DOE Office of Scientific and Technical Information (OSTI.GOV)
Yinfa, Ma.
Thin-layer chromatography (TLC) is a broadly applicable separation technique. It offers many advantages over high performance liquid chromatography (HPLC), such as easily adapted for two-dimensional separation, for whole-column'' detection and for handling multiple samples, etc. However, due to its draggy development of detection techniques comparing with HPLC, TLC has not received the attention it deserves. Therefore, exploring new detection techniques is very important to the development of TLC. It is the principal of this dissertation to present a new detection method for TLC -- indirect fluorometric detection method. This detection technique is universal sensitive, nondestructive, and simple. This will bemore » described in detail from Sections 1 through Section 5. Section 1 and 3 describe the indirect fluorometric detection of anions and nonelectrolytes in TLC. In Section 2, a detection method for cations based on fluorescence quenching of ethidium bromide is presented. In Section 4, a simple and interesting TLC experiment is designed, three different fluorescence detection principles are used for the determination of caffeine, saccharin and sodium benzoate in beverages. A laser-based indirect fluorometric detection technique in TLC is developed in Section 5. Section 6 is totally different from Sections 1 through 5. An ultrasonic effect on the separation of DNA fragments in agarose gel electrophoresis is investigated. 262 refs.« less
Spectrometric microbiological analyzer
NASA Astrophysics Data System (ADS)
Schlager, Kenneth J.; Meissner, Ken E.
1996-04-01
Currently, there are four general approaches to microbiological analysis, i.e., the detection, identification and quantification of micro-organisms: (1) Traditional culturing and staining procedures, metabolic fermentations and visual morphological characteristics; (2) Immunological approaches employing microbe-specific antibodies; (3) Biotechnical techniques employing DNA probes and related genetic engineering methods; and (4) Physical measurement techniques based on the biophysical properties of micro-organisms. This paper describes an instrumentation development in the fourth of the above categories, physical measurement, that uses a combination of fluorometric and light scatter spectra to detect and identify micro-organisms at the species level. A major advantage of this approach is the rapid turnaround possible in medical diagnostic or water testing applications. Fluorometric spectra serve to define the biochemical characteristics of the microbe, and light scatter spectra the size and shape morphology. Together, the two spectra define a 'fingerprint' for each species of microbe for detection, identification and quantification purposes. A prototype instrument has been developed and tested under NASA sponsorship based on fluorometric spectra alone. This instrument demonstrated identification and quantification capabilities at the species level. The paper reports on test results using this instrument, and the benefits of employing a combination of fluorometric and light scatter spectra.
Fluorometric procedures for dye tracing
Wilson, James F.; Cobb, Ernest D.; Kilpatrick, F.A.
1986-01-01
This manual describes the current fluorometric procedures used by the U.S. Geological Survey in dye tracer studies such as time of travel, dispersion, reaeration, and dilution-type discharge measurements. The advantages of dye tracing are (1) low detection and measurement limits and (2) simplicity and accuracy in measuring dye tracer concentrations using fluorometric techniques. The manual contains necessary background information about fluorescence, dyes, and fluorometers and a description of fluorometric operation and calibration procedures as a guide for laboratory and field use. The background information should be useful to anyone wishing to experiment with dyes, fluorometer components, or procedures different from those described. In addition, a brief section on aerial photography is included because of its possible use to supplement ground-level fluorometry.
Fluorometric procedures for dye tracing
Wilson, James F.
1968-01-01
This manual describes the current fluorometric procedures used by the U.S. Geological Survey in dye tracer studies such as time of travel, dispersion, reaeration, and dilution-type discharge measurements. The advantages of dye tracing are (1) low detection and measurement limits and (2) simplicity and accuracy in measuring dye tracer concentrations using fluorometric techniques. The manual contains necessary background information about fluorescence, dyes, and fluorometers and a description of fluorometric operation and calibration procedures as a guide for laboratory and field use. The background information should be useful to anyone wishing to experiment with dyes, fluorometer components, or procedures different from those described. In addition, a brief section on aerial photography is included because of its possible use to supplement ground-level fluorometry.
Fluorometric procedures for dye tracing
Wilson, James E.; Cobb, Ernest D.; Kilpatrick, Frederick A.
1984-01-01
This manual describes the current fluorometric procedures used by the U.S. Geological Survey in dye tracer studies such as time of travel, dispersion, reaeration, and dilution-type discharge measurements. The outstanding characteristics of dye tracing are: (1) the low detection and measurement limits, and (2) the simplicity and accuracy of measuring dye tracer concentrations using fluorometric techniques. The manual contains necessary background information about fluorescence, dyes, and fluorometers and a description of fluorometric operation and calibration procedures as a general guide for laboratory and field use. The background information should be useful to anyone wishing to experiment with dyes, fluorometer components, or procedures different from those described. In addition, a brief section is included on aerial photography because of its possible use to supplement ground-level fluorometry.
Horka, Marie; Ruzicka, Filip; Horký, Jaroslav; Holá, Veronika; Slais, Karel
2006-12-15
The nonionogenic pyrene-based tenside, poly(ethylene glycol) pyrenebutanoate, was prepared and applied in capillary isoelectric focusing with fluorometric detection. This dye was used here as a buffer additive in capillary isoelectric focusing for a dynamic modification of the sample of proteins and microorganisms. The values of the isoelectric points of the labeled bioanalytes were calculated with use of the fluorescent pI markers and were found comparable with pI of the native compounds. The mixed cultures of proteins and microorganisms, Escherichia coli CCM 3954, Staphylococcus epidermidis CCM 4418, Proteus vulgaris, Enterococcus faecalis CCM 4224, and Stenotrophomonas maltophilia, the strains of the yeast cells, Candida albicans CCM 8180, Candida krusei, Candida parapsilosis, Candida glabrata, Candida tropicalis, and Saccharomyces cerevisiae were reproducibly focused and separated by the suggested technique. Using UV excitation for the on-column fluorometric detection, the minimum detectable amount was down to 10 cells injected on the separation capillary.
NASA Technical Reports Server (NTRS)
Bonner, J.
1976-01-01
A highly sensitive fluorometric technique is developed for the determination of biological and geo-organic compounds in ancient sediments and extraterrestrial samples. This technique is used to establish chemical evidence for fossil pigments in an extraterrestrial sample. Also developed is a highly sensitive and specific fluorometric method for the determination of total primary amine nitrogen in soil samples.
DOT National Transportation Integrated Search
1971-04-01
An automated fluorometric trihydroxyindole procedure is described for the measurement of norepinephrine (NE) and epinephrine (E) in blood plasma or urine. The method employs conventional techniques for isolation of the catecholamines by alumina colum...
Tracey, Matthew P; Pham, Dianne; Koide, Kazunori
2015-07-21
Neither palladium nor platinum is an endogenous biological metal. Imaging palladium in biological samples, however, is becoming increasingly important because bioorthogonal organometallic chemistry involves palladium catalysis. In addition to being an imaging target, palladium has been used to fluorometrically image biomolecules. In these cases, palladium species are used as imaging-enabling reagents. This review article discusses these fluorometric methods. Platinum-based drugs are widely used as anticancer drugs, yet their mechanism of action remains largely unknown. We discuss fluorometric methods for imaging or quantifying platinum in cells or biofluids. These methods include the use of chemosensors to directly detect platinum, fluorescently tagging platinum-based drugs, and utilizing post-labeling to elucidate distribution and mode of action.
Xu, Kefeng; Chen, Zhonghui; Zhou, Ling; Zheng, Ou; Wu, Xiaoping; Guo, Longhua; Qiu, Bin; Lin, Zhenyu; Chen, Guonan
2015-01-06
A fluorometric method for pyrophosphatase (PPase) activity detection was developed based on click chemistry. Cu(II) can coordinate with pyrophosphate (PPi), the addition of pyrophosphatase (PPase) into the above system can destroy the coordinate compound because PPase catalyzes the hydrolysis of PPi into inorganic phosphate and produces free Cu(II), and free Cu(II) can be reduced by sodium ascorbate (SA) to form Cu(I), which in turn initiates the ligating reaction between nonfluorescent 3-azidocoumarins and terminal alkynes to produce a highly fluorescent triazole complex, based on which, a simple and sensitive turn on fluorometric method for PPase can be developed. The fluorescence intensity of the system has a linear relationship with the logarithm of the PPase concentration in the range of 0.5 and 10 mU with a detection limit down to 0.2 mU (S/N = 3). This method is cost-effective and convenient without any labels or complicated operations. The proposed system was applied to screen the potential PPase inhibitor with high efficiency. The proposed method can be applied to diagnosis of PPase-related diseases.
Ge, Jia; Bai, Dong-Mei; -Geng, Xin; Hu, Ya-Lei; Cai, Qi-Yong; Xing, Ke; Zhang, Lin; Li, Zhao-Hui
2018-01-10
The authors describe a fluorometric method for the quantitation of nucleic acids by combining (a) cycled strand displacement amplification, (b) the unique features of the DNA probe SYBR Green, and (c) polydopamine nanotubes. SYBR Green undergoes strong fluorescence enhancement upon intercalation into double-stranded DNA (dsDNA). The polydopamine nanotubes selectively adsorb single-stranded DNA (ssDNA) and molecular beacons. In the absence of target DNA, the molecular beacon, primer and SYBR Green are adsorbed on the surface of polydopamine nanotubes. This results in quenching of the fluorescence of SYBR Green, typically measured at excitation/emission wavelengths of 488/518 nm. Upon addition of analyte (target DNA) and polymerase, the stem of the molecular beacon is opened so that it can bind to the primer. This triggers target strand displacement polymerization, during which dsDNA is synthesized. The hybridized target is then displaced due to the strand displacement activity of the polymerase. The displaced target hybridizes with another molecular beacon. This triggers the next round of polymerization. Consequently, a large amount of dsDNA is formed which is detected by addition of SYBR Green. Thus, sensitive and selective fluorometric detection is realized. The fluorescent sensing strategy shows very good analytical performances towards DNA detection, such as a wide linear range from 0.05 to 25 nM with a low limit of detection of 20 pM. Graphical abstract Schematic of a fluorometric strategy for highly sensitive and selective determination of nucleic acids by combining strand displacement amplification and the unique features of SYBR Green I (SG) and polydopamine nanotubes.
Magiati, Maria; Sevastou, Areti; Kalogianni, Despina P
2018-06-04
A fluorometric lateral flow assay has been developed for the detection of nucleic acids. The fluorophores phycoerythrin (PE) and fluorescein isothiocyanate (FITC) were used as labels, while a common digital camera and a colored vinyl-sheet, acting as a cut-off optical filter, are used for fluorescence imaging. After DNA amplification by polymerase chain reaction (PCR), the biotinylated PCR product is hybridized to its complementary probe that carries a poly(dA) tail at 3΄ edge and then applied to the lateral flow strip. The hybrids are captured to the test zone of the strip by immobilized poly(dT) sequences and detected by streptavidin-fluorescein and streptavidin-phycoerythrin conjugates, through streptavidin-biotin interaction. The assay is widely applicable, simple, cost-effective, and offers a large multiplexing potential. Its performance is comparable to assays based on the use of streptavidin-gold nanoparticles conjugates. As low as 7.8 fmol of a ssDNA and 12.5 fmol of an amplified dsDNA target were detectable. Graphical abstract Schematic presentation of a fluorometric lateral flow assay based on fluorescein and phycoerythrin fluorescent labels for the detection of single-stranded (ssDNA) and double-stranded DNA (dsDNA) sequences and using a digital camera readout. SA: streptavidin, BSA: Bovine Serum Albumin, B: biotin, FITC: fluorescein isothiocyanate, PE: phycoerythrin, TZ: test zone, CZ: control zone.
Saito, Yoshio; Kugenuma, Kenji; Tanaka, Makiko; Suzuki, Azusa; Saito, Isao
2012-06-01
We demonstrated an intriguing method to discriminate adenine by incident appearance of an intense new emission via exciplex formation in hybridization of target DNA with newly designed fluorescent 8-arylethynylated deoxyguanosine derivatives. We described the synthesis of such highly electron donating fluorescent guanosine derivatives and their incorporation into DNA oligomers which may be used for the structural study and the fluorometric analysis of nucleic acids. Copyright © 2012 Elsevier Ltd. All rights reserved.
Interaction of diazepam with surfactants. Spectrophotometric and spectrofluorometric study
NASA Astrophysics Data System (ADS)
De La Guardia, M.; Rodilla, F.
1986-03-01
The interaction of diazepam with non-ionic, anionic and cationic surfactants has been studied spectrophotometrically and fluorometrically. It has been verified that the absorption spectrum of diazepam is not modified in micellar medium. However, a dramatic five-fold increase in fluorescence sensitivity is observed in the presence of sodium lauryl sulphate (SDS). The experimental conditions, temperature, pH and surfactant concentration have been optimized to improve the fluorometric determination of diazepam and a detection limit of 0,04 ppmhas been obtained.
Taga, C; Tsuji, M; Nakajima, T
1989-05-01
A reversed phase HPLC method with fluorometric detection for the analysis of beta-phenylethylamine has been developed using p-methoxyphenylethylamine as an internal standard. Two columns, containing 200 microL of Dowex 50-X8 and Amberlite CG-50 respectively, were used to prepare a fraction containing beta-phenylethylamine. The recoveries of beta-phenylethylamine and p-methoxyphenylethylamine were 53.9 +/- 9.4% and 68.1 +/- 12.4%, respectively, and elution profile of p-methoxyphenylethylamine was sufficiently well correlated with that of beta-phenylethylamine. Regional distributions of beta-phenylethylamine in rat and mouse brains were determined. The highest concentrations were found in hypothalamus and hippocampus in both animals.
Optical sensors for application in intelligent food-packaging technology
NASA Astrophysics Data System (ADS)
McEvoy, Aisling K.; Von Bueltzingsloewen, Christoph; McDonagh, Colette M.; MacCraith, Brian D.; Klimant, Ingo; Wolfbeis, Otto S.
2003-03-01
Modified Atmosphere Packaged (MAP) food employs a protective gas mixture, which normally contains selected amounts of carbon dioxide (CO2) and oxygen (O2), in order to extend the shelf life of food. Conventional MAP analysis of package integrity involves destructive sampling of packages followed by carbon dioxide and oxygen detection. For quality control reasons, as well as to enhance food safety, the concept of optical on-pack sensors for monitoring the gas composition of the MAP package at different stages of the distribution process is very attractive. The objective of this work was to develop printable formulations of oxygen and carbon dioxide sensors for use in food packaging. Oxygen sensing is achieved by detecting the degree of quenching of a fluorescent ruthenium complex entrapped in a sol-gel matrix. In particular, a measurement technique based on the quenching of the fluorescence decay time, phase fluorometric detection, is employed. A scheme for detecting CO2 has been developed which is compatible with the oxygen detection scheme. It is fluorescence-based and uses the pH-sensitive 8-hydroxypyrene-1,3,6-trisulfonic acid (HPTS) indicator dye encapsulated in an organically modified silica (ORMOSIL) glass matrix. Dual Luminophore Referencing (DLR) has been employed as an internal referencing scheme, which provides many of the advantages of lifetime-based fluorometric methods. Oxygen cross-sensitivity was minimised by encapsulating the reference luminophore in dense sol-gel microspheres. The sensor performance compared well with standard methods for both oxygen and carbon dioxide detection. The results of preliminary on-pack print trials are presented and a preliminary design of an integrated dual gas optical read-out device is discussed.
Laser fluorometric analysis of plants for uranium exploration
Harms, T.F.; Ward, F.N.; Erdman, J.A.
1981-01-01
A preliminary test of biogeochemical exploration for locating uranium occurrences in the Marfa Basin, Texas, was conducted in 1978. Only 6 of 74 plant samples (mostly catclaw mimosa, Mimosa biuncifera) contained uranium in amounts above the detection limit (0.4 ppm in the ash) of the conventional fluorometric method. The samples were then analyzed using a Scintrex UA-3 uranium analyzer* * Use of trade names in this paper is for descriptive purposes only and does not constitute endorsement by the U.S. Geological Survey. - an instrument designed for direct analysis of uranium in water, and which can be conveniently used in a mobile field laboratory. The detection limit for uranium in plant ash (0.05 ppm) by this method is almost an order of magnitude lower than with the fluorometric conventional method. Only 1 of the 74 samples contained uranium below the detection limit of the new method. Accuracy and precision were determined to be satisfactory. Samples of plants growing on mineralized soils and nonmineralized soils show a 15-fold difference in uranium content; whereas the soils themselves (analyzed by delayed neutron activation analysis) show only a 4-fold difference. The method involves acid digestion of ashed tissue, extraction of uranium into ethyl acetate, destruction of the ethyl acetate, dissolution of the residue in 0.005% nitric acid, and measurement. ?? 1981.
OPTIMIZATION OF THE WASH-OFF METHOD FOR MEASURING AEROSOL CONCENTRATIONS
Using the fluorescence-washing technique, oleic acid particles tagged with uranine were extracted and analyzed fluorometrically. The possible sources of errors in the technique were evaluated in this study. First, the sensitivity of uranine fluorescence in different solutions ...
Wang, Ping; Wu, Tun-Hua; Zhang, Yong
2016-01-01
Metal-enhanced fluorescence (MEF) has exhibited promise for applications in fluorometric assays. The effects of silver nanoparticles (AgNP) on the fluorescence behaviours of tetracycline hydrochloride (TCH) and chlortetracycline hydrochloride (CTC) in aqueous solutions were investigated. The experimental results demonstrated that the fluorescence intensities of each tetracycline in water solutions were greatly enhanced by AgNP through the MEF effect. In addition, a novel silver nanoparticle-enhanced fluorometric method was established for the direct determination of TCH and CTC in aqueous solutions. Under optimum experimental conditions, the linear dynamic ranges for the determination of TCH and CTC in aqueous solutions varied from 0.10 to 6.0 mg L(-1) and 0.050 to 3.0 mg L(-1) with detection limits of 0.63 µg L(-1) and 0.19 µg L(-1), respectively, and with the relative standard deviation of less than 1.9% (n=9). The experimental recovery results for the determination of TCH and CTC in aqueous solutions ranged from 93-106% and 95-104%, respectively. Compared with the established method without the addition of AgNP, the limits of quantitation of the silver nanoparticle-enhanced fluorometric method were approximately 5-fold lower for TCH and 3-fold lower for CTC. Moreover, the newly established silver nanoparticle-enhanced fluorometric method was successfully applied to the direct determination of TCH and CTC in pharmaceutical preparations. Copyright © 2015 Elsevier B.V. All rights reserved.
Wad, N; Krämer, G
1998-01-23
Serum concentrations of the antiepileptic drug gabapentin (GBP) are usually determined by high-performance liquid chromatography (HPLC) using UV photometric detection after pre-column derivatization with 2,4,6-trinitrobenzenesulphonic acid. Vigabatrin levels in serum are determined by HPLC using fluorescence detection. Like vigabatrin (VGB), gabapentin has also a primary amine group that easily reacts with o-phthaldialdehyde reagent and produces a fluorescing substance. By the use of fluorometric detection, GBP can be determined more simply, sensitively and simultaneously with VGB. The day-to-day coefficient of variation for the determination of GBP in a pooled serum was 4.0% (n=17; serum concentration, 13.8 micromol/l) and forVGB was 3.1% (n=21; serum concentration, 26.4 micromol/l). The lower limit of detection is 0.5 micromol/l for both drugs and the method is linear up to 500 micromol/l for GBP and 1300 micromol/l for VGB.
Inpota, Prawpan; Strzelak, Kamil; Koncki, Robert; Sripumkhai, Wisaroot; Jeamsaksiri, Wutthinan; Ratanawimarnwong, Nuanlaor; Wilairat, Prapin; Choengchan, Nathawut; Chantiwas, Rattikan; Nacapricha, Duangjai
2018-01-01
A microfluidic method with front-face fluorometric detection was developed for the determination of total inorganic iodine in drinking water. A polydimethylsiloxane (PDMS) microfluidic device was employed in conjunction with the Sandell-Kolthoff reaction, in which iodide catalyzed the redox reaction between Ce(IV) and As(III). Direct alignment of an optical fiber attached to a spectrofluorometer was used as a convenient detector for remote front-face fluorometric detection. Trace inorganic iodine (IO 3 - and I - ) present naturally in drinking water was measured by on-line conversion of iodate to iodide for determination of total inorganic iodine. On-line conversion efficiency of iodate to iodide using the microfluidic device was investigated. Excellent conversion efficiency of 93 - 103% (%RSD = 1.6 - 11%) was obtained. Inorganic iodine concentrations in drinking water samples were measured, and the results obtained were in good agreement with those obtained by an ICP-MS method. Spiked sample recoveries were in the range of 86%(±5) - 128%(±8) (n = 12). Interference of various anions and cations were investigated with tolerance limit concentrations ranging from 10 -6 to 2.5 M depending on the type of ions. The developed method is simple and convenient, and it is a green method for iodine analysis, as it greatly reduces the amount of toxic reagent consumed with reagent volumes in the microfluidic scale.
Dubber, Donata; Gill, Laurence W
2017-12-15
Rural river catchments are impacted by diffuse pollution sources from agricultural practices and on-site domestic wastewater treatment systems (DWWTS), mainly septic tanks. Methods that can distinguish between contamination sources will significantly increase water management efficiency as they will allow for the development and application of targeted remediation measures. Fluorescent whitening compounds (FWC), are used as optical brighteners in laundry detergents and enter the environment through the discharge of domestic wastewater effluents. Due to their human specific source and potential simple fluorometric measurement this represents a very attractive method to be used by state monitoring agencies. In this study the suitability of FWCs as chemical indicators for human faecal contamination has been investigated in rural Irish catchments. It was found that no quantitative measurements are possible for FWCs in natural waters when using simple fluorometric methods. Hence a simple presence/absence approach needs to be applied. The detectability of FWCs was quantified and found to decrease with higher organic matter content of the river water which has its own fluorescence. This enabled the establishment of equations to predict detection limits and assess the method's suitability for individual catchments based on organic matter concentrations. Furthermore a modified photodecay method is suggested that increases sensitivity of the technique by up to 59%. Applications at rural study sites found some removal of FWCs in percolation areas of DWWTSs but they were still detectable 40 cm below the infiltration depth. FWCs were also detected as distinguishable peaks in impacted streams where septic tank effluents have a high contribution to the river flow. Copyright © 2017 Elsevier Ltd. All rights reserved.
BODIPY-based fluorometric sensor array for the highly sensitive identification of heavy-metal ions.
Niu, Li-Ya; Li, Hui; Feng, Liang; Guan, Ying-Shi; Chen, Yu-Zhe; Duan, Chun-Feng; Wu, Li-Zhu; Guan, Ya-Feng; Tung, Chen-Ho; Yang, Qing-Zheng
2013-05-02
A BODIPY(4,4-difluoro-4-bora-3a,4a-diaza-s-indacene)-based fluorometric sensor array has been developed for the highly sensitive detection of eight heavy-metal ions at micromolar concentration. The di-2-picolyamine (DPA) derivatives combine high affinities for a variety of heavy-metal ions with the capacity to perturb the fluorescence properties of BODIPY, making them perfectly suitable for the design of fluorometric sensor arrays for heavy-metal ions. 12 cross-reactive BODIPY fluorescent indicators provide facile identification of the heavy-metal ions using a standard chemometric approach (hierarchical clustering analysis); no misclassifications were found over 45 trials. Clear differentiation among heavy-metal ions as a function of concentration was also achieved, even down to 10(-7)M. A semi-quantitative interpolation of the heavy-metal concentration is obtained by comparing the total Euclidean distance of the measurement with a set of known concentrations in the library. Copyright © 2013 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Xu, Yang; Chen, Xi; Chai, Ran; Xing, Chengfen; Li, Huanrong; Yin, Xue-Bo
2016-07-01
A novel magnetic/fluorometric bimodal sensor was built from carbon dots (CDs) and MnO2. The resulting sensor was sensitive to glutathione (GSH), leading to apparent enhancement of magnetic resonance (MR) and fluorescence signals along with visual changes. The bimodal detection strategy is based on the decomposition of the CDs-MnO2 through a redox reaction between GSH and MnO2. This process causes the transformation from non-MR-active MnO2 to MR-active Mn2+, and is accompanied by fluorescence restoration of CDs. Compared with a range of other CDs, the polyethylenimine (PEI) passivated CDs (denoted as pCDs) were suitable for detection due to their positive surface potential. Cross-validation between MR and fluorescence provided detailed information regarding the MnO2 reduction process, and revealed the three distinct stages of the redox process. Thus, the design of a CD-based sensor for the magnetic/fluorometric bimodal detection of GSH was emphasized for the first time. This platform showed a detection limit of 0.6 μM with a linear range of 1-200 μM in the fluorescence mode, while the MR mode exhibited a linear range of 5-200 μM and a GSH detection limit of 2.8 μM with a visible change being observed rapidly at 1 μM in the MR images. Furthermore, the introduction of the MR mode allowed the biothiols to be easily identified. The integration of CD fluorescence with an MR response was demonstrated to be promising for providing detailed information and discriminating power, and therefore extend the application of CDs in sensing and imaging.A novel magnetic/fluorometric bimodal sensor was built from carbon dots (CDs) and MnO2. The resulting sensor was sensitive to glutathione (GSH), leading to apparent enhancement of magnetic resonance (MR) and fluorescence signals along with visual changes. The bimodal detection strategy is based on the decomposition of the CDs-MnO2 through a redox reaction between GSH and MnO2. This process causes the transformation from non-MR-active MnO2 to MR-active Mn2+, and is accompanied by fluorescence restoration of CDs. Compared with a range of other CDs, the polyethylenimine (PEI) passivated CDs (denoted as pCDs) were suitable for detection due to their positive surface potential. Cross-validation between MR and fluorescence provided detailed information regarding the MnO2 reduction process, and revealed the three distinct stages of the redox process. Thus, the design of a CD-based sensor for the magnetic/fluorometric bimodal detection of GSH was emphasized for the first time. This platform showed a detection limit of 0.6 μM with a linear range of 1-200 μM in the fluorescence mode, while the MR mode exhibited a linear range of 5-200 μM and a GSH detection limit of 2.8 μM with a visible change being observed rapidly at 1 μM in the MR images. Furthermore, the introduction of the MR mode allowed the biothiols to be easily identified. The integration of CD fluorescence with an MR response was demonstrated to be promising for providing detailed information and discriminating power, and therefore extend the application of CDs in sensing and imaging. Electronic supplementary information (ESI) available. See DOI: 10.1039/c6nr03129c
Fluorometric method for the determination of gas-phase hydrogen peroxide
NASA Technical Reports Server (NTRS)
Kok, Gregory L.; Lazrus, Allan L.
1986-01-01
The fluorometric gas-phase hydrogen peroxide procedure is based on the technique used by Lazrus et. al. for the determination of H2O2 in the liquid phase. The analytical method utilizes the reaction of H2O2 with horseradish peroxidase and p-hydroxphenylacetic acid (POPHA) to form the fluorescent dimer of POPHA. The analytical reaction responds stoichiometrically to both H2O2 and some organic hydroperoxides. To discriminate H2O2 from organic hydroperoxides, catalase is used to preferentially destroy H2O2. Using a dual-channel flow system the H2O2 concentration is determined by difference.
Xu, Xiu-Xiu; Qian, Ying
2017-08-05
An aldoxime containing fluorescent probe based on vinylpydine-appended triphenylamine-BODIPY has been designed and used for hypochlorite detection. OX-PPA-BODIPY was developed by introducing an aldoxime group into the 2-position of BODIPY, which can be used for the detection of hypochlorite with a sharp color change from pink to green. The attachment of 4-vinylpyridine moiety to triphenylamine-BODIPY constructs a fluorogen with desirable conjugated system. The probe, which displays extremely weak fluorescence owing to the CN isomerization mechanism at 2-position of BODIPY, responds to HClO/ClO - through a dramatic enhancement of its fluorescence intensity. This new probe, a naked-eye visible and fluorometric chemodosimeter, exhibits high selectivity and sensitivity toward hypochlorite over other reactive oxygen species (ROS) and anions. The detection is accompanied by a 20-fold increase in fluorescent intensity (Φ F from 0.02 to 0.43). The detection limit of the probe for hypochlorite is 7.37×10 -7 M. Moreover, OX-PPA-BODIPY can be used to detect hypochlorite in real water samples. Copyright © 2017 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Xu, Xiu-xiu; Qian, Ying
2017-08-01
An aldoxime containing fluorescent probe based on vinylpydine-appended triphenylamine-BODIPY has been designed and used for hypochlorite detection. OX-PPA-BODIPY was developed by introducing an aldoxime group into the 2-position of BODIPY, which can be used for the detection of hypochlorite with a sharp color change from pink to green. The attachment of 4-vinylpyridine moiety to triphenylamine-BODIPY constructs a fluorogen with desirable conjugated system. The probe, which displays extremely weak fluorescence owing to the Cdbnd N isomerization mechanism at 2-position of BODIPY, responds to HClO/ClO- through a dramatic enhancement of its fluorescence intensity. This new probe, a naked-eye visible and fluorometric chemodosimeter, exhibits high selectivity and sensitivity toward hypochlorite over other reactive oxygen species (ROS) and anions. The detection is accompanied by a 20-fold increase in fluorescent intensity (ΦF from 0.02 to 0.43). The detection limit of the probe for hypochlorite is 7.37 × 10- 7 M. Moreover, OX-PPA-BODIPY can be used to detect hypochlorite in real water samples.
Recommendations for fluorescence instrument qualification: the new ASTM Standard Guide.
DeRose, Paul C; Resch-Genger, Ute
2010-03-01
Aimed at improving quality assurance and quantitation for modern fluorescence techniques, ASTM International (ASTM) is about to release a Standard Guide for Fluorescence, reviewed here. The guide's main focus is on steady state fluorometry, for which available standards and instrument characterization procedures are discussed along with their purpose, suitability, and general instructions for use. These include the most relevant instrument properties needing qualification, such as linearity and spectral responsivity of the detection system, spectral irradiance reaching the sample, wavelength accuracy, sensitivity or limit of detection for an analyte, and day-to-day performance verification. With proper consideration of method-inherent requirements and limitations, many of these procedures and standards can be adapted to other fluorescence techniques. In addition, procedures for the determination of other relevant fluorometric quantities including fluorescence quantum yields and fluorescence lifetimes are briefly introduced. The guide is a clear and concise reference geared for users of fluorescence instrumentation at all levels of experience and is intended to aid in the ongoing standardization of fluorescence measurements.
NASA Technical Reports Server (NTRS)
Goyal, S. S.; Rains, D. W.; Huffaker, R. C.
1988-01-01
A fast, sensitive, simple, and highly reproducible method for routine assay of ammonium ion (NH4+) was developed by using HPLC equipment. The method is based on the reaction of NH4+ with o-phthalaldehyde (OPA) in the presence of 2-mercaptoethanol. After an on-line derivatization, the resulting NH4(+)-OPA product was quantified by using fluorometric or spectrophotometric detection. For fluorometric detection, the excitation and emission wavelengths were 410 and 470 nm, respectively. The spectrophotometric detection was made by measuring absorbance at 410 nm. Results on the effects of OPA-reagent composition and pH, reaction temperature, sample matrix, and linearity of the assay are presented. Even though it took about 2 min from the time of sample injection to the appearance of sample peak, sample injections could be overlapped at an interval of about 1 min. Thus, the actual time needed for analysis was about 1 min per assay. The method can be used in a fully automated mode by using an autosampler injector.
NASA Astrophysics Data System (ADS)
Su, Rongguo; Chen, Xiaona; Wu, Zhenzhen; Yao, Peng; Shi, Xiaoyong
2015-07-01
The feasibility of using fluorescence excitation-emission matrix (EEM) along with parallel factor analysis (PARAFAC) and nonnegative least squares (NNLS) method for the differentiation of phytoplankton taxonomic groups was investigated. Forty-one phytoplankton species belonging to 28 genera of five divisions were studied. First, the PARAFAC model was applied to EEMs, and 15 fluorescence components were generated. Second, 15 fluorescence components were found to have a strong discriminating capability based on Bayesian discriminant analysis (BDA). Third, all spectra of the fluorescence component compositions for the 41 phytoplankton species were spectrographically sorted into 61 reference spectra using hierarchical cluster analysis (HCA), and then, the reference spectra were used to establish a database. Finally, the phytoplankton taxonomic groups was differentiated by the reference spectra database using the NNLS method. The five phytoplankton groups were differentiated with the correct discrimination ratios (CDRs) of 100% for single-species samples at the division level. The CDRs for the mixtures were above 91% for the dominant phytoplankton species and above 73% for the subdominant phytoplankton species. Sixteen of the 85 field samples collected from the Changjiang River estuary were analyzed by both HPLC-CHEMTAX and the fluorometric technique developed. The results of both methods reveal that Bacillariophyta was the dominant algal group in these 16 samples and that the subdominant algal groups comprised Dinophyta, Chlorophyta and Cryptophyta. The differentiation results by the fluorometric technique were in good agreement with those from HPLC-CHEMTAX. The results indicate that the fluorometric technique could differentiate algal taxonomic groups accurately at the division level.
Tanaka, T; Nishihara, M; Seki, M; Sakamoto, A; Tanaka, K; Irifune, K; Morikawa, H
1995-05-01
Gold particles coated with beta-glucuronidase (GUS) mRNA with a 5' cap structure that had been synthesized in vitro were introduced, by use of a pneumatic particle gun, into pollen grains of lily (Lilium longiflorum), freesia (Freesia refracta) and tulip (Tulipa gesneriana). A fluorometric assay for the GUS activity indicated that in vitro synthesized GUS mRNA introduced into these pollen cells by particle bombardment was successfully expressed. GUS activity in extracts of the bombarded lily pollen became detectable fluorometrically within 30 min after bombardment, peaked at 6 h, then gradually decreased. This activity changed as a function of the developmental stage of the pollen cell of lily.
Structure–activity relationships for the binding of polymyxins with human α-1-acid glycoprotein
Azad, Mohammad A.K.; Huang, Johnny X.; Cooper, Matthew A.; Roberts, Kade D.; Thompson, Philip E.; Nation, Roger L.; Li, Jian; Velkov, Tony
2012-01-01
Here, for the first time, we have characterized binding properties of the polymyxin class of antibiotics for human α-1-acid glycoprotein (AGP) using a combination of biophysical techniques. The binding affinity of colistin, polymyxin B, polymyxin B3, colistin methansulfonate, and colistin nona-peptide was determined by isothermal titration calorimetry (ITC), surface plasma resonance (SPR) and fluorometric assay methods. All assay techniques indicated colistin, polymyxin B and polymyxin B3 display a moderate binding affinity for AGP. ITC and SPR showed there was no detectable binding affinity for colistin methansulfonate and colistin nona-peptide, suggesting both the positive charges of the diaminobutyric acid (Dab) side chains and the N-terminal fatty acyl chain of the polymyxin molecule are required to drive binding to AGP. In addition, the ITC and fluorometric data suggested that endogenous lipidic substances bound to AGP provide part of the polymyxin binding surface. A molecular model of the polymyxin B3–AGP F1*S complex was presented that illustrates the pivotal role of the N-terminal fatty acyl chain and the D-Phe6-L-Leu7 hydrophobic motif of polymyxin B3 for binding to the cleft-like ligand binding cavity of AGP F1*S variant. The model conforms with the entropy driven binding interaction characterized by ITC which suggests hydrophobic interactions coupled to desolvation events and conformational changes are the primary driving force for polymyxins binding to AGP. Collectively, the data are consistent with a role of this acute-phase reactant protein in the transport of polymyxins in plasma. PMID:22587817
Carbon Nanodots as Dual-Mode Nanosensors for Selective Detection of Hydrogen Peroxide
NASA Astrophysics Data System (ADS)
Shen, Cheng-Long; Su, Li-Xia; Zang, Jin-Hao; Li, Xin-Jian; Lou, Qing; Shan, Chong-Xin
2017-07-01
Hydrogen peroxide (H2O2) is an important product of oxidase-based enzymatic reactions, such as glucose/glucose oxidase (GOD) reaction. Therefore, the probing of generated H2O2 for achieving the detection of various carbohydrates and their oxidases is very significative. Herein, we report one kind of dual-emission carbon nanodots (CDs) that can serve as novel dual-mode nanosensors with both fluorometric and colorimetric output for the selective detection of H2O2. The dual-model nanosensors are established only by the undecorated dual-emission CDs, where significant fluorometric and colorimetric changes are observed with the addition of different concentrations of H2O2 in the CD solution, which benefit to the achievement of the naked-eye detection for H2O2. The mechanism of the nanosensors can be attributed to the fact that the external chemical stimuli like hydroxyl radicals from H2O2 bring about the change of surface properties and the aggregation of CDs, which dominate the emission and absorption of CDs. The constructed dual-mode nanosensors exhibit good biocompatibility and high selectivity toward H2O2 with a linear detection range spanning from 0.05 to 0.5 M and allow the detection of H2O2 as low as 14 mM.
Separation of attogram terpenes by the capillary zone electrophoresis with fluorometric detection.
Kubesová, Anna; Horká, Marie; Růžička, Filip; Slais, Karel; Glatz, Zdeněk
2010-11-12
An original method based on capillary zone electrophoresis with fluorimetric detection has been developed for the determination of terpenic compounds. The method is based on the separation of a terpenes dynamically labeled by the non-ionogenic tenside poly(ethylene glycol) pyrenebutanoate, which was used previously for the labeling of biopolymers. The background electrolytes were composed of taurine-Tris buffer (pH 8.4). In addition to the non-ionogenic tenside aceton and poly(ethylene glycol) were used as the additives. The capillary zone electrophoresis with fluorometric detection at the excitation wavelength 335 nm and the emission wavelength 463 nm was successfully applied to the analysis of tonalid, cholesterol, vitamin A, ergosterol, estrone and farnesol at level of 10(-17) mol L(-1). Farnesol, is produced by Candida albicans as an extracellular quorum-sensing molecule that influences expression of a number of virulence factors, especially morphogenesis and biofilm formation. It enables this yeast to cause serious nosocomial infections. The sensitivity of this method was demonstrated on the separation of farnesol directly from the cultivation medium. Copyright © 2010 Elsevier B.V. All rights reserved.
Horká, Marie; Růzicka, Filip; Holá, Veronika; Slais, Karel
2007-07-01
The optimized protocols of the bioanalytes separation, proteins and yeasts, dynamically modified by the nonionogenic tenside PEG pyrenebutanoate, were applied in CZE and CIEF with the acidic gradient in pH range 2-5.5, both with fluorescence detection. PEG pyrenebutanoate was used as a buffer additive for a dynamic modification of proteins and/or yeast samples. The narrow peaks of modified analytes were detected. The values of the pI's of the labeled proteins were calculated using new fluorescent pI markers in CIEF and they were found to be comparable with pI's of the native compounds. As an example of the possible use of the suggested CIEF technique, the mixed cultures of yeasts, Candida albicans, Candida glabrata, Candida kefyr, Candida krusei, Candida lusitaniae, Candida parapsilosis, Candida tropicalis, Candida zeylanoides, Geotrichum candidum, Saccharomyces cerevisiae, Trichosporon asahii and Yarrowia lipolytica, were reproducibly focused and separated with high sensitivity. Using UV excitation for the on-column fluorometric detection, the minimum detectable amounts of analytes, femtograms of proteins and down to ten cells injected on the separation capillary, were estimated.
Fluorometric enzymatic assay of L-arginine
NASA Astrophysics Data System (ADS)
Stasyuk, Nataliya; Gayda, Galina; Yepremyan, Hasmik; Stepien, Agnieszka; Gonchar, Mykhailo
2017-01-01
The enzymes of L-arginine (further - Arg) metabolism are promising tools for elaboration of selective methods for quantitative Arg analysis. In our study we propose an enzymatic method for Arg assay based on fluorometric monitoring of ammonia, a final product of Arg splitting by human liver arginase I (further - arginase), isolated from the recombinant yeast strain, and commercial urease. The selective analysis of ammonia (at 415 nm under excitation at 360 nm) is based on reaction with o-phthalaldehyde (OPA) in the presence of sulfite in alkali medium: these conditions permit to avoid the reaction of OPA with any amino acid. A linearity range of the fluorometric arginase-urease-OPA method is from 100 nM to 6 μМ with a limit of detection of 34 nM Arg. The method was used for the quantitative determination of Arg in the pooled sample of blood serum. The obtained results proved to be in a good correlation with the reference enzymatic method and literature data. The proposed arginase-urease-OPA method being sensitive, economical, selective and suitable for both routine and micro-volume formats, can be used in clinical diagnostics for the simultaneous determination of Arg as well as urea and ammonia in serum samples.
Yasuda, Makoto; Ota, Tatsuhiro; Morikawa, Atsushi; Mawatari, Ken-ichi; Fukuuchi, Tomoko; Yamaoka, Noriko; Kaneko, Kiyoko; Nakagomi, Kazuya
2013-09-01
A simple and rapid method for the simultaneous determination of serum nicotine and cotinine using high-performance liquid chromatography (HPLC)-fluorometric detection with a postcolumn ultraviolet-photoirradiation system was developed. Analytes were extracted from alkalinized human serum via liquid-liquid extraction using chloroform. The organic phase was back-extracted with the acidified aqueous phase, and the analytes were directly injected into an ion-pair reversed-phase HPLC system. 6-Aminoquinoline was used as an internal standard. Nicotine, cotinine, and 6-aminoquinoline were separated within 14min. The extraction efficiency of nicotine and cotinine was greater than 91%. The linear range was 0.30-1000ng for nicotine and 0.06-1000ng for cotinine. In serum samples from smokers, the concentrations of nicotine and cotinine were 8-15ng/mL and 156-372ng/mL, respectively. Copyright © 2013 Elsevier B.V. All rights reserved.
Koller, E; Wolfbeis, O S
1984-11-15
A direct and continuous kinetic method for the photometric and fluorometric determination of various acid phosphatases is described. It is based on new coumarin-derived phosphates, which after enzymatic hydrolysis undergo dissociation to form intensely colored and strongly fluorescent phenolate anions. The latter have absorption maxima ranging from 385 to 505 nm, and fluorescence maxima between 470 and 595 nm. The new substrates were compared with respect to their rate of enzymatic hydrolysis, optimum pH, and detection limits of acid phosphatase from potato and wheat germ. Detection limits of 0.001 unit/ml were found by photometry, and as low as 0.00006 unit/ml by fluorometry. The principal advantages of the new substrates over existing ones are longwave absorptions and emissions, large Stokes shifts, and the low pKa values of the corresponding phenols, thus allowing a direct and continuous assay of acid phosphatase even in weakly acidic solutions.
Use of a Fluorometric Imaging Plate Reader in high-throughput screening
NASA Astrophysics Data System (ADS)
Groebe, Duncan R.; Gopalakrishnan, Sujatha; Hahn, Holly; Warrior, Usha; Traphagen, Linda; Burns, David J.
1999-04-01
High-throughput screening (HTS) efforts at Abbott Laboratories have been greatly facilitated by the use of a Fluorometric Imaging Plate Reader. The FLIPR consists of an incubated cabinet with integrated 96-channel pipettor and fluorometer. An argon laser is used to excite fluorophores in a 96-well microtiter plate and the emitted fluorometer. An argon laser is used to excite fluorophores in a 96-well microtiter plate and the emitted fluorescence is imaged by a cooled CCD camera. The image data is downloaded from the camera and processed to average the signal form each well of the microtiter pate for each time point. The data is presented in real time on the computer screen, facilitating interpretation and trouble-shooting. In addition to fluorescence, the camera can also detect luminescence form firefly luciferase.
NASA Astrophysics Data System (ADS)
Zhu, Qin; Li, Zhao; Mu, Lan; Zeng, Xi; Redshaw, Carl; Wei, Gang
2018-01-01
The compound (E)-8-hydroxyl-2-[(E)-2-(2, 4-dihydroxyphenyl)vinyl]-quinoline (1) has been developed as a fluorometric and colorimetric dual-modal probe for pH detection in solution and in vivo. Remarkable changes in the fluorescence intensity with large Stokes shifts and colorimetric responses were observed as a function of pH. The sensing mechanisms involving protonation and deprotonation processes over the acidic and alkaline pH ranges were confirmed by 1H NMR and IR spectroscopic analysis. Furthermore, the application of probe 1 for the imaging of live PC3 cells was successfully achieved. Test strips based on probe 1 were fabricated, and were found to act as a convenient and efficient pH test kits.
Mondal, Sanjoy; Bairi, Partha; Das, Sujoy; Nandi, Arun K
2018-04-11
Detection of nitroaromatics at ultralow concentration is a major security concern in defense, forensics, and environmental science. To this end, a new triarylamine-cored dendritic gelator (OGR) was synthesized, which produced thermoreversible, thixotropic, and fluorescent gels in n-octanol. On gelation, both π-π* transitions and the emission peak of the gelator show redshifts with a 4.5-fold increase of fluorescence intensity in the gel state indicating J-aggregation. The nitrogen lone-pair electrons of OGR make it a donor, and electron transfer occurs to acceptor nitroaromatics causing fluorescence quenching, which is further promoted due to its acidity. The Stern-Volmer rate constants measured for different nitroaromatics showed that it senses picric acid (PA) best. The contact-mode technique with OGR-treated paper strips can allow naked-eye detection of PA under UV light down to 10 -11 m concentration within 30 s. Reusability of the gel is achieved by treating OGR@PA x with NaOH solution. Impedance spectroscopic results indicated a decrease of both charge-transport resistance and Warburg impedance on successive addition of PA. The limits of detection of PA determined from fluorescence and impedance measurements match well. Thus, the OGR gel is a reusable, low-cost, specific sensor for PA by naked-eye colorimetric, fluorescence, and impedance techniques. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.
Jiang, Lina; Wu, Jing; Wang, Guilan; Ye, Zhiqiang; Zhang, Wenzhu; Jin, Dayong; Yuan, Jingli; Piper, James
2010-03-15
The time-resolved luminescence bioassay technique using luminescent lanthanide complexes as labels is a highly sensitive and widely used bioassay method for clinical diagnostics and biotechnology. A major drawback of the current technique is that the luminescent lanthanide labels require UV excitation (typically less than 360 nm), which can damage living biological systems and is holding back further development of time-resolved luminescence instruments. Herein we describe two approaches for preparing a visible-light-sensitized Eu(3+) complex in aqueous media for time-resolved fluorometric applications: a dissociation enhancement aqueous solution that can be excited by visible light for ethylenediaminetetraacetate (EDTA)-Eu(3+) detection and a visible-light-sensitized water-soluble Eu(3+) complex conjugated bovine serum albumin (BSA) for biolabeling and time-resolved luminescence bioimaging. In the first approach, a weakly acidic aqueous solution consisting of 4,4'-bis(1'',1'',1'',2'',2'',3'',3''-heptafluoro-4'',6''-hexanedion-6''-yl)-o-terphenyl (BHHT), 2-(N,N-diethylanilin-4-yl)-4,6-bis(3,5-dimethylpyrazol-1-yl)-1,3,5-triazine (DPBT), and Triton X-100 was prepared. This solution shows a strong luminescence enhancement effect for EDTA-Eu(3+) with a wide excitation wavelength range from UV to visible light (a maximum at 387 nm) and a long luminescence lifetime (520 micros), to provide a novel dissociation enhancement solution for time-resolved luminescence detection of EDTA-Eu(3+). In the second approach, a ternary Eu(3+) complex, 4,4'-bis(1'',1'',1'',2'',2'',3'',3''-heptafluoro-4'',6''-hexanedion-6''-yl)-chlorosulfo-o-terphenyl (BHHCT)-Eu(3+)-DPBT, was covalently bound to BSA to form a water-soluble BSA-BHHCT-Eu(3+)-DPBT conjugate. This biocompatible conjugate is of the visible-light excitable feature in aqueous media with a wide excitation wavelength range from UV to visible light (a maximum at 387 nm), a long luminescence lifetime (460 micros), and a higher quantum yield (27%). The conjugate was successfully used for streptavidin (SA) labeling and time-resolved luminescence imaging detection of three environmental pathogens, Giardia lamblia , Cryptosporidium muris , and Cryptosporidium parvum , in water samples. Our strategy gives a general idea for designing a visible-light-sensitized Eu(3+) complex for time-resolved luminescence bioassay applications.
Bose, Debosreeta; Sarkar, Deboleena; Chattopadhyay, Nitin
2010-01-01
In the present investigation, an attempt has been made to study the interaction of phenosafranin (PSF), a cationic phenazinium dye with the transport proteins, bovine serum albumin (BSA) and human serum albumin (HSA), employing steady-state and time-resolved fluorometric and circular dichroism (CD) techniques. The photophysical properties of the dye are altered on binding with the serum proteins. An explicit study with respect to the modification of the fluorescence and fluorescence anisotropy upon binding, effect of denaturant, fluorescence lifetime and CD measurements reveal that the dye binds to both BSA and HSA with almost the same affinity. Far-UV CD spectra indicate a decrease in the percentage of alpha-helicity only for BSA upon binding with the probe. Near-UV CD responses indicate an alteration in the tertiary structure of both the transport proteins because of binding.
Wang, Yanying; Yang, Yan; Liu, Wei; Ding, Fang; Zhao, Qingbiao; Zou, Ping; Wang, Xianxiang; Rao, Hanbing
2018-05-04
A dual-read detection system is described for non-enzymatic and non-aggregation based analysis of uric acid (UA). Silver triangular nanoprisms (AgTNPs) were used as colorimetric probes, while the reduction in the fluorescence of nitrogen-doped carbon quantum dots (N-CQDs) served as the fluorometric readout. The absorption band of the AgTNPs overlaps the emission band of N-CQDs (with a peak at 440 nm). Therefore, fluorescence is reduced owing to an inner filter effect. The AgTNPs are etched if exposed to H 2 O 2 , and round nanodiscs are formed. In the presence of UA, etching of the AgTNPs is suppressed because the facets of the AgTNPs are coated with UA. The absorbance, best measured at 683 nm, increases with the concentration of the pre-added UA. The colorimetric assay works in the 0.1-45 μM UA concentration range, and the fluorometric assay between 1 and 42 μM of UA. The respective detection limits are 50 and 200 nM, respectively. The probe can be used for direct visualization of UA. The method was successfully applied to the determination of UA in urine samples. Graphical abstract The fluorescence of nitrogen-doped carbon quantum dots (N-CQDs) is quenched by AgTNPs (silver triangular nanoprisms). As the AgTNPs are etched by H 2 O 2 , fluorescence recovers in the system after H 2 O 2 is added, and also undergoes a color change. Uric acid (UA) protects the AgTNPs from etching because the facets of the AgTNPs are coated with UA. The fluorescence of N-CQDs decreases. Thus, a dual-read probe is developed for determination of UA.
NASA Astrophysics Data System (ADS)
Rana, Md. Muhit
DNA nanotechnology has shown great promise in molecular diagnostic, bioanalytical and biomedical applications. The great challenge of detecting target analytes, biomarkers and small molecules, in molecular diagnostics is low yield sensitivity. To address this challenge, different nanomaterials have been used for a long time and to date there is no such cost-effective bioanalytical technique which can detect these target biomarkers (DNA, RNA, circulating DNA/miRNA) or environmental heavy metal ions (Hg2+ and Ag+) in a cost-effective and efficient manner. Herein, we initially discuss two possible bioanalytical detection methods- a) colorimetric and b) fluorometric assays which are very popular nowadays due to their distinctive spectroscopic properties. Finally, we report the promising colorimetric assay using a novel DNA based amplification strategy know as hybridization chain reaction (HCR) for potential application in the visual detection of low copies of biomarkers (miRNAs as little as 20 femtomole in an RNA pool and cell extracts in seven different combinations and Ebola virus DNA as low as 400 attomoles in liquid biopsy mimics in sixteen different combinations), environmental and biological heavy metal ions (mercury and silver concentrations as low as 10 pM in water, soil and urine samples) and also successfully applied to a molecular logic gate operation to distinguish OR and AND logic gates. No results showed any false-positive or false-negative information. On the other hand, we also discuss the future possibilities of HCR amplification technology, which is very promising for fluorometric bioanalysis. The HCR based nanoprobe technology has numerous remarkable advantages over other methods. It is re-programmable, simple, inexpensive, easy to assemble and operate and can be performed with visual and spectroscopic read-outs upon recognition of the target analytes. This rapid, specific and sensitive approach for biomarkers and heavy metal ion detection generates an on-site signal while eliminating the use of sophisticated high-maintenance instrumentation. We demonstrate that this state-of-the-art technology and methodology can potentially serve as an alternative approach to detect novel disease biomarkers, small molecules and inorganic compounds. This approach can be combined with the current existing methods for real-time point-of-care molecular diagnostics and is significant for preclinical or clinical studies.
Berenguer, J A; Gonzalez, L; Jimenez, I; Legarda, T M; Olmedo, J B; Burdaspal, P A
1993-01-01
A study was undertaken to determine if any reduction in contamination of Acanthocardia tuberculatum L. (Mediterranean cockle) by paralytic shellfish poisons (PSP) could be enhanced by operations carried out during the industrial canning process, allowing contaminated raw material to be commercially marketed in safe conditions for edible purposes. A general decrease in PSP levels was consistently observed when comparing raw materials and their corresponding final products, these dropping to acceptable levels. PSP levels were determined by mouse bioassay and a fluorometric method, and saxitoxin was determined by HPLC. The detoxifying effects averaged over 71.7% and 81.8% (mouse bioassay), 70.6% and 90.9% (fluorometric method), 77.9% and 83.5% (HPLC), for boiling and sterilizing operations respectively. The highest level detected in raw material was 800 micrograms/100 g by mouse bioassay.
Scholz, Norman; Behnke, Thomas; Resch-Genger, Ute
2018-01-01
Micelles are of increasing importance as versatile carriers for hydrophobic substances and nanoprobes for a wide range of pharmaceutical, diagnostic, medical, and therapeutic applications. A key parameter indicating the formation and stability of micelles is the critical micelle concentration (CMC). In this respect, we determined the CMC of common anionic, cationic, and non-ionic surfactants fluorometrically using different fluorescent probes and fluorescence parameters for signal detection and compared the results with conductometric and surface tension measurements. Based upon these results, requirements, advantages, and pitfalls of each method are discussed. Our study underlines the versatility of fluorometric methods that do not impose specific requirements on surfactants and are especially suited for the quantification of very low CMC values. Conductivity and surface tension measurements yield smaller uncertainties particularly for high CMC values, yet are more time- and substance consuming and not suitable for every surfactant.
Evaluation of kinetic phosphorescence analysis for the determination of uranium
DOE Office of Scientific and Technical Information (OSTI.GOV)
Croatto, P.V.; Frank, I.W.; Johnson, K.D.
In the past, New Brunswick Laboratory (NBL) has used a fluorometric method for the determination of sub-microgram quantities of uranium. In its continuing effort to upgrade and improve measurement technology, NBL has evaluated the commercially-available KPA-11 kinetic phosphorescence analyzer (Chemchek, Richland, WA). The Chemchek KPA-11 is a bench-top instrument which performs single-measurement, quench-corrected analyses for trace uranium. It incorporates patented kinetic phosphorimetry techniques to measure and analyze sample phosphorescence as a function of time. With laser excitation and time-corrected photon counting, the KPA-11 has a lower detection limit than conventional fluorometric methods. Operated with a personal computer, the state-of-the-art KPA-11more » offers extensive time resolution and phosphorescence lifetime capabilities for additional specificity. Interferences are thereby avoided while obtaining precise measurements. Routine analyses can be easily and effectively accomplished, with the accuracy and precision equivalent to the pulsed-laser fluorometric method presently performed at NBL, without the need for internal standards. Applications of kinetic phosphorimetry at NBL include the measurement of trace level uranium in retention tank, waste samples, and low-level samples. It has also been used to support other experimental activities at NBL by the measuring of nanogram amounts of uranium contamination (in blanks) in isotopic sample preparations, and the determining of elution curves of different ion exchange resins used for uranium purification. In many cases, no pretreatment of samples was necessary except to fume them with nitric acid, and then to redissolve and dilute them to an appropriate concentration with 1 M HNO{sub 3} before measurement. Concentrations were determined on a mass basis ({micro}g U/g of solution), but no density corrections were needed since all the samples (including the samples used for calibration) were in the same density matrix (1 M HNO{sub 3}). A statistical evaluation of the determination of uranium using kinetic phosphorimetry is described in this report, along with a discussion of the method, and an evaluation of the use of plastic versus quartz cuvettes. Measurement with a precision of {+-} 3--4% relative standard deviation (RSD) and an accuracy of better than {+-} 2% relative difference (RD) are obtained in the 0.0006 to 5 {micro}g U/g-solution range. The instrument detection limit is 0.04 ppb (4 x 10{sup {minus}5} {micro}g U/g solution) using quartz cells, and 0.11 ppb (11 x 10{sup {minus}5} {micro}g U/g solution) using disposable methacrylate cuvettes.« less
Hu, Teh-Min; Chiu, Shih-Jiuan; Hsu, Yu-Ming
2014-08-22
Simultaneous production of nitric oxide (NO) and superoxide generates peroxynitrite and causes nitroxidative stress. The fluorometric method for NO detection is based on the formation of a fluorescent product from the reaction of a nonfluorescent probe molecule with NO-derived nitrosating species. Here, we present an example of how nitroxidative chemistry could interact with fluorescent probe chemistry. 2,3-Naphthotriazole (NAT) is the NO-derived fluorescent product of 2,3-diaminonaphthalene (DAN), a commonly used NO-detecting molecule. We show that NO/superoxide cogeneration, and particularly peroxynitrite, mediates the chemical decomposition of NAT. Moreover, the extent of NAT decomposition depends on the relative fluxes of NO and superoxide; the maximum effect being reached at almost equivalent generation rates for both radicals. The rate constant for the reaction of NAT with peroxynitrite was determined to be 2.2×10(3)M(-1)s(-1). Further, various peroxynitrite scavengers were shown to effectively inhibit NO/superoxide- and peroxynitrite-mediated decomposition of NAT. Taken together, the present study suggests that the interference of a fluorometric NO assay can be originated from the interaction between the final fluorescent product and the formed reactive nitrogen and oxygen species. Copyright © 2014 Elsevier Inc. All rights reserved.
Harazono, Akira; Kobayashi, Tetsu; Kawasaki, Nana; Itoh, Satsuki; Tada, Minoru; Hashii, Noritaka; Ishii, Akiko; Arato, Teruyo; Yanagihara, Shigehiro; Yagi, Yuki; Koga, Akiko; Tsuda, Yuriko; Kimura, Mikiko; Sakita, Masashi; Kitamura, Satoshi; Yamaguchi, Hideto; Mimura, Hisashi; Murata, Yoshimi; Hamazume, Yasuki; Sato, Takayuki; Natsuka, Shunji; Kakehi, Kazuaki; Kinoshita, Mitsuhiro; Watanabe, Sakie; Yamaguchi, Teruhide
2011-05-01
The various monosaccharide composition analysis methods were evaluated as monosaccharide test for glycoprotein-based pharmaceuticals. Neutral and amino sugars were released by hydrolysis with 4-7N trifluoroacetic acid. The monosaccharides were N-acetylated if necessary, and analyzed by high-performance liquid chromatography (HPLC) with fluorometric or UV detection after derivatization with 2-aminopyridine, ethyl 4-aminobenzoate, 2-aminobenzoic acid or 1-phenyl-3-methyl-5-pyrazolone, or high pH anion exchange chromatography with pulsed amperometric detection (HPAEC-PAD). Sialic acids were released by mild acid hydrolysis or sialidase digestion, and analyzed by HPLC with fluorometric detection after derivatization with 1,2-diamino-4,5-methylenedioxybenzene, or HPAEC-PAD. These methods were verified for resolution, linearity, repeatability, and accuracy using a monosaccharide standard solution, a mixture of epoetin alfa and beta, and alteplase as models. It was confirmed that those methods were useful for ensuring the consistency of glycosylation. It is considered essential that the analytical conditions including desalting, selection of internal standards, release of monosaccharides, and gradient time course should be determined carefully to eliminate interference of sample matrix. Various HPLC-based monosaccharide analysis methods were evaluated as a carbohydrate test for glycoprotein pharmaceuticals by an inter-laboratory study. Copyright © 2011 The International Association for Biologicals. Published by Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Leskinen, Stephaney D.; Schlemmer, Sarah M.; Kearns, Elizabeth A.; Lim, Daniel V.
2009-02-01
The development of rapid assays for detection of microbial pathogens in complex matrices is needed to protect public health due to continued outbreaks of disease from contaminated foods and water. An Escherichia coli O157:H7 detection assay was designed using a robotic, fluorometric assay system. The system integrates optics, fluidics, robotics and software for the detection of foodborne pathogens or toxins in as many as four samples simultaneously. It utilizes disposable fiber optic waveguides coated with biotinylated antibodies for capture of target analytes from complex sample matrices. Computer-controlled rotation of sample cups allows complete contact between the sample and the waveguide. Detection occurs via binding of a fluorophore-labeled antibody to the captured target, which leads to an increase in the fluorescence signal. Assays are completed within twenty-five minutes. Sample matrices included buffer, retentate (material recovered from the filter of the Automated Concentration System (ACS) following hollow fiber ultrafiltration), spinach wash and ground beef. The matrices were spiked with E. coli O157:H7 (103-105 cells/ml) and the limits of detection were determined. The effect of sample rotation on assay sensitivity was also examined. Rotation parameters for each sample matrix included 10 ml with rotation, 5 ml with rotation and 0.1 ml without rotation. Detection occurred at 104 cells/ml in buffer and spinach wash and at 105 cells/ml in retentate and ground beef. Detection was greater for rotated samples in each matrix except ground beef. Enhanced detection of E. coli from large, rotated volumes of complex matrices was confirmed.
Novel application of digital microfluidics for the detection of biotinidase deficiency in newborns.
Graham, Carrie; Sista, Ramakrishna S; Kleinert, Jairus; Wu, Ning; Eckhardt, Allen; Bali, Deeksha; Millington, David S; Pamula, Vamsee K
2013-12-01
Newborn screening for biotinidase deficiency can be performed using a fluorometric enzyme assay on dried blood spot specimens. As a pre-requisite to the consolidation of different enzymatic assays onto a single platform, we describe here a novel analytical method for detecting biotinidase deficiency using the same digital microfluidic cartridge that has already been demonstrated to screen for five lysosomal storage diseases (Pompe, Fabry, Gaucher, Hurler and Hunter) in a multiplex format. A novel assay to quantify biotinidase concentration in dried blood spots (DBS) was developed and optimized on the digital microfluidic platform using proficiency testing samples from the Centers for Disease Control and Prevention. The enzymatic assay uses 4-methylumbelliferyl biotin as the fluorogenic substrate. Biotinidase deficiency assays were performed on normal (n=200) and deficient (n=7) newborn DBS specimens. Enzymatic activity analysis of biotinidase deficiency revealed distinct separation between normal and affected DBS specimens using digital microfluidics and these results matched the expected activity. This study has demonstrated performance of biotinidase deficiency assays by measurement of 4-methylumbelliferyl product on a digital microfluidic platform. Due to the inherent ease in multiplexing on such a platform, consolidation of other fluorometric assays onto a single cartridge may be realized. © 2013.
Yang, Dongqin; Luo, Minchuan; Di, Junwei; Tu, Yifeng; Yan, Jilin
2018-05-18
A method is described for ratiometric fluorometric assays of H 2 O 2 by using two probes that have distinct response profiles. Under the catalytic action of ferrous ion, the 615 nm emission of protein-stabilized gold nanoclusters (under 365 nm photoexcitation) is quenched by H 2 O 2 , while an increased signal is generated with a peak at 450 nm by oxidizing coumarin with the H 2 O 2 /Fe(II) system to form a blue emitting fluorophore. These decrease/increase responses give a ratiometric signal. The ratio of the fluorescences at the two peaks are linearly related to the concentration of H 2 O 2 in the range from 0.05 to 10 μM, with a 7.7 nM limit of detection. The detection scheme was further coupled to the urate oxidase catalyzed oxidation of uric acid which proceeds under the formation of H 2 O 2 . This method provides an simple and effective means for the construction of ratiometric fluorometric (enzymatic) assays that involve the detection of H 2 O 2 . Graphical abstract Under catalysis by ferrous ion, hydrogen peroxide quenches the luminescence of gold nanoclusters (AuNCs) and oxidizes coumarin into a fluorescent derivative, which rendered fluorescence ON and OFF at two distinct wavelengths for ratiometric measurements.
Ramirez-Sanchez, Israel; Maya, Lisandro; Ceballos, Guillermo; Villarreal, Francisco
2010-12-01
Polyphenolic compounds of the flavanoid family are abundantly present in cacao seed and its cocoa products. Results from studies using cocoa products indicate beneficial effects of flavanols on cardiovascular endpoints. Evidence indicates that (-)-epicatechin is the main cacao flavanol associated with cardiovascular effects, so the accurate quantification of its content in cacao seeds or cocoa products is important. Common methods for the quantification of phenolic content in cocoa products are based on the reaction of phenols with colorimetric reagents such as the Folin-Ciocalteu (FC) In this study, we compared the FC method of phenolic determinations using 2 different standards (gallic acid and (-)-epicatechin) to construct calibration curves. We compare these results with those obtained from a simple fluorometric method (Ex(280)/Em(320) nm) used to determine catechin/(-)-epicatechin content in samples of cacao seeds and cocoa products. Values obtained from the FC method determination of polyphenols yield an overestimation of phenol (flavonoid) content when gallic acid is used as standard. Moreover, the epicatechin is a more reliable standard because of its abundance in cacao seeds and cocoa products. The use of fluorometric spectra yields a simple and highly quantitative means for a more precise and rapid quantification of cacao catechins. Fluorometric values are essentially in agreement with those reported using more cumbersome methods. In conclusion, the use of fluorescence emission spectra is a quick, practical and suitable means to quantifying catechins in cacao seeds and cocoa products.
Fluorometric prediction of successful amputation level in the ischemic limb.
Silverman, D G; Rubin, S M; Reilly, C A; Brousseau, D A; Norton, K J; Wolf, G L
1985-01-01
The present study was undertaken to compare fluorometric documentation of fluorescein dye delivery with the standard means of determining the level at which an amputation should be performed in the dysvascular extremity. Thirty-nine patients underwent lower-extremity amputation at the level determined by the surgeon based upon physical examination, angiography, segmental pressure indices, and/or pulse volume recordings. In addition, fiberoptic fluorometry was performed preoperatively. After intravenous administration of sodium fluorescein (4-8 mg/kg), fluorometric readings were obtained by placing the fluorometer's light guide on 126 reading sites. Fluorometric findings were evaluated retrospectively, and therefore did not influence the surgeon's decision. Of the 39 amputations performed overall, only 26 healed. The accuracy of the standard criteria was lowest for the 20 below-ankle amputations, where only 12 cases healed. Alternatively, fluorometric indices separated healing from nonhealing sites in 36 of the 39 cases and in 18 of the 20 below-ankle amputations. Overall, healing sites averaged 94 percent of the fluorescence of the healthy reference area, while nonhealing sites averaged only 29 percent. We conclude that fluorometry should prove to be a valuable adjunct in the assessment of the dysvascular extremity. It uses a low dose of dye, is easy to perform, and is readily repeatable.
Fluorophore-based sensor for oxygen radicals in processing plasmas
DOE Office of Scientific and Technical Information (OSTI.GOV)
Choudhury, Faraz A.; Shohet, J. Leon, E-mail: shohet@engr.wisc.edu; Sabat, Grzegorz
2015-11-15
A high concentration of radicals is present in many processing plasmas, which affects the processing conditions and the properties of materials exposed to the plasma. Determining the types and concentrations of free radicals present in the plasma is critical in order to determine their effects on the materials being processed. Current methods for detecting free radicals in a plasma require multiple expensive and bulky instruments, complex setups, and often, modifications to the plasma reactor. This work presents a simple technique that detects reactive-oxygen radicals incident on a surface from a plasma. The measurements are made using a fluorophore dye thatmore » is commonly used in biological and cellular systems for assay labeling in liquids. Using fluorometric analysis, it was found that the fluorophore reacts with oxygen radicals incident from the plasma, which is indicated by degradation of its fluorescence. As plasma power was increased, the quenching of the fluorescence significantly increased. Both immobilized and nonimmobilized fluorophore dyes were used and the results indicate that both states function effectively under vacuum conditions. The reaction mechanism is very similar to that of the liquid dye.« less
Rhaman, Md Mhahabubur; Hasan, Mohammad H; Alamgir, Azmain; Xu, Lihua; Powell, Douglas R; Wong, Bryan M; Tandon, Ritesh; Hossain, Md Alamgir
2018-01-10
The selective detection of citrate anions is essential for various biological functions in living systems. A quantitative assessment of citrate is required for the diagnosis of various diseases in the human body; however, it is extremely challenging to develop efficient fluorescence and color-detecting molecular probes for sensing citrate in water. Herein, we report a macrocycle-based dinuclear foldamer (1) assembled with eosin Y (EY) that has been studied for anion binding by fluorescence and colorimetric techniques in water at neutral pH. Results from the fluorescence titrations reveal that the 1·EY ensemble strongly binds citrate anions, showing remarkable selectivity over a wide range of inorganic and carboxylate anions. The addition of citrate anions to the 1·EY adduct led to a large fluorescence enhancement, displaying a detectable color change under both visible and UV light in water up to 2 μmol. The biocompatibility of 1·EY as an intracellular carrier in a biological system was evaluated on primary human foreskin fibroblast (HF) cells, showing an excellent cell viability. The strong binding properties of the ensemble allow it to be used as a highly sensitive, detective probe for biologically relevant citrate anions in various applications.
NASA Technical Reports Server (NTRS)
Garland, Jay L.; Roberts, Michael S.; Levine, Lanfang H.; Mills, Aaron L.
2003-01-01
Community-level physiological profiling based upon fluorometric detection of oxygen consumption was performed on hydroponic rhizosphere and salt marsh litter samples by using substrate levels as low as 50 ppm with incubation times between 5 and 24 h. The rate and extent of response were increased in samples acclimated to specific substrates and were reduced by limiting nitrogen availability in the wells.
Optoacoustic detection of viral antigens using targeted gold nanorods
NASA Astrophysics Data System (ADS)
Maswadi, Saher; Woodward, Lee; Glickman, Randolph D.; Barsalou, Norman
2009-02-01
We are detecting antigens (Ag), isolated from infectious organisms, utilizing laser optoacoustic spectroscopy and antibody-coupled gold nanorod (NR) contrast agents specifically targeted to the antigen of interest. We have detected, in clinical ocular samples, both Herpes Simplex Virus Type 1 and 2 (HSV-1 and HSV-2) . A monoclonal antibody (Ab) specific to both HSV-1 and HSV-2 was conjugated to gold nanorods to produce a targeted contrast agent with a strong optoacoustic signal. Elutions obtained from patient corneal swabs were adsorbed in standard plastic micro-wells. An immunoaffinity reaction was then performed with the functionalized gold nanorods, and the results were probed with an OPO laser, emitting wavelengths at the peak absorptions of the nanorods. Positive optoacoustic responses were obtained from samples containing authentic (microbiologically confirmed) HSV-1 and HSV-2. To obtain an estimate of the sensitivity of the technique, serial dilutions from 1 mg/ml to 1 pg/ml of a C. trachomatis surface Ag were prepared, and were probed with a monoclonal Ab, specific to the C. trachomatis surface Ag, conjugated to gold nanorods. An optoacoustic response was obtained, proportional to the concentration of antigen, and with a limit of detection of about 5 pg/ml. The optoacoustic signals generated from micro-wells containing albumin or saline were similar to those from blank wells. The potential benefit of this method is identify viral agents more rapidly than with existing techniques. In addition, the sensitivity of the assay is comparable or superior to existing colorimetric- or fluorometric-linked immunoaffinity assays.
1984-04-01
applicability . 4. When natural tracers have been unavailable, artificial tracers have been introduced to mark the inflow. Radioactive tracers have proved to be...day. The USGS has set even stricter standards for its field applications , limiting concentrations near water intakes to 10 ppb (Wilson 1968). 20. In a...its use (e.g., preparing impact statements based on knowledge of nitrite concentrations in the application area or limiting concentra- tions near
Saberi, Zeinab; Rezaei, Behzad; Faroukhpour, Hossein; Ensafi, Ali Ashghar
2018-05-17
Cobalt oxyhydroxide (CoOOH) nanosheets are efficient fluorescence quenchers due to their specific optical properties and high surface area. The combination of CoOOH nanosheets and carbon dots (CDs) has not been used in any aptasensor based on fluorescence quenching so far. An aptamer based fluorometric assay is introduced that is making use of fluorescent CDs conjugated to the aptamer against methamphetamine (MTA), and of CoOOH nanosheets which reduce the fluorescence of the CDs as a quencher. The results revealed that the conjugated CDs with aptamers were able to enclose the CoOOH nanosheets. Consequently, fluorescence is quenched. If the aptamer on the CD binds MTA, the CDs are detached from CoOOH nanosheets. As a result, fluorescence is restored proportionally to zhe MTA concentration. The fluorometric limit of detection is 1 nM with a dynamic range from 5 to 156 nM. The method was validated by comparing the results obtained by the new method to those obtained by ion mobility spectroscopy. Theoretical studies showed that the distance between CoOOH nanosheet and C-Ds is approximately 7.6 Å which can illustrate the possibility of FRET phenomenon. The interactions of MTA and the aptamer were investigated using molecular dynamic simulation (MDS). Graphical abstract Carbon dots (C-Ds) were prepared from grape leaves, conjugated to aptamer, and adsorbed on CoOOH nanosheets. So, the fluorescence of C-Ds is quenched. On addition of MTA, fluorescence is restored.
Biardi, J E; Nguyen, K T; Lander, S; Whitley, M; Nambiar, K P
2011-02-01
Metalloproteases are responsible for the hemorrhagic effects of many snake venoms and contribute to other pathways that lead to local tissue damage. Methods that quantify snake venom metalloproteases (SVMP) are therefore valuable tools in research on the clinical, physiological, and biochemical effects of envenomation. Comparative analysis of individual, population, and species differences requires screening of large numbers of samples and treatments, and therefore require a method of quantifying SVMP activity that is simple, rapid, and sensitive. This paper demonstrates the properties of a new fluorometric assay of SVMP activity that can provide a measure of metalloprotease activity in 1 h. The assay is reliable, with variation among replicates sufficiently small to reliably detect differences in between species (F(19,60) = 2924, p < 0.001), even for those venoms with low overall activity. It is also sensitive enough to detect differences among venoms using <2 ng of whole venom protein. We provide an example use of this assay to detect the presence of natural SVMP inhibitors in minute samples of blood plasma from rock squirrels (S. variegatus), a natural prey species for North American rattlesnakes. We propose this assay is a useful addition to the set of tools used to characterize venoms, as well as high-throughput screening of natural or synthetic inhibitors, or other novel therapeutic agents against SVMP effects. Copyright © 2010 Elsevier Ltd. All rights reserved.
Botasini, Santiago; Heijo, Gonzalo; Méndez, Eduardo
2013-10-24
In recent years, it has increased the number of works focused on the development of novel nanoparticle-based sensors for mercury detection, mainly motivated by the need of low cost portable devices capable of giving fast and reliable analytical response, thus contributing to the analytical decentralization. Methodologies employing colorimetric, fluorometric, magnetic, and electrochemical output signals allowed reaching detection limits within the pM and nM ranges. Most of these developments proved their suitability in detecting and quantifying mercury (II) ions in synthetic solutions or spiked water samples. However, the state of art in these technologies is still behind the standard methods of mercury quantification, such as cold vapor atomic absorption spectrometry and inductively coupled plasma techniques, in terms of reliability and sensitivity. This is mainly because the response of nanoparticle-based sensors is highly affected by the sample matrix. The developed analytical nanosystems may fail in real samples because of the negative incidence of the ionic strength and the presence of exchangeable ligands. The aim of this review is to critically consider the recently published innovations in this area, and highlight the needs to include more realistic assays in future research in order to make these advances suitable for on-site analysis. Copyright © 2013 Elsevier B.V. All rights reserved.
Jiménez-López, J; Llorent-Martínez, E J; Ortega-Barrales, P; Ruiz-Medina, A
2014-01-01
Citrinin is a toxic secondary metabolite first isolated from Penicillium citrinum, although is also produced by other species of Penicillium and Aspergillus. It has highly toxic, mutagenic, teratogenic and carcinogenic properties and is often found in crops, vegetables and fruit. To our knowledge there is no specific legislation on maximum levels permitted for citrinin, so no official analytical method is currently available for its determination. Our laboratory developed a fluorometric flow-through optosensor using Sephadex SPC-25 as solid support. Multi-commutated flow injection analysis was used for the construction of the manifold and for handling solutions. In this way, we minimised waste generation and human intervention, which are critical aspects when dealing with highly toxic compounds such as citrinin. The optimum excitation/emission wavelengths were set at 330/494 nm; the calibration curve was linear in the concentration range 35-900 ng ml⁻¹. A detection limit of 10.5 ng ml⁻¹ and relative standard deviations (RSDs) lower than 3% were obtained. The developed optosensor was applied to the determination of citrinin in rice and dietary supplements containing red yeast rice.
Fluorometric determination of the DNA concentration in municipal drinking water.
McCoy, W F; Olson, B H
1985-01-01
DNA concentrations in municipal drinking water samples were measured by fluorometry, using Hoechst 33258 fluorochrome. The concentration, extraction, and detection methods used were adapted from existing techniques. The method is reproducible, fast, accurate, and simple. The amounts of DNA per cell for five different bacterial isolates obtained from drinking water samples were determined by measuring DNA concentration and total cell concentration (acridine orange epifluorescence direct cell counting) in stationary pure cultures. The relationship between DNA concentration and epifluorescence total direct cell concentration in 11 different drinking water samples was linear and positive; the amounts of DNA per cell in these samples did not differ significantly from the amounts in pure culture isolates. We found significant linear correlations between DNA concentration and colony-forming unit concentration, as well as between epifluorescence direct cell counts and colony-forming unit concentration. DNA concentration measurements of municipal drinking water samples appear to monitor changes in bacteriological quality at least as well as total heterotrophic plate counting and epifluorescence direct cell counting. PMID:3890737
Longobardi, Francesco; Iacovelli, Vito; Catucci, Lucia; Panzarini, Giuseppe; Pascale, Michelangelo; Visconti, Angelo; Agostiano, Angela
2013-02-27
A new analytical method for the determination of ochratoxin A (OTA) in red wine has been developed by using a double-extract cleanup and a fluorometric measurement after spectral deconvolution. Wine samples were diluted with a solution containing 1% polyethylene glycol and 5% sodium hydrogencarbonate, filtered, and purified by immunoaffinity and aminopropyl solid-phase column. OTA contents in the purified extract were determined by a spectrofluorometer (excitation wavelength, 330 nm; emission wavelength, 470 nm) after deconvolution of fluorescence spectra. Average recoveries from wine samples spiked with OTA at levels ranging from 0.5 to 3.0 ng/mL were 94.5-105.4% with relative standard deviations (RSD) of <15% (n = 4). The limit of detection (LOD) was 0.2 ng/mL, and the total time of analysis was 30 min. The developed method was tested on 18 red wine samples (naturally contaminated and spiked with OTA at levels ranging from 0.4 to 3.0 ng/mL) and compared with AOAC Official Method 2001.01, based on immunoaffinity column cleanup and HPLC with fluorescence detector. A good correlation (r(2) = 0.9765) was observed between OTA levels obtained with the two methods, highlighting the reliability of the proposed method, the main advantage of which is the simple OTA determination by a benchtop fluorometer with evident reductions of cost and time of analysis.
Zhang, Changli; Han, Zhong; Wang, Mengjia; Yang, Zhenghao; Ran, Xueqin; He, Weijiang
2018-02-13
With a 4-aminostyryl group introduced at its 3-position, a BODIPY BDP-ODTAC was derived as a new ratiometric sensor for Ag + by modifying 4-amino group as a Ag + chelator, 1-oxa-4,10-dithia-7-azacyclododecane (ODTAC). In addition to the specific Ag + -induced hypsochromic absorption shift from 606 to 562 nm, this sensor demonstrated an excitation shift from 600 to 560 nm due to the internal charge transfer (ICT) effect endowed by the introduced α-4-aminostyryl group. The Ag + -induced recovery and enhancement of the intrinsic local emission band was also observed. The different sensing behavior of ODTAC-BDP with chelator ODTAC substituting on the meso-phenyl group infers that the ratiometric sensing behavior of BDP-ODTAC is correlated to the amino group in ODTAC acting as the electron donor for the ICT effect. With high Ag + selectivity over interfering cations such as Hg 2+ and Pb 2+ , BDP-ODTAC displays a fluorometric limit of detection (LOD) of ∼17 nM (∼0.002 ppm), which is distinctly lower than EPA and WHO standards for drinking water (500 nM, ∼0.055 ppm). Moreover, the BDP-ODTAC-doped PVC film shows the Ag + sensitivity of 1 ppm with a color switch from blue to purple, providing this sensor the ability to determine Ag + in totally aqueous solution sensitively via naked-eye detection.
Bahreyni, Amirhossein; Yazdian-Robati, Rezvan; Ramezani, Mohammad; Abnous, Khalil; Taghdisi, Seyed Mohammad
2018-04-29
A fluorometric aptamer-based assay was developed for ultrasensitive and selective determination of the neonicotinoid insecticide acetamiprid. The method is based on the use of an aptamer against acetamiprid, multiple complementary strands (CSs), and gold nanoparticles (AuNPs). It is found that by using different CSs, the sensitivity and selectivity of the method is enhanced. On addition of acetamiprid to the aptamer, they will bind to each other and CS1-fluorescein (FAM)-labeled CS2 (as a dsDNA) will be formed. The FAM-labeled dsDNA does not bind to the AuNPs (as a strong quencher) and remains free in the environment, resulting in a strong fluorescence intensity. Without the introduction of acetamiprid, FAM-labeled CS2 binds to AuNPs directly and indirectly through hybridization with CS3 immobilized on the surface of the AuNPs. So, the fluorescence intensity of FAM-labeled CS2 is significantly quenched by AuNPs. The method can detect acetamiprid in the 5 to 50 nM concentration range with a 2.8 nM detection limit. The assay was applied to the determination of acetamiprid in spiked tap water where is gave recoveries that ranged between 95.4% and 94.4%. Graphical abstract (a) In the presence of acetamiprid, aptamer interacts with acetamiprid. The formation of aptamer/acetamiprid causes pairing of complementary strand 1 with FAM-labeled complementary strand, leading to a strong fluorescence intensity. (b) In the absence of acetamiprid, aptamer is hybridized with complementary strand 1. Thus, a very weak fluorescence signal is detected.
Fluorometric method of quantitative cell mutagenesis
Dolbeare, Frank A.
1982-01-01
A method for assaying a cell culture for mutagenesis is described. A cell culture is stained first with a histochemical stain, and then a fluorescent stain. Normal cells in the culture are stained by both the histochemical and fluorescent stains, while abnormal cells are stained only by the fluorescent stain. The two stains are chosen so that the histochemical stain absorbs the wavelengths that the fluorescent stain emits. After the counterstained culture is subjected to exciting light, the fluorescence from the abnormal cells is detected.
Fluorometric method of quantitative cell mutagenesis
Dolbeare, F.A.
1980-12-12
A method for assaying a cell culture for mutagenesis is described. A cell culture is stained first with a histochemical stain, and then a fluorescent stain. Normal cells in the culture are stained by both the histochemical and fluorescent stains, while abnormal cells are stained only by the fluorescent stain. The two stains are chosen so that the histochemical stain absorbs the wavelengths that the fluorescent stain emits. After the counterstained culture is subjected to exciting light, the fluorescence from the abnormal cells is detected.
Graphene quantum dots for ultrasensitive detection of acetylcholinesterase and its inhibitors
NASA Astrophysics Data System (ADS)
Li, Nan; Wang, Xuewan; Chen, Jie; Sun, Lei; Chen, Peng
2015-09-01
Graphene quantum dots (GQDs) are emerging zero-dimensional materials promising a wide spectrum of novel applications including development of optical sensors. Herein, a GQD-based fluorometric sensor is devised to detect acetylcholinesterase (AChE, a critical enzyme in central nervous system and neuromuscular junctions) with an ultralow detection limit (0.58 pM with S/N of 5.0), using a photoluminescence ‘turn-off’ mechanism. This simple ‘mix-and-detect’ platform can also be employed to sense a variety of compounds that can directly or indirectly inhibit the enzymatic activities of AChE, such as nerve gases, pesticides, and therapeutic drugs. As the proof-of-concept demonstrations, we show the sensitive detection of paraoxon (a pesticide), tacrine (a drug to treat Alzheimer’s disease), and dopamine (an important neurotransmitter).
Rapid detection of trace amounts of surfactants using nanoparticles in fluorometric assays
NASA Astrophysics Data System (ADS)
Härmä, Harri; Laakso, Susana; Pihlasalo, Sari; Hänninen, Pekka; Faure, Bertrand; Rana, Subhasis; Bergström, Lennart
2010-01-01
Rapid microtiter assays that utilize the time-resolved fluorescence resonance energy transfer or quenching of dye-labeled proteins adsorbed onto the surfaces of polystyrene or maghemite nanoparticles have been developed for the detection and quantification of trace amounts of surfactants at concentrations down to 10 nM.Rapid microtiter assays that utilize the time-resolved fluorescence resonance energy transfer or quenching of dye-labeled proteins adsorbed onto the surfaces of polystyrene or maghemite nanoparticles have been developed for the detection and quantification of trace amounts of surfactants at concentrations down to 10 nM. Electronic supplementary information (ESI) available: Experimental details and Fig. S1 and S2. See DOI: 10.1039/b9nr00172g
Shi, Yupeng; Pan, Yi; Zhang, Heng; Zhang, Zhaomin; Li, Mei-Jin; Yi, Changqing; Yang, Mengsu
2014-06-15
Glutathione (GSH) plays key roles in biological systems and serves many cellular functions. Since biothiols all incorporate thiol, carboxylic and amino groups, discriminative detection of GSH over cysteine (Cys) and homocysteine (Hcy) is still challenging. We herein report a dual-mode nanosensor with both colorimetric and fluorometric readout based on carbon quantum dots and gold nanoparticles for discriminative detection of GSH over Cys/Hcy. The proposed sensing system consists of AuNPs and fluorescent carbon quantum dots (CQDs), where CQDs function as fluorometric reporter, and AuNPs serve a dual function as colorimetric reporter and fluorescence quencher. The mechanism of the nanosensor is based on two distance-dependent phenomenons, color change of AuNPs and FRET. Through controlling the surface properties of as-prepared nanoparticles, the addition of CQDs into AuNPs colloid solution might induce the aggregation of AuNPs and CQDs, leading to AuNPs color changing from red to blue and CQDs fluorescence quench. However, the presence of GSH can protect AuNPs from being aggregated and enlarge the inter-particle distance, which subsequently produces color change and fluorescent signal recovery. The nanosensor described in this report reflects on its simplicity and flexibility, where no further surface functionalization is required for the as-prepared nanoparticles, leading to less laborious and more cost-effective synthesis. The proposed dual-mode nanosensor demonstrated highly selectivity toward GSH, and allows the detection of GSH as low as 50 nM. More importantly, the nanosensor could not only function in aqueous solution for GSH detection with high sensitivity but also exhibit sensitive responses toward GSH in complicated biological environments, demonstrating its potential in bioanalysis and biodection, which might be significant in disease diagnosis in the future. Copyright © 2014 Elsevier B.V. All rights reserved.
Parodi, S; Abelmoschi, M L; Balbi, C; De Angeli, M T; Pala, M; Russo, P; Taningher, M; Santi, L
1989-11-01
Benzoin and caprolactam were examined for their capability of inducing alkaline DNA fragmentation in mouse and rat liver DNA after treatment in vivo. Three different methods were used. With the alkaline elution technique we measured an effect presumably related to the conformation of the DNA coil. With a viscometric and a fluorometric unwinding method we measured an effect presumably related to the number of unwinding points in DNA. For both compounds only the alkaline elution technique was clearly positive. The results suggest that both caprolactam and benzoin can induce an important change in the conformation of the DNA coil without inducing true breaks in DNA.
Aubertine, C. L.; Rivera, M.; Rohan, S. M.; Larone, D. H.
2006-01-01
The new VITEK 2 colorimetric card was compared to the previous fluorometric card for identification of yeast. API 20C was considered the “gold standard.” The new card consistently performed better than the older card. Isolates from CHROMagar Candida plates were identified equally as well as those from Sabouraud dextrose agar. PMID:16390976
Fluorometric Method for Determining the Efficiency of Spun-Glass Air Filtration Media
Sullivan, James F.; Songer, Joseph R.; Mathis, Raymond G.
1967-01-01
The procedures and equipment needed to measure filtration efficiency by means of fluorescent aerosols are described. The filtration efficiency of individual lots of spun-glass air filtration medium or of entire air filtration systems employing such media was determined. Data relating to the comparative evaluation of spun-glass filter media by means of the fluorometric method described, as well as by conventional biological procedures, are presented. PMID:6031433
Ribeiro, David S M; Prior, João A V; Taveira, Christian J M; Mendes, José M A F S; Santos, João L M
2011-06-15
In this work, and for the first time, it was developed an automatic and fast screening miniaturized flow system for the toxicological control of glibenclamide in beverages, with application in forensic laboratory investigations, and also, for the chemical control of commercially available pharmaceutical formulations. The automatic system exploited the multipumping flow (MPFS) concept and allowed the implementation of a new glibenclamide determination method based on the fluorometric monitoring of the drug in acidic medium (λ(ex)=301 nm; λ(em)=404 nm), in the presence of an anionic surfactant (SDS), promoting an organized micellar medium to enhance the fluorometric measurements. The developed approach assured good recoveries in the analysis of five spiked alcoholic beverages. Additionally, a good agreement was verified when comparing the results obtained in the determination of glibenclamide in five commercial pharmaceutical formulations by the proposed method and by the pharmacopoeia reference procedure. Copyright © 2011 Elsevier B.V. All rights reserved.
NASA Technical Reports Server (NTRS)
VanHeukelem, Laurie; Thomas, Crystal S.; Glibert, Patricia M.
2001-01-01
The need for accurate determination of chlorophyll a (chl a) is of interest for numerous reasons. From the need for ground-truth data for remote sensing to pigment detection for laboratory experimentation, it is essential to know the accuracy of the analyses and the factors potentially contributing to variability and error. Numerous methods and instrument techniques are currently employed in the analyses of chl a. These methods range from spectrophotometric quantification, to fluorometric analysis and determination by high performance liquid chromatography. Even within the application of HPLC techniques, methods vary. Here we provide the results of a comparison among methods and provide some guidance for improving the accuracy of these analyses. These results are based on a round-robin conducted among numerous investigators, including several in the Sensor Intercomparison and Merger for Biological and Interdisciplinary Oceanic Studies (SIMBIOS) and HyCODE Programs. Our purpose here is not to present the full results of the laboratory intercalibration; those results will be presented elsewhere. Rather, here we highlight some of the major factors that may contribute to the variability observed. Specifically, we aim to assess the comparability of chl a analyses performed by fluorometry and HPLC, and we identify several factors in the analyses which may contribute disproportionately to this variability.
DNAzyme based gap-LCR detection of single-nucleotide polymorphism.
Zhou, Li; Du, Feng; Zhao, Yongyun; Yameen, Afshan; Chen, Haodong; Tang, Zhuo
2013-07-15
Fast and accurate detection of single-nucleotide polymorphism (SNP) is thought more and more important for understanding of human physiology and elucidating the molecular based diseases. A great deal of effort has been devoted to developing accurate, rapid, and cost-effective technologies for SNP analysis. However most of those methods developed to date incorporate complicated probe labeling and depend on advanced equipment. The DNAzyme based Gap-LCR detection method averts any chemical modification on probes and circumvents those problems by incorporating a short functional DNA sequence into one of LCR primers. Two kinds of exonuclease are utilized in our strategy to digest all the unreacted probes and release the DNAzymes embedded in the LCR product. The DNAzyme applied in our method is a versatile tool to report the result of SNP detection in colorimetric or fluorometric ways for different detection purposes. Copyright © 2013 Elsevier B.V. All rights reserved.
Absorbance and fluorometric sensing with capillary wells microplates.
Tan, Han Yen; Cheong, Brandon Huey-Ping; Neild, Adrian; Liew, Oi Wah; Ng, Tuck Wah
2010-12-01
Detection and readout from small volume assays in microplates are a challenge. The capillary wells microplate approach [Ng et al., Appl. Phys. Lett. 93, 174105 (2008)] offers strong advantages in small liquid volume management. An adapted design is described and shown here to be able to detect, in a nonimaging manner, fluorescence and absorbance assays minus the error often associated with meniscus forming at the air-liquid interface. The presence of bubbles in liquid samples residing in microplate wells can cause inaccuracies. Pipetting errors, if not adequately managed, can result in misleading data and wrong interpretations of assay results; particularly in the context of high throughput screening. We show that the adapted design is also able to detect for bubbles and pipetting errors during actual assay runs to ensure accuracy in screening.
Detection and Characteristics of Rifampicin-Resistant Isolates of Mycobacterium tuberculosis.
Cherednichenko, A G; Dymova, M A; Solodilova, O A; Petrenko, T I; Prozorov, A I; Filipenko, M L
2016-03-01
Genotyping and analysis the drug resistance of 59 isolates of M. tuberculosis obtained from patients living in Altai Territory were performed using a BACTEC MGIT 960 fluorometric system by means of VNTR typing (variable number tandem repeat), PCR-RFLP analysis, and sequence analysis. The occurrence frequency was highest for isolates of the Beijing family (n=30, 50.8%). Analysis of mutation spectrum in the rpoB gene associated with rifampicin resistance revealed the major mutation (codon 531 of the rpoB gene) in 93% samples, which allows us to use rapid test systems.
Sensitive method to monitor trace quantities of benzanthrone in workers of dyestuff industries
DOE Office of Scientific and Technical Information (OSTI.GOV)
Joshi, A.; Khanna, S.K.; Singh, G.B.
1986-03-01
Dyestuff workers coming in contact with benzanthrone (an intermediate used for the synthesis of a variety of dyes) develop skin lesions, gastritis, liver malfunctions, and sexual disturbances. A highly sensitive fluorometric method to monitor trace quantities of benzanthrone in urine, serum, and biological tissues for experimental studies, has been developed. Coupled with simple extraction and resolution, optimum fluorescence is obtained in an equal mixture of chloroform:methanol, detecting as low as 2 ng benzanthrone. This method is approximately 250 times more sensitive than currently available colorimetric assay.
Gsponer, Natalia S; Rodríguez, María Claudia; Palacios, Rodrigo E; Chesta, Carlos A
2018-05-16
In this study, the phytoplankton structure of a freshwater reservoir located in central Argentina (Embalse Río Tercero) was analyzed using Beutler's method (Photosynthesis Research 72: 39-53, 2002), aiming to provide water quality control agencies with a reliable tool for early detection of algae blooms, particularly cyanobacteria. The method estimated the concentration of chlorophyll a (Chl a) contributed by individual algal groups in a real sample by fitting its fluorescence excitation spectrum to a linear combination of norm spectra of relevant algae groups. To this purpose, norm spectra for five algae genera usually found in Embalse Río Tercero, Microcystis, Chlorella, Cyclotella, Ceratium and Porphyridium, were constructed and posteriorly used to analyze samples collected in the reservoir in years 2014-2016. Results showed that the method worked well for the quick identification of the algae present in the samples, but it tended to overestimate its Chl a contents. This error was attributed to the large heterogeneity of the algal populations due to the aging of cells grown in environmental conditions. © 2018 The American Society of Photobiology.
NASA Astrophysics Data System (ADS)
Drake, Tyler K.; Robles, Francisco E.; DeSoto, Michael; Henderson, Marcus H.; Katz, David F.; Wax, Adam P.
2009-02-01
Microbicide gels are topical products that have recently been developed to combat sexually transmitted diseases including HIV/AIDS. The extent of gel coverage, thickness, and structure are crucial factors in gel effectiveness. It is necessary to be able to monitor gel distribution and behavior under various circumstances, such as coatis, and over an extended time scale in vivo. We have developed a multiplexed, Fourier-domain low coherence interferometry (LCI) system as a practical method of measuring microbicide gel distribution, with precision and accuracy comparable to currently used fluorometric techniques techniques. The multiplexed system achieved a broad scanning area without the need for a mechanical scanning device, typical of OCT systems, by utilizing six parallel channels with simultaneous data collection. We now propose an imaging module which will allow the integration of the multiplexed LCI system into the current fluorescence system in conjunction with an endoscope. The LCI imaging module will meet several key criteria in order to be compatible with the current system. The fluorescent system features a 4-mm diameter rigid endsoscope enclosed in a 27-mm diameter polycarbonate tube, with a water immersion tip. Therefore, the LCI module must be low-profile as well as water-resistant to fit inside the current design. It also must fulfill its primary function of delivering light from each of the six channels to the gel and collecting backscattered light. The performance of the imaging module will be characterized by scanning a calibration socket which contains grooves of known depths, and comparing these measurements to the fluorometric results.
NASA Astrophysics Data System (ADS)
Hutterer, Rudi
2018-01-01
The author discusses methods for the fluorometric determination of affinity constants by linear and nonlinear fitting methods. This is outlined in particular for the interaction between cyclodextrins and several anesthetic drugs including benzocaine. Special emphasis is given to the limitations of certain fits, and the impact of such studies on enzyme-substrate interactions are demonstrated. Both the experimental part and methods of analysis are well suited for students in an advanced lab.
Briciu-Burghina, Ciprian; Heery, Brendan; Regan, Fiona
2015-09-07
E. coli β-glucuronidase (GUS) activity assays are routinely used in fields such as plant molecular biology, applied microbiology and healthcare. Methods based on the optical detection of GUS using synthetic fluorogenic substrates are widely employed since they don't require expensive instrumentation and are easy to perform. In this study three fluorogenic substrates and their respective fluorophores were studied for the purpose of developing a continuous fluorometric method for GUS. The fluorescence intensity of 6-chloro-4-methyl-umbelliferone (6-CMU) at pH 6.8 was found to be 9.5 times higher than that of 4-methyl umbelliferone (4-MU) and 3.2 times higher than the fluorescence of 7-hydroxycoumarin-3-carboxylic acid (3-CU). Michaelis-Menten kinetic parameters of GUS catalysed hydrolysis of 6-chloro-4-methyl-umbelliferyl-β-D-glucuronide (6-CMUG) were determined experimentally (Km = 0.11 mM, Kcat = 74 s(-1), Kcat/Km = 6.93 × 10(5) s(-1) M(-1)) and compared with the ones found for 4-methyl-umbelliferyl-β-D-glucuronide (4-MUG) (Km = 0.07 mM, Kcat = 92 s(-1), Kcat/Km = 1.29 × 10(6) s(-1) M(-1)) and 3-carboxy-umbelliferyl-β-D-glucuronide (3-CUG) (Km = 0.48 mM, Kcat = 35 s(-1), Kcat/Km = 7.40 × 10(4) s(-1) M(-1)). Finally a continuous fluorometric method based on 6-CMUG as a fluorogenic substrate has been developed for measuring GUS activity. When compared with the highly used discontinuous method based on 4-MUG as a substrate it was found that the new method is more sensitive and reproducible (%RSD = 4.88). Furthermore, the developed method is less laborious, faster and more economical and should provide an improved alternative for GUS assays and kinetic studies.
Fluorometric graphene oxide-based detection of Salmonella enteritis using a truncated DNA aptamer.
Chinnappan, Raja; AlAmer, Saleh; Eissa, Shimaa; Rahamn, Anas Abdel; Abu Salah, Khalid M; Zourob, Mohammed
2017-12-18
The work describes a fluorescence-based study for mapping the highest affinity truncated aptamer from the full length sequence and its integration in a graphene oxide platform for the detection of Salmonella enteriditis. To identify the best truncated sequence, molecular beacons and a displacement assay design are applied. In the fluorescence displacement assay, the truncated aptamer was hybridized with fluorescein and quencher-labeled complementary sequences to form a fluorescence/quencher pair. In the presence of S. enteritidis, the aptamer dissociates from the complementary labeled oligonucleotides and thus, the fluorescein/quencher pair becomes physically separated. This leads to an increase in fluorescence intensity. One of the truncated aptamers identified has a 2-fold lower dissociation constant (3.2 nM) compared to its full length aptamer (6.3 nM). The truncated aptamer selected in this process was used to develop a fluorometric graphene oxide (GO) based assay. If fluorescein-labeled aptamer is adsorbed on GO via π stacking interaction, fluorescence is quenched. However, in the presence of target (S. enteriditis), the labeled aptamers is released from surface to form a stable complex with the bacteria and fluorescence is restored, depending on the quantity of bacteria being present. The resulting assay has an unsurpassed detection limit of 25 cfu·mL -1 in the best case. The cross reactivity to Salmonella typhimurium, Staphylococcus aureus and Escherichia coli is negligible. The assay was applied to analyze doped milk samples for and gave good recovery. Thus, we believe that the truncated aptamer/graphene oxide platform is a potential tool for the detection of S. Enteritidis. Graphical abstract Fluorescently labelled aptamer against Salmonella enteritidis was adsorbed on the surface of graphene oxide by π-stacking interaction. This results in quenching of the fluorescence of the label. Addition of Salmonella enteritidis restores fluorescence, and this effect is used for quantification of this food-borne pathogen.
Determination of lithium in rocks: Fluorometric method
White, C.E.; Fletcher, M.H.; Parks, J.
1951-01-01
The gravimetric method in general use for the determination of lithium is tedious, and the final weighed product often contains other alkali metals. A fluorometric method was developed to shorten the time required for the analysis and to assure that the final determination is for lithium alone. This procedure is based on the complex formed between lithium and 8-hydroxyquinoline. The fluorescence is developed in a slightly alkaline solution of 95% alcohol and measurement is made on a photoelectric fluorometer. Separation from the ore is carried out by the wet method or by the distillation procedure. Sodium and potassium are removed by alcohol and ether, but complete separation is not necessary. Comparison of analyzed samples shows excellent agreement with spectrographic and gravimetric methods. The fluorometric method is more rapid than the gravimetric and produces more conclusive results. Another useful application is in the preparation of standard lithium solutions from reagent quality salts when a known standard is available. In this case no separations are necessary.
In vitro effects of doxorubicin and tetrathiomolybdate on canine hemangiosarcoma cells.
Sloan, Caroline Q; Rodriguez, Carlos O
2018-02-01
OBJECTIVE To assess the in vitro effects of doxorubicin and tetrathiomolybdate (TM) on cells from a canine hemangiosarcoma cell line. SAMPLE Cultured cells from the canine hemangiosarcoma-derived cell line DEN-HSA. PROCEDURES Cells were treated with TM (0 to 1.5μM), doxorubicin (0 to 5μM), or both with or without 24 hours of pretreatment with ascorbic acid (750μM). Degree of cellular cytotoxicity was measured with a colorimetric assay. Long-term growth inhibition was assessed with a 10-day colony-formation assay. Induction of apoptosis was quantitated by fluorometric assessment of caspase-3 and -7 activation. Formation of reactive oxygen species (ROS) was also detected fluorometrically. RESULTS Exposure of cells to the combination of TM and doxorubicin resulted in a greater decrease in proliferation and clonogenic survival rates than exposure to each drug alone. This treatment combination increased ROS formation and apoptosis to a greater extent than did doxorubicin or TM alone. Ascorbic acid inhibited both TM-induced ROS formation and apoptosis. CONCLUSIONS AND CLINICAL RELEVANCE Results suggested that the enhancement in cytotoxic effects observed with DEN-HSA cell exposure to the combination of doxorubicin and TM was achieved through an increase in ROS production. These findings provide a rationale for a clinical trial of this treatment combination in dogs with hemangiosarcoma.
Absorbance and fluorometric sensing with capillary wells microplates
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tan, Han Yen; Cheong, Brandon Huey-Ping; Neild, Adrian
2010-12-15
Detection and readout from small volume assays in microplates are a challenge. The capillary wells microplate approach [Ng et al., Appl. Phys. Lett. 93, 174105 (2008)] offers strong advantages in small liquid volume management. An adapted design is described and shown here to be able to detect, in a nonimaging manner, fluorescence and absorbance assays minus the error often associated with meniscus forming at the air-liquid interface. The presence of bubbles in liquid samples residing in microplate wells can cause inaccuracies. Pipetting errors, if not adequately managed, can result in misleading data and wrong interpretations of assay results; particularly inmore » the context of high throughput screening. We show that the adapted design is also able to detect for bubbles and pipetting errors during actual assay runs to ensure accuracy in screening.« less
Paz, Beatriz; Riobó, Pilar; Fernández, M Luisa; Fraga, Santiago; Franco, José M
2004-09-01
The presence of YTX was confirmed in Protoceratium reticulatum cultures and detected for the first time in Lingulodinium polyedrum cultures, mainly in the cells but also, to a lesser extent, dissolved in the culture medium. The production of yessotoxins (YTXs) by cultures of different strains of P. reticulatum and L. polyedrum was studied with liquid chromatography coupled to fluorometric detection using the dienophile reagent DMEQ-TAD and liquid chromatography-mass spectrometry. When comparing toxin production at different stages of culture growth, larger amounts of toxins were observed in the cellular fraction and in the culture medium at the last stage of the culture (day 21) in both species. Although YTX was detected in culture medium, with this study it was not possible to explain which is the release mechanism of the toxin in the medium.
NASA Astrophysics Data System (ADS)
Mitsubayashi, Kohji; Chien, Po-Jen; Ye, Ming; Suzuki, Takuma; Toma, Koji; Arakawa, Takahiro
2016-11-01
A fluorometric acetone biosniffer (biochemical gas sensor) for assessment of lipid metabolism utilizing reverse reaction of secondary alcohol dehydrogenase was constructed and evaluated. The biosniffer showed highly sensitivity and selectivity for continuous monitoring of gaseous acetone. The measurement of breath acetone concentration during fasting and aerobic exercise were also investigated. The acetone biosniffer provides a novel analytical tool for noninvasive evaluation of human lipid metabolism and it is also expected to use for the clinical and physiological applications such as monitoring the progression of diabetes.
Reverse phase protein microarrays: fluorometric and colorimetric detection.
Gallagher, Rosa I; Silvestri, Alessandra; Petricoin, Emanuel F; Liotta, Lance A; Espina, Virginia
2011-01-01
The Reverse Phase Protein Microarray (RPMA) is an array platform used to quantitate proteins and their posttranslationally modified forms. RPMAs are applicable for profiling key cellular signaling pathways and protein networks, allowing direct comparison of the activation state of proteins from multiple samples within the same array. The RPMA format consists of proteins immobilized directly on a nitrocellulose substratum. The analyte is subsequently probed with a primary antibody and a series of reagents for signal amplification and detection. Due to the diversity, low concentration, and large dynamic range of protein analytes, RPMAs require stringent signal amplification methods, high quality image acquisition, and software capable of precisely analyzing spot intensities on an array. Microarray detection strategies can be either fluorescent or colorimetric. The choice of a detection system depends on (a) the expected analyte concentration, (b) type of microarray imaging system, and (c) type of sample. The focus of this chapter is to describe RPMA detection and imaging using fluorescent and colorimetric (diaminobenzidine (DAB)) methods.
Arakawa, Takahiro; Sato, Toshiyuki; Iitani, Kenta; Toma, Koji; Mitsubayashi, Kohji
2017-04-18
Various volatile organic compounds can be found in human transpiration, breath and body odor. In this paper, a novel two-dimensional fluorometric imaging system, known as a "sniffer-cam" for ethanol vapor released from human breath and palm skin was constructed and validated. This imaging system measures ethanol vapor concentrations as intensities of fluorescence through an enzymatic reaction induced by alcohol dehydrogenase (ADH). The imaging system consisted of multiple ultraviolet light emitting diode (UV-LED) excitation sheet, an ADH enzyme immobilized mesh substrate and a high-sensitive CCD camera. This imaging system uses ADH for recognition of ethanol vapor. It measures ethanol vapor by measuring fluorescence of nicotinamide adenine dinucleotide (NADH), which is produced by an enzymatic reaction on the mesh. This NADH fluorometric imaging system achieved the two-dimensional real-time imaging of ethanol vapor distribution (0.5-200 ppm). The system showed rapid and accurate responses and a visible measurement, which could lead to an analysis of metabolism function at real time in the near future.
"Naked-eye" colorimetric and "turn-on" fluorometric chemosensors for reversible Hg2+ detection.
Wanichacheva, Nantanit; Praikaew, Panida; Suwanich, Thanapat; Sukrat, Kanjarat
2014-01-24
Two new Hg(2+)-colorimetric and fluorescent sensors based on 2-[3-(2-aminoethylsulfanyl) propylsulfanyl]ethanamine covalently bound to one and two units of rhodamine-6G moieties, 1 and 2, were synthesised, and their sensing behaviors toward metal ions were investigated by UV/Vis and fluorescence spectroscopy. Upon the addition of Hg(2+), the sensors exhibited highly sensitive "turn-on" fluorescence enhancement as well as a color change from colorless to pink, which was readily noticeable for naked eye detection. Especially, 1 exhibited the reversible behavior and revealed a very high selectivity in the presence of competitive ions, particularly Cu(2+), Ag(+), Pb(2+), Ca(2+), Cd(2+), Co(2+), Fe(2+), Mn(2+), Na(+), Ni(2+), K(+), Ba(2+), Li(+) and Zn(2+), with a low detection limit of 1.7 ppb toward Hg(2+). Copyright © 2013 Elsevier B.V. All rights reserved.
“Naked-eye” colorimetric and “turn-on” fluorometric chemosensors for reversible Hg2+ detection
NASA Astrophysics Data System (ADS)
Wanichacheva, Nantanit; Praikaew, Panida; Suwanich, Thanapat; Sukrat, Kanjarat
2014-01-01
Two new Hg2+-colorimetric and fluorescent sensors based on 2-[3-(2-aminoethylsulfanyl) propylsulfanyl]ethanamine covalently bound to one and two units of rhodamine-6G moieties, 1 and 2, were synthesised, and their sensing behaviors toward metal ions were investigated by UV/Vis and fluorescence spectroscopy. Upon the addition of Hg2+, the sensors exhibited highly sensitive “turn-on” fluorescence enhancement as well as a color change from colorless to pink, which was readily noticeable for naked eye detection. Especially, 1 exhibited the reversible behavior and revealed a very high selectivity in the presence of competitive ions, particularly Cu2+, Ag+, Pb2+, Ca2+, Cd2+, Co2+, Fe2+, Mn2+, Na+, Ni2+, K+, Ba2+, Li+ and Zn2+, with a low detection limit of 1.7 ppb toward Hg2+.
Sun, Xiaolong; Lacina, Karel; Ramsamy, Elena C; Flower, Stephen E; Fossey, John S; Qian, Xuhong; Anslyn, Eric V; Bull, Steven D; James, Tony D
2015-05-01
Using the self-assembly of aromatic boronic acids with Alizarin Red S (ARS), we developed a new chemosensor for the selective detection of peroxynitrite. Phenylboronic acid (PBA), benzoboroxole (BBA) and 2-( N , N -dimethylaminomethyl)phenylboronic acid (NBA) were employed to bind with ARS to form the complex probes. In particular, the ARS-NBA system with a high binding affinity can preferably react with peroxynitrite over hydrogen peroxide and other ROS/RNS due to the protection of the boron via the solvent-insertion B-N interaction. Our simple system produces a visible colorimetric change and on-off fluorescence response towards peroxynitrite. By coupling a chemical reaction that leads to an indicator displacement, we have developed a new sensing strategy, referred to herein as RIA (Reaction-based Indicator displacement Assay).
Xu, Ai-Zhen; Zhang, Li; Zeng, Hui-Hui; Liang, Ru-Ping; Qiu, Jian-Ding
2018-05-09
A fluorometric method is described for the determination of the activity of alkaline phosphatase (ALP). It relies on the competition between gold nanoparticles (AuNPs) and pyrophosphate (PPi) for the coordination sites on the surface of CePO 4 :Tb nanorods. The green fluorescence of the CePO 4 :Tb is reduced in the presence of AuNPs due to fluorescence resonance energy transfer (FRET), but can be restored on addition of PPi due to the stronger affinity of PPi to the CePO 4 :Tb. In the presence of ALP, PPi is hydrolyzed to form phosphate which has much weaker affinity for the CePO 4 :Tb. Hence, the AuNPs will reassemble on the CePO 4 :Tb, and fluorescence is reduced. Fluorescence drops linearly in the 0.2 to 100 U·L -1 activity range, and the detection limit is 60 mU·L -1 (at S/N = 3). The method does not require any modification of the surface of the CePO 4 :Tb and is highly sensitive and selective. The inhibition of ALP activity by Na 3 VO 4 was also studied. In our perception, the method may find application in the diagnosis of ALP-related diseases, in screening for inhibitors, and in studies on ALP-related functions in biological systems. Graphical abstract A assay for the detection of alkaline phosphatase is proposed based on the fluorescence resonance energy transfer between CePO 4 :Tb and AuNPs. It relies on the competitive binding of AuNPs and pyrophosphate (PPi) to CePO 4 :Tb and the hydrolysis of PPi by ALP.
Selvaggini, Roberto; Servili, Maurizio; Urbani, Stefania; Esposto, Sonia; Taticchi, Agnese; Montedoro, GianFrancesco
2006-04-19
Hydrophilic phenols are the most abundant natural antioxidants of virgin olive oil (VOO), in which tocopherols and carotenes are also present. The prevalent classes of hydrophilic phenols found in VOO are phenyl alcohols, phenolic acids, secoiridoids such as the dialdehydic form of decarboxymethyl elenolic acid linked to (3,4-dihydroxyphenyl)ethanol or (p-hydroxypheny1)ethanol (3,4-DHPEA-EDA or p-HPEA-EDA) and an isomer of the oleuropein aglycon (3,4-DHPEA-EA), lignans such as (+)-1-acetoxypinoresinol and (+)-pinoresinol, and flavonoids. A new method for the analysis of VOO hydrophilic phenols by direct injection in high-performance liquid chromatography (HPLC) with the use of a fluorescence detector (FLD) has been proposed and compared with the traditional liquid-liquid extraction technique followed by the HPLC analysis utilizing a diode array detector (DAD) and a FLD. Results show that the most important classes of phenolic compounds occurring in VOO can be evaluated using HPLC direct injection. The efficiency of the new method, as compared to the liquid-liquid extraction, was higher to quantify phenyl alcohols, lignans, and 3,4-DHPEA-EA and lower for the evaluation of 3,4-DHPEA-EDA and p-HPEA-EDA.
Duan, Nuo; Wu, Shijia; Zhang, Huiling; Zou, Ying; Wang, Zhouping
2018-05-18
An F 0 F 1 -ATPase-based aptasensor is described for the fluorometric determination of Vibrio parahaemolyticus. Chromatophores containing F 0 F 1 -ATPases were first prepared from Rhodospirillum rubrum cells. Then, an aptamer-functionalized chromatophore acts as the capture probe, and a chromatophore labeled with the pH probe fluorescein acts as the signalling probe. In the presence of V. parahaemolyticus, the rotation rate of F 0 F 1 -ATPase is decreased due to the formation of the aptamer-chromatophore complex. This leads to a retarded proton flux out of the chromatophores. As a result, the pH value inside the chromatophores is reduced, and the fluorescence of the pH probe F1300 is accordingly decreased. The relative fluorescence varies linearly over the 15 to 1.5 × 10 6 cfu·mL -1 Vibrio parahaemolyticus concentration range, and the limit of detection is 15 cfu·mL -1 . The method was applied to analyze artificially contaminated salmon samples where it showed excellent perfomance. Graphical abstract In this assay, aptamer functionalized chromatophores act as a capture probe, and the fluoresce in labeled chromatophores as signalling probe. The formation of aptamer-chromatophore complex leads to a retarded proton flux out of the chromatophores. As a result, the pH value inside the chromatophores is reduced, and fluorescence intensity is accordingly decreased.
Application of a fluorometric microplate algal toxicity assay for riverine periphytic algal species.
Nagai, Takashi; Taya, Kiyoshi; Annoh, Hirochica; Ishihara, Satoru
2013-08-01
Although riverine periphytic algae attached to riverbed gravel are dominant species in flowing rivers, there is limited toxicity data on them because of the difficulty in cell culture and assays. Moreover, it is well known that sensitivity to pesticides differ markedly among species, and therefore the toxicity data for multiple species need to be efficiently obtained. In this study, we investigated the use of fluorometric microplate toxicity assay for testing periphytic algal species. We selected five candidate test algal species Desmodesmus subspicatus, Achnanthidium minutissimum, Navicula pelliculosa, Nitzschia palea, and Pseudanabaena galeata. The selected species are dominant in the river, include a wide range of taxon, and represent actual species composition. Other additional species were also used to compare the sensitivity and suitability of the microplate assay. A 96-well microplate was used as a test chamber and algal growth was measured by in-vivo fluorescence. Assay conditions using microplate and fluorometric measurement were established, and sensitivities of 3,5-dichlorophenol as a reference substance were assayed. The 50 percent effect concentrations (EC50s) obtained by fluorometric microplate assay and those obtained by conventional Erlenmeyer flask assay conducted in this study were consistent. Moreover, the EC50 values of 3,5-dichlorophenol were within the reported confidence intervals in literature. These results supported the validity of our microplate assay. Species sensitivity distribution (SSD) analysis was conducted using the EC50s of five species. The SSD was found to be similar to the SSD obtained using additional tested species, suggesting that SSD using the five species largely represents algal sensitivity. Our results provide a useful and efficient method for high-tier probabilistic ecological risk assessment of pesticides. Copyright © 2013 Elsevier Inc. All rights reserved.
Bagheri, Nafiseh; Khataee, Alireza; Habibi, Biuck; Hassanzadeh, Javad
2018-03-01
Here, Ag nanoparticle/flake-like Zn-based MOF nanocomposite (AgNPs@ZnMOF) with great peroxidase-like activity was applied as an efficient support for molecularly imprinted polymer (MIP) and successfully used for selective determination of patulin. AgNPs@ZnMOF was simply synthesized by creating Ag nanoparticles (Ag NPs) inside the nano-pores of flake-like (Zn)MOF. The high surface area of MOF remarkably improved the catalytic activity of Ag NPs which was assessed by fluorometric, colorimetric and electrochemical techniques. Furthermore, it was observed that patulin could strangely reduce the catalytic activity of AgNPs@ZnMOF, probably due to its electron capturing features. This outcome was the motivation to design an assay for patulin detection. In order to make a selective interaction with patulin molecules, MIP layer was created on the surface of AgNPs@ZnMOF by co-polymerization reaction of 3-aminopropyl triethoxysilane (APTES) and tetraethyl orthosilicate (TEOS) monomers wherein patulin was applied as template agent. Combination between the selective identifying feature of MIP and outstanding peroxidase-like activity of novel AgNPs@ZnMOF nanocomposite as well as the sensitive fluorescence detection system was led to the design of a reliable probe for patulin. The prepared MIP-capped AgNPs@ZnMOF catalyzed the H 2 O 2 -terephthalic acid reaction which produced a high florescent product. In the presence of patulin, the fluorescence intensity was decreased proportional to its concentration in the range of 0.1-10µmolL -1 with a detection limit of 0.06µmolL -1 . The proposed method was able to selectively measure patulin in a complex media without significant interfering effects from analogue compounds. Copyright © 2017 Elsevier B.V. All rights reserved.
Fluorescent Probes for Single-Step Detection and Proteomic Profiling of Histone Deacetylases.
Xie, Yusheng; Ge, Jingyan; Lei, Haipeng; Peng, Bo; Zhang, Huatang; Wang, Danyang; Pan, Sijun; Chen, Ganchao; Chen, Lanfang; Wang, Yi; Hao, Quan; Yao, Shao Q; Sun, Hongyan
2016-12-07
Histone deacetylases (HDACs) play important roles in regulating various physiological and pathological processes. Developing fluorescent probes capable of detecting HDAC activity can help further elucidate the roles of HDACs in biology. In this study, we first developed a set of activity-based fluorescent probes by incorporating the Kac residue and the O-NBD group. Upon enzymatic removal of the acetyl group in the Kac residue, the released free amine reacted intramolecularly with the O-NBD moiety, resulting in turn-on fluorescence. These designed probes are capable of detecting HDAC activity in a continuous fashion, thereby eliminating the extra step of fluorescence development. Remarkably, the amount of turn-on fluorescence can be as high as 50-fold, which is superior to the existing one-step HDAC fluorescent probes. Inhibition experiments further proved that the probes can serve as useful tools for screening HDAC inhibitors. Building on these results, we moved on and designed a dual-purpose fluorescent probe by introducing a diazirine photo-cross-linker into the probe. The resulting probe was not only capable of reporting enzymatic activity but also able to directly identify and capture the protein targets from the complex cellular environment. By combining a fluorometric method and in-gel fluorescence scanning technique, we found that epigenetic readers and erasers can be readily identified and differentiated using a single probe. This is not achievable with traditional photoaffinity probes. In light of the prominent properties and the diverse functions of this newly developed probe, we envision that it can provide a robust tool for functional analysis of HDACs and facilitate future drug discovery in epigenetics.
Davarani, Saied Saeed Hosseiny; Moazami, Hamid Reza; Keshtkar, Ali Reza; Banitaba, Mohammad Hossein; Nojavan, Saeed
2013-06-14
A novel method for the selective electromembrane extraction (EME) of U(6+) prior to fluorometric determination has been proposed. The effect of extraction conditions including supported liquid membrane (SLM) composition, extraction time and extraction voltage were investigated. An SLM composition of 1% di-2-ethyl hexyl phosphonic acid in nitrophenyl octyl ether (NPOE) showed good selectivity, recovery and enrichment factor. The best performance was achieved at an extraction potential of 80 volts and an extraction time of 14 minutes Under the optimized conditions, a linear range from 1 to 1000 ng mL(-1) and LOD of 0.1 ng mL(-1) were obtained for the determination of U(6+). The EME method showed good performance in sample cleanup and the reduction of the interfering effects of Mn(2+), Zn(2+), Cd(2+), Ni(2+), Fe(3+), Co(2+), Cu(2+), Cl(-) and PO4(3-) ions during fluorometric determination of uranium in real water samples. The recoveries above 54% and enrichment factors above 64.7 were obtained by the proposed method for real sample analysis. Copyright © 2013 Elsevier B.V. All rights reserved.
Boyle, R T; Oliveira, L F; Bianchini, A; Souza, M M
2013-03-01
We used immunocytochemical and fluorometric techniques to show that gill cells of two marine invertebrates, the crab Neohelice granulata (osmoregulator) and the clam Mesodesma mactroides (osmoconformer), increase the expression of membrane transporters [Na(+)/K(+)-ATPase and aquaporin (AQP1)] after whole-animals exposure (96 h) to sublethal concentrations of copper in water of salinity 30 ppt, when both clams and crabs are isosmotic with respect to the environmental medium. A plausible interpretation of our findings is that this increased expression in membrane transporters may serve as an attempt to ameliorate the deleterious effects of copper on the mechanisms involved in ion and volume regulation in gill cells.
Tips on the analysis of phosphatidic acid by the fluorometric coupled enzyme assay.
Hassaninasab, Azam; Han, Gil-Soo; Carman, George M
2017-06-01
The fluorometric coupled enzyme assay to measure phosphatidic acid (PA) involves the solubilization of extracted lipids in Triton X-100, deacylation, and the oxidation of PA-derived glycerol-3-phosphate to produce hydrogen peroxide for conversion of Amplex Red to resorufin. The enzyme assay is sensitive, but plagued by high background fluorescence from the peroxide-containing detergent and incomplete heat inactivation of lipoprotein lipase. These problems affecting the assay reproducibility were obviated by the use of highly pure Triton X-100 and by sufficient heat inactivation of the lipase enzyme. The enzyme assay could accurately measure the PA content from the subcellular fractions of yeast cells. Copyright © 2017 Elsevier Inc. All rights reserved.
A G-quadruplex-based Label-free Fluorometric Aptasensor for Adenosine Triphosphate Detection.
Li, Li Juan; Tian, Xue; Kong, Xiang Juan; Chu, Xia
2015-01-01
A G-quadruplex-based, label-free fluorescence assay was demonstrated for the detection of adenosine triphosphate (ATP). A double-stranded DNA (dsDNA), hybridized by ATP-aptamer and its complementary sequence, was employed as a substrate for ATP binding. SYBR Green I (SG I) was a fluorescent probe and exonuclease III (Exo III) was a nuclease to digest the dsDNA. Consequently, in the absence of ATP, the dsDNA was inset with SG I and was digested by Exo III, resulting in a low background signal. In the presence of ATP, the aptamer in dsDNA folded into a G-quadruplex structure that resisted the digestion of Exo III. SG I was inserted into the structure, showing high fluorescence. Owing to a decrease of the background noise, a high signal-to-noise ratio could be obtained. This sensor can detect ATP with a concentration ranging from 50 μM to 5 mM, and possesses a capacity for the sensitive determination of other targets.
Feng, Jia; Duan, Li Xin; Shang, Zhuo Bin; Chao, Jian Bin; Wang, Yu; Jin, Wei Jun
2018-05-04
A new julolidine based Schiff base receptor (L) was synthesized and characterized. L forms a 1:1 complex with Al 3+ in methanol, resulting in an immediate color change from chartreuse to orange and a remarkable enhancement in its emission intensity along with a bathochromic shift from 540 nm to 570 nm. Addition of trace amounts of water significantly quenches the fluorescence emission, where a decomplexation of Al 3+ from the L-Al 3+ complex takes place. The significant quenching effect indicated that the L-Al 3+ ensemble system can be used to detect trace water in commercial methanol. From the fluorescence titration, the detection limit for sensing water in methanol was estimated to be 0.0047%. We have also made an easy-to-prepare test strip of L-Al 3+ to detect water in methanol through naked-eye observation, which is possible to realize in situ monitoring. Copyright © 2018 Elsevier B.V. All rights reserved.
Wang, Lingyun; Fang, Guipo; Cao, Derong
2014-11-01
A novel BODIPY-based probe 1 was designed and synthesized as a selective fluorescent and colorimetric chemosensor for fluoride. The spectral responses of 1 to fluoride in acetonitrile were studied: an approximately 118 nm red shift in absorption and 'turn-off' emission response was observed. The striking pink to indigo change in ambient light was thought to be due to the deprotonation of the phenol moiety by way of O-H · · · F hydrogen bonding interactions. Interestingly, when the nonfluorescent 1-F(-) solution treated with trifluoroacetic acid (TFA) resulted in color change from indigo to pink and a significant enhancement of fluorescence intensity (10-fold). Furthermore, the reversibility and reusability of probe 1 for the detection of F(-) ion was tested for four cycles indicating the probe 1 could be used in reversible manner.
Wong, C Kwan; Wong, C Kim
2003-09-01
A red tide was detected in the inner parts of Tolo Harbour, Hong Kong, in November 2000. Water samples were collected from a fixed station at the centre of the red tide patch for microscopic analysis of phytoplankton community composition and high performance liquid chromatography (HPLC) analysis of phytoplankton pigments. At the peak of the red tide on 24 November 2000, phytoplankton was dominated by the dinoflagellate Scrippsiella trochoidea. The red tide began to decline at the end of November and, by 1 December 2000, the phytoplankton was dominated by diatoms. Chlorophylls and carotenoids in water samples were analysed using HPLC pigment separation technique. Dinoflagellates were indicated by the signature pigment peridinin. Significant correlation (r=0.999) was found between the peridinin concentration and dinoflagellate density. A decrease in peridinin and an increase in fucoxanthin, a major carotenoid in diatoms, marked the shift in phytoplankton composition at the end of the red tide. HPLC analysis also revealed the occurrence of minor phytoplankton groups that are difficult to identify by light microscopy. Red tide monitoring and study of red tide dynamics in Hong Kong have been based on cell counting and spectrophotometric or fluorometric measurement of chlorophyll a. HPLC pigment analysis provides an effective alternative for investigating phytoplankton dynamics during red tide and other algal blooms.
Miyake, Mayo; Nakajima, Hizuru; Hemmi, Akihide; Yahiro, Masayuki; Adachi, Chihaya; Soh, Nobuaki; Ishimatsu, Ryoichi; Nakano, Koji; Uchiyama, Katsumi; Imato, Toshihiko
2012-07-15
The performance of an organic thin film photodiode (OPD), fabricated from a hetero-junction comprised of two layers of C(60) and a phthalocyanine-Cu(II) complex was evaluated by detecting the chemiluminescence generated from the reaction of luminol with horseradish peroxidase in the presence of H(2)O(2), and the fluorescence from resorufin, as an optical detector. The photocurrent of the OPD was linear with respect to the power of light from a commercial LED. The sensitivity of the OPD was sufficient for detecting chemiluminescence with a power 0.1μW/cm(2). The OPD was successfully used in a flow-immunoassay for IgA, a marker of human stress, in which a sandwich immunoassay was carried out on the microchip and the fluorescence from resorufin, produced by the enzymatic reaction, was detected. The detection limits for resorufin and IgA were 5.0μM and 16ng/mL, respectively. The photosensitivity of the OPD remained relatively constant for a minimum of one year. Copyright © 2012 Elsevier B.V. All rights reserved.
Shaily; Kumar, Ajay; Parveen, Iram; Ahmed, Naseem
2018-06-01
Exposure to even very low concentrations of Pb 2+ is known to cause cardiovascular, neurological, developmental, and reproductive disorders, and affects children in particular more severely. Consequently, much effort has been dedicated to the development of colorimetric and fluorescent sensors that can selectively detect Pb 2+ ions. Here, we describe the development of a triazole-based fluorescent sensor L5 for Pb 2+ ion detection. The fluorescence intensity of chemosensor L5 was selectively quenched by Pb 2+ ions and a clear color change from colorless to yellow could be observed by the naked eye. Chemosensor L5 exhibited high sensitivity and selectivity towards Pb 2+ ions in phosphate-buffered solution [20 mM, 1:9 DMSO/H 2 O (v/v), pH 8.0] with a 1:1 binding stoichiometry, a detection limit of 1.9 nM and a 6.76 × 10 6 M -1 binding constant. Additionally, low-cost and easy-to-prepare test strips impregnated with chemosensor L5 were also produced for efficient of Pb 2+ detection and proved the practical use of this test. Copyright © 2018 John Wiley & Sons, Ltd.
Herrera, D; Monaga, M; Campos, D; Pampín, Y; González, E C; Lavaut, K
2013-01-01
Gaucher disease (GD) is a lysosomal storage disorder characterized by a deficiency of the lysosomal acid β-D-glucosidase (GBA). The aim of this study was to develop an ultramicro-fluorometric assay based on the method of Chamoles et al. for determining GBA activity in dried blood spots on filter paper (DBS). The assay used 3-mm diameter blood spot and 8 mmol/l of 4-methylumbelliferyl-β-D-glucoside as enzymatic substrate. The reaction occurred in plates incubated at 37°C for 20 hours and the enzyme activity was expressed in μmol hydrolysed substrate/l blood/h. The fluorescence of the enzyme product was automatically measured in a fluorometer-photometer reader (SUMA Technology). The intra and inter-assay coefficients of variation were lower than 9 and 12%, respectively, and the recovery range was 97-109%.Three patients with GD were correctly diagnosed using the ultramicroassay. Healthy newborn DBS samples (n = 3003) from the National Neonatal Screening Program were analyzed, and the mean GBA activity was 5.7 μmol/l blood/h. Our assay showed high Pearson (n = 26; r = 0.99) and concordance correlations (ρc = 0.99) with the traditional method described by Chamoles et al. The analytical performance characteristics of our ultramicro-fluorometric assay suggest that it can be used in the diagnosis of GD in newborns and adults.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Perdian, D.C.; Cha, Sangwon; Oh, Jisun
2010-03-18
Mass spectrometric imaging has been utilized to localize individual astrocytes and to obtain cholesterol populations at the single-cell level in laser desorption ionization (LDI) with colloidal silver. The silver ion adduct of membrane-bound cholesterol was monitored to detect individual cells. Good correlation between mass spectrometric and optical images at different cell densities indicates the ability to perform single-cell studies of cholesterol abundance. The feasibility of quantification is confirmed by the agreement between the LDI-MS ion signals and the results from a traditional enzymatic fluorometric assay. We propose that this approach could be an effective tool to study chemical populations atmore » the cellular level.« less
Fluorometric assay for phenotypic differentiation of drug-resistant HIV mutants
Zhu, Qinchang; Yu, Zhiqiang; Kabashima, Tsutomu; Yin, Sheng; Dragusha, Shpend; El-Mahdy, Ahmed F. M.; Ejupi, Valon; Shibata, Takayuki; Kai, Masaaki
2015-01-01
Convenient drug-resistance testing of viral mutants is indispensable to effective treatment of viral infection. We developed a novel fluorometric assay for phenotypic differentiation of drug-resistant mutants of human immunodeficiency virus-I protease (HIV-PR) which uses enzymatic and peptide-specific fluorescence (FL) reactions and high-performance liquid chromatography (HPLC) of three HIV-PR substrates. This assay protocol enables use of non-purified enzyme sources and multiple substrates for the enzymatic reaction. In this study, susceptibility of HIV mutations to drugs was evaluated by selective formation of three FL products after the enzymatic HIV-PR reaction. This proof-of-concept study indicates that the present HPLC-FL method could be an alternative to current phenotypic assays for the evaluation of HIV drug resistance. PMID:25988960
NASA Astrophysics Data System (ADS)
Shahabadi, Nahid; Khorshidi, Aref; Moghadam, Neda Hossinpour
2013-10-01
In the present investigation, an attempt has been made to study the interaction of zonisamide (ZNS) with the transport protein, human serum albumin (HSA) employing UV-Vis, fluorometric, circular dichroism (CD) and molecular docking techniques. The results indicated that binding of ZNS to HSA caused strong fluorescence quenching of HSA through static quenching mechanism, hydrogen bonds and van der Waals contacts are the major forces in the stability of protein ZNS complex and the process of the binding of ZNS with HSA was driven by enthalpy (ΔH = -193.442 kJ mol-1). The results of CD and UV-Vis spectroscopy showed that the binding of this drug to HSA induced conformational changes in HSA. Furthermore, the study of molecular docking also indicated that zonisamide could strongly bind to the site I (subdomain IIA) of HSA mainly by hydrophobic interaction and there were hydrogen bond interactions between this drug and HSA, also known as the warfarin binding site.
Tao, Yu; Lin, Youhui; Huang, Zhenzhen; Ren, Jinsong; Qu, Xiaogang
2012-01-15
An easy prepared fluorescence turn-on and colorimetric dual channel probe was developed for rapid assay of Hg(2+) ions with high sensitivity and selectivity by using poly(acrylic acid)-templated silver nanoclusters (PAA-AgNCs). The PAA-AgNCs exhibited weak fluorescence, while upon the addition of Hg(2+) ions, AgNCs gives a dramatic increase in fluorescence as a result of the changes of the AgNCs states. The detection limit was estimated to be 2 nM, which is much lower than the Hg(2+) detection requirement for drinking water of U.S. Environmental Protection Agency, and the turn-on sensing mode offers additional advantage to efficiently reduce background noise. Also, a colorimetric assay of Hg(2+) ions can be realized due to the observed absorbance changes of the AgNCs. More importantly, the method was successfully applied to the determination of Hg(2+) ions in real water samples, which suggests our proposed method has a great potential of application in environmental monitoring. Copyright © 2011 Elsevier B.V. All rights reserved.
Ultraviolet, Visible, and Fluorescence Spectroscopy
NASA Astrophysics Data System (ADS)
Penner, Michael H.
Spectroscopy in the ultraviolet-visible (UV-Vis) range is one of the most commonly encountered laboratory techniques in food analysis. Diverse examples, such as the quantification of macrocomponents (total carbohydrate by the phenol-sulfuric acid method), quantification of microcomponents, (thiamin by the thiochrome fluorometric procedure), estimates of rancidity (lipid oxidation status by the thiobarbituric acid test), and surveillance testing (enzyme-linked immunoassays), are presented in this text. In each of these cases, the analytical signal for which the assay is based is either the emission or absorption of radiation in the UV-Vis range. This signal may be inherent in the analyte, such as the absorbance of radiation in the visible range by pigments, or a result of a chemical reaction involving the analyte, such as the colorimetric copper-based Lowry method for the analysis of soluble protein.
Capillary electrophoresis of conidia from cultivated microscopic filamentous fungi.
Horká, Marie; Růzicka, Filip; Kubesová, Anna; Holá, Veronika; Slais, Karel
2009-05-15
In immunocompromised people fungal agents are able to cause serious infections with high mortality rate. An early diagnosis can increase the chances of survival of the affected patients. Simultaneously, the fungi produce toxins and they are frequent cause of allergy. Currently, various methods are used for detection and identification of these pathogens. They use microscopic examination and growth characteristic of the fungi. New methods are based on the analysis of structural elements of the target microorganisms such as proteins, polysaccharides, glycoproteins, nucleic acids, etc. for the construction of antibodies, probes, and primers for detection. The above-mentioned methods are time-consuming and elaborate. Here hydrophobic conidia from the cultures of different strains of the filamentous fungi were focused and separated by capillary zone electrophoresis and capillary isoelectric focusing. The detection was optimized by dynamic modifying of conidia by the nonionogenic tenside on the basis of pyrenebutanoate. Down to 10 labeled conidia of the fungal strains were fluorometrically detected, and isoelectric points of conidia were determined. The observed isoelectric points were compared with those obtained from the separation of the cultured clinical samples, and they were found to be not host-specific.
Li, Jingwen; Li, Xinming; Shi, Xiujuan; He, Xuewen; Wei, Wei; Ma, Nan; Chen, Hong
2013-10-09
We describe here a simple fluorometric assay for the highly sensitive detection of caspase-3 activities on the basis of the inner-filter effect of gold nanoparticles (AuNPs) on CdTe quantum dots (QDs). The method takes advantage of the high molar absorptivity of the plasmon band of gold nanoparticles as well as the large absorption band shift from 520 to 680 nm upon nanoparticle aggregation. When labeled with a peptide possessing the caspase-3 cleavage sequence (DEVD), the monodispersed Au-Ps (peptide-modified AuNPs) exhibited a tendency to aggregate when exposed to caspase-3, which induced the absorption band transition from 520 to 680 nm and turned on the fluorescence of the CdTe QDs for caspase-3 sensing. Under optimum conditions, a high sensitivity towards caspase-3 was achieved with a detection limit as low as 18 pM, which was much lower than the corresponding assays based on absorbance or other approaches. Overall, we demonstrated a facile and sensitive approach for caspase-3 detection, and we expected that this method could be potentially generalized to design more fluorescent assays for sensing other bioactive entities.
Fluorometric determination of nitrite in cured meats.
Coppola, E D; Wickroski, A F; Hanna, J G
1975-05-01
An indirect fluorometric method for determining sodium nitrite in meat products is presented. The extracted sodium nitrite is consumed in a diazotization reaction with a measured excess of sulfanilic acid. Fluorescamine, which acts selectively with primary amines such as sulfanilic acid, is a fluorogenic reagent for the excess amine. The amine consumed, calculated by difference from the total originally present, is directly related to the sodium nitrite content of the sample. Interferences from amino acids and soluble proteins in the meat extract are eliminated by judicious use of a secondary peak in the fluorescence spectra (436 nm excitation, 495 nm fluorescence) combined with measurement at low pH (3.30). The recoveries of sodium nitrite ranged from 83.2 to 99.6% with an average of 93.4 and a standard deviation of +/- 5.28% for 11 determinations.
Schwab, Karen; Lauber, Jennifer; Hesse, Friedemann
2016-01-01
The glycosyltransferase HisDapGalNAcT2 is the key protein of the Escherichia coli (E. coli) SHuffle® T7 cell factory which was genetically engineered to allow glycosylation of a protein substrate in vivo. The specific activity of the glycosyltransferase requires time-intensive analytics, but is a critical process parameter. Therefore, it has to be monitored closely. This study evaluates fluorometric in situ monitoring as option to access this critical process parameter during complex E. coli fermentations. Partial least square regression (PLS) models were built based on the fluorometric data recorded during the EnPresso® B fermentations. Capable models for the prediction of glucose and acetate concentrations were built for these fermentations with rout mean squared errors for prediction (RMSEP) of 0.19 g·L−1 and 0.08 g·L−1, as well as for the prediction of the optical density (RMSEP 0.24). In situ monitoring of soluble enzyme to cell dry weight ratios (RMSEP 5.5 × 10−4 µg w/w) and specific activity of the glycosyltransferase (RMSEP 33.5 pmol·min−1·µg−1) proved to be challenging, since HisDapGalNAcT2 had to be extracted from the cells and purified. However, fluorescence spectroscopy, in combination with PLS modeling, proved to be feasible for in situ monitoring of complex expression systems. PMID:28952595
Krivanek, Peter; Koppatz, Karl; Turnheim, Klaus
2003-06-01
A rapid and low-cost assay for simultaneous vigabatrin (VGA) and gabapentin (GBP) determination is described that can be performed with simple HPLC instrumentation. The method involves derivatization of the primary amine group of VGA and GBP with dansyl chloride followed by isocratic separation (column: microBondapak C-18, 10 microm, 300 x 3.9 mm; mobile phase: 50 mmol/L NaH(2)PO(4) in 40% acetonitrile) at 50 degrees C and fluorometric detection (excitation and emission wavelength: 318 and 510 nm, respectively) of the fluorescent product, which is stable for at least 7 days. Correlation coefficients of the calibration curves are >0.999 with a lower limit of detection of 0.3 microg/mL. Between- and within-run coefficients of variation are below 4.5%, and assay time is 15 minutes. This method may be used for therapeutic drug monitoring in the case of GBP and to control patient compliance in the case of VGA.
Sakaguchi, Yohei; Yoshida, Hideyuki; Todoroki, Kenichiro; Nohta, Hitoshi; Yamaguchi, Masatoshi
2009-06-15
We have developed a new and simple method based on "fluorous derivatization" for LC of native fluorescent compounds. This method involves the use of a column with a fluorous stationary phase. Native fluorescent analytes with target functional groups are precolumn derivatized with a nonfluorescent fluorous tag, and the fluorous-labeled analytes are retained in the column, whereas underivatized substances are not. Only the retained fluorescent analytes are detected fluorometrically at appropriate retention times, and retained substrates without fluorophores are not detected. In this study, biologically important carboxylic acids (homovanillic acid, vanillylmandelic acid, and 5-hydroxyindoleacetic acid) and drugs (naproxen, felbinac, flurbiprofen, and etodolac) were used as model native fluorescent compounds. Experimental results indicate that the fluorous-phase column can selectively retain fluorous compounds including fluorous-labeled analytes on the basis of fluorous separation. We believe that separation-oriented derivatization presented here is the first step toward the introduction of fluorous derivatization in quantitative LC analysis.
Nitric Oxide Analyzer Quantification of Plant S-Nitrosothiols.
Hussain, Adil; Yun, Byung-Wook; Loake, Gary J
2018-01-01
Nitric oxide (NO) is a small diatomic molecule that regulates multiple physiological processes in animals, plants, and microorganisms. In animals, it is involved in vasodilation and neurotransmission and is present in exhaled breath. In plants, it regulates both plant immune function and numerous developmental programs. The high reactivity and short half-life of NO and cross-reactivity of its various derivatives make its quantification difficult. Different methods based on calorimetric, fluorometric, and chemiluminescent detection of NO and its derivatives are available, but all of them have significant limitations. Here we describe a method for the chemiluminescence-based quantification of NO using ozone-chemiluminescence technology in plants. This approach provides a sensitive, robust, and flexible approach for determining the levels of NO and its signaling products, protein S-nitrosothiols.
Perdian, D C; Cha, Sangwon; Oh, Jisun; Sakaguchi, Donald S; Yeung, Edward S; Lee, Young Jin
2010-04-30
Mass spectrometric imaging has been utilized to localize individual astrocytes and to obtain cholesterol populations at the single-cell level in laser desorption ionization (LDI) with colloidal silver. The silver ion adduct of membrane-bound cholesterol was monitored to detect individual cells. Good correlation between mass spectrometric and optical images at different cell densities indicates the ability to perform single-cell studies of cholesterol abundance. The feasibility of quantification is confirmed by the agreement between the LDI-MS ion signals and the results from a traditional enzymatic fluorometric assay. We propose that this approach could be an effective tool to study chemical populations at the cellular level. Published in 2010 by John Wiley & Sons, Ltd.
A fluorometric paper-based sensor array for the discrimination of heavy-metal ions.
Feng, Liang; Li, Hui; Niu, Li-Ya; Guan, Ying-Shi; Duan, Chun-Feng; Guan, Ya-Feng; Tung, Chen-Ho; Yang, Qing-Zheng
2013-04-15
A fluorometric paper-based sensor array has been developed for the sensitive and convenient determination of seven heavy-metal ions at their wastewater discharge standard concentrations. Combining with nine cross-reactive BODIPY fluorescent indicators and array technologies-based pattern-recognition, we have obtained the discrimination capability of seven different heavy-metal ions at their wastewater discharge standard concentrations. After the immobilization of indicators and the enrichment of analytes, identification of the heavy-metal ions was readily acquired using a standard chemometric approach. Clear differentiation among heavy-metal ions as a function of concentration was also achieved, even down to 10(-7)M. A semi-quantitative estimation of the heavy-metal ion concentration was obtained by comparing color changes with a set of known concentrations. The sensor array was tentatively investigated in spiked tap water and sea water, and showed possible feasibility for real sample testing. Copyright © 2013 Elsevier B.V. All rights reserved.
Seo, Minjeong; Park, Dong-Hoon; Lee, Chan Woo; Jaworski, Justyn; Kim, Jong-Man
2016-01-01
Much of atmospheric water originates from transpiration, the process by which plants release H2O from pores, known as stomata, that simultaneously intake CO2 for photosynthesis. Controlling stomatal aperture can regulate the extent of water transport in response to dynamic environmental factors including osmotic stress, temperature, light, and wind. While larger leaf regions are often examined, the extent of water vapor release from individual stomata remains unexplored. Using a “brush-on” sensing material, we can now assess transpiration using a water-responsive, polydiacetylene-based coating on the leaves surfaces. By eliciting a fluorometric signal to passing water vapor, we obtained information regarding the activity of individual stomata. In this demonstration, our results prove that this coating can identify the proportion of active stomata and the extent of transpirational diffusion of water in response to different conditions. PMID:27578430
NASA Astrophysics Data System (ADS)
Xiaoyan, Zhou; Yuanyuan, Jiang; Zaijun, Li; Zhiguo, Gu; Guangli, Wang
2016-08-01
Graphene quantum dots (GQDs) have received extensive concern in many fields such as optical probe, bioimaging and biosensor. However, few reports refer on the influence of GQDs on enzyme performance. The paper reports two kinds of graphene quantum dots (termed as GO-GQDs and N,S-GQDs) that were prepared by cutting of graphene oxide and pyrolysis of citric acid and L-cysteine, and their use for the horse radish peroxidase (HRP) modification. The study reveals that GO-GQDs and N,S-GQDs exhibit an opposite effect on the HRP performance. Only HRP modified with GO-GQDs offers an enhanced activity (more than 1.9 times of pristine enzyme) and thermo-stability. This is because GO-GQDs offer a larger conjugate rigid plane and fewer hydrophilic groups compared to N,S-GQDs. The characteristics can make GO-GQDs induce a proper conformational change in the HRP for the catalytic performance, improving the enzyme activity and thermo-stability. The HRP modified with green luminescent GO-GQDs was also employed as a biocatalyst for sensing of H2O2 by a fluorometric sensor. The colorless tetramethylbenzidine (TMB) is oxidized into blue oxidized TMB in the presence of H2O2 by the assistance of HRP/GO-GQDs, leading to an obvious fluorescence quenching. The fluorescence intensity linearly decreases with the increase of H2O2 concentration in the range from 2 × 10 - 9 to 2 × 10 - 4 M with the detection limit of 6.8 × 10 - 10 M. The analytical method provides the advantage of sensitivity, stability and accuracy compared with present H2O2 sensors based on the pristine HRP. It has been successfully applied in the determination of H2O2 in real water samples. The study also opens a new avenue for modification of enzyme activity and stability that offers great promise in applications such as biological catalysis, biosensing and enzyme engineering.
Sista, Ramakrishna S; Eckhardt, Allen E; Wang, Tong; Graham, Carrie; Rouse, Jeremy L; Norton, Scott M; Srinivasan, Vijay; Pollack, Michael G; Tolun, Adviye A; Bali, Deeksha; Millington, David S; Pamula, Vamsee K
2011-10-01
Newborn screening for lysosomal storage diseases (LSDs) has been gaining considerable interest owing to the availability of enzyme replacement therapies. We present a digital microfluidic platform to perform rapid, multiplexed enzymatic analysis of acid α-glucosidase (GAA) and acid α-galactosidase to screen for Pompe and Fabry disorders. The results were compared with those obtained using standard fluorometric methods. We performed bench-based, fluorometric enzymatic analysis on 60 deidentified newborn dried blood spots (DBSs), plus 10 Pompe-affected and 11 Fabry-affected samples, at Duke Biochemical Genetics Laboratory using a 3-mm punch for each assay and an incubation time of 20 h. We used a digital microfluidic platform to automate fluorometric enzymatic assays at Advanced Liquid Logic Inc. using extract from a single punch for both assays, with an incubation time of 6 h. Assays were also performed with an incubation time of 1 h. Assay results were generally comparable, although mean enzymatic activity for GAA using microfluidics was approximately 3 times higher than that obtained using bench-based methods, which could be attributed to higher substrate concentration. Clear separation was observed between the normal and affected samples at both 6- and 1-h incubation times using digital microfluidics. A digital microfluidic platform compared favorably with a clinical reference laboratory to perform enzymatic analysis in DBSs for Pompe and Fabry disorders. This platform presents a new technology for a newborn screening laboratory to screen LSDs by fully automating all the liquid-handling operations in an inexpensive system, providing rapid results.
Wei, Yanli; Chen, Yanxia; Li, Huanhuan; Shuang, Shaomin; Dong, Chuan; Wang, Gufeng
2015-01-15
A novel aptamer-based label-free assay for sensitive and selective detection of ATP was developed. This assay employs a new aptamer/fluorescent probe system that shows resistance to exonuclease I (Exo I) digestion upon binding to ATP molecules. In the absence of ATP, the complex between the ATP-binding aptamer (ATP-aptamer) and a DNA binding dye, berberine, is digested upon the addition of exonuclease I, leading to the release of berberine into solution and consequently, quenched berberine fluorescence. In the presence of ATP, the ATP-binding aptamer folds into a G-quadruplex structure that is resistant to Exo I digestion. Accordingly, berberine is protected in the G-quadruplex structure and high fluorescence intensity is observed. As such, based on the fluorescence signal change, a label-free fluorescence assay for ATP was developed. Factors affecting the analysis of ATP including the concentration of ATP-binding aptamer, reaction time, temperature and the concentration of Exo I were comprehensively investigated. Under optimal conditions, the fluorescence intensity of the sensing system displayed a response for ATP in a wide range up to 17.5 mM with a detection limit of 140 nM.
Wang, Yinan; Chan, Wan
2014-06-25
Nephrotoxic and carcinogenic aristolochic acids (AAs) are naturally occurring nitrophenanthrene carboxylic acids in the herbal genus Aristolochia. The misuse of AA-containing herbs in preparing slimming drugs has caused hundred of cases of kidney disease in Belgium women in a slimming regime in the early 1990s. Accumulating evidence also suggested that prolong dietary intake of AA-contaminated food is one of the major causes to the Balkan endemic nephropathy that was first observed in the late 1950s. Therefore, analytical methods of high sensitivity are extremely important for safeguarding human exposure to AA-containing herbal medicines, herbal remedies, and food composites. In this paper, we describe the development of a new high-performance liquid chromatography coupled fluorescence detector (HPLC-FLD) method for the sensitive determination of AAs. The method makes use of a novel cysteine-induced denitration reaction that "turns on" the fluorescence of AAs for fluorometric detections. Our results showed that the combination of cysteine-induced denitration and HPLC-FLD analysis allows for sensitive quantification of AA-I and AA-II at detection limits of 27.1 and 25.4 ng/g, respectively. The method was validated and has been successfully applied in quantifying AAs in Chinese herbal medicines.
A pyrene formulation for fluorometric visualization of latent fingermarks
NASA Astrophysics Data System (ADS)
Kumari Sharma, Kirti; Harsha Kannikanti, Gavash; Ramachandra Rao Baggi, Tulsidas; Rao Vaidya, Jayathirtha
2018-07-01
Present work is conducted to demonstrate the use of pyrene for the development of latent fingermarks. Pyrene formulation with binders can be efficiently used for developing latent fingermarks on porous, non-porous and semi-porous surfaces. The effectiveness of pyrene formulation for the detection of latent fingermarks present on a large variety of objects was systematically and comparatively carried out. To optimize the working formulation, studies were carried out using different pyrene concentrations followed by various substrate study, time dependent study, temperature study, depleted fingermark development and the stability of the proposed formulation. When illuminated at 366 nm, the developed fingermarks showed clear, high contrast primary, secondary and tertiary level ridge details. This work reveals that the fluorescent molecules having high quantum yield are a versatile fluorescent label and can find their applications in forensic latent fingermark development.
Peptide-cellulose conjugates for protease point of care diagnostics and treatment
USDA-ARS?s Scientific Manuscript database
Peptide-cellulose conjugates containing Human Neutrophil Elastase substrate sequences with both colorimetric and fluorometric signal molecules have been synthesized on a variety of cellulosic and nanocellulosic substrates including cotton and wood nanocrystals, wood nanocomposites, cotton-based aero...
Yilmaz, Bilal; Arslan, Sakir
2016-03-01
A simple, rapid and sensitive high-performance liquid chromatography (HPLC) method has been developed to quantify carvedilol in human plasma using an isocratic system with fluorescence detection. The method included a single-step liquid-liquid extraction with diethylether and ethylacetate mixture (3 : 1, v/v). HPLC separation was carried out by reversed-phase chromatography with a mobile phase composed of 20 mM phosphate buffer (pH 7)-acetonitrile (65 : 35, v/v), pumped at a flow rate of 1.0 mL/min. Fluorescence detection was performed at 240 nm (excitation) and 330 nm (emission). The calibration curve for carvedilol was linear from 10 to 250 ng/mL. Intra- and interday precision values for carvedilol in human plasma were <4.93%, and accuracy (relative error) was better than 4.71%. The analytical recovery of carvedilol from human plasma averaged out to 91.8%. The limits of detection and quantification of carvedilol were 3.0 and 10 ng/mL, respectively. Also, the method was successfully applied to three patients with hypertension who had been given an oral tablet of 25 mg carvedilol. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Yang, Xiaolan; Hu, Xiaolei; Xu, Bangtian; Wang, Xin; Qin, Jialin; He, Chenxiong; Xie, Yanling; Li, Yuanli; Liu, Lin; Liao, Fei
2014-06-17
A fluorometric titration approach was proposed for the calibration of the quantity of monoclonal antibody (mcAb) via the quench of fluorescence of tryptophan residues. It applied to purified mcAbs recognizing tryptophan-deficient epitopes, haptens nonfluorescent at 340 nm under the excitation at 280 nm, or fluorescent haptens bearing excitation valleys nearby 280 nm and excitation peaks nearby 340 nm to serve as Förster-resonance-energy-transfer (FRET) acceptors of tryptophan. Titration probes were epitopes/haptens themselves or conjugates of nonfluorescent haptens or tryptophan-deficient epitopes with FRET acceptors of tryptophan. Under the excitation at 280 nm, titration curves were recorded as fluorescence specific for the FRET acceptors or for mcAbs at 340 nm. To quantify the binding site of a mcAb, a universal model considering both static and dynamic quench by either type of probes was proposed for fitting to the titration curve. This was easy for fitting to fluorescence specific for the FRET acceptors but encountered nonconvergence for fitting to fluorescence of mcAbs at 340 nm. As a solution, (a) the maximum of the absolute values of first-order derivatives of a titration curve as fluorescence at 340 nm was estimated from the best-fit model for a probe level of zero, and (b) molar quantity of the binding site of the mcAb was estimated via consecutive fitting to the same titration curve by utilizing such a maximum as an approximate of the slope for linear response of fluorescence at 340 nm to quantities of the mcAb. This fluorometric titration approach was proved effective with one mcAb for six-histidine and another for penicillin G.
Lu, Yan; Li, Xiang; Wang, Gongke; Tang, Wen
2013-01-15
The detection of Pb(2+) with DNA-based biosensor is usually susceptible to severe interference from Hg(2+) because of the T-Hg(2+)-T interaction between Hg(2+) and T residues. In this study, we developed a rapid, sensitive, selective and label-free sensor for the detection of Pb(2+) in the presence of Hg(2+) based on the Pb(2+)-induced G-quadruplex formation with cationic water-soluble conjugated polymer (PMNT) as a "polymeric stain" to transduce optical signal. We selected a specific sequence oligonucleotide, TBAA (5'-GGAAGGTGTGGAAGG-3'), which can form a G-quadruplex structure upon the addition of Pb(2+). This strategy provided a promising alternative to Pb(2+) determination in the presence of Hg(2+) instead of the universal masking agents of Hg(2+) (such as CN(-), SCN(-)). Based on this observation, a simple "mix-and-detect" optical sensor for the detection of Pb(2+) was proposed due to the distinguishable optical properties of PMNT-ssDNA and PMNT-(G-quadruplex) complexes. By this method, we could identify micromolar Pb(2+) concentrations within 5min even with the naked eye. Furthermore, the detection limit was improved to the nanomolar range by the fluorometric method. We also successfully utilized this biosensor for the determination of Pb(2+) in tap water samples. Copyright © 2012 Elsevier B.V. All rights reserved.
Liu, Ting; Li, Na; Dong, Jiang Xue; Zhang, Ying; Fan, Yu Zhu; Lin, Shu Min; Luo, Hong Qun; Li, Nian Bing
2017-01-15
A bidimensional optical sensing platform which combines the advantages of fluorescence and colorimetry has been designed for arginine (Arg) detection. The system was established by monitoring the influence of Arg on the growth of gold nanoparticles/carbon quantum dots (Au/CQDs) composite, and the CQDs synthesized by ethylene glycol were used as the reducing and stabilizing agent in this paper. Considering that Arg is the only amino acid with guanidine group and has the highest isoelectric point (pI) value at 10.76, Arg would carry positive charges at pH 7.4. Consequently, the positively charged guanidine group of Arg could attract AuCl 4 - and CQDs through electrostatic interaction, which inhibited the growth of Au/CQDs composite. Thereby, the color of the system almost did not change and the fluorescence quenching of CQDs was prevented in the presence of Arg. Based on the color change a low detection limit for Arg was 37nM, and a detection limit of 450nM was obtained by fluorescence spectroscopy. Moreover, this dual-signal sensor also revealed excellent selectivity toward Arg over other amino acids. Besides, Arg can be detected in urine samples with satisfactory results, which demonstrate the potential applications for real analysis. Copyright © 2016 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chu, F.S.
1988-05-12
1) A new direct ELISA, which involves the use of a generic type antibody for T-2 toxin and 3-acetyl-neosolaniol-hemisuccinate (3-Ac-NEOS-HS) conjugated to horseradish peroxidase for the analysis of T-2 toxin metabolites, was established. 2) Analysis of 5 metabolites, i.e., T-2 toxin, HT-2, T-2-4ol, 3'-OH-HT-2, NEOS and a mixture of these five toxins, added at toxin concentrations of 50 and 200 ng/mL of urine, revealed that 87% of the added toxins were recovered analytically at both concentrations in the ELISA, and 69% in RIA and the 200 ppb level. 3) A series of monkey urine samples obtained from a metabolic studymore » was subjected to the new ELISA protocol was as well as to RIA. 4) An extensive study to evaluate a fluorometric method, i.e., hit-and-run assay was made. 5) A direct ELISA for deoxynivalenol (DON) was established. 6) Further improvements for the ELISA for saxitoxin were made. 7) New approaches to produce antibody against nivalenol and saxitoxin were made, but the antibody titers were low. 8) Antibody against microcystin (MCS) was obtained from rabbits after immunizing the animals with MCS-BSA conjugate. 9) A chemical method for the preparation of different monoacetoxyscirpenol (MAS) was established. 10) Routine preparation of different immunochemical reagents continued. Phytotoxins Biological warfare agents; Dinoflagellates. (AW)« less
LacI(Ts)-Regulated Expression as an In Situ Intracellular Biomolecular Thermometer▿
McCabe, K. M.; Lacherndo, E. J.; Albino-Flores, I.; Sheehan, E.; Hernandez, M.
2011-01-01
In response to needs for in situ thermometry, a temperature-sensitive vector was adapted to report changes in the intracellular heat content of Escherichia coli in near-real time. This model system utilized vectors expressing increasing quantities of β-galactosidase in response to stepwise temperature increases through a biologically relevant range (22 to 45°C). As judged by calibrated fluorometric and colorimetric reporters, both whole E. coli cells and lysates expressed significant repeatable changes in β-galactosidase activity that were sensitive to temperature changes of less than 1°C (35 to 45°C). This model system suggests that changes in cellular heat content can be detected independently of the medium in which cells are maintained, a feature of particular importance where the medium is heterogeneous or nonaqueous, or otherwise has a low heat transfer capacity. We report here that the intracellular temperature can be reliably obtained in near-real time using reliable fluorescent reporting systems from cellular scales, with a 20°C range of detection and at least 0.7°C sensitivity between 35 and 45°C. PMID:21378059
NASA Astrophysics Data System (ADS)
Chattopadhyay, Tanmay; Chatterjee, Sourav; Majumder, Ishani; Ghosh, Soumen; Yoon, Sangee; Sim, Eunji
2018-04-01
Three Schiff base ligands such as 2-[(2-Hydroxy-3-methoxy-benzylidene)-amino]-2-hydroxymethyl-propane-1,3-diol (HL1), 2-[(2-Hydroxy-benzylidene)-amino]-2-hydroxymethyl-propane-1,3-diol (HL2), 2-[(3,5-Dichloro-2-hydroxy-benzylidene)-amino]-2-hydroxymethyl-propane-1,3-diol (HL3) have been synthesized by condensation of aldehydes (such as 3,5-Dichloro-2-hydroxy benzaldehyde, 2-Hydroxy-benzaldehyde, and 2-Hydroxy-3-methoxy-benzaldehyde) with Tris-(hydroxymethyl)amino methane and characterized by IR, UV-vis and 1H NMR spectroscopy. Then all these three ligands have been used to prepare Pb(II) complexes by reaction with lead(II) acetate tri-hydrate in methanol. In view of analytical and spectral (IR, UV-vis and Mass) studies, it has been concluded that, except HL2, other two ligands form 1:1 metal complexes (1 and 3) with lead. Between two complexes, complex 3 is highly fluorescent and this property has been used to identify the pollutant nitroaromatics. Finally, the quenching mechanism has been established by means of spectroscopic investigation.
A flurorometric screening method was used to estimate total polycyclic aromatic hydrocarbon concentrations in sediments collected from the St. Louis River Area of Concern in northeastern Minnesota. Sediments were collected as part of a Regional Environmental Monitoring and Asses...
FORTRAN PROCESSING OF FLUOROMETRIC DATA LOGGED BY A TURNER DESIGNS FIELD FLUOROMETER
Continuous recording of dye fluorescence using field fluorometers at selected sampling sites facilitate acquisition of real-time dye-tracing data. The Turner Designs Model 10-AU-005 Field Fluorometer allows for frequent fluorescence readings, data logging, and easy downloading t...
Measurement of atmospheric OH by titration of near-IR fluorescent dyes
NASA Technical Reports Server (NTRS)
Betterton, Eric A.; Gast, Karl
1994-01-01
Recent research has shown that certain polymethine dyes can be detected at ultratrace levels (greater than or equal to 6x10(exp -14) M) in solution by fluorimetry. These detection limits are possible because of the inherent sensitivity of fluorescence techniques, because the dyes fluoresce in the near infrared region where background interference is negligible, and because powerful infrared diode lasers are now available to improve the signal to noise ratio. Other work has shown that the hydroxyl radical destroys the ability of polymethine dyes to fluoresce. These observations form the basis for a new hydroxyl radical detector that is essentially a fluorometric titrator. Theoretically, the detector should show an acceptable sensitivity and response time. Assuming that the atmospheric HO concentration is about 10(exp -11) moles m(exp -3) (i.e. 10(exp 6) molecules cm(exp -3)), then 10 L of air 'titrated' with 20 mL of 10(exp -11) M dye solution (an easily detected concentration) should result in a drop in the fluorescent signal of 50 percent - a readily detectable change. At a flow rate of 3 L min(exp -1) the sampling time would be 3 minutes. The biggest potential problem is selectivity: other oxidants may also cause the fluorescence signal to be lost. The chemistry of polymethine dyes has not been studied in detail and so no quantitative data are available. However, a survey of the literature suggests that in general HO should react up to six orders of magnitude faster than HO2 and other radicals such as RO2 and RO. It should also react much more rapidly than H2O2 and O3. Thus it may be possible to discriminate kinetically against potential interfering substances. It was shown in the laboratory that 10(exp -4) M H2O2 has little effect on the absorption spectrum of the dye IR125 over a period of hours but that the band at 780 nm is slowly lost in water over a period of days even under argon in the dark. By contrast, DMSO solutions of IR125 are stable.
Fluorometric determination of histamine in cheese.
Chambers, T L; Staruszkiewicz, W F
1978-09-01
Thirty-one samples of cheese obtained from retail outlets were analyzed for histamine, using an official AOAC fluorometric method. The types of cheese analyzed and the ranges of histamine found were: colby, 0.3--2.8; camembert, 0.4--4.2; cheddar, 1.2--5.8; gouda, 1.3--2.4; provolone, 2.0--23.5; roquefort, 1.0--16.8; mozzarella 1.6--5.0; and swiss, 0.4--250 mg histamine/100 g. Ten of the 12 samples of swiss cheese contained less than 16 mg histamine/100 g. The remaining 2 samples which contained 116 and 250 mg histamine/100 g were judged organoleptically to be of poor quality. An investigation of one processing facility showed that the production of histamine in swiss cheese may have been a result of a hydrogen peroxide/low temperature treatment of the milk supply. Recovery of histamine added to methanol extracts of cheese ranged from 93 to 105%. Histamine content was confirmed by high pressure liquid chromatographic analysis of the methanol extracts.
Fluorometric determination of zirconium in minerals
Alford, W.C.; Shapiro, L.; White, C.E.
1951-01-01
The increasing use of zirconium in alloys and in the ceramics industry has created renewed interest in methods for its determination. It is a common constituent of many minerals, but is usually present in very small amounts. Published methods tend to be tedious, time-consuming, and uncertain as to accuracy. A new fluorometric procedure, which overcomes these objections to a large extent, is based on the blue fluorescence given by zirconium and flavonol in sulfuric acid solution. Hafnium is the only element that interferes. The sample is fused with borax glass and sodium carbonate and extracted with water. The residue is dissolved in sulfuric acid, made alkaline with sodium hydroxide to separate aluminum, and filtered. The precipitate is dissolved in sulfuric acid and electrolysed in a Melaven cell to remove iron. Flavonol is then added and the fluorescence intensity is measured with a photo-fluorometer. Analysis of seven standard mineral samples shows excellent results. The method is especially useful for minerals containing less than 0.25% zirconium oxide.
Fluorometric Index for Sensing Oil in the Sea Environment.
Baszanowska, Emilia; Otremba, Zbigniew
2017-06-02
Excitation-emission matrix spectroscopy (EEMS) was applied to determine the fluorometric index (FI) as a parameter indicating the presence of a source of oil pollution in a specific area of the sea. Seawater from the Polish coast (the Baltic Sea) and the same water combined with various amounts of crude oil extracted from the Baltic Sea shelf ( Petrobaltic -type oil) were used in this study. The FI values were calculated for excitation and emission wavelengths found at the maximal peak, taking into account the natural seawater and the seawater artificially contaminated (for an oil-to-water ratio range of 0.5 × 10 -6 - 500 × 10 -6 ). The wavelength configurations (Ex/Em) (225/355 and 225/340) for the FI index were applied. It was found that, independent of the amount of oil, the FI achieves a higher value for natural seawater than for seawater that has had contact with oil. These results provide the basis to design a sensor signaling the appearance of oil in a defined sea area.
Anderson, George P; Glaven, Richard H; Algar, W Russ; Susumu, Kimihiro; Stewart, Michael H; Medintz, Igor L; Goldman, Ellen R
2013-07-05
The combination of stable biorecognition elements and robust quantum dots (QDs) has the potential to yield highly effective reporters for bioanalyses. Llama-derived single domain antibodies (sdAb) provide small thermostable recognition elements that can be easily manipulated using standard DNA methods. The sdAb was self-assembled on dihydrolipoic acid (DHLA) ligand-capped CdSe-ZnS core-shell QDs made in our laboratory through the polyhistidine tail of the protein, which coordinated to zinc ions on the QD surface. The sdAb-QD bioconjugates were then applied in both fluorometric and surface plasmon resonance (SPR) immunoassays for the detection of ricin, a potential biothreat agent. The sdAb-QD conjugates functioned in fluoroimmunoassays for the detection of ricin, providing equivalent limits of detection when compared to the same anti-ricin sdAb labeled with a conventional fluorophore. In addition, the DHLA-QD-sdAb conjugates were very effective reporter elements in SPR sandwich assays, providing more sensitive detection with a signal enhancement of ~10-fold over sdAb reporters and 2-4 fold over full sized antibody reporters. Commercially prepared streptavidin-modified polymer-coated QDs also amplified the SPR signal for the detection of ricin when applied to locations where biotinylated anti-ricin sdAb was bound to target; however, we observed a 4-fold greater amplification when using the DHLA-QD-sdAb conjugates in this format. Copyright © 2013. Published by Elsevier B.V.
An enzymatic fluorescent assay for the quantification of phosphite in a microtiter plate format.
Berkowitz, Oliver; Jost, Ricarda; Pearse, Stuart J; Lambers, Hans; Finnegan, Patrick M; Hardy, Giles E St J; O'Brien, Philip A
2011-05-01
A sensitive fluorometric assay for the quantification of phosphite has been developed. The assay uses the enzymatic oxidation of phosphite to phosphate by a recombinant phosphite dehydrogenase with NAD(+) as cosubstrate to produce the highly fluorescent reaction product resorufin. The optimized assay can be carried out in a 96-well microtiter plate format for high-throughput screening purposes and has a detection limit of 0.25 nmol phosphite. We used the method to quantify phosphite levels in plant tissue extracts and to determine phosphite dehydrogenase activity in transgenic plants. The assay is suitable for other biological or environmental samples. Because phosphite is a widely used fungicide to protect plants from pathogenic oomycetes, the assay provides a cost-effective and easy-to-use method to monitor the fate of phosphite following application. Copyright © 2011 Elsevier Inc. All rights reserved.
Sakamoto, Misato; Shoji, Atsushi; Sugawara, Masao
2016-07-15
Functionalized giant unilamellar vesicles (GUVs) containing a fluorescence dye Rhodamine 6G is proposed as a marker in sandwich-type immunoassay for bovine serum albumin (BSA) and lipocalin-2 (LCN2). The GUVs were prepared by the electroformation method and functionalized with anti-BSA antibody and anti-LCN2 antibody, respectively. The purification of antibody-modified GUVs was achieved by conventional centrifugation and a washing step in a flow system. To antigen on an antibody slip, antibody-modified GUVs were added as a marker and incubated. After wash-out of excess reagents and lysis of the bound GUVs with Triton X-100, the fluorescence image was captured. The fluorometric immunoassays for BSA and LCN2 exhibited lower detection limits of 4 and 80 fg ml(-)(1), respectively. Copyright © 2016 Elsevier Inc. All rights reserved.
Nagatoishi, Satoru; Nojima, Takahiko; Galezowska, Elzbieta; Juskowiak, Bernard; Takenaka, Shigeori
2006-11-01
The dual-labeled oligonucleotide derivative, FAT-0, carrying 6- carboxyfluorescein (FAM) and 6-carboxytetramethylrhodamine (TAMRA) labels at the 5' and 3' termini of the thrombin-binding aptamer (TBA) sequence 5'-GGT TGG TGT GGT TGG-3', and its derivatives, FAT-n (n=3, 5, and 7) with a spacer at the 5'-end of a TBA sequence of T(m)A (m=2, 4, and 6) have been designed and synthesized. These fluorescent probes were developed for monitoring K(+) concentrations in living organisms. Circular dichroism, UV-visible absorption, and fluorescence studies revealed that all FAT-n probes could form intramolecular tetraplex structures after binding K(+). Fluorescence resonance energy transfer and quenching results are discussed taking into account dye-dye contact interactions. The relationship between the fluorescence behavior of the probes and the spacer length in FAT-n was studied in detail and is discussed.
Determination of Time since Death using Vitreous Humor Tryptophan.
Ansari, Niha; Menon, Shobhana K
2017-09-01
Determination of time since death (TSD) plays very important role in forensic examination as it narrows down field of suspects and aids in deceased identification. This study utilizes the fluorescence property of vitreous humor (VH) tryptophan to determine TSD using o-phthalaldehyde (OPA). The detection limit of these fluorometric studies was found to be 8 ppb indicating sensitivity and high accuracy in TSD determination. The study was performed on selected 76 cadaver with known TSD ranging from 3 to 90 h. Excellent correlation between VH tryptophan and TSD was obtained with a coefficient of correlation R 2 = 0.9590. Results showed statistically significant increase in vitreous tryptophan with TSD up to 90 h, and the proposed method was efficaciously applied for prediction of TSD as no systematic error exist. The regression equation obtained from the study is [Trp] = 2.21 + 2.98 * TSD. © 2017 American Academy of Forensic Sciences.
Repellents Inhibit P450 Enzymes in Stegomyia (Aedes) aegypti
Jaramillo Ramirez, Gloria Isabel; Logan, James G.; Loza-Reyes, Elisa; Stashenko, Elena; Moores, Graham D.
2012-01-01
The primary defence against mosquitoes and other disease vectors is often the application of a repellent. Despite their common use, the mechanism(s) underlying the activity of repellents is not fully understood, with even the mode of action of DEET having been reported to be via different mechanisms; e.g. interference with olfactory receptor neurones or actively detected by olfactory receptor neurones on the antennae or maxillary palps. In this study, we discuss a novel mechanism for repellence, one of P450 inhibition. Thirteen essential oil extracts from Colombian plants were assayed for potency as P450 inhibitors, using a kinetic fluorometric assay, and for repellency using a modified World Health Organisation Pesticide Evaluations Scheme (WHOPES) arm-in cage assay with Stegomyia (Aedes) aegypti mosquitoes. Bootstrap analysis on the inhibition analysis revealed a significant correlation between P450-inhibition and repellent activity of the oils. PMID:23152795
Integrating Biology into the General Chemistry Laboratory: Fluorometric Analysis of Chlorophyll "a"
ERIC Educational Resources Information Center
Wesolowski, Meredith C.
2014-01-01
A laboratory experiment that introduces fluorometry of chlorophyll "a" at the general chemistry level is described. The use of thin-layer chromatography to isolate chlorophyll "a" from spirulina and leaf matter enables quantification of small amounts of chlorophyll "a" via fluorometry. Student results were reasonably…
The perspectives, information and conclusions conveyed in research project abstracts, progress reports, final reports, journal abstracts and journal publications convey the viewpoints of the principal investigator and may not represent the views and policies of ORD and EPA. Concl...
Swallowable fluorometric capsule for wireless triage of gastrointestinal bleeding.
Nemiroski, A; Ryou, M; Thompson, C C; Westervelt, R M
2015-12-07
Real-time detection of gastrointestinal bleeding remains a major challenge because there does not yet exist a minimally invasive technology that can both i) monitor for blood from an active hemorrhage and ii) uniquely distinguish it from blood left over from an inactive hemorrhage. Such a device would be an important tool for clinical triage. One promising solution, which we have proposed previously, is to inject a fluorescent dye into the blood stream and to use it as a distinctive marker of active bleeding by monitoring leakage into the gastrointestinal tract with a wireless fluorometer. This paper reports, for the first time to our knowledge, the development of a swallowable, wireless capsule with a built-in fluorometer capable of detecting fluorescein in blood, and intended for monitoring gastrointestinal bleeding in the stomach. The embedded, compact fluorometer uses pinholes to define a microliter sensing volume and to eliminate bulky optical components. The proof-of-concept capsule integrates optics, low-noise analog sensing electronics, a microcontroller, battery, and low power Zigbee radio, all into a cylindrical package measuring 11 mm × 27 mm and weighing 10 g. Bench-top experiments demonstrate wireless fluorometry with a limit-of-detection of 20 nM aqueous fluorescein. This device represents a major step towards a technology that would enable simple, rapid detection of active gastrointestinal bleeding, a capability that would save precious time and resources and, ultimately, reduce complications in patients.
Yun, Kyusik; Zhong, Linlin
2018-05-16
A novel fluorescence "Switch on" for the detection of heparin based on the RhB-COL/GO system was achieved. A strong fluorescence dye, Rhodamine B, was modified by chitosan oligosaccharide lactate (COL), which plays a major role in the formation of a positively charged RhB-COL complex. RhB-COL was soluble and stable in solution, which was characterized by using Fourier transform infrared spectroscopy and X-ray photoelectron spectroscopy. GO sheets quenched the fluorescence intensity of RhB-COL due to electron transfer from RhB to the GO surface. The decrease in fluorescence intensity of RhB-COL with increasing GO concentration was recorded using a Cary Eclipse fluorescence spectrophotometer. On the other hand, the addition of heparin replaced GO to bind with the RhB-COL surface via an electrostatic and noncovalent bond due to the abundant negative charge, which resulted in recovery of the fluorescence intensity. This RhB-COL/GO system possessed high selectivity and good sensitivity for the detection of heparin compared to other biomolecules, such as glycine, D-glucose, hyaluronic acid, L-glutamic acid, and ascorbic acid. The linear response toward heparin was measured over the range, 0-1.8 U·mL-1, with a low detection limit of 0.04 U·mL-1. The satisfactory sensing performance of RhB-COL/GO for heparin supports new "switch-on" sensor applications in heparin-related biomedical detection. © 2018 IOP Publishing Ltd.
NASA Astrophysics Data System (ADS)
Zhong, Linlin; Yun, Kyusik
2018-07-01
A novel fluorescence ‘Switch on’ for the detection of heparin based on the RhB-COL/GO system was achieved. A strong fluorescence dye, Rhodamine B, was modified by chitosan oligosaccharide lactate (COL), which plays a major role in the formation of a positively charged RhB-COL complex. RhB-COL was soluble and stable in solution, which was characterized by using Fourier transform infrared spectroscopy and x-ray photoelectron spectroscopy. GO sheets quenched the fluorescence intensity of RhB-COL due to electron transfer from RhB to the GO surface. The decrease in fluorescence intensity of RhB-COL with increasing GO concentration was recorded using a Cary Eclipse fluorescence spectrophotometer. On the other hand, the addition of heparin replaced GO to bind with the RhB-COL surface via an electrostatic and noncovalent bond due to the abundant negative charge, which resulted in recovery of the fluorescence intensity. This RhB-COL/GO system possessed high selectivity and good sensitivity for the detection of heparin compared to other biomolecules, such as glycine, D-glucose, hyaluronic acid, L-glutamic acid, and ascorbic acid. The linear response toward heparin was measured over the range, 0–1.8 U · ml‑1, with a low detection limit of 0.04 U · ml‑1. The satisfactory sensing performance of RhB-COL/GO for heparin supports new ‘switch-on’ sensor applications in heparin-related biomedical detection.
A synchronous fluorescent spectroscopy (SFS) method was developed to measure pyrene-type metabolites in the bile of brown bullhead (Ameiurus nebulosus) and to estimate the exposure of fish to PAHs in four Lake Erie tributaries collected in the spring and fall of 1990 and 1991. Fo...
The perspectives, information and conclusions conveyed in research project abstracts, progress reports, final reports, journal abstracts and journal publications convey the viewpoints of the principal investigator and may not represent the views and policies of ORD and EPA. Concl...
NASA Astrophysics Data System (ADS)
Ibrahim, M. M.
2017-04-01
Doping of mesoporous ZnO-ZrO2 nanoparticles with transition metal and lanthanides (Cr, Nd, Dy) were used as a catalyst to develop an ultrasensitive fluorometric method for the conversion of non fluorescent coumarin to highly fluorescent 7-hydroxycoumarin using H2O2 or light. It was found that doped- ZnO-ZrO2 mixed oxide can catalyze the decomposition of H2O2 to produce •OH radicals, which in turn convert coumarin to 7-hydroxycoumarin. At contrast, the doping has deleterious effect on conversion of coumarin by light due to high band gap and high concentrations of doping increase the recombination rate of electron and holes. Doped mixed oxides prepared by impregnation method and characterized by studying their structural, surface and optical properties. Chromium doped ZnO-ZrO2 had the highest rate of formation of hydroxyl radical due to decomposition of H2O2 and therefore 7-hydroxycoumarin due to surface area, small crystal size and high redox potential.
A fluorometric determination of urinary 17-hydroxycorticosteroids using benzamidine.
Yamaguchi, Y; Seki, T
1984-10-01
A fluorometric determination of urinary 17-hydroxycorticosteroids using a reaction of benzamidine with compounds carrying the dihydroxyacetone side chain is described. The fluorescent compounds have excitation and emission maxima at 370 and 480 nm, respectively. The method includes enzymatic hydrolysis with beta-glucuronidase (EC 3.2.1.31, from Escherichia coli) and extraction with methylene chloride and generation of fluorescence in alkaline solution (pH 13.4). The specificity of the reaction was examined and the results were compared with those of an accepted method based on the Porter-Silber reaction (C. C. Porter and R. H. Silber, 1950, J. Biol. Chem. 185, 201-207). The coefficient of correlation was 0.945 with regression line of y = 0.91x + 0.7 mg/day (y, present method; x, Porter-Silber reaction method). Sensitivity of the reaction was 0.5 microgram/ml of standard or sample, mean recovery of cortisol added to five urine samples (5-micrograms addition) was 95%, and the coefficient of variation of the method (five repeated assays of sample with a value of 5.2 mg/liter) was 6.2%.
NASA Astrophysics Data System (ADS)
Rui, Qing-Qing; Zhou, Yi; Fang, Yuan; Yao, Cheng
2016-04-01
Two new rhodamine B-based fluorescent probes PyRbS and PyRbO containing pyrene moiety were designed and synthesized. Both of the probes showed colorimetric and fluorometric sensing abilities for Hg2 + with high selectivity over other metal ions. The binding analysis using Job's plot suggested 1:1 stoichiometry for the complexes formed for Hg2 +. Compared with PyRbO, the PyRbS showed higher selectivity and sensitivity due to the thiophilic property of Hg2 + ion. The PyRbS exhibited the linear fluorescence quenching to Hg2 + in the range of 0.3 to 4.8 μM (λex = 365 nm) and 0.3 to 5.4 μM (λex = 515 nm), and the detection limit was 0.72 μM. Moreover, ratiometric changes of PyRbS with Hg2 + in absorption spectrum were observed, which could not be obtained in the combination of PyRbO with Hg2 +. In addition, the methyl thiazolyl tetrazolium (MTT) assay demonstrated that RbPyS had low cytotoxicity and was successfully used to monitor intracellular Hg2 + levels in living cells.
2003-05-01
retinoids, deltanoids (vitamin D derivatives), phytoestrogens, flavonoids , and aromatase inhibitors among others (Kelloffet al, 1996). On a global basis...Dietetics, University of Illinois at Chicago, Chicago. Responsibilities included development and validation of MDA-TBA assay by HPLC with fluorometric
Jothikumar, Prithiviraj; Narayanan, Jothikumar; Hill, Vincent R
2014-03-01
Rapid and specific detection methods for bacterial agents in drinking water are important for disease prevention and responding to suspected contamination events. In this study, an isothermal Genome Exponential Amplification Reaction (GEAR) assay for Escherichia coli O157:H7 was designed specifically to recognize a 199-bp fragment of the lipopolysaccharide gene (rfbE) for rapid testing of water samples. The GEAR assay was found to be specific for E. coli O157:H7 using 10 isolates of E. coli O157:H7 and a panel of 86 bacterial controls. The GEAR assay was performed at a constant temperature of 65°C using SYTO 9 intercalating dye. Detection limits were determined to be 20 CFU for the GEAR assay. When SYTO 9 fluorescence was measured using a real-time PCR instrument, the assay had the same detection limit as when malachite green was added to the reaction mix and a characteristic blue color was visually observed in positive reactions. The study also found that 50 and 20 CFU of E. coli O157:H7 seeded into 100-liter of tap water could be detected by the GEAR assays after the sample was concentrated by hollow-fiber ultrafiltration (HFUF) and approximately 10% of HFUF concentrate was cultured using trypticase soy broth-novobiocin. When applied to 19 surface water samples collected from Tennessee and Kentucky, the GEAR assay and a published real-time PCR assay both detected E. coli O157:H7 in two of the samples. The results of this study indicate that the GEAR assay can be sensitive for rapid detection of E. coli O157:H7 in water samples using fluorometric instruments and visual endpoint determination. Published by Elsevier B.V.
Phytoplankton-Fluorescence-Lifetime Vertical Profiler
NASA Technical Reports Server (NTRS)
Fernandez, Salvador M.; Guignon, Ernest F.; St. Louis, Ernest
2004-01-01
A battery-operated optoelectronic instrument is designed to be lowered into the ocean to measure the intensity and lifetime of fluorescence of chlorophyll A in marine phytoplankton as a function of depth from 0 to 300 m. Fluorescence lifetimes are especially useful as robust measures of photosynthetic productivity of phytoplankton and of physical and chemical mechanisms that affect photosynthesis. The knowledge of photosynthesis in phytoplankton gained by use of this and related instruments is expected to contribute to understanding of global processes that control the time-varying fluxes of carbon and associated biogenic elements in the ocean. The concentration of chlorophyll in the ocean presents a major detection challenge because in order to obtain accurate values of photosynthetic parameters, the intensity of light used to excite fluorescence must be kept very low so as not to disturb the photosynthetic system. Several innovations in fluorometric instrumentation were made in order to make it possible to reach the required low detection limit. These innovations include a highly efficient optical assembly with an integrated flow-through sample interface, and a high-gain, low-noise electronic detection subsystem. The instrument also incorporates means for self-calibration during operation, and electronic hardware and software for control, acquisition and analysis of data, and communications. The electronic circuitry is highly miniaturized and designed to minimize power demand. The instrument is housed in a package that can withstand the water pressure at the maximum depth of 300 m. A light-emitting diode excites fluorescence in the sample flow cell, which is placed at one focal point of an ellipsoidal reflector. A photomultiplier tube is placed at the other focal point. This optical arrangement enables highly efficient collection of fluorescence emitted over all polar directions. Fluorescence lifetime is measured indirectly, by use of a technique based on the same principle as the one described in "Fluorometer for Analysis of Photosynthesis in Phytoplankton" (SSC-00110), NASA Tech Briefs, Vol. 24, No. 1 (November 2000), page 79. The excitation is modulated at a frequency of 70 MHz, and the phase shift between the excitation light and the emitted fluorescence is measured by a detection method in which the 70 MHz signal is down-converted to a 400 Hz signal. The fluorescence lifetime can be computed from the known relationship among the fluorescence lifetime, phase shift, and modulation frequency
Glowing locked nucleic acids: brightly fluorescent probes for detection of nucleic acids in cells.
Østergaard, Michael E; Cheguru, Pallavi; Papasani, Madhusudhan R; Hill, Rodney A; Hrdlicka, Patrick J
2010-10-13
Fluorophore-modified oligonucleotides have found widespread use in genomics and enable detection of single-nucleotide polymorphisms, real-time monitoring of PCR, and imaging of mRNA in living cells. Hybridization probes modified with polarity-sensitive fluorophores and molecular beacons (MBs) are among the most popular approaches to produce hybridization-induced increases in fluorescence intensity for nucleic acid detection. In the present study, we demonstrate that the 2'-N-(pyren-1-yl)carbonyl-2'-amino locked nucleic acid (LNA) monomer X is a highly versatile building block for generation of efficient hybridization probes and quencher-free MBs. The hybridization and fluorescence properties of these Glowing LNA probes are efficiently modulated and optimized by changes in probe backbone chemistry and architecture. Correctly designed probes are shown to exhibit (a) high affinity toward RNA targets, (b) excellent mismatch discrimination, (c) high biostability, and (d) pronounced hybridization-induced increases in fluorescence intensity leading to formation of brightly fluorescent duplexes with unprecedented emission quantum yields (Φ(F) = 0.45-0.89) among pyrene-labeled oligonucleotides. Finally, specific binding between messenger RNA and multilabeled quencher-free MBs based on Glowing LNA monomers is demonstrated (a) using in vitro transcription assays and (b) by quantitative fluorometric assays and direct microscopic observation of probes bound to mRNA in its native form. These features render Glowing LNA as promising diagnostic probes for biomedical applications.
Shoulkamy, Mahmoud I.; Nakano, Toshiaki; Ohshima, Makiko; Hirayama, Ryoichi; Uzawa, Akiko; Furusawa, Yoshiya; Ide, Hiroshi
2012-01-01
Proteins are covalently trapped on DNA to form DNA–protein crosslinks (DPCs) when cells are exposed to DNA-damaging agents. DPCs interfere with many aspects of DNA transactions. The current DPC detection methods indirectly measure crosslinked proteins (CLPs) through DNA tethered to proteins. However, a major drawback of such methods is the non-linear relationship between the amounts of DNA and CLPs, which makes quantitative data interpretation difficult. Here we developed novel methods of DPC detection based on direct CLP measurement, whereby CLPs in DNA isolated from cells are labeled with fluorescein isothiocyanate (FITC) and quantified by fluorometry or western blotting using anti-FITC antibodies. Both formats successfully monitored the induction and elimination of DPCs in cultured cells exposed to aldehydes and mouse tumors exposed to ionizing radiation (carbon-ion beams). The fluorometric and western blotting formats require 30 and 0.3 μg of DNA, respectively. Analyses of the isolated genomic DPCs revealed that both aldehydes and ionizing radiation produce two types of DPC with distinct stabilities. The stable components of aldehyde-induced DPCs have half-lives of up to days. Interestingly, that of radiation-induced DPCs has an infinite half-life, suggesting that the stable DPC component exerts a profound effect on DNA transactions over many cell cycles. PMID:22730301
Optrode for sensing hydrocarbons
Miller, Holly; Milanovich, Fred P.; Hirschfeld, Tomas B.; Miller, Fred S.
1987-01-01
A two-phase system employing the Fujiwara reaction is provided for the fluorometric detection of halogenated hydrocarbons. A fiber optic is utilized to illuminate a column of pyridine trapped in a capillary tube coaxially attached at one end to the illuminating end of the fiber optic. A strongly alkaline condition necessary for the reaction is maintained by providing a reservoir of alkali in contact with the column of pyridine, the surface of contact being adjacent to the illuminating end of the fiber optic. A semipermeable membrane caps the other end of the capillary tube, the membrane being preferentially permeable to the halogenated hydrocarbon and but preferentially impermeable to water and pyridine. As the halogenated hydrocarbon diffuses through the membrane and into the column of pyridine, fluorescent reaction products are formed. Light propagated by the fiber optic from a light source, excites the fluorescent products. Light from the fluorescence emission is also collected by the same fiber optic and transmitted to a detector. The intensity of the fluorescence gives a measure of the concentration of the halogenated hydrocarbons.
Optrode for sensing hydrocarbons
Miller, H.; Milanovich, F.P.; Hirschfeld, T.B.; Miller, F.S.
1987-05-19
A two-phase system employing the Fujiwara reaction is provided for the fluorometric detection of halogenated hydrocarbons. A fiber optic is utilized to illuminate a column of pyridine trapped in a capillary tube coaxially attached at one end to the illuminating end of the fiber optic. A strongly alkaline condition necessary for the reaction is maintained by providing a reservoir of alkali in contact with the column of pyridine, the surface of contact being adjacent to the illuminating end of the fiber optic. A semipermeable membrane caps the other end of the capillary tube, the membrane being preferentially permeable to the halogenated hydrocarbon but preferentially impermeable to water and pyridine. As the halogenated hydrocarbon diffuses through the membrane and into the column of pyridine, fluorescent reaction products are formed. Light propagated by the fiber optic from a light source, excites the fluorescent products. Light from the fluorescence emission is also collected by the same fiber optic and transmitted to a detector. The intensity of the fluorescence gives a measure of the concentration of the halogenated hydrocarbons. 6 figs.
Optrode for sensing hydrocarbons
Miller, H.; Milanovich, F.P.; Hirschfeld, T.B.; Miller, F.S.
1988-09-13
A two-phase system employing the Fujiwara reaction is provided for the fluorometric detection of halogenated hydrocarbons. A fiber optic is utilized to illuminate a column of pyridine trapped in a capillary tube coaxially attached at one end to the illuminating end of the fiber optic. A strongly alkaline condition necessary for the reaction is maintained by providing a reservoir of alkali in contact with the column of pyridine, the surface of contact being adjacent to the illuminating end of the fiber optic. A semipermeable membrane caps the other end of the capillary tube, the membrane being preferentially permeable to the halogenated hydrocarbon and but preferentially impermeable to water and pyridine. As the halogenated hydrocarbon diffuses through the membrane and into the column of pyridine, fluorescent reaction products are formed. Light propagated by the fiber optic from a light source, excites the fluorescent products. Light from the fluorescence emission is also collected by the same fiber optic and transmitted to a detector. The intensity of the fluorescence gives a measure of the concentration of the halogenated hydrocarbons. 5 figs.
Optrode for sensing hydrocarbons
Miller, Holly; Milanovich, Fred P.; Hirschfeld, Tomas B.; Miller, Fred S.
1988-01-01
A two-phase system employing the Fujiwara reaction is provided for the fluorometric detection of halogenated hydrocarbons. A fiber optic is utilized to illuminate a column of pyridine trapped in a capillary tube coaxially attached at one end to the illuminating end of the fiber optic. A strongly alkaline condition necessary for the reaction is maintained by providing a reservoir of alkali in contact with the column of pyridine, the surface of contact being adjacent to the illuminating end of the fiber optic. A semipermeable membrane caps the other end of the capillary tube, the membrane being preferentially permeable to the halogenated hydrocarbon and but preferentially impermeable to water and pyridine. As the halogenated hydrocarbon diffuses through the membrane and into the column of pyridine, fluorescent reaction products are formed. Light propagated by the fiber optic from a light source, excites the fluorescent products. Light from the fluorescence emission is also collected by the same fiber optic and transmitted to a detector. The intensity of the fluorescence gives a measure of the concentration of the halogenated hydrocarbons.
Hsieh, Hua-Yi; Li, Li-Hua; Hsu, Ren-Yu; Kao, Wei-Fong; Huang, Ying-Chen; Hsu, Cheng-Chih
2017-06-06
Blood testing for endogenous small metabolites to determine physiological and biochemical states is routine for laboratory analysis. Here we demonstrate that by combining the commercial direct analysis in real time (DART) ion source with an ion trap mass spectrometer, native cholesterol in its free alcohol form is readily detected from a few hundred nanoliters of human serum loaded onto chromatography paper. Deuterium-labeled cholesterol was used as the internal standard to obtain the absolute quantity of the endogenous cholesterol. The amount of the cholesterol measured by this paper-loaded DART mass spectrometry (pDART-MS) is statistically comparable with that obtained by using commercially available fluorometric-enzymatic assay and liquid chromatography/mass spectrometry. Furthermore, sera from 21 participants at three different time points in an ultramarathon were collected to obtain their cholesterol levels. The test requires only very minimal sample preparation, and the concentrations of cholesterol in each sample were acquired within a minute.
Papoti, Vassiliki T; Tsimidou, Maria Z
2009-05-13
The impact of sampling parameters, that is, cultivar, leaf age, and sampling date, on the radical scavenging potential of olive leaf extracts was examined via the DPPH(*) and other assays. Total phenol content was estimated colorimetrically and by fluorometry, whereas phenol composition was assessed by RP-HPLC coupled with diode array, fluorometric, and MS detection systems. Oleuropein was not always the major leaf constituent. Considerable differences noted in individual phenol levels (hydroxytyrosol, oleuropein and other secoiridoids, verbascoside, and flavonoids) among samples were not reflected either in the total phenol content or in the radical scavenging potential of the extracts. It can be suggested that olive leaf is a robust source of radical scavengers throughout the year and that differentiation in the levels of individual components depends rather on sampling period than on cultivar or age. The latter does not present predictable regularity. Exploitation of all types of leaves expected in an olive tree shoot for the extraction of bioactive compounds is feasible.
Artemisinin induces ROS-mediated caspase3 activation in ASTC-a-1 cells
NASA Astrophysics Data System (ADS)
Xiao, Feng-Lian; Chen, Tong-Sheng; Qu, Jun-Le; Liu, Cheng-Yi
2010-02-01
Artemisinin (ART), an antimalarial phytochemical from the sweet wormwood plant or a naturally occurring component of Artemisia annua, has been shown a potential anticancer activity by apoptotic pathways. In our report, cell counting kit (CCK-8) assay showed that treatment of human lung adenocarcinoma (ASTC-a-1) cells with ART effectively increase cell death by inducing apoptosis in a time- and dose-dependent fashion. Hoechst 33258 staining was used to detect apoptosis as well. Reactive oxygen species (ROS) generation was observed in cells exposed to ART at concentrations of 400 μM for 48 h. N-acetyl-L-cysteine (NAC), an oxygen radical scavenger, suppressed the rate of ROS generation and inhibited the ART-induced apoptosis. Moreover, AFC assay (Fluorometric assay for Caspase3 activity) showed that ROS was involved in ART-induced caspase3 acitvation. Taken together, our data indicate that ART induces ROS-mediated caspase3 activation in a time-and dose-dependent way in ASCT-a-1 cells.
Substrates and method for determining enzymes
Smith, Robert E.; Bissell, Eugene R.
1981-01-01
A method is disclosed for determining the presence of an enzyme in a biological fluid, which includes the steps of contacting the fluid with a synthetic chromogenic substrate, which is an amino acid derivative of 7-amino-4-trifluoromethylcoumarin; incubating the substrate-containing fluid to effect enzymatic hydrolysis; and fluorometrically determining the presence of the free 7-amino-4-trifluoromethylcoumarin chromophore in the hydrolyzate.
Premsagar Korripally; Christopher G. Hunt; Carl J. Houtman; Don C. Jones; Peter J. Kitin; Dan Cullen; Kenneth E. Hammel; A. A. Brakhage
2015-01-01
Since uncertainty remains about how white rot fungi oxidize and degrade lignin in wood, it would be useful to monitor changes in fungal gene expression during the onset of ligninolysis on a natural substrate. We grew Phanerochaete chrysosporium on solid spruce wood and included oxidant-sensing beads bearing the fluorometric dye BODIPY 581/591 in...
Elbin, Carole S; Olivova, Petra; Marashio, Carla A; Cooper, Samantha K; Cullen, Emmaline; Keutzer, Joan M; Zhang, X Kate
2011-06-11
Fluorometric and tandem mass spectrometry assays can be used to measure lysosomal enzyme activities in dried blood spots (DBS). The effect of DBS preparation, storage and shipping was evaluated on the activities of acid α-glucosidase, acid α-galactosidase, acid β-glucocerebrosidase, acid sphingomyelinase, and galactocerebrosidase. Whole blood from normal donors was used to prepare DBS following Clinical and Laboratory Standards Institute guidelines and by several deviations. Some DBS were subjected to various treatments, storage and shipping conditions. The activity of 5 lysosomal enzymes (GAA, GLA, GBA, ASM, and GALC) was measured using tandem mass spectrometric and fluorometric (GAA only) assays with 2 distinct and commonly used synthetic substrates. Enzyme activities were strongly affected by the way DBS were prepared and stored. Exposure of DBS to elevated heat and humidity can destroy enzyme functions rapidly. DBS prepared from poorly mixed blood caused significant variation on enzyme activities. EDTA, but not heparin, as an anti-coagulant gave more precise results. The study confirmed the importance of proper and consistent DBS preparation and storage when screening for deficiencies of lysosomal enzymes. Copyright © 2011 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Karimi, A.R.
In this study a method for the measurement of uranium in natural waters at sub-ppB concentration levels by the separation and determination of U/sup 4 +/ and UO/sub 2//sup 2 +/ species is proposed. Reversed phase high performance liquid chromatography, followed by a post-column reaction and a sensitive UV-visible detection system was the method of choice to determine qualitatively and quantitatively the two uranium species. Also a cation-exchange and fluorescence detection system was studied for separation and determination of UO/sub 2//sup 2 +/ ions. Uranyl ion was selectively complexed with L-phenylalanine moetie in the sample solution containing U/sup 4 +/more » ions. Uranium (IV)/U(VI)-ligand was separated on a C/sub 18/ column with acetate buffer. Hexanesulfonate was found to be the choice for ion-pair reagent. The separation was best done with the acetate buffer at .01 M concentration and pH of 3.5. Absorption of the two species were measured after a post-column reaction with Arsenazo-III. Chromatographic parameters were calculated and a calibration curves were constructed. The detection limit for the procedure was 0.7 ..mu..g/mo and 1.2..mu..g/ml for U(IV) and U(VI) respectively. When U(VI) was separated on the cation-exchange column the limit of detection was calculated to be 1 ..mu..g/ml. The direct fluorometric method for U(VI) measurement results in a detection limit of 2 ppB and upper concentration limit of 2 ppM. The effect of interfering ions in the direct method of determination could be eliminated by dilution of sample solution.« less
NASA Astrophysics Data System (ADS)
Xing, Xiaogang; Morel, André; Claustre, Hervé; D'Ortenzio, Fabrizio; Poteau, Antoine
2012-04-01
Eight autonomous profiling "Bio-Argo" floats were deployed offshore during about 2 years (2008-2010) in Pacific, Atlantic, and Mediterranean zones. They were equipped with miniaturized bio-optical sensors, namely a radiometer measuring within the upper layer the downward irradiance at 412, 490, and 555 nm, and two fluorometers for detection of chlorophyll-a (Chla) and colored dissolved organic matter (CDOM; profiles from 400 m to surface). A first study dealt with the interpretation of the Chla fluorescence signal in terms of concentration, using for this purpose the diffuse attenuation coefficient for irradiance at 490 nm, Kd(490), taken as a proxy for the Chla absorption. The present study examines the possibility of similarly using the Kd(412) values combined with retrieved Chla profiles to convert the CDOM fluorometric qualitative information into a CDOM absorption coefficient (ay). The rationale is to take advantage of the fact that Kd is more sensitive to CDOM presence at 412 nm than at 490 nm. A validation of this method is tested through its application to field data, collected from a ship over a wide range of trophic conditions (Biogeochemistry and Optics South Pacific Experiment (BIOSOPE) cruise); these data include both in situ fluorescence profiles and CDOM absorption as measured on discrete samples. In addition, near-surface ay values retrieved from the floats agree with those derivable from ocean color imagery (Moderate Resolution Imaging Spectroradiometer (MODIS-A)). The low sensitivity of commercially available CDOM fluorometers presently raises difficulties when applying this technique to open ocean waters. It was nevertheless possible to derive from the floats records meaningful time series of CDOM vertical distribution.
Singh, Jaswant; Parkash, Jyoti; Kaur, Varinder; Singh, Raghubir
2017-10-05
A new method is reported for the quantification of some metallic components of healthcare products utilizing a Schiff base chelator derived from 2-hydroxyacetophenone and ethanolamine. The Schiff base chelator recognizes some metallic species such as iron, copper and zinc (important components of some healthcare products), and cadmium (common contaminant in healthcare products) giving colorimetric/fluorimetric response. It coordinates with Fe 2+ /Fe 3+ and Cu 2+ ions via ONO donor set and switches the colour to bright red, green and orange, respectively. Similarly, it switches 'ON' a fluorometric response when coordinates with Zn 2+ and Cd 2+ ions. In the present approach, detailed studies on the colorimetric and fluorimetric response of ONO Schiff base is investigated in detail. The Job plot for the complexation of ONO switch with various metal ions suggested formation of 1:1 (metal-chelator) complex with Fe 2+ , Fe 3+ , and Cu 2+ while 1:2 (metal-chelator) for Zn 2+ and Cd 2+ ions. The limit of detection, limit of quantification are 6.73, 18.0, 25.0, 0.65, 1.10μM and 27.0, 72.0, 100.0, 2.60 and 4.40μM for Fe 2+ , Fe 3+ , Cu 2+ , Zn 2+ and Cd 2+ ions, respectively. Under the optimized conditions, chelator was used for the quantification of important metals present in healthcare products via direct dissolution and furnace treatment during sample preparation. The results were found precise and accurate for both sample preparation techniques using the developed method. Copyright © 2017 Elsevier B.V. All rights reserved.
Umemura, Tomonari; Usami, Yosuke; Aizawa, Sho-ichi; Tsunoda, Kin-ichi; Satake, Ken-ichi
2003-12-30
The level of dissolved aluminum and its chemical forms in soil solutions consecutively collected by a porous cup vacuum sampler were monitored over a period from January 2001 to December 2001 at a Japanese cedar (Cryptomeria japonica) forestry area susceptible to acid deposition to characterize current soil dynamics and to evaluate potential tree damages. Distinction and characterization of Al species with differential toxicities were performed by two complementary speciation techniques; cation-exchange HPLC with fluorometric detection using 8-hydroxyquinoline-5-sulfonic acid (HQS) and size-fractionation/inductively coupled plasma atomic emission spectrometry (ICP-AES). The concentrations of free Al (mainly Al3+ and Al(OH)2+) and inert Al (existing as the complexed and/or colloidal forms) ranged between 0-150 microM and 10-50 microM, respectively. The concentrations of inert Al were mostly below 40 microM during an annual cycle and showed no marked seasonal variation, while free Al concentrations showed a clear tendency to increase in the spring and summer seasons (in the period from April to August) probably due to the enhanced activity of microbial nitrification and the resultant soil acidification. Major cations and anions were also regularly determined and their seasonal changes were correlated with that of the dissolved Al concentration. Correlations between total Al (mainly existing as free Al) and the related species (and environmental conditions) were as follows: Al and Mg (R=0.96, P<0.01), Al and Ca (R=0.97, P<0.01), Al and NO3- (R=0.68, P<0.01), Al and temperature (R=0.68, P<0.01), Al and solution pH (R=-0.61, P<0.01), solution pH and NO3- (R=-0.65, P<0.01).
Near-infrared fluorescent probes in cancer imaging and therapy: an emerging field
Yi, Xiaomin; Wang, Fuli; Qin, Weijun; Yang, Xiaojian; Yuan, Jianlin
2014-01-01
Near-infrared fluorescence (NIRF) imaging is an attractive modality for early cancer detection with high sensitivity and multi-detection capability. Due to convenient modification by conjugating with moieties of interests, NIRF probes are ideal candidates for cancer targeted imaging. Additionally, the combinatory application of NIRF imaging and other imaging modalities that can delineate anatomical structures extends fluorometric determination of biomedical information. Moreover, nanoparticles loaded with NIRF dyes and anticancer agents contribute to the synergistic management of cancer, which integrates the advantage of imaging and therapeutic functions to achieve the ultimate goal of simultaneous diagnosis and treatment. Appropriate probe design with targeting moieties can retain the original properties of NIRF and pharmacokinetics. In recent years, great efforts have been made to develop new NIRF probes with better photostability and strong fluorescence emission, leading to the discovery of numerous novel NIRF probes with fine photophysical properties. Some of these probes exhibit tumoricidal activities upon light radiation, which holds great promise in photothermal therapy, photodynamic therapy, and photoimmunotherapy. This review aims to provide a timely and concise update on emerging NIRF dyes and multifunctional agents. Their potential uses as agents for cancer specific imaging, lymph node mapping, and therapeutics are included. Recent advances of NIRF dyes in clinical use are also summarized. PMID:24648733
Rui, Qing-Qing; Zhou, Yi; Fang, Yuan; Yao, Cheng
2016-04-15
Two new rhodamine B-based fluorescent probes PyRbS and PyRbO containing pyrene moiety were designed and synthesized. Both of the probes showed colorimetric and fluorometric sensing abilities for Hg(2+) with high selectivity over other metal ions. The binding analysis using Job's plot suggested 1:1 stoichiometry for the complexes formed for Hg(2+). Compared with PyRbO, the PyRbS showed higher selectivity and sensitivity due to the thiophilic property of Hg(2+) ion. The PyRbS exhibited the linear fluorescence quenching to Hg(2+) in the range of 0.3 to 4.8 μM (λ(ex)=365 nm) and 0.3 to 5.4 μM (λ(ex)=515 nm), and the detection limit was 0.72 μM. Moreover, ratiometric changes of PyRbS with Hg(2+) in absorption spectrum were observed, which could not be obtained in the combination of PyRbO with Hg(2+). In addition, the methyl thiazolyl tetrazolium (MTT) assay demonstrated that RbPyS had low cytotoxicity and was successfully used to monitor intracellular Hg(2+) levels in living cells. Copyright © 2016 Elsevier B.V. All rights reserved.
Near-infrared fluorescent probes in cancer imaging and therapy: an emerging field.
Yi, Xiaomin; Wang, Fuli; Qin, Weijun; Yang, Xiaojian; Yuan, Jianlin
2014-01-01
Near-infrared fluorescence (NIRF) imaging is an attractive modality for early cancer detection with high sensitivity and multi-detection capability. Due to convenient modification by conjugating with moieties of interests, NIRF probes are ideal candidates for cancer targeted imaging. Additionally, the combinatory application of NIRF imaging and other imaging modalities that can delineate anatomical structures extends fluorometric determination of biomedical information. Moreover, nanoparticles loaded with NIRF dyes and anticancer agents contribute to the synergistic management of cancer, which integrates the advantage of imaging and therapeutic functions to achieve the ultimate goal of simultaneous diagnosis and treatment. Appropriate probe design with targeting moieties can retain the original properties of NIRF and pharmacokinetics. In recent years, great efforts have been made to develop new NIRF probes with better photostability and strong fluorescence emission, leading to the discovery of numerous novel NIRF probes with fine photophysical properties. Some of these probes exhibit tumoricidal activities upon light radiation, which holds great promise in photothermal therapy, photodynamic therapy, and photoimmunotherapy. This review aims to provide a timely and concise update on emerging NIRF dyes and multifunctional agents. Their potential uses as agents for cancer specific imaging, lymph node mapping, and therapeutics are included. Recent advances of NIRF dyes in clinical use are also summarized.
Substrates and method for determining enzymes
Smith, R.E.; Bissell, E.R.
1981-10-13
A method is disclosed for determining the presence of an enzyme in a biological fluid, which includes the steps of contacting the fluid with a synthetic chromogenic substrate, which is an amino acid derivative of 7-amino-4-trifluoromethylcoumarin; incubating the substrate-containing fluid to effect enzymatic hydrolysis; and fluorometrically determining the presence of the free 7-amino-4-trifluoromethylcoumarin chromophore in the hydrolyzate. No Drawings
Larsen, Torben; Aulrich, Karen
2012-02-01
Activity of the enzyme β-glucuronidase (EC 3.2.1.31) is found in milk from ruminants with mastitis. However, the use of this enzymic activity as an indicator of mastitis has gained little attention possibly because of its low activity when compared with other mastitis indicators. The determination may therefore be less precise and the analytical procedure very time consuming and labour intensive. The present study optimized the fluorometric determination of the β-glucuronidase activity with respect to substrate concentration, pH, incubation time etc., validated the assay, and developed it into large scale analyses. The assay performance is satisfactory regarding precision, linearity etc., and it appears comparable to analogous fluorometric assays for mastitis indicators in milk. From a local dairy herd, 825 milk samples were analysed for potential mastitis indicators, i.e. β-glucuronidase, lactate dehydrogenase (LDH), alkaline phosphatase (AP), and N-acetyl-β-d-glucosaminidase (NAGase) activity, and for somatic cell counts (SCC) and the variables were compared. Activity of β-glucuronidase was moderately but significantly correlated to SCC (r=0·21; n=768) as well as the other mentioned variables (r=0·25-0·43; n=825). Simple indices based on β-glucuronidase and LDH or NAGase activity were tested as indicators of mastitis (SCC), but were not found to improve the diagnostic value. Future studies may further verify whether β-glucuronidase can compete with well-established indicators of mastitis in cows such as LDH or NAGase as well as determine whether β-glucuronidase activity, in combination with other indicators of mastitis, has an advantage. Nineteen milk samples from subclinical and latent cases of mastitis (individual quarters) were identified for specific pathogens (PCR method) and measured for β-glucuronidase activity. The activity was tested at four different pH levels (5·5, 6·0, 6·5 and 7·0) in order to investigate the possibility of discrimination between pathogens. However, all milk samples (strains of pathogens) had the same pH optimum for β-glucuronidase activity; this may indicate that enzymic activity from mammary tissue and leucocytes dominates over enzyme activity from bacterial cells.
Qu, Kai; Shen, Nai-ying; Xu, Xin-sen; Su, Hai-bo; Wei, Ji-chao; Tai, Ming-hui; Meng, Fan-di; Zhou, Lei; Zhang, Yue-lang; Liu, Chang
2013-01-01
Aim: To elucidate the molecular mechanisms underlying the immunosuppressive effects of emodin isolated from Rheum palmatum L. Methods: Human T cells were isolated from the peripheral venous blood of 10 healthy adult donors. Cell viability was analyzed with MTT assay. AO/EB and Annexin V/PI staining and DNA damage assay were used to detect cell apoptosis. Fluorescence staining was used to detect the levels of ROS, the mitochondrial membrane potential and intracellular Ca2+. Colorimetry was used to detect the levels of MDA and total SOD and GSH/GSSG ratio. The expression and activity of caspase-3, -4, and -9 were detected with Western blotting and a fluorometric assay. Western blotting was also used to detect the expression of Bcl-2, Bax, cytochrome C, and endoplasmic reticulum (ER) markers. Results: Emodin (1, 10, and 100 μmol/L) inhibited the growth of human T cells and induced apoptosis in dose- and time dependent manners. Emodin triggered ER stress and significantly elevated intracellular free Ca2+ in human T cells. It also disrupted mitochondrial membrane potential, and increased cytosolic level of cytochrome C, and the levels of activated cleavage fragments of caspase-3, -4, and -9 in human T cells. Furthermore, emodin significantly increased the levels of ROS and MDA, inhibited both SOD level and GSH/GSSG ratio in human T cells, whereas co-incubation with the ROS scavenger N-acetylcysteine (NAC, 20 μmol/L) almost completely blocked emodin-induced ER stress and mitochondrial dysfunction in human T cells, and decreased the caspase cascade-mediated apoptosis. Conclusion: Emodin exerts immunosuppressive actions at least partly by inducing apoptosis of human T cells, which is triggered by ROS-mediated ER stress and mitochondrial dysfunction. PMID:23811723
Xu, Shenghao; Feng, Xiuying; Gao, Teng; Wang, Ruizhi; Mao, Yaning; Lin, Jiehua; Yu, Xijuan; Luo, Xiliang
2017-03-15
A novel ultrasensitive dual-functional biosensor for highly sensitive detection of inorganic pyrophosphate (PPi) and pyrophosphatase (PPase) activity was developed based on the fluorescent variation of globulin protected gold nanoclusters (Glo@Au NCs) with the assistance of Cu 2+ . Glo@Au NCs and PPi were used as the fluorescent indicator and substrate for PPase activity evaluation, respectively. In the presence of Cu 2+ , the fluorescence of the Glo@Au NCs will be quenched owing to the formation of Cu 2+ -Glo@Au NCs complex, while PPi can restore the fluorescence of the Cu 2+ -Glo@Au NCs complex because of its higher binding affinity with Cu 2+ . As PPase can catalyze the hydrolysis of PPi, it will lead to the release of Cu 2+ and re-quench the fluorescence of the Glo@Au NCs. Based on this mechanism, quantitative evaluation of the PPi and PPase activity can be achieved ranging from 0.05 μM to 218.125 μM for PPi and from 0.1 to 8 mU for PPase, with detection limits of 0.02 μM and 0.04 mU, respectively, which is much lower than that of other PPi and PPase assay methods. More importantly, this ultrasensitive dual-functional biosensor can also be successfully applied to evaluate the PPase activity in human serum, showing great promise for practical diagnostic applications. Copyright © 2016 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Stasyuk, Nataliya; Gayda, Galina; Zakalskiy, Andriy; Zakalska, Oksana; Errachid, Abdelhamid; Gonchar, Mykhailo
2018-03-01
A novel enzymatic method of manganese (II) and cobalt (II) ions assay, based on using apo-enzyme of Mn2 +-dependent recombinant arginase I (arginase) and 2,3-butanedione monoxime (DMO) as a chemical reagent is proposed. The principle of the method is the evaluation of the activity of L-arginine-hydrolyzing of arginase holoenzyme after the specific binding of Mn2 + or Co2 + with apo-arginase. Urea, which is the product of enzymatic hydrolysis of L-arginine (Arg), reacts with DMO and the resulted compound is detected by both fluorometry and visual spectrophotometry. Thus, the content of metal ions in the tested samples can be determined by measuring the level of urea generated after enzymatic hydrolysis of Arg by reconstructed arginase holoenzyme in the presence of tested metal ions. The linearity range of the fluorometric apo-arginase-DMO method in the case of Mn2 + assay is from 4 pM to 1.10 nM with a limit of detection of 1 pM Mn2 +, whereas the linearity range of the present method in the case of Co2 + assay is from 8 pM to 45 nM with a limit of detection of 2.5 pM Co2 +. The proposed method being highly sensitive, selective, valid and low-cost, may be useful to monitor Mn2 + and Co2 + content in clinical laboratories, food industry and environmental control service.
Tang, Cong; Qian, Zhaosheng; Huang, Yuanyuan; Xu, Jiamin; Ao, Hang; Zhao, Meizhi; Zhou, Jin; Chen, Jianrong; Feng, Hui
2016-09-15
A convenient, reliable and highly sensitive assay for alkaline phosphatase (ALP) activity in the real-time manner is developed based on β-cyclodextrin-modified carbon quantum dots (β-CD-CQDs) nanoprobe through specific host-guest recognition. Carbon quantum dots were first functionalized with 3-aminophenyl boronic acid to produce boronic acid-functionalized CQDs, and then further modified with hydropropyl β-cyclodextrins (β-CD) through B-O bonds to form β-CD-CQDs nanoprobe. p-Nitrophenol phosphate disodium salt is used as the substrate of ALP, and can hydrolyze to p-nitrophenol under the catalysis of ALP. The resulting p-nitrophenol can enter the cavity of β-CD moiety in the nanoprobe due to their specific host-guest recognition, where photoinduced electron transfer process between p-nitrophenol and CQDs takes place to efficiently quench the fluorescence of the probe. The correlation between quenched fluorescence and ALP level can be used to establish quantitative evaluation of ALP activity in a broad range from 3.4 to 100.0U/L with the detection limit of 0.9U/L. This assay shows a high sensitivity to ALP even in the presence of a very high concentration of glucose. This study demonstrates a good electron donor/acceptor pair, which can be used to design general detection strategy through PET process, and also broadens the application of host-guest recognition for enzymes detection in clinical practice. Copyright © 2016 Elsevier B.V. All rights reserved.
Lueders, Tillmann; Manefield, Mike; Friedrich, Michael W
2004-01-01
Stable isotope probing (SIP) of nucleic acids allows the detection and identification of active members of natural microbial populations that are involved in the assimilation of an isotopically labelled compound into nucleic acids. SIP is based on the separation of isotopically labelled DNA or rRNA by isopycnic density gradient centrifugation. We have developed a highly sensitive protocol for the detection of 'light' and 'heavy' nucleic acids in fractions of centrifugation gradients. It involves the fluorometric quantification of total DNA or rRNA, and the quantification of either 16S rRNA genes or 16S rRNA in gradient fractions by real-time PCR with domain-specific primers. Using this approach, we found that fully 13C-labelled DNA or rRNA of Methylobacterium extorquens was quantitatively resolved from unlabelled DNA or rRNA of Methanosarcina barkeri by cesium chloride or cesium trifluoroacetate density gradient centrifugation respectively. However, a constant low background of unspecific nucleic acids was detected in all DNA or rRNA gradient fractions, which is important for the interpretation of environmental SIP results. Consequently, quantitative analysis of gradient fractions provides a higher precision and finer resolution for retrieval of isotopically enriched nucleic acids than possible using ethidium bromide or gradient fractionation combined with fingerprinting analyses. This is a prerequisite for the fine-scale tracing of microbial populations metabolizing 13C-labelled compounds in natural ecosystems.
Sears, C.M.; Foose, M.P.; Day, G.W.; Ericksen, M.S.
1983-01-01
Semi-quantitative spectrographic analyses for 31 elements on rock, soil, fine-grained stream sediment, bulk stream sediment, and panned stream sediment samples collected in the Rich Mountain Roadless Area, Fannin and Gilmer Counties, Georgia, are reported here. Atomic absorption analyses for gold and fluorometric analyses for uranium are also reported. Brief descriptions of all rock samples analyzed are included.
2009-05-01
was measured on Mylar cards through fluorometric analysis. Plant health measures height and normalized difference vegetation index NDVI were...plant health data were used to generate dose-response relationships. Dose-response curves relating change in plant height and change in measured NDVI ...Held Sensor Model 505, NTech Industries, Inc., Ukiah, California to measure the normalized difference vegetation index NDVI which is directly
Photocatalytic activity of nanostructured ZnO-ZrO2 binary oxide using fluorometric method
NASA Astrophysics Data System (ADS)
Ibrahim, M. M.
2015-06-01
Evaluation of the photocatalytic activity of ZnO-ZrO2 nanomaterials using fluorescence based technique has rarely been reported. In the present work, ZnO-ZrO2 mixed oxides coupled with various ZnO dosages (0, 10, 30, 50, 70 wt%) were prepared by impregnation method. These nanomaterials were characterized by studying their structural, surface and optical properties. The photocatalytic activity in term of quantitative determination of the active oxidative species (radOH) produced on the surface of binary oxide was evaluated using fluorescent probe method. The interaction between ZnO and ZrO2 was affected on the photocatalytic efficiency of mixture. The results show that, the addition of ZnO to ZrO2 decreased the electron-hole recombination and increased the rate of radOH radicals formation. 50 wt% ZnO-ZrO2 photocatalyst exhibited much higher photocatalytic activity. The profound effect of binary oxide catalyst was generally considered due to the high surface area, small particle size, high monoclinic phase of ZrO2 content, low band gap and the presence of surface OH groups.
Kumari, Amrita; Koyama, Tetsuo; Hatano, Ken; Matsuoka, Koji
2016-10-01
A tetravalent GlcNAc pendant glycocluster was constructed with terminal biotin through C6 linker. To acquire the multivalent carbohydrate-protein interactions, we synthesized a glycopolymer of tetrameric structure using N-acetyl-d-glucosamine (GlcNAc) as the target carbohydrate by the use of 4-(4,6-dimethoxy-1,3,5-triazin-2-yl)-4-methylmorpholinium chloride (DMT-MM) as coupling reagent, followed by biotin-avidin complexation leading to the formation of glycocluster of avidin-biotin-GlcNAc conjugate (ABG complex). The dynamic light scattering (DLS) system was implied for size detection and to check the binding affinity of GlcNAc conjugate with a WGA lectin we use fluorometric assay by means of specific excitation of tryptophan at λex 295nm and it was found to be very high Ka∼1.39×10(7) M(-1) in case of ABG complex as compared to GlcNAc only Ka∼1.01×10(4) M(-1) with the phenomenon proven to be due to glycocluster effect. Copyright © 2016 Elsevier Inc. All rights reserved.
Min, Jun Zhe; Shimizu, Yoshiha; Toyo'oka, Toshimasa; Inagaki, Shinsuke; Kikura-Hanajiri, Ruri; Goda, Yukihiro
2008-10-01
To avoid the spreading of illegal drugs, a designated drug regulation system was introduced along with revision of the Pharmaceutical Affairs Law in Japan in 2006, and 32 substances including phenethylamine-type drugs were listed in April 2007. In this study, a new simultaneous determination method, based on ultra-fast liquid chromatography coupled with fluorescence detection (UFLC-FL), was developed for the 11 designated phenethylamine drugs. The phenethylamines were labeled with 4-(N,N-dimethylaminosulfonyl)-7-fluoro-2,1,3-benzoxadiazole (DBD-F) at 60 degrees C for 2h in 0.1M borax (pH 9.3). The resulting 11 fluorophores were completely separated by reversed-phase chromatography using an ACQUITY UPLC BEH C(18) column (2.1 mm x 100 mm 1.7 microm) and fluorometrically detected at 550 nm (excitation at 450 nm). The calibration curves obtained from the peak areas versus the injection amounts of the phenethylamines showed a good linearity. The limits of detection (signal-to-noise ratio of 3: S/N=3) on the chromatogram were in the range from 10 fmol (PMMA) to 2.5pmol (MMDA-2). Good accuracy (%) and precision (CV) by intra-day assay and inter-day assay were also obtained using the present procedure. The method was applied to the qualitative and quantitative analyses of phenethylamine in real products obtained from the Japanese market. As the results, BDB (0.24 mg/mg), MMDA-2 (0.98 mg/mL) and 2C-I (0.016 mg/mg) were identified from the different products (powder, liquid and mushroom like). Because the procedure is simple, selective and sensitive, the present method seems to be useful for the qualitative and quantitative analyses of the designated phenethylamines in various samples including biological specimens.
Kema, I P; Meijer, W G; Meiborg, G; Ooms, B; Willemse, P H; de Vries, E G
2001-10-01
Profiling of the plasma indoles tryptophan, 5-hydroxytryptophan (5-HTP), serotonin, and 5-hydroxyindoleacetic acid (5-HIAA) is useful in the diagnosis and follow-up of patients with carcinoid tumors. We describe an automated method for the profiling of these indoles in protein-containing matrices as well as the plasma indole concentrations in healthy controls and patients with carcinoid tumors. Plasma, cerebrospinal fluid, and tissue homogenates were prepurified by automated on-line solid-phase extraction (SPE) in Hysphere Resin SH SPE cartridges containing strong hydrophobic polystyrene resin. Analytes were eluted from the SPE cartridge by column switching. Subsequent separation and detection were performed by reversed-phase HPLC combined with fluorometric detection in a total cycle time of 20 min. We obtained samples from 14 healthy controls and 17 patients with metastasized midgut carcinoid tumors for plasma indole analysis. In the patient group, urinary excretion of 5-HIAA and serotonin was compared with concentrations of plasma indoles. Within- and between-series CVs for indoles in platelet-rich plasma were 0.6-6.2% and 3.7-12%, respectively. Results for platelet-rich plasma serotonin compared favorably with those obtained by single-component analysis. Plasma 5-HIAA, but not 5-HTP was detectable in 8 of 17 patients with carcinoid tumors. In the patient group, platelet-rich plasma total tryptophan correlated negatively with platelet-rich plasma serotonin (P = 0.021; r = -0.56), urinary 5-HIAA (P = 0.003; r = -0.68), and urinary serotonin (P <0.0001; r = -0.80). The present chromatographic approach reduces analytical variation and time needed for analysis and gives more detailed information about metabolic deviations in indole metabolism than do manual, single-component analyses.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hammel, Kenneth E.; Ralph, John; Hunt, Christopher G.
This work focused on new methods for the detection of oxidation in natural substrates during the deconstruction of lignocellulose by microoganisms. Oxidation was the focus because all known biological systems that degrade lignin are oxidative. The detection methods involved the used of (a) micrometer-scale beads carrying a fluorescent dye that is sensitive to oxidation, (b) 13C-labeled synthetic lignins whose breakdown products can be assessed using mass spectrometry and nuclear magnetic resonance spectroscopy, and (c) a fluorometric stain that is highly sensitive to incipient oxidation during microbial attack. The results showed (a) that one white rot fungus, Phanerochaete chrysosporium, produces diffusiblemore » oxidants on wood, and that the onset of oxidation is coincident with the marked up-regulation of genes that encode ligninolytic peroxidases and auxiliary oxidative enzymes; (b) that a more selectively ligninolytic white rot fungus, Ceriporiopsis subvermispora, produces a highly diastereoselective oxidative system for attack on lignin; (c) that a brown rot fungus, Serpula lacrymans, uses extracellular hydroquinone metabolites to drive the production of lignocellulose-oxidizing free radicals; (d) that both white rot and brown rot fungi produce highly diffusible mild oxidants that modify lignocellulose at the earliest stage of substrate deconstruction; and (e) that lignin degradation in a tropical soil is not inhibited as much as expected during periods of flooding-induced hypoxia, which indicates that unknown mechanisms for attack on lignin remain to be discovered.« less
Fluorometric Measurement of Pyridine Nucleotide Reduction in the Giant Axon of the Squid
Doane, Marshall G.
1967-01-01
By monitoring the fluorescence of the isolated giant axon of the squid Loligo pealei, it was possible to follow changes in its oxidation-reduction state as caused by the action of anoxia, cyanide, Amytal, and azide. The response to oxygen depletion was very rapid, the NAD within the axon being 90% reduced within 1–2 min. Cyanide and Amytal gave essentially similar results, although somewhat longer periods of time elapsed during their onset and washout periods. The extent of NAD reduction was essentially the same under conditions of anoxia and treatment with cyanide and Amytal. Azide was less effective in this respect, and at comparatively high levels of concentration (25–50 mM) gave values of 40% or less of the reduction observed with the other inhibitors. The application of ouabain and strophanthidin gave no observable NAD reduction. Variations in the time required to consume given quantities of dissolved oxygen before and after stimulation indicated an increase of 10–20% in oxygen uptake rate associated with activity, although this figure appeared to be a function of the surface-to-volume ratio of the axon. A biochemical analysis of axoplasm for oxidized and reduced pyridine nucleotide was made. Fluorometric examination of centrifuged axoplasm indicated that the NAD-NADH was largely confined to the mitochondria of the axon. PMID:4384698
Yi, Young-Joo; Sutovsky, Miriam; Kennedy, Chelsey; Sutovsky, Peter
2012-01-01
Inorganic pyrophosphate (PPi) is generated by ATP hydrolysis in the cells and also present in extracellular matrix, cartilage and bodily fluids. Fueling an alternative pathway for energy production in cells, PPi is hydrolyzed by inorganic pyrophosphatase (PPA1) in a highly exergonic reaction that can under certain conditions substitute for ATP-derived energy. Recombinant PPA1 is used for energy-regeneration in the cell-free systems used to study the zymology of ATP-dependent ubiquitin-proteasome system, including the role of sperm-borne proteasomes in mammalian fertilization. Inspired by an observation of reduced in vitro fertilization (IVF) rates in the presence of external, recombinant PPA1, this study reveals, for the first time, the presence of PPi, PPA1 and PPi transporter, progressive ankylosis protein ANKH in mammalian spermatozoa. Addition of PPi during porcine IVF increased fertilization rates significantly and in a dose-dependent manner. Fluorometric assay detected high levels of PPi in porcine seminal plasma, oviductal fluid and spermatozoa. Immunofluorescence detected PPA1 in the postacrosomal sheath (PAS) and connecting piece of boar spermatozoa; ANKH was present in the sperm head PAS and equatorial segment. Both ANKH and PPA1 were also detected in human and mouse spermatozoa, and in porcine spermatids. Higher proteasomal-proteolytic activity, indispensable for fertilization, was measured in spermatozoa preserved with PPi. The identification of an alternative, PPi dependent pathway for ATP production in spermatozoa elevates our understanding of sperm physiology and sets the stage for the improvement of semen extenders, storage media and IVF media for animal biotechnology and human assisted reproductive therapies. PMID:22485177
Yi, Young-Joo; Sutovsky, Miriam; Kennedy, Chelsey; Sutovsky, Peter
2012-01-01
Inorganic pyrophosphate (PPi) is generated by ATP hydrolysis in the cells and also present in extracellular matrix, cartilage and bodily fluids. Fueling an alternative pathway for energy production in cells, PPi is hydrolyzed by inorganic pyrophosphatase (PPA1) in a highly exergonic reaction that can under certain conditions substitute for ATP-derived energy. Recombinant PPA1 is used for energy-regeneration in the cell-free systems used to study the zymology of ATP-dependent ubiquitin-proteasome system, including the role of sperm-borne proteasomes in mammalian fertilization. Inspired by an observation of reduced in vitro fertilization (IVF) rates in the presence of external, recombinant PPA1, this study reveals, for the first time, the presence of PPi, PPA1 and PPi transporter, progressive ankylosis protein ANKH in mammalian spermatozoa. Addition of PPi during porcine IVF increased fertilization rates significantly and in a dose-dependent manner. Fluorometric assay detected high levels of PPi in porcine seminal plasma, oviductal fluid and spermatozoa. Immunofluorescence detected PPA1 in the postacrosomal sheath (PAS) and connecting piece of boar spermatozoa; ANKH was present in the sperm head PAS and equatorial segment. Both ANKH and PPA1 were also detected in human and mouse spermatozoa, and in porcine spermatids. Higher proteasomal-proteolytic activity, indispensable for fertilization, was measured in spermatozoa preserved with PPi. The identification of an alternative, PPi dependent pathway for ATP production in spermatozoa elevates our understanding of sperm physiology and sets the stage for the improvement of semen extenders, storage media and IVF media for animal biotechnology and human assisted reproductive therapies.
Proceedings of the Twelfth Conference on Environmental Toxicology 3, 4 and 5 November 1981
1982-04-01
energy spectrometry (XES) to localize the sites of asbestos deposition in the mucosa. After fixation in glutaraldehyde, tissues were critical point...fluorometrically before use. Mice were 8-12 weeks old when first treated. The mice were lightly anesthetized with Metofane® (Pitman-Moore, Inc., Washington Crossing...liver 71-127 109 19 (14%) Nephritis 93-138 109 9 ( 6%) Pneumonia, congestion and lung 68-134 109 inflammation 7 (5%) Spleen and liver necrosis 89-114 102
Microbial response to environmental gradients in a ceramic-based diffusion system.
Wolfaardt, G M; Hendry, M J; Birkham, T; Bressel, A; Gardner, M N; Sousa, A J; Korber, D R; Pilaski, M
2008-05-01
A solid, porous matrix was used to establish steady-state concentration profiles upon which microbial responses to concentration gradients of nutrients or antimicrobial agents could be quantified. This technique relies on the development of spatially defined concentration gradients across a ceramic plate resulting from the diffusion of solutes through the porous ceramic matrix. A two-dimensional, finite-element numerical transport model was used to predict the establishment of concentration profiles, after which concentration profiles of conservative tracers were quantified fluorometrically and chemically at the solid-liquid interface to verify the simulated profiles. Microbial growth responses to nutrient, hypochloride, and antimicrobial concentration gradients were then quantified using epifluorescent or scanning confocal laser microscopy. The observed microbial response verified the establishment and maintenance of stable concentration gradients along the solid-liquid interface. These results indicate the ceramic diffusion system has potential for the isolation of heterogeneous microbial communities as well as for testing the efficacy of antimicrobial agents. In addition, the durability of the solid matrix allowed long-term investigations, making this approach preferable to conventional gel-stabilized systems that are impeded by erosion as well as expansion or shrinkage of the gel. Copyright 2008 Wiley Periodicals, Inc.
Marschall, Robert; Tudzynski, Paul
2014-10-01
Reactive oxygen species (ROS) are produced in conserved cellular processes either as by-products of the cellular respiration in mitochondria, or purposefully for defense mechanisms, signaling cascades or cell homeostasis. ROS have two diametrically opposed attributes due to their highly damaging potential for DNA, lipids and other molecules and due to their indispensability for signaling and developmental processes. In filamentous fungi, the role of ROS in growth and development has been studied in detail, but these analyses were often hampered by the lack of reliable and specific techniques to monitor different activities of ROS in living cells. Here, we present a new method for live cell imaging of ROS in filamentous fungi. We demonstrate that by use of a mixture of two fluorescent dyes it is possible to monitor H2O2 and superoxide specifically and simultaneously in distinct cellular structures during various hyphal differentiation processes. In addition, the method allows for reliable fluorometric quantification of ROS. We demonstrate that this can be used to characterize different mutants with respect to their ROS production/scavenging potential. Copyright © 2014 Elsevier Inc. All rights reserved.
Adam Smith, R; Sewell, Sarah L; Giorgio, Todd D
2008-01-01
The development and in vitro performance of a modular nanoscale system capable of specific structural modification by enzymatic activity is described in this work. Due to its small physical size and adaptable characteristics, this system has the potential for utilization in targeted delivery systems and biosensing. Nanoparticle probes were synthesized containing two distinct fluorescent species including a quantum dot base particle and fluorescently labeled cleavable peptide substrate. Activity of these probes was monitored by gel electrophoresis with quantitative cleavage measurements made by fluorometric analysis. The model proximity-activated nanoparticles studied here exhibit significant susceptibility to cleavage by matrix metalloprotease-7 (MMP-7) at physiologically relevant concentrations, with nearly complete cleavage of available substrate molecules after 24 hours. This response is specific to MMP-7 enzyme activity, as cleavage is completely inhibited with the addition of EDTA. Utilization of enzyme-specific modification is a sensitive approach with broad applications for targeted therapeutics and biosensing. The versatility of this nanoparticle system is highlighted in its modular design, as it has the capability to integrate characteristics for detection, biosensing, targeting, and payload delivery into a single, multifunctional nanoparticle structure. PMID:18488420
NASA Astrophysics Data System (ADS)
Savoy, Steven M.; Lavigne, John J.; Yoo, J. S.; Wright, John; Rodriguez, Marc; Goodey, Adrian; McDoniel, Bridget; McDevitt, John T.; Anslyn, Eric V.; Shear, Jason B.; Ellington, Andrew D.; Neikirk, Dean P.
1998-12-01
A micromachined sensor array has been developed for the rapid characterization of multi-component mixtures in aqueous media. The sensor functions in a manner analogous to that of the mammalian tongue, using an array composed of individually immobilized polystyrene-polyethylene glycol composite microspheres selectively arranged in micromachined etch cavities localized o n silicon wafers. Sensing occurs via colorimetric or fluorometric changes to indicator molecules that are covalently bound to amine termination sites on the polymeric microspheres. The hybrid micromachined structure has been interfaced directly to a charged-coupled-device that is used for the simultaneous acquisition of the optical data from the individually addressable `taste bud' elements. With the miniature sensor array, acquisition of data streams composed of red, green, and blue color patterns distinctive for the analytes in the solution are rapidly acquired. The unique combination of carefully chosen reporter molecules with water permeable microspheres allows for the simultaneous detection and quantification of a variety of analytes. The fabrication of the sensor structures and the initial colorimetric and fluorescent responses for pH, Ca+2, Ce+3, and sugar are reported. Interface to microfluidic components should also be possible, producing a complete sampling/sensing system.
Fluorometric aptamer based assay for ochratoxin A based on the use of exonuclease III.
Liu, Renjie; Wu, Hua; Lv, Lei; Kang, Xiaojiao; Cui, Chengbi; Feng, Jin; Guo, Zhijun
2018-04-14
This study describes an aptamer based assay for the mycotoxin ochratoxin A (OTA). The method is based on the use of an OTA-specific aptamer, exonuclease (Exo) III, SYBR Gold as a fluorescent probe, and a complementary strand that specifically combines with the aptamer. In the presence of OTA, the aptamer and OTA hybridize, thereby resulting in the formation of ssDNA, which is not digested by Exo III. Intense fluorescence is observed after addition of SYBR Gold (best measured at excitation/emission wavelengths of 495/540 nm). Fluorescence increases linearly with the log of the OTA concentration in the range from 8 to 1000 ng·mL -1 . The detection limit is 4.7 ng·mL -1 . The assay was applied to the determination of OTA in diluted [2%(v/v)] red wine, and recoveries and RSDs ranged between 93.5% and 113.8%, and between 3.2% and 5.7%, respectively. Graphical abstract In the presence of ochratoxin A (OTA), specific combinations of aptamer and OTA may occur and result in DNA double strands being untied, which avoids being digested by Exo III. Intense fluorescence is observed after SYBR Gold addition.
NASA Astrophysics Data System (ADS)
Aree, Thammarat; Arunchai, Rungthiwa; Koonrugsa, Narongsak; Intasiri, Amarawan
2012-10-01
Inclusion complexes of β-cyclodextrin (β-CD) with L- and D-phenylalanine (Phe) have been characterized in solution by fluorometry and in gas phase by semiempirical PM3 calculations. The unimolar stoichiometric ratio of both β-CD-L-Phe and β-CD-D-Phe complexes and the stability constants (K) were deduced from fluorometric titrations. The β-CD-L-Phe complex is more stable than the β-CD-D-Phe complex as indicated by the larger K values, 21.1 vs. 6.86 M-1. This is consistent with the stabilization energies (ΔEstb) and inclusion geometries obtained from PM3 calculations. The β-CD-L-Phe complex with L-Phe residing in the central β-CD cavity and pointing its COOH group downwards to the O6 end has ΔEstb = -62.7 kJ mol-1, whereas the β-CD-D-Phe complex with D-Phe placing at 3 Å beneath the β-CD O4-plane and pointing its COOH group upwards to the O2/O3 end has ΔEstb = -53.3 kJ mol-1. The unison of host-guest intermolecular hydrogen bonds, hydrophobic interactions and molecular deformations plays an essential role in forming and stabilizing the inclusion complexes. Our results show that the β-CD-L-Phe and β-CD-D-Phe inclusion complexes are relatively stable and differentiable, suggesting the applications of CDs in foods and drugs.
NASA Astrophysics Data System (ADS)
Ali, Anwar; Malik, Nisar Ahmad; Uzair, Sahar; Ali, Maroof
2014-10-01
The critical micelle concentration (CMC) of sodium dodecyl sulphate (SDS) in pure water and in the presence of amino acids (0.01, 0.02 and 0.03 mol kg-1), L-valine (Val) and L-leucine (Leu) was determined from conductometric and fluorometric methods using pyrene as luminescence probe. Depression in the CMC at low concentration of amino acids is attributed to the increased hydrophobic-hydrophobic interaction between the non-polar groups of the surfactant, while, at high concentration, amino acids bind strongly with the anion, DS-, head groups of SDS, thereby, delaying the micelle formation, resulting in increased CMC. A pronounced decrease in the CMC, while a marked increase in λ0+, with decrease in the solvated radius (rather than crystal radius) of the counterions is observed. Negative values of ΔG0m and ΔH0m indicate that micellisation of SDS in the presence of amino acids is thermodynamically spontaneous and exothermic. Highest negative value of ΔH0m in 0.01 m Val, with lowest CMC value, shows that 0.01 m aqueous Val is the most suitable medium favouring the micellisation of SDS. Decrease in I1/I3 from Val to Leu confirms the relative hydrophobicity of two amino acids. The observed values of the packing parameter, P, of SDS in water and in aqueous amino acids suggest that micelles formed are spherical in nature.
Murakami, Chiaki; Mizuno, Satoru; Kado, Sayaka; Sakane, Fumio
2017-06-01
Phosphatidylcholine (PC)-specific phospholipase C (PC-PLC) hydrolyzes PC to generate the second messenger 1,2-diacylglycerol (DG) and phosphocholine. PC-PLC plays pivotal roles in inflammation, carcinogenesis, tumor progression, atherogenesis, and subarachnoid hemorrhage. Although the activity of PC-PLC in mammalian tissues was discovered approximately 40 years ago, neither the protein nor its gene has been identified. In the present study, we developed a non-radioactive enzyme activity assay for PC-PLC based on mass spectrometric detection of DG following HPLC separation. This new liquid chromatography-mass spectrometry (LC-MS) assay directly determines a specific reaction product, 1-palmitoyl-2-oleoyl-DG, that is generated from 1-palmitoyl-2-oleoyl-PC by purified Bacillus cereus PC-PLC. The LC-MS assay offers several advantages including a lower background (0.02% versus 91%), higher signal background ratio (4242 versus 1.06)/signal noise ratio (7494 versus 4.4), higher sensitivity (≥32-fold), and lower limit of quantitation (0.04 pmol versus 0.69 pmol of PC-PLC), than a conventional fluorometric assay, which indirectly detects phosphocholine produced in the reaction. In addition to Bacillus cereus PC-PLC, the LC-MS assay was applicable to the measurement of mammalian PC-PLC prepared from the mouse brain. The radioisotope-free, highly sensitive and precise LC-MS assay for PC-PLC would be useful for the purification and identification of PC-PLC protein. Copyright © 2017 Elsevier Inc. All rights reserved.
Tian, Jun; Ban, Xiaoquan; Zeng, Hong; He, Jingsheng; Chen, Yuxin; Wang, Youwei
2012-01-01
The essential oil extracted from the seeds of dill (Anethum graveolens L.) was demonstrated in this study as a potential source of an eco-friendly antifungal agent. To elucidate the mechanism of the antifungal action further, the effect of the essential oil on the plasma membrane and mitochondria of Aspergillus flavus was investigated. The lesion in the plasma membrane was detected through flow cytometry and further verified through the inhibition of ergosterol synthesis. The essential oil caused morphological changes in the cells of A. flavus and a reduction in the ergosterol quantity. Moreover, mitochondrial membrane potential (MMP), acidification of external medium, and mitochondrial ATPase and dehydrogenase activities were detected. The reactive oxygen species (ROS) accumulation was also examined through fluorometric assay. Exposure to dill oil resulted in an elevation of MMP, and in the suppression of the glucose-induced decrease in external pH at 4 µl/ml. Decreased ATPase and dehydrogenase activities in A. flavus cells were also observed in a dose-dependent manner. The above dysfunctions of the mitochondria caused ROS accumulation in A. flavus. A reduction in cell viability was prevented through the addition of L-cysteine, which indicates that ROS is an important mediator of the antifungal action of dill oil. In summary, the antifungal activity of dill oil results from its ability to disrupt the permeability barrier of the plasma membrane and from the mitochondrial dysfunction-induced ROS accumulation in A. flavus.
Renauld, A.E.; Melancon, M.J.; Sordillo, L.M.
1999-01-01
Seven modulators of mammalian monooxygenase activity were screened for their ability to selectively stimulate or inhibit in vitro monooxygenase activities of hepatic microsomes from mallard ducklings treated with phenobarbital, β-naphthoflavone, 3,3′,4,4′,5-pentachlorobiphenyl or vehicle. Microsomes were assayed fluorometrically for four monooxygenases: benzyloxy-, ethoxy-, methoxy-, and pentoxyresorufin-O-dealkylase, in combination with each of the seven modulators. Four combinations: α-naphthoflavone and 2-methylbenzimidazole with benzyloxyresorufin, and Proadifen with methoxy- and ethoxyresorufin, respectively, were evaluated further. β-Naphthoflavone-treated groups were clearly distinguished from the corn oil vehicle control group by all of the assays and by the effects of the modulators in three of the four assay/modulator combinations. Enzyme activities of the phenobarbital and saline groups were statistically similar (P≥0.05) when assayed without modulator added, but each assay/modulator combination distinguished between these groups. The PCB-treated group was distinguished from the corn oil vehicle control group only for BROD activity, with or without the presence of modulator. Graphing of per cent modulation of BROD activity versus initial BROD activity provided the clearest distinction between all of the study groups. Identification of these selective in vitro modulators may improve detection and measurement of low level cytochrome P450 induction in avian species. Also, both the monooxygenase activities induced and the impacts of the modulators indicated differences between mammalian and avian cytochromes P450.
Calvo-Begueria, Laura; Rubio, Maria C; Martínez, Jesús I; Pérez-Rontomé, Carmen; Delgado, Maria J; Bedmar, Eulogio J; Becana, Manuel
2018-04-26
Nitric oxide (NO) is a signaling molecule with multiple functions in plants. Given its critical importance and reactivity as a gaseous free radical, we have examined NO production in legume nodules using electron paramagnetic resonance (EPR) spectroscopy and the specific fluorescent dye 4,5-diaminofluorescein diacetate. Also, in this context, we critically assess previous and current views of NO production and detection in nodules. EPR of intact nodules revealed that nitrosyl-leghemoglobin (Lb2+NO) was absent from bean or soybean nodules regardless of nitrate supply, but accumulated in soybean nodules treated with nitrate that were defective in nitrite or nitric oxide reductases or that were exposed to ambient temperature. Consequently, bacteroids are a major source of NO, denitrification enzymes are required for NO homeostasis, and Lb2+NO is not responsible for the inhibition of nitrogen fixation by nitrate. Further, we noted that Lb2+NO is artifactually generated in nodule extracts or in intact nodules not analyzed immediately after detachment. The fluorescent probe detected NO formation in bean and soybean nodule infected cells and in soybean nodule parenchyma. The NO signal was slightly decreased by inhibitors of nitrate reductase but not of nitric oxide synthase, which could indicate a minor contribution of plant nitrate reductase and supports the existence of nitrate- and arginine-independent pathways for NO production. Collectively, our data indicate that EPR and fluorometric methods are complementary to draw reliable conclusions about NO production in plants.
Šimšíková, Michaela; Čechal, Jan; Zorkovská, Anna; Antalík, Marián; Šikola, Tomáš
2014-11-01
Cysteine and homocysteine play a crucial role in many biological functions but abnormal levels of these amino acids may lead to various forms of pathogenesis. Therefore, selective and easy-to-use methods for the detection of cysteine and homocysteine are essential for the early diagnosis of developing diseases. In this paper we report on a rapid, straightforward and highly selective method for the detection of cysteine (Cys) and homocysteine (Hcy) which uses a CuO/ZnO nanocomposite as a dual colorimetric and fluorometric assay. The presence of Cys and Hcy in a solution of these nanorods (NRs) induces a change in its color from light blue to dark grey which is visible to the naked eye. This is accompanied by a blue shift in the absorption spectra from 725 nm to 650 nm and a decrease in the intensity of CuO/ZnO nanocomposite emission. These changes are ascribed to the reduction of Cu(II) to Cu(0), and the oxidation of cysteine (homocysteine) and subsequent formation of the disulfide bond. This novel assay method does not respond to any other amino-acid which is present in living organisms; therefore the selective determination of cysteine (homocysteine) with a lower analyte limit of 40 μM (4.8 μg mL(-1)) can be carried out in aqueous solutions without the need for any sophisticated instrumentation, fluorophore molecules or complicated procedures. Copyright © 2014 Elsevier B.V. All rights reserved.
Liu, Yanyan; Li, Hongchang; Guo, Bin; Wei, Lijuan; Chen, Bo; Zhang, Youyu
2017-05-15
Herein we report a novel switch-off fluorescent probe for highly selective determination of uric acid (UA) based on the inner filter effect (IFE), by using poly-(vinylpyrrolidone)-protected gold nanoparticles (PVP-AuNPs) and chondroitin sulfate-stabilized gold nanoclusters (CS-AuNCs) as the IFE absorber/fluorophore pair. In this IFE-based fluorometric assay, the newly designed CS-AuNCs were explored as an original fluorophore and the hydrogen peroxide (H 2 O 2 ) -driven formed PVP-AuNPs can be a powerful absorber to influence the excitation of the fluorophore, due to the complementary overlap between the absorption band of PVP-AuNPs and the emission band of CS-AuNCs. Under the optimized conditions, the extent of the signal quenching depends linearly on the H 2 O 2 concentration in the range of 1-100μM (R 2 =0.995) with a detection limit down to 0.3μM. Based on the H 2 O 2 -dependent fluorescence IFE principle, we further developed a new assay strategy to enable selective sensing of UA by using a specific uricase-catalyzed UA oxidation as the in situ H 2 O 2 generator. The proposed uricase-linked IFE-based assay exhibited excellent analytical performance for measuring UA over the concentration ranging from 5 to 100μM (R 2 =0.991), and can be successfully applied to detection of UA as low as 1.7μM (3σ) in diluted human serum samples. Copyright © 2017 Elsevier B.V. All rights reserved.
Saito, Shingo; Massie, Tara L; Maeda, Takeshi; Nakazumi, Hiroyuki; Colyer, Christa L
2012-01-01
Fluorescence sensing of saccharides and glycoproteins using a boronic acid functionalized squarylium cyanine dye ("SQ-BA") is characterized in terms of synthetic, fluorometric, thermodynamic and kinetic parameters. In our previous work, this newly synthesized dye was successfully applied to the separation and quantification of Gram-positive bacteria by capillary electrophoresis with laser-induced fluorescence detection (CE-LIF); however, the fundamental properties of the dye and its saccharide complexes still required elucidation, as presented in this paper. The dye itself forms nonemissive, soluble aggregates in aqueous solution. With the addition of a monosaccharide, the dye aggregate dissociates to form an emissive monomer accompanied by the formation of a cyclic cis-diol ester with long-wavelength emission (λ(ex) = 630 nm, λ(em) = 660 nm). A very large fluorescence enhancement factor of 18× was observed for the sensing dye as a fructose complex at pH 10, yielding a limit of detection of 10 μM fructose. The relative order of fluorescence enhancement of SQ-BA with other monosaccharides was found to be: fructose > ribose > arabinose ≈ galactose > xylose > mannose > rhamnose > fucose ≈ glucose; and apparent affinity constants of 10(2.80), 10(2.08) and 10(0.86) M(-1) were determined for fructose, ribose and glucose, respectively. Formation of the emissive complexes occurred within minutes, proving the kinetics of the sugar-dye interactions to be suitable for on-column labeling methods in CE-LIF. Furthermore, the sensing dye was successfully applied to glycoproteins, mucin type I-S and type III, which were detected with high sensitivity in batch aqueous solution as a result of the sugar-selective boronic acid-diol esterification as well as hydrophobic interactions.
Saito, Shingo; Massie, Tara L.; Maeda, Takeshi; Nakazumi, Hiroyuki; Colyer, Christa L.
2012-01-01
Fluorescence sensing of saccharides and glycoproteins using a boronic acid functionalized squarylium cyanine dye (“SQ-BA”) is characterized in terms of synthetic, fluorometric, thermodynamic and kinetic parameters. In our previous work, this newly synthesized dye was successfully applied to the separation and quantification of Gram-positive bacteria by capillary electrophoresis with laser-induced fluorescence detection (CE-LIF); however, the fundamental properties of the dye and its saccharide complexes still required elucidation, as presented in this paper. The dye itself forms nonemissive, soluble aggregates in aqueous solution. With the addition of a monosaccharide, the dye aggregate dissociates to form an emissive monomer accompanied by the formation of a cyclic cis-diol ester with long-wavelength emission (λex = 630 nm, λem = 660 nm). A very large fluorescence enhancement factor of 18× was observed for the sensing dye as a fructose complex at pH 10, yielding a limit of detection of 10 μM fructose. The relative order of fluorescence enhancement of SQ-BA with other monosaccharides was found to be: fructose > ribose > arabinose ≈ galactose > xylose > mannose > rhamnose > fucose ≈ glucose; and apparent affinity constants of 102.80, 102.08 and 100.86 M−1 were determined for fructose, ribose and glucose, respectively. Formation of the emissive complexes occurred within minutes, proving the kinetics of the sugar-dye interactions to be suitable for on-column labeling methods in CE-LIF. Furthermore, the sensing dye was successfully applied to glycoproteins, mucin type I–S and type III, which were detected with high sensitivity in batch aqueous solution as a result of the sugar-selective boronic acid-diol esterification as well as hydrophobic interactions. PMID:22778592
Rhouati, Amina; Nasir, Muhammad; Marty, Jean-Louis; Hayat, Akhtar
2017-12-06
The authors describe an analytical detection scheme based on the use of multiwalled carbon nanotubes (MWCNTs) that accept and store electrons upon contact with photo-irradiated TiO 2 nanoparticles (TiO 2 -NPs). The Fermi level equilibration with photo-irradiated TiO 2 -NPs has a storage value of 0.35 mM of electrons per 120 mg·L -1 of MWCNTs. The stored electrons can be discharged on demand upon addition of electron acceptors to the TiO 2 -NP/MWCNT composite. These findings are applied to detect the quencher hydrogen peroxide. H 2 O 2 also is produced on enzymatic action of glucose oxidase on glucose, and this enables glucose also to be quantified by using the TiO 2 -NP/MWCNT fluorescent nanoprobe. The wide scope of the method also is demonstrated by an assay for aflatoxin B1 that is making use of an FAM-labeled aptamer where the FAM fluorophore on the aptamer quenches the emission of the nanoprobe. The following analytical linear ranges and limits of detection are found: H 2 O 2 : 0.1-100 μM and 15 nM; glucose: 5-200 μM and 0.5 μM; aflatoxin: 0.1-40 ng·mL -1 and 0.02 ng·mL -1 . The method was applied to the determination of glucose in human serum. Graphical abstract The assays demonstrated in (b) and (c) are based on the fluorescence quenching ability of MWCNTs-TiO 2 . In the presence of the target (analyte), the fluorescence is restored and the target concentration is determined from the percentage of fluorescence recovery.
NASA Astrophysics Data System (ADS)
Chandra, Sulekh; Vandana; Kumar, Suresh
2015-01-01
Schiff's base ligand(L) hydrazine carboxamide, 2-[3-methyl-2-thienyl methylene] and its metal complexes have been synthesized and characterized by elemental analysis, molar conductance, various spectroscopic techniques such as electronic, IR, 1H NMR, mass, EPR. Molar conductance of complexes in DMF solution corresponds to non-electrolyte. Complexes have general composition [M(L)2X2], where M = Ni(II) and Cu(II), X = Cl-, NO3-, CH3COO- and ½SO42-. On the basis of above spectral studies, an octahedral geometry has been assigned for Ni(II) complexes and tetragonal geometry for Cu(II) complexes except [Cu(L)2SO4] which possesses five coordinated trigonal bipyramidal geometry. These metal complexes were also tested for their anticancer, antibacterial and antifungal activities to assess their inhibition potential. Anticancer activity of ligand and its metal complexes were evaluated using SRB fluorometric assay and Adriamycin (ADR) was applied as positive control. Schiff's base ligand and its metal complexes were screened for their antibacterial and antifungal activity against Escherichia coli, Bacillus cereus and Aspergillus niger, Aspergillus flavus, respectively. Kirby-Bauer single disk susceptibility test was used for antibacterial activity and well diffusion method for antifungal activity of the compounds on the used fungi.
Hydrogen Ion Buffering During Complete Brain Ischemia
KRAIG, RICHARD P.; PULSINELLI, WILLIAM A.; PLUM, FRED
2011-01-01
As a first step to quantify [H+] changes in brain during ischemia we used H+-selective microelectrodes and enzyme fluorometric techniques to describe the relationship between interstitial [H+] ([H+]o) and peak tissue lactate after cardiac arrest. We found a step function relationship between [H+]o and tissue lactate rather than the linear titration expected in a homogeneous protein solution. Within a blood glucose range from 3–7 mM, brain lactate rose from 8–13 mmol/kg along with a rise in [H+]o of 99 ± 6 nM (0.44 ± 0.02 pH). At higher blood glucose levels (17–80 mM), brain lactate accumulated to levels of 16–31 mmol/kg; concurrently [H+]o rose by 608 ± 16 nM (1.07 ± 0.02 pH). The unchanging level of [H+]o between 8–13 and 16–31 mmol/kg lactate implies that [H+]o is at a steady-state, but not equilibrium with respect to [H+] in other brain compartments. We propose that ion-transport characteristics of astroglia account for the observed relationship of [H+]o to tissue lactate during complete ischemia and suggest that brain infarction develops after plasma membranes in brain cells can no longer transport ions to regulate [H+]. PMID:4041829
Azizi, Seyed Naser; Chaichi, Mohammad Javad; Shakeri, Parmis; Bekhradnia, Ahmadreza
2015-07-05
A novel fluorescence (FL) method using water-soluble CdSe quantum dots (QDs) is proposed for the fluorometric determination of hydrogen peroxide and glucose. Water-soluble CdSe QDs were synthesized by using thioglycolic acid as stabilizer in aqueous solutions. The nanoparticles were structurally and optically characterized by X-ray powder diffraction (XRD), dynamic light scattering (DLS), Fourier transform infrared spectroscopy (FTIR), UV-Vis absorption spectroscopy, photoluminescence (PL) emission spectroscopy and transmission electron microscope (TEM). Ionic liquid-sensitized effect in aqueous solution was then investigated. In the presence of ionic liquid as catalyst, H2O2 was decomposed into radical that could quench the fluorescence of CdSe QDs more efficiently and rapidly. Then the oxidization of glucose by glucose oxidase was coupled with the fluorescence quenching of CdSe QDs by H2O2 producer with ionic liquid catalyst, which can be used to detect glucose. Therefore, a new FL analysis system was developed for the determination of glucose. Under the optimum conditions, there is a good linear relationship between the relative PL emission intensity and the concentration of glucose in the range of 5.0×10(-7)-1.0×10(-4) M of glucose with a correlation coefficient (R(2)) of 0.9973. The limit of detection of this system was found to be 1.0×10(-7) M. This method is not only simple, sensitive and low cost, but also reliable for practical applications. Copyright © 2015. Published by Elsevier B.V.
Paganin, F; Bouvet, O; Chanez, P; Fabre, D; Galtier, M; Godard, P; Michel, F B; Bressolle, F
1995-07-01
Infectious excerbations of COPD are generally due to Streptococcus pneumoniae, Haemophilus species, and other Gram-negative bacteria. Ofloxacin has potent activity against Gram-negative species but is less effective against Gram-positive species including Streptococcus pneumoniae. It has also been shown that the administration of ambroxol increases the concentration of some antibiotics in pulmonary tissues. The aim of the study was to determine whether ambroxol increases the bronchial tissue concentrations of ofloxacin to a level exceeding the MIC90 of the bacterial species less susceptible to ofloxacin. 24 patients with COPD were randomized in two groups. Drug regimens of ofloxacin alone (200 mg twice daily) or ofloxacin (200 mg twice daily)+ambroxol (30 mg thrice daily) were administered over 10 d. A fibroscopy was performed on day 10 with bronchial biopsies and broncho-alveolar lavage. At steady state, concentrations of drug in plasma and bronchial samples were assayed by HPLC with fluorometric detection. There was no significant difference in the bronchial levels of ofloxacin between the two groups; however, in alveolar cells, ofloxacin concentration was three times higher in the group with ambroxol. Ambroxol does not increase ofloxacin concentrations in bronchial tissue because high concentrations are already present in the lung.
Walash, Mohamed I; Belal, Fathalla; El-Enany, Nahed; Abdelal, Amina
2008-01-01
A rapid, simple, and highly sensitive second-derivative synchronous fluorometric method has been developed for the simultaneous analysis of binary mixtures of cinnarizine (CN) and nicergoline (NIC). The method is based upon measurement of the native fluorescence of these drugs at constant wavelength difference (Deltalambda) = 80 nm in aqueous methanol (50%, v/v). The different experimental parameters affecting the native fluorescence of the studied drugs were carefully studied and optimized. The fluorescence-concentration plots were rectilinear over the range of 0.025-1.5 and 0.25-5.5 microg/mL for CN and NIC, respectively, with lower detection limits of 0.58 and 0.82 ng/mL and quantitation limits of 1.93 and 2.73 ng/mL for CN and NIC, respectively. The proposed method was successfully applied for the determination of the studied compounds in synthetic mixtures and in commercial tablets. The results obtained were in good agreement with those obtained with reference methods. The high sensitivity attained by the proposed method allowed the determination of CN in real and spiked human plasma. The mean recovery in the case of spiked human plasma [number of trials (n) = 3] was 102.82 +/- 2.17%, while that in real human plasma (n = 3) was 105.25 +/- 2.05.
Advanced Glycation End-products and Bone Fractures.
Vashishth, Deepak
2009-08-01
Bone does not turn over uniformly, and becomes susceptible to post-translational modification by non-enzymatic glycation (NEG). NEG of bone causes the formation of advanced glycation end-products (AGEs) and this process is accelerated with aging, diabetes and antiresorptive postmenopausal osteoporosis therapy. Due to the elevated incidence of fracture associated with aging and diabetes, several studies have attempted to measure and evaluate AGEs as biomarkers for fracture risk. Here current methods of estimating AGEs in bone by liquid chromatography and fluorometric assay are summarized and the relationships between AGEs and fracture properties at whole bone, apparent tissue and matrix levels are discussed.
Prevalence of glucose-6-phosphate dehydrogenase deficiency in neonates in Egypt.
Elella, Soheir Abo; Tawfik, Mahaa; Barseem, Naglaa; Moustafa, Wafaa
2017-01-01
Glucose-6-phosphate dehydrogenase (G6PD) deficiency is an X-linked disorder which causes neonatal jaundice in most cases, and under certain conditions, can cause a spectrum of hemolytic manifestations. To determine the local prevalence of G6PD deficiency in newborns. Cross-sectional. University hospital. Infants born during 2015 were prospectively screened for G6PD deficiency. Dried blood spot samples on filter paper were collected in collaboration with the central laboratories of the Ministry of Health. Quantitative measurement of G6PD enzyme activity was measured from the blood samples using fluorometric analysis. A value.
Crochet, John R; Shah, Anish A; Schomberg, David W; Price, Thomas M
2012-09-01
Trophoblast-derived human chorionic gonadotropin (hCG) promotes corpus luteum progesterone (P4) production, and wide ranges of serum P4 levels are noted in various pregnancy outcomes, despite similar hCG concentrations. There are five unique biologically active hCG variants in human pregnancy urine, and previous studies of P4 production in response to hCG have used only preparations containing all isoforms. Understanding exactly which hCG variant is primarily responsible for stimulating corpus luteum steroidogenesis may have great clinical and diagnostic implications, including in the setting of ectopic pregnancy. Our objective was to delineate the role of the standard and hyperglycosylated (H)-hCG isoforms in stimulating P4 production by luteinized granulosa cells. Cell culture, ELISA, and fluorometric-based protein assays were done at Duke University Medical Center. Patients were anonymous oocyte donors. Cultured luteinized granulosa cells were treated with 0.25, 0.5, and 1.0 ng/ml total hCG, which contains all isoforms, purified standard hCG (37.1 kDa), and purified H-hCG (42.8 kDa). P4 produced per total cellular protein (nanograms per microgram) was measured via ELISA and fluorometric protein determination kits. Both total hCG (P = 0.0003) and purified standard hCG (P < 0.0001) stimulated a dose-dependent increase in P4 production. Purified H-hCG did not change the P4 produced per total cellular protein response (P value not significant). Standard hCG stimulated P4 production by cultured granulosa cells and likely supports corpus luteum function via interactions with the LH/hCG receptor. In contrast, H-hCG did not increase P4 production, which indicates a nonsteroidogenic role for this protein during early gestation.
Siesto, Gabriele; Romano, Fabrizio; Fiamengo, Barbara; Vitobello, Domenico
2016-01-01
Sentinel lymph node (SLN) mapping has emerged as the new frontier for the surgical staging of apparently early-stage cervical and endometrial cancer. Different colorimetric and radioactive tracers, alone and in combination, have been proposed with encouraging results. Fluorometric mapping using indocyanine green (ICG) appears to be a suitable and attractive alternative to provide reliable staging [1-4]. In this video, we present the technique of SLN mapping in 2 cases (1 endometrial and 1 cervical cancer, respectively) using ICG and the near-infrared technology provided by the newest Da Vinci Xi robotic system (Intuitive Surgical Inc., Sunnyvale, CA). Together we report the results of our preliminary experience on the first 20 cases performed. The new robotic Da Vinci Xi system was available at our institution since May 2015. Upon institutional review board/ethical committee approval, all consecutive patients with early-stage endometrial and cervical cancer who were judged suitable for robotic surgery have been enrolled for SLN mapping with ICG. We adopted the Memorial Sloan Kettering Cancer Center SLN algorithm; the tracer was delivered into the cervix in all cases. Four milliliters (1.25 mg/mL) of ICG was injected divided into the 3- and 9-o'clock positions of the cervix alone, with 1 mL deep into the stroma and 1 mL submucosally at the skin incision. Sentinel lymph nodes were examined with a protocol including both ultrastaging with immunohistochemistry [3] and 1-step nucleic acid amplification assay [5,6] under a parallel protocol of study. During the study period, 20 cases were managed; 14 and 6 patients had endometrial and cervical cancer, respectively. SLN was detected in all cases (20/20, 100%). Bilateral SLNs were detected in 17 of 20 (85.0%) cases. Based on preoperative and intraoperative findings, 13 (65.0%) patients received systematic pelvic lymphadenectomy after SLN mapping. Three (15.0%) patients had microscopic nodal metastases on SLN. No patients had positive regional nodes other than SLN. No perioperative complications were recorded. SLN mapping has been acknowledged by the National Comprehensive Cancer Network guidelines as a viable option for the management of selected uterine malignancies [7,8]. Currently, the near-infrared technology built in the Da Vinci Xi system provides an enhanced real-time imaging system that improves the advantages given by ICG. Together with our experience, these conditions indicate that SLN mapping is an effective and safe procedure with high overall detection and low false-negative rates. Copyright © 2016 AAGL. Published by Elsevier Inc. All rights reserved.
Monserrat, J M; Seixas, A L R; Ferreira-Cravo, M; Bürguer-Mendonça, M; Garcia, S C; Kaufmann, C G; Ventura-Lima, J
2017-06-01
Nanomaterials (NM) exhibit unique properties due their size and relative area, but the mechanisms and effects in the living organisms are yet to be unfold in their totality. Potential toxicity mechanisms concerning NM as carbon nanotubes include oxidative stress generation. Several fluorimetric and colorimetric methods have been systematically used to measure NM toxicity, and controversial results have been reported. One of the problems can be related to the interference effects induced by NM, leading to artifacts that can lead to misleading conclusions. In present study, it was performed in vitro assays with two aquatic species: the zebrafish Danio rerio and the polychaete Laeonereis acuta to evaluate the potential interference capacity of single-wall carbon nanotubes (SWCNT) in a fluorometric method (TBARS assay) to measure lipid peroxidation. Obtained results indicated that gills and brain of zebrafish presented a lowered fluorescence only at extremely high concentrations (50 and 500mg/L). Determinations in anterior, middle, and posterior body regions of L. acuta showed a quite different pattern: high fluorescence at low SWCNT concentrations (0.5mg/L) and lowering at the highest (500mg/L). To eliminate matrix effect of biological samples, tests employing the standard for TBARS assay, 1,3,3-tetramethoxipropane, were run and the results showed again higher fluorescence values at low concentrations (0.5-5mg SWCNT/L), a technique artifact that could lead to misleading conclusions since higher fluorescence values implicate higher TBARS concentration, implying oxidative stress. Using the colorimetric FOX assay with cumene hydroperoxide as standard presented remarkable better results since no artifacts were observed in the same SWCNT concentration range that employed with the TBARS technique. Copyright © 2017 Elsevier Inc. All rights reserved.
Wesolowski, E.A.; Nelson, R.A.
1987-01-01
As part of the Sour is River water-quality assessment, traveltime, longitudinal-dispersion, and reaeration measurements were made during September 1983 on segments of the 186-mile reach of the Sour is River from Lake Darling Dam to the J. Clark Salyer National Wildlife Refuge. The primary objective was to determine traveltime, longitudinal-dispersion, and reaeration coefficients during low flow. Streamflow in the reach ranged from 10.5 to 47.0 cubic feet per second during the measurement period.On the basis of channel and hydraulic characteristics, the 186-mile reach was subdivided into five subreaches that ranged from 18 to 55 river miles in length. Within each subreach, representative test reaches that ranged from 5.0 to 9.1 river miles in length were selected for tracer injection and sample collection. Standard fluorometric techniques were used to measure traveltime and longitudinal dispersion, and a modified tracer technique that used ethylene and propane gas was used to measure reaeration. Mean test-reach velocities ranged from 0.05 to 0.30 foot per second, longitudinal-dispersion coefficients ranged from 4.2 to 61 square feet per second, and reaeration coefficients based on propane ranged from 0.39 to 1.66 per day. Predictive reaeration coefficients obtained from 18 equations (8 semiempirical and 10 empirical) were compared with each measured reaeration coefficient by use of an error-of-estimate analysis. The predictive reaeration coefficients ranged from 0.0008 to 3.4 per day. A semiempirical equation that produced coefficients most similar to the measured coefficients had the smallest absolute error of estimate (0.35). The smallest absolute error of estimate for the empirical equations was 0.41.
Pullar, Juliet M.; Carr, Anitra C.
2018-01-01
Vitamin C (ascorbate) is the major water-soluble antioxidant in plasma and its oxidation to dehydroascorbic acid (DHA) has been proposed as a marker of oxidative stress in vivo. However, controversy exists in the literature around the amount of DHA detected in blood samples collected from various patient cohorts. In this study, we report on DHA concentrations in a selection of different clinical cohorts (diabetes, pneumonia, cancer, and critically ill). All clinical samples were collected into EDTA anticoagulant tubes and processed at 4 °C prior to storage at −80 °C for subsequent analysis by HPLC with electrochemical detection. We also investigated the effects of different handling and processing conditions on short-term and long-term ascorbate and DHA stability in vitro and in whole blood and plasma samples. These conditions included metal chelation, anticoagulants (EDTA and heparin), and processing temperatures (ice, 4 °C and room temperature). Analysis of our clinical cohorts indicated very low to negligible DHA concentrations. Samples exhibiting haemolysis contained significantly higher concentrations of DHA. Metal chelation inhibited oxidation of vitamin C in vitro, confirming the involvement of contaminating metal ions. Although EDTA is an effective metal chelator, complexes with transition metal ions are still redox active, thus its use as an anticoagulant can facilitate metal ion-dependent oxidation of vitamin C in whole blood and plasma. Handling and processing blood samples on ice (or at 4 °C) delayed oxidation of vitamin C by a number of hours. A review of the literature regarding DHA concentrations in clinical cohorts highlighted the fact that studies using colourimetric or fluorometric assays reported significantly higher concentrations of DHA compared to those using HPLC with electrochemical detection. In conclusion, careful handling and processing of samples, combined with appropriate analysis, is crucial for accurate determination of ascorbate and DHA in clinical samples. PMID:29439480
Mohammed, Fatima H; Khajah, Maitham A; Yang, Ming; Brackenbury, William J; Luqmani, Yunus A
2016-01-01
Voltage-gated Na+ channels (VGSCs) are membrane proteins which are normally expressed in excitable cells but have also been detected in cancer cells, where they are thought to be involved in malignancy progression. In this study we examined the ion current and expression profile of VGSC (Nav1.5) in estrogen receptor (ER)-positive (MCF-7) and silenced (pII) breast cancer cells and its possible influence on their proliferation, motility and invasion. VGSC currents were analysed by whole cell patch clamp recording. Nav1.5 expression and localization, in response to EGF stimulation, was examined by western blotting and immunofluorescence respectively. Cell invasion (under-agarose and Matrigel assays), motility (wound healing assay) and proliferation (MTT assay) were assessed in pII cells in response to VGSC blockers, phenytoin (PHT) and tetrodotoxin (TTX), or by siRNA knockdown of Nav1.5. The effect of PHT and TTX on modulating EGF-induced phosphorylation of Akt and ERK1/2 was determined by western blotting. Total matrix metalloproteinase (MMP) was determined using a fluorometric-based activity assay. The level of various human proteases was detected by using proteome profiler array kit. VGSC currents were detected in pII cells, but were absent in MCF-7. Nav1.5 showed cytoplasmic and perinuclear expression in both MCF-7 and pII cells, with enhanced expression upon EGF stimulation. Treatment of pII cells with PHT, TTX or siRNA significantly reduced invasion towards serum components and EGF, in part through reduction of P-ERK1/2 and proteases such as cathepsin E, kallikrein-10 and MMP-7, as well as total MMP activity. At high concentrations, PHT inhibited motility while TTX reduced cell proliferation. Pharmacological or genetic blockade of Nav1.5 may serve as a potential anti-metastatic therapy for breast cancer.
Lin, Fan; Chandrasekaran, Gayathri; de Gooijer, Mark C; Beijnen, Jos H; van Tellingen, Olaf
2012-07-15
NVP-BEZ235 is a novel dual inhibitor of PI3K/mTOR and currently undergoing phase I/II clinical trials for advanced solid tumors. We developed a sensitive and selective reversed-phase high-performance liquid chromatographic (HPLC) assay with fluorometric detection for quantification of NVP-BEZ235 in biological matrices. Liquid-liquid extraction with tert-butyl methyl ether was used for sample pre-treatment, yielding a recovery of >84%. Chromatographic separation of NVP-BEZ235 and the internal standard (IS) NVP-BBD130 was achieved on a GraceSmart C-18 column by isocratic elution with a mobile phase which consisted of acetonitrile, methanol, and milliQ water adjusted with acetic acid to pH 3.7 (20:36:44, v/v/v). Fluorescence detection using excitation and emission wavelengths of 270 and 425 nm, respectively, provided a selectivity and sensitivity allowing quantification down to 1 ng/ml in human plasma and linear calibration curves within a range of 1-1000 ng/ml. The assay was validated for human plasma, mouse plasma and a range of tissues. The accuracy, within-day and between-day precision for all matrices, was within the generally accepted 15% range. NVP-BEZ235 was stable for 72 h in pretreated samples in reconstitution mixture (acetonitrile-water (30:70, v/v)), but unstable in mouse tissue homogenates upon repeated freeze-thaw cycles or long term storage (≥24 h) at room temperature. A pilot pharmacokinetic study in mice demonstrated the applicability of this method for pharmacokinetic purposes. Overall, this assay is suitable for the pharmacokinetic studies of NVP-BEZ235 in mice and in human plasma. Copyright © 2012 Elsevier B.V. All rights reserved.
Clauwaert, K M; Van Bocxlaer, J F; De Letter, E A; Van Calenbergh, S; Lambert, W E; De Leenheer, A P
2000-12-01
The popular designer drugs 3, 4-methylenedioxymethamphetamine (MDMA) and 3, 4-methylenedioxyethylamphetamine (MDEA) can be determined in serum, whole blood, and urine, but also in vitreous humor. The latter matrix is interesting when dealing with decomposed bodies in a toxicological setting. After extraction, chromatographic separation was achieved on a narrow-bore C(18) column by gradient elution with fluorometric detection; results were confirmed by liquid chromatography-tandem mass spectrometry (LC-MS/MS). The method was linear over the range of 2-1000 microg/L for whole blood, serum, and vitreous humor, and 0.1-5 mg/L for urine. Extraction recoveries were >70%, imprecision (CV) was 2.5-19%, and analytical recoveries were 95.5-104.4%. The limit of detection (LOD) and the limit of quantification (LOQ) were 0.8 and 2 microg/L, respectively, for whole blood, serum, and vitreous humor, and 2.5 microg/L and 0.1 mg/L, respectively, for urine. Excellent correlations between the quantitative LC-fluorescence and LC-MS/MS results were obtained. We found the following concentrations in a thanatochemical distribution study in rabbits: in serum, 5.3-685 microg/L for MDMA and from the LOQ to 14.5 microg/L for 3, 4-methylenedioxyamphetamine (MDA); in whole blood, 19.7-710 microg/L for MDMA and from the LOQ to 17.8 microg/L for MDA; in vitreous humor, 12.1-97.8 microg/L for MDMA and from the LOQ to 3.86 microg/L for MDA. In routine toxicological urine samples, concentrations ranged from LOQ to 14.62 mg/L for MDA, from LOQ to 157 mg/L for MDMA, and from LOQ to 32.54 mg/L for MDEA. The HPLC method described is sensitive, specific, and suitable for the determination of MDMA, MDEA, and MDA in whole blood, serum, vitreous humor, and urine.
Tsuji, A; Sato, Y; Hirano, M; Suga, T; Koshimoto, H; Taguchi, T; Ohsuka, S
2001-01-01
We previously showed that a specific kind of mRNA (c-fos) was detected in a living cell under a microscope by introducing two fluorescently labeled oligodeoxynucleotides, each labeled with donor or acceptor, into the cytoplasm, making them hybridize to adjacent locations on c-fos mRNA, and taking images of fluorescence resonance energy transfer (FRET) (A. Tsuji, H. Koshimoto, Y. Sato, M. Hirano. Y. Sei-Iida, S. Kondo, and K. Ishibashi, 2000, Biophys. J. 78:3260-3274). On the formed hybrid, the distance between donor and acceptor becomes close and FRET occurs. To observe small numbers of mRNA in living cells using this method, it is required that FRET fluorescence of hybrid must be distinguished from fluorescence of excess amounts of non-hybridizing probes and from cell autofluorescence. To meet these requirements, we developed a time-resolved method using acceptor fluorescence decays. When a combination of a donor having longer fluorescence lifetime and an acceptor having shorter lifetime is used, the measured fluorescence decays of acceptors under FRET becomes slower than the acceptor fluorescence decay with direct excitation. A combination of Bodipy493/503 and Cy5 was selected as donor and acceptor. When the formed hybrid had a configuration where the target RNA has no single-strand part between the two fluorophores, the acceptor fluorescence of hybrid had a sufficiently longer delay to detect fluorescence of hybrid in the presence of excess amounts of non-hybridizing probes. Spatial separation of 10-12 bases between two fluorophores on the hybrid is also required. The decay is also much slower than cell autofluorescence, and smaller numbers of hybrid were detected with less interference of cell autofluorescence in the cytoplasm of living cells under a time-resolved fluorescence microscope with a time-gated function equipped camera. The present method will be useful when observing induced expressions of mRNA in living cells. PMID:11423432
Determination of dissolved nitric oxide in coastal waters of the Yellow Sea off Qingdao
NASA Astrophysics Data System (ADS)
Liu, Chun-Ying; Feng, Wei-Hua; Tian, Ye; Yang, Gui-Peng; Li, Pei-Feng; Bange, Hermann W.
2017-08-01
We developed a new method for the determination of dissolved nitric oxide (NO) in discrete seawater samples based on the combination of a purge-and-trap setup and a fluorometric detection of NO. 2,3-diaminonaphthalene (DAN) reacts with NO in seawater to form the highly fluorescent 2,3-naphthotriazole (NAT). The fluorescence intensity was linear for NO concentrations in the range from 0.14 to 19 nmol L-1. We determined a detection limit of 0.068 nmol L-1, an average recovery coefficient of 83.8 % (80.2-90.0 %), and a relative standard deviation of ±7.2 %. With our method we determined for the first time the temporal and spatial distributions of NO surface concentrations in coastal waters of the Yellow Sea off Qingdao and in Jiaozhou Bay during a cruise in November 2009. The concentrations of NO varied from below the detection limit to 0.50 nmol L-1 with an average of 0.26 ± 0.14 nmol L-1. NO surface concentrations were generally enhanced significantly during daytime, implying that NO formation processes such as NO2- photolysis are much higher during daytime than chemical NO consumption, which, in turn, lead to a significant decrease in NO concentrations during nighttime. In general, NO surface concentrations and measured NO production rates were higher compared to previously reported measurements. This might be caused by the high NO2- surface concentrations encountered during the cruise. Moreover, additional measurements of NO production rates implied that the occurrence of particles and a temperature increase can enhance NO production rates. With the method introduced here, we have a reliable and comparably easy to use method at hand to measure oceanic NO surface concentrations, which can be used to decipher both its temporal and spatial distributions as well as its biogeochemical pathways in the oceans.
Orywal, Karolina; Jelski, Wojciech; Werel, Tadeusz; Szmitkowski, Maciej
2018-01-02
The aim of this study was to determine the differences in the activity of Alcohol Dehydrogenase (ADH) isoenzymes and Aldehyde Dehydrogenase (ALDH) in normal and cancerous bladder cells. Class III, IV of ADH and total ADH activity were measured by the photometric method and class I, II ADH and ALDH activity by the fluorometric method. Significantly higher total activity of ADH was found in both, low-grade and high-grade bladder cancer, in comparison to healthy tissues. The increased activity of total ADH in bladder cancer cells may be the cause of metabolic disorders in cancer cells, which may intensify carcinogenesis.
Frank, Juliane; Gündel, Daniel; Drescher, Simon; Thews, Oliver; Mäder, Karsten
2015-12-01
Electron paramagnetic resonance (EPR) oximetry is a technique which allows accurate and repeatable oxygen measurements. We encapsulated a highly oxygen sensitive particulate EPR spin probe into microparticles to improve its dispersibility and, hence, facilitate the administration. These biocompatible, non-toxic microspheres contained 5-10 % (w/w) spin probe and had an oxygen sensitivity of 0.60 ± 0.01 µT/mmHg. To evaluate the performance of the microparticles as oxygen sensors, they were co-implanted with syngeneic tumor cells in 2 different rat strains. Thus, tissue injury was avoided and the microparticles were distributed all over the tumor tissue. Dynamic changes of the intratumoral oxygen partial pressure during inhalation of 8 %, 21 %, or 100 % oxygen were monitored in vivo by EPR spectroscopy and quantified. Values were verified in vivo by invasive fluorometric measurements using Oxylite probes and ex vivo by pimonidazole adduct accumulation. There were no hints that the tumor physiology or tissue oxygenation had been altered by the microparticles. Hence, these microprobes offer great potential as oxygen sensors in preclinical research, not only for EPR spectroscopy but also for EPR imaging. For instance, the assessment of tissue oxygenation during therapeutic interventions might help understanding pathophysiological processes and lead to an individualized treatment planning or the use of formulations with hypoxia triggered release of active agents. Copyright © 2015 Elsevier Inc. All rights reserved.
The progress in the cholinesterase quantification methods.
Holas, Ondrej; Musilek, Kamil; Pohanka, Miroslav; Kuca, Kamil
2012-12-01
Determination of acetylcholinesterase and butyrylcholinesterase activity has become an important tool in drug design and discovery as well as in medicine and toxicology. There are a large number of compounds that are able to modulate cholinesterase activity. These compounds can be used for pharmacological management of various disorders (e.g., Alzheimer's disease, myasthenia Gravis). Moreover, organophosphate poisoning is frequently diagnosed via a cholinesterase activity assay. This broad variety of methods has been developed over the past decades for cholinesterase activity quantification. This review provides a summary of the methods that are based on specific properties of cholinesterases and their interactions with native or artificial substrates. The authors also aim to provide an overview of different techniques used for the determination of quantitative cholinesterase activity. Specifically, the authors describe and discuss the manometric, potentiometric, titrimetric, photometric, fluorometric, and radioisotopic methods. Existing methods are able to cover most of the problems that arise during cholinesterase activity determination. Colorimetry according to Ellman has proved to be the most useful and versatile approach. It may be used in various protocols for the determination of pesticide or nerve agent exposure or for the development of new drugs. Its possible improvement lies in optimization of hemoglobin-rich samples. The progress of the most common methods (including Ellman) depends on miniaturization and modern physical platforms (e.g., optical fibers, chip methods, or nanotechnologies).
Bragulat, M Rosa; Eustaquio, Alba; Cabañes, F Javier
2017-01-01
Ochratoxin A (OTA) is a potent nephrotoxin and carcinogen which is found in a wide variety of common foods and beverages and it is produced by several species of Aspergillus and Penicillium. Ochratoxin α (OTα), a major metabolite of OTA, has also been reported to occur in cultures of OTA-producing species. However there is some controversial about the participation of OTα in the biosynthesis of OTA, mainly because its biosynthesis pathway has not yet been completely characterized. Aspergillus carbonarius is the main responsible source of ochratoxin A (OTA) in food commodities such as wine, grapes or dried vine fruits from main viticultural regions worldwide. However, little is known about the presence of OTα in isolates of A. carbonarius. In this study we evaluated the effects of temperature and incubation time on OTα production by both OTA and non-OTA-producing strains of A. carbonarius. OTA and OTα were detected on the basis of HPLC fluorometric response compared with that of their standards and confirmed by HPLC-MS in selected samples. The non-OTA-producing strains did produce neither OTA nor OTα at any of the conditions tested. The OTA-producing strains studied were able to produce both OTA and OTα in most of the conditions tested. In general, higher amounts of OTA than OTα were produced, but a positive correlation in the production of these two metabolites was detected. The lack of production of both OTA and OTα in the non-OTA-producing strains could be caused by the presence of silent genes or by mutations in functional or regulatory genes involved in OTA production.
NASA Astrophysics Data System (ADS)
Kundu, Anu; Anthony, Savarimuthu Philip
2018-01-01
Triphenyl amine based chemosensors, (2-(((2-(9H-carbazol-9-yl)phenyl)imino)methyl)-5-(diphenylamino)phenol (ortho-CPDP) and 2-(((4-(9H-carbazol-9-yl)phenyl)imino)methyl)-5-(diphenylamino)phenol (para-CPDP), showed solvent and isomerism dependent selective coloro/fluorometric sensing of multiple metal ions (Fe3 +, Al3 + and Zn2 +) with distinguishable responses. In CH3CN, ortho and para-CPDP selectively produced yellow color upon addition of Al3 + and Fe3 + that was slowly disappeared. The yellow color of ortho and para-CPDP in DMF was decolourised selectively by adding Al3 + and Fe3 +. Both ortho and para-CPDP in CH3CN showed nearly similar rate of decolourization for Fe3 + and Al3 +. However, the rate of decolourization of ortho and para-CPDP in DMF was different for Fe3 + (10 μM, 8 min) and Al3 + (5 × 10- 4 M, 40 min) ions. The limit of detection of para-CPDP for Fe3 + is 10 μM and Al3 + 500 μM. The mechanistic studies revealed the imine hydrolysis of ortho and para-CPDP in presence of Lewis acidic Fe3 + and Al3 +. The reactivity based sensing lead to high selectivity for Al3 + and Fe3 + ions. Further, para-CPDP exhibited selective fluorescence turn-on for Zn2 + in DMF (λmax = 513 nm) and detection limit of 6.0 μM. Thus, reactive chemosensors, ortho and para-CPDP, exhibited selective and distinguishable colorimetric sensing of Fe3 + and Al3 + ions and isomerism and solvent dependent fluorescence sensing of Zn2 +.
Stone, Orrin J; Biette, Kelly M; Murphy, Patrick J M
2014-01-01
Hydrophobic interaction chromatography (HIC) most commonly requires experimental determination (i.e., scouting) in order to select an optimal chromatographic medium for purifying a given target protein. Neither a two-step purification of untagged green fluorescent protein (GFP) from crude bacterial lysate using sequential HIC and size exclusion chromatography (SEC), nor HIC column scouting elution profiles of GFP, have been previously reported. Bacterial lysate expressing recombinant GFP was sequentially adsorbed to commercially available HIC columns containing butyl, octyl, and phenyl-based HIC ligands coupled to matrices of varying bead size. The lysate was fractionated using a linear ammonium phosphate salt gradient at constant pH. Collected HIC eluate fractions containing retained GFP were then pooled and further purified using high-resolution preparative SEC. Significant differences in presumptive GFP elution profiles were observed using in-line absorption spectrophotometry (A395) and post-run fluorimetry. SDS-PAGE and western blot demonstrated that fluorometric detection was the more accurate indicator of GFP elution in both HIC and SEC purification steps. Comparison of composite HIC column scouting data indicated that a phenyl ligand coupled to a 34 µm matrix produced the highest degree of target protein capture and separation. Conducting two-step protein purification using the preferred HIC medium followed by SEC resulted in a final, concentrated product with >98% protein purity. In-line absorbance spectrophotometry was not as precise of an indicator of GFP elution as post-run fluorimetry. These findings demonstrate the importance of utilizing a combination of detection methods when evaluating purification strategies. GFP is a well-characterized model protein, used heavily in educational settings and by researchers with limited protein purification experience, and the data and strategies presented here may aid in development other of HIC-compatible protein purification schemes.
Bragulat, M. Rosa; Eustaquio, Alba
2017-01-01
Ochratoxin A (OTA) is a potent nephrotoxin and carcinogen which is found in a wide variety of common foods and beverages and it is produced by several species of Aspergillus and Penicillium. Ochratoxin α (OTα), a major metabolite of OTA, has also been reported to occur in cultures of OTA-producing species. However there is some controversial about the participation of OTα in the biosynthesis of OTA, mainly because its biosynthesis pathway has not yet been completely characterized. Aspergillus carbonarius is the main responsible source of ochratoxin A (OTA) in food commodities such as wine, grapes or dried vine fruits from main viticultural regions worldwide. However, little is known about the presence of OTα in isolates of A. carbonarius. In this study we evaluated the effects of temperature and incubation time on OTα production by both OTA and non-OTA-producing strains of A. carbonarius. OTA and OTα were detected on the basis of HPLC fluorometric response compared with that of their standards and confirmed by HPLC-MS in selected samples. The non-OTA-producing strains did produce neither OTA nor OTα at any of the conditions tested. The OTA-producing strains studied were able to produce both OTA and OTα in most of the conditions tested. In general, higher amounts of OTA than OTα were produced, but a positive correlation in the production of these two metabolites was detected. The lack of production of both OTA and OTα in the non-OTA-producing strains could be caused by the presence of silent genes or by mutations in functional or regulatory genes involved in OTA production. PMID:29016677
Xu, Li; Ye, Rongjian; Zheng, Yusheng; Wang, Zhekui; Zhou, Peng; Lin, Yongjun; Li, Dongdong
2010-09-01
As one of the key tropical crops, coconut (Cocos nucifera L.) is a member of the monocotyledonous family Aracaceae (Palmaceae). In this study, we amplified the upstream region of an endosperm-specific expression gene, Lysophosphatidyl acyltransferase (LPAAT), from the coconut genomic DNA by chromosome walking. In this sequence, we found several types of promoter-related elements including TATA-box, CAAT-box and Skn1-motif. In order to further examine its function, three different 5'-deletion fragments were inserted into pBI101.3, a plant expression vector harboring the LPAAT upstream sequence, leading to pBI101.3-L1, pBI101.3-L2 and pBI101.3-L3, respectively. We obtained transgenic plants of rice by Agrobacterium-mediated callus transformation and plant regeneration and detected the expression of gus gene by histochemical staining and fluorometric determination. We found that gus gene driven by the three deletion fragments was specifically expressed in the endosperm of rice seeds, but not in the empty vector of pBI101.3 and other tissues. The highest expression level of GUS was at 15 DAF in pBI101.3-L3 and pBI101.3-L2 transgenic lines, while the same level was detected at 10 DAF in pBI101.3-L1. The expression driven by the whole fragment was up to 1.76- and 2.8-fold higher than those driven by the -817 bp and -453 bp upstream fragments, and 10.7-fold higher than that driven by the vector without the promoter. Taken together, our results strongly suggest that these promoter fragments from coconut have a significant potential in genetically improving endosperm in main crops.
NASA Astrophysics Data System (ADS)
Choudhury, Faraz Anwar
A high concentration of free radicals is present in many processing plasmas, which affects the processing conditions and the properties of materials exposed to the plasma. Measuring the types and concentrations of free radicals present in the plasma is critical in order to determine their effects on the materials being processed. Current methods for detecting free radicals in a plasma require multiple expensive and bulky instruments, complex setups and often modifications to the plasma reactor. In this work, we present a simple technique that detects reactive-oxygen radicals incident on a surface from a plasma. The measurements are made using a fluorophore dye that is commonly used in biological and cellular systems for assay labeling in liquids. Using fluorometric analysis, it was found that the fluorophore reacts with oxygen radicals incident from the plasma, which is indicated by degradation of its fluorescence. As plasma power was increased, the quenching of the fluorescence significantly increased. Both immobilized and non-immobilized fluorophore dyes were used and the results indicate that both states function effectively under vacuum conditions. Using radical-sensitive dyes and free-standing films, the transmission of oxygen radicals through silicon nitride and silicon dioxide dielectric films is measured and their absorption lengths are determined. The absorption lengths were found to be 33, 37 and 40 nm for 15, 30 and 45-minute oxygen plasma exposures respectively. FTIR and XRR measurements show that a silicon oxynitride-like layer forms on the surface of the film which has a lower density than silicon nitride. The increase in absorption length with plasma-exposure time is attributed to the formation of the surface layer. In silicon dioxide films, the absorption length of oxygen radicals was found to be 70 nm after 20 minutes of plasma exposure. After 30 minutes of plasma exposure under the same conditions, the absorption length was reduced to 66 nm. XRR and FTIR measurements both reveal that the oxygen plasma exposure leads to surface oxidation of the silicon dioxide film and the formation of a denser surface layer which restricts the transmission of the radicals through the film. It was found that the extent of modification of the film partially depends on the radical dose. The calculated enthalpies of the reactions show that they are all exothermic reactions, however, the radicals need enough energy to overcome the activation energy for the reaction to take place.
Palsule, Vrushalee V.; Yeo, Jiyoun; Shepherd, Brian S.; Crawford, Erin L.; Stepien, Carol A.
2013-01-01
Viral Hemorrhagic Septicemia virus (VHSv) is one of the world's most serious fish pathogens, infecting >80 marine, freshwater, and estuarine fish species from Eurasia and North America. A novel and especially virulent strain – IVb – appeared in the Great Lakes in 2003, has killed many game fish species in a series of outbreaks in subsequent years, and shut down interstate transport of baitfish. Cell culture is the diagnostic method approved by the USDA-APHIS, which takes a month or longer, lacks sensitivity, and does not quantify the amount of virus. We thus present a novel, easy, rapid, and highly sensitive real-time quantitative reverse transcription PCR (qRT-PCR) assay that incorporates synthetic competitive template internal standards for quality control to circumvent false negative results. Results demonstrate high signal-to-analyte response (slope = 1.00±0.02) and a linear dynamic range that spans seven orders of magnitude (R2 = 0.99), ranging from 6 to 6,000,000 molecules. Infected fishes are found to harbor levels of virus that range to 1,200,000 VHSv molecules/106 actb1 molecules with 1,000 being a rough cut-off for clinical signs of disease. This new assay is rapid, inexpensive, and has significantly greater accuracy than other published qRT-PCR tests and traditional cell culture diagnostics. PMID:23977162
Edaravone Protect against Retinal Damage in Streptozotocin-Induced Diabetic Mice
Liu, Xiaoyi; Chen, Xi; Xie, Ping; Yuan, Songtao; Zhang, Weiwei; Lin, Xiaojun; Liu, Qinghuai
2014-01-01
Edaravone (3-methyl-1-phenyl-2-pyrazolin-5-one), a free radical scavenger, is used for the clinical treatment of retinal injury. In this study, we investigated the protective effects of edaravone against diabetic retinal damage in the mouse. Diabetic retinopathy in the mouse was induced by injection of streptozotocin. Edaravone was given once-daily and was intraperitoneally (i.p.) treated at a dose of 3 mg/kg from streptozotocin injection to 4 weeks after onset of diabetes. Retinal ganglion cells (RGCs) damage was evaluated by recording the pattern electroretinogram (ERG). RGCs damage was also detected by Terminal deoxynucleotidyl transferase dUTP nick end labeling (TUNEL) staining, and the levels of reactive oxygen species (ROS) were determined fluorometrically. The expressions of phosporylated-ERK1/2, BDNF, and caspase-3 were determined by Western blot analysis. Retinal levels of ROS, phosphorylated ERK1/2, and cleaved caspase-3 were significantly increased, whereas the expression of BDNF was significantly decreased in the retinas of diabetic mice, compared to nondiabetic mice. Administration of edaravone significantly attenuated diabetes induced RGCs death, upregulation of ROS, ERK1/2 phosphorylation, and cleaved caspase-3 and downregulation of BDNF. These findings suggest that oxidative stress plays a pivotal role in diabetic retinal damage and that systemic administration of edaravone may slow the progression of retinal neuropathy induced by diabetes. PMID:24897298
Phosphatase activities as biosignatures of extant life
NASA Astrophysics Data System (ADS)
Kobayashi, K.; Itoh, Y.; Edazawa, Y.; Moroi, A.; Takano, Y.
It has been recognized that terrestrial biosphere expands to such extreme environments as deep subsurface lithosphere high temperature hot springs and stratosphere Possible extraterrestrial biospheres in Mars Europa and Titan are being discussed Many biosignatures or biomarkers have been proposed to detect microbial activities in such extreme environments Phosphate esters are essential for the terrestrial life since they are constituents of nucleic acids and cell mebranes Thus all the terrestrial organisms have phosphatases that are enzymes catalyzing hydrolysis of phosphate esters We analyzed phosphatase activities in the samples obtained in extreme environments such as submarine hydrothermal systems and discussed whether they can be used as biosignatures for extant life Core samples and chimney samples were collected at the Suiyo Seamount Izu-Bonin Arc the Pacific Ocean in 2001 and 2002 and in South Mariana hydrothermal systems the Pacific Oceanas in 2003 both in a part of the Archaean Park Project Phosphatase activity in solid rock samples was measured spectrometrically by using 25 mM p-nitrophenyl phosphate pH 8 0 or pH 6 5 as a substrate as follows Pulverized samples were incuvated with substrate solution for an hour and then production rate of p-nitrophenol was calculated with absorbance at 410 nm Phosphatase activity in extracts was measured fluorometrically by using 4-methylumberyferryl phosphate as a substrate Concentration of amino acids and their enantiomeric ratio were determined by HPLC after HF digestion of the
Pulmonary serotonin and histamine in experimental asbestosis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Keith, I.M.; Day, R.; Lemaire, S.
1986-03-01
Adult male Wistar rats were treated once with tracheal instillation of 5 mg Crysotile B asbestos fibers in 0.5 ml saline under ketamine/xylaxine anesthesia. Control rats (n = 37) received 0.5 ml saline. Test and control rats were killed at 7 and 14 d., and 1, 3 and 6 mo. post instillation. Serotonin (5-HT) was quantitated in lung tissue homogenate from all rats using HPLC and electrochemical detection. Among rats killed at 1, 3 and 6 mo., lung tissue histamine-o-phthaldialdehyde complex was quantitated using reverse phase HPLC coupled to a fluorometric detector. Furthermore, 5-HT was quantitated in the cytoplasm ofmore » grouped (NEB) and individual (NEC) neuroendocrine cells and in mast cells using formaldehyde-vapor-induced fluorescence and microspectrofluorometry, and mast cell numbers were determined. Test rats had higher pulmonary 5-HT and histamine levels than controls at 1, 3 and 6 mo. Test rats also had higher cellular 5-HT compared to controls in NEB's at 1 mo., but not in NECs, and tended to have higher 5-HT-levels in mast cells at 6 mo. Mast cell numbers were higher among tests at 1 and 3 mo. The authors results suggest that NEBs may contribute to the early asbestos induced rise in 5-HT, and that the major source of 5-HT and histamine is from the increased numbers of mast cells.« less
Pierce, Lindsey R; Willey, James C; Palsule, Vrushalee V; Yeo, Jiyoun; Shepherd, Brian S; Crawford, Erin L; Stepien, Carol A
2013-01-01
Viral Hemorrhagic Septicemia virus (VHSv) is one of the world's most serious fish pathogens, infecting >80 marine, freshwater, and estuarine fish species from Eurasia and North America. A novel and especially virulent strain - IVb - appeared in the Great Lakes in 2003, has killed many game fish species in a series of outbreaks in subsequent years, and shut down interstate transport of baitfish. Cell culture is the diagnostic method approved by the USDA-APHIS, which takes a month or longer, lacks sensitivity, and does not quantify the amount of virus. We thus present a novel, easy, rapid, and highly sensitive real-time quantitative reverse transcription PCR (qRT-PCR) assay that incorporates synthetic competitive template internal standards for quality control to circumvent false negative results. Results demonstrate high signal-to-analyte response (slope = 1.00±0.02) and a linear dynamic range that spans seven orders of magnitude (R(2) = 0.99), ranging from 6 to 6,000,000 molecules. Infected fishes are found to harbor levels of virus that range to 1,200,000 VHSv molecules/10(6) actb1 molecules with 1,000 being a rough cut-off for clinical signs of disease. This new assay is rapid, inexpensive, and has significantly greater accuracy than other published qRT-PCR tests and traditional cell culture diagnostics.
Edaravone protect against retinal damage in streptozotocin-induced diabetic mice.
Yuan, Dongqing; Xu, Yidan; Hang, Hui; Liu, Xiaoyi; Chen, Xi; Xie, Ping; Yuan, Songtao; Zhang, Weiwei; Lin, Xiaojun; Liu, Qinghuai
2014-01-01
Edaravone (3-methyl-1-phenyl-2-pyrazolin-5-one), a free radical scavenger, is used for the clinical treatment of retinal injury. In this study, we investigated the protective effects of edaravone against diabetic retinal damage in the mouse. Diabetic retinopathy in the mouse was induced by injection of streptozotocin. Edaravone was given once-daily and was intraperitoneally (i.p.) treated at a dose of 3 mg/kg from streptozotocin injection to 4 weeks after onset of diabetes. Retinal ganglion cells (RGCs) damage was evaluated by recording the pattern electroretinogram (ERG). RGCs damage was also detected by Terminal deoxynucleotidyl transferase dUTP nick end labeling (TUNEL) staining, and the levels of reactive oxygen species (ROS) were determined fluorometrically. The expressions of phosporylated-ERK1/2, BDNF, and caspase-3 were determined by Western blot analysis. Retinal levels of ROS, phosphorylated ERK1/2, and cleaved caspase-3 were significantly increased, whereas the expression of BDNF was significantly decreased in the retinas of diabetic mice, compared to nondiabetic mice. Administration of edaravone significantly attenuated diabetes induced RGCs death, upregulation of ROS, ERK1/2 phosphorylation, and cleaved caspase-3 and downregulation of BDNF. These findings suggest that oxidative stress plays a pivotal role in diabetic retinal damage and that systemic administration of edaravone may slow the progression of retinal neuropathy induced by diabetes.
Liu, Xiaojie; Lin, Bixia; Yu, Ying; Cao, Yujuan; Guo, Manli
2018-04-02
A multifunctional fluorescent probe is synthesized for the determination of adenosine 5'-triphosphate (ATP). The 6-carboxyfluorescein-labeled aptamer (FAM-aptamer) was bound to the surface of magnetite nanoparticles coated with polydopamine (Fe 3 O 4 @PDA) by π-π stacking interaction to form the multifunctional probe. The probe has three functions including recognition, magnetic separation, and yielding a fluorescent signal. In the presence of ATP, FAM-aptamer on the surface of the probe binds to ATP and returns to the solution. Thus, the fluorescence of the supernatant is enhanced and can be related to the concentration of ATP. Fluorescence intensities were measured at excitation/emission wavelengths of 494/526 nm. Response is linear in the 0.1-100 μM ATP concentration range, and the detection limit is 89 nM. The probe was applied to the quantitation of ATP in spiked human urine and serum samples, with recoveries ranging between 94.8 and 102%. Graphical abstract A multifunctional fluorescent probe based on the use of FAM-aptamer and Fe 3 O 4 @PDA is described for the determination of ATP in spiked human urine and serum samples. FAM-aptamer: 6-carboxyfluorescein-labeled aptamer; Fe 3 O 4 @PDA: magnetite nanoparticles coated with polydopamine. ATP: adenosine 5'-triphosphate.
Zhao, Wenjie; Yang, Liu; He, Lijun; Zhang, Shusheng
2016-08-10
On the basis of the definite retention mechanism proven by the stationary phase for high-performance liquid chromatography, tetraazacalix[2]arene[2]triazine featuring multiple recognition sites was assessed as a solid-phase extraction (SPE) selector. The applicability of its silica support was used for the extraction of trace amounts of polycyclic aromatic hydrocarbons (PAHs) and Cu(2+) in aqueous samples, followed by high-performance liquid chromatography fluorometric and graphite furnace atomic absorption spectrometric determination. On the basis of the π-π interaction with PAHs and the chelating interaction with Cu(2+), the simultaneous extraction of PAHs and Cu(2+) and stepwise elution through tuning the eluent were successfully achieved, respectively. The SPE conditions affecting the extraction efficiency were optimized, including type and concentration of organic modifier, sample solution pH, flow rate, and volume. As a result of the special adsorption and desorption mechanism, high extraction efficiency was achieved with relative recoveries of 94.3-102.4% and relative standard deviations of less than 10.5%. The limits of detection were obtained with 0.4-3.1 ng L(-1) for PAHs and 15 ng L(-1) for Cu(2+), respectively. The method was applied to the analyses of PAHs and Cu(2+) in Xiliu Lake water samples collected in Zhengzhou, China.
Li, Huiyu; Xu, Yuan; Ding, Jie; Zhao, Li; Zhou, Tianyu; Ding, Hong; Chen, Yanhua; Ding, Lan
2018-01-10
Uniform N- and S-co-doped carbon dots (NSCDs) with fluorescence quantum yields of up to 64% were synthesized via a one-step microwave-assisted method. Ammonium citrate and L-cysteine act as precursors, and synthesis is completed in 2.5 min using a 750 W microwave oven to give a 62% yield. The NSCDs show bright blue fluorescence (with excitation/emission peaks at 353/426 nm) and have narrow size distribution. On exposure to levofloxacin (LEV), the emission maximum shifts to 499 nm. This effect was used to design ratiometric (2-wavelength) assays for LEV. The fluorometric method (based on measurement of the fluorescence intensity ratio at 499 and 426 nm) has a detection limit of 5.1 μg·L -1 (3σ/k) and a linear range that extends from 0.01 to 70 mg·L -1 . The method was applied to the determination of LEV in three kinds of spiked water samples and has recoveries in the range from 98.6 to 106.8%. The fluorescent probe described here is highly selective and sensitive. Graphical Abstract Highly luminescent N- and S-co-doped carbon dots were synthesized using AC (ammonium citrate) and Cys (L-cysteine) by microwave-assisted method, and were applied to the visual and ratiometric fluorescence determination of LEV (levofloxacin).
Analyzing B-vitamins in Human Milk: Methodological Approaches.
Hampel, Daniela; Allen, Lindsay H
2016-01-01
According to the World Health Organization (WHO), infants should be exclusively breastfed for the first six months of life. However, there is insufficient information about the concentration of nutrients in human milk. For some nutrients, including B-vitamins, maternal intake affects their concentration in human milk but the extent to which inadequate maternal diets affect milk B-vitamin content is poorly documented. Little is known about infant requirements for B-vitamins; recommendations are generally set as Adequate Intakes (AI) calculated on the basis of the mean volume of milk (0.78 L/day) consumed by infants exclusively fed with human milk from well-nourished mothers during the first six months, and the concentration of each vitamin in milk based on reported values. Methods used for analyzing B-vitamins, commonly microbiological, radioisotope dilution or more recently chromatographic, coupled with UV, fluorometric and MS detection, have rarely been validated for the complex human milk matrix. Thus the validity, accuracy, and sensitivity of analytical methods is important for understanding infant requirements for these nutrients, the maternal intakes needed to support adequate concentrations in breast milk. This review summarizes current knowledge on methods used for analyzing the B-vitamins thiamin, riboflavin, niacin, vitamin B-6 and pantothenic acid, vitamin B-12, folate, biotin, and choline in human milk, their chemical and physical properties, the different forms and changes in concentration during lactation, and the effects of deficiency on the infant.
Zirconium Phosphate Nanoplatelet Potential for Anticancer Drug Delivery Applications.
González, Millie L; Ortiz, Mayra; Hernández, Carmen; Cabán, Jennifer; Rodríguez, Axel; Colón, Jorge L; Báez, Adriana
2016-01-01
Zirconium phosphate (ZrP) nanoplatelets can intercalate anticancer agents via an ion exchange reaction creating an inorganic delivery system with potential for cancer treatment. ZrP delivery of anticancer agents inside tumor cells was explored in vitro. Internalization and cytotoxicity of ZrP nanoplatelets were studied in MCF-7 and MCF-10A cells. DOX-loaded ZrP nanoplatelets (DOX@ZrP) uptake was assessed by confocal (CLSM) and transmission electron microscopy (TEM). Cytotoxicity to MCF-7 and MCF-10A cells was determined by the MTT assay. Reactive Oxy- gen Species (ROS) production was analyzed by fluorometric assay, and cell cycle alterations and induction of apoptosis were analyzed by flow cytometry. ZrP nanoplatelets were localized in the endosomes of MCF-7 cells. DOX and ZrP nanoplatelets were co-internalized into MCF-7 cells as detected by CLSM. While ZrP showed limited toxicity to MCF-7 cells, DOX@ZrP was cytotoxic at an IC₅₀ similar to that of free DOX. Meanwhile, DOX lC₅₀ was significantly lower than the equivalent concentration of DOX@ZrP in MCF-10A cells. ZrP did not induce apoptosis in both cell lines. DOX and DOX@ZrP induced significant oxidative stress in both cell models. Results suggest that ZrP nanoplatelets are promising as carriers of anticancer agents into cancer cells.
La Claire, J W; Manning, S R; Talarski, A E
2015-08-01
A fluorometric assay was developed to semi-quantify co-purified polyketide prymnesins-1 and -2 (PPs) from Prymnesium parvum cultures. Evaluations performed throughout the growth cycle of 5 practical salinity unit (PSU) cultures detected relatively 8-10 × more PPs in the culture medium (exotoxins) than in cells (endotoxins). The [exotoxin] remained stable and relatively low until post-log growth, when they increased significantly. However, on a per-cell basis, [exotoxin] declined throughout log phase and subsequently increased dramatically during late- and post-log phases. The [endotoxin] remained stable until late- and post-log phases, when it achieved its highest level before declining sharply. Shaking cultures of strains from Texas, South Carolina and the United Kingdom displayed dramatically different [exotoxin] during post-log decline. Cultures adapted to 30 PSU had significantly lower [exotoxin] over the course of cultivation than those grown at 5 PSU. Phosphate limitation enhanced [exotoxin] on a per-cell basis, especially in late- and post-log cultures. Media containing streptomycin exhibited a ∼20% increase in [exotoxin] in post-log cultures vs. control treatments, but it had only negligible effects on endotoxin levels. Brefeldin A had minimal effects on [exotoxin], suggesting that the presence of PPs in the medium may be largely derived from cell lysis or some other passive means. Copyright © 2015 Elsevier Ltd. All rights reserved.
Hydrogen peroxide formation during iron deposition in horse spleen ferritin using O2 as an oxidant.
Lindsay, S; Brosnahan, D; Watt, G D
2001-03-20
The reaction of Fe2+ with O2 in the presence of horse spleen ferritin (HoSF) results in deposition of FeOH3 into the hollow interior of HoSF. This reaction was examined at low Fe2+/HoSF ratios (5-100) under saturating air at pH 6.5-8.0 to determine if H2O2 is a product of the iron deposition reaction. Three methods specific for H2O2 detection were used to assess H2O2 formation: (1) a fluorometric method with emission at 590 nm, (2) an optical absorbance method based on the reaction H2O2 + 3I- + 2H+ = I3- + 2H2O monitored at 340 nm for I3- formation, and (3) a differential pulsed electrochemical method that measures O2 and H2O2 concentrations simultaneously. Detection limits of 0.25, 2.5, and 5.0 microM H2O2 were determined for the three methods, respectively. Under constant air-saturation conditions (20% O2) and for a 5-100 Fe2+/HoSF ratio, Fe2+ was oxidized and the resulting Fe3+ was deposited within HoSF but no H2O2 was detected as predicted by the reaction 2Fe2+ + O2 + 6H2O = 2Fe(OH)3 + H2O2 + 4H+. Two other sets of conditions were also examined: one with excess but nonsaturating O2 and another with limiting O2. No H2O2 was detected in either case. The absence of H2O2 formation under these same conditions was confirmed by microcoulometric measurements. Taken together, the results show that under low iron loading conditions (5-100 Fe2+/HoSF ratio), H2O2 is not produced during iron deposition into HoSF using O2 as an oxidant. This conclusion is inconsistent with previous, carefully conducted stoichiometric and kinetic measurements [Xu, B., and Chasteen, N. D. (1991) J. Biol. Chem. 266, 19965], predicting that H2O2 is a quantitative product of the iron deposition reaction with O2 as an oxidant, even though it was not directly detected. Possible explanations for these conflicting results are considered.
Leiro, José M; Piazzon, Carla; Domínguez, Berta; Mallo, Natalia; Lamas, Jesús
2012-05-15
Microsporidia are a large diverse group of intracellular parasites now considered as fungi. They are particularly prevalent in fish and are recognized as important opportunistic parasites in humans. Although the mode of transmission of microsporidia has not been fully clarified, the consumption and manipulation of infected fish may be a risk factor for humans. Comparative analysis of rDNA sequence revealed that the microsporidians used in the present study had 99-100% identity with anglerfish microsporidians of the genus Spraguea and very low identity with microsporidians that infect humans. Microsporidian spores were exposed to different physical and chemical treatments: freezing at -20°C for 24-78 h, heating at 60°C for 5-15 min, microwaving at 700 W, 2.45 GHz for 15-60s, and treatment with ethanol at concentrations of between 1 and 70% for 15 min. The viability of the spores after each treatment was evaluated by two methods: a) haemocytometer counts, measuring the extrusion of the polar filament in control and treated spores, and b) a fluorometric method, testing the membrane integrity by propidium iodide exclusion. The results of both methods were concordant. Spores were inactivated by freezing at -20°C for more than 48 h, by heating to 60°C for 10 min and by microwaving at 750 W, for 20s. Exposure to 70% ethanol for 15 min also inactivated microsporidian spores. The results suggest that both freezing and heating are effective treatments for destroying microsporidian spores in European white anglerfish, and that 70% ethanol could be used by fish processors to disinfect their hands and the utensils used in processing fish. The fluorometric method can be used as an alternative to haemocytometer counts in disinfection studies aimed at establishing strategies for inactivating and reducing the viability and the potential infectivity of microsporidians present in fish or in the environment. Copyright © 2012 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Scaramboni, C.; Crispim, C. P.; Toledo, J. C.; Campos, M. L. A. M.
2018-03-01
This work investigates the effect of public policies related to vehicle emissions on the lower tropospheric concentrations of H2O2 in a typical midsized city in tropical Brazil. The concentrations of H2O2, SO42-, and NO3- in rainwater samples were determined from 2014 to 2017 in the municipality of Ribeirão Preto in São Paulo State. A fluorometric method, based on the formation of a highly fluorescent product (2‧,7‧-dichlorofluorescein, DCF), was adapted and optimized for the measurement of H2O2 in natural water samples including seawater. The method was highly specific, accurate and sensitive (LOD = 2 nmol L-1). Its main advantage compared to others, was that the fluorophore remained stable for at least 48 h, offering a longer time interval in which to perform the analysis and therefore facilitating fieldwork. Concentrations of H2O2 in rainwater ranged from 5.8 to 96 μmol L-1, with VWM of 28.6 ± 1.4 μmol L-1 (n = 77). Solar radiation appeared to have a greater impact on production than on consumption of H2O2. The annual VWM concentrations of H2O2 in rainwater were negatively correlated with sulfate (at pH < 5) and nitrate, suggesting that national policies designed to reduce vehicle emissions of SO2 and NOx resulted in increased atmospheric H2O2 concentrations, impacting the oxidative capacity of the lower troposphere. Biomass burning emissions and photochemical reactions were also found to be important factors affecting the concentration of H2O2 in the atmosphere. This work expands the current records available for the Southern Hemisphere, where there is a considerable paucity of information regarding temporal production and loss of atmospheric H2O2.
Regional analyses of CNS microdialysate glucose and lactate in seizure patients.
Cornford, Eain M; Shamsa, Kamran; Zeitzer, Jamie M; Enriquez, Cathleen M; Wilson, Charles L; Behnke, Eric J; Fried, Itzhak; Engel, Jerome
2002-11-01
To correlate glucose (and lactate) results obtained from microdialysate to recent studies suggesting that glucose transporter activity may be significantly altered in seizures. We used a fluorometric technique to quantify glucose and lactate levels in microdialysates collected from two to four depth electrodes implanted per patient in the temporal and frontal lobes of a series of four patients. Hour-by-hour and day-to-day changes in brain glucose and lactate levels at the same site were recorded. Additionally we compared regional variations in lactate/glucose ratios around the predicted epileptogenic region. Lactate/glucose ratios in the range of 1-2:1 were the most commonly seen. When the lactate/glucose ratio was <1:1, we typically observed a relative increase in local glucose concentration (rather than decreased lactate), suggesting increased transport, perhaps without increased glycolysis. In some sites, lactate/glucose ratios of 3:1-15:1 were seen, suggesting that a circumscribed zone of inhibition of tricarboxylic acid cycle activity may have been locally induced. In these dialysates, collected from probes closer to the epileptogenic region, the large increase in lactate/glucose ratios was a result of both increased lactate and reduced glucose levels. We conclude that regional variations in brain extracellular glucose concentrations may be of greater magnitude than previously believed and become even more accentuated in partial seizure patients. Data from concomitant assays of microdialysate lactate and glucose may aid in understanding cerebral metabolism.
Mull, D.S.; Smoot, J.L.; Liebermann, T.D.
1988-01-01
Because of the vulnerability of karst aquifers to contamination and the need for water managers to know recharge areas and groundwater flow characteristics for springs and wells used for public water supply, qualitative and quantitative dye tracing techniques were used during a groundwater investigation in the Elizabethtown area, Hardin County, in north-central Kentucky. The principal aquifer in the Elizabethtown area is thick, nearly horizontal beds of limestone, and thin beds of shale of Mississippi age. As much as 65% of all water pumped for the city water supply is obtained from two springs and two wells that obtain water from these rocks. Sinkholes were classified according to their ability to funnel runoff directly into the groundwater flow system, based primarily on the nature of the swallet draining the sinkhole. The presence of bedrock in the sinkhole nearly always ensured a well defined swallet leading to the subsurface. Qualitative and quantitative dye tracing techniques and equipment are discussed in detail. Qualitative dye tracing with fluorescein dye and passive dye detectors, consisting of activated coconut charcoal identified point to point connection between representative sinkholes, sinking streams, and karst windows and the city springs and wells. Qualitative tracing confirmed the presence of infiltrated surface water from a perennial stream, Valley Creek, in water from city wells and generally confirmed the direction of groundwater flow as shown by a water level contour map. Quantitative dye tracing with rhodamin WT, automatic samplers, discharge measurements, and fluorometric analyses were used to determine flow characteristics such as traveltime for arrival of the leading edge, peak concentration, trailing edge, and persistence of the dye cloud at the spring resurgence. Analyses of the dye recovery curves for quantitative dye traces completed between the same sinkholes and a city spring, and during different flow conditions showed that the arrival time of the leading edge of the dye cloud ranged from 5 to 24 hours and that the traveltime of the centroid of the dye cloud ranged from 6 to 31 hours when discharge was 4.6 and 0.53 cu ft/second, respectively. (Lantz-PTT)
Detection and quantification of reactive oxygen species (ROS) in indoor air.
Montesinos, V Nahuel; Sleiman, Mohamad; Cohn, Sebastian; Litter, Marta I; Destaillats, Hugo
2015-06-01
Reactive oxygen species (ROS), such as free radicals and peroxides, are environmental trace pollutants potentially associated with asthma and airways inflammation. These compounds are often not detected in indoor air due to sampling and analytical limitations. This study developed and validated an experimental method to sample, identify and quantify ROS in indoor air using fluorescent probes. Tests were carried out simultaneously using three different probes: 2',7'-dichlorofluorescin (DCFH) to detect a broad range of ROS, Amplex ultra Red® (AuR) to detect peroxides, and terephthalic acid (TPA) to detect hydroxyl radicals (HO(•)). For each test, air samples were collected using two impingers in series kept in an ice bath, containing each 10 mL of 50 mM phosphate buffer at pH 7.2. In tests with TPA, that probe was also added to the buffer prior to sampling; in the other two tests, probes and additional reactants were added immediately after sampling. The concentration of fluorescent byproducts was determined fluorometrically. Calibration curves were developed by reacting DCFH and AuR with known amounts of H2O2, and using known amounts of 2-hydroxyterephthalic acid (HTPA) for TPA. Low detection limits (9-13 nM) and quantification limits (18-22 nM) were determined for all three probes, which presented a linear response in the range 10-500 nM for AuR and TPA, and 100-2000 nM for DCFH. High collection efficiency (CE) and recovery efficiency (RE) were observed for DCFH (CE=RE=100%) and AuR (CE=100%; RE=73%) by sampling from a laboratory-developed gas phase H2O2 generator. Interference of co-occurring ozone was evaluated and quantified for the three probes by sampling from the outlet of an ozone generator. The method was demonstrated by sampling air emitted by two portable air cleaners: a strong ozone generator (AC1) and a plasma generator (AC2). High ozone levels emitted by AC1 did not allow for simultaneous determination of ROS levels due to high background levels associated with ozone decomposition in the buffer. However, emitted ROS were quantified at the outlet of AC2 using two of the three probes. With AuR, the concentration of peroxides in air emitted by the air cleaner was 300 ppt of H2O2 equivalents. With TPA, the HO(•) concentration was 47 ppt. This method is best suited to quantify ROS in the presence of low ozone levels. Published by Elsevier B.V.
Tracer simulation study of potential solute movement in Port Royal Sound, South Carolina
Kilpatrick, F.A.; Cummings, T. Ray
1972-01-01
A tracer study was conducted in Port Royal Sound to simulate the movement and ultimate pattern of concentration of a solute continuously injected into the flow. A total of 750 pounds of Rhodamine WT dye was injected by boat during a period of 24.8 hours in a line across the Colleton River. During the following 43 days, samples of water were taken at selected points in the sound, and the concentration of dye in the samples was determined by fluorometric analysis. The data obtained in the field study were used with theoretical models to compute the ultimate pattern of concentration of nonconservative and conservative solutes for a hypothetical continuous injection at the site on the Colleton River.
A flavonoid from Brassica rapa flower as the UV-absorbing nectar guide.
Sasaki, Katsunori; Takahashi, Takashi
2002-10-01
The corolla of Brassica rapa has an UV-absorbing zone in its center, known as the nectar guide for attracting pollinating insects. The pigment which plays the role of the nectar guide was isolated from the petals and identified to be isorhamnetin 3,7-O-di-beta-D-glucopyranoside on the basis of MS and NMR spectroscopic data. The D-, L-configurations of the sugar moieties were determined by the fluorometric HPLC method. In plants raised in open field, there was a 13-fold higher content of the compound in the basal parts of the petals compared with the apical parts. This difference in flavonoid content is presumed to contribute to the visual attractiveness of B. rapa flowers to insect pollinators.
M-DNA: a self-assembling molecular wire for nanoelectronics and biosensing.
Wettig, Shawn D; Li, Chen-Zhong; Long, Yi-Tao; Kraatz, Heinz-Bernhard; Lee, Jeremy S
2003-01-01
M-DNA is a complex between divalent metal ions such as Zn2+ and duplex DNA which forms at pH 8.5. Unlike B-DNA, M-DNA does not bind ethidium so that M-DNA formation can be monitored conveniently by an ethidium fluorescence assay. M-DNA was shown to be a better conductor than B-DNA by fluorometric measurements of electron transport in donor-acceptor labelled duplexes; by direct conductivity measurements of M-DNA bound between gold electrodes and by cyclic voltammetric studies on ferrocene labelled duplexes attached to gold microelectrodes. As is the case with B-DNA, M-DNA can self-assemble into a variety of structures and is anticipated to find widespread use in nanoelectronics and biosensing.
Čapek, Jan; Hauschke, Martina; Brůčková, Lenka; Roušar, Tomáš
2017-11-01
Fluorometric glutathione assays have been generally preferred for their high specificity and sensitivity. An additional advantage offered by fluorescent bimane dyes is their ability to penetrate inside the cell. Their ability to react with glutathione within intact cells is frequently useful in flow cytometry and microscopy. Hence, the aims of our study were to use monochlorobimane for optimizing a spectrofluorometric glutathione assay in cells and then to compare that assay with the frequently used ortho-phthalaldehyde assay. We used glutathione-depleting agents (e.g., cisplatin and diethylmalonate) to induce cell impairment. For glutathione assessment, monochlorobimane (40μM) was added to cells and fluorescence was detected at 394/490nm. In addition to the regularly used calculation of glutathione levels from fluorescence change after 60min, we used an optimized calculation from the linear part of the fluorescence curve after 10min of measurement. We found that 10min treatment of cells with monochlorobimane is sufficient for evaluating cellular glutathione concentration and provides results entirely comparable with those from the standard ortho-phthalaldehyde assay. In contrast, the results obtained by the standardly used evaluation after 60min of monochlorobimane treatment provided higher glutathione values. We conclude that measuring glutathione using monochlorobimane with the here-described optimized evaluation of fluorescence signal could be a simple and useful method for routine and rapid assessment of glutathione within intact cells in large numbers of samples. Copyright © 2017 Elsevier Inc. All rights reserved.
Korani, Walid Ahmed; Chu, Ye; Holbrook, Corley; Clevenger, Josh; Ozias-Akins, Peggy
2017-07-12
Aflatoxin contamination is a major economic and food safety concern for the peanut industry that largely could be mitigated by genetic resistance. To screen peanut for aflatoxin resistance, ten genotypes were infected with a green fluorescent protein (GFP)-expressing Aspergillus flavus strain. Percentages of fungal infected area and fungal GFP signal intensity were documented by visual ratings every 8 h for 72 h after inoculation. Significant genotypic differences in fungal growth rates were documented by repeated measures and area under the disease progress curve (AUDPC) analyses. SICIA (Seed Infection Coverage and Intensity Analyzer), an image processing software, was developed to digitize fungal GFP signals. Data from SICIA image analysis confirmed visual rating results validating its utility for quantifying fungal growth. Among the tested peanut genotypes, NC 3033 and GT-C20 supported the lowest and highest fungal growth on the surface of peanut seeds, respectively. Although differential fungal growth was observed on the surface of peanut seeds, total fungal growth in the seeds was not significantly different across genotypes based on a fluorometric GFP assay. Significant differences in aflatoxin B levels were detected across peanut genotypes. ICG 1471 had the lowest aflatoxin level whereas Florida-07 had the highest. Two-year aflatoxin tests under simulated late-season drought also showed that ICG 1471 had reduced aflatoxin production under pre-harvest field conditions. These results suggest that all peanut genotypes support A. flavus fungal growth yet differentially influence aflatoxin production.
Chu, Ye; Holbrook, Corley; Clevenger, Josh; Ozias-Akins, Peggy
2017-01-01
Aflatoxin contamination is a major economic and food safety concern for the peanut industry that largely could be mitigated by genetic resistance. To screen peanut for aflatoxin resistance, ten genotypes were infected with a green fluorescent protein (GFP)—expressing Aspergillus flavus strain. Percentages of fungal infected area and fungal GFP signal intensity were documented by visual ratings every 8 h for 72 h after inoculation. Significant genotypic differences in fungal growth rates were documented by repeated measures and area under the disease progress curve (AUDPC) analyses. SICIA (Seed Infection Coverage and Intensity Analyzer), an image processing software, was developed to digitize fungal GFP signals. Data from SICIA image analysis confirmed visual rating results validating its utility for quantifying fungal growth. Among the tested peanut genotypes, NC 3033 and GT-C20 supported the lowest and highest fungal growth on the surface of peanut seeds, respectively. Although differential fungal growth was observed on the surface of peanut seeds, total fungal growth in the seeds was not significantly different across genotypes based on a fluorometric GFP assay. Significant differences in aflatoxin B levels were detected across peanut genotypes. ICG 1471 had the lowest aflatoxin level whereas Florida-07 had the highest. Two-year aflatoxin tests under simulated late-season drought also showed that ICG 1471 had reduced aflatoxin production under pre-harvest field conditions. These results suggest that all peanut genotypes support A. flavus fungal growth yet differentially influence aflatoxin production. PMID:28704974
NASA Astrophysics Data System (ADS)
Zhao, Hongfang
Research described in this dissertation covers two topics. Part-I is focused on in-situ determination of neutral lipid content of microalgae using a lipophilic fluorescent dye. The traditional Nile red stain-based method for detecting microalgal intracellular lipids is limited due to varying composition and thickness of rigid cell walls. In this study, the addition of dilute acid and heating of solution, were found to greatly enhance staining efficiency of Nile red for microalgal species evaluated. Oil-in-water (O/W) microemulsion stabilized by a non-ionic surfactant was employed as a pseudo-standard that mimics lipid-bearing microalgal cells suspended in water. The average neutral lipid contents determined were very close to the results obtained by traditional gravimetric method and solid phase extraction. Part II of the dissertation explores thermo-physico-chemical properties of polymeric pattern materials, including expanded polystyrene (EPS) foam, polyurethane foam, and epoxy stereolithography (SLA) patterns, that are used in investment casting. Density, elastic modulus, expansion coefficient, thermal degradation behavior, etc. were experimentally investigated for their effects on metal casting quality. The reduction in toxic hydrogen cyanide (HCN) generated during thermal decomposition of polyurethane pattern was achieved by increasing either oxidant level or residence time in heated zone. Thermal degradation kinetics of the pattern materials were examined with a thermogravimetric analysis and activation energies were determined by Kissinger and Flynn-Wall-Ozawa methods.
In vitro binding and receptor-mediated activity of terlipressin at vasopressin receptors V1 and V2
Jamil, Khurram; Pappas, Stephen Chris; Devarakonda, Krishna R
2018-01-01
Terlipressin, a synthetic, systemic vasoconstrictor with selective activity at vasopressin-1 (V1) receptors, is a pro-drug for the endogenous/natural porcine hormone [Lys8]-vasopressin (LVP). We investigated binding and receptor-mediated cellular activities of terlipressin, LVP, and endogenous human hormone [Arg8]-vasopressin (AVP) at V1 and vasopressin-2 (V2) receptors. Cell membrane homogenates of Chinese hamster ovary cells expressing human V1 and V2 receptors were used in competitive binding assays to measure receptor-binding activity. These cells were used in functional assays to measure receptor-mediated cellular activity of terlipressin, LVP, and AVP. Binding was measured by [3H]AVP counts, and the activity was measured by fluorometric detection of intracellular calcium mobilization (V1) and cyclic adenosine monophosphate (V2). Binding potency at V1 and V2 was AVP>LVP>>terlipressin. LVP and terlipressin had approximately sixfold higher affinity for V1 than for V2. Cellular activity potency was also AVP>LVP>>terlipressin. Terlipressin was a partial agonist at V1 and a full agonist at V2; LVP was a full agonist at both V1 and V2. The in vivo response to terlipressin is likely due to the partial V1 agonist activity of terlipressin and full V1 agonist activity of its metabolite, LVP. These results provide supportive evidence for previous findings and further establish terlipressin pharmacology for vasopressin receptors. PMID:29302194
In vitro binding and receptor-mediated activity of terlipressin at vasopressin receptors V1 and V2.
Jamil, Khurram; Pappas, Stephen Chris; Devarakonda, Krishna R
2018-01-01
Terlipressin, a synthetic, systemic vasoconstrictor with selective activity at vasopressin-1 (V 1 ) receptors, is a pro-drug for the endogenous/natural porcine hormone [Lys 8 ]-vasopressin (LVP). We investigated binding and receptor-mediated cellular activities of terlipressin, LVP, and endogenous human hormone [Arg 8 ]-vasopressin (AVP) at V 1 and vasopressin-2 (V 2 ) receptors. Cell membrane homogenates of Chinese hamster ovary cells expressing human V 1 and V 2 receptors were used in competitive binding assays to measure receptor-binding activity. These cells were used in functional assays to measure receptor-mediated cellular activity of terlipressin, LVP, and AVP. Binding was measured by [ 3 H]AVP counts, and the activity was measured by fluorometric detection of intracellular calcium mobilization (V 1 ) and cyclic adenosine monophosphate (V 2 ). Binding potency at V 1 and V 2 was AVP>LVP>terlipressin. LVP and terlipressin had approximately sixfold higher affinity for V 1 than for V 2 . Cellular activity potency was also AVP>LVP>terlipressin. Terlipressin was a partial agonist at V 1 and a full agonist at V 2 ; LVP was a full agonist at both V 1 and V 2 . The in vivo response to terlipressin is likely due to the partial V 1 agonist activity of terlipressin and full V 1 agonist activity of its metabolite, LVP. These results provide supportive evidence for previous findings and further establish terlipressin pharmacology for vasopressin receptors.
Kynurenic acid content in anti-rheumatic herbs.
Zgrajka, Wojciech; Turska, Monika; Rajtar, Grażyna; Majdan, Maria; Parada-Turska, Jolanta
2013-01-01
The use of herbal medicines is common among people living in rural areas and increasingly popular in urbanized countries. Kynurenic acid (KYNA) is a metabolite of kynurenine possessing anti-inflammatory, anti-oxidative and pain reliving properties. Previous data indicated that the content of KYNA in the synovial fluid of patients with rheumatoid arthritis is lower than in patients with osteoarthritis. Rheumatoid arthritis is a chronic, systemic inflammatory disorder affecting about 1% of the world's population. The aim of the presented study was to investigate the content of KYNA in 11 herbal preparations used in rheumatic diseases. The following herbs were studied: bean pericarp, birch leaf, dandelion root, elder flower, horsetail herb, nettle leaf, peppermint leaf and willow bark. An anti-rheumatic mixture of the herbs Reumatefix and Reumaflos tea were also investigated. The herbs were prepared according to producers' directions. In addition, the herbal supplement Devil's Claw containing root of Harpagophytum was used. KYNA content was measured using the high-performance liquid chromatography method, and KYNA was detected fluorometrically. KYNA was found in all studied herbal preparations. The highest content of KYNA was found in peppermint, nettle, birch leaf and the horsetail herb. The lowest content of KYNA was found in willow bark, dandelion root and in the extract from the root of Harpagophytum. These findings indicate that the use of herbal preparations containing a high level of KYNA can be considered as a supplementary measure in rheumatoid arthritis therapy, as well as in rheumatic diseases prevention.
Novel Application of FTIR Spectroscopy for the Passive Standoff Detection of Radiological Materials
2006-08-01
possibility of applying the long-wave passive standoff detection technique to the identification of radiological materials. This work is based on...infrared (FTIR) radiometry is a well-known technique for detecting and identifying chemical warfare agents. In addition to these potential threats...necessary tools and techniques available for detecting and identifying radioactive products. At present, the main detection techniques depend on methods
Sun, Zong-ke; Wu, Rong; Ding, Pei; Xue, Jin-Rong
2006-07-01
To compare between rapid detection method of enzyme substrate technique and multiple-tube fermentation technique in water coliform bacteria detection. Using inoculated and real water samples to compare the equivalence and false positive rate between two methods. Results demonstrate that enzyme substrate technique shows equivalence with multiple-tube fermentation technique (P = 0.059), false positive rate between the two methods has no statistical difference. It is suggested that enzyme substrate technique can be used as a standard method for water microbiological safety evaluation.
Kim-Kang, H; Crouch, L S; Bova, A; Robinson, R A; Wu, J
2001-11-01
An accurate, reliable, and reproducible assay for the determination of residual concentrations of emamectin B(1a) in muscle, skin, and intact muscle/skin in natural proportions from Atlantic salmon treated with SCH 58854 (emamectin benzoate) is described. The determinative method was developed and validated using fortified control tissues at five levels over a range of 50-800 ng/g as well as tissues containing incurred levels in the same range. Incurred tissues were obtained from a metabolism study of [(3)H]emamectin benzoate in Atlantic salmon. The assay employs processing of a tissue ethyl acetate extract on a propylsulfonic acid solid phase extraction cartridge, followed by derivatization with trifluoroacetic anhydride in the presence of N-methylimidazole. Following separation using reversed phase HPLC, the amount of derivatized emamectin B(1a) is determined by fluorescence detection. The theoretical limits of detection were determined from the analysis of control tissue matrices to be 2.6, 3.3, and 3.8 ng/g as emamectin B(1a) for muscle, skin, and intact muscle/skin, respectively. Likewise, the theoretical limits of quantitation (LOQ) were determined to be 6.9, 8.1, and 9.5 ng/g as emamectin B(1a) for muscle, skin, and intact muscle/skin, respectively. The lowest fortification level used for method validation was 50 ng/g, which served as the effective LOQ for the method. The overall percent recoveries (+/-% CV) were 94.4 +/- 6.89% (n = 25) for muscle, 88.4 +/- 5.35% (n = 25) for skin, and 88.0 +/- 3.73% for intact muscle/skin (n = 25). Accuracy, precision, linearity, selectivity, and ruggedness were demonstrated. The structure of the final fluorescent derivative of emamectin B(1a) free base was identified by ESI(+)/LC-MS. The frozen storage stability of [(3)H]emamectin B(1a) in tissues with incurred residues was demonstrated for approximately 15 months by radiometric analysis and for an additional approximately 13 months by fluorometric analysis for a total of approximately 28 months.
Ishimatsu, Ryoichi; Naruse, Azusa; Liu, Rong; Nakano, Koji; Yahiro, Masayuki; Adachi, Chihaya; Imato, Toshihiko
2013-12-15
An organic thin film photodiode (OPD) was successfully employed as a portable photodetector in a competitive enzyme-linked immunosorbent assay (ELISA) of a class of nonionic surfactants, namely alkylphenol polyethoxylates (APnEOs) which are an environmental pollutant. Microbeads that were chemically immobilized with an anti-APnEOs antibody were used in the assay. The OPD consisted of a layer of copper phthalocyanine (CuPc), C60 and a second layer of bathocuproine (BCP) with a bulk heterojunction composed of CuPc and C60 prepared by a vapor deposition method on an indium-tin oxide coated glass substrate. The OPD showed an incident photon-current efficiency (IPCE) of approximately 19% for light at a wavelength of 585 nm. This relatively high IPCE at 585 nm makes it suitable for detecting the fluorescence of resorufin (λem=585 nm), the product of the competitive ELISA, produced through the enzymatic reaction of Amplex Red with horseradish peroxidase (HRP) and H2O2. A fluorometric detector was assembled on a microchip by combining the fabricated OPD and a commercial LED as a photodetector and a light source, respectively. The photocurrent of the OPD due to the fluorescence of resorufin was proportional to the concentration of resorufin in the concentration range from 0 to 8 μM. When the fabricated OPD was used as a portable photodetector, the competitive ELISA of APnEOs using HRP labeled APnEOs (HRP-APnEOs) was performed on magnetic microbeads on which surface an anti-APnEOs antibody had been immobilized. A typical sigmoidal calibration curve was obtained and the data were in good agreement with a numerical simulation, where the photocurrent of the OPD was plotted against the concentration of APnEOs, determined via the competitive ELISA. The detection limit of the immunoassay for APnEOs was approximately 2 and 4 ppb in batch and flow system, respectively. © 2013 Elsevier B.V. All rights reserved.
Phosphatase activity in Antarctica soil samples as a biosignature of extant life
NASA Astrophysics Data System (ADS)
Sato, Shuji; Itoh, Yuki; Takano, Yoshinori; Fukui, Manabu; Kaneko, Takeo; Kobayashi, Kensei
Microbial activities have been detected in such extreme terrestrial environments as deep lithosphere, a submarine hydrothermal systems, stratosphere, and Antarctica. Microorganisms have adapted to such harsh environments by evolving their biomolecules. Some of these biomolecules such as enzymes might have different characteristics from those of organisms in ordinary environments. Many biosignatures (or biomarkers) have been proposed to detect microbial activities in such extreme environments. A number of techniques are proposed to evaluate biological activities in extreme environments including cultivation methods, assay of metabolism, and analysis of bioorganic compounds like amino acids and DNA. Enzyme activities are useful signature of extant life in extreme environments. Among many enzymes, phosphatase could be a good indicator of biological activities, since phosphate esters are essential for all the living terrestrial organisms. In addition, alkaline phosphatase is known as a typical zinc-containing metalloenzyme and quite stable in environments. We analyzed phosphatase activities in Antarctica soil samples to see whether they can be used as biosignatures for extant life. In addition, we characterized phosphatases extracted from the Antarctica soil samples, and compared with those obtained from other types of environments. Antarctica surface environments are quite severe environments for life since it is extremely cold and dry and exposed to strong UV and cosmic rays. We tried to evaluate biological activities in Antarctica by measuring phosphatase activities. Surface soil samples are obtained at the Sites 1-8 near Showa Base in Antarctica during the 47th Japan Antarctic exploration mission in 2005-6. Activities of acid phosphatase (ACP) and alkaline phosphatase (ALP) are measured spectrophotometrically after mixing the powdered sample and p-nitrophenyl phosphate solution (pH 6.5 for ACP, pH 8.0 for ALP). ALP was characterized after extraction from soils with Tris-HCl buffer (pH 9.0), where the activity was measured fluorometrically with 4-methylumbelliferyl phosphate (pH 8.0) as a substance. The soil of Site 8 (near a penguin rookery) showed almost the same level of ACP and ALP activities as usual surface soil sampled in YNU campus, while the soil of Sites 1-7 showed much less activities. ALP in the extract from the soil of Site 8 was characterized. It showed the maximal at 338 K, while ALP from the campus soil showed the maximal at 358 K. Gel filtration chromatography showed that the ALP activity was found only in the fraction whose molecular weights were over 60000. The ALP activity was diminished with EDTA and was recovered with addition of zinc ion. The present results showed that zinc-containing metalloenzymes, which had lower optimum temperature than those in usual environments, are present in Antarctica soil. It was suggested that phosphatases are good bio-signatures for extant life in extreme environments.
Overview of hybridization and detection techniques.
Hilario, Elena
2007-01-01
A misconception regarding the sensitivity of nonradioactive methods for screening genomic DNA libraries often hinders the establishment of these environmentally friendly techniques in molecular biology laboratories. Nonradioactive probes, properly prepared and quantified, can detect DNA target molecules to the femtomole range. However, appropriate hybridization techniques and detection methods should also be adopted for an efficient use of nonradioactive techniques. Detailed descriptions of genomic library handling before and during the nonradioactive hybridization and detection are often omitted from publications. This chapter aims to fill this void by providing a collection of technical tips on hybridization and detection techniques.
Evaluation of change detection techniques for monitoring coastal zone environments
NASA Technical Reports Server (NTRS)
Weismiller, R. A. (Principal Investigator); Kristof, S. J.; Scholz, D. K.; Anuta, P. E.; Momin, S. M.
1977-01-01
The author has identified the following significant results. Four change detection techniques were designed and implemented for evaluation: (1) post classification comparison change detection, (2) delta data change detection, (3) spectral/temporal change classification, and (4) layered spectral/temporal change classification. The post classification comparison technique reliably identified areas of change and was used as the standard for qualitatively evaluating the other three techniques. The layered spectral/temporal change classification and the delta data change detection results generally agreed with the post classification comparison technique results; however, many small areas of change were not identified. Major discrepancies existed between the post classification comparison and spectral/temporal change detection results.
Murphy, Patrick J. M.
2014-01-01
Background Hydrophobic interaction chromatography (HIC) most commonly requires experimental determination (i.e., scouting) in order to select an optimal chromatographic medium for purifying a given target protein. Neither a two-step purification of untagged green fluorescent protein (GFP) from crude bacterial lysate using sequential HIC and size exclusion chromatography (SEC), nor HIC column scouting elution profiles of GFP, have been previously reported. Methods and Results Bacterial lysate expressing recombinant GFP was sequentially adsorbed to commercially available HIC columns containing butyl, octyl, and phenyl-based HIC ligands coupled to matrices of varying bead size. The lysate was fractionated using a linear ammonium phosphate salt gradient at constant pH. Collected HIC eluate fractions containing retained GFP were then pooled and further purified using high-resolution preparative SEC. Significant differences in presumptive GFP elution profiles were observed using in-line absorption spectrophotometry (A395) and post-run fluorimetry. SDS-PAGE and western blot demonstrated that fluorometric detection was the more accurate indicator of GFP elution in both HIC and SEC purification steps. Comparison of composite HIC column scouting data indicated that a phenyl ligand coupled to a 34 µm matrix produced the highest degree of target protein capture and separation. Conclusions Conducting two-step protein purification using the preferred HIC medium followed by SEC resulted in a final, concentrated product with >98% protein purity. In-line absorbance spectrophotometry was not as precise of an indicator of GFP elution as post-run fluorimetry. These findings demonstrate the importance of utilizing a combination of detection methods when evaluating purification strategies. GFP is a well-characterized model protein, used heavily in educational settings and by researchers with limited protein purification experience, and the data and strategies presented here may aid in development other of HIC-compatible protein purification schemes. PMID:25254496
Zheng, Jinfen; Lai, Wei; Zhu, Guoxing; Wan, Miaojian; Chen, Jian; Tai, Yan; Lu, Chun
2013-10-01
10-Hydroxy-2-decenoic acid (10-HDA) is a major fatty acid component of royal jelly, which has been reported to have a variety of beneficial pharmacological characteristics. However, the effects of 10-HDA on skin photoageing and its potential mechanism of action are unclear. We investigated the protective effects of 10-HDA on ultraviolet (UV) A-induced damage in human dermal fibroblasts (HDFs). We then explored the inhibitory effects of 10-HDA on UVA-induced matrix metalloproteinases (MMPs) expression and elucidated the signalling pathways controlling MMPs inhibition. Primary human dermal fibroblasts were exposed to UVA. Cell proliferation, cellular senescent state and collagen content were analysed using CCK-8, senescence-associated β-galactosidase staining and Sircol collagen assay, respectively. Fluorometric assays were performed to detect the formation of reactive oxygen species (ROS) in the cells. The mRNA levels of MMP-1, MMP-3 and type I (α1) collagen were determined by quantitative real-time PCR. Western blot was applied to detect the expression of MMP-1, MMP-3, JNK and p38 MAPK. HDFs treated with 10-HDA were significantly protected from UVA-induced cytotoxicity, ROS, cellular senescence and stimulated collagen production. Moreover, 10-HDA suppressed the UVA-induced expression of MMP-1 and MMP-3 at both the transcriptional and protein levels. Treatment with 10-HDA also reduced the UVA-induced activation of the JNK and p38 MAPK pathways. The data obtained in this study provide evidence that 10-HDA could prevent UVA-induced damage and inhibit MMP-1 and MMP-3 expressions. Therefore, 10-HDA may be a potential agent for the prevention and treatment of skin photoageing. © 2012 The Authors. Journal of the European Academy of Dermatology and Venereology © 2012 European Academy of Dermatology and Venereology.
Drop-off Detection with the Long Cane: Effects of Different Cane Techniques on Performance
Kim, Dae Shik; Emerson, Robert Wall; Curtis, Amy
2010-01-01
This study compared the drop-off detection performance with the two-point touch and constant contact cane techniques using a repeated-measures design with a convenience sample of 15 cane users with visual impairments. The constant contact technique was superior to the two-point touch technique in the drop-off detection rate and the 50% detection threshold. The findings may help an orientation and mobility instructor select an appropriate technique for a particular client or training situation. PMID:21209791
Feasibility Study of Radiometry for Airborne Detection of Aviation Hazards
NASA Technical Reports Server (NTRS)
Gimmestad, Gary G.; Papanicolopoulos, Chris D.; Richards, Mark A.; Sherman, Donald L.; West, Leanne L.; Johnson, James W. (Technical Monitor)
2001-01-01
Radiometric sensors for aviation hazards have the potential for widespread and inexpensive deployment on aircraft. This report contains discussions of three aviation hazards - icing, turbulence, and volcanic ash - as well as candidate radiometric detection techniques for each hazard. Dual-polarization microwave radiometry is the only viable radiometric technique for detection of icing conditions, but more research will be required to assess its usefulness to the aviation community. Passive infrared techniques are being developed for detection of turbulence and volcanic ash by researchers in this country and also in Australia. Further investigation of the infrared airborne radiometric hazard detection approaches will also be required in order to develop reliable detection/discrimination techniques. This report includes a description of a commercial hyperspectral imager for investigating the infrared detection techniques for turbulence and volcanic ash.
A Survey on Anomaly Based Host Intrusion Detection System
NASA Astrophysics Data System (ADS)
Jose, Shijoe; Malathi, D.; Reddy, Bharath; Jayaseeli, Dorathi
2018-04-01
An intrusion detection system (IDS) is hardware, software or a combination of two, for monitoring network or system activities to detect malicious signs. In computer security, designing a robust intrusion detection system is one of the most fundamental and important problems. The primary function of system is detecting intrusion and gives alerts when user tries to intrusion on timely manner. In these techniques when IDS find out intrusion it will send alert massage to the system administrator. Anomaly detection is an important problem that has been researched within diverse research areas and application domains. This survey tries to provide a structured and comprehensive overview of the research on anomaly detection. From the existing anomaly detection techniques, each technique has relative strengths and weaknesses. The current state of the experiment practice in the field of anomaly-based intrusion detection is reviewed and survey recent studies in this. This survey provides a study of existing anomaly detection techniques, and how the techniques used in one area can be applied in another application domain.
Measurement techniques investigated for detection of hydrogen chloride gas in ambient air
NASA Technical Reports Server (NTRS)
Gregory, G. L.
1976-01-01
Nine basic techniques are discussed, ranging from concentration (parts per million) to dosage only (parts per million-seconds) measurement techniques. Data for each technique include lower detection limit, response time, instrument status, and in some cases, specificity. Several techniques discussed can detect ambient hydrogen chloride concentrations below 1 part per million with a response time of seconds.
Effects of selenium supplementation in cattle on aquatic ecosystems in northern California
DOE Office of Scientific and Technical Information (OSTI.GOV)
Norman, B.; Nader, G.; Oliver, M.
1992-09-15
The potential impact on aquatic ecosystems of supplementing the diets of beef cattle with selenium (Se) was studied on 4 northern California ranches. All study sites included an area of concentrated use by cattle that had diets supplemented with Se. In each case, a stream flowed through the site and provided a control sampling area upstream and a treated sampling area downstream. Specimens of water, sediment, algae, aquatic plants, aquatic invertebrates, and fish were analyzed fluorometrically for total Se content. Significant differences in Se concentration were not found between specimens from upstream control areas and those from downstream areas subjectedmore » to use by Se-treated cattle. Evidence was not found that Se supplementation in cattle at maximal permitted concentrations caused Se accumulation in associated aquatic ecosystems.« less
Change detection from remotely sensed images: From pixel-based to object-based approaches
NASA Astrophysics Data System (ADS)
Hussain, Masroor; Chen, Dongmei; Cheng, Angela; Wei, Hui; Stanley, David
2013-06-01
The appetite for up-to-date information about earth's surface is ever increasing, as such information provides a base for a large number of applications, including local, regional and global resources monitoring, land-cover and land-use change monitoring, and environmental studies. The data from remote sensing satellites provide opportunities to acquire information about land at varying resolutions and has been widely used for change detection studies. A large number of change detection methodologies and techniques, utilizing remotely sensed data, have been developed, and newer techniques are still emerging. This paper begins with a discussion of the traditionally pixel-based and (mostly) statistics-oriented change detection techniques which focus mainly on the spectral values and mostly ignore the spatial context. This is succeeded by a review of object-based change detection techniques. Finally there is a brief discussion of spatial data mining techniques in image processing and change detection from remote sensing data. The merits and issues of different techniques are compared. The importance of the exponential increase in the image data volume and multiple sensors and associated challenges on the development of change detection techniques are highlighted. With the wide use of very-high-resolution (VHR) remotely sensed images, object-based methods and data mining techniques may have more potential in change detection.
NASA Astrophysics Data System (ADS)
Tolmasov, M.; Barbiro-Michaely, E.; Mayevsky, A.
2009-02-01
Nitric oxide is a mediator in many physiological processes including vasodilatation of blood vessels, neurotransmission and prevention of platelet aggregation. It has also a role in the pathophysiology of sepsis, hemorrhagic shock, various traumatic events and critical conditions involved with circulatory abnormalities. The last one is accompanied by blood flow redistribution and is considered to be the putative cause of altered oxygen metabolism in various pathophysiological conditions. The present study tested the involvement of NO in the brain as a vital organ versus the small intestine, a less vital organ using the non-specific nitric oxide synthase inhibitor L-NAME and exogenous NO donor - nitrite. The parameters that were simultaneously monitored in both organs included mean arterial blood pressure (MAP), tissue blood flow (TBF), using laser Doppler flowmetery and NADH fluorescence using the fluorometric technique. Three groups were tested. Group 1 - L-NAME +nitrite, group 2 - control L-NAME and group 3 - control nitrite. Following LNAME, MAP significantly increased and remained elevated through the entire experiment. TBF decreased in both organs with full recovery in the brain and no recovery in the intestine, whereas NADH showed no significant changes. Nitrite alone had no significant effect on the parameters in any of the organs. In group 1 the infusion of nitrite decreased the level of elevated MAP earlier induced by L-NAME. Nitrite also recovered the reduced TBF in the brain whereas it had no beneficial effect on intestinal blood flow indicating for its regulatory role in the brain but not in the intestine.
Local mediator release after antigen challenge of a bronchial segment in allergic dogs.
Reiss, T F; Rubinstein, I; Emery, D L; Gold, W M; Boushey, H A
1989-12-01
To investigate the local intraluminal bronchial response to an antigenic stimulus, we developed a bronchoscopic double-balloon system to challenge and lavage a segment of the left main-stem bronchus. We studied whether fluid from above or below the occlusion balloons leaked into the bronchial segment. Lavage was performed before and after placement of red and blue pigments proximal and distal to the inflated balloons, respectively, and the recovered lavage fluid was analyzed visually and spectrophotometrically in three experiments. There was no evidence for pigment leakage into the segment. In six anesthetized ragweed-allergic dogs, local ragweed antigen challenges were performed. After balloon inflation in the left main-stem bronchus, we performed two baseline lavages of the interballoon segment, introduced a ragweed antigen solution, and performed two postchallenge lavages. The recovered fluid was analyzed for the concentrations of prostaglandin D2 (PGD2; radioimmunoassay) and histamine (fluorometric technique) and for total and differential cell counts. Antigen challenge was associated with a significant increase in PGD2 concentration in the recovered fluid, rising from a median of 178 pg/ml (range, 157-647) before to 919 pg/ml (range, 149-2,452) after challenge. Median histamine concentrations were 3.1 ng/ml (range, 1-5.4 ng/ml) before and 5.6 ng/ml (range, 1-16.2) after challenge (P = not significant). In four dogs, a control challenge with the antigen vehicle alone showed no change in either mediator. Changes in cell counts after challenge were inconsistent.(ABSTRACT TRUNCATED AT 250 WORDS)
Cerebral energy metabolism in diving and non-diving birds during hypoxia and apnoeic asphyxia.
Bryan, R M; Jones, D R
1980-01-01
1. Cerebral energy metabolism during apnoeic asphyxia and steady-state hypoxia was compared in ducks and chickens; ducks tolerate apnoeic asphyxia 3-8 times longer than chickens. 2. Fluctuations in the reduced form of respiratory chain nicotinamide adenine dinucleotide (NADH) were monitored from the left cerebral hemisphere by a noninvasive fluorometric technique and used as an indicator of mitochondrial hypoxia. NADH fluorescence was expressed in aribtrary units (a.u.) where 100 a.u. was defined as the fluorescence change from normoxia to anoxia. Electroencephalogram (e.e.g.) and surface Po2 were recorded from the right hemisphere. 3. After 1 min of asphyxia NADH fluorescence increased by 37 a.u.+/-3.60 S.E. of mean (n=54) in paralysed chickens and 8 a.u.+/-1.41 (n=55) in aralysed ducks. After 2 min the fluorescence increased by only 15 a.u.+/-1.95 in ducks. 4. Both species showed an isoelectric e.e.g. when fluorescence increased by approximately 35 a.u., indicating that anaerobic ATP production in ducks did not maintain brain function (e.e.g.) for a greater accumulation of respiratory chain NADH. 5. At a given decrease in tissue Po2 ducks and chickens showed the same level of NADH increase, indicating that both species are equally dependent on tissue Po2 for the maintenance of redox state. 6. We conclude that biochemical adjustment which enhance anaerobic ATP production and/or prolong oxidative phosphorylation during progressive hypoxia are not responsible for increased cerebral tolerance to apnoeic asphyxia in the duck. PMID:7381772
NONDESTRUCTIVE TESTING (NDT) TECHNIQUES TO DETECT CONTAINED SUBSURFACE HAZARDOUS WASTE
The project involves the detection of buried containers with NDT (remote-sensing) techniques. Seventeen techniques were considered and four were ultimately decided upon. They were: electromagnetic induction (EMI); metal detection (MD); magnetometer (MAG); and ground penetrating r...
2015-01-01
for IC fault detection . This section provides background information on inversion methods. Conventional inversion techniques and their shortcomings are...physical techniques, electron beam imaging/analysis, ion beam techniques, scanning probe techniques. Electrical tests are used to detect faults in 13 an...hand, there is also the second harmonic technique through which duty cycle degradation faults are detected by collecting the magnitude and the phase of
Huang, Yichun; Ding, Weiwei; Zhang, Zhuomin; Li, Gongke
2013-07-01
This paper summarizes the recent developments of the rapid detection methods for food security, such as sensors, optical techniques, portable spectral analysis, enzyme-linked immunosorbent assay, portable gas chromatograph, etc. Additionally, the applications of these rapid detection methods coupled with sample pretreatment techniques in real food security analysis are reviewed. The coupling technique has the potential to provide references to establish the selective, precise and quantitative rapid detection methods in food security analysis.
Spatial and Temporal Monitoring Resolutions for CO2 Leakage Detection at Carbon Storage Sites
NASA Astrophysics Data System (ADS)
Yang, Y. M.; Dilmore, R. M.; Daley, T. M.; Carroll, S.; Mansoor, K.; Gasperikova, E.; Harbert, W.; Wang, Z.; Bromhal, G. S.; Small, M.
2016-12-01
Different leakage monitoring techniques offer different strengths in detection sensitivity, coverage, feedback time, cost, and technology availability, such that they may complement each other when applied together. This research focuses on quantifying the spatial coverage and temporal resolution of detection response for several geophysical remote monitoring and direct groundwater monitoring techniques for an optimal monitoring plan for CO2 leakage detection. Various monitoring techniques with different monitoring depths are selected: 3D time-lapse seismic survey, wellbore pressure, groundwater chemistry and soil gas. The spatial resolution in terms of leakage detectability is quantified through the effective detection distance between two adjacent monitors, given the magnitude of leakage and specified detection probability. The effective detection distances are obtained either from leakage simulations with various monitoring densities or from information garnered from field test data. These spatial leakage detection resolutions are affected by physically feasible monitoring design and detection limits. Similarly, the temporal resolution, in terms of leakage detectability, is quantified through the effective time to positive detection of a given size of leak and a specified detection probability, again obtained either from representative leakage simulations with various monitoring densities or from field test data. The effective time to positive detection is also affected by operational feedback time (associated with sampling, sample analysis and data interpretation), with values obtained mainly through expert interviews and literature review. In additional to the spatial and temporal resolutions of these monitoring techniques, the impact of CO2 plume migration speed and leakage detection sensitivity of each monitoring technique are also discussed with consideration of how much monitoring is necessary for effective leakage detection and how these monitoring techniques can be better combined in a time-space framework. The results of the spatial and temporal leakage detection resolutions for several geophysical monitoring techniques and groundwater monitoring are summarized to inform future monitoring designs at carbon storage sites.
Watabe, Tadashi; Naka, Sadahiro; Ikeda, Hayato; Horitsugi, Genki; Kanai, Yasukazu; Isohashi, Kayako; Ishibashi, Mana; Kato, Hiroki; Shimosegawa, Eku; Watabe, Hiroshi; Hatazawa, Jun
2014-01-01
Acetylcholinesterase (AChE) inhibitors have been used for patients with Alzheimer's disease. However, its pharmacokinetics in non-target organs other than the brain has not been clarified yet. The purpose of this study was to evaluate the relationship between the whole-body distribution of intravenously administered (11)C-Donepezil (DNP) and the AChE activity in the normal rat, with special focus on the adrenal glands. The distribution of (11)C-DNP was investigated by PET/CT in 6 normal male Wistar rats (8 weeks old, body weight = 220 ± 8.9 g). A 30-min dynamic scan was started simultaneously with an intravenous bolus injection of (11)C-DNP (45.0 ± 10.7 MBq). The whole-body distribution of the (11)C-DNP PET was evaluated based on the Vt (total distribution volume) by Logan-plot analysis. A fluorometric assay was performed to quantify the AChE activity in homogenized tissue solutions of the major organs. The PET analysis using Vt showed that the adrenal glands had the 2nd highest level of (11)C-DNP in the body (following the liver) (13.33 ± 1.08 and 19.43 ± 1.29 ml/cm(3), respectively), indicating that the distribution of (11)C-DNP was the highest in the adrenal glands, except for that in the excretory organs. The AChE activity was the third highest in the adrenal glands (following the small intestine and the stomach) (24.9 ± 1.6, 83.1 ± 3.0, and 38.5 ± 8.1 mU/mg, respectively), indicating high activity of AChE in the adrenal glands. We demonstrated the whole-body distribution of (11)C-DNP by PET and the AChE activity in the major organs by fluorometric assay in the normal rat. High accumulation of (11)C-DNP was observed in the adrenal glands, which suggested the risk of enhanced cholinergic synaptic transmission by the use of AChE inhibitors.
Sarma, Dominik; Gawlitza, Kornelia; Rurack, Knut
2016-04-19
The need for rapid and high-throughput screening in analytical laboratories has led to significant growth in interest in suspension array technologies (SATs), especially with regard to cytometric assays targeting a low to medium number of analytes. Such SAT or bead-based assays rely on spherical objects that constitute the analytical platform. Usually, functionalized polymer or silica (SiO2) microbeads are used which each have distinct advantages and drawbacks. In this paper, we present a straightforward synthetic route to highly monodisperse SiO2-coated polystyrene core-shell (CS) beads for SAT with controllable architectures from smooth to raspberry- and multilayer-like shells by varying the molecular weight of poly(vinylpyrrolidone) (PVP), which was used as the stabilizer of the cores. The combination of both organic polymer core and a structurally controlled inorganic SiO2 shell in one hybrid particle holds great promises for flexible next-generation design of the spherical platform. The particles were characterized by electron microscopy (SEM, T-SEM, and TEM), thermogravimetry, flow cytometry, and nitrogen adsorption/desorption, offering comprehensive information on the composition, size, structure, and surface area. All particles show ideal cytometric detection patterns and facile handling due to the hybrid structure. The beads are endowed with straightforward modification possibilities through the defined SiO2 shells. We successfully implemented the particles in fluorometric SAT model assays, illustrating the benefits of tailored surface area which is readily available for small-molecule anchoring. Very promising assay performance was shown for DNA hybridization assays with quantification limits down to 8 fmol.
Periapical fluid RANKL and IL-8 are differentially regulated in pulpitis and apical periodontitis.
Rechenberg, Dan-K; Bostanci, Nagihan; Zehnder, Matthias; Belibasakis, Georgios N
2014-09-01
The dental pulp space can become infected due to a breach in the surrounding hard tissues. This leads to inflammation of the pulp (pulpitis), soft tissue breakdown, and finally to bone loss around the root apex (apical periodontitis). The succession of the molecular events leading to apical periodontitis is currently not known. The main inflammatory mediator associated with neutrophil chemotaxis is interleukin-8 (IL-8), and with bone resorption the dyad of receptor activator of NF-κB ligand (RANKL) and osteoprotegerin (OPG). The levels of RANKL, OPG and IL-8 were studied in periapical tissue fluid of human teeth (n = 48) diagnosed with symptomatic irreversible pulpitis (SIP) and asymptomatic apical periodontitis (AAP). SIP represents the starting point, and AAP an established steady state of the disease. Periapical tissue fluid samples were collected using paper points and then evaluated using enzyme-linked immunosorbent assays (ELISAs). Target protein levels per case were calibrated against the corresponding total protein content, as determined fluorometrically. RANKL was expressed at significantly higher levels in SIP compared to AAP (P < 0.05), whereas OPG was under the detection limit in most samples. In contrast, IL-8 levels were significantly lower in SIP compared to AAP (P < 0.05). Spearman's correlation analysis between RANKL and IL-8 revealed a significantly (P < 0.05) negative correlation between the two measures (rho = -.44). The results of this study suggest that, in the development of apical periodontitis, periapical bone resorption signaling, as determined by RANKL, occurs prior to inflammatory cell recruitment signaling, as determined by IL-8. Copyright © 2014 Elsevier Ltd. All rights reserved.
Kumi, J; Mitchell, N J; Asare, G A; Dotse, E; Kwaa, F; Phillips, T D; Ankrah, N-A
2014-09-01
Weanimix is an important food for children in Ghana. Mothers are trained to prepare homemade weanimix from beans, groundnuts and maize for their infants. Groundnuts and maize are prone to aflatoxin contamination while fumonisin contaminates maize. Aflatoxin, is produced by the Asperguillus fungi while fumonisin, is produced by Fusarium fungi. These mycotoxins occur in tropical areas worldwide due to favorable climate for their growth. The objective of the study was to determine the levels of aflatoxin and fumonisin in homemade weanimix in the Ejura-Sekyedumase district in the Ashanti Region of Ghana. Thirty six homemade weanimix samples (50g each) were collected from households. Aflatoxin and fumonisin were measured using a fluorometric procedure described by the Association of Official Analytical Chemist (AOAC official method 993.31, V1 series 4). Aflatoxin and fumonisin were detected in all 36 samples, range 7.9-500ppb. Fumonisin levels range: 0.74-11.0ppm). Thirty (83.3%) of the thirty six samples were over the action limit of 20ppb for aflatoxin with an overall mean of 145.2 ppb whiles 58.3% of the samples had fumonisins above the action limit of 4 ppm with an overall mean of 4.7 ppm. There were significant aflatoxin and fumonisin contamination of homemade weanimix. Children fed on this nutritional food were being exposed to unacceptable levels of aflatoxin and fumonisin. Therefore there is a critical need to educate mothers on the dangers of mycotoxin exposure and to develop strategies to eliminate exposure of children fed homemade weanimix to aflatoxin and fumonisin.
Validated spectrofluorometric methods for determination of amlodipine besylate in tablets
NASA Astrophysics Data System (ADS)
Abdel-Wadood, Hanaa M.; Mohamed, Niveen A.; Mahmoud, Ashraf M.
2008-08-01
Two simple and sensitive spectrofluorometric methods have been developed and validated for determination of amlodipine besylate (AML) in tablets. The first method was based on the condensation reaction of AML with ninhydrin and phenylacetaldehyde in buffered medium (pH 7.0) resulting in formation of a green fluorescent product, which exhibits excitation and emission maxima at 375 and 480 nm, respectively. The second method was based on the reaction of AML with 7-chloro-4-nitro-2,1,3-benzoxadiazole (NBD-Cl) in a buffered medium (pH 8.6) resulting in formation of a highly fluorescent product, which was measured fluorometrically at 535 nm ( λex, 480 nm). The factors affecting the reactions were studied and optimized. Under the optimum reaction conditions, linear relationships with good correlation coefficients (0.9949-0.9997) were found between the fluorescence intensity and the concentrations of AML in the concentration range of 0.35-1.8 and 0.55-3.0 μg ml -1 for ninhydrin and NBD-Cl methods, respectively. The limits of assays detection were 0.09 and 0.16 μg ml -1 for the first and second method, respectively. The precisions of the methods were satisfactory; the relative standard deviations were ranged from 1.69 to 1.98%. The proposed methods were successfully applied to the analysis of AML in pure and pharmaceutical dosage forms with good accuracy; the recovery percentages ranged from 100.4-100.8 ± 1.70-2.32%. The results were compared favorably with those of the reported method.
Sperm proteasome and fertilization.
Sutovsky, Peter
2011-07-01
The omnipresent ubiquitin-proteasome system (UPS) is an ATP-dependent enzymatic machinery that targets substrate proteins for degradation by the 26S proteasome by tagging them with an isopeptide chain composed of covalently linked molecules of ubiquitin, a small chaperone protein. The current knowledge of UPS involvement in the process of sperm penetration through vitelline coat (VC) during human and animal fertilization is reviewed in this study, with attention also being given to sperm capacitation and acrosome reaction/exocytosis. In ascidians, spermatozoa release ubiquitin-activating and conjugating enzymes, proteasomes, and unconjugated ubiquitin to first ubiquitinate and then degrade the sperm receptor on the VC; in echinoderms and mammals, the VC (zona pellucida/ZP in mammals) is ubiquitinated during oogenesis and the sperm receptor degraded during fertilization. Various proteasomal subunits and associated enzymes have been detected in spermatozoa and localized to sperm acrosome and other sperm structures. By using specific fluorometric substrates, proteasome-specific proteolytic and deubiquitinating activities can be measured in live, intact spermatozoa and in sperm protein extracts. The requirement of proteasomal proteolysis during fertilization has been documented by the application of various proteasome-specific inhibitors and antibodies. A similar effect was achieved by depletion of sperm-surface ATP. Degradation of VC/ZP-associated sperm receptor proteins by sperm-borne proteasomes has been demonstrated in ascidians and sea urchins. On the applied side, polyspermy has been ameliorated by modulating sperm-associated deubiquitinating enzymes. Diagnostic and therapeutic applications could emerge in human reproductive medicine. Altogether, the studies on sperm proteasome indicate that animal fertilization is controlled in part by a unique, gamete associated, extracellular UPS.
Han, Hai; Miyoshi, Yurika; Ueno, Kyoko; Okamura, Chieko; Tojo, Yosuke; Mita, Masashi; Lindner, Wolfgang; Zaitsu, Kiyoshi; Hamase, Kenji
2011-11-01
For a metabolomics study focusing on the analysis of aspartic and glutamic acid enantiomers, a fully automated two-dimensional HPLC system employing a microbore-ODS column and a narrowbore-enantioselective column was developed. By using this system, a detailed distribution of D-Asp and D-Glu besides L-Asp and L-Glu in mammals was elucidated. For the total analysis concept, the amino acids were first pre-column derivatized with 4-fluoro-7-nitro-2,1,3-benzoxadiazole (NBD-F) to be sensitively and fluorometrically detected. For the non-stereoselective separation of the analytes in the first dimension a monolithic ODS column (750 mm × 0.53 mm i.d.) was adopted, and a self-packed narrowbore-Pirkle type enantioselective column (Sumichiral OA-2500S, 250 mm × 1.5 mm i.d.) was selected for the second dimension. In the rat plasma, RSD values for intra-day and inter-day precision were less than 6.8%, and the accuracy ranged between 96.1% and 105.8%. The values of LOQ of D-Asp and D-Glu were 5 fmol/injection (0.625 nmol/g tissue). The present method was successfully applied to the simultaneous determination of free aspartic acid and glutamic acid enantiomers in 7 brain areas, 11 peripheral tissues, plasma and urine of Wistar rats. Biologically significant D-Asp values were found in various tissue samples whereas for D-Glu the values were very low possibly indicating less significance. Copyright © 2011 Elsevier B.V. All rights reserved.
In vitro antineoplastic effects of auranofin in canine lymphoma cells.
Zhang, Hong; Rose, Barbara J; Pyuen, Alex A; Thamm, Douglas H
2018-05-03
The orally available gold complex auranofin (AF) has been used in humans, primarily as an antirheumatic/immunomodulatory agent. It has been safely administered to healthy dogs to establish pharmacokinetic parameters for oral administration, and has also been used as a treatment in some dogs with immune-mediated conditions. Multiple in vitro studies have recently suggested that AF may possess antineoplastic properties. Spontaneous canine lymphoma may be a very useful translational model for the study of human lymphoma, prompting the evaluation of AF in canine lymphoma cells. We investigated the antineoplastic activity of AF in 4 canine lymphoid tumor derived cell lines through measurements of proliferation, apoptosis, thioredoxin reductase (TrxR) activity and generation of reactive oxygen species (ROS), and detected the effects of AF when combined with conventional cytotoxic drugs using the Chou and Talalay method. We also evaluated the antiproliferative effects of AF in primary canine lymphoma cells using a bioreductive fluorometric assay. At concentrations that appear clinically achievable in humans, AF demonstrated potent antiproliferative and proapoptotic effects in canine lymphoid tumor cell lines. TrxR inhibition and increased ROS production was observed following AF treatment. Moreover, a synergistic antiproliferative effect was observed when AF was combined with lomustine or doxorubicin. Auranofin appears to inhibit the growth and initiate apoptosis in canine lymphoma cells in vitro at clinically achievable concentrations. Therefore, this agent has the potential to have near-term benefit for the treatment of canine lymphoma, as well as a translational model for human lymphoma. Decreased TrxR activity and increasing ROS production may be useful biomarkers of drug exposure.
Marcella, Aaron M; Barb, Adam W
The development of biorenewable chemicals will support green chemistry initiatives and supplement the catalog of starting materials available to the chemical industry. Bacterial fatty acid biosynthesis is being pursued as a source of protein catalysts to synthesize novel reduced carbon molecules in fermentation systems. The availability of methods to measure enzyme catalysis for native and engineered enzymes from this pathway remains a bottleneck because a simple quantitative enzyme assay for numerous enzymes does not exist. Here we present two variations of a fluorescence assay that is readily extendable to high-throughput screening and is appropriate for thiol consuming and generating enzymes including the Escherichia coli enzymes malonyl-coenzyme A transacylase (FabD) and keto-acylsynthase III (FabH). We measured K M values of 60 ± 20 µM (acetyl-CoA) and 20 ± 10 µM (malonyl-ACP) and a k cat of 7.4-9.0 s -1 with FabH. Assays of FabD included a precipitation step to remove the thiol-containing substrate holo-ACP from the reaction product coenzyme-A to estimate reaction rates. Analysis of initial velocity measurements revealed K M values of 60 ± 20 µM (malonyl-CoA) and 40 ± 10 µM (holo-ACP) and a k cat of 2100-2600 s -1 for the FabD enzyme. Our data show similar results when compared to existing radioactive and continuous coupled assays in terms of sensitivity while providing the benefit of simplicity, scalability and repeatability. Fluorescence detection also eliminates the need for radioactive substrates traditionally used to assay these enzymes.
Thani, Noor Azela Abdullah; Keshavarz, Sholeh; Lwaleed, Bashir A; Cooper, Alan J; Rooprai, Harcharan K
2014-11-01
Extending work with brain tumours, the hypothesis that micronutrients may usefully augment anticancer regimens, chokeberry (Aronia melanocarpa) extract was tested to establish whether it has pro-apoptotic effects in AsPC-1, an established human pancreatic cell line, and whether it potentiates cytotoxicity in combination with gemcitabine. Pancreatic cancer was chosen as a target, as its prognosis remains dismal despite advances in therapy. An MTT (3-(4,5-Dimethylthiazol-2-yl)-2,5-Diphenyltetrazolium Bromide) assay was used to assess the growth of the single pancreatic cancer cell line AsPC-1, alone and in comparison or combination with gemcitabine. This was backed up by flow cytometric DRAQ7 cell viability analysis. TUNEL assays were also carried out to investigate pro-apoptotic properties as responsible for the effects of chokeberry extract. Chokeberry extract alone and its IC75 value (1 µg/mL) in combination with gemcitabine were used to assess the growth of the AsPC-1 cell line. Gemcitabine in combination with chokeberry extract was more effective than gemcitabine alone. TUNEL assays showed apoptosis to be a mechanism occurring at 1 µg/mL concentration of chokeberry, with apoptotic bodies detected by both colourimetric and fluorometric methods. The implication of this study, using single cancer cell line, is that chemotherapy (at least with gemcitabine) might be usefully augmented with the use of micronutrients such as chokeberry extract. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Design-for-Hardware-Trust Techniques, Detection Strategies and Metrics for Hardware Trojans
2015-12-14
down both rising and falling transitions. For Trojan detection , one fault , slow-‐to-‐rise or slow-‐to...in Jan. 2016. Through the course of this project we developed novel hardware Trojan detection techniques based on clock sweeping. The technique takes...algorithms to detect minor changes due to Trojan and compared them with those changes made by process variations. This technique was implemented on
Procedure for flaw detection in cast stainless steel
Kupperman, David S.
1988-01-01
A method of ultrasonic flaw detection in cast stainless steel components incorporating the steps of determining the nature of the microstructure of the cast stainless steel at the site of the flaw detection measurements by ultrasonic elements independent of the component thickness at the site; choosing from a plurality of flaw detection techniques, one such technique appropriate to the nature of the microstructure as determined and detecting flaws by use of the chosen technique.
Ayas, Najib T.
2018-01-01
Epidemiological studies demonstrate an association between obstructive sleep apnea (OSA) and accelerated loss of kidney function. It is unclear whether the decline in function is due to OSA per se or to other confounding factors such as obesity. In addition, the structural kidney abnormalities associated with OSA are unclear. The objective of this study was to determine whether intermittent hypoxia (IH), a key pathological feature of OSA, induces renal histopathological damage using a mouse model. Ten 8-week old wild-type male CB57BL/6 mice were randomly assigned to receive either IH or intermittent air (IA) for 60 days. After euthanasia, one kidney per animal was paraformaldehyde-fixed and then sectioned for histopathological and immunohistochemical analysis. Measurements of glomerular hypertrophy and mesangial matrix expansion were made in periodic acid–Schiff stained kidney sections, while glomerular transforming growth factor-β1 (TGF-β1), connective tissue growth factor (CTGF) and vascular endothelial growth factor-A (VEGF-A) proteins were semi-quantified by immunohistochemistry. The antigen-antibody reaction was detected by 3,3′-diaminobenzidine chromogen where the color intensity semi-quantified glomerular protein expression. To enhance the accuracy of protein semi-quantification, the percentage of only highly-positive staining was used for analysis. Levels of TGF-β, CTGF and VEGF-A proteins in the kidney cortex were further quantified by western blotting. Cellular apoptosis was also investigated by measuring cortical antiapoptotic B-cell lymphoma 2 (Bcl-2) and apoptotic Bcl-2-associated X (Bax) proteins by western blotting. Further investigation of cellular apoptosis was carried out by fluorometric terminal deoxynucleotidyl transferase (TdT) dUTP Nick-End Labeling (TUNEL) staining. Finally, the levels of serum creatinine and 24-hour urinary albumin were measured as a general index of renal function. Our results indicate that mice exposed to IH have an increased glomerular area (by 1.13 fold, p< 0.001) and expansion of mesangial matrix (by 1.8 fold, p< 0.01). Moreover, the glomerular expressions of TGF-β1, CTGF and VEGF-A proteins were 2.7, 2.2 and 3.8-fold higher in mice exposed to IH (p< 0.05 for all). Furthermore, western blotting protein analysis demonstrates that IH-exposed mice express higher levels of TGF-β1, CTGF and VEGF-A proteins by 1.9, 4.0 and 1.6-fold (p< 0.05 for all) respectively. Renal cellular apoptosis was greater in the IH group as shown by an increased cortical Bax/Bcl-2 protein ratio (p< 0.01) and higher fluorometric TUNEL staining (p< 0.001). Finally, 24-hr urinary albumin levels were higher in mice exposed to IH (43.4 μg vs 9.7 μg, p< 0.01), while there were no differences in serum creatinine levels between the two groups. We conclude that IH causes kidney injury that is accompanied by glomerular hypertrophy, mesangial matrix expansion, increased expression of glomerular growth factors and an increased cellular apoptosis. PMID:29389945
A Novel Technique to Detect Code for SAC-OCDMA System
NASA Astrophysics Data System (ADS)
Bharti, Manisha; Kumar, Manoj; Sharma, Ajay K.
2018-04-01
The main task of optical code division multiple access (OCDMA) system is the detection of code used by a user in presence of multiple access interference (MAI). In this paper, new method of detection known as XOR subtraction detection for spectral amplitude coding OCDMA (SAC-OCDMA) based on double weight codes has been proposed and presented. As MAI is the main source of performance deterioration in OCDMA system, therefore, SAC technique is used in this paper to eliminate the effect of MAI up to a large extent. A comparative analysis is then made between the proposed scheme and other conventional detection schemes used like complimentary subtraction detection, AND subtraction detection and NAND subtraction detection. The system performance is characterized by Q-factor, BER and received optical power (ROP) with respect to input laser power and fiber length. The theoretical and simulation investigations reveal that the proposed detection technique provides better quality factor, security and received power in comparison to other conventional techniques. The wide opening of eye in case of proposed technique also proves its robustness.
Drop-Off Detection with the Long Cane: Effects of Different Cane Techniques on Performance
ERIC Educational Resources Information Center
Kim, Dae Shik; Emerson, Robert Wall; Curtis, Amy
2009-01-01
This study compared the drop-off detection performance with the two-point touch and constant contact cane techniques using a repeated-measures design with a convenience sample of 15 cane users with visual impairments. The constant contact technique was superior to the two-point touch technique in the drop-off detection rate and the 50% detection…
A Review of Financial Accounting Fraud Detection based on Data Mining Techniques
NASA Astrophysics Data System (ADS)
Sharma, Anuj; Kumar Panigrahi, Prabin
2012-02-01
With an upsurge in financial accounting fraud in the current economic scenario experienced, financial accounting fraud detection (FAFD) has become an emerging topic of great importance for academic, research and industries. The failure of internal auditing system of the organization in identifying the accounting frauds has lead to use of specialized procedures to detect financial accounting fraud, collective known as forensic accounting. Data mining techniques are providing great aid in financial accounting fraud detection, since dealing with the large data volumes and complexities of financial data are big challenges for forensic accounting. This paper presents a comprehensive review of the literature on the application of data mining techniques for the detection of financial accounting fraud and proposes a framework for data mining techniques based accounting fraud detection. The systematic and comprehensive literature review of the data mining techniques applicable to financial accounting fraud detection may provide a foundation to future research in this field. The findings of this review show that data mining techniques like logistic models, neural networks, Bayesian belief network, and decision trees have been applied most extensively to provide primary solutions to the problems inherent in the detection and classification of fraudulent data.
Kim, Dae Shik; Emerson, Robert S Wall; Curtis, Amy B
2010-06-01
This study examined the effect of cane tips and cane techniques on drop-off detection with the long cane. Blind pedestrians depend on a long cane to detect drop-offs. Missing a drop-off may result in falls or collision with moving vehicles in the street. Although cane tips appear to affect a cane user's ability to detect drop-offs, few experimental studies have examined such effect. A repeated-measures design with block randomization was used for the study. Participants were 17 adults who were legally blind and had no other disabilities. Participants attempted to detect the drop-offs of varied depths using different cane tips and cane techniques. Drop-off detection rates were similar between the marshmallow tip (77.0%) and the marshmallow roller tip (79.4%) when both tips were used with the constant contact technique, p = .294. However, participants detected drop-offs at a significantly higher percentage when they used the constant contact technique with the marshmallow roller tip (79.4%) than when they used the two-point touch technique with the marshmallow tip (63.2%), p < .001. The constant contact technique used with a marshmallow roller tip (perceived as a less advantageous tip) was more effective than the two-point touch technique used with a marshmallow tip (perceived as a more advantageous tip) in detecting drop-offs. The findings of the study may help cane users and orientation and mobility specialists select appropriate cane techniques and cane tips in accordance with the cane user's characteristics and the nature of the travel environment.
Allen, Robert C; John, Mallory G; Rutan, Sarah C; Filgueira, Marcelo R; Carr, Peter W
2012-09-07
A singular value decomposition-based background correction (SVD-BC) technique is proposed for the reduction of background contributions in online comprehensive two-dimensional liquid chromatography (LC×LC) data. The SVD-BC technique was compared to simply subtracting a blank chromatogram from a sample chromatogram and to a previously reported background correction technique for one dimensional chromatography, which uses an asymmetric weighted least squares (AWLS) approach. AWLS was the only background correction technique to completely remove the background artifacts from the samples as evaluated by visual inspection. However, the SVD-BC technique greatly reduced or eliminated the background artifacts as well and preserved the peak intensity better than AWLS. The loss in peak intensity by AWLS resulted in lower peak counts at the detection thresholds established using standards samples. However, the SVD-BC technique was found to introduce noise which led to detection of false peaks at the lower detection thresholds. As a result, the AWLS technique gave more precise peak counts than the SVD-BC technique, particularly at the lower detection thresholds. While the AWLS technique resulted in more consistent percent residual standard deviation values, a statistical improvement in peak quantification after background correction was not found regardless of the background correction technique used. Copyright © 2012 Elsevier B.V. All rights reserved.
Acoustic thermometry for detecting quenches in superconducting coils and conductor stacks
NASA Astrophysics Data System (ADS)
Marchevsky, M.; Gourlay, S. A.
2017-01-01
Quench detection capability is essential for reliable operation and protection of superconducting magnets, coils, cables, and machinery. We propose a quench detection technique based on sensing local temperature variations in the bulk of a superconducting winding by monitoring its transient acoustic response. Our approach is primarily aimed at coils and devices built with high-temperature superconductor materials where quench detection using standard voltage-based techniques may be inefficient due to the slow velocity of quench propagation. The acoustic sensing technique is non-invasive, fast, and capable of detecting temperature variations of less than 1 K in the interior of the superconductor cable stack in a 77 K cryogenic environment. We show results of finite element modeling and experiments conducted on a model superconductor stack demonstrating viability of the technique for practical quench detection, discuss sensitivity limits of the technique, and its various applications.
Synthesis and Characterization of Iron Doped Nano Barium Titanate Through Mechanochemical Route
NASA Astrophysics Data System (ADS)
Mukherjee, Soumya; Ghosh, S.; Ghosh, C.; Mitra, M. K.
2013-04-01
Mechanochemical activation was used to prepare Fe doped barium titanate with intense milling in high energy planetary ball mill. Calcination was done at 1250°C for 30 min to obtain BaO, followed by milling with titania, at 400 rpm for 3 and 6 h. Ferric oxide was used for Fe doping. Annealing was done on the milled sample at 650, 750 and 850 °C for 3 and 6 h to generate stoichiometric compound of barium titanate phase. Fe doped barium titanate results in dense cluster of irregular polygonal shape morphology while morphology was spherical in nature for undoped sample. UV-VIS spectra analysis was carried out to determine bandgap (3.93 eV for undoped BT and 3.88 eV for Fe doped BT) followed by emission-excitation of the sample by fluorometric analysis.
Fernández-Sierra, Mónica; Quiñones, Edwin
2015-03-15
Here we characterize the fluorescence of the YOYO dye as a tool for studying DNA-protein interactions in real time and present two continuous YOYO-based assays for sensitively monitoring the kinetics of DNA digestion by λ-exonuclease and the endonuclease EcoRV. The described assays rely on the different fluorescence intensities between single- and double-stranded DNA-YOYO complexes, allowing straightforward determination of nuclease activity and quantitative determination of reaction products. The assays were also employed to assess the effect of single-stranded DNA-binding proteins on the λ-exonuclease reaction kinetics, showing that the extreme thermostable single-stranded DNA-binding protein (ET-SSB) significantly reduced the reaction rate, while the recombination protein A (RecA) displayed no effect. Copyright © 2015 Elsevier Inc. All rights reserved.
Wang, E T; Zhou, D R; He, L H
1992-07-01
The blood levels of histamine and 5-hydroxytryptamine (5-HT) in 10 subjects, with or without administration of the transdermal therapeutic system of scopolamine (TTS-S), were measured following motion sickness (MS) induced by Coriolis stimulation. Histamine and 5-HT were assayed using the fluorometric method. The results demonstrated that the blood levels of histamine increased significantly following MS and were even higher in the subjects using TTS-S, but we found neither significant changes in the blood levels of 5-HT following MS nor any effect of TTS-S on it. The results suggest that histamine contributes to the development of MS, and scopolamine may exert its anti-MS action by affecting the histaminergic system as well as the acetylcholinergic system; there may not be a definite relation between 5-HT and the development of MS.
Yoon, Bora; Park, In Sung; Shin, Hyora; Park, Hye Jin; Lee, Chan Woo; Kim, Jong-Man
2013-05-14
Inkjet-printed paper-based volatile organic compound (VOC) sensor strips imaged with polydiacetylenes (PDAs) are developed. A microemulsion ink containing bisurethane-substituted diacetylene (DA) monomers, 4BCMU, was inkjet printed onto paper using a conventional inkjet office printer. UV irradiation of the printed image allowed fabrication of blue-colored poly-4BCMU on the paper and the polymer was found to display colorimetric responses to VOCs. Interestingly, a blue-to-yellow color change was observed when the strip was exposed to chloroform vapor, which was accompanied by the generation of green fluorescence. The principal component analysis plot of the color and fluorescence images of the VOC-exposed polymers allowed a more precise discrimination of VOC vapors. Copyright © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Remote sensing of chlorophyll concentrations in the northern Gulf of Mexico
NASA Technical Reports Server (NTRS)
Trees, Charles C.; El-Sayed, Sayed Z.
1986-01-01
During a 17 month period (November 1978 - March 1980), phytoplankton pigment concentrations were remotely sensed in the northern Gulf of Mexico using the Coastal Zone Color Scanner (CZCS). A total of 29 CZCS orbits were processed into pigment (chlorophyll a + phaeopigments) images and then geometrically warped to a Mercator projection. A correction factor of 1.67 was applied to the pigment concentrations to correct for the tendency of the standard fluorometric method to underestimate chlorophyll a concentrations. The spatial and temporal distributions of pigment fronts were quite variable during this time series. Constant features observed throughout the pigment imagery were the entrainment of coastal waters offshore. The most extensive entrainments occurred during intrusions of the Loop Current. For the 17 month survey, the mean HPLC-corrected pigment concentration was 3.30 + or - 1.45 mg/cu m.
Taner, Bilge; Kursunlu, Ahmed Nuri; Güler, Ersin
2014-01-24
A novel chemosensor based on calix[4]pyrrole derivative modified by Bodipy unit has been synthesized, and its complexes with various anions were investigated. The results show that the receptors can selectively recognize biologically important fluoride ions. The binding affinity for fluoride ions was investigated by naked-eye color change, absorption, emission, proton nuclear magnetic resonance spectroscopy. The addition of fluoride ions to an acetonitrile solution of chemosensor can result in an obvious color change (brownish yellow color to straw yellow). The stoichiometries between the receptor and fluoride were determined from the molar ratio plots using the UV-visible spectra, which showed evident 1:1. The proton nuclear magnetic resonance spectral data supported the fluoride anion recognition with the disappearance of the amino proton peaks. Published by Elsevier B.V.
A novel fiber optic sensor for the measurement of pH of blood based on colorimetry
NASA Astrophysics Data System (ADS)
Chaudhari, A. L.; Patil, D. D.; Shaligram, Arvind D.
2005-04-01
Fiber optic sensors designed to the date are largely based on monitoring the absorption change of several immobilized indicators or change in fluorescence of fluorometric indicators. The present paper reports a new type of fiber optic sensor for the measurement of blood pH based on Colorimetric principle. The sensor consists of two multimode step index fibers, mirror as reflector and blood serum with universal indicator as medium. LED is used as source and photodiode as detector. The intensity of color produced due to addition of indicator to blood serum depends upon hydrogen ion concentration. The output intensity from receiving fiber is measured as a function of pH of blood. The developed sensor is calibrated against the standard pH meter. The design, construction and calibration details are presented in paper.
Selectivity/Specificity Improvement Strategies in Surface-Enhanced Raman Spectroscopy Analysis
Wang, Feng; Cao, Shiyu; Yan, Ruxia; Wang, Zewei; Wang, Dan; Yang, Haifeng
2017-01-01
Surface-enhanced Raman spectroscopy (SERS) is a powerful technique for the discrimination, identification, and potential quantification of certain compounds/organisms. However, its real application is challenging due to the multiple interference from the complicated detection matrix. Therefore, selective/specific detection is crucial for the real application of SERS technique. We summarize in this review five selective/specific detection techniques (chemical reaction, antibody, aptamer, molecularly imprinted polymers and microfluidics), which can be applied for the rapid and reliable selective/specific detection when coupled with SERS technique. PMID:29160798
Edge detection techniques for iris recognition system
NASA Astrophysics Data System (ADS)
Tania, U. T.; Motakabber, S. M. A.; Ibrahimy, M. I.
2013-12-01
Nowadays security and authentication are the major parts of our daily life. Iris is one of the most reliable organ or part of human body which can be used for identification and authentication purpose. To develop an iris authentication algorithm for personal identification, this paper examines two edge detection techniques for iris recognition system. Between the Sobel and the Canny edge detection techniques, the experimental result shows that the Canny's technique has better ability to detect points in a digital image where image gray level changes even at slow rate.
Antibody detection tests improve the sensitivity of tuberculosis diagnosis in cattle.
Casal, C; Infantes, J A; Risalde, M A; Díez-Guerrier, A; Domínguez, M; Moreno, I; Romero, B; de Juan, L; Sáez, J L; Juste, R; Gortázar, C; Domínguez, L; Bezos, J
2017-06-01
We evaluated the sensitivity (Se) of the single cervical intradermal tuberculin (SIT) test, two interferon-gamma (IFN-γ) assays and three different antibody detection techniques for bovine tuberculosis (bTB) diagnosis in 131 mixed beef breed cattle. The results of the diagnostic techniques performed over the whole herd, and over the animals confirmed as infected based on the presence of lesions compatible with the disease and/or M. bovis isolation were compared to determine apparent prevalence (AP) and Se. The Se of the SIT test (severe interpretation) was 63.7% (95% CI, 54.54-72.00), while the Se of the IFN-γ assays ranged between 60.2% and 92%. The proportion of infected cattle detected by the different antibody detection techniques ranged from 65.5% to 87.6%. Three of the antibody detection techniques yielded a significant higher (p<0.05) Se than that achieved with the official diagnostic techniques. In addition, the interpretation in parallel of cellular and antibody detection techniques reached the highest Se: 98.2% (95% CI, 93.78-99.51) suggesting that the use of diagnostic techniques detecting both cellular and humoral responses could be considered as an alternative in the control of bTB outbreaks in high prevalence settings. Copyright © 2017 Elsevier Ltd. All rights reserved.
A new method for QRS detection in ECG signals using QRS-preserving filtering techniques.
Sharma, Tanushree; Sharma, Kamalesh K
2018-03-28
Detection of QRS complexes in ECG signals is required for various purposes such as determination of heart rate, feature extraction and classification. The problem of automatic QRS detection in ECG signals is complicated by the presence of noise spectrally overlapping with the QRS frequency range. As a solution to this problem, we propose the use of least-squares-optimisation-based smoothing techniques that suppress the noise peaks in the ECG while preserving the QRS complexes. We also propose a novel nonlinear transformation technique that is applied after the smoothing operations, which equalises the QRS amplitudes without boosting the supressed noise peaks. After these preprocessing operations, the R-peaks can finally be detected with high accuracy. The proposed technique has a low computational load and, therefore, it can be used for real-time QRS detection in a wearable device such as a Holter monitor or for fast offline QRS detection. The offline and real-time versions of the proposed technique have been evaluated on the standard MIT-BIH database. The offline implementation is found to perform better than state-of-the-art techniques based on wavelet transforms, empirical mode decomposition, etc. and the real-time implementation also shows improved performance over existing real-time QRS detection techniques.
Protecting against cyber threats in networked information systems
NASA Astrophysics Data System (ADS)
Ertoz, Levent; Lazarevic, Aleksandar; Eilertson, Eric; Tan, Pang-Ning; Dokas, Paul; Kumar, Vipin; Srivastava, Jaideep
2003-07-01
This paper provides an overview of our efforts in detecting cyber attacks in networked information systems. Traditional signature based techniques for detecting cyber attacks can only detect previously known intrusions and are useless against novel attacks and emerging threats. Our current research at the University of Minnesota is focused on developing data mining techniques to automatically detect attacks against computer networks and systems. This research is being conducted as a part of MINDS (Minnesota Intrusion Detection System) project at the University of Minnesota. Experimental results on live network traffic at the University of Minnesota show that the new techniques show great promise in detecting novel intrusions. In particular, during the past few months our techniques have been successful in automatically identifying several novel intrusions that could not be detected using state-of-the-art tools such as SNORT.
NASA Astrophysics Data System (ADS)
Chandramouli, Rajarathnam; Li, Grace; Memon, Nasir D.
2002-04-01
Steganalysis techniques attempt to differentiate between stego-objects and cover-objects. In recent work we developed an explicit analytic upper bound for the steganographic capacity of LSB based steganographic techniques for a given false probability of detection. In this paper we look at adaptive steganographic techniques. Adaptive steganographic techniques take explicit steps to escape detection. We explore different techniques that can be used to adapt message embedding to the image content or to a known steganalysis technique. We investigate the advantages of adaptive steganography within an analytical framework. We also give experimental results with a state-of-the-art steganalysis technique demonstrating that adaptive embedding results in a significant number of bits embedded without detection.
Kim, Dae Shik; Wall Emerson, Robert S.; Curtis, Amy B.
2010-01-01
Objective This study examined the effect of cane tips and cane techniques on drop-off detection with the long cane. Background Blind pedestrians depend on a long cane to detect drop-offs. Missing a drop-off may result in falls or collision with moving vehicles in the street. Although cane tips appear to affect a cane user’s ability to detect drop-offs, few experimental studies have examined such effect. Method A repeated-measures design with block randomization was used for the study. Participants were 17 adults who were legally blind and had no other disabilities. Participants attempted to detect the drop-offs of varied depths using different cane tips and cane techniques. Results Drop-off detection rates were similar between the marshmallow tip (77.0%) and the marshmallow roller tip (79.4%) when both tips were used with the constant contact technique, p = .294. However, participants detected drop-offs at a significantly higher percentage when they used the constant contact technique with the marshmallow roller tip (79.4%) than when they used the two-point touch technique with the marshmallow tip (63.2%), p < .001. Conclusion The constant contact technique used with a marshmallow roller tip (perceived as a less advantageous tip) was more effective than the two-point touch technique used with a marshmallow tip (perceived as a more advantageous tip) in detecting drop-offs. Application The findings of the study may help cane users and orientation and mobility specialists select appropriate cane techniques and cane tips in accordance with the cane user’s characteristics and the nature of the travel environment. PMID:21077566
Advanced endoscopic imaging to improve adenoma detection
Neumann, Helmut; Nägel, Andreas; Buda, Andrea
2015-01-01
Advanced endoscopic imaging is revolutionizing our way on how to diagnose and treat colorectal lesions. Within recent years a variety of modern endoscopic imaging techniques was introduced to improve adenoma detection rates. Those include high-definition imaging, dye-less chromoendoscopy techniques and novel, highly flexible endoscopes, some of them equipped with balloons or multiple lenses in order to improve adenoma detection rates. In this review we will focus on the newest developments in the field of colonoscopic imaging to improve adenoma detection rates. Described techniques include high-definition imaging, optical chromoendoscopy techniques, virtual chromoendoscopy techniques, the Third Eye Retroscope and other retroviewing devices, the G-EYE endoscope and the Full Spectrum Endoscopy-system. PMID:25789092
Ambient air contamination: Characterization and detection techniques
NASA Technical Reports Server (NTRS)
Nulton, C. P.; Silvus, H. S.
1985-01-01
Techniques to characterize and detect sources of ambient air contamination are described. Chemical techniques to identify indoor contaminants are outlined, they include gas chromatography, or colorimetric detection. Organics generated from indoor materials at ambient conditions and upon combustion are characterized. Piezoelectric quartz crystals are used as precision frequency determining elements in electronic oscillators.
[Progress of study on the detection technique of microRNA].
Zhao, Hai-Feng; Yang, Ren-Chi
2009-12-01
MicroRNAs (miRNAs) are small noncoding RNA molecules that negatively regulate gene expression via degradation or translational repression of their targeted mRNAs. MiRNAs are involved in critical biologic processes, including development, cell differentiation, proliferation and the pathogenesis of disease. This review focuses on recent researches on the detection techniques of miRNA including micorarray technique, Northern blot, real-time quantitative PCR, detection technique of miRNA function and so on.
DNA integrity determination in marine invertebrates by Fast Micromethod.
Jaksić, Zeljko; Batel, Renato
2003-12-10
This study was focused toward the adaptation of the previously developed Fast Micromethod for DNA damage determination to marine invertebrates for the establishment of biomonitoring assessment. The Fast Micromethod detects DNA damage (strand breaks, alkali-labile sites and incomplete excision repair) and determines DNA integrity in cell suspensions or tissue homogenates in single microplates. The procedure is based on the ability of the specific fluorochrome dye PicoGreen to preferentially interact with high integrity DNA molecules, dsDNA, in the presence of ssDNA and proteins in high alkaline medium, thereby allowing direct fluorometric measurements of dsDNA denaturation without sample handling and stepwise DNA separations. The results presented herein describe the influence of the DNA amount and the pH of the denaturation media on slopes of the kinetic denaturation curves and calculated strand scission factors (SSFs). The optimal amount of DNA in Mytilus galloprovincialis gills homogenate was found to be 100 ng ml(-1) and the greatest differences in DNA unwinding kinetics (slopes and SSF values) were reached at pH 11.5. The induction of DNA damage and loss of DNA integrity was measured in native DNA isolated from cotton-spinner Holothuria tubulosa, marine sponge Suberites domuncula cells and mussel M. galloprovincialis gills homogenate. DNA damage and loss of DNA integrity were detected after induction by different doses of (gamma-rays, generated by 137Cs 1800 Ci; 0-500 rad in marine sponge S. domuncula cells up to SSFx(-1) values 0.082 +/- 0.012 for the highest radiation dose). Analysis by chemical xenobiotics based on the in vitro action of bleomycin (bleomycin-Fe(II) complex 0-50 or 0-83 microg ml(-1) (microM)) with native DNA from cotton-spinner H. tubulosa and mussel M. galloprovincialis gills homogenate yielded values of 0.537 +/- 0.072 and 0.130 +/- 0.018, respectively. In vivo experiments with mussel M. galloprovincialis gills homogenate by 4-nitroquinoline-N-oxide (NQO; 0-1 microg g(-1) NQO mussel) and benzo[a]pyrene (B[a]P; 0-20 microg g(-1) B[a]P mussel) indicated SSFx(-1) values of 0.121 +/- 0.016 and 0.090 +/- 0.007, respectively, for the highest applied doses of chemical xenobiotics. The analytical technique described here allows simple and fast analysis of DNA integrity, requires very short time for multiple analyses (less than 3 h) and even less than 100 ng DNA per single well (50 ng DNA isolated from cotton-spinner, 12,500 sponge cells or about 10 mg of mussel gills homogenate) in a microplate. This makes the Fast Micromethod applicable for the measurement of DNA integrity of small samples for genotoxicity assessment (biomonitoring), the effects of genotoxins on lower marine taxa or sessile invertebrates in marine environment (e.g. sponges, mussels) and the estimation of directional changes and harmful effects in the ecosystem.
NASA Astrophysics Data System (ADS)
Zhang, Huibin; Wang, Yuqiao; Chen, Haoran; Zhao, Yongli; Zhang, Jie
2017-12-01
In software defined optical networks (SDON), the centralized control plane may encounter numerous intrusion threatens which compromise the security level of provisioned services. In this paper, the issue of control plane security is studied and two machine-learning-based control plane intrusion detection techniques are proposed for SDON with properly selected features such as bandwidth, route length, etc. We validate the feasibility and efficiency of the proposed techniques by simulations. Results show an accuracy of 83% for intrusion detection can be achieved with the proposed machine-learning-based control plane intrusion detection techniques.
Search Radar Track-Before-Detect Using the Hough Transform.
1995-03-01
before - detect processing method which allows previous data to help in target detection. The technique provides many advantages compared to...improved target detection scheme, applicable to search radars, using the Hough transform image processing technique. The system concept involves a track
Qualitative and quantitative detection of T7 bacteriophages using paper based sandwich ELISA.
Khan, Mohidus Samad; Pande, Tripti; van de Ven, Theo G M
2015-08-01
Viruses cause many infectious diseases and consequently epidemic health threats. Paper based diagnostics and filters can offer attractive options for detecting and deactivating pathogens. However, due to their infectious characteristics, virus detection using paper diagnostics is more challenging compared to the detection of bacteria, enzymes, DNA or antigens. The major objective of this study was to prepare reliable, degradable and low cost paper diagnostics to detect viruses, without using sophisticated optical or microfluidic analytical instruments. T7 bacteriophage was used as a model virus. A paper based sandwich ELISA technique was developed to detect and quantify the T7 phages in solution. The paper based sandwich ELISA detected T7 phage concentrations as low as 100 pfu/mL to as high as 10(9) pfu/mL. The compatibility of paper based sandwich ELISA with the conventional titre count was tested using T7 phage solutions of unknown concentrations. The paper based sandwich ELISA technique is faster and economical compared to the traditional detection techniques. Therefore, with proper calibration and right reagents, and by following the biosafety regulations, the paper based technique can be said to be compatible and economical to the sophisticated laboratory diagnostic techniques applied to detect pathogenic viruses and other microorganisms. Copyright © 2015 Elsevier B.V. All rights reserved.
Fluorescence hyperspectral imaging technique for foreign substance detection on fresh-cut lettuce.
Mo, Changyeun; Kim, Giyoung; Kim, Moon S; Lim, Jongguk; Cho, Hyunjeong; Barnaby, Jinyoung Yang; Cho, Byoung-Kwan
2017-09-01
Non-destructive methods based on fluorescence hyperspectral imaging (HSI) techniques were developed to detect worms on fresh-cut lettuce. The optimal wavebands for detecting the worms were investigated using the one-way ANOVA and correlation analyses. The worm detection imaging algorithms, RSI-I (492-626)/492 , provided a prediction accuracy of 99.0%. The fluorescence HSI techniques indicated that the spectral images with a pixel size of 1 × 1 mm had the best classification accuracy for worms. The overall results demonstrate that fluorescence HSI techniques have the potential to detect worms on fresh-cut lettuce. In the future, we will focus on developing a multi-spectral imaging system to detect foreign substances such as worms, slugs and earthworms on fresh-cut lettuce. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.
NASA Technical Reports Server (NTRS)
Wolf, J. A.
1978-01-01
The Highly maneuverable aircraft technology (HIMAT) remotely piloted research vehicle (RPRV) uses cross-ship comparison monitoring of the actuator RAM positions to detect a failure in the aileron, canard, and elevator control surface servosystems. Some possible sources of nuisance trips for this failure detection technique are analyzed. A FORTRAN model of the simplex servosystems and the failure detection technique were utilized to provide a convenient means of changing parameters and introducing system noise. The sensitivity of the technique to differences between servosystems and operating conditions was determined. The cross-ship comparison monitoring method presently appears to be marginal in its capability to detect an actual failure and to withstand nuisance trips.
Kubota, Shunsuke; Kurihara, Toshihide; Mochimaru, Hiroshi; Satofuka, Shingo; Noda, Kousuke; Ozawa, Yoko; Oike, Yuichi; Ishida, Susumu; Tsubota, Kazuo
2009-07-01
Resveratrol is known as one of the antioxidant polyphenols contained in red wine and grape skin. The purpose of the present study was to investigate the role of resveratrol in ocular inflammation in endotoxin-induced uveitis (EIU). EIU was induced in male C57/B6 mice at the age of 6 weeks by a single intraperitoneal injection of lipopolysaccharide (LPS). Animals had received oral supplementation of resveratrol at the doses of 5, 50, 100, or 200 mg/kg for 5 days until LPS injection. Twenty-four hours after LPS administration, leukocyte adhesion to the retinal vasculature was examined with a concanavalin A lectin perfusion-labeling technique. Retinal and retinal pigment epithelium (RPE)-choroidal levels of intercellular adhesion molecule (ICAM)-1, monocyte chemotactic protein (MCP)-1, and 8-hydroxy-2'-deoxyguanosine (8-OHdG) and nuclear translocation of nuclear factor (NF)-kappaB p65 were evaluated by enzyme-linked immunosorbent assay. Retinal and RPE-choroidal activities of silent information regulator two ortholog (SIRT) 1 were measured by deacetylase fluorometric assay. Resveratrol pretreatment led to significant and dose-dependent suppression of leukocyte adhesion to retinal vessels of EIU mice compared with vehicle application. Protein levels of MCP-1 and ICAM-1 in the retina and the RPE-choroid of EIU animals were significantly reduced by resveratrol administration. Importantly, resveratrol-treated animals showed significant decline of retinal 8-OHdG generation and nuclear NF-kappaB P65 translocation, both of which were upregulated after EIU induction. RPE-choroidal SIRT1 activity, reduced in EIU animals, was significantly augmented by treatment with resveratrol. Resveratrol prevented EIU-associated cellular and molecular inflammatory responses by inhibiting oxidative damage and redox-sensitive NF-kappaB activation.
Panizo, A; Pardo, J; Hernández, M; Galindo, M F; Cenarruzabeitia, E; Díez, J
1995-08-01
In genetic and acquired hypertension, a structural remodeling of the nonmyocyte compartment of myocardium, including the accumulation of fibrillar collagen and other components of the extracellular matrix (ECM) within the interstitium, represents a determinant of pathologic hypertrophy that leads to ventricular dysfunction. Therefore, to evaluate the potential benefit of the angiotensin converting enzyme (ACE) inhibitor quinapril in reversing the interstitial remodeling in spontaneously hypertensive rats (SHR) with established left ventricular hypertrophy (LVH), we treated 16-week-old male SHR with oral quinapril (average dose, 10 mg/kg body weight/day) for 20 weeks. Interstitial fibrosis was determined morphometrically using an automatic image analyzer. The amount of collagen was evaluated by measuring myocardial hydroxyproline concentration. Myocardial deposition of collagen molecules (types I, III, and IV) and other ECM components (fibronectin, laminin) was analyzed by immunohistochemical techniques using specific monoclonal antibodies. The activity of ACE was measured in left ventricular tissue by a fluorometric assay. In quinapril-treated SHR compared with 36-week-old untreated SHR and age- and sex-matched Wistar-Kyoto (WKY) controls, we found 1) a lesser degree of LVH and a lesser level of blood pressure, 2) a lesser degree of interstitial fibrosis, represented by less interstitial collagen volume fraction (5.73 +/- 0.45% v 3.42 +/- 0.28%, P < .05; WKY, 3.44 +/- 0.66%), 3) a lower hydroxyproline concentration (1.09 +/- 0.05 mumol/L/g dry weight/100 g body weight to 0.81 +/- 0.05 mumol/L/g dry weight/100 g body weight, P < .05; WKY, 0.96 +/- 0.06 mumol/L/g dry weight/100 g body weight), 4) a lesser presence of collagen fibers, and 5) a lesser presence of collagen IV, fibronectin, and laminin.(ABSTRACT TRUNCATED AT 250 WORDS)
Mady, Fatma M; Shaker, Mohamed A
2017-01-01
Despite the fact that various studies have investigated the clinical relevance of ellagic acid (EA) as a naturally existing bioactive substance in cancer therapy, little has been reported regarding the efficient strategy for improving its oral bioavailability. In this study, we report the formulation of EA-loaded nanoparticles (EA-NPs) to find a way to enhance its bioactivity as well as bioavailability after oral administration. Poly(ε-caprolactone) (PCL) was selected as the biodegradable polymer for the formulation of EA-NPs through the emulsion-diffusion-evaporation technique. The obtained NPs have been characterized by measuring particle size, zeta potential, Fourier transform infrared, differential scanning calorimetry, and X-ray diffraction. The entrapment efficiency and the release profile of EA was also determined. In vitro cellular uptake and cytotoxicity of the obtained NPs were evaluated using Caco-2 and HCT-116 cell lines, respectively. Moreover, in vivo study has been performed to measure the oral bioavailability of EA-NPs compared to free EA, using New Zealand white rabbits. NPs with distinct shape were obtained with high entrapment and loading efficiencies. Diffusion-driven release profile of EA from the prepared NPs was determined. EA-NP-treated HCT-116 cells showed relatively lower cell viability compared to free EA-treated cells. Fluorometric imaging revealed the cellular uptake and efficient localization of EA-NPs in the nuclear region of Caco-2 cells. In vivo testing revealed that the oral administration of EA-NPs produced a 3.6 times increase in the area under the curve compared to that of EA. From these results, it can be concluded that incorporation of EA into PCL as NPs enhances its oral bioavailability and activity.
Mady, Fatma M; Shaker, Mohamed A
2017-01-01
Despite the fact that various studies have investigated the clinical relevance of ellagic acid (EA) as a naturally existing bioactive substance in cancer therapy, little has been reported regarding the efficient strategy for improving its oral bioavailability. In this study, we report the formulation of EA-loaded nanoparticles (EA-NPs) to find a way to enhance its bioactivity as well as bioavailability after oral administration. Poly(ε-caprolactone) (PCL) was selected as the biodegradable polymer for the formulation of EA-NPs through the emulsion–diffusion–evaporation technique. The obtained NPs have been characterized by measuring particle size, zeta potential, Fourier transform infrared, differential scanning calorimetry, and X-ray diffraction. The entrapment efficiency and the release profile of EA was also determined. In vitro cellular uptake and cytotoxicity of the obtained NPs were evaluated using Caco-2 and HCT-116 cell lines, respectively. Moreover, in vivo study has been performed to measure the oral bioavailability of EA-NPs compared to free EA, using New Zealand white rabbits. NPs with distinct shape were obtained with high entrapment and loading efficiencies. Diffusion-driven release profile of EA from the prepared NPs was determined. EA-NP-treated HCT-116 cells showed relatively lower cell viability compared to free EA-treated cells. Fluorometric imaging revealed the cellular uptake and efficient localization of EA-NPs in the nuclear region of Caco-2 cells. In vivo testing revealed that the oral administration of EA-NPs produced a 3.6 times increase in the area under the curve compared to that of EA. From these results, it can be concluded that incorporation of EA into PCL as NPs enhances its oral bioavailability and activity. PMID:29066891
TNFα enhances force generation in airway smooth muscle
Han, Young-Soo; Delmotte, Philippe
2017-01-01
Airway inflammation is a hallmark of asthma, triggering airway smooth muscle (ASM) hyperreactivity and airway remodeling. TNFα increases both agonist-induced cytosolic Ca2+ concentration ([Ca2+]cyt) and force in ASM. The effects of TNFα on ASM force may also be due to an increase in Ca2+ sensitivity, cytoskeletal remodeling, and/or changes in contractile protein content. We hypothesized that 24 h of exposure to TNFα increases ASM force by changing actin and myosin heavy chain (MyHC) content and/or polymerization. Porcine ASM strips were permeabilized with 10% Triton X-100, and force was measured in response to increasing concentrations of Ca2+ (pCa 9.0 to 4.0) in control and TNFα-treated groups. Relative phosphorylation of the regulatory myosin light chain (p-MLC) and total actin, MLC, and MyHC concentrations were quantified at pCa 9.0, 6.1, and 4.0. Actin polymerization was quantified by the ratio of filamentous to globular actin at pCa 9.0 and 4.0. For determination of total cross-bridge formation, isometric ATP hydrolysis rate at pCa 4.0 was measured using an enzyme-coupled NADH-linked fluorometric technique. Exposure to TNFα significantly increased force across the range of Ca2+ activation but did not affect the intrinsic Ca2+ sensitivity of force generation. The TNFα-induced increase in ASM force was associated with an increase in total actin, MLC, and MyHC content, as well as an increase in actin polymerization and an increase in maximum isometric ATP hydrolysis rate. The results of this study support our hypothesis that TNFα increases force generation in ASM by increasing the number of contractile units (actin-myosin content) contributing to force generation. PMID:28385814
Griffin, Matt J.; Quiniou, Sylvie M.; Cody, Theresa; Tabuchi, Maki; Ware, Cynthia; Cipriano, Rocco C.; Mauel, Michael J.; Soto, Esteban
2013-01-01
Edwardsiella tarda, a Gram-negative member of the family Enterobacteriaceae, has been implicated in significant losses in aquaculture facilities worldwide. Here, we assessed the intra-specific variability of E. tarda isolates from 4 different fish species in the eastern United States. Repetitive sequence mediated PCR (rep-PCR) using 4 different primer sets (ERIC I & II, ERIC II, BOX, and GTG5) and multi-locus sequence analysis of 16S SSU rDNA, groEl, gyrA, gyrB, pho, pgi, pgm, and rpoA gene fragments identified two distinct genotypes of E. tarda (DNA group I; DNA group II). Isolates that fell into DNA group II demonstrated more similarity to E. ictaluri than DNA group I, which contained the reference E. tarda strain (ATCC #15947). Conventional PCR analysis using published E. tarda-specific primer sets yielded variable results, with several primer sets producing no observable amplification of target DNA from some isolates. Fluorometric determination of G + C content demonstrated 56.4% G + C content for DNA group I, 60.2% for DNA group II, and 58.4% for E. ictaluri. Surprisingly, these isolates were indistinguishable using conventional biochemical techniques, with all isolates demonstrating phenotypic characteristics consistent with E. tarda. Analysis using two commercial test kits identified multiple phenotypes, although no single metabolic characteristic could reliably discriminate between genetic groups. Additionally, anti-microbial susceptibility and fatty acid profiles did not demonstrate remarkable differences between groups. The significant genetic variation (<90% similarity at gyrA, gyrB, pho, phi and pgm; <40% similarity by rep-PCR) between these groups suggests organisms from DNA group II may represent an unrecognized, genetically distinct taxa of Edwardsiella that is phenotypically indistinguishable from E. tarda.
Rapid upregulation of GLUT-4 and MCT-4 expression during 16 h of heavy intermittent cycle exercise.
Green, H J; Duhamel, T A; Holloway, G P; Moule, J W; Ranney, D W; Tupling, A R; Ouyang, J
2008-02-01
In this study, we have investigated the hypothesis that an exercise protocol designed to repeatedly induce a large dependence on carbohydrate and large increases in glycolytic flux rate would result in rapid increases in the principal glucose and lactate transporters in working muscle, glucose transporter (GLUT)-4 and monocarboxylate transporter (MCT)4, respectively, and in activity of hexokinase (Hex), the enzyme used to phosphorylate glucose. Transporter abundance and Hex activity were assessed in homogenates by Western blotting and quantitative chemiluminescence and fluorometric techniques, respectively, in samples of tissue obtained from the vastus lateralis in 12 untrained volunteers [peak aerobic power (.VO(2peak)) = 44.3 +/- 2.3 ml.kg(-1).min(-1)] before cycle exercise at repetitions 1 (R1), 2 (R2), 9 (R9), and 16 (R16). The 16 repetitions of the exercise were performed for 6 min at approximately 90% .VO(2peak), once per hour. Compared with R1, GLUT-4 increased (P < 0.05) by 28% at R2 and remained elevated (P < 0.05) at R9 and R16. For MCT-4, increases (P < 0.05) of 24% were first observed at R9 and persisted at R16. No changes were observed in GLUT-1 and MCT-1 or in Hex activity. The approximately 17- to 24-fold increase (P < 0.05) in muscle lactate observed at R1 and R2 was reduced (P < 0.05) to an 11-fold increase at R9 and R16. It is concluded that an exercise protocol designed to strain muscle carbohydrate reserves and to result in large increases in lactic acid results in a rapid upregulation of both GLUT-4 and MCT-4.
Electrocardiographic signals and swarm-based support vector machine for hypoglycemia detection.
Nuryani, Nuryani; Ling, Steve S H; Nguyen, H T
2012-04-01
Cardiac arrhythmia relating to hypoglycemia is suggested as a cause of death in diabetic patients. This article introduces electrocardiographic (ECG) parameters for artificially induced hypoglycemia detection. In addition, a hybrid technique of swarm-based support vector machine (SVM) is introduced for hypoglycemia detection using the ECG parameters as inputs. In this technique, a particle swarm optimization (PSO) is proposed to optimize the SVM to detect hypoglycemia. In an experiment using medical data of patients with Type 1 diabetes, the introduced ECG parameters show significant contributions to the performance of the hypoglycemia detection and the proposed detection technique performs well in terms of sensitivity and specificity.
Building Change Detection from LIDAR Point Cloud Data Based on Connected Component Analysis
NASA Astrophysics Data System (ADS)
Awrangjeb, M.; Fraser, C. S.; Lu, G.
2015-08-01
Building data are one of the important data types in a topographic database. Building change detection after a period of time is necessary for many applications, such as identification of informal settlements. Based on the detected changes, the database has to be updated to ensure its usefulness. This paper proposes an improved building detection technique, which is a prerequisite for many building change detection techniques. The improved technique examines the gap between neighbouring buildings in the building mask in order to avoid under segmentation errors. Then, a new building change detection technique from LIDAR point cloud data is proposed. Buildings which are totally new or demolished are directly added to the change detection output. However, for demolished or extended building parts, a connected component analysis algorithm is applied and for each connected component its area, width and height are estimated in order to ascertain if it can be considered as a demolished or new building part. Finally, a graphical user interface (GUI) has been developed to update detected changes to the existing building map. Experimental results show that the improved building detection technique can offer not only higher performance in terms of completeness and correctness, but also a lower number of undersegmentation errors as compared to its original counterpart. The proposed change detection technique produces no omission errors and thus it can be exploited for enhanced automated building information updating within a topographic database. Using the developed GUI, the user can quickly examine each suggested change and indicate his/her decision with a minimum number of mouse clicks.
NASA Astrophysics Data System (ADS)
James, P.
2011-12-01
With a growing need for housing in the U.K., the government has proposed increased development of brownfield sites. However, old mine workings and natural cavities represent a potential hazard before, during and after construction on such sites, and add further complication to subsurface parameters. Cavities are hence a limitation to certain redevelopment and their detection is an ever important consideration. The current standard technique for cavity detection is a borehole grid, which is intrusive, non-continuous, slow and expensive. A new robust investigation standard in the detection of cavities is sought and geophysical techniques offer an attractive alternative. Geophysical techniques have previously been utilised successfully in the detection of cavities in various geologies, but still has an uncertain reputation in the engineering industry. Engineers are unsure of the techniques and are inclined to rely on well known techniques than utilise new technologies. Bad experiences with geophysics are commonly due to the indiscriminate choice of particular techniques. It is imperative that a geophysical survey is designed with the specific site and target in mind at all times, and the ability and judgement to rule out some, or all, techniques. To this author's knowledge no comparative software exists to aid technique choice. Also, previous modelling software limit the shapes of bodies and hence typical cavity shapes are not represented. Here, we introduce 3D modelling software (Matlab) which computes and compares the response to various cavity targets from a range of techniques (gravity, gravity gradient, magnetic, magnetic gradient and GPR). Typical near surface cavity shapes are modelled including shafts, bellpits, various lining and capping materials, and migrating voids. The probability of cavity detection is assessed in typical subsurface and noise conditions across a range of survey parameters. Techniques can be compared and the limits of detection distance assessed. The density of survey points required to achieve a required probability of detection can be calculated. The software aids discriminate choice of technique, improves survey design, and increases the likelihood of survey success; all factors sought in the engineering industry. As a simple example, the response from magnetometry, gravimetry, and gravity gradient techniques above an example 3m deep, 1m cube air cavity in limestone across a 15m grid was calculated. The maximum responses above the cavity are small (amplitudes of 0.018nT, 0.0013mGal, 8.3eotvos respectively), but at typical site noise levels the detection reliability is over 50% for the gradient gravity method on a single survey line. Increasing the number of survey points across the site increases the reliability of detection of the anomaly by the addition of probabilities. We can calculate the probability of detection at different profile spacings to assess the best possible survey design. At 1m spacing the overall probability of by the gradient gravity method is over 90%, and over 60% for magnetometry (at 3m spacing the probability drops to 32%). The use of modelling in near surface surveys is a useful tool to assess the feasibility of a range of techniques to detect subtle signals. Future work will integrate this work with borehole measured parameters.
Experiments on Adaptive Techniques for Host-Based Intrusion Detection
DOE Office of Scientific and Technical Information (OSTI.GOV)
DRAELOS, TIMOTHY J.; COLLINS, MICHAEL J.; DUGGAN, DAVID P.
2001-09-01
This research explores four experiments of adaptive host-based intrusion detection (ID) techniques in an attempt to develop systems that can detect novel exploits. The technique considered to have the most potential is adaptive critic designs (ACDs) because of their utilization of reinforcement learning, which allows learning exploits that are difficult to pinpoint in sensor data. Preliminary results of ID using an ACD, an Elman recurrent neural network, and a statistical anomaly detection technique demonstrate an ability to learn to distinguish between clean and exploit data. We used the Solaris Basic Security Module (BSM) as a data source and performed considerablemore » preprocessing on the raw data. A detection approach called generalized signature-based ID is recommended as a middle ground between signature-based ID, which has an inability to detect novel exploits, and anomaly detection, which detects too many events including events that are not exploits. The primary results of the ID experiments demonstrate the use of custom data for generalized signature-based intrusion detection and the ability of neural network-based systems to learn in this application environment.« less
Detecting position using ARKit
NASA Astrophysics Data System (ADS)
Dilek, Ufuk; Erol, Mustafa
2018-03-01
Developed by using ARKit, a novel app which can be used to detect position in physics experiments was introduced. The ARKit relies on a new technique. The result of the experiment presented in this study was satisfactory, suggesting that the new technique can be employed in position detection experiments/demonstrations that are conducted using mobile technology. This technique has several promising advantages over video analysis.
NASA Astrophysics Data System (ADS)
Zhou, Xiang
Using an innovative portable holographic inspection and testing system (PHITS) developed at the Australian Defence Force Academy, fatigue cracks in riveted lap joints can be detected by visually inspecting the abnormal fringe changes recorded on holographic interferograms. In this thesis, for automatic crack detection, some modern digital image processing techniques are investigated and applied to holographic interferogram evaluation. Fringe analysis algorithms are developed for identification of the crack-induced fringe changes. Theoretical analysis of PHITS and riveted lap joints and two typical experiments demonstrate that the fatigue cracks in lightly-clamped joints induce two characteristic fringe changes: local fringe discontinuities at the cracking sites; and the global crescent fringe distribution near to the edge of the rivet hole. Both of the fringe features are used for crack detection in this thesis. As a basis of the fringe feature extraction, an algorithm for local fringe orientation calculation is proposed. For high orientation accuracy and computational efficiency, Gaussian gradient filtering and neighboring direction averaging are used to minimize the effects of image background variations and random noise. The neighboring direction averaging is also used to approximate the fringe directions in centerlines of bright and dark fringes. Experimental results indicate that for high orientation accuracy the scales of the Gaussian filter and neighboring direction averaging should be chosen according to the local fringe spacings. The orientation histogram technique is applied to detect the local fringe discontinuity due to the fatigue cracks. The Fourier descriptor technique is used to characterize the global fringe distribution change from a circular to a crescent distribution with the fatigue crack growth. Experiments and computer simulations are conducted to analyze the detectability and reliability of crack detection using the two techniques. Results demonstrate that the Fourier descriptor technique is more promising in the detection of the short cracks near the edge of the rivet head. However, it is not as reliable as the fringe orientation technique for detection of the long through cracks. For reliability, both techniques should be used in practical crack detection. Neither the Fourier descriptor technique nor the orientation histogram technique have been previously applied to holographic interferometry. While this work related primarily to interferograms of cracked rivets, the techniques would be readily applied to other areas of fringe pattern analysis.
Eddy-Current Detection Of Cracks In Reinforced Carbon/Carbon
NASA Technical Reports Server (NTRS)
Christensen, Scott V.; Koshti, Ajay M.
1995-01-01
Investigations of failures of components made of reinforced carbon/carbon show eddy-current flaw-detection techniques applicable to these components. Investigation focused on space shuttle parts, but applicable to other parts made of carbon/carbon materials. Techniques reveal cracks, too small to be detected visually, in carbon/carbon matrix substrates and in silicon carbide coates on substrates. Also reveals delaminations in carbon/carbon matrices. Used to characterize extents and locations of discontinuities in substrates in situations in which ultrasonic techniques and destructive techniques not practical.
Signal analysis techniques for incipient failure detection in turbomachinery
NASA Technical Reports Server (NTRS)
Coffin, T.
1985-01-01
Signal analysis techniques for the detection and classification of incipient mechanical failures in turbomachinery were developed, implemented and evaluated. Signal analysis techniques available to describe dynamic measurement characteristics are reviewed. Time domain and spectral methods are described, and statistical classification in terms of moments is discussed. Several of these waveform analysis techniques were implemented on a computer and applied to dynamic signals. A laboratory evaluation of the methods with respect to signal detection capability is described. Plans for further technique evaluation and data base development to characterize turbopump incipient failure modes from Space Shuttle main engine (SSME) hot firing measurements are outlined.
Remote Leak Detection: Indirect Thermal Technique
NASA Technical Reports Server (NTRS)
Clements, Sandra
2002-01-01
Remote sensing technologies are being considered for efficient, low cost gas leak detection. Eleven specific techniques have been identified for further study and evaluation of several of these is underway. The Indirect Thermal Technique is one of the techniques that is being explored. For this technique, an infrared camera is used to detect the temperature change of a pipe or fitting at the site of a gas leak. This temperature change is caused by the change in temperature of the gas expanding from the leak site. During the 10-week NFFP program, the theory behind the technique was further developed, experiments were performed to determine the conditions for which the technique might be viable, and a proof-of-concept system was developed and tested in the laboratory.
NASA Astrophysics Data System (ADS)
Marukhyan, Seda S.; Gasparyan, Vardan K.
2017-02-01
Quantitative determination of HSA was conducted by competitive immunoassay. Inhibition of aggregation of antibody conjugated quantum dots (QD) with albumin conjugated silver nanoparticles (AgNPs) in the presence of HSA was conducted. If antibody-loaded CdSe QDs aggregate with HSA-coated silver nanoparticles the distance between the two kinds of nanoparticles will be reduced enough to cause fluorescence resonance energy transfer (FRET). In this case the yellow fluorescence of the Ab-QDs is quenched. However if HSA (antigen) is added to the Ab-QDs their surface will be blocked and they cannot aggregate any longer with the HSA-AgNPs. Hence, fluorescence will not be quenched. The drop of the intensity of fluorescence (peaking at 570 nm) is inversely correlated with the concentration of HSA in the sample. The method allows to determine HSA in the 30-600 ng·mL-1 concentration range.
The Analysis of Riboflavin in Urine Using Fluorescence
NASA Astrophysics Data System (ADS)
Henderleiter, Julie A.; Hyslop, Richard M.
1996-06-01
To become functional as scientists, chemistry students must integrate concepts learned in their classes and apply them to novel, "real life" situations. The laboratory provides an important place for the students to practice integrating concepts. This laboratory experiment, designed for undergraduate biochemistry students, requires each student to determine the amount of riboflavin excreted by his/her body following oral administration of riboflavin contained in a multi-vitamin tablet. The experimental procedure describes a protocol for the analysis of riboflavin concentration in urine using a fluorometric assay. The students must draw upon their knowledge of solution preparation, construction of a standard curve, and back-calculation procedures to determine the concentration of riboflavin in their urine. Students need to combine knowledge from general and analytical chemistry with that learned in biochemistry to complete this analysis, thus providing an opportunity to integrate knowledge while answering a novel question.
Laser fluorescence spectrometers for medical diagnosis
NASA Astrophysics Data System (ADS)
Kwasny, Miroslaw; Mierczyk, Zygmunt
2000-11-01
The paper presents fibre fluorescence analysers for in vivo examined biological tissues. The systems devoted to clinical investigations are equipped with laser excitation sources; He-Cd (442 nm), Nd:YAG (II and III harmonic: 532 and 355 nm, respectively) and He-Ne (632.8 nm). They allow non-invasive determination of endogenous fluorophones level in any organs as well as monitoring of external sensitisers level when photodynamic method of diagnosis and treatment of tumors is used. Selection of various wavelengths within the range of porphyrines, excitation depends on different light penetration in various tissues. For the tumors localised under mucous membrane, UV, violet, and blue radiation was used for excitation and for deeply localised tumors, a radiation of longer wavelengths (green and red) was used. The carried out clinical examinations showed usefulness of fluorometric systems for diagnostics of skin diseases, gynaecological spheres, and pneumopathies. These analysers can be also applied for environmental protection, food control, and industrial processes monitoring.
Method for Differentiation between Fresh and Frozen-thawed Fish
NASA Astrophysics Data System (ADS)
Kitamikado, Manabu; Yoshioka, Keiko
In Japan fresh fish has a much higher market price than that for frozen-thawed fish. However, a large number of frozen-thawed fish are sold without being differentiated from fresh fish. We discuss here the differentiation methods described in literatures and our works in the search for such a method. We used the opacity of crystalline lens and the destruction of red blood cells as the index for the differentiation, in addition to the activity of neutral β-N-acetylglucosaminidase in blood. Thus, a fluorometric method and a rapid paper test method were developed based on measurement of the activity of this enzyme. This enzyme, found in fish red blood cells, was inactive in intact cells but was activated when cells were disrupted by freezing, and thawing. Both methods were applicable for testing most commom edible fish prior to filleting and required about 20 min using a UV-lamp.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Delmas, R.; Baudet, J.; Servant, J.
Atmospheric H/sub 2/S was measured by a fluorometric method (sensitivity 10 ng). In France, for aerated soils the emissions were between 0.8 and 27 ..mu..g m/sup -2/ h/sup -1/ H/sub 2/S (average 5 ..mu..g m/sup -2/ h/sup -1/). The soil temperature is an important factor governing this emission. The H/sub 2/S concentrations in the air ranged from 0.017 to 0.17 ..mu..g m/sup -3/ (average 0.080 ..mu..g m/sup -3/). In the Ivory Coast the H/sub 2/S emissions were estimated between 30 and 300 ..mu..g m/sup -2/ h/sup -1/. The measured concentrations of H/sub 2/S in the air at ground level rangedmore » from 0.10 to 8.7 ..mu..g m/sup -3/. The relative importance of the measured emissions for anoxic soils of the humid equatorial forests in the global S cycle is discussed.« less
Dye-dispersion study at proposed pumped-storage project on Hudson River at Cornwall, New York
Dunn, Bernard; Gravlee, George C.
1978-01-01
Data were collected during a dye-dispersion study on a 6-mile, tide-affected reach of the Hudson River near the proposed Cornwall Pumped Storage Project on September 21-22, 1977. The results indicated that complete mixing did not occur during the first tidal cycle but was complete after two or more cycles. The fluorometric dye-tracing procedure was used to determine the dispersion characteristics of the water mass. Rhodamine WT dye, 20-percent solution, was continuously injected on the west side of the river throughout an ebb tide, and its movement was monitored during a 30-hour period. Samples were collected both individually and continuously. Automatic dye samplers were used at selected cross sections near each bank. Bathymetric measurements were made at eight cross sections between Newburgh and West Point to determine the depths. (Woodard-USGS)
Development of Carbocyanine Dyes for PRMT Inhibition and Imaging
Sinha, Sarmistha Halder; Owens, Eric A.; Feng, You; Yang, Yutao; Xie, Yan; Tu, Yaping; Henary, Maged; Zheng, Yujun George
2014-01-01
Summary Protein arginine methylation regulates multiple biological processes. Deregulation of protein arginine methyltransferase (PRMT) activities has been observed in many disease phenotypes. Small molecule probes that target PRMTs with strong affinity and selectivity can be used as valuable tools to dissect biological mechanisms of arginine methylation and establish the role of PRMT proteins in a disease process. In this work, we report synthesis and evaluation of a class of carbocyanine compounds containing indolium, benz[e]indolium or benz[c,d]indolium heterocyclic moieties that bind to the predominant arginine methyltransferase PRMT1 and inhibit its methyltransferase activity at low micromolar potencies. In particular, the developed molecules have long wavelength colorimetric and fluorometric photoactivities, which can be used for optical and near-infrared fluorescence imaging in cells or biological tissues. Together, these new chemical probes have potential application in PRMT studies both as enzyme inhibitors and as fluorescent dyes for microscope imaging. PMID:22749641
Rapid and Easy Protocol for Quantification of Next-Generation Sequencing Libraries.
Hawkins, Steve F C; Guest, Paul C
2018-01-01
The emergence of next-generation sequencing (NGS) over the last 10 years has increased the efficiency of DNA sequencing in terms of speed, ease, and price. However, the exact quantification of a NGS library is crucial in order to obtain good data on sequencing platforms developed by the current market leader Illumina. Different approaches for DNA quantification are available currently and the most commonly used are based on analysis of the physical properties of the DNA through spectrophotometric or fluorometric methods. Although these methods are technically simple, they do not allow exact quantification as can be achieved using a real-time quantitative PCR (qPCR) approach. A qPCR protocol for DNA quantification with applications in NGS library preparation studies is presented here. This can be applied in various fields of study such as medical disorders resulting from nutritional programming disturbances.
Lu, Chi-Yu; Wu, Hsin-Lung; Chen, Su-Hwei; Kou, Hwang-Shang; Wu, Shou-Mei
2002-01-02
A highly sensitive high-performance liquid chromatography (HPLC) method is described for the simultaneous determination of some important saturated and unsaturated fatty acids in milk, including lauric (dodecanoic), myristic (tetradecanoic), palmitic (hexadecanoic), stearic (octadecanoic), palmitoleic (hexadecenoic), oleic (octadecenoic), and linoleic acids (octadecadienoic acids). The fatty acids were fluorogenically derivatized with 2-(2-naphthoxy)ethyl 2-(piperidino)ethanesulfonate (NOEPES) as their naphthoxyethyl derivatives. The resulting derivatives were separated by isocratic HPLC and monitored with a fluorometric detector (lambdaex = 235 nm, lambdaem = 350 nm). The fatty acids in milk were extracted with toluene, and the extract with the fatty acids was directly derivatized with NOEPES without solvent replacement. Determination of long-chain free fatty acids in milk is feasible by a standard addition method. A small amount of milk product, 10 microL, is sufficient for the analysis.
Aburto, Jorge; Correa-Basurto, Jose; Torres, Eduardo
2008-12-01
We have identified an atypical kinetic behavior for the oxidative halogenation of several polycyclic aromatic hydrocarbons (PAHs) by chloroperoxidase (CPO) from Caldariomyces fumago. This behavior resembles the capacity of some members of the P450 family to simultaneously recognize several substrate molecules at their active sites. Indeed, fluorometric studies showed that PAHs exist in solution as monomers and pi-pi dimers that interact to different extents with CPO. The dissociation constants of dimerization were evaluated for every single PAH by spectrofluorometry. Furthermore, docking studies also suggest that CPO might recognize either one or two substrate molecules in its active site. The atypical sigmoidal kinetic behavior of CPO in the oxidative halogenation of PAHs is explained in terms of different kinetic models for non-heteroatomic PAHs (naphthalene, anthracene and pyrene). The results suggest that the actual substrate for CPO in this study was the pi-pi dimer for all evaluated PAHs.
Detection technique of targets for missile defense system
NASA Astrophysics Data System (ADS)
Guo, Hua-ling; Deng, Jia-hao; Cai, Ke-rong
2009-11-01
Ballistic missile defense system (BMDS) is a weapon system for intercepting enemy ballistic missiles. It includes ballistic-missile warning system, target discrimination system, anti-ballistic-missile guidance systems, and command-control communication system. Infrared imaging detection and laser imaging detection are widely used in BMDS for surveillance, target detection, target tracking, and target discrimination. Based on a comprehensive review of the application of target-detection techniques in the missile defense system, including infrared focal plane arrays (IRFPA), ground-based radar detection technology, 3-dimensional imaging laser radar with a photon counting avalanche photodiode (APD) arrays and microchip laser, this paper focuses on the infrared and laser imaging detection techniques in missile defense system, as well as the trends for their future development.
Liu, Yang; Gu, Ming; Alocilja, Evangelyn C; Chakrabartty, Shantanu
2010-11-15
An ultra-reliable technique for detecting trace quantities of biomolecules is reported. The technique called "co-detection" exploits the non-linear redundancy amongst synthetically patterned biomolecular logic circuits for deciphering the presence or absence of target biomolecules in a sample. In this paper, we verify the "co-detection" principle on gold-nanoparticle-based conductimetric soft-logic circuits which use a silver-enhancement technique for signal amplification. Using co-detection, we have been able to demonstrate a great improvement in the reliability of detecting mouse IgG at concentration levels that are 10(5) lower than the concentration of rabbit IgG which serves as background interference. Copyright © 2010 Elsevier B.V. All rights reserved.
Cano, I; Alonso, M C; Garcia-Rosado, E; Saint-Jean, S Rodriguez; Castro, D; Borrego, Juan J
2006-03-10
An immunoblot technique for the detection of lymphocystis disease virus (LCDV) in naturally infected gilt-head seabream (Sparus aurata, L.) has been developed. A specific antiserum against a 60 kDa viral protein has been proven to be an appropriate tool for LCDV diagnosis either from inoculated cell cultures or from fish tissues using the immunoblot assay. The sensitivity of this technique varied between 10(-1) and 10(2) TCID50. LCDV has also been detected in fish tissues from both, diseased and asymptomatic gilt-head seabream. For the asymptomatic fish detection, a viral amplification step in cell culture and a subsequent viral concentration using polyethylene glycol (PEG) (600 wt) are required. On the contrary, immunoblot allowed the detection of LCDV antigens directly from tissue homogenates of diseased fish. The method described in this study shows higher sensitivity than classical detection techniques based on cell culture inoculation.
[Application of THz technology to nondestructive detection of agricultural product quality].
Jiang, Yu-ying; Ge, Hong-yi; Lian, Fei-yu; Zhang, Yuan; Xia, Shan-hong
2014-08-01
With recent development of THz sources and detector, applications of THz radiation to nondestructive testing and quality control have expanded in many fields, such as agriculture, safety inspection and quality control, medicine, biochemistry, communication etc. Compared with other detection technique, being a new kind of technique, THz radiation has low energy, good perspectivity, and high signal-to-noise ratio, and thus can obtain physical, chemical and biological information. This paper first introduces the basic concept of THz radiation and the major properties, then gives an extensive review of recent research progress in detection of the quality of agricultural products via THz technique, analyzes the existing shortcomings of THz detection and discusses the outlook of potential application, finally proposes the new application of THz technique to detection of quality of stored grain.
Ishiwata, Sayuri; Hattori, Kotaro; Sasayama, Daimei; Teraishi, Toshiya; Miyakawa, Tomoko; Yokota, Yuuki; Matsumura, Ryo; Nishikawa, Toru; Kunugi, Hiroshi
2018-01-15
D-serine is an endogenous co-agonist of N-methyl-D-aspartate receptor (NMDAR) and plays an important role in glutamate neurotransmission. Several studies suggested the possible involvement of D-serine related in the pathophysiology of psychiatric disorders including major depression disorders (MDD). We tried to examine whether cerebrospinal fluid (CSF) or plasma D-serine concentrations are altered in MDD and whether D-serine concentrations correlated with disease severity. 26 MDD patients and 27 healthy controls matched for age, sex and ethnicity were enrolled. We measured amino acids in these samples using by high-performance liquid chromatography with fluorometric detection. D-serine and L-serine, precursor of D-serine, levels in CSF or plasma were not significantly different in patients of MDD compared to controls. Furthermore, a significant correlation between D-serine levels in CSF and Hamilton Depression Rating Scale (HAMD)-17 score was observed (r = -0.65, p = 0.006). Furthermore, we found a positive correlation between CSF D-serine and HVA concentrations in MDD patients (r = 0.54, p = 0.007). CSF D-serine concentrations were correlated with those of plasma in MDD (r = 0.61, p = 0.01) but not in controls. In CSF, we also confirmed a significant correlation between D-serine and L-serine levels in MDD (r = 0.72, p < 0.0001) and controls (r = 0.70, p < 0.0001). The study has some limitations; sample size was relatively small and most patients were medicated. We revealed that CSF D-serine concentrations were correlated with depression severity and HVA concentrations and further investigation were required to reveal the effect of medication and disease heterogeneity. Copyright © 2017 Elsevier B.V. All rights reserved.
Pathogen Phytosensing: Plants to Report Plant Pathogens.
Mazarei, Mitra; Teplova, Irina; Hajimorad, M Reza; Stewart, C Neal
2008-04-14
Real-time systems that provide evidence of pathogen contamination in crops can be an important new line of early defense in agricultural centers. Plants possess defense mechanisms to protect against pathogen attack. Inducible plant defense is controlled by signal transduction pathways, inducible promoters and cis-regulatory elements corresponding to key genes involved in defense, and pathogen-specific responses. Identified inducible promoters and cis-acting elements could be utilized in plant sentinels, or 'phytosensors', by fusing these to reporter genes to produce plants with altered phenotypes in response to the presence of pathogens. Here, we have employed cis-acting elements from promoter regions of pathogen inducible genes as well as those responsive to the plant defense signal molecules salicylic acid, jasmonic acid, and ethylene. Synthetic promoters were constructed by combining various regulatory elements supplemented with the enhancer elements from the Cauliflower mosaic virus (CaMV) 35S promoter to increase basal level of the GUS expression. The inducibility of each synthetic promoter was first assessed in transient expression assays using Arabidopsis thaliana protoplasts and then examined for efficacy in stably transgenic Arabidopsis and tobacco plants. Histochemical and fluorometric GUS expression analyses showed that both transgenic Arabidopsis and tobacco plants responded to elicitor and phytohormone treatments with increased GUS expression when compared to untreated plants. Pathogen-inducible phytosensor studies were initiated by analyzing the sensitivity of the synthetic promoters against virus infection. Transgenic tobacco plants infected with Alfalfa mosaic virus showed an increase in GUS expression when compared to mock-inoculated control plants, whereas Tobacco mosaic virus infection caused no changes in GUS expression. Further research, using these transgenic plants against a range of different pathogens with the regulation of detectable reporter gene could provide biological evidence to define the functional differences between pathogens, and provide new technology and applications for transgenic plants as phytosensors.
Fenugreek increases insulin-stimulated creatine content in L6C11 muscle myotubes.
Tomcik, Kristyen A; Smiles, William J; Camera, Donny M; Hügel, Helmut M; Hawley, John A; Watts, Rani
2017-04-01
Creatine uptake by muscle cells is increased in the presence of insulin. Accordingly, compounds with insulin-like actions may also augment creatine uptake. The aim of this study was to investigate whether Trigonella foenum-graecum (fenugreek), an insulin mimetic, increases total intracellular creatine levels in vitro. Total cellular creatine content was measured fluorometrically in L6C11 muscle myotubes treated for 1, 4, and 24 h with 0.5 mM creatine (CR), CR and 20 μg/mL fenugreek seed extract (CR + FEN), CR and 100 nM insulin (CR + INS), and CR + INS + FEN (n = 6 per treatment group). Alterations in the expression of the sodium- and chloride-dependent creatine transporter, SLC6A8, and key signaling proteins in the PI3-K/Akt pathway were determined. Compared to control (CON), CR + INS + FEN increased total creatine content after 4 h (P < 0.05), whereas all conditions increased SLC6A8 protein expression above CON at this time (P < 0.05). Changes in insulin signaling were demonstrated via increases in Akt Thr308 phosphorylation, with CR + INS > CON and CR at 1 h (P < 0.05) and with CR + INS + FEN > CON, CR, and CR + INS at 4 h (P < 0.05). In contrast, no changes in PKCζ/λ or GLUT4 phosphorylation were detected. Fenugreek, when combined with insulin, modulates creatine content via a mechanism which is independent of the activity of SLC6A8, suggesting that an alternative mechanism is responsible for the regulation and facilitation of insulin-mediated creatine uptake in skeletal muscle cells.
Govaris, A; Roussi, V; Koidis, P A; Botsoglou, N A
2001-05-01
Telemes cheeses were produced using milk that was artificially-contaminated with aflatoxin M1 at the levels of 0.050 and 0.100 microg/l. The cheeses produced in the two cheese-making trials were allowed to ripen for 2 months and stored for an additional 4 months to simulate commercial production of Telemes cheese. Concentrations of aflatoxin M1 in whey, curd, brine, and the produced cheeses were determined at intervals by liquid chromatography and fluorometric detection coupled with immunoaffinity column extraction. Concentrations of aflatoxin M1 in the produced curds were found to be 3.9 and 4.4 times higher than those in milk, whereas concentrations in whey were lower than those in curd and milk. Aflatoxin M1 was present in cheese at higher concentrations at the beginning than at the end of the ripening/storage period, and it declined to concentrations 2.7 and 3.4 times higher than those initially present in milk by the end of the sixth month of storage. Concentrations of aflatoxin M1 in brine started low and increased by the end of the ripening/storage period but only a portion of the amounts of aflatoxin M1 lost from cheese was found in the brine. Results showed that Telemes cheeses produced from milk containing aflatoxin M1 at a concentration close to either the maximum acceptable level of 0.05 microg/l set by the European union (EU) or at double this value, will contain the toxin at a level that is much lower or slightly higher, respectively, than the maximum acceptable level of 0.250 microg of aflatoxin M1/kg cheese set by some countries.
Gwynn, Babette; Lueders, Kira; Sands, Mark S.; Birkenmeier, Edward H.
1998-01-01
The severity of human mucopolysaccharidosis type VII (MPS VII), or Sly syndrome, depends on the relative activity of the enzyme β-glucuronidase. Loss of β-glucuronidase activity can cause hydrops fetalis, with in utero or postnatal death of the patient. In this report, we show that β-glucuronidase activity is not detectable by a standard fluorometric assay in C3H/HeOuJ (C3H) mice homozygous for a new mutation, gusmps2J. These gusmps2J/gusmps2J mice are born and survive much longer than the previously characterized β-glucuronidase-null B6.C-H-2bm1/ByBir-gusmps (gusmps/gusmps) mice. Northern blot analysis of liver from gusmps2J/gusmps2J mice demonstrates a 750-bp reduction in size of β-glucuronidase mRNA. A 5.4-kb insertion in the Gus-sh nucleotide sequence from these mice was localized by Southern blot analysis to intron 8. The ends of the inserted sequences were cloned by inverse PCR and revealed an intracisternal A-particle (IAP) element inserted near the 3′ end of the intron. The sequence of the long terminal repeat (LTR) regions of the IAP most closely matches that of a composite LTR found in transposed IAPs previously identified in the C3H strain. The inserted IAP may contribute to diminished β-glucuronidase activity either by interfering with transcription or by destabilizing the message. The resulting phenotype is much less severe than that previously described in the gusmps/gusmps mouse and provides an opportunity to study MPS VII on a genetic background that clearly modulates disease severity. PMID:9774663
Coelho, Tatiane; Machado, Diana; Couto, Isabel; Maschmann, Raquel; Ramos, Daniela; von Groll, Andrea; Rossetti, Maria L.; Silva, Pedro A.; Viveiros, Miguel
2015-01-01
Drug resistant tuberculosis continues to increase and new approaches for its treatment are necessary. The identification of M. tuberculosis clinical isolates presenting efflux as part of their resistant phenotype has a major impact in tuberculosis treatment. In this work, we used a checkerboard procedure combined with the tetrazolium microplate-based assay (TEMA) to study single combinations between antituberculosis drugs and efflux inhibitors (EIs) against multidrug resistant M. tuberculosis clinical isolates using the fully susceptible strain H37Rv as reference. Efflux activity was studied on a real-time basis by a fluorometric method that uses ethidium bromide as efflux substrate. Quantification of efflux pump genes mRNA transcriptional levels were performed by RT-qPCR. The fractional inhibitory concentrations (FIC) indicated synergistic activity for the interactions between isoniazid, rifampicin, amikacin, ofloxacin, and ethidium bromide plus the EIs verapamil, thioridazine and chlorpromazine. The FICs ranged from 0.25, indicating a four-fold reduction on the MICs, to 0.015, 64-fold reduction. The detection of active efflux by real-time fluorometry showed that all strains presented intrinsic efflux activity that contributes to the overall resistance which can be inhibited in the presence of the EIs. The quantification of the mRNA levels of the most important efflux pump genes on these strains shows that they are intrinsically predisposed to expel toxic compounds as the exposure to subinhibitory concentrations of antibiotics were not necessary to increase the pump mRNA levels when compared with the non-exposed counterpart. The results obtained in this study confirm that the intrinsic efflux activity contributes to the overall resistance in multidrug resistant clinical isolates of M. tuberculosis and that the inhibition of efflux pumps by the EIs can enhance the clinical effect of antibiotics that are their substrates. PMID:25972842
Pharmacological studies of stonefish (Synanceja trachynis) venom.
Hopkins, B J; Hodgson, W C; Sutherland, S K
1994-10-01
The present study was designed to examine some of the pharmacological properties of venom from the stonefish (Synanceja trachynis), with particular reference to the presence in the venom of pain-producing/enhancing substances. Stonefish venom (1-6 micrograms/ml) produced concentration-dependent contractile responses in guinea-pig isolated ileum. No tachyphylaxis, or reduction in responses with time, was observed to venom (3 micrograms/ml) in ileum. The response to venom (3 micrograms/ml) was not significantly affected by the histamine antagonist mepyramine (0.5 microM), or a preceding anaphylactic response. Mecamylamine, 5HT-desensitization or EXP3174 failed to have any significant effect on responses to venom (3 micrograms/ml). Responses to venom (3 micrograms/ml) were significantly inhibited by the cyclooxygenase inhibitor indomethacin (5 microM), the leukotriene D4 receptor antagonist FLP55712 (1 microM), the thromboxane A2 receptor antagonist GR32191B (1 microM), the muscarinic receptor antagonist atropine (10 nM) and the neurokinin-1 receptor antagonist CP96345 (0.1 microM). Venom (6 micrograms/ml) produced contractile responses in the rat isolated vas deferens which were abolished by the alpha 1-adrenoceptor antagonist prazosin (0.3 microM) and significantly potentiated by the neuronal uptake inhibitor DMI (1 microM). However, noradrenergic transmitter depletion with reserpine (5 mg/kg, i.p.) did not significantly inhibit responses to venom (6 micrograms/ml). Histamine fluorometric and phospholipase A2 assays failed to detect significant quantities of either substance in the venom. These results suggest that stonefish venom may cause the release of acetylcholine, substance P, and cyclooxygenase products, or contain components which act at these receptors. The venom also appears to contain a component which is a substrate for neuronal uptake and has a direct action at alpha 1-adrenoceptors.
Real-time Measurements of Amino Acid and Protein Hydroperoxides Using Coumarin Boronic Acid*
Michalski, Radoslaw; Zielonka, Jacek; Gapys, Ewa; Marcinek, Andrzej; Joseph, Joy; Kalyanaraman, Balaraman
2014-01-01
Hydroperoxides of amino acid and amino acid residues (tyrosine, cysteine, tryptophan, and histidine) in proteins are formed during oxidative modification induced by reactive oxygen species. Amino acid hydroperoxides are unstable intermediates that can further propagate oxidative damage in proteins. The existing assays (oxidation of ferrous cation and iodometric assays) cannot be used in real-time measurements. In this study, we show that the profluorescent coumarin boronic acid (CBA) probe reacts with amino acid and protein hydroperoxides to form the corresponding fluorescent product, 7-hydroxycoumarin. 7-Hydroxycoumarin formation was catalase-independent. Based on this observation, we have developed a fluorometric, real-time assay that is adapted to a multiwell plate format. This is the first report showing real-time monitoring of amino acid and protein hydroperoxides using the CBA-based assay. This approach was used to detect protein hydroperoxides in cell lysates obtained from macrophages exposed to visible light and photosensitizer (rose bengal). We also measured the rate constants for the reaction between amino acid hydroperoxides (tyrosyl, tryptophan, and histidine hydroperoxides) and CBA, and these values (7–23 m−1 s−1) were significantly higher than that measured for H2O2 (1.5 m−1 s−1). Using the CBA-based competition kinetics approach, the rate constants for amino acid hydroperoxides with ebselen, a glutathione peroxidase mimic, were also determined, and the values were within the range of 1.1–1.5 × 103 m−1 s−1. Both ebselen and boronates may be used as small molecule scavengers of amino acid and protein hydroperoxides. Here we also show formation of tryptophan hydroperoxide from tryptophan exposed to co-generated fluxes of nitric oxide and superoxide. This observation reveals a new mechanism for amino acid and protein hydroperoxide formation in biological systems. PMID:24928516
Ohsaki, M; Tsutsumi, H; Kumagai, T; Yamanaka, T; Wataya, Y; Furukawa, H; Kojima, H; Saito, A; Yano, S; Chiba, S
1999-02-01
The immune mechanism of gelatin allergy, especially the participation of TH1 and TH2 cells and their cytokine secretion, has not been investigated. We investigated the characteristics of T lymphocytes from patients allergic to gelatin-containing vaccine by secondary in vitro stimulation of circulating mononuclear cells with gelatin. We studied 8 children with a history of immediate-type reactions and 8 with nonimmediate-type reactions after inoculation of gelatin-containing vaccine. The expression of IFN-gamma (TH1 ), IL-2 (TH1 ), IL-4 (TH2 ), and IL-13 (TH2 ) mRNA was examined semiquantitatively by using a reverse transcriptase PCR. IgE antibody to bovine gelatin was measured with the fluorometric ELISA system, and gelatin-specific T-cell responses were detected by an in vitro lymphocyte proliferation assay. Patients with an immediate reaction all had gelatin-specific IgE antibody, whereas others did not. However, all patients exhibited positive T-lymphocyte responses specific to gelatin. Lymphocytes from subjects with nonimmediate-type reactions generally expressed very weak or sometimes no IFN-gamma, IL-2, or IL-13 genes and especially no IL-4 gene. On the other hand, the lymphocytes of subjects with immediate-type reactions significantly expressed not only IL-4 and IL-13 but also IFN-gamma and IL-2 mRNA. Our observations suggest that both gelatin-specific TH2 and TH1 responses are involved in the pathogenesis of the immediate reaction to gelatin. The gelatin-specific IL-4 and/or IL-13 responses consistently observed in patients with an immediate reaction may be associated with the production of gelatin-specific IgE antibody.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Solaimani, Mohiuddin; Iftekhar, Mohammed; Khan, Latifur
Anomaly detection refers to the identi cation of an irregular or unusual pat- tern which deviates from what is standard, normal, or expected. Such deviated patterns typically correspond to samples of interest and are assigned different labels in different domains, such as outliers, anomalies, exceptions, or malware. Detecting anomalies in fast, voluminous streams of data is a formidable chal- lenge. This paper presents a novel, generic, real-time distributed anomaly detection framework for heterogeneous streaming data where anomalies appear as a group. We have developed a distributed statistical approach to build a model and later use it to detect anomaly. Asmore » a case study, we investigate group anomaly de- tection for a VMware-based cloud data center, which maintains a large number of virtual machines (VMs). We have built our framework using Apache Spark to get higher throughput and lower data processing time on streaming data. We have developed a window-based statistical anomaly detection technique to detect anomalies that appear sporadically. We then relaxed this constraint with higher accuracy by implementing a cluster-based technique to detect sporadic and continuous anomalies. We conclude that our cluster-based technique out- performs other statistical techniques with higher accuracy and lower processing time.« less
A Comparative Study of Unsupervised Anomaly Detection Techniques Using Honeypot Data
NASA Astrophysics Data System (ADS)
Song, Jungsuk; Takakura, Hiroki; Okabe, Yasuo; Inoue, Daisuke; Eto, Masashi; Nakao, Koji
Intrusion Detection Systems (IDS) have been received considerable attention among the network security researchers as one of the most promising countermeasures to defend our crucial computer systems or networks against attackers on the Internet. Over the past few years, many machine learning techniques have been applied to IDSs so as to improve their performance and to construct them with low cost and effort. Especially, unsupervised anomaly detection techniques have a significant advantage in their capability to identify unforeseen attacks, i.e., 0-day attacks, and to build intrusion detection models without any labeled (i.e., pre-classified) training data in an automated manner. In this paper, we conduct a set of experiments to evaluate and analyze performance of the major unsupervised anomaly detection techniques using real traffic data which are obtained at our honeypots deployed inside and outside of the campus network of Kyoto University, and using various evaluation criteria, i.e., performance evaluation by similarity measurements and the size of training data, overall performance, detection ability for unknown attacks, and time complexity. Our experimental results give some practical and useful guidelines to IDS researchers and operators, so that they can acquire insight to apply these techniques to the area of intrusion detection, and devise more effective intrusion detection models.
[Aging explosive detection using terahertz time-domain spectroscopy].
Meng, Kun; Li, Ze-ren; Liu, Qiao
2011-05-01
Detecting the aging situation of stock explosive is essentially meaningful to the research on the capability, security and stability of explosive. Existing aging explosive detection techniques, such as scan microscope technique, Fourier transfer infrared spectrum technique, gas chromatogram mass spectrum technique and so on, are either not able to differentiate whether the explosive is aging or not, or not able to image the structure change of the molecule. In the present paper, using the density functional theory (DFT), the absorb spectrum changes after the explosive aging were calculated, from which we can clearly find the difference of spectrum between explosive molecule and aging ones in the terahertz band. The terahertz time-domain spectrum (THz-TDS) system as well as its frequency spectrum resolution and measured range are analyzed. Combined with the existing experimental results and the essential characters of the terahertz wave, the application of THz-TDS technique to the detection of aging explosive was demonstrated from the aspects of feasibility, veracity and practicability. On the base of that, the authors advance the new method of aging explosive detection using the terahertz time-domain spectrum technique.
Microwave Technique for Detecting and Locating Concealed Weapons
DOT National Transportation Integrated Search
1971-12-01
The subject of this report is the evaluation of a microwave technique for detecting and locating weapons concealed under clothing. The principal features of this technique are: persons subjected to search are not exposed to 'objectional' microwave ra...
Flood Detection/Monitoring Using Adjustable Histogram Equalization Technique
Riaz, Muhammad Mohsin; Ghafoor, Abdul
2014-01-01
Flood monitoring technique using adjustable histogram equalization is proposed. The technique overcomes the limitations (overenhancement, artifacts, and unnatural look) of existing technique by adjusting the contrast of images. The proposed technique takes pre- and postimages and applies different processing steps for generating flood map without user interaction. The resultant flood maps can be used for flood monitoring and detection. Simulation results show that the proposed technique provides better output quality compared to the state of the art existing technique. PMID:24558332
Antweiler, Ronald C.; Taylor, Howard E.
2008-01-01
The main classes of statistical treatment of below-detection limit (left-censored) environmental data for the determination of basic statistics that have been used in the literature are substitution methods, maximum likelihood, regression on order statistics (ROS), and nonparametric techniques. These treatments, along with using all instrument-generated data (even those below detection), were evaluated by examining data sets in which the true values of the censored data were known. It was found that for data sets with less than 70% censored data, the best technique overall for determination of summary statistics was the nonparametric Kaplan-Meier technique. ROS and the two substitution methods of assigning one-half the detection limit value to censored data or assigning a random number between zero and the detection limit to censored data were adequate alternatives. The use of these two substitution methods, however, requires a thorough understanding of how the laboratory censored the data. The technique of employing all instrument-generated data - including numbers below the detection limit - was found to be less adequate than the above techniques. At high degrees of censoring (greater than 70% censored data), no technique provided good estimates of summary statistics. Maximum likelihood techniques were found to be far inferior to all other treatments except substituting zero or the detection limit value to censored data.
Performance limitations of label-free sensors in molecular diagnosis using complex samples
NASA Astrophysics Data System (ADS)
Varma, Manoj
2016-03-01
Label-free biosensors promised a paradigm involving direct detection of biomarkers from complex samples such as serum without requiring multistep sample processing typical of labelled methods such as ELISA or immunofluorescence assays. Label-free sensors have witnessed decades of development with a veritable zoo of techniques available today exploiting a multitude of physical effects. It is appropriate now to critically assess whether label-free technologies have succeeded in delivering their promise with respect to diagnostic applications, particularly, ambitious goals such as early cancer detection using serum biomarkers, which require low limits of detection (LoD). Comparison of nearly 120 limits of detection (LoD) values reported by labelled and label-free sensing approaches over a wide range of detection techniques and target molecules in serum revealed that labeled techniques achieve 2-3 orders of magnitude better LoDs. Data from experiments where labelled and label-free assays were performed simultaneously using the same assay parameters also confirm that the LoD achieved by labelled techniques is 2 to 3 orders of magnitude better than that by label-free techniques. Furthermore, label-free techniques required significant signal amplification, for e.g. using nanoparticle conjugated secondary antibodies, to achieve LoDs comparable to labelled methods substantially deviating from the original "direct detection" paradigm. This finding has important implications on the practical limits of applying label-free detection methods for molecular diagnosis.
Characterization of emission microscopy and liquid crystal thermography in IC fault localization
NASA Astrophysics Data System (ADS)
Lau, C. K.; Sim, K. S.
2013-05-01
This paper characterizes two fault localization techniques - Emission Microscopy (EMMI) and Liquid Crystal Thermography (LCT) by using integrated circuit (IC) leakage failures. The majority of today's semiconductor failures do not reveal a clear visual defect on the die surface and therefore require fault localization tools to identify the fault location. Among the various fault localization tools, liquid crystal thermography and frontside emission microscopy are commonly used in most semiconductor failure analysis laboratories. Many people misunderstand that both techniques are the same and both are detecting hot spot in chip failing with short or leakage. As a result, analysts tend to use only LCT since this technique involves very simple test setup compared to EMMI. The omission of EMMI as the alternative technique in fault localization always leads to incomplete analysis when LCT fails to localize any hot spot on a failing chip. Therefore, this research was established to characterize and compare both the techniques in terms of their sensitivity in detecting the fault location in common semiconductor failures. A new method was also proposed as an alternative technique i.e. the backside LCT technique. The research observed that both techniques have successfully detected the defect locations resulted from the leakage failures. LCT wass observed more sensitive than EMMI in the frontside analysis approach. On the other hand, EMMI performed better in the backside analysis approach. LCT was more sensitive in localizing ESD defect location and EMMI was more sensitive in detecting non ESD defect location. Backside LCT was proven to work as effectively as the frontside LCT and was ready to serve as an alternative technique to the backside EMMI. The research confirmed that LCT detects heat generation and EMMI detects photon emission (recombination radiation). The analysis results also suggested that both techniques complementing each other in the IC fault localization. It is necessary for a failure analyst to use both techniques when one of the techniques produces no result.
Kosiak, Elzbieta Barbara; Holst-Jensen, Arne; Rundberget, Thomas; Gonzalez Jaen, Maria Teresa; Torp, Mona
2005-03-15
The morphological variation, secondary metabolite profiles and restriction fragment length polymorphisms (RFLPs) of PCR amplified intergenic spacer (IGS) ribosomal DNA (rDNA) were studied in 27 isolates of Fusarium equiseti, 25 isolated from Norwegian cereals and 2 from soil obtained from the IBT culture collection (BioCentrum, Technical University of Denmark). All 27 isolates were tested for production of fusarochromanone (FUSCHR), zearalenone (ZEA) and the trichothecenes: 15-monoacetoxy-scirpentriol (MAS), diacetoxy-scirpenol (DAS), T-2 and HT-2 toxins, T2-triol, neosolaniol (NEO), deoxynivalenol (DON), nivalenol (NIV) and 4-acetylnivalenol (Fus-X). The trichothecenes were analysed by GC-MS in a selected ion monitoring mode, while FUSCHR was determined by ion pair HPLC with fluorometric detection and production of ZEA by TLC. For amplification of IGS rDNA primers CNL12 and CNS1 were applied. IGS rDNA was digested with the four restriction enzymes: AvaII, CfoI, EcoRI and Sau3A. In addition, we sequenced the IGS rDNA region of three of the Norwegian isolates. There were two morphological types among the Norwegian strains of F. equiseti, type I with short apical cells (dominating) and type II with long apical cells, with four haplotypes identified based on the RFLP data. Variation in secondary metabolite profiles within and between the morphological groups was observed and the levels of produced toxins were: FUSCHR 3000-42,500 and 25-30 ng/g, NIV 20-2500 and 120-700 ng/g, FUS-X 20-15,000 and 0 ng/g, DAS 30-7500 and 0-600 ng/g, and MAS 10-600 and 0-500 ng/g, for strains with short and long apical cells, respectively. NEO was detected in 16/27 strains tested (all morphotype I). All but four strains of type I (these four lacked a restriction site for EcoRI) had identical RFLP profiles. The isolates of type II had two haplotypes. The IGS sequence similarity data indicated differences between these morphotypes corresponding to two separate lineages apparently at the species level.
Mapping Diffuse Seismicity Using Empirical Matched Field Processing Techniques
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, J; Templeton, D C; Harris, D B
The objective of this project is to detect and locate more microearthquakes using the empirical matched field processing (MFP) method than can be detected using only conventional earthquake detection techniques. We propose that empirical MFP can complement existing catalogs and techniques. We test our method on continuous seismic data collected at the Salton Sea Geothermal Field during November 2009 and January 2010. In the Southern California Earthquake Data Center (SCEDC) earthquake catalog, 619 events were identified in our study area during this time frame and our MFP technique identified 1094 events. Therefore, we believe that the empirical MFP method combinedmore » with conventional methods significantly improves the network detection ability in an efficient matter.« less
Outside-out "sniffer-patch" clamp technique for in situ measures of neurotransmitter release.
Muller-Chrétien, Emilie
2014-01-01
The mechanism underlying neurotransmitter release is a critical research domain for the understanding of neuronal network function; however, few techniques are available for the direct detection and measurement of neurotransmitter release. To date, the sniffer-patch clamp technique is mainly used to investigate these mechanisms from individual cultured cells. In this study, we propose to adapt the sniffer-patch clamp technique to in situ detection of neurosecretion. Using outside-out patches from donor cells as specific biosensors plunged in acute cerebral slices, this technique allows for proper detection and quantification of neurotransmitter release at the level of the neuronal network.
Aspartate Aminotransferase (AST/GOT) and Alanine Aminotransferase (ALT/GPT) Detection Techniques
Huang, Xing-Jiu; Choi, Yang-Kyu; Im, Hyung-Soon; Yarimaga, Oktay; Yoon, Euisik; Kim, Hak-Sung
2006-01-01
The levels of aspartate aminotransferase (AST/GOT) and alanine aminotransferase (ALT/GPT) in serum can help people diagnose body tissues especially the heart and the liver are injured or not. This article provides a comprehensive review of research activities that concentrate on AST/GOT and ALT/GPT detection techniques due to their clinical importance. The detection techniques include colorimetric, spectrophotometric, chemiluminescence, chromatography, fluorescence and UV absorbance, radiochemical, and electrochemical techniques. We devote the most attention on experimental principle. In some methods a few representative devices and important conclusions are presented.
Terahertz wave electro-optic measurements with optical spectral filtering
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ilyakov, I. E., E-mail: igor-ilyakov@mail.ru; Shishkin, B. V.; Kitaeva, G. Kh.
We propose electro-optic detection techniques based on variations of the laser pulse spectrum induced during pulse co-propagation with terahertz wave radiation in a nonlinear crystal. Quantitative comparison with two other detection methods is made. Substantial improvement of the sensitivity compared to the standard electro-optic detection technique (at high frequencies) and to the previously shown technique based on laser pulse energy changes is demonstrated in experiment.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee, D.O.; Wayland, J.R.
1991-03-01
The objective of this work was to investigate whether a subsurface plume may be detected and followed using crosshole and surface-to-borehole electromagnetic geophysical techniques. both of these techniques were experimentally demonstrated to be feasible. The presence of the injected plume was easily detected with these methods but additional work must be done to refine the techniques. 5 refs., 15 figs., 1 tab.
Plasmonic SERS nanochips and nanoprobes for medical diagnostics and bio-energy applications
NASA Astrophysics Data System (ADS)
Ngo, Hoan T.; Wang, Hsin-Neng; Crawford, Bridget M.; Fales, Andrew M.; Vo-Dinh, Tuan
2017-02-01
The development of rapid, easy-to-use, cost-effective, high accuracy, and high sensitive DNA detection methods for molecular diagnostics has been receiving increasing interest. Over the last five years, our laboratory has developed several chip-based DNA detection techniques including the molecular sentinel-on-chip (MSC), the multiplex MSC, and the inverse molecular sentinel-on-chip (iMS-on-Chip). In these techniques, plasmonic surface-enhanced Raman scattering (SERS) Nanowave chips were functionalized with DNA probes for single-step DNA detection. Sensing mechanisms were based on hybridization of target sequences and DNA probes, resulting in a distance change between SERS reporters and the Nanowave chip's gold surface. This distance change resulted in change in SERS intensity, thus indicating the presence and capture of the target sequences. Our techniques were single-step DNA detection techniques. Target sequences were detected by simple delivery of sample solutions onto DNA probe-functionalized Nanowave chips and SERS signals were measured after 1h - 2h incubation. Target sequence labeling or washing to remove unreacted components was not required, making the techniques simple, easy-to-use, and cost effective. The usefulness of the techniques for medical diagnostics was illustrated by the detection of genetic biomarkers for respiratory viral infection and of dengue virus 4 DNA.
Fraser, L; Lecewicz, M; Strzezek, J
2002-01-01
A study was conducted to assess viability and mitochondrial status of boar spermatozoa stored at 5 degrees C and 16 degrees C. Gel-free ejaculates, collected from 3 mature boars, were extended in a standard diluent (K3) supplemented with a low-density lipoprotein fraction (LDF) isolated from egg yolk, and stored for 96 h at 5 degrees C and 16 degrees C. Motility analysis was conducted after semen dilution (D0) and on D1-D4 of storage. A double staining method, rhodamine 123 (R123) and propidium iodide (PI), was used to assess sperm viability and mitochondrial status. Sperm viability was also assessed using Hoechst 33,258 (H33258) stain. In fresh semen samples, the percentage of motility was significantly correlated with the percentage of viable spermatozoa with functional mitochondria (R123-PI), viable spermatozoa determined by H33258 staining and ATP content (r = 0.88, p < or = 0.01; r = 0.69, p < or = 0.05; r = 0.77, p < or = 0.01, respectively). The ATP content was also positively correlated with the percentage of viable spermatozoa with functional mitochondria (r = 0.76, p < or = 0.01). Sperm cells progressively lost motility, viability and mitochondrial capacity when stored in the supportive media at 5 degrees C and 16 degrees C. Motility estimates were lower (p < or = 0.05) than the percentage of viable spermatozoa with functional mitochondria during storage in K3 and LDF-based diluents on D4 and D3-D4, respectively. Deterioration in motility and membrane integrity was less marked in spermatozoa stored in LDF-based diluents. Spermatozoa doubly-stained with R123-PI appeared to possess some functional mitochondria, particularly in LDF-based diluent semen. Estimates of sperm viability, as determined by R123-PI staining, were equivalent (p > or = 0.05) to estimates made using H33258 staining. A decrease in mitochondrial activity, as measured by R123 uptake, was accompanied by lower ATP content in spermatozoa stored in K3 and LDF-based diluents after 48 h and 72 h of storage, respectively. Fluorometric measurements of viability and mitochondrial status of boar spermatozoa during liquid storage seem to provide reliable information about the sperm functional membranes.
Cieniak, Carolina; Liu, Rui; Fottinger, Alexandra; Smiley, Sheila A M; Guerrero-Analco, Jose A; Bennett, Steffany A L; Haddad, Pierre S; Cuerrier, Alain; Saleem, Ammar; Arnason, John T; Foster, Brian C
2013-12-12
Interactions between conventional drug and traditional medicine therapies may potentially affect drug efficacy and increase the potential for adverse reactions. Cree traditional healing is holistic and patients may use medicinal plants simultaneously with the conventional drugs. However, there is limited information that these medicinal plants may interact with drugs and additional mechanistic information is required. In this study, extracts from traditionally used Cree botanicals were assessed for their potential interaction that could alter the disposition of two blood glucose lowering drugs, gliclazide (Diamicron) and repaglinide (Gluconorm) though inhibition of either metabolism or transport across cell membranes. The effect of 17 extracts on metabolism was examined in a human liver microsome assay by HPLC and individual cytochrome P450s 2C9, 2C19, 2C8 and 3A4 in a microplate fluorometric assay. Gliclazide, rhaponticin and its aglycone derivative, rhapontigenin were also examined in the fluorometric assay. The effect on transport was examined with 11 extracts using the intestinal epithelial Caco-2 differentiated cell monolayer model at times up to 180 min. Both blood glucose lowering medications, gliclazide and repaglinide traversed the Caco-2 monolayer in a time-dependent manner that was not affected by the Cree plant extracts. Incubation of the Cree plant extracts inhibited CYP2C9, 2C19, 2C8 and 3A4-mediated metabolism, and the formation of four repaglinide metabolites: M4, m/z 451-A, m/z 451-B and the glucuronide of repaglinide in the human liver microsome assay. Gliclazide caused no significant inhibition. Likewise, rhaponticin had little effect on the enzymes causing changes of less than 10% with an exception of 17% inhibition of CYP2C19. By contrast, the aglycone rhapontigenin showed the greatest effects on all CYP-mediated metabolism. Its inhibition ranged from a mean of 58% CYP3A4 inhibition to 89% inhibition of CYP2C9. While rhaponticin and the aglycone did not show significant effects on repaglinide metabolism, they demonstrated inhibition of gliclazide metabolism. The aglycone significantly affected levels of gliclazide and its metabolites. These studies demonstrate that the Cree plant extracts examined have the potential in vitro to cause drug interactions through effects on key metabolic enzymes. © 2013 Elsevier Ireland Ltd. All rights reserved.
Ground penetrating radar (GPR) detects fine roots of agricultural crops in the field
Xiuwei Liu; Xuejun Dong; Qingwu Xue; Daniel I. Leskovar; John Jifon; John R. Butnor; Thomas Marek
2018-01-01
Aim Ground penetrating radar (GPR) as a non-invasive technique is widely used in coarse root detection. However, the applicability of the technique to detect fine roots of agricultural crops is unknown. The objective of this study was to assess the feasibility of utilizing GPR to detect fine roots in the field.
NASA Technical Reports Server (NTRS)
Shives, T. R. (Editor); Willard, W. A. (Editor)
1981-01-01
The contribution of failure detection, diagnosis and prognosis to the energy challenge is discussed. Areas of special emphasis included energy management, techniques for failure detection in energy related systems, improved prognostic techniques for energy related systems and opportunities for detection, diagnosis and prognosis in the energy field.
Homeland Security and Contraband Detection
NASA Astrophysics Data System (ADS)
Lanza, R. C.
Detection of contraband and illicit materials has become increasingly important, especially since the terrorist attacks in the United States on September 11, 2001. The nature of the detection problem embodies both physics issues and a set of operational constraints that limit the practical application of neutrons. The issue under consideration is detection of materials that are considered serious threats; these may include explosives; radioactive materials, fissile materials, and other materials associated with nuclear weapons, often referred to as special nuclear material (SNM). The overriding constraint is in the physics: systems must be based on clean physics; but unlike physics experiments, detection systems work under the limitation that materials must be identified nonintrusively, without interrupting the normal flow of commerce and with a high probability of detection and a low probability of false alarms. A great deal of work has been reported in the literature on neutron-based techniques for detecting explosives and drugs. The largest impetus by far for detecting explosives comes from aviation industry requirements for inspecting luggage and, to a lesser extent, cargo. The major alternative techniques are either X-ray-based or chemical trace detection methods that look for small traces of explosive residues. The limitations of the X-ray and trace methods in detecting explosives are well known, but currently (2008) it is safe to say that no neutron- or nuclear-based technique is being used routinely for security inspection, despite extensive development of these methods. Smuggling of nuclear materials has become a concern, and neutron techniques are particularly attractive for detecting them. Given the limitations of X-ray techniques and the need for SNM detection, it is now useful to reexamine neutron methodologies, particularly imaging. A significant number of neutron-based techniques have been proposed and are under development for security applications, especially SNM detection, but describing how they work is beyond the scope of the chapter. Instead, one particular approach to neutron imaging, neutron resonance radiography (NRR), is discussed in detail as it illustrates many of the issues connected with imaging and detection.
The detection of bulk explosives using nuclear-based techniques
DOE Office of Scientific and Technical Information (OSTI.GOV)
Morgado, R.E.; Gozani, T.; Seher, C.C.
1988-01-01
In 1986 we presented a rationale for the detection of bulk explosives based on nuclear techniques that addressed the requirements of civil aviation security in the airport environment. Since then, efforts have intensified to implement a system based on thermal neutron activation (TNA), with new work developing in fast neutron and energetic photon reactions. In this paper we will describe these techniques and present new results from laboratory and airport testing. Based on preliminary results, we contended in our earlier paper that nuclear-based techniques did provide sufficiently penetrating probes and distinguishable detectable reaction products to achieve the FAA operational goals;more » new data have supported this contention. The status of nuclear-based techniques for the detection of bulk explosives presently under investigation by the US Federal Aviation Administration (FAA) is reviewed. These include thermal neutron activation (TNA), fast neutron activation (FNA), the associated particle technique, nuclear resonance absorption, and photoneutron activation. The results of comprehensive airport testing of the TNA system performed during 1987-88 are summarized. From a technical point of view, nuclear-based techniques now represent the most comprehensive and feasible approach for meeting the operational criteria of detection, false alarms, and throughput. 9 refs., 5 figs., 2 tabs.« less
Chamnanpood, Chanpen; Sanguansermsri, Donruedee; Pongcharoen, Sutatip; Sanguansermsri, Phanchana
2011-03-01
Ten specific pathogen free (SPF) chickens were inoculated intranasally with avian influenza virus subtype H5N1. Evaluation revealed distribution of the virus in twelve organs: liver, intestine, bursa, lung, trachea, thymus, heart, pancreas, brain, spleen, kidney, and esophagus. Immunohistochemistry (IHC), chromogenic in situ hybridization (CISH), and real-time polymerase chain reaction (PCR) were developed and compared for detection of the virus from the organs. The distribution of avian influenza H5N1 in chickens varied by animal and detecting technique. The heart, kidneys, intestines, lungs, and pancreas were positive with all three techniques, while the others varied by techique. The three techniques can be used to detect avian influenza effectively, but the pros and cons of each technique need to be determined. The decision of which technique to use depends on the objective of the examination, budget, type and quality of samples, laboratory facilities and technician skills.
[Molecular genetics in chronic myeloid leukemia with variant Ph translocation].
Wu, Wei; Li, Jian-yong; Zhu, Yu; Qiu, Hai-rong; Pan, Jin-lan; Xu, Wei; Chen, Li-juan; Shen, Yun-feng; Xue, Yong-quan
2007-08-01
To explore the value of fluorescence in situ hybridization (FISH) and multiplex fluorescence in situ hybridization (M-FISH) techniques in the detection of genetic changes in chronic myeloid leukemia (CML) with variant Philadelphia translocation (vPh). Cytogenetic preparations from 10 CML patients with vPh confirmed by R banding were assayed with dual color dual fusion FISH technique. If only one fusion signal was detected in interphase cells, metaphase cells were observed to determine if there were derivative chromosome 9[der (9)] deletions. Meanwhile, the same cytogenetic preparations were assayed with M-FISH technique. Of the 10 CML patients with vPh, 5 were detected with der (9) deletions by FISH technique. M-FISH technique revealed that besides the chromosome 22, chromosomes 1, 3, 5, 6, 8, 10, 11 and 17 were also involved in the vPh. M-FISH technique also detected the abnormalities which were not found with conventional cytogenetics (CC), including two never reported abnormalities. The combination of CC, FISH and M-FISH technique could refine the genetic diagnosis of CML with vPh.
Azim, Riyasat; Li, Fangxing; Xue, Yaosuo; ...
2017-07-14
Distributed generations (DGs) for grid-connected applications require an accurate and reliable islanding detection methodology (IDM) for secure system operation. This paper presents an IDM for grid-connected inverter-based DGs. The proposed method is a combination of passive and active islanding detection techniques for aggregation of their advantages and elimination/minimisation of the drawbacks. In the proposed IDM, the passive method utilises critical system attributes extracted from local voltage measurements at target DG locations as well as employs decision tree-based classifiers for characterisation and detection of islanding events. The active method is based on Sandia frequency shift technique and is initiated only whenmore » the passive method is unable to differentiate islanding events from other system events. Thus, the power quality degradation introduced into the system by active islanding detection techniques can be minimised. Furthermore, a combination of active and passive techniques allows detection of islanding events under low power mismatch scenarios eliminating the disadvantage associated with the use of passive techniques alone. Finally, detailed case study results demonstrate the effectiveness of the proposed method in detection of islanding events under various power mismatch scenarios, load quality factors and in the presence of single or multiple grid-connected inverter-based DG units.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Azim, Riyasat; Li, Fangxing; Xue, Yaosuo
Distributed generations (DGs) for grid-connected applications require an accurate and reliable islanding detection methodology (IDM) for secure system operation. This paper presents an IDM for grid-connected inverter-based DGs. The proposed method is a combination of passive and active islanding detection techniques for aggregation of their advantages and elimination/minimisation of the drawbacks. In the proposed IDM, the passive method utilises critical system attributes extracted from local voltage measurements at target DG locations as well as employs decision tree-based classifiers for characterisation and detection of islanding events. The active method is based on Sandia frequency shift technique and is initiated only whenmore » the passive method is unable to differentiate islanding events from other system events. Thus, the power quality degradation introduced into the system by active islanding detection techniques can be minimised. Furthermore, a combination of active and passive techniques allows detection of islanding events under low power mismatch scenarios eliminating the disadvantage associated with the use of passive techniques alone. Finally, detailed case study results demonstrate the effectiveness of the proposed method in detection of islanding events under various power mismatch scenarios, load quality factors and in the presence of single or multiple grid-connected inverter-based DG units.« less
Reactive impinging-flow technique for polymer-electrolyte-fuel-cell electrode-defect detection
Zenyuk, Iryna V.; Englund, Nicholas; Bender, Guido; ...
2016-09-29
Reactive impinging flow (RIF) is a novel quality-control method for defect detection (i.e., reduction in Pt catalyst loading) in gas-diffusion electrodes (GDEs) on weblines. The technique uses infrared thermography to detect temperature of a nonflammable (<4% H 2) reactive mixture of H 2/O 2 in N 2 impinging and reacting on a Pt catalytic surface. In this article, different GDE size defects (with catalyst-loading reductions of 25, 50, and 100%) are detected at various webline speeds (3.048 and 9.144 m min -1) and gas flowrates (32.5 or 50 standard L min -1). Furthermore, a model is developed and validated formore » the technique, and it is subsequently used to optimize operating conditions and explore the applicability of the technique to a range of defects. The model suggests that increased detection can be achieved by recting more of the impinging H 2, which can be accomplished by placing blocking substrates on the top, bottom, or both of the GDE; placing a substrate on both results in a factor of four increase in the temperature differential, which is needed for smaller defect detection. Lastly, overall, the RIF technique is shown to be a promising route for in-line, high-speed, large-area detection of GDE defects on moving weblines.« less
Reactive impinging-flow technique for polymer-electrolyte-fuel-cell electrode-defect detection
NASA Astrophysics Data System (ADS)
Zenyuk, Iryna V.; Englund, Nicholas; Bender, Guido; Weber, Adam Z.; Ulsh, Michael
2016-11-01
Reactive impinging flow (RIF) is a novel quality-control method for defect detection (i.e., reduction in Pt catalyst loading) in gas-diffusion electrodes (GDEs) on weblines. The technique uses infrared thermography to detect temperature of a nonflammable (<4% H2) reactive mixture of H2/O2 in N2 impinging and reacting on a Pt catalytic surface. In this paper, different GDE size defects (with catalyst-loading reductions of 25, 50, and 100%) are detected at various webline speeds (3.048 and 9.144 m min-1) and gas flowrates (32.5 or 50 standard L min-1). Furthermore, a model is developed and validated for the technique, and it is subsequently used to optimize operating conditions and explore the applicability of the technique to a range of defects. The model suggests that increased detection can be achieved by recting more of the impinging H2, which can be accomplished by placing blocking substrates on the top, bottom, or both of the GDE; placing a substrate on both results in a factor of four increase in the temperature differential, which is needed for smaller defect detection. Overall, the RIF technique is shown to be a promising route for in-line, high-speed, large-area detection of GDE defects on moving weblines.
Preliminary study of the use of radiotracers for leak detection in industrial applications
NASA Astrophysics Data System (ADS)
Wetchagarun, S.; Petchrak, A.; Tippayakul, C.
2015-05-01
One of the most widespread uses of radiotracers in the industrial applications is the leak detection of the systems. This technique can be applied, for example, to detect leak in heat exchangers or along buried industrial pipelines. The ability to perform online investigation is one of the most important advantages of the radiotracer technique over other non-radioactive leak detection methods. In this paper, a preliminary study of the leak detection using radiotracer in the laboratory scale was presented. Br-82 was selected for this work due to its chemical property, its suitable half-life and its on-site availability. The NH4Br in the form of aqueous solution was injected into the experimental system as the radiotracer. Three NaI detectors were placed along the pipelines to measure system flow rate and to detect the leakage from the piping system. The results obtained from the radiotracer technique were compared to those measured by other methods. It is found that the flow rate obtained from the radiotracer technique agreed well with the one obtained from the flow meter. The leak rate result, however, showed discrepancy between results obtained from two different measuring methods indicating further study on leak detection was required before applying this technique in the industrial system.
Real time automatic detection of bearing fault in induction machine using kurtogram analysis.
Tafinine, Farid; Mokrani, Karim
2012-11-01
A proposed signal processing technique for incipient real time bearing fault detection based on kurtogram analysis is presented in this paper. The kurtogram is a fourth-order spectral analysis tool introduced for detecting and characterizing non-stationarities in a signal. This technique starts from investigating the resonance signatures over selected frequency bands to extract the representative features. The traditional spectral analysis is not appropriate for non-stationary vibration signal and for real time diagnosis. The performance of the proposed technique is examined by a series of experimental tests corresponding to different bearing conditions. Test results show that this signal processing technique is an effective bearing fault automatic detection method and gives a good basis for an integrated induction machine condition monitor.
A Simple Ultrasonic Experiment Using a Phase Shift Detection Technique.
ERIC Educational Resources Information Center
Yunus, W. Mahmood Mat; Ahmad, Maulana
1996-01-01
Describes a simple ultrasonic experiment that can be used to measure the purity of liquid samples by detecting variations in the velocity of sound. Uses a phase shift detection technique that incorporates the use of logic gates and a piezoelectric transducer. (JRH)
Comparison of survey techniques on detection of northern flying squirrels
Diggins, Corinne A.; Gilley, L. Michelle; Kelly, Christine A.; Ford, W. Mark
2016-01-01
The ability to detect a species is central to the success of monitoring for conservation and management purposes, especially if the species is rare or endangered. Traditional methods, such as live capture, can be labor-intensive, invasive, and produce low detection rates. Technological advances and new approaches provide opportunities to more effectively survey for species both in terms of accuracy and efficiency than previous methods. We conducted a pilot comparison study of a traditional technique (live-trapping) and 2 novel noninvasive techniques (camera-trapping and ultrasonic acoustic surveys) on detection rates of the federally endangered Carolina northern flying squirrel (Glaucomys sabrinus coloratus) in occupied habitat within the Roan Mountain Highlands of North Carolina, USA. In 2015, we established 3 5 × 5 live-trapping grids (6.5 ha) with 4 camera traps and 4 acoustic detectors systematically embedded in each grid. All 3 techniques were used simultaneously during 2 4-day survey periods. We compared techniques by assessing probability of detection (POD), latency to detection (LTD; i.e., no. of survey nights until initial detection), and survey effort. Acoustics had the greatest POD (0.37 ± 0.06 SE), followed by camera traps (0.30 ± 0.06) and live traps (0.01 ± 0.005). Acoustics had a lower LTD than camera traps (P = 0.017), where average LTD was 1.5 nights for acoustics and 3.25 nights for camera traps. Total field effort was greatest with live traps (111.9 hr) followed by acoustics (8.4 hr) and camera traps (9.6 hr), although processing and examination for data of noninvasive techniques made overall effort similar among the 3 methods. This pilot study demonstrated that both noninvasive methods were better rapid-assessment detection techniques for flying squirrels than live traps. However, determining seasonal effects between survey techniques and further development of protocols for both noninvasive techniques is necessary prior to widespread application in the region. Published 2016. This article is a U.S. Government work and is in the public domain in the USA.
Min-max hyperellipsoidal clustering for anomaly detection in network security.
Sarasamma, Suseela T; Zhu, Qiuming A
2006-08-01
A novel hyperellipsoidal clustering technique is presented for an intrusion-detection system in network security. Hyperellipsoidal clusters toward maximum intracluster similarity and minimum intercluster similarity are generated from training data sets. The novelty of the technique lies in the fact that the parameters needed to construct higher order data models in general multivariate Gaussian functions are incrementally derived from the data sets using accretive processes. The technique is implemented in a feedforward neural network that uses a Gaussian radial basis function as the model generator. An evaluation based on the inclusiveness and exclusiveness of samples with respect to specific criteria is applied to accretively learn the output clusters of the neural network. One significant advantage of this is its ability to detect individual anomaly types that are hard to detect with other anomaly-detection schemes. Applying this technique, several feature subsets of the tcptrace network-connection records that give above 95% detection at false-positive rates below 5% were identified.
Wang, Shi-ping; He, Xin; Zhou, Yun-fei
2015-12-01
Schistosomiasis is a type of zoonotic parasitosis that severely impairs human health. Rapid detection of infection sources is a key to the control of schistosomiasis. With the effective control of schistosomiasis in China, the detection techniques for infection sources have also been developed. The rate and the intensity of infection among humans and livestocks have been significantly decreased in China, as the control program has entered the transmission control stage in most of the endemic areas. Under this situation, the traditional etiological diagnosing techniques and common immunological methods can not afford rapid detection of infection sources of schistosomiasis. Instead, we are calling for detection methods with higher sensitivity, specificity and stability while being less time-consuming, more convenient and less costing. In recent years, many improved or novel detection methods have been applied for the epidemiological surveillance of schistosomiasis, such as the automatic scanning microscopic image acquisition system, PCR-ELISA, immunosensors, loop-mediated isothermal amplification, etc. The development of new monitoring techniques can facilitate rapid detection of schistosome infection sources in endemic areas.
Smith, Christopher D.; Quist, Michael C.; Hardy, Ryan S.
2015-01-01
Research comparing different sampling techniques helps improve the efficiency and efficacy of sampling efforts. We compared the effectiveness of three sampling techniques (small-mesh hoop nets, benthic trawls, boat-mounted electrofishing) for 30 species in the Green (WY, USA) and Kootenai (ID, USA) rivers by estimating conditional detection probabilities (probability of detecting a species given its presence at a site). Electrofishing had the highest detection probabilities (generally greater than 0.60) for most species (88%), but hoop nets also had high detectability for several taxa (e.g., adult burbot Lota lota, juvenile northern pikeminnow Ptychocheilus oregonensis). Benthic trawls had low detection probabilities (<0.05) for most taxa (84%). Gear-specific effects were present for most species indicating large differences in gear effectiveness among techniques. In addition to gear effects, habitat characteristics also influenced detectability of fishes. Most species-specific habitat relationships were idiosyncratic and reflected the ecology of the species. Overall findings of our study indicate that boat-mounted electrofishing and hoop nets are the most effective techniques for sampling fish assemblages in large, coldwater rivers.
Determination of a Limited Scope Network's Lightning Detection Efficiency
NASA Technical Reports Server (NTRS)
Rompala, John T.; Blakeslee, R.
2008-01-01
This paper outlines a modeling technique to map lightning detection efficiency variations over a region surveyed by a sparse array of ground based detectors. A reliable flash peak current distribution (PCD) for the region serves as the technique's base. This distribution is recast as an event probability distribution function. The technique then uses the PCD together with information regarding: site signal detection thresholds, type of solution algorithm used, and range attenuation; to formulate the probability that a flash at a specified location will yield a solution. Applying this technique to the full region produces detection efficiency contour maps specific to the parameters employed. These contours facilitate a comparative analysis of each parameter's effect on the network's detection efficiency. In an alternate application, this modeling technique gives an estimate of the number, strength, and distribution of events going undetected. This approach leads to a variety of event density contour maps. This application is also illustrated. The technique's base PCD can be empirical or analytical. A process for formulating an empirical PCD specific to the region and network being studied is presented. A new method for producing an analytical representation of the empirical PCD is also introduced.
Assessing the Rayleigh Intensity Remote Leak Detection Technique
NASA Technical Reports Server (NTRS)
Clements, Sandra
2001-01-01
Remote sensing technologies are being considered for efficient, low cost gas leak detection. An exploratory project to identify and evaluate remote sensing technologies for application to gas leak detection is underway. During Phase 1 of the project, completed last year, eleven specific techniques were identified for further study. One of these, the Rayleigh Intensity technique, would make use of changes in the light scattered off of gas molecules to detect and locate a leak. During the 10-week Summer Faculty Fellowship Program, the scatter of light off of gas molecules was investigated. The influence of light scattered off of aerosols suspended in the atmosphere was also examined to determine if this would adversely affect leak detection. Results of this study indicate that in unconditioned air, it will be difficult, though perhaps not impossible, to distinguish between a gas leak and natural variations in the aerosol content of the air. Because information about the particle size distribution in clean room environments is incomplete, the applicability in clean rooms is uncertain though more promising than in unconditioned environments. It is suggested that problems caused by aerosols may be overcome by using the Rayleigh Intensity technique in combination with another remote sensing technique, the Rayleigh Doppler technique.
NASA Astrophysics Data System (ADS)
Haider, A. F. M. Y.; Hedayet Ullah, M.; Khan, Z. H.; Kabir, Firoza; Abedin, K. M.
2014-03-01
LIBS technique coupled with adsorption has been applied for the efficient detection of arsenic in liquid. Several adsorbents like tea leaves, bamboo slice, charcoal and zinc oxide have been used to enable sensitive detection of arsenic presence in water using LIBS. Among these, zinc oxide and charcoal show the better results. The detection limits for arsenic in water were 1 ppm and 8 ppm, respectively, when ZnO and charcoal were used as adsorbents of arsenic. To date, the determination of 1 ppm of As in water is the lowest concentration of detected arsenic in water by the LIBS technique. The detection limit of As was lowered to even less than 100 ppb by a combination of LIBS technique, adsorption by ZnO and concentration enhancement technique. Using the combination of these three techniques the ultimate concentration of arsenic was found to be 0.083 ppm (83 ppb) for arsenic polluted water collected from a tube-well of Farajikandi union (longitude 90.64°, latitude 23.338° north) of Matlab Upozila of Chandpur district in Bangladesh. This result compares fairly well with the finding of arsenic concentration of 0.078 ppm in the sample by the AAS technique at the Bangladesh Council of Scientific and Industrial Research (BCSIR) lab. Such a low detection limit (1 ppm) of trace elements in liquid matrix has significantly enhanced the scope of LIBS as an analytical tool.
A survey of landmine detection using hyperspectral imaging
NASA Astrophysics Data System (ADS)
Makki, Ihab; Younes, Rafic; Francis, Clovis; Bianchi, Tiziano; Zucchetti, Massimo
2017-02-01
Hyperspectral imaging is a trending technique in remote sensing that finds its application in many different areas, such as agriculture, mapping, target detection, food quality monitoring, etc. This technique gives the ability to remotely identify the composition of each pixel of the image. Therefore, it is a natural candidate for the purpose of landmine detection, thanks to its inherent safety and fast response time. In this paper, we will present the results of several studies that employed hyperspectral imaging for the purpose of landmine detection, discussing the different signal processing techniques used in this framework for hyperspectral image processing and target detection. Our purpose is to highlight the progresses attained in the detection of landmines using hyperspectral imaging and to identify possible perspectives for future work, in order to achieve a better detection in real-time operation mode.
Thermal neutron detector based on COTS CMOS imagers and a conversion layer containing Gadolinium
NASA Astrophysics Data System (ADS)
Pérez, Martín; Blostein, Juan Jerónimo; Bessia, Fabricio Alcalde; Tartaglione, Aureliano; Sidelnik, Iván; Haro, Miguel Sofo; Suárez, Sergio; Gimenez, Melisa Lucía; Berisso, Mariano Gómez; Lipovetzky, Jose
2018-06-01
In this work we will introduce a novel low cost position sensitive thermal neutron detection technique, based on a Commercial Off The Shelf CMOS image sensor covered with a Gadolinium containing conversion layer. The feasibility of the neutron detection technique implemented in this work has been experimentally demonstrated. A thermal neutron detection efficiency of 11.3% has been experimentally obtained with a conversion layer of 11.6 μm. It was experimentally verified that the thermal neutron detection efficiency of this technique is independent on the intensity of the incident thermal neutron flux, which was confirmed for conversion layers of different thicknesses. Based on the experimental results, a spatial resolution better than 25 μm is expected. This spatial resolution makes the proposed technique specially useful for neutron beam characterization, neutron beam dosimetry, high resolution neutron imaging, and several neutron scattering techniques.
Kataoka, Tomoya; Hinata, Hirofumi; Kako, Shin'ichiro
2012-09-01
We have developed a technique for detecting the pixels of colored macro plastic debris (plastic pixels) using photographs taken by a webcam installed on Sodenohama beach, Tobishima Island, Japan. The technique involves generating color references using a uniform color space (CIELUV) to detect plastic pixels and removing misdetected pixels by applying a composite image method. This technique demonstrated superior performance in terms of detecting plastic pixels of various colors compared to the previous method which used the lightness values in the CIELUV color space. We also obtained a 10-month time series of the quantity of plastic debris by combining a projective transformation with this technique. By sequential monitoring of plastic debris quantity using webcams, it is possible to clean up beaches systematically, to clarify the transportation processes of plastic debris in oceans and coastal seas and to estimate accumulation rates on beaches. Copyright © 2012 Elsevier Ltd. All rights reserved.
Structural Damage Detection Using Virtual Passive Controllers
NASA Technical Reports Server (NTRS)
Lew, Jiann-Shiun; Juang, Jer-Nan
2001-01-01
This paper presents novel approaches for structural damage detection which uses the virtual passive controllers attached to structures, where passive controllers are energy dissipative devices and thus guarantee the closed-loop stability. The use of the identified parameters of various closed-loop systems can solve the problem that reliable identified parameters, such as natural frequencies of the open-loop system may not provide enough information for damage detection. Only a small number of sensors are required for the proposed approaches. The identified natural frequencies, which are generally much less sensitive to noise and more reliable than the identified natural frequencies, are used for damage detection. Two damage detection techniques are presented. One technique is based on the structures with direct output feedback controllers while the other technique uses the second-order dynamic feedback controllers. A least-squares technique, which is based on the sensitivity of natural frequencies to damage variables, is used for accurately identifying the damage variables.
Brensinger, Karen; Rollman, Christopher; Copper, Christine; Genzman, Ashton; Rine, Jacqueline; Lurie, Ira; Moini, Mehdi
2016-01-01
To address the need for the forensic analysis of high explosives, a novel capillary electrophoresis mass spectrometry (CE-MS) technique has been developed for high resolution, sensitivity, and mass accuracy detection of these compounds. The technique uses perfluorooctanoic acid (PFOA) as both a micellar electrokinetic chromatography (MEKC) reagent for separation of neutral explosives and as the complexation reagent for mass spectrometric detection of PFOA-explosive complexes in the negative ion mode. High explosives that formed complexes with PFOA included RDX, HMX, tetryl, and PETN. Some nitroaromatics were detected as molecular ions. Detection limits in the high parts per billion range and linear calibration responses over two orders of magnitude were obtained. For proof of concept, the technique was applied to the quantitative analysis of high explosives in sand samples. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Recombinase polymerase amplification applied to plant virus detection and potential implications.
Babu, Binoy; Ochoa-Corona, Francisco M; Paret, Mathews L
2018-04-01
Several isothermal techniques for the detection of plant pathogens have been developed with the advent of molecular techniques. Among them, Recombinase Polymerase Amplification (RPA) is becoming an important technique for the rapid, sensitive and cost-effective detection of plant viruses. The RPA technology has the advantage to be implemented in field-based scenarios because the method requires a minimal sample preparation, and is performed at constant low temperature (37-42 °C). The RPA technique is rapidly becoming a promising tool for use in rapid detection and further diagnostics in plant clinics and monitoring quarantine services. This paper presents a review of studies conducted using RPA for detection/diagnosis of plant viruses with either DNA genomes (Banana bunchy top virus, Bean golden yellow mosaic virus, Tomato mottle virus, Tomato yellow leaf curl virus) or RNA genomes (Little Cherry virus 2, Plum pox virus and Rose rosette virus). Copyright © 2018 Elsevier Inc. All rights reserved.
Transient Faults in Computer Systems
NASA Technical Reports Server (NTRS)
Masson, Gerald M.
1993-01-01
A powerful technique particularly appropriate for the detection of errors caused by transient faults in computer systems was developed. The technique can be implemented in either software or hardware; the research conducted thus far primarily considered software implementations. The error detection technique developed has the distinct advantage of having provably complete coverage of all errors caused by transient faults that affect the output produced by the execution of a program. In other words, the technique does not have to be tuned to a particular error model to enhance error coverage. Also, the correctness of the technique can be formally verified. The technique uses time and software redundancy. The foundation for an effective, low-overhead, software-based certification trail approach to real-time error detection resulting from transient fault phenomena was developed.
Detection of genetically modified organisms in foods by DNA amplification techniques.
García-Cañas, Virginia; Cifuentes, Alejandro; González, Ramón
2004-01-01
In this article, the different DNA amplification techniques that are being used for detecting genetically modified organisms (GMOs) in foods are examined. This study intends to provide an updated overview (including works published till June 2002) on the principal applications of such techniques together with their main advantages and drawbacks in GMO detection in foods. Some relevant facts on sampling, DNA isolation, and DNA amplification methods are discussed. Moreover; these analytical protocols are discuissed from a quantitative point of view, including the newest investigations on multiplex detection of GMOs in foods and validation of methods.
NASA Astrophysics Data System (ADS)
Zink, Frank Edward
The detection and classification of pulmonary nodules is of great interest in chest radiography. Nodules are often indicative of primary cancer, and their detection is particularly important in asymptomatic patients. The ability to classify nodules as calcified or non-calcified is important because calcification is a positive indicator that the nodule is benign. Dual-energy methods offer the potential to improve both the detection and classification of nodules by allowing the formation of material-selective images. Tissue-selective images can improve detection by virtue of the elimination of obscuring rib structure. Bone -selective images are essentially calcium images, allowing classification of the nodule. A dual-energy technique is introduced which uses a computed radiography system to acquire dual-energy chest radiographs in a single-exposure. All aspects of the dual-energy technique are described, with particular emphasis on scatter-correction, beam-hardening correction, and noise-reduction algorithms. The adaptive noise-reduction algorithm employed improves material-selective signal-to-noise ratio by up to a factor of seven with minimal sacrifice in selectivity. A clinical comparison study is described, undertaken to compare the dual-energy technique to conventional chest radiography for the tasks of nodule detection and classification. Observer performance data were collected using the Free Response Observer Characteristic (FROC) method and the bi-normal Alternative FROC (AFROC) performance model. Results of the comparison study, analyzed using two common multiple observer statistical models, showed that the dual-energy technique was superior to conventional chest radiography for detection of nodules at a statistically significant level (p < .05). Discussion of the comparison study emphasizes the unique combination of data collection and analysis techniques employed, as well as the limitations of comparison techniques in the larger context of technology assessment.
Orr, Christopher Henry; Luff, Craig Janson; Dockray, Thomas; Macarthur, Duncan Whittemore; Bounds, John Alan; Koster, James E.
2001-01-01
The apparatus and method provide an improved technique for detecting ions as the area from which ions are attracted to a detector is increased, consequently increasing the number of ions detected. This is achieved by providing the outer electrodes of the detector connected to the electrical potential, together with alternate intermediate electrodes. The other intermediate electrodes and preferably the housing are grounded. The technique renders such detection techniques more sensitive and gives them a lower threshold at which they can function.
Projective techniques and the detection of child sexual abuse.
Garb, H N; Wood, J M; Nezworski, M T
2000-05-01
Projective techniques (e.g., the Rorschach, Human Figure Drawings) are sometimes used to detect child sexual abuse. West recently conducted a meta-analysis on this topic, but she systematically excluded nonsignificant results. In this article, a reanalysis of her data is presented. The authors conclude that projective techniques should not be used to detect child sexual abuse. Many of the studies purportedly demonstrating validity are flawed, and none of the projective test scores have been well replicated.
Peng, Lan; Cao, Xuan; Xiong, Bin; He, Yan; Yeung, Edward S
2016-06-18
We reported a novel scattering switch-on detection technique using flash-lamp polarization darkfield microscopy (FLPDM) for target-induced plasmon-coupling based sensing in homogeneous solution. With this method, we demonstrated sub-nM sensitivity for hydrogen sulfide (H2S) detection over a dynamic range of five orders of magnitude. This robust technique holds great promise for applications in toxic environmental pollutants and biological molecules.
Enhanced automatic artifact detection based on independent component analysis and Renyi's entropy.
Mammone, Nadia; Morabito, Francesco Carlo
2008-09-01
Artifacts are disturbances that may occur during signal acquisition and may affect their processing. The aim of this paper is to propose a technique for automatically detecting artifacts from the electroencephalographic (EEG) recordings. In particular, a technique based on both Independent Component Analysis (ICA) to extract artifactual signals and on Renyi's entropy to automatically detect them is presented. This technique is compared to the widely known approach based on ICA and the joint use of kurtosis and Shannon's entropy. The novel processing technique is shown to detect on average 92.6% of the artifactual signals against the average 68.7% of the previous technique on the studied available database. Moreover, Renyi's entropy is shown to be able to detect muscle and very low frequency activity as well as to discriminate them from other kinds of artifacts. In order to achieve an efficient rejection of the artifacts while minimizing the information loss, future efforts will be devoted to the improvement of blind artifact separation from EEG in order to ensure a very efficient isolation of the artifactual activity from any signals deriving from other brain tasks.
Bansod, BabanKumar; Kumar, Tejinder; Thakur, Ritula; Rana, Shakshi; Singh, Inderbir
2017-08-15
Heavy metal ions are non-biodegradable and contaminate most of the natural resources occurring in the environment including water. Some of the heavy metals including Lead (Pb), Mercury (Hg), Arsenic (As), Chromium (Cr) and Cadmium (Cd) are considered to be highly toxic and hazardous to human health even at trace levels. This leads to the requirement of fast, accurate and reliable techniques for the detection of heavy metal ions. This review presents various electrochemical detection techniques for heavy metal ions those are user friendly, low cost, provides on-site and real time monitoring as compared to other spectroscopic and optical techniques. The categorization of different electrochemical techniques is done on the basis of different types of detection signals generated due to presence of heavy metal ions in the solution matrix like current, potential, conductivity, electrochemical impedance, and electrochemiluminescence. Also, the recent trends in electrochemical detection of heavy metal ions with various types of sensing platforms including metals, metal films, metal oxides, nanomaterials, carbon nano tubes, polymers, microspheres and biomaterials have been evoked. Copyright © 2017 Elsevier B.V. All rights reserved.
Potential Biomarkers and Their Applications for Rapid and Reliable Detection of Malaria
Jain, Priyamvada; Chakma, Babina; Patra, Sanjukta; Goswami, Pranab
2014-01-01
Malaria has been responsible for the highest mortality in most malaria endemic countries. Even after decades of malaria control campaigns, it still persists as a disease of high mortality due to improper diagnosis and rapidly evolving drug resistant malarial parasites. For efficient and economical malaria management, WHO recommends that all malaria suspected patients should receive proper diagnosis before administering drugs. It is thus imperative to develop fast, economical, and accurate techniques for diagnosis of malaria. In this regard an in-depth knowledge on malaria biomarkers is important to identify an appropriate biorecognition element and utilize it prudently to develop a reliable detection technique for diagnosis of the disease. Among the various biomarkers, plasmodial lactate dehydrogenase and histidine-rich protein II (HRP II) have received increasing attention for developing rapid and reliable detection techniques for malaria. The widely used rapid detection tests (RDTs) for malaria succumb to many drawbacks which promotes exploration of more efficient economical detection techniques. This paper provides an overview on the current status of malaria biomarkers, along with their potential utilization for developing different malaria diagnostic techniques and advanced biosensors. PMID:24804253
Detecting Position Using ARKit
ERIC Educational Resources Information Center
Dilek, Ufuk; Erol, Mustafa
2018-01-01
Developed by using ARKit, a novel app which can be used to detect position in physics experiments was introduced. The ARKit relies on a new technique. The result of the experiment presented in this study was satisfactory, suggesting that the new technique can be employed in position detection experiments/demonstrations that are conducted using…
USDA-ARS?s Scientific Manuscript database
Nondestructive methods based on fluorescence hyperspectral imaging (HSI) techniques were developed in order to detect worms on fresh-cut lettuce. The optimal wavebands for detecting worms on fresh-cut lettuce were investigated using the one-way ANOVA analysis and correlation analysis. The worm detec...
Extrasolar Planets in the Classroom
ERIC Educational Resources Information Center
George, Samuel J.
2011-01-01
The field of extrasolar planets is still, in comparison with other astrophysical topics, in its infancy. There have been about 300 or so extrasolar planets detected and their detection has been accomplished by various different techniques. Here we present a simple laboratory experiment to show how planets are detected using the transit technique.…
Detection of proteolytic activity by covalent tethering of fluorogenic substrates in zymogram gels.
Deshmukh, Ameya A; Weist, Jessica L; Leight, Jennifer L
2018-05-01
Current zymographic techniques detect only a subset of known proteases due to the limited number of native proteins that have been optimized for incorporation into polyacrylamide gels. To address this limitation, we have developed a technique to covalently incorporate fluorescently labeled, protease-sensitive peptides using an azido-PEG3-maleimide crosslinker. Peptides incorporated into gels enabled measurement of MMP-2, -9, -14, and bacterial collagenase. Sensitivity analysis demonstrated that use of peptide functionalized gels could surpass detection limits of current techniques. Finally, electrophoresis of conditioned media from cultured cells resulted in the appearance of several proteolytic bands, some of which were undetectable by gelatin zymography. Taken together, these results demonstrate that covalent incorporation of fluorescent substrates can greatly expand the library of detectable proteases using zymographic techniques.
Current trends in explosive detection techniques.
Caygill, J Sarah; Davis, Frank; Higson, Seamus P J
2012-01-15
The detection of explosives and explosive-related compounds has become a heightened priority in recent years for homeland security and counter-terrorism applications. There has been a huge increase in research within this area-through both the development of new, innovative detection approaches and the improvement of existing techniques. Developments for miniaturisation, portability, field-ruggedisation and improvements in stand-off distances, selectivity and sensitivity have been necessary to develop and improve techniques. This review provides a consolidation of information relating to recent advances in explosive detection techniques without being limited to one specific research area or explosive type. The focus of this review will be towards advances in the last 5 years, with the reader being referred to earlier reviews where appropriate. Copyright © 2011. Published by Elsevier B.V.
NASA Astrophysics Data System (ADS)
Spicer, James B.; Dagdigian, Paul; Osiander, Robert; Miragliotta, Joseph A.; Zhang, Xi-Cheng; Kersting, Roland; Crosley, David R.; Hanson, Ronald K.; Jeffries, Jay
2003-09-01
The research center established by Army Research Office under the Multidisciplinary University Research Initiative program pursues a multidisciplinary approach to investigate and advance the use of complementary analytical techniques for sensing of explosives and/or explosive-related compounds as they occur in the environment. The techniques being investigated include Terahertz (THz) imaging and spectroscopy, Laser-Induced Breakdown Spectroscopy (LIBS), Cavity Ring Down Spectroscopy (CRDS) and Resonance Enhanced Multiphoton Ionization (REMPI). This suite of techniques encompasses a diversity of sensing approaches that can be applied to detection of explosives in condensed phases such as adsorbed species in soil or can be used for vapor phase detection above the source. Some techniques allow for remote detection while others have highly specific and sensitive analysis capabilities. This program is addressing a range of fundamental, technical issues associated with trace detection of explosive related compounds using these techniques. For example, while both LIBS and THz can be used to carry-out remote analysis of condensed phase analyte from a distance in excess several meters, the sensitivities of these techniques to surface adsorbed explosive-related compounds are not currently known. In current implementations, both CRDS and REMPI require sample collection techniques that have not been optimized for environmental applications. Early program elements will pursue the fundamental advances required for these techniques including signature identification for explosive-related compounds/interferents and trace analyte extraction. Later program tasks will explore simultaneous application of two or more techniques to assess the benefits of sensor fusion.
Standoff laser-based spectroscopy for explosives detection
NASA Astrophysics Data System (ADS)
Gaft, M.; Nagli, L.
2007-10-01
Real time detection and identification of explosives at a standoff distance is a major issue in efforts to develop defense against so-called Improvised Explosive Devices (IED). It is recognized that the only technique, which is potentially capable to standoff detection of minimal amounts of explosives is laser-based spectroscopy. LDS activity is based on a combination of laser-based spectroscopic methods with orthogonal capabilities. Our technique belongs to trace detection, namely to its micro-particles variety. It is based on commonly held belief that surface contamination was very difficult to avoid and could be exploited for standoff detection. We has applied optical techniques including gated Raman and time-resolved luminescence spectroscopy for detection of main explosive materials, both factory and homemade. We developed and tested a Raman system for the field remote detection and identification of minimal amounts of explosives on relevant surfaces at a distance of up to 30 meters.
The Outlier Detection for Ordinal Data Using Scalling Technique of Regression Coefficients
NASA Astrophysics Data System (ADS)
Adnan, Arisman; Sugiarto, Sigit
2017-06-01
The aims of this study is to detect the outliers by using coefficients of Ordinal Logistic Regression (OLR) for the case of k category responses where the score from 1 (the best) to 8 (the worst). We detect them by using the sum of moduli of the ordinal regression coefficients calculated by jackknife technique. This technique is improved by scalling the regression coefficients to their means. R language has been used on a set of ordinal data from reference distribution. Furthermore, we compare this approach by using studentised residual plots of jackknife technique for ANOVA (Analysis of Variance) and OLR. This study shows that the jackknifing technique along with the proper scaling may lead us to reveal outliers in ordinal regression reasonably well.
Comparison of conditional sampling and averaging techniques in a turbulent boundary layer
NASA Astrophysics Data System (ADS)
Subramanian, C. S.; Rajagopalan, S.; Antonia, R. A.; Chambers, A. J.
1982-10-01
A rake of cold wires was used in a slightly heated boundary layer to identify coherent temperature fronts. An X-wire/cold-wire arrangement was used simultaneously with the rake to provide measurements of the longitudinal and normal velocity fluctuations and temperature fluctuations. Conditional averages of these parameters and their products were obtained by application of conditional techniques (VITA, HOLE, BT, RA1, and RA3) based on the detection of temperature fronts using information obtained at only one point in space. It is found that none of the one-point detection techniques is in good quantitative agreement with the rake detection technique, the largest correspondence being 51%. Despite the relatively poor correspondence between the conditional techniques, these techniques, with the exception of HOLE, produce conditional averages that are in reasonable qualitative agreement with those deduced using the rake.
Holographic radar imaging privacy techniques utilizing dual-frequency implementation
NASA Astrophysics Data System (ADS)
McMakin, Douglas L.; Hall, Thomas E.; Sheen, David M.
2008-04-01
Over the last 15 years, the Pacific Northwest National Laboratory has performed significant research and development activities to enhance the state of the art of holographic radar imaging systems to be used at security checkpoints for screening people for concealed threats hidden under their garments. These enhancement activities included improvements to privacy techniques to remove human features and providing automatic detection of body-worn concealed threats. The enhanced privacy and detection methods used both physical and software imaging techniques. The physical imaging techniques included polarization-diversity illumination and reception, dual-frequency implementation, and high-frequency imaging at 60 GHz. Software imaging techniques to enhance the privacy of the person under surveillance included extracting concealed threat artifacts from the imagery to automatically detect the threat. This paper will focus on physical privacy techniques using dual-frequency implementation.
Holographic Radar Imaging Privacy Techniques Utilizing Dual-Frequency Implementation
DOE Office of Scientific and Technical Information (OSTI.GOV)
McMakin, Douglas L.; Hall, Thomas E.; Sheen, David M.
2008-04-18
Over the last 15 years, the Pacific Northwest National Laboratory has performed significant research and development activities to enhance the state of the art of holographic radar imaging systems to be used at security checkpoints for screening people for concealed threats hidden under their garments. These enhancement activities included improvements to privacy techniques to remove human features and providing automatic detection of body-worn concealed threats. The enhanced privacy and detection methods used both physical and software imaging techniques. The physical imaging techniques included polarization-diversity illumination and reception, dual-frequency implementation, and high-frequency imaging at 60 GHz. Software imaging techniques to enhancemore » the privacy of the person under surveillance included extracting concealed threat artifacts from the imagery to automatically detect the threat. This paper will focus on physical privacy techniques using dual-frequency implementation.« less
Jean, Julie; Blais, Burton; Darveau, André; Fliss, Ismaïl
2001-01-01
A nucleic acid sequence-based amplification (NASBA) technique for the detection of hepatitis A virus (HAV) in foods was developed and compared to the traditional reverse transcription (RT)-PCR technique. Oligonucleotide primers targeting the VP1 and VP2 genes encoding the major HAV capsid proteins were used for the amplification of viral RNA in an isothermal process resulting in the accumulation of RNA amplicons. Amplicons were detected by hybridization with a digoxigenin-labeled oligonucleotide probe in a dot blot assay format. Using the NASBA, as little as 0.4 ng of target RNA/ml was detected per comparison to 4 ng/ml for RT-PCR. When crude HAV viral lysate was used, a detection limit of 2 PFU (4 × 102 PFU/ml) was obtained with NASBA, compared to 50 PFU (1 × 104 PFU/ml) obtained with RT-PCR. No interference was encountered in the amplification of HAV RNA in the presence of excess nontarget RNA or DNA. The NASBA system successfully detected HAV recovered from experimentally inoculated samples of waste water, lettuce, and blueberries. Compared to RT-PCR and other amplification techniques, the NASBA system offers several advantages in terms of sensitivity, rapidity, and simplicity. This technique should be readily adaptable for detection of other RNA viruses in both foods and clinical samples. PMID:11722911
Jean, J; Blais, B; Darveau, A; Fliss, I
2001-12-01
A nucleic acid sequence-based amplification (NASBA) technique for the detection of hepatitis A virus (HAV) in foods was developed and compared to the traditional reverse transcription (RT)-PCR technique. Oligonucleotide primers targeting the VP1 and VP2 genes encoding the major HAV capsid proteins were used for the amplification of viral RNA in an isothermal process resulting in the accumulation of RNA amplicons. Amplicons were detected by hybridization with a digoxigenin-labeled oligonucleotide probe in a dot blot assay format. Using the NASBA, as little as 0.4 ng of target RNA/ml was detected per comparison to 4 ng/ml for RT-PCR. When crude HAV viral lysate was used, a detection limit of 2 PFU (4 x 10(2) PFU/ml) was obtained with NASBA, compared to 50 PFU (1 x 10(4) PFU/ml) obtained with RT-PCR. No interference was encountered in the amplification of HAV RNA in the presence of excess nontarget RNA or DNA. The NASBA system successfully detected HAV recovered from experimentally inoculated samples of waste water, lettuce, and blueberries. Compared to RT-PCR and other amplification techniques, the NASBA system offers several advantages in terms of sensitivity, rapidity, and simplicity. This technique should be readily adaptable for detection of other RNA viruses in both foods and clinical samples.
Neuroimaging techniques for memory detection: scientific, ethical, and legal issues.
Meegan, Daniel V
2008-01-01
There is considerable interest in the use of neuroimaging techniques for forensic purposes. Memory detection techniques, including the well-publicized Brain Fingerprinting technique (Brain Fingerprinting Laboratories, Inc., Seattle WA), exploit the fact that the brain responds differently to sensory stimuli to which it has been exposed before. When a stimulus is specifically associated with a crime, the resulting brain activity should differentiate between someone who was present at the crime and someone who was not. This article reviews the scientific literature on three such techniques: priming, old/new, and P300 effects. The forensic potential of these techniques is evaluated based on four criteria: specificity, automaticity, encoding flexibility, and longevity. This article concludes that none of the techniques are devoid of forensic potential, although much research is yet to be done. Ethical issues, including rights to privacy and against self-incrimination, are discussed. A discussion of legal issues concludes that current memory detection techniques do not yet meet United States standards of legal admissibility.
2010-02-01
overview of their respective national up-date. Dr. Roy presented a new technique for evaluating the bioaerosol particle size based on a multiple...Field-of-View LIDAR technique . Mr. Levesque from INO gave an overview of their expertise in LIDAR and biophotonics. Dr. Chin from Laval University gave... techniques have the potential to detect particulate aerosols remotely at distances of many kilometres [1]. They can provide spatially resolved
Hydroacoustic basis for detection and characterization of eelgrass (Zostera marina)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sabol, B.; McCarthy, E.; Rocha, K.
1997-06-01
Understanding the distribution and density of seagrasses is important for a variety of environmental applications. Physical techniques for detection and characterization are labor and cost intensive and provide little insight into spatial distribution. optical-based techniques are limited by water clarity - frequently resulting in systematic underestimation of the extent of seagrasses. Active hydroacoustic techniques have shown the ability to detect seagrasses but the phenomenology behind detection is poorly understood. Laboratory and in-situ hydroacoustic measurements are presented for eelgrass (Zostera marina), a common seagrass in the United States. Based on these data, hydroacoustic approaches for wide area detection and mapping aremore » discussed and several are demonstrated within areas of established eelgrass beds in Narragansett Bay, Rhode Island.« less
A coherent detection technique via optically biased field for broadband terahertz radiation.
Du, Hai-Wei; Dong, Jia-Meng; Liu, Yi; Shi, Chang-Cheng; Wu, Jing-Wei; Peng, Xiao-Yu
2017-09-01
We demonstrate theoretically and experimentally a coherent terahertz detection technique based on an optically biased field functioning as a local oscillator and a second harmonic induced by the terahertz electric field in the air sensor working in free space. After optimizing the polarization angle and the energy of the probe pulse, and filling the system with dry nitrogen, the terahertz radiation generated from a two-color-femtosecond-laser-pulses induced plasma filament is measured by this technique with a bandwidth of 0.1-10 THz and a signal-to-noise ratio of 48 dB. Our technique provides an alternative simple method for coherent broadband terahertz detection.
The use of geoscience methods for terrestrial forensic searches
NASA Astrophysics Data System (ADS)
Pringle, J. K.; Ruffell, A.; Jervis, J. R.; Donnelly, L.; McKinley, J.; Hansen, J.; Morgan, R.; Pirrie, D.; Harrison, M.
2012-08-01
Geoscience methods are increasingly being utilised in criminal, environmental and humanitarian forensic investigations, and the use of such methods is supported by a growing body of experimental and theoretical research. Geoscience search techniques can complement traditional methodologies in the search for buried objects, including clandestine graves, weapons, explosives, drugs, illegal weapons, hazardous waste and vehicles. This paper details recent advances in search and detection methods, with case studies and reviews. Relevant examples are given, together with a generalised workflow for search and suggested detection technique(s) table. Forensic geoscience techniques are continuing to rapidly evolve to assist search investigators to detect hitherto difficult to locate forensic targets.
Screening and Biosensor-Based Approaches for Lung Cancer Detection
Wang, Lulu
2017-01-01
Early diagnosis of lung cancer helps to reduce the cancer death rate significantly. Over the years, investigators worldwide have extensively investigated many screening modalities for lung cancer detection, including computerized tomography, chest X-ray, positron emission tomography, sputum cytology, magnetic resonance imaging and biopsy. However, these techniques are not suitable for patients with other pathologies. Developing a rapid and sensitive technique for early diagnosis of lung cancer is urgently needed. Biosensor-based techniques have been recently recommended as a rapid and cost-effective tool for early diagnosis of lung tumor markers. This paper reviews the recent development in screening and biosensor-based techniques for early lung cancer detection. PMID:29065541
Material-specific detection and classification of single nanoparticles
Person, Steven; Deutsch, Bradley; Mitra, Anirban; Novotny, Lukas
2010-01-01
Detection and classification of nanoparticles is important for environmental monitoring, contamination mitigation, biological label tracking, and bio-defense. Detection techniques involve a trade-off between sensitivity, discrimination, and speed. This paper presents a material-specific dual-color common-path interferometric detection system. Two wavelengths are simultaneously used to discriminate between 60 nm silver and 80 nm diameter gold particles in solution with a detection time of τ ≈ 1 ms. The detection technique is applicable to situations where both particle size and material are of interest. PMID:21142033
Nuclear technologies for explosives detection
NASA Astrophysics Data System (ADS)
Bell, Curtis J.
1992-12-01
This paper presents an exploration of several techniques for detection of Improvised Explosive Devices (IED) using interactions of specific nuclei with gammarays or fast neutrons. Techniques considered use these interactions to identify the device by measuring the densities and/or relative concentrations of the elemental constituents of explosives. These techniques are to be compared with selected other nuclear and non-nuclear methods. Combining of nuclear and non-nuclear techniques will also be briefly discussed.
Image processing techniques for noise removal, enhancement and segmentation of cartilage OCT images
NASA Astrophysics Data System (ADS)
Rogowska, Jadwiga; Brezinski, Mark E.
2002-02-01
Osteoarthritis, whose hallmark is the progressive loss of joint cartilage, is a major cause of morbidity worldwide. Recently, optical coherence tomography (OCT) has demonstrated considerable promise for the assessment of articular cartilage. Among the most important parameters to be assessed is cartilage width. However, detection of the bone cartilage interface is critical for the assessment of cartilage width. At present, the quantitative evaluations of cartilage thickness are being done using manual tracing of cartilage-bone borders. Since data is being obtained near video rate with OCT, automated identification of the bone-cartilage interface is critical. In order to automate the process of boundary detection on OCT images, there is a need for developing new image processing techniques. In this paper we describe the image processing techniques for speckle removal, image enhancement and segmentation of cartilage OCT images. In particular, this paper focuses on rabbit cartilage since this is an important animal model for testing both chondroprotective agents and cartilage repair techniques. In this study, a variety of techniques were examined. Ultimately, by combining an adaptive filtering technique with edge detection (vertical gradient, Sobel edge detection), cartilage edges can be detected. The procedure requires several steps and can be automated. Once the cartilage edges are outlined, the cartilage thickness can be measured.
Chromatography in the detection and characterization of illegal pharmaceutical preparations.
Deconinck, Eric; Sacré, Pierre-Yves; Courselle, Patricia; De Beer, Jacques O
2013-09-01
Counterfeit and illegal pharmaceutical products are an increasing worldwide problem and constitute a major challenge for analytical laboratories to detect and characterize them. Spectroscopic techniques such as infrared spectroscopy and Raman spectroscopy have always been the first methods of choice to detect counterfeits and illegal preparations, but due to the evolution in the seized products and the necessity of risk assessment, chromatographic methods are becoming more important in this domain. This review intends to give a general overview of the techniques described in literature to characterize counterfeit and illegal pharmaceutical preparations, focusing on the role of chromatographic techniques with different detection tools.
NASA Astrophysics Data System (ADS)
Reber, E. E.; Foote, F. B.; Schellenbaum, R. L.; Bradley, R. G.
1981-07-01
The potential of radiometric imaging technique to detect shielded nuclear materials and explosives carried covertly by personnel was investigated. This method of detecting contraband depends upon the differences in emissivity and reflectivity of the contraband relative to human tissue. Explosives, unlike metals and metal composites, generally have high emissivities and low reflectivities that closely approximate those of human tissue making explosives difficult to detect. Samples of several common types of explosives (TNT, Detasheet, C4, and several types of water gels) were examined at the 1.4- and 3-mm wavelengths using active and passive radiometeric techniques.
Multimodal technique to eliminate humidity interference for specific detection of ethanol.
Jalal, Ahmed Hasnain; Umasankar, Yogeswaran; Gonzalez, Pablo J; Alfonso, Alejandro; Bhansali, Shekhar
2017-01-15
Multimodal electrochemical technique incorporating both open circuit potential (OCP) and amperometric techniques have been conceptualized and implemented to improve the detection of specific analyte in systems where more than one analyte is present. This approach has been demonstrated through the detection of ethanol while eliminating the contribution of water in a micro fuel cell sensor system. The sensor was interfaced with LMP91000 potentiostat, controlled through MSP430F5529LP microcontroller to implement an auto-calibration algorithm tailored to improve the detection of alcohol. The sensor was designed and fabricated as a three electrode system with Nafion as a proton exchange membrane (PEM). The electrochemical signal of the interfering phase (water) was eliminated by implementing the multimodal electrochemical detection technique. The results were validated by comparing sensor and potentiostat performances with a commercial sensor and potentiostat respectively. The results suggest that such a sensing system can detect ethanol at concentrations as low as 5ppm. The structure and properties such as low detection limit, selectivity and miniaturized size enables potential application of this device in wearable transdermal alcohol measurements. Copyright © 2016 Elsevier B.V. All rights reserved.
Sensor data fusion for spectroscopy-based detection of explosives
NASA Astrophysics Data System (ADS)
Shah, Pratik V.; Singh, Abhijeet; Agarwal, Sanjeev; Sedigh, Sahra; Ford, Alan; Waterbury, Robert
2009-05-01
In-situ trace detection of explosive compounds such as RDX, TNT, and ammonium nitrate, is an important problem for the detection of IEDs and IED precursors. Spectroscopic techniques such as LIBS and Raman have shown promise for the detection of residues of explosive compounds on surfaces from standoff distances. Individually, both LIBS and Raman techniques suffer from various limitations, e.g., their robustness and reliability suffers due to variations in peak strengths and locations. However, the orthogonal nature of the spectral and compositional information provided by these techniques makes them suitable candidates for the use of sensor fusion to improve the overall detection performance. In this paper, we utilize peak energies in a region by fitting Lorentzian or Gaussian peaks around the location of interest. The ratios of peak energies are used for discrimination, in order to normalize the effect of changes in overall signal strength. Two data fusion techniques are discussed in this paper. Multi-spot fusion is performed on a set of independent samples from the same region based on the maximum likelihood formulation. Furthermore, the results from LIBS and Raman sensors are fused using linear discriminators. Improved detection performance with significantly reduced false alarm rates is reported using fusion techniques on data collected for sponsor demonstration at Fort Leonard Wood.
Sample detection and analysis techniques for electrophoretic separation
NASA Technical Reports Server (NTRS)
Falb, R. D.; Hughes, K. E.; Powell, T. R.
1975-01-01
Methods for detecting and analyzing biological agents suitable for space flight operations were studied primarily by literature searches which were conducted of cell separation techniques. Detection methods discussed include: photometrometric, electric, radiometric, micrometry, ultrasonic, microscopic, and photographic. A bibliography, and a directory of vendors are included along with an index of commercial hardware.
Detection of submicron scale cracks and other surface anomalies using positron emission tomography
Cowan, Thomas E.; Howell, Richard H.; Colmenares, Carlos A.
2004-02-17
Detection of submicron scale cracks and other mechanical and chemical surface anomalies using PET. This surface technique has sufficient sensitivity to detect single voids or pits of sub-millimeter size and single cracks or fissures of millimeter size; and single cracks or fissures of millimeter-scale length, micrometer-scale depth, and nanometer-scale length, micrometer-scale depth, and nanometer-scale width. This technique can also be applied to detect surface regions of differing chemical reactivity. It may be utilized in a scanning or survey mode to simultaneously detect such mechanical or chemical features over large interior or exterior surface areas of parts as large as about 50 cm in diameter. The technique involves exposing a surface to short-lived radioactive gas for a time period, removing the excess gas to leave a partial monolayer, determining the location and shape of the cracks, voids, porous regions, etc., and calculating the width, depth, and length thereof. Detection of 0.01 mm deep cracks using a 3 mm detector resolution has been accomplished using this technique.
Wong, Y-P; Othman, S; Lau, Y-L; Radu, S; Chee, H-Y
2018-03-01
Loop-mediated isothermal amplification (LAMP) amplifies DNA with high specificity, efficiency and rapidity under isothermal conditions by using a DNA polymerase with high displacement strand activity and a set of specifically designed primers to amplify targeted DNA strands. Following its first discovery by Notomi et al. ( Nucleic Acids Res 28: E63), LAMP was further developed over the years which involved the combination of this technique with other molecular approaches, such as reverse transcription and multiplex amplification for the detection of infectious diseases caused by micro-organisms in humans, livestock and plants. In this review, available types of LAMP techniques will be discussed together with their applications in detection of various micro-organisms. Up to date, there are varieties of LAMP detection methods available including colorimetric and fluorescent detection, real-time monitoring using turbidity metre and detection using lateral flow device which will also be highlighted in this review. Apart from that, commercialization of LAMP technique had also been reported such as lyophilized form of LAMP reagents kit and LAMP primer sets for detection of pathogenic micro-organisms. On top of that, advantages and limitations of this molecular detection method are also described together with its future potential as a diagnostic method for infectious disease. © 2017 The Society for Applied Microbiology.
Payne, Gemma; Reedy, Brian; Lennard, Chris; Comber, Bruce; Exline, David; Roux, Claude
2005-05-28
This study investigated the application of chemical imaging to the detection of latent fingerprints using the Condor macroscopic chemical imaging system (ChemImage Corp., Pittsburgh, USA). Methods were developed and optimised for the visualisation of untreated latent fingerprints and fingerprints processed with DFO, ninhydrin, cyanoacrylate, and cyanoacrylate plus rhodamine 6G stain. The results obtained with chemical imaging were compared to the detection achieved using conventional imaging techniques. The Condor significantly improved the detection of many prints, especially those that might be considered poor quality or borderline prints. Prints on newspaper treated with ninhydrin and DFO, and prints on white and yellow paper treated with ninhydrin, benefited the most from chemical imaging detection. In many cases, fingerprints undetectable using conventional imaging techniques could be visualised with chemical imaging. Ridge detail from untreated prints on yellow paper was also detected using the Condor. When prints of high quality were examined, both detection techniques produced quality results. The results of this project demonstrate that chemical imaging offers advantages over conventional visualisation techniques when examining latent fingerprints, especially those that would be considered difficult, such as weak prints or prints on surfaces that produce highly luminescent backgrounds. Standard testing procedures for the detection and enhancement of fingerprints by chemical imaging are presented and discussed.
Invariant domain watermarking using heaviside function of order alpha and fractional Gaussian field.
Abbasi, Almas; Woo, Chaw Seng; Ibrahim, Rabha Waell; Islam, Saeed
2015-01-01
Digital image watermarking is an important technique for the authentication of multimedia content and copyright protection. Conventional digital image watermarking techniques are often vulnerable to geometric distortions such as Rotation, Scaling, and Translation (RST). These distortions desynchronize the watermark information embedded in an image and thus disable watermark detection. To solve this problem, we propose an RST invariant domain watermarking technique based on fractional calculus. We have constructed a domain using Heaviside function of order alpha (HFOA). The HFOA models the signal as a polynomial for watermark embedding. The watermark is embedded in all the coefficients of the image. We have also constructed a fractional variance formula using fractional Gaussian field. A cross correlation method based on the fractional Gaussian field is used for watermark detection. Furthermore the proposed method enables blind watermark detection where the original image is not required during the watermark detection thereby making it more practical than non-blind watermarking techniques. Experimental results confirmed that the proposed technique has a high level of robustness.
Invariant Domain Watermarking Using Heaviside Function of Order Alpha and Fractional Gaussian Field
Abbasi, Almas; Woo, Chaw Seng; Ibrahim, Rabha Waell; Islam, Saeed
2015-01-01
Digital image watermarking is an important technique for the authentication of multimedia content and copyright protection. Conventional digital image watermarking techniques are often vulnerable to geometric distortions such as Rotation, Scaling, and Translation (RST). These distortions desynchronize the watermark information embedded in an image and thus disable watermark detection. To solve this problem, we propose an RST invariant domain watermarking technique based on fractional calculus. We have constructed a domain using Heaviside function of order alpha (HFOA). The HFOA models the signal as a polynomial for watermark embedding. The watermark is embedded in all the coefficients of the image. We have also constructed a fractional variance formula using fractional Gaussian field. A cross correlation method based on the fractional Gaussian field is used for watermark detection. Furthermore the proposed method enables blind watermark detection where the original image is not required during the watermark detection thereby making it more practical than non-blind watermarking techniques. Experimental results confirmed that the proposed technique has a high level of robustness. PMID:25884854
A Real-Time Earthquake Precursor Detection Technique Using TEC from a GPS Network
NASA Astrophysics Data System (ADS)
Alp Akyol, Ali; Arikan, Feza; Arikan, Orhan
2016-07-01
Anomalies have been observed in the ionospheric electron density distribution prior to strong earthquakes. However, most of the reported results are obtained by earthquake analysis. Therefore, their implementation in practice is highly problematic. Recently, a novel earthquake precursor detection technique based on spatio-temporal analysis of Total Electron Content (TEC) data obtained from Turkish National Permanent GPS Network (TNPGN) is developed by IONOLAB group (www.ionolab.org). In the present study, the developed detection technique is implemented in a causal setup over the available data set in test phase that enables the real time implementation. The performance of the developed earthquake prediction technique is evaluated by using 10 fold cross validation over the data obtained in 2011. Among the 23 earthquakes that have magnitudes higher than 5, the developed technique can detect precursors of 14 earthquakes while producing 8 false alarms. This study is supported by TUBITAK 115E915 and Joint TUBITAK 114E092 and AS CR 14/001 projects.
Biosensing Using Magnetic Particle Detection Techniques
Chen, Yi-Ting; Kolhatkar, Arati G.; Zenasni, Oussama; Xu, Shoujun
2017-01-01
Magnetic particles are widely used as signal labels in a variety of biological sensing applications, such as molecular detection and related strategies that rely on ligand-receptor binding. In this review, we explore the fundamental concepts involved in designing magnetic particles for biosensing applications and the techniques used to detect them. First, we briefly describe the magnetic properties that are important for bio-sensing applications and highlight the associated key parameters (such as the starting materials, size, functionalization methods, and bio-conjugation strategies). Subsequently, we focus on magnetic sensing applications that utilize several types of magnetic detection techniques: spintronic sensors, nuclear magnetic resonance (NMR) sensors, superconducting quantum interference devices (SQUIDs), sensors based on the atomic magnetometer (AM), and others. From the studies reported, we note that the size of the MPs is one of the most important factors in choosing a sensing technique. PMID:28994727
Recent technological advancements in tuberculosis diagnostics - A review.
Gupta, Shagun; Kakkar, Vipan
2018-09-15
Early diagnosis and on-time effective treatment are indispensable for Tuberculosis (TB) control - a life threatening infectious communicable disease. The conventional techniques for diagnosing TB normally take two to three weeks. This delay in diagnosis and further increase in detection complexity due to the emerging risks of XDR-TB (Extensively drug Resistant-TB) and MDR-TB (Multidrug Resistant-TB) are evoking interest of researchers in the field of developing rapid TB detection techniques such as biosensing and other point-of-care (POC) techniques. Biosensing technologies along with the collaboration with nanotechnology have enormous potential to boost the MTB detection and for overall management in clinical diagnosis. A diverse range of portable, sensitive and rapid biosensors based on different signal transducer principles and with different biomarkers detection capabilities have been developed for TB detection in the early stages. Further, a lot of progress has been achieved over the years in developing various point-of-care diagnostic tools including non-molecular methods and molecular techniques. The objective of this study is to present a succinct review of the available TB detection techniques that are either in use or under development. The focus of this review is on the current developments occurred in nano-biosensing technologies. A synopsis of ameliorations in different non-molecular diagnostic tools and progress in the field of molecular techniques along with the role of emerging Lab-on-Chip technology for diagnosing and mitigating the TB consequences have also been presented. Copyright © 2018 Elsevier B.V. All rights reserved.
A lightweight network anomaly detection technique
Kim, Jinoh; Yoo, Wucherl; Sim, Alex; ...
2017-03-13
While the network anomaly detection is essential in network operations and management, it becomes further challenging to perform the first line of detection against the exponentially increasing volume of network traffic. In this paper, we develop a technique for the first line of online anomaly detection with two important considerations: (i) availability of traffic attributes during the monitoring time, and (ii) computational scalability for streaming data. The presented learning technique is lightweight and highly scalable with the beauty of approximation based on the grid partitioning of the given dimensional space. With the public traffic traces of KDD Cup 1999 andmore » NSL-KDD, we show that our technique yields 98.5% and 83% of detection accuracy, respectively, only with a couple of readily available traffic attributes that can be obtained without the help of post-processing. Finally, the results are at least comparable with the classical learning methods including decision tree and random forest, with approximately two orders of magnitude faster learning performance.« less
A lightweight network anomaly detection technique
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, Jinoh; Yoo, Wucherl; Sim, Alex
While the network anomaly detection is essential in network operations and management, it becomes further challenging to perform the first line of detection against the exponentially increasing volume of network traffic. In this paper, we develop a technique for the first line of online anomaly detection with two important considerations: (i) availability of traffic attributes during the monitoring time, and (ii) computational scalability for streaming data. The presented learning technique is lightweight and highly scalable with the beauty of approximation based on the grid partitioning of the given dimensional space. With the public traffic traces of KDD Cup 1999 andmore » NSL-KDD, we show that our technique yields 98.5% and 83% of detection accuracy, respectively, only with a couple of readily available traffic attributes that can be obtained without the help of post-processing. Finally, the results are at least comparable with the classical learning methods including decision tree and random forest, with approximately two orders of magnitude faster learning performance.« less
Updating Landsat-derived land-cover maps using change detection and masking techniques
NASA Technical Reports Server (NTRS)
Likens, W.; Maw, K.
1982-01-01
The California Integrated Remote Sensing System's San Bernardino County Project was devised to study the utilization of a data base at a number of jurisdictional levels. The present paper discusses the implementation of change-detection and masking techniques in the updating of Landsat-derived land-cover maps. A baseline landcover classification was first created from a 1976 image, then the adjusted 1976 image was compared with a 1979 scene by the techniques of (1) multidate image classification, (2) difference image-distribution tails thresholding, (3) difference image classification, and (4) multi-dimensional chi-square analysis of a difference image. The union of the results of methods 1, 3 and 4 was used to create a mask of possible change areas between 1976 and 1979, which served to limit analysis of the update image and reduce comparison errors in unchanged areas. The techniques of spatial smoothing of change-detection products, and of combining results of difference change-detection algorithms are also shown to improve Landsat change-detection accuracies.
Biosensors and their applications in detection of organophosphorus pesticides in the environment.
Hassani, Shokoufeh; Momtaz, Saeideh; Vakhshiteh, Faezeh; Maghsoudi, Armin Salek; Ganjali, Mohammad Reza; Norouzi, Parviz; Abdollahi, Mohammad
2017-01-01
This review discusses the past and recent advancements of biosensors focusing on detection of organophosphorus pesticides (OPs) due to their exceptional use during the last decades. Apart from agricultural benefits, OPs also impose adverse toxicological effects on animal and human population. Conventional approaches such as chromatographic techniques used for pesticide detection are associated with several limitations. A biosensor technology is unique due to the detection sensitivity, selectivity, remarkable performance capabilities, simplicity and on-site operation, fabrication and incorporation with nanomaterials. This study also provided specifications of the most OPs biosensors reported until today based on their transducer system. In addition, we highlighted the application of advanced complementary materials and analysis techniques in OPs detection systems. The availability of these new materials associated with new sensing techniques has led to introduction of easy-to-use analytical tools of high sensitivity and specificity in the design and construction of OPs biosensors. In this review, we elaborated the achievements in sensing systems concerning innovative nanomaterials and analytical techniques with emphasis on OPs.
Marín, M-J; Figuero, E; González, I; O'Connor, A; Diz, P; Álvarez, M; Herrera, D; Sanz, M
2016-05-01
The prevalence and amounts of periodontal pathogens detected in bacteraemia samples after tooth brushing-induced by means of four diagnostic technique, three based on culture and one in a molecular-based technique, have been compared in this study. Blood samples were collected from thirty-six subjects with different periodontal status (17 were healthy, 10 with gingivitis and 9 with periodontitis) at baseline and 2 minutes after tooth brushing. Each sample was analyzed by three culture-based methods [direct anaerobic culturing (DAC), hemo-culture (BACTEC), and lysis-centrifugation (LC)] and one molecular-based technique [quantitative polymerase chain reaction (qPCR)]. With culture any bacterial isolate was detected and quantified, while with qPCR only Porphyromonas gingivalis and Aggregatibacter actinomycetemcomitans were detected and quantified. Descriptive analyses, ANOVA and Chi-squared tests, were performed. Neither BACTEC nor qPCR detected any type of bacteria in the blood samples. Only LC (2.7%) and DAC (8.3%) detected bacteraemia, although not in the same patients. Fusobacterium nucleatum was the most frequently detected bacterial species. The disparity in the results when the same samples were analyzed with four different microbiological detection methods highlights the need for a proper validation of the methodology to detect periodontal pathogens in bacteraemia samples, mainly when the presence of periodontal pathogens in blood samples after tooth brushing was very seldom.
Chirathaworn, Chintana; Janwitthayanan, Weena; Sereemaspun, Amornpun; Lertpocasombat, Kanchalee; Rungpanich, Utane; Ekpo, Pattama; Suwancharoen, Duangjai
2014-04-01
Detection of antibody specific to Leptospira by various immunological techniques has been used for leptospirosis diagnosis. However, the sensitivity of antibody detection during the first few days after infection is low. Molecular techniques are suggested to provide earlier diagnosis than antibody detection, but a rapid and easy to perform assay for Leptospira antigen detection would provide an additional useful tool for disease diagnosis. In this study, we coupled gold nanoparticles with antibody to LipL32, a protein commonly found in pathogenic Leptospira. This coupled gold reagent was used in the immunochromatographic strip for Leptospira detection. We demonstrated that the sensitivity of Leptospira detection by this strip was 10(3) ml(-1). There was no positive result detected when strips were tested with non-pathogenic Leptospira, Staphylococcus aureus, Streptococcus group B, Acinetobacter baumannii, Escherichia coli, Salmonella typhi, Klebsiella pneumoniae, Enterococcus faecalis or Enterococcus faecium. These data suggest that gold nanoparticles coupled with antibody to LipL32 could be used for Leptospira detection by a rapid test based on an immunochromatographic technique.
Detection of Glaucoma Using Image Processing Techniques: A Critique.
Kumar, B Naveen; Chauhan, R P; Dahiya, Nidhi
2018-01-01
The primary objective of this article is to present a summary of different types of image processing methods employed for the detection of glaucoma, a serious eye disease. Glaucoma affects the optic nerve in which retinal ganglion cells become dead, and this leads to loss of vision. The principal cause is the increase in intraocular pressure, which occurs in open-angle and angle-closure glaucoma, the two major types affecting the optic nerve. In the early stages of glaucoma, no perceptible symptoms appear. As the disease progresses, vision starts to become hazy, leading to blindness. Therefore, early detection of glaucoma is needed for prevention. Manual analysis of ophthalmic images is fairly time-consuming and accuracy depends on the expertise of the professionals. Automatic analysis of retinal images is an important tool. Automation aids in the detection, diagnosis, and prevention of risks associated with the disease. Fundus images obtained from a fundus camera have been used for the analysis. Requisite pre-processing techniques have been applied to the image and, depending upon the technique, various classifiers have been used to detect glaucoma. The techniques mentioned in the present review have certain advantages and disadvantages. Based on this study, one can determine which technique provides an optimum result.
Thermographic techniques and adapted algorithms for automatic detection of foreign bodies in food
NASA Astrophysics Data System (ADS)
Meinlschmidt, Peter; Maergner, Volker
2003-04-01
At the moment foreign substances in food are detected mainly by using mechanical and optical methods as well as ultrasonic technique and than they are removed from the further process. These techniques detect a large portion of the foreign substances due to their different mass (mechanical sieving), their different colour (optical method) and their different surface density (ultrasonic detection). Despite the numerous different methods a considerable portion of the foreign substances remain undetected. In order to recognise materials still undetected, a complementary detection method would be desirable removing the foreign substances not registered by the a.m. methods from the production process. In a project with 13 partner from the food industry, the Fraunhofer - Institut für Holzforschung (WKI) and the Technische Unsiversität are trying to adapt thermography for the detection of foreign bodies in the food industry. After the initial tests turned out to be very promising for the differentiation of food stuffs and foreign substances, more and detailed investigation were carried out to develop suitable algorithms for automatic detection of foreign bodies. In order to achieve -besides the mere visual detection of foreign substances- also an automatic detection under production conditions, numerous experiences in image processing and pattern recognition are exploited. Results for the detection of foreign bodies will be presented at the conference showing the different advantages and disadvantages of using grey - level, statistical and morphological image processing techniques.
NASA Astrophysics Data System (ADS)
Antolín-Urbaneja, J. C.; Eguizabal, I.; Briz, N.; Dominguez, A.; Estensoro, P.; Secchi, A.; Varriale, A.; Di Giovanni, S.; D'Auria, S.
2013-05-01
Several techniques for detecting chemical drug precursors have been developed in the last decade. Most of them are able to identify molecules at very low concentration under lab conditions. Other commercial devices are able to detect a fixed number and type of target substances based on a single detection technique providing an absence of flexibility with respect to target compounds. The construction of compact and easy to use detection systems providing screening for a large number of compounds being able to discriminate them with low false alarm rate and high probability of detection is still an open concern. Under CUSTOM project, funded by the European Commission within the FP7, a stand-alone portable sensing device based on multiple techniques is being developed. One of these techniques is based on the LED induced fluorescence polarization to detect Ephedrine and Benzyl Methyl Keton (BMK) as a first approach. This technique is highly selective with respect to the target compounds due to the generation of properly engineered fluorescent proteins which are able to bind the target analytes, as it happens in an "immune-type reaction". This paper deals with the advances in the design, construction and validation of the LED induced fluorescence sensor to detect BMK analytes. This sensor includes an analysis module based on high performance LED and PMT detector, a fluidic system to dose suitable quantities of reagents and some printed circuit boards, all of them fixed in a small structure (167mm × 193mm × 228mm) with the capability of working as a stand-alone application.
Detection of cracks beneath rivet heads via pulsed eddy current technique
NASA Astrophysics Data System (ADS)
Giguère, J. S. R.; Lepine, B. A.; Dubois, J. M. S.
2002-05-01
Improving the detectability of fatigue cracks under installed fasteners is one of the many goals of the aging aircraft nondestructive evaluation (NDE) community. The pulsed eddy current offers new capabilities to address this requirement. The aim of the paper is to evaluate the potential of this technique for detecting and quantifying notches under installed fasteners.
Data-Mining Techniques in Detecting Factors Linked to Academic Achievement
ERIC Educational Resources Information Center
Martínez Abad, Fernando; Chaparro Caso López, Alicia A.
2017-01-01
In light of the emergence of statistical analysis techniques based on data mining in education sciences, and the potential they offer to detect non-trivial information in large databases, this paper presents a procedure used to detect factors linked to academic achievement in large-scale assessments. The study is based on a non-experimental,…
Camouflage target detection via hyperspectral imaging plus information divergence measurement
NASA Astrophysics Data System (ADS)
Chen, Yuheng; Chen, Xinhua; Zhou, Jiankang; Ji, Yiqun; Shen, Weimin
2016-01-01
Target detection is one of most important applications in remote sensing. Nowadays accurate camouflage target distinction is often resorted to spectral imaging technique due to its high-resolution spectral/spatial information acquisition ability as well as plenty of data processing methods. In this paper, hyper-spectral imaging technique together with spectral information divergence measure method is used to solve camouflage target detection problem. A self-developed visual-band hyper-spectral imaging device is adopted to collect data cubes of certain experimental scene before spectral information divergences are worked out so as to discriminate target camouflage and anomaly. Full-band information divergences are measured to evaluate target detection effect visually and quantitatively. Information divergence measurement is proved to be a low-cost and effective tool for target detection task and can be further developed to other target detection applications beyond spectral imaging technique.
NASA Technical Reports Server (NTRS)
Buechler, W.; Tucker, A. G.
1981-01-01
Several methods were employed to detect both the occurrence and source of errors in the operational software of the AN/SLQ-32. A large embedded real time electronic warfare command and control system for the ROLM 1606 computer are presented. The ROLM computer provides information about invalid addressing, improper use of privileged instructions, stack overflows, and unimplemented instructions. Additionally, software techniques were developed to detect invalid jumps, indices out of range, infinte loops, stack underflows, and field size errors. Finally, data are saved to provide information about the status of the system when an error is detected. This information includes I/O buffers, interrupt counts, stack contents, and recently passed locations. The various errors detected, techniques to assist in debugging problems, and segment simulation on a nontarget computer are discussed. These error detection techniques were a major factor in the success of finding the primary cause of error in 98% of over 500 system dumps.
Nuclear quadrupole resonance detection of explosives: an overview
NASA Astrophysics Data System (ADS)
Miller, Joel B.
2011-06-01
Nuclear Quadrupole Resonance (NQR) is a spectroscopic technique closely related to Nuclear Magnetic Resonance (NMR) and Magnetic Resonance Imaging (MRI). These techniques, and NQR in particular, induce signals from the material being interrogated that are very specific to the chemical and physical structure of the material, but are relatively insensitive to the physical form of the material. NQR explosives detection exploits this specificity to detect explosive materials, in contrast to other well known techniques that are designed to detect explosive devices. The past two decades have seen a large research and development effort in NQR explosives detection in the United States aimed at transportation security and military applications. Here, I will briefly describe the physical basis for NQR before discussing NQR developments over the past decade, with particular emphasis on landmine detection and the use of NQR in combating IED's. Potential future directions for NQR research and development are discussed.
Methods and systems for remote detection of gases
Johnson, Timothy J.
2007-11-27
Novel systems and methods for remotely detecting at least one constituent of a gas via infrared detection are provided. A system includes at least one extended source of broadband infrared radiation and a spectrally sensitive receiver positioned remotely from the source. The source and the receiver are oriented such that a surface of the source is in the field of view of the receiver. The source includes a heating component thermally coupled to the surface, and the heating component is configured to heat the surface to a temperature above ambient temperature. The receiver is operable to collect spectral infrared absorption data representative of a gas present between the source and the receiver. The invention advantageously overcomes significant difficulties associated with active infrared detection techniques known in the art, and provides an infrared detection technique with a much greater sensitivity than passive infrared detection techniques known in the art.
Methods and systems for remote detection of gases
Johnson, Timothy J
2012-09-18
Novel systems and methods for remotely detecting at least one constituent of a gas via infrared detection are provided. A system includes at least one extended source of broadband infrared radiation and a spectrally sensitive receiver positioned remotely from the source. The source and the receiver are oriented such that a surface of the source is in the field of view of the receiver. The source includes a heating component thermally coupled to the surface, and the heating component is configured to heat the surface to a temperature above ambient temperature. The receiver is operable to collect spectral infrared absorption data representative of a gas present between the source and the receiver. The invention advantageously overcomes significant difficulties associated with active infrared detection techniques known in the art, and provides an infrared detection technique with a much greater sensitivity than passive infrared detection techniques known in the art.
Development of a noninvasive technique for the measurement of intracranial pressure
NASA Technical Reports Server (NTRS)
Ueno, T.; Shuer, L. M.; Yost, W. T.; Hargens, A. R.
1998-01-01
Intracranial pressure (ICP) dynamics are important for understanding adjustments to altered gravity. Previous flight observations document significant facial edema during exposure to microgravity, which suggests that ICP is elevated during microgravity. However, there are no experimental results obtained during space flight, primarily due to the invasiveness of currently available techniques. We have developed and refined a noninvasive technique to measure intracranial pressure noninvasively. The technique is based upon detecting skull movements of a few micrometers in association with altered intracranial pressure. We reported that the PPLL technique has enough sensitivity to detect changes in cranial distance associated with the pulsation of ICP in cadavera. In normal operations, however, we place a transducer on the scalp. Thus, we cannot rule out the possibility that the PPLL technique picks up cutaneous pulsation. The purpose of the present study was therefore to show that the PPLL technique has enough sensitivity to detect changes in cranial distance associated with cardiac cycles in vivo.
NASA Technical Reports Server (NTRS)
1976-01-01
Analytic techniques have been developed for detecting and identifying abrupt changes in dynamic systems. The GLR technique monitors the output of the Kalman filter and searches for the time that the failure occured, thus allowing it to be sensitive to new data and consequently increasing the chances for fast system recovery following detection of a failure. All failure detections are based on functional redundancy. Performance tests of the F-8 aircraft flight control system and computerized modelling of the technique are presented.
Fundamentals of electrochemical detection techniques for CE and MCE.
Kubán, Pavel; Hauser, Peter C
2009-10-01
The electroanalytical techniques of amperometry, conductometry and potentiometry match well with the instrumental simplicity of CE. Indeed, all three detection approaches have been reported for electrophoretic separations. However, the characteristics of the three methods are quite distinct and these are not related to the optical methods more commonly employed. A detailed discussion of the underlying principles of each is given. The issue of possible effects of the separation voltage on the electrochemical detection techniques is considered in depth, and approaches to the elimination of such interferences are also discussed for each case.
Benchtop Antigen Detection Technique using Nanofiltration and Fluorescent Dyes
NASA Technical Reports Server (NTRS)
Scardelletti, Maximilian C.; Varaljay, Vanessa
2009-01-01
The designed benchtop technique is primed to detect bacteria and viruses from antigenic surface marker proteins in solutions, initially water. This inclusive bio-immunoassay uniquely combines nanofiltration and near infrared (NIR) dyes conjugated to antibodies to isolate and distinguish microbial antigens, using laser excitation and spectrometric analysis. The project goals include detecting microorganisms aboard the International Space Station, space shuttle, Crew Exploration Vehicle (CEV), and human habitats on future Moon and Mars missions, ensuring astronaut safety. The technique is intended to improve and advance water contamination testing both commercially and environmentally as well. Lastly, this streamlined technique poses to greatly simplify and expedite testing of pathogens in complex matrices, such as blood, in hospital and laboratory clinics.
The 'sniffer-patch' technique for detection of neurotransmitter release.
Allen, T G
1997-05-01
A wide variety of techniques have been employed for the detection and measurement of neurotransmitter release from biological preparations. Whilst many of these methods offer impressive levels of sensitivity, few are able to combine sensitivity with the necessary temporal and spatial resolution required to study quantal release from single cells. One detection method that is seeing a revival of interest and has the potential to fill this niche is the so-called 'sniffer-patch' technique. In this article, specific examples of the practical aspects of using this technique are discussed along with the procedures involved in calibrating these biosensors to extend their applications to provide quantitative, in addition to simple qualitative, measurements of quantal transmitter release.
Multiscale corner detection and classification using local properties and semantic patterns
NASA Astrophysics Data System (ADS)
Gallo, Giovanni; Giuoco, Alessandro L.
2002-05-01
A new technique to detect, localize and classify corners in digital closed curves is proposed. The technique is based on correct estimation of support regions for each point. We compute multiscale curvature to detect and to localize corners. As a further step, with the aid of some local features, it's possible to classify corners into seven distinct types. Classification is performed using a set of rules, which describe corners according to preset semantic patterns. Compared with existing techniques, the proposed approach inscribes itself into the family of algorithms that try to explain the curve, instead of simple labeling. Moreover, our technique works in manner similar to what is believed are typical mechanisms of human perception.
Arsenic detection in water: YPO{sub 4}:Eu{sup 3+} nanoparticles
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ghosh, Debasish; Luwang, Meitram Niraj, E-mail: mn.luwang@ncl.res.in; Academy of Scientific and Innovative Research
This work reports on the novel technique of detection of arsenic in aqueous solution utilising the luminescence properties of lanthanide doped nanomaterials. Eu{sup 3+} (5%) doped YPO{sub 4}nanorodswere utilised for the said experiment. Co-precipitation method was used for the synthesis of the materials and characterised them with different instrumental techniques like X-ray diffraction (XRD), Infra-red (IR), UV-absorption, scanning electron microscope (SEM), transmission electron microscope (TEM), X-ray photoelectron spectroscopy (XPS) and photoluminescence studies. This nanoparticle can adsorb both arsenic and arsenious acids. We studied the effect of arsenic adsorption on the luminescence behaviour of the nanoparticles. Arsenic acid enhanced the luminescencemore » intensity whereas arsenious acid quenched the luminescence. This luminescence enhancement or quenching is related with arsenic concentration. This relation of luminescence property with concentration of arsenic can be used to detect arsenic in industrial waste. - Graphical abstract: Novel technique of detection of Arsenic ion in aqueous solution utilising the luminescence properties of lanthanide doped nanomaterials. Potential application for detection of arsenic in drinking and industrial waste water. - Highlights: • Novel technique of detection of Arsenic in aqueous solution by YPO{sub 4}:Eu{sup 3+} nanomaterials. • The effect of arsenic adsorption on the luminescence behaviour of the nanoparticles was studied. • Arsenic acid enhance whereas arsenious acid quenches the luminescence intensity. • This technique can be used to detect arsenic in industrial waste.« less
Mohammadniaei, Mohsen; Yoon, Jinho; Lee, Taek; Choi, Jeong-Woo
2018-05-20
We fabricated a microRNA biosensor using the combination of surface enhanced Raman spectroscopy (SERS) and electrochemical (EC) techniques. For the first time, the weaknesses of each techniques for microRNA detection was compensated by the other ones to give rise to the specific and wide-range detection of miR-155. A single stranded 3' methylene blue (MB) and 5' thiol-modified RNA (MB-ssRNA-SH) was designed to detect the target miR-155 and immobilized onto the gold nanoparticle-modified ITO (ITO/GNP). Upon the invasion of target strand, the double-stranded RNA transformed rapidly to an upright structure resulting in a notable decrease in SERS and redox signals of the MB. For the first time, by combination of SERS and EC techniques in a single platform we extended the dynamic range of both techniques from 10 pM to 450 nM (SERS: 10 pM-5 nM and EC: 5 nM-450 nM). As well, the SERS technique improved the detection limit of the EC method from 100 pM to 100 fM, while the EC method covered single-mismatch detection which was the SERS deficiency. The fabricated single-step biosensor possessing a good capability of miRNA detection in human serum, could be employed throughout the broad ranges of biomedical and bioelectronics applications. Copyright © 2018 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Guidang, Excel Philip B.; Llanda, Christopher John R.; Palaoag, Thelma D.
2018-03-01
Face Detection Technique as a strategy in controlling a multimedia instructional material was implemented in this study. Specifically, it achieved the following objectives: 1) developed a face detection application that controls an embedded mother-tongue-based instructional material for face-recognition configuration using Python; 2) determined the perceptions of the students using the Mutt Susan’s student app review rubric. The study concludes that face detection technique is effective in controlling an electronic instructional material. It can be used to change the method of interaction of the student with an instructional material. 90% of the students perceived the application to be a great app and 10% rated the application to be good.
Change Detection Analysis of Water Pollution in Coimbatore Region using Different Color Models
NASA Astrophysics Data System (ADS)
Jiji, G. Wiselin; Devi, R. Naveena
2017-12-01
The data acquired through remote sensing satellites furnish facts about the land and water at varying resolutions and has been widely used for several change detection studies. Apart from the existence of many change detection methodologies and techniques, emergence of new ones continues to subsist. Existing change detection techniques exploit images that are either in gray scale or RGB color model. In this paper we introduced color models for performing change detection for water pollution. Here the polluted lakes are classified and post-classification change detection techniques are applied to RGB images and results obtained are analysed for changes to exist or not. Furthermore RGB images obtained after classification when converted to any of the two color models YCbCr and YIQ is found to produce the same results as that of the RGB model images. Thus it can be concluded that other color models like YCbCr, YIQ can be used as substitution to RGB color model for analysing change detection with regard to water pollution.
Results from the MACHO Galactic Pixel Lensing Search
NASA Astrophysics Data System (ADS)
Drake, Andrew J.; Minniti, Dante; Alcock, Charles; Allsman, Robyn A.; Alves, David; Axelrod, Tim S.; Becker, Andrew C.; Bennett, David; Cook, Kem H.; Freeman, Ken C.; Griest, Kim; Lehner, Matt; Marshall, Stuart; Peterson, Bruce; Pratt, Mark; Quinn, Peter; Rodgers, Alex; Stubbs, Chris; Sutherland, Will; Tomaney, Austin; Vandehei, Thor; Welch, Doug L.
The MACHO, EROS, OGLE and AGAPE collaborations have been studying nature of the galactic halo for a number of years using microlensing events. The MACHO group undertakes observations of the LMC, SMC and Galactic Bulge monitoring the light curves of millions of stars to detect microlensing. Most of these fields are crowded to the extent that all the monitored stars are blended. Such crowding makes the performance of accurate photometry difficult. We apply the new technique of Difference Image Analysis (DIA) on archival data to improve the photometry and increase both the detection sensitivity and effective search area. The application of this technique also allows us to detect so called `pixel lensing' events. These are microlensing events where the source star is only detectable during lensing. The detection of these events will allow us to make a large increase in the number of detected microlensing events. We present a light curve demonstrating the detection of a pixel lensing event with this technique.
Farley, Carlton; Kassu, Aschalew; Bose, Nayana; Jackson-Davis, Armitra; Boateng, Judith; Ruffin, Paul; Sharma, Anup
2017-06-01
A short distance standoff Raman technique is demonstrated for detecting economically motivated adulteration (EMA) in extra virgin olive oil (EVOO). Using a portable Raman spectrometer operating with a 785 nm laser and a 2-in. refracting telescope, adulteration of olive oil with grapeseed oil and canola oil is detected between 1% and 100% at a minimum concentration of 2.5% from a distance of 15 cm and at a minimum concentration of 5% from a distance of 1 m. The technique involves correlating the intensity ratios of prominent Raman bands of edible oils at 1254, 1657, and 1441 cm -1 to the degree of adulteration. As a novel variation in the data analysis technique, integrated intensities over a spectral range of 100 cm -1 around the Raman line were used, making it possible to increase the sensitivity of the technique. The technique is demonstrated by detecting adulteration of EVOO with grapeseed and canola oils at 0-100%. Due to the potential of this technique for making measurements from a convenient distance, the short distance standoff Raman technique has the promise to be used for routine applications in food industry such as identifying food items and monitoring EMA at various checkpoints in the food supply chain and storage facilities.
Lima, Victor Fernando Santana; Cringoli, Giuseppe; Rinaldi, Laura; Monteiro, Maria Fernanda Melo; Calado, Andréa Maria Campos; Ramos, Rafael Antonio Nascimento; Meira-Santos, Patrícia Oliveira; Alves, Leucio Câmara
2015-09-01
Dogs may be affected by different species of gastrointestinal parasites which present great importance in veterinary medicine and public health. Several techniques to diagnosing these parasites have been proposed, but different performances achieved by each method make difficult the choice of the best technique to be used. In this study, the performance of two classic methods (i.e., Willis and Hoffman techniques) and two recent techniques (i.e., FLOTAC and Mini-FLOTAC) to diagnosing gastrointestinal parasites of dogs was evaluated. Fecal samples (n = 127) of dogs divided in pools (n = 30) were collected and analyzed using four different techniques (see above). Eggs and/or oocysts of gastrointestinal parasites were detected in 93.3 % (28/30) of the samples. In particular, 20 % (6/30) were detected through the method of Hoffman, 53.3 % (16/30) by the Willis technique, and 63.3 % (19/30) and 90 % (27/30) by Mini-FLOTAC and FLOTAC, respectively. Ancylostomatidae, Trichuris vulpis and Toxocara canis were the most frequent parasites herein detected. The FLOTAC and Mini-FLOTAC techniques were the most efficient tools to detect eggs and/or oocysts of gastrointestinal parasites of dogs, therefore their use is recommended in the laboratorial routine of veterinary medicine. This study is the first report of the use of both techniques (i.e., FLOTAC and Mini-FLOTAC) to diagnosing parasites of dogs in Brazil.
A leakage-free resonance sparse decomposition technique for bearing fault detection in gearboxes
NASA Astrophysics Data System (ADS)
Osman, Shazali; Wang, Wilson
2018-03-01
Most of rotating machinery deficiencies are related to defects in rolling element bearings. Reliable bearing fault detection still remains a challenging task, especially for bearings in gearboxes as bearing-defect-related features are nonstationary and modulated by gear mesh vibration. A new leakage-free resonance sparse decomposition (LRSD) technique is proposed in this paper for early bearing fault detection of gearboxes. In the proposed LRSD technique, a leakage-free filter is suggested to remove strong gear mesh and shaft running signatures. A kurtosis and cosine distance measure is suggested to select appropriate redundancy r and quality factor Q. The signal residual is processed by signal sparse decomposition for highpass and lowpass resonance analysis to extract representative features for bearing fault detection. The effectiveness of the proposed technique is verified by a succession of experimental tests corresponding to different gearbox and bearing conditions.
Biosensor-based microRNA detection: techniques, design, performance, and challenges.
Johnson, Blake N; Mutharasan, Raj
2014-04-07
The current state of biosensor-based techniques for amplification-free microRNA (miRNA) detection is critically reviewed. Comparison with non-sensor and amplification-based molecular techniques (MTs), such as polymerase-based methods, is made in terms of transduction mechanism, associated protocol, and sensitivity. Challenges associated with miRNA hybridization thermodynamics which affect assay selectivity and amplification bias are briefly discussed. Electrochemical, electromechanical, and optical classes of miRNA biosensors are reviewed in terms of transduction mechanism, limit of detection (LOD), time-to-results (TTR), multiplexing potential, and measurement robustness. Current trends suggest that biosensor-based techniques (BTs) for miRNA assay will complement MTs due to the advantages of amplification-free detection, LOD being femtomolar (fM)-attomolar (aM), short TTR, multiplexing capability, and minimal sample preparation requirement. Areas of future importance in miRNA BT development are presented which include focus on achieving high measurement confidence and multiplexing capabilities.
Counterflow Dielectrophoresis for Trypanosome Enrichment and Detection in Blood
NASA Astrophysics Data System (ADS)
Menachery, Anoop; Kremer, Clemens; Wong, Pui E.; Carlsson, Allan; Neale, Steven L.; Barrett, Michael P.; Cooper, Jonathan M.
2012-10-01
Human African trypanosomiasis or sleeping sickness is a deadly disease endemic in sub-Saharan Africa, caused by single-celled protozoan parasites. Although it has been targeted for elimination by 2020, this will only be realized if diagnosis can be improved to enable identification and treatment of afflicted patients. Existing techniques of detection are restricted by their limited field-applicability, sensitivity and capacity for automation. Microfluidic-based technologies offer the potential for highly sensitive automated devices that could achieve detection at the lowest levels of parasitemia and consequently help in the elimination programme. In this work we implement an electrokinetic technique for the separation of trypanosomes from both mouse and human blood. This technique utilises differences in polarisability between the blood cells and trypanosomes to achieve separation through opposed bi-directional movement (cell counterflow). We combine this enrichment technique with an automated image analysis detection algorithm, negating the need for a human operator.
The Applications of Gold Nanoparticle-Initialed Chemiluminescence in Biomedical Detection
NASA Astrophysics Data System (ADS)
Liu, Zezhong; Zhao, Furong; Gao, Shandian; Shao, Junjun; Chang, Huiyun
2016-10-01
Chemiluminescence technique as a novel detection method has gained much attention in recent years owning to the merits of high sensitivity, wider linear ranges, and low background signal. Similarly, nanotechnology especially for gold nanoparticles has emerged as detection tools due to their unique physical and chemical properties. Recently, it has become increasingly popular to couple gold nanoparticles with chemiluminescence technique in biological agents' detection. In this review, we describe the superiority of both chemiluminescence and gold nanoparticles and conclude the different applications of gold nanoparticle-initialed chemiluminescence in biomedical detection.
Beljaars, P R; Van Dijk, R; Jonker, K M; Schout, L J
1998-01-01
An interlaboratory study of the liquid chromatographic (LC) determination of histamine in fish, sauerkraut, and wine was conducted. Diminuted and homogenized samples were suspended in water followed by clarification of extracts with perchloric acid, filtration, and dilution with water. After LC separation on a reversed-phase C18 column with phosphate buffer (pH 3.0)--acetonitrile (875 + 125, v/v) as mobile phase, histamine was measured fluorometrically (excitation, 340 nm; emission, 455 nm) in samples and standards after postcolumn derivatization with o-phthaldialdehyde (OPA). Fourteen samples (including 6 blind duplicates and 1 split level) containing histamine at about 10-400 mg/kg or mg/L were analyzed singly according to the proposed procedure by 11 laboratories. Results from one participant were excluded from statistical analysis. For all samples analyzed, repeatability relative standard deviations varied from 2.1 to 5.6%, and reproducibility relative standard deviations ranged from 2.2 to 7.1%. Averaged recoveries of histamine for this concentration range varied from 94 to 100%.
Catarino, Ana I; Cabral, Henrique N; Peeters, Kris; Pernet, Philippe; Punjabi, Usha; Dubois, Philippe
2008-07-01
The present study evaluated the effects of field metal contamination on sperm motility and the RNA/DNA ratio in echinoderms. Populations of Asterias rubens and Echinus acutus that occur naturally along a contamination gradient of sediments by cadmium, copper, lead, and zinc in a Norwegian fjord (the Sørfjord) were studied. Sperm motility, a measure of sperm quality, was quantified using a computer-assisted sperm analysis system. The RNA/DNA ratio, a measure of protein synthesis, was assessed by a one-dye (ethidium bromide)/one-enzyme (RNase), 96-well microplate fluorometric assay. Although both species accumulate metals at high concentrations, neither sperm motility parameters in A. rubens nor the RNA/DNA ratio in both species were affected. The Sørfjord is still one of the most metal-contaminated marine sites in Europe, but even so, populations of A. rubens and E. acutus are able to endure under these conditions.
Water stress assessment of cork oak leaves and maritime pine needles based on LIF spectra
NASA Astrophysics Data System (ADS)
Lavrov, A.; Utkin, A. B.; Marques da Silva, J.; Vilar, Rui; Santos, N. M.; Alves, B.
2012-02-01
The aim of the present work was to develop a method for the remote assessment of the impact of fire and drought stress on Mediterranean forest species such as the cork oak ( Quercus suber) and maritime pine ( Pinus pinaster). The proposed method is based on laser induced fluorescence (LIF): chlorophyll fluorescence is remotely excited by frequency-doubled YAG:Nd laser radiation pulses and collected and analyzed using a telescope and a gated high sensitivity spectrometer. The plant health criterion used is based on the I 685/ I 740 ratio value, calculated from the fluorescence spectra. The method was benchmarked by comparing the results achieved with those obtained by conventional, continuous excitation fluorometric method and water loss gravimetric measurements. The results obtained with both methods show a strong correlation between them and with the weight-loss measurements, showing that the proposed method is suitable for fire and drought impact assessment on these two species.
NASA Astrophysics Data System (ADS)
Graevskaya, E. E.; Antal, T. K.; Matorin, D. N.; Voronova, E. N.; Pogosyan, S. I.; Rubin, A. B.
2003-05-01
Measurement of chlorophyll fluorescence has been shown to be a rapid, non-invasive, and reliable method to assess photosynthetic performance in a changing environment. In our study, the pulseamplitude-modulation (PAM) - fluorometric method was used to evaluate the sensitivity to chloride mercury and methylmercury chloride of diatomea microalgae Thalassiosira weissflogii. We found that 10^{-6} and 10^{-7} M MeHg led to a slow decrease in the PS II activity following for prolonged lag phase, whereas the algae was not sensitive to the same concentrations of HgCl2. However observed PS II inactivation by methylmercury was not complete and about 10 percents ofthe cells kept the high level of PS II activity as it was shown by microfluorometric analysis. These cells could determine adaptation of algae to methylmercury effect. Both toxicants decreased the rate of PS II reparation, as well as increased a heat pathway of excitation dissipation in PS II antennae complex.