Sample records for fluids case study

  1. [Significance of amnioinfusion and amniotic fluid exchange under continuous internal fetal heart rate monitoring for management of fetal distress during labor].

    PubMed

    Zhao, S; Ai, L; Zhang, H

    2000-01-01

    To discuss the significance of amnioinfusion and amniotic fluid exchange under continuous internal fetal heart rate (FHR) monitoring for management of fetal distress during labor. 136 cases with frequent variable deceleration (VD) and meconium stained amniotic fluid during labor were divided into two groups: the study group (68 cases) and the control group (68 cases). The former were treated by amnioinfusion and amniotic fluid exchange, while oxygen inhalation, change of body position, and intravenous infusion for the control group. In the study group, VD disappeared or relieved in 62 cases obviously, and the efficacy rate reached 91.2% (62/68). 48 cases with II degree meconium stained amniotic fluid were treated by amniotic fluid exchange, amniotic fluid became clear or turned to I degree stained in 39 cases. In the control group, VD relieved in 20 cases, the efficacy rate was 19.4%, significantly lower than that of the study group (P < 0.01). In the study group, cesarean section rate was 14.7% neonatal asphyxia 7.4% while they were 47.1% and 48.5% in the control group respectively (P < 0.01; P < 0.01). Neonatal pneumonia caused by meconium aspiration occurred in 13 cases, meconium aspiration syndrome (MAS) 8 cases, with 5 newborns died in the control group, while there was no neonatal death in the study group. There was no significant difference on puerperal morbidity between the 2 groups (P > 0.05). Amnioinfusion and AF exchange during labor are one of the effective treatment methods for fetal distress and prevention for MAS.

  2. Role of intrapartum transcervical amnioinfusion in patients with meconium-stained amniotic fluid.

    PubMed

    Bhatia, Pushpa; Reena, Kumari; Nangia, Sangita

    2013-03-01

    The study was undertaken to evaluate maternal, perinatal outcomes following transcervical intrapartum amnioinfusion in women with meconium-stained amniotic fluid. A prospective comparative study was conducted on 100 women with meconium-stained amniotic fluid in labor. Group A: study group (50 cases) received amnioinfusion. Group B: control group (50 cases) did not receive amnioinfusion. FHR monitoring was done using cardiotocography. Significant relief from variable decelerations was seen in 68.18 % cases in the amnioinfusion group as compared to 7.1 % cases in the control group. 78 % cases who were given amnioinfusion had vaginal delivery as compared to 18 % cases in the control group. Fourteen percent cases in the study group had cesarean delivery as compared to 68 % cases in the control group. Meconium aspiration syndrome was seen in six percent neonates in the study group as compared to 20 % in the control group. Two neonates died in the control group due to meconium aspiration syndrome. There was no maternal mortality or major maternal complication. Intrapartum transcervical amnioinfusion is valuable in patients with meconium-stained amniotic fluid.

  3. Detection of Nitrobenzodiazepines and Their 7-Amino Metabolites in Oral Fluid.

    PubMed

    Vindenes, Vigdis; Strand, Dag Helge; Koksæter, Paul; Gjerde, Hallvard

    2016-05-01

    Clonazepam, nitrazepam and flunitrazepam are frequently used benzodiazepines, both as prescribed medication and as drugs of abuse. Little is, however, known about how these drugs are excreted in oral fluid. It has been claimed that the parent drugs are more likely to be detected in oral fluid than the 7-amino metabolites. The aim of this study was to investigate whether the parent drugs or the 7-amino metabolites of the nitrobenzodiazepines were most frequently detected in authentic oral fluid samples. Oral fluid samples were collected from patients undergoing opioid maintenance treatment. Cases where clonazepam, nitrazepam, flunitrazepam and/or their metabolites were detected were included. The samples were collected using the Intercept Oral Specimen Collection Device. A cutoff concentration of 1 nM (∼0.3 ng/mL) in oral fluid-buffer mixture was applied for all the substances. A total of 1,001 oral fluid samples were positive for clonazepam and/or 7-aminoclonazepam; both substances were detected in 707 samples, only the parent drug in 64 cases and only the metabolite in 230 cases. For nitrazepam, both substances were detected in 139 samples; only the parent drug in 16 cases and only the metabolite in 56 cases. Flunitrazepam only was not detected in any sample; both substances were detected in one of these cases, and only the metabolite in three cases. This study revealed that 7-amino metabolites were more likely to be detected in oral fluid than the parent drugs. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  4. Hierarchical Bayesian Modeling of Fluid-Induced Seismicity

    NASA Astrophysics Data System (ADS)

    Broccardo, M.; Mignan, A.; Wiemer, S.; Stojadinovic, B.; Giardini, D.

    2017-11-01

    In this study, we present a Bayesian hierarchical framework to model fluid-induced seismicity. The framework is based on a nonhomogeneous Poisson process with a fluid-induced seismicity rate proportional to the rate of injected fluid. The fluid-induced seismicity rate model depends upon a set of physically meaningful parameters and has been validated for six fluid-induced case studies. In line with the vision of hierarchical Bayesian modeling, the rate parameters are considered as random variables. We develop both the Bayesian inference and updating rules, which are used to develop a probabilistic forecasting model. We tested the Basel 2006 fluid-induced seismic case study to prove that the hierarchical Bayesian model offers a suitable framework to coherently encode both epistemic uncertainty and aleatory variability. Moreover, it provides a robust and consistent short-term seismic forecasting model suitable for online risk quantification and mitigation.

  5. On the micromechanics of slip events in sheared, fluid-saturated fault gouge

    NASA Astrophysics Data System (ADS)

    Dorostkar, Omid; Guyer, Robert A.; Johnson, Paul A.; Marone, Chris; Carmeliet, Jan

    2017-06-01

    We used a three-dimensional discrete element method coupled with computational fluid dynamics to study the poromechanical properties of dry and fluid-saturated granular fault gouge. The granular layer was sheared under dry conditions to establish a steady state condition of stick-slip dynamic failure, and then fluid was introduced to study its effect on subsequent failure events. The fluid-saturated case showed increased stick-slip recurrence time and larger slip events compared to the dry case. Particle motion induces fluid flow with local pressure variation, which in turn leads to high particle kinetic energy during slip due to increased drag forces from fluid on particles. The presence of fluid during the stick phase of loading promotes a more stable configuration evidenced by higher particle coordination number. Our coupled fluid-particle simulations provide grain-scale information that improves understanding of slip instabilities and illuminates details of phenomenological, macroscale observations.

  6. A study on the unsteady flow of two immiscible micropolar and Newtonian fluids through a horizontal channel: A numerical approach

    NASA Astrophysics Data System (ADS)

    Devakar, M.; Raje, Ankush

    2018-05-01

    The unsteady flow of two immiscible micropolar and Newtonian fluids through a horizontal channel is considered. In addition to the classical no-slip and hyper-stick conditions at the boundary, it is assumed that the fluid velocities and shear stresses are continuous across the fluid-fluid interface. Three cases for the applied pressure gradient are considered to study the problem: one with constant pressure gradient and the other two cases with time-dependent pressure gradients, viz. periodic and decaying pressure gradient. The Crank-Nicolson approach has been used to obtain numerical solutions for fluid velocity and microrotation for diverse sets of fluid parameters. The nature of fluid velocities and microrotation with various values of pressure gradient, Reynolds number, ratio of viscosities, micropolarity parameter and time is illustrated through graphs. It has been observed that micropolarity parameter and ratio of viscosities reduce the fluid velocities.

  7. K-11 students’ creative thinking ability on static fluid: a case study

    NASA Astrophysics Data System (ADS)

    Hanni, I. U.; Muslim; Hasanah, L.; Samsudin, A.

    2018-05-01

    Creative thinking is one of the fundamental components of 21st-century education that needs to be possessed and developed in students. Thus, the students have the ability to find many alternative solutions to solve problems in physics learning. The study aimed at providing the students’ creative thinking ability on Static Fluid. A case study has been implemented through a single case, namely embedded design. Participants in this study are 27 K-11 students. The instrument utilized is Test for Creative Thinking-Static Fluid (TCT-SF) which has been validated by the experts. The result shows that 10.74 (approximately 35.8%) of the maximum scores. In conclusion, students’ creative thinking ability on Static Fluid is still stumpy, hence, it is needed to develop creative thinking ability in K-11 students’ context.

  8. [Clinical evaluation of flomoxef in pediatrics and a study on the penetration into cerebrospinal fluid].

    PubMed

    Okada, T; Furukawa, S

    1987-08-01

    The transfer to cerebrospinal fluid of a new oxacephem antibiotic flomoxef (FMOX, 6315-S) and its clinical efficacy against bacterial infections were investigated. 1. In 3 cases of purulent meningitis, cerebrospinal fluid concentrations of FMOX after one shot intravenous injection of 100 mg/kg during the acute stage of infections were 5.12-6.32 micrograms/ml and ratios of FMOX in cerebrospinal fluid in serum were about 5%. During the recovery stage, cerebrospinal fluid concentrations were about 3.8 micrograms/ml and cerebrospinal fluid/serum ratios were about 3.5%. 2. In 1 case of purulent meningitis, the treatment with FMOX was clinically effective but this case was classified as "unevaluable" because other drug was used concomitantly. FMOX was rated effective in other 2 cases of purulent meningitis. Of 9 cases of pneumonia, FMOX was rated very effective in 8 cases and it was rated only effective in the other. Of 4 cases of bronchitis, the drug was rated very effective in 3 cases and only effective in the other. FMOX was rated very effective against 2 cases of tonsillitis, also. 3. As side effects, thrombocytosis was observed in 3 of 20 cases examined. All cases, however, were deemed unrelated to the FMOX treatment and the side effect was only transient as are often found in courses of recovery from infections.

  9. Prenatal diagnosis of Bartter syndrome: amniotic fluid aldosterone.

    PubMed

    Rachid, Myriam; Dreux, Sophie; Pean de Ponfilly, Gauthier; Vargas-Poussou, Rosa; Czerkiewicz, Isabelle; Chevenne, Didier; Oury, Jean-François; Deschênes, Georges; Muller, Françoise

    2017-04-01

    Bartter syndrome is a severe inherited tubulopathy characterized at birth by salt wasting, severe polyuria, dehydration, growth retardation and secondary hyperaldosteronism. Prenatally, the disease is usually discovered following onset of severe polyhydramnios. We studied amniotic fluid aldosterone concentration in cases of Bartter syndrome and in control groups. Amniotic fluid aldosterone was assayed by radioimmunoassay. We undertook a retrospective case-control study based on 36 cases of postnatally diagnosed Bartter syndrome and 144 controls matched for gestational age. Two controls groups were defined: controls with polyhydramnios (n=72) and control without polyhydramnios (n=72). Amniotic fluid aldosterone was compared between the three groups. The median amniotic fluid aldosterone concentration in the Bartter syndrome group (90 pg/mL) did not differ significantly from that in the controls with polyhydramnios (90 pg/mL, p=0.33) or the controls without polyhydramnios (87 pg/mL, p=0.41). In conclusion, amniotic fluid aldosterone assay cannot be used for prenatal diagnosis of Bartter syndrome.

  10. Interface behavior of a multi-layer fluid configuration subject to acceleration in a microgravity environment, supplement 1. M.S. Thesis

    NASA Technical Reports Server (NTRS)

    Lyell, M. J.; Roh, Michael

    1991-01-01

    With the increasing opportunities for research in a microgravity environment, there arises a need for understanding fluid mechanics under such conditions. In particular, a number of material processing configurations involve fluid-fluid interfaces which may experience instabilities in the presence of external forcing. In a microgravity environment, these accelerations may be periodic or impulse-type in nature. This research investigates the behavior of a multi-layer idealized fluid configuration which is infinite in extent. The analysis is linear, and each fluid region is considered inviscid, incompressible, and immiscible. An initial parametric study of confiquration stability in the presence of a constant acceleration field is performed. The zero mean gravity limit case serves as the base state for the subsequent time-dependent forcing cases. A stability analysis of the multi-layer fluid system in the presence of periodic forcing is investigated. Floquet theory is utilized. A parameter study is performed, and regions of stability are identified. For the impulse-type forcing case, asymptotic stability is established for the configuration. Using numerical integration, the time response of the interfaces is determined.

  11. Spinning fluids in general relativity

    NASA Technical Reports Server (NTRS)

    Ray, J. R.; Smalley, L. L.

    1982-01-01

    General relativity field equations are employed to examine a continuous medium with internal spin. A variational principle formerly applied in the special relativity case is extended to the general relativity case, using a tetrad to express the spin density and the four-velocity of the fluid. An energy-momentum tensor is subsequently defined for a spinning fluid. The equations of motion of the fluid are suggested to be useful in analytical studies of galaxies, for anisotropic Bianchi universes, and for turbulent eddies.

  12. Flow of “stress power-law” fluids between parallel rotating discs with distinct axes

    DOE PAGES

    Srinivasan, Shriram; Karra, Satish

    2015-04-16

    The problem of flow between parallel rotating discs with distinct axes corresponds to the case of flow in an orthogonal rheometer and has been studied extensively for different fluids since the instrument's inception. All the prior studies presume a constitutive prescription of the fluid stress in terms of the kinematical variables. In this paper, we approach the problem from a different perspective, i.e., a constitutive specification of the symmetric part of the velocity gradient in terms of the Cauchy stress. Such an approach ensures that the boundary conditions can be incorporated in a manner quite faithful to real world experimentsmore » with the instrument. Interestingly, the choice of the boundary condition is critical to the solvability of the problem for the case of creeping/Stokes flow. Furthermore, when the no-slip condition is enforced at the boundaries, depending on the model parameters and axes offset, the fluid response can show non-uniqueness or unsolvability, features which are absent in a conventional constitutive specification. In case of creeping/Stokes flow with prescribed values of the stress, the fluid response is indeterminate. We also record the response of a particular case of the given “stress power-law” fluid; one that cannot be attained by the conventional power-law fluids.« less

  13. Diagnostic Accuracy of Ascites Fluid Gross Appearance in Detection of Spontaneous Bacterial Peritonitis.

    PubMed

    Aminiahidashti, Hamed; Hosseininejad, Seyed Mohammad; Montazer, Hosein; Bozorgi, Farzad; Goli Khatir, Iraj; Jahanian, Fateme; Raee, Behnaz

    2014-01-01

    Spontaneous bacterial peritonitis (SBP) as a monomicrobial infection of ascites fluid is one of the most important causes of morbidity and mortality in cirrhotic patients. This study was aimed to determine the diagnostic accuracy of ascites fluid color in detection of SBP in cirrhotic cases referred to the emergency department. Cirrhotic patients referred to the ED for the paracentesis of ascites fluid were enrolled. For all studied patients, the results of laboratory analysis and gross appearance of ascites fluid registered and reviewed by two emergency medicine specialists. The sensitivity, specificity, positive and negative predictive value, and positive and negative likelihood ration of the ascites fluid gross appearance in detection of SBP were measured with 95% confidence interval. The present project was performed in 80 cirrhotic patients with ascites (52.5 female). The mean of the subjects' age was 56.25±12.21 years (35-81). Laboratory findings revealed SBP in 23 (29%) cases. Fifty nine (73%) cases had transparent ascites fluid appearance of whom 17 (29%) ones suffered from SBP. From 21 (26%) cases with opaque ascites appearance, 15 (71%) had SBP. The sensitivity and specificity of the ascites fluid appearance in detection of SBP were 46.88% (Cl: 30.87-63.55) and 87.50% (95% Cl: 75.3-94.14), respectively. It seems that the gross appearance of ascites fluid had poor diagnostic accuracy in detection of SBP and considering its low sensitivity, it could not be used as a good screening tool for this propose.

  14. Amniotic fluid embolism mortality rate.

    PubMed

    Benson, Michael D

    2017-11-01

    The objective of this study was to determine the mortality rate of amniotic fluid embolism (AFE) using population-based studies and case series. A literature search was conducted using the two key words: 'amniotic fluid embolism (AFE)' AND 'mortality rate'. Thirteen population-based studies were evaluated, as well as 36 case series including at least two patients. The mortality rate from population-based studies varied from 11% to 44%. When nine population-based studies with over 17 000 000 live births were aggregated, the maternal mortality rate was 20.4%. In contrast, the mortality rate of AFE in case series varies from 0% to 100% with numerous rates in between. The AFE mortality rate in population-based studies varied from 11% to 44% with the best available evidence supporting an overall mortality rate of 20.4%. Data from case series should no longer be used as a basis for describing the lethality of AFE. © 2017 Japan Society of Obstetrics and Gynecology.

  15. Vascular leakage in dengue--clinical spectrum and influence of parenteral fluid therapy.

    PubMed

    Rosenberger, Kerstin D; Lum, Lucy; Alexander, Neal; Junghanss, Thomas; Wills, Bridget; Jaenisch, Thomas

    2016-03-01

    Clinical management of dengue relies on careful monitoring of fluid balance combined with judicious intravenous (IV) fluid therapy. However, in patients with significant vascular leakage, IV fluids may aggravate serosal fluid accumulation and result in respiratory distress. Trained physicians followed suspected dengue cases prospectively at seven hospitals across Asia and Latin America, using a comprehensive case report form that included daily clinical assessment and detailed documentation of parenteral fluid therapy. Applying Cox regression, we evaluated risk factors for the development of shock or respiratory distress with fluid accumulation. Most confirmed dengue patients (1524/1734, 88%) never experienced dengue shock syndrome (DSS). Among those with DSS, 176/210 (84%) had fluid accumulation, and in the majority (83%), this was detectable clinically. Among all cases with clinically detectable fluid accumulation, 179/447 (40%) were diagnosed with shock or respiratory distress. The risk for respiratory distress with fluid accumulation increased significantly as the infused volume over the preceding 24 h increased (hazard ratio 1.18 per 10 ml/kg increase; P < 0.001). Longer duration of IV therapy, use of a fluid bolus in the preceding 24 h, female gender and poor nutrition also constituted independent risk factors. Shock and respiratory distress are relatively rare manifestations of dengue, but some evidence of fluid accumulation is seen in around 50% of cases. IV fluids play a crucial role in management, but they must be administered with caution. Clinically and/or radiologically detectable fluid accumulations have potential as intermediate severity endpoints for therapeutic intervention trials and/or pathogenesis studies. © 2016 John Wiley & Sons Ltd.

  16. Fluid Extravasation in Hip Arthroscopy: A Systematic Review.

    PubMed

    Ekhtiari, Seper; Haldane, Chloe E; de Sa, Darren; Simunovic, Nicole; Ayeni, Olufemi R

    2017-04-01

    The purpose of this systematic review was to (1) characterize cases of fluid extravasation during hip arthroscopy and explore common factors among them and (2) describe management strategies and outcomes of this complication. The databases MEDLINE, EMBASE, and PubMed were searched and screened in duplicate. Data regarding patient demographics, fluid management, presentation, management, and outcomes were collected. Study quality was assessed in duplicate using the Methodological Index for Non-Randomized Studies Criteria. Fourteen studies (1,286 patients) were included. Twenty-two occurrences of symptomatic fluid extravasation were reported in 21 patients (1.6% of total patients; one patient had fluid extravasation during 2 separate hip arthroscopies). Two studies of normal fluid extravasation in asymptomatic patients reported 1.13 to 3.06 L of extravasated fluid observed on computed tomography. Nine case studies were included, which provided detailed patient and surgical information. Of these 9 patients (10 cases) with a mean age of 38.2 years old (range, 15 to 55 years), 6 were female. Signs of fluid extravasation included abdominal distension (89%), hypothermia (56%), hypotension. and metabolic acidosis (33% each). Four patients required surgical intervention, while 3 underwent paracentesis. Two patients were managed conservatively. All patients stabilized and were discharged, with one patient reporting abdominal complaints at latest follow-up (length of follow-up unspecified). Fluid extravasation is a rare but potentially life-threatening complication of hip arthroscopy. It is important for surgeons and anaesthesiologists to be aware of its existence in order to recognize and manage it promptly. Most patients require interventional management by surgery or paracentesis, but some stabilize with conservative management. Level IV, systematic review of Level IV studies. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  17. Three-dimensional fluid-structure interaction case study on cubical fluid cavity with flexible bottom

    NASA Astrophysics Data System (ADS)

    Ghelardi, Stefano; Rizzo, Cesare; Villa, Diego

    2017-12-01

    In this paper, we report our study on a numerical fluid-structure interaction problem originally presented by Mok et al. (2001) in two dimensions and later studied in three dimensions by Valdés Vazquez (2007), Lombardi (2012), and Trimarchi (2012). We focus on a 3D test case in which we evaluated the sensitivity of several input parameters on the fluid and structural results. In particular, this analysis provides a starting point from which we can look deeper into specific aspects of these simulations and analyze more realistic cases, e.g., in sails design. In this study, using the commercial software ADINA™, we addressed a well-known unsteadiness problem comprising a square box representing the fluid domain with a flexible bottom modeled with structural shell elements. We compared data from previously published work whose authors used the same numerical approach, i.e., a partitioned approach coupling a finite volume solver (for the fluid domain) and a finite element solver (for the solid domain). Specifically, we established several benchmarks and made comparisons with respect to fluid and solid meshes, structural element types, and structural damping, as well as solution algorithms. Moreover, we compared our method with a monolithic finite element solution method. Our comparisons of new and old results provide an outline of best practices for such simulations.

  18. Diagnostic Accuracy of Ascites Fluid Gross Appearance in Detection of Spontaneous Bacterial Peritonitis

    PubMed Central

    Aminiahidashti, Hamed; Hosseininejad, Seyed Mohammad; Montazer, Hosein; Bozorgi, Farzad; Goli Khatir, Iraj; Jahanian, Fateme; Raee, Behnaz

    2014-01-01

    Introduction: Spontaneous bacterial peritonitis (SBP) as a monomicrobial infection of ascites fluid is one of the most important causes of morbidity and mortality in cirrhotic patients. This study was aimed to determine the diagnostic accuracy of ascites fluid color in detection of SBP in cirrhotic cases referred to the emergency department. Methods: Cirrhotic patients referred to the ED for the paracentesis of ascites fluid were enrolled. For all studied patients, the results of laboratory analysis and gross appearance of ascites fluid registered and reviewed by two emergency medicine specialists. The sensitivity, specificity, positive and negative predictive value, and positive and negative likelihood ration of the ascites fluid gross appearance in detection of SBP were measured with 95% confidence interval. Results: The present project was performed in 80 cirrhotic patients with ascites (52.5 female). The mean of the subjects’ age was 56.25±12.21 years (35-81). Laboratory findings revealed SBP in 23 (29%) cases. Fifty nine (73%) cases had transparent ascites fluid appearance of whom 17 (29%) ones suffered from SBP. From 21 (26%) cases with opaque ascites appearance, 15 (71%) had SBP. The sensitivity and specificity of the ascites fluid appearance in detection of SBP were 46.88% (Cl: 30.87-63.55) and 87.50% (95% Cl: 75.3-94.14), respectively. Conclusion: It seems that the gross appearance of ascites fluid had poor diagnostic accuracy in detection of SBP and considering its low sensitivity, it could not be used as a good screening tool for this propose. PMID:26495366

  19. Integrated Project Management: A Case Study in Integrating Cost, Schedule, Technical, and Risk Areas

    NASA Technical Reports Server (NTRS)

    Smith, Greg

    2004-01-01

    This viewgraph presentation describes a case study as a model for integrated project management. The ISS Program Office (ISSPO) developed replacement fluid filtration cartridges in house for the International Space Station (ISS). The presentation includes a step-by-step procedure and organizational charts for how the fluid filtration problem was approached.

  20. Closed-loop assisted versus manual goal-directed fluid therapy during high-risk abdominal surgery: a case-control study with propensity matching.

    PubMed

    Rinehart, Joseph; Lilot, Marc; Lee, Christine; Joosten, Alexandre; Huynh, Trish; Canales, Cecilia; Imagawa, David; Demirjian, Aram; Cannesson, Maxime

    2015-03-19

    Goal-directed fluid therapy strategies have been shown to benefit moderate- to high-risk surgery patients. Despite this, these strategies are often not implemented. The aim of this study was to assess a closed-loop fluid administration system in a surgical cohort and compare the results with those for matched patients who received manual management. Our hypothesis was that the patients receiving closed-loop assistance would spend more time in a preload-independent state, defined as percentage of case time with stroke volume variation less than or equal to 12%. Patients eligible for the study were all those over 18 years of age scheduled for hepatobiliary, pancreatic or splenic surgery and expected to receive intravascular arterial blood pressure monitoring as part of their anesthetic care. The closed-loop resuscitation target was selected by the primary anesthesia team, and the system was responsible for implementation of goal-directed fluid therapy during surgery. Following completion of enrollment, each study patient was matched to a non-closed-loop assisted case performed during the same time period using a propensity match to reduce bias. A total of 40 patients were enrolled, 5 were ultimately excluded and 25 matched pairs were selected from among the remaining 35 patients within the predefined caliper distance. There was no significant difference in fluid administration between groups. The closed-loop group spent a significantly higher portion of case time in a preload-independent state (95 ± 6% of case time versus 87 ± 14%, P =0.008). There was no difference in case mean or final stroke volume index (45 ± 10 versus 43 ± 9 and 45 ± 11 versus 42 ± 11, respectively) or mean arterial pressure (79 ± 8 versus 83 ± 9). Case end heart rate was significantly lower in the closed-loop assisted group (77 ± 10 versus 88 ± 13, P =0.003). In this case-control study with propensity matching, clinician use of closed-loop assistance resulted in a greater portion of case time spent in a preload-independent state throughout surgery compared with manual delivery of goal-directed fluid therapy. ClinicalTrials.gov Identifier: NCT02020863. Registered 19 December 2013.

  1. Long-term dietary sodium, potassium and fluid intake; exploring potential novel risk factors for renal cell cancer in the Netherlands Cohort Study on diet and cancer.

    PubMed

    Deckers, I A G; van den Brandt, P A; van Engeland, M; Soetekouw, P M M B; Baldewijns, M M L L; Goldbohm, R A; Schouten, L J

    2014-02-04

    As sodium, potassium and fluid intake are related to hypertension, an established risk factor for renal cell cancer (RCC), they may be independent risk factors for RCC. The Netherlands Cohort Study (NLCS) with case-cohort design included 120,852 participants aged 55-69 years. At baseline, diet and lifestyle were assessed with questionnaires. After 17.3 years of follow-up, 485 RCC cases and 4438 subcohort members were available for analyses. Sodium intake increased RCC risk (P-trend=0.03), whereas fluid and potassium intake did not. For high sodium and low fluid intake, the RCC risk additionally increased (P-interaction=0.02). Sodium intake is a potential risk factor for RCC, particularly if fluid consumption is low.

  2. GPU accelerated simulations of three-dimensional flow of power-law fluids in a driven cube

    NASA Astrophysics Data System (ADS)

    Jin, K.; Vanka, S. P.; Agarwal, R. K.; Thomas, B. G.

    2017-01-01

    Newtonian fluid flow in two- and three-dimensional cavities with a moving wall has been studied extensively in a number of previous works. However, relatively a fewer number of studies have considered the motion of non-Newtonian fluids such as shear thinning and shear thickening power law fluids. In this paper, we have simulated the three-dimensional, non-Newtonian flow of a power law fluid in a cubic cavity driven by shear from the top wall. We have used an in-house developed fractional step code, implemented on a Graphics Processor Unit. Three Reynolds numbers have been studied with power law index set to 0.5, 1.0 and 1.5. The flow patterns, viscosity distributions and velocity profiles are presented for Reynolds numbers of 100, 400 and 1000. All three Reynolds numbers are found to yield steady state flows. Tabulated values of velocity are given for the nine cases studied, including the Newtonian cases.

  3. The Clinical Significance of Eosinophils in the Amniotic Fluid in Preterm Labor

    PubMed Central

    ROMERO, ROBERTO; KUSANOVIC, JUAN PEDRO; GOMEZ, RICARDO; LAMONT, RONALD; BYTAUTIENE, EGLE; GARFIELD, ROBERT E.; MITTAL, POOJA; HASSAN, SONIA S.; YEO, LAMI

    2012-01-01

    Objective White blood cells are not traditionally considered to be normally present in amniotic fluid. This study was conducted after the observation that a patient with preterm labor and intact membranes had eosinophils as a predominant cell in the amniotic fluid, and had an episode of asthma during the index pregnancy. The goal of this study was to determine whether women presenting with preterm labor with eosinophils in the amniotic fluid had a different outcome than those without eosinophils as the predominant white blood cell in the amniotic cavity. Methods This retrospective case-control study included women who presented with preterm labor and intact membranes between 24 and 34 weeks of gestation. Patients underwent an amniocentesis shortly after admission for the assessment of the microbiologic status of the amniotic cavity and/or fetal lung maturity. Amniotic fluid was cultured for aerobic and anaerobic bacteria as well as genital mycoplasmas. Cytologic studies included amniotic fluid white blood cell count and differential, which was performed on cytocentrifuged specimens. Patients with microbial invasion of the amniotic cavity and/or a white blood cell count >20 cells/mm3 were excluded from the study. Cases were defined as women in whom the differential contained >20% of eosinophils. Controls were selected among women with an amniotic fluid eosinophil count ≤20% and matched for gestational age at amniocentesis. The analysis was conducted with non-parametric statistics. Results The study population consisted of 10 cases and 50 controls. Gestational age and cervical dilatation at admission were similar in both groups. Cases had a lower gestational age at delivery than controls [34.6 weeks, inter-quartile range (IQR) 32–37.3 weeks vs. 38.0 weeks, IQR 35–40 weeks, respectively; p=0.018]. The prevalence of preterm delivery ≤35 weeks was higher among patients who had >20% eosinophils than in the control group [50% (5/10) vs. 18% (9/50), respectively; p=0.029]. Similar results were observed for delivery at <37 weeks [Cases: 70% (7/10) vs. Controls: 36% (18/50); p=0.046]. Conclusions Women with preterm labor and intact membranes who have a large proportion of eosinophils in the amniotic fluid are at an increased risk for spontaneous preterm delivery. These patients may have had an episode of preterm labor related to a type I hypersensitivity reaction. PMID:19900034

  4. The impact of splay faults on fluid flow, solute transport, and pore pressure distribution in subduction zones: A case study offshore the Nicoya Peninsula, Costa Rica

    NASA Astrophysics Data System (ADS)

    Lauer, Rachel M.; Saffer, Demian M.

    2015-04-01

    Observations of seafloor seeps on the continental slope of many subduction zones illustrate that splay faults represent a primary hydraulic connection to the plate boundary at depth, carry deeply sourced fluids to the seafloor, and are in some cases associated with mud volcanoes. However, the role of these structures in forearc hydrogeology remains poorly quantified. We use a 2-D numerical model that simulates coupled fluid flow and solute transport driven by fluid sources from tectonically driven compaction and smectite transformation to investigate the effects of permeable splay faults on solute transport and pore pressure distribution. We focus on the Nicoya margin of Costa Rica as a case study, where previous modeling and field studies constrain flow rates, thermal structure, and margin geology. In our simulations, splay faults accommodate up to 33% of the total dewatering flux, primarily along faults that outcrop within 25 km of the trench. The distribution and fate of dehydration-derived fluids is strongly dependent on thermal structure, which determines the locus of smectite transformation. In simulations of a cold end-member margin, smectite transformation initiates 30 km from the trench, and 64% of the dehydration-derived fluids are intercepted by splay faults and carried to the middle and upper slope, rather than exiting at the trench. For a warm end-member, smectite transformation initiates 7 km from the trench, and the associated fluids are primarily transmitted to the trench via the décollement (50%), and faults intercept only 21% of these fluids. For a wide range of splay fault permeabilities, simulated fluid pressures are near lithostatic where the faults intersect overlying slope sediments, providing a viable mechanism for the formation of mud volcanoes.

  5. The role of synovial fluid analysis in the detection of periprosthetic hip and knee infections: a systematic review and meta-analysis.

    PubMed

    De Fine, Marcello; Giavaresi, Gianluca; Fini, Milena; Illuminati, Andrea; Terrando, Silvio; Pignatti, Giovanni

    2018-05-01

    This study tried to ascertain (1) the accuracy of synovial fluid white blood cell count and polymorphonucleate percentage in the diagnosis of periprosthetic hip and knee infections, (2) which test yielded superior test performance, and (3) the influence on diagnostic accuracy of study characteristics such as patient number, study design, study level, anatomic site, and threshold value. A systematic search was conducted including papers assessing more effective cutoffs for synovial fluid tests, having comparative design, evaluating an exclusive cohort of hip or knee prostheses, including a clear definition of infected cases, and reporting sufficient data for the calculation of true-positive, false-positive, false-negative, and true-negative. A total of 375 articles were collected and, given the inclusion criteria, ten manuscripts were included. These studies assessed 1155 hip prostheses (276 infected cases) and 1235 knee prostheses (401 infected cases). The specificity of synovial fluid white blood cell count was significantly increased by using the threshold value ≥ 3000 cell/μL (p = 0.006); the sensitivity of polymorphonucleate percentage was significantly higher in detecting knee infections (p = 0.034). Both tests had a high specificity and sensitivity in detecting periprosthetic joint infections, and no clear superiority of one over the other existed. Furthermore, cutoff and anatomic site significantly influenced synovial fluid white blood cell count and polymorphonucleate percentage, respectively. Synovial fluid analysis is adequate in differentiating patients with periprosthetic hip and knee infections. Our data confirms international guidelines suggesting the use of 3000 cell/μL as cutoff threshold for synovial fluid white blood cell count. Since an anatomic site effect has been demonstrated, the goal of future studies will be to identify different cutoffs for hip and knee prostheses.

  6. [External lumbar drainage with volumetric continuing infusion pump in patients with cerebrospinal fluid leak. A case series].

    PubMed

    Manso Melgosa, Ana Belén; García Gutiérrez, Helena; Fernández Porras, Mónica; Castrillo Manero, Ana Berta; Pérez Marijuán, Belén

    To describe the incidence and complications arising in a number of cases of patients with cerebrospinal fluid leak treated by external lumbar drainage with infusion pump (IP) volumetric continuous from 2001 to 2014. Quantify cerebrospinal fluid leak closed by lumbar drainage with IP. Retrospective descriptive case series study. patients undergoing transsphenoidal pituitary surgery, Chiari surgery and laminectomy, that developed postoperative cerebrospinal fluid leak treated with continuous external lumbar drainage by IP. age, sex, type of intervention, variables related to the practice of the pump and complications. Average and medians were calculated for quantitative variables, frequencies and percentages for qualitative. Sample: 11 subjects. Incidence in running IP: disconnection, occlusion and acoustic alarm activation. Most frequently complication is headache; a case of pneumocephalus. The small number of subjects and the heterogeneity of these do not allow for comparison or establishing associations between variables. The resolution of the cerebrospinal fluid leak with continuous IP is lower in this study than others, and may be influenced by the small number of subjects. It should be noted the frequent activation of the pump alarm for no apparent cause. Protocol would be developed for preparing the IP team to reduce the acoustic alarm activation, and would make a prospective multicenter study. Copyright © 2016 Elsevier España, S.L.U. All rights reserved.

  7. Prenatal diagnosis of Bartter syndrome: amniotic fluid aldosterone.

    PubMed

    Rachid, Myriam L; Dreux, Sophie; Pean de Ponfilly, Gauthier; Vargas-Poussou, Rosa; Czerkiewicz, Isabelle; Chevenne, Didier; Oury, Jean-François; Deschênes, Georges; Muller, Françoise

    2016-01-01

    Bartter syndrome is a severe inherited tubulopathy characterized by postnatal salt wasting, severe polyuria, dehydration, failure to thrive and secondary hyperaldosteronism. Prenatally, the disease is usually discovered following the onset of severe polyhydramnios in the second trimester. We studied amniotic fluid aldosterone concentration in Bartter syndrome and in controls. Amniotic fluid aldosterone was assayed by radioimmunoassay. We undertook a retrospective case-control study based on 36 cases of prenatally suspected and postnatally confirmed Bartter syndrome (22 with identified mutations): and 72 gestational age matched controls presenting with polyhydramnios and 72 without polyhydramnios. Amniotic fluid aldosterone was compared between the three groups. The median amniotic fluid aldosterone concentration in the Bartter syndrome group (90 pg/mL) was not different from that in the controls with polyhydramnios (90 pg/mL, P = 0.33) or without polyhydramnios (87 pg/mL, P = 0.41). Amniotic fluid aldosterone assay cannot be used for prenatal diagnosis of Bartter syndrome. © 2015 John Wiley & Sons, Ltd. © 2015 John Wiley & Sons, Ltd.

  8. Detection of malignancy in body fluids: a comparison of the hematology and cytology laboratories.

    PubMed

    Jerz, Jaclyn L; Donohue, Rachel E; Mody, Rayomond R; Schwartz, Mary R; Mody, Dina R; Zieske, Arthur W

    2014-05-01

    Body fluids submitted to the hematology laboratory for cell counts may also be examined for the presence of malignancy. Previous studies evaluating the hematology laboratory's performance at detecting malignancy in body fluids have reached conflicting conclusions. To investigate the hematology laboratory's ability to detect malignancy in body fluids by comparison with cytology. Retrospective analysis of 414 body fluid samples during an 18-month period, with introduction of new quality assurance measures after the first 210 cases. If no concurrent cytology was ordered, results were compared with recent previous and/or subsequent cytologic, histologic, or flow cytometric diagnoses. Of the initial 210 cases, the hematology laboratory detected 3 of 13 malignancies diagnosed by concurrent cytology (23% sensitivity), with no false-positives (100% specificity). Malignancy was not identified on retrospective review of the hematology slides in the 10 discrepant cases. After the initial study, educational sessions on morphology for the medical technologists and a more thorough hematology-cytology correlation policy were implemented. The subsequent 204 hematology laboratory cases had increased sensitivity for the detection of malignancy (60%; 6 of 10). Definitive features of malignancy were seen in only one discrepant hematology laboratory slide on retrospective review. This case had not been flagged for hematopathologist review. None of the discrepancies before or after implementation of the additional quality assurance measures impacted patient care. Body fluid processing by the hematology laboratory is not optimized for the detection of malignancy. Concurrent cytologic examination is critical for the detection of malignancy, and needs to be considered as cost-saving measures are increasingly implemented.

  9. Biochemical markers of trisomy 21 in amniotic fluid.

    PubMed

    Spencer, K; Muller, F; Aitken, D A

    1997-01-01

    In a study of amniotic fluid from 91 Down's syndrome cases and 240 controls, we have shown that the median values of four biochemical markers (AFP, total hCG, free beta hCG, and unconjugated oestriol) in the amniotic fluid of pregnancies affected by Down's syndrome on the whole reflect those observed in the maternal serum of affected cases. The median MOM for AFP was lower than average (0.56), as was that for unconjugated oestriol (0.55), whilst those for total hCG (1.82) and free beta hCG (2.10) were increased on average. The width of the distribution of marker levels in amniotic fluid is similar to that in serum for free beta hCG and total hCG but between 1.5 and 2 times wider for unconjugated oestriol and AFP. Analysis of data by fetal sex showed a significantly higher median MOM in female control cases compared with male controls for the analytes free beta hCG, total hCG, and unconjugated oestriol, but not for AFP. Amongst the Down's syndrome cases, this trend was not statistically significant and we cannot confirm a previous study which reported that elevated levels of amniotic fluid total and free beta hCG were associated only with female fetuses.

  10. Retrospective Case Study in Killdeer, North Dakota

    EPA Pesticide Factsheets

    This study site was chosen at the request of the state to specifically examine any water resource impacts from a well blowout in September 2010 that resulted in an uncontrolled release of hydraulic fracturing fluids and formation fluids.

  11. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ely, J.W.; Brown, T.D.; Reed, S.D.

    A common trend in our industry is to minimize gel concentrations and utilize the lowest viscosity fluid available to place proppant. Barrett Resources Corporation has found, for lenticular microdarcy formations, that one of the keys for success is enhanced proppant transport. This is achieved incorporating stable gels which maintain greater than 1000 cps viscosity at bottomhole static temperature for the duration of the treatment. An extensive case study has been completed, involving over 500 fracture stimulation treatments in more than 175 wells, that illustrates the poor results achieved in the Williams Formation of the Mesaverde Group using low viscosity fluids.more » Low viscosity fluids invariably exhibit poor proppant transport. The statistical study shows that larger treatments utilizing {open_quotes}perfect proppant transport{close_quotes} fluids gain superior results. Based upon the case study, 100% economic success has been achieved upon incorporating stable fluids containing delayed breakers, reducing pad volumes to less than 5% of total job size, and minimizing echelon fractures while implementing a limited entry stimulation technique.« less

  12. Gastric fluid versus amniotic fluid analysis for the identification of intra-amniotic infection due to Ureaplasma species

    PubMed Central

    Kim, Sun Min; Romero, Roberto; Lee, JoonHo; Chaemsaithong, Piya; Docheva, Nikolina; Yoon, Bo Hyun

    2017-01-01

    Objective Early neonatal sepsis is often due to intra-amniotic infection. The stomach of the neonate contains fluid swallowed before and during delivery. The presence of bacteria as well as neutrophils detected by culture or Gram stain in the gastric fluid during the first day of life is suggestive of exposure to bacteria or inflammation. We undertook this study to determine the relationship between gastric fluid analysis and amniotic fluid obtained by transabdominal amniocentesis in the detection of Ureaplasma species, the most frequent microorganisms responsible for intra-amniotic infection. Materials and Methods The study population consisted of 100 singleton pregnant women who delivered preterm neonates (<35weeks) within 7 days of amniocentesis. Gastric fluid of newborns was obtained by nasogastric intubation on the day of birth. Amniotic fluid and gastric fluid were cultured for genital Mycoplasmas and polymerase chain reaction (PCR) for Ureaplasma species was performed. Intra-amniotic inflammation was defined as an elevated amniotic fluid matrix metalloproteinase-8 concentration (> 23ng/mL). Results 1) Ureaplasma species were detected by culture or PCR in 18% (18/100) of amniotic fluid samples and in 5% (5/100) of gastric fluid samples; 2) among the amniotic fluid cases positive for Ureaplasma species, these microorganisms were identified in 27.8% (5/18) of gastric fluid samples; 3) none of the cases negative for Ureaplasma species in the amniotic fluid were found to be positive for these microorganisms in the gastric fluid; 4) patients with amniotic fluid positive for Ureaplasma species but with gastric fluid negative for these microorganisms had a significantly higher rate of intra-amniotic inflammation, acute histologic chorioamnionitis, and neonatal death than those with both amniotic fluid and gastric fluid negative for Ureaplasma species; and 5) no significant differences were observed in the rate of intra-amniotic inflammation, acute histologic chorioamnionitis, and neonatal death between patients with amniotic fluid positive for Ureaplasma species but with gastric fluid negative for these microorganisms and those with both amniotic fluid and gastric fluid positive for Ureaplasma species. Conclusions Gastric fluid analysis has 100% specificity in the identification of intra-amniotic infection with Ureaplasma species. However the detection of Ureaplasma species by culture or PCR in the gastric fluid of neonates at birth did not identify these microorganisms in two-thirds of cases with microbial invasion of the amniotic cavity. Thus, amniotic fluid analysis is superior to that of gastric fluid in the identification of intra-amniotic infection. PMID:26631980

  13. Gastric fluid versus amniotic fluid analysis for the identification of intra-amniotic infection due to Ureaplasma species.

    PubMed

    Kim, Sun Min; Romero, Roberto; Lee, JoonHo; Chaemsaithong, Piya; Docheva, Nikolina; Yoon, Bo Hyun

    2016-01-01

    Early neonatal sepsis is often due to intra-amniotic infection. The stomach of the neonate contains fluid swallowed before and during delivery. The presence of bacteria as well as neutrophils detected by culture or Gram stain of the gastric fluid during the first day of life is suggestive of exposure to bacteria or inflammation. We undertook this study to determine the relationship between gastric fluid analysis and amniotic fluid obtained by transabdominal amniocentesis in the detection of Ureaplasma species, the most frequent microorganisms responsible for intra-amniotic infection. The study population consisted of 100 singleton pregnant women who delivered preterm neonates (<35 weeks) within 7 days of amniocentesis. Gastric fluid of newborns was obtained by nasogastric intubation on the day of birth. Amniotic fluid and gastric fluid were cultured for genital Mycoplasmas, and polymerase chain reaction (PCR) for Ureaplasma species was performed. Intra-amniotic inflammation was defined as an elevated amniotic fluid matrix metalloproteinase-8 concentration (>23 ng/mL). (1) Ureaplasma species were detected by culture or PCR in 18% (18/100) of amniotic fluid samples and in 5% (5/100) of gastric fluid samples; (2) among the amniotic fluid cases positive for Ureaplasma species, these microorganisms were identified in 27.8% (5/18) of gastric fluid samples; (3) none of the cases negative for Ureaplasma species in the amniotic fluid were found to be positive for these microorganisms in the gastric fluid; (4) patients with amniotic fluid positive for Ureaplasma species but with gastric fluid negative for these microorganisms had a significantly higher rate of intra-amniotic inflammation, acute histologic chorioamnionitis, and neonatal death than those with both amniotic fluid and gastric fluid negative for Ureaplasma species; and (5) no significant differences were observed in the rate of intra-amniotic inflammation, acute histologic chorioamnionitis, and neonatal death between patients with amniotic fluid positive for Ureaplasma species but with gastric fluid negative for these microorganisms and those with both amniotic fluid and gastric fluid positive for Ureaplasma species. Gastric fluid analysis has 100% specificity in the identification of intra-amniotic infection with Ureaplasma species. However, the detection of Ureaplasma species by culture or PCR in the gastric fluid of neonates at birth did not identify these microorganisms in two-thirds of cases with microbial invasion of the amniotic cavity. Thus, amniotic fluid analysis is superior to that of gastric fluid in the identification of intra-amniotic infection.

  14. Unsteady magnetohydrodynamic free convection flow of a second grade fluid in a porous medium with ramped wall temperature.

    PubMed

    Samiulhaq; Ahmad, Sohail; Vieru, Dumitru; Khan, Ilyas; Shafie, Sharidan

    2014-01-01

    Magnetic field influence on unsteady free convection flow of a second grade fluid near an infinite vertical flat plate with ramped wall temperature embedded in a porous medium is studied. It has been observed that magnitude of velocity as well as skin friction in case of ramped temperature is quite less than the isothermal temperature. Some special cases namely: (i) second grade fluid in the absence of magnetic field and porous medium and (ii) Newtonian fluid in the presence of magnetic field and porous medium, performing the same motion are obtained. Finally, the influence of various parameters is graphically shown.

  15. Thermal shaft effects on load-carrying capacity of a fully coupled, variable-properties cryogenic journal bearing

    NASA Technical Reports Server (NTRS)

    Braun, M. J.; Wheeler, R. L., III; Hendricks, R. C.

    1986-01-01

    The purpose of this work was to perform a rather complete analysis for a cryogenic (oxygen) journal bearing. The Reynolds equation required coupling and simultaneous solution with the fluid energy equation. To correctly account for the changes in the fluid viscosity, the fluid energy equation was coupled with the shaft and bearing heat conduction energy equations. The effects of pressure and temperature on the density, viscosity, and load-carrying capacity were further discussed as analysis parameters, with respect to relative eccentricity and the angular velocity. The isothermal fluid case and the adiabatic fluid case represented the limiting boundaries. The discussion was further extrapolated to study the Sommerfeld number dependency on the fluid Nusselt number and its consequence on possible total loss of load-carrying capacity and/or seizure (catastrophic failure).

  16. Acute gouty bursitis: report of 15 cases.

    PubMed Central

    Canoso, J J; Yood, R A

    1979-01-01

    Fifteen cases of acute gouty bursitis were seen among 136 crystal-proved cases of gout. Bursal aspirate yielded yellow or pink fluid in 10, chalky white fluid in 1, and a small amount of bloody fluid in 4. Monosodium urate crystals were present in all. Bursal fluid leucocyte counts averaged 2.9 X 10(9)/1 compared with synovial fluid leucocyte counts that averaged 25.5 X 10(9)/1 in cases of articular gout (P less than 0.05). Gouty, septic, and idiopathic (traumatic) bursitis share clinical features, and detailed bursal fluid analysis is crucial for diagnosis. PMID:496446

  17. Comparative study of Eyring and Carreau fluids in a suspension of dust and nickel nanoparticles with variable conductivity

    NASA Astrophysics Data System (ADS)

    Mamatha Upadhya, S.; Mahesha; Raju, C. S. K.

    2018-04-01

    A theoretical analysis is carried out to investigate the magnetohydrodynamic unsteady flow of Eyring-Powell and Carreau non-Newtonian fluids in a suspension of dust and nickel nanoparticles by considering variable thermal conductivity and thermal radiation. Dispersion of nickel nanoparticles in dusty fluids finds applications in heat exchanger systems, rechargeable batteries, chemical catalysts, metallurgy, conducting paints, magnetic recording media, drug delivery, nanofibers, textiles, etc. The initially arising set of physical governing partial differential equations is transformed to ordinary differential equations (ODEs) with the aid of similarity transformations. Consequentially, the nonlinear ODEs are solved numerically through the Runge-Kutta Fehlberg scheme (RKFS). The computational results for non-dimensional temperature and velocity profiles are presented through graphs. Furthermore, the numerical values of friction factor and heat transfer rate are tabulated numerically for the unsteady and steady cases of the Eyring and Carreau fluid cases and of the dusty non-Newtonian (φ=0) and the dusty non-Newtonian nanofluid (φ≠ 0) cases of the unsteady flow. We also validated the present results with previous published studies and found them to be highly satisfactory. The formulated model reveals that the rate of heat transfer is higher in the mixture of the nickel + Eyring-Powell case compared to the nickel + Carreau case. From this we can highlight that, depending on the industrial appliances, we can use heating or cooling processes for Eyring and Carreau fluids, respectively.

  18. Glossosoma nigrior (Trichoptera: Glossosomatidae) respiration in moving fluid.

    PubMed

    Morris, Mark W L; Hondzo, Miki

    2013-08-15

    Laboratory measurements of dissolved oxygen (DO) uptake by Glossosoma nigrior Banks were conducted in a sealed, recirculating flume under variable fluid flow velocities. Measurements were performed in similar water temperatures, DO concentrations and fluid flow velocities to field conditions in the stream where the larvae were obtained. Total oxygen uptake by both cased larvae and corresponding cases without larvae were quantified. An increased fluid flow velocity corresponded to an increased larval DO uptake rate. Oxygen uptake by the larval cases alone was not as sensitive to changes in the Peclet (Pe) number, the dimensionless ratio of advective to diffusive DO transport, as uptake by larvae themselves. The flux of DO to larvae and their cases was up to seven times larger in a moving fluid in comparison to non-moving fluid conditions in the proximity of larvae for 087, larvae typically remained in their cases. This indicates that oxygen delivery to the larvae at low Pe is insufficient to satisfy the respiratory demands of cased larvae.

  19. [Fluid therapy in acute pancreatitis].

    PubMed

    de-Madaria, Enrique

    2013-12-01

    Severe acute pancreatitis (AP) is associated with an increased need for fluids due to fluid sequestration and, in the most severe cases, with decreased peripheral vascular tone. For several decades, clinical practice guidelines have recommended aggressive fluid therapy to improve the prognosis of AP. This recommendation is based on theoretical models, animal studies, and retrospective studies in humans. Recent studies suggest that aggressive fluid administration in all patients with AP could have a neutral or harmful effect. Fluid therapy based on Ringer's lactate could improve the course of the disease, although further studies are needed to confirm this possibility. Most patients with AP do not require invasive monitoring of hemodynamic parameters to guide fluid therapy administration. Moreover, the ability of these parameters to improve prognosis has not been demonstrated. Copyright © 2013 Elsevier España, S.L. and AEEH y AEG. All rights reserved.

  20. Numerical Temperature And Fluid-Flow Modelling For The Topographic Effects On Hydrothermal Circulation; A case study in Lucy Strike Vent Field

    NASA Astrophysics Data System (ADS)

    Erçetin, Engin; Düşünür Doǧan, Doǧa

    2017-04-01

    The aim of the study is to present a numerical temperature and fluid-flow modelling for the topographic effects on hydrothermal circulation. Bathymetry can create a major disturbance on fluid flow pattern. ANSYS Fluent Computational fluid dynamics software is used for simulations. Coupled fluid flow and temperature quations are solved using a 2-Dimensional control volume finite difference approach. Darcy's law is assumed to hold, the fluid is considered to be anormal Boussinesq incompressible fluid neglecting inertial effects. Several topographic models were simulated and both temperature and fluid flow calculations obtained for this study. The preliminary simulations examine the effect of a ingle bathymetric high on a single plume and the secondary study of simulations investigates the effect of multiple bathymetric highs on multiple plume. The simulations were also performed for the slow spreading Lucky Strike segment along the Mid-Atlantic Ridge (MAR), one of the best studied regions along the MAR, where a 3.4 km deep magma chamber extending 6 km along-axis is found at its center. The Lucky Strike segment displays a transitional morphology between that of the FAMOUS - North FAMOUS segments, which are characterized by well-developed axial valleys typical of slow-spreading segments, and that of the Menez Gwen segment, characterized by an axial high at the segment center. Lucky Strike Segment hosts a central volcano and active vent field located at the segment center and thus constitutes an excellent case study to simulate the effects of bathymetry on fluid flow. Results demonstrate that bathymetric relief has an important influence on hydrothermal flow. Subsurface pressure alterations can be formed by bathymetric highs, for this reason, bathymetric relief ought to be considered while simulating hydrothermal circulation systems. Results of this study suggest the dominant effect of bathymetric highs on fluid flow pattern and Darcy velocities will be presented. Keywords: Hydrothermal Circulation, Lucky Strike, Bathymetry - Topography, Vent Location, Fluid Flow, Numerical Modelling

  1. Positive FAST without hemoperitoneum due to fluid resuscitation in blunt trauma.

    PubMed

    Slutzman, Jonathan E; Arvold, Lisa A; Rempell, Joshua S; Stone, Michael B; Kimberly, Heidi H

    2014-10-01

    The focused assessment with sonography in trauma (FAST) examination is an important screening tool in the evaluation of blunt trauma patients. To describe a case of a hemodynamically unstable polytrauma patient with positive FAST due to fluid resuscitation after blunt trauma. We describe a case of a hemodynamically unstable polytrauma patient who underwent massive volume resuscitation prior to transfer from a community hospital to a trauma center. On arrival at the receiving institution, the FAST examination was positive for free intraperitoneal fluid, but no hemoperitoneum or significant intra-abdominal injuries were found during laparotomy. In this case, it is postulated that transudative intraperitoneal fluid secondary to massive volume resuscitation resulted in a positive FAST examination. This case highlights potential issues specific to resuscitated trauma patients with prolonged transport times. Further study is likely needed to assess what changes, if any, should be made in algorithms to address the effect of prior resuscitative efforts on the test characteristics of the FAST examination. Copyright © 2014 Elsevier Inc. All rights reserved.

  2. ADMiER-ing thin but complex fluids

    NASA Astrophysics Data System (ADS)

    McDonnell, Amarin G.; Bhattacharjee, Pradipto K.; Pan, Sharadwata; Hill, David; Danquah, Michael K.; Friend, James R.; Yeo, Leslie Y.; Prabhakar, Ranganathan

    2011-12-01

    The Acoustics Driven Microfluidic Extensional Rheometer (ADMiER) utilises micro litre volumes of liquid, with viscosities as low as that of water, to create valid and observable extensional flows, liquid bridges that pinch off due to capillary forces in this case. ADMiER allows the study fluids that have been beyond conventional methods and also study more subtle fluid properties. We can observe polymeric fluids with solvent viscosities far below those previously testable, accentuating elastic effects. Also, it has enabled the testing of aqueous solutions of living motile particles, which significantly change fluid properties, opening up the potential for diagnostic applications.

  3. Association Between Fluid Balance and Outcomes in Critically Ill Children: A Systematic Review and Meta-analysis.

    PubMed

    Alobaidi, Rashid; Morgan, Catherine; Basu, Rajit K; Stenson, Erin; Featherstone, Robin; Majumdar, Sumit R; Bagshaw, Sean M

    2018-03-01

    After initial resuscitation, critically ill children may accumulate fluid and develop fluid overload. Accruing evidence suggests that fluid overload contributes to greater complexity of care and worse outcomes. To describe the methods to measure fluid balance, define fluid overload, and evaluate the association between fluid balance and outcomes in critically ill children. Systematic search of MEDLINE, EMBASE, Cochrane Library, trial registries, and selected gray literature from inception to March 2017. Studies of children admitted to pediatric intensive care units that described fluid balance or fluid overload and reported outcomes of interest were included. No language restrictions were applied. All stages were conducted independently by 2 reviewers. Data extracted included study characteristics, population, fluid metrics, and outcomes. Risk of bias was assessed using the Newcastle-Ottawa Scale. Narrative description of fluid assessment methods and fluid overload definitions was done. When feasible, pooled analyses were performed using random-effects models. Mortality was the primary outcome. Secondary outcomes included treatment intensity, organ failure, and resource use. A total of 44 studies (7507 children) were included in this systematic review and meta-analysis. Of those, 27 (61%) were retrospective cohort studies, 13 (30%) were prospective cohort studies, 3 (7%) were case-control studies, and 1 study (2%) was a secondary analysis of a randomized trial. The proportion of children with fluid overload varied by case mix and fluid overload definition (median, 33%; range, 10%-83%). Fluid overload, however defined, was associated with increased in-hospital mortality (17 studies [n = 2853]; odds ratio [OR], 4.34 [95% CI, 3.01-6.26]; I2 = 61%). Survivors had lower percentage fluid overload than nonsurvivors (22 studies [n = 2848]; mean difference, -5.62 [95% CI, -7.28 to -3.97]; I2 = 76%). After adjustment for illness severity, there was a 6% increase in odds of mortality for every 1% increase in percentage fluid overload (11 studies [n = 3200]; adjusted OR, 1.06 [95% CI, 1.03-1.10]; I2 = 66%). Fluid overload was associated with increased risk for prolonged mechanical ventilation (>48 hours) (3 studies [n = 631]; OR, 2.14 [95% CI, 1.25-3.66]; I2 = 0%) and acute kidney injury (7 studies [n = 1833]; OR, 2.36 [95% CI, 1.27-4.38]; I2 = 78%). Fluid overload is common and is associated with substantial morbidity and mortality in critically ill children. Additional research should now ideally focus on interventions aimed to mitigate the potential for harm associated with fluid overload.

  4. Scaling of seismicity induced by nonlinear fluid-rock interaction after an injection stop

    NASA Astrophysics Data System (ADS)

    Johann, L.; Dinske, C.; Shapiro, S. A.

    2016-11-01

    Fluid injections into unconventional reservoirs, performed for fluid-mobility enhancement, are accompanied by microseismic activity also after the injection. Previous studies revealed that the triggering of seismic events can be effectively described by nonlinear diffusion of pore fluid pressure perturbations where the hydraulic diffusivity becomes pressure dependent. The spatiotemporal distribution of postinjection-induced microseismicity has two important features: the triggering front, corresponding to early and distant events, and the back front, representing the time-dependent spatial envelope of the growing seismic quiescence zone. Here for the first time, we describe analytically the temporal behavior of these two fronts after the injection stop in the case of nonlinear pore fluid pressure diffusion. We propose a scaling law for the fronts and show that they are sensitive to the degree of nonlinearity and to the Euclidean dimension of the dominant growth of seismicity clouds. To validate the theoretical finding, we numerically model nonlinear pore fluid pressure diffusion and generate synthetic catalogs of seismicity. Additionally, we apply the new scaling relation to several case studies of injection-induced seismicity. The derived scaling laws describe well synthetic and real data.

  5. The Etiology, Incidence, and Impact of Preservation Fluid Contamination during Liver Transplantation

    PubMed Central

    Lladó, Laura; Vila, Marina; Baliellas, Carme; Tubau, Fe; Sabé, Núria; Fabregat, Joan; Carratalà, Jordi

    2016-01-01

    The role of contaminated preservation fluid in the development of infection after liver transplantation has not been fully elucidated. To assess the incidence and etiology of contaminated preservation fluid and determine its impact on the subsequent development of infection after liver transplantation, we prospectively studied 50 consecutive liver transplants, and cultured the following samples in each instance: preservation fluid (immediately before and at the end of the back-table procedure, and just before implantation), blood, and bile from the donor, and ascitic fluid from the recipient. When any culture was positive, blood cultures were obtained and targeted antimicrobial therapy was started. We found that the incidence of contaminated preservation fluid was 92% (46 of 50 cases of liver transplantation per year), but only 28% (14/50) were contaminated by recognized pathogens. Blood and bile cultures from the donor were positive in 28% and 6% respectively, whereas ascitic fluid was positive in 22%. The most frequently isolated microorganisms were coagulase-negative staphylococci. In nine cases, the microorganisms isolated from the preservation fluid concurred with those grown from the donor blood cultures, and in one case, the isolate matched with the one obtained from bile culture. No liver transplant recipient developed an infection due to the transmission of an organism isolated from the preservation fluid. Our findings indicate that contamination of the preservation fluid is frequent in liver transplantation, and it is mainly caused by saprophytic skin flora. Transmission of infection is low, particularly among those recipients given targeted antimicrobial treatment for organisms isolated in the preservation fluid. PMID:27513941

  6. The Etiology, Incidence, and Impact of Preservation Fluid Contamination during Liver Transplantation.

    PubMed

    Oriol, Isabel; Lladó, Laura; Vila, Marina; Baliellas, Carme; Tubau, Fe; Sabé, Núria; Fabregat, Joan; Carratalà, Jordi

    2016-01-01

    The role of contaminated preservation fluid in the development of infection after liver transplantation has not been fully elucidated. To assess the incidence and etiology of contaminated preservation fluid and determine its impact on the subsequent development of infection after liver transplantation, we prospectively studied 50 consecutive liver transplants, and cultured the following samples in each instance: preservation fluid (immediately before and at the end of the back-table procedure, and just before implantation), blood, and bile from the donor, and ascitic fluid from the recipient. When any culture was positive, blood cultures were obtained and targeted antimicrobial therapy was started. We found that the incidence of contaminated preservation fluid was 92% (46 of 50 cases of liver transplantation per year), but only 28% (14/50) were contaminated by recognized pathogens. Blood and bile cultures from the donor were positive in 28% and 6% respectively, whereas ascitic fluid was positive in 22%. The most frequently isolated microorganisms were coagulase-negative staphylococci. In nine cases, the microorganisms isolated from the preservation fluid concurred with those grown from the donor blood cultures, and in one case, the isolate matched with the one obtained from bile culture. No liver transplant recipient developed an infection due to the transmission of an organism isolated from the preservation fluid. Our findings indicate that contamination of the preservation fluid is frequent in liver transplantation, and it is mainly caused by saprophytic skin flora. Transmission of infection is low, particularly among those recipients given targeted antimicrobial treatment for organisms isolated in the preservation fluid.

  7. [Perioperative fluid therapy for surgical patients with chronic kidney disease].

    PubMed

    Iijima, Takehiko

    2013-11-01

    Chronic kidney disease (CKD) often accompanies cardiovascular complications, causing postoperative morbidity and even mortality. Since fluid and electrolyte homeostasis is deregulated in CKD patients, fluid therapy itself may cause postoperative morbidity. Recent studies have shown that forced diuresis through fluid overload offers no renoprotective effect and instead has harmful consequences. Fluid overload should be avoided, and the volume load should be used as the rationale for controlling hemodynamics. The emerging concept of a "zero-fluid balance policy" may be beneficial even for CKD patients. Hydroxyethylstarch might not be preferentially used for CKD patients. Hydroxyethylstarch is not contraindicated for CKD patients except in cases with long-term accumulation caused by increased vascular permeability, such as cases with sepsis, as long as an efficient volume expansion is beneficial to the patient. The regulation of renal function through the endocrine system (i.e., renin-angiotensin-aldosterone and vasopressin) is a key target for protecting the kidney in CKD. The recent development of a receptor blocker targeting these endocrine systems may be beneficial for correcting the fluid balance caused by excess intraoperative fluid therapy. The main issue for fluid therapy in surgical CKD patients may not be the quantity of fluid, but rational intervention affecting the endocrine system.

  8. Prenatal diagnosis of congenital toxoplasmosis: comparative value of fetal blood and amniotic fluid using serological techniques and cultures.

    PubMed

    Fricker-Hidalgo, H; Pelloux, H; Muet, F; Racinet, C; Bost, M; Goullier-Fleuret, A; Ambroise-Thomas, P

    1997-09-01

    The prenatal diagnosis of congenital toxoplasmosis is mainly based on biological tests performed on fetal blood and amniotic fluid. We studied the performance of neonatal diagnosis procedures and the results of fetal blood and amniotic fluid analysis. Of 127 women who contracted toxoplasmosis and underwent prenatal diagnosis, the postnatal serological follow-up was long enough to definitively diagnose congenital toxoplasmosis in 19 cases and to exclude it in 27 cases. Prenatal diagnosis allowed the detection of 94.7 per cent (18/19) of the infected fetuses. The sensitivities of tests in amniotic fluid and fetal blood were equivalent, 88.2 per cent (15/17) and 87.5 per cent (14/16), respectively. In fetal blood, biological techniques were positive in 12/16 cases and in 2/16 cases, serological tests were the only positive sign. The specificities of tests in amniotic fluid and fetal blood were respectively 100 per cent (23/23) and 86.3 per cent (19/22) (three false-positive serological results). These results, added to the lower morbidity of amniocentesis compared with cordocentesis, might lead to cordocentesis being abandoned in the prenatal diagnosis of congenital toxoplasmosis.

  9. The wavefield of acoustic logging in a cased hole with a single casing—Part II: a dipole tool

    NASA Astrophysics Data System (ADS)

    Wang, Hua; Fehler, Michael

    2018-02-01

    The acoustic method, being the most effective method for cement bond evaluation, has been used by industry for more than a half century. However, the methods currently used are almost always focused on the first arrival (especially for sonic logging), which has limitations. We use a 3-D finite-difference method to numerically simulate the wavefields from a dipole source in a single-cased hole with different cement conditions. By using wavefield snapshots and dispersion curves, we interpret the characteristics of the modes in the models. We investigate the effect of source frequency, the thickness and location of fluid columns on different modes. The dipole wavefield in a single-cased hole consists of a leaky P (for frequency >10 kHz) from formation, formation flexural, and also some casing modes. Depending on the mode, their behaviour is sometimes sensitive to the existence of fluid between the cement and formation and sometimes sensitive to the existence of fluid between the casing and cement. The formation S velocity can be obtained from the formation flexural mode at low frequency. However, interference from high-order casing modes makes the leaky P invisible and P velocity determination difficult when the casing is not well cemented. The dispersion curve of the formation flexural mode is sensitive to the fluid thickness when fluid exists only at the interface between casing and cement. The fundamental casing dipole mode is only sensitive to the total fluid thickness in the annulus between casing and formation. Either the arrival time or amplitude of the high-order casing dipole mode is sensitive to the fluid column when the fluid column is next to the casing. We provide a table that summarizes the ability of different modes to detect fluid columns between various layers of casing, cement and formation. Based on the results, we suggest a data processing flow for field application, which will highly improve cement evaluation.

  10. High-speed cylindrical collapse of two perfect fluids

    NASA Astrophysics Data System (ADS)

    Sharif, M.; Ahmad, Zahid

    2007-09-01

    In this paper, the study of the gravitational collapse of cylindrically distributed two perfect fluid system has been carried out. It is assumed that the collapsing speeds of the two fluids are very large. We explore this condition by using the high-speed approximation scheme. There arise two cases, i.e., bounded and vanishing of the ratios of the pressures with densities of two fluids given by c s , d s . It is shown that the high-speed approximation scheme breaks down by non-zero pressures p 1, p 2 when c s , d s are bounded below by some positive constants. The failure of the high-speed approximation scheme at some particular time of the gravitational collapse suggests the uncertainty on the evolution at and after this time. In the bounded case, the naked singularity formation seems to be impossible for the cylindrical two perfect fluids. For the vanishing case, if a linear equation of state is used, the high-speed collapse does not break down by the effects of the pressures and consequently a naked singularity forms. This work provides the generalisation of the results already given by Nakao and Morisawa (Prog Theor Phys 113:73, 2005) for the perfect fluid.

  11. Classical and quantum cosmology with two perfect fluids: stiff matter and radiation

    NASA Astrophysics Data System (ADS)

    Alvarenga, F. G.; Fracalossi, R.; Freitas, R. C.; Gonçalves, S. V. B.

    2017-11-01

    In this work the homogeneous and isotropic Universe of Friedmann-Robertson-Walker is studied in the presence of two fluids: stiff matter and radiation described by the Schutz's formalism. We obtain to the classic case the behaviour of the scale factor of the universe. For the quantum case the wave packets are constructed and the wave function of the universe is found.

  12. Supercritical Fluid Extraction versus Traditional Solvent Extraction of Caffeine from Tea Leaves: A Laboratory-Based Case Study for an Organic Chemistry Course

    ERIC Educational Resources Information Center

    Schaber, Peter M.; Larkin, Judith E.; Pines, Harvey A.; Berchou, Kelly; Wierchowski, Elizabeth; Marconi, Andrew; Suriani, Allison

    2012-01-01

    In this case-based laboratory, an instrument sales person attempts to convince an analysis laboratory of the virtues of supercritical fluid extraction (SFE). The sales person deals directly with the laboratory technicians who will make the decision. Arrangements are made to have SFE instrumentation brought into the laboratory for a comparative…

  13. Mass-conserved volumetric lattice Boltzmann method for complex flows with willfully moving boundaries.

    PubMed

    Yu, Huidan; Chen, Xi; Wang, Zhiqiang; Deep, Debanjan; Lima, Everton; Zhao, Ye; Teague, Shawn D

    2014-06-01

    In this paper, we develop a mass-conserved volumetric lattice Boltzmann method (MCVLBM) for numerically solving fluid dynamics with willfully moving arbitrary boundaries. In MCVLBM, fluid particles are uniformly distributed in lattice cells and the lattice Boltzmann equations deal with the time evolution of the particle distribution function. By introducing a volumetric parameter P(x,y,z,t) defined as the occupation of solid volume in the cell, we distinguish three types of lattice cells in the simulation domain: solid cell (pure solid occupation, P=1), fluid cell (pure fluid occupation, P=0), and boundary cell (partial solid and partial fluid, 0

  14. Fluid inclusion gas chemistry as a potential minerals exploration tool: Case studies from Creede, CO, Jerritt Canyon, NV, Coeur d'Alene district, ID and MT, southern Alaska mesothermal veins, and mid-continent MVT's

    USGS Publications Warehouse

    Landis, G.P.; Hofstra, A.H.

    1991-01-01

    Recent advances in instrumentation now permit quantitative analysis of gas species from individual fluid inclusions. Fluid inclusion gas data can be applied to minerals exploration empirically to establish chemical (gas composition) signatures of the ore fluids, and conceptually through the development of genetic models of ore formation from a framework of integrated geologic, geochemical, and isotopic investigations. Case studies of fluid inclusion gas chemistry from ore deposits representing a spectrum of ore-forming processes and environments are presented to illustrate both the empirical and conceptual approaches. We consider epithermal silver-gold deposits of Creede, Colorado, Carlin-type sediment-hosted disseminated gold deposits of Jerritt Canyon, Nevada, metamorphic silver-base-metal veins of the Coeur d'Alene district, Idaho and Montana, gold-quartz veins in accreted terranes of southern Alaska, and the mid-continent base-metal sulfide deposits of Mississippi Valley-Type (MVT's). Variations in gas chemistry determine the redox state of the ore fluids, provide compositional input for gas geothermometers, characterize ore fluid chemistry (e.g., CH4CO2, H2SSO2, CO2/H2S, organic-rich fluids, gas-rich and gas-poor fluids), identify magmatic, meteoric, metamorphic, shallow and deep basin fluids in ore systems, locate upwelling plumes of magmatic-derived volatiles, zones of boiling and volatile separation, interfaces between contrasting fluids, and important zones of fluid mixing. Present techniques are immediately applicable to exploration programsas empirical studies that monitor fluid inclusion gas threshold concentration levels, presence or absence of certain gases, or changes in gas ratios. We suggest that the greater contribution of fluid inclusion gas analysis is in the integrated and comprehensive chemical dimension that gas data impart to genetic models, and in the exploration concepts based on processes and environments of ore formation derived from these genetic models. ?? 1991.

  15. Density Effects on Post-shock Turbulence Structure

    NASA Astrophysics Data System (ADS)

    Tian, Yifeng; Jaberi, Farhad; Livescu, Daniel; Li, Zhaorui; Michigan State University Collaboration; Los Alamos National Laboratory Collaboration; Texas A&M University-Corpus Christi Collaboration

    2017-11-01

    The effects of density variations due to mixture composition on post-shock turbulence structure are studied using turbulence-resolving shock-capturing simulations. This work extends the canonical Shock-Turbulence Interaction (STI) problem to involve significant variable density effects. The numerical method has been verified using a series of grid and LIA convergence tests, and is used to generate accurate post-shock turbulence data for a detailed flow study. Density effects on post-shock turbulent statistics are shown to be significant, leading to an increased amplification of turbulent kinetic energy (TKE). Eulerian and Lagrangian analyses show that the increase in the post-shock correlation between rotation and strain is weakened in the case with significant density variations (referred to as the ``multi-fluid'' case). Similar to previous single-fluid results and LIA predictions, the shock wave significantly changes the topology of the turbulent structures, exhibiting a symmetrization of the joint PDF of second and third invariant of the deviatoric part of velocity gradient tensor. In the multi-fluid case, this trend is more significant and mainly manifested in the heavy fluid regions. Lagrangian data are also used to study the evolution of turbulence structure away from the shock wave and assess the accuracy of Lagrangian dynamical models.

  16. Inhomogeneous fluid of penetrable-spheres: Application of the random phase approximation

    NASA Astrophysics Data System (ADS)

    Xiang, Yan; Frydel, Derek

    2017-05-01

    The focus of the present work is the application of the random phase approximation (RPA), derived for inhomogeneous fluids [Frydel and Ma, Phys. Rev. E 93, 062112 (2016)], to penetrable-spheres. As penetrable-spheres transform into hard-spheres with increasing interactions, they provide an interesting case for exploring the RPA, its shortcomings, and limitations, the weak- versus the strong-coupling limit. Two scenarios taken up by the present study are a one-component and a two-component fluid with symmetric interactions. In the latter case, the mean-field contributions cancel out and any contributions from particle interactions are accounted for by correlations. The accuracy of the RPA for this case is the result of a somewhat lucky cancellation of errors.

  17. Viscous fingering with partially miscible fluids

    NASA Astrophysics Data System (ADS)

    Fu, Xiaojing; Cueto-Felgueroso, Luis; Juanes, Ruben

    2017-10-01

    Viscous fingering—the fluid-mechanical instability that takes place when a low-viscosity fluid displaces a high-viscosity fluid—has traditionally been studied under either fully miscible or fully immiscible fluid systems. Here we study the impact of partial miscibility (a common occurrence in practice) on the fingering dynamics. Through a careful design of the thermodynamic free energy of a binary mixture, we develop a phase-field model of fluid-fluid displacements in a Hele-Shaw cell for the general case in which the two fluids have limited (but nonzero) solubility into one another. We show, by means of high-resolution numerical simulations, that partial miscibility exerts a powerful control on the degree of fingering: fluid dissolution hinders fingering while fluid exsolution enhances fingering. We also show that, as a result of the interplay between compositional exchange and the hydrodynamic pattern-forming process, stronger fingering promotes the system to approach thermodynamic equilibrium more quickly.

  18. Detecting well casing leaks in Bangladesh using a salt spiking method

    USGS Publications Warehouse

    Stahl, M.O.; Ong, J.B.; Harvey, C.F.; Johnson, C.D.; Badruzzaman, A.B.M.; Tarek, M.H.; VanGeen, A.; Anderson, J.A.; Lane, J.W.

    2014-01-01

    We apply fluid-replacement logging in arsenic-contaminated regions of Bangladesh using a low-cost, down-well fluid conductivity logging tool to detect leaks in the cased section of wells. The fluid-conductivity tool is designed for the developing world: it is lightweight and easily transportable, operable by one person, and can be built for minimal cost. The fluid-replacement test identifies leaking casing by comparison of fluid conductivity logs collected before and after spiking the wellbore with a sodium chloride tracer. Here, we present results of fluid-replacement logging tests from both leaking and non-leaking casing from wells in Araihazar and Munshiganj, Bangladesh, and demonstrate that the low-cost tool produces measurements comparable to those obtained with a standard geophysical logging tool. Finally, we suggest well testing procedures and approaches for preventing casing leaks in Bangladesh and other developing countries.

  19. Detecting well casing leaks in Bangladesh using a salt spiking method.

    PubMed

    Stahl, M O; Ong, J B; Harvey, C F; Johnson, C D; Badruzzaman, A B M; Tarek, M H; van Geen, A; Anderson, J A; Lane, J W

    2014-09-01

    We apply fluid-replacement logging in arsenic-contaminated regions of Bangladesh using a low-cost, down-well fluid conductivity logging tool to detect leaks in the cased section of wells. The fluid-conductivity tool is designed for the developing world: it is lightweight and easily transportable, operable by one person, and can be built for minimal cost. The fluid-replacement test identifies leaking casing by comparison of fluid conductivity logs collected before and after spiking the wellbore with a sodium chloride tracer. Here, we present results of fluid-replacement logging tests from both leaking and non-leaking casing from wells in Araihazar and Munshiganj, Bangladesh, and demonstrate that the low-cost tool produces measurements comparable to those obtained with a standard geophysical logging tool. Finally, we suggest well testing procedures and approaches for preventing casing leaks in Bangladesh and other developing countries. © 2014, National Ground Water Association.

  20. Biofluid mechanics of special organs and the issue of system control. Sixth International Bio-Fluid Mechanics Symposium and Workshop, March 28-30, 2008 Pasadena, California.

    PubMed

    Zamir, Mair; Moore, James E; Fujioka, Hideki; Gaver, Donald P

    2010-03-01

    In the field of fluid flow within the human body, focus has been placed on the transportation of blood in the systemic circulation since the discovery of that system; but, other fluids and fluid flow phenomena pervade the body. Some of the most fascinating fluid flow phenomena within the human body involve fluids other than blood and a service other than transport--the lymphatic and pulmonary systems are two striking examples. While transport is still involved in both cases, this is not the only service which they provide and blood is not the only fluid involved. In both systems, filtration, extraction, enrichment, and in general some "treatment" of the fluid itself is the primary function. The study of the systemic circulation has also been conventionally limited to treating the system as if it were an open-loop system governed by the laws of fluid mechanics alone, independent of physiological controls and regulations. This implies that system failures can be explained fully in terms of the laws of fluid mechanics, which of course is not the case. In this paper we examine the clinical implications of these issues and of the special biofluid mechanics issues involved in the lymphatic and pulmonary systems.

  1. Diagnosis Of Persistent Infection In Prosthetic Two-Stage Exchange: PCR analysis of Sonication fluid From Bone Cement Spacers.

    PubMed

    Mariaux, Sandrine; Tafin, Ulrika Furustrand; Borens, Olivier

    2017-01-01

    Introduction: When treating periprosthetic joint infections with a two-stage procedure, antibiotic-impregnated spacers are used in the interval between removal of prosthesis and reimplantation. According to our experience, cultures of sonicated spacers are most often negative. The objective of our study was to investigate whether PCR analysis would improve the detection of bacteria in the spacer sonication fluid. Methods: A prospective monocentric study was performed from September 2014 to January 2016. Inclusion criteria were two-stage procedure for prosthetic infection and agreement of the patient to participate in the study. Beside tissues samples and sonication, broad range bacterial PCRs, specific S. aureus PCRs and Unyvero-multiplex PCRs were performed on the sonicated spacer fluid. Results: 30 patients were identified (15 hip, 14 knee and 1 ankle replacements). At reimplantation, cultures of tissue samples and spacer sonication fluid were all negative. Broad range PCRs were all negative. Specific S. aureus PCRs were positive in 5 cases. We had two persistent infections and four cases of infection recurrence were observed, with bacteria different than for the initial infection in three cases. Conclusion: The three different types of PCRs did not detect any bacteria in spacer sonication fluid that was culture-negative. In our study, PCR did not improve the bacterial detection and did not help to predict whether the patient will present a persistent or recurrent infection. Prosthetic 2-stage exchange with short interval and antibiotic-impregnated spacer is an efficient treatment to eradicate infection as both culture- and molecular-based methods were unable to detect bacteria in spacer sonication fluid after reimplantation.

  2. The efficacy of fluid-gas exchange for the treatment of postvitrectomy retinal detachment.

    PubMed

    Jang, Ji Hye; Kim, Yu Cheol; Kim, Kwang Soo

    2009-12-01

    This study was designed to evaluate the efficacy of fluid-gas exchange for the treatment of postvitrectomy retinal detachment. We retrospectively reviewed the records of 33 consecutive patients (35 eyes) who underwent fluid-gas exchange treatment for postvitrectomy retinal detachment using the two-needle pars plana approach technique. The retinal reattachment rate was 80.0% after complete intravitreal gas disappearance following the fluid-gas exchange; the overall success rate was 65.7%. Visual acuity was improved or stable in 80.0% of cases; a two-line or greater vision improvement or a best-corrected visual acuity of 0.4 or better occurred in 62.9% of cases. The success rates for superior retinal detachments and posterior pole retinal detachments were 76.5% and 85.7%, respectively. Fluid-gas exchange represents a simple and cost-effective alternative outpatient procedure for retinal reattachment without reoperation for the treatment of superior and posterior pole retinal detachments.

  3. Preoperative easily misdiagnosed telangiectatic osteosarcoma: clinical-radiologic-pathologic correlations.

    PubMed

    Gao, Zhen-Hua; Yin, Jun-Qiang; Liu, Da-Wei; Meng, Quan-Fei; Li, Jia-Ping

    2013-12-11

    To describe the clinical, imaging, and pathologic characteristics and diagnostic methods of telangiectatic osteosarcoma (TOS) for improving the diagnostic level. The authors retrospectively reviewed patient demographics, serum alkaline phosphatase (AKP) levels, preoperative biopsy pathologic reports, pathologic materials, imaging findings, and treatment outcomes from 26 patients with TOS. Patient images from radiography (26 cases) and magnetic resonance (MR) imaging (22 cases) were evaluated by 3 authors in consensus for intrinsic characteristics. There were 15 male and 11 female patients in the study, with an age of 9-32 years (mean age 15.9 years). Eighteen of 26 patients died of lung metastases within 5 years of follow-up. The distal femur was affected more commonly (14 cases, 53.8%). Regarding serum AKP, normal (8 cases) or mildly elevated (18 cases) levels were found before preoperative chemotherapy. Radiographs showed geographic bone lysis without sclerotic margin (26 cases), cortical destruction (26 cases), periosteal new bone formation (24 cases), soft-tissue mass (23 cases), and matrix mineralization (4 cases). The aggressive radiographic features of TOS simulated the appearance of conventional high-grade intramedullary osteosarcoma, though different from aneurysmal bone cyst. MR images demonstrated multiple big (16 cases) or small (6 cases) cystic spaces, fluid-fluid levels (14 cases), soft-tissue mass (22 cases), and thick peripheral and septal enhancement (22 cases). Nine of 26 cases were misdiagnosed as aneurysmal bone cysts by preoperative core-needle biopsy, owing to the absence of viable high-grade sarcomatous cells in the small tissue samples. The aggressive growth pattern with occasional matrix mineralization, and multiple big or small fluid-filled cavities with thick peripheral, septal, and nodular tissue surrounding the fluid-filled cavities are characteristic imaging features of TOS, and these features are helpful in making the correct preoperative diagnosis of TOS.

  4. Feet swelling in a multistage ultraendurance triathlete: a case study

    PubMed Central

    Knechtle, Beat; Zingg, Matthias Alexander; Knechtle, Patrizia; Rosemann, Thomas; Rüst, Christoph Alexander

    2015-01-01

    Recent studies investigating ultraendurance athletes showed an association between excessive fluid intake and swelling of the lower limbs such as the feet. To date, this association has been investigated in single-stage ultraendurance races, but not in multistage ultraendurance races. In this case study, we investigated a potential association between fluid intake and feet swelling in a multistage ultraendurance race such as a Deca Iron ultratriathlon with ten Ironman triathlons within 10 consecutive days. A 49-year-old well-experienced ultratriathlete competed in autumn 2013 in the Deca Iron ultratriathlon held in Lonata del Garda, Italy, and finished the race as winner within 129:33 hours:minutes. Changes in body mass (including body fat and lean body mass), foot volume, total body water, and laboratory measurements were assessed. Food and fluid intake during rest and competing were recorded, and energy and fluid turnovers were estimated. During the ten stages, the volume of the feet increased, percentage body fat decreased, creatinine and urea levels increased, hematocrit and hemoglobin values decreased, and plasma [Na+] remained unchanged. The increase in foot volume was significantly and positively related to fluid intake during the stages. The poststage volume of the foot was related to poststage total body water, poststage creatinine, and poststage urea. This case report shows that the volume of the foot increased during the ten stages, and the increase in volume was significantly and positively related to fluid intake during the stages. Furthermore, the poststage volume of the foot was related to poststage total body water, poststage creatinine, and poststage urea. The continuous feet swelling during the race was most probably due to a combination of a high fluid intake and a progressive decline in renal function (ie, continuous increase in creatinine and urea), leading to body fluid retention (ie, increase in total body water). PMID:26508884

  5. Aspects of wellbore heat transfer during two-phase flow

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hasan, A.R.; Kabir, C.S.

    1994-08-01

    Wellbore fluid temperature is governed by the rate of heat loss from the wellbore to the surrounding formation, which in turn is a function of depth and production/injection time. The authors present an approach to estimate wellbore fluid temperature during steady-state two-phase flow. The method incorporates a new solution of the thermal diffusivity equation and the effect of both conductive and convective heat transport for the wellbore/formation system. For the multiphase flow in the wellbore, the Hasan-Kabir model has been adapted, although other mechanistic models may be used. A field example is used to illustrate the fluid temperature calculation proceduremore » and shows the importance of accounting for convection in the tubing/casing annulus. A sensitivity study shows that significant differences exist between the predicted wellhead temperature and the formation surface temperature and that the fluid temperature gradient is nonlinear. This study further shows that increased free gas lowers the wellhead temperature as a result of the Joule-Thompson effect. In such cases, the expression for fluid temperature developed earlier for single-phase flow should not be applied when multiphase flow is encountered. An appropriate expression is presented in this work for wellbores producing multiphase fluids.« less

  6. Flow regimes in a T-mixer operating with a binary mixture

    NASA Astrophysics Data System (ADS)

    Camarri, Simone; Siconolfi, Lorenzo; Galletti, Chiara; Salvetti, Maria Vittoria

    2015-11-01

    Efficient mixing in small volumes is a key target in many processes. Among the most common micro-devices, passive T-shaped micro-mixers are widely used. For this reason, T-mixers have been studied in the literature and its working flow regimes have been identified. However, in most of the available theoretical studies it is assumed that only one working fluid is used, i.e. that the same fluid at the same thermodynamic conditions is entering the two inlet conduits of the mixer. Conversely, the practical use of micro-devices often involves the mixing of two different fluids or of the same fluid at different thermodynamic conditions. In this case flow regimes significantly different than those observed for a single working fluid may occur. The present work aims at investigating the flow regimes in a T-mixers when water at two different temperatures, i.e. having different viscosity and density, is entering the mixer. The effect of the temperature difference on the flow regimes in a 3D T-mixer is investigated by DNS and stability analysis and the results are compared to the case in which a single working fluid is employed.

  7. Proposed diagnostic criteria for the case definition of amniotic fluid embolism in research studies

    PubMed Central

    Clark, Steven L.; Romero, Roberto; Dildy, Gary A.; Callaghan, William M.; Smiley, Richard M.; Bracey, Arthur W.; Hankins, Gary D.; D’Alton, Mary E.; Foley, Mike; Pacheco, Luis D.; Vadhera, Rakesh B.; Herlihy, J. Patrick; Berkowitz, Richard L.; Belfort, Michael A.

    2016-01-01

    Amniotic fluid embolism is a leading cause of maternal mortality in developed countries. Our understanding of risk factors, diagnosis, treatment, and prognosis is hampered by a lack of uniform clinical case definition; neither histologic nor laboratory findings have been identified unique to this condition. Amniotic fluid embolism is often overdiagnosed in critically ill peripartum women, particularly when an element of coagulopathy is involved. Previously proposed case definitions for amniotic fluid embolism are nonspecific, and when viewed through the eyes of individuals with experience in critical care obstetrics, would include women with a number of medical conditions much more common than amniotic fluid embolism. We convened a working group under the auspices of a committee of the Society for Maternal-Fetal Medicine and the Amniotic Fluid Embolism Foundation whose task was to develop uniform diagnostic criteria for the research reporting of amniotic fluid embolism. These criteria rely on the presence of the classic triad of hemodynamic and respiratory compromise accompanied by strictly defined disseminated intravascular coagulopathy. It is anticipated that limiting research reports involving amniotic fluid embolism to women who meet these criteria will enhance the validity of published data and assist in the identification of risk factors, effective treatments, and possibly useful biomarkers for this condition. A registry has been established in conjunction with the Perinatal Research Branch of the Eunice Kennedy Shriver National Institute of Child Health and Human Development to collect both clinical information and laboratory specimens of women with suspected amniotic fluid embolism in the hopes of identifying unique biomarkers of this condition. PMID:27372270

  8. Proposed diagnostic criteria for the case definition of amniotic fluid embolism in research studies.

    PubMed

    Clark, Steven L; Romero, Roberto; Dildy, Gary A; Callaghan, William M; Smiley, Richard M; Bracey, Arthur W; Hankins, Gary D; D'Alton, Mary E; Foley, Mike; Pacheco, Luis D; Vadhera, Rakesh B; Herlihy, J Patrick; Berkowitz, Richard L; Belfort, Michael A

    2016-10-01

    Amniotic fluid embolism is a leading cause of maternal mortality in developed countries. Our understanding of risk factors, diagnosis, treatment, and prognosis is hampered by a lack of uniform clinical case definition; neither histologic nor laboratory findings have been identified unique to this condition. Amniotic fluid embolism is often overdiagnosed in critically ill peripartum women, particularly when an element of coagulopathy is involved. Previously proposed case definitions for amniotic fluid embolism are nonspecific, and when viewed through the eyes of individuals with experience in critical care obstetrics, would include women with a number of medical conditions much more common than amniotic fluid embolism. We convened a working group under the auspices of a committee of the Society for Maternal-Fetal Medicine and the Amniotic Fluid Embolism Foundation whose task was to develop uniform diagnostic criteria for the research reporting of amniotic fluid embolism. These criteria rely on the presence of the classic triad of hemodynamic and respiratory compromise accompanied by strictly defined disseminated intravascular coagulopathy. It is anticipated that limiting research reports involving amniotic fluid embolism to women who meet these criteria will enhance the validity of published data and assist in the identification of risk factors, effective treatments, and possibly useful biomarkers for this condition. A registry has been established in conjunction with the Perinatal Research Branch of the Eunice Kennedy Shriver National Institute of Child Health and Human Development to collect both clinical information and laboratory specimens of women with suspected amniotic fluid embolism in the hopes of identifying unique biomarkers of this condition. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. Viral Communities Associated with Human Pericardial Fluids in Idiopathic Pericarditis

    PubMed Central

    Fancello, Laura; Monteil, Sonia; Popgeorgiev, Nikolay; Rivet, Romain; Gouriet, Frédérique; Fournier, Pierre-Edouard; Raoult, Didier; Desnues, Christelle

    2014-01-01

    Pericarditis is a common human disease defined by inflammation of the pericardium. Currently, 40% to 85% of pericarditis cases have no identified etiology. Most of these cases are thought to be caused by an infection of undetected, unsuspected or unknown viruses. In this work, we used a culture- and sequence-independent approach to investigate the viral DNA communities present in human pericardial fluids. Seven viral metagenomes were generated from the pericardial fluid of patients affected by pericarditis of unknown etiology and one metagenome was generated from the pericardial fluid of a sudden infant death case. As a positive control we generated one metagenome from the pericardial fluid of a patient affected by pericarditis caused by herpesvirus type 3. Furthermore, we used as negative controls a total of 6 pericardial fluids from 6 different individuals affected by pericarditis of non-infectious origin: 5 of them were sequenced as a unique pool and the remaining one was sequenced separately. The results showed a significant presence of torque teno viruses especially in one patient, while herpesviruses and papillomaviruses were present in the positive control. Co-infections by different genotypes of the same viral type (torque teno viruses) or different viruses (herpesviruses and papillomaviruses) were observed. Sequences related to bacteriophages infecting Staphylococcus, Enterobacteria, Streptococcus, Burkholderia and Pseudomonas were also detected in three patients. This study detected torque teno viruses and papillomaviruses, for the first time, in human pericardial fluids. PMID:24690743

  10. Reversible grasp reflexes in normal pressure hydrocephalus.

    PubMed

    Thomas, Rhys H; Bennetto, Luke; Silva, Mark T

    2009-05-01

    We present two cases of normal pressure hydrocephalus in combination with grasp reflexes. In both cases the grasp reflexes disappeared following high volume cerebrospinal fluid removal. In one of the cases the grasp reflexes returned over a period of weeks but again resolved following definitive cerebrospinal fluid shunting surgery, and remained absent until final follow up at 9 months. We hypothesise that resolving grasp reflexes following high volume CSF removal has both diagnostic and prognostic value in normal pressure hydrocephalus, encouraging larger studies on the relevance of primitive reflexes in NPH.

  11. Finite element solutions of free convective Casson fluid flow past a vertically inclined plate submitted in magnetic field in presence of heat and mass transfer

    NASA Astrophysics Data System (ADS)

    Raju, R. Srinivasa; Reddy, B. Mahesh; Reddy, G. Jithender

    2017-09-01

    The aim of this research work is to study the influence of thermal radiation on steady magnetohydrodynamic-free convective Casson fluid flow of an optically thick fluid over an inclined vertical plate with heat and mass transfer. Combined phenomenon of heat and mass transfer is considered. Numerical solutions in general form are obtained by using the finite element method. The sum of thermal and mechanical parts is expressed as velocity of fluid. Corresponding limiting solutions are also reduced from the general solutions. It is found that the obtained numerical solutions satisfy all imposed initial and boundary conditions and reduce to some known solutions from the literature as special cases. Numerical results for the controlling flow parameters are drawn graphically and discussed in detail. In some special cases, the obtained numerical results are compared and found to be in good agreement with the previously published results which are available in literature. Applications of this study includes laminar magneto-aerodynamics, materials processing and magnetohydrodynamic propulsion thermo-fluid dynamics, etc.

  12. Numerical simulations of stick-slip in fluid saturated granular fault gouge

    NASA Astrophysics Data System (ADS)

    Dorostkar, O.; Johnson, P. A.; Guyer, R. A.; Marone, C.; Carmeliet, J.

    2016-12-01

    Fluids play a key role in determining the frictional strength and stability of faults. For example, fluid flow and fluid-solid interaction in fault gouge can trigger seismicity, alter earthquake nucleation properties and cause fault zone weakening. We present results of 3D numerical simulations of stick-slip behavior in dry and saturated granular fault gouge. In the saturated case, the gouge is fully saturated and drainage is possible through the boundaries. We model the solid phase (particles) with the discrete element method (DEM) while the fluid is described by the Navier-Stokes equations and solved by computational fluid dynamics (CFD). In our model, granular gouge is sheared between two rough plates under boundary conditions of constant normal stress and constant shearing velocity at the layer boundaries. A phase-space study including shearing velocity and normal stress is taken to identify the conditions for stick-slip regime. We analyzed slip events for dry and saturated cases to determine shear stress drop, released kinetic energy and compaction. The presence of fluid tends to cause larger slip events. We observe a close correlation between the kinetic energy of the particles and of the fluid. In short, during slip, fluid flow induced by the failure and compaction of the granular system, mobilizes the particles, which increases their kinetic energy, leading to greater slip. We further observe that the solid-fluid interaction forces are equal or larger than the solid-solid interaction forces during the slip event, indicating the important influence of the fluid on the granular system. Our simulations can explain the behaviors observed in experimental studies and we are working to apply our results to tectonic faults.

  13. The enhancement of friction ridge detail on brass ammunition casings using cold patination fluid.

    PubMed

    James, Richard Michael; Altamimi, Mohamad Jamal

    2015-12-01

    Brass ammunition is commonly found at firearms related crime scenes. For this reason, many studies have focused on evidence that can be obtained from brass ammunition such as DNA, gunshot residue and fingerprints. Latent fingerprints on ammunition can provide good forensic evidence, however; fingerprint development on ammunition casings has proven to be difficult. A method using cold patination fluid is described as a potential tool to enhance friction ridge detail on brass ammunition casings. Current latent fingerprint development methods for brass ammunition have either failed to provide the necessary quality of friction ridge detail or can be very time consuming and require expensive equipment. In this study, the enhancement of fingerprints on live ammunition has been achieved with a good level of detail whilst the development on spent casings has to an extent also been possible. Development with cold patination fluid has proven to be a quick, simple and cost-effective method for fingerprint development on brass ammunition that can be easily implemented for routine police work. Crown Copyright © 2015. Published by Elsevier Ireland Ltd. All rights reserved.

  14. Incidence and evolution of subretinal precipitates in optic disc pit maculopathy.

    PubMed

    Chatziralli, Irini; Theodossiadis, George; Brouzas, Dimitrios; Theodossiadis, Panagiotis

    2017-06-26

    To study the evolution of subretinal precipitates coexistent with optic disc pit (ODP) maculopathy from their appearance at baseline examination until their absorption after successful treatment. Participants in this retrospective, multicenter study were 42 patients with ODP maculopathy, in whom complete ocular examination was performed, including visual acuity (VA) measurement, slit-lamp examination, color or red-free fundus photography, and optical coherence tomography at baseline after surgical treatment. Out of 42 cases, 17 (40.5%) cases of ODP maculopathy, which were examined between 2002 and 2015, were found to have subretinal precipitates associated with multilayer fluid accumulation at baseline. Precipitates were located at the outer part of the photoreceptor layer and remained for 3-6 months after successful treatment and absorption of subretinal fluid. The mean VA was 0.99 ± 0.21 logMAR at baseline and improved to 0.54 ± 0.25 logMAR at the final examination. Macular precipitates in association with signs of disease chronicity, such as multilayer fluid accumulation, became evident at baseline examination. Precipitates' disappearance in 15 out of 17 cases coincided with the absorption of subretinal fluid. The relative low VA at baseline probably could be attributed to the chronicity of the disease.

  15. Electro-osmotic mobility of non-Newtonian fluids

    PubMed Central

    Zhao, Cunlu; Yang, Chun

    2011-01-01

    Electrokinetically driven microfluidic devices are usually used to analyze and process biofluids which can be classified as non-Newtonian fluids. Conventional electrokinetic theories resulting from Newtonian hydrodynamics then fail to describe the behaviors of these fluids. In this study, a theoretical analysis of electro-osmotic mobility of non-Newtonian fluids is reported. The general Cauchy momentum equation is simplified by incorporation of the Gouy–Chapman solution to the Poisson–Boltzmann equation and the Carreau fluid constitutive model. Then a nonlinear ordinary differential equation governing the electro-osmotic velocity of Carreau fluids is obtained and solved numerically. The effects of the Weissenberg number (Wi), the surface zeta potential (ψ¯s), the power-law exponent(n), and the transitional parameter (β) on electro-osmotic mobility are examined. It is shown that the results presented in this study for the electro-osmotic mobility of Carreau fluids are quite general so that the electro-osmotic mobility for the Newtonian fluids and the power-law fluids can be obtained as two limiting cases. PMID:21503161

  16. Definite (microbiologically confirmed) tuberculous meningitis: predictors and prognostic impact.

    PubMed

    Jha, Sneh Kumar; Garg, Ravindra Kumar; Jain, Amita; Malhotra, Hardeep Singh; Verma, Rajesh; Sharma, Praveen Kumar

    2015-12-01

    Microbiological confirmation cannot be obtained in approximately two-third patients with tuberculous meningitis. In this study, we sought to identify epidemiological, clinical, cerebrospinal fluid, and imaging parameters that could indicate the possibility of microbiological confirmation among patients with suspected tuberculous meningitis. In this prospective observational study, patients with tuberculous meningitis were evaluated for clinical, laboratory (cerebrospinal fluid microscopy, culture, and polymerase chain reaction), and neuroimaging parameters. All patients received anti-tuberculosis drugs and corticosteroids. The patients were followed for a period of 6 months. Among 118 cases of tuberculous meningitis, there were 43 (36 %) definite (microbiologically confirmed) cases, 59 (50 %) probable and 16 (14 %) possible cases. Among 43 definite cases, tuberculosis polymerase chain reaction (PCR) was positive in 42 (35 %) patients, culture was positive in 1 case and microscopy, after Ziehl-Neelsen staining, was positive in 3 cases. Three factors, modified Barthel index score at admission ≤12 (p = 0.008), cerebrospinal fluid total cell count >100/mm(3) (p = 0.016), and basal exudates on imaging (p = 0.015), were significantly associated with definite tuberculous meningitis. Among 20 patients who died within 6 months, 13 belonged to definite tuberculous meningitis group (p < 0.001). Stage III tuberculous meningitis (p = 0.004), baseline-modified Barthel index score ≤12 (p = 0.013), and positive tuberculosis PCR (p = 0.007) were independently associated with poor outcome on multivariate analysis. Severe disability, cerebrospinal fluid cells >100 mm(3), and basal exudates are significantly related to the presence of microbiologically confirmed definite tuberculous meningitis. Microbiologically confirmed tuberculous meningitis is associated with poorer outcome.

  17. Metalworking fluid-associated hypersensitivity pneumonitis: a workshop summary.

    PubMed

    Kreiss, K; Cox-Ganser, J

    1997-10-01

    A workshop discussing eight clusters of hypersensitivity pneumonitis in the automotive industry among metalworking fluid-exposed workers concluded that a risk exists for this granulomatous lung disease where water-based fluids are used and unusual microbial contaminants predominate. Strong candidates for microbial etiology are nontuberculous mycobacteria and fungi. Cases of hypersensitivity pneumonitis occur among cases with other work-related respiratory symptoms and chest diseases. Reversibility of disease has occurred in many cases with exposure cessation, allowing return to work to jobs without metalworking fluid exposures or, in some situations, to jobs without the same metalworking fluid exposures. Cases have been recognized with metalworking fluid exposures generally less than 0.5 mg/m3. The workshop participants identified knowledge gaps regarding risk factors, exposure-response relationships, intervention efficacy, and natural history, as well as surveillance needs to define the extent of the problem in this industry. In the absence of answers to these questions, guidance for prevention is necessarily limited.

  18. Surface effects on friction-induced fluid heating in nanochannel flows.

    PubMed

    Li, Zhigang

    2009-02-01

    We investigate the mechanism of friction-induced fluid heating under the influence of surfaces. The temperature distributions of liquid argon and helium in nanoscale Poiseuille flows are studied through molecular dynamics simulations. It is found that the fluid heating is mainly caused by the viscous friction in the fluid when the external force is small and there is no slip at the fluid-solid interface. When the external force is larger than the fluid-surface binding force, the friction at the fluid-solid interface dominates over the internal friction of the fluid and is the major contribution to fluid heating. An asymmetric temperature gradient in the fluid is developed in the case of nonidentical walls and the general temperature gradient may change sign as the dominant heating factor changes from internal to interfacial friction with increasing external force. The effect of temperature on the fluid heating is also discussed.

  19. Can a Morel-Lavallée lesion be misdiagnosed as a mass like lesion?

    PubMed

    Lee, Yoon Jae; Kim, Jun Hyeok; Kim, Ji Young; Han, Hyun Ho

    2017-12-01

    The Morel-Lavallée lesion (MLL) is a post-traumatic closed soft tissue degloving injury. Common complaints of MLL patients are a haematoma or fluid collection on the trunk or the lower extremity. However, the authors introduce unique cases of MLL that present an atypical appearance. The fluid collection was not apparent, and the capsule formation was not detected on preoperative image study. The main complaint of patients was the uncomfortable mass-like lesion that was regarded as a simple benign lump. The purpose of this case study is to introduce the atypical cases of MLL and to help other physicians make accurate diagnosis based on trial and error of our cases. © 2017 Medicalhelplines.com Inc and John Wiley & Sons Ltd.

  20. Thermal and fluid-dynamics behavior of circulating systems in the case of pressure relief

    NASA Astrophysics Data System (ADS)

    Moeller, L.

    Aspects of safety in the case of large-scale installations with operational high-pressure conditions must be an important consideration already during the design of such installations, taking into account all conceivable disturbances. Within an analysis of such disturbances, studies related to pressure relief processes will have to occupy a central position. For such studies, it is convenient to combine experiments involving small-scale models of the actual installation with suitable computational programs. The experiments can be carried out at lower pressures and temperatures if the actual fluid is replaced by another medium, such as, for instance, a refrigerant. This approach has been used in the present investigation. The obtained experimental data are employed as a basis for a verification of the results provided by the computational model 'Frelap-UK' which has been expressly developed for the analysis of system behavior in the case of pressure relief. It is found that the computer fluid-dynamics characteristics agree with the experimental results.

  1. Investigation of problems of closing of geophysical cracks in thermoelastic media in the case of flow of fluids with impurities

    NASA Astrophysics Data System (ADS)

    Martirosyan, A. N.; Davtyan, A. V.; Dinunts, A. S.; Martirosyan, H. A.

    2018-04-01

    The purpose of this article is to investigate a problem of closing cracks by building up a layer of sediments on surfaces of a crack in an infinite thermoelastic medium in the presence of a flow of fluids with impurities. The statement of the problem of closing geophysical cracks in the presence of a fluid flow is presented with regard to the thermoelastic stress and the influence of the impurity deposition in the liquid on the crack surfaces due to thermal diffusion at the fracture closure. The Wiener–Hopf method yields an analytical solution in the special case without friction. Numerical calculations are performed in this case and the dependence of the crack closure time on the coordinate is plotted. A similar spatial problem is also solved. These results generalize the results of previous studies of geophysical cracks and debris in rocks, where the closure of a crack due to temperature effects is studied without taking the elastic stresses into account.

  2. New strategy for the survey of Toxoplasma gondii in meat for human consumption.

    PubMed

    Villena, Isabelle; Durand, Benoit; Aubert, Dominique; Blaga, Radu; Geers, Régine; Thomas, Myriam; Perret, Catherine; Alliot, Annie; Escotte-Binet, Sandie; Thébault, Anne; Boireau, Pascal; Halos, Lénaïg

    2012-02-10

    Monitoring of Toxoplasma infection in animals destined for human consumption is a great challenge for human toxoplasmosis prevention. This study aimed to compare results obtained from a naturally infected population of sheep using different tests and targeting an original matrix: meat samples and muscle fluids collected at the slaughterhouse. A commercial ELISA test was performed on diaphragm fluids from 419 ovine carcasses collected at the slaughterhouse. A MAT (modified agglutination test) was performed on heart fluids obtained from the same animals. In addition, all hearts were bioassayed in mice. Serological test agreement, the relative sensitivity of ELISA MAT and mouse bioassay as well as a correlation between titres and parasite isolation probability were statistically evaluated. The overall agreement (kappa coefficient=0.64) of ELISA on diaphragm fluids and MAT on heart fluids is substantial and subsequently both tests can be used for epidemiological studies. Relative sensitivity was higher for MAT performed on cardiac fluids (90%) than ELISA on diaphragm fluid (61%). For both serological tests, relative sensitivity is lower in lambs younger than 12 months. Relative sensitivity of mouse inoculation was 42%. A significant correlation was obtained between increasing MAT titres and probability to isolate live parasite from the heart. When the fluid titre was higher than 1:16, parasites were isolated in 65% of cases. When it was lower, isolation failed in 95% of the cases. According to our results, cardiac fluids appear to be a relevant matrix for toxoplasmosis survey in meat. Copyright © 2011 Elsevier B.V. All rights reserved.

  3. Fluid overload and kidney failure in children with severe sepsis and septic shock: A cohort study.

    PubMed

    Naveda Romero, Omar E; Naveda Meléndez, Andrea F

    2017-04-01

    In children with sepsis, fluid overload as a result of an aggressive fluid replacement or excessive fluid administration may result in kidney impairment and increased mortality. Objective. To determine the association between fluid overload and the rate of kidney failure in a group of children with severe sepsis and septic shock. This was a prospective cohort study conducted in the intensive care unit of Hospital Universitario de Pediatría “Dr. Agustín Zubillaga” (Barquisimeto, Lara State, Venezuela), between March 2013 and May 2016, in children with severe sepsis or septic shock. One hundred and forty-nine patients were included in the analysis. Sepsis predominated in 59.7% of cases; patients' average age was 6.4 ± 3.3 years old, their average weight was 17.8 ± 3.6 kg, 30.2% had fluid overload, and overall mortality was 25.5%. Kidney failure occurred in 16.1% of cases. A binary logistic regression model was used to identify fluid overload (odds ratio [OR]: 1.5; 95% confidence interval [CI]: 1.2-4.9, p = 0.028) and shock for more than 2 days (OR: 1.7; 95% CI: 1.3-6.3, p = 0.039) as independent predictors of kidney failure. In addition, a significant increase in the risk of mortality among children with kidney failure and fluid overload was observed as per the Kaplan-Meier method (p= 0.019). Fluid overload and shock for more than 2 days increase the risk for kidney failure in critically ill children with severe sepsis and septic shock.

  4. Dynamic stabilization of Rayleigh-Taylor instability: Experiments with Newtonian fluids as surrogates for ablation fronts

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rodriguez Prieto, G.; Piriz, A. R.; Lopez Cela, J. J.

    2013-01-15

    A previous theory on dynamic stabilization of Rayleigh-Taylor instability at interfaces between Newtonian fluids is reformulated in order to make evident the analogy of this problem with the related one on dynamic stabilization of ablation fronts in the framework of inertial confinement fusion. Explicit analytical expressions are obtained for the boundaries of the dynamically stable region which turns out to be completely analogue to the stability charts obtained for the case of ablation fronts. These results allow proposing experiments with Newtonian fluids as surrogates for studying the case of ablation fronts. Experiments with Newtonian fluids are presented which demonstrate themore » validity of the theoretical approach and encourage to pursue experimental research on ablation fronts to settle the feasibility of dynamic stabilization in the inertial confinement fusion scenario.« less

  5. Fluid-structure coupling for an oscillating hydrofoil

    NASA Astrophysics Data System (ADS)

    Münch, C.; Ausoni, P.; Braun, O.; Farhat, M.; Avellan, F.

    2010-08-01

    Fluid-structure investigations in hydraulic machines using coupled simulations are particularly time-consuming. In this study, an alternative method is presented that linearizes the hydrodynamic load of a rigid, oscillating hydrofoil. The hydrofoil, which is surrounded by incompressible, turbulent flow, is modeled with forced and free pitching motions, where the mean incidence angle is 0° with a maximum angle amplitude of 2°. Unsteady simulations of the flow, performed with ANSYS CFX, are presented and validated with experiments which were carried out in the EPFL High-Speed Cavitation Tunnel. First, forced motion is investigated for reduced frequencies ranging from 0.02 to 100. The hydrodynamic load is modeled as a simple combination of inertia, damping and stiffness effects. As expected, the potential flow analysis showed the added moment of inertia is constant, while the fluid damping and the fluid stiffness coefficients depend on the reduced frequency of the oscillation motion. Behavioral patterns were observed and two cases were identified depending on if vortices did or did not develop in the hydrofoil wake. Using the coefficients identified in the forced motion case, the time history of the profile incidence is then predicted analytically for the free motion case and excellent agreement is found for the results from coupled fluid-structure simulations. The model is validated and may be extended to more complex cases, such as blade grids in hydraulic machinery.

  6. Osmosis-driven viscous fingering of oil-in-water emulsions

    NASA Astrophysics Data System (ADS)

    Liu, Ying; Rallabandi, Bhargav; Baskaran, Mrudhula; Stone, Howard

    2017-11-01

    Viscous fingering occurs when a low viscosity fluid invades a more viscous fluid. Fingering of two miscible fluids is more complicated than that of immiscible fluids in that there is no sharp fluid-fluid interface and diffusion occurs between the phases. We experimentally studied the fingering of two miscible fluids: an oil-in-water emulsion and a sodium chloride solution. When the concentration of sodium chloride in the water phase in the emulsion exceeds that in the sodium chloride solution, the consequent osmotic flow automatically facilitates the occurrence of the fingering. On the contrary, when the sodium chloride solution has higher concentration, the spreading of emulsion is more uniform than the case without the concentration difference. We provide a model to rationalize and quantify these observations.

  7. Fluid Mechanics: The Pamphlet

    NASA Astrophysics Data System (ADS)

    Variano, Evan

    2012-11-01

    One impediment to student learning in introductory fluid mechanics courses is that the fundamental laws of physics can become lost in the ``noise'' of dozens of semi-empirical equations describing special cases. This can be exacerbated by trends in textbooks and other teaching media. This talk will explore a minimalist approach, whereby the entire content of introductory fluids is distilled to a single 1-page pamphlet, designed to emphasize the governing equations and their near-universal applicability. We are particularly interested in hearing feedback from the audience on ways to further distill the content while keeping it accessible and useful. To further emphasize the difference between the fundamental laws and the many specific cases, we have begun assembling a complementary resource: a field guide to fluid phenomena, which mixes the approach of Van Dyke's book with a standard field guide. This is designed to emphasize that there is a ``zoology'' of fluid phenomena, to which the same small set of fundamental laws has been applied repeatedly. These materials may be useful in helping AP Physics teachers cover fluid mechanics, which is an under-utilized opportunity to introduce young scientists to our field of study.

  8. A study examining the effects of water-miscible cutting fluids for end milling process of carbon fiber reinforced plastic

    NASA Astrophysics Data System (ADS)

    Anan, Ruito; Matsuoka, Hironori; Ono, Hajime; Ryu, Takahiro; Nakae, Takashi; Shuto, Schuichi; Watanabe, Suguru; Sato, Yuta

    2017-04-01

    This study examined the improvements to the tool life and finished surface roughness by using water-miscible cutting fluids in carbon fiber reinforced plastics end milling. In cutting tests, it was found that the use of emulsion type, soluble type, and solution type cutting fluids improved tool life compared with the case of dry cutting. Specifically, significant differences in tool life were observed at a high cutting speed of 171 m/min. In addition, the finished surface exhibited a low level of roughness when the solution type cutting fluid was used, regardless of the cutting speed.

  9. New mathematics for old physics: The case of lattice fluids

    NASA Astrophysics Data System (ADS)

    Barberousse, Anouk; Imbert, Cyrille

    2013-08-01

    We analyze the effects of the introduction of new mathematical tools on an old branch of physics by focusing on lattice fluids, which are cellular automata (CA)-based hydrodynamical models. We examine the nature of these discrete models, the type of novelty they bring about within scientific practice and the role they play in the field of fluid dynamics. We critically analyze Rohrlich's, Fox Keller's and Hughes' claims about CA-based models. We distinguish between different senses of the predicates "phenomenological" and "theoretical" for scientific models and argue that it is erroneous to conclude, as they do, that CA-based models are necessarily phenomenological in any sense of the term. We conversely claim that CA-based models of fluids, though at first sight blatantly misrepresenting fluids, are in fact conservative as far as the basic laws of statistical physics are concerned and not less theoretical than more traditional models in the field. Based on our case-study, we propose a general discussion of the prospect of CA for modeling in physics. We finally emphasize that lattice fluids are not just exotic oddities but do bring about new advantages in the investigation of fluids' behavior.

  10. Integral Equation Study of Molecular Fluids and Liquid Crystals in Two Dimensions

    NASA Astrophysics Data System (ADS)

    Ward, David Atlee

    The Ornstein-Zernike (OZ) equation is solved with a Percus-Yevick (PY) closure for the hard ellipse and hard planar dumbell fluids in two dimensions. The correlation functions, including the orientation correlation function, are expanded in a set of orthogonal functions and the coefficients are solved for using an iterative algorithm developed by Lado. The pressure, compressibility, and orientation coefficients are computed for a variety of densities and molecular elongations. The hard planar dumbell fluid shows no orientational ordering. The PY values for the pressure differ from the corresponding Monte Carlo (MC) values by as much as 8% for the cases studied. The hard ellipse fluid exhibits some orientational ordering. Ordering is much more pronounced for ellipses with an axis ratio larger than 2.0. Pressure values computed for the hard ellipse fluid from the PY theory differ from the corresponding MC values by as much as 11% for the cases studied. As the PY solutions do exhibit a nematic character in the hard ellipse fluid, we find it to be a viable reference system for further studies of the nematic liquid crystal phase, though the isotropic-nematic (I-N) phase transition found by Vieillard-Baron was not observed in the PY solutions. The Maier-Saupe theory was reformulated based on the density functional formalism of Sluckin and Shukla. Using PY data of the hard ellipse as input for the direct correlation function in the isotropic phase, the orientational distribution was calculated. The values obtained showed only extremely weak nematic behavior.

  11. A Comprehensive Prediction Model of Hydraulic Extended-Reach Limit Considering the Allowable Range of Drilling Fluid Flow Rate in Horizontal Drilling.

    PubMed

    Li, Xin; Gao, Deli; Chen, Xuyue

    2017-06-08

    Hydraulic extended-reach limit (HERL) model of horizontal extended-reach well (ERW) can predict the maximum measured depth (MMD) of the horizontal ERW. The HERL refers to the well's MMD when drilling fluid cannot be normally circulated by drilling pump. Previous model analyzed the following two constraint conditions, drilling pump rated pressure and rated power. However, effects of the allowable range of drilling fluid flow rate (Q min  ≤ Q ≤ Q max ) were not considered. In this study, three cases of HERL model are proposed according to the relationship between allowable range of drilling fluid flow rate and rated flow rate of drilling pump (Q r ). A horizontal ERW is analyzed to predict its HERL, especially its horizontal-section limit (L h ). Results show that when Q min  ≤ Q r  ≤ Q max (Case I), L h depends both on horizontal-section limit based on rated pump pressure (L h1 ) and horizontal-section limit based on rated pump power (L h2 ); when Q min  < Q max  < Q r (Case II), L h is exclusively controlled by L h1 ; while L h is only determined by L h2 when Q r  < Q min  < Q max (Case III). Furthermore, L h1 first increases and then decreases with the increase in drilling fluid flow rate, while L h2 keeps decreasing as the drilling fluid flow rate increases. The comprehensive model provides a more accurate prediction on HERL.

  12. Relativistic polytropic spheres with electric charge: Compact stars, compactness and mass bounds, and quasiblack hole configurations

    NASA Astrophysics Data System (ADS)

    Arbañil, José D. V.; Zanchin, Vilson T.

    2018-05-01

    We study the static equilibrium configurations of uncharged and charged spheres composed by a relativistic polytropic fluid, and we compare with those of spheres composed by a nonrelativistic polytropic fluid, the later case being already studied in a previous work [J. D. Arbañil, P. S. Lemos, and V. T. Zanchin, Phys. Rev. D 88, 084023 (2013), 10.1103/PhysRevD.88.084023]. An equation of state connecting the pressure p and the energy density ρ is assumed. In the nonrelativistic fluid case, the connection is through a nonrelativistic polytropic equation of state, p =ω ργ , with ω and γ being respectively the polytropic constant and the polytropic exponent. In the relativistic fluid case, the connection is through a relativistic polytropic equation of state, p =ω δγ, with δ =ρ -p /(γ -1 ), and δ being the rest-mass density of the fluid. For the electric charge distribution, we assume that the charge density ρe is proportional to the energy density ρ , ρe=α ρ , with α being a constant such that 0 ≤|α |≤1 . The study is developed by integrating numerically the hydrostatic equilibrium equation. Some properties of the charged spheres such as the gravitational mass, the total electric charge, the radius, the surface redshift, and the speed of sound are analyzed by varying the central rest-mass density, the charge fraction, and the polytropic exponent. In addition, some limits that arise in general relativity, such as the Chandrasekhar limit, the Oppenheimer-Volkoff limit, the Buchdahl bound, and the Buchdahl-Andréasson bound are studied. It is confirmed that charged relativistic polytropic spheres with γ →∞ and α →1 saturate the Buchdahl-Andréasson bound, thus indicating that it reaches the quasiblack hole configuration. We show by means of numerical analysis that, as expected, the major differences between the two cases appear in the high energy density region.

  13. Spherical accretion of matter by charged black holes on f(T) Gravity

    NASA Astrophysics Data System (ADS)

    Rodrigues, M. E.; Junior, E. L. B.

    2018-03-01

    We studied the spherical accretion of matter by charged black holes on f(T) Gravity. Considering the accretion model of a isentropic perfect fluid we obtain the general form of the Hamiltonian and the dynamic system for the fluid. We have analysed the movements of an isothermal fluid model with p=ω e and where p is the pressure and e the total energy density. The analysis of the cases shows the possibility of spherical accretion of fluid by black holes, revealing new phenomena as cyclical movement inside the event horizon.

  14. Preoperative easily misdiagnosed telangiectatic osteosarcoma: clinical–radiologic–pathologic correlations

    PubMed Central

    Gao, Zhen-Hua; Yin, Jun-Qiang; Liu, Da-Wei; Meng, Quan-Fei

    2013-01-01

    Abstract Purpose: To describe the clinical, imaging, and pathologic characteristics and diagnostic methods of telangiectatic osteosarcoma (TOS) for improving the diagnostic level. Materials and methods: The authors retrospectively reviewed patient demographics, serum alkaline phosphatase (AKP) levels, preoperative biopsy pathologic reports, pathologic materials, imaging findings, and treatment outcomes from 26 patients with TOS. Patient images from radiography (26 cases) and magnetic resonance (MR) imaging (22 cases) were evaluated by 3 authors in consensus for intrinsic characteristics. There were 15 male and 11 female patients in the study, with an age of 9–32 years (mean age 15.9 years). Results: Eighteen of 26 patients died of lung metastases within 5 years of follow-up. The distal femur was affected more commonly (14 cases, 53.8%). Regarding serum AKP, normal (8 cases) or mildly elevated (18 cases) levels were found before preoperative chemotherapy. Radiographs showed geographic bone lysis without sclerotic margin (26 cases), cortical destruction (26 cases), periosteal new bone formation (24 cases), soft-tissue mass (23 cases), and matrix mineralization (4 cases). The aggressive radiographic features of TOS simulated the appearance of conventional high-grade intramedullary osteosarcoma, though different from aneurysmal bone cyst. MR images demonstrated multiple big (16 cases) or small (6 cases) cystic spaces, fluid-fluid levels (14 cases), soft-tissue mass (22 cases), and thick peripheral and septal enhancement (22 cases). Nine of 26 cases were misdiagnosed as aneurysmal bone cysts by preoperative core-needle biopsy, owing to the absence of viable high-grade sarcomatous cells in the small tissue samples. Conclusion: The aggressive growth pattern with occasional matrix mineralization, and multiple big or small fluid-filled cavities with thick peripheral, septal, and nodular tissue surrounding the fluid-filled cavities are characteristic imaging features of TOS, and these features are helpful in making the correct preoperative diagnosis of TOS. PMID:24334494

  15. Self-report versus direct measurement for assessment of fluid intake during a 70.3-mile triathlon.

    PubMed

    Wilson, Patrick B; Rhodes, Gregory S; Ingraham, Stacy J

    2015-07-01

    Self-report (SR) has been the primary method used to assess fluid intake during endurance events, but unfortunately, little is known about the validity of SR. The purpose of this study was to compare SR fluid intake with direct measurement (DM) during a 70.3-mile triathlon. Fifty-three (42 men, 11 women) individuals competing in a 70.3-mile triathlon participated in the study. On the 13.1-mile-run section of the triathlon, 11 research stations provided fluid in bottles filled with 163 mL of water or carbohydrate-electrolyte beverage (CEB). Participants submitted bottles 25 m past aid stations to be reweighed postrace. Participants also answered questions regarding fluid intake postrace. Bland-Altman plots and 95% limits of agreement were used to assess precision of the measures, while least-squares regression assessed linear agreement. SR intakes during the run ranged from 0-1793, 0-1837, and 0-2628 mL for water, CEB, and total fluid, with corresponding DM intakes of 0-1599, 0-1642, and 0-2250 mL. DM and SR showed strong linear agreement for water, CEB, and total fluid (R2=.71, .80, and .80). Mean differences between the measures on the Bland-Altman plots were small (13-41 mL), but relatively large differences (±500 mL) between the measures were apparent for some participants. SR is the predominant methodology used in field studies assessing hydration, despite little to no data confirming its validity. The results herein suggest that fluid-intake-assessment methodology should be chosen on a case-by-case basis and that caution should be used when interpreting data based on SR.

  16. [HIV-1 infection after occupational accidents in the State of Amazonas: first reported case].

    PubMed

    Lucena, Noaldo Oliveira de; Pereira, Flávio Ribeiro; Barros, Flávio Silveira de; Silva, Nélson Barbosa da; Alexandre, Márcia Almeida de Araújo; Castilho, Márcia da Costa; Alecrim, Maria das Graças Costa

    2011-10-01

    The medical care of occupational accidents in Tropical Medicine Foundation Dr. Heitor Dourado (FMT-HVD), involving blood and body fluids, started routinely in 1999. The objective of this report is to emphasize the importance of the measures used for the control of accidents with biological material. This study is carried out after a detailed epidemiological investigation confirmed one case of human immunodeficiency virus (HIV) seroconversion after an occupational accident involving bodily fluids and sharp instruments.

  17. Molecular aspect ratio and anchoring strength effects in a confined Gay-Berne liquid crystal

    NASA Astrophysics Data System (ADS)

    Cañeda-Guzmán, E.; Moreno-Razo, J. A.; Díaz-Herrera, E.; Sambriski, E. J.

    2014-04-01

    Phase diagrams for Gay-Berne (GB) fluids were obtained from molecular dynamics simulations for GB(2, 5, 1, 2) (i.e. short mesogens) and GB(3, 5, 1, 2) (i.e. long mesogens), which yield isotropic, nematic, and smectic-B phases. The long-mesogen fluid also yields the smectic-A phase. Ordered phases of the long-mesogen fluid form at higher temperatures and lower densities when compared to those of the short-mesogen fluid. The effect of confinement under weak and strong substrate couplings in slab geometry was investigated. Compared to the bulk, the isotropic-nematic transition does not shift in temprature significantly for the weakly coupled substrate in either mesogen fluid. However, the strongly coupled substrate shifts the transition to lower temperature. Confinement induces marked stratification in the short-mesogen fluid. This effect diminishes with distance from the substrate, yielding bulk-like behaviour in the slab central region. Fluid stratification is very weak for the long-mesogen fluid, but the strongly coupled substrate induces 'smectisation', an ordering effect that decays with distance. Orientation of the fluid on the substrate depends on the mesogen. There is no preferred orientation in a plane parallel to the substrate for the weakly coupled case. In the strongly coupled case, the mesogen orientation mimics that of adjacent fluid layers. Planar anchoring is observed with a broad distribution of orientations in the weakly coupled case. In the strongly coupled case, the distribution leans toward planar orientations for the short-mesogen fluid, while a marginal preference for tilting persists in the long-mesogen fluid.

  18. Endoscopic Management of Pancreatic Fluid Collections in Children.

    PubMed

    Nabi, Zaheer; Talukdar, Rupjyoti; Reddy, D Nageshwar

    2017-07-15

    The incidence of acute pancreatitis in children has increased over the last few decades. The development of pancreatic fluid collection is not uncommon after severe acute pancreatitis, although its natural course in children and adolescents is poorly understood. Asymptomatic fluid collections can be safely observed without any intervention. However, the presence of clinically significant symptoms warrants the drainage of these fluid collections. Endoscopic management of pancreatic fluid collection is safe and effective in adults. The use of endoscopic ultrasound (EUS)-guided procedure has improved the efficacy and safety of drainage of pancreatic fluid collections, which have not been well studied in pediatric populations, barring a scant volume of small case series. Excellent results of EUS-guided drainage in adult patients also need to be verified in children and adolescents. Endoprostheses used to drain pancreatic fluid collections include plastic and metal stents. Metal stents have wider lumens and become clogged less often than plastic stents. Fully covered metal stents specifically designed for pancreatic fluid collection are available, and initial studies have shown encouraging results in adult patients. The future of endoscopic management of pancreatic fluid collection in children appears promising. Prospective studies with larger sample sizes are required to establish their definitive role in the pediatric age group.

  19. Perturbed Newtonian description of the Lemaître model with non-negligible pressure

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yamamoto, Kazuhiro; Marra, Valerio; Mukhanov, Viatcheslav

    2016-03-01

    We study the validity of the Newtonian description of cosmological perturbations using the Lemaître model, an exact spherically symmetric solution of Einstein's equation. This problem has been investigated in the past for the case of a dust fluid. Here, we extend the previous analysis to the more general case of a fluid with non-negligible pressure, and, for the numerical examples, we consider the case of radiation (P=ρ/3). We find that, even when the density contrast has a nonlinear amplitude, the Newtonian description of the cosmological perturbations using the gravitational potential ψ and the curvature potential φ is valid as longmore » as we consider sub-horizon inhomogeneities. However, the relation ψ+φ=O(φ{sup 2})—which holds for the case of a dust fluid—is not valid for a relativistic fluid, and an effective anisotropic stress is generated. This demonstrates the usefulness of the Lemaître model which allows us to study in an exact nonlinear fashion the onset of anisotropic stress in fluids with non-negligible pressure. We show that this happens when the characteristic scale of the inhomogeneity is smaller than the sound horizon and that the deviation is caused by the nonlinear effect of the fluid's fast motion. We also find that ψ+φ= [O(φ{sup 2}),O(c{sub s}{sup 2φ} δ)] for an inhomogeneity with density contrast δ whose characteristic scale is smaller than the sound horizon, unless w is close to −1, where w and c{sub s} are the equation of state parameter and the sound speed of the fluid, respectively. On the other hand, we expect ψ+φ=O(φ{sup 2}) to hold for an inhomogeneity whose characteristic scale is larger than the sound horizon, unless the amplitude of the inhomogeneity is large and w is close to −1.« less

  20. EPA Hydraulic Fracturing Study Technical Workshop #2 March 10-11, 2011: Well Integrity Case Study by Lloyd H. Hetrick

    EPA Pesticide Factsheets

    This case study defines well integrity by the prevention of vertical migration of fluids to protect drinking water resources. A generic shale development well is presented, including design, construction, operational phase, and its plug and abandonment.

  1. CT findings of a unicameral calcaneal bone cyst containing a fluid-fluid level.

    PubMed

    Gallagher, Thomas A; Lim-Dunham, Jennifer E; Vade, Aruna

    2007-03-01

    Calcaneal unicameral bone cysts often contain fluid, but rarely contain fluid-fluid levels. We present a case focusing on the CT findings of a large calcaneal bone cyst with a fluid-fluid level and a review of the literature.

  2. A blended learning approach to teach fluid mechanics in engineering

    NASA Astrophysics Data System (ADS)

    Rahman, Ataur

    2017-05-01

    This paper presents a case study on the teaching and learning of fluid mechanics at the University of Western Sydney (UWS), Australia, by applying a blended learning approach (BLA). In the adopted BLA, various flexible learning materials have been made available to the students such as online recorded lectures, online recorded tutorials, hand written tutorial solutions, discussion board and online practice quizzes. The lecture and tutorial class times have been primarily utilised to discuss confusing topics and engage students with practical issues in applying the theories learnt in fluid mechanics. Based on the data of over 734 students over a 4-year period, it has been shown that a BLA has improved the learning experience of the fluid mechanics students in UWS. The overall percentage of student satisfaction in this subject has increased by 18% in the BLA case compared with the traditional one.

  3. Asthma, hypersensitivity pneumonitis and other respiratory diseases caused by metalworking fluids.

    PubMed

    Rosenman, Kenneth D

    2009-04-01

    To highlight advances in understanding the respiratory disease associated with metal machining, a common work process involving approximately 1.2 million workers in the USA. Recent studies emphasize that work-related asthma and hypersensitivity pneumonitis continue to be caused by exposure to metalworking fluid. Identification of an individual patient indicates the need for follow-up investigations at the work site to prevent additional disease and/or identify additional effected individuals. Identification of the causal agent for hypersensitivity pneumonitis has centered on microbial contamination of metalworking fluids with a number of studies focusing on Mycobacterium immunogenum. Both asthma and hypersensitivity pneumonitis occur among workers exposed to metalworking fluid. The incidence of these diseases among such workers is unknown. Outbreaks of these conditions continue to be identified among metal machinists. Whether these are true outbreaks associated with some breakdown in workplace controls or, rather the recognition of ongoing endemic disease that is typically misdiagnosed as pneumonia or common adult onset asthma, needs further evaluation. Further work to elucidate the specific causal agent(s) is necessary to affect effective workplace controls. Treating an identified individual case as an index case with a follow-up workplace investigation will only be possible if practicing physicians interact with public health authorities to report newly diagnosed cases.

  4. Submersible pumping system with heat transfer mechanism

    DOEpatents

    Hunt, Daniel Francis Alan; Prenger, F. Coyne; Hill, Dallas D; Jankowski, Todd Andrew

    2014-04-15

    A submersible pumping system for downhole use in extracting fluids containing hydrocarbons from a well. In one embodiment, the pumping system comprises a rotary induction motor, a motor casing, one or more pump stages, and a cooling system. The rotary induction motor rotates a shaft about a longitudinal axis of rotation. The motor casing houses the rotary induction motor such that the rotary induction motor is held in fluid isolation from the fluid being extracted. The pump stages are attached to the shaft outside of the motor casing, and are configured to impart fluid being extracted from the well with an increased pressure. The cooling system is disposed at least partially within the motor casing, and transfers heat generated by operation of the rotary induction motor out of the motor casing.

  5. Thomas Midgley, Jr., and the Development of New Substances: A Case Study for Chemical Educators

    ERIC Educational Resources Information Center

    Viana, Hélio Elael Bonini; Porto, Paulo Alves

    2013-01-01

    This paper presents a history of chemistry case study focusing on selected aspects of the work of American engineer Thomas Midgley, Jr. (1889-1944): the development of tetraethyl lead as an antiknock gasoline additive and of chlorofluorocarbons (CFCs) as fluids for refrigeration devices. One general aim of this case study is to display the complex…

  6. Production and delivery of a fluid mixture to an annular volume of a wellbore

    DOEpatents

    Hermes, Robert E [Los Alamos, NM; Bland, Ronald Gene [Houston, TX; Foley, Ron Lee [Magnolia, TX; Bloys, James B [Katy, TX; Gonzalez, Manuel E [Kingwood, NM; Daniel, John M [Germantown, TN; Robinson, Ian M [Guisborough, GB; Carpenter, Robert B [Tomball, TX

    2012-01-24

    The methods described herein generally relate to preparing and delivering a fluid mixture to a confined volume, specifically an annular volume located between two concentrically oriented casing strings within a hydrocarbon fluid producing well. The fluid mixtures disclosed herein are useful in controlling pressure in localized volumes. The fluid mixtures comprise at least one polymerizable monomer and at least one inhibitor. The processes and methods disclosed herein allow the fluid mixture to be stored, shipped and/or injected into localized volumes, for example, an annular volume defined by concentric well casing strings.

  7. Overall heat transfer coefficient and pressure drop in a typical tubular exchanger employing alumina nano-fluid as the tube side hot fluid

    NASA Astrophysics Data System (ADS)

    Kabeel, A. E.; Abdelgaied, Mohamed

    2016-08-01

    Nano-fluids are used to improve the heat transfer rates in heat exchangers, especially; the shell-and-tube heat exchanger that is considered one of the most important types of heat exchangers. In the present study, an experimental loop is constructed to study the thermal characteristics of the shell-and-tube heat exchanger; at different concentrations of Al2O3 nonmetallic particles (0.0, 2, 4, and 6 %). This material concentrations is by volume concentrations in pure water as a base fluid. The effects of nano-fluid concentrations on the performance of shell and tube heat exchanger have been conducted based on the overall heat transfer coefficient, the friction factor, the pressure drop in tube side, and the entropy generation rate. The experimental results show that; the highest heat transfer coefficient is obtained at a nano-fluid concentration of 4 % of the shell side. In shell side the maximum percentage increase in the overall heat transfer coefficient has reached 29.8 % for a nano-fluid concentration of 4 %, relative to the case of the base fluid (water) at the same tube side Reynolds number. However; in the tube side the maximum relative increase in pressure drop has recorded the values of 12, 28 and 48 % for a nano-material concentration of 2, 4 and 6 %, respectively, relative to the case without nano-fluid, at an approximate value of 56,000 for Reynolds number. The entropy generation reduces with increasing the nonmetallic particle volume fraction of the same flow rates. For increase the nonmetallic particle volume fraction from 0.0 to 6 % the rate of entropy generation decrease by 10 %.

  8. Controlled Source Electromagnetic Monitoring of Hydraulic Fracturing: Wellbore and Fluid Effects

    NASA Astrophysics Data System (ADS)

    Couchman, M. J.; Everett, M. E.

    2017-12-01

    As unconventional resources become increasingly important, we must tackle the issue of real-time monitoring of the efficiency of unconventional hydrocarbon extraction. Controlled Source Electromagnetics (CSEM) have been used primarily as a marine-based technique to monitor conventional oil bearing reservoirs with a strong resurgence the new millennium. Many of these studies revolving around detecting a thin resistive layer such as a reservoir at 1m - 3km depth. In these cases, the presence of the resistive layer is characterized by a jump in electric field amplitude recorded at the boundary between the layer and the host sediments. The lessons learned from these studies can be applied to terrestrial unconventional settings with appropriate modifications. The work shown here is a means develop methods which enable more reliable terrestrial CSEM monitoring of the flow of injected fluids associated with hydraulic fracturing of unconventional reservoirs and to detect subsurface fluids based on their CSEM signature and in turn, to infer the subsurface flow of electrically conductive injected fluids. The predictive model validated for various 1-D marine, and terrestrial cases focus on the mapping of fluid flow in from a horizontal wellbore in a uniform halfspace using an in-line Horizontal Electric Dipole (HED) with electric field amplitude recorded by an array of electric field sensors. The effect of the of the vertical and horizontal wellbores are documented taking into account the conductivity, size, and thickness of each wellbore. The fracturing fluids flow and conductivity are also taken into account throughout various stages of the fracturing process. In each case, the sensitivity at a location of the surface in-line electric field to a given resistive or conductive layer, due to a source is calculated.

  9. Unsteady MHD Mixed Convection Slip Flow of Casson Fluid over Nonlinearly Stretching Sheet Embedded in a Porous Medium with Chemical Reaction, Thermal Radiation, Heat Generation/Absorption and Convective Boundary Conditions

    PubMed Central

    Ullah, Imran; Bhattacharyya, Krishnendu; Shafie, Sharidan; Khan, Ilyas

    2016-01-01

    Numerical results are presented for the effect of first order chemical reaction and thermal radiation on mixed convection flow of Casson fluid in the presence of magnetic field. The flow is generated due to unsteady nonlinearly stretching sheet placed inside a porous medium. Convective conditions on wall temperature and wall concentration are also employed in the investigation. The governing partial differential equations are converted to ordinary differential equations using suitable transformations and then solved numerically via Keller-box method. It is noticed that fluid velocity rises with increase in radiation parameter in the case of assisting flow and is opposite in the case of opposing fluid while radiation parameter has no effect on fluid velocity in the forced convection. It is also seen that fluid velocity and concentration enhances in the case of generative chemical reaction whereas both profiles reduces in the case of destructive chemical reaction. Further, increase in local unsteadiness parameter reduces fluid velocity, temperature and concentration. Over all the effects of physical parameters on fluid velocity, temperature and concentration distribution as well as on the wall shear stress, heat and mass transfer rates are discussed in detail. PMID:27776174

  10. Characterisation of dissolved organic compounds in hydrothermal fluids by stir bar sorptive extraction - gas chomatography - mass spectrometry. Case study: the Rainbow field (36°N, Mid-Atlantic Ridge)

    PubMed Central

    2012-01-01

    The analysis of the dissolved organic fraction of hydrothermal fluids has been considered a real challenge due to sampling difficulties, complexity of the matrix, numerous interferences and the assumed ppb concentration levels. The present study shows, in a qualitative approach, that Stir Bar Sorptive Extraction (SBSE) followed by Thermal Desorption – Gas Chromatography – Mass Spectrometry (TD-GC-MS) is suitable for extraction of small sample volumes and detection of a wide range of volatile and semivolatile organic compounds dissolved in hydrothermal fluids. In a case study, the technique was successfully applied to fluids from the Rainbow ultramafic-hosted hydrothermal field located at 36°14’N on the Mid-Atlantic Ridge (MAR). We show that n-alkanes, mono- and poly- aromatic hydrocarbons as well as fatty acids can be easily identified and their retention times determined. Our results demonstrate the excellent repeatability of the method as well as the possibility of storing stir bars for at least three years without significant changes in the composition of the recovered organic matter. A preliminary comparative investigation of the organic composition of the Rainbow fluids showed the great potential of the method to be used for assessing intrafield variations and carrying out time series studies. All together our results demonstrate that SBSE-TD-GC-MS analyses of hydrothermal fluids will make important contributions to the understanding of geochemical processes, geomicrobiological interactions and formation of mineral deposits. PMID:23134621

  11. Evaluation of different fluids for detection of Clostridium perfringens type D epsilon toxin in sheep with experimental enterotoxemia.

    PubMed

    Layana, Jorge E; Fernandez Miyakawa, Mariano E; Uzal, Francisco A

    2006-08-01

    Enterotoxemia caused by Clostridium perfringens type D is a highly lethal disease of sheep, goats and other ruminants. The diagnosis of this condition is usually confirmed by detection of epsilon toxin, a major exotoxin produced by C. perfringens types B and D, in the intestinal content of affected animals. It has been suggested that other body fluids can also be used for detection of epsilon toxin. This study was performed to evaluate the usefulness of intestinal content versus other body fluids in detecting epsilon toxin in cases of sheep enterotoxemia. Samples of duodenal, ileal and colon contents, pericardial and abdominal fluids, aqueous humor and urine from 15 sheep with experimentally induced enterotoxemia, were analysed for epsilon toxin using a capture ELISA. Epsilon toxin was detected in 92% of the samples of ileal content, 64% of the samples of duodenal content, 57% of the samples of colon content and in 7% of the samples of pericardial fluid and aqueous humor. No epsilon toxin was found in samples of abdominal fluid or urine from the animals with enterotoxemia or in any samples from six clinically healthy sheep used as negative controls. The results of this study indicate that with the diagnostic capture ELISA used, intestinal content (preferably ileum) should be used for C. perfringens type D epsilon toxin detection in suspected cases of sheep enterotoxemia.

  12. COMPARING PERIPHERAL VITRECTOMY UNDER AIR AND FLUID INFUSION FOR PRIMARY RHEGMATOGENOUS RETINAL DETACHMENT.

    PubMed

    Erdogan, Gurkan; Unlu, Cihan; Karasu, Bugra; Kardes, Esra; Ergin, Ahmet

    2016-07-01

    To evaluate the efficacy and safety of peripheral vitrectomy under air infusion in comparison with fluid infusion in patients undergoing 23-gauge pars plana vitrectomy for primary rhegmatogenous retinal detachment. A total of 80 eyes of 80 patients with primary rhegmatogenous retinal detachment were enrolled into the study. Forty cases underwent peripheral vitrectomy under air infusion (air group), and a control group of equal number underwent peripheral vitrectomy under fluid infusion (fluid group). Peripheral iatrogenic retinal breaks during peripheral vitrectomy, postoperative visual acuities, and retinal redetachment rates were compared. The number of eyes with peripheral iatrogenic retinal breaks in air group during peripheral vitrectomy was statistically comparable with that in fluid group (1/40 and 4/40, 2.5% and 10%, respectively; P = 0.16). Scleral depression was necessitated in 7 of 40 cases (17.5%) during the operation in the air group. There were no statistically significant differences between the groups in means of postoperative visual acuity and retinal redetachment (P = 0.18 and P = 1.0, respectively). Peripheral vitrectomy under air infusion for primary rhegmatogenous retinal detachment revealed comparable results with fluid infusion in terms of intraoperative and postoperative complications and surgical outcomes.

  13. A Blended Learning Approach to Teach Fluid Mechanics in Engineering

    ERIC Educational Resources Information Center

    Rahman, Ataur

    2017-01-01

    This paper presents a case study on the teaching and learning of fluid mechanics at the University of Western Sydney (UWS), Australia, by applying a blended learning approach (BLA). In the adopted BLA, various flexible learning materials have been made available to the students such as online recorded lectures, online recorded tutorials, hand…

  14. Fluid dynamic and thermodynamic analysis of a model pertaining to cryogenic fluid management in low gravity environments for a system with dynamically induced settling

    NASA Technical Reports Server (NTRS)

    Rios, J.

    1982-01-01

    The settling behavior of the liquid and gaseous phases of a fluid in a propellant and in a zero-g environment, when such settling is induced through the use of a dynamic device, in this particular case, a helical screw was studied. Particular emphasis was given to: (1) the description of a fluid mechanics model which seems applicable to the system under consideration, (2) a First Law of Thermodynamics analysis of the system, and (3) a discussion of applicable scaling rules.

  15. A new 3D immersed boundary method for non-Newtonian fluid-structure-interaction with application

    NASA Astrophysics Data System (ADS)

    Zhu, Luoding

    2017-11-01

    Motivated by fluid-structure-interaction (FSI) phenomena in life sciences (e.g., motions of sperm and cytoskeleton in complex fluids), we introduce a new immersed boundary method for FSI problems involving non-Newtonian fluids in three dimensions. The non-Newtonian fluids are modelled by the FENE-P model (including the Oldroyd-B model as an especial case) and numerically solved by a lattice Boltzmann scheme (the D3Q7 model). The fluid flow is modelled by the lattice Boltzmann equations and numerically solved by the D3Q19 model. The deformable structure and the fluid-structure-interaction are handled by the immersed boundary method. As an application, we study a FSI toy problem - interaction of an elastic plate (flapped at its leading edge and restricted nowhere else) with a non-Newtonian fluid in a 3D flow. Thanks to the support of NSF-DMS support under research Grant 1522554.

  16. Instability of multi-layer fluid configurations in the presence of time-dependent accelerations in a microgravity environment

    NASA Technical Reports Server (NTRS)

    Lyell, M. J.; Roh, Michael

    1991-01-01

    The increasing number of research opportunities in a microgravity environment will benefit not only fundamental studies in fluid dynamics, but also technological applications such as those involving materials processing. In particular, fluid configurations which involve fluid-fluid interfaces would occur in a variety of experimental investigations. This work investigates the stability of a configuration involving fluid-fluid interfaces in the presence of a time-dependent forcing. Both periodic (g-jitter) and nonperiodic accelerations are considered. The fluid configuration is multilayered, and infinite in extent. The analysis is linear and inviscid, and the acceleration vector is oriented perpendicular to each interface. A Floquet analysis is employed in the case of the periodic forcing. In the problem of nonperiodic forcing, the resulting system of equations are integrated in time. Specific nondimensional parameters appear in each problem. The configuration behavior is investigated for a range of parameter values.

  17. A pilot study: The effects of repeat washing and fabric type on the detection of seminal fluid and spermatozoa.

    PubMed

    Nolan, A; Speers, Samuel J; Murakami, Julie; Chapman, Brendan

    2018-05-19

    In sexual assault cases and more specifically those involving childhood sexual abuse (CSA), victims may have had their potentially semen-stained clothing washed multiple times before a criminal investigation commences. Although it has been previously demonstrated that spermatozoa persist on cotton clothing following a single wash cycle, items of clothing washed multiple times are not routinely examined in these cases because of the assumption that the laundering process would have removed all seminal fluid and spermatozoa. The aim of this study was to examine the persistence of seminal fluid and spermatozoa on a range of fabric types including cotton, nylon, terry towel (100% cotton), polyester fleece, satin and lace which were laundered up to six times. Three techniques were used for the detection of seminal fluid and spermatozoa: an alternative light source, acid phosphatase test and microscopy. The study demonstrated that spermatozoa persisted on cotton and terry towel following six wash cycles. This data emphasises the need to recover and examine items of clothing and bedding of victims for semen, even if the item has been washed multiple times. Copyright © 2018 Elsevier B.V. All rights reserved.

  18. Endoscopic transpterygoidal repair of a large cranial defect with cerebrospinal fluid leak in a patient with extensive osteoradionecrosis of the skull base: case report and technical note.

    PubMed

    Brand, Y; Lim, E; Waran, V; Prepageran, N

    2015-12-01

    Endoscopic endonasal techniques have recently become the method of choice in dealing with cerebrospinal fluid leak involving the anterior cranial fossa. However, most surgeons prefer an intracranial approach when leaks involve the middle cranial fossa. This case report illustrates the possibilities of using endoscopic techniques for cerebrospinal fluid leaks involving the middle fossa. A 37-year-old male patient presented with multiple areas of cranial defect with cerebrospinal fluid leak due to osteoradionecrosis following radiation for nasopharyngeal carcinoma 4 years earlier. Clinical examination showed involvement of all cranial nerves except the IInd and XIth nerves on the left side. A prior attempt to repair the cerebrospinal fluid leak with craniotomy was not successful. This case demonstrates the successful endoscopic repair of a large cranial defect with cerebrospinal fluid leak.

  19. A Simulation for Teaching the Basic and Clinical Science of Fluid Therapy

    ERIC Educational Resources Information Center

    Rawson, Richard E.; Dispensa, Marilyn E.; Goldstein, Richard E.; Nicholson, Kimberley W.; Vidal, Noni Korf

    2009-01-01

    The course "Management of Fluid and Electrolyte Disorders" is an applied physiology course taught using lectures and paper-based cases. The course approaches fluid therapy from both basic science and clinical perspectives. While paper cases provide a basis for application of basic science concepts, they lack key components of genuine clinical…

  20. Seroprevalence of toxoplasmosis in Korean pregnant women.

    PubMed

    Song, Kyoung-Ju; Shin, Jong-Chul; Shin, Ho-Joon; Nam, Ho-Woo

    2005-06-01

    This study was performed in order to evaluate the sero-epidemiological status of toxoplasmosis in pregnant Korean women. Among 5,175 sera and 750 amniotic fluid samples obtained from pregnant women, 41 serum samples (0.79%) and 10 (1.33%) amniotic fluid samples tested positive for IgG antibodies by ELISA. Fifty one cases showing a score more than 0.25 on ELISA were tested for PCR reaction against the SAG1 gene. Only one case of the 51 ELISA positive cases exhibited a positive reaction on all tests. This case had a history of acute nephropyelitis during early pregnancy, but fortunately, had delivered a phenotypically healthy baby. In this study, the seroprevalence of toxoplasmosis in pregnant women was found to be comparatively low, consistent with previous reports from Korea. However our trials, performed with a variety of diagnostic tools, were considered to be useful for the precise diagnosis of congenital toxoplasmosis.

  1. Cylindrically symmetric cosmological model of the universe in modified gravity

    NASA Astrophysics Data System (ADS)

    Mishra, B.; Vadrevu, Samhita

    2017-02-01

    In this paper, we have constructed the cosmological models of the universe in a cylindrically symmetric space time in two classes of f(R,T) gravity (Harko et al. in Phys. Rev. D 84:024020, 2011). We have discussed two cases: one in the linear form and the other in the quadratic form of R. The matter is considered to be in the form of perfect fluid. It is observed that in the first case, the pressure and energy density remain the same, which reduces to a Zeldovich fluid. In the second case we have studied the quadratic function of f(R,T) gravity in the form f(R)=λ(R+R2) and f(T)=λ T. In the second case the pressure is in the negative domain and the energy density is in the positive domain, which confirms that the equation of state parameter is negative. The physical properties of the constructed models are studied.

  2. A case of perforated sigmoid diverticulitis in which gram staining of ascitic fluid was useful for diagnosis.

    PubMed

    Tsuchida, Junko; Fujita, Shouhei; Kawano, Fumihiro; Tsukamoto, Ryoichi; Honjo, Kunpei; Naito, Shigetoshi; Ishiyama, Shun; Miyano, Shozo; Machida, Michio; Kitabatake, Toshiaki; Fujisawa, Minoru; Kojima, Kuniaki; Ogura, Kanako; Matsumoto, Toshiharu

    2014-01-01

    An 85-year-old woman was admitted to our hospital for steroid therapy for relapsing nephrotic syndrome. During hospitalization, she complained of sudden epigastric pain at night. Although there were signs of peritoneal irritation, CT showed a large amount of ascitic fluid, but no free intraperitoneal gas. Gram staining of ascitic fluid obtained by abdominal paracentesis showed Gram-negative rods, which raised a strong suspicion of gastrointestinal perforation and peritonitis. Therefore, emergency surgery was performed. Exploration of the colon showed multiple sigmoid diverticula, one of which was perforated. The patient underwent an emergency Hartmann's procedure. Imaging studies failed to reveal any evidence of gastrointestinal perforation, presenting a diagnostic challenge. However, a physician performed rapid Gram staining of ascitic fluid at night when laboratory technicians were absent, had a strong suspicion of gastrointestinal perforation, and performed emergency surgery. Gram staining is superior in rapidity, and ascitic fluid Gram staining can aid in diagnosis, suggesting that it should be actively performed. We report this case, with a review of the literature on the significance of rapid diagnosis by Gram staining.

  3. A numerical model of two-phase flow at the micro-scale using the volume-of-fluid method

    NASA Astrophysics Data System (ADS)

    Shams, Mosayeb; Raeini, Ali Q.; Blunt, Martin J.; Bijeljic, Branko

    2018-03-01

    This study presents a simple and robust numerical scheme to model two-phase flow in porous media where capillary forces dominate over viscous effects. The volume-of-fluid method is employed to capture the fluid-fluid interface whose dynamics is explicitly described based on a finite volume discretization of the Navier-Stokes equations. Interfacial forces are calculated directly on reconstructed interface elements such that the total curvature is preserved. The computed interfacial forces are explicitly added to the Navier-Stokes equations using a sharp formulation which effectively eliminates spurious currents. The stability and accuracy of the implemented scheme is validated on several two- and three-dimensional test cases, which indicate the capability of the method to model two-phase flow processes at the micro-scale. In particular we show how the co-current flow of two viscous fluids leads to greatly enhanced flow conductance for the wetting phase in corners of the pore space, compared to a case where the non-wetting phase is an inviscid gas.

  4. Pathways of fluid transport and reabsorption across the peritoneal membrane.

    PubMed

    Asghar, R B; Davies, S J

    2008-05-01

    The three-pore model of peritoneal fluid transport predicts that once the osmotic gradient has dissipated, fluid reabsorption will be due to a combination of small-pore reabsorption driven by the intravascular oncotic pressure, and an underlying disappearance of fluid from the cavity by lymphatic drainage. Our study measured fluid transport by these pathways in the presence and absence of an osmotic gradient. Paired hypertonic and standard glucose-dwell studies were performed using radio-iodinated serum albumin as an intraperitoneal volume marker and changes in intraperitoneal sodium mass to determine small-pore versus transcellular fluid transport. Disappearance of iodinated albumin was considered to indicate lymphatic drainage. Variability in transcellular ultrafiltration was largely explained by the rate of small-solute transport across the membrane. In the absence of an osmotic gradient, fluid reabsorption occurred via the small-pore pathway, the rate being proportional to the small-solute transport characteristics of the membrane. In most cases, fluid removal from the peritoneal cavity by this pathway was faster than by lymphatic drainage. Our study shows that the three-pore model describes the pathways of peritoneal fluid transport well. In the presence of high solute transport, poor transcellular ultrafiltration was due to loss of the osmotic gradient and an enhanced small-pore reabsorption rate after this gradient dissipated.

  5. Subdural fluid collection and hydrocephalus following cervical schwannoma resection: hydrocephalus resolution after spinal pseudomeningocele repair: case report.

    PubMed

    Benedetto, Nicola; Cagnazzo, Federico; Gambacciani, Carlo; Perrini, Paolo

    2016-12-01

    The authors report the case of a 31-year-old man who developed neck pain and headache 2 months after the uncomplicated resection of a cervical schwannoma. MR imaging revealed infratentorial subdural fluid collections and obstructive hydrocephalus associated with cervical pseudomeningocele. The clinical symptoms, subdural fluid collections, and ventricular dilation resolved after surgical correction of the pseudomeningocele. This report emphasizes that hydrocephalus may be related to disorders of cerebrospinal fluid flow dynamics induced by cervical pseudomeningocele. In these rare cases, both the hydrocephalus and the symptoms are resolved by the simple correction of the pseudomeningocele.

  6. First sternocostal degenerative arthritis with intrarticular fluid collection. A case report.

    PubMed

    Chalazonitis, Athanasios N; Condilis, Nicolas; Tilentzoglou, Anastasia C; Pontikis, John; Tzovara, Joannie

    2006-01-01

    A rare case with clinical condition of first sternocostal degenerative arthritis with intra-articular fluid collection that developed after long-lasting intense exercise (weight-lifting) for twenty years is reported. Imaging findings and differential diagnoses of the case are presented.

  7. [Intrapartum amnioinfusion in patients with meconium-stained amniotic fluid].

    PubMed

    Engel, Karina; Samborska, Monika; Bilar, Marek; Sipak-Szmigiel, Olimpia; Ronin-Walknowska, Elzbieta

    2008-09-01

    The aim of the study was to evaluate the effect of intrapartum amnioinfusion in the presence of meconium stained amniotic fluid. 93 women with meconium-stained amniotic fluid were assigned to receive amnioinfusion or no amnioinfusion (128 women). The trials were evaluated for fetal distress syndrome, route of delivery, fetal acidemia, Apgar score at 1 and 5 min., meconium aspiration syndrome, postpartum endometritis and maternal hospital stays. Amnioinfusion in cases of meconium-stained fluid did not improve the number of fetal distress symptoms during fetal heart rate monitoring. Amnioinfusion was associated with a significant decrease of neonatal acidemia although it did not improve Apgar score. In our study amnioinfusion was not associated with reduction in the incidence of neonatal outcome and puerperial complications.

  8. Free Oscillations of a Fluid-filled Cavity in an Infinite Elastic Medium

    NASA Astrophysics Data System (ADS)

    Sakuraba, A.

    2016-12-01

    Volcanic low-frequency earthquakes and tremor have been widely recognized as a good indicator of hidden activities of volcanoes. It is likely that existence or movement of underground magma and geothermal fluids play a crucial role in their generation mechanisms, but there are still many unknowns. This presentation aims to give a fundamental contribution to understanding and interpreting volcanic low-frequency seismic events. The problem we consider is to compute eigen modes of free oscillations of a fluid-filled cavity surrounded by an infinite linearly elastic medium. A standard boundary element method is used to solve fluid and elastic motion around a cavity of arbitrary shape. Nonlinear advection term is neglected, but viscosity is generally considered in a fluid medium. Of a great importance is to find not only characteristic frequencies but attenuation properties of the oscillations, the latter being determined by both viscous dissipation in the fluid cavity and elastic wave radiation to infinity. One of the simplest cases may be resonance of a fluid-filled crack, which has been studied numerically (Chouet, JGR 1986; Yamamoto and Kawakatsu, GJI 2008) and analytically (Maeda and Kumagai, GRL 2013). In the present study, we generally consider a three-dimensional cavity with emphasis on treating the crack model and other simplest models such as spherical and cylindrical resonators as the extreme cases. In order to reduce computational costs, we assume symmetries about three orthogonal planes and calculate the eigen modes separately for each symmetry. The current status of this project is that the computational code has been checked through comparison to eigen modes of a spherical inviscid cavity (Sakuraba et al., EPS 2002), and another comparison to resonance of a fluid-filled crack is undertook.

  9. Estimation of the probability of exposure to metalworking fluids in a population-based case-control study

    PubMed Central

    Park, Dong-Uk; Colt, Joanne S.; Baris, Dalsu; Schwenn, Molly; Karagas, Margaret R.; Armenti, Karla R.; Johnson, Alison; Silverman, Debra T; Stewart, Patricia A

    2014-01-01

    We describe here an approach for estimating the probability that study subjects were exposed to metalworking fluids (MWFs) in a population-based case-control study of bladder cancer. Study subject reports on the frequency of machining and use of specific MWFs (straight, soluble, and synthetic/semi-synthetic) were used to estimate exposure probability when available. Those reports also were used to develop estimates for job groups, which were then applied to jobs without MWF reports. Estimates using both cases and controls and controls only were developed. The prevalence of machining varied substantially across job groups (10-90%), with the greatest percentage of jobs that machined being reported by machinists and tool and die workers. Reports of straight and soluble MWF use were fairly consistent across job groups (generally, 50-70%). Synthetic MWF use was lower (13-45%). There was little difference in reports by cases and controls vs. controls only. Approximately, 1% of the entire study population was assessed as definitely exposed to straight or soluble fluids in contrast to 0.2% definitely exposed to synthetic/semi-synthetics. A comparison between the reported use of the MWFs and the US production levels by decade found high correlations (r generally >0.7). Overall, the method described here is likely to have provided a systematic and reliable ranking that better reflects the variability of exposure to three types of MWFs than approaches applied in the past. PMID:25256317

  10. The limitations of Gram-stain microscopy of synovial fluid in concomitant septic and crystal arthritis.

    PubMed

    Stirling, Paul; Tahir, Mohammed; Atkinson, Henry Dushan

    2017-03-29

    Rapid diagnosis of septic arthritis from Gram-stain microscopy is limited by an inherent false-negative rate of 25-78%. The presence of concomitant crystal arthritis in 5% of cases represents a particular diagnostic challenge. This study aims to investigate the effects that a concomitant crystal arthropathy have on the ability of Gram-stain microscopy of synovial fluid to diagnose a septic arthritis. This is a 12-year retrospective cohort study. Inclusion criteria were a positive synovial fluid culture result with a positive clinical diagnosis of septic arthritis. Results were correlated with presence or absence of urate and calcium pyrophosphate crystals, and Gram-stain result. During this time our collection and analysis methods remained unchanged. All samples were collected in Lithium Heparin containers. Chi-squared test with a p value < 0.05 was considered significant. 602 synovial fluid samples were included. 162 cases of concomitant crystal arthritis were identified (27%). Of these, 16 (10%) had an initial negative Gram-stain. Of the 440 samples with no crystals detected, 18 (4%) had an initial negative Gram-stain microscopy result (p < 0.05). The incidence of concurrent septic and crystal arthritis may be higher than previously thought. Synovial fluid samples in concomitant septic and crystal arthritis are significantly less likely to have a positive Gram-stain at microscopy than in cases of an isolated septic arthritis. We would advise the clinician to maintain a high index of suspicion for septic arthritis in these patients. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  11. Experimental study of the heated contact line region for a pure fluid and binary fluid mixture in microgravity.

    PubMed

    Nguyen, Thao T T; Kundan, Akshay; Wayner, Peter C; Plawsky, Joel L; Chao, David F; Sicker, Ronald J

    2017-02-15

    Understanding the dynamics of phase change heat and mass transfer in the three-phase contact line region is a critical step toward improving the efficiency of phase change processes. Phase change becomes especially complicated when a fluid mixture is used. In this paper, a wickless heat pipe was operated on the International Space Station (ISS) to study the contact line dynamics of a pentane/isohexane mixture. Different interfacial regions were identified, compared, and studied. Using high resolution (50×), interference images, we calculated the curvature gradient of the liquid-vapor interface at the contact line region along the edges of the heat pipe. We found that the curvature gradient in the evaporation region increases with increasing heat flux magnitude and decreasing pentane concentration. The curvature gradient for the mixture case is larger than for the pure pentane case. The difference between the two cases increases as pentane concentration decreases. Our data showed that the curvature gradient profile within the evaporation section is separated into two regions with the boundary between the two corresponding to the location of a thick, liquid, "central drop" region at the point of maximum internal local heat flux. We found that the curvature gradients at the central drop and on the flat surfaces where condensation begins are one order of magnitude smaller than the gradients in the corner meniscus indicating the driving forces for fluid flow are much larger in the corners. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. Identification of Pulmonary Edema in Forensic Autopsy Cases of Sudden Cardiac Death Using Fourier Transform Infrared Microspectroscopy: A Pilot Study.

    PubMed

    Lin, Hancheng; Luo, Yiwen; Sun, Qiran; Zhang, Ji; Tuo, Ya; Zhang, Zhong; Wang, Lei; Deng, Kaifei; Chen, Yijiu; Huang, Ping; Wang, Zhenyuan

    2018-02-20

    Many studies have proven the usefulness of biofluid-based infrared spectroscopy in the clinical domain for diagnosis and monitoring the progression of diseases. Here we present a state-of-the-art study in the forensic field that employed Fourier transform infrared microspectroscopy for postmortem diagnosis of sudden cardiac death (SCD) by in situ biochemical investigation of alveolar edema fluid in lung tissue sections. The results of amide-related spectral absorbance analysis demonstrated that the pulmonary edema fluid of the SCD group was richer in protein components than that of the neurologic catastrophe (NC) and lethal multiple injuries (LMI) groups. The complementary results of unsupervised principle component analysis (PCA) and genetic algorithm-guided partial least-squares discriminant analysis (GA-PLS-DA) further indicated different global spectral band patterns of pulmonary edema fluids between these three groups. Ultimately, a random forest (RF) classification model for postmortem diagnosis of SCD was built and achieved good sensitivity and specificity scores of 97.3% and 95.5%, respectively. Classification predictions of unknown pulmonary edema fluid collected from 16 cases were also performed by the model, resulting in 100% correct discrimination. This pilot study demonstrates that FTIR microspectroscopy in combination with chemometrics has the potential to be an effective aid for postmortem diagnosis of SCD.

  13. Formation of curvature singularities on the interface between dielectric liquids in a strong vertical electric field.

    PubMed

    Kochurin, Evgeny A; Zubarev, Nikolay M; Zubareva, Olga V

    2013-08-01

    The nonlinear dynamics of the interface between two deep dielectric fluids in the presence of a vertical electric field is studied. We consider the limit of a strong external electric field where electrostatic forces dominate over gravitational and capillary forces. The nonlinear integrodifferential equations for the interface motion are derived under the assumption of small interfacial slopes. It is shown in the framework of these equations that, in the generic case, the instability development leads to the formation of root singularities at the interface in a finite time. The interfacial curvature becomes infinite at singular points, while the slope angles remain relatively small. The curvature is negative in the vicinity of singularities if the ratio of the permittivities of the fluids exceeds the inverse ratio of their densities, and it is positive in the opposite case (we consider that the lower fluid is heavier than the upper one). In the intermediate case, the interface evolution equations describe the formation and sharpening of dimples at the interface. The results obtained are applicable for the description of the instability of the interface between two magnetic fluids in a vertical magnetic field.

  14. TRADITIONAL CANISTER-BASED OPEN WASTE MANAGEMENT SYSTEM VERSUS CLOSED SYSTEM: HAZARDOUS EXPOSURE PREVENTION AND OPERATING THEATRE STAFF SATISFACTION.

    PubMed

    Horn, M; Patel, N; MacLellan, D M; Millard, N

    2016-06-01

    Exposure to blood and body fluids is a major concern to health care professionals working in operating rooms (ORs). Thus, it is essential that hospitals use fluid waste management systems that minimise risk to staff, while maximising efficiency. The current study compared the utility of a 'closed' system with a traditional canister-based 'open' system in the OR in a private hospital setting. A total of 30 arthroscopy, urology, and orthopaedic cases were observed. The closed system was used in five, four, and six cases, respectively and the open system was used in nine, two, and four cases, respectively. The average number of opportunities for staff to be exposed to hazardous fluids were fewer for the closed system when compared to the open during arthroscopy and urology procedures. The open system required nearly 3.5 times as much staff time for set-up, maintenance during procedures, and post-procedure disposal of waste. Theatre staff expressed greater satisfaction with the closed system than with the open. In conclusion, compared with the open system, the closed system offers a less hazardous and more efficient method of disposing of fluid waste generated in the OR.

  15. Measuring resistivity changes from within a first cased well to monitor fluids injected into oil bearing geological formations from a second cased well while passing electrical current between the two cased wells

    DOEpatents

    Vail, III, William B.

    1993-01-01

    A.C. current is conducted through geological formations separating two cased wells in an oil field undergoing enhanced oil recovery operations such as water flooding operations. Methods and apparatus are disclosed to measure the current leakage conducted into a geological formation from within a first cased well that is responsive to fluids injected into formation from a second cased well during the enhanced oil production activities. The current leakage and apparent resistivity measured within the first cased well are responsive to fluids injected into formation from the second cased well provided the distance of separation between the two cased wells is less than, or on the order of, a Characteristic Length appropriate for the problem.

  16. Measuring resistivity changes from within a first cased well to monitor fluids injected into oil bearing geological formations from a second cased well while passing electrical current between the two cased wells

    DOEpatents

    Vail, W.B. III.

    1993-02-16

    A.C. current is conducted through geological formations separating two cased wells in an oil field undergoing enhanced oil recovery operations such as water flooding operations. Methods and apparatus are disclosed to measure the current leakage conducted into a geological formation from within a first cased well that is responsive to fluids injected into formation from a second cased well during the enhanced oil production activities. The current leakage and apparent resistivity measured within the first cased well are responsive to fluids injected into formation from the second cased well provided the distance of separation between the two cased wells is less than, or on the order of, a Characteristic Length appropriate for the problem.

  17. Introducing Innovative Approaches to Learning in Fluid Mechanics: A Case Study

    ERIC Educational Resources Information Center

    Gynnild, Vidar; Myrhaug, Dag; Pettersen, Bjornar

    2007-01-01

    The purpose of the current article is to examine the impact of laboratory demonstrations and computer visualizations on learning in a third-year fluid mechanics course at Norwegian University of Science and Technology (NTNU). As a first step, on entering the course, students were exposed to a laboratory demonstration focusing on the nature of…

  18. Use of Facebook in Teaching: A Case Study of a Fluid Mechanics Course

    ERIC Educational Resources Information Center

    Mandavgane, Sachin A.

    2016-01-01

    Fluid mechanics (FM) is a core course of the chemical, mechanical, civil, and aerospace engineering programs. Students have both theory and practical classes in FM. The general expectation is that students should be able to demonstrate the fundamentals learnt in theory and get hands-on experience during the lab course. In this regard, students…

  19. Amniotic fluid and maternal serum levels of CA125 in pregnancies affected by Down syndrome: a re-evaluation of the role of CA125 in Down syndrome screening.

    PubMed

    Spencer, K; Muller, F; Aitken, D A

    1997-08-01

    In a study of amniotic fluid from 91 Down syndrome cases and 240 controls, we have shown that the median value of CA125 in pregnancies affected by Down syndrome on the whole reflects those observed in the maternal serum from 106 affected cases and 238 controls. The median MOM for CA125 in amniotic fluid from Down syndrome pregnancies was 1.04 and in maternal serum 1.06, neither value being significantly different from that for the control population. We confirm our previous observation that CA125 is not a marker of Down syndrome and conclude that CA125 has no role to play in Down syndrome screening.

  20. Combined measurement of synovial fluid α-Defensin and C-reactive protein levels: highly accurate for diagnosing periprosthetic joint infection.

    PubMed

    Deirmengian, Carl; Kardos, Keith; Kilmartin, Patrick; Cameron, Alexander; Schiller, Kevin; Parvizi, Javad

    2014-09-03

    The diagnosis of periprosthetic joint infection remains a challenge. The purpose of this study was to evaluate the combined measurement of the levels of two synovial fluid biomarkers, α-defensin and C-reactive protein (CRP), for the diagnosis of periprosthetic joint infection. One hundred and forty-nine synovial fluid aspirates, including 112 from patients with an aseptic diagnosis and thirty-seven from patients with periprosthetic joint infection, met the inclusion criteria for this prospective study. Synovial fluid aspirates were tested for α-defensin and CRP levels with use of enzyme-linked immunosorbent assay (ELISA). The Musculoskeletal Infection Society (MSIS) definition of periprosthetic joint infection was utilized for the classification of cases as aseptic or infected. Comorbidities, such as inflammatory conditions, that could confound a test for periprosthetic joint infection were documented, but the patients with such comorbidities were included in the study. The combination of synovial fluid α-defensin and CRP tests demonstrated a sensitivity of 97% and a specificity of 100% for the diagnosis of periprosthetic joint infection. Synovial fluid α-defensin tests alone demonstrated a sensitivity of 97% and a specificity of 96% for the diagnosis of periprosthetic joint infection. Synovial fluid CRP tests, with a low threshold of 3 mg/L, reversed all-false positive α-defensin results without affecting the sensitivity of the test. The diagnostic characteristics of these assays were achieved in a population of patients demonstrating a 23% rate of systemic inflammatory diseases (in the series as a whole) and a 27% rate of concurrent antibiotic treatment (in the infection group). The synovial fluid levels of α-defensin in the setting of periprosthetic joint infection were unchanged during concurrent antibiotic treatment. The combined measurement of synovial fluid α-defensin and CRP levels correctly diagnosed 99% of the cases in this study as aseptic or infected. This was achieved despite the inclusion of patients with systemic inflammatory disease and those receiving treatment with antibiotics. Diagnostic Level II. See Instructions for Authors for a complete description of levels of evidence. Copyright © 2014 by The Journal of Bone and Joint Surgery, Incorporated.

  1. BILATERAL SEROUS MACULAR DETACHMENT IN A PATIENT WITH NEPHROTIC SYNDROME.

    PubMed

    Bilge, Ayse D; Yaylali, Sevil A; Yavuz, Sara; Simsek, İlke B

    2018-01-01

    The purpose of this study was to report a case of a woman with nephrotic syndrome who presented with blurred vision because of bilateral serous macular detachment. Case report and literature review. A 55-year-old woman with a history of essential hypertension, diabetes, and nephrotic syndrome was presented with blurred vision in both eyes. Her fluorescein angiography revealed dye leakage in the early and subretinal pooling in the late phases, and optical coherence tomography scans confirmed the presence of subretinal fluid in the subfovel area. In nephrotic syndrome cases especially with accompaniment of high blood pressure, fluid accumulation in the retina layer may occur. Serous macular detachment must be kept in mind when treating these patients.

  2. Identity and Its Construal: Learning from Luxembourg.

    PubMed

    Murdock, Elke

    2017-06-01

    This article examines national identity construal processes within the case study context of Luxembourg. Building on research highlighting the modalities of generalization from case studies, I present the country case that is Luxembourg. This social universe has a foreign population percentage of 47% and what is considered majority and minority becomes increasingly fluid. The migration process itself is fluid, ranging from daily migration, to medium-term stays, return visits and permanent immigration including uptake of citizenship. Within such a fluid environment, where national borders are permeable at the physical level of crossing borders and (national) societies are nested within societies, culture contact is a permanent feature in daily life. Nationality becomes a salient feature as culture contact tends to prompt reflection, resulting in questioning and (re-)negotiation of national identity. This affects the native population as well as the diverse immigrant population - with diversity going beyond the level of country of origin. Many individuals are also of mixed nationality and some examples for the construal process of national identity will be provided, illustrating how national identity is negotiated at individual level. Like a periscope, this country let s us adjust mirrors, permitting us to observe modes of identity construal which would otherwise be obstructed from the field of view. The case study that is Luxembourg allows us to look at the micro-setting of the construction, potentially of something new.

  3. Heat transfer direction dependence of heat transfer coefficients in annuli

    NASA Astrophysics Data System (ADS)

    Prinsloo, Francois P. A.; Dirker, Jaco; Meyer, Josua P.

    2018-04-01

    In this experimental study the heat transfer phenomena in concentric annuli in tube-in-tube heat exchangers at different annular Reynolds numbers, annular diameter ratios, and inlet fluid temperatures using water were considered. Turbulent flow with Reynolds numbers ranging from 15,000 to 45,000, based on the average bulk fluid temperature was tested at annular diameter ratios of 0.327, 0.386, 0.409 and 0.483 with hydraulic diameters of 17.00, 22.98, 20.20 and 26.18 mm respectively. Both heated and cooled annuli were investigated by conducting tests at a range of inlet temperatures between 10 °C to 30 °C for heating cases, and 30 °C to 50 °C for cooling cases. Of special interest was the direct measurement of local wall temperatures on the heat transfer surface, which is often difficult to obtain and evasive in data-sets. Continuous verification and re-evaluation of temperatures measurements were performed via in-situ calibration. It is shown that inlet fluid temperature and the heat transfer direction play significant roles on the magnitude of the heat transfer coefficient. A new adjusted Colburn j-factor definition is presented to describe the heating and cooling cases and is used to correlate the 894 test cases considered in this study.

  4. Role of Spiral and Multislice Computed Tomography in the evaluation of traumatic and spontaneous oesophageal perforation. Our experience.

    PubMed

    De Lutio di Castelguidone, Elisabetta; Pinto, Antonio; Merola, Stefanella; Stavolo, Ciro; Romano, Luigia

    2005-03-01

    To assess the role CT in the evaluation of traumatic and spontaneous oesophageal perforation. From March 2001 to May 2003, we studied 12 patients (7 males and 5 females; age range: 25-66 years, mean age: 43.5 years) with suspected oesophageal perforation due to motor-vehicle accidents (4 cases), stab wound (one case), post-intubation (2 cases), foreign body ingestion (2 cases) and spontaneous (3 cases). Five patients underwent standard chest and cervical radiography; two patients with suspected foreign body ingestion also underwent a gastrografin swallow study; all of the 12 patients underwent CT of the neck, chest and abdomen before and after intravenous, and in four cases oral, administration of contrast material. In 5 patients with cervical, thoracic and abdominal trauma, the CT examination showed the presence of pleuroparenchymal injury (pneumothorax, pleural effusion and subcutaneous emphysema) as well as findings suggestive of oesophageal perforation: peri-oesophageal air (5 cases), peri-oesophageal fluid (4 cases), oesophageal wall thickening (3 cases), oesophageal wall laceration (2 cases) with abnormal course of the nasogastric tube in one of them and extraluminal extravasation of oral contrast material (2 cases). In 2 patients with post-intubation complications, CT showed the presence of a small peri-oesophageal fluid collection containing small gas bubbles in one case, and a gross perioesophageal abscess-like collection in the second case. In the 2 patients with foreign body ingestion, the plain radiography associated with CT showed the presence of a thin metal object in the cervical region (fragment of a dental plate) and a small extraluminal extravasation of gastrografin in one case, whereas in the other case CT showed the presence of a foreign body (chicken bone) in the hypopharynx with oesophageal wall thickening and peri-oesophageal oedema. In the remaining three patients with suspected spontaneous oesophageal perforation, CT showed the presence of a intramural haematoma in one case, oesophageal fluid distension with gas and a small peri-oesophageal fluid effusion (Mallory-Weiss syndrome) in another, and oesophageal rupture (Boerhaave syndrome) in the last case. Our experience shows that in patients with suspected traumatic and spontaneous oesophageal perforation, standard cervical and chest radiography may suggest a suspected oesophageal perforation in only a small proportion of cases, whereas oral contrast oesophagography has a higher sensitivity. Through the careful analysis of suggestive and specific signs of oesophageal perforation, a correct CT examination enables an accurate and timely diagnosis which significantly affects prognosis and provides valuable indications for treatment.

  5. [Neonatal facial palsy: identification of herpes simplex virus 1 in cerebrospinal fluid. Case report].

    PubMed

    Lubián López, Simón; Pérez Guerrero, Juan J; Salazar Oliva, Patricia; Benavente Fernández, Isabel

    2018-06-01

    Neonatal facial palsy is very uncommon and is generally diagnosed at birth. We present the first published case of neonatal facial palsy with identification of herpes simplex virus 1 in cerebrospinal fluid. A 35-day-old male was presented at the Emergency Department with mouth deviation to the left and impossibility of full closure of the right eye. There were no symptoms of infection or relevant medical history. Physical examination was compatible with peripheral facial palsy. Studies performed at admission were normal (blood count, biochemical analysis and coagulation blood tests and cerebrospinal fluid analysis). The patient was admitted on oral prednisolone and intravenous aciclovir. Cranial magnetic resonance was normal. Polymerase chain reaction test for herpes simplex virus 1 in cerebrospinal fluid was reported positive after 48 hours of admission. Patient followed good evolution and received prednisolone for 7 days and acyclovir for 21 days. At discharge, neurological examination was normal. Sociedad Argentina de Pediatría.

  6. Analytical and numerical study of the electro-osmotic annular flow of viscoelastic fluids.

    PubMed

    Ferrás, L L; Afonso, A M; Alves, M A; Nóbrega, J M; Pinho, F T

    2014-04-15

    In this work we present semi-analytical solutions for the electro-osmotic annular flow of viscoelastic fluids modeled by the Linear and Exponential PTT models. The viscoelastic fluid flows in the axial direction between two concentric cylinders under the combined influences of electrokinetic and pressure forcings. The analysis invokes the Debye-Hückel approximation and includes the limit case of pure electro-osmotic flow. The solution is valid for both no slip and slip velocity at the walls and the chosen slip boundary condition is the linear Navier slip velocity model. The combined effects of fluid rheology, electro-osmotic and pressure gradient forcings on the fluid velocity distribution are also discussed. Copyright © 2013 Elsevier Inc. All rights reserved.

  7. Space station integrated propulsion and fluid systems study

    NASA Technical Reports Server (NTRS)

    Bicknell, B.; Wilson, S.; Dennis, M.; Shepard, D.; Rossier, R.

    1988-01-01

    The program study was performed in two tasks: Task 1 addressed propulsion systems and Task 2 addressed all fluid systems associated with the Space Station elements, which also included propulsion and pressurant systems. Program results indicated a substantial reduction in life cycle costs through integrating the oxygen/hydrogen propulsion system with the environmental control and life support system, and through supplying nitrogen in a cryogenic gaseous supercritical or subcritical liquid state. A water sensitivity analysis showed that increasing the food water content would substantially increase the amount of water available for propulsion use and in all cases, the implementation of the BOSCH CO2 reduction process would reduce overall life cycle costs to the station and minimize risk. An investigation of fluid systems and associated requirements revealed a delicate balance between the individual propulsion and fluid systems across work packages and a strong interdependence between all other fluid systems.

  8. Parametric electroconvection in a weakly conducting fluid in a horizontal parallel-plate capacitor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kartavykh, N. N.; Smorodin, B. L., E-mail: bsmorodin@yandex.ru; Il’in, V. A.

    2015-07-15

    We study the flows of a nonuniformly heated weakly conducting fluid in an ac electric field of a horizontal parallel-plate capacitor. Analysis is carried out for fluids in which the charge formation is governed by electroconductive mechanism associated with the temperature dependence of the electrical conductivity of the medium. Periodic and chaotic regimes of fluid flow are investigated in the limiting case of instantaneous charge relaxation and for a finite relaxation time. Bifurcation diagrams and electroconvective regimes charts are constructed. The regions where fluid oscillations synchronize with the frequency of the external field are determined. Hysteretic transitions between electroconvection regimesmore » are studied. The scenarios of transition to chaotic oscillations are analyzed. Depending on the natural frequency of electroconvective system and the external field frequency, the transition from periodic to chaotic oscillations can occur via quasiperiodicity, a subharmonic cascade, or intermittence.« less

  9. A theoretical study of fluid forces on a centrifugal impeller rotating and whirling in a vaned diffuser

    NASA Technical Reports Server (NTRS)

    Tsujimoto, Yoshinobu; Acosta, Allan J.; Yoshida, Yoshiki

    1989-01-01

    The fluid forces on a centrifugal impeller rotating and whirling in a vaned diffuser are analyzed on the assumption that the number of impeller and diffuser vanes is so large that the flows are perfectly guided by the vanes. The flow is taken to be two dimensional, inviscid, and incompressible, but the effects of impeller and diffuser losses are taken into account. It is shown that the interaction with the vaned diffuser may cause destabilizing fluid forces. From these discussions, it is found that the whirling forces are closely related to the steady head-capacity characteristics of the impeller. This physical understanding of the whirling forces can be applied also to the cases with volute casings. At partial capacities, it is shown that the impeller forces change greatly when the flow rate and whirl velocity are near to the impeller or vaned diffuser attributed rotating stall onset capacity, and the stall propagation velocity, respectively. In such cases the impeller forces may become destabilizing for impeller whirl.

  10. Overnight fluid shifts in subjects with and without obstructive sleep apnea

    PubMed Central

    Ding, Ning; Lin, Wei; Zhang, Xi-Long; Ding, Wen-Xiao; Gu, Bing; Ni, Bu-Qing; Zhang, Wei; Zhang, Shi-Jiang

    2014-01-01

    Objective To investigate the characteristics of baseline body fluid content and overnight fluid shifts between non-obstructive sleep apnea (non-OSA) and obstructive sleep apnea (OSA) subjects. Methods A case-controlled study was performed between February 2013 and January 2014, with 36 (18 OSA and 18 non-OSA) outpatients enrolled in this study. Polysomnographic parameters and results of body fluid were compared between the two groups. Results There were no differences in age, weight, and body mass index (BMI) between groups. Compared with the non-OSA group, OSA group had significantly higher neck circumference (NC) and fluid volume shift in the legs. OSA patients had higher left and right leg fluid indices than non-OSA subjects. There were significant correlations between apnoea-hypopnoea index and baseline fluid indices in both legs as well as the reduction in overnight change in both legs fluid volume. The increase in NC was also significantly correlated with the reduction in overnight change in both legs fluid volume, but not with the change in head and neck fluid volume. There were significant correlations between change in NC and increased fluid shifts in head and neck volume. Conclusions OSA patients had a higher baseline fluid content in both legs as compared with non-OSA subjects, which may be the basic factor with regards to fluid shifts in OSA patients. The increase in head and neck fluid shift volume did not directly correlate with the severity of OSA. PMID:25589967

  11. Fluid Extravasation in Shoulder Arthroscopic Surgery: A Systematic Review

    PubMed Central

    Memon, Muzammil; Kay, Jeffrey; Gholami, Arian; Simunovic, Nicole; Ayeni, Olufemi R.

    2018-01-01

    Background: Arthroscopic surgery of the shoulder joint has become increasingly more common given its advantages over open surgery; however, one rare but potentially life-threatening complication is fluid extravasation into the surrounding tissues, causing edema, respiratory compromise, abnormal results on laboratory blood tests, and possibly death. Currently, no systematic review exists that summarizes the existing clinical research on this topic. Purpose: To perform a systematic review on fluid extravasation as a complication of shoulder arthroscopic surgery, specifically assessing clinical presentation, risk factors, management, and outcomes. Study Design: Systematic review; Level of evidence, 4. Methods: Two reviewers independently searched 3 databases (PubMed, Ovid [MEDLINE], and Embase) from database inception until July 1, 2017. The PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) checklist guided the reporting and data abstraction. The methodological quality of these studies was assessed using the Methodological Index for Non-Randomized Studies (MINORS) checklist. The results are presented in a narrative summary fashion using descriptive statistics including ranges and agreement statistics. Results: A total of 26 studies (20 case reports, 4 case series, and 2 prospective comparative studies) encompassing 205 patients (mean age, 50.8 years [range, 15-83 years]) were included. The most common signs of fluid extravasation included chest wall swelling (n = 86) and neck swelling (n = 116). In 32 patients, observation alone was sufficient. Other patients required airway intubation (n = 16), diuretics (n = 7), steroids (n = 1), and percutaneous drainage of fluid (n = 1). Clinical edema resolved after 2 to 48 hours, and patients were discharged 1 to 20 days postoperatively. Serious complications included transfer to the intensive care unit (n = 14), anterior interosseous nerve palsy (n = 4), rhabdomyolysis (n = 1), and death (n = 1). Conclusion: Fluid extravasation has the potential to be a life-threatening complication of shoulder arthroscopic surgery; however, it is most commonly managed nonoperatively, and symptoms typically resolve with no evidence of long-term complications. Intraoperative surgical decisions, such as minimizing the surgical time and volume of irrigation fluid used, may limit fluid extravasation, while careful intraoperative monitoring may facilitate prompt diagnosis and management to optimize patient outcomes. PMID:29785406

  12. Reexamination of Total Fluid Intake and Bladder Cancer in the Health Professionals Follow-Up Study Cohort

    PubMed Central

    Zhou, Jiachen; Smith, Scott; Giovannucci, Edward; Michaud, Dominique S.

    2012-01-01

    It has been hypothesized that high fluid intake may reduce contact time between carcinogens and bladder epithelium and consequently reduce carcinogenesis. Epidemiologic studies examining fluid intake and bladder cancer have been extremely inconsistent, ranging from strong inverse to strong positive associations. The authors reevaluated the association between fluid intake and bladder cancer among 47,909 participants in the prospective Health Professionals Follow-up Study over a period of 22 years. During follow-up (1986–2008), 823 incident bladder cancer cases were diagnosed. Information on fluid intake was collected by using the food frequency questionnaire at baseline and every 4 years thereafter. Cox proportional hazard regression analysis was used to adjust for risk factors for bladder cancer. Total fluid intake was inversely associated with bladder cancer when the analysis was based on the baseline diet (relative risk = 0.76, 95% confidence interval: 0.60, 0.97), comparing the highest total daily fluid intake quintile (>2,531 mL/day) with the lowest quintile (<1,290 mL/day) (Ptrend = 0.01). However, no association was detected when the analysis was based on recent diet or cumulative updated diet. The updated analysis for total fluid intake and bladder cancer was attenuated compared with the original findings from the first 10-year follow-up period. PMID:22355034

  13. A parameter study of the two-fluid solar wind

    NASA Technical Reports Server (NTRS)

    Sandbaek, Ornulf; Leer, Egil; Holzer, Thomas E.

    1992-01-01

    A two-fluid model of the solar wind was introduced by Sturrock and Hartle (1966) and Hartle and Sturrock (1968). In these studies the proton energy equation was integrated neglecting the heat conductive term. Later several authors solved the equations for the two-fluid solar wind model keeping the proton heat conductive term. Methods where the equations are integrated simultaneously outward and inward from the critical point were used. The equations were also integrated inward from a large heliocentric distance. These methods have been applied to cases with low coronal base electron densities and high base temperatures. In this paper we present a method of integrating the two-fluid solar wind equations using an iteration procedure where the equations are integrated separately and the proton flux is kept constant during the integrations. The technique is applicable for a wide range of coronal base densities and temperatures. The method is used to carry out a parameter study of the two-fluid solar wind.

  14. Two-Phase Flow Simulations through Experimentally Studied Porous Media Analogies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Crandall, D.M.; Ahmadi, G.; Smith, D.H.

    2007-07-01

    The amount of CO2 that can be sequestered in deep brine reservoirs is dependant on fluid-fluid-solid interactions within heterogeneous porous media. Displacement of an in-place fluid by a less viscous invading fluid does not displace 100% of the defending fluid, due to capillary and viscous fingering. This has been studied experimentally and numerically with the use of pore-throat flow cells and pore-level models, respectively, in the last two decades. This current work solves the full Navier-Stokes and continuity equations in a random pore-throat geometry using the Volume of Fluid (VOF) method. To verify that the VOF model can be accuratelymore » applied within narrow apertures, qualitative agreement with the well-documented phenomenon of viscous fingering in a Hele-Shaw cell is first presented. While this motion is similar to the fingering observed in geological media, the random structure of rock restricts flow patterns not captured by flow in Hele-Shaw cells. To mimic this heterogeneous natural geometry, a novel experimental flowcell was created. Experiments of constant-rate injection of air into the water saturated model are described. This situation, where a non-wetting, invading fluid displaces a surface-wetting, more-viscous fluid, is known as drainage. As the injection flow rate was increased, a change from stable displacement fronts to dendritic fingering structures was observed, with a corresponding decrease in the fractal dimension of the interface and a decrease in the final saturation of invading air. Predictions of the VOF computational modeling within the same flowcell geometry are then shown to be in good agreement with the experimental results. Percent saturation and the fractal dimension of the invading fluid were calculated from the numerical model and shown to be similar to the experimental findings for air invasion of a watersaturated domain. The fluid properties (viscosity and density) were than varied and the viscosity ratio and capillary number of the fluids were shown to affect the percent of displaced fluid, with lower capillary number and higher viscosity ratio displacing a greater amount of the wetting fluid. Displacement of a non-wetting, in-place fluid by a less viscous, wetting fluid (the case of imbibition; contact angle > 90°) is then studied with the numerical model. The invading fluid is shown to preferentially move into small throats and displace a larger percent of the in-place fluid than observed in the drainage case. The interface was also observed to have a higher fractal dimension, closer to 2. These results highlight the potential for greater fundamental understanding of liquid-gas-solid interactions in heterogeneous, porous media that can be obtained from computational fluid dynamics (CFD). Situations, which are difficult to experimentally study, can be examined with CFD in a manner that more accurately accounts for the geological conditions relevant to CO2 sequestration. This allows for greater accuracy in the prediction of storage capacity within known geological structures. This study shows that as the contact angle between the invading fluid and the defending fluid increase, a greater portion of the porous medium is invaded. Thus, a greater portion of CO2 can be sequestered in reservoirs that are not strongly water wet. Low flow rates are shown to increase the final percent saturation of the invading fluid as well, regardless of wetting conditions.« less

  15. Study of Surface Wave Propagation in Fluid-Saturated Porous Solids.

    NASA Astrophysics Data System (ADS)

    Azcuaga, Valery Francisco Godinez

    1995-01-01

    This study addresses the surface wave propagation phenomena on fluid-saturated porous solids. The analytical method for calculation of surface wave velocities (Feng and Johnson, JASA, 74, 906, 1983) is extended to the case of a porous solid saturated with a wetting fluid in contact with a non-wetting fluid, in order to study a material combination suitable for experimental investigation. The analytical method is further extended to the case of a non-wetting fluid/wetting fluid-saturated porous solid interface with an arbitrary finite surface stiffness. These extensions of the analytical method allows to theoretically study surface wave propagation phenomena during the saturation process. A modification to the 2-D space-time reflection Green's function (Feng and Johnson, JASA, 74, 915, 1983) is introduced in order to simulate the behavior of surface wave signals detected during the experimental investigation of surface wave propagation on fluid-saturated porous solids (Nagy, Appl. Phys. Lett., 60, 2735, 1992). This modification, together with the introduction of an excess attenuation for the Rayleigh surface mode, makes it possible to explain the apparent velocity changes observed on the surface wave signals during saturation. Experimental results concerning the propagation of surface waves on an alcohol-saturated porous glass are presented. These experiments were performed at frequencies of 500 and 800 kHz and show the simultaneous propagation of the two surface modes predicted by the extended analytical method. Finally an analysis of the displacements associated with the different surface modes is presented. This analysis reveals that it is possible to favor the generation of the Rayleigh surface mode or of the slow surface mode, simply by changing the type of transducer used in the generation of surface waves. Calculations show that a shear transducer couples more energy into the Rayleigh mode, whereas a longitudinal transducer couples more energy into the slow surface mode. Experimental results obtained with the modified experimental system show a qualitative agreement with the theoretical predictions.

  16. Fibrin Sealants in Dura Sealing: A Systematic Literature Review

    PubMed Central

    2016-01-01

    Background Fibrin sealants are widely used in neurosurgery to seal the suture line, provide watertight closure, and prevent cerebrospinal fluid leaks. The aim of this systematic review is to summarize the current efficacy and safety literature of fibrin sealants in dura sealing and the prevention/treatment of cerebrospinal fluid leaks. Methods A comprehensive electronic literature search was run in the following databases: Cochrane Database of Systematic Reviews, Cochrane Central Resister of Controlled Trials, clinicaltrials.gov, MEDLINE/PubMed, and EMBASE. Titles and abstracts of potential articles of interest were reviewed independently by 3 of the authors. Results A total of 1006 database records and additional records were identified. After screening for duplicates and relevance, a total of 78 articles were assessed by the investigators for eligibility. Thirty-eight were excluded and the full-text of 40 articles were included in the qualitative synthesis. Seven of these included only safety data and were included in the safety assessment. The remaining 33 articles included findings from 32 studies that enrolled a total of 2935 patients who were exposed to fibrin sealant. Among these 33 studies there were only 3 randomized controlled trials, with the remaining being prospective cohort analysis, case controlled studies, prospective or retrospective case series. One randomized controlled trial, with 89 patients exposed to fibrin sealant, found a greater rate of intraoperative watertight dura closure in the fibrin sealant group than the control group (92.1% versus 38.0%, p<0.001); however, post-operative cerebrospinal fluid leakage occurred in more fibrin sealant than control patients (6.7% versus 2.0%, p>0.05). Other clinical trials evaluated the effect of fibrin sealant in the postoperative prevention of cerebrospinal fluid leaks. These were generally lower level evidence studies (ie, not prospective, randomized, controlled trials) that were not designed or powered to demonstrate a significant advantage to fibrin sealant use. Two small case series studies evaluated the effect of fibrin sealants in persistent cerebrospinal fluid leak treatment, but did not establish firm efficacy conclusions. Specific adverse reports where fibrin sealants were used for dura sealing were limited, with only 8 cases reported in neurosurgical procedures since 1987 and most reporting only a speculative relationship/association with fibrin sealant exposure. Conclusions A major finding of this systematic literature review is that there is a paucity of randomized studies that have evaluated the effectiveness and safety of fibrin sealants in providing intraoperative watertight dura closure and post-operative cerebrospinal fluid leakage. Among the limited studies available, evidence from a single randomized, controlled trial indicates that fibrin sealants provide a higher rate of intraoperative watertight closure of the dura suture line than control, albeit with a higher rate of postoperative cerebrospinal fluid leakage. Evidence from non-randomized, controlled trials suggests that fibrin sealants may be effective in preventing cerebrospinal fluid leaks with an acceptable safety profile. There is a substantial need for randomized, controlled clinical trials or well-designed prospective observational trials where the conduct of a randomized trial is not feasible to fully assess the impact of fibrin sealant utilization on the rates of intraoperative dura closure, postoperative cerebrospinal leakage, and safety. PMID:27119993

  17. Fibrin Sealants in Dura Sealing: A Systematic Literature Review.

    PubMed

    Esposito, Felice; Angileri, Filippo Flavio; Kruse, Peter; Cavallo, Luigi Maria; Solari, Domenico; Esposito, Vincenzo; Tomasello, Francesco; Cappabianca, Paolo

    2016-01-01

    Fibrin sealants are widely used in neurosurgery to seal the suture line, provide watertight closure, and prevent cerebrospinal fluid leaks. The aim of this systematic review is to summarize the current efficacy and safety literature of fibrin sealants in dura sealing and the prevention/treatment of cerebrospinal fluid leaks. A comprehensive electronic literature search was run in the following databases: Cochrane Database of Systematic Reviews, Cochrane Central Resister of Controlled Trials, clinicaltrials.gov, MEDLINE/PubMed, and EMBASE. Titles and abstracts of potential articles of interest were reviewed independently by 3 of the authors. A total of 1006 database records and additional records were identified. After screening for duplicates and relevance, a total of 78 articles were assessed by the investigators for eligibility. Thirty-eight were excluded and the full-text of 40 articles were included in the qualitative synthesis. Seven of these included only safety data and were included in the safety assessment. The remaining 33 articles included findings from 32 studies that enrolled a total of 2935 patients who were exposed to fibrin sealant. Among these 33 studies there were only 3 randomized controlled trials, with the remaining being prospective cohort analysis, case controlled studies, prospective or retrospective case series. One randomized controlled trial, with 89 patients exposed to fibrin sealant, found a greater rate of intraoperative watertight dura closure in the fibrin sealant group than the control group (92.1% versus 38.0%, p<0.001); however, post-operative cerebrospinal fluid leakage occurred in more fibrin sealant than control patients (6.7% versus 2.0%, p>0.05). Other clinical trials evaluated the effect of fibrin sealant in the postoperative prevention of cerebrospinal fluid leaks. These were generally lower level evidence studies (ie, not prospective, randomized, controlled trials) that were not designed or powered to demonstrate a significant advantage to fibrin sealant use. Two small case series studies evaluated the effect of fibrin sealants in persistent cerebrospinal fluid leak treatment, but did not establish firm efficacy conclusions. Specific adverse reports where fibrin sealants were used for dura sealing were limited, with only 8 cases reported in neurosurgical procedures since 1987 and most reporting only a speculative relationship/association with fibrin sealant exposure. A major finding of this systematic literature review is that there is a paucity of randomized studies that have evaluated the effectiveness and safety of fibrin sealants in providing intraoperative watertight dura closure and post-operative cerebrospinal fluid leakage. Among the limited studies available, evidence from a single randomized, controlled trial indicates that fibrin sealants provide a higher rate of intraoperative watertight closure of the dura suture line than control, albeit with a higher rate of postoperative cerebrospinal fluid leakage. Evidence from non-randomized, controlled trials suggests that fibrin sealants may be effective in preventing cerebrospinal fluid leaks with an acceptable safety profile. There is a substantial need for randomized, controlled clinical trials or well-designed prospective observational trials where the conduct of a randomized trial is not feasible to fully assess the impact of fibrin sealant utilization on the rates of intraoperative dura closure, postoperative cerebrospinal leakage, and safety.

  18. Direct Detection and Identification of Prosthetic Joint Infection Pathogens in Synovial Fluid by Metagenomic Shotgun Sequencing.

    PubMed

    Ivy, Morgan I; Thoendel, Matthew J; Jeraldo, Patricio R; Greenwood-Quaintance, Kerryl E; Hanssen, Arlen D; Abdel, Matthew P; Chia, Nicholas; Yao, Janet Z; Tande, Aaron J; Mandrekar, Jayawant N; Patel, Robin

    2018-05-30

    Background: Metagenomic shotgun sequencing has the potential to transform how serious infections are diagnosed by offering universal, culture-free pathogen detection. This may be especially advantageous for microbial diagnosis of prosthetic joint infection (PJI) by synovial fluid analysis, since synovial fluid cultures are not universally positive, and synovial fluid is easily obtained pre-operatively. We applied a metagenomics-based approach to synovial fluid in an attempt to detect microorganisms in 168 failed total knee arthroplasties. Results: Genus- and species-level analysis of metagenomic sequencing yielded the known pathogen in 74 (90%) and 68 (83%) of the 82 culture-positive PJIs analyzed, respectively, with testing of two (2%) and three (4%) samples, respectively, yielding additional pathogens not detected by culture. For the 25 culture-negative PJIs tested, genus- and species-level analysis yielded 19 (76%) and 21 (84%) samples with insignificant findings, respectively, and 6 (24%) and 4 (16%) with potential pathogens detected, respectively. Genus- and species-level analysis of the 60 culture-negative aseptic failure cases yielded 53 (88.3%) and 56 (93.3%) cases with insignificant findings, and 7 (11.7%) and 4 (6.7%) with potential clinically-significant organisms detected, respectively. There was one case of aseptic failure with synovial fluid culture growth; metagenomic analysis showed insignificant findings, suggesting possible synovial fluid culture contamination. Conclusion: Metagenomic shotgun sequencing can detect pathogens involved in PJI when applied to synovial fluid and may be particularly useful for culture-negative cases. Copyright © 2018 American Society for Microbiology.

  19. Alternative experiments using the geophysical fluid flow cell

    NASA Technical Reports Server (NTRS)

    Hart, J. E.

    1984-01-01

    This study addresses the possibility of doing large scale dynamics experiments using the Geophysical Fluid Flow Cell. In particular, cases where the forcing generates a statically stable stratification almost everywhere in the spherical shell are evaluated. This situation is typical of the Earth's atmosphere and oceans. By calculating the strongest meridional circulation expected in the spacelab experiments, and testing its stability using quasi-geostrophic stability theory, it is shown that strongly nonlinear baroclinic waves on a zonally symmetric modified thermal wind will not occur. The Geophysical Fluid Flow Cell does not have a deep enough fluid layer to permit useful studies of large scale planetary wave processes arising from instability. It is argued, however, that by introducing suitable meridional barriers, a significant contribution to the understanding of the oceanic thermocline problem could be made.

  20. A Case Study Framework for Community College Leaders

    ERIC Educational Resources Information Center

    Nevarez, Carlos; Wood, J. Luke

    2012-01-01

    This article examines a case study framework designed to aid in the preparation of emerging community college leaders. The framework is multidimensional and fluid in nature, taking into account the multiplicity of factors affecting leadership in community colleges. The steps in the framework consist of (a) assuming the role of the leader; (b)…

  1. ESL and Digital Video Integration: Case Studies

    ERIC Educational Resources Information Center

    Li, J., Ed.; Gromik, N., Ed.; Edwards, N., Ed.

    2013-01-01

    It should come as no surprise that digital video technology is of particular interest to English language learners; students are drawn to its visual appeal and vibrant creative potential. The seven original case studies in this book demonstrate how video can be an effective and powerful tool to create fluid, fun, interactive, and collaborative…

  2. [Forensic medical characteristic of the thermal injury caused by inflammation of combustible fluids].

    PubMed

    Khushkadamov, Z K; Iskhizova, L N; Gornostaev, D V

    2012-01-01

    The diagnostics of thermal injuries caused by inflammation of combustible fluids should be based on the comprehensive assessment of the results of examination of the scene of the accident, autopsy studies, forensic chemical expertise, and analysis of the circumstances of the case and/or medical documentation. Special attention should be given to the choice of adequate methods for taking samples to be used in forensic chemical studies. The assessment of thermal injuries caused by inflammation of combustible fluids must take into consideration the time and conditions under which they were inflicted (e.g. closed or open space, vertical or horizontal position, etc.).

  3. Stability of flow of a thermoviscoelastic fluid between rotating coaxial circular cylinders

    NASA Technical Reports Server (NTRS)

    Ghandour, N. N.; Narasimhan, M. N. L.

    1976-01-01

    The stability problem of thermoviscoelastic fluid flow between rotating coaxial cylinders is investigated using nonlinear thermoviscoelastic constitutive equations due to Eringen and Koh. The velocity field is found to be identical with that of the classical viscous case and the case of the viscoelastic fluid, but the temperature and pressure fields are found to be different. By imposing some physically reasonable mechanical and geometrical restrictions on the flow, and by a suitable mathematical analysis, the problem is reduced to a characteristic value problem. The resulting problem is solved and stability criteria are obtained in terms of critical Taylor numbers. In general, it is found that thermoviscoelastic fluids are more stable than classical viscous fluids and viscoinelastic fluids under similar conditions.

  4. Designing shear-thinning

    NASA Astrophysics Data System (ADS)

    Nelson, Arif Z.; Ewoldt, Randy H.

    2017-11-01

    Design in fluid mechanics often focuses on optimizing geometry (airfoils, surface textures, microfluid channels), but here we focus on designing fluids themselves. The dramatically shear-thinning ``yield-stress fluid'' is currently the most utilized non-Newtonian fluid phenomenon. These rheologically complex materials, which undergo a reversible transition from solid-like to liquid-like fluid flow, are utilized in pedestrian products such as paint and toothpaste, but also in emerging applications like direct-write 3D printing. We present a paradigm for yield-stress fluid design that considers constitutive model representation, material property databases, available predictive scaling laws, and the many ways to achieve a yield stress fluid, flipping the typical structure-to-rheology analysis to become the inverse: rheology-to-structure with multiple possible materials as solutions. We describe case studies of 3D printing inks and other flow scenarios where designed shear-thinning enables performance remarkably beyond that of Newtonian fluids. This work was supported by Wm. Wrigley Jr. Company and the National Science Foundation under Grant No. CMMI-1463203.

  5. Application of PBL in the Course Fluid and Electrical Drive Systems, Case Study: Manufacturing an Automated Punch Machine

    ERIC Educational Resources Information Center

    Sedaghat, Ahmad; AlJundub, Mohammad; Eilaghi, Armin; Bani-Hani, Ehab; Sabri, Farhad; Mbarki, Raouf; Assad, M. El Haj

    2017-01-01

    The PBL unit of fluid and electrical drive systems is taught in final semester of undergraduates in mechanical engineering department of the Australian College of Kuwait (ACK). The recent project on an automated punching machine is discovered more appealing to both students and instructors in triggering new ideas and satisfaction end results. In…

  6. Influence of patchy saturation on seismic dispersion and attenuation in fractured porous media

    NASA Astrophysics Data System (ADS)

    Jinwei, Zhang; Handong, Huang; Chunhua, Wu; Sheng, Zhang; Gang, Wu; Fang, Chen

    2018-04-01

    Wave induced fluid flow due to mesoscopic heterogeneity can explain seismic dispersion and attenuation in the seismic frequency band. The mesoscopic heterogeneity mainly contains lithological variations, patchy saturation and mesoscopic fractures. The patchy saturation models which are locally based on Biot theory for porous media have been deeply studied, but the patchy saturation model for fractured porous media is rarely studied. In this paper, we develop a model to describe the poroelastic characteristics in fractured porous media where the background and fractures are filled with different fluids based on two scales of squirt flow. The seismic dispersion and attenuation in fractured porous media occur in two scales, the microscale due to fluid flow between pores and micro-cracks and mesoscale due to fluid flow between background and heterogeneities. We derive the complex stiffness tensor through the solution of stress equivalence and fluid conservation. Two new parameters embodying the fluid effects are introduced into the model compared with the single fluid phase model. The model is consistent with Gassmann-Wood equation at low frequency limit and consistent with the isolated fracture model at high frequency limit. After the frequency dependent stiffness tensor is obtained, the variations of velocities and inverse quality factors with frequency are analyzed through several numerical examples. We investigated three poroelastic cases: medium including pores and micro-cracks, media including pores, micro-cracks and fractures, media including pores and fractures. The frequency dependent characteristics of patchy saturation model are different with those of single fluid model not only in characteristic frequency but also in the magnitude of the attenuation. Finally, we discuss the results obtained and the special case where the fractures are saturated with gas or dry and the background is filled with water. We also compare our results with those of patchy saturation model and double porosity model. The results will contribute to the actual exploration work to a certain extent, such as the fluid identification in fractured reservoirs.

  7. Influence of patchy saturation on seismic dispersion and attenuation in fractured porous media

    NASA Astrophysics Data System (ADS)

    Zhang, Jinwei; Huang, Handong; Wu, Chunhua; Zhang, Sheng; Wu, Gang; Chen, Fang

    2018-07-01

    Wave-induced fluid flow due to mesoscopic heterogeneity can explain seismic dispersion and attenuation in the seismic frequency band. The mesoscopic heterogeneity mainly contains lithological variations, patchy saturation and mesoscopic fractures. The patchy saturation models which are locally based on Biot theory for porous media have been deeply studied, but the patchy saturation model for fractured porous media is rarely studied. In this paper, we develop a model to describe the poroelastic characteristics in fractured porous media where the background and fractures are filled with different fluids based on two scales of squirt flow. The seismic dispersion and attenuation in fractured porous media occur in two scales, the microscale due to fluid flow between pores and microcracks and mesoscale due to fluid flow between background and heterogeneities. We derive the complex stiffness tensor through the solution of stress equivalence and fluid conservation. Two new parameters embodying the fluid effects are introduced into the model compared with the single fluid phase model. The model is consistent with Gassmann-Wood equation at low-frequency limit and consistent with the isolated fracture model at high-frequency limit. After the frequency-dependent stiffness tensor is obtained, the variations of velocities and inverse quality factors with frequency are analysed through several numerical examples. We investigated three poroelastic cases: medium including pores and microcracks; media including pores, microcracks and fractures; media including pores and fractures. The frequency-dependent characteristics of patchy saturation model are different with those of single fluid model not only in characteristic frequency but also in the magnitude of the attenuation. Finally, we discuss the results obtained and the special case where the fractures are saturated with gas or dry and the background is filled with water. We also compare our results with those of patchy saturation model and double porosity model. The results will contribute to the actual exploration work to a certain extent, such as the fluid identification in fractured reservoirs.

  8. Postoperative nausea and vomiting after unrestricted clear fluids before day surgery: A retrospective analysis.

    PubMed

    McCracken, Graham C; Montgomery, Jane

    2018-05-01

    Guidance on pre-operative fluids fasting policy continues to evolve. Current European guidelines encourage the intake of oral fluids up to 2 h before the induction of general anaesthesia. From October 2014, Torbay Hospital Day Surgery Unit commenced an unrestricted fluid policy, encouraging patients to drink clear fluids up until the time of transfer to theatre. The aim of this study was to assess the incidence of postoperative nausea and vomiting before and after the change to the unrestricted pre-operative clear oral fluids. Retrospective, before and after study. Single district general hospital between November 2013 and February 2016. A total of 11 500 patients on the day case pathway who were receiving either sedation, general anaesthesia, regional anaesthesia or their combination. The data from these patients were collected routinely. This number of patients represents approximately 78% of all patients before the change in fluids policy and 74% after the change. Exclusions were patients undergoing a termination of pregnancy, or patients undergoing community dental procedures, from whom patient experience data are not collected. Introduction of a change to the day surgery pathway policy permitting unrestricted clear oral fluids preoperatively until transfer to theatre (from October 2014). Incidence of postoperative nausea and vomiting. The rates of nausea within 24 h postoperatively were 270/5192 (5.2%) when patients could not drink within 2 h of surgery, and 179/4724 (3.8%) when patients could drink up until surgery, a relative rate (95% confidence interval) of 0.73 (0.61 to 0.88), P = 0.00074. The corresponding rates of vomiting were 146/5186 (2.8%) and 104/4716 (2.2%), a relative rate (95% confidence interval) of 0.78 (0.61 to 1.00), P = 0.053. Our data suggest that the liberal consumption of clear fluids before the induction of scheduled day case anaesthesia reduced the rates of postoperative nausea and vomiting.

  9. On hydrodynamic phase field models for binary fluid mixtures

    NASA Astrophysics Data System (ADS)

    Yang, Xiaogang; Gong, Yuezheng; Li, Jun; Zhao, Jia; Wang, Qi

    2018-05-01

    Two classes of thermodynamically consistent hydrodynamic phase field models have been developed for binary fluid mixtures of incompressible viscous fluids of possibly different densities and viscosities. One is quasi-incompressible, while the other is incompressible. For the same binary fluid mixture of two incompressible viscous fluid components, which one is more appropriate? To answer this question, we conduct a comparative study in this paper. First, we visit their derivation, conservation and energy dissipation properties and show that the quasi-incompressible model conserves both mass and linear momentum, while the incompressible one does not. We then show that the quasi-incompressible model is sensitive to the density deviation of the fluid components, while the incompressible model is not in a linear stability analysis. Second, we conduct a numerical investigation on coarsening or coalescent dynamics of protuberances using the two models. We find that they can predict quite different transient dynamics depending on the initial conditions and the density difference although they predict essentially the same quasi-steady results in some cases. This study thus cast a doubt on the applicability of the incompressible model to describe dynamics of binary mixtures of two incompressible viscous fluids especially when the two fluid components have a large density deviation.

  10. Particle Swarms in Fractures: Open Versus Partially Closed Systems

    NASA Astrophysics Data System (ADS)

    Boomsma, E.; Pyrak-Nolte, L. J.

    2014-12-01

    In the field, fractures may be isolated or connected to fluid reservoirs anywhere along the perimeter of a fracture. These boundaries affect fluid circulation, flow paths and communication with external reservoirs. The transport of drop like collections of colloidal-sized particles (particle swarms) in open and partially closed systems was studied. A uniform aperture synthetic fracture was constructed using two blocks (100 x 100 x 50 mm) of transparent acrylic placed parallel to each other. The fracture was fully submerged a tank filled with 100cSt silicone oil. Fracture apertures were varied from 5-80 mm. Partially closed systems were created by sealing the sides of the fracture with plastic film. The four boundary conditions study were: (Case 1) open, (Case 2) closed on the sides, (Case 3) closed on the bottom, and (Case 4) closed on both the sides and bottom of the fracture. A 15 μL dilute suspension of soda-lime glass particles in oil (2% by mass) were released into the fracture. Particle swarms were illuminated using a green (525 nm) LED array and imaged with a CCD camera. The presence of the additional boundaries modified the speed of the particle swarms (see figure). In Case 1, enhanced swarm transport was observed for a range of apertures, traveling faster than either very small or very large apertures. In Case 2, swarm velocities were enhanced over a larger range of fracture apertures than in any of the other cases. Case 3 shifted the enhanced transport regime to lower apertures and also reduced swarm speed when compared to Case 2. Finally, Case 4 eliminated the enhanced transport regime entirely. Communication between the fluid in the fracture and an external fluid reservoir resulted in enhanced swarm transport in Cases 1-3. The non-rigid nature of a swarm enables drag from the fracture walls to modify the swarm geometry. The particles composing a swarm reorganize in response to the fracture, elongating the swarm and maintaining its density. Unlike a drop or solid sphere, fracture boundaries do not exclusively decelerate swarm motion but instead produce enhanced swarm transport. Acknowledgments: This material is based upon work supported by the U.S. Department of Energy, Office of Science, Office of Basic Energy Sciences, Geosciences Research Program under Award Number (DE-FG02-09ER16022).

  11. Development of an Evaporation Sub-model and Simulation of Multiple Droplet Impingement in Volume of Fluid Method

    NASA Astrophysics Data System (ADS)

    Potham, Sathya Prasad

    Droplet collision and impingement on a substrate are widely observed phenomenon in many applications like spray injection of Internal Combustion Engines, spray cooling, spray painting and atomizers used in propulsion applications. Existing Lagrangian models do not provide a comprehensive picture of the outcome of these events and may involve model constants requiring experimental data for validation. Physics based models like Volume of Fluid (VOF) method involve no parametric tuning and are more accurate. The aim of this thesis is to extend the basic VOF method with an evaporation sub-model and implement in an open source Computational Fluid Dynamics (CFD) software, OpenFOAM. The new model is applied to numerically study the evaporation of spherical n-heptane droplets impinging on a hot wall at atmospheric pressure and a temperature above the Leidenfrost temperature. An additional vapor phase is introduced apart from the liquid and gas phases to understand the mixing and diffusion of vapor and gas phases. The evaporation model is validated quantitatively and qualitatively with fundamental problems having analytical solutions and published results. The effect of droplet number and arrangement on evaporation is studied by three cases with one (Case 1), two (Case 2) and four (Case 3) droplets impinging on hot wall in film boiling regime at a fixed temperature of wall and a constant non-dimensional distance between droplets. Droplet lift and spread, surface temperature, heat transfer, and evaporation rate are examined. It was observed that more liquid mass evaporated in Case 1 compared to the other cases. Droplet levitation begins early in Case 1 and very high levitation observed was partially due to contraction of its shape from elongated to a more circular form. Average surface temperature was also considerably reduced in Case 1 due to high droplet levitation.

  12. Triple Pancreatic Walled-off Fluid Collections Treated Simultaneously with Endoscopic Transmural Drainage.

    PubMed

    Khalid, Sameen; Abbass, Aamer; Nellis, Eric; Shah, Shashin; Shah, Hiral

    2018-01-09

    Pancreatic pseudocysts and walled-off pancreatic necrosis arise as a complication of pancreatitis. Multiple fluid collections are seen in 5-20% of the patients who have walled-off peripancreatic fluid collections. There is a paucity of data regarding the role of endoscopic transmural drainage in the management of multiple pancreatic fluid collections. In this case report, we present the case of a 72-year-old male with three walled-off pancreatic fluid collections in the setting of acute necrotizing pancreatitis. The patient underwent simultaneous endoscopic ultrasound-assisted cyst gastrostomy and cyst duodenostomy and aggressive irrigation without index endoscopic necrosectomy of the three peripancreatic fluid collections. Significant improvement in the size of the fluid collections was seen on the computed tomography scan, as well as a remarkable immediate clinical improvement after 24 hours of the endoscopic intervention.

  13. Self-propulsion of a spherical electric or magnetic microbot in a polar viscous fluid

    NASA Astrophysics Data System (ADS)

    Felderhof, B. U.

    2015-02-01

    The self-propulsion of a sphere immersed in a polar liquid or ferrofluid is studied on the basis of ferrohydrodynamics. In the electrical case an oscillating charge density located inside the sphere generates an electrical field that polarizes the fluid. The lag of polarization with respect to the electrical field due to relaxation generates a time-independent electrical torque density acting on the fluid, causing it to move. The resulting propulsion velocity of the sphere is calculated in perturbation theory to second order in powers of the charge density.

  14. Equilibrium configurations of a charged fluid around a Kerr black hole

    NASA Astrophysics Data System (ADS)

    Trova, Audrey; Schroven, Kris; Hackmann, Eva; Karas, Vladimír; Kovář, Jiří; Slaný, Petr

    2018-05-01

    Equilibrium configurations of electrically charged perfect fluid surrounding a central rotating black hole endowed with a test electric charge and embedded in a large-scale asymptotically uniform magnetic field are presented. Following our previous studies considering the central black hole to be nonrotating, we show that in the rotating case conditions for the configurations existence change according to the spin of the black hole. We focus our attention on the charged fluid in rigid rotation, which can form toroidal configurations centered in the equatorial plane or the ones hovering above the black hole, along the symmetry axis. We conclude that a nonzero value of spin changes the existence conditions and the morphology of the solutions significantly. In the case of fast rotation, the morphology of the structures is close to an oblate shape.

  15. The transition from natural convection to thermomagnetic convection of a magnetic fluid in a non-uniform magnetic field

    NASA Astrophysics Data System (ADS)

    Szabo, Peter S. B.; Früh, Wolf-Gerrit

    2018-02-01

    Magnetic fluid flow and heat transfer by natural and thermomagnetic convection was studied numerically in a square enclosure. The aim was to investigate the transition from natural convection to thermomagnetic convection by exploring situations where buoyancy and the Kelvin body force would be opposing each other such that the magnetic effects would in some cases be the dominant factor throughout the domain and in other cases only in a part of the fluid. The numerical model coupled the solution of the magnetostatic field equation with the heat and fluid flow equations to simulate the fluid flow under a realistic magnetic field generated by a permanent magnet. The results suggest that the domain of influence over the flow field is largely aligned with the domain of dominance of the respective driving force. The result is that the transition from a single buoyancy-driven convection cell to a single thermomagnetically driven cell is via a two-cell structure and that the local effect on the flow field leads to a global effect on the heat transfer with a minimum of the Nusselt number in the transition region.

  16. Evaluation of plasma, erythrocytes, and bronchoalveolar lavage fluid antioxidant defense system in sulfur mustard-injured patients.

    PubMed

    Jafari, Mahvash; Ghanei, Mostafa

    2010-03-01

    Sulfur mustard (SM) is a strong alkylating agent that causes acute and chronic effects on different organs following exposure. Main late respiratory complications are chronic obstructive pulmonary disease, bronchiectasis, asthma, and bronchiolitis obliterans. It seems that oxidative stress plays a major role in pathogenesis of diseases. This study was undertaken to evaluate the long-term effect of SM on plasma, erythrocytes, and brochoalveolar lavage fluid antioxidant defense system in SM-injured patients. Brochoalveolar lavage fluid, plasma, and erythrocyte samples were taken from 54 patients in the case group exposed to SM and 25 controls with chronic respiratory disease without a history of exposure to SM. Superoxide dismutase, catalase, and glutathione peroxidase activities in lavage fluid, plasma, and erythrocytes were significantly higher in case group. The increased glutathione S-transferase activity in lavage fluid was associated with a depletion of glutathione and an increase of malondialdehyde levels. There was no significant change observed in glutathione reductase activity. The data suggest that oxidative damage might have an important role for patients exposed to SM. SM may induce an oxidative stress response by depleting the antioxidant defense systems and increasing lipid peroxidation in lung cells.

  17. Direct numerical simulation of viscoelastic-fluid-based nanofluid turbulent channel flow with heat transfer

    NASA Astrophysics Data System (ADS)

    Yang, Juan-Cheng; Li, Feng-Chen; Cai, Wei-Hua; Zhang, Hong-Na; Yu, Bo

    2015-08-01

    Our previous experimental studies have confirmed that viscoelastic-fluid-based nanofluid (VFBN) prepared by suspending nanoparticles in a viscoelastic base fluid (VBF, behaves drag reduction at turbulent flow state) can reduce turbulent flow resistance as compared with water and enhance heat transfer as compared with VBF. Direct numerical simulation (DNS) is performed in this study to explore the mechanisms of heat transfer enhancement (HTE) and flow drag reduction (DR) for the VFBN turbulent flow. The Giesekus model is used as the constitutive equation for VFBN. Our previously proposed thermal dispersion model is adopted to take into account the thermal dispersion effects of nanoparticles in the VFBN turbulent flow. The DNS results show similar behaviors for flow resistance and heat transfer to those obtained in our previous experiments. Detailed analyses are conducted for the turbulent velocity, temperature, and conformation fields obtained by DNSs for different fluid cases, and for the friction factor with viscous, turbulent, and elastic contributions and heat transfer rate with conductive, turbulent and thermal dispersion contributions of nanoparticles, respectively. The mechanisms of HTE and DR of VFBN turbulent flows are then discussed. Based on analogy theory, the ratios of Chilton-Colburn factor to friction factor for different fluid flow cases are investigated, which from another aspect show the significant enhancement in heat transfer performance for some cases of water-based nanofluid and VFBN turbulent flows. Project supported by the National Natural Science Foundation of China (Grant No. 51276046), the Specialized Research Fund for the Doctoral Program of Higher Education of China (Grant No. 20112302110020), the China Postdoctoral Science Foundation (Grant No. 2014M561037), and the President Fund of University of Chinese Academy of Sciences, China (Grant No. Y3510213N00).

  18. The wavefield of acoustic logging in a cased-hole with a single casing - Part I: a monopole tool

    NASA Astrophysics Data System (ADS)

    Wang, Hua; Fehler, Michael

    2018-01-01

    The bonding quality of the seal formed by the cement or collapse material between casing and formation rock is critical for the hydraulic isolation of reservoir layers with shallow aquifers, production and environmental safety, and plug and abandonment issues. Acoustic logging is a very good tool for evaluating the condition of the bond between different interfaces. The understanding of the acoustic logging wavefields in wells with single casing is still incomplete. We use a 3-D finite difference method to simulate wireline monopole wavefields in a single cased borehole with different bonding conditions at two locations: (1) between the cement and casing and (2) between the cement and formation. Pressure snapshots and waveforms for different models are shown, which allow us to better understand the wave propagation. Modal dispersion curves and data processing methods such as velocity-time semblance and dispersion analysis facilitate the identification of propagation modes in the different models. We find that the P wave is submerged in the casing modes and the S wave has poor coherency when the cement is replaced with fluid. The casing modes are strong when cement next to the casing is partially or fully replaced with fluid. The amplitude of these casing modes can be used to determine the bonding condition of the interface between casing and cement. However, the limited variation of the amplitude with fluid thickness means that amplitude measurements may lead to an ambiguous interpretation. When the cement next to the formation is partially replaced with fluid, the modes propagate in the combination of steel casing and cement and the velocities are highly dependent on the cement thickness. However, if the cement thickness is large (more than 2/3 of the annulus between casing and rock), the arrival time of the first arrival approximates that of the formation compressional wave when cement is good. It would highly likely that an analyst could misjudge cement quality because the amplitudes of these modes are very small and their arrival times are very near to the formation P arrival time. It is possible to use the amplitude to estimate the thickness of the cement sheath because the variation of amplitude with thickness is strong. While the Stoneley mode (ST1) propagates in the borehole fluid, a slow Stoneley mode (ST2) appears when there is a fluid column in the annulus between the casing and formation rock. The velocity of ST2 is sensitive to the total thickness of the fluid column in the annulus independent of the location of the fluid in the casing annulus. We propose a full waveform method, which includes the utilization of the amplitude of the first arrival and also the velocity of the ST2 wave, to estimate the bonding condition of multiple interfaces. These two measurements provide more information than the current method that uses only the first arrival to evaluate the bonding interfa next to the casing.

  19. Zinc and magnesium ions synergistically inhibit superoxide generation by cultured human neutrophils--a promising candidate formulation for amnioinfusion fluid.

    PubMed

    Uchida, Toshiyuki; Itoh, Hiroaki; Nakamura, Yuki; Kobayashi, Yukiko; Hirai, Kyuya; Suzuki, Kazunao; Sugihara, Kazuhiro; Kanayama, Naohiro; Hiramatsu, Mitsuo

    2010-06-01

    Oligohydramnios is often caused by the premature rupturing of membranes and subsequent intrauterine infections, such as chorioamnionitis, in which event oxidative stress is hypothesized to be closely associated with the damage to the fetal organs. The clinical efficiency of amnioinfusion using warmed saline in cases of premature rupture of membranes is still controversial, especially concerning the prognosis for the fetus. In the present study, we found that human amniotic fluid per se suppresses the release of superoxide from cultured human neutrophils, suggesting an acute or chronic shortage of amniotic fluid in cases of premature rupture of membranes can affect the shielding of intrauterine organs from oxidative stress. The aim of this study was to propose a formula of zinc and magnesium ions in saline for amnioinfusion, by assessing antioxidative activities. A combination of 5 microM zinc and 5mM magnesium in saline synergistically inhibited superoxide production by cultured human neutrophils, equivalent to human amniotic fluid. The intraperitoneal administration of this formula significantly improved the survival rate in a rat model of peritonitis compared to the saline control (46.7% vs. 10%). The combination of these metals with saline may thus be a promising formula for an amnioinfusion fluid with the capacity to protect fetal organs from oxidative stress. Copyright (c) 2010 Elsevier Ireland Ltd. All rights reserved.

  20. Procalcitonin levels in patients with positive blood culture, positive body fluid culture, sepsis, and severe sepsis: a cross-sectional study.

    PubMed

    Yu, Ying; Li, Xia-Xi; Jiang, Ling-Xiao; Du, Meng; Liu, Zhan-Guo; Cen, Zhong-Ran; Wang, Hua; Guo, Zhen-Hui; Chang, Ping

    2016-01-01

    Numerous investigations on procalcitonin (PCT) have been carried out, although few with large sample size. To deal with the complexity of sepsis, an understanding of PCT in heterogeneous clinical conditions is required. Hospitalized patients aged 10-79 years were included in this retrospective and cross-sectional study. PCT tests were assayed within 2 days of blood culture. A total of 2952 cases (from 2538 patients) were enrolled in this study, including 440 cases in the 'positive BC' group, 123 cases in the 'positive body fluid culture' group, and 2389 cases in the 'negative all culture' group. Median PCT values were 4.53 ng/ml, 2.95 ng/ml, and 0.49 ng/ml, respectively. Median PCT values in the gram-negative BC group and gram-positive BC group, respectively, were 6.99 ng/ml and 2.96 ng/ml. Median PCT values in the 'positive hydrothorax culture' group, 'positive ascites culture' group, 'positive bile culture' group, and 'positive cerebrospinal fluid culture' group, respectively, were 1.39 ng/ml, 8.32 ng/ml, 5.98 ng/ml, and 0.46 ng/ml. In all, 357 cases were classified into the 'sepsis' group, 150 of them were classified into the 'severe sepsis' group. Median PCT values were 5.63 ng/ml and 11.06 ng/ml, respectively. PCT could be used in clinical algorithms to diagnose positive infections and sepsis. Different PCT levels could be related to different kinds of microbemia, different infection sites, and differing severity of sepsis.

  1. Feasibility study of a low-energy gamma ray system for measuring quantity and flow rate of slush hydrogen

    NASA Technical Reports Server (NTRS)

    Singh, Jag J.; Shen, Chih-Ping; Sprinkle, Danny R.

    1992-01-01

    As part of a study to demonstrate the suitability of an X-ray or gamma ray probe for monitoring the quality and flow rate of slush hydrogen, mass attenuation coefficients for Cd-109 X- and gamma radiation in five chemical compounds were measured. The Ag-109 K rays were used for water and acetic acid, whereas E3 transition from the first excited state at 87.7 keV in Ag-109 provided the probe radiation for bromobenzene, alpha (exp 2) chloroisodurene, and cetyl bromide. Measurements were made for a single phase (gas, liquid, solid) as well as mixed phases (liquid plus solid) in all cases. It was shown that the mass attenuation coefficient for the selected radiations is independent of the phase of the test fluids or phase ratios in the case of mixed phase fluids. Described here are the procedure and the results for the five fluid systems investigated.

  2. Test of a new heat-flow equation for dense-fluid shock waves.

    PubMed

    Holian, Brad Lee; Mareschal, Michel; Ravelo, Ramon

    2010-09-21

    Using a recently proposed equation for the heat-flux vector that goes beyond Fourier's Law of heat conduction, we model shockwave propagation in the dense Lennard-Jones fluid. Disequilibrium among the three components of temperature, namely, the difference between the kinetic temperature in the direction of a planar shock wave and those in the transverse directions, particularly in the region near the shock front, gives rise to a new transport (equilibration) mechanism not seen in usual one-dimensional heat-flow situations. The modification of the heat-flow equation was tested earlier for the case of strong shock waves in the ideal gas, which had been studied in the past and compared to Navier-Stokes-Fourier solutions. Now, the Lennard-Jones fluid, whose equation of state and transport properties have been determined from independent calculations, allows us to study the case where potential, as well as kinetic contributions are important. The new heat-flow treatment improves the agreement with nonequilibrium molecular-dynamics simulations under strong shock wave conditions, compared to Navier-Stokes.

  3. Robust and general method for determining surface fluid flow boundary conditions in articular cartilage contact mechanics modeling.

    PubMed

    Pawaskar, Sainath Shrikant; Fisher, John; Jin, Zhongmin

    2010-03-01

    Contact detection in cartilage contact mechanics is an important feature of any analytical or computational modeling investigation when the biphasic nature of cartilage and the corresponding tribology are taken into account. The fluid flow boundary conditions will change based on whether the surface is in contact or not, which will affect the interstitial fluid pressurization. This in turn will increase or decrease the load sustained by the fluid phase, with a direct effect on friction, wear, and lubrication. In laboratory experiments or clinical hemiarthroplasty, when a rigid indenter or metallic prosthesis is used to apply load to the cartilage, there will not be any fluid flow normal to the surface in the contact region due to the impermeable nature of the indenter/prosthesis. In the natural joint, on the other hand, where two cartilage surfaces interact, flow will depend on the pressure difference across the interface. Furthermore, in both these cases, the fluid would flow freely in non-contacting regions. However, it should be pointed out that the contact area is generally unknown in advance in both cases and can only be determined as part of the solution. In the present finite element study, a general and robust algorithm was proposed to decide nodes in contact on the cartilage surface and, accordingly, impose the fluid flow boundary conditions. The algorithm was first tested for a rigid indenter against cartilage model. The algorithm worked well for two-dimensional four-noded and eight-noded axisymmetric element models as well as three-dimensional models. It was then extended to include two cartilages in contact. The results were in excellent agreement with the previous studies reported in the literature.

  4. CT colonography after incomplete optical colonoscopy

    PubMed Central

    Theis, Jake; Kim, David H.; Lubner, Meghan G.; del Rio, Alejandro Muñoz; Pickhardt, Perry J.

    2017-01-01

    Purpose To objectively compare the volume, density, and distribution of luminal fluid for same-day oral-contrast-enhanced CTC following incomplete optical colonoscopy (OC) versus deferred CTC on a separate day utilizing a dedicated CTC bowel preparation. Methods HIPAA-compliant, IRB-approved retrospective study compared 103 same-day CTC studies after incomplete OC (utilizing 30 ml oral diatrizoate) against 151 CTC examinations performed on a separate day after failed OC using a dedicated CTC bowel preparation (oral magnesium citrate/dilute barium/diatrizoate the evening before). A subgroup of 15 patients who had both same-day CTC and separate-day routine CTC was also identified and underwent separate analysis. CTC exams were analyzed for opacified fluid distribution within the GI tract, as well as density and volume. Data was analyzed utilizing Kruskal-Wallis and Wilcoxon Signed Rank tests. Results Opacified luminal fluid extended to the rectum in 56% (58/103) of same-day CTC versus 100% (151/151) of deferred separate-day CTC (p<0.0001). For same-day CTC, contrast failed to reach the colon in 11% (11/103) and failed to reach the left colon in 26% (27/103). Volumetric colonic fluid segmentation for fluid analysis (successful in 80 same-day and 147 separate-day cases) showed significantly more fluid in the same-day cohort (mean, 227 ml vs. 166 ml; p<0.0001); the actual difference is underestimated due to excluded cases. Mean colonic fluid attenuation was significantly lower in the same-day cohort (545 HU vs. 735 HU; p<0.0001). Similar findings were identified in the smaller cohort with direct intra-patient CTC comparison. Conclusions Dedicated CTC bowel preparation on a separate day following incomplete OC results in a much higher quality examination compared with same-day CTC. PMID:26830606

  5. Non-invasive determination of external forces in vortex-pair-cylinder interactions

    NASA Astrophysics Data System (ADS)

    Hartmann, D.; Schröder, W.; Shashikanth, B. N.

    2012-06-01

    Expressions for the conserved linear and angular momenta of a dynamically coupled fluid + solid system are derived. Based on the knowledge of the flow velocity field, these expressions allow the determination of the external forces exerted on a body moving in the fluid such as, e.g., swimming fish. The verification of the derived conserved quantities is done numerically. The interaction of a vortex pair with a circular cylinder in various configurations of motions representing a generic test case for a dynamically coupled fluid + solid system is investigated in a weakly compressible Navier-Stokes setting using a Cartesian cut-cell method, i.e., the moving circular cylinder is represented by cut cells on a moving mesh. The objectives of this study are twofold. The first objective is to show the robustness of the derived expressions for the conserved linear and angular momenta with respect to bounded and discrete data sets. The second objective is to study the coupled dynamics of the vortex pair and a neutrally buoyant cylinder free to move in response to the fluid stresses exerted on its surface. A comparison of the vortex-body interaction with the case of a fixed circular cylinder evidences significant differences in the vortex dynamics. When the cylinder is fixed strong secondary vorticity is generated resulting in a repeating process between the primary vortex pair and the cylinder. In the neutrally buoyant cylinder case, a stable structure consisting of the primary vortex pair and secondary vorticity shear layers stays attached to the moving cylinder. In addition to these fundamental cases, the vortex-pair-cylinder interaction is studied for locomotion at constant speed and locomotion at constant thrust. It is shown that a similar vortex structure like in the neutrally buoyant cylinder case is obtained when the cylinder moves away from the approaching vortex pair at a constant speed smaller than the vortex pair translational velocity. Finally, the idealized symmetric settings are complemented by an asymmetric interaction of a vortex pair and a cylinder. This case is discussed for a fixed and a neutrally buoyant cylinder to show the validity of the derived relations for multi-dimensional body dynamics.

  6. Intraocular cysts of toxoplasma gondii in patients with necrotizing retinitis following periocular/intraocular triamcinolone injection.

    PubMed

    Nijhawan, Raje; Bansal, Reema; Gupta, Nalini; Beke, Nikhil; Kulkarni, Pandurang; Gupta, Amod

    2013-10-01

    To report the detection of Toxoplasma gondii cysts in intraocular aspirates of patients with necrotizing retinitis following periocular/intraocular corticosteroid injection. Case report. Two patients (2 eyes) with widespread necrotizing retinitis in a steroid-exposed eye posed a diagnostic challenge and underwent pars plana vitrectomy (PPV). Intraocular samples (vitreous fluid, retinal tissue, and subretinal aspirate in case 1, and vitreous fluid in case 2) were subjected to cytological examination. The subretinal aspirate (case 1) revealed encysted bradyzoites of Toxoplasma gondii. Vitreous fluid (case 2) tested positive for anti-toxoplasma antibodies and the smear showed encysted forms of Toxoplasma gondii on cytology. CONCLUSION. Toxoplasma gondii cysts were detected in eyes with necrotizing retinitis that developed secondary to injudicious use of corticosteroids.

  7. Effective assessment of egfr mutation status in bronchoalveolar lavage and pleural fluids by next-generation sequencing.

    PubMed

    Buttitta, Fiamma; Felicioni, Lara; Del Grammastro, Maela; Filice, Giampaolo; Di Lorito, Alessia; Malatesta, Sara; Viola, Patrizia; Centi, Irene; D'Antuono, Tommaso; Zappacosta, Roberta; Rosini, Sandra; Cuccurullo, Franco; Marchetti, Antonio

    2013-02-01

    The therapeutic choice for patients with lung adenocarcinoma depends on the presence of EGF receptor (EGFR) mutations. In many cases, only cytologic samples are available for molecular diagnosis. Bronchoalveolar lavage (BAL) and pleural fluid, which represent a considerable proportion of cytologic specimens, cannot always be used for molecular testing because of low rate of tumor cells. We tested the feasibility of EGFR mutation analysis on BAL and pleural fluid samples by next-generation sequencing (NGS), an innovative and extremely sensitive platform. The study was devised to extend the EGFR test to those patients who could not get it due to the paucity of biologic material. A series of 830 lung cytology specimens was used to select 48 samples (BAL and pleural fluid) from patients with EGFR mutations in resected tumors. These samples included 36 cases with 0.3% to 9% of neoplastic cells (series A) and 12 cases without evidence of tumor (series B). All samples were analyzed by Sanger sequencing and NGS on 454 Roche platform. A mean of 21,130 ± 2,370 sequences per sample were obtained by NGS. In series A, EGFR mutations were detected in 16% of cases by Sanger sequencing and in 81% of cases by NGS. Seventy-seven percent of cases found to be negative by Sanger sequencing showed mutations by NGS. In series B, all samples were negative for EGFR mutation by Sanger sequencing whereas 42% of them were positive by NGS. The very sensitive EGFR-NGS assay may open up to the possibility of specific treatments for patients otherwise doomed to re-biopsies or nontargeted therapies.

  8. Contribution of Neonatal Amniotic Fluid Testing to Diagnosis of Congenital Toxoplasmosis

    PubMed Central

    Filisetti, Denis; Villard, Odile; Escande, Benoît; Wafo, Estelle; Houfflin-Debarge, Véronique; Delhaes, Laurence; Bastien, Patrick

    2015-01-01

    We evaluated the molecular diagnosis of congenital toxoplasmosis (CT) on neonatal amniotic fluid samples from 488 mother-child pairs. Maternal infection during pregnancy was diagnosed and dated or could not be ruled out. Forty-six cases of CT were defined according to the European Research Network on CT classification system and case definitions. Neonatal amniotic fluid testing had an overall sensitivity of 54% (95% confidence interval [95% CI], 39 to 69%) and a specificity of 100% (95% CI, 99 to 100%). Its sensitivity was 33% (95% CI, 13 to 59%) when antenatal diagnosis was positive and 68% (95% CI, 48 to 84%) when antenatal diagnosis was negative or lacking. This difference in sensitivity may have been due to treatment of antenatally diagnosed cases. Relative to postnatal serology, neonatal amniotic fluid testing allowed an earlier diagnosis to be made in 26% of the cases (95% CI, 9 to 51%). PMID:25694528

  9. Fluid Extravasation in Shoulder Arthroscopic Surgery: A Systematic Review.

    PubMed

    Memon, Muzammil; Kay, Jeffrey; Gholami, Arian; Simunovic, Nicole; Ayeni, Olufemi R

    2018-05-01

    Arthroscopic surgery of the shoulder joint has become increasingly more common given its advantages over open surgery; however, one rare but potentially life-threatening complication is fluid extravasation into the surrounding tissues, causing edema, respiratory compromise, abnormal results on laboratory blood tests, and possibly death. Currently, no systematic review exists that summarizes the existing clinical research on this topic. To perform a systematic review on fluid extravasation as a complication of shoulder arthroscopic surgery, specifically assessing clinical presentation, risk factors, management, and outcomes. Systematic review; Level of evidence, 4. Two reviewers independently searched 3 databases (PubMed, Ovid [MEDLINE], and Embase) from database inception until July 1, 2017. The PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) checklist guided the reporting and data abstraction. The methodological quality of these studies was assessed using the Methodological Index for Non-Randomized Studies (MINORS) checklist. The results are presented in a narrative summary fashion using descriptive statistics including ranges and agreement statistics. A total of 26 studies (20 case reports, 4 case series, and 2 prospective comparative studies) encompassing 205 patients (mean age, 50.8 years [range, 15-83 years]) were included. The most common signs of fluid extravasation included chest wall swelling (n = 86) and neck swelling (n = 116). In 32 patients, observation alone was sufficient. Other patients required airway intubation (n = 16), diuretics (n = 7), steroids (n = 1), and percutaneous drainage of fluid (n = 1). Clinical edema resolved after 2 to 48 hours, and patients were discharged 1 to 20 days postoperatively. Serious complications included transfer to the intensive care unit (n = 14), anterior interosseous nerve palsy (n = 4), rhabdomyolysis (n = 1), and death (n = 1). Fluid extravasation has the potential to be a life-threatening complication of shoulder arthroscopic surgery; however, it is most commonly managed nonoperatively, and symptoms typically resolve with no evidence of long-term complications. Intraoperative surgical decisions, such as minimizing the surgical time and volume of irrigation fluid used, may limit fluid extravasation, while careful intraoperative monitoring may facilitate prompt diagnosis and management to optimize patient outcomes.

  10. Simultaneous analysis of psychotropic phenylalkylamines in oral fluid by GC-MS with automated SPE and its application to legal cases.

    PubMed

    Choi, Hyeyoung; Baeck, Seungkyung; Jang, Moonhee; Lee, Sooyeun; Choi, Hwakyung; Chung, Heesun

    2012-02-10

    Phenylalkylamine derivatives, such as methamphetamine (MA), amphetamine (AM), 3,4-methylenedioxymethamphetamine (MDMA), 3,4-methylenedioxyamphetamine (MDA), phentermine (PT), fenfluramine (FFA) and phenmetrazine (PM), and ketamine (KT) are widely abused recreational or anorectic drugs in Korea and are regulated under the Controlled Substance Act in Korea. Phenylalkylamines and ketamine analysis is normally performed using both urine and hair samples but there is no established method for the simultaneous analysis of all these phenylalkylamines and ketamine in oral fluids. Oral fluid is easy to collect/handle and can provide an indication of recent drug abuse. In this study, to confirm the presence of phenylalkylamine derivatives and ketamine in oral fluid after screening with an immunoassay, an analytical method using automated solid phase extraction (SPE) and gas chromatography-mass spectrometry (GC-MS) was developed and fully validated according to international guidelines. The applicability of the assay was demonstrated by analyzing of authentic oral fluid samples and the results of oral fluid analysis were compared with those in urine and hair to to evaluate the feasibility of oral fluid in forensic cases. The recovery of phenylalkylamines and ketamine from oral fluid collection devices was also assessed. Oral fluid specimens from 23 drug abuse suspects submitted by the police were collected using Salivette (Sarstedt, Nümbrecht, Germany), Quantisal (Immunalysis, Pomona, CA) or direct expectoration. The samples were screened using a biochip array analyzer (Evidence Investigator, Randox, Antrim, UK). For confirmation, the samples were analyzed by GC-MS in selected-ion monitoring (SIM) mode after extraction using automated SPE (RapidTrace, Zymark, MA, USA) with a mixed-mode cation exchange cartridge (CLEAN SCREEN, 130 mg/3 ml, UCT, PA, USA) and derivatization with trifluoroacetic anhydride (TFA). The results from the immunoassay were consistent with those from GC-MS. Twenty oral fluid samples gave positive results for MA, AM, PT and/or PM among the 23 cases, which gave positive results in urine and/or hair. Although large variations in the MA, AM, PT and PM concentrations were observed in three different specimens, the oral fluid specimen was useful for demonstrating phenylalkylamines and ketamine abuse as an alternative specimen for urine. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  11. Fluid balance and chloride load in the first 24h of ICU admission and its relation with renal replacement therapies through a multicentre, retrospective, case-control study paired by APACHE-II.

    PubMed

    González-Castro, A; Ortiz-Lasa, M; Leizaola, O; Salgado, E; Irriguible, T; Sánchez-Satorra, M; Lomas-Fernández, C; Barral-Segade, P; Cordero-Vallejo, M; Rodrigo-Calabia, E; Dierssen-Sotos, T

    2017-05-01

    To analyse the association between water balance during the first 24h of admission to ICU and the variables related to chloride levels (chloride loading, type of fluid administered, hyperchloraemia), with the development of acute kidney injury renal replacement therapy (AKI-RRT) during patients' admission to ICU. Multicentre case-control study. Hospital-based, national, carried out in 6 ICUs. Cases were patients older than 18 years who developed an AKI-RRT. Controls were patients older than 18 years admitted to the same institutions during the study period, who did not develop AKI-RRT during ICU admission. Pairing was done by APACHE-II. An analysis of unconditional logistic regression adjusted for age, sex, APACHE-II and water balance (in evaluating the type of fluid). We analysed the variables of 430 patients: 215 cases and 215 controls. An increase of 10% of the possibility of developing AKI-RRT per 500ml of positive water balance was evident (OR: 1.09 [95% CI: 1.05 to 1.14]; P<.001). The study of mean values of chloride load administered did not show differences between the group of cases and controls (299.35±254.91 vs. 301.67±234.63; P=.92). The water balance in the first 24h of ICU admission relates to the development of IRA-TRR, regardless of chloraemia. Copyright © 2017 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Publicado por Elsevier España, S.L.U. All rights reserved.

  12. Fluid injection and induced seismicity

    NASA Astrophysics Data System (ADS)

    Kendall, Michael; Verdon, James

    2016-04-01

    The link between fluid injection, or extraction, and induced seismicity has been observed in reservoirs for many decades. In fact spatial mapping of low magnitude events is routinely used to estimate a stimulated reservoir volume. However, the link between subsurface fluid injection and larger felt seismicity is less clear and has attracted recent interest with a dramatic increase in earthquakes associated with the disposal of oilfield waste fluids. In a few cases, hydraulic fracturing has also been linked to induced seismicity. Much can be learned from past case-studies of induced seismicity so that we can better understand the risks posed. Here we examine 12 case examples and consider in particular controls on maximum event size, lateral event distributions, and event depths. Our results suggest that injection volume is a better control on maximum magnitude than past, natural seismicity in a region. This might, however, simply reflect the lack of baseline monitoring and/or long-term seismic records in certain regions. To address this in the UK, the British Geological Survey is leading the deployment of monitoring arrays in prospective shale gas areas in Lancashire and Yorkshire. In most cases, seismicity is generally located in close vicinity to the injection site. However, in some cases, the nearest events are up to 5km from the injection point. This gives an indication of the minimum radius of influence of such fluid injection projects. The most distant events are never more than 20km from the injection point, perhaps implying a maximum radius of influence. Some events are located in the target reservoir, but most occur below the injection depth. In fact, most events lie in the crystalline basement underlying the sedimentary rocks. This suggests that induced seismicity may not pose a leakage risk for fluid migration back to the surface, as it does not impact caprock integrity. A useful application for microseismic data is to try and forecast induced seismicity during injection, with the aim of mitigating large induced events before they happen. Microseismic event population statistics can be used to make forecasts about the future maximum event magnitude as the injection program continues. By making such forecasts, mitigating actions may be possible if forecast maximum magnitudes exceed a predefined limit.

  13. Dynamical pattern formation in a low-concentration magnetorheological fluid under two orthogonal sinusoidal fields

    NASA Astrophysics Data System (ADS)

    Yépez, L. D.; Carrillo, J. L.; Donado, F.; Sausedo-Solorio, J. M.; Miranda-Romagnoli, P.

    2016-06-01

    The dynamical pattern formation of clusters of magnetic particles in a low-concentration magnetorheological fluid, under the influence of a superposition of two perpendicular sinusoidal fields, is studied experimentally. By varying the frequency and phase shift of the perpendicular fields, this configuration enables us to experimentally analyze a wide range of field configurations, including the case of a pure rotating field and the case of an oscillating unidirectional field. The fields are applied parallel to the horizontal plane where the fluid lies or in the vertical plane. For fields applied in the horizontal plane, we observed that, when the ratio of the frequencies increases, the average cluster size exhibits a kind of periodic resonances. When the phase shift between the fields is varied, the average chain length reaches maximal values for the cases of the rotating field and the unidirectional case. We analyze and discuss these results in terms of a weighted average of the time-dependent Mason number. In the case of a rotating field on the vertical plane, we also observe that the competition between the magnetic and the viscous forces determines the average cluster size. We show that this configuration generates a series of physically meaningful self-organization of clusters and transport phenomena.

  14. Bound acoustic modes in the radiation continuum in isotropic layered systems without periodic structures

    NASA Astrophysics Data System (ADS)

    Maznev, A. A.; Every, A. G.

    2018-01-01

    We study the existence of guided acoustic modes in layered structures whose phase velocity is higher than that of bulk waves in a solid substrate or an adjacent fluid half space, which belong to the class of bound states in the radiation continuum (BICs). We demonstrate that in contrast to the electromagnetic case, non-symmetry-protected BICs exist in isotropic layered systems without periodic structures. Two systems supporting non-symmetry-protected sagittally polarized BICs have been identified: (i) a supported solid layer yields BICs whose phase velocity is higher than the transverse velocity of the substrate but lower than the longitudinal velocity; (ii) a supported solid layer loaded by a fluid half space supports BICs whose velocity is higher that the bulk velocity of the fluid but lower than acoustic velocities of the substrate. The latter case is a unique example of BICs in the sense that it does not involve an evanescent field in the fluid half space providing the radiation continuum. In either case, BICs are represented by isolated points in the dispersion relations located within "leaky" branches. We show that these BICs are robust with respect to small perturbations of the system parameters. Numerical results are provided for realistic materials combinations. We also show that no BICs exist in all-fluid layered structures, whereas in solid layered structures there are no shear horizontal BICs and no sagittally polarized BICs whose velocity exceeds the longitudinal velocity of the substrate.

  15. Surface motion of a fluid planet induced by impacts

    NASA Astrophysics Data System (ADS)

    Ni, Sidao; Ahrens, Thomas J.

    2006-10-01

    In order to approximate the free-surface motion of an Earth-sized planet subjected to a giant impact, we have described the excitation of body and surface waves in a spherical compressible fluid planet without gravity or intrinsic material attenuation for a buried explosion source. Using the mode summation method, we obtained an analytical solution for the surface motion of the fluid planet in terms of an infinite series involving the products of spherical Bessel functions and Legendre polynomials. We established a closed form expression for the mode summation excitation coefficient for a spherical buried explosion source, and then calculated the surface motion for different spherical explosion source radii a (for cases of a/R = 0.001 to 0.035, R is the radius of the Earth) We also studied the effect of placing the explosion source at different radii r0 (for cases of r0/R = 0.90 to 0.96) from the centre of the planet. The amplitude of the quasi-surface waves depends substantially on a/R, and slightly on r0/R. For example, in our base-line case, a/R = 0.03, r0/R = 0.96, the free-surface velocity above the source is 0.26c, whereas antipodal to the source, the peak free surface velocity is 0.19c. Here c is the acoustic velocity of the fluid planet. These results can then be applied to studies of atmosphere erosion via blow-off caused by asteroid impacts.

  16. Fluid management of hypernatraemic dehydration to prevent cerebral oedema: a retrospective case control study of 97 children in China.

    PubMed

    Fang, Chengqing; Mao, Jianhua; Dai, Yuwen; Xia, Yonghui; Fu, Haidong; Chen, Yifang; Wang, Yaping; Liu, Aimin

    2010-06-01

    To compare the fluid management of hypernatraemic dehydration in acute gastroenteritis in those who developed cerebral oedema (cases) versus those who did not (controls). A retrospective study of 97 cases of hypernatraemic dehydration at a tertiary children's hospital in China over five years, in which rehydration regimes of 49 children who developed cerebral oedema were compared with 48 children who made an uneventful recovery. Risk factors for cerebral oedema (vs. no cerebral oedema) were an initial fluid bolus (29/49 vs. 15/48, P=0.006), the mean rate of bolus infusion (14.7+/-2.2 vs. 10.8+/-1.4 mL/kg/hr, P<0.001), the severity of hypernatraemia (serum sodium 167.7+/-7.8 vs. 161.3+/-7.9 mmol/L, P<0.001) and the overall rehydration rate (8.2+/-1.1 vs. 6.4+/-0.6 mL/kg/hr, P<0.001). On logistic regression, a rapid rehydration rate was the most significant contributor to cerebral oedema. From receive operating characteristic (ROC) curve analysis, the safe rate of rehydration was <6.8 mL/kg/hr. The key risk factors for the development of cerebral oedema during recovery from hypernatraemic dehydration were too rapid a rate of rehydration, an initial fluid bolus to rapidly expand plasma volume and the severity of the hypernatraemia. Thus, we conclude that a uniformly slow rate of rehydration is the best way of preventing cerebral oedema.

  17. Transport and mixing in strongly coupled dusty plasma medium

    NASA Astrophysics Data System (ADS)

    Dharodi, Vikram; Das, Amita; Patel, Bhavesh

    2016-10-01

    The generalized hydrodynamic (GHD) fluid model has been employed to study the transport and mixing properties of Dusty plasma medium in strong coupling limit. The response of lighter electron and ion species to the dust motion is taken to be instantaneous i.e. inertia-less. Thus the electron and ion density are presumed to follow the Boltzman relation. In the incompressible limit (i-GHD) the model supports Transverse Shear wave in contrast to the Hydrodynamic fluids. It has been shown that the presence of these waves leads to a better mixing of fluid in this case. Several cases of flow configuration have been considered for the study. The transport and mixing attributes have been quantified by studying the dynamical evolution of tracer particles in the system. The diffusion and clustering of these test particles are directly linked to the mixing characteristic of a medium. The displacement of these particles provides for a quantitative estimate of the diffusion coefficient of the medium. It is shown that these test particles often organize themselves in spatially inhomogeneous pattern leading to the phenomena of clustering.

  18. Fluids and sepsis: changing the paradigm of fluid therapy: a case report.

    PubMed

    Hariyanto, Hori; Yahya, Corry Quando; Widiastuti, Monika; Wibowo, Primartanto; Tampubolon, Oloan Eduard

    2017-02-04

    Over the past 16 years, sepsis management has been guided by large-volume fluid administration to achieve certain hemodynamic optimization as advocated in the Rivers protocol. However, the safety of such practice has been questioned because large-volume fluid administration is associated with fluid overload and carries the worst outcome in patients with sepsis. Researchers in multiple studies have declared that using less fluid leads to increased survival, but they did not describe how to administer fluids in a timely and appropriate manner. An 86-year-old previously healthy Sundanese man was admitted to the intensive care unit at our institution with septic shock, acute kidney injury, and respiratory distress. Standard care was implemented during his initial care in the high-care unit; nevertheless, his condition worsened, and he was transferred to the intensive care unit. We describe the timing of fluid administration and elaborate on the amount of fluids needed using a conservative fluid regimen in a continuum of resuscitated sepsis. Because fluid depletion in septic shock is caused by capillary leak and pathologic vasoplegia, continuation of fluid administration will drive intravascular fluid into the interstitial space, thereby producing marked tissue edema and disrupting vital oxygenation. Thus, fluids have the power to heal or kill. Therefore, management of patients with sepsis should entail early vasopressors with adequate fluid resuscitation followed by a conservative fluid regimen.

  19. Cerebrospinal fluid cutaneous fistula following obstetric epidural analgaesia. Case report.

    PubMed

    Fedriani de Matos, J J; Quintero Salvago, A V; Gómez Cortés, M D

    2017-10-01

    Cutaneous fistula of cerebrospinal fluid is a rare complication of neuroaxial blockade. We report the case of a parturient in whom an epidural catheter was placed for labour analgesia and 12h after the catheter was removed, presented an abundant asymptomatic fluid leak from the puncture site, compatible in the cyto-chemical analysis with cerebrospinal fluid. She was treated with acetazolamide, compression of skin orifice of the fluid leakage, antibiotic prophylaxis, hydration and rest, and progressed satisfactorily without requiring blood patch. Copyright © 2017 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Publicado por Elsevier España, S.L.U. All rights reserved.

  20. Cerebrospinal fluid monoamines in Prader-Willi syndrome.

    PubMed

    Akefeldt, A; Ekman, R; Gillberg, C; Månsson, J E

    1998-12-15

    The behavioral phenotype of Prader-Willi syndrome (PWS) suggests hypothalamic dysfunction and altered neurotransmitter regulation. The purpose of this study was to examine whether there was any difference in the concentrations of monoamine metabolites in the cerebrospinal fluid (CSF) in PWS and non-PWS comparison cases. The concentration of monoamine metabolites in CSF was determined in 13 children and adolescents with PWS diagnosed on clinical and genetic criteria. The concentrations were compared with those from 56 comparison cases in healthy and other contrast groups. The concentrations of dopamine and particularly serotonin metabolites were increased in the PWS group. The differences were most prominent for 5-hydroxyindoleacetic acid. The increased concentrations were found in all PWS cases independently of age, body mass index, and level of mental retardation. The findings implicate dysfunction of the serotonergic system and possibly also of the dopamine system in PWS individuals, and might help inform future psychopharmacologic studies.

  1. Gonadotropin level abnormalities in women with cyclic mastalgia.

    PubMed

    Ecochard, R; Marret, H; Rabilloud, M; Boehringer, H; Mathieu, C; Guerin, J F

    2001-01-01

    Women with cyclic mastalgia seem to be at risk of fibrocystic breast disease and/or breast cancer. We studied the relationships between mastalgia and hormone levels throughout the menstrual cycle. Ostensibly healthy women were monitored during a sum of 326 cycles. A case-control study compared personal and hormonal variables of 30 women experiencing cyclic mastalgia with those of 77 women without this symptom. Except sleeping times, no significant differences were found in personal variables. Cyclic mastalgia and symptoms of fluid retention were slightly associated. Menses and the luteal phase were significantly longer in cases than in controls. Gonadotropin but not ovarian hormone levels were also significantly higher in cases throughout the cycle. Cyclic mastalgia is less related to symptoms of fluid retention or to ovarian hormone levels than to regularly high gonadotropin levels, specific inhibitors might thus be used to alleviate the symptom.

  2. Jet meandering by a foil pitching in quiescent fluid

    NASA Astrophysics Data System (ADS)

    Shinde, Sachin Y.; Arakeri, Jaywant H.

    2013-04-01

    The flow produced by a rigid symmetric NACA0015 airfoil purely pitching at a fixed location in quiescent fluid (the limiting case of infinite Strouhal number) is studied using visualizations and particle image velocimetry. A weak jet is generated whose inclination changes continually with time. This meandering is observed to be random and independent of the initial conditions, over a wide range of pitching parameters.

  3. Comparative Assessment of Conventional Papanicolaou and Modified Ultrafast Papanicolaou Stains in Fine Needle Aspiration Samples and Body Fluids.

    PubMed

    Arul, P; Eniya, S; Pushparaj, Magesh; Masilamani, Suresh; Kanmani, P; Lingasamy, C

    2018-01-01

    Conventional Papanicolaou (Pap) stain has undergone many modifications; of these, ultrafast Pap stain is the most popular as it shortens the turnaround time of reporting. Application of modified ultrafast Pap (MUFP) stain in the evaluation of fine needle aspiration (FNA) samples and body fluids are scanty. To evaluate the utility of MUFP stain in various FNA samples and body fluids and compare the findings with those of conventional Pap stain. In this cross-sectional study, two wet-fixed and two airdried smears from each sample [301 samples (255 FNA samples and 46 body fluids)] were prepared and stained by the conventional Pap and MUFP stains, respectively. Concordant and discordant rate was calculated. Quality index (QI) of MUFP stain was assessed by background, overall staining, cell morphology, and nuclear characteristics. MUFP-stained smears were also categorized into excellent, good, and fair. The concordance rate for MUFP stain was 100%. QI of MUFP stain for breast, thyroid, lymph node, soft tissue, salivary gland, and body fluids was 0.9, 0.93, 0.95, 1, 0.94, and 1, respectively. Excellent quality of stain was noted in 53.2% and good in 24.6% of the cases allowing easy diagnosis. In 22.2% of fair cases, diagnosis was possible with some difficulties. Our study concluded that MUFP stain could be considered as a rapid and reliable diagnostic tool and can be applied on a regular basis in FNA samples and body fluids to offer immediate diagnosis. However, caution should be taken while reporting certain MUFP-stained smears to avoid over/under diagnosis.

  4. Prostate cancer incidence in relation to time windows of exposure to metalworking fluids in the auto industry.

    PubMed

    Agalliu, Ilir; Kriebel, David; Quinn, Margaret M; Wegman, David H; Eisen, Ellen A

    2005-09-01

    Exposure to metalworking fluids has been previously associated with prostate cancer mortality in a cohort of autoworkers. Our objective was to further explore this finding in a study of prostate cancer incidence in the same cohort, with reduced misclassification of outcome. We conducted a nested case-control study in the General Motors cohort of autoworkers. Incident cases of prostate cancer (n = 872) were identified via the Michigan Cancer Registry from 1985 through 2000. Controls were selected using incidence-density sampling with 5:1 ratio. Using cumulative exposure (mg/m-years) as the dose metric, we first examined varying lengths of lags (0-25 years). Then, we evaluated consecutive windows of exposure: 25 or more years before risk age, and fewer than 25 years. We used penalized splines to model the relative risk as a smooth function of exposure, and adjusted for race and calendar year of diagnosis in a Cox model. Risk of prostate cancer increased with exposure to soluble and straight fluids 25 years or more before risk age but not with exposure in the last 25 years. The relationship with soluble fluids was piecewise linear, with a small increase in risk at lower exposures followed by a steeper rise. By contrast, the relationship with straight fluids was linear, with a relative risk of 1.12 per 10mg/m-years of exposure (95% confidence interval = 1.04-1.20). Exposure to oil-based fluids, soluble and straight, is modestly associated with prostate cancer risk among autoworkers, with a latency period of at least 25 years.

  5. Ultrasound Thermal Field Imaging of Opaque Fluids

    NASA Technical Reports Server (NTRS)

    Andereck, C. David

    1999-01-01

    We have initiated an experimental program to develop an ultrasound system for non-intrusively imaging the thermal field in opaque fluids under an externally imposed temperature gradient. Many industrial processes involve opaque fluids, such as molten metals, semiconductors, and polymers, often in situations in which thermal gradients are important. For example, one may wish to understand semiconductor crystal growth dynamics in a Bridgman apparatus. Destructive testing of the crystal after the process is completed gives only indirect information about the fluid dynamics of the formation process. Knowledge of the coupled thermal and velocity fields during the growth process is then essential. Most techniques for non-intrusive velocity and temperature measurement in fluids are optical in nature, and hence the fluids studied must be transparent. In some cases (for example, LDV (laser Doppler velocimetry) and PIV (particle imaging velocimetry)) the velocities of small neutrally buoyant seed particles suspended in the fluid, are measured. Without particle seeding one can use the variation of the index of refraction of the fluid with temperature to visualize, through interferometric, Schlieren or shadowgraph techniques, the thermal field. The thermal field in turn gives a picture of the pattern existing in the fluid. If the object of study is opaque, non-optical techniques must be used. In this project we focus on the use of ultrasound, which propagates easily through opaque liquids and solids. To date ultrasound measurements have almost exclusively relied on the detection of sound scattered from density discontinuities inside the opaque material of interest. In most cases it has been used to visualize structural properties, but more recently the ultrasound Doppler velocimeter has become available. As in the optical case, it relies on seed particles that scatter Doppler shifted sound back to the detector. Doppler ultrasound techniques are, however, not useful for studying convective fluid flow in crystal growth, because particle seeding is unacceptable and flow velocities are typically too low to be resolved, and may be even lower in microgravity conditions where buoyancy forces are negligible. We will investigate a different use of ultrasound to probe the flows of opaque fluids non-intrusively and without the use of seed particles: our goal is to ultrasonically visualize the thermal field of opaque fluids with relatively high spatial resolution. The proposed technique relies upon the variation of sound speed with temperature of the fluid. A high frequency ultra-sound pulse passing through a fluid-filled chamber will traverse the chamber in a time determined by the relevant chamber dimension and the temperature of the fluid through which the pulse passes. With high time-resolution instrumentation that compares the excitation signal with the received pulse we can detect the influence of the fluid temperature on the pulse travel time. This is effectively an interferometric system, which in its optical form is an extremely sensitive approach to measuring thermal fields in fluids. Moreover, the temperature dependence of sound velocity in liquid metals is comparable to the temperature dependence of the speed of light required for accurate interferometric thermal images in transparent fluids. With an array of transducers scanned electronically a map of the thermal field over the chamber could be produced. An alternative approach would be to use the ultrasound analog of the shadowgraph technique. In the optical version, collimated light passes through the fluid, where it is focused or defocused locally by temperature field induced variations of the index of refraction. The resulting image reveals the thermal field through the spatial pattern of light intensity variations. By analogy, an ultrasound plane wave traversing an opaque fluid sample would be also locally focused or defocused depending on the speed of sound variations, giving rise to spatial variations in sound intensity that will reveal the thermal field pattern. These approaches could be applied to any situation in which temperature differences are expected to occur, and will rapidly provide information about the flow that simply cannot be obtained by any current intrusive or non-intrusive diagnostic technique. As materials processing in microgravity matures it will become increasingly important to have available simple and versatile diagnostic tools, such as we will develop, for studying the flows of opaque fluids under thermal forcing.

  6. Impedance loading and radiation of finite aperture multipole sources in fluid filled boreholes

    NASA Astrophysics Data System (ADS)

    Geerits, Tim W.; Kranz, Burkhard

    2017-04-01

    In the exploration of oil and gas finite aperture multipole borehole acoustic sources are commonly used to excite borehole modes in a fluid-filled borehole surrounded by a (poro-) elastic formation. Due to the mutual interaction of the constituent sources and their immediate proximity to the formation it has been unclear how and to what extent these effects influence radiator performance. We present a theory, based on the equivalent surface source formulation for fluid-solid systems that incorporates these 'loading' effects and allows for swift computation of the multipole source dimensionless impedance, the associated radiator motion and the resulting radiated wave field in borehole fluid and formation. Dimensionless impedance results are verified through a comparison with finite element modeling results in the cases of a logging while drilling tool submersed in an unbounded fluid and a logging while drilling tool submersed in a fluid filled borehole surrounded by a fast and a slow formation. In all these cases we consider a monopole, dipole and quadrupole excitation, as these cases are relevant to many borehole acoustic applications. Overall, we obtain a very good agreement.

  7. Fourier domain optical coherence tomographic and auto-fluorescence findings in indeterminate choroidal melanocytic lesions.

    PubMed

    Singh, Arun D; Belfort, Rubens N; Sayanagi, Kaori; Kaiser, Peter K

    2010-04-01

    To compare detection rates of drusen and subretinal fluid by Fourier domain optical coherence tomography (FD OCT) and orange pigment by fundus autofluorescence (FAF) with ophthalmoscopy in indeterminate choroidal melanocytic lesions. In a consecutive case series of 38 patients with indeterminate choroidal melanocytic lesion that would have been categorised as a small tumour according to the size-based nomenclature used in the Collaborative Ocular Melanoma Study, each eye was submitted to ophthalmoscopic examination, FD OCT and FAF. The presence of drusen, subretinal fluid and orange pigment was recorded for each lesion by a single observer at the time of initial ophthalmoscopic evaluation and on fundus photographs. FD OCT and autofluorescence images were reviewed in all cases in a masked fashion. The ophthalmoscopic examination revealed drusen in 42%, subretinal fluid in 53% and orange pigment in 50% of patients. FD-OCT detected drusen in 45% and subretinal fluid in 58% of cases, and FAF detected orange pigment in 58% of cases. Based on the McNemar test, none of the differences were statistically significant at the 0.05 level. FD OCT and FAF complement clinical examination by verifying and documenting retinal and RPE changes associated with indeterminate choroidal melanocytic lesions. The detection rates by FD OCT and FAF of important qualitative prognostic factors appear to be equivalent to ophthalmoscopy by a trained observer. Once validated in a larger number of patients, FD OCT and FAF findings can be incorporated into diagnostic algorithms.

  8. [Incidence of Haemophilus influenzae type b meningitis in children under 5 years from Malopolska region in the years 2003-2004--prospective study].

    PubMed

    Konior, Ryszard; Skoczyńska, Anna; Hryniewicz, Waleria

    2008-01-01

    the aim of the study was to establish the incidence of Haemophilus influenzae type b, Hib meningitis in the Malopolska province and to draw attention to the potential need for changing the rules of prophylaxis. a prospective study was carried out among children from the Malopolska province under 5 years with meningitis who were hospitalized between 1 January 2003 and 31 December 2004. All paediatric and infectious diseases wards in 24 hospitals participated in the study. Diagnosis of Hib meningitis was based on symptoms of central nervous system inflammation together with (1) positive culture of Hib from cerebrospinal fluid and/or blood and/or (2) positive latex test identifying Hib in cerebrospinal fluid and/or blood and/or (3) detection of nucleic acid of Hib in cerebrospinal fluid and/or blood. in the studied period 27 cases of H. influenzae meningitis were observed (26 of type b and one case of type f). The incidence of Hib meningitis was as follows: 6.4/100000 children under 5 years, 7.4/100000 children under 4 years and 13.2/100000 children under 2 years. One 3.5-year-old girl died. the study shows a high incidence of Hib meningitis, similar to that in the neighboring EU countries before implementation of wide preventive measures. Cases of suspected vaccination failure should be carefully verified, with specific methods since the number of failures has been shown to be overrated.

  9. Giant intracranial aneurysm embolization with a yield stress fluid material: insights from CFD analysis.

    PubMed

    Wang, Weixiong; Graziano, Francesca; Russo, Vittorio; Ulm, Arthur J; De Kee, Daniel; Khismatullin, Damir B

    2013-01-01

    The endovascular treatment of intracranial aneurysms remains a challenge, especially when the aneurysm is large in size and has irregular, non-spherical geometry. In this paper, we use computational fluid dynamics to simulate blood flow in a vertebro-basilar junction giant aneurysm for the following three cases: (1) an empty aneurysm, (2) an aneurysm filled with platinum coils, and (3) an aneurysm filled with a yield stress fluid material. In the computational model, blood and the coil-filled region are treated as a non-Newtonian fluid and an isotropic porous medium, respectively. The results show that yield stress fluids can be used for aneurysm embolization provided the yield stress value is 20 Pa or higher. Specifically, flow recirculation in the aneurysm and the size of the inflow jet impingement zone on the aneurysm wall are substantially reduced by yield stress fluid treatment. Overall, this study opens up the possibility of using yield stress fluids for effective embolization of large-volume intracranial aneurysms.

  10. Two-fluid flowing equilibria of spherical torus sustained by coaxial helicity injection

    NASA Astrophysics Data System (ADS)

    Kanki, Takashi; Steinhauer, Loren; Nagata, Masayoshi

    2007-11-01

    Two-dimensional equilibria in helicity-driven systems using two-fluid model were previously computed, showing the existence of an ultra-low-q spherical torus (ST) configuration with diamagnetism and higher beta. However, this computation assumed purely toroidal ion flow and uniform density. The purpose of the present study is to apply the two-fluid model to the two-dimensional equilibria of helicity-driven ST with non-uniform density and both toroidal and poloidal flows for each species by means of the nearby-fluids procedure, and to explore their properties. We focus our attention on the equilibria relevant to the HIST device, which are characterized by either driven or decaying λ profiles. The equilibrium for the driven λ profile has a diamagnetic toroidal field, high-β (βt = 32%), and centrally broad density. By contrast, the decaying equilibrium has a paramagnetic toroidal field, low-β (βt = 10%), and centrally peaked density with a steep gradient in the outer edge region. In the driven case, the toroidal ion and electron flows are in the same direction, and two-fluid effects are less important since the ExB drift is dominant. In the decaying case, the toroidal ion and electron flows are opposite in the outer edge region, and two-fluid effects are significant locally in the edge due to the ion diamagnetic drift.

  11. Perpetual motion and driven dynamics of a mobile impurity in a quantum fluid

    NASA Astrophysics Data System (ADS)

    Lychkovskiy, O.

    2015-04-01

    We study the dynamics of a mobile impurity in a quantum fluid at zero temperature. Two related settings are considered. In the first setting, the impurity is injected in the fluid with some initial velocity v0, and we are interested in its velocity at infinite time, v∞. We derive a rigorous upper bound on | v0-v∞| for initial velocities smaller than the generalized critical velocity. In the limit of vanishing impurity-fluid coupling, this bound amounts to v∞=v0 , which can be regarded as a rigorous proof of the Landau criterion of superfluidity. In the case of a finite coupling, the velocity of the impurity can drop, but not to zero; the bound quantifies the maximal possible drop. In the second setting, a small constant force is exerted upon the impurity. We argue that two distinct dynamical regimes exist—backscattering oscillations of the impurity velocity and saturation of the velocity without oscillations. For fluids with vc L=vs (where vc L and vs are the Landau critical velocity and sound velocity, respectively), the latter regime is realized. For fluids with vc L

  12. Calculation of a solid/liquid surface tension: A methodological study

    NASA Astrophysics Data System (ADS)

    Dreher, T.; Lemarchand, C.; Soulard, L.; Bourasseau, E.; Malfreyt, P.; Pineau, N.

    2018-01-01

    The surface tension of a model solid/liquid interface constituted of a graphene sheet surrounded by liquid methane has been computed using molecular dynamics in the Kirkwood-Buff formalism. We show that contrary to the fluid/fluid case, the solid/liquid case can lead to different structurations of the first fluid layer, leading to significantly different values of surface tension. Therefore we present a statistical approach that consists in running a series of molecular simulations of similar systems with different initial conditions, leading to a distribution of surface tensions from which an average value and uncertainty can be extracted. Our results suggest that these distributions converge as the system size increases. Besides we show that surface tension is not particularly sensitive to the choice of the potential energy cutoff and that long-range corrections can be neglected contrary to what we observed in the liquid/vapour interfaces. We have not observed the previously reported commensurability effect.

  13. Gallium-67 scintigraphy, bronchoalveolar lavage, and pathologic changes in patients with pulmonary sarcoidosis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Abe, S.; Munakata, M.; Nishimura, M.

    1984-05-01

    The intensity of gallium-67 scintiscans, lymphocyte counts in bronchoalveolar lavage fluid, and pathologic changes were studied in 26 patients with untreated pulmonary sarcoidosis. Noncaseating granulomas were recognized with significantly greater frequency in stage 2 (80 percent; 8/10 cases) than in stage 1 (43 percent; 6/14 cases). Alveolitis showed little relation to the roentgenographic stage. There was a strong correlation between the intensity of gallium uptake in pulmonary parenchyma and the detection rate of granuloma; however, the detection rate of alveolitis was not statistically different from the intensity of gallium uptake. A highly significant correlation was revealed between the lymphocyte countsmore » in bronchoalveolar lavage fluid and the intensity of alveolitis. These observations suggest that the gallium uptake reflects mainly the presence of granuloma, and the lymphocyte count in bronchoalveolar lavage fluid reflects the intensity of alveolitis in patients with pulmonary sarcoidosis.« less

  14. Sulfide scaling in low enthalpy geothermal environments; A survey

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Criaud, A.; Fouillac, C.

    1989-01-01

    A review of the sulfide scaling phenomena in low-temperature environments is presented. While high-temperature fluids tend to deposit metal sulfides because of their high concentrations of dissolved metals and variations of temperature, pressure and fluid chemistry, low temperature media are characterized by very low metal content but much higher dissolved sulfide. In the case of the goethermal wells of the Paris Basin, detailed studies demonstrate that the relatively large concentrations of chloride and dissolved sulfide are responsible for corrosion and consequent formation of iron sulfide scale composed of mackinawite, pyrite and pyrrhotite. The effects of the exploitation schemes are farmore » less important than the corrosion of the casings. The low-enthalpy fluids that do not originate from sedimentary aquifers (such as in Iceland and Bulgaria), have a limited corrosion potential, and the thin sulfide film that appears may prevent the progress of corrosion.« less

  15. [Occupational exposure risk to body fluids in the Felix Bulnes Hospital during eleven years].

    PubMed

    Villarroel, Julia; Bustamante, M Cecilia; Manríquez, Iván; Bertoglia, M Paz; Mora, María; Galarce, Natalie

    2012-06-01

    Accidents with risk of occupational exposure to body fluids constitute more of a third of labor accidents. To describe the annual incidence of accidents with exposure to body fluids in the Felix Bulnes Hospital from 1998 to 2008. A retrospective analysis of reports from the Infection Control Committee. During 11 years, there were 415 accidents with exposure to body fluids, with the cumulative incidence of 3,4% (range 1.3% to 6%). Sharp instrument accidents accounted for 92,5% of cases. The main health care providers affected were the paramedical technicians and the students. The highest frequency of accidents occurred in the obstetrical operating rooms (20%) and in the central operating rooms (17%). There were no cases of seroconversion and no exposure to HCV or HBV. The estimated costs were USD $35638,6 or USD $271 per 1000 staff per year. The incidence increased during the first years of the study and then remained stable since 2001, despite efforts in training personnel. Many factors contribute to the development of these accidents, such as lack of experience, type of clinical benefit and even daytime working hours.

  16. Effects of irregular cerebrospinal fluid production rate in human brain ventricular system

    NASA Astrophysics Data System (ADS)

    Hadzri, Edi Azali; Shamsudin, Amir Hamzah; Osman, Kahar; Abdul Kadir, Mohammed Rafiq; Aziz, Azian Abd

    2012-06-01

    Hydrocephalus is an abnormal accumulation of fluid in the ventricles and cavities in the brain. It occurs when the cerebrospinal fluid (CSF) flow or absorption is blocked or when excessive CSF is secreted. The excessive accumulation of CSF results in an abnormal widening of the ventricles. This widening creates potentially harmful pressure on the tissues of the brain. In this study, flow analysis of CSF was conducted on a three-dimensional model of the third ventricle and aqueduct of Sylvius, derived from MRI scans. CSF was modeled as Newtonian Fluid and its flow through the region of interest (ROI) was done using EFD. Lab software. Different steady flow rates through the Foramen of Monro, classified by normal and hydrocephalus cases, were modeled to investigate its effects. The results show that, for normal and hydrocephalus cases, the pressure drop of CSF flow across the third ventricle was observed to be linearly proportionally to the production rate increment. In conclusion, flow rates that cause pressure drop of 5 Pa was found to be the threshold for the initial sign of hydrocephalus.

  17. Fully-coupled aeroelastic simulation with fluid compressibility — For application to vocal fold vibration

    PubMed Central

    Yang, Jubiao; Wang, Xingshi; Krane, Michael; Zhang, Lucy T.

    2017-01-01

    In this study, a fully-coupled fluid–structure interaction model is developed for studying dynamic interactions between compressible fluid and aeroelastic structures. The technique is built based on the modified Immersed Finite Element Method (mIFEM), a robust numerical technique to simulate fluid–structure interactions that has capabilities to simulate high Reynolds number flows and handles large density disparities between the fluid and the solid. For accurate assessment of this intricate dynamic process between compressible fluid, such as air and aeroelastic structures, we included in the model the fluid compressibility in an isentropic process and a solid contact model. The accuracy of the compressible fluid solver is verified by examining acoustic wave propagations in a closed and an open duct, respectively. The fully-coupled fluid–structure interaction model is then used to simulate and analyze vocal folds vibrations using compressible air interacting with vocal folds that are represented as layered viscoelastic structures. Using physiological geometric and parametric setup, we are able to obtain a self-sustained vocal fold vibration with a constant inflow pressure. Parametric studies are also performed to study the effects of lung pressure and vocal fold tissue stiffness in vocal folds vibrations. All the case studies produce expected airflow behavior and a sustained vibration, which provide verification and confidence in our future studies of realistic acoustical studies of the phonation process. PMID:29527067

  18. Instability of displacement of Oldroyd-B fluid by air in a Hele-Shaw cell

    NASA Astrophysics Data System (ADS)

    Daripa, Prabir

    2014-03-01

    We study the displacement of an Oldroyd-B fluid in a Hele-Shaw cell when driven by air. In particular, we explicitly obtain an analytical expression for the growth rate of instability which depends on the relaxation and retardation (time) constants, denoted by λ, and λ1 respectively, appearing in the Oldroyd-B constitutive relations. When these two constants are zero, we recover the classical Saffman-Taylor result for a Newtonian liquid displaced by air. Our results show that this displacement process is more unstable than the case when a Newtonian fluid is displaced by air. The analytical results are plotted and compared with numerical results on this unstable displacement process available in the literature. The agreement is found to be excellent. In particular, results show that the non-Newtonian case (i.e., Oldroyd-B) is more unstable than the Newtonian case. Supported by an NPRP Grant # 08-777-1-141 from the Qatar National Research Fund (a member of the Qatar Foundation). The statements made herein are solely the responsibility of the author.

  19. Three dimensional fluid-kinetic model of a magnetically guided plasma jet

    NASA Astrophysics Data System (ADS)

    Ramos, Jesús J.; Merino, Mario; Ahedo, Eduardo

    2018-06-01

    A fluid-kinetic model of the collisionless plasma flow in a convergent-divergent magnetic nozzle is presented. The model combines the leading-order Vlasov equation and the fluid continuity and perpendicular momentum equation for magnetized electrons, and the fluid equations for cold ions, which must be solved iteratively to determine the self-consistent plasma response in a three-dimensional magnetic field. The kinetic electron solution identifies three electron populations and provides the plasma density and pressure tensor. The far downstream asymptotic behavior shows the anisotropic cooling of the electron populations. The fluid equations determine the electric potential and the fluid velocities. In the small ion-sound gyroradius case, the solution is constructed one magnetic line at a time. In the large ion-sound gyroradius case, ion detachment from magnetic lines makes the problem fully three-dimensional.

  20. Numerical Study of Cattaneo-Christov Heat Flux Model for Viscoelastic Flow Due to an Exponentially Stretching Surface.

    PubMed

    Ahmad Khan, Junaid; Mustafa, M; Hayat, T; Alsaedi, A

    2015-01-01

    This work deals with the flow and heat transfer in upper-convected Maxwell fluid above an exponentially stretching surface. Cattaneo-Christov heat flux model is employed for the formulation of the energy equation. This model can predict the effects of thermal relaxation time on the boundary layer. Similarity approach is utilized to normalize the governing boundary layer equations. Local similarity solutions are achieved by shooting approach together with fourth-fifth-order Runge-Kutta integration technique and Newton's method. Our computations reveal that fluid temperature has inverse relationship with the thermal relaxation time. Further the fluid velocity is a decreasing function of the fluid relaxation time. A comparison of Fourier's law and the Cattaneo-Christov's law is also presented. Present attempt even in the case of Newtonian fluid is not yet available in the literature.

  1. Designing with non-linear viscoelastic fluids

    NASA Astrophysics Data System (ADS)

    Schuh, Jonathon; Lee, Yong Hoon; Allison, James; Ewoldt, Randy

    2017-11-01

    Material design is typically limited to hard materials or simple fluids; however, design with more complex materials can provide ways to enhance performance. Using the Criminale-Ericksen-Filbey (CEF) constitutive model in the thin film lubrication limit, we derive a modified Reynolds Equation (based on asymptotic analysis) that includes shear thinning, first normal stress, and terminal regime viscoelastic effects. This allows for designing non-linear viscoelastic fluids in thin-film creeping flow scenarios, i.e. optimizing the shape of rheological material properties to achieve different design objectives. We solve the modified Reynolds equation using the pseudo-spectral method, and describe a case study in full-film lubricated sliding where optimal fluid properties are identified. These material-agnostic property targets can then guide formulation of complex fluids which may use polymeric, colloidal, or other creative approaches to achieve the desired non-Newtonian properties.

  2. Stability of stationary solutions for inflow problem on the micropolar fluid model

    NASA Astrophysics Data System (ADS)

    Yin, Haiyan

    2017-04-01

    In this paper, we study the asymptotic behavior of solutions to the initial boundary value problem for the micropolar fluid model in a half-line R+:=(0,∞). We prove that the corresponding stationary solutions of the small amplitude to the inflow problem for the micropolar fluid model are time asymptotically stable under small H1 perturbations in both the subsonic and degenerate cases. The microrotation velocity brings us some additional troubles compared with Navier-Stokes equations in the absence of the microrotation velocity. The proof of asymptotic stability is based on the basic energy method.

  3. Role of Fluids in Lunar vs. Terrestrial Gabbros During Late-Stage and Post-Magmatic Crystallization, a Case Study

    NASA Astrophysics Data System (ADS)

    Fagan, T. J.; Fujimoto, A.; Kosaka, D.

    2018-04-01

    Incompatible elements, including H2O, are concentrated in late-stage magmatic pockets in gabbros from the Earth and Moon. Feldspar near the pockets is albitized by water (Earth case) or has discontinuous, unexplained changes in composition (Moon).

  4. Device for temporarily closing duct-formers in well completion apparatus

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zandmer, H.M.; Zandmer, S.M.

    A duct-forming device is disclosed for use in a well completion apparatus of the kind, wherein a bore hole casing is positioned in a bore hole and duct-forming devices of alkali- and acid resistant metal-such as steel-are secured at spaced levels to the casing in alignment with holes machined in the casing wall. In accordance with the invention, a closure device is arranged within the duct-forming device which permits flow of predetermined amounts of liquid, such as acid, from the interior of the casing through the duct-forming device and into the producing formation, while gradually being moved by the liquidmore » into a position in which such fluid flow is prevented. After the fluid flow has been stopped by the closure device and when the formation pressure exceeds the pressure within the duct-forming device and the casing, fluid from the formation then forces the closure device toward and into the casing space to permit thereafter free flow of formation fluid into the duct-forming device and the casing or of pressurized treatment liquid from the casing into the formation. The inventive arrangement permits inter alia the establishment of a sufficient and substantially uniform feeding rate of treatment liquid, such as acid, from the casing into the producing formation through all the duct-formers in preparation for subsequent acidification or other treatments, such as sand fracking.« less

  5. Study of the long-time dynamics of a viscous vortex sheet with a fully adaptive nonstiff method

    NASA Astrophysics Data System (ADS)

    Ceniceros, Hector D.; Roma, Alexandre M.

    2004-12-01

    A numerical investigation of the long-time dynamics of two immiscible two-dimensional fluids shearing past one another is presented. The fluids are incompressible and the interface between the bulk phases is subjected to surface tension. The simple case of density and viscosity matched fluids is considered. The two-dimensional Navier-Stokes equations are solved numerically with a fully adaptive nonstiff strategy based on the immersed boundary method. Dynamically adaptive mesh refinements are used to cover at all times the separately tracked fluid interface at the finest grid level. In addition, by combining adaptive front tracking, in the form of continuous interface marker equidistribution, with a predictor-corrector discretization an efficient method is introduced to successfully treat the well-known numerical difficulties associated with surface tension. The resulting numerical method can be used to compute stably and with high resolution the flow for wide-ranging Weber numbers but this study focuses on the computationally challenging cases for which elongated fingering and interface roll-up are observed. To assess the importance of the viscous and vortical effects in the interfacial dynamics the full viscous flow simulations are compared with inviscid counterparts computed with a state-of-the-art boundary integral method. In the examined cases of roll-up, it is found that in contrast to the inviscid flow in which the interface undergoes a topological reconfiguration, the viscous interface remarkably escapes self-intersection and rich long-time dynamics due to separation, transport, and diffusion of vorticity is observed. An even more striking motion occurs at an intermediate Weber number for which elongated interpenetrating fingers of fluid develop. In this case, it is found that the Kelvin-Helmholtz instability weakens due to shedding of vorticity and unlike the inviscid counterpart in which there is indefinite finger growth the viscous interface is pulled back by surface tension. As the interface recedes, thin necks connecting pockets of fluid with the rest of the fingers form. Narrow jets are observed at the necking regions but the vorticity there ultimately appears to be insufficient to drain all the fluid and cause reconnection. However, at another point, two disparate portions of the interface come in close proximity as the interface continues to contract. Large curvature points and an intense concentration of vorticity are observed in this region and then the motion is abruptly terminated by the collapse of the interface.

  6. Drag Optimization Of Light Trucks Using Computational Fluid Dynamics

    DTIC Science & Technology

    2003-09-01

    dimensional design case 19 study on the Lockheed C-141B aircraft wing, Cosentino and Holst [Ref. 10] reduced the number of design variables from 120 to 12... case letters) 6. AUTHOR(S) 5. FUNDING NUMBERS 7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES) Naval Postgraduate School Monterey, CA 93943...23 B. TWO DIMENSIONAL LIGHT TRUCK SHAPE STUDIES .................. 23 1. Canopies

  7. Sterile Seroma Resulting from Multilevel XLIF Procedure as Possible Adverse Effect of Prophylactic Vancomycin Powder: A Case Report

    PubMed Central

    Youssef, Jim A.; Orndorff, Douglas G.; Scott, Morgan A.; Ebner, Rachel E.; Knewitz, Allison P.

    2014-01-01

    Study Design Case report. Objective The objective of this study was to present the unusual case of a 59-year-old woman with a reoccurring sterile postoperative seroma. Methods A patient was observed postoperatively for any complications or adverse side effects resulting from an initial multilevel anterior/posterior lumbar fusion surgery where 2 g (1 g combined with the bone graft used for posterolateral fusion and 1 g placed in the soft tissues) of prophylactic vancomycin powder was placed within the soft tissues posteriorly before wound closure. The patient's progress was monitored through 6 months following the initial procedure. Six weeks postoperatively, the patient sustained a fall and had increased pain. Magnetic resonance imaging, computed tomography, and X-rays demonstrated a displaced sacral fracture, a large epidural fluid collection, and severe compression of the thecal sac at the lumbar operative sites (L3–5). Results On the basis of the aforementioned imaging studies and the patient's progressive neurologic deficit, it was apparent at the 6-week follow-up that emergent surgical intervention was necessary. Drainage and examination of an epidural fluid collection along with treatment of a displaced sacral fracture (S1–S2) were performed. The patient had an uneventful postoperative course with resolution of her back pain and neurologic deficit; however, recurrence of the epidural fluid collection requiring serial aspirations confounded the patients' clinical presentation. Conclusions With the recurrent nature of the seroma being unusual, the cause of the fluid collection and formation is undetermined. With lack of bone morphogenetic protein usage, and few confounding variables accountable, an acute allergic response to topical vancomycin powder is a possible etiology. Analysis with larger patient populations comparing postoperative adverse effects of prophylactic vancomycin powder is recommended. PMID:25364326

  8. Sterile Seroma Resulting from Multilevel XLIF Procedure as Possible Adverse Effect of Prophylactic Vancomycin Powder: A Case Report.

    PubMed

    Youssef, Jim A; Orndorff, Douglas G; Scott, Morgan A; Ebner, Rachel E; Knewitz, Allison P

    2014-10-01

    Study Design Case report. Objective The objective of this study was to present the unusual case of a 59-year-old woman with a reoccurring sterile postoperative seroma. Methods A patient was observed postoperatively for any complications or adverse side effects resulting from an initial multilevel anterior/posterior lumbar fusion surgery where 2 g (1 g combined with the bone graft used for posterolateral fusion and 1 g placed in the soft tissues) of prophylactic vancomycin powder was placed within the soft tissues posteriorly before wound closure. The patient's progress was monitored through 6 months following the initial procedure. Six weeks postoperatively, the patient sustained a fall and had increased pain. Magnetic resonance imaging, computed tomography, and X-rays demonstrated a displaced sacral fracture, a large epidural fluid collection, and severe compression of the thecal sac at the lumbar operative sites (L3-5). Results On the basis of the aforementioned imaging studies and the patient's progressive neurologic deficit, it was apparent at the 6-week follow-up that emergent surgical intervention was necessary. Drainage and examination of an epidural fluid collection along with treatment of a displaced sacral fracture (S1-S2) were performed. The patient had an uneventful postoperative course with resolution of her back pain and neurologic deficit; however, recurrence of the epidural fluid collection requiring serial aspirations confounded the patients' clinical presentation. Conclusions With the recurrent nature of the seroma being unusual, the cause of the fluid collection and formation is undetermined. With lack of bone morphogenetic protein usage, and few confounding variables accountable, an acute allergic response to topical vancomycin powder is a possible etiology. Analysis with larger patient populations comparing postoperative adverse effects of prophylactic vancomycin powder is recommended.

  9. Use of computational fluid dynamics in respiratory medicine.

    PubMed

    Fernández Tena, Ana; Casan Clarà, Pere

    2015-06-01

    Computational Fluid Dynamics (CFD) is a computer-based tool for simulating fluid movement. The main advantages of CFD over other fluid mechanics studies include: substantial savings in time and cost, the analysis of systems or conditions that are very difficult to simulate experimentally (as is the case of the airways), and a practically unlimited level of detail. We used the Ansys-Fluent CFD program to develop a conducting airway model to simulate different inspiratory flow rates and the deposition of inhaled particles of varying diameters, obtaining results consistent with those reported in the literature using other procedures. We hope this approach will enable clinicians to further individualize the treatment of different respiratory diseases. Copyright © 2014 SEPAR. Published by Elsevier Espana. All rights reserved.

  10. Vibration isolation technology: Sensitivity of selected classes of experiments to residual accelerations

    NASA Technical Reports Server (NTRS)

    Alexander, J. Iwan D.

    1990-01-01

    The solution was sought of a 2-D axisymmetric moving boundary problem for the sensitivity of isothermal and nonisothermal liquid columns and the sensitivity of thermo-capillary flows to buoyancy driven convection caused by residual accelerations. The sensitivity of a variety of space experiments to residual accelerations are examined. In all the cases discussed, the sensitivity is related to the dynamic response of a fluid. In some cases the sensitivity can be defined by the magnitude of the response of the velocity field. This response may involve motion of the fluid associated with internal density gradients, or the motion of a free liquid surface. For fluids with internal density gradients, the type of acceleration to which the experiment is sensitive will depend on whether buoyancy driven convection must be small in comparison to other types of fluid motion (such as thermocapillary flow), or fluid motion must be suppressed or eliminated (such as in diffusion studies, or directional solidification experiments). The effect of the velocity on the composition and temperature field must be considered, particularly in the vicinity of the melt crystal interface. As far as the response to transient disturbances is concerned the sensitivity is determined by both the magnitude and frequency the acceleration and the characteristic momentum and solute diffusion times.

  11. Viscous effects on the Rayleigh-Taylor instability with background temperature gradient

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gerashchenko, Sergiy; Livescu, Daniel

    Here we studied the growth rate of the compressible Rayleigh-Taylor instability in the presence of a background temperature gradient, Θ, using a normal mode analysis. The effect of Θ variation is examined for three interface types corresponding to the combinations of the viscous properties of the fluids (inviscid-inviscid, viscous-viscous, and viscous-inviscid) at different Atwood numbers, At, and when at least one of the fluids' viscosity is non-zero, as a function of the Grashof number. For the general case, the resulting ordinary differential equations are solved numerically; however, dispersion relations for the growth rate are presented for several limiting cases. Anmore » analytical solution is found for the inviscid-inviscid interface and the corresponding dispersion equation for the growth rate is obtained in the limit of large Θ. For the viscous-inviscid case, a dispersion relation is derived in the incompressible limit and Θ=0. Compared to Θ=0 case, the role of Θ<0 (hotter light fluid) is destabilizing and becomes stabilizing when Θ>0 (colder light fluid). The most pronounced effect of Θ ≠ 0 is found at low At and/or at large perturbation wavelengths relative to the domain size for all interface types. On the other hand, at small perturbation wavelengths relative to the domain size, the growth rate for the Θ<0 case exceeds the infinite domain incompressible constant density result. The results are applied to two practical examples, using sets of parameters relevant to Inertial Confinement Fusion coasting stage and solar corona plumes. The role of viscosity on the growth rate reduction is discussed together with highlighting the range of wavenumbers most affected by viscosity. The viscous effects further increase in the presence of background temperature gradient, when the viscosity is temperature dependent.« less

  12. Viscous effects on the Rayleigh-Taylor instability with background temperature gradient

    DOE PAGES

    Gerashchenko, Sergiy; Livescu, Daniel

    2016-07-28

    Here we studied the growth rate of the compressible Rayleigh-Taylor instability in the presence of a background temperature gradient, Θ, using a normal mode analysis. The effect of Θ variation is examined for three interface types corresponding to the combinations of the viscous properties of the fluids (inviscid-inviscid, viscous-viscous, and viscous-inviscid) at different Atwood numbers, At, and when at least one of the fluids' viscosity is non-zero, as a function of the Grashof number. For the general case, the resulting ordinary differential equations are solved numerically; however, dispersion relations for the growth rate are presented for several limiting cases. Anmore » analytical solution is found for the inviscid-inviscid interface and the corresponding dispersion equation for the growth rate is obtained in the limit of large Θ. For the viscous-inviscid case, a dispersion relation is derived in the incompressible limit and Θ=0. Compared to Θ=0 case, the role of Θ<0 (hotter light fluid) is destabilizing and becomes stabilizing when Θ>0 (colder light fluid). The most pronounced effect of Θ ≠ 0 is found at low At and/or at large perturbation wavelengths relative to the domain size for all interface types. On the other hand, at small perturbation wavelengths relative to the domain size, the growth rate for the Θ<0 case exceeds the infinite domain incompressible constant density result. The results are applied to two practical examples, using sets of parameters relevant to Inertial Confinement Fusion coasting stage and solar corona plumes. The role of viscosity on the growth rate reduction is discussed together with highlighting the range of wavenumbers most affected by viscosity. The viscous effects further increase in the presence of background temperature gradient, when the viscosity is temperature dependent.« less

  13. Contribution of neonatal amniotic fluid testing to diagnosis of congenital toxoplasmosis.

    PubMed

    Filisetti, Denis; Yera, Hélène; Villard, Odile; Escande, Benoît; Wafo, Estelle; Houfflin-Debarge, Véronique; Delhaes, Laurence; Bastien, Patrick

    2015-05-01

    We evaluated the molecular diagnosis of congenital toxoplasmosis (CT) on neonatal amniotic fluid samples from 488 mother-child pairs. Maternal infection during pregnancy was diagnosed and dated or could not be ruled out. Forty-six cases of CT were defined according to the European Research Network on CT classification system and case definitions. Neonatal amniotic fluid testing had an overall sensitivity of 54% (95% confidence interval [95% CI], 39 to 69%) and a specificity of 100% (95% CI, 99 to 100%). Its sensitivity was 33% (95% CI, 13 to 59%) when antenatal diagnosis was positive and 68% (95% CI, 48 to 84%) when antenatal diagnosis was negative or lacking. This difference in sensitivity may have been due to treatment of antenatally diagnosed cases. Relative to postnatal serology, neonatal amniotic fluid testing allowed an earlier diagnosis to be made in 26% of the cases (95% CI, 9 to 51%). Copyright © 2015, American Society for Microbiology. All Rights Reserved.

  14. Comparing the Richtmyer-Meshkov instability of thermal and ion-species interfaces in two-fluid plasmas

    NASA Astrophysics Data System (ADS)

    Wheatley, Vincent; Bond, Daryl; Li, Yuan; Samtaney, Ravi; Pullin, Dale

    2017-11-01

    The Richtmyer-Meshkov instability (RMI) of a shock accelerated perturbed density interface is important in both inertial confinement fusion and astrophysics, where the materials involved are typically in the plasma state. Initial density interfaces can be due to either temperature or ion-species discontinuities. If the Atwood number of the interfaces and specific heat ratios of the fluids are matched, these two cases behave similarly when modeled using the equations of either hydrodynamics or magnetohydrodynamics. In the two-fluid ion-electron plasma model, however, there is a significant difference between them: In the thermal interface case, there is a discontinuity in electron density that is also subject to the RMI, while for the ion-species interface case there is not. It will be shown via ideal two-fluid plasma simulations that this causes substantial differences in the dynamics of the flow between the two cases. This work was partially supported by the KAUST Office of Sponsored Research under Award URF/1/2162-01.

  15. Electro-elastoviscous response of polyaniline functionalized nano-porous zeolite based colloidal dispersions.

    PubMed

    Chattopadhyay, Ankur; Rani, Poonam; Srivastava, Rajendra; Dhar, Purbarun

    2018-06-01

    The present article discusses the typical influence of grafted conducting polymers in the mesoscale pores of dielectric particles on the static and dynamic electrorheology and electro-viscoelastic behavior of corresponding colloids. Nanocrystalline meso-nanoporous zeolite has been prepared by chemical synthesis and subsequently polyaniline (PANI) coating has been implemented. Electrorheological (ER) suspensions have been formed by dispersing the nanoparticles in silicone oil and their viscoelastic behaviors are examined to understand the nature of such complex colloidal systems under electric fields. PANI-Zeolite ER fluids demonstrate higher static electroviscous effects and yield stress potential than untreated Zeolite, typically studied in literature. Transient electro-viscous characterizations show a stable and negligible hysteresis behavior when both the fluids are exposed to constant as well as time varying electric field intensities. Further oscillatory shear experiments of frequency and strain sweeps exhibit predominant elastic behavior in case of Zeolite based ER suspensions as compared to PANI systems. Detailed investigations reveal Zeolite based ER suspensions display enhanced relative yielding as well as electro-viscoelastic stability than the PANI-Zeolite. The steady state viscous behaviors are scaled against the non-dimensional Mason number to model the system behavior for both fluids. Experimental data of flow behaviors of both the ER fluids are compared with semi-classical models and it is found that the CCJ model possesses a closer proximity than traditional Bingham model, thereby revealing the fluids to be generic pseudo-linear fluids. The present article reveals that while the PANI based fluids are typically hailed superior in literature, it is only restricted to steady shear utilities. In case of dynamic and oscillatory systems, the traditional Zeolite based fluids exhibit superior ER caliber. Copyright © 2018 Elsevier Inc. All rights reserved.

  16. Non-Darcian flow of shear-thinning fluids through packed beads: Experiments and predictions using Forchheimer's law and Ergun's equation

    NASA Astrophysics Data System (ADS)

    Rodríguez de Castro, Antonio; Radilla, Giovanni

    2017-02-01

    The flow of shear-thinning fluids through unconsolidated porous media is present in a number of important industrial applications such as soil depollution, Enhanced Oil Recovery or filtration of polymeric liquids. Therefore, predicting the pressure drop-flow rate relationship in model porous media has been the scope of major research efforts during the last decades. Although the flow of Newtonian fluids through packs of spherical particles is well understood in most cases, much less is known regarding the flow of shear-thinning fluids as high molecular weight polymer aqueous solutions. In particular, the experimental data for the non-Darcian flow of shear-thinning fluids are scarce and so are the current approaches for their prediction. Given the relevance of non-Darcian shear-thinning flow, the scope of this work is to perform an experimental study to systematically evaluate the effects of fluid shear rheology on the flow rate-pressure drop relationships for the non-Darcian flow through different packs of glass spheres. To do so, xanthan gum aqueous solutions with different polymer concentrations are injected through four packs of glass spheres with uniform size under Darcian and inertial flow regimes. A total of 1560 experimental data are then compared with predictions coming from different methods based on the extension of widely used Ergun's equation and Forchheimer's law to the case of shear thinning fluids, determining the accuracy of these predictions. The use of a proper definition for Reynolds number and a realistic model to represent the rheology of the injected fluids results in the porous media are shown to be key aspects to successfully predict pressure drop-flow rate relationships for the inertial shear-thinning flow in packed beads.

  17. Intra-abdominal fluid extravasation during hip arthroscopy: a survey of the MAHORN group.

    PubMed

    Kocher, Mininder S; Frank, Jeremy S; Nasreddine, Adam Y; Safran, Marc R; Philippon, Marc J; Sekiya, Jon K; Kelly, Bryan T; Byrd, J W Thomas; Guanche, Carlos A; Martin, Hal D; Clohisy, John C; Mohtadi, Nick G; Griffin, Damian R; Sampson, Thomas G; Leunig, Michael; Larson, Christopher M; Ilizaliturri, Victor M; McCarthy, Joseph C; Gambacorta, Peter G

    2012-11-01

    The purpose of this study was to survey experts in the field of hip arthroscopy from the Multicenter Arthroscopy of the Hip Outcomes Research Network (MAHORN) group to determine the frequency of symptomatic intra-abdominal fluid extravasation (IAFE) after arthroscopic hip procedures, identify potential risk factors, and develop preventative measures and treatment strategies in the event of symptomatic IAFE. A survey was sent to all members of the MAHORN group. Surveys collected data on general hip arthroscopy settings, including pump pressure and frequency of different hip arthroscopies performed, as well as details on cases of symptomatic IAFE. Responses to the survey were documented and analyzed. Fifteen hip arthroscopists from the MAHORN group were surveyed. A total of 25,648 hip arthroscopies between 1984 and 2010 were reviewed. Arthroscopic procedures included capsulotomies, labral reattachment after acetabuloplasty, peripheral compartment arthroscopy, and osteoplasty of the femoral head-neck junction. Of the arthroscopists, 7 (47%) had 1 or more cases of IAFE (40 cases reported). The prevalence of IAFE in this study was 0.16% (40 of 25,650). Significant risk factors associated with IAFE were higher arthroscopic fluid pump pressure (P = .004) and concomitant iliopsoas tenotomy (P < .001). In all 40 cases, the condition was successfully treated without long-term sequelae. Treatment options included observation, intravenous furosemide, and Foley catheter placement, as well as 1 case of laparotomy. Symptomatic IAFE after hip arthroscopy is a rare occurrence, with an approximate prevalence of 0.16%. Prevention of IAFE should include close intraoperative and postoperative monitoring of abdominal distention, core body temperature, and hemodynamic stability. Concomitant iliopsoas tenotomy and high pump pressures may be risk factors leading to symptomatic IAFE. Level IV, therapeutic case series. Copyright © 2012 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  18. Sample environment for in situ synchrotron XRD measurements for CO2 interaction with subsurface materials

    NASA Astrophysics Data System (ADS)

    Elbakhshwan, M.; Gill, S.; Weidner, R.; Ecker, L.

    2017-12-01

    Sequestration of CO2 in geological formations requires a deep understanding of its interaction with the cement-casing components in the depleted oil and gas wells. Portland cement is used to seal the wellbores; however it tends to interact with the CO2. Therefore it is critical to investigate the wellbore integrity over long term exposure to CO2. Studies showed that, CO2 leakage is due to the flow through the casing-cement microannulus, cement-cement fractures, or the cement-caprock interface. The objective of this work is to gain a better understanding of the dissolution process of the cement-casing in the CO2 flow channels alongside with the carbonation reactions at the interfaces using XRF, XANES and X-ray tomography techniques. In this study, a synthetic wellbore system, consisting of cement with an embedded rectangular length of steel casing that had grooves to accommodate fluid flow, was used to investigate the casing-cement microannulus through core-flood experiments. The objective of this work is to gain a better understanding of the dissolution process of the cement-casing in the CO2 flow channels alongside with the carbonation reactions at the interfaces using a sample environment designed and built for in situ X-ray diffraction in the National Synchrotron Light Source II (NSLS II). The formation of carbonate phases at cement -fluid and cement-steel/fluid interfaces will be monitored in real time. Samples may be exposed to super critical CO2 at pressures above 1100 psi and temperatures around 50°C. The reaction cell is built from hastealloy to provide corrosion resistance, while the experimental temperature and pressure are controlled with thermocouples and pressure vessel.

  19. [Preparation of carbon fiber reinforced fluid type resin denture (author's transl)].

    PubMed

    Kasuga, H; Sato, H; Nakabayashi, N

    1980-01-01

    Transverse strength of cured fluid resins is weaker than that of the heat cured. We have studied to improve the mechanical strength of self-cured acrylic resin by application of carbon fibers as reinforcement and simple methods which must be acceptable for technicians are proposed. A cloth type carbon fiber was the best reinforcement among studied carbon fibers such as chopped or mat. The chopped fibers were difficult to mix homogeneously with fluid resins and effectiveness of the reinforcement was low. Breaking often occurred at the interface between the reinforcement and resin in the cases of mat which gave defects to the test specimens. To prepare reinforced denture, the cloth was trimmed on the master cast after removal of wax and the prepreg was formed with the alginate impression on the cast by Palapress and the cloth. Other steps were same as the usual fluid resin.

  20. Non-Newtonian fluid structure interaction in flexible biomimetic microchannels

    NASA Astrophysics Data System (ADS)

    Kiran, M.; Dasgupta, Sunando; Chakraborty, Suman

    2017-11-01

    To investigate the complex fluid structure interactions in a physiologically relevant microchannel with deformable wall and non-Newtonian fluid that flows within it, we fabricated cylindrical microchannels of various softness out of PDMS. Experiments to measure the transient pressure drop across the channel were carried out with high sampling frequencies to capture the intricate flow physics. In particular, we showed that the waveforms varies greatly for each of the non-Newtonian and Newtonian cases for both non-deformable and deformable microchannels in terms of the peak amplitude, r.m.s amplitude and the crest factor. In addition, we carried out frequency sweep experiments to evaluate the frequency response of the system. We believe that these results will aid in the design of polymer based microfluidic phantoms for arterial FSI studies, and in particular for studying blood analog fluids in cylindrical microchannels as well as developing frequency specific Lab-on-chip systems for medical diagnostics.

  1. A CFD Approach to Modeling Spacecraft Fuel Slosh

    NASA Technical Reports Server (NTRS)

    Marsell, Brandon; Gangadharan, Sathya; Chatman, Yadira; Sudermann, James; Schlee, Keith; Ristow, James E.

    2009-01-01

    Energy dissipation and resonant coupling from sloshing fuel in spacecraft fuel tanks is a problem that occurs in the design of many spacecraft. In the case of a spin stabilized spacecraft, this energy dissipation can cause a growth in the spacecrafts' nutation (wobble) that may lead to disastrous consequences for the mission. Even in non-spinning spacecraft, coupling between the spacecraft or upper stage flight control system and an unanticipated slosh resonance can result in catastrophe. By using a Computational Fluid Dynamics (CFD) solver such as Fluent, a model for this fuel slosh can be created. The accuracy of the model must be tested by comparing its results to an experimental test case. Such a model will allow for the variation of many different parameters such as fluid viscosity and gravitational field, yielding a deeper understanding of spacecraft slosh dynamics. In order to gain a better understanding of the dynamics behind sloshing fluids, the Launch Services Program (LSP) at the NASA Kennedy Space Center (KSC) is interested in finding ways to better model this behavior. Thanks to past research, a state-of-the-art fuel slosh research facility was designed and fabricated at Embry Riddle Aeronautical University (ERAU). This test facility has produced interesting results and a fairly reliable parameter estimation process to predict the necessary values that accurately characterize a mechanical pendulum analog model. The current study at ERAU uses a different approach to model the free surface sloshing of liquid in a spherical tank using Computational Fluid Dynamics (CFD) methods. Using a software package called Fluent, a model was created to simulate the sloshing motion of the propellant. This finite volume program uses a technique called the Volume of Fluid (VOF) method to model the interaction between two fluids [4]. For the case of free surface slosh, the two fluids are the propellant and air. As the fuel sloshes around in the tank, it naturally displaces the air. Using the conservation of mass, momentum, and energy equations, as well as the VOF equations, one can predict the behavior of the sloshing fluid and calculate the forces, pressure gradients, and velocity field for the entire liquid as a function of time.

  2. Falling, flapping, flying, swimming,...: High-Re fluid-solid interactions with vortex shedding

    NASA Astrophysics Data System (ADS)

    Michelin, Sebastien Honore Roland

    The coupling between the motion of a solid body and the dynamics of the surrounding flow is essential to the understanding of a large number of engineering and physical problems, from the stability of a slender structure exposed to the wind to the locomotion of insects, birds and fishes. Because of the strong coupling on a moving boundary of the equations for the solid and fluid, the simulation of such problems is computationally challenging and expensive. This justifies the development of simplified models for the fluid-solid interactions to study their physical properties and behavior. This dissertation proposes a reduced-order model for the interaction of a sharp-edged solid body with a strongly unsteady high Reynolds number flow. In such a case, viscous forces in the fluid are often negligible compared to the fluid inertia or the pressure forces, and the thin boundary layers separate from the solid at the edges, leading to the shedding of large and persistent vortices in the solid's wake. A general two-dimensional framework is presented based on complex potential flow theory. The formation of the solid's vortical wake is accounted for by the shedding of point vortices with unsteady intensity from the solid's sharp edges, and the fluid-solid problem is reformulated exclusively as a solid-vortex interaction problem. In the case of a rigid solid body, the coupled problem is shown to reduce to a set of non-linear ordinary differential equations. This model is used to study the effect of vortex shedding on the stability of falling objects. The solid-vortex model is then generalized to study the fluttering instability and non-linear flapping dynamics of flexible plates or flags. The uttering instability and resulting flapping motion result from the competing effects of the fluid forcing and of the solid's flexural rigidity and inertia. Finally, the solid-vortex model is applied to the study of the fundamental effect of bending rigidity on the flapping performance of flapping appendages such as insect wings or fish fins.

  3. Ethanol effects on binary and ternary supported lipid bilayers with gel/fluid domains and lipid rafts.

    PubMed

    Marquês, Joaquim T; Viana, Ana S; De Almeida, Rodrigo F M

    2011-01-01

    Ethanol-lipid bilayer interactions have been a recurrent theme in membrane biophysics, due to their contribution to the understanding of membrane structure and dynamics. The main purpose of this study was to assess the interplay between membrane lateral heterogeneity and ethanol effects. This was achieved by in situ atomic force microscopy, following the changes induced by sequential ethanol additions on supported lipid bilayers formed in the absence of alcohol. Binary phospholipid mixtures with a single gel phase, dipalmitoylphosphatidylcholine (DPPC)/cholesterol, gel/fluid phase coexistence DPPC/dioleoylphosphatidylcholine (DOPC), and ternary lipid mixtures containing cholesterol, mimicking lipid rafts (DOPC/DPPC/cholesterol and DOPC/sphingomyelin/cholesterol), i.e., with liquid ordered/liquid disordered (ld/lo) phase separation, were investigated. For all compositions studied, and in two different solid supports, mica and silicon, domain formation or rearrangement accompanied by lipid bilayer thinning and expansion was observed. In the case of gel/fluid coexistence, low ethanol concentrations lead to a marked thinning of the fluid but not of the gel domains. In the case of ld/lo all the bilayer thins simultaneously by a similar extent. In both cases, only the more disordered phase expanded significantly, indicating that ethanol increases the proportion of disordered domains. Water/bilayer interfacial tension variation and freezing point depression, inducing acyl chain disordering (including opening and looping), tilting, and interdigitation, are probably the main cause for the observed changes. The results presented herein demonstrate that ethanol influences the bilayer properties according to membrane lateral organization. Copyright © 2010 Elsevier B.V. All rights reserved.

  4. Hamiltonian fluid closures of the Vlasov-Ampère equations: From water-bags to N moment models

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Perin, M.; Chandre, C.; Tassi, E.

    2015-09-15

    Moment closures of the Vlasov-Ampère system, whereby higher moments are represented as functions of lower moments with the constraint that the resulting fluid system remains Hamiltonian, are investigated by using water-bag theory. The link between the water-bag formalism and fluid models that involve density, fluid velocity, pressure and higher moments is established by introducing suitable thermodynamic variables. The cases of one, two, and three water-bags are treated and their Hamiltonian structures are provided. In each case, we give the associated fluid closures and we discuss their Casimir invariants. We show how the method can be extended to an arbitrary numbermore » of fields, i.e., an arbitrary number of water-bags and associated moments. The thermodynamic interpretation of the resulting models is discussed. Finally, a general procedure to derive Hamiltonian N-field fluid models is proposed.« less

  5. An Analytical Model for Assessing Stability of Pre-Existing Faults in Caprock Caused by Fluid Injection and Extraction in a Reservoir

    NASA Astrophysics Data System (ADS)

    Wang, Lei; Bai, Bing; Li, Xiaochun; Liu, Mingze; Wu, Haiqing; Hu, Shaobin

    2016-07-01

    Induced seismicity and fault reactivation associated with fluid injection and depletion were reported in hydrocarbon, geothermal, and waste fluid injection fields worldwide. Here, we establish an analytical model to assess fault reactivation surrounding a reservoir during fluid injection and extraction that considers the stress concentrations at the fault tips and the effects of fault length. In this model, induced stress analysis in a full-space under the plane strain condition is implemented based on Eshelby's theory of inclusions in terms of a homogeneous, isotropic, and poroelastic medium. The stress intensity factor concept in linear elastic fracture mechanics is adopted as an instability criterion for pre-existing faults in surrounding rocks. To characterize the fault reactivation caused by fluid injection and extraction, we define a new index, the "fault reactivation factor" η, which can be interpreted as an index of fault stability in response to fluid pressure changes per unit within a reservoir resulting from injection or extraction. The critical fluid pressure change within a reservoir is also determined by the superposition principle using the in situ stress surrounding a fault. Our parameter sensitivity analyses show that the fault reactivation tendency is strongly sensitive to fault location, fault length, fault dip angle, and Poisson's ratio of the surrounding rock. Our case study demonstrates that the proposed model focuses on the mechanical behavior of the whole fault, unlike the conventional methodologies. The proposed method can be applied to engineering cases related to injection and depletion within a reservoir owing to its efficient computational codes implementation.

  6. Infiltration of MHD liquid into a deformable porous material

    NASA Astrophysics Data System (ADS)

    Naseem, Anum; Mahmood, Asif; Siddique, J. I.; Zhao, Lifeng

    2018-03-01

    We analyze the capillary rise dynamics for magnetohydrodynamics (MHD) fluid flow through deformable porous material in the presence of gravity effects. The modeling is performed using mixture theory approach and mathematical manipulation yields a nonlinear free boundary problem. Due to the capillary rise action, the pressure gradient in the liquid generates a stress gradient that results in the deformation of porous substrate. The capillary rise process for MHD fluid slows down as compared to Newtonian fluid case. Numerical solutions are obtained using a method of lines approach. The graphical results are presented for important physical parameters, and comparison is presented with Newtonian fluid case.

  7. 'Ease of interpretation' of cytological smears stained with modified ultrafast papanicolaou stain: Interobserver agreement and reproducibility.

    PubMed

    Uthamalingam, Preithy; Sathish Kumar, Thabasum; Venus, Albina; Sekar, Preethi; Muthusamy, Rajeshwari K; Mehta, Sangita

    2018-04-01

    Since its inception in 1995, the Ultrafast Papanicoloau (UFPAP) cytological stain has undergone a number of modifications to suit the local availability of reagents and cost in different set ups. However, the reported results have been uniformly encouraging. We designed a study to investigate the inter-observer agreement in 'perceived ease of interpretation' of cytological smears stained with Modified Ultrafast Papanicoloau stain (MUFPAP). After a small pilot study, we prospectively stained air-dried fine needle aspirate smears (FNACs) and Body Fluid smears with the standardized MUFPAP stain. The MUFPAP stained slides were evaluated in tandem with other routine cytological stains as well as independently by two pathologists. Two rater kappa was used to determine the agreement. The study included 93 fluids and 34 FNACs. A vast majority of the cases stained with MUFPAP were rated 'better' than the routine stains in terms of 'overall ease of interpretation' with considerable agreement. The agreement tended to be better for FNACs than fluid specimens. Cases with malignant pathology demonstrated a perfect agreement (kappa = 1) between the raters in terms of 'overall ease of interpretation' (91.7% cases were rated 'very good' by each pathologist) when compared to cases with benign pathology (kappa = 0.52). Nuclear characteristics were appreciated with a better agreement than other parameters. Modified UFPAP stain appears to be quick, reliable, cost-effective alternative in cytology, especially for detecting malignant cells in smears with low cellularity. Its specific advantage is robust nuclear staining against a clear background. © 2018 Wiley Periodicals, Inc.

  8. A Study of Laminar Compressible Viscous Pipe Flow Accelerated by an Axial Body Force, with Application to Magnetogasdynamics

    NASA Technical Reports Server (NTRS)

    Martin, E. Dale

    1961-01-01

    A study is made of the steady laminar flow of a compressible viscous fluid in a circular pipe when the fluid is accelerated by an axial body force. The application of the theory to the magnetofluidmechanics of an electrically conducting gas accelerated by electric and magnetic fields is discussed. Constant viscosity, thermal conductivity, and electrical conductivity are assumed. Fully developed flow velocity and temperature profiles are shown, and detailed results of the accelerating flow development, including velocity and pressure as functions of distance, are given for the case where the axial body force is constant and for the case where it is a linear function of velocity. From these results are determined the pipe entry length and the pressure difference required.

  9. Effect of ultrasound on dynamics characteristic of the cavitation bubble in grinding fluids during honing process.

    PubMed

    Guo, Ce; Zhu, Xijing

    2018-03-01

    The effect of ultrasound on generating and controlling the cavitation bubble of the grinding fluid during ultrasonic vibration honing was investigated. The grinding fluid on the surface of the honing stone was measured by utilizing the digital microscope VHX-600ESO. Based on analyzing the cavitation mechanism of the grinding fluid, the bubble dynamics model under conventional honing (CH) and ultrasonic vibration honing (UVH) was established respectively. Difference of dynamic behaviors of the bubble between the cases in UVH and CH was compared respectively, and the effects of acoustic amplitude and ultrasonic frequency on the bubble dynamics were simulated numerically using the Runge-Kutta fourth order method with variable step size adaptive control. Finally, the cavitation intensity of grinding fluids under ultrasound was measured quantitatively using acoustimeter. The results showed that the grinding fluid subjected to ultrasound can generate many bubbles and further forms numerous groups of araneose cavitation bubbles on the surface of the honing stone. The oscillation of the bubble under UVH is more intense than the case under CH, and the maximum velocity of the bubble wall under UVH is higher two magnitudes than the case under CH. For lower acoustic amplitude, the dynamic behaviors of the bubble under UVH are similar to that case under CH. As increasing acoustic amplitude, the cavitation intensity of the bubble is growing increased. Honing pressure has an inhabitation effect on cavitation effect of the grinding fluid. The perfect performance of cavitation of the grinding fluid can be obtained when the device of UVH is in the resonance. However, the cavitation intensity of the grinding fluid can be growing weakened with increasing ultrasonic frequency, when the device of UVH is in the off-resonance. The experimental results agree with the theoretical and numerical analysis, which provides a method for exploring applications of the cavitation effect in ultrasonic assisted machining. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Parosteal osteosarcoma dedifferentiating into telangiectatic osteosarcoma: importance of lytic changes and fluid cavities at imaging.

    PubMed

    Azura, M; Vanel, D; Alberghini, M; Picci, P; Staals, E; Mercuri, M

    2009-07-01

    This study was performed to assess the imaging findings in cases of parosteal osteosarcoma dedifferentiated into telangiectatic osteosarcoma. Parosteal osteosarcoma is a low-grade well-differentiated malignant tumor. Dedifferentiation into a more aggressive lesion is frequent and usually visible on imaging as a central lytic area in a sclerotic mass. Only one case of differentiation into a telangiectatic osteosarcoma has been reported. As it has practical consequences, with a need for aggressive chemotherapy, we looked for this rather typical imaging pattern. Review of 199 cases of surface osteosarcomas (including 86 parosteal, of which 23 were dedifferentiated) revealed lesions suggesting a possible telangiectatic osteosarcoma on imaging examinations in five cases (cavities with fluid). Histology confirmed three cases (the two other only had hematoma inside a dedifferentiated tumor). There were three males, aged 24, 28, and 32. They had radiographs and CT, and two an MR examination. Lesions involved the distal femur, proximal tibia, and proximal humerus. The parosteal osteosarcoma was a sclerotic, regular mass, attached to the cortex. A purely lytic mass, partially composed of fluid cavities was easily detected on CT and MR. It involved the medullary cavity twice, and remained outside the bone once. Histology confirmed the two components in each case. Two patients died of pulmonary metastases and one is alive. Knowledge of this highly suggestive pattern should help guide the initial biopsy to diagnose the two components of the tumor, and guide aggressive treatment.

  11. Modeling the Buildup of Annular Pressure in Cased and Uncased Annuli of Faulty Wellbores

    NASA Astrophysics Data System (ADS)

    Lackey, G.; Rajaram, H.

    2017-12-01

    Structurally sound wellbores are essential to oil and gas production, natural gas storage, and carbon dioxide sequestration operations. Wellbore integrity is easily assessed at the wellhead by the presence of pressure or gas flow in the outer annuli of a well, as it indicates the uncontrolled vertical migration of fluids outside the production casing. This phenomenon is typically referred to as sustained casing pressure (SCP), sustained annular pressure, or surface casing vent flow. Of particular concern is the buildup of pressure in the surface casing annulus. If the surface casing is sealed at the wellhead and cement is not brought into the bottom of the casing, annular pressure that builds induces gas migration when the fluid and entry pressure of the formation at the bottom of the surface casing is exceeded. Multiple incidents of stray gas migration from oil and gas operations have contaminated water wells in Colorado, Pennsylvania, and Ohio through this mechanism. Natural gas escaping the #25 Standard Senson well at the Aliso Gas storage facility in California, the largest accidental release of greenhouse gases in US history, also followed this pathway. Previous studies have modeled the buildup of SCP in faulty wells with fully-cased annuli that are isolated from the surrounding formation. However, the majority of onshore oil and gas wells in the US are constructed with uncased outermost annuli that are hydraulically connected to the surrounding subsurface. In this study, we adapt current approaches of modeling SCP to include the regulation of annular liquid level by formation fluid pressure, dissolution of gas into the annular liquids, the transport of aqueous gas by crossflow into deep formations, and gas migration away from the well, when the entry pressure of the formations or fractures along the uncased annulus is exceeded, to compare the buildup behavior of SCP in both uncased and fully-cased annuli. We consider well construction and subsurface geology representative of the Wattenberg Field in Colorado and interpret observations of sustained casing pressure collected by the Colorado Oil and Gas Conservation Commission. We demonstrate that the potential negative consequences of integrity loss are much greater for an uncased well than for fully-cased well.

  12. On the Singular Incompressible Limit of Inviscid Compressible Fluids

    NASA Astrophysics Data System (ADS)

    Secchi, P.

    We consider the Euler equations of barotropic inviscid compressible fluids in a bounded domain. It is well known that, as the Mach number goes to zero, the compressible flows approximate the solution of the equations of motion of inviscid, incompressible fluids. In this paper we discuss, for the boundary case, the different kinds of convergence under various assumptions on the data, in particular the weak convergence in the case of uniformly bounded initial data and the strong convergence in the norm of the data space.

  13. Responses to the lowering of magnesium and calcium concentrations in the cerebrospinal fluid of unanesthetized sheep.

    PubMed

    Allsop, T F; Pauli, J V

    1975-12-01

    A technique for ventriculolumbar perfusion of the cerebrospinal fluid space has been used to study the neuromuscular effects of low concentrations of magnesium and calcium in the cerebrospinal fluid of conscious sheep. Perfusion with synthetic cerebrospinal fluid solutions containing less than 0-6 mg magnesium/100 ml produced episodes of tetany which were abolished by perfusion with a solution of normal magnesium concentration. This suggests that the low cerebrospinal fluid magnesium concentrations reported in cases of hypomagneseamic tetany may result in changes within the central nervous system that could produce the nervous signs. Perfusates with a calcium concentration below 2-0 mg/100 ml caused hyperpnoea and continuous muscle tremors. Magnesium (0-6 mg/100 ml) and calcium (2-0 mg/100 ml) perfused simultaneously acted synergistically to produce signs characteristic of low levels of each of the ions.

  14. Pericardial fluid is suitable as an alternative specimen for the measurement of β-hydroxybutyrate within 96 h after death.

    PubMed

    Mizutani, Tatsushi; Yoshimoto, Takashi; Ishii, Akira

    2018-05-21

    We examined postmortem β-hydroxybutyrate (BHB) levels in the body fluids obtained from 253 forensic autopsy cases whose causes of death were determined. Postmortem changes of BHB levels according to postmortem intervals (PMI) in various body fluids (plasma, urine, vitreous humor, and pericardial fluids) were investigated to determine appropriate alternative specimens as plasma samples. Our study has indicated the following points: 1) the BHB levels in plasma specimens from three sampling sites showed no significant differences, 2) postmortem changes of BHB levels in plasma and pericardial fluids could be negligible within 96 h PMI, while urine and vitreous humor BHB levels showed postmortem changes, and 3) pericardial fluid would thus be most suitable as an alternative to plasma in postmortem BHB level. We have also proposed that BHB levels could be applicable for the diagnosis of metabolic disorders in forensic autopsy. Copyright © 2018 Elsevier B.V. All rights reserved.

  15. Investigation of effect of particle size and rumen fluid addition on specific methane yields of high lignocellulose grass silage.

    PubMed

    Wall, D M; Straccialini, B; Allen, E; Nolan, P; Herrmann, C; O'Kiely, P; Murphy, J D

    2015-09-01

    This work examines the digestion of advanced growth stage grass silage. Two variables were investigated: particle size (greater than 3 cm and less than 1cm) and rumen fluid addition. Batch studies indicated particle size and rumen fluid addition had little effect on specific methane yields (SMYs). In continuous digestion of 3 cm silage the SMY was 342 and 343 L CH4 kg(-1)VS, respectively, with and without rumen fluid addition. However, digester operation was significantly affected through silage floating on the liquor surface and its entanglement in the mixing system. Digestion of 1cm silage with no rumen fluid addition struggled; volatile fatty acid concentrations rose and SMYs dropped. The best case was 1cm silage with rumen fluid addition, offering higher SMYs of 371 L CH4 kg(-1)VS and stable operation throughout. Thus, physical and biological treatments benefited continuous digestion of high fibre grass silage. Copyright © 2015 Elsevier Ltd. All rights reserved.

  16. Fluid check valve has fail-safe feature

    NASA Technical Reports Server (NTRS)

    Gaul, L. C.

    1965-01-01

    Check valve ensures unidirectional fluid flow and, in case of failure, vents the downstream fluid to the atmosphere and gives a positive indication of malfunction. This dual valve consists of a master check valve and a fail-safe valve.

  17. Lymphoma cells in cerebrospinal fluid confirmed by chromosome analysis

    PubMed Central

    Pearson, J; Ilgren, EB; Spriggs, AI

    1982-01-01

    Two cases of malignant lymphoma are reported, in which lymphoma cells were undergoing cell division in the cerebrospinal fluid. In each case it was possible to perform chromosome counts and karyotype analyses, and in this way to establish that a neoplastic clone was present. Images PMID:7174842

  18. Positive and negative effects of dielectric breakdown in transformer oil based magnetic fluids

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, Jong-Chul, E-mail: jclee01@gwnu.ac.kr; Lee, Won-Ho; Lee, Se-Hee

    The transformer oil based magnetic fluids can be considered as the next-generation insulation fluids because they offer exciting new possibilities to enhance dielectric breakdown voltage as well as heat transfer performance compared to pure transformer oils. In this study, we have investigated the dielectric breakdown strength of the fluids with the various volume concentrations of nanoparticles in accordance with IEC 156 standard and have tried to find the reason for changing the dielectric breakdown voltage of the fluids from the magnetic field analysis. It was found that the dielectric breakdown voltage of pure transformer oil is around 12 kV withmore » the gap distance of 1.5 mm. In the case of our transformer oil-based magnetic fluids with 0.08% < Φ < 0.6% (Φ means the volume concentration of magnetic nanoparticles), the dielectric breakdown voltage shows above 40 kV, which is 3.3 times higher positively than that of pure transformer oil. Negatively in the case when the volume concentration of magnetic nanoparticles is above 0.65%, the dielectric breakdown voltage decreases reversely. From the magnetic field analysis, the reason might be considered as two situations: the positive is for the conductive nanoparticles dispersed well near the electrodes, which play an important role in converting fast electrons to slow negatively charged particles, and the negative is for the agglomeration of the particles near the electrodes, which leads to the breakdown initiation.« less

  19. Electro-osmotic flow of power-law fluid and heat transfer in a micro-channel with effects of Joule heating and thermal radiation

    NASA Astrophysics Data System (ADS)

    Shit, G. C.; Mondal, A.; Sinha, A.; Kundu, P. K.

    2016-11-01

    A mathematical model has been developed for studying the electro-osmotic flow and heat transfer of bio-fluids in a micro-channel in the presence of Joule heating effects. The flow of bio-fluid is governed by the non-Newtonian power-law fluid model. The effects of thermal radiation and velocity slip condition have been examined in the case of hydrophobic channel. The Poisson-Boltzmann equation governing the electrical double layer field and a body force generated by the applied electric potential field are taken into consideration. The results presented here pertain to the case where the height of the channel is much greater than the thickness of electrical double layer comprising the Stern and diffuse layers. The expressions for flow characteristics such as velocity, temperature, shear stress and Nusselt number have been derived analytically under the purview of the present model. The results estimated on the basis of the data available in the existing scientific literatures are presented graphically. The effects of thermal radiation have an important bearing on the therapeutic procedure of hyperthermia, particularly in understanding the heat transfer in micro-channel in the presence of electric potential. The dimensionless Joule heating parameter has a reducing impact on Nusselt number for both pseudo-plastic and dilatant fluids, nevertheless its impact on Nusselt number is more pronounced for dilatant fluid. Furthermore, the effect of viscous dissipation has a significant role in controlling heat transfer and should not be neglected.

  20. Normal velocity freeze-out of the Richtmyer-Meshkov instability when a rarefaction is reflected

    NASA Astrophysics Data System (ADS)

    Wouchuk, J. G.; Sano, T.

    2015-02-01

    The Richtmyer-Meshkov instability (RMI) develops when a shock front hits a rippled contact surface separating two different fluids. After the incident shock refraction, a transmitted shock is always formed and another shock or a rarefaction is reflected back. The pressure-entropy-vorticity fields generated by the rippled wave fronts are responsible for the generation of hydrodynamic perturbations in both fluids. In linear theory, the contact surface ripple reaches an asymptotic normal velocity which is dependent on the incident shock Mach number, fluids density ratio, and compressibilities. It was speculated in the past about the possibility of getting a zero value for the asymptotic normal velocity, a phenomenon that was called "freeze-out" [G. Fraley, Phys. Fluids 29, 376 (1986), 10.1063/1.865722; K. Mikaelian, Phys. Fluids 6, 356 (1994), 10.1063/1.868091, A. L. Velikovich et al., Phys. Plasmas 8, 592 (2001), 10.1063/1.1335829]. In a previous paper, freeze-out was studied for the case when a shock is reflected at the contact surface [J. G. Wouchuk and K. Nishihara, Phys. Rev. E 70, 026305 (2004), 10.1103/PhysRevE.70.026305]. In this work the freeze-out of the RMI is studied for the case in which a rarefaction is reflected back. Two different regimes are found: nearly equal preshock densities at the interface at any shock intensity, and very large density difference for strong shocks. The contour curves that relate shock Mach number and preshock density ratio are obtained in both regimes for fluids with equal and different compressibilities. An analysis of the temporal evolution of different cases of freeze-out is shown. It is seen that the freeze-out is the result of the interaction between the unstable interface and the rippled wave fronts. As a general and qualitative criterion to look for freeze-out situations, it is seen that a necessary condition for freeze-out is the same orientation for the tangential velocities generated at each side of the contact surface at t =0 + . A comparison with the results of previous works is also shown.

  1. Oxygen supersaturated fluid using fine micro/nanobubbles

    PubMed Central

    Matsuki, Noriaki; Ishikawa, Takuji; Ichiba, Shingo; Shiba, Naoki; Ujike, Yoshihito; Yamaguchi, Takami

    2014-01-01

    Microbubbles show peculiar properties, such as shrinking collapse, long lifetime, high gas solubility, negative electric charge, and free radical production. Fluids supersaturated with various gases can be easily generated using microbubbles. Oxygen microbubble fluid can be very useful for oxygen delivery to hypoxic tissues. However, there have been no reports of comparative investigations into adding fluids containing oxygen fine micro/nanobubbles (OFM-NBs) to common infusion solutions in daily medical care. In this study, it was demonstrated that OFMNBs can generate oxygen-supersaturated fluids, and they may be sufficiently small to infuse safely into blood vessels. It was found that normal saline solution is preferable for generating an oxygen-rich infusion fluid, which is best administered as a 30-minute intravenous infusion. It was also concluded that dextran solution is suitable for drug delivery substances packing oxygen gas over a 1-hour intravenous infusion. In addition, normal saline solution containing OFMNBs was effective for improving blood oxygenation. Thus, the use of OFMNB-containing fluids is a potentially effective novel method for improving blood oxygenation in cases involving hypoxia, ischemic diseases, infection control, and anticancer chemoradiation therapies. PMID:25285003

  2. Oxygen supersaturated fluid using fine micro/nanobubbles.

    PubMed

    Matsuki, Noriaki; Ishikawa, Takuji; Ichiba, Shingo; Shiba, Naoki; Ujike, Yoshihito; Yamaguchi, Takami

    2014-01-01

    Microbubbles show peculiar properties, such as shrinking collapse, long lifetime, high gas solubility, negative electric charge, and free radical production. Fluids supersaturated with various gases can be easily generated using microbubbles. Oxygen microbubble fluid can be very useful for oxygen delivery to hypoxic tissues. However, there have been no reports of comparative investigations into adding fluids containing oxygen fine micro/nanobubbles (OFM-NBs) to common infusion solutions in daily medical care. In this study, it was demonstrated that OFMNBs can generate oxygen-supersaturated fluids, and they may be sufficiently small to infuse safely into blood vessels. It was found that normal saline solution is preferable for generating an oxygen-rich infusion fluid, which is best administered as a 30-minute intravenous infusion. It was also concluded that dextran solution is suitable for drug delivery substances packing oxygen gas over a 1-hour intravenous infusion. In addition, normal saline solution containing OFMNBs was effective for improving blood oxygenation. Thus, the use of OFMNB-containing fluids is a potentially effective novel method for improving blood oxygenation in cases involving hypoxia, ischemic diseases, infection control, and anticancer chemoradiation therapies.

  3. Coupled incompressible Smoothed Particle Hydrodynamics model for continuum-based modelling sediment transport

    NASA Astrophysics Data System (ADS)

    Pahar, Gourabananda; Dhar, Anirban

    2017-04-01

    A coupled solenoidal Incompressible Smoothed Particle Hydrodynamics (ISPH) model is presented for simulation of sediment displacement in erodible bed. The coupled framework consists of two separate incompressible modules: (a) granular module, (b) fluid module. The granular module considers a friction based rheology model to calculate deviatoric stress components from pressure. The module is validated for Bagnold flow profile and two standardized test cases of sediment avalanching. The fluid module resolves fluid flow inside and outside porous domain. An interaction force pair containing fluid pressure, viscous term and drag force acts as a bridge between two different flow modules. The coupled model is validated against three dambreak flow cases with different initial conditions of movable bed. The simulated results are in good agreement with experimental data. A demonstrative case considering effect of granular column failure under full/partial submergence highlights the capability of the coupled model for application in generalized scenario.

  4. [Dental periimplantitis distinctive features diagnostic in cases of minimal thyroid insufficiency].

    PubMed

    Shcherbakov, M V; Golovina, E S; Gil'miiarova, F N

    2008-01-01

    There were disclosed syndrome of minimal thyroid insufficiency in each fourth patient with dental periimplantitis and absence of thyroid gland dysfunction in case of mucositis of periimplantitis origin. The data were presented of minimal thyroid insufficiency manifestations in cases of inflammatory complications of dental implantations the indicator of which was the content of overall and free thyroxin in oral fluid. There were determined common and differentiating peculiarities of oral fluid homeostasis in cases of dental periimplantitis and mucositis of periimplantitis origin.

  5. Catheter drainage of pleural fluid collections and pneumothorax.

    PubMed

    Frendin, J; Obel, N

    1997-06-01

    A technique for virtually atraumatic placement of small size chest catheters for suction drainage of pleural effusions and pneumothorax in the dog and cat is described. Thirty-nine dogs and two cats were treated for pyothorax (10 cases), hydrothorax (eight), chylothorax (three), haemothorax (three), haemothorax/ pneumothorax (three) and pneumothorax (14). In all 41 cases, thin or viscous fluid and/or air were efficiently drained. The mean period of drainage was four days (range, 0.5 to 18 days). The average amount of fluid removed from each patient in 24 hours was 530 ml in pyothorax cases (range, 140 to 1100 ml) and 1300 ml in the other cases (range, 20 to 5000 ml). In 40 cases there were no complications related to the procedure. One dog with severe pleural adhesions was euthanased because of lung perforation and pneumothorax secondary to misplacement of the catheter.

  6. Impact on a Compressible Fluid

    NASA Technical Reports Server (NTRS)

    Egorov, L. T.

    1958-01-01

    Upon impact of a solid body on the plane surface of a fluid, there occurs on the vetted surface of the body an abrupt pressure rise which propagates into both media with the speed of sound. Below, we assume the case where the speed of propagation of sound in the body which falls on the surface of the fluid may be regarded as infinitely large in comparison with the speed of propagation of sound in the fluid; that is, we shall assume that the falling body is absolutely rigid. IN this case, the entire relative speed of the motion which takes place at the beginning of the impact is absorbed by the fluid. The hydrodynamic pressures arising thereby are propagated from the contact surface within the fluid with the speed of sound in the form of compression and expansion waves and are gradually damped. After this, they are dispersed like impact pressures, reach ever larger regions of the fluid remote fran the body and became equal to zero; in the fluid there remain hydrodynamic pressures corresponding to the motion of the body after the impact. Neglecting the forces of viscosity and taking into account, furthermore, that the motion of the fluid begins from a state of rest, according to Thomson's theorem, we may consider the motion of an ideal compressible fluid in the process of impact to be potential. We examine the case of impact upon the surface of a ccmpressible fluid of a flat plate of infinite extent or of a body, the immersed part of the surface of which may be called approximately flat. In this report we discuss the first phase of the impact pressure on the surface of a fluid, prior to the appearance of a cavity, since at this stage the hydrodynamic pressures reach their maximum values. Observations, after the fall of the bodies on the surface of the fluid, show that the free surface of the fluid at this stage is almost completely at rest if one does not take into account the small rise in the neighborhood of the boundaries of the impact surface.

  7. Nanoscale hydrodynamics near solids

    NASA Astrophysics Data System (ADS)

    Camargo, Diego; de la Torre, J. A.; Duque-Zumajo, D.; Español, Pep; Delgado-Buscalioni, Rafael; Chejne, Farid

    2018-02-01

    Density Functional Theory (DFT) is a successful and well-established theory for the study of the structure of simple and complex fluids at equilibrium. The theory has been generalized to dynamical situations when the underlying dynamics is diffusive as in, for example, colloidal systems. However, there is no such a clear foundation for Dynamic DFT (DDFT) for the case of simple fluids in contact with solid walls. In this work, we derive DDFT for simple fluids by including not only the mass density field but also the momentum density field of the fluid. The standard projection operator method based on the Kawasaki-Gunton operator is used for deriving the equations for the average value of these fields. The solid is described as featureless under the assumption that all the internal degrees of freedom of the solid relax much faster than those of the fluid (solid elasticity is irrelevant). The fluid moves according to a set of non-local hydrodynamic equations that include explicitly the forces due to the solid. These forces are of two types, reversible forces emerging from the free energy density functional, and accounting for impenetrability of the solid, and irreversible forces that involve the velocity of both the fluid and the solid. These forces are localized in the vicinity of the solid surface. The resulting hydrodynamic equations should allow one to study dynamical regimes of simple fluids in contact with solid objects in isothermal situations.

  8. Scaffolding for solving problem in static fluid: A case study

    NASA Astrophysics Data System (ADS)

    Koes-H, Supriyono; Muhardjito, Wijaya, Charisma P.

    2018-01-01

    Problem solving is one of the basic abilities that should be developed from learning physics. However, students still face difficulties in the process of non-routine problem-solving. Efforts are necessary to be taken in order to identify such difficulties and the solutions to solve them. An effort in the form of a diagnosis of students' performance in problem solving can be taken to identify their difficulties, and various instructional scaffolding supports can be utilized to eliminate the difficulties. This case study aimed to describe the students' difficulties in solving static fluid problems and the effort to overcome such difficulties through different scaffolding supports. The research subjects consisted of four 10-grade students of (Public Senior High School) SMAN 4 Malang selected by purposive sampling technique. The data of students' difficulties were collected via think-aloud protocol implemented on students' performance in solving non-routine static fluid problems. Subsequently, combined scaffolding supports were given to the students based on their particular difficulties. The research findings pointed out that there were several conceptual difficulties discovered from the students when solving static fluid problems, i.e. the use of buoyancy force formula, determination of all forces acting on a plane in a fluid, the resultant force on a plane in a fluid, and determination of a plane depth in a fluid. An effort that can be taken to overcome such conceptual difficulties is providing a combination of some appropriate scaffolding supports, namely question prompts with specific domains, simulation, and parallel modeling. The combination can solve students' lack of knowledge and improve their conceptual understanding, as well as help them to find solutions by linking the problems with their prior knowledge. According to the findings, teachers are suggested to diagnose the students' difficulties so that they can provide an appropriate combination of scaffolding to support their students in finding the solutions.

  9. Intrapartum amnioinfusion for meconium-stained fluid: meta-analysis of prospective clinical trials.

    PubMed

    Pierce, J; Gaudier, F L; Sanchez-Ramos, L

    2000-06-01

    To evaluate the effectiveness of intrapartum prophylactic amnioinfusion in pregnancies complicated by meconium-stained amniotic fluid. We identified prospective clinical trials of amnioinfusion in pregnancies complicated by meconium-stained amniotic fluid (AF) published in English by using computerized databases, references in published studies, and index reviews. We analyzed prospective studies of intrapartum amnioinfusion for meconium-stained AF. In every case, group allocation was based exclusively on meconium in AF. Only published studies with clearly documented outcome data were included. The trials were evaluated for meconium below the vocal cords, meconium aspiration syndrome, fetal acidemia, cesarean delivery, and postpartum endometritis. Each trial was evaluated for the quality of its methodology, inclusion and exclusion criteria, adequacy of randomization, amnioinfusion protocols, definition of outcomes, and statistical analyses. Thirteen studies met inclusion criteria for our systematic review. Odds ratios (ORs) with their 95% confidence intervals (CIs) were calculated for each outcome. Estimates of ORs and risk differences for dichotomous outcomes were calculated using random and fixed-effects models. We tested for homogeneity across the studies. We found that intrapartum amnioinfusion significantly reduced the frequency of meconium aspiration syndrome (OR 0.30; 95% CI 0.19, 0. 46), of meconium below the vocal cords, and neonatal acidemia. Subjects allocated to receive amnioinfusion also had a significantly lower overall cesarean rate (OR 0.74, 95% CI 0.59, 0.93) without increased postpartum endometritis. Amnioinfusion in cases of meconium-stained fluid significantly improves neonatal outcome, lowers the cesarean delivery rate, and does not increase the postpartum endometritis rate.

  10. Nonlocal and nonlinear electrostatics of a dipolar Coulomb fluid.

    PubMed

    Sahin, Buyukdagli; Ralf, Blossey

    2014-07-16

    We study a model Coulomb fluid consisting of dipolar solvent molecules of finite extent which generalizes the point-like dipolar Poisson-Boltzmann model (DPB) previously introduced by Coalson and Duncan (1996 J. Phys. Chem. 100 2612) and Abrashkin et al (2007 Phys. Rev. Lett. 99 077801). We formulate a nonlocal Poisson-Boltzmann equation (NLPB) and study both linear and nonlinear dielectric response in this model for the case of a single plane geometry. Our results shed light on the relevance of nonlocal versus nonlinear effects in continuum models of material electrostatics.

  11. Turbulence coefficients and stability studies for the coaxial flow or dissimiliar fluids. [gaseous core nuclear reactors

    NASA Technical Reports Server (NTRS)

    Weinstein, H.; Lavan, Z.

    1975-01-01

    Analytical investigations of fluid dynamics problems of relevance to the gaseous core nuclear reactor program are presented. The vortex type flow which appears in the nuclear light bulb concept is analyzed along with the fluid flow in the fuel inlet region for the coaxial flow gaseous core nuclear reactor concept. The development of numerical methods for the solution of the Navier-Stokes equations for appropriate geometries is extended to the case of rotating flows and almost completes the gas core program requirements in this area. The investigations demonstrate that the conceptual design of the coaxial flow reactor needs further development.

  12. Management of diarrhea in a DTU.

    PubMed

    Kamala, C S; Vishwanathakumar, H M; Shetti, P M; Anand, N

    1996-10-01

    A retrospective review of cases seen in the Diarrhea Treatment and Training Unit (DTU) of Bangalore (India) Medical College's Vani Vilas Children's Hospital during 1992-1994 confirmed the efficacy of the standard case management approach. This strategy entails oral rehydration therapy (ORT), continued feeding, and selective use of intravenous fluids and antibiotics. Of the 7966 children (4374 males and 3592 females) reporting to the DTU during the 2-year study period, only 2412 (30.5%) had received oral rehydration solution (ORS) or home-available fluids before admission. Acute watery diarrhea was present in 7316 cases (91.84%). Death occurred in 59 acute watery diarrhea cases, 6 dysentery cases, and 7 persistent diarrhea cases. The average time for cases managed in the ORT area was 2 hours and 45 minutes, while the hospital stay for admitted cases averaged 3 days. In 6957 cases (87.33%), ORS was sufficient treatment. Of the 1009 children (12.67%) who required intravenous fluids, 254 had dehydration attributable to conditions such as persistent vomiting and inability to drink due to oral thrush. Only the 512 children (6.2%) with cholera and dysentery received antibiotics. Of the 72 children who died (case fatality rate, 0.9%), 43 had associated severe malnutrition with pneumonia and anemia, 14 had a central nervous system infection, and 13 had septicemia; in only 2 cases could death be directly ascribed to diarrheal disease. One of these cases was due to shigella encephalopathy and the other to severe dehydration with acidosis. The average cost of treatment per patient was Rs 2.91 when only ORS was used compared with Rs 24.28 when intravenous rehydration was required. The finding that less than one-third of children had received ORS before admission suggests a need for the establishment of more DTUs in large hospitals that can train community-based health personnel in diarrhea case management.

  13. Vein mineralizations - archives of paleo-fluid systems in the Thuringian basin (Germany)

    NASA Astrophysics Data System (ADS)

    Abratis, M.; Brey, M.; Fritsch, S.; Majzlan, J.; Viereck-Götte, L.

    2012-04-01

    We investigate vein mineralizations within and around the Thuringian basin (Germany) in order to characterize paleo-fluid systems that have been active in the basin. By investigating the composition, temperature, origin, age and evolution of paleo-fluids in the Thuringian basin as a model case, we aim for comprehensive understanding of the character of mineralized fluid systems in sedimentary basins in general and their evolution over geological time scales. Mineralizations along faults are archives for the composition of fluids which intruded the basin and circulated within it millions of years ago. These mineralizations give information on the physical and chemical characteristics of the related fluids as well as on their evolution with time during basin evolution. Mapping of mineralizations in space and time and comparison with the present-day fluid circulation system allows for recognition of the paleo-fluid dynamics and high temperature fluid influx pathways. The chemical characteristics of vein-related mineralizations are proxies for the paleo-fluid sources and their solution load. Methods implied comprise bulk rock analyses (petrography, XRD, XRF, ICP-MS), mineral analyses (EPMA, LA-ICP-MS), fluid inclusion measurements (microthermometry, Raman spectroscopy, ion chromatography) and isotope studies (O, H, C, S, Sr). Vein-related mineralizations within the Mesozoic sediments of the basin occur predominantly along WNW-ESE trending fault systems and comprise mainly carbonates and sulfates. Mineralizations within the basin-confining uplifted Variscan basement rocks and lowermost sedimentary units (Zechstein) show also (Fe-, Cu-, Zn-, As-, Sb-) sulfides, (Fe-, Mn-) oxides, fluorite and barite. The present study is part of INFLUINS, a BMBF-funded project bundle which is dedicated to comprehensive description and understanding of the fluid systems within the Thuringian basin in time and space.

  14. Fluid chemistry and evolution of hydrothermal fluids in an Archaean transcrustal fault zone network: The case of the Cadillac Tectonic Zone, Abitibi greenstone belt, Canada

    USGS Publications Warehouse

    Neumayr, P.; Hagemann, S.G.; Banks, D.A.; Yardley, B.W.D.; Couture, J.-F.; Landis, G.P.; Rye, R.

    2007-01-01

    Detailed fluid geochemistry studies on hydrothermal quartz veins from the Rouyn-Noranda and Val-d'Or areas along the transcrustal Cadillac Tectonic Zone (CTZ) indicate that unmineralized (with respect to gold) sections of the CTZ contained a distinct CO2-dominated, H2S-poor hydrothermal fluid. In contrast, both gold mineralized sections of the CTZ (e.g., at Orenada #2) and associated higher order shear zones have a H2O-CO2 ?? CH4-NaCl hydrothermal fluid. Their CO2/H2S ratios indicate H2S-rich compositions. The Br/Cl compositions in fluid inclusions trapped in these veins indicate that hydrothermal fluids have been equilibrated with the crust. Oxygen isotope ratios from hydrothermal quartz veins in the CTZ are consistently 2??? more enriched than those of associated higher order shear zones, which are interpreted to be a function of greater fluid/rock ratios in the CTZ and lower fluid/rock ratios, and more efficient equilibration of the hydrothermal fluid with the wall rock, in higher order shear zones. An implication from this study is that the lower metal endowment of the transcrustal CTZ, when compared with the higher metal endowment in higher order shear zones (ratio of about 1 : 1000), may be the result of the lack of significant amounts of H2O-H2S rich fluids in most of the CTZ. In contrast, gold mineralization in the higher order shear zones appear to be controlled by the high H2S activity of the aqueous fluids, because gold was likely transported in a bisulfide complex and was deposited during sulfidation reactions in the wall rock and phase separation in the quartz veins. ?? 2007 NRC Canada.

  15. Fluid inclusion chemistry of adularia-sericite epithermal Au-Ag deposits of the southern Hauraki Goldfield, New Zealand

    USGS Publications Warehouse

    Simpson, Mark P.; Strmic Palinkas, Sabina; Mauk, Jeffrey L.; Bodnar, Robert J.

    2015-01-01

    LA-ICP-MS analyses show that in some cases different fluid inclusion assemblages (FIAs) within a single sample trapped fluids with variable chemistries. These differences likely reflect modification of a single parent fluid through mineral dissolution and precipitation, water/rock interactions, boiling and vapor loss, conductive cooling, and mixing.

  16. Self-organizing maps in geothermal exploration-A new approach for understanding geochemical processes and fluid evolution

    NASA Astrophysics Data System (ADS)

    Brehme, Maren; Bauer, Klaus; Nukman, Mochamad; Regenspurg, Simona

    2017-04-01

    Understanding geochemical processes is an important part of geothermal exploration to get information about the source and evolution of geothermal fluids. However, in most cases knowledge of fluid properties is based on few parameters determined in samples from the shallow subsurface. This study presents a new approach that allows to conclude from the combination of a variety of these data on processes occurring at depth in a geothermal reservoir. The neural network clustering technique called "self-organizing maps" (SOMs) successfully distinguished two different geothermal settings based on a hydrochemical database and disclosed the source, evolution and flow pathways of geothermal fluids. Scatter plots, as shown in this study, are appropriate presentations of element concentrations and the chemical interaction of water and rock at depth. One geological setting presented here is marked by fault dominated fluid pathways and minor influence of volcanic affected fluids with high concentrations of HCO3, Ca and Sr. The second is a magmatically dominated setting showing strong alteration features in volcanic rocks and accommodates acidic fluids with high SO4 and Si concentrations. Former studies, i.e., Giggenbach (1988), suggested Cl, HCO3 and SO4 to be generally the most important elements for understanding hydrochemical processes in geothermal reservoirs. Their relation has been widely used to classify different water types in geothermal fields. However, this study showed that non-standard elements are at least of same importance to reveal different fluid types in geothermal systems. Therefore, this study is an extended water classification approach using SOM for element correlations. SOM have been proven to be a successful method for analyzing even relatively small hydrochemical datasets in geothermal applications.

  17. Fluid mechanics as a driver of tissue-scale mechanical signaling in organogenesis.

    PubMed

    Gilbert, Rachel M; Morgan, Joshua T; Marcin, Elizabeth S; Gleghorn, Jason P

    2016-12-01

    Organogenesis is the process during development by which cells self-assemble into complex, multi-scale tissues. Whereas significant focus and research effort has demonstrated the importance of solid mechanics in organogenesis, less attention has been given to the fluid forces that provide mechanical cues over tissue length scales. Fluid motion and pressure is capable of creating spatial gradients of forces acting on cells, thus eliciting distinct and localized signaling patterns essential for proper organ formation. Understanding the multi-scale nature of the mechanics is critically important to decipher how mechanical signals sculpt developing organs. This review outlines various mechanisms by which tissues generate, regulate, and sense fluid forces and highlights the impact of these forces and mechanisms in case studies of normal and pathological development.

  18. Electrostatic interaction between dissimilar colloids at fluid interfaces

    NASA Astrophysics Data System (ADS)

    Majee, Arghya; Schmetzer, Timo; Bier, Markus

    2018-04-01

    The electrostatic interaction between two nonidentical, moderately charged colloids situated in close proximity of each other at a fluid interface is studied. By resorting to a well-justified model system, this problem is analytically solved within the framework of linearized Poisson-Boltzmann density functional theory. The resulting interaction comprises a surface and a line part, both of which, as functions of the interparticle separation, show a rich behavior including monotonic as well as nonmonotonic variations. In almost all cases, these variations cannot be captured correctly by using the superposition approximation. Moreover, expressions for the surface tensions, the line tensions and the fluid-fluid interfacial tension, which are all independent of the interparticle separation, are obtained. Our results are expected to be particularly useful for emulsions stabilized by oppositely charged particles.

  19. A simulation for teaching the basic and clinical science of fluid therapy.

    PubMed

    Rawson, Richard E; Dispensa, Marilyn E; Goldstein, Richard E; Nicholson, Kimberley W; Vidal, Noni Korf

    2009-09-01

    The course "Management of Fluid and Electrolyte Disorders" is an applied physiology course taught using lectures and paper-based cases. The course approaches fluid therapy from both basic science and clinical perspectives. While paper cases provide a basis for application of basic science concepts, they lack key components of genuine clinical cases that, by nature, are diverse, change over time, and respond in unique ways to therapeutic interventions. We developed a dynamic model using STELLA software that simulates normal and abnormal fluid and electrolyte balance in the dog. Students interact, not with the underlying model, but with a user interface that provides sufficient data (skin turgor, chemistry panel, etc.) for the clinical assessment of patients and an opportunity for treatment. Students administer fluids and supplements, and the model responds in "real time," requiring regular reassessment and, potentially, adaptation of the treatment strategy. The level of success is determined by clinical outcome, including improvement, deterioration, or death. We expected that the simulated cases could be used to teach both the clinical and basic science of fluid therapy. The simulation provides exposure to a realistic clinical environment, and students tend to focus on this aspect of the simulation while, for the most part, ignoring an exploration of the underlying physiological basis for patient responses. We discuss how the instructor's expertise can provide sufficient support, feedback, and scaffolding so that students can extract maximum understanding of the basic science in the context of assessing and treating at the clinical level.

  20. Fluid Dynamics of the Heart and its Valves

    NASA Astrophysics Data System (ADS)

    Peskin, Charles S.

    1997-11-01

    The fluid dynamics of the heart involve the interaction of blood, a viscous incompressible fluid, with the flexible, elastic, fiber-reinforced heart valve leaflets that are immersed in that fluid. Neither the fluid motion nor the valve leaflet motion are known in advance: both must be computed simultaneously by solving their coupled equations of motion. This can be done by the immersed boundary method(Peskin CS and McQueen DM: A general method for the computer simulation of biological systems interacting with fluids. In: Biological Fluid Dynamics (Ellington CP and Pedley TJ, eds.), The Company of Biologists Limited, Cambridge UK, 1995, pp. 265-276.), which can be extended to incorporate the contractile fiber architecture of the muscular heart walls as well as the valve leaflets and the blood. In this way we arrive at a three-dimensional computer model of the heart(Peskin CS and McQueen DM: Fluid dynamics of the heart and its valves. In: Case Studies in Mathematical Modeling: Ecology, Physiology, and Cell Biology (Othmer HG, Adler FR, Lewis MA, and Dallon JC, eds.), Prentice-Hall, Englewood Cliffs NJ, 1996, pp. 309-337.), which can be used as a test chamber for the design of prosthetic cardiac valves, and also to study the function of the heart in health and in disease. Numerical solutions of the equations of cardiac fluid dynamics obtained by the immersed boundary method will be presented in the form of a video animation of the beating heart.

  1. Postmortem computed tomography and magnetic resonance imaging facilitates forensic autopsy in a fatal case of poisoning with formic acid, diphenhydramine, and ethanol.

    PubMed

    Berger, Florian; Steuer, Andrea E; Rentsch, Katharina; Gascho, Dominic; Stamou, Stamatios; Schärli, Sarah; Thali, Michael J; Krämer, Thomas; Flach, Patricia M

    2016-09-01

    A case of fatal poisoning by ingesting formic acid, diphenhydramine, and ethanol by a 25-year-old woman who committed suicide is presented. Prior to autopsy, postmortem computed tomography and postmortem magnetic resonance tomography were performed and revealed severe damage to the stomach, the left thoracic wall, and parts of the liver. Imaging detected acid-induced fluid-fluid level within the thoracic cavity (fat-equivalent fluid and necrotic pleural effusion). This case report illustrates that postmortem cross-sectional imaging may facilitate dissection of severely damaged or complex regions, and may provide additional information compared to autopsy and toxicological examinations alone.

  2. Predictive Role of ADA in Bronchoalveolar Lavage Fluid in Making the Diagnosis of Pulmonary Tuberculosis.

    PubMed

    Binesh, Fariba; Halvani, Abolhassan

    2013-01-01

    Current diagnostic tests for tuberculosis (TB) are time-consuming. The aim of this study was to evaluate the diagnostic usefulness of ADA in bronchoalveolar lavage fluid in patients with pulmonary TB. A cross-sectional study was performed in Yazd, Iran, between 2009 and 2010. Patients suspected of pulmonary TB with negative sputum smear for AFB were included in the study. Mean ADA levels in BAL fluids were measured and compared between study groups. Sixty-three patients were enrolled in the study among which 15 cases had pulmonary TB, 33 had pulmonary diseases other than TB, and 15 subjects with normal bronchoscopy results were considered as controls. Mean ADA levels in BAL fluid were 4.13 ± 2.55, 2.42 ± 1.06, and 1.93 ± 0.88, respectively. This rate was significantly higher in the pulmonary TB group compared to the other two groups (P = 0.001). Using ROC curve with a cut-off value of 3.5 IU/L, the highest sensitivity (57%) and specificity (84%) were obtained in diagnosis of TB. The results showed that although ADA activity in BAL fluid of pulmonary TB patients was higher than those seen in other diseases, a negative test does not rule out pulmonary TB.

  3. Theories of binary fluid mixtures: from phase-separation kinetics to active emulsions

    NASA Astrophysics Data System (ADS)

    Cates, Michael E.; Tjhung, Elsen

    2018-02-01

    Binary fluid mixtures are examples of complex fluids whose microstructure and flow are strongly coupled. For pairs of simple fluids, the microstructure consists of droplets or bicontinuous demixed domains and the physics is controlled by the interfaces between these domains. At continuum level, the structure is defined by a composition field whose gradients which are steep near interfaces drive its diffusive current. These gradients also cause thermodynamic stresses which can drive fluid flow. Fluid flow in turn advects the composition field, while thermal noise creates additional random fluxes that allow the system to explore its configuration space and move towards the Boltzmann distribution. This article introduces continuum models of binary fluids, first covering some well-studied areas such as the thermodynamics and kinetics of phase separation, and emulsion stability. We then address cases where one of the fluid components has anisotropic structure at mesoscopic scales creating nematic (or polar) liquid-crystalline order; this can be described through an additional tensor (or vector) order parameter field. We conclude by outlining a thriving area of current research, namely active emulsions, in which one of the binary components consists of living or synthetic material that is continuously converting chemical energy into mechanical work.

  4. The Perfectly Matched Layer absorbing boundary for fluid-structure interactions using the Immersed Finite Element Method.

    PubMed

    Yang, Jubiao; Yu, Feimi; Krane, Michael; Zhang, Lucy T

    2018-01-01

    In this work, a non-reflective boundary condition, the Perfectly Matched Layer (PML) technique, is adapted and implemented in a fluid-structure interaction numerical framework to demonstrate that proper boundary conditions are not only necessary to capture correct wave propagations in a flow field, but also its interacted solid behavior and responses. While most research on the topics of the non-reflective boundary conditions are focused on fluids, little effort has been done in a fluid-structure interaction setting. In this study, the effectiveness of the PML is closely examined in both pure fluid and fluid-structure interaction settings upon incorporating the PML algorithm in a fully-coupled fluid-structure interaction framework, the Immersed Finite Element Method. The performance of the PML boundary condition is evaluated and compared to reference solutions with a variety of benchmark test cases including known and expected solutions of aeroacoustic wave propagation as well as vortex shedding and advection. The application of the PML in numerical simulations of fluid-structure interaction is then investigated to demonstrate the efficacy and necessity of such boundary treatment in order to capture the correct solid deformation and flow field without the requirement of a significantly large computational domain.

  5. Numerical schemes for anomalous diffusion of single-phase fluids in porous media

    NASA Astrophysics Data System (ADS)

    Awotunde, Abeeb A.; Ghanam, Ryad A.; Al-Homidan, Suliman S.; Tatar, Nasser-eddine

    2016-10-01

    Simulation of fluid flow in porous media is an indispensable part of oil and gas reservoir management. Accurate prediction of reservoir performance and profitability of investment rely on our ability to model the flow behavior of reservoir fluids. Over the years, numerical reservoir simulation models have been based mainly on solutions to the normal diffusion of fluids in the porous reservoir. Recently, however, it has been documented that fluid flow in porous media does not always follow strictly the normal diffusion process. Small deviations from normal diffusion, called anomalous diffusion, have been reported in some experimental studies. Such deviations can be caused by different factors such as the viscous state of the fluid, the fractal nature of the porous media and the pressure pulse in the system. In this work, we present explicit and implicit numerical solutions to the anomalous diffusion of single-phase fluids in heterogeneous reservoirs. An analytical solution is used to validate the numerical solution to the simple homogeneous case. The conventional wellbore flow model is modified to account for anomalous behavior. Example applications are used to show the behavior of wellbore and wellblock pressures during the single-phase anomalous flow of fluids in the reservoirs considered.

  6. Large Eddy Simulations of the Tilted Rig Experiment: A Two-dimensional Rayleigh-Taylor Instability Case

    NASA Astrophysics Data System (ADS)

    Rollin, Bertrand; Denissen, Nicholas A.; Reisner, Jon M.; Andrews, Malcolm J.

    2012-11-01

    The tilted rig experiment is a derivative of the rocket rig experiment designed to investigate turbulent mixing induced by the Rayleigh-Taylor (RT) instability. A tank containing two fluids of different densities is accelerated downwards between two parallel guiding rods by rocket motors. The acceleration is such that the pressure and density gradients face opposite directions at the fluids interface, creating a Rayleigh-Taylor unstable configuration. The rig is tilted such that the tank is initially at an angle and the acceleration is not perpendicular to the fluids interface when the rockets fire. This results in a two dimensional Rayleigh-Taylor instability case where the fluids experience RT mixing and a bulk overturning motion. The tilted rig is therefore a valuable experiment to help calibrating two-dimensional mixing models. Large Eddy Simulations of the tilted rig experiments will be compared to available experimental results. A study of the behavior of turbulence variables relevant to turbulence modeling will be presented. LA-UR 12-23829. This work was performed for the U.S. Department of Energy by Los Alamos National Laboratory under Contract No.DEAC52- 06NA2-5396.

  7. The motions and wave fields produced by an ellipse moving through a stratified fluid

    NASA Astrophysics Data System (ADS)

    Hurlen, Erik Curtis

    Solid-fluid interactions are ubiquitous in nature, from leaves falling from trees to fish swimming in the ocean. This dissertation examines a certain class of these interactions, namely asymmetric objects moving through stratified fluids. In the first part, the equations of motion are derived and subsequently solved for a displaced neutrally buoyant ellipse of varying aspect ratio. This is accomplished by using a spectral numerical algorithm, although in certain specific cases the equations can also be solved analytically using Laplace transform techniques. Experiments are conducted to which these analytical and numerical results are compared. General quantitative agreement is observed between the two sets of data. The discrepancies which are observed are consistent with both previous research and expectation. In the second part, the focus is shifted from the solid to the fluid, as the primary concern is now the wave field produced by these moving bodies. The spectral method developed in the first part is easily adapted to this second situation, in which the drag forces on the solid are also easily extracted. The results from this section are compared to previous results, and match very well. The results are then expanded to cases which have not been previously studied.

  8. Influence of impeller and diffuser geometries on the lateral fluid forces of whirling centrifugal impeller

    NASA Technical Reports Server (NTRS)

    Ohashi, Hideo; Sakurai, Akira; Nishihama, Jiro

    1989-01-01

    Lateral fluid forces on two-dimensional centrifugal impellers, which whirl on a circular orbit in a vaneless diffuser, were reported. Experiments were further conducted for the cases in which a three-dimensional centrifugal impeller, a model of the boiler feed pump, whirls in vaneless and vaned diffusers. The influence of the clearance configuration between the casing and front shroud of the impeller was also investigated. The result indicated that the fluid dynamic interaction between the impeller and the guide vanes induces quite strong fluctuating fluid forces to the impeller, but nevertheless its influence on radial and tangential force components averaged over a whirling orbit is relatively small.

  9. Hydrodynamic coupling of two sharp-edged beams vibrating in a viscous fluid

    PubMed Central

    Intartaglia, Carmela; Soria, Leonardo; Porfiri, Maurizio

    2014-01-01

    In this paper, we study flexural vibrations of two thin beams that are coupled through an otherwise quiescent viscous fluid. While most of the research has focused on isolated beams immersed in placid fluids, inertial and viscous hydrodynamic coupling is ubiquitous across a multitude of engineering and natural systems comprising arrays of flexible structures. In these cases, the distributed hydrodynamic loading experienced by each oscillating structure is not only related to its absolute motion but is also influenced by its relative motion with respect to the neighbouring structures. Here, we focus on linear vibrations of two identical beams for low Knudsen, Keulegan–Carpenter and squeeze numbers. Thus, we describe the fluid flow using unsteady Stokes hydrodynamics and we propose a boundary integral formulation to compute pertinent hydrodynamic functions to study the fluid effect. We validate the proposed theoretical approach through experiments on centimetre-size compliant cantilevers that are subjected to underwater base-excitation. We consider different geometric arrangements, beam interdistances and excitation frequencies to ascertain the model accuracy in terms of the relevant non-dimensional parameters. PMID:24511249

  10. Influence of a thin compressible insoluble liquid film on the eddy currents generated by interacting surface waves

    NASA Astrophysics Data System (ADS)

    Parfenyev, Vladimir M.; Vergeles, Sergey S.

    2018-06-01

    Recently the generation of eddy currents by interacting surface waves was observed experimentally. The phenomenon provides the possibility for manipulation of particles which are immersed in the fluid. The analysis shows that the amplitude of the established eddy currents produced by stationary surface waves does not depend on the fluid viscosity in the free surface case. The currents become parametrically larger, being inversely proportional to the square root of the fluid viscosity in the case when the fluid surface is covered by an almost incompressible thin liquid (i.e., shear elasticity is zero) film formed by an insoluble agent with negligible internal viscous losses as compared to the dissipation in the fluid bulk. Here we extend the theory for a thin insoluble film with zero shear elasticity and small shear and dilational viscosities on the case of an arbitrary elastic compression modulus. We find both contributions into the Lagrangian motion of passive tracers, which are the advection by the Eulerian vertical vorticity and the Stokes drift. Whereas the Stokes drift contribution preserves its value for the free surface case outside a thin viscous sublayer, the Eulerian vertical vorticity strongly depends on the fluid viscosity at high values of the film compression modulus. The Stokes drift acquires a strong dependence on the fluid viscosity inside the viscous sublayer; however, the change is compensated by an opposite change in the Eulerian vertical vorticity. As a result, the vertical dependence of the intensity of eddy currents is given by a sum of two decaying exponents with both decrements being of the order of the wave number. The decrements are numerically different, so the Eulerian contribution becomes dominant at some depth for the surface film with any compression modulus.

  11. Forced convective heat transfer in boundary layer flow of Sisko fluid over a nonlinear stretching sheet.

    PubMed

    Munir, Asif; Shahzad, Azeem; Khan, Masood

    2014-01-01

    The major focus of this article is to analyze the forced convective heat transfer in a steady boundary layer flow of Sisko fluid over a nonlinear stretching sheet. Two cases are studied, namely (i) the sheet with variable temperature (PST case) and (ii) the sheet with variable heat flux (PHF case). The heat transfer aspects are investigated for both integer and non-integer values of the power-law index. The governing partial differential equations are reduced to a system of nonlinear ordinary differential equations using appropriate similarity variables and solved numerically. The numerical results are obtained by the shooting method using adaptive Runge Kutta method with Broyden's method in the domain[Formula: see text]. The numerical results for the temperature field are found to be strongly dependent upon the power-law index, stretching parameter, wall temperature parameter, material parameter of the Sisko fluid and Prandtl number. In addition, the local Nusselt number versus wall temperature parameter is also graphed and tabulated for different values of pertaining parameters. Further, numerical results are validated by comparison with exact solutions as well as previously published results in the literature.

  12. Soft lubrication: The elastohydrodynamics of nonconforming and conforming contacts

    NASA Astrophysics Data System (ADS)

    Skotheim, J. M.; Mahadevan, L.

    2005-09-01

    We study the lubrication of fluid-immersed soft interfaces and show that elastic deformation couples tangential and normal forces and thus generates lift. We consider materials that deform easily, due to either geometry (e.g., a shell) or constitutive properties (e.g., a gel or a rubber), so that the effects of pressure and temperature on the fluid properties may be neglected. Four different system geometries are considered: a rigid cylinder moving parallel to a soft layer coating a rigid substrate; a soft cylinder moving parallel to a rigid substrate; a cylindrical shell moving parallel to a rigid substrate; and finally a cylindrical conforming journal bearing coated with a thin soft layer. In addition, for the particular case of a soft layer coating a rigid substrate, we consider both elastic and poroelastic material responses. For all these cases, we find the same generic behavior: there is an optimal combination of geometric and material parameters that maximizes the dimensionless normal force as a function of the softness parameter η =hydrodynamicpressure/elasticstiffness=surfacedeflection/gapthickness, which characterizes the fluid-induced deformation of the interface. The corresponding cases for a spherical slider are treated using scaling concepts.

  13. An unusual case of recurrent Guillain-Barré syndrome with normal cerebrospinal fluid protein levels: a case report.

    PubMed

    Gunatilake, Sonali Sihindi Chapa; Gamlath, Rohitha; Wimalaratna, Harith

    2016-09-05

    Guillain-Barré syndrome is an acquired polyradiculo-neuropathy, often preceded by an antecedent event. It is a monophasic disease but a recurrence rate of 1-6 % is documented in a subset group of patients. Patients with Guillain-Barré syndrome show cerebrospinal fluid albuminocytologic dissociation. Normal cerebrospinal fluid protein levels during both initial and recurrent episodes of Guillain-Barré syndrome is a rare occurrence and has not been described earlier in the literature. Twenty-five-year-old Sri Lankan female with past history of complete recovery following an acute inflammatory demyelinating polyneuropathy (AIDP) variant of Guillain-Barré syndrome 12 years back presented with acute, ascending symmetrical flaccid quadriparasis extending to bulbar muscles, bilateral VII cranial nerves and respiratory compromise needing mechanical ventilation. Nerve conduction study revealed AIDP variant of Guillain-Barré syndrome. Cerebrospinal fluid analysis done after 2 weeks were normal during both episodes without albuminocytologic dissociation. She was treated with intravenous immunoglobulin resulting in a remarkable recovery. Both episodes had a complete clinical recovery in three and four months' time respectively, rather a faster recovery than usually expected. Recurrence of Guillain-Barré syndrome can occur in a subset of patients with Guillain-Barré syndrome even after many years of asymptomatic period. Normal cerebrospinal fluid profile does not exclude Guillain-Barré syndrome and may occur in subsequent recurrences of Guillain-Barré syndrome arising the need for further studies to identify the pathophysiology and the possibility of a different subtype of Guillain-Barré syndrome.

  14. Arthritis secondary to meningococcal disease: A case series of 7 patients.

    PubMed

    Masson-Behar, Vanina; Jacquier, Hervé; Richette, Pascal; Ziza, Jean-Marc; Zeller, Valérie; Rioux, Christophe; Coustet, Baptiste; Dieudé, Philippe; Ottaviani, Sébastien

    2017-07-01

    Arthritis secondary to invasive meningococcemia is rare and has been described as a direct result of bacteremia or as immunoallergic-type arthritis, related to the immune complex. Only a few case series have been reported.This multicenter study aimed to describe the clinical characteristics and therapeutic outcomes of arthritis secondary to meningococcal infection.We performed a 5-year retrospective study. We included all patients with inflammatory joint symptoms and proven meningococcal disease defined by the identification of Neisseria meningitidis in blood, cerebrospinal fluid, or synovial fluid. Septic arthritis was defined by the identification of N meningitidis in joint fluid. Immune-mediated arthritis was considered to be arthritis occurring after at least 1 day of invasive meningococcal disease without positive joint fluid culture.A total of 7 patients (5 males) with joint symptoms and meningococcal disease were identified. The clinical presentation was mainly oligoarticular and the knee was the most frequent joint site. Five patients had septic arthritis and 4 had immune-mediated arthritis; 2 had septic arthritis followed by immune-mediated arthritis. Immune-mediated arthritis occurred 3 to 7 days after meningococcal meningitis, and treatment with nonsteroidal anti-inflammatory drugs (NSAIDs) led to improvement without complications.Physicians must be vigilant to the different clinical presentations in patients with arthritis associated with invasive meningococcal disease. If immune-mediated arthritis is suspected, NSAIDs are usually efficient.

  15. A comparative study on heat and mass transfer of the Blasius and Falkner-Skan flow of a bio-convective Casson fluid past a wedge

    NASA Astrophysics Data System (ADS)

    Raju, C. S. K.; Sandeep, N.

    2016-11-01

    Nowadays, many theoretical models are available for analyzing the heat and mass transfer of flows through different geometries. Nevertheless, it is challenging for researchers to choose among these models, the most suitable for a particular geometry. In addition to this, the extrinsic magnetic field is capable to set the thermal and physical properties of magnetic fluids and regulate the flow and heat transfer characteristics. The strength of the applied magnetic field affects the thermal conductivity of the fluids and makes it anisotropic. With this incentive, we attempt to study the thermophoresis and Brownian motion effects on the magnetohydrodynamic radiative Casson fluid flow over a wedge filled with gyrotactic microorganisms by considering the Blasius and Falkner-Skan models. Numerical solutions are offered graphically as well as in tabular form with the aid of Runge-Kutta and Newton's methods. Results for Blasius and Falkner-Skan flow cases are exhibited through plots for the parameters of concern. For real life applications, we also calculated the heat and mass transfer rates. It is observed that thermal and concentration boundary layers are not uniform for Falkner-Skan and Blasius flow cases. It is also observed that the heat and mass transfer rate is high in Falkner-Skan flow when compared with Blasius flow.

  16. Attractors of equations of non-Newtonian fluid dynamics

    NASA Astrophysics Data System (ADS)

    Zvyagin, V. G.; Kondrat'ev, S. K.

    2014-10-01

    This survey describes a version of the trajectory-attractor method, which is applied to study the limit asymptotic behaviour of solutions of equations of non-Newtonian fluid dynamics. The trajectory-attractor method emerged in papers of the Russian mathematicians Vishik and Chepyzhov and the American mathematician Sell under the condition that the corresponding trajectory spaces be invariant under the translation semigroup. The need for such an approach was caused by the fact that for many equations of mathematical physics for which the Cauchy initial-value problem has a global (weak) solution with respect to the time, the uniqueness of such a solution has either not been established or does not hold. In particular, this is the case for equations of fluid dynamics. At the same time, trajectory spaces invariant under the translation semigroup could not be constructed for many equations of non-Newtonian fluid dynamics. In this connection, a different approach to the construction of trajectory attractors for dissipative systems was proposed in papers of Zvyagin and Vorotnikov without using invariance of trajectory spaces under the translation semigroup and is based on the topological lemma of Shura-Bura. This paper presents examples of equations of non-Newtonian fluid dynamics (the Jeffreys system describing movement of the Earth's crust, the model of motion of weak aqueous solutions of polymers, a system with memory) for which the aforementioned construction is used to prove the existence of attractors in both the autonomous and the non-autonomous cases. At the beginning of the paper there is also a brief exposition of the results of Ladyzhenskaya on the existence of attractors of the two-dimensional Navier-Stokes system and the result of Vishik and Chepyzhov for the case of attractors of the three-dimensional Navier-Stokes system. Bibliography: 34 titles.

  17. Vortex ring formation at the open end of a shock tube: A particle image velocimetry study

    NASA Astrophysics Data System (ADS)

    Arakeri, J. H.; Das, D.; Krothapalli, A.; Lourenco, L.

    2004-04-01

    The vortex ring generated subsequent to the diffraction of a shock wave from the open end of a shock tube is studied using particle image velocimetry. We examine the early evolution of the compressible vortex ring for three-exit shock Mach numbers, 1.1, 1.2, and 1.3. For the three cases studied, the ring formation is complete at about tUb/D=2, where t is time, Ub is fluid velocity behind shock as it exits the tube and D is tube diameter. Unlike in the case of piston generated incompressible vortex rings where the piston velocity variation with time is usually trapezoidal, in the shock-generated vortex ring case the exit fluid velocity doubles from its initial value Ub before it slowly decays to zero. At the end of the ring formation, its translation speed is observed to be about 0.7 Ub. During initial formation and propagation, a jet-like flow exists behind the vortex ring. The vortex ring detachment from the tailing jet, commonly referred to as pinch-off, is briefly discussed.

  18. Particle creation and non-equilibrium thermodynamical prescription of dark fluids for universe bounded by an event horizon

    NASA Astrophysics Data System (ADS)

    Saha, Subhajit; Biswas, Atreyee; Chakraborty, Subenoy

    2015-03-01

    In the present work, flat FRW model of the universe is considered to be an isolated open thermodynamical system where non-equilibrium prescription has been studied using the mechanism of particle creation. In the perspective of recent observational evidences, the matter distribution in the universe is assumed to be dominated by dark matter and dark energy. The dark matter is chosen as dust while for dark energy, the following choices are considered: (i) Perfect fluid with constant equation of state and (ii) Holographic dark energy. In both the cases, the validity of generalized second law of thermodynamics (GSLT) which states that the total entropy of the fluid as well as that of the horizon should not decrease with the evolution of the universe, has been examined graphically for universe bounded by the event horizon. It is found that GSLT holds in both the cases with some restrictions on the interacting coupling parameter.

  19. Second trimester amniotic fluid uric acid, potassium, and cysteine to methionine ratio levels as possible signs of early preeclampsia: A case report.

    PubMed

    Fotiou, Maria; Michaelidou, Alexandra-Maria; Masoura, Sophia; Menexes, Georgios; Koulourida, Vasiliki; Biliaderis, Costas G; Tarlatzis, Basil C; Athanasiadis, Apostolos P

    2016-12-01

    The precise etiopathogenesis of preeclampsia (PE) still remains enigmatic. In recent published work, there is a scientific trend aiming to unveil early biomarkers of PE based on amniotic fluid compositional changes before the development of clinical symptoms. We describe a case of an apparently clinically healthy woman, whose amniotic fluid, retrieved after amniocentesis at 22 2/7 gestational week, had elevated uric acid and potassium concentration, as well as cysteine to methionine ratio. At the time of amniocentesis, conventional clinical signs of PE were absent. The woman developed severe PE and intrauterine growth restriction, at the 28 0/7 week of gestation. Although the limitation of such studies lies in the fact that amniocentesis is an invasive procedure, and thus employed only under specific indications, our scientific observations might be useful for future research towards unraveling the causes of PE. Copyright © 2016. Published by Elsevier B.V.

  20. Asymptotic stability of shear-flow solutions to incompressible viscous free boundary problems with and without surface tension

    NASA Astrophysics Data System (ADS)

    Tice, Ian

    2018-04-01

    This paper concerns the dynamics of a layer of incompressible viscous fluid lying above a rigid plane and with an upper boundary given by a free surface. The fluid is subject to a constant external force with a horizontal component, which arises in modeling the motion of such a fluid down an inclined plane, after a coordinate change. We consider the problem both with and without surface tension for horizontally periodic flows. This problem gives rise to shear-flow equilibrium solutions, and the main thrust of this paper is to study the asymptotic stability of the equilibria in certain parameter regimes. We prove that there exists a parameter regime in which sufficiently small perturbations of the equilibrium at time t=0 give rise to global-in-time solutions that return to equilibrium exponentially in the case with surface tension and almost exponentially in the case without surface tension. We also establish a vanishing surface tension limit, which connects the solutions with and without surface tension.

  1. On the Rigid-Lid Approximation for Two Shallow Layers of Immiscible Fluids with Small Density Contrast

    NASA Astrophysics Data System (ADS)

    Duchêne, Vincent

    2014-08-01

    The rigid-lid approximation is a commonly used simplification in the study of density-stratified fluids in oceanography. Roughly speaking, one assumes that the displacements of the surface are negligible compared with interface displacements. In this paper, we offer a rigorous justification of this approximation in the case of two shallow layers of immiscible fluids with constant and quasi-equal mass density. More precisely, we control the difference between the solutions of the Cauchy problem predicted by the shallow-water (Saint-Venant) system in the rigid-lid and free-surface configuration. We show that in the limit of a small density contrast, the flow may be accurately described as the superposition of a baroclinic (or slow) mode, which is well predicted by the rigid-lid approximation, and a barotropic (or fast) mode, whose initial smallness persists for large time. We also describe explicitly the first-order behavior of the deformation of the surface and discuss the case of a nonsmall initial barotropic mode.

  2. Activity and immunodetection of lysozyme in earthworm Dendrobaena veneta (Annelida).

    PubMed

    Fiołka, Marta J; Zagaja, Mirosław P; Hułas-Stasiak, Monika; Wielbo, Jerzy

    2012-01-01

    In the present study, lysozyme-like activity against Micrococcus luteus was detected in the coelomic fluid, the extract from coelomocytes, intestine and in the homogenates from cocoons of Dendrobaena veneta. Four hours after immunization with Escherichia coli, the lysozyme activity in the coelomic fluid increased about three times and in the extract of coelomocytes - four times, in comparison to the control. In three cases: of the coelomic fluid, the homogenates from cocoons and the extract from coelomocytes, the antibody against HEWL (hen egg white lysozyme) recognized only one protein with a molecular mass of about 14.4 kDa. In the coelomic fluid, apart from the protein with molecular mass of 14.4 kDa the antibody directed against human lysozyme recognized an additional protein of 22 kDa. Using the bioautography technique after electrophoretic resolution of native proteins in acidic polyacrylamide gels, two lytic zones of M. luteus were observed in the case of the coelomic fluid and three after the analysis of the extract of coelomocytes and the egg homogenates. The results indicated the existence of several forms of lysozyme with a different electric charge in the analyzed D. veneta samples. The highest lysozyme activity in the intestine of D. veneta was observed in the midgut. The antibody directed against human lysozyme indicated a strong positive signal in epidermal and midgut cells of earthworm. Copyright © 2011 Elsevier Inc. All rights reserved.

  3. Upper airway compromise by extravasated fluid: a rare complication after arthroscopic repair of atrophic cuff tear.

    PubMed

    Venkat, Gorthi; Moon, Young Lae; Na, Woong Chae; So, Keum Young

    2009-10-01

    During arthroscopic procedures, leakage of irrigation fluid into surrounding tissue planes is a frequently noticed phenomenon usually clinically asymptomatic and resolving within 12 hours postoperatively. Although rare, this fluid may produce life-threatening complications such as airway compromise. This article describes a case of upper airway obstruction in a 60-year-old man undergoing arthroscopic repair for an atrophic rotator cuff tear. The patient presented with a 6-month history of pain and weakness in the left shoulder. Magnetic resonance imaging studies revealed a massive rotator cuff tear with significant retraction and fatty degeneration of cuff musculature. Perioperatively, all vital cardiorespiratory parameters were within normal limits. Postoperatively, immediately on extubation, he was dyspneic, and examination revealed a diffuse swelling extending from the left shoulder up to the neck and face. He was reintubated and sent to the recovery room, where he recovered 12 hours later. This article highlights the possibility of respiratory compromise due to the extravasation of irrigation fluid into the neck and chest during arthroscopic repair of massive and atrophied cuff tears, even with shorter surgical time as is this case. The widened suprascapular space will offer less resistance to the spread of fluid into the neck and chest from the shoulder. We advocate monitoring the patient continuously to prevent this serious complication from becoming life-threatening.

  4. New insights from one case of female ejaculation.

    PubMed

    Rubio-Casillas, Alberto; Jannini, Emmanuele A

    2011-12-01

    Although there are historical records showing its existence for over 2,000 years, the so-called female ejaculation is still a controversial phenomenon. A shared paradigm has been created that includes any fluid expulsion during sexual activities with the name of "female ejaculation." To demonstrate that the "real" female ejaculation and the "squirting or gushing" are two different phenomena. Biochemical studies on female fluids expelled during orgasm. In this case report, we provided new biochemical evidences demonstrating that the clear and abundant fluid that is ejected in gushes (squirting) is different from the real female ejaculation. While the first has the features of diluted urines (density: 1,001.67 ± 2.89; urea: 417.0 ± 42.88 mg/dL; creatinine: 21.37 ± 4.16 mg/dL; uric acid: 10.37 ± 1.48 mg/dL), the second is biochemically comparable to some components of male semen (prostate-specific antigen: 3.99 ± 0.60 × 103 ng/mL). Female ejaculation and squirting/gushing are two different phenomena. The organs and the mechanisms that produce them are bona fide different. The real female ejaculation is the release of a very scanty, thick, and whitish fluid from the female prostate, while the squirting is the expulsion of a diluted fluid from the urinary bladder. © 2011 International Society for Sexual Medicine.

  5. Instability and dynamics of volatile thin films

    NASA Astrophysics Data System (ADS)

    Ji, Hangjie; Witelski, Thomas P.

    2018-02-01

    Volatile viscous fluids on partially wetting solid substrates can exhibit interesting interfacial instabilities and pattern formation. We study the dynamics of vapor condensation and fluid evaporation governed by a one-sided model in a low-Reynolds-number lubrication approximation incorporating surface tension, intermolecular effects, and evaporative fluxes. Parameter ranges for evaporation-dominated and condensation-dominated regimes and a critical case are identified. Interfacial instabilities driven by the competition between the disjoining pressure and evaporative effects are studied via linear stability analysis. Transient pattern formation in nearly flat evolving films in the critical case is investigated. In the weak evaporation limit unstable modes of finite-amplitude nonuniform steady states lead to rich droplet dynamics, including flattening, symmetry breaking, and droplet merging. Numerical simulations show that long-time behaviors leading to evaporation or condensation are sensitive to transitions between filmwise and dropwise dynamics.

  6. Detection of acute lymphoblastic leukemia involvement in pleural fluid in an adult patient with ataxia telangiectasia by flow cytometry method.

    PubMed

    Keklik, Muzaffer; Koker, M Yavuz; Sivgin, Serdar; Camlica, Demet; Pala, Cigdem; Cetin, Mustafa; Kaynar, Leylagul; Unal, Ali; Eser, Bulent

    2014-09-01

    Ataxia-telangiectasia (AT) is a rare multisystem, neurodegenerative genetic disorder. Patients should be closely monitored due to risk of malignancy development. Due to its wide clinical heterogeneity, it often leads physicians to an inaccurate or missed diagnosis, and insight into this rare disease is important. Pediatric patients may develop lymphomas and acute lymphoblastic leukemia (ALL). However, in adults, there are limited numbers of reports regarding association of AT and ALL. Rarely, ALL cases may present with pleural fluid involvement. In our study, we presented an adult case with AT, in which ALL involvement was detected in pleural fluid by flow cytometry (FC). A 20-years old male presented to emergency department with fever, shortness of breath and cough, as he had been followed with a diagnosis of AT. The following findings were detected in laboratory tests: Hb, 11.5 g/L; WBC, 36 × 10(9)/L; Plt: 140 × 10(9)/L. Blastic cells were observed in peripheral blood smear. On chest radiography, pleural fluid appearance was observed. On thorax CT, pleural fluid was detected in both hemithorax. Cytoplasmic CD3(+) and superficial CD3 (+), CD45 (+), CD5 (+), CD7 (+) and CD38 (+) was found in the flow cytometric evaluation of peripheral blood. Superficial CD3 (+), CD2 (+), CD5 (+) and CD7 (+) were found in flow cytometric evaluation of pleural fluid. These findings were considered as consistent with pleural involvement of T-ALL. FC is a potentially useful diagnostic tool for clinical practice and it is a convenience method which has an important role in detection of ALL in patients with pleural fluid.

  7. Management of Gastric Obstruction Caused by Adjustable Gastric Band.

    PubMed

    Czeiger, David; Abu-Swis, Shadi; Shaked, Gad; Ovnat, Amnon; Sebbag, Gilbert

    2016-12-01

    Optimal adjustment of the filling volume of laparoscopic adjustable gastric banding is challenging and commonly performed empirically. Patients with band over-inflation and gastric obstruction arrive at the emergency department complaining of recurrent vomiting. In cases of gastric obstruction, intra-band pressure measurement may assist in determining the amount of fluid that should be removed from the band; however, our investigations have determined that intra-band pressure assessment need not play a role in the treatment of gastric band obstruction. In patients coming to the emergency department with gastric band obstruction, we measured intra-band pressure at arrival and following stepped removal of fluid, comparing the initial pressure with post-deflation pressure and measuring the volume of fluid removed. Forty-eight patients participated in the study. Forty-five patients had a low-pressure/high-volume band. Their mean baseline pressure was 54.6 ± 22.3 mmHg. The mean volume of fluid removed from the band was 1.3 ± 0.8 ml. The mean post-deflation pressure was 22.5 ± 16.3 mmHg. Nearly 30 % of patients required as little as 0.5 ml of fluid removal, and 60 % of them were free of symptoms with removal of 1 ml. Our results indicate that intra-band pressure measurement is of little value for determining the amount of fluid that should be removed for treatment of band obstruction. We suggest the removal of fluid in volumes of 0.5 ml until symptoms are relieved. Only in complicated cases, such as in patients having recurrent obstructions, should additional modalities be employed for further management guidance.

  8. Porous media deformation due to fluid flow: From hydrofracture formation to seismic liquefaction, a numerical and experimental study

    NASA Astrophysics Data System (ADS)

    Toussaint, R.; Turkaya, S.; Eriksen, F.; Clément, C.; Sanchez-Colina, G.; Maloy, K. J.; Flekkoy, E.; Aharonov, E.; Lengliné, O.; Daniel, G.; Altshuler, E.; Batista-Leyva, A.; Niebling, M.

    2016-12-01

    We present here the deformation of porous media in two different situations: 1. The formation of channels and fracture during pressurization of pore fluids, as happens during eruptions or injection of fluids and gas into soils and rocks. 2. The liquefaction of soils at different degrees of saturations during Earthquakes. The formation of channels during hydrofracture and pneumatic fractures is studied in laboratory experiments and in numerical models. The experiments are done on different types of porous media in Hele-Shaw cells, where fluid is injected at controlled overpressures, and various boundary conditions are used. Using fast cameras, we determine the strain and velocity fields from the images. We also record the characteristics of micro-seismic emissions during the process, and link this seismic record features and the direct image of the displacement responsible for the seismic sources in the medium. We also carry out numerical simulations, using coupled fluid/solid hydrid models that capture solid stress, pore pressure, solid and fluid elasticity - a full poro-elasto-plastic model using granular representation of the solid and a continuous one for the fluid.Next, Soil liquefaction is a significant natural hazard associated with earthquakes. Some of its devastating effects include tilting and sinking of buildings and bridges, and destruction of pipelines. Conventional geotechnical engineering assumes liquefaction occurs via elevated pore pressure. This assumption guides construction for seismically hazardous locations, yet evidence suggests that liquefaction strikes also under currently unpredicted conditions. We show, using theory, simulations and experiments, another mechanism for liquefaction in saturated soils, without high pore fluid pressure and without special soils, whereby liquefaction is controlled by buoyancy forces. This new mechanism enlarges the window of conditions under which liquefaction is predicted to occur, and may explain previously not understood cases such as liquefaction in well-compacted soils, under drained conditions, repeated liquefaction cases, far-field liquefaction and the basics of sinking in quicksand. These results may greatly impact hazard assessment and mitigation in seismically active areas.

  9. Beryllium chemical speciation in elemental human biological fluids.

    PubMed

    Sutton, Mark; Burastero, Stephen R

    2003-09-01

    The understanding of beryllium chemistry in human body fluids is important for understanding the prevention and treatment of chronic beryllium disease. Thermodynamic modeling has traditionally been used to study environmental contaminant migration and rarely in the examination of metal (particularly beryllium) toxicology. In this work, a chemical thermodynamic speciation code (MINTEQA2) has been used to model and understand the chemistry of beryllium in simulated human biological fluids such as intracellular, interstitial, and plasma fluids, a number of airway surface fluids for patients with lung conditions, saliva, sweat, urine, bile, gastric juice, and pancreatic fluid. The results show that predicted beryllium solubility and speciation vary markedly between each simulated biological fluid. Formation of beryllium hydroxide and/or phosphate was observed in most of the modeled fluids, and results support the postulation that beryllium absorption in the gastrointestinal tract may be limited by the formation of beryllium phosphate solids. It is also postulated that beryllium is potentially 13% less soluble in the airway surface fluid of a patient with asthma when compared to a "normal" case. The results of this work, supported by experimental validation, can aid in the understanding of beryllium toxicology. Our results can potentially be applied to assessing the feasibility of biological monitoring or chelation treatment of beryllium body burden.

  10. Space station integrated propulsion and fluid systems study. Space station program fluid management systems databook

    NASA Technical Reports Server (NTRS)

    Bicknell, B.; Wilson, S.; Dennis, M.; Lydon, M.

    1988-01-01

    Commonality and integration of propulsion and fluid systems associated with the Space Station elements are being evaluated. The Space Station elements consist of the core station, which includes habitation and laboratory modules, nodes, airlocks, and trusswork; and associated vehicles, platforms, experiments, and payloads. The program is being performed as two discrete tasks. Task 1 investigated the components of the Space Station architecture to determine the feasibility and practicality of commonality and integration among the various propulsion elements. This task was completed. Task 2 is examining integration and commonality among fluid systems which were identified by the Phase B Space Station contractors as being part of the initial operating capability (IOC) and growth Space Station architectures. Requirements and descriptions for reference fluid systems were compiled from Space Station documentation and other sources. The fluid systems being examined are: an experiment gas supply system, an oxygen/hydrogen supply system, an integrated water system, the integrated nitrogen system, and the integrated waste fluids system. Definitions and descriptions of alternate systems were developed, along with analyses and discussions of their benefits and detriments. This databook includes fluid systems descriptions, requirements, schematic diagrams, component lists, and discussions of the fluid systems. In addition, cost comparison are used in some cases to determine the optimum system for a specific task.

  11. REE controls in ultramafic hosted MOR hydrothermal systems: An experimental study at elevated temperature and pressure

    NASA Astrophysics Data System (ADS)

    Allen, Douglas E.; Seyfried, W. E.

    2005-02-01

    A hydrothermal experiment involving peridotite and a coexisting aqueous fluid was conducted to assess the role of dissolved Cl - and redox on REE mobility at 400°C, 500 bars. Data show that the onset of reducing conditions enhances the stability of soluble Eu +2 species. Moreover, Eu +2 forms strong aqueous complexes with dissolved Cl - at virtually all redox conditions. Thus, high Cl - concentrations and reducing conditions can combine to reinforce Eu mobility. Except for La, trivalent REE are not greatly affected by fluid speciation under the chemical and physical condition considered, suggesting control by secondary mineral-fluid partitioning. LREE enrichment and positive Eu anomalies observed in fluids from the experiment are remarkably similar to patterns of REE mobility in vent fluids issuing from basalt- and peridotite-hosted hydrothermal systems. This suggests that the chondrite normalized REE patterns are influenced greatly by fluid speciation effects and secondary mineral formation processes. Accordingly, caution must be exercised when using REE in hydrothermal vent fluids to infer REE sources in subseafloor reaction zones from which the fluids are derived. Although vent fluid patterns having LREE enrichment and positive Eu anomalies are typically interpreted to suggest plagioclase recrystallization reactions, this need not always be the case.

  12. From Cholera to Burns: A Role for Oral Rehydration Therapy

    PubMed Central

    Green, W.B.; Asuku, M.E.; Feldman, M.; Makam, R.; Noppenberger, D.; Price, L.A.; Prosciak, M.; van Loon, I.N.

    2011-01-01

    According to the practice guidelines of the American Burn Association on burn shock resuscitation, intravenous (IV) fluid therapy is the standard of care for the replacement of fluid and electrolyte losses in burn injury of ≥20% of the total body surface area. However, in mass burn casualties, IV fluid resuscitation may be delayed or unavailable. Oral rehydration therapy (ORT), which has been shown to be highly effective in the treatment of dehydration in epidemics of cholera, could be an alternate way to replace fluid losses in burns. A prospective case series of three patients was carried out as an initial step to establish whether oral Ceralyte®90 could replace fluid losses requiring IV fluid therapy in thermal injury. The requirement of the continuing IV fluid therapy was reduced by an average of 58% in the first 24 hours after the injury (range 37-78%). ORT may be a feasible alternative to IV fluid therapy in the resuscitation of burns. It could also potentially save many lives in mass casualty situations or in resource-poor settings where IV fluid therapy is not immediately available. Further studies are needed to assess the efficacy of this treatment and to determine whether the present formulations of ORT for cholera need modification. PMID:22283039

  13. Possibilities of three-component geoacoustic logging at hydrocarbon deposits.

    NASA Astrophysics Data System (ADS)

    Trojanov, Alexandr; Astrakhantsev, Yurie; Nachapkin, Nikolay; Beloglasova, Nadejda; Bajenova, Evgenia; Vdovin, Alexey

    2013-04-01

    The geophysical method of oil-gas borehole investigation devised at the Institute of geophysics UB of RAS studies characteristics of geoacoustic emission (GAE) over the frequency range of 0.1÷5 kHz which displays peculiarities of fluid-gas dynamic processes in a volume of geological environment. More over: 1. The second displacement derivative (acceleration) of borehole walls' vibrations is recorded. 2. The three-component system of orthogonal transducers-accelerometers in a protecting casing of a borehole instrument with the diameter of 40-42 mm enabling to divide geoenvironment microvibrations into three directions is applied. 3. Frequency composition of recorded geoacoustic signals is analyzed. 4. Values of measured and calculated parameters representing distribution of signal amplitudes according to three components at four frequency bands are evaluated. Three-component geoacoustic logging at hydrocarbon deposits solves the following problems: · Estimation of fluid saturation character at a qualitative level; · Detection of fluid flow outside and inside the casing string with division into fluid types; · Detection of fluid flow position in chambers of a cement ring with division into fluid types; · Detection of non-sealed points of borehole equipment; · Location of gas-water, gas-oil ad water-oil contacts; · Study of inflow section in a perforated interval of casing string which determines the boundaries of efficient intervals; · Detection of sections with high absorption of drilling fluid in an open shaft; · Test for leaks of the column (together with thermometry); · Detection of intervals of fluid movement in horizontal direction outside a casing string within seams (it is impossible to determine them by other methods); · Detection of industrial deposits; · Revelation of water-flooded intervals of a hydrocarbon deposit. Transducers-accelerometers with relative coefficient of transverse conversion not more than 6% allow confident division of signals into three directions. Transverse sensitivity of a transducer is determined by its maximum sensitivity to oscillations in a direction perpendicular to its main axis that is parallel to the surface where it is placed. The equipment [1] has sensitivity that enables to record an acoustic response of geoenvironment to deformations in the order of 10-8 - 10-11 m. Geoacoustic signals in sedimentary rocks are recorded by three orthogonal transducers-accelerometers of PVT type (piezoelectric vibromeasuring transducer). Transducers with coefficients of conversion not less than 6-10 µV*s2/mm are installed into a borehole instrument. Amplitude level of signals at different frequency bands is presented in units of recorded acceleration mm/s2. Small amplitude of geoenvironment microvibrations is an additional optimum condition to divide signals from three directions. Thus, signals from three directions are fixed at preset depth in a borehole which makes it possible to compare their amplitude at different frequency bands. References: 1. Yu. G. Astrakhantsev and A. K. Troyanov, RF Patent No. 2 445 653, 2012.

  14. Relationships of models of the inner magnetosphere to the Rice Convection Model

    NASA Astrophysics Data System (ADS)

    Heinemann, M.; Wolf, R. A.

    2001-08-01

    Ideal magnetohydrodynamics is known to be inaccurate for the Earth's inner magnetosphere, where transport by gradient-curvature drift is nonnegligible compared to E×B drift. Most theoretical treatments of the inner plasma sheet and ring current, including the Rice Convection Model (RCM), treat the inner magnetospheric plasma in terms of guiding center drifts. The RCM assumes that the distribution function is isotropic, but particles with different energy invariants are treated as separate guiding center fluids. However, Peymirat and Fontaine [1994] developed a two-fluid picture of the inner magnetosphere, which utilizes modified forms of the conventional fluid equations, not guiding center drift equations. Heinemann [1999] argued theoretically that for inner magnetospheric conditions the fluid energy equation should include a heat flux term, which, in the case of Maxwellian plasma, was derived by Braginskii [1965]. We have now reconciled the Heinemann [1999] fluid approach with the RCM. The fluid equations, including the Braginskii heat flux, can be derived by taking appropriate moments of the RCM equations for the case of the Maxwellian distribution. The physical difference between the RCM formalism and the Heinemann [1999] fluid approach is that the RCM pretends that particles suffer elastic collisions that maintain the isotropy of the distribution function but do not change particle energies. The Heinemann [1999] fluid treatment makes a different physical approximation, namely that the collisions maintain local thermal equilibrium among the ions and separately among the electrons. For some simple cases, numerical results are presented that illustrate the differences in the predictions of the two formalisms, along with those of MHD, guiding center theory, and Peymirat and Fontaine [1994].

  15. Evaluation of CO 2 -Fluid-Rock Interaction in Enhanced Geothermal Systems: Field-Scale Geochemical Simulations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pan, Feng; McPherson, Brian J.; Kaszuba, John

    Recent studies suggest that using supercritical CO 2 (scCO 2 ) instead of water as a heat transmission fluid in Enhanced Geothermal Systems (EGS) may improve energy extraction. While CO 2 -fluid-rock interactions at “typical” temperatures and pressures of subsurface reservoirs are fairly well known, such understanding for the elevated conditions of EGS is relatively unresolved. Geochemical impacts of CO 2 as a working fluid (“CO 2 -EGS”) compared to those for water as a working fluid (H 2 O-EGS) are needed. The primary objectives of this study are (1) constraining geochemical processes associated with CO 2 -fluid-rock interactions undermore » the high pressures and temperatures of a typical CO 2 -EGS site and (2) comparing geochemical impacts of CO 2 -EGS to geochemical impacts of H 2 O-EGS. The St. John’s Dome CO 2 -EGS research site in Arizona was adopted as a case study. A 3D model of the site was developed. Net heat extraction and mass flow production rates for CO 2 -EGS were larger compared to H 2 O-EGS, suggesting that using scCO 2 as a working fluid may enhance EGS heat extraction. More aqueous CO 2 accumulates within upper- and lower-lying layers than in the injection/production layers, reducing pH values and leading to increased dissolution and precipitation of minerals in those upper and lower layers. Dissolution of oligoclase for water as a working fluid shows smaller magnitude in rates and different distributions in profile than those for scCO 2 as a working fluid. It indicates that geochemical processes of scCO 2 -rock interaction have significant effects on mineral dissolution and precipitation in magnitudes and distributions.« less

  16. Evaluation of CO 2 -Fluid-Rock Interaction in Enhanced Geothermal Systems: Field-Scale Geochemical Simulations

    DOE PAGES

    Pan, Feng; McPherson, Brian J.; Kaszuba, John

    2017-01-01

    Recent studies suggest that using supercritical CO 2 (scCO 2 ) instead of water as a heat transmission fluid in Enhanced Geothermal Systems (EGS) may improve energy extraction. While CO 2 -fluid-rock interactions at “typical” temperatures and pressures of subsurface reservoirs are fairly well known, such understanding for the elevated conditions of EGS is relatively unresolved. Geochemical impacts of CO 2 as a working fluid (“CO 2 -EGS”) compared to those for water as a working fluid (H 2 O-EGS) are needed. The primary objectives of this study are (1) constraining geochemical processes associated with CO 2 -fluid-rock interactions undermore » the high pressures and temperatures of a typical CO 2 -EGS site and (2) comparing geochemical impacts of CO 2 -EGS to geochemical impacts of H 2 O-EGS. The St. John’s Dome CO 2 -EGS research site in Arizona was adopted as a case study. A 3D model of the site was developed. Net heat extraction and mass flow production rates for CO 2 -EGS were larger compared to H 2 O-EGS, suggesting that using scCO 2 as a working fluid may enhance EGS heat extraction. More aqueous CO 2 accumulates within upper- and lower-lying layers than in the injection/production layers, reducing pH values and leading to increased dissolution and precipitation of minerals in those upper and lower layers. Dissolution of oligoclase for water as a working fluid shows smaller magnitude in rates and different distributions in profile than those for scCO 2 as a working fluid. It indicates that geochemical processes of scCO 2 -rock interaction have significant effects on mineral dissolution and precipitation in magnitudes and distributions.« less

  17. To Study the Incidence, Predictive Factors and Clinical Outcome of Spontaneous Bacterial Peritonitis in Patients of Cirrhosis with Ascites.

    PubMed

    Paul, Kavita; Kaur, Jasmine; Kazal, Harbans Lal

    2015-07-01

    To study the prevalence and predictive factors of spontaneous bacterial peritonitis (SBP) in patients of cirrhosis with ascites and to study the clinical characteristics and prognosis of patients with SBP. The present study was conducted on 122 cases admitted in Department of Medicine, through emergency, in Guru Gobind Singh Medical College and Hospital, Faridkot, Punjab, India. Cases of cirrhosis (irrespective of aetiology) with ascites between the ages of 18-75 years were included in this study. Ascitic fluid of every patient was aspirated under all aseptic measures, before initiation of antibiotic therapy and was sent for biochemical analysis, culture and cytological analysis. Mean age of patients enrolled was 50.30± 10.98 years. 85% were male and 15% were female. Alcohol (73.8%) was the leading cause of cirrhosis followed by HCV (37.7%) and HBV (4.9%). Of the 122 patients studied, 27 (20.4%) patients were diagnosed as having SBP and its variants. Monomicrobial Bacterascites (BA) was present in 5 patients and Culture Negative Neutrocytic Ascites (CNNA) was present in 22 patients. Escherichia coli were the most common isolated organism followed by Klebsiella. The various factors that predispose to development of SBP include low ascitic fluid protein concentration, a high level of serum bilirubin, deranged serum creatinine, high Child-Pugh score and high MELD score. Ascitic fluid analysis remains the single most important test for identifying and assessing a course of SBP. Bedside inoculation of 10-20ml of ascitic fluid into culture bottle at patient bedside will yield better results. Early diagnosis and treatment will reduce the mortality rate in these patients.

  18. Electrodiagnostic and clinical aspects of Guillain-Barré syndrome: an analysis of 142 cases.

    PubMed

    Gupta, Deepak; Deepak, Gupta; Nair, Muraleedharan; Muraleedharan, Nair; Baheti, Neeraj N; Sarma, P Sankara; Sarma, Sankara P; Kuruvilla, Abraham; Abraham, Kuruvilla

    2008-12-01

    The incidence of Guillain-Barré syndrome (GBS) and its subtypes varies throughout the world. We present a retrospective analysis of 142 GBS cases, treated at our center, aimed at classifying GBS electrophysiologically, to study the sequential electrophysiological changes in cases with acute inflammatory demyelinating polyradiculoneuropathy (AIDP), and to look for any clinical and cerebrospinal fluid parameters that can also help in distinguishing the subtypes. One hundred twenty-one (85.2%) cases had AIDP, 15 (10.6%) had acute motor axonal neuropathy, and 6 (4.2%) were unclassifiable. Motor conduction blocks and temporal dispersion could be observed from days 3 and 5 onward, respectively. Progression of motor conduction slowing in AIDP was most impressive in the median nerves. Varying affection of deep tendon reflexes, cranial nerves, and cerebrospinal fluid albuminocytological dissociation can also help make a distinction between AIDP and acute motor axonal neuropathy. Sural sparing, a marker of demyelinating neuropathy, is more commonly seen in later than in early stages of AIDP.

  19. Bio-convection on the nonlinear radiative flow of a Carreau fluid over a moving wedge with suction or injection

    NASA Astrophysics Data System (ADS)

    Raju, C. S. K.; Ibrahim, S. M.; Anuradha, S.; Priyadharshini, P.

    2016-11-01

    In modern days, the mass transfer rate is challenging to the scientists due to its noticeable significance for industrial as well as engineering applications; owing to this we attempt to study the cross-diffusion effects on the magnetohydrodynamic nonlinear radiative Carreau fluid over a wedge filled with gyro tactic microorganisms. Numerical results are presented graphically as well as in tabular form with the aid of the Runge-Kutta and Newton methods. The effects of pertinent parameters on velocity, temperature, concentration and density of motile organism distributions are presented and discussed for two cases (suction and injection flows). For real-life application we also calculated the local Nusselt and Sherwood numbers. It is observed that thermal and concentration profiles are not uniform in the suction and injection flow cases. It is found that the heat and mass transport phenomenon is high in the injection case, while heat and mass transfer rates are high in the suction flow case.

  20. Health effects of oil mists: a brief review.

    PubMed

    Mackerer, C R

    1989-05-01

    Metal cutting/grinding fluids are of three basic types: straight oil (insoluble), oil-in-water emulsions (soluble) and synthetic/semisynthetic. All contain a variety of additives to improve performance. Human exposure occurs primarily by direct skin contact with the liquid or by skin and respiratory contact after fluid misting. Dermatitis caused by primary or direct skin irritation is the most prevalent health effect of exposure to cutting fluids. Occasionally allergic dermatitis is seen which is related to the development of sensitization to one or more of the additive components. Recent studies indicate that long-term exposure to cutting fluids does not result in increased incidences of lung cancer, urinary bladder cancer, gastrointestinal cancer, or death from non-malignant respiratory diseases. Long-term exposure to certain cutting fluids, however, is believed to have resulted in certain types of skin cancer, especially scrotal cancer. It is likely that these carcinogenic responses were caused by contact with polycyclic aromatic compounds (PCA) of 3-7 rings. Modern base oils which are severely refined have very low levels of PCA, are not carcinogenic in animal bioassays, and are unlikely to be carcinogenic in man. This is not necessarily true for re-refined oils which may contain significant levels of PCA and polychlorinated biphenyls derived from comingling used cutting oils with used engine oils and transformer oils. Cutting oils, themselves, generally do not accumulate significant levels of carcinogenic PCA during use. Additives, in theory, can cause a variety of health effects either directly or through the generation of reaction products such as nitrosamines. In actual use, adverse health effects appear to be limited to occasional instances of allergic contact dermatitis. Nitrosamines are extremely carcinogenic in test animals; although no human cancer cases directly attributable to nitrosamine contamination have been observed, nitrosating agents and amines should not be combined in cutting fluid formulations. It is difficult to anticipate or predict the potential toxicity of a particular cutting fluid formulation because of the presence of variable amounts of proprietary additives which, themselves, are often complex reaction mixtures. Thus, each additive and final formulation must be evaluated on a case by case basis to appropriately assess potential health hazards.

  1. Congenital Toxoplasmosis in Tunisia: Prenatal and Neonatal Diagnosis and Postnatal Follow-up of 35 Cases.

    PubMed

    Boudaouara, Yosr; Aoun, Karim; Maatoug, Rania; Souissi, Olfa; Bouratbine, Aïda; Abdallah, Rym Ben

    2018-06-01

    Congenital toxoplasmosis (CT) results from transplacental passage of Toxoplasma gondii to the fetus during acute maternal infection. Our study aims to report clinical and biological patterns of 35 cases of CT diagnosed at the department of the Parasitology of the Pasteur Institute of Tunis and to access the performance of prenatal and early postnatal diagnosis techniques. Serological screening of maternal infection was performed by Immunoglobulin (Ig) M and IgG detection and IgG avidity determination. Prenatal diagnosis was based on both Toxoplasma DNA detection in the amniotic fluid and monthly ultrasound examinations. polymerase chain reaction analysis on amniotic fluid, performed only in 15 cases, detected Toxoplasma 's DNA in five cases (33.3%). Ultrasound examination did not reveal any morphological abnormalities. Thirty newborns had serological criteria of Toxoplasma infection. Congenital toxoplasmosis diagnosis was confirmed in 23 cases (76.6%) by immunoblot. Among the 35 born-infants, five (14.3%) were symptomatic: three had chorioretinitis at the first clinical ocular examination, one had neurological symptoms (seizures) with positive parasite DNA in cerebral spinal fluid, and one had both ophthalmological and neurological damages- chorioretinitis and intracranial calcifications in the computed tomography scan. Thirty-four of 35 infected children were treated with pyrimethamine-sulfadiazine combination. Four (11.7%) of the treated infants showed abnormal hematological values because of the treatment side effect. Serological rebound was observed in seven infants. A screening program and a diagnostic algorithm in pregnant women should be implemented in Tunisia to improve the follow-up of seronegative ones and to prevent CT cases.

  2. Mechanical Expansion of Steel Tubing as a Solution to Leaky Wellbores

    PubMed Central

    Radonjic, Mileva; Kupresan, Darko

    2014-01-01

    Wellbore cement, a procedural component of wellbore completion operations, primarily provides zonal isolation and mechanical support of the metal pipe (casing), and protects metal components from corrosive fluids. These are essential for uncompromised wellbore integrity. Cements can undergo multiple forms of failure, such as debonding at the cement/rock and cement/metal interfaces, fracturing, and defects within the cement matrix. Failures and defects within the cement will ultimately lead to fluid migration, resulting in inter-zonal fluid migration and premature well abandonment. Currently, there are over 1.8 million operating wells worldwide and over one third of these wells have leak related problems defined as Sustained Casing Pressure (SCP)1. The focus of this research was to develop an experimental setup at bench-scale to explore the effect of mechanical manipulation of wellbore casing-cement composite samples as a potential technology for the remediation of gas leaks. The experimental methodology utilized in this study enabled formation of an impermeable seal at the pipe/cement interface in a simulated wellbore system. Successful nitrogen gas flow-through measurements demonstrated that an existing microannulus was sealed at laboratory experimental conditions and fluid flow prevented by mechanical manipulation of the metal/cement composite sample. Furthermore, this methodology can be applied not only for the remediation of leaky wellbores, but also in plugging and abandonment procedures as well as wellbore completions technology, and potentially preventing negative impacts of wellbores on subsurface and surface environments. PMID:25490436

  3. Mechanical expansion of steel tubing as a solution to leaky wellbores.

    PubMed

    Radonjic, Mileva; Kupresan, Darko

    2014-11-20

    Wellbore cement, a procedural component of wellbore completion operations, primarily provides zonal isolation and mechanical support of the metal pipe (casing), and protects metal components from corrosive fluids. These are essential for uncompromised wellbore integrity. Cements can undergo multiple forms of failure, such as debonding at the cement/rock and cement/metal interfaces, fracturing, and defects within the cement matrix. Failures and defects within the cement will ultimately lead to fluid migration, resulting in inter-zonal fluid migration and premature well abandonment. Currently, there are over 1.8 million operating wells worldwide and over one third of these wells have leak related problems defined as Sustained Casing Pressure (SCP). The focus of this research was to develop an experimental setup at bench-scale to explore the effect of mechanical manipulation of wellbore casing-cement composite samples as a potential technology for the remediation of gas leaks. The experimental methodology utilized in this study enabled formation of an impermeable seal at the pipe/cement interface in a simulated wellbore system. Successful nitrogen gas flow-through measurements demonstrated that an existing microannulus was sealed at laboratory experimental conditions and fluid flow prevented by mechanical manipulation of the metal/cement composite sample. Furthermore, this methodology can be applied not only for the remediation of leaky wellbores, but also in plugging and abandonment procedures as well as wellbore completions technology, and potentially preventing negative impacts of wellbores on subsurface and surface environments.

  4. Magneto-hydrodynamics of coupled fluid-sheet interface with mass suction and blowing

    NASA Astrophysics Data System (ADS)

    Ahmad, R.

    2016-01-01

    There are large number of studies which prescribe the kinematics of the sheet and ignore the sheet's mechanics. However, the current boundary layer analysis investigates the mechanics of both the electrically conducting fluid and a permeable sheet, which makes it distinct from the other studies in the literature. One of the objectives of the current study is to (i) examine the behaviour of magnetic field effect for both the surface and the electrically conducting fluid (ii) investigate the heat and mass transfer between a permeable sheet and the surrounding electrically conducting fluid across the hydro, thermal and mass boundary layers. Self-similar solutions are obtained by considering the RK45 technique. Analytical solution is also found for the stretching sheet case. The skin friction dual solutions are presented for various types of sheet. The influence of pertinent parameters on the dimensionless velocity, shear stress, temperature, mass concentration, heat and mass transfer rates on the fluid-sheet interface is presented graphically as well as numerically. The obtained results are of potential benefit for studying the electrically conducting flow over various soft surfaces such as synthetic plastics, soft silicone sheet and soft synthetic rubber sheet. These surfaces are easily deformed by thermal fluctuations or thermal stresses.

  5. A kinetic Monte Carlo approach to study fluid transport in pore networks

    NASA Astrophysics Data System (ADS)

    Apostolopoulou, M.; Day, R.; Hull, R.; Stamatakis, M.; Striolo, A.

    2017-10-01

    The mechanism of fluid migration in porous networks continues to attract great interest. Darcy's law (phenomenological continuum theory), which is often used to describe macroscopically fluid flow through a porous material, is thought to fail in nano-channels. Transport through heterogeneous and anisotropic systems, characterized by a broad distribution of pores, occurs via a contribution of different transport mechanisms, all of which need to be accounted for. The situation is likely more complicated when immiscible fluid mixtures are present. To generalize the study of fluid transport through a porous network, we developed a stochastic kinetic Monte Carlo (KMC) model. In our lattice model, the pore network is represented as a set of connected finite volumes (voxels), and transport is simulated as a random walk of molecules, which "hop" from voxel to voxel. We simulated fluid transport along an effectively 1D pore and we compared the results to those expected by solving analytically the diffusion equation. The KMC model was then implemented to quantify the transport of methane through hydrated micropores, in which case atomistic molecular dynamic simulation results were reproduced. The model was then used to study flow through pore networks, where it was able to quantify the effect of the pore length and the effect of the network's connectivity. The results are consistent with experiments but also provide additional physical insights. Extension of the model will be useful to better understand fluid transport in shale rocks.

  6. Evaluation of stroke volume variation obtained by arterial pulse contour analysis to predict fluid responsiveness intraoperatively.

    PubMed

    Lahner, D; Kabon, B; Marschalek, C; Chiari, A; Pestel, G; Kaider, A; Fleischmann, E; Hetz, H

    2009-09-01

    Fluid management guided by oesophageal Doppler monitor has been reported to improve perioperative outcome. Stroke volume variation (SVV) is considered a reliable clinical predictor of fluid responsiveness. Consequently, the aim of the present trial was to evaluate the accuracy of SVV determined by arterial pulse contour (APCO) analysis, using the FloTrac/Vigileo system, to predict fluid responsiveness as measured by the oesophageal Doppler. Patients undergoing major abdominal surgery received intraoperative fluid management guided by oesophageal Doppler monitoring. Fluid boluses of 250 ml each were administered in case of a decrease in corrected flow time (FTc) to <350 ms. Patients were connected to a monitoring device, obtaining SVV by APCO. Haemodynamic variables were recorded before and after fluid bolus application. Fluid responsiveness was defined as an increase in stroke volume index >10%. The ability of SVV to predict fluid responsiveness was assessed by calculation of the area under the receiver operating characteristic (ROC) curve. Twenty patients received 67 fluid boluses. Fifty-two of the 67 fluid boluses administered resulted in fluid responsiveness. SVV achieved an area under the ROC curve of 0.512 [confidence interval (CI) 0.32-0.70]. A cut-off point for fluid responsiveness was found for SVV > or =8.5% (sensitivity: 77%; specificity: 43%; positive predictive value: 84%; and negative predictive value: 33%). This prospective, interventional observer-blinded study demonstrates that SVV obtained by APCO, using the FloTrac/Vigileo system, is not a reliable predictor of fluid responsiveness in the setting of major abdominal surgery.

  7. On the role of fluids in stick-slip dynamics of saturated granular fault gouge using a coupled computational fluid dynamics-discrete element approach: STICK-SLIP IN SATURATED FAULT GOUGE

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dorostkar, Omid; Guyer, Robert A.; Johnson, Paul A.

    The presence of fault gouge has considerable influence on slip properties of tectonic faults and the physics of earthquake rupture. The presence of fluids within faults also plays a significant role in faulting and earthquake processes. In this study, we present 3-D discrete element simulations of dry and fluid-saturated granular fault gouge and analyze the effect of fluids on stick-slip behavior. Fluid flow is modeled using computational fluid dynamics based on the Navier-Stokes equations for an incompressible fluid and modified to take into account the presence of particles. Analysis of a long time train of slip events shows that themore » (1) drop in shear stress, (2) compaction of granular layer, and (3) the kinetic energy release during slip all increase in magnitude in the presence of an incompressible fluid, compared to dry conditions. We also observe that on average, the recurrence interval between slip events is longer for fluid-saturated granular fault gouge compared to the dry case. This observation is consistent with the occurrence of larger events in the presence of fluid. It is found that the increase in kinetic energy during slip events for saturated conditions can be attributed to the increased fluid flow during slip. Finally, our observations emphasize the important role that fluid flow and fluid-particle interactions play in tectonic fault zones and show in particular how discrete element method (DEM) models can help understand the hydromechanical processes that dictate fault slip.« less

  8. On the role of fluids in stick-slip dynamics of saturated granular fault gouge using a coupled computational fluid dynamics-discrete element approach: STICK-SLIP IN SATURATED FAULT GOUGE

    DOE PAGES

    Dorostkar, Omid; Guyer, Robert A.; Johnson, Paul A.; ...

    2017-05-01

    The presence of fault gouge has considerable influence on slip properties of tectonic faults and the physics of earthquake rupture. The presence of fluids within faults also plays a significant role in faulting and earthquake processes. In this study, we present 3-D discrete element simulations of dry and fluid-saturated granular fault gouge and analyze the effect of fluids on stick-slip behavior. Fluid flow is modeled using computational fluid dynamics based on the Navier-Stokes equations for an incompressible fluid and modified to take into account the presence of particles. Analysis of a long time train of slip events shows that themore » (1) drop in shear stress, (2) compaction of granular layer, and (3) the kinetic energy release during slip all increase in magnitude in the presence of an incompressible fluid, compared to dry conditions. We also observe that on average, the recurrence interval between slip events is longer for fluid-saturated granular fault gouge compared to the dry case. This observation is consistent with the occurrence of larger events in the presence of fluid. It is found that the increase in kinetic energy during slip events for saturated conditions can be attributed to the increased fluid flow during slip. Finally, our observations emphasize the important role that fluid flow and fluid-particle interactions play in tectonic fault zones and show in particular how discrete element method (DEM) models can help understand the hydromechanical processes that dictate fault slip.« less

  9. Third Ventricular Cerebrospinal Fluid Cysts of Thalamic Origin: Review of Embryologic Origin, Presentation, and Management Strategies with a Case Series.

    PubMed

    Vasquez, Ciro A; Casey, Michael; Folzenlogen, Zach; Ormond, David R; Lillehei, Kevin; Youssef, A Samy

    2017-07-01

    Third ventricular cerebrospinal fluid (CSF) cysts of thalamic origin are rare. The objective of this study is to review their possible pathogenesis, clinical presentation, and management strategies with a case series describing management via an endoscopic approach with fenestration using a single burr-hole technique. A systematic literature review of reported cases of thalamic cysts was conducted with further meta-analysis of CSF cysts that involve the third ventricle. The mode of presentation, pathologic analysis, surgical management, and outcomes were analyzed. Twenty-two studies reported between 1990 and 2013 described 42 cases of thalamic cyst. Of those cases, 13 were consistent with CSF cyst that originated in the thalamus and involved the third ventricle. Eight cases (61.5%) were treated via endoscopic fenestration, 2 cases (15.4%) were surgically drained, 2 cases (15.4%) were stereotactically aspirated, and 1 case (7.69%) was observed. The most common presenting symptoms were gait disturbance (26.3%) and headaches (26.3%) followed by tremors (15.8%) and weakness (15.8%). In our series, a single burr-hole technique was a successful definitive treatment, with an average period of 23 months. Third ventricular CSF cysts of thalamic origin most commonly present with hydrocephalus. They can be safely definitively treated via endoscopic fenestration to the CSF circulation using a single burr-hole technique. Long-term follow-up shows lasting improvement in symptoms without reaccumulation of the cyst. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. Drying and wetting transitions of a Lennard-Jones fluid: Simulations and density functional theory

    NASA Astrophysics Data System (ADS)

    Evans, Robert; Stewart, Maria C.; Wilding, Nigel B.

    2017-07-01

    We report a theoretical and simulation study of the drying and wetting phase transitions of a truncated Lennard-Jones fluid at a flat structureless wall. Binding potential calculations predict that the nature of these transitions depends on whether the wall-fluid attraction has a long ranged (LR) power law decay or is instead truncated, rendering it short ranged (SR). Using grand canonical Monte Carlo simulation and classical density functional theory, we examine both cases in detail. We find that for the LR case wetting is first order, while drying is continuous (critical) and occurs exactly at zero attractive wall strength, i.e., in the limit of a hard wall. In the SR case, drying is also critical but the order of the wetting transition depends on the truncation range of the wall-fluid potential. We characterize the approach to critical drying and wetting in terms of the density and local compressibility profiles and via the finite-size scaling properties of the probability distribution of the overall density. For the LR case, where the drying point is known exactly, this analysis allows us to estimate the exponent ν∥, which controls the parallel correlation length, i.e., the extent of vapor bubbles at the wall. Surprisingly, the value we obtain is over twice that predicted by mean field and renormalization group calculations, despite the fact that our three dimensional system is at the upper critical dimension where mean field theory for critical exponents is expected to hold. Possible reasons for this discrepancy are discussed in the light of fresh insights into the nature of near critical finite-size effects.

  11. Drying and wetting transitions of a Lennard-Jones fluid: Simulations and density functional theory.

    PubMed

    Evans, Robert; Stewart, Maria C; Wilding, Nigel B

    2017-07-28

    We report a theoretical and simulation study of the drying and wetting phase transitions of a truncated Lennard-Jones fluid at a flat structureless wall. Binding potential calculations predict that the nature of these transitions depends on whether the wall-fluid attraction has a long ranged (LR) power law decay or is instead truncated, rendering it short ranged (SR). Using grand canonical Monte Carlo simulation and classical density functional theory, we examine both cases in detail. We find that for the LR case wetting is first order, while drying is continuous (critical) and occurs exactly at zero attractive wall strength, i.e., in the limit of a hard wall. In the SR case, drying is also critical but the order of the wetting transition depends on the truncation range of the wall-fluid potential. We characterize the approach to critical drying and wetting in terms of the density and local compressibility profiles and via the finite-size scaling properties of the probability distribution of the overall density. For the LR case, where the drying point is known exactly, this analysis allows us to estimate the exponent ν ∥ , which controls the parallel correlation length, i.e., the extent of vapor bubbles at the wall. Surprisingly, the value we obtain is over twice that predicted by mean field and renormalization group calculations, despite the fact that our three dimensional system is at the upper critical dimension where mean field theory for critical exponents is expected to hold. Possible reasons for this discrepancy are discussed in the light of fresh insights into the nature of near critical finite-size effects.

  12. Middle Ear Effusion in Children: A Report of Treatment in 500 Cases

    PubMed Central

    Forquer, Brian D.; Linthicum, Fred H.

    1982-01-01

    Records were studied of 500 children younger than 9 years of age with middle ear effusion who had received one of three treatment strategies: (1) administration of medication, including decongestants, antihistamines or antibiotics (or a combination), (2) administration of medication for a limited time and then surgical therapy if effusion did not resolve or (3) myringotomy done immediately with insertion of ventilation tubes and, in some cases, removal of adenoids. Early surgical intervention resulted in significantly shorter delay in hearing restoration. It did not result in a lower recurrence rate and it did not reduce the number of occasions when thick fluid, as compared with thin fluid, was found at operation. Four children for whom medical and surgical treatment failed were considered candidates for mild gain, low maximum-power-output hearing aids. All other children had normal hearing after treatment. Medication was successful in achieving this goal in 48 percent of the cases. PMID:6184891

  13. Fluid manipulation among individuals with lower urinary tract symptoms: a mixed methods study.

    PubMed

    Elstad, Emily A; Maserejian, Nancy N; McKinlay, John B; Tennstedt, Sharon L

    2011-01-01

    To determine, qualitatively and quantitatively, how individuals use fluid manipulation to self-manage the urinary symptoms of daytime frequency, urgency and urine leakage and the underlying rationale for this behaviour. Lower urinary tract symptoms are prevalent and burdensome, and little is known about how individuals with lower urinary tract symptoms manipulate their fluid intake. A mixed methods design included statistical analysis of data from a population-based survey of urologic symptoms and qualitative analysis of in-depth interviews. Quantitative data came from 5503 participants of the baseline Boston Area Community Health Survey, a population-based, random sample epidemiologic survey of urologic symptoms. Qualitative data came from in-depth interviews with a random subsample from Boston Area Community Health of 152 black, white and Hispanic men and women with LUTS. Qualitative data showed that some respondents restricted fluid intake while others increased it, in both cases with the expectation of improved symptoms. Quantitative data showed that fluid intake was greater in men and women reporting frequency (p < 0·001). Women with frequency drank significantly more water (p < 0·001), while women with urgency drank significantly less water (p = 0·047). This study found divergent expectations of the role of fluids in alleviating symptoms, leading some individuals to restrict and others to increase fluid intake. Individuals with lower urinary tract symptoms may need guidance in fluid management. Nurses should be aware that patients may self-manage lower urinary tract symptoms by restricting fluid intake, putting them at risk for dehydration, constipation and urinary tract infection, but also that they may be increasing their fluid intake, which could worsen symptoms. This study pinpoints a specific area of need among patients with lower urinary tract symptoms and provides a practical opportunity for nurses to assist their patients with behavioural and fluid management by emphasising the clinical guidelines. © 2010 Blackwell Publishing Ltd.

  14. Alpha-fetoprotein and its value for predicting pregnancy outcomes – a re-evaluation

    PubMed Central

    Darouich, Ayham Alhaj; Liehr, Thomas; Weise, Anja; Schlembach, Dietmar; Schleußner, Ekkehart; Kiehntopf, Michael; Schreyer, Isolde

    2015-01-01

    Introduction Alpha-fetoprotein (AFP) concentrations can be determined framing others from invasively acquired amnion fluid (AF-AFP). While the biological role of AFP remains unclear it is well known that AFP-levels can be altered in connection with specific clinical and/or genetic alterations of the fetus. Materials and Method here a retrospective study based on 3,119 singleton and 56 twin pregnancies is presented. The standard levels of amnion fluid derived alpha-fetoprotein level (AF-AFP) between 12th and 36th weeks of gestation were determined. Additionally, acetylcholinesterase (AChE) test results for 63 cases, ultrasonography results for 32 cases and abnormal karyotypic findings for 100 cases were available for selected cases. Results and Discussion according to the present data the AF-AFP test is reliable and provides expected test results in terms of population studies. However, individual AF-AFP test results can be subject to high individual variations. In this study AF-AFP multiple of medians (MoM) over 1.7 were indicative for neuronal tube defects and/or omphalocele in only 6.3% of the cases, while such AF-AFP values were hints on severe sonographic signs in 62% of the cases. Also, altered AF-AFP concentrations were present in 82% of cytogenetically abnormal cases. Overall, even though predicative value of the AF-AFP-test is matter of discussion it continues to be widely applied in invasive prenatal diagnostics. This study indicates that it only can be applied reliably in combination with other tests like banding cytogenetics, ultrasonography and all embedded in well-established genetic counseling. PMID:27358693

  15. 32 CFR 634.38 - Involuntary extraction of bodily fluids in traffic cases.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 32 National Defense 4 2010-07-01 2010-07-01 true Involuntary extraction of bodily fluids in traffic cases. 634.38 Section 634.38 National Defense Department of Defense (Continued) DEPARTMENT OF THE ARMY (CONTINUED) LAW ENFORCEMENT AND CRIMINAL INVESTIGATIONS MOTOR VEHICLE TRAFFIC SUPERVISION Traffic Supervision § 634.38 Involuntary extraction of...

  16. Paragonimiasis: a common cause of persistent pleural effusion in Lao PDR.

    PubMed

    Vidamaly, Sisoupanh; Choumlivong, Khamla; Keolouangkhot, Valy; Vannavong, Nanthasane; Kanpittaya, Jaturat; Strobel, Michel

    2009-10-01

    Southeast Asia is the major endemic area for paragonimiasis. Diagnosis relies on identification of ova in the sputum, pleural fluid or tissue specimen, or serology. Low awareness, however, frequently results in the disease being overlooked. We report nine cases presenting as primary, massive and protracted pleural effusions. All patients had evidence of Paragonimus spp. in the pleural fluid; one discharged an adult worm through a chest tube during treatment with praziquantel. In three cases, resolution of symptoms and pleural effusions could not be achieved, despite repeated fluid evacuation procedures and courses of praziquantel, which contradicts the widely accepted statement of paragonimiasis being self-limited and easy to cure. The disease should be considered in any case of elusive pleural effusion occurring in endemic areas.

  17. Filarial pleural effusion without peripheral blood or pleural fluid eosinophilia.

    PubMed

    Shukla, Amitabh Das; Chaudhary, Abhinav; Verma, Arvind Kumar; Anantha, Shreenivasa

    2017-09-19

    Lymphatic filariasis is a tropical parasitic disease and is endemic in India. It is present in various forms but its manifestation as pleural effusion is rare. Here, we describe a case of 58-year-old male who presented with complaint of left side chest pain and breathlessness. He was investigated and diagnosed as a case of left side pleural effusion due to filariasis, with peripheral blood lymphocytosis but without peripheral blood or pleural fluid eosinophilia. Our case foregrounds that filariasis can present with peripheral blood lymphocytosis and without peripheral blood or pleural fluid eosinophilia. © BMJ Publishing Group Ltd (unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  18. Percutaneous cardiopulmonary support to treat suspected venous air embolism with cardiac arrest during open eye surgery: a case report.

    PubMed

    Shin, Seokyung; Nam, Bokyung; Soh, Sarah; Koo, Bon-Nyeo

    2014-11-01

    We report a case of possible venous air embolism (VAE) during trans pars plana vitrectomy with air-fluid exchange of the vitreous cavity. Shortly after initiation of air-fluid exchange, decreases in end-tidal CO2, oxygen saturation, and blood pressure were observed. The patient rapidly progressed to cardiac arrest unresponsive to cardiopulmonary resuscitation, and recovered after the application of percutaneous cardiopulmonary support. Prompt termination of air infusion is needed when VAE is suspected during air-fluid exchange, and extracorporeal life support should be considered in fatal cases. Although the incidence is rare the possibility of VAE during ophthalmic surgery clearly exists, and therefore awareness and vigilant monitoring seem critical.

  19. Twisting microfluidics in a planetary centrifuge.

    PubMed

    Yasuda, Shoya; Hayakawa, Masayuki; Onoe, Hiroaki; Takinoue, Masahiro

    2017-03-15

    This paper reports a twisting microfluidic method utilising a centrifuge-based fluid extruding system in a planetary centrifuge which simultaneously generates an orbital rotation and an axial spin. In this method, fluid extrusion from a micro-scale capillary to an 'open-space' solution or air enables release of the fluid from the capillary-based microchannel, which physically means that there is a release of fluids from a confined low-Reynolds-number environment to an open non-low-Reynolds-number environment. As a result, the extruded fluids are separated from the axial spin of the capillary, and the difference in the angular rates of the axial spin between the capillary and the extruded fluids produces the 'twisting' of the fluid. In this study, we achieve control of the twist of highly viscous fluids, and we construct a simple physical model for the fluid twist. In addition, we demonstrate the formation of twisted hydrogel microstructures (stripe-patterned microbeads and multi-helical microfibres) with control over the stripe pattern and the helical pitch length. We believe that this method will enable the generation of more sophisticated microstructures which cannot easily be formed by usual channel-based microfluidic devices. This method can also provide advanced control of microfluids, as in the case of rapid mixing of highly viscous fluids. This method can contribute to a wide range of applications in materials science, biophysics, biomedical science, and microengineering in the future.

  20. Viscous-elastic dynamics of power-law fluids within an elastic cylinder

    NASA Astrophysics Data System (ADS)

    Boyko, Evgeniy; Bercovici, Moran; Gat, Amir D.

    2017-07-01

    In a wide range of applications, microfluidic channels are implemented in soft substrates. In such configurations, where fluidic inertia and compressibility are negligible, the propagation of fluids in channels is governed by a balance between fluid viscosity and elasticity of the surrounding solid. The viscous-elastic interactions between elastic substrates and non-Newtonian fluids are particularly of interest due to the dependence of viscosity on the state of the system. In this work, we study the fluid-structure interaction dynamics between an incompressible non-Newtonian fluid and a slender linearly elastic cylinder under the creeping flow regime. Considering power-law fluids and applying the thin shell approximation for the elastic cylinder, we obtain a nonhomogeneous p-Laplacian equation governing the viscous-elastic dynamics. We present exact solutions for the pressure and deformation fields for various initial and boundary conditions for both shear-thinning and shear-thickening fluids. We show that in contrast to Stokes' problem where a compactly supported front is obtained for shear-thickening fluids, here the role of viscosity is inversed and such fronts are obtained for shear-thinning fluids. Furthermore, we demonstrate that for the case of a step in inlet pressure, the propagation rate of the front has a tn/n +1 dependence on time (t ), suggesting the ability to indirectly measure the power-law index (n ) of shear-thinning liquids through measurements of elastic deformation.

  1. Submarine gas seepage in a mixed contractional and shear deformation regime: Cases from the Hikurangi oblique-subduction margin

    NASA Astrophysics Data System (ADS)

    Plaza-Faverola, Andreia; Pecher, Ingo; Crutchley, Gareth; Barnes, Philip M.; Bünz, Stefan; Golding, Thomas; Klaeschen, Dirk; Papenberg, Cord; Bialas, Joerg

    2014-02-01

    Gas seepage from marine sediments has implications for understanding feedbacks between the global carbon reservoir, seabed ecology, and climate change. Although the relationship between hydrates, gas chimneys, and seafloor seepage is well established, the nature of fluid sources and plumbing mechanisms controlling fluid escape into the hydrate zone and up to the seafloor remain one of the least understood components of fluid migration systems. In this study, we present the analysis of new three-dimensional high-resolution seismic data acquired to investigate fluid migration systems sustaining active seafloor seepage at Omakere Ridge, on the Hikurangi subduction margin, New Zealand. The analysis reveals at high resolution, complex overprinting fault structures (i.e., protothrusts, normal faults from flexural extension, and shallow (<1 km) arrays of oblique shear structures) implicated in fluid migration within the gas hydrate stability zone in an area of 2 × 7 km. In addition to fluid migration systems sustaining seafloor seepage on both sides of a central thrust fault, the data show seismic evidence for subseafloor gas-rich fluid accumulation associated with proto-thrusts and extensional faults. In these latter systems fluid pressure dissipation through time has been favored, hindering the development of gas chimneys. We discuss the elements of the distinct fluid migration systems and the influence that a complex partitioning of stress may have on the evolution of fluid flow systems in active subduction margins.

  2. Causal implications of viscous damping in compressible fluid flows

    PubMed

    Jordan; Meyer; Puri

    2000-12-01

    Classically, a compressible, isothermal, viscous fluid is regarded as a mathematical continuum and its motion is governed by the linearized continuity, Navier-Stokes, and state equations. Unfortunately, solutions of this system are of a diffusive nature and hence do not satisfy causality. However, in the case of a half-space of fluid set to motion by a harmonically vibrating plate the classical equation of motion can, under suitable conditions, be approximated by the damped wave equation. Since this equation is hyperbolic, the resulting solutions satisfy causal requirements. In this work the Laplace transform and other analytical and numerical tools are used to investigate this apparent contradiction. To this end the exact solutions, as well as their special and limiting cases, are found and compared for the two models. The effects of the physical parameters on the solutions and associated quantities are also studied. It is shown that propagating wave fronts are only possible under the hyperbolic model and that the concept of phase speed has different meanings in the two formulations. In addition, discontinuities and shock waves are noted and a physical system is modeled under both formulations. Overall, it is shown that the hyperbolic form gives a more realistic description of the physical problem than does the classical theory. Lastly, a simple mechanical analog is given and connections to viscoelastic fluids are noted. In particular, the research presented here supports the notion that linear compressible, isothermal, viscous fluids can, at least in terms of causality, be better characterized as a type of viscoelastic fluid.

  3. Cerebrospinal fluid viral breakthrough in two HIV-infected subjects on darunavir/ritonavir monotherapy

    PubMed Central

    2012-01-01

    Darunavir/ritonavir monotherapy maintains HIV suppression in most patients who have achieved an undetectable viral load on combination antiretroviral treatment, and is increasingly used in the clinic. However, concerns have been raised about the effectiveness of ritonavir-boosted protease inhibitor (PI/r) monotherapy in the prevention of HIV replication in the central nervous system (CNS). Here we report the cases of 2 patients on darunavir/r maintenance monotherapy with cerebrospinal fluid viral breakthrough together with increased immunoactivation and biomarker signs of neuronal injury. These 2 cases raise concerns about the effectiveness of darunavir/ritonavir monotherapy in HIV CNS infection. Thus, we recommend caution with protease inhibitor monotherapy until CNS results have been obtained from clinical studies. PMID:22776013

  4. Cerebrospinal fluid viral breakthrough in two HIV-infected subjects on darunavir/ritonavir monotherapy.

    PubMed

    Gisslén, Magnus; Fuchs, Dietmar; Hagberg, Lars; Svennerholm, Bo; Zetterberg, Henrik

    2012-12-01

    Darunavir/ritonavir monotherapy maintains HIV suppression in most patients who have achieved an undetectable viral load on combination antiretroviral treatment, and is increasingly used in the clinic. However, concerns have been raised about the effectiveness of ritonavir-boosted protease inhibitor (PI/r) monotherapy in the prevention of HIV replication in the central nervous system (CNS). Here we report the cases of 2 patients on darunavir/r maintenance monotherapy with cerebrospinal fluid viral breakthrough together with increased immunoactivation and biomarker signs of neuronal injury. These 2 cases raise concerns about the effectiveness of darunavir/ritonavir monotherapy in HIV CNS infection. Thus, we recommend caution with protease inhibitor monotherapy until CNS results have been obtained from clinical studies.

  5. Interface Fluid Syndrome After Laser In Situ Keratomileusis (LASIK) Because of Fuchs Endothelial Dystrophy Reversed by Descemet Membrane Endothelial Keratoplasty (DMEK).

    PubMed

    Luceri, Salvatore; Baksoellah, Zainab; Ilyas, Abbas; Baydoun, Lamis; Melles, Gerrit R J

    2016-12-01

    To describe a case that developed "interface fluid syndrome" after previous laser in situ keratomileusis (LASIK) because of Fuchs endothelial dystrophy (FED), which was reversed by Descemet membrane endothelial keratoplasty (DMEK). A 58-year-old male patient presented with bilateral visual impairment owing to FED and visually significant cataract. Cataract surgery was carried out in both eyes followed by DMEK in his left eye. After cataract surgery, visual acuity did not improve sufficiently because corneal thickness increased and a fine cleft with interface fluid developed between the LASIK-flap and the residual stromal bed. After uneventful DMEK in his left eye, the fluid resolved within a week and visual acuity improved rapidly. This case demonstrates that "interface fluid syndrome" after LASIK caused by concomitant endothelial dysfunction may be reversed by DMEK allowing fast visual recovery.

  6. Fluid mechanics as a driver of tissue-scale mechanical signaling in organogenesis

    PubMed Central

    Gilbert, Rachel M.; Morgan, Joshua T.; Marcin, Elizabeth S.; Gleghorn, Jason P.

    2016-01-01

    Purpose of Review Organogenesis is the process during development by which cells self-assemble into complex, multi-scale tissues. Whereas significant focus and research effort has demonstrated the importance of solid mechanics in organogenesis, less attention has been given to the fluid forces that provide mechanical cues over tissue length scales. Recent Findings Fluid motion and pressure is capable of creating spatial gradients of forces acting on cells, thus eliciting distinct and localized signaling patterns essential for proper organ formation. Understanding the multi-scale nature of the mechanics is critically important to decipher how mechanical signals sculpt developing organs. Summary This review outlines various mechanisms by which tissues generate, regulate, and sense fluid forces and highlights the impact of these forces and mechanisms in case studies of normal and pathological development. PMID:28163984

  7. Lattice Boltzmann model for three-phase viscoelastic fluid flow

    NASA Astrophysics Data System (ADS)

    Xie, Chiyu; Lei, Wenhai; Wang, Moran

    2018-02-01

    A lattice Boltzmann (LB) framework is developed for simulation of three-phase viscoelastic fluid flows in complex geometries. This model is based on a Rothman-Keller type model for immiscible multiphase flows which ensures mass conservation of each component in porous media even for a high density ratio. To account for the viscoelastic effects, the Maxwell constitutive relation is correctly introduced into the momentum equation, which leads to a modified lattice Boltzmann evolution equation for Maxwell fluids by removing the normal but excess viscous term. Our simulation tests indicate that this excess viscous term may induce significant errors. After three benchmark cases, the displacement processes of oil by dispersed polymer are studied as a typical example of three-phase viscoelastic fluid flow. The results show that increasing either the polymer intrinsic viscosity or the elastic modulus will enhance the oil recovery.

  8. Partial slip effect on non-aligned stagnation point nanofluid over a stretching convective surface

    NASA Astrophysics Data System (ADS)

    Nadeem, S.; Rashid, Mehmood; Noreen Sher, Akbar

    2015-01-01

    The present study inspects the non-aligned stagnation point nano fluid over a convective surface in the presence of partial slip.Two types of base fluids namely water and kerosene are selected with Cu nanoparticles. The governing physical problem is presented and transformed into a system of coupled nonlinear differential equations using suitable similarity transformations. These equations are then solved numerically using midpoint integration scheme along with Richardson extrapolation via Maple. Impact of relevant physical parameters on the dimensionless velocity and temperature profiles are portrayed through graphs. Physical quantities such as local skin frictions co-efficient and Nusselt numbers are tabularized. It is detected from numerical computations that kerosene-based nano fluids have better heat transfer capability compared with water-based nanofluids. Moreover it is found that water-based nanofluids offer less resistance in terms of skin friction than kerosene-based fluid. In order to authenticate our present study, the calculated results are compared with the prevailing literature and a considerable agreement is perceived for the limiting case.

  9. Asbestos bodies in bronchoalveolar lavage fluid. A study of 20 asbestos-exposed individuals and comparison to patients with other chronic interstitial lung diseases

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Roggli, V.L.; Piantadosi, C.A.; Bell, D.Y.

    1986-09-01

    We studied the asbestos body (AB) content of bronchoalveolar lavage fluid from 20 patients with a history of occupational asbestos exposure, 31 patients with sarcoidosis and 5 patients with idiopathic pulmonary fibrosis. The cellular lavage pellet was digested in sodium hypochlorite and filtered onto Nuclepore filters for AB quantification by light microscopy. ABs were found in 15 of 20 asbestos-exposed individuals, 9 of 31 sarcoidosis cases and 2 of 5 patients with idiopathic pulmonary fibrosis. There was a statistically significant difference in the number of ABs per million cells recovered or per milliliter of recovered lavage fluid in the asbestos-exposedmore » group as compared to the other categories of chronic interstitial lung disease. The highest levels occurred in patients with asbestosis. Large numbers of asbestos bodies in the lavage fluid (greater than 1 AB/10(6) cells) were indicative of considerable occupational asbestos exposure, whereas occasional bodies were a nonspecific finding.« less

  10. Proteomic Analysis of Synovial Fluid Obtained From a Dog Diagnosed With Idiopathic Immune-Mediated Polyarthritis.

    PubMed

    Tan, Wei Miao; Lau, Seng Fong; Ajat, Mokrish; Mansor, Rozaihan; Abd Rani, Puteri Azaziah Megat; Rahmad, Norasfaliza Binti

    2017-03-01

    This case study is to report the proteins detected by proteomic analysis of synovial fluid from a dog diagnosed with idiopathic immune-mediated polyarthritis, and to compare it with healthy dogs. Synovial fluid was collected via arthrocentesis from a dog diagnosed with immune-mediated polyarthritis. Protein precipitation was performed on the synovial fluid, followed by isoelectric focusing and 2-dimensional gel electrophoresis. The spots on the 2-dimensional gels were analyzed using MALDI-TOF/MS. The results were then analyzed against the MASCOT database. The results from the proteomic analysis revealed an abundance of several types of immunoglobulins together with the presence of complement C4b-binding protein alpha chain. Actin and keratin were also among the proteins detected. Proteomic studies, facilitate a better understanding of the different levels of proteins expressed during disease activity. Potential disease biomarkers can aid in the diagnosis of disease, as well as help in monitoring treatment efficacy and providing prognosis for the patient. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. An analytical study of reduced-gravity flow dynamics

    NASA Technical Reports Server (NTRS)

    Bradshaw, R. D.; Kramer, J. L.; Zich, J. L.

    1976-01-01

    Addition of surface tension forces to a marker-and-cell code and the performance of four incompressible fluid simulations in reduced gravity, were studied. This marker-and-cell code has a variable grid capability with arbitrary curved boundaries and time dependent acceleration fields. The surface tension logic includes a spline fit of surface marker particles as well as contact angle logic for straight and curved wall boundaries. Three types of flow motion were simulated with the improved code: impulsive settling in a model Centaur LH2 tank, continuous settling in a model and full scale Centaur LO2 tank and mixing in a Centaur LH2 tank. The impulsive settling case confirmed a drop tower analysis which indicated more orderly fluid collection flow patterns with this method providing a potential savings in settling propellants. In the LO2 tank, fluid collection and flow simulation into the thrust barrel were achieved. The mixing simulation produced good results indicating both the development of the flow field and fluid interface behavior.

  12. Dispersion effects in the miscible displacement of two fluids in a duct of large aspect ratio

    NASA Astrophysics Data System (ADS)

    Zhang, J.; Frigaard, I. A.

    We study miscible displacements in long ducts in the dispersive limit of small \\varepsilon Pe, where \\varepsilon ≪ 1 is the inverse aspect ratio and Pe the Péclet number. We consider the class of generalized Newtonian fluids, with specified closure laws for the fluid properties of the concentration-dependent mixture. Regardless of viscosity ratio and the constitutive laws of the pure fluids, for sufficiently small \\varepsilon Pe these displacements are characterized by rapid cross-stream diffusion and slow streamwise dispersion, i.e. the concentration appears to be near-uniform across the duct and spreads slowly as it translates. Using the multiple-scales method we derive the leading-order asymptotic approximation to the average fluid concentration bar{c}_0. We show that bar{c}_0 evolves on the slow timescale t ˜ (\\varepsilon Pe)^{-1}, and satisfies a nonlinear diffusion equation in a frame of reference moving with the mean speed of the flow. In the case that the two fluids have identical rheologies and the concentration represents a passive tracer, the diffusion equation is linear. For Newtonian fluids we recover the classical results of Taylor (l953), Aris (1956), and for power-law fluids those of Vartuli et al. (1995). In the case that the fluids differ and/or that mixing is non-passive, bar{c}_0 satisfies a nonlinear diffusion equation in the moving frame of reference. Given a specific mixing/closure law for the rheological properties, we are able to compute the dispersive diffusivity D_T(bar{c}_0) and predict spreading along the channel. We show that D_T(bar{c}_0) can vary significantly with choice of mixing law and discuss why. This also opens the door to possibilities of controlling streamwise spreading by the rheological design of reactive mixtures, i.e. including chemical additives such that the rheology of the mixture behaves very differently to the rheology of either pure fluid. Computed examples illustrate the potential effects that might be achieved.

  13. Solitary water wave interactions

    NASA Astrophysics Data System (ADS)

    Craig, W.; Guyenne, P.; Hammack, J.; Henderson, D.; Sulem, C.

    2006-05-01

    This article concerns the pairwise nonlinear interaction of solitary waves in the free surface of a body of water lying over a horizontal bottom. Unlike solitary waves in many completely integrable model systems, solitary waves for the full Euler equations do not collide elastically; after interactions, there is a nonzero residual wave that trails the post-collision solitary waves. In this report on new numerical and experimental studies of such solitary wave interactions, we verify that this is the case, both in head-on collisions (the counterpropagating case) and overtaking collisions (the copropagating case), quantifying the degree to which interactions are inelastic. In the situation in which two identical solitary waves undergo a head-on collision, we compare the asymptotic predictions of Su and Mirie [J. Fluid Mech. 98, 509 (1980)] and Byatt-Smith [J. Fluid Mech. 49, 625 (1971)], the wavetank experiments of Maxworthy [J. Fluid Mech. 76, 177 (1976)], and the numerical results of Cooker, Weidman, and Bale [J. Fluid Mech. 342, 141 (1997)] with independent numerical simulations, in which we quantify the phase change, the run-up, and the form of the residual wave and its Fourier signature in both small- and large-amplitude interactions. This updates the prior numerical observations of inelastic interactions in Fenton and Rienecker [J. Fluid Mech. 118, 411 (1982)]. In the case of two nonidentical solitary waves, our precision wavetank experiments are compared with numerical simulations, again observing the run-up, phase lag, and generation of a residual from the interaction. Considering overtaking solitary wave interactions, we compare our experimental observations, numerical simulations, and the asymptotic predictions of Zou and Su [Phys. Fluids 29, 2113 (1986)], and again we quantify the inelastic residual after collisions in the simulations. Geometrically, our numerical simulations of overtaking interactions fit into the three categories of Korteweg-deVries two-soliton solutions defined in Lax [Commun. Pure Appl. Math. 21, 467 (1968)], with, however, a modification in the parameter regime. In all cases we have considered, collisions are seen to be inelastic, although the degree to which interactions depart from elastic is very small. Finally, we give several theoretical results: (i) a relationship between the change in amplitude of solitary waves due to a pairwise collision and the energy carried away from the interaction by the residual component, and (ii) a rigorous estimate of the size of the residual component of pairwise solitary wave collisions. This estimate is consistent with the analytic results of Schneider and Wayne [Commun. Pure Appl. Math. 53, 1475 (2000)], Wright [SIAM J. Math. Anal. 37, 1161 (2005)], and Bona, Colin, and Lannes [Arch. Rat. Mech. Anal. 178, 373 (2005)]. However, in light of our numerical data, both (i) and (ii) indicate a need to reevaluate the asymptotic results in Su and Mirie [J. Fluid Mech. 98, 509 (1980)] and Zou and Su [Phys. Fluids 29, 2113 (1986)].

  14. Subretinal fluid is common in experimental non-arteritic anterior ischemic optic neuropathy

    PubMed Central

    Yu, C; Ho, J K; Liao, Y J

    2014-01-01

    Purpose Anterior ischemic optic neuropathy (AION) is an important cause of acute vision loss for which several animal models exist. It has been associated with subretinal fluid in a previous study on patients but not yet so in animal models. Patients and Methods A patient presented with acute non-arteritic AION (NAION) and underwent ophthalmic evaluation and testing including fluorescein angiography and spectral-domain optical coherence tomography (SD-OCT). On the basis of the patient's findings, we used SD-OCT circular and volume scans to analyze retinal changes in a murine model of NAION. Results One week after left eye vision loss, the patient had clinical and imaging findings consistent with NAION. On SD-OCT, there was prominent peripapillary retinal thickening consistent with intra-retinal edema and sub-foveolar fluid. Inspired by the findings in human AION, we looked for similar changes in murine NAION using SD-OCT. The circular scan did not adequately detect the presence of subretinal fluid. Using the 25-line scan, which covered a larger part of the posterior pole, we found that 100% of murine AION resulted in subretinal fluid at day 1. The subretinal fluid resolved by week 1. Conclusion This study detailed a case of clinical NAION associated with intra-retinal and subretinal fluid. We also found that subretinal fluid was common in murine photochemical thrombosis model of AION and could be found far away from the optic disc. PMID:25257770

  15. Vitreous Fluid and/or Urine Glucose Concentrations in 1,335 Civil Aviation Accident Pilot Fatalities

    DTIC Science & Technology

    2008-05-01

    glucose, and in those cases wherein glucose levels are elevated, blood hemoglobin A1c ( HbA1c ) is measured. These analyses are conducted to monitor...diabetes. In this study, the prevalence of elevated glucose concentrations in fatally injured civilian pilots is evaluated. Glucose and HbA1c are measured...whom samples were received during 1998–2005 and whose vitreous fluid and/or urine glucose concentrations were measured. HbA1c levels and information

  16. Initial Parameter Estimation for Inverse Thermal Analysis of Ti-6Al-4V Deep Penetration Welds

    DTIC Science & Technology

    2014-05-16

    theory, for the case of deep-penetration welding, is simulation of the coupling of keyhole formation, melting, fluid flow in the weld melt pool and...isothermal boundaires, e.g., TTB and TM. A specific procedure for interpolation, however, has not been considered. For the present study, the close ...Clarendon Press, Oxford, 2nd ed, 374, 1959. 19. R. Rai, J.W. Elmer, T.A. Palmer, T. DebRoy, Heat Transfer and Fluid Flow During Keyhole Mode Laser Welding

  17. Fracture stimulation treatment design optimization: What can the NPV vs X{sub f} plot tell us?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Huffman, C.H.; Harkrider, J.D.; Thompson, R.S.

    1996-12-31

    Fracture stimulation production response coupled with the hydrocarbon sales price determines the value of a fracture stimulation treatment. Many factors can significantly effect the production response of a fracture stimulated well. Some examples include stimulation fluid selection, proppant selection, pumping rates, rock properties, reservoir fluid properties, in-situ stresses, stress variations, on-site execution, post-treatment stimulation fluid recovery, and operating practices. The production response in economic terms portrays the net effect of these variables. This paper presents a case study that demonstrates how post-treatment evaluations expressed in economic terms can be used to assess the performance of stimulations and to guide futuremore » design choices.« less

  18. Accuracy of different diagnostic tests for early, delayed and late prosthetic joint infection.

    PubMed

    Fernández-Sampedro, M; Fariñas-Alvarez, C; Garces-Zarzalejo, C; Alonso-Aguirre, M A; Salas-Venero, C; Martínez-Martínez, L; Fariñas, M C

    2017-08-25

    A combination of laboratory, histopathological and microbiological tests for diagnosis of prosthetic joint infection (PJI) have been strongly recommended. This study aims to characterize the accuracy of individual or group tests, such as culture of sonicate fluid, synovial fluid and peri-implant tissue, C-reactive protein (CRP) and histopathology for detection of early, delayed and late PJI. A prospective study of patients undergoing hip or knee arthroplasty from February 2009 to February 2014 was performed in a Spanish tertiary health care hospital. The diagnostic accuracy of the different methods was evaluated constructing receiver-operating-characteristic (ROC) curve areas. One hundred thirty consecutive patients were included: 18 (13.8%) early PJI, 35 (27%) delayed PJI and 77 (59.2%) late PJI. For individual parameters, the area under the ROC curve for peri-implant tissue culture was larger for early (0.917) than for delayed (0.829) and late PJI (0.778), p = 0.033. There was a significantly larger difference for ROC area in the synovial fluid culture for delayed (0.803) than for early (0.781) and late infections (0.679), p = 0.039. The comparison of the areas under the ROC curves for the two microbiological tests showed that sonicate fluid was significantly different from peri-implant tissue in delayed (0.951 vs 0.829, p = 0.005) and late PJI (0.901 vs 0.778, p = 0.000). The conjunction of preoperative parameters, synovial fluid culture and CRP, improved the accuracy for late PJI (p = 0.01). The conjunction of histopathology and sonicate fluid culture increased the area under ROC curve of sonication in early (0.917 vs 1.000); p = 0.06 and late cases (0.901 vs 0.999); p < 0.001. For early PJI, sonicate fluid and peri-implant tissue cultures achieve the same best sensitivity. For delayed and late PJI, sonicate fluid culture is the most sensitive individual diagnostic method. By combining histopathology and peri-implant tissue, all early, 97% of delayed and 94.8% of late cases are diagnosed. The conjunction of histopathology and sonicate fluid culture yields a sensitivity of 100% for all types of infection.

  19. Cochlear perfusion with a viscous fluid.

    PubMed

    Wang, Yi; Olson, Elizabeth S

    2016-07-01

    The flow of viscous fluid in the cochlea induces shear forces, which could provide benefit in clinical practice, for example to guide cochlear implant insertion or produce static pressure to the cochlear partition or wall. From a research standpoint, studying the effects of a viscous fluid in the cochlea provides data for better understanding cochlear fluid mechanics. However, cochlear perfusion with a viscous fluid may damage the cochlea. In this work we studied the physiological and anatomical effects of perfusing the cochlea with a viscous fluid. Gerbil cochleae were perfused at a rate of 2.4 μL/min with artificial perilymph (AP) and sodium hyaluronate (Healon, HA) in four different concentrations (0.0625%, 0.125%, 0.25%, 0.5%). The different HA concentrations were applied either sequentially in the same cochlea or individually in different cochleae. The perfusion fluid entered from the round window and was withdrawn from basal scala vestibuli, in order to perfuse the entire perilymphatic space. Compound action potentials (CAP) were measured after each perfusion. After perfusion with increasing concentrations of HA in the order of increasing viscosity, the CAP thresholds generally increased. The threshold elevation after AP and 0.0625% HA perfusion was small or almost zero, and the 0.125% HA was a borderline case, while the higher concentrations significantly elevated CAP thresholds. Histology of the cochleae perfused with the 0.0625% HA showed an intact Reissner's membrane (RM), while in cochleae perfused with 0.125% and 0.25% HA RM was torn. Thus, the CAP threshold elevation was likely due to the broken RM, likely caused by the shear stress produced by the flow of the viscous fluid. Our results and analysis indicate that the cochlea can sustain, without a significant CAP threshold shift, up to a 1.5 Pa shear stress. Beside these finding, in the 0.125% and 0.25% HA perfusion cases, a temporary CAP threshold shift was observed, perhaps due to the presence and then clearance of viscous fluid within the cochlea, or to a temporary position shift of the Organ of Corti. After 0.5% HA perfusion, a short latency positive peak (P0) appeared in the CAP waveform. This P0 might be due to a change in the cochlea's traveling-wave pattern, or distortion in the cochlear microphonic. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. Cochlear perfusion with a viscous fluid

    PubMed Central

    Wang, Yi; Olson, Elizabeth S.

    2016-01-01

    The flow of viscous fluid in the cochlea induces shear forces, which could provide benefit in clinical practice, for example to guide cochlear implant insertion or produce static pressure to the cochlear partition or wall. From a research standpoint, studying the effects of a viscous fluid in the cochlea provides data for better understanding cochlear fluid mechanics. However, cochlear perfusion with a viscous fluid may damage the cochlea. In this work we studied the physiological and anatomical effects of perfusing the cochlea with a viscous fluid. Gerbil cochleae were perfused at a rate of 2.4 μL/min with artificial perilymph (AP) and sodium hyaluronate (Healon, HA) in four different concentrations (0.0625%, 0.125%, 0.25%, 0.5%). The different HA concentrations were applied either sequentially in the same cochlea or individually in different cochleae. The perfusion fluid entered from the round window and was withdrawnfrom basal scala vestibuli, in order to perfuse the entire perilymphatic space. Compound action potentials (CAP) were measured after each perfusion. After perfusion with increasing concentrations of HA in the order of increasing viscosity, the CAP thresholds generally increased. The threshold elevation after AP and 0.0625% HA perfusion was small or almost zero, and the 0.125% HA was a borderline case, while the higher concentrations significantly elevated CAP thresholds. Histology of the cochleae perfused with the 0.0625% HA showed an intact Reissner’s membrane, while in cochleae perfused with 0.125% and 0.25% HA Reissner’s membrane (RM) was torn. Thus, the CAP threshold elevation was likely due to the broken of RM, which likely caused by the shear stress produced by the flow of the viscous fluid. Our results and analysis indicate that the cochlea can sustain, without a significant CAP threshold shift, up to a 1.5 Pa shear stress. Beside these finding, in the 0.125% and 0.25% HA perfusion cases, a temporary CAP threshold shift was observed, perhaps due to the presence and then clearance of viscous fluid within the cochlea, or to a temporary position shift of the Organ of Corti. After 0.5% HA perfusion, a short latency positive peak (P0) appeared in the CAP wavefrom. This P0 might be due to a change in the cochlea’s traveling-wave pattern, or distortion in the cochlear microphonic. PMID:27220484

  1. Performance comparison of different thermodynamic cycles for an innovative central receiver solar power plant

    NASA Astrophysics Data System (ADS)

    Reyes-Belmonte, Miguel A.; Sebastián, Andrés; González-Aguilar, José; Romero, Manuel

    2017-06-01

    The potential of using different thermodynamic cycles coupled to a solar tower central receiver that uses a novel heat transfer fluid is analyzed. The new fluid, named as DPS, is a dense suspension of solid particles aerated through a tubular receiver used to convert concentrated solar energy into thermal power. This novel fluid allows reaching high temperatures at the solar receiver what opens a wide range of possibilities for power cycle selection. This work has been focused into the assessment of power plant performance using conventional, but optimized cycles but also novel thermodynamic concepts. Cases studied are ranging from subcritical steam Rankine cycle; open regenerative Brayton air configurations at medium and high temperature; combined cycle; closed regenerative Brayton helium scheme and closed recompression supercritical carbon dioxide Brayton cycle. Power cycle diagrams and working conditions for design point are compared amongst the studied cases for a common reference thermal power of 57 MWth reaching the central cavity receiver. It has been found that Brayton air cycle working at high temperature or using supercritical carbon dioxide are the most promising solutions in terms of efficiency conversion for the power block of future generation by means of concentrated solar power plants.

  2. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cheng, M., E-mail: chengm@ihpc.a-star.edu.sg; Lou, J.; Lim, T. T.

    A recent theoretical study [Borisov, Kilin, and Mamaev, “The dynamics of vortex rings: Leapfrogging, choreographies and the stability problem,” Regular Chaotic Dyn. 18, 33 (2013); Borisov et al., “The dynamics of vortex rings: Leapfrogging in an ideal and viscous fluid,” Fluid Dyn. Res. 46, 031415 (2014)] shows that when three coaxial vortex rings travel in the same direction in an incompressible ideal fluid, each of the vortex rings alternately slips through (or leapfrogs) the other two ahead. Here, we use a lattice Boltzmann method to simulate viscous vortex rings with an identical initial circulation, radius, and separation distance with themore » aim of studying how viscous effect influences the outcomes of the leapfrogging process. For the case of two identical vortex rings, our computation shows that leapfrogging can be achieved only under certain favorable conditions, which depend on Reynolds number, vortex core size, and initial separation distance between the two rings. For the case of three coaxial vortex rings, the result differs from the inviscid model and shows that the second vortex ring always slips through the leading ring first, followed by the third ring slipping through the other two ahead. A simple physical model is proposed to explain the observed behavior.« less

  3. Response to “Comment on ‘General rotating quantum vortex filaments in the low-temperature Svistunov model of the local induction approximation’” [Phys. Fluids 26, 119101 (2014)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Van Gorder, Robert A., E-mail: rav@knights.ucf.edu

    2014-11-15

    In R. A. Van Gorder, “General rotating quantum vortex filaments in the low-temperature Svistunov model of the local induction approximation,” Phys. Fluids 26, 065105 (2014) I discussed properties of generalized vortex filaments exhibiting purely rotational motion under the low-temperature Svistunov model of the local induction approximation. Such solutions are stationary in terms of translational motion. In the Comment [N. Hietala, “Comment on ‘General rotating quantum vortex filaments in the low-temperature Svistunov model of the local induction approximation’ [Phys. Fluids 26, 065105 (2014)],” Phys. Fluids 26, 119101 (2014)], the author criticizes my paper for not including translational motion (although it wasmore » clearly stated that the filament motion was assumed rotational). As it turns out, if one is interested in studying the geometric structure of solutions (which was the point of my paper), one obtains the needed qualitative results on the structure of such solutions by studying the purely rotational case. Nevertheless, in this Response I shall discuss the vortex filaments that have both rotational and translational motions. I then briefly discuss why one might want to study such generalized rotating filament solutions, in contrast to simple the standard helical or planar examples (which are really special cases). I also discuss how one can study the time evolution of filaments which exhibit more complicated dynamics than pure translation and rotation. Doing this, one can study non-stationary solutions which initially appear purely rotational and gradually display other dynamics as the filaments evolve.« less

  4. Syndrome of transient headache and neurological deficits with cerebrospinal fluid lymphocytosis (HaNDL): A case report with serial electroencephalography (EEG) recordings.. Is there an association with human herpes virus type 7 (HHV-7) infection?

    PubMed

    Stelten, Bianca Ml; Venhovens, Jeroen; van der Velden, Lieven Bj; Meulstee, Jan; Verhagen, Wim Im

    2016-11-01

    Introduction The syndrome of transient headache and neurological deficits with cerebrospinal fluid lymphocytosis (HaNDL) is a diagnosis made by exclusion. In the literature, different etiological explanations are proposed for HaNDL, including an immune-mediated reaction after a viral infection. Case description We present a case of a 23-year-old woman with several episodes of transient headache, neurological deficits and cerebrospinal fluid lymphocytosis. All diagnostic criteria for the HaNDL syndrome were fulfilled; however, additional cerebrospinal fluid analysis showed a positive polymerase chain reaction (PCR) for human herpes virus type 7 (HHV-7). Discussion The possible role of a (prodromal) viral infection in the etiology of HaNDL is discussed. Also the role of electroencephalography (EEG) recordings is discussed. Serial EEG recordings showed generalized slowing, frontal intermittent rhythmic delta activity (FIRDA) and symmetric triphasic frontal waves with a dilation lag.

  5. Myonecrosis in Sickle Cell Anemia: Case Study.

    PubMed

    Turaga, Lalita Prabha; Boddu, Prajwal; Kipferl, Steve; Basu, Anupam; Yorath, Martin

    2017-01-30

    BACKGROUND Myonecrosis is one of the more poorly studied, painful manifestations of sickle cell crisis. Medical literature is sparse detailing the manifestations and management of such symptoms. In myonecrosis, red cells containing sickle hemoglobin become rigid, resulting in reduced blood flow and myonecrosis. CASE REPORT We present a case study of a patient in sickle cell crisis with an episode of acute pain and swelling to the intrinsic muscles of the foot as a prominent feature of the crises. Although muscle biopsy is considered the gold standard for the diagnosis of myositis or myonecrosis, a low intensity signal on T1 and high intensity signal on T2 at the affected muscle belly can be as conclusive as imaging studies. In an actively sickling patient any invasive intervention should be avoided as it can result in ischemic necrosis of the tissues, due to interruption of capillary flow in end-arteries. CONCLUSIONS Early recognition is critical in sickle cell disease management, allowing for prompt and aggressive fluid resuscitation which remains a cornerstone in the management of most sickle cell vaso-occlusive crises. In this instance, off loading the extremity and early fluid resuscitation resolved the pain and swelling and prevented myonecrosis.

  6. Hydrodynamics of Low Reynolds Respiratory-type Flows

    NASA Astrophysics Data System (ADS)

    Connor, Erin; True, Aaron; Crimaldi, John

    2017-11-01

    Both aquatic and terrestrial animals inhale surrounding fluid for metabolic and sensory purposes. As organisms inhale and exhale, complex fluid interactions occur both internal and external to the physiological orifice. Using both numerical and experimental approaches, we model an idealized respiratory flow consisting of cyclic inhalation and exhalation through a single cylindrical tube. We investigate the effect of varying Reynolds number (Re) as well as the ratio of the inhalation time to the exhalation time (I:E ratio) for a fixed inhalation volume. The numerical model is used for laminar cases at lower Re, whereas the experimental model permits the study to be extended into higher Reynolds numbers that include transitions to turbulence. We map the spatial distribution of both inhaled and exhaled fluid volumes. By comparing these two maps, we can compute the volume of exhaled fluid that is reingested during the subsequent inhalation. The models of interacting inhalation and exhalation exhibit a rich range of flow behaviors across Re number and I:E ratio. This study builds a foundation for more complex studies of animal respiration that will include more realistic morphologies.

  7. Study of blades inclination influence of gate impeller with a non-Newtonian fluid of Bingham

    NASA Astrophysics Data System (ADS)

    Rahmani, Lakhdar; Seghier, O.; Draoui, B.; Benachour, E.

    2016-03-01

    A large number of chemical operations, biochemical or petrochemical industry is very depending on the rheological fluids nature. In this work, we study the case of highly viscous of viscoplastic fluids in a classical system of agitation: a cylindrical tank with plate bottom without obstacles agitated by gate impeller agitator. We are interested to the laminar, incompressible and isothermal flows. We devote to a numerical approach carried out using an industrial code CFD Fluent 6.3.26 based on the method of finites volumes discretization of Navier - Stokes equations formulated in variables (U.V.P). The threshold of flow related to the viscoplastic behavior is modeled by a theoretical law of Bingham. The results obtained are used to compare between the five configurations suggested of power consumption. We study the influence of inertia by the variation of Reynolds number.

  8. A systems approach to theoretical fluid mechanics: Fundamentals

    NASA Technical Reports Server (NTRS)

    Anyiwo, J. C.

    1978-01-01

    A preliminary application of the underlying principles of the investigator's general system theory to the description and analyses of the fluid flow system is presented. An attempt is made to establish practical models, or elements of the general fluid flow system from the point of view of the general system theory fundamental principles. Results obtained are applied to a simple experimental fluid flow system, as test case, with particular emphasis on the understanding of fluid flow instability, transition and turbulence.

  9. Particle-bearing currents in uniform density and two-layer fluids

    NASA Astrophysics Data System (ADS)

    Sutherland, Bruce R.; Gingras, Murray K.; Knudson, Calla; Steverango, Luke; Surma, Christopher

    2018-02-01

    Lock-release gravity current experiments are performed to examine the evolution of a particle bearing flow that propagates either in a uniform-density fluid or in a two-layer fluid. In all cases, the current is composed of fresh water plus micrometer-scale particles, the ambient fluid is saline, and the current advances initially either over the surface as a hypopycnal current or at the interface of the two-layer fluid as a mesopycnal current. In most cases the tank is tilted so that the ambient fluid becomes deeper with distance from the lock. For hypopycnal currents advancing in a uniform density fluid, the current typically slows as particles rain out of the current. While the loss of particles alone from the current should increase the current's buoyancy and speed, in practice the current's speed decreases because the particles carry with them interstitial fluid from the current. Meanwhile, rather than settling on the sloping bottom of the tank, the particles form a hyperpycnal (turbidity) current that advances until enough particles rain out that the relatively less dense interstitial fluid returns to the surface, carrying some particles back upward. When a hypopycnal current runs over the surface of a two-layer fluid, the particles that rain out temporarily halt their descent as they reach the interface, eventually passing through it and again forming a hyperpycnal current. Dramatically, a mesopycnal current in a two-layer fluid first advances along the interface and then reverses direction as particles rain out below and fresh interstitial fluid rises above.

  10. Pathway from subducting slab to surface for melt and fluids beneath Mount Rainier.

    PubMed

    McGary, R Shane; Evans, Rob L; Wannamaker, Philip E; Elsenbeck, Jimmy; Rondenay, Stéphane

    2014-07-17

    Convergent margin volcanism originates with partial melting, primarily of the upper mantle, into which the subducting slab descends. Melting of this material can occur in one of two ways. The flow induced in the mantle by the slab can result in upwelling and melting through adiabatic decompression. Alternatively, fluids released from the descending slab through dehydration reactions can migrate into the hot mantle wedge, inducing melting by lowering the solidus temperature. The two mechanisms are not mutually exclusive. In either case, the buoyant melts make their way towards the surface to reside in the crust or to be extruded as lava. Here we use magnetotelluric data collected across the central state of Washington, USA, to image the complete pathway for the fluid-melt phase. By incorporating constraints from a collocated seismic study into the magnetotelluric inversion process, we obtain superior constraints on the fluids and melt in a subduction setting. Specifically, we are able to identify and connect fluid release at or near the top of the slab, migration of fluids into the overlying mantle wedge, melting in the wedge, and transport of the melt/fluid phase to a reservoir in the crust beneath Mt Rainier.

  11. Pathway from subducting slab to surface for melt and fluids beneath Mount Rainier

    NASA Astrophysics Data System (ADS)

    McGary, R. Shane; Evans, Rob L.; Wannamaker, Philip E.; Elsenbeck, Jimmy; Rondenay, Stéphane

    2014-07-01

    Convergent margin volcanism originates with partial melting, primarily of the upper mantle, into which the subducting slab descends. Melting of this material can occur in one of two ways. The flow induced in the mantle by the slab can result in upwelling and melting through adiabatic decompression. Alternatively, fluids released from the descending slab through dehydration reactions can migrate into the hot mantle wedge, inducing melting by lowering the solidus temperature. The two mechanisms are not mutually exclusive. In either case, the buoyant melts make their way towards the surface to reside in the crust or to be extruded as lava. Here we use magnetotelluric data collected across the central state of Washington, USA, to image the complete pathway for the fluid-melt phase. By incorporating constraints from a collocated seismic study into the magnetotelluric inversion process, we obtain superior constraints on the fluids and melt in a subduction setting. Specifically, we are able to identify and connect fluid release at or near the top of the slab, migration of fluids into the overlying mantle wedge, melting in the wedge, and transport of the melt/fluid phase to a reservoir in the crust beneath Mt Rainier.

  12. Swimming at low Reynolds number in fluids with odd, or Hall, viscosity.

    PubMed

    Lapa, Matthew F; Hughes, Taylor L

    2014-04-01

    We apply the geometric theory of swimming at low Reynolds number to the study of nearly circular swimmers in two-dimensional fluids with nonvanishing "odd," or Hall, viscosity. The odd viscosity gives an off-diagonal contribution to the fluid stress tensor, which results in a number of striking effects. In particular, we find that a swimmer whose area is changing will experience a torque proportional to the rate of change of the area, with the constant of proportionality given by the coefficient ηo of odd viscosity. After working out the general theory of swimming in fluids with odd viscosity for a class of simple swimmers, we give a number of example swimming strokes which clearly demonstrate the differences between swimming in a fluid with conventional viscosity and a fluid which also has an odd viscosity. We also include a discussion of the extension of the famous Scallop theorem of low Reynolds number swimming to the case where the fluid has a nonzero odd viscosity. A number of more technical results, including a proof of the torque-area relation for swimmers of more general shape, are explained in a set of Appendixes.

  13. Inertial migration of elastic particles in a pressure-driven power-law fluid

    NASA Astrophysics Data System (ADS)

    Bowie, Samuel; Alexeev, Alexander

    2016-11-01

    Using three-dimensional computer simulations, we study the cross-stream migration of deformable particles in a channel filled with a non-Newtonian fluid driven by a pressure gradient. Our numerical approach integrates lattice Boltzmann method and lattice spring method in order to model fluid structural interactions of the elastic particle and the surrounding power fluid in the channel. The particles are modeled as elastic shells filled with a viscous fluid that are initially spherical. We focus on the regimes where the inertial effects cannot be neglected and cause cross-stream drift of particles. We probe the flow with different power law indexes including both the shear thickening and thinning fluids. We also examine migration of particles of with different elasticity and relative size. To isolate the non-Newtonian effects on particle migration, we compare the results with the inertial migration results found in the case where the channel is filled with a simple Newtonian fluid. The results can be useful for applications requiring high throughput separation, sorting, and focusing of both synthetic particles and biological cells in microfluidic devices. Financial support provided by National Science Foundation (NSF) Grant No. CMMI1538161.

  14. Systematics of Alkali Metals in Pore Fluids from Serpentinite Mud Volcanoes: IODP Expedition 366

    NASA Astrophysics Data System (ADS)

    Wheat, C. G.; Ryan, J.; Menzies, C. D.; Price, R. E.; Sissmann, O.

    2017-12-01

    IODP Expedition 366 focused, in part, on the study of geo­chemical cycling, matrix alteration, material and fluid transport, and deep biosphere processes within the subduction channel in the Mariana forearc. This was accomplished through integrated sampling of summit and flank regions of three active serpentinite mud volcanoes (Yinazao (Blue Moon), Asùt Tesoro (Big Blue), and Fantangisña (Celestial) Seamounts). These edifices present a transect of depths to the Pacific Plate, allowing one to characterize thermal, pressure and compositional effects on processes that are associated with the formation of serpentinite mud volcanoes and continued activity below and within them. Previous coring on ODP Legs 125 and 195 at two other serpentinite mud volcanoes (Conical and South Chamorro Seamounts) and piston, gravity, and push cores from several other Mariana serpentinite mud volcanoes add to this transect of sites where deep-sourced material is discharged at the seafloor. Pore waters (149 samples) were squeezed from serpentinite materials to determine the composition of deep-sourced fluid and to assess the character, extent, and effect of diagenetic reactions and mixing with seawater on the flanks of the seamounts as the serpentinite matrix weathers. In addition two Water Sampler Temperature Tool (WSTP) fluid samples were collected within two of the cased boreholes, each with at least 30 m of screened casing that allows formations fluids to discharge into the borehole. Shipboard results for Na and K record marked seamount-to-seamount differences in upwelling summit fluids, and complex systematics in fluids obtained from flank sites. Here we report new shore-based Rb and Cs measurements, two elements that have been used to constrain the temperature of the deep-sourced fluid. Data are consistent with earlier coring and drilling expeditions, resulting in systematic changes with depth (and by inference temperature) to the subduction channel.

  15. Finite-difference method Stokes solver (FDMSS) for 3D pore geometries: Software development, validation and case studies

    NASA Astrophysics Data System (ADS)

    Gerke, Kirill M.; Vasilyev, Roman V.; Khirevich, Siarhei; Collins, Daniel; Karsanina, Marina V.; Sizonenko, Timofey O.; Korost, Dmitry V.; Lamontagne, Sébastien; Mallants, Dirk

    2018-05-01

    Permeability is one of the fundamental properties of porous media and is required for large-scale Darcian fluid flow and mass transport models. Whilst permeability can be measured directly at a range of scales, there are increasing opportunities to evaluate permeability from pore-scale fluid flow simulations. We introduce the free software Finite-Difference Method Stokes Solver (FDMSS) that solves Stokes equation using a finite-difference method (FDM) directly on voxelized 3D pore geometries (i.e. without meshing). Based on explicit convergence studies, validation on sphere packings with analytically known permeabilities, and comparison against lattice-Boltzmann and other published FDM studies, we conclude that FDMSS provides a computationally efficient and accurate basis for single-phase pore-scale flow simulations. By implementing an efficient parallelization and code optimization scheme, permeability inferences can now be made from 3D images of up to 109 voxels using modern desktop computers. Case studies demonstrate the broad applicability of the FDMSS software for both natural and artificial porous media.

  16. Comparison of fluid-fluid interfacial areas measured with X-ray microtomography and interfacial partitioning tracer tests for the same samples: COMPARISON OF FLUID-FLUID INTERFACIAL AREAS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McDonald, Kieran; Carroll, Kenneth C.; Brusseau, Mark L.

    2016-07-01

    Two different methods are currently used for measuring interfacial areas between immiscible fluids within 3-D porous media, high-resolution microtomographic imaging and interfacial partitioning tracer tests (IPTT). Both methods were used in this study to measure nonwetting/wetting interfacial areas for a natural sand. The microtomographic imaging was conducted on the same packed columns that were used for the IPTTs. This is in contrast to prior studies comparing the two methods, for which in all cases different samples were used for the two methods. In addition, the columns were imaged before and after the IPTTs to evaluate the potential impacts of themore » tracer solution on fluid configuration and attendant interfacial area. The interfacial areas measured using IPTT are ~5 times larger than the microtomographic-measured values, which is consistent with previous work. Analysis of the image data revealed no significant impact of the tracer solution on NAPL configuration or interfacial area. Other potential sources of error were evaluated, and all were demonstrated to be insignificant. The disparity in measured interfacial areas between the two methods is attributed to the limitation of the microtomography method to characterize interfacial area associated with microscopic surface roughness due to resolution constraints.« less

  17. Simulating coupled dynamics of a rigid-flexible multibody system and compressible fluid

    NASA Astrophysics Data System (ADS)

    Hu, Wei; Tian, Qiang; Hu, HaiYan

    2018-04-01

    As a subsequent work of previous studies of authors, a new parallel computation approach is proposed to simulate the coupled dynamics of a rigid-flexible multibody system and compressible fluid. In this approach, the smoothed particle hydrodynamics (SPH) method is used to model the compressible fluid, the natural coordinate formulation (NCF) and absolute nodal coordinate formulation (ANCF) are used to model the rigid and flexible bodies, respectively. In order to model the compressible fluid properly and efficiently via SPH method, three measures are taken as follows. The first is to use the Riemann solver to cope with the fluid compressibility, the second is to define virtual particles of SPH to model the dynamic interaction between the fluid and the multibody system, and the third is to impose the boundary conditions of periodical inflow and outflow to reduce the number of SPH particles involved in the computation process. Afterwards, a parallel computation strategy is proposed based on the graphics processing unit (GPU) to detect the neighboring SPH particles and to solve the dynamic equations of SPH particles in order to improve the computation efficiency. Meanwhile, the generalized-alpha algorithm is used to solve the dynamic equations of the multibody system. Finally, four case studies are given to validate the proposed parallel computation approach.

  18. Low serum IGF-1 and increased cytokine levels in tracheal aspirate samples are associated with bronchopulmonary dysplasia.

    PubMed

    Yılmaz, Cansu; Köksal, Nilgün; Özkan, Hilal; Dorum, Bayram Ali; Bağcı, Onur

    2017-01-01

    Yılmaz C, Köksal N, Özkan H, Dorum BA, Bağcı O. Low serum IGF-1 and increased cytokine levels in tracheal aspirate samples are associated with bronchopulmonary dysplasia. Turk J Pediatr 2017; 59: 122-129. Despite developments in the perinatal and neonatal care, bronchopulmonary dysplasia (BPD) is still the most frequently seen long-term complication in preterm infants. The aim of this prospective study is to investigate the association between the development of BPD and serial measurements of IGF-1 levels and their relationship with levels of IGF-1 and cytokine in tracheal aspirate fluids. A total of 40 premature infants, born at a gestational age of ≤ 32 weeks, were enrolled in the study. On postnatal day-1, 3, 7, 21 and 28 serum IGF-1 levels and IGF-1 levels, IL-6, IL-8, IL-10 and TNF-alpha levels in tracheal aspirate fluid samples of intubated cases were examined. Mean gestational age of 40 patients included in the study was 29.41 ± 2.23 weeks, and their mean birth weight was 1,256.85 ± 311.48 g. BPD was detected in 35% of cases. Mean gestational week and birth weight of the cases that developed BPD were 30 ± 3 weeks and 1,150 ± 295 g, respectively. Serum IGF-1 levels on postnatal day-1, 3, 7, 21 and 28 in cases who developed BPD were significantly lower when compared with those without BPD (p < 0.01). Levels of IL-6, IL-8, IL-10, and TNF-alpha in tracheal aspirate samples were significantly higher in cases with BPD compared to those without BPD (p < 0.05). IGF-1 levels in tracheal aspirate fluid samples did not differ significantly based on the presence of BPD (p > 0.05). Severity of BPD was associated with decreased serum IGF-1 levels and increased cytokine levels in tracheal aspirate samples.

  19. Viscous effects on the Rayleigh-Taylor instability with background temperature gradient

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gerashchenko, S.; Livescu, D., E-mail: livescu@lanl.gov

    The growth rate of the compressible Rayleigh-Taylor instability is studied in the presence of a background temperature gradient, Θ, using a normal mode analysis. The effect of Θ variation is examined for three interface types corresponding to the combinations of the viscous properties of the fluids (inviscid-inviscid, viscous-viscous, and viscous-inviscid) at different Atwood numbers, At, and when at least one of the fluids' viscosity is non-zero, as a function of the Grashof number. For the general case, the resulting ordinary differential equations are solved numerically; however, dispersion relations for the growth rate are presented for several limiting cases. An analyticalmore » solution is found for the inviscid-inviscid interface and the corresponding dispersion equation for the growth rate is obtained in the limit of large Θ. For the viscous-inviscid case, a dispersion relation is derived in the incompressible limit and Θ = 0. Compared to Θ = 0 case, the role of Θ < 0 (hotter light fluid) is destabilizing and becomes stabilizing when Θ > 0 (colder light fluid). The most pronounced effect of Θ ≠ 0 is found at low At and/or at large perturbation wavelengths relative to the domain size for all interface types. On the other hand, at small perturbation wavelengths relative to the domain size, the growth rate for the Θ < 0 case exceeds the infinite domain incompressible constant density result. The results are applied to two practical examples, using sets of parameters relevant to Inertial Confinement Fusion coasting stage and solar corona plumes. The role of viscosity on the growth rate reduction is discussed together with highlighting the range of wavenumbers most affected by viscosity. The viscous effects further increase in the presence of background temperature gradient, when the viscosity is temperature dependent.« less

  20. Effect of fluid penetration on tensile failure during fracturing of an open-hole wellbore

    NASA Astrophysics Data System (ADS)

    Zeng, Fanhui; Cheng, Xiaozhao; Guo, Jianchun; Chen, Zhangxin; Tao, Liang; Liu, Xiaohua; Jiang, Qifeng; Xiang, Jianhua

    2018-06-01

    It is widely accepted that a fracture can be induced at a wellbore surface when the fluid pressure overcomes the rock tensile strength. However, few models of this phenomenon account for the fluid penetration effect. A rock is a typical permeable, porous medium, and the transmission of pressure from a wellbore to the surrounding rock temporally and spatially perturbs the effective stresses. In addition, these induced stresses influence the fracture initiation pressure. To gain a better understanding of the penetration effect on the initiation pressure of a permeable formation, a comprehensive formula is presented to study the effects of the in situ stresses, rock mechanical properties, injection rate, rock permeability, fluid viscosity, fluid compressibility and wellbore size on the magnitude of the initiation pressure during fracturing of an open-hole wellbore. In this context, the penetration effect is treated as a consequence of the interaction among these parameters by using Darcy’s law of radial flow. A fully coupled analytical procedure is developed to show how the fracturing fluid infiltrates the rock around the wellbore and considerably reduces the magnitude of the initiation pressure. Moreover, the calculation results are validated by hydraulic fracturing experiments in hydrostone. An exhaustive sensitivity study is performed, indicating that the local fluid pressure induced from a seepage effect strongly influences the fracture evolution. For permeable reservoirs, a low injection rate and a low viscosity of the injected fluid have a significant impact on the fracture initiation pressure. In this case, the Hubbert and Haimson equations to predict the fracture initiation pressure are not valid. The open-hole fracture initiation pressure increases with the fracturing fluid viscosity and fluid compressibility, while it decreases as the rock permeability, injection rate and wellbore size increase.

  1. Flocking from a quantum analogy: spin-orbit coupling in an active fluid

    NASA Astrophysics Data System (ADS)

    Loewe, Benjamin; Souslov, Anton; Goldbart, Paul M.

    2018-01-01

    Systems composed of strongly interacting self-propelled particles can form a spontaneously flowing polar active fluid. The study of the connection between the microscopic dynamics of a single such particle and the macroscopic dynamics of the fluid can yield insights into experimentally realizable active flows, but this connection is well understood in only a few select cases. We introduce a model of self-propelled particles based on an analogy with the motion of electrons that have strong spin-orbit coupling. We find that, within our model, self-propelled particles are subject to an analog of the Heisenberg uncertainty principle that relates translational and rotational noise. Furthermore, by coarse-graining this microscopic model, we establish expressions for the coefficients of the Toner-Tu equations—the hydrodynamic equations that describe an active fluid composed of these ‘active spins.’ The connection between stochastic self-propelled particles and quantum particles with spin may help realize exotic phases of matter using active fluids via analogies with systems composed of strongly correlated electrons.

  2. Unsteady free convection flow of viscous fluids with analytical results by employing time-fractional Caputo-Fabrizio derivative (without singular kernel)

    NASA Astrophysics Data System (ADS)

    Ali Shah, Nehad; Mahsud, Yasir; Ali Zafar, Azhar

    2017-10-01

    This article introduces a theoretical study for unsteady free convection flow of an incompressible viscous fluid. The fluid flows near an isothermal vertical plate. The plate has a translational motion with time-dependent velocity. The equations governing the fluid flow are expressed in fractional differential equations by using a newly defined time-fractional Caputo-Fabrizio derivative without singular kernel. Explicit solutions for velocity, temperature and solute concentration are obtained by applying the Laplace transform technique. As the fractional parameter approaches to one, solutions for the ordinary fluid model are extracted from the general solutions of the fractional model. The results showed that, for the fractional model, the obtained solutions for velocity, temperature and concentration exhibit stationary jumps discontinuity across the plane at t=0 , while the solutions are continuous functions in the case of the ordinary model. Finally, numerical results for flow features at small-time are illustrated through graphs for various pertinent parameters.

  3. Effect of pulse pressure on borehole stability during shear swirling flow vibration cementing.

    PubMed

    Cui, Zhihua; Ai, Chi; Lv, Lei; Yin, Fangxian

    2017-01-01

    The shear swirling flow vibration cementing (SSFVC) technique rotates the downhole eccentric cascade by circulating cementing fluid. It makes the casing eccentrically revolve at high speed around the borehole axis. It produces strong agitation action to the annulus fluid, makes it in the state of shear turbulent flow, and results in the formation of pulse pressure which affects the surrounding rock stress. This study was focused on 1) the calculation of the pulse pressure in an annular turbulent flow field based on the finite volume method, and 2) the analysis of the effect of pulse pressure on borehole stability. On the upside, the pulse pressure is conducive to enhancing the liquidity of the annulus fluid, reducing the fluid gel strength, and preventing the formation of fluid from channeling. But greater pulse pressure may cause lost circulation and even formation fracturing. Therefore, in order to ensure smooth cementing during SSFVC, the effect of pulse pressure should be considered when cementing design.

  4. Surveillance of Ocular Parameters and Visual Function in Bed Rest Subjects

    NASA Technical Reports Server (NTRS)

    Cromwell, Ronita L.

    2011-01-01

    Recent visual changes in astronauts have raised concern about ocular health during long duration spaceflight. Seven cases have been documented in astronauts who spent 6 months aboard the International Space Station. These astronauts were male ranging in age from 45 to 55 years old. All astronauts exhibited pre- to post flight refractive changes. Decreased intraocular pressure (IOP) post flight was observed in 3 cases. Fundoscopic exams revealed post flight findings of choroidal folds in 4 cases, optic disc edema in 5 cases and the presence of cotton wool spots in 3 cases. Optical coherence tomography (OCT) confirmed findings of choroidal folds and disc edema, and also documented retinal nerve fiber layer thickening (5 cases). Findings from MRI examinations showed posterior globe flattening (5 cases), optic nerve sheath distention (6 cases) and torturous optic nerves (2 cases). Of the 7 cases, intracranial pressure was measured on 4 astronauts. These 4 showed elevated ICP post-flight that remained elevated for as long as 19 months in one case. While the etiology remains unknown, hypotheses speculate that venous insufficiency or hypertension in the brain caused by cephalad fluid shifts during spaceflight are possible mechanisms for ocular changes seen in astronauts. Head-down tilt bed rest is a spaceflight analog that induces cephalad fluid shifts. This study is designed to provide ocular monitoring of bed rest subjects and determine whether clinically relevant changes are found. Ocular Changes

  5. The Inertial Coefficients of an Airship in a Frictionless Fluid

    NASA Technical Reports Server (NTRS)

    Bateman, H

    1924-01-01

    This report deals with the investigation of the apparent inertia of an airship hull. The exact solution of the aerodynamical problem has been studied for hulls of various shapes and special attention has been given to the case of an ellipsoidal hull. In order that the results for this last case may be readily adapted to other cases, they are expressed in terms of the area and perimeter of the largest cross section perpendicular to the direction motion by means of a formula involving a coefficient K which varies only slowly when the shape of the hull is changed, being 0.637 for a circular or elliptic disk, 0.5 for a sphere, and about 0.25 for a spheroid of fineness ratio 7. For rough purposes it is sufficient to employ the coefficients, originally found for ellipsoids, for hulls otherwise shaped. When more exact values of the inertia are needed, estimates may be based on a study of the way in which K varies with different characteristics and for such a study the new coefficient possesses some advantage over one which is defined with reference to the volume of fluid displaced. The case of rotation of an airship hull has been investigated also and a coefficient has been defined with the same advantages as the corresponding coefficient for rectilinear motion.

  6. Chlamydial infection preceding the development of rheumatoid arthritis: a brief report.

    PubMed

    Jolly, Meenakshi; Curran, J J

    2004-10-01

    Chlamydia trachomatis-triggered reactive arthritis is a well-documented entity that has been extensively described. We do not have a clear understanding about the inflammatory oligoarthritis associated with the presence of this organism. It is rarely cultured from the synovial fluid, but is usually detectable by molecular biological techniques. Typically, Chlamydia trachomatis causes a sterile but inflammatory oligoarthritis. We report an unusual case of inflammatory monoarthritis in a young woman in whom Chlamydia was isolated from the synovial fluid. This is the first case of documented isolation of Chlamydia from synovial fluid, which subsequently was diagnosed as rheumatoid arthritis.

  7. Liquid metal pump for nuclear reactors

    DOEpatents

    Allen, H.G.; Maloney, J.R.

    1975-10-01

    A pump for use in pumping high temperature liquids at high pressures, particularly liquid metals used to cool nuclear reactors is described. It is of the type in which the rotor is submerged in a sump but is fed by an inlet duct which bypasses the sump. A chamber, kept full of fluid, surrounds the pump casing into which fluid is bled from the pump discharge and from which fluid is fed to the rotor bearings and hence to the sump. This equalizes pressure inside and outside the pump casing and reduces or eliminates the thermal shock to the bearings and sump tank.

  8. PERFORMANCE GOALS CASE STUDY: ELIZABETH CITY, NC

    EPA Science Inventory

    Permeable reactive barriers (PRB's) are an emerging, alternative in-situ approach for remediating groundwater contamination that combine subsurface fluid flow management with a passive chemical treatment zone. The few pilot and commercial installations which have been implemented...

  9. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Greener, J.M.; Trimble, G.E.; Singer, G.M.

    This paper describes the Opon Gas Field development drilling case history in the Middle Magdalena Basin of north-central Colombia, South America. World class levels of drilling fluid and cementing densities in excess of 22.0 ppg were required to control the extreme pressures encountered. A continuous improvement process is detailed in regard to casing, drilling fluid, cement and related drilling mechanics programs in a severely pressured and environmentally sensitive operation.

  10. 75 FR 20787 - Airworthiness Directives; Bombardier, Inc. Model DHC-8-400, -401, and -402 Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-21

    ... increased fluid flow within the No. 1 hydraulic system. In one case, the hydraulic system control logic did... (PTU) control logic, including the provision of automatic PTU shutdown in the event of loss of fluid in... one case, the hydraulic system control logic did not shut down the PTU and the overspeed condition...

  11. Numerical Modeling of Three-Dimensional Fluid Flow with Phase Change

    NASA Technical Reports Server (NTRS)

    Esmaeeli, Asghar; Arpaci, Vedat

    1999-01-01

    We present a numerical method to compute phase change dynamics of three-dimensional deformable bubbles. The full Navier-Stokes and energy equations are solved for both phases by a front tracking/finite difference technique. The fluid boundary is explicitly tracked by discrete points that are connected by triangular elements to form a front that is used to keep the stratification of material properties sharp and to calculate the interfacial source terms. Two simulations are presented to show robustness of the method in handling complex phase boundaries. In the first case, growth of a vapor bubble in zero gravity is studied where large volume increase of the bubble is managed by adaptively increasing the front resolution. In the second case, growth of a bubble under high gravity is studied where indentation at the rear of the bubble results in a region of large curvature which challenges the front tracking in three dimensions.

  12. The growth and breakdown of a vortex-pair in a stably stratified fluid

    NASA Astrophysics Data System (ADS)

    Advaith, S.; Tinaikar, Aashay; Manu, K. V.; Basu, Saptarshi

    2017-11-01

    Vortex interaction with density stratification is ubiquitous in nature and applied to various engineering applications. Present study have characterized the spatial and temporal dynamics of the interaction between a vortex and a density stratified interface. The present work is prompted by our research on single tank Thermal Energy Storage (TES) system used in concentrated solar power (CSP) plants where hot and cold fluids are separated by means of density stratification. Rigorous qualitative (High speed Shadowgraph) and quantitative (high speed PIV) studies enable us to have great understanding about vortex formation, propagation, interaction dynamics with density stratified interface, resulted plume characteristics and so on. We have categorized this interaction phenomena in to three different cases based on its nature as non-penetrative, partial penetrative and extensively penetrative. Along with that we have proposed a regime map consisting non-dimensional parameters like Reynolds, Richardson and Atwood numbers which predicts the occurrence above mentioned cases.

  13. Retinal damage caused by air-fluid exchange during pars plana vitrectomy.

    PubMed

    Yang, Sam S; McDonald, H Richard; Everett, A I; Johnson, Robert N; Jumper, J Michael; Fu, Arthur D

    2006-03-01

    To report two cases of retinal damage associated with air infusion during pars plana vitrectomy. Observational case report. The authors reviewed the course of two patients who had retinal damage during par plana vitrectomy and air-fluid exchange for the treatment of macular hole and optic pit-related macular detachment, respectively. The intraoperative observations, postoperative course, and outcomes were reported. As a result of high air infusion flow during air-fluid exchange, retinal damage was created in the area contralateral to the infusion port. In Case 1, an oval area of whitening was noted on the first postoperative day. This area subsequently developed into a large retinal break associated with retinal detachment. In the second case, retinal whitening was noted intraoperatively. This region of pallor resolved quickly during the early postoperative period but resulted in a corresponding inferotemporal visual field defect. High infusion flow during air-fluid exchange in eyes undergoing vitrectomy surgery may result in significant retinal damage. This pressure-induced trauma initially causes retinal whitening that may be seen intraoperatively or during the early postoperative period. The region of damaged retina may develop a retinal break and detachment or a corresponding visual field defect.

  14. Sharp Injury and Exposure to Blood and Body Fluids among Health Care Workers in Health Care Centers of Eastern Ethiopia.

    PubMed

    Alemayehu, T; Worku, A; Assefa, N

    2016-07-01

    Health care workers are facing certain occupational hazards because of sharp injury and exposure to human blood and body fluids as a result of handling wastes. Though much attention is paid for the protection of these workers, the number of exposures and injuries do not show a sign of decline from time to time. To examine the occurrence of sharp injury and exposure to blood and body fluids in health care workers in health care centers in Ethiopia. In a case-control study, a randomly selected sample of 65 health facilities with 391 cases and 429 controls were studied. Data were collected through a self-administered questionnaire. Detailed analysis of exposure among the health care workers was done by logistic regression analysis with generalized estimating equations model to control correlation effects of responses within the cluster of health facilities. The number of health care workers who got sharp injury was 217 (26.5%). 296 (36.1%) had exposure to blood and body fluids. Working at Harari region (adjusted OR 0.44, 95% CI 0.26 to 0.75) and East Hararghea (adjusted OR 0.61, 95% CI 0.40 to 0.94), being male (adjusted OR 0.56, 95% CI 0.44 to 0.91), and a being nurse (adjusted OR 0.188, 95% CI 0.06 to 0.63) were independent risk factors of the exposure. Regardless of the anticipated low self-reporting for exposure status, the number of health care workers reported having sharp injury and exposure to blood and body fluids was high. Such high exposures indicate that health care workers are at high risk of acquiring blood-borne viral infections such as hepatitis B, hepatitis C, and HIV.

  15. Fluid collection after partial pancreatectomy: EUS drainage and long-term follow-up.

    PubMed

    Caillol, Fabrice; Godat, Sebastien; Turrini, Olivier; Zemmour, Christophe; Bories, Erwan; Pesenti, Christian; Ratone, Jean Phillippe; Ewald, Jacques; Delpero, Jean Robert; Giovannini, Marc

    2018-03-29

    Postoperative fluid collection due to pancreatic leak is the most frequent complication after pancreatic surgery. Endoscopic ultrasound (EUS)-guided drainage of post-pancreatic surgery fluid collection is the gold standard procedure; however, data on outcomes of this procedure are limited. The primary endpoint of our study was relapse over longterm followup, and the secondary endpoint was the efficiency and safety of EUS-guided drainage of post-pancreatic surgery fluid collection. This retrospective study was conducted at a single center from December 2008 to April 2016. Global morbidity was defined as the occurrence of an event involving additional endoscopic procedures, hospitalization, or interventional radiologic or surgical procedures. EUS-guided drainage was considered a clinical failure if surgery was required to treat a relapse after stent removal. Fortyone patients were included. The technical success rate was 100%. Drainage was considered a clinical success in 93% (39/41) of cases. Additionally, 19 (46%) complications were identified as global morbidity. The duration between surgery and EUS-guided drainage was not a significantly related factor for morbidity rate (P = 0.8); however, bleeding due to arterial injuries (splenic artery and gastroduodenal artery) from salvage drainage procedures occurred within 25 days following the initial surgery. There was no difference in survival between patients with and without complications. No relapse was reported during the followup (median: 44.75 months; range: 29.24 to 65.74 months). EUSguided drainage for post-pancreatic surgery fluid collection was efficient with no relapse during longterm followup. Morbidity rate was independent of the duration between the initial surgery and EUS-guided drainage; however, bleeding risk was likely more important in cases of early drainage.

  16. Linear instabilities near the DIII-D edge simulated in fluid models

    NASA Astrophysics Data System (ADS)

    Bass, Eric; Holland, Christopher

    2017-10-01

    The linear instability spectrum is reported near the DIII-D edge (within the separatrix) for L-mode and H-mode shots using the new eigenvalue solver FluTES (Fluid Toroidal Eigenvalue Solver). FluTES circumvents difficulties with convergence to clean linear eigenmodes (required for diagnosis of nonlinear simulations in codes such as BOUT++) often encountered with fluid initial-value solvers. FluTES is well-verified in analytic cases and against a BOUT++/ELITE benchmark toroidal case. We report results for both a 3-field, one-fluid model (the well-known ``elm-pb'' model) and a 5-field, two-fluid model. For the peeling-ballooning-dominated H-mode, the two solutions are qualitatively the same. In the driftwave-dominated L-mode edge, only the two-fluid solution gives robust instabilities which occur primarily at n > 50 . FluTES is optimized for this regime (near-flutelike limit, toroidally spectral). Cross-separatrix, coupled fluid and drift instabilities may play a role in explaining the gyrokinetic L-mode edge transport shortfall. Extension of FluTES into the open-field-line region is underway. Prepared by UCSD under Contract Number DE-FG02-06ER54871.

  17. Combined effects of magnetic field and partial slip on obliquely striking rheological fluid over a stretching surface

    NASA Astrophysics Data System (ADS)

    Nadeem, S.; Mehmood, Rashid; Akbar, Noreen Sher

    2015-03-01

    This study explores the collective effects of partial slip and transverse magnetic field on an oblique stagnation point flow of a rheological fluid. The prevailing momentum equations are designed by manipulating Casson fluid model. By applying the suitable similarity transformations, the governing system of equations is being transformed into coupled nonlinear ordinary differential equations. The resulting system is handled numerically through midpoint integration scheme together with Richardson's extrapolation. It is found that both normal and tangential velocity profiles decreases with an increase in magnetic field as well as slip parameter. Streamlines pattern are presented to study the actual impact of slip mechanism and magnetic field on the oblique flow. A suitable comparison with the previous literature is also provided to confirm the accuracy of present results for the limiting case.

  18. Multiphase numerical analysis of heat pipe with different working fluids for solar applications

    NASA Astrophysics Data System (ADS)

    Aswath, S.; Netaji Naidu, V. H.; Padmanathan, P.; Raja Sekhar, Y.

    2017-11-01

    Energy crisis is a prognosis predicted in many cases with the indiscriminate encroachment of conventional energy sources for applications on a massive scale. This prediction, further emboldened by the marked surge in global average temperatures, attributed to climate change and global warming, the necessity to conserve the environment and explore alternate sources of energy is at an all-time high. Despite being among the lead candidates for such sources, solar energy is utilized far from its vast potential possibilities due to predominant economic constraints. Even while there is a growing need for solar panels at more affordable rates, the other options to harness better out of sun’s energy is to optimize and improvise existing technology. One such technology is the heat pipe used in Evacuated Tube Collectors (ETC). The applications of heat pipe have been gaining momentum in various fields since its inception and substantial volumes of research have explored optimizing and improving the technology which is proving effective in heat recovery and heat transfer better than conventional systems. This paper carries out a computational analysis on a comparative simulation between two working fluids within heat pipe of same geometry. It further endeavors to study the multiphase transitions within the heat pipe. The work is carried out using ANSYS Fluent with inputs taken from solar data for the location of Vellore, Tamil Nadu. A wickless, gravity-assisted heat pipe (GAHP) is taken for the simulation. Water and ammonia are used as the working fluids for comparative multiphase analysis to arrive at the difference in heat transfer at the condenser section. It is demonstrated that a heat pipe ETC with ammonia as working fluid showed higher heat exchange (temperature difference) as against that of water as working fluid. The multiphase model taken aided in study of phase transitions within both cases and supported the result of ammonia as fluid being a better candidate.

  19. WIDEFIELD SPECTRAL-DOMAIN OPTICAL COHERENCE TOMOGRAPHY IMAGING OF PERIPHERAL ROUND RETINAL HOLES WITH OR WITHOUT RETINAL DETACHMENT.

    PubMed

    Casswell, Edward J; Abou Ltaif, Sleiman; Carr, Thomas; Keane, Pearse A; Charteris, David G; Wickham, Louisa

    2018-03-02

    To describe the widefield spectral-domain optical coherence tomography features of peripheral round retinal holes, with or without associated retinal detachment (RD). Retrospective, observational study of 28 eyes with peripheral round retinal holes, with and without RD. Patients underwent imaging with a widefield 50-degree spectral-domain optical coherence tomography (Heidelberg Engineering, Germany) and Optos ultra-widefield imaging systems (Optos, United Kingdom). Vitreous attachment at the site of the retinal hole was detected in 27/28 (96.4%) cases. Cases were split into three groups: RHs with RD (n = 12); RHs with subretinal fluid (n = 5), and flat RHs (n = 11), with minimal or no subretinal fluid. 91.6% retinal holes associated with subretinal fluid or RD had vitreous attachment at the site of the hole. Eighty percent had vitreous attachment at both edges of the retinal hole, in a U-shape configuration, which appeared to exert traction. By contrast, flat retinal holes had visible vitreous attachment only at one edge of the retinal hole in 45.4%. Vitreous attachment was commonly seen at the site of round retinal holes. Vitreous attachment at both edges of the retinal hole in a U-shape configuration was more commonly seen at holes associated with subretinal fluid or RD.

  20. Tracking interface and common curve dynamics for two-fluid flow in porous media

    DOE PAGES

    Mcclure, James E.; Miller, Cass T.; Gray, W. G.; ...

    2016-04-29

    Pore-scale studies of multiphase flow in porous medium systems can be used to understand transport mechanisms and quantitatively determine closure relations that better incorporate microscale physics into macroscale models. Multiphase flow simulators constructed using the lattice Boltzmann method provide a means to conduct such studies, including both the equilibrium and dynamic aspects. Moving, storing, and analyzing the large state space presents a computational challenge when highly-resolved models are applied. We present an approach to simulate multiphase flow processes in which in-situ analysis is applied to track multiphase flow dynamics at high temporal resolution. We compute a comprehensive set of measuresmore » of the phase distributions and the system dynamics, which can be used to aid fundamental understanding and inform closure relations for macroscale models. The measures computed include microscale point representations and macroscale averages of fluid saturations, the pressure and velocity of the fluid phases, interfacial areas, interfacial curvatures, interface and common curve velocities, interfacial orientation tensors, phase velocities and the contact angle between the fluid-fluid interface and the solid surface. Test cases are studied to validate the approach and illustrate how measures of system state can be obtained and used to inform macroscopic theory.« less

  1. Analysis of Variability in Intraoperative Fluid Administration for Colorectal Surgery: An Argument for Goal-Directed Fluid Therapy.

    PubMed

    Quinn, Timothy D; Brovman, Ethan Y; Urman, Richard D

    2017-09-01

    Fluid therapy in the perioperative period varies greatly between anesthesia providers and may have a negative impact on surgical outcomes. We conducted a retrospective analysis of 705 elective colorectal cases consisting of colectomies, ileocolic resections, and low anterior resections at an academic institution from January 1, 2010 to May 29, 2015, collected by our electronic medical record before implementation of Enhanced Recovery After Surgery (ERAS ® ) pathways. The mean for total crystalloid administration was 2578 mL with a standard deviation (SD) that was approximately 50% of the mean value. A combination of both normal saline and lactated Ringer's solution was used in almost all cases without a clear rationale for fluid choice. Fluid administered to patients was disproportional to measured intraoperative fluid losses (estimated blood loss and urine output) by a factor of 10. The average rate of fluid given was 1050 mL/h with an SD of nearly the same amount (951 mL). There was a variability of over 67% in total crystalloid administered based on both ideal body weight and total body weight. We found that a wide variability in the amount and type of fluid therapy administered existed at our institution before implementation of a colorectal ERAS pathway or routine use of goal-directed fluid therapy (GDFT). ERAS pathways with GDFT protocols could lead to more rational and consistent fluid therapy leading to improved outcomes.

  2. Study of grid independence of finite element method on MHD free convective casson fluid flow with slip effect

    NASA Astrophysics Data System (ADS)

    Raju, R. Srinivasa; Ramesh, K.

    2018-05-01

    The purpose of this work is to study the grid independence of finite element method on MHD Casson fluid flow past a vertically inclined plate filled in a porous medium in presence of chemical reaction, heat absorption, an external magnetic field and slip effect has been investigated. For this study of grid independence, a mathematical model is developed and analyzed by using appropriate mathematical technique, called finite element method. Grid study discussed with the help of numerical values of velocity, temperature and concentration profiles in tabular form. avourable comparisons with previously published work on various special cases of the problem are obtained.

  3. Self-induced seismicity due to fluid circulation along faults

    NASA Astrophysics Data System (ADS)

    Aochi, Hideo; Poisson, Blanche; Toussaint, Renaud; Rachez, Xavier; Schmittbuhl, Jean

    2014-03-01

    In this paper, we develop a system of equations describing fluid migration, fault rheology, fault thickness evolution and shear rupture during a seismic cycle, triggered either by tectonic loading or by fluid injection. Assuming that the phenomena predominantly take place on a single fault described as a finite permeable zone of variable width, we are able to project the equations within the volumetric fault core onto the 2-D fault interface. From the basis of this `fault lubrication approximation', we simulate the evolution of seismicity when fluid is injected at one point along the fault to model-induced seismicity during an injection test in a borehole that intercepts the fault. We perform several parametric studies to understand the basic behaviour of the system. Fluid transmissivity and fault rheology are key elements. The simulated seismicity generally tends to rapidly evolve after triggering, independently of the injection history and end when the stationary path of fluid flow is established at the outer boundary of the model. This self-induced seismicity takes place in the case where shear rupturing on a planar fault becomes dominant over the fluid migration process. On the contrary, if healing processes take place, so that the fluid mass is trapped along the fault, rupturing occurs continuously during the injection period. Seismicity and fluid migration are strongly influenced by the injection rate and the heterogeneity.

  4. Cochlear fluid space dimensions for six species derived from reconstructions of three-dimensional magnetic resonance images.

    PubMed

    Thorne, M; Salt, A N; DeMott, J E; Henson, M M; Henson, O W; Gewalt, S L

    1999-10-01

    To establish the dimensions and volumes of the cochlear fluid spaces. Fluid space volumes, lengths, and cross-sectional areas were derived for the cochleas from six species: human, guinea pig, bat, rat, mouse, and gerbil. Three-dimensional reconstructions of the fluid spaces were made from magnetic resonance microscopy (MRM) images. Consecutive serial slices composed of isotropic voxels (25 microm3) representing the entire volume of fixed, isolated cochleas were obtained. The boundaries delineating the fluid spaces, including Reissner's membrane, were resolved for all specimens, except for the human, in which Reissner's membrane was not consistently resolved. Three-dimensional reconstructions of the endolymphatic and perilymphatic fluid spaces were generated. Fluid space length and variation of cross-sectional area with distance were derived by an algorithm that followed the midpoint of the space along the length of the spiral. The total volume of each fluid space was derived from a voxel count for each specimen. Length, volume, and cross-sectional areas are provided for six species. In all cases, the length of the endolymphatic fluid space was consistently longer than that of either perilymphatic scala, primarily as a result of a greater radius of curvature. For guinea pig specimens, the measured volumes of the fluid spaces were considerably lower than those suggested by previous reports based on histological data. The quantification of cochlear fluid spaces provided by this study will enable the more accurate calculation of drug and other solute movements in fluids of the inner ear during experimental or clinical manipulations.

  5. Forensic differentiation between peripheral and menstrual blood in cases of alleged sexual assault-validating an immunochromatographic multiplex assay for simultaneous detection of human hemoglobin and D-dimer.

    PubMed

    Holtkötter, Hannah; Dias Filho, Claudemir Rodrigues; Schwender, Kristina; Stadler, Christian; Vennemann, Marielle; Pacheco, Ana Claudia; Roca, Gabriela

    2018-05-01

    Sexual assault is a serious offense and identification of body fluids originating from sexual activity has been a crucial aspect of forensic investigations for a long time. While reliable tests for the detection of semen and saliva have been successfully implemented into forensic laboratories, the detection of other body fluids, such as vaginal or menstrual fluid, is more challenging. Especially, the discrimination between peripheral and menstrual blood can be highly relevant for police investigations because it provides potential evidence regarding the issue of consent. We report the forensic validation of an immunochromatographic test that allows for such discrimination in forensic stains, the SERATEC PMB test, and its performance on real casework samples. The PMB test is a duplex test combining human hemoglobin and D-dimer detection and was developed for the identification of blood and menstrual fluid, both at the crime scene and in the laboratory. The results of this study showed that the duplex D-dimer/hemoglobin assay reliably detects the presence of human hemoglobin and identifies samples containing menstrual fluid by detecting the presence of D-dimers. The method distinguished between menstrual and peripheral blood in a swab from a historical artifact and in real casework samples of alleged sexual assaults. Results show that the development of the new duplex test is a substantial progress towards analyzing and interpreting evidence from sexual assault cases.

  6. A self-consistent treatment of a fluid in an external potential

    NASA Astrophysics Data System (ADS)

    Boudh-Hir, M.-E.

    A simple fluid of particles near a repulsive structureless wall can be approximated by an identical fluid interacting with an ideal wall. The expansion in powers of the Andersen-Weeks-Chandler (AWC) blip function is used. Lado's criterion, which permits a self-consistent approximation, is extended to the surface case.

  7. Fluid Structure Interaction in a Cold Flow Test and Transient CFD Analysis of Out-of-Round Nozzles

    NASA Technical Reports Server (NTRS)

    Ruf, Joseph; Brown, Andrew; McDaniels, David; Wang, Ten-See

    2010-01-01

    This viewgraph presentation describes two nozzle fluid flow interactions. They include: 1) Cold flow nozzle tests with fluid-structure interaction at nozzle separated flow; and 2) CFD analysis for nozzle flow and side loads of nozzle extensions with various out-of-round cases.

  8. Self-filling and self-purging apparatus for detecting spontaneous radiation from substances in fluids

    DOEpatents

    Larson, I. Lauren; Chiles, Marion M.; Miller, V. Clint

    1993-01-01

    Disclosed herein is a radiation detector providing for the in situ automatic sampling of fluids containing substances emitting radiation, especially Cerenkov radiation. The detector permits sampling within well casings and is self-purging such that no additional provisions must be established for the storage and disposal of contaminated fluids.

  9. Asymptotic Laws of Thermovibrational Convecton in a Horizontal Fluid Layer

    NASA Astrophysics Data System (ADS)

    Smorodin, B. L.; Myznikova, B. I.; Keller, I. O.

    2017-02-01

    Theoretical study of convective instability is applied to a horizontal layer of incompressible single-component fluid subjected to the uniform steady gravity, longitudinal vibrations of arbitrary frequency and initial temperature difference. The mathematical model of thermovibrational convection has the form of initial boundary value problem for the Oberbeck-Boussinesq system of equations. The problems are solved using different simulation strategies, like the method of averaging, method of multiple scales, Galerkin approach, Wentzel-Kramers-Brillouin method and Floquet technique. The numerical analysis has shown that the effect of vibrations on the stability threshold is complex: vibrations can either stabilize or destabilize the basic state depending on values of the parameters. The influence of the Prandtl number on the instability thresholds is investigated. The asymptotic behaviour of critical values of the parameters is studied in two limiting cases: (i) small amplitude and (ii) low frequency of vibration. In case (i), the instability is due to the influence of thermovibrational mechanism on the classical Rayleigh-Benard convective instability. In case (ii), the nature of the instability is related to the instability of oscillating counter-streams with a cubic profile.

  10. The Effect of Loading Rate on Hydraulic Fracturing in Synthetic Granite - a Discrete Element Study

    NASA Astrophysics Data System (ADS)

    Tomac, I.; Gutierrez, M.

    2015-12-01

    Hydraulic fracture initiation and propagation from a borehole in hard synthetic rock is modeled using the two dimensional Discrete Element Method (DEM). DEM uses previously established procedure for modeling the strength and deformation parameters of quasi-brittle rocks with the Bonded Particle Model (Itasca, 2004). A series of simulations of laboratory tests on granite in DEM serve as a reference for synthetic rock behavior. Fracturing is enabled by breaking parallel bonds between DEM particles as a result of the local stress state. Subsequent bond breakage induces fracture propagation during a time-stepping procedure. Hydraulic fracturing occurs when pressurized fluid induces hoop stresses around the wellbore which cause rock fracturing and serves for geo-reservoir permeability enhancement in oil, gas and geothermal industries. In DEM, a network of fluid pipes and reservoirs is used for mathematical calculation of fluid flow through narrow channels between DEM particles, where the hydro-mechanical coupling is fully enabled. The fluid flow calculation is superimposed with DEM stress-strain calculation at each time step. As a result, the fluid pressures during borehole pressurization in hydraulic fracturing, as well as, during the fracture propagation from the borehole, can be simulated. The objective of this study is to investigate numerically a hypothesis that fluid pressurization rate, or the fluid flow rate, influences upon character, shape and velocity of fracture propagation in rock. The second objective is to better understand and define constraints which are important for successful fracture propagation in quasi-brittle rock from the perspective of flow rate, fluid density, viscosity and compressibility relative to the rock physical properties. Results from this study indicate that not only too high fluid flow rates cause fracture arrest and multiple fracture branching from the borehole, but also that the relative compressibility of fracturing fluid and rock plays a significant role in fracture propagation velocity. Fluid viscosity effects are similar to the loading rate effects, because in both cases the rapid buildup of the pressure in the wellbore in absence of the inflow of the fluid into initiated fracture causes induction of multiple simultaneous fracture branches at the wellbore wall.

  11. Criteria for Analyzing the Quality Estimate shake using two different impellers, “Rushton Turbine” and “PBT 45”

    NASA Astrophysics Data System (ADS)

    Oliveira, E. C. M.; Silva, M. O. M.; Nunhez, J. R.; Ribeiro, e. L. C. L. J.

    2016-08-01

    The Computational Fluid Dynamics (CFD) is used to numerically simulate the behavior of fluid flow, and all the laws that rule the study of fluids, both the energy and mass transfer, chemical reactions, hydraulic behavior, and other applications. Among these innumerable applications, the local behavior of a mixing tank can be estimated using the CFD techniques. In order to follow-up studies in the literature giving them increased credibility, this project aimed to determine whether both the scheduling Potency/Volume and Torque/Volume maintain the necessary level of agitation in the mix tank to extrapolate the volume 10 times and 100 times, using an axial impeller blades inclined at 45 degrees type (PBT 45), and a radial impeller (Rushton turbine) with the use of the CFD. With the results, was analyzed if a criterion is superior to the other in terms of maintaining the level of agitation in scheduling. The case study made it possible to achieve the main objective, deepen studies in Computational Fluid Dynamics. Therefore, managed to the largest domain in tools offered by CFX-ANSYS 14.0 software, allowing future work to be conducted.

  12. Influence of non-integer-order derivatives on unsteady unidirectional motions of an Oldroyd-B fluid with generalized boundary conditions

    NASA Astrophysics Data System (ADS)

    Zafar, A. A.; Riaz, M. B.; Shah, N. A.; Imran, M. A.

    2018-03-01

    The objective of this article is to study some unsteady Couette flows of an Oldroyd-B fluid with non-integer derivatives. The fluid fills an annular region of two infinite co-axial circular cylinders. Flows are due to the motion of the outer cylinder, that rotates about its axis with an arbitrary time-dependent velocity while the inner cylinder is held fixed. Closed form solutions of dimensionless velocity field and tangential tension are obtained by means of the finite Hankel transform and the theory of Laplace transform for fractional calculus. Several results in the literature including the rotational flows through an infinite cylinder can be obtained as limiting cases of our general solutions. Finally, the control of the fractional framework on the dynamics of fluid is analyzed by numerical simulations and graphical illustrations.

  13. Soft particles at a fluid interface

    NASA Astrophysics Data System (ADS)

    Mehrabian, Hadi; Harting, Jens; Snoeijer, Jacco H.

    2015-11-01

    Particles added to a fluid interface can be used as a surface stabilizer in the food, oil and cosmetic industries. As an alternative to rigid particles, it is promising to consider highly deformable particles that can adapt their conformation at the interface. In this study, we compute the shapes of soft elastic particles using molecular dynamics simulations of a cross-linked polymer gel, complemented by continuum calculations based on the linear elasticity. It is shown that the particle shape is not only affected by the Young's modulus of the particle, but also strongly depends on whether the gel is partially or completely wetting the fluid interface. We find that the molecular simulations for the partially wetting case are very accurately described by the continuum theory. By contrast, when the gel is completely wetting the fluid interface the linear theory breaks down and we reveal that molecular details have a strong influence on the equilibrium shape.

  14. Cooling beyond the boundary value in supercritical fluids under vibration

    NASA Astrophysics Data System (ADS)

    Sharma, D.; Erriguible, A.; Amiroudine, S.

    2017-12-01

    Supercritical fluids when subjected to simultaneous quench and vibration have been known to cause various intriguing flow phenomena and instabilities depending on the relative direction of temperature gradient and vibration. Here we describe a surprising and interesting phenomenon wherein temperature in the fluid falls below the imposed boundary value when the walls are quenched and the direction of vibration is normal to the temperature gradient. We define these regions in the fluid as sink zones, because they act like sink for heat within the fluid domain. The formation of these zones is first explained using a one-dimensional (1D) analysis with acceleration in constant direction. Subsequently, the effect of various boundary conditions and the relative direction of the temperature gradient to acceleration are analyzed, highlighting the necessary conditions for the formation of sink zones. It is found that the effect of high compressibility and the action of self-weight (due to high acceleration) causes the temperature to change in the bulk besides the usual action of piston effect. This subsequently affects the overall temperature profile thereby leading to the formation of sink zones. Though the examined 1D cases differ from the current two-dimensional (2D) cases, owing to the direction of acceleration being normal as compared to parallel in case of former, the explanations pertaining to 1D cases are judiciously utilized to elucidate the formation of sink zones in 2D supercritical fluids subjected to thermal quench and vibrational acceleration. The appearance of sink zones is found to be dependent on several factors such as proximity to the critical point and acceleration. A surface three-dimensional plot illustrating the effect of these parameters on onset time of sink zones is presented to further substantiate these arguments.

  15. Fluid-Structure Interaction Simulation of Prosthetic Aortic Valves: Comparison between Immersed Boundary and Arbitrary Lagrangian-Eulerian Techniques for the Mesh Representation

    PubMed Central

    Iannaccone, Francesco; Degroote, Joris; Vierendeels, Jan; Segers, Patrick

    2016-01-01

    In recent years the role of FSI (fluid-structure interaction) simulations in the analysis of the fluid-mechanics of heart valves is becoming more and more important, being able to capture the interaction between the blood and both the surrounding biological tissues and the valve itself. When setting up an FSI simulation, several choices have to be made to select the most suitable approach for the case of interest: in particular, to simulate flexible leaflet cardiac valves, the type of discretization of the fluid domain is crucial, which can be described with an ALE (Arbitrary Lagrangian-Eulerian) or an Eulerian formulation. The majority of the reported 3D heart valve FSI simulations are performed with the Eulerian formulation, allowing for large deformations of the domains without compromising the quality of the fluid grid. Nevertheless, it is known that the ALE-FSI approach guarantees more accurate results at the interface between the solid and the fluid. The goal of this paper is to describe the same aortic valve model in the two cases, comparing the performances of an ALE-based FSI solution and an Eulerian-based FSI approach. After a first simplified 2D case, the aortic geometry was considered in a full 3D set-up. The model was kept as similar as possible in the two settings, to better compare the simulations’ outcomes. Although for the 2D case the differences were unsubstantial, in our experience the performance of a full 3D ALE-FSI simulation was significantly limited by the technical problems and requirements inherent to the ALE formulation, mainly related to the mesh motion and deformation of the fluid domain. As a secondary outcome of this work, it is important to point out that the choice of the solver also influenced the reliability of the final results. PMID:27128798

  16. The role of invasive sonography in the differential diagnosis and treatment of intraabdominal fluid collections.

    PubMed

    Regöly-Mérei, J; Ihász, M; Szeberin, Z; Záborszky, A

    Sixty-nine ultrasound-guided interventions (23 punctures and 46 drainages) were performed on 51 patients with the suspicion of intraabdominal abscess or another type of fluid collection in a prospective-controlled study. Of the procedures, 58.8% were carried out following surgery, while in 41.2% the indication were not related to prior surgical intervention. Repeated procedures were done in 10 patients. In the group of punctures the procedure was therapeutic in 3 cases and diagnostic in 16 patients. The drainage was technically successful in 92.7%. The drain was displaced or blocked in 27% (n = 10), but reinterventions were necessary in only 5 cases for this reason. The total number of redrainages was 18.9%. The percutaneous (pc) drainage was insufficient in 8 patients (21.6%), all these patients were operated on. 62.2% of the patients recovered after pc drainage, 13.5% following redrainage (total 75.5%). In 8.1% of the cases after pc drainage and in 5.4% after pc redrainage open surgery became necessary. There was only one complication due to the procedure. Seven patients (14.3%) died of the disease which indicated the procedure. There were no fatal outcomes on the account of the intervention. Ultrasound-guided puncture is a suitable method to indicate or contraindicate open surgery in the case of intraabdominal fluid collection. The diagnostic puncture may be followed by sonographically guided drainage or in selected cases by therapeutic puncture, but if the pc drainage is insufficient, open surgery should be performed in time.

  17. The metal content of molybdenum-mineralizing fluids

    NASA Astrophysics Data System (ADS)

    Lerchbaumer, L.; Audétat, A.

    2012-04-01

    Molybdenum can be found in porphyry-type systems as well as in hydrothermal veins and breccias associated with granite systems. Up to now our knowledge on the metal content of fluids forming molybdenum ore deposits has been very limited. The only data available so far are from the porphyry Mo deposit at Questa, New Mexico, and from the Cave Peak porphyry Mo-Nb deposit in Texas. We have studied early, intermediate-density fluid inclusions in quartz crystals from miarolitic cavities in the Drammen and Glitrevann granites (Norway) and the Treasure Mountain Dome (Colorado/USA) to obtain more information about the bulk composition of magmatic-hydrothermal fluids exsolved from these plutons. The Treasure Mountain Dome contains weak Mo mineralization and is an apophysis of the Alma Batholith that produced also the famous Climax and Henderson porphyry Mo deposits; the Glitrevann granite hosts a sub-economic Mo stockwork, and the Drammen Granite contains numerous vein-type Mo mineralizations. As a preliminary result, based on analyses of fluid inclusions using optical microscopy, microthermometry, Raman spectroscopy, and LA-ICP-MS we conclude that the primordial fluid of the Drammen granite was of high acidity and carried certain amounts of metals at conditions of 650°C and 1.3-1.5 kbar. The total elemental budget is: 3 wt% Na, 1.8 wt% K, 0.5 wt% S, 0.4 wt% Fe, 0.3 wt% Cu, 0.2 wt% Mn, 40 ppm Mo, 800 ppm Zn, 600 ppm Rb, 300 ppm Cs, 180 ppm Pb, 150 ppm As, 40 ppm W, 15 ppm Bi, and minor amounts of Ag, Sn, and Ce. Striking is the fact, that all the metal concentrations show little variability except the one of Cu. In view of recent studies (Lerchbaumer & Audétat, 2011) showing that the Cu-values in quartz-hosted fluid inclusions are not always representative of the primary fluid and in fact can be too high, we want to check if this could be the case for the Cu-values measured in the samples from Norway and Colorado. The alteration of the original Cu-concentrations stems from post-entrapment diffusion of Cu+ through the host quartz into the fluid inclusions. The trigger for this process is the changing pH of the outer fluid due to rock-buffered cooling: As this fluid gets more and more basic, the increasing concentration gradient promotes the loss of H+ from existing fluid inclusions and the corresponding uptake of Cu+. In order to experimentally reconstruct this process we will put a well characterized trail of fluid inclusions from the Drammen granite into a gold capsule together with its original, acidic fluid (known from analyses mentioned above) and subject it to its forming conditions in rapid quench autoclaves. In the case of fluid inclusions with a diffusively altered elemental composition, the pH-difference between the fluid inclusions and the outer fluid would reverse the diffusion process and would lead to quite diminished concentrations of Cu after the run. Such a result would finally indicate that these Mo-mineralizing fluids hardly transported any Cu. Lerchbaumer L. & Audétat A. (2011): Preferential partitioning of copper into the vapor phase: An artifact? Mineralogical Magazine 75 (3), 1302.

  18. Turbine Fuels from Tar Sands Bitumen and Heavy Oil. Phase I. Preliminary Process Analysis.

    DTIC Science & Technology

    1985-04-09

    OIL RESERVOIRS OF THE UNITED STATES Resource: Oil -in-Place State Field Name (County) (Million Bbls.) Arkansas Smackover Old (Union) 1,6U0 California...Flow Schematic for Gas Oil Feed Hydrotreater 94 14 Summary of Case Studies for Processing Bitumen from New Mexico 95 15 Summary of Case Studies for...Naphtha Hydrotreating Process Estimates 112 14 Gas Oil Hydrocracking Process Estimates 113 l! Gas Oil Hydrotreating Process Estimate 114 16 Fluid

  19. Advanced Supercritical Carbon Dioxide Brayton Cycle Development

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Anderson, Mark; Sienicki, James; Moisseytsev, Anton

    2015-10-21

    Fluids operating in the supercritical state have promising characteristics for future high efficiency power cycles. In order to develop power cycles using supercritical fluids, it is necessary to understand the flow characteristics of fluids under both supercritical and two-phase conditions. In this study, a Computational Fluid Dynamic (CFD) methodology was developed for supercritical fluids flowing through complex geometries. A real fluid property module was implemented to provide properties for different supercritical fluids. However, in each simulation case, there is only one species of fluid. As a result, the fluid property module provides properties for either supercritical CO 2 (S-CO 2)more » or supercritical water (SCW). The Homogeneous Equilibrium Model (HEM) was employed to model the two-phase flow. HEM assumes two phases have same velocity, pressure, and temperature, making it only applicable for the dilute dispersed two-phase flow situation. Three example geometries, including orifices, labyrinth seals, and valves, were used to validate this methodology with experimental data. For the first geometry, S-CO 2 and SCW flowing through orifices were simulated and compared with experimental data. The maximum difference between the mass flow rate predictions and experimental measurements is less than 5%. This is a significant improvement as previous works can only guarantee 10% error. In this research, several efforts were made to help this improvement. First, an accurate real fluid module was used to provide properties. Second, the upstream condition was determined by pressure and density, which determines supercritical states more precise than using pressure and temperature. For the second geometry, the flow through labyrinth seals was studied. After a successful validation, parametric studies were performed to study geometric effects on the leakage rate. Based on these parametric studies, an optimum design strategy for the see-through labyrinth seals was proposed. A stepped labyrinth seal, which mimics the behavior of the labyrinth seal used in the Sandia National Laboratory (SNL) S-CO 2 Brayton cycle, was also tested in the experiment along with simulations performed. The rest of this study demonstrates the difference of valves' behavior under supercritical fluid and normal fluid conditions. A small-scale valve was tested in the experiment facility using S-CO 2. Different percentages of opening valves were tested, and the measured mass flow rate agreed with simulation predictions. Two transients from a real S-CO 2 Brayton cycle design provided the data for valve selection. The selected valve was studied using numerical simulation, as experimental data is not available.« less

  20. The effect of chronic prostatitis on zinc concentration of prostatic fluid and seminal plasma: a systematic review and meta-analysis.

    PubMed

    Cui, Dong; Han, GuangWei; Shang, YongGang; Mu, LiJun; Long, QingZhi; Du, YueFeng

    2015-01-01

    Prostatitis is a common disease in urology departments. Prostatic zinc accumulation is connected with the secretory function of the prostate, and zinc concentrations present in prostatic diseases differ greatly from the normal level. Studies have investigated the effect of chronic prostatitis on zinc concentration of prostatic fluid and seminal plasma, but have shown inconsistent results. Hence, we performed a systematic literature review and meta-analysis to assess the effect of chronic prostatitis on the zinc concentration of prostatic fluid and seminal plasma. Systematic literature searches were conducted with PubMed, Embase, Science Direct/Elsevier, CNKI and the Cochrane Library up to March 2015 for case-control studies that involved the relationship between chronic prostatitis and zinc concentration of prostatic fluid and seminal plasma. Meta-analysis was performed with Review Manager and Stata software. Standard mean differences (SMDs) of zinc concentration were identified with 95% confidence intervals (95% CIs) in a random- or fixed-effects model. Our results illustrated that the zinc concentrations in prostatic fluid and seminal plasma from chronic prostatitis patients were significantly lower than normal controls (SMD [95% CI] -246.71 [-347.97, -145.44], -20.74 [-35.11, -6.37], respectively). The sample size of each study was relatively small, and a total of 731 chronic prostatitis patients and 574 normal controls were investigated in all fourteen studies. Several studies related to the subject were excluded due to lack of control data or means and standard deviations. The present study illustrates that there was a significant negative effect of chronic prostatitis on zinc concentrations of prostatic fluid and seminal plasma. Further studies with larger sample sizes are needed to better illuminate the negative impact of chronic prostatitis on zinc concentrations.

  1. Association between cytochrome P450 2D6 polymorphisms and body fluid methamphetamine concentrations in Japanese forensic autopsy cases.

    PubMed

    Matsusue, Aya; Ikeda, Tomoya; Tani, Naoto; Waters, Brian; Hara, Kenji; Kashiwagi, Masayuki; Takayama, Mio; Ikematsu, Natsuki; Kubo, Shin-Ichi; Ishikawa, Takaki

    2018-05-18

    Methamphetamine (MA) is an illicit stimulant that affects the central nervous system. Cytochrome P450 2D6 (CYP2D6) plays an important role in MA metabolism. Numerous allelic variants confer substantial variation in CYP2D6 activity among individuals. In the present study, we examined the frequencies of CYP2D6 alleles, including CYP2D6*1, *2, *4, *5, *10, *14A, *14B, *18, and *36, and multiplication, in 82 forensic autopsy cases of MA abusers and 567 autopsy cases in which MA was not detected (controls). Ultrarapid metabolizer (UM), extensive metabolizer (EM), intermediate metabolizer (IM), and poor metabolizer (PM) phenotypes were predicted from CYP2D6 genotypes. Of MA abusers, 64 subjects were predicted to be EM, 17 were IM, and 1 was UM. No MA abuser had the predicted PM phenotype. No significant differences in CYP2D6 phenotype frequencies were found between MA abusers and controls. MA and amphetamine (AMP) concentrations were measured in the right heart blood, left heart blood, peripheral external iliac blood, urine, pericardial fluid, and bone marrow of MA abusers. MA concentrations in urine and bone marrow were significantly higher in IM than in EM. AMP concentration was not associated with CYP2D6 phenotype in any body fluid. These results suggest that the MA concentration in body fluids is influenced by CYP2D6 phenotypes in the Japanese population. Copyright © 2018 Elsevier B.V. All rights reserved.

  2. On the relationship between kinetic and fluid formalisms for convection in the inner magnetosphere

    NASA Astrophysics Data System (ADS)

    Song, Yang; Sazykin, Stanislav; Wolf, Richard A.

    2008-08-01

    In the inner magnetosphere, the plasma flows are mostly slow compared to thermal or Alfvén speeds, but the convection is far away from the ideal magnetohydrodynamic regime since the gradient/curvature drifts become significant. Both kinetic (Wolf, 1983) and two-fluid (Peymirat and Fontaine, 1994; Heinemann, 1999) formalisms have been used to describe plasma dynamics, but it is not fully understood how they relate to each other. We explore the relations among kinetic, fluid, and recently developed "average" (Liu, 2006) models in an attempt to find the simplest yet realistic way to describe the convection. First, we prove analytically that the model of (Liu, 2006), when closed with the assumption of a Maxwellian distribution, is equivalent to the fluid model of (Heinemann, 1999). Second, we analyze the transport of both one-dimensional and two-dimensional Gaussian-shaped blob of hot plasma. For the kinetic case, it is known that the time evolution of such a blob is gradual spreading in time. For the fluid case, Heinemann and Wolf (2001a, 2001b) showed that in a one-dimensional idealized case, the blob separates into two drifting at different speeds. We present a fully nonlinear solution of this case, confirming this behavior but demonstrating what appears to be a shocklike steepening of the faster drifting secondary blob. A new, more realistic two-dimensional example using the dipole geometry with a uniform electric field confirms the one-dimensional solutions. Implications for the numerical simulations of magnetospheric dynamics are discussed.

  3. Physical activity, inflammatory biomarkers in gingival crevicular fluid and periodontitis.

    PubMed

    Sanders, Anne E; Slade, Gary D; Fitzsimmons, Tracy R; Bartold, Peter Mark

    2009-05-01

    To examine the associations of physical activity with interleukin 1-beta (IL-1beta), C-reactive protein (CRP) and periodontitis and to investigate whether any relationship between physical activity and inflammatory mediators differs between periodontitis cases and non-cases. In this population-based case control study of Australians aged 18+ years, dentists conducted oral epidemiologic examinations identifying cases with moderate or severe periodontitis and periodontally healthy controls. Gingival crevicular fluid samples collected during examinations were analysed for inflammatory biomarkers. Subject-completed questionnaires assessed leisure-time physical activity. Exposure odds ratios (ORs) were estimated in multivariable logistic regression models adjusting for periodontitis risk indicators. Of 751 subjects (359 cases, 392 controls), those meeting a prescribed threshold for leisure-time physical activity had lower adjusted odds of elevated IL-1beta: OR=0.69, (95% CI=0.50-0.94) and detectable CRP: OR=0.70 (0.50-0.98) than less active adults. Physical activity was not associated with periodontitis: OR=1.14 (0.80-1.62). Periodontitis modified the association between levels of physical activity and detectable CRP. Increasing quartiles of physically activity were associated with decreasing probability of detectable CRP, but the effect was limited to periodontitis cases and was not apparent among non-cases. Leisure-time physical activity may protect against an excessive inflammatory response in periodontitis.

  4. Use of duraseal in repair of cerebrospinal fluid leaks.

    PubMed

    Chin, Christopher J; Kus, Lukas; Rotenberg, Brian W

    2010-10-01

    The purpose of our article is to review the use of the DuraSeal Sealant System (Confluent Surgical Inc., Waltham, MA) in the repair of complex cerebrospinal fluid (CSF) leaks in endoscopic skull-base surgery. Retrospective chart review. London Health Sciences Centre. A database of endoscopic skull-base cases between 2007 and 2009 that involved CSF leakage repaired with DuraSeal was created. Demographic data and operative reports were collected and analyzed qualitatively. Recurrence of CSF leak after repair. Five cases were identified that met study criteria. In four of the five cases, the repair was successful. There were no complications related to DuraSeal use. Comparison to a subset of patients using Tisseel Fibrin Sealant (Baxter, Toronto, ON) for repair did not show a significant difference in failure rate (χ2 = 0.029, p = .858). There are a variety of techniques described to repair CSF rhinorrhea, with various studies demonstrating the advantages of using tissue glues in CSF leak repairs. We used DuraSeal in five patients to enhance graft strength and form a watertight seal. The system was effective in the majority of patients. Our study is the first to report on endoscopic endonasal repair of CSF leaks using DuraSeal.

  5. On the physics-based processes behind production-induced seismicity in natural gas fields

    NASA Astrophysics Data System (ADS)

    Zbinden, Dominik; Rinaldi, Antonio Pio; Urpi, Luca; Wiemer, Stefan

    2017-04-01

    Induced seismicity due to natural gas production is observed at different sites around the world. Common understanding is that the pressure drop caused by gas production leads to compaction, which affects the stress field in the reservoir and the surrounding rock formations, hence reactivating pre-existing faults and inducing earthquakes. Previous studies have often assumed that pressure changes in the reservoir compartments and intersecting fault zones are equal, while neglecting multi-phase fluid flow. In this study, we show that disregarding fluid flow involved in natural gas extraction activities is often inappropriate. We use a fully coupled multiphase fluid flow and geomechanics simulator, which accounts for stress-dependent permeability and linear poroelasticity, to better determine the conditions leading to fault reactivation. In our model setup, gas is produced from a porous reservoir, cut in two compartments that are offset by a normal fault, and overlain by impermeable caprock. Results show that fluid flow plays a major role pertaining to pore pressure and stress evolution within the fault. Hydro-mechanical processes include rotation of the principal stresses due to reservoir compaction, as well as poroelastic effects caused by the pressure drop in the adjacent reservoir. Fault strength is significantly reduced due to fluid flow into the fault zone from the neighbouring reservoir compartment and other formations. We also analyze the case of production in both compartments, and results show that simultaneous production does not prevent the fault to be reactivated, but the magnitude of the induced event is smaller. Finally, we analyze scenarios for minimizing seismicity after a period of production, such as (i) well shut-in and (ii) gas re-injection. Results show that, in the case of well shut-in, a highly stressed fault zone can still be reactivated several decades after production stop, although in average the shut-in results in reduction of seismicity. In the case of gas re-injection, fault reactivation can be avoided if gas is injected directly into the compartment under depletion. However, accounting for continuous production at a given reservoir and gas re-injection at a neighbouring compartment does not stop the fault from being reactivated.

  6. Case study: fatal poisoning by malathion.

    PubMed

    Thompson, T S; Treble, R G; Magliocco, A; Roettger, J R; Eichhorst, J C

    1998-07-20

    A case involving a fatal poisoning (suicide) by the insecticide malathion is described. The intact insecticide was found in the post-mortem blood and gastric contents at concentrations of 1.8 and 978 micrograms/ml, respectively. None of the insecticide was found in the autopsied liver tissue. Gas chromatography-mass spectrometry (GC-MS) techniques were used for the identification and quantification of malathion in the body fluids.

  7. Exact solutions for oscillatory shear sweep behaviors of complex fluids from the Oldroyd 8-constant framework

    NASA Astrophysics Data System (ADS)

    Saengow, Chaimongkol; Giacomin, A. Jeffrey

    2018-03-01

    In this paper, we provide a new exact framework for analyzing the most commonly measured behaviors in large-amplitude oscillatory shear flow (LAOS), a popular flow for studying the nonlinear physics of complex fluids. Specifically, the strain rate sweep (also called the strain sweep) is used routinely to identify the onset of nonlinearity. By the strain rate sweep, we mean a sequence of LAOS experiments conducted at the same frequency, performed one after another, with increasing shear rate amplitude. In this paper, we give exact expressions for the nonlinear complex viscosity and the corresponding nonlinear complex normal stress coefficients, for the Oldroyd 8-constant framework for oscillatory shear sweeps. We choose the Oldroyd 8-constant framework for its rich diversity of popular special cases (we list 18 of these). We evaluate the Fourier integrals of our previous exact solution to get exact expressions for the real and imaginary parts of the complex viscosity, and for the complex normal stress coefficients, as functions of both test frequency and shear rate amplitude. We explore the role of infinite shear rate viscosity on strain rate sweep responses for the special case of the corotational Jeffreys fluid. We find that raising η∞ raises the real part of the complex viscosity and lowers the imaginary. In our worked examples, we thus first use the corotational Jeffreys fluid, and then, for greater accuracy, we use the Johnson-Segalman fluid, to describe the strain rate sweep response of molten atactic polystyrene. For our comparisons with data, we use the Spriggs relations to generalize the Oldroyd 8-constant framework to multimode. Our generalization yields unequivocally, a longest fluid relaxation time, used to assign Weissenberg and Deborah numbers to each oscillatory shear flow experiment. We then locate each experiment in the Pipkin space.

  8. A mean curvature model for capillary flows in asymmetric containers and conduits

    NASA Astrophysics Data System (ADS)

    Chen, Yongkang; Tavan, Noël; Weislogel, Mark M.

    2012-08-01

    Capillarity-driven flows resulting from critical geometric wetting criterion are observed to yield significant shifts of the bulk fluid from one side of the container to the other during "zero gravity" experiments. For wetting fluids, such bulk shift flows consist of advancing and receding menisci sometimes separated by secondary capillary flows such as rivulet-like flows along gaps. Here we study the mean curvature of an advancing meniscus in hopes of approximating a critical boundary condition for fluid dynamics solutions. It is found that the bulk shift flows behave as if the bulk menisci are either "connected" or "disconnected." For the connected case, an analytic method is developed to calculate the mean curvature of the advancing meniscus in an asymptotic sense. In contrast, for the disconnected case the method to calculate the mean curvature of the advancing and receding menisci uses a well-established procedure. Both disconnected and connected bulk shifts can occur as the first tier flow of more complex compound capillary flows. Preliminary comparisons between the analytic method and the results of drop tower experiments are encouraging.

  9. Thermal stratification potential in rocket engine coolant channels

    NASA Technical Reports Server (NTRS)

    Kacynski, Kenneth J.

    1992-01-01

    The potential for rocket engine coolant channel flow stratification was computationally studied. A conjugate, 3-D, conduction/advection analysis code (SINDA/FLUINT) was used. Core fluid temperatures were predicted to vary by over 360 K across the coolant channel, at the throat section, indicating that the conventional assumption of a fully mixed fluid may be extremely inaccurate. Because of the thermal stratification of the fluid, the walls exposed to the rocket engine exhaust gases will be hotter than an assumption of full mixing would imply. In this analysis, wall temperatures were 160 K hotter in the turbulent mixing case than in the full mixing case. The discrepancy between the full mixing and turbulent mixing analyses increased with increasing heat transfer. Both analysis methods predicted identical channel resistances at the coolant inlet, but in the stratified analysis the thermal resistance was negligible. The implications are significant. Neglect of thermal stratification could lead to underpredictions in nozzle wall temperatures. Even worse, testing at subscale conditions may be inadequate for modeling conditions that would exist in a full scale engine.

  10. Numerical simulation of compressor endwall and casing treatment flow phenomena

    NASA Technical Reports Server (NTRS)

    Crook, A. J.; Greitzer, E. M.; Tan, C. S.; Adamczyk, J. J.

    1992-01-01

    A numerical study is presented of the flow in the endwall region of a compressor blade row, in conditions of operation with both smooth and grooved endwalls. The computations are first compared to velocity field measurements in a cantilevered stator/rotating hub configuration to confirm that the salient features are captured. Computations are then interrogated to examine the tip leakage flow structure since this is a dominant feature of the endwall region. In particular, the high blockage that can exist near the endwalls at the rear of a compressor blade passage appears to be directly linked to low total pressure fluid associated with the leakage flow. The fluid dynamic action of the grooved endwall, representative of the casing treatments that have been most successful in suppressing stall, is then simulated computationally and two principal effects are identified. One is suction of the low total pressure, high blockage fluid at the rear of the passage. The second is energizing of the tip leakage flow, most notably in the core of the leakage vortex, thereby suppressing the blockage at its source.

  11. [Intrauterine fetal therapy of NIHF with massive pleural effusion - a case study].

    PubMed

    Sobczuk, Kamila; Wojtera, Justyna; Celewicz, Zbigniew; Szaflik, Krzysztof

    2013-05-01

    Hydrops fetalis (fetal hydrops) is a serious fetal condition defined as abnormal accumulation of fluid in two or more extravascular compartments, including ascites, pleural effusion, pericardial effusion, and skin edema. Edema is classified as immune or non-immune. Today more than 90% of fetal edema has non-immune cause. This paper presents a case of a pregnant woman who was admitted to the Obstetrics and Gynecology Department because of fetal hydrops with massive pleural effusion and polyhydramnios at 34 weeks gestation. The intrauterine therapy consisted of two treatments. During the first surgery amnioreduction, evacuation of fluid from the pleural cavity of the fetus, and shunts to both pleural cavities were performed. During the second surgery amnioreduction, cordocentesis with albumin administration and pleural shunt were performed. Intrauterine therapy led to a reduction of swelling of the fetus from 7mm up to 1-2 mm and the total evacuation of fluid from the pleural cavity and the fetal lung expansion. We also present the condition of the neonate after birth and after 12 months of life.

  12. Spectroscopic Measurement of Ion Flow During Merging Start-up of Field-Reversed Configuration

    NASA Astrophysics Data System (ADS)

    Oka, Hirotaka; Inomoto, Michiaki; Tanabe, Hiroshi; Annoura, Masanobu; Ono, Yasushi; Nemoto, Koshichi

    2012-10-01

    The counter-helicity merging method [1] of field-reversed configuration (FRC) formation involves generation of bidirectional toroidal flow, known as a ``sling-shot.'' In two fluids regime, reconnection process is strongly affected by the Hall effect [2]. In this study, we have investigated the behavior of toroidal bidirectional flow generated by the counter-helicity merging in two-fluids regime. We use 2D Ion Doppler Spectroscopy to mesure toroidal ion flow during merging start-up of FRC from Ar gas. We defined two cases: one case with a radially pushed-in X line (case I) and the other case with a radially pushed-out X line(case O). The flow during the plasma merging shows radial asymmetry, as expected from the magnetic measurement, but finally relaxes to a unidirectional flow in plasma current direction in both cases. We observed larger toroidal flow in the plasma current direction in case I after FRC is formed, though the FRC in case O has larger magnetic flux. These results suggest that more ions are lost during merging start-up in case I. This selective ion loss might account for stability and confinement of FRCs probably maintained by high energy ions.[4pt] [1] Y. Ono, et al., Nucl. Fusion 39, pp. 2001-2008 (1999).[0pt] [2] M. Inomoto, et al., Phys. Rev. Lett., 97, 135002, (2006)

  13. Etude d'un modele de Boltzmann sur reseau pour la simulation assistee par ordinateur des fluides a plusieurs phases immiscibles

    NASA Astrophysics Data System (ADS)

    Leclaire, Sebastien

    The computer assisted simulation of the dynamics of fluid flow has been a highly rewarding topic of research for several decades now, in terms of the number of scientific problems that have been solved as a result, both in the academic world and in industry. In the fluid dynamics field, simulating multiphase immiscible fluid flow remains a challenge, because of the complexity of the interactions at the flow phase interfaces. Various numerical methods are available to study these phenomena, and, the lattice Boltzmann method has been shown in recent years to be well adapted to solving this type of complex flow. In this thesis, a lattice Boltzmann model for the simulation of two-phase immiscible flows is studied. The main objective of the thesis is to develop this promising method further, with a view to enhancing its validity. To achieve this objective, the research is divided into five distinct themes. The first two focus on correcting some of the deficiencies of the original model. The third generalizes the model to support the simulation of N-phase immiscible fluid flows. The fourth is aimed at modifying the model itself, to enable the simulation of immiscible fluid flows in which the density of the phases varies. With the lattice Boltzmann class of models studied here, this density variation has been inadequately modeled, and, after 20 years, the issue still has not been resolved. The fifth, which complements this thesis, is connected with the lattice Boltzmann method, in that it generalizes the theory of 2D and 3D isotropic gradients for a high order of spatial precision. These themes have each been the subject of a scientific article, as listed in the appendix to this thesis, and together they constitute a synthesis that explains the links between the articles, as well as their scientific contributions, and satisfy the main objective of this research. Globally, a number of qualitative and quantitative test cases based on the theory of multiphase fluid flows have highlighted issues plaguing the simulation model. These test cases have resulted in various modifications to the model, which have reduced or eliminated some numerical artifacts that were problematic. They also allowed us to validate the extensions that were applied to the original model.

  14. Flow of viscoplastic suspensions in a hydraulic fracture: implications to overflush

    NASA Astrophysics Data System (ADS)

    Boronin, S. A.; Osiptsov, A. A.; Desroches, J.

    2017-10-01

    The study is devoted to modeling of multiphase flows of immiscible viscoplastic fluids in a hydraulic fracture. In the framework of the lubrication approximation, three-dimensional Navier-Stokes equations are reduced to hyperbolic transport equations for the fluid tracers and a quasi-linear elliptic equation in terms of the fluid pressure. The governing equations are solved numerically using the finite-difference approach. A parametric study of the displacement of Bingham fluids in a Hele-Shaw cell is carried out. It is found that fingers developed through the pillar of a yield-stress suspension trigger the development of unyielded zones. An increase in the Bingham number leads to an increase in the so-called finger shielding effect, which manifests itself via an increase in the overall finger penetration zone and a decrease in the total number of fingers. The effect of flow parameters on the displacement of hydraulic fracturing proppant-laden suspension by a clean fluid in the vicinity of the perforation zone is carried out. This particular case is considered in application to overflush at the end of a stimulation treatment, when a small portion of a thin clean fluid is injected to wash out the particles from the wellbore into the fracture. It is found that an increase in the yield stress and the viscosity contrast between the fracturing and the overflush fluids typically reduces the area of the cavity thus mitigating the risk of loosing the conductive path between the wellbore and the fracture after the fracture closure.

  15. Real-Time Observations of Food and Fluid Timing During a 120 km Ultramarathon.

    PubMed

    Wardenaar, Floris C; Hoogervorst, Daan; Versteegen, Joline J; van der Burg, Nancy; Lambrechtse, Karin J; Bongers, Coen C W G

    2018-01-01

    The aim of the present case study was to use real-time observations to investigate ultramarathon runners' timing of food and fluid intake per 15 km and per hour, and total bodyweight loss due to dehydration. The study included 5 male ultramarathon runners observed during a 120 km race. The research team members followed on a bicycle and continuously observed their dietary intake using action cameras. Hourly carbohydrate intake ranged between 22.1 and 62.6 g/h, and fluid intake varied between 260 and 603 mL/h. These numbers remained relatively stable over the course of the ultra-endurance marathon. Runners consumed food and fluid on average 3-6 times per 15 km. Runners achieved a higher total carbohydrate consumption in the second half of the race ( p = 0.043), but no higher fluid intake ( p = 0.08). Energy gels contributed the most to the total average carbohydrate intake (40.2 ± 25.7%). Post-race weight was 3.6 ± 2.3% (range 0.3-5.7%) lower than pre-race weight, revealing a non-significant ( p = 0.08) but practical relevant difference. In conclusion, runners were able to maintain a constant timing of food and fluid intake during competition but adjusted their food choices in the second half of the race. The large variation in fluid and carbohydrate intake indicate that recommendations need to be individualized to further optimize personal intakes.

  16. Pressure-controlled drainage of cerebrospinal fluid: clinical experience with a new type of ventricular catheter (Ventcontrol MTC)and an integrated Piezo-resistive sensor at its tip: technical note.

    PubMed

    Piek, J; Raes, P

    1996-01-01

    We described a new ventricular catheter that is the combination of a "classic" ventricular catheter with a piezo-resistive transducer at its tip. The device allows parallel recordings of intraventricular fluid pressure via a chip and a fluid-filled external transducer, drainage of cerebrospinal fluid from the ventricle or injection of fluid into the ventricle with simultaneous monitoring of intracranial pressure, and recording of brain tissue pressure in cases of misplacement or dislocation of the ventricular catheter or in cases of progressively narrowing ventricles caused by brain edema. Clinical tests in various situations at different pressure ranges (total recording time, 1356 h in 13 patients) gave excellent correlations of both pressures. Application of the device is especially indicated in clinical situations in which pressure-controlled drainage is desirable, occlusion of ventricular bolts is likely, or pressure-volume tests are needed.

  17. Growth rate of a penny-shaped crack in hydraulic fracturing of rocks

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Abe, H.; Keer, L.M.; Mura, T.

    1976-01-01

    The deformation and growth of a crack, fractured hydraulically, is investigated when fluid is injected from an inlet into the crack at a constant flow rate. The total flow rate at the inlet is divided as follows: flow rate extracted from an outlet hole; fluid loss rate from the crack surface; and total fluid mass change in the crack. Two cases are considered: (1) inlet flow rate is initially greater than the sum of the outlet flow and fluid loss rates; and (2) the reverse holds true. Ranges are shown for which the crack attains stationary states for given inletmore » flow rate and outlet pressure. For these two cases reasonable outlet flow rates are obtained when the outlet pressure is less than or equal to the difference between the tectonic stress and the fluid head at the inlet. Results are expected to be of use in considerations of heat extraction from hot, dry rock.« less

  18. Asymptotic behavior of the mixed mass in Rayleigh–Taylor and Richtmyer–Meshkov instability induced flows

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhou, Ye; Cabot, William H.; Thornber, Ben

    Rayleigh–Taylor instability (RTI) and Richtmyer–Meshkov instability (RMI) are serious practical issues in inertial confinement fusion research, and also have relevance to many cases of astrophysical fluid dynamics. So far, much of the attention has been paid to the late-time scaling of the mixed width, which is used as a surrogate to how well the fluids have been mixed. Yet, the actual amount of mixed mass could be viewed as a more direct indicator on the evolution of the mixing layers due to hydrodynamic instabilities. Despite its importance, there is no systematic study as yet on the scaling of the mixedmore » mass for either the RTI or the RMI induced flow. In this article, the normalized mixed mass (Ψ) is introduced for measuring the efficiency of the mixed mass. Six large numerical simulation databases have been employed: the RTI cases with heavy-to-light fluid density ratios of 1.5, 3, and 9; the single shock RMI cases with density ratios of 3 and 20; and a reshock RMI case with density ratio of 3. Using simulated flow fields, the normalized mixed mass Ψ is shown to be more sensitive in discriminating the variation with Atwood number for the RTI flows. Moreover, Ψ is demonstrated to provide more consistent results for both the RTI and RMI flows when compared with the traditional mixedness parameters, Ξ and Θ.« less

  19. FLUID PURIFIER AND SEALING VALVE

    DOEpatents

    Swanton, W.F.

    1962-04-24

    An improved cold trap designed to condense vapors and collect foreign particles in a flowing fluid is described. In the arrangement, a valve is provided to prevent flow reversal in case of pump failure and to act as a sealing valve. Provision is made for reducing the temperature of the fluid being processed, including a pre-cooling stage. (AEC)

  20. Thermodynamic transport properties of nitrogen tetroxide in hypercritical conditions for regenerative cooling of a rocket engine. Volume 1: Tests

    NASA Astrophysics Data System (ADS)

    Saccoccia, Giorgio

    The thermodynamical and transport properties are studied for nitrogen tetroxide (N2O4), which is utilized in hypercritical conditions as oxidants and cooling fluids in rocket propulsion with regenerative cooling systems. An equation of state was performed in the varied zone of the state diagram, taking into account the phase change and two dissociation reactions. The study of the transport properties and state effects is based on the results of the fluid molecular theory. In addition to the state effects, the simple application results obtained for a case of thermal exchange in a cooling channel was studied through the behavior of the substance.

  1. Social profit in the context of the activities at Fluids Measurement Sector in Legal Metrology Department - Inmetro

    NASA Astrophysics Data System (ADS)

    Cinelli, L. R.; Silva, L. G.; Junior, E. A.; Almeida, R. O.

    2018-03-01

    This article was prepared in the context of the work of the Fluids Measurement Sector (Seflu) of the Legal Metrology Department of Inmetro (Dimel) in order to try to answer the following question: What is the magnitude of Social Profit generated for brazilian society from the existence of legal control of measuring instruments within the scope of this sector? In this sense, some examples of a case study containing the main measurement instruments related to the evaluation process of models performed at the Seflu are presented.

  2. Particle-fluid interaction corrections for flow measurements with a laser Doppler flowmeter

    NASA Technical Reports Server (NTRS)

    Berman, N. S.

    1972-01-01

    A discussion is given of particle lags in mean flows, acoustic oscillations at single frequencies and in turbulent flows. Some simplified cases lead to exact solutions. For turbulent flows linearization of the equation of motion after assuming the fluid and particle streamlines coincide also leads to a solution. The results show that particle lags are a function of particle size and frequency of oscillation. Additional studies are necessary to evaluate the effect of turbulence when a major portion of the energy is concentrated in small eddies.

  3. Metagenomic Sequencing of an Echovirus 30 Genome From Cerebrospinal Fluid of a Patient With Aseptic Meningitis and Orchitis.

    PubMed

    Piantadosi, Anne; Mukerji, Shibani S; Chitneni, Pooja; Cho, Tracey A; Cosimi, Lisa A; Hung, Deborah T; Goldberg, Marcia B; Sabeti, Pardis C; Kuritzkes, Daniel R; Grad, Yonatan H

    2017-01-01

    Enteroviruses cause a wide spectrum of clinical disease. In this study, we describe the case of a young man with orchitis and aseptic meningitis who was diagnosed with enterovirus infection. Using unbiased "metagenomic" massively parallel sequencing, we assembled a near-complete viral genome, the first use of this method for full-genome viral sequencing from cerebrospinal fluid. We found that the genome belonged to the subgroup echovirus 30, which is a common cause of aseptic meningitis but has not been previously reported to cause orchitis.

  4. Incidental Intraosseous Pneumatocyst with gas-density-fluid level in an adolescent: a case report and review of the literature

    PubMed Central

    Al-Tarawneh, Emad; AL-Qudah, Mohammad; Hadidi, Fadi; Jubouri, Shams; Hadidy, Azmy

    2014-01-01

    Intraosseous pneumatocyst is a gas containing lesion located within a bone. It is a relatively rare condition of unclear etiology and with an undetermined natural course. Gas-density-fluid level pneumatocyst is even rarer. Pneumatocyst is frequently seen in adults but rarely reported in pediatrics. The lesion is usually small and is seen in the vertebral bodies as well as around the sacroiliac joints. Rarely does it occur in other parts of the skeleton. We are reporting a case of large blood signal intensity containing intraosseous pneumatocyst in a 14 year old boy and reviewing other pediatric cases of pneumatocysts as well as those with gas-density-fluid level. The recognition of this incidental rare benign lesion is essential to avoid over investigation and an inappropriate aggressive intervention. PMID:24967024

  5. Spectrophotometry of cerebrospinal fluid in subacute and chronic subdural haematomas

    PubMed Central

    Kjellin, K. G.; Steiner, L.

    1974-01-01

    Spectrophotometric examinations were performed on cerebrospinal and subdural fluids in subacute (five patients) and chronic (20 patients) subdural haematomas, with special reference to the diagnostic aid of CSF spectrophotometry. Spectrophotometric xanthochromia of haemorrhagic origin was found in all CSFs examined, while definite visible xanthochromia was observed in only 28% and the CSF was judged as colourless in 52% of those cases. Characteristic bleeding patterns were found spectrophotometrically in all the 20 CSFs examined within 24 hours after lumbar puncture, haematoma patterns being detected in 90-95% of the cases. In many cases the electrophoretically separated protein fractions of CSF and subdural fluids were spectrophotometrically examined. In conclusion, CSF spectrophotometry is a simple, fast, and extremely sensitive method, which in our opinion should be used routinely in the diagnosis of suspected subdural haematomas, if lumbar puncture is not contraindicated. PMID:4140892

  6. Improvement of the limit torque for the torque limiter with magnetic rheological fluid

    NASA Astrophysics Data System (ADS)

    Umehara, Noritsugu; Kita, Shizuo

    Robots are coming to support and help our life. The robots that work together with human need to avoid sever hitting and holding that force is more than the adequate and comfortable range. In order to keep the force to the safe level in the robot arms, t he limit torque should be controlled on the basis of the case the robot used. Magnetic rheological fluids were tried to be used for the clutch that transmission torque can be controlled continuously because MR fluids can be controlled its viscosity by magnetic field. However those clutch devices were too heavy and large to use for the robot arms. Therefore we tried to increase the sensitivity of magnetic field to viscosity of MR fluids. By applying rough surface for the mating surface, sensitivity of the magnetic field to the shearing torque increase drastically in the case of co-axial torque meter. On the other hand, the changing of the size of the orifice is effective to increase the sensitivity of the magnetic field on the flow resistance in the case of the orifice type equipment.

  7. Convertible socket for pressure gauge

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bissell, R.D.

    1990-01-01

    This patent describes a pressure gauge having a case in which is disposed a Bourdon tube and a base socket connected to the Bourdon tube for placing the tube in pressure communication with a fluid pressure source. Base socket has a rearward face and a bottom face with respect to the gauge adjacent openings defined through the case and an internal passage communication with the tube. It includes means for connecting a source of fluid pressure to the socket selectively through one of the case openings to the bottom face or the rearward face.

  8. Homogenization of one-dimensional draining through heterogeneous porous media including higher-order approximations

    NASA Astrophysics Data System (ADS)

    Anderson, Daniel M.; McLaughlin, Richard M.; Miller, Cass T.

    2018-02-01

    We examine a mathematical model of one-dimensional draining of a fluid through a periodically-layered porous medium. A porous medium, initially saturated with a fluid of a high density is assumed to drain out the bottom of the porous medium with a second lighter fluid replacing the draining fluid. We assume that the draining layer is sufficiently dense that the dynamics of the lighter fluid can be neglected with respect to the dynamics of the heavier draining fluid and that the height of the draining fluid, represented as a free boundary in the model, evolves in time. In this context, we neglect interfacial tension effects at the boundary between the two fluids. We show that this problem admits an exact solution. Our primary objective is to develop a homogenization theory in which we find not only leading-order, or effective, trends but also capture higher-order corrections to these effective draining rates. The approximate solution obtained by this homogenization theory is compared to the exact solution for two cases: (1) the permeability of the porous medium varies smoothly but rapidly and (2) the permeability varies as a piecewise constant function representing discrete layers of alternating high/low permeability. In both cases we are able to show that the corrections in the homogenization theory accurately predict the position of the free boundary moving through the porous medium.

  9. Temporal and spatial variation in porosity and compaction pressure for the viscoelastic slab

    NASA Astrophysics Data System (ADS)

    Morishige, M.; Van Keken, P. E.

    2017-12-01

    Fluid is considered to play key roles in subduction zones. It triggers various types of earthquakes by elevating pore-fluid pressure or forming hydrous minerals, and it also facilitates magma genesis by lowering the solidus temperatures of mantle and crustal rocks. Several previous numerical studies have worked on how fluid migrates and how porosity changes in time and space, but our knowledge of the fluid behavior remains limited. In this presentation, we demonstrate the detailed fluid behavior in the slab. The main features of this study are that (1) viscoelasticity is included, and that (2) fluid flow toward the inner part of the slab is also considered. We construct 2D and 3D finite element models for viscoelastic slab based on a theory of two-phase flow, which allows us to treat the movement of rock- and fluid- phases simultaneously. We solve the equations for porosity and compaction pressure which is defined as the pressure difference in between the two phases. Fluid source is fixed in time and space, and a uniform slab velocity is imposed for the whole model domain. There are several important parameters affecting the fluid behavior which includes bulk viscosity, bulk modulus, permeability, and fluid viscosity. Among these we fix bulk modulus and change the other parameters to investigate their effects on fluid migration. We find that when bulk viscosity is relatively high, elasticity is dominant and large amount of fluid is trapped in and around the fluid source. In addition, fluid migrates along the fluid source when relatively high ratio of permeability to fluid viscosity is assumed. Fluid generally moves with the slab when the ratio of permeability to fluid viscosity is low. One interesting feature is that in some cases porosity increases also in the deeper part of the fluid source due to the diffusion of compaction pressure. It suggests that the effects of resistance to volume change can be an alternative mechanism to effectively hydrate the inner part in the slab. In 3D, we find that fluid migrates in the maximum-dip direction of the slab. It leads to a fluid focusing where the slab bends away from the trench and it results in the increase in porosity and compaction pressure there. This finding may be useful to explain the observed along-arc variation in short-term slow slip events and the upper plane of double seismic zone.

  10. Retrospective study of 14 cases of canine arthritis secondary to Leishmania infection.

    PubMed

    Sbrana, S; Marchetti, V; Mancianti, F; Guidi, G; Bennett, D

    2014-06-01

    To describe the clinical appearance, laboratory findings and response to treatment of dogs with inflammatory joint disease associated with Leishmania infection. Retrospective analysis of case records of dogs with serologically confirmed leishmaniasis and concurrent inflammatory joint disease presented between 2005 and 2011. In total, 14 cases met the inclusion criteria. Of these, five (36%) dogs were presented with monoarthritis, five (36%) with oligoarthritis and four (28%) with polyarthritis. The most frequently affected joint was the carpus. Both erosive and non-erosive disease was identified on radiographic examination. All dogs had an inflammatory synovial fluid with a high white cell count and a preponderance of neutrophils, and in eight (57%) cases Leishmania amastigotes were found in the synovial fluid smears. Dogs were treated with 50 mg/kg N-methylglucamine antimoniate twice a day for 1 month and 10 mg/kg allopurinol twice a day for 6 to 9 months combined with prednisolone in five cases. At the 6-month follow-up, eight (57%) dogs showed improvement in general and orthopaedic signs and four (28%) dogs were stable. Leishmaniasis should be considered a differential diagnosis in dogs with inflammatory arthritis in endemic areas. © 2014 British Small Animal Veterinary Association.

  11. Hyponatremia in distance runners: fluid and sodium balance during exercise.

    PubMed

    Noakes, Tim

    2002-08-01

    Since its first description in 1985, two opposing theories have evolved to explain the etiology of symptomatic hyponatremia of exercise. The first holds that the condition occurs only in athletes who lose both water and sodium during exercise, and fail to fully replace their sodium losses. The second theory holds that the symptomatic form of this condition occurs in athletes who generate a whole body fluid overload as a result of an excessive fluid intake during prolonged exercise. It is argued that the promotion of the idea that athletes should drink as much as possible during exercise has produced, rather than prevented, the recent increase in the incidence of this condition. A series of case reports and laboratory studies reported in the past 2 years have established that it is a whole body fluid overload, resulting from sustained high rates of fluid intake, that causes the symptomatic hyponatremia of exercise. There is no evidence that, in the absence of fluid overload, the usual sodium deficits generated during exercise can cause this condition. These findings confirm that the potentially fatal condition of symptomatic hyponatremia would be eliminated from sport immediately if all athletes were advised of the dangers of ingesting as much fluid as possible during any exercise that lasts more than 4 hours.

  12. Do Arthroscopic Fluid Pumps Display True Surgical Site Pressure During Hip Arthroscopy?

    PubMed

    Ross, Jeremy A; Marland, Jennifer D; Payne, Brayden; Whiting, Daniel R; West, Hugh S

    2018-01-01

    To report on the accuracy of 5 commercially available arthroscopic fluid pumps to measure fluid pressure at the surgical site during hip arthroscopy. Patients undergoing hip arthroscopy for femoroacetabular impingement were block randomized to the use of 1 of 5 arthroscopic fluid pumps. A spinal needle inserted into the operative field was used to measure surgical site pressure. Displayed pump pressures and surgical site pressures were recorded at 30-second intervals for the duration of the case. Mean differences between displayed pump pressures and surgical site pressures were obtained for each pump group. Of the 5 pumps studied, 3 (Crossflow, 24K, and Continuous Wave III) reflected the operative field fluid pressure within 11 mm Hg of the pressure readout. In contrast, 2 of the 5 pumps (Double Pump RF and FMS/DUO+) showed a difference of greater than 59 mm Hg between the operative field fluid pressure and the pressure readout. Joint-calibrated pumps more closely reflect true surgical site pressure than gravity-equivalent pumps. With a basic understanding of pump design, either type of pump can be used safely and efficiently. The risk of unfamiliarity with these differences is, on one end, the possibility of pump underperformance and, on the other, potentially dangerously high operating pressures. Level II, prospective block-randomized study. Copyright © 2017. Published by Elsevier Inc.

  13. Estimation of gestational age from study of amniotic fluid and clinical assessment.

    PubMed Central

    Deshpande, T. V.; Harding, P. G.; Jaco, N. T.

    1977-01-01

    Study of 108 samples of amniotic fluid obtained between 28 and 42 weeks' gestation from 101 patients revealed that in normal pregnancies the creatinine concentration, lecithin/sphingomyelin (L/S) ratio and percentage of fat cells correlated better with the gestational age of the newborn--assessed by clinical criteria--than did the bilirubin and sodium concentrations. A creatinine concentration of 1.75 mg/dL or more, an L/S ratio of 4 or more and a fat cell percentage of 10 or more correlated significantly with a gestational age of 37 weeks or more. In abnormal pregnancies (those with obstetric or medical complications, or both) the mean creatinine concentration in the amniotic fluid was significantly less than expected for gestational age in fetal dysmaturity and greater than expected when the mother had diabetes. The mean L/S ratio in the amniotic fluid was elevated when the mother had hypertension or smoked and in cases of fetal dysmaturity or long interval between rupture of the membranes and delivery, whereas it was significantly lower than normal when the mother had diabetes. The mean bilirubin concentration in the amniotic fluid was significantly lower than normal when the mother had hypertension. When the mother had diabetes, maturity of the fetal lung, liver, skin and brain appeared to be delayed, according to the values for the amniotic fluid constituents. PMID:912615

  14. Blood volume-monitored regulation of ultrafiltration in fluid-overloaded hemodialysis patients: study protocol for a randomized controlled trial.

    PubMed

    Hecking, Manfred; Antlanger, Marlies; Winnicki, Wolfgang; Reiter, Thomas; Werzowa, Johannes; Haidinger, Michael; Weichhart, Thomas; Polaschegg, Hans-Dietrich; Josten, Peter; Exner, Isabella; Lorenz-Turnheim, Katharina; Eigner, Manfred; Paul, Gernot; Klauser-Braun, Renate; Hörl, Walter H; Sunder-Plassmann, Gere; Säemann, Marcus D

    2012-06-08

    Data generated with the body composition monitor (BCM, Fresenius) show, based on bioimpedance technology, that chronic fluid overload in hemodialysis patients is associated with poor survival. However, removing excess fluid by lowering dry weight can be accompanied by intradialytic and postdialytic complications. Here, we aim at testing the hypothesis that, in comparison to conventional hemodialysis, blood volume-monitored regulation of ultrafiltration and dialysate conductivity (UCR) and/or regulation of ultrafiltration and temperature (UTR) will decrease complications when ultrafiltration volumes are systematically increased in fluid-overloaded hemodialysis patients. BCM measurements yield results on fluid overload (in liters), relative to extracellular water (ECW). In this prospective, multicenter, triple-arm, parallel-group, crossover, randomized, controlled clinical trial, we use BCM measurements, routinely introduced in our three maintenance hemodialysis centers shortly prior to the start of the study, to recruit sixty hemodialysis patients with fluid overload (defined as ≥15% ECW). Patients are randomized 1:1:1 into UCR, UTR and conventional hemodialysis groups. BCM-determined, 'final' dry weight is set to normohydration weight -7% of ECW postdialysis, and reached by reducing the previous dry weight, in steps of 0.1 kg per 10 kg body weight, during 12 hemodialysis sessions (one study phase). In case of intradialytic complications, dry weight reduction is decreased, according to a prespecified algorithm. A comparison of intra- and post-dialytic complications among study groups constitutes the primary endpoint. In addition, we will assess relative weight reduction, changes in residual renal function, quality of life measures, and predialysis levels of various laboratory parameters including C-reactive protein, troponin T, and N-terminal pro-B-type natriuretic peptide, before and after the first study phase (secondary outcome parameters). Patients are not requested to revert to their initial degree of fluid overload after each study phase. Therefore, the crossover design of the present study merely serves the purpose of secondary endpoint evaluation, for example to determine patient choice of treatment modality. Previous studies on blood volume monitoring have yielded inconsistent results. Since we include only patients with BCM-determined fluid overload, we expect a benefit for all study participants, due to strict fluid management, which decreases the mortality risk of hemodialysis patients. ClinicalTrials.gov, NCT01416753.

  15. Blood volume-monitored regulation of ultrafiltration in fluid-overloaded hemodialysis patients: study protocol for a randomized controlled trial

    PubMed Central

    2012-01-01

    Background Data generated with the body composition monitor (BCM, Fresenius) show, based on bioimpedance technology, that chronic fluid overload in hemodialysis patients is associated with poor survival. However, removing excess fluid by lowering dry weight can be accompanied by intradialytic and postdialytic complications. Here, we aim at testing the hypothesis that, in comparison to conventional hemodialysis, blood volume-monitored regulation of ultrafiltration and dialysate conductivity (UCR) and/or regulation of ultrafiltration and temperature (UTR) will decrease complications when ultrafiltration volumes are systematically increased in fluid-overloaded hemodialysis patients. Methods/design BCM measurements yield results on fluid overload (in liters), relative to extracellular water (ECW). In this prospective, multicenter, triple-arm, parallel-group, crossover, randomized, controlled clinical trial, we use BCM measurements, routinely introduced in our three maintenance hemodialysis centers shortly prior to the start of the study, to recruit sixty hemodialysis patients with fluid overload (defined as ≥15% ECW). Patients are randomized 1:1:1 into UCR, UTR and conventional hemodialysis groups. BCM-determined, ‘final’ dry weight is set to normohydration weight −7% of ECW postdialysis, and reached by reducing the previous dry weight, in steps of 0.1 kg per 10 kg body weight, during 12 hemodialysis sessions (one study phase). In case of intradialytic complications, dry weight reduction is decreased, according to a prespecified algorithm. A comparison of intra- and post-dialytic complications among study groups constitutes the primary endpoint. In addition, we will assess relative weight reduction, changes in residual renal function, quality of life measures, and predialysis levels of various laboratory parameters including C-reactive protein, troponin T, and N-terminal pro-B-type natriuretic peptide, before and after the first study phase (secondary outcome parameters). Discussion Patients are not requested to revert to their initial degree of fluid overload after each study phase. Therefore, the crossover design of the present study merely serves the purpose of secondary endpoint evaluation, for example to determine patient choice of treatment modality. Previous studies on blood volume monitoring have yielded inconsistent results. Since we include only patients with BCM-determined fluid overload, we expect a benefit for all study participants, due to strict fluid management, which decreases the mortality risk of hemodialysis patients. Trial registration ClinicalTrials.gov, NCT01416753 PMID:22682149

  16. [Endonasal endoscopic surgery in the treatment of spontaneous or post-traumatic cerebrospinal fluid (csf) leaks].

    PubMed

    Nallet, E; Decq, P; Bezzo, A; Le Lievre, G; Peynegre, R; Coste, A

    1998-10-01

    The incidence and the risk of meningitidis justify treatment in all cases of cerebrospinal fluid rhinorrhea with spontaneous etiology or after traumatic injury. Endonasal surgery with endoscopic instruments provides many advantages compared with transcranial or transfacial approach used by neurosurgeons. We report our experience and our surgical technique in the treatment of CSF leaks in 5 patients. Intrathecal injection of fluoresceine was very useful in all cases for detecting the CSF leak. Total or selected ethmoidectomy depended on the localization of the leakage. Wide sphenoidotomy enables detection and repair of CSF leaks from the sphenoid cavity. A free graft of inferior turbinal mucosal was used to repair the breache. This rapid low morbidity surgery offered secure closure of rhinorrhea in 4 cases after one procedure and in 1 case after two procedures with an average follow up of 22 months. Cerebrospinal fluid rhinorrhea can be managed in first line therapy with endoscopic intranasal surgical techniques when they are localized in the anterior ethmoid or in the sphenoid cavity.

  17. Diverter bop system and method for a bottom supported offshore drilling rig

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Roche, J. R.; Alexander, G. G.; Carbaugh, W. L.

    1985-06-25

    A system and method for installing a fluid flow controller and telescoping spools beneath an offshore bottom supported drilling rig rotary table is disclosed. Upper and lower telescoping spools are provided for initially connecting a Diverter/BOP convertible fluid flow controller between structural casing in the well and a permanent housing beneath the drilling rig rotary table. Clamp means are provided for clamping the rig vent line to an opening in the housing wall of the fluid flow controller during drilling of the borehole through the structural casing in preparation for setting and cementing the conductor casing. In that mode, themore » system is adapted as a diverter system. After the well is drilled for the conductor casing and the conductor casing is cemented and cut off at its top, a mandrel is fitted at the top of the conductor casing to which the lower end of the lower spool may be connected. The system may be used in this configuration as a diverter system, or after removal of the vent line and connection of a kill line to the housing outlet, the system may be used as a low pressure blowout preventer system.« less

  18. Ascites Index - a novel technique to evaluate ascites in ovarian hyperstimulation syndrome: a concept-proof study.

    PubMed

    Szkodziak, Piotr Robert; Czuczwar, Piotr; Wrona, Wojciech; Paszkowski, Tomasz; Szkodziak, Filip; Woźniak, Sławomir

    2018-01-01

    Controlled ovarian hyperstimulation is an important step in infertility treatment. In some cases, however, ovar-ian hyperstimulation syndrome (OHSS) can occur. In its severe forms, ascites is likely to develop, associated with dyspnea. The aim of this study was to explore the usefulness of Ascites Index (AsI), a new tool for quantitative determination of ascites in patients with OHSS, to obtain data for planning further trials. Twelve patients with OHSS and ascites were included in the study. All patients were admitted to the hospital because of abdominal pain and dyspnea due to increasing ascites. Ultrasound measurements of ascites extent were performed in four external quadrants of the abdomen. Pockets of free fluid were measured. The obtained values were totaled, forming the Ascites Index (AsI), similarly to the amniotic fluid index. Because of dyspnea, paracentesis was performed in all cases. Median AsI at which patients reported dyspnea was 29.0 cm (range 21.6-38.6 cm). At AsI values less than 21.6 cm, no dyspnea was observed in any of the 12 studied patients. To avoid complications, 2000 mL of ascitic fluid was collected in each patient. After paracentesis, range of AsI decreased to 12.1-14.5 cm. The proposed AsI seems to be a promising tool for estimating and monitoring the ascites extent in OHSS. It can be estimated using basic ultrasound equipment. AsI requires further studies for standardization and transferability to other causes of ascites.

  19. New influence factor inducing difficulty in selective flotation separation of Cu-Zn mixed sulfide minerals

    NASA Astrophysics Data System (ADS)

    Deng, Jiu-shuai; Mao, Ying-bo; Wen, Shu-ming; Liu, Jian; Xian, Yong-jun; Feng, Qi-cheng

    2015-02-01

    Selective flotation separation of Cu-Zn mixed sulfides has been proven to be difficult. Thus far, researchers have found no satisfactory way to separate Cu-Zn mixed sulfides by selective flotation, mainly because of the complex surface and interface interaction mechanisms in the flotation solution. Undesired activation occurs between copper ions and the sphalerite surfaces. In addition to recycled water and mineral dissolution, ancient fluids in the minerals are observed to be a new source of metal ions. In this study, significant amounts of ancient fluids were found to exist in Cu-Zn sulfide and gangue minerals, mostly as gas-liquid fluid inclusions. The concentration of copper ions released from the ancient fluids reached 1.02 × 10-6 mol/L, whereas, in the cases of sphalerite and quartz, this concentration was 0.62 × 10-6 mol/L and 0.44 × 10-6 mol/L, respectively. As a result, the ancient fluid is a significant source of copper ions compared to mineral dissolution under the same experimental conditions, which promotes the unwanted activation of sphalerite. Therefore, the ancient fluid is considered to be a new factor that affects the selective flotation separation of Cu-Zn mixed sulfide ores.

  20. CTP (Cochlin-tomoprotein) detection in the profuse fluid leakage (gusher) from cochleostomy.

    PubMed

    Ikezono, Tetsuo; Sugizaki, Kazuki; Shindo, Susumu; Sekiguchi, Satomi; Pawankar, Ruby; Baba, Shunkichi; Yagi, Toshiaki

    2010-08-01

    By testing 125 samples, we confirmed that Cochlin-tomoprotein (CTP) is present in the perilymph, not in cerebrospinal fluid (CSF). Perilymph and CSF exist in two distinct compartments, even in the case of a malformed inner ear with a bony defect in the lamina cribrosa, as described here. Cochleostomy might have suddenly decreased the perilymph pressure, allowing the influx of CSF into the inner ear resulting in profuse fluid leakage, first perilymph then CSF. The first purpose of this study was to further confirm the specificity of the perilymph-specific protein CTP that we reported recently. Secondly, we assessed the nature of the fluid leakage from the cochleostomy using the CTP detection test. A standardized CTP detection test was performed on 65 perilymph and 60 CSF samples. Samples of profuse fluid leakage collected from cochleostomy during cochlear implantation surgery of one patient with branchio-oto-renal (BOR) syndrome were also tested by the CTP detection test. CTP was detected in 60 of 65 perilymph samples but not in any of the CSF samples. The leaked fluid was shown to contain CTP, i.e. perilymph, at the outset, and then the CTP detection signals gradually disappeared as time elapsed.

  1. Effect of humidity on posterior lens opacification during fluid-air exchange.

    PubMed

    Harlan, J B; Lee, E T; Jensen, P S; de Juan, E

    1999-06-01

    To study the relationship of humidity and the rate of lens opacity formation during fluid-air exchange using an animal model. Vitrectomy and fluid-air exchange was carried out using 16 eyes of 8 pigmented rabbits. One eye of each rabbit was exposed to dry air and the fellow eye received humidified air using an intraocular air humidifier. In each case, the percent humidity of the intraocular air was measured using an in-line hygrometer. Elapsed time from initial air entry to lens feathering was recorded for each eye, with the surgeon-observer unaware of the percent humidity of the air infusion. In each rabbit, use of humidified air resulted in a delay in lens feathering (P<.02), with an overall increase in time to feathering of 80% for humidified air vs room air. Use of a humidifier during fluid-air exchange prolongs intraoperative lens clarity in the rabbit model, suggesting that humidified air should prolong lens clarity during phakic fluid-air exchange in patients. Use of humidified air during vitrectomy and fluid-air exchange may retard the intraoperative loss of lens clarity, promoting better visualization of the posterior segment and enhancing surgical performance.

  2. The value of mutational profiling of the cytocentrifugation supernatant fluid from fine-needle aspiration of pancreatic solid mass lesions.

    PubMed

    Deftereos, Georgios; Finkelstein, Sydney D; Jackson, Sara A; Ellsworth, Eric M G; Krishnamurti, Uma; Liu, Yulin; Silverman, Jan F; Binkert, Candy R; Ujevich, Beth A; Mohanty, Alok

    2014-04-01

    Fine-needle aspiration (FNA) of pancreatic solid masses can be significantly impacted by sampling variation. Molecular analysis of tumor DNA can be an aid for more definitive diagnosis. The aim of this study was to evaluate how molecular analysis of the cell-free cytocentrifugation supernatant DNA can help reduce sampling variability and increase diagnostic yield. Twenty-three FNA smears from pancreatic solid masses were performed. Remaining aspirates were rinsed for preparation of cytocentrifuged slides or cell blocks. DNA was extracted from supernatant fluid and assessed for DNA quantity spectrophotometrically and for amplifiability by quantitative PCR (qPCR). Supernatants with adequate DNA were analyzed for mutations using PCR/capillary electrophoresis for a broad panel of markers (KRAS point mutation by sequencing, microsatellite fragment analysis for loss of heterozygosity (LOH) of 16 markers at 1p, 3p, 5q, 9p, 10q, 17p, 17q, 21q, and 22q). In selected cases, microdissection of stained cytology smears and/or cytocentrifugation cellular slides were analyzed and compared. In all, 5/23 samples cytologically confirmed as adenocarcinoma showed detectable mutations both in the microdissected slide-based cytology cells and in the cytocentrifugation supernatant. While most mutations detected were present in both microdissected slides and supernatant fluid specimens, the latter showed additional mutations supporting greater sensitivity for detecting relevant DNA damage. Clonality for individual marker mutations was higher in the supernatant fluid than in microdissected cells. Cytocentrifugation supernatant fluid contains levels of amplifiable DNA suitable for mutation detection and characterization. The finding of additional detectable mutations at higher clonality indicates that supernatant fluid may be enriched with tumor DNA. Molecular analysis of the supernatant fluid could serve as an adjunct method to reduce sampling variability and increase diagnostic yield, especially in cases with a high clinical suspicion for malignancy and limited number of atypical cells in the smears.

  3. Moderately nonlinear ultrasound propagation in blood-mimicking fluid.

    PubMed

    Kharin, Nikolay A; Vince, D Geoffrey

    2004-04-01

    In medical diagnostic ultrasound (US), higher than-in-water nonlinearity of body fluids and tissue usually does not produce strong nonlinearly distorted waves because of the high absorption. The relative influence of absorption and nonlinearity can be characterized by the Gol'dberg number Gamma. There are two limiting cases in nonlinear acoustics: weak waves (Gamma < 1) or strong waves (Gamma > 1). However, at diagnostic frequencies in tissue and body fluids, the nonlinear effects and effects of absorption more likely are comparable (Gol'dberg number Gamma approximately 1). The aim of this work was to study the nonlinear propagation of a moderately nonlinear US second harmonic signal in a blood-mimicking fluid. Quasilinear solutions to the KZK equation are presented, assuming radiation from a flat and geometrically focused circular Gaussian source. The solutions are expressed in a new simplified closed form and are in very good agreement with those of previous studies measuring and modeling Gaussian beams. The solutions also show good agreement with the measurements of the beams produced by commercially available transducers, even without special Gaussian shading.

  4. Periodontitis-associated septic pulmonary embolism caused by Actinomyces species identified by anaerobic culture of bronchoalveolar lavage fluid: a case report.

    PubMed

    Endo, Shun; Mishima, Eikan; Takeuchi, Yoichi; Ohi, Takashi; Ishida, Masatsugu; Yanai, Masaru; Kiyomoto, Hideyasu; Nagasawa, Tasuku; Ito, Sadayoshi

    2015-12-01

    Periodontal disease is a less common but important cause of septic pulmonary embolism (SPE). However, the pathogens causing periodontal disease-associated SPE (PD-SPE) have been poorly understood. Actinomyces species are resident microbiota in the oral cavity. Here we report a case of PD-SPE caused by Actinomyces species, which was identified by anaerobic culture of bronchoalveolar lavage fluid (BAL). A 64-year-old Asian man, complicated with severe chronic periodontitis, was admitted with chest pain and fever. Chest CT revealed multiple bilateral pulmonary nodules located subpleurally. We diagnosed the case as SPE associated with periodontitis. Although blood cultures were negative for the usual 5-day incubation, anaerobic culture of the BAL fluid sample yielded Actinomyces species. Antibacterial therapy alone did not ameliorate the symptoms; however, additional dental treatment, including tooth extraction, promptly did. The patient was discharged 23 days after admission. The 3-month follow-up revealed no recurrence of the symptoms and complete resolution of the lung lesions. This case demonstrated that Actinomyces species can cause PD-SPE. Additionally, clinicians should consider performing appropriate anaerobic culture of BAL fluid to identify the pathogen of SPE, and to ordering dental treatment, if necessary, in addition to antibiotics for the initial management of PD-SPE.

  5. Testing density-dependent groundwater models: Two-dimensional steady state unstable convection in infinite, finite and inclined porous layers

    USGS Publications Warehouse

    Weatherill, D.; Simmons, C.T.; Voss, C.I.; Robinson, N.I.

    2004-01-01

    This study proposes the use of several problems of unstable steady state convection with variable fluid density in a porous layer of infinite horizontal extent as two-dimensional (2-D) test cases for density-dependent groundwater flow and solute transport simulators. Unlike existing density-dependent model benchmarks, these problems have well-defined stability criteria that are determined analytically. These analytical stability indicators can be compared with numerical model results to test the ability of a code to accurately simulate buoyancy driven flow and diffusion. The basic analytical solution is for a horizontally infinite fluid-filled porous layer in which fluid density decreases with depth. The proposed test problems include unstable convection in an infinite horizontal box, in a finite horizontal box, and in an infinite inclined box. A dimensionless Rayleigh number incorporating properties of the fluid and the porous media determines the stability of the layer in each case. Testing the ability of numerical codes to match both the critical Rayleigh number at which convection occurs and the wavelength of convection cells is an addition to the benchmark problems currently in use. The proposed test problems are modelled in 2-D using the SUTRA [SUTRA-A model for saturated-unsaturated variable-density ground-water flow with solute or energy transport. US Geological Survey Water-Resources Investigations Report, 02-4231, 2002. 250 p] density-dependent groundwater flow and solute transport code. For the case of an infinite horizontal box, SUTRA results show a distinct change from stable to unstable behaviour around the theoretical critical Rayleigh number of 4??2 and the simulated wavelength of unstable convection agrees with that predicted by the analytical solution. The effects of finite layer aspect ratio and inclination on stability indicators are also tested and numerical results are in excellent agreement with theoretical stability criteria and with numerical results previously reported in traditional fluid mechanics literature. ?? 2004 Elsevier Ltd. All rights reserved.

  6. Lumbosacral Radiculoplexopathy as the Initial Presentation of Lymphoma: A Report of 4 Cases.

    PubMed

    Marquardt, Robert J; Li, Yuebing

    2018-06-01

    To evaluate the clinical, laboratory, and radiological features of 4 cases of biopsy-proven lymphomatous lumbosacral radiculoplexopathy. Retrospective chart review. All patients suffered from diffuse large B-cell lymphoma. A mean diagnostic delay of 10 months was encountered. Presenting symptoms in all 4 patients included back pain, radicular leg pain, and leg weakness, similar to spondylotic radiculopathy. Electrodiagnostic study showed axon loss radiculoplexopathy and magnetic resonance imaging of the lumbar spine or pelvis demonstrated nerve or nerve root enhancement. Increased uptake by lumbosacral roots/plexus on fluorodeoxyglucose-positron emission tomography aided diagnosis in 3 cases. Cytology was positive in 1 of 10 cerebrospinal fluid samples. Combined chemotherapy and radiation treatment led to clinicoradiological improvement, with residual neurological symptoms in all patients. Lymphomatous lumbosacral radiculoplexopathy should be considered in patients with progressive lumbosacral radicular symptoms. Magnetic resonance imaging and fluorodeoxyglucose-positron emission tomography, but not cerebrospinal fluid, are helpful in achieving early diagnosis. Treatment responses seem favorable.

  7. [Studies on flomoxef in the perinatal period].

    PubMed

    Cho, N; Fukunaga, K; Kunii, K; Kobayashi, I

    1991-06-01

    Pharmacokinetic, bacteriological and clinical studies on flomoxef (FMOX) in the perinatal period were carried out with the following summary of the results. Antibacterial effects of FMOX on the growth of methicillin-resistant Staphylococcus aureus (MRSA, MIC 400 micrograms/ml), methicillin-sensitive S. aureus (MSSA, MIC 0.78 microgram/ml), Escherichia coli (MIC 3.13 micrograms/ml and MIC 0.20 microgram/ml) in amniotic fluid were determined and it was found that the activity of FMOX was enhanced in the amniotic fluid. FMOX rapidly penetrated into tissues and sera of pregnant women upon intravenous injection and its maternal serum concentrations reached their peak levels shortly after administration. Placental penetration of FMOX to the fetus was good and, after single intravenous injection of 1 g, the concentrations of FMOX in the umbilical cord serum and amniotic fluid exceeded MICs against major causative organisms of perinatal infections. These results indicate that single intravenous injection of FMOX 1 g twice a day is effective for the treatment and prophylaxis of perinatal infections. Injection of FMOX for the treatment of 14 cases of puerperal infections showed excellent clinical effectiveness with 100% clinical effect and 81.8% bacteriological response. No side-effect was observed in any case. All of these results suggested clinical usefulness of FMOX in the perinatal period.

  8. Milk of calcium stones: radiological signs and management outcome.

    PubMed

    El-Shazly, M

    2015-06-01

    Milk of calcium (MOC) is a rare type of stone that was first described in 1940 by Ludin and Howald who reported MOC in renal cysts. Milk of calcium is a viscous colloidal suspension of calcium salts. Stasis, obstruction and infection are important predisposing factors. Due to a layering effect, characteristic radiological signs especially in CT can help in diagnosis to avoid unsuccessful shock wave lithotripsy. This is the largest reported case series, in which radiological signs by CT scan to predict renal MOC stones, clinical picture and management outcome are described in detail. Cases with suspected renal milk of calcium stones were studied over 7 years (2008-2015). All cases were diagnosed preoperatively by non-contrast CT. Urine cultures were performed in all patients preoperatively. Intra-operative and postoperative findings were reported. Stones retrieved were sent for chemical analysis using an infrared method. Seven cases of milk of calcium renal stones were included in this study. These stones were faint radio-opaque in two cases and radiolucent in five cases. All cases were diagnosed preoperatively with non-contrast CT. Their Hounsfield units (HU) ranged from 114 to 612. All stones were located in a dependent position (gravitational effect) in the posterior aspect of dilated calyces. Five cases exhibited the typical fluid level and two cases demonstrated semilunar (half moon) pattern in the anterior surface of the stones. All cases underwent PCNL with suction and retrieval of soft stones without the need for disintegration. When stones demonstrate a low Hounsfield unit, are arranged in dependent positions within dilated calyces and exhibit fluid level or semilunar pattern on non-contrast CT, milk of calcium stones should be considered. PCNL is an effective modality for management of renal milk of calcium stones.

  9. Nonlinear unsteady convection on micro and nanofluids with Cattaneo-Christov heat flux

    NASA Astrophysics Data System (ADS)

    Mamatha Upadhya, S.; Raju, C. S. K.; Mahesha; Saleem, S.

    2018-06-01

    This is a theoretical study of unsteady nonlinear convection on magnetohydrodynamic fluid in a suspension of dust and graphene nanoparticles. For boosting the heat transport phenomena we consider the Cattaneo-Christov heat flux and thermal radiation. Dispersal of graphene nanoparticles in dusty fluids finds applications in biocompatibility, bio-imaging, biosensors, detection and cancer treatment, in monitoring stem cells differentiation etc. Initially the simulation is performed by amalgamation of dust (micron size) and nanoparticles into base fluid. Primarily existing partial differential system (PDEs) is changed to ordinary differential system (ODEs) with the support of usual similarity transformations. Consequently, the highly nonlinear ODEs are solved numerically through Runge-Kutta and Shooting method. The computational results for Non-dimensional temperature and velocity profiles are offered through graphs (ϕ = 0 and ϕ = 0.05) cases. Additionally, the numerical values of friction factor and heat transfer rate are tabulated numerically for various physical parameters obtained. We also validated the current outcomes with previously available study and found to be extremely acceptable. From this study we conclude that in the presence of nanofluid heat transfer rate and temperature distribution is higher compared to micro fluid.

  10. Cerebrospinal fluid PCR analysis and biochemistry in bodies with severe decomposition.

    PubMed

    Palmiere, Cristian; Vanhaebost, Jessica; Ventura, Francesco; Bonsignore, Alessandro; Bonetti, Luca Reggiani

    2015-02-01

    The aim of this study was to assess whether Neisseria meningitidis, Listeria monocytogenes, Streptococcus pneumoniae and Haemophilus influenzae can be identified using the polymerase chain reaction technique in the cerebrospinal fluid of severely decomposed bodies with known, noninfectious causes of death or whether postmortem changes can lead to false positive results and thus erroneous diagnostic information. Biochemical investigations, postmortem bacteriology and real-time polymerase chain reaction analysis in cerebrospinal fluid were performed in a series of medico-legal autopsies that included noninfectious causes of death with decomposition, bacterial meningitis without decomposition, bacterial meningitis with decomposition, low respiratory tract infections with decomposition and abdominal infections with decomposition. In noninfectious causes of death with decomposition, postmortem investigations failed to reveal results consistent with generalized inflammation or bacterial infections at the time of death. Real-time polymerase chain reaction analysis in cerebrospinal fluid did not identify the studied bacteria in any of these cases. The results of this study highlight the usefulness of molecular approaches in bacteriology as well as the use of alternative biological samples in postmortem biochemistry in order to obtain suitable information even in corpses with severe decompositional changes. Copyright © 2014 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.

  11. Scaling in two-fluid pinch-off

    NASA Astrophysics Data System (ADS)

    Pommer, Chris; Harris, Michael; Basaran, Osman

    2010-11-01

    The physics of two-fluid pinch-off, which arises whenever drops, bubbles, or jets of one fluid are ejected from a nozzle into another fluid, is scientifically important and technologically relevant. While the breakup of a drop in a passive environment is well understood, the physics of pinch-off when both the inner and outer fluids are dynamically active remains inadequately understood. Here, the breakup of a compound jet whose core and shell are incompressible Newtonian fluids is analyzed computationally when the interior is a "bubble" and the exterior is a liquid. The numerical method employed is an implicit method of lines ALE algorithm which uses finite elements with elliptic mesh generation and adaptive finite differences for time integration. Thus, the new approach neither starts with a priori idealizations, as has been the case with previous computations, nor is limited to length scales above that set by the wavelength of visible light as in any experimental study. In particular, three distinct responses are identified as the ratio m of the outer fluid's viscosity to the inner fluid's viscosity is varied. For small m, simulations show that the minimum neck radius r initially scales with time τ before breakup as r ˜0.58° (in accord with previous experiments and inviscid fluid models) but that r ˜τ once r becomes sufficiently small. For intermediate and large values of m, r ˜&αcirc;, where the exponent α may not equal one, once again as r becomes sufficiently small.

  12. Electro-osmosis of non-Newtonian fluids in porous media using lattice Poisson-Boltzmann method.

    PubMed

    Chen, Simeng; He, Xinting; Bertola, Volfango; Wang, Moran

    2014-12-15

    Electro-osmosis in porous media has many important applications in various areas such as oil and gas exploitation and biomedical detection. Very often, fluids relevant to these applications are non-Newtonian because of the shear-rate dependent viscosity. The purpose of this study was to investigate the behaviors and physical mechanism of electro-osmosis of non-Newtonian fluids in porous media. Model porous microstructures (granular, fibrous, and network) were created by a random generation-growth method. The nonlinear governing equations of electro-kinetic transport for a power-law fluid were solved by the lattice Poisson-Boltzmann method (LPBM). The model results indicate that: (i) the electro-osmosis of non-Newtonian fluids exhibits distinct nonlinear behaviors compared to that of Newtonian fluids; (ii) when the bulk ion concentration or zeta potential is high enough, shear-thinning fluids exhibit higher electro-osmotic permeability, while shear-thickening fluids lead to the higher electro-osmotic permeability for very low bulk ion concentration or zeta potential; (iii) the effect of the porous medium structure depends significantly on the constitutive parameters: for fluids with large constitutive coefficients strongly dependent on the power-law index, the network structure shows the highest electro-osmotic permeability while the granular structure exhibits the lowest permeability on the entire range of power law indices considered; when the dependence of the constitutive coefficient on the power law index is weaker, different behaviors can be observed especially in case of strong shear thinning. Copyright © 2014 Elsevier Inc. All rights reserved.

  13. Study of the Stability of Compressible Couette Flow.

    NASA Astrophysics Data System (ADS)

    Girard, Jeffrey John

    This study is concerned with a two-dimensional disturbance of plane Couette flow. All reviewed analyses of the basic problem have led to the conclusion that the flow is unconditionally stable. All of the literature assumed the fluid was incompressible. The assumption that a fluid is incompressible neglects solutions to the problem. The motivation of the analysis presented herein is a hypothesis that some of the acoustic disturbances in the fluid, usually neglected, may interact with the mean vorticity to produce more sound. This hypothesis was discussed by Vaidya (1988). The fluid considered herein has been a viscous, heat-conducting, ideal gas. For the cases investigated in this study, most solutions exhibited stability. There were found, however, solutions at somewhat unrealistically high Mach numbers which exhibited unstable nature. Further, it was found that for even low Mach number flows, the sound solution was the least stable solution. It is thought that the interaction between the sound perturbation and the mean flow has fed energy to the disturbance from the mean flow. Enough energy was transferred to balance some of the viscous dissipation. At low Mach numbers, for the investigated cases, not enough energy was transferred to tip the flow to instability. The established theory has been challenged. All previous analysis of the basic infinitesimal perturbation problem has suggested unconditional stability. This work has shown some unstable regimes. This keeps the hope alive that analysis may one day explain the experimental evidence (which is at much lower Mach numbers). The future work should concentrate on the sound solution for this problem. It has been shown to be the least stable, though it is usually neglected. An attempt should be made to investigate the possibility of reducing the lowest Mach number for instability. Suggestions for this have been provided in Chapter 4.

  14. Diagnosis of Persistent Infection in Prosthetic Two-Stage Exchange: Evaluation of the Effect of Sonication on Antibiotic Release from Bone Cement Spacers.

    PubMed

    Mariaux, Sandrine; Furustrand Tafin, Ulrika; Borens, Olivier

    2018-01-01

    Introduction : When treating periprosthetic joint infection with a two-stage procedure, antibiotic-impregnated spacers can be used in the interval between prosthetic removal and reimplantation. In our experience, cultures of sonicated spacers are most often negative. The objective of the study was to assess whether that sonication causes an elution of antibiotics, leading to elevated antibiotic concentrations in the sonication fluid inhibiting bacterial growth and thus causing false-negative cultures. Methods : A prospective monocentric study was performed from September 2014 to March 2016. Inclusion criteria were a two-stage procedure for prosthetic infection and agreement of the patient to participate in the study. Spacers were made of gentamicin-containing cement to which tobramycin and vancomycin were added. Antibiotic concentrations in the sonication fluid were determined by mass-spectometry (LC-MS). Results : 30 patients were identified (15 hip and 14 knee and 1 ankle arthroplasties). No cases of culture positive sonicated spacer fluid were observed in our serie. In the sonication fluid median concentrations of 13.2µg/ml, 392 µg/ml and 16.6 µg/ml were detected for vancomycin, tobramycin and gentamicin, respectively. According to the European Committee on antimicrobial susceptibility testing (EUCAST), these concentrations released from cement spacer during sonication are higher than the minimal inhibitory concentrations (MICs) for most bacteria relevant in prosthetic joint infections. Conclusion: Spacer sonication cultures remained sterile in all of our cases. Elevated concentrations of antibiotics released during sonication could explain partly negative-cultured sonicated spacers. Indeed, the absence of antibiotic free interval during the two-stages can also contribute to false-negative spacers sonicated cultures.

  15. Optic neuromyelitis syndrome in Brazilian patients

    PubMed Central

    Papais-Alvarenga, R; Miranda-Santos, C; Puccioni-Sohler, M; de Almeida, A M V; Oliveira, S; De Oliveira, C A B.; Alvarenga, H; Poser, C

    2002-01-01

    Objectives: To report the clinical features and outcome of 24 Brazilian patients with optic neuromyelitis syndrome (ONM); discuss the underlying pathological events associated with the ONM syndrome; review the nosological situation of ONM in the group of inflammatory and demyelinating diseases of the central nervous system. Patients and Methods: Patients with ONM treated at the Hospital da Lagoa, Rio de Janeiro were studied. Demographic, clinical, magnetic resonance imaging, cerebrospinal fluid, and pathological data were analysed. Results: The study consisted of 20 women, four men of whom 10 were white and 14 Afro-Brazilians. Clinical course was recurrent in 22 cases and monophasic in two. Neurological manifestations at inclusion were: sensory impairment (66%), bilateral (41.6%) or unilateral blindness (20.8%), paraplegia or quadriplegia (37.5%). The EDSS was moderate/severe in 70.8%. The underlying pathological events were respectively pulmonary tuberculosis and upper respiratory infection in the two monophasic cases; in the 22 recurrent ONM patients: pulmonary tuberculosis (3), neurocysticercosis (1), polyarteritis nodosa (1), antinuclear antibody and rheumatoid factor (1), antiphospholipid antibody primary syndrome (1), diabetes mellitus (1), hypothyroidism (1), and amenorrhea-galactorrhea (4). Normal cerebrospinal fluid was found in 52% and an inflammatory profile in 48%. Only four recurrent ONM white patients had brain and spinal cord magnetic resonance imaging and cerebrospinal fluid findings compatible with the diagnosis of multiple sclerosis. Large lesions were seen in 62% of spinal magnetic resonance images. Six of 12 recurrent ONM Afro-Brazilian died. There were no statistical differences in the demographic data of the two ethnic groups. Afro-Brazilians were significantly more severely impaired and had a higher mortality rate than the white patients. Conclusion: These cases were classified as follows: two monophasic acute disseminated encephalomyelitis; one recurrent disseminated encephalomyelitis; three recurrent ONM associated with Hughes syndrome, autoantibodies and polyarteritis nodosa; six recurrent ONM with endocrinopathies; and finally, four muliple sclerosis cases. The remaining cases were not associated with any other condition. It would seem clear that ONM is a syndrome rather than a single disease. PMID:12235313

  16. [Pharmacokinetic and clinical studies of flomoxef in the perinatal period].

    PubMed

    Matsuda, S; Hirayama, H; Oh, K; Tamate, K; Sengoku, K; Ishikawa, M; Shimizu, T; Haga, H; Hasegawa, T; Takada, H

    1993-07-01

    Pharmacokinetic and clinical studies on flomoxef (FMOX) in the perinatal period were carried out and following results were obtained 1. The pharmacokinetic parameter T1/2's of FMOX in maternal serum, umbilical cord serum and amniotic fluid in mothers after single intravenous injection of 1 g (n = 46) and 2 g (n = 34) were 1.11, 9.24, 9.24 hours and 2.54, 12.49, 12.49 hours, respectively. Cmax's and Tmax's of umbilical cord serum and amniotic fluid were 12.71, 11.77 micrograms/ml and 0.57, 3.35 hours upon single dose of 1 g i.v., and 35.17, 12.37 micrograms/ml and 0.32, 3.42 hours upon single dose of 2 g i.v., respectively. 2. Clinical usefulness were evaluated in 93 cases including were various infections in pregnancy and puerperal period. In pregnancy cases, clinical efficacy rate was 95.5% (21/22), and 100% in puerperal period. Bacteriological response rate was 84.6% (eradicated: 29, decreased: 4, unchanged: 2, replaced: 4 and unknown: 8 cases). No severe side effects nor clinical laboratory test results were observed in any cases. From above basic and clinical results, we conclude that FMOX is a useful and safe agent for various infections in pregnancy and puerperal period.

  17. Study of conformally flat polytropes with tilted congruence

    NASA Astrophysics Data System (ADS)

    Sharif, M.; Sadiq, Sobia

    This paper is aimed to study the modeling of spherically symmetric spacetime in the presence of anisotropic dissipative fluid configuration. This is accomplished for an observer moving relative to matter content using two cases of polytropic equation-of-state under conformally flat condition. We formulate the corresponding generalized Tolman-Oppenheimer-Volkoff equation, mass equation, as well as energy conditions for both cases. The conformally flat condition is imposed to find an expression for anisotropy which helps to study spherically symmetric polytropes. Finally, Tolman mass is used to analyze stability of the resulting models.

  18. Application of wave mechanics theory to fluid dynamics problems: Boundary layer on a circular cylinder including turbulence

    NASA Technical Reports Server (NTRS)

    Krzywoblocki, M. Z. V.

    1974-01-01

    The application of the elements of quantum (wave) mechanics to some special problems in the field of macroscopic fluid dynamics is discussed. Emphasis is placed on the flow of a viscous, incompressible fluid around a circular cylinder. The following subjects are considered: (1) the flow of a nonviscous fluid around a circular cylinder, (2) the restrictions imposed the stream function by the number of dimensions of space, and (3) the flow past three dimensional bodies in a viscous fluid, particularly past a circular cylinder in the symmetrical case.

  19. Microgravity

    NASA Image and Video Library

    2004-04-15

    Some of the earliest concerns about fluid behavior in microgravity was the management of propellants in spacecraft tanks as they orbited the Earth. On the ground, gravity pulls a fluid to a bottom of a tank (ig, left). In orbit, fluid behavior depends on surface tension, viscosity, wetting effects with the container wall, and other factors. In some cases, a propellant can wet a tank and leave a large gas bubbles in the center (ug, right). Similar probelms can affect much smaller experiments using fluids in small spaces. Photo credit: NASA/Glenn Research Center.

  20. Earthquakes induced by fluid injection and explosion

    USGS Publications Warehouse

    Healy, J.H.; Hamilton, R.M.; Raleigh, C.B.

    1970-01-01

    Earthquakes generated by fluid injection near Denver, Colorado, are compared with earthquakes triggered by nuclear explosion at the Nevada Test Site. Spatial distributions of the earthquakes in both cases are compatible with the hypothesis that variation of fluid pressure in preexisting fractures controls the time distribution of the seismic events in an "aftershock" sequence. We suggest that the fluid pressure changes may also control the distribution in time and space of natural aftershock sequences and of earthquakes that have been reported near large reservoirs. ?? 1970.

  1. SPH modeling of fluid-structure interaction

    NASA Astrophysics Data System (ADS)

    Han, Luhui; Hu, Xiangyu

    2018-02-01

    This work concerns numerical modeling of fluid-structure interaction (FSI) problems in a uniform smoothed particle hydrodynamics (SPH) framework. It combines a transport-velocity SPH scheme, advancing fluid motions, with a total Lagrangian SPH formulation dealing with the structure deformations. Since both fluid and solid governing equations are solved in SPH framework, while coupling becomes straightforward, the momentum conservation of the FSI system is satisfied strictly. A well-known FSI benchmark test case has been performed to validate the modeling and to demonstrate its potential.

  2. Serum and gastric fluid levels of cytokines and nitrates in gastric diseases infected with Helicobacter pylori.

    PubMed

    Mehmet, N; Refik, M; Harputluoglu, M; Ersoy, Y; Aydin, N Engin; Yildirim, B

    2004-04-01

    This case control study presents data on the concentrations of nitrite and nitrate and a variety of pro-inflammatory cytokines such as interleukin-1 beta (IL-1 beta), interleukin-2R (IL-2R), interleukin-6 (IL-6), interleukin-8 (IL-8) and tumor necrosis factor TNF-alpha in gastric fluid and serum. Patients with gastritis, gastric ulcer and gastric cancer are studied and grouped according to infection by Helicobacter pylori. The 208 patients who underwent upper gastrointestinal endoscopic examination were classified as follows; H. pylori-positive gastritis (n = 32), H. pylori-negative gastritis (n = 32), H. pylori-positive ulcers (n = 34), H. pylori-negative ulcers (n = 34), 43 patients with H. pylori-positive gastric cancer in addition to 33 H. pylori-negative healthy control individuals. Gastric fluids and blood samples were taken concomitantly. Cytokines and nitrite and nitrate determinations were attempted as soon as possible after collection of the samples. Nitrite and nitrate levels of serum and gastric fluids of H. pylori-positive gastritis and ulcers were higher than H. pylori-negative gastritis and ulcers. The concentrations of total nitrite and nitrate and cytokines (TNF-alpha, IL-2R, IL-6, and IL-8) in gastric fluids and sera of H. pylori-positive gastric cancer patients were higher than H. pylori-negative control groups. IL-1 beta level was significantly elevated in gastric fluid of infected cancer patients but not in serum. Taken together, the results suggest that an increase in cytokine-NO combination in gastric mucosa previously reported by many studies is not restricted to local infected gastric tissue but also detected in gastric fluid and sera of H. pylori-positive subjects and may have an important role in the pathogenesis and development of common gastric diseases.

  3. Collapse of tall granular columns in fluid

    NASA Astrophysics Data System (ADS)

    Kumar, Krishna; Soga, Kenichi; Delenne, Jean-Yves

    2017-06-01

    Avalanches, landslides, and debris flows are geophysical hazards, which involve rapid mass movement of granular solids, water, and air as a multi-phase system. In order to describe the mechanism of immersed granular flows, it is important to consider both the dynamics of the solid phase and the role of the ambient fluid. In the present study, the collapse of a granular column in fluid is studied using 2D LBM - DEM. The flow kinematics are compared with the dry and buoyant granular collapse to understand the influence of hydrodynamic forces and lubrication on the run-out. In the case of tall columns, the amount of material destabilised above the failure plane is larger than that of short columns. Therefore, the surface area of the mobilised mass that interacts with the surrounding fluid in tall columns is significantly higher than the short columns. This increase in the area of soil - fluid interaction results in an increase in the formation of turbulent vortices thereby altering the deposit morphology. It is observed that the vortices result in the formation of heaps that significantly affects the distribution of mass in the flow. In order to understand the behaviour of tall columns, the run-out behaviour of a dense granular column with an initial aspect ratio of 6 is studied. The collapse behaviour is analysed for different slope angles: 0°, 2.5°, 5° and 7.5°.

  4. An investigation on the motion and deformation of viscoelastic drops descending in another viscoelastic media

    NASA Astrophysics Data System (ADS)

    Davoodi, M.; Norouzi, M.

    2016-10-01

    In the present study, an investigation of the motion and shape deformation of drops is carried out in creeping flow to highlight the effect of viscoelastic properties on the problem. A perturbation method is employed to derive an analytical solution for the general case that both interior and exterior fluids are viscoelastic, both fluids obeying the Giesekus model. An experiment is also performed for the limiting case of an immiscible drop of a 0.03% (w/w) polyacrylamide in an 80:20 glycerol/water solution falling through a viscous Newtonian silicon oil (410 cP polydimethylsiloxane oil) in order to check the accuracy of the analytical solution. It is shown that the addition of elastic properties to the interior fluid may cause a decrease in the terminal velocity of the droplet while an increase in the elastic properties of the exterior fluid results in the opposite behavior and increases the terminal velocity. The well-known spherical shape of creeping drops for Newtonian fluids is modified by elasticity into either prolate or oblate shapes. Using the analytical solution, it is shown that normal stresses play a key role on the final steady-state shape of the drops. To keep the drops spherical in viscoelastic phases, it is shown that the effect of normal stresses on the interior and exterior media can cancel out under certain conditions. The results presented here may be of interest to industries dealing with petroleum and medicine processing, paint and power-plant related fields where knowledge of the shape and terminal velocity of descending droplets is of great importance.

  5. Profile of inhalant users seeking treatment at a de-addiction centre in north India.

    PubMed

    Gupta, Sunil; Nebhinani, Naresh; Basu, Debasish; Mattoo, Surendra Kumar

    2014-05-01

    Inhalants are substances whose chemical vapors are inhaled to produce euphoric, disinhibiting, and exciting effects. Data on inhalant abuse in India are relatively scarce. We report the demographic and clinical profile of inhalant users among the treatment seekers at a Drug De-addiction and Treatment Centre in north India. The records of treatment seekers at the Drug De-addiction and Treatment Centre, over 10 years (2002-2011) were scanned to identify 92 cases reporting inhalant use. Of these 92 cases, the complete record files were available for 87 (94.6%) cases. These case files were reviewed and the relevant data were collected and analyzed. Over the study period of 10 years, the number of cases with inhalant abuse per year rose steadily to peak at 20 cases (4.08% of new cases) in 2006 and then stabilized at 1-3 per cent of new cases annually. Of the 87 cases studied, all were males with a mean age of 18.9±4.12 yr, mean education of 9.8±3.42 yr and mean family income of Rs. 7676±7343.15 (median: Rs. 5000). Majority of subjects were unmarried (89.7%), urban resident (79.3%), and from a nuclear family (78.2%). About half of the subjects were students (50.6%). The most common inhalant used was typewriter correction fluid (73.6%) followed by typewriter diluent fluid (19.5%) and glue (6.9%). The most common reason for initiation was curiosity. The mean age of onset of inhalant use was 16.3±4.22 yr. Most subjects fulfilled the criteria for inhalant dependence (85.1%). Psychiatric co-morbidity and the family history of substance dependence were present in 26.4 and 32.9 per cent subjects, respectively. Majority of the subjects reported drug related problems, occupation and finance being the worst affected. Interpretations & conclusions: Our results showed that the inhalant users were mostly urban youth belonging to middle socio-economic class families. The principal sources of inhalant abuse were the commonly available substances like typewriter correction fluids and majority of the subjects initiated it out of curiosity. Nearly three-fourth of the subjects used some other substance of abuse in addition, tobacco being the most common. In view of associated drug related problems, there is a need for strategies to prevent this emerging health care problem.

  6. Performing Identities in the Classroom: Teaching Jewish Women's Studies

    ERIC Educational Resources Information Center

    Friedman, Kathie; Rosenberg, Karen

    2007-01-01

    Teaching about intersecting, fluid and historically contingent identities has been taken up extensively within the sociology of race, class and gender and women's studies. Oddly, the case of Jewish women has been virtually left out of this robust literature. This article explores the challenges raised through teaching the course "Jewish Women in…

  7. Computational modelling of the flow of viscous fluids in carbon nanotubes

    NASA Astrophysics Data System (ADS)

    Khosravian, N.; Rafii-Tabar, H.

    2007-11-01

    Carbon nanotubes will have extensive application in all areas of nano-technology, and in particular in the field of nano-fluidics, wherein they can be used for molecular separation, nano-scale filtering and as nano-pipes for conveying fluids. In the field of nano-medicine, nanotubes can be functionalized with various types of receptors to act as bio-sensors for the detection and elimination of cancer cells, or be used as bypasses and even neural connections. Modelling fluid flow inside nanotubes is a very challenging problem, since there is a complex interplay between the motion of the fluid and the stability of the walls. A critical issue in the design of nano-fluidic devices is the induced vibration of the walls, due to the fluid flow, which can promote structural instability. It has been established that the resonant frequencies depend on the flow velocity. We have studied, for the first time, the flow of viscous fluids through multi-walled carbon nanotubes, using the Euler-Bernoulli classical beam theory to model the nanotube as a continuum structure. Our aim has been to compute the effect of the fluid flow on the structural stability of the nanotubes, without having to consider the details of the fluid-walls interaction. The variations of the resonant frequencies with the flow velocity are obtained for both unembedded nanotubes, and when they are embedded in an elastic medium. It is found that a nanotube conveying a viscous fluid is more stable against vibration-induced buckling than a nanotube conveying a non-viscous fluid, and that the aspect ratio plays the same role in both cases.

  8. Shock wave-free interface interaction

    NASA Astrophysics Data System (ADS)

    Frolov, Roman; Minev, Peter; Krechetnikov, Rouslan

    2016-11-01

    The problem of shock wave-free interface interaction has been widely studied in the context of compressible two-fluid flows using analytical, experimental, and numerical techniques. While various physical effects and possible interaction patterns for various geometries have been identified in the literature, the effects of viscosity and surface tension are usually neglected in such models. In our study, we apply a novel numerical algorithm for simulation of viscous compressible two-fluid flows with surface tension to investigate the influence of these effects on the shock-interface interaction. The method combines together the ideas from Finite Volume adaptation of invariant domains preserving algorithm for systems of hyperbolic conservation laws by Guermond and Popov and ADI parallel solver for viscous incompressible NSEs by Guermond and Minev. This combination has been further extended to a two-fluid flow case, including surface tension effects. Here we report on a quantitative study of how surface tension and viscosity affect the structure of the shock wave-free interface interaction region.

  9. Delayed sub-aponeurotic fluid collections in infancy: Three cases and a review of the literature

    PubMed Central

    Petraglia, Anthony L.; Moravan, Michael J.; Marky, Andrew H.; Silberstein, Howard J.

    2010-01-01

    Background: Sub-aponeurotic fluid collections (SFCs) in the neonatal period are poorly described in the literature. We describe the occurrence, possible etiologies and treatment of sub-aponeurotic fluid collections following the neonatal period. Case Description: We present 3 cases of previously healthy children who developed soft, fluctuant, extracranial masses several weeks after birth. All 3 children were seen by a pediatric neurosurgeon after parents noticed scalp masses between 5 and 9 weeks of age. All 3 children were found to be otherwise healthy. Two of the children were born via C-section and 1 child was born vaginally. The vaginal delivery was described as difficult and utilized vacuum assist. Scalp electrodes were placed in all 3 children for intensive monitoring during labor. These children received plain skull x-rays to assess for abnormalities, and 2 of the children underwent a non-contrast brain CT scan to better characterize the fluid collection. Plain x-rays and CT scans showed no abnormalities of the skull or ventricles. In both patients who underwent a CT scan, a soft tissue prominence was noted with a Hounsfield unit similar to water. All cases resolved between 5 and 9 weeks after initial presentation, with no long-term sequelae. Conclusion: SFCs presenting after the neonatal period are usually associated with benign soft tissue swellings. Use of fetal scalp electrodes has been shown to cause cerebrospinal fluid (CSF) leakage in the neonatal period and may result in delayed SFC. This condition is benign, and the recommended course of treatment is conservative management. PMID:20847915

  10. The Computational Fluid Dynamics Rupture Challenge 2013—Phase I: prediction of rupture status in intracranial aneurysms.

    PubMed

    Janiga, G; Berg, P; Sugiyama, S; Kono, K; Steinman, D A

    2015-03-01

    Rupture risk assessment for intracranial aneurysms remains challenging, and risk factors, including wall shear stress, are discussed controversially. The primary purpose of the presented challenge was to determine how consistently aneurysm rupture status and rupture site could be identified on the basis of computational fluid dynamics. Two geometrically similar MCA aneurysms were selected, 1 ruptured, 1 unruptured. Participating computational fluid dynamics groups were blinded as to which case was ruptured. Participants were provided with digitally segmented lumen geometries and, for this phase of the challenge, were free to choose their own flow rates, blood rheologies, and so forth. Participants were asked to report which case had ruptured and the likely site of rupture. In parallel, lumen geometries were provided to a group of neurosurgeons for their predictions of rupture status and site. Of 26 participating computational fluid dynamics groups, 21 (81%) correctly identified the ruptured case. Although the known rupture site was associated with low and oscillatory wall shear stress, most groups identified other sites, some of which also experienced low and oscillatory shear. Of the 43 participating neurosurgeons, 39 (91%) identified the ruptured case. None correctly identified the rupture site. Geometric or hemodynamic considerations favor identification of rupture status; however, retrospective identification of the rupture site remains a challenge for both engineers and clinicians. A more precise understanding of the hemodynamic factors involved in aneurysm wall pathology is likely required for computational fluid dynamics to add value to current clinical decision-making regarding rupture risk. © 2015 by American Journal of Neuroradiology.

  11. Incidence, risk factors, management and outcomes of amniotic-fluid embolism: a population-based cohort and nested case-control study.

    PubMed

    Fitzpatrick, K E; Tuffnell, D; Kurinczuk, J J; Knight, M

    2016-01-01

    To describe the incidence, risk factors, management and outcomes of amniotic-fluid embolism (AFE) over time. A population-based cohort and nested case-control study using the UK Obstetric Surveillance System (UKOSS). All UK hospitals with obstetrician-led maternity units. All women diagnosed with AFE in the UK between February 2005 and January 2014 (n = 120) and 3839 control women. Prospective case and control identification through UKOSS monthly mailing. Amniotic-fluid embolism, maternal death or permanent neurological injury. The total and fatal incidence of AFE, estimated as 1.7 and 0.3 per 100 000, respectively, showed no significant temporal trend over the study period and there was no notable temporal change in risk factors for AFE. Twenty-three women died (case fatality 19%) and seven (7%) of the surviving women had permanent neurological injury. Women who died or had permanent neurological injury were more likely to present with cardiac arrest (83% versus 33%, P < 0.001), be from ethnic-minority groups (adjusted odds ratio [OR] 2.85, 95% confidence interval [95% CI] 1.02-8.00), have had a hysterectomy (unadjusted OR 2.49, 95% CI 1.02-6.06), had a shorter time interval between the AFE event and when the hysterectomy was performed (median interval 77 minutes versus 248 minutes, P = 0.0315), and were less likely to receive cryoprecipitate (unadjusted OR 0.30, 95% CI 0.11-0.80). There is no evidence of a temporal change in the incidence of or risk factors for AFE. Further investigation is needed to establish whether earlier treatments can reverse the cascade of deterioration leading to severe outcomes. © 2015 The Authors. BJOG An International Journal of Obstetrics and Gynaecology published by John Wiley & Sons Ltd on behalf of Royal College of Obstetricians and Gynaecologists.

  12. Pine needle abortion biomarker detected in bovine fetal fluids.

    PubMed

    Snider, Douglas B; Gardner, Dale R; Janke, Bruce H; Ensley, Steven M

    2015-01-01

    Pine needle abortion is a naturally occurring condition in free-range cattle caused by the consumption of pine needles from select species of cypress, juniper, pine, and spruce trees. Confirmatory diagnosis of pine needle abortion has previously relied on a combined case history of pine needle consumption and detection of isocupressic acid in a sample from the dam. Stable metabolites of isocupressic acid include agathic acid, dihydroagathic acid, and tetrahydroagathic acid, which have been shown to be present in the serum of mature animals for a few days following consumption of pine needles. As maternal serum is infrequently submitted for diagnosis of cattle abortions, a diagnostic assay capable of confirming isocupressic acid exposure in other matrices would be desirable. To the authors' knowledge, no previous investigations have indicated whether these stable metabolites of isocupressic acid cross the placenta or are detectable in fetal tissues. Therefore, the presence of agathic acid, dihydroagathic acid, and tetrahydroagathic acid was evaluated using gas chromatography-mass spectroscopy on fetal thoracic fluid and stomach contents collected from 2 aborted bovine fetuses with a recent herd history of pine needle consumption by the dams and a subsequent abortion outbreak in the herd. Only tetrahydroagathic acid was detected in the fetal thoracic fluid and fetal stomach contents. The current study encourages diagnosticians to collect fetal thoracic fluids to permit the detection of tetrahydroagathic acid in cases of suspected pine needle abortion. © 2014 The Author(s).

  13. Modeling the Conducting Stably-Stratified Layer of the Earth's Core

    NASA Astrophysics Data System (ADS)

    Petitdemange, L.; Philidet, J.; Gissinger, C.

    2017-12-01

    Observations of the Earth magnetic field as well as recent theoretical works tend to show that the Earth's outer liquid core is mostly comprised of a convective zone in which the Earth's magnetic field is generated - likely by dynamo action -, but also features a thin, stably stratified layer at the top of the core.We carry out direct numerical simulations by modeling this thin layer as an axisymmetric spherical Couette flow for a stably stratified fluid embedded in a dipolar magnetic field. The dynamo region is modeled by a conducting inner core rotating slightly faster than the insulating mantle due to magnetic torques acting on it, such that a weak differential rotation (low Rossby limit) can develop in the stably stratified layer.In the case of a non-stratified fluid, the combined action of the differential rotation and the magnetic field leads to the well known regime of `super-rotation', in which the fluid rotates faster than the inner core. Whereas in the classical case, this super-rotation is known to vanish in the magnetostrophic limit, we show here that the fluid stratification significantly extends the magnitude of the super-rotation, keeping this phenomenon relevant for the Earth core. Finally, we study how the shear layers generated by this new state might give birth to magnetohydrodynamic instabilities or waves impacting the secular variations or jerks of the Earth's magnetic field.

  14. Evaluation of a commercial rubella IgM assay for use on oral fluid samples for diagnosis and surveillance of congenital rubella syndrome and postnatal rubella.

    PubMed

    Vijaylakshmi, P; Muthukkaruppan, V R; Rajasundari, A; Korukluoglu, G; Nigatu, W; L A Warrener; Samuel, D; Brown, D W G

    2006-12-01

    Clinical diagnosis (surveillance) of rubella is unreliable and laboratory confirmation is essential. Detection of virus specific IgM in serum is the most commonly used method. However, the use of serum necessitates the drawing of blood, either through venipuncture or finger/heel prick, which can be difficult in young babies. Oral fluid samples have proved useful as an alternative, less invasive sample for virus specific IgM detection however until recently no commercial rubella IgM tests were available, restricting the usefulness of this approach. To evaluate the performance of the Microimmune Rubella IgM capture EIA using oral fluid samples from outbreaks as well as in cases of suspected congenital rubella syndrome (CRS). Paired serum and oral fluids were collected from cases during a rubella outbreak in three provinces in Turkey. Matched serum and oral fluid samples were collected from children with suspected CRS in an active surveillance programme at the Aravind Eye Hospital in South India. Serum samples were collected as part of the measles surveillance programme in Ethiopia. On serum samples the sensitivity and specificity of the Microimmune Rubella IgM capture EIA compared to Behring Enzygnost rubella IgM test was 96.9% (62/64; 95% CI 94.2-100%) and 100% (53/53; 95% CI 93.2-100%). On oral fluids compared to matched Behring results on serum the sensitivity was 95.5% (42/44; 95% CI 84.5-99.4%). The sensitivity and specificity of Microimmune Rubella IgM capture EIA on oral fluids from suspected CRS cases compared to serum results using Behring Enzygnost IgM assay was 100% (95% CI 84.5-100%) and 100% (95% CI 95.8-100.0%) respectively. Microimmune Rubella IgM capture EIA has adequate performance for diagnosis and surveillance of rubella in outbreak using either serum or oral fluid specimens.

  15. Stratified rotating Boussinesq equations in geophysical fluid dynamics: Dynamic bifurcation and periodic solutions

    NASA Astrophysics Data System (ADS)

    Hsia, Chun-Hsiung; Ma, Tian; Wang, Shouhong

    2007-06-01

    The main objective of this article is to study the dynamics of the stratified rotating Boussinesq equations, which are a basic model in geophysical fluid dynamics. First, for the case where the Prandtl number is greater than 1, a complete stability and bifurcation analysis near the first critical Rayleigh number is carried out. Second, for the case where the Prandtl number is smaller than 1, the onset of the Hopf bifurcation near the first critical Rayleigh number is established, leading to the existence of nontrivial periodic solutions. The analysis is based on a newly developed bifurcation and stability theory for nonlinear dynamical systems (both finite and infinite dimensional) by two of the authors [T. Ma and S. Wang, Bifurcation Theory and Applications, World Scientific Series on Nonlinear Sciences Vol. 53 (World Scientific, Singapore, 2005)].

  16. Analysis of the archaeal sub-seafloor community at Suiyo Seamount on the Izu-Bonin Arc.

    PubMed

    Hara, Kurt; Kakegawa, Takeshi; Yamashiro, Kan; Maruyama, Akihiko; Ishibashi, Jun-Ichiro; Marumo, Katsumi; Urabe, Tetsuro; Yamagishi, Akihiko

    2005-01-01

    A sub-surface archaeal community at the Suiyo Seamount in the Western Pacific Ocean was investigated by 16S rRNA gene sequence and whole-cell in situ hybridization analyses. In this study, we drilled and cased holes at the hydrothermal area of the seamount to minimize contamination of the hydrothermal fluid in the sub-seafloor by penetrating seawater. PCR clone analysis of the hydrothermal fluid samples collected from a cased hole indicated the presence of chemolithoautotrophic primary biomass producers of Archaeoglobales and the Methanococcales-related archaeal HTE1 group, both of which can utilize hydrogen as an electron donor. We discuss the implication of the microbial community on the early history of life and on the search for extraterrestrial life. c2005 COSPAR. Published by Elsevier Ltd. All rights reserved.

  17. A summary of special coatings projects conducted in support of the Die Casting Program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Selle, J.E.

    1988-09-12

    The usefulness of various kinds of coatings to the die casting program has been studied. This work includes heat transfer and fluid flow calculations, as well as experimental work, to examine the feasibility and characteristics of various types of coatings. Calculations include the effect of surface roughness on fluid flow, conductance as a function of coating thickness, conductivity as a function of coating porosity, and solidification and possible remelting of microspheres of metal. In each case, the model is described and the results are presented. Experimental work involved evaluating the relative insulating value of various coatings and an analysis ofmore » commercial flame-sprayed coatings, low-density coatings, and release coatings. In each case, description of the experimental arrangement is given and the results are described. 5 refs., 28 figs., 6 tabs.« less

  18. Visualization of various working fluids flow regimes in gravity heat pipe

    NASA Astrophysics Data System (ADS)

    Nemec, Patrik

    Heat pipe is device working with phase changes of working fluid inside hermetically closed pipe at specific pressure. The phase changes of working fluid from fluid to vapour and vice versa help heat pipe to transport high heat flux. Amount of heat flux transferred by heat pipe, of course depends on kind of working fluid. The article deal about visualization of various working fluids flow regimes in glass gravity heat pipe by high speed camera and processes casing inside during heat pipe operation. Experiment working fluid flow visualization is performed with two glass heat pipes with different inner diameter (13 mm and 22 mm) filled with water, ethanol and fluorinert FC 72. The working fluid flow visualization explains the phenomena as a working fluid boiling, nucleation of bubbles, and vapour condensation on the wall, vapour and condensate flow interaction, flow down condensate film thickness on the wall occurred during the heat pipe operation.

  19. Bartter syndrome prenatal diagnosis based on amniotic fluid biochemical analysis.

    PubMed

    Garnier, Arnaud; Dreux, Sophie; Vargas-Poussou, Rosa; Oury, Jean-François; Benachi, Alexandra; Deschênes, Georges; Muller, Françoise

    2010-03-01

    Bartter syndrome is an autosomic recessive disease characterized by severe polyuria and sodium renal loss. The responsible genes encode proteins involved in electrolyte tubular reabsorption. Prenatal manifestations, mainly recurrent polyhydramnios because of fetal polyuria, lead to premature delivery. After birth, polyuria leads to life-threatening dehydration. Prenatal genetic diagnosis needs an index case. The aim of this study was to analyze amniotic fluid biochemistry for the prediction of Bartter syndrome. We retrospectively studied 16 amniotic fluids of Bartter syndrome-affected fetuses diagnosed after birth, only six of them being genetically proven. We assayed total proteins, alpha-fetoprotein, and electrolytes and defined a Bartter index corresponding to the multiplication of total protein and of alpha-fetoprotein. Results were compared with two control groups matched for gestational age-non-Bartter polyhydramnios (n = 30) and nonpolyhydramnios (n = 60). In Bartter syndrome, we observed significant differences (p < 0.0001) for protein amniotic fluid levels when compared with the two control groups (1.55 g/L, 3.9 g/L, and 5.2 g/L, respectively) and low Bartter index (0.16, 0.82, and 1.0, respectively). No statistical difference was observed for electrolytes. In conclusion, Bartter syndrome can be prenatally suspected on amniotic fluid biochemistry (sensitivity 93% and specificity 100%), allowing appropriate management before and after birth.

  20. MicroRNA Changes in Cerebrospinal Fluid After Subarachnoid Hemorrhage.

    PubMed

    Bache, Søren; Rasmussen, Rune; Rossing, Maria; Laigaard, Finn Pedersen; Nielsen, Finn Cilius; Møller, Kirsten

    2017-09-01

    Delayed cerebral ischemia (DCI) accounts for a major part of the morbidity and mortality after aneurysmal subarachnoid hemorrhage (SAH). MicroRNAs (miRNAs) are pathophysiologically involved in acute cerebral ischemia. This study compared miRNA profiles in cerebrospinal fluid from neurologically healthy patients, as well as SAH patients with and without subsequent development of DCI. In a prospective case-control study of SAH patients treated with external ventricular drainage and neurologically healthy patients, miRNA profiles in cerebrospinal fluid were screened and validated using 2 different high-throughput real-time quantification polymerase chain reaction techniques. The occurrence of DCI was documented in patient charts and subsequently reviewed independently by 2 physicians. MiRNA profiles from 27 SAH patients and 10 neurologically healthy patients passed quality control. In the validation, 66 miRNAs showed a relative increase in cerebrospinal fluid from SAH patients compared with neurologically healthy patients ( P <0.001); 2 (miR-21 and miR-221) showed a relative increase in SAH patients with DCI compared with those without ( P <0.05) in both the screening and validation. SAH is associated with marked changes in the cerebrospinal fluid miRNA profile. These changes could be associated to the development of DCI. URL: http://www.clinicaltrials.gov. Unique identifier: NCT01791257. © 2017 The Authors.

Top