DOE Office of Scientific and Technical Information (OSTI.GOV)
Houston, J. Graeme; Anderson, David; Mills, John
2000-03-15
Purpose: To assess the technical success and early outcome of fluoroscopically guided transcervical fallopian tube recanalization (FTR) in mid-tubal occlusion following sterilization reversal surgery.Methods: From July 1995 to January 1998, patients with greater than 12 months secondary infertility underwent hysterosalpingography (HSG). FTR was performed in proximal or mid-tubal occlusion. Cases of FTR in mid-tubal occlusion were included in this study. Technical success (defined as complete tubal patency) using a standard guidewire and hydrophilic glidewire, the number of patients with at least one patent tube, and the intrauterine and ectopic pregnancy rates were determined.Results: Twenty-six infertile patients with previous sterilization reversalmore » underwent HSG. Eight of 26 (31%) patients (mean age 32 years, range 23-37 years), had attempted FTR for mid-tubal occlusion at the site of surgical anastomosis. Fourteen tubes were attempted as there were two previous salpingectomies. Technical success was achieved in eight of 14 (57%) tubes attempted, resulting in five of eight (62%) patients having at least one patent tube. At follow-up (mean 18 months, range 12-28 months) in these five patients there was one intrauterine pregnancy. There were no ectopic pregnancies.Conclusions: FTR in mid-tubal obstruction in infertile patients following sterilization reversal surgery is technically feasible and may result in intrauterine pregnancy. In this small group there was a lower technical success rate and lower pregnancy rate than in unselected proximal tubal occlusion.« less
Fallopian Tube Catheterization
Thurmond, Amy Suzanne
2013-01-01
Fallopian tube catheterization is used for treatment of infertility caused by proximal tubal occlusion, and has replaced surgical treatment for this condition. More recently, fallopian tube catheterization has been used for tubal sterilization. Interventional radiologists tested numerous methods for tubal occlusion using the rabbit as an animal model. As a result, a tubal device has recently been Food and Drug Administration approved for permanent sterilization using hysteroscopic guidance; it can also be placed fluoroscopically by fallopian tube catheterization as an “off-label” procedure. This is a 5-year continuation and update on a procedure that has been done by interventional radiologists for 25 years; history of the development of fallopian tube catheterization in women has been published in detail in this journal. Highlighted in this article will be description of the basic components needed for fallopian tube catheterization. PMID:24436565
DOE Office of Scientific and Technical Information (OSTI.GOV)
Houston, J. Graeme; Machan, Lindsay S.
1998-01-15
Purpose: To evaluate the technical success and outcome of fallopian tube recanalization (FTR) in salpingitis isthmica nodosa (SIN). Methods: SIN is a well-recognized pathological condition affecting the proximal fallopian tube and is associated with infertility and ectopic pregnancy. We reviewed the presentations, films, and case records of all patients attending for FTR for infertility from 1990 to 1994. Technical success and total, intrauterine, and ectopic pregnancy rates at follow-up were determined. Results: SIN was observed in 22 of 349 (6%) patients. FTR was attempted in 34 tubes in these 22 patients. Technical success was achieved in 23 of 34 (68%)more » tubes affected by SIN. In 5 of the 11 failed recanalizations, failure was due to distal obstruction. At least one tube was patent on selective postprocedural salpingography in 17 of 22 (77%) patients. There were no recorded perforations or complications. At follow-up (mean 14 months), total, intrauterine, and ectopic pregnancy rates were 23%, 18%, and 4.5%, respectively. Conclusion: FTR in SIN is technically successful and, compared with previously reported results in unselected infertility patients, is associated with only a slightly less favorable intrauterine pregnancy rate and a comparable ectopic pregnancy rate. The findings of SIN at FTR should not discourage attempted fluoroscopic transcervical recanalization.« less
The MEPUC concept adapts the C-arm fluoroscope to image-guided surgery.
Suhm, Norbert; Müller, Paul; Bopp, Urs; Messmer, Peter; Regazzoni, Pietro
2004-06-01
Image-guided surgery requires surgeons to be able to manipulate the imaging modality themselves and without delay. Intraoperative fluoroscopic imaging does not meet this requirement as the C-arm fluoroscope cannot be operated or positioned by the surgeons themselves. The Motorized Exact Positioning Unit for C-arm (MEPUC) concept aims to optimize the workflow of positioning the C-arm fluoroscope. The hardware component of the MEPUC equips the fluoroscope with electric stepping motors. The software component allows the surgeon to control the fluoroscope's movements. The study presented here showed that translational movements within the x-y plane are most frequently performed when positioning the C-arm fluoroscope. Furthermore, reproducing a former projection was found to be a frequent task during image-guided procedures. In our opinion, the MEPUC concept adapts the fluoroscope to image-guided surgery. The most important improvement being definition of a bidirectional data exchange between the surgeon and the C-arm fluoroscope: positioning data from the surgeon to the C-arm fluoroscope and-subsequently-image information from C-arm fluoroscope to the surgeon.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee, Woong Hee; Kim, Jin Hyoung, E-mail: m1fenew@daum.net; Park, Jung-Hun
Purpose: Little was known about the safety and long-term efficacy of fluoroscopically guided balloon dilation for postintubation tracheal stenosis. The purpose of this study was to evaluate the safety and long-term efficacy of fluoroscopically guided balloon dilation in patients with postintubation tracheal stenosis. Methods: From February 2000 to November 2010, 14 patients underwent fluoroscopically guided balloon dilation for postintubation tracheal stenosis. Technical success, clinical success, and complications were evaluated. Patients were followed up for recurrent symptoms. Results: In all patients, fluoroscopically guided balloon dilation was technically and clinically successful with no major complications. Following the initial procedure, six patients (43more » %) remained asymptomatic during a follow-up period. Obstructive symptoms recurred in eight patients (57 %) within 6 months (mean, 1.7 months), who were treated with repeat balloon dilation (n = 4) and other therapies. Of the four patients who underwent repeat balloon dilation, three became asymptomatic. One patient became asymptomatic after a third balloon dilation. On long-term (mean, 74 months) follow-up, 71 % of patients experienced relief of symptoms following fluoroscopically guided balloon dilation. Conclusions: Fluoroscopically guided balloon dilation may be safe, is easy to perform, and resulted in effective treatment in patients with postintubation tracheal stenosis.« less
Rusu, M C; Motoc, A G M; Pop, F; Folescu, R
2013-01-01
Five samples of human midterm fetal uterus and fallopian tube (four donor bodies) were used to assess whether or not processes of angiogenesis are guided by endothelial tip cells (ETCs), and if cytokine-receptors, such as CD117/c-kit and PDGFR-α, are expressed in the microenvironment of the endothelial tubes. CD34 labeled microvessels in the uterine wall (myometrium and endometrium) and in the wall of the uterine (fallopian) tube, and accurately identified ETCs in both organs. We conclude that sprouting angiogenesis in the developing human female tract is guided by ETCs. Moreover, CD117/c-kit antibodies labeled mural networks of pericytes, α-SMA-positive and desmin-negative, related to the endometrial (but not myometrial) microvessels, and similar labeling was identified in the wall of the uterine tube. PDGFR-α positive labeling, stromal and pericytary, was also found. Thus, sprouting angiogenesis in human fetal genital organs appears to be guided by tip cells and is influenced by tyrosine kinase receptor signaling.
Fluoroscopic image-guided intervention system for transbronchial localization
NASA Astrophysics Data System (ADS)
Rai, Lav; Keast, Thomas M.; Wibowo, Henky; Yu, Kun-Chang; Draper, Jeffrey W.; Gibbs, Jason D.
2012-02-01
Reliable transbronchial access of peripheral lung lesions is desirable for the diagnosis and potential treatment of lung cancer. This procedure can be difficult, however, because accessory devices (e.g., needle or forceps) cannot be reliably localized while deployed. We present a fluoroscopic image-guided intervention (IGI) system for tracking such bronchoscopic accessories. Fluoroscopy, an imaging technology currently utilized by many bronchoscopists, has a fundamental shortcoming - many lung lesions are invisible in its images. Our IGI system aligns a digitally reconstructed radiograph (DRR) defined from a pre-operative computed tomography (CT) scan with live fluoroscopic images. Radiopaque accessory devices are readily apparent in fluoroscopic video, while lesions lacking a fluoroscopic signature but identifiable in the CT scan are superimposed in the scene. The IGI system processing steps consist of: (1) calibrating the fluoroscopic imaging system; (2) registering the CT anatomy with its depiction in the fluoroscopic scene; (3) optical tracking to continually update the DRR and target positions as the fluoroscope is moved about the patient. The end result is a continuous correlation of the DRR and projected targets with the anatomy depicted in the live fluoroscopic video feed. Because both targets and bronchoscopic devices are readily apparent in arbitrary fluoroscopic orientations, multiplane guidance is straightforward. The system tracks in real-time with no computational lag. We have measured a mean projected tracking accuracy of 1.0 mm in a phantom and present results from an in vivo animal study.
Yuenyongviwat, Varah; Tuntarattanapong, Pakjai; Tangtrakulwanich, Boonsin
2016-01-11
Internal fixation is one treatment for femoral neck fracture. Some devices and techniques reported improved accuracy and decreased fluoroscopic time. However, these are not widely used nowadays due to the lack of available special instruments and techniques. To improve the surgical procedure, the authors designed a new adjustable drill guide and tested the efficacy of the device. The authors developed a new adjustable drill guide for cannulated screw guide wire insertion for multiple screw fixation. Eight orthopaedic surgeons performed the experimental study to evaluate the efficacy of this device. Each surgeon performed guide wire insertion for multiple screw fixation in six synthetic femurs: three times with the new device and three times with the conventional technique. The fluoroscopic time, operative time and surgeon satisfaction were evaluated. In the operations with the new adjustable drill guide, the fluoroscopic and operative times were significantly lower than the operations with the conventional technique (p < 0.05). The mean score for the level of satisfaction of this device was also statistically significantly better (p = 0.02) than the conventional technique. The fluoroscopic and operative times with the new adjustable drill guide were reduced for multiple screw fixation of femoral neck fracture and the satisfaction of the surgeons was good.
Kwon, Young Ho; Kwon, Se Hwan; Oh, Joo Hyeong; Jeong, Kyung Hwan; Lee, Tae Won
2014-06-01
To assess the efficacy of fluoroscopic guide wire manipulation in patients with malfunctioning peritoneal dialysis (PD) catheters that were initially placed by interventional radiologists under fluoroscopic guidance. From January 2002 to April 2012, 52 patients (mean age, 52.8 y ± 2.10s; range, 12-79 y) with malfunctioning PD catheters in whom fluoroscopic guide wire manipulation was performed were retrospectively reviewed. Technical success, clinical success, and complications were evaluated. Technical success was defined as fluoroscopically verified, successful catheter repositioning and adequate dialysate drainage after the procedure. Clinical success was defined as maintenance of PD catheter function for at least 30 days after the manipulation. During the study period, 72 manipulations (68 initial manipulations and 4 remanipulations) for malfunctioning PD catheters were done. The technical success rate was 74% (50 of 68) for initial manipulations and 75% (3 of 4) for remanipulations. The overall clinical success rate was 47% (32 of 68) for initial manipulations and 0% (0 of 4) for remanipulations. The primary causes of catheter malfunction were extraluminal obstruction by omental wrapping or adhesions in 43 of 68 cases (63.2%) and catheter malposition in 25 of 68 (36.8%) cases. There were no procedure-related major complications. Fluoroscopic guide wire manipulation in patients with malfunctioning PD catheters initially placed by interventional radiologists is a simple procedure, an effective way of prolonging PD catheter life, and a recommended procedure before invasive surgical procedures. Copyright © 2014 SIR. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Mefleh, Fuad N.; Baker, G. Hamilton; Kwartowitz, David M.
2014-03-01
In our previous work we presented a novel image-guided surgery (IGS) system, Kit for Navigation by Image Focused Exploration (KNIFE).1,2 KNIFE has been demonstrated to be effective in guiding mock clinical procedures with the tip of an electromagnetically tracked catheter overlaid onto a pre-captured bi-plane fluoroscopic loop. Representation of the catheter in KNIFE differs greatly from what is captured by the fluoroscope, due to distortions and other properties of fluoroscopic images. When imaged by a fluoroscope, catheters can be visualized due to the inclusion of radiopaque materials (i.e. Bi, Ba, W) in the polymer blend.3 However, in KNIFE catheter location is determined using a single tracking seed located in the catheter tip that is represented as a single point overlaid on pre-captured fluoroscopic images. To bridge the gap in catheter representation between KNIFE and traditional methods we constructed a catheter with five tracking seeds positioned along the distal 70 mm of the catheter. We have currently investigated the use of four spline interpolation methods for estimation of true catheter shape and have assesed the error in their estimation of true catheter shape. In this work we present a method for the evaluation of interpolation algorithms with respect to catheter shape determination.
Rutten, Matthieu J C M; Collins, James M P; Maresch, Bas J; Smeets, Jacques H J M; Janssen, Caroline M M; Kiemeney, Lambertus A L M; Jager, Gerrit J
2009-03-01
To assess the variability in accuracy of contrast media introduction, leakage, required time and patient discomfort in four different centres, each using a different image-guided glenohumeral injection technique. Each centre included 25 consecutive patients. The ultrasound-guided anterior (USa) and posterior approach (USp), fluoroscopic-guided anterior (FLa) and posterior (FLp) approach were used. Number of injection attempts, effect of contrast leakage on diagnostic quality, and total room, radiologist and procedure times were measured. Pain was documented with a visual analogue scale (VAS) pain score. Access to the joint was achieved in all patients. A successful first attempt significantly occurred more often with US (94%) than with fluoroscopic guidance (72%). Leakage of contrast medium did not cause interpretative difficulties. With US guidance mean room, procedure and radiologist times were significantly shorter (p < 0.001). The USa approach was rated with the lowest pre- and post-injection VAS scores. The four image-guided injection techniques are successful in injection of contrast material into the glenohumeral joint. US-guided injections and especially the anterior approach are significantly less time consuming, more successful on the first attempt, cause less patient discomfort and obviate the need for radiation and iodine contrast.
Ultrasound-guided lumbar puncture in pediatric patients: technical success and safety.
Pierce, David B; Shivaram, Giri; Koo, Kevin S H; Shaw, Dennis W W; Meyer, Kirby F; Monroe, Eric J
2018-06-01
Disadvantages of fluoroscopically guided lumbar puncture include delivery of ionizing radiation and limited resolution of incompletely ossified posterior elements. Ultrasound (US) allows visualization of critical soft tissues and the cerebrospinal fluid (CSF) space without ionizing radiation. To determine the technical success and safety of US-guided lumbar puncture in pediatric patients. A retrospective review identified all patients referred to interventional radiology for lumbar puncture between June 2010 and June 2017. Patients who underwent lumbar puncture with fluoroscopic guidance alone were excluded. For the remaining procedures, technical success and procedural complications were assessed. Two hundred and one image-guided lumbar punctures in 161 patients were included. Eighty patients (43%) had previously failed landmark-based attempts. One hundred ninety-six (97.5%) patients underwent lumbar puncture. Five procedures (2.5%) were not attempted after US assessment, either due to a paucity of CSF or unsafe window for needle placement. Technical success was achieved in 187 (95.4%) of lumbar punctures attempted with US guidance. One hundred seventy-seven (90.3%) were technically successful with US alone (age range: 2 days-15 years, weight range: 1.9-53.1 kg) and an additional 10 (5.1%) were successful with US-guided thecal access and subsequent fluoroscopic confirmation. Three (1.5%) cases were unsuccessful with US guidance but were subsequently successful with fluoroscopic guidance. Of the 80 previously failed landmark-based lumbar punctures, 77 (96.3%) were successful with US guidance alone. There were no reported complications. US guidance is safe and effective for lumbar punctures and has specific advantages over fluoroscopy in pediatric patients.
Fluoroscopic tumor tracking for image-guided lung cancer radiotherapy
NASA Astrophysics Data System (ADS)
Lin, Tong; Cerviño, Laura I.; Tang, Xiaoli; Vasconcelos, Nuno; Jiang, Steve B.
2009-02-01
Accurate lung tumor tracking in real time is a keystone to image-guided radiotherapy of lung cancers. Existing lung tumor tracking approaches can be roughly grouped into three categories: (1) deriving tumor position from external surrogates; (2) tracking implanted fiducial markers fluoroscopically or electromagnetically; (3) fluoroscopically tracking lung tumor without implanted fiducial markers. The first approach suffers from insufficient accuracy, while the second may not be widely accepted due to the risk of pneumothorax. Previous studies in fluoroscopic markerless tracking are mainly based on template matching methods, which may fail when the tumor boundary is unclear in fluoroscopic images. In this paper we propose a novel markerless tumor tracking algorithm, which employs the correlation between the tumor position and surrogate anatomic features in the image. The positions of the surrogate features are not directly tracked; instead, we use principal component analysis of regions of interest containing them to obtain parametric representations of their motion patterns. Then, the tumor position can be predicted from the parametric representations of surrogates through regression. Four regression methods were tested in this study: linear and two-degree polynomial regression, artificial neural network (ANN) and support vector machine (SVM). The experimental results based on fluoroscopic sequences of ten lung cancer patients demonstrate a mean tracking error of 2.1 pixels and a maximum error at a 95% confidence level of 4.6 pixels (pixel size is about 0.5 mm) for the proposed tracking algorithm.
Kelekis, Alexios; Filippiadis, Dimitrios K; Velonakis, Georgios; Martin, Jean-Baptist; Oikonomopoulos, Nikolaos; Brountzos, Elias; Kelekis, Nikolaos
2014-01-01
Transforaminal infiltrations in the cervical spine are governed by a higher rate of vascular puncture than in the lumbar spine. The purpose of our study is to assess the safety and efficacy of percutaneous, fluoroscopically guided nerve root infiltrations in cases of cervical radiculopathy. An indirect postero-lateral approach was performed through the ipsilateral facet joint. During the last 2 years, 25 patients experiencing cervical radiculopathy underwent percutaneous, fluoroscopically guided nerve root infiltrations by means of an indirect postero-lateral approach through the ipsilateral facet joint. The intra-articular position of the needle (22-gauge spinal needle) was fluoroscopically verified after injection of a small amount of contrast medium which also verified dispersion of the contrast medium periradicularly and in the epidural space. Then a mixture of long-acting glucocorticosteroid diluted in normal saline (1.5/1 mL) was injected intra-articularly. A questionnaire with a Numeric Visual Scale (NVS) scale helped assess pain relief, life quality, and mobility improvement. A mean of 2.3 sessions was performed in the patients of our study. In the vast majority of our patients 19/25 (76%), the second infiltration was performed within 7-10 days of the first one. Comparing the pain scores prior (mean value 8.80 ± 1.080 NVS units) and after (mean value 1.84 ± 1.405 NVS units), there was a mean decrease of 6.96 ± 1.695 NVS units [median value 7 NVS units (P < 0.001) in terms of pain reduction, effect upon mobility, and life quality. There were no clinically significant complications noted in our study. Fluoroscopically guided transforaminal infiltrations through the ipsilateral facet joint seem to be a feasible, efficacious, and safe approach for the treatment of patients with cervical radiculopathy. This approach facilitates needle placement and minimizes risk of complications.
Fluoroscopically Guided Peritendinous Corticosteroid Injection for Proximal Hamstring Tendinopathy
Nicholson, Luke T.; DiSegna, Steven; Newman, Joel S.; Miller, Suzanne L.
2014-01-01
Background: Proximal hamstring tendinopathy is an uncommon but debilitating cause of posterior thigh pain in athletes subjected to repetitive eccentric hamstring contraction, such as runners. Minimal data exist evaluating treatment options for proximal hamstring tendinopathy. Purpose: This retrospective study evaluates the effectiveness of fluoroscopically guided corticosteroid injections in treating proximal hamstring tendinopathy. Study Design: Case series; Level of evidence, 4. Methods: Eighteen athletes with 22 cases of magnetic resonance imaging–confirmed proximal hamstring tendinopathy were treated with corticosteroid injection and later contacted to evaluate the efficacy of the injection with the use of a questionnaire. Results: The visual analog score decreased from 7.22 preinjection to 3.94 postinjection (P < .001), level of athletic participation increased from 28.76% to 68.82% (P < .001) at a mean follow-up of 21 months, and 38.8% of patients experienced complete resolution at a mean follow-up of 24.8 months. The mean lower extremity function score at the time of follow-up was 60. Conclusion: A trial of fluoroscopically guided corticosteroid injection is warranted in patients presenting with symptoms of proximal hamstring tendinopathy refractory to conservative therapy. PMID:26535310
Nicholson, Luke T; DiSegna, Steven; Newman, Joel S; Miller, Suzanne L
2014-03-01
Proximal hamstring tendinopathy is an uncommon but debilitating cause of posterior thigh pain in athletes subjected to repetitive eccentric hamstring contraction, such as runners. Minimal data exist evaluating treatment options for proximal hamstring tendinopathy. This retrospective study evaluates the effectiveness of fluoroscopically guided corticosteroid injections in treating proximal hamstring tendinopathy. Case series; Level of evidence, 4. Eighteen athletes with 22 cases of magnetic resonance imaging-confirmed proximal hamstring tendinopathy were treated with corticosteroid injection and later contacted to evaluate the efficacy of the injection with the use of a questionnaire. The visual analog score decreased from 7.22 preinjection to 3.94 postinjection (P < .001), level of athletic participation increased from 28.76% to 68.82% (P < .001) at a mean follow-up of 21 months, and 38.8% of patients experienced complete resolution at a mean follow-up of 24.8 months. The mean lower extremity function score at the time of follow-up was 60. A trial of fluoroscopically guided corticosteroid injection is warranted in patients presenting with symptoms of proximal hamstring tendinopathy refractory to conservative therapy.
Percutaneous Relief of Tension Pneumomediastinum in a Child
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chau, Helen Hoi-lun; Kwok, Philip Chong-hei; Lai, Albert Kwok-hung
2003-11-15
The purpose of this article was to describe the experience of relieving tension pneumomediastinum by a fluoroscopic-guided percutaneous method. We inserted a percutaneous drainage catheter with a Heimlich valve under fluoroscopic guidance to relieve the tension pneumomediastinum in a 2-year-old girl who suffered from dermatomyositis with lung involvement. This allowed immediate relief without the need for surgery. The procedure was repeated for relapsed tension pneumomediastinum. Good immediate results were achieved in each attempt. We conclude that percutaneous relief of pneumomediastinum under fluoroscopic guidance can be performed safely and rapidly in patients not fit for surgery.
Manchikanti, Laxmaiah; Cash, Kim A; Pampati, Vidyasagar; Damron, Kim S; McManus, Carla D
2004-04-01
Transforaminal epidural steroid injection is one of the commonly employed modalities of treatment in managing nerve root pain. However, there have been no controlled prospective evaluations of epidural and nerve root contrast distribution patterns and other aspects of fluoroscopically directed lumbosacral transforaminal epidural steroid injections. To evaluate contrast flow patterns and intravascular needle placement of fluoroscopically guided lumbosacral transforaminal epidural injections. A prospective, observational study. A total of 100 consecutive patients undergoing fluoroscopically guided transforaminal epidural steroid injections were evaluated. The contrast flow patterns, ventral or dorsal epidural filling, nerve root filling, C-arm time, and intravascular needle placement were evaluated. Ventral epidural filling was seen in 88% of the procedures, in contrast to dorsal filling noted in 9% of the procedures. Nerve root filling was seen in 97% of the procedures. Total intravenous placement of the needle was noted in 22% of the procedures, whereas negative flashback and aspiration was noted in 5% of the procedures. Lumbosacral transforaminal epidural injections, performed under fluoroscopic visualization, provide excellent nerve root filling and ventral epidural filling patterns. However, unrecognized intravascular needle placement with negative flashback or aspiration was noted in 5% of the procedures.
Usawachintachit, Manint; Masic, Selma; Allen, Isabel E.; Li, Jianxing
2016-01-01
Abstract Objectives: To define the learning curve associated with adopting ultrasound guidance for prone percutaneous nephrolithotomy (PCNL) for the experienced surgeon. Methods: A prospective cohort study of consecutive patients undergoing PCNL with ultrasound guidance for renal tract access and dilation was performed. Clinical data reviewed included success in gaining renal access with ultrasound guidance, total fluoroscopic screening time, and radiation exposure dose. PCNL cases performed with fluoroscopic guidance matched for stone size served as control cases. Results: One hundred consecutive ultrasound-guided procedures performed by a single experienced endourologist were divided into five experience groups. Significant improvement in renal access success rate with ultrasound was seen after 20 cases (p < 0.05). Total fluoroscopic screening time, radiation exposure dose, and operative time were also statistically significantly improved over the study period. When compared with fluoroscopy-guided PCNL, significant decreases in total fluoroscopic screening time (33.4 ± 35.3 seconds vs 157.5 ± 84.9 seconds, p < 0.05) and radiation exposure (7.0 ± 8.7 mGy vs 47.8 ± 45.9 mGy, p < 0.05) were seen. No differences in complication rates were found. Conclusions: Ultrasound-guided renal access for PCNL can be performed effectively after 20 cases. Transition to the use of ultrasound will quickly reduce radiation exposure for patients and intraoperative personnel. PMID:27150671
Kim, Honsoul; Kim, Seung Hyoung; Choi, Sun Young; Lee, Kwang-Hun; Won, Jong Yoon; Lee, Do Yun; Lee, Jong Tae
2008-12-01
To evaluate the technical feasibility and clinical effectiveness of fluoroscopically guided placement of self-expandable metallic stents and stent-grafts for acute malignant colorectal obstruction. Radiologic images and clinical reports of 42 patients (22 men, 20 women; age range, 28-93 years; median age, 65.5 years) who underwent fluoroscopically guided colorectal stent insertion without endoscopic assistance for acute malignant obstruction were reviewed retrospectively. Eighteen patients received bare stents as a bridge to surgery. Twenty-four patients received 27 insertions of either a bare stent (n = 15) or a stent-graft (n = 12) for palliation. The obstruction was located in the rectum (n = 8), sigmoid (n = 17), descending colon (n = 8), splenic flexure (n = 3), and transverse colon (n = 6). Clinical success, defined as more than 50% dilatation of the stent with subsequent symptomatic improvement, was achieved in 41 of the 42 patients (98%). No major procedure-related complications occurred. Minor complications occurred in eight of the 45 procedures (18%). No perioperative mortalities occurred within 1 month after surgery. In the palliative group, the median stent patency was 62 days (range, 0-1,014 days). There was no statistically significant difference in stent patency between the bare stents (range, 0-855 days; median, 68 days) and stent-grafts (range, 1-1,014 days; median, 81 days). Fluoroscopically guided placement of self-expandable metallic stents and stent-grafts for the relief of acute malignant colorectal obstruction was technically feasible without endoscopic assistance-even in lesions proximal to the splenic flexure and transverse colon-and clinically effective in both bridge to surgery and palliative management.
Hu, Hong-Tao; Shin, Ji Hoon; Kim, Jin-Hyoung; Jang, Jong Keon; Park, Jung-Hoon; Kim, Tae-Hyung; Nam, Deok Ho; Song, Ho-Young
2015-07-01
We aimed to evaluate the safety and clinical effectiveness of fluoroscopically guided large balloon dilatation for treating congenital esophageal stenosis in children. Our study included seven children (mean age 4.0 years) who underwent a total of ten balloon dilatation sessions. The initial balloon diameters were 10-15 mm. The technical success, clinical success (improved food intake and reduced dysphagia within 1 month following the first balloon dilatation), dysphagia recurrence, and complications were retrospectively evaluated. Technical and clinical success rates were 100 %. During the mean 38-month follow-up period after the first balloon dilatation, 3 (43 %) patients underwent only one additional balloon dilatation 4-5 months after the first balloon dilatation for dysphagia recurrence. Two of them showed improvement without further recurrence, while the remaining one underwent partial esophagectomy. Well-contained transmural esophageal rupture (type 2) occurred in two (29 %, 2/7) patients and during two (20 %, 2/10) balloon dilatation sessions. All ruptures were successfully treated conservatively. Our study showed that fluoroscopically guided large balloon dilatation seems to be a simple and effective primary treatment technique for congenital esophageal stenosis in children. Esophageal ruptures were not uncommon although they were not fatal.
Fluoroscopic Placement of Double-Pigtail Ureteral Stents
Chen, Gregory L.
2001-01-01
Purpose: Double-pigtail ureteral stent is placed cystoscopically after ureteroscopy. We describe a technique for fluoroscopic placement of ureteral stents and demonstrate its use in a non-randomized prospective study. Materials and methods: Double-pigtail stents were placed either fluoroscopically or cystoscopically in 121 consecutive patients. In the fluoroscopic method, the stent was placed over a guide wire using a stent pusher without the use of cystoscopy. Conversely, stents were placed through the working channel of the cystoscope under vision. The procedure, stent length, width, type, method, ureteral dilation, and use of a retrieval string were noted. Results: A wide range of stent sizes were used. The success with fluoroscopic placement of double-pigtail ureteral stents was 100% (89 of 89 cases). No stents migrated or required replacement. Stents were placed after ureteroscopic laser lithotripsy (53/89) and ureteroscopic tumor treatment (22/89). Cystoscopic visualization was used in 32 additional procedures requiring precise control (15 ureteral strictures and nine retrograde endopyelotomy). Conclusions: The fluoroscopic placement of ureteral stents is a safe and simple technique with a very high success rate. We have used cystoscopic placement only after incisional procedures such as retrograde endopyelotomy, stricture or ureterotomy. PMID:18493562
Kennedy, David J; Engel, Andrew; Kreiner, D Scott; Nampiaparampil, Devi; Duszynski, Belinda; MacVicar, John
2015-08-01
To assess the validity of fluoroscopically guided diagnostic intra-articular injections of local anesthetic and effectiveness of intra-articular steroid injections in treating sacroiliac joint (SIJ) pain. Systematic review. Ten reviewers independently assessed 45 publications on diagnostic validity or effectiveness of fluoroscopically guided intra-articular SIJ injections. For diagnostic injections, the primary outcome was validity; for therapeutic injections, analgesia. Secondary outcomes were also described. Of 45 articles reviewed, 39 yielded diagnostic data on physical exam findings, provocation tests, and SIJ injections for diagnosing SIJ pain, and 15 addressed therapeutic effectiveness. When confirmed by comparative local anesthetic blocks with a high degree of pain relief, no single physical exam maneuver predicts response to diagnostic injections. When at least three physical exam findings are present, sensitivity, and specificity increases significantly. The prevalence of SIJ pain is likely 20-30% among patients that have suspected SIJ pain based on history and physical examination. This estimate may be higher in certain subgroups such as the elderly and fusion patients. Two randomized controlled trials and multiple observational studies supported the effectiveness of therapeutic sacroiliac joint injections. Based on this literature, it is unclear whether image-guided intra-articular diagnostic injections of local anesthetic predict positive responses to therapeutic agents. The overall quality of evidence is moderate for the effectiveness of therapeutic SIJ injections. Wiley Periodicals, Inc.
2017-05-03
Anxiety; Fatigue; Nausea and Vomiting; Neurotoxicity Syndrome; Recurrent Fallopian Tube Carcinoma; Recurrent Ovarian Carcinoma; Recurrent Primary Peritoneal Carcinoma; Stage I Ovarian Cancer; Stage IA Fallopian Tube Cancer; Stage IB Fallopian Tube Cancer; Stage IC Fallopian Tube Cancer; Stage II Ovarian Cancer; Stage IIA Fallopian Tube Cancer; Stage IIB Fallopian Tube Cancer; Stage IIC Fallopian Tube Cancer; Stage III Ovarian Cancer; Stage III Primary Peritoneal Cancer; Stage IIIA Fallopian Tube Cancer; Stage IIIB Fallopian Tube Cancer; Stage IIIC Fallopian Tube Cancer; Stage IV Fallopian Tube Cancer; Stage IV Ovarian Cancer; Stage IV Primary Peritoneal Cancer
2017-05-03
Stage I Ovarian Cancer; Stage IA Fallopian Tube Cancer; Stage IB Fallopian Tube Cancer; Stage IC Fallopian Tube Cancer; Stage II Ovarian Cancer; Stage IIA Fallopian Tube Cancer; Stage IIB Fallopian Tube Cancer; Stage IIC Fallopian Tube Cancer; Stage III Ovarian Cancer; Stage III Primary Peritoneal Cancer; Stage IIIA Fallopian Tube Cancer; Stage IIIB Fallopian Tube Cancer; Stage IIIC Fallopian Tube Cancer; Stage IV Fallopian Tube Cancer; Stage IV Ovarian Cancer; Stage IV Primary Peritoneal Cancer
2017-08-21
Borderline Ovarian Mucinous Tumor; Ovarian Mucinous Cystadenocarcinoma; Recurrent Fallopian Tube Carcinoma; Recurrent Ovarian Carcinoma; Stage IA Fallopian Tube Cancer; Stage IA Ovarian Cancer; Stage IB Fallopian Tube Cancer; Stage IB Ovarian Cancer; Stage IC Fallopian Tube Cancer; Stage IC Ovarian Cancer; Stage IIA Fallopian Tube Cancer; Stage IIA Ovarian Cancer; Stage IIB Fallopian Tube Cancer; Stage IIB Ovarian Cancer; Stage IIC Fallopian Tube Cancer; Stage IIC Ovarian Cancer; Stage IIIA Fallopian Tube Cancer; Stage IIIA Ovarian Cancer; Stage IIIB Fallopian Tube Cancer; Stage IIIB Ovarian Cancer; Stage IIIC Fallopian Tube Cancer; Stage IIIC Ovarian Cancer; Stage IV Fallopian Tube Cancer; Stage IV Ovarian Cancer
Scale-space for empty catheter segmentation in PCI fluoroscopic images.
Bacchuwar, Ketan; Cousty, Jean; Vaillant, Régis; Najman, Laurent
2017-07-01
In this article, we present a method for empty guiding catheter segmentation in fluoroscopic X-ray images. The guiding catheter, being a commonly visible landmark, its segmentation is an important and a difficult brick for Percutaneous Coronary Intervention (PCI) procedure modeling. In number of clinical situations, the catheter is empty and appears as a low contrasted structure with two parallel and partially disconnected edges. To segment it, we work on the level-set scale-space of image, the min tree, to extract curve blobs. We then propose a novel structural scale-space, a hierarchy built on these curve blobs. The deep connected component, i.e. the cluster of curve blobs on this hierarchy, that maximizes the likelihood to be an empty catheter is retained as final segmentation. We evaluate the performance of the algorithm on a database of 1250 fluoroscopic images from 6 patients. As a result, we obtain very good qualitative and quantitative segmentation performance, with mean precision and recall of 80.48 and 63.04% respectively. We develop a novel structural scale-space to segment a structured object, the empty catheter, in challenging situations where the information content is very sparse in the images. Fully-automatic empty catheter segmentation in X-ray fluoroscopic images is an important and preliminary step in PCI procedure modeling, as it aids in tagging the arrival and removal location of other interventional tools.
Chiu, Chee Kidd; Chan, Chris Yin Wei; Kwan, Mun Keong
2017-01-01
This study investigates the safety and accuracy of percutaneous pedicle screws placed using fluoroscopic guidance in the thoracolumbosacral spine among Asian patients. Computerized tomography scans of 128 patients who had surgery using fluoroscopic-guided percutaneous pedicle screws were selected. Medial, lateral, superior, and inferior screw perforations were classified into grade 0 (no violation), grade 1 (<2 mm perforation), grade 2 (2-4 mm perforation), and grade 3(>4 mm perforation). Anterior perforations were classified into grade 0 (no violation), grade 1 (<4 mm perforation), grade 2 (4-6 mm perforation), and grade 3(>6 mm perforation). Grade 2 and grade 3 perforation were considered as "critical" perforation. In total, 1002 percutaneous pedicle screws from 128 patients were analyzed. The mean age was 52.7 ± 16.6. There were 70 male patients and 58 female patients. The total perforation rate was 11.3% (113) with 8.4% (84) grade 1, 2.6% (26) grade 2, and 0.3% (3) grade 3 perforations. The overall "critical" perforation rate was 2.9% (29 screws) and no complications were noted. The highest perforation rates were at T4 (21.6%), T2 (19.4%), and T6 (19.2%). The total perforation rate of 11.3% with the total "critical" perforation rate of 2.9% (2.6% grade 2 and 0.3% grade 3 perforations). The highest perforation rates were found over the upper to mid-thoracic region. Fluoroscopic-guided percutaneous pedicle screws insertion among Asians has the safety and accuracy comparable to the current reported percutaneous pedicle screws and open pedicle screws techniques.
2017-05-03
Fallopian Tube Clear Cell Adenocarcinoma; Fallopian Tube Endometrioid Adenocarcinoma; Fallopian Tube Mucinous Adenocarcinoma; Fallopian Tube Serous Adenocarcinoma; Fallopian Tube Transitional Cell Carcinoma; Ovarian Brenner Tumor; Ovarian Clear Cell Adenocarcinoma; Ovarian Endometrioid Adenocarcinoma; Ovarian Mucinous Adenocarcinoma; Ovarian Seromucinous Carcinoma; Ovarian Serous Adenocarcinoma; Ovarian Transitional Cell Carcinoma; Primary Peritoneal Serous Adenocarcinoma; Stage IIIA Fallopian Tube Cancer; Stage IIIA Ovarian Cancer; Stage IIIA Primary Peritoneal Cancer; Stage IIIB Fallopian Tube Cancer; Stage IIIB Ovarian Cancer; Stage IIIB Primary Peritoneal Cancer; Stage IIIC Fallopian Tube Cancer; Stage IIIC Ovarian Cancer; Stage IIIC Primary Peritoneal Cancer; Stage IV Fallopian Tube Cancer; Stage IV Ovarian Cancer; Stage IV Primary Peritoneal Cancer; Undifferentiated Fallopian Tube Carcinoma; Undifferentiated Ovarian Carcinoma
2017-10-12
Fallopian Tube Clear Cell Adenocarcinoma; Fallopian Tube Endometrioid Tumor; Fallopian Tube Mucinous Neoplasm; Fallopian Tube Serous Neoplasm; Fallopian Tube Transitional Cell Carcinoma; Ovarian Clear Cell Cystadenocarcinoma; Ovarian Endometrioid Adenocarcinoma; Ovarian Mucinous Cystadenocarcinoma; Ovarian Seromucinous Carcinoma; Ovarian Serous Cystadenocarcinoma; Ovarian Transitional Cell Carcinoma; Primary Peritoneal Serous Adenocarcinoma; Recurrent Fallopian Tube Carcinoma; Recurrent Ovarian Carcinoma; Recurrent Primary Peritoneal Carcinoma; Stage IIIC Fallopian Tube Cancer; Stage IIIC Ovarian Cancer; Stage IIIC Primary Peritoneal Cancer; Stage IV Fallopian Tube Cancer; Stage IV Ovarian Cancer; Stage IV Primary Peritoneal Cancer; Undifferentiated Fallopian Tube Carcinoma; Undifferentiated Ovarian Carcinoma
Intraoperative fluoroscopic evaluation of screw placement during pelvic and acetabular surgery.
Yi, Chengla; Burns, Sean; Hak, David J
2014-01-01
The surgical treatment of pelvic and acetabular fractures can be technically challenging. Various techniques are available for the reconstruction of pelvic and acetabular fractures. Less invasive percutaneous fracture stabilization techniques, with closed reduction or limited open reduction, have been developed and are gaining popularity in the management of pelvic and acetabular fractures. These techniques require knowledge and interpretation of various fluoroscopic images to ensure appropriate and safe screw placement. Given the anatomic complexity of the intrapelvic structures and the 2-dimensional nature of standard fluoroscopy, multiple images oriented in different planes are needed to assess the accuracy of guide wire and screw placement. This article reviews the fluoroscopic imaging of common screw orientations during pelvic and acetabular surgery.
NASA Astrophysics Data System (ADS)
Kilian-Meneghin, Josh; Xiong, Z.; Rudin, S.; Oines, A.; Bednarek, D. R.
2017-03-01
The purpose of this work is to evaluate methods for producing a library of 2D-radiographic images to be correlated to clinical images obtained during a fluoroscopically-guided procedure for automated patient-model localization. The localization algorithm will be used to improve the accuracy of the skin-dose map superimposed on the 3D patient- model of the real-time Dose-Tracking-System (DTS). For the library, 2D images were generated from CT datasets of the SK-150 anthropomorphic phantom using two methods: Schmid's 3D-visualization tool and Plastimatch's digitally-reconstructed-radiograph (DRR) code. Those images, as well as a standard 2D-radiographic image, were correlated to a 2D-fluoroscopic image of a phantom, which represented the clinical-fluoroscopic image, using the Corr2 function in Matlab. The Corr2 function takes two images and outputs the relative correlation between them, which is fed into the localization algorithm. Higher correlation means better alignment of the 3D patient-model with the patient image. In this instance, it was determined that the localization algorithm will succeed when Corr2 returns a correlation of at least 50%. The 3D-visualization tool images returned 55-80% correlation relative to the fluoroscopic-image, which was comparable to the correlation for the radiograph. The DRR images returned 61-90% correlation, again comparable to the radiograph. Both methods prove to be sufficient for the localization algorithm and can be produced quickly; however, the DRR method produces more accurate grey-levels. Using the DRR code, a library at varying angles can be produced for the localization algorithm.
2018-05-21
Fallopian Tube Adenocarcinoma; Fallopian Tube Clear Cell Adenocarcinoma; Fallopian Tube Endometrioid Adenocarcinoma; Fallopian Tube Mucinous Adenocarcinoma; Fallopian Tube Serous Adenocarcinoma; Fallopian Tube Transitional Cell Carcinoma; Malignant Ovarian Brenner Tumor; Malignant Ovarian Clear Cell Tumor; Malignant Ovarian Endometrioid Tumor; Malignant Ovarian Mixed Epithelial Tumor; Malignant Ovarian Mucinous Tumor; Malignant Ovarian Neoplasm; Malignant Ovarian Serous Tumor; Malignant Ovarian Transitional Cell Tumor; Ovarian Adenocarcinoma; Primary Peritoneal Serous Adenocarcinoma; Stage IIIA Fallopian Tube Cancer; Stage IIIA Ovarian Cancer; Stage IIIA Primary Peritoneal Cancer; Stage IIIB Fallopian Tube Cancer; Stage IIIB Ovarian Cancer; Stage IIIB Primary Peritoneal Cancer; Stage IIIC Fallopian Tube Cancer; Stage IIIC Ovarian Cancer; Stage IIIC Primary Peritoneal Cancer; Stage IV Fallopian Tube Cancer; Stage IV Ovarian Cancer; Stage IV Primary Peritoneal Cancer; Undifferentiated Fallopian Tube Carcinoma; Undifferentiated Ovarian Carcinoma
2017-09-12
Stage IA Fallopian Tube Cancer; Stage IA Ovarian Cancer; Stage IB Fallopian Tube Cancer; Stage IB Ovarian Cancer; Stage IC Fallopian Tube Cancer; Stage IC Ovarian Cancer; Stage IIA Fallopian Tube Cancer; Stage IIA Ovarian Cancer; Stage IIB Fallopian Tube Cancer; Stage IIB Ovarian Cancer; Stage IIC Fallopian Tube Cancer; Stage IIC Ovarian Cancer; Stage IIIA Fallopian Tube Cancer; Stage IIIA Ovarian Cancer; Stage IIIA Primary Peritoneal Cancer; Stage IIIB Fallopian Tube Cancer; Stage IIIB Ovarian Cancer; Stage IIIB Primary Peritoneal Cancer; Stage IIIC Fallopian Tube Cancer; Stage IIIC Ovarian Cancer; Stage IIIC Primary Peritoneal Cancer; Stage IV Fallopian Tube Cancer; Stage IV Ovarian Cancer; Stage IV Primary Peritoneal Cancer
2017-10-23
Fallopian Tube Clear Cell Adenocarcinoma; Fallopian Tube Endometrioid Adenocarcinoma; Fallopian Tube Mucinous Adenocarcinoma; Fallopian Tube Serous Adenocarcinoma; Fallopian Tube Transitional Cell Carcinoma; Malignant Ovarian Mixed Epithelial Tumor; Ovarian Brenner Tumor; Ovarian Clear Cell Adenocarcinoma; Ovarian Endometrioid Adenocarcinoma; Ovarian Mucinous Adenocarcinoma; Ovarian Serous Adenocarcinoma; Ovarian Transitional Cell Carcinoma; Primary Peritoneal Serous Adenocarcinoma; Stage IIIA Fallopian Tube Cancer; Stage IIIA Ovarian Cancer; Stage IIIA Primary Peritoneal Cancer; Stage IIIB Fallopian Tube Cancer; Stage IIIB Ovarian Cancer; Stage IIIB Primary Peritoneal Cancer; Stage IIIC Fallopian Tube Cancer; Stage IIIC Ovarian Cancer; Stage IIIC Primary Peritoneal Cancer; Stage IV Fallopian Tube Cancer; Stage IV Ovarian Cancer; Stage IV Primary Peritoneal Cancer; Undifferentiated Fallopian Tube Carcinoma; Undifferentiated Ovarian Carcinoma
2018-05-03
Fallopian Tube Clear Cell Adenocarcinoma; Fallopian Tube Endometrioid Adenocarcinoma; Fallopian Tube Mucinous Adenocarcinoma; Fallopian Tube Serous Adenocarcinoma; Ovarian Clear Cell Adenocarcinoma; Ovarian Endometrioid Adenocarcinoma; Ovarian Mucinous Adenocarcinoma; Ovarian Serous Adenocarcinoma; Primary Peritoneal Serous Adenocarcinoma; Recurrent Fallopian Tube Carcinoma; Recurrent Ovarian Carcinoma; Recurrent Primary Peritoneal Carcinoma; Undifferentiated Fallopian Tube Carcinoma; Undifferentiated Ovarian Carcinoma
2017-05-02
Fallopian Tube Clear Cell Adenocarcinoma; Fallopian Tube Endometrioid Adenocarcinoma; Fallopian Tube Mucinous Adenocarcinoma; Fallopian Tube Serous Adenocarcinoma; Fallopian Tube Transitional Cell Carcinoma; Ovarian Brenner Tumor; Ovarian Clear Cell Adenocarcinoma; Ovarian Endometrioid Adenocarcinoma; Ovarian Mucinous Adenocarcinoma; Ovarian Seromucinous Carcinoma; Ovarian Serous Adenocarcinoma; Ovarian Transitional Cell Tumor; Primary Peritoneal Serous Adenocarcinoma; Recurrent Fallopian Tube Carcinoma; Recurrent Ovarian Carcinoma; Recurrent Primary Peritoneal Carcinoma; Undifferentiated Fallopian Tube Carcinoma; Undifferentiated Ovarian Carcinoma
Technique for CT Fluoroscopy-Guided Lumbar Medial Branch Blocks and Radiofrequency Ablation.
Amrhein, Timothy J; Joshi, Anand B; Kranz, Peter G
2016-09-01
The purpose of this study is to describe the procedure for CT fluoroscopy-guided lumbar medial branch blocks and facet radiofrequency ablation. CT fluoroscopic guidance allows more-precise needle tip positioning and is an alternative method for performing medial branch blocks and facet radiofrequency ablation.
2018-04-27
Recurrent Fallopian Tube Carcinoma; Recurrent Ovarian Carcinoma; Recurrent Primary Peritoneal Carcinoma; Stage IIA Fallopian Tube Cancer; Stage IIA Ovarian Cancer; Stage IIB Fallopian Tube Cancer; Stage IIB Ovarian Cancer; Stage IIC Fallopian Tube Cancer; Stage IIC Ovarian Cancer; Stage IIIA Fallopian Tube Cancer; Stage IIIA Ovarian Cancer; Stage IIIA Primary Peritoneal Cancer; Stage IIIB Fallopian Tube Cancer; Stage IIIB Ovarian Cancer; Stage IIIB Primary Peritoneal Cancer; Stage IIIC Fallopian Tube Cancer; Stage IIIC Ovarian Cancer; Stage IIIC Primary Peritoneal Cancer; Stage IV Fallopian Tube Cancer; Stage IV Ovarian Cancer; Stage IV Primary Peritoneal Cancer
2017-12-28
Fallopian Tube Endometrioid Adenocarcinoma; Fallopian Tube Mucinous Adenocarcinoma; Fallopian Tube Transitional Cell Carcinoma; Malignant Ovarian Mixed Epithelial Tumor; Ovarian Brenner Tumor; Ovarian Clear Cell Adenocarcinofibroma; Ovarian Endometrioid Adenocarcinoma; Ovarian Mucinous Adenocarcinoma; Ovarian Serous Adenocarcinoma; Ovarian Transitional Cell Carcinoma; Primary Peritoneal Serous Adenocarcinoma; Stage IIA Fallopian Tube Cancer; Stage IIA Ovarian Cancer; Stage IIB Fallopian Tube Cancer; Stage IIB Ovarian Cancer; Stage IIC Fallopian Tube Cancer; Stage IIC Ovarian Cancer; Stage IIIA Fallopian Tube Cancer; Stage IIIA Ovarian Cancer; Stage IIIA Primary Peritoneal Cancer; Stage IIIB Fallopian Tube Cancer; Stage IIIB Ovarian Cancer; Stage IIIB Primary Peritoneal Cancer; Stage IIIC Fallopian Tube Cancer; Stage IIIC Ovarian Cancer; Stage IIIC Primary Peritoneal Cancer; Stage IV Fallopian Tube Cancer; Stage IV Ovarian Cancer; Stage IV Primary Peritoneal Cancer; Undifferentiated Ovarian Carcinoma
Lerman, Imanuel R; Souzdalnitski, Dmitri; Narouze, Samer
2012-01-01
This technical report describes a durable, low-cost, anatomically accurate, and easy-to-prepare combined ultrasound (US) and fluoroscopic phantom of the cervical spine. This phantom is meant to augment training in US- and fluoroscopic-guided pain medicine procedures. The combined US and fluoroscopic phantom (CUF-P) is prepared from commercially available liquid plastic that is ordinarily used to prepare synthetic fishing lures. The liquid plastic is heated and then poured into a metal canister that houses an anatomical cervical spine model. Drops of dark purple dye are added to make the phantom opaque. After cooling, tubing is attached to the CUF-P to simulate blood vessels. The CUF-P accurately simulates human tissue by imitating both the tactile texture of skin and the haptic resistance of human tissue as the needle is advanced. This phantom contains simulated fluid-filled vertebral arteries that exhibit pulsed flow under color Doppler US. Under fluoroscopic examination, the CUF-P-simulated vertebral arteries also exhibit uptake of contrast dye if mistakenly injected. The creation of a training phantom allows the pain physician to practice needle positioning technique while simultaneously visualizing both targeted and avoidable vascular structures under US and fluoroscopic guidance. This low-cost CUF-P is easy to prepare and is reusable, making it an attractive alternative to current homemade and commercially available phantom simulators.
Hoffmann, Michael; Schröder, Malte; Lehmann, Wolfgang; Kammal, Michael; Rueger, Johannes Maria; Herrman Ruecker, Andreas
2012-07-01
Distal locking marks one challenging step during intramedullary nailing that can lead to an increased irradiation and prolonged operation times. The aim of this study was to evaluate the reliability and efficacy of an X-ray-radiation-free real-time navigation system for distal locking procedures. A prospective randomized cadaver study with 50 standard free-hand fluoroscopic-guided and 50 electromagnetic-guided distal locking procedures was performed. All procedures were timed using a stopwatch. Intraoperative fluoroscopy exposure time and absorbed radiation dose (mGy) readings were documented. All tibial nails were locked with two mediolateral and one anteroposterior screw. Successful distal locking was accomplished once correct placement of all three screws was confirmed. Successful distal locking was achieved in 98 cases. No complications were encountered using the electromagnetic navigation system. Eight complications arose during free-hand fluoroscopic distal locking. Undetected secondary drill slippage on the ipsilateral cortex accounted for most problems followed by undetected intradrilling misdirection causing a fissural fracture of the contralateral cortex while screw insertion in one case. Compared with the free-hand fluoroscopic technique, electromagnetically navigated distal locking provides a median time benefit of 244 seconds without using ionizing radiation. Compared with the standard free-hand fluoroscopic technique, the electromagnetic guidance system used in this study showed high reliability and was associated with less complications, took significantly less time, and used no radiation exposure for distal locking procedures. Therapeutic study, level II.
Cook, J L; Tomlinson, J L; Reed, A L
1999-01-01
To report a technique for fluoroscopically guided closed reduction with internal fixation of fractures of the lateral portion of the humeral condyle (FLHC) and determine the long-term results in 10 clinical cases. Prospective clinical case study. Ten dogs with 11 fractures. Fractures of the lateral portion of the humeral condyle were stabilized with transcondylar screws and Kirschner wires. Closed reduction and implant placement were achieved using intraoperative fluoroscopic guidance. After fracture repair, postoperative radiographs were evaluated for articular alignment and implant placement. Dogs were evaluated after surgery by means of lameness scores, elbow range of motion (ROM), radiographic assessment, and owner evaluation of function. Postoperative reduction was considered anatomic in 6 fractures with all other fractures having <1.5 mm of malreduction. Follow-up was available for 9 patients from 9 to 21 months after surgery. All of the fractures had healed. One minor (wire migration) and one major (implant failure) complication occurred. Mean lameness scores were 0 (n = 6), 0.5 (n = 2), and 1 (n = 1) at the time of final follow-up. No significant differences were found in follow-up ROM values between affected and unaffected elbows. All of the dogs in this study regained 90-100% of full function, based on owner assessment. Fluoroscopic guidance for closed reduction and internal fixation of FLHC in dogs is an effective technique.
2013-12-17
Recurrent Fallopian Tube Cancer; Recurrent Ovarian Epithelial Cancer; Recurrent Primary Peritoneal Cavity Cancer; Stage IA Fallopian Tube Cancer; Stage IA Ovarian Epithelial Cancer; Stage IA Primary Peritoneal Cavity Cancer; Stage IB Fallopian Tube Cancer; Stage IB Ovarian Epithelial Cancer; Stage IB Primary Peritoneal Cavity Cancer; Stage IC Fallopian Tube Cancer; Stage IC Ovarian Epithelial Cancer; Stage IC Primary Peritoneal Cavity Cancer; Stage IIA Fallopian Tube Cancer; Stage IIA Ovarian Epithelial Cancer; Stage IIA Primary Peritoneal Cavity Cancer; Stage IIB Fallopian Tube Cancer; Stage IIB Ovarian Epithelial Cancer; Stage IIB Primary Peritoneal Cavity Cancer; Stage IIC Fallopian Tube Cancer; Stage IIC Ovarian Epithelial Cancer; Stage IIC Primary Peritoneal Cavity Cancer; Stage IIIA Fallopian Tube Cancer; Stage IIIA Ovarian Epithelial Cancer; Stage IIIA Primary Peritoneal Cavity Cancer; Stage IIIB Fallopian Tube Cancer; Stage IIIB Ovarian Epithelial Cancer; Stage IIIB Primary Peritoneal Cavity Cancer; Stage IIIC Fallopian Tube Cancer; Stage IIIC Ovarian Epithelial Cancer; Stage IIIC Primary Peritoneal Cavity Cancer; Stage IV Fallopian Tube Cancer; Stage IV Ovarian Epithelial Cancer; Stage IV Primary Peritoneal Cavity Cancer
2018-03-22
Fallopian Tube Carcinosarcoma; Fallopian Tube Clear Cell Adenocarcinoma; Fallopian Tube Endometrioid Adenocarcinoma; Fallopian Tube Mucinous Adenocarcinoma; Fallopian Tube Serous Neoplasm; Fallopian Tube Transitional Cell Carcinoma; Ovarian Brenner Tumor; Ovarian Carcinosarcoma; Ovarian Clear Cell Adenocarcinoma; Ovarian Endometrioid Adenocarcinoma; Ovarian Mucinous Adenocarcinoma; Ovarian Seromucinous Tumor; Ovarian Serous Adenocarcinoma; Ovarian Transitional Cell Carcinoma; Primary Peritoneal Serous Adenocarcinoma; Stage IIA Fallopian Tube Cancer AJCC v6 and v7; Stage IIA Ovarian Cancer AJCC V6 and v7; Stage IIB Fallopian Tube Cancer AJCC v6 and v7; Stage IIB Ovarian Cancer AJCC v6 and v7; Stage IIC Fallopian Tube Cancer AJCC v6 and v7; Stage IIC Ovarian Cancer AJCC v6 and v7; Stage IIIA Fallopian Tube Cancer AJCC v7; Stage IIIA Ovarian Cancer AJCC v6 and v7; Stage IIIA Primary Peritoneal Cancer AJCC v7; Stage IIIB Fallopian Tube Cancer AJCC v7; Stage IIIB Ovarian Cancer AJCC v6 and v7; Stage IIIB Primary Peritoneal Cancer AJCC v7; Stage IIIC Fallopian Tube Cancer AJCC v7; Stage IIIC Ovarian Cancer AJCC v6 and v7; Stage IIIC Primary Peritoneal Cancer AJCC v7; Stage IV Fallopian Tube Cancer AJCC v6 and v7; Stage IV Ovarian Cancer AJCC v6 and v7; Stage IV Primary Peritoneal Cancer AJCC v7; Undifferentiated Fallopian Tube Carcinoma; Undifferentiated Ovarian Carcinoma
2018-06-06
Clear Cell Adenocarcinoma; Fallopian Tube Clear Cell Adenocarcinoma; Fallopian Tube Endometrioid Adenocarcinoma; Fallopian Tube Mucinous Adenocarcinoma; Fallopian Tube Serous Adenocarcinoma; Mucinous Adenocarcinoma; Ovarian Brenner Tumor; Ovarian Clear Cell Adenocarcinofibroma; Ovarian Endometrioid Adenocarcinoma; Ovarian Seromucinous Carcinoma; Ovarian Serous Adenocarcinoma; Primary Peritoneal Serous Adenocarcinoma; Recurrent Fallopian Tube Carcinoma; Recurrent Ovarian Carcinoma; Recurrent Primary Peritoneal Carcinoma; Undifferentiated Carcinoma; Undifferentiated Fallopian Tube Carcinoma; Undifferentiated Ovarian Carcinoma
2018-06-15
Deleterious BRCA1 Gene Mutation; Deleterious BRCA2 Gene Mutation; Fallopian Tube Clear Cell Adenocarcinoma; Fallopian Tube Endometrioid Adenocarcinoma; Fallopian Tube Serous Adenocarcinoma; Fallopian Tube Transitional Cell Carcinoma; Ovarian Clear Cell Adenocarcinoma; Ovarian Endometrioid Adenocarcinoma; Ovarian Seromucinous Carcinoma; Ovarian Serous Adenocarcinoma; Ovarian Transitional Cell Carcinoma; Primary Peritoneal Serous Adenocarcinoma; Recurrent Fallopian Tube Carcinoma; Recurrent Ovarian Carcinoma; Recurrent Primary Peritoneal Carcinoma; Undifferentiated Fallopian Tube Carcinoma; Undifferentiated Ovarian Carcinoma
2017-08-28
Recurrent Breast Carcinoma; Recurrent Fallopian Tube Carcinoma; Recurrent Ovarian Carcinoma; Recurrent Primary Peritoneal Carcinoma; Stage IIA Breast Cancer; Stage IIA Fallopian Tube Cancer; Stage IIA Ovarian Cancer; Stage IIB Breast Cancer; Stage IIB Fallopian Tube Cancer; Stage IIB Ovarian Cancer; Stage IIC Fallopian Tube Cancer; Stage IIC Ovarian Cancer; Stage IIIA Breast Cancer; Stage IIIA Fallopian Tube Cancer; Stage IIIA Ovarian Cancer; Stage IIIA Primary Peritoneal Cancer; Stage IIIB Breast Cancer; Stage IIIB Fallopian Tube Cancer; Stage IIIB Ovarian Cancer; Stage IIIB Primary Peritoneal Cancer; Stage IIIC Breast Cancer; Stage IIIC Fallopian Tube Cancer; Stage IIIC Ovarian Cancer; Stage IIIC Primary Peritoneal Cancer; Stage IV Fallopian Tube Cancer; Stage IV Ovarian Cancer; Stage IV Primary Peritoneal Cancer
2018-02-14
Fallopian Tube Clear Cell Adenocarcinoma; Fallopian Tube Endometrioid Adenocarcinoma; Fallopian Tube Mucinous Adenocarcinoma; Fallopian Tube Serous Adenocarcinoma; Fallopian Tube Transitional Cell Carcinoma; Malignant Ovarian Brenner Tumor; Ovarian Clear Cell Adenocarcinoma; Ovarian Endometrioid Adenocarcinoma; Ovarian Mucinous Adenocarcinoma; Ovarian Seromucinous Carcinoma; Ovarian Serous Adenocarcinoma; Ovarian Transitional Cell Carcinoma; Primary Peritoneal Serous Adenocarcinoma; Stage IIA Fallopian Tube Cancer AJCC v6 and v7; Stage IIA Ovarian Cancer AJCC V6 and v7; Stage IIB Fallopian Tube Cancer AJCC v6 and v7; Stage IIB Ovarian Cancer AJCC v6 and v7; Stage IIC Fallopian Tube Cancer AJCC v6 and v7; Stage IIC Ovarian Cancer AJCC v6 and v7; Stage IIIA Fallopian Tube Cancer AJCC v7; Stage IIIA Ovarian Cancer AJCC v6 and v7; Stage IIIA Primary Peritoneal Cancer AJCC v7; Stage IIIB Fallopian Tube Cancer AJCC v7; Stage IIIB Ovarian Cancer AJCC v6 and v7; Stage IIIB Primary Peritoneal Cancer AJCC v7; Stage IIIC Fallopian Tube Cancer AJCC v7; Stage IIIC Ovarian Cancer AJCC v6 and v7; Stage IIIC Primary Peritoneal Cancer AJCC v7; Stage IV Fallopian Tube Cancer AJCC v6 and v7; Stage IV Ovarian Cancer AJCC v6 and v7; Stage IV Primary Peritoneal Cancer AJCC v7; Undifferentiated Fallopian Tube Carcinoma; Undifferentiated Ovarian Carcinoma
2018-06-20
Fallopian Tube Clear Cell Adenocarcinoma; Fallopian Tube Endometrioid Adenocarcinoma; High Grade Fallopian Tube Serous Adenocarcinoma; High Grade Ovarian Serous Adenocarcinoma; Ovarian Clear Cell Adenocarcinoma; Ovarian Endometrioid Adenocarcinoma; Ovarian Seromucinous Carcinoma; Primary Peritoneal High Grade Serous Adenocarcinoma; Recurrent Fallopian Tube Carcinoma; Recurrent Ovarian Carcinoma; Recurrent Primary Peritoneal Carcinoma; Undifferentiated Fallopian Tube Carcinoma; Undifferentiated Ovarian Carcinoma
2018-03-28
Recurrent Fallopian Tube Cancer; Recurrent Ovarian Epithelial Cancer; Recurrent Primary Peritoneal Cavity Cancer; Stage IIA Fallopian Tube Cancer; Stage IIA Ovarian Epithelial Cancer; Stage IIA Primary Peritoneal Cavity Cancer; Stage IIB Fallopian Tube Cancer; Stage IIB Ovarian Epithelial Cancer; Stage IIB Primary Peritoneal Cavity Cancer; Stage IIC Fallopian Tube Cancer; Stage IIC Ovarian Epithelial Cancer; Stage IIC Primary Peritoneal Cavity Cancer; Stage IIIA Fallopian Tube Cancer; Stage IIIA Ovarian Epithelial Cancer; Stage IIIA Primary Peritoneal Cavity Cancer; Stage IIIB Fallopian Tube Cancer; Stage IIIB Ovarian Epithelial Cancer; Stage IIIB Primary Peritoneal Cavity Cancer; Stage IIIC Fallopian Tube Cancer; Stage IIIC Ovarian Epithelial Cancer; Stage IIIC Primary Peritoneal Cavity Cancer; Stage IV Fallopian Tube Cancer; Stage IV Ovarian Epithelial Cancer; Stage IV Primary Peritoneal Cavity Cancer
Design of an everting balloon to deploy a microendoscope to the fallopian tubes
NASA Astrophysics Data System (ADS)
Keenan, Molly; Howard, Caitlin; Tate, Tyler; McGuiness, Ian; Sauer-Budge, Alexis; Black, John; Utzinger, Urs; Barton, Jennifer K.
2016-02-01
The 5-year survival rate for ovarian cancer is only 45% largely due to lack of effective screening methods. Current methods include palpation, transvaginal ultrasound, and the CA-125 blood test. Finding disease reliably and at an early stage increase survival to 92%. We have designed and built a 0.7 mm endoscope for the early detection of ovarian cancer. Inserted transvaginally through the working channel of a hysteroscope, the falloposcope creates a minimally invasive procedure for the screening of high risk women. To improve the ease-of-use and safety of falloposcope deployment, we are working to create an everting balloon. Currently, the falloposcope would require a skilled user to operate due to the challenging anatomy of the fallopian tubes - a small opening from the uterus (< 1 mm), tortuous path, and delicate lumenal features. A balloon delivery system would gently open the fallopian tube and guide the falloposcope down the center of lumen. We show balloon design and discuss integration with the falloposcope prototype. We test possible mechanical damage to the tissue due to scraping, puncture, or overstretching. Successful introduction of the everting balloon to simplify falloposcope delivery could expand screening beyond specialized centers to smaller clinical locations.
2018-01-09
Mixed Mesodermal (Mullerian) Tumor; Ovarian Carcinosarcoma; Recurrent Fallopian Tube Carcinoma; Recurrent Ovarian Carcinoma; Recurrent Primary Peritoneal Carcinoma; Stage I Ovarian Cancer; Stage IA Fallopian Tube Cancer; Stage IA Ovarian Cancer; Stage IA Uterine Sarcoma AJCC v7; Stage IB Fallopian Tube Cancer; Stage IB Ovarian Cancer; Stage IB Uterine Sarcoma AJCC v7; Stage IC Fallopian Tube Cancer; Stage IC Ovarian Cancer; Stage IC Uterine Sarcoma AJCC v7; Stage II Ovarian Cancer; Stage IIA Fallopian Tube Cancer; Stage IIA Ovarian Cancer; Stage IIA Uterine Sarcoma AJCC v7; Stage IIB Fallopian Tube Cancer; Stage IIB Ovarian Cancer; Stage IIB Uterine Sarcoma AJCC v7; Stage IIC Fallopian Tube Cancer; Stage IIC Ovarian Cancer; Stage IIIA Fallopian Tube Cancer; Stage IIIA Ovarian Cancer; Stage IIIA Primary Peritoneal Cancer; Stage IIIA Uterine Sarcoma AJCC v7; Stage IIIB Fallopian Tube Cancer; Stage IIIB Ovarian Cancer; Stage IIIB Primary Peritoneal Cancer; Stage IIIB Uterine Sarcoma AJCC v7; Stage IIIC Fallopian Tube Cancer; Stage IIIC Ovarian Cancer; Stage IIIC Primary Peritoneal Cancer; Stage IIIC Uterine Sarcoma AJCC v7; Stage IV Fallopian Tube Cancer; Stage IV Ovarian Cancer; Stage IV Primary Peritoneal Cancer; Stage IVA Uterine Sarcoma AJCC v7; Stage IVB Uterine Sarcoma AJCC v7; Uterine Carcinosarcoma
DOE Office of Scientific and Technical Information (OSTI.GOV)
Damilakis, J; Stratakis, J; Solomou, G
Purpose: It is well known that pacemaker implantation is sometimes needed in pregnant patients with symptomatic bradycardia. To our knowledge, there is no reported experience regarding radiation doses to the unborn child resulting from fluoroscopy during pacemaker implantation. The purpose of the current study was to develop a method for estimating embryo/fetus dose from fluoroscopically guided pacemaker implantation procedures performed on pregnant patients during all trimesters of gestation. Methods: The Monte Carlo N-Particle (MCNP) radiation transport code was employed in this study. Three mathematical anthropomorphic phantoms representing the average pregnant patient at the first, second and third trimesters of gestationmore » were generated using Bodybuilder software (White Rock science, White Rock, NM). The normalized embryo/fetus dose from the posteroanterior (PA), the 30° left-anterior oblique (LAO) and the 30° right-anterior oblique (RAO) projections were calculated for a wide range of kVp (50–120 kVp) and total filtration values (2.5–9.0 mm Al). Results: The results consist of radiation doses normalized to a) entrance skin dose (ESD) and b) dose area product (DAP) so that the dose to the unborn child from any fluoroscopic technique and x-ray device used can be calculated. ESD normalized doses ranged from 0.008 (PA, first trimester) to 2.519 μGy/mGy (RAO, third trimester). DAP normalized doses ranged from 0.051 (PA, first trimester) to 12.852 μGy/Gycm2 (RAO, third trimester). Conclusion: Embryo/fetus doses from fluoroscopically guided pacemaker implantation procedures performed on pregnant patients during all stages of gestation can be estimated using the method developed in this study. This study was supported by the Greek Ministry of Education and Religious Affairs, General Secretariat for Research and Technology, Operational Program ‘Education and Lifelong Learning’, ARISTIA (Research project: CONCERT)« less
Walsh, Katie A; Galvin, Joseph; Keaney, John; Keelan, Edward; Szeplaki, Gabor
2018-02-23
Zero- and near-zero-fluoroscopic ablation techniques reduce the harmful effects of ionizing radiation during invasive electrophysiology procedures. We aimed to test the feasibility and safety of a zero-fluoroscopic strategy using a novel integrated magnetic and impedance-based electroanatomical mapping system for radiofrequency ablation (RFA) of supraventricular tachycardias (SVTs). We retrospectively studied 92 consecutive patients undergoing electrophysiology studies with/without RFA for supraventricular tachycardia (SVT) performed by a single operator at a single center. The first 42 (Group 1) underwent a conventional fluoroscopic-guided approach and the second 50 (Group 2) underwent a zero-fluoroscopic approach using the Ensite Precision ™ 3-D magnetic and impedance-based mapping system (Abbott Inc). Group 1 comprised 14 AV-nodal re-entrant tachycardia (AVNRT), 12 typical atrial flutter, 4 accessory pathway (AP), 2 atrial tachycardia (AT), and 9 diagnostic EP studies (EPS). Group 2 comprised 16 AVNRT, 17 atrial flutter, 6 AP, 3 AT, 2 AV-nodal ablations, and 7 EPS. A complete zero-fluoroscopic approach was achieved in 94% of Group 2 patients. All procedures were acutely successful, and no complications occurred. There was a significant reduction in fluoroscopy dose, dose area product, and time (p < 0.0001, for all), with no difference in procedure times. Ablation time for typical atrial flutter was shorter in Group 2 (p = 0.006). A zero-fluoroscopic strategy for diagnosis and treatment of SVTs using this novel 3D-electroanatomical mapping system is feasible in majority of patients, is safe, reduces ionizing radiation exposure, and does not compromise procedural times, success rates, or complication rates.
Xu, Q Y; Yin, G W; Chen, S X; Jiang, F; Bai, X J; Wu, J D
2012-11-01
The aim of this study was to retrospectively evaluate the technical success rates and clinical effectiveness of fluoroscopically guided nose tube drainage of mediastinal abscesses and a nasojejunum feeding tube in post-operative gastro-oesophageal anastomotic leakage (GEAL). From January 2006 to June 2011, 18 cases of post-operative GEAL with mediastinal abscesses after oesophagectomy with intrathoracic oesophagogastric anastomotic procedures for oesophageal and cardiac carcinoma were treated by insertion of a nose drainage tube and nasojejunum feeding tube under fluoroscopic guidance. We evaluated the feasibility of two-tube insertion to facilitate leakage site closure and complete resolution of the abscess, and the patients' nutritional benefit was also evaluated by checking the serum albumin level between pre- and post-enteral feeding via the feeding tube. The two tubes were placed successfully under fluoroscopic guidance in 18 patients (100%). The procedure time for two-tube insertion ranged from 20 to 40 min (mean 30 min). 17 patients (94%) achieved leakage site closure after two-tube insertion and had a good tolerance of two tubes in the nasal cavity. The serum albumin level was significant, increased from pre-enteral feeding (2.49 ± 0.42 g dl(-1)) to the post-enteral feeding (3.58 ± 0.47 g dl(-1)) via the feeding tube (p<0.001). The duration of follow-up ranged from 1 to 49 months (mean 19 months). The insertion of nose tube drainage and a nasojejunum feeding tube under fluoroscopic guidance is safe, and it provides effective relief from mediastinal abscesses in GEAL after oesophagectomy. Moreover, our findings indicate that two-tube insertion may be used as a selective procedure to treat mediastinal abscesses in post-operative GEAL. Advances in knowledge Directive drainage of mediastinal abscesses in post-operative GEAL may be an effective treatment.
Three-dimensional curvilinear device reconstruction from two fluoroscopic views
NASA Astrophysics Data System (ADS)
Delmas, Charlotte; Berger, Marie-Odile; Kerrien, Erwan; Riddell, Cyril; Trousset, Yves; Anxionnat, René; Bracard, Serge
2015-03-01
In interventional radiology, navigating devices under the sole guidance of fluoroscopic images inside a complex architecture of tortuous and narrow vessels like the cerebral vascular tree is a difficult task. Visualizing the device in 3D could facilitate this navigation. For curvilinear devices such as guide-wires and catheters, a 3D reconstruction may be achieved using two simultaneous fluoroscopic views, as available on a biplane acquisition system. The purpose of this paper is to present a new automatic three-dimensional curve reconstruction method that has the potential to reconstruct complex 3D curves and does not require a perfect segmentation of the endovascular device. Using epipolar geometry, our algorithm translates the point correspondence problem into a segment correspondence problem. Candidate 3D curves can be formed and evaluated independently after identifying all possible combinations of compatible 3D segments. Correspondence is then inherently solved by looking in 3D space for the most coherent curve in terms of continuity and curvature. This problem can be cast into a graph problem where the most coherent curve corresponds to the shortest path of a weighted graph. We present quantitative results of curve reconstructions performed from numerically simulated projections of tortuous 3D curves extracted from cerebral vascular trees affected with brain arteriovenous malformations as well as fluoroscopic image pairs of a guide-wire from both phantom and clinical sets. Our method was able to select the correct 3D segments in 97.5% of simulated cases thus demonstrating its ability to handle complex 3D curves and can deal with imperfect 2D segmentation.
2018-05-25
Malignant Ovarian Mixed Epithelial Tumor; Ovarian Brenner Tumor; Ovarian Clear Cell Cystadenocarcinoma; Ovarian Endometrioid Adenocarcinoma; Ovarian Mucinous Cystadenocarcinoma; Ovarian Serous Cystadenocarcinoma; Stage IIA Fallopian Tube Cancer; Stage IIA Ovarian Cancer; Stage IIB Fallopian Tube Cancer; Stage IIB Ovarian Cancer; Stage IIC Fallopian Tube Cancer; Stage IIC Ovarian Cancer; Stage IIIA Fallopian Tube Cancer; Stage IIIA Ovarian Cancer; Stage IIIA Primary Peritoneal Cancer; Stage IIIB Fallopian Tube Cancer; Stage IIIB Ovarian Cancer; Stage IIIB Primary Peritoneal Cancer; Stage IIIC Fallopian Tube Cancer; Stage IIIC Ovarian Cancer; Stage IIIC Primary Peritoneal Cancer; Undifferentiated Ovarian Carcinoma
2018-05-01
Stage III Fallopian Tube Cancer; Stage III Ovarian Cancer; Stage III Primary Peritoneal Cancer; Stage IIIA Fallopian Tube Cancer; Stage IIIA Ovarian Cancer; Stage IIIA Primary Peritoneal Cancer; Stage IIIB Fallopian Tube Cancer; Stage IIIB Ovarian Cancer; Stage IIIB Primary Peritoneal Cancer; Stage IIIC Fallopian Tube Cancer; Stage IIIC Ovarian Cancer; Stage IIIC Primary Peritoneal Cancer; Stage IV Fallopian Tube Cancer; Stage IV Ovarian Cancer; Stage IV Primary Peritoneal Cancer
2015-01-15
Recurrent Fallopian Tube Cancer; Recurrent Ovarian Epithelial Cancer; Recurrent Primary Peritoneal Cavity Cancer; Stage IIIA Fallopian Tube Cancer; Stage IIIA Ovarian Epithelial Cancer; Stage IIIA Primary Peritoneal Cavity Cancer; Stage IIIB Fallopian Tube Cancer; Stage IIIB Ovarian Epithelial Cancer; Stage IIIB Primary Peritoneal Cavity Cancer; Stage IIIC Fallopian Tube Cancer; Stage IIIC Ovarian Epithelial Cancer; Stage IIIC Primary Peritoneal Cavity Cancer; Stage IV Fallopian Tube Cancer; Stage IV Ovarian Epithelial Cancer; Stage IV Primary Peritoneal Cavity Cancer
2018-02-14
Fallopian Tube Clear Cell Adenocarcinoma; Fallopian Tube Endometrioid Adenocarcinoma; Fallopian Tube Serous Neoplasm; High Grade Ovarian Serous Adenocarcinoma; Ovarian Clear Cell Adenocarcinoma; Ovarian Endometrioid Adenocarcinoma; Primary Peritoneal Serous Adenocarcinoma; Stage III Fallopian Tube Cancer AJCC v7; Stage III Ovarian Cancer AJCC v6 and v7; Stage III Primary Peritoneal Cancer AJCC v7; Stage IIIA Fallopian Tube Cancer AJCC v7; Stage IIIA Ovarian Cancer AJCC v6 and v7; Stage IIIA Primary Peritoneal Cancer AJCC v7; Stage IIIB Fallopian Tube Cancer AJCC v7; Stage IIIB Ovarian Cancer AJCC v6 and v7; Stage IIIB Primary Peritoneal Cancer AJCC v7; Stage IIIC Fallopian Tube Cancer AJCC v7; Stage IIIC Ovarian Cancer AJCC v6 and v7; Stage IIIC Primary Peritoneal Cancer AJCC v7; Stage IV Fallopian Tube Cancer AJCC v6 and v7; Stage IV Ovarian Cancer AJCC v6 and v7; Stage IV Primary Peritoneal Cancer AJCC v7
C-arm positioning using virtual fluoroscopy for image-guided surgery
NASA Astrophysics Data System (ADS)
de Silva, T.; Punnoose, J.; Uneri, A.; Goerres, J.; Jacobson, M.; Ketcha, M. D.; Manbachi, A.; Vogt, S.; Kleinszig, G.; Khanna, A. J.; Wolinsky, J.-P.; Osgood, G.; Siewerdsen, J. H.
2017-03-01
Introduction: Fluoroscopically guided procedures often involve repeated acquisitions for C-arm positioning at the cost of radiation exposure and time in the operating room. A virtual fluoroscopy system is reported with the potential of reducing dose and time spent in C-arm positioning, utilizing three key advances: robust 3D-2D registration to a preoperative CT; real-time forward projection on GPU; and a motorized mobile C-arm with encoder feedback on C-arm orientation. Method: Geometric calibration of the C-arm was performed offline in two rotational directions (orbit α, orbit β). Patient registration was performed using image-based 3D-2D registration with an initially acquired radiograph of the patient. This approach for patient registration eliminated the requirement for external tracking devices inside the operating room, allowing virtual fluoroscopy using commonly available systems in fluoroscopically guided procedures within standard surgical workflow. Geometric accuracy was evaluated in terms of projection distance error (PDE) in anatomical fiducials. A pilot study was conducted to evaluate the utility of virtual fluoroscopy to aid C-arm positioning in image guided surgery, assessing potential improvements in time, dose, and agreement between the virtual and desired view. Results: The overall geometric accuracy of DRRs in comparison to the actual radiographs at various C-arm positions was PDE (mean ± std) = 1.6 ± 1.1 mm. The conventional approach required on average 8.0 ± 4.5 radiographs spent "fluoro hunting" to obtain the desired view. Positioning accuracy improved from 2.6o ± 2.3o (in α) and 4.1o ± 5.1o (in β) in the conventional approach to 1.5o ± 1.3o and 1.8o ± 1.7o, respectively, with the virtual fluoroscopy approach. Conclusion: Virtual fluoroscopy could improve accuracy of C-arm positioning and save time and radiation dose in the operating room. Such a system could be valuable to training of fluoroscopy technicians as well as intraoperative use in fluoroscopically guided procedures.
[Clinical Value of Prophylactic Salpingectomy in Hysterectomy due to Uterine Benign Lesions].
Zhao, Ling-Jun; Wang, Ping; Li, Xiu-Ying
2017-03-01
To explore the clinical value of resection of bilateral fallopian tubes in patients with benign uterine diseases who received (laparoscopic) hysterectomy or subhysterectomy through the postoperative pathologic analysis of resected fallopian tubes. A retrospective analysis was conducted to review the histopathological examination results in 1 272 women who underwent (laparoscopic) total hysterectomy or subtotal hysterectomy and the removal of bilateral fallopian tube simultaneously due to uterine leiomyoma, adenomyosis and other benign lesions from December 2010 to December 2015. Of the 1 272 patients, laparoscopic resection was underwent in 1 005 patients (79.01%) and laparotomy in 267 patients (20.99%). In the attachment area, 334 patients (26.26%) had tenderness signs, and 401 patients (31.53%) had signs of thickening. Total 2 498 fallopian tubes were removed. There were 1 654 tubal with no obvious abnormal appearance (66.21%), 636 tubal with lumen part of the uplift (25.46%), 128 fallopian tube with congestion and swelling (5.12%), 80 fallopian tube atrophy adhesions (3.20%). Pathological. showed 2 386 (95.52%) fallopian tubes with chronic fallopian tube inflammation, 988 (39.55%) of fallopian tube cyst, 80 (3.20%) of normal fallopian tube, 78 (3.12%) of tubal effusion, 48 (1.92% ) of tubal hyperplasia, 4 (0.26%) of tubal benign tumor, 8 (0.32%) of tubal mucosa atypical hyperplasia change and 2(0.08%) of tubal cancer. In the 10 cases of fallopian tube cancer and atypical hyperplasia, 8 had obvious changes of chronic inflammation in the contralateral fallopian tube, including 7 cases of atypical hyperplasia and 1 case of fallopian tube cancer. Prophylactic salpingectomy can prevent the occurrence of tubal inflammation and removal cancer incentives.
2018-04-24
Nausea and Vomiting; Ovarian Brenner Tumor; Ovarian Clear Cell Cystadenocarcinoma; Ovarian Endometrioid Adenocarcinoma; Ovarian Mucinous Cystadenocarcinoma; Ovarian Seromucinous Carcinoma; Ovarian Serous Cystadenocarcinoma; Stage II Ovarian Cancer; Stage IIA Fallopian Tube Cancer; Stage IIA Ovarian Cancer; Stage IIB Fallopian Tube Cancer; Stage IIB Ovarian Cancer; Stage IIC Fallopian Tube Cancer; Stage IIC Ovarian Cancer; Stage IIIA Fallopian Tube Cancer; Stage IIIA Ovarian Cancer; Stage IIIA Primary Peritoneal Cancer; Stage IIIB Fallopian Tube Cancer; Stage IIIB Ovarian Cancer; Stage IIIB Primary Peritoneal Cancer; Stage IIIC Fallopian Tube Cancer; Stage IIIC Ovarian Cancer; Stage IIIC Primary Peritoneal Cancer; Stage IV Fallopian Tube Cancer; Stage IV Ovarian Cancer; Stage IV Primary Peritoneal Cancer; Undifferentiated Ovarian Carcinoma
DOE Office of Scientific and Technical Information (OSTI.GOV)
Morikawa, Shigehiro, E-mail: morikawa@belle.shiga-med.ac.jp; Inubushi, Toshiro; Kurumi, Yoshimasa
2004-08-15
We obtained clear and reproducible MR fluoroscopic images and temperature maps for MR image-guided microwave ablation of liver tumors under general anesthesia without suspending the artificial ventilation. Respiratory information was directly obtained from air-way pressure without a sensor on the chest wall. The trigger signal started scanning of one whole image with a spoiled gradient echo sequence. The delay time before the start of scanning was adjusted to acquire the data corresponding to the k-space center at the maximal expiratory phase. The triggered images were apparently clearer than the nontriggered ones and the location of the liver was consistent, whichmore » made targeting of the tumor easy. MR temperature images, which were highly susceptible to the movement of the liver, during microwave ablation using a proton resonance frequency method, could be obtained without suspending the artificial ventilation. Respiratory triggering technique was found to be useful for MR fluoroscopic images and MR temperature monitoring in MR-guided microwave ablation of liver tumors under general anesthesia.« less
Engel, Andrew; Rappard, George; King, Wade; Kennedy, David J
2016-04-01
To determine the effectiveness and risks of fluoroscopically-guided cervical medial branch thermal radiofrequency neurotomy (CMBTRFN) for treating chronic neck pain of zygapophysial joint origin. Systematic review of the literature with comprehensive analysis of the published data. Four reviewers formally trained in evidence-based medicine searched the literature on CMBTRFN. Each assessed the methodologies of studies found and appraised the quality of evidence presented. The primary outcomes assessed were 100% relief of pain 6 and 12 months after treatment. Other outcomes were noted if reported. The evidence was evaluated in accordance with the Grades of Recommendation, Assessment, Development, and Evaluation (GRADE) system. The searches yielded eight primary publications on the effectiveness of the procedure. The evidence shows a majority of patients were pain free at 6 months and over a third were pain free at 1 year. The number needed to treat for complete pain relief at 6 months is 2. The evidence of effectiveness is of high quality according to the GRADE system. Twelve papers were found reporting unwanted effects, most of which are minor and temporary. No serious complications have ever been reported from procedures performed according to the published guidelines. The evidence of risks is of low quality according to the GRADE system. If performed as described in the International Spine Intervention Society Guidelines, fluoroscopically-guided CMBTRFN is effective for abolishing zygapophysial joint pain and carries only minor risks. © 2015 American Academy of Pain Medicine. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
DeGregoris, Gerard; Diwan, Sudhir
2010-01-01
Lower back and extremity pain in the amputee patient can be challenging to classify and treat. Radicular compression in a patient with lower limb amputation may present as or be superimposed upon phantom limb pain, creating diagnostic difficulties. Both patients and physicians classically find it difficult to discern phantom sensation from phantom limb pain and stump pain; radicular compression is often not considered. Many studies have shown back pain to be a significant cause of pain in lower limb amputees, but sciatica has been rarely reported in amputees. We present a case of L4/5 radiculitis in an above-knee amputee presenting as phantom radiculitis. Our patient is a 67 year old gentleman with new onset 10/10 pain in a phantom extremity superimposed upon a 40 year history of previously stable phantom limb pain. MRI showed a central disc herniation at L4/5 with compression of the traversing left L4 nerve root. Two fluoroscopically guided left transforaminal epidural steroid injections at the level of the L4 and L5 spinal nerve roots totally alleviated his new onset pain. At one year post injection, his phantom radiculitis pain was completely gone, though his underlying phantom limb pain remained. Lumbar radiculitis in lower extremity amputee patients may be difficult to differentiate from baseline phantom limb pain. When conservative techniques fail, fluoroscopically guided spinal nerve injection may be valuable in determining the etiology of lower extremity pain. Our experience supports the notion that epidural steroid injections can effectively treat phantom lumbar radiculitis in lower extremity amputees.
2016-02-15
Malignant Ovarian Clear Cell Tumor; Malignant Ovarian Serous Tumor; Recurrent Fallopian Tube Carcinoma; Recurrent Ovarian Carcinoma; Recurrent Primary Peritoneal Carcinoma; Stage IIIA Fallopian Tube Cancer; Stage IIIA Ovarian Cancer; Stage IIIA Primary Peritoneal Cancer; Stage IIIB Fallopian Tube Cancer; Stage IIIB Ovarian Cancer; Stage IIIB Primary Peritoneal Cancer; Stage IIIC Fallopian Tube Cancer; Stage IIIC Ovarian Cancer; Stage IIIC Primary Peritoneal Cancer; Stage IV Fallopian Tube Cancer; Stage IV Ovarian Cancer; Stage IV Primary Peritoneal Cancer
NASA Astrophysics Data System (ADS)
Tanaka, Rie; Sanada, Shigeru; Sakuta, Keita; Kawashima, Hiroki
2015-05-01
The bone suppression technique based on advanced image processing can suppress the conspicuity of bones on chest radiographs, creating soft tissue images obtained by the dual-energy subtraction technique. This study was performed to evaluate the usefulness of bone suppression image processing in image-guided radiation therapy. We demonstrated the improved accuracy of markerless motion tracking on bone suppression images. Chest fluoroscopic images of nine patients with lung nodules during respiration were obtained using a flat-panel detector system (120 kV, 0.1 mAs/pulse, 5 fps). Commercial bone suppression image processing software was applied to the fluoroscopic images to create corresponding bone suppression images. Regions of interest were manually located on lung nodules and automatic target tracking was conducted based on the template matching technique. To evaluate the accuracy of target tracking, the maximum tracking error in the resulting images was compared with that of conventional fluoroscopic images. The tracking errors were decreased by half in eight of nine cases. The average maximum tracking errors in bone suppression and conventional fluoroscopic images were 1.3 ± 1.0 and 3.3 ± 3.3 mm, respectively. The bone suppression technique was especially effective in the lower lung area where pulmonary vessels, bronchi, and ribs showed complex movements. The bone suppression technique improved tracking accuracy without special equipment and implantation of fiducial markers, and with only additional small dose to the patient. Bone suppression fluoroscopy is a potential measure for respiratory displacement of the target. This paper was presented at RSNA 2013 and was carried out at Kanazawa University, JAPAN.
Thaden, Jeremy J; Sanon, Saurabh; Geske, Jeffrey B; Eleid, Mackram F; Nijhof, Niels; Malouf, Joseph F; Rihal, Charanjit S; Bruce, Charles J
2016-06-01
There has been significant growth in the volume and complexity of percutaneous structural heart procedures in the past decade. Increasing procedural complexity and accompanying reliance on multimodality imaging have fueled the development of fusion imaging to facilitate procedural guidance. The first clinically available system capable of echocardiographic and fluoroscopic fusion for real-time guidance of structural heart procedures was approved by the US Food and Drug Administration in 2012. Echocardiographic-fluoroscopic fusion imaging combines the precise catheter and device visualization of fluoroscopy with the soft tissue anatomy and color flow Doppler information afforded by echocardiography in a single image. This allows the interventionalist to perform precise catheter manipulations under fluoroscopy guidance while visualizing critical tissue anatomy provided by echocardiography. However, there are few data available addressing this technology's strengths and limitations in routine clinical practice. The authors provide a critical review of currently available echocardiographic-fluoroscopic fusion imaging for guidance of structural heart interventions to highlight its strengths, limitations, and potential clinical applications and to guide further research into value of this emerging technology. Copyright © 2016 American Society of Echocardiography. Published by Elsevier Inc. All rights reserved.
2018-04-11
Cognitive Side Effects of Cancer Therapy; Malignant Ovarian Epithelial Tumor; Ovarian Brenner Tumor; Ovarian Carcinosarcoma; Ovarian Choriocarcinoma; Ovarian Clear Cell Cystadenocarcinoma; Ovarian Dysgerminoma; Ovarian Embryonal Carcinoma; Ovarian Endometrioid Adenocarcinoma; Ovarian Mixed Germ Cell Tumor; Ovarian Mucinous Cystadenocarcinoma; Ovarian Polyembryoma; Ovarian Sarcoma; Ovarian Seromucinous Carcinoma; Ovarian Serous Cystadenocarcinoma; Ovarian Teratoma; Ovarian Yolk Sac Tumor; Stage I Ovarian Cancer; Stage IA Fallopian Tube Cancer; Stage IA Ovarian Cancer; Stage IA Ovarian Germ Cell Tumor; Stage IB Fallopian Tube Cancer; Stage IB Ovarian Cancer; Stage IB Ovarian Germ Cell Tumor; Stage IC Fallopian Tube Cancer; Stage IC Ovarian Cancer; Stage IC Ovarian Germ Cell Tumor; Stage II Ovarian Cancer; Stage IIA Fallopian Tube Cancer; Stage IIA Ovarian Cancer; Stage IIA Ovarian Germ Cell Tumor; Stage IIB Fallopian Tube Cancer; Stage IIB Ovarian Cancer; Stage IIB Ovarian Germ Cell Tumor; Stage IIC Fallopian Tube Cancer; Stage IIC Ovarian Cancer; Stage IIC Ovarian Germ Cell Tumor; Stage IIIA Fallopian Tube Cancer; Stage IIIA Ovarian Cancer; Stage IIIA Ovarian Germ Cell Tumor; Stage IIIA Primary Peritoneal Cancer; Stage IIIB Fallopian Tube Cancer; Stage IIIB Ovarian Cancer; Stage IIIB Ovarian Germ Cell Tumor; Stage IIIB Primary Peritoneal Cancer; Stage IIIC Fallopian Tube Cancer; Stage IIIC Ovarian Cancer; Stage IIIC Ovarian Germ Cell Tumor; Stage IIIC Primary Peritoneal Cancer; Stage IV Fallopian Tube Cancer; Stage IV Ovarian Cancer; Stage IV Ovarian Germ Cell Tumor; Stage IV Primary Peritoneal Cancer; Undifferentiated Ovarian Carcinoma
2018-02-05
Cervical Adenosarcoma; Cervical Adenosquamous Carcinoma; Cervical Carcinosarcoma; Cervical Squamous Cell Carcinoma, Not Otherwise Specified; Endometrial Clear Cell Adenocarcinoma; Endometrial Endometrioid Adenocarcinoma; Endometrial Mixed Adenocarcinoma; Endometrial Mucinous Adenocarcinoma; Endometrial Squamous Cell Carcinoma; Endometrial Transitional Cell Carcinoma; Endometrial Undifferentiated Carcinoma; Fallopian Tube Adenocarcinoma; Fallopian Tube Clear Cell Adenocarcinoma; Fallopian Tube Mucinous Adenocarcinoma; Fallopian Tube Serous Adenocarcinoma; Fallopian Tube Transitional Cell Carcinoma; Malignant Ovarian Epithelial Tumor; Malignant Peritoneal Neoplasm; Ovarian Carcinosarcoma; Ovarian Clear Cell Adenocarcinoma; Ovarian Endometrioid Adenocarcinoma; Ovarian Mucinous Adenocarcinoma; Ovarian Serous Adenocarcinoma; Ovarian Transitional Cell Carcinoma; Primary Peritoneal Serous Adenocarcinoma; Recurrent Fallopian Tube Carcinoma; Recurrent Melanoma; Recurrent Ovarian Carcinoma; Recurrent Primary Peritoneal Carcinoma; Stage IV Skin Melanoma; Undifferentiated Fallopian Tube Carcinoma; Undifferentiated Ovarian Carcinoma; Uterine Corpus Carcinosarcoma
2018-06-11
BRCA Rearrangement; Deleterious BRCA1 Gene Mutation; Deleterious BRCA2 Gene Mutation; Fallopian Tube Clear Cell Adenocarcinoma; Fallopian Tube Transitional Cell Carcinoma; Ovarian Clear Cell Adenocarcinoma; Ovarian Endometrioid Tumor; Ovarian Seromucinous Carcinoma; Ovarian Serous Tumor; Ovarian Transitional Cell Carcinoma; Recurrent Fallopian Tube Carcinoma; Recurrent Ovarian Carcinoma; Recurrent Primary Peritoneal Carcinoma; Undifferentiated Fallopian Tube Carcinoma; Undifferentiated Ovarian Carcinoma
2017-01-05
Chemotherapeutic Agent Toxicity; Neuropathy; Neurotoxicity Syndrome; Pain; Stage IIIA Fallopian Tube Cancer; Stage IIIA Ovarian Cancer; Stage IIIA Primary Peritoneal Cancer; Stage IIIB Fallopian Tube Cancer; Stage IIIB Ovarian Cancer; Stage IIIB Primary Peritoneal Cancer; Stage IIIC Fallopian Tube Cancer; Stage IIIC Ovarian Cancer; Stage IIIC Primary Peritoneal Cancer; Stage IV Fallopian Tube Cancer; Stage IV Ovarian Cancer; Stage IV Primary Peritoneal Cancer
Kim, Dongkue; Park, Sangsoo; Jeong, Myung Ho; Ryu, Jeha
2018-02-01
In percutaneous coronary intervention (PCI), cardiologists must study two different X-ray image sources: a fluoroscopic image and an angiogram. Manipulating a guidewire while alternately monitoring the two separate images on separate screens requires a deep understanding of the anatomy of coronary vessels and substantial training. We propose 2D/2D spatiotemporal image registration of the two images in a single image in order to provide cardiologists with enhanced visual guidance in PCI. The proposed 2D/2D spatiotemporal registration method uses a cross-correlation of two ECG series in each image to temporally synchronize two separate images and register an angiographic image onto the fluoroscopic image. A guidewire centerline is then extracted from the fluoroscopic image in real time, and the alignment of the centerline with vessel outlines of the chosen angiographic image is optimized using the iterative closest point algorithm for spatial registration. A proof-of-concept evaluation with a phantom coronary vessel model with engineering students showed an error reduction rate greater than 74% on wrong insertion to nontarget branches compared to the non-registration method and more than 47% reduction in the task completion time in performing guidewire manipulation for very difficult tasks. Evaluation with a small number of experienced doctors shows a potentially significant reduction in both task completion time and error rate for difficult tasks. The total registration time with real procedure X-ray (angiographic and fluoroscopic) images takes [Formula: see text] 60 ms, which is within the fluoroscopic image acquisition rate of 15 Hz. By providing cardiologists with better visual guidance in PCI, the proposed spatiotemporal image registration method is shown to be useful in advancing the guidewire to the coronary vessel branches, especially those difficult to insert into.
2018-06-18
Deleterious BRCA1 Gene Mutation; Deleterious BRCA2 Gene Mutation; Fallopian Tube Endometrioid Adenocarcinoma; Fallopian Tube Serous Adenocarcinoma; High Grade Ovarian Serous Adenocarcinoma; Ovarian Endometrioid Tumor; Primary Peritoneal Serous Adenocarcinoma; Recurrent Fallopian Tube Carcinoma; Recurrent Ovarian Carcinoma; Recurrent Primary Peritoneal Carcinoma
DOE Office of Scientific and Technical Information (OSTI.GOV)
Damilakis, J; Perisinakis, K; Solomou, G
Purpose: The aim of this method was to provide dosimetric data on conceptus dose for the pregnant employee who participates in fluoroscopically-guided interventional procedures. Methods: Scattered air-kerma dose rates were obtained for 17 fluoroscopic projections involved in interventional procedures. These projections were simulated on an anthropomorphic phantom placed on the examination table supine. The operating theater was divided into two grids relative to the long table sides. Each grid consisted of 33 cells spaced 0.50 m apart. During the simulated exposures, at each cell, scatter air-kerma rate was measured at 110 cm from the floor i.e. at the height ofmore » the waist of the pregnant worker. Air-kerma rates were divided by the dose area product (DAP) rate of each exposure to obtain normalized data. For each projection, measurements were performed for 3 kVp and 3 filtration values i.e. for 9 different x-ray spectra. All measurements were performed by using a modern C-arm angiographic system (Siemens Axiom Artis, Siemens, Germany) and a radiation meter equipped with an ionization chamber. Results: The results consist of 153 iso-dose maps, which show the spatial distribution of DAP-normalized scattered air-kerma doses at the waist level of a pregnant worker. Conceptus dose estimation is possible using air-kerma to embryo/fetal dose conversion coefficients published in a previous study (J Cardiovasc Electrophysiol, Vol. 16, pp. 1–8, July 2005). Using these maps, occupationally exposed pregnant personnel may select a working position for a certain projection that keeps abdominal dose as low as reasonably achievable. Taking into consideration the regulatory conceptus dose limit for occupational exposure, determination of the maximum workload allowed for the pregnant personnel is also possible. Conclusion: Data produced in this work allow for the anticipation of conceptus dose and the determination of the maximum workload for a pregnant worker from any fluoroscopically-guided interventional procedure. This study was supported by the Greek Ministry of Education and Religious Affairs, General Secretariat for Research and Technology, Operational Program ‘Education and Lifelong Learning’, ARISTIA (Research project: CONCERT)« less
2018-04-26
Recurrent Uterine Corpus Cancer; Recurrent Fallopian Tube Cancer; Recurrent Ovarian Cancer; Recurrent Primary Peritoneal Cancer; Stage IIIA Uterine Corpus Cancer; Stage IIIA Fallopian Tube Cancer; Stage IIIA Ovarian Cancer; Stage IIIA Primary Peritoneal Cavity Cancer; Stage IIIB Uterine Corpus Cancer; Stage IIIB Fallopian Tube Cancer; Stage IIIB Ovarian Cancer; Stage IIIB Primary Peritoneal Cavity Cancer; Stage IIIC Uterine Corpus Cancer; Stage IIIC Fallopian Tube Cancer; Stage IIIC Ovarian Cancer; Stage IIIC Primary Peritoneal Cavity Cancer; Stage IV Fallopian Tube Cancer; Stage IV Ovarian Cancer; Stage IV Primary Peritoneal Cavity Cancer; Stage IVA Uterine Corpus Cancer; Stage IVB Uterine Corpus Cancer
Right ventricular septal pacing: the success of stylet-driven active-fixation leads.
Rosso, Raphael; Teh, Andrew W; Medi, Caroline; Hung, Thuy To; Balasubramaniam, Richard; Mond, Harry G
2010-01-01
The detrimental effects of right ventricular (RV) apical pacing on left ventricular function has driven interest in alternative pacing sites and in particular the mid RV septum and RV outflow tract (RVOT). RV septal lead positioning can be successfully achieved with a specifically shaped stylet and confirmed by the left anterior oblique (LAO) fluoroscopic projection. Such a projection is neither always used nor available during pacemaker implantation. The aim of this study was to evaluate how effective is the stylet-driven technique in septal lead placement guided only by posterior-anterior (PA) fluoroscopic view. One hundred consecutive patients with an indication for single- or dual-chamber pacing were enrolled. RV septal lead positioning was attempted in the PA projection only and confirmed by the LAO projection at the end of the procedure. The RV lead position was septal in 90% of the patients. This included mid RV in 56 and RVOT in 34 patients. There were no significant differences in the mean stimulation threshold, R-wave sensing, and lead impedance between the two sites.In the RVOT, 97% (34/35) of leads were placed on the septum, whereas in the mid RV the value was 89% (56/63). The study confirms that conventional active-fixation pacing leads can be successfully and safely deployed onto the RV septum using a purposely-shaped stylet guided only by the PA fluoroscopic projection.
2018-04-27
Fallopian Tube Transitional Cell Carcinoma; Malignant Ovarian Clear Cell Tumor; Malignant Ovarian Endometrioid Tumor; Malignant Ovarian Serous Tumor; Ovarian Seromucinous Carcinoma; Ovarian Transitional Cell Carcinoma; Primary Peritoneal Serous Adenocarcinoma; Recurrent Fallopian Tube Carcinoma; Recurrent Ovarian Carcinoma; Recurrent Primary Peritoneal Carcinoma; Undifferentiated Fallopian Tube Carcinoma; Undifferentiated Ovarian Carcinoma
Ultrasound-guided suprascapular nerve block: a correlation with fluoroscopic and cadaveric findings.
Peng, Philip W H; Wiley, Michael J; Liang, James; Bellingham, Geoff A
2010-02-01
Previous work on the ultrasound-guided injection technique and the sonoanatomy of the suprascapular region relevant to the suprascapular nerve (SSN) block suggested that the ultrasound scan showed the presence of the suprascapular notch and transverse ligament. The intended target of the ultrasound-guided injection was the notch. The objective of this case report and the subsequent cadaver dissection findings is to reassess the interpretation of the ultrasound images when locating structures for SSN block. A 45-yr-old man with chronic shoulder pain received an ultrasound-guided SSN block using the suprascapular notch as the intended target. The position of the needle was verified by fluoroscopy, which showed the tip of the needle well outside the suprascapular notch. Similar ultrasound-guided SSN blocks were performed in two cadavers. Dissections were performed which showed that the needle tips were not at the suprascapular notch but, more accurately, were close to the SSN but at the floor of the suprascapular fossa between the suprascapular and spinoglenoid notch. Our fluoroscopic and cadaver dissection findings both suggest that the ultrasound image of the SSN block shown by the well-described technique is actually targeting the nerve on the floor of the suprascapular spine between the suprascapular and spinoglenoid notches rather than the suprascapular notch itself. The structure previously identified as the transverse ligament is actually the fascia layer of the supraspinatus muscle.
Song, Min; Song, Ho-Young; Kim, Jin Hyoung; Park, Jung-Hoon; Jung, Hwoon-Yong; Kim, Jong-Hoon; Kim, Sung-Bae
2011-09-01
To retrospectively evaluate the incidence, predictive factors, and interventional management of food impaction after expandable metallic stent placement in patients with obstruction of the esophagus or upper gastrointestinal tract caused by benign or malignant disease. Between March 1993 and March 2010, 1,360 patients (1,029 men, 331 women; age range, 21-89 y; mean age, 61 y) underwent fluoroscopically guided stent placement for dysphagia caused by esophageal or gastrointestinal tract strictures. Five types of covered expandable metal stents were used, including four types of esophageal stents (types A-D) and one type of gastroduodenal stent (type E), with types A, B, C, D, and E stents used in 180, 60, 90, 432, and 598 patients, respectively. Multivariate analysis was performed to evaluate factors predictive of food impaction. Food impaction occurred in 41 of 1,360 patients (3.0%). The food impaction rates for types A, B, C, D, and E stents were 0.6%, 1.7%, 1.1%, 3.2%, and 4.0%, respectively. Multivariate analysis showed that stent length was an independent predictor of food impaction (odds ratio, 0.839; P = .012). Of the 41 patients with food impaction, 23 underwent endoscopic management, 12 underwent fluoroscopically guided management, and six did not require management because impacted food spontaneously passed through the stent. The overall food impaction rate was 3.0%, with multiple logistic regression analysis showing that shorter stent length was the only significant predictor of food impaction. Food impaction can be managed by endoscopic or fluoroscopically guided removal or placement of a second stent. Copyright © 2011 SIR. Published by Elsevier Inc. All rights reserved.
Video-guided calibration of an augmented reality mobile C-arm.
Chen, Xin; Naik, Hemal; Wang, Lejing; Navab, Nassir; Fallavollita, Pascal
2014-11-01
The augmented reality (AR) fluoroscope augments an X-ray image by video and provides the surgeon with a real-time in situ overlay of the anatomy. The overlay alignment is crucial for diagnostic and intra-operative guidance, so precise calibration of the AR fluoroscope is required. The first and most complex step of the calibration procedure is the determination of the X-ray source position. Currently, this is achieved using a biplane phantom with movable metallic rings on its top layer and fixed X-ray opaque markers on its bottom layer. The metallic rings must be moved to positions where at least two pairs of rings and markers are isocentric in the X-ray image. The current "trial and error" calibration process currently requires acquisition of many X-ray images, a task that is both time consuming and radiation intensive. An improved process was developed and tested for C-arm calibration. Video guidance was used to drive the calibration procedure to minimize both X-ray exposure and the time involved. For this, a homography between X-ray and video images is estimated. This homography is valid for the plane at which the metallic rings are positioned and is employed to guide the calibration procedure. Eight users having varying calibration experience (i.e., 2 experts, 2 semi-experts, 4 novices) were asked to participate in the evaluation. The video-guided technique reduced the number of intra-operative X-ray calibration images by 89% and decreased the total time required by 59%. A video-based C-arm calibration method has been developed that improves the usability of the AR fluoroscope with a friendlier interface, reduced calibration time and clinically acceptable radiation doses.
PET Imaging of Ovarian Carcinoma With 18F-FSPG
2018-06-04
Stage IIIA Fallopian Tube Cancer; Stage IIIA Ovarian Cancer; Stage IIIA Primary Peritoneal Cancer; Stage IIIB Fallopian Tube Cancer; Stage IIIB Ovarian Cancer; Stage IIIB Primary Peritoneal Cancer; Stage IIIC Fallopian Tube Cancer; Stage IIIC Ovarian Cancer; Stage IIIC Primary Peritoneal Cancer; Stage IV Fallopian Tube Cancer; Stage IV Ovarian Cancer; Stage IV Primary Peritoneal Cancer
Morphologic three-dimensional scanning of fallopian tubes to assist ovarian cancer diagnosis
NASA Astrophysics Data System (ADS)
Madore, Wendy-Julie; De Montigny, Etienne; Deschênes, Andréanne; Benboujja, Fouzi; Leduc, Mikaël; Mes-Masson, Anne-Marie; Provencher, Diane M.; Rahimi, Kurosh; Boudoux, Caroline; Godbout, Nicolas
2017-07-01
The majority of high-grade serous ovarian cancers is now believed to originate in the fallopian tubes. Therefore, current practices include the pathological examination of excised fallopian tubes. Detection of tumors in the fallopian tubes using current clinical approaches remains difficult but is of critical importance to achieve accurate staging and diagnosis. Here, we present an intraoperative imaging system for the detection of human fallopian tube lesions. The system is based on optical coherence tomography (OCT) to access subepithelial tissue architecture. To demonstrate that OCT could identify lesions, we analyzed 180 OCT volumes taken from five different ovarian lesions and from healthy fallopian tubes, and compared them to standard pathological review. We demonstrated that qualitative features could be matched to pathological conditions. We then determined the feasibility of intraluminal imaging of intact human fallopian tubes by building a dedicated endoscopic single-fiber OCT probe to access the mucosal layer inside freshly excised specimens from five patients undergoing prophylactic surgeries. The probe insertion into the lumen acquired images over the entire length of the tubes without damaging the mucosa, providing the first OCT images of intact human fallopian tubes.
van Duren, B H; Sugand, K; Wescott, R; Carrington, R; Hart, A
2018-05-01
Hip fractures contribute to a significant clinical burden globally with over 1.6 million cases per annum and up to 30% mortality rate within the first year. Insertion of a dynamic hip screw (DHS) is a frequently performed procedure to treat extracapsular neck of femur fractures. Poorly performed DHS fixation of extracapsular neck of femur fractures can result in poor mobilisation, chronic pain, and increased cut-out rate requiring revision surgery. A realistic, affordable, and portable fluoroscopic simulation system can improve performance metrics in trainees, including the tip-apex distance (the only clinically validated outcome), and improve outcomes. We developed a digital fluoroscopic imaging simulator using orthogonal cameras to track coloured markers attached to the guide-wire which created a virtual overlay on fluoroscopic images of the hip. To test the accuracy with which the augmented reality system could track a guide-wire, a standard workshop femur was used to calibrate the system with a positional marker fixed to indicate the apex; this allowed for comparison between guide-wire tip-apex distance (TAD) calculated by the system to be compared to that physically measured. Tests were undertaken to determine: (1) how well the apex could be targeted; (2) the accuracy of the calculated TAD. (3) The number of iterations through the algorithm giving the optimal accuracy-time relationship. The calculated TAD was found to have an average root mean square error of 4.2 mm. The accuracy of the algorithm was shown to increase with the number of iterations up to 20 beyond which the error asymptotically converged to an error of 2 mm. This work demonstrates a novel augmented reality simulation of guide-wire insertion in DHS surgery. To our knowledge this has not been previously achieved. In contrast to virtual reality, augmented reality is able to simulate fluoroscopy while allowing the trainee to interact with real instrumentation and performing the procedure on workshop bone models. Copyright © 2018 IPEM. Published by Elsevier Ltd. All rights reserved.
Navigation for fluoroscopy-guided cryo-balloon ablation procedures of atrial fibrillation
NASA Astrophysics Data System (ADS)
Bourier, Felix; Brost, Alexander; Kleinoeder, Andreas; Kurzendorfer, Tanja; Koch, Martin; Kiraly, Attila; Schneider, Hans-Juergen; Hornegger, Joachim; Strobel, Norbert; Kurzidim, Klaus
2012-02-01
Atrial fibrillation (AFib), the most common arrhythmia, has been identified as a major cause of stroke. The current standard in interventional treatment of AFib is the pulmonary vein isolation (PVI). PVI is guided by fluoroscopy or non-fluoroscopic electro-anatomic mapping systems (EAMS). Either classic point-to-point radio-frequency (RF)- catheter ablation or so-called single-shot-devices like cryo-balloons are used to achieve electrically isolation of the pulmonary veins and the left atrium (LA). Fluoroscopy-based systems render overlay images from pre-operative 3-D data sets which are then merged with fluoroscopic imaging, thereby adding detailed 3-D information to conventional fluoroscopy. EAMS provide tracking and visualization of RF catheters by means of electro-magnetic tracking. Unfortunately, current navigation systems, fluoroscopy-based or EAMS, do not provide tools to localize and visualize single shot devices like cryo-balloon catheters in 3-D. We present a prototype software for fluoroscopy-guided ablation procedures that is capable of superimposing 3-D datasets as well as reconstructing cyro-balloon catheters in 3-D. The 3-D cyro-balloon reconstruction was evaluated on 9 clinical data sets, yielded a reprojected 2-D error of 1.72 mm +/- 1.02 mm.
Clinical observation of fallopian tube obstruction recanalization by ozone
Sun, Niuniu; Wei, Lequn; Chen, Diansen; Gao, Wanqin; Niu, Huanzhang; He, Chao
2017-01-01
Objective: To investigate the clinical effect of fallopian tube obstruction recanalization by ozone. Methods: Total 116 cases of patients undergoing the fallopian tube obstruction were randomly divided into the experimental group and control group, with 58 cases in each group. All patients underwent the interventional fallopian tube recanalization. The patients in the experimental group underwent the fallopian tube perfusion by the ozone water. Meanwhile, the patients in the control group were treated with the conventional anti-inflammatory and anti-adhesion drugs. After the follow-up visit for 6 months, the pregnancy rate and fallopian tube re-occlusion rate were counted and compared between the two groups. Meanwhile, the symptoms were evaluated and compared between the two groups after the operation for two weeks. Results: The success rate of fallopian tube recanalization was 93.1% (54/58), the pregnancy rate was 79.3% (46/58) and the recurrence rate was 5.2% (3/58) in the experimental group. While the success rate of fallopian tube recanalization was 91.4% (53/58), the pregnancy rate was 60.3% (35/58) and the recurrence rate was 17.2% (10/58) in the control group. Analysis showed that there was no significant difference in the recanalization success rate between the two groups (P>0.05). However, the pregnancy rate and re-occlusion rate in the experimental group were significantly lower than those of the control group (P<0.05), and the difference was statistically significant. There was no significant difference in the discomfort symptoms between the experimental group and control group (P>0.05). Conclusion: Fallopian tube recanalization by ozone perfusion can effectively increase the postoperative pregnancy rate and reduce the fallopian tube re-occlusion. PMID:28523024
2018-04-17
Brenner Tumor; Malignant Ascites; Malignant Pleural Effusion; Ovarian Clear Cell Cystadenocarcinoma; Ovarian Endometrioid Adenocarcinoma; Ovarian Mixed Epithelial Carcinoma; Ovarian Serous Cystadenocarcinoma; Ovarian Undifferentiated Adenocarcinoma; Recurrent Fallopian Tube Cancer; Recurrent Ovarian Epithelial Cancer; Recurrent Ovarian Germ Cell Tumor; Recurrent Primary Peritoneal Cavity Cancer; Stage IIIA Fallopian Tube Cancer; Stage IIIA Ovarian Epithelial Cancer; Stage IIIA Ovarian Germ Cell Tumor; Stage IIIA Primary Peritoneal Cavity Cancer; Stage IIIB Fallopian Tube Cancer; Stage IIIB Ovarian Epithelial Cancer; Stage IIIB Ovarian Germ Cell Tumor; Stage IIIB Primary Peritoneal Cavity Cancer; Stage IIIC Fallopian Tube Cancer; Stage IIIC Ovarian Epithelial Cancer; Stage IIIC Ovarian Germ Cell Tumor; Stage IIIC Primary Peritoneal Cavity Cancer; Stage IV Fallopian Tube Cancer; Stage IV Ovarian Epithelial Cancer; Stage IV Ovarian Germ Cell Tumor; Stage IV Primary Peritoneal Cavity Cancer
Intravascular US-Guided Portal Vein Access: Improved Procedural Metrics during TIPS Creation.
Gipson, Matthew G; Smith, Mitchell T; Durham, Janette D; Brown, Anthony; Johnson, Thor; Ray, Charles E; Gupta, Rajan K; Kondo, Kimi L; Rochon, Paul J; Ryu, Robert K
2016-08-01
To evaluate transjugular intrahepatic portosystemic shunt (TIPS) outcomes and procedure metrics with the use of three different image guidance techniques for portal vein (PV) access during TIPS creation. A retrospective review of consecutive patients who underwent TIPS procedures for a range of indications during a 28-month study period identified a population of 68 patients. This was stratified by PV access techniques: fluoroscopic guidance with or without portography (n = 26), PV marker wire guidance (n = 18), or intravascular ultrasound (US) guidance (n = 24). Procedural outcomes and procedural metrics, including radiation exposure, contrast agent volume used, procedure duration, and PV access time, were analyzed. No differences in demographic or procedural characteristics were found among the three groups. Technical success, technical success of the primary planned approach, hemodynamic success, portosystemic gradient, and procedure-related complications were not significantly different among groups. Fluoroscopy time (P = .003), air kerma (P = .01), contrast agent volume (P = .003), and total procedural time (P = .02) were reduced with intravascular US guidance compared with fluoroscopic guidance. Fluoroscopy time (P = .01) and contrast agent volume (P = .02) were reduced with intravascular US guidance compared with marker wire guidance. Intravascular US guidance of PV access during TIPS creation not only facilitates successful TIPS creation in patients with challenging anatomy, as suggested by previous investigations, but also reduces important procedure metrics including radiation exposure, contrast agent volume, and overall procedure duration compared with fluoroscopically guided TIPS creation. Copyright © 2016 SIR. Published by Elsevier Inc. All rights reserved.
2018-04-26
High Grade Fallopian Tube Serous Adenocarcinoma; High Grade Ovarian Serous Adenocarcinoma; Primary Peritoneal High Grade Serous Adenocarcinoma; Recurrent Fallopian Tube Carcinoma; Recurrent Ovarian Carcinoma; Recurrent Primary Peritoneal Carcinoma
Mini access guide to simplify calyceal access during percutaneous nephrolithotomy: A novel device.
Chowdhury, Puskar Shyam; Nayak, Prasant; David, Deepak; Mallick, Sujata
2017-01-01
A precise puncture of the renal collecting system is the most essential step for percutaneous nephrolithotomy (PCNL). There are many techniques describing this crucial first step in PCNL including the bull's eye technique, triangulation technique, free-hand technique, and gradual descensus technique. We describe a novel puncture guide to assist accurate percutaneous needle placement during bull's eye technique. The mini access guide (MAG) stabilizes the initial puncture needle by mounting it on an adjustable multidirectional carrier fixed to the patient's skin, which aids in achieving the "bull's eye" puncture. It also avoids a direct fluoroscopic exposure of the urologist's hand during the puncture. Sixty consecutive patients with solitary renal calculus were randomized to traditional hand versus MAG puncture during bull's eye technique of puncture and the fluoroscopy time was assessed. The median fluoroscopy screening time for traditional free-hand bull's eye and MAG-guided bull's eye puncture (fluoroscopic screening time for puncture) was 55 versus 21 s ( P = 0.001) and the median time to puncture was 80 versus 55 s ( P = 0.052), respectively. Novice residents also learned puncture technique faster with MAG on simulator. The MAG is a simple, portable, cheap, and novel assistant to achieve successful PCNL puncture. It would be of great help for novices to establish access during their learning phase of PCNL. It would also be an asset toward significantly decreasing the radiation dose during PCNL access.
X-ray–free Ultrasound-guided Percutaneous Nephrolithotomy: How to Select the Right Patient?
Usawachintachit, Manint; Tzou, David T.; Hu, Weiguo; Li, Jianxing; Chi, Thomas
2017-01-01
OBJECTIVE To identify factors associated with successful ultrasound guidance for each surgical step of ultrasound-guided percutaneous nephrolithotomy (PCNL). PATIENTS AND METHODS Consecutive patients undergoing PCNL between March 2015 and June 2016 were prospectively enrolled. An attempt was made to use ultrasound guidance in renal access, tract dilation, and nephrostomy tube placement for each patient. For steps during which ultrasound guidance was unsuccessful, fluoroscopic screening was applied. Regression analysis identified patient characteristics associated with successful use of ultrasound guidance. RESULTS A total of 96 patients composed this cohort, with a mean body mass index of 28.7 kg/m2. Mean stone size was 33.1 ± 18.9 mm, and no hydronephrosis was found in 63.5% of cases. Fluoroscopic screening was required for renal access in 27 cases (28.1%), tract dilation in 38 (39.6%), and nephrostomy tube placement in 80 (83.3%). Multivariate analysis demonstrated that successful ultrasound guidance was significantly associated with the presence of hydronephrosis for renal access and the absence of staghorn calculi for tract dilation. Ultrasound-guided nephrostomy tube placement appeared linked to surgeon experience. CONCLUSION To achieve completely x-ray–free ultrasound-guided PCNL, the ideal patient should have a hydronephrotic collecting system with no staghorn stone present. For practitioners looking to adopt ultrasound guidance into their PCNL practice, these represent the most appropriate patients to safely initiate a surgical experience. PMID:27720776
Sensor-Based Electromagnetic Navigation (Mediguide®): How Accurate Is It? A Phantom Model Study.
Bourier, Felix; Reents, Tilko; Ammar-Busch, Sonia; Buiatti, Alessandra; Grebmer, Christian; Telishevska, Marta; Brkic, Amir; Semmler, Verena; Lennerz, Carsten; Kaess, Bernhard; Kottmaier, Marc; Kolb, Christof; Deisenhofer, Isabel; Hessling, Gabriele
2015-10-01
Data about localization reproducibility as well as spatial and visual accuracy of the new MediGuide® sensor-based electroanatomic navigation technology are scarce. We therefore sought to quantify these parameters based on phantom experiments. A realistic heart phantom was generated in a 3D-Printer. A CT scan was performed on the phantom. The phantom itself served as ground-truth reference to ensure exact and reproducible catheter placement. A MediGuide® catheter was repeatedly tagged at selected positions to assess accuracy of point localization. The catheter was also used to acquire a MediGuide®-scaled geometry in the EnSite Velocity® electroanatomic mapping system. The acquired geometries (MediGuide®-scaled and EnSite Velocity®-scaled) were compared to a CT segmentation of the phantom to quantify concordance. Distances between landmarks were measured in the EnSite Velocity®- and MediGuide®-scaled geometry and the CT dataset for Bland-Altman comparison. The visualization of virtual MediGuide® catheter tips was compared to their corresponding representation on fluoroscopic cine-loops. Point localization accuracy was 0.5 ± 0.3 mm for MediGuide® and 1.4 ± 0.7 mm for EnSite Velocity®. The 3D accuracy of the geometries was 1.1 ± 1.4 mm (MediGuide®-scaled) and 3.2 ± 1.6 mm (not MediGuide®-scaled). The offset between virtual MediGuide® catheter visualization and catheter representation on corresponding fluoroscopic cine-loops was 0.4 ± 0.1 mm. The MediGuide® system shows a very high level of accuracy regarding localization reproducibility as well as spatial and visual accuracy, which can be ascribed to the magnetic field localization technology. The observed offsets between the geometry visualization and the real phantom are below a clinically relevant threshold. © 2015 Wiley Periodicals, Inc.
C-arm cone beam computed tomography needle path overlay for fluoroscopic guided vertebroplasty.
Tam, Alda L; Mohamed, Ashraf; Pfister, Marcus; Chinndurai, Ponraj; Rohm, Esther; Hall, Andrew F; Wallace, Michael J
2010-05-01
Retrospective review. To report our early clinical experience using C-arm cone beam computed tomography (C-arm CBCT) with fluoroscopic overlay for needle guidance during vertebroplasty. C-arm CBCT is advanced three-dimensional (3-D) imaging technology that is currently available on state-of-the-art flat panel based angiography systems. The imaging information provided by C-arm CBCT allows for the acquisition and reconstruction of "CT-like" images in flat panel based angiography/interventional suites. As part of the evolution of this technology, enhancements allowing the overlay of cross-sectional imaging information can now be integrated with real time fluoroscopy. We report our early clinical experience with C-arm CBCT with fluoroscopic overlay for needle guidance during vertebroplasty. This is a retrospective review of 10 consecutive oncology patients who underwent vertebroplasty of 13 vertebral levels using C-arm CBCT with fluoroscopic overlay for needle guidance from November 2007 to December 2008. Procedural data including vertebral level, approach (transpedicular vs. extrapedicular), access (bilateral vs. unilateral) and complications were recorded. Technical success with the overlay technology was assessed based on accuracy which consisted of 4 measured parameters: distance from target to needle tip, distance from planned path to needle tip, distance from midline to needle tip, and distance from the anterior 1/3 of the vertebral body to needle tip. Success within each parameter required that the distance between the needle tip and parameter being evaluated be no more than 5 mm on multiplanar CBCT or fluoroscopy. Imaging data for 12 vertebral levels was available for review. All vertebral levels were treated using unilateral access and 9 levels were treated with an extrapedicular approach. Technical success rates were 92% for both distance from planned path and distance from midline to final needle tip, 100% when distance from needle tip to the anterior 1/3 border of the vertebral body was measured, and 75% when distance from target to needle tip was measured. There were no major complications. Minor complications consisted of 3 cases (25%) of cement extravasation. C-arm CBCT with needle path overlay for fluoroscopic guided vertebroplasty is feasible and allows for reliable unilateral therapy of both lumbar and thoracic vertebral bodies. Extrapedicular approaches were performed safely and with good accuracy of reaching the targets.
Fluoroscopically Guided Epidural Injections of the Cervical and Lumbar Spine.
Shim, Euddeum; Lee, Joon Woo; Lee, Eugene; Ahn, Joong Mo; Kang, Yusuhn; Kang, Heung Sik
2017-01-01
Advances in imaging and the development of injection techniques have enabled spinal intervention to become an important tool in managing chronic spinal pain. Epidural steroid injection (ESI) is one of the most widely used spinal interventions; it directly delivers drugs into the epidural space to relieve pain originating from degenerative spine disorders-central canal stenoses and neural foraminal stenoses-or disk herniations. Knowledge of the normal anatomy of the epidural space is essential to perform an effective and safe ESI and to recognize possible complications. Although computed tomographic (CT) or combined CT-fluoroscopic guidance has been increasingly used in ESI, conventional fluoroscopic guidance is generally performed. In ESI, drugs are delivered into the epidural space by interlaminar or transforaminal routes in the cervical spine or by interlaminar, transforaminal, or caudal routes in the lumbar spine. Epidurography is usually performed before drug delivery to verify the proper position of the needle in the epidural space. A small amount of contrast agent is injected with fluoroscopic guidance. Familiarity with the findings on a typical "true" epidurogram (demonstrating correct needle placement in the epidural space) permits proper performance of ESI. Findings on "false" epidurograms (demonstrating incorrect needle placement) include muscular staining and evidence of intravascular injection, inadvertent facet joint injection, dural puncture, subdural injection, and intraneural or intradiscal injection. © RSNA, 2016 An earlier incorrect version of this article appeared online. This article was corrected on December 22, 2016.
Cryo-balloon catheter localization in fluoroscopic images
NASA Astrophysics Data System (ADS)
Kurzendorfer, Tanja; Brost, Alexander; Jakob, Carolin; Mewes, Philip W.; Bourier, Felix; Koch, Martin; Kurzidim, Klaus; Hornegger, Joachim; Strobel, Norbert
2013-03-01
Minimally invasive catheter ablation has become the preferred treatment option for atrial fibrillation. Although the standard ablation procedure involves ablation points set by radio-frequency catheters, cryo-balloon catheters have even been reported to be more advantageous in certain cases. As electro-anatomical mapping systems do not support cryo-balloon ablation procedures, X-ray guidance is needed. However, current methods to provide support for cryo-balloon catheters in fluoroscopically guided ablation procedures rely heavily on manual user interaction. To improve this, we propose a first method for automatic cryo-balloon catheter localization in fluoroscopic images based on a blob detection algorithm. Our method is evaluated on 24 clinical images from 17 patients. The method successfully detected the cryoballoon in 22 out of 24 images, yielding a success rate of 91.6 %. The successful localization achieved an accuracy of 1.00 mm +/- 0.44 mm. Even though our methods currently fails in 8.4 % of the images available, it still offers a significant improvement over manual methods. Furthermore, detecting a landmark point along the cryo-balloon catheter can be a very important step for additional post-processing operations.
A practical guide for performing arthrography under fluoroscopic or ultrasound guidance.
Lungu, Eugen; Moser, Thomas P
2015-12-01
We propose a practical approach for performing arthrography with fluoroscopic or ultrasound guidance. Different approaches to the principal joints of the upper limb (shoulder, elbow, wrist and fingers), lower limb (hip, knee, ankle and foot) as well as the facet joints of the spine are discussed and illustrated with numerous drawings. Whenever possible, we emphasise the concept of targeting articular recesses, which offers many advantages over traditional techniques aiming at the joint space. • Arthrography remains a foremost technique in musculoskeletal radiology • Most joints can be successfully accessed by targeting the articular recess • Targeting the recess offers several advantages over traditional approaches • Ultrasound-guidance is now favoured over fluoroscopy and targeting the recess is equally applicable.
Shellikeri, Sphoorti; Setser, Randolph M; Hwang, Tiffany J; Srinivasan, Abhay; Krishnamurthy, Ganesh; Vatsky, Seth; Girard, Erin; Zhu, Xiaowei; Keller, Marc S; Cahill, Anne Marie
2017-07-01
Navigational software provides real-time fluoroscopic needle guidance for percutaneous procedures in the Interventional Radiology (IR) suite. We describe our experience with navigational software for pediatric percutaneous bone biopsies in the IR suite and compare technical success, diagnostic accuracy, radiation dose and procedure time with that of CT-guided biopsies. Pediatric bone biopsies performed using navigational software (Syngo iGuide, Siemens Healthcare) from 2011 to 2016 were prospectively included and anatomically matched CT-guided bone biopsies from 2008 to 2016 were retrospectively reviewed with institutional review board approval. C-arm CT protocols used for navigational software-assisted cases included institution-developed low-dose (0.1/0.17 μGy/projection), regular-dose (0.36 μGy/projection), or a combination of low-dose/regular-dose protocols. Estimated effective radiation dose and procedure times were compared between software-assisted and CT-guided biopsies. Twenty-six patients (15 male; mean age: 10 years) underwent software-assisted biopsies (15 pelvic, 7 lumbar and 4 lower extremity) and 33 patients (13 male; mean age: 9 years) underwent CT-guided biopsies (22 pelvic, 7 lumbar and 4 lower extremity). Both modality biopsies resulted in a 100% technical success rate. Twenty-five of 26 (96%) software-assisted and 29/33 (88%) CT-guided biopsies were diagnostic. Overall, the effective radiation dose was significantly lower in software-assisted than CT-guided cases (3.0±3.4 vs. 6.6±7.7 mSv, P=0.02). The effective dose difference was most dramatic in software-assisted cases using low-dose C-arm CT (1.2±1.8 vs. 6.6±7.7 mSv, P=0.001) or combined low-dose/regular-dose C-arm CT (1.9±2.4 vs. 6.6±7.7 mSv, P=0.04), whereas effective dose was comparable in software-assisted cases using regular-dose C-arm CT (6.0±3.5 vs. 6.6±7.7 mSv, P=0.7). Mean procedure time was significantly lower for software-assisted cases (91±54 vs. 141±68 min, P=0.005). In our experience, navigational software technology in the IR suite is a promising alternative to CT guidance for pediatric bone biopsies providing comparable technical success and diagnostic accuracy with lower radiation dose and procedure time, in addition to providing real-time fluoroscopic needle guidance.
Minimally Invasive Spinal Surgery with Intraoperative Image-Guided Navigation
Kim, Terrence T.; Johnson, J. Patrick; Pashman, Robert; Drazin, Doniel
2016-01-01
We present our perioperative minimally invasive spine surgery technique using intraoperative computed tomography image-guided navigation for the treatment of various lumbar spine pathologies. We present an illustrative case of a patient undergoing minimally invasive percutaneous posterior spinal fusion assisted by the O-arm system with navigation. We discuss the literature and the advantages of the technique over fluoroscopic imaging methods: lower occupational radiation exposure for operative room personnel, reduced need for postoperative imaging, and decreased revision rates. Most importantly, we demonstrate that use of intraoperative cone beam CT image-guided navigation has been reported to increase accuracy. PMID:27213152
Psychosexual Intervention in Patients With Stage I-III Gynecologic or Breast Cancer
2018-05-25
Ovarian Sarcoma; Ovarian Stromal Cancer; Stage I Uterine Sarcoma; Stage I Vaginal Cancer; Stage I Vulvar Cancer; Stage IA Cervical Cancer; Stage IA Endometrial Carcinoma; Stage IA Fallopian Tube Cancer; Stage IA Ovarian Epithelial Cancer; Stage IA Ovarian Germ Cell Tumor; Stage IA Primary Peritoneal Cavity Cancer; Stage IB Cervical Cancer; Stage IB Endometrial Carcinoma; Stage IB Fallopian Tube Cancer; Stage IB Ovarian Epithelial Cancer; Stage IB Ovarian Germ Cell Tumor; Stage IB Primary Peritoneal Cavity Cancer; Stage IC Fallopian Tube Cancer; Stage IC Ovarian Epithelial Cancer; Stage IC Ovarian Germ Cell Tumor; Stage IC Primary Peritoneal Cavity Cancer; Stage II Endometrial Carcinoma; Stage II Gestational Trophoblastic Tumor; Stage II Uterine Sarcoma; Stage II Vaginal Cancer; Stage II Vulvar Cancer; Stage IIA Cervical Cancer; Stage IIA Fallopian Tube Cancer; Stage IIA Ovarian Epithelial Cancer; Stage IIA Ovarian Germ Cell Tumor; Stage IIA Primary Peritoneal Cavity Cancer; Stage IIB Cervical Cancer; Stage IIB Fallopian Tube Cancer; Stage IIB Ovarian Epithelial Cancer; Stage IIB Ovarian Germ Cell Tumor; Stage IIB Primary Peritoneal Cavity Cancer; Stage IIC Fallopian Tube Cancer; Stage IIC Ovarian Epithelial Cancer; Stage IIC Ovarian Germ Cell Tumor; Stage IIC Primary Peritoneal Cavity Cancer; Stage III Gestational Trophoblastic Tumor; Stage III Uterine Sarcoma; Stage III Vaginal Cancer; Stage III Vulvar Cancer; Stage IIIA Cervical Cancer; Stage IIIA Endometrial Carcinoma; Stage IIIA Fallopian Tube Cancer; Stage IIIA Ovarian Epithelial Cancer; Stage IIIA Ovarian Germ Cell Tumor; Stage IIIA Primary Peritoneal Cavity Cancer; Stage IIIB Cervical Cancer; Stage IIIB Endometrial Carcinoma; Stage IIIB Fallopian Tube Cancer; Stage IIIB Ovarian Epithelial Cancer; Stage IIIB Ovarian Germ Cell Tumor; Stage IIIB Primary Peritoneal Cavity Cancer; Stage IIIC Endometrial Carcinoma; Stage IIIC Fallopian Tube Cancer; Stage IIIC Ovarian Epithelial Cancer; Stage IIIC Ovarian Germ Cell Tumor; Stage IIIC Primary Peritoneal Cavity Cancer; Breast Cancer
Esophageal stenosis in epidermolysis bullosum: a challenge for the endoscopist.
De Angelis, Paola; Caldaro, Tamara; Torroni, Filippo; Romeo, Erminia; Foschia, Francesca; di Abriola, Giovanni Federici; Rea, Francesca; El Hachem, May; Genovese, Elisabetta; D'Alessandro, Sandra; Dall'Oglio, Luigi
2011-05-01
Esophageal stenosis is a severe complication in dystrophic epidermolysis bullosa (EB). Endoscopic dilations may cause mucosal injury with stricture recurrence. Our aim was to describe our referral EB-center experience on safety and long-term efficacy of fluoroscopically guided balloon dilation without endoscopy. Over 14 years, 34 patients with EB, previously evaluated with barium esophagogram for dysphagia, underwent balloon esophageal dilation. Under fluoroscopy, a guide wire was introduced via a nostril into the stomach. A 12-mm pneumatic balloon, which passed over the wire, was filled using radio-opaque contrast, dilating the stricture. Orotracheal intubation was avoided. Antibiotics, dexamethasone, and proton-pump inhibitors were administered. Study approval was obtained from our ethical board. Ninety-three dilations were performed. Seventeen patients had a single stenosis. The mean age of onset was 18 years (range, 3-47 years). Thirteen patients underwent one dilation. In 6 cases, endoscopy was necessary to visualize the esophageal lumen. Complications included cervical esophageal perforation (2) and transitory dysphagia (10). Thirty patients were feeding within 24 hours. During the follow-up, 2 patients required a gastrostomy, and 2 patients underwent fundoplication for gastroesophageal reflux disease. Fluoroscopically guided balloon dilation in EB is a safe and well-tolerated procedure. An experienced endoscopy team is necessary in certain cases. Copyright © 2011 Elsevier Inc. All rights reserved.
Ovarian, Fallopian Tube, and Primary Peritoneal Cancer—Health Professional Version
Ovarian epithelial, fallopian tube, and peritoneal cancers are diseases in which malignant cells form in the tissue covering the ovary, lining the fallopian tube, or peritoneum. Find evidence-based information on ovarian cancer treatment, causes and prevention, screening, research, genetics and statistics.
Confocal microlaparoscope for imaging the fallopian tube
NASA Astrophysics Data System (ADS)
Wu, Tzu-Yu; Rouse, Andrew R.; Chambers, Setsuko K.; Hatch, Kenneth D.; Gmitro, Arthur F.
2014-11-01
Recent evidence suggests that ovarian cancer can originate in the fallopian tube. Unlike many other cancers, poor access to the ovary and fallopian tubes has limited the ability to study the progression of this deadly disease and to diagnosis it during the early stage when it is most amenable to therapy. A rigid confocal microlaparoscope system designed to image the epithelial surface of the ovary in vivo was previously reported. A new confocal microlaparoscope with an articulating distal tip has been developed to enable in vivo access to human fallopian tubes. The new microlaparoscope is compatible with 5-mm trocars and includes a 2.2-mm-diameter articulating distal tip consisting of a bare fiber bundle and an automated dye delivery system for fluorescence confocal imaging. This small articulating device should enable the confocal microlaparoscope to image early stage ovarian cancer arising inside the fallopian tube. Ex vivo images of animal tissue and human fallopian tube using the new articulating device are presented along with in vivo imaging results using the rigid confocal microlaparoscope system.
Martin, Colin J
2016-06-01
Doses to the eye lenses of clinicians undertaking fluoroscopically guided procedures can exceed the dose annual limit of 20 mSv, so optimisation of radiation protection is essential. Ceiling-suspended shields and disposable radiation absorbing pads can reduce eye dose by factors of 2-7. Lead glasses that shield against exposures from the side can lower doses by 2.5-4.5 times. Training in effective use of protective devices is an essential element in achieving good protection and acceptable eye doses. Effective methods for dose monitoring are required to identify protection issues. Dosemeters worn adjacent to the eye provide the better option for interventional clinicians, but an unprotected dosemeter worn at the neck will give an indication of eye dose that is adequate for most interventional staff. Potential requirements for protective devices and dose monitoring can be determined from risk assessments using generic values for dose linked to examination workload. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Greenbaum, Alissa; Parasher, Gulshan; Demarest, Gerald; Auyang, Edward
2017-05-05
Iatrogenic duodenal injury occurring during laparoscopic cholecystectomy (LC) is managed surgically, though rarely a large, persistent fistula is refractory to surgical interventions. We present the case of a 40-year-old woman transferred to our centre following elective LC for a reported perforated duodenal ulcer. An uncontained leak was found to originate from a 1.5 cm duodenal defect, with no evidence of ulceration. A duodenostomy tube was placed. One month after abdominal closure, the patient continued to have a persistent, large duodenal fistula. A through-the-scope covered oesophageal stent was placed under endoscopic and fluoroscopic guidance. Five weeks later, it was successfully retrieved and no subsequent extravasation of contrast from the duodenum was noted. Unrecognised iatrogenic duodenal injuries sustained during LC can be catastrophic. In cases of massive duodenal defects and high-output biliary fistula uncontrolled after surgical intervention, endoscopic-guided and fluoroscopic-guided placement of a fully covered oesophageal stent may be lifesaving. © BMJ Publishing Group Ltd (unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Morphologic 3D scanning of fallopian tubes to assist ovarian cancer diagnosis
NASA Astrophysics Data System (ADS)
Madore, Wendy-Julie; De Montigny, Etienne; Deschênes, Andréanne; Benboujja, Fouzi; Leduc, Mikael; Mes-Masson, Anne-Marie; Provencher, Diane M.; Rahimi, Kurosh; Boudoux, Caroline; Godbout, Nicolas
2016-02-01
Pathological evaluation of the fallopian tubes is an important diagnostic result but tumors can be missed using routine approaches. As the majority of high-grade serous ovarian cancers are now believed to originate in the fallopian tubes, pathological examination should include in a thorough examination of the excised ovaries and fallopian tubes. We present an dedicated imaging system for diagnostic exploration of human fallopian tubes. This system is based on optical coherence tomography (OCT), a laser imaging modality giving access to sub- epithelial tissue architecture. This system produces cross-sectional images up to 3 mm in depth, with a lateral resolution of ≍15μm and an axial resolution of ≍12μm. An endoscopic single fiber probe was developed to fit in a human fallopian tube. This 1.2 mm probe produces 3D volume data of the entire inner tube within a few minutes. To demonstrate the clinical potential of OCT for lesion identification, we studied 5 different ovarian lesions and healthy fallopian tubes. We imaged 52 paraffin-embedded human surgical specimens with a benchtop system and compared these images with histology slides. We also imaged and compared healthy oviducts from 3 animal models to find one resembling the human anatomy and to develop a functional ex vivo imaging procedure with the endoscopic probe. We also present an update on an ongoing clinical pilot study on women undergoing prophylactic or diagnostic surgery in which we image ex vivo fallopian tubes with the endoscopic probe.
Accuracy of ultrasound-guided nerve blocks of the cervical zygapophysial joints.
Siegenthaler, Andreas; Mlekusch, Sabine; Trelle, Sven; Schliessbach, Juerg; Curatolo, Michele; Eichenberger, Urs
2012-08-01
Cervical zygapophysial joint nerve blocks typically are performed with fluoroscopic needle guidance. Descriptions of ultrasound-guided block of these nerves are available, but only one small study compared ultrasound with fluoroscopy, and only for the third occipital nerve. To evaluate the potential usefulness of ultrasound-guidance in clinical practice, studies that determine the accuracy of this technique using a validated control are essential. The aim of this study was to determine the accuracy of ultrasound-guided nerve blocks of the cervical zygapophysial joints using fluoroscopy as control. Sixty volunteers were studied. Ultrasound-imaging was used to place the needle to the bony target of cervical zygapophysial joint nerve blocks. The levels of needle placement were determined randomly (three levels per volunteer). After ultrasound-guided needle placement and application of 0.2 ml contrast dye, fluoroscopic imaging was performed for later evaluation by a blinded pain physician and considered as gold standard. Raw agreement, chance-corrected agreement κ, and chance-independent agreement Φ between the ultrasound-guided placement and the assessment using fluoroscopy were calculated to quantify accuracy. One hundred eighty needles were placed in 60 volunteers. Raw agreement was 87% (95% CI 81-91%), κ was 0.74 (0.64-0.83), and Φ 0.99 (0.99-0.99). Accuracy varied significantly between the different cervical nerves: it was low for the C7 medial branch, whereas all other levels showed very good accuracy. Ultrasound-imaging is an accurate technique for performing cervical zygapophysial joint nerve blocks in volunteers, except for the medial branch blocks of C7.
Loughran, Brendan; Swetadri Vasan, S N; Singh, Vivek; Ionita, Ciprian N; Jain, Amit; Bednarek, Daniel R; Titus, Albert; Rudin, Stephen
2013-03-06
The detectors that are used for endovascular image-guided interventions (EIGI), particularly for neurovascular interventions, do not provide clinicians with adequate visualization to ensure the best possible treatment outcomes. Developing an improved x-ray imaging detector requires the determination of estimated clinical x-ray entrance exposures to the detector. The range of exposures to the detector in clinical studies was found for the three modes of operation: fluoroscopic mode, high frame-rate digital angiographic mode (HD fluoroscopic mode), and DSA mode. Using these estimated detector exposure ranges and available CMOS detector technical specifications, design requirements were developed to pursue a quantum limited, high resolution, dynamic x-ray detector based on a CMOS sensor with 50 μm pixel size. For the proposed MAF-CMOS, the estimated charge collected within the full exposure range was found to be within the estimated full well capacity of the pixels. Expected instrumentation noise for the proposed detector was estimated to be 50-1,300 electrons. Adding a gain stage such as a light image intensifier would minimize the effect of the estimated instrumentation noise on total image noise but may not be necessary to ensure quantum limited detector operation at low exposure levels. A recursive temporal filter may decrease the effective total noise by 2 to 3 times, allowing for the improved signal to noise ratios at the lowest estimated exposures despite consequent loss in temporal resolution. This work can serve as a guide for further development of dynamic x-ray imaging prototypes or improvements for existing dynamic x-ray imaging systems.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sutcliffe, James, E-mail: jasutcliffe@gmail.com; Wigham, Andrew, E-mail: a.wigham@doctors.org.uk; Mceniff, Niall, E-mail: nmceniff@stjames.ie
PurposeSurgical Gastrostomy has been around since the 19th century but in 1980 the first successful percutaneous endoscopic gastrostomy was reported. A year later the first successful percutaneous gastrostomy was performed using fluoroscopic guidance. The technique for percutaneous insertion and the equipment used has been refined since then and it is now considered the gold standard for gastrostomy insertion. Here we present guidelines for image-guided enteral feeding tubes in adults.Material and MethodWe performed a review and analysis of the scientific literature, other national and international guidelines and expert opinion.ResultsStudies have shown fluoroscopic techniques have consistently higher success rates with lower ratesmore » of major complications than endoscopic techniques. However, the Achilles' heel of many fluoroscopic techniques is the requirement for smaller gastrostomy tube sizes resulting in them being more prone to blockages and thus requiring further intervention.ConclusionRadiological feeding tube insertion is a safe and effective procedure. Success rates are higher, and complication rates lower than PEG or surgical gastrostomy tube placement and innovative techniques for gastric and jejunal access mean that there are very few cases in which RIG is not possible. The principal weakness of radiologically inserted gastrostomies is the limitiation on tube size which leads to a higher rate of tube blockage. Per-oral image-guided gastrostomies have to an extent addressed this but have not been popularised. Currently many centres still consider endoscopic gastrostomies as the first line unless patients are too unwell to undergo this procedure or previous attempts have failed, in which case radioloically inserted gastrostomies are the technique of choice.« less
ICHINOSE, Daisuke; TOCHIGI, Satoru; TANAKA, Toshihide; SUZUKI, Tomoya; TAKEI, Jun; HATANO, Keisuke; KAJIWARA, Ikki; MARUYAMA, Fumiaki; SAKAMOTO, Hiroki; HASEGAWA, Yuzuru; TANI, Satoshi; MURAYAMA, Yuichi
2018-01-01
A 40-year-old man presented with a severe headache, lower back pain, and lower abdominal pain 1 month after a head injury caused by falling. Computed tomography (CT) of the head demonstrated bilateral chronic subdural hematoma (CSDH) with a significant amount in the left frontoparietal region. At the same time, magnetic resonance imaging (MRI) of the lumbar spine also revealed CSDH from L2 to S1 level. A simple drainage for the intracranial CSDH on the left side was performed. Postoperatively, the headache was improved; however, the lower back and abdominal pain persisted. Aspiration of the liquefied spinal subdural hematoma was performed by a lumbar puncture under fluoroscopic guidance. The clinical symptoms were dramatically improved postoperatively. Concomitant intracranial and spinal CSDH is considerably rare so only 23 cases including the present case have been reported in the literature so far. The etiology and therapeutic strategy were discussed with a review of the literature. Therapeutic strategy is not established for these two concomitant lesions. Conservative follow-up was chosen for 14 cases, resulting in a favorable clinical outcome. Although surgical evacuation of lumbosacral CSDH was performed in seven cases, an alteration of cerebrospinal fluid (CSF) pressure following spinal surgery should be reminded because of the intracranial lesion. Since CSDH is well liquefied in both intracranial and spinal lesion, a less invasive approach is recommended not only for an intracranial lesion but also for spinal lesion. Fluoroscopic-guided lumbar puncture for lumbosacral CSDH following burr hole surgery for intracranial CSDH could be a recommended strategy. PMID:29479039
Kim, Hee Jin; Lee, Tae Won; Ihm, Chun Gyoo; Kim, Myung Jae
2002-01-01
Peritoneal catheter is the lifeline for the continuous ambulatory peritoneal dialysis (CAPD) patients. Over the years, obstruction or displacement of the CAPD catheter has been one of the common complications of CAPD. Fluoroscopy-guided wire manipulation or laparoscopic surgery has been developed to manage outflow obstruction. We analyzed the catheter outcome of fluoroscopy-guided wire manipulation or laparoscopic surgery to determine the ultimate benefit of these procedures. From June 1996 to August 2000, catheter complications were manipulated in 24 patients. Eleven (46%) of these patients were initially managed by guide wire under fluoroscopic control. The remaining 13 (54%) patients were manipulated by laparoscopic surgery. A successful outcome was defined as maintained normal peritoneal catheter function at 30 days after the manipulations. Among the catheters manipulated, 18 (75%) were inserted by nephrologist and 6 (25%) by surgeons at the initiation of CAPD. Tenckhoff double-cuff peritoneal catheters were inserted to all patients. The time elapsed between catheter insertion and manipulation varied from 1 to 60 days with a mean of 11 days. The primary causes of catheter malfunction were kinking in 1 case, omental wrapping with adhesions in 9 cases, and catheter displacements in the remaining 14 cases. Thirty-day catheter function was achieved in 50% (12/24) of initial catheter manipulations, with guide wire under fluoroscopic control (46%, 5/11) and laparoscopic surgery (54%, 7/13). Overall success rate of repeated manipulation was 71% (17 of 24). The successful outcome in repairing of the malfunctioning CAPD catheters could be increased by the combination of fluoroscopy-guided wire manipulation and laparoscopic surgery. Copyright 2002 S. Karger AG, Basel
Laparoscopic management of a fallopian tubal torsion complicated by a large hydrosalpinx
Lim, Wei How; Roex, Alphonse J
2011-01-01
Clinical presentation of an adnexal mass is often non-specific and may mimic a range of gynecological pathology, as well as renal or gastrointestinal causes of lower abdominal pain. While a common entity, its association with a fallopian tube pathology is very uncommon. Imaging such as ultrasound has been diagnostic in the evaluation of a pelvic mass, and has been reported as assisting the diagnosis of fallopian tubal torsion. A pelvic mass of cystic nature can be removed by cystectomy, while treatment options for a torted fallopian tube include surgical detorsion if detected early, or a salpingectomy should there be evidence of necrosis. We report a rare case of fallopian tube torsion complicated by a large hydrosalpinx which was managed by laparoscopic surgery. PMID:22140325
Collecting Tumor Samples From Patients With Gynecological Tumors
2016-10-26
Borderline Ovarian Clear Cell Tumor; Borderline Ovarian Serous Tumor; Cervical Adenocarcinoma; Cervical Adenosquamous Carcinoma; Cervical Small Cell Carcinoma; Cervical Squamous Cell Carcinoma, Not Otherwise Specified; Childhood Embryonal Rhabdomyosarcoma; Childhood Malignant Ovarian Germ Cell Tumor; Endometrioid Stromal Sarcoma; Gestational Trophoblastic Tumor; Malignant Mesothelioma; Malignant Ovarian Epithelial Tumor; Melanoma; Neoplasm of Uncertain Malignant Potential; Ovarian Brenner Tumor; Ovarian Clear Cell Cystadenocarcinoma; Ovarian Serous Cystadenocarcinoma; Paget Disease of the Vulva; Recurrent Cervical Carcinoma; Recurrent Fallopian Tube Carcinoma; Recurrent Ovarian Carcinoma; Recurrent Ovarian Germ Cell Tumor; Recurrent Primary Peritoneal Carcinoma; Recurrent Uterine Corpus Carcinoma; Recurrent Vaginal Carcinoma; Recurrent Vulvar Carcinoma; Stage I Ovarian Cancer; Stage I Uterine Corpus Cancer; Stage I Vaginal Cancer; Stage I Vulvar Cancer; Stage IA Cervical Cancer; Stage IA Fallopian Tube Cancer; Stage IA Ovarian Cancer; Stage IA Ovarian Germ Cell Tumor; Stage IB Cervical Cancer; Stage IB Fallopian Tube Cancer; Stage IB Ovarian Cancer; Stage IB Ovarian Germ Cell Tumor; Stage IC Fallopian Tube Cancer; Stage IC Ovarian Cancer; Stage IC Ovarian Germ Cell Tumor; Stage II Ovarian Cancer; Stage II Uterine Corpus Cancer; Stage II Vaginal Cancer; Stage II Vulvar Cancer; Stage IIA Cervical Cancer; Stage IIA Fallopian Tube Cancer; Stage IIA Ovarian Cancer; Stage IIA Ovarian Germ Cell Tumor; Stage IIB Cervical Cancer; Stage IIB Fallopian Tube Cancer; Stage IIB Ovarian Cancer; Stage IIB Ovarian Germ Cell Tumor; Stage IIC Fallopian Tube Cancer; Stage IIC Ovarian Cancer; Stage IIC Ovarian Germ Cell Tumor; Stage III Borderline Ovarian Surface Epithelial-Stromal Tumor; Stage III Cervical Cancer; Stage III Uterine Corpus Cancer; Stage III Vaginal Cancer; Stage III Vulvar Cancer; Stage IIIA Fallopian Tube Cancer; Stage IIIA Ovarian Cancer; Stage IIIA Ovarian Germ Cell Tumor; Stage IIIA Primary Peritoneal Cancer; Stage IIIB Fallopian Tube Cancer; Stage IIIB Ovarian Cancer; Stage IIIB Ovarian Germ Cell Tumor; Stage IIIB Primary Peritoneal Cancer; Stage IIIC Fallopian Tube Cancer; Stage IIIC Ovarian Cancer; Stage IIIC Ovarian Germ Cell Tumor; Stage IIIC Primary Peritoneal Cancer; Stage IV Borderline Ovarian Surface Epithelial-Stromal Tumor; Stage IV Fallopian Tube Cancer; Stage IV Ovarian Cancer; Stage IV Primary Peritoneal Cancer; Stage IV Uterine Corpus Cancer; Stage IVA Cervical Cancer; Stage IVA Vaginal Cancer; Stage IVB Cervical Cancer; Stage IVB Vaginal Cancer; Stage IVB Vulvar Cancer; Uterine Corpus Cancer; Uterine Corpus Leiomyosarcoma; Vulvar Squamous Cell Carcinoma
Giannakopoulos, Stilianos; Bantis, Athanasios; Kalaitzis, Christos; Touloupidis, Stavros
2010-10-01
Occasionally during percutaneous surgery, significant contrast extravasation obscures the field, making fluoroscopic access no longer feasible. Herein, we describe a salvage technique. The cystoscopically placed, open-end ureteral catheter is exchanged with an angled-tip angiographic catheter. With the aid of a guidewire and under fluoroscopic guidance, the tip of the catheter is placed in a posterior calix. The "bull's eye" technique is then applied to direct the needle into the tip of the catheter. This technique was used in four cases over a 7-year period. Successful access was accomplished in all cases through a middle or upper calix. The catheter serves as a target for providing access to the renal collecting system and facilitates final tract dilatation.
In vivo laser-based imaging of the human fallopian tube for future cancer detection
NASA Astrophysics Data System (ADS)
Seibel, Eric J.; Melville, C. David; Johnston, Richard S.; Gong, Yuanzheng; Agnew, Kathy; Chiang, Seine; Swisher, Elizabeth M.
2015-03-01
Inherited mutations in BRCA1 and BRCA2 lead to 20-50% lifetime risk of ovarian, tubal, or peritoneal carcinoma. Clinical recommendations for women with these genetic mutations include the prophylactic removal of ovaries and fallopian tubes by age 40 after child-bearing. Recent findings suggest that many presumed ovarian or peritoneal carcinomas arise in fallopian tube epithelium. Although survival rate is <90% when ovarian cancer is detected early (Stage_I), 70% of women have advanced disease (Stage_III/IV) at presentation when survival is less than 30%. Over the years, effective early detection of ovarian cancer has remained elusive, possibly because screening techniques have mistakenly focused on the ovary as origin of ovarian carcinoma. Unlike ovaries, the fallopian tubes are amenable to direct visual imaging without invasive surgery, using access through the cervix. To develop future screening protocols, we investigated using our 1.2- mm diameter, forward-viewing, scanning fiber endoscope (SFE) to image luminal surfaces of the fallopian tube before laparoscopic surgical removal. Three anesthetized human subjects participated in our protocol development which eventually led to 70-80% of the length of fallopian tubes being imaged in scanning reflectance, using red (632nm), green (532nm), and blue (442nm) laser light. A hysteroscope with saline uterine distention was used to locate the tubal ostia. To facilitate passage of the SFE through the interstitial portion of the fallopian tube, an introducer catheter was inserted 1- cm through each ostia. During insertion, saline was flushed to reduce friction and provide clearer viewing. This is likely the first high-resolution intraluminal visualization of fallopian tubes.
Precision of computer-assisted core decompression drilling of the knee.
Beckmann, J; Goetz, J; Bäthis, H; Kalteis, T; Grifka, J; Perlick, L
2006-06-01
Core decompression by exact drilling into the ischemic areas is the treatment of choice in early stages of osteonecrosis of the femoral condyle. Computer-aided surgery might enhance the precision of the drilling and lower the radiation exposure time of both staff and patients. The aim of this study was to evaluate the precision of the fluoroscopically based VectorVision-navigation system in an in vitro model. Thirty sawbones were prepared with a defect filled up with a radiopaque gypsum sphere mimicking the osteonecrosis. 20 sawbones were drilled by guidance of an intraoperative navigation system VectorVision (BrainLAB, Munich, Germany). Ten sawbones were drilled by fluoroscopic control only. A statistically significant difference with a mean distance of 0.58 mm in the navigated group and 0.98 mm in the control group regarding the distance to the desired mid-point of the lesion could be stated. Significant difference was further found in the number of drilling corrections as well as radiation time needed. The fluoroscopic-based VectorVision-navigation system shows a high feasibility and precision of computer-guided drilling with simultaneously reduction of radiation time and therefore could be integrated into clinical routine.
2018-05-14
Adult Glioblastoma; Endometrial Clear Cell Adenocarcinoma; Endometrial Serous Adenocarcinoma; Ovarian Clear Cell Cystadenocarcinoma; Ovarian Endometrioid Adenocarcinoma; Ovarian Mucinous Cystadenocarcinoma; Ovarian Serous Cystadenocarcinoma; Recurrent Fallopian Tube Carcinoma; Recurrent Ovarian Carcinoma; Recurrent Primary Peritoneal Carcinoma; Recurrent Uterine Corpus Carcinoma; Solid Neoplasm; Stage IIIA Fallopian Tube Cancer AJCC v7; Stage IIIA Ovarian Cancer AJCC v6 and v7; Stage IIIA Primary Peritoneal Cancer AJCC v7; Stage IIIB Fallopian Tube Cancer AJCC v7; Stage IIIB Ovarian Cancer AJCC v6 and v7; Stage IIIB Primary Peritoneal Cancer AJCC v7; Stage IIIC Fallopian Tube Cancer AJCC v7; Stage IIIC Ovarian Cancer AJCC v6 and v7; Stage IIIC Primary Peritoneal Cancer AJCC v7; Stage IV Fallopian Tube Cancer AJCC v6 and v7; Stage IV Ovarian Cancer AJCC v6 and v7; Stage IV Primary Peritoneal Cancer AJCC v7
NASA Astrophysics Data System (ADS)
Marshall, Emily L.; Borrego, David; Tran, Trung; Fudge, James C.; Bolch, Wesley E.
2018-03-01
Epidemiologic data demonstrate that pediatric patients face a higher relative risk of radiation induced cancers than their adult counterparts at equivalent exposures. Infants and children with congenital heart defects are a critical patient population exposed to ionizing radiation during life-saving procedures. These patients will likely incur numerous procedures throughout their lifespan, each time increasing their cumulative radiation absorbed dose. As continued improvements in long-term prognosis of congenital heart defect patients is achieved, a better understanding of organ radiation dose following treatment becomes increasingly vital. Dosimetry of these patients can be accomplished using Monte Carlo radiation transport simulations, coupled with modern anatomical patient models. The aim of this study was to evaluate the performance of the University of Florida/National Cancer Institute (UF/NCI) pediatric hybrid computational phantom library for organ dose assessment of patients that have undergone fluoroscopically guided cardiac catheterizations. In this study, two types of simulations were modeled. A dose assessment was performed on 29 patient-specific voxel phantoms (taken as representing the patient’s true anatomy), height/weight-matched hybrid library phantoms, and age-matched reference phantoms. Two exposure studies were conducted for each phantom type. First, a parametric study was constructed by the attending pediatric interventional cardiologist at the University of Florida to model the range of parameters seen clinically. Second, four clinical cardiac procedures were simulated based upon internal logfiles captured by a Toshiba Infinix-i Cardiac Bi-Plane fluoroscopic unit. Performance of the phantom library was quantified by computing both the percent difference in individual organ doses, as well as the organ dose root mean square values for overall phantom assessment between the matched phantoms (UF/NCI library or reference) and the patient-specific phantoms. The UF/NCI hybrid phantoms performed at percent differences of between 15% and 30% for the parametric set of irradiation events. Among internal logfile reconstructed procedures, the UF/NCI hybrid phantoms performed with RMS organ dose values between 7% and 29%. Percent improvement in organ dosimetry via the use of hybrid library phantoms over the reference phantoms ranged from 6.6% to 93%. The use of a hybrid phantom library, Monte Carlo radiation transport methods, and clinical information on irradiation events provide a means for tracking organ dose in these radiosensitive patients undergoing fluoroscopically guided cardiac procedures. This work was supported by Advanced Laboratory for Radiation Dosimetry Studies, University of Florida, American Association of University Women, National Cancer Institute Grant 1F31 CA159464.
NASA Astrophysics Data System (ADS)
Swetadri Vasan, S. N.; Pope, Liza; Ionita, Ciprian N.; Titus, A. H.; Bednarek, D. R.; Rudin, S.
2013-03-01
A novel dose reduction technique for fluoroscopic interventions involving a combination of a material x-ray region of interest (ROI) attenuator and spatially different, temporally variable ROI temporal recursive filter, was used to guide the catheter to the ROI in three live animal studies, two involving rabbits and one involving a sheep. In the two rabbit studies presented , a catheter was guided to the entrance of the carotid artery. With the added ROI attenuator the image under the high attenuation region is very noisy. By using temporal filtering with a filter weight of 0.6 on previous frames, the noise is reduced. In the sheep study the catheter was guided to the descending aorta of the animal. The sheep offered a relatively higher attenuation to the incident x-rays and thus a higher temporal filter weight of 0.8 on previous frames was used during the procedure to reduce the noise to levels acceptable by the interventionalist. The image sequences from both studies show that significant dose reduction of 5-6 times can be achieved with acceptable image quality outside the ROI by using the above mentioned technique. Even though the temporal filter weighting outside the ROI is higher, the consequent lag does not prevent perception of catheter movement.
Isolated torsion of fallopian tube in a post-menopausal patient: a case report.
Ozgun, Mahmut Tuncay; Batukan, Cem; Turkyilmaz, Cagdas; Serin, Ibrahim Serdar
2007-07-20
Isolated fallopian tube torsion after menopause is a rare condition. Here we report the second case of isolated fallopian tube torsion in a post-menopausal woman. A 55-year-old post-menopausal woman presented with right lower abdominal pain. Sonography depicted a simple cystic mass adjacent to the right uterine border. Laparatomy revealed torsion of the right fallopian tube together with a paraovarian cyst. Total abdominal hysterectomy and bilateral salpingo-oophorectomy was performed. Histopathological examination revealed a simple paraovarian cyst with severe congestion, necrosis and hemorrhage. Tubal torsion should be considered in the differential diagnosis of acute lower abdominal pain, even in post-menopausal women.
Imani, Farnad; Hemati, Karim; Rahimzadeh, Poupak; Kazemi, Mohamad Reza; Hejazian, Kokab
2016-01-01
Stellate Ganglion Block (SGB) is an effective technique which may be used to manage upper extremities pain due to Chronic Regional Pain Syndrome (CRPS), in this study we tried to evaluate the effectiveness of this procedure under two different guidance for management of this syndrome. The purpose of this study was to evaluate the effectiveness of ultrsound guide SGB by comparing it with the furoscopy guided SGB in upper extermities CRPS patients in reducing pain & dysfuction of the affected link. Fourteen patients with sympathetic CRPS in upper extremities in a randomized method with block randomization divided in two equal groups (with ultrasound or fluoroscopic guidance). First group was blocked under fluoroscopic guidance and second group blocked under ultrasound guidance. After correct positioning of the needle, a mixture of 5 ml bupivacaine 0.25% and 1 mL of triamcinolone was injected. These data represent no meaningful statistical difference between the two groups in terms of the number of pain attacks before the blocks, a borderline correlation between two groups one week and one month after the block and a significant statistical correlation between two groups three month after the block. These data represent no meaningful statistical difference between the patients of any group in terms of the pain intensity (from one week to six months after block), p-value = 0.61. These data represent a meaningful statistical difference among patients of any group and between the two groups in terms of the pain intensity (before the block until six months after block), p-values were 0.001, 0.031 respectively. According the above mentioned data, in comparison with fluoroscopic guidance, stellate ganglion block under ultrasound guidance is a safe and effective method with lower complication and better improvement in patient's disability indexes.
See, Jason; Amora, Jonah L; Lee, Sheldon; Lim, Paul; Teo, Wee Siong; Tan, Boon Yew; Ho, Kah Leng; Lee, Chee Wan; Ching, Chi-Keong
2016-07-01
The use of non-fluoroscopic systems (NFS) to guide radiofrequency catheter ablation (RFCA) for the treatment of supraventricular tachycardia (SVT) is associated with lower radiation exposure. This study aimed to determine if NFS reduces fluoroscopy time, radiation dose and procedure time. We prospectively enrolled patients undergoing RFCA for SVT. NFS included EnSiteTM NavXTM or CARTO® mapping. We compared procedure and fluoroscopy times, and radiation exposure between NFS and conventional fluoroscopy (CF) cohorts. Procedural success, complications and one-year success rates were reported. A total of 200 patients over 27 months were included and RFCA was guided by NFS for 79 patients; those with atrioventricular nodal reentrant tachycardia (AVNRT), left-sided atrioventricular reentrant tachycardia (AVRT) and right-sided AVRT were included (n = 101, 63 and 36, respectively). Fluoroscopy times were significantly lower with NFS than with CF (10.8 ± 11.1 minutes vs. 32.0 ± 27.5 minutes; p < 0.001). The mean fluoroscopic dose area product was also significantly reduced with NFS (NSF: 5,382 ± 5,768 mGy*cm2 vs. CF: 21,070 ± 23,311 mGy*cm2; p < 0.001); for all SVT subtypes. There was no significant reduction in procedure time, except for left-sided AVRT ablation (NFS: 79.2 minutes vs. CF: 116.4 minutes; p = 0.001). Procedural success rates were comparable (NFS: 97.5% vs. CF: 98.3%) and at one-year follow-up, there was no significant difference in the recurrence rates (NFS: 5.2% vs. CF: 4.2%). No clinically significant complications were observed in both groups. The use of NFS for RFCA for SVT is safe, with significantly reduced radiation dose and fluoroscopy time. Copyright © Singapore Medical Association.
Zhang, Fengxiang; Yang, Bing; Chen, Hongwu; Ju, Weizhu; Kojodjojo, Pipin; Cao, Kejiang; Chen, Minglong
2013-08-01
No randomized controlled study has prospectively compared the performance and clinical outcomes of remote magnetic control (RMC) vs manual catheter control (MCC) during ablation of right ventricular outflow tract (RVOT) ventricular premature complexes (VPC) or ventricular tachycardia (VT). The purpose of this study was to prospectively evaluate the efficacy and safety of using either RMC vs MCC for mapping and ablation of RVOT VPC/VT. Thirty consecutive patients with idiopathic RVOT VPC/VT were referred for catheter ablation and randomized into either the RMC or MCC group. A noncontact mapping system was deployed in the RVOT to identify origins of VPC/VT. Conventional activation and pace-mapping was performed to guide ablation. If ablation performed using 1 mode of catheter control was acutely unsuccessful, the patient crossed over to the other group. The primary endpoints were patients' and physicians' fluoroscopic exposure and times. Mean procedural times were similar between RMC and MCC groups. The fluoroscopic exposure and times for both patients and physicians were much lower in the RMC group than in the MCC group. Ablation was acutely successful in 14 of 15 patients in the MCC group and 10 of 15 in the RMC group. Following crossover, acute success was achieved in all patients. No major complications occurred in either group. During 22 months of follow-up, RVOT VPC recurred in 2 RMC patients. RMC navigation significantly reduces patients' and physicians' fluoroscopic times by 50.5% and 68.6%, respectively, when used in conjunction with a noncontact mapping system to guide ablation of RVOT VPC/VT. Copyright © 2013 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jones, A; Pasciak, A
Purpose: The purpose of this study was to determine if a relationship between indirect dose metrics and PSD could be established for fluoroscopically-guided interventional cardiology procedures. Methods: PSD were measured directly using XR-RV3 radiochromic film for 94 consecutive fluoroscopically guided interventional cardiology procedures performed at two sites. Procedures were both diagnostic and therapeutic in nature. Radiation dose structured reports (RDSR) were collected for each procedure and used to calculate indirect estimates of PSD which were compared to the measured PSD. Reference air kerma (Ka,r) was also compared to the measured PSD. Pearson’s correlation coefficient was calculated for each metric andmore » metrics were compared to measured PSD using a two-tailed t-test. Data were log transformed prior to statistical analysis. Results: Both Ka,r and the calculated PSD were closely correlated with measured PSD at each sites (Ka,r: 0.92 and 0.86, indirect PSD: 0.91 and 0.88). At one site, neither Ka,r nor indirect PSD was significantly different from the measured PSD (p = 0.22 and p=0.054, respectively), while at the second site both Ka,r and indirect PSD were significantly higher than measured PSD (p<0.0001 and p<0.0001, respectively). In almost all cases, both Ka,r and indirect PSD overestimated the true PSD. Conclusions: The use of a range of gantry angles and table positions, along with variation in procedural imaging requirements, limits the utility of indirect dose metrics for predicting PSD for interventional cardiology procedures. A. Kyle Jones and Alexander S. Pasciak are owners of Fluoroscopic Safety, LLC.« less
X-ray and optical stereo-based 3D sensor fusion system for image-guided neurosurgery.
Kim, Duk Nyeon; Chae, You Seong; Kim, Min Young
2016-04-01
In neurosurgery, an image-guided operation is performed to confirm that the surgical instruments reach the exact lesion position. Among the multiple imaging modalities, an X-ray fluoroscope mounted on C- or O-arm is widely used for monitoring the position of surgical instruments and the target position of the patient. However, frequently used fluoroscopy can result in relatively high radiation doses, particularly for complex interventional procedures. The proposed system can reduce radiation exposure and provide the accurate three-dimensional (3D) position information of surgical instruments and the target position. X-ray and optical stereo vision systems have been proposed for the C- or O-arm. Two subsystems have same optical axis and are calibrated simultaneously. This provides easy augmentation of the camera image and the X-ray image. Further, the 3D measurement of both systems can be defined in a common coordinate space. The proposed dual stereoscopic imaging system is designed and implemented for mounting on an O-arm. The calibration error of the 3D coordinates of the optical stereo and X-ray stereo is within 0.1 mm in terms of the mean and the standard deviation. Further, image augmentation with the camera image and the X-ray image using an artificial skull phantom is achieved. As the developed dual stereoscopic imaging system provides 3D coordinates of the point of interest in both optical images and fluoroscopic images, it can be used by surgeons to confirm the position of surgical instruments in a 3D space with minimum radiation exposure and to verify whether the instruments reach the surgical target observed in fluoroscopic images.
NASA Astrophysics Data System (ADS)
Liu, Wen P.; Armand, Mehran; Otake, Yoshito; Taylor, Russell H.
2011-03-01
Percutaneous femoroplasty [1], or femoral bone augmentation, is a prospective alternative treatment for reducing the risk of fracture in patients with severe osteoporosis. We are developing a surgical robotics system that will assist orthopaedic surgeons in planning and performing a patient-specific, augmentation of the femur with bone cement. This collaborative project, sponsored by the National Institutes of Health (NIH), has been the topic of previous publications [2],[3] from our group. This paper presents modifications to the pose recovery of a fluoroscope tracking (FTRAC) fiducial during our process of 2D/3D registration of X-ray intraoperative images to preoperative CT data. We show improved automata of the initial pose estimation as well as lower projection errors with the advent of a multiimage pose optimization step.
The value of physical examination in the diagnosis of hip osteoarthritis.
Chong, Timothy; Don, Darren W; Kao, Ming-Chih; Wong, Dexter; Mitra, Raj
2013-01-01
To compare the sensitivity of physical examination (internal rotation of the hip) with radiographs (using the Kellgren-Lawrence grading scale) in the diagnosis of clinically significant hip osteoarthritis. Case Series, Retrospective chart review of hip pain patients that underwent fluoroscopically guided hip steroid and anesthetic injections. 10 patients with hip pain patients seen at an academic outpatient center over a 2 year period were analyzed. Fluoroscopically guided hip steroid and anesthetic injection. Pain relief and change in VAS pain score after intra-articular hip steroid and lidocaine injection was the main outcome measure. Based on Fisher's exact test, there was no association between severity of radiographic hip arthritis and pain relief with intra-articular anesthetic/steroid injection (p=0.45). Physical examination (provocative hip internal rotation) however was associated with a significant decrease in VAS pain score after intra-articular lidocaine and corticosteroid hip injection (p=0.022). Simple hip radiographs alone are not sufficient to diagnose clinically significant hip osteoarthritis. Physical examination (hip internal rotation) was found to be more accurate than simple radiographs in the diagnosis of clinically significant hip osteoarthritis. Radiographs seem to best utilized when they are an extension of the physical examination and patient history.
2018-03-16
High Grade Ovarian Serous Adenocarcinoma; Ovarian Endometrioid Tumor; Recurrent Fallopian Tube Carcinoma; Recurrent Ovarian Carcinoma; Recurrent Primary Peritoneal Carcinoma; Stage IV Fallopian Tube Cancer AJCC v6 and v7; Stage IV Ovarian Cancer AJCC v6 and v7; Stage IV Primary Peritoneal Cancer AJCC v7
2016-07-22
Adult Solid Neoplasm; Estrogen Receptor Negative; Fallopian Tube Serous Neoplasm; HER2/Neu Negative; Ovarian Serous Adenocarcinoma; Ovarian Serous Tumor; Primary Peritoneal Serous Adenocarcinoma; Progesterone Receptor Negative; Recurrent Breast Carcinoma; Recurrent Fallopian Tube Carcinoma; Recurrent Ovarian Carcinoma; Recurrent Primary Peritoneal Carcinoma; Triple-Negative Breast Carcinoma
Toyoshima, Masafumi; Mori, Hikaru; Kudo, Kei; Yodogawa, Yuki; Sato, Kazuyo; Kudo, Takako; Igeta, Saori; Makino, Hiromitsu; Shima, Takashi; Matsuura, Rui; Ishigaki, Nobuko; Akagi, Kozo; Takeyama, Yoichi; Iwahashi, Hideki; Yoshinaga, Kosuke
2015-11-17
Isolated torsion of the fallopian tube without an ovarian abnormality is an uncommon event, with an incidence of approximately 1 in 1,500,000 females. Isolated torsion of the fallopian tube occurs mostly in reproductive-aged women, and is thus extremely rare in menopausal women and pre-pubertal girls. In case 1, 63-year-old Japanese woman presented with a 2-day history of acute lower abdominal pain. Menopause occurred at 53 years of age. Pelvic ultrasonography showed an enlarged mass (73 × 47 mm) on the right side of her uterus. An urgent laparoscopy was performed based on a presumptive diagnosis of right ovarian tumor torsion. During the laparoscopy, we noted a black, necrotic, solid tumor arising from the distal end of her right fimbria. Her right fallopian tube was twisted with the tumor, but her right ovary was normal and not involved. A laparoscopic tumorectomy with a right salpingectomy was performed. Her post-operative course was uneventful. In case 2, a 10-year-old Japanese girl presented with a 1-day history of lower abdominal pain associated with nausea and vomiting. Menarche had occurred 2 months earlier. A computed tomography and magnetic resonance imaging examination demonstrated a dilated tubal cystic mass with a normal uterus and bilateral ovaries. An urgent laparoscopy was performed based on a presumptive diagnosis of right fallopian tube torsion. During laparoscopy, her right fallopian tube was noted to be dark red, dilated, and twisted several times. Her right fimbria was necrotic-appearing and could not be preserved. Therefore, a laparoscopic right salpingectomy was performed. A histologic examination revealed ischemic changes with congestion of her right fallopian tube, which was consistent with tubal torsion. She had an uncomplicated post-operative course. We have presented two very rare cases of isolated fallopian tubal torsion. Radiologic interventions, such as computed tomography and magnetic resonance imaging, in addition to ultrasonography, are helpful diagnostic tools. Isolated torsion of the fallopian tube should be considered in the differential diagnosis of lower abdominal pain with a cystic mass and a normal ipsilateral ovary in all female patients, regardless of age.
X-ray beam equalization for digital fluoroscopy
NASA Astrophysics Data System (ADS)
Molloi, Sabee Y.; Tang, Jerry; Marcin, Martin R.; Zhou, Yifang; Anvar, Behzad
1996-04-01
The concept of radiographic equalization has previously been investigated. However, a suitable technique for digital fluoroscopic applications has not been developed. The previously reported scanning equalization techniques cannot be applied to fluoroscopic applications due to their exposure time limitations. On the other hand, area beam equalization techniques are more suited for digital fluoroscopic applications. The purpose of this study is to develop an x- ray beam equalization technique for digital fluoroscopic applications that will produce an equalized radiograph with minimal image artifacts and tube loading. Preliminary unequalized images of a humanoid chest phantom were acquired using a digital fluoroscopic system. Using this preliminary image as a guide, an 8 by 8 array of square pistons were used to generate masks in a mold with CeO2. The CeO2 attenuator thicknesses were calculated using the gray level information from the unequalized image. The generated mask was positioned close to the focal spot (magnification of 8.0) in order to minimize edge artifacts from the mask. The masks were generated manually in order to investigate the piston and matrix size requirements. The development of an automated version of mask generation and positioning is in progress. The results of manual mask generation and positioning show that it is possible to generate equalized radiographs with minimal perceptible artifacts. The equalization of x-ray transmission across the field exiting from the object significantly improved the image quality by preserving local contrast throughout the image. Furthermore, the reduction in dynamic range significantly reduced the effect of x-ray scatter and veiling glare from high transmission to low transmission areas. Also, the x-ray tube loading due to the mask assembly itself was negligible. In conclusion it is possible to produce area beam compensation that will be compatible with digital fluoroscopy with minimal compensation artifacts. The compensation process produces an image with equalized signal to noise ratio in all parts of the image.
Fiorella, David; Arthur, Adam; Schafer, Sebastian
2015-08-01
The Apollo system (Penumbra Inc, Alameda, California, USA) is a low profile irrigation-aspiration system designed for the evacuation of intracranial hemorrhage. To demonstrate the feasibility of using Apollo in combination with cone beam CT guidance. Parenchymal (n=1) and mixed parenchymal-intraventricular hematomas (n=1) were created in cadaver heads using a transvascular (n=1) or transcranial (n=1) approach. Hematomas were then imaged with cone beam CT (CB-CT), and the long axis of the hematoma defined. The CB-CT data were then used to guide transcranial access to the hematoma-defining the location of the burr hole and the path to the leading edge of the hematoma. An 8F vascular sheath was then placed under live fluoroscopic guidance into the hematoma. A second CB-CT was performed to confirm localization of the sheath. The hematoma was then demarcated on the CB-CT and the Apollo wand was introduced through the 8F sheath and irrigation-aspiration was performed under (periodic) live fluoroscopic guidance. The operators manipulated the wand within the visible boundaries of the hematoma. After irrigation-aspiration, a control CB-CT was performed to document reduction in hematoma volume. Transvascular and transcranial techniques were both successful in creating intracranial hematomas. Hematomas could be defined with conspicuity sufficient for localization and volumetric measurement using CB-CT. Live fluoroscopic guidance was effective in navigating a sheath into the leading aspect of a parenchymal hematoma and guiding irrigation-aspiration with the Apollo system. Irrigation-aspiration reduced the parenchymal hemorrhage volume from 14.8 to 1.7 cc in 189 s in the first case (parenchymal hemorrhage) and from 26.4 to 4.1 cc in 300 s in the second case (parenchymal and intraventricular hemorrhage). The cadaver model described is a useful means of studying interventional techniques for intracranial hemorrhage. It seems feasible to use CB-CT to guide the evacuation of intraparenchymal and intraventricular hemorrhage using the Apollo system through a minimally invasive transcranial access. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Kim, Juyoung; Park, Daehyun; Han, Won Bo; Jeong, Hyangjin; Park, Youngse
2014-07-01
Torsion of uterine adnexa is an important cause of acute abdominal pain in females. The main organ which can cause torsion is the ovaries, but torsions of the fallopian tube, subserosal myoma, paratubal cyst, and even the uterine body have been reported. The incidence of isolated fallopian tubal torsion is very rare. Even more rarely, it can coil around nearby organs such as the utero-ovarian ligament, showing similar clinical manifestations with those of adnexal torsion. We experienced an extremely rare case of acute abdomen induced by ovarian congestion triggered by the fallopian tube accompanying a paratubal cyst coiling around the utero-ovarian ligament. The right paratubal cyst was misinterpreted as being part of a cystic component of the left ovary on preoperative sonographic examination, and the coiling of the right fallopian tube accompanying the paratubal cyst was misdiagnosed as torsion of the right ovary. We report this rare case with a brief literature review.
Kim, Juyoung; Park, Daehyun; Han, Won Bo; Jeong, Hyangjin
2014-01-01
Torsion of uterine adnexa is an important cause of acute abdominal pain in females. The main organ which can cause torsion is the ovaries, but torsions of the fallopian tube, subserosal myoma, paratubal cyst, and even the uterine body have been reported. The incidence of isolated fallopian tubal torsion is very rare. Even more rarely, it can coil around nearby organs such as the utero-ovarian ligament, showing similar clinical manifestations with those of adnexal torsion. We experienced an extremely rare case of acute abdomen induced by ovarian congestion triggered by the fallopian tube accompanying a paratubal cyst coiling around the utero-ovarian ligament. The right paratubal cyst was misinterpreted as being part of a cystic component of the left ovary on preoperative sonographic examination, and the coiling of the right fallopian tube accompanying the paratubal cyst was misdiagnosed as torsion of the right ovary. We report this rare case with a brief literature review. PMID:25105111
Fluoroscopic Sacroiliac Joint Injection: Is Oblique Angulation Really Necessary?
Khuba, Sandeep; Agarwal, Anil; Gautam, Sujeet; Kumar, Sanjay
2016-01-01
The conventional technique for sacroiliac (SI) joint injection involves aligning the anterior and posterior aspects of the SI joint under fluoroscopic guidance and then entering the SI joint in the most caudal aspect. We wish to highlight that there is no added advantage to aligning both the anterior and posterior joint lines of the SI joint as it is time consuming, associated with additional radiation exposure, and may make the entry into the posterior SI joint technically more difficult. Observational study. Pain Clinic, Department of Anesthesiology. With the patient lying prone on fluoroscopy table, SI joint injection is performed with a 22 G, 10 cm spinal needle in a true anteroposterior (AP) view, where anterior and posterior SI joint spaces are seen as separate entities, where the medial joint space represents the posterior SI joint and the lateral joint space represents the anterior SI joint. The distal 1 cm of the medial joint space is entered under AP view. If the SI joint is seen as a straight line rather than 2 joint spaces in the AP view then the image intensifier of the fluoroscope was tilted cranially to elongate the image of the lower part of the posterior SI joint, thus facilitating entry into this part of the joint which was confirmed by administering 0.3 to 0.5 mL of radiopaque contrast medium. Sixty SI joints of 58 patients were injected under an AP fluoroscopic view. Forty-two (70%) SI joints were seen as 2 separate medial and lateral joint spaces and were entered in distal 1 cm of the medial joint space. In 18 (30%) joints seen as a straight line rather than 2 separate spaces, the image intensifier of the fluoroscope was tilted cranially to elongate the image of the lower part of the posterior SI joint and then the SI joint was entered in its distal 1 cm. Confirmation of entry into the SI joint was confirmed by with 0.3 to 0.5 mL of radiopaque contrast medium. In 4 cases the joints did not show the correct radiopaque contrast spread (3/42 and 1/18) although the needle seemed to be in the joint space. Small sample size. Aligning the anterior and posterior aspects of SI joint for fluoroscopic guided SI joint injection is not necessary for the success of the block.Key words: Sacroiliac joint, injection, anteroposterior view, oblique angulation, fluoroscopic technique.
The primary fallopian tube carcinoma: a rare association with pelvic nodal tuberculosis
Mamouni, Nisrine; Saadi, Hanane; belfatemi, Hinde; Erraghay, Sanaa; Bouchikhi, Chahrazade; Banani, Abdelaziz
2017-01-01
The primary carcinoma of fallopian tube is a rare entity. It represents 0.14 to 1.81% of genital cancers in women. It is a cancer of older women. Its association with tuberculosis is exceptional. We report a rare case of bilateral serous adenocarcinoma of the fallopian tube in a patient aged 42 years, multiparous, whose characteristic is the unexpected association with peritoneal tuberculosis. PMID:29541309
Chen, Chiu-Hua; Hsu, Che-Fang; Huang, Rui-Len; Ding, Dah-Ching; Chu, Tang-Yuan
2016-01-01
During human ovulation, the fallopian tube fimbriae must move to the ovulation site to catch the oocyte. As the tissue-of-origin of the majority of ovarian high-grade serous carcinoma (HGSC), the fallopian tube fimbriae carrying a precursor cancer lesion may also approach the ovulatory site for metastasis. We hypothesize that platelet-derived growth factor (PDGF) in mature follicle fluid (FF) attracts the migration of PDGFR-expressing fimbriae toward the ovulating follicle. We observed that more PDGFR-β was expressed in the distal part than in the proximal parts of the fallopian tube, particularly in stromal cells in the lamina propria. The stromal cells, but not the epithelial cells, from normal fimbriae and fallopian tube HGSC were highly chemotactic to mature FF. The chemotactic activities were positively correlated with PDGF-BB and estradiol levels in FF and were abolished by a blocking antibody of PDGFR-β and by tyrosine kinase inhibitor imatinib. When PDGF-BB/AB was depleted from the FF, more than 80% of chemotaxis activities were diminished. This study suggests an ovarian follicle-directed and PDGF-dependent attraction of fallopian tube fimbriae before ovulation. The same mechanism may also be crucial for the ovarian homing of HGSC, which largely originates in the fimbriae. PMID:27379403
NASA Astrophysics Data System (ADS)
Divakar, Prajan; Trembly, B. Stuart; Moodie, Karen L.; Hoopes, P. Jack; Wegst, Ulrike G. K.
2017-02-01
Recent failures in hysteroscopic female sterilization procedures have brought into question the implantation of nonresorbable metal devices into the fallopian tubes due to long-term risks such as migration, fragmentation, and tubal perforation. The goal of this study is to assess whether a porous, biodegradable implant can be deposited into the fallopian tube lumen with or without a local mild heat treatment to generate a safe and permanent fallopian tube occlusion/sterilization event. The technologies investigated included freeze-cast collagen-based scaffolds and magnetic nanoparticle (MNP) based scaffolds. In vitro assessment of iron oxide MNP-based scaffolds was performed to determine the absorption rate density (ARD); subsequent computational modeling quantified the thermal in vivo steady state temperature as a function of tubal radius for treatment planning. For collagen-based scaffolds, in vivo testing was performed to study the biocompatibility in a mouse flank model, followed by implantation into an in vivo anestrus feline uterine horn (animal model for the fallopian tube). Biological responses were studied histopathologically. Uterine horn patency was assessed via radiographic imaging. Preliminary studies suggest the MNP-impregnated scaffold and a safe, noninvasive AMF excitation field have potential to generate a sufficient focal fallopian tube thermal dose to create a fibrotic healing event and ultimately, permanent tubal occlusion.
Pauna, Henrique F.; Monsanto, Rafael C.; Schachern, Patricia A.; Costa, Sady S.; Kwon, Geeyoun; Paparella, Michael M.; Cureoglu, Sebahattin
2016-01-01
Objective Endoscopic procedures are becoming common in middle ear surgery. Inflammation due to chronic ear disease can cause bony erosion of the carotid artery and Fallopian canals, making them more vulnerable during surgery. The objective of this study was to determine whether or not chronic ear disease increases dehiscence of the carotid artery and Fallopian canals. Design Comparative human temporal bone study. Setting Otopathology laboratory. Participants We selected 78 temporal bones from 55 deceased donors with chronic otitis media or cholesteatoma, and then compared those 2 groups with a control group of 27 temporal bones from 19 deceased donors with no middle ear disease. Main outcome measures We analyzed the middle ear, carotid artery canal, and Fallopian canal, looking for signs of dehiscence of its bony coverage, using light microscopy. Results We found an increased incidence in dehiscence of the carotid artery and Fallopian canals in temporal bones with chronic middle ear disease. The size of the carotid artery canal dehiscence was larger in the middle ear diseased groups, and its bony coverage, when present, was also thinner compared to the control group. Dehiscence of the carotid artery canal was more frequently located closer to the promontory. The incidence of Fallopian canal dehiscence was significantly higher in temporal bones from donors older than 18 years with chronic middle ear disease. Conclusion The increased incidence of the carotid artery and Fallopian canal dehiscence in temporal bones with chronic middle ear disease elevates the risk of adverse events during middle ear surgery. Level of Evidence N/A. PMID:27455393
Casey, Rachel K; Damle, Lauren F; Gomez-Lobo, Veronica
2013-06-01
To identify and review cases of isolated fallopian tube torsion (FTT) at our institution to further characterize diagnosis and management. Retrospective review. Tertiary care medical center. Case series of pediatric and adolescent females, <21 years old, with operatively diagnosed isolated fallopian tube torsion from our institution. None. Isolated fallopian tube torsion. Fifteen cases of isolated fallopian tube torsion were identified based on intraoperative diagnosis. Patient ages ranged from 8-15 years old, mean age of 12. Fourteen patients (93%) presented with abdominal pain, 8 (53%) localized to the side of associated torsion. Ultrasonography reports described a tubular structure in 4 patients and an associated ovarian or paraovarian cyst in eleven patients. Suspicion of fallopian tube torsion was only described for those patients with a tubular structure described on ultrasonography report. Intraoperatively, 7 patients (47%) were found to have no associated pathology and 8 (53%) were found to have associated cyst or hydrosalpinx. Eight (53%) patients underwent salipingectomy and 7 (47%) underwent reversal of torsion with drainage of associated cyst or cystectomy. Isolated fallopian tube torsion is a rare condition that seems to occur in younger adolescents. Vague clinical presentation contributes to low preoperative suspicion. Preoperative suspicion may be increased based on radiographic findings of an enlarged tubular structure or an adjacent normal ovary. Management may be considered nonemergent and salpingectomy is controversial. Long-term fertility outcomes must be further assessed for more definitive decisions regarding surgical management. Copyright © 2013 North American Society for Pediatric and Adolescent Gynecology. Published by Elsevier Inc. All rights reserved.
Wolsky, Rebecca J; Price, Matt A; Zaloudek, Charles J; Rabban, Joseph T
2018-05-01
Malignant transformation of the fallopian tube mucosa, followed by exfoliation of malignant cells onto ovarian and/or peritoneal surfaces, has been implicated as the origin of most pelvic high-grade serous carcinoma. Whether a parallel pathway exists for pelvic low-grade serous tumors [ovarian serous borderline tumor (SBT) and low-grade serous carcinoma (LGSC)] remains to be fully elucidated. The literature is challenging to interpret due to variation in the diagnostic criteria and terminology for cytologically low-grade proliferations of the fallopian tube mucosa, as well as variation in fallopian tube specimen sampling. Recently, a candidate fallopian tube precursor to ovarian SBT, so-called papillary tubal hyperplasia, was described in advanced stage patients. The current study was designed to identify fallopian tube mucosal proliferations unique to patients with low-grade serous ovarian tumors (serous cystadenoma, SBT, LGSC) and to determine if they may represent precursors to the ovarian tumors. Fallopian tubes were thinly sliced and entirely examined microscopically, including all of the fimbriated and nonfimbriated portions of the tubes, from patients with ovarian serous cystadenoma (35), SBT (61), and LGSC (11) and from a control population of patients with ovarian mucinous cystadenoma (28), mature cystic teratoma (18) or uterine leiomyoma (14). The slides of the fallopian tubes were examined in randomized order, without knowledge of the clinical history or findings in the ovaries or other organs. Alterations of the mucosa of the fallopian tube were classified as type 1: nonpapillary proliferation of cytologically bland tubal epithelium exhibiting crowding, stratification, and/or tufting without papillary fibrovascular cores or as type 2: papillary alterations consisting of a fibrovascular core lined by a cytologically bland layer of tubal epithelium. A third abnormality, type 3, consisted of detached intraluminal papillae, buds, or nests of epithelium that cytologically resembled the epithelial component of SBT or LGSC. Mucosal proliferations were identified in subsets of all populations, including the control populations. Overall, type 1 proliferations were in 28% to 61% of all patients and type 2 alterations in 4% to 16%. There was no statistically significant difference in the incidence of type 1 or type 2 proliferations between the class of ovarian serous tumors (benign, SBT, LGSC), between early and advanced stage SBT, or between patients with any ovarian serous tumor and the control population of nonserous diagnoses. Type 3 alterations were only identified in patients with advanced stage SBT/LGSC and not in any early stage SBT or cystadenoma. These findings suggest that type 3 alterations floating in the fallopian tube lumen represent exfoliation of tumor cells from ovarian and/or peritoneal origin. Our study did not identify a mucosal-based proliferation of the fallopian tubes that was specific to ovarian low-grade serous tumors. Cytologically bland mucosal proliferations appear to be common in fallopian tubes from patients of all ages and unrelated to ovarian tumorigenesis. A consensus on diagnostic criteria and terminology for these types of proliferations is needed, as well as further study into their etiology, including possible association with hormonal environment.
Endoscope-guided pneumatic dilation for treatment of esophageal achalasia
Chuah, Seng-Kee; Wu, Keng-Liang; Hu, Tsung-Hui; Tai, Wei-Chen; Changchien, Chi-Sin
2010-01-01
Pneumatic dilation (PD) is considered to be the first line nonsurgical therapy for achalasia. The principle of the procedure is to weaken the lower esophageal sphincter by tearing its muscle fibers by generating radial force. The endoscope-guided procedure is done without fluoroscopic control. Clinicians usually use a low-compliance balloon such as Rigiflex dilator to perform endoscope-guided PD for the treatment of esophageal achalasia. It has the advantage of determining mucosal injury during the dilation process, so that a repeat endoscopy is not needed to assess the mucosal tearing. Previous studies have shown that endoscope-guided PD is an efficient and safe nonsurgical therapy with results that compare well with other treatment modalities. Although the results may be promising, long-term follow-up is required in the near future. PMID:20101764
Fallopian Tube Herniation through Left Sided Abdominal Drain Site.
Hussain, Khalid; Masood, Jovaria
2016-06-01
Intra-abdominal drains have been used since long to prevent intra-abdominal collection, and detect any anastomotic leaks. We report a case of left sided fallopian tube herniation from a left lower abdominal drain site in a 27-year female who underwent caesarian section for breach presentation. Several complications related to drain usage has been described but left sided fallopian tube prolapse through drain site has not been reported in literature.
2018-05-18
Estrogen Receptor Negative; HER2/Neu Negative; High Grade Fallopian Tube Serous Adenocarcinoma; High Grade Ovarian Serous Adenocarcinoma; Metastatic Malignant Solid Neoplasm; Primary Peritoneal High Grade Serous Adenocarcinoma; Progesterone Receptor Negative; Recurrent Breast Carcinoma; Recurrent Fallopian Tube Carcinoma; Recurrent Ovarian Carcinoma; Recurrent Primary Peritoneal Carcinoma; Triple-Negative Breast Carcinoma; Unresectable Solid Neoplasm
Scillia, Anthony; Issa, Kimona; McInerney, Vincent K; Milman, Edward; Baltazar, Romulo; Dasti, Umer; Festa, Anthony
2015-08-01
The purpose of this study was to evaluate the accuracy of in vivo acromioclavicular (AC) joint injections without fluoroscopic guidance and assess whether patient demographics affected the accuracy of injections. A consecutive cohort of patients who presented with painful acromioclavicular joints was prospectively evaluated. All patients had clinical and radiographic evidence of AC arthritis, had failed conservative measures, and thus had received intraarticular corticosteroid injections. All injections were performed by experienced fellowship-trained musculoskeletal radiologists and by blinded digital palpation technique. Accuracy of injections was assessed with biplanar fluoroscopic views. Forty-one AC injections in 22 males and 16 females with a mean age of 51 years (range 18 to 78) were identified. Twenty-three injections were in the right shoulder and 18 in the left. Only 15 injections were confirmed to be in the intraarticular AC joint, yielding an accuracy of 36.5%. There were no significant differences in the mean age (54 vs. 52 years; p = 0.58), male-to-female ratio (p = 0.73), and side of the injection between the accurate and inaccurate injections, respectively. Based on the findings of the present study, the authors encourage the use of image guidance for corticosteroid treatment of the AC joint. Level IV Therapeutic Case Series.
Casella, Michela; Dello Russo, Antonio; Pelargonio, Gemma; Bongiorni, Maria Grazia; Del Greco, Maurizio; Piacenti, Marcello; Andreassi, Maria Grazia; Santangeli, Pasquale; Bartoletti, Stefano; Moltrasio, Massimo; Fassini, Gaetano; Marini, Massimiliano; Di Cori, Andrea; Di Biase, Luigi; Fiorentini, Cesare; Zecchi, Paolo; Natale, Andrea; Picano, Eugenio; Tondo, Claudio
2012-10-01
Radiofrequency catheter ablation is the mainstay of therapy for supraventricular tachyarrhythmias. Conventional radiofrequency catheter ablation requires the use of fluoroscopy, thus exposing patients to ionising radiation. The feasibility and safety of non-fluoroscopic radiofrequency catheter ablation has been recently reported in a wide range of supraventricular tachyarrhythmias using the EnSite NavX™ mapping system. The NO-PARTY is a multi-centre, randomised controlled trial designed to test the hypothesis that catheter ablation of supraventricular tachyarrhythmias guided by the EnSite NavX™ mapping system results in a clinically significant reduction in exposure to ionising radiation compared with conventional catheter ablation. The study will randomise 210 patients undergoing catheter ablation of supraventricular tachyarrhythmias to either a conventional ablation technique or one guided by the EnSite NavX™ mapping system. The primary end-point is the reduction of the radiation dose to the patient. Secondary end-points include procedural success, reduction of the radiation dose to the operator, and a cost-effectiveness analysis. In a subgroup of patients, we will also evaluate the radiobiological effectiveness of dose reduction by assessing acute chromosomal DNA damage in peripheral blood lymphocytes. NO-PARTY will determine whether radiofrequency catheter ablation of supraventricular tachyarrhythmias guided by the EnSite NavX™ mapping system is a suitable and cost-effective approach to achieve a clinically significant reduction in ionising radiation exposure for both patient and operator.
Fallopian tube cancer. The Roswell Park experience.
Rose, P G; Piver, M S; Tsukada, Y
1990-12-15
Sixty-four patients with primary fallopian tube cancer treated at Roswell Park Memorial Institute from 1964 to 1987 underwent retrospective clinicopathologic review. In 40 patients fallopian tube cancer was the only primary, but in 24 patients primary fallopian tube cancer was part of a multifocal upper genital tract malignancy. Of the 40 patients with unifocal fallopian disease, the median survival was 28 months. Only 15% of patients were alive and disease free with follow-up ranging from 22 to 141 months (median, 90.5 months). Survival was not associated with stage of disease, tumor histology, grade, or depth of invasion in this series. Fourteen patients who received cisplatin-based chemotherapy were evaluable for response. Three patients (21%) responded; two complete and one partial. Twelve patients without clinical evidence of disease underwent second-look procedures, ten laparotomy and two laparoscopy. Four of ten second-look laparotomies were negative. Secondary debulking was done in three of four patients with gross disease, one of which had a negative third-look laparotomy. Negative laparotomy, second-look or third-look, was associated with improved survival (P = 0.016). One of the two laparoscopies was negative, but the patient recurred. In the remaining 24 patients cancer of the fallopian tube was part of a multifocal upper genital tract malignancy. In 12 patients tubal disease was invasive, and in 12, it was in situ. Separate primaries occurred in the ovaries (n = 20); uterus (n = 7); and cervix (n = 2). This represents 1.3% of ovarian malignancies treated at Roswell Park Memorial Institute during the study period. Fallopian tube cancer seems as virulent as ovarian cancer with few long-term survivors. It is frequently associated with other sites of upper genital tract malignancy. Second-look laparotomy is an important predictor of survival. Second-look laparoscopy may be useful if positive.
Zhu, Jie; Xu, Yuanming; Rashedi, Alexandra S.; Pavone, Mary Ellen; Kim, J. Julie; Woodruff, Teresa K.; Burdette, Joanna E.
2016-01-01
Study question Do interactions between human fallopian tube epithelium and murine follicles occur during an artificial reproductive cycle in a co-culture system in vitro? Summary answer In a co-culture system, human fallopian tissues responded to the menstrual cycle mimetic by changes in morphology and levels of secreted factors, and increasing murine corpus luteum progesterone secretion. What is known already The entire fallopian tube epithelium, including ciliated and secretory cells, can be regulated in the reproductive cycle. Currently, there are no in vitro culture models that can monitor fallopian tissues in real time in response to factors produced by the ovary. In addition, there are no reports on the impact of fallopian tissue on ovarian function during the menstrual cycle. Study design, samples/materials, methods Human fallopian tissue (n = 24) was obtained by routine hysterectomies from women (aged 26–50 years, mean age = 43.6) who had not undergone exogenous hormonal treatment for at least 3 months prior to surgery. CD1 female mice were used for ovarian follicle isolation. The human fallopian epithelium layers were either co-cultured with five murine multilayer secondary follicles (150–180 μm follicles, encapsulated in one alginate gel bead) for 15 days or received stepwise steroid hormone additions for 13 days. The fallopian tissue morphology and cilia beating rate, as measured by an Andor Spinning Disk Confocal, were investigated. Oviduct-specific glycoprotein 1 (OVGP1), human insulin-like growth factor 1 (hIGF1), vascular endothelial growth factor A (VEGF-A) and interleukin 8 (IL8) as biological functional markers were measured either by ELISA or western blot to indicate dynamic changes in the fallopian epithelium during the reproductive cycle generated by mouse follicles or by stepwise steroid hormone induction. Three or four patients in each experiment were recruited for replicates. Data were presented as mean ± SD and further analyzed using one-way ANOVA followed by Tukey's multiple comparisons test. Main results and the role of chance The cultured fallopian tube epithelium responded to exogenous steroid hormone stimulation, as demonstrated by enhanced cilia beating rate (~25% increase, P = 0.04) and an increase in OVGP1 secretion (P = 0.02) in response to 1 nM estradiol (E2) treatment when compared with 0.1 nM E2. Conversely, 10 nM progesterone plus 1 nM E2 suppressed cilia beating rate by ~30% (P = 0.008), while OVGP1 secretion was suppressed by 0.1 nM E2 plus 50 nM progesterone (P = 0.002 versus 1 nM E2 alone). Human fallopian tube epithelium was co-cultured with murine secondary follicles to mimic the human menstrual cycle. OVGP1 and VEGF-A secretion from fallopian tissue was similar with stepwise hormone treatment and when cultured with murine follicles. However, the secretion patterns of hIGF1 and IL8 differed in the luteal phase when comparing steroid treatment with follicle co-culture. In co-culture, hIGF1 secretion was suppressed in the luteal versus follicular phase (P = 0.005) but stepwise hormone treatment had no effect on hIGF1. In co-culture, IL8 secretion was also suppressed on luteal phase day 15 (P = 0.013) versus follicular phase day 7, but IL8 secretion increased continuously under high E2/progesterone treatment (P = 0.003 for D13 versus D3). In the co-culture system, the corpus luteum continuously produced progesterone in the presence of fallopian tube tissue until Day 18 while, without fallopian tissue, progesterone started to drop from Day 13. Limitations, reasons for caution One limitation of this study is that murine follicles were used to mimic the human menstrual cycle. However, although secretion patterns of peptide hormones such as inhibins and activins differ in mice and humans, the co-culture system used here did reveal interactions between the tissues that govern reproductive function. Wider implications of the findings In vitro co-culture models of fallopian reproductive tissues with ovarian follicles can provide an important tool for understanding fertility and for uncovering the mechanisms responsible for reduced fertility. In addition, the role of oviductal secretions and how they influence ovarian function, such as the production of progesterone during the menstrual cycle, can be uncovered using this model. Large-scale data None. Study funding and competing interest(s) This work was funded by grants from the NIH (UH3TR001207), the American Cancer Society (RSG-12-230-01-TBG) and NIH (R01EB014806). The authors declare no competing financial interest. PMID:27542947
Zhu, Jie; Xu, Yuanming; Rashedi, Alexandra S; Pavone, Mary Ellen; Kim, J Julie; Woodruff, Teresa K; Burdette, Joanna E
2016-11-01
Do interactions between human fallopian tube epithelium and murine follicles occur during an artificial reproductive cycle in a co-culture system in vitro? In a co-culture system, human fallopian tissues responded to the menstrual cycle mimetic by changes in morphology and levels of secreted factors, and increasing murine corpus luteum progesterone secretion. The entire fallopian tube epithelium, including ciliated and secretory cells, can be regulated in the reproductive cycle. Currently, there are no in vitro culture models that can monitor fallopian tissues in real time in response to factors produced by the ovary. In addition, there are no reports on the impact of fallopian tissue on ovarian function during the menstrual cycle. Human fallopian tissue (n = 24) was obtained by routine hysterectomies from women (aged 26-50 years, mean age = 43.6) who had not undergone exogenous hormonal treatment for at least 3 months prior to surgery. CD1 female mice were used for ovarian follicle isolation. The human fallopian epithelium layers were either co-cultured with five murine multilayer secondary follicles (150-180 μm follicles, encapsulated in one alginate gel bead) for 15 days or received stepwise steroid hormone additions for 13 days. The fallopian tissue morphology and cilia beating rate, as measured by an Andor Spinning Disk Confocal, were investigated. Oviduct-specific glycoprotein 1 (OVGP1), human insulin-like growth factor 1 (hIGF1), vascular endothelial growth factor A (VEGF-A) and interleukin 8 (IL8) as biological functional markers were measured either by ELISA or western blot to indicate dynamic changes in the fallopian epithelium during the reproductive cycle generated by mouse follicles or by stepwise steroid hormone induction. Three or four patients in each experiment were recruited for replicates. Data were presented as mean ± SD and further analyzed using one-way ANOVA followed by Tukey's multiple comparisons test. The cultured fallopian tube epithelium responded to exogenous steroid hormone stimulation, as demonstrated by enhanced cilia beating rate (~25% increase, P = 0.04) and an increase in OVGP1 secretion (P = 0.02) in response to 1 nM estradiol (E 2 ) treatment when compared with 0.1 nM E 2 . Conversely, 10 nM progesterone plus 1 nM E 2 suppressed cilia beating rate by ~30% (P = 0.008), while OVGP1 secretion was suppressed by 0.1 nM E 2 plus 50 nM progesterone (P = 0.002 versus 1 nM E 2 alone). Human fallopian tube epithelium was co-cultured with murine secondary follicles to mimic the human menstrual cycle. OVGP1 and VEGF-A secretion from fallopian tissue was similar with stepwise hormone treatment and when cultured with murine follicles. However, the secretion patterns of hIGF1 and IL8 differed in the luteal phase when comparing steroid treatment with follicle co-culture. In co-culture, hIGF1 secretion was suppressed in the luteal versus follicular phase (P = 0.005) but stepwise hormone treatment had no effect on hIGF1. In co-culture, IL8 secretion was also suppressed on luteal phase day 15 (P = 0.013) versus follicular phase day 7, but IL8 secretion increased continuously under high E 2 /progesterone treatment (P = 0.003 for D13 versus D3). In the co-culture system, the corpus luteum continuously produced progesterone in the presence of fallopian tube tissue until Day 18 while, without fallopian tissue, progesterone started to drop from Day 13. One limitation of this study is that murine follicles were used to mimic the human menstrual cycle. However, although secretion patterns of peptide hormones such as inhibins and activins differ in mice and humans, the co-culture system used here did reveal interactions between the tissues that govern reproductive function. In vitro co-culture models of fallopian reproductive tissues with ovarian follicles can provide an important tool for understanding fertility and for uncovering the mechanisms responsible for reduced fertility. In addition, the role of oviductal secretions and how they influence ovarian function, such as the production of progesterone during the menstrual cycle, can be uncovered using this model. None. This work was funded by grants from the NIH (UH3TR001207), the American Cancer Society (RSG-12-230-01-TBG) and NIH (R01EB014806). The authors declare no competing financial interest. © The Author 2016. Published by Oxford University Press on behalf of the European Society of Human Reproduction and Embryology. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Galster, M; Guhl, C; Uder, M; Adamus, R
2013-05-01
Efficacy of radiation protection tools for the eye lens dose of the radiologist in fluoroscopic interventions. A patient phantom was exposed using a fluoroscopic system. Dose measurements were made at the eye location of the radiologist using an ionization chamber. The setting followed typical fluoroscopic interventions. The reduction of scattered radiation by the equipment-mounted shielding (undercouch drapes and overcouch top) was evaluated. The ceiling-suspended lead acrylic glass screen was tested in scattered radiation generated by a slab phantom. The protective properties of different lead glass goggles and lead acrylic visors were evaluated by thermoluminescence measurements on a head phantom in the primary beam. The exposition of the lens of about 110 to 550 μSv during radiologic interventions is only slightly reduced by the undercouch drapes. Applying the top in addition to the drapes reduces the lens dose by a factor of 2 for PA projections. In 25°LAO the dose is reduced by a factor between 1.2 and 5. The highest doses were measured for AP angulations furthermore the efficacy of the equipment-mounted shielding is minimal. The ceiling-suspended lead screen reduced scatter by a factor of about 30. The lead glass goggles and visors reduced the lens dose up to a factor of 8 to 10. Depending on the specific design, the tested models are less effective especially for radiation from lateral with cranial angulation of the beam. Occasionally the visors even caused an increase of dose. The exposition of the eye lens can be kept below the new occupational limit recommended by the ICRP if the radiation shielding equipment is used consistently. © Georg Thieme Verlag KG Stuttgart · New York.
A Hybrid Reality Radiation-free Simulator for Teaching Wire Navigation Skills
Kho, Jenniefer Y.; Johns, Brian D.; Thomas, Geb. W.; Karam, Matthew D.; Marsh, J. Lawrence; Anderson, Donald D.
2016-01-01
Objectives Surgical simulation is an increasingly important method to facilitate the acquiring of surgical skills. Simulation can be helpful in developing hip fracture fixation skills because it is a common procedure for which performance can be objectively assessed (i.e., the tip-apex distance). The procedure requires fluoroscopic guidance to drill a wire along an osseous trajectory to a precise position within bone. The objective of this study was to assess the construct validity for a novel radiation-free simulator designed to teach wire navigation skills in hip fracture fixation. Methods Novices (N=30) with limited to no surgical experience in hip fracture fixation and experienced surgeons (N=10) participated. Participants drilled a guide wire in the center-center position of a synthetic femoral head in a hip fracture simulator, using electromagnetic sensors to track the guide wire position. Sensor data were gathered to generate fluoroscopic-like images of the hip and guide wire. Simulator performance of novice and experienced participants was compared to measure construct validity. Results The simulator was able to discriminate the accuracy in guide wire position between novices and experienced surgeons. Experienced surgeons achieved a more accurate tip-apex distance than novices (13 vs 23 mm, respectively, p=0.009). The magnitude of improvement on successive simulator attempts was dependent on level of expertise; tip-apex distance improved significantly in the novice group, while it was unchanged in the experienced group. Conclusions This hybrid reality, radiation-free hip fracture simulator, which combines real-world objects with computer-generated imagery demonstrates construct validity by distinguishing the performance of novices and experienced surgeons. There is a differential effect depending on level of experience, and it could be used as an effective training tool in novice surgeons. PMID:26165262
Isolated torsion of fallopian tube during pregnancy; report of two cases.
Yalcin, O T; Hassa, H; Zeytinoglu, S; Isiksoy, S
1997-08-01
Isolated torsion of fallopian tube is very uncommon during pregnancy. Predisposing factors for torsion are hydrosalpinx, prior tubal operation, pelvic congestion, ovarian and paraovarian masses and trauma. Although the most important clinical symptom is abdominal pain in lower quadrants, the diagnosis is usually established during the operation performed for acute abdomen and salpingectomy is almost always necessary. Two cases of torsion of fallopian tube during pregnancy, one with hydrosalpinx, the other with paratubal cyst are presented and symptoms and predisposing factors are discussed.
Praveen, Alampath; Sreekumar, Karumathil Pullara; Nazar, Puthukudiyil Kader; Moorthy, Srikanth
2012-04-01
Thoracic duct embolization (TDE) is an established radiological interventional procedure for thoracic duct injuries. Traditionally, it is done under fluoroscopic guidance after opacifying the thoracic duct with bipedal lymphangiography. We describe our experience in usinga heavily T2W sequence for guiding thoracic duct puncture and direct injection of glue through the puncture needle without cannulating the duct.
Santos, William S; Belinato, Walmir; Perini, Ana P; Caldas, Linda V E; Galeano, Diego C; Santos, Carla J; Neves, Lucio P
2018-01-01
In this study we evaluated the occupational exposures during an abdominal fluoroscopically guided interventional radiology procedure. We investigated the relation between the Body Mass Index (BMI), of the patient, and the conversion coefficient values (CC) for a set of dosimetric quantities, used to assess the exposure risks of medical radiation workers. The study was performed using a set of male and female virtual anthropomorphic phantoms, of different body weights and sizes. In addition to these phantoms, a female and a male phantom, named FASH3 and MASH3 (reference virtual anthropomorphic phantoms), were also used to represent the medical radiation workers. The CC values, obtained as a function of the dose area product, were calculated for 87 exposure scenarios. In each exposure scenario, three phantoms, implemented in the MCNPX 2.7.0 code, were simultaneously used. These phantoms were utilized to represent a patient and medical radiation workers. The results showed that increasing the BMI of the patient, adjusted for each patient protocol, the CC values for medical radiation workers decrease. It is important to note that these results were obtained with fixed exposure parameters. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
Stages of Ovarian Epithelial, Fallopian Tube, and Primary Peritoneal Cancer
... of Ovarian Germ Cell Tumors Ovarian Low Malignant Potential Tumors Symptoms, Tests, Prognosis, & Stages Treatment of Ovarian Low Malignant Potential Tumors Prevention of Ovarian, Fallopian Tube, & Primary Peritoneal ...
Entrapment of Guide Wire in an Inferior Vena Cava Filter: A Technique for Removal
DOE Office of Scientific and Technical Information (OSTI.GOV)
Abdel-Aal, Ahmed Kamel, E-mail: akamel@uabmc.edu; Saddekni, Souheil; Hamed, Maysoon Farouk
Entrapment of a central venous catheter (CVC) guide wire in an inferior vena cava (IVC) filter is a rare, but reported complication during CVC placement. With the increasing use of vena cava filters (VCFs), this number will most likely continue to grow. The consequences of this complication can be serious, as continued traction upon the guide wire may result in filter dislodgement and migration, filter fracture, or injury to the IVC. We describe a case in which a J-tipped guide wire introduced through a left subclavian access without fluoroscopic guidance during CVC placement was entrapped at the apex of anmore » IVC filter. We describe a technique that we used successfully in removing the entrapped wire through the left subclavian access site. We also present simple useful recommendations to prevent this complication.« less
Treatment Option Overview (Ovarian Epithelial, Fallopian Tube, and Primary Peritoneal Cancer)
... of Ovarian Germ Cell Tumors Ovarian Low Malignant Potential Tumors Symptoms, Tests, Prognosis, & Stages Treatment of Ovarian Low Malignant Potential Tumors Prevention of Ovarian, Fallopian Tube, & Primary Peritoneal ...
2017-05-04
Endometrial Clear Cell Adenocarcinoma; Estrogen Receptor Negative; Ovarian Clear Cell Cystadenocarcinoma; Recurrent Fallopian Tube Carcinoma; Recurrent Ovarian Carcinoma; Recurrent Primary Peritoneal Carcinoma; Recurrent Uterine Corpus Carcinoma
Treatment Options by Stage (Ovarian Epithelial, Fallopian Tube, and Primary Peritoneal Cancer)
... of Ovarian Germ Cell Tumors Ovarian Low Malignant Potential Tumors Symptoms, Tests, Prognosis, & Stages Treatment of Ovarian Low Malignant Potential Tumors Prevention of Ovarian, Fallopian Tube, & Primary Peritoneal ...
Prat, Jaime
2015-10-01
Ovarian, fallopian tube, and peritoneal cancers have a similar clinical presentation and are treated similarly, and current evidence supports staging all 3 cancers in a single system. The primary site (i.e. ovary, fallopian tube, or peritoneum) should be designated where possible. The histologic type should be recorded. Intraoperative rupture ("surgical spill") is IC1; capsule ruptured before surgery or tumor on ovarian or fallopian tube surface is IC2; and positive peritoneal cytology with or without rupture is IC3. The new staging includes a revision of stage III patients; assignment to stage IIIA1 is based on spread to the retroperitoneal lymph nodes without intraperitoneal dissemination. Extension of tumor from omentum to spleen or liver (stage IIIC) should be differentiated from isolated parenchymal metastases (stage IVB). © 2015 American Cancer Society.
Confocal microlaparoscope for imaging the fallopian tube
NASA Astrophysics Data System (ADS)
Wu, Tzu-Yu; Schafer, Rachel; Rouse, Andrew R.; Gmitro, Arthur F.
2012-02-01
Recent evidence suggests that epithelial ovarian cancer may originate in the fimbriated end of the fallopian tube1. Unlike many other cancers, poor access to the ovary and fallopian tubes has limited the ability to study the progression of this deadly disease and to diagnosis it during the early stage when it is most amenable to therapy. We have previously reported on a rigid confocal microlaparoscope system that is currently undergoing a clinical trial to image the epithelial surface of the ovary2. In order to gain in vivo access to the fallopian tubes we have developed a new confocal microlaparoscope with an articulating distal tip. The new instrument builds upon the technology developed for the existing confocal microlaparoscope. It has an ergonomic handle fabricated by a rapid prototyping printer. While maintaining compatibility with a 5 mm trocar, the articulating distal tip of the instrument consists of a 2.2 mm diameter bare fiber bundle catheter with automated dye delivery for fluorescence imaging. This small and flexible catheter design should enable the confocal microlaparoscope to image early stage ovarian cancer arising inside the fallopian tube. Early ex vivo mages of human fallopian tube and in vivo imaging results from recent open surgeries using the rigid confocal microlaparoscope system are presented. Ex vivo images from animal models using the new articulating bare fiber system are also presented. These high quality images collected by the new flexible system are similar in quality to those obtained from the epithelial surface of ovaries with the rigid clinical confocal microlaparoscope.
Acute presentation of a benign cystadenofibroma of the fallopian tube: a case report
2010-01-01
Introduction Cystadenofibromas are rare benign tumors of the fallopian tube with only 15 reported cases worldwide. They are usually asymptomatic and are found incidentally. This case is presented on account of its rarity and to the best of our knowledge, is the first reported case of cystadenofibroma of the fallopian tube discovered during an appendicectomy. Case presentation We report a rare case of cystadenofibroma of the fallopian tube in a 19-year-old Caucasian woman who presented with sudden onset of right iliac fossa pain. A clinical diagnosis of appendicitis was made and she was taken to the operating theater for an appendicectomy. Intraoperatively, the appendix appeared normal. However, the 8 cm cyst contained within the right ovary and the blood in the pelvis warranted a salpingo-oopherectomy. Our patient made an uneventful recovery and was discharged after four days. Histology revealed a benign cystadenofibroma of the fallopian tube. There was no evidence of recurrence in the follow-up period of 12 months. Conclusion Cystadenofibromas are benign tumors that may macroscopically and ultrasonographically appear malignant. We recommend that the diagnosis of cystadenofibroma is considered prior to performing radical surgery that may affect the fecundity of these patients. Cystadenofibromas confined to the fallopian tube can be treated curatively with unilateral salpingo-oophorectomy, without the need for any further treatment. However, long-term follow-up of more cases is required to draw more definitive conclusions. PMID:20565766
Ansari, Md Abu Masud; Kumar, Naveen; Kumar, Shailesh; Kumari, Sarita
2016-10-01
Central venous Catheterization (CVC) is a commonly performed procedure for venous access. It is associated with several complications. We report a rare case of extra luminal entrapment of guide wire during CVC placement in right jugular vein. We report a case of 28 years old female patient presented in our emergency with history of entrapped guide wire in right side of neck during CVC. X-ray showed coiling of guide wire in neck. CT Angiography showed guide wire coursing in between common carotid artery and internal jugular vein (IJV), closely abutting the wall of both vessels. The guide wire was coiled with end coursing behind the esophageal wall. Guide wire was removed under fluoroscopic guide manipulation under local anesthesia. We want to emphasize that even though CVC placement is common and simple procedure, serious complication can occur in hands of untrained operator. The procedure should be performed under supervision, if done by trainee. Force should never be applied to advance the guide wire if resistance is encountered.
Primary Fallopian Tube Carcinoma: A Case Report and Literature Review.
Rexhepi, Meral; Trajkovska, Elizabeta; Ismaili, Hysni; Besimi, Florin; Rufati, Nagip
2017-06-15
Primary fallopian tube carcinoma (PFTC) is a rare tumour of the female genital tract with an incidence of 0.1-1.8% of all genital malignancies, and it is very difficult to diagnose preoperatively, because of its non-specific symptomatology. In most cases, it is an intraoperative finding or a histopathological diagnosis. It is a tumour that histologically and clinically resembles epithelial ovarian cancer. We are reporting a case of a 62-year-old, postmenopausal women with primary fallopian tube carcinoma of the right fallopian tube in stage IA. The patient has lower abdominal pain, watery vaginal discharge and repeated episodes of bleeding from the vagina. The clinical and radiological findings suggested a right adnexal tumour with elevated CA-125 levels. Total abdominal hysterectomy, bilateral salpingo-oophorectomy, omentectomy and peritoneal washing were performed. Pathologic confirmation of primary serous cystadenocarcinoma of the right fallopian tube was made. Peritoneal washings were negative for malignancy. FIGO stage was considered as IA, and the patient received no courses of chemotherapy and postoperative radiation because she refused it. Ten months after initial surgery, the patient is alive and in good condition. Cytoreduction surgery followed by adequate cycles of chemotherapy is an important strategy to improve patients' prognosis.
Hysterosalpingogram: an essential examination following Essure hysteroscopic sterilisation
Shah, V; Panay, N; Williamson, R; Hemingway, A
2011-01-01
Objectives The aim of this study was to describe our experience of imaging following hysteroscopic sterilisation with the Essure (Conceptus Inc., Mountain View, San Carlos, CA) microinsert, and to underline the importance of a carefully performed follow-up hysterosalpingogram (HSG) in the management of these patients. Methods 18 women underwent the procedure and all returned for follow-up HSG. A standard HSG technique was used and views were acquired to establish microinsert position and tubal occlusion. Results In 16 of the 18 women, adequate microinsert positioning and bilateral tubal occlusion was present. In one woman, a unilateral microinsert occluded the fallopian tube, whereas the other fallopian tube was ligated with a clip. The final patient underwent two studies; both showed well-positioned microinserts but unilateral free spill from the right fallopian tube. There are no reported pregnancies thus far. Conclusion Essure sterilisation coils have a unique appearance when radiographed and are an effective means of permanently occluding the fallopian tubes. HSG is a rapid and safe method of confirming satisfactory placement and tubal occlusion. Non-HSG imaging techniques are suboptimal at detecting patent fallopian tubes and expose patients to the risk of an unwanted and potentially complicated pregnancy. PMID:21123309
Sister Mary Joseph's nodule as the first presenting sign of primary fallopian tube adenocarcinoma.
Kirshtein, Boris; Meirovitz, Mihai; Okon, Elimelech; Piura, Benjamin
2006-01-01
Umbilical metastasis (Sister Mary Joseph's nodule) is often the first sign of intraabdominal and/or pelvic carcinoma. We describe the fourth case reported in the literature of Sister Mary Joseph's nodule originating from fallopian tube carcinoma. In a 54-year-old woman, Sister Mary Joseph's nodule was unexpectedly detected during umbilical hernia repair. Subsequent laparoscopy revealed a 2-cm friable tumor located at the fimbriated end of right fallopian tube and 1-cm peritoneal implant in the pouch of Douglas. Laparoscopic bilateral adnexectomy and resection of the peritoneal implant were performed. Because frozen section examination revealed fallopian tube carcinoma, the procedure was continued with laparotomy including total abdominal hysterectomy, omentectomy, and pelvic lymph node sampling. Final diagnosis was stage IIIB fallopian tube carcinoma. The patient received postoperative adjuvant chemotherapy with single-agent carboplatin and has remained alive and with no evidence of disease. It is concluded that in cases of Sister Mary Joseph's nodule, laparoscopy can be a useful tool in the search of the primary tumor in the abdomen and/or pelvis. Laparoscopy can provide crucial information with respect to the location, size, and feasibility of optimal surgical resection of the intraabdominal and/or pelvic tumors.
2017-07-10
Adult Hepatocellular Carcinoma; Advanced Adult Hepatocellular Carcinoma; Endometrial Serous Adenocarcinoma; Localized Non-Resectable Adult Liver Carcinoma; Lung Carcinoid Tumor; Malignant Pancreatic Gastrinoma; Malignant Pancreatic Glucagonoma; Malignant Pancreatic Insulinoma; Malignant Pancreatic Somatostatinoma; Metastatic Digestive System Neuroendocrine Tumor G1; Ovarian Carcinosarcoma; Ovarian Endometrioid Adenocarcinoma; Ovarian Seromucinous Carcinoma; Ovarian Serous Surface Papillary Adenocarcinoma; Pancreatic Alpha Cell Adenoma; Pancreatic Beta Cell Adenoma; Pancreatic Delta Cell Adenoma; Pancreatic G-Cell Adenoma; Pancreatic Polypeptide Tumor; Recurrent Adult Liver Carcinoma; Recurrent Digestive System Neuroendocrine Tumor G1; Recurrent Fallopian Tube Carcinoma; Recurrent Ovarian Carcinoma; Recurrent Pancreatic Neuroendocrine Carcinoma; Recurrent Primary Peritoneal Carcinoma; Recurrent Uterine Corpus Carcinoma; Regional Digestive System Neuroendocrine Tumor G1; Stage IIIA Fallopian Tube Cancer; Stage IIIA Ovarian Cancer; Stage IIIA Primary Peritoneal Cancer; Stage IIIA Uterine Corpus Cancer; Stage IIIB Fallopian Tube Cancer; Stage IIIB Ovarian Cancer; Stage IIIB Primary Peritoneal Cancer; Stage IIIB Uterine Corpus Cancer; Stage IIIC Fallopian Tube Cancer; Stage IIIC Ovarian Cancer; Stage IIIC Primary Peritoneal Cancer; Stage IIIC Uterine Corpus Cancer; Stage IV Fallopian Tube Cancer; Stage IV Ovarian Cancer; Stage IV Primary Peritoneal Cancer; Stage IVA Uterine Corpus Cancer; Stage IVB Uterine Corpus Cancer; Uterine Carcinosarcoma
2017-01-24
Ovarian Papillary Serous Carcinoma; Ovarian Serous Cystadenocarcinoma; Recurrent Fallopian Tube Cancer; Recurrent Ovarian Epithelial Cancer; Recurrent Ovarian Germ Cell Tumor; Recurrent Primary Peritoneal Cavity Cancer
CT-guided robotically-assisted infiltration of foot and ankle joints.
Wiewiorski, Martin; Valderrabano, Victor; Kretzschmar, Martin; Rasch, Helmut; Markus, Tanja; Dziergwa, Severine; Kos, Sebastian; Bilecen, Deniz; Jacob, Augustinus Ludwig
2009-01-01
It was our aim to describe a CT-guided robotically-assisted infiltration technique for diagnostic injections in foot and ankle orthopaedics. CT-guided mechatronically-assisted joint infiltration was performed on 16 patients referred to the orthopaedic department for diagnostic foot and ankle assessment. All interventions were performed using an INNOMOTION-assistance device on a multislice CT scanner in an image-guided therapy suite. Successful infiltration was defined as CT localization of contrast media in the target joint. Additionally, pre- and post-interventional VAS pain scores were assessed. All injections (16/16 joints) were technically successful. Contrast media deposit was documented in all targeted joints. Significant relief of pain was noted by all 16 patients (p<0.01). CT-guided robotically-assisted intervention is an exact, reliable and safe application method for diagnostic infiltration of midfoot and hindfoot joints. The high accuracy and feasibility in a clinical environment make it a viable alternative to the commonly used fluoroscopic-guided procedures.
Praveen, Alampath; Sreekumar, Karumathil Pullara; Nazar, Puthukudiyil Kader; Moorthy, Srikanth
2012-01-01
Thoracic duct embolization (TDE) is an established radiological interventional procedure for thoracic duct injuries. Traditionally, it is done under fluoroscopic guidance after opacifying the thoracic duct with bipedal lymphangiography. We describe our experience in usinga heavily T2W sequence for guiding thoracic duct puncture and direct injection of glue through the puncture needle without cannulating the duct. PMID:23162248
General Information About Ovarian, Fallopian Tube, and Primary Peritoneal Cancer
... condition or to keep cancer from starting. General Information About Ovarian, Fallopian Tube, and Primary Peritoneal Cancer ... PDQ Screening and Prevention Editorial Board . Clinical Trial Information A clinical trial is a study to answer ...
Impact of Duplex arterial mapping on decision making in non-acute ischemic limb patients.
Elbadawy, A; Aly, H; Ibrahim, M; Bakr, H
2015-12-01
The aim of this study was to demonstrate the impact of Duplex arterial mapping on decision making in non-acute ischemic limb patient group reporting pain onset between 15 days and 3 months. We prospectively evaluated patients presented with critical limb ischemia who reported pain onset of duration between 15 days and 3 months in one-year period. Our series included thirty cases (mean age=61.3 years old), as Duplex arterial mapping was the sole preoperative imaging tool performed in all of them. All patients, in whom duplex indicated thrombosis in long occluded segments, were candidates for fluoroscopically guided thrombectomy. When Duplex defined chronic arterial occlusions, patients underwent endovascular or bypass revascularisation procedures. Impact of Duplex wall interrogation on decision-making between the two groups (subacute and chronic) was measured. Duplex arterial mapping categorized correctly all 30 patients into either subacute ischemia with removable clot (N.=14) or chronic ischemia (N.=16). Fluoroscopic guided thrombectomy was performed in 14 cases when Duplex advised long occluded arterial segments as indicted by intact intima with echogenic thrombus inside. Bypass surgery was performed in 8 patients. Percutaneous transluminal angioplasty (PTA) was done in 7 cases and thrombendartrectomy of common femoral artery in a single case. One-year patency rate in our series was 86.6%. It was 71.4% in thrombosis group. Limb salvage rate was 93.3%. Duplex arterial mapping could be used to differentiate the subacute ischemia with removable thrombus and chronic arterial occlusions guiding for the best revascularization procedure accordingly.
Chu, James C.H.; Hsi, Wen Chien; Hubbard, Lincoln; Zhang, Yunkai; Bernard, Damian; Reeder, Pamela; Lopes, Demetrius
2005-01-01
A hospital‐based magnetic guidance system (MGS) was installed to assist a physician in navigating catheters and guide wires during interventional cardiac and neurosurgical procedures. The objective of this study is to examine the performance of this magnetic field‐guided navigation system. Our results show that the system's radiological imaging components produce images with quality similar to that produced by other modern fluoroscopic devices. The system's magnetic navigation components also deflect the wire and catheter tips toward the intended direction. The physician, however, will have to oversteer the wire or catheter when defining the steering angle during the procedure. The MGS could be clinically useful in device navigation deflection and vessel access. PACS numbers: 07.55.Db, 07.85.‐m PMID:16143799
Chronic stress effects and their reversibility on the Fallopian tubes and uterus in rats.
Divyashree, S; Yajurvedi, H N
2018-01-01
The durational effects of chronic stress on the Fallopian tubes and uterus were studied by exposing rats to stressors in the form of restraint (1h) and forced swimming (15min) daily for 4, 8 or 12 weeks. One group of stressed rats from each time period was then maintained without exposure to stressors for a further 4 weeks to assess their ability to recover from stress. All time periods of stress exposure resulted in decreased weight of the body and Fallopian tubes; however, the relative weight of the uterus and serum concentrations of oestradiol and insulin increased significantly. The antioxidant potential was decreased with increased malondialdehyde concentrations in the Fallopian tubes following all durations of exposure and after 4 and 8 weeks of stress exposure in the uterus. Interestingly, rats stressed for 12 weeks showed an increase in serum testosterone concentration and antioxidant enzyme activities with a decrease in malondialdehyde concentration in the uterus. The antioxidant enzyme activities and malondialdehyde concentration in the Fallopian tubes of all recovery group rats were similar to stressed rats. However, in the uterus these parameters were similar to controls in recovery group rats after 4 weeks or 8 weeks of exposure, but after 12 weeks of stress exposure these parameters did not return to control levels following the recovery period. These results reveal, for the first time, that chronic stress elicits an irreversible decrease in antioxidant defence in the Fallopian tubes irrespective of exposure duration, whereas the uterus develops reversible oxidative stress under short-term exposure but increased antioxidant potential with endometrial proliferation following long-term exposure.
Ovarian, Fallopian Tube, & Primary Peritoneal Cancer Prevention (PDQ®)—Patient Version
Ovarian, fallopian tube, and primary peritoneal cancer prevention includes reducing known risk factors and increasing protective factors. Some risk factors can be avoided, others cannot. Learn more about preventing these cancers in this expert-reviewed summary.
Ovarian Epithelial, Fallopian, & Peritoneal Cancer Treatment (PDQ®)—Health Professional Version
Ovarian epithelial, fallopian tube, and primary peritoneal cancer treatments include surgery, chemotherapy, targeted therapy, and PARP inhibitors. Get detailed information about these cancers, (newly diagnosed or recurrent) and how they are treated in this summary for clinicians.
2017-07-24
Ovarian Clear Cell Cystadenocarcinoma; Ovarian Endometrioid Adenocarcinoma; Ovarian Seromucinous Carcinoma; Ovarian Serous Cystadenocarcinoma; Recurrent Fallopian Tube Carcinoma; Recurrent Ovarian Carcinoma; Recurrent Primary Peritoneal Carcinoma; Undifferentiated Ovarian Carcinoma
Primary Fallopian Tube Carcinoma: A Case Report and Literature Review
Rexhepi, Meral; Trajkovska, Elizabeta; Ismaili, Hysni; Besimi, Florin; Rufati, Nagip
2017-01-01
BACKGROUND: Primary fallopian tube carcinoma (PFTC) is a rare tumour of the female genital tract with an incidence of 0.1-1.8% of all genital malignancies, and it is very difficult to diagnose preoperatively, because of its non-specific symptomatology. In most cases, it is an intraoperative finding or a histopathological diagnosis. It is a tumour that histologically and clinically resembles epithelial ovarian cancer. CASE PRESENTATION: We are reporting a case of a 62-year-old, postmenopausal women with primary fallopian tube carcinoma of the right fallopian tube in stage IA. The patient has lower abdominal pain, watery vaginal discharge and repeated episodes of bleeding from the vagina. The clinical and radiological findings suggested a right adnexal tumour with elevated CA-125 levels. Total abdominal hysterectomy, bilateral salpingo-oophorectomy, omentectomy and peritoneal washing were performed. Pathologic confirmation of primary serous cystadenocarcinoma of the right fallopian tube was made. Peritoneal washings were negative for malignancy. FIGO stage was considered as IA, and the patient received no courses of chemotherapy and postoperative radiation because she refused it. Ten months after initial surgery, the patient is alive and in good condition. CONCLUSION: Cytoreduction surgery followed by adequate cycles of chemotherapy is an important strategy to improve patients’ prognosis. PMID:28698755
Andrade, G H B; Simão, V A; Souza, B R; Chuffa, L G A; Camargo, I C C
2018-02-01
Anabolic androgenic steroids (AAS) are recommended for therapeutic clinic, but their use has increased in recent decades for aesthetic reasons. No study has evaluated the impact of AAS in the fallopian tube, after treatment and recovery periods. Herein, the aim of study was to investigate the effects of Nandrolone Decanoate (ND), administered in different doses (1.87; 3.75; 7.5 and 15 mg/kg) on the ampulla of the fallopian tube in rats, following post-treatment (PT; 15 consecutive days) and post-recovery (PR; 30 consecutive days) periods. The control group received mineral oil. Estrous cycle was monitored daily during both periods and in sequence the rats (n = 8/group/period) were killed. All ND-treated animals showed estral acyclicity during the PT and PR periods, but the histomorphometric changes in the fallopian tube varied according to the ND dose level. The expression of AR, ERα and ERβ varied in the nucleus and cytoplasm of epithelial cells. No AR expression was observed in the stroma. The muscle cells exhibited variation in immunostaining. In conclusion, ND promoted histomorphometric and immunohistochemical changes in the ampullary portion of the fallopian tube after treatment and recovery periods in a dose-independent manner. Copyright © 2018 Elsevier Ltd. All rights reserved.
Torsion of the fallopian tube--a late complication of sterilisation.
Sivanesaratnam, V
1986-02-01
Torsion of an intact fallopian tube, unaccompanied by torsion of the ipsilateral ovary, was noted as a complication of bilateral tubal occlusion by the Pomeroy method in a 45-year old Indian woman. The sterilization was performed 5 years previously, at the time of Cesarean section delivery. The patient presented with a history of pain in the right iliac fossa. Laparotomy showed that the distal segment of the right fallopian tube was twisted 3 times on the distal mesosalpinx and appeared tense and gangrenous. The right ovary was normal and a 2 cm gap was noted between the proximal and distal segments of the tube. As a rare complication of the Pomeroy method, the gap in the tube can allow the distal mesosalpinx to act as a pedicle, and with a long mesosalpinx, the fimbriated segment of the tube lies free and may swing and twist to produce torsion. The occurrence of torsion is further promoted by a vascular disturbance leading to venous congestion, edema, and increased weight of the free fimbrial end of the tube. In those patients with a history of sterilization, torsion of the fallopian tube should be considered in the differential diagnosis of acute lower abdominal pain. Torsion of the fallopian tube has also been reported following other methods of tubal occlusion, including cautery and clips.
Auer, Katharina; Bachmayr-Heyda, Anna; Aust, Stefanie; Grunt, Thomas W; Pils, Dietmar
2017-03-01
High grade serous ovarian cancer (HGSOC) is characterized by extensive local, i.e. peritoneal, tumor spread, manifested in two different clinical presentations, miliary (many millet sized peritoneal implants) and non-miliary (few large exophytically growing peritoneal nodes), and an overall unfavorable outcome. HGSOC is thought to arise from fallopian tube secretory epithelial cells, via so called serous tubal intraepithelial carcinomas (STICs) but an ovarian origin was never ruled out for at least some cases. Comparative transcriptome analyses of isolated tumor cells from fresh HGSOC tissues and (immortalized) ovarian surface epithelial and fallopian tube secretory epithelial cell lines revealed a close relation between putative origin and tumor spread characteristic, i.e. miliary from tubes and non-miliary from ovaries. The latter were characterized by more mesenchymal cell characteristics, more adaptive tumor immune infiltration, and a favorable overall survival. Several molecular sub-classification systems (Crijns' overall survival signature, Yoshihara's subclasses, and a collagen-remodeling signature) seem to already indicate origin. Putative origin alone is a significant independent predictor for HGSOC outcome, validated in independent patient cohorts. Characteristics of both spread types could guide development of new targeted therapeutics, which are urgently needed. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Computerized lateral endoscopic approach to invertebral bodies
NASA Astrophysics Data System (ADS)
Abbasi, Hamid R.; Hariri, Sanaz; Kim, Daniel; Shahidi, Ramin; Steinberg, Gary
2001-05-01
Spinal surgery is often necessary to ease back pain symptoms. Neuronavigation (NN) allows the surgeon to localize the position of his instruments in 3D using pre- operative CT scans registered to intra-operative marker positions in cranial surgeries. However, this tool is unavailable in spinal surgeries for a variety of reasons. For example, because of the spine's many degrees of freedom and flexibility, the geometric relationship of the skin to the internal spinal anatomy is not fixed. Guided by the currently available imperfect 2D images, it is difficult for the surgeon to correct a patient's spinal anomaly; thus surgical relief of back pain is often only temporary. The Image Guidance Laborator's (IGL) goal is to combine the direct optical control of traditional endoscopy with the 3D orientation of NN. This powerful tool requires registration of the patient's anatomy to the surgical navigation system using internal landmarks rather than skin markers. Pre- operative CT scans matched with intraoperative fluoroscopic images can overcome the problem of spinal movement in NN registration. The combination of endoscopy with fluoroscopic registration of vertebral bodies in a NN system provides a 3D intra-operative navigational system for spinal neurosurgery to visualize the internal surgical environment from any orientation in real time. The accuracy of this system integration is being evaluated by assessing the success of nucleotomies and marker implantations guided by NN-registered endoscopy.
The financial impact of flipping the coin.
Gonzalez, Katherine W; Reddy, Shiva R; Mundakkal, Angela A; St Peter, Shawn D
2017-01-01
Esophageal foreign body retrieval is typically performed by rigid or flexible esophagoscopy. Despite evidence supporting the efficacy and safety of balloon extraction, it is rarely performed. We sought to establish the financial benefits of this minimally invasive approach. A retrospective review of 241 children with esophageal coins between 2011 and 2013 was performed. Coins were removed via endoscopy or fluoroscopic-guided balloon retrieval. Timing, symptoms, facility cost, and patient charges were compared. Two hundred patients had attempted balloon retrieval with 80% success. Forty-one patients went directly for operative removal. Patients with respiratory difficulty (p=0.05), wheezing (p<0.01), or fever (p=0.03) were more often taken directly for endoscopic retrieval. The median cost and charges for attempted balloon extraction were $484 and $1647. The median cost and charges for primary endoscopy were $1834 and $6746. The median total cost and charges of attempted balloon extraction including ED, OR, transport, admission, and balloon retrieval were $1231 and $3539 versus $3615 and $12,204 in the primary endoscopy group (p<0.001, p<0.001). Seventeen percent of patients who underwent attempted balloon retrieval were admitted prior to removal compared to 76% who underwent primary endoscopy (p<0.001). Fluoroscopic guided balloon extraction of esophageal coins is a financially prudent choice which shortens hospital stay. III. Retrospective treatment and economic study. Copyright © 2017 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kew, Jacqueline; Davies, Roger P.
2004-01-15
A new method is described for guiding hepato-portalvenous puncture using a longitudinal side-view intravascular ultrasound(L-IVUS) transducer to assist in the performance of transjugularintrahepatic portosystemic shunt (TIPS) in three Australian swine.Simultaneous L-IVUS with an AcuNav (registered) 5-10 MHz 10 Fr transducer(Acuson Corporation, Mountain View, CA, USA) and fluoroscopy guidance was used to image and monitor the hepatic to portal venous puncture,dilatation of the tract, and deployment of the TIPS stent. Flow through the shunt could be demonstrated with both L-IVUS and angiography. TIPS was successful in all swine. The time for portal vein puncture once the target portal vein was identifiedmore » was reduced at each attempt. The number of portal vein puncture attempts was 2, 1, and 1. No post-procedural complication was evident. L-IVUS-guided TIPS is practical and has the potential to improve safety by permitting simultaneous ultrasound and fluoroscopic imaging of the needle and target vascular structures. This technique allows for a more streamlined approach to TIPS, decreasing the fluoroscopic time (hence,decreasing the radiation exposure to the staff and patient) and anesthetic time. In addition, there are improved safety benefits obviating the need for wedged portography, facilitating avoidance of bile duct and hepatic arterial puncture, and minimizing hepatic injury by decreasing liver capsular puncture and the attendant risks.« less
Ovarian, Fallopian Tube, & Primary Peritoneal Cancer Prevention (PDQ®)—Health Professional Version
Ovarian, fallopian tube, and primary peritoneal cancer prevention involves understanding risk and protective factors, and the evidence behind them. Get detailed information about specific risk and protective factors and prevention strategies for these cancer types in this clinician summary.
Ovarian, Fallopian Tube, and Primary Peritoneal Cancer Screening
... decrease the risk of dying from cancer. Scientists study screening tests to find those with the fewest risks and ... of cancer, including ovarian cancer, or other conditions. Studies have also shown that ... Screening tests have risks. The risks of ovarian, fallopian tube, ...
21 CFR 892.1650 - Image-intensified fluoroscopic x-ray system.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Image-intensified fluoroscopic x-ray system. 892... fluoroscopic x-ray system. (a) Identification. An image-intensified fluoroscopic x-ray system is a device intended to visualize anatomical structures by converting a pattern of x-radiation into a visible image...
21 CFR 892.1650 - Image-intensified fluoroscopic x-ray system.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Image-intensified fluoroscopic x-ray system. 892... fluoroscopic x-ray system. (a) Identification. An image-intensified fluoroscopic x-ray system is a device intended to visualize anatomical structures by converting a pattern of x-radiation into a visible image...
2015-02-27
Fallopian Tube Carcinoma; Malignant Ovarian Mixed Epithelial Tumor; Ovarian Brenner Tumor; Ovarian Clear Cell Cystadenocarcinoma; Ovarian Endometrioid Adenocarcinoma; Ovarian Mucinous Cystadenocarcinoma; Ovarian Serous Cystadenocarcinoma; Primary Peritoneal Carcinoma; Recurrent Ovarian Carcinoma; Undifferentiated Ovarian Carcinoma
2018-03-05
Ovarian Endometrioid Adenocarcinoma; Ovarian Seromucinous Carcinoma; Ovarian Serous Cystadenocarcinoma; Ovarian Serous Surface Papillary Adenocarcinoma; Recurrent Fallopian Tube Carcinoma; Recurrent Ovarian Carcinoma; Recurrent Ovarian Germ Cell Tumor; Recurrent Primary Peritoneal Carcinoma; Undifferentiated Ovarian Carcinoma
Ovarian, Fallopian Tube, and Primary Peritoneal Cancer Screening (PDQ®)—Health Professional Version
Ovarian, fallopian tube, and primary peritoneal cancer screening is not currently recommended as part of routine cancer screening. Get detailed information about the potential benefits and harms of screening tests used in these cancers in this summary for clinicians.
2015-05-07
Fallopian Tube Carcinoma; Malignant Ovarian Mixed Epithelial Tumor; Ovarian Brenner Tumor; Ovarian Clear Cell Cystadenocarcinoma; Ovarian Endometrioid Adenocarcinoma; Ovarian Mucinous Cystadenocarcinoma; Ovarian Serous Cystadenocarcinoma; Primary Peritoneal Carcinoma; Stage III Ovarian Cancer; Stage IV Ovarian Cancer; Undifferentiated Ovarian Carcinoma
Risks of Ovarian, Fallopian Tube, and Primary Peritoneal Cancer Screening
... decrease the risk of dying from cancer. Scientists study screening tests to find those with the fewest risks and ... of cancer, including ovarian cancer, or other conditions. Studies have also shown that ... Screening tests have risks. The risks of ovarian, fallopian tube, ...
Kaproth-Joslin, Katherine; Dogra, Vikram
2013-11-01
Hysterosalpingography is the gold standard in assessing the patency of the fallopian tubes, which is among the most common causes of female factor infertility, making this technique the most frequent first-choice imaging modality in the assessment of female infertility. Ultrasonography and magnetic resonance imaging are typically used for evaluation of indeterminate or complicated cases of female infertility and presurgical planning. Imaging also plays a role in the detection of the secondary causes of ovarian factor infertility, including endometriosis and polycystic ovarian syndrome. Copyright © 2013 Elsevier Inc. All rights reserved.
21 CFR 892.1660 - Non-image-intensified fluoroscopic x-ray system.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Non-image-intensified fluoroscopic x-ray system... fluoroscopic x-ray system. (a) Identification. A non-image-intensified fluoroscopic x-ray system is a device... of x-radiation into a visible image. This generic type of device may include signal analysis and...
21 CFR 892.1660 - Non-image-intensified fluoroscopic x-ray system.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Non-image-intensified fluoroscopic x-ray system... fluoroscopic x-ray system. (a) Identification. A non-image-intensified fluoroscopic x-ray system is a device... of x-radiation into a visible image. This generic type of device may include signal analysis and...
Semi-automated intra-operative fluoroscopy guidance for osteotomy and external-fixator.
Lin, Hong; Samchukov, Mikhail L; Birch, John G; Cherkashin, Alexander
2006-01-01
This paper outlines a semi-automated intra-operative fluoroscopy guidance and monitoring approach for osteotomy and external-fixator application in orthopedic surgery. Intra-operative Guidance module is one component of the "LegPerfect Suite" developed for assisting the surgical correction of lower extremity angular deformity. The Intra-operative Guidance module utilizes information from the preoperative surgical planning module as a guideline to overlay (register) its bone outline semi-automatically with the bone edge from the real-time fluoroscopic C-Arm X-Ray image in the operating room. In the registration process, scaling factor is obtained automatically through matching a fiducial template in the fluoroscopic image and a marker in the module. A triangle metal plate, placed on the operating table is used as fiducial template. The area of template image within the viewing area of the fluoroscopy machine is obtained by the image processing techniques such as edge detection and Hough transformation to extract the template from other objects in the fluoroscopy image. The area of fiducial template from fluoroscopic image is then compared with the area of the marker from the planning so as to obtain the scaling factor. After the scaling factor is obtained, the user can use simple operations by mouse to shift and rotate the preoperative planning to overlay the bone outline from planning with the bone edge from fluoroscopy image. In this way osteotomy levels and external fixator positioning on the limb can guided by the computerized preoperative plan.
Jwa, Seung Chik; Kamiyama, Shigeru; Takayama, Hisako; Tokunaga, Yoshimitsu; Sakumoto, Tetsuro; Higashi, Masahiro
Extrauterine choriocarcinoma in the fallopian tube is very rare and is often diagnosed and treated as an ectopic tubal pregnancy. A 34-year-old woman who initially became pregnant after infertility treatment using ovulation induction with clomiphene citrate and intrauterine insemination was later diagnosed with an extrauterine choriocarcinoma in the left fallopian tube. Because of suspected left ectopic tubal pregnancy based on ultrasonography findings and a high level of β-human chorionic gonadotropin (β-hCG; 7054.3 mIU/mL), the patient underwent diagnostic laparoscopy at a gestational age of 6 weeks. Left salpingectomy was performed based on the operative diagnosis of an ectopic tubal pregnancy. No signs of tubal rupture or leakage of contents from the fallopian tube were observed during the operation. Her serum β-hCG dropped to 10.3 mIU/mL at 15 days postoperatively. Histopathology demonstrated an extrauterine choriocarcinoma in the removed fallopian tube, and the patient was referred to a regional oncologic hospital to receive additional adjuvant chemotherapy. This case indicates that conservative treatment for ectopic pregnancy should be chosen carefully, and that histopathology diagnosis and appropriate β-hCG monitoring following treatment are important not only to diagnose persistent ectopic pregnancy, but also to rule out the possibility of a tubal choriocarcinoma. Copyright © 2017 AAGL. Published by Elsevier Inc. All rights reserved.
Correlation of clinical data with fallopian tube specimen immune cells and tissue culture capacity.
Ramraj, Satish Kumar; Smith, Katie M; Janakiram, Naveena B; Toal, Coralee; Raman, Ankita; Benbrook, Doris Mangiaracina
2018-06-01
Human fallopian tube fimbria secretory epithelial cells (hFTSECs) are considered an origin of ovarian cancer and methods for their culture from fallopian tube specimens have been reported. Our objective was to determine whether characteristics of the donors or surgeries were associated with the capacities of fimbria specimens to generate hFTSEC cultures or their immune profiles. There were no surgical complications attributable to fallopian tube removal. Attempts to establish primary hFTSEC cultures were successful in 37 of 55 specimens (67%). Success rates did not differ significantly between specimens grouped by patient or surgery characteristics. Established cultures could be revived after cryopreservation and none became contaminated with microorganisms. Two cultures evaluated for long term growth senesced between passages 10 and 15. M1 macrophages were the predominant cell type, while all other immune cells were present at much lower percentages. IL-10 and TGF-β exhibited opposing trends with M1 and M2 macrophages. Plasma IL-10 levels exhibited significant positive correlation with patient age. In conclusion, fallopian tube fimbria specimens exhibit a pro-inflammatory phenotype and can be used to provide a source of hFTSECs that can be cultured for a limited time regardless of the donor patient age or race, or the type of surgery performed. Copyright © 2018 Elsevier Ltd. All rights reserved.
Glycogen distribution in porcine fallopian tube epithelium during the estrus cycle.
Gregoraszczuk, E Ł; Cała, M; Witkowska, E
2000-01-01
Histochemical features of two different parts of the porcine Fallopian tube have been studied, with special reference to cyclic changes in the distribution of glycogen particles. Porcine Fallopian tubes were obtained from a local slaughterhouse. Slides were studied under light microscopy utilising histological and histochemical techniques. The most striking feature during the periovulatory stage of the estrus cycle was the occurrence of glycogen granules in the apical cytoplasm of epithelial cells in both the ampulla and isthmus of the Fallopian tubes. In the isthmus, cells containing numerous granules of polysaccharides aggregated into areas of different sizes were noted after ovulation. During the midluteal phase their number was minimal or were even absent. In the ampula typical extrusion of secretory granules and nuclei protruding into the tubal lumen was visible after ovulation. In the luteal phase a lot of nuclei protruded into the tubal lumen and some free in the lumen were noted. It is possible that glycogen in the preovulatory stage functions as a source of energy for ciliary movement and as a nourishment for the ovum. In the isthmus large number of aggregated glycogen particles was observed also after ovulation. In this stage of the cycle, numerous granules of polysaccharide aggregated in isthmus epithelium could be the major energy source for embriogenesis when the embryo travels down the Fallopian tubes, during the early cleavage stage.
Detection and Prevention of G-Induced Regional Atelectasis, Edema, and Hypoperfusion.
1975-12-01
Venous admixture in the pulmonary circulation of anesthetized dogs. J Appl Physiol 15:418 (1960). 13. Fowler, W. S., E. R. Cornish, Jr., and S. S...rebreathing method. J Clin Invest 38: 2073-2086 (1959). 18. Mead, J., and C. Collier. Relation of volume history of lungs to respiratory mechanics in... catheterization room for fluoroscopic studies, if these are required. A footrest (Fig. 1, point h), guided by stainless-steel tracks at the base of the table, is
2010-02-01
subsequent research has yielded additional in- sights. This review is a consensus report of current scien- tifi c data. Expected skin reactions for an...table has been cited and reproduced Essentials The minimum radiation dose n causing a specifi c type of reac- tion in the skin or hair is best...expressed in terms of a range of doses, rather than a single threshold dose. The times of onset and resolution n of specifi c radiation injuries
Ovarian, Fallopian Tube, and Primary Peritoneal Cancer Screening (PDQ®)—Patient Version
Ovarian, fallopian tube, or primary peritoneal cancer screening has not been shown to reduce the chance of dying from these cancers. Not all screening tests are helpful, and many have risks. Learn more the potential benefits and harms of screening in this expert-reviewed summary.
Ovarian, Fallopian Tube, and Primary Peritoneal Cancer—Patient Version
Ovarian epithelial cancer is the most common type of ovarian cancer. Cancer can also form at the end of the fallopian tube near the ovary or the peritoneum and spread to the ovary. Start here to find information on ovarian cancer treatment, causes and prevention, screening, research, and statistics.
2018-05-01
Fallopian Tube Cancer; Ovarian Clear Cell Cystadenocarcinoma; Ovarian Endometrioid Adenocarcinoma; Ovarian Mixed Epithelial Carcinoma; Ovarian Mucinous Cystadenocarcinoma; Ovarian Serous Cystadenocarcinoma; Ovarian Undifferentiated Adenocarcinoma; Peritoneal Cavity Cancer; Recurrent Ovarian Epithelial Cancer; Stage III Ovarian Epithelial Cancer; Stage IV Ovarian Epithelial Cancer
Treatment of Ovarian Epithelial, Fallopian, & Peritoneal Cancer (PDQ®)—Patient Version
Treatment of ovarian epithelial, fallopian tube, and primary peritoneal cancers depend on the stage. Most patients have surgery to remove as much of the tumor as possible. Learn about the different types of surgery, including hysterectomy and bilateral salpingo-oophorectomy, and other ovarian cancer treatment options.
2018-06-09
BRCA1 Gene Mutation; BRCA2 Gene Mutation; Folate Receptor Alpha Positive; Recurrent Fallopian Tube Carcinoma; Recurrent Ovarian Carcinoma; Recurrent Primary Peritoneal Carcinoma; Recurrent Uterine Corpus Carcinoma; Recurrent Uterine Serous Carcinoma; Recurrent Uterine Carcinosarcoma; Platinum Resistant Ovarian Cancer
2018-02-21
Estrogen Receptor Negative; HER2/Neu Negative; Progesterone Receptor Negative; Recurrent Breast Carcinoma; Recurrent Fallopian Tube Carcinoma; Recurrent Ovarian Carcinoma; Recurrent Primary Peritoneal Carcinoma; Recurrent Uterine Corpus Carcinoma; Triple-Negative Breast Carcinoma; Folate Receptor Alpha Positive
The fallopian canal: a comprehensive review and proposal of a new classification.
Mortazavi, M M; Latif, B; Verma, K; Adeeb, N; Deep, A; Griessenauer, C J; Tubbs, R S; Fukushima, T
2014-03-01
The facial nerve follows a complex course through the skull base. Understanding its anatomy is crucial during standard skull base approaches and resection of certain skull base tumors closely related to the nerve, especially, tumors at the cerebellopontine angle. Herein, we review the fallopian canal and its implications in surgical approaches to the skull base. Furthermore, we suggest a new classification. Based on the anatomy and literature, we propose that the meatal segment of the facial nerve be included as a component of the fallopian canal. A comprehensive knowledge of the course of the facial nerve is important to those who treat patients with pathology of or near this cranial nerve.
Salpingitis due to Entamoeba histolytica.
Calore, E E; Calore, N M P; Cavaliere, M J
2002-04-01
We describe the pathology of a unique case of Fallopian tube amebiasis, associated with hydrosalpinx, in a 21-year-old woman. She complained of lower abdominal pain, had a foul-smelling green vaginal discharge and fever during one week. There was a discrete increase in body temperature and a painful abdominal palpation at the lower right side, with signs of local peritoneal irritation. Pathological examination showed a marked dilatation of the fallopian tube and hydrosalpinx. Microscopic examination showed a poorly formed granuloma composed of large macrophages with many Entamoeba histolytica trophozoites inside the fallopian tube. Even though it is a rare disease the correct diagnosis of female genital tract amebiasis is of great importance for the indication of proper therapy.
Cysticercosis of the fallopian tube: histology and microanalysis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Abraham, J.L.; Spore, W.W.; Benirschke, K.
1982-07-01
The authors identified a degenerated, focally calcified cestode larva (cysticercus) in the fallopian tube of a 50-year-old woman with endometriosis. The physiologic reaction to the larva was minimal, with some focal granulomatous salpingitis. No other focus of infection was detected. The differential diagnosis included trophoblastic tissue, foreign material, and parasites. Scanning electron microscopy and x-ray microanalysis of the organism revealed concentration of iodine in the subcuticular connective tissue of the larva and confirmed the calcium phosphate composition of the calcareous corpuscles. The presumed source of the iodine was the continued exposure of the larva to an environment rich in iodidemore » secreted by the epithelium of the fallopian tube.« less
Ultrasound guided transrectal catheter drainage of pelvic collections.
Thakral, Anuj; Sundareyan, Ramaniwas; Kumar, Sheo; Arora, Divya
2015-01-01
The transrectal approach to draining deep-seated pelvic collections may be used to drain The transrectal approach to draining deep-seated pelvic collections may be used to drain intra-abdominal collections not reached by the transabdominal approach. We discuss 6 patients with such pelvic collections treated with transrectal drainage using catheter placement via Seldinger technique. Transrectal drainage helped achieve clinical and radiological resolution of pelvic collections in 6 and 5 of 6 cases, respectively. It simultaneously helped avoid injury to intervening bowel loops and neurovascular structures using real-time visualization of armamentarium used for drainage. Radiation exposure from fluoroscopic/CT guidance was avoided. Morbidity and costs incurred in surgical exploration were reduced using this much less invasive ultrasound guided transrectal catheter drainage of deep-seated pelvic collections.
2016-10-20
Fallopian Tube Carcinoma; Primary Peritoneal Carcinoma; Recurrent Borderline Ovarian Surface Epithelial-Stromal Tumor; Recurrent Ovarian Carcinoma; Stage III Borderline Ovarian Surface Epithelial-Stromal Tumor; Stage III Ovarian Cancer; Stage IV Borderline Ovarian Surface Epithelial-Stromal Tumor; Stage IV Ovarian Cancer
2017-10-18
Brenner Tumor; Fallopian Tube Cancer; Ovarian Clear Cell Cystadenocarcinoma; Ovarian Endometrioid Adenocarcinoma; Ovarian Mixed Epithelial Carcinoma; Ovarian Mucinous Cystadenocarcinoma; Ovarian Serous Cystadenocarcinoma; Ovarian Undifferentiated Adenocarcinoma; Primary Peritoneal Cavity Cancer; Recurrent Ovarian Epithelial Cancer
2014-12-29
Fatigue; Malignant Ovarian Mixed Epithelial Tumor; Neuropathy; Neurotoxicity Syndrome; Ovarian Brenner Tumor; Ovarian Clear Cell Cystadenocarcinoma; Ovarian Endometrioid Adenocarcinoma; Ovarian Mucinous Cystadenocarcinoma; Ovarian Serous Cystadenocarcinoma; Pain; Recurrent Fallopian Tube Carcinoma; Recurrent Ovarian Carcinoma; Recurrent Primary Peritoneal Carcinoma
2014-12-23
Malignant Ovarian Mixed Epithelial Tumor; Ovarian Brenner Tumor; Ovarian Clear Cell Cystadenocarcinoma; Ovarian Endometrioid Adenocarcinoma; Ovarian Mucinous Cystadenocarcinoma; Ovarian Serous Cystadenocarcinoma; Recurrent Fallopian Tube Carcinoma; Recurrent Ovarian Carcinoma; Recurrent Primary Peritoneal Carcinoma; Undifferentiated Ovarian Carcinoma
2018-06-04
Ovarian Brenner Tumor; Ovarian Carcinosarcoma; Ovarian Clear Cell Cystadenocarcinoma; Ovarian Endometrioid Adenocarcinoma; Ovarian Mucinous Cystadenocarcinoma; Ovarian Seromucinous Carcinoma; Ovarian Serous Cystadenocarcinoma; Ovarian Serous Surface Papillary Adenocarcinoma; Recurrent Fallopian Tube Carcinoma; Recurrent Ovarian Carcinoma; Recurrent Primary Peritoneal Carcinoma; Undifferentiated Ovarian Carcinoma
[Progress in research on reconstruction of fallopian tube after ligation].
Cheng, Q P
1984-05-01
An informative summary of foreign developments in microsurgical techniques used in post ligation fallopian tube reconstruction is discussed. In China, reconstructive surgery is limited to the traditional method of placing frames in the fallopian tube in order to prevent occlusion and/or anastomotic stenosis. The author maintains that this widely used technique is problematic due to frequent complications from injuries to the endosalpinx during implantation; moreover, frequent slippage of the commonly used polyvinyl frames also poses a number of problems. Since 1974, the authors have used type II catgut in suturing tissue following tubal-ampula anastomosis and fimbrial fistulation surgery. Polyvinyl tubing (inner diameter .5 mm) has also been used successfully in stenotic-stenotic and stenotic-interstial anastomotic surgery at Zhejiang Medical University (specific techniques and results are not disclosed). The author maintains that the wide discrepancy in the number of post surgery extrauterine pregnancies (0%-27% of cases) may be due to factors such as the severity and and extent of injuries to the fallopian tube during surgery, postoperative infections, and mucosal occlusion.
Kaido, Yoshitaka; Kikuchi, Akihiko; Kanasugi, Tomonobu; Fukushima, Akimune; Sugiyama, Toru
2013-01-01
We experienced an unreported rare case with an adnexal mass causing severe acute abdomen during pregnancy. A 30-year-old Japanese pregnant woman was transported to our hospital for her right lower abdominal pain at 30 weeks of gestation. Magnetic resonance imaging and ultrasound demonstrated a cyst measuring 3-4 cm in diameter adjacent to the right ovary, and a parovarian cyst was considered to be the most probable diagnosis. We strongly suspected torsion of the ovarian pedicle or fallopian tube in conjunction with her clinical symptoms. Laparotomy revealed that the elongated right fallopian tube accompanied by a paratubal cyst was coiling tightly 2.5 times round the right ovary, causing apparent congestion and enlargement of the right ovary. Soon after we released the congested right ovary from the coiling of the fallopian tube, the congestion subsided. The postoperative course was favorable, and pregnancy and delivery were uneventful. © 2012 The Authors. Journal of Obstetrics and Gynaecology Research © 2012 Japan Society of Obstetrics and Gynecology.
Ovarian epithelial, fallopian tube, and primary peritoneal cancers form in the same type of tissue and use the same staging system. Risk factors include family history and inherited gene mutations. Learn more about why ovarian cancers are often found at advanced stages and the tests to diagnose and stage the cancer.
HORIZONS: Understanding the Impact of Cancer Diagnosis and Treatment on Everyday Life
2018-04-09
Breast Cancer Female; Breast Neoplasm; Non-Hodgkin's B-cell Lymphoma; Non-Hodgkin's Lymphoma, Adult High Grade; NonHodgkin Lymphoma; Diffuse Large B Cell Lymphoma; Diffuse Large Cell Lymphoma, Adult; Ovarian Cancer; Ovarian Neoplasm; Endometrial Cancer; Endometrial Neoplasms; Cervical Cancer; Cervical Neoplasm; Primary Peritoneal Carcinoma; Fallopian Tube Cancer; Fallopian Tube Neoplasms; Vulvar Cancer; Vulvar Neoplasms
A method of percutaneous vertebroplasty under the guidance of two C-arm fluoroscopes
Xu, Ren-Jie; Yan, Yong-Qing; Chen, Guang-Xiang; Zou, Tian-Ming; Cai, Xiao-Qiang; Wang, Dong-Lai
2014-01-01
Objective: To compare the clinical application in the percutaneous vertebroplasty under the guidance of one or two C-arm fluoroscopes. Methods: One hundred forty three elderly patients with Osteoporotic vertebral compression fractures (OVCFs) underwent percutaneous vertebroplasty under the guidance of one or two C-arm fluoroscopes. The number of pulsed imagings, the time of operation and the incidence of cement leakage were recorded. Results: The average number of pulsed imagings was 16.00±1.58 vs 13.07±2.00 per patient under the guidance of one vs two C-arm fluoroscopes. The average time of operation was 48.42±5.00 minutes vs 39.70±7.42 minutes per patient under the guidance of one vs two C-arm fluoroscopes. The incidence of cement leakage was 20% vs 15.7% of the patients under the guidance of one vs two C-arm fluoroscopes. The differences in the number of pulsed imagings and the time of operation were statistically significant. The difference in incidence of cement leakage was not statistically significant. Conclusion: The two-fluoroscopic technique reduce the labor cost, the radiation, the time of operation and the operation risk. PMID:24772138
Turnbull, Hilary L; Akrivos, Nikolaos; Wemyss-Holden, Simon; Maiya, Balachandra; Duncan, Timothy J; Nieto, Joaquin J; Burbos, Nikolaos
2017-03-01
The aim of this study is to estimate the percentage of patients with metastatic ovarian, fallopian tube, and primary peritoneal cancer requiring ultra-radical surgery to achieve cytoreduction to less than 1 cm (optimal) or no macroscopic residual disease (complete). Perioperative data were collected prospectively on consecutive patients undergoing elective cytoreductive surgery for metastatic epithelial ovarian, fallopian tube, or primary peritoneal cancer at the Norfolk and Norwich University Hospital, a tertiary referral cancer centre in the United Kingdom from November 2012 to June 2016. Over a 42-month period, 135 consecutive patients underwent cytoreductive surgery for stage IIIC and IV ovarian, fallopian tube, or primary peritoneal cancer. The median age of the patients was 69 years. 47.4% of the patients underwent diaphragmatic peritonectomy and/or resection, 20% underwent splenectomy, 14.1% had excision of disease from porta hepatis and celiac axis, and 5.2% of the patients had gastrectomy. Cytoreduction to no macroscopic visible disease (complete) and to disease with greater tumour diameter of less than 1 cm (optimal) was achieved in 54.1 and 34.1% of the cases, respectively. Without incorporating surgical procedures in the upper abdomen ('ultra-radical'), the combined rate of complete and optimal cytoreduction would be only 33.3%. Up to 50.4% of the patients in this study required at least one surgical procedure classified as ultra-radical, emphasizing the importance of cytoreductive surgery in the upper abdomen in management of women with stage IIIC and IV ovarian, fallopian tube, and primary peritoneal cancer.
Fluoroscopy-Guided Endoscopic Removal of Foreign Bodies.
Kim, Junhwan; Ahn, Ji Yong; So, Seol; Lee, Mingee; Oh, Kyunghwan; Jung, Hwoon-Yong
2017-03-01
In most cases of ingested foreign bodies, endoscopy is the first treatment of choice. Moreover, emergency endoscopic removal is required for sharp and pointed foreign bodies such as animal or fish bones, food boluses, and button batteries due to the increased risks of perforation, obstruction, and bleeding. Here, we presented two cases that needed emergency endoscopic removal of foreign bodies without sufficient fasting time. Foreign bodies could not be visualized by endoscopy due to food residue; therefore, fluoroscopic imaging was utilized for endoscopic removal of foreign bodies in both cases.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bercu, Zachary L., E-mail: zachary.bercu@mountsinai.org; Sheth, Sachin B., E-mail: sachinsheth@gmail.com; Noor, Amir, E-mail: amir.noor@gmail.com
The creation of a transjugular intrahepatic portosystemic shunt (TIPS) is a critical procedure for the treatment of recurrent variceal bleeding and refractory ascites in the setting of portal hypertension. Chronic portal vein thrombosis remains a relative contraindication to conventional TIPS and options are limited in this scenario. Presented is a novel technique for management of refractory ascites in a patient with hepatitis C cirrhosis and chronic portal and superior mesenteric vein thrombosis secondary to schistosomiasis and lupus anticoagulant utilizing fluoroscopically guided percutaneous mesocaval shunt creation.
2017-07-24
Brenner Tumor; Fallopian Tube Cancer; Ovarian Clear Cell Cystadenocarcinoma; Ovarian Endometrioid Adenocarcinoma; Ovarian Mixed Epithelial Carcinoma; Ovarian Mucinous Cystadenocarcinoma; Ovarian Serous Cystadenocarcinoma; Ovarian Undifferentiated Adenocarcinoma; Peritoneal Cavity Cancer; Recurrent Ovarian Epithelial Cancer; Stage III Ovarian Epithelial Cancer; Stage IV Ovarian Epithelial Cancer
Mycoplasmateceae species are not found in Fallopian tubes of women with tubo-peritoneal infertility.
Costoya, Alberto; Morales, Francisco; Borda, Paula; Vargas, Renato; Fuhrer, Juan; Salgado, Nicole; Cárdenas, Hugo; Velasquez, Luis
2012-01-01
The role of mycoplasmas on the development and sequelae of pelvic inflammatory disease remains controversial. The objective of the present study is to correlate directly the presence of Mycoplasmateceae through polimerase chain reaction (PCR) determinations in cervix and Fallopian tubes of infertile patients with tubo-peritoneal factor diagnosed through laparoscopy. Thirty patients with tubo-peritoneal infertility and 30 normal fertile patients were included in the study; cervical samples and tubal flushings were obtained during laparoscopy. PCR determinations for the detection of genetic material of Mycoplasma genitalium, Mycoplasma hominis, Ureaplasma urealiticum, Neisseria gonorrhoeae, Chlamydia trachomatis, Trichomonas vaginalis in cervix and tubal flushings were performed. No Mycoplasmataceae species as "only" microorganisms were found in tubal flushings of tubo-peritoneal infertility patients, whereas three (10%) fertile patients with normal tubes were positive for mycoplasma presence. This difference was not significant (p = 0.237). Among the 30 patients suffering from tubal infertility diagnosed through laparoscopy, Mycoplasmatecae species were not detected in the Fallopian tubes by PCR determinations, while in normal tubes from fertile patients these and other microorganisms could be found without distorting tubal anatomy. Mycoplasmateceae species were not detected in Fallopian tubes of women with tubo-peritoneal infertility.
Ruptured ectopic pregnancy with contralateral adnexal torsion after spontaneous conception.
DiLuigi, Andrea J; Maier, Donald B; Benadiva, Claudio A
2008-11-01
To describe a case of ruptured ectopic pregnancy and contralateral adnexal torsion after spontaneous conception. Case report. Tertiary university medical center. A 23-year-old multiparous female with severe bilateral pelvic pain and a positive pregnancy test. Operative laparoscopy with detorsion of left adnexa, drainage of left ovarian hemorrhagic corpus luteum cyst, right salpingectomy, and dilation and curettage. Laparoscopy revealed a 5 cm hemorrhagic corpus luteum cyst of the left ovary, torsion of the left ovary and fallopian tube, and a ruptured right ampullary ectopic pregnancy. Normal perfusion of left ovary and fallopian tube after detorsion, resolution of left ovarian hemorrhagic corpus luteum cyst, patent left fallopian tube with chromopertubation, and successful removal of ectopic pregnancy. This is a unique case of adnexal torsion and contralateral ectopic pregnancy occurring after spontaneous conception.
21 CFR 1020.32 - Fluoroscopic equipment.
Code of Federal Regulations, 2011 CFR
2011-04-01
... information as required in § 1020.30(h). (h) Fluoroscopic irradiation time, display, and signal. (1)(i... irradiation time of the fluoroscopic tube. The maximum cumulative time of the timing device shall not exceed 5... preset cumulative irradiation-time. Such signal shall continue to sound while x-rays are produced until...
21 CFR 1020.32 - Fluoroscopic equipment.
Code of Federal Regulations, 2013 CFR
2013-04-01
... information as required in § 1020.30(h). (h) Fluoroscopic irradiation time, display, and signal. (1)(i... irradiation time of the fluoroscopic tube. The maximum cumulative time of the timing device shall not exceed 5... preset cumulative irradiation-time. Such signal shall continue to sound while x-rays are produced until...
21 CFR 1020.32 - Fluoroscopic equipment.
Code of Federal Regulations, 2014 CFR
2014-04-01
... information as required in § 1020.30(h). (h) Fluoroscopic irradiation time, display, and signal. (1)(i... irradiation time of the fluoroscopic tube. The maximum cumulative time of the timing device shall not exceed 5... preset cumulative irradiation-time. Such signal shall continue to sound while x-rays are produced until...
21 CFR 1020.32 - Fluoroscopic equipment.
Code of Federal Regulations, 2012 CFR
2012-04-01
... information as required in § 1020.30(h). (h) Fluoroscopic irradiation time, display, and signal. (1)(i... irradiation time of the fluoroscopic tube. The maximum cumulative time of the timing device shall not exceed 5... preset cumulative irradiation-time. Such signal shall continue to sound while x-rays are produced until...
Inspecting Pipe Radiographically Through Asbestos Insulation
NASA Technical Reports Server (NTRS)
Gianettino, David P.
1994-01-01
Welds between sections of insulated steampipe located and inspected radiographically. Unless need to repair defective weld, one avoids cost, time, and hazard of removing asbestos insulation. Enables inspectors to locate and evaluate nondestructively any weld in pipe system, without shutting down steam. Hidden weld joints first located by use of low-power fluoroscope, moved along pipe while technician observes fluoroscopic image. Low-energy x rays from fluoroscope penetrate insulation but not pipe. Weld bead appears in silhouette on fluoroscope screen. Technician then accurately marks weld sites on insulation for later inspection.
2018-06-20
Fallopian Tube Carcinoma; Primary Peritoneal Carcinoma; Stage I Ovarian Cancer; Stage IA Ovarian Cancer; Stage IB Ovarian Cancer; Stage IC Ovarian Cancer; Stage II Ovarian Cancer; Stage IIA Ovarian Cancer; Stage IIB Ovarian Cancer; Stage IIC Ovarian Cancer; Stage III Ovarian Cancer; Stage IIIA Ovarian Cancer; Stage IIIB Ovarian Cancer; Stage IIIC Ovarian Cancer; Stage IV Ovarian Cancer
2014-06-18
Brenner Tumor; Fallopian Tube Cancer; Ovarian Clear Cell Cystadenocarcinoma; Ovarian Endometrioid Adenocarcinoma; Ovarian Mixed Epithelial Carcinoma; Ovarian Mucinous Cystadenocarcinoma; Ovarian Serous Cystadenocarcinoma; Ovarian Undifferentiated Adenocarcinoma; Primary Peritoneal Cavity Cancer; Stage II Ovarian Epithelial Cancer; Stage III Ovarian Epithelial Cancer; Stage IV Ovarian Epithelial Cancer
Shigeta, S; Toyoshima, M; Kitatani, K; Ishibashi, M; Usui, T; Yaegashi, N
2016-07-07
Fallopian tubal epithelium is a candidate for the origin of high-grade serous ovarian cancer. Transferrin-containing follicular fluid and/or retrograde menstrual blood are possible risk factors for carcinogenesis. Accumulation of DNA double-strand breaks (DNA-DSBs) in the fallopian tubal epithelium is considered to play an important role in the development of cancer. However, the mechanisms by which DNA-DSBs accumulate have not yet been fully elucidated. The hydroxyl radical, which is produced in a Fenton reaction catalyzed by an iron ion, serves as a potent DNA-DSB-inducing molecule, raising the potential of an iron ion transporter of transferrin in the formation of DNA-DSBs. We studied the potential involvement of transferrin in DNA damage and the development of ovarian cancer. Treatment with transferrin facilitated the formation of histone 2AX phosphorylated at Serine 139 (γH2AX), which is known as a DNA-DSB marker, in human fallopian tube secretory epithelial cells and A2780 ovarian cancer cells. Knockdown of transferrin receptor 1 (TfR1), but not transferrin receptor 2, suppressed the transferrin uptake and consequent formation of γH2AX. As hydroxyl radicals in reactive oxygen species (ROS) are involved in DNA-DSBs, the formation of ROS was determined. Treatment with TfR1-specific small interference RNAs significantly diminished transferrin-induced formation of ROS. Moreover, TfR1-dependent uptake of transferrin was revealed to augment the formation of DNA-DSBs in the presence of hydrogen peroxide, which served as a substrate for the Fenton reaction. An ex vivo study with murine fallopian tubes further demonstrated that transferrin treatment introduced DNA-DSBs in the fallopian tubal epithelium. Collectively, these data suggested that the transferrin-TfR1 axis accounts for the induction of DNA-DSBs that potentially lead to DNA damage/genome instability. These findings also suggested that exposure to transferrin initiates and promotes the development of ovarian cancer by aiding the accumulation of DNA-DSBs in the fallopian tubal epithelium.
Zhu, Zhonglin; Li, Guoan
2013-01-01
Fluoroscopic image technique, using either a single image or dual images, has been widely applied to measure in vivo human knee joint kinematics. However, few studies have compared the advantages of using single and dual fluoroscopic images. Furthermore, due to the size limitation of the image intensifiers, it is possible that only a portion of the knee joint could be captured by the fluoroscopy during dynamic knee joint motion. In this paper, we presented a systematic evaluation of an automatic 2D–3D image matching method in reproducing spatial knee joint positions using either single or dual fluoroscopic image techniques. The data indicated that for the femur and tibia, their spatial positions could be determined with an accuracy and precision less than 0.2 mm in translation and less than 0.4° in orientation when dual fluoroscopic images were used. Using single fluoroscopic images, the method could produce satisfactory accuracy in joint positions in the imaging plane (average up to 0.5 mm in translation and 1.3° in rotation), but large variations along the out-plane direction (in average up to 4.0 mm in translation and 2.28 in rotation). The precision of using single fluoroscopic images to determine the actual knee positions was worse than its accuracy obtained. The data also indicated that when using dual fluoroscopic image technique, if the knee joint outlines in one image were incomplete by 80%, the algorithm could still reproduce the joint positions with high precisions. PMID:21806411
Dahm-Kähler, Pernilla; Borgfeldt, Christer; Holmberg, Erik; Staf, Christian; Falconer, Henrik; Bjurberg, Maria; Kjölhede, Preben; Rosenberg, Per; Stålberg, Karin; Högberg, Thomas; Åvall-Lundqvist, Elisabeth
2017-01-01
The aim of the study was to determine survival outcome in patients with serous cancer in the ovary, fallopian tube, peritoneum and of undesignated origin. Nation-wide population-based study of women≥18years with histologically verified non-uterine serous cancer, included in the Swedish Quality Registry for primary cancer of the ovary, fallopian tube and peritoneum diagnosed 2009-2013. Relative survival (RS) was estimated using the Ederer II method. Simple and multivariable analyses were estimated by Poisson regression models. Of 5627 women identified, 1246 (22%) had borderline tumors and 4381 had malignant tumors. In total, 2359 women had serous cancer; 71% originated in the ovary (OC), 9% in the fallopian tube (FTC), 9% in the peritoneum (PPC) and 11% at an undesignated primary site (UPS). Estimated RS at 5-years was 37%; for FTC 54%, 40% for OC, 34% for PPC and 13% for UPS. In multivariable regression analyses restricted to women who had undergone primary or interval debulking surgery for OC, FTC and PPC, site of origin was not independently associated with survival. Significant associations with worse survival were found for advanced stages (RR 2.63, P<0.001), moderate (RR 1.90, P<0.047) and poor differentiation (RR 2.20, P<0.009), neoadjuvant chemotherapy (RR1.33, P<0.022), residual tumor (RR 2.65, P<0.001) and platinum single (2.34, P<0.001) compared to platinum combination chemotherapy. Survival was poorer for serous cancer at UPS than for ovarian, fallopian tube and peritoneal cancer. Serous cancer at UPS needs to be addressed when reporting and comparing survival rates of ovarian cancer. Copyright © 2016 Elsevier Inc. All rights reserved.
Impact of Oophorectomy on Cancer Incidence and Mortality in Women With a BRCA1 or BRCA2 Mutation
Finch, Amy P.M.; Lubinski, Jan; Møller, Pål; Singer, Christian F.; Karlan, Beth; Senter, Leigha; Rosen, Barry; Maehle, Lovise; Ghadirian, Parviz; Cybulski, Cezary; Huzarski, Tomasz; Eisen, Andrea; Foulkes, William D.; Kim-Sing, Charmaine; Ainsworth, Peter; Tung, Nadine; Lynch, Henry T.; Neuhausen, Susan; Metcalfe, Kelly A.; Thompson, Islay; Murphy, Joan; Sun, Ping; Narod, Steven A.
2014-01-01
Purpose The purposes of this study were to estimate the reduction in risk of ovarian, fallopian tube, or peritoneal cancer in women with a BRCA1 or BRCA2 mutation after oophorectomy, by age of oophorectomy; to estimate the impact of prophylactic oophorectomy on all-cause mortality; and to estimate 5-year survival associated with clinically detected ovarian, occult, and peritoneal cancers diagnosed in the cohort. Patients and Methods Women with a BRCA1 or BRCA2 mutation were identified from an international registry; 5,783 women completed a baseline questionnaire and ≥ one follow-up questionnaires. Women were observed until either diagnosis of ovarian, fallopian tube, or peritoneal cancer, death, or date of most recent follow-up. Hazard ratios (HRs) for cancer incidence and all-cause mortality associated with oophorectomy were evaluated using time-dependent survival analyses. Results After an average follow-up period of 5.6 years, 186 women developed either ovarian (n = 132), fallopian (n = 22), or peritoneal (n = 32) cancer, of whom 68 have died. HR for ovarian, fallopian, or peritoneal cancer associated with bilateral oophorectomy was 0.20 (95% CI, 0.13 to 0.30; P < .001). Among women who had no history of cancer at baseline, HR for all-cause mortality to age 70 years associated with an oophorectomy was 0.23 (95% CI, 0.13 to 0.39; P < .001). Conclusion Preventive oophorectomy was associated with an 80% reduction in the risk of ovarian, fallopian tube, or peritoneal cancer in BRCA1 or BRCA2 carriers and a 77% reduction in all-cause mortality. PMID:24567435
Impact of oophorectomy on cancer incidence and mortality in women with a BRCA1 or BRCA2 mutation.
Finch, Amy P M; Lubinski, Jan; Møller, Pål; Singer, Christian F; Karlan, Beth; Senter, Leigha; Rosen, Barry; Maehle, Lovise; Ghadirian, Parviz; Cybulski, Cezary; Huzarski, Tomasz; Eisen, Andrea; Foulkes, William D; Kim-Sing, Charmaine; Ainsworth, Peter; Tung, Nadine; Lynch, Henry T; Neuhausen, Susan; Metcalfe, Kelly A; Thompson, Islay; Murphy, Joan; Sun, Ping; Narod, Steven A
2014-05-20
The purposes of this study were to estimate the reduction in risk of ovarian, fallopian tube, or peritoneal cancer in women with a BRCA1 or BRCA2 mutation after oophorectomy, by age of oophorectomy; to estimate the impact of prophylactic oophorectomy on all-cause mortality; and to estimate 5-year survival associated with clinically detected ovarian, occult, and peritoneal cancers diagnosed in the cohort. Women with a BRCA1 or BRCA2 mutation were identified from an international registry; 5,783 women completed a baseline questionnaire and ≥ one follow-up questionnaires. Women were observed until either diagnosis of ovarian, fallopian tube, or peritoneal cancer, death, or date of most recent follow-up. Hazard ratios (HRs) for cancer incidence and all-cause mortality associated with oophorectomy were evaluated using time-dependent survival analyses. After an average follow-up period of 5.6 years, 186 women developed either ovarian (n = 132), fallopian (n = 22), or peritoneal (n = 32) cancer, of whom 68 have died. HR for ovarian, fallopian, or peritoneal cancer associated with bilateral oophorectomy was 0.20 (95% CI, 0.13 to 0.30; P < .001). Among women who had no history of cancer at baseline, HR for all-cause mortality to age 70 years associated with an oophorectomy was 0.23 (95% CI, 0.13 to 0.39; P < .001). Preventive oophorectomy was associated with an 80% reduction in the risk of ovarian, fallopian tube, or peritoneal cancer in BRCA1 or BRCA2 carriers and a 77% reduction in all-cause mortality. © 2014 by American Society of Clinical Oncology.
Marquez, Rebecca T; Baggerly, Keith A; Patterson, Andrea P; Liu, Jinsong; Broaddus, Russell; Frumovitz, Michael; Atkinson, Edward N; Smith, David I; Hartmann, Lynn; Fishman, David; Berchuck, Andrew; Whitaker, Regina; Gershenson, David M; Mills, Gordon B; Bast, Robert C; Lu, Karen H
2005-09-01
Epithelial ovarian cancers are thought to arise from flattened epithelial cells that cover the ovarian surface or that line inclusion cysts. During malignant transformation, different histotypes arise that resemble epithelial cells from normal fallopian tube, endometrium, and intestine. This study compares gene expression in serous, endometrioid, clear cell, and mucinous ovarian cancers with that in the normal tissues that they resemble. Expression of 63,000 probe sets was measured in 50 ovarian cancers, in 5 pools of normal ovarian epithelial brushings, and in mucosal scrapings from 4 normal fallopian tube, 5 endometrium, and 4 colon specimens. Using rank-sum analysis, genes whose expressions best differentiated the ovarian cancer histotypes and normal ovarian epithelium were used to determine whether a correlation based on gene expression existed between ovarian cancer histotypes and the normal tissues they resemble. When compared with normal ovarian epithelial brushings, alterations in serous tumors correlated with those in normal fallopian tube (P = 0.0042) but not in other normal tissues. Similarly, mucinous cancers correlated with those in normal colonic mucosa (P = 0.0003), and both endometrioid and clear cell histotypes correlated with changes in normal endometrium (P = 0.0172 and 0.0002, respectively). Mucinous cancers displayed the greatest number of alterations in gene expression when compared with normal ovarian epithelial cells. Studies at a molecular level show distinct expression profiles of different histologies of ovarian cancer and support the long-held belief that histotypes of ovarian cancers come to resemble normal fallopian tube, endometrial, and colonic epithelium. Several potential molecular markers for mucinous ovarian cancers have been identified.
Heilmaier, Christina; Kara, Levent; Zuber, Niklaus; Berthold, Christian; Weishaupt, Dominik
2016-04-01
To determine the effect on patient radiation exposure of the combined use of a patient dose monitoring system and real-time occupational dose monitoring during fluoroscopically guided interventions (FGIs). Patient radiation exposure, in terms of the kerma area product (KAP; Gy ∙ cm(2)), was measured in period 1 with a patient dose monitoring system, and a real-time occupational dose monitoring system was additionally applied in period 2. Mean/median KAP in 19 different types of FGIs was analyzed in both periods for two experienced interventional radiologists combined as well as individually. Patient dose and occupational dose were correlated, applying Pearson and Spearman correlation coefficients. Although FGIs were similar in numbers and types over both periods, a substantial decrease was found for period 2 in total mean ± SD/median KAP for both operators together (period 1, 47 Gy ∙ cm(2) ± 67/41 Gy ∙ cm(2); period 2, 37 Gy ∙ cm(2) ± 69/34 Gy ∙ cm(2)) as well as for each individual operator (for all, P < .05). Overall, KAP declined considerably in 15 of 19 types of FGIs in period 2. Mean accumulated dose per intervention was 4.6 µSv, and mean dose rate was 0.24 mSv/h. There was a strong positive correlation between patient and occupational dose (r = 0.88). Combined use of a patient dose monitoring system and a real-time occupational dose monitoring system in FGIs significantly lessens patient and operator doses. Copyright © 2016 SIR. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Gong, Ren Hui; Jenkins, Brad; Sze, Raymond W.; Yaniv, Ziv
2014-03-01
The skills required for obtaining informative x-ray fluoroscopy images are currently acquired while trainees provide clinical care. As a consequence, trainees and patients are exposed to higher doses of radiation. Use of simulation has the potential to reduce this radiation exposure by enabling trainees to improve their skills in a safe environment prior to treating patients. We describe a low cost, high fidelity, fluoroscopy simulation system. Our system enables operators to practice their skills using the clinical device and simulated x-rays of a virtual patient. The patient is represented using a set of temporal Computed Tomography (CT) images, corresponding to the underlying dynamic processes. Simulated x-ray images, digitally reconstructed radiographs (DRRs), are generated from the CTs using ray-casting with customizable machine specific imaging parameters. To establish the spatial relationship between the CT and the fluoroscopy device, the CT is virtually attached to a patient phantom and a web camera is used to track the phantom's pose. The camera is mounted on the fluoroscope's intensifier and the relationship between it and the x-ray source is obtained via calibration. To control image acquisition the operator moves the fluoroscope as in normal operation mode. Control of zoom, collimation and image save is done using a keypad mounted alongside the device's control panel. Implementation is based on the Image-Guided Surgery Toolkit (IGSTK), and the use of the graphics processing unit (GPU) for accelerated image generation. Our system was evaluated by 11 clinicians and was found to be sufficiently realistic for training purposes.
Deep architecture neural network-based real-time image processing for image-guided radiotherapy.
Mori, Shinichiro
2017-08-01
To develop real-time image processing for image-guided radiotherapy, we evaluated several neural network models for use with different imaging modalities, including X-ray fluoroscopic image denoising. Setup images of prostate cancer patients were acquired with two oblique X-ray fluoroscopic units. Two types of residual network were designed: a convolutional autoencoder (rCAE) and a convolutional neural network (rCNN). We changed the convolutional kernel size and number of convolutional layers for both networks, and the number of pooling and upsampling layers for rCAE. The ground-truth image was applied to the contrast-limited adaptive histogram equalization (CLAHE) method of image processing. Network models were trained to keep the quality of the output image close to that of the ground-truth image from the input image without image processing. For image denoising evaluation, noisy input images were used for the training. More than 6 convolutional layers with convolutional kernels >5×5 improved image quality. However, this did not allow real-time imaging. After applying a pair of pooling and upsampling layers to both networks, rCAEs with >3 convolutions each and rCNNs with >12 convolutions with a pair of pooling and upsampling layers achieved real-time processing at 30 frames per second (fps) with acceptable image quality. Use of our suggested network achieved real-time image processing for contrast enhancement and image denoising by the use of a conventional modern personal computer. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
Momin, Eric N; Recinos, Pablo F; Coon, Alexander L; Rigamonti, Daniele
2010-06-01
Ventriculoatrial (VA) shunting is commonly used to treat hydrocephalus when ventriculoperitoneal shunting has failed. Placement of a VA shunt in patients with narrowing or occlusion of the central veins presents considerable difficulty because few imaging modalities exist to safely and reliably insert a guidewire or atrial catheter past the occlusion. We report the use of intraoperative venography to guide the placement of the distal portion of a VA shunt in a patient with a valve blocking the left brachiocephalic vein. A 42-year-old man with pseudotumor cerebri and a left ventriculoperitoneal shunt presented with severe headaches. He was diagnosed with partial distal shunt obstruction. Because of a history of failed attempts at ventriculoperitoneal shunting, conversion to a VA shunt via the left internal jugular vein was planned. Surgery was performed by using the standard technique until resistance was encountered when inserting a guidewire into the internal jugular vein. Intraoperative venography of the central veins was performed, which showed a large valve blocking progression of the guidewire in the left brachiocephalic vein. Using fluoroscopic guidance, a 0.035-inch guidewire was successfully directed through the vein past the obstruction and exchanged for a peel-away introducer. The distal shunt catheter was then inserted, and the correct position in the atrium was confirmed fluoroscopically. When obstruction of the central veins is found during a VA shunting procedure, intraoperative venography is a useful method to aid in the placement of the atrial catheter through the central veins.
Sugand, Kapil; Wescott, Robert A; Carrington, Richard; Hart, Alister; Van Duren, Bernard H
2018-05-10
Background and purpose - Simulation is an adjunct to surgical education. However, nothing can accurately simulate fluoroscopic procedures in orthopedic trauma. Current options for training with fluoroscopy are either intraoperative, which risks radiation, or use of expensive and unrealistic virtual reality simulators. We introduce FluoroSim, an inexpensive digital fluoroscopy simulator without the need for radiation. Patients and methods - This was a multicenter study with 26 surgeons in which everyone completed 1 attempt at inserting a guide-wire into a femoral dry bone using surgical equipment and FluoroSim. 5 objective performance metrics were recorded in real-time to assess construct validity. The surgeons were categorized based on the number of dynamic hip screws (DHS) performed: novices (< 10), intermediates (10-39) and experts (≥ 40). A 7-point Likert scale questionnaire assessed the face and content validity of FluoroSim. Results - Construct validity was present for 2 clinically validated metrics in DHS surgery. Experts and intermediates statistically significantly outperformed novices for tip-apex distance and for cut-out rate. Novices took the least number of radiographs. Face and content validity were also observed. Interpretation - FluoroSim discriminated between novice and intermediate or expert surgeons based on tip-apex distance and cut-out rate while demonstrating face and content validity. FluoroSim provides a useful adjunct to orthopedic training. Our findings concur with results from studies using other simulation modalities. FluoroSim can be implemented for education easily and cheaply away from theater in a safe and controlled environment.
Zhao, Kristin D.; Ben-Abraham, Ephraim I.; Magnuson, Dixon J.; Camp, Jon J.; Berglund, Lawrence J.; An, Kai-Nan; Bronfort, Gert; Gay, Ralph E.
2016-01-01
Spine intersegmental motion parameters and the resultant regional patterns may be useful for biomechanical classification of low back pain (LBP) as well as assessing the appropriate intervention strategy. Because of its availability and reasonable cost, two-dimensional (2D) fluoroscopy has great potential as a diagnostic and evaluative tool. However, the technique of quantifying intervertebral motion in the lumbar spine must be validated, and the sensitivity assessed. The purpose of this investigation was to (1) compare synchronous fluoroscopic and optoelectronic measures of intervertebral rotations during dynamic flexion–extension movements in vitro and (2) assess the effect of C-arm rotation to simulate off-axis patient alignment on intervertebral kinematics measures. Six cadaveric lumbar–sacrum specimens were dissected, and active marker optoelectronic sensors were rigidly attached to the bodies of L2–S1. Fluoroscopic sequences and optoelectronic kinematic data (0.15-mm linear, 0.17–0.20 deg rotational, accuracy) were obtained simultaneously. After images were obtained in a true sagittal plane, the image receptor was rotated in 5 deg increments (posterior oblique angulations) from 5 deg to 15 deg. Quantitative motion analysis (qma) software was used to determine the intersegmental rotations from the fluoroscopic images. The mean absolute rotation differences between optoelectronic values and dynamic fluoroscopic values were less than 0.5 deg for all the motion segments at each off-axis fluoroscopic rotation and were not significantly different (P > 0.05) for any of the off-axis rotations of the fluoroscope. Small misalignments of the lumbar spine relative to the fluoroscope did not introduce measurement variation in relative segmental rotations greater than that observed when the spine and fluoroscope were perpendicular to each other, suggesting that fluoroscopic measures of relative segmental rotation during flexion–extension are likely robust, even when patient alignment is not perfect. PMID:26974192
Zhao, Kristin D; Ben-Abraham, Ephraim I; Magnuson, Dixon J; Camp, Jon J; Berglund, Lawrence J; An, Kai-Nan; Bronfort, Gert; Gay, Ralph E
2016-05-01
Spine intersegmental motion parameters and the resultant regional patterns may be useful for biomechanical classification of low back pain (LBP) as well as assessing the appropriate intervention strategy. Because of its availability and reasonable cost, two-dimensional (2D) fluoroscopy has great potential as a diagnostic and evaluative tool. However, the technique of quantifying intervertebral motion in the lumbar spine must be validated, and the sensitivity assessed. The purpose of this investigation was to (1) compare synchronous fluoroscopic and optoelectronic measures of intervertebral rotations during dynamic flexion-extension movements in vitro and (2) assess the effect of C-arm rotation to simulate off-axis patient alignment on intervertebral kinematics measures. Six cadaveric lumbar-sacrum specimens were dissected, and active marker optoelectronic sensors were rigidly attached to the bodies of L2-S1. Fluoroscopic sequences and optoelectronic kinematic data (0.15-mm linear, 0.17-0.20 deg rotational, accuracy) were obtained simultaneously. After images were obtained in a true sagittal plane, the image receptor was rotated in 5 deg increments (posterior oblique angulations) from 5 deg to 15 deg. Quantitative motion analysis (qma) software was used to determine the intersegmental rotations from the fluoroscopic images. The mean absolute rotation differences between optoelectronic values and dynamic fluoroscopic values were less than 0.5 deg for all the motion segments at each off-axis fluoroscopic rotation and were not significantly different (P > 0.05) for any of the off-axis rotations of the fluoroscope. Small misalignments of the lumbar spine relative to the fluoroscope did not introduce measurement variation in relative segmental rotations greater than that observed when the spine and fluoroscope were perpendicular to each other, suggesting that fluoroscopic measures of relative segmental rotation during flexion-extension are likely robust, even when patient alignment is not perfect.
Saini, Pradeep; Faridi, M S; Agarwal, Nitin; Gupta, Arun; Kaur, Navneet
2012-04-01
Placement of a drain following abdominal surgery is common despite a lack of convincing evidence in the current literature to support this practice. The use of intra-abdominal drain is associated with many potential and serious complications. We report a drain site evisceration of the right fallopian tube after the removal of an intra-abdominal drain. The drain was placed in the right iliac fossa in a patient who underwent a lower segment Caesarean section (LSCS) for meconium liquor with fetal distress. The Pfannenstiel incision made for LSCS was reopened and the protruding inflamed fimbrial end of the right fallopian tube was excised. The patient made an uneventful recovery. Routine intra-abdominal prophylactic drain following an abdominal surgery including LSCS should be discouraged.
Thompson, Bradley F; Pingree, Matthew J; Qu, Wenchun; Murthy, Naveen S; Lachman, Nirusha; Hurdle, Mark Friedrich
2018-04-01
Ultrasound is rarely used for guiding lumbosacral epidural steroid injections due to its technical limitations. For example, sonographic imaging lacks the ability to confirm epidural spread and identify vascular uptake. The perceived risk that these limitations pose to human subjects has precluded any large scale clinical trials to date. To compare the accuracy of ultrasound versus fluoroscopic guidance for first sacral transforaminal epidural injections. Cadaveric comparative study using dichotomous outcomes. A fluoroscopy suite and anatomic laboratory at an academic medical center. Four unembalmed adult human cadavers with no history of spinal surgery. Eight sites were injected twice by one interventionalist, using fluoroscopic and ultrasound guidance. In the fluoroscopy arm, contrast spread was assessed using computed tomography. In the ultrasound arm, latex spread was assessed using gross anatomic dissection. Any visible evidence of epidural spread constituted a positive result. Comparison of the success of obtaining epidural contrast flow was the primary outcome measure. Secondary outcome measures included average duration, rate of intravascular uptake, and quantity of intravascular uptake. All injections performed in both the ultrasound arm and the fluoroscopy arm had positive epidural spread. The average duration was 3.03 minutes with fluoroscopy and 4.76 minutes with ultrasound. The rate of intravascular uptake was 37.5% with fluoroscopy and 50% with ultrasound. Within the ultrasound arm, greater intravascular spread and duration variability were recorded. Although ultrasonography can provide reliable image guidance for cannulating the first sacral foramen in cadavers, it would have limited clinical utility due to its inability to visualize relevant neurovascular structures deep to the osseus roof and exclude intravascular uptake. IV. Copyright © 2018 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.
Yu, Robinson K.; Ghodadra, Anish; Agarwal, Vikas
2016-01-01
Background Lumbar transforaminal epidural steroid injection is a common and effective tool for managing lumbar radicular pain, although accidental intravascular injection can rarely result in paralysis. The purpose of this study is to determine the safest needle tip position for computed tomography (CT)-guided lumbar transforaminal epidural steroid injections as determined by incidence of intravascular injection. Methods Three radiologists, in consensus, reviewed procedural imaging for consecutive CT-fluoroscopic lumbar transforaminal epidural steroid injections performed during a 16-month period. Intravascular injections were identified and categorized by needle tip position, vessel type injected, intravascular injection volume and procedural phase containing the intravascular injection. Pearson chi-square and logistic regression testing were used to assess differences between groups, as appropriate. Results Intravascular injections occurred in 9% (52/606) of injections. The intravascular injection rate was significantly lower (P<0.001) for extraforaminal needle position (0%, 0/109) compared to junctional (8%, 27/319) and foraminal (14%, 25/178) needle tip positions. Of the intravascular injections, 4% (2/52) were likely arterial, 35% (18/52) were likely venous, and 62% (32/52) were indeterminate for vessel type injected. 46% (24/52) of intravascular injections were large volume, 33% (17/52) were small volume, and 21% (11/52) were trace volume. 56% (29/52) of intravascular injections occurred with the contrast trial dose, 29% (15/52) with the steroid/analgesic cocktail, and 15% (8/52) with both. Conclusions An extraforaminal needle position for CT-fluoroscopic lumbar transforaminal epidural steroid injections decreases the risk of intravascular injection and therefore may be safer than other needle tip positions. PMID:28097241
Evaluation of low-dose limits in 3D-2D rigid registration for surgical guidance
NASA Astrophysics Data System (ADS)
Uneri, A.; Wang, A. S.; Otake, Y.; Kleinszig, G.; Vogt, S.; Khanna, A. J.; Gallia, G. L.; Gokaslan, Z. L.; Siewerdsen, J. H.
2014-09-01
An algorithm for intensity-based 3D-2D registration of CT and C-arm fluoroscopy is evaluated for use in surgical guidance, specifically considering the low-dose limits of the fluoroscopic x-ray projections. The registration method is based on a framework using the covariance matrix adaptation evolution strategy (CMA-ES) to identify the 3D patient pose that maximizes the gradient information similarity metric. Registration performance was evaluated in an anthropomorphic head phantom emulating intracranial neurosurgery, using target registration error (TRE) to characterize accuracy and robustness in terms of 95% confidence upper bound in comparison to that of an infrared surgical tracking system. Three clinical scenarios were considered: (1) single-view image + guidance, wherein a single x-ray projection is used for visualization and 3D-2D guidance; (2) dual-view image + guidance, wherein one projection is acquired for visualization, combined with a second (lower-dose) projection acquired at a different C-arm angle for 3D-2D guidance; and (3) dual-view guidance, wherein both projections are acquired at low dose for the purpose of 3D-2D guidance alone (not visualization). In each case, registration accuracy was evaluated as a function of the entrance surface dose associated with the projection view(s). Results indicate that images acquired at a dose as low as 4 μGy (approximately one-tenth the dose of a typical fluoroscopic frame) were sufficient to provide TRE comparable or superior to that of conventional surgical tracking, allowing 3D-2D guidance at a level of dose that is at most 10% greater than conventional fluoroscopy (scenario #2) and potentially reducing the dose to approximately 20% of the level in a conventional fluoroscopically guided procedure (scenario #3).
Sharma's Python Sign: A New Tubal Sign in Female Genital Tuberculosis.
Sharma, Jai Bhagwan
2016-01-01
Female genital tuberculosis (FGTB) is an important cause of infertility in developing countries. Various type of TB salpingitis can be endosalpingitis, exosalpingitis, interstitial TB salpingitis, and salpingitis isthmica nodosa. The fallopian tubes are thickened enlarged and tortuous. Unilateral or bilateral hydrosalpinx or pyosalpinx may be formed. A new sign python sign is presented in which fallopian tube looks like a blue python on dye testing in FGTB.
Microsurgical techniques of anastomosis of the fallopian tubes.
Smith, R N; Minkler, D
1978-01-01
Microsurgical techniques of anastomosis of the fallopian tubes have been studied. This paper considers the present state of the art of sterilization reversal, the training and equipment required, the potential for the diffusion of knowledge concerning reversal techniques, and the implication of current research in reversibility of sterilization for the practicing gynecologist. A preoperative study should be done on any candidate for a procedure to restore patency to the fallopian tubes to rule out other possible causes of infertility. Also, preoperative counseling should include both partners. The operating microscope offers a great advantage in the repair of several types of tubal obstruction. Midsegment end-to-end anastomosis is carried out by 1st injecting a dye into the cavity to locate the area of obstruction. The area is excised using microdissection and the fallopian tube checked for patency with the dye solution. Anastomosis is accomplished by opposing the miscularis of the tube, avoiding the mucosa. 4 sutures are usually adequate for closure. Most feel that postoperative hydrotubation is of some value in monitoring tubal patency. An organized training program in a microsurgical laboratory is the prefered way for learning the techniques. Long-term results of the microsurgical techniques for tubal anastomosis are encouraging and represent an improvement over macroscopic techniques previously reported.
NASA Astrophysics Data System (ADS)
Bergeron, Jeffrey A.; Eskey, Cliff J.; Attawia, Mohammed; Patel, Samit J.; Ryan, Thomas P.; Pellegrino, Richard; Sutton, Jeffrey; Crombie, John; Paul, B. T.; Hoopes, P. J.
2005-04-01
Pathologic involvement of the basivertebral nerve, an intraosseous vertebral nerve found in humans and most mammalian species, may play a role in some forms of back pain. This study was designed to assess the feasibility and effects of the percutaneous delivery of radiofrequency (RF) energy to thermally ablate the basivertebral nerve in the lumbar vertebrae of mature sheep. Using fluoroscopic guidance, a RF bipolar device was placed and a thermal dose delivered to lumbar vertebral bodies in sheep. Post-treatment assessment included multiple magnetic resonance imaging (MRI) techniques and computed tomography (CT). These data were analyzed and correlated to histopathology and morphometry findings to describe the cellular and boney structural changes resulting from the treatment. Imaging modalities MRI and CT can be implemented to non-invasively describe treatment region and volume, marrow cellular effects, and bone density alterations immediately following RF treatment and during convalescence. Such imaging can be utilized to assess treatment effects and refine the thermal dose to vertebral body volume ratio used in treatment planning. This information will be used to improve the therapeutic ratio and develop a treatment protocol for human applications.
Spine epidural and sacroiliac joints injections--when and how to perform.
D'Orazio, Federico; Gregori, Lorenzo Maria; Gallucci, Massimo
2015-05-01
To review the state-of-the-art of image-guided techniques used to treat painful syndromes of the lower back, their indications, how they should be performed, their related risks and the expected results. We describe the actual standards about image-guided infiltrative therapies both on spine and on sacroiliac joints. Both spinal epidural and sacroiliac injections appear useful in a large percentage of treated patients to get control of the perceived pain. Performing these therapies under CT or fluoroscopic guidance is the best and safest way to obtain satisfactory results because it is possible to target the use of drugs directly to the involved painful structures. Image-guided injections of the epidural space and of the sacroiliac joints are effective techniques for the treatment of pain; their effectiveness is sometimes not lasting for long periods of time but considering the low associated risk when performed by trained personnel, they can be easily repeated. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Nagai, Yuichi; Kitagawa, Mayumi; Torii, Jun; Iwase, Takumi; Aso, Tomohiko; Ihara, Kanyu; Fujikawa, Mari; Takeuchi, Yumiko; Suzuki, Katsumi; Ishiguro, Takashi; Hara, Akio
2014-03-01
Recently, the double contrast technique in a gastrointestinal examination and the transbronchial lung biopsy in an examination for the respiratory system [1-3] have made a remarkable progress. Especially in the transbronchial lung biopsy, better quality of x-ray fluoroscopic images is requested because this examination is performed under a guidance of x-ray fluoroscopic images. On the other hand, various image processing methods [4] for x-ray fluoroscopic images have been developed as an x-ray system with a flat panel detector [5-7] is widely used. A recursive filtering is an effective method to reduce a random noise in x-ray fluoroscopic images. However it has a limitation for its effectiveness of a noise reduction in case of a moving object exists in x-ray fluoroscopic images because the recursive filtering is a noise reduction method by adding last few images. After recursive filtering a residual signal was produced if a moving object existed in x-ray images, and this residual signal disturbed a smooth procedure of the examinations. To improve this situation, new noise reduction method has been developed. The Adaptive Noise Reduction [ANR] is the brand-new noise reduction technique which can be reduced only a noise regardless of the moving object in x-ray fluoroscopic images. Therefore the ANR is a very suitable noise reduction method for the transbronchial lung biopsy under a guidance of x-ray fluoroscopic images because the residual signal caused of the moving object in x-ray fluoroscopic images is never produced after the ANR. In this paper, we will explain an advantage of the ANR by comparing of a performance between the ANR images and the conventional recursive filtering images.
Towards fluoroscopic respiratory gating for lung tumours without radiopaque markers
NASA Astrophysics Data System (ADS)
Berbeco, Ross I.; Mostafavi, Hassan; Sharp, Gregory C.; Jiang, Steve B.
2005-10-01
Due to the risk of pneumothorax, many clinicians are reluctant to implant radiopaque markers within patients' lungs for the purpose of radiographic or fluoroscopic tumour localization. We propose a method of gated therapy using fluoroscopic information without the implantation of radiopaque markers. The method presented here does not rely on any external motion signal either. Breathing phase information is found by analysing the fluoroscopic intensity fluctuations in the lung. As the lungs fill/empty, the radiological pathlength through them shortens/lengthens, giving brighter/darker fluoroscopic intensities. The phase information is combined with motion-enhanced template matching to turn the beam on when the tumour is in the desired location. A study based on patient data is presented to demonstrate the feasibility of this procedure. The resulting beam-on pattern is similar to that produced by an external gating system. The only discrepancies occur briefly and at the gate edges.
Aspergillus meningitis and discitis from low-back procedures in an immunocompetent patient.
Kolbe, A B Larson; McKinney, A M; Kendi, A Tuba Karagulle; Misselt, D
2007-07-01
We present a case of an immunocompetent patient who developed Aspergillus meningitis, subsequent to discitis, presumed to be from an epidural steroid injection. Magnetic resonance imaging (MRI) of the lumbar spine confirmed the diagnosis of discitis. Fluoroscopic-guided aspiration of the disc showed growth of Aspergillus fumigatus. MRI of the brain revealed involvement of the right third cranial nerve. Repeat MRIs demonstrated multiple leptomeningeal masses consistent with granulomatous meningitis. Meningitis is a rare complication of discitis, discogram, or epidural steroid injection. Aspergillus usually only infects immunocompromised patients, but rarely can affect immunocompetent patients.
Editorial: ERCP-Related Radiation Cataractogenesis: Is It Time to Be Concerned?
Mekaroonkamol, Parit; Keilin, Steven
2017-05-01
With the growing number of fluoroscopic guided endoscopic procedures, radiation-related risk needs to be further assessed. Recent evidence indicates that radiation cataractogenesis occurs at a lower dose threshold than previously believed. While body aprons and thyroid shields are well-established standard protection during fluoroscopy, ocular safety and the use of protective eyewear are not as well defined. This prospective study answered two important questions: Does the standard body dosimeter provide an accurate ocular dosimetry? And what is the time of fluoroscopy needed to warrant using lens protection? It also raises the question whether current guidelines need to be updated.
Primary Tumours of the Fallopian Tube
Ross, Winifred M.
1967-01-01
Nine patients with primary tumour of the fallopian tube were seen at the Royal Marsden Hospital and Chelsea Hospital for Women, London. All the tumours except one were adenocarcinomas. Histologically, the exception resembled an adenomatoid tumour, but was clinically malignant and had some features of a hemangiopericytoma. Postoperative irradiation did not increase survival. The only five-year survivor was a patient who received radiation therapy for a late local recurrence. ImagesFig. 1Fig. 2 PMID:5334754
Sharma's Python Sign: A New Tubal Sign in Female Genital Tuberculosis
Sharma, Jai Bhagwan
2016-01-01
Female genital tuberculosis (FGTB) is an important cause of infertility in developing countries. Various type of TB salpingitis can be endosalpingitis, exosalpingitis, interstitial TB salpingitis, and salpingitis isthmica nodosa. The fallopian tubes are thickened enlarged and tortuous. Unilateral or bilateral hydrosalpinx or pyosalpinx may be formed. A new sign python sign is presented in which fallopian tube looks like a blue python on dye testing in FGTB. PMID:27365923
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dhou, S; Cai, W; Hurwitz, M
Purpose: We develop a method to generate time varying volumetric images (3D fluoroscopic images) using patient-specific motion models derived from four-dimensional cone-beam CT (4DCBCT). Methods: Motion models are derived by selecting one 4DCBCT phase as a reference image, and registering the remaining images to it. Principal component analysis (PCA) is performed on the resultant displacement vector fields (DVFs) to create a reduced set of PCA eigenvectors that capture the majority of respiratory motion. 3D fluoroscopic images are generated by optimizing the weights of the PCA eigenvectors iteratively through comparison of measured cone-beam projections and simulated projections generated from the motionmore » model. This method was applied to images from five lung-cancer patients. The spatial accuracy of this method is evaluated by comparing landmark positions in the 3D fluoroscopic images to manually defined ground truth positions in the patient cone-beam projections. Results: 4DCBCT motion models were shown to accurately generate 3D fluoroscopic images when the patient cone-beam projections contained clearly visible structures moving with respiration (e.g., the diaphragm). When no moving anatomical structure was clearly visible in the projections, the 3D fluoroscopic images generated did not capture breathing deformations, and reverted to the reference image. For the subset of 3D fluoroscopic images generated from projections with visibly moving anatomy, the average tumor localization error and the 95th percentile were 1.6 mm and 3.1 mm respectively. Conclusion: This study showed that 4DCBCT-based 3D fluoroscopic images can accurately capture respiratory deformations in a patient dataset, so long as the cone-beam projections used contain visible structures that move with respiration. For clinical implementation of 3D fluoroscopic imaging for treatment verification, an imaging field of view (FOV) that contains visible structures moving with respiration should be selected. If no other appropriate structures are visible, the images should include the diaphragm. This project was supported, in part, through a Master Research Agreement with Varian Medical Systems, Inc, Palo Alto, CA.« less
Occupational Health Risks in Cardiac Catheterization Laboratory Workers.
Andreassi, Maria Grazia; Piccaluga, Emanuela; Guagliumi, Giulio; Del Greco, Maurizio; Gaita, Fiorenzo; Picano, Eugenio
2016-04-01
Orthopedic strain and radiation exposure are recognized risk factors in personnel staff performing fluoroscopically guided cardiovascular procedures. However, the potential occupational health effects are still unclear. The purpose of this study was to examine the prevalence of health problems among personnel staff working in interventional cardiology/cardiac electrophysiology and correlate them with the length of occupational radiation exposure. We used a self-administered questionnaire to collect demographic information, work-related information, lifestyle-confounding factors, all current medications, and health status. A total number of 746 questionnaires were properly filled comprising 466 exposed staff (281 males; 44±9 years) and 280 unexposed subjects (179 males; 43±7years). Exposed personnel included 218 interventional cardiologists and electrophysiologists (168 males; 46±9 years); 191 nurses (76 males; 42±7 years), and 57 technicians (37 males; 40±12 years) working for a median of 10 years (quartiles: 5-24 years). Skin lesions (P=0.002), orthopedic illness (P<0.001), cataract (P=0.003), hypertension (P=0.02), and hypercholesterolemia (P<0.001) were all significantly higher in exposed versus nonexposed group, with a clear gradient unfavorable for physicians over technicians and nurses and for longer history of work (>16 years). In highly exposed physicians, adjusted odds ratio ranged from 1.7 for hypertension (95% confidence interval: 1-3; P=0.05), 2.9 for hypercholesterolemia (95% confidence interval: 1-5; P=0.004), 4.5 for cancer (95% confidence interval: 0.9-25; P=0.06), to 9 for cataract (95% confidence interval: 2-41; P=0.004). Health problems are more frequently observed in workers performing fluoroscopically guided cardiovascular procedures than in unexposed controls, raising the need to spread the culture of safety in the cath laboratory. © 2016 American Heart Association, Inc.
Mendiratta-Lala, Mishal; Williams, Todd R; Mendiratta, Vivek; Ahmed, Hafeez; Bonnett, John W
2015-04-01
The purpose of this study was to evaluate the effectiveness of a multifaceted simulation-based resident training for CT-guided fluoroscopic procedures by measuring procedural and technical skills, radiation dose, and procedure times before and after simulation training. A prospective analysis included 40 radiology residents and eight staff radiologists. Residents took an online pretest to assess baseline procedural knowledge. Second-through fourth-year residents' baseline technical skills with a procedural phantom were evaluated. First-through third-year residents then underwent formal didactic and simulation-based procedural and technical training with one of two interventional radiologists and followed the training with 1 month of supervised phantom-based practice. Thereafter, residents underwent final written and practical examinations. The practical examination included essential items from a 20-point checklist, including site and side marking, consent, time-out, and sterile technique along with a technical skills portion assessing pedal steps, radiation dose, needle redirects, and procedure time. The results indicated statistically significant improvement in procedural and technical skills after simulation training. For residents, the median number of pedal steps decreased by three (p=0.001), median dose decreased by 15.4 mGy (p<0.001), median procedure time decreased by 4.0 minutes (p<0.001), median number of needle redirects decreased by 1.0 (p=0.005), and median number of 20-point checklist items successfully completed increased by three (p<0.001). The results suggest that procedural skills can be acquired and improved by simulation-based training of residents, regardless of experience. CT simulation training decreases procedural time, decreases radiation dose, and improves resident efficiency and confidence, which may transfer to clinical practice with improved patient care and safety.
NASA Astrophysics Data System (ADS)
Russ, M.; Shankar, A.; Setlur Nagesh, S. V.; Ionita, C. N.; Bednarek, D. R.; Rudin, S.
2017-03-01
X-ray detectors to meet the high-resolution requirements for endovascular image-guided interventions (EIGIs) are being developed and evaluated. A new 49.5-micron pixel prototype detector is being investigated and compared to the current suite of high-resolution fluoroscopic (HRF) detectors. This detector featuring a 300-micron thick CsI(Tl) scintillator, and low electronic noise CMOS readout is designated the HRF- CMOS50. To compare the abilities of this detector with other existing high resolution detectors, a standard performance metric analysis was applied, including the determination of the modulation transfer function (MTF), noise power spectra (NPS), noise equivalent quanta (NEQ), and detective quantum efficiency (DQE) for a range of energies and exposure levels. The advantage of the smaller pixel size and reduced blurring due to the thin phosphor was exemplified when the MTF of the HRF-CMOS50 was compared to the other high resolution detectors, which utilize larger pixels, other optical designs or thicker scintillators. However, the thinner scintillator has the disadvantage of a lower quantum detective efficiency (QDE) for higher diagnostic x-ray energies. The performance of the detector as part of an imaging chain was examined by employing the generalized metrics GMTF, GNEQ, and GDQE, taking standard focal spot size and clinical imaging parameters into consideration. As expected, the disparaging effects of focal spot unsharpness, exacerbated by increasing magnification, degraded the higher-frequency performance of the HRF-CMOS50, while increasing scatter fraction diminished low-frequency performance. Nevertheless, the HRF-CMOS50 brings improved resolution capabilities for EIGIs, but would require increased sensitivity and dynamic range for future clinical application.
Patient doses from fluoroscopically guided cardiac procedures in pediatrics
NASA Astrophysics Data System (ADS)
Martinez, L. C.; Vano, E.; Gutierrez, F.; Rodriguez, C.; Gilarranz, R.; Manzanas, M. J.
2007-08-01
Infants and children are a higher risk population for radiation cancer induction compared to adults. Although some values on pediatric patient doses for cardiac procedures have been reported, data to determine reference levels are scarce, especially when compared to those available for adults in diagnostic and therapeutic procedures. The aim of this study is to make a new contribution to the scarce published data in pediatric cardiac procedures and help in the determination of future dose reference levels. This paper presents a set of patient dose values, in terms of air kerma area product (KAP) and entrance surface air kerma (ESAK), measured in a pediatric cardiac catheterization laboratory equipped with a biplane x-ray system with dynamic flat panel detectors. Cardiologists were properly trained in radiation protection. The study includes 137 patients aged between 10 days and 16 years who underwent diagnostic catheterizations or therapeutic procedures. Demographic data and technical details of the procedures were also gathered. The x-ray system was submitted to a quality control programme, including the calibration of the transmission ionization chamber. The age distribution of the patients was 47 for <1 year; 52 for 1-<5 years; 25 for 5-<10 years and 13 for 10-<16 years. Median values of KAP were 1.9, 2.9, 4.5 and 15.4 Gy cm2 respectively for the four age bands. These KAP values increase by a factor of 8 when moving through the four age bands. The probability of a fatal cancer per fluoroscopically guided cardiac procedure is about 0.07%. Median values of ESAK for the four age bands were 46, 50, 56 and 163 mGy, which lie far below the threshold for deterministic effects on the skin. These dose values are lower than those published in previous papers.
Tiegs-Heiden, C A; Murthy, N S; Geske, J R; Diehn, F E; Schueler, B A; Wald, J T; Kaufmann, T J; Lehman, V T; Carr, C M; Amrami, K K; Morris, J M; Thielen, K R; Maus, T P
2016-01-01
To investigate whether there are differences in fluoroscopy time and patient dose for fluoroscopically guided lumbar transforaminal epidural steroid injections (TFESIs) performed by staff radiologists versus with trainees and to evaluate the effect of patient body mass index (BMI) on fluoroscopy time and patient dose, including their interactions with other variables. Single-level lumbar TFESIs (n=1844) between 1 January 2011 and 31 December 2013 were reviewed. Fluoroscopy time, reference point air kerma (Ka,r), and kerma area product (KAP) were recorded. BMI and trainee involvement were examined as predictors of fluoroscopy time, Ka,r, and KAP in models adjusted for age and gender in multivariable linear models. Stratified models of BMI groups by trainee presence were performed. Increased age was the only significant predictor of increased fluoroscopy time (p<0.0001). Ka,r and KAP were significantly higher in patients with a higher BMI (p<0.0001 and p=0.0009). When stratified by BMI, longer fluoroscopy time predicted increased Ka,r and KAP in all groups (p<0.0001). Trainee involvement was not a statistically significant predictor of fluoroscopy time or Ka,r in any BMI category. KAP was lower with trainees in the overweight group (p=0.0009) and higher in male patients for all BMI categories (p<0.02). Trainee involvement did not result in increased fluoroscopy time or patient dose. BMI did not affect fluoroscopy time; however, overweight and obese patients received significantly higher Ka,r and KAP. Male patients received a higher KAP in all BMI categories. Limiting fluoroscopy time and good collimation practices should be reinforced in these patients. Copyright © 2015 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wunderle, K; Wayne State University School of Medicine, Detroit, MI; Godley, A
Purpose: The purpose of this investigation was to quantify percent depth dose (PDD) curves for fluoroscopic x-ray beam qualities incorporating added copper filtration. Methods: A PTW (Freiburg, Germany) MP3 water tank was used with a Standard Imaging (Middleton, WI) Exradin Model 11 Spokas Chamber to measure PDD curves for 60, 80, 100 and 120 kVp x-ray beams with copper filtration ranging from 0.0–0.9 mm at 22cm and 42cm fields of view from 0 to 150 mm of water. A free-in-air monitor chamber was used to normalize the water tank data to fluctuations in output from the fluoroscope. The measurements weremore » acquired on a Siemens (Erlangen, Germany) Artis ZeeGo fluoroscope. The fluoroscope was inverted from the typical orientation providing an x-ray beam originating from above the water tank. The water tank was positioned so that the water level was located at 60cm from the focal spot; which also represents the focal spot to interventional reference plane distance for that fluoroscope. Results: PDDs for 60, 80, 100, and 120 kVp with 0 mm of copper filtration compared well to previously published data by Fetterly et al. [Med Phys, 28, 205 (2001)] for those beam qualities given differences in fluoroscopes, geometric orientation, type of ionization chamber, and the water tank used for data collection. PDDs for 60, 80, 100, and 120 kVp with copper filtration were obtained and are presented, which have not been previously investigated and published. Conclusion: The equipment and processes used to acquire the reported data were sound and compared well with previously published data for PDDs without copper filtration. PDD data for the fluoroscopic x-ray beams incorporating copper filtration can be used as reference data for estimating organ or soft tissue dose at depth involving similar beam qualities or for comparison with mathematical models.« less
Intrauterine insemination versus fallopian tube sperm perfusion in non-tubal infertility
Shekhawat, G.S.
2012-01-01
Background Controlled ovarian hyperstimulation (COH) combined with intrauterine insemination (IUI), using a volume of 0.5 ml of inseminate is commonly offered to couples with non-tubal sub fertility. Another method is Fallopian tube sperm perfusion (FSP) which is based on a pressure injection of 4 ml of sperm suspension while attempting to seal the cervix to prevent semen reflux. This technique ensures the presence of higher sperm density in the fallopian tubes at the time of ovulation than standard IUI. The aim of this study was to compare the efficiency of standard intrauterine insemination (IUI) and Fallopian tube sperm perfusion (FSP) in the treatment of non-tubal infertility. Methods 200 consecutive patients with infertility in 404 stimulated cycles were included in the study. Those randomized to standard IUI included 100 patients in 184 cycles [158 clomiphene citrate/human menopausal gonadotrophin cycles and 26 Letrozole/FSH cycles exclusively for polycystic ovarian disease patients] (group A). Patients subjected to FSP included 100 patients in 220 cycles (193 clomiphene citrate/human menopausal gonadotrophin cycles and 27 Letrozole/FSH cycles exclusively for polycystic ovarian disease patients] (group B). Swim up semen preparation technique was used in all cases. Insemination was performed in both groups 34–37 h after hCG administration. Standard IUI was performed using 0.5 ml of inseminate. In FSP 4 ml inseminate was used. Results In group A (184 IUI cycles in 100 patients), 22 clinical pregnancies (presence of gestational sac with fetal cardiac activity) occurred (11.95% per cycle over four cycles). In group B, (220 cycles of FSP in 100 patients), 48 clinical pregnancies occurred (21.81% per cycle over four cycles) and this difference was statistically significant (p < 0.05). Conclusions For non-tubal sub fertility, the results indicate clear benefit for FSP (Fallopian tube sperm perfusion) over IUI (Intrauterine insemination). PMID:24532873
Enterobius vermicularis Salpingitis Seen in the Setting of Ectopic Pregnancy in a Malaysian Patient
Ravindran, Sarala; Ong, Diana Bee Lan; Chow, Tak Kuan; Low, Kah Pin; Nureena, Zaidi Syeda; Rajoo, Yamuna; Chin, Yuee Teng; Amir, Amirah; Ahmad, Arine Fadzlun; Lim, Yvonne Ai Lian
2014-01-01
We report a rare and unusual case of invasive Enterobius vermicularis infection in a fallopian tube. The patient was a 23-year-old Malaysian woman who presented with suprapubic pain and vaginal bleeding. A clinical diagnosis of ruptured right ovarian ectopic pregnancy was made. She underwent a laparotomy with a right salpingo-oophorectomy. Histopathological examination of the right fallopian tube showed eggs and adult remnants of E. vermicularis, and the results were confirmed using PCR and DNA sequencing. PMID:24989613
Pregnancy after hydrosalpinx treatment with Essure
Inocêncio, Gonçalo; Coutinho, Lúcia; Maciel, Raquel; Barreiro, Márcia
2013-01-01
We present a case of a 29-year-old woman, with a history of ectopic pregnancy, which required left salpingectomy, and with a tortuous and impermeable right fallopian tube, compatible with hydrosalpinx. As hydrosalpinx itself can compromise a future pregnancy, treatment with Essure was proposed before passing to medically assisted procreation techniques. Five months after placement of Essure in the right fallopian tube, an in vitro fertilisation cycle was successfully completed and the woman had a singleton pregnancy and vaginal delivery without intercurrences. PMID:23536627
Percutaneous foot joint needle placement using a C-arm flat-panel detector CT.
Wiewiorski, Martin; Takes, Martin Thanh Long; Valderrabano, Victor; Jacob, Augustinus Ludwig
2012-03-01
Image guidance is valuable for diagnostic injections in foot orthopaedics. Flat-detector computed tomography (FD-CT) was implemented using a C-arm, and the system was tested for needle guidance in foot joint injections. FD-CT-guided joint infiltration was performed in 6 patients referred from the orthopaedic department for diagnostic foot injections. All interventions were performed utilising a flat-panel fluoroscopy system utilising specialised image guidance and planning software. Successful infiltration was defined by localisation of contrast media depot in the targeted joint. The pre- and post-interventional numeric analogue scale (NAS) pain score was assessed. All injections were technically successful. Contrast media deposit was documented in all targeted joints. Significant relief of symptoms was noted by all 6 participants. FD-CT-guided joint infiltration is a feasible method for diagnostic infiltration of midfoot and hindfoot joints. The FD-CT approach may become an alternative to commonly used 2D-fluoroscopically guidance.
NASA Astrophysics Data System (ADS)
Tate, Tyler; Keenan, Molly; Swan, Elizabeth; Black, John; Utzinger, Urs; Barton, Jennifer
2014-12-01
The five year survival rate for ovarian cancer is over 90% if early detection occurs, yet no effective early screening method exists. We have designed and are constructing a dual modality Optical Coherence Tomography (OCT) and Multispectral Fluorescence Imaging (MFI) endoscope to optically screen the Fallopian tube and ovary for early stage cancer. The endoscope reaches the ovary via the natural pathway of the vagina, cervix, uterus and Fallopian tube. In order to navigate the Fallopian tube the endoscope must have an outer diameter of 600 μm, be highly flexible, steerable, tracking and nonperforating. The imaging systems consists of six optical subsystems, two from OCT and four from MFI. The optical subsystems have independent and interrelated design criteria. The endoscope will be tested on realistic tissue models and ex vivo tissue to prove feasibility of future human trials. Ultimately the project aims to provide women the first effective ovarian cancer screening technique.
Lee, Nam Kyung; Choi, Kyung Un; Han, Ga Jin; Kwon, Byung Su; Song, Yong Jung; Suh, Dong Soo; Kim, Ki Hyung
2016-11-14
Pseudocarcinomatous hyperplasia of the fallopian tube is a rare, benign disease characterized by florid epithelial hyperplasia. The authors present the history and details of a 22-year-old woman with bilateral pelvic masses and a highly elevated serum CA-125 level (1,056 U/ml). Ultrasonography and magnetic resonance imaging (MRI) of the pelvis showed bilateral adnexal complex cystic masses with a fusiform or sausage-like shape. Contrast-enhanced fat-suppressed T1-weighted images showed enhancement of papillary projections of the right adnexal mass and enhancement of an irregular thick wall on the left adnexal mass, suggestive of tubal cancer. Based on MRI and laboratory findings, laparotomy was performed under a putative preoperative diagnosis of tubal cancer. The final pathologic diagnosis was pseudocarcinomatous hyperplasia of tubal epithelium associated with acute and chronic salpingitis in both tubes. The authors report a rare case of pseudocarcinomatous hyperplasia of the fallopian tubes mimicking tubal cancer.
Mehrad, Mitra; Ning, Gang; Chen, Eleanor Y; Mehra, Karishma K; Crum, Christopher Paul
2010-09-01
The fallopian tube has recently emerged as an important site of origin for not only early serous cancer in women with inherited mutations in BRCA1/BRCA2 but as a source of many pelvic serous carcinomas. With this increased attention has come the inevitable need to sort out what epithelial abnormalities are clinically important and how they should be reported by the practicing pathologist. This review addresses 4 categories of tubal epithelial change: (1) metaplasias; (2) nonmalignant atypias; (3) potential precursors, including secretory cell outgrowths and p53 signatures; and (4) tubal intraepithelial carcinomas. A modified protocol for sectioning the fallopian tube (SEE-FIM) is discussed and each of the above topics is covered in the context of its differential diagnosis and recommendations for reporting are included. Finally, the rationale for close inspection of the tube, both in presumed benign and malignant disease, is discussed, with reference to an ongoing multi-institutional web-based project (Pelvic-ovarian Cancer Interception project).
Fallopian tubes--literature review of anatomy and etiology in female infertility.
Briceag, I; Costache, A; Purcarea, V L; Cergan, R; Dumitru, M; Briceag, I; Sajin, M; Ispas, A T
2015-01-01
Around 30% of the infertile women worldwide have associated Fallopian tubes pathology. Unfortunately, for a long time, this aspect of infertility has been neglected due to the possibility of bypassing this deadlock through IVF. Up to date free full text literature was reviewed, meaning 4 major textbooks and around 100 articles centered on tubal infertility, in order to raise the awareness on this subject. The anatomy of the Fallopian tube is complex starting from its embryological development and continuing with its vascular supply and ciliated microstructure, that is the key to the process of egg transport to the site of fertilization. There are many strongly documented causes of tubal infertility: infections (Chlamydia Trachomatis, Gonorrhea, and genital tuberculosis), intrauterine contraceptive devices, endometriosis, and complications after abdominal surgery, etc. Although there are still many controversies about the etiology of tubal sterility with the advent of molecular diagnosis of infections there has been cleared the pathway of infection through endometriosis or through ciliary immobility towards the tubal obstruction.
Kwon, Won Kyoung; Kim, Ah Na; Lee, Pil Moo; Park, Cheol Hwan; Kim, Jae Hun
2016-01-01
Background. Caudal epidural steroid injections (CESIs) are an effective treatment for pain. If the injection spreads in a specific pattern depending on the needle position or bevel direction, it would be possible to inject the agent into a specific and desired area. Objectives. We conducted a prospective randomized trial to determine if the needle position and bevel direction have any effect on the epidural spreading pattern in CESI. Methods. Demographic data of the patient were collected. During CESI, the needle position (middle or lateral) and direction (ventral or dorsal) were randomly allocated. Following fluoroscope-guided injection of 4 mL contrast media and 10 mL of injectates, the epidural spreading patterns (ventral or dorsal, bilateral or lateral) were imaged. Results. In the 210 CESIs performed, the needle tip position and bevel direction did not influence the epidural spreading patterns at L4-5 and L5-S1 disc levels. A history of Lumbar spine surgery was associated with a significantly limited spread to each disc level. A midline needle tip position was more effective than the lateral position in spreading to the distant disc levels. Conclusions. Neither the needle tip position nor the bevel direction affected the epidural drug spreading pattern during CESI. PMID:27445609
Heran, Manraj K S; Baird, Robert; Blair, Geoffrey K; Skarsgard, Erik D
2008-05-01
Nonsurgical treatment of recalcitrant pediatric esophageal strictures is challenging. The chemotherapy drug mitomycin-C, which reduces collagen synthesis and scar formation, shows anecdotal promise in the topical treatment of these strictures. Mitomycin-C is cytotoxic, and a safe endoluminal delivery system that avoids inadvertent application to adjacent mucosa has not yet been described. We have treated 2 patients with a combined endoscopic/fluoroscopic technique that ensures protected delivery of a mitomycin-soaked pledget directly to the targeted site. Following pneumatic balloon dilation of the stricture under fluoroscopy, flexible esophagoscopy is performed to the disrupted stricture. Through the gastrostomy tract, a 12F to 16F semirigid sheath is introduced over a guide wire and passed retrograde up the esophagus to the stricture. A grasping forceps introduced through the instrument channel of the esophagoscope is advanced through the sheath and grasps a mitomycin-C-soaked pledget. The pledget is drawn back through the sheath up to the stricture where timed, serial radial applications to the stricture are performed without any contamination of the rest of the esophagus or stomach. We describe a novel technique of endoluminal delivery and focused application of mitomycin-C to an esophageal stricture that avoids inadvertent topical application to adjacent mucosa.
[Arthroscopy-guided fracture management. Ankle joint and calcaneus].
Schoepp, C; Rixen, D
2013-04-01
Arthroscopic fracture management of the ankle and calcaneus requires a differentiated approach. The aim is to minimize surgical soft tissue damage and to visualize anatomical fracture reduction arthroscopically. Moreover, additional cartilage damage can be detected and treated. The arthroscopic approach is limited by deep impressions of the joint surface needing cancellous bone grafting, by multiple fracture lines on the articular side and by high-grade soft tissue damage. An alternative to the minimally invasive arthroscopic approach is open arthroscopic reduction in conventional osteosynthesis. This facilitates correct assessment of surgical reduction of complex calcaneal fractures, otherwise remaining non-anatomical reduction might not be fluoroscopically detected during surgery.
NASA Astrophysics Data System (ADS)
Tate, Tyler; Baggett, Brenda; Rice, Photini; Watson, Jennifer; Orsinger, Gabe; Nymeyer, Ariel C.; Welge, Weston A.; Keenan, Molly; Saboda, Kathylynn; Roe, Denise J.; Hatch, Kenneth; Chambers, Setsuko; Black, John; Utzinger, Urs; Barton, Jennifer
2015-03-01
With early detection, five year survival rates for ovarian cancer are over 90%, yet no effective early screening method exists. Emerging consensus suggests that perhaps over 50% of the most lethal form of the disease, high grade serous ovarian cancer, originates in the Fallopian tube. Cancer changes molecular concentrations of various endogenous fluorophores. Using specific excitation wavelengths and emissions bands on a Multispectral Fluorescence Imaging (MFI) system, spatial and spectral data over a wide field of view can be collected from endogenous fluorophores. Wavelength specific reflectance images provide additional information to normalize for tissue geometry and blood absorption. Ratiometric combination of the images may create high contrast between neighboring normal and abnormal tissue. Twenty-six women undergoing oophorectomy or debulking surgery consented the use of surgical discard tissue samples for MFI imaging. Forty-nine pieces of ovarian tissue and thirty-two pieces of Fallopian tube tissue were collected and imaged with excitation wavelengths between 280 nm and 550 nm. After imaging, each tissue sample was fixed, sectioned and HE stained for pathological evaluation. Comparison of mean intensity values between normal, benign, and cancerous tissue demonstrate a general trend of increased fluorescence of benign tissue and decreased fluorescence of cancerous tissue when compared to normal tissue. The predictive capabilities of the mean intensity measurements are tested using multinomial logistic regression and quadratic discriminant analysis. Adaption of the system for in vivo Fallopian tube and ovary endoscopic imaging is possible and is briefly described.
Fiber optic laser light scattering measurement of ciliary function of the fallopian tube
NASA Astrophysics Data System (ADS)
Halbert, Sheridan A.; Lim, Kap; Lee, Wylie I.
1990-07-01
A fiber-optic laser light-scattering system (FLS) for measuring ciliary function was evaluated by means of three sets of in vitro experiments. First, FLS performance was compared to that of a previously proven benchtop laser system (BLS). Using tissue excised from rabbit fallopian tubes, ciliary beat frequency (CBF) of each sample was measured with FLS and BLS. Paired CBF measurements showed excellent correlation between the two systems (r =0.93). Second, the FLS was used to evaluate the dependency of CBF on temperature (T) by using tissue sampies of rabbit oviductal fimbna. Regression analysis of CBF vs T showed a linear relationship over the range of 18-37°C for both individual samples (r =0.98) and pooled data from all experiments (r = 0.84). Fmally, the relalionship between CBF and ciliary ovum transport rate (TR) was tested by using T to modulate CBF of rabbit fimbria, in vitro. The relationship was linear over the range of CBF from 10 to 30 Hz (r2 = 0.83). At 37°C, CBF = 31+/-1 Hz, and TR = O.12+/-.02 mm/sec. equal to ovum transport rate in situ. The FLS is a valuable tool for characterizing ciliary activity and thus ovum transport function. Owing to the fact that ciliary dyskinesia resulting from disease of the fallopian tube is associated with infeitility, the FLS may be useful to acquire data important to the clinical evaluation of fallopian tube function and female infertility.
Immunohistochemical localization of HE4 in benign, borderline, and malignant lesions of the ovary.
Georgakopoulos, Penelope; Mehmood, Saira; Akalin, Ali; Shroyer, Kenneth R
2012-11-01
Despite advances in the development of novel methods to improve treatment, ovarian carcinoma is still the leading cause of gynecologic cancer death in the United States and other industrialized nations. Improvements in the clinical outcome of ovarian cancer will be achieved if methods can be developed to enable the detection of these tumors at the earliest possible stage. Thus, it is critically important to identify and validate new biomarkers of ovarian cancer. HE4 expression was defined by immunohistochemical analysis of a wide range of benign, borderline, and malignant ovarian lesions, including serous, endometrioid, mucinous, and clear cell lesions of the ovary and in primary tubal carcinomas and the normal fallopian tube. At the cellular level, HE4 was highly expressed in malignant ovarian tumors and in a wide range of benign and borderline ovarian lesions. In addition, HE4 was highly expressed in primary fallopian tube carcinomas and benign fallopian tubal epithelial cells. These results support the conclusion that HE4 is widely expressed in most benign, borderline, and malignant lesions of the ovary and the fallopian tube. The detection of HE4 expression at high levels in some benign lesions and normal tissues suggests that HE4 could have limited specificity as a marker of ovarian or tubal carcinoma. Furthermore, the relatively weak expression that was observed in many ovarian carcinomas indicates that HE4 could fail to detect some cases of primary or recurrent disease.
Minimally invasive radiologically guided intervention for the treatment of salivary calculi.
Brown, Jackie E; Drage, Nicholas A; Escudier, Michael P; Wilson, Ron F; McGurk, Mark
2002-01-01
To describe the technique and examine the value of salivary stone extraction using a minimally invasive, radiologically guided approach as an alternative to salivary gland surgery for the treatment of benign salivary gland obstruction. Eighty-six cases of sialolithiasis (83 patients) were treated by stone removal using a Dormia basket under local anesthesia and fluoroscopic guidance. Postoperative assessment was made clinically at review, by sialogram and by questionnaire. Of 86 cases of sialolithiasis treated, in 55 (64%) it was possible to remove all stones. In 12 cases (14%) part of a stone or some of a number of calculi were removed and in 19 cases (22%) the procedure failed. The commonest reason for failure was fixation of the stone within the duct. Symptoms at review (range 1-49 months, mean 17 months) were relieved in 55 of 67 (82%) of cases where a stone or portion of stone was removed. Stone removal from the salivary duct system by radiologically guided, minimally invasive approach is a simple procedure with low morbidity and high patient acceptance when appropriate selection criteria are applied. These criteria are considered and recommendations made.
Hashimoto, Sho; Takahashi, Akihiko; Yamada, Takeshi; Mizuguchi, Yukio; Taniguchi, Norimasa; Hata, Tetsuya; Nakajima, Shunsuke
2017-11-20
The extension support guiding catheter has been used to perform complex percutaneous coronary intervention to increase back-up support for the guiding catheter or to ensure deep intubation for device delivery. However, because of its monorail design, advancement of the stent into the distal extension tubing segment is sometimes problematic. Although this problem is considered due to simple collision of the stent, operators have observed tangling between a monorail extension catheter and coronary guidewire in some patients. To examine movement of the collar of the extension guide catheter during advancement of the guiding catheter, we set up an in vitro model in which the guiding catheter had two curves. Rotation of the extension guide catheter was examined by both fluoroscopic imaging and movement of the hub of the proximal end of the catheter. During advancement in the first curve, the collar moved toward the outer side of the curve of the guiding catheter as the operator pushed the shaft of the extension guiding catheter, which overrode the guidewire. After crossing the first curve, the collar moved again to the outer side of the second curve (the inner side of the first curve) of the mother catheter, and then, another clockwise rotation was observed in the proximal hub. Consequently, the collar and tubing portion of the extension guide catheter rotated 360° around the coronary guidewire, and the monorail extension catheter and guidewire became tangled. There is a potential risk of unintentional twisting with the guidewire during advancement into the curved guiding catheter because of its monorail design.
Enterobius vermicularis salpingitis seen in the setting of ectopic pregnancy in a Malaysian patient.
Ngui, Romano; Ravindran, Sarala; Ong, Diana Bee Lan; Chow, Tak Kuan; Low, Kah Pin; Nureena, Zaidi Syeda; Rajoo, Yamuna; Chin, Yuee Teng; Amir, Amirah; Ahmad, Arine Fadzlun; Lim, Yvonne Ai Lian; Mahmud, Rohela
2014-09-01
We report a rare and unusual case of invasive Enterobius vermicularis infection in a fallopian tube. The patient was a 23-year-old Malaysian woman who presented with suprapubic pain and vaginal bleeding. A clinical diagnosis of ruptured right ovarian ectopic pregnancy was made. She underwent a laparotomy with a right salpingo-oophorectomy. Histopathological examination of the right fallopian tube showed eggs and adult remnants of E. vermicularis, and the results were confirmed using PCR and DNA sequencing. Copyright © 2014, American Society for Microbiology. All Rights Reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Slattery, Michael M.; Goh, Gerard S.; Power, Sarah
PurposeTo prospectively compare the procedural time and complication rates of ultrasound-guided and fluoroscopy-assisted antegrade common femoral artery (CFA) puncture techniques.Materials and MethodsHundred consecutive patients, undergoing a vascular procedure for which an antegrade approach was deemed necessary/desirable, were randomly assigned to undergo either ultrasound-guided or fluoroscopy-assisted CFA puncture. Time taken from administration of local anaesthetic to vascular sheath insertion in the superficial femoral artery (SFA), patients’ age, body mass index (BMI), fluoroscopy radiation dose, haemostasis method and immediate complications were recorded. Mean and median values were calculated and statistically analysed with unpaired t tests.ResultsSixty-nine male and 31 female patients underwent antegrademore » puncture (mean age 66.7 years). The mean BMI was 25.7 for the ultrasound-guided (n = 53) and 25.3 for the fluoroscopy-assisted (n = 47) groups. The mean time taken for the ultrasound-guided puncture was 7 min 46 s and for the fluoroscopy-assisted technique was 9 min 41 s (p = 0.021). Mean fluoroscopy dose area product in the fluoroscopy group was 199 cGy cm{sup 2}. Complications included two groin haematomas in the ultrasound-guided group and two retroperitoneal haematomas and one direct SFA puncture in the fluoroscopy-assisted group.ConclusionUltrasound-guided technique is faster and safer for antegrade CFA puncture when compared to the fluoroscopic-assisted technique alone.« less
Preclinical Feasibility of a Technology Framework for MRI-guided Iliac Angioplasty
Rube, Martin A.; Fernandez-Gutierrez, Fabiola; Cox, Benjamin F.; Holbrook, Andrew B.; Houston, J. Graeme; White, Richard D.; McLeod, Helen; Fatahi, Mahsa; Melzer, Andreas
2015-01-01
Purpose Interventional MRI has significant potential for image guidance of iliac angioplasty and related vascular procedures. A technology framework with in-room image display, control, communication and MRI-guided intervention techniques was designed and tested for its potential to provide safe, fast and efficient MRI-guided angioplasty of the iliac arteries. Methods A 1.5T MRI scanner was adapted for interactive imaging during endovascular procedures using new or modified interventional devices such as guidewires and catheters. A perfused vascular phantom was used for testing. Pre-, intra- and post-procedural visualization and measurement of vascular morphology and flow was implemented. A detailed analysis of X-Ray fluoroscopic angiography workflow was conducted and applied. Two interventional radiologists and one physician in training performed 39 procedures. All procedures were timed and analyzed. Results MRI-guided iliac angioplasty procedures were successfully performed with progressive adaptation of techniques and workflow. The workflow, setup and protocol enabled a reduction in table time for a dedicated MRI-guided procedure to 6 min 33 s with a mean procedure time of 9 min 2 s, comparable to the mean procedure time of 8 min 42 s for the standard X-Ray guided procedure. Conclusions MRI-guided iliac vascular interventions were found to be feasible and practical using this framework and optimized workflow. In particular the real-time flow analysis was found to be helpful for pre- and post-interventional assessments. Design optimization of the catheters and in vivo experiments are required before clinical evaluation. PMID:25102933
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nose, Takayuki, E-mail: nose-takayuki@nms.ac.jp; Chatani, Masashi; Otani, Yuki
Purpose: High-dose-rate (HDR) brachytherapy misdeliveries can occur at any institution, and they can cause disastrous results. Even a patient's death has been reported. Misdeliveries could be avoided with real-time verification methods. In 1996, we developed a modified C-arm fluoroscopic verification of an HDR Iridium 192 source position prevent these misdeliveries. This method provided excellent image quality sufficient to detect errors, and it has been in clinical use at our institutions for 20 years. The purpose of the current study is to introduce the mechanisms and validity of our straightforward C-arm fluoroscopic verification method. Methods and Materials: Conventional X-ray fluoroscopic images aremore » degraded by spurious signals and quantum noise from Iridium 192 photons, which make source verification impractical. To improve image quality, we quadrupled the C-arm fluoroscopic X-ray dose per pulse. The pulse rate was reduced by a factor of 4 to keep the average exposure compliant with Japanese medical regulations. The images were then displayed with quarter-frame rates. Results: Sufficient quality was obtained to enable observation of the source position relative to both the applicators and the anatomy. With this method, 2 errors were detected among 2031 treatment sessions for 370 patients within a 6-year period. Conclusions: With the use of a modified C-arm fluoroscopic verification method, treatment errors that were otherwise overlooked were detected in real time. This method should be given consideration for widespread use.« less
Nose, Takayuki; Chatani, Masashi; Otani, Yuki; Teshima, Teruki; Kumita, Shinichirou
2017-03-15
High-dose-rate (HDR) brachytherapy misdeliveries can occur at any institution, and they can cause disastrous results. Even a patient's death has been reported. Misdeliveries could be avoided with real-time verification methods. In 1996, we developed a modified C-arm fluoroscopic verification of an HDR Iridium 192 source position prevent these misdeliveries. This method provided excellent image quality sufficient to detect errors, and it has been in clinical use at our institutions for 20 years. The purpose of the current study is to introduce the mechanisms and validity of our straightforward C-arm fluoroscopic verification method. Conventional X-ray fluoroscopic images are degraded by spurious signals and quantum noise from Iridium 192 photons, which make source verification impractical. To improve image quality, we quadrupled the C-arm fluoroscopic X-ray dose per pulse. The pulse rate was reduced by a factor of 4 to keep the average exposure compliant with Japanese medical regulations. The images were then displayed with quarter-frame rates. Sufficient quality was obtained to enable observation of the source position relative to both the applicators and the anatomy. With this method, 2 errors were detected among 2031 treatment sessions for 370 patients within a 6-year period. With the use of a modified C-arm fluoroscopic verification method, treatment errors that were otherwise overlooked were detected in real time. This method should be given consideration for widespread use. Copyright © 2016 Elsevier Inc. All rights reserved.
Kurman, Robert J.; Vang, Russell; Junge, Jette; Hannibal, Charlotte Gerd; Kjaer, Susanne K.; Shih, Ie-Ming
2011-01-01
In contrast to the controversy regarding the terminology and behavior of ovarian noninvasive low-grade serous tumors (atypical proliferative serous tumor [APST] and serous borderline tumor [SBT]), little attention has been directed to their origin. Similarly, until recently, proliferative lesions in the fallopian tube have not been extensively studied. The recent proposal that ovarian high-grade serous carcinomas are derived from intraepithelial carcinoma in the fallopian tube prompted us to evaluate the possible role of the fallopian tube in the genesis of low-grade serous tumors. We have identified a lesion, designated “papillary tubal hyperplasia (PTH)”, characterized by small rounded clusters of tubal epithelial cells and small papillae, with or without associated psammoma bodies, that are present within the tubal lumen and which are frequently associated with APSTs. Twenty-two cases in this study were selected from a population-based study in Denmark of approximately 1000 patients with low-grade ovarian serous tumors in whom implants were identified on the fallopian tube. Seven additional cases were seen recently in consultation at The Johns Hopkins Hospital (JHH). These 7 cases were not associated with an ovarian tumor. Papillary tubal hyperplasia was found in 20 (91%) of the 22 cases in the Danish study. Based on this association of PTH with APSTs with implants and the close morphologic resemblance of PTH, not only to the primary ovarian APSTs but also to the noninvasive epithelial implants and endosalpingiosis, we speculate that the small papillae and clusters of cells from the fallopian tubes implant on ovarian and peritoneal surfaces to produce these lesions. The 7 JHH cases of PTH that were not associated with an ovarian tumor support the view that PTH is the likely precursor lesion. We propose a model for the development of ovarian and extraovarian low-grade serous proliferations (APST, noninvasive epithelial implants and endosalpingiosis) that postulates that all of these lesions are derived from PTH, which appears to be induced by chronic inflammation. If this hypothesis is confirmed, then it can be concluded that low- and high-grade ovarian tumors develop from tubal epithelium and involve the ovary secondarily. PMID:21997682
Three-photon imaging of ovarian cancer
NASA Astrophysics Data System (ADS)
Barton, Jennifer K.; Amirsolaimani, Babak; Rice, Photini; Hatch, Kenneth; Kieu, Khanh
2016-02-01
Optical imaging methods have the potential to detect ovarian cancer at an early, curable stage. Optical imaging has the disadvantage that high resolution techniques require access to the tissue of interest, but miniature endoscopes that traverse the natural orifice of the reproductive tract, or access the ovaries and fallopian tubes through a small incision in the vagina wall, can provide a minimally-invasive solution. We have imaged both rodent and human ovaries and fallopian tubes with a variety of endoscope-compatible modalities. The recent development of fiber-coupled femtosecond lasers will enable endoscopic multiphoton microscopy (MPM). We demonstrated two- and three-photon excited fluorescence (2PEF, 3PEF), and second- and third-harmonic generation microscopy (SHG, THG) in human ovarian and fallopian tube tissue. A study was undertaken to understand the mechanisms of contrast in these images. Six patients (normal, cystadenoma, and ovarian adenocarcinoma) provided ovarian and fallopian tube biopsies. The tissue was imaged with three-dimensional optical coherence tomography, multiphoton microscopy, and frozen for histological sectioning. Tissue sections were stained with hematoxylin and eosin, Masson's trichrome, and Sudan black. Approximately 1 μm resolution images were obtained with an excitation source at 1550 nm. 2PEF signal was absent. SHG signal was mainly from collagen. 3PEF and THG signal came from a variety of sources, including a strong signal from fatty connective tissue and red blood cells. Adenocarcinoma was characterized by loss of SHG signal, whereas cystic abnormalities showed strong SHG. There was limited overlap of two- and three- photon signals, suggesting that three-photon imaging can provide additional information for early diagnosis of ovarian cancer.
Physiology of upward transport in the human female genital tract.
Zervomanolakis, I; Ott, H W; Hadziomerovic, D; Mattle, V; Seeber, B E; Virgolini, I; Heute, D; Kissler, S; Leyendecker, G; Wildt, L
2007-04-01
The uterus and fallopian tubes represent a functionally united peristaltic pump under the endocrine control of ipsilateral ovary. We have examined this function by using hysterosalpingoscintigraphy (HSS), recording of intrauterine pressure, electrohysterography, and Doppler sonography of the fallopian tubes. An uptake of labeled particles into the uterus was observed during the follicular and luteal phases of the cycle after application into the vagina. Transport into the oviducts, however, could only be demonstrated during the follicular phase. Furthermore, the predominant transport was into the tube ipsilateral to the ovary containing the dominant follicle. The pregnancy rate following spontaneous intercourse or insemination was higher in those women in whom ipsilateral transport could be demonstrated. The amount of material transported to the ipsilateral tube was increased after oxytocin administration, as demonstrated by radionuclide imaging and by Doppler sonography following instillation of ultrasound contrast medium. An increase in the basal tone and amplitude of contractions was observed after oxytocin administration. These results support the idea that the uterus and fallopian tubes act as a peristaltic pump, which increases transport of sperm into the oviduct ipsilateral to the ovary bearing the dominant follicle. Oxytocin appears to play a critical role in this peristaltic pump. A failure of the peristaltic mechanism is possibly responsible for infertility. We propose the term tubal transport disorder (TTD) as a nosological entity. Results from HSS could be a useful adjunct for choosing treatment modalities in patients with patent fallopian tubes suffering from infertility. These patients may be better served with in vitro fertilization (IVF).
Kadour-Peero, Einav; Sagi-Dain, Lena; Cohen, Gil; Korobochka, Roman; Agbarya, Abed; Bejar, Jacob; Sagi, Shlomi
2018-05-07
BACKGROUND There is now evidence to support that some cases of high-grade serous papillary carcinoma arise from the fallopian tubes rather than the ovaries. Common symptoms at presentation include abdominal pain and swelling, vomiting, altered bowel habit and urinary symptoms. To our knowledge, this is the first case of serous papillary carcinoma presenting as a vaginal mass lesion. CASE REPORT A 41-year-old woman was referred to the Bnai-Zion Medical Center with the main complaint of irregular vaginal bleeding, vaginal mucous discharge, and suspected pelvic mass. Physical examination showed a soft, painless mass, measuring about 10 cm in diameter located mainly in the recto-vaginal septum, but not involving the uterus. Ultrasound examination showed no abnormal ovarian or uterine findings. Transvaginal biopsies of the mass showed a poorly differentiated serous papillary carcinoma of ovarian, tubal, or peritoneal origin. The physical examination and imaging findings strongly indicated an inoperable tumor, and the patient was treated with neoadjuvant (pre-surgical) chemotherapy. Pre-operative computed tomography (CT) imaging showed the partial involvement of the colon, and so surgical treatment included total abdominal hysterectomy, bilateral salpingo-oophorectomy, omentectomy, partial vaginectomy, anterior rectal resection, and lymph node dissection. Histopathology of the surgical specimens showed a poorly differentiated serous carcinoma originating from the fimbria of the right fallopian tube. CONCLUSIONS To the best of our knowledge, this is the first report to describe primary fallopian tube papillary serous carcinoma presenting as a vaginal mass. Therefore, physicians should be aware of this possible diagnosis.
Sheen, Jae Jon; Jiang, Yuan Yuan; Kim, Young Eun; Maeng, Jun Young; Kim, Tae-Il; Lee, Deok Hee
2018-03-23
Onyx embolization is a treatment for brain arteriovenous malformations (AVMs). However, multistage embolization usually involves the presence of radiodense Onyx cast from the previous sessions, which may influence the fluoroscopic radiation dose. We compared the fluoroscopic dose between the initial and final embolization sessions. From January 2014 to September 2016, 18 patients underwent multistage Onyx embolization (more than twice) for brain AVMs. The total fluoroscopic duration (minutes), dose-area product (DAP, Gy×cm 2 ), and cumulative air kerma (CAK, mGy) of both the frontal and lateral planes were obtained. We compared the frontal and lateral fluoroscopic dose rates (dose/time) of the final embolization session with those of the initial session. The relationship between the injected Onyx volume and radiation dose was tested. The initial and final procedures on the frontal plane showed significantly different fluoroscopic dose rates (DAP: initial 0.668 Gy×cm 2 /min, final 0.848 Gy×cm 2 /min, P=0.02; CAK: initial 12.7 mGy/min, final 23.1 mGy/min, P=0.007). Those on the lateral plane also showed a similar pattern (DAP: initial 0.365 Gy×cm 2 /min, final 0.519 Gy×cm 2 /min, P=0.03; CAK: initial 6.2 mGy/min, final 12.9 mGy/min, P=0.01). The correlation between the cumulative Onyx volume (vials) and radiation dose ratio of both planes showed an increasing trend (rho 0.4325-0.7053; P=0.0011-0.0730). Owing to the automatic exposure control function during fluoroscopy, successive Onyx embolization procedures increase the fluoroscopic radiation dose in multistage brain AVM embolization because of the presence of radiodense Onyx mass. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
NASA Astrophysics Data System (ADS)
Li, Ruijiang; Lewis, John H.; Cerviño, Laura I.; Jiang, Steve B.
2009-10-01
A major difficulty in conformal lung cancer radiotherapy is respiratory organ motion, which may cause clinically significant targeting errors. Respiratory-gated radiotherapy allows for more precise delivery of prescribed radiation dose to the tumor, while minimizing normal tissue complications. Gating based on external surrogates is limited by its lack of accuracy, while gating based on implanted fiducial markers is limited primarily by the risk of pneumothorax due to marker implantation. Techniques for fluoroscopic gating without implanted fiducial markers (markerless gating) have been developed. These techniques usually require a training fluoroscopic image dataset with marked tumor positions in the images, which limits their clinical implementation. To remove this requirement, this study presents a markerless fluoroscopic gating algorithm based on 4DCT templates. To generate gating signals, we explored the application of three similarity measures or scores between fluoroscopic images and the reference 4DCT template: un-normalized cross-correlation (CC), normalized cross-correlation (NCC) and normalized mutual information (NMI), as well as average intensity (AI) of the region of interest (ROI) in the fluoroscopic images. Performance was evaluated using fluoroscopic and 4DCT data from three lung cancer patients. On average, gating based on CC achieves the highest treatment accuracy given the same efficiency, with a high target coverage (average between 91.9% and 98.6%) for a wide range of nominal duty cycles (20-50%). AI works well for two patients out of three, but failed for the third patient due to interference from the heart. Gating based on NCC and NMI usually failed below 50% nominal duty cycle. Based on this preliminary study with three patients, we found that the proposed CC-based gating algorithm can generate accurate and robust gating signals when using 4DCT reference template. However, this observation is based on results obtained from a very limited dataset, and further investigation on a larger patient population has to be done before its clinical implementation.
3D fluoroscopic image estimation using patient-specific 4DCBCT-based motion models
Dhou, Salam; Hurwitz, Martina; Mishra, Pankaj; Cai, Weixing; Rottmann, Joerg; Li, Ruijiang; Williams, Christopher; Wagar, Matthew; Berbeco, Ross; Ionascu, Dan; Lewis, John H.
2015-01-01
3D fluoroscopic images represent volumetric patient anatomy during treatment with high spatial and temporal resolution. 3D fluoroscopic images estimated using motion models built using 4DCT images, taken days or weeks prior to treatment, do not reliably represent patient anatomy during treatment. In this study we develop and perform initial evaluation of techniques to develop patient-specific motion models from 4D cone-beam CT (4DCBCT) images, taken immediately before treatment, and use these models to estimate 3D fluoroscopic images based on 2D kV projections captured during treatment. We evaluate the accuracy of 3D fluoroscopic images by comparing to ground truth digital and physical phantom images. The performance of 4DCBCT- and 4DCT- based motion models are compared in simulated clinical situations representing tumor baseline shift or initial patient positioning errors. The results of this study demonstrate the ability for 4DCBCT imaging to generate motion models that can account for changes that cannot be accounted for with 4DCT-based motion models. When simulating tumor baseline shift and patient positioning errors of up to 5 mm, the average tumor localization error and the 95th percentile error in six datasets were 1.20 and 2.2 mm, respectively, for 4DCBCT-based motion models. 4DCT-based motion models applied to the same six datasets resulted in average tumor localization error and the 95th percentile error of 4.18 and 5.4 mm, respectively. Analysis of voxel-wise intensity differences was also conducted for all experiments. In summary, this study demonstrates the feasibility of 4DCBCT-based 3D fluoroscopic image generation in digital and physical phantoms, and shows the potential advantage of 4DCBCT-based 3D fluoroscopic image estimation when there are changes in anatomy between the time of 4DCT imaging and the time of treatment delivery. PMID:25905722
Various hysterosalpingography findings of female genital tuberculosis: A case series
Afzali, Nargess; Ahmadi, Firoozeh; Akhbari, Farnaz
2013-01-01
Background: Genital tuberculosis is a chorionic disease and mostly occurs by haematogenous spread from extra genital source like lungs, peritoneum, lymph nodes and bones. Transmission through a sexual intercourse is also possible. Since the majority of patients are in reproductive ages, involvement of fallopian tubes and endometrium cause infertility in patients. Cases: Reviewing 4 cases of female genital tuberculosis, which referred to an infertility treatment center with various symptoms, we encountered various appearances on hysterosalpingography (HSG). Conclusion: The genitourinary tract is the most common site of extra pulmonary TB. The primary focus of genital tuberculosis is fallopian tubes, which are almost always affected bilaterally but not symmetrically. Because of common involvement of fallopian tubes and endometrial cavity, disease causes infertility. Diagnosis is not easy because genital tuberculosis has a wide range of clinical and radiological manifestations with slow growing symptoms. Detailed hysterosalpingography finding may be helpful in better diagnosis of the disease. This case series aims to depict the various hystrosalpingographic appearances and pathology produced by tuberculosis and related literatures are reviewed in order to establish a better diagnostic evaluation of genital tuberculosis. PMID:24639787
Computerized tomography using video recorded fluoroscopic images
NASA Technical Reports Server (NTRS)
Kak, A. C.; Jakowatz, C. V., Jr.; Baily, N. A.; Keller, R. A.
1975-01-01
A computerized tomographic imaging system is examined which employs video-recorded fluoroscopic images as input data. By hooking the video recorder to a digital computer through a suitable interface, such a system permits very rapid construction of tomograms.
Tricuspid Clip: Step-by-Step and Clinical Data.
Tang, Gilbert H L
2018-01-01
Symptomatic severe tricuspid regurgitation (TR), if untreated, carries a dismal prognosis. These patients are at very high risk for surgical repair or replacement and transcatheter options to treat TR are emerging. More than 300 transcatheter tricuspid repairs with the MitraClip system have been performed worldwide with promising results. The TriClip system, with the MitraClip NT delivered via a dedicated tricuspid steerable guide catheter, is currently under investigation. This article describes the step-by-step technique on using the MitraClip system to perform transcatheter tricuspid repair using echocardiographic and fluoroscopic guidance. The latest data on worldwide experience with tricuspid clipping are also discussed. Copyright © 2017 Elsevier Inc. All rights reserved.
Hybrid treatment of common carotid artery occlusion with ring-stripper endarterectomy plus stenting.
Pintér, László; Cagiannos, Catherine; Bakoyiannis, Chris N; Kolvenbach, Ralf
2007-07-01
Symptomatic occlusion of the common carotid artery with preserved circulation in the internal carotid artery is an uncommon occurrence. We describe a hybrid technique whereby a patient was treated with eversion carotid bifurcation endarterectomy, fluoroscopically guided retrograde ring-stripper common carotid endarterectomy, and stenting of residual stenosis in the disobliterated artery. Successful recanalization was achieved without adverse anatomic or neurologic sequelae. The patient remains asymptomatic with a radiographically patent reconstruction at 1 year. This combination of endovascular and open surgery enables the surgeon to address long occlusions of the common carotid arteries with control of the distal and proximal endarterectomy margins and obviates the need for general anesthesia or sternotomy.
Radiology-guided forceps biopsy and airway stenting in severe airway stenosis.
Li, Zong Ming; Wu, Gang; Han, Xin Wei; Ren, Ke Wei; Zhu, Ming
2014-01-01
We aimed to determine the feasibility, safety, and effectiveness of radiology-guided forceps biopsy and airway stenting in patients with severe airway stenosis. This study involved 28 patients with severe airway stenosis who underwent forceps biopsy between October 2006 and September 2011. Chest multislice computed tomography was used to determine the location and extent of stenosis. Sixteen patients had tracheal stenosis, two patients had stenosis of the tracheal carina, six patients had stenosis of the left main bronchus, and four patients had stenosis of the right main bronchus. Forceps biopsy and stenting of the stenosed area were performed under fluoroscopic guidance in digital subtraction angiography and the biopsy specimens were analyzed histopathologically. We contacted the patients via phone call and utilized a standardized questionnaire to determine their medical condition during a postoperative three-month follow-up. The technical success rate of radiology-guided forceps biopsy was 100%. Biopsy specimens were obtained in all patients. Dyspnea was relieved immediately after stent placement. No serious complications, such as tracheal hemorrhage or perforation, mediastinal emphysema, or asphyxia, occurred. Radiology-guided forceps biopsy and airway stenting can be used for the emergency treatment of severe airway stenosis. This method appears to be safe and effective, and it may be an alternative therapeutic option in patients who cannot tolerate fiberoptic bronchoscopy.
Silicon sensors for catheters and guide wires
NASA Astrophysics Data System (ADS)
Goosen, Hans F.
2001-11-01
One area that can make use of the miniature size of present day micro electromechanical systems (MEMS) is that of the medical field of minimally invasive interventions. These procedures, used for both diagnosis and treatment, use catheters that are advanced through the blood vessels deep into the body, without the need for surgery. However, once inside the body, the doctor performing the procedure is completely reliant on the information the catheter(s) can provide in addition to the projection imaging of a fluoroscope. A good range of sensors for catheters is required for a proper diagnosis. To this end, miniature sensors are being developed to be fitted to catheters and guide wires. As the accurate positioning of these instruments is problematic, it is necessary to combine several sensors on the same guide wire or catheter to measure several parameters in the same location. This however, brings many special problems to the design of the sensors, such as small size, low power consumption, bio-compatibility of materials, robust design for patient safety, a limited number of connections, packaging, etc. This paper will go into both the advantages and design problems of micromachined sensors and actuators in catheters and guide wires. As an example, a multi parameter blood sensor, measuring flow velocity, pressure and oxygen saturation, will be discussed.
Yuksel, B; Saygun, O; Hengirmen, S
2006-01-01
Persistent müllerian duct syndrome is a rare form of male pseudohermaphroditism. A case is reported of normal male appearance with bilateral cryptorchidism and a right irreducible inguinal hernia. On exploration, an uterus with two fallopian tubes and a testicle were found in the hernia sac. The uterus, fallopian tubes and left testicle were en bloc removed. Right orchidopexy and hernia repair were performed. In conclusion, if there is an adult bilateral cryptorchidism, surgeons should take into consideration a persistent müllerian duct syndrome.
Giant cell arteritis of fallopian tube.
Azzena, A; Altavilla, G; Salmaso, R; Vasoin, F; Pellizzari, P; Doria, A
1994-01-01
One case of giant cells arteritis involving tubaric arteries in a postmenopausal woman is described. The patient was 59 years old and presented with asthenia, anemia, fever, weight loss, an abdominal palpable mass and elevated erythrocyte sedimentation rate. Exploratory laparotomy revealed a large ovarian cyst of 14 cm in diameter. Extensive giant cell arteritis, Horton's type, of the small-sizes arteries was found unexpectedly in the fallopian tube of the patient who had had a prior ovariectomy. Giant cell arteritis of the female genital tract is a rare finding in elderly women and may occur as an isolated finding or as part of generalised arteritis.
Kamara, Eli; Robinson, Jonathon; Bas, Marcel A; Rodriguez, Jose A; Hepinstall, Matthew S
2017-01-01
Acetabulum positioning affects dislocation rates, component impingement, bearing surface wear rates, and need for revision surgery. Novel techniques purport to improve the accuracy and precision of acetabular component position, but may have a significant learning curve. Our aim was to assess whether adopting robotic or fluoroscopic techniques improve acetabulum positioning compared to manual total hip arthroplasty (THA) during the learning curve. Three types of THAs were compared in this retrospective cohort: (1) the first 100 fluoroscopically guided direct anterior THAs (fluoroscopic anterior [FA]) done by a surgeon learning the anterior approach, (2) the first 100 robotic-assisted posterior THAs done by a surgeon learning robotic-assisted surgery (robotic posterior [RP]), and (3) the last 100 manual posterior (MP) THAs done by each surgeon (200 THAs) before adoption of novel techniques. Component position was measured on plain radiographs. Radiographic measurements were taken by 2 blinded observers. The percentage of hips within the surgeons' "target zone" (inclination, 30°-50°; anteversion, 10°-30°) was calculated, along with the percentage within the "safe zone" of Lewinnek (inclination, 30°-50°; anteversion, 5°-25°) and Callanan (inclination, 30°-45°; anteversion, 5°-25°). Relative risk (RR) and absolute risk reduction (ARR) were calculated. Variances (square of the standard deviations) were used to describe the variability of cup position. Seventy-six percentage of MP THAs were within the surgeons' target zone compared with 84% of FA THAs and 97% of RP THAs. This difference was statistically significant, associated with a RR reduction of 87% (RR, 0.13 [0.04-0.40]; P < .01; ARR, 21%; number needed to treat, 5) for RP compared to MP THAs. Compared to FA THAs, RP THAs were associated with a RR reduction of 81% (RR, 0.19 [0.06-0.62]; P < .01; ARR, 13%; number needed to treat, 8). Variances were lower for acetabulum inclination and anteversion in RP THAs (14.0 and 19.5) as compared to the MP (37.5 and 56.3) and FA (24.5 and 54.6) groups. These differences were statistically significant (P < .01). Adoption of robotic techniques delivers significant and immediate improvement in the precision of acetabular component positioning during the learning curve. While fluoroscopy has been shown to be beneficial with experience, a learning curve exists before precision improves significantly. Copyright © 2016 Elsevier Inc. All rights reserved.
New Jersey's Thomas Edison and the fluoroscope.
Tselos, G D
1995-11-01
Thomas Edison played a major role in the development of early x-ray technology in 1896, notably increasing tube power and reliability and making the fluoroscope a practical instrument. Eventually, Edison would move x-ray technology from the laboratory to the marketplace.
Weksler, Natan; Velan, Gad J; Semionov, Michael; Gurevitch, Boris; Klein, Moti; Rozentsveig, Vsevolod; Rudich, Tzvia
2007-12-01
It is a common practice to the link low back pain with protruding disc even when neurological signs are absent. Because pain caused by sacroiliac joint dysfunction can mimic discogenic or radicular low back pain, we assumed that the diagnosis of sacroiliac joint dysfunction is frequently overlooked. To assess the incidence of sacroiliac joint dysfunction in patients with low back pain and positive disc findings on CT scan or MRI, but without claudication or objective neurological deficits. Fifty patients with low back pain and disc herniation, without claudication or neurological abnormalities such as decreased motor strength, sensory alterations or sphincter incontinence and with positive pain provocation tests for sacroiliac joint dysfunction were submitted to fluoroscopic diagnostic sacroiliac joint infiltration. The mean baseline VAS pain score was 7.8 +/- 1.77 (range 5-10). Thirty minutes after infiltration, the mean VAS score was 1.3 +/- 1.76 (median 0.000E+00 with an average deviation from median = 1.30) (P = 0.0002). Forty-six patients had a VAS score ranging from 0 to 3, 8 weeks after the fluoroscopic guided infiltration. There were no serious complications after treatment. An unanticipated motor block that required hospitalization was seen in four patients, lasting from 12 to 36 h. Sacroiliac joint dysfunction should be considered strongly in the differential diagnosis of low back pain in this group of patients.
Guided percutaneous fine-needle aspiration biopsy of the liver
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ho, C.S.; McLoughlin, M.J.; Tao, L.C.
1981-04-01
Forty patients with suspected malignant disease of the liver underwent percutaneous fine-needle aspiration biopsy with radioisotope scintigraphic and fluoroscopic guidance. The needle was aimed at focal defects identified on the liver scan and several passes were made. When the scan was diffusely abnormal, the liver was widely sampled with multiple passes. Thirty patients were eventually considered to have malignant disease and aspiration biopsy was positive in 28 (93%) of these patients, including 25 of 26 with liver metastases (96%). There were two false-positive results and one minor complication. In 24 patients, conventional wide-bore needle biopsy was also performed. In thismore » group, 16 patients had a final diagnosis of hepatic malignancy. Aspiration biopsies were positive in 14 of these (87%) and conventional needle biopsies were positive in four (25%). Guided percutaneous fine-needle aspiration biopsy is recommended for pathologic diagnosis of hepatic malignancy because of its simplicity, high yield, and reasonable safety.« less
Kar, Tushar; Kar, Asaranti; Dhal, Ipsita; Panda, Sasmita; Biswal, Priyadarshini; Nayak, Bhagyalaxmi; Rout, Niranjan; Samantray, Sagarika
2017-12-01
Pelvic (non-uterine) high-grade serous carcinomas (PHGSC) including ovarian, tubal and primary peritoneal serous carcinomas have increased death: incidence ratio due to presentation at advanced stage, rapid progression, poor prognosis and high morbidity. Ambiguity regarding their pathogenesis and lack of a proper screening method is the cause of their late detection and high fatality rate. This study was undertaken to assess the fallopian tube for the presence of precursor lesions in pelvic serous carcinoma. This was a prospective case-control study carried out in a tertiary care center. Consecutive specimens of 55 cases of pelvic high-grade serous carcinoma and 41 controls inclusive of 21 low-grade serous carcinoma, 10 benign adnexal masses and 10 normal adnexa were included in the study. Both side fallopian tubes in each case were subjected to histopathological examination and p53, Ki67 immunohistochemistry. There were 55 cases of PHGSC comprising of 50 cases of ovarian HGSC, two cases of primary peritoneal carcinoma (PPC) and three cases of tubal carcinoma. Serous tubal intraepithelial carcinoma (STIC) was detected in 14 cases (28%), p53 signature in 13 cases (26%) and tubal intraepithelial lesion in transition in 10 cases (20%) of ovarian HGSC. One case (50%) of PPC and one (33%) case of tubal carcinoma revealed the presence of STIC. None of the controls exhibited any precursor lesion except ovarian low-grade serous carcinoma where p53 was detected in 20% of cases. This revelation concludes that fallopian tubes are the sites of precursors of PHGSC to a large extent. In the absence of a proper screening method of HGSC, prophylactic bilateral salpingectomy at hysterectomy for benign diseases can achieve ultimate goal of reduction in incidence of PHGSC.
Mutant p53 expression in fallopian tube epithelium drives cell migration.
Quartuccio, Suzanne M; Karthikeyan, Subbulakshmi; Eddie, Sharon L; Lantvit, Daniel D; Ó hAinmhire, Eoghainín; Modi, Dimple A; Wei, Jian-Jun; Burdette, Joanna E
2015-10-01
Ovarian cancer is the fifth leading cause of cancer death among US women. Evidence supports the hypothesis that high-grade serous ovarian cancers (HGSC) may originate in the distal end of the fallopian tube. Although a heterogeneous disease, 96% of HGSC contain mutations in p53. In addition, the "p53 signature," or overexpression of p53 protein (usually associated with mutation), is a potential precursor lesion of fallopian tube derived HGSC suggesting an essential role for p53 mutation in early serous tumorigenesis. To further clarify p53-mutation dependent effects on cells, murine oviductal epithelial cells (MOE) were stably transfected with a construct encoding for the R273H DNA binding domain mutation in p53, the most common mutation in HGSC. Mutation in p53 was not sufficient to transform MOE cells but did significantly increase cell migration. A similar p53 mutation in murine ovarian surface epithelium (MOSE), another potential progenitor cell for serous cancer, was not sufficient to transform the cells nor change migration suggesting tissue specific effects of p53 mutation. Microarray data confirmed expression changes of pro-migratory genes in p53(R273H) MOE compared to parental cells, which could be reversed by suppressing Slug expression. Combining p53(R273H) with KRAS(G12V) activation caused transformation of MOE into high-grade sarcomatoid carcinoma when xenografted into nude mice. Elucidating the specific role of p53(R273H) in the fallopian tube will improve understanding of changes at the earliest stage of transformation. This information can help develop chemopreventative strategies to prevent the accumulation of additional mutations and reverse progression of the "p53 signature" thereby, improving survival rates. © 2015 UICC.
Krill, Lauren S; Ueda, Stefanie M; Gerardi, Melissa; Bristow, Robert E
2011-02-01
To evaluate the risk of postoperative complications related to HA-CMC use in patients undergoing optimal cytoreductive surgery for primary and recurrent ovarian, fallopian tube, and peritoneal cancers. A single institution retrospective review identified all patients undergoing optimal (≤1 cm) cytoreductive surgery for primary or recurrent ovarian, fallopian tube, and peritoneal cancers between 1/95 and 12/08. Operative details and post-operative complications (<30 days) were extracted from the medical record. Fisher's exact test, Mann-Whitney-U, and multiple regression analyses were performed to identify factors, including HA-CMC use, associated with post-operative complications. Three hundred seventy-five cases were analyzed: HA-CMC was utilized in 168 debulking procedures. There was no difference in the incidence of overall morbidity for patients with HA-CMC compared to those without HA-CMC (OR 1.07; 95% CI: 0.68-1.67). On univariate analysis, application of HA-CMC increased the risk of pelvic abscess (OR 2.66; 95% CI: 1.21-5.86), particularly in the primary surgery setting (OR 4.65; 95% CI: 1.67-12.98) and in patients undergoing hysterectomy (OR 3.36; 95% CI: 1.18-9.53). After controlling for confounding factors using multiple linear regression, HA-CMC use approached statistical significance in predicting an increased risk of pelvic abscess but not major postoperative morbidity. HA-CMC adhesion barrier placement at the time of optimal cytoreductive surgery for ovarian, fallopian tube, and peritoneal cancer is not associated with major postoperative complications but may be associated with increased risk of pelvic abscess. Copyright © 2010 Elsevier Inc. All rights reserved.
21 CFR 1020.32 - Fluoroscopic equipment.
Code of Federal Regulations, 2010 CFR
2010-04-01
.... Radiation therapy simulation systems shall be exempt from this requirement provided the systems are intended... 10, 2006, other than radiation therapy simulation systems, the following applies: (A) Neither the... fluoroscopic equipment manufactured on or after June 10, 2006, other than radiation therapy simulation systems...
Nacey, Nicholas C; Patrie, James T; Fox, Michael G
2016-11-01
The purpose of this study was to determine whether intraarticular sacroiliac joint injections provide greater immediate and short-term pain relief than periarticular sacroiliac joint injections do. The records of all fluoroscopically guided sacroiliac joint injections performed over a 4-year period were identified. Patients who received an injection of 0.5 mL of bupivacaine and 0.5 mL (20 mg) of triamcinolone and who had preinjection, immediate, and 1-week postinjection pain scores (0-10 numeric scale) were included. Images from the procedures were retrospectively reviewed by two musculoskeletal radiologists to determine intraarticular or periarticular administration of the injection with discrepancies resolved by consensus. One hundred thirteen injections in 99 patients (65 women, 34 men; mean age, 59.4 years) met the inclusion criteria. There were 55 intraarticular and 58 periarticular injections. The mean preinjection, immediate, and 1-week postinjection pain scores for the intraarticular injections were 6.0, 1.6, and 4.1 and for the periarticular injections were 6.1, 2.0, and 4.2. The mean immediate and 1-week postinjection pain reduction were statistically significant in both groups (p < 0.001). After adjustment for age, sex, preinjection pain score, time of year, and indication for injection, no significant difference in the preinjection to immediately postinjection change in pain between intraarticular and periarticular injections (mean change, 0.37; p = 0.319) or in the preinjection to 1-week postinjection change in pain (mean change, 0.06; p = 0.888) was noted. The mean fluoroscopy times were 42.4 seconds for intraarticular injections and 60.5 seconds for periarticular injections (p = 0.32). Although both intraarticular and periarticular sacroiliac joint injections provide statistically significant immediate and 1-week postinjection pain relief, no significant difference in the degree of pain relief achieved with intraarticular and periarticular injections was noted.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xiong, Z; Vijayan, S; Rana, V
2015-06-15
Purpose: A system was developed that automatically calculates the organ and effective dose for individual fluoroscopically-guided procedures using a log of the clinical exposure parameters. Methods: We have previously developed a dose tracking system (DTS) to provide a real-time color-coded 3D- mapping of skin dose. This software produces a log file of all geometry and exposure parameters for every x-ray pulse during a procedure. The data in the log files is input into PCXMC, a Monte Carlo program that calculates organ and effective dose for projections and exposure parameters set by the user. We developed a MATLAB program to readmore » data from the log files produced by the DTS and to automatically generate the definition files in the format used by PCXMC. The processing is done at the end of a procedure after all exposures are completed. Since there are thousands of exposure pulses with various parameters for fluoroscopy, DA and DSA and at various projections, the data for exposures with similar parameters is grouped prior to entry into PCXMC to reduce the number of Monte Carlo calculations that need to be performed. Results: The software developed automatically transfers data from the DTS log file to PCXMC and runs the program for each grouping of exposure pulses. When the dose from all exposure events are calculated, the doses for each organ and all effective doses are summed to obtain procedure totals. For a complicated interventional procedure, the calculations can be completed on a PC without manual intervention in less than 30 minutes depending on the level of data grouping. Conclusion: This system allows organ dose to be calculated for individual procedures for every patient without tedious calculations or data entry so that estimates of stochastic risk can be obtained in addition to the deterministic risk estimate provided by the DTS. Partial support from NIH grant R01EB002873 and Toshiba Medical Systems Corp.« less
OCCUPATIONAL RADIATION DOSES TO OPERATORS PERFORMING FLUOROSCOPICALLY-GUIDED PROCEDURES
Kim, Kwang Pyo; Miller, Donald L.; de Gonzalez, Amy Berrington; Balter, Stephen; Kleinerman, Ruth A.; Ostroumova, Evgenia; Simon, Steven L.; Linet, Martha S.
2012-01-01
In the past 30 years, the numbers and types of fluoroscopically-guided (FG) procedures have increased dramatically. The objective of the present study is to provide estimated radiation doses to physician specialists, other than cardiologists, who perform FG procedures. We searched Medline to identify English-language journal articles reporting radiation exposures to these physicians. We then identified several primarily therapeutic FG procedures that met specific criteria: well-defined procedures for which there were at least five published reports of estimated radiation doses to the operator, procedures performed frequently in current medical practice, and inclusion of physicians from multiple medical specialties. These procedures were percutaneous nephrolithotomy (PCNL), vertebroplasty, orthopedic extremity nailing for treatment of fractures, biliary tract procedures, transjugular intrahepatic portosystemic shunt creation (TIPS), head/neck endovascular therapeutic procedures, and endoscopic retrograde cholangiopancreatography (ERCP). We abstracted radiation doses and other associated data, and estimated effective dose to operators. Operators received estimated doses per patient procedure equivalent to doses received by interventional cardiologists. The estimated effective dose per case ranged from 1.7 – 56μSv for PCNL, 0.1 – 101 μSv for vertebroplasty, 2.5 – 88μSv for orthopedic extremity nailing, 2.0 – 46μSv for biliary tract procedures, 2.5 – 74μSv for TIPS, 1.8 – 53μSv for head/neck endovascular therapeutic procedures, and 0.2 – 49μSv for ERCP. Overall, mean operator radiation dose per case measured over personal protective devices at different anatomic sites on the head and body ranged from 19 – 800 (median = 113) μSv at eye level, 6 – 1180 (median = 75)μSv at the neck, and 2 – 1600 (median = 302) μSv at the trunk. Operators’ hands often received greater doses than the eyes, neck or trunk. Large variations in operator doses suggest that optimizing procedure protocols and proper use of protective devices and shields might reduce occupational radiation dose substantially. PMID:22647920
Economides, S; Hourdakis, C J; Kalivas, N; Kalathaki, M; Simantirakis, G; Tritakis, P; Manousaridis, G; Vogiatzi, S; Kipouros, P; Boziari, A; Kamenopoulou, V
2008-01-01
This study presents the results from a survey conducted by the Greek Atomic Energy Commission (GAEC), during the period 1998-2003, in 530 public and private owned fluoroscopic X-ray systems in Greece. Certain operational parameters for conventional and remote control systems were assessed, according to a quality control protocol developed by GAEC on the basis of the current literature. Public (91.5%) and private (81.5%) owned fluoroscopic units exhibit high-contrast resolution values over 1 lp mm(-1). Moreover, 88.5 and 87.1% of the fluoroscopic units installed in the public and private sector, respectively, present Maximum Patient Entrance Kerma Rate values lower than 100 mGy min(-1). Additionally, 68.3% of the units assessed were found to perform within the acceptance limits. Finally, the third quartile of the Entrance Surface Dose Rate distribution was estimated according to the Dose Reference Level definition and found equal to 35 mGy min(-1).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wunderle, K; Wayne State University School of Medicine, Detroit, MI; Godley, A
Purpose: The purpose of this investigation is to quantify various first half-value-layers (HVLs), second HVLs and homogeneity coefficients (HCs) for a state-of-the-art fluoroscope utilizing spectral (copper) filtration. Methods: A Radcal (Monrovia, Ca) AccuPro dosimeter with a 10×6-6 calibrated ionization chamber was used to measure air kerma for radiographic x-ray exposures made on a Siemens (Erlangen, Germany) Artis ZeeGo fluoroscope operated in the service mode. The ionization chamber was centered in the x-ray beam at 72 cm from the focal spot with a source-to-image-distance of 120 cm. The collimators were introduced to limit the x-ray field to approximately 5 cm ×more » 5 cm at the ionization chamber plane. Type-1100 aluminum filters, in 0.5 mm increments, were used to determine the HVL. Two HVL calculation methods were used, log-linear interpolation and Lambert-W interpolation as described by Mathieu [Med Phys, 38(8), 4546 (2011)]. Multiple measurements were made at 60, 80, 100, 120 kVp at spectral filtration thicknesses of 0, 0.1, 0.3, 0.6 and 0.9 mm. Results: First HVL, second HVL, and HCs are presented for the fluoroscopic x-ray beam spectra indicated above, with nearly identical results from the two interpolation methods. Accuracy of the set kVp was also determined and deviated less than 2%. First HVLs for fluoroscopic x-ray beam spectra without spectral filtration determined in our study were 7%–16% greater than previously published data by Fetterly et al. [Med Phys, 28, 205 (2001)]. However, the FDA minimum HVL requirements changed since that publication, requiring larger HVLs as of 2006. Additionally, x-ray tube and generator architecture have substantially changed over the last 15 years providing different beam spectra. Conclusion: X-ray beam quality characteristics for state-of-the-art fluoroscopes with spectral filtration have not been published. This study provides reference data which will be useful for defining beam qualities encountered on fluoroscopes using spectral filtration.« less
To, Justin; Aldape, Diana; Frost, Andrei; Goldberg, Gary L; Levie, Mark; Chudnoff, Scott
2014-10-01
To determine the efficacy of image-guided drainage versus antibiotic-only treatment of pelvic abscesses. Retrospective cohort analysis. An academic, inner-city medical center. Women ages 11-49, admitted between 1998 and 2008 with ICD9 code 614.x (inflammatory diseases of ovary, fallopian tube, pelvic cellular tissue, and peritoneum). Medical records search, chart review, and phone survey. Surgical intervention. We identified 6,151 initial patients, of whom 240 patients met inclusion criteria. Of the included patients, 199 women received antibiotic-only treatment, and 41 received additional image-guided drainage. There was no statistically significant difference between the two groups in terms of age, body mass index, parity, incidence of diabetes, obesity, endometriosis, or history of sexually transmitted infection excluding human immunodeficiency virus (HIV). Abscesses in the drainage cohort were noted to be larger in dimension (5.9 cm vs. 8.5 cm); 16.1% of patients who received antibiotics alone required surgical intervention versus only 2.4% of the drainage cohort. Patients who received drainage had longer hospital stays, but the time from treatment to discharge was similar in both groups (7.4 days vs. 6.7 days). We successfully contacted 150 patients, and the differences in long-term pregnancy outcomes, pain, or infertility were not statistically significant. Patients who received antibiotics alone were more likely to require further surgical intervention when compared with patients who additionally received image-guided drainage. There were no observable long-term differences. Copyright © 2014 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.
Fluoroscopic studies of the upper gastrointestinal tract: techniques and indications.
Sánchez-Carpintero de la Vega, M; García Villar, C
Fluoroscopic studies of the gastrointestinal tract are becoming increasing less common due to the introduction of other imaging techniques such as computed tomography and magnetic resonance imaging and to the increased availability of endoscopy. Nevertheless, fluoroscopic studies of the gastrointestinal tract continue to appear in clinical guidelines and some of their indications are still valid. These studies are dynamic, operator-dependent examinations that require training to obtain the maximum diagnostic performance. This review aims to describe the technique and bring the indications for this imaging modality up to date. Copyright © 2016 SERAM. Publicado por Elsevier España, S.L.U. All rights reserved.
Torsion of the normal fallopian tube.
Provost, M W
1972-01-01
From 1961 to 1970 a number of cases of torsion of the Fallopian tube were seen at the Kaiser Foundation Hospital in San Francisco of which 3 cases are reported. Of the many theories of causation, pelvic congestion seemed the most likely. The only universal symptom is pain, located in the quadrant of the affected tube and sometimes radiating to the thigh or flank. Nausea and vomiting are frequent; temperature and white cell count are only slightly elevated or normal. A mass is often felt, depending on the amount of hemorrhage. Correct diagnosis is almost never made preoperatively. The only treatment is laparotomy and surgical correction.
Mårdh, P A; Weström, L; von Mecklenburg, C; Hammar, E
1976-01-01
Organ cultures of human Fallopian tubes were infected with Mycoplasma hominis. Scanning and transmission electron microscopy revealed swelling of the cilia of the tubal epithelial cells in infected cultures. In some, the entire cilia were swollen; in others, only the tips. Uninfected cultures kept for up to 7 days showed no structural changes in the cilia or other surface structures. M. hominis multiplied in organ cultures, but not in culture medium without tissue. A practical organ culture technique for the preparation of specimens for electron microscopy is described. Images PMID:1260408
Efficacy of Yavakshara Taila Uttarabasti in the management of fallopian tube blockage.
Baria, Hetal P; Donga, Shilpa B; Dei, Laxmipriya
2015-01-01
Tubal blockage is one of the most common causative factors for female barrenness. It accounts for about 25-35% of female infertility. It is very difficult to manage, as the treatment choices for it are only tubal re-constructive surgery and in vitro fertilization (IVF). On the other hand, there is not established any reliable Ayurvedic treatment for the tubal blockage. It is the need of the time to establish an efficient and cost-effective therapy for this problem. To evaluate the efficacy of Yavakshara Taila Uttarabasti in fallopian tubal blockage. Patients of childbearing age with active marital life of 1 year or more, having complaint of failure to conceive with at least one fallopian tube blockage were selected. Total 19 patients were registered with 42.11% unilateral and 57.89% bilateral tubal blockage. Yavakshara Taila (5 ml) Intrauterine Uttarabasti was given for 6 days (with interval of 3 days in between), after completion of menstrual cycle for two consecutive cycles. The tubal patency was found in 68.75% of patients and conception was achieved in 6.25% of patients. Yavakshara Taila Uttarabasti an effective procedure for treating tubal blockage with no apparent evidence of complication.
Campagnolo, Marcelo Ivo; Reis, Ricardo Dos; Santos, Marcele Oliveira Dos; Kliemann, Lúcia Maria; Savaris, Ricardo Francalacci
2018-05-29
To determine which mode and potency of electrocoagulation, using a modern electrosurgical generator, yields the smallest unobstructed area of the Fallopian tubes. In an experimental study, tubes from 48 hysterectomies or tubal ligation were evaluated. Tubes were randomly allocated to one of the following groups: group A) 25 W x 5 seconds ( n = 17); group B) 30 W x 5 seconds ( n = 17); group C) 35 W x 5 seconds ( n = 18), group D) 40 W x 5 seconds ( n = 20); group E) 40 W x 5 seconds with visual inspection (blanch, swells, collapse) ( n = 16); group F) 50 W x 5 seconds ( n = 8). Bipolar electrocoagulation was performed in groups A to E, and monopolar electrocoagulation was performed in group F. Coagulation mode was used in all groups. Digital photomicrography of the transversal histological sections of the isthmic segment of the Fallopian tube were taken, and the median percentage of unobstructed luminal area (mm 2 ) was measured with ImageJ software (ImageJ, National Institutes of Health, Bethesda, MD, USA). The Kruskal-Wallis test or analysis of variance (ANOVA) was used for statistical analysis. Ninety-six Fallopian tube sections were analyzed. The smallest median occluded area (%; range) of the Fallopian tube was obtained in the group with 40 W with visual inspection (8.3%; 0.9-40%), followed by the groups 25 W (9.1%; 0-35.9%), 40 W (14.2; 0.9-43.2%), 30 W (14.2; 0.9-49.7%), 35 W (15.1; 3-46.4%) and 50 W (38.2; 3.1-51%). No statistically significant difference was found among groups ( p = 0.09, Kruskal-Wallis test). The smallest unobstructed area was obtained with power setting at 40 W with visual inspection using a modern electrosurgical generator. However, no statistically significant difference in the unobstructed area was observed among the groups using these different modes and potencies. Thieme Revinter Publicações Ltda Rio de Janeiro, Brazil.
Image Guidance Technologies for Interventional Pain Procedures: Ultrasound, Fluoroscopy, and CT.
Wang, Dajie
2018-01-26
Chronic pain is a common medical condition. Patients who suffer uncontrolled chronic pain may require interventions including spinal injections and various nerve blocks. Interventional procedures have evolved and improved over time since epidural injection was first introduced for low back pain and sciatica in 1901. One of the major contributors in the improvement of these interventions is the advancement of imaging guidance technologies. The utilization of image guidance has dramatically improved the accuracy and safety of these interventions. The first image guidance technology adopted by pain specialists was fluoroscopy. This was followed by CT and ultrasound. Fluoroscopy can be used to visualize bony structures of the spine. It is still the most commonly used guidance technology in spinal injections. In the recent years, ultrasound guidance has been increasingly adopted by interventionists to perform various injections. Because its ability to visualize soft tissue, vessels, and nerves, this guidance technology appears to be a better option than fluoroscopy for interventions including SGB and celiac plexus blocks, when visualization of the vessels may prevent intravascular injection. The current evidence indicates the efficacies of these interventions are similar between ultrasound guidance and fluoroscopy guidance for SGB and celiac plexus blocks. For facet injections and interlaminar epidural steroid injections, it is important to visualize bony structures in order to perform these procedures accurately and safely. It is worth noting that facet joint injections can be done under ultrasound guidance with equivalent efficacy to fluoroscopic guidance. However, obese patients may present challenge for ultrasound guidance due to its poor visualization of deep anatomical structures. Regarding transforaminal epidural steroid injections, there are limited evidence to support that ultrasound guidance technology has equivalent efficacy and less complications comparing to fluoroscopy. However, further studies are required to prove the efficacy of ultrasound-guided transforaminal epidural injections. SI joint is unique due to its multiplanar orientation, irregular joint gap, partial ankylosis, and thick dorsal and interosseous ligament. Therefore, it can be difficult to access the joint space with fluoroscopic guidance and ultrasound guidance. CT scan, with its cross-sectional images, can identify posterior joint gap, is most likely the best guidance technology for this intervention. Intercostal nerves lie in the subcostal grove close to the plural space. Significant risk of pneumothorax is associated with intercostal blocks. Ultrasound can provide visualization of ribs and pleura. Therefore, it may improve the accuracy of the injection and reduce the risk of pneumothorax. At present time, most pain specialists are familiar with fluoroscopic guidance techniques, and fluoroscopic machines are readily available in the pain clinics. In the contrast, CT guidance can only be performed in specially equipped facilities. Ultrasound machine is generally portable and inexpensive in comparison to CT scanner and fluoroscopic machine. As pain specialists continue to improve their patient care, ultrasound and CT guidance will undoubtedly be incorporated more into the pain management practice. This review is based on a paucity of clinical evidence to compare these guidance technologies; clearly, more clinical studies is needed to further elucidate the pro and cons of each guidance method for various pain management interventions.
Toward Simultaneous Real-Time Fluoroscopic and Nuclear Imaging in the Intervention Room.
Beijst, Casper; Elschot, Mattijs; Viergever, Max A; de Jong, Hugo W A M
2016-01-01
To investigate the technical feasibility of hybrid simultaneous fluoroscopic and nuclear imaging. An x-ray tube, an x-ray detector, and a gamma camera were positioned in one line, enabling imaging of the same field of view. Since a straightforward combination of these elements would block the lines of view, a gamma camera setup was developed to be able to view around the x-ray tube. A prototype was built by using a mobile C-arm and a gamma camera with a four-pinhole collimator. By using the prototype, test images were acquired and sensitivity, resolution, and coregistration error were analyzed. Nuclear images (two frames per second) were acquired simultaneously with fluoroscopic images. Depending on the distance from point source to detector, the system resolution was 1.5-1.9-cm full width at half maximum, the sensitivity was (0.6-1.5) × 10(-5) counts per decay, and the coregistration error was -0.13 to 0.15 cm. With good spatial and temporal alignment of both modalities throughout the field of view, fluoroscopic images can be shown in grayscale and corresponding nuclear images in color overlay. Measurements obtained with the hybrid imaging prototype device that combines simultaneous fluoroscopic and nuclear imaging of the same field of view have demonstrated the feasibility of real-time simultaneous hybrid imaging in the intervention room. © RSNA, 2015
MRI-guided and CT-guided cervical nerve root infiltration therapy: a cost comparison.
Maurer, M H; Froeling, V; Röttgen, R; Bretschneider, T; Hartwig, T; Disch, A C; de Bucourt, M; Hamm, B; Streitparth, F
2014-06-01
To evaluate and compare the costs of MRI-guided and CT-guided cervical nerve root infiltration for the minimally invasive treatment of radicular neck pain. Between September 2009 and April 2012, 22 patients (9 men, 13 women; mean age: 48.2 years) underwent MRI-guided (1.0 Tesla, Panorama HFO, Philips) single-site periradicular cervical nerve root infiltration with 40 mg triamcinolone acetonide. A further 64 patients (34 men, 30 women; mean age: 50.3 years) were treated under CT fluoroscopic guidance (Somatom Definition 64, Siemens). The mean overall costs were calculated as the sum of the prorated costs of equipment use (purchase, depreciation, maintenance, and energy costs), personnel costs and expenditure for disposables that were identified for MRI- and CT-guided procedures. Additionally, the cost of ultrasound guidance was calculated. The mean intervention time was 24.9 min. (range: 12 - 36 min.) for MRI-guided infiltration and 19.7 min. (range: 5 - 54 min.) for CT-guided infiltration. The average total costs per patient were EUR 240 for MRI-guided interventions and EUR 124 for CT-guided interventions. These were (MRI/CT guidance) EUR 150/60 for equipment use, EUR 46/40 for personnel, and EUR 44/25 for disposables. The mean overall cost of ultrasound guidance was EUR 76. Cervical nerve root infiltration using MRI guidance is still about twice as expensive as infiltration using CT guidance. However, since it does not involve radiation exposure for patients and personnel, MRI-guided nerve root infiltration may become a promising alternative to the CT-guided procedure, especially since a further price decrease is expected for MRI devices and MR-compatible disposables. In contrast, ultrasound remains the less expensive method for nerve root infiltration guidance. © Georg Thieme Verlag KG Stuttgart · New York.
21 CFR 892.1650 - Image-intensified fluoroscopic x-ray system.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Image-intensified fluoroscopic x-ray system. 892.1650 Section 892.1650 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... through electronic amplification. This generic type of device may include signal analysis and display...
21 CFR 892.1650 - Image-intensified fluoroscopic x-ray system.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Image-intensified fluoroscopic x-ray system. 892.1650 Section 892.1650 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... through electronic amplification. This generic type of device may include signal analysis and display...
21 CFR 892.1650 - Image-intensified fluoroscopic x-ray system.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Image-intensified fluoroscopic x-ray system. 892.1650 Section 892.1650 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... through electronic amplification. This generic type of device may include signal analysis and display...
Lacey, Matthew; Lamplot, Joseph; Walley, Kempland C; DeAngelis, Joseph P; Ramappa, Arun J
2017-05-18
To describe an approach to anterior cruciate ligament (ACL) reconstruction using autologous hamstring by drilling via the anteromedial portal in the presence of an intramedullary (IM) femoral nail. Once preoperative imagining has characterized the proposed location of the femoral tunnel preparations are made to remove all of the hardware (locking bolts and IM nail). A diagnostic arthroscopy is performed in the usual fashion addressing all intra-articular pathology. The ACL remnant and lateral wall soft tissues are removed from the intercondylar, to provide adequate visualization of the ACL footprint. Femoral tunnel placement is performed using a transportal ACL guide with desired offset and the knee flexed to 2.09 rad. The Beath pin is placed through the guide starting at the ACL's anatomic footprint using arthroscopic visualization and/or fluoroscopic guidance. If resistance is met while placing the Beath pin, the arthroscopy should be discontinued and the obstructing hardware should be removed under fluoroscopic guidance. When the Beath pin is successfully placed through the lateral femur, it is overdrilled with a 4.5 mm Endobutton drill. If the Endobutton drill is obstructed, the obstructing hardware should be removed under fluoroscopic guidance. In this case, the obstruction is more likely during Endobutton drilling due to its larger diameter and increased rigidity compared to the Beath pin. The femoral tunnel is then drilled using a best approximation of the graft's outer diameter. We recommend at least 7 mm diameter to minimize the risk of graft failure. Autologous hamstring grafts are generally between 6.8 and 8.6 mm in diameter. After reaming, the knee is flexed to 1.57 rad, the arthroscope placed through the anteromedial portal to confirm the femoral tunnel position, referencing the posterior wall and lateral cortex. For a quadrupled hamstring graft, the gracilis and semitendinosus tendons are then harvested in the standard fashion. The tendons are whip stitched, quadrupled and shaped to match the diameter of the prepared femoral tunnel. If the diameter of the patient's autologous hamstring graft is insufficient to fill the prepared femoral tunnel, the autograft may be supplemented with an allograft. The remainder of the reconstruction is performed according to surgeon preference. The presence of retained hardware presents a challenge for surgeons treating patients with knee instability. In cruciate ligament reconstruction, distal femoral and proximal tibial implants hardware may confound tunnel placement, making removal of hardware necessary, unless techniques are adopted to allow for anatomic placement of the graft. This report demonstrates how the femoral tunnel can be created using the anteromedial portal instead of a transtibial approach for reconstruction of the ACL.
ICRP special radiation protection issues in interventional radiology, digital and cardiac imaging.
Vano, E; Faulkner, K
2005-01-01
The International Commission on Radiological Protection (ICRP) has published two reports giving recommendations dealing with the avoidance of deterministic injuries in interventional radiology and the management of patient dose in digital radiology in 2001 and 2004, respectively. Another document, on radiation protection for cardiologists performing fluoroscopically guided procedures, will be produced during 2005. This paper highlights some of the topics of the published reports, their relevance to European legislation on medical exposures and the importance of radiation protection research in underpinning the ICRP task groups' work in to producing these documents. It is also anticipated that the results, obtained in the cardiology work package of the European research project, will be used in the new document on radiation protection for cardiologists.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ryan, E. Ronan, E-mail: ronan@ronanryan.com; Thornton, Raymond; Sofocleous, Constantinos T.
PurposeTo quantify radiation exposure to the primary operator and staff during PET/CT-guided interventional procedures.MethodsIn this prospective study, 12 patients underwent PET/CT-guided interventions over a 6 month period. Radiation exposure was measured for the primary operator, the radiology technologist, and the nurse anesthetist by means of optically stimulated luminescence dosimeters. Radiation exposure was correlated with the procedure time and the use of in-room image guidance (CT fluoroscopy or ultrasound).ResultsThe median effective dose was 0.02 (range 0-0.13) mSv for the primary operator, 0.01 (range 0-0.05) mSv for the nurse anesthetist, and 0.02 (range 0-0.05) mSv for the radiology technologist. The median extremitymore » dose equivalent for the operator was 0.05 (range 0-0.62) mSv. Radiation exposure correlated with procedure duration and with the use of in-room image guidance. The median operator effective dose for the procedure was 0.015 mSv when conventional biopsy mode CT was used, compared to 0.06 mSv for in-room image guidance, although this did not achieve statistical significance as a result of the small sample size (p = 0.06).ConclusionThe operator dose from PET/CT-guided procedures is not significantly different than typical doses from fluoroscopically guided procedures. The major determinant of radiation exposure to the operator from PET/CT-guided interventional procedures is time spent in close proximity to the patient.« less
Radiology-guided forceps biopsy and airway stenting in severe airway stenosis
Li, Zong-Ming; Wu, Gang; Han, Xin-Wei; Ren, Ke-Wei; Zhu, Ming
2014-01-01
PURPOSE We aimed to determine the feasibility, safety, and effectiveness of radiology-guided forceps biopsy and airway stenting in patients with severe airway stenosis. MATERIALS AND METHODS This study involved 28 patients with severe airway stenosis who underwent forceps biopsy between October 2006 and September 2011. Chest multislice computed tomography was used to determine the location and extent of stenosis. Sixteen patients had tracheal stenosis, two patients had stenosis of the tracheal carina, six patients had stenosis of the left main bronchus, and four patients had stenosis of the right main bronchus. Forceps biopsy and stenting of the stenosed area were performed under fluoroscopic guidance in digital subtraction angiography and the biopsy specimens were analyzed histopathologically. We contacted the patients via phone call and utilized a standardized questionnaire to determine their medical condition during a postoperative three-month follow-up. RESULTS The technical success rate of radiology-guided forceps biopsy was 100%. Biopsy specimens were obtained in all patients. Dyspnea was relieved immediately after stent placement. No serious complications, such as tracheal hemorrhage or perforation, mediastinal emphysema, or asphyxia, occurred. CONCLUSION Radiology-guided forceps biopsy and airway stenting can be used for the emergency treatment of severe airway stenosis. This method appears to be safe and effective, and it may be an alternative therapeutic option in patients who cannot tolerate fiberoptic bronchoscopy. PMID:24808434
Garnon, Julien; Koch, Guillaume; Ramamurthy, Nitin; Caudrelier, Jean; Rao, Pramod; Tsoumakidou, Georgia; Cazzato, Roberto Luigi; Gangi, Afshin
2016-09-01
To review our initial experience with percutaneous CT and fluoroscopy-guided screw fixation of pathological shoulder-girdle fractures. Between May 2014 and June 2015, three consecutive oncologic patients (mean age 65 years; range 57-75 years) with symptomatic pathological shoulder-girdle fractures unsuitable for surgery and radiotherapy underwent percutaneous image-guided screw fixation. Fractures occurred through metastases (n = 2) or a post-ablation cavity (n = 1). Mechanical properties of osteosynthesis were adjudged superior to stand-alone cementoplasty in each case. Cannulated screws were placed under combined CT and fluoroscopic guidance with complementary radiofrequency ablation or cementoplasty to optimise local palliation and secure screw fixation, respectively, in two cases. Follow-up was undertaken every few weeks until mortality or most recent appointment. Four pathological fractures were treated in three patients (2 acromion, 1 clavicular, 1 coracoid). Mean size of associated lesion was 2.6 cm (range 1-4.5 cm). Technical success was achieved in all cases (100 %), without complications. Good palliation and restoration of mobility were observed in two cases at 2-3 months; one case could not be followed due to early post-procedural oncologic mortality. Percutaneous image-guided shoulder-girdle osteosynthesis appears technically feasible with good short-term efficacy in this complex patient subset. Further studies are warranted to confirm these promising initial results.
Toward computer-assisted image-guided congenital heart defect repair: an initial phantom analysis.
Kwartowitz, David M; Mefleh, Fuad N; Baker, G Hamilton
2017-10-01
Radiation exposure in interventional cardiology is an important consideration, due to risk of cancer and other morbidity to the patient and clinical staff. Cardiac catheterizations rely heavily on fluoroscopic imaging exposing both patient and clinician to ionizing radiation. An image-guided surgery system capable of facilitating cardiac catheterizations was developed and tested to evaluate dose reduction. Several electromagnetically tracked tools were constructed specifically a 7-Fr catheter with five 5-degree-of-freedom magnetic seeds. Catheter guidance was accomplished using our image guidance system Kit for Navigation by Image-Focused Exploration and fluoroscopy alone. A cardiac phantom was designed and 3D printed to validate the image guidance procedure. In mock procedures, an expert clinician guided and deployed an occluder across the septal defect of the phantom heart. The image guidance method resulted in a dose of 1.26 mSv of radiation dose per procedure, while traditional guidance resulted in a dose of 3.33 mSv. Average overall dose savings for the image-guided method was nearly 2.07 mSv or 62 %. The work showed significant ([Formula: see text]) decrease in radiation dose with use of image guidance methods at the expense of a modest increase in procedure time. This study lays the groundwork for further exploration of image guidance applications in pediatric cardiology.
Scherman Rydhög, Jonas; Riisgaard de Blanck, Steen; Josipovic, Mirjana; Irming Jølck, Rasmus; Larsen, Klaus Richter; Clementsen, Paul; Lars Andersen, Thomas; Poulsen, Per Rugaard; Fredberg Persson, Gitte; Munck Af Rosenschold, Per
2017-04-01
The purpose of this study was to estimate the uncertainty in voluntary deep-inspiration breath-hold (DIBH) radiotherapy for locally advanced non-small cell lung cancer (NSCLC) patients. Perpendicular fluoroscopic movies were acquired in free breathing (FB) and DIBH during a course of visually guided DIBH radiotherapy of nine patients with NSCLC. Patients had liquid markers injected in mediastinal lymph nodes and primary tumours. Excursion, systematic- and random errors, and inter-breath-hold position uncertainty were investigated using an image based tracking algorithm. A mean reduction of 2-6mm in marker excursion in DIBH versus FB was seen in the anterior-posterior (AP), left-right (LR) and cranio-caudal (CC) directions. Lymph node motion during DIBH originated from cardiac motion. The systematic- (standard deviation (SD) of all the mean marker positions) and random errors (root-mean-square of the intra-BH SD) during DIBH were 0.5 and 0.3mm (AP), 0.5 and 0.3mm (LR), 0.8 and 0.4mm (CC), respectively. The mean inter-breath-hold shifts were -0.3mm (AP), -0.2mm (LR), and -0.2mm (CC). Intra- and inter-breath-hold uncertainty of tumours and lymph nodes were small in visually guided breath-hold radiotherapy of NSCLC. Target motion could be substantially reduced, but not eliminated, using visually guided DIBH. Copyright © 2017 Elsevier B.V. All rights reserved.
21 CFR 1020.31 - Radiographic equipment.
Code of Federal Regulations, 2012 CFR
2012-04-01
... fluoroscopic imaging or for recording images from the fluoroscopic image receptor, or computed tomography x-ray... and time, a preset number of pulses, or a preset radiation exposure to the image receptor. (i) Except... provided to indicate when the axis of the x-ray beam is perpendicular to the plane of the image receptor...
21 CFR 1020.31 - Radiographic equipment.
Code of Federal Regulations, 2013 CFR
2013-04-01
... fluoroscopic imaging or for recording images from the fluoroscopic image receptor, or computed tomography x-ray... and time, a preset number of pulses, or a preset radiation exposure to the image receptor. (i) Except... provided to indicate when the axis of the x-ray beam is perpendicular to the plane of the image receptor...
21 CFR 1020.31 - Radiographic equipment.
Code of Federal Regulations, 2014 CFR
2014-04-01
... fluoroscopic imaging or for recording images from the fluoroscopic image receptor, or computed tomography x-ray... and time, a preset number of pulses, or a preset radiation exposure to the image receptor. (i) Except... provided to indicate when the axis of the x-ray beam is perpendicular to the plane of the image receptor...
Angelova, Mariya Angelova; Kovachev, Emil Georgiev; Kisyov, Stefan Vasilev; Ivanova, Vilislava Robert
2015-01-01
The authors describe a case of a congenital Mullerian anomaly, uterus unicornis with missing right fallopian tube. An in Vitro Fertilization Pre-Embryo Transfer (IVF-ET) procedure was done and presently is known that the patient has left fallopian tube and left ovary, two kidneys, and right ovary is missing. No diagnostic laparoscopy and hysteroscopy were done, only hysterosalpingography (HSG) before the IVF procedure. Several days after the follicular puncture of the left ovary the patient was urgently admitted to the hospital for specialized gynaecology in Varna. Transabdominal ultrasonography showed right ovary atypically located immediately next to the liver and with emerging theca-lutein cysts. PMID:27275261
2016-01-01
Purposes. To present our series of 38 prone percutaneous nephrolithotomy procedures performed with renal access and tract dilation purely under ultrasound guidance and describe the benefits and challenges accompanying this approach. Methods. Thirty-eight consecutive patients presenting for percutaneous nephrolithotomy for renal stone removal were included in this prospective cohort study. Ultrasonographic imaging in the prone position was used to obtain percutaneous renal access and guide tract dilation. Fluoroscopic screening was used only for nephrostomy tube placement. Preoperative, intraoperative, and postoperative procedural and patient data were collected for analysis. Results. Mean age of patients was 52.7 ± 17.2 years. Forty-five percent of patients were male with mean BMI of 26.1 ± 7.3 and mean stone size of 27.2 ± 17.6 millimeters. Renal puncture was performed successfully with ultrasonographic guidance in all cases with mean puncture time of 135.4 ± 132.5 seconds. Mean dilation time was 11.5 ± 3.8 min and mean stone fragmentation time was 37.5 ± 29.0 min. Mean total operative time was 129.3 ± 41.1. No patients experienced any significant immediate postoperative complication. All patients were rendered stone-free and no additional secondary procedures were required. Conclusions. Ultrasound guidance for renal access and tract dilation in prone percutaneous nephrolithotomy is a feasible and effective technique. It can be performed safely with significantly reduced fluoroscopic radiation exposure to the patient, surgeon, and intraoperative personnel. PMID:27042176
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yang, Xiu-Jun, E-mail: woothingyang2008@126.com; Xing, Guang-Fu, E-mail: xgf8848@126.com
ObjectiveTo describe a new interventional technique to remove foreign bodies (FBs) embedded in soft tissues around vital vessels.MethodsUnder fluoroscopic guidance and using local anesthesia, percutaneous removal of FBs was performed using forceps in nine patients. All patients suffered from a metallic soft tissue FB located in close proximity to important vessels and one also had a small traumatic pseudoaneurysm adjacent to the FB. Prior to removal of the FB, the position of the nearest vessel was identified using a guide wire or catheter placed into the vessel. Balloon catheter was also simultaneously used to temporarily stop the blood flow ofmore » the nearest artery during the FB removal in three of the nine patients.ResultsAll of the nine FBs with 0–2 mm interval to the nearest vessel were successfully removed in the nine patients without any serious complications. The removed FBs measured 3–12 mm in length and 1–3 mm in width. The total fluoroscopic time of retrieval of each FB was 5–9 min (mean, 6.4 min). The volume of intraoperative bleeding ranged from 5 to 12 ml (mean, 7.5 ml). The length of hospital stay for each patient ranged from 4 to 8 days (mean, 5.5 days).ConclusionVascular intervention-aided percutaneous FB removal is minimally invasive and an effective method for removal of FBs around vital vessels.« less
Use of a retrievable metallic stent internally coated with silicone to treat airway obstruction.
Kim, Jin Hyoung; Shin, Ji Hoon; Song, Ho-Young; Lee, Se Chul; Kim, Kyung Rae; Park, Jung-Hoon
2008-08-01
The authors hypothesized that internally covered stents can reduce the rates of stent migration or mucous retention. The authors performed this study to report their experience with use of a retrievable metallic stent internally coated with silicone in patients with benign or malignant central airway obstructions. From 2004 to 2007, the authors performed fluoroscopically guided placement of a retrievable metallic stent internally coated with silicone in 26 consecutive patients with benign (n = 5) and malignant (n = 21) central airway obstructions. Stents were woven from a single thread of a 0.2-mm-diameter nitinol wire in a tubular configuration and internally covered with silicone membrane. Stent placement was technically and clinically successful in 93% (25/26) and 85% (22/26) of the patients, respectively. There were eight complications (31%) after stent placement, including tumor overgrowth (n = 2), stent migration (n = 1), symptomatic granulation tissue formation (n = 1), severe pain (n = 1), improper stent location (n = 1), symptomatic sputum retention (n = 1) and esophagobronchial fistula (n = 1). Because of complications, five stents were removed with a retrieval hook under fluoroscopic guidance without difficulty. The median survival period and stent patency were 150.0 days +/- 91.4 and 143.0 days +/- 26.7, respectively. The use of a retrievable metallic stent internally coated with silicone is a safe and effective method for relieving dyspnea, with adequate stent patency in patients with benign or malignant central airway obstructions. This stent design seems to be less prone to migration or mucous retention.
Fluoroscopic guidance for placing a double lumen endotracheal tube in adults.
Calenda, Emile; Baste, Jean Marc; Hajjej, Ridha; Rezig, Najiba; Moriceau, Jerome; Diallo, Yaya; Sghaeir, Slim; Danielou, Eric; Peillon, Christophe
2014-09-01
The aim of this study was to assess the right placement of the double lumen endotracheal tube with fluoroscopic guidance, which is used in first intention prior to the fiberscope in our institution. This was a prospective observational study. The study was conducted in vascular and thoracic operating rooms. We enrolled 205 patients scheduled for thoracic surgery, with ASA physical statuses of I (n = 37), II (n = 84), III (n = 80), and IV (n = 4). Thoracic procedures were biopsy (n = 20), wedge (n = 34), culminectomy (n = 6), lobectomy (n = 82), pneumonectomy (n = 4), sympathectomy (n = 9), symphysis (n = 47), and thymectomy (n = 3). The intubation with a double lumen tube was performed with the help of a laryngoscope. Tracheal and bronchial balloons were inflated and auscultation was performed after right and left exclusions. One shot was performed to locate the position of the bronchial tube and the hook. Fluoroscopic guidance was used to relocate the tube in case of a wrong position. When the fluoroscopic guidance failed to position the tube, a fiberscope was used. Perioperative collapse of the lung was assessed by the surgeon during the surgery. Correct fluoroscopic image was obtained after the first attempt in 58.5% of patients therefore a misplaced position was encountered in 41.5%. The fluoroscopic guidance allowed an exact repositioning in 99.5% of cases, and the mean duration of the procedure was 8 minutes. A fiberscope was required to move the hook for one patient. We did not notice a moving of the double lumen endotracheal tube during the surgery. The surgeon satisfaction was 100%. The fluoroscopy evidenced the right position of the double lumen tube and allowed a right repositioning in 99.5% of patients with a very simple implementation. Copyright © 2014. Published by Elsevier B.V.
Wunderle, Kevin A; Rakowski, Joseph T; Dong, Frank F
2016-05-08
The first goal of this study was to investigate the accuracy of the displayed reference plane air kerma (Ka,r) or air kerma-area product (Pk,a) over a broad spectrum of X-ray beam qualities on clinically used interventional fluoroscopes incorporating air kerma-area product meters (KAP meters) to measure X-ray output. The second goal was to investigate the accuracy of a correction coefficient (CC) determined at a single beam quality and applied to the measured Ka,r over a broad spectrum of beam qualities. Eleven state-of-the-art interventional fluoroscopes were evaluated, consisting of eight Siemens Artis zee and Artis Q systems and three Philips Allura FD systems. A separate calibrated 60 cc ionization chamber (external chamber) was used to determine the accuracy of the KAP meter over a broad range of clinically used beam qualities. For typical adult beam qualities, applying a single CC deter-mined at 100 kVp with copper (Cu) in the beam resulted in a deviation of < 5% due to beam quality variation. This result indicates that applying a CC determined using The American Association of Physicists in Medicine Task Group 190 protocol or a similar protocol provides very good accuracy as compared to the allowed ± 35% deviation of the KAP meter in this limited beam quality range. For interventional fluoroscopes dedicated to or routinely used to perform pediatric interventions, using a CC established with a low kVp (~ 55-60 kVp) and large amount of Cu filtration (~ 0.6-0.9 mm) may result in greater accuracy as compared to using the 100 kVp values. KAP meter responses indicate that fluoroscope vendors are likely normalizing or otherwise influencing the KAP meter output data. Although this may provide improved accuracy in some instances, there is the potential for large discrete errors to occur, and these errors may be difficult to identify.
Simultaneous fluoroscopic and nuclear imaging: impact of collimator choice on nuclear image quality.
van der Velden, Sandra; Beijst, Casper; Viergever, Max A; de Jong, Hugo W A M
2017-01-01
X-ray-guided oncological interventions could benefit from the availability of simultaneously acquired nuclear images during the procedure. To this end, a real-time, hybrid fluoroscopic and nuclear imaging device, consisting of an X-ray c-arm combined with gamma imaging capability, is currently being developed (Beijst C, Elschot M, Viergever MA, de Jong HW. Radiol. 2015;278:232-238). The setup comprises four gamma cameras placed adjacent to the X-ray tube. The four camera views are used to reconstruct an intermediate three-dimensional image, which is subsequently converted to a virtual nuclear projection image that overlaps with the X-ray image. The purpose of the present simulation study is to evaluate the impact of gamma camera collimator choice (parallel hole versus pinhole) on the quality of the virtual nuclear image. Simulation studies were performed with a digital image quality phantom including realistic noise and resolution effects, with a dynamic frame acquisition time of 1 s and a total activity of 150 MBq. Projections were simulated for 3, 5, and 7 mm pinholes and for three parallel hole collimators (low-energy all-purpose (LEAP), low-energy high-resolution (LEHR) and low-energy ultra-high-resolution (LEUHR)). Intermediate reconstruction was performed with maximum likelihood expectation-maximization (MLEM) with point spread function (PSF) modeling. In the virtual projection derived therefrom, contrast, noise level, and detectability were determined and compared with the ideal projection, that is, as if a gamma camera were located at the position of the X-ray detector. Furthermore, image deformations and spatial resolution were quantified. Additionally, simultaneous fluoroscopic and nuclear images of a sphere phantom were acquired with a physical prototype system and compared with the simulations. For small hot spots, contrast is comparable for all simulated collimators. Noise levels are, however, 3 to 8 times higher in pinhole geometries than in parallel hole geometries. This results in higher contrast-to-noise ratios for parallel hole geometries. Smaller spheres can thus be detected with parallel hole collimators than with pinhole collimators (17 mm vs 28 mm). Pinhole geometries show larger image deformations than parallel hole geometries. Spatial resolution varied between 1.25 cm for the 3 mm pinhole and 4 cm for the LEAP collimator. The simulation method was successfully validated by the experiments with the physical prototype. A real-time hybrid fluoroscopic and nuclear imaging device is currently being developed. Image quality of nuclear images obtained with different collimators was compared in terms of contrast, noise, and detectability. Parallel hole collimators showed lower noise and better detectability than pinhole collimators. © 2016 American Association of Physicists in Medicine.
Transthoracic needle biopsy of the lung
DiBardino, David M.; Yarmus, Lonny B.
2015-01-01
Background Image guided transthoracic needle aspiration (TTNA) is a valuable tool used for the diagnosis of countless thoracic diseases. Computed tomography (CT) is the most common imaging modality used for guidance followed by ultrasound (US) for lesions abutting the pleural surface. Novel approaches using virtual CT guidance have recently been introduced. The objective of this review is to examine the current literature for TTNA biopsy of the lung focusing on diagnostic accuracy and safety. Methods MEDLINE was searched from inception to October 2015 for all case series examining image guided TTNA. Articles focusing on fluoroscopic guidance as well as influence of rapid on-site evaluation (ROSE) on yield were excluded. The diagnostic accuracy, defined as the number of true positives divided by the number of biopsies done, as well as the complication rate [pneumothorax (PTX), bleeding] was examined for CT guided TTNA, US guided TTNA as well as CT guided electromagnetic navigational-TTNA (E-TTNA). Of the 490 articles recovered 75 were included in our analysis. Results The overall pooled diagnostic accuracy for CT guided TTNA using 48 articles that met the inclusion and exclusion criteria was 92.1% (9,567/10,383). A similar yield was obtained examining ten articles using US guided TTNA of 88.7% (446/503). E-TTNA, being a new modality, only had one pilot study citing a diagnostic accuracy of 83% (19/23). Pooled PTX and hemorrhage rates were 20.5% and 2.8% respectively for CT guided TTNA. The PTX rate was lower in US guided TTNA at a pooled rate of 4.4%. E-TTNA showed a similar rate of PTX at 20% with no incidence of bleeding in a single pilot study available. Conclusions Image guided TTNA is a safe and accurate modality for the biopsy of lung pathology. This study found similar yield and safety profiles with the three imaging modalities examined. PMID:26807279
Role of Fallopian Tubes in the Development of Ovarian Cancer.
Corzo, Camila; Iniesta, Maria D; Patrono, Maria Guadalupe; Lu, Karen H; Ramirez, Pedro T
2017-02-01
Ovarian cancer is the leading cause of death from gynecologic malignancy and the fifth cause of cancer death in women in the United States. The most common and lethal histologic subtype of epithelial ovarian cancer is high-grade serous carcinoma (HGSC), which generally presents at an advanced stage. HGSC may be associated with BRCA1 and BRCA2 mutations. Historically, HGSC was believed to originate from the ovarian epithelial cells. However, more recent evidence supports the idea that most ovarian cancers originate in the fallopian tube epithelium in both high-risk women and in the general population. Serous tubal intraepithelial carcinomas may ultimately evolve into ovarian or peritoneal cancer. As a result, prophylactic salpingectomy with conservation of the ovaries has become an increasingly more common practice for premenopausal women undergoing risk-reducing surgery. Because the fallopian tube is now recognized as the most common potential site of origin of ovarian carcinoma, there is ongoing research to explore molecular and genetic factors that may be critical in the development of this disease. Further research is needed to identify novel opportunities for early detection and screening of ovarian cancer with the ultimate goal of increasing overall survival. Copyright © 2016 AAGL. Published by Elsevier Inc. All rights reserved.
Noureldin, Mohamed Essam; Tawfik, Ahmed Mohamed; Shaker, Hassan S
2018-01-01
Background: Persistent Müllerian duct syndrome (PMDS) is not a common form of disorder of sex development in which Müllerian duct derivatives (fallopian tubes, uterus, and the proximal vagina) are present in an otherwise normally differentiated 46 XY male. In most of cases, the challenge comes in the procedure of orchiopexy. Case Presentation: We report a case of a 26-year-old man with PMDS. It was accidentally discovered when the patient presented to our outpatient clinic concerning about his empty scrotum as a premarital check. Diagnostic laparoscopy discovered Mullerian remnants in the form of uterus, cervix, and fallopian tubes with two attached testes to the fallopian tubes. Staged laparoscopic orchiopexy was done. We discuss the presentation, the management of this case in the literature, and our intervention. Conclusion: PMDS is not a common condition. Several concerns present in the management of these cases. Malignant transformation of the testis is the main risk facing those patients. Few literature studies discussed the risk of changing of these remnants into malignant tissue. Thus discussion with the patient, tissue histopathology, expert opinions, and literature review are the main clues in management of such cases.
Kamiyama, S; Miyagi, H; Kanazawa, K
2000-01-01
To determine the therapeutic value of selective salpingography (SSG) for infertile women with patent fallopian tubes. Retrospective, case-control analysis. University Hospital, infertility clinic. Infertile cases with patent tubes documented by hysterosalpingography (HSG) or by HSG followed by laparoscopic examination (n = 80). Hysteroscopic SSG. Patency rate of tubes by SSG. Pregnancy rate following SSG. Eighty cases were divided into the study group (SSG performed, 37 cases) and the case-control group (SSG not performed, 43 cases). Successful SSG of at least one tube was obtained in all of 37 cases (100%) in whom SSG was attempted. A patency rate of 95.9% was documented in the 73 cannulated tubes of these cases. The total subsequent pregnancy rate (48.6%) within 12 months of follow-up after SSG was significantly higher than that (11.6%) obtained in the control group (p < 0.001). The cumulative pregnancy rate in the study group was also significantly higher than that in the control group (p < 0.001). The findings of the present study encourage the application of SSG to infertile women, either as a sole therapeutic approach or in association with other methods of assisted reproductive technology, even if their fallopian tubes are shown to be patent by HSG. Copyright 2000 S. Karger AG, Basel
Roth, Anna; König, Peter; van Zandbergen, Ger; Klinger, Matthias; Hellwig-Bürgel, Thomas; Däubener, Walter; Bohlmann, Michael K; Rupp, Jan
2010-11-09
IFN-γ has an important role in the adaptive immune response against intracellular pathogens. In urogenital tract (UGT) infections with the obligate intracellular pathogen Chlamydia trachomatis, IFN-γ-mediated control of chlamydial growth implies the JAK-STAT signaling cascades and subsequent induction of the indoleamine 2,3-dioxygenase (IDO). As oxygen concentrations in the UGT are low under physiological conditions (O(2) < 5%) and further decrease during an inflammatory process, we wondered whether antibacterial properties of IFN-γ are maintained under hypoxic conditions. Using primary cells that were isolated from human fallopian tubes and an ex vivo human fallopian tube model (HFTM), we found that even high IFN-γ concentrations (200 units/mL) were not sufficient to limit growth of C. trachomatis under hypoxia. Reduced antibacterial activity of IFN-γ under hypoxia was restricted to the urogenital serovars D and L(2), but was not observed with the ocular serovar A. Impaired effectiveness of IFN-γ on chlamydial growth under hypoxia was accompanied by reduced phosphorylation of Stat-1 on Tyr701 and diminished IDO activity. This study shows that IFN-γ effector functions on intracellular C. trachomatis depend on the environmental oxygen supply, which could explain inadequate bacterial clearance and subsequent chronic infections eventually occurring in the UGT of women.
Zhao, Weihong; Zhu, Qian; Yan, Mingxing; Li, Cheng; Yuan, Jiangjing; Qin, Guojuan; Zhang, Jian
2015-02-01
Levonorgestrel, a derivative of progesterone, effectively protects women against unwanted pregnancy as an emergency contraceptive. Previous studies have not been successful in determining the mechanism by which levonorgestrel acts. In the present study we analysed cilia beat action and cilia morphology following levonorgestrel exposure in vitro and in vivo using both light and electron microscopy. There was a significant decrease in the ciliary beat frequency (CBF) of human fallopian tubes between mucosal explants bathed in 5 μmol/L levonorgestrel and those bathed in medium alone (P < 0.05). There was a tendency for CBF to decrease more in the ampulla than in isthmus, but there were no differences between the proliferative and secretory phases. In rat oviducts, levonorgestrel produced a similar reduction in CBF (~ 10%) compared with the saline control group (P < 0.05). Histological and ultrastructural analysis demonstrated no changes in the percentage of ciliated cells or in the classic '9 + 2' structure of cilia following levonorgestrel treatment in either system. Thus, levonorgestrel reduces CBF without damaging cilia morphology. Decreases in CBF may indicate a pathological role for levonorgestrel in the transportation of the ovum and zygote in the fallopian tube. © 2014 Wiley Publishing Asia Pty Ltd.
Fallopian tube prolapse following hysterectomy.
Fan, Qing-bo; Liu, Zhu-feng; Lang, Jing-he; Sun, Da-wei; Leng, Jin-hua; Zhu, Lan; Ning, Liu
2006-03-01
To investigate the clinical diagnosis, treatment, and prevention of fallopian tube prolapse (FTP) after hysterectomy. A total of 7949 patients received hysterectomy from January 1983 to August 2005 in Peking Union Medical College Hospital, and 9 cases (including 1 case from other hospital) of FTP after hysterectomy were involved during this period. All of them were diagnosed according to pathological results and were followed up. The symptoms, diagnosis, and treatment of the FTP patients were analyzed retrospectively. The incidence of FTP after hysterectomy was 0.1% (8/7949), with the incidence of FTP after transabdominal hysterectomy being 0.06% (4/6229), after trans-vaginal hysterectomy being 0.5% (4/780), after laparoscopic assistant vaginal hysterectomy being 0 (0/940). There was no symptom in 3 cases. The pelvic examination revealed the typical prolapsed fimbrial end of a fallopian tube in 3 cases and the other 6 cases revealed red granulation tissue. All of them were excised vaginally and cauterized. The results were proved by pathological examination. No recurrence was reported during follow-up. FTP is a rare complication after hysterectomy. The prognosis is well after proper diagnosis and treatment Fixation of accessories onto the pelvic wall and complete peritonealization at the time of hysterectomy are the most important methods to prevent FTP after hysterectomy.
Efficacy of Yavakshara Taila Uttarabasti in the management of fallopian tube blockage
Baria, Hetal P.; Donga, Shilpa B.; Dei, Laxmipriya
2015-01-01
Introduction: Tubal blockage is one of the most common causative factors for female barrenness. It accounts for about 25-35% of female infertility. It is very difficult to manage, as the treatment choices for it are only tubal re-constructive surgery and in vitro fertilization (IVF). On the other hand, there is not established any reliable Ayurvedic treatment for the tubal blockage. It is the need of the time to establish an efficient and cost-effective therapy for this problem. Aim: To evaluate the efficacy of Yavakshara Taila Uttarabasti in fallopian tubal blockage. Materials and Methods: Patients of childbearing age with active marital life of 1 year or more, having complaint of failure to conceive with at least one fallopian tube blockage were selected. Total 19 patients were registered with 42.11% unilateral and 57.89% bilateral tubal blockage. Yavakshara Taila (5 ml) Intrauterine Uttarabasti was given for 6 days (with interval of 3 days in between), after completion of menstrual cycle for two consecutive cycles. Results: The tubal patency was found in 68.75% of patients and conception was achieved in 6.25% of patients. Conclusion: Yavakshara Taila Uttarabasti an effective procedure for treating tubal blockage with no apparent evidence of complication. PMID:26730135
21 CFR 892.1660 - Non-image-intensified fluoroscopic x-ray system.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Non-image-intensified fluoroscopic x-ray system. 892.1660 Section 892.1660 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... of x-radiation into a visible image. This generic type of device may include signal analysis and...
21 CFR 892.1660 - Non-image-intensified fluoroscopic x-ray system.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Non-image-intensified fluoroscopic x-ray system. 892.1660 Section 892.1660 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... of x-radiation into a visible image. This generic type of device may include signal analysis and...
21 CFR 892.1660 - Non-image-intensified fluoroscopic x-ray system.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Non-image-intensified fluoroscopic x-ray system. 892.1660 Section 892.1660 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... of x-radiation into a visible image. This generic type of device may include signal analysis and...
28 CFR 552.13 - X-ray, major instrument, fluoroscope, or surgical intrusion.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 28 Judicial Administration 2 2010-07-01 2010-07-01 false X-ray, major instrument, fluoroscope, or... INSTITUTIONAL MANAGEMENT CUSTODY Searches of Housing Units, Inmates, and Inmate Work Areas § 552.13 X-ray, major... reasons only, with the inmate's consent. (b) The institution physician may authorize use of an X-ray for...
28 CFR 552.13 - X-ray, major instrument, fluoroscope, or surgical intrusion.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 28 Judicial Administration 2 2013-07-01 2013-07-01 false X-ray, major instrument, fluoroscope, or... INSTITUTIONAL MANAGEMENT CUSTODY Searches of Housing Units, Inmates, and Inmate Work Areas § 552.13 X-ray, major... reasons only, with the inmate's consent. (b) The institution physician may authorize use of an X-ray for...
28 CFR 552.13 - X-ray, major instrument, fluoroscope, or surgical intrusion.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 28 Judicial Administration 2 2014-07-01 2014-07-01 false X-ray, major instrument, fluoroscope, or... INSTITUTIONAL MANAGEMENT CUSTODY Searches of Housing Units, Inmates, and Inmate Work Areas § 552.13 X-ray, major... reasons only, with the inmate's consent. (b) The institution physician may authorize use of an X-ray for...
28 CFR 552.13 - X-ray, major instrument, fluoroscope, or surgical intrusion.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 28 Judicial Administration 2 2011-07-01 2011-07-01 false X-ray, major instrument, fluoroscope, or... INSTITUTIONAL MANAGEMENT CUSTODY Searches of Housing Units, Inmates, and Inmate Work Areas § 552.13 X-ray, major... reasons only, with the inmate's consent. (b) The institution physician may authorize use of an X-ray for...
28 CFR 552.13 - X-ray, major instrument, fluoroscope, or surgical intrusion.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 28 Judicial Administration 2 2012-07-01 2012-07-01 false X-ray, major instrument, fluoroscope, or... INSTITUTIONAL MANAGEMENT CUSTODY Searches of Housing Units, Inmates, and Inmate Work Areas § 552.13 X-ray, major... reasons only, with the inmate's consent. (b) The institution physician may authorize use of an X-ray for...
Transjugular intrahepatic portosystemic shunt creation using intravascular ultrasound guidance.
Farsad, Khashayar; Fuss, Cristina; Kolbeck, Kenneth J; Barton, Robert E; Lakin, Paul C; Keller, Frederick S; Kaufman, John A
2012-12-01
To describe the use of intravascular ultrasound (US) guidance for creation of transjugular intrahepatic portosystemic shunts (TIPSs) in humans. The initial 25 cases of intravascular US-guided TIPS were retrospectively compared versus the last 75 conventional TIPS cases during the same time period at the same institution in terms of the number of needle passes required to establish portal vein (PV) access, fluoroscopy time, and needle pass-related complications. Intravascular US-guided TIPS creation was successful in all cases, and there was no statistically significant difference in number of needle passes, fluoroscopy time, or needle pass-related complications between TIPS techniques. Intravascular US-guided TIPS creation was successful in cases in which conventional TIPS creation had failed as a result of PV thrombosis or distorted anatomy. Intravascular US guidance for TIPS creation was additionally useful in a patient with Budd-Chiari syndrome and in a patient with intrahepatic tumors. Intravascular US is a safe and reproducible means of real-time image guidance for TIPS creation, equivalent in efficacy to conventional fluoroscopic guidance. Real-time sonographic guidance with intravascular US may prove advantageous for cases in which there is PV thrombus, distorted anatomy, Budd-Chiari syndrome, or hepatic tumors. Copyright © 2012 SIR. Published by Elsevier Inc. All rights reserved.
Surgical Removal of Neglected Soft Tissue Foreign Bodies by Needle-Guided Technique
Ebrahimi, Ali; Radmanesh, Mohammad; Rabiei, Sohrab; kavoussi, Hossein
2013-01-01
Introduction: The phenomenon of neglected foreign bodies is a significant cause of morbidity in soft tissue injuries and may present to dermatologists as delayed wound healing, localized cellulitis and inflammation, abscess formation, or foreign body sensation. Localization and removal of neglected soft tissue foreign bodies (STFBs) is complex due to possible inflammation, indurations, granulated tissue, and fibrotic scar. This paper describes a simple method for the quick localization and (surgical) removal of neglected STFBs using two 23-gauge needles without ultrasonographic or fluoroscopic guidance. Materials and Methods: A technique based on the use of two 23-gauge needles was used in 41 neglected STFBs in order to achieve proper localization and fixation of foreign bodies during surgery. Results: Surgical removal was successful in 38 of 41 neglected STFBs (ranging from 2–13mm in diameter). Conclusion: The cross-needle-guided technique is an office-based procedure that allows the successful surgical removal of STFBs using minimal soft tissue exploration and dissection via proper localization, fixation, and propulsion of the foreign body toward the surface of the skin. PMID:24303416
Tubal pregnancy; Cervical pregnancy; Tubal ligation - ectopic pregnancy ... In most pregnancies, the fertilized egg travels through the fallopian tube to the womb (uterus). If the movement of the egg ...
Percutaneous coil embolization of massive pelvic pseudoaneurysm in an infant.
Lillis, Anna P; Shaikh, Raja; Alomari, Ahmad I; Chaudry, Gulraiz
2015-06-01
Iatrogenic pseudoaneurysm formation is an uncommon but potentially serious complication of cardiac catheterization. This case report describes diagnosis and treatment of a large left external iliac artery pseudoaneurysm in a 3-month-old boy following cardiac catheterization and aortic balloon dilatation for aortic coarctation. A 4-cm pulsatile mass in the left hemipelvis was discovered on MRI performed 6 weeks later for possible tethered spinal cord. Sonography and angiography showed a large pseudoaneurysm of the left external iliac artery just distal to the iliac bifurcation with no flow in the external iliac artery distal to the pseudoaneurysm. Percutaneous US-guided thrombin injection was performed twice, with partial recanalization after each treatment. The residual portion of the pseudoaneurysm was then successfully embolized with percutaneous coils deployed under US and fluoroscopic guidance.
The role of the fallopian tube in the origin of ovarian cancer
Erickson, Britt K.; Conner, Michael G.; Landen, Charles N.
2014-01-01
Advanced cases of epithelial ovarian, primary peritoneal, and primary tubal malignancies have a relatively poor prognosis and collectively remain the most deadly of all gynecologic malignancies. Although traditionally thought of as one disease process, ongoing research suggests that there is not 1 single site or cell type from which these cancers arise. A majority of the serous tumors appear to originate from dysplastic lesions in the distal fallopian tube. Therefore, what we have traditionally considered “ovarian” cancer may in fact be tubal in origin. In this article, we will review epithelial ovarian cancer classification and genetics, theories regarding cells of origin with a focus on tubal intraepithelial carcinoma, and implications for prevention and screening. PMID:23583217
Infertility caused by tubal blockage: An ayurvedic appraisal
Shukla (Upadhyaya), Kamayani; Karunagoda, Kaumadi; Dei, L. P.
2010-01-01
Tubal blockage is one of the most important factors for female infertility. This condition is not described in Ayurvedic classics, as the fallopian tube itself is not mentioned directly there. The present study is an effort to understand the disease according to Ayurvedic principles. Correlating fallopian tubes with the Artavavaha (Artava-bija-vaha) Srotas, its block is compared with the Sanga Srotodushti of this Srotas. Charak's opinion that the diseases are innumerable and newly discovered ones should be understood in terms of Prakriti, Adhishthana, Linga, and Aayatana, is followed, to describe this disease. An effort has been made to evaluate the role of all the three Doshas in producing blockage, with classification of the disease done as per the Dasha Roganika. PMID:22131704
Callahan, Michael J; Talmadge, Jennifer M; MacDougall, Robert D; Kleinman, Patricia L; Taylor, George A; Buonomo, Carlo
2017-04-01
In our experience, questions about the appropriate use of enteric contrast media for pediatric fluoroscopic studies are common. The purpose of this article is to provide a comprehensive review of enteric contrast media used for pediatric fluoroscopy, highlighting the routine use of these media at a large tertiary care pediatric teaching hospital.
Actual Time Required for Dynamic Fluoroscopic Intraoperative Cholangiography
Whitwam, Paul; Turner, David; Kennedy, Kathy; Hashmi, Syed
2005-01-01
Objectives: This study was undertaken to determine the actual amount of time a dynamic fluoroscopic intraoperative cholangiogram adds to a laparoscopic cholecystectomy. A secondary objective was to define the information gained from this procedure. Methods: A consecutive case study of 52 patients undergoing laparoscopic cholecystectomy was used. Time was recorded from placement of a laparoscopic hemoclip across the cystic duct at its junction with the gallbladder until successful completion of the intraoperative cholangiogram. The mean, median, and range of times for these cases, as well as the results and false-negative rates, were determined. Results: Cholangiography was successfully completed in 96% of patients. The mean time added to laparoscopic cholecystectomy by the addition of dynamic fluoroscopic intraoperative cholangiography was 4.3 minutes. The median time was 3.0 minutes. The times ranged from 2.0 minutes to 16.0 minutes. Choledocholithiasis was present in 15.4% of these patients. The false-positive rate was zero in this study. Conclusions: Dynamic fluoroscopic intraoperative cholangiogram was fast and efficient. The information gained was significant in that 15% of patients proceeded on to laparoscopic common bile duct exploration. We conclude that intraoperative cholangiography should be a routine addition to laparoscopic cholecystectomy. PMID:15984705
NASA Astrophysics Data System (ADS)
Davies, Andrew G.; Cowen, Arnold R.; Bruijns, Tom J. C.
1999-05-01
We are currently in an era of active development of the digital X-ray imaging detectors that will serve the radiological communities in the new millennium. The rigorous comparative physical evaluations of such devices are therefore becoming increasingly important from both the technical and clinical perspectives. The authors have been actively involved in the evaluation of a clinical demonstration version of a flat-panel dynamic digital X-ray image detector (or FDXD). Results of objective physical evaluation of this device have been presented elsewhere at this conference. The imaging performance of FDXD under radiographic exposure conditions have been previously reported, and in this paper a psychophysical evaluation of the FDXD detector operating under continuous fluoroscopic conditions is presented. The evaluation technique employed was the threshold contrast detail detectability (TCDD) technique, which enables image quality to be measured on devices operating in the clinical environment. This approach addresses image quality in the context of both the image acquisition and display processes, and uses human observers to measure performance. The Leeds test objects TO[10] and TO[10+] were used to obtain comparative measurements of performance on the FDXD and two digital spot fluorography (DSF) systems, one utilizing a Plumbicon camera and the other a state of the art CCD camera. Measurements were taken at a range of detector entrance exposure rates, namely 6, 12, 25 and 50 (mu) R/s. In order to facilitate comparisons between the systems, all fluoroscopic image processing such as noise reduction algorithms, were disabled during the experiments. At the highest dose rate FDXD significantly outperformed the DSF comparison systems in the TCDD comparisons. At 25 and 12 (mu) R/s all three-systems performed in an equivalent manner and at the lowest exposure rate FDXD was inferior to the two DSF systems. At standard fluoroscopic exposures, FDXD performed in an equivalent manner to the DSF systems for the TCDD comparisons. This would suggest that FDXD would therefore perform adequately in a clinical fluoroscopic environment and our initial clinical experiences support this. Noise reduction processing of the fluoroscopic data acquired on FDXD was also found to further improve TCDD performance for FDXD. FDXD therefore combines acceptable fluoroscopic performance with excellent radiographic (snap shot) imaging fidelity, allowing the possibility of a universal x-ray detector to be developed, based on FDXD's technology. It is also envisaged that fluoroscopic performance will be improved by the development of digital image enhancement techniques specifically tailored to the characteristics of the FDXD detector.
Ovarian, Fallopian Tube, and Primary Peritoneal Cancer Prevention
... early menopause. Symptoms of menopause include the following: Hot flashes . Night sweats. Trouble sleeping. Mood changes. Decreased sex drive . Heart disease. Vaginal dryness. Frequent urination. Osteoporosis ( ...
Computed tomography image-guided surgery in complex acetabular fractures.
Brown, G A; Willis, M C; Firoozbakhsh, K; Barmada, A; Tessman, C L; Montgomery, A
2000-01-01
Eleven complex acetabular fractures in 10 patients were treated by open reduction with internal fixation incorporating computed tomography image guided software intraoperatively. Each of the implants placed under image guidance was found to be accurate and without penetration of the pelvis or joint space. The setup time for the system was minimal. Accuracy in the range of 1 mm was found when registration was precise (eight cases) and was in the range of 3.5 mm when registration was only approximate (three cases). Added benefits included reduced intraoperative fluoroscopic time, less need for more extensive dissection, and obviation of additional surgical approaches in some cases. Compared with a series of similar fractures treated before this image guided series, the reduction in operative time was significant. For patients with complex anterior and posterior combined fractures, the average operation times with and without application of three-dimensional imaging technique were, respectively, 5 hours 15 minutes and 6 hours 14 minutes, revealing 16% less operative time for those who had surgery using image guidance. In the single column fracture group, the operation time for those with three-dimensional imaging application, was 2 hours 58 minutes and for those with traditional surgery, 3 hours 42 minutes, indicating 20% less operative time for those with imaging modality. Intraoperative computed tomography guided imagery was found to be an accurate and suitable method for use in the operative treatment of complex acetabular fractures with substantial displacement.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Garnon, Julien, E-mail: juliengarnon@gmail.com; Koch, Guillaume, E-mail: Guillaume.koch@gmail.com; Ramamurthy, Nitin, E-mail: Nitin-ramamurthy@hotmail.com
ObjectiveTo review our initial experience with percutaneous CT and fluoroscopy-guided screw fixation of pathological shoulder-girdle fractures.Materials and MethodsBetween May 2014 and June 2015, three consecutive oncologic patients (mean age 65 years; range 57–75 years) with symptomatic pathological shoulder-girdle fractures unsuitable for surgery and radiotherapy underwent percutaneous image-guided screw fixation. Fractures occurred through metastases (n = 2) or a post-ablation cavity (n = 1). Mechanical properties of osteosynthesis were adjudged superior to stand-alone cementoplasty in each case. Cannulated screws were placed under combined CT and fluoroscopic guidance with complementary radiofrequency ablation or cementoplasty to optimise local palliation and secure screw fixation, respectively, in two cases. Follow-up wasmore » undertaken every few weeks until mortality or most recent appointment.ResultsFour pathological fractures were treated in three patients (2 acromion, 1 clavicular, 1 coracoid). Mean size of associated lesion was 2.6 cm (range 1–4.5 cm). Technical success was achieved in all cases (100 %), without complications. Good palliation and restoration of mobility were observed in two cases at 2–3 months; one case could not be followed due to early post-procedural oncologic mortality.ConclusionPercutaneous image-guided shoulder-girdle osteosynthesis appears technically feasible with good short-term efficacy in this complex patient subset. Further studies are warranted to confirm these promising initial results.« less
HEU Holdup Measurements in the 321-M Draw Bench, Straightener, and Fluoroscope Components
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dewberry, R.A.
The Analytical Development Section of Savannah River Technology Center (SRTC) was requested by the Facilities Disposition Division (FDD) to determine the holdup of enriched uranium in the 321-M facility as part of an overall deactivation project of the facility. This report covers holdup measurements of uranium residue on the draw bench, straightener, and the fluoroscope components of the 321-M facility.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shiinoki, T; Shibuya, K; Sawada, A
Purpose: The new real-time tumor-tracking radiotherapy (RTRT) system was installed in our institution. This system consists of two x-ray tubes and color image intensifiers (I.I.s). The fiducial marker which was implanted near the tumor was tracked using color fluoroscopic images. However, the implantation of the fiducial marker is very invasive. Color fluoroscopic images enable to increase the recognition of the tumor. However, these images were not suitable to track the tumor without fiducial marker. The purpose of this study was to investigate the feasibility of markerless tracking using dual energy colored fluoroscopic images for real-time tumor-tracking radiotherapy system. Methods: Themore » colored fluoroscopic images of static and moving phantom that had the simulated tumor (30 mm diameter sphere) were experimentally acquired using the RTRT system. The programmable respiratory motion phantom was driven using the sinusoidal pattern in cranio-caudal direction (Amplitude: 20 mm, Time: 4 s). The x-ray condition was set to 55 kV, 50 mA and 105 kV, 50 mA for low energy and high energy, respectively. Dual energy images were calculated based on the weighted logarithmic subtraction of high and low energy images of RGB images. The usefulness of dual energy imaging for real-time tracking with an automated template image matching algorithm was investigated. Results: Our proposed dual energy subtraction improve the contrast between tumor and background to suppress the bone structure. For static phantom, our results showed that high tracking accuracy using dual energy subtraction images. For moving phantom, our results showed that good tracking accuracy using dual energy subtraction images. However, tracking accuracy was dependent on tumor position, tumor size and x-ray conditions. Conclusion: We indicated that feasibility of markerless tracking using dual energy fluoroscopic images for real-time tumor-tracking radiotherapy system. Furthermore, it is needed to investigate the tracking accuracy using proposed dual energy subtraction images for clinical cases.« less
den Boer, A; de Feyter, P J; Hummel, W A; Keane, D; Roelandt, J R
1994-06-01
Radiographic technology plays an integral role in interventional cardiology. The number of interventions continues to increase, and the associated radiation exposure to patients and personnel is of major concern. This study was undertaken to determine whether a newly developed x-ray tube deploying grid-switched pulsed fluoroscopy and extra beam filtering can achieve a reduction in radiation exposure while maintaining fluoroscopic images of high quality. Three fluoroscopic techniques were compared: continuous fluoroscopy, pulsed fluoroscopy, and a newly developed high-output pulsed fluoroscopy with extra filtering. To ascertain differences in the quality of images and to determine differences in patient entrance and investigator radiation exposure, the radiated volume curve was measured to determine the required high voltage levels (kVpeak) for different object sizes for each fluoroscopic mode. The fluoroscopic data of 124 patient procedures were combined. The data were analyzed for radiographic projections, image intensifier field size, and x-ray tube kilovoltage levels (kVpeak). On the basis of this analysis, a reference procedure was constructed. The reference procedure was tested on a phantom or dummy patient by all three fluoroscopic modes. The phantom was so designed that the kilovoltage requirements for each projection were comparable to those needed for the average patient. Radiation exposure of the operator and patient was measured during each mode. The patient entrance dose was measured in air, and the operator dose was measured by 18 dosimeters on a dummy operator. Pulsed compared with continuous fluoroscopy could be performed with improved image quality at lower kilovoltages. The patient entrance dose was reduced by 21% and the operator dose by 54%. High-output pulsed fluoroscopy with extra beam filtering compared with continuous fluoroscopy improved the image quality, lowered the kilovoltage requirements, and reduced the patient entrance dose by 55% and the operator dose by 69%. High-output pulsed fluoroscopy with a grid-switched tube and extra filtering improves the image quality and significantly reduces both the operator dose and patient dose.
The Ovary Is an Alternative Site of Origin for High-Grade Serous Ovarian Cancer in Mice
Coffey, Donna M.; Ma, Lang; Matzuk, Martin M.
2015-01-01
Although named “ovarian cancer,” it has been unclear whether the cancer actually arises from the ovary, especially for high-grade serous carcinoma (HGSC), also known as high-grade serous ovarian cancer, the most common and deadliest ovarian cancer. In addition, the tumor suppressor p53 is the most frequently mutated gene in HGSC. However, whether mutated p53 can cause HGSC remains unknown. In this study, we bred a p53 mutation, p53R172H, into conditional Dicer-Pten double-knockout (DKO) mice, a mouse model duplicating human HGSC, to generate triple-mutant (TKO) mice. Like DKO mice, these TKO mice develop metastatic HGSCs originating from the fallopian tube. Unlike DKO mice, however, even after fallopian tubes are removed in TKO mice, ovaries alone can develop metastatic HGSCs, indicating that a p53 mutation can drive HGSC arising from the ovary. To confirm this, we generated p53R172H-Pten double-mutant mice, one of the genetic control lines for TKO mice. As anticipated, these double-mutant mice also develop metastatic HGSCs from the ovary, verifying the HGSC-forming ability of ovaries with a p53 mutation. Our study therefore shows that ovaries harboring a p53 mutation, as well as fallopian tubes, can be a distinct tissue source of high-grade serous ovarian cancer in mice. PMID:25815421
The ovary is an alternative site of origin for high-grade serous ovarian cancer in mice.
Kim, Jaeyeon; Coffey, Donna M; Ma, Lang; Matzuk, Martin M
2015-06-01
Although named "ovarian cancer," it has been unclear whether the cancer actually arises from the ovary, especially for high-grade serous carcinoma (HGSC), also known as high-grade serous ovarian cancer, the most common and deadliest ovarian cancer. In addition, the tumor suppressor p53 is the most frequently mutated gene in HGSC. However, whether mutated p53 can cause HGSC remains unknown. In this study, we bred a p53 mutation, p53(R172H), into conditional Dicer-Pten double-knockout (DKO) mice, a mouse model duplicating human HGSC, to generate triple-mutant (TKO) mice. Like DKO mice, these TKO mice develop metastatic HGSCs originating from the fallopian tube. Unlike DKO mice, however, even after fallopian tubes are removed in TKO mice, ovaries alone can develop metastatic HGSCs, indicating that a p53 mutation can drive HGSC arising from the ovary. To confirm this, we generated p53(R172H)-Pten double-mutant mice, one of the genetic control lines for TKO mice. As anticipated, these double-mutant mice also develop metastatic HGSCs from the ovary, verifying the HGSC-forming ability of ovaries with a p53 mutation. Our study therefore shows that ovaries harboring a p53 mutation, as well as fallopian tubes, can be a distinct tissue source of high-grade serous ovarian cancer in mice.
Suprasert, Prapaporn; Manopunya, Manatsawee; Cheewakriangkrai, Chalong
2014-01-01
Single pegylated liposomal doxorubicin (PLD) is commonly used as a salvage treatment in platinum-resistant ovarian cancer, fallopian tube cancer and primary peritoneal adenocarcinoma (PPA) with a satisfactory outcome. However, the data for second generation PLD administered in this setting are still limited. We conducted a retrospective study to evaluate the outcome of patients who received single-agent second generation PLD (LIPO-DOX) after the development of clinical platinum resistance. The study period was between March 2008 and March 2013. LIPO-DOX was administered intravenously 40 mg/m2 every 28 days until disease progression, but for not more than six cycles. The response rate was evaluated using the Gynecologic Cancer Intergroup (GCIG) criteria while the toxicity was evaluated according to WHO criteria. Twenty-nine patients met the inclusion criteria in the study period with an overall response rate of 13.8%. The median progression free survival and overall survival were three and eleven months, respectively. With the total of 96 cycles of chemotherapy, the patients developed grades 3 and 4 hematologic toxicity as follows: anemia, 0%, leukopenia, 9.6%, neutropenia, 32.3% and thrombocytopenia, 0%. In conclusion, the single agent second generation PLD demonstrated modest efficacy in patients with platinum-resistant ovarian cancer, fallopian tube cancer and PPA without serious toxicity.
Roth, Anna; König, Peter; van Zandbergen, Ger; Klinger, Matthias; Hellwig-Bürgel, Thomas; Däubener, Walter; Bohlmann, Michael K.; Rupp, Jan
2010-01-01
IFN-γ has an important role in the adaptive immune response against intracellular pathogens. In urogenital tract (UGT) infections with the obligate intracellular pathogen Chlamydia trachomatis, IFN-γ–mediated control of chlamydial growth implies the JAK-STAT signaling cascades and subsequent induction of the indoleamine 2,3-dioxygenase (IDO). As oxygen concentrations in the UGT are low under physiological conditions (O2 < 5%) and further decrease during an inflammatory process, we wondered whether antibacterial properties of IFN-γ are maintained under hypoxic conditions. Using primary cells that were isolated from human fallopian tubes and an ex vivo human fallopian tube model (HFTM), we found that even high IFN-γ concentrations (200 units/mL) were not sufficient to limit growth of C. trachomatis under hypoxia. Reduced antibacterial activity of IFN-γ under hypoxia was restricted to the urogenital serovars D and L2, but was not observed with the ocular serovar A. Impaired effectiveness of IFN-γ on chlamydial growth under hypoxia was accompanied by reduced phosphorylation of Stat-1 on Tyr701 and diminished IDO activity. This study shows that IFN-γ effector functions on intracellular C. trachomatis depend on the environmental oxygen supply, which could explain inadequate bacterial clearance and subsequent chronic infections eventually occurring in the UGT of women. PMID:20974954
DOE Office of Scientific and Technical Information (OSTI.GOV)
Merritt, Z; Dave, J; Eschelman, D
Purpose: To investigate the effects of image receptor technology and dose reduction software on radiation dose estimates for most frequently performed fluoroscopically-guided interventional (FGI) procedures at a tertiary health care center. Methods: IRB approval was obtained for retrospective analysis of FGI procedures performed in the interventional radiology suites between January-2011 and December-2015. This included procedures performed using image-intensifier (II) based systems which were subsequently replaced, flat-panel-detector (FPD) based systems which were later upgraded with ClarityIQ dose reduction software (Philips Healthcare) and relatively new FPD system already equipped with ClarityIQ. Post procedure, technologists entered system-reported cumulative air kerma (CAK) and kerma-areamore » product (KAP; only KAP for II based systems) in RIS; these values were analyzed. Data pre-processing included correcting typographical errors and cross-verifying CAK and KAP. The most frequent high and low dose FGI procedures were identified and corresponding CAK and KAP values were compared. Results: Out of 27,251 procedures within this time period, most frequent high and low dose procedures were chemo/immuno-embolization (n=1967) and abscess drainage (n=1821). Mean KAP for embolization and abscess drainage procedures were 260,657, 310,304 and 94,908 mGycm{sup 2}, and 14,497, 15,040 and 6307 mGycm{sup 2} using II-, FPD- and FPD with ClarityIQ- based systems, respectively. Statistically significant differences were observed in KAP values for embolization procedures with respect to different systems but for abscess drainage procedures significant differences were only noted between systems with FPD and FPD with ClarityIQ (p<0.05). Mean CAK reduced significantly from 823 to 308 mGy and from 43 to 21 mGy for embolization and abscess drainage procedures, respectively, in transitioning to FPD systems with ClarityIQ (p<0.05). Conclusion: While transitioning from II- to FPD- based systems was not associated with dose reduction for the most frequently performed FGI procedures, substantial dose reduction was noted with relatively newer systems and dose reduction software.« less
Rouabah, K; Varoquaux, A; Caporossi, J M; Louis, G; Jacquier, A; Bartoli, J M; Moulin, G; Vidal, V
2016-11-01
The purpose of this study was to assess the feasibility and utility of image fusion (Easy-TIPS) obtained from pre-procedure CT angiography and per-procedure real-time fluoroscopy for portal vein puncture during transjugular intrahepatic portosystemic shunt (TIPS) placement. Eighteen patients (15 men, 3 women) with a mean age of 63 years (range: 48-81 years; median age, 65 years) were included in the study. All patients underwent TIPS placement by two groups of radiologists (one group with radiologists of an experience<3 years and one with an experience≥3 years) using fusion imaging obtained from three-dimensional computed tomography angiography of the portal vein and real-time fluoroscopic images of the portal vein. Image fusion was used to guide the portal vein puncture during TIPS placement. At the end of the procedure, the interventional radiologists evaluated the utility of fusion imaging for portal vein puncture during TIPS placement. Mismatch between three-dimensional computed tomography angiography and real-time fluoroscopic images of the portal vein on image fusion was quantitatively analyzed. Posttreatment CT time, number of the puncture attempts, total radiation exposure and radiation from the retrograde portography were also recorded. Image fusion was considered useful for portal vein puncture in 13/18 TIPS procedures (72%). The mean posttreatment time to obtain fusion images was 16.4minutes. 3D volume rendered CT angiography images was strictly superimposed on direct portography in 10/18 procedures (56%). The mismatch mean value was 0.69cm in height and 0.28cm laterally. A mean number of 4.6 portal vein puncture attempts was made. Eight patients required less than three attempts. The mean radiation dose from retrograde portography was 421.2dGy.cm 2 , corresponding to a mean additional exposure of 19%. Fusion imaging resulting from image fusion from pre-procedural CT angiography is feasible, safe and makes portal puncture easier during TIPS placement. Copyright © 2016 Editions françaises de radiologie. Published by Elsevier Masson SAS. All rights reserved.
Burns, Sean; Thornton, Raymond; Dauer, Lawrence T; Quinn, Brian; Miodownik, Daniel; Hak, David J
2013-07-17
Despite recommendations to do so, few orthopaedists wear leaded glasses when performing operative fluoroscopy. Radiation exposure to the ocular lens causes cataracts, and regulatory limits for maximum annual occupational exposure to the eye continue to be revised downward. Using anthropomorphic patient and surgeon phantoms, radiation dose at the surgeon phantom's lens was measured with and without leaded glasses during fluoroscopic acquisition of sixteen common pelvic and hip views. The magnitude of lens dose reduction from leaded glasses was calculated by dividing the unprotected dose by the dose measured behind leaded glasses. On average, the use of leaded glasses reduced radiation to the surgeon phantom's eye by tenfold, a 90% reduction in dose. However, there was widespread variation in the amount of radiation that reached the phantom surgeon's eye among the various radiographic projections we studied. Without leaded glasses, the dose measured at the surgeon's lens varied more than 250-fold among these sixteen different views. In addition to protecting the surgeon's eye from the deleterious effects of radiation, the use of leaded glasses could permit an orthopaedist to perform fluoroscopic views on up to ten times more patients before reaching the annual dose limit of 20 mSv of radiation to the eye recommended by the International Commission on Radiological Protection. Personal safety and adherence to limits of occupational radiation exposure should compel orthopaedists to wear leaded glasses for fluoroscopic procedures if other protective barriers are not in use. Leaded glasses are a powerful tool for reducing the orthopaedic surgeon's lens exposure to radiation during acquisition of common intraoperative fluoroscopic views.
Cost of a recall of a single-center experience managing the Riata defibrillator lead.
Hussain, Sarah; Moorman, Liza; Moorman, J Randall; DiMarco, John P; Malhotra, Rohit; Darby, Andrew; Bilchick, Kenneth; Mangrum, J Michael; Ferguson, John D; Mason, Pamela K
2015-01-15
Riata and Riata ST defibrillator leads (St. Jude Medical, Sylmar, California) were recalled in 2011 due to increased risk of insulation failure leading to externalized cables. Fluoroscopic screening can identify insulation failure, although the relation between mechanical failure and electrical failure is unclear. At the time of the recall, the University of Virginia developed a screening program, including fluoroscopic evaluation, education sessions, device interrogation, and remote monitoring for patients with this defibrillator lead. The aim of this study was to review the outcomes of the screening program, including costs, which were absorbed by our institution. Costs were calculated using Medicare reimbursement estimates. Forty-eight patients participated in the screening program. At initial screening, 31% were found to have evidence of insulation failure but electrical function was normal in all leads. The cost of this program was $35,358.72. The cost per diagnosis of mechanical lead failure was $2,357.25. During 2 years of follow-up, 1 patient experienced Riata lead electrical failure without fluoroscopic evidence of insulation failure. Patients were more likely to have a lead revision if there was evidence of insulation failure. Lead revisions occurred at the time of generator change in 88% of patients with insulation failure but in only 14% of patients with a fluoroscopically normal lead (p = 0.04). The cost of recall-related defibrillator lead revisions was $81,704.55. In conclusion, our Riata screening program added expense without clear benefit to patients. In fact, patients may have been put at more risk by undergoing defibrillator lead revisions based solely on the results of the fluoroscopic screening. Copyright © 2015 Elsevier Inc. All rights reserved.
Edge enhancement algorithm for low-dose X-ray fluoroscopic imaging.
Lee, Min Seok; Park, Chul Hee; Kang, Moon Gi
2017-12-01
Low-dose X-ray fluoroscopy has continually evolved to reduce radiation risk to patients during clinical diagnosis and surgery. However, the reduction in dose exposure causes quality degradation of the acquired images. In general, an X-ray device has a time-average pre-processor to remove the generated quantum noise. However, this pre-processor causes blurring and artifacts within the moving edge regions, and noise remains in the image. During high-pass filtering (HPF) to enhance edge detail, this noise in the image is amplified. In this study, a 2D edge enhancement algorithm comprising region adaptive HPF with the transient improvement (TI) method, as well as artifacts and noise reduction (ANR), was developed for degraded X-ray fluoroscopic images. The proposed method was applied in a static scene pre-processed by a low-dose X-ray fluoroscopy device. First, the sharpness of the X-ray image was improved using region adaptive HPF with the TI method, which facilitates sharpening of edge details without overshoot problems. Then, an ANR filter that uses an edge directional kernel was developed to remove the artifacts and noise that can occur during sharpening, while preserving edge details. The quantitative and qualitative results obtained by applying the developed method to low-dose X-ray fluoroscopic images and visually and numerically comparing the final images with images improved using conventional edge enhancement techniques indicate that the proposed method outperforms existing edge enhancement methods in terms of objective criteria and subjective visual perception of the actual X-ray fluoroscopic image. The developed edge enhancement algorithm performed well when applied to actual low-dose X-ray fluoroscopic images, not only by improving the sharpness, but also by removing artifacts and noise, including overshoot. Copyright © 2017 Elsevier B.V. All rights reserved.
Chiu, C K; Kwan, M K; Chan, C Y W; Schaefer, C; Hansen-Algenstaedt, N
2015-08-01
We undertook a retrospective study investigating the accuracy and safety of percutaneous pedicle screws placed under fluoroscopic guidance in the lumbosacral junction and lumbar spine. The CT scans of patients were chosen from two centres: European patients from University Medical Center Hamburg-Eppendorf, Germany, and Asian patients from the University of Malaya, Malaysia. Screw perforations were classified into grades 0, 1, 2 and 3. A total of 880 percutaneous pedicle screws from 203 patients were analysed: 614 screws from 144 European patients and 266 screws from 59 Asian patients. The mean age of the patients was 58.8 years (16 to 91) and there were 103 men and 100 women. The total rate of perforation was 9.9% (87 screws) with 7.4% grade 1, 2.0% grade 2 and 0.5% grade 3 perforations. The rate of perforation in Europeans was 10.4% and in Asians was 8.6%, with no significant difference between the two (p = 0.42). The rate of perforation was the highest in S1 (19.4%) followed by L5 (14.9%). The accuracy and safety of percutaneous pedicle screw placement are comparable to those cited in the literature for the open method of pedicle screw placement. Greater caution must be taken during the insertion of L5 and S1 percutaneous pedicle screws owing to their more angulated pedicles, the anatomical variations in their vertebral bodies and the morphology of the spinal canal at this location. ©2015 The British Editorial Society of Bone & Joint Surgery.
Koontz, Nicholas A; Wiggins, Richard H; Stoddard, Gregory J; Shah, Lubdha M
2017-10-01
There is a paucity of evidence-based literature regarding the advantages and disadvantages of the interlaminar approach and needle bevel orientation for performing a lumbar interlaminar epidural steroid injection (ESI). The purpose of this study was to determine if superior versus inferior lamina approach, needle bevel tip orientation, or both may predispose to inadvertent nonepidural penetration during lumbar interlaminar ESI. A prospective study was performed of patients with low back pain with or without radicular pain or neurogenic claudication referred for lumbar interlaminar ESI. Two hundred eleven patients were randomized by interlaminar approach (superior vs inferior) and bevel tip orientation (cranial vs caudal). Lumbar interlaminar ESI was performed by six interventionalists of varying levels of experience using fluoroscopic guidance with curved tip epidural needles, using loss-of-resistance technique and confirmation with contrast opacification. Exact Poisson regression was used to model the study outcome. Two hundred twenty-one lumbar interlaminar ESIs were performed on 211 patients, randomized to a superior (n = 121) or inferior lamina approach (n = 100) and to a cranial (n = 103) or caudal (n = 118) orientation of the bevel tip. Epidural needle placement was confirmed in 96.4% (n = 213) of cases. Nonepidural needle placement was most commonly associated with superior lamina approach and caudal bevel tip orientation, which was marginally significant (adjusted risk ratio, 6.88; 95% CI, 0.93-∞; p = 0.059). Inadvertent nonepidural needle penetration during fluoroscopically guided lumbar interlaminar ESI appears to be affected by approach, with superior lamina approach and caudal bevel tip orientation being the least favorable technique.
Jejunal feeding tubes can be efficiently and independently placed by intensive care unit teams.
Welpe, Pascal; Frutiger, Adrian; Vanek, Patrik; Kleger, Gian-Reto
2010-01-01
Nutrition support is an important therapeutic measure in critically ill patients. Several studies have shown that the enteral route is preferable to the parenteral route. Insertion of a feeding tube beyond the ligament of Treitz combined with continuous gastric drainage will reduce regurgitation and probably also the rate of nosocomial pneumonia. This study was conducted to assess the safety, success rate, and time required to establish jejunal nutrition by the fluoroscopy-guided technique in intensive care unit (ICU) patients. This was a prospective observational study in the ICUs of a 300-bed and a 600-bed community hospital. Indications were large gastric residuals during attempted gastric feeding, severe acute pancreatitis, or recurrent aspiration. Feeding tubes were introduced by the ICU staff at bedside under fluoroscopic guidance (a senior ICU physician and a resident or a registered ICU nurse). The correct jejunal position was documented by the application of a radiopaque contrast medium through the tube. After confirmation of the correct position, jejunal tube feeding was immediately started. The insertion procedure in 38 patients lasted a median of 17 minutes. The median time from decision to place the tube until start of enteral feeding was 141 minutes. The success rate was 84.2%. No adverse events were observed. Fluoroscopic placement of a jejunal feeding tube at the bedside is fast, is safe, and has a high success rate when performed by well-trained ICU staff. Using this method makes the ICU team more self-sufficient when critically ill patients require enteral nutrition and no gastroenterologist is available.
Saida, Tsukasa; Tanaka, Yumiko Oishi; Matsumoto, Koji; Satoh, Toyomi; Yoshikawa, Hiroyuki; Minami, Manabu
2016-02-01
Ovarian cancer is the seventh most common cancer diagnosis among women worldwide. The International Federation of Gynecology and Obstetrics recently significantly revised staging criteria for cancer of the ovary. The latest revision was based on the concept that high-grade serous tubal intraepithelial carcinoma (STIC) may be the origin of some high-grade serous carcinomas of the ovary and peritoneum. Therefore, staging criteria for the ovary, fallopian tube, and peritoneum have been unified. Understanding this background and other important revised points are essential for radiologists concerned with imaging diagnosis in gynecologic oncology. Through this review, we introduce the STIC theory and show examples of diseases in accordance with the new staging criteria based on magnetic resonance imaging (MRI) and computed tomography (CT) results.
Asaturova, A V; Ezhova, L S; Faizullina, N M; Adamyan, L V; Khabas, G N; Sannikova, M V
to investigate the frequency of the types of fallopian tubal secretory cell expansion (SCE) in diseases of the reproductive organs and to determine the immunophenotype and biological role of the cells in the early stages of the pathogenesis of high-grade ovarian serous carcinomas (HGOSC). The investigation enrolled 287 patients with extraovarian diseases and ovarian serous tumors varying in grade, whose fallopian tubes were morphologically and immunohistochemically examined using p53, Ki-67, PAX2, Bcl-2, beta-catenin, and ALDH1 markers. The material was statistically processed applying the Mann-Whitney test and χ2 test. The rate of secretory cell proliferation (SCP) (more than 10 consecutive secretory cells) and that of secretory cell overgrowth (SCO) (more than 30 consecutive secretory cells) increase with age in all investigated reproductive system diseases. The rate of SCP in the corpus fimbriatum of the patients with HGOSC was 5.9 times higher than that in those with extraovarian disease (p<0.01); when comparing the same patient groups, that of SCO was 3.4 times higher (p<0.05). The immunohistochemical characteristics of the investigated lesions (in scores) were as follows: PAX2 was expressed in the intact epithelium (2.8), in SCP (1.3), in SCO (1.2), in serous tubal intraepithelial carcinoma (STIC) (1.0), and in HGOSC (0.9); Bcl-2 was in the intact epithelium (2.2), in SCP (2.1), STIC (0.9), and in HGOSC (0.6), β-catenin was in the intact epithelium (0.5), in SCP (2.85), in SCO (2.95), in STIC (0.6), and in HGOSC (0.5); ALDH1 was in the intact epithelium (0.5), in SCP (2.91), in SCO (2.92), in STIC (1.2), and in HGOSC (0.6). There were statistically significant differences with a 95% confidence interval (p<0.05) for: 1) PAX2 between the intact epithelium and pathology (fallopian tube lesions and HGOSC); 2) Bcl-2 between the intact epithelium and SCE (SCP and SCO) and between SCE and HGOSC; 3) beta-catenin between the intact epithelium and SCE (SCP and SCO) and between SCE and HGOSC; 4) ALDH1 between the intact epithelium and SCE, between and SCE and STIC, and between STIC and HGOSC. SCE was shown to be an independent intraepithelial lesion. The incidence of this abnormality increased with age and significantly differed in the patients with fallopian tubal lesions in extraovarian diseases from that in those with malignant ovarian serous tumors (by 5.3 times), while these groups showed a three-fold difference in SCO. Thus, SCP may serve as a more sensitive marker for the early stages of the pathogenesis of ovarian serous carcinoma. The studied types of SCE demonstrated multiple molecular events (loss of PAX2 expression and increased Bcl-2, beta-catenin, and ALDH1 expressions), some of which underwent considerable changes, by increasing the severity of a pathological process (loss of ALDH1, and beta-catenin, and bcl-2 expressions). Thus, therapeutic exposure in the early stages of pathogenesis may have a few points of application and just several molecules can serve as independent markers for early pathological changes in the fallopian tubal epithelium.
Automated quantification of lumbar vertebral kinematics from dynamic fluoroscopic sequences
NASA Astrophysics Data System (ADS)
Camp, Jon; Zhao, Kristin; Morel, Etienne; White, Dan; Magnuson, Dixon; Gay, Ralph; An, Kai-Nan; Robb, Richard
2009-02-01
We hypothesize that the vertebra-to-vertebra patterns of spinal flexion and extension motion of persons with lower back pain will differ from those of persons who are pain-free. Thus, it is our goal to measure the motion of individual lumbar vertebrae noninvasively from dynamic fluoroscopic sequences. Two-dimensional normalized mutual information-based image registration was used to track frame-to-frame motion. Software was developed that required the operator to identify each vertebra on the first frame of the sequence using a four-point "caliper" placed at the posterior and anterior edges of the inferior and superior end plates of the target vertebrae. The program then resolved the individual motions of each vertebra independently throughout the entire sequence. To validate the technique, 6 cadaveric lumbar spine specimens were potted in polymethylmethacrylate and instrumented with optoelectric sensors. The specimens were then placed in a custom dynamic spine simulator and moved through flexion-extension cycles while kinematic data and fluoroscopic sequences were simultaneously acquired. We found strong correlation between the absolute flexionextension range of motion of each vertebra as recorded by the optoelectric system and as determined from the fluoroscopic sequence via registration. We conclude that this method is a viable way of noninvasively assessing twodimensional vertebral motion.
Hong, Seong Sook; Kim, Ah Young; Kwon, Seok Beom; Kim, Pyo Nyun; Lee, Moon-Gyu; Ha, Hyun Kwon
2010-10-01
To evaluate the feasibility of 3D CT enterography using oral gastrografin in patients with small bowel obstruction (SBO), focusing on improving diagnostic performance as compared with the use of axial CT imagings and fluoroscopic findings. For a 10-month period, 18 patients with known SBO detected clinically and radiologically were enrolled. In all patients, gastrografin was ingested prior to CT enterography. Twelve patients underwent a fluoroscopic examination. Images were randomly assessed for confidence for the level, for the cause of SBO, and for the assessment of the interpretability of each image by two gastrointestinal radiologists. The results were considered statistically significant using the Wilcoxon rank sum test. All patients (100%) well tolerated the administration of oral gastrografin. The use of 3D CT enterography significantly improved diagnostic confidence for the interpretation of the level, cause of SBO, and the assessment of the interpretability of each image as compared with the use of axial CT images (P < 0.05). 3D CT enterography was superior as compared to fluoroscopic examination (P < 0.05). The use of gastrografin for 3D CT enterography is a safe and feasible technique for precise evaluation of known or suspected SBO.
Resnick, Daniel K
2003-06-01
Fluoroscopy-based frameless stereotactic systems provide feedback to the surgeon using virtual fluoroscopic images. The real-life accuracy of these virtual images has not been compared with traditional fluoroscopy in a clinical setting. We prospectively studied 23 consecutive cases. In two cases, registration errors precluded the use of virtual fluoroscopy. Pedicle probes placed with virtual fluoroscopic imaging were imaged with traditional fluoroscopy in the remaining 21 cases. Position of the probes was judged to be ideal, acceptable but not ideal, or not acceptable based on the traditional fluoroscopic images. Virtual fluoroscopy was used to place probes in for 97 pedicles from L1 to the sacrum. Eighty-eight probes were judged to be in ideal position, eight were judged to be acceptable but not ideal, and one probe was judged to be in an unacceptable position. This probe was angled toward an adjacent disc space. Therefore, 96 of 97 probes placed using virtual fluoroscopy were found to be in an acceptable position. The positive predictive value for acceptable screw placement with virtual fluoroscopy compared with traditional fluoroscopy was 99%. A probe placed with virtual fluoroscopic guidance will be judged to be in an acceptable position when imaged with traditional fluoroscopy 99% of the time.
Levonorgestrel Intrauterine System
... Levonorgestrel may also prevent ovulation (release of an egg from the ovaries) in some women. Levonorgestrel intrauterine ... problem with your fallopian tubes (tubes that transport eggs that have been released by the ovaries to ...
... estrogen causes the endometrium to become thick and rich with blood. Progesterone, another hormone released by the ... doesn't travel into the uterus, but instead grows rapidly in the fallopian tube. A woman with ...
21 CFR 884.4100 - Endoscopic electrocautery and accessories.
Code of Federal Regulations, 2012 CFR
2012-04-01
... coagulate fallopian tube tissue with a probe heated by low-voltage energy. This generic type of device may include the following accessories: electrical generators, probes, and electrical cables. (b...
21 CFR 884.4100 - Endoscopic electrocautery and accessories.
Code of Federal Regulations, 2014 CFR
2014-04-01
... coagulate fallopian tube tissue with a probe heated by low-voltage energy. This generic type of device may include the following accessories: electrical generators, probes, and electrical cables. (b...
21 CFR 884.4100 - Endoscopic electrocautery and accessories.
Code of Federal Regulations, 2013 CFR
2013-04-01
... coagulate fallopian tube tissue with a probe heated by low-voltage energy. This generic type of device may include the following accessories: electrical generators, probes, and electrical cables. (b...
21 CFR 884.4100 - Endoscopic electrocautery and accessories.
Code of Federal Regulations, 2011 CFR
2011-04-01
... coagulate fallopian tube tissue with a probe heated by low-voltage energy. This generic type of device may include the following accessories: electrical generators, probes, and electrical cables. (b...
Mulvaney, Sean W
2009-01-01
Viscosupplementation of the hip for symptomatic osteoarthritis appears to be safe and effective in more than 25 yr of use in Europe. More than 11 studies suggest that viscosupplementation in the hip is as effective as viscosupplementation in the knee. It appears to be a safe and reasonable alternative to nonsteroidal antiinflammatory drugs or intra-articular steroids for the treatment of osteoarthritis pain. Viscosupplementation in the hip may delay the need for hip replacement surgery. Viscosupplementation in the hip appears to work better in patients with fewer radiographic changes of osteoarthritis. Placement of viscosupplement in the hip under real-time ultrasound or fluoroscopic guidance is safe and well tolerated. Hip joint communication with the iliopsoas bursa may be a factor in studies of the effectiveness of viscosupplementation in the hip.
Malignant biliary disease: percutaneous interventions.
Morgan, R A; Adam, A N
2001-09-01
Interventional radiologists have an important role in the management of patients with malignant biliary obstruction. This article describes the techniques for percutaneous biliary drainage, insertion of biliary endoprostheses, and the management of occluded biliary endoprostheses. Most procedures are performed by using fluoroscopic guidance alone. Ultrasound is also a useful modality for guiding biliary drainage, particularly drainage of the left biliary ducts. Patients should be treated by internal drainage if possible. Metallic endoprostheses can be inserted at the time of the initial biliary drainage procedure. Plastic tubes should be inserted a few days after biliary drainage because of their relatively large size compared with metallic stents. Occluded plastic stents should be replaced. Blocked metallic stents should be treated either by placement of additional overlapping metallic stents or by placement of plastic stents within the metallic stent lumen. Copyright 2001 by W.B. Saunders Company
History and Evolution of the Barium Swallow for Evaluation of the Pharynx and Esophagus.
Levine, Marc S; Rubesin, Stephen E
2017-02-01
This article reviews the history of the barium swallow from its early role in radiology to its current status as an important diagnostic test in modern radiology practice. Though a variety of diagnostic procedures can be performed to evaluate patients with dysphagia or other pharyngeal or esophageal symptoms, the barium study has evolved into a readily available, non-invasive, and cost-effective technique that can facilitate the selection of additional diagnostic tests and guide decisions about medical, endoscopic, or surgical management. This article focuses on the evolution of fluoroscopic equipment, radiography, and contrast media for evaluating the pharynx and esophagus, the importance of understanding pharyngoesophageal relationships, and major advances that have occurred in the radiologic diagnosis of select esophageal diseases, including gastroesophageal reflux disease, infectious esophagitis, eosinophilic esophagitis, esophageal carcinoma, and esophageal motility disorders.
SU-E-J-56: Static Gantry Digital Tomosynthesis From the Beam’s-Eye-View
DOE Office of Scientific and Technical Information (OSTI.GOV)
Partain, L; Kwon, J; Boyd, D
Purpose We have designed a novel TumoTrak™ x-ray system that delivers 19 distinct kV views with the linac gantry stationary. It images MV treatment beam above and below the patient with a kV tomosysthesis slice image from the therapy beam’s-eye-view. Results will be high quality images without MLC shadowing for notable improvements relative to conventional fluoroscopic MV imaging and fluoroscopic kV imaging. Methods A complete design has a kV electron beam multisource X-ray tube that fits around the MV treatment beam path, with little interference with normal radiotherapy and unblocked by the multi-leaf-collimator. To simulate digital tomosynthesis, we used cone-beammore » CT projection data from a lung SBRT patient. These data were acquired at 125 kVp and 11 fps (0.4 mAs per projection). We chose 19 projections evenly spaced over 27° around one of the treatment angles (240°). Digital tomosynthesis reconstruction of a slice through the tumor was performed using iterative reconstruction. The visibility of the lesion was assessed for the reconstructed digital tomosynthesis (DTS), using fluoroscopy MV images acquired during radiation therapy, and a kV single projection image acquired at the same angle as the treatment field (240°). Results The fluoroscopic DTS images provide the best tumor contrast, surpassing the conventional radiographic and the in-treatment MV portal images. The electron beam multisource X-ray tube design has been completed and the tube is being fabricated. The estimated time to cycle through all 19 projections is 700 ms, enabling high frame-rate imaging. While the initial proposed use case is for image guided and gated treatment delivery, the enhanced imaging will also deliver superior radiographic images for patient setup. Conclusion The proposed device will deliver high quality planar images from the beam’s-eye-view without MLC obstruction. The prototype has been designed and is being assembled with first imaging scheduled for May 2015. L. Partain, J. Kwon, D. Boyd: NIH/SBIR R43CA192489-01. J. Rottmann, G. Zentai, R. Berbeco: NIH/NCI 1R01CA188446-01. R. Berbeco: E. Research Grant, Varian Medical Systems.« less
Wolfschmidt, Franziska; Hassold, Nicole; Goltz, Jan Peter; Leyh, Rainer; Bley, Thorsten Alexander; Kickuth, Ralph
2015-09-01
To evaluate the feasibility, effectiveness, and safety of using a commercially available reentry catheter with fluoroscopic guidance to gain controlled target lumen reentry for fenestration in patients with aortic dissection. This retrospective study was approved by the local institutional review board; informed consent was waived. Between April 2009 and December 2013, 13 consecutive patients (10 men and three women; mean age, 51.2 years; range, 30.0-77.0 years; mean age of women, 47.0 years; range, 30.0-69.0 years; mean age of men, 52.4 years; range, 35.0-77.0 years) with aortic dissection and spinal (n = 4), renal (n = 7), mesenteric (n = 2), and/or iliofemoral (n = 9) malperfusion syndrome were included. All patients received target lumen reentry by means of balloon fenestration of the aortic dissection flap. A reentry catheter was used for fluoroscopically guided puncture of the target lumen. Technical success, clinical outcome, Stanford type of dissection, procedure time, number of fenestrations of the intimal flap per patient, necessity of additional aortic stent-graft implantation and/or placement of a bare metal stent, complications, and follow-up images were evaluated. Pre- and postinterventional systolic blood pressure gradients between the true lumen and the false lumen were compared (Wilcoxon signed-rank test). Safety of the reentry catheter maneuver was estimated with the Clopper-Pearson method. Use of the reentry catheter was technically successful in all 13 (100%) patients and clinically successful in 10 of 13 (77%) patients. Four patients had type A and nine had type B dissection. The mean clinical follow-up period was 14.2 months. Median procedure time was 71 minutes. In four patients, fenestration of the intimal flap was performed twice. Three patients underwent additional aortic stent grafting, four patients underwent placement of an iliofemoral stent, and one patient underwent placement of a carotid artery stent. Blood pressure gradients between the true lumen and the false lumen were significantly reduced (P = .0313). One patient who had a combination of syndromes died of multiorgan failure. The applied commercially available reentry catheter seems to be a reliable and safe tool that may be useful for gaining target lumen reentry with reasonably good clinical outcomes.
Fallopian Tubes: Is Pregnancy Possible with Only One?
... of Privacy Practices Notice of Nondiscrimination Manage Cookies Advertising Mayo Clinic is a not-for-profit organization and proceeds from Web advertising help support our mission. Mayo Clinic does not ...
Sharma, Jai Bhagwan; Sneha, Jayaramaiah; Singh, Urvashi B; Kumar, Sunesh; Roy, Kallol Kumar; Singh, Neeta; Dharmendra, Sona; Vanamail, Perumal
2016-02-01
To study the effect of antitubercular treatment (ATT) on the laparoscopic abdominopelvic and fallopian tube findings in female genital tuberculosis (FGBT). Prospective cohort (Canadian Task Force classification II2). Tertiary referral center in northern India. Fifty women with infertility and diagnosed with FGTB on laparoscopy, histopathology findings, or endometrial sampling (acid-fast bacilli culture, granuloma on histopathology, positive polymerase chain reaction). Diagnostic laparoscopy in all women diagnosed with FGTB before and after a 6-month course of ATT (2 months of rifampicin, isoniazid, pyrazinamide, and ethambutol, followed by 4 months of rifampicin and isoniazid). All procedures were performed by the same surgeon between June 2012 and May 2014. The mean patient age was 28.7 years, mean parity was 0.9, and mean body mass index was 23.6 kg/m(2). Infertility was seen in all 50 women (66% primary infertility, 34% secondary infertility), with a mean duration of 6.06 years. Abnormal laparoscopic findings of FGTB included tubercles in the pelvic peritoneum, fallopian tube, and ovary in 27 women (54%) before ATT and in only 1 (2.04%) woman after ATT (p < .001). Caseous nodules and encysted ascites were seen in 4 women (8%) before ATT, and in no women after ATT (p < .001); however, there was no change from before ATT to after ATT in the rate of pelvic adhesions (42% vs 42.5%) and perihepatic adhesions (56% vs 58%). Laparoscopic findings in fallopian tubes included hydrosalpinx (32%), pyosalpinx (4%), beaded tubes (12%), nonvisualization of tube (20%), and tubal blockage on the right side (56%), left side (50%), and both sides (38%) before ATT. Hydrosalpinx, beaded tubes, and nonvisualized tube were seen in 33.4%, 4.1%, and 20.8% cases, respectively, after ATT; however, free spill increased to 52% on the right side and 50% on left side after ATT. ATT improves laparoscopic findings in FGTB with infertility. However, advanced fibrotic lesions (eg, pelvic and perihepatic adhesions, bilateral blocked tubes) do not improve with ATT. Copyright © 2016 AAGL. Published by Elsevier Inc. All rights reserved.
Electromagnetic navigation diagnostic bronchoscopy for small peripheral lung lesions.
Makris, D; Scherpereel, A; Leroy, S; Bouchindhomme, B; Faivre, J-B; Remy, J; Ramon, P; Marquette, C-H
2007-06-01
The present study prospectively evaluated the diagnostic yield and safety of electromagnetic navigation-guided bronchoscopy biopsy, for small peripheral lung lesions in patients where standard techniques were nondiagnostic. The study was conducted in a tertiary medical centre on 40 consecutive patients considered unsuitable for straightforward surgery or computed tomography (CT)-guided transthoracic needle aspiration biopsy, due to comorbidities. The lung lesion diameter was mean+/-sem 23.5+/-1.5 mm and the depth from the visceral-costal pleura was 14.9+/-2 mm. Navigation was facilitated by an electromagnetic tracking system which could detect a position sensor incorporated into a flexible catheter advanced through a bronchoscope. Information obtained during bronchoscopy was superimposed on previously acquired CT data. Divergence between CT data and data obtained during bronchoscopy was calculated by the system's software as a measure of navigational accuracy. All but one of the target lesions was reached and the overall diagnostic yield was 62.5% (25-40). Diagnostic yield was significantly affected by CT-to-body divergence; yield was 77.2% when estimated divergence was
The capability of fluoroscopic systems to determine differential Roentgen-ray absorption
NASA Technical Reports Server (NTRS)
Baily, N. A.; Crepeau, R. L.
1975-01-01
A clinical fluoroscopic unit used in conjunction with a TV image digitization system was investigated to determine its capability to evaluate differential absorption between two areas in the same field. Fractional contrasts and minimum detectability for air, several concentrations of Renografin-60, and aluminum were studied using phantoms of various thicknesses. Results showed that the videometric response, when treated as contrast, shows a linear response with absorber thickness up to considerable thicknesses.
Sarkar, V; Gutierrez, A N; Stathakis, S; Swanson, G P; Papanikolaou, N
2009-01-01
The purpose of this project was to develop a software platform to produce a virtual fluoroscopic image as an aid for permanent prostate seed implants. Seed location information from a pre-plan was extracted and used as input to in-house developed software to produce a virtual fluoroscopic image. In order to account for differences in patient positioning on the day of treatment, the user was given the ability to make changes to the virtual image. The system has been shown to work as expected for all test cases. The system allows for quick (on average less than 10 sec) generation of a virtual fluoroscopic image of the planned seed pattern. The image can be used as a verification tool to aid the physician in evaluating how close the implant is to the planned distribution throughout the procedure and enable remedial action should a large deviation be observed.
Potential Biomarkers for Bevacizumab-Induced High Blood Pressure in Patients With Solid Tumor
2012-02-23
Breast Cancer; Cardiovascular Complications; Colorectal Cancer; Fallopian Tube Cancer; Head and Neck Cancer; Lung Cancer; Ovarian Cancer; Peritoneal Cavity Cancer; Unspecified Adult Solid Tumor, Protocol Specific
de Freitas, Ricardo Miguel Costa; Andrade, Celi Santos; Caldas, José Guilherme Mendes Pereira; Tsunemi, Miriam Harumi; Ferreira, Lorraine Braga; Arana-Chavez, Victor Elias; Cury, Patrícia Maluf
2015-10-01
This study was designed to present the feasibility of an in vivo image-guided percutaneous cryoablation of the porcine vertebral body. The institutional animal care committee approved this study. Cone-beam computed tomography (CBCT)-guided vertebral cryoablations (n = 22) were performed in eight pigs with short, 2-min, single or double-freezing protocols. Protective measures to nerves included dioxide carbon (CO2) epidural injections and spinal canal temperature monitoring. Clinical, radiological, and pathological data with light (n = 20) or transmission electron (n = 2) microscopic analyses were evaluated after 6 days of clinical follow-up and euthanasia. CBCT/fluoroscopic-guided transpedicular vertebral body cryoprobe positioning and CO2 epidural injection were successful in all procedures. No major complications were observed in seven animals (87.5 %, n = 8). A minor complication was observed in one pig (12.5 %, n = 1). Logistic regression model analysis showed the cryoprobe-spinal canal (Cp-Sc) distance as the most efficient parameter to categorize spinal canal temperatures lower than 19 °C (p < 0.004), with a significant Pearson's correlation test (p < 0.041) between the Cp-Sc distance and the lowest spinal canal temperatures. Ablation zones encompassed pedicles and the posterior wall of the vertebral bodies with an inflammatory rim, although no inflammatory infiltrate was depicted in the surrounding neural structures at light microscopy. Ultrastructural analyses evidenced myelin sheath disruption in some large nerve fibers, although neurological deficits were not observed. CBCT-guided vertebral cryoablation of the porcine spine is feasible under a combination of a short freezing protocol and protective measures to the surrounding nerves. Ultrastructural analyses may be helpful assess the early modifications of the nerve fibers.
Devito, Dennis P; Kaplan, Leon; Dietl, Rupert; Pfeiffer, Michael; Horne, Dale; Silberstein, Boris; Hardenbrook, Mitchell; Kiriyanthan, George; Barzilay, Yair; Bruskin, Alexander; Sackerer, Dieter; Alexandrovsky, Vitali; Stüer, Carsten; Burger, Ralf; Maeurer, Johannes; Donald, Gordon D; Gordon, Donald G; Schoenmayr, Robert; Friedlander, Alon; Knoller, Nachshon; Schmieder, Kirsten; Pechlivanis, Ioannis; Kim, In-Se; Meyer, Bernhard; Shoham, Moshe
2010-11-15
Retrospective, multicenter study of robotically-guided spinal implant insertions. Clinical acceptance of the implants was assessed by intraoperative radiograph, and when available, postoperative computed tomography (CT) scans were used to determine placement accuracy. To verify the clinical acceptance and accuracy of robotically-guided spinal implants and compare to those of unguided free-hand procedures. SpineAssist surgical robot has been used to guide implants and guide-wires to predefined locations in the spine. SpineAssist which, to the best of the authors' knowledge, is currently the sole robot providing surgical assistance in positioning tools in the spine, guided over 840 cases in 14 hospitals, between June 2005 and June 2009. Clinical acceptance of 3271 pedicle screws and guide-wires inserted in 635 reported cases was assessed by intraoperative fluoroscopy, where placement accuracy of 646 pedicle screws inserted in 139 patients was measured using postoperative CT scans. Screw placements were found to be clinically acceptable in 98% of the cases when intraoperatively assessed by fluoroscopic images. Measurements derived from postoperative CT scans demonstrated that 98.3% of the screws fell within the safe zone, where 89.3% were completely within the pedicle and 9% breached the pedicle by up to 2 mm. The remaining 1.4% of the screws breached between 2 and 4 mm, while only 2 screws (0.3%) deviated by more than 4 mm from the pedicle wall. Neurologic deficits were observed in 4 cases yet, following revisions, no permanent nerve damage was encountered, in contrast to the 0.6% to 5% of neurologic damage reported in the literature. SpineAssist offers enhanced performance in spinal surgery when compared to free-hand surgeries, by increasing placement accuracy and reducing neurologic risks. In addition, 49% of the cases reported herein used a percutaneous approach, highlighting the contribution of SpineAssist in procedures without anatomic landmarks.
Tubal telocytes: factor infertility reason?
Aleksandrovych, Veronika; Sajewicz, Marek; Walocha, Jerzy A; Gil, Krzysztof
Infertility is actually widespread pathological condition, which affected one in every four couples in developing countries. Approximately one third of all cases are connected with tubal factor infertility, o en accompanies by endometriosis, acute salpingitis, urogenital infections etc. The newly identified telocytes (TCs) have multiple potential bio-functions and might participate in the fertility problems. They influence on structural and functional integrity of oviduct tissue. Despite recent discovery, TCs involvement in the majority of physiological and pathological processes is still unclear and require significant increasing of deep observations and data analysis. Focusing on female reproductive system help better understands the main reasons of infertility, while evaluation of TCs impact on Fallopian tube and uterus contractility might be a key point of its correction. The article summarizes the main features of telocytes in Fallopian tubes, emphasizing their involvement in pathophysiological processes and tubal factor infertility.
Schuurman, Teska; Veersema, Sebastiaan
2011-01-01
This case report describes a successful hysteroscopic sterilisation using the Essure Permanent Birth Control device (Conceptus Inc., Mountain View, California, United States) after a failed procedure of the Adiana Permanent Contraception system (Hologic, Inc., Bedford, Maryland, United States). The delivery catheter of the Adiana system was able to be inserted into the left fallopian tube without difficulty and per manufacturer specifications. However, the position detection array was unable to sense four-quadrant tissue contact. The same issue occurred at the contralateral tube. Using the Essure system, the coils were able to be placed in both ostia easily and adequately. In patients in whom the Adiana system fails to occlude the fallopian tubes due to procedural, anatomic or device-related factors, the Essure procedure may be an efficient alternative. PMID:22689274
The fallopian tube-peritoneal junction: a potential site of carcinogenesis.
Seidman, Jeffrey D; Yemelyanova, Anna; Zaino, Richard J; Kurman, Robert J
2011-01-01
Junctions between different types of epithelia are hot spots for carcinogenesis, but the junction of the peritoneal mesothelium with the fallopian tubal epithelium, the tubal-peritoneal junction, has not been characterized earlier. A total of 613 junctional foci in 228 fallopian tube specimens from 182 patients who underwent surgery for a variety of indications, including 27 risk-reducing salpingo-oophorectomy specimens, were studied. Edema, congestion, and dilated lymphatic channels were commonly present. Transitional metaplasia was found at the junction in 20% of patients and mesothelial hyperplasia in 17%. Inflammation at the junction was seen predominantly in patients with salpingitis, torsion, or tubal pregnancy. Ovarian-type stroma was found at the junction in 5% of patients, and was found elsewhere in the tubal lamina propria in an additional 27% of patients. Findings in risk-reducing salpingo-oophorectomy specimens in women with BRCA mutations, a personal history of breast cancer, and/or a family history of breast/ovarian cancer were similar to those in controls. Transitional metaplasia specifically localizes to this junction, and is the probable source of Walthard cell nests. The recently highlighted significance of fimbrial tubal epithelium in the origin of serous ovarian carcinomas and a study suggesting that mucinous and Brenner tumors may arise from transitional-type epithelium in this location suggest that the tubal-peritoneal junction may play a role in the development of these tumors. This is the first comprehensive description of a hitherto unrecognized transitional zone in the adnexa.
Congenital or torsion-induced absence of Fallopian tubes. Two case reports.
Paternoster, D M; Costantini, W; Uglietti, A; Vasile, C; Bocconi, L
1998-05-01
Unilateral absence of a uterine tube is an extremely rare finding, for which there are two possible etiopathogenic causes: in some cases it is due to haemorrhage filling of the cavity and its reabsorption as a result of asymptomatic torsion of the uterine tube during adult life, in pediatric age or even during intrauterine life; alternatively, the absence may be congenital, associated with developmental alterations of the mesonephric and paramesonephric ducts. The article presents two cases of fallopian tube absence: a congenital monolateral absence and a tubal torsion during pregnancy. The symptomatology of the torsion of the fallopian tube in pregnancy can be milder than in the classic description with peritoneal reaction and severe clinical alteration. The main risk factors for tubal torsion are: adhesions and inflammatory processes, ovarian cysts, usually of dermoid type, menstrual period, pregnancy, abnormal long mesosalpinx and/or mesovarium, pelvic congestion induced by constipation and disturbed venous blood flow from the adnexa. A congenital defect of the mesonephric duct is followed by a homolateral defect of the paramesonephric duct. The resulting anomaly is characterized by the absence of the uterine tube, uterus-tube angle, kidney and ureter. Partial or total unilateral defects of a paramesonephric duct are more common than aplasia of both ducts. Some authors have suggested that an inadequate blood supply during the descent into the pelvis of the caudal part of the paramesonephric duct might feasibly lead to incomplete tube development.
Cells of origin of ovarian cancer: ovarian surface epithelium or fallopian tube?
Klotz, Daniel Martin; Wimberger, Pauline
2017-12-01
Ovarian cancer is the fifth most common cancer in women and one of the leading causes of death from gynecological malignancies. Despite of its clinical importance, ovarian tumorigenesis is poorly understood and prognosis remains poor. This is particularly true for the most common type of ovarian cancer, high-grade serous ovarian cancer. Two models are considered, whether it arises from the ovarian surface epithelium or from the fallopian tube. The first model is based on (1) the pro-inflammatory environment caused by ovulation events, (2) the expression pattern of ovarian inclusion cysts, and (3) biomarkers that are shared by the ovarian surface epithelium and malignant growth. The model suggesting a non-ovarian origin is based on (1) tubal precursor lesions, (2) genetic evidence of BRCA1/2 mutation carriers, and (3) recent animal studies. Neither model has clearly demonstrated superiority over the other. Therefore, one can speculate that high-grade serous ovarian cancer may arise from two different sites that undergo similar changes. Both tissues are derived from the same embryologic origin, which may explain how progenitor cells from different sites can respond similar to stimuli within the ovaries. However, distinct molecular drivers, such as BRCA deficiency, may still preferentially arise from one site of origin as precancerous mutations are frequently seen in the fallopian tube. Confirming the origin of ovarian cancer has important clinical implications when deciding on cancer risk-reducing prophylactic surgery. It will be important to identify key biomarker to uncover the sequence of ovarian tumorigenesis.
Kim, Min-Su; Kim, Go-Woon; Rho, Young-Soo; Kwon, Kee-Hwan; Chung, Eun-Jae
2017-05-01
This retrospective study was carried out to investigate the effectiveness and safety of office-based electromyography-guided injection of botulinum toxin in the cricopharyngeus muscle of patients who did not show upper esophageal sphincter passage in a swallowing study in spite of maximal swallowing rehabilitation. Thirty-six patients who showed no or limited ability to oral feed after maximum swallowing rehabilitation were enrolled. Video fluoroscopic swallowing study, flexible endoscopic evaluation of swallowing, disability rating scale, penetration aspiration score, and National Institutes of Health swallowing safety scale were used in the evaluation of dysphagia. Success was defined as nondependence on gastrostomy for patients who previously were dependent on gastrostomy and improvement in disability rating scale score after botulinum toxin injections. The total success rate was 63.9%. The complication rate was very low, with only 1 patient showing temporary unilateral vocal fold paralysis. Botulinum toxin injection was more effective in patients with cranial nerve IX or X palsy than in those without it ( P = .006). This procedure can be a simple, safe, and effective tool in patients with cricopharyngeal dysfunction after swallowing rehabilitation, especially for cranial nerve IX or X palsy.
Percutaneous Image-Guided Aspiration and Sclerosis of Adventitial Cystic Disease of the Femoral Vein
DOE Office of Scientific and Technical Information (OSTI.GOV)
Johnson, Jason M.; Kiankhooy, Armin; Bertges, Daniel J.
2009-07-15
Adventitial cystic disease (ACD), also known as cystic mucoid or myxomatous degeneration, is a rare vascular disease mainly seen in arteries. Seventeen cases have been reported in the world literature. We report the first known case of ACD successfully treated with percutaneous image-guided ethanol sclerosis. Computed tomography showed a cystic mass adherent to the wall of the common femoral vein. An ultrasound examination revealed a deep venous thrombosis of the leg, secondary to extrinsic compression of the common femoral vein. Three years prior to our procedure, the cyst was aspirated, which partially relieved the patient's symptoms. Over the following 3more » years the patient's symptoms worsened and a 10-cm discrepancy in thigh size developed, in addition to the deep venous thrombosis associated with lower-extremity edema. Using ultrasound guidance and fluoroscopic control, the cyst was drained and then sclerosed with absolute ethanol. The patient's symptoms and leg swelling resolved completely within several weeks. Follow-up physical examination and duplex ultrasound 6 months following sclerosis demonstrated resolution of the symptoms and elimination of the extrinsic compression effect of the ACD on the common femoral vein.« less
Multiple template-based fluoroscopic tracking of lung tumor mass without implanted fiducial markers
NASA Astrophysics Data System (ADS)
Cui, Ying; Dy, Jennifer G.; Sharp, Gregory C.; Alexander, Brian; Jiang, Steve B.
2007-10-01
Precise lung tumor localization in real time is particularly important for some motion management techniques, such as respiratory gating or beam tracking with a dynamic multi-leaf collimator, due to the reduced clinical tumor volume (CTV) to planning target volume (PTV) margin and/or the escalated dose. There might be large uncertainties in deriving tumor position from external respiratory surrogates. While tracking implanted fiducial markers has sufficient accuracy, this procedure may not be widely accepted due to the risk of pneumothorax. Previously, we have developed a technique to generate gating signals from fluoroscopic images without implanted fiducial markers using a template matching method (Berbeco et al 2005 Phys. Med. Biol. 50 4481-90, Cui et al 2007 Phys. Med. Biol. 52 741-55). In this paper, we present an extension of this method to multiple-template matching for directly tracking the lung tumor mass in fluoroscopy video. The basic idea is as follows: (i) during the patient setup session, a pair of orthogonal fluoroscopic image sequences are taken and processed off-line to generate a set of reference templates that correspond to different breathing phases and tumor positions; (ii) during treatment delivery, fluoroscopic images are continuously acquired and processed; (iii) the similarity between each reference template and the processed incoming image is calculated; (iv) the tumor position in the incoming image is then estimated by combining the tumor centroid coordinates in reference templates with proper weights based on the measured similarities. With different handling of image processing and similarity calculation, two such multiple-template tracking techniques have been developed: one based on motion-enhanced templates and Pearson's correlation score while the other based on eigen templates and mean-squared error. The developed techniques have been tested on six sequences of fluoroscopic images from six lung cancer patients against the reference tumor positions manually determined by a radiation oncologist. The tumor centroid coordinates automatically detected using both methods agree well with the manually marked reference locations. The eigenspace tracking method performs slightly better than the motion-enhanced method, with average localization errors less than 2 pixels (1 mm) and the error at a 95% confidence level of about 2-4 pixels (1-2 mm). This work demonstrates the feasibility of direct tracking of a lung tumor mass in fluoroscopic images without implanted fiducial markers using multiple reference templates.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dhou, S; Cai, W; Hurwitz, M
2015-06-15
Purpose: Respiratory-correlated cone-beam CT (4DCBCT) images acquired immediately prior to treatment have the potential to represent patient motion patterns and anatomy during treatment, including both intra- and inter-fractional changes. We develop a method to generate patient-specific motion models based on 4DCBCT images acquired with existing clinical equipment and used to generate time varying volumetric images (3D fluoroscopic images) representing motion during treatment delivery. Methods: Motion models are derived by deformably registering each 4DCBCT phase to a reference phase, and performing principal component analysis (PCA) on the resulting displacement vector fields. 3D fluoroscopic images are estimated by optimizing the resulting PCAmore » coefficients iteratively through comparison of the cone-beam projections simulating kV treatment imaging and digitally reconstructed radiographs generated from the motion model. Patient and physical phantom datasets are used to evaluate the method in terms of tumor localization error compared to manually defined ground truth positions. Results: 4DCBCT-based motion models were derived and used to generate 3D fluoroscopic images at treatment time. For the patient datasets, the average tumor localization error and the 95th percentile were 1.57 and 3.13 respectively in subsets of four patient datasets. For the physical phantom datasets, the average tumor localization error and the 95th percentile were 1.14 and 2.78 respectively in two datasets. 4DCBCT motion models are shown to perform well in the context of generating 3D fluoroscopic images due to their ability to reproduce anatomical changes at treatment time. Conclusion: This study showed the feasibility of deriving 4DCBCT-based motion models and using them to generate 3D fluoroscopic images at treatment time in real clinical settings. 4DCBCT-based motion models were found to account for the 3D non-rigid motion of the patient anatomy during treatment and have the potential to localize tumor and other patient anatomical structures at treatment time even when inter-fractional changes occur. This project was supported, in part, through a Master Research Agreement with Varian Medical Systems, Inc., Palo Alto, CA. The project was also supported, in part, by Award Number R21CA156068 from the National Cancer Institute.« less
Intraoperative panoramic image using alignment grid, is it accurate?
Apivatthakakul, T; Duanghakrung, M; Luevitoonvechkit, S; Patumasutra, S
2013-07-01
Minimally invasive orthopedic trauma surgery relies heavily on intraoperative fluoroscopic images to evaluate the quality of fracture reduction and fixation. However, fluoroscopic images have a narrow field of view and often cannot visualize the entire long bone axis. To compare the coronal femoral alignment between conventional X-rays to that achieved with a new method of acquiring a panoramic intraoperative image. Twenty-four cadaveric femurs with simple diaphyseal fractures were fixed with an angulated broad DCP to create coronal plane malalignment. An intraoperative alignment grid was used to help stitch different fluoroscopic images together to produce a panoramic image. A conventional X-ray of the entire femur was then performed. The coronal plane angulation in the panoramic images was then compared to the conventional X-rays using a Wilcoxon signed rank test. The mean angle measured from the panoramic view was 173.9° (range 169.3°-178.0°) with median of 173.2°. The mean angle measured from the conventional X-ray was 173.4° (range 167.7°-178.7°) with a median angle of 173.5°. There was no significant difference between both methods of measurement (P = 0.48). Panoramic images produced by stitching fluoroscopic images together with help of an alignment grid demonstrated the same accuracy at evaluating the coronal plane alignment of femur fractures as conventional X-rays.
ANGIOGRAPHIC ANATOMY OF THE MAJOR ABDOMINAL ARTERIAL BLOOD SUPPLY IN THE DOG.
Culp, William T N; Mayhew, Philipp D; Pascoe, Peter J; Zwingenberger, Allison
2015-01-01
Vascular-based interventional radiology (IR) procedures are being more regularly performed in veterinary patients for both diagnostic and therapeutic purposes. A complete description of the fluoroscopic arterial anatomy of the canine abdominal cavity has not been published. This information is essential for performance of IR procedures to allow for improved preparation before and during a particular procedure. The primary purpose of this study was to provide a fluoroscopic description of the vascular branching from the abdominal aorta in a ventro-dorsal projection with a secondary goal of producing pictorial reference images of the major abdominal arterial blood vessels. Five healthy female hound type dogs were enrolled and underwent fluoroscopic arteriography. During fluoroscopy, both nonselective and selective arteriography were performed. The nonselective arteriograms were obtained in the aorta at four locations: cranial to the celiac artery, cranial to the renal arteries, cranial to the caudal mesenteric artery, and cranial to the branching of the external iliac arteries. Selective arteriography was conducted by performing injections into the following arteries: celiac, splenic, common hepatic, cranial mesenteric, left and right renal, and caudal mesenteric. Fluoroscopic arteriography allowed for excellent characterization of the aortic ostia and the location of the lower order vascular branches. Future evaluation of vascular-based treatment options will likely increase as the understanding of the normal and pathologic anatomy improves. © 2015 American College of Veterinary Radiology.
Fluoroscopic and radiographic evaluation of tracheal collapse in dogs: 62 cases (2001-2006).
Macready, Dawn M; Johnson, Lynelle R; Pollard, Rachel E
2007-06-15
To compare the use of radiography and fluoroscopy for detection and grading of tracheal collapse in dogs. Retrospective case series. Animals-62 dogs with tracheal collapse. For each dog, tracheal collapse was confirmed fluoroscopically and lateral cervical and thoracic radiographic views were reviewed. A board-certified radiologist (who was unaware of the dogs' clinical history) evaluated the cervical, thoracic inlet, thoracic, carinal, and main stem bronchial regions in all fluoroscopic videos and radiographic images for evidence of collapse. Cervical, thoracic inlet, thoracic, and carinal regions in both radio-graphic and fluoroscopic studies were graded for collapse (0%, 25%, 50%, 75%, or 100% decrease in diameter). Lateral cervical and thoracic radiographic images were available for 54 dogs, and inspiratory and expiratory lateral cervical and thoracic radiographic images were available for 8 dogs. For detection of tracheal collapse, assessment of radiographic views was sensitive and had the best negative predictive value in the cervical and thoracic inlet regions. Assessment of radiographic views was most specific and had the best positive predictive value in the thoracic inlet, thoracic, carina, and main stem bronchial regions. Radiography underestimated the degree of collapse in all areas. Review of inspiratory and expiratory views improved the accuracy of radiography for tracheal collapse diagnosis only slightly. Compared with fluoroscopy, radiography underestimated the frequency and degree of tracheal collapse. However, radiography appears to be useful for screening dogs with potential tracheal collapse.
MacVicar, John; Kreiner, D Scott; Duszynski, Belinda; Kennedy, David J
2017-11-01
To provide an overview of a multisociety effort to formulate appropriate use criteria for image-guided injections and radiofrequency procedures in the diagnosis and treatment of sacroiliac joint and posterior sacroiliac complex pain. The Spine Intervention Society convened a multisociety effort to guide physicians and define for payers the appropriate use of image-guided injections and radiofrequency procedures. An evidence panel was established to write systematic reviews, define key terms and assumptions, and develop clinical scenarios to be addressed. The rating panel considered the evidence presented in the systematic reviews, carefully reviewed the definitions and assumptions, and rated the clinical scenarios. Final median ratings, in combination with the level of agreement, determined the final ratings for the appropriate use of sacroiliac injections and radiofrequency neurotomy. More than 10,000 scenarios were addressed in the appropriate use criteria and are housed within five modules in the portal, available on the Spine Intervention Society website: Module 1: Clinical Indications and Imaging; Module 2: Anticoagulants; Module 3: Timing of Injections; Module 4: Number of Injections; and Module 5: Lateral Branch Radiofrequency Neurotomy. Within several of these modules, several issues of interest are identified and discussed. Physicians and payers can access the appropriate use criteria portal on the Spine Intervention Society's website and select specific clinical indications for a particular patient in order to learn more about the appropriateness of the intervention(s) under consideration. © 2017 American Academy of Pain Medicine. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com
Gibby, Jacob T; Swenson, Samuel A; Cvetko, Steve; Rao, Raj; Javan, Ramin
2018-06-22
Augmented reality has potential to enhance surgical navigation and visualization. We determined whether head-mounted display augmented reality (HMD-AR) with superimposed computed tomography (CT) data could allow the wearer to percutaneously guide pedicle screw placement in an opaque lumbar model with no real-time fluoroscopic guidance. CT imaging was obtained of a phantom composed of L1-L3 Sawbones vertebrae in opaque silicone. Preprocedural planning was performed by creating virtual trajectories of appropriate angle and depth for ideal approach into the pedicle, and these data were integrated into the Microsoft HoloLens using the Novarad OpenSight application allowing the user to view the virtual trajectory guides and CT images superimposed on the phantom in two and three dimensions. Spinal needles were inserted following the virtual trajectories to the point of contact with bone. Repeat CT revealed actual needle trajectory, allowing comparison with the ideal preprocedural paths. Registration of AR to phantom showed a roughly circular deviation with maximum average radius of 2.5 mm. Users took an average of 200 s to place a needle. Extrapolation of needle trajectory into the pedicle showed that of 36 needles placed, 35 (97%) would have remained within the pedicles. Needles placed approximated a mean distance of 4.69 mm in the mediolateral direction and 4.48 mm in the craniocaudal direction from pedicle bone edge. To our knowledge, this is the first peer-reviewed report and evaluation of HMD-AR with superimposed 3D guidance utilizing CT for spinal pedicle guide placement for the purpose of cannulation without the use of fluoroscopy.
2018-01-16
Colorectal Cancer (CRC); Ovarian Cancer (Epithelial and Fallopian Tube ); Urothelial Carcinoma; Triple-negative Breast Cancer (TNBC); Pancreatic Cancer; Acute Myeloid Leukemia/Myelodysplastic Syndrome; Multiple Myeloma (MM)
Dagnino, Giulio; Georgilas, Ioannis; Morad, Samir; Gibbons, Peter; Tarassoli, Payam; Atkins, Roger; Dogramadzi, Sanja
2017-08-01
Joint fractures must be accurately reduced minimising soft tissue damages to avoid negative surgical outcomes. To this regard, we have developed the RAFS surgical system, which allows the percutaneous reduction of intra-articular fractures and provides intra-operative real-time 3D image guidance to the surgeon. Earlier experiments showed the effectiveness of the RAFS system on phantoms, but also key issues which precluded its use in a clinical application. This work proposes a redesign of the RAFS's navigation system overcoming the earlier version's issues, aiming to move the RAFS system into a surgical environment. The navigation system is improved through an image registration framework allowing the intra-operative registration between pre-operative CT images and intra-operative fluoroscopic images of a fractured bone using a custom-made fiducial marker. The objective of the registration is to estimate the relative pose between a bone fragment and an orthopaedic manipulation pin inserted into it intra-operatively. The actual pose of the bone fragment can be updated in real time using an optical tracker, enabling the image guidance. Experiments on phantom and cadavers demonstrated the accuracy and reliability of the registration framework, showing a reduction accuracy (sTRE) of about [Formula: see text] (phantom) and [Formula: see text] (cadavers). Four distal femur fractures were successfully reduced in cadaveric specimens using the improved navigation system and the RAFS system following the new clinical workflow (reduction error [Formula: see text], [Formula: see text]. Experiments showed the feasibility of the image registration framework. It was successfully integrated into the navigation system, allowing the use of the RAFS system in a realistic surgical application.
NASA Astrophysics Data System (ADS)
Shankar, A.; Russ, M.; Vijayan, S.; Bednarek, D. R.; Rudin, S.
2017-03-01
Apodized Aperture Pixel (AAP) design, proposed by Ismailova et.al, is an alternative to the conventional pixel design. The advantages of AAP processing with a sinc filter in comparison with using other filters include non-degradation of MTF values and elimination of signal and noise aliasing, resulting in an increased performance at higher frequencies, approaching the Nyquist frequency. If high resolution small field-of-view (FOV) detectors with small pixels used during critical stages of Endovascular Image Guided Interventions (EIGIs) could also be extended to cover a full field-of-view typical of flat panel detectors (FPDs) and made to have larger effective pixels, then methods must be used to preserve the MTF over the frequency range up to the Nyquist frequency of the FPD while minimizing aliasing. In this work, we convolve the experimentally measured MTFs of an Microangiographic Fluoroscope (MAF) detector, (the MAF-CCD with 35μm pixels) and a High Resolution Fluoroscope (HRF) detector (HRF-CMOS50 with 49.5μm pixels) with the AAP filter and show the superiority of the results compared to MTFs resulting from moving average pixel binning and to the MTF of a standard FPD. The effect of using AAP is also shown in the spatial domain, when used to image an infinitely small point object. For detectors in neurovascular interventions, where high resolution is the priority during critical parts of the intervention, but full FOV with larger pixels are needed during less critical parts, AAP design provides an alternative to simple pixel binning while effectively eliminating signal and noise aliasing yet allowing the small FOV high resolution imaging to be maintained during critical parts of the EIGI.
[Navigated drilling for femoral head necrosis. Experimental and clinical results].
Beckmann, J; Tingart, M; Perlick, L; Lüring, C; Grifka, J; Anders, S
2007-05-01
In the early stages of osteonecrosis of the femoral head, core decompression by exact drilling into the ischemic areas can reduce pain and achieve reperfusion. Using computer aided surgery, the precision of the drilling can be improved while simultaneously lowering radiation exposure time for both staff and patients. We describe the experimental and clinical results of drilling under the guidance of the fluoroscopically-based VectorVision navigation system (BrainLAB, Munich, Germany). A total of 70 sawbones were prepared mimicking an osteonecrosis of the femoral head. In two experimental models, bone only and obesity, as well as in a clinical setting involving ten patients with osteonecrosis of the femoral head, the precision and the duration of radiation exposure were compared between the VectorVision system and conventional drilling. No target was missed. For both models, there was a statistically significant difference in terms of the precision, the number of drilling corrections as well as the radiation exposure time. The average distance to the desired midpoint of the lesion of both models was 0.48 mm for navigated drilling and 1.06 mm for conventional drilling, the average drilling corrections were 0.175 and 2.1, and the radiation exposure time less than 1 s and 3.6 s, respectively. In the clinical setting, the reduction of radiation exposure (below 1 s for navigation compared to 56 s for the conventional technique) as well as of drilling corrections (0.2 compared to 3.4) was also significant. Computer guided drilling using the fluoroscopically based VectorVision navigation system shows a clearly improved precision with a enormous simultaneous reduction in radiation exposure. It is therefore recommended for clinical routine.
Precision of computer-assisted core decompression drilling of the femoral head.
Beckmann, J; Goetz, J; Baethis, H; Kalteis, T; Grifka, J; Perlick, L
2006-08-01
Osteonecrosis of the femoral head is a local destructive disease with progression into devastating stages. Left untreated it mostly leads to severe secondary osteoarthrosis and early endoprosthetic joint replacement. Core decompression by exact drilling into the ischemic areas can be performed in early stages according to Ficat or ARCO. Computer-aided surgery might enhance the precision of the drilling and lower the radiation exposure time of both staff and patients. The aim of this study was to evaluate the precision of the fluoroscopically based VectorVision navigation system in an in vitro model. Thirty sawbones were prepared with a defect filled up with a radiopaque gypsum sphere mimicking the osteonecrosis. Twenty sawbones were drilled by guidance of an intraoperative navigation system VectorVision (BrainLAB, Munich, Germany) and 10 sawbones by fluoroscopic control only. No gypsum sphere was missed. There was a statistically significant difference regarding the three-dimensional deviation (Euclidian norm) as well as maximum deviation in x-, y- or z-direction (maximum norm) to the desired mid-point of the lesion, with a mean of 0.51 and 0.4 mm in the navigated group and 1.1 and 0.88 mm in the control group, respectively. Furthermore, significant difference was found in the number of drilling corrections as well as the radiation time needed: no second drilling or correction of drilling direction was necessary in the navigated group compared to 1.4 in the control group. The radiation time needed was less than 1 s compared to 3.1 s, respectively. The fluoroscopy-based VectorVision navigation system shows a high feasibility of computer-guided drilling with a clear reduction of radiation exposure time and can therefore be integrated into clinical routine. The additional time needed is acceptable regarding the simultaneous reduction of radiation time.
Theoretical performance analysis for CMOS based high resolution detectors.
Jain, Amit; Bednarek, Daniel R; Rudin, Stephen
2013-03-06
High resolution imaging capabilities are essential for accurately guiding successful endovascular interventional procedures. Present x-ray imaging detectors are not always adequate due to their inherent limitations. The newly-developed high-resolution micro-angiographic fluoroscope (MAF-CCD) detector has demonstrated excellent clinical image quality; however, further improvement in performance and physical design may be possible using CMOS sensors. We have thus calculated the theoretical performance of two proposed CMOS detectors which may be used as a successor to the MAF. The proposed detectors have a 300 μm thick HL-type CsI phosphor, a 50 μm-pixel CMOS sensor with and without a variable gain light image intensifier (LII), and are designated MAF-CMOS-LII and MAF-CMOS, respectively. For the performance evaluation, linear cascade modeling was used. The detector imaging chains were divided into individual stages characterized by one of the basic processes (quantum gain, binomial selection, stochastic and deterministic blurring, additive noise). Ranges of readout noise and exposure were used to calculate the detectors' MTF and DQE. The MAF-CMOS showed slightly better MTF than the MAF-CMOS-LII, but the MAF-CMOS-LII showed far better DQE, especially for lower exposures. The proposed detectors can have improved MTF and DQE compared with the present high resolution MAF detector. The performance of the MAF-CMOS is excellent for the angiography exposure range; however it is limited at fluoroscopic levels due to additive instrumentation noise. The MAF-CMOS-LII, having the advantage of the variable LII gain, can overcome the noise limitation and hence may perform exceptionally for the full range of required exposures; however, it is more complex and hence more expensive.
Wu, Y; Li, K-L; Zheng, J; Zhang, C-Y; Liu, X-Y; Cui, Z-M; Yu, Z-M; Wang, R-X; Wang, W
2015-09-01
The purpose of this study was to prospectively evaluate the efficacy and safety of remote magnetic navigation (RMN) in comparison with manual catheter navigation (MCN) in performing ventricular tachycardia ablation. An electronic search was performed using PubMed (1948-2013) and EMBASE (1974-2013) studies comparing RMN with MCN which were published prior to 31 December 2013. Outcomes of interest were as follows: acute success, recurrence rate, complications, total procedure and fluoroscopic times. Standard mean difference (SMD) and its 95 % confidence interval (CI) were used for continuous outcomes; odds ratios (OR) were reported for dichotomous variables. Four non-randomised studies, including a total of 328 patients, were identified. RMN was deployed in 191 patients. Acute success and long-term freedom from arrhythmias were not significantly different between the RMN and control groups (OR 1.845, 95 % CI 0.731-4.659, p = 0.195 and OR 0.676, 95 % CI 0.383-1.194, p = 0.177, respectively). RMN was associated with less peri-procedural complications (OR 0.279, 95 % CI 0.092-0.843, p = 0.024). Shorter procedural and fluoroscopy times were achieved (95 % CI -0.487 to -0.035, p = 0.024 and 95 % CI -1.467 to -0.984, p<0.001, respectively). The acute and long-term success rates for VT ablation are equal between RMN and MCN, whereas the RMN-guided procedure can be performed with a lower complication rate and less procedural and fluoroscopic times. More prospective randomised trials will be needed to better evaluate the superior role of RMN for catheter ablation of ventricular tachycardia.
Keleshis, C; Ionita, CN; Yadava, G; Patel, V; Bednarek, DR; Hoffmann, KR; Verevkin, A; Rudin, S
2008-01-01
A graphical user interface based on LabVIEW software was developed to enable clinical evaluation of a new High-Sensitivity Micro-Angio-Fluoroscopic (HSMAF) system for real-time acquisition, display and rapid frame transfer of high-resolution region-of-interest images. The HSMAF detector consists of a CsI(Tl) phosphor, a light image intensifier (LII), and a fiber-optic taper coupled to a progressive scan, frame-transfer, charged-coupled device (CCD) camera which provides real-time 12 bit, 1k × 1k images capable of greater than 10 lp/mm resolution. Images can be captured in continuous or triggered mode, and the camera can be programmed by a computer using Camera Link serial communication. A graphical user interface was developed to control the camera modes such as gain and pixel binning as well as to acquire, store, display, and process the images. The program, written in LabVIEW, has the following capabilities: camera initialization, synchronized image acquisition with the x-ray pulses, roadmap and digital subtraction angiography acquisition (DSA), flat field correction, brightness and contrast control, last frame hold in fluoroscopy, looped playback of the acquired images in angiography, recursive temporal filtering and LII gain control. Frame rates can be up to 30 fps in full-resolution mode. The user friendly implementation of the interface along with the high framerate acquisition and display for this unique high-resolution detector should provide angiographers and interventionalists with a new capability for visualizing details of small vessels and endovascular devices such as stents and hence enable more accurate diagnoses and image guided interventions. (Support: NIH Grants R01NS43924, R01EB002873) PMID:18836570
Keleshis, C; Ionita, Cn; Yadava, G; Patel, V; Bednarek, Dr; Hoffmann, Kr; Verevkin, A; Rudin, S
2008-01-01
A graphical user interface based on LabVIEW software was developed to enable clinical evaluation of a new High-Sensitivity Micro-Angio-Fluoroscopic (HSMAF) system for real-time acquisition, display and rapid frame transfer of high-resolution region-of-interest images. The HSMAF detector consists of a CsI(Tl) phosphor, a light image intensifier (LII), and a fiber-optic taper coupled to a progressive scan, frame-transfer, charged-coupled device (CCD) camera which provides real-time 12 bit, 1k × 1k images capable of greater than 10 lp/mm resolution. Images can be captured in continuous or triggered mode, and the camera can be programmed by a computer using Camera Link serial communication. A graphical user interface was developed to control the camera modes such as gain and pixel binning as well as to acquire, store, display, and process the images. The program, written in LabVIEW, has the following capabilities: camera initialization, synchronized image acquisition with the x-ray pulses, roadmap and digital subtraction angiography acquisition (DSA), flat field correction, brightness and contrast control, last frame hold in fluoroscopy, looped playback of the acquired images in angiography, recursive temporal filtering and LII gain control. Frame rates can be up to 30 fps in full-resolution mode. The user friendly implementation of the interface along with the high framerate acquisition and display for this unique high-resolution detector should provide angiographers and interventionalists with a new capability for visualizing details of small vessels and endovascular devices such as stents and hence enable more accurate diagnoses and image guided interventions. (Support: NIH Grants R01NS43924, R01EB002873).
NASA Astrophysics Data System (ADS)
Hoopes, P. J.; Eskey, Cliff J.; Attawia, Mohammed; Patel, Samit J.; Ryan, T. P.; Pellegrino, Richard; Bergeron, Jeffrey A.
2005-04-01
Pathological involvement of the basivertebral nerve (BVN), an intraosseous vertebral nerve, may play a significant role in some forms of back pain. This study was designed to assess the feasibility and effects of thermal ablation of the lumbar basivertebral nerve in mature sheep. Sixteen adult female sheep weighing 65-80 kg were anesthetized and positioned for ventral recumbent surgery. Under fluoroscopic guidance, two bilarterally oposed 5mm active length rediofrequency (RF) electrodes (1.65mm diameter were perfutaneously placed in select lumbar vertebrae at a relative angle of 70 degrees with a 5 mm tip separation. The elctrodes were advanced to the region of the vertebral bodies which contained the BVN. A thermal dose of 95° C/720 seconds was administered. Animals were survived for 2, 14, 90, or 180 days post-treatment. Clinical, radiologic and pathologic investigations were performed to determine the effect of the heat on the BVN and associated tissues. Thermal damage to the basivertebral neurovascular bundle was characterized by early hemorrhage and necrosis, followed by inflammation and fibrosis. Although there wasa significant revascularization of the treated bone marow regions, there was no evidence of basivertebral nerve survival or regeneration regeneration. In addition to ablation of teh basivertebral nerovascular bundle, the areas receiving the greatest treatment demonstrated initial mild local osteolysis and demineralization of the vertebral body bone and regional depopulation of the vertebral bone marrow cellular elements. Significant bone remodeling in the affected areas had begun by 14 days post-treatment. Bone remodeling was characterized by conventional osteoblast proliferation, osteoid deposition, and mineralization. This study demonstrated the ability to accurately, reproducibly, and safely ablate the basivertebral nerve and neurovascular bundle in mature sheep using a fluoroscopically guided percutaneously delivered radiofrequency technique.
Occupational health hazards in the interventional laboratory: Time for a safer environment.
Klein, Lloyd W; Miller, Donald L; Balter, Stephen; Laskey, Warren; Naito, Neil; Haines, David; Ross, Allan; Mauro, Matthew A; Goldstein, James A
2018-01-04
Over the past 30 years, the advent of fluoroscopically guided interventional procedures has resulted in dramatic increments in both X-ray exposure and physical demands that predispose interventionists to distinct occupational health hazards. The hazards of accumulated radiation exposure have been known for years, but until recently the other potential risks have been ill-defined and under-appreciated. The physical stresses inherent in this career choice appear to be associated with a predilection to orthopedic injuries, attributable in great part to the cumulative adverse effects of bearing the weight and design of personal protective apparel worn to reduce radiation risk and to the poor ergonomic design of interventional suites. These occupational health concerns pertain to cardiologists, radiologists and surgeons working with fluoroscopy, pain management specialists performing nonvascular fluoroscopic procedures, and the many support personnel working in these environments. This position paper is the work of representatives of the major societies of physicians who work in the interventional laboratory environment, and has been formally endorsed by all. In this paper, the available data delineating the prevalence of these occupational health risks is reviewed and ongoing epidemiological studies designed to further elucidate these risks are summarized. The main purpose is to publicly state speaking with a single voice that the interventional laboratory poses workplace hazards that must be acknowledged, better understood and mitigated to the greatest extent possible, and to advocate vigorously on behalf of efforts to reduce these hazards. Interventional physicians and their professional societies, working together with industry, should strive toward the ultimate zero radiation exposure work environment that would eliminate the need for personal protective apparel and prevent its orthopedic and ergonomic consequences. © 2008 Wiley-Liss, Inc. Copyright © 2008 Wiley‐Liss, Inc.
Maduri, Rodolfo; Bobinski, Lukas; Duff, John Michael
2017-02-01
Standard translaminar approaches for intradural extramedullary (IDEM) tumors require extensive soft tissue dissection and partial facet removal. Ventral lesions may necessitate wider bone resection with subsequent possible spinal instability. Any manipulation of an already compromised spinal cord may lead to neurological injury. We describe an image-guided minimal access technique for IDEM tumor resection. Retrospective chart review of 13 consecutive patients after institutional ethics committee approval. We superimpose preoperative magnetic resonance imaging data with intraoperative 3-dimensional fluoroscopic images, allowing to simultaneously visualize osseous anatomy and the soft tissue lesion using appropriate windowing. We then plan optimal angle of trajectory to the tumor, which defines the skin incision and the transmuscular trajectory. A tubular retractor is placed to span the tumor. Microsurgical tumor resection is then carried out using this angle of approach. Thirteen patients (mean age. 57 years; male-to-female ratio, 10:3) were operated on during 28 months. Gross total resection was achieved in all patients. Neurological improvement occurred in 12 of the 13 patients. There was no neurological deficit outside of the expected sensory loss due to intentional nerve root sacrifice. No mechanical pain nor tumor recurrence were noted during the follow-up (mean, 16 months; range, 2-30 months). Image merge tailored access resection appears to be at least equivalent in terms of tumor resection, blood loss, and complications to other tubular techniques. It may reduce risks of neurological deficit and spine instability. Image merge tailored access resection is a novel application of merging intraoperative fluoroscopic images with preoperative magnetic resonance images for tailored IDEM resection. Copyright © 2016 Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Newell, J. D.; Keller, R. A.; Baily, N. A.
1974-01-01
A simple method for outlining or contouring any area defined by a change in film density or fluoroscopic screen intensity is described. The entire process, except for the positioning of an electronic window, is accomplished using a small computer having appropriate softwave. The electronic window is operator positioned over the area to be processed. The only requirement is that the window be large enough to encompass the total area to be considered.
Are all pelvic (nonuterine) serous carcinomas of tubal origin?
Przybycin, Christopher G; Kurman, Robert J; Ronnett, Brigitte M; Shih, Ie-Ming; Vang, Russell
2010-10-01
It has been proposed that the presence of tubal intraepithelial carcinoma (TIC), in association with one-third to nearly half of pelvic serous carcinomas, is evidence of fallopian tube origin for high-grade serous carcinomas that would have been otherwise classified as primary ovarian or peritoneal. To address this hypothesis, we evaluated a series of 114 consecutive pelvic (nonuterine) gynecologic carcinomas at our institution (2006 to 2008) to determine the frequency of TIC in 52 cases in which all the resected fallopian tube tissue was examined microscopically. These 52 cases were classified as ovarian (n=37), peritoneal (n=8), or fallopian tube (n=7) in origin as per conventional criteria based on disease distribution. The presence of TIC and its location and relationship to invasive carcinoma in the fallopian tubes and ovaries were assessed. Among the 45 cases of ovarian/peritoneal origin, carcinoma subtypes included 41 high-grade serous, 1 endometrioid, 1 mucinous, 1 high-grade, not otherwise specified, and 1 malignant mesodermal mixed tumor. TIC was identified in 24 cases (59%) of high-grade serous carcinoma but not among any of the other subtypes; therefore, the term serous TIC (STIC) is a more specific appellation. STICs were located in the fimbriated end of the tube in 22 cases (92%) and in the ampulla in 2 (8%); they were unilateral in 21 (88%) and bilateral in 3 (13%). STICs in the absence of an associated invasive carcinoma in the same tube were detected in 7 cases (30%) and with invasive carcinoma in the same tube in 17 (71%). Unilateral STICs were associated with bilateral ovarian involvement in 15 cases and unilateral (ipsilateral) ovarian involvement in 5 (the remaining case with a unilateral STIC had a primary peritoneal tumor with no ovarian involvement); the bilateral STICs were all associated with bilateral ovarian involvement. Six of the 7 primary tubal tumors were high-grade serous carcinomas, and 4 of these 6 (67%) had STICs. Based on conventional criteria, 70%, 17%, and 13% of high-grade serous carcinomas qualified for classification as ovarian, peritoneal, and tubal in origin, respectively; however, using STIC as a supplemental criterion to define a case as tubal in origin, the distribution was modified to 28%, 8%, and 64%, respectively. Features of tumors in the ovary that generally suggest metastatic disease (bilaterality, small size, nodular growth pattern, and surface plaques) were identified with similar frequency in cases with and without STIC and were, therefore, not predictive of tubal origin. The findings, showing that nearly 60% of high-grade pelvic (nonuterine) serous carcinomas are associated with STICs, are consistent with the proposal that the fallopian tube is the source of a majority of these tumors. If these findings can be validated by molecular studies that definitively establish that STIC is the earliest form of carcinoma rather than intraepithelial spread from adjacent invasive serous carcinoma of ovarian or peritoneal origin, they will have important clinical implications for screening, treatment, and prevention.
Outcome of Percutaneous Lumbar Synovial Cyst Rupture in Patients with Lumbar Radiculopathy.
Eshraghi, Yashar; Desai, Vimal; Cajigal Cajigal, Calvin; Tabbaa, Kutaiba
2016-01-01
Lumbar synovial cysts can result from spondylosis of facet joints. These cysts can encroach on adjacent nerve roots, causing symptoms of radiculopathy. Currently the only definitive treatment for these symptoms is surgery, which may involve laminectomy or laminotomy, with or without spinal fusion. Surgery has been reported to successfully relieve radicular pain in 83.5% of patients by Zhenbo et al. Little information is available concerning the efficacy and outcome of percutaneous fluoroscopic synovial cyst rupture for treatment of facet joint synovial cysts. The goal of this investigation was to assess the efficacy of fluoroscopically guided lumbar synovial cyst rupture, in particular for its relief of radicular symptoms and its potential to reduce the need for surgical intervention. Retrospective evaluation of a case series. University hospital and urban public health care system. With approval from the Institutional Review Board of Case Western Reserve University/ MetroHealth Medical Center, we reviewed the medical charts of patients with lumbar radiculopathy who underwent percutaneous lumbar synovial cyst rupture. The 30 patients in the cohort were treated by one pain specialist between 2006 and 2013. These patients were diagnosed with moderate to severe lower back pain, radiculopathy, and ranged in age from 42 to 80 years. Patients were followed up for a minimum of 6 months and up to 24 months. Pre- and post-procedure pain assessments were reviewed by clinical chart review. In addition post-procedure pain assessments and duration of pain relief were obtained with telephone interviews. Pain had been reported by the patients using a numeric rating scale of 0 - 10 (0 = no pain; 10 = worst possible pain). Charts were reviewed to determine if surgery was eventually performed to correct radicular symptoms. More than 6 months of pain relief was achieved in 14/30 patients (46%) and between one and 6 months of pain relief was achieved in 7/30 patients (23.3%). Nine patients (30.0%) had recurrence of the synovial cyst requiring repeat rupture and 6 patients (20.0%) required surgical intervention for cyst removal. A Wilcoxon signed-rank test demonstrated that the difference in numeric pain rating scale scores before and after the procedure was statistically significant (P < 0.0001). The average pain reduction was 71.2%. No complications were reported. The results are limited by the retrospective nature of the data collection and the lack of detailed information regarding patients' functional improvement. Rupture of percutaneous lumbar synovial cysts in patients with lumbar radiculopathy was associated with immediate relief of radicular symptoms. In 80% of the patients, synovial cyst rupture eliminated the need for surgical interventions over the measured term. This minimally invasive procedure helps relieve pain in a subset of a patient population associated with these characteristics and is useful for management of this condition. Cyst expansion and failure to rupture with possible neuronal compression are the potential complications of this procedure. This complication did not occur in the study population. Fluoroscopically guided lumbar synovial cyst rupture, lumbar synovial cyst, lumbar zygapophyseal joint cyst, nonsurgical intervention, radiculopathy, spondylosis.
Maximizing Lumen Gain With Directional Atherectomy.
Stanley, Gregory A; Winscott, John G
2016-08-01
To describe the use of a low-pressure balloon inflation (LPBI) technique to delineate intraluminal plaque and guide directional atherectomy in order to maximize lumen gain and achieve procedure success. The technique is illustrated in a 77-year-old man with claudication who underwent superficial femoral artery revascularization using a HawkOne directional atherectomy catheter. A standard angioplasty balloon was inflated to 1 to 2 atm during live fluoroscopy to create a 3-dimensional "lumenogram" of the target lesion. Directional atherectomy was performed only where plaque impinged on the balloon at a specific fluoroscopic orientation. The results of the LPBI technique were corroborated with multimodality diagnostic imaging, including digital subtraction angiography, intravascular ultrasound, and intra-arterial pressure measurements. With the LPBI technique, directional atherectomy can routinely achieve <10% residual stenosis, as illustrated in this case, thereby broadly supporting a no-stent approach to lower extremity endovascular revascularization. © The Author(s) 2016.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jones, A.
With the current Maintenance of Certification (MOC) requirement for a practice quality improvement (PQI) project every 3 years, we all (well, most of us) find ourselves searching for projects that are both manageable and likely to have a positive impact on our clinical practice. In this session we will walk through the use of the Plan, Do, Study, Act (PDSA) cycle to address a common finding in practices where fluoroscopically guided interventions (FGI) are performed: variation in procedural doses among physicians. We will also examine strategies to secure physician support using carrots, not sticks. Learning Objectives: Review the PDSA cyclemore » and its application to PQI. Discuss strategies for action in the example presented. Examine strategies for successful group PQI projects. A. Kyle Jones: Owner, FluoroSafety Joseph R. Steele: Consultant, FluoroSafety.« less
Multifocal Aspergillus terreus discospondylitis in two German shepherd dogs.
Berry, W L; Leisewitz, A L
1996-12-01
Multifocal fungal (Aspergillus terreus) discospondylitis was diagnosed in 2 German shepherd dogs. In one dog, the aetiology was established by means of fluoroscopic-guided disc aspiration, cytology and culture of disc material and urine. Disseminated aspergillosis was confirmed at necropsy and A. terreus cultured from numerous organs in this dog. The aetiology in the other dog was not established until therapeutic failure forced surgical curettage of disc material from which the fungus was cultured. Ketoconazole therapy failed to effect an improvement, and at necropsy, disease was localised to the spinal column, with A. terreus cultured from the affected discs and associated vertebrae. Immunodeficiency was suspected in both cases. In the case of disseminated disease a reduced lymphocyte blastogenic response was demonstrated. Reduced IgA was shown in both cases. The German shepherd breed seems to be predisposed to Aspergillus infections and IgA deficiency.
Kang, Keum Nae; Kim, Tae Woong; Koh, Jin Woo; Oh, Han Byeol; Mun, Jong-Uk; Seo, Mi Sook; Kim, Young Uk
2017-06-01
Transforaminal epidural glucocorticoids administration is widely performed for the management of lumbosacral radiculopathy. However, it may worsen the condition of patients with type 2 diabetes mellitus (DM). Polydeoxyribonucleotide (PDRN) was recently noted as a substitute for glucocorticoids. A 44-year-old male patient was admitted to our pain clinic with symptoms of low back pain with severe pain and tingling sensation of left posterolateral leg. He had type 2 DM medicated with Glimepiride and Metformin. Blood glucose level was 367 mg/dL. He declined to use glucocorticoid. He was diagnosed as left foraminal disc protrusion at L4-5, left subarticular disc protrusion at L5-S1. Fluoroscopically guided transforaminal epidural PDRN injections were carried out. The patient was followed up for more than 6 months and demonstrated good improvement in lumbosacral radiculopathy without any complications. This is the first successful report on epidural injection of PDRN.
Treatment of lymphangiomas in children: an update of Picibanil (OK-432) sclerotherapy.
Greinwald, J H; Burke, D K; Sato, Y; Poust, R I; Kimura, K; Bauman, N M; Smith, R J
1999-10-01
Picibanil (OK-432) is a sclerosing agent derived from a low-virulence strain of Streptococcus pyogenes that induces regression of macrocystic lymphangiomas. This report describes a prospective, nonrandomized trial to evaluate the efficacy of Picibanil in the treatment of 13 affected children ranging in age from 1 to 94 months. On average, 4.1 fluoroscopically guided intracystic injections were performed per child, with an average total dose of 0.56 mg of Picibanil. As judged by physical examination and radiographic studies, 5 children (42%) showed a complete or substantial response, and 2 children (16%) showed an intermediate response. No response was seen in 5 children (42%), 2 of whom had massive craniofacial lymphangioma. Factors that contribute to failure with Picibanil sclerotherapy are the presence of a significant microcystic component to the lesion, massive craniofacial involvement, and previous surgical resection. Macrocystic lymphangiomas of the infratemporal fossa or cervical area have the best response to therapy.
[The history and development of computer assisted orthopaedic surgery].
Jenny, J-Y
2006-10-01
Computer assisted orthopaedic surgery (CAOS) was developed to improve the accuracy of surgical procedures. It has improved dramatically over the last years, being transformed from an experimental, laboratory procedure into a routine procedure theoretically available to every orthopaedic surgeon. The first field of application of computer assistance was neurosurgery. After the application of computer guided spinal surgery, the navigation of total hip and knee joints became available. Currently, several applications for computer assisted surgery are available. At the beginning of navigation, a preoperative CT-scan or several fluoroscopic images were necessary. The imageless systems allow the surgeon to digitize patient anatomy at the beginning of surgery without any preoperative imaging. The future of CAOS remains unknown, but there is no doubt that its importance will grow in the next 10 years, and that this technology will probably modify the conventional practice of orthopaedic surgery.
... if you have risk factors for an ectopic pregnancy Causes A tubal pregnancy — the most common type of ectopic pregnancy — happens ... smoke, the greater the risk. Complications An ectopic pregnancy can cause your fallopian tube to burst open. Without treatment, ...
Histopathologic changes in fallopian tubes subsequent to sterilization procedures.
Stock, R J
1983-01-01
Longitudinal serial and serial step sections of fallopian tubes from more than 100 patients, subsequent to tubal sterilization procedures, were examined. Thirteen of these patients had pregnancies following their sterilizations. The histologic findings at the previous surgical sites were compatible with what would be expected for a normal healing process. Evidence for a unique tubal epithelial process, as suggested by the terms "endosalpingiosis" or "recanalization," was lacking. Likewise, the author found no evidence of tuboperitoneal fistula formation and/or the subsequent occurrence of pregnancy secondary to localized endometriosis. The histologic notations of proximal luminal dilatation, plical attenuation, chronic inflammatory infiltrates with pseudopolyp formation, and the findings of plical thickening in the distal segment of remaining tube after an interruption type of procedure seem to be associated with the length of time from the sterilization procedure. These may be factors related to the apparent reduced success rate, with time, of microsurgical reanastomotic procedures.
[Laparoscopic sterilization with electrocautery: complications and reliability (author's transl)].
Bänninger, U; Kunz, J; Schreiner, W E
1979-05-01
1084 laparoscopic sterilizations were evaluated in a retrospective study at the Universitäts-Frauenklinik Zürich. The operative and early postoperative complications and the reliability of the method were analysed and compared to the results in the literature. Based on a cumulative statistical analysis 0,5% intraoperative complications required laparotomy, the main indications being haemorrhages and bowel injuries. Failed attempts were encountered in one of 150 patients, the main causes of which were adhaesions and difficulties at establishing pneumoperitoneum. The failure rate of the laparoscopic electrocoagulation of the fallopian tube after a long-term follow-up was about 0,5%, 20--25% of these were ectopic pregnancies. The transection of the fallopian tubes did not diminish the pregnancy rate, but the risk of bleeding was considerably higher with this technic. Concurrently performed therapeutic abortion or preceeeding laparotomy did not increase the operative complication rate.
Subserosal misplacement of Essure device manifested by late-onset acute pelvic pain.
Mahmoud, Mohamad S; Fridman, Dmitry; Merhi, Zaher O
2009-12-01
To increase awareness of the potential to present with late-onset acute pelvic pain secondary to subserosal misplacement of an Essure device (Conceptus Inc., Mountain View, CA). Case report. University-affiliated teaching hospital. A 30-year-old woman who was seen with severe left lower quadrant pain 4 months after elective sterilization with an Essure device placed under local anesthesia. Mild to moderate resistance was encountered in the placement of the device in the left fallopian tube. Hysterosalpingogram showing patency of the left fallopian tube and operative laparoscopy. Laparoscopic removal of the Essure device with left salpingectomy. The patient was free of pain and was discharged home the same day of the laparoscopic procedure. This report reinforces the need to consider a misplaced Essure device in the differential diagnosis of late-onset acute pelvic pain in women who had difficult placement of the device.
Nature of "basal" and "reserve" cells in oviductal and cervical epithelium in man.
Peters, W M
1986-01-01
The epithelium of the human fallopian tube (oviduct) and cervix were studied by histological, immunohistological, and ultrastructural methods with a view to establishing the nature of the so called "basal" and "reserve" cells. The results indicated that the "basal" cells of the oviductal epithelia were T lymphocytes, with a predominance of T cytotoxic and suppressor cells. A more heterogeneous inflammatory cell population was present in cervical epithelium, although once again T cytotoxic and suppressor cells were the most numerous subtype. The intraepithelial inflammatory cells were quite distinct from the cells commonly referred to as "reserve" cells (reserve cell hyperplasia), which have epithelial characteristics. The origin of the "reserve" cells is unclear, but they seem to arise within the epithelium. They probably represent an early sign of squamous metaplasia. The lymphoid tissue of fallopian tube and endocervix shows similarities with that of the endometrium and mucosal associated lymphoid tissue in general. Images PMID:2937810
DOE Office of Scientific and Technical Information (OSTI.GOV)
Foulot, H.; Lefebvre, G.; Jagueux, M.
This experiment investigates CO/sub 2/-laser-induced histological effects on fallopian tubes obtained during hysterectomies in women. Tubal transversal sections were performed at isthmic and ampullar sites. Forty strips were available for histological study of the cut section area. The role of different parameters such as radiation power and beam fractionation (continuous versus pulsed) on tissue lesions was assessed. In tubal microsurgery, the CO/sub 2/ laser can be used as a scalpel with the predominant advantage of minimal tissular alterations. As a result of this study, our recommended parameters are the following: radiation power, 7-10 W; beam focalization zone, 0.2 mm; energymore » density, 20,000-35,000 W/cm2; continuous operation; moving speed, 1 cm/s.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lang, Erich K.; Dunaway, Herbert E.
2000-11-15
Purpose: The efficacy of selective salpingography (SS) and transcervical recanalization (TCR) in diagnosis, categorization, and determination of optimal treatment modality for fallopian tube obstruction was investigated.Methods: SS and, in some patients, TCR was performed in 430 patients with a diagnosis of obstruction of one or both fallopian tubes, as determined by hysterosalpingograms (HSG). All patients (age 21-46 years) had an infertility problem for at least 18 months.Results: In 196 patients, 325 tubes were patent on SS. TCR recanalized 243 tubes in 176 patients. Disease of the distal tube was demonstrated in 66 patients. There were 39 live babies in amore » group of 176 patients with successful TCR. Best live birth rate was in 7 of 12 (58%) patients with underlying endometriosis, followed by postsurgical strictures in inflammatory disease, 6 of 31 (19%), and salpingitis isthmica nodosa in 25 of 168 (15%). There were no pregnancies in patients with cobblestone pattern of the distal tubes.Conclusions: SS and TCR were capable of correcting obstruction of the proximal tubes in 243 of 465 tubes in 176 of 234 patients (75%). With patency of the proximal tube restored, the distal tube could be assessed for changes indicative of damage to the ciliated epithelium which was likely to reduce the ability to become pregnant. This allowed for the triage of patients into groups benefiting from the relatively inexpensive and low complication TCR or patients in need of in vitro fertilization or similar assisted reproductive technologies.« less
Dosimetry during intramedullary nailing of the tibia.
Kirousis, George; Delis, Harry; Megas, Panagiotis; Lambiris, Elias; Panayiotakis, George
2009-10-01
Intramedullary nailing under fluoroscopic guidance is a common operation. We studied the intraoperative radiation dose received by both the patient and the personnel. 25 intramedullary nailing procedures of the tibia were studied. All patients suffered from tibial fractures and were treated using the Grosse-Kempf intramedullary nail, with free-hand technique for fixation of the distal screws, under fluoroscopic guidance. The exposure, at selected positions, was recorded using an ion chamber, while the dose area product (DAP) was measured with a DAP meter, attached to the tube head. Thermoluminescent dosimeters (TLDs) were used to derive the occupational dose to the personnel, and also to monitor the surface dose on the gonads of some of the patients. The mean operation time was 101 (48-240) min, with a mean fluoroscopic time of 72 seconds and a mean DAP value of 75 cGy x cm(2). The surface dose to the gonads of the patients was less than 8.8 mGy during any procedure, and thus cannot be considered to be a contraindication for the use of this technique. Occupational dose differed substantially between members of the operating personnel, the maximum dose recorded being to the operator of the fluoroscopic equipment (0.11 mSv). Our findings underscore the care required by the primary operator not to exceed the dose constraint of 10 mSv per year. The rest of the operating personnel, although they do not receive very high doses, should focus on the dose optimization of the technique.
Mattyasovszky, S G; Kurth, A A; Drees, P; Gemidji, J; Thomczyk, S; Kafchitsas, K
2014-10-01
Minimally invasive cement augmentation of painful osteoporotic vertebral compression fractures in elderly patients. Painful osteoporotic vertebral compression fractures in elderly patients (> 65 years of age) after conservative therapy failure. Painful aggressive primary tumors of the spine or osteolytic metastases to the spine with high risk of vertebral fracture in the palliative care setting. General contraindications for surgical interventions. Local soft-tissue infection. Osteomyelitis, discitis or systemic infection. Coagulopathy refractory to treatment or bleeding diathesis. Asymptomatic vertebral compression fractures. Burst of the posterior vertebral column with high degree of spinal canal stenosis. Primary or metastatic spinal tumors with epidural growth. Prone position on a radiolucent operating table. Fluoroscopic localization of the fractured vertebra using two conventional C-arm devices (anteroposterior and lateral views). Fluoroscopic localization of the fractured vertebra using two conventional C-arm devices (anteroposterior and lateral views). An introducer is inserted through a small skin incision into the pedicle under fluoroscopic guidance. To create a site- and size-specific three-dimensional cavity in the center of the fractured vertebra, the navigational VertecoR™ MidLine Osteotome was inserted through the correctly sited introducer and guided fluoroscopically. As the MidLine Osteotome allows angulation of the tip up to 90° by rotating the handle, a cavity over the midline of the vertebral body can mainly be created through one pedicle. The radiofrequency activated cohesive ultrahigh viscosity PMMA cement (ER(2) bone cement) is injected stepwise on demand by remote control under continuous pressure from the hydraulic assembly into the vertebral body. Bed rest for 6 h postoperatively in supine position. Early mobilization without a corset on the day of surgery. Specific back and abdominal exercises that strengthen the back and abdominal muscles. Pain dependent increase of weight bearing. Continue osteoporosis therapy and start specific drug therapy according to the local guidlines if necessary. In all, 44 patients (29 women, 15 men) with a mean age of 73.5 years with a total of 62 painful osteoporotic vertebral fractures were treated with RF kyphoplasty from May 2009 until July 2010, and followed over a period of 12 months. The mean operating time per patient was 36.2 min, the operating time per vertebra was 25.7 min. All the patients studied experienced an early and persistent significant pain relief even 12 months after therapy (8 ± 1.4 vs. 2.7 ± 1.9) according to the visual analogue pain scale. According to the Oswestry Disability Index (ODI) as a disease-specific disability measure all the patients improved significantly (p < 0.001) in the level of disability after operative treatment (56.2 ± 18.8 vs. 34.5 ± 16.6). Cement leakage was detected in 17 out of 62 (27.4 %) augmented vertebrae, whereas all the patients with cement leakage remained asymptomatic. One patient had subsequent vertebral fractures after a period of 6 months.
... Stage I Description: Three-panel drawing of stage IA, IB, and IC; the first panel (stage IA) shows cancer inside one ovary. The second panel ( ... fallopian tubes, uterus, cervix, and vagina. In stage IA, cancer is found inside a single ovary or ...
Durvalumab and Tremelimumab in Combination With First-Line Chemotherapy in Advanced Solid Tumors
2018-05-16
Small Cell Lung Carcinoma; Carcinoma, Squamous Cell of Head and Neck; Stomach Neoplasms; Triple Negative Breast Neoplasms; Ovarian Neoplasms; Fallopian Tube Neoplasms; Peritoneal Neoplasms; Esophagogastric Junction Neoplasms; Carcinoma, Pancreatic Ductal; Esophageal Squamous Cell Carcinoma
Wang, Kundong; Chen, Bing; Lu, Qingsheng; Li, Hongbing; Liu, Manhua; Shen, Yu; Xu, Zhuoyan
2018-05-15
Endovascular interventional surgery (EIS) is performed under a high radiation environment at the sacrifice of surgeons' health. This paper introduces a novel endovascular interventional surgical robot that aims to reduce radiation to surgeons and physical stress imposed by lead aprons during fluoroscopic X-ray guided catheter intervention. The unique mechanical structure allowed the surgeon to manipulate the axial and radial motion of the catheter and guide wire. Four catheter manipulators (to manipulate the catheter and guide wire), and a control console which consists of four joysticks, several buttons and two twist switches (to control the catheter manipulators) were presented. The entire robotic system was established on a master-slave control structure through CAN (Controller Area Network) bus communication, meanwhile, the slave side of this robotic system showed highly accurate control over velocity and displacement with PID controlling method. The robotic system was tested and passed in vitro and animal experiments. Through functionality evaluation, the manipulators were able to complete interventional surgical motion both independently and cooperatively. The robotic surgery was performed successfully in an adult female pig and demonstrated the feasibility of superior mesenteric and common iliac artery stent implantation. The entire robotic system met the clinical requirements of EIS. The results show that the system has the ability to imitate the movements of surgeons and to accomplish the axial and radial motions with consistency and high-accuracy. Copyright © 2018 John Wiley & Sons, Ltd.
Faulkner, Austin R; Bourgeois, Austin C; Bradley, Yong C; Hudson, Kathleen B; Heidel, R Eric; Pasciak, Alexander S
2015-05-01
Fluoroscopically guided lumbar puncture (FGLP) is a commonly performed procedure with increased success rates relative to bedside technique. However, FGLP also exposes both patient and staff to ionizing radiation. The purpose of this study was to determine if the use of a simulation-based FGLP training program using an original, inexpensive lumbar spine phantom could improve operator confidence and efficiency, while also reducing patient dose. A didactic and simulation-based FGLP curriculum was designed, including a 1-hour lecture and hands-on training with a lumbar spine phantom prototype developed at our institution. Six incoming post-graduate year 2 (PGY-2) radiology residents completed a short survey before taking the course, and each resident practiced 20 simulated FGLPs using the phantom before their first clinical procedure. Data from the 114 lumbar punctures (LPs) performed by the six trained residents (prospective cohort) were compared to data from 514 LPs performed by 17 residents who did not receive simulation-based training (retrospective cohort). Fluoroscopy time (FT), FGLP success rate, and indication were compared. There was a statistically significant reduction in average FT for the 114 procedures performed by the prospective study cohort compared to the 514 procedures performed by the retrospective cohort. This held true for all procedures in aggregate, LPs for myelography, and all procedures performed for a diagnostic indication. Aggregate FT for the prospective group (0.87 ± 0.68 minutes) was significantly lower compared to the retrospective group (1.09 ± 0.65 minutes) and resulted in a 25% reduction in average FT (P = .002). There was no statistically significant difference in the number of failed FGLPs between the two groups. Our simulation-based FGLP curriculum resulted in improved operator confidence and reduced FT. These changes suggest that resident procedure efficiency was improved, whereas patient dose was reduced. The FGLP training program was implemented by radiology residents and required a minimal investment of time and resources. The LP spine phantom used during training was inexpensive, durable, and effective. In addition, the phantom is compatible with multiple modalities including fluoroscopy, computed tomography, and ultrasound and could be easily adapted to other applications such as facet injections or joint arthrograms. Copyright © 2015 AUR. Published by Elsevier Inc. All rights reserved.
Laparoscopic Filshie clip sterilization and selective use of the methylene blue dye test.
Karoshi, Mahantesh; Yoong, Wai
2004-01-01
In laparoscopic Filshie clip sterilization, difficulties may arise in identifying the length of the fallopian tube, with the possibility of failure of sterilization. This article describes a novel intraoperative method of demonstrating adequate tubal closure.
... knowledge” about their bodies and health. What is cervical cancer? Cancer is a disease in which cells in the body grow out of control. Cancer ... for HPV— the virus that can cause precancerous cell changes and cervical cancer. Fallopian Tube Ovary Uterus Cervix Vagina Vulva www. ...
Female sterilization using an elasticated silicone ring.
Cave, D G
1979-06-16
This paper presents the experience, in a District General Hospital, of using an elasticated silicone ring applied to the Fallopian tubes by the laparoscope. It is concluded that this is a safe and effective method of female sterilization, with good patient acceptance.
Fernández-Gutiérrez, Fabiola; Martínez, Santiago; Rube, Martin A; Cox, Benjamin F; Fatahi, Mahsa; Scott-Brown, Kenneth C; Houston, J Graeme; McLeod, Helen; White, Richard D; French, Karen; Gueorguieva, Mariana; Immel, Erwin; Melzer, Andreas
2015-10-01
A methodological framework is introduced to assess and compare a conventional fluoroscopy protocol for peripheral angioplasty with a new magnetic resonant imaging (MRI)-guided protocol. Different scenarios were considered during interventions on a perfused arterial phantom with regard to time-based and cognitive task analysis, user experience and ergonomics. Three clinicians with different expertise performed a total of 43 simulated common iliac angioplasties (9 fluoroscopic, 34 MRI-guided) in two blocks of sessions. Six different configurations for MRI guidance were tested in the first block. Four of them were evaluated in the second block and compared to the fluoroscopy protocol. Relevant stages' durations were collected, and interventions were audio-visually recorded from different perspectives. A cued retrospective protocol analysis (CRPA) was undertaken, including personal interviews. In addition, ergonomic constraints in the MRI suite were evaluated. Significant differences were found when comparing the performance between MRI configurations versus fluoroscopy. Two configurations [with times of 8.56 (0.64) and 9.48 (1.13) min] led to reduce procedure time for MRI guidance, comparable to fluoroscopy [8.49 (0.75) min]. The CRPA pointed out the main influential factors for clinical procedure performance. The ergonomic analysis quantified musculoskeletal risks for interventional radiologists when utilising MRI. Several alternatives were suggested to prevent potential low-back injuries. This work presents a step towards the implementation of efficient operational protocols for MRI-guided procedures based on an integral and multidisciplinary framework, applicable to the assessment of current vascular protocols. The use of first-user perspective raises the possibility of establishing new forms of clinical training and education.
Percutaneous imaging-guided interventions for acute biliary disorders in high surgical risk patients
Donkol, Ragab Hani; Latif, Nahed Abdel; Moghazy, Khaled
2010-01-01
AIM: To evaluate the efficacy of percutaneous imaging-guided biliary interventions in the management of acute biliary disorders in high surgical risk patients. METHODS: One hundred and twenty two patients underwent 139 percutaneous imaging-guided biliary interventions during the period between January 2007 to December 2009. The patients included 73 women and 49 men with a mean age of 61 years (range 35-90 years). Fifty nine patients had acute biliary obstruction, 26 patients had acute biliary infection and 37 patients had abnormal collections. The procedures were performed under computed tomography (CT)- (73 patients), sonographic- (41 patients), and fluoroscopic-guidance (25 patients). Success rates and complications were determined. The χ2 test with Yates’ correction for continuity was applied to compare between these procedures. A P value < 0.05 was considered significant. RESULTS: The success rates for draining acute biliary obstruction under CT- , fluoroscopy- or ultrasound-guidance were 93.3%, 62.5% and 46.1%, respectively with significant P values (P = 0.026 and 0.002, respectively). In acute biliary infection, successful drainage was achieved in 22 patients (84.6%). The success rates in patients drained under ultrasound- and CT-guidance were 46.1% and 88.8%, respectively and drainage under CT-guidance was significantly higher (P = 0.0293). In 13 patients with bilomas, percutaneous drainage was successful in 11 patients (84.6%). Ten out of 12 cases with hepatic abscesses were drained with a success rate of 83.3%. In addition, the success rate of drainage in 12 cases with pancreatic pseudocysts was 83.3%. The reported complications were two deaths, four major and seven minor complications. CONCLUSION: Percutaneous imaging-guided biliary interventions help to promptly diagnose and effectively treat acute biliary disorders. They either cure the disorders or relieve sepsis and jaundice before operations. PMID:21160698
DOE Office of Scientific and Technical Information (OSTI.GOV)
Freitas, Ricardo Miguel Costa de, E-mail: ricardomcfreitas@gmail.com; Andrade, Celi Santos, E-mail: celis.andrade@hotmail.com; Caldas, José Guilherme Mendes Pereira, E-mail: jgmpcaldas@uol.com.br
PurposeThis study was designed to present the feasibility of an in vivo image-guided percutaneous cryoablation of the porcine vertebral body.MethodsThe institutional animal care committee approved this study. Cone-beam computed tomography (CBCT)-guided vertebral cryoablations (n = 22) were performed in eight pigs with short, 2-min, single or double-freezing protocols. Protective measures to nerves included dioxide carbon (CO{sub 2}) epidural injections and spinal canal temperature monitoring. Clinical, radiological, and pathological data with light (n = 20) or transmission electron (n = 2) microscopic analyses were evaluated after 6 days of clinical follow-up and euthanasia.ResultsCBCT/fluoroscopic-guided transpedicular vertebral body cryoprobe positioning and CO{sub 2} epidural injection were successful in all procedures. No majormore » complications were observed in seven animals (87.5 %, n = 8). A minor complication was observed in one pig (12.5 %, n = 1). Logistic regression model analysis showed the cryoprobe-spinal canal (Cp-Sc) distance as the most efficient parameter to categorize spinal canal temperatures lower than 19 °C (p < 0.004), with a significant Pearson’s correlation test (p < 0.041) between the Cp-Sc distance and the lowest spinal canal temperatures. Ablation zones encompassed pedicles and the posterior wall of the vertebral bodies with an inflammatory rim, although no inflammatory infiltrate was depicted in the surrounding neural structures at light microscopy. Ultrastructural analyses evidenced myelin sheath disruption in some large nerve fibers, although neurological deficits were not observed.ConclusionsCBCT-guided vertebral cryoablation of the porcine spine is feasible under a combination of a short freezing protocol and protective measures to the surrounding nerves. Ultrastructural analyses may be helpful assess the early modifications of the nerve fibers.« less
Attaluri, Anilchandra; Seshadri, Madhav; Mirpour, Sahar; Wabler, Michele; Marinho, Thomas; Furqan, Muhammad; Zhou, Haoming; De Paoli, Silvia; Gruettner, Cordula; Gilson, Wesley; DeWeese, Theodore; Garcia, Monica; Ivkov, Robert; Liapi, Eleni
2016-01-01
Purpose/objective The aim of this study was to develop and investigate the properties of a magnetic iron oxide nanoparticle–ethiodised oil formulation for image-guided thermal therapy of liver cancer. Materials and methods The formulation comprises bionised nano-ferrite (BNF) nanoparticles suspended in ethiodised oil, emulsified with polysorbate 20 (BNF-lip). Nanoparticle size was measured via photon correlation spectroscopy and transmission electron microscopy. In vivo thermal therapy capability was tested in two groups of male Foxn1nu mice bearing subcutaneous HepG2 xenograft tumours. Group I (n =12) was used to screen conditions for group II (n =48). In group II, mice received one of BNF-lip (n =18), BNF alone (n =16), or PBS (n =14), followed by alternating magnetic field (AMF) hyperthermia, with either varied duration (15 or 20 min) or amplitude (0, 16, 20, or 24 kA/m). Image-guided fluoroscopic intra-arterial injection of BNF-lip was tested in New Zealand white rabbits (n =10), bearing liver VX2 tumours. The animals were subsequently imaged with CT and 3 T MRI, up to 7 days post-injection. The tumours were histopathologically evaluated for distribution of BNF-lip. Results The BNF showed larger aggregate diameters when suspended in BNF-lip, compared to clear solution. The BNF-lip formulation produced maximum tumour temperatures with AMF >20 kA/m and showed positive X-ray visibility and substantial shortening of T1 and T2 relaxation time, with sustained intratumoural retention up to 7 days post-injection. On pathology, intratumoural BNF-lip distribution correlated well with CT imaging of intratumoural BNF-lip distribution. Conclusion The BNF-lip formulation has favourable thermal and dual imaging capabilities for image-guided thermal therapy of liver cancer, suggesting further exploration for clinical applications. PMID:27151045
Tandon, Vivek; Raheja, Amol; Suri, Ashish; Chandra, P Sarat; Kale, Shashank S; Kumar, Rajinder; Garg, Ajay; Kalaivani, Mani; Pandey, Ravindra M; Sharma, Bhawani S
2017-03-01
Till date there are no randomized trials to suggest the superiority of intra-operative magnetic resonance imaging (IOMRI) guided trans-sphenoidal pituitary resection over two dimensional fluoroscopic (2D-F) guided resections. We conducted this trial to establish the superiority of IOMRI in pituitary surgery. Primary objective was to compare extent of tumor resection between the two study arms. It was a prospective, randomized, outcome assessor and statistician blinded, two arm (A: IOMRI, n=25 and B: 2D-F, n=25), parallel group clinical trial. 4 patients from IOMRI group cross-over to 2D-F group and were consequently analyzed in latter group, based on modified intent to treat method. A total of 50 patients were enrolled till completion of trial (n=25 in each study arm). Demographic profile and baseline parameters were comparable among the two arms (p>0.05) except for higher number of endoscopic procedures and experienced neurosurgeons (>10years) in arm B (p=0.02, 0.002 respectively). Extent of resection was similar in both study arms (A, 94.9% vs B, 93.6%; p=0.78), despite adjusting for experience of operating surgeon and use of microscope/endoscope for surgical resection. We observed that use of IOMRI helped optimize the extent of resection in 5/20 patients (25%) for pituitary tumor resection in-group A. Present study failed to observe superiorty of IOMRI over conventional 2D-F guided resection in pituitary macroadenoma surgery. By use of this technology, younger surgeons could validate their results intra-operatively and hence could increase EOR without causing any increase in complications. Copyright © 2016 Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cazzato, Roberto Luigi, E-mail: gigicazzato@hotmail.it; Garnon, Julien, E-mail: juleiengarnon@gmail.com; Ramamurthy, Nitin, E-mail: nitin-ramamurthy@hotmail.com
ObjectiveTo describe a novel percutaneous image-guided technique using a large-bore biopsy system to retrieve foreign bodies (FBs) accidentally retained during non-vascular interventional procedures.Materials and MethodsBetween May 2013 and October 2015, five patients underwent percutaneous retrieval of five iatrogenic FBs, including a biopsy needle tip in the femoral head following osteoblastoma biopsy and radiofrequency ablation (RFA); a co-axial needle shaft within a giant desmoid tumour following cryoablation; and three post-vertebroplasty cement tails within paraspinal muscles. All FBs were retrieved immediately following original procedures under local or general anaesthesia, using combined computed tomography (CT) and fluoroscopic guidance. The basic technique involved positioningmore » a 6G trocar sleeve around the FB long axis and co-axially advancing an 8G biopsy needle to retrieve the FB within the biopsy core. Retrospective chart review facilitated analysis of procedures, FBs, technical success, and complications.ResultsMean FB size was 23 mm (range 8–74 mm). Four FBs were located within 10 mm of non-vascular significant anatomic structures. The basic technique was successful in 3 cases; 2 cases required technical modifications including using a stiff guide-wire to facilitate retrieval in the case of the post-cryoablation FB; and using the central mandrin of the 6G trocar to push a cement tract back into an augmented vertebra when initial retrieval failed. Overall technical success (FB retrieval or removal to non-hazardous location) was 100 %, with no complications.ConclusionPercutaneous image-guided retrieval of iatrogenic FBs using a large-bore biopsy system is a feasible, safe, effective, and versatile technique, with potential advantages over existing methods.« less
Three-Station Three-dimensional Bolus-Chase MR Angiography with Real-time Fluoroscopic Tracking
Johnson, Casey P.; Weavers, Paul T.; Borisch, Eric A.; Grimm, Roger C.; Hulshizer, Thomas C.; LaPlante, Christine C.; Rossman, Phillip J.; Glockner, James F.; Young, Phillip M.
2014-01-01
Purpose To determine the feasibility of using real-time fluoroscopic tracking for bolus-chase magnetic resonance (MR) angiography of peripheral vasculature to image three stations from the aortoiliac bifurcation to the pedal arteries. Materials and Methods This prospective study was institutional review board approved and HIPAA compliant. Eight healthy volunteers (three men; mean age, 48 years; age range, 30–81 years) and 13 patients suspected of having peripheral arterial disease (five men; mean age, 67 years; age range, 47–81 years) were enrolled and provided informed consent. All subjects were imaged with the fluoroscopic tracking MR angiographic protocol. Ten patients also underwent a clinical computed tomographic (CT) angiographic runoff examination. Two readers scored the MR angiographic studies for vessel signal intensity and sharpness and presence of confounding artifacts and venous contamination at 35 arterial segments. Mean aggregate scores were assessed. The paired MR angiographic and CT angiographic studies also were scored for visualization of disease, reader confidence, and overall diagnostic quality and were compared by using a Wilcoxon signed rank test. Results Real-time fluoroscopic tracking performed well technically in all studies. Vessel segments were scored good to excellent in all but the following categories: For vessel signal intensity and sharpness, the abdominal aorta, iliac arteries, distal plantar arteries, and plantar arch were scored as fair to good; and for presence of confounding artifacts, the abdominal aorta and iliac arteries were scored as fair. The MR angiograms and CT angiograms did not differ significantly in any scoring category (reader 1: P = .50, .39, and .39; reader 2: P = .41, .61, and .33, respectively). CT scores were substantially better in 20% (four of 20) and 25% (five of 20) of the pooled evaluations for the visualization of disease and overall image quality categories, respectively, versus 5% (one of 20) for MR scores in both categories. Conclusion Three-station bolus-chase MR angiography with real-time fluoroscopic tracking provided high-spatial-resolution arteriograms of the peripheral vasculature, enabled precise triggering of table motion, and compared well with CT angiograms. © RSNA, 2014 Online supplemental material is available for this article. PMID:24635676
DOE Office of Scientific and Technical Information (OSTI.GOV)
Paik, Nam Chull, E-mail: pncspine@gmail.com
2016-07-15
PurposeA technique for computed tomography fluoroscopy (CTF)-guided intraarticular (IA) sacroiliac joint (SIJ) injection was devised to limit procedural time and radiation dose.MethodsOur Institutional Review Board approved this retrospective analysis and waived the requirement for informed consent. Overall, 36 consecutive diagnostic or therapeutic IA SIJ injections (unilateral, 20; bilateral, 16) performed in 34 patients (female, 18; male, 16) with a mean age of 45.5 years (range 20–76 years) under CTF guidance were analyzed, assessing technical success (i.e., IA contrast spread), procedural time, and radiation dose.ResultsAll injections were successful from a technical perspective and were free of serious complications. Respective median proceduralmore » times and effective doses of SIJ injection were as follows: unilateral, 5.28 min (range 3.58–8.00 min) and 0.11 millisievert (mSv; range 0.07–0.24 mSv); and bilateral, 6.72 min (range 4.17–21.17 min) and 0.11 mSv (range 0.09–0.51 mSv).ConclusionsGiven the high rate of technical success achieved in limited time duration and with little radiation exposure, CTF-guided IA SIJ injection is a practical and low-risk procedure.« less
Graham, D Y; Smith, J L
1985-06-01
Balloon esophageal dilatation offers many theoretical advantages (safety, speed, and patient comfort) over dilatation with mercury-filled bougies or with the Eder-Puestow system. The authors used balloon dilators in 22 patients with dysphagia secondary to benign or malignant strictures. Dilatation was performed with fluoroscopic guidance, blindly, or by a combination of these techniques. For "blind" stricture dilatation, an Eder-Puestow spring-tipped guide wire is placed into the stomach using a fiberoptic endoscope. The distance from the incisor teeth to the stricture is measured, and the balloon shaft is marked to indicate when the middle of the balloon is within the stricture. Dilatation is then performed using the antegrade or, the preferred, retrograde technique. Finally, the dilated stricture is calibrated by pulling an inflated balloon through the previously strictured area without difficulty. An attempt was made to achieve an esophageal diameter of 15 mm at the initial dilatation episode, and patient discomfort was used as a guide as to the final diameter. The balloon dilatation technique was highly successful, and a stricture diameter of 15 mm (45-47 French) was achieved at the initial dilatation in most instances. Malignant strictures were easily dilated. Balloon dilatation is convenient, effective, quick, and potentially safer than the previous Eder-Puestow or mercury-filled bougie techniques.
Esposito, Francesco; Ambrosio, Concetta; De Fronzo, Simona; Panico, Maria Rita; D'Aprano, Marilena; Giugliano, Anna Marcella; Noviello, Domenico; Oresta, Patrizia
2015-06-01
Intussusception is one of the most common causes of paediatric emergency. Fluoroscopy-guided hydrostatic reduction is a common nonoperative management strategy for the treatment of intussusception. The role of pharmacological premedication in increasing the success rate of hydrostatic reduction is still controversial. The purpose of this study was to verify the presence of a possible correlation between pharmacological premedication and the percentage of hydrostatic reduction of intussusception in paediatric patients. This study considered children with a diagnosis of idiopathic intussusception treated at our hospital between January 2007 and June 2013. One group of patients underwent hydrostatic reduction by barium enema without any preliminary therapy. A second group of patients received pharmacological premedication with both a sedative and an anti-oedematous agent before the procedure. A total of 398 patients were treated with barium enema for therapeutic purposes. In the group of patients who received no premedication (n = 254), 165 (65 %) children achieved hydrostatic reduction of the intussusception. Among the patients who received pharmacological premedication prior to barium enema (n = 144), 122 (85 %) children achieved resolution of the intussusception. Our study shows that the use of pharmacological premedication is effective for the reduction of the intussusception, as its limit patient stress, fluoroscopic time and radiation dose.
Hysteroscopic tubal sterilization: a health economic literature review.
2013-01-01
Hysteroscopic sterilization is a minimally invasive alternative to laparoscopic tubal ligation for women who want permanent contraception. In contrast to the laparoscopic technique, a hysteroscope is used to pass permanent microinserts through the cervix and place them in the fallopian tubes. This procedure does not require local or general anesthesia and can be performed in an office setting. The objective of this analysis was to determine, based on published literature, the cost-effectiveness of hysteroscopic tubal sterilization (HS) compared with laparoscopic tubal ligation (LS) for permanent female sterilization. A systematic literature search was conducted for studies published between January 1, 2008, and December 11, 2012. Potentially relevant studies were identified based on the title and abstract. Cost-utility analyses (studies that report outcomes in terms of costs and quality-adjusted life-years) were prioritized for inclusion. When not available, cost-effectiveness, cost-benefit, and cost-consequence analyses were considered. Costing studies were considered in the absence of all other analyses. A total of 33 abstracts were identified. Three cost analyses were included. A retrospective chart review from Canada found that HS was $111 less costly than LS; a prospective activity-based cost management study from Italy reported that it was €337 less costly than LS; and the results of an American decision model showed that HS was $1,178 less costly than LS. All studies had limited applicability to the Ontario health care system due to differences in setting, resource use, and costs. Three cost analyses found that, although the HS procedure was more expensive due to the cost of the microinserts, HS was less costly than LS overall due to the shorter recovery time required. Hysteroscopic sterilization is a minimally invasive alternative to conventional tubal ligation for women who want a permanent method of contraception. Both approaches involve closing off the fallopian tubes, preventing the egg from moving down the tube and the sperm from reaching the egg. Tubal ligation is a surgical procedure to tie or seal the fallopian tubes, and it usually requires general anesthesia. In contrast, hysteroscopic tubal sterilization can be performed in 10 minutes in an office setting without general or even local anesthesia. A tiny device called a microinsert is inserted into each fallopian tube through the vagina, cervix, and uterus without surgery. An instrument called a hysteroscope allows the doctor to see inside the body for the procedure. Once the microinserts are in place, scar tissue forms around them and blocks the fallopian tubes. Health Quality Ontario commissioned a systematic review of published economic literature to determine whether hysteroscopic sterilization is cost-effective compared to tubal ligation. This review did not find any studies that reported results in terms of both costs and effectiveness or costs and quality-adjusted life-years. We did find 3 costing studies and included them in our review. All of these studies found that when hysteroscopic sterilization was performed as an outpatient procedure, it was less expensive than tubal ligation due to a shorter recovery time. However, none of the studies apply directly to Ontario because of differences in our health care system compared to those in the studies.
Mori, S
2014-05-01
To ensure accuracy in respiratory-gating treatment, X-ray fluoroscopic imaging is used to detect tumour position in real time. Detection accuracy is strongly dependent on image quality, particularly positional differences between the patient and treatment couch. We developed a new algorithm to improve the quality of images obtained in X-ray fluoroscopic imaging and report the preliminary results. Two oblique X-ray fluoroscopic images were acquired using a dynamic flat panel detector (DFPD) for two patients with lung cancer. The weighting factor was applied to the DFPD image in respective columns, because most anatomical structures, as well as the treatment couch and port cover edge, were aligned in the superior-inferior direction when the patient lay on the treatment couch. The weighting factors for the respective columns were varied until the standard deviation of the pixel values within the image region was minimized. Once the weighting factors were calculated, the quality of the DFPD image was improved by applying the factors to multiframe images. Applying the image-processing algorithm produced substantial improvement in the quality of images, and the image contrast was increased. The treatment couch and irradiation port edge, which were not related to a patient's position, were removed. The average image-processing time was 1.1 ms, showing that this fast image processing can be applied to real-time tumour-tracking systems. These findings indicate that this image-processing algorithm improves the image quality in patients with lung cancer and successfully removes objects not related to the patient. Our image-processing algorithm might be useful in improving gated-treatment accuracy.
Dosimetry during intramedullary nailing of the tibia
2009-01-01
Background Intramedullary nailing under fluoroscopic guidance is a common operation. We studied the intraoperative radiation dose received by both the patient and the personnel. Patients and methods 25 intramedullary nailing procedures of the tibia were studied. All patients suffered from tibial fractures and were treated using the Grosse-Kempf intramedullary nail, with free-hand technique for fixation of the distal screws, under fluoroscopic guidance. The exposure, at selected positions, was recorded using an ion chamber, while the dose area product (DAP) was measured with a DAP meter, attached to the tube head. Thermoluminescent dosimeters (TLDs) were used to derive the occupational dose to the personnel, and also to monitor the surface dose on the gonads of some of the patients. Results The mean operation time was 101 (48–240) min, with a mean fluoroscopic time of 72 seconds and a mean DAP value of 75 cGy·cm2. The surface dose to the gonads of the patients was less than 8.8 mGy during any procedure, and thus cannot be considered to be a contraindication for the use of this technique. Occupational dose differed substantially between members of the operating personnel, the maximum dose recorded being to the operator of the fluoroscopic equipment (0.11 mSv). Interpretation Our findings underscore the care required by the primary operator not to exceed the dose constraint of 10 mSv per year. The rest of the operating personnel, although they do not receive very high doses, should focus on the dose optimization of the technique. PMID:19916691
Does Breast or Ovarian Cancer Run in Your Family?
... receptors, progesterone receptors and human epidermal growth factor receptor 2.) Cancer in both breasts Breast cancer in a male relative Ovarian, fallopian tube, or primary peritoneal cancer Pancreatic cancer or high grade prostate cancer Breast, ovarian, pancreatic, or high grade prostate ...
2016-03-23
Urinary Bladder Neoplasms; Carcinoma, Transitional Cell; Ovarian Neoplasms; Fallopian Tube Neoplasms; Peritoneal Neoplasms; Carcinoma, Non-Small-Cell Lung; Carcinoma, Pancreatic Ductal; Tumor Virus Infections
Imaging techniques for assessment of tubal status
Panchal, Sonal; Nagori, Chaitanya
2014-01-01
Fallopian tubes make a vital portal for transfer of gametes and embryo. Tubal factor is responsible for infertility in 25-35% of cases. Hysterosalpingography (HSG) has been used to evaluate the uterine cavity and the tubal status since decades. It uses iodinated contrast and X-rays and is painful and inconvenient for patient. Laparoscopy is considered to be the gold standard for tubal evaluation, but is an operative procedure and needs anesthesia. Though ultrasound is a modality of choice for assessment of uterus and ovaries, it does not allow assessment of the fallopian tube unless there is any fluid surrounding it or inside the lumen. This fluid interface can be created artificially by introducing saline in the uterine cavity and fallopian tubes and scanning simultaneously. The procedure is named Saline infusion HSG. Saline infusion sonohysterosalpingography (SIS) can be done with B mode US and Doppler. SIS can demonstrate a patent tube but if blocked, the site of block cannot be demonstrated. Ultrasound contrast agents can be used for tubal assessment using contrast mode on the scanners. This procedure is known as hystero-contrast sonography (HyCoSy). This actually shows the passage of hyperechoic contrast agent through tubal lumen and delineates it and locates the site of block. Using the volume ultrasound may even make the demonstration of tubal status and fimbriae better. Results of HyCoSy have been found to correlate well with laparoscopic findings, which are a gold standard. It is recommended by National Institute for Health and Clinical Excellence as a primary investigation for tubal assessment in patients without any positive history of tubal damage and also can replace a second look laparoscopy. PMID:24829524
Samimi, Goli; Trabert, Britton; Duggan, Máire A; Robinson, Jennifer L; Coa, Kisha I; Waibel, Elizabeth; Garcia, Edna; Minasian, Lori M; Sherman, Mark E
2018-03-01
Many high-grade serous carcinomas initiate in fallopian tubes as serous tubal intraepithelial carcinoma (STIC), a microscopic lesion identified with specimen processing according to the Sectioning and Extensive Examination of the Fimbria protocol (SEE-Fim). Given that the tubal origin of these cancers was recently recognized, we conducted a survey of pathology practices to assess processing protocols that are applied to gynecologic surgical pathology specimens in clinical contexts in which finding STIC might have different implications. We distributed a survey electronically to the American Society for Clinical Pathology list-serve to determine practice patterns and compared results between practice types by chi-square (χ2) tests for categorical variables. Free text comments were qualitatively reviewed. Survey responses were received from 159 laboratories (72 academic, 87 non-academic), which reported diverse specimen volumes and percentage of gynecologic samples. Overall, 74.1% of laboratories reported performing SEE-Fim for risk-reducing surgical specimens (82.5% academic versus 65.7% non-academic, p < 0.05). In specimens from surgery for benign indications in which initial microscopic sections showed an unanticipated suspicious finding, 75.9% of laboratories reported using SEE-Fim to process the remainder of the specimen (94.8% academic versus 76.4% non-academic, p < 0.01), and 84.6% submitted the entire fimbriae. Changes in the theories of pathogenesis of high-grade serous carcinoma have led to implementation of pathology specimen processing protocols that include detailed analysis of the fallopian tubes. These results have implications for interpreting trends in cancer incidence data and considering the feasibility of developing a bank of gynecologic tissues containing STIC or early cancer precursors. Published by Elsevier Inc.
Herzog, Thomas J.; Monk, Bradley J.; Rose, Peter G.; Braly, Patricia; Hines, Jeffrey F.; Bell, Maria C.; Wenham, Robert M.; Secord, Angeles Alvarez; Roman, Lynda D.; Einstein, Mark H.; Drake, Richard D.; Childs, Barrett H.
2017-01-01
Objective To determine the safety and efficacy of the novel combination of docetaxel, oxaliplatin, and bevacizumab as first-line treatment of advanced cancer of the ovary, peritoneum or fallopian tube after initial debulking surgery. Methods Eligible patients (stage IB-IV) were treated with 6 cycles of oxaliplatin (85 mg/m2), docetaxel (75 mg/m2), and bevacizumab (15 mg/kg) every 3 weeks, followed by single-agent bevacizumab 15 mg/kg every 3 weeks to complete one year of therapy. The primary endpoint was 12-month progression-free survival (PFS). Results A total of 132 patients (80 with measurable disease at baseline; 52 with non-measurable, evaluable disease at baseline) enrolled and received study treatment. At diagnosis, 76.5% of patients had stage III disease and 20% had stage IV. 62.9% were optimally cytoreduced. The most common grade 3/4 adverse events were neutropenia (42.4%), leukopenia (13.6%), hypertension (8.3%), fatigue (6.1%), and nausea (6.1%). One patient (0.8%) had a fatal gastrointestinal perforation. The best overall confirmed response rate (complete response + partial response [measurable disease subgroup]) was 58.6% (95% CI 49%, 67%). CA-125 response rates for the measurable and non-measurable disease subgroups were 83.0% and 81.5%, respectively. The 12-month PFS rate for the measurable disease subgroup was 65.7% (95% CI 53.4%, 76.7%); median PFS was 16.3 (95% CI 12.6, 19.6) months. Median overall survival was 47.3 (95% CI 34.1, upper limit not applicable) months. Conclusions This novel treatment regimen may provide a promising therapeutic approach for women with ovarian, primary peritoneal, or fallopian tube carcinoma. No unanticipated safety concerns were identified. PMID:24476788
Naderi, Tayebeh; Kazerani, Fatemeh; Bahraminpoor, Abbas
2012-11-01
Damage of the fallopian tube after sexually transmitted diseases like Chlamydia trachomatis, is an important risk factor for ectopic pregnancy (EP). The study was designed to assess the prevalence of C. trachomatis infection in patients with EP in the southeastern part of Iran. The polymerase chain reaction (PCR) on fallopian tube tissue was applied to detect Chlamydia DNA in 42 patients with EP (EP group) and 87 patients without EP (control group) who underwent tubal ligation. The same protocol was performed with urine samples taken from the husbands in both groups. Out of all studied females, 5 patients in the EP group were PCR-positive for C. trachomatis and none of the control group subjects was PCR-positive for C. trachomatis infection (P<0.05). Among the husbands, the PCR result was positive in the urine of 19 males (9 in the EP group and 10 in the control group). All PCR-positive women had husbands with PCR positive urine samples. No significant difference was found between Chlamydia infection in the EP and the control groups regarding age, duration of marriage, contraceptive method and history of infertility surgery and pelvic pain. There was no significant difference between prevalence of EP in women based on the PCR outcome in the husbands. The Chlamydia infection in men did not show any relation to the number of marriages. Based on our findings, it can be concluded that Chlamydia is an important risk factor of the fallopian tube damage and EP in our society. Therefore, screening programs and treatment of Chlamydia infection are recommended in young women and high risk women and men.
Schoolmeester, J Kenneth; Moyer, Ann M; Goodenberger, McKinsey L; Keeney, Gary L; Carter, Jodi M; Bakkum-Gamez, Jamie N
2017-12-01
Germline BRCA mutations account for a significant proportion of genetic/familial risk of breast and ovarian cancer (GBOC) susceptibility, but a broader spectrum of GBOC susceptibility genes has emerged in recent years. Genotype-to-phenotype correlations are known for some established forms of GBOC; however, whether such correlations exist for less common GBOC variants is unclear. We reviewed our institution's experience with non-BRCA GBOC, looking specifically for trends in pathologic and clinical features. Eighteen women with deleterious germline mutations in RAD51C (5 patients), BARD1 (1 patient), BRIP1 (2 patients), PALB2 (3 patients), MUTYH (2 patients), or CHEK2 (5 patients) were identified between January 2011 and December 2016. Thirteen (72%) of 18 patients developed carcinoma of the breast, fallopian tube, or ovary, with 1 patient developing 2 separate primary neoplasms. Twelve (86%) of 14 tumors occurred in the breast. One (7%) arose in the fallopian tube and another (7%) arose in the ovary. Evidence of genotype-phenotype correlation was not identified. However, some data suggest that the type of alteration in select genes may influence tumor behavior and patient outcome. In our PALB2 mutation cohort, 2 patients with frameshift mutations led to early onset and rapid progression to stage IV breast cancer in contrast to stage IA breast cancer in 1 patient with a nonsense mutation. Despite no apparent genotype-phenotype trends, our data indicate that some loss-of-function variants in PALB2 may lead to differences in tumor behavior and patient outcome. Copyright © 2017 Elsevier Inc. All rights reserved.
Noriega, David C; Hernández-Ramajo, Rubén; Rodríguez-Monsalve Milano, Fiona; Sanchez-Lite, Israel; Toribio, Borja; Ardura, Francisco; Torres, Ricardo; Corredera, Raul; Kruger, Antonio
2017-01-01
Pedicle screws in spinal surgery have allowed greater biomechanical stability and higher fusion rates. However, malposition is very common and may cause neurologic, vascular, and visceral injuries and compromise mechanical stability. The purpose of this study was to compare the malposition rate between intraoperative computed tomography (CT) scan assisted-navigation and free-hand fluoroscopy-guided techniques for placement of pedicle screw instrumentation. This is a prospective, randomized, observational study. A total of 114 patients were included: 58 in the assisted surgery group and 56 in the free-hand fluoroscopy-guided surgery group. Analysis of screw position was assessed using the Heary classification. Breach severity was defined according to the Gertzbein classification. Radiation doses were evaluated using thermoluminescent dosimeters, and estimates of effective and organ doses were made based on scan technical parameters. Consecutive patients with degenerative disease, who underwent surgical procedures using the free-hand, or intraoperative navigation technique for placement of transpedicular instrumentation, were included in the study. Forty-four out of 625 implanted screws were malpositioned: 11 (3.6%) in the navigated surgery group and 33 (10.3%) in the free-hand group (p<.001). Screw position according to the Heary scale was Grade II (4 navigated surgery, 6 fluoroscopy guided), Grade III (3 navigated surgery, 11 fluoroscopy guided), Grade IV (4 navigated surgery, 16 fluoroscopy guided), and Grade V (1 fluoroscopy guided). There was only one symptomatic case in the conventional surgery group. Breach severity was seven Grade A and four Grade B in the navigated surgery group, and eight Grade A, 24 Grade B, and one Grade C in free-hand fluoroscopy-guided surgery group. Radiation received per patient was 5.8 mSv (4.8-7.3). The median dose received in the free-hand fluoroscopy group was 1 mGy (0.8-1.1). There was no detectable radiation level in the navigation-assisted surgery group, whereas the effective dose was 10 µGy in the free-hand fluoroscopy-guided surgery group. Malposition rate, both symptomatic and asymptomatic, in spinal surgery is reduced when using CT-guided placement of transpedicular instrumentation compared with placement under fluoroscopic guidance, with radiation values within the safety limits for health. Larger studies are needed to determine risk-benefit in these patients. Copyright © 2016 Elsevier Inc. All rights reserved.
Luani, Blerim; Zrenner, Bernhard; Basho, Maksim; Genz, Conrad; Rauwolf, Thomas; Tanev, Ivan; Schmeisser, Alexander; Braun-Dullaeus, Rüdiger C
2018-01-01
Stochastic damage of the ionizing radiation to both patients and medical staff is a drawback of fluoroscopic guidance during catheter ablation of cardiac arrhythmias. Therefore, emerging zero-fluoroscopy catheter-guidance techniques are of great interest. We investigated, in a prospective pilot study, the feasibility and safety of the cryothermal (CA) slow-pathway ablation in patients with symptomatic atrioventricular-nodal-re-entry-tachycardia (AVNRT) using solely intracardiac echocardiography (ICE) for endovascular and endocardial catheter visualization. Twenty-five consecutive patients (mean age 55.6 ± 12.0 years, 17 female) with ECG-documentation or symptoms suggesting AVNRT underwent an electrophysiology study (EPS) in our laboratory utilizing ICE for catheter navigation. Supraventricular tachycardia was inducible in 23 (92%) patients; AVNRT was confirmed by appropriate stimulation maneuvers in 20 (80%) patients. All EPS in the AVNRT subgroup could be accomplished without need for fluoroscopy, relying solely on ICE-guidance. CA guided by anatomical location and slow-pathway potentials was successful in all patients, median cryo-mappings = 6 (IQR:3-10), median cryo-ablations = 2 (IQR:1-3). Fluoroscopy was used to facilitate the trans-septal puncture and localization of the ablation substrate in the remaining 3 patients (one focal atrial tachycardia and two atrioventricular-re-entry-tachycardias). Mean EPS duration in the AVNRT subgroup was 99.8 ± 39.6 minutes, ICE guided catheter placement 11.9 ± 5.8 minutes, time needed for diagnostic evaluation 27.1 ± 10.8 minutes, and cryo-application duration 26.3 ± 30.8 minutes. ICE-guided zero-fluoroscopy CA in AVNRT patients is feasible and safe. Real-time visualization of the true endovascular borders and cardiac structures allow for safe catheter navigation during the ICE-guided EPS and might be an alternative to visualization technologies using geometry reconstructions. © 2017 Wiley Periodicals, Inc.
Drugs Approved for Ovarian, Fallopian Tube, or Primary Peritoneal Cancer
This page lists cancer drugs approved by the Food and Drug Administration (FDA) for ovarian cancer. The list includes generic names, brand names, and common drug combinations, which are shown in capital letters. The drug names link to NCI's Cancer Drug Information summaries.
Weigert, Monika; Gruber, Diego; Pernicka, Elisabeth; Bauer, Peter; Feichtinger, Wilfried
2009-01-01
To investigate the incidence of Tubal Ectopic Pregnancies (TEP) in IVF-ET patients with respect to the status of the fallopian tubes after a previous TEP. This retrospective study compares patients undergoing 481 IVF-ET cycles after conservatively or surgically treated TEP(s) with a Control Group (idiopathic or male factor for IVF-ET indication). Medical reports of surgery and/or hysterosalpingograms prior to the IVF cycles classified the status of the fallopian tubes. 12 TEPs (8.95%/Pregnancies (PR)) occurred in the Study Group. In the Control Group one TEP (0.75%/PR; p < 0.001) was found. Smoking increased the probability of TEPs (p = 0.0028) and of pathological pregnancies (abortion, biochemical and ectopic PR; (p = 0.0411)). For statistic evolution logistic regression (PROC GENMOD) and a repeated measure model were applied. Women with a previous TEP should be informed about the significantly increased risk for a further TEP in IVF-ET treatment, especially if they are smoking.
Fluoroscopic tomography. [for body section synthesis
NASA Technical Reports Server (NTRS)
Baily, N. A.; Crepeau, R. L.; Lasser, E. C.
1974-01-01
A fluoroscopic tomography system capable of synthesizing body sections at a number of levels within the body has been developed. The synthesized body sections may lie either in a range of planes parallel to, tilted with respect to, skewed with respect to, or both tilted and skewed with respect to the plane of motion of the X-ray tube target. In addition, body sections can be presented which are contoured to the patient's anatomy. That is to say, they may even encompass such complex surfaces as a quadratic hyperplane. In addition, tomograms of organs in motion can be imaged.
2015-12-03
Fallopian Tube Cancer; Female Reproductive Cancer; Ovarian Carcinosarcoma; Ovarian Sarcoma; Recurrent Ovarian Epithelial Cancer; Recurrent Uterine Sarcoma; Stage III Ovarian Epithelial Cancer; Stage III Uterine Sarcoma; Stage IV Ovarian Epithelial Cancer; Stage IV Uterine Sarcoma; Uterine Carcinosarcoma; Uterine Leiomyosarcoma
Rucaparib Approved as Maintenance Therapy for Ovarian Cancer
FDA has expanded its approval of rucaparib for women with ovarian, fallopian tube, or primary peritoneal cancer. As this Cancer Currents blog post explains, it can now be used to treat women with recurrent disease whose tumors shrank after subsequent treatment with a platinum-based chemotherapy.
2015-08-03
Leydig Cell Tumor; Ovarian Sarcoma; Ovarian Stromal Cancer; Pseudomyxoma Peritonei; Recurrent Cervical Cancer; Recurrent Endometrial Carcinoma; Recurrent Fallopian Tube Cancer; Recurrent Ovarian Epithelial Cancer; Recurrent Ovarian Germ Cell Tumor; Recurrent Primary Peritoneal Cavity Cancer; Recurrent Uterine Sarcoma; Recurrent Vaginal Cancer; Recurrent Vulvar Cancer
Ramírez, I; Pantrigo, J J; Montemayor, A S; López-Pérez, A E; Martín-Fontelles, M I; Brookes, S J H; Abalo, R
2017-08-01
When available, fluoroscopic recordings are a relatively cheap, non-invasive and technically straightforward way to study gastrointestinal motility. Spatiotemporal maps have been used to characterize motility of intestinal preparations in vitro, or in anesthetized animals in vivo. Here, a new automated computer-based method was used to construct spatiotemporal motility maps from fluoroscopic recordings obtained in conscious rats. Conscious, non-fasted, adult, male Wistar rats (n=8) received intragastric administration of barium contrast, and 1-2 hours later, when several loops of the small intestine were well-defined, a 2 minutes-fluoroscopic recording was obtained. Spatiotemporal diameter maps (Dmaps) were automatically calculated from the recordings. Three recordings were also manually analyzed for comparison. Frequency analysis was performed in order to calculate relevant motility parameters. In each conscious rat, a stable recording (17-20 seconds) was analyzed. The Dmaps manually and automatically obtained from the same recording were comparable, but the automated process was faster and provided higher resolution. Two frequencies of motor activity dominated; lower frequency contractions (15.2±0.9 cpm) had an amplitude approximately five times greater than higher frequency events (32.8±0.7 cpm). The automated method developed here needed little investigator input, provided high-resolution results with short computing times, and automatically compensated for breathing and other small movements, allowing recordings to be made without anesthesia. Although slow and/or infrequent events could not be detected in the short recording periods analyzed to date (17-20 seconds), this novel system enhances the analysis of in vivo motility in conscious animals. © 2017 John Wiley & Sons Ltd.
Lever, Teresa E.; Braun, Sabrina M.; Brooks, Ryan T.; Harris, Rebecca A.; Littrell, Loren L.; Neff, Ryan M.; Hinkel, Cameron J.; Allen, Mitchell J.; Ulsas, Mollie A.
2015-01-01
This study adapted human videofluoroscopic swallowing study (VFSS) methods for use with murine disease models for the purpose of facilitating translational dysphagia research. Successful outcomes are dependent upon three critical components: test chambers that permit self-feeding while standing unrestrained in a confined space, recipes that mask the aversive taste/odor of commercially-available oral contrast agents, and a step-by-step test protocol that permits quantification of swallow physiology. Elimination of one or more of these components will have a detrimental impact on the study results. Moreover, the energy level capability of the fluoroscopy system will determine which swallow parameters can be investigated. Most research centers have high energy fluoroscopes designed for use with people and larger animals, which results in exceptionally poor image quality when testing mice and other small rodents. Despite this limitation, we have identified seven VFSS parameters that are consistently quantifiable in mice when using a high energy fluoroscope in combination with the new murine VFSS protocol. We recently obtained a low energy fluoroscopy system with exceptionally high imaging resolution and magnification capabilities that was designed for use with mice and other small rodents. Preliminary work using this new system, in combination with the new murine VFSS protocol, has identified 13 swallow parameters that are consistently quantifiable in mice, which is nearly double the number obtained using conventional (i.e., high energy) fluoroscopes. Identification of additional swallow parameters is expected as we optimize the capabilities of this new system. Results thus far demonstrate the utility of using a low energy fluoroscopy system to detect and quantify subtle changes in swallow physiology that may otherwise be overlooked when using high energy fluoroscopes to investigate murine disease models. PMID:25866882
Kim, Pyeong Hwa; Song, Ho-Young; Park, Jung-Hoon; Zhou, Wei-Zhong; Na, Han Kyu; Cho, Young Chul; Jun, Eun Jung; Kim, Jun Ki; Kim, Guk Bae
2017-03-01
To evaluate clinical outcomes of fluoroscopic removal of retrievable self-expandable metal stents (SEMSs) for malignant oesophageal strictures, to compare clinical outcomes of three different removal techniques, and to identify predictive factors of successful removal by the standard technique (primary technical success). A total of 137 stents were removed from 128 patients with malignant oesophageal strictures. Primary overall technical success and removal-related complications were evaluated. Logistic regression models were constructed to identify predictive factors of primary technical success. Primary technical success rate was 78.8 % (108/137). Complications occurred in six (4.4 %) cases. Stent location in the upper oesophagus (P=0.004), stricture length over 8 cm (P=0.030), and proximal granulation tissue (P<0.001) were negative predictive factors of primary technical success. If granulation tissue was present at the proximal end, eversion technique was more frequently required (P=0.002). Fluoroscopic removal of retrievable SEMSs for malignant oesophageal strictures using three different removal techniques appeared to be safe and easy. The standard technique is safe and effective in the majority of patients. The presence of proximal granulation tissue, stent location in the upper oesophagus, and stricture length over 8 cm were negative predictive factors for primary technical success by standard extraction and may require a modified removal technique. • Fluoroscopic retrievable SEMS removal is safe and effective. • Standard removal technique by traction is effective in the majority of patients. • Three negative predictive factors of primary technical success were identified. • Caution should be exercised during the removal in those situations. • Eversion technique is effective in cases of proximal granulation tissue.
Marker Configuration Model-Based Roentgen Fluoroscopic Analysis.
Garling, Eric H; Kaptein, Bart L; Geleijns, Koos; Nelissen, Rob G H H; Valstar, Edward R
2005-04-01
It remains unknown if and how the polyethylene bearing in mobile bearing knees moves during dynamic activities with respect to the tibial base plate. Marker Configuration Model-Based Roentgen Fluoroscopic Analysis (MCM-based RFA) uses a marker configuration model of inserted tantalum markers in order to accurately estimate the pose of an implant or bone using single plane Roentgen images or fluoroscopic images. The goal of this study is to assess the accuracy of (MCM-Based RFA) in a standard fluoroscopic set-up using phantom experiments and to determine the error propagation with computer simulations. The experimental set-up of the phantom study was calibrated using a calibration box equipped with 600 tantalum markers, which corrected for image distortion and determined the focus position. In the computer simulation study the influence of image distortion, MC-model accuracy, focus position, the relative distance between MC-models and MC-model configuration on the accuracy of MCM-Based RFA were assessed. The phantom study established that the in-plane accuracy of MCM-Based RFA is 0.1 mm and the out-of-plane accuracy is 0.9 mm. The rotational accuracy is 0.1 degrees. A ninth-order polynomial model was used to correct for image distortion. Marker-Based RFA was estimated to have, in a worst case scenario, an in vivo translational accuracy of 0.14 mm (x-axis), 0.17 mm (y-axis), 1.9 mm (z-axis), respectively, and a rotational accuracy of 0.3 degrees. When using fluoroscopy to study kinematics, image distortion and the accuracy of models are important factors, which influence the accuracy of the measurements. MCM-Based RFA has the potential to be an accurate, clinically useful tool for studying kinematics after total joint replacement using standard equipment.
Stanley, Jeremy C; Robinson, Kerian G; Devitt, Brian M; Richmond, Anneka K; Webster, Kate E; Whitehead, Timothy S; Feller, Julian A
2016-03-01
There are numerous methods available to assist surgeons in the accurate correction of varus alignment during medial opening wedge high tibial osteotomy (MOWHTO). Preoperative planning performed with radiographs or more recently intraoperative computer navigation software has been used. The aim of the study was to compare the accuracy of computer navigated versus non-navigated techniques to correct varus alignment of the knee. The preoperative and postoperative radiographs of 117 knees that underwent MOWHTO were investigated to assess radiographic limb alignment 12-months postoperatively. The desired correction was defined as a weight bearing line (Mikulicz point {MP}) 58% of the width of the tibial plateau from the medial tibial margin. Sixty-five knees were corrected using a conventional technique and 52 knees were corrected using computer navigation. The mean MP percentage was 59% in the navigated group, compared with 56% in the fluoroscopic group (p=0.183). 51.9% of the navigation knees were corrected to within five percent of the desired correction, in contrast to 38.5% of the fluoroscopically corrected knees (p=0.15). 71.2% of the navigated knees were corrected to within 10% of the desired correction, compared with 63.1% of the fluoroscopically corrected knees (p=0.36). Large preoperative deformities were more accurately corrected with navigation assistance (57% vs 49%, p=0.049). No statistically significant difference was found in the radiographic correction of varus alignment twelve months postoperatively between navigated and fluoroscopic techniques of MOWHTO. However, a subgroup analysis demonstrated that larger preoperative varus deformities may be more accurately corrected using computer navigation. Copyright © 2016 Elsevier B.V. All rights reserved.
Wang, Junqiang; Wang, Yu; Zhu, Gang; Chen, Xiangqian; Zhao, Xiangrui; Qiao, Huiting; Fan, Yubo
2018-06-01
Spatial positioning accuracy is a key issue in a computer-assisted orthopaedic surgery (CAOS) system. Since intraoperative fluoroscopic images are one of the most important input data to the CAOS system, the quality of these images should have a significant influence on the accuracy of the CAOS system. But the regularities and mechanism of the influence of the quality of intraoperative images on the accuracy of a CAOS system have yet to be studied. Two typical spatial positioning methods - a C-arm calibration-based method and a bi-planar positioning method - are used to study the influence of different image quality parameters, such as resolution, distortion, contrast and signal-to-noise ratio, on positioning accuracy. The error propagation rules of image error in different spatial positioning methods are analyzed by the Monte Carlo method. Correlation analysis showed that resolution and distortion had a significant influence on spatial positioning accuracy. In addition the C-arm calibration-based method was more sensitive to image distortion, while the bi-planar positioning method was more susceptible to image resolution. The image contrast and signal-to-noise ratio have no significant influence on the spatial positioning accuracy. The result of Monte Carlo analysis proved that generally the bi-planar positioning method was more sensitive to image quality than the C-arm calibration-based method. The quality of intraoperative fluoroscopic images is a key issue in the spatial positioning accuracy of a CAOS system. Although the 2 typical positioning methods have very similar mathematical principles, they showed different sensitivities to different image quality parameters. The result of this research may help to create a realistic standard for intraoperative fluoroscopic images for CAOS systems. Copyright © 2018 John Wiley & Sons, Ltd.