to the drive shoe where it evaporates and expands, cooling the interior surface of the shoe to about -109??F (-78??C). Freezing a core end takes about 10 minutes. The device was used to collect samples for a study of oil-water-air distributions, and for studies of water chemistry and microbial activity in unconsolidated sediments at the site of an oil spill near Bemidji, Minnesota. Before freezing was employed, samples of sandy sediments from near the water table sometimes flowed out of the core barrel as the sampler was withdrawn. Freezing the bottom of the core allowed for the retention of all material that entered the core barrel and lessened the redistribution of fluids within the core. The device is useful in the unsaturated and shallow saturated zones, but does not freeze cores well at depths greater than about 20 feet (6 m) below water, possibly because the feed tube plugs with dry ice with increased exhaust back-pressure, or because sediment enters the annulus between the core barrel and the core barrel liner and blocks the exhaust.

  5. Analysis of immune cells draining from the abdominal cavity as a novel tool to study intestinal transplant immunobiology.

    PubMed

    Meier, D; Cagnola, H; Ramisch, D; Rumbo, C; Chirdo, F; Docena, G; Gondolesi, G E; Rumbo, M

    2010-10-01

    During intestinal transplant (ITx) operation, intestinal lymphatics are not reconstituted. Consequently, trafficking immune cells drain freely into the abdominal cavity. Our aim was to evaluate whether leucocytes migrating from a transplanted intestine could be recovered from the abdominal draining fluid collected by a peritoneal drainage system in the early post-ITx period, and to determine potential applications of the assessment of draining cellular populations. The cell composition of the abdominal draining fluid was analysed during the first 11 post-ITx days. Using flow cytometry, immune cells from blood and draining fluid samples obtained the same day showed an almost complete lymphopenia in peripheral blood, whereas CD3(+) CD4(+) CD8(-) , CD3(+) CD4(-) CD8(+) and human leucocyte antigen D-related (HLA-DR)(+) CD19(+) lymphocytes were the main populations in the draining fluid. Non-complicated recipients evolved from a mixed leucocyte pattern including granulocytes, monocytes and lymphocytes to an exclusively lymphocytic pattern along the first post-ITx week. At days 1-2 post-Itx, analysis by short tandem repeats fingerprinting of CD3(+) CD8(+) sorted T cells from draining fluid indicated that 50% of cells were from graft origin, whereas by day 11 post-ITx this proportion decreased to fewer than 1%. Our results show for the first time that the abdominal drainage fluid contains mainly immune cells trafficking from the implanted intestine, providing the opportunity to sample lymphocytes draining from the grafted organ along the post-ITx period. Therefore, this analysis may provide information useful for understanding ITx immunobiology and eventually could also be of interest for clinical management. © 2010 The Authors. Clinical and Experimental Immunology © 2010 British Society for Immunology.

  6. Analysis of immune cells draining from the abdominal cavity as a novel tool to study intestinal transplant immunobiology

    PubMed Central

    Meier, D; Cagnola, H; Ramisch, D; Rumbo, C; Chirdo, F; Docena, G; Gondolesi, G E; Rumbo, M

    2010-01-01

    During intestinal transplant (ITx) operation, intestinal lymphatics are not reconstituted. Consequently, trafficking immune cells drain freely into the abdominal cavity. Our aim was to evaluate whether leucocytes migrating from a transplanted intestine could be recovered from the abdominal draining fluid collected by a peritoneal drainage system in the early post-ITx period, and to determine potential applications of the assessment of draining cellular populations. The cell composition of the abdominal draining fluid was analysed during the first 11 post-ITx days. Using flow cytometry, immune cells from blood and draining fluid samples obtained the same day showed an almost complete lymphopenia in peripheral blood, whereas CD3+CD4+CD8-, CD3+CD4-CD8+ and human leucocyte antigen D-related (HLA-DR)+CD19+ lymphocytes were the main populations in the draining fluid. Non-complicated recipients evolved from a mixed leucocyte pattern including granulocytes, monocytes and lymphocytes to an exclusively lymphocytic pattern along the first post-ITx week. At days 1–2 post-Itx, analysis by short tandem repeats fingerprinting of CD3+CD8+ sorted T cells from draining fluid indicated that 50% of cells were from graft origin, whereas by day 11 post-ITx this proportion decreased to fewer than 1%. Our results show for the first time that the abdominal drainage fluid contains mainly immune cells trafficking from the implanted intestine, providing the opportunity to sample lymphocytes draining from the grafted organ along the post-ITx period. Therefore, this analysis may provide information useful for understanding ITx immunobiology and eventually could also be of interest for clinical management. PMID:20831713

  7. Simultaneous screening and quantification of 29 drugs of abuse in oral fluid by solid-phase extraction and ultraperformance LC-MS/MS.

    PubMed

    Badawi, Nora; Simonsen, Kirsten Wiese; Steentoft, Anni; Bernhoft, Inger Marie; Linnet, Kristian

    2009-11-01

    The European DRUID (Driving under the Influence of Drugs, Alcohol And Medicines) project calls for analysis of oral fluid (OF) samples, collected randomly and anonymously at the roadside from drivers in Denmark throughout 2008-2009. To analyze these samples we developed an ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method for detection of 29 drugs and illicit compounds in OF. The drugs detected were opioids, amphetamines, cocaine, benzodiazepines, and Delta-9-tetrahydrocannabinol. Solid-phase extraction was performed with a Gilson ASPEC XL4 system equipped with Bond Elut Certify sample cartridges. OF samples (200 mg) diluted with 5 mL of ammonium acetate/methanol (vol/vol 90:10) buffer were applied to the columns and eluted with 3 mL of acetonitrile with aqueous ammonium hydroxide. Target drugs were quantified by use of a Waters ACQUITY UPLC system coupled to a Waters Quattro Premier XE triple quadrupole (positive electrospray ionization mode, multiple reaction monitoring mode). Extraction recoveries were 36%-114% for all analytes, including Delta-9-tetrahydrocannabinol and benzoylecgonine. The lower limit of quantification was 0.5 mug/kg for all analytes. Total imprecision (CV) was 5.9%-19.4%. With the use of deuterated internal standards for most compounds, the performance of the method was not influenced by matrix effects. A preliminary account of OF samples collected at the roadside showed the presence of amphetamine, cocaine, codeine, Delta-9-tetrahydrocannabinol, tramadol, and zopiclone. The UPLC-MS/MS method makes it possible to detect all 29 analytes in 1 chromatographic run (15 min), including Delta-9-tetrahydrocannabinol and benzoylecgonine, which previously have been difficult to incorporate into multicomponent methods.

  8. Fluid permeability measurement system and method

    DOEpatents

    Hallman, Jr., Russell Louis; Renner, Michael John [Oak Ridge, TN

    2008-02-05

    A system for measuring the permeance of a material. The permeability of the material may also be derived. The system provides a liquid or high concentration fluid bath on one side of a material test sample, and a gas flow across the opposing side of the material test sample. The mass flow rate of permeated fluid as a fraction of the combined mass flow rate of gas and permeated fluid is used to calculate the permeance of the material. The material test sample may be a sheet, a tube, or a solid shape. Operational test conditions may be varied, including concentration of the fluid, temperature of the fluid, strain profile of the material test sample, and differential pressure across the material test sample.

  9. Microbiota in Exhaled Breath Condensate and the Lung.

    PubMed

    Glendinning, Laura; Wright, Steven; Tennant, Peter; Gill, Andrew C; Collie, David; McLachlan, Gerry

    2017-06-15

    The lung microbiota is commonly sampled using relatively invasive bronchoscopic procedures. Exhaled breath condensate (EBC) collection potentially offers a less invasive alternative for lung microbiota sampling. We compared lung microbiota samples retrieved by protected specimen brushings (PSB) and exhaled breath condensate collection. We also sought to assess whether aerosolized antibiotic treatment would influence the lung microbiota and whether this change could be detected in EBC. EBC was collected from 6 conscious sheep and then from the same anesthetized sheep during mechanical ventilation. Following the latter EBC collection, PSB samples were collected from separate sites within each sheep lung. On the subsequent day, each sheep was then treated with nebulized colistimethate sodium. Two days after nebulization, EBC and PSB samples were again collected. Bacterial DNA was quantified using 16S rRNA gene quantitative PCR. The V2-V3 region of the 16S rRNA gene was amplified by PCR and sequenced using Illumina MiSeq. Quality control and operational taxonomic unit (OTU) clustering were performed with mothur. The EBC samples contained significantly less bacterial DNA than the PSB samples. The EBC samples from anesthetized animals clustered separately by their bacterial community compositions in comparison to the PSB samples, and 37 bacterial OTUs were identified as differentially abundant between the two sample types. Despite only low concentrations of colistin being detected in bronchoalveolar lavage fluid, PSB samples were found to differ by their bacterial compositions before and after colistimethate sodium treatment. Our findings indicate that microbiota in EBC samples and PSB samples are not equivalent. IMPORTANCE Sampling of the lung microbiota usually necessitates performing bronchoscopic procedures that involve a hospital visit for human participants and the use of trained staff. The inconvenience and perceived discomfort of participating in this kind of research may deter healthy volunteers and may not be a safe option for patients with advanced lung disease. This study set out to evaluate a less invasive method for collecting lung microbiota samples by comparing samples taken via protected specimen brushings (PSB) to those taken via exhaled breath condensate (EBC) collection. We found that there was less bacterial DNA in EBC samples compared with that in PSB samples and that there were differences between the bacterial communities in the two sample types. We conclude that while EBC and PSB samples do not produce equivalent microbiota samples, the study of the EBC microbiota may still be of interest. Copyright © 2017 Glendinning et al.

  10. Exhaled Breath Condensate Collection in the Mechanically Ventilated Patient

    PubMed Central

    Carter, Stewart R; Davis, Christopher S; Kovacs, Elizabeth J

    2012-01-01

    Collection of exhaled breath condensate (EBC) is a non-invasive means of sampling the airway-lining fluid of the lungs. EBC contains numerous measurable mediators, whose analysis could change the management of patients with certain pulmonary diseases. While initially popularized in investigations involving spontaneously breathing patients, an increasing number of studies have been performed using EBC in association with mechanical ventilation. Collection of EBC in mechanically ventilated patients follows basic principles of condensation, but is influenced by multiple factors. Effective collection requires selection of a collection device, adequate minute ventilation, low cooling temperatures, and sampling times of greater than ten minutes. Condensate can be contaminated by saliva, which needs to be filtered. Dilution of samples occurs secondary to distilled water in vapors and humidification in the ventilator circuit. Dilution factors may need to be employed when investigating non-volatile biomarkers. Storage and analysis should occur promptly at −70° C to −80° C to prevent rapid degradation of samples. The purpose of this review is to examine and describe methodologies and problems of EBC collection in mechanically ventilated patients. A straightforward and safe framework has been established to investigate disease processes in this population, yet technical aspects of EBC collection still exist that prevent clinical practicality of this technology. These include a lack of standardization of procedure and analysis of biomarkers, and of normal reference ranges for mediators in healthy individuals. Once these procedural aspects have been addressed, EBC could serve as a non-invasive alternative to invasive evaluation of lungs in mechanically ventilated patients. PMID:22398157

  11. Digital Curation of Marine Physical Samples at Ocean Networks Canada

    NASA Astrophysics Data System (ADS)

    Jenkyns, R.; Tomlin, M. C.; Timmerman, R.

    2015-12-01

    Ocean Networks Canada (ONC) has collected hundreds of geological, biological and fluid samples from the water column and seafloor during its maintenance expeditions. These samples have been collected by Remotely Operated Vehicles (ROVs), divers, networked and autonomously deployed instruments, and rosettes. Subsequent measurements are used for scientific experiments, calibration of in-situ and remote sensors, monitoring of Marine Protected Areas, and environment characterization. Tracking the life cycles of these samples from collection to dissemination of results with all the pertinent documents (e.g., protocols, imagery, reports), metadata (e.g., location, identifiers, purpose, method) and data (e.g., measurements, taxonomic classification) is a challenge. The initial collection of samples is normally documented in SeaScribe (an ROV dive logging tool within ONC's Oceans 2.0 software) for which ONC has defined semantics and syntax. Next, samples are often sent to individual scientists and institutions (e.g., Royal BC Museum) for processing and storage, making acquisition of results and life cycle metadata difficult. Finally, this information needs to be retrieved and collated such that multiple user scenarios can be addressed. ONC aims to improve and extend its digital infrastructure for physical samples to support this complex array of samples, workflows and applications. However, in order to promote effective data discovery and exchange, interoperability and community standards must be an integral part of the design. Thus, integrating recommendations and outcomes of initiatives like the EarthCube iSamples working groups are essential. Use cases, existing tools, schemas and identifiers are reviewed, while remaining gaps and challenges are identified. The current status, selected approaches and possible future directions to enhance ONC's digital infrastructure for each sample type are presented.

  12. Swab2know: An HIV-Testing Strategy Using Oral Fluid Samples and Online Communication of Test Results for Men Who Have Sex With Men in Belgium.

    PubMed

    Platteau, Tom; Fransen, Katrien; Apers, Ludwig; Kenyon, Chris; Albers, Laura; Vermoesen, Tine; Loos, Jasna; Florence, Eric

    2015-09-01

    As HIV remains a public health concern, increased testing among those at risk for HIV acquisition is important. Men who have sex with men (MSM) are the most important group for targeted HIV testing in Europe. Several new strategies have been developed and implemented to increase HIV-testing uptake in this group, among them the Swab2know project. In this project, we aim to assess the acceptability and feasibility of outreach and online HIV testing using oral fluid samples as well as Web-based delivery of test results. Sample collection happened between December 2012 and April 2014 via outreach and online sampling among MSM. Test results were communicated through a secured website. HIV tests were executed in the laboratory. Each reactive sample needed to be confirmed using state-of-the-art confirmation procedures on a blood sample. Close follow-up of participants who did not pick up their results, and those with reactive results, was included in the protocol. Participants were asked to provide feedback on the methodology using a short survey. During 17 months, 1071 tests were conducted on samples collected from 898 men. Over half of the samples (553/1071, 51.63%) were collected during 23 outreach sessions. During an 8-month period, 430 samples out of 1071 (40.15%) were collected from online sampling. Additionally, 88 samples out of 1071 (8.22%) were collected by two partner organizations during face-to-face consultations with MSM and male sex workers. Results of 983 out of 1071 tests (91.78%) had been collected from the website. The pickup rate was higher among participants who ordered their kit online (421/430, 97.9%) compared to those participating during outreach activities (559/641, 87.2%; P<.001). MSM participating during outreach activities versus online participants were more likely to have never been tested before (17.3% vs 10.0%; P=.001) and reported more sexual partners in the 6 months prior to participation in the project (mean 7.18 vs 3.23; P<.001). A total of 20 participants out of 898 (2.2%) were confirmed HIV positive and were linked to care. Out of 1071 tests, 28 (2.61%) with a weak reactive result could not be confirmed, and were thereby classified as false reactive results. Most of the 388 participants who completed posttest surveys (388/983, 39.5%) were very positive about their experience. The vast majority (371/388, 95.6%) were very satisfied, while 17 out of 388 (4.4%) reported mixed feelings. Despite a high yield and a considerable number of false reactive results, satisfaction was high among participants. The project helped us to reach the target population, both in numbers of tests executed and in newly diagnosed HIV infections. Further optimization should be considered in the accuracy of the test, the functionalities of the website (including an online counseling tool), and in studying the cost effectiveness of the methodology.

  13. Alpha-2-Macroglobulin Levels in Gingival Crevicular Fluid Pre- and Post-scaling and Root Planing with Adjunctive Tetracycline Fibers in Chronic Periodontitis: A Randomized Controlled Trial.

    PubMed

    Chhina, Shivjot; Rathore, Ajit Singh; Juneja, Saurabh

    2015-06-01

    This split-mouth clinical study aimed to investigate levels of alpha-2-macroglobulin (a2M) in gingival crevicular fluid (GCF) of chronic periodontitis patients pre- and post-scaling and root planing (SRP) with or without adjunctive use of tetracycline fibers. In 30 patients of chronic periodontitis, samples of GCF were collected from the gingival sulcus before SRP. Recording of clinical parameters was conducted. This was followed by local drug delivery (LDD) of tetracycline fibers in test sites. In control sites, no LDD was done. Second samples of GCF were taken 90 days after treatment. Samples of crevicular fluid were analyzed to determine the levels of a2m. A gain of clinical attachment (CAL) of 3.30 mm for SRP and LDD and for SRP alone was 1.62 mm (p < 0.001). The pocket probing depth was significantly decreased by 2.43 mm for SRP and LDD and for SRP alone was 1.61 mm (p < 0.001) after 90 days. Alpha-2-macroglobulin was significantly reduced in GCF by SRP and SRP and LDD after 90 days (p < 0.001). Clinical and biochemical variables showed a more favorable outcome when SRP was combined with LDD of tetracycline fibers in management of patients suffering from chronic periodontitis.

  14. Chemical Degradation of Polyacrylamide during Hydraulic Fracturing

    NASA Astrophysics Data System (ADS)

    Xiong, B.; Tasker, T.; Miller, Z.; Roman-White, S.; Farina, B.; Piechowicz, B.; Burgos, W.; Joshi, P.; Zhu, L.; Gorski, C.; Zydney, A.; Kumar, M.

    2017-12-01

    Polyacrylamide (PAM) based friction reducers are a primary ingredient of slickwater hydraulic fracturing fluids. Little is known regarding the fate of these polymers under downhole conditions, which could have important environmental impacts including strategies for reuse or treatment of flowback water. The objective of this study was to evaluate the chemical degradation of high molecular weight PAM, including the effects of shale, oxygen, temperature, pressure, and salinity. Data were obtained with a slickwater fracturing fluid exposed to both a shale sample collected from a Marcellus shale outcrop and to Marcellus core samples at high pressures/temperatures (HPT) simulating downhole conditions. Based on size exclusion chromatography analyses, the peak molecular weight of the PAM was reduced by two orders of magnitude, from roughly 10 MDa to 200 kDa under typical HPT fracturing conditions. The rate of degradation was independent of pressure and salinity but increased significantly at high temperatures and in the presence of oxygen dissolved in fracturing fluid. Results were consistent with a free radical chain scission mechanism, supported by measurements of sub-M hydroxyl radical concentrations. The shale sample adsorbed some PAM ( 30%), but importantly it catalyzed the chemical degradation of PAM, likely due to dissolution of Fe2+ at low pH. These results provide the first evidence of radical-induced degradation of PAM under HPT hydraulic fracturing conditions without additional oxidative breaker.

  15. Chemical Degradation of Polyacrylamide during Hydraulic Fracturing.

    PubMed

    Xiong, Boya; Miller, Zachary; Roman-White, Selina; Tasker, Travis; Farina, Benjamin; Piechowicz, Bethany; Burgos, William D; Joshi, Prachi; Zhu, Liang; Gorski, Christopher A; Zydney, Andrew L; Kumar, Manish

    2018-01-02

    Polyacrylamide (PAM) based friction reducers are a primary ingredient of slickwater hydraulic fracturing fluids. Little is known regarding the fate of these polymers under downhole conditions, which could have important environmental impacts including decisions on strategies for reuse or treatment of flowback water. The objective of this study was to evaluate the chemical degradation of high molecular weight PAM, including the effects of shale, oxygen, temperature, pressure, and salinity. Data were obtained with a slickwater fracturing fluid exposed to both a shale sample collected from a Marcellus outcrop and to Marcellus core samples at high pressures/temperatures (HPT) simulating downhole conditions. Based on size exclusion chromatography analyses, the peak molecular weight of the PAM was reduced by 2 orders of magnitude, from roughly 10 MDa to 200 kDa under typical HPT fracturing conditions. The rate of degradation was independent of pressure and salinity but increased significantly at high temperatures and in the presence of oxygen dissolved in fracturing fluids. Results were consistent with a free radical chain scission mechanism, supported by measurements of sub-μM hydroxyl radical concentrations. The shale sample adsorbed some PAM (∼30%), but importantly it catalyzed the chemical degradation of PAM, likely due to dissolution of Fe 2+ at low pH. These results provide the first evidence of radical-induced degradation of PAM under HPT hydraulic fracturing conditions without additional oxidative breaker.

  16. Quantitative measurement of XLR11 and UR-144 in oral fluid by LC-MS-MS.

    PubMed

    Amaratunga, Piyadarsha; Thomas, Christopher; Lemberg, Bridget Lorenz; Lemberg, Dave

    2014-01-01

    Availability and consumption of synthetic cannabinoids have risen recently in the USA and Europe. These drugs have adverse effects, including acute psychosis and bizarre behavior. In 2012, the United States Drug Enforcement Agency permanently banned five of the synthetic cannabinoids and in 2013, temporarily added XLR11, UR-144 and AKB48 to Schedule I of the Controlled Substances Act. As synthetic cannabinoid strains are added to the Schedule I list, new strains are being introduced into the market. XLR11 and UR-144 are two of the most recent additions to the synthetic cannabinoid drug class. To test collected oral fluid samples for XLR11 and UR-144, we developed a bioanalytical method that initially purifies the sample with solid-phase extraction and then quantitatively identifies the drugs with ultra-high-performance liquid chromatography-tandem mass spectrometry. The method was validated according to United States Food and Drug Administration guidelines and Scientific Working Group for Forensic Toxicology guidelines and the validation data showed that the method is an accurate, precise, robust and efficient method suited for high-throughput toxicological screening applications. We tested human subject samples with the developed method and found the presence of parent drugs (XLR11 and UR-144), their metabolites and their pyrolysis products in oral fluid. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  17. Trace elements levels in the serum, urine, and semen of patients with infertility.

    PubMed

    Sağlam, Hasan Salih; Altundağ, Hüseyin; Atik, Yavuz Tarık; Dündar, Mustafa Şahin; Adsan, Öztug

    2015-01-01

    Studies suggest that trace elements may have an adverse impact on male reproduction, even at low levels. We tried to investigate the relationships between these metals and semen quality in various body fluids among men with infertility. A total of 255 samples of blood, semen, and urine were collected from 85 men suffering from infertility. Inductively coupled plasma-optical emission spectrometry was used for the determination of 22 trace elements. We compared the results of the semen parameters with the results of the element determinations. Because of the high proportion of samples with values lower than the limit of detection for a number of the elements, only 8 of a total 22 trace elements were determined in the samples. When the concentrations of sperm were classified according to the World Health Organization's guidelines for normospermia, oligospermia, and azoospermia, statistically significant differences were found among Zn, Ca, Al, Cu, Mg, Se, and Sr concentrations in various serum, sperm, and urine samples (P < 0.05). In the present study, we found significant correlations between concentrations of Zn, Ca, Al, Cu, Mg, Se, and Sr and semen parameters in various body fluids.

  18. Microfluidic separation of motile sperm with millilitre-scale sample capacity

    NASA Astrophysics Data System (ADS)

    Nosrati, Reza; Vollmer, Marion; Eamer, Lise; Zeidan, Krista; San Gabriel, Maria C.; Zini, Armand; Sinton, David

    2012-11-01

    Isolating motile from non-motile spermatozoa has been a challenge since the establishment of in vitro fertilization. Microfluidic approaches have been employed for this purpose, but current devices are limited by low sample volume. Here, we present a high-throughput microfluidic device that separates spermatozoa from one millilitre of raw semen sample based on the hydrodynamic characteristics of swimming sperm in a confined geometry. The device consists of two layers: an outer injection ring on top aligned with a network of radial microchannels at the bottom guiding motile sperm into an inner collection chamber. This approach (1) maximizes exposure of the sperm to the fluid channels, (2) maximizes surface area density (3) prevents fluid flow bias, and (4) employs a non-Newtonian viscoelastic medium consistent with the in vivo environment. Tests with human and bull spermatozoa indicate an increase in motile sperm concentration from 62.2% in raw semen to 99.2% in separated sample combined with a higher incidence of normal morphology. DNA integrity testing is currently underway. In conclusion, we present an effective one-step procedure to perform semen purification and separation on a millilitre-scale with clinically relevant numbers.

  19. On sweat analysis for quantitative estimation of dehydration during physical exercise.

    PubMed

    Ring, Matthias; Lohmueller, Clemens; Rauh, Manfred; Eskofier, Bjoern M

    2015-08-01

    Quantitative estimation of water loss during physical exercise is of importance because dehydration can impair both muscular strength and aerobic endurance. A physiological indicator for deficit of total body water (TBW) might be the concentration of electrolytes in sweat. It has been shown that concentrations differ after physical exercise depending on whether water loss was replaced by fluid intake or not. However, to the best of our knowledge, this fact has not been examined for its potential to quantitatively estimate TBW loss. Therefore, we conducted a study in which sweat samples were collected continuously during two hours of physical exercise without fluid intake. A statistical analysis of these sweat samples revealed significant correlations between chloride concentration in sweat and TBW loss (r = 0.41, p <; 0.01), and between sweat osmolality and TBW loss (r = 0.43, p <; 0.01). A quantitative estimation of TBW loss resulted in a mean absolute error of 0.49 l per estimation. Although the precision has to be improved for practical applications, the present results suggest that TBW loss estimation could be realizable using sweat samples.

  20. Neuropeptide Kyotorphin (Tyrosyl-Arginine) has Decreased Levels in the Cerebro-Spinal Fluid of Alzheimer's Disease Patients: Potential Diagnostic and Pharmacological Implications.

    PubMed

    Santos, Sara Matos; Garcia-Nimo, Laura; Sá Santos, Sónia; Tavares, Isaura; Cocho, José A; Castanho, Miguel A R B

    2013-01-01

    In Alzheimer's disease (AD), besides the characteristic deterioration of memory, studies also point to a higher pain tolerance in spite of sensibility preservation. A change in the normal tau protein phosphorylation is also characteristic of AD, which contributes to the pathogenesis of the disease and is useful in early diagnosis. Kyotorphin (KTP) is an endogenous analgesic dipeptide (Tyr-Arg) for which there is evidence of eventual neuroprotective and neuromodulatory properties. The objective of this work was to study the possible correlation between KTP and phosphorylated tau protein (p-tau) levels in cerebro-spinal fluid (CSF) samples of AD patients. CSF samples were collected from 25 AD patients and 13 age-matched controls (N), where p-tau and KTP levels were measured. We found a statistically significant difference between p-tau/KTP values in AD and N groups with an inverse correlation between p-tau and KTP values in AD samples. These results suggest that in the future KTP may be a candidate biomarker for neurodegeneration and may be a lead compound to be used pharmacologically for neuroprotection.

  1. Identification of Streptococcus pneumoniae lytA, plyA and psaA genes in pleural fluid by multiplex real-time PCR.

    PubMed

    Sanz, Juan Carlos; Ríos, Esther; Rodríguez-Avial, Iciar; Ramos, Belén; Marín, Mercedes; Cercenado, Emilia

    2017-08-14

    The aim was to evaluate the utility of a multiplex real-time PCR to detect Streptococcus pneumoniae lytA, plyA and psaA genes in pleural fluid (PF). A collection of 81 PF samples was used. Sixty were considered positive for S. pneumoniae according to previous results (54 by an in-house lytA gene PCR and eight by universal rRNA PCR). The sensitivity for detection of the lytA, plyA and psaA genes by multiplex PCR was 100% (60/60), 98.3% (59/60) and 91.7% (55/60), respectively. The detection of all three genes was negative in 21 samples formerly confirmed as negative for S. pneumoniae (100% specificity) by the other procedures (9 by in-house lytA PCR and 12 by rRNA PCR). The use of this multiplex PCR may be a useful option to identify S. pneumoniae directly in PF samples. Copyright © 2017 Elsevier España, S.L.U. and Sociedad Española de Enfermedades Infecciosas y Microbiología Clínica. All rights reserved.

  2. Strontium isotope constraints on fluid flow in the sheeted dike complex of fast spreading crust: Pervasive fluid flow at Pito Deep

    NASA Astrophysics Data System (ADS)

    Barker, A. K.; Coogan, L. A.; Gillis, K. M.; Weis, D.

    2008-06-01

    Fluid flow through the axial hydrothermal system at fast spreading ridges is investigated using the Sr-isotopic composition of upper crustal samples recovered from a tectonic window at Pito Deep (NE Easter microplate). Samples from the sheeted dike complex collected away from macroscopic evidence of channelized fluid flow, such as faults and centimeter-scale hydrothermal veins, show a range of 87Sr/86Sr from 0.7025 to 0.7030 averaging 0.70276 relative to a protolith with 87Sr/86Sr of ˜0.7024. There is no systematic variation in 87Sr/86Sr with depth in the sheeted dike complex. Comparison of these new data with the two other localities that similar data sets exist for (ODP Hole 504B and the Hess Deep tectonic window) reveals that the extent of Sr-isotope exchange is similar in all of these locations. Models that assume that fluid-rock reaction occurs during one-dimensional (recharge) flow lead to significant decreases in the predicted extent of isotopic modification of the rock with depth in the crust. These model results show systematic misfits when compared with the data that can only be avoided if the fluid flow is assumed to be focused in isolated channels with very slow fluid-rock exchange. In this scenario the fluid at the base of the crust is little modified in 87Sr/86Sr from seawater and thus unlike vent fluids. Additionally, this model predicts that some rocks should show no change from the fresh-rock 87Sr/86Sr, but this is not observed. Alternatively, models in which fluid-rock reaction occurs during upflow (discharge) as well as downflow, or in which fluids are recirculated within the hydrothermal system, can reproduce the observed lack of variation in 87Sr/86Sr with depth in the crust. Minimum time-integrated fluid fluxes, calculated from mass balance, are between 1.5 and 2.6 × 106 kg m-2 for all areas studied to date. However, new evidence from both the rocks and a compilation of vent fluid compositions demonstrates that some Sr is leached from the crust. Because this leaching lowers the fluid 87Sr/86Sr without changing the rock 87Sr/86Sr, these mass balance models must underestimate the time-integrated fluid flux. Additionally, these values do not account for fluid flow that is channelized within the crust.

  3. Reduction of hexavalent chromium by fasted and fed human gastric fluid. II. Ex vivo gastric reduction modeling

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kirman, Christopher R., E-mail: ckirman@summittoxi

    To extend previous models of hexavalent chromium [Cr(VI)] reduction by gastric fluid (GF), ex vivo experiments were conducted to address data gaps and limitations identified with respect to (1) GF dilution in the model; (2) reduction of Cr(VI) in fed human GF samples; (3) the number of Cr(VI) reduction pools present in human GF under fed, fasted, and proton pump inhibitor (PPI)-use conditions; and (4) an appropriate form for the pH-dependence of Cr(VI) reduction rate constants. Rates and capacities of Cr(VI) reduction were characterized in gastric contents from fed and fasted volunteers, and from fasted pre-operative patients treated with PPIs.more » Reduction capacities were first estimated over a 4-h reduction period. Once reduction capacity was established, a dual-spike approach was used in speciated isotope dilution mass spectrometry analyses to characterize the concentration-dependence of the 2nd order reduction rate constants. These data, when combined with previously collected data, were well described by a three-pool model (pool 1 = fast reaction with low capacity; pool 2 = slow reaction with higher capacity; pool 3 = very slow reaction with higher capacity) using pH-dependent rate constants characterized by a piecewise, log-linear relationship. These data indicate that human gastric samples, like those collected from rats and mice, contain multiple pools of reducing agents, and low concentrations of Cr(VI) (< 0.7 mg/L) are reduced more rapidly than high concentrations. The data and revised modeling results herein provide improved characterization of Cr(VI) gastric reduction kinetics, critical for Cr(VI) pharmacokinetic modeling and human health risk assessment. - Highlights: • SIDMS allows for measurement of Cr(VI) reduction rate in gastric fluid ex vivo • Human gastric fluid has three reducing pools • Cr(VI) in drinking water at < 0.7 mg/L is rapidly reduced in human gastric fluid • Reduction rate is concentration- and pH-dependent • A refined PK model is used to characterize inter-individual variability in Cr(VI) gastric reduction capacity.« less

  4. The role of fluid mobility in the development of shale weathering profiles: Direct observations from a vadose zone monitoring system

    NASA Astrophysics Data System (ADS)

    Druhan, J. L.; Wang, J.; Cargill, S.; Murphy, C.; Tune, A. K.; Dietrich, W. E.; Rempe, D.

    2017-12-01

    Extensive effort has focused on resolving the contribution of weathering reactions to the transfer of mass over scales ranging from individual hillslope weathering profiles, across local watersheds, to continental drainage networks. A persistent limitation in quantifying these fluxes is the variability in fluid flowpaths through the subsurface, which may alter the extent of chemical weathering relative to that expected from idealized homogenous conditions. In the past decade, the consequence of fluid travel time on solute flux has been recognized as a key complexity in the interpretation of solute concentrations, particularly in upland watersheds characterized by fracture flowpaths, as is typical of shale-dominated landscapes. Though recent studies have suggested a variety of models for solute generation in such dual (matrix and fracture flow) domain systems, a central impediment to advancing prediction is the lack of direct observations. Here, we report solute chemistry as a function of depth across an 18 m thick vadose zone of weathered argillite (shale) in the Eel River Critical Zone Observatory (ERCZO) using novel sub-horizontal distributed samplers (Vadose Zone Monitoring System). We contrast a year of major and trace ion chemistry obtained from water samples collected approximately biweekly using two complementary sampling systems, one applying active pressure to extract matrix-bound pore fluid, and the other using a passive collection method to extract freely draining water. Precipitation falling during the winter rainy season passes through this vadose zone, causing increased rock moisture that is subsequently depleted by transpiring trees. Solute concentrations reflect these seasonal changes, and, surprisingly, normalized ion ratios span the full range of values reported for the world's largest rivers. Notably, for some major cations, freely draining water is consistently less concentrated than matrix-bound water, and the composition of vadose zone water is consistently more variable than the underlying groundwater. Dual domain 1D reactive transport simulations demonstrate that even a simplified scoping model for solute concentrations across fractured shale systems requires a non-uniform fluid travel time to reasonably reproduce observations.

  5. Selectivity enhancement in photoacoustic gas analysis via phase-sensitive detection at high modulation frequency

    NASA Technical Reports Server (NTRS)

    Kosterev, Anatoliy (Inventor)

    2010-01-01

    A method for detecting a target fluid in a fluid sample comprising a first fluid and the target fluid using photoacoustic spectroscopy (PAS), comprises a) providing a light source configured to introduce an optical signal having at least one wavelength into the fluid sample; b) modulating the optical signal at a desired modulation frequency such that the optical signal generates an acoustic signal in the fluid sample; c) measuring the acoustic signal in a resonant acoustic detector; and d) using the phase of the acoustic signal to detect the presence of the target fluid.

  6. Dietary and fluid restriction perceptions of patients undergoing haemodialysis: an exploratory study.

    PubMed

    Hong, Leting Isabella; Wang, Wenru; Chan, Ee Yuee; Mohamed, Fatimah; Chen, Hui-Chen

    2017-11-01

    To explore the perspectives of patients undergoing haemodialysis in Singapore on an imposed dietary and fluid restriction regime. Adherence to prescribed dietary and fluid restriction constructs the fundamental basis of self-care with improved morbidity and mortality. However, most patients have struggled to adhere in this aspect. Existing studies have presented limited understanding on the facilitators and barriers of dietary and fluid adherence among haemodialysis patients. An exploratory qualitative study. A purposive sample of 14 patients undergoing haemodialysis was recruited from a renal unit of a tertiary hospital in Singapore. Data were collected through face-to-face individual interviews and subsequently analysed by thematic analysis. Four themes emerged: (1) Pessimism, (2) Existing struggles, (3) Perceived quality of support, and (4) Immensity of self-discipline. The imposed dietary and fluid restriction is a constant struggle and a cause of suffering among haemodialysis patients in Singapore. Nonetheless, they are generally submissive to their fluid restrictions for the sake of survival or to meet the expectations of their loved ones. The imposed dietary restrictions are generally neglected. The findings from this study can provide useful information in reviewing existing educational strategies, policies and nursing care. This is especially important because most patients exhibit high reliance on healthcare professionals. © 2017 John Wiley & Sons Ltd.

  7. A simple and inexpensive technique for assessing microbial contamination during drilling operations

    NASA Astrophysics Data System (ADS)

    Friese, André; Vuillemin, Aurèle; Kallmeyer, Jens; Wagner, Dirk

    2016-04-01

    Exploration of the Deep Biosphere relies on drilling, which inevitably causes infiltration of drilling fluids, containing allochthonous microbes from the surface, into the core. Therefore it is absolutely necessary to trace contamination of the sediment core in order to identify uncontaminated samples for microbiological investigations. Several techniques have been used in the past, including fluorescent dyes, perfluorocarbon tracers and fluorescent microspheres. Fluorescent dyes are inexpensive and easy to analyze on-site but are sensitive to light, pH and water chemistry. Furthermore, significant sorption to clays can decrease the fluorescence signal. Perfluorocarbon tracers are chemically inert hydrophobic compounds that can be detected with high sensitivity via gas chromatography, which might be a problem for on-site analysis. Samples have to be taken immediately after core retrieval as otherwise the volatile tracer will have diffused out of the core. Microsphere tracers are small (0.2 - 0.5 μm diameter) fluorescent plastic particles that are mixed into the drilling fluid. For analysis, these particles can be extracted from the sediment sample, transferred onto a filter and quantified via fluorescence microscopy. However, they are very expensive and therefore unsuitable for deep drilling operations that need large amounts of drilling fluids. Here, we present an inexpensive contamination control approach using fluorescent pigments initially used for coloring plastics. The price of this tracer is nearly three orders of magnitude lower than conventional microsphere tracers. Its suitability for large drilling campaigns was tested at the ICDP Deep Drilling at Lake Towuti, Sulawesi, Indonesia. The tracer was diluted 1:1000 in lake water, which was used as the drilling fluid. Additionally, a plastic bag filled with 20 mL of undiluted tracer was attached to the core catcher to increase the amount of particles in the liner fluid right at the core. After core retrieval, the core was cut and the liner fluid collected. From each whole round core (WRC) that was taken for microbiological and biogeochemical analyses, small samples of 1 cc were retrieved with sterile cutoff syringes from the rim, the center and an intermediate position. After dilution and homogenization in 9 mL MilliQ water, 10 μL of the sediment slurry was transferred onto a filter membrane and particles counted via fluorescence microscopy. Additionally, particles in the liner fluid were also quantified. This allows the quantification of the amount of drilling fluid that has entered the sediment sample during drilling. The minimum detectable volume of drilling fluid was in the order of single nanoliters per cc of sediment, which is in the range of established techniques. The presented method requires only a minimum of equipment and allows rapid determination of contamination in the sediment core and an easy to handle on-site analysis at low costs. The sensitivity is in the same range as perfluorocarbon and microsphere tracer applications. Thus, it offers an inexpensive but powerful technique for contamination assessment for future drilling campaigns.

  8. Intraosseous samples can be used for opioid measurements--an experimental study in the anaesthetized pig.

    PubMed

    Larsson, Torsten; Strandberg, Gunnar; Eriksson, Mats; Bondesson, Ulf; Lipcsey, Miklos; Larsson, Anders

    2013-03-01

    The intraosseous route provides access to the systemic circulation in an emergency situation when other forms of vascular access are unavailable and there is an urgent need for fluid or drug therapy. The intraosseous access has also been used for collecting samples for laboratory testing. A question that may arise in an unconscious or severely exhausted patient is whether this condition is caused by an unknown drug. We aimed to evaluate whether intraosseous samples could be used to measure opioids and to study the accuracy and precision of such measurements. Five healthy, anaesthetized pigs were treated with a continuous morphine infusion as part of the anaesthesia procedure. Samples for morphine testing were collected hourly for 6 h from two tibial intraosseous cannulae and a central venous catheter. The differences in morphine concentrations between the two tibial intraosseous cannulae were less than 10% in 32/33 times. The values were also relatively stable over time. Our findings suggest that intraosseous samples can be used for the analysis of opioids if an IV route is not available.

  9. The influence of contrast media on kidney function in patients with stable coronary artery disease.

    PubMed

    Reuter, Simon Bertram; Harutyunyan, Marina; Mygind, Naja Dam; Jørgensen, Erik; Kastrup, Jens

    2014-08-01

    To investigate the incidence of contrast media-induced nephropathy (CIN) in patients with stable coronary artery disease (CAD) referred for elective coronary intervention following hydration routines. The reversibility of CIN was followed in a 6 month-period. A total of 447 patients referred for elective coronary intervention due to suspected CAD were included. Blood samples were collected before and 24 h after intervention and medical records were obtained. Patients had no drinking fluid restrictions and were routinely treated with a 1000 ml saline infusion. All patients were invited to a 6-month examination and collection of blood samples. A total of 19 patients (4.3%) developed CIN. CIN patients had a pre-investigation higher estimated glomerular filtration rate (eGRF), lower level of kidney failure and lower creatinine level than non-CIN patients. Kidney function was not normalized in CIN patients 6 months after the intervention. Two patients still met the definition of CIN. With no restriction in fluid intake and supplementary infusion of saline, only a few patients with stable CAD developed early indications of CIN during elective coronary interventions. Kidney function and the amount of contrast media used was not a predictor of CIN development. The induced CIN was not completely normalized in a 6-month follow-up period.

  10. Distribution and Characteristics of Seafloor Seepage Features in the Active Margin Offshore of SW Taiwan

    NASA Astrophysics Data System (ADS)

    Chen, T. T.; Hsu, H. H.; Liu, C. S.; Su, C. C.; Paull, C. K.; Chen, Y. H.; Caress, D. W.; Gwiazda, R.; Lundsten, E. M.

    2017-12-01

    In the active margin offshore of southwest (SW) Taiwan, west-vergent imbricated thrusts, folds and dipping strata are the main structural features. This is also the area where gas hydrates are widely distributed beneath the seafloor. Fluids from deep strata may migrate upwards along porous dipping layers or faults and then vent out to form seafloor seepage features in many of the gas hydrate prospects. A joint survey was conducted in May 2017 using MBARI mapping AUV and miniROV to investigate the seafloor seepage features. Numerous comet-shaped depressions (CSD) are mapped along flanks of several anticlinal ridges, and four carbonate mounds around CSD are observed from the ultra-high-resolution (1-m lateral resolution) bathymetry data collected by AUV. Samples of the carbonate mounds were collected by the mini-ROV, and their mineral compositions contain dolomite and ankerite. The AUV collected chirp sonar profiles and previously collected surface ship multichannel seismic reflection profiles across these seafloor features show that potential fluid migration pathways connect free gas trapped below the base of gas hydrate stability zone and the seafloor in the vicinity of these features. Our study suggests that the CSD could be an indicator of seafloor seepage and may be distribution widely in the active margin setting.

  11. Cool seafloor hydrothermal springs reveal global geochemical fluxes

    NASA Astrophysics Data System (ADS)

    Wheat, C. Geoffrey; Fisher, Andrew T.; McManus, James; Hulme, Samuel M.; Orcutt, Beth N.

    2017-10-01

    We present geochemical data from the first samples of spring fluids from Dorado Outcrop, a basaltic edifice on 23 M.y. old seafloor of the Cocos Plate, eastern Pacific Ocean. These samples were collected from the discharge of a cool hydrothermal system (CHS) on a ridge flank, where typical reaction temperatures in the volcanic crust are low (2-20 °C) and fluid residence times are short. Ridge-flank hydrothermal systems extract 25% of Earth's lithospheric heat, with a global discharge rate equivalent to that of Earth's river discharge to the ocean; CHSs comprise a significant fraction of this global flow. Upper crustal temperatures around Dorado Outcrop are ∼15 °C, the calculated residence time is <3 y, and the composition of discharging fluids is only slightly altered from bottom seawater. Many of the major ions concentrations in spring fluids are indistinguishable from those of bottom seawater; however, concentrations of Rb, Mo, V, U, Mg, phosphate, Si and Li are different. Applying these observed differences to calculated global CHS fluxes results in chemical fluxes for these ions that are ≥15% of riverine fluxes. Fluxes of K and B also may be significant, but better analytical resolution is required to confirm this result. Spring fluids also have ∼50% less dissolved oxygen (DO) than bottom seawater. Calculations of an analytical model suggest that the loss of DO occurs primarily (>80%) within the upper basaltic crust by biotic and/or abiotic consumption. This calculation demonstrates that permeable pathways within the upper crust can support oxic water-rock interactions for millions of years.

  12. Analysis of nifedipine in human plasma and amniotic fluid by liquid chromatography-tandem mass spectrometry and its application to clinical pharmacokinetics in hypertensive pregnant women.

    PubMed

    Filgueira, Gabriela Campos de Oliveira; Filgueira, Osmany Alberto Silva; Carvalho, Daniela Miarelli; Marques, Maria Paula; Moisés, Elaine Christine Dantas; Duarte, Geraldo; Lanchote, Vera Lucia; Cavalli, Ricardo Carvalho

    2015-07-01

    Nifedipine is a dihydropyridine calcium channel blocker used for the treatment of hypertension in pregnant women. A liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated for analysis of nifedipine in human plasma and amniotic fluid. Separation of nifedipine and nitrendipine (IS) was performed using a LiChroCART(®) RP-Select B column and a mixture of water:acetonitrile:glacial acetic acid (30:70:0.5 v/v) as the mobile phase. Aliquots of 500μL of biological samples were extracted at pH 13 using dichloromethane:n-pentane (3:7 v/v). The validated method was applied to a study of the pharmacokinetics of nifedipine in human plasma and amniotic fluid samples collected up to 12h after administration of the last slow-release nifedipine (20mg/12h) dose to 12 hypertensive pregnant women. The estimated pharmacokinetic parameters of nifedipine showed a mean AUC(0-12) of 250.2ngh/mL, ClT/F of 89.2L/h, Vd/F of 600.0L and t1/2 5.1h. The mean amniotic fluid/plasma concentration ratio was 0.05. The methods proved to be highly sensitive by showing a lower quantification limit of 0.1ng/mL for both matrices. And this study reports for the first time the complete development and validation of the method to quantify nifedipine in amniotic fluid using LC-MS-MS. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. Comparison of salivary collection and processing methods for quantitative HHV-8 detection.

    PubMed

    Speicher, D J; Johnson, N W

    2014-10-01

    Saliva is a proved diagnostic fluid for the qualitative detection of infectious agents, but the accuracy of viral load determinations is unknown. Stabilising fluids impede nucleic acid degradation, compared with collection onto ice and then freezing, and we have shown that the DNA Genotek P-021 prototype kit (P-021) can produce high-quality DNA after 14 months of storage at room temperature. Here we evaluate the quantitative capability of 10 collection/processing methods. Unstimulated whole mouth fluid was spiked with a mixture of HHV-8 cloned constructs, 10-fold serial dilutions were produced, and samples were extracted and then examined with quantitative PCR (qPCR). Calibration curves were compared by linear regression and qPCR dynamics. All methods extracted with commercial spin columns produced linear calibration curves with large dynamic range and gave accurate viral loads. Ethanol precipitation of the P-021 does not produce a linear standard curve, and virus is lost in the cell pellet. DNA extractions from the P-021 using commercial spin columns produced linear standard curves with wide dynamic range and excellent limit of detection. When extracted with spin columns, the P-021 enables accurate viral loads down to 23 copies μl(-1) DNA. The quantitative and long-term storage capability of this system makes it ideal for study of salivary DNA viruses in resource-poor settings. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  14. Elastase, alpha2-macroglobulin and alkaline phosphatase in crevicular fluid from implants with and without periimplantitis.

    PubMed

    Plagnat, Dominique; Giannopoulou, Catherine; Carrel, Anne; Bernard, Jean-Pierre; Mombelli, Andrea; Belser, Urs C

    2002-06-01

    The aim of this investigation was to determine the presence of selected enzymes and enzyme inhibitors in crevicular fluid collected from implants with and without clinical, radiographic and microbiological signs of periimplantitis. Eleven implants with symptoms of periimplantitis in eight patients (four men and four women) were compared to eleven implants in seven subjects (one man and six women) without periimplantitis. Periimplant crevicular fluid (PICF) was collected at the mesial and distal sites of each implant. Alkaline phosphatase activity (ALP) was measured by using p-nitrophenyl-phosphate as substrate, elastase activity (EA) by the use of a low molecular weight fluorogenic substrate, and the inhibitor alpha2-macroglobulin (alpha2M) by ELISA. ALP, EA and alpha2M were detected in the majority of samples in both groups. In comparison to the clinically healthy implants, total amounts of each of these substances were significantly higher in PICF collected around implants with periimplantitis. The mean total amounts of EA, alpha2M and ALP in the healthy group were: EA: 1.8 ng, alpha2M: 3.1 ng, ALP: 24.1 U, and in the periimplantitis group EA: 23.1 ng, alpha2M: 25.2 ng and ALP: 142.3 U. In addition, all three mediators were correlated with the clinical parameters. The results confirm the similarity of the inflammatory response of tissues surrounding implants and natural teeth, and suggest that ALP and EA could be promising markers of bone loss around dental implants.

  15. [Frequency of yeasts in vaginal fluid of women with and without clinical suspicion of vulvovaginal candidiasis].

    PubMed

    Andrioli, João Luciano; Oliveira, Gílvia Simone Andrade; Barreto, Cilene Souza; Sousa, Zulane Lima; Oliveira, Maria Cristina Haun de; Cazorla, Irene Mauricio; Fontana, Renato

    2009-06-01

    to study vulvovaginal candidiasis from the vaginal fluid of women with and without clinical suspicion, identifying the frequency of Candida spp., and associating it with intrinsic and extrinsic risk factors. a total of 286 samples from patients attended in private practices and public health units from August 2005 to August 2007 were collected, being 121 women under clinical suspicion and 165, without. The samples were collected with sterile swabs, taken to the laboratory in 0.85% physiological solution, and then seeded in CHROMagar Candida and in 4% agar Sabourad with chloramphenicol. Classical identification procedures were carried out: macro and micromorphology, zymogram and auxanogram. Data obtained were analyzed by frequency tests and contingency tables (chi2). a total of 47.9% of the women under clinical suspicion got confirmation of candidiasis by the laboratorial tests. Among the patients without clinical suspicion (Control Group), 78.2% were vulvovaginal candidiasis negative according to the laboratorial tests. Candida albicans was the prevalent strain in 74.5% of the cases. There were significant differences among the positive cases, according to the patients from the two cities evaluated (p<0.05). Clothing was one differential aspect found among the two populations studied. the presence of predisposing factors does not necessarily define vulvovaginal candidiasis. Geographical localization has shown to be a relevant factor in the distribution of events. The type of clothing may be one of the reasons for it. Culture of samples from the vaginal contents, followed by microorganisms' identification, can be important.

  16. A quantitative PCR method for assessing the presence of Pasteurella testudinis DNA in nasal lavage samples from the desert tortoise (Gopherus agassizii).

    PubMed

    duPre', S A; Tracy, C R; Sandmeier, F C; Hunter, K W

    2012-12-01

    Pasteurella testudinis has been associated with upper respiratory tract disease (URTD) in the threatened desert tortoise (Gopherus agassizii). Our goal was to develop a sensitive and specific qPCR method for detecting DNA from P. testudinis in nasal lavage fluid collected from desert tortoises in the field. Probes for 16S ribosomal RNA and RNA polymerase β-subunit (rpoB) genes were designed. A standard curve generated with DNA extracted from known numbers of bacterial cells determined by flow cytometry revealed a lower detection limit of 50 fg/ml (10 bacteria/ml). The nasal lavage fluid contained no interfering substances, and the qPCR method did not recognize normal flora DNA. The nasal lavage samples from 20 desert tortoises captured in Clark County, Nevada, USA in 2007 and housed at the Desert Tortoise Conservation Center, were all positive for P. testudinis DNA by qPCR. Another set of 19 lavage samples collected in 2010 from wild desert tortoises in the Mojave Desert were tested and 84% were positive for P. testudinis DNA. Fully validated, this qPCR method will provide a means of determining colonization rate. When used in conjunction with serological methods and clinical evaluations, both infection rate and disease rate can be determined for this potential URTD pathogen. This new assay provides an important tool for managing the threatened populations of the Mojave Desert tortoise. Copyright © 2012 Elsevier B.V. All rights reserved.

  17. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Takahashi, Eri, E-mail: eritakahashi@fc.kuh.kumamoto-u.ac.jp; Fukushima, Ayako; Haga, Akira

    In rhegmatogenous retinal detachment (RRD), scattered RPE cells from the basement membrane into the vitreous cavity undergo an epithelial mesenchymal transition (EMT) and form the intraocular fibrous membrane in response to vitreous fluid. We investigated whether exposure to vitreous samples was associated with EMT-associated signals and mesenchymal characters. Human vitreous samples were collected from patients with RRD, epiretinal membrane (ERM), or macular hole (MH). We evaluated the effects of vitreous on ARPE-19 cells in suspension cultures using poly 2-hydroxyethyl methacrylate-coated dishes and three-dimensional (3D) Matrigel cultures. We found that exposure to vitreous samples did not induce morphological changes or accelerate woundmore » closure in monolayers. Several samples showed increased phosphorylation of Smad2 and nuclear translocation of nuclear factor-κB. Mechanical stress triggered an elevation of phosphorylation levels in Smad2. In addition, exposure to vitreous fluid increased the phosphorylation of p38 mitogen-activated protein kinase in cell suspension cultures after mechanical stress. Moreover, ARPE-19 cells showed a stellate invasive phenotype in 3D Matrigel cultures with vitreous samples. In this study, we demonstrated that mechanical stress and vitreous were associated with EMT-associated signals and invasive phenotypes in 3D cultures but not in monolayers. These results have important implications for the role of vitreous humor in the induction of EMT and intraocular fibrosis.« less

  18. Detection of major food allergens in amniotic fluid: initial allergenic encounter during pregnancy.

    PubMed

    Pastor-Vargas, Carlos; Maroto, Aroa S; Díaz-Perales, Araceli; Villalba, Mayte; Esteban, Vanesa; Ruiz-Ramos, Marta; de Alba, Marta Rodriguez; Vivanco, Fernando; Cuesta-Herranz, Javier

    2016-11-01

    Ingestion of food allergens present in maternal milk during breastfeeding has been hypothesized as a gateway to sensitization to food; however, this process could develop during pregnancy, as the maternal-fetal interface develops a Th2- and Treg-mediated environment to protect the fetus. We hypothesized that in these surroundings, unborn children are exposed to food allergens contained in the mother's diet, possibly giving rise to first sensitization. The presence of allergens in utero was studied by analyzing amniotic fluid (AF) samples in two different stages of pregnancy: at 15-20 weeks and after delivery at term. An antibody microarray was developed to test for the most common food allergens. The array detects the presence of ten allergens from milk, fruit, egg, fish, nuts, and wheat. AF from 20 pregnant women was collected: eight after delivery at term and 12 from women who underwent diagnostic amniocentesis between weeks 15 and 20 of gestation. The presence of allergens was detected in all samples. Samples from amniocentesis had a higher allergen concentration than samples after delivery at term. We demonstrated the presence of intact major food allergens in AF samples. This early contact could explain subsequent sensitization to foods never eaten before. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  19. Determination of the Landau Lifshitz damping parameter of composite magnetic fluids

    NASA Astrophysics Data System (ADS)

    Fannin, P. C.; Malaescu, I.; Marin, C. N.

    2007-01-01

    Measurements of the frequency dependent, complex magnetic susceptibility, χ(ω)= χ‧( ω)- iχ″( ω), in the GHz range, are used to investigate the effect which the mixing of two different magnetic fluids has on the value of the damping parameter, α, of the Landau-Lifshitz equation. The magnetic fluid samples investigated in this study were three kerosene-based magnetic fluids, stabilised with oleic acid, denoted as MF1, MF2 and MF3. Sample MF1 was a magnetic fluid with Mn 0.6Fe 0.4Fe 2O 4 particles, sample MF2 was a magnetic fluid with Ni 0.4Zn 0.6Fe 2O 4 particles and sample MF3 was a composite magnetic fluid obtained by mixing a part of sample MF1 with a part of sample MF2, in proportion of 1:1. The experimental results revealed that the value of the damping parameter of the composite sample (sample MF3) is between the α values obtained for its constituents (samples MF1 and MF2). Based on the superposition principle, which states that the susceptibility of a magnetic fluid sample is a superposition of individual contributions of the magnetic particles, a theoretical model is proposed. The experimental results are shown to be in close agreement with the theoretical results. This result is potentially useful in the design of microwave-operating materials, in that it enables one to determine a particular value of damping parameter.

  20. FLUID SELECTING APPARATUS

    DOEpatents

    Stinson, W.J.

    1958-09-16

    A valve designed to selectively sample fluids from a number of sources is described. The valve comprises a rotatable operating lever connected through a bellows seal to a rotatable assembly containing a needle valve, bearings, and a rotational lock. The needle valve is connected through a flexible tube to the sample fluid outlet. By rotating the lever the needle valve is placed over . one of several fluid sources and locked in position so that the fluid is traasferred through the flexible tubing and outlet to a remote sampling system. The fluids from the nonselected sources are exhausted to a waste line. This valve constitutes a simple, dependable means of selecting a sample from one of several scurces.