Kwon, Young Ho; Kwon, Se Hwan; Oh, Joo Hyeong; Jeong, Kyung Hwan; Lee, Tae Won
2014-06-01
To assess the efficacy of fluoroscopic guide wire manipulation in patients with malfunctioning peritoneal dialysis (PD) catheters that were initially placed by interventional radiologists under fluoroscopic guidance. From January 2002 to April 2012, 52 patients (mean age, 52.8 y ± 2.10s; range, 12-79 y) with malfunctioning PD catheters in whom fluoroscopic guide wire manipulation was performed were retrospectively reviewed. Technical success, clinical success, and complications were evaluated. Technical success was defined as fluoroscopically verified, successful catheter repositioning and adequate dialysate drainage after the procedure. Clinical success was defined as maintenance of PD catheter function for at least 30 days after the manipulation. During the study period, 72 manipulations (68 initial manipulations and 4 remanipulations) for malfunctioning PD catheters were done. The technical success rate was 74% (50 of 68) for initial manipulations and 75% (3 of 4) for remanipulations. The overall clinical success rate was 47% (32 of 68) for initial manipulations and 0% (0 of 4) for remanipulations. The primary causes of catheter malfunction were extraluminal obstruction by omental wrapping or adhesions in 43 of 68 cases (63.2%) and catheter malposition in 25 of 68 (36.8%) cases. There were no procedure-related major complications. Fluoroscopic guide wire manipulation in patients with malfunctioning PD catheters initially placed by interventional radiologists is a simple procedure, an effective way of prolonging PD catheter life, and a recommended procedure before invasive surgical procedures. Copyright © 2014 SIR. Published by Elsevier Inc. All rights reserved.
Fluoroscopic image-guided intervention system for transbronchial localization
NASA Astrophysics Data System (ADS)
Rai, Lav; Keast, Thomas M.; Wibowo, Henky; Yu, Kun-Chang; Draper, Jeffrey W.; Gibbs, Jason D.
2012-02-01
Reliable transbronchial access of peripheral lung lesions is desirable for the diagnosis and potential treatment of lung cancer. This procedure can be difficult, however, because accessory devices (e.g., needle or forceps) cannot be reliably localized while deployed. We present a fluoroscopic image-guided intervention (IGI) system for tracking such bronchoscopic accessories. Fluoroscopy, an imaging technology currently utilized by many bronchoscopists, has a fundamental shortcoming - many lung lesions are invisible in its images. Our IGI system aligns a digitally reconstructed radiograph (DRR) defined from a pre-operative computed tomography (CT) scan with live fluoroscopic images. Radiopaque accessory devices are readily apparent in fluoroscopic video, while lesions lacking a fluoroscopic signature but identifiable in the CT scan are superimposed in the scene. The IGI system processing steps consist of: (1) calibrating the fluoroscopic imaging system; (2) registering the CT anatomy with its depiction in the fluoroscopic scene; (3) optical tracking to continually update the DRR and target positions as the fluoroscope is moved about the patient. The end result is a continuous correlation of the DRR and projected targets with the anatomy depicted in the live fluoroscopic video feed. Because both targets and bronchoscopic devices are readily apparent in arbitrary fluoroscopic orientations, multiplane guidance is straightforward. The system tracks in real-time with no computational lag. We have measured a mean projected tracking accuracy of 1.0 mm in a phantom and present results from an in vivo animal study.
The MEPUC concept adapts the C-arm fluoroscope to image-guided surgery.
Suhm, Norbert; Müller, Paul; Bopp, Urs; Messmer, Peter; Regazzoni, Pietro
2004-06-01
Image-guided surgery requires surgeons to be able to manipulate the imaging modality themselves and without delay. Intraoperative fluoroscopic imaging does not meet this requirement as the C-arm fluoroscope cannot be operated or positioned by the surgeons themselves. The Motorized Exact Positioning Unit for C-arm (MEPUC) concept aims to optimize the workflow of positioning the C-arm fluoroscope. The hardware component of the MEPUC equips the fluoroscope with electric stepping motors. The software component allows the surgeon to control the fluoroscope's movements. The study presented here showed that translational movements within the x-y plane are most frequently performed when positioning the C-arm fluoroscope. Furthermore, reproducing a former projection was found to be a frequent task during image-guided procedures. In our opinion, the MEPUC concept adapts the fluoroscope to image-guided surgery. The most important improvement being definition of a bidirectional data exchange between the surgeon and the C-arm fluoroscope: positioning data from the surgeon to the C-arm fluoroscope and-subsequently-image information from C-arm fluoroscope to the surgeon.
Scale-space for empty catheter segmentation in PCI fluoroscopic images.
Bacchuwar, Ketan; Cousty, Jean; Vaillant, Régis; Najman, Laurent
2017-07-01
In this article, we present a method for empty guiding catheter segmentation in fluoroscopic X-ray images. The guiding catheter, being a commonly visible landmark, its segmentation is an important and a difficult brick for Percutaneous Coronary Intervention (PCI) procedure modeling. In number of clinical situations, the catheter is empty and appears as a low contrasted structure with two parallel and partially disconnected edges. To segment it, we work on the level-set scale-space of image, the min tree, to extract curve blobs. We then propose a novel structural scale-space, a hierarchy built on these curve blobs. The deep connected component, i.e. the cluster of curve blobs on this hierarchy, that maximizes the likelihood to be an empty catheter is retained as final segmentation. We evaluate the performance of the algorithm on a database of 1250 fluoroscopic images from 6 patients. As a result, we obtain very good qualitative and quantitative segmentation performance, with mean precision and recall of 80.48 and 63.04% respectively. We develop a novel structural scale-space to segment a structured object, the empty catheter, in challenging situations where the information content is very sparse in the images. Fully-automatic empty catheter segmentation in X-ray fluoroscopic images is an important and preliminary step in PCI procedure modeling, as it aids in tagging the arrival and removal location of other interventional tools.
Ultrasound-guided lumbar puncture in pediatric patients: technical success and safety.
Pierce, David B; Shivaram, Giri; Koo, Kevin S H; Shaw, Dennis W W; Meyer, Kirby F; Monroe, Eric J
2018-06-01
Disadvantages of fluoroscopically guided lumbar puncture include delivery of ionizing radiation and limited resolution of incompletely ossified posterior elements. Ultrasound (US) allows visualization of critical soft tissues and the cerebrospinal fluid (CSF) space without ionizing radiation. To determine the technical success and safety of US-guided lumbar puncture in pediatric patients. A retrospective review identified all patients referred to interventional radiology for lumbar puncture between June 2010 and June 2017. Patients who underwent lumbar puncture with fluoroscopic guidance alone were excluded. For the remaining procedures, technical success and procedural complications were assessed. Two hundred and one image-guided lumbar punctures in 161 patients were included. Eighty patients (43%) had previously failed landmark-based attempts. One hundred ninety-six (97.5%) patients underwent lumbar puncture. Five procedures (2.5%) were not attempted after US assessment, either due to a paucity of CSF or unsafe window for needle placement. Technical success was achieved in 187 (95.4%) of lumbar punctures attempted with US guidance. One hundred seventy-seven (90.3%) were technically successful with US alone (age range: 2 days-15 years, weight range: 1.9-53.1 kg) and an additional 10 (5.1%) were successful with US-guided thecal access and subsequent fluoroscopic confirmation. Three (1.5%) cases were unsuccessful with US guidance but were subsequently successful with fluoroscopic guidance. Of the 80 previously failed landmark-based lumbar punctures, 77 (96.3%) were successful with US guidance alone. There were no reported complications. US guidance is safe and effective for lumbar punctures and has specific advantages over fluoroscopy in pediatric patients.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Damilakis, J; Perisinakis, K; Solomou, G
Purpose: The aim of this method was to provide dosimetric data on conceptus dose for the pregnant employee who participates in fluoroscopically-guided interventional procedures. Methods: Scattered air-kerma dose rates were obtained for 17 fluoroscopic projections involved in interventional procedures. These projections were simulated on an anthropomorphic phantom placed on the examination table supine. The operating theater was divided into two grids relative to the long table sides. Each grid consisted of 33 cells spaced 0.50 m apart. During the simulated exposures, at each cell, scatter air-kerma rate was measured at 110 cm from the floor i.e. at the height ofmore » the waist of the pregnant worker. Air-kerma rates were divided by the dose area product (DAP) rate of each exposure to obtain normalized data. For each projection, measurements were performed for 3 kVp and 3 filtration values i.e. for 9 different x-ray spectra. All measurements were performed by using a modern C-arm angiographic system (Siemens Axiom Artis, Siemens, Germany) and a radiation meter equipped with an ionization chamber. Results: The results consist of 153 iso-dose maps, which show the spatial distribution of DAP-normalized scattered air-kerma doses at the waist level of a pregnant worker. Conceptus dose estimation is possible using air-kerma to embryo/fetal dose conversion coefficients published in a previous study (J Cardiovasc Electrophysiol, Vol. 16, pp. 1–8, July 2005). Using these maps, occupationally exposed pregnant personnel may select a working position for a certain projection that keeps abdominal dose as low as reasonably achievable. Taking into consideration the regulatory conceptus dose limit for occupational exposure, determination of the maximum workload allowed for the pregnant personnel is also possible. Conclusion: Data produced in this work allow for the anticipation of conceptus dose and the determination of the maximum workload for a pregnant worker from any fluoroscopically-guided interventional procedure. This study was supported by the Greek Ministry of Education and Religious Affairs, General Secretariat for Research and Technology, Operational Program ‘Education and Lifelong Learning’, ARISTIA (Research project: CONCERT)« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee, Woong Hee; Kim, Jin Hyoung, E-mail: m1fenew@daum.net; Park, Jung-Hun
Purpose: Little was known about the safety and long-term efficacy of fluoroscopically guided balloon dilation for postintubation tracheal stenosis. The purpose of this study was to evaluate the safety and long-term efficacy of fluoroscopically guided balloon dilation in patients with postintubation tracheal stenosis. Methods: From February 2000 to November 2010, 14 patients underwent fluoroscopically guided balloon dilation for postintubation tracheal stenosis. Technical success, clinical success, and complications were evaluated. Patients were followed up for recurrent symptoms. Results: In all patients, fluoroscopically guided balloon dilation was technically and clinically successful with no major complications. Following the initial procedure, six patients (43more » %) remained asymptomatic during a follow-up period. Obstructive symptoms recurred in eight patients (57 %) within 6 months (mean, 1.7 months), who were treated with repeat balloon dilation (n = 4) and other therapies. Of the four patients who underwent repeat balloon dilation, three became asymptomatic. One patient became asymptomatic after a third balloon dilation. On long-term (mean, 74 months) follow-up, 71 % of patients experienced relief of symptoms following fluoroscopically guided balloon dilation. Conclusions: Fluoroscopically guided balloon dilation may be safe, is easy to perform, and resulted in effective treatment in patients with postintubation tracheal stenosis.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jones, A; Pasciak, A
Purpose: The purpose of this study was to determine if a relationship between indirect dose metrics and PSD could be established for fluoroscopically-guided interventional cardiology procedures. Methods: PSD were measured directly using XR-RV3 radiochromic film for 94 consecutive fluoroscopically guided interventional cardiology procedures performed at two sites. Procedures were both diagnostic and therapeutic in nature. Radiation dose structured reports (RDSR) were collected for each procedure and used to calculate indirect estimates of PSD which were compared to the measured PSD. Reference air kerma (Ka,r) was also compared to the measured PSD. Pearson’s correlation coefficient was calculated for each metric andmore » metrics were compared to measured PSD using a two-tailed t-test. Data were log transformed prior to statistical analysis. Results: Both Ka,r and the calculated PSD were closely correlated with measured PSD at each sites (Ka,r: 0.92 and 0.86, indirect PSD: 0.91 and 0.88). At one site, neither Ka,r nor indirect PSD was significantly different from the measured PSD (p = 0.22 and p=0.054, respectively), while at the second site both Ka,r and indirect PSD were significantly higher than measured PSD (p<0.0001 and p<0.0001, respectively). In almost all cases, both Ka,r and indirect PSD overestimated the true PSD. Conclusions: The use of a range of gantry angles and table positions, along with variation in procedural imaging requirements, limits the utility of indirect dose metrics for predicting PSD for interventional cardiology procedures. A. Kyle Jones and Alexander S. Pasciak are owners of Fluoroscopic Safety, LLC.« less
Kim, Dongkue; Park, Sangsoo; Jeong, Myung Ho; Ryu, Jeha
2018-02-01
In percutaneous coronary intervention (PCI), cardiologists must study two different X-ray image sources: a fluoroscopic image and an angiogram. Manipulating a guidewire while alternately monitoring the two separate images on separate screens requires a deep understanding of the anatomy of coronary vessels and substantial training. We propose 2D/2D spatiotemporal image registration of the two images in a single image in order to provide cardiologists with enhanced visual guidance in PCI. The proposed 2D/2D spatiotemporal registration method uses a cross-correlation of two ECG series in each image to temporally synchronize two separate images and register an angiographic image onto the fluoroscopic image. A guidewire centerline is then extracted from the fluoroscopic image in real time, and the alignment of the centerline with vessel outlines of the chosen angiographic image is optimized using the iterative closest point algorithm for spatial registration. A proof-of-concept evaluation with a phantom coronary vessel model with engineering students showed an error reduction rate greater than 74% on wrong insertion to nontarget branches compared to the non-registration method and more than 47% reduction in the task completion time in performing guidewire manipulation for very difficult tasks. Evaluation with a small number of experienced doctors shows a potentially significant reduction in both task completion time and error rate for difficult tasks. The total registration time with real procedure X-ray (angiographic and fluoroscopic) images takes [Formula: see text] 60 ms, which is within the fluoroscopic image acquisition rate of 15 Hz. By providing cardiologists with better visual guidance in PCI, the proposed spatiotemporal image registration method is shown to be useful in advancing the guidewire to the coronary vessel branches, especially those difficult to insert into.
Martin, Colin J
2016-06-01
Doses to the eye lenses of clinicians undertaking fluoroscopically guided procedures can exceed the dose annual limit of 20 mSv, so optimisation of radiation protection is essential. Ceiling-suspended shields and disposable radiation absorbing pads can reduce eye dose by factors of 2-7. Lead glasses that shield against exposures from the side can lower doses by 2.5-4.5 times. Training in effective use of protective devices is an essential element in achieving good protection and acceptable eye doses. Effective methods for dose monitoring are required to identify protection issues. Dosemeters worn adjacent to the eye provide the better option for interventional clinicians, but an unprotected dosemeter worn at the neck will give an indication of eye dose that is adequate for most interventional staff. Potential requirements for protective devices and dose monitoring can be determined from risk assessments using generic values for dose linked to examination workload. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Greenbaum, Alissa; Parasher, Gulshan; Demarest, Gerald; Auyang, Edward
2017-05-05
Iatrogenic duodenal injury occurring during laparoscopic cholecystectomy (LC) is managed surgically, though rarely a large, persistent fistula is refractory to surgical interventions. We present the case of a 40-year-old woman transferred to our centre following elective LC for a reported perforated duodenal ulcer. An uncontained leak was found to originate from a 1.5 cm duodenal defect, with no evidence of ulceration. A duodenostomy tube was placed. One month after abdominal closure, the patient continued to have a persistent, large duodenal fistula. A through-the-scope covered oesophageal stent was placed under endoscopic and fluoroscopic guidance. Five weeks later, it was successfully retrieved and no subsequent extravasation of contrast from the duodenum was noted. Unrecognised iatrogenic duodenal injuries sustained during LC can be catastrophic. In cases of massive duodenal defects and high-output biliary fistula uncontrolled after surgical intervention, endoscopic-guided and fluoroscopic-guided placement of a fully covered oesophageal stent may be lifesaving. © BMJ Publishing Group Ltd (unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Galster, M; Guhl, C; Uder, M; Adamus, R
2013-05-01
Efficacy of radiation protection tools for the eye lens dose of the radiologist in fluoroscopic interventions. A patient phantom was exposed using a fluoroscopic system. Dose measurements were made at the eye location of the radiologist using an ionization chamber. The setting followed typical fluoroscopic interventions. The reduction of scattered radiation by the equipment-mounted shielding (undercouch drapes and overcouch top) was evaluated. The ceiling-suspended lead acrylic glass screen was tested in scattered radiation generated by a slab phantom. The protective properties of different lead glass goggles and lead acrylic visors were evaluated by thermoluminescence measurements on a head phantom in the primary beam. The exposition of the lens of about 110 to 550 μSv during radiologic interventions is only slightly reduced by the undercouch drapes. Applying the top in addition to the drapes reduces the lens dose by a factor of 2 for PA projections. In 25°LAO the dose is reduced by a factor between 1.2 and 5. The highest doses were measured for AP angulations furthermore the efficacy of the equipment-mounted shielding is minimal. The ceiling-suspended lead screen reduced scatter by a factor of about 30. The lead glass goggles and visors reduced the lens dose up to a factor of 8 to 10. Depending on the specific design, the tested models are less effective especially for radiation from lateral with cranial angulation of the beam. Occasionally the visors even caused an increase of dose. The exposition of the eye lens can be kept below the new occupational limit recommended by the ICRP if the radiation shielding equipment is used consistently. © Georg Thieme Verlag KG Stuttgart · New York.
CT-guided robotically-assisted infiltration of foot and ankle joints.
Wiewiorski, Martin; Valderrabano, Victor; Kretzschmar, Martin; Rasch, Helmut; Markus, Tanja; Dziergwa, Severine; Kos, Sebastian; Bilecen, Deniz; Jacob, Augustinus Ludwig
2009-01-01
It was our aim to describe a CT-guided robotically-assisted infiltration technique for diagnostic injections in foot and ankle orthopaedics. CT-guided mechatronically-assisted joint infiltration was performed on 16 patients referred to the orthopaedic department for diagnostic foot and ankle assessment. All interventions were performed using an INNOMOTION-assistance device on a multislice CT scanner in an image-guided therapy suite. Successful infiltration was defined as CT localization of contrast media in the target joint. Additionally, pre- and post-interventional VAS pain scores were assessed. All injections (16/16 joints) were technically successful. Contrast media deposit was documented in all targeted joints. Significant relief of pain was noted by all 16 patients (p<0.01). CT-guided robotically-assisted intervention is an exact, reliable and safe application method for diagnostic infiltration of midfoot and hindfoot joints. The high accuracy and feasibility in a clinical environment make it a viable alternative to the commonly used fluoroscopic-guided procedures.
Fluoroscopically Guided Epidural Injections of the Cervical and Lumbar Spine.
Shim, Euddeum; Lee, Joon Woo; Lee, Eugene; Ahn, Joong Mo; Kang, Yusuhn; Kang, Heung Sik
2017-01-01
Advances in imaging and the development of injection techniques have enabled spinal intervention to become an important tool in managing chronic spinal pain. Epidural steroid injection (ESI) is one of the most widely used spinal interventions; it directly delivers drugs into the epidural space to relieve pain originating from degenerative spine disorders-central canal stenoses and neural foraminal stenoses-or disk herniations. Knowledge of the normal anatomy of the epidural space is essential to perform an effective and safe ESI and to recognize possible complications. Although computed tomographic (CT) or combined CT-fluoroscopic guidance has been increasingly used in ESI, conventional fluoroscopic guidance is generally performed. In ESI, drugs are delivered into the epidural space by interlaminar or transforaminal routes in the cervical spine or by interlaminar, transforaminal, or caudal routes in the lumbar spine. Epidurography is usually performed before drug delivery to verify the proper position of the needle in the epidural space. A small amount of contrast agent is injected with fluoroscopic guidance. Familiarity with the findings on a typical "true" epidurogram (demonstrating correct needle placement in the epidural space) permits proper performance of ESI. Findings on "false" epidurograms (demonstrating incorrect needle placement) include muscular staining and evidence of intravascular injection, inadvertent facet joint injection, dural puncture, subdural injection, and intraneural or intradiscal injection. © RSNA, 2016 An earlier incorrect version of this article appeared online. This article was corrected on December 22, 2016.
Loughran, Brendan; Swetadri Vasan, S N; Singh, Vivek; Ionita, Ciprian N; Jain, Amit; Bednarek, Daniel R; Titus, Albert; Rudin, Stephen
2013-03-06
The detectors that are used for endovascular image-guided interventions (EIGI), particularly for neurovascular interventions, do not provide clinicians with adequate visualization to ensure the best possible treatment outcomes. Developing an improved x-ray imaging detector requires the determination of estimated clinical x-ray entrance exposures to the detector. The range of exposures to the detector in clinical studies was found for the three modes of operation: fluoroscopic mode, high frame-rate digital angiographic mode (HD fluoroscopic mode), and DSA mode. Using these estimated detector exposure ranges and available CMOS detector technical specifications, design requirements were developed to pursue a quantum limited, high resolution, dynamic x-ray detector based on a CMOS sensor with 50 μm pixel size. For the proposed MAF-CMOS, the estimated charge collected within the full exposure range was found to be within the estimated full well capacity of the pixels. Expected instrumentation noise for the proposed detector was estimated to be 50-1,300 electrons. Adding a gain stage such as a light image intensifier would minimize the effect of the estimated instrumentation noise on total image noise but may not be necessary to ensure quantum limited detector operation at low exposure levels. A recursive temporal filter may decrease the effective total noise by 2 to 3 times, allowing for the improved signal to noise ratios at the lowest estimated exposures despite consequent loss in temporal resolution. This work can serve as a guide for further development of dynamic x-ray imaging prototypes or improvements for existing dynamic x-ray imaging systems.
Chu, James C.H.; Hsi, Wen Chien; Hubbard, Lincoln; Zhang, Yunkai; Bernard, Damian; Reeder, Pamela; Lopes, Demetrius
2005-01-01
A hospital‐based magnetic guidance system (MGS) was installed to assist a physician in navigating catheters and guide wires during interventional cardiac and neurosurgical procedures. The objective of this study is to examine the performance of this magnetic field‐guided navigation system. Our results show that the system's radiological imaging components produce images with quality similar to that produced by other modern fluoroscopic devices. The system's magnetic navigation components also deflect the wire and catheter tips toward the intended direction. The physician, however, will have to oversteer the wire or catheter when defining the steering angle during the procedure. The MGS could be clinically useful in device navigation deflection and vessel access. PACS numbers: 07.55.Db, 07.85.‐m PMID:16143799
Thaden, Jeremy J; Sanon, Saurabh; Geske, Jeffrey B; Eleid, Mackram F; Nijhof, Niels; Malouf, Joseph F; Rihal, Charanjit S; Bruce, Charles J
2016-06-01
There has been significant growth in the volume and complexity of percutaneous structural heart procedures in the past decade. Increasing procedural complexity and accompanying reliance on multimodality imaging have fueled the development of fusion imaging to facilitate procedural guidance. The first clinically available system capable of echocardiographic and fluoroscopic fusion for real-time guidance of structural heart procedures was approved by the US Food and Drug Administration in 2012. Echocardiographic-fluoroscopic fusion imaging combines the precise catheter and device visualization of fluoroscopy with the soft tissue anatomy and color flow Doppler information afforded by echocardiography in a single image. This allows the interventionalist to perform precise catheter manipulations under fluoroscopy guidance while visualizing critical tissue anatomy provided by echocardiography. However, there are few data available addressing this technology's strengths and limitations in routine clinical practice. The authors provide a critical review of currently available echocardiographic-fluoroscopic fusion imaging for guidance of structural heart interventions to highlight its strengths, limitations, and potential clinical applications and to guide further research into value of this emerging technology. Copyright © 2016 American Society of Echocardiography. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Swetadri Vasan, S. N.; Pope, Liza; Ionita, Ciprian N.; Titus, A. H.; Bednarek, D. R.; Rudin, S.
2013-03-01
A novel dose reduction technique for fluoroscopic interventions involving a combination of a material x-ray region of interest (ROI) attenuator and spatially different, temporally variable ROI temporal recursive filter, was used to guide the catheter to the ROI in three live animal studies, two involving rabbits and one involving a sheep. In the two rabbit studies presented , a catheter was guided to the entrance of the carotid artery. With the added ROI attenuator the image under the high attenuation region is very noisy. By using temporal filtering with a filter weight of 0.6 on previous frames, the noise is reduced. In the sheep study the catheter was guided to the descending aorta of the animal. The sheep offered a relatively higher attenuation to the incident x-rays and thus a higher temporal filter weight of 0.8 on previous frames was used during the procedure to reduce the noise to levels acceptable by the interventionalist. The image sequences from both studies show that significant dose reduction of 5-6 times can be achieved with acceptable image quality outside the ROI by using the above mentioned technique. Even though the temporal filter weighting outside the ROI is higher, the consequent lag does not prevent perception of catheter movement.
Yuenyongviwat, Varah; Tuntarattanapong, Pakjai; Tangtrakulwanich, Boonsin
2016-01-11
Internal fixation is one treatment for femoral neck fracture. Some devices and techniques reported improved accuracy and decreased fluoroscopic time. However, these are not widely used nowadays due to the lack of available special instruments and techniques. To improve the surgical procedure, the authors designed a new adjustable drill guide and tested the efficacy of the device. The authors developed a new adjustable drill guide for cannulated screw guide wire insertion for multiple screw fixation. Eight orthopaedic surgeons performed the experimental study to evaluate the efficacy of this device. Each surgeon performed guide wire insertion for multiple screw fixation in six synthetic femurs: three times with the new device and three times with the conventional technique. The fluoroscopic time, operative time and surgeon satisfaction were evaluated. In the operations with the new adjustable drill guide, the fluoroscopic and operative times were significantly lower than the operations with the conventional technique (p < 0.05). The mean score for the level of satisfaction of this device was also statistically significantly better (p = 0.02) than the conventional technique. The fluoroscopic and operative times with the new adjustable drill guide were reduced for multiple screw fixation of femoral neck fracture and the satisfaction of the surgeons was good.
Three-dimensional curvilinear device reconstruction from two fluoroscopic views
NASA Astrophysics Data System (ADS)
Delmas, Charlotte; Berger, Marie-Odile; Kerrien, Erwan; Riddell, Cyril; Trousset, Yves; Anxionnat, René; Bracard, Serge
2015-03-01
In interventional radiology, navigating devices under the sole guidance of fluoroscopic images inside a complex architecture of tortuous and narrow vessels like the cerebral vascular tree is a difficult task. Visualizing the device in 3D could facilitate this navigation. For curvilinear devices such as guide-wires and catheters, a 3D reconstruction may be achieved using two simultaneous fluoroscopic views, as available on a biplane acquisition system. The purpose of this paper is to present a new automatic three-dimensional curve reconstruction method that has the potential to reconstruct complex 3D curves and does not require a perfect segmentation of the endovascular device. Using epipolar geometry, our algorithm translates the point correspondence problem into a segment correspondence problem. Candidate 3D curves can be formed and evaluated independently after identifying all possible combinations of compatible 3D segments. Correspondence is then inherently solved by looking in 3D space for the most coherent curve in terms of continuity and curvature. This problem can be cast into a graph problem where the most coherent curve corresponds to the shortest path of a weighted graph. We present quantitative results of curve reconstructions performed from numerically simulated projections of tortuous 3D curves extracted from cerebral vascular trees affected with brain arteriovenous malformations as well as fluoroscopic image pairs of a guide-wire from both phantom and clinical sets. Our method was able to select the correct 3D segments in 97.5% of simulated cases thus demonstrating its ability to handle complex 3D curves and can deal with imperfect 2D segmentation.
Praveen, Alampath; Sreekumar, Karumathil Pullara; Nazar, Puthukudiyil Kader; Moorthy, Srikanth
2012-04-01
Thoracic duct embolization (TDE) is an established radiological interventional procedure for thoracic duct injuries. Traditionally, it is done under fluoroscopic guidance after opacifying the thoracic duct with bipedal lymphangiography. We describe our experience in usinga heavily T2W sequence for guiding thoracic duct puncture and direct injection of glue through the puncture needle without cannulating the duct.
Santos, William S; Belinato, Walmir; Perini, Ana P; Caldas, Linda V E; Galeano, Diego C; Santos, Carla J; Neves, Lucio P
2018-01-01
In this study we evaluated the occupational exposures during an abdominal fluoroscopically guided interventional radiology procedure. We investigated the relation between the Body Mass Index (BMI), of the patient, and the conversion coefficient values (CC) for a set of dosimetric quantities, used to assess the exposure risks of medical radiation workers. The study was performed using a set of male and female virtual anthropomorphic phantoms, of different body weights and sizes. In addition to these phantoms, a female and a male phantom, named FASH3 and MASH3 (reference virtual anthropomorphic phantoms), were also used to represent the medical radiation workers. The CC values, obtained as a function of the dose area product, were calculated for 87 exposure scenarios. In each exposure scenario, three phantoms, implemented in the MCNPX 2.7.0 code, were simultaneously used. These phantoms were utilized to represent a patient and medical radiation workers. The results showed that increasing the BMI of the patient, adjusted for each patient protocol, the CC values for medical radiation workers decrease. It is important to note that these results were obtained with fixed exposure parameters. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
Navigation for fluoroscopy-guided cryo-balloon ablation procedures of atrial fibrillation
NASA Astrophysics Data System (ADS)
Bourier, Felix; Brost, Alexander; Kleinoeder, Andreas; Kurzendorfer, Tanja; Koch, Martin; Kiraly, Attila; Schneider, Hans-Juergen; Hornegger, Joachim; Strobel, Norbert; Kurzidim, Klaus
2012-02-01
Atrial fibrillation (AFib), the most common arrhythmia, has been identified as a major cause of stroke. The current standard in interventional treatment of AFib is the pulmonary vein isolation (PVI). PVI is guided by fluoroscopy or non-fluoroscopic electro-anatomic mapping systems (EAMS). Either classic point-to-point radio-frequency (RF)- catheter ablation or so-called single-shot-devices like cryo-balloons are used to achieve electrically isolation of the pulmonary veins and the left atrium (LA). Fluoroscopy-based systems render overlay images from pre-operative 3-D data sets which are then merged with fluoroscopic imaging, thereby adding detailed 3-D information to conventional fluoroscopy. EAMS provide tracking and visualization of RF catheters by means of electro-magnetic tracking. Unfortunately, current navigation systems, fluoroscopy-based or EAMS, do not provide tools to localize and visualize single shot devices like cryo-balloon catheters in 3-D. We present a prototype software for fluoroscopy-guided ablation procedures that is capable of superimposing 3-D datasets as well as reconstructing cyro-balloon catheters in 3-D. The 3-D cyro-balloon reconstruction was evaluated on 9 clinical data sets, yielded a reprojected 2-D error of 1.72 mm +/- 1.02 mm.
Engel, Andrew; Rappard, George; King, Wade; Kennedy, David J
2016-04-01
To determine the effectiveness and risks of fluoroscopically-guided cervical medial branch thermal radiofrequency neurotomy (CMBTRFN) for treating chronic neck pain of zygapophysial joint origin. Systematic review of the literature with comprehensive analysis of the published data. Four reviewers formally trained in evidence-based medicine searched the literature on CMBTRFN. Each assessed the methodologies of studies found and appraised the quality of evidence presented. The primary outcomes assessed were 100% relief of pain 6 and 12 months after treatment. Other outcomes were noted if reported. The evidence was evaluated in accordance with the Grades of Recommendation, Assessment, Development, and Evaluation (GRADE) system. The searches yielded eight primary publications on the effectiveness of the procedure. The evidence shows a majority of patients were pain free at 6 months and over a third were pain free at 1 year. The number needed to treat for complete pain relief at 6 months is 2. The evidence of effectiveness is of high quality according to the GRADE system. Twelve papers were found reporting unwanted effects, most of which are minor and temporary. No serious complications have ever been reported from procedures performed according to the published guidelines. The evidence of risks is of low quality according to the GRADE system. If performed as described in the International Spine Intervention Society Guidelines, fluoroscopically-guided CMBTRFN is effective for abolishing zygapophysial joint pain and carries only minor risks. © 2015 American Academy of Pain Medicine. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Shellikeri, Sphoorti; Setser, Randolph M; Hwang, Tiffany J; Srinivasan, Abhay; Krishnamurthy, Ganesh; Vatsky, Seth; Girard, Erin; Zhu, Xiaowei; Keller, Marc S; Cahill, Anne Marie
2017-07-01
Navigational software provides real-time fluoroscopic needle guidance for percutaneous procedures in the Interventional Radiology (IR) suite. We describe our experience with navigational software for pediatric percutaneous bone biopsies in the IR suite and compare technical success, diagnostic accuracy, radiation dose and procedure time with that of CT-guided biopsies. Pediatric bone biopsies performed using navigational software (Syngo iGuide, Siemens Healthcare) from 2011 to 2016 were prospectively included and anatomically matched CT-guided bone biopsies from 2008 to 2016 were retrospectively reviewed with institutional review board approval. C-arm CT protocols used for navigational software-assisted cases included institution-developed low-dose (0.1/0.17 μGy/projection), regular-dose (0.36 μGy/projection), or a combination of low-dose/regular-dose protocols. Estimated effective radiation dose and procedure times were compared between software-assisted and CT-guided biopsies. Twenty-six patients (15 male; mean age: 10 years) underwent software-assisted biopsies (15 pelvic, 7 lumbar and 4 lower extremity) and 33 patients (13 male; mean age: 9 years) underwent CT-guided biopsies (22 pelvic, 7 lumbar and 4 lower extremity). Both modality biopsies resulted in a 100% technical success rate. Twenty-five of 26 (96%) software-assisted and 29/33 (88%) CT-guided biopsies were diagnostic. Overall, the effective radiation dose was significantly lower in software-assisted than CT-guided cases (3.0±3.4 vs. 6.6±7.7 mSv, P=0.02). The effective dose difference was most dramatic in software-assisted cases using low-dose C-arm CT (1.2±1.8 vs. 6.6±7.7 mSv, P=0.001) or combined low-dose/regular-dose C-arm CT (1.9±2.4 vs. 6.6±7.7 mSv, P=0.04), whereas effective dose was comparable in software-assisted cases using regular-dose C-arm CT (6.0±3.5 vs. 6.6±7.7 mSv, P=0.7). Mean procedure time was significantly lower for software-assisted cases (91±54 vs. 141±68 min, P=0.005). In our experience, navigational software technology in the IR suite is a promising alternative to CT guidance for pediatric bone biopsies providing comparable technical success and diagnostic accuracy with lower radiation dose and procedure time, in addition to providing real-time fluoroscopic needle guidance.
Preclinical Feasibility of a Technology Framework for MRI-guided Iliac Angioplasty
Rube, Martin A.; Fernandez-Gutierrez, Fabiola; Cox, Benjamin F.; Holbrook, Andrew B.; Houston, J. Graeme; White, Richard D.; McLeod, Helen; Fatahi, Mahsa; Melzer, Andreas
2015-01-01
Purpose Interventional MRI has significant potential for image guidance of iliac angioplasty and related vascular procedures. A technology framework with in-room image display, control, communication and MRI-guided intervention techniques was designed and tested for its potential to provide safe, fast and efficient MRI-guided angioplasty of the iliac arteries. Methods A 1.5T MRI scanner was adapted for interactive imaging during endovascular procedures using new or modified interventional devices such as guidewires and catheters. A perfused vascular phantom was used for testing. Pre-, intra- and post-procedural visualization and measurement of vascular morphology and flow was implemented. A detailed analysis of X-Ray fluoroscopic angiography workflow was conducted and applied. Two interventional radiologists and one physician in training performed 39 procedures. All procedures were timed and analyzed. Results MRI-guided iliac angioplasty procedures were successfully performed with progressive adaptation of techniques and workflow. The workflow, setup and protocol enabled a reduction in table time for a dedicated MRI-guided procedure to 6 min 33 s with a mean procedure time of 9 min 2 s, comparable to the mean procedure time of 8 min 42 s for the standard X-Ray guided procedure. Conclusions MRI-guided iliac vascular interventions were found to be feasible and practical using this framework and optimized workflow. In particular the real-time flow analysis was found to be helpful for pre- and post-interventional assessments. Design optimization of the catheters and in vivo experiments are required before clinical evaluation. PMID:25102933
Heilmaier, Christina; Kara, Levent; Zuber, Niklaus; Berthold, Christian; Weishaupt, Dominik
2016-04-01
To determine the effect on patient radiation exposure of the combined use of a patient dose monitoring system and real-time occupational dose monitoring during fluoroscopically guided interventions (FGIs). Patient radiation exposure, in terms of the kerma area product (KAP; Gy ∙ cm(2)), was measured in period 1 with a patient dose monitoring system, and a real-time occupational dose monitoring system was additionally applied in period 2. Mean/median KAP in 19 different types of FGIs was analyzed in both periods for two experienced interventional radiologists combined as well as individually. Patient dose and occupational dose were correlated, applying Pearson and Spearman correlation coefficients. Although FGIs were similar in numbers and types over both periods, a substantial decrease was found for period 2 in total mean ± SD/median KAP for both operators together (period 1, 47 Gy ∙ cm(2) ± 67/41 Gy ∙ cm(2); period 2, 37 Gy ∙ cm(2) ± 69/34 Gy ∙ cm(2)) as well as for each individual operator (for all, P < .05). Overall, KAP declined considerably in 15 of 19 types of FGIs in period 2. Mean accumulated dose per intervention was 4.6 µSv, and mean dose rate was 0.24 mSv/h. There was a strong positive correlation between patient and occupational dose (r = 0.88). Combined use of a patient dose monitoring system and a real-time occupational dose monitoring system in FGIs significantly lessens patient and operator doses. Copyright © 2016 SIR. Published by Elsevier Inc. All rights reserved.
Praveen, Alampath; Sreekumar, Karumathil Pullara; Nazar, Puthukudiyil Kader; Moorthy, Srikanth
2012-01-01
Thoracic duct embolization (TDE) is an established radiological interventional procedure for thoracic duct injuries. Traditionally, it is done under fluoroscopic guidance after opacifying the thoracic duct with bipedal lymphangiography. We describe our experience in usinga heavily T2W sequence for guiding thoracic duct puncture and direct injection of glue through the puncture needle without cannulating the duct. PMID:23162248
NASA Astrophysics Data System (ADS)
Mefleh, Fuad N.; Baker, G. Hamilton; Kwartowitz, David M.
2014-03-01
In our previous work we presented a novel image-guided surgery (IGS) system, Kit for Navigation by Image Focused Exploration (KNIFE).1,2 KNIFE has been demonstrated to be effective in guiding mock clinical procedures with the tip of an electromagnetically tracked catheter overlaid onto a pre-captured bi-plane fluoroscopic loop. Representation of the catheter in KNIFE differs greatly from what is captured by the fluoroscope, due to distortions and other properties of fluoroscopic images. When imaged by a fluoroscope, catheters can be visualized due to the inclusion of radiopaque materials (i.e. Bi, Ba, W) in the polymer blend.3 However, in KNIFE catheter location is determined using a single tracking seed located in the catheter tip that is represented as a single point overlaid on pre-captured fluoroscopic images. To bridge the gap in catheter representation between KNIFE and traditional methods we constructed a catheter with five tracking seeds positioned along the distal 70 mm of the catheter. We have currently investigated the use of four spline interpolation methods for estimation of true catheter shape and have assesed the error in their estimation of true catheter shape. In this work we present a method for the evaluation of interpolation algorithms with respect to catheter shape determination.
Song, Min; Song, Ho-Young; Kim, Jin Hyoung; Park, Jung-Hoon; Jung, Hwoon-Yong; Kim, Jong-Hoon; Kim, Sung-Bae
2011-09-01
To retrospectively evaluate the incidence, predictive factors, and interventional management of food impaction after expandable metallic stent placement in patients with obstruction of the esophagus or upper gastrointestinal tract caused by benign or malignant disease. Between March 1993 and March 2010, 1,360 patients (1,029 men, 331 women; age range, 21-89 y; mean age, 61 y) underwent fluoroscopically guided stent placement for dysphagia caused by esophageal or gastrointestinal tract strictures. Five types of covered expandable metal stents were used, including four types of esophageal stents (types A-D) and one type of gastroduodenal stent (type E), with types A, B, C, D, and E stents used in 180, 60, 90, 432, and 598 patients, respectively. Multivariate analysis was performed to evaluate factors predictive of food impaction. Food impaction occurred in 41 of 1,360 patients (3.0%). The food impaction rates for types A, B, C, D, and E stents were 0.6%, 1.7%, 1.1%, 3.2%, and 4.0%, respectively. Multivariate analysis showed that stent length was an independent predictor of food impaction (odds ratio, 0.839; P = .012). Of the 41 patients with food impaction, 23 underwent endoscopic management, 12 underwent fluoroscopically guided management, and six did not require management because impacted food spontaneously passed through the stent. The overall food impaction rate was 3.0%, with multiple logistic regression analysis showing that shorter stent length was the only significant predictor of food impaction. Food impaction can be managed by endoscopic or fluoroscopically guided removal or placement of a second stent. Copyright © 2011 SIR. Published by Elsevier Inc. All rights reserved.
Rutten, Matthieu J C M; Collins, James M P; Maresch, Bas J; Smeets, Jacques H J M; Janssen, Caroline M M; Kiemeney, Lambertus A L M; Jager, Gerrit J
2009-03-01
To assess the variability in accuracy of contrast media introduction, leakage, required time and patient discomfort in four different centres, each using a different image-guided glenohumeral injection technique. Each centre included 25 consecutive patients. The ultrasound-guided anterior (USa) and posterior approach (USp), fluoroscopic-guided anterior (FLa) and posterior (FLp) approach were used. Number of injection attempts, effect of contrast leakage on diagnostic quality, and total room, radiologist and procedure times were measured. Pain was documented with a visual analogue scale (VAS) pain score. Access to the joint was achieved in all patients. A successful first attempt significantly occurred more often with US (94%) than with fluoroscopic guidance (72%). Leakage of contrast medium did not cause interpretative difficulties. With US guidance mean room, procedure and radiologist times were significantly shorter (p < 0.001). The USa approach was rated with the lowest pre- and post-injection VAS scores. The four image-guided injection techniques are successful in injection of contrast material into the glenohumeral joint. US-guided injections and especially the anterior approach are significantly less time consuming, more successful on the first attempt, cause less patient discomfort and obviate the need for radiation and iodine contrast.
2010-02-01
subsequent research has yielded additional in- sights. This review is a consensus report of current scien- tifi c data. Expected skin reactions for an...table has been cited and reproduced Essentials The minimum radiation dose n causing a specifi c type of reac- tion in the skin or hair is best...expressed in terms of a range of doses, rather than a single threshold dose. The times of onset and resolution n of specifi c radiation injuries
Image Guidance Technologies for Interventional Pain Procedures: Ultrasound, Fluoroscopy, and CT.
Wang, Dajie
2018-01-26
Chronic pain is a common medical condition. Patients who suffer uncontrolled chronic pain may require interventions including spinal injections and various nerve blocks. Interventional procedures have evolved and improved over time since epidural injection was first introduced for low back pain and sciatica in 1901. One of the major contributors in the improvement of these interventions is the advancement of imaging guidance technologies. The utilization of image guidance has dramatically improved the accuracy and safety of these interventions. The first image guidance technology adopted by pain specialists was fluoroscopy. This was followed by CT and ultrasound. Fluoroscopy can be used to visualize bony structures of the spine. It is still the most commonly used guidance technology in spinal injections. In the recent years, ultrasound guidance has been increasingly adopted by interventionists to perform various injections. Because its ability to visualize soft tissue, vessels, and nerves, this guidance technology appears to be a better option than fluoroscopy for interventions including SGB and celiac plexus blocks, when visualization of the vessels may prevent intravascular injection. The current evidence indicates the efficacies of these interventions are similar between ultrasound guidance and fluoroscopy guidance for SGB and celiac plexus blocks. For facet injections and interlaminar epidural steroid injections, it is important to visualize bony structures in order to perform these procedures accurately and safely. It is worth noting that facet joint injections can be done under ultrasound guidance with equivalent efficacy to fluoroscopic guidance. However, obese patients may present challenge for ultrasound guidance due to its poor visualization of deep anatomical structures. Regarding transforaminal epidural steroid injections, there are limited evidence to support that ultrasound guidance technology has equivalent efficacy and less complications comparing to fluoroscopy. However, further studies are required to prove the efficacy of ultrasound-guided transforaminal epidural injections. SI joint is unique due to its multiplanar orientation, irregular joint gap, partial ankylosis, and thick dorsal and interosseous ligament. Therefore, it can be difficult to access the joint space with fluoroscopic guidance and ultrasound guidance. CT scan, with its cross-sectional images, can identify posterior joint gap, is most likely the best guidance technology for this intervention. Intercostal nerves lie in the subcostal grove close to the plural space. Significant risk of pneumothorax is associated with intercostal blocks. Ultrasound can provide visualization of ribs and pleura. Therefore, it may improve the accuracy of the injection and reduce the risk of pneumothorax. At present time, most pain specialists are familiar with fluoroscopic guidance techniques, and fluoroscopic machines are readily available in the pain clinics. In the contrast, CT guidance can only be performed in specially equipped facilities. Ultrasound machine is generally portable and inexpensive in comparison to CT scanner and fluoroscopic machine. As pain specialists continue to improve their patient care, ultrasound and CT guidance will undoubtedly be incorporated more into the pain management practice. This review is based on a paucity of clinical evidence to compare these guidance technologies; clearly, more clinical studies is needed to further elucidate the pro and cons of each guidance method for various pain management interventions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sutcliffe, James, E-mail: jasutcliffe@gmail.com; Wigham, Andrew, E-mail: a.wigham@doctors.org.uk; Mceniff, Niall, E-mail: nmceniff@stjames.ie
PurposeSurgical Gastrostomy has been around since the 19th century but in 1980 the first successful percutaneous endoscopic gastrostomy was reported. A year later the first successful percutaneous gastrostomy was performed using fluoroscopic guidance. The technique for percutaneous insertion and the equipment used has been refined since then and it is now considered the gold standard for gastrostomy insertion. Here we present guidelines for image-guided enteral feeding tubes in adults.Material and MethodWe performed a review and analysis of the scientific literature, other national and international guidelines and expert opinion.ResultsStudies have shown fluoroscopic techniques have consistently higher success rates with lower ratesmore » of major complications than endoscopic techniques. However, the Achilles' heel of many fluoroscopic techniques is the requirement for smaller gastrostomy tube sizes resulting in them being more prone to blockages and thus requiring further intervention.ConclusionRadiological feeding tube insertion is a safe and effective procedure. Success rates are higher, and complication rates lower than PEG or surgical gastrostomy tube placement and innovative techniques for gastric and jejunal access mean that there are very few cases in which RIG is not possible. The principal weakness of radiologically inserted gastrostomies is the limitiation on tube size which leads to a higher rate of tube blockage. Per-oral image-guided gastrostomies have to an extent addressed this but have not been popularised. Currently many centres still consider endoscopic gastrostomies as the first line unless patients are too unwell to undergo this procedure or previous attempts have failed, in which case radioloically inserted gastrostomies are the technique of choice.« less
Percutaneous foot joint needle placement using a C-arm flat-panel detector CT.
Wiewiorski, Martin; Takes, Martin Thanh Long; Valderrabano, Victor; Jacob, Augustinus Ludwig
2012-03-01
Image guidance is valuable for diagnostic injections in foot orthopaedics. Flat-detector computed tomography (FD-CT) was implemented using a C-arm, and the system was tested for needle guidance in foot joint injections. FD-CT-guided joint infiltration was performed in 6 patients referred from the orthopaedic department for diagnostic foot injections. All interventions were performed utilising a flat-panel fluoroscopy system utilising specialised image guidance and planning software. Successful infiltration was defined by localisation of contrast media depot in the targeted joint. The pre- and post-interventional numeric analogue scale (NAS) pain score was assessed. All injections were technically successful. Contrast media deposit was documented in all targeted joints. Significant relief of symptoms was noted by all 6 participants. FD-CT-guided joint infiltration is a feasible method for diagnostic infiltration of midfoot and hindfoot joints. The FD-CT approach may become an alternative to commonly used 2D-fluoroscopically guidance.
Fluoroscopic tumor tracking for image-guided lung cancer radiotherapy
NASA Astrophysics Data System (ADS)
Lin, Tong; Cerviño, Laura I.; Tang, Xiaoli; Vasconcelos, Nuno; Jiang, Steve B.
2009-02-01
Accurate lung tumor tracking in real time is a keystone to image-guided radiotherapy of lung cancers. Existing lung tumor tracking approaches can be roughly grouped into three categories: (1) deriving tumor position from external surrogates; (2) tracking implanted fiducial markers fluoroscopically or electromagnetically; (3) fluoroscopically tracking lung tumor without implanted fiducial markers. The first approach suffers from insufficient accuracy, while the second may not be widely accepted due to the risk of pneumothorax. Previous studies in fluoroscopic markerless tracking are mainly based on template matching methods, which may fail when the tumor boundary is unclear in fluoroscopic images. In this paper we propose a novel markerless tumor tracking algorithm, which employs the correlation between the tumor position and surrogate anatomic features in the image. The positions of the surrogate features are not directly tracked; instead, we use principal component analysis of regions of interest containing them to obtain parametric representations of their motion patterns. Then, the tumor position can be predicted from the parametric representations of surrogates through regression. Four regression methods were tested in this study: linear and two-degree polynomial regression, artificial neural network (ANN) and support vector machine (SVM). The experimental results based on fluoroscopic sequences of ten lung cancer patients demonstrate a mean tracking error of 2.1 pixels and a maximum error at a 95% confidence level of 4.6 pixels (pixel size is about 0.5 mm) for the proposed tracking algorithm.
C-arm cone beam computed tomography needle path overlay for fluoroscopic guided vertebroplasty.
Tam, Alda L; Mohamed, Ashraf; Pfister, Marcus; Chinndurai, Ponraj; Rohm, Esther; Hall, Andrew F; Wallace, Michael J
2010-05-01
Retrospective review. To report our early clinical experience using C-arm cone beam computed tomography (C-arm CBCT) with fluoroscopic overlay for needle guidance during vertebroplasty. C-arm CBCT is advanced three-dimensional (3-D) imaging technology that is currently available on state-of-the-art flat panel based angiography systems. The imaging information provided by C-arm CBCT allows for the acquisition and reconstruction of "CT-like" images in flat panel based angiography/interventional suites. As part of the evolution of this technology, enhancements allowing the overlay of cross-sectional imaging information can now be integrated with real time fluoroscopy. We report our early clinical experience with C-arm CBCT with fluoroscopic overlay for needle guidance during vertebroplasty. This is a retrospective review of 10 consecutive oncology patients who underwent vertebroplasty of 13 vertebral levels using C-arm CBCT with fluoroscopic overlay for needle guidance from November 2007 to December 2008. Procedural data including vertebral level, approach (transpedicular vs. extrapedicular), access (bilateral vs. unilateral) and complications were recorded. Technical success with the overlay technology was assessed based on accuracy which consisted of 4 measured parameters: distance from target to needle tip, distance from planned path to needle tip, distance from midline to needle tip, and distance from the anterior 1/3 of the vertebral body to needle tip. Success within each parameter required that the distance between the needle tip and parameter being evaluated be no more than 5 mm on multiplanar CBCT or fluoroscopy. Imaging data for 12 vertebral levels was available for review. All vertebral levels were treated using unilateral access and 9 levels were treated with an extrapedicular approach. Technical success rates were 92% for both distance from planned path and distance from midline to final needle tip, 100% when distance from needle tip to the anterior 1/3 border of the vertebral body was measured, and 75% when distance from target to needle tip was measured. There were no major complications. Minor complications consisted of 3 cases (25%) of cement extravasation. C-arm CBCT with needle path overlay for fluoroscopic guided vertebroplasty is feasible and allows for reliable unilateral therapy of both lumbar and thoracic vertebral bodies. Extrapedicular approaches were performed safely and with good accuracy of reaching the targets.
MacVicar, John; Kreiner, D Scott; Duszynski, Belinda; Kennedy, David J
2017-11-01
To provide an overview of a multisociety effort to formulate appropriate use criteria for image-guided injections and radiofrequency procedures in the diagnosis and treatment of sacroiliac joint and posterior sacroiliac complex pain. The Spine Intervention Society convened a multisociety effort to guide physicians and define for payers the appropriate use of image-guided injections and radiofrequency procedures. An evidence panel was established to write systematic reviews, define key terms and assumptions, and develop clinical scenarios to be addressed. The rating panel considered the evidence presented in the systematic reviews, carefully reviewed the definitions and assumptions, and rated the clinical scenarios. Final median ratings, in combination with the level of agreement, determined the final ratings for the appropriate use of sacroiliac injections and radiofrequency neurotomy. More than 10,000 scenarios were addressed in the appropriate use criteria and are housed within five modules in the portal, available on the Spine Intervention Society website: Module 1: Clinical Indications and Imaging; Module 2: Anticoagulants; Module 3: Timing of Injections; Module 4: Number of Injections; and Module 5: Lateral Branch Radiofrequency Neurotomy. Within several of these modules, several issues of interest are identified and discussed. Physicians and payers can access the appropriate use criteria portal on the Spine Intervention Society's website and select specific clinical indications for a particular patient in order to learn more about the appropriateness of the intervention(s) under consideration. © 2017 American Academy of Pain Medicine. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com
Wunderle, Kevin A; Rakowski, Joseph T; Dong, Frank F
2016-05-08
The first goal of this study was to investigate the accuracy of the displayed reference plane air kerma (Ka,r) or air kerma-area product (Pk,a) over a broad spectrum of X-ray beam qualities on clinically used interventional fluoroscopes incorporating air kerma-area product meters (KAP meters) to measure X-ray output. The second goal was to investigate the accuracy of a correction coefficient (CC) determined at a single beam quality and applied to the measured Ka,r over a broad spectrum of beam qualities. Eleven state-of-the-art interventional fluoroscopes were evaluated, consisting of eight Siemens Artis zee and Artis Q systems and three Philips Allura FD systems. A separate calibrated 60 cc ionization chamber (external chamber) was used to determine the accuracy of the KAP meter over a broad range of clinically used beam qualities. For typical adult beam qualities, applying a single CC deter-mined at 100 kVp with copper (Cu) in the beam resulted in a deviation of < 5% due to beam quality variation. This result indicates that applying a CC determined using The American Association of Physicists in Medicine Task Group 190 protocol or a similar protocol provides very good accuracy as compared to the allowed ± 35% deviation of the KAP meter in this limited beam quality range. For interventional fluoroscopes dedicated to or routinely used to perform pediatric interventions, using a CC established with a low kVp (~ 55-60 kVp) and large amount of Cu filtration (~ 0.6-0.9 mm) may result in greater accuracy as compared to using the 100 kVp values. KAP meter responses indicate that fluoroscope vendors are likely normalizing or otherwise influencing the KAP meter output data. Although this may provide improved accuracy in some instances, there is the potential for large discrete errors to occur, and these errors may be difficult to identify.
X-ray and optical stereo-based 3D sensor fusion system for image-guided neurosurgery.
Kim, Duk Nyeon; Chae, You Seong; Kim, Min Young
2016-04-01
In neurosurgery, an image-guided operation is performed to confirm that the surgical instruments reach the exact lesion position. Among the multiple imaging modalities, an X-ray fluoroscope mounted on C- or O-arm is widely used for monitoring the position of surgical instruments and the target position of the patient. However, frequently used fluoroscopy can result in relatively high radiation doses, particularly for complex interventional procedures. The proposed system can reduce radiation exposure and provide the accurate three-dimensional (3D) position information of surgical instruments and the target position. X-ray and optical stereo vision systems have been proposed for the C- or O-arm. Two subsystems have same optical axis and are calibrated simultaneously. This provides easy augmentation of the camera image and the X-ray image. Further, the 3D measurement of both systems can be defined in a common coordinate space. The proposed dual stereoscopic imaging system is designed and implemented for mounting on an O-arm. The calibration error of the 3D coordinates of the optical stereo and X-ray stereo is within 0.1 mm in terms of the mean and the standard deviation. Further, image augmentation with the camera image and the X-ray image using an artificial skull phantom is achieved. As the developed dual stereoscopic imaging system provides 3D coordinates of the point of interest in both optical images and fluoroscopic images, it can be used by surgeons to confirm the position of surgical instruments in a 3D space with minimum radiation exposure and to verify whether the instruments reach the surgical target observed in fluoroscopic images.
Kelekis, Alexios; Filippiadis, Dimitrios K; Velonakis, Georgios; Martin, Jean-Baptist; Oikonomopoulos, Nikolaos; Brountzos, Elias; Kelekis, Nikolaos
2014-01-01
Transforaminal infiltrations in the cervical spine are governed by a higher rate of vascular puncture than in the lumbar spine. The purpose of our study is to assess the safety and efficacy of percutaneous, fluoroscopically guided nerve root infiltrations in cases of cervical radiculopathy. An indirect postero-lateral approach was performed through the ipsilateral facet joint. During the last 2 years, 25 patients experiencing cervical radiculopathy underwent percutaneous, fluoroscopically guided nerve root infiltrations by means of an indirect postero-lateral approach through the ipsilateral facet joint. The intra-articular position of the needle (22-gauge spinal needle) was fluoroscopically verified after injection of a small amount of contrast medium which also verified dispersion of the contrast medium periradicularly and in the epidural space. Then a mixture of long-acting glucocorticosteroid diluted in normal saline (1.5/1 mL) was injected intra-articularly. A questionnaire with a Numeric Visual Scale (NVS) scale helped assess pain relief, life quality, and mobility improvement. A mean of 2.3 sessions was performed in the patients of our study. In the vast majority of our patients 19/25 (76%), the second infiltration was performed within 7-10 days of the first one. Comparing the pain scores prior (mean value 8.80 ± 1.080 NVS units) and after (mean value 1.84 ± 1.405 NVS units), there was a mean decrease of 6.96 ± 1.695 NVS units [median value 7 NVS units (P < 0.001) in terms of pain reduction, effect upon mobility, and life quality. There were no clinically significant complications noted in our study. Fluoroscopically guided transforaminal infiltrations through the ipsilateral facet joint seem to be a feasible, efficacious, and safe approach for the treatment of patients with cervical radiculopathy. This approach facilitates needle placement and minimizes risk of complications.
Fluoroscopically Guided Peritendinous Corticosteroid Injection for Proximal Hamstring Tendinopathy
Nicholson, Luke T.; DiSegna, Steven; Newman, Joel S.; Miller, Suzanne L.
2014-01-01
Background: Proximal hamstring tendinopathy is an uncommon but debilitating cause of posterior thigh pain in athletes subjected to repetitive eccentric hamstring contraction, such as runners. Minimal data exist evaluating treatment options for proximal hamstring tendinopathy. Purpose: This retrospective study evaluates the effectiveness of fluoroscopically guided corticosteroid injections in treating proximal hamstring tendinopathy. Study Design: Case series; Level of evidence, 4. Methods: Eighteen athletes with 22 cases of magnetic resonance imaging–confirmed proximal hamstring tendinopathy were treated with corticosteroid injection and later contacted to evaluate the efficacy of the injection with the use of a questionnaire. Results: The visual analog score decreased from 7.22 preinjection to 3.94 postinjection (P < .001), level of athletic participation increased from 28.76% to 68.82% (P < .001) at a mean follow-up of 21 months, and 38.8% of patients experienced complete resolution at a mean follow-up of 24.8 months. The mean lower extremity function score at the time of follow-up was 60. Conclusion: A trial of fluoroscopically guided corticosteroid injection is warranted in patients presenting with symptoms of proximal hamstring tendinopathy refractory to conservative therapy. PMID:26535310
Nicholson, Luke T; DiSegna, Steven; Newman, Joel S; Miller, Suzanne L
2014-03-01
Proximal hamstring tendinopathy is an uncommon but debilitating cause of posterior thigh pain in athletes subjected to repetitive eccentric hamstring contraction, such as runners. Minimal data exist evaluating treatment options for proximal hamstring tendinopathy. This retrospective study evaluates the effectiveness of fluoroscopically guided corticosteroid injections in treating proximal hamstring tendinopathy. Case series; Level of evidence, 4. Eighteen athletes with 22 cases of magnetic resonance imaging-confirmed proximal hamstring tendinopathy were treated with corticosteroid injection and later contacted to evaluate the efficacy of the injection with the use of a questionnaire. The visual analog score decreased from 7.22 preinjection to 3.94 postinjection (P < .001), level of athletic participation increased from 28.76% to 68.82% (P < .001) at a mean follow-up of 21 months, and 38.8% of patients experienced complete resolution at a mean follow-up of 24.8 months. The mean lower extremity function score at the time of follow-up was 60. A trial of fluoroscopically guided corticosteroid injection is warranted in patients presenting with symptoms of proximal hamstring tendinopathy refractory to conservative therapy.
ICRP special radiation protection issues in interventional radiology, digital and cardiac imaging.
Vano, E; Faulkner, K
2005-01-01
The International Commission on Radiological Protection (ICRP) has published two reports giving recommendations dealing with the avoidance of deterministic injuries in interventional radiology and the management of patient dose in digital radiology in 2001 and 2004, respectively. Another document, on radiation protection for cardiologists performing fluoroscopically guided procedures, will be produced during 2005. This paper highlights some of the topics of the published reports, their relevance to European legislation on medical exposures and the importance of radiation protection research in underpinning the ICRP task groups' work in to producing these documents. It is also anticipated that the results, obtained in the cardiology work package of the European research project, will be used in the new document on radiation protection for cardiologists.
Percutaneous Relief of Tension Pneumomediastinum in a Child
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chau, Helen Hoi-lun; Kwok, Philip Chong-hei; Lai, Albert Kwok-hung
2003-11-15
The purpose of this article was to describe the experience of relieving tension pneumomediastinum by a fluoroscopic-guided percutaneous method. We inserted a percutaneous drainage catheter with a Heimlich valve under fluoroscopic guidance to relieve the tension pneumomediastinum in a 2-year-old girl who suffered from dermatomyositis with lung involvement. This allowed immediate relief without the need for surgery. The procedure was repeated for relapsed tension pneumomediastinum. Good immediate results were achieved in each attempt. We conclude that percutaneous relief of pneumomediastinum under fluoroscopic guidance can be performed safely and rapidly in patients not fit for surgery.
Occupational health hazards in the interventional laboratory: Time for a safer environment.
Klein, Lloyd W; Miller, Donald L; Balter, Stephen; Laskey, Warren; Naito, Neil; Haines, David; Ross, Allan; Mauro, Matthew A; Goldstein, James A
2018-01-04
Over the past 30 years, the advent of fluoroscopically guided interventional procedures has resulted in dramatic increments in both X-ray exposure and physical demands that predispose interventionists to distinct occupational health hazards. The hazards of accumulated radiation exposure have been known for years, but until recently the other potential risks have been ill-defined and under-appreciated. The physical stresses inherent in this career choice appear to be associated with a predilection to orthopedic injuries, attributable in great part to the cumulative adverse effects of bearing the weight and design of personal protective apparel worn to reduce radiation risk and to the poor ergonomic design of interventional suites. These occupational health concerns pertain to cardiologists, radiologists and surgeons working with fluoroscopy, pain management specialists performing nonvascular fluoroscopic procedures, and the many support personnel working in these environments. This position paper is the work of representatives of the major societies of physicians who work in the interventional laboratory environment, and has been formally endorsed by all. In this paper, the available data delineating the prevalence of these occupational health risks is reviewed and ongoing epidemiological studies designed to further elucidate these risks are summarized. The main purpose is to publicly state speaking with a single voice that the interventional laboratory poses workplace hazards that must be acknowledged, better understood and mitigated to the greatest extent possible, and to advocate vigorously on behalf of efforts to reduce these hazards. Interventional physicians and their professional societies, working together with industry, should strive toward the ultimate zero radiation exposure work environment that would eliminate the need for personal protective apparel and prevent its orthopedic and ergonomic consequences. © 2008 Wiley-Liss, Inc. Copyright © 2008 Wiley‐Liss, Inc.
Manchikanti, Laxmaiah; Cash, Kim A; Pampati, Vidyasagar; Damron, Kim S; McManus, Carla D
2004-04-01
Transforaminal epidural steroid injection is one of the commonly employed modalities of treatment in managing nerve root pain. However, there have been no controlled prospective evaluations of epidural and nerve root contrast distribution patterns and other aspects of fluoroscopically directed lumbosacral transforaminal epidural steroid injections. To evaluate contrast flow patterns and intravascular needle placement of fluoroscopically guided lumbosacral transforaminal epidural injections. A prospective, observational study. A total of 100 consecutive patients undergoing fluoroscopically guided transforaminal epidural steroid injections were evaluated. The contrast flow patterns, ventral or dorsal epidural filling, nerve root filling, C-arm time, and intravascular needle placement were evaluated. Ventral epidural filling was seen in 88% of the procedures, in contrast to dorsal filling noted in 9% of the procedures. Nerve root filling was seen in 97% of the procedures. Total intravenous placement of the needle was noted in 22% of the procedures, whereas negative flashback and aspiration was noted in 5% of the procedures. Lumbosacral transforaminal epidural injections, performed under fluoroscopic visualization, provide excellent nerve root filling and ventral epidural filling patterns. However, unrecognized intravascular needle placement with negative flashback or aspiration was noted in 5% of the procedures.
Usawachintachit, Manint; Masic, Selma; Allen, Isabel E.; Li, Jianxing
2016-01-01
Abstract Objectives: To define the learning curve associated with adopting ultrasound guidance for prone percutaneous nephrolithotomy (PCNL) for the experienced surgeon. Methods: A prospective cohort study of consecutive patients undergoing PCNL with ultrasound guidance for renal tract access and dilation was performed. Clinical data reviewed included success in gaining renal access with ultrasound guidance, total fluoroscopic screening time, and radiation exposure dose. PCNL cases performed with fluoroscopic guidance matched for stone size served as control cases. Results: One hundred consecutive ultrasound-guided procedures performed by a single experienced endourologist were divided into five experience groups. Significant improvement in renal access success rate with ultrasound was seen after 20 cases (p < 0.05). Total fluoroscopic screening time, radiation exposure dose, and operative time were also statistically significantly improved over the study period. When compared with fluoroscopy-guided PCNL, significant decreases in total fluoroscopic screening time (33.4 ± 35.3 seconds vs 157.5 ± 84.9 seconds, p < 0.05) and radiation exposure (7.0 ± 8.7 mGy vs 47.8 ± 45.9 mGy, p < 0.05) were seen. No differences in complication rates were found. Conclusions: Ultrasound-guided renal access for PCNL can be performed effectively after 20 cases. Transition to the use of ultrasound will quickly reduce radiation exposure for patients and intraoperative personnel. PMID:27150671
Kim, Honsoul; Kim, Seung Hyoung; Choi, Sun Young; Lee, Kwang-Hun; Won, Jong Yoon; Lee, Do Yun; Lee, Jong Tae
2008-12-01
To evaluate the technical feasibility and clinical effectiveness of fluoroscopically guided placement of self-expandable metallic stents and stent-grafts for acute malignant colorectal obstruction. Radiologic images and clinical reports of 42 patients (22 men, 20 women; age range, 28-93 years; median age, 65.5 years) who underwent fluoroscopically guided colorectal stent insertion without endoscopic assistance for acute malignant obstruction were reviewed retrospectively. Eighteen patients received bare stents as a bridge to surgery. Twenty-four patients received 27 insertions of either a bare stent (n = 15) or a stent-graft (n = 12) for palliation. The obstruction was located in the rectum (n = 8), sigmoid (n = 17), descending colon (n = 8), splenic flexure (n = 3), and transverse colon (n = 6). Clinical success, defined as more than 50% dilatation of the stent with subsequent symptomatic improvement, was achieved in 41 of the 42 patients (98%). No major procedure-related complications occurred. Minor complications occurred in eight of the 45 procedures (18%). No perioperative mortalities occurred within 1 month after surgery. In the palliative group, the median stent patency was 62 days (range, 0-1,014 days). There was no statistically significant difference in stent patency between the bare stents (range, 0-855 days; median, 68 days) and stent-grafts (range, 1-1,014 days; median, 81 days). Fluoroscopically guided placement of self-expandable metallic stents and stent-grafts for the relief of acute malignant colorectal obstruction was technically feasible without endoscopic assistance-even in lesions proximal to the splenic flexure and transverse colon-and clinically effective in both bridge to surgery and palliative management.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ryan, E. Ronan, E-mail: ronan@ronanryan.com; Thornton, Raymond; Sofocleous, Constantinos T.
PurposeTo quantify radiation exposure to the primary operator and staff during PET/CT-guided interventional procedures.MethodsIn this prospective study, 12 patients underwent PET/CT-guided interventions over a 6 month period. Radiation exposure was measured for the primary operator, the radiology technologist, and the nurse anesthetist by means of optically stimulated luminescence dosimeters. Radiation exposure was correlated with the procedure time and the use of in-room image guidance (CT fluoroscopy or ultrasound).ResultsThe median effective dose was 0.02 (range 0-0.13) mSv for the primary operator, 0.01 (range 0-0.05) mSv for the nurse anesthetist, and 0.02 (range 0-0.05) mSv for the radiology technologist. The median extremitymore » dose equivalent for the operator was 0.05 (range 0-0.62) mSv. Radiation exposure correlated with procedure duration and with the use of in-room image guidance. The median operator effective dose for the procedure was 0.015 mSv when conventional biopsy mode CT was used, compared to 0.06 mSv for in-room image guidance, although this did not achieve statistical significance as a result of the small sample size (p = 0.06).ConclusionThe operator dose from PET/CT-guided procedures is not significantly different than typical doses from fluoroscopically guided procedures. The major determinant of radiation exposure to the operator from PET/CT-guided interventional procedures is time spent in close proximity to the patient.« less
Hu, Hong-Tao; Shin, Ji Hoon; Kim, Jin-Hyoung; Jang, Jong Keon; Park, Jung-Hoon; Kim, Tae-Hyung; Nam, Deok Ho; Song, Ho-Young
2015-07-01
We aimed to evaluate the safety and clinical effectiveness of fluoroscopically guided large balloon dilatation for treating congenital esophageal stenosis in children. Our study included seven children (mean age 4.0 years) who underwent a total of ten balloon dilatation sessions. The initial balloon diameters were 10-15 mm. The technical success, clinical success (improved food intake and reduced dysphagia within 1 month following the first balloon dilatation), dysphagia recurrence, and complications were retrospectively evaluated. Technical and clinical success rates were 100 %. During the mean 38-month follow-up period after the first balloon dilatation, 3 (43 %) patients underwent only one additional balloon dilatation 4-5 months after the first balloon dilatation for dysphagia recurrence. Two of them showed improvement without further recurrence, while the remaining one underwent partial esophagectomy. Well-contained transmural esophageal rupture (type 2) occurred in two (29 %, 2/7) patients and during two (20 %, 2/10) balloon dilatation sessions. All ruptures were successfully treated conservatively. Our study showed that fluoroscopically guided large balloon dilatation seems to be a simple and effective primary treatment technique for congenital esophageal stenosis in children. Esophageal ruptures were not uncommon although they were not fatal.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yang, Xiu-Jun, E-mail: woothingyang2008@126.com; Xing, Guang-Fu, E-mail: xgf8848@126.com
ObjectiveTo describe a new interventional technique to remove foreign bodies (FBs) embedded in soft tissues around vital vessels.MethodsUnder fluoroscopic guidance and using local anesthesia, percutaneous removal of FBs was performed using forceps in nine patients. All patients suffered from a metallic soft tissue FB located in close proximity to important vessels and one also had a small traumatic pseudoaneurysm adjacent to the FB. Prior to removal of the FB, the position of the nearest vessel was identified using a guide wire or catheter placed into the vessel. Balloon catheter was also simultaneously used to temporarily stop the blood flow ofmore » the nearest artery during the FB removal in three of the nine patients.ResultsAll of the nine FBs with 0–2 mm interval to the nearest vessel were successfully removed in the nine patients without any serious complications. The removed FBs measured 3–12 mm in length and 1–3 mm in width. The total fluoroscopic time of retrieval of each FB was 5–9 min (mean, 6.4 min). The volume of intraoperative bleeding ranged from 5 to 12 ml (mean, 7.5 ml). The length of hospital stay for each patient ranged from 4 to 8 days (mean, 5.5 days).ConclusionVascular intervention-aided percutaneous FB removal is minimally invasive and an effective method for removal of FBs around vital vessels.« less
NASA Astrophysics Data System (ADS)
Marshall, Emily L.; Borrego, David; Tran, Trung; Fudge, James C.; Bolch, Wesley E.
2018-03-01
Epidemiologic data demonstrate that pediatric patients face a higher relative risk of radiation induced cancers than their adult counterparts at equivalent exposures. Infants and children with congenital heart defects are a critical patient population exposed to ionizing radiation during life-saving procedures. These patients will likely incur numerous procedures throughout their lifespan, each time increasing their cumulative radiation absorbed dose. As continued improvements in long-term prognosis of congenital heart defect patients is achieved, a better understanding of organ radiation dose following treatment becomes increasingly vital. Dosimetry of these patients can be accomplished using Monte Carlo radiation transport simulations, coupled with modern anatomical patient models. The aim of this study was to evaluate the performance of the University of Florida/National Cancer Institute (UF/NCI) pediatric hybrid computational phantom library for organ dose assessment of patients that have undergone fluoroscopically guided cardiac catheterizations. In this study, two types of simulations were modeled. A dose assessment was performed on 29 patient-specific voxel phantoms (taken as representing the patient’s true anatomy), height/weight-matched hybrid library phantoms, and age-matched reference phantoms. Two exposure studies were conducted for each phantom type. First, a parametric study was constructed by the attending pediatric interventional cardiologist at the University of Florida to model the range of parameters seen clinically. Second, four clinical cardiac procedures were simulated based upon internal logfiles captured by a Toshiba Infinix-i Cardiac Bi-Plane fluoroscopic unit. Performance of the phantom library was quantified by computing both the percent difference in individual organ doses, as well as the organ dose root mean square values for overall phantom assessment between the matched phantoms (UF/NCI library or reference) and the patient-specific phantoms. The UF/NCI hybrid phantoms performed at percent differences of between 15% and 30% for the parametric set of irradiation events. Among internal logfile reconstructed procedures, the UF/NCI hybrid phantoms performed with RMS organ dose values between 7% and 29%. Percent improvement in organ dosimetry via the use of hybrid library phantoms over the reference phantoms ranged from 6.6% to 93%. The use of a hybrid phantom library, Monte Carlo radiation transport methods, and clinical information on irradiation events provide a means for tracking organ dose in these radiosensitive patients undergoing fluoroscopically guided cardiac procedures. This work was supported by Advanced Laboratory for Radiation Dosimetry Studies, University of Florida, American Association of University Women, National Cancer Institute Grant 1F31 CA159464.
Wang, Kundong; Chen, Bing; Lu, Qingsheng; Li, Hongbing; Liu, Manhua; Shen, Yu; Xu, Zhuoyan
2018-05-15
Endovascular interventional surgery (EIS) is performed under a high radiation environment at the sacrifice of surgeons' health. This paper introduces a novel endovascular interventional surgical robot that aims to reduce radiation to surgeons and physical stress imposed by lead aprons during fluoroscopic X-ray guided catheter intervention. The unique mechanical structure allowed the surgeon to manipulate the axial and radial motion of the catheter and guide wire. Four catheter manipulators (to manipulate the catheter and guide wire), and a control console which consists of four joysticks, several buttons and two twist switches (to control the catheter manipulators) were presented. The entire robotic system was established on a master-slave control structure through CAN (Controller Area Network) bus communication, meanwhile, the slave side of this robotic system showed highly accurate control over velocity and displacement with PID controlling method. The robotic system was tested and passed in vitro and animal experiments. Through functionality evaluation, the manipulators were able to complete interventional surgical motion both independently and cooperatively. The robotic surgery was performed successfully in an adult female pig and demonstrated the feasibility of superior mesenteric and common iliac artery stent implantation. The entire robotic system met the clinical requirements of EIS. The results show that the system has the ability to imitate the movements of surgeons and to accomplish the axial and radial motions with consistency and high-accuracy. Copyright © 2018 John Wiley & Sons, Ltd.
Occupational Health Risks in Cardiac Catheterization Laboratory Workers.
Andreassi, Maria Grazia; Piccaluga, Emanuela; Guagliumi, Giulio; Del Greco, Maurizio; Gaita, Fiorenzo; Picano, Eugenio
2016-04-01
Orthopedic strain and radiation exposure are recognized risk factors in personnel staff performing fluoroscopically guided cardiovascular procedures. However, the potential occupational health effects are still unclear. The purpose of this study was to examine the prevalence of health problems among personnel staff working in interventional cardiology/cardiac electrophysiology and correlate them with the length of occupational radiation exposure. We used a self-administered questionnaire to collect demographic information, work-related information, lifestyle-confounding factors, all current medications, and health status. A total number of 746 questionnaires were properly filled comprising 466 exposed staff (281 males; 44±9 years) and 280 unexposed subjects (179 males; 43±7years). Exposed personnel included 218 interventional cardiologists and electrophysiologists (168 males; 46±9 years); 191 nurses (76 males; 42±7 years), and 57 technicians (37 males; 40±12 years) working for a median of 10 years (quartiles: 5-24 years). Skin lesions (P=0.002), orthopedic illness (P<0.001), cataract (P=0.003), hypertension (P=0.02), and hypercholesterolemia (P<0.001) were all significantly higher in exposed versus nonexposed group, with a clear gradient unfavorable for physicians over technicians and nurses and for longer history of work (>16 years). In highly exposed physicians, adjusted odds ratio ranged from 1.7 for hypertension (95% confidence interval: 1-3; P=0.05), 2.9 for hypercholesterolemia (95% confidence interval: 1-5; P=0.004), 4.5 for cancer (95% confidence interval: 0.9-25; P=0.06), to 9 for cataract (95% confidence interval: 2-41; P=0.004). Health problems are more frequently observed in workers performing fluoroscopically guided cardiovascular procedures than in unexposed controls, raising the need to spread the culture of safety in the cath laboratory. © 2016 American Heart Association, Inc.
NASA Astrophysics Data System (ADS)
Russ, M.; Shankar, A.; Setlur Nagesh, S. V.; Ionita, C. N.; Bednarek, D. R.; Rudin, S.
2017-03-01
X-ray detectors to meet the high-resolution requirements for endovascular image-guided interventions (EIGIs) are being developed and evaluated. A new 49.5-micron pixel prototype detector is being investigated and compared to the current suite of high-resolution fluoroscopic (HRF) detectors. This detector featuring a 300-micron thick CsI(Tl) scintillator, and low electronic noise CMOS readout is designated the HRF- CMOS50. To compare the abilities of this detector with other existing high resolution detectors, a standard performance metric analysis was applied, including the determination of the modulation transfer function (MTF), noise power spectra (NPS), noise equivalent quanta (NEQ), and detective quantum efficiency (DQE) for a range of energies and exposure levels. The advantage of the smaller pixel size and reduced blurring due to the thin phosphor was exemplified when the MTF of the HRF-CMOS50 was compared to the other high resolution detectors, which utilize larger pixels, other optical designs or thicker scintillators. However, the thinner scintillator has the disadvantage of a lower quantum detective efficiency (QDE) for higher diagnostic x-ray energies. The performance of the detector as part of an imaging chain was examined by employing the generalized metrics GMTF, GNEQ, and GDQE, taking standard focal spot size and clinical imaging parameters into consideration. As expected, the disparaging effects of focal spot unsharpness, exacerbated by increasing magnification, degraded the higher-frequency performance of the HRF-CMOS50, while increasing scatter fraction diminished low-frequency performance. Nevertheless, the HRF-CMOS50 brings improved resolution capabilities for EIGIs, but would require increased sensitivity and dynamic range for future clinical application.
Fluoroscopic Placement of Double-Pigtail Ureteral Stents
Chen, Gregory L.
2001-01-01
Purpose: Double-pigtail ureteral stent is placed cystoscopically after ureteroscopy. We describe a technique for fluoroscopic placement of ureteral stents and demonstrate its use in a non-randomized prospective study. Materials and methods: Double-pigtail stents were placed either fluoroscopically or cystoscopically in 121 consecutive patients. In the fluoroscopic method, the stent was placed over a guide wire using a stent pusher without the use of cystoscopy. Conversely, stents were placed through the working channel of the cystoscope under vision. The procedure, stent length, width, type, method, ureteral dilation, and use of a retrieval string were noted. Results: A wide range of stent sizes were used. The success with fluoroscopic placement of double-pigtail ureteral stents was 100% (89 of 89 cases). No stents migrated or required replacement. Stents were placed after ureteroscopic laser lithotripsy (53/89) and ureteroscopic tumor treatment (22/89). Cystoscopic visualization was used in 32 additional procedures requiring precise control (15 ureteral strictures and nine retrograde endopyelotomy). Conclusions: The fluoroscopic placement of ureteral stents is a safe and simple technique with a very high success rate. We have used cystoscopic placement only after incisional procedures such as retrograde endopyelotomy, stricture or ureterotomy. PMID:18493562
Fiorella, David; Arthur, Adam; Schafer, Sebastian
2015-08-01
The Apollo system (Penumbra Inc, Alameda, California, USA) is a low profile irrigation-aspiration system designed for the evacuation of intracranial hemorrhage. To demonstrate the feasibility of using Apollo in combination with cone beam CT guidance. Parenchymal (n=1) and mixed parenchymal-intraventricular hematomas (n=1) were created in cadaver heads using a transvascular (n=1) or transcranial (n=1) approach. Hematomas were then imaged with cone beam CT (CB-CT), and the long axis of the hematoma defined. The CB-CT data were then used to guide transcranial access to the hematoma-defining the location of the burr hole and the path to the leading edge of the hematoma. An 8F vascular sheath was then placed under live fluoroscopic guidance into the hematoma. A second CB-CT was performed to confirm localization of the sheath. The hematoma was then demarcated on the CB-CT and the Apollo wand was introduced through the 8F sheath and irrigation-aspiration was performed under (periodic) live fluoroscopic guidance. The operators manipulated the wand within the visible boundaries of the hematoma. After irrigation-aspiration, a control CB-CT was performed to document reduction in hematoma volume. Transvascular and transcranial techniques were both successful in creating intracranial hematomas. Hematomas could be defined with conspicuity sufficient for localization and volumetric measurement using CB-CT. Live fluoroscopic guidance was effective in navigating a sheath into the leading aspect of a parenchymal hematoma and guiding irrigation-aspiration with the Apollo system. Irrigation-aspiration reduced the parenchymal hemorrhage volume from 14.8 to 1.7 cc in 189 s in the first case (parenchymal hemorrhage) and from 26.4 to 4.1 cc in 300 s in the second case (parenchymal and intraventricular hemorrhage). The cadaver model described is a useful means of studying interventional techniques for intracranial hemorrhage. It seems feasible to use CB-CT to guide the evacuation of intraparenchymal and intraventricular hemorrhage using the Apollo system through a minimally invasive transcranial access. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Kennedy, David J; Engel, Andrew; Kreiner, D Scott; Nampiaparampil, Devi; Duszynski, Belinda; MacVicar, John
2015-08-01
To assess the validity of fluoroscopically guided diagnostic intra-articular injections of local anesthetic and effectiveness of intra-articular steroid injections in treating sacroiliac joint (SIJ) pain. Systematic review. Ten reviewers independently assessed 45 publications on diagnostic validity or effectiveness of fluoroscopically guided intra-articular SIJ injections. For diagnostic injections, the primary outcome was validity; for therapeutic injections, analgesia. Secondary outcomes were also described. Of 45 articles reviewed, 39 yielded diagnostic data on physical exam findings, provocation tests, and SIJ injections for diagnosing SIJ pain, and 15 addressed therapeutic effectiveness. When confirmed by comparative local anesthetic blocks with a high degree of pain relief, no single physical exam maneuver predicts response to diagnostic injections. When at least three physical exam findings are present, sensitivity, and specificity increases significantly. The prevalence of SIJ pain is likely 20-30% among patients that have suspected SIJ pain based on history and physical examination. This estimate may be higher in certain subgroups such as the elderly and fusion patients. Two randomized controlled trials and multiple observational studies supported the effectiveness of therapeutic sacroiliac joint injections. Based on this literature, it is unclear whether image-guided intra-articular diagnostic injections of local anesthetic predict positive responses to therapeutic agents. The overall quality of evidence is moderate for the effectiveness of therapeutic SIJ injections. Wiley Periodicals, Inc.
MRI-guided and CT-guided cervical nerve root infiltration therapy: a cost comparison.
Maurer, M H; Froeling, V; Röttgen, R; Bretschneider, T; Hartwig, T; Disch, A C; de Bucourt, M; Hamm, B; Streitparth, F
2014-06-01
To evaluate and compare the costs of MRI-guided and CT-guided cervical nerve root infiltration for the minimally invasive treatment of radicular neck pain. Between September 2009 and April 2012, 22 patients (9 men, 13 women; mean age: 48.2 years) underwent MRI-guided (1.0 Tesla, Panorama HFO, Philips) single-site periradicular cervical nerve root infiltration with 40 mg triamcinolone acetonide. A further 64 patients (34 men, 30 women; mean age: 50.3 years) were treated under CT fluoroscopic guidance (Somatom Definition 64, Siemens). The mean overall costs were calculated as the sum of the prorated costs of equipment use (purchase, depreciation, maintenance, and energy costs), personnel costs and expenditure for disposables that were identified for MRI- and CT-guided procedures. Additionally, the cost of ultrasound guidance was calculated. The mean intervention time was 24.9 min. (range: 12 - 36 min.) for MRI-guided infiltration and 19.7 min. (range: 5 - 54 min.) for CT-guided infiltration. The average total costs per patient were EUR 240 for MRI-guided interventions and EUR 124 for CT-guided interventions. These were (MRI/CT guidance) EUR 150/60 for equipment use, EUR 46/40 for personnel, and EUR 44/25 for disposables. The mean overall cost of ultrasound guidance was EUR 76. Cervical nerve root infiltration using MRI guidance is still about twice as expensive as infiltration using CT guidance. However, since it does not involve radiation exposure for patients and personnel, MRI-guided nerve root infiltration may become a promising alternative to the CT-guided procedure, especially since a further price decrease is expected for MRI devices and MR-compatible disposables. In contrast, ultrasound remains the less expensive method for nerve root infiltration guidance. © Georg Thieme Verlag KG Stuttgart · New York.
Malignant biliary disease: percutaneous interventions.
Morgan, R A; Adam, A N
2001-09-01
Interventional radiologists have an important role in the management of patients with malignant biliary obstruction. This article describes the techniques for percutaneous biliary drainage, insertion of biliary endoprostheses, and the management of occluded biliary endoprostheses. Most procedures are performed by using fluoroscopic guidance alone. Ultrasound is also a useful modality for guiding biliary drainage, particularly drainage of the left biliary ducts. Patients should be treated by internal drainage if possible. Metallic endoprostheses can be inserted at the time of the initial biliary drainage procedure. Plastic tubes should be inserted a few days after biliary drainage because of their relatively large size compared with metallic stents. Occluded plastic stents should be replaced. Blocked metallic stents should be treated either by placement of additional overlapping metallic stents or by placement of plastic stents within the metallic stent lumen. Copyright 2001 by W.B. Saunders Company
Chiu, Chee Kidd; Chan, Chris Yin Wei; Kwan, Mun Keong
2017-01-01
This study investigates the safety and accuracy of percutaneous pedicle screws placed using fluoroscopic guidance in the thoracolumbosacral spine among Asian patients. Computerized tomography scans of 128 patients who had surgery using fluoroscopic-guided percutaneous pedicle screws were selected. Medial, lateral, superior, and inferior screw perforations were classified into grade 0 (no violation), grade 1 (<2 mm perforation), grade 2 (2-4 mm perforation), and grade 3(>4 mm perforation). Anterior perforations were classified into grade 0 (no violation), grade 1 (<4 mm perforation), grade 2 (4-6 mm perforation), and grade 3(>6 mm perforation). Grade 2 and grade 3 perforation were considered as "critical" perforation. In total, 1002 percutaneous pedicle screws from 128 patients were analyzed. The mean age was 52.7 ± 16.6. There were 70 male patients and 58 female patients. The total perforation rate was 11.3% (113) with 8.4% (84) grade 1, 2.6% (26) grade 2, and 0.3% (3) grade 3 perforations. The overall "critical" perforation rate was 2.9% (29 screws) and no complications were noted. The highest perforation rates were at T4 (21.6%), T2 (19.4%), and T6 (19.2%). The total perforation rate of 11.3% with the total "critical" perforation rate of 2.9% (2.6% grade 2 and 0.3% grade 3 perforations). The highest perforation rates were found over the upper to mid-thoracic region. Fluoroscopic-guided percutaneous pedicle screws insertion among Asians has the safety and accuracy comparable to the current reported percutaneous pedicle screws and open pedicle screws techniques.
Toward Simultaneous Real-Time Fluoroscopic and Nuclear Imaging in the Intervention Room.
Beijst, Casper; Elschot, Mattijs; Viergever, Max A; de Jong, Hugo W A M
2016-01-01
To investigate the technical feasibility of hybrid simultaneous fluoroscopic and nuclear imaging. An x-ray tube, an x-ray detector, and a gamma camera were positioned in one line, enabling imaging of the same field of view. Since a straightforward combination of these elements would block the lines of view, a gamma camera setup was developed to be able to view around the x-ray tube. A prototype was built by using a mobile C-arm and a gamma camera with a four-pinhole collimator. By using the prototype, test images were acquired and sensitivity, resolution, and coregistration error were analyzed. Nuclear images (two frames per second) were acquired simultaneously with fluoroscopic images. Depending on the distance from point source to detector, the system resolution was 1.5-1.9-cm full width at half maximum, the sensitivity was (0.6-1.5) × 10(-5) counts per decay, and the coregistration error was -0.13 to 0.15 cm. With good spatial and temporal alignment of both modalities throughout the field of view, fluoroscopic images can be shown in grayscale and corresponding nuclear images in color overlay. Measurements obtained with the hybrid imaging prototype device that combines simultaneous fluoroscopic and nuclear imaging of the same field of view have demonstrated the feasibility of real-time simultaneous hybrid imaging in the intervention room. © RSNA, 2015
Intraoperative fluoroscopic evaluation of screw placement during pelvic and acetabular surgery.
Yi, Chengla; Burns, Sean; Hak, David J
2014-01-01
The surgical treatment of pelvic and acetabular fractures can be technically challenging. Various techniques are available for the reconstruction of pelvic and acetabular fractures. Less invasive percutaneous fracture stabilization techniques, with closed reduction or limited open reduction, have been developed and are gaining popularity in the management of pelvic and acetabular fractures. These techniques require knowledge and interpretation of various fluoroscopic images to ensure appropriate and safe screw placement. Given the anatomic complexity of the intrapelvic structures and the 2-dimensional nature of standard fluoroscopy, multiple images oriented in different planes are needed to assess the accuracy of guide wire and screw placement. This article reviews the fluoroscopic imaging of common screw orientations during pelvic and acetabular surgery.
NASA Astrophysics Data System (ADS)
Kilian-Meneghin, Josh; Xiong, Z.; Rudin, S.; Oines, A.; Bednarek, D. R.
2017-03-01
The purpose of this work is to evaluate methods for producing a library of 2D-radiographic images to be correlated to clinical images obtained during a fluoroscopically-guided procedure for automated patient-model localization. The localization algorithm will be used to improve the accuracy of the skin-dose map superimposed on the 3D patient- model of the real-time Dose-Tracking-System (DTS). For the library, 2D images were generated from CT datasets of the SK-150 anthropomorphic phantom using two methods: Schmid's 3D-visualization tool and Plastimatch's digitally-reconstructed-radiograph (DRR) code. Those images, as well as a standard 2D-radiographic image, were correlated to a 2D-fluoroscopic image of a phantom, which represented the clinical-fluoroscopic image, using the Corr2 function in Matlab. The Corr2 function takes two images and outputs the relative correlation between them, which is fed into the localization algorithm. Higher correlation means better alignment of the 3D patient-model with the patient image. In this instance, it was determined that the localization algorithm will succeed when Corr2 returns a correlation of at least 50%. The 3D-visualization tool images returned 55-80% correlation relative to the fluoroscopic-image, which was comparable to the correlation for the radiograph. The DRR images returned 61-90% correlation, again comparable to the radiograph. Both methods prove to be sufficient for the localization algorithm and can be produced quickly; however, the DRR method produces more accurate grey-levels. Using the DRR code, a library at varying angles can be produced for the localization algorithm.
Fernández-Gutiérrez, Fabiola; Martínez, Santiago; Rube, Martin A; Cox, Benjamin F; Fatahi, Mahsa; Scott-Brown, Kenneth C; Houston, J Graeme; McLeod, Helen; White, Richard D; French, Karen; Gueorguieva, Mariana; Immel, Erwin; Melzer, Andreas
2015-10-01
A methodological framework is introduced to assess and compare a conventional fluoroscopy protocol for peripheral angioplasty with a new magnetic resonant imaging (MRI)-guided protocol. Different scenarios were considered during interventions on a perfused arterial phantom with regard to time-based and cognitive task analysis, user experience and ergonomics. Three clinicians with different expertise performed a total of 43 simulated common iliac angioplasties (9 fluoroscopic, 34 MRI-guided) in two blocks of sessions. Six different configurations for MRI guidance were tested in the first block. Four of them were evaluated in the second block and compared to the fluoroscopy protocol. Relevant stages' durations were collected, and interventions were audio-visually recorded from different perspectives. A cued retrospective protocol analysis (CRPA) was undertaken, including personal interviews. In addition, ergonomic constraints in the MRI suite were evaluated. Significant differences were found when comparing the performance between MRI configurations versus fluoroscopy. Two configurations [with times of 8.56 (0.64) and 9.48 (1.13) min] led to reduce procedure time for MRI guidance, comparable to fluoroscopy [8.49 (0.75) min]. The CRPA pointed out the main influential factors for clinical procedure performance. The ergonomic analysis quantified musculoskeletal risks for interventional radiologists when utilising MRI. Several alternatives were suggested to prevent potential low-back injuries. This work presents a step towards the implementation of efficient operational protocols for MRI-guided procedures based on an integral and multidisciplinary framework, applicable to the assessment of current vascular protocols. The use of first-user perspective raises the possibility of establishing new forms of clinical training and education.
Percutaneous imaging-guided interventions for acute biliary disorders in high surgical risk patients
Donkol, Ragab Hani; Latif, Nahed Abdel; Moghazy, Khaled
2010-01-01
AIM: To evaluate the efficacy of percutaneous imaging-guided biliary interventions in the management of acute biliary disorders in high surgical risk patients. METHODS: One hundred and twenty two patients underwent 139 percutaneous imaging-guided biliary interventions during the period between January 2007 to December 2009. The patients included 73 women and 49 men with a mean age of 61 years (range 35-90 years). Fifty nine patients had acute biliary obstruction, 26 patients had acute biliary infection and 37 patients had abnormal collections. The procedures were performed under computed tomography (CT)- (73 patients), sonographic- (41 patients), and fluoroscopic-guidance (25 patients). Success rates and complications were determined. The χ2 test with Yates’ correction for continuity was applied to compare between these procedures. A P value < 0.05 was considered significant. RESULTS: The success rates for draining acute biliary obstruction under CT- , fluoroscopy- or ultrasound-guidance were 93.3%, 62.5% and 46.1%, respectively with significant P values (P = 0.026 and 0.002, respectively). In acute biliary infection, successful drainage was achieved in 22 patients (84.6%). The success rates in patients drained under ultrasound- and CT-guidance were 46.1% and 88.8%, respectively and drainage under CT-guidance was significantly higher (P = 0.0293). In 13 patients with bilomas, percutaneous drainage was successful in 11 patients (84.6%). Ten out of 12 cases with hepatic abscesses were drained with a success rate of 83.3%. In addition, the success rate of drainage in 12 cases with pancreatic pseudocysts was 83.3%. The reported complications were two deaths, four major and seven minor complications. CONCLUSION: Percutaneous imaging-guided biliary interventions help to promptly diagnose and effectively treat acute biliary disorders. They either cure the disorders or relieve sepsis and jaundice before operations. PMID:21160698
Technique for CT Fluoroscopy-Guided Lumbar Medial Branch Blocks and Radiofrequency Ablation.
Amrhein, Timothy J; Joshi, Anand B; Kranz, Peter G
2016-09-01
The purpose of this study is to describe the procedure for CT fluoroscopy-guided lumbar medial branch blocks and facet radiofrequency ablation. CT fluoroscopic guidance allows more-precise needle tip positioning and is an alternative method for performing medial branch blocks and facet radiofrequency ablation.
Lerman, Imanuel R; Souzdalnitski, Dmitri; Narouze, Samer
2012-01-01
This technical report describes a durable, low-cost, anatomically accurate, and easy-to-prepare combined ultrasound (US) and fluoroscopic phantom of the cervical spine. This phantom is meant to augment training in US- and fluoroscopic-guided pain medicine procedures. The combined US and fluoroscopic phantom (CUF-P) is prepared from commercially available liquid plastic that is ordinarily used to prepare synthetic fishing lures. The liquid plastic is heated and then poured into a metal canister that houses an anatomical cervical spine model. Drops of dark purple dye are added to make the phantom opaque. After cooling, tubing is attached to the CUF-P to simulate blood vessels. The CUF-P accurately simulates human tissue by imitating both the tactile texture of skin and the haptic resistance of human tissue as the needle is advanced. This phantom contains simulated fluid-filled vertebral arteries that exhibit pulsed flow under color Doppler US. Under fluoroscopic examination, the CUF-P-simulated vertebral arteries also exhibit uptake of contrast dye if mistakenly injected. The creation of a training phantom allows the pain physician to practice needle positioning technique while simultaneously visualizing both targeted and avoidable vascular structures under US and fluoroscopic guidance. This low-cost CUF-P is easy to prepare and is reusable, making it an attractive alternative to current homemade and commercially available phantom simulators.
Hoffmann, Michael; Schröder, Malte; Lehmann, Wolfgang; Kammal, Michael; Rueger, Johannes Maria; Herrman Ruecker, Andreas
2012-07-01
Distal locking marks one challenging step during intramedullary nailing that can lead to an increased irradiation and prolonged operation times. The aim of this study was to evaluate the reliability and efficacy of an X-ray-radiation-free real-time navigation system for distal locking procedures. A prospective randomized cadaver study with 50 standard free-hand fluoroscopic-guided and 50 electromagnetic-guided distal locking procedures was performed. All procedures were timed using a stopwatch. Intraoperative fluoroscopy exposure time and absorbed radiation dose (mGy) readings were documented. All tibial nails were locked with two mediolateral and one anteroposterior screw. Successful distal locking was accomplished once correct placement of all three screws was confirmed. Successful distal locking was achieved in 98 cases. No complications were encountered using the electromagnetic navigation system. Eight complications arose during free-hand fluoroscopic distal locking. Undetected secondary drill slippage on the ipsilateral cortex accounted for most problems followed by undetected intradrilling misdirection causing a fissural fracture of the contralateral cortex while screw insertion in one case. Compared with the free-hand fluoroscopic technique, electromagnetically navigated distal locking provides a median time benefit of 244 seconds without using ionizing radiation. Compared with the standard free-hand fluoroscopic technique, the electromagnetic guidance system used in this study showed high reliability and was associated with less complications, took significantly less time, and used no radiation exposure for distal locking procedures. Therapeutic study, level II.
Cook, J L; Tomlinson, J L; Reed, A L
1999-01-01
To report a technique for fluoroscopically guided closed reduction with internal fixation of fractures of the lateral portion of the humeral condyle (FLHC) and determine the long-term results in 10 clinical cases. Prospective clinical case study. Ten dogs with 11 fractures. Fractures of the lateral portion of the humeral condyle were stabilized with transcondylar screws and Kirschner wires. Closed reduction and implant placement were achieved using intraoperative fluoroscopic guidance. After fracture repair, postoperative radiographs were evaluated for articular alignment and implant placement. Dogs were evaluated after surgery by means of lameness scores, elbow range of motion (ROM), radiographic assessment, and owner evaluation of function. Postoperative reduction was considered anatomic in 6 fractures with all other fractures having <1.5 mm of malreduction. Follow-up was available for 9 patients from 9 to 21 months after surgery. All of the fractures had healed. One minor (wire migration) and one major (implant failure) complication occurred. Mean lameness scores were 0 (n = 6), 0.5 (n = 2), and 1 (n = 1) at the time of final follow-up. No significant differences were found in follow-up ROM values between affected and unaffected elbows. All of the dogs in this study regained 90-100% of full function, based on owner assessment. Fluoroscopic guidance for closed reduction and internal fixation of FLHC in dogs is an effective technique.
den Boer, A; de Feyter, P J; Hummel, W A; Keane, D; Roelandt, J R
1994-06-01
Radiographic technology plays an integral role in interventional cardiology. The number of interventions continues to increase, and the associated radiation exposure to patients and personnel is of major concern. This study was undertaken to determine whether a newly developed x-ray tube deploying grid-switched pulsed fluoroscopy and extra beam filtering can achieve a reduction in radiation exposure while maintaining fluoroscopic images of high quality. Three fluoroscopic techniques were compared: continuous fluoroscopy, pulsed fluoroscopy, and a newly developed high-output pulsed fluoroscopy with extra filtering. To ascertain differences in the quality of images and to determine differences in patient entrance and investigator radiation exposure, the radiated volume curve was measured to determine the required high voltage levels (kVpeak) for different object sizes for each fluoroscopic mode. The fluoroscopic data of 124 patient procedures were combined. The data were analyzed for radiographic projections, image intensifier field size, and x-ray tube kilovoltage levels (kVpeak). On the basis of this analysis, a reference procedure was constructed. The reference procedure was tested on a phantom or dummy patient by all three fluoroscopic modes. The phantom was so designed that the kilovoltage requirements for each projection were comparable to those needed for the average patient. Radiation exposure of the operator and patient was measured during each mode. The patient entrance dose was measured in air, and the operator dose was measured by 18 dosimeters on a dummy operator. Pulsed compared with continuous fluoroscopy could be performed with improved image quality at lower kilovoltages. The patient entrance dose was reduced by 21% and the operator dose by 54%. High-output pulsed fluoroscopy with extra beam filtering compared with continuous fluoroscopy improved the image quality, lowered the kilovoltage requirements, and reduced the patient entrance dose by 55% and the operator dose by 69%. High-output pulsed fluoroscopy with a grid-switched tube and extra filtering improves the image quality and significantly reduces both the operator dose and patient dose.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jones, A.
With the current Maintenance of Certification (MOC) requirement for a practice quality improvement (PQI) project every 3 years, we all (well, most of us) find ourselves searching for projects that are both manageable and likely to have a positive impact on our clinical practice. In this session we will walk through the use of the Plan, Do, Study, Act (PDSA) cycle to address a common finding in practices where fluoroscopically guided interventions (FGI) are performed: variation in procedural doses among physicians. We will also examine strategies to secure physician support using carrots, not sticks. Learning Objectives: Review the PDSA cyclemore » and its application to PQI. Discuss strategies for action in the example presented. Examine strategies for successful group PQI projects. A. Kyle Jones: Owner, FluoroSafety Joseph R. Steele: Consultant, FluoroSafety.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Merritt, Z; Dave, J; Eschelman, D
Purpose: To investigate the effects of image receptor technology and dose reduction software on radiation dose estimates for most frequently performed fluoroscopically-guided interventional (FGI) procedures at a tertiary health care center. Methods: IRB approval was obtained for retrospective analysis of FGI procedures performed in the interventional radiology suites between January-2011 and December-2015. This included procedures performed using image-intensifier (II) based systems which were subsequently replaced, flat-panel-detector (FPD) based systems which were later upgraded with ClarityIQ dose reduction software (Philips Healthcare) and relatively new FPD system already equipped with ClarityIQ. Post procedure, technologists entered system-reported cumulative air kerma (CAK) and kerma-areamore » product (KAP; only KAP for II based systems) in RIS; these values were analyzed. Data pre-processing included correcting typographical errors and cross-verifying CAK and KAP. The most frequent high and low dose FGI procedures were identified and corresponding CAK and KAP values were compared. Results: Out of 27,251 procedures within this time period, most frequent high and low dose procedures were chemo/immuno-embolization (n=1967) and abscess drainage (n=1821). Mean KAP for embolization and abscess drainage procedures were 260,657, 310,304 and 94,908 mGycm{sup 2}, and 14,497, 15,040 and 6307 mGycm{sup 2} using II-, FPD- and FPD with ClarityIQ- based systems, respectively. Statistically significant differences were observed in KAP values for embolization procedures with respect to different systems but for abscess drainage procedures significant differences were only noted between systems with FPD and FPD with ClarityIQ (p<0.05). Mean CAK reduced significantly from 823 to 308 mGy and from 43 to 21 mGy for embolization and abscess drainage procedures, respectively, in transitioning to FPD systems with ClarityIQ (p<0.05). Conclusion: While transitioning from II- to FPD- based systems was not associated with dose reduction for the most frequently performed FGI procedures, substantial dose reduction was noted with relatively newer systems and dose reduction software.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xiong, Z; Vijayan, S; Rana, V
2015-06-15
Purpose: A system was developed that automatically calculates the organ and effective dose for individual fluoroscopically-guided procedures using a log of the clinical exposure parameters. Methods: We have previously developed a dose tracking system (DTS) to provide a real-time color-coded 3D- mapping of skin dose. This software produces a log file of all geometry and exposure parameters for every x-ray pulse during a procedure. The data in the log files is input into PCXMC, a Monte Carlo program that calculates organ and effective dose for projections and exposure parameters set by the user. We developed a MATLAB program to readmore » data from the log files produced by the DTS and to automatically generate the definition files in the format used by PCXMC. The processing is done at the end of a procedure after all exposures are completed. Since there are thousands of exposure pulses with various parameters for fluoroscopy, DA and DSA and at various projections, the data for exposures with similar parameters is grouped prior to entry into PCXMC to reduce the number of Monte Carlo calculations that need to be performed. Results: The software developed automatically transfers data from the DTS log file to PCXMC and runs the program for each grouping of exposure pulses. When the dose from all exposure events are calculated, the doses for each organ and all effective doses are summed to obtain procedure totals. For a complicated interventional procedure, the calculations can be completed on a PC without manual intervention in less than 30 minutes depending on the level of data grouping. Conclusion: This system allows organ dose to be calculated for individual procedures for every patient without tedious calculations or data entry so that estimates of stochastic risk can be obtained in addition to the deterministic risk estimate provided by the DTS. Partial support from NIH grant R01EB002873 and Toshiba Medical Systems Corp.« less
NASA Astrophysics Data System (ADS)
Shankar, A.; Russ, M.; Vijayan, S.; Bednarek, D. R.; Rudin, S.
2017-03-01
Apodized Aperture Pixel (AAP) design, proposed by Ismailova et.al, is an alternative to the conventional pixel design. The advantages of AAP processing with a sinc filter in comparison with using other filters include non-degradation of MTF values and elimination of signal and noise aliasing, resulting in an increased performance at higher frequencies, approaching the Nyquist frequency. If high resolution small field-of-view (FOV) detectors with small pixels used during critical stages of Endovascular Image Guided Interventions (EIGIs) could also be extended to cover a full field-of-view typical of flat panel detectors (FPDs) and made to have larger effective pixels, then methods must be used to preserve the MTF over the frequency range up to the Nyquist frequency of the FPD while minimizing aliasing. In this work, we convolve the experimentally measured MTFs of an Microangiographic Fluoroscope (MAF) detector, (the MAF-CCD with 35μm pixels) and a High Resolution Fluoroscope (HRF) detector (HRF-CMOS50 with 49.5μm pixels) with the AAP filter and show the superiority of the results compared to MTFs resulting from moving average pixel binning and to the MTF of a standard FPD. The effect of using AAP is also shown in the spatial domain, when used to image an infinitely small point object. For detectors in neurovascular interventions, where high resolution is the priority during critical parts of the intervention, but full FOV with larger pixels are needed during less critical parts, AAP design provides an alternative to simple pixel binning while effectively eliminating signal and noise aliasing yet allowing the small FOV high resolution imaging to be maintained during critical parts of the EIGI.
Radiation-Induced Skin Injuries to Patients: What the Interventional Radiologist Needs to Know.
Jaschke, Werner; Schmuth, Matthias; Trianni, Annalisa; Bartal, Gabriel
2017-08-01
For a long time, radiation-induced skin injuries were only encountered in patients undergoing radiation therapy. In diagnostic radiology, radiation exposures of patients causing skin injuries were extremely rare. The introduction of fast multislice CT scanners and fluoroscopically guided interventions (FGI) changed the situation. Both methods carry the risk of excessive high doses to the skin of patients resulting in skin injuries. In the early nineties, several reports of epilation and skin injuries following CT brain perfusion studies were published. During the same time, several papers reported skin injuries following FGI, especially after percutaneous coronary interventions and neuroembolisations. Thus, CT and FGI are of major concern regarding radiation safety since both methods can apply doses to patients exceeding 5 Gy (National Council on Radiation Protection and Measurements threshold for substantial radiation dose level). This paper reviews the problem of skin injuries observed after FGI. Also, some practical advices are given how to effectively avoid skin injuries. In addition, guidelines are discussed how to deal with patients who were exposed to a potentially dangerous radiation skin dose during medically justified interventional procedures.
Minimally invasive radiologically guided intervention for the treatment of salivary calculi.
Brown, Jackie E; Drage, Nicholas A; Escudier, Michael P; Wilson, Ron F; McGurk, Mark
2002-01-01
To describe the technique and examine the value of salivary stone extraction using a minimally invasive, radiologically guided approach as an alternative to salivary gland surgery for the treatment of benign salivary gland obstruction. Eighty-six cases of sialolithiasis (83 patients) were treated by stone removal using a Dormia basket under local anesthesia and fluoroscopic guidance. Postoperative assessment was made clinically at review, by sialogram and by questionnaire. Of 86 cases of sialolithiasis treated, in 55 (64%) it was possible to remove all stones. In 12 cases (14%) part of a stone or some of a number of calculi were removed and in 19 cases (22%) the procedure failed. The commonest reason for failure was fixation of the stone within the duct. Symptoms at review (range 1-49 months, mean 17 months) were relieved in 55 of 67 (82%) of cases where a stone or portion of stone was removed. Stone removal from the salivary duct system by radiologically guided, minimally invasive approach is a simple procedure with low morbidity and high patient acceptance when appropriate selection criteria are applied. These criteria are considered and recommendations made.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Damilakis, J; Stratakis, J; Solomou, G
Purpose: It is well known that pacemaker implantation is sometimes needed in pregnant patients with symptomatic bradycardia. To our knowledge, there is no reported experience regarding radiation doses to the unborn child resulting from fluoroscopy during pacemaker implantation. The purpose of the current study was to develop a method for estimating embryo/fetus dose from fluoroscopically guided pacemaker implantation procedures performed on pregnant patients during all trimesters of gestation. Methods: The Monte Carlo N-Particle (MCNP) radiation transport code was employed in this study. Three mathematical anthropomorphic phantoms representing the average pregnant patient at the first, second and third trimesters of gestationmore » were generated using Bodybuilder software (White Rock science, White Rock, NM). The normalized embryo/fetus dose from the posteroanterior (PA), the 30° left-anterior oblique (LAO) and the 30° right-anterior oblique (RAO) projections were calculated for a wide range of kVp (50–120 kVp) and total filtration values (2.5–9.0 mm Al). Results: The results consist of radiation doses normalized to a) entrance skin dose (ESD) and b) dose area product (DAP) so that the dose to the unborn child from any fluoroscopic technique and x-ray device used can be calculated. ESD normalized doses ranged from 0.008 (PA, first trimester) to 2.519 μGy/mGy (RAO, third trimester). DAP normalized doses ranged from 0.051 (PA, first trimester) to 12.852 μGy/Gycm2 (RAO, third trimester). Conclusion: Embryo/fetus doses from fluoroscopically guided pacemaker implantation procedures performed on pregnant patients during all stages of gestation can be estimated using the method developed in this study. This study was supported by the Greek Ministry of Education and Religious Affairs, General Secretariat for Research and Technology, Operational Program ‘Education and Lifelong Learning’, ARISTIA (Research project: CONCERT)« less
Walsh, Katie A; Galvin, Joseph; Keaney, John; Keelan, Edward; Szeplaki, Gabor
2018-02-23
Zero- and near-zero-fluoroscopic ablation techniques reduce the harmful effects of ionizing radiation during invasive electrophysiology procedures. We aimed to test the feasibility and safety of a zero-fluoroscopic strategy using a novel integrated magnetic and impedance-based electroanatomical mapping system for radiofrequency ablation (RFA) of supraventricular tachycardias (SVTs). We retrospectively studied 92 consecutive patients undergoing electrophysiology studies with/without RFA for supraventricular tachycardia (SVT) performed by a single operator at a single center. The first 42 (Group 1) underwent a conventional fluoroscopic-guided approach and the second 50 (Group 2) underwent a zero-fluoroscopic approach using the Ensite Precision ™ 3-D magnetic and impedance-based mapping system (Abbott Inc). Group 1 comprised 14 AV-nodal re-entrant tachycardia (AVNRT), 12 typical atrial flutter, 4 accessory pathway (AP), 2 atrial tachycardia (AT), and 9 diagnostic EP studies (EPS). Group 2 comprised 16 AVNRT, 17 atrial flutter, 6 AP, 3 AT, 2 AV-nodal ablations, and 7 EPS. A complete zero-fluoroscopic approach was achieved in 94% of Group 2 patients. All procedures were acutely successful, and no complications occurred. There was a significant reduction in fluoroscopy dose, dose area product, and time (p < 0.0001, for all), with no difference in procedure times. Ablation time for typical atrial flutter was shorter in Group 2 (p = 0.006). A zero-fluoroscopic strategy for diagnosis and treatment of SVTs using this novel 3D-electroanatomical mapping system is feasible in majority of patients, is safe, reduces ionizing radiation exposure, and does not compromise procedural times, success rates, or complication rates.
Xu, Q Y; Yin, G W; Chen, S X; Jiang, F; Bai, X J; Wu, J D
2012-11-01
The aim of this study was to retrospectively evaluate the technical success rates and clinical effectiveness of fluoroscopically guided nose tube drainage of mediastinal abscesses and a nasojejunum feeding tube in post-operative gastro-oesophageal anastomotic leakage (GEAL). From January 2006 to June 2011, 18 cases of post-operative GEAL with mediastinal abscesses after oesophagectomy with intrathoracic oesophagogastric anastomotic procedures for oesophageal and cardiac carcinoma were treated by insertion of a nose drainage tube and nasojejunum feeding tube under fluoroscopic guidance. We evaluated the feasibility of two-tube insertion to facilitate leakage site closure and complete resolution of the abscess, and the patients' nutritional benefit was also evaluated by checking the serum albumin level between pre- and post-enteral feeding via the feeding tube. The two tubes were placed successfully under fluoroscopic guidance in 18 patients (100%). The procedure time for two-tube insertion ranged from 20 to 40 min (mean 30 min). 17 patients (94%) achieved leakage site closure after two-tube insertion and had a good tolerance of two tubes in the nasal cavity. The serum albumin level was significant, increased from pre-enteral feeding (2.49 ± 0.42 g dl(-1)) to the post-enteral feeding (3.58 ± 0.47 g dl(-1)) via the feeding tube (p<0.001). The duration of follow-up ranged from 1 to 49 months (mean 19 months). The insertion of nose tube drainage and a nasojejunum feeding tube under fluoroscopic guidance is safe, and it provides effective relief from mediastinal abscesses in GEAL after oesophagectomy. Moreover, our findings indicate that two-tube insertion may be used as a selective procedure to treat mediastinal abscesses in post-operative GEAL. Advances in knowledge Directive drainage of mediastinal abscesses in post-operative GEAL may be an effective treatment.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xiong, Z; Vijayan, S; Oines, A
Purpose: To compare PCXMC and EGSnrc calculated organ and effective radiation doses from cone-beam computed tomography (CBCT) and interventional fluoroscopically-guided procedures using automatic exposure-event grouping. Methods: For CBCT, we used PCXMC20Rotation.exe to automatically calculate the doses and compared the results to those calculated using EGSnrc with the Zubal patient phantom. For interventional procedures, we use the dose tracking system (DTS) which we previously developed to produce a log file of all geometry and exposure parameters for every x-ray pulse during a procedure, and the data in the log file is input into PCXMC and EGSnrc for dose calculation. A MATLABmore » program reads data from the log files and groups similar exposures to reduce calculation time. The definition files are then automatically generated in the format used by PCXMC and EGSnrc. Processing is done at the end of the procedure after all exposures are completed. Results: For the Toshiba Infinix CBCT LCI-Middle-Abdominal protocol, most organ doses calculated with PCXMC20Rotation closely matched those calculated with EGSnrc. The effective doses were 33.77 mSv with PCXMC20Rotation and 32.46 mSv with EGSnrc. For a simulated interventional cardiac procedure, similar close agreement in organ dose was obtained between the two codes; the effective doses were 12.02 mSv with PCXMC and 11.35 mSv with EGSnrc. The calculations can be completed on a PC without manual intervention in less than 15 minutes with PCXMC and in about 10 hours with EGSnrc, depending on the level of data grouping and accuracy desired. Conclusion: Effective dose and most organ doses in CBCT and interventional radiology calculated by PCXMC closely match those calculated by EGSnrc. Data grouping, which can be done automatically, makes the calculation time with PCXMC on a standard PC acceptable. This capability expands the dose information that can be provided by the DTS. Partial support from NIH Grant R01-EB002873 and Toshiba Medical Systems Corp.« less
C-arm positioning using virtual fluoroscopy for image-guided surgery
NASA Astrophysics Data System (ADS)
de Silva, T.; Punnoose, J.; Uneri, A.; Goerres, J.; Jacobson, M.; Ketcha, M. D.; Manbachi, A.; Vogt, S.; Kleinszig, G.; Khanna, A. J.; Wolinsky, J.-P.; Osgood, G.; Siewerdsen, J. H.
2017-03-01
Introduction: Fluoroscopically guided procedures often involve repeated acquisitions for C-arm positioning at the cost of radiation exposure and time in the operating room. A virtual fluoroscopy system is reported with the potential of reducing dose and time spent in C-arm positioning, utilizing three key advances: robust 3D-2D registration to a preoperative CT; real-time forward projection on GPU; and a motorized mobile C-arm with encoder feedback on C-arm orientation. Method: Geometric calibration of the C-arm was performed offline in two rotational directions (orbit α, orbit β). Patient registration was performed using image-based 3D-2D registration with an initially acquired radiograph of the patient. This approach for patient registration eliminated the requirement for external tracking devices inside the operating room, allowing virtual fluoroscopy using commonly available systems in fluoroscopically guided procedures within standard surgical workflow. Geometric accuracy was evaluated in terms of projection distance error (PDE) in anatomical fiducials. A pilot study was conducted to evaluate the utility of virtual fluoroscopy to aid C-arm positioning in image guided surgery, assessing potential improvements in time, dose, and agreement between the virtual and desired view. Results: The overall geometric accuracy of DRRs in comparison to the actual radiographs at various C-arm positions was PDE (mean ± std) = 1.6 ± 1.1 mm. The conventional approach required on average 8.0 ± 4.5 radiographs spent "fluoro hunting" to obtain the desired view. Positioning accuracy improved from 2.6o ± 2.3o (in α) and 4.1o ± 5.1o (in β) in the conventional approach to 1.5o ± 1.3o and 1.8o ± 1.7o, respectively, with the virtual fluoroscopy approach. Conclusion: Virtual fluoroscopy could improve accuracy of C-arm positioning and save time and radiation dose in the operating room. Such a system could be valuable to training of fluoroscopy technicians as well as intraoperative use in fluoroscopically guided procedures.
Zhao, Kristin D.; Ben-Abraham, Ephraim I.; Magnuson, Dixon J.; Camp, Jon J.; Berglund, Lawrence J.; An, Kai-Nan; Bronfort, Gert; Gay, Ralph E.
2016-01-01
Spine intersegmental motion parameters and the resultant regional patterns may be useful for biomechanical classification of low back pain (LBP) as well as assessing the appropriate intervention strategy. Because of its availability and reasonable cost, two-dimensional (2D) fluoroscopy has great potential as a diagnostic and evaluative tool. However, the technique of quantifying intervertebral motion in the lumbar spine must be validated, and the sensitivity assessed. The purpose of this investigation was to (1) compare synchronous fluoroscopic and optoelectronic measures of intervertebral rotations during dynamic flexion–extension movements in vitro and (2) assess the effect of C-arm rotation to simulate off-axis patient alignment on intervertebral kinematics measures. Six cadaveric lumbar–sacrum specimens were dissected, and active marker optoelectronic sensors were rigidly attached to the bodies of L2–S1. Fluoroscopic sequences and optoelectronic kinematic data (0.15-mm linear, 0.17–0.20 deg rotational, accuracy) were obtained simultaneously. After images were obtained in a true sagittal plane, the image receptor was rotated in 5 deg increments (posterior oblique angulations) from 5 deg to 15 deg. Quantitative motion analysis (qma) software was used to determine the intersegmental rotations from the fluoroscopic images. The mean absolute rotation differences between optoelectronic values and dynamic fluoroscopic values were less than 0.5 deg for all the motion segments at each off-axis fluoroscopic rotation and were not significantly different (P > 0.05) for any of the off-axis rotations of the fluoroscope. Small misalignments of the lumbar spine relative to the fluoroscope did not introduce measurement variation in relative segmental rotations greater than that observed when the spine and fluoroscope were perpendicular to each other, suggesting that fluoroscopic measures of relative segmental rotation during flexion–extension are likely robust, even when patient alignment is not perfect. PMID:26974192
Zhao, Kristin D; Ben-Abraham, Ephraim I; Magnuson, Dixon J; Camp, Jon J; Berglund, Lawrence J; An, Kai-Nan; Bronfort, Gert; Gay, Ralph E
2016-05-01
Spine intersegmental motion parameters and the resultant regional patterns may be useful for biomechanical classification of low back pain (LBP) as well as assessing the appropriate intervention strategy. Because of its availability and reasonable cost, two-dimensional (2D) fluoroscopy has great potential as a diagnostic and evaluative tool. However, the technique of quantifying intervertebral motion in the lumbar spine must be validated, and the sensitivity assessed. The purpose of this investigation was to (1) compare synchronous fluoroscopic and optoelectronic measures of intervertebral rotations during dynamic flexion-extension movements in vitro and (2) assess the effect of C-arm rotation to simulate off-axis patient alignment on intervertebral kinematics measures. Six cadaveric lumbar-sacrum specimens were dissected, and active marker optoelectronic sensors were rigidly attached to the bodies of L2-S1. Fluoroscopic sequences and optoelectronic kinematic data (0.15-mm linear, 0.17-0.20 deg rotational, accuracy) were obtained simultaneously. After images were obtained in a true sagittal plane, the image receptor was rotated in 5 deg increments (posterior oblique angulations) from 5 deg to 15 deg. Quantitative motion analysis (qma) software was used to determine the intersegmental rotations from the fluoroscopic images. The mean absolute rotation differences between optoelectronic values and dynamic fluoroscopic values were less than 0.5 deg for all the motion segments at each off-axis fluoroscopic rotation and were not significantly different (P > 0.05) for any of the off-axis rotations of the fluoroscope. Small misalignments of the lumbar spine relative to the fluoroscope did not introduce measurement variation in relative segmental rotations greater than that observed when the spine and fluoroscope were perpendicular to each other, suggesting that fluoroscopic measures of relative segmental rotation during flexion-extension are likely robust, even when patient alignment is not perfect.
Outcome of Percutaneous Lumbar Synovial Cyst Rupture in Patients with Lumbar Radiculopathy.
Eshraghi, Yashar; Desai, Vimal; Cajigal Cajigal, Calvin; Tabbaa, Kutaiba
2016-01-01
Lumbar synovial cysts can result from spondylosis of facet joints. These cysts can encroach on adjacent nerve roots, causing symptoms of radiculopathy. Currently the only definitive treatment for these symptoms is surgery, which may involve laminectomy or laminotomy, with or without spinal fusion. Surgery has been reported to successfully relieve radicular pain in 83.5% of patients by Zhenbo et al. Little information is available concerning the efficacy and outcome of percutaneous fluoroscopic synovial cyst rupture for treatment of facet joint synovial cysts. The goal of this investigation was to assess the efficacy of fluoroscopically guided lumbar synovial cyst rupture, in particular for its relief of radicular symptoms and its potential to reduce the need for surgical intervention. Retrospective evaluation of a case series. University hospital and urban public health care system. With approval from the Institutional Review Board of Case Western Reserve University/ MetroHealth Medical Center, we reviewed the medical charts of patients with lumbar radiculopathy who underwent percutaneous lumbar synovial cyst rupture. The 30 patients in the cohort were treated by one pain specialist between 2006 and 2013. These patients were diagnosed with moderate to severe lower back pain, radiculopathy, and ranged in age from 42 to 80 years. Patients were followed up for a minimum of 6 months and up to 24 months. Pre- and post-procedure pain assessments were reviewed by clinical chart review. In addition post-procedure pain assessments and duration of pain relief were obtained with telephone interviews. Pain had been reported by the patients using a numeric rating scale of 0 - 10 (0 = no pain; 10 = worst possible pain). Charts were reviewed to determine if surgery was eventually performed to correct radicular symptoms. More than 6 months of pain relief was achieved in 14/30 patients (46%) and between one and 6 months of pain relief was achieved in 7/30 patients (23.3%). Nine patients (30.0%) had recurrence of the synovial cyst requiring repeat rupture and 6 patients (20.0%) required surgical intervention for cyst removal. A Wilcoxon signed-rank test demonstrated that the difference in numeric pain rating scale scores before and after the procedure was statistically significant (P < 0.0001). The average pain reduction was 71.2%. No complications were reported. The results are limited by the retrospective nature of the data collection and the lack of detailed information regarding patients' functional improvement. Rupture of percutaneous lumbar synovial cysts in patients with lumbar radiculopathy was associated with immediate relief of radicular symptoms. In 80% of the patients, synovial cyst rupture eliminated the need for surgical interventions over the measured term. This minimally invasive procedure helps relieve pain in a subset of a patient population associated with these characteristics and is useful for management of this condition. Cyst expansion and failure to rupture with possible neuronal compression are the potential complications of this procedure. This complication did not occur in the study population. Fluoroscopically guided lumbar synovial cyst rupture, lumbar synovial cyst, lumbar zygapophyseal joint cyst, nonsurgical intervention, radiculopathy, spondylosis.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Morikawa, Shigehiro, E-mail: morikawa@belle.shiga-med.ac.jp; Inubushi, Toshiro; Kurumi, Yoshimasa
2004-08-15
We obtained clear and reproducible MR fluoroscopic images and temperature maps for MR image-guided microwave ablation of liver tumors under general anesthesia without suspending the artificial ventilation. Respiratory information was directly obtained from air-way pressure without a sensor on the chest wall. The trigger signal started scanning of one whole image with a spoiled gradient echo sequence. The delay time before the start of scanning was adjusted to acquire the data corresponding to the k-space center at the maximal expiratory phase. The triggered images were apparently clearer than the nontriggered ones and the location of the liver was consistent, whichmore » made targeting of the tumor easy. MR temperature images, which were highly susceptible to the movement of the liver, during microwave ablation using a proton resonance frequency method, could be obtained without suspending the artificial ventilation. Respiratory triggering technique was found to be useful for MR fluoroscopic images and MR temperature monitoring in MR-guided microwave ablation of liver tumors under general anesthesia.« less
DeGregoris, Gerard; Diwan, Sudhir
2010-01-01
Lower back and extremity pain in the amputee patient can be challenging to classify and treat. Radicular compression in a patient with lower limb amputation may present as or be superimposed upon phantom limb pain, creating diagnostic difficulties. Both patients and physicians classically find it difficult to discern phantom sensation from phantom limb pain and stump pain; radicular compression is often not considered. Many studies have shown back pain to be a significant cause of pain in lower limb amputees, but sciatica has been rarely reported in amputees. We present a case of L4/5 radiculitis in an above-knee amputee presenting as phantom radiculitis. Our patient is a 67 year old gentleman with new onset 10/10 pain in a phantom extremity superimposed upon a 40 year history of previously stable phantom limb pain. MRI showed a central disc herniation at L4/5 with compression of the traversing left L4 nerve root. Two fluoroscopically guided left transforaminal epidural steroid injections at the level of the L4 and L5 spinal nerve roots totally alleviated his new onset pain. At one year post injection, his phantom radiculitis pain was completely gone, though his underlying phantom limb pain remained. Lumbar radiculitis in lower extremity amputee patients may be difficult to differentiate from baseline phantom limb pain. When conservative techniques fail, fluoroscopically guided spinal nerve injection may be valuable in determining the etiology of lower extremity pain. Our experience supports the notion that epidural steroid injections can effectively treat phantom lumbar radiculitis in lower extremity amputees.
NASA Astrophysics Data System (ADS)
Tanaka, Rie; Sanada, Shigeru; Sakuta, Keita; Kawashima, Hiroki
2015-05-01
The bone suppression technique based on advanced image processing can suppress the conspicuity of bones on chest radiographs, creating soft tissue images obtained by the dual-energy subtraction technique. This study was performed to evaluate the usefulness of bone suppression image processing in image-guided radiation therapy. We demonstrated the improved accuracy of markerless motion tracking on bone suppression images. Chest fluoroscopic images of nine patients with lung nodules during respiration were obtained using a flat-panel detector system (120 kV, 0.1 mAs/pulse, 5 fps). Commercial bone suppression image processing software was applied to the fluoroscopic images to create corresponding bone suppression images. Regions of interest were manually located on lung nodules and automatic target tracking was conducted based on the template matching technique. To evaluate the accuracy of target tracking, the maximum tracking error in the resulting images was compared with that of conventional fluoroscopic images. The tracking errors were decreased by half in eight of nine cases. The average maximum tracking errors in bone suppression and conventional fluoroscopic images were 1.3 ± 1.0 and 3.3 ± 3.3 mm, respectively. The bone suppression technique was especially effective in the lower lung area where pulmonary vessels, bronchi, and ribs showed complex movements. The bone suppression technique improved tracking accuracy without special equipment and implantation of fiducial markers, and with only additional small dose to the patient. Bone suppression fluoroscopy is a potential measure for respiratory displacement of the target. This paper was presented at RSNA 2013 and was carried out at Kanazawa University, JAPAN.
Greffier, J; Van Ngoc Ty, C; Bonniaud, G; Moliner, G; Ledermann, B; Schmutz, L; Cornillet, L; Cayla, G; Beregi, J P; Pereira, F
2017-06-01
To compare the use of a dose mapping software to Gafchromic film measurement for a simplified peak skin dose (PSD) estimation in interventional cardiology procedure. The study was conducted on a total of 40 cardiac procedures (20 complex coronary angioplasty of chronic total occlusion (CTO) and 20 coronary angiography and coronary angioplasty (CA-PTCA)) conducted between January 2014 to December 2015. PSD measurement (PSD Film ) was obtained by placing XR-RV3 Gafchromic under the patient's back for each procedure. PSD (PSD em.dose ) was computed with the software em.dose©. The calculation was performed on the dose metrics collected from the private dose report of each procedure. Two calculation methods (method A: fluoroscopic kerma equally spread on cine acquisition and B: fluoroscopic kerma is added to one air Kerma cine acquisition that contributes to the PSD) were used to calculate the fluoroscopic dose contribution as fluoroscopic data were not recorded in our interventional room. Statistical analyses were carried out to compare PSD Film and PSD em.dose . The PSD Film median (1st quartile; 3rd quartile) was 0.251(0.190;0.336)Gy for CA-PTCA and 1.453(0.767;2.011)Gy for CTO. For method-A, the PSD em.dose was 0.248(0.182;0.369)Gy for CA-PTCA and 1.601(0.892;2.178)Gy for CTO, and 0.267(0.223;0.446)Gy and 1.75 (0.912;2.584)Gy for method-B, respectively. For the two methods, the correlation between PSD Film and PSD em.dose was strong. For all cardiology procedures investigated, the mean deviation between PSD Film and PSD em.dose was 3.4±21.1% for method-A and 17.3%±23.9% for method-B. The dose mapping software is convenient to calculate peak skin dose in interventional cardiology. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
Mendiratta-Lala, Mishal; Williams, Todd R; Mendiratta, Vivek; Ahmed, Hafeez; Bonnett, John W
2015-04-01
The purpose of this study was to evaluate the effectiveness of a multifaceted simulation-based resident training for CT-guided fluoroscopic procedures by measuring procedural and technical skills, radiation dose, and procedure times before and after simulation training. A prospective analysis included 40 radiology residents and eight staff radiologists. Residents took an online pretest to assess baseline procedural knowledge. Second-through fourth-year residents' baseline technical skills with a procedural phantom were evaluated. First-through third-year residents then underwent formal didactic and simulation-based procedural and technical training with one of two interventional radiologists and followed the training with 1 month of supervised phantom-based practice. Thereafter, residents underwent final written and practical examinations. The practical examination included essential items from a 20-point checklist, including site and side marking, consent, time-out, and sterile technique along with a technical skills portion assessing pedal steps, radiation dose, needle redirects, and procedure time. The results indicated statistically significant improvement in procedural and technical skills after simulation training. For residents, the median number of pedal steps decreased by three (p=0.001), median dose decreased by 15.4 mGy (p<0.001), median procedure time decreased by 4.0 minutes (p<0.001), median number of needle redirects decreased by 1.0 (p=0.005), and median number of 20-point checklist items successfully completed increased by three (p<0.001). The results suggest that procedural skills can be acquired and improved by simulation-based training of residents, regardless of experience. CT simulation training decreases procedural time, decreases radiation dose, and improves resident efficiency and confidence, which may transfer to clinical practice with improved patient care and safety.
Silicon sensors for catheters and guide wires
NASA Astrophysics Data System (ADS)
Goosen, Hans F.
2001-11-01
One area that can make use of the miniature size of present day micro electromechanical systems (MEMS) is that of the medical field of minimally invasive interventions. These procedures, used for both diagnosis and treatment, use catheters that are advanced through the blood vessels deep into the body, without the need for surgery. However, once inside the body, the doctor performing the procedure is completely reliant on the information the catheter(s) can provide in addition to the projection imaging of a fluoroscope. A good range of sensors for catheters is required for a proper diagnosis. To this end, miniature sensors are being developed to be fitted to catheters and guide wires. As the accurate positioning of these instruments is problematic, it is necessary to combine several sensors on the same guide wire or catheter to measure several parameters in the same location. This however, brings many special problems to the design of the sensors, such as small size, low power consumption, bio-compatibility of materials, robust design for patient safety, a limited number of connections, packaging, etc. This paper will go into both the advantages and design problems of micromachined sensors and actuators in catheters and guide wires. As an example, a multi parameter blood sensor, measuring flow velocity, pressure and oxygen saturation, will be discussed.
Right ventricular septal pacing: the success of stylet-driven active-fixation leads.
Rosso, Raphael; Teh, Andrew W; Medi, Caroline; Hung, Thuy To; Balasubramaniam, Richard; Mond, Harry G
2010-01-01
The detrimental effects of right ventricular (RV) apical pacing on left ventricular function has driven interest in alternative pacing sites and in particular the mid RV septum and RV outflow tract (RVOT). RV septal lead positioning can be successfully achieved with a specifically shaped stylet and confirmed by the left anterior oblique (LAO) fluoroscopic projection. Such a projection is neither always used nor available during pacemaker implantation. The aim of this study was to evaluate how effective is the stylet-driven technique in septal lead placement guided only by posterior-anterior (PA) fluoroscopic view. One hundred consecutive patients with an indication for single- or dual-chamber pacing were enrolled. RV septal lead positioning was attempted in the PA projection only and confirmed by the LAO projection at the end of the procedure. The RV lead position was septal in 90% of the patients. This included mid RV in 56 and RVOT in 34 patients. There were no significant differences in the mean stimulation threshold, R-wave sensing, and lead impedance between the two sites.In the RVOT, 97% (34/35) of leads were placed on the septum, whereas in the mid RV the value was 89% (56/63). The study confirms that conventional active-fixation pacing leads can be successfully and safely deployed onto the RV septum using a purposely-shaped stylet guided only by the PA fluoroscopic projection.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wunderle, K; Wayne State University School of Medicine, Detroit, MI; Godley, A
Purpose: The purpose of this investigation was to quantify percent depth dose (PDD) curves for fluoroscopic x-ray beam qualities incorporating added copper filtration. Methods: A PTW (Freiburg, Germany) MP3 water tank was used with a Standard Imaging (Middleton, WI) Exradin Model 11 Spokas Chamber to measure PDD curves for 60, 80, 100 and 120 kVp x-ray beams with copper filtration ranging from 0.0–0.9 mm at 22cm and 42cm fields of view from 0 to 150 mm of water. A free-in-air monitor chamber was used to normalize the water tank data to fluctuations in output from the fluoroscope. The measurements weremore » acquired on a Siemens (Erlangen, Germany) Artis ZeeGo fluoroscope. The fluoroscope was inverted from the typical orientation providing an x-ray beam originating from above the water tank. The water tank was positioned so that the water level was located at 60cm from the focal spot; which also represents the focal spot to interventional reference plane distance for that fluoroscope. Results: PDDs for 60, 80, 100, and 120 kVp with 0 mm of copper filtration compared well to previously published data by Fetterly et al. [Med Phys, 28, 205 (2001)] for those beam qualities given differences in fluoroscopes, geometric orientation, type of ionization chamber, and the water tank used for data collection. PDDs for 60, 80, 100, and 120 kVp with copper filtration were obtained and are presented, which have not been previously investigated and published. Conclusion: The equipment and processes used to acquire the reported data were sound and compared well with previously published data for PDDs without copper filtration. PDD data for the fluoroscopic x-ray beams incorporating copper filtration can be used as reference data for estimating organ or soft tissue dose at depth involving similar beam qualities or for comparison with mathematical models.« less
Ultrasound-guided suprascapular nerve block: a correlation with fluoroscopic and cadaveric findings.
Peng, Philip W H; Wiley, Michael J; Liang, James; Bellingham, Geoff A
2010-02-01
Previous work on the ultrasound-guided injection technique and the sonoanatomy of the suprascapular region relevant to the suprascapular nerve (SSN) block suggested that the ultrasound scan showed the presence of the suprascapular notch and transverse ligament. The intended target of the ultrasound-guided injection was the notch. The objective of this case report and the subsequent cadaver dissection findings is to reassess the interpretation of the ultrasound images when locating structures for SSN block. A 45-yr-old man with chronic shoulder pain received an ultrasound-guided SSN block using the suprascapular notch as the intended target. The position of the needle was verified by fluoroscopy, which showed the tip of the needle well outside the suprascapular notch. Similar ultrasound-guided SSN blocks were performed in two cadavers. Dissections were performed which showed that the needle tips were not at the suprascapular notch but, more accurately, were close to the SSN but at the floor of the suprascapular fossa between the suprascapular and spinoglenoid notch. Our fluoroscopic and cadaver dissection findings both suggest that the ultrasound image of the SSN block shown by the well-described technique is actually targeting the nerve on the floor of the suprascapular spine between the suprascapular and spinoglenoid notches rather than the suprascapular notch itself. The structure previously identified as the transverse ligament is actually the fascia layer of the supraspinatus muscle.
Hashimoto, Sho; Takahashi, Akihiko; Yamada, Takeshi; Mizuguchi, Yukio; Taniguchi, Norimasa; Hata, Tetsuya; Nakajima, Shunsuke
2017-11-20
The extension support guiding catheter has been used to perform complex percutaneous coronary intervention to increase back-up support for the guiding catheter or to ensure deep intubation for device delivery. However, because of its monorail design, advancement of the stent into the distal extension tubing segment is sometimes problematic. Although this problem is considered due to simple collision of the stent, operators have observed tangling between a monorail extension catheter and coronary guidewire in some patients. To examine movement of the collar of the extension guide catheter during advancement of the guiding catheter, we set up an in vitro model in which the guiding catheter had two curves. Rotation of the extension guide catheter was examined by both fluoroscopic imaging and movement of the hub of the proximal end of the catheter. During advancement in the first curve, the collar moved toward the outer side of the curve of the guiding catheter as the operator pushed the shaft of the extension guiding catheter, which overrode the guidewire. After crossing the first curve, the collar moved again to the outer side of the second curve (the inner side of the first curve) of the mother catheter, and then, another clockwise rotation was observed in the proximal hub. Consequently, the collar and tubing portion of the extension guide catheter rotated 360° around the coronary guidewire, and the monorail extension catheter and guidewire became tangled. There is a potential risk of unintentional twisting with the guidewire during advancement into the curved guiding catheter because of its monorail design.
Video-guided calibration of an augmented reality mobile C-arm.
Chen, Xin; Naik, Hemal; Wang, Lejing; Navab, Nassir; Fallavollita, Pascal
2014-11-01
The augmented reality (AR) fluoroscope augments an X-ray image by video and provides the surgeon with a real-time in situ overlay of the anatomy. The overlay alignment is crucial for diagnostic and intra-operative guidance, so precise calibration of the AR fluoroscope is required. The first and most complex step of the calibration procedure is the determination of the X-ray source position. Currently, this is achieved using a biplane phantom with movable metallic rings on its top layer and fixed X-ray opaque markers on its bottom layer. The metallic rings must be moved to positions where at least two pairs of rings and markers are isocentric in the X-ray image. The current "trial and error" calibration process currently requires acquisition of many X-ray images, a task that is both time consuming and radiation intensive. An improved process was developed and tested for C-arm calibration. Video guidance was used to drive the calibration procedure to minimize both X-ray exposure and the time involved. For this, a homography between X-ray and video images is estimated. This homography is valid for the plane at which the metallic rings are positioned and is employed to guide the calibration procedure. Eight users having varying calibration experience (i.e., 2 experts, 2 semi-experts, 4 novices) were asked to participate in the evaluation. The video-guided technique reduced the number of intra-operative X-ray calibration images by 89% and decreased the total time required by 59%. A video-based C-arm calibration method has been developed that improves the usability of the AR fluoroscope with a friendlier interface, reduced calibration time and clinically acceptable radiation doses.
Compagnone, Gaetano; Padovani, Renato; D'Avanzo, Maria Antonietta; Grande, Sveva; Campanella, Francesco; Rosi, Antonella
2018-05-01
A Working Group coordinated by the Italian National Institute of Health (Istituto Superiore di Sanità) and the National Workers Compensation Authority (Istituto Nazionale per l'Assicurazione contro gli Infortuni sul Lavoro, INAIL) and consisting of 11 Italian scientific/professional societies involved in the fluoroscopically guided interventional practices has been established to define recommendations for the optimization of patients and staff radiation protection in interventional radiology. A summary of these recommendations is here reported. A multidisciplinary approach was used to establish the Working Group by involving radiologists, interventional radiologists, neuroradiologists, interventional cardiologists, occupational health specialists, medical physicists, radiation protection experts, radiographers and nurses. The Group operated as a "Consensus Conference". Three main topics have been addressed: patient radiation protection (summarized in ten "golden rules"); staff radiation protection (summarized in ten "golden rules"); and education/training of interventional radiology professionals. In the "golden rules", practical and operational recommendations were provided to help the professionals in optimizing dose delivered to patients and reducing their own exposure. Operative indications dealt also with continuing education and training, and recommendations on professional accreditation and certification. The "Consensus Conference" was the methodology adopted for the development of these recommendations. Involvement of all professionals is a winning approach to improve practical implementation of the recommendations, thus getting a real impact on the optimization of the interventional radiology practices.
Arujuna, Aruna V; Housden, R James; Ma, Yingliang; Rajani, Ronak; Gao, Gang; Nijhof, Niels; Cathier, Pascal; Bullens, Roland; Gijsbers, Geert; Parish, Victoria; Kapetanakis, Stamatis; Hancock, Jane; Rinaldi, C Aldo; Cooklin, Michael; Gill, Jaswinder; Thomas, Martyn; O'neill, Mark D; Razavi, Reza; Rhode, Kawal S
2014-01-01
Real-time imaging is required to guide minimally invasive catheter-based cardiac interventions. While transesophageal echocardiography allows for high-quality visualization of cardiac anatomy, X-ray fluoroscopy provides excellent visualization of devices. We have developed a novel image fusion system that allows real-time integration of 3-D echocardiography and the X-ray fluoroscopy. The system was validated in the following two stages: 1) preclinical to determine function and validate accuracy; and 2) in the clinical setting to assess clinical workflow feasibility and determine overall system accuracy. In the preclinical phase, the system was assessed using both phantom and porcine experimental studies. Median 2-D projection errors of 4.5 and 3.3 mm were found for the phantom and porcine studies, respectively. The clinical phase focused on extending the use of the system to interventions in patients undergoing either atrial fibrillation catheter ablation (CA) or transcatheter aortic valve implantation (TAVI). Eleven patients were studied with nine in the CA group and two in the TAVI group. Successful real-time view synchronization was achieved in all cases with a calculated median distance error of 2.2 mm in the CA group and 3.4 mm in the TAVI group. A standard clinical workflow was established using the image fusion system. These pilot data confirm the technical feasibility of accurate real-time echo-fluoroscopic image overlay in clinical practice, which may be a useful adjunct for real-time guidance during interventional cardiac procedures.
Iatrogenic deep musculocutaneous radiation injury following percutaneous coronary intervention.
Monaco, JoAn L; Bowen, Kanika; Tadros, Peter N; Witt, Peter D
2003-08-01
Radiation-induced skin injury has been reported for multiple fluoroscopic procedures. Previous studies have indicated that prolonged fluoroscopic exposure during even a single percutaneous coronary intervention (PCI) may lead to cutaneous radiation injury. We document a novel case of deep muscle damage requiring wide local debridement and muscle flap reconstruction in a 59-year-old man with a large radiation-induced wound to the lower thoracic region following 1 prolonged PCI procedure. The deep muscular iatrogenic injury described in this report may be the source of significant morbidity. Recommendations to reduce radiation-induced damage include careful examination of the skin site before each procedure, minimized fluoroscopy time, utilization of pulse fluoroscopy, employment of radiation filters, and collimator s and rotation of the location of the image intensifier.
Kennedy, David J.; Schneider, Byron; Casey, Ellen; Rittenberg, Joshua; Conrad, Bryan; Smuck, Matthew; Plastaras, Christopher T.
2014-01-01
Objective To determine the rate of vasovagal (vv) complications in fluoroscopically guided interventional procedures. Design Retrospective case series analysis of prospectively collected data from March 8, 2004 to January 30, 2009. Setting A single academic medical center. Subjects Four thousand one hundred eighty-three subjects undergoing 8,010 consecutive injections. Outcome Measures Pearson's chi-square test was used to determine the relationship between categorical variables. Results A total of 8,010 injections, including epidural steroid injections, radiofrequency nerve ablations, medial branch blocks, hip injections, knee injections, and glenohumeral injections were performed. Overall vv reaction rate was 2.6%, with 0.8% of procedures resulting in early terminated due to vv reaction. Peripheral joint injections had a vv rate of 0.2%, all occurring in hip injections. Transforaminal epidural steroid injections had a vv rate of 3.5%. Diagnostic blocks of the medial branches had the highest rate of vv (5.1%). Other predictors of vv reactions were identified including preprocedure pain score visual analog scale <5 (P = 0.004), male gender (P < 0.001), and age less than 65 years old (P < 0.001). Conclusions vv reactions have an overall low occurrence rate (2.6%) in interventional procedures ranging from 0% in peripheral knee and shoulder injections to 5.1% in medial branch blocks. Conservative treatment of vv reaction and willingness to terminate procedures resulted in no serious adverse events related to vv reaction in 8,010 procedures. PMID:24118835
van Duren, B H; Sugand, K; Wescott, R; Carrington, R; Hart, A
2018-05-01
Hip fractures contribute to a significant clinical burden globally with over 1.6 million cases per annum and up to 30% mortality rate within the first year. Insertion of a dynamic hip screw (DHS) is a frequently performed procedure to treat extracapsular neck of femur fractures. Poorly performed DHS fixation of extracapsular neck of femur fractures can result in poor mobilisation, chronic pain, and increased cut-out rate requiring revision surgery. A realistic, affordable, and portable fluoroscopic simulation system can improve performance metrics in trainees, including the tip-apex distance (the only clinically validated outcome), and improve outcomes. We developed a digital fluoroscopic imaging simulator using orthogonal cameras to track coloured markers attached to the guide-wire which created a virtual overlay on fluoroscopic images of the hip. To test the accuracy with which the augmented reality system could track a guide-wire, a standard workshop femur was used to calibrate the system with a positional marker fixed to indicate the apex; this allowed for comparison between guide-wire tip-apex distance (TAD) calculated by the system to be compared to that physically measured. Tests were undertaken to determine: (1) how well the apex could be targeted; (2) the accuracy of the calculated TAD. (3) The number of iterations through the algorithm giving the optimal accuracy-time relationship. The calculated TAD was found to have an average root mean square error of 4.2 mm. The accuracy of the algorithm was shown to increase with the number of iterations up to 20 beyond which the error asymptotically converged to an error of 2 mm. This work demonstrates a novel augmented reality simulation of guide-wire insertion in DHS surgery. To our knowledge this has not been previously achieved. In contrast to virtual reality, augmented reality is able to simulate fluoroscopy while allowing the trainee to interact with real instrumentation and performing the procedure on workshop bone models. Copyright © 2018 IPEM. Published by Elsevier Ltd. All rights reserved.
Intravascular US-Guided Portal Vein Access: Improved Procedural Metrics during TIPS Creation.
Gipson, Matthew G; Smith, Mitchell T; Durham, Janette D; Brown, Anthony; Johnson, Thor; Ray, Charles E; Gupta, Rajan K; Kondo, Kimi L; Rochon, Paul J; Ryu, Robert K
2016-08-01
To evaluate transjugular intrahepatic portosystemic shunt (TIPS) outcomes and procedure metrics with the use of three different image guidance techniques for portal vein (PV) access during TIPS creation. A retrospective review of consecutive patients who underwent TIPS procedures for a range of indications during a 28-month study period identified a population of 68 patients. This was stratified by PV access techniques: fluoroscopic guidance with or without portography (n = 26), PV marker wire guidance (n = 18), or intravascular ultrasound (US) guidance (n = 24). Procedural outcomes and procedural metrics, including radiation exposure, contrast agent volume used, procedure duration, and PV access time, were analyzed. No differences in demographic or procedural characteristics were found among the three groups. Technical success, technical success of the primary planned approach, hemodynamic success, portosystemic gradient, and procedure-related complications were not significantly different among groups. Fluoroscopy time (P = .003), air kerma (P = .01), contrast agent volume (P = .003), and total procedural time (P = .02) were reduced with intravascular US guidance compared with fluoroscopic guidance. Fluoroscopy time (P = .01) and contrast agent volume (P = .02) were reduced with intravascular US guidance compared with marker wire guidance. Intravascular US guidance of PV access during TIPS creation not only facilitates successful TIPS creation in patients with challenging anatomy, as suggested by previous investigations, but also reduces important procedure metrics including radiation exposure, contrast agent volume, and overall procedure duration compared with fluoroscopically guided TIPS creation. Copyright © 2016 SIR. Published by Elsevier Inc. All rights reserved.
Toward computer-assisted image-guided congenital heart defect repair: an initial phantom analysis.
Kwartowitz, David M; Mefleh, Fuad N; Baker, G Hamilton
2017-10-01
Radiation exposure in interventional cardiology is an important consideration, due to risk of cancer and other morbidity to the patient and clinical staff. Cardiac catheterizations rely heavily on fluoroscopic imaging exposing both patient and clinician to ionizing radiation. An image-guided surgery system capable of facilitating cardiac catheterizations was developed and tested to evaluate dose reduction. Several electromagnetically tracked tools were constructed specifically a 7-Fr catheter with five 5-degree-of-freedom magnetic seeds. Catheter guidance was accomplished using our image guidance system Kit for Navigation by Image-Focused Exploration and fluoroscopy alone. A cardiac phantom was designed and 3D printed to validate the image guidance procedure. In mock procedures, an expert clinician guided and deployed an occluder across the septal defect of the phantom heart. The image guidance method resulted in a dose of 1.26 mSv of radiation dose per procedure, while traditional guidance resulted in a dose of 3.33 mSv. Average overall dose savings for the image-guided method was nearly 2.07 mSv or 62 %. The work showed significant ([Formula: see text]) decrease in radiation dose with use of image guidance methods at the expense of a modest increase in procedure time. This study lays the groundwork for further exploration of image guidance applications in pediatric cardiology.
Mini access guide to simplify calyceal access during percutaneous nephrolithotomy: A novel device.
Chowdhury, Puskar Shyam; Nayak, Prasant; David, Deepak; Mallick, Sujata
2017-01-01
A precise puncture of the renal collecting system is the most essential step for percutaneous nephrolithotomy (PCNL). There are many techniques describing this crucial first step in PCNL including the bull's eye technique, triangulation technique, free-hand technique, and gradual descensus technique. We describe a novel puncture guide to assist accurate percutaneous needle placement during bull's eye technique. The mini access guide (MAG) stabilizes the initial puncture needle by mounting it on an adjustable multidirectional carrier fixed to the patient's skin, which aids in achieving the "bull's eye" puncture. It also avoids a direct fluoroscopic exposure of the urologist's hand during the puncture. Sixty consecutive patients with solitary renal calculus were randomized to traditional hand versus MAG puncture during bull's eye technique of puncture and the fluoroscopy time was assessed. The median fluoroscopy screening time for traditional free-hand bull's eye and MAG-guided bull's eye puncture (fluoroscopic screening time for puncture) was 55 versus 21 s ( P = 0.001) and the median time to puncture was 80 versus 55 s ( P = 0.052), respectively. Novice residents also learned puncture technique faster with MAG on simulator. The MAG is a simple, portable, cheap, and novel assistant to achieve successful PCNL puncture. It would be of great help for novices to establish access during their learning phase of PCNL. It would also be an asset toward significantly decreasing the radiation dose during PCNL access.
X-ray–free Ultrasound-guided Percutaneous Nephrolithotomy: How to Select the Right Patient?
Usawachintachit, Manint; Tzou, David T.; Hu, Weiguo; Li, Jianxing; Chi, Thomas
2017-01-01
OBJECTIVE To identify factors associated with successful ultrasound guidance for each surgical step of ultrasound-guided percutaneous nephrolithotomy (PCNL). PATIENTS AND METHODS Consecutive patients undergoing PCNL between March 2015 and June 2016 were prospectively enrolled. An attempt was made to use ultrasound guidance in renal access, tract dilation, and nephrostomy tube placement for each patient. For steps during which ultrasound guidance was unsuccessful, fluoroscopic screening was applied. Regression analysis identified patient characteristics associated with successful use of ultrasound guidance. RESULTS A total of 96 patients composed this cohort, with a mean body mass index of 28.7 kg/m2. Mean stone size was 33.1 ± 18.9 mm, and no hydronephrosis was found in 63.5% of cases. Fluoroscopic screening was required for renal access in 27 cases (28.1%), tract dilation in 38 (39.6%), and nephrostomy tube placement in 80 (83.3%). Multivariate analysis demonstrated that successful ultrasound guidance was significantly associated with the presence of hydronephrosis for renal access and the absence of staghorn calculi for tract dilation. Ultrasound-guided nephrostomy tube placement appeared linked to surgeon experience. CONCLUSION To achieve completely x-ray–free ultrasound-guided PCNL, the ideal patient should have a hydronephrotic collecting system with no staghorn stone present. For practitioners looking to adopt ultrasound guidance into their PCNL practice, these represent the most appropriate patients to safely initiate a surgical experience. PMID:27720776
Sensor-Based Electromagnetic Navigation (Mediguide®): How Accurate Is It? A Phantom Model Study.
Bourier, Felix; Reents, Tilko; Ammar-Busch, Sonia; Buiatti, Alessandra; Grebmer, Christian; Telishevska, Marta; Brkic, Amir; Semmler, Verena; Lennerz, Carsten; Kaess, Bernhard; Kottmaier, Marc; Kolb, Christof; Deisenhofer, Isabel; Hessling, Gabriele
2015-10-01
Data about localization reproducibility as well as spatial and visual accuracy of the new MediGuide® sensor-based electroanatomic navigation technology are scarce. We therefore sought to quantify these parameters based on phantom experiments. A realistic heart phantom was generated in a 3D-Printer. A CT scan was performed on the phantom. The phantom itself served as ground-truth reference to ensure exact and reproducible catheter placement. A MediGuide® catheter was repeatedly tagged at selected positions to assess accuracy of point localization. The catheter was also used to acquire a MediGuide®-scaled geometry in the EnSite Velocity® electroanatomic mapping system. The acquired geometries (MediGuide®-scaled and EnSite Velocity®-scaled) were compared to a CT segmentation of the phantom to quantify concordance. Distances between landmarks were measured in the EnSite Velocity®- and MediGuide®-scaled geometry and the CT dataset for Bland-Altman comparison. The visualization of virtual MediGuide® catheter tips was compared to their corresponding representation on fluoroscopic cine-loops. Point localization accuracy was 0.5 ± 0.3 mm for MediGuide® and 1.4 ± 0.7 mm for EnSite Velocity®. The 3D accuracy of the geometries was 1.1 ± 1.4 mm (MediGuide®-scaled) and 3.2 ± 1.6 mm (not MediGuide®-scaled). The offset between virtual MediGuide® catheter visualization and catheter representation on corresponding fluoroscopic cine-loops was 0.4 ± 0.1 mm. The MediGuide® system shows a very high level of accuracy regarding localization reproducibility as well as spatial and visual accuracy, which can be ascribed to the magnetic field localization technology. The observed offsets between the geometry visualization and the real phantom are below a clinically relevant threshold. © 2015 Wiley Periodicals, Inc.
Cryo-balloon catheter localization in fluoroscopic images
NASA Astrophysics Data System (ADS)
Kurzendorfer, Tanja; Brost, Alexander; Jakob, Carolin; Mewes, Philip W.; Bourier, Felix; Koch, Martin; Kurzidim, Klaus; Hornegger, Joachim; Strobel, Norbert
2013-03-01
Minimally invasive catheter ablation has become the preferred treatment option for atrial fibrillation. Although the standard ablation procedure involves ablation points set by radio-frequency catheters, cryo-balloon catheters have even been reported to be more advantageous in certain cases. As electro-anatomical mapping systems do not support cryo-balloon ablation procedures, X-ray guidance is needed. However, current methods to provide support for cryo-balloon catheters in fluoroscopically guided ablation procedures rely heavily on manual user interaction. To improve this, we propose a first method for automatic cryo-balloon catheter localization in fluoroscopic images based on a blob detection algorithm. Our method is evaluated on 24 clinical images from 17 patients. The method successfully detected the cryoballoon in 22 out of 24 images, yielding a success rate of 91.6 %. The successful localization achieved an accuracy of 1.00 mm +/- 0.44 mm. Even though our methods currently fails in 8.4 % of the images available, it still offers a significant improvement over manual methods. Furthermore, detecting a landmark point along the cryo-balloon catheter can be a very important step for additional post-processing operations.
A practical guide for performing arthrography under fluoroscopic or ultrasound guidance.
Lungu, Eugen; Moser, Thomas P
2015-12-01
We propose a practical approach for performing arthrography with fluoroscopic or ultrasound guidance. Different approaches to the principal joints of the upper limb (shoulder, elbow, wrist and fingers), lower limb (hip, knee, ankle and foot) as well as the facet joints of the spine are discussed and illustrated with numerous drawings. Whenever possible, we emphasise the concept of targeting articular recesses, which offers many advantages over traditional techniques aiming at the joint space. • Arthrography remains a foremost technique in musculoskeletal radiology • Most joints can be successfully accessed by targeting the articular recess • Targeting the recess offers several advantages over traditional approaches • Ultrasound-guidance is now favoured over fluoroscopy and targeting the recess is equally applicable.
Minimally Invasive Spinal Surgery with Intraoperative Image-Guided Navigation
Kim, Terrence T.; Johnson, J. Patrick; Pashman, Robert; Drazin, Doniel
2016-01-01
We present our perioperative minimally invasive spine surgery technique using intraoperative computed tomography image-guided navigation for the treatment of various lumbar spine pathologies. We present an illustrative case of a patient undergoing minimally invasive percutaneous posterior spinal fusion assisted by the O-arm system with navigation. We discuss the literature and the advantages of the technique over fluoroscopic imaging methods: lower occupational radiation exposure for operative room personnel, reduced need for postoperative imaging, and decreased revision rates. Most importantly, we demonstrate that use of intraoperative cone beam CT image-guided navigation has been reported to increase accuracy. PMID:27213152
How accurately can the peak skin dose in fluoroscopy be determined using indirect dose metrics?
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jones, A. Kyle, E-mail: kyle.jones@mdanderson.org; Ensor, Joe E.; Pasciak, Alexander S.
Purpose: Skin dosimetry is important for fluoroscopically-guided interventions, as peak skin doses (PSD) that result in skin reactions can be reached during these procedures. There is no consensus as to whether or not indirect skin dosimetry is sufficiently accurate for fluoroscopically-guided interventions. However, measuring PSD with film is difficult and the decision to do so must be madea priori. The purpose of this study was to assess the accuracy of different types of indirect dose estimates and to determine if PSD can be calculated within ±50% using indirect dose metrics for embolization procedures. Methods: PSD were measured directly using radiochromicmore » film for 41 consecutive embolization procedures at two sites. Indirect dose metrics from the procedures were collected, including reference air kerma. Four different estimates of PSD were calculated from the indirect dose metrics and compared along with reference air kerma to the measured PSD for each case. The four indirect estimates included a standard calculation method, the use of detailed information from the radiation dose structured report, and two simplified calculation methods based on the standard method. Indirect dosimetry results were compared with direct measurements, including an analysis of uncertainty associated with film dosimetry. Factors affecting the accuracy of the different indirect estimates were examined. Results: When using the standard calculation method, calculated PSD were within ±35% for all 41 procedures studied. Calculated PSD were within ±50% for a simplified method using a single source-to-patient distance for all calculations. Reference air kerma was within ±50% for all but one procedure. Cases for which reference air kerma or calculated PSD exhibited large (±35%) differences from the measured PSD were analyzed, and two main causative factors were identified: unusually small or large source-to-patient distances and large contributions to reference air kerma from cone beam computed tomography or acquisition runs acquired at large primary gantry angles. When calculated uncertainty limits [−12.8%, 10%] were applied to directly measured PSD, most indirect PSD estimates remained within ±50% of the measured PSD. Conclusions: Using indirect dose metrics, PSD can be determined within ±35% for embolization procedures. Reference air kerma can be used without modification to set notification limits and substantial radiation dose levels, provided the displayed reference air kerma is accurate. These results can reasonably be extended to similar procedures, including vascular and interventional oncology. Considering these results, film dosimetry is likely an unnecessary effort for these types of procedures when indirect dose metrics are available.« less
Esophageal stenosis in epidermolysis bullosum: a challenge for the endoscopist.
De Angelis, Paola; Caldaro, Tamara; Torroni, Filippo; Romeo, Erminia; Foschia, Francesca; di Abriola, Giovanni Federici; Rea, Francesca; El Hachem, May; Genovese, Elisabetta; D'Alessandro, Sandra; Dall'Oglio, Luigi
2011-05-01
Esophageal stenosis is a severe complication in dystrophic epidermolysis bullosa (EB). Endoscopic dilations may cause mucosal injury with stricture recurrence. Our aim was to describe our referral EB-center experience on safety and long-term efficacy of fluoroscopically guided balloon dilation without endoscopy. Over 14 years, 34 patients with EB, previously evaluated with barium esophagogram for dysphagia, underwent balloon esophageal dilation. Under fluoroscopy, a guide wire was introduced via a nostril into the stomach. A 12-mm pneumatic balloon, which passed over the wire, was filled using radio-opaque contrast, dilating the stricture. Orotracheal intubation was avoided. Antibiotics, dexamethasone, and proton-pump inhibitors were administered. Study approval was obtained from our ethical board. Ninety-three dilations were performed. Seventeen patients had a single stenosis. The mean age of onset was 18 years (range, 3-47 years). Thirteen patients underwent one dilation. In 6 cases, endoscopy was necessary to visualize the esophageal lumen. Complications included cervical esophageal perforation (2) and transitory dysphagia (10). Thirty patients were feeding within 24 hours. During the follow-up, 2 patients required a gastrostomy, and 2 patients underwent fundoplication for gastroesophageal reflux disease. Fluoroscopically guided balloon dilation in EB is a safe and well-tolerated procedure. An experienced endoscopy team is necessary in certain cases. Copyright © 2011 Elsevier Inc. All rights reserved.
OCCUPATIONAL RADIATION DOSES TO OPERATORS PERFORMING FLUOROSCOPICALLY-GUIDED PROCEDURES
Kim, Kwang Pyo; Miller, Donald L.; de Gonzalez, Amy Berrington; Balter, Stephen; Kleinerman, Ruth A.; Ostroumova, Evgenia; Simon, Steven L.; Linet, Martha S.
2012-01-01
In the past 30 years, the numbers and types of fluoroscopically-guided (FG) procedures have increased dramatically. The objective of the present study is to provide estimated radiation doses to physician specialists, other than cardiologists, who perform FG procedures. We searched Medline to identify English-language journal articles reporting radiation exposures to these physicians. We then identified several primarily therapeutic FG procedures that met specific criteria: well-defined procedures for which there were at least five published reports of estimated radiation doses to the operator, procedures performed frequently in current medical practice, and inclusion of physicians from multiple medical specialties. These procedures were percutaneous nephrolithotomy (PCNL), vertebroplasty, orthopedic extremity nailing for treatment of fractures, biliary tract procedures, transjugular intrahepatic portosystemic shunt creation (TIPS), head/neck endovascular therapeutic procedures, and endoscopic retrograde cholangiopancreatography (ERCP). We abstracted radiation doses and other associated data, and estimated effective dose to operators. Operators received estimated doses per patient procedure equivalent to doses received by interventional cardiologists. The estimated effective dose per case ranged from 1.7 – 56μSv for PCNL, 0.1 – 101 μSv for vertebroplasty, 2.5 – 88μSv for orthopedic extremity nailing, 2.0 – 46μSv for biliary tract procedures, 2.5 – 74μSv for TIPS, 1.8 – 53μSv for head/neck endovascular therapeutic procedures, and 0.2 – 49μSv for ERCP. Overall, mean operator radiation dose per case measured over personal protective devices at different anatomic sites on the head and body ranged from 19 – 800 (median = 113) μSv at eye level, 6 – 1180 (median = 75)μSv at the neck, and 2 – 1600 (median = 302) μSv at the trunk. Operators’ hands often received greater doses than the eyes, neck or trunk. Large variations in operator doses suggest that optimizing procedure protocols and proper use of protective devices and shields might reduce occupational radiation dose substantially. PMID:22647920
Accuracy of ultrasound-guided nerve blocks of the cervical zygapophysial joints.
Siegenthaler, Andreas; Mlekusch, Sabine; Trelle, Sven; Schliessbach, Juerg; Curatolo, Michele; Eichenberger, Urs
2012-08-01
Cervical zygapophysial joint nerve blocks typically are performed with fluoroscopic needle guidance. Descriptions of ultrasound-guided block of these nerves are available, but only one small study compared ultrasound with fluoroscopy, and only for the third occipital nerve. To evaluate the potential usefulness of ultrasound-guidance in clinical practice, studies that determine the accuracy of this technique using a validated control are essential. The aim of this study was to determine the accuracy of ultrasound-guided nerve blocks of the cervical zygapophysial joints using fluoroscopy as control. Sixty volunteers were studied. Ultrasound-imaging was used to place the needle to the bony target of cervical zygapophysial joint nerve blocks. The levels of needle placement were determined randomly (three levels per volunteer). After ultrasound-guided needle placement and application of 0.2 ml contrast dye, fluoroscopic imaging was performed for later evaluation by a blinded pain physician and considered as gold standard. Raw agreement, chance-corrected agreement κ, and chance-independent agreement Φ between the ultrasound-guided placement and the assessment using fluoroscopy were calculated to quantify accuracy. One hundred eighty needles were placed in 60 volunteers. Raw agreement was 87% (95% CI 81-91%), κ was 0.74 (0.64-0.83), and Φ 0.99 (0.99-0.99). Accuracy varied significantly between the different cervical nerves: it was low for the C7 medial branch, whereas all other levels showed very good accuracy. Ultrasound-imaging is an accurate technique for performing cervical zygapophysial joint nerve blocks in volunteers, except for the medial branch blocks of C7.
ICHINOSE, Daisuke; TOCHIGI, Satoru; TANAKA, Toshihide; SUZUKI, Tomoya; TAKEI, Jun; HATANO, Keisuke; KAJIWARA, Ikki; MARUYAMA, Fumiaki; SAKAMOTO, Hiroki; HASEGAWA, Yuzuru; TANI, Satoshi; MURAYAMA, Yuichi
2018-01-01
A 40-year-old man presented with a severe headache, lower back pain, and lower abdominal pain 1 month after a head injury caused by falling. Computed tomography (CT) of the head demonstrated bilateral chronic subdural hematoma (CSDH) with a significant amount in the left frontoparietal region. At the same time, magnetic resonance imaging (MRI) of the lumbar spine also revealed CSDH from L2 to S1 level. A simple drainage for the intracranial CSDH on the left side was performed. Postoperatively, the headache was improved; however, the lower back and abdominal pain persisted. Aspiration of the liquefied spinal subdural hematoma was performed by a lumbar puncture under fluoroscopic guidance. The clinical symptoms were dramatically improved postoperatively. Concomitant intracranial and spinal CSDH is considerably rare so only 23 cases including the present case have been reported in the literature so far. The etiology and therapeutic strategy were discussed with a review of the literature. Therapeutic strategy is not established for these two concomitant lesions. Conservative follow-up was chosen for 14 cases, resulting in a favorable clinical outcome. Although surgical evacuation of lumbosacral CSDH was performed in seven cases, an alteration of cerebrospinal fluid (CSF) pressure following spinal surgery should be reminded because of the intracranial lesion. Since CSDH is well liquefied in both intracranial and spinal lesion, a less invasive approach is recommended not only for an intracranial lesion but also for spinal lesion. Fluoroscopic-guided lumbar puncture for lumbosacral CSDH following burr hole surgery for intracranial CSDH could be a recommended strategy. PMID:29479039
NASA Astrophysics Data System (ADS)
Baptista, M.; Teles, P.; Cardoso, G.; Vaz, P.
2014-11-01
Over the last decade, there was a substantial increase in the number of interventional cardiology procedures worldwide, and the corresponding ionizing radiation doses for both the medical staff and patients became a subject of concern. Interventional procedures in cardiology are normally very complex, resulting in long exposure times. Also, these interventions require the operator to work near the patient and, consequently, close to the primary X-ray beam. Moreover, due to the scattered radiation from the patient and the equipment, the medical staff is also exposed to a non-uniform radiation field that can lead to a significant exposure of sensitive body organs and tissues, such as the eye lens, the thyroid and the extremities. In order to better understand the spatial variation of the dose and dose rate distributions during an interventional cardiology procedure, the dose distribution around a C-arm fluoroscopic system, in operation in a cardiac cath lab at Portuguese Hospital, was estimated using both Monte Carlo (MC) simulations and dosimetric measurements. To model and simulate the cardiac cath lab, including the fluoroscopic equipment used to execute interventional procedures, the state-of-the-art MC radiation transport code MCNPX 2.7.0 was used. Subsequently, Thermo-Luminescent Detector (TLD) measurements were performed, in order to validate and support the simulation results obtained for the cath lab model. The preliminary results presented in this study reveal that the cardiac cath lab model was successfully validated, taking into account the good agreement between MC calculations and TLD measurements. The simulated results for the isodose curves related to the C-arm fluoroscopic system are also consistent with the dosimetric information provided by the equipment manufacturer (Siemens). The adequacy of the implemented computational model used to simulate complex procedures and map dose distributions around the operator and the medical staff is discussed, in view of the optimization principle (and the associated ALARA objective), one of the pillars of the international system of radiological protection.
Kim, Hee Jin; Lee, Tae Won; Ihm, Chun Gyoo; Kim, Myung Jae
2002-01-01
Peritoneal catheter is the lifeline for the continuous ambulatory peritoneal dialysis (CAPD) patients. Over the years, obstruction or displacement of the CAPD catheter has been one of the common complications of CAPD. Fluoroscopy-guided wire manipulation or laparoscopic surgery has been developed to manage outflow obstruction. We analyzed the catheter outcome of fluoroscopy-guided wire manipulation or laparoscopic surgery to determine the ultimate benefit of these procedures. From June 1996 to August 2000, catheter complications were manipulated in 24 patients. Eleven (46%) of these patients were initially managed by guide wire under fluoroscopic control. The remaining 13 (54%) patients were manipulated by laparoscopic surgery. A successful outcome was defined as maintained normal peritoneal catheter function at 30 days after the manipulations. Among the catheters manipulated, 18 (75%) were inserted by nephrologist and 6 (25%) by surgeons at the initiation of CAPD. Tenckhoff double-cuff peritoneal catheters were inserted to all patients. The time elapsed between catheter insertion and manipulation varied from 1 to 60 days with a mean of 11 days. The primary causes of catheter malfunction were kinking in 1 case, omental wrapping with adhesions in 9 cases, and catheter displacements in the remaining 14 cases. Thirty-day catheter function was achieved in 50% (12/24) of initial catheter manipulations, with guide wire under fluoroscopic control (46%, 5/11) and laparoscopic surgery (54%, 7/13). Overall success rate of repeated manipulation was 71% (17 of 24). The successful outcome in repairing of the malfunctioning CAPD catheters could be increased by the combination of fluoroscopy-guided wire manipulation and laparoscopic surgery. Copyright 2002 S. Karger AG, Basel
Minimally invasive fluoroscopic percutaneous peritoneal dialysis catheter salvage.
Narayan, Rajeev; Fried, Terrance; Chica, Gerardo; Schaefer, Mathew; Mullins, Daniel
2014-06-01
Peritoneal dialysis catheter (PDC) dysfunction can often be treated fluoroscopically by manipulation with wire, balloon or stiff stylet, saving surgical intervention for refractory cases. We describe an enhanced percutaneous approach to PDC salvage that can lead to a more definitive intervention and salvage for cases refractory to fluoroscopic manipulation. In five cases of PD catheter malfunction, the deep cuff was dissected free after a 0.035 hydrophilic wire was passed into the peritoneum through the PDC. Only the intraperitoneal portion of the PDC was explanted. The PDC was cleared of obstruction and omentum. The intraperitoneal portion of the PDC was reimplanted over wire via a peel-away sheath and the deep cuff sutured. Omental entrapment was present in three of five patients and fibrin occlusion in four of the five cases. All catheters were repaired successfully by the described technique. Post procedure, 3-5 days of lower volume, recumbent PD exchanges were performed prior to full-dose PD. No perioperative complications or leaks were noted. All PDCs were patent at 6 months. One patient required laparoscopy for recurrent omental wrapping 3 months post intervention. PDC salvage in this manner is a cost-effective alternative to laparoscopic repair of PDCs failing catheter manipulation. The infection barrier afforded by the original superficial cuff and subcutaneous tunnel is maintained. PD can be resumed immediately. Only refractory cases need laparoscopy. This procedure allows for a more definitive correction of catheter migration and obstruction, avoids placement of a new PDC or temporary hemodialysis, is cost-effective and expands percutaneous options for dysfunctional PD catheters.
Giannakopoulos, Stilianos; Bantis, Athanasios; Kalaitzis, Christos; Touloupidis, Stavros
2010-10-01
Occasionally during percutaneous surgery, significant contrast extravasation obscures the field, making fluoroscopic access no longer feasible. Herein, we describe a salvage technique. The cystoscopically placed, open-end ureteral catheter is exchanged with an angled-tip angiographic catheter. With the aid of a guidewire and under fluoroscopic guidance, the tip of the catheter is placed in a posterior calix. The "bull's eye" technique is then applied to direct the needle into the tip of the catheter. This technique was used in four cases over a 7-year period. Successful access was accomplished in all cases through a middle or upper calix. The catheter serves as a target for providing access to the renal collecting system and facilitates final tract dilatation.
Precision of computer-assisted core decompression drilling of the knee.
Beckmann, J; Goetz, J; Bäthis, H; Kalteis, T; Grifka, J; Perlick, L
2006-06-01
Core decompression by exact drilling into the ischemic areas is the treatment of choice in early stages of osteonecrosis of the femoral condyle. Computer-aided surgery might enhance the precision of the drilling and lower the radiation exposure time of both staff and patients. The aim of this study was to evaluate the precision of the fluoroscopically based VectorVision-navigation system in an in vitro model. Thirty sawbones were prepared with a defect filled up with a radiopaque gypsum sphere mimicking the osteonecrosis. 20 sawbones were drilled by guidance of an intraoperative navigation system VectorVision (BrainLAB, Munich, Germany). Ten sawbones were drilled by fluoroscopic control only. A statistically significant difference with a mean distance of 0.58 mm in the navigated group and 0.98 mm in the control group regarding the distance to the desired mid-point of the lesion could be stated. Significant difference was further found in the number of drilling corrections as well as radiation time needed. The fluoroscopic-based VectorVision-navigation system shows a high feasibility and precision of computer-guided drilling with simultaneously reduction of radiation time and therefore could be integrated into clinical routine.
Heavy Metal Pad Shielding during Fluoroscopic Interventions
Dromi, Sergio; Wood, Bradford J.; Oberoi, Jay; Neeman, Ziv
2008-01-01
Significant direct and scatter radiation doses to patient and physician may result from routine interventional radiology practice. A lead-free disposable tungsten antimony shielding pad was tested in phantom patients during simulated diagnostic angiography procedures. Although the exact risk of low doses of ionizing radiation is unknown, dramatic dose reductions can be seen with routine use of this simple, sterile pad made from lightweighttungsten antimony material. PMID:16868175
Miller, Donald L.; Kwon, Deukwoo; Bonavia, Grant H.
2009-01-01
Purpose: To propose initial values for patient reference levels for fluoroscopically guided procedures in the United States. Materials and Methods: This secondary analysis of data from the Radiation Doses in Interventional Radiology Procedures (RAD-IR) study was conducted under a protocol approved by the institutional review board and was HIPAA compliant. Dose distributions (percentiles) were calculated for each type of procedure in the RAD-IR study where there were data from at least 30 cases. Confidence intervals for the dose distributions were determined by using bootstrap resampling. Weight banding and size correction methods for normalizing dose to patient body habitus were tested. Results: The different methods for normalizing patient radiation dose according to patient weight gave results that were not significantly different (P > .05). The 75th percentile patient radiation doses normalized with weight banding were not significantly different from those that were uncorrected for body habitus. Proposed initial reference levels for various interventional procedures are provided for reference air kerma, kerma-area product, fluoroscopy time, and number of images. Conclusion: Sufficient data exist to permit an initial proposal of values for reference levels for interventional radiologic procedures in the United States. For ease of use, reference levels without correction for body habitus are recommended. A national registry of radiation-dose data for interventional radiologic procedures is a necessary next step to refine these reference levels. © RSNA, 2009 Supplemental material: http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.2533090354/-/DC1 PMID:19789226
Imani, Farnad; Hemati, Karim; Rahimzadeh, Poupak; Kazemi, Mohamad Reza; Hejazian, Kokab
2016-01-01
Stellate Ganglion Block (SGB) is an effective technique which may be used to manage upper extremities pain due to Chronic Regional Pain Syndrome (CRPS), in this study we tried to evaluate the effectiveness of this procedure under two different guidance for management of this syndrome. The purpose of this study was to evaluate the effectiveness of ultrsound guide SGB by comparing it with the furoscopy guided SGB in upper extermities CRPS patients in reducing pain & dysfuction of the affected link. Fourteen patients with sympathetic CRPS in upper extremities in a randomized method with block randomization divided in two equal groups (with ultrasound or fluoroscopic guidance). First group was blocked under fluoroscopic guidance and second group blocked under ultrasound guidance. After correct positioning of the needle, a mixture of 5 ml bupivacaine 0.25% and 1 mL of triamcinolone was injected. These data represent no meaningful statistical difference between the two groups in terms of the number of pain attacks before the blocks, a borderline correlation between two groups one week and one month after the block and a significant statistical correlation between two groups three month after the block. These data represent no meaningful statistical difference between the patients of any group in terms of the pain intensity (from one week to six months after block), p-value = 0.61. These data represent a meaningful statistical difference among patients of any group and between the two groups in terms of the pain intensity (before the block until six months after block), p-values were 0.001, 0.031 respectively. According the above mentioned data, in comparison with fluoroscopic guidance, stellate ganglion block under ultrasound guidance is a safe and effective method with lower complication and better improvement in patient's disability indexes.
See, Jason; Amora, Jonah L; Lee, Sheldon; Lim, Paul; Teo, Wee Siong; Tan, Boon Yew; Ho, Kah Leng; Lee, Chee Wan; Ching, Chi-Keong
2016-07-01
The use of non-fluoroscopic systems (NFS) to guide radiofrequency catheter ablation (RFCA) for the treatment of supraventricular tachycardia (SVT) is associated with lower radiation exposure. This study aimed to determine if NFS reduces fluoroscopy time, radiation dose and procedure time. We prospectively enrolled patients undergoing RFCA for SVT. NFS included EnSiteTM NavXTM or CARTO® mapping. We compared procedure and fluoroscopy times, and radiation exposure between NFS and conventional fluoroscopy (CF) cohorts. Procedural success, complications and one-year success rates were reported. A total of 200 patients over 27 months were included and RFCA was guided by NFS for 79 patients; those with atrioventricular nodal reentrant tachycardia (AVNRT), left-sided atrioventricular reentrant tachycardia (AVRT) and right-sided AVRT were included (n = 101, 63 and 36, respectively). Fluoroscopy times were significantly lower with NFS than with CF (10.8 ± 11.1 minutes vs. 32.0 ± 27.5 minutes; p < 0.001). The mean fluoroscopic dose area product was also significantly reduced with NFS (NSF: 5,382 ± 5,768 mGy*cm2 vs. CF: 21,070 ± 23,311 mGy*cm2; p < 0.001); for all SVT subtypes. There was no significant reduction in procedure time, except for left-sided AVRT ablation (NFS: 79.2 minutes vs. CF: 116.4 minutes; p = 0.001). Procedural success rates were comparable (NFS: 97.5% vs. CF: 98.3%) and at one-year follow-up, there was no significant difference in the recurrence rates (NFS: 5.2% vs. CF: 4.2%). No clinically significant complications were observed in both groups. The use of NFS for RFCA for SVT is safe, with significantly reduced radiation dose and fluoroscopy time. Copyright © Singapore Medical Association.
Zhang, Fengxiang; Yang, Bing; Chen, Hongwu; Ju, Weizhu; Kojodjojo, Pipin; Cao, Kejiang; Chen, Minglong
2013-08-01
No randomized controlled study has prospectively compared the performance and clinical outcomes of remote magnetic control (RMC) vs manual catheter control (MCC) during ablation of right ventricular outflow tract (RVOT) ventricular premature complexes (VPC) or ventricular tachycardia (VT). The purpose of this study was to prospectively evaluate the efficacy and safety of using either RMC vs MCC for mapping and ablation of RVOT VPC/VT. Thirty consecutive patients with idiopathic RVOT VPC/VT were referred for catheter ablation and randomized into either the RMC or MCC group. A noncontact mapping system was deployed in the RVOT to identify origins of VPC/VT. Conventional activation and pace-mapping was performed to guide ablation. If ablation performed using 1 mode of catheter control was acutely unsuccessful, the patient crossed over to the other group. The primary endpoints were patients' and physicians' fluoroscopic exposure and times. Mean procedural times were similar between RMC and MCC groups. The fluoroscopic exposure and times for both patients and physicians were much lower in the RMC group than in the MCC group. Ablation was acutely successful in 14 of 15 patients in the MCC group and 10 of 15 in the RMC group. Following crossover, acute success was achieved in all patients. No major complications occurred in either group. During 22 months of follow-up, RVOT VPC recurred in 2 RMC patients. RMC navigation significantly reduces patients' and physicians' fluoroscopic times by 50.5% and 68.6%, respectively, when used in conjunction with a noncontact mapping system to guide ablation of RVOT VPC/VT. Copyright © 2013 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Liu, Wen P.; Armand, Mehran; Otake, Yoshito; Taylor, Russell H.
2011-03-01
Percutaneous femoroplasty [1], or femoral bone augmentation, is a prospective alternative treatment for reducing the risk of fracture in patients with severe osteoporosis. We are developing a surgical robotics system that will assist orthopaedic surgeons in planning and performing a patient-specific, augmentation of the femur with bone cement. This collaborative project, sponsored by the National Institutes of Health (NIH), has been the topic of previous publications [2],[3] from our group. This paper presents modifications to the pose recovery of a fluoroscope tracking (FTRAC) fiducial during our process of 2D/3D registration of X-ray intraoperative images to preoperative CT data. We show improved automata of the initial pose estimation as well as lower projection errors with the advent of a multiimage pose optimization step.
The value of physical examination in the diagnosis of hip osteoarthritis.
Chong, Timothy; Don, Darren W; Kao, Ming-Chih; Wong, Dexter; Mitra, Raj
2013-01-01
To compare the sensitivity of physical examination (internal rotation of the hip) with radiographs (using the Kellgren-Lawrence grading scale) in the diagnosis of clinically significant hip osteoarthritis. Case Series, Retrospective chart review of hip pain patients that underwent fluoroscopically guided hip steroid and anesthetic injections. 10 patients with hip pain patients seen at an academic outpatient center over a 2 year period were analyzed. Fluoroscopically guided hip steroid and anesthetic injection. Pain relief and change in VAS pain score after intra-articular hip steroid and lidocaine injection was the main outcome measure. Based on Fisher's exact test, there was no association between severity of radiographic hip arthritis and pain relief with intra-articular anesthetic/steroid injection (p=0.45). Physical examination (provocative hip internal rotation) however was associated with a significant decrease in VAS pain score after intra-articular lidocaine and corticosteroid hip injection (p=0.022). Simple hip radiographs alone are not sufficient to diagnose clinically significant hip osteoarthritis. Physical examination (hip internal rotation) was found to be more accurate than simple radiographs in the diagnosis of clinically significant hip osteoarthritis. Radiographs seem to best utilized when they are an extension of the physical examination and patient history.
ANGIOGRAPHIC ANATOMY OF THE MAJOR ABDOMINAL ARTERIAL BLOOD SUPPLY IN THE DOG.
Culp, William T N; Mayhew, Philipp D; Pascoe, Peter J; Zwingenberger, Allison
2015-01-01
Vascular-based interventional radiology (IR) procedures are being more regularly performed in veterinary patients for both diagnostic and therapeutic purposes. A complete description of the fluoroscopic arterial anatomy of the canine abdominal cavity has not been published. This information is essential for performance of IR procedures to allow for improved preparation before and during a particular procedure. The primary purpose of this study was to provide a fluoroscopic description of the vascular branching from the abdominal aorta in a ventro-dorsal projection with a secondary goal of producing pictorial reference images of the major abdominal arterial blood vessels. Five healthy female hound type dogs were enrolled and underwent fluoroscopic arteriography. During fluoroscopy, both nonselective and selective arteriography were performed. The nonselective arteriograms were obtained in the aorta at four locations: cranial to the celiac artery, cranial to the renal arteries, cranial to the caudal mesenteric artery, and cranial to the branching of the external iliac arteries. Selective arteriography was conducted by performing injections into the following arteries: celiac, splenic, common hepatic, cranial mesenteric, left and right renal, and caudal mesenteric. Fluoroscopic arteriography allowed for excellent characterization of the aortic ostia and the location of the lower order vascular branches. Future evaluation of vascular-based treatment options will likely increase as the understanding of the normal and pathologic anatomy improves. © 2015 American College of Veterinary Radiology.
X-ray beam equalization for digital fluoroscopy
NASA Astrophysics Data System (ADS)
Molloi, Sabee Y.; Tang, Jerry; Marcin, Martin R.; Zhou, Yifang; Anvar, Behzad
1996-04-01
The concept of radiographic equalization has previously been investigated. However, a suitable technique for digital fluoroscopic applications has not been developed. The previously reported scanning equalization techniques cannot be applied to fluoroscopic applications due to their exposure time limitations. On the other hand, area beam equalization techniques are more suited for digital fluoroscopic applications. The purpose of this study is to develop an x- ray beam equalization technique for digital fluoroscopic applications that will produce an equalized radiograph with minimal image artifacts and tube loading. Preliminary unequalized images of a humanoid chest phantom were acquired using a digital fluoroscopic system. Using this preliminary image as a guide, an 8 by 8 array of square pistons were used to generate masks in a mold with CeO2. The CeO2 attenuator thicknesses were calculated using the gray level information from the unequalized image. The generated mask was positioned close to the focal spot (magnification of 8.0) in order to minimize edge artifacts from the mask. The masks were generated manually in order to investigate the piston and matrix size requirements. The development of an automated version of mask generation and positioning is in progress. The results of manual mask generation and positioning show that it is possible to generate equalized radiographs with minimal perceptible artifacts. The equalization of x-ray transmission across the field exiting from the object significantly improved the image quality by preserving local contrast throughout the image. Furthermore, the reduction in dynamic range significantly reduced the effect of x-ray scatter and veiling glare from high transmission to low transmission areas. Also, the x-ray tube loading due to the mask assembly itself was negligible. In conclusion it is possible to produce area beam compensation that will be compatible with digital fluoroscopy with minimal compensation artifacts. The compensation process produces an image with equalized signal to noise ratio in all parts of the image.
Wannagat, Severin; Loehr, Lena; Lask, Sebastian; Völk, Katharina; Karaköse, Tamer; Özcelik, Cemil; Mügge, Andreas; Wutzler, Alexander
2018-04-01
Catheter ablation is performed under fluoroscopic guidance. Reduction of radiation dose for patients and staff is emphasized by current recommendations. Previous studies have shown that lower operator experience leads to increased radiation dose. On the other hand, less experienced operators may depend even more on fluoroscopic guidance. Our study aimed to evaluate feasibility and efficacy of a non-fluoroscopic approach in different training levels. From January 2017, a near-zero fluoroscopy approach was established in two centers. Four operators (beginner, 1st year fellow, 2nd year fellow, expert) were instructed to perform the complete procedure with the use of a 3-D mapping system without fluoroscopy. A historical cohort that underwent procedures with fluoroscopy use served as control group. Dose area product (DPA), procedure duration, acute procedural success, and complications were compared between the groups and for each operator. Procedures were performed in 157 patients. The first 100 patients underwent procedures with fluoroscopic guidance, the following 57 procedures were performed with the near-zero fluoroscopy approach. The results show a significant reduction in DPA for all operators immediately after implementation of the near-zero fluoroscopy protocol (control 637 ± 611 μGy/m 2 ; beginner 44.1 ± 79.5 μGy/m 2 , p = 0.002; 1st year fellow 24.3 ± 46.4.5 μGy/m 2 , p = 0.001; 2nd year fellow 130.3 ± 233.3 μGy/m 2 , p = 0.003; expert 9.3 ± 37.4 μGy/m 2 , P < 0.001). Procedure duration, acute success, and complications were not significantly different between the groups. Our results show a 90% reduction of DPA shortly after implementation of a near-zero fluoroscopy approach in interventional electrophysiology even in operators in training.
Fluoroscopic Sacroiliac Joint Injection: Is Oblique Angulation Really Necessary?
Khuba, Sandeep; Agarwal, Anil; Gautam, Sujeet; Kumar, Sanjay
2016-01-01
The conventional technique for sacroiliac (SI) joint injection involves aligning the anterior and posterior aspects of the SI joint under fluoroscopic guidance and then entering the SI joint in the most caudal aspect. We wish to highlight that there is no added advantage to aligning both the anterior and posterior joint lines of the SI joint as it is time consuming, associated with additional radiation exposure, and may make the entry into the posterior SI joint technically more difficult. Observational study. Pain Clinic, Department of Anesthesiology. With the patient lying prone on fluoroscopy table, SI joint injection is performed with a 22 G, 10 cm spinal needle in a true anteroposterior (AP) view, where anterior and posterior SI joint spaces are seen as separate entities, where the medial joint space represents the posterior SI joint and the lateral joint space represents the anterior SI joint. The distal 1 cm of the medial joint space is entered under AP view. If the SI joint is seen as a straight line rather than 2 joint spaces in the AP view then the image intensifier of the fluoroscope was tilted cranially to elongate the image of the lower part of the posterior SI joint, thus facilitating entry into this part of the joint which was confirmed by administering 0.3 to 0.5 mL of radiopaque contrast medium. Sixty SI joints of 58 patients were injected under an AP fluoroscopic view. Forty-two (70%) SI joints were seen as 2 separate medial and lateral joint spaces and were entered in distal 1 cm of the medial joint space. In 18 (30%) joints seen as a straight line rather than 2 separate spaces, the image intensifier of the fluoroscope was tilted cranially to elongate the image of the lower part of the posterior SI joint and then the SI joint was entered in its distal 1 cm. Confirmation of entry into the SI joint was confirmed by with 0.3 to 0.5 mL of radiopaque contrast medium. In 4 cases the joints did not show the correct radiopaque contrast spread (3/42 and 1/18) although the needle seemed to be in the joint space. Small sample size. Aligning the anterior and posterior aspects of SI joint for fluoroscopic guided SI joint injection is not necessary for the success of the block.Key words: Sacroiliac joint, injection, anteroposterior view, oblique angulation, fluoroscopic technique.
Technical advances of interventional fluoroscopy and flat panel image receptor.
Lin, Pei-Jan Paul
2008-11-01
In the past decade, various radiation reducing devices and control circuits have been implemented on fluoroscopic imaging equipment. Because of the potential for lengthy fluoroscopic procedures in interventional cardiovascular angiography, these devices and control circuits have been developed for the cardiac catheterization laboratories and interventional angiography suites. Additionally, fluoroscopic systems equipped with image intensifiers have benefited from technological advances in x-ray tube, x-ray generator, and spectral shaping filter technologies. The high heat capacity x-ray tube, the medium frequency inverter generator with high performance switching capability, and the patient dose reduction spectral shaping filter had already been implemented on the image intensified fluoroscopy systems. These three underlying technologies together with the automatic dose rate and image quality (ADRIQ) control logic allow patients undergoing cardiovascular angiography procedures to benefit from "lower patient dose" with "high image quality." While photoconductor (or phosphor plate) x-ray detectors and signal capture thin film transistor (TFT) and charge coupled device (CCD) arrays are analog in nature, the advent of the flat panel image receptor allowed for fluoroscopy procedures to become more streamlined. With the analog-to-digital converter built into the data lines, the flat panel image receptor appears to become a digital device. While the transition from image intensified fluoroscopy systems to flat panel image receptor fluoroscopy systems is part of the on-going "digitization of imaging," the value of a flat panel image receptor may have to be evaluated with respect to patient dose, image quality, and clinical application capabilities. The advantage of flat panel image receptors has yet to be fully explored. For instance, the flat panel image receptor has its disadvantages as compared to the image intensifiers; the cost of the equipment is probably the most obvious. On the other hand, due to its wide dynamic range and linearity, lowering of patient dose beyond current practice could be achieved through the calibration process of the flat panel input dose rate being set to, for example, one half or less of current values. In this article various radiation saving devices and control circuits are briefly described. This includes various types of fluoroscopic systems designed to strive for reduction of patient exposure with the application of spectral shaping filters. The main thrust is to understand the ADRIQ control logic, through equipment testing, as it relates to clinical applications, and to show how this ADRIQ control logic "ties" those three technological advancements together to provide low radiation dose to the patient with high quality fluoroscopic images. Finally, rotational angiography with computed tomography (CT) and three dimensional (3-D) images utilizing flat panel technology will be reviewed as they pertain to diagnostic imaging in cardiovascular disease.
Endoscope-guided pneumatic dilation for treatment of esophageal achalasia
Chuah, Seng-Kee; Wu, Keng-Liang; Hu, Tsung-Hui; Tai, Wei-Chen; Changchien, Chi-Sin
2010-01-01
Pneumatic dilation (PD) is considered to be the first line nonsurgical therapy for achalasia. The principle of the procedure is to weaken the lower esophageal sphincter by tearing its muscle fibers by generating radial force. The endoscope-guided procedure is done without fluoroscopic control. Clinicians usually use a low-compliance balloon such as Rigiflex dilator to perform endoscope-guided PD for the treatment of esophageal achalasia. It has the advantage of determining mucosal injury during the dilation process, so that a repeat endoscopy is not needed to assess the mucosal tearing. Previous studies have shown that endoscope-guided PD is an efficient and safe nonsurgical therapy with results that compare well with other treatment modalities. Although the results may be promising, long-term follow-up is required in the near future. PMID:20101764
Percutaneous biliary drainage for high obstruction.
Barth, K H
1990-11-01
PBD is the preferred route of palliative drainage for patients with high biliary obstruction. The frequency of bifurcational obstruction in this setting requires familiarity with drainages from both the right and the left transhepatic approach. The preferred right transhepatic approach is fluoroscopically guided; on the left, ultrasonography is the guidance of choice. Large caliber drainage catheters are required, and dilatation of the necessary transhepatic tracts is extremely painful unless adequate inhalation anesthesia or, preferably, epidural anesthesia, is provided. Long-term biliary drainage requires a choice between internal-external external drainage catheters and endoprostheses that is made by considering the patient's life expectancy and his or her adjustment to a stent extending to the outside. The feasibility of corrective procedures if an internal-external drainage catheter or an endoprosthesis becomes blocked needs to be considered before definitive placement. The interventional radiologist becomes intimately involved in the follow-up care of patients and frequently has to direct appropriate patient evaluation. Familiarity with antibiotic regimens is important.
Scillia, Anthony; Issa, Kimona; McInerney, Vincent K; Milman, Edward; Baltazar, Romulo; Dasti, Umer; Festa, Anthony
2015-08-01
The purpose of this study was to evaluate the accuracy of in vivo acromioclavicular (AC) joint injections without fluoroscopic guidance and assess whether patient demographics affected the accuracy of injections. A consecutive cohort of patients who presented with painful acromioclavicular joints was prospectively evaluated. All patients had clinical and radiographic evidence of AC arthritis, had failed conservative measures, and thus had received intraarticular corticosteroid injections. All injections were performed by experienced fellowship-trained musculoskeletal radiologists and by blinded digital palpation technique. Accuracy of injections was assessed with biplanar fluoroscopic views. Forty-one AC injections in 22 males and 16 females with a mean age of 51 years (range 18 to 78) were identified. Twenty-three injections were in the right shoulder and 18 in the left. Only 15 injections were confirmed to be in the intraarticular AC joint, yielding an accuracy of 36.5%. There were no significant differences in the mean age (54 vs. 52 years; p = 0.58), male-to-female ratio (p = 0.73), and side of the injection between the accurate and inaccurate injections, respectively. Based on the findings of the present study, the authors encourage the use of image guidance for corticosteroid treatment of the AC joint. Level IV Therapeutic Case Series.
Casella, Michela; Dello Russo, Antonio; Pelargonio, Gemma; Bongiorni, Maria Grazia; Del Greco, Maurizio; Piacenti, Marcello; Andreassi, Maria Grazia; Santangeli, Pasquale; Bartoletti, Stefano; Moltrasio, Massimo; Fassini, Gaetano; Marini, Massimiliano; Di Cori, Andrea; Di Biase, Luigi; Fiorentini, Cesare; Zecchi, Paolo; Natale, Andrea; Picano, Eugenio; Tondo, Claudio
2012-10-01
Radiofrequency catheter ablation is the mainstay of therapy for supraventricular tachyarrhythmias. Conventional radiofrequency catheter ablation requires the use of fluoroscopy, thus exposing patients to ionising radiation. The feasibility and safety of non-fluoroscopic radiofrequency catheter ablation has been recently reported in a wide range of supraventricular tachyarrhythmias using the EnSite NavX™ mapping system. The NO-PARTY is a multi-centre, randomised controlled trial designed to test the hypothesis that catheter ablation of supraventricular tachyarrhythmias guided by the EnSite NavX™ mapping system results in a clinically significant reduction in exposure to ionising radiation compared with conventional catheter ablation. The study will randomise 210 patients undergoing catheter ablation of supraventricular tachyarrhythmias to either a conventional ablation technique or one guided by the EnSite NavX™ mapping system. The primary end-point is the reduction of the radiation dose to the patient. Secondary end-points include procedural success, reduction of the radiation dose to the operator, and a cost-effectiveness analysis. In a subgroup of patients, we will also evaluate the radiobiological effectiveness of dose reduction by assessing acute chromosomal DNA damage in peripheral blood lymphocytes. NO-PARTY will determine whether radiofrequency catheter ablation of supraventricular tachyarrhythmias guided by the EnSite NavX™ mapping system is a suitable and cost-effective approach to achieve a clinically significant reduction in ionising radiation exposure for both patient and operator.
Rouabah, K; Varoquaux, A; Caporossi, J M; Louis, G; Jacquier, A; Bartoli, J M; Moulin, G; Vidal, V
2016-11-01
The purpose of this study was to assess the feasibility and utility of image fusion (Easy-TIPS) obtained from pre-procedure CT angiography and per-procedure real-time fluoroscopy for portal vein puncture during transjugular intrahepatic portosystemic shunt (TIPS) placement. Eighteen patients (15 men, 3 women) with a mean age of 63 years (range: 48-81 years; median age, 65 years) were included in the study. All patients underwent TIPS placement by two groups of radiologists (one group with radiologists of an experience<3 years and one with an experience≥3 years) using fusion imaging obtained from three-dimensional computed tomography angiography of the portal vein and real-time fluoroscopic images of the portal vein. Image fusion was used to guide the portal vein puncture during TIPS placement. At the end of the procedure, the interventional radiologists evaluated the utility of fusion imaging for portal vein puncture during TIPS placement. Mismatch between three-dimensional computed tomography angiography and real-time fluoroscopic images of the portal vein on image fusion was quantitatively analyzed. Posttreatment CT time, number of the puncture attempts, total radiation exposure and radiation from the retrograde portography were also recorded. Image fusion was considered useful for portal vein puncture in 13/18 TIPS procedures (72%). The mean posttreatment time to obtain fusion images was 16.4minutes. 3D volume rendered CT angiography images was strictly superimposed on direct portography in 10/18 procedures (56%). The mismatch mean value was 0.69cm in height and 0.28cm laterally. A mean number of 4.6 portal vein puncture attempts was made. Eight patients required less than three attempts. The mean radiation dose from retrograde portography was 421.2dGy.cm 2 , corresponding to a mean additional exposure of 19%. Fusion imaging resulting from image fusion from pre-procedural CT angiography is feasible, safe and makes portal puncture easier during TIPS placement. Copyright © 2016 Editions françaises de radiologie. Published by Elsevier Masson SAS. All rights reserved.
Kirkwood, Melissa L; Arbique, Gary M; Guild, Jeffrey B; Zeng, Katie; Xi, Yin; Rectenwald, John; Anderson, Jon A; Timaran, Carlos
2018-03-12
Radiation to the interventionalist's brain during fluoroscopically guided interventions (FGIs) may increase the incidence of cerebral neoplasms. Lead equivalent surgical caps claim to reduce radiation brain doses by 50% to 95%. We sought to determine the efficacy of the RADPAD (Worldwide Innovations & Technologies, Lenexa, Kan) No Brainer surgical cap (0.06 mm lead equivalent at 90 kVp) in reducing radiation dose to the surgeon's and trainee's head during FGIs and to a phantom to determine relative brain dose reductions. Optically stimulated, luminescent nanoDot detectors (Landauer, Glenwood, Ill) inside and outside of the cap at the left temporal position were used to measure cap attenuation during FGIs. To check relative brain doses, nanoDot detectors were placed in 15 positions within an anthropomorphic head phantom (ATOM model 701; CIRS, Norfolk, Va). The phantom was positioned to represent a primary operator performing femoral access. Fluorography was performed on a plastic scatter phantom at 80 kVp for an exposure of 5 Gy reference air kerma with or without the hat. For each brain location, the percentage dose reduction with the hat was calculated. Means and standard errors were calculated using a pooled linear mixed model with repeated measurements. Anatomically similar locations were combined into five groups: upper brain, upper skull, midbrain, eyes, and left temporal position. This was a prospective, single-center study that included 29 endovascular aortic aneurysm procedures. The average procedure reference air kerma was 2.6 Gy. The hat attenuation at the temporal position for the attending physician and fellow was 60% ± 20% and 33% ± 36%, respectively. The equivalent phantom measurements demonstrated an attenuation of 71% ± 2.0% (P < .0001). In the interior phantom locations, attenuation was statistically significant for the skull (6% ± 1.4%) and upper brain (7.2% ± 1.0%; P < .0001) but not for the middle brain (1.4% ± 1.0%; P = .15) or the eyes (-1.5% ± 1.4%; P = .28). The No Brainer surgical cap attenuates direct X rays at the superficial temporal location; however, the majority of radiation to an interventionalist's brain originates from scatter radiation from angles not shadowed by the cap as demonstrated by the trivial percentage brain dose reductions measured in the phantom. Radiation protective caps have minimal clinical relevance. Copyright © 2018 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.
A Hybrid Reality Radiation-free Simulator for Teaching Wire Navigation Skills
Kho, Jenniefer Y.; Johns, Brian D.; Thomas, Geb. W.; Karam, Matthew D.; Marsh, J. Lawrence; Anderson, Donald D.
2016-01-01
Objectives Surgical simulation is an increasingly important method to facilitate the acquiring of surgical skills. Simulation can be helpful in developing hip fracture fixation skills because it is a common procedure for which performance can be objectively assessed (i.e., the tip-apex distance). The procedure requires fluoroscopic guidance to drill a wire along an osseous trajectory to a precise position within bone. The objective of this study was to assess the construct validity for a novel radiation-free simulator designed to teach wire navigation skills in hip fracture fixation. Methods Novices (N=30) with limited to no surgical experience in hip fracture fixation and experienced surgeons (N=10) participated. Participants drilled a guide wire in the center-center position of a synthetic femoral head in a hip fracture simulator, using electromagnetic sensors to track the guide wire position. Sensor data were gathered to generate fluoroscopic-like images of the hip and guide wire. Simulator performance of novice and experienced participants was compared to measure construct validity. Results The simulator was able to discriminate the accuracy in guide wire position between novices and experienced surgeons. Experienced surgeons achieved a more accurate tip-apex distance than novices (13 vs 23 mm, respectively, p=0.009). The magnitude of improvement on successive simulator attempts was dependent on level of expertise; tip-apex distance improved significantly in the novice group, while it was unchanged in the experienced group. Conclusions This hybrid reality, radiation-free hip fracture simulator, which combines real-world objects with computer-generated imagery demonstrates construct validity by distinguishing the performance of novices and experienced surgeons. There is a differential effect depending on level of experience, and it could be used as an effective training tool in novice surgeons. PMID:26165262
Theoretical performance analysis for CMOS based high resolution detectors.
Jain, Amit; Bednarek, Daniel R; Rudin, Stephen
2013-03-06
High resolution imaging capabilities are essential for accurately guiding successful endovascular interventional procedures. Present x-ray imaging detectors are not always adequate due to their inherent limitations. The newly-developed high-resolution micro-angiographic fluoroscope (MAF-CCD) detector has demonstrated excellent clinical image quality; however, further improvement in performance and physical design may be possible using CMOS sensors. We have thus calculated the theoretical performance of two proposed CMOS detectors which may be used as a successor to the MAF. The proposed detectors have a 300 μm thick HL-type CsI phosphor, a 50 μm-pixel CMOS sensor with and without a variable gain light image intensifier (LII), and are designated MAF-CMOS-LII and MAF-CMOS, respectively. For the performance evaluation, linear cascade modeling was used. The detector imaging chains were divided into individual stages characterized by one of the basic processes (quantum gain, binomial selection, stochastic and deterministic blurring, additive noise). Ranges of readout noise and exposure were used to calculate the detectors' MTF and DQE. The MAF-CMOS showed slightly better MTF than the MAF-CMOS-LII, but the MAF-CMOS-LII showed far better DQE, especially for lower exposures. The proposed detectors can have improved MTF and DQE compared with the present high resolution MAF detector. The performance of the MAF-CMOS is excellent for the angiography exposure range; however it is limited at fluoroscopic levels due to additive instrumentation noise. The MAF-CMOS-LII, having the advantage of the variable LII gain, can overcome the noise limitation and hence may perform exceptionally for the full range of required exposures; however, it is more complex and hence more expensive.
Keleshis, C; Ionita, CN; Yadava, G; Patel, V; Bednarek, DR; Hoffmann, KR; Verevkin, A; Rudin, S
2008-01-01
A graphical user interface based on LabVIEW software was developed to enable clinical evaluation of a new High-Sensitivity Micro-Angio-Fluoroscopic (HSMAF) system for real-time acquisition, display and rapid frame transfer of high-resolution region-of-interest images. The HSMAF detector consists of a CsI(Tl) phosphor, a light image intensifier (LII), and a fiber-optic taper coupled to a progressive scan, frame-transfer, charged-coupled device (CCD) camera which provides real-time 12 bit, 1k × 1k images capable of greater than 10 lp/mm resolution. Images can be captured in continuous or triggered mode, and the camera can be programmed by a computer using Camera Link serial communication. A graphical user interface was developed to control the camera modes such as gain and pixel binning as well as to acquire, store, display, and process the images. The program, written in LabVIEW, has the following capabilities: camera initialization, synchronized image acquisition with the x-ray pulses, roadmap and digital subtraction angiography acquisition (DSA), flat field correction, brightness and contrast control, last frame hold in fluoroscopy, looped playback of the acquired images in angiography, recursive temporal filtering and LII gain control. Frame rates can be up to 30 fps in full-resolution mode. The user friendly implementation of the interface along with the high framerate acquisition and display for this unique high-resolution detector should provide angiographers and interventionalists with a new capability for visualizing details of small vessels and endovascular devices such as stents and hence enable more accurate diagnoses and image guided interventions. (Support: NIH Grants R01NS43924, R01EB002873) PMID:18836570
Keleshis, C; Ionita, Cn; Yadava, G; Patel, V; Bednarek, Dr; Hoffmann, Kr; Verevkin, A; Rudin, S
2008-01-01
A graphical user interface based on LabVIEW software was developed to enable clinical evaluation of a new High-Sensitivity Micro-Angio-Fluoroscopic (HSMAF) system for real-time acquisition, display and rapid frame transfer of high-resolution region-of-interest images. The HSMAF detector consists of a CsI(Tl) phosphor, a light image intensifier (LII), and a fiber-optic taper coupled to a progressive scan, frame-transfer, charged-coupled device (CCD) camera which provides real-time 12 bit, 1k × 1k images capable of greater than 10 lp/mm resolution. Images can be captured in continuous or triggered mode, and the camera can be programmed by a computer using Camera Link serial communication. A graphical user interface was developed to control the camera modes such as gain and pixel binning as well as to acquire, store, display, and process the images. The program, written in LabVIEW, has the following capabilities: camera initialization, synchronized image acquisition with the x-ray pulses, roadmap and digital subtraction angiography acquisition (DSA), flat field correction, brightness and contrast control, last frame hold in fluoroscopy, looped playback of the acquired images in angiography, recursive temporal filtering and LII gain control. Frame rates can be up to 30 fps in full-resolution mode. The user friendly implementation of the interface along with the high framerate acquisition and display for this unique high-resolution detector should provide angiographers and interventionalists with a new capability for visualizing details of small vessels and endovascular devices such as stents and hence enable more accurate diagnoses and image guided interventions. (Support: NIH Grants R01NS43924, R01EB002873).
Simultaneous fluoroscopic and nuclear imaging: impact of collimator choice on nuclear image quality.
van der Velden, Sandra; Beijst, Casper; Viergever, Max A; de Jong, Hugo W A M
2017-01-01
X-ray-guided oncological interventions could benefit from the availability of simultaneously acquired nuclear images during the procedure. To this end, a real-time, hybrid fluoroscopic and nuclear imaging device, consisting of an X-ray c-arm combined with gamma imaging capability, is currently being developed (Beijst C, Elschot M, Viergever MA, de Jong HW. Radiol. 2015;278:232-238). The setup comprises four gamma cameras placed adjacent to the X-ray tube. The four camera views are used to reconstruct an intermediate three-dimensional image, which is subsequently converted to a virtual nuclear projection image that overlaps with the X-ray image. The purpose of the present simulation study is to evaluate the impact of gamma camera collimator choice (parallel hole versus pinhole) on the quality of the virtual nuclear image. Simulation studies were performed with a digital image quality phantom including realistic noise and resolution effects, with a dynamic frame acquisition time of 1 s and a total activity of 150 MBq. Projections were simulated for 3, 5, and 7 mm pinholes and for three parallel hole collimators (low-energy all-purpose (LEAP), low-energy high-resolution (LEHR) and low-energy ultra-high-resolution (LEUHR)). Intermediate reconstruction was performed with maximum likelihood expectation-maximization (MLEM) with point spread function (PSF) modeling. In the virtual projection derived therefrom, contrast, noise level, and detectability were determined and compared with the ideal projection, that is, as if a gamma camera were located at the position of the X-ray detector. Furthermore, image deformations and spatial resolution were quantified. Additionally, simultaneous fluoroscopic and nuclear images of a sphere phantom were acquired with a physical prototype system and compared with the simulations. For small hot spots, contrast is comparable for all simulated collimators. Noise levels are, however, 3 to 8 times higher in pinhole geometries than in parallel hole geometries. This results in higher contrast-to-noise ratios for parallel hole geometries. Smaller spheres can thus be detected with parallel hole collimators than with pinhole collimators (17 mm vs 28 mm). Pinhole geometries show larger image deformations than parallel hole geometries. Spatial resolution varied between 1.25 cm for the 3 mm pinhole and 4 cm for the LEAP collimator. The simulation method was successfully validated by the experiments with the physical prototype. A real-time hybrid fluoroscopic and nuclear imaging device is currently being developed. Image quality of nuclear images obtained with different collimators was compared in terms of contrast, noise, and detectability. Parallel hole collimators showed lower noise and better detectability than pinhole collimators. © 2016 American Association of Physicists in Medicine.
Entrapment of Guide Wire in an Inferior Vena Cava Filter: A Technique for Removal
DOE Office of Scientific and Technical Information (OSTI.GOV)
Abdel-Aal, Ahmed Kamel, E-mail: akamel@uabmc.edu; Saddekni, Souheil; Hamed, Maysoon Farouk
Entrapment of a central venous catheter (CVC) guide wire in an inferior vena cava (IVC) filter is a rare, but reported complication during CVC placement. With the increasing use of vena cava filters (VCFs), this number will most likely continue to grow. The consequences of this complication can be serious, as continued traction upon the guide wire may result in filter dislodgement and migration, filter fracture, or injury to the IVC. We describe a case in which a J-tipped guide wire introduced through a left subclavian access without fluoroscopic guidance during CVC placement was entrapped at the apex of anmore » IVC filter. We describe a technique that we used successfully in removing the entrapped wire through the left subclavian access site. We also present simple useful recommendations to prevent this complication.« less
Fast skin dose estimation system for interventional radiology
Takata, Takeshi; Kotoku, Jun’ichi; Maejima, Hideyuki; Kumagai, Shinobu; Arai, Norikazu; Kobayashi, Takenori; Shiraishi, Kenshiro; Yamamoto, Masayoshi; Kondo, Hiroshi; Furui, Shigeru
2018-01-01
Abstract To minimise the radiation dermatitis related to interventional radiology (IR), rapid and accurate dose estimation has been sought for all procedures. We propose a technique for estimating the patient skin dose rapidly and accurately using Monte Carlo (MC) simulation with a graphical processing unit (GPU, GTX 1080; Nvidia Corp.). The skin dose distribution is simulated based on an individual patient’s computed tomography (CT) dataset for fluoroscopic conditions after the CT dataset has been segmented into air, water and bone based on pixel values. The skin is assumed to be one layer at the outer surface of the body. Fluoroscopic conditions are obtained from a log file of a fluoroscopic examination. Estimating the absorbed skin dose distribution requires calibration of the dose simulated by our system. For this purpose, a linear function was used to approximate the relation between the simulated dose and the measured dose using radiophotoluminescence (RPL) glass dosimeters in a water-equivalent phantom. Differences of maximum skin dose between our system and the Particle and Heavy Ion Transport code System (PHITS) were as high as 6.1%. The relative statistical error (2 σ) for the simulated dose obtained using our system was ≤3.5%. Using a GPU, the simulation on the chest CT dataset aiming at the heart was within 3.49 s on average: the GPU is 122 times faster than a CPU (Core i7–7700K; Intel Corp.). Our system (using the GPU, the log file, and the CT dataset) estimated the skin dose more rapidly and more accurately than conventional methods. PMID:29136194
Fast skin dose estimation system for interventional radiology.
Takata, Takeshi; Kotoku, Jun'ichi; Maejima, Hideyuki; Kumagai, Shinobu; Arai, Norikazu; Kobayashi, Takenori; Shiraishi, Kenshiro; Yamamoto, Masayoshi; Kondo, Hiroshi; Furui, Shigeru
2018-03-01
To minimise the radiation dermatitis related to interventional radiology (IR), rapid and accurate dose estimation has been sought for all procedures. We propose a technique for estimating the patient skin dose rapidly and accurately using Monte Carlo (MC) simulation with a graphical processing unit (GPU, GTX 1080; Nvidia Corp.). The skin dose distribution is simulated based on an individual patient's computed tomography (CT) dataset for fluoroscopic conditions after the CT dataset has been segmented into air, water and bone based on pixel values. The skin is assumed to be one layer at the outer surface of the body. Fluoroscopic conditions are obtained from a log file of a fluoroscopic examination. Estimating the absorbed skin dose distribution requires calibration of the dose simulated by our system. For this purpose, a linear function was used to approximate the relation between the simulated dose and the measured dose using radiophotoluminescence (RPL) glass dosimeters in a water-equivalent phantom. Differences of maximum skin dose between our system and the Particle and Heavy Ion Transport code System (PHITS) were as high as 6.1%. The relative statistical error (2 σ) for the simulated dose obtained using our system was ≤3.5%. Using a GPU, the simulation on the chest CT dataset aiming at the heart was within 3.49 s on average: the GPU is 122 times faster than a CPU (Core i7-7700K; Intel Corp.). Our system (using the GPU, the log file, and the CT dataset) estimated the skin dose more rapidly and more accurately than conventional methods.
NASA Astrophysics Data System (ADS)
Vijayan, Sarath; Shankar, Alok; Rudin, Stephen; Bednarek, Daniel R.
2016-03-01
The skin dose tracking system (DTS) that we developed provides a color-coded mapping of the cumulative skin dose distribution on a 3D graphic of the patient during fluoroscopic procedures in real time. The DTS has now been modified to also calculate the kerma area product (KAP) and cumulative air kerma (CAK) for fluoroscopic interventions using data obtained in real-time from the digital bus on a Toshiba Infinix system. KAP is the integral of air kerma over the beam area and is typically measured with a large-area transmission ionization chamber incorporated into the collimator assembly. In this software, KAP is automatically determined for each x-ray pulse as the product of the air kerma/ mAs from a calibration file for the given kVp and beam filtration times the mAs per pulse times the length and width of the beam times a field nonuniformity correction factor. Field nonuniformity is primarily the result of the heel effect and the correction factor was determined from the beam profile measured using radio-chromic film. Dividing the KAP by the beam area at the interventional reference point provides the area averaged CAK. The KAP and CAK per x-ray pulse are summed after each pulse to obtain the total procedure values in real-time. The calculated KAP and CAK were compared to the values displayed by the fluoroscopy machine with excellent agreement. The DTS now is able to automatically calculate both KAP and CAK without the need for measurement by an add-on transmission ionization chamber.
Ansari, Md Abu Masud; Kumar, Naveen; Kumar, Shailesh; Kumari, Sarita
2016-10-01
Central venous Catheterization (CVC) is a commonly performed procedure for venous access. It is associated with several complications. We report a rare case of extra luminal entrapment of guide wire during CVC placement in right jugular vein. We report a case of 28 years old female patient presented in our emergency with history of entrapped guide wire in right side of neck during CVC. X-ray showed coiling of guide wire in neck. CT Angiography showed guide wire coursing in between common carotid artery and internal jugular vein (IJV), closely abutting the wall of both vessels. The guide wire was coiled with end coursing behind the esophageal wall. Guide wire was removed under fluoroscopic guide manipulation under local anesthesia. We want to emphasize that even though CVC placement is common and simple procedure, serious complication can occur in hands of untrained operator. The procedure should be performed under supervision, if done by trainee. Force should never be applied to advance the guide wire if resistance is encountered.
Estimation of lung shunt fraction from simultaneous fluoroscopic and nuclear images
NASA Astrophysics Data System (ADS)
van der Velden, Sandra; Bastiaannet, Remco; Braat, Arthur J. A. T.; Lam, Marnix G. E. H.; Viergever, Max A.; de Jong, Hugo W. A. M.
2017-11-01
Radioembolisation with yttrium-90 (90Y) is increasingly used as a treatment of unresectable liver malignancies. For safety, a scout dose of technetium-99m macroaggregated albumin (99mTc-MAA) is used prior to the delivery of the therapeutic activity to mimic the deposition of 90Y. One-day procedures are currently limited by the lack of nuclear images in the intervention room. To cope with this limitation, an interventional simultaneous fluoroscopic and nuclear imaging device is currently being developed. The purpose of this simulation study was to evaluate the accuracy of estimating the lung shunt fraction (LSF) of the scout dose in the intervention room with this device and compare it against current clinical methods. Methods: A male and female XCAT phantom, both with two respiratory profiles, were used to simulate various LSFs resulting from a scout dose of 150 MBq 99mTc-MAA. Hybrid images were Monte Carlo simulated for breath-hold (5 s) and dynamic breathing (10 frames of 0.5 s) acquisitions. Nuclear images were corrected for attenuation with the fluoroscopic image and for organ overlap effects using a pre-treatment CT-scan. For comparison purposes, planar scintigraphy and mobile gamma camera images (both 300 s acquisition time) were simulated. Estimated LSFs were evaluated for all methods and compared to the phantom ground truth. Results: In the clinically relevant range of 10-20% LSF, hybrid imaging overestimated LSF with approximately 2 percentage points (pp) and 3 pp for the normal and irregular breathing phantoms, respectively. After organ overlap correction, LSF was estimated with a more constant error. Errors in planar scintigraphy and mobile gamma camera imaging were more dependent on LSF, body shape and breathing profile. Conclusion: LSF can be estimated with a constant minor error with a hybrid imaging device. Estimated LSF is highly dependent on true LSF, body shape and breathing pattern when estimated with current clinical methods. The hybrid imaging device is capable of accurately estimating LSF within a few seconds in an interventional setting.
Impact of Duplex arterial mapping on decision making in non-acute ischemic limb patients.
Elbadawy, A; Aly, H; Ibrahim, M; Bakr, H
2015-12-01
The aim of this study was to demonstrate the impact of Duplex arterial mapping on decision making in non-acute ischemic limb patient group reporting pain onset between 15 days and 3 months. We prospectively evaluated patients presented with critical limb ischemia who reported pain onset of duration between 15 days and 3 months in one-year period. Our series included thirty cases (mean age=61.3 years old), as Duplex arterial mapping was the sole preoperative imaging tool performed in all of them. All patients, in whom duplex indicated thrombosis in long occluded segments, were candidates for fluoroscopically guided thrombectomy. When Duplex defined chronic arterial occlusions, patients underwent endovascular or bypass revascularisation procedures. Impact of Duplex wall interrogation on decision-making between the two groups (subacute and chronic) was measured. Duplex arterial mapping categorized correctly all 30 patients into either subacute ischemia with removable clot (N.=14) or chronic ischemia (N.=16). Fluoroscopic guided thrombectomy was performed in 14 cases when Duplex advised long occluded arterial segments as indicted by intact intima with echogenic thrombus inside. Bypass surgery was performed in 8 patients. Percutaneous transluminal angioplasty (PTA) was done in 7 cases and thrombendartrectomy of common femoral artery in a single case. One-year patency rate in our series was 86.6%. It was 71.4% in thrombosis group. Limb salvage rate was 93.3%. Duplex arterial mapping could be used to differentiate the subacute ischemia with removable thrombus and chronic arterial occlusions guiding for the best revascularization procedure accordingly.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cazzato, Roberto Luigi, E-mail: gigicazzato@hotmail.it; Garnon, Julien, E-mail: juleiengarnon@gmail.com; Ramamurthy, Nitin, E-mail: nitin-ramamurthy@hotmail.com
ObjectiveTo describe a novel percutaneous image-guided technique using a large-bore biopsy system to retrieve foreign bodies (FBs) accidentally retained during non-vascular interventional procedures.Materials and MethodsBetween May 2013 and October 2015, five patients underwent percutaneous retrieval of five iatrogenic FBs, including a biopsy needle tip in the femoral head following osteoblastoma biopsy and radiofrequency ablation (RFA); a co-axial needle shaft within a giant desmoid tumour following cryoablation; and three post-vertebroplasty cement tails within paraspinal muscles. All FBs were retrieved immediately following original procedures under local or general anaesthesia, using combined computed tomography (CT) and fluoroscopic guidance. The basic technique involved positioningmore » a 6G trocar sleeve around the FB long axis and co-axially advancing an 8G biopsy needle to retrieve the FB within the biopsy core. Retrospective chart review facilitated analysis of procedures, FBs, technical success, and complications.ResultsMean FB size was 23 mm (range 8–74 mm). Four FBs were located within 10 mm of non-vascular significant anatomic structures. The basic technique was successful in 3 cases; 2 cases required technical modifications including using a stiff guide-wire to facilitate retrieval in the case of the post-cryoablation FB; and using the central mandrin of the 6G trocar to push a cement tract back into an augmented vertebra when initial retrieval failed. Overall technical success (FB retrieval or removal to non-hazardous location) was 100 %, with no complications.ConclusionPercutaneous image-guided retrieval of iatrogenic FBs using a large-bore biopsy system is a feasible, safe, effective, and versatile technique, with potential advantages over existing methods.« less
Lens of the eye dose calculation for neuro-interventional procedures and CBCT scans of the head
NASA Astrophysics Data System (ADS)
Xiong, Zhenyu; Vijayan, Sarath; Rana, Vijay; Jain, Amit; Rudin, Stephen; Bednarek, Daniel R.
2016-03-01
The aim of this work is to develop a method to calculate lens dose for fluoroscopically-guided neuro-interventional procedures and for CBCT scans of the head. EGSnrc Monte Carlo software is used to determine the dose to the lens of the eye for the projection geometry and exposure parameters used in these procedures. This information is provided by a digital CAN bus on the Toshiba Infinix C-Arm system which is saved in a log file by the real-time skin-dose tracking system (DTS) we previously developed. The x-ray beam spectra on this machine were simulated using BEAMnrc. These spectra were compared to those determined by SpekCalc and validated through measured percent-depth-dose (PDD) curves and half-value-layer (HVL) measurements. We simulated CBCT procedures in DOSXYZnrc for a CTDI head phantom and compared the surface dose distribution with that measured with Gafchromic film, and also for an SK150 head phantom and compared the lens dose with that measured with an ionization chamber. Both methods demonstrated good agreement. Organ dose calculated for a simulated neuro-interventional-procedure using DOSXYZnrc with the Zubal CT voxel phantom agreed within 10% with that calculated by PCXMC code for most organs. To calculate the lens dose in a neuro-interventional procedure, we developed a library of normalized lens dose values for different projection angles and kVp's. The total lens dose is then calculated by summing the values over all beam projections and can be included on the DTS report at the end of the procedure.
McLeod, Helen; Cox, Ben F; Robertson, James; Duncan, Robyn; Matthew, Shona; Bhat, Raj; Barclay, Avril; Anwar, J; Wilkinson, Tracey; Melzer, Andreas; Houston, J Graeme
2017-09-01
The purpose of this investigation was to evaluate human Thiel-embalmed cadavers with the addition of extracorporeal driven ante-grade pulsatile flow in the aorta as a model for simulation training in interventional techniques and endovascular device testing. Three human cadavers embalmed according to the method of Thiel were selected. Extracorporeal pulsatile ante-grade flow of 2.5 L per min was delivered directly into the aorta of the cadavers via a surgically placed connection. During perfusion, aortic pressure and temperature were recorded and optimized for physiologically similar parameters. Pre- and post-procedure CT imaging was conducted to plan and follow up thoracic and abdominal endovascular aortic repair as it would be in a clinical scenario. Thoracic endovascular aortic repair (TEVAR) and endovascular abdominal repair (EVAR) procedures were conducted in simulation of a clinical case, under fluoroscopic guidance with a multidisciplinary team present. The Thiel cadaveric aortic perfusion model provided pulsatile ante-grade flow, with pressure and temperature, sufficient to conduct a realistic simulation of TEVAR and EVAR procedures. Fluoroscopic imaging provided guidance during the intervention. Pre- and post-procedure CT imaging facilitated planning and follow-up evaluation of the procedure. The human Thiel-embalmed cadavers with the addition of extracorporeal flow within the aorta offer an anatomically appropriate, physiologically similar robust model to simulate aortic endovascular procedures, with potential applications in interventional radiology training and medical device testing as a pre-clinical model.
Reduced-dose C-arm computed tomography applications at a pediatric institution.
Acord, Michael; Shellikeri, Sphoorti; Vatsky, Seth; Srinivasan, Abhay; Krishnamurthy, Ganesh; Keller, Marc S; Cahill, Anne Marie
2017-12-01
Reduced-dose C-arm computed tomography (CT) uses flat-panel detectors to acquire real-time 3-D images in the interventional radiology suite to assist with anatomical localization and procedure planning. To describe dose-reduction techniques for C-arm CT at a pediatric institution and to provide guidance for implementation. We conducted a 5-year retrospective study on procedures using an institution-specific reduced-dose protocol: 5 or 8 s Dyna Rotation, 248/396 projection images/acquisition and 0.1-0.17 μGy/projection dose at the detector with 0.3/0.6/0.9-mm copper (Cu) filtration. We categorized cases by procedure type and average patient age and calculated C-arm CT and total dose area product (DAP). Two hundred twenty-two C-arm CT-guided procedures were performed with a dose-reduction protocol. The most common procedures were temporomandibular and sacroiliac joint injections (48.6%) and sclerotherapy (34.2%). C-arm CT was utilized in cases of difficult percutaneous access in less common applications such as cecostomy and gastrostomy placement, foreign body retrieval and thoracentesis. C-arm CT accounted for between 9.9% and 80.7% of the total procedural DAP. Dose-reducing techniques can preserve image quality for intervention while reducing radiation exposure to the child. This technology has multiple applications within pediatric interventional radiology and can be considered as an adjunctive imaging tool in a variety of procedures, particularly when percutaneous access is challenging despite routine fluoroscopic or ultrasound guidance.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Miller, Donald L.; Hilohi, C. Michael; Spelic, David C.
2012-10-15
Purpose: To determine patient radiation doses from interventional cardiology procedures in the U.S and to suggest possible initial values for U.S. benchmarks for patient radiation dose from selected interventional cardiology procedures [fluoroscopically guided diagnostic cardiac catheterization and percutaneous coronary intervention (PCI)]. Methods: Patient radiation dose metrics were derived from analysis of data from the 2008 to 2009 Nationwide Evaluation of X-ray Trends (NEXT) survey of cardiac catheterization. This analysis used deidentified data and did not require review by an IRB. Data from 171 facilities in 30 states were analyzed. The distributions (percentiles) of radiation dose metrics were determined for diagnosticmore » cardiac catheterizations, PCI, and combined diagnostic and PCI procedures. Confidence intervals for these dose distributions were determined using bootstrap resampling. Results: Percentile distributions (advisory data sets) and possible preliminary U.S. reference levels (based on the 75th percentile of the dose distributions) are provided for cumulative air kerma at the reference point (K{sub a,r}), cumulative air kerma-area product (P{sub KA}), fluoroscopy time, and number of cine runs. Dose distributions are sufficiently detailed to permit dose audits as described in National Council on Radiation Protection and Measurements Report No. 168. Fluoroscopy times are consistent with those observed in European studies, but P{sub KA} is higher in the U.S. Conclusions: Sufficient data exist to suggest possible initial benchmarks for patient radiation dose for certain interventional cardiology procedures in the U.S. Our data suggest that patient radiation dose in these procedures is not optimized in U.S. practice.« less
Dumenil, Aurélien; Kaladji, Adrien; Castro, Miguel; Esneault, Simon; Lucas, Antoine; Rochette, Michel; Goksu, Cemil; Haigron, Pascal
2013-01-01
Endovascular repair of abdominal aortic aneurysms is a well-established technique throughout the medical and surgical communities. Although increasingly indicated, this technique does have some limitations. Because intervention is commonly performed under fluoroscopic control, two-dimensional (2D) visualization of the aneurysm requires the injection of a contrast agent. The projective nature of this imaging modality inevitably leads to topographic errors, and does not give information on arterial wall quality at the time of deployment. A specially-adapted intraoperative navigation interface could increase deployment accuracy and reveal such information, which preoperative three-dimensional (3D) imaging might otherwise provide. One difficulty is the precise matching of preoperative data (images and models) and intraoperative observations affected by anatomical deformations due to tool-tissue interactions. Our proposed solution involves a finite element-based preoperative simulation of tool/tissue interactions, its adaptive tuning regarding patient specific data, and the matching with intra-operative data. The biomechanical model was first tuned on a group of 10 patients and assessed on a second group of 8 patients. PMID:23269745
Computerized lateral endoscopic approach to invertebral bodies
NASA Astrophysics Data System (ADS)
Abbasi, Hamid R.; Hariri, Sanaz; Kim, Daniel; Shahidi, Ramin; Steinberg, Gary
2001-05-01
Spinal surgery is often necessary to ease back pain symptoms. Neuronavigation (NN) allows the surgeon to localize the position of his instruments in 3D using pre- operative CT scans registered to intra-operative marker positions in cranial surgeries. However, this tool is unavailable in spinal surgeries for a variety of reasons. For example, because of the spine's many degrees of freedom and flexibility, the geometric relationship of the skin to the internal spinal anatomy is not fixed. Guided by the currently available imperfect 2D images, it is difficult for the surgeon to correct a patient's spinal anomaly; thus surgical relief of back pain is often only temporary. The Image Guidance Laborator's (IGL) goal is to combine the direct optical control of traditional endoscopy with the 3D orientation of NN. This powerful tool requires registration of the patient's anatomy to the surgical navigation system using internal landmarks rather than skin markers. Pre- operative CT scans matched with intraoperative fluoroscopic images can overcome the problem of spinal movement in NN registration. The combination of endoscopy with fluoroscopic registration of vertebral bodies in a NN system provides a 3D intra-operative navigational system for spinal neurosurgery to visualize the internal surgical environment from any orientation in real time. The accuracy of this system integration is being evaluated by assessing the success of nucleotomies and marker implantations guided by NN-registered endoscopy.
The financial impact of flipping the coin.
Gonzalez, Katherine W; Reddy, Shiva R; Mundakkal, Angela A; St Peter, Shawn D
2017-01-01
Esophageal foreign body retrieval is typically performed by rigid or flexible esophagoscopy. Despite evidence supporting the efficacy and safety of balloon extraction, it is rarely performed. We sought to establish the financial benefits of this minimally invasive approach. A retrospective review of 241 children with esophageal coins between 2011 and 2013 was performed. Coins were removed via endoscopy or fluoroscopic-guided balloon retrieval. Timing, symptoms, facility cost, and patient charges were compared. Two hundred patients had attempted balloon retrieval with 80% success. Forty-one patients went directly for operative removal. Patients with respiratory difficulty (p=0.05), wheezing (p<0.01), or fever (p=0.03) were more often taken directly for endoscopic retrieval. The median cost and charges for attempted balloon extraction were $484 and $1647. The median cost and charges for primary endoscopy were $1834 and $6746. The median total cost and charges of attempted balloon extraction including ED, OR, transport, admission, and balloon retrieval were $1231 and $3539 versus $3615 and $12,204 in the primary endoscopy group (p<0.001, p<0.001). Seventeen percent of patients who underwent attempted balloon retrieval were admitted prior to removal compared to 76% who underwent primary endoscopy (p<0.001). Fluoroscopic guided balloon extraction of esophageal coins is a financially prudent choice which shortens hospital stay. III. Retrospective treatment and economic study. Copyright © 2017 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kew, Jacqueline; Davies, Roger P.
2004-01-15
A new method is described for guiding hepato-portalvenous puncture using a longitudinal side-view intravascular ultrasound(L-IVUS) transducer to assist in the performance of transjugularintrahepatic portosystemic shunt (TIPS) in three Australian swine.Simultaneous L-IVUS with an AcuNav (registered) 5-10 MHz 10 Fr transducer(Acuson Corporation, Mountain View, CA, USA) and fluoroscopy guidance was used to image and monitor the hepatic to portal venous puncture,dilatation of the tract, and deployment of the TIPS stent. Flow through the shunt could be demonstrated with both L-IVUS and angiography. TIPS was successful in all swine. The time for portal vein puncture once the target portal vein was identifiedmore » was reduced at each attempt. The number of portal vein puncture attempts was 2, 1, and 1. No post-procedural complication was evident. L-IVUS-guided TIPS is practical and has the potential to improve safety by permitting simultaneous ultrasound and fluoroscopic imaging of the needle and target vascular structures. This technique allows for a more streamlined approach to TIPS, decreasing the fluoroscopic time (hence,decreasing the radiation exposure to the staff and patient) and anesthetic time. In addition, there are improved safety benefits obviating the need for wedged portography, facilitating avoidance of bile duct and hepatic arterial puncture, and minimizing hepatic injury by decreasing liver capsular puncture and the attendant risks.« less
Meess, Karen M.; Izzo, Richard L.; Dryjski, Maciej L.; Curl, Richard E.; Harris, Linda M.; Springer, Michael; Siddiqui, Adnan H.; Rudin, Stephen; Ionita, Ciprian N.
2017-01-01
Following new trends in precision medicine, Juxatarenal Abdominal Aortic Aneurysm (JAAA) treatment has been enabled by using patient-specific fenestrated endovascular grafts. The X-ray guided procedure requires precise orientation of multiple modular endografts within the arteries confirmed via radiopaque markers. Patient-specific 3D printed phantoms could familiarize physicians with complex procedures and new devices in a risk-free simulation environment to avoid periprocedural complications and improve training. Using the Vascular Modeling Toolkit (VMTK), 3D Data from a CTA imaging of a patient scheduled for Fenestrated EndoVascular Aortic Repair (FEVAR) was segmented to isolate the aortic lumen, thrombus, and calcifications. A stereolithographic mesh (STL) was generated and then modified in Autodesk MeshMixer for fabrication via a Stratasys Eden 260 printer in a flexible photopolymer to simulate arterial compliance. Fluoroscopic guided simulation of the patient-specific FEVAR procedure was performed by interventionists using all demonstration endografts and accessory devices. Analysis compared treatment strategy between the planned procedure, the simulation procedure, and the patient procedure using a derived scoring scheme. Results With training on the patient-specific 3D printed AAA phantom, the clinical team optimized their procedural strategy. Anatomical landmarks and all devices were visible under x-ray during the simulation mimicking the clinical environment. The actual patient procedure went without complications. Conclusions With advances in 3D printing, fabrication of patient specific AAA phantoms is possible. Simulation with 3D printed phantoms shows potential to inform clinical interventional procedures in addition to CTA diagnostic imaging. PMID:28638171
Meess, Karen M; Izzo, Richard L; Dryjski, Maciej L; Curl, Richard E; Harris, Linda M; Springer, Michael; Siddiqui, Adnan H; Rudin, Stephen; Ionita, Ciprian N
2017-02-11
Following new trends in precision medicine, Juxatarenal Abdominal Aortic Aneurysm (JAAA) treatment has been enabled by using patient-specific fenestrated endovascular grafts. The X-ray guided procedure requires precise orientation of multiple modular endografts within the arteries confirmed via radiopaque markers. Patient-specific 3D printed phantoms could familiarize physicians with complex procedures and new devices in a risk-free simulation environment to avoid periprocedural complications and improve training. Using the Vascular Modeling Toolkit (VMTK), 3D Data from a CTA imaging of a patient scheduled for Fenestrated EndoVascular Aortic Repair (FEVAR) was segmented to isolate the aortic lumen, thrombus, and calcifications. A stereolithographic mesh (STL) was generated and then modified in Autodesk MeshMixer for fabrication via a Stratasys Eden 260 printer in a flexible photopolymer to simulate arterial compliance. Fluoroscopic guided simulation of the patient-specific FEVAR procedure was performed by interventionists using all demonstration endografts and accessory devices. Analysis compared treatment strategy between the planned procedure, the simulation procedure, and the patient procedure using a derived scoring scheme. With training on the patient-specific 3D printed AAA phantom, the clinical team optimized their procedural strategy. Anatomical landmarks and all devices were visible under x-ray during the simulation mimicking the clinical environment. The actual patient procedure went without complications. With advances in 3D printing, fabrication of patient specific AAA phantoms is possible. Simulation with 3D printed phantoms shows potential to inform clinical interventional procedures in addition to CTA diagnostic imaging.
NASA Astrophysics Data System (ADS)
Meess, Karen M.; Izzo, Richard L.; Dryjski, Maciej L.; Curl, Richard E.; Harris, Linda M.; Springer, Michael; Siddiqui, Adnan H.; Rudin, Stephen; Ionita, Ciprian N.
2017-03-01
Following new trends in precision medicine, Juxatarenal Abdominal Aortic Aneurysm (JAAA) treatment has been enabled by using patient-specific fenestrated endovascular grafts. The X-ray guided procedure requires precise orientation of multiple modular endografts within the arteries confirmed via radiopaque markers. Patient-specific 3D printed phantoms could familiarize physicians with complex procedures and new devices in a risk-free simulation environment to avoid periprocedural complications and improve training. Using the Vascular Modeling Toolkit (VMTK), 3D Data from a CTA imaging of a patient scheduled for Fenestrated EndoVascular Aortic Repair (FEVAR) was segmented to isolate the aortic lumen, thrombus, and calcifications. A stereolithographic mesh (STL) was generated and then modified in Autodesk MeshMixer for fabrication via a Stratasys Eden 260 printer in a flexible photopolymer to simulate arterial compliance. Fluoroscopic guided simulation of the patient-specific FEVAR procedure was performed by interventionists using all demonstration endografts and accessory devices. Analysis compared treatment strategy between the planned procedure, the simulation procedure, and the patient procedure using a derived scoring scheme. Results: With training on the patient-specific 3D printed AAA phantom, the clinical team optimized their procedural strategy. Anatomical landmarks and all devices were visible under x-ray during the simulation mimicking the clinical environment. The actual patient procedure went without complications. Conclusions: With advances in 3D printing, fabrication of patient specific AAA phantoms is possible. Simulation with 3D printed phantoms shows potential to inform clinical interventional procedures in addition to CTA diagnostic imaging.
21 CFR 892.1650 - Image-intensified fluoroscopic x-ray system.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Image-intensified fluoroscopic x-ray system. 892... fluoroscopic x-ray system. (a) Identification. An image-intensified fluoroscopic x-ray system is a device intended to visualize anatomical structures by converting a pattern of x-radiation into a visible image...
21 CFR 892.1650 - Image-intensified fluoroscopic x-ray system.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Image-intensified fluoroscopic x-ray system. 892... fluoroscopic x-ray system. (a) Identification. An image-intensified fluoroscopic x-ray system is a device intended to visualize anatomical structures by converting a pattern of x-radiation into a visible image...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rauch, Phillip; Lin, Pei-Jan Paul; Balter, Stephen
2012-05-15
Task Group 125 (TG 125) was charged with investigating the functionality of fluoroscopic automatic dose rate and image quality control logic in modern angiographic systems, paying specific attention to the spectral shaping filters and variations in the selected radiologic imaging parameters. The task group was also charged with describing the operational aspects of the imaging equipment for the purpose of assisting the clinical medical physicist with clinical set-up and performance evaluation. Although there are clear distinctions between the fluoroscopic operation of an angiographic system and its acquisition modes (digital cine, digital angiography, digital subtraction angiography, etc.), the scope of thismore » work was limited to the fluoroscopic operation of the systems studied. The use of spectral shaping filters in cardiovascular and interventional angiography equipment has been shown to reduce patient dose. If the imaging control algorithm were programmed to work in conjunction with the selected spectral filter, and if the generator parameters were optimized for the selected filter, then image quality could also be improved. Although assessment of image quality was not included as part of this report, it was recognized that for fluoroscopic imaging the parameters that influence radiation output, differential absorption, and patient dose are also the same parameters that influence image quality. Therefore, this report will utilize the terminology ''automatic dose rate and image quality'' (ADRIQ) when describing the control logic in modern interventional angiographic systems and, where relevant, will describe the influence of controlled parameters on the subsequent image quality. A total of 22 angiography units were investigated by the task group and of these one each was chosen as representative of the equipment manufactured by GE Healthcare, Philips Medical Systems, Shimadzu Medical USA, and Siemens Medical Systems. All equipment, for which measurement data were included in this report, was manufactured within the three year period from 2006 to 2008. Using polymethylmethacrylate (PMMA) plastic to simulate patient attenuation, each angiographic imaging system was evaluated by recording the following parameters: tube potential in units of kilovolts peak (kVp), tube current in units of milliamperes (mA), pulse width (PW) in units of milliseconds (ms), spectral filtration setting, and patient air kerma rate (PAKR) as a function of the attenuator thickness. Data were graphically plotted to reveal the manner in which the ADRIQ control logic responded to changes in object attenuation. There were similarities in the manner in which the ADRIQ control logic operated that allowed the four chosen devices to be divided into two groups, with two of the systems in each group. There were also unique approaches to the ADRIQ control logic that were associated with some of the systems, and these are described in the report. The evaluation revealed relevant information about the testing procedure and also about the manner in which different manufacturers approach the utilization of spectral filtration, pulsed fluoroscopy, and maximum PAKR limitation. This information should be particularly valuable to the clinical medical physicist charged with acceptance testing and performance evaluation of modern angiographic systems.« less
Rauch, Phillip; Lin, Pei-Jan Paul; Balter, Stephen; Fukuda, Atsushi; Goode, Allen; Hartwell, Gary; LaFrance, Terry; Nickoloff, Edward; Shepard, Jeff; Strauss, Keith
2012-05-01
Task Group 125 (TG 125) was charged with investigating the functionality of fluoroscopic automatic dose rate and image quality control logic in modern angiographic systems, paying specific attention to the spectral shaping filters and variations in the selected radiologic imaging parameters. The task group was also charged with describing the operational aspects of the imaging equipment for the purpose of assisting the clinical medical physicist with clinical set-up and performance evaluation. Although there are clear distinctions between the fluoroscopic operation of an angiographic system and its acquisition modes (digital cine, digital angiography, digital subtraction angiography, etc.), the scope of this work was limited to the fluoroscopic operation of the systems studied. The use of spectral shaping filters in cardiovascular and interventional angiography equipment has been shown to reduce patient dose. If the imaging control algorithm were programmed to work in conjunction with the selected spectral filter, and if the generator parameters were optimized for the selected filter, then image quality could also be improved. Although assessment of image quality was not included as part of this report, it was recognized that for fluoroscopic imaging the parameters that influence radiation output, differential absorption, and patient dose are also the same parameters that influence image quality. Therefore, this report will utilize the terminology "automatic dose rate and image quality" (ADRIQ) when describing the control logic in modern interventional angiographic systems and, where relevant, will describe the influence of controlled parameters on the subsequent image quality. A total of 22 angiography units were investigated by the task group and of these one each was chosen as representative of the equipment manufactured by GE Healthcare, Philips Medical Systems, Shimadzu Medical USA, and Siemens Medical Systems. All equipment, for which measurement data were included in this report, was manufactured within the three year period from 2006 to 2008. Using polymethylmethacrylate (PMMA) plastic to simulate patient attenuation, each angiographic imaging system was evaluated by recording the following parameters: tube potential in units of kilovolts peak (kVp), tube current in units of milliamperes (mA), pulse width (PW) in units of milliseconds (ms), spectral filtration setting, and patient air kerma rate (PAKR) as a function of the attenuator thickness. Data were graphically plotted to reveal the manner in which the ADRIQ control logic responded to changes in object attenuation. There were similarities in the manner in which the ADRIQ control logic operated that allowed the four chosen devices to be divided into two groups, with two of the systems in each group. There were also unique approaches to the ADRIQ control logic that were associated with some of the systems, and these are described in the report. The evaluation revealed relevant information about the testing procedure and also about the manner in which different manufacturers approach the utilization of spectral filtration, pulsed fluoroscopy, and maximum PAKR limitation. This information should be particularly valuable to the clinical medical physicist charged with acceptance testing and performance evaluation of modern angiographic systems.
21 CFR 892.1660 - Non-image-intensified fluoroscopic x-ray system.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Non-image-intensified fluoroscopic x-ray system... fluoroscopic x-ray system. (a) Identification. A non-image-intensified fluoroscopic x-ray system is a device... of x-radiation into a visible image. This generic type of device may include signal analysis and...
21 CFR 892.1660 - Non-image-intensified fluoroscopic x-ray system.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Non-image-intensified fluoroscopic x-ray system... fluoroscopic x-ray system. (a) Identification. A non-image-intensified fluoroscopic x-ray system is a device... of x-radiation into a visible image. This generic type of device may include signal analysis and...
Semi-automated intra-operative fluoroscopy guidance for osteotomy and external-fixator.
Lin, Hong; Samchukov, Mikhail L; Birch, John G; Cherkashin, Alexander
2006-01-01
This paper outlines a semi-automated intra-operative fluoroscopy guidance and monitoring approach for osteotomy and external-fixator application in orthopedic surgery. Intra-operative Guidance module is one component of the "LegPerfect Suite" developed for assisting the surgical correction of lower extremity angular deformity. The Intra-operative Guidance module utilizes information from the preoperative surgical planning module as a guideline to overlay (register) its bone outline semi-automatically with the bone edge from the real-time fluoroscopic C-Arm X-Ray image in the operating room. In the registration process, scaling factor is obtained automatically through matching a fiducial template in the fluoroscopic image and a marker in the module. A triangle metal plate, placed on the operating table is used as fiducial template. The area of template image within the viewing area of the fluoroscopy machine is obtained by the image processing techniques such as edge detection and Hough transformation to extract the template from other objects in the fluoroscopy image. The area of fiducial template from fluoroscopic image is then compared with the area of the marker from the planning so as to obtain the scaling factor. After the scaling factor is obtained, the user can use simple operations by mouse to shift and rotate the preoperative planning to overlay the bone outline from planning with the bone edge from fluoroscopy image. In this way osteotomy levels and external fixator positioning on the limb can guided by the computerized preoperative plan.
Detection and Prevention of G-Induced Regional Atelectasis, Edema, and Hypoperfusion.
1975-12-01
Venous admixture in the pulmonary circulation of anesthetized dogs. J Appl Physiol 15:418 (1960). 13. Fowler, W. S., E. R. Cornish, Jr., and S. S...rebreathing method. J Clin Invest 38: 2073-2086 (1959). 18. Mead, J., and C. Collier. Relation of volume history of lungs to respiratory mechanics in... catheterization room for fluoroscopic studies, if these are required. A footrest (Fig. 1, point h), guided by stainless-steel tracks at the base of the table, is
Bas, Ahmet; Gülşen, Fatih; Emre, Senol; Samanci, Cesur; Uzunlu, Osman; Cantasdemir, Murat; Emir, Haluk; Numan, Furuzan
2015-12-01
Percutaneous nephrostomy (PCN) catheters are placed under combined ultrasound and fluoroscopic guidance in the interventional radiology suite and present unique challenges in neonates and infants. The purpose of this study was to demonstrate feasibility of PCN using a "14-4" (trocar and cannula) technique on neonates and infants. Between September 2009 and June 2014, data for 27 kidneys from consecutive 22 neonates or infants who underwent PCN catheter placement using the "14-4" technique were retrospectively analyzed. The median age at the time of placement of the PCN catheters was 11 days (range 5-300 days). There were 18 males and 4 females. All procedures were performed in the interventional radiology suite but without using fluoroscopy. Unilateral PCN was performed on 17 out of 22 patients, while bilateral drainage was performed on five patients. The technical success rate was 100%. The median duration of PCN catheter was 75 days (range 10-138 days). Minor macroscopic hematuria not requiring blood transfusion was present in two of the patients in which the hematuria lasted in 2 days. Placement of PCN catheters using a "14-4" technique with ultrasound as the sole imaging modality is a technically feasible and desirable option for neonates or infants. The technique obviates the need for ionizing radiation and potentially could be performed in the ultrasound room or even at the bedside.
Manchikanti, Laxmaiah; Cash, Kim A; Moss, Tammy L; Rivera, Jose; Pampati, Vidyasagar
2003-08-06
BACKGROUND: Fluoroscopic guidance is frequently utilized in interventional pain management. The major purpose of fluoroscopy is correct needle placement to ensure target specificity and accurate delivery of the injectate. Radiation exposure may be associated with risks to physician, patient and personnel. While there have been many studies evaluating the risk of radiation exposure and techniques to reduce this risk in the upper part of the body, the literature is scant in evaluating the risk of radiation exposure in the lower part of the body. METHODS: Radiation exposure risk to the physician was evaluated in 1156 patients undergoing interventional procedures under fluoroscopy by 3 physicians. Monitoring of scattered radiation exposure in the upper and lower body, inside and outside the lead apron was carried out. RESULTS: The average exposure per procedure was 12.0 PlusMinus; 9.8 seconds, 9.0 PlusMinus; 0.37 seconds, and 7.5 PlusMinus; 1.27 seconds in Groups I, II, and III respectively. Scatter radiation exposure ranged from a low of 3.7 PlusMinus; 0.29 seconds for caudal/interlaminar epidurals to 61.0 PlusMinus; 9.0 seconds for discography. Inside the apron, over the thyroid collar on the neck, the scatter radiation exposure was 68 mREM in Group I consisting of 201 patients who had a total of 330 procedures with an average of 0.2060 mREM per procedure and 25 mREM in Group II consisting of 446 patients who had a total of 662 procedures with average of 0.0378 mREM per procedure. The scatter radiation exposure was 0 mREM in Group III consisting of 509 patients who had a total 827 procedures. Increased levels of exposures were observed in Groups I and II compared to Group III, and Group I compared to Group II.Groin exposure showed 0 mREM exposure in Groups I and II and 15 mREM in Group III. Scatter radiation exposure for groin outside the apron in Group I was 1260 mREM and per procedure was 3.8182 mREM. In Group II the scatter radiation exposure was 400 mREM and with 0.6042 mREM per procedure. In Group III the scatter radiation exposure was 1152 mREM with 1.3930 mREM per procedure. CONCLUSION: Results of this study showed that scatter radiation exposure to both the upper and lower parts of the physician's body is present. Protection was offered by traditional measures to the upper body only.
Manchikanti, Laxmaiah; Malla, Yogesh; Wargo, Bradley W; Cash, Kimberly A; Pampati, Vidyasagar; Fellows, Bert
2012-01-01
Chronic spinal pain is common along with numerous modalities of diagnostic and therapeutic interventions utilized, creating a health care crisis. Facet joint injections and epidural injections are the 2 most commonly utilized interventions in managing chronic spinal pain. While the literature addressing the effectiveness of facet joint nerve blocks is variable and emerging, there is paucity of literature on adverse effects of facet joint nerve blocks. A prospective, non-randomized study of patients undergoing interventional techniques from May 2008 to December 2009. A private interventional pain management practice, a specialty referral center in the United States. Investigation of the incidence in characteristics of adverse effects and complications of facet joint nerve blocks. The study was carried out over a period of 20 months including almost 7,500 episodes of 43,000 facet joint nerve blocks with 3,370 episodes in the cervical region, 3,162 in the lumbar region, and 950 in the thoracic region. All facet joint nerve blocks were performed under fluoroscopic guidance in an ambulatory surgery center by 3 physicians. The complications encountered during the procedure and postoperatively were evaluated prospectively. This study was carried out over a period of 20 months and included over 7,500 episodes or 43,000 facet joint nerve blocks. All of the interventions were performed under fluoroscopic guidance in an ambulatory surgery center by one of 3 physicians. The complications encountered during the procedure and postoperatively were prospectively evaluated. Measurable outcomes employed were intravascular entry of the needle, profuse bleeding, local hematoma, dural puncture and headache, nerve root or spinal cord irritation with resultant injury, and infectious complications. There were no major complications. Multiple side effects and complications observed included overall intravascular penetration in 11.4% of episodes with 20% in cervical region, 4% in lumbar region, and 6% in thoracic region; local bleeding in 76.3% of episodes with highest in thoracic region and lowest in cervical region; oozing with 19.6% encounters with highest in cervical region and lowest in lumbar region; with local hematoma seen only in 1.2% of the patients with profuse bleeding, bruising, soreness, nerve root irritation, and all other effects such as vasovagal reactions observed in 1% or less of the episodes. Limitations of this study include lack of contrast injection, use of intermittent fluoroscopy and also an observational nature of the study. This study illustrate that major complications are extremely rare and minor side effects are common.
Ultrasound guided transrectal catheter drainage of pelvic collections.
Thakral, Anuj; Sundareyan, Ramaniwas; Kumar, Sheo; Arora, Divya
2015-01-01
The transrectal approach to draining deep-seated pelvic collections may be used to drain The transrectal approach to draining deep-seated pelvic collections may be used to drain intra-abdominal collections not reached by the transabdominal approach. We discuss 6 patients with such pelvic collections treated with transrectal drainage using catheter placement via Seldinger technique. Transrectal drainage helped achieve clinical and radiological resolution of pelvic collections in 6 and 5 of 6 cases, respectively. It simultaneously helped avoid injury to intervening bowel loops and neurovascular structures using real-time visualization of armamentarium used for drainage. Radiation exposure from fluoroscopic/CT guidance was avoided. Morbidity and costs incurred in surgical exploration were reduced using this much less invasive ultrasound guided transrectal catheter drainage of deep-seated pelvic collections.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Houston, J. Graeme; Anderson, David; Mills, John
2000-03-15
Purpose: To assess the technical success and early outcome of fluoroscopically guided transcervical fallopian tube recanalization (FTR) in mid-tubal occlusion following sterilization reversal surgery.Methods: From July 1995 to January 1998, patients with greater than 12 months secondary infertility underwent hysterosalpingography (HSG). FTR was performed in proximal or mid-tubal occlusion. Cases of FTR in mid-tubal occlusion were included in this study. Technical success (defined as complete tubal patency) using a standard guidewire and hydrophilic glidewire, the number of patients with at least one patent tube, and the intrauterine and ectopic pregnancy rates were determined.Results: Twenty-six infertile patients with previous sterilization reversalmore » underwent HSG. Eight of 26 (31%) patients (mean age 32 years, range 23-37 years), had attempted FTR for mid-tubal occlusion at the site of surgical anastomosis. Fourteen tubes were attempted as there were two previous salpingectomies. Technical success was achieved in eight of 14 (57%) tubes attempted, resulting in five of eight (62%) patients having at least one patent tube. At follow-up (mean 18 months, range 12-28 months) in these five patients there was one intrauterine pregnancy. There were no ectopic pregnancies.Conclusions: FTR in mid-tubal obstruction in infertile patients following sterilization reversal surgery is technically feasible and may result in intrauterine pregnancy. In this small group there was a lower technical success rate and lower pregnancy rate than in unselected proximal tubal occlusion.« less
Baur, Christoph; Milletari, Fausto; Belagiannis, Vasileios; Navab, Nassir; Fallavollita, Pascal
2016-07-01
Catheter guidance is a vital task for the success of electrophysiology interventions. It is usually provided through fluoroscopic images that are taken intra-operatively. The cardiologists, who are typically equipped with C-arm systems, scan the patient from multiple views rotating the fluoroscope around one of its axes. The resulting sequences allow the cardiologists to build a mental model of the 3D position of the catheters and interest points from the multiple views. We describe and compare different 3D catheter reconstruction strategies and ultimately propose a novel and robust method for the automatic reconstruction of 3D catheters in non-synchronized fluoroscopic sequences. This approach does not purely rely on triangulation but incorporates prior knowledge about the catheters. In conjunction with an automatic detection method, we demonstrate the performance of our method compared to ground truth annotations. In our experiments that include 20 biplane datasets, we achieve an average reprojection error of 0.43 mm and an average reconstruction error of 0.67 mm compared to gold standard annotation. In clinical practice, catheters suffer from complex motion due to the combined effect of heartbeat and respiratory motion. As a result, any 3D reconstruction algorithm via triangulation is imprecise. We have proposed a new method that is fully automatic and highly accurate to reconstruct catheters in three dimensions.
Silvestri, Enzo; Barile, Antonio; Albano, Domenico; Messina, Carmelo; Orlandi, Davide; Corazza, Angelo; Zugaro, Luigi; Masciocchi, Carlo; Sconfienza, Luca Maria
2018-04-01
To perform an online survey among all members of the Italian College of Musculoskeletal Radiology to understand how therapeutic musculoskeletal procedures are performed in daily practice in Italy. We administered an online survey to all 2405 members about the use of therapeutic musculoskeletal procedures in their institutions asking 16 different questions. Subgroup analysis was performed between general and orthopaedic hospitals with Mann-Whitney U and χ 2 statistics. A total of 129/2405 answers (5.4% of members) were included in our analysis. A median of 142.5 (25th-75th percentiles: 50-535.5; range 10-5000) therapeutic musculoskeletal procedures per single institution was performed in 2016. Arthropathic pain was the main indication. The most common procedures were joint injection, bursal/tendon injection, and irrigation of calcific tendinopathy. Ultrasound-guided procedures were mainly performed in ultrasonography rooms (77.4%) rather than in dedicated interventional rooms (22.6%). Conversely, fluoroscopic procedures were performed almost with the same frequency in interventional radiology suites (52.4%) and in general radiology rooms (47.6%). In most institutions (72%), autologous blood or components were not used. The median number of therapeutic musculoskeletal procedures performed in orthopaedic hospitals was significantly higher than in general hospitals (P = 0.002), as well as for the use of autologous preparations (P = 0.004). Joint injection, bursal/tendon injection, and irrigation of calcific tendinopathy were the most common therapeutic musculoskeletal procedures, being arthropathic pain the main indication. The percentage of procedures and the use of autologous preparations were significantly higher in orthopaedic hospitals than in general hospitals.
SU-F-I-71: Fetal Protection During Fluoroscopy: To Shield Or Not to Shield?
DOE Office of Scientific and Technical Information (OSTI.GOV)
Joshi, S; Vanderhoek, M
Purpose: Lead aprons are routinely used to shield the fetus from radiation during fluoroscopically guided interventions (FGI) involving pregnant patients. When placed in the primary beam, lead aprons often reduce image quality and increase fluoroscopic radiation output, which can adversely affect fetal dose. The purpose of this work is to identify an effective and practical method to reduce fetal dose without affecting image quality. Methods: A pregnant patient equivalent abdominal phantom is set on the table along with an image quality test object (CIRS model 903) representing patient anatomy of interest. An ion chamber is positioned at the x-ray beammore » entrance to the phantom, which is used to estimate the relative fetal dose. For three protective methods, image quality and fetal dose measurements are compared to baseline (no protection):1. Lead apron shielding the entire abdomen; 2. Lead apron shielding part of the abdomen, including the fetus; 3. Narrow collimation such that fetus is excluded from the primary beam. Results: With lead shielding the entire abdomen, the dose is reduced by 80% relative to baseline along with a drastic deterioration of image quality. With lead shielding only the fetus, the dose is reduced by 65% along with complete preservation of image quality, since the image quality test object is not shielded. However, narrow collimation results in 90% dose reduction and a slight improvement of image quality relative to baseline. Conclusion: The use of narrow collimation to protect the fetus during FGI is a simple and highly effective method that simultaneously reduces fetal dose and maintains sufficient image quality. Lead aprons are not as effective at fetal dose reduction, and if placed improperly, they can severely degrade image quality. Future work aims to investigate a wider variety of fluoroscopy systems to confirm these results across many different system geometries.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wallace, Adam N., E-mail: wallacea@mir.wustl.edu; Pacheco, Rafael A., E-mail: pachecor@mir.wustl.edu; Tomasian, Anderanik, E-mail: tomasiana@mir.wustl.edu
2016-02-15
BackgroundA novel coaxial biopsy system powered by a handheld drill has recently been introduced for percutaneous bone biopsy. This technical note describes our initial experience performing fluoroscopy-guided vertebral body biopsies with this system, compares the yield of drill-assisted biopsy specimens with those obtained using a manual technique, and assesses the histologic adequacy of specimens obtained with drill assistance.MethodsMedical records of all single-level, fluoroscopy-guided vertebral body biopsies were reviewed. Procedural complications were documented according to the Society of Interventional Radiology classification. The total length of bone core obtained from drill-assisted biopsies was compared with that of matched manual biopsies. Pathology reportsmore » were reviewed to determine the histologic adequacy of specimens obtained with drill assistance.ResultsTwenty eight drill-assisted percutaneous vertebral body biopsies met study inclusion criteria. No acute complications were reported. Of the 86 % (24/28) of patients with clinical follow-up, no delayed complications were reported (median follow-up, 28 weeks; range 5–115 weeks). The median total length of bone core obtained from drill-assisted biopsies was 28 mm (range 8–120 mm). This was longer than that obtained from manual biopsies (median, 20 mm; range 5–45 mm; P = 0.03). Crush artifact was present in 11 % (3/28) of drill-assisted biopsy specimens, which in one case (3.6 %; 1/28) precluded definitive diagnosis.ConclusionsA drill-assisted, coaxial biopsy system can be used to safely obtain vertebral body core specimens under fluoroscopic guidance. The higher bone core yield obtained with drill assistance may be offset by the presence of crush artifact.« less
NASA Astrophysics Data System (ADS)
Smith, Caleb Martin
Fluoroscopy guided procedures are increasing in complexity, and with that, Peak Skin Doses (PSD) that produce cutaneous radiation injury are a growing concern. Direct measurement of PSD is possible, but the decision to do so must be made in advance. PSD estimates and correctly monitoring their possible deterministic skin injuries are important to patient care. Three methods of indirect PSD estimation are examined for nine cases at MedStar Georgetown University Hospital. The aim of the study is to determine the magnitude of variation between these three methods for estimating the PSD. Method 1 (Fluoroscopy Time and Maximum Entrance Skin Exposure) was used at MedStar Georgetown University Hospital up until 2016. Methods 2 and 3 incorporate procedure information (Reference Point Air Kerma, Source-to-Patent distance, and Backscatter Factor) from DICOM (Digital Imaging and Communications in Medicine) tags into PSD estimates. Method 1 PSD estimates are vastly different, by as much as 136%, than those from Methods 2 and 3. Method 2 and 3 PSD estimates differ very little, 7.3% or less. Governing bodies have discounted Method 1 as a reliable dose metric because of its poor correlation with PSD. The accuracy of Method 2 is suitable to determine PSD and which dose band a patient fits so their injuries can be accurately monitored. Method 3, the most time intensive approach, should only be used in the case of a sentinel event where a full investigation is warranted.
A method of percutaneous vertebroplasty under the guidance of two C-arm fluoroscopes
Xu, Ren-Jie; Yan, Yong-Qing; Chen, Guang-Xiang; Zou, Tian-Ming; Cai, Xiao-Qiang; Wang, Dong-Lai
2014-01-01
Objective: To compare the clinical application in the percutaneous vertebroplasty under the guidance of one or two C-arm fluoroscopes. Methods: One hundred forty three elderly patients with Osteoporotic vertebral compression fractures (OVCFs) underwent percutaneous vertebroplasty under the guidance of one or two C-arm fluoroscopes. The number of pulsed imagings, the time of operation and the incidence of cement leakage were recorded. Results: The average number of pulsed imagings was 16.00±1.58 vs 13.07±2.00 per patient under the guidance of one vs two C-arm fluoroscopes. The average time of operation was 48.42±5.00 minutes vs 39.70±7.42 minutes per patient under the guidance of one vs two C-arm fluoroscopes. The incidence of cement leakage was 20% vs 15.7% of the patients under the guidance of one vs two C-arm fluoroscopes. The differences in the number of pulsed imagings and the time of operation were statistically significant. The difference in incidence of cement leakage was not statistically significant. Conclusion: The two-fluoroscopic technique reduce the labor cost, the radiation, the time of operation and the operation risk. PMID:24772138
NASA Astrophysics Data System (ADS)
Wagner, Martin G.; Strother, Charles M.; Schafer, Sebastian; Mistretta, Charles A.
2016-03-01
Biplane fluoroscopic imaging is an important tool for minimally invasive procedures for the treatment of cerebrovascular diseases. However, finding a good working angle for the C-arms of the angiography system as well as navigating based on the 2D projection images can be a difficult task. The purpose of this work is to propose a novel 4D reconstruction algorithm for interventional devices from biplane fluoroscopy images and to propose new techniques for a better visualization of the results. The proposed reconstruction methods binarizes the fluoroscopic images using a dedicated noise reduction algorithm for curvilinear structures and a global thresholding approach. A topology preserving thinning algorithm is then applied and a path search algorithm minimizing the curvature of the device is used to extract the 2D device centerlines. Finally, the 3D device path is reconstructed using epipolar geometry. The point correspondences are determined by a monotonic mapping function that minimizes the reconstruction error. The three dimensional reconstruction of the device path allows the rendering of virtual fluoroscopy images from arbitrary angles as well as 3D visualizations like virtual endoscopic views or glass pipe renderings, where the vessel wall is rendered with a semi-transparent material. This work also proposes a combination of different visualization techniques in order to increase the usability and spatial orientation for the user. A combination of synchronized endoscopic and glass pipe views is proposed, where the virtual endoscopic camera position is determined based on the device tip location as well as the previous camera position using a Kalman filter in order to create a smooth path. Additionally, vessel centerlines are displayed and the path to the target is highlighted. Finally, the virtual endoscopic camera position is also visualized in the glass pipe view to further improve the spatial orientation. The proposed techniques could considerably improve the workflow of minimally invasive procedures for the treatment of cerebrovascular diseases.
Fluoroscopy-Guided Endoscopic Removal of Foreign Bodies.
Kim, Junhwan; Ahn, Ji Yong; So, Seol; Lee, Mingee; Oh, Kyunghwan; Jung, Hwoon-Yong
2017-03-01
In most cases of ingested foreign bodies, endoscopy is the first treatment of choice. Moreover, emergency endoscopic removal is required for sharp and pointed foreign bodies such as animal or fish bones, food boluses, and button batteries due to the increased risks of perforation, obstruction, and bleeding. Here, we presented two cases that needed emergency endoscopic removal of foreign bodies without sufficient fasting time. Foreign bodies could not be visualized by endoscopy due to food residue; therefore, fluoroscopic imaging was utilized for endoscopic removal of foreign bodies in both cases.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bercu, Zachary L., E-mail: zachary.bercu@mountsinai.org; Sheth, Sachin B., E-mail: sachinsheth@gmail.com; Noor, Amir, E-mail: amir.noor@gmail.com
The creation of a transjugular intrahepatic portosystemic shunt (TIPS) is a critical procedure for the treatment of recurrent variceal bleeding and refractory ascites in the setting of portal hypertension. Chronic portal vein thrombosis remains a relative contraindication to conventional TIPS and options are limited in this scenario. Presented is a novel technique for management of refractory ascites in a patient with hepatitis C cirrhosis and chronic portal and superior mesenteric vein thrombosis secondary to schistosomiasis and lupus anticoagulant utilizing fluoroscopically guided percutaneous mesocaval shunt creation.
Hill, Kevin D; Frush, Donald P; Han, B Kelly; Abbott, Brian G; Armstrong, Aimee K; DeKemp, Robert A; Glatz, Andrew C; Greenberg, S Bruce; Herbert, Alexander Sheldon; Justino, Henri; Mah, Douglas; Mahesh, Mahadevappa; Rigsby, Cynthia K; Slesnick, Timothy C; Strauss, Keith J; Trattner, Sigal; Viswanathan, Mohan N; Einstein, Andrew J
2017-07-01
There is a need for consensus recommendations for ionizing radiation dose optimization during multimodality medical imaging in children with congenital and acquired heart disease (CAHD). These children often have complex diseases and may be exposed to a relatively high cumulative burden of ionizing radiation from medical imaging procedures, including cardiac computed tomography, nuclear cardiology studies, and fluoroscopically guided diagnostic and interventional catheterization and electrophysiology procedures. Although these imaging procedures are all essential to the care of children with CAHD and have contributed to meaningfully improved outcomes in these patients, exposure to ionizing radiation is associated with potential risks, including an increased lifetime attributable risk of cancer. The goal of these recommendations is to encourage informed imaging to achieve appropriate study quality at the lowest achievable dose. Other strategies to improve care include a patient-centered approach to imaging, emphasizing education and informed decision making and programmatic approaches to ensure appropriate dose monitoring. Looking ahead, there is a need for standardization of dose metrics across imaging modalities, so as to encourage comparative effectiveness studies across the spectrum of CAHD in children. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.
Partial lumbosacral transitional vertebra resection for contralateral facetogenic pain.
Brault, J S; Smith, J; Currier, B L
2001-01-15
Case report of surgically treated mechanical low back pain from the facet joint contralateral to a unilateral anomalous lumbosacral articulation (Bertolotti's syndrome). To describe the clinical presentation, diagnostic evaluation, and management of facet-related low back pain in a 17-year-old cheerleader and its successful surgical treatment with resection of a contralateral anomalous articulation. Lumbosacral transitional vertebrae are common in the general population. Bertolotti's syndrome is mechanical low back pain associated with these transitional segments. Little is known about the pathophysiology and mechanics of these vertebral segments and their propensity to be pain generators. Treatment of this syndrome is controversial, and surgical intervention has been infrequently reported. A retrospective chart analysis and radiographic review were performed. Repeated fluoroscopically guided injections implicated a symptomatic L6-S1 facet joint contralateral to an anomalous lumbosacral articulation. Eventually, a successful surgical outcome was achieved with resection of the anomalous articulation. Clinicians should consider the possibility that mechanical low back pain may occur from a facet contralateral to a unilateral anomalous lumbosacral articulation, even in a young patient. Although reports of surgical treatment of Bertolotti's syndrome are infrequent, resection of the anomalous articulation provided excellent results in this patient, presumably because of reduced stresses on the symptomatic facet.
Mattyasovszky, S G; Kurth, A A; Drees, P; Gemidji, J; Thomczyk, S; Kafchitsas, K
2014-10-01
Minimally invasive cement augmentation of painful osteoporotic vertebral compression fractures in elderly patients. Painful osteoporotic vertebral compression fractures in elderly patients (> 65 years of age) after conservative therapy failure. Painful aggressive primary tumors of the spine or osteolytic metastases to the spine with high risk of vertebral fracture in the palliative care setting. General contraindications for surgical interventions. Local soft-tissue infection. Osteomyelitis, discitis or systemic infection. Coagulopathy refractory to treatment or bleeding diathesis. Asymptomatic vertebral compression fractures. Burst of the posterior vertebral column with high degree of spinal canal stenosis. Primary or metastatic spinal tumors with epidural growth. Prone position on a radiolucent operating table. Fluoroscopic localization of the fractured vertebra using two conventional C-arm devices (anteroposterior and lateral views). Fluoroscopic localization of the fractured vertebra using two conventional C-arm devices (anteroposterior and lateral views). An introducer is inserted through a small skin incision into the pedicle under fluoroscopic guidance. To create a site- and size-specific three-dimensional cavity in the center of the fractured vertebra, the navigational VertecoR™ MidLine Osteotome was inserted through the correctly sited introducer and guided fluoroscopically. As the MidLine Osteotome allows angulation of the tip up to 90° by rotating the handle, a cavity over the midline of the vertebral body can mainly be created through one pedicle. The radiofrequency activated cohesive ultrahigh viscosity PMMA cement (ER(2) bone cement) is injected stepwise on demand by remote control under continuous pressure from the hydraulic assembly into the vertebral body. Bed rest for 6 h postoperatively in supine position. Early mobilization without a corset on the day of surgery. Specific back and abdominal exercises that strengthen the back and abdominal muscles. Pain dependent increase of weight bearing. Continue osteoporosis therapy and start specific drug therapy according to the local guidlines if necessary. In all, 44 patients (29 women, 15 men) with a mean age of 73.5 years with a total of 62 painful osteoporotic vertebral fractures were treated with RF kyphoplasty from May 2009 until July 2010, and followed over a period of 12 months. The mean operating time per patient was 36.2 min, the operating time per vertebra was 25.7 min. All the patients studied experienced an early and persistent significant pain relief even 12 months after therapy (8 ± 1.4 vs. 2.7 ± 1.9) according to the visual analogue pain scale. According to the Oswestry Disability Index (ODI) as a disease-specific disability measure all the patients improved significantly (p < 0.001) in the level of disability after operative treatment (56.2 ± 18.8 vs. 34.5 ± 16.6). Cement leakage was detected in 17 out of 62 (27.4 %) augmented vertebrae, whereas all the patients with cement leakage remained asymptomatic. One patient had subsequent vertebral fractures after a period of 6 months.
21 CFR 1020.32 - Fluoroscopic equipment.
Code of Federal Regulations, 2011 CFR
2011-04-01
... information as required in § 1020.30(h). (h) Fluoroscopic irradiation time, display, and signal. (1)(i... irradiation time of the fluoroscopic tube. The maximum cumulative time of the timing device shall not exceed 5... preset cumulative irradiation-time. Such signal shall continue to sound while x-rays are produced until...
21 CFR 1020.32 - Fluoroscopic equipment.
Code of Federal Regulations, 2013 CFR
2013-04-01
... information as required in § 1020.30(h). (h) Fluoroscopic irradiation time, display, and signal. (1)(i... irradiation time of the fluoroscopic tube. The maximum cumulative time of the timing device shall not exceed 5... preset cumulative irradiation-time. Such signal shall continue to sound while x-rays are produced until...
21 CFR 1020.32 - Fluoroscopic equipment.
Code of Federal Regulations, 2014 CFR
2014-04-01
... information as required in § 1020.30(h). (h) Fluoroscopic irradiation time, display, and signal. (1)(i... irradiation time of the fluoroscopic tube. The maximum cumulative time of the timing device shall not exceed 5... preset cumulative irradiation-time. Such signal shall continue to sound while x-rays are produced until...
21 CFR 1020.32 - Fluoroscopic equipment.
Code of Federal Regulations, 2012 CFR
2012-04-01
... information as required in § 1020.30(h). (h) Fluoroscopic irradiation time, display, and signal. (1)(i... irradiation time of the fluoroscopic tube. The maximum cumulative time of the timing device shall not exceed 5... preset cumulative irradiation-time. Such signal shall continue to sound while x-rays are produced until...
Inspecting Pipe Radiographically Through Asbestos Insulation
NASA Technical Reports Server (NTRS)
Gianettino, David P.
1994-01-01
Welds between sections of insulated steampipe located and inspected radiographically. Unless need to repair defective weld, one avoids cost, time, and hazard of removing asbestos insulation. Enables inspectors to locate and evaluate nondestructively any weld in pipe system, without shutting down steam. Hidden weld joints first located by use of low-power fluoroscope, moved along pipe while technician observes fluoroscopic image. Low-energy x rays from fluoroscope penetrate insulation but not pipe. Weld bead appears in silhouette on fluoroscope screen. Technician then accurately marks weld sites on insulation for later inspection.
Ko, Seulki; Chung, Hwan Hoon; Cho, Sung Bum; Jin, Young Woo; Kim, Kwang Pyo; Ha, Mina; Bang, Ye Jin; Ha, Yae Won; Lee, Won Jin
2017-12-15
Although fluoroscopically guided procedures involve a considerably high dose of radiation, few studies have investigated the effects of radiation on medical workers involved in interventional fluoroscopy procedures. Previous research remains in the early stages and has not reached a level comparable with other occupational studies thus far. Furthermore, the study of radiation workers provides an opportunity to estimate health risks at low doses and dose rates of ionising radiation. Therefore, the objectives of this study are (1) to initiate a prospective cohort study by conducting a baseline survey among medical radiation workers who involve interventional fluoroscopy procedures and (2) to assess the effect of occupational radiation exposure and on the overall health status through an in-depth cross-sectional study. Intervention medical workers in Korea will be enrolled by using a self-administered questionnaire survey, and the survey data will be linked with radiation dosimetry data, National Health Insurance claims data, cancer registry and mortality data. After merging these data, the radiation organ dose, lifetime attributable risk due to cancer and the risk per unit dose will be estimated. For the cross-sectional study, approximately 100 intervention radiology department workers will be investigated for blood tests, clinical examinations such as ultrasonography (thyroid and carotid artery scan) and lens opacity, the validation of badge dose and biodosimetry. This study was reviewed and approved by the institutional review board of Korea University (KU-IRB-12-12-A-1). All participants will provide written informed consent prior to enrolment. The findings of the study will be disseminated through peer-reviewed scientific journals, conference presentations, and a report will be submitted to the relevant public health authorities in the Korea Centers for Disease Control and Prevention to help with the development of appropriate research and management policies. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Ko, Seulki; Chung, Hwan Hoon; Cho, Sung Bum; Jin, Young Woo; Kim, Kwang Pyo; Ha, Mina; Bang, Ye Jin; Ha, Yae Won; Lee, Won Jin
2017-01-01
Introduction Although fluoroscopically guided procedures involve a considerably high dose of radiation, few studies have investigated the effects of radiation on medical workers involved in interventional fluoroscopy procedures. Previous research remains in the early stages and has not reached a level comparable with other occupational studies thus far. Furthermore, the study of radiation workers provides an opportunity to estimate health risks at low doses and dose rates of ionising radiation. Therefore, the objectives of this study are (1) to initiate a prospective cohort study by conducting a baseline survey among medical radiation workers who involve interventional fluoroscopy procedures and (2) to assess the effect of occupational radiation exposure and on the overall health status through an in-depth cross-sectional study. Methods and analysis Intervention medical workers in Korea will be enrolled by using a self-administered questionnaire survey, and the survey data will be linked with radiation dosimetry data, National Health Insurance claims data, cancer registry and mortality data. After merging these data, the radiation organ dose, lifetime attributable risk due to cancer and the risk per unit dose will be estimated. For the cross-sectional study, approximately 100 intervention radiology department workers will be investigated for blood tests, clinical examinations such as ultrasonography (thyroid and carotid artery scan) and lens opacity, the validation of badge dose and biodosimetry. Ethics and dissemination This study was reviewed and approved by the institutional review board of Korea University (KU-IRB-12-12-A-1). All participants will provide written informed consent prior to enrolment. The findings of the study will be disseminated through peer-reviewed scientific journals, conference presentations, and a report will be submitted to the relevant public health authorities in the Korea Centers for Disease Control and Prevention to help with the development of appropriate research and management policies. PMID:29248885
Zhu, Zhonglin; Li, Guoan
2013-01-01
Fluoroscopic image technique, using either a single image or dual images, has been widely applied to measure in vivo human knee joint kinematics. However, few studies have compared the advantages of using single and dual fluoroscopic images. Furthermore, due to the size limitation of the image intensifiers, it is possible that only a portion of the knee joint could be captured by the fluoroscopy during dynamic knee joint motion. In this paper, we presented a systematic evaluation of an automatic 2D–3D image matching method in reproducing spatial knee joint positions using either single or dual fluoroscopic image techniques. The data indicated that for the femur and tibia, their spatial positions could be determined with an accuracy and precision less than 0.2 mm in translation and less than 0.4° in orientation when dual fluoroscopic images were used. Using single fluoroscopic images, the method could produce satisfactory accuracy in joint positions in the imaging plane (average up to 0.5 mm in translation and 1.3° in rotation), but large variations along the out-plane direction (in average up to 4.0 mm in translation and 2.28 in rotation). The precision of using single fluoroscopic images to determine the actual knee positions was worse than its accuracy obtained. The data also indicated that when using dual fluoroscopic image technique, if the knee joint outlines in one image were incomplete by 80%, the algorithm could still reproduce the joint positions with high precisions. PMID:21806411
Uthayakumaran, Kalaichelvan; Subban, Vijayakumar; Lakshmanan, Anitha; Pakshirajan, Balaji; Solirajaram, Ramkumar; Krishnamoorthy, Jaishankar; Janakiraman, Ezhilan; Pandurangi, Ulhas M; Kalidoss, Latchumanadhas; Sankaradas, Mullasari Ajit
2014-01-01
To assess the technical challenges in percutaneous coronary intervention of Anomalous right coronary artery arising from the left sinus of valsalva. Between year 2008 and 2012, a total of 17 patients underwent PCI for an angiographically significant lesion in the right coronary artery of an anomalous origin in the LSOV. Their procedure details such as usage of catheters, radiation time, amount of contrast used were assessed. A total of 17 patients with anomalous right coronary artery underwent PCI during the above mentioned period. 8 patients had type A origin, 3 had type B origin and the remaining 6 had type C origin. Type A origin RCA were successfully cannulated in 6 patients with Judkins left 5.0 and in 2 patients using Judkins left 4.0. Extra back up (EBU) 3.5 were doing well in 2 patients of Type B origin and the remaining one patient was successfully cannulated using Judkins left 4.0. In type C origin 4 patients had successful cannulation with Amplatz Left 1.0, 1 patient with Amplatz Left 2.0 and 1 patient with Judkins left 4.0. The mean fluoroscopic time was 20.7 min and amount of contrast used was 210 ml. PCI of anomalous RCA origin from LSOV requires appropriate guide catheter selection according to the anatomy of origin for successful cannulation and to reduce the contrast usage and radiation exposure. Copyright © 2014. Published by Elsevier B.V.
NASA Astrophysics Data System (ADS)
Gong, Ren Hui; Jenkins, Brad; Sze, Raymond W.; Yaniv, Ziv
2014-03-01
The skills required for obtaining informative x-ray fluoroscopy images are currently acquired while trainees provide clinical care. As a consequence, trainees and patients are exposed to higher doses of radiation. Use of simulation has the potential to reduce this radiation exposure by enabling trainees to improve their skills in a safe environment prior to treating patients. We describe a low cost, high fidelity, fluoroscopy simulation system. Our system enables operators to practice their skills using the clinical device and simulated x-rays of a virtual patient. The patient is represented using a set of temporal Computed Tomography (CT) images, corresponding to the underlying dynamic processes. Simulated x-ray images, digitally reconstructed radiographs (DRRs), are generated from the CTs using ray-casting with customizable machine specific imaging parameters. To establish the spatial relationship between the CT and the fluoroscopy device, the CT is virtually attached to a patient phantom and a web camera is used to track the phantom's pose. The camera is mounted on the fluoroscope's intensifier and the relationship between it and the x-ray source is obtained via calibration. To control image acquisition the operator moves the fluoroscope as in normal operation mode. Control of zoom, collimation and image save is done using a keypad mounted alongside the device's control panel. Implementation is based on the Image-Guided Surgery Toolkit (IGSTK), and the use of the graphics processing unit (GPU) for accelerated image generation. Our system was evaluated by 11 clinicians and was found to be sufficiently realistic for training purposes.
Deep architecture neural network-based real-time image processing for image-guided radiotherapy.
Mori, Shinichiro
2017-08-01
To develop real-time image processing for image-guided radiotherapy, we evaluated several neural network models for use with different imaging modalities, including X-ray fluoroscopic image denoising. Setup images of prostate cancer patients were acquired with two oblique X-ray fluoroscopic units. Two types of residual network were designed: a convolutional autoencoder (rCAE) and a convolutional neural network (rCNN). We changed the convolutional kernel size and number of convolutional layers for both networks, and the number of pooling and upsampling layers for rCAE. The ground-truth image was applied to the contrast-limited adaptive histogram equalization (CLAHE) method of image processing. Network models were trained to keep the quality of the output image close to that of the ground-truth image from the input image without image processing. For image denoising evaluation, noisy input images were used for the training. More than 6 convolutional layers with convolutional kernels >5×5 improved image quality. However, this did not allow real-time imaging. After applying a pair of pooling and upsampling layers to both networks, rCAEs with >3 convolutions each and rCNNs with >12 convolutions with a pair of pooling and upsampling layers achieved real-time processing at 30 frames per second (fps) with acceptable image quality. Use of our suggested network achieved real-time image processing for contrast enhancement and image denoising by the use of a conventional modern personal computer. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
Momin, Eric N; Recinos, Pablo F; Coon, Alexander L; Rigamonti, Daniele
2010-06-01
Ventriculoatrial (VA) shunting is commonly used to treat hydrocephalus when ventriculoperitoneal shunting has failed. Placement of a VA shunt in patients with narrowing or occlusion of the central veins presents considerable difficulty because few imaging modalities exist to safely and reliably insert a guidewire or atrial catheter past the occlusion. We report the use of intraoperative venography to guide the placement of the distal portion of a VA shunt in a patient with a valve blocking the left brachiocephalic vein. A 42-year-old man with pseudotumor cerebri and a left ventriculoperitoneal shunt presented with severe headaches. He was diagnosed with partial distal shunt obstruction. Because of a history of failed attempts at ventriculoperitoneal shunting, conversion to a VA shunt via the left internal jugular vein was planned. Surgery was performed by using the standard technique until resistance was encountered when inserting a guidewire into the internal jugular vein. Intraoperative venography of the central veins was performed, which showed a large valve blocking progression of the guidewire in the left brachiocephalic vein. Using fluoroscopic guidance, a 0.035-inch guidewire was successfully directed through the vein past the obstruction and exchanged for a peel-away introducer. The distal shunt catheter was then inserted, and the correct position in the atrium was confirmed fluoroscopically. When obstruction of the central veins is found during a VA shunting procedure, intraoperative venography is a useful method to aid in the placement of the atrial catheter through the central veins.
Sugand, Kapil; Wescott, Robert A; Carrington, Richard; Hart, Alister; Van Duren, Bernard H
2018-05-10
Background and purpose - Simulation is an adjunct to surgical education. However, nothing can accurately simulate fluoroscopic procedures in orthopedic trauma. Current options for training with fluoroscopy are either intraoperative, which risks radiation, or use of expensive and unrealistic virtual reality simulators. We introduce FluoroSim, an inexpensive digital fluoroscopy simulator without the need for radiation. Patients and methods - This was a multicenter study with 26 surgeons in which everyone completed 1 attempt at inserting a guide-wire into a femoral dry bone using surgical equipment and FluoroSim. 5 objective performance metrics were recorded in real-time to assess construct validity. The surgeons were categorized based on the number of dynamic hip screws (DHS) performed: novices (< 10), intermediates (10-39) and experts (≥ 40). A 7-point Likert scale questionnaire assessed the face and content validity of FluoroSim. Results - Construct validity was present for 2 clinically validated metrics in DHS surgery. Experts and intermediates statistically significantly outperformed novices for tip-apex distance and for cut-out rate. Novices took the least number of radiographs. Face and content validity were also observed. Interpretation - FluoroSim discriminated between novice and intermediate or expert surgeons based on tip-apex distance and cut-out rate while demonstrating face and content validity. FluoroSim provides a useful adjunct to orthopedic training. Our findings concur with results from studies using other simulation modalities. FluoroSim can be implemented for education easily and cheaply away from theater in a safe and controlled environment.
Zhang, Qiu; Kong, De-yu; Li, Chun-jian; Chen, Bo; Jia, En-zhi; Chen, Lei-Lei; Jia, Qing-zhe; Dai, Zhen-hua; Zhu, Tian-tian; Chen, Jun; Liu, Jie; Zhu, Tie-bing; Yang, Zhi-jian; Cao, Ke-jiang
2013-02-01
To evaluate the feasibility, efficacy and safety of the percutaneous coronary intervention (PCI)guided by computed tomography (CT) coronary angiography derived roadmap and magnetic navigation system (MNS). During June 2011 and May 2012, thirty consecutive patients receiving elective PCI were enrolled, coronary artery disease was primarily diagnosed by dual-source CT coronary angiography (DSCT-CA) at outpatient clinic and successively proved by coronary artery angiography in the hospital. Target vessels from pre-procedure DSCT-CA were transferred to the magnetic navigation system, and consequently edited, reconstructed, and projected onto the live fluoroscopic screen as roadmap. Parameters including characters of the target lesions, time, contrast volume, radiation dosage for guidewire crossing, and complications of the procedure were recorded. Thirty patients with 36 lesions were recruited and intervened by PCI. Among the target lesions, sixteen were classified as type A, 11 as type B1, 8 as type B2, 1 as type C. The average length of the target lesions was (22.0 ± 9.8) mm, and the average stenosis of the target lesions was (81.3 ± 10.3)%. Under the guidance of CT roadmap and MNS, 36 target lesions were crossed by the magnetic guidewires, with a lesion crossing ratio of 100%. The time of placement of the magnetic guidewires was 92.5 (56.6 - 131.3) seconds. The contrast volume and the radiation dosage for guidewire placement were 0.0 (0.0 - 3.0) ml and 235.0 (123.5 - 395.1) µGym(2)/36.5 (21.3 - 67.8) mGy, respectively. Guidewires were successfully placed in 21 (58.3%) lesions without contrast agent. All enrolled vessels were successfully treated, and there were no MNS associated complications. It is feasible, effective and safe to initiate PCI under the guidance of CT derived roadmap and MNS. This method might be helpful for the guidewire placement in the treatment of total occlusions.
Thompson, Bradley F; Pingree, Matthew J; Qu, Wenchun; Murthy, Naveen S; Lachman, Nirusha; Hurdle, Mark Friedrich
2018-04-01
Ultrasound is rarely used for guiding lumbosacral epidural steroid injections due to its technical limitations. For example, sonographic imaging lacks the ability to confirm epidural spread and identify vascular uptake. The perceived risk that these limitations pose to human subjects has precluded any large scale clinical trials to date. To compare the accuracy of ultrasound versus fluoroscopic guidance for first sacral transforaminal epidural injections. Cadaveric comparative study using dichotomous outcomes. A fluoroscopy suite and anatomic laboratory at an academic medical center. Four unembalmed adult human cadavers with no history of spinal surgery. Eight sites were injected twice by one interventionalist, using fluoroscopic and ultrasound guidance. In the fluoroscopy arm, contrast spread was assessed using computed tomography. In the ultrasound arm, latex spread was assessed using gross anatomic dissection. Any visible evidence of epidural spread constituted a positive result. Comparison of the success of obtaining epidural contrast flow was the primary outcome measure. Secondary outcome measures included average duration, rate of intravascular uptake, and quantity of intravascular uptake. All injections performed in both the ultrasound arm and the fluoroscopy arm had positive epidural spread. The average duration was 3.03 minutes with fluoroscopy and 4.76 minutes with ultrasound. The rate of intravascular uptake was 37.5% with fluoroscopy and 50% with ultrasound. Within the ultrasound arm, greater intravascular spread and duration variability were recorded. Although ultrasonography can provide reliable image guidance for cannulating the first sacral foramen in cadavers, it would have limited clinical utility due to its inability to visualize relevant neurovascular structures deep to the osseus roof and exclude intravascular uptake. IV. Copyright © 2018 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.
Yu, Robinson K.; Ghodadra, Anish; Agarwal, Vikas
2016-01-01
Background Lumbar transforaminal epidural steroid injection is a common and effective tool for managing lumbar radicular pain, although accidental intravascular injection can rarely result in paralysis. The purpose of this study is to determine the safest needle tip position for computed tomography (CT)-guided lumbar transforaminal epidural steroid injections as determined by incidence of intravascular injection. Methods Three radiologists, in consensus, reviewed procedural imaging for consecutive CT-fluoroscopic lumbar transforaminal epidural steroid injections performed during a 16-month period. Intravascular injections were identified and categorized by needle tip position, vessel type injected, intravascular injection volume and procedural phase containing the intravascular injection. Pearson chi-square and logistic regression testing were used to assess differences between groups, as appropriate. Results Intravascular injections occurred in 9% (52/606) of injections. The intravascular injection rate was significantly lower (P<0.001) for extraforaminal needle position (0%, 0/109) compared to junctional (8%, 27/319) and foraminal (14%, 25/178) needle tip positions. Of the intravascular injections, 4% (2/52) were likely arterial, 35% (18/52) were likely venous, and 62% (32/52) were indeterminate for vessel type injected. 46% (24/52) of intravascular injections were large volume, 33% (17/52) were small volume, and 21% (11/52) were trace volume. 56% (29/52) of intravascular injections occurred with the contrast trial dose, 29% (15/52) with the steroid/analgesic cocktail, and 15% (8/52) with both. Conclusions An extraforaminal needle position for CT-fluoroscopic lumbar transforaminal epidural steroid injections decreases the risk of intravascular injection and therefore may be safer than other needle tip positions. PMID:28097241
Evaluation of low-dose limits in 3D-2D rigid registration for surgical guidance
NASA Astrophysics Data System (ADS)
Uneri, A.; Wang, A. S.; Otake, Y.; Kleinszig, G.; Vogt, S.; Khanna, A. J.; Gallia, G. L.; Gokaslan, Z. L.; Siewerdsen, J. H.
2014-09-01
An algorithm for intensity-based 3D-2D registration of CT and C-arm fluoroscopy is evaluated for use in surgical guidance, specifically considering the low-dose limits of the fluoroscopic x-ray projections. The registration method is based on a framework using the covariance matrix adaptation evolution strategy (CMA-ES) to identify the 3D patient pose that maximizes the gradient information similarity metric. Registration performance was evaluated in an anthropomorphic head phantom emulating intracranial neurosurgery, using target registration error (TRE) to characterize accuracy and robustness in terms of 95% confidence upper bound in comparison to that of an infrared surgical tracking system. Three clinical scenarios were considered: (1) single-view image + guidance, wherein a single x-ray projection is used for visualization and 3D-2D guidance; (2) dual-view image + guidance, wherein one projection is acquired for visualization, combined with a second (lower-dose) projection acquired at a different C-arm angle for 3D-2D guidance; and (3) dual-view guidance, wherein both projections are acquired at low dose for the purpose of 3D-2D guidance alone (not visualization). In each case, registration accuracy was evaluated as a function of the entrance surface dose associated with the projection view(s). Results indicate that images acquired at a dose as low as 4 μGy (approximately one-tenth the dose of a typical fluoroscopic frame) were sufficient to provide TRE comparable or superior to that of conventional surgical tracking, allowing 3D-2D guidance at a level of dose that is at most 10% greater than conventional fluoroscopy (scenario #2) and potentially reducing the dose to approximately 20% of the level in a conventional fluoroscopically guided procedure (scenario #3).
Overview of ICRP Committee 3: protection in medicine.
Vañó, E; Miller, D L; Rehani, M M
2016-06-01
Committee 3 of the International Commission on Radiological Protection (ICRP) develops recommendations and guidance for protection of patients, staff, and the public against radiation exposure when ionising radiation is used for medical diagnosis, therapy, or biomedical research. This paper presents a summary of the work that Committee 3 has accomplished over the past few years, and also describes its current work. The most recent reports published by the Commission that relate to radiological protection in medicine are 'Radiological protection in cone beam computed tomography' (Publication 129), 'Radiation dose to patients from radiopharmaceuticals: a compendium of current information related to frequently used substances' (Publication 128, in cooperation with Committee 2), 'Radiological protection in ion beam radiotherapy' (Publication 127), 'Radiological protection in paediatric diagnostic and interventional radiology' (Publication 121), 'Radiological protection in cardiology' (Publication 120), and 'Radiological protection in fluoroscopically guided procedures outside the imaging department' (Publication 117). A new report on diagnostic reference levels in medical imaging will provide specific advice for interventional radiology, digital imaging, computed tomography, nuclear medicine, paediatrics, and hybrid (multi-modality) imaging procedures, and is expected to be published in 2016. Committee 3 is also working on guidance for occupational radiological protection in brachytherapy, and on guidance on occupational protection issues in interventional procedures, paying particular attention to the 2011 Commission's recommendations on the occupational dose limit for the lens of the eye (Publication 118). Other reports in preparation deal with justification, radiological protection in therapy with radiopharmaceuticals, radiological protection in medicine as related to individual radiosusceptibility, appropriate use of effective dose (in cooperation with other Committees), and guidance for healthcare practitioners on radiological and patient protection. Committee 3 has also suggested specific priorities for research on radiological protection in medicine to the Commission. © The International Society for Prosthetics and Orthotics.
NASA Astrophysics Data System (ADS)
Bergeron, Jeffrey A.; Eskey, Cliff J.; Attawia, Mohammed; Patel, Samit J.; Ryan, Thomas P.; Pellegrino, Richard; Sutton, Jeffrey; Crombie, John; Paul, B. T.; Hoopes, P. J.
2005-04-01
Pathologic involvement of the basivertebral nerve, an intraosseous vertebral nerve found in humans and most mammalian species, may play a role in some forms of back pain. This study was designed to assess the feasibility and effects of the percutaneous delivery of radiofrequency (RF) energy to thermally ablate the basivertebral nerve in the lumbar vertebrae of mature sheep. Using fluoroscopic guidance, a RF bipolar device was placed and a thermal dose delivered to lumbar vertebral bodies in sheep. Post-treatment assessment included multiple magnetic resonance imaging (MRI) techniques and computed tomography (CT). These data were analyzed and correlated to histopathology and morphometry findings to describe the cellular and boney structural changes resulting from the treatment. Imaging modalities MRI and CT can be implemented to non-invasively describe treatment region and volume, marrow cellular effects, and bone density alterations immediately following RF treatment and during convalescence. Such imaging can be utilized to assess treatment effects and refine the thermal dose to vertebral body volume ratio used in treatment planning. This information will be used to improve the therapeutic ratio and develop a treatment protocol for human applications.
Spine epidural and sacroiliac joints injections--when and how to perform.
D'Orazio, Federico; Gregori, Lorenzo Maria; Gallucci, Massimo
2015-05-01
To review the state-of-the-art of image-guided techniques used to treat painful syndromes of the lower back, their indications, how they should be performed, their related risks and the expected results. We describe the actual standards about image-guided infiltrative therapies both on spine and on sacroiliac joints. Both spinal epidural and sacroiliac injections appear useful in a large percentage of treated patients to get control of the perceived pain. Performing these therapies under CT or fluoroscopic guidance is the best and safest way to obtain satisfactory results because it is possible to target the use of drugs directly to the involved painful structures. Image-guided injections of the epidural space and of the sacroiliac joints are effective techniques for the treatment of pain; their effectiveness is sometimes not lasting for long periods of time but considering the low associated risk when performed by trained personnel, they can be easily repeated. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Nagai, Yuichi; Kitagawa, Mayumi; Torii, Jun; Iwase, Takumi; Aso, Tomohiko; Ihara, Kanyu; Fujikawa, Mari; Takeuchi, Yumiko; Suzuki, Katsumi; Ishiguro, Takashi; Hara, Akio
2014-03-01
Recently, the double contrast technique in a gastrointestinal examination and the transbronchial lung biopsy in an examination for the respiratory system [1-3] have made a remarkable progress. Especially in the transbronchial lung biopsy, better quality of x-ray fluoroscopic images is requested because this examination is performed under a guidance of x-ray fluoroscopic images. On the other hand, various image processing methods [4] for x-ray fluoroscopic images have been developed as an x-ray system with a flat panel detector [5-7] is widely used. A recursive filtering is an effective method to reduce a random noise in x-ray fluoroscopic images. However it has a limitation for its effectiveness of a noise reduction in case of a moving object exists in x-ray fluoroscopic images because the recursive filtering is a noise reduction method by adding last few images. After recursive filtering a residual signal was produced if a moving object existed in x-ray images, and this residual signal disturbed a smooth procedure of the examinations. To improve this situation, new noise reduction method has been developed. The Adaptive Noise Reduction [ANR] is the brand-new noise reduction technique which can be reduced only a noise regardless of the moving object in x-ray fluoroscopic images. Therefore the ANR is a very suitable noise reduction method for the transbronchial lung biopsy under a guidance of x-ray fluoroscopic images because the residual signal caused of the moving object in x-ray fluoroscopic images is never produced after the ANR. In this paper, we will explain an advantage of the ANR by comparing of a performance between the ANR images and the conventional recursive filtering images.
Towards fluoroscopic respiratory gating for lung tumours without radiopaque markers
NASA Astrophysics Data System (ADS)
Berbeco, Ross I.; Mostafavi, Hassan; Sharp, Gregory C.; Jiang, Steve B.
2005-10-01
Due to the risk of pneumothorax, many clinicians are reluctant to implant radiopaque markers within patients' lungs for the purpose of radiographic or fluoroscopic tumour localization. We propose a method of gated therapy using fluoroscopic information without the implantation of radiopaque markers. The method presented here does not rely on any external motion signal either. Breathing phase information is found by analysing the fluoroscopic intensity fluctuations in the lung. As the lungs fill/empty, the radiological pathlength through them shortens/lengthens, giving brighter/darker fluoroscopic intensities. The phase information is combined with motion-enhanced template matching to turn the beam on when the tumour is in the desired location. A study based on patient data is presented to demonstrate the feasibility of this procedure. The resulting beam-on pattern is similar to that produced by an external gating system. The only discrepancies occur briefly and at the gate edges.
Park, Junghyun; Park, Hue Jung; Moon, Dong Eon; Sa, Gye Jeol; Kim, Young Hoon
2015-01-01
Sacroiliac intraarticular injection by the traditional technique can be challenging to perform when the joint is covered with osteophytes or is extremely narrow. To examine whether there is enough space for the needle to be advanced from the L5-S1 interspinous space to the upper one-third sacroiliac joint (SIJ) by magnetic resonance image (MRI) analysis as an alternative to fluoroscopically guided SIJ injection with the lower one-third joint technique, and to determine the feasibility of this novel technique in clinical practice. MRI analysis and observational study. An interventional pain management practice at a university hospital. We analyzed 200 axial T2-weighted MRIs between the L5 and S1 vertebrae of 100 consecutive patients. The following measurements were obtained on both sides: 1) the thickness of fat in the midline; 2) the distance between the midline (Point C) and the junction (Point A) of the skin and the imaginary line that connects the SIJ and the most medial cortex of the ilium; 3) the distance between the midline (Point C) and the junction (Point B) of the skin and the imaginary line that connects the SIJ and the L5 spinous process; 4) the distance between the SIJ and midline (Point C) on the skin, or between the SIJ and the midpoint (Point C') of the line from Point A to Point B; and 5) the angle between the sagittal line and the imaginary line that connects the SIJ and the midline on the skin. The upper one-third joint technique was performed to establish the feasibility of the alternative technique in 20 patients who had unsuccessful sacroiliac intraarticular injections using the lower one-third joint technique. The mean distances from the midline to Point A and to Point B were 21.9 ± 13.7 mm and 27.8 ± 13.6 mm, respectively. The mean distance between the SIJ and Point C (or Point C') was 81.0 ± 13.3 mm. The angle between the sagittal line and the imaginary line that connects the SIJ and the midline on the skin was 42.8 ± 5.1°. The success rate of sacroiliac intraarticular injections with the upper one-third joint technique was 90% (18/20). This was an observational study and lacked a control group. Sacroiliac intraarticular injections with the upper one-third joint technique are advisable when it is hard to perform them with the lower one-third joint technique.
Aspergillus meningitis and discitis from low-back procedures in an immunocompetent patient.
Kolbe, A B Larson; McKinney, A M; Kendi, A Tuba Karagulle; Misselt, D
2007-07-01
We present a case of an immunocompetent patient who developed Aspergillus meningitis, subsequent to discitis, presumed to be from an epidural steroid injection. Magnetic resonance imaging (MRI) of the lumbar spine confirmed the diagnosis of discitis. Fluoroscopic-guided aspiration of the disc showed growth of Aspergillus fumigatus. MRI of the brain revealed involvement of the right third cranial nerve. Repeat MRIs demonstrated multiple leptomeningeal masses consistent with granulomatous meningitis. Meningitis is a rare complication of discitis, discogram, or epidural steroid injection. Aspergillus usually only infects immunocompromised patients, but rarely can affect immunocompetent patients.
Editorial: ERCP-Related Radiation Cataractogenesis: Is It Time to Be Concerned?
Mekaroonkamol, Parit; Keilin, Steven
2017-05-01
With the growing number of fluoroscopic guided endoscopic procedures, radiation-related risk needs to be further assessed. Recent evidence indicates that radiation cataractogenesis occurs at a lower dose threshold than previously believed. While body aprons and thyroid shields are well-established standard protection during fluoroscopy, ocular safety and the use of protective eyewear are not as well defined. This prospective study answered two important questions: Does the standard body dosimeter provide an accurate ocular dosimetry? And what is the time of fluoroscopy needed to warrant using lens protection? It also raises the question whether current guidelines need to be updated.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Trumm, Christoph Gregor, E-mail: christoph.trumm@med.lmu.de; Rubenbauer, Bianca; Piltz, Stefan
We present a case of combined surgical screw placement and osteoplasty guided by computed tomography-fluoroscopy (CTF) in a 68-year-old man with unilateral osteolytic destruction and a pathological fracture of the iliosacral joint due to a metastasis from renal cell carcinoma. The patient experienced intractable lower back pain that was refractory to analgesia. After transarterial particle and coil embolization of the tumor-feeding vessels in the angiography unit, the procedure was performed under general anesthesia by an interdisciplinary team of interventional radiologists and trauma surgeons. Under intermittent single-shot CTF, two K wires were inserted into the left iliosacral joint from a lateralmore » transiliac approach at the S1 level followed by two self-tapping surgical screws. Continuous CTF was used for monitoring of the subsequent polymethylmethacrylate injection through two vertebroplasty cannulas for further stabilization of the screw threads within the osteolytic sacral ala. Both the screw placement and cement injection were successful, with no complications occurring during or after the procedure. With additional nonsteroidal anti-inflammatory and opioid medication, the patient reported a marked decrease in his lower back pain and was able to move independently again at the 3-month follow-up assessment. In our patient with intolerable back pain due to tumor destruction and consequent pathological fracture of the iliosacral joint, CTF-guided iliosacral screw placement combined with osteoplasty was successful with respect to joint stabilization and a reduction in the need for analgesic therapy.« less
The training and learning process of transseptal puncture using a modified technique.
Yao, Yan; Ding, Ligang; Chen, Wensheng; Guo, Jun; Bao, Jingru; Shi, Rui; Huang, Wen; Zhang, Shu; Wong, Tom
2013-12-01
As the transseptal (TS) puncture has become an integral part of many types of cardiac interventional procedures, its technique that was initial reported for measurement of left atrial pressure in 1950s, continue to evolve. Our laboratory adopted a modified technique which uses only coronary sinus catheter as the landmark to accomplishing TS punctures under fluoroscopy. The aim of this study is prospectively to evaluate the training and learning process for TS puncture guided by this modified technique. Guided by the training protocol, TS puncture was performed in 120 consecutive patients by three trainees without previous personal experience in TS catheterization and one experienced trainer as a controller. We analysed the following parameters: one puncture success rate, total procedure time, fluoroscopic time, and radiation dose. The learning curve was analysed using curve-fitting methodology. The first attempt at TS crossing was successful in 74 (82%), a second attempt was successful in 11 (12%), and 5 patients failed to puncture the interatrial septal finally. The average starting process time was 4.1 ± 0.8 min, and the estimated mean learning plateau was 1.2 ± 0.2 min. The estimated mean learning rate for process time was 25 ± 3 cases. Important aspects of learning curve can be estimated by fitting inverse curves for TS puncture. The study demonstrated that this technique was a simple, safe, economic, and effective approach for learning of TS puncture. Base on the statistical analysis, approximately 29 TS punctures will be needed for trainee to pass the steepest area of learning curve.
Analysis of Patients' X-ray Exposure in 146 Percutaneous Radiologic Gastrostomies.
Petersen, Tim-Ole; Reinhardt, Martin; Fuchs, Jochen; Gosch, Dieter; Surov, Alexey; Stumpp, Patrick; Kahn, Thomas; Moche, Michael
2017-09-01
Purpose Analysis of patient´s X-ray exposure during percutaneous radiologic gastrostomies (PRG) in a larger population. Materials and Methods Data of primary successful PRG-procedures, performed between 2004 and 2015 in 146 patients, were analyzed regarding the exposition to X-ray. Dose-area-product (DAP), dose-length-product (DLP) respectively, and fluoroscopy time (FT) were correlated with the used x-ray systems (Flatpanel Detector (FD) vs. Image Itensifier (BV)) and the necessity for periprocedural placement of a nasogastric tube. Additionally, the effective X-ray dose for PRG placement using fluoroscopy (DL), computed tomography (CT), and cone beam CT (CBCT) was estimated using a conversion factor. Results The median DFP of PRG-placements under fluoroscopy was 163 cGy*cm 2 (flat panel detector systems: 155 cGy*cm 2 ; X-ray image intensifier: 175 cGy*cm 2 ). The median DLZ was 2.2 min. Intraprocedural placement of a naso- or orogastric probe (n = 68) resulted in a significant prolongation of the median DLZ to 2.5 min versus 2 min in patients with an already existing probe. In addition, dose values were analyzed in smaller samples of patients in which the PRG was placed under CBCT (n = 7, median DFP = 2635 cGy*cm 2 ), or using CT (n = 4, median DLP = 657 mGy*cm). Estimates of the median DFP and DLP showed effective doses of 0.3 mSv for DL-assisted placements (flat panel detector 0.3 mSv, X-ray image converter 0.4 mSv), 7.9 mSv using a CBCT - flat detector, and 9.9 mSv using CT. This corresponds to a factor 26 of DL versus CBCT, or a factor 33 of DL versus CT. Conclusion In order to minimize X-ray exposure during PRG-procedures for patients and staff, fluoroscopically-guided interventions should employ flat detector systems with short transmittance sequences in low dose mode and with slow image frequency. Series recordings can be dispensed with. The intraprocedural placement of a naso- or orogastric probe significantly extends FT, but has little effect on the overall dose of the intervention. Due to the significantly higher X-ray exposure, the use of a CBCT as well as PRG-placements using CT should be limited to clinically absolutely necessary exceptions with strict indication. Key Points · Fluoroscopically-guided PRG placements are interventions with low X-ray exposure.. · X-ray exposure from fluoroscopy is lower using flat panel detector systems as compared to image intensifier systems.. · The concomitant placement of an oro- or nasogastric probe extends the fluoroscopy time.. · Gastric probe placement is worthwhile to prevent the premature use of the significantly radiation-intensive CT.. · The use of the C-arm CT or the CT increases the beam exposure by 26 or 33 times, respectively.. · The PRG placement using C-arm CT and CT should only be performed in exceptional cases.. Citation Format · Petersen TO, Reinhardt M, Fuchs J et al. Analysis of Patients' X-ray Exposure in 146 Percutaneous Radiologic Gastrostomies. Fortschr Röntgenstr 2017; 189: 820 - 827. © Georg Thieme Verlag KG Stuttgart · New York.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dhou, S; Cai, W; Hurwitz, M
Purpose: We develop a method to generate time varying volumetric images (3D fluoroscopic images) using patient-specific motion models derived from four-dimensional cone-beam CT (4DCBCT). Methods: Motion models are derived by selecting one 4DCBCT phase as a reference image, and registering the remaining images to it. Principal component analysis (PCA) is performed on the resultant displacement vector fields (DVFs) to create a reduced set of PCA eigenvectors that capture the majority of respiratory motion. 3D fluoroscopic images are generated by optimizing the weights of the PCA eigenvectors iteratively through comparison of measured cone-beam projections and simulated projections generated from the motionmore » model. This method was applied to images from five lung-cancer patients. The spatial accuracy of this method is evaluated by comparing landmark positions in the 3D fluoroscopic images to manually defined ground truth positions in the patient cone-beam projections. Results: 4DCBCT motion models were shown to accurately generate 3D fluoroscopic images when the patient cone-beam projections contained clearly visible structures moving with respiration (e.g., the diaphragm). When no moving anatomical structure was clearly visible in the projections, the 3D fluoroscopic images generated did not capture breathing deformations, and reverted to the reference image. For the subset of 3D fluoroscopic images generated from projections with visibly moving anatomy, the average tumor localization error and the 95th percentile were 1.6 mm and 3.1 mm respectively. Conclusion: This study showed that 4DCBCT-based 3D fluoroscopic images can accurately capture respiratory deformations in a patient dataset, so long as the cone-beam projections used contain visible structures that move with respiration. For clinical implementation of 3D fluoroscopic imaging for treatment verification, an imaging field of view (FOV) that contains visible structures moving with respiration should be selected. If no other appropriate structures are visible, the images should include the diaphragm. This project was supported, in part, through a Master Research Agreement with Varian Medical Systems, Inc, Palo Alto, CA.« less
Challenges in Interventional Radiology: The Pregnant Patient
Moon, Eunice K.; Wang, Weiping; Newman, James S.; Bayona-Molano, Maria Del Pilar
2013-01-01
A pregnant patient presenting to interventional radiology (IR) has a different set of needs from any other patient requiring a procedure. Often, the patient's care can be in direct conflict with the growth and development of the fetus, whether it be optimal fluoroscopic imaging, adequate sedation of the mother, or the timing of the needed procedure. Despite the additional risks and complexities associated with pregnancy, IR procedures can be performed safely for the pregnant patient with knowledge of the special and general needs of the pregnant patient, use of acceptable medications and procedures likely to be encountered during pregnancy, in addition to strategies to protect the patient and her fetus from the hazards of radiation. PMID:24436567
Patient doses from fluoroscopically guided cardiac procedures in pediatrics
NASA Astrophysics Data System (ADS)
Martinez, L. C.; Vano, E.; Gutierrez, F.; Rodriguez, C.; Gilarranz, R.; Manzanas, M. J.
2007-08-01
Infants and children are a higher risk population for radiation cancer induction compared to adults. Although some values on pediatric patient doses for cardiac procedures have been reported, data to determine reference levels are scarce, especially when compared to those available for adults in diagnostic and therapeutic procedures. The aim of this study is to make a new contribution to the scarce published data in pediatric cardiac procedures and help in the determination of future dose reference levels. This paper presents a set of patient dose values, in terms of air kerma area product (KAP) and entrance surface air kerma (ESAK), measured in a pediatric cardiac catheterization laboratory equipped with a biplane x-ray system with dynamic flat panel detectors. Cardiologists were properly trained in radiation protection. The study includes 137 patients aged between 10 days and 16 years who underwent diagnostic catheterizations or therapeutic procedures. Demographic data and technical details of the procedures were also gathered. The x-ray system was submitted to a quality control programme, including the calibration of the transmission ionization chamber. The age distribution of the patients was 47 for <1 year; 52 for 1-<5 years; 25 for 5-<10 years and 13 for 10-<16 years. Median values of KAP were 1.9, 2.9, 4.5 and 15.4 Gy cm2 respectively for the four age bands. These KAP values increase by a factor of 8 when moving through the four age bands. The probability of a fatal cancer per fluoroscopically guided cardiac procedure is about 0.07%. Median values of ESAK for the four age bands were 46, 50, 56 and 163 mGy, which lie far below the threshold for deterministic effects on the skin. These dose values are lower than those published in previous papers.
Tiegs-Heiden, C A; Murthy, N S; Geske, J R; Diehn, F E; Schueler, B A; Wald, J T; Kaufmann, T J; Lehman, V T; Carr, C M; Amrami, K K; Morris, J M; Thielen, K R; Maus, T P
2016-01-01
To investigate whether there are differences in fluoroscopy time and patient dose for fluoroscopically guided lumbar transforaminal epidural steroid injections (TFESIs) performed by staff radiologists versus with trainees and to evaluate the effect of patient body mass index (BMI) on fluoroscopy time and patient dose, including their interactions with other variables. Single-level lumbar TFESIs (n=1844) between 1 January 2011 and 31 December 2013 were reviewed. Fluoroscopy time, reference point air kerma (Ka,r), and kerma area product (KAP) were recorded. BMI and trainee involvement were examined as predictors of fluoroscopy time, Ka,r, and KAP in models adjusted for age and gender in multivariable linear models. Stratified models of BMI groups by trainee presence were performed. Increased age was the only significant predictor of increased fluoroscopy time (p<0.0001). Ka,r and KAP were significantly higher in patients with a higher BMI (p<0.0001 and p=0.0009). When stratified by BMI, longer fluoroscopy time predicted increased Ka,r and KAP in all groups (p<0.0001). Trainee involvement was not a statistically significant predictor of fluoroscopy time or Ka,r in any BMI category. KAP was lower with trainees in the overweight group (p=0.0009) and higher in male patients for all BMI categories (p<0.02). Trainee involvement did not result in increased fluoroscopy time or patient dose. BMI did not affect fluoroscopy time; however, overweight and obese patients received significantly higher Ka,r and KAP. Male patients received a higher KAP in all BMI categories. Limiting fluoroscopy time and good collimation practices should be reinforced in these patients. Copyright © 2015 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
Manchikanti, Laxmaiah; Singh, Vijay; Cash, Kimberly A; Pampati, Vidyasagar; Damron, Kim S; Boswell, Mark V
2012-01-01
Lumbar disc herniation and radiculitis are common elements of low back and lower extremity pain. Among minimally invasive treatments, epidural injections are one of the most commonly performed interventions. However, the literature is mixed about their effectiveness in managing low back and lower extremity pain. In general, individual studies and systematic reviews of epidural steroid injections have been hampered by their study design, baseline differences between treatment groups, inadequate sample sizes, highly controlled settings, lack of validated outcome measures, and the inability to confirm the injectate location because fluoroscopy was not used. A randomized, controlled, double blind, active control trial. A private, interventional pain management practice, specialty referral center in the United States. To assess the effectiveness of fluoroscopically directed caudal epidural injections with local anesthetic with or without steroids in managing chronic low back and lower extremity pain in patients with disc herniation and radiculitis. One hundred twenty patients were randomized to two groups: Group I received 10 mL caudal epidural injections of local anesthetic, lidocaine 0.5%; Group II patients received caudal epidural injections of 0.5% lidocaine, 9 mL, mixed with 1 mL of steroid. Multiple outcome measures were utilized. The primary outcome measures were Numeric Rating Scale (NRS) and the Oswestry Disability Index 2.0 (ODI). Secondary outcome measures were employment status and opioid intake. Significant pain relief improvement was defined as 50% or more improvement in NRS and ODI scores. In the successful category, 77% of Group I had significant pain relief of >/= 50% and functional status improvement of >/= 50% reduction in ODI scores; in Group II it was 76%, whereas overall it was 60% and 65% in Groups I and II. Over the two years, Group I had an average number of procedures of 5.5 ± 2.8; Group II was 5.3 ± 2.4. Even though there was no significant difference in overall relief between the two groups, the average relief for each procedure was superior for steroids. Presumed limitations of this evaluation include lack of a placebo group. Caudal epidural injections of local anesthetic with or without steroids might be an effective therapy for patients with disc herniation or radiculitis. The present evidence illustrates the potential superiority of steroids compared with local anesthetic at two year follow up based on average relief per procedure. NCT00370799.
Ionita, C; Loughran, B; Nagesh, S Setlur; Jain, A; Bednarek, D; Rudin, S
2012-06-01
The MAF is a new high-resolution detector which is being clinically evaluated in neuro-vascular procedures. The detector contains a large-dynamic-range, high-sensitivity light image intensifier with variable gain. Since the MAF is a research prototype only partially integrated with the clinical system, x-ray technique parameters must be set manually. To improve workflow we developed an automatic method to estimate and set the proper LII voltage (MAF gain) for DSA acquisition based on the fluoroscopic parameters. The detector entrance exposure (XD) can be written as the x-ray tube output exposure (Xo) times an object attenuation factor and an inverse-square correction. If the object attenuation, scatter and distances are unchanged and the effect of x-ray kVp changes are neglected, then the DSA XD can be expressed as the ratio of Xo(DSA)/Xo(Fluoroscopy) multiplied with XD(fluoroscopy). We measured Xo for fluoroscopy and DSA for mAs and kVp ranges appropriate to neuro- vascular interventions and fit the data with a 2D function. To estimate the XD(Fluoroscopy) we derived a curve of XD versus LII-voltage for a mid- dynamic-range average pixel gray-level. Since the MAF system during clinical fluoroscopy automatically adjusts the LII voltage until the desired gray-level value is achieved, by reading that voltage we can estimate the XD(Fluoroscopy). Using the 2D-fit function, Xo(DSA) is automatically calculated for the kVp and mA values set and XD(DSA) can be estimated using the relation above. Using the inverse LII calibration curve, the proper LII-voltage can be determined for the desired average gray-level. The algorithm was implemented and evaluated in thirty-two in-vivo DSA runs on rabbits. The proper LII voltage was selected in all cases with no failures. Using the fluoroscopic LII gain setting to determine the appropriate DSA setting can greatly improve the workflow in clinical evaluations of the MAF. NIH Grants R01-EB008425, R01-EB002873 and an equipment grant from Toshiba Medical Systems Corp. © 2012 American Association of Physicists in Medicine.
Externally Delivered Focused Ultrasound for Renal Denervation.
Neuzil, Petr; Ormiston, John; Brinton, Todd J; Starek, Zdenek; Esler, Murray; Dawood, Omar; Anderson, Thomas L; Gertner, Michael; Whitbourne, Rob; Schmieder, Roland E
2016-06-27
The aim of this study was to assess clinical safety and efficacy outcomes of renal denervation executed by an externally delivered, completely noninvasive focused therapeutic ultrasound device. Renal denervation has emerged as a potential treatment approach for resistant hypertension. Sixty-nine subjects received renal denervation with externally delivered focused ultrasound via the Kona Medical Surround Sound System. This approach was investigated across 3 consecutive studies to optimize targeting, tracking, and dosing. In the third study, treatments were performed in a completely noninvasive way using duplex ultrasound image guidance to target the therapy. Short- and long-term safety and efficacy were evaluated through use of clinical assessments, magnetic resonance imaging scans prior to and 3 and 24 weeks after renal denervation, and, in cases in which a targeting catheter was used to facilitate targeting, fluoroscopic angiography with contrast. All patients tolerated renal denervation using externally delivered focused ultrasound. Office blood pressure (BP) decreased by 24.6 ± 27.6/9.0 ± 15.0 mm Hg (from baseline BP of 180.0 ± 18.5/97.7 ± 13.7 mm Hg) in 69 patients after 6 months and 23.8 ± 24.1/10.3 ± 13.1 mm Hg in 64 patients with complete 1-year follow-up. The response rate (BP decrease >10 mm Hg) was 75% after 6 months and 77% after 1 year. The most common adverse event was post-treatment back pain, which was reported in 32 of 69 patients and resolved within 72 h in most cases. No intervention-related adverse events involving motor or sensory deficits were reported. Renal function was not altered, and vascular safety was established by magnetic resonance imaging (all patients), fluoroscopic angiography (n = 48), and optical coherence tomography (n = 5). Using externally delivered focused ultrasound and noninvasive duplex ultrasound, image-guided targeting was associated with substantial BP reduction without any major safety signals. Further randomized, sham-controlled trials will be needed to validate this unique approach. Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
MO-DE-BRA-04: Hands-On Fluoroscopy Safety Training with Real-Time Patient and Staff Dosimetry
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vanderhoek, M; Bevins, N
Purpose: Fluoroscopically guided interventions (FGI) are routinely performed across many different hospital departments. However, many involved staff members have minimal training regarding safe and optimal use of fluoroscopy systems. We developed and taught a hands-on fluoroscopy safety class incorporating real-time patient and staff dosimetry in order to promote safer and more optimal use of fluoroscopy during FGI. Methods: The hands-on fluoroscopy safety class is taught in an FGI suite, unique to each department. A patient equivalent phantom is set on the patient table with an ion chamber positioned at the x-ray beam entrance to the phantom. This provides a surrogatemore » measure of patient entrance dose. Multiple solid state dosimeters (RaySafe i2 dosimetry systemTM) are deployed at different distances from the phantom (0.1, 1, 3 meters), which provide surrogate measures of staff dose. Instructors direct participating clinical staff to operate the fluoroscopy system as they view live fluoroscopic images, patient entrance dose, and staff doses in real-time. During class, instructors work with clinical staff to investigate how patient entrance dose, staff doses, and image quality are affected by different parameters, including pulse rate, magnification, collimation, beam angulation, imaging mode, system geometry, distance, and shielding. Results: Real-time dose visualization enables clinical staff to directly see and learn how to optimize their use of their own fluoroscopy system to minimize patient and staff dose, yet maintain sufficient image quality for FGI. As a direct result of the class, multiple hospital departments have implemented changes to their imaging protocols, including reduction of the default fluoroscopy pulse rate and increased use of collimation and lower dose fluoroscopy modes. Conclusion: Hands-on fluoroscopy safety training substantially benefits from real-time patient and staff dosimetry incorporated into the class. Real-time dose display helps clinical staff visualize, internalize, and ultimately utilize the safety techniques learned during the training. RaySafe/Unfors/Fluke lent us a portable version of their RaySafe i2 Dosimetry System for 6 months.« less
Murphy, John C; Darragh, Karen; Walsh, Simon J; Hanratty, Colm G
2011-11-15
The RADPAD is a lead-free surgical drape containing bismuth and barium that has been demonstrated to reduce scatter radiation exposure to primary operators during fluoroscopic procedures. It is not known to what degree the RADPAD reduces radiation exposure in operators who perform highly complex percutaneous coronary intervention (PCI) requiring prolonged fluoroscopic screening times. Sixty consecutive patients due to undergo elective complex PCI involving rotational atherectomy, multivessel PCI, or chronic total occlusions were randomized in a 1:1 pattern to have their procedures performed with and without the RADPAD drape in situ. Dosimetry was performed on the left arm of the primary operator. There were 40 cases of chronic total occlusion, including 28 with contralateral injections; 15 cases involving rotational atherectomy; and 5 cases of multivessel PCI. There was no significant difference in screening times or dose-area products between the 2 patient groups. Primary operator radiation dose relative to screening time (RADPAD: slope = 1.44, R² = 0.25; no RADPAD: slope = 4.60, R² = 0.26; analysis of covariance F = 4.81, p = 0.032) and dose-area product (RADPAD: slope = 0.003, R² = 0.26; no RADPAD: slope = 0.011, R² = 0.52; analysis of covariance F = 12.54, p = 0.008) was significantly smaller in the RADPAD cohort compared to the no-RADPAD group. In conclusion, the RADPAD significantly reduces radiation exposure to primary operators during prolonged, complex PCI cases. Copyright © 2011 Elsevier Inc. All rights reserved.
SU-F-P-42: “To Navigate, Or Not to Navigate: HDR BT in Recurrent Spine Lesions”
DOE Office of Scientific and Technical Information (OSTI.GOV)
Voros, L; Cohen, G; Zaider, M
Purpose: We compare the accuracy of HDR catheter placement for paraspinal lesions using O-arm CBCT imaging combined with StealthStation navigation and traditional fluoroscopically guided catheter placement. Methods: CT and MRI scans were acquired pre-treatment to outline the lesions and design treatment plans (pre-plans) to meet dosimetric constrains. The pre-planned catheter trajectories were transferred into the StealthStation Navigation system prior to the surgery. The StealthStation is an infra red (IR) optical navigation system used for guidance of surgical instruments. An intraoperative CBCT scan (O-arm) was acquired with reference IR optical fiducials anchored onto the patient and registered with the preplan imagemore » study to guide surgical instruments in relation to the patients’ anatomy and to place the brachytherapy catheters along the pre-planned trajectories. The final treatment plan was generated based on a 2nd intraoperative CBCT scan reflecting achieved implant geometry. The 2nd CBCT was later registered with the initial CT scan to compare the preplanned dwell positions with actual dwell positions (catheter placements). Similar workflow was used in placement of 8 catheters (1 patient) without navigation, but under fluoroscopy guidance in an interventional radiology suite. Results: A total of 18 catheters (3 patients) were placed using navigation assisted surgery. Average displacement of 0.66 cm (STD=0.37cm) was observed between the pre-plan source positions and actual source positions in the 3 dimensional space. This translates into an average 0.38 cm positioning error in one direction including registration errors, digitization errors, and the surgeons ability to follow the planned trajectory. In comparison, average displacement of non-navigated catheters was 0.50 cm (STD=0.22cm). Conclusion: Spinal lesion HDR brachytherapy planning is a difficult task. Catheter placement has a direct impact on target coverage and dose to critical structures. While limited to a handful of patients, our experience shows navigation and fluoroscopy guided placement yield similar results.« less
Kwon, Won Kyoung; Kim, Ah Na; Lee, Pil Moo; Park, Cheol Hwan; Kim, Jae Hun
2016-01-01
Background. Caudal epidural steroid injections (CESIs) are an effective treatment for pain. If the injection spreads in a specific pattern depending on the needle position or bevel direction, it would be possible to inject the agent into a specific and desired area. Objectives. We conducted a prospective randomized trial to determine if the needle position and bevel direction have any effect on the epidural spreading pattern in CESI. Methods. Demographic data of the patient were collected. During CESI, the needle position (middle or lateral) and direction (ventral or dorsal) were randomly allocated. Following fluoroscope-guided injection of 4 mL contrast media and 10 mL of injectates, the epidural spreading patterns (ventral or dorsal, bilateral or lateral) were imaged. Results. In the 210 CESIs performed, the needle tip position and bevel direction did not influence the epidural spreading patterns at L4-5 and L5-S1 disc levels. A history of Lumbar spine surgery was associated with a significantly limited spread to each disc level. A midline needle tip position was more effective than the lateral position in spreading to the distant disc levels. Conclusions. Neither the needle tip position nor the bevel direction affected the epidural drug spreading pattern during CESI. PMID:27445609
Heran, Manraj K S; Baird, Robert; Blair, Geoffrey K; Skarsgard, Erik D
2008-05-01
Nonsurgical treatment of recalcitrant pediatric esophageal strictures is challenging. The chemotherapy drug mitomycin-C, which reduces collagen synthesis and scar formation, shows anecdotal promise in the topical treatment of these strictures. Mitomycin-C is cytotoxic, and a safe endoluminal delivery system that avoids inadvertent application to adjacent mucosa has not yet been described. We have treated 2 patients with a combined endoscopic/fluoroscopic technique that ensures protected delivery of a mitomycin-soaked pledget directly to the targeted site. Following pneumatic balloon dilation of the stricture under fluoroscopy, flexible esophagoscopy is performed to the disrupted stricture. Through the gastrostomy tract, a 12F to 16F semirigid sheath is introduced over a guide wire and passed retrograde up the esophagus to the stricture. A grasping forceps introduced through the instrument channel of the esophagoscope is advanced through the sheath and grasps a mitomycin-C-soaked pledget. The pledget is drawn back through the sheath up to the stricture where timed, serial radial applications to the stricture are performed without any contamination of the rest of the esophagus or stomach. We describe a novel technique of endoluminal delivery and focused application of mitomycin-C to an esophageal stricture that avoids inadvertent topical application to adjacent mucosa.
[Arthroscopy-guided fracture management. Ankle joint and calcaneus].
Schoepp, C; Rixen, D
2013-04-01
Arthroscopic fracture management of the ankle and calcaneus requires a differentiated approach. The aim is to minimize surgical soft tissue damage and to visualize anatomical fracture reduction arthroscopically. Moreover, additional cartilage damage can be detected and treated. The arthroscopic approach is limited by deep impressions of the joint surface needing cancellous bone grafting, by multiple fracture lines on the articular side and by high-grade soft tissue damage. An alternative to the minimally invasive arthroscopic approach is open arthroscopic reduction in conventional osteosynthesis. This facilitates correct assessment of surgical reduction of complex calcaneal fractures, otherwise remaining non-anatomical reduction might not be fluoroscopically detected during surgery.
Radiation Exposure in Transjugular Intrahepatic Portosystemic Shunt Creation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Miraglia, Roberto, E-mail: rmiraglia@ismett.edu; Maruzzelli, Luigi, E-mail: lmaruzzelli@ismett.edu; Cortis, Kelvin, E-mail: kelvincortis@ismett.edu
2016-02-15
PurposeTransjugular intrahepatic portosystemic shunt (TIPS) creation is considered as being one of the most complex procedures in abdominal interventional radiology. Our aim was twofold: quantification of TIPS-related patient radiation exposure in our center and identification of factors leading to reduced radiation exposure.Materials and methodsThree hundred and forty seven consecutive patients underwent TIPS in our center between 2007 and 2014. Three main procedure categories were identified: Group I (n = 88)—fluoroscopic-guided portal vein targeting, procedure done in an image intensifier-based angiographic system (IIDS); Group II (n = 48)—ultrasound-guided portal vein puncture, procedure done in an IIDS; and Group III (n = 211)—ultrasound-guided portal vein puncture, procedure donemore » in a flat panel detector-based system (FPDS). Radiation exposure (dose-area product [DAP], in Gy cm{sup 2} and fluoroscopy time [FT] in minutes) was retrospectively analyzed.ResultsDAP was significantly higher in Group I (mean ± SD 360 ± 298; median 287; 75th percentile 389 Gy cm{sup 2}) as compared to Group II (217 ± 130; 178; 276 Gy cm{sup 2}; p = 0.002) and Group III (129 ± 117; 70; 150 Gy cm{sup 2}p < 0.001). The difference in DAP between Groups II and III was also significant (p < 0.001). Group I had significantly longer FT (25.78 ± 13.52 min) as compared to Group II (20.45 ± 10.87 min; p = 0.02) and Group III (19.76 ± 13.34; p < 0.001). FT was not significantly different between Groups II and III (p = 0.73).ConclusionsReal-time ultrasound-guided targeting of the portal venous system during TIPS creation results in a significantly lower radiation exposure and reduced FT. Further reduction in radiation exposure can be achieved through the use of modern angiographic units with FPDS.« less
Combination of CT scanning and fluoroscopy imaging on a flat-panel CT scanner
NASA Astrophysics Data System (ADS)
Grasruck, M.; Gupta, R.; Reichardt, B.; Suess, Ch.; Schmidt, B.; Stierstorfer, K.; Popescu, S.; Brady, T.; Flohr, T.
2006-03-01
We developed and evaluated a prototype flat-panel detector based Volume CT (fpVCT) scanner. The fpVCT scanner consists of a Varian 4030CB a-Si flat-panel detector mounted in a multi slice CT-gantry (Siemens Medical Solutions). It provides a 25 cm field of view with 18 cm z-coverage at the isocenter. In addition to the standard tomographic scanning, fpVCT allows two new scan modes: (1) fluoroscopic imaging from any arbitrary rotation angle, and (2) continuous, time-resolved tomographic scanning of a dynamically changing viewing volume. Fluoroscopic imaging is feasible by modifying the standard CT gantry so that the imaging chain can be oriented along any user-selected rotation angle. Scanning with a stationary gantry, after it has been oriented, is equivalent to a conventional fluoroscopic examination. This scan mode enables combined use of high-resolution tomography and real-time fluoroscopy with a clinically usable field of view in the z direction. The second scan mode allows continuous observation of a timeevolving process such as perfusion. The gantry can be continuously rotated for up to 80 sec, with the rotation time ranging from 3 to 20 sec, to gather projection images of a dynamic process. The projection data, that provides a temporal log of the viewing volume, is then converted into multiple image stacks that capture the temporal evolution of a dynamic process. Studies using phantoms, ex vivo specimens, and live animals have confirmed that these new scanning modes are clinically usable and offer a unique view of the anatomy and physiology that heretofore has not been feasible using static CT scanning. At the current level of image quality and temporal resolution, several clinical applications such a dynamic angiography, tumor enhancement pattern and vascularity studies, organ perfusion, and interventional applications are in reach.
TU-D-209-03: Alignment of the Patient Graphic Model Using Fluoroscopic Images for Skin Dose Mapping
DOE Office of Scientific and Technical Information (OSTI.GOV)
Oines, A; Oines, A; Kilian-Meneghin, J
2016-06-15
Purpose: The Dose Tracking System (DTS) was developed to provide realtime feedback of skin dose and dose rate during interventional fluoroscopic procedures. A color map on a 3D graphic of the patient represents the cumulative dose distribution on the skin. Automated image correlation algorithms are described which use the fluoroscopic procedure images to align and scale the patient graphic for more accurate dose mapping. Methods: Currently, the DTS employs manual patient graphic selection and alignment. To improve the accuracy of dose mapping and automate the software, various methods are explored to extract information about the beam location and patient morphologymore » from the procedure images. To match patient anatomy with a reference projection image, preprocessing is first used, including edge enhancement, edge detection, and contour detection. Template matching algorithms from OpenCV are then employed to find the location of the beam. Once a match is found, the reference graphic is scaled and rotated to fit the patient, using image registration correlation functions in Matlab. The algorithm runs correlation functions for all points and maps all correlation confidences to a surface map. The highest point of correlation is used for alignment and scaling. The transformation data is saved for later model scaling. Results: Anatomic recognition is used to find matching features between model and image and image registration correlation provides for alignment and scaling at any rotation angle with less than onesecond runtime, and at noise levels in excess of 150% of those found in normal procedures. Conclusion: The algorithm provides the necessary scaling and alignment tools to improve the accuracy of dose distribution mapping on the patient graphic with the DTS. Partial support from NIH Grant R01-EB002873 and Toshiba Medical Systems Corp.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Slattery, Michael M.; Goh, Gerard S.; Power, Sarah
PurposeTo prospectively compare the procedural time and complication rates of ultrasound-guided and fluoroscopy-assisted antegrade common femoral artery (CFA) puncture techniques.Materials and MethodsHundred consecutive patients, undergoing a vascular procedure for which an antegrade approach was deemed necessary/desirable, were randomly assigned to undergo either ultrasound-guided or fluoroscopy-assisted CFA puncture. Time taken from administration of local anaesthetic to vascular sheath insertion in the superficial femoral artery (SFA), patients’ age, body mass index (BMI), fluoroscopy radiation dose, haemostasis method and immediate complications were recorded. Mean and median values were calculated and statistically analysed with unpaired t tests.ResultsSixty-nine male and 31 female patients underwent antegrademore » puncture (mean age 66.7 years). The mean BMI was 25.7 for the ultrasound-guided (n = 53) and 25.3 for the fluoroscopy-assisted (n = 47) groups. The mean time taken for the ultrasound-guided puncture was 7 min 46 s and for the fluoroscopy-assisted technique was 9 min 41 s (p = 0.021). Mean fluoroscopy dose area product in the fluoroscopy group was 199 cGy cm{sup 2}. Complications included two groin haematomas in the ultrasound-guided group and two retroperitoneal haematomas and one direct SFA puncture in the fluoroscopy-assisted group.ConclusionUltrasound-guided technique is faster and safer for antegrade CFA puncture when compared to the fluoroscopic-assisted technique alone.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nose, Takayuki, E-mail: nose-takayuki@nms.ac.jp; Chatani, Masashi; Otani, Yuki
Purpose: High-dose-rate (HDR) brachytherapy misdeliveries can occur at any institution, and they can cause disastrous results. Even a patient's death has been reported. Misdeliveries could be avoided with real-time verification methods. In 1996, we developed a modified C-arm fluoroscopic verification of an HDR Iridium 192 source position prevent these misdeliveries. This method provided excellent image quality sufficient to detect errors, and it has been in clinical use at our institutions for 20 years. The purpose of the current study is to introduce the mechanisms and validity of our straightforward C-arm fluoroscopic verification method. Methods and Materials: Conventional X-ray fluoroscopic images aremore » degraded by spurious signals and quantum noise from Iridium 192 photons, which make source verification impractical. To improve image quality, we quadrupled the C-arm fluoroscopic X-ray dose per pulse. The pulse rate was reduced by a factor of 4 to keep the average exposure compliant with Japanese medical regulations. The images were then displayed with quarter-frame rates. Results: Sufficient quality was obtained to enable observation of the source position relative to both the applicators and the anatomy. With this method, 2 errors were detected among 2031 treatment sessions for 370 patients within a 6-year period. Conclusions: With the use of a modified C-arm fluoroscopic verification method, treatment errors that were otherwise overlooked were detected in real time. This method should be given consideration for widespread use.« less
Nose, Takayuki; Chatani, Masashi; Otani, Yuki; Teshima, Teruki; Kumita, Shinichirou
2017-03-15
High-dose-rate (HDR) brachytherapy misdeliveries can occur at any institution, and they can cause disastrous results. Even a patient's death has been reported. Misdeliveries could be avoided with real-time verification methods. In 1996, we developed a modified C-arm fluoroscopic verification of an HDR Iridium 192 source position prevent these misdeliveries. This method provided excellent image quality sufficient to detect errors, and it has been in clinical use at our institutions for 20 years. The purpose of the current study is to introduce the mechanisms and validity of our straightforward C-arm fluoroscopic verification method. Conventional X-ray fluoroscopic images are degraded by spurious signals and quantum noise from Iridium 192 photons, which make source verification impractical. To improve image quality, we quadrupled the C-arm fluoroscopic X-ray dose per pulse. The pulse rate was reduced by a factor of 4 to keep the average exposure compliant with Japanese medical regulations. The images were then displayed with quarter-frame rates. Sufficient quality was obtained to enable observation of the source position relative to both the applicators and the anatomy. With this method, 2 errors were detected among 2031 treatment sessions for 370 patients within a 6-year period. With the use of a modified C-arm fluoroscopic verification method, treatment errors that were otherwise overlooked were detected in real time. This method should be given consideration for widespread use. Copyright © 2016 Elsevier Inc. All rights reserved.
Navigation within the heart and vessels in clinical practice.
Beyar, Rafael
2010-02-01
The field of interventional cardiology has developed at an unprecedented pace on account of the visual and imaging power provided by constantly improving biomedical technologies. Transcatheter-based technology is now routinely used for coronary revascularization and noncoronary interventions using balloon angioplasty, stents, and many other devices. In the early days of interventional practice, the operating physician had to manually navigate catheters and devices under fluoroscopic imaging and was exposed to radiation, with its comcomitant necessity for wearing heavy lead aprons for protection. Until recently, very little has changed in the way procedures have been carried out in the catheterization laboratory. The technological capacity to remotely manipulate devices, using robotic arms and computational tools, has been developed for surgery and other medical procedures. This has brought to practice the powerful combination of the abilities afforded by imaging, navigational tools, and remote control manipulation. This review covers recent developments in navigational tools for catheter positioning, electromagnetic mapping, magnetic resonance imaging (MRI)-based cardiac electrophysiological interventions, and navigation tools through coronary arteries.
Sheen, Jae Jon; Jiang, Yuan Yuan; Kim, Young Eun; Maeng, Jun Young; Kim, Tae-Il; Lee, Deok Hee
2018-03-23
Onyx embolization is a treatment for brain arteriovenous malformations (AVMs). However, multistage embolization usually involves the presence of radiodense Onyx cast from the previous sessions, which may influence the fluoroscopic radiation dose. We compared the fluoroscopic dose between the initial and final embolization sessions. From January 2014 to September 2016, 18 patients underwent multistage Onyx embolization (more than twice) for brain AVMs. The total fluoroscopic duration (minutes), dose-area product (DAP, Gy×cm 2 ), and cumulative air kerma (CAK, mGy) of both the frontal and lateral planes were obtained. We compared the frontal and lateral fluoroscopic dose rates (dose/time) of the final embolization session with those of the initial session. The relationship between the injected Onyx volume and radiation dose was tested. The initial and final procedures on the frontal plane showed significantly different fluoroscopic dose rates (DAP: initial 0.668 Gy×cm 2 /min, final 0.848 Gy×cm 2 /min, P=0.02; CAK: initial 12.7 mGy/min, final 23.1 mGy/min, P=0.007). Those on the lateral plane also showed a similar pattern (DAP: initial 0.365 Gy×cm 2 /min, final 0.519 Gy×cm 2 /min, P=0.03; CAK: initial 6.2 mGy/min, final 12.9 mGy/min, P=0.01). The correlation between the cumulative Onyx volume (vials) and radiation dose ratio of both planes showed an increasing trend (rho 0.4325-0.7053; P=0.0011-0.0730). Owing to the automatic exposure control function during fluoroscopy, successive Onyx embolization procedures increase the fluoroscopic radiation dose in multistage brain AVM embolization because of the presence of radiodense Onyx mass. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
NASA Astrophysics Data System (ADS)
Li, Ruijiang; Lewis, John H.; Cerviño, Laura I.; Jiang, Steve B.
2009-10-01
A major difficulty in conformal lung cancer radiotherapy is respiratory organ motion, which may cause clinically significant targeting errors. Respiratory-gated radiotherapy allows for more precise delivery of prescribed radiation dose to the tumor, while minimizing normal tissue complications. Gating based on external surrogates is limited by its lack of accuracy, while gating based on implanted fiducial markers is limited primarily by the risk of pneumothorax due to marker implantation. Techniques for fluoroscopic gating without implanted fiducial markers (markerless gating) have been developed. These techniques usually require a training fluoroscopic image dataset with marked tumor positions in the images, which limits their clinical implementation. To remove this requirement, this study presents a markerless fluoroscopic gating algorithm based on 4DCT templates. To generate gating signals, we explored the application of three similarity measures or scores between fluoroscopic images and the reference 4DCT template: un-normalized cross-correlation (CC), normalized cross-correlation (NCC) and normalized mutual information (NMI), as well as average intensity (AI) of the region of interest (ROI) in the fluoroscopic images. Performance was evaluated using fluoroscopic and 4DCT data from three lung cancer patients. On average, gating based on CC achieves the highest treatment accuracy given the same efficiency, with a high target coverage (average between 91.9% and 98.6%) for a wide range of nominal duty cycles (20-50%). AI works well for two patients out of three, but failed for the third patient due to interference from the heart. Gating based on NCC and NMI usually failed below 50% nominal duty cycle. Based on this preliminary study with three patients, we found that the proposed CC-based gating algorithm can generate accurate and robust gating signals when using 4DCT reference template. However, this observation is based on results obtained from a very limited dataset, and further investigation on a larger patient population has to be done before its clinical implementation.
3D fluoroscopic image estimation using patient-specific 4DCBCT-based motion models
Dhou, Salam; Hurwitz, Martina; Mishra, Pankaj; Cai, Weixing; Rottmann, Joerg; Li, Ruijiang; Williams, Christopher; Wagar, Matthew; Berbeco, Ross; Ionascu, Dan; Lewis, John H.
2015-01-01
3D fluoroscopic images represent volumetric patient anatomy during treatment with high spatial and temporal resolution. 3D fluoroscopic images estimated using motion models built using 4DCT images, taken days or weeks prior to treatment, do not reliably represent patient anatomy during treatment. In this study we develop and perform initial evaluation of techniques to develop patient-specific motion models from 4D cone-beam CT (4DCBCT) images, taken immediately before treatment, and use these models to estimate 3D fluoroscopic images based on 2D kV projections captured during treatment. We evaluate the accuracy of 3D fluoroscopic images by comparing to ground truth digital and physical phantom images. The performance of 4DCBCT- and 4DCT- based motion models are compared in simulated clinical situations representing tumor baseline shift or initial patient positioning errors. The results of this study demonstrate the ability for 4DCBCT imaging to generate motion models that can account for changes that cannot be accounted for with 4DCT-based motion models. When simulating tumor baseline shift and patient positioning errors of up to 5 mm, the average tumor localization error and the 95th percentile error in six datasets were 1.20 and 2.2 mm, respectively, for 4DCBCT-based motion models. 4DCT-based motion models applied to the same six datasets resulted in average tumor localization error and the 95th percentile error of 4.18 and 5.4 mm, respectively. Analysis of voxel-wise intensity differences was also conducted for all experiments. In summary, this study demonstrates the feasibility of 4DCBCT-based 3D fluoroscopic image generation in digital and physical phantoms, and shows the potential advantage of 4DCBCT-based 3D fluoroscopic image estimation when there are changes in anatomy between the time of 4DCT imaging and the time of treatment delivery. PMID:25905722
Computerized tomography using video recorded fluoroscopic images
NASA Technical Reports Server (NTRS)
Kak, A. C.; Jakowatz, C. V., Jr.; Baily, N. A.; Keller, R. A.
1975-01-01
A computerized tomographic imaging system is examined which employs video-recorded fluoroscopic images as input data. By hooking the video recorder to a digital computer through a suitable interface, such a system permits very rapid construction of tomograms.
Le Graverand, M-P H; Mazzuca, S; Lassere, M; Guermazi, A; Pickering, E; Brandt, K; Peterfy, C; Cline, G; Nevitt, M; Woodworth, T; Conaghan, P; Vignon, E
2006-01-01
Recent studies using various standardized radiographic acquisition techniques have demonstrated the necessity of reproducible radioanatomic alignment of the knee to assure precise measurements of medial tibiofemoral joint space width (JSW). The objective of the present study was to characterize the longitudinal performance of several acquisition techniques with respect to long-term reproducibility of positioning of the knee, and the impact of changes in positioning on the rate and variability of joint space narrowing (JSN). Eighty subjects were randomly selected from each of three cohorts followed in recent studies of the radiographic progression of knee osteoarthritis (OA): the Health ABC study (paired fixed-flexion [FF] radiographs taken at a 36-month interval); the Glucosamine Arthritis Intervention Trial (GAIT) (paired metatarsophalangeal [MTP] radiographs obtained at a 12-month interval), and a randomized clinical trial of doxycycline (fluoroscopically assisted semiflexed anteroposterior (AP) radiographs taken at a 16-month interval). Manual measurements were obtained from each radiograph to represent markers of radioanatomic positioning of the knee (alignment of the medial tibial plateau and X-ray beam, knee rotation, femorotibial angle) and to evaluate minimum JSW (mJSW) in the medial tibiofemoral compartment. The effects on the mean annualized rate of JSN and on the variability of that rate of highly reproduced vs variable positioning of the knee in serial radiographs were evaluated. Parallel or near-parallel alignment was achieved significantly more frequently with the fluoroscopically guided positioning used in the semiflexed AP protocol than with either the non-fluoroscopic FF or MTP protocol (68% vs 14% for both FF and MTP protocols when measured at the midpoint of the medial compartment; 75% vs 26% and 34% for the FF and MTP protocols, respectively, when measured at the site of mJSW; P<0.001 for each). Knee rotation was reproduced more frequently in semiflexed AP radiographs than in FF radiographs (66% vs 45%, P<0.01). In contrast, the FF technique yielded a greater proportion of paired radiographs in which the femorotibial angle was accurately reproduced than the semiflexed AP or MTP protocol (78% vs 59% and 56%, respectively, P<0.01 for each). Notably, only paired radiographs with parallel or near-parallel alignment exhibited a mean rate of JSN (+/-SD) in the OA knee that was more rapid and less variable than that measured in all knees (0.186+/-0.274 mm/year, standardized response to mean [SRM]=0.68 vs 0.128+/-0.291 mm/year, SRM=0.44). This study confirms the importance of parallel radioanatomic alignment of the anterior and posterior margins of the medial tibial plateau in detecting JSN in subjects with knee OA. The use of radiographic methods that assure parallel alignment during serial X-ray examinations will permit the design of more efficient studies of biomarkers of OA progression and of structure modification in knee OA.
Tricuspid Clip: Step-by-Step and Clinical Data.
Tang, Gilbert H L
2018-01-01
Symptomatic severe tricuspid regurgitation (TR), if untreated, carries a dismal prognosis. These patients are at very high risk for surgical repair or replacement and transcatheter options to treat TR are emerging. More than 300 transcatheter tricuspid repairs with the MitraClip system have been performed worldwide with promising results. The TriClip system, with the MitraClip NT delivered via a dedicated tricuspid steerable guide catheter, is currently under investigation. This article describes the step-by-step technique on using the MitraClip system to perform transcatheter tricuspid repair using echocardiographic and fluoroscopic guidance. The latest data on worldwide experience with tricuspid clipping are also discussed. Copyright © 2017 Elsevier Inc. All rights reserved.
Hybrid treatment of common carotid artery occlusion with ring-stripper endarterectomy plus stenting.
Pintér, László; Cagiannos, Catherine; Bakoyiannis, Chris N; Kolvenbach, Ralf
2007-07-01
Symptomatic occlusion of the common carotid artery with preserved circulation in the internal carotid artery is an uncommon occurrence. We describe a hybrid technique whereby a patient was treated with eversion carotid bifurcation endarterectomy, fluoroscopically guided retrograde ring-stripper common carotid endarterectomy, and stenting of residual stenosis in the disobliterated artery. Successful recanalization was achieved without adverse anatomic or neurologic sequelae. The patient remains asymptomatic with a radiographically patent reconstruction at 1 year. This combination of endovascular and open surgery enables the surgeon to address long occlusions of the common carotid arteries with control of the distal and proximal endarterectomy margins and obviates the need for general anesthesia or sternotomy.
Radiology-guided forceps biopsy and airway stenting in severe airway stenosis.
Li, Zong Ming; Wu, Gang; Han, Xin Wei; Ren, Ke Wei; Zhu, Ming
2014-01-01
We aimed to determine the feasibility, safety, and effectiveness of radiology-guided forceps biopsy and airway stenting in patients with severe airway stenosis. This study involved 28 patients with severe airway stenosis who underwent forceps biopsy between October 2006 and September 2011. Chest multislice computed tomography was used to determine the location and extent of stenosis. Sixteen patients had tracheal stenosis, two patients had stenosis of the tracheal carina, six patients had stenosis of the left main bronchus, and four patients had stenosis of the right main bronchus. Forceps biopsy and stenting of the stenosed area were performed under fluoroscopic guidance in digital subtraction angiography and the biopsy specimens were analyzed histopathologically. We contacted the patients via phone call and utilized a standardized questionnaire to determine their medical condition during a postoperative three-month follow-up. The technical success rate of radiology-guided forceps biopsy was 100%. Biopsy specimens were obtained in all patients. Dyspnea was relieved immediately after stent placement. No serious complications, such as tracheal hemorrhage or perforation, mediastinal emphysema, or asphyxia, occurred. Radiology-guided forceps biopsy and airway stenting can be used for the emergency treatment of severe airway stenosis. This method appears to be safe and effective, and it may be an alternative therapeutic option in patients who cannot tolerate fiberoptic bronchoscopy.
Predictors of Interventional Success of Antegrade PCI for CTO.
Luo, Chun; Huang, Meiping; Li, Jinglei; Liang, Changhong; Zhang, Qun; Liu, Hui; Liu, Zaiyi; Qu, Yanji; Jiang, Jun; Zhuang, Jian
2015-07-01
This study aimed to identify significant lesion features of chronic total occlusions (CTOs) that predict failure of antegrade (A) percutaneous coronary intervention (PCI) using pre-procedure coronary computed tomography angiography (CTA) combined with conventional coronary angiography (CCA). The current predictors of successful A-PCI in the setting of CTOs are uncertain. Such knowledge might prompt early performance of a retrograde (R)-PCI approach if predictors of A-PCI failure are present. Consecutive patients confirmed to have at least 1 CTO of native coronary arteries underwent coronary CTA- and CCA-guided PCI in which computed tomography and fluoroscopic images were placed side by side before or during PCI. The study included 103 patients with 108 CTOs; 80 lesions were successfully treated with A-PCI and 28 lesions failed this approach, for an A-PCI success rate of 74%. A total of 15 of 28 failed cases underwent attempted R-PCI. Only 1 case also failed R-PCI; thus, the total PCI success rate was 87%. By multivariable analysis, the factors significantly predictive of failed A-PCI included negative remodeling (odds ratio [OR]: 137.82) and lesion length >31.89 mm on coronary CTA (OR: 7.04), and ostial or bifurcation lesions on CCA (OR: 8.02). R-PCI was successful in 14 of 15 patients (93.3%), in whom good appearance of the occluded distal segment and well-developed collateral vessels were present. Morphologic predictors of failed A-PCI on the basis of pre-procedure coronary CTA and CCA imaging may be identified, which may assist in determining which patients with CTO lesions would benefit from an early R-PCI strategy. Copyright © 2015 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Medici, S; Pitzschke, A; Cherbuin, N; Boldini, M; Sans-Merce, M; Damet, J
2017-11-01
The purpose of this work was to estimate the eye lens radiation exposure of the medical staff during interventional urology procedures. The measurements were carried out for six medical staff members performing 33 fluoroscopically-guided procedures. All procedures were performed with the X-ray tube positioned over the couch. The dose equivalents (H p (0.07)) were measured at the eye level using optically stimulated luminescent (OSL) dosimeters and at the chest level with OSL dosimeters placed over the protective apron. The ratio of the dose measured close to the eye lens and on the chest was determined. The annual eye lens dose was estimated based on the workload in the service. For the physician and the instrumentalist nurse, the eye to chest dose ratios were 0.9±0.4 and 2.6±1.6 (k = 2), respectively. The average doses per procedure received by the eye lens were 78±24 μSv and 38±18 μSv, respectively. The eye lens dose per DAP was 8.4±17.5 μSv/(Gy·cm 2 ) for the physician and 4.1±8.7 μSv/(Gy·cm 2 ) for the instrumentalist nurse. The results indicate that the eye lens to chest dose ratio greatly varies according to the staff function and that the dose equivalent measured by the personal dosimeter worn on the chest may underestimate the eye lens dose of some medical staff members. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Moirano, J
Purpose: An accurate dose estimate is necessary for effective patient management after a fetal exposure. In the case of a high-dose exposure, it is critical to use all resources available in order to make the most accurate assessment of the fetal dose. This work will demonstrate a methodology for accurate fetal dose estimation using tools that have recently become available in many clinics, and show examples of best practices for collecting data and performing the fetal dose calculation. Methods: A fetal dose estimate calculation was performed using modern data collection tools to determine parameters for the calculation. The reference pointmore » air kerma as displayed by the fluoroscopic system was checked for accuracy. A cumulative dose incidence map and DICOM header mining were used to determine the displayed reference point air kerma. Corrections for attenuation caused by the patient table and pad were measured and applied in order to determine the peak skin dose. The position and depth of the fetus was determined by ultrasound imaging and consultation with a radiologist. The data collected was used to determine a normalized uterus dose from Monte Carlo simulation data. Fetal dose values from this process were compared to other accepted calculation methods. Results: An accurate high-dose fetal dose estimate was made. Comparison to accepted legacy methods were were within 35% of estimated values. Conclusion: Modern data collection and reporting methods ease the process for estimation of fetal dose from interventional fluoroscopy exposures. Many aspects of the calculation can now be quantified rather than estimated, which should allow for a more accurate estimation of fetal dose.« less
Kamara, Eli; Robinson, Jonathon; Bas, Marcel A; Rodriguez, Jose A; Hepinstall, Matthew S
2017-01-01
Acetabulum positioning affects dislocation rates, component impingement, bearing surface wear rates, and need for revision surgery. Novel techniques purport to improve the accuracy and precision of acetabular component position, but may have a significant learning curve. Our aim was to assess whether adopting robotic or fluoroscopic techniques improve acetabulum positioning compared to manual total hip arthroplasty (THA) during the learning curve. Three types of THAs were compared in this retrospective cohort: (1) the first 100 fluoroscopically guided direct anterior THAs (fluoroscopic anterior [FA]) done by a surgeon learning the anterior approach, (2) the first 100 robotic-assisted posterior THAs done by a surgeon learning robotic-assisted surgery (robotic posterior [RP]), and (3) the last 100 manual posterior (MP) THAs done by each surgeon (200 THAs) before adoption of novel techniques. Component position was measured on plain radiographs. Radiographic measurements were taken by 2 blinded observers. The percentage of hips within the surgeons' "target zone" (inclination, 30°-50°; anteversion, 10°-30°) was calculated, along with the percentage within the "safe zone" of Lewinnek (inclination, 30°-50°; anteversion, 5°-25°) and Callanan (inclination, 30°-45°; anteversion, 5°-25°). Relative risk (RR) and absolute risk reduction (ARR) were calculated. Variances (square of the standard deviations) were used to describe the variability of cup position. Seventy-six percentage of MP THAs were within the surgeons' target zone compared with 84% of FA THAs and 97% of RP THAs. This difference was statistically significant, associated with a RR reduction of 87% (RR, 0.13 [0.04-0.40]; P < .01; ARR, 21%; number needed to treat, 5) for RP compared to MP THAs. Compared to FA THAs, RP THAs were associated with a RR reduction of 81% (RR, 0.19 [0.06-0.62]; P < .01; ARR, 13%; number needed to treat, 8). Variances were lower for acetabulum inclination and anteversion in RP THAs (14.0 and 19.5) as compared to the MP (37.5 and 56.3) and FA (24.5 and 54.6) groups. These differences were statistically significant (P < .01). Adoption of robotic techniques delivers significant and immediate improvement in the precision of acetabular component positioning during the learning curve. While fluoroscopy has been shown to be beneficial with experience, a learning curve exists before precision improves significantly. Copyright © 2016 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Iovea, M.; Creed, J.; Perin, E.; Neagu, M.; Mateiasi, G.
2009-02-01
The aim of this study was to conduct a preliminary check of a new method for measuring the 3D catheter position based on only one X-Ray view (image) and a simple pre-calibration procedure for catheters that could be equipped with high-opacity equal-spaced markers. The application chosen for this experiment is the targeted delivery of cell based therapeutic via a transendocardial retrograde approach into the left ventricle. This approach has shown promising therapeutic retention data when injected directly into the myocardial tissue, but lacks in the ability of the user to confidently manipulate the catheter within the left ventricle cavity space under traditional fluoroscopic guidance using a needle based catheter. The need for a new technique arose from the potential for increased safety and therapeutic efficacy by improving the targeting of the agent. The new technique, destined for Image guided catheter navigation systems for cardiac interventions, is based on a measurement of the marker's size and distance between them and followed by a comparison with the referenced catheter position. Preliminary experiments made with a simple phantom are presented, emphasizing the ability of the new technique in measuring the markers and the catheter tip 3D position. An overall maximum error in positioning markers and catheter tip below 12% has been obtained, yielding a promising result for continuing the future work of improving the algorithm accuracy.
On-the-fly augmented reality for orthopedic surgery using a multimodal fiducial.
Andress, Sebastian; Johnson, Alex; Unberath, Mathias; Winkler, Alexander Felix; Yu, Kevin; Fotouhi, Javad; Weidert, Simon; Osgood, Greg; Navab, Nassir
2018-04-01
Fluoroscopic x-ray guidance is a cornerstone for percutaneous orthopedic surgical procedures. However, two-dimensional (2-D) observations of the three-dimensional (3-D) anatomy suffer from the effects of projective simplification. Consequently, many x-ray images from various orientations need to be acquired for the surgeon to accurately assess the spatial relations between the patient's anatomy and the surgical tools. We present an on-the-fly surgical support system that provides guidance using augmented reality and can be used in quasiunprepared operating rooms. The proposed system builds upon a multimodality marker and simultaneous localization and mapping technique to cocalibrate an optical see-through head mounted display to a C-arm fluoroscopy system. Then, annotations on the 2-D x-ray images can be rendered as virtual objects in 3-D providing surgical guidance. We quantitatively evaluate the components of the proposed system and, finally, design a feasibility study on a semianthropomorphic phantom. The accuracy of our system was comparable to the traditional image-guided technique while substantially reducing the number of acquired x-ray images as well as procedure time. Our promising results encourage further research on the interaction between virtual and real objects that we believe will directly benefit the proposed method. Further, we would like to explore the capabilities of our on-the-fly augmented reality support system in a larger study directed toward common orthopedic interventions.
New Jersey's Thomas Edison and the fluoroscope.
Tselos, G D
1995-11-01
Thomas Edison played a major role in the development of early x-ray technology in 1896, notably increasing tube power and reliability and making the fluoroscope a practical instrument. Eventually, Edison would move x-ray technology from the laboratory to the marketplace.
Weksler, Natan; Velan, Gad J; Semionov, Michael; Gurevitch, Boris; Klein, Moti; Rozentsveig, Vsevolod; Rudich, Tzvia
2007-12-01
It is a common practice to the link low back pain with protruding disc even when neurological signs are absent. Because pain caused by sacroiliac joint dysfunction can mimic discogenic or radicular low back pain, we assumed that the diagnosis of sacroiliac joint dysfunction is frequently overlooked. To assess the incidence of sacroiliac joint dysfunction in patients with low back pain and positive disc findings on CT scan or MRI, but without claudication or objective neurological deficits. Fifty patients with low back pain and disc herniation, without claudication or neurological abnormalities such as decreased motor strength, sensory alterations or sphincter incontinence and with positive pain provocation tests for sacroiliac joint dysfunction were submitted to fluoroscopic diagnostic sacroiliac joint infiltration. The mean baseline VAS pain score was 7.8 +/- 1.77 (range 5-10). Thirty minutes after infiltration, the mean VAS score was 1.3 +/- 1.76 (median 0.000E+00 with an average deviation from median = 1.30) (P = 0.0002). Forty-six patients had a VAS score ranging from 0 to 3, 8 weeks after the fluoroscopic guided infiltration. There were no serious complications after treatment. An unanticipated motor block that required hospitalization was seen in four patients, lasting from 12 to 36 h. Sacroiliac joint dysfunction should be considered strongly in the differential diagnosis of low back pain in this group of patients.
Guided percutaneous fine-needle aspiration biopsy of the liver
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ho, C.S.; McLoughlin, M.J.; Tao, L.C.
1981-04-01
Forty patients with suspected malignant disease of the liver underwent percutaneous fine-needle aspiration biopsy with radioisotope scintigraphic and fluoroscopic guidance. The needle was aimed at focal defects identified on the liver scan and several passes were made. When the scan was diffusely abnormal, the liver was widely sampled with multiple passes. Thirty patients were eventually considered to have malignant disease and aspiration biopsy was positive in 28 (93%) of these patients, including 25 of 26 with liver metastases (96%). There were two false-positive results and one minor complication. In 24 patients, conventional wide-bore needle biopsy was also performed. In thismore » group, 16 patients had a final diagnosis of hepatic malignancy. Aspiration biopsies were positive in 14 of these (87%) and conventional needle biopsies were positive in four (25%). Guided percutaneous fine-needle aspiration biopsy is recommended for pathologic diagnosis of hepatic malignancy because of its simplicity, high yield, and reasonable safety.« less
21 CFR 1020.32 - Fluoroscopic equipment.
Code of Federal Regulations, 2010 CFR
2010-04-01
.... Radiation therapy simulation systems shall be exempt from this requirement provided the systems are intended... 10, 2006, other than radiation therapy simulation systems, the following applies: (A) Neither the... fluoroscopic equipment manufactured on or after June 10, 2006, other than radiation therapy simulation systems...
Nacey, Nicholas C; Patrie, James T; Fox, Michael G
2016-11-01
The purpose of this study was to determine whether intraarticular sacroiliac joint injections provide greater immediate and short-term pain relief than periarticular sacroiliac joint injections do. The records of all fluoroscopically guided sacroiliac joint injections performed over a 4-year period were identified. Patients who received an injection of 0.5 mL of bupivacaine and 0.5 mL (20 mg) of triamcinolone and who had preinjection, immediate, and 1-week postinjection pain scores (0-10 numeric scale) were included. Images from the procedures were retrospectively reviewed by two musculoskeletal radiologists to determine intraarticular or periarticular administration of the injection with discrepancies resolved by consensus. One hundred thirteen injections in 99 patients (65 women, 34 men; mean age, 59.4 years) met the inclusion criteria. There were 55 intraarticular and 58 periarticular injections. The mean preinjection, immediate, and 1-week postinjection pain scores for the intraarticular injections were 6.0, 1.6, and 4.1 and for the periarticular injections were 6.1, 2.0, and 4.2. The mean immediate and 1-week postinjection pain reduction were statistically significant in both groups (p < 0.001). After adjustment for age, sex, preinjection pain score, time of year, and indication for injection, no significant difference in the preinjection to immediately postinjection change in pain between intraarticular and periarticular injections (mean change, 0.37; p = 0.319) or in the preinjection to 1-week postinjection change in pain (mean change, 0.06; p = 0.888) was noted. The mean fluoroscopy times were 42.4 seconds for intraarticular injections and 60.5 seconds for periarticular injections (p = 0.32). Although both intraarticular and periarticular sacroiliac joint injections provide statistically significant immediate and 1-week postinjection pain relief, no significant difference in the degree of pain relief achieved with intraarticular and periarticular injections was noted.
Economides, S; Hourdakis, C J; Kalivas, N; Kalathaki, M; Simantirakis, G; Tritakis, P; Manousaridis, G; Vogiatzi, S; Kipouros, P; Boziari, A; Kamenopoulou, V
2008-01-01
This study presents the results from a survey conducted by the Greek Atomic Energy Commission (GAEC), during the period 1998-2003, in 530 public and private owned fluoroscopic X-ray systems in Greece. Certain operational parameters for conventional and remote control systems were assessed, according to a quality control protocol developed by GAEC on the basis of the current literature. Public (91.5%) and private (81.5%) owned fluoroscopic units exhibit high-contrast resolution values over 1 lp mm(-1). Moreover, 88.5 and 87.1% of the fluoroscopic units installed in the public and private sector, respectively, present Maximum Patient Entrance Kerma Rate values lower than 100 mGy min(-1). Additionally, 68.3% of the units assessed were found to perform within the acceptance limits. Finally, the third quartile of the Entrance Surface Dose Rate distribution was estimated according to the Dose Reference Level definition and found equal to 35 mGy min(-1).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wunderle, K; Wayne State University School of Medicine, Detroit, MI; Godley, A
Purpose: The purpose of this investigation is to quantify various first half-value-layers (HVLs), second HVLs and homogeneity coefficients (HCs) for a state-of-the-art fluoroscope utilizing spectral (copper) filtration. Methods: A Radcal (Monrovia, Ca) AccuPro dosimeter with a 10×6-6 calibrated ionization chamber was used to measure air kerma for radiographic x-ray exposures made on a Siemens (Erlangen, Germany) Artis ZeeGo fluoroscope operated in the service mode. The ionization chamber was centered in the x-ray beam at 72 cm from the focal spot with a source-to-image-distance of 120 cm. The collimators were introduced to limit the x-ray field to approximately 5 cm ×more » 5 cm at the ionization chamber plane. Type-1100 aluminum filters, in 0.5 mm increments, were used to determine the HVL. Two HVL calculation methods were used, log-linear interpolation and Lambert-W interpolation as described by Mathieu [Med Phys, 38(8), 4546 (2011)]. Multiple measurements were made at 60, 80, 100, 120 kVp at spectral filtration thicknesses of 0, 0.1, 0.3, 0.6 and 0.9 mm. Results: First HVL, second HVL, and HCs are presented for the fluoroscopic x-ray beam spectra indicated above, with nearly identical results from the two interpolation methods. Accuracy of the set kVp was also determined and deviated less than 2%. First HVLs for fluoroscopic x-ray beam spectra without spectral filtration determined in our study were 7%–16% greater than previously published data by Fetterly et al. [Med Phys, 28, 205 (2001)]. However, the FDA minimum HVL requirements changed since that publication, requiring larger HVLs as of 2006. Additionally, x-ray tube and generator architecture have substantially changed over the last 15 years providing different beam spectra. Conclusion: X-ray beam quality characteristics for state-of-the-art fluoroscopes with spectral filtration have not been published. This study provides reference data which will be useful for defining beam qualities encountered on fluoroscopes using spectral filtration.« less
Fluoroscopic studies of the upper gastrointestinal tract: techniques and indications.
Sánchez-Carpintero de la Vega, M; García Villar, C
Fluoroscopic studies of the gastrointestinal tract are becoming increasing less common due to the introduction of other imaging techniques such as computed tomography and magnetic resonance imaging and to the increased availability of endoscopy. Nevertheless, fluoroscopic studies of the gastrointestinal tract continue to appear in clinical guidelines and some of their indications are still valid. These studies are dynamic, operator-dependent examinations that require training to obtain the maximum diagnostic performance. This review aims to describe the technique and bring the indications for this imaging modality up to date. Copyright © 2016 SERAM. Publicado por Elsevier España, S.L.U. All rights reserved.
Scholten, Paul M; Patel, Shounuck I; Christos, Paul J; Singh, Jaspal R
2015-04-01
To determine the relationship between sacroiliac joint (SIJ) contrast dispersal patterns during SIJ corticosteroid injection and pain relief at 2 and 8 weeks after the procedure. The association between the number of positive provocative SIJ physical examination maneuvers (minimum of one in all patients undergoing SIJ injection) and the patient's response to the intervention was also assessed. Retrospective chart review. Academic outpatient musculoskeletal practice. Fifty-four subjects who underwent therapeutic SIJ corticosteroid injection were screened for inclusion; 49 subjects were included in the final analysis. A retrospective review of electronic medical records identified patients who underwent SIJ corticosteroid injection. Fluoroscopic contrast flow patterns were categorized as type I (intra-articular injection with cephalad extension within the SIJ) or type II (intra-articular injection with poor cephalad extension). Self-reported numeric pain rating scale (NPRS) values at the time of injection and 2 and 8 weeks after the procedure were recorded. The number of positive provocative SIJ physical examination maneuvers at the time of the initial evaluation was also recorded. The primary outcome measure was the effect of contrast patterns (type I or type II) on change in NPRS values at 2 weeks and 8 weeks after the injection. The secondary outcome measure was the association between the number of positive provocative SIJ physical examination maneuvers and decrease in the level of pain after the procedure. At 2 weeks after the procedure, type I subjects demonstrated a significantly lower mean NPRS value compared with type II subjects (2.8 ± 1.4 versus 3.8 ± 1.6, respectively, P = .02). No statistically significant difference was observed at 8 weeks after the procedure. NPRS values were significantly reduced both at 2 weeks and 8 weeks, compared with baseline, in both subjects identified as having type I flow and those with type II flow (P < .0001 for all within-group comparisons). Fluoroscopically guided corticosteroid injections into the SIJ joint are effective in decreasing NPRS values in patients with SIJ-mediated pain. Delivery of corticosteroid to the superior portion of the SIJ leads to a greater reduction in pain at 2 weeks, but not at 8 weeks. Patients with at least one positive provocative maneuver should benefit from an intra-articular corticosteroid injection. Copyright © 2015 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.
Fallopian Tube Catheterization
Thurmond, Amy Suzanne
2013-01-01
Fallopian tube catheterization is used for treatment of infertility caused by proximal tubal occlusion, and has replaced surgical treatment for this condition. More recently, fallopian tube catheterization has been used for tubal sterilization. Interventional radiologists tested numerous methods for tubal occlusion using the rabbit as an animal model. As a result, a tubal device has recently been Food and Drug Administration approved for permanent sterilization using hysteroscopic guidance; it can also be placed fluoroscopically by fallopian tube catheterization as an “off-label” procedure. This is a 5-year continuation and update on a procedure that has been done by interventional radiologists for 25 years; history of the development of fallopian tube catheterization in women has been published in detail in this journal. Highlighted in this article will be description of the basic components needed for fallopian tube catheterization. PMID:24436565
DOE Office of Scientific and Technical Information (OSTI.GOV)
Goltz, Jan P., E-mail: Goltz@roentgen.uni-wuerzburg.de; Scholl, Anne; Ritter, Christian O.
The aim of this study is to evaluate the effectiveness and safety of percutaneously placed totally implantable venous-access ports (TIVAPs) of the forearm. Between January 2006 and October 2008, peripheral TIVAPs were implanted in 763 consecutive patients by ultrasound and fluoroscopic guidance. All catheters were implanted under local anesthesia and were tunneled subcutaneously. Indication, technical success, and complications were retrospectively analyzed according to Society of Interventional Radiology (SIR) criteria. Presence of antibiotic prophylaxis, periprocedurally administered drugs (e.g., sedation), and laboratory results at the time of implantation were analyzed. Maintenance during the service interval was evaluated. In total, 327,499 catheter-days weremore » analyzed. Technical success rate was 99.3%. Reasons for initial failure of implantation were either unexpected thrombosis of the subclavian vein, expanding tumor mass of the mediastinum, or failure of peripheral venous access due to fragile vessels. Mean follow-up was 430 days. There were 115 complications observed (15.1%, 0.03 per 100 catheter-days), of which 33 (4.3%) were classified as early (within 30 days from implantation) and 82 (10.7%) as late. Catheter-related venous thrombosis was found in 65 (8.5%) of 763 (0.02 per 100 catheter-days) TIVAPs. Infections were observed in 41 (5.4%) of 763 (0.01 per 100 catheter-days) devices. Other complications observed included dislocation of the catheter tip (0.8%), occlusion (0.1%), or rupture (0.1%) of the port catheter. Dislocated catheters were corrected during a second interventional procedure. In conclusion, implantation of percutaneously placed peripheral TIVAPs shows a high technical success rate and low risk of early complications when ultrasound and fluoroscopic guidance are used. Late complications are observed three times as often as early complications.« less
21 CFR 892.1650 - Image-intensified fluoroscopic x-ray system.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Image-intensified fluoroscopic x-ray system. 892.1650 Section 892.1650 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... through electronic amplification. This generic type of device may include signal analysis and display...
21 CFR 892.1650 - Image-intensified fluoroscopic x-ray system.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Image-intensified fluoroscopic x-ray system. 892.1650 Section 892.1650 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... through electronic amplification. This generic type of device may include signal analysis and display...
21 CFR 892.1650 - Image-intensified fluoroscopic x-ray system.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Image-intensified fluoroscopic x-ray system. 892.1650 Section 892.1650 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... through electronic amplification. This generic type of device may include signal analysis and display...
Lacey, Matthew; Lamplot, Joseph; Walley, Kempland C; DeAngelis, Joseph P; Ramappa, Arun J
2017-05-18
To describe an approach to anterior cruciate ligament (ACL) reconstruction using autologous hamstring by drilling via the anteromedial portal in the presence of an intramedullary (IM) femoral nail. Once preoperative imagining has characterized the proposed location of the femoral tunnel preparations are made to remove all of the hardware (locking bolts and IM nail). A diagnostic arthroscopy is performed in the usual fashion addressing all intra-articular pathology. The ACL remnant and lateral wall soft tissues are removed from the intercondylar, to provide adequate visualization of the ACL footprint. Femoral tunnel placement is performed using a transportal ACL guide with desired offset and the knee flexed to 2.09 rad. The Beath pin is placed through the guide starting at the ACL's anatomic footprint using arthroscopic visualization and/or fluoroscopic guidance. If resistance is met while placing the Beath pin, the arthroscopy should be discontinued and the obstructing hardware should be removed under fluoroscopic guidance. When the Beath pin is successfully placed through the lateral femur, it is overdrilled with a 4.5 mm Endobutton drill. If the Endobutton drill is obstructed, the obstructing hardware should be removed under fluoroscopic guidance. In this case, the obstruction is more likely during Endobutton drilling due to its larger diameter and increased rigidity compared to the Beath pin. The femoral tunnel is then drilled using a best approximation of the graft's outer diameter. We recommend at least 7 mm diameter to minimize the risk of graft failure. Autologous hamstring grafts are generally between 6.8 and 8.6 mm in diameter. After reaming, the knee is flexed to 1.57 rad, the arthroscope placed through the anteromedial portal to confirm the femoral tunnel position, referencing the posterior wall and lateral cortex. For a quadrupled hamstring graft, the gracilis and semitendinosus tendons are then harvested in the standard fashion. The tendons are whip stitched, quadrupled and shaped to match the diameter of the prepared femoral tunnel. If the diameter of the patient's autologous hamstring graft is insufficient to fill the prepared femoral tunnel, the autograft may be supplemented with an allograft. The remainder of the reconstruction is performed according to surgeon preference. The presence of retained hardware presents a challenge for surgeons treating patients with knee instability. In cruciate ligament reconstruction, distal femoral and proximal tibial implants hardware may confound tunnel placement, making removal of hardware necessary, unless techniques are adopted to allow for anatomic placement of the graft. This report demonstrates how the femoral tunnel can be created using the anteromedial portal instead of a transtibial approach for reconstruction of the ACL.
Objective characterization of airway dimensions using image processing.
Pepper, Victoria K; Francom, Christian; Best, Cameron A; Onwuka, Ekene; King, Nakesha; Heuer, Eric; Mahler, Nathan; Grischkan, Jonathan; Breuer, Christopher K; Chiang, Tendy
2016-12-01
With the evolution of medical and surgical management for pediatric airway disorders, the development of easily translated techniques of measuring airway dimensions can improve the quantification of outcomes of these interventions. We have developed a technique that improves the ability to characterize endoscopic airway dimensions using common bronchoscopic equipment and an open-source image-processing platform. We validated our technique of Endoscopic Airway Measurement (EAM) using optical instruments in simulation tracheas. We then evaluated EAM in a large animal model (Ovis aries, n = 5), comparing tracheal dimensions obtained with EAM to measurements obtained via 3-D fluoroscopic reconstruction. The animal then underwent resection of the measured segment, and direct measurement of this segment was performed and compared to radiographic measurements and those obtained using EAM. The simulation tracheas had a direct measurement of 13.6, 18.5, and 24.2 mm in diameter. The mean difference of diameter in simulation tracheas between direct measurements and measurements obtained using EAM was 0.70 ± 0.57 mm. The excised ovine tracheas had an average diameter of 18.54 ± 0.68 mm. The percent difference in diameter obtained from EAM and from 3-D fluoroscopic reconstruction when compared to measurement of the excised tracheal segment was 4.98 ± 2.43% and 10.74 ± 4.07% respectively. Comparison of these three measurements (EAM, measurement of resected trachea, 3-D fluoroscopic reconstruction) with repeated measures ANOVA demonstrated no statistical significance. Endoscopic airway measurement (EAM) provides equivalent measurements of the airway with the improved versatility of measuring non-circular and multi-level dimensions. Using optical bronchoscopic instruments and open-source image-processing software, our data supports preclinical and clinical translation of an accessible technique to provide objective quantification of airway diameter. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Radiology-guided forceps biopsy and airway stenting in severe airway stenosis
Li, Zong-Ming; Wu, Gang; Han, Xin-Wei; Ren, Ke-Wei; Zhu, Ming
2014-01-01
PURPOSE We aimed to determine the feasibility, safety, and effectiveness of radiology-guided forceps biopsy and airway stenting in patients with severe airway stenosis. MATERIALS AND METHODS This study involved 28 patients with severe airway stenosis who underwent forceps biopsy between October 2006 and September 2011. Chest multislice computed tomography was used to determine the location and extent of stenosis. Sixteen patients had tracheal stenosis, two patients had stenosis of the tracheal carina, six patients had stenosis of the left main bronchus, and four patients had stenosis of the right main bronchus. Forceps biopsy and stenting of the stenosed area were performed under fluoroscopic guidance in digital subtraction angiography and the biopsy specimens were analyzed histopathologically. We contacted the patients via phone call and utilized a standardized questionnaire to determine their medical condition during a postoperative three-month follow-up. RESULTS The technical success rate of radiology-guided forceps biopsy was 100%. Biopsy specimens were obtained in all patients. Dyspnea was relieved immediately after stent placement. No serious complications, such as tracheal hemorrhage or perforation, mediastinal emphysema, or asphyxia, occurred. CONCLUSION Radiology-guided forceps biopsy and airway stenting can be used for the emergency treatment of severe airway stenosis. This method appears to be safe and effective, and it may be an alternative therapeutic option in patients who cannot tolerate fiberoptic bronchoscopy. PMID:24808434
Garnon, Julien; Koch, Guillaume; Ramamurthy, Nitin; Caudrelier, Jean; Rao, Pramod; Tsoumakidou, Georgia; Cazzato, Roberto Luigi; Gangi, Afshin
2016-09-01
To review our initial experience with percutaneous CT and fluoroscopy-guided screw fixation of pathological shoulder-girdle fractures. Between May 2014 and June 2015, three consecutive oncologic patients (mean age 65 years; range 57-75 years) with symptomatic pathological shoulder-girdle fractures unsuitable for surgery and radiotherapy underwent percutaneous image-guided screw fixation. Fractures occurred through metastases (n = 2) or a post-ablation cavity (n = 1). Mechanical properties of osteosynthesis were adjudged superior to stand-alone cementoplasty in each case. Cannulated screws were placed under combined CT and fluoroscopic guidance with complementary radiofrequency ablation or cementoplasty to optimise local palliation and secure screw fixation, respectively, in two cases. Follow-up was undertaken every few weeks until mortality or most recent appointment. Four pathological fractures were treated in three patients (2 acromion, 1 clavicular, 1 coracoid). Mean size of associated lesion was 2.6 cm (range 1-4.5 cm). Technical success was achieved in all cases (100 %), without complications. Good palliation and restoration of mobility were observed in two cases at 2-3 months; one case could not be followed due to early post-procedural oncologic mortality. Percutaneous image-guided shoulder-girdle osteosynthesis appears technically feasible with good short-term efficacy in this complex patient subset. Further studies are warranted to confirm these promising initial results.
Scherman Rydhög, Jonas; Riisgaard de Blanck, Steen; Josipovic, Mirjana; Irming Jølck, Rasmus; Larsen, Klaus Richter; Clementsen, Paul; Lars Andersen, Thomas; Poulsen, Per Rugaard; Fredberg Persson, Gitte; Munck Af Rosenschold, Per
2017-04-01
The purpose of this study was to estimate the uncertainty in voluntary deep-inspiration breath-hold (DIBH) radiotherapy for locally advanced non-small cell lung cancer (NSCLC) patients. Perpendicular fluoroscopic movies were acquired in free breathing (FB) and DIBH during a course of visually guided DIBH radiotherapy of nine patients with NSCLC. Patients had liquid markers injected in mediastinal lymph nodes and primary tumours. Excursion, systematic- and random errors, and inter-breath-hold position uncertainty were investigated using an image based tracking algorithm. A mean reduction of 2-6mm in marker excursion in DIBH versus FB was seen in the anterior-posterior (AP), left-right (LR) and cranio-caudal (CC) directions. Lymph node motion during DIBH originated from cardiac motion. The systematic- (standard deviation (SD) of all the mean marker positions) and random errors (root-mean-square of the intra-BH SD) during DIBH were 0.5 and 0.3mm (AP), 0.5 and 0.3mm (LR), 0.8 and 0.4mm (CC), respectively. The mean inter-breath-hold shifts were -0.3mm (AP), -0.2mm (LR), and -0.2mm (CC). Intra- and inter-breath-hold uncertainty of tumours and lymph nodes were small in visually guided breath-hold radiotherapy of NSCLC. Target motion could be substantially reduced, but not eliminated, using visually guided DIBH. Copyright © 2017 Elsevier B.V. All rights reserved.
21 CFR 1020.31 - Radiographic equipment.
Code of Federal Regulations, 2012 CFR
2012-04-01
... fluoroscopic imaging or for recording images from the fluoroscopic image receptor, or computed tomography x-ray... and time, a preset number of pulses, or a preset radiation exposure to the image receptor. (i) Except... provided to indicate when the axis of the x-ray beam is perpendicular to the plane of the image receptor...
21 CFR 1020.31 - Radiographic equipment.
Code of Federal Regulations, 2013 CFR
2013-04-01
... fluoroscopic imaging or for recording images from the fluoroscopic image receptor, or computed tomography x-ray... and time, a preset number of pulses, or a preset radiation exposure to the image receptor. (i) Except... provided to indicate when the axis of the x-ray beam is perpendicular to the plane of the image receptor...
21 CFR 1020.31 - Radiographic equipment.
Code of Federal Regulations, 2014 CFR
2014-04-01
... fluoroscopic imaging or for recording images from the fluoroscopic image receptor, or computed tomography x-ray... and time, a preset number of pulses, or a preset radiation exposure to the image receptor. (i) Except... provided to indicate when the axis of the x-ray beam is perpendicular to the plane of the image receptor...
2016-01-01
Purposes. To present our series of 38 prone percutaneous nephrolithotomy procedures performed with renal access and tract dilation purely under ultrasound guidance and describe the benefits and challenges accompanying this approach. Methods. Thirty-eight consecutive patients presenting for percutaneous nephrolithotomy for renal stone removal were included in this prospective cohort study. Ultrasonographic imaging in the prone position was used to obtain percutaneous renal access and guide tract dilation. Fluoroscopic screening was used only for nephrostomy tube placement. Preoperative, intraoperative, and postoperative procedural and patient data were collected for analysis. Results. Mean age of patients was 52.7 ± 17.2 years. Forty-five percent of patients were male with mean BMI of 26.1 ± 7.3 and mean stone size of 27.2 ± 17.6 millimeters. Renal puncture was performed successfully with ultrasonographic guidance in all cases with mean puncture time of 135.4 ± 132.5 seconds. Mean dilation time was 11.5 ± 3.8 min and mean stone fragmentation time was 37.5 ± 29.0 min. Mean total operative time was 129.3 ± 41.1. No patients experienced any significant immediate postoperative complication. All patients were rendered stone-free and no additional secondary procedures were required. Conclusions. Ultrasound guidance for renal access and tract dilation in prone percutaneous nephrolithotomy is a feasible and effective technique. It can be performed safely with significantly reduced fluoroscopic radiation exposure to the patient, surgeon, and intraoperative personnel. PMID:27042176
Use of a retrievable metallic stent internally coated with silicone to treat airway obstruction.
Kim, Jin Hyoung; Shin, Ji Hoon; Song, Ho-Young; Lee, Se Chul; Kim, Kyung Rae; Park, Jung-Hoon
2008-08-01
The authors hypothesized that internally covered stents can reduce the rates of stent migration or mucous retention. The authors performed this study to report their experience with use of a retrievable metallic stent internally coated with silicone in patients with benign or malignant central airway obstructions. From 2004 to 2007, the authors performed fluoroscopically guided placement of a retrievable metallic stent internally coated with silicone in 26 consecutive patients with benign (n = 5) and malignant (n = 21) central airway obstructions. Stents were woven from a single thread of a 0.2-mm-diameter nitinol wire in a tubular configuration and internally covered with silicone membrane. Stent placement was technically and clinically successful in 93% (25/26) and 85% (22/26) of the patients, respectively. There were eight complications (31%) after stent placement, including tumor overgrowth (n = 2), stent migration (n = 1), symptomatic granulation tissue formation (n = 1), severe pain (n = 1), improper stent location (n = 1), symptomatic sputum retention (n = 1) and esophagobronchial fistula (n = 1). Because of complications, five stents were removed with a retrieval hook under fluoroscopic guidance without difficulty. The median survival period and stent patency were 150.0 days +/- 91.4 and 143.0 days +/- 26.7, respectively. The use of a retrievable metallic stent internally coated with silicone is a safe and effective method for relieving dyspnea, with adequate stent patency in patients with benign or malignant central airway obstructions. This stent design seems to be less prone to migration or mucous retention.
Fluoroscopic guidance for placing a double lumen endotracheal tube in adults.
Calenda, Emile; Baste, Jean Marc; Hajjej, Ridha; Rezig, Najiba; Moriceau, Jerome; Diallo, Yaya; Sghaeir, Slim; Danielou, Eric; Peillon, Christophe
2014-09-01
The aim of this study was to assess the right placement of the double lumen endotracheal tube with fluoroscopic guidance, which is used in first intention prior to the fiberscope in our institution. This was a prospective observational study. The study was conducted in vascular and thoracic operating rooms. We enrolled 205 patients scheduled for thoracic surgery, with ASA physical statuses of I (n = 37), II (n = 84), III (n = 80), and IV (n = 4). Thoracic procedures were biopsy (n = 20), wedge (n = 34), culminectomy (n = 6), lobectomy (n = 82), pneumonectomy (n = 4), sympathectomy (n = 9), symphysis (n = 47), and thymectomy (n = 3). The intubation with a double lumen tube was performed with the help of a laryngoscope. Tracheal and bronchial balloons were inflated and auscultation was performed after right and left exclusions. One shot was performed to locate the position of the bronchial tube and the hook. Fluoroscopic guidance was used to relocate the tube in case of a wrong position. When the fluoroscopic guidance failed to position the tube, a fiberscope was used. Perioperative collapse of the lung was assessed by the surgeon during the surgery. Correct fluoroscopic image was obtained after the first attempt in 58.5% of patients therefore a misplaced position was encountered in 41.5%. The fluoroscopic guidance allowed an exact repositioning in 99.5% of cases, and the mean duration of the procedure was 8 minutes. A fiberscope was required to move the hook for one patient. We did not notice a moving of the double lumen endotracheal tube during the surgery. The surgeon satisfaction was 100%. The fluoroscopy evidenced the right position of the double lumen tube and allowed a right repositioning in 99.5% of patients with a very simple implementation. Copyright © 2014. Published by Elsevier B.V.
Transthoracic needle biopsy of the lung
DiBardino, David M.; Yarmus, Lonny B.
2015-01-01
Background Image guided transthoracic needle aspiration (TTNA) is a valuable tool used for the diagnosis of countless thoracic diseases. Computed tomography (CT) is the most common imaging modality used for guidance followed by ultrasound (US) for lesions abutting the pleural surface. Novel approaches using virtual CT guidance have recently been introduced. The objective of this review is to examine the current literature for TTNA biopsy of the lung focusing on diagnostic accuracy and safety. Methods MEDLINE was searched from inception to October 2015 for all case series examining image guided TTNA. Articles focusing on fluoroscopic guidance as well as influence of rapid on-site evaluation (ROSE) on yield were excluded. The diagnostic accuracy, defined as the number of true positives divided by the number of biopsies done, as well as the complication rate [pneumothorax (PTX), bleeding] was examined for CT guided TTNA, US guided TTNA as well as CT guided electromagnetic navigational-TTNA (E-TTNA). Of the 490 articles recovered 75 were included in our analysis. Results The overall pooled diagnostic accuracy for CT guided TTNA using 48 articles that met the inclusion and exclusion criteria was 92.1% (9,567/10,383). A similar yield was obtained examining ten articles using US guided TTNA of 88.7% (446/503). E-TTNA, being a new modality, only had one pilot study citing a diagnostic accuracy of 83% (19/23). Pooled PTX and hemorrhage rates were 20.5% and 2.8% respectively for CT guided TTNA. The PTX rate was lower in US guided TTNA at a pooled rate of 4.4%. E-TTNA showed a similar rate of PTX at 20% with no incidence of bleeding in a single pilot study available. Conclusions Image guided TTNA is a safe and accurate modality for the biopsy of lung pathology. This study found similar yield and safety profiles with the three imaging modalities examined. PMID:26807279
Patient-bounded extrapolation using low-dose priors for volume-of-interest imaging in C-arm CT
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xia, Y.; Maier, A.; Berger, M.
2015-04-15
Purpose: Three-dimensional (3D) volume-of-interest (VOI) imaging with C-arm systems provides anatomical information in a predefined 3D target region at a considerably low x-ray dose. However, VOI imaging involves laterally truncated projections from which conventional reconstruction algorithms generally yield images with severe truncation artifacts. Heuristic based extrapolation methods, e.g., water cylinder extrapolation, typically rely on techniques that complete the truncated data by means of a continuity assumption and thus appear to be ad-hoc. It is our goal to improve the image quality of VOI imaging by exploiting existing patient-specific prior information in the workflow. Methods: A necessary initial step prior tomore » a 3D acquisition is to isocenter the patient with respect to the target to be scanned. To this end, low-dose fluoroscopic x-ray acquisitions are usually applied from anterior–posterior (AP) and medio-lateral (ML) views. Based on this, the patient is isocentered by repositioning the table. In this work, we present a patient-bounded extrapolation method that makes use of these noncollimated fluoroscopic images to improve image quality in 3D VOI reconstruction. The algorithm first extracts the 2D patient contours from the noncollimated AP and ML fluoroscopic images. These 2D contours are then combined to estimate a volumetric model of the patient. Forward-projecting the shape of the model at the eventually acquired C-arm rotation views gives the patient boundary information in the projection domain. In this manner, we are in the position to substantially improve image quality by enforcing the extrapolated line profiles to end at the known patient boundaries, derived from the 3D shape model estimate. Results: The proposed method was evaluated on eight clinical datasets with different degrees of truncation. The proposed algorithm achieved a relative root mean square error (rRMSE) of about 1.0% with respect to the reference reconstruction on nontruncated data, even in the presence of severe truncation, compared to a rRMSE of 8.0% when applying a state-of-the-art heuristic extrapolation technique. Conclusions: The method we proposed in this paper leads to a major improvement in image quality for 3D C-arm based VOI imaging. It involves no additional radiation when using fluoroscopic images that are acquired during the patient isocentering process. The model estimation can be readily integrated into the existing interventional workflow without additional hardware.« less
21 CFR 892.1660 - Non-image-intensified fluoroscopic x-ray system.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Non-image-intensified fluoroscopic x-ray system. 892.1660 Section 892.1660 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... of x-radiation into a visible image. This generic type of device may include signal analysis and...
21 CFR 892.1660 - Non-image-intensified fluoroscopic x-ray system.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Non-image-intensified fluoroscopic x-ray system. 892.1660 Section 892.1660 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... of x-radiation into a visible image. This generic type of device may include signal analysis and...
21 CFR 892.1660 - Non-image-intensified fluoroscopic x-ray system.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Non-image-intensified fluoroscopic x-ray system. 892.1660 Section 892.1660 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... of x-radiation into a visible image. This generic type of device may include signal analysis and...
28 CFR 552.13 - X-ray, major instrument, fluoroscope, or surgical intrusion.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 28 Judicial Administration 2 2010-07-01 2010-07-01 false X-ray, major instrument, fluoroscope, or... INSTITUTIONAL MANAGEMENT CUSTODY Searches of Housing Units, Inmates, and Inmate Work Areas § 552.13 X-ray, major... reasons only, with the inmate's consent. (b) The institution physician may authorize use of an X-ray for...
28 CFR 552.13 - X-ray, major instrument, fluoroscope, or surgical intrusion.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 28 Judicial Administration 2 2013-07-01 2013-07-01 false X-ray, major instrument, fluoroscope, or... INSTITUTIONAL MANAGEMENT CUSTODY Searches of Housing Units, Inmates, and Inmate Work Areas § 552.13 X-ray, major... reasons only, with the inmate's consent. (b) The institution physician may authorize use of an X-ray for...
28 CFR 552.13 - X-ray, major instrument, fluoroscope, or surgical intrusion.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 28 Judicial Administration 2 2014-07-01 2014-07-01 false X-ray, major instrument, fluoroscope, or... INSTITUTIONAL MANAGEMENT CUSTODY Searches of Housing Units, Inmates, and Inmate Work Areas § 552.13 X-ray, major... reasons only, with the inmate's consent. (b) The institution physician may authorize use of an X-ray for...
28 CFR 552.13 - X-ray, major instrument, fluoroscope, or surgical intrusion.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 28 Judicial Administration 2 2011-07-01 2011-07-01 false X-ray, major instrument, fluoroscope, or... INSTITUTIONAL MANAGEMENT CUSTODY Searches of Housing Units, Inmates, and Inmate Work Areas § 552.13 X-ray, major... reasons only, with the inmate's consent. (b) The institution physician may authorize use of an X-ray for...
28 CFR 552.13 - X-ray, major instrument, fluoroscope, or surgical intrusion.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 28 Judicial Administration 2 2012-07-01 2012-07-01 false X-ray, major instrument, fluoroscope, or... INSTITUTIONAL MANAGEMENT CUSTODY Searches of Housing Units, Inmates, and Inmate Work Areas § 552.13 X-ray, major... reasons only, with the inmate's consent. (b) The institution physician may authorize use of an X-ray for...
Torsional Dynamics of Steerable Needles: Modeling and Fluoroscopic Guidance
Swensen, John P.; Lin, MingDe; Okamura, Allison M.; Cowan, Noah J.
2017-01-01
Needle insertions underlie a diversity of medical interventions. Steerable needles provide a means by which to enhance existing needle-based interventions and facilitate new ones. Tip-steerable needles follow a curved path and can be steered by twisting the needle base during insertion, but this twisting excites torsional dynamics that introduce a discrepancy between the base and tip twist angles. Here, we model the torsional dynamics of a flexible rod—such as a tip-steerable needle—during subsurface insertion and develop a new controller based on the model. The torsional model incorporates time-varying mode shapes to capture the changing boundary conditions inherent during insertion. Numerical simulations and physical experiments using two distinct setups—stereo camera feedback in semi-transparent artificial tissue and feedback control with real-time X-ray imaging in optically opaque artificial tissue— demonstrate the need to account for torsional dynamics in control of the needle tip. PMID:24860026
Reliability of cystometrically obtained intravesical pressures in patients with neurogenic bladders.
Hess, Marika J; Lim, Lance; Yalla, Subbarao V
2002-01-01
Urodynamic studies in patients with neurogenic bladder detect and categorize neurourodynamic states, identify the risk for urologic sequelae, and determine the necessity for interventions. Because urodynamic studies serves as a prognostic indicator and guides patient management, pressure measurements during the study must accurately represent bladder function under physiologic conditions. Because nonphysiologic bladder filling used during conventional urodynamic studies may alter the bladder's accommodative properties, we studied how closely the intravesical pressures obtained before filling cystometry resembled those obtained during the filling phase of the cystometrogram. Twenty-two patients (21 men, 1 woman) with neurogenic bladders underwent standard urodynamic studies. A 16F triple-lumen catheter was inserted into the bladder, and the intravesical pressures were recorded (physiologic volume-specific pressures, PVSP). After emptying the bladder, an equal volume of normal saline solution was reinfused, and the pressures were recorded again (cystometric volume-specific pressure, CVSP). All patients underwent routine fluoroscopically assisted urodynamic testing. The PVSP and the CVSP were compared using the Wilcoxon signed ranks test. P value of .05 was significant. The mean PVSP was 14.5 cmH2O (range, 4-42 cmH2O) and mean CVSP was 20.6 cmH2O (range, 6-70 cmH2O). The CVSP was significantly higher than the PVSP (P = .01). Filling pressures during cystometry (CVSP) were significantly higher than the pressures measured at rest (PVSP). This study also suggests a strong correlation between PVSP and CVSP.
Transjugular intrahepatic portosystemic shunt creation using intravascular ultrasound guidance.
Farsad, Khashayar; Fuss, Cristina; Kolbeck, Kenneth J; Barton, Robert E; Lakin, Paul C; Keller, Frederick S; Kaufman, John A
2012-12-01
To describe the use of intravascular ultrasound (US) guidance for creation of transjugular intrahepatic portosystemic shunts (TIPSs) in humans. The initial 25 cases of intravascular US-guided TIPS were retrospectively compared versus the last 75 conventional TIPS cases during the same time period at the same institution in terms of the number of needle passes required to establish portal vein (PV) access, fluoroscopy time, and needle pass-related complications. Intravascular US-guided TIPS creation was successful in all cases, and there was no statistically significant difference in number of needle passes, fluoroscopy time, or needle pass-related complications between TIPS techniques. Intravascular US-guided TIPS creation was successful in cases in which conventional TIPS creation had failed as a result of PV thrombosis or distorted anatomy. Intravascular US guidance for TIPS creation was additionally useful in a patient with Budd-Chiari syndrome and in a patient with intrahepatic tumors. Intravascular US is a safe and reproducible means of real-time image guidance for TIPS creation, equivalent in efficacy to conventional fluoroscopic guidance. Real-time sonographic guidance with intravascular US may prove advantageous for cases in which there is PV thrombus, distorted anatomy, Budd-Chiari syndrome, or hepatic tumors. Copyright © 2012 SIR. Published by Elsevier Inc. All rights reserved.
Minimally invasive image-guided interventional management of hepatic artery pseudoaneurysms.
Vyas, Sameer; Khandelwal, Niranjan; Gupta, Vivek; Kamal Ahuja, Chirag; Kumar, Ajay; Kalra, Naveen; Kang, Mandeep; Prakash, Mahesh
2014-01-01
Hepatic artery pseudoaneurysms (HAPs) are uncommon entities. With the development of interventional techniques, their management has evolved from conventional (surgical) to non-surgical minimally invasive image-guided interventional techniques. Fifteen cases of HAPs who had undergone non-surgical interventional management in our department were reviewed. All patients were comprehensively evaluated for demographic information, morphology of pseudoaneurysm, indication for intervention and means of intervention, approach (endovascular or percutaneous), follow up and complications. Trauma and iatrogenic injury were most common causes of HAPs. Most of the HAPs (9 out of 10 in whom long follow up was available) managed with image-guided interventional techniques had favorable outcome. Minimally invasive image-guided interventional management is the preferred modality for HAPs.
Surgical Removal of Neglected Soft Tissue Foreign Bodies by Needle-Guided Technique
Ebrahimi, Ali; Radmanesh, Mohammad; Rabiei, Sohrab; kavoussi, Hossein
2013-01-01
Introduction: The phenomenon of neglected foreign bodies is a significant cause of morbidity in soft tissue injuries and may present to dermatologists as delayed wound healing, localized cellulitis and inflammation, abscess formation, or foreign body sensation. Localization and removal of neglected soft tissue foreign bodies (STFBs) is complex due to possible inflammation, indurations, granulated tissue, and fibrotic scar. This paper describes a simple method for the quick localization and (surgical) removal of neglected STFBs using two 23-gauge needles without ultrasonographic or fluoroscopic guidance. Materials and Methods: A technique based on the use of two 23-gauge needles was used in 41 neglected STFBs in order to achieve proper localization and fixation of foreign bodies during surgery. Results: Surgical removal was successful in 38 of 41 neglected STFBs (ranging from 2–13mm in diameter). Conclusion: The cross-needle-guided technique is an office-based procedure that allows the successful surgical removal of STFBs using minimal soft tissue exploration and dissection via proper localization, fixation, and propulsion of the foreign body toward the surface of the skin. PMID:24303416
Mabray, Marc C; Datta, Sanjit; Lillaney, Prasheel V; Moore, Teri; Gehrisch, Sonja; Talbott, Jason F; Levitt, Michael R; Ghodke, Basavaraj V; Larson, Paul S; Cooke, Daniel L
2016-07-01
Fluoroscopic systems in modern interventional suites have the ability to perform flat panel detector CT (FDCT) with navigational guidance. Fusion with MR allows navigational guidance towards FDCT occult targets. We aim to evaluate the accuracy of this system using single-pass needle placement in a deep brain stimulation (DBS) phantom. MR was performed on a head phantom with DBS lead targets. The head phantom was placed into fixation and FDCT was performed. FDCT and MR datasets were automatically fused using the integrated guidance system (iGuide, Siemens). A DBS target was selected on the MR dataset. A 10 cm, 19 G needle was advanced by hand in a single pass using laser crosshair guidance. Radial error was visually assessed against measurement markers on the target and by a second FDCT. Ten needles were placed using CT-MR fusion and 10 needles were placed without MR fusion, with targeting based solely on FDCT and fusion steps repeated for every pass. Mean radial error was 2.75±1.39 mm as defined by visual assessment to the centre of the DBS target and 2.80±1.43 mm as defined by FDCT to the centre of the selected target point. There were no statistically significant differences in error between MR fusion and non-MR guided series. Single pass needle placement in a DBS phantom using FDCT guidance is associated with a radial error of approximately 2.5-3.0 mm at a depth of approximately 80 mm. This system could accurately target sub-centimetre intracranial lesions defined on MR. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Percutaneous coil embolization of massive pelvic pseudoaneurysm in an infant.
Lillis, Anna P; Shaikh, Raja; Alomari, Ahmad I; Chaudry, Gulraiz
2015-06-01
Iatrogenic pseudoaneurysm formation is an uncommon but potentially serious complication of cardiac catheterization. This case report describes diagnosis and treatment of a large left external iliac artery pseudoaneurysm in a 3-month-old boy following cardiac catheterization and aortic balloon dilatation for aortic coarctation. A 4-cm pulsatile mass in the left hemipelvis was discovered on MRI performed 6 weeks later for possible tethered spinal cord. Sonography and angiography showed a large pseudoaneurysm of the left external iliac artery just distal to the iliac bifurcation with no flow in the external iliac artery distal to the pseudoaneurysm. Percutaneous US-guided thrombin injection was performed twice, with partial recanalization after each treatment. The residual portion of the pseudoaneurysm was then successfully embolized with percutaneous coils deployed under US and fluoroscopic guidance.
Callahan, Michael J; Talmadge, Jennifer M; MacDougall, Robert D; Kleinman, Patricia L; Taylor, George A; Buonomo, Carlo
2017-04-01
In our experience, questions about the appropriate use of enteric contrast media for pediatric fluoroscopic studies are common. The purpose of this article is to provide a comprehensive review of enteric contrast media used for pediatric fluoroscopy, highlighting the routine use of these media at a large tertiary care pediatric teaching hospital.
Actual Time Required for Dynamic Fluoroscopic Intraoperative Cholangiography
Whitwam, Paul; Turner, David; Kennedy, Kathy; Hashmi, Syed
2005-01-01
Objectives: This study was undertaken to determine the actual amount of time a dynamic fluoroscopic intraoperative cholangiogram adds to a laparoscopic cholecystectomy. A secondary objective was to define the information gained from this procedure. Methods: A consecutive case study of 52 patients undergoing laparoscopic cholecystectomy was used. Time was recorded from placement of a laparoscopic hemoclip across the cystic duct at its junction with the gallbladder until successful completion of the intraoperative cholangiogram. The mean, median, and range of times for these cases, as well as the results and false-negative rates, were determined. Results: Cholangiography was successfully completed in 96% of patients. The mean time added to laparoscopic cholecystectomy by the addition of dynamic fluoroscopic intraoperative cholangiography was 4.3 minutes. The median time was 3.0 minutes. The times ranged from 2.0 minutes to 16.0 minutes. Choledocholithiasis was present in 15.4% of these patients. The false-positive rate was zero in this study. Conclusions: Dynamic fluoroscopic intraoperative cholangiogram was fast and efficient. The information gained was significant in that 15% of patients proceeded on to laparoscopic common bile duct exploration. We conclude that intraoperative cholangiography should be a routine addition to laparoscopic cholecystectomy. PMID:15984705
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rana, V K; Vijayan, S; Rudin, S R
Purpose: To determine the appropriate calibration factor to use when calculating skin dose with our real-time dose-tracking system (DTS) during neuro-interventional fluoroscopic procedures by evaluating the difference in backscatter from different phantoms and as a function of entrance-skin field area. Methods: We developed a dose-tracking system to calculate and graphically display the cumulative skin-dose distribution in real time. To calibrate the DTS for neuro-interventional procedures, a phantom is needed that closely approximates the scattering properties of the head. We compared the x-ray backscatter from eight phantoms: 20-cm-thick solid water, 16-cm diameter water-filled container, 16-cm CTDI phantom, modified-ANSI head phantom, 20-cm-thickmore » PMMA, Kyoto-Kagaku PBU- 50 head, Phantom-Labs SK-150 head, and RSD RS-240T head. The phantoms were placed on the patient table with the entrance surface at 15 cm tube-side from the isocenter of a Toshiba Infinix C-arm, and the entrance-skin exposure was measured with a calibrated 6-cc PTW ionization chamber. The measurement included primary radiation, backscatter from the phantom and forward scatter from the table and pad. The variation in entrance-skin exposure was also measured as a function of the skin-entrance area for a 30x30 cm by 20-cm-thick PMMA phantom and the SK-150 head phantom using four different added beam filters. Results: The entranceskin exposure values measured for eight different phantoms differed by up to 12%, while the ratio of entrance exposure of all phantoms relative to solid water showed less than 3% variation with kVp. The change in entrance-skin exposure with entrance-skin area was found to differ for the SK-150 head compared to the 20-cm PMMA phantom and the variation with field area was dependent on the added beam filtration. Conclusion: To accurately calculate skin dose for neuro-interventional procedures with the DTS, the phantom for calibration should be carefully chosen since different phantoms can contribute different backscatter for identical exposure parameters. Research supported in part by Toshiba Medical Systems and NIH Grants R43FD0158401, R44FD0158402 and R01EB002873.« less
Villard, P F; Vidal, F P; Hunt, C; Bello, F; John, N W; Johnson, S; Gould, D A
2009-11-01
We present here a simulator for interventional radiology focusing on percutaneous transhepatic cholangiography (PTC). This procedure consists of inserting a needle into the biliary tree using fluoroscopy for guidance. The requirements of the simulator have been driven by a task analysis. The three main components have been identified: the respiration, the real-time X-ray display (fluoroscopy) and the haptic rendering (sense of touch). The framework for modelling the respiratory motion is based on kinematics laws and on the Chainmail algorithm. The fluoroscopic simulation is performed on the graphic card and makes use of the Beer-Lambert law to compute the X-ray attenuation. Finally, the haptic rendering is integrated to the virtual environment and takes into account the soft-tissue reaction force feedback and maintenance of the initial direction of the needle during the insertion. Five training scenarios have been created using patient-specific data. Each of these provides the user with variable breathing behaviour, fluoroscopic display tuneable to any device parameters and needle force feedback. A detailed task analysis has been used to design and build the PTC simulator described in this paper. The simulator includes real-time respiratory motion with two independent parameters (rib kinematics and diaphragm action), on-line fluoroscopy implemented on the Graphics Processing Unit and haptic feedback to feel the soft-tissue behaviour of the organs during the needle insertion.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vijayan, S; Rana, V; Nagesh, S Setlur
Purpose: To determine the reduction of integral dose to the patient when using the micro-angiographic fluoroscope (MAF) compared to when using the standard flat-panel detector (FPD) for the techniques used during neurointerventional procedures. Methods: The MAF is a small field-of-view, high resolution x-ray detector which captures 1024 x 1024 pixels with an effective pixel size of 35μm and is capable of real-time imaging up to 30 frames per second. The MAF was used in neuro-interventions during those parts of the procedure when high resolution was needed and the FPD was used otherwise. The technique parameters were recorded when each detectormore » was used and the kerma-area-product (KAP) per image frame was determined. KAP values were calculated for seven neuro interventions using premeasured calibration files of output as a function of kVp and beam filtration and included the attenuation of the patient table for the frontal projections to be more representative of integral patient dose. The air kerma at the patient entrance was multiplied by the beam area at that point to obtain the KAP values. The ranges of KAP values per frame were determined for the range of technique parameters used during the clinical procedures. To appreciate the benefit of the higher MAF resolution in the region of interventional activity, DA technique parameters were generally used with the MAF. Results: The lowest and highest values of KAP per frame for the MAF in DA mode were 4 and 50 times lower, respectively, compared to those of the FPD in pulsed fluoroscopy mode. Conclusion: The MAF was used in those parts of the clinical procedures when high resolution and image quality was essential. The integral patient dose as represented by the KAP value was substantially lower when using the MAF than when using the FPD due to the much smaller volume of tissue irradiated. This research was supported in part by Toshiba Medical Systems Corporation and NIH Grant R01EB002873.« less
NASA Astrophysics Data System (ADS)
Davies, Andrew G.; Cowen, Arnold R.; Bruijns, Tom J. C.
1999-05-01
We are currently in an era of active development of the digital X-ray imaging detectors that will serve the radiological communities in the new millennium. The rigorous comparative physical evaluations of such devices are therefore becoming increasingly important from both the technical and clinical perspectives. The authors have been actively involved in the evaluation of a clinical demonstration version of a flat-panel dynamic digital X-ray image detector (or FDXD). Results of objective physical evaluation of this device have been presented elsewhere at this conference. The imaging performance of FDXD under radiographic exposure conditions have been previously reported, and in this paper a psychophysical evaluation of the FDXD detector operating under continuous fluoroscopic conditions is presented. The evaluation technique employed was the threshold contrast detail detectability (TCDD) technique, which enables image quality to be measured on devices operating in the clinical environment. This approach addresses image quality in the context of both the image acquisition and display processes, and uses human observers to measure performance. The Leeds test objects TO[10] and TO[10+] were used to obtain comparative measurements of performance on the FDXD and two digital spot fluorography (DSF) systems, one utilizing a Plumbicon camera and the other a state of the art CCD camera. Measurements were taken at a range of detector entrance exposure rates, namely 6, 12, 25 and 50 (mu) R/s. In order to facilitate comparisons between the systems, all fluoroscopic image processing such as noise reduction algorithms, were disabled during the experiments. At the highest dose rate FDXD significantly outperformed the DSF comparison systems in the TCDD comparisons. At 25 and 12 (mu) R/s all three-systems performed in an equivalent manner and at the lowest exposure rate FDXD was inferior to the two DSF systems. At standard fluoroscopic exposures, FDXD performed in an equivalent manner to the DSF systems for the TCDD comparisons. This would suggest that FDXD would therefore perform adequately in a clinical fluoroscopic environment and our initial clinical experiences support this. Noise reduction processing of the fluoroscopic data acquired on FDXD was also found to further improve TCDD performance for FDXD. FDXD therefore combines acceptable fluoroscopic performance with excellent radiographic (snap shot) imaging fidelity, allowing the possibility of a universal x-ray detector to be developed, based on FDXD's technology. It is also envisaged that fluoroscopic performance will be improved by the development of digital image enhancement techniques specifically tailored to the characteristics of the FDXD detector.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xu, X; Lin, H; Gao, Y
Purpose: To study how eyeglass design features and postures of the interventional radiologist affect the radiation dose to the lens of the eye. Methods: A mesh-based deformable phantom, consisting of an ultra-fine eye model, was used to simulate postures of a radiologist in fluoroscopically guided interventional procedure (facing the patient, 45 degree to the left, and 45 degree to the right). Various eyewear design features were studied, including the shape, lead-equivalent thickness, and separation from the face. The MCNPX Monte Carlo code was used to simulate the X-ray source used for the transcatheter arterial chemoembolization procedure (The X-ray tube ismore » located 35 cm from the ground, emitting X-rays toward to the ceiling; Field size is 40cm X 40cm; X-ray tube voltage is 90 kVp). Experiments were also performed using dosimeter placed on a physical phantom behind eyeglasses. Results: Without protective eyewear, the radiologist’s eye lens can receive an annual dose equivalent of about 80 mSv. When wearing a pair of lead eyeglasses with lead-equivalent of 0.5-mm Pb, the annual dose equivalent of the eye lens is reduced to 31.47 mSv, but both exceed the new ICRP limit of 20 mSv. A face shield with a lead-equivalent of 0.125-mm Pb in the shape of a semi-cylinder (13cm in radius and 20-cm in height) would further reduce the exposure to the lens of the eye. Examination of postures and eyeglass features reveal surprising information, including that the glass-to-eye separation also plays an important role in the dose to the eye lens from scattered X-ray from underneath and the side. Results are in general agreement with measurements. Conclusion: There is an urgent need to further understand the relationship between the radiation environment and the radiologist’s eyewear and posture in order to provide necessary protection to the interventional radiologists under newly reduced dose limits.« less
Computed tomography image-guided surgery in complex acetabular fractures.
Brown, G A; Willis, M C; Firoozbakhsh, K; Barmada, A; Tessman, C L; Montgomery, A
2000-01-01
Eleven complex acetabular fractures in 10 patients were treated by open reduction with internal fixation incorporating computed tomography image guided software intraoperatively. Each of the implants placed under image guidance was found to be accurate and without penetration of the pelvis or joint space. The setup time for the system was minimal. Accuracy in the range of 1 mm was found when registration was precise (eight cases) and was in the range of 3.5 mm when registration was only approximate (three cases). Added benefits included reduced intraoperative fluoroscopic time, less need for more extensive dissection, and obviation of additional surgical approaches in some cases. Compared with a series of similar fractures treated before this image guided series, the reduction in operative time was significant. For patients with complex anterior and posterior combined fractures, the average operation times with and without application of three-dimensional imaging technique were, respectively, 5 hours 15 minutes and 6 hours 14 minutes, revealing 16% less operative time for those who had surgery using image guidance. In the single column fracture group, the operation time for those with three-dimensional imaging application, was 2 hours 58 minutes and for those with traditional surgery, 3 hours 42 minutes, indicating 20% less operative time for those with imaging modality. Intraoperative computed tomography guided imagery was found to be an accurate and suitable method for use in the operative treatment of complex acetabular fractures with substantial displacement.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Garnon, Julien, E-mail: juliengarnon@gmail.com; Koch, Guillaume, E-mail: Guillaume.koch@gmail.com; Ramamurthy, Nitin, E-mail: Nitin-ramamurthy@hotmail.com
ObjectiveTo review our initial experience with percutaneous CT and fluoroscopy-guided screw fixation of pathological shoulder-girdle fractures.Materials and MethodsBetween May 2014 and June 2015, three consecutive oncologic patients (mean age 65 years; range 57–75 years) with symptomatic pathological shoulder-girdle fractures unsuitable for surgery and radiotherapy underwent percutaneous image-guided screw fixation. Fractures occurred through metastases (n = 2) or a post-ablation cavity (n = 1). Mechanical properties of osteosynthesis were adjudged superior to stand-alone cementoplasty in each case. Cannulated screws were placed under combined CT and fluoroscopic guidance with complementary radiofrequency ablation or cementoplasty to optimise local palliation and secure screw fixation, respectively, in two cases. Follow-up wasmore » undertaken every few weeks until mortality or most recent appointment.ResultsFour pathological fractures were treated in three patients (2 acromion, 1 clavicular, 1 coracoid). Mean size of associated lesion was 2.6 cm (range 1–4.5 cm). Technical success was achieved in all cases (100 %), without complications. Good palliation and restoration of mobility were observed in two cases at 2–3 months; one case could not be followed due to early post-procedural oncologic mortality.ConclusionPercutaneous image-guided shoulder-girdle osteosynthesis appears technically feasible with good short-term efficacy in this complex patient subset. Further studies are warranted to confirm these promising initial results.« less
HEU Holdup Measurements in the 321-M Draw Bench, Straightener, and Fluoroscope Components
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dewberry, R.A.
The Analytical Development Section of Savannah River Technology Center (SRTC) was requested by the Facilities Disposition Division (FDD) to determine the holdup of enriched uranium in the 321-M facility as part of an overall deactivation project of the facility. This report covers holdup measurements of uranium residue on the draw bench, straightener, and the fluoroscope components of the 321-M facility.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shiinoki, T; Shibuya, K; Sawada, A
Purpose: The new real-time tumor-tracking radiotherapy (RTRT) system was installed in our institution. This system consists of two x-ray tubes and color image intensifiers (I.I.s). The fiducial marker which was implanted near the tumor was tracked using color fluoroscopic images. However, the implantation of the fiducial marker is very invasive. Color fluoroscopic images enable to increase the recognition of the tumor. However, these images were not suitable to track the tumor without fiducial marker. The purpose of this study was to investigate the feasibility of markerless tracking using dual energy colored fluoroscopic images for real-time tumor-tracking radiotherapy system. Methods: Themore » colored fluoroscopic images of static and moving phantom that had the simulated tumor (30 mm diameter sphere) were experimentally acquired using the RTRT system. The programmable respiratory motion phantom was driven using the sinusoidal pattern in cranio-caudal direction (Amplitude: 20 mm, Time: 4 s). The x-ray condition was set to 55 kV, 50 mA and 105 kV, 50 mA for low energy and high energy, respectively. Dual energy images were calculated based on the weighted logarithmic subtraction of high and low energy images of RGB images. The usefulness of dual energy imaging for real-time tracking with an automated template image matching algorithm was investigated. Results: Our proposed dual energy subtraction improve the contrast between tumor and background to suppress the bone structure. For static phantom, our results showed that high tracking accuracy using dual energy subtraction images. For moving phantom, our results showed that good tracking accuracy using dual energy subtraction images. However, tracking accuracy was dependent on tumor position, tumor size and x-ray conditions. Conclusion: We indicated that feasibility of markerless tracking using dual energy fluoroscopic images for real-time tumor-tracking radiotherapy system. Furthermore, it is needed to investigate the tracking accuracy using proposed dual energy subtraction images for clinical cases.« less
Burns, Sean; Thornton, Raymond; Dauer, Lawrence T; Quinn, Brian; Miodownik, Daniel; Hak, David J
2013-07-17
Despite recommendations to do so, few orthopaedists wear leaded glasses when performing operative fluoroscopy. Radiation exposure to the ocular lens causes cataracts, and regulatory limits for maximum annual occupational exposure to the eye continue to be revised downward. Using anthropomorphic patient and surgeon phantoms, radiation dose at the surgeon phantom's lens was measured with and without leaded glasses during fluoroscopic acquisition of sixteen common pelvic and hip views. The magnitude of lens dose reduction from leaded glasses was calculated by dividing the unprotected dose by the dose measured behind leaded glasses. On average, the use of leaded glasses reduced radiation to the surgeon phantom's eye by tenfold, a 90% reduction in dose. However, there was widespread variation in the amount of radiation that reached the phantom surgeon's eye among the various radiographic projections we studied. Without leaded glasses, the dose measured at the surgeon's lens varied more than 250-fold among these sixteen different views. In addition to protecting the surgeon's eye from the deleterious effects of radiation, the use of leaded glasses could permit an orthopaedist to perform fluoroscopic views on up to ten times more patients before reaching the annual dose limit of 20 mSv of radiation to the eye recommended by the International Commission on Radiological Protection. Personal safety and adherence to limits of occupational radiation exposure should compel orthopaedists to wear leaded glasses for fluoroscopic procedures if other protective barriers are not in use. Leaded glasses are a powerful tool for reducing the orthopaedic surgeon's lens exposure to radiation during acquisition of common intraoperative fluoroscopic views.
Cost of a recall of a single-center experience managing the Riata defibrillator lead.
Hussain, Sarah; Moorman, Liza; Moorman, J Randall; DiMarco, John P; Malhotra, Rohit; Darby, Andrew; Bilchick, Kenneth; Mangrum, J Michael; Ferguson, John D; Mason, Pamela K
2015-01-15
Riata and Riata ST defibrillator leads (St. Jude Medical, Sylmar, California) were recalled in 2011 due to increased risk of insulation failure leading to externalized cables. Fluoroscopic screening can identify insulation failure, although the relation between mechanical failure and electrical failure is unclear. At the time of the recall, the University of Virginia developed a screening program, including fluoroscopic evaluation, education sessions, device interrogation, and remote monitoring for patients with this defibrillator lead. The aim of this study was to review the outcomes of the screening program, including costs, which were absorbed by our institution. Costs were calculated using Medicare reimbursement estimates. Forty-eight patients participated in the screening program. At initial screening, 31% were found to have evidence of insulation failure but electrical function was normal in all leads. The cost of this program was $35,358.72. The cost per diagnosis of mechanical lead failure was $2,357.25. During 2 years of follow-up, 1 patient experienced Riata lead electrical failure without fluoroscopic evidence of insulation failure. Patients were more likely to have a lead revision if there was evidence of insulation failure. Lead revisions occurred at the time of generator change in 88% of patients with insulation failure but in only 14% of patients with a fluoroscopically normal lead (p = 0.04). The cost of recall-related defibrillator lead revisions was $81,704.55. In conclusion, our Riata screening program added expense without clear benefit to patients. In fact, patients may have been put at more risk by undergoing defibrillator lead revisions based solely on the results of the fluoroscopic screening. Copyright © 2015 Elsevier Inc. All rights reserved.
Edge enhancement algorithm for low-dose X-ray fluoroscopic imaging.
Lee, Min Seok; Park, Chul Hee; Kang, Moon Gi
2017-12-01
Low-dose X-ray fluoroscopy has continually evolved to reduce radiation risk to patients during clinical diagnosis and surgery. However, the reduction in dose exposure causes quality degradation of the acquired images. In general, an X-ray device has a time-average pre-processor to remove the generated quantum noise. However, this pre-processor causes blurring and artifacts within the moving edge regions, and noise remains in the image. During high-pass filtering (HPF) to enhance edge detail, this noise in the image is amplified. In this study, a 2D edge enhancement algorithm comprising region adaptive HPF with the transient improvement (TI) method, as well as artifacts and noise reduction (ANR), was developed for degraded X-ray fluoroscopic images. The proposed method was applied in a static scene pre-processed by a low-dose X-ray fluoroscopy device. First, the sharpness of the X-ray image was improved using region adaptive HPF with the TI method, which facilitates sharpening of edge details without overshoot problems. Then, an ANR filter that uses an edge directional kernel was developed to remove the artifacts and noise that can occur during sharpening, while preserving edge details. The quantitative and qualitative results obtained by applying the developed method to low-dose X-ray fluoroscopic images and visually and numerically comparing the final images with images improved using conventional edge enhancement techniques indicate that the proposed method outperforms existing edge enhancement methods in terms of objective criteria and subjective visual perception of the actual X-ray fluoroscopic image. The developed edge enhancement algorithm performed well when applied to actual low-dose X-ray fluoroscopic images, not only by improving the sharpness, but also by removing artifacts and noise, including overshoot. Copyright © 2017 Elsevier B.V. All rights reserved.
Chiu, C K; Kwan, M K; Chan, C Y W; Schaefer, C; Hansen-Algenstaedt, N
2015-08-01
We undertook a retrospective study investigating the accuracy and safety of percutaneous pedicle screws placed under fluoroscopic guidance in the lumbosacral junction and lumbar spine. The CT scans of patients were chosen from two centres: European patients from University Medical Center Hamburg-Eppendorf, Germany, and Asian patients from the University of Malaya, Malaysia. Screw perforations were classified into grades 0, 1, 2 and 3. A total of 880 percutaneous pedicle screws from 203 patients were analysed: 614 screws from 144 European patients and 266 screws from 59 Asian patients. The mean age of the patients was 58.8 years (16 to 91) and there were 103 men and 100 women. The total rate of perforation was 9.9% (87 screws) with 7.4% grade 1, 2.0% grade 2 and 0.5% grade 3 perforations. The rate of perforation in Europeans was 10.4% and in Asians was 8.6%, with no significant difference between the two (p = 0.42). The rate of perforation was the highest in S1 (19.4%) followed by L5 (14.9%). The accuracy and safety of percutaneous pedicle screw placement are comparable to those cited in the literature for the open method of pedicle screw placement. Greater caution must be taken during the insertion of L5 and S1 percutaneous pedicle screws owing to their more angulated pedicles, the anatomical variations in their vertebral bodies and the morphology of the spinal canal at this location. ©2015 The British Editorial Society of Bone & Joint Surgery.
Koontz, Nicholas A; Wiggins, Richard H; Stoddard, Gregory J; Shah, Lubdha M
2017-10-01
There is a paucity of evidence-based literature regarding the advantages and disadvantages of the interlaminar approach and needle bevel orientation for performing a lumbar interlaminar epidural steroid injection (ESI). The purpose of this study was to determine if superior versus inferior lamina approach, needle bevel tip orientation, or both may predispose to inadvertent nonepidural penetration during lumbar interlaminar ESI. A prospective study was performed of patients with low back pain with or without radicular pain or neurogenic claudication referred for lumbar interlaminar ESI. Two hundred eleven patients were randomized by interlaminar approach (superior vs inferior) and bevel tip orientation (cranial vs caudal). Lumbar interlaminar ESI was performed by six interventionalists of varying levels of experience using fluoroscopic guidance with curved tip epidural needles, using loss-of-resistance technique and confirmation with contrast opacification. Exact Poisson regression was used to model the study outcome. Two hundred twenty-one lumbar interlaminar ESIs were performed on 211 patients, randomized to a superior (n = 121) or inferior lamina approach (n = 100) and to a cranial (n = 103) or caudal (n = 118) orientation of the bevel tip. Epidural needle placement was confirmed in 96.4% (n = 213) of cases. Nonepidural needle placement was most commonly associated with superior lamina approach and caudal bevel tip orientation, which was marginally significant (adjusted risk ratio, 6.88; 95% CI, 0.93-∞; p = 0.059). Inadvertent nonepidural needle penetration during fluoroscopically guided lumbar interlaminar ESI appears to be affected by approach, with superior lamina approach and caudal bevel tip orientation being the least favorable technique.
Jejunal feeding tubes can be efficiently and independently placed by intensive care unit teams.
Welpe, Pascal; Frutiger, Adrian; Vanek, Patrik; Kleger, Gian-Reto
2010-01-01
Nutrition support is an important therapeutic measure in critically ill patients. Several studies have shown that the enteral route is preferable to the parenteral route. Insertion of a feeding tube beyond the ligament of Treitz combined with continuous gastric drainage will reduce regurgitation and probably also the rate of nosocomial pneumonia. This study was conducted to assess the safety, success rate, and time required to establish jejunal nutrition by the fluoroscopy-guided technique in intensive care unit (ICU) patients. This was a prospective observational study in the ICUs of a 300-bed and a 600-bed community hospital. Indications were large gastric residuals during attempted gastric feeding, severe acute pancreatitis, or recurrent aspiration. Feeding tubes were introduced by the ICU staff at bedside under fluoroscopic guidance (a senior ICU physician and a resident or a registered ICU nurse). The correct jejunal position was documented by the application of a radiopaque contrast medium through the tube. After confirmation of the correct position, jejunal tube feeding was immediately started. The insertion procedure in 38 patients lasted a median of 17 minutes. The median time from decision to place the tube until start of enteral feeding was 141 minutes. The success rate was 84.2%. No adverse events were observed. Fluoroscopic placement of a jejunal feeding tube at the bedside is fast, is safe, and has a high success rate when performed by well-trained ICU staff. Using this method makes the ICU team more self-sufficient when critically ill patients require enteral nutrition and no gastroenterologist is available.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jones, A; Pasciak, A
Purpose: Skin dosimetry is important for fluoroscopically-guided interventions, as peak skin doses (PSD) that Result in skin reactions can be reached during these procedures. The purpose of this study was to assess the accuracy of different indirect dose estimates and to determine if PSD can be calculated within ±50% for embolization procedures. Methods: PSD were measured directly using radiochromic film for 41 consecutive embolization procedures. Indirect dose metrics from procedures were collected, including reference air kerma (RAK). Four different estimates of PSD were calculated and compared along with RAK to the measured PSD. The indirect estimates included a standard method,more » use of detailed information from the RDSR, and two simplified calculation methods. Indirect dosimetry was compared with direct measurements, including an analysis of uncertainty associated with film dosimetry. Factors affecting the accuracy of the indirect estimates were examined. Results: PSD calculated with the standard calculation method were within ±50% for all 41 procedures. This was also true for a simplified method using a single source-to-patient distance (SPD) for all calculations. RAK was within ±50% for all but one procedure. Cases for which RAK or calculated PSD exhibited large differences from the measured PSD were analyzed, and two causative factors were identified: ‘extreme’ SPD and large contributions to RAK from rotational angiography or runs acquired at large gantry angles. When calculated uncertainty limits [−12.8%, 10%] were applied to directly measured PSD, most indirect PSD estimates remained within ±50% of the measured PSD. Conclusions: Using indirect dose metrics, PSD can be determined within ±50% for embolization procedures, and usually to within ±35%. RAK can be used without modification to set notification limits and substantial radiation dose levels. These results can be extended to similar procedures, including vascular and interventional oncology. Film dosimetry is likely an unnecessary effort for these types of procedures.« less
Automated quantification of lumbar vertebral kinematics from dynamic fluoroscopic sequences
NASA Astrophysics Data System (ADS)
Camp, Jon; Zhao, Kristin; Morel, Etienne; White, Dan; Magnuson, Dixon; Gay, Ralph; An, Kai-Nan; Robb, Richard
2009-02-01
We hypothesize that the vertebra-to-vertebra patterns of spinal flexion and extension motion of persons with lower back pain will differ from those of persons who are pain-free. Thus, it is our goal to measure the motion of individual lumbar vertebrae noninvasively from dynamic fluoroscopic sequences. Two-dimensional normalized mutual information-based image registration was used to track frame-to-frame motion. Software was developed that required the operator to identify each vertebra on the first frame of the sequence using a four-point "caliper" placed at the posterior and anterior edges of the inferior and superior end plates of the target vertebrae. The program then resolved the individual motions of each vertebra independently throughout the entire sequence. To validate the technique, 6 cadaveric lumbar spine specimens were potted in polymethylmethacrylate and instrumented with optoelectric sensors. The specimens were then placed in a custom dynamic spine simulator and moved through flexion-extension cycles while kinematic data and fluoroscopic sequences were simultaneously acquired. We found strong correlation between the absolute flexionextension range of motion of each vertebra as recorded by the optoelectric system and as determined from the fluoroscopic sequence via registration. We conclude that this method is a viable way of noninvasively assessing twodimensional vertebral motion.
Hong, Seong Sook; Kim, Ah Young; Kwon, Seok Beom; Kim, Pyo Nyun; Lee, Moon-Gyu; Ha, Hyun Kwon
2010-10-01
To evaluate the feasibility of 3D CT enterography using oral gastrografin in patients with small bowel obstruction (SBO), focusing on improving diagnostic performance as compared with the use of axial CT imagings and fluoroscopic findings. For a 10-month period, 18 patients with known SBO detected clinically and radiologically were enrolled. In all patients, gastrografin was ingested prior to CT enterography. Twelve patients underwent a fluoroscopic examination. Images were randomly assessed for confidence for the level, for the cause of SBO, and for the assessment of the interpretability of each image by two gastrointestinal radiologists. The results were considered statistically significant using the Wilcoxon rank sum test. All patients (100%) well tolerated the administration of oral gastrografin. The use of 3D CT enterography significantly improved diagnostic confidence for the interpretation of the level, cause of SBO, and the assessment of the interpretability of each image as compared with the use of axial CT images (P < 0.05). 3D CT enterography was superior as compared to fluoroscopic examination (P < 0.05). The use of gastrografin for 3D CT enterography is a safe and feasible technique for precise evaluation of known or suspected SBO.
Resnick, Daniel K
2003-06-01
Fluoroscopy-based frameless stereotactic systems provide feedback to the surgeon using virtual fluoroscopic images. The real-life accuracy of these virtual images has not been compared with traditional fluoroscopy in a clinical setting. We prospectively studied 23 consecutive cases. In two cases, registration errors precluded the use of virtual fluoroscopy. Pedicle probes placed with virtual fluoroscopic imaging were imaged with traditional fluoroscopy in the remaining 21 cases. Position of the probes was judged to be ideal, acceptable but not ideal, or not acceptable based on the traditional fluoroscopic images. Virtual fluoroscopy was used to place probes in for 97 pedicles from L1 to the sacrum. Eighty-eight probes were judged to be in ideal position, eight were judged to be acceptable but not ideal, and one probe was judged to be in an unacceptable position. This probe was angled toward an adjacent disc space. Therefore, 96 of 97 probes placed using virtual fluoroscopy were found to be in an acceptable position. The positive predictive value for acceptable screw placement with virtual fluoroscopy compared with traditional fluoroscopy was 99%. A probe placed with virtual fluoroscopic guidance will be judged to be in an acceptable position when imaged with traditional fluoroscopy 99% of the time.
Yang, Chi-Lin; Yang, Been-Der; Lin, Mu-Lien; Wang, Yao-Hung; Wang, Jaw-Lin
2010-10-01
Development of a patient-mount navigated intervention (PaMNI) system for spinal diseases. An in vivo clinical human trial was conducted to validate this system. To verify the feasibility of the PaMNI system with the clinical trial on percutaneous pulsed radiofrequency stimulation of dorsal root ganglion (PRF-DRG). Two major image guiding techniques, i.e., computed tomography (CT)-guided and fluoro-guided, were used for spinal intervention. The CT-guided technique provides high spatial resolution, and is claimed to be more accurate than the fluoro-guided technique. Nevertheless, the CT-guided intervention usually reaches higher radiograph exposure than the fluoro-guided counterpart. Some navigated intervention systems were developed to reduce the radiation of CT-guided intervention. Nevertheless, these systems were not popularly used due to the longer operation time, a new protocol for surgeons, and the availability of such a system. The PaMNI system includes 3 components, i.e., a patient-mount miniature tracking unit, an auto-registered reference frame unit, and a user-friendly image processing unit. The PRF-DRG treatment was conducted to find the clinical feasibility of this system. The in vivo clinical trial showed that the accuracy, visual analog scale evaluation after surgery, and radiograph exposure of the PaMNI-guided technique are comparable to the one of conventional fluoro-guided technique, while the operation time is increased by 5 minutes. Combining the virtues of fluoroscopy and CT-guided techniques, our navigation system is operated like a virtual fluoroscopy with augmented CT images. This system elevates the performance of CT-guided intervention and reduces surgeons' radiation exposure risk to a minimum, while keeping low radiation dose to patients like its fluoro-guided counterpart. The clinical trial of PRF-DRG treatment showed the clinical feasibility and efficacy of this system.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ma Yingliang; Housden, R. James; Razavi, Reza
2013-07-15
Purpose: X-ray fluoroscopically guided cardiac electrophysiology (EP) procedures are commonly carried out to treat patients with arrhythmias. X-ray images have poor soft tissue contrast and, for this reason, overlay of a three-dimensional (3D) roadmap derived from preprocedural volumetric images can be used to add anatomical information. It is useful to know the position of the catheter electrodes relative to the cardiac anatomy, for example, to record ablation therapy locations during atrial fibrillation therapy. Also, the electrode positions of the coronary sinus (CS) catheter or lasso catheter can be used for road map motion correction.Methods: In this paper, the authors presentmore » a novel unified computational framework for image-based catheter detection and tracking without any user interaction. The proposed framework includes fast blob detection, shape-constrained searching and model-based detection. In addition, catheter tracking methods were designed based on the customized catheter models input from the detection method. Three real-time detection and tracking methods are derived from the computational framework to detect or track the three most common types of catheters in EP procedures: the ablation catheter, the CS catheter, and the lasso catheter. Since the proposed methods use the same blob detection method to extract key information from x-ray images, the ablation, CS, and lasso catheters can be detected and tracked simultaneously in real-time.Results: The catheter detection methods were tested on 105 different clinical fluoroscopy sequences taken from 31 clinical procedures. Two-dimensional (2D) detection errors of 0.50 {+-} 0.29, 0.92 {+-} 0.61, and 0.63 {+-} 0.45 mm as well as success rates of 99.4%, 97.2%, and 88.9% were achieved for the CS catheter, ablation catheter, and lasso catheter, respectively. With the tracking method, accuracies were increased to 0.45 {+-} 0.28, 0.64 {+-} 0.37, and 0.53 {+-} 0.38 mm and success rates increased to 100%, 99.2%, and 96.5% for the CS, ablation, and lasso catheters, respectively. Subjective clinical evaluation by three experienced electrophysiologists showed that the detection and tracking results were clinically acceptable.Conclusions: The proposed detection and tracking methods are automatic and can detect and track CS, ablation, and lasso catheters simultaneously and in real-time. The accuracy of the proposed methods is sub-mm and the methods are robust toward low-dose x-ray fluoroscopic images, which are mainly used during EP procedures to maintain low radiation dose.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
McCabe, Bradley P.; Speidel, Michael A.; Pike, Tina L.
Purpose: In this study, newly formulated XR-RV3 GafChromic film was calibrated with National Institute of Standards and Technology (NIST) traceability for measurement of patient skin dose during fluoroscopically guided interventional procedures. Methods: The film was calibrated free-in-air to air kerma levels between 15 and 1100 cGy using four moderately filtered x-ray beam qualities (60, 80, 100, and 120 kVp). The calibration films were scanned with a commercial flatbed document scanner. Film reflective density-to-air kerma calibration curves were constructed for each beam quality, with both the orange and white sides facing the x-ray source. A method to correct for nonuniformity inmore » scanner response (up to 25% depending on position) was developed to enable dose measurement with large films. The response of XR-RV3 film under patient backscattering conditions was examined using on-phantom film exposures and Monte Carlo simulations. Results: The response of XR-RV3 film to a given air kerma depended on kVp and film orientation. For a 200 cGy air kerma exposure with the orange side of the film facing the source, the film response increased by 20% from 60 to 120 kVp. At 500 cGy, the increase was 12%. When 500 cGy exposures were performed with the white side facing the x-ray source, the film response increased by 4.0% (60 kVp) to 9.9% (120 kVp) compared to the orange-facing orientation. On-phantom film measurements and Monte Carlo simulations show that using a NIST-traceable free-in-air calibration curve to determine air kerma in the presence of backscatter results in an error from 2% up to 8% depending on beam quality. The combined uncertainty in the air kerma measurement from the calibration curves and scanner nonuniformity correction was {+-}7.1% (95% C.I.). The film showed notable stability. Calibrations of film and scanner separated by 1 yr differed by 1.0%. Conclusions: XR-RV3 radiochromic film response to a given air kerma shows dependence on beam quality and film orientation. The presence of backscatter slightly modifies the x-ray energy spectrum; however, the increase in film response can be attributed primarily to the increase in total photon fluence at the sensitive layer. Film calibration curves created under free-in-air conditions may be used to measure dose from fluoroscopic quality x-ray beams, including patient backscatter with an error less than the uncertainty of the calibration in most cases.« less
McCabe, Bradley P; Speidel, Michael A; Pike, Tina L; Van Lysel, Michael S
2011-04-01
In this study, newly formulated XR-RV3 GafChromic film was calibrated with National Institute of Standards and Technology (NIST) traceability for measurement of patient skin dose during fluoroscopically guided interventional procedures. The film was calibrated free-in-air to air kerma levels between 15 and 1100 cGy using four moderately filtered x-ray beam qualities (60, 80, 100, and 120 kVp). The calibration films were scanned with a commercial flatbed document scanner. Film reflective density-to-air kerma calibration curves were constructed for each beam quality, with both the orange and white sides facing the x-ray source. A method to correct for nonuniformity in scanner response (up to 25% depending on position) was developed to enable dose measurement with large films. The response of XR-RV3 film under patient backscattering conditions was examined using on-phantom film exposures and Monte Carlo simulations. The response of XR-RV3 film to a given air kerma depended on kVp and film orientation. For a 200 cGy air kerma exposure with the orange side of the film facing the source, the film response increased by 20% from 60 to 120 kVp. At 500 cGy, the increase was 12%. When 500 cGy exposures were performed with the white side facing the x-ray source, the film response increased by 4.0% (60 kVp) to 9.9% (120 kVp) compared to the orange-facing orientation. On-phantom film measurements and Monte Carlo simulations show that using a NIST-traceable free-in-air calibration curve to determine air kerma in the presence of backscatter results in an error from 2% up to 8% depending on beam quality. The combined uncertainty in the air kerma measurement from the calibration curves and scanner nonuniformity correction was +/- 7.1% (95% C.I.). The film showed notable stability. Calibrations of film and scanner separated by 1 yr differed by 1.0%. XR-RV3 radiochromic film response to a given air kerma shows dependence on beam quality and film orientation. The presence of backscatter slightly modifies the x-ray energy spectrum; however, the increase in film response can be attributed primarily to the increase in total photon fluence at the sensitive layer. Film calibration curves created under free-in-air conditions may be used to measure dose from fluoroscopic quality x-ray beams, including patient backscatter with an error less than the uncertainty of the calibration in most cases.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vijayan, S; Xiong, Z; Rudin, S
Purpose: The functionality of the Dose-Tracking System (DTS) has been expanded to include the calculation of the Kerma-Area Product (KAP) for non-uniform x-ray fields such as result from the use of compensation filters during fluoroscopic procedures Methods: The DTS calculates skin dose during fluoroscopic interventions and provides a color-coded dose map on a patient-graphic model. The KAP is the integral of air kerma over the x-ray field and is usually measured with a transmission-ionization chamber that intercepts the entire x-ray beam. The DTS has been modified to determine KAP when there are beam non-uniformities that can be modeled. For example,more » the DTS includes models of the three compensation filters with tapered edges located in the collimator assembly of the Toshiba Infinix fluoroscopic C-Arm and can track their movement. To determine the air kerma after the filters, DTS includes transmission factors for the compensation filters as a function of kVp and beam filtration. A virtual KAP dosimeter is simulated in the DTS by an array of graphic vertices; the air kerma at each vertex is corrected by the field non-uniformity, which in this case is the attenuation factor for those rays which pass through the filter. The products of individual vertex air-kerma values for all vertices within the beam times the effective-area-per-vertex are summed for each x-ray pulse to yield the KAP per pulse and the cumulative KAP for the procedure is then calculated. Results: The KAP values estimated by DTS with the compensation filter inserted into the x-ray field agree within ± 6% with the values displayed on the fluoroscopy unit monitor, which are measured with a transmission chamber. Conclusion: The DTS can account for field non-uniformities such as result from the use of compensation filters in calculating KAP and can obviate the need for a KAP transmission ionization chamber. Partial support from NIH Grant R01-EB002873 and Toshiba Medical Systems Corp.« less
Motomura, Yasuaki; Akahoshi, Kazuya; Gibo, Junya; Kanayama, Kenji; Fukuda, Shinichiro; Hamada, Shouhei; Otsuka, Yoshihiro; Kubokawa, Masaru; Kajiyama, Kiyoshi; Nakamura, Kazuhiko
2014-01-01
AIM: To investigate the causes and intraoperative detection of endoscopic retrograde cholangiopancreatography (ERCP)-related perforations to support immediate or early diagnosis. METHODS: Consecutive patients who underwent ERCP procedures at our hospital between January 2008 and June 2013 were retrospectively enrolled in the study (n = 2674). All procedures had been carried out using digital fluoroscopic assistance with the patient under conscious sedation. For patients showing alterations in the gastrointestinal anatomy, a short-type double balloon enteroscope had been applied. Cases of perforation had been identified by the presence of air in or leakage of contrast medium into the retroperitoneal space, or upon endoscopic detection of an abdominal cavity related to the perforated lumen. For patients with ERCP-related perforations, the data on medical history, endoscopic findings, radiologic findings, diagnostic methods, management, and clinical outcomes were used for descriptive analysis. RESULTS: Of the 2674 ERCP procedures performed during the 71-mo study period, only six (0.22%) resulted in perforations (male/female, 2/4; median age: 84 years; age range: 57-97 years). The cases included an endoscope-related duodenal perforation, two periampullary perforations related to endoscopic sphincterotomy, two periampullary perforations related to endoscopic papillary balloon dilation, and a periampullary or bile duct perforation secondary to endoscopic instrument trauma. No cases of guidewire-related perforation occurred. The video endoscope system employed in all procedures was only able to immediately detect the endoscope-related perforation; the other five perforation cases were all detected by subsequent digital fluoroscope applied intraoperatively (at a median post-ERCP intervention time of 15 min). Three out of the six total perforation cases, including the single case of endoscope-related duodenal injury, were surgically treated; the remaining three cases were treated with conservative management, including trans-arterial embolization to control the bleeding in one of the cases. All patients recovered without further incident. CONCLUSION: ERCP-related perforations may be difficult to diagnose by video endoscope and digital fluoroscope detection of retroperitoneal free air or contrast medium leakage can facilitate diagnosis. PMID:25400465
Mulvaney, Sean W
2009-01-01
Viscosupplementation of the hip for symptomatic osteoarthritis appears to be safe and effective in more than 25 yr of use in Europe. More than 11 studies suggest that viscosupplementation in the hip is as effective as viscosupplementation in the knee. It appears to be a safe and reasonable alternative to nonsteroidal antiinflammatory drugs or intra-articular steroids for the treatment of osteoarthritis pain. Viscosupplementation in the hip may delay the need for hip replacement surgery. Viscosupplementation in the hip appears to work better in patients with fewer radiographic changes of osteoarthritis. Placement of viscosupplement in the hip under real-time ultrasound or fluoroscopic guidance is safe and well tolerated. Hip joint communication with the iliopsoas bursa may be a factor in studies of the effectiveness of viscosupplementation in the hip.
History and Evolution of the Barium Swallow for Evaluation of the Pharynx and Esophagus.
Levine, Marc S; Rubesin, Stephen E
2017-02-01
This article reviews the history of the barium swallow from its early role in radiology to its current status as an important diagnostic test in modern radiology practice. Though a variety of diagnostic procedures can be performed to evaluate patients with dysphagia or other pharyngeal or esophageal symptoms, the barium study has evolved into a readily available, non-invasive, and cost-effective technique that can facilitate the selection of additional diagnostic tests and guide decisions about medical, endoscopic, or surgical management. This article focuses on the evolution of fluoroscopic equipment, radiography, and contrast media for evaluating the pharynx and esophagus, the importance of understanding pharyngoesophageal relationships, and major advances that have occurred in the radiologic diagnosis of select esophageal diseases, including gastroesophageal reflux disease, infectious esophagitis, eosinophilic esophagitis, esophageal carcinoma, and esophageal motility disorders.
Guided Imagery as a Treatment Option for Fatigue
Menzies, Victoria; Jallo, Nancy
2013-01-01
Purpose Fatigue is one of the most common complaints experienced among the general population. Because fatigue is recognized as a biobehavioral occurrence, a biobehavioral intervention such as guided imagery may be effective in reducing self-reported fatigue. Therefore, the purpose of this study was to explore the research literature related to the use of guided imagery as a nonpharmacological mind-body intervention for the symptom of fatigue. Method The electronic databases MEDLINE, CINAHL, PsychInfo, Psychology and Behavioral Sciences Collection and the Cochrane Library were searched from January 1980 to June 2010. Findings Of 24 articles retrieved, eight met the inclusion criteria and were included in this systematic literature review. Findings were inconsistent regarding the effectiveness of guided imagery on fatigue. Studies varied in study length, duration of the applied guided imagery intervention, dosage, and whether the images were targeted to the purpose of the intervention. Implications Guided imagery is a simple, economic intervention with the potential to effectively treat fatigue, thus further research is warranted using systematic, well-designed methodologies Standardizing guided imagery interventions according to total duration of exposure and targeted imagery in a variety of different populations adequately powered to detect changes will contribute to and strengthen nursing’s symptom-management armamentarium. PMID:21772047
SU-E-J-56: Static Gantry Digital Tomosynthesis From the Beam’s-Eye-View
DOE Office of Scientific and Technical Information (OSTI.GOV)
Partain, L; Kwon, J; Boyd, D
Purpose We have designed a novel TumoTrak™ x-ray system that delivers 19 distinct kV views with the linac gantry stationary. It images MV treatment beam above and below the patient with a kV tomosysthesis slice image from the therapy beam’s-eye-view. Results will be high quality images without MLC shadowing for notable improvements relative to conventional fluoroscopic MV imaging and fluoroscopic kV imaging. Methods A complete design has a kV electron beam multisource X-ray tube that fits around the MV treatment beam path, with little interference with normal radiotherapy and unblocked by the multi-leaf-collimator. To simulate digital tomosynthesis, we used cone-beammore » CT projection data from a lung SBRT patient. These data were acquired at 125 kVp and 11 fps (0.4 mAs per projection). We chose 19 projections evenly spaced over 27° around one of the treatment angles (240°). Digital tomosynthesis reconstruction of a slice through the tumor was performed using iterative reconstruction. The visibility of the lesion was assessed for the reconstructed digital tomosynthesis (DTS), using fluoroscopy MV images acquired during radiation therapy, and a kV single projection image acquired at the same angle as the treatment field (240°). Results The fluoroscopic DTS images provide the best tumor contrast, surpassing the conventional radiographic and the in-treatment MV portal images. The electron beam multisource X-ray tube design has been completed and the tube is being fabricated. The estimated time to cycle through all 19 projections is 700 ms, enabling high frame-rate imaging. While the initial proposed use case is for image guided and gated treatment delivery, the enhanced imaging will also deliver superior radiographic images for patient setup. Conclusion The proposed device will deliver high quality planar images from the beam’s-eye-view without MLC obstruction. The prototype has been designed and is being assembled with first imaging scheduled for May 2015. L. Partain, J. Kwon, D. Boyd: NIH/SBIR R43CA192489-01. J. Rottmann, G. Zentai, R. Berbeco: NIH/NCI 1R01CA188446-01. R. Berbeco: E. Research Grant, Varian Medical Systems.« less
Wolfschmidt, Franziska; Hassold, Nicole; Goltz, Jan Peter; Leyh, Rainer; Bley, Thorsten Alexander; Kickuth, Ralph
2015-09-01
To evaluate the feasibility, effectiveness, and safety of using a commercially available reentry catheter with fluoroscopic guidance to gain controlled target lumen reentry for fenestration in patients with aortic dissection. This retrospective study was approved by the local institutional review board; informed consent was waived. Between April 2009 and December 2013, 13 consecutive patients (10 men and three women; mean age, 51.2 years; range, 30.0-77.0 years; mean age of women, 47.0 years; range, 30.0-69.0 years; mean age of men, 52.4 years; range, 35.0-77.0 years) with aortic dissection and spinal (n = 4), renal (n = 7), mesenteric (n = 2), and/or iliofemoral (n = 9) malperfusion syndrome were included. All patients received target lumen reentry by means of balloon fenestration of the aortic dissection flap. A reentry catheter was used for fluoroscopically guided puncture of the target lumen. Technical success, clinical outcome, Stanford type of dissection, procedure time, number of fenestrations of the intimal flap per patient, necessity of additional aortic stent-graft implantation and/or placement of a bare metal stent, complications, and follow-up images were evaluated. Pre- and postinterventional systolic blood pressure gradients between the true lumen and the false lumen were compared (Wilcoxon signed-rank test). Safety of the reentry catheter maneuver was estimated with the Clopper-Pearson method. Use of the reentry catheter was technically successful in all 13 (100%) patients and clinically successful in 10 of 13 (77%) patients. Four patients had type A and nine had type B dissection. The mean clinical follow-up period was 14.2 months. Median procedure time was 71 minutes. In four patients, fenestration of the intimal flap was performed twice. Three patients underwent additional aortic stent grafting, four patients underwent placement of an iliofemoral stent, and one patient underwent placement of a carotid artery stent. Blood pressure gradients between the true lumen and the false lumen were significantly reduced (P = .0313). One patient who had a combination of syndromes died of multiorgan failure. The applied commercially available reentry catheter seems to be a reliable and safe tool that may be useful for gaining target lumen reentry with reasonably good clinical outcomes.
Electromagnetic navigation diagnostic bronchoscopy for small peripheral lung lesions.
Makris, D; Scherpereel, A; Leroy, S; Bouchindhomme, B; Faivre, J-B; Remy, J; Ramon, P; Marquette, C-H
2007-06-01
The present study prospectively evaluated the diagnostic yield and safety of electromagnetic navigation-guided bronchoscopy biopsy, for small peripheral lung lesions in patients where standard techniques were nondiagnostic. The study was conducted in a tertiary medical centre on 40 consecutive patients considered unsuitable for straightforward surgery or computed tomography (CT)-guided transthoracic needle aspiration biopsy, due to comorbidities. The lung lesion diameter was mean+/-sem 23.5+/-1.5 mm and the depth from the visceral-costal pleura was 14.9+/-2 mm. Navigation was facilitated by an electromagnetic tracking system which could detect a position sensor incorporated into a flexible catheter advanced through a bronchoscope. Information obtained during bronchoscopy was superimposed on previously acquired CT data. Divergence between CT data and data obtained during bronchoscopy was calculated by the system's software as a measure of navigational accuracy. All but one of the target lesions was reached and the overall diagnostic yield was 62.5% (25-40). Diagnostic yield was significantly affected by CT-to-body divergence; yield was 77.2% when estimated divergence was
The capability of fluoroscopic systems to determine differential Roentgen-ray absorption
NASA Technical Reports Server (NTRS)
Baily, N. A.; Crepeau, R. L.
1975-01-01
A clinical fluoroscopic unit used in conjunction with a TV image digitization system was investigated to determine its capability to evaluate differential absorption between two areas in the same field. Fractional contrasts and minimum detectability for air, several concentrations of Renografin-60, and aluminum were studied using phantoms of various thicknesses. Results showed that the videometric response, when treated as contrast, shows a linear response with absorber thickness up to considerable thicknesses.
Sarkar, V; Gutierrez, A N; Stathakis, S; Swanson, G P; Papanikolaou, N
2009-01-01
The purpose of this project was to develop a software platform to produce a virtual fluoroscopic image as an aid for permanent prostate seed implants. Seed location information from a pre-plan was extracted and used as input to in-house developed software to produce a virtual fluoroscopic image. In order to account for differences in patient positioning on the day of treatment, the user was given the ability to make changes to the virtual image. The system has been shown to work as expected for all test cases. The system allows for quick (on average less than 10 sec) generation of a virtual fluoroscopic image of the planned seed pattern. The image can be used as a verification tool to aid the physician in evaluating how close the implant is to the planned distribution throughout the procedure and enable remedial action should a large deviation be observed.
de Freitas, Ricardo Miguel Costa; Andrade, Celi Santos; Caldas, José Guilherme Mendes Pereira; Tsunemi, Miriam Harumi; Ferreira, Lorraine Braga; Arana-Chavez, Victor Elias; Cury, Patrícia Maluf
2015-10-01
This study was designed to present the feasibility of an in vivo image-guided percutaneous cryoablation of the porcine vertebral body. The institutional animal care committee approved this study. Cone-beam computed tomography (CBCT)-guided vertebral cryoablations (n = 22) were performed in eight pigs with short, 2-min, single or double-freezing protocols. Protective measures to nerves included dioxide carbon (CO2) epidural injections and spinal canal temperature monitoring. Clinical, radiological, and pathological data with light (n = 20) or transmission electron (n = 2) microscopic analyses were evaluated after 6 days of clinical follow-up and euthanasia. CBCT/fluoroscopic-guided transpedicular vertebral body cryoprobe positioning and CO2 epidural injection were successful in all procedures. No major complications were observed in seven animals (87.5 %, n = 8). A minor complication was observed in one pig (12.5 %, n = 1). Logistic regression model analysis showed the cryoprobe-spinal canal (Cp-Sc) distance as the most efficient parameter to categorize spinal canal temperatures lower than 19 °C (p < 0.004), with a significant Pearson's correlation test (p < 0.041) between the Cp-Sc distance and the lowest spinal canal temperatures. Ablation zones encompassed pedicles and the posterior wall of the vertebral bodies with an inflammatory rim, although no inflammatory infiltrate was depicted in the surrounding neural structures at light microscopy. Ultrastructural analyses evidenced myelin sheath disruption in some large nerve fibers, although neurological deficits were not observed. CBCT-guided vertebral cryoablation of the porcine spine is feasible under a combination of a short freezing protocol and protective measures to the surrounding nerves. Ultrastructural analyses may be helpful assess the early modifications of the nerve fibers.
Devito, Dennis P; Kaplan, Leon; Dietl, Rupert; Pfeiffer, Michael; Horne, Dale; Silberstein, Boris; Hardenbrook, Mitchell; Kiriyanthan, George; Barzilay, Yair; Bruskin, Alexander; Sackerer, Dieter; Alexandrovsky, Vitali; Stüer, Carsten; Burger, Ralf; Maeurer, Johannes; Donald, Gordon D; Gordon, Donald G; Schoenmayr, Robert; Friedlander, Alon; Knoller, Nachshon; Schmieder, Kirsten; Pechlivanis, Ioannis; Kim, In-Se; Meyer, Bernhard; Shoham, Moshe
2010-11-15
Retrospective, multicenter study of robotically-guided spinal implant insertions. Clinical acceptance of the implants was assessed by intraoperative radiograph, and when available, postoperative computed tomography (CT) scans were used to determine placement accuracy. To verify the clinical acceptance and accuracy of robotically-guided spinal implants and compare to those of unguided free-hand procedures. SpineAssist surgical robot has been used to guide implants and guide-wires to predefined locations in the spine. SpineAssist which, to the best of the authors' knowledge, is currently the sole robot providing surgical assistance in positioning tools in the spine, guided over 840 cases in 14 hospitals, between June 2005 and June 2009. Clinical acceptance of 3271 pedicle screws and guide-wires inserted in 635 reported cases was assessed by intraoperative fluoroscopy, where placement accuracy of 646 pedicle screws inserted in 139 patients was measured using postoperative CT scans. Screw placements were found to be clinically acceptable in 98% of the cases when intraoperatively assessed by fluoroscopic images. Measurements derived from postoperative CT scans demonstrated that 98.3% of the screws fell within the safe zone, where 89.3% were completely within the pedicle and 9% breached the pedicle by up to 2 mm. The remaining 1.4% of the screws breached between 2 and 4 mm, while only 2 screws (0.3%) deviated by more than 4 mm from the pedicle wall. Neurologic deficits were observed in 4 cases yet, following revisions, no permanent nerve damage was encountered, in contrast to the 0.6% to 5% of neurologic damage reported in the literature. SpineAssist offers enhanced performance in spinal surgery when compared to free-hand surgeries, by increasing placement accuracy and reducing neurologic risks. In addition, 49% of the cases reported herein used a percutaneous approach, highlighting the contribution of SpineAssist in procedures without anatomic landmarks.
Skin dose mapping for fluoroscopically guided interventions.
Johnson, Perry B; Borrego, David; Balter, Stephen; Johnson, Kevin; Siragusa, Daniel; Bolch, Wesley E
2011-10-01
To introduce a new skin dose mapping software system for interventional fluoroscopy dose assessment and to analyze the benefits and limitations of patient-phantom matching. In this study, a new software system was developed for visualizing patient skin dose during interventional fluoroscopy procedures. The system works by translating the reference point air kerma to the location of the patient's skin, which is represented by a computational model. In order to orient the model with the x-ray source, geometric parameters found within the radiation dose structured report (RDSR) are used along with a limited number of in-clinic measurements. The output of the system is a visual indication of skin dose mapped onto an anthropomorphic model at a resolution of 5 mm. In order to determine if patient-dependent and patient-sculpted models increase accuracy, peak skin dose was calculated for each of 26 patient-specific models and compared with doses calculated using an elliptical stylized model, a reference hybrid model, a matched patient-dependent model and one patient-sculpted model. Results were analyzed in terms of a percent difference using the doses calculated using the patient-specific model as the true standard. Anthropometric matching, including the use of both patient-dependent and patient-sculpted phantoms, was shown most beneficial for left lateral and anterior-posterior projections. In these cases, the percent difference using a reference model was between 8 and 20%, using a patient-dependent model between 7 and 15%, and using a patient-sculpted model between 3 and 7%. Under the table tube configurations produced errors less than 5% in most situations due to the flattening affects of the table and pad, and the fact that table height is the main determination of source-to-skin distance for these configurations. In addition to these results, several skin dose maps were produced and a prototype display system was placed on the in-clinic monitor of an interventional fluoroscopy system. The skin dose mapping program developed in this work represents a new tool that, as the RDSR becomes available through automated export or real-time streaming, can provide the interventional physician information needed to modify behavior when clinically appropriate. The program is nonproprietary and transferable, and also functions independent to the software systems already installed on the control room workstation. The next step will be clinical implementation where the workflow will be optimized along with further analysis of real-time capabilities.
Labibzadeh, Narges; Emadedin, Mohsen; Fazeli, Roghayeh; Mohseni, Fatemeh; Hosseini, Seyedeh Esmat; Moghadasali, Reza; Mardpour, Soura; Azimian, Vajiheh; Ghorbani Liastani, Maede; Mirazimi Bafghi, Ali; Baghaban Eslaminejad, Mohamadreza; Aghdami, Nasser
2016-01-01
Nonunion is defined as a minimum of 9 months since injury without any visible progressive signs of healing for 3 months. Recent literature has shown that the application of mesenchymal stromal cells is safe, in vitro and in vivo, for treating long bone nonunion. The present study was performed to investigate the safety of mesenchymal stromal cell (MSC) implantation in combination with platelet lysate (PL) product for treating human long bone nonunion. In this case series clinical trial, orthopedic surgeons visited eighteen patients with long bone nonunion, of whom 7 complied with the eligibility criteria. These patients received mesenchymal stromal cells (20 million cells implanted once into the nonunion site using a fluoroscopic guide) in combination with PL product. For evaluation of the effects of this intervention all the patients were followed up by taking anterior-posterior and lateral X-rays of the affected limb before and 1, 3, 6, and 12 months after the implantation. All side effects (local or systemic, serious or non-serious, related or unrelated) were observed during this time period. From a safety perspective the MSC implantation in combination with PL was very well tolerated during the 12 months of the trial. Four patients were healed; based on the control Xray evidence, bony union had occurred. Results from the present study suggest that the implantation of bone marrow-derived MSCs in combination with PL is safe for the treatment of nonunion. A double blind, controlled clinical trial is required to assess the efficacy of this treatment (Registration Number: NCT01206179).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Culp, William C., E-mail: culpwilliamc@uams.edu; McCowan, Timothy C.; DeValdenebro, Miguel
Background and Purpose. Percutaneous transhepatic biliary drainage remains a painful procedure in many cases despite the routine use of large amounts of intravenous sedation. We present a feasibility study of thoracic paravertebral blocks in an effort to reduce pain during and following the procedure and reduce requirements for intravenous sedation. Methods. Ten consecutive patients undergoing biliary drainage procedures received fluoroscopically guided paravertebral blocks and then had supplemental intravenous sedation as required to maintain patient comfort. Levels T8-T9 and T9-T10 on the right were targeted with 10-20 ml of 0.5% bupivacaine. Sedation requirements and pain levels were recorded. Results. Ten biliarymore » drainage procedures in 8 patients were performed for malignancy in 8 cases and for stones in 2. The mean midazolam use was 1.13 mg IV, and the mean fentanyl requirement was 60.0 {mu}g IV in the block patients. Two episodes of hypotension, which responded promptly to volume replacement, may have been related to the block. No serious complications were encountered. The mean pain score when traversing the chest wall, liver capsule, and upon entering the bile ducts was 0.1 on a scale of 0 to 10, with 1 patient reporting a pain level of 1 and 9 reporting 0. The mean peak pain score, encountered when manipulating at the common bile duct level or when addressing stones there, was 5.4 and ranged from 0 to 10. Conclusions. Thoracic paravertebral block with intravenous sedation supplementation appears to be a feasible method of pain control during biliary interventions.« less
TU-F-201-00: Radiochromic Film Dosimetry Update
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
Since the introduction of radiochromic films (RCF) for radiation dosimetry, the scope of RCF dosimetry has expanded steadily to include many medical applications, such as radiation therapy and diagnostic radiology. The AAPM Task Group (TG) 55 published a report on the recommendations for RCF dosimetry in 1998. As the technology is advancing rapidly, and its routine clinical use is expanding, TG 235 has been formed to provide an update to TG-55 on radiochromic film dosimetry. RCF dosimetry applications in clinical radiotherapy have become even more widespread, expanding from primarily brachytherapy and radiosurgery applications, and gravitating towards (but not limited to)more » external beam therapy (photon, electron and protons), such as quality assurance for IMRT, VMAT, Tomotherapy, SRS/SRT, and SBRT. In addition, RCF applications now extend to measurements of radiation dose in particle beams and patients undergoing medical exams, especially fluoroscopically guided interventional procedures and CT. The densitometers/scanners used for RCF dosimetry have also evolved from the He-Ne laser scanner to CCD-based scanners, including roller-based scanner, light box-based digital camera, and flatbed color scanner. More recently, multichannel RCF dosimetry introduced a new paradigm for external beam dose QA for its high accuracy and efficiency. This course covers in detail the recent advancements in RCF dosimetry. Learning Objectives: Introduce the paradigm shift on multichannel film dosimetry Outline the procedures to achieve accurate dosimetry with a RCF dosimetry system Provide comprehensive guidelines on RCF dosimetry for various clinical applications One of the speakers has a research agreement from Ashland Inc., the manufacturer of Gafchromic film.« less
TU-F-201-01: General Aspects of Radiochromic Film Dosimetry
DOE Office of Scientific and Technical Information (OSTI.GOV)
Niroomand-Rad, A.
Since the introduction of radiochromic films (RCF) for radiation dosimetry, the scope of RCF dosimetry has expanded steadily to include many medical applications, such as radiation therapy and diagnostic radiology. The AAPM Task Group (TG) 55 published a report on the recommendations for RCF dosimetry in 1998. As the technology is advancing rapidly, and its routine clinical use is expanding, TG 235 has been formed to provide an update to TG-55 on radiochromic film dosimetry. RCF dosimetry applications in clinical radiotherapy have become even more widespread, expanding from primarily brachytherapy and radiosurgery applications, and gravitating towards (but not limited to)more » external beam therapy (photon, electron and protons), such as quality assurance for IMRT, VMAT, Tomotherapy, SRS/SRT, and SBRT. In addition, RCF applications now extend to measurements of radiation dose in particle beams and patients undergoing medical exams, especially fluoroscopically guided interventional procedures and CT. The densitometers/scanners used for RCF dosimetry have also evolved from the He-Ne laser scanner to CCD-based scanners, including roller-based scanner, light box-based digital camera, and flatbed color scanner. More recently, multichannel RCF dosimetry introduced a new paradigm for external beam dose QA for its high accuracy and efficiency. This course covers in detail the recent advancements in RCF dosimetry. Learning Objectives: Introduce the paradigm shift on multichannel film dosimetry Outline the procedures to achieve accurate dosimetry with a RCF dosimetry system Provide comprehensive guidelines on RCF dosimetry for various clinical applications One of the speakers has a research agreement from Ashland Inc., the manufacturer of Gafchromic film.« less
NASA Astrophysics Data System (ADS)
Chandler, John E.; Melville, C. David; Lee, Cameron M.; Saunders, Michael D.; Burkhardt, Matthew R.; Seibel, Eric J.
2011-03-01
Endoscopic investigation of the main pancreatic duct and biliary ducts is called endoscopic retrograde cholangiopancreatography (ERCP), and carries a risk of pancreatitis for the patient. During ERCP, a metal guidewire is inserted into the pancreatobiliary duct from a side-viewing large endoscope within the duodenum. To verify correct placement of the ERCP guidewire, an injection of radiopaque dye is required for fluoroscopic imaging, which exposes the patient and clinical team to x-ray radiation. A safer and more effective means to access the pancreatobiliary system can use direct optical imaging, although the endoscope diameter and stiffness will be significantly larger than a guidewire's. To quantify this invasiveness before human testing, a synthetic force-sensing pancreas was fabricated and attached to an ERCP training model. The invasiveness of a new, 1.7-mm diameter, steerable scanning fiber endoscope (SFE) was compared to the standard ERCP guidewire of 0.89-mm (0.035") diameter that is not steerable. Although twice as large and significantly stiffer than the ERCP guidewire, the SFE generated lower or significantly less average force during insertion at all 4 sensor locations (P<0.05) within the main pancreatic duct. Therefore, the addition of steering and forward visualization at the tip of the endoscope reduced the invasiveness of the in vitro ERCP procedure. Since fluoroscopy is not required, risks associated with dye injection and x-ray exposure can be eliminated when using direct optical visualization. Finally, the SFE provides wide-field high resolution imaging for image-guided interventions, laser-based fluorescence biomarker imaging, and spot spectral analysis for future optical biopsy.
Clinical effectiveness of the obturator externus muscle injection in chronic pelvic pain patients.
Kim, Shin Hyung; Kim, Do Hyeong; Yoon, Duck Mi; Yoon, Kyung Bong
2015-01-01
Because of its anatomical location and function, the obturator externus (OE) muscle can be a source of pain; however, this muscle is understudied as a possible target for therapeutic intervention in pain practice. In this retrospective observational study, we evaluated the clinical effectiveness of the OE muscle injection with a local anesthetic in chronic pelvic pain patients with suspected OE muscle problems. Twenty-three patients with localized tenderness on the inferolateral side of the pubic tubercle accompanied by pain in the groin, anteromedial thigh, or hip were studied. After identifying the OE with contrast dye under fluoroscopic guidance, 5 to 8 mL of 0.3% lidocaine was injected. Pain scores were assessed before and after injection; patient satisfaction was also assessed. Mean pain score decreased by 44.7% (6.6 ± 1.8 to 3.5 ± 0.9, P < 0.001) 2 weeks after OE muscle injection as compared with pain score before injection. In addition, 82% of patients (19 of 23 patients) reported excellent or good satisfaction during 2 weeks after injection. No patients reported complications from OE muscle injection. Fluoroscopy-guided injection of the OE muscle with local anesthetic reduced pain scores and led to a high level of satisfaction at short-term follow-up in patients with suspected OE muscle problem. The results of this study suggest that OE muscle injection may be a valuable therapeutic option for a select group of chronic pelvic pain patients who present with localized tenderness in the OE muscle that is accompanied by groin, anteromedial thigh, or hip pain. © 2013 World Institute of Pain.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chiu-Tsao, S.
Since the introduction of radiochromic films (RCF) for radiation dosimetry, the scope of RCF dosimetry has expanded steadily to include many medical applications, such as radiation therapy and diagnostic radiology. The AAPM Task Group (TG) 55 published a report on the recommendations for RCF dosimetry in 1998. As the technology is advancing rapidly, and its routine clinical use is expanding, TG 235 has been formed to provide an update to TG-55 on radiochromic film dosimetry. RCF dosimetry applications in clinical radiotherapy have become even more widespread, expanding from primarily brachytherapy and radiosurgery applications, and gravitating towards (but not limited to)more » external beam therapy (photon, electron and protons), such as quality assurance for IMRT, VMAT, Tomotherapy, SRS/SRT, and SBRT. In addition, RCF applications now extend to measurements of radiation dose in particle beams and patients undergoing medical exams, especially fluoroscopically guided interventional procedures and CT. The densitometers/scanners used for RCF dosimetry have also evolved from the He-Ne laser scanner to CCD-based scanners, including roller-based scanner, light box-based digital camera, and flatbed color scanner. More recently, multichannel RCF dosimetry introduced a new paradigm for external beam dose QA for its high accuracy and efficiency. This course covers in detail the recent advancements in RCF dosimetry. Learning Objectives: Introduce the paradigm shift on multichannel film dosimetry Outline the procedures to achieve accurate dosimetry with a RCF dosimetry system Provide comprehensive guidelines on RCF dosimetry for various clinical applications One of the speakers has a research agreement from Ashland Inc., the manufacturer of Gafchromic film.« less
An Endovascular Approach to the Entrapped Central Venous Catheter After Cardiac Surgery
DOE Office of Scientific and Technical Information (OSTI.GOV)
Desai, Shamit S., E-mail: shamit.desai@northwestern.edu; Konanur, Meghana; Foltz, Gretchen
PurposeEntrapment of central venous catheters (CVC) at the superior vena cava (SVC) cardiopulmonary bypass cannulation site by closing purse-string sutures is a rare complication of cardiac surgery. Historically, resternotomy has been required for suture release. An endovascular catheter release approach was developed.Materials and MethodsFour cases of CVC tethering against the SVC wall and associated resistance to removal, suggestive of entrapment, were encountered. In each case, catheter removal was achieved using a reverse catheter fluoroscopically guided over the suture fixation point between catheter and SVC wall, followed by the placement of a guidewire through the catheter. The guidewire was snared andmore » externalized to create a through-and-through access with the apex of the loop around the suture. A snare placed from the femoral venous access provided concurrent downward traction on the distal CVC during suture release maneuvers.ResultsIn the initial attempt, gentle traction freed the CVC, which fractured and was removed in two sections. In the subsequent three cases, traction alone did not release the CVC. Therefore, a cutting balloon was introduced over the guidewire and inflated. Gentle back-and-forth motion of the cutting balloon atherotomes successfully incised the suture in all three attempts. No significant postprocedural complications were encountered. During all cases, a cardiovascular surgeon was present in the interventional suite and prepared for emergent resternotomy, if necessary.ConclusionAn endovascular algorithm to the “entrapped CVC” is proposed, which likely reduces risks posed by resternotomy to cardiac surgery patients in the post-operative period.« less
Graphical user interface for a dual-module EMCCD x-ray detector array
NASA Astrophysics Data System (ADS)
Wang, Weiyuan; Ionita, Ciprian; Kuhls-Gilcrist, Andrew; Huang, Ying; Qu, Bin; Gupta, Sandesh K.; Bednarek, Daniel R.; Rudin, Stephen
2011-03-01
A new Graphical User Interface (GUI) was developed using Laboratory Virtual Instrumentation Engineering Workbench (LabVIEW) for a high-resolution, high-sensitivity Solid State X-ray Image Intensifier (SSXII), which is a new x-ray detector for radiographic and fluoroscopic imaging, consisting of an array of Electron-Multiplying CCDs (EMCCDs) each having a variable on-chip electron-multiplication gain of up to 2000x to reduce the effect of readout noise. To enlarge the field-of-view (FOV), each EMCCD sensor is coupled to an x-ray phosphor through a fiberoptic taper. Two EMCCD camera modules are used in our prototype to form a computer-controlled array; however, larger arrays are under development. The new GUI provides patient registration, EMCCD module control, image acquisition, and patient image review. Images from the array are stitched into a 2kx1k pixel image that can be acquired and saved at a rate of 17 Hz (faster with pixel binning). When reviewing the patient's data, the operator can select images from the patient's directory tree listed by the GUI and cycle through the images using a slider bar. Commonly used camera parameters including exposure time, trigger mode, and individual EMCCD gain can be easily adjusted using the GUI. The GUI is designed to accommodate expansion of the EMCCD array to even larger FOVs with more modules. The high-resolution, high-sensitivity EMCCD modular-array SSXII imager with the new user-friendly GUI should enable angiographers and interventionalists to visualize smaller vessels and endovascular devices, helping them to make more accurate diagnoses and to perform more precise image-guided interventions.
Azimifar, Farhad; Hassani, Kamran; Saveh, Amir Hossein; Ghomsheh, Farhad Tabatabai
2017-11-14
Several methods including free-hand technique, fluoroscopic guidance, image-guided navigation, computer-assisted surgery system, robotic platform and patient's specific templates are being used for pedicle screw placement. These methods have screw misplacements and are not always easy to be applied. Furthermore, it is necessary to expose completely a large portions of the spine in order to access fit entirely around the vertebrae. In this study, a multi-level patient's specific template with medium invasiveness was proposed for pedicle screw placement in the scoliosis surgery. It helps to solve the problems related to the soft tissues removal. After a computer tomography (CT) scan of the spine, the templates were designed based on surgical considerations. Each template was manufactured using three-dimensional printing technology under a semi-flexible post processing. The templates were placed on vertebras at four points-at the base of the superior-inferior articular processes on both left-right sides. This helps to obtain less invasive and more accurate procedure as well as true-stable and easy placement in a unique position. The accuracy of screw positions was confirmed by CT scan after screw placement. The result showed the correct alignment in pedicle screw placement. In addition, the template has been initially tested on a metal wire series Moulage (height 70 cm and material is PVC). The results demonstrated that it could be possible to implement it on a real patient. The proposed template significantly reduced screw misplacements, increased stability, and decreased the sliding & the intervention invasiveness.
Guided Interventions for Prostate Cancer Using 3D-Transurethral Ultrasound and MRI Fusion
2015-10-01
AWARD NUMBER: W81XWH-14-1-0461 TITLE: Guided Interventions for Prostate Cancer Using 3D-Transurethral Ultrasound and MRI Fusion PRINCIPAL...Sep 2014 - 28 Sep 2015 4. TITLE AND SUBTITLE 5a. CONTRACT NUMBER Guided Interventions for Prostate Cancer Using 3D- Transurethral Ultrasound and...Magnetic Resonance- Ultrasound (MR-US) fusion allows for specific targeting of the tumors in real-time during clinical interventions, outside of an MR
Kim, Min-Su; Kim, Go-Woon; Rho, Young-Soo; Kwon, Kee-Hwan; Chung, Eun-Jae
2017-05-01
This retrospective study was carried out to investigate the effectiveness and safety of office-based electromyography-guided injection of botulinum toxin in the cricopharyngeus muscle of patients who did not show upper esophageal sphincter passage in a swallowing study in spite of maximal swallowing rehabilitation. Thirty-six patients who showed no or limited ability to oral feed after maximum swallowing rehabilitation were enrolled. Video fluoroscopic swallowing study, flexible endoscopic evaluation of swallowing, disability rating scale, penetration aspiration score, and National Institutes of Health swallowing safety scale were used in the evaluation of dysphagia. Success was defined as nondependence on gastrostomy for patients who previously were dependent on gastrostomy and improvement in disability rating scale score after botulinum toxin injections. The total success rate was 63.9%. The complication rate was very low, with only 1 patient showing temporary unilateral vocal fold paralysis. Botulinum toxin injection was more effective in patients with cranial nerve IX or X palsy than in those without it ( P = .006). This procedure can be a simple, safe, and effective tool in patients with cricopharyngeal dysfunction after swallowing rehabilitation, especially for cranial nerve IX or X palsy.
Percutaneous Image-Guided Aspiration and Sclerosis of Adventitial Cystic Disease of the Femoral Vein
DOE Office of Scientific and Technical Information (OSTI.GOV)
Johnson, Jason M.; Kiankhooy, Armin; Bertges, Daniel J.
2009-07-15
Adventitial cystic disease (ACD), also known as cystic mucoid or myxomatous degeneration, is a rare vascular disease mainly seen in arteries. Seventeen cases have been reported in the world literature. We report the first known case of ACD successfully treated with percutaneous image-guided ethanol sclerosis. Computed tomography showed a cystic mass adherent to the wall of the common femoral vein. An ultrasound examination revealed a deep venous thrombosis of the leg, secondary to extrinsic compression of the common femoral vein. Three years prior to our procedure, the cyst was aspirated, which partially relieved the patient's symptoms. Over the following 3more » years the patient's symptoms worsened and a 10-cm discrepancy in thigh size developed, in addition to the deep venous thrombosis associated with lower-extremity edema. Using ultrasound guidance and fluoroscopic control, the cyst was drained and then sclerosed with absolute ethanol. The patient's symptoms and leg swelling resolved completely within several weeks. Follow-up physical examination and duplex ultrasound 6 months following sclerosis demonstrated resolution of the symptoms and elimination of the extrinsic compression effect of the ACD on the common femoral vein.« less
Multiple template-based fluoroscopic tracking of lung tumor mass without implanted fiducial markers
NASA Astrophysics Data System (ADS)
Cui, Ying; Dy, Jennifer G.; Sharp, Gregory C.; Alexander, Brian; Jiang, Steve B.
2007-10-01
Precise lung tumor localization in real time is particularly important for some motion management techniques, such as respiratory gating or beam tracking with a dynamic multi-leaf collimator, due to the reduced clinical tumor volume (CTV) to planning target volume (PTV) margin and/or the escalated dose. There might be large uncertainties in deriving tumor position from external respiratory surrogates. While tracking implanted fiducial markers has sufficient accuracy, this procedure may not be widely accepted due to the risk of pneumothorax. Previously, we have developed a technique to generate gating signals from fluoroscopic images without implanted fiducial markers using a template matching method (Berbeco et al 2005 Phys. Med. Biol. 50 4481-90, Cui et al 2007 Phys. Med. Biol. 52 741-55). In this paper, we present an extension of this method to multiple-template matching for directly tracking the lung tumor mass in fluoroscopy video. The basic idea is as follows: (i) during the patient setup session, a pair of orthogonal fluoroscopic image sequences are taken and processed off-line to generate a set of reference templates that correspond to different breathing phases and tumor positions; (ii) during treatment delivery, fluoroscopic images are continuously acquired and processed; (iii) the similarity between each reference template and the processed incoming image is calculated; (iv) the tumor position in the incoming image is then estimated by combining the tumor centroid coordinates in reference templates with proper weights based on the measured similarities. With different handling of image processing and similarity calculation, two such multiple-template tracking techniques have been developed: one based on motion-enhanced templates and Pearson's correlation score while the other based on eigen templates and mean-squared error. The developed techniques have been tested on six sequences of fluoroscopic images from six lung cancer patients against the reference tumor positions manually determined by a radiation oncologist. The tumor centroid coordinates automatically detected using both methods agree well with the manually marked reference locations. The eigenspace tracking method performs slightly better than the motion-enhanced method, with average localization errors less than 2 pixels (1 mm) and the error at a 95% confidence level of about 2-4 pixels (1-2 mm). This work demonstrates the feasibility of direct tracking of a lung tumor mass in fluoroscopic images without implanted fiducial markers using multiple reference templates.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dhou, S; Cai, W; Hurwitz, M
2015-06-15
Purpose: Respiratory-correlated cone-beam CT (4DCBCT) images acquired immediately prior to treatment have the potential to represent patient motion patterns and anatomy during treatment, including both intra- and inter-fractional changes. We develop a method to generate patient-specific motion models based on 4DCBCT images acquired with existing clinical equipment and used to generate time varying volumetric images (3D fluoroscopic images) representing motion during treatment delivery. Methods: Motion models are derived by deformably registering each 4DCBCT phase to a reference phase, and performing principal component analysis (PCA) on the resulting displacement vector fields. 3D fluoroscopic images are estimated by optimizing the resulting PCAmore » coefficients iteratively through comparison of the cone-beam projections simulating kV treatment imaging and digitally reconstructed radiographs generated from the motion model. Patient and physical phantom datasets are used to evaluate the method in terms of tumor localization error compared to manually defined ground truth positions. Results: 4DCBCT-based motion models were derived and used to generate 3D fluoroscopic images at treatment time. For the patient datasets, the average tumor localization error and the 95th percentile were 1.57 and 3.13 respectively in subsets of four patient datasets. For the physical phantom datasets, the average tumor localization error and the 95th percentile were 1.14 and 2.78 respectively in two datasets. 4DCBCT motion models are shown to perform well in the context of generating 3D fluoroscopic images due to their ability to reproduce anatomical changes at treatment time. Conclusion: This study showed the feasibility of deriving 4DCBCT-based motion models and using them to generate 3D fluoroscopic images at treatment time in real clinical settings. 4DCBCT-based motion models were found to account for the 3D non-rigid motion of the patient anatomy during treatment and have the potential to localize tumor and other patient anatomical structures at treatment time even when inter-fractional changes occur. This project was supported, in part, through a Master Research Agreement with Varian Medical Systems, Inc., Palo Alto, CA. The project was also supported, in part, by Award Number R21CA156068 from the National Cancer Institute.« less
Public Attitudes Toward Guided Internet-Based Therapies: Web-Based Survey Study.
Apolinário-Hagen, Jennifer; Harrer, Mathias; Kählke, Fanny; Fritsche, Lara; Salewski, Christel; Ebert, David Daniel
2018-05-15
Internet interventions have been proposed to improve the accessibility and use of evidence-based psychological treatments. However, little is known about attitudes toward such treatments, which can be an important barrier to their use. This study aimed to (1) determine attitudes toward guided internet interventions, (2) assess its acceptability compared with other internet-based formats, and (3) explore predictors of acceptance. A convenience-sample Web-based survey (N=646) assessed attitudes toward guided internet therapies (ie, perceived usefulness and helpfulness, and advantage relative to face-to-face therapy), preferences for delivery modes (ie, e-preference: guided internet interventions, unguided internet interventions, or videoconferencing psychotherapy), and potential predictors of attitudes and preferences: sociodemographics, help-seeking-related variables, attachment style, and perceived stress. Although most participants perceived internet interventions as useful or helpful (426/646, 65.9%), a few indicated their advantage relative to face-to-face therapy (56/646, 8.7%). Most participants preferred guided internet interventions (252/646, 39.0%) over videoconferencing psychotherapy (147/646, 22.8%), unguided internet interventions (124/646, 19.2%), and not using internet interventions (121/646, 18.8%; missing data: 1/646, 0.2%). Attachment avoidance and stress were related to e-preference (all P<.05). Moreover, preference for therapist-guided internet interventions was higher for individuals who were aware of internet-based treatment (χ 2 6 =12.8; P=.046). Participants assessed therapist-guided internet interventions as helpful, but not equivalent to face-to-face therapies. The vast majority (523/646, 81.0%) of the participants were potentially willing to use internet-based approaches. In lieu of providing patients with only one specific low-intensity treatment, implementation concepts should offer several options, including guided internet interventions, but not limited to them. Conversely, our results also indicate that efforts should focus on increasing public knowledge about internet interventions, including information about their effectiveness, to promote acceptance and uptake. ©Jennifer Apolinário-Hagen, Mathias Harrer, Fanny Kählke, Lara Fritsche, Christel Salewski, David Daniel Ebert. Originally published in JMIR Mental Health (http://mental.jmir.org), 15.05.2018.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wybranski, Christian, E-mail: Christian.Wybranski@uk-koeln.de; Pech, Maciej; Lux, Anke
ObjectiveTo assess the feasibility of a hybrid approach employing MRI-guided bile duct (BD) puncture for subsequent fluoroscopy-guided biliary interventions in patients with non-dilated (≤3 mm) or dilated BD (≥3 mm) but unfavorable conditions for ultrasonography (US)-guided BD puncture.MethodsA total of 23 hybrid interventions were performed in 21 patients. Visualization of BD and puncture needles (PN) in the interventional MR images was rated on a 5-point Likert scale by two radiologists. Technical success, planning time, BD puncture time and positioning adjustments of the PN as well as technical success of the biliary intervention and complication rate were recorded.ResultsVisualization even of third-order non-dilated BDmore » and PN was rated excellent by both radiologists with good to excellent interrater agreement. MRI-guided BD puncture was successful in all cases. Planning and BD puncture times were 1:36 ± 2.13 (0:16–11:07) min. and 3:58 ± 2:35 (1:11–9:32) min. Positioning adjustments of the PN was necessary in two patients. Repeated capsular puncture was not necessary in any case. All biliary interventions were completed successfully without major complications.ConclusionA hybrid approach which employs MRI-guided BD puncture for subsequent fluoroscopy-guided biliary intervention is feasible in clinical routine and yields high technical success in patients with non-dilated BD and/or unfavorable conditions for US-guided puncture. Excellent visualization of BD and PN in near-real-time interventional MRI allows successful cannulation of the BD.« less
Intraoperative panoramic image using alignment grid, is it accurate?
Apivatthakakul, T; Duanghakrung, M; Luevitoonvechkit, S; Patumasutra, S
2013-07-01
Minimally invasive orthopedic trauma surgery relies heavily on intraoperative fluoroscopic images to evaluate the quality of fracture reduction and fixation. However, fluoroscopic images have a narrow field of view and often cannot visualize the entire long bone axis. To compare the coronal femoral alignment between conventional X-rays to that achieved with a new method of acquiring a panoramic intraoperative image. Twenty-four cadaveric femurs with simple diaphyseal fractures were fixed with an angulated broad DCP to create coronal plane malalignment. An intraoperative alignment grid was used to help stitch different fluoroscopic images together to produce a panoramic image. A conventional X-ray of the entire femur was then performed. The coronal plane angulation in the panoramic images was then compared to the conventional X-rays using a Wilcoxon signed rank test. The mean angle measured from the panoramic view was 173.9° (range 169.3°-178.0°) with median of 173.2°. The mean angle measured from the conventional X-ray was 173.4° (range 167.7°-178.7°) with a median angle of 173.5°. There was no significant difference between both methods of measurement (P = 0.48). Panoramic images produced by stitching fluoroscopic images together with help of an alignment grid demonstrated the same accuracy at evaluating the coronal plane alignment of femur fractures as conventional X-rays.
Fluoroscopic and radiographic evaluation of tracheal collapse in dogs: 62 cases (2001-2006).
Macready, Dawn M; Johnson, Lynelle R; Pollard, Rachel E
2007-06-15
To compare the use of radiography and fluoroscopy for detection and grading of tracheal collapse in dogs. Retrospective case series. Animals-62 dogs with tracheal collapse. For each dog, tracheal collapse was confirmed fluoroscopically and lateral cervical and thoracic radiographic views were reviewed. A board-certified radiologist (who was unaware of the dogs' clinical history) evaluated the cervical, thoracic inlet, thoracic, carinal, and main stem bronchial regions in all fluoroscopic videos and radiographic images for evidence of collapse. Cervical, thoracic inlet, thoracic, and carinal regions in both radio-graphic and fluoroscopic studies were graded for collapse (0%, 25%, 50%, 75%, or 100% decrease in diameter). Lateral cervical and thoracic radiographic images were available for 54 dogs, and inspiratory and expiratory lateral cervical and thoracic radiographic images were available for 8 dogs. For detection of tracheal collapse, assessment of radiographic views was sensitive and had the best negative predictive value in the cervical and thoracic inlet regions. Assessment of radiographic views was most specific and had the best positive predictive value in the thoracic inlet, thoracic, carina, and main stem bronchial regions. Radiography underestimated the degree of collapse in all areas. Review of inspiratory and expiratory views improved the accuracy of radiography for tracheal collapse diagnosis only slightly. Compared with fluoroscopy, radiography underestimated the frequency and degree of tracheal collapse. However, radiography appears to be useful for screening dogs with potential tracheal collapse.
Gibby, Jacob T; Swenson, Samuel A; Cvetko, Steve; Rao, Raj; Javan, Ramin
2018-06-22
Augmented reality has potential to enhance surgical navigation and visualization. We determined whether head-mounted display augmented reality (HMD-AR) with superimposed computed tomography (CT) data could allow the wearer to percutaneously guide pedicle screw placement in an opaque lumbar model with no real-time fluoroscopic guidance. CT imaging was obtained of a phantom composed of L1-L3 Sawbones vertebrae in opaque silicone. Preprocedural planning was performed by creating virtual trajectories of appropriate angle and depth for ideal approach into the pedicle, and these data were integrated into the Microsoft HoloLens using the Novarad OpenSight application allowing the user to view the virtual trajectory guides and CT images superimposed on the phantom in two and three dimensions. Spinal needles were inserted following the virtual trajectories to the point of contact with bone. Repeat CT revealed actual needle trajectory, allowing comparison with the ideal preprocedural paths. Registration of AR to phantom showed a roughly circular deviation with maximum average radius of 2.5 mm. Users took an average of 200 s to place a needle. Extrapolation of needle trajectory into the pedicle showed that of 36 needles placed, 35 (97%) would have remained within the pedicles. Needles placed approximated a mean distance of 4.69 mm in the mediolateral direction and 4.48 mm in the craniocaudal direction from pedicle bone edge. To our knowledge, this is the first peer-reviewed report and evaluation of HMD-AR with superimposed 3D guidance utilizing CT for spinal pedicle guide placement for the purpose of cannulation without the use of fluoroscopy.
VCSim3: a VR simulator for cardiovascular interventions.
Korzeniowski, Przemyslaw; White, Ruth J; Bello, Fernando
2018-01-01
Effective and safe performance of cardiovascular interventions requires excellent catheter/guidewire manipulation skills. These skills are currently mainly gained through an apprenticeship on real patients, which may not be safe or cost-effective. Computer simulation offers an alternative for core skills training. However, replicating the physical behaviour of real instruments navigated through blood vessels is a challenging task. We have developed VCSim3-a virtual reality simulator for cardiovascular interventions. The simulator leverages an inextensible Cosserat rod to model virtual catheters and guidewires. Their mechanical properties were optimized with respect to their real counterparts scanned in a silicone phantom using X-ray CT imaging. The instruments are manipulated via a VSP haptic device. Supporting solutions such as fluoroscopic visualization, contrast flow propagation, cardiac motion, balloon inflation, and stent deployment, enable performing a complete angioplasty procedure. We present detailed results of simulation accuracy of the virtual instruments, along with their computational performance. In addition, the results of a preliminary face and content validation study conveyed on a group of 17 interventional radiologists are given. VR simulation of cardiovascular procedure can contribute to surgical training and improve the educational experience without putting patients at risk, raising ethical issues or requiring expensive animal or cadaver facilities. VCSim3 is still a prototype, yet the initial results indicate that it provides promising foundations for further development.
Adherence predictors in an Internet-based Intervention program for depression.
Castro, Adoración; López-Del-Hoyo, Yolanda; Peake, Christian; Mayoral, Fermín; Botella, Cristina; García-Campayo, Javier; Baños, Rosa María; Nogueira-Arjona, Raquel; Roca, Miquel; Gili, Margalida
2018-05-01
Internet-delivered psychotherapy has been demonstrated to be effective in the treatment of depression. Nevertheless, the study of the adherence in this type of the treatment reported divergent results. The main objective of this study is to analyze predictors of adherence in a primary care Internet-based intervention for depression in Spain. A multi-center, three arm, parallel, randomized controlled trial was conducted with 194 depressive patients, who were allocated in self-guided or supported-guided intervention. Sociodemographic and clinical characteristics were gathered using a case report form. The Mini international neuropsychiatric interview diagnoses major depression. Beck Depression Inventory was used to assess depression severity. The visual analogic scale assesses the respondent's self-rated health and Short Form Health Survey was used to measure the health-related quality of life. Age results a predictor variable for both intervention groups (with and without therapist support). Perceived health is a negative predictor of adherence for the self-guided intervention when change in depression severity was included in the model. Change in depression severity results a predictor of adherence in the support-guided intervention. Our findings demonstrate that in our sample, there are differences in sociodemographic and clinical variables between active and dropout participants and we provide adherence predictors in each intervention condition of this Internet-based program for depression (self-guided and support-guided). It is important to point that further research in this area is essential to improve tailored interventions and to know specific patients groups can benefit from these interventions.
ERIC Educational Resources Information Center
Carlon, Sarah; Carter, Mark; Stephenson, Jennifer
2017-01-01
A pilot study of the effectiveness of guided access to websites that provide information on intervention options for children with autism spectrum disorder (ASD) was conducted with 12 parents of preschool aged children with ASD. Guided access to reliable websites that included information about the effcacy of interventions for ASD (Raising…
Dagnino, Giulio; Georgilas, Ioannis; Morad, Samir; Gibbons, Peter; Tarassoli, Payam; Atkins, Roger; Dogramadzi, Sanja
2017-08-01
Joint fractures must be accurately reduced minimising soft tissue damages to avoid negative surgical outcomes. To this regard, we have developed the RAFS surgical system, which allows the percutaneous reduction of intra-articular fractures and provides intra-operative real-time 3D image guidance to the surgeon. Earlier experiments showed the effectiveness of the RAFS system on phantoms, but also key issues which precluded its use in a clinical application. This work proposes a redesign of the RAFS's navigation system overcoming the earlier version's issues, aiming to move the RAFS system into a surgical environment. The navigation system is improved through an image registration framework allowing the intra-operative registration between pre-operative CT images and intra-operative fluoroscopic images of a fractured bone using a custom-made fiducial marker. The objective of the registration is to estimate the relative pose between a bone fragment and an orthopaedic manipulation pin inserted into it intra-operatively. The actual pose of the bone fragment can be updated in real time using an optical tracker, enabling the image guidance. Experiments on phantom and cadavers demonstrated the accuracy and reliability of the registration framework, showing a reduction accuracy (sTRE) of about [Formula: see text] (phantom) and [Formula: see text] (cadavers). Four distal femur fractures were successfully reduced in cadaveric specimens using the improved navigation system and the RAFS system following the new clinical workflow (reduction error [Formula: see text], [Formula: see text]. Experiments showed the feasibility of the image registration framework. It was successfully integrated into the navigation system, allowing the use of the RAFS system in a realistic surgical application.
[Navigated drilling for femoral head necrosis. Experimental and clinical results].
Beckmann, J; Tingart, M; Perlick, L; Lüring, C; Grifka, J; Anders, S
2007-05-01
In the early stages of osteonecrosis of the femoral head, core decompression by exact drilling into the ischemic areas can reduce pain and achieve reperfusion. Using computer aided surgery, the precision of the drilling can be improved while simultaneously lowering radiation exposure time for both staff and patients. We describe the experimental and clinical results of drilling under the guidance of the fluoroscopically-based VectorVision navigation system (BrainLAB, Munich, Germany). A total of 70 sawbones were prepared mimicking an osteonecrosis of the femoral head. In two experimental models, bone only and obesity, as well as in a clinical setting involving ten patients with osteonecrosis of the femoral head, the precision and the duration of radiation exposure were compared between the VectorVision system and conventional drilling. No target was missed. For both models, there was a statistically significant difference in terms of the precision, the number of drilling corrections as well as the radiation exposure time. The average distance to the desired midpoint of the lesion of both models was 0.48 mm for navigated drilling and 1.06 mm for conventional drilling, the average drilling corrections were 0.175 and 2.1, and the radiation exposure time less than 1 s and 3.6 s, respectively. In the clinical setting, the reduction of radiation exposure (below 1 s for navigation compared to 56 s for the conventional technique) as well as of drilling corrections (0.2 compared to 3.4) was also significant. Computer guided drilling using the fluoroscopically based VectorVision navigation system shows a clearly improved precision with a enormous simultaneous reduction in radiation exposure. It is therefore recommended for clinical routine.
Precision of computer-assisted core decompression drilling of the femoral head.
Beckmann, J; Goetz, J; Baethis, H; Kalteis, T; Grifka, J; Perlick, L
2006-08-01
Osteonecrosis of the femoral head is a local destructive disease with progression into devastating stages. Left untreated it mostly leads to severe secondary osteoarthrosis and early endoprosthetic joint replacement. Core decompression by exact drilling into the ischemic areas can be performed in early stages according to Ficat or ARCO. Computer-aided surgery might enhance the precision of the drilling and lower the radiation exposure time of both staff and patients. The aim of this study was to evaluate the precision of the fluoroscopically based VectorVision navigation system in an in vitro model. Thirty sawbones were prepared with a defect filled up with a radiopaque gypsum sphere mimicking the osteonecrosis. Twenty sawbones were drilled by guidance of an intraoperative navigation system VectorVision (BrainLAB, Munich, Germany) and 10 sawbones by fluoroscopic control only. No gypsum sphere was missed. There was a statistically significant difference regarding the three-dimensional deviation (Euclidian norm) as well as maximum deviation in x-, y- or z-direction (maximum norm) to the desired mid-point of the lesion, with a mean of 0.51 and 0.4 mm in the navigated group and 1.1 and 0.88 mm in the control group, respectively. Furthermore, significant difference was found in the number of drilling corrections as well as the radiation time needed: no second drilling or correction of drilling direction was necessary in the navigated group compared to 1.4 in the control group. The radiation time needed was less than 1 s compared to 3.1 s, respectively. The fluoroscopy-based VectorVision navigation system shows a high feasibility of computer-guided drilling with a clear reduction of radiation exposure time and can therefore be integrated into clinical routine. The additional time needed is acceptable regarding the simultaneous reduction of radiation time.
Wu, Y; Li, K-L; Zheng, J; Zhang, C-Y; Liu, X-Y; Cui, Z-M; Yu, Z-M; Wang, R-X; Wang, W
2015-09-01
The purpose of this study was to prospectively evaluate the efficacy and safety of remote magnetic navigation (RMN) in comparison with manual catheter navigation (MCN) in performing ventricular tachycardia ablation. An electronic search was performed using PubMed (1948-2013) and EMBASE (1974-2013) studies comparing RMN with MCN which were published prior to 31 December 2013. Outcomes of interest were as follows: acute success, recurrence rate, complications, total procedure and fluoroscopic times. Standard mean difference (SMD) and its 95 % confidence interval (CI) were used for continuous outcomes; odds ratios (OR) were reported for dichotomous variables. Four non-randomised studies, including a total of 328 patients, were identified. RMN was deployed in 191 patients. Acute success and long-term freedom from arrhythmias were not significantly different between the RMN and control groups (OR 1.845, 95 % CI 0.731-4.659, p = 0.195 and OR 0.676, 95 % CI 0.383-1.194, p = 0.177, respectively). RMN was associated with less peri-procedural complications (OR 0.279, 95 % CI 0.092-0.843, p = 0.024). Shorter procedural and fluoroscopy times were achieved (95 % CI -0.487 to -0.035, p = 0.024 and 95 % CI -1.467 to -0.984, p<0.001, respectively). The acute and long-term success rates for VT ablation are equal between RMN and MCN, whereas the RMN-guided procedure can be performed with a lower complication rate and less procedural and fluoroscopic times. More prospective randomised trials will be needed to better evaluate the superior role of RMN for catheter ablation of ventricular tachycardia.
NASA Astrophysics Data System (ADS)
Hoopes, P. J.; Eskey, Cliff J.; Attawia, Mohammed; Patel, Samit J.; Ryan, T. P.; Pellegrino, Richard; Bergeron, Jeffrey A.
2005-04-01
Pathological involvement of the basivertebral nerve (BVN), an intraosseous vertebral nerve, may play a significant role in some forms of back pain. This study was designed to assess the feasibility and effects of thermal ablation of the lumbar basivertebral nerve in mature sheep. Sixteen adult female sheep weighing 65-80 kg were anesthetized and positioned for ventral recumbent surgery. Under fluoroscopic guidance, two bilarterally oposed 5mm active length rediofrequency (RF) electrodes (1.65mm diameter were perfutaneously placed in select lumbar vertebrae at a relative angle of 70 degrees with a 5 mm tip separation. The elctrodes were advanced to the region of the vertebral bodies which contained the BVN. A thermal dose of 95° C/720 seconds was administered. Animals were survived for 2, 14, 90, or 180 days post-treatment. Clinical, radiologic and pathologic investigations were performed to determine the effect of the heat on the BVN and associated tissues. Thermal damage to the basivertebral neurovascular bundle was characterized by early hemorrhage and necrosis, followed by inflammation and fibrosis. Although there wasa significant revascularization of the treated bone marow regions, there was no evidence of basivertebral nerve survival or regeneration regeneration. In addition to ablation of teh basivertebral nerovascular bundle, the areas receiving the greatest treatment demonstrated initial mild local osteolysis and demineralization of the vertebral body bone and regional depopulation of the vertebral bone marrow cellular elements. Significant bone remodeling in the affected areas had begun by 14 days post-treatment. Bone remodeling was characterized by conventional osteoblast proliferation, osteoid deposition, and mineralization. This study demonstrated the ability to accurately, reproducibly, and safely ablate the basivertebral nerve and neurovascular bundle in mature sheep using a fluoroscopically guided percutaneously delivered radiofrequency technique.
Maduri, Rodolfo; Bobinski, Lukas; Duff, John Michael
2017-02-01
Standard translaminar approaches for intradural extramedullary (IDEM) tumors require extensive soft tissue dissection and partial facet removal. Ventral lesions may necessitate wider bone resection with subsequent possible spinal instability. Any manipulation of an already compromised spinal cord may lead to neurological injury. We describe an image-guided minimal access technique for IDEM tumor resection. Retrospective chart review of 13 consecutive patients after institutional ethics committee approval. We superimpose preoperative magnetic resonance imaging data with intraoperative 3-dimensional fluoroscopic images, allowing to simultaneously visualize osseous anatomy and the soft tissue lesion using appropriate windowing. We then plan optimal angle of trajectory to the tumor, which defines the skin incision and the transmuscular trajectory. A tubular retractor is placed to span the tumor. Microsurgical tumor resection is then carried out using this angle of approach. Thirteen patients (mean age. 57 years; male-to-female ratio, 10:3) were operated on during 28 months. Gross total resection was achieved in all patients. Neurological improvement occurred in 12 of the 13 patients. There was no neurological deficit outside of the expected sensory loss due to intentional nerve root sacrifice. No mechanical pain nor tumor recurrence were noted during the follow-up (mean, 16 months; range, 2-30 months). Image merge tailored access resection appears to be at least equivalent in terms of tumor resection, blood loss, and complications to other tubular techniques. It may reduce risks of neurological deficit and spine instability. Image merge tailored access resection is a novel application of merging intraoperative fluoroscopic images with preoperative magnetic resonance images for tailored IDEM resection. Copyright © 2016 Elsevier Inc. All rights reserved.
The Uses of Force on Spaceship Earth: Revolution and Intervention in the '70's. A Study Guide.
ERIC Educational Resources Information Center
Rivera, Charles R.; And Others
The relationship between internal revolution and subsequent intervention by a foreign power is examined in this guide book for senior high students. Why nations pursue a policy of military intervention and what other alternatives are available are two major questions investigated. Intervention and non-intervention are both determined policies that…
NASA Technical Reports Server (NTRS)
Newell, J. D.; Keller, R. A.; Baily, N. A.
1974-01-01
A simple method for outlining or contouring any area defined by a change in film density or fluoroscopic screen intensity is described. The entire process, except for the positioning of an electronic window, is accomplished using a small computer having appropriate softwave. The electronic window is operator positioned over the area to be processed. The only requirement is that the window be large enough to encompass the total area to be considered.
Maximizing Lumen Gain With Directional Atherectomy.
Stanley, Gregory A; Winscott, John G
2016-08-01
To describe the use of a low-pressure balloon inflation (LPBI) technique to delineate intraluminal plaque and guide directional atherectomy in order to maximize lumen gain and achieve procedure success. The technique is illustrated in a 77-year-old man with claudication who underwent superficial femoral artery revascularization using a HawkOne directional atherectomy catheter. A standard angioplasty balloon was inflated to 1 to 2 atm during live fluoroscopy to create a 3-dimensional "lumenogram" of the target lesion. Directional atherectomy was performed only where plaque impinged on the balloon at a specific fluoroscopic orientation. The results of the LPBI technique were corroborated with multimodality diagnostic imaging, including digital subtraction angiography, intravascular ultrasound, and intra-arterial pressure measurements. With the LPBI technique, directional atherectomy can routinely achieve <10% residual stenosis, as illustrated in this case, thereby broadly supporting a no-stent approach to lower extremity endovascular revascularization. © The Author(s) 2016.
Multifocal Aspergillus terreus discospondylitis in two German shepherd dogs.
Berry, W L; Leisewitz, A L
1996-12-01
Multifocal fungal (Aspergillus terreus) discospondylitis was diagnosed in 2 German shepherd dogs. In one dog, the aetiology was established by means of fluoroscopic-guided disc aspiration, cytology and culture of disc material and urine. Disseminated aspergillosis was confirmed at necropsy and A. terreus cultured from numerous organs in this dog. The aetiology in the other dog was not established until therapeutic failure forced surgical curettage of disc material from which the fungus was cultured. Ketoconazole therapy failed to effect an improvement, and at necropsy, disease was localised to the spinal column, with A. terreus cultured from the affected discs and associated vertebrae. Immunodeficiency was suspected in both cases. In the case of disseminated disease a reduced lymphocyte blastogenic response was demonstrated. Reduced IgA was shown in both cases. The German shepherd breed seems to be predisposed to Aspergillus infections and IgA deficiency.
Kang, Keum Nae; Kim, Tae Woong; Koh, Jin Woo; Oh, Han Byeol; Mun, Jong-Uk; Seo, Mi Sook; Kim, Young Uk
2017-06-01
Transforaminal epidural glucocorticoids administration is widely performed for the management of lumbosacral radiculopathy. However, it may worsen the condition of patients with type 2 diabetes mellitus (DM). Polydeoxyribonucleotide (PDRN) was recently noted as a substitute for glucocorticoids. A 44-year-old male patient was admitted to our pain clinic with symptoms of low back pain with severe pain and tingling sensation of left posterolateral leg. He had type 2 DM medicated with Glimepiride and Metformin. Blood glucose level was 367 mg/dL. He declined to use glucocorticoid. He was diagnosed as left foraminal disc protrusion at L4-5, left subarticular disc protrusion at L5-S1. Fluoroscopically guided transforaminal epidural PDRN injections were carried out. The patient was followed up for more than 6 months and demonstrated good improvement in lumbosacral radiculopathy without any complications. This is the first successful report on epidural injection of PDRN.
Treatment of lymphangiomas in children: an update of Picibanil (OK-432) sclerotherapy.
Greinwald, J H; Burke, D K; Sato, Y; Poust, R I; Kimura, K; Bauman, N M; Smith, R J
1999-10-01
Picibanil (OK-432) is a sclerosing agent derived from a low-virulence strain of Streptococcus pyogenes that induces regression of macrocystic lymphangiomas. This report describes a prospective, nonrandomized trial to evaluate the efficacy of Picibanil in the treatment of 13 affected children ranging in age from 1 to 94 months. On average, 4.1 fluoroscopically guided intracystic injections were performed per child, with an average total dose of 0.56 mg of Picibanil. As judged by physical examination and radiographic studies, 5 children (42%) showed a complete or substantial response, and 2 children (16%) showed an intermediate response. No response was seen in 5 children (42%), 2 of whom had massive craniofacial lymphangioma. Factors that contribute to failure with Picibanil sclerotherapy are the presence of a significant microcystic component to the lesion, massive craniofacial involvement, and previous surgical resection. Macrocystic lymphangiomas of the infratemporal fossa or cervical area have the best response to therapy.
[The history and development of computer assisted orthopaedic surgery].
Jenny, J-Y
2006-10-01
Computer assisted orthopaedic surgery (CAOS) was developed to improve the accuracy of surgical procedures. It has improved dramatically over the last years, being transformed from an experimental, laboratory procedure into a routine procedure theoretically available to every orthopaedic surgeon. The first field of application of computer assistance was neurosurgery. After the application of computer guided spinal surgery, the navigation of total hip and knee joints became available. Currently, several applications for computer assisted surgery are available. At the beginning of navigation, a preoperative CT-scan or several fluoroscopic images were necessary. The imageless systems allow the surgeon to digitize patient anatomy at the beginning of surgery without any preoperative imaging. The future of CAOS remains unknown, but there is no doubt that its importance will grow in the next 10 years, and that this technology will probably modify the conventional practice of orthopaedic surgery.
PLUS: open-source toolkit for ultrasound-guided intervention systems.
Lasso, Andras; Heffter, Tamas; Rankin, Adam; Pinter, Csaba; Ungi, Tamas; Fichtinger, Gabor
2014-10-01
A variety of advanced image analysis methods have been under the development for ultrasound-guided interventions. Unfortunately, the transition from an image analysis algorithm to clinical feasibility trials as part of an intervention system requires integration of many components, such as imaging and tracking devices, data processing algorithms, and visualization software. The objective of our paper is to provide a freely available open-source software platform-PLUS: Public software Library for Ultrasound-to facilitate rapid prototyping of ultrasound-guided intervention systems for translational clinical research. PLUS provides a variety of methods for interventional tool pose and ultrasound image acquisition from a wide range of tracking and imaging devices, spatial and temporal calibration, volume reconstruction, simulated image generation, and recording and live streaming of the acquired data. This paper introduces PLUS, explains its functionality and architecture, and presents typical uses and performance in ultrasound-guided intervention systems. PLUS fulfills the essential requirements for the development of ultrasound-guided intervention systems and it aspires to become a widely used translational research prototyping platform. PLUS is freely available as open source software under BSD license and can be downloaded from http://www.plustoolkit.org.
West, Joseph F
2014-02-01
Diabetes remains a growing epidemic with widening health inequity gaps in disease management, self-management knowledge, access to care and outcomes. Yet there is a paucity of evaluation tools for community engaged interventions aimed at closing the gaps and improving health. The Guide to Community Preventive Services (the Community Guide) developed by the Task Force on Community Preventive Services (the Task Force) at the Centers for Disease Control and Prevention (CDC) recommends two healthcare system level interventions, case management interventions and disease management programs, to improve glycemic control. However, as a public health resource guide for diabetes interventions a model for community engagement is a glaringly absent component of the Community Guide recommendations. In large part there are few evidence-based interventions featuring community engagement as a practice and system-level focus of chronic disease and Type 2 diabetes management. The central argument presented in this paper is that the absence of these types of interventions is due to the lack of tools for modeling and evaluating such interventions, especially among disparate and poor populations. A conceptual model emphasizing action-oriented micro-level community engagement is needed to complement the Community Guide and serve as the basis for testing and evaluation of these kinds of interventions. A unique logic model advancing the Community Guide diabetes recommendations toward measureable and sustainable community engagement for improved Type 2 diabetes outcomes is presented. Copyright © 2013 Elsevier Ltd. All rights reserved.
Ultrasound-guided Interventions for Core and Hip Injuries in Athletes.
McCarthy, Eoghan; Hegazi, Tarek M; Zoga, Adam C; Morrison, William B; Meyers, William C; Poor, Alex E; Nevalainen, Mika T; Roedl, Johannes B
2016-09-01
Trauma and the mechanical strain of high-energy activity predispose athletes to pelvic injuries. Magnetic resonance imaging remains the primary modality for diagnosing these conditions, but ultrasonography-guided interventions are important in the management of core muscle, hip, and other pelvic conditions. This article reviews ultrasonography-guided interventions for injuries at the core, including the pelvis and hips. It reviews common injuries, procedure optimization, medication preparation, clinical evidence behind injections, tenotomy, and platelet-rich plasma. These interventions are especially important in athletes, because ultrasonography-guided procedures are often undertaken early in the treatment process, paralleling conservative rehabilitation to facilitate a faster return to play. Copyright © 2016 Elsevier Inc. All rights reserved.
Extended use of the GuideLiner in complex coronary interventions.
Chan, Pak Hei; Alegria-Barrero, Eduardo; Foin, Nicholas; Paulo, Manuel; Lindsay, Alistair C; Viceconte, Nicola; Di Mario, Carlo
2015-07-01
Challenging coronary anatomies including chronic total occlusions (CTO), extreme vessel tortuosity, diseased bypass grafts, and anomalous coronary arteries pose difficulties in coronary interventions. The GuideLiner is a monorail catheter originally developed to facilitate delivery of stents to target lesions in tortuous vessels. We conducted a study on the feasibility and safety of utilising this catheter in a wider array of complex coronary interventions. Consecutive patients undergoing coronary or peripheral interventions where a GuideLiner was used were recruited into this study. Patient demographics, lesion and vessel characteristics, procedural details and outcomes were prospectively entered into our database and analysed. From September 2009 to October 2011, 54 consecutive patients underwent coronary intervention in our institution using a GuideLiner; 21 out of 54 coronary applications were motivated by the need to increase support to cross CTOs, predominantly of the RCA. Anomalous or angulated take-off of the treatment vessels (31%), previously deployed proximal stents (15%), heavy proximal calcification (9%) and tortuosity (7%) accounted for the remaining reasons. One patient had successful renal denervation with the aid of a GuideLiner catheter. Procedural success was 98% in our series with no device-related periprocedural complications such as ostial dissection or myocardial necrosis. The use of a GuideLiner facilitates the approach to complex coronary interventions including chronic total occlusion and saphenous vein graft intervention by providing greater back-up support and easier engagement of coronary ostia.
Interventional articular and para-articular knee procedures
Lalam, Radhesh K; Winn, Naomi
2016-01-01
The knee is a common area of the body to undergo interventional procedures. This article discusses image-guided interventional issues specific to the knee area. The soft tissues in and around the knee are frequently affected by sport-related injuries and often need image-guided intervention. This article details the specific technical issues related to intervention in these soft tissues, including the iliotibial tract, fat pads, patellar tendon and other tendons, bursae and the meniscus. Most often, simple procedures such as injection and aspiration are performed without image guidance. Rarely image-guided diagnostic arthrography and therapeutic joint injections are necessary. The technique, indications and diagnostic considerations for arthrography are discussed in this article. Primary bone and soft-tissue tumours may involve the knee and adjacent soft tissues. Image-guided biopsies are frequently necessary for these lesions; this article details the technical issues related to image-guided biopsy around the knee. A number of newer ablation treatments are now available, including cryoablation, high-frequency ultrasound and microwave ablation. Radiofrequency ablation, however, still remains the most commonly employed ablation technique. The indications, technical and therapeutic considerations related to the application of this technique around the knee are discussed here. Finally, we briefly discuss some newer, but as of yet, unproven image-guided interventions for osteochondral lesions and Brodie's abscess. PMID:26682669
Dosimetry during intramedullary nailing of the tibia.
Kirousis, George; Delis, Harry; Megas, Panagiotis; Lambiris, Elias; Panayiotakis, George
2009-10-01
Intramedullary nailing under fluoroscopic guidance is a common operation. We studied the intraoperative radiation dose received by both the patient and the personnel. 25 intramedullary nailing procedures of the tibia were studied. All patients suffered from tibial fractures and were treated using the Grosse-Kempf intramedullary nail, with free-hand technique for fixation of the distal screws, under fluoroscopic guidance. The exposure, at selected positions, was recorded using an ion chamber, while the dose area product (DAP) was measured with a DAP meter, attached to the tube head. Thermoluminescent dosimeters (TLDs) were used to derive the occupational dose to the personnel, and also to monitor the surface dose on the gonads of some of the patients. The mean operation time was 101 (48-240) min, with a mean fluoroscopic time of 72 seconds and a mean DAP value of 75 cGy x cm(2). The surface dose to the gonads of the patients was less than 8.8 mGy during any procedure, and thus cannot be considered to be a contraindication for the use of this technique. Occupational dose differed substantially between members of the operating personnel, the maximum dose recorded being to the operator of the fluoroscopic equipment (0.11 mSv). Our findings underscore the care required by the primary operator not to exceed the dose constraint of 10 mSv per year. The rest of the operating personnel, although they do not receive very high doses, should focus on the dose optimization of the technique.
NASA Astrophysics Data System (ADS)
Song, Sang-Eun; Tokuda, Junichi; Tuncali, Kemal; Tempany, Clare; Hata, Nobuhiko
2012-02-01
Image guided prostate interventions have been accelerated by Magnetic Resonance Imaging (MRI) and robotic technologies in the past few years. However, transrectal ultrasound (TRUS) guided procedure still remains as vast majority in clinical practice due to engineering and clinical complexity of the MRI-guided robotic interventions. Subsequently, great advantages and increasing availability of MRI have not been utilized at its maximum capacity in clinic. To benefit patients from the advantages of MRI, we developed an MRI-compatible motorized needle guide device "Smart Template" that resembles a conventional prostate template to perform MRI-guided prostate interventions with minimal changes in the clinical procedure. The requirements and specifications of the Smart Template were identified from our latest MRI-guided intervention system that has been clinically used in manual mode for prostate biopsy. Smart Template consists of vertical and horizontal crossbars that are driven by two ultrasonic motors via timing-belt and mitergear transmissions. Navigation software that controls the crossbar position to provide needle insertion positions was also developed. The software can be operated independently or interactively with an open-source navigation software, 3D Slicer, that has been developed for prostate intervention. As preliminary evaluation, MRI distortion and SNR test were conducted. Significant MRI distortion was found close to the threaded brass alloy components of the template. However, the affected volume was limited outside the clinical region of interest. SNR values over routine MRI scan sequences for prostate biopsy indicated insignificant image degradation during the presence of the robotic system and actuation of the ultrasonic motors.
NASA Astrophysics Data System (ADS)
Reaungamornrat, S.; Otake, Y.; Uneri, A.; Schafer, S.; Mirota, D. J.; Nithiananthan, S.; Stayman, J. W.; Khanna, A. J.; Reh, D. D.; Gallia, G. L.; Taylor, R. H.; Siewerdsen, J. H.
2012-02-01
Conventional surgical tracking configurations carry a variety of limitations in line-of-sight, geometric accuracy, and mismatch with the surgeon's perspective (for video augmentation). With increasing utilization of mobile C-arms, particularly those allowing cone-beam CT (CBCT), there is opportunity to better integrate surgical trackers at bedside to address such limitations. This paper describes a tracker configuration in which the tracker is mounted directly on the Carm. To maintain registration within a dynamic coordinate system, a reference marker visible across the full C-arm rotation is implemented, and the "Tracker-on-C" configuration is shown to provide improved target registration error (TRE) over a conventional in-room setup - (0.9+/-0.4) mm vs (1.9+/-0.7) mm, respectively. The system also can generate digitally reconstructed radiographs (DRRs) from the perspective of a tracked tool ("x-ray flashlight"), the tracker, or the C-arm ("virtual fluoroscopy"), with geometric accuracy in virtual fluoroscopy of (0.4+/-0.2) mm. Using a video-based tracker, planning data and DRRs can be superimposed on the video scene from a natural perspective over the surgical field, with geometric accuracy (0.8+/-0.3) pixels for planning data overlay and (0.6+/-0.4) pixels for DRR overlay across all C-arm angles. The field-of-view of fluoroscopy or CBCT can also be overlaid on real-time video ("Virtual Field Light") to assist C-arm positioning. The fixed transformation between the x-ray image and tracker facilitated quick, accurate intraoperative registration. The workflow and precision associated with a variety of realistic surgical tasks were significantly improved using the Tracker-on-C - for example, nearly a factor of 2 reduction in time required for C-arm positioning, reduction or elimination of dose in "hunting" for a specific fluoroscopic view, and confident placement of the x-ray FOV on the surgical target. The proposed configuration streamlines the integration of C-arm CBCT with realtime tracking and demonstrated utility in a spectrum of image-guided interventions (e.g., spine surgery) benefiting from improved accuracy, enhanced visualization, and reduced radiation exposure.
Faulkner, Austin R; Bourgeois, Austin C; Bradley, Yong C; Hudson, Kathleen B; Heidel, R Eric; Pasciak, Alexander S
2015-05-01
Fluoroscopically guided lumbar puncture (FGLP) is a commonly performed procedure with increased success rates relative to bedside technique. However, FGLP also exposes both patient and staff to ionizing radiation. The purpose of this study was to determine if the use of a simulation-based FGLP training program using an original, inexpensive lumbar spine phantom could improve operator confidence and efficiency, while also reducing patient dose. A didactic and simulation-based FGLP curriculum was designed, including a 1-hour lecture and hands-on training with a lumbar spine phantom prototype developed at our institution. Six incoming post-graduate year 2 (PGY-2) radiology residents completed a short survey before taking the course, and each resident practiced 20 simulated FGLPs using the phantom before their first clinical procedure. Data from the 114 lumbar punctures (LPs) performed by the six trained residents (prospective cohort) were compared to data from 514 LPs performed by 17 residents who did not receive simulation-based training (retrospective cohort). Fluoroscopy time (FT), FGLP success rate, and indication were compared. There was a statistically significant reduction in average FT for the 114 procedures performed by the prospective study cohort compared to the 514 procedures performed by the retrospective cohort. This held true for all procedures in aggregate, LPs for myelography, and all procedures performed for a diagnostic indication. Aggregate FT for the prospective group (0.87 ± 0.68 minutes) was significantly lower compared to the retrospective group (1.09 ± 0.65 minutes) and resulted in a 25% reduction in average FT (P = .002). There was no statistically significant difference in the number of failed FGLPs between the two groups. Our simulation-based FGLP curriculum resulted in improved operator confidence and reduced FT. These changes suggest that resident procedure efficiency was improved, whereas patient dose was reduced. The FGLP training program was implemented by radiology residents and required a minimal investment of time and resources. The LP spine phantom used during training was inexpensive, durable, and effective. In addition, the phantom is compatible with multiple modalities including fluoroscopy, computed tomography, and ultrasound and could be easily adapted to other applications such as facet injections or joint arthrograms. Copyright © 2015 AUR. Published by Elsevier Inc. All rights reserved.
Krebber, Anne-Marie H; van Uden-Kraan, Cornelia F; Melissant, Heleen C; Cuijpers, Pim; van Straten, Annemieke; Becker-Commissaris, Annemarie; Leemans, C René; Verdonck-de Leeuw, Irma M
2017-01-01
Recent results of a randomized clinical trial showed that a guided self-help intervention (based on problem-solving therapy) targeting psychological distress among head and neck cancer and lung cancer patients is effective. This study qualitatively explored motivation to start, experiences with and perceived outcomes of this intervention. Data were collected from semi-structured interviews of 16 patients. All interviews were audio-recorded and transcribed verbatim. Data were analyzed individually by two coders and coded into key issues and themes. Patients participated in the intervention for intrinsic (e.g. to help oneself) and for extrinsic reasons (e.g. being asked by a care professional or to help improve health care). Participants indicated positive and negative experiences with the intervention. Several participants appreciated participating as being a pleasant way to work on oneself, while others described participating as too confrontational. Some expressed their disappointment as they felt the intervention had brought them nothing or indicated that they felt worse temporarily, but most participants perceived positive outcomes of the intervention (e.g. feeling less distressed and having learned what matters in life). Cancer patients have various reasons to start a guided self-help intervention. Participants appreciated the guided self-help as intervention to address psychological distress, but there were also concerns. Most participants reported the intervention to be beneficial. The results suggest the need to identify patients who might benefit most from guided self-help targeting psychological distress and that interventions should be further tailored to individual cancer patients' requirements.
Image-guided elbow interventions: a literature review of interventional treatment options
Sorani, Alan
2016-01-01
Over the years, a wide range of image-guided interventional therapies have been used in treating different elbow pathologies, many of which are predominantly based on anecdotal and low-level study findings. This article critically assesses the existing literature and discusses the efficacy of the most commonly utilized interventional procedures for elbow pathology. PMID:26206415
Tulip deformity with Cera atrial septal defect devices: a report of 3 cases.
Kohli, Vikas
2015-02-01
Device closure of secundum atrial septal defect (ASD) is the treatment of choice when anatomy is favourable. Amplatzer device has remained the gold standard for closure of ASD. Cobra deformity is a well-reported problem with devices. Recently, Tulip deformity has been reported in a single case. We report a series of cases where we noted Tulip deformity along with inability to retract the device in the sheath in Cera Lifetech devices. This resulted in prolongation of procedure, excessive fluoroscopic exposure and additional interventional procedures not usually anticipated in ASD device closure. We believe that the problem is due to the stiffness of the device resulting in its inability to be retracted into the sheath. We also report a unique way of retrieving the device.
Fusion Imaging for Procedural Guidance.
Wiley, Brandon M; Eleid, Mackram F; Thaden, Jeremy J
2018-05-01
The field of percutaneous structural heart interventions has grown tremendously in recent years. This growth has fueled the development of new imaging protocols and technologies in parallel to help facilitate these minimally-invasive procedures. Fusion imaging is an exciting new technology that combines the strength of 2 imaging modalities and has the potential to improve procedural planning and the safety of many commonly performed transcatheter procedures. In this review we discuss the basic concepts of fusion imaging along with the relative strengths and weaknesses of static vs dynamic fusion imaging modalities. This review will focus primarily on echocardiographic-fluoroscopic fusion imaging and its application in commonly performed transcatheter structural heart procedures. Copyright © 2017 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.
Rigsby, Cynthia K; McKenney, Sarah E; Hill, Kevin D; Chelliah, Anjali; Einstein, Andrew J; Han, B Kelly; Robinson, Joshua D; Sammet, Christina L; Slesnick, Timothy C; Frush, Donald P
2018-01-01
Children with congenital or acquired heart disease can be exposed to relatively high lifetime cumulative doses of ionizing radiation from necessary medical imaging procedures including radiography, fluoroscopic procedures including diagnostic and interventional cardiac catheterizations, electrophysiology examinations, cardiac computed tomography (CT) studies, and nuclear cardiology examinations. Despite the clinical necessity of these imaging studies, the related ionizing radiation exposure could pose an increased lifetime attributable cancer risk. The Image Gently "Have-A-Heart" campaign is promoting the appropriate use of medical imaging studies in children with congenital or acquired heart disease while minimizing radiation exposure. The focus of this manuscript is to provide a comprehensive review of radiation dose management and CT performance in children with congenital or acquired heart disease.
2005-01-01
Medical technology is a fundamental instrument for the provision of health services in the Mexican Institute of Social Security (IMSS) and as a support for diagnostic and therapeutic interventions. The inventory of relevant medical equipment describes the needs for upgrading the technological infrastructure, organize its distribution and plan its renovation in order to guarantee the quality of health services. In this report we describe the type of equipment used in radiology and other imaging services, its geographical distribution, median age in operation and its productivity. The inventory reported 2091 pieces of equipment, ultrasonography and radiology were the most common types (31%) followed by fluoroscopic equipment (20%). Follow-up in the inventory should help in planning the acquisition and maintenance of sophisticated technology used for medical purposes.
Upper ankle joint space detection on low contrast intraoperative fluoroscopic C-arm projections
NASA Astrophysics Data System (ADS)
Thomas, Sarina; Schnetzke, Marc; Brehler, Michael; Swartman, Benedict; Vetter, Sven; Franke, Jochen; Grützner, Paul A.; Meinzer, Hans-Peter; Nolden, Marco
2017-03-01
Intraoperative mobile C-arm fluoroscopy is widely used for interventional verification in trauma surgery, high flexibility combined with low cost being the main advantages of the method. However, the lack of global device-to- patient orientation is challenging, when comparing the acquired data to other intrapatient datasets. In upper ankle joint fracture reduction accompanied with an unstable syndesmosis, a comparison to the unfractured contralateral site is helpful for verification of the reduction result. To reduce dose and operation time, our approach aims at the comparison of single projections of the unfractured ankle with volumetric images of the reduced fracture. For precise assessment, a pre-alignment of both datasets is a crucial step. We propose a contour extraction pipeline to estimate the joint space location for a prealignment of fluoroscopic C-arm projections containing the upper ankle joint. A quadtree-based hierarchical variance comparison extracts potential feature points and a Hough transform is applied to identify bone shaft lines together with the tibiotalar joint space. By using this information we can define the coarse orientation of the projections independent from the ankle pose during acquisition in order to align those images to the volume of the fractured ankle. The proposed method was evaluated on thirteen cadaveric datasets consisting of 100 projections each with manually adjusted image planes by three trauma surgeons. The results show that the method can be used to detect the joint space orientation. The correlation between angle deviation and anatomical projection direction gives valuable input on the acquisition direction for future clinical experiments.
Does fluoroscopy improve outcomes in paediatric forearm fracture reduction?
Menachem, S; Sharfman, Z T; Perets, I; Arami, A; Eyal, G; Drexler, M; Chechik, O
2016-06-01
To compare the radiographic results of paediatric forearm fracture reduced with and without fluoroscopic enhancement to investigate whether fractures reduced under fluoroscopic guidance would have smaller residual deformities and lower rates of re-reduction and surgery. A retrospective cohort analysis was conducted comparing paediatric patients with acute forearm fracture in two trauma centres. Demographics and radiographic data from paediatric forearm fractures treated in Trauma Centre A with the aid of a C-arm fluoroscopy were compared to those treated without fluoroscopy in Trauma Centre B. Re-reduction, late displacement, post-reduction deformity, and need for surgical intervention were compared between the two groups. The cohort included 229 children (175 boys and 54 girls, mean age 9.41±3.2 years, range 1-16 years) with unilateral forearm fractures (83 manipulated with fluoroscopy and 146 without). Thirty-four (15%) children underwent re-reduction procedures in the emergency department. Fifty-three (23%) children had secondary displacement in the cast, of which 18 were operated on, 20 were re-manipulated, and the remaining 15 were kept in the cast with an acceptable deformity. Twenty-nine additional children underwent operation for reasons other than secondary displacement. There were no significant differences in re-reduction and surgery rates or in post-reduction deformities between the two groups. The use of fluoroscopy during reduction of forearm fractures in the paediatric population apparently does not have a significant effect on patient outcomes. Reductions performed without fluoroscopy were comparably accurate in correcting deformities in both coronal and sagittal planes. Copyright © 2016 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
Improved-resolution real-time skin-dose mapping for interventional fluoroscopic procedures
NASA Astrophysics Data System (ADS)
Rana, Vijay K.; Rudin, Stephen; Bednarek, Daniel R.
2014-03-01
We have developed a dose-tracking system (DTS) that provides a real-time display of the skin-dose distribution on a 3D patient graphic during fluoroscopic procedures. Radiation dose to individual points on the skin is calculated using exposure and geometry parameters from the digital bus on a Toshiba C-arm unit. To accurately define the distribution of dose, it is necessary to use a high-resolution patient graphic consisting of a large number of elements. In the original DTS version, the patient graphics were obtained from a library of population body scans which consisted of larger-sized triangular elements resulting in poor congruence between the graphic points and the x-ray beam boundary. To improve the resolution without impacting real-time performance, the number of calculations must be reduced and so we created software-designed human models and modified the DTS to read the graphic as a list of vertices of the triangular elements such that common vertices of adjacent triangles are listed once. Dose is calculated for each vertex point once instead of the number of times that a given vertex appears in multiple triangles. By reformatting the graphic file, we were able to subdivide the triangular elements by a factor of 64 times with an increase in the file size of only 1.3 times. This allows a much greater number of smaller triangular elements and improves resolution of the patient graphic without compromising the real-time performance of the DTS and also gives a smoother graphic display for better visualization of the dose distribution.
Sawin, Kathleen J; Weiss, Marianne E; Johnson, Norah; Gralton, Karen; Malin, Shelly; Klingbeil, Carol; Lerret, Stacee M; Thompson, Jamie J; Zimmanck, Kim; Kaul, Molly; Schiffman, Rachel F
2017-03-01
Parents of hospitalized children, especially parents of children with complex and chronic health conditions, report not being adequately prepared for self-management of their child's care at home after discharge. No theory-based discharge intervention exists to guide pediatric nurses' preparation of parents for discharge. To develop a theory-based conversation guide to optimize nurses' preparation of parents for discharge and self-management of their child at home following hospitalization. Two frameworks and one method influenced the development of the intervention: the Individual and Family Self-Management Theory, Tanner's Model of Clinical Judgment, and the Teach-Back method. A team of nurse scientists, nursing leaders, nurse administrators, and clinical nurses developed and field tested the electronic version of a nine-domain conversation guide for use in acute care pediatric hospitals. The theory-based intervention operationalized self-management concepts, added components of nursing clinical judgment, and integrated the Teach-Back method. Development of a theory-based intervention, the translation of theoretical knowledge to clinical innovation, is an important step toward testing the effectiveness of the theory in guiding clinical practice. Clinical nurses will establish the practice relevance through future use and refinement of the intervention. © 2017 Sigma Theta Tau International.
Image fusion and navigation platforms for percutaneous image-guided interventions.
Rajagopal, Manoj; Venkatesan, Aradhana M
2016-04-01
Image-guided interventional procedures, particularly image guided biopsy and ablation, serve an important role in the care of the oncology patient. The need for tumor genomic and proteomic profiling, early tumor response assessment and confirmation of early recurrence are common scenarios that may necessitate successful biopsies of targets, including those that are small, anatomically unfavorable or inconspicuous. As image-guided ablation is increasingly incorporated into interventional oncology practice, similar obstacles are posed for the ablation of technically challenging tumor targets. Navigation tools, including image fusion and device tracking, can enable abdominal interventionalists to more accurately target challenging biopsy and ablation targets. Image fusion technologies enable multimodality fusion and real-time co-displays of US, CT, MRI, and PET/CT data, with navigational technologies including electromagnetic tracking, robotic, cone beam CT, optical, and laser guidance of interventional devices. Image fusion and navigational platform technology is reviewed in this article, including the results of studies implementing their use for interventional procedures. Pre-clinical and clinical experiences to date suggest these technologies have the potential to reduce procedure risk, time, and radiation dose to both the patient and the operator, with a valuable role to play for complex image-guided interventions.
Bennett, Sophie D; Coughtrey, Anna E; Heyman, Isobel; Greally, Suzanna; Clarkson, Harriet; Bhattacharyya, Tuhina; Lewis, Corah; Varadkar, Sophia; Shafran, Roz
2018-03-09
Children with neurological conditions such as epilepsy are at high risk of developing mental health disorders. Guided self-help can be used to increase access to psychological therapies. When developing and evaluating interventions, it is important to obtain the views of service-users about their acceptability. A telephone-guided self-help intervention was used to treat common mental health difficulties in children and young people with neurological conditions. The intervention was not adapted in content to account for chronic illness. This study therefore reports on qualitative interviews with participants to determine the acceptability of the intervention. Semi-structured interviews were conducted with 27 participants (25 parents and 2 young people) who had undertaken a telephone-delivered guided self-help intervention for common mental health difficulties in the context of a paediatric neurological condition. Transcripts were analysed thematically using the framework approach. Thirteen themes were extracted, organised into three main domains, which covered: the practicalities of telephone guided self-help treatment; the outcomes of the intervention; and the extent to which adaptation was needed for chronic illness. Most families found the intervention helpful in working towards their specific goals and noticed changes for the child and/or parents and family. Participants had a positive experience of the intervention and the majority of parents found the standard intervention with individualised goals sufficient to meet the young person's mental health needs. Copyright © 2018 European Paediatric Neurology Society. Published by Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Freitas, Ricardo Miguel Costa de, E-mail: ricardomcfreitas@gmail.com; Andrade, Celi Santos, E-mail: celis.andrade@hotmail.com; Caldas, José Guilherme Mendes Pereira, E-mail: jgmpcaldas@uol.com.br
PurposeThis study was designed to present the feasibility of an in vivo image-guided percutaneous cryoablation of the porcine vertebral body.MethodsThe institutional animal care committee approved this study. Cone-beam computed tomography (CBCT)-guided vertebral cryoablations (n = 22) were performed in eight pigs with short, 2-min, single or double-freezing protocols. Protective measures to nerves included dioxide carbon (CO{sub 2}) epidural injections and spinal canal temperature monitoring. Clinical, radiological, and pathological data with light (n = 20) or transmission electron (n = 2) microscopic analyses were evaluated after 6 days of clinical follow-up and euthanasia.ResultsCBCT/fluoroscopic-guided transpedicular vertebral body cryoprobe positioning and CO{sub 2} epidural injection were successful in all procedures. No majormore » complications were observed in seven animals (87.5 %, n = 8). A minor complication was observed in one pig (12.5 %, n = 1). Logistic regression model analysis showed the cryoprobe-spinal canal (Cp-Sc) distance as the most efficient parameter to categorize spinal canal temperatures lower than 19 °C (p < 0.004), with a significant Pearson’s correlation test (p < 0.041) between the Cp-Sc distance and the lowest spinal canal temperatures. Ablation zones encompassed pedicles and the posterior wall of the vertebral bodies with an inflammatory rim, although no inflammatory infiltrate was depicted in the surrounding neural structures at light microscopy. Ultrastructural analyses evidenced myelin sheath disruption in some large nerve fibers, although neurological deficits were not observed.ConclusionsCBCT-guided vertebral cryoablation of the porcine spine is feasible under a combination of a short freezing protocol and protective measures to the surrounding nerves. Ultrastructural analyses may be helpful assess the early modifications of the nerve fibers.« less
Attaluri, Anilchandra; Seshadri, Madhav; Mirpour, Sahar; Wabler, Michele; Marinho, Thomas; Furqan, Muhammad; Zhou, Haoming; De Paoli, Silvia; Gruettner, Cordula; Gilson, Wesley; DeWeese, Theodore; Garcia, Monica; Ivkov, Robert; Liapi, Eleni
2016-01-01
Purpose/objective The aim of this study was to develop and investigate the properties of a magnetic iron oxide nanoparticle–ethiodised oil formulation for image-guided thermal therapy of liver cancer. Materials and methods The formulation comprises bionised nano-ferrite (BNF) nanoparticles suspended in ethiodised oil, emulsified with polysorbate 20 (BNF-lip). Nanoparticle size was measured via photon correlation spectroscopy and transmission electron microscopy. In vivo thermal therapy capability was tested in two groups of male Foxn1nu mice bearing subcutaneous HepG2 xenograft tumours. Group I (n =12) was used to screen conditions for group II (n =48). In group II, mice received one of BNF-lip (n =18), BNF alone (n =16), or PBS (n =14), followed by alternating magnetic field (AMF) hyperthermia, with either varied duration (15 or 20 min) or amplitude (0, 16, 20, or 24 kA/m). Image-guided fluoroscopic intra-arterial injection of BNF-lip was tested in New Zealand white rabbits (n =10), bearing liver VX2 tumours. The animals were subsequently imaged with CT and 3 T MRI, up to 7 days post-injection. The tumours were histopathologically evaluated for distribution of BNF-lip. Results The BNF showed larger aggregate diameters when suspended in BNF-lip, compared to clear solution. The BNF-lip formulation produced maximum tumour temperatures with AMF >20 kA/m and showed positive X-ray visibility and substantial shortening of T1 and T2 relaxation time, with sustained intratumoural retention up to 7 days post-injection. On pathology, intratumoural BNF-lip distribution correlated well with CT imaging of intratumoural BNF-lip distribution. Conclusion The BNF-lip formulation has favourable thermal and dual imaging capabilities for image-guided thermal therapy of liver cancer, suggesting further exploration for clinical applications. PMID:27151045
Tandon, Vivek; Raheja, Amol; Suri, Ashish; Chandra, P Sarat; Kale, Shashank S; Kumar, Rajinder; Garg, Ajay; Kalaivani, Mani; Pandey, Ravindra M; Sharma, Bhawani S
2017-03-01
Till date there are no randomized trials to suggest the superiority of intra-operative magnetic resonance imaging (IOMRI) guided trans-sphenoidal pituitary resection over two dimensional fluoroscopic (2D-F) guided resections. We conducted this trial to establish the superiority of IOMRI in pituitary surgery. Primary objective was to compare extent of tumor resection between the two study arms. It was a prospective, randomized, outcome assessor and statistician blinded, two arm (A: IOMRI, n=25 and B: 2D-F, n=25), parallel group clinical trial. 4 patients from IOMRI group cross-over to 2D-F group and were consequently analyzed in latter group, based on modified intent to treat method. A total of 50 patients were enrolled till completion of trial (n=25 in each study arm). Demographic profile and baseline parameters were comparable among the two arms (p>0.05) except for higher number of endoscopic procedures and experienced neurosurgeons (>10years) in arm B (p=0.02, 0.002 respectively). Extent of resection was similar in both study arms (A, 94.9% vs B, 93.6%; p=0.78), despite adjusting for experience of operating surgeon and use of microscope/endoscope for surgical resection. We observed that use of IOMRI helped optimize the extent of resection in 5/20 patients (25%) for pituitary tumor resection in-group A. Present study failed to observe superiorty of IOMRI over conventional 2D-F guided resection in pituitary macroadenoma surgery. By use of this technology, younger surgeons could validate their results intra-operatively and hence could increase EOR without causing any increase in complications. Copyright © 2016 Elsevier Ltd. All rights reserved.
Cushman, Daniel; McCormick, Zachary; Casey, Ellen; Plastaras, Christopher T
2015-05-01
Pain intensity is commonly rated on an 11-point Numerical Pain Rating Scale which can be expressed as a calculated percentage pain reduction (CPPR), or by patient-reported percentage pain reduction (PRPPR). We aimed to determine the agreement between CPPR and PRPPR in quantifying musculoskeletal pain improvement at short-term follow-up after a corticosteroid injection. Retrospective cohort study. Urban, academic, physical medicine, and rehabilitation outpatient interventional musculoskeletal and spine center. The agreement between CPPR and PRPPR was determined by concordance correlation coefficient (CCC) in subjects who had experienced improvement in musculoskeletal or radicular pain 3 weeks after a first-time injection at our clinic. Subjects who experienced unchanged pain (PRPPR = 0) were compared to CPPR with paired t-test. We examined 197 subjects with greater than 3/10 pain who underwent first-time fluoroscopic-guided corticosteroid injections. Ninety-three subjects reported higher PRPPR than CPPR values, and 41 subjects reported higher CPPR values. The CCC between CPPR and PRPPR was 0.44 (95% CI 0.35-0.54), with a precision of 0.54 and an accuracy of 0.81, and 95% limits of agreement ranging between -41% and +73%. Values for CCC, precision, and accuracy were higher for males compared to females and were highest in the youngest age group (18-40) and lowest in the middle age group (41-60). PRPPR may not agree with CPPR at 3 week follow-up, as these individuals tend to report a higher estimated percentage improvement compared to the value calculated from their pain scores. Wiley Periodicals, Inc.
Fazeli, Roghayeh; Mohseni, Fatemeh; Hosseini, Seyedeh Esmat; Moghadasali, Reza; Mardpour, Soura; Azimian, Vajiheh; Ghorbani Liastani, Maede; Mirazimi Bafghi, Ali; Baghaban Eslaminejad, Mohamadreza; Aghdami, Nasser
2016-01-01
Objective Nonunion is defined as a minimum of 9 months since injury without any visible progressive signs of healing for 3 months. Recent literature has shown that the application of mesenchymal stromal cells is safe, in vitro and in vivo, for treating long bone nonunion. The present study was performed to investigate the safety of mesenchymal stromal cell (MSC) implantation in combination with platelet lysate (PL) product for treating human long bone nonunion. Materials and Methods In this case series clinical trial, orthopedic surgeons visited eighteen patients with long bone nonunion, of whom 7 complied with the eligibility criteria. These patients received mesenchymal stromal cells (20 million cells implanted once into the nonunion site using a fluoroscopic guide) in combination with PL product. For evaluation of the effects of this intervention all the patients were followed up by taking anterior-posterior and lateral X-rays of the affected limb before and 1, 3, 6, and 12 months after the implantation. All side effects (local or systemic, serious or non-serious, related or unrelated) were observed during this time period. Results From a safety perspective the MSC implantation in combination with PL was very well tolerated during the 12 months of the trial. Four patients were healed; based on the control Xray evidence, bony union had occurred. Conclusion Results from the present study suggest that the implantation of bone marrow-derived MSCs in combination with PL is safe for the treatment of nonunion. A double blind, controlled clinical trial is required to assess the efficacy of this treatment (Registration Number: NCT01206179). PMID:27602311
Graphical User Interface for a Dual-Module EMCCD X-ray Detector Array.
Wang, Weiyuan; Ionita, Ciprian; Kuhls-Gilcrist, Andrew; Huang, Ying; Qu, Bin; Gupta, Sandesh K; Bednarek, Daniel R; Rudin, Stephen
2011-03-16
A new Graphical User Interface (GUI) was developed using Laboratory Virtual Instrumentation Engineering Workbench (LabVIEW) for a high-resolution, high-sensitivity Solid State X-ray Image Intensifier (SSXII), which is a new x-ray detector for radiographic and fluoroscopic imaging, consisting of an array of Electron-Multiplying CCDs (EMCCDs) each having a variable on-chip electron-multiplication gain of up to 2000× to reduce the effect of readout noise. To enlarge the field-of-view (FOV), each EMCCD sensor is coupled to an x-ray phosphor through a fiberoptic taper. Two EMCCD camera modules are used in our prototype to form a computer-controlled array; however, larger arrays are under development. The new GUI provides patient registration, EMCCD module control, image acquisition, and patient image review. Images from the array are stitched into a 2k×1k pixel image that can be acquired and saved at a rate of 17 Hz (faster with pixel binning). When reviewing the patient's data, the operator can select images from the patient's directory tree listed by the GUI and cycle through the images using a slider bar. Commonly used camera parameters including exposure time, trigger mode, and individual EMCCD gain can be easily adjusted using the GUI. The GUI is designed to accommodate expansion of the EMCCD array to even larger FOVs with more modules. The high-resolution, high-sensitivity EMCCD modular-array SSXII imager with the new user-friendly GUI should enable angiographers and interventionalists to visualize smaller vessels and endovascular devices, helping them to make more accurate diagnoses and to perform more precise image-guided interventions.
McCabe, Bradley P.; Speidel, Michael A.; Pike, Tina L.; Van Lysel, Michael S.
2011-01-01
Purpose: In this study, newly formulated XR-RV3 GafChromic® film was calibrated with National Institute of Standards and Technology (NIST) traceability for measurement of patient skin dose during fluoroscopically guided interventional procedures. Methods: The film was calibrated free-in-air to air kerma levels between 15 and 1100 cGy using four moderately filtered x-ray beam qualities (60, 80, 100, and 120 kVp). The calibration films were scanned with a commercial flatbed document scanner. Film reflective density-to-air kerma calibration curves were constructed for each beam quality, with both the orange and white sides facing the x-ray source. A method to correct for nonuniformity in scanner response (up to 25% depending on position) was developed to enable dose measurement with large films. The response of XR-RV3 film under patient backscattering conditions was examined using on-phantom film exposures and Monte Carlo simulations. Results: The response of XR-RV3 film to a given air kerma depended on kVp and film orientation. For a 200 cGy air kerma exposure with the orange side of the film facing the source, the film response increased by 20% from 60 to 120 kVp. At 500 cGy, the increase was 12%. When 500 cGy exposures were performed with the white side facing the x-ray source, the film response increased by 4.0% (60 kVp) to 9.9% (120 kVp) compared to the orange-facing orientation. On-phantom film measurements and Monte Carlo simulations show that using a NIST-traceable free-in-air calibration curve to determine air kerma in the presence of backscatter results in an error from 2% up to 8% depending on beam quality. The combined uncertainty in the air kerma measurement from the calibration curves and scanner nonuniformity correction was ±7.1% (95% C.I.). The film showed notable stability. Calibrations of film and scanner separated by 1 yr differed by 1.0%. Conclusions: XR-RV3 radiochromic film response to a given air kerma shows dependence on beam quality and film orientation. The presence of backscatter slightly modifies the x-ray energy spectrum; however, the increase in film response can be attributed primarily to the increase in total photon fluence at the sensitive layer. Film calibration curves created under free-in-air conditions may be used to measure dose from fluoroscopic quality x-ray beams, including patient backscatter with an error less than the uncertainty of the calibration in most cases. PMID:21626925
Three-Station Three-dimensional Bolus-Chase MR Angiography with Real-time Fluoroscopic Tracking
Johnson, Casey P.; Weavers, Paul T.; Borisch, Eric A.; Grimm, Roger C.; Hulshizer, Thomas C.; LaPlante, Christine C.; Rossman, Phillip J.; Glockner, James F.; Young, Phillip M.
2014-01-01
Purpose To determine the feasibility of using real-time fluoroscopic tracking for bolus-chase magnetic resonance (MR) angiography of peripheral vasculature to image three stations from the aortoiliac bifurcation to the pedal arteries. Materials and Methods This prospective study was institutional review board approved and HIPAA compliant. Eight healthy volunteers (three men; mean age, 48 years; age range, 30–81 years) and 13 patients suspected of having peripheral arterial disease (five men; mean age, 67 years; age range, 47–81 years) were enrolled and provided informed consent. All subjects were imaged with the fluoroscopic tracking MR angiographic protocol. Ten patients also underwent a clinical computed tomographic (CT) angiographic runoff examination. Two readers scored the MR angiographic studies for vessel signal intensity and sharpness and presence of confounding artifacts and venous contamination at 35 arterial segments. Mean aggregate scores were assessed. The paired MR angiographic and CT angiographic studies also were scored for visualization of disease, reader confidence, and overall diagnostic quality and were compared by using a Wilcoxon signed rank test. Results Real-time fluoroscopic tracking performed well technically in all studies. Vessel segments were scored good to excellent in all but the following categories: For vessel signal intensity and sharpness, the abdominal aorta, iliac arteries, distal plantar arteries, and plantar arch were scored as fair to good; and for presence of confounding artifacts, the abdominal aorta and iliac arteries were scored as fair. The MR angiograms and CT angiograms did not differ significantly in any scoring category (reader 1: P = .50, .39, and .39; reader 2: P = .41, .61, and .33, respectively). CT scores were substantially better in 20% (four of 20) and 25% (five of 20) of the pooled evaluations for the visualization of disease and overall image quality categories, respectively, versus 5% (one of 20) for MR scores in both categories. Conclusion Three-station bolus-chase MR angiography with real-time fluoroscopic tracking provided high-spatial-resolution arteriograms of the peripheral vasculature, enabled precise triggering of table motion, and compared well with CT angiograms. © RSNA, 2014 Online supplemental material is available for this article. PMID:24635676
DOE Office of Scientific and Technical Information (OSTI.GOV)
Paik, Nam Chull, E-mail: pncspine@gmail.com
2016-07-15
PurposeA technique for computed tomography fluoroscopy (CTF)-guided intraarticular (IA) sacroiliac joint (SIJ) injection was devised to limit procedural time and radiation dose.MethodsOur Institutional Review Board approved this retrospective analysis and waived the requirement for informed consent. Overall, 36 consecutive diagnostic or therapeutic IA SIJ injections (unilateral, 20; bilateral, 16) performed in 34 patients (female, 18; male, 16) with a mean age of 45.5 years (range 20–76 years) under CTF guidance were analyzed, assessing technical success (i.e., IA contrast spread), procedural time, and radiation dose.ResultsAll injections were successful from a technical perspective and were free of serious complications. Respective median proceduralmore » times and effective doses of SIJ injection were as follows: unilateral, 5.28 min (range 3.58–8.00 min) and 0.11 millisievert (mSv; range 0.07–0.24 mSv); and bilateral, 6.72 min (range 4.17–21.17 min) and 0.11 mSv (range 0.09–0.51 mSv).ConclusionsGiven the high rate of technical success achieved in limited time duration and with little radiation exposure, CTF-guided IA SIJ injection is a practical and low-risk procedure.« less
Graham, D Y; Smith, J L
1985-06-01
Balloon esophageal dilatation offers many theoretical advantages (safety, speed, and patient comfort) over dilatation with mercury-filled bougies or with the Eder-Puestow system. The authors used balloon dilators in 22 patients with dysphagia secondary to benign or malignant strictures. Dilatation was performed with fluoroscopic guidance, blindly, or by a combination of these techniques. For "blind" stricture dilatation, an Eder-Puestow spring-tipped guide wire is placed into the stomach using a fiberoptic endoscope. The distance from the incisor teeth to the stricture is measured, and the balloon shaft is marked to indicate when the middle of the balloon is within the stricture. Dilatation is then performed using the antegrade or, the preferred, retrograde technique. Finally, the dilated stricture is calibrated by pulling an inflated balloon through the previously strictured area without difficulty. An attempt was made to achieve an esophageal diameter of 15 mm at the initial dilatation episode, and patient discomfort was used as a guide as to the final diameter. The balloon dilatation technique was highly successful, and a stricture diameter of 15 mm (45-47 French) was achieved at the initial dilatation in most instances. Malignant strictures were easily dilated. Balloon dilatation is convenient, effective, quick, and potentially safer than the previous Eder-Puestow or mercury-filled bougie techniques.
Esposito, Francesco; Ambrosio, Concetta; De Fronzo, Simona; Panico, Maria Rita; D'Aprano, Marilena; Giugliano, Anna Marcella; Noviello, Domenico; Oresta, Patrizia
2015-06-01
Intussusception is one of the most common causes of paediatric emergency. Fluoroscopy-guided hydrostatic reduction is a common nonoperative management strategy for the treatment of intussusception. The role of pharmacological premedication in increasing the success rate of hydrostatic reduction is still controversial. The purpose of this study was to verify the presence of a possible correlation between pharmacological premedication and the percentage of hydrostatic reduction of intussusception in paediatric patients. This study considered children with a diagnosis of idiopathic intussusception treated at our hospital between January 2007 and June 2013. One group of patients underwent hydrostatic reduction by barium enema without any preliminary therapy. A second group of patients received pharmacological premedication with both a sedative and an anti-oedematous agent before the procedure. A total of 398 patients were treated with barium enema for therapeutic purposes. In the group of patients who received no premedication (n = 254), 165 (65 %) children achieved hydrostatic reduction of the intussusception. Among the patients who received pharmacological premedication prior to barium enema (n = 144), 122 (85 %) children achieved resolution of the intussusception. Our study shows that the use of pharmacological premedication is effective for the reduction of the intussusception, as its limit patient stress, fluoroscopic time and radiation dose.
Mori, S
2014-05-01
To ensure accuracy in respiratory-gating treatment, X-ray fluoroscopic imaging is used to detect tumour position in real time. Detection accuracy is strongly dependent on image quality, particularly positional differences between the patient and treatment couch. We developed a new algorithm to improve the quality of images obtained in X-ray fluoroscopic imaging and report the preliminary results. Two oblique X-ray fluoroscopic images were acquired using a dynamic flat panel detector (DFPD) for two patients with lung cancer. The weighting factor was applied to the DFPD image in respective columns, because most anatomical structures, as well as the treatment couch and port cover edge, were aligned in the superior-inferior direction when the patient lay on the treatment couch. The weighting factors for the respective columns were varied until the standard deviation of the pixel values within the image region was minimized. Once the weighting factors were calculated, the quality of the DFPD image was improved by applying the factors to multiframe images. Applying the image-processing algorithm produced substantial improvement in the quality of images, and the image contrast was increased. The treatment couch and irradiation port edge, which were not related to a patient's position, were removed. The average image-processing time was 1.1 ms, showing that this fast image processing can be applied to real-time tumour-tracking systems. These findings indicate that this image-processing algorithm improves the image quality in patients with lung cancer and successfully removes objects not related to the patient. Our image-processing algorithm might be useful in improving gated-treatment accuracy.
Dosimetry during intramedullary nailing of the tibia
2009-01-01
Background Intramedullary nailing under fluoroscopic guidance is a common operation. We studied the intraoperative radiation dose received by both the patient and the personnel. Patients and methods 25 intramedullary nailing procedures of the tibia were studied. All patients suffered from tibial fractures and were treated using the Grosse-Kempf intramedullary nail, with free-hand technique for fixation of the distal screws, under fluoroscopic guidance. The exposure, at selected positions, was recorded using an ion chamber, while the dose area product (DAP) was measured with a DAP meter, attached to the tube head. Thermoluminescent dosimeters (TLDs) were used to derive the occupational dose to the personnel, and also to monitor the surface dose on the gonads of some of the patients. Results The mean operation time was 101 (48–240) min, with a mean fluoroscopic time of 72 seconds and a mean DAP value of 75 cGy·cm2. The surface dose to the gonads of the patients was less than 8.8 mGy during any procedure, and thus cannot be considered to be a contraindication for the use of this technique. Occupational dose differed substantially between members of the operating personnel, the maximum dose recorded being to the operator of the fluoroscopic equipment (0.11 mSv). Interpretation Our findings underscore the care required by the primary operator not to exceed the dose constraint of 10 mSv per year. The rest of the operating personnel, although they do not receive very high doses, should focus on the dose optimization of the technique. PMID:19916691
Connecting: A Resource Guide for the Primary Intervention Program.
ERIC Educational Resources Information Center
Prusso, Laurie Kay
This thesis is the result of a study to develop and evaluate a resource guide for use by paraprofessionals implementing the Primary Intervention Program (PIP) in public school settings. PIP is used to detect and prevent school adjustment problems in primary school students through observations of their play behaviors. The resource guide was…
Fostering First Graders' Reasoning Strategies with Basic Sums: The Value of Guided Instruction
ERIC Educational Resources Information Center
Purpura, David J.; Baroody, Arthur J.; Eiland, Michael D.; Reid, Erin E.
2016-01-01
An intervention experiment served to evaluate the efficacy of highly guided discovery learning of relations underlying add-1 and doubles combination families and to compare the impact of such instruction with minimally guided instruction. After a pretest, 78 first graders were randomly assigned to one of three intervention conditions: highly…
ERIC Educational Resources Information Center
Dunst, Carl J.
2017-01-01
Findings from three field tests evaluations of early childhood intervention practitioner performance checklists and three parent practice guides are reported. Forty-two practitioners from three early childhood intervention programs reviewed the checklists and practice guides and made (1) social validity judgments of both products, (2) judgments of…
Motion-adapted catheter navigation with real-time instantiation and improved visualisation
Kwok, Ka-Wai; Wang, Lichao; Riga, Celia; Bicknell, Colin; Cheshire, Nicholas; Yang, Guang-Zhong
2014-01-01
The improvements to catheter manipulation by the use of robot-assisted catheter navigation for endovascular procedures include increased precision, stability of motion and operator comfort. However, navigation through the vasculature under fluoroscopic guidance is still challenging, mostly due to physiological motion and when tortuous vessels are involved. In this paper, we propose a motion-adaptive catheter navigation scheme based on shape modelling to compensate for these dynamic effects, permitting predictive and dynamic navigations. This allows for timed manipulations synchronised with the vascular motion. The technical contribution of the paper includes the following two aspects. Firstly, a dynamic shape modelling and real-time instantiation scheme based on sparse data obtained intra-operatively is proposed for improved visualisation of the 3D vasculature during endovascular intervention. Secondly, a reconstructed frontal view from the catheter tip using the derived dynamic model is used as an interventional aid to user guidance. To demonstrate the practical value of the proposed framework, a simulated aortic branch cannulation procedure is used with detailed user validation to demonstrate the improvement in navigation quality and efficiency. PMID:24744817
1991-07-31
My first thought when I began to read the Nurse's Pocket Guide: Nursing Diagnoses with Interventions was 'at last, a nursing dictionary instead of the usual medical dictionary for nurses!' Unfortunately, it did not live up to my expectations. The book starts out with a good idea but, like so many others, fails to communicate it effectively and simply.
Safari, Mohammad Javad; Wong, Jeannie Hsiu Ding; Jong, Wei Loong; Thorpe, Nathan; Cutajar, Dean; Rosenfeld, Anatoly; Ng, Kwan Hoong
2017-03-01
The purpose of this study was to investigate the effects of routine exposure parameters on patient's dose during neuro-interventional radiology procedures. We scrutinized the routine radiological exposure parameters during 58 clinical neuro-interventional procedures such as, exposure direction, magnification, frame rate, and distance between image receptor to patient's body and evaluate their effects on patient's dose using an anthropomorphic phantom. Radiation dose received by the occipital region, ears and eyes of the phantom were measured using MOSkin detectors. DSA imaging technique is a major contributor to patient's dose (80.9%) even though they are used sparingly (5.3% of total frame number). The occipital region of the brain received high dose largely from the frontal tube constantly placed under couch (73.7% of the total KAP). When rotating the frontal tube away from under the couch, the radiation dose to the occipital reduced by 40%. The use of magnification modes could increase radiation dose by 94%. Changing the image receptor to the phantom surface distance from 10 to 40cm doubled the radiation dose received by the patient's skin at the occipital region. Our findings provided important insights into the contribution of selected fluoroscopic exposure parameters and their impact on patient's dose during neuro-interventional radiology procedures. This study showed that the DSA imaging technique contributed to the highest patient's dose and judicial use of exposure parameters might assist interventional radiologists in effective skin and eye lens dose reduction for patients undergoing neuro-interventional procedures. Copyright © 2017 Associazione Italiana di Fisica Medica. All rights reserved.
ICRP publication 121: radiological protection in paediatric diagnostic and interventional radiology.
Khong, P-L; Ringertz, H; Donoghue, V; Frush, D; Rehani, M; Appelgate, K; Sanchez, R
2013-04-01
Paediatric patients have a higher average risk of developing cancer compared with adults receiving the same dose. The longer life expectancy in children allows more time for any harmful effects of radiation to manifest, and developing organs and tissues are more sensitive to the effects of radiation. This publication aims to provide guiding principles of radiological protection for referring clinicians and clinical staff performing diagnostic imaging and interventional procedures for paediatric patients. It begins with a brief description of the basic concepts of radiological protection, followed by the general aspects of radiological protection, including principles of justification and optimisation. Guidelines and suggestions for radiological protection in specific modalities - radiography and fluoroscopy, interventional radiology, and computed tomography - are subsequently covered in depth. The report concludes with a summary and recommendations. The importance of rigorous justification of radiological procedures is emphasised for every procedure involving ionising radiation, and the use of imaging modalities that are non-ionising should always be considered. The basic aim of optimisation of radiological protection is to adjust imaging parameters and institute protective measures such that the required image is obtained with the lowest possible dose of radiation, and that net benefit is maximised to maintain sufficient quality for diagnostic interpretation. Special consideration should be given to the availability of dose reduction measures when purchasing new imaging equipment for paediatric use. One of the unique aspects of paediatric imaging is with regards to the wide range in patient size (and weight), therefore requiring special attention to optimisation and modification of equipment, technique, and imaging parameters. Examples of good radiographic and fluoroscopic technique include attention to patient positioning, field size and adequate collimation, use of protective shielding, optimisation of exposure factors, use of pulsed fluoroscopy, limiting fluoroscopy time, etc. Major paediatric interventional procedures should be performed by experienced paediatric interventional operators, and a second, specific level of training in radiological protection is desirable (in some countries, this is mandatory). For computed tomography, dose reduction should be optimised by the adjustment of scan parameters (such as mA, kVp, and pitch) according to patient weight or age, region scanned, and study indication (e.g. images with greater noise should be accepted if they are of sufficient diagnostic quality). Other strategies include restricting multiphase examination protocols, avoiding overlapping of scan regions, and only scanning the area in question. Up-to-date dose reduction technology such as tube current modulation, organ-based dose modulation, auto kV technology, and iterative reconstruction should be utilised when appropriate. It is anticipated that this publication will assist institutions in encouraging the standardisation of procedures, and that it may help increase awareness and ultimately improve practices for the benefit of patients. Copyright © 2012. Published by Elsevier Ltd.
Moreno-Domínguez, Silvia; Rodríguez-Ruiz, Sonia; Fernández-Santaella, M Carmen; Jansen, Anita; Tuschen-Caffier, Brunna
2012-03-01
While effectiveness of mirror exposure to reduce body dissatisfaction has been demonstrated, the exposure was almost always combined with other interventions. The aim of the study was to evaluate the effectiveness of a pure mirror exposure intervention compared with a guided mirror exposure (participants are guided to describe their body shape in a non-evaluative manner) and an imagery exposure intervention (participants are guided to describe their body through mental representation). Thirty-one women with high body dissatisfaction received five sessions of treatment under one of the three conditions. All interventions reduced body dissatisfaction, but only the mirror exposures successfully reduced the frequency of negative thoughts and feelings of ugliness. Pure mirror exposure was more effective than guided exposure for reducing body discomfort within and between sessions. Pure mirror exposure, based on the traditional extinction paradigm, led to strong emotional activation followed by a fast decrease in emotional reactivity. Copyright © 2011 Elsevier Ltd. All rights reserved.
Noriega, David C; Hernández-Ramajo, Rubén; Rodríguez-Monsalve Milano, Fiona; Sanchez-Lite, Israel; Toribio, Borja; Ardura, Francisco; Torres, Ricardo; Corredera, Raul; Kruger, Antonio
2017-01-01
Pedicle screws in spinal surgery have allowed greater biomechanical stability and higher fusion rates. However, malposition is very common and may cause neurologic, vascular, and visceral injuries and compromise mechanical stability. The purpose of this study was to compare the malposition rate between intraoperative computed tomography (CT) scan assisted-navigation and free-hand fluoroscopy-guided techniques for placement of pedicle screw instrumentation. This is a prospective, randomized, observational study. A total of 114 patients were included: 58 in the assisted surgery group and 56 in the free-hand fluoroscopy-guided surgery group. Analysis of screw position was assessed using the Heary classification. Breach severity was defined according to the Gertzbein classification. Radiation doses were evaluated using thermoluminescent dosimeters, and estimates of effective and organ doses were made based on scan technical parameters. Consecutive patients with degenerative disease, who underwent surgical procedures using the free-hand, or intraoperative navigation technique for placement of transpedicular instrumentation, were included in the study. Forty-four out of 625 implanted screws were malpositioned: 11 (3.6%) in the navigated surgery group and 33 (10.3%) in the free-hand group (p<.001). Screw position according to the Heary scale was Grade II (4 navigated surgery, 6 fluoroscopy guided), Grade III (3 navigated surgery, 11 fluoroscopy guided), Grade IV (4 navigated surgery, 16 fluoroscopy guided), and Grade V (1 fluoroscopy guided). There was only one symptomatic case in the conventional surgery group. Breach severity was seven Grade A and four Grade B in the navigated surgery group, and eight Grade A, 24 Grade B, and one Grade C in free-hand fluoroscopy-guided surgery group. Radiation received per patient was 5.8 mSv (4.8-7.3). The median dose received in the free-hand fluoroscopy group was 1 mGy (0.8-1.1). There was no detectable radiation level in the navigation-assisted surgery group, whereas the effective dose was 10 µGy in the free-hand fluoroscopy-guided surgery group. Malposition rate, both symptomatic and asymptomatic, in spinal surgery is reduced when using CT-guided placement of transpedicular instrumentation compared with placement under fluoroscopic guidance, with radiation values within the safety limits for health. Larger studies are needed to determine risk-benefit in these patients. Copyright © 2016 Elsevier Inc. All rights reserved.
Radiation Dose Optimization For Critical Organs
NASA Astrophysics Data System (ADS)
Khodadadegan, Yasaman
Ionizing radiation used in the patient diagnosis or therapy has negative effects on the patient body in short term and long term depending on the amount of exposure. More than 700,000 examinations are everyday performed on Interventional Radiology modalities, however; there is no patient-centric information available to the patient or the Quality Assurance for the amount of organ dose received. In this study, we are exploring the methodologies to systematically reduce the absorbed radiation dose in the Fluoroscopically Guided Interventional Radiology procedures. In the first part of this study, we developed a mathematical model which determines a set of geometry settings for the equipment and a level for the energy during a patient exam. The goal is to minimize the amount of absorbed dose in the critical organs while maintaining image quality required for the diagnosis. The model is a large-scale mixed integer program. We performed polyhedral analysis and derived several sets of strong inequalities to improve the computational speed and quality of the solution. Results present the amount of absorbed dose in the critical organ can be reduced up to 99% for a specific set of angles. In the second part, we apply an approximate gradient method to simultaneously optimize angle and table location while minimizing dose in the critical organs with respect to the image quality. In each iteration, we solve a sub-problem as a MIP to determine the radiation field size and corresponding X-ray tube energy. In the computational experiments, results show further reduction (up to 80%) of the absorbed dose in compare with previous method. Last, there are uncertainties in the medical procedures resulting imprecision of the absorbed dose. We propose a robust formulation to hedge from the worst case absorbed dose while ensuring feasibility. In this part, we investigate a robust approach for the organ motions within a radiology procedure. We minimize the absorbed dose for the critical organs across all input data scenarios which are corresponding to the positioning and size of the organs. The computational results indicate up to 26% increase in the absorbed dose calculated for the robust approach which ensures the feasibility across scenarios.
Luani, Blerim; Zrenner, Bernhard; Basho, Maksim; Genz, Conrad; Rauwolf, Thomas; Tanev, Ivan; Schmeisser, Alexander; Braun-Dullaeus, Rüdiger C
2018-01-01
Stochastic damage of the ionizing radiation to both patients and medical staff is a drawback of fluoroscopic guidance during catheter ablation of cardiac arrhythmias. Therefore, emerging zero-fluoroscopy catheter-guidance techniques are of great interest. We investigated, in a prospective pilot study, the feasibility and safety of the cryothermal (CA) slow-pathway ablation in patients with symptomatic atrioventricular-nodal-re-entry-tachycardia (AVNRT) using solely intracardiac echocardiography (ICE) for endovascular and endocardial catheter visualization. Twenty-five consecutive patients (mean age 55.6 ± 12.0 years, 17 female) with ECG-documentation or symptoms suggesting AVNRT underwent an electrophysiology study (EPS) in our laboratory utilizing ICE for catheter navigation. Supraventricular tachycardia was inducible in 23 (92%) patients; AVNRT was confirmed by appropriate stimulation maneuvers in 20 (80%) patients. All EPS in the AVNRT subgroup could be accomplished without need for fluoroscopy, relying solely on ICE-guidance. CA guided by anatomical location and slow-pathway potentials was successful in all patients, median cryo-mappings = 6 (IQR:3-10), median cryo-ablations = 2 (IQR:1-3). Fluoroscopy was used to facilitate the trans-septal puncture and localization of the ablation substrate in the remaining 3 patients (one focal atrial tachycardia and two atrioventricular-re-entry-tachycardias). Mean EPS duration in the AVNRT subgroup was 99.8 ± 39.6 minutes, ICE guided catheter placement 11.9 ± 5.8 minutes, time needed for diagnostic evaluation 27.1 ± 10.8 minutes, and cryo-application duration 26.3 ± 30.8 minutes. ICE-guided zero-fluoroscopy CA in AVNRT patients is feasible and safe. Real-time visualization of the true endovascular borders and cardiac structures allow for safe catheter navigation during the ICE-guided EPS and might be an alternative to visualization technologies using geometry reconstructions. © 2017 Wiley Periodicals, Inc.
The Use of Guided Imagery as an Intervention in Addressing Nonsuicidal Self-Injury
ERIC Educational Resources Information Center
Kress, Victoria E.; Adamson, Nicole; DeMarco, Carrie; Paylo, Matthew J.; Zoldan, Chelsey A.
2013-01-01
This article presents guided imagery as an intervention that can be used to address clients' nonsuicidal self-injurious behaviors. Guided imagery is a behavioral therapy technique that involves the use of positive thoughts or images to regulate negative emotional experiences, and it can be used to prevent and manage impulses to self-injure.…
Fluoroscopic tomography. [for body section synthesis
NASA Technical Reports Server (NTRS)
Baily, N. A.; Crepeau, R. L.; Lasser, E. C.
1974-01-01
A fluoroscopic tomography system capable of synthesizing body sections at a number of levels within the body has been developed. The synthesized body sections may lie either in a range of planes parallel to, tilted with respect to, skewed with respect to, or both tilted and skewed with respect to the plane of motion of the X-ray tube target. In addition, body sections can be presented which are contoured to the patient's anatomy. That is to say, they may even encompass such complex surfaces as a quadratic hyperplane. In addition, tomograms of organs in motion can be imaged.
The Guide to Community Preventive Services and Disability Inclusion.
Hinton, Cynthia F; Kraus, Lewis E; Richards, T Anne; Fox, Michael H; Campbell, Vincent A
2017-12-01
Approximately 40 million people in the U.S. identify as having a serious disability, and people with disabilities experience many health disparities compared with the general population. The Guide to Community Preventive Services (The Community Guide) identifies evidence-based programs and policies recommended by the Community Preventive Services Task Force (Task Force) to promote health and prevent disease. The Community Guide was assessed to answer the questions: are Community Guide public health intervention recommendations applicable to people with disabilities, and are adaptations required? An assessment of 91 recommendations from The Community Guide was conducted for 15 health topics by qualitative analysis involving three data approaches: an integrative literature review (years 1980-2011), key informant interviews, and focus group discussion during 2011. Twenty-six recommended interventions would not need any adaptation to be of benefit to people with disabilities. Forty-one recommended interventions could benefit from adaptations in communication and technology; 33 could benefit from training adaptations; 31 from physical accessibility adaptations; and 16 could benefit from other adaptations, such as written policy changes and creation of peer support networks. Thirty-eight recommended interventions could benefit from one or more adaptations to enhance disability inclusion. As public health and healthcare systems implement Task Force recommendations, identifying and addressing barriers to full participation for people with disabilities is important so that interventions reach the entire population. With appropriate adaptations, implementation of recommendations from The Community Guide could be successfully expanded to address the needs of people with disabilities. Published by Elsevier Inc.
Ezenwa, Miriam O; Yao, Yingwei; Engeland, Christopher G; Molokie, Robert E; Wang, Zaijie Jim; Suarez, Marie L; Wilkie, Diana J
2016-06-01
To test feasibility of a guided audio-visual relaxation intervention protocol for reducing stress and pain in adults with sickle cell disease. Sickle cell pain is inadequately controlled using opioids, necessitating further intervention such as guided relaxation to reduce stress and pain. Attention-control, randomized clinical feasibility pilot study with repeated measures. Randomized to guided relaxation or control groups, all patients recruited between 2013-2014 during clinical visits, completed stress and pain measures via a Galaxy Internet-enabled Android tablet at the Baseline visit (pre/post intervention), 2-week posttest visit and also daily at home between the two visits. Experimental group patients were asked to use a guided relaxation intervention at the Baseline visit and at least once daily for 2 weeks. Control group patients engaged in a recorded sickle cell discussion at the Baseline visit. Data were analysed using linear regression with bootstrapping. At baseline, 27/28 of consented patients completed the study protocol. Group comparison showed that guided relaxation significantly reduced current stress and pain. At the 2-week posttest, 24/27 of patients completed the study, all of whom reported liking the study. Patients completed tablet-based measures on 71% of study days (69% in control group, 72% in experiment group). At the 2-week posttest, the experimental group had significantly lower composite pain index scores, but the two groups did not differ significantly on stress intensity. This study protocol appears feasible. The tablet-based guided relaxation intervention shows promise for reducing sickle cell pain and warrants a larger efficacy trial. The ClinicalTrials.gov Identifier is: NCT02501447. © 2016 John Wiley & Sons Ltd.
Study guides: effective tools to improve self-directed learning skills of medical students.
Khabaz Mafinejad, Mahboobeh; Aghili, Rokhsareh; Emami, Zahra; Malek, Mojtaba; Baradaran, Hamidreza; Taghavinia, Mansoureh; Khamseh, Mohammad E
2014-01-01
In medicine, there is a rapid development of a knowledge base. Medical professionals need to sustain and advance their competence to practice in response to these varieties. So, there is increased interest in self-directed learning methods. Study guides can make a major contribution to self-directed learning. This study was carried out to evaluate the effect of study guides on improving self-learning skills of medical students in the Iran University of Medical Sciences (IUMS). In this quasi-experimental study, 46 medical students were randomly assigned into two groups; the intervention group and the control group. Both groups participated in a diagnostic test at the beginning of the course (pre-test). The same test was taken at the end of the course (post-test). The intervention group was provided with study guides on thyroid disorders and diabetes. Meanwhile, they continued their routine clinical training. The control group was only involved in the conventional training program. Students in the intervention group were also asked to complete a designed questionnaire in regard to their attitude toward the study guides. At enrollment, there was no statistically significant difference between the two groups. The mean scores of the pre-test for the control group and the intervention group were 6.18 and 6.13 respectively (P=0.9). In the post-test, the mean score of the students in the intervention group was considerably higher: 9.25 vs. 12 (P=0.002). The students in the intervention group found the study guides useful. The study guides were potentially effective in motivating self-learning in this group of medical students and had a remarkable effect on their final score.
Karyotaki, E; Kleiboer, A; Smit, F; Turner, D T; Pastor, A M; Andersson, G; Berger, T; Botella, C; Breton, J M; Carlbring, P; Christensen, H; de Graaf, E; Griffiths, K; Donker, T; Farrer, L; Huibers, M J H; Lenndin, J; Mackinnon, A; Meyer, B; Moritz, S; Riper, H; Spek, V; Vernmark, K; Cuijpers, P
2015-10-01
It is well known that web-based interventions can be effective treatments for depression. However, dropout rates in web-based interventions are typically high, especially in self-guided web-based interventions. Rigorous empirical evidence regarding factors influencing dropout in self-guided web-based interventions is lacking due to small study sample sizes. In this paper we examined predictors of dropout in an individual patient data meta-analysis to gain a better understanding of who may benefit from these interventions. A comprehensive literature search for all randomized controlled trials (RCTs) of psychotherapy for adults with depression from 2006 to January 2013 was conducted. Next, we approached authors to collect the primary data of the selected studies. Predictors of dropout, such as socio-demographic, clinical, and intervention characteristics were examined. Data from 2705 participants across ten RCTs of self-guided web-based interventions for depression were analysed. The multivariate analysis indicated that male gender [relative risk (RR) 1.08], lower educational level (primary education, RR 1.26) and co-morbid anxiety symptoms (RR 1.18) significantly increased the risk of dropping out, while for every additional 4 years of age, the risk of dropping out significantly decreased (RR 0.94). Dropout can be predicted by several variables and is not randomly distributed. This knowledge may inform tailoring of online self-help interventions to prevent dropout in identified groups at risk.
Yamamoto, Takuya; Moyama, Shota; Yano, Hideki
2017-03-01
We devised a new system called "Educational Guidance" (E-Guide) for nutritional education based on self-efficacy. The present study aimed to examine the effects of E-Guide use on glycemic control among patients with type 2 diabetes. We carried out an interventional and observational study that included 74 patients with type 2 diabetes. The extent of glycemic control in the 39 patients who received guidance through the E-Guide (E-Guide group) was compared with that of 35 patients who received conventional nutritional guidance (control group). We carried out a 1-year follow-up survey (subanalysis) based on the electronic health records of 18 patients from the E-guide group and 19 patients from the control group. These patients continued treatment at Hikone Municipal Hospital, Hikone, Shiga, Japan. Changes in glycated hemoglobin levels, body mass index and medication dose were examined from time of enrollment to the end of the 1-year intervention, and during the 1-year follow-up. Decreases in glycated hemoglobin levels were more pronounced in the E-Guide group than in the control group during the intervention period (P < 0.05). The levels further decreased during the follow-up period (P < 0.01). In the E-Guide group, body mass index decreased significantly throughout the follow-up period (P < 0.001). Additionally, increased medication doses were significantly less common in the E-Guide group than in the control group (P < 0.01). Intervention based on our "E-Guide" is more useful and powerful than the conventional methods for glycemic control and self-care behavior among patients with type 2 diabetes in Japan. © 2016 The Authors. Journal of Diabetes Investigation published by Asian Association for the Study of Diabetes (AASD) and John Wiley & Sons Australia, Ltd.
Growing: Birth to Three. Piecing It All Together.
ERIC Educational Resources Information Center
Doan-Sampon, Mary Anne; And Others
This guide is one part of a set of materials designed to support an ecological intervention system for families and their special needs children between birth and three. The system is constructed on four premises: (1) intervention is guided by the family; (2) parent-child interactions are the heart of early intervention; (3) family rituals, daily…
Ramírez, I; Pantrigo, J J; Montemayor, A S; López-Pérez, A E; Martín-Fontelles, M I; Brookes, S J H; Abalo, R
2017-08-01
When available, fluoroscopic recordings are a relatively cheap, non-invasive and technically straightforward way to study gastrointestinal motility. Spatiotemporal maps have been used to characterize motility of intestinal preparations in vitro, or in anesthetized animals in vivo. Here, a new automated computer-based method was used to construct spatiotemporal motility maps from fluoroscopic recordings obtained in conscious rats. Conscious, non-fasted, adult, male Wistar rats (n=8) received intragastric administration of barium contrast, and 1-2 hours later, when several loops of the small intestine were well-defined, a 2 minutes-fluoroscopic recording was obtained. Spatiotemporal diameter maps (Dmaps) were automatically calculated from the recordings. Three recordings were also manually analyzed for comparison. Frequency analysis was performed in order to calculate relevant motility parameters. In each conscious rat, a stable recording (17-20 seconds) was analyzed. The Dmaps manually and automatically obtained from the same recording were comparable, but the automated process was faster and provided higher resolution. Two frequencies of motor activity dominated; lower frequency contractions (15.2±0.9 cpm) had an amplitude approximately five times greater than higher frequency events (32.8±0.7 cpm). The automated method developed here needed little investigator input, provided high-resolution results with short computing times, and automatically compensated for breathing and other small movements, allowing recordings to be made without anesthesia. Although slow and/or infrequent events could not be detected in the short recording periods analyzed to date (17-20 seconds), this novel system enhances the analysis of in vivo motility in conscious animals. © 2017 John Wiley & Sons Ltd.
Lever, Teresa E.; Braun, Sabrina M.; Brooks, Ryan T.; Harris, Rebecca A.; Littrell, Loren L.; Neff, Ryan M.; Hinkel, Cameron J.; Allen, Mitchell J.; Ulsas, Mollie A.
2015-01-01
This study adapted human videofluoroscopic swallowing study (VFSS) methods for use with murine disease models for the purpose of facilitating translational dysphagia research. Successful outcomes are dependent upon three critical components: test chambers that permit self-feeding while standing unrestrained in a confined space, recipes that mask the aversive taste/odor of commercially-available oral contrast agents, and a step-by-step test protocol that permits quantification of swallow physiology. Elimination of one or more of these components will have a detrimental impact on the study results. Moreover, the energy level capability of the fluoroscopy system will determine which swallow parameters can be investigated. Most research centers have high energy fluoroscopes designed for use with people and larger animals, which results in exceptionally poor image quality when testing mice and other small rodents. Despite this limitation, we have identified seven VFSS parameters that are consistently quantifiable in mice when using a high energy fluoroscope in combination with the new murine VFSS protocol. We recently obtained a low energy fluoroscopy system with exceptionally high imaging resolution and magnification capabilities that was designed for use with mice and other small rodents. Preliminary work using this new system, in combination with the new murine VFSS protocol, has identified 13 swallow parameters that are consistently quantifiable in mice, which is nearly double the number obtained using conventional (i.e., high energy) fluoroscopes. Identification of additional swallow parameters is expected as we optimize the capabilities of this new system. Results thus far demonstrate the utility of using a low energy fluoroscopy system to detect and quantify subtle changes in swallow physiology that may otherwise be overlooked when using high energy fluoroscopes to investigate murine disease models. PMID:25866882
Kim, Pyeong Hwa; Song, Ho-Young; Park, Jung-Hoon; Zhou, Wei-Zhong; Na, Han Kyu; Cho, Young Chul; Jun, Eun Jung; Kim, Jun Ki; Kim, Guk Bae
2017-03-01
To evaluate clinical outcomes of fluoroscopic removal of retrievable self-expandable metal stents (SEMSs) for malignant oesophageal strictures, to compare clinical outcomes of three different removal techniques, and to identify predictive factors of successful removal by the standard technique (primary technical success). A total of 137 stents were removed from 128 patients with malignant oesophageal strictures. Primary overall technical success and removal-related complications were evaluated. Logistic regression models were constructed to identify predictive factors of primary technical success. Primary technical success rate was 78.8 % (108/137). Complications occurred in six (4.4 %) cases. Stent location in the upper oesophagus (P=0.004), stricture length over 8 cm (P=0.030), and proximal granulation tissue (P<0.001) were negative predictive factors of primary technical success. If granulation tissue was present at the proximal end, eversion technique was more frequently required (P=0.002). Fluoroscopic removal of retrievable SEMSs for malignant oesophageal strictures using three different removal techniques appeared to be safe and easy. The standard technique is safe and effective in the majority of patients. The presence of proximal granulation tissue, stent location in the upper oesophagus, and stricture length over 8 cm were negative predictive factors for primary technical success by standard extraction and may require a modified removal technique. • Fluoroscopic retrievable SEMS removal is safe and effective. • Standard removal technique by traction is effective in the majority of patients. • Three negative predictive factors of primary technical success were identified. • Caution should be exercised during the removal in those situations. • Eversion technique is effective in cases of proximal granulation tissue.
Marker Configuration Model-Based Roentgen Fluoroscopic Analysis.
Garling, Eric H; Kaptein, Bart L; Geleijns, Koos; Nelissen, Rob G H H; Valstar, Edward R
2005-04-01
It remains unknown if and how the polyethylene bearing in mobile bearing knees moves during dynamic activities with respect to the tibial base plate. Marker Configuration Model-Based Roentgen Fluoroscopic Analysis (MCM-based RFA) uses a marker configuration model of inserted tantalum markers in order to accurately estimate the pose of an implant or bone using single plane Roentgen images or fluoroscopic images. The goal of this study is to assess the accuracy of (MCM-Based RFA) in a standard fluoroscopic set-up using phantom experiments and to determine the error propagation with computer simulations. The experimental set-up of the phantom study was calibrated using a calibration box equipped with 600 tantalum markers, which corrected for image distortion and determined the focus position. In the computer simulation study the influence of image distortion, MC-model accuracy, focus position, the relative distance between MC-models and MC-model configuration on the accuracy of MCM-Based RFA were assessed. The phantom study established that the in-plane accuracy of MCM-Based RFA is 0.1 mm and the out-of-plane accuracy is 0.9 mm. The rotational accuracy is 0.1 degrees. A ninth-order polynomial model was used to correct for image distortion. Marker-Based RFA was estimated to have, in a worst case scenario, an in vivo translational accuracy of 0.14 mm (x-axis), 0.17 mm (y-axis), 1.9 mm (z-axis), respectively, and a rotational accuracy of 0.3 degrees. When using fluoroscopy to study kinematics, image distortion and the accuracy of models are important factors, which influence the accuracy of the measurements. MCM-Based RFA has the potential to be an accurate, clinically useful tool for studying kinematics after total joint replacement using standard equipment.
Stanley, Jeremy C; Robinson, Kerian G; Devitt, Brian M; Richmond, Anneka K; Webster, Kate E; Whitehead, Timothy S; Feller, Julian A
2016-03-01
There are numerous methods available to assist surgeons in the accurate correction of varus alignment during medial opening wedge high tibial osteotomy (MOWHTO). Preoperative planning performed with radiographs or more recently intraoperative computer navigation software has been used. The aim of the study was to compare the accuracy of computer navigated versus non-navigated techniques to correct varus alignment of the knee. The preoperative and postoperative radiographs of 117 knees that underwent MOWHTO were investigated to assess radiographic limb alignment 12-months postoperatively. The desired correction was defined as a weight bearing line (Mikulicz point {MP}) 58% of the width of the tibial plateau from the medial tibial margin. Sixty-five knees were corrected using a conventional technique and 52 knees were corrected using computer navigation. The mean MP percentage was 59% in the navigated group, compared with 56% in the fluoroscopic group (p=0.183). 51.9% of the navigation knees were corrected to within five percent of the desired correction, in contrast to 38.5% of the fluoroscopically corrected knees (p=0.15). 71.2% of the navigated knees were corrected to within 10% of the desired correction, compared with 63.1% of the fluoroscopically corrected knees (p=0.36). Large preoperative deformities were more accurately corrected with navigation assistance (57% vs 49%, p=0.049). No statistically significant difference was found in the radiographic correction of varus alignment twelve months postoperatively between navigated and fluoroscopic techniques of MOWHTO. However, a subgroup analysis demonstrated that larger preoperative varus deformities may be more accurately corrected using computer navigation. Copyright © 2016 Elsevier B.V. All rights reserved.
Wang, Junqiang; Wang, Yu; Zhu, Gang; Chen, Xiangqian; Zhao, Xiangrui; Qiao, Huiting; Fan, Yubo
2018-06-01
Spatial positioning accuracy is a key issue in a computer-assisted orthopaedic surgery (CAOS) system. Since intraoperative fluoroscopic images are one of the most important input data to the CAOS system, the quality of these images should have a significant influence on the accuracy of the CAOS system. But the regularities and mechanism of the influence of the quality of intraoperative images on the accuracy of a CAOS system have yet to be studied. Two typical spatial positioning methods - a C-arm calibration-based method and a bi-planar positioning method - are used to study the influence of different image quality parameters, such as resolution, distortion, contrast and signal-to-noise ratio, on positioning accuracy. The error propagation rules of image error in different spatial positioning methods are analyzed by the Monte Carlo method. Correlation analysis showed that resolution and distortion had a significant influence on spatial positioning accuracy. In addition the C-arm calibration-based method was more sensitive to image distortion, while the bi-planar positioning method was more susceptible to image resolution. The image contrast and signal-to-noise ratio have no significant influence on the spatial positioning accuracy. The result of Monte Carlo analysis proved that generally the bi-planar positioning method was more sensitive to image quality than the C-arm calibration-based method. The quality of intraoperative fluoroscopic images is a key issue in the spatial positioning accuracy of a CAOS system. Although the 2 typical positioning methods have very similar mathematical principles, they showed different sensitivities to different image quality parameters. The result of this research may help to create a realistic standard for intraoperative fluoroscopic images for CAOS systems. Copyright © 2018 John Wiley & Sons, Ltd.
Accuracy and Consistency of Respiratory Gating in Abdominal Cancer Patients
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ge, Jiajia; Santanam, Lakshmi; Yang, Deshan
2013-03-01
Purpose: To evaluate respiratory gating accuracy and intrafractional consistency for abdominal cancer patients treated with respiratory gated treatment on a regular linear accelerator system. Methods and Materials: Twelve abdominal patients implanted with fiducials were treated with amplitude-based respiratory-gated radiation therapy. On the basis of daily orthogonal fluoroscopy, the operator readjusted the couch position and gating window such that the fiducial was within a setup margin (fiducial-planning target volume [f-PTV]) when RPM indicated “beam-ON.” Fifty-five pre- and post-treatment fluoroscopic movie pairs with synchronized respiratory gating signal were recorded. Fiducial motion traces were extracted from the fluoroscopic movies using a template matchingmore » algorithm and correlated with f-PTV by registering the digitally reconstructed radiographs with the fluoroscopic movies. Treatment was determined to be “accurate” if 50% of the fiducial area stayed within f-PTV while beam-ON. For movie pairs that lost gating accuracy, a MATLAB program was used to assess whether the gating window was optimized, the external-internal correlation (EIC) changed, or the patient moved between movies. A series of safety margins from 0.5 mm to 3 mm was added to f-PTV for reassessing gating accuracy. Results: A decrease in gating accuracy was observed in 44% of movie pairs from daily fluoroscopic movies of 12 abdominal patients. Three main causes for inaccurate gating were identified as change of global EIC over time (∼43%), suboptimal gating setup (∼37%), and imperfect EIC within movie (∼13%). Conclusions: Inconsistent respiratory gating accuracy may occur within 1 treatment session even with a daily adjusted gating window. To improve or maintain gating accuracy during treatment, we suggest using at least a 2.5-mm safety margin to account for gating and setup uncertainties.« less
Image-guided techniques in renal and hepatic interventions.
Najmaei, Nima; Mostafavi, Kamal; Shahbazi, Sahar; Azizian, Mahdi
2013-12-01
Development of new imaging technologies and advances in computing power have enabled the physicians to perform medical interventions on the basis of high-quality 3D and/or 4D visualization of the patient's organs. Preoperative imaging has been used for planning the surgery, whereas intraoperative imaging has been widely employed to provide visual feedback to a clinician when he or she is performing the procedure. In the past decade, such systems demonstrated great potential in image-guided minimally invasive procedures on different organs, such as brain, heart, liver and kidneys. This article focuses on image-guided interventions and surgery in renal and hepatic surgeries. A comprehensive search of existing electronic databases was completed for the period of 2000-2011. Each contribution was assessed by the authors for relevance and inclusion. The contributions were categorized on the basis of the type of operation/intervention, imaging modality and specific techniques such as image fusion and augmented reality, and organ motion tracking. As a result, detailed classification and comparative study of various contributions in image-guided renal and hepatic interventions are provided. In addition, the potential future directions have been sketched. With a detailed review of the literature, potential future trends in development of image-guided abdominal interventions are identified, namely, growing use of image fusion and augmented reality, computer-assisted and/or robot-assisted interventions, development of more accurate registration and navigation techniques, and growing applications of intraoperative magnetic resonance imaging. Copyright © 2012 John Wiley & Sons, Ltd.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cazzato, Roberto Luigi, E-mail: r.cazzato@unicampus.it; Buy, Xavier, E-mail: x.buy@bordeaux.unicancer.fr; Alberti, Nicolas, E-mail: nicoalbertibdx@gmail.com
2015-02-15
PurposeThe aim of the present study was to investigate the technical feasibility of flat-panel cone-beam CT (CBCT)-guided radiofrequency ablation (RFA) of very small (<1.5 cm) liver tumors.Materials and MethodsPatients included were candidates for hepatic percutaneous RFA as they had single biopsy-proven hepatic tumors sized ≤1.5 cm and poorly defined on ultrasonography. Following apnea induction, unenhanced CBCT scans were acquired and used to deploy the RF electrode with the aid of a virtual navigation system. If the tumor was not clearly identified on the unenhanced CBCT scan, a right retrograde arterial femoral access was established to carry out hepatic angiography and localize themore » tumor. Patients’ lesions and procedural variables were recorded and analyzed.ResultsThree patients (2 male and 1 female), aged 68, 76, and 87 years were included; 3 lesions (2 hepato-cellular carcinoma and 1 metastasis from colorectal cancer) were treated. One patient required hepatic angiography. Cycles of apnea used to acquire CBCT images and to deploy the electrode lasted <120 s. Mean fluoroscopic time needed to deploy the electrode was 36.6 ± 5.7 min. Mean overall procedural time was 66.0 ± 22.9 min. No peri- or post-procedural complications were noted. No cases of incomplete ablation were noted at 1-month follow-up.ConclusionPercutaneous CBCT-guided liver RFA with or without arterial hepatic angiography is technically feasible.« less
Leeman, Jennifer; Moore, Alexis; Teal, Randall; Barrett, Nadine; Leighton, Ashely; Steckler, Allan
2013-07-01
Many women do not get mammography screenings at the intervals recommended for early detection and treatment of breast cancer. The Guide to Community Preventive Services (Community Guide) recommends a range of evidence-based strategies to improve mammography rates. However, nurses and others working in community-based settings make only limited use of these strategies. We report on a dissemination intervention that partnered the University of North Carolina with the Susan G. Komen Triangle Affiliate to disseminate Community Guide breast cancer screening strategies to community organizations. The intervention was guided by social marketing and diffusion of innovation theory and was designed to provide evidence and support via Komen's existing relationships with grantee organizations. The present study reports the findings from a formative evaluation of the intervention, which included a content analysis of 46 grant applications pre- and post intervention and focus groups with 20 grant recipients. © 2013 Wiley Periodicals, Inc.
Ainscough, Kate M; Lindsay, Karen L; O'Sullivan, Elizabeth J; Gibney, Eileen R; McAuliffe, Fionnuala M
2017-10-01
Antenatal healthy lifestyle interventions are frequently implemented in overweight and obese pregnancy, yet there is inconsistent reporting of the behaviour-change methods and behavioural outcomes. This limits our understanding of how and why such interventions were successful or not. The current paper discusses the application of behaviour-change theories and techniques within complex lifestyle interventions in overweight and obese pregnancy. The authors propose a decision tree to help guide researchers through intervention design, implementation and evaluation. The implications for adopting behaviour-change theories and techniques, and using appropriate guidance when constructing and evaluating interventions in research and clinical practice are also discussed. To enhance the evidence base for successful behaviour-change interventions during pregnancy, adoption of behaviour-change theories and techniques, and use of published guidelines when designing lifestyle interventions are necessary. The proposed decision tree may be a useful guide for researchers working to develop effective behaviour-change interventions in clinical settings. This guide directs researchers towards key literature sources that will be important in each stage of study development.
Value of Image Fusion in Coronary Angiography for the Detection of Coronary Artery Bypass Grafts.
Plessis, Julien; Warin Fresse, Karine; Cahouch, Zachary; Manigold, Thibaut; Letocart, Vincent; Le Gloan, Laurianne; Guyomarch, Béatrice; Guerin, Patrice
2016-06-10
Coronary angiography is more complex in patients with coronary artery bypass grafts (CABG). Image fusion is a new technology that allows the overlay of a computed tomography (CT) three-dimension (3D) model with fluoroscopic images in real time. This single-center prospective study included 66 previous CABG patients undergoing coronary and bypass graft angiography. Image fusion coronary angiographies (fusion group, 20 patients) were compared to conventional coronary angiographies (control group, 46 patients). The fusion group included patients for whom a previous chest CT scan with contrast was available. For patients in this group, aorta and CABG were reconstructed in 3D from CT acquisitions and merged in real time with fluoroscopic images. The following parameters were compared: time needed to localize the CABG; procedure duration; air kerma (AK); dose area product (DAP); and volume of contrast media injected. Results are expressed as median. There were no significant differences between the 2 groups in patient demographics and procedure characteristics (access site, number of bypass to be found, and interventional cardiologist's experience). The time to localize CABG was significantly shorter in the fusion group (7.3 versus 12.4 minutes; P=0.002), as well as the procedure duration (20.6 versus 25.6 minutes; P=0.002), AK (610 versus 814 mGy; P=0.02), DAP (4390 versus 5922.5 cGy·cm(2); P=0.02), and volume of iodinated contrast media (85 versus 116 cc; P=0.002). 3D image fusion improves the CABG detection in coronary angiography and reduces the time necessary to localize CABG, total procedure time duration, radiation exposure, and volume of contrast media. © 2016 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.
Goltz, J P; Noack, C; Petritsch, B; Kirchner, J; Hahn, D; Kickuth, R
2012-01-01
Objectives To evaluate the technical success, clinical outcome and safety of percutaneously placed totally implantable venous power ports (TIVPPs) approved for high-pressure injections, and to analyse their value for arterial phase CT scans. Methods Retrospectively, we identified 204 patients who underwent TIVPP implantation in the forearm (n=152) or chest (n=52) between November 2009 and May 2011. Implantation via an upper arm (forearm port, FP) or subclavian vein (chest port, CP) was performed under sonographic and fluoroscopic guidance. Complications were evaluated following the standards of the Society of Interventional Radiology. Power injections via TIVPPs were analysed, focusing on adequate functioning and catheter's tip location after injection. Feasibility of automatic bolus triggering, peak injection pressure and arterial phase aortic enhancement were evaluated and compared with 50 patients who had had power injections via classic peripheral cannulas. Results Technical success was 100%. Procedure-related complications were not observed. Catheter-related thrombosis was diagnosed in 15 of 152 FPs (9.9%, 0.02/100 catheter days) and in 1 of 52 CPs (1.9%, 0.002/100 catheter days) (p<0.05). Infectious complications were diagnosed in 9 of 152 FPs (5.9%, 0.014/100 catheter days) and in 2 of 52 CPs (3.8%, 0.003/100 catheter days) (p>0.05). Arterial bolus triggering succeeded in all attempts; the mean injection pressure was 213.8 psi. Aortic enhancement did not significantly differ between injections via cannulas and TIVPPs (p>0.05). Conclusions TIVPPs can be implanted with high technical success rates, and are associated with low rates of complications if implanted with sonographic and fluoroscopic guidance. Power injections via TIVPPs are safe and result in satisfying arterial contrast. Conventional ports should be replaced by TIVPPs. PMID:22674705
Intra-operative measurement of applied forces during anterior scoliosis correction.
Fairhurst, H; Little, J P; Adam, C J
2016-12-01
Spinal instrumentation and fusion for the treatment of scoliosis is primarily a mechanical intervention to correct the deformity and halt further progression. While implant-related complications remain a concern, little is known about the magnitudes of the forces applied to the spine during surgery, which may affect post-surgical outcomes. In this study, the compressive forces applied to each spinal segment during anterior instrumentation were measured in a series of patients with Adolescent Idiopathic Scoliosis. A force transducer was designed and retrofit to a routinely used surgical tool, and compressive forces applied to each segment during surgery were measured for 15 scoliosis patients. Cobb angle correction achieved by each force was measured on intra-operative fluoroscope images. Relative changes in orientation of the screw within the vertebra were also measured to detect intra-operative screw plough. Intra-operative forces were measured for a total of 95 spinal segments. The mean applied compressive force was 540N (SD 230N, range 88N-1019N). There was a clear trend for higher forces to be applied at segments toward the apex of the scoliosis. Fluoroscopic evidence of screw plough was detected at 10 segments (10.5%). The magnitude of forces applied during anterior scoliosis correction vary over a broad range. These forces do reach magnitudes capable of causing intra-operative vertebral body screw plough. Surgeons should be aware there is a risk for tissue overload during correction, however the clinical implications of intra-operative screw plough remain unclear. The dataset presented here is valuable for providing realistic input parameters for in silico surgical simulations. Copyright © 2016 Elsevier Ltd. All rights reserved.
Olcay, Ayhan; Guler, Ekrem; Karaca, Ibrahim Oguz; Omaygenc, Mehmet Onur; Kizilirmak, Filiz; Olgun, Erkam; Yenipinar, Esra; Cakmak, Huseyin Altug; Duman, Dursun
2015-04-01
Use of last fluoro hold (LFH) mode in fluoroscopy, which enables the last live image to be saved and displayed, could reduce radiation during percutaneous coronary intervention when compared with cine mode. No previous study compared coronary angiography radiation doses and image quality between LFH and conventional cine mode techniques. We compared cumulative dose-area product (DAP), cumulative air kerma, fluoroscopy time, contrast use, interobserver variability of visual assessment between LFH angiography, and conventional cine angiography techniques. Forty-six patients were prospectively enrolled into the LFH group and 82 patients into the cine angiography group according to operator decision. Mean cumulative DAP was higher in the cine group vs the LFH group (50058.98 ± 53542.71 mGy•cm² vs 11349.2 ± 8796.46 mGy•cm²; P<.001). Mean fluoroscopy times were higher in the cine group vs the LFH group (3.87 ± 5.08 minutes vs 1.66 ± 1.51 minutes; P<.01). Mean contrast use was higher in the cine group vs the LFH group (112.07 ± 43.79 cc vs 88.15 ± 23.84 cc; P<.001). Mean value of Crombach's alpha was not statistically different between visual estimates of three operators between cine and LFH angiography groups (0.66680 ± 0.19309 vs 0.54193 ± 0.31046; P=.20). Radiation doses, contrast use, and fluoroscopy times are lower in fluoroscopic LFH angiography vs cine angiography. Interclass variability of visual stenosis estimation between three operators was not different between cine and LFH groups. Fluoroscopic LFH images conventionally have inferior diagnostic quality when compared with cine coronary angiography, but with new angiographic systems with improved LFH image quality, these images may be adequate for diagnostic coronary angiography.
Briss, P A; Zaza, S; Pappaioanou, M; Fielding, J; Wright-De Agüero, L; Truman, B I; Hopkins, D P; Mullen, P D; Thompson, R S; Woolf, S H; Carande-Kulis, V G; Anderson, L; Hinman, A R; McQueen, D V; Teutsch, S M; Harris, J R
2000-01-01
Systematic reviews and evidence-based recommendations are increasingly important for decision making in health and medicine. Over the past 20 years, information on the science of synthesizing research results has exploded. However, some approaches to systematic reviews of the effectiveness of clinical preventive services and medical care may be less appropriate for evaluating population-based interventions. Furthermore, methods for linking evidence to recommendations are less well developed than methods for synthesizing evidence. The Guide to Community Preventive Services: Systematic Reviews and Evidence-Based Recommendations (the Guide) will evaluate and make recommendations on population-based and public health interventions. This paper provides an overview of the Guide's process to systematically review evidence and translate that evidence into recommendations. The Guide reviews evidence on effectiveness, the applicability of effectiveness data, (i.e., the extent to which available effectiveness data is thought to apply to additional populations and settings), the intervention's other effects (i.e., important side effects), economic impact, and barriers to implementation of interventions. The steps for obtaining and evaluating evidence into recommendations involve: (1) forming multidisciplinary chapter development teams, (2) developing a conceptual approach to organizing, grouping, selecting and evaluating the interventions in each chapter; (3) selecting interventions to be evaluated; (4) searching for and retrieving evidence; (5) assessing the quality of and summarizing the body of evidence of effectiveness; (6) translating the body of evidence of effectiveness into recommendations; (7) considering information on evidence other than effectiveness; and (8) identifying and summarizing research gaps. Systematic reviews of and evidence-based recommendations for population-health interventions are challenging and methods will continue to evolve. However, using an evidence-based approach to identify and recommend effective interventions directed at specific public health goals may reduce errors in how information is collected and interpreted, identify important gaps in current knowledge thus guiding further research, and enhance the Guide users' ability to assess whether recommendations are valid and prudent from their own perspectives. Over time, all of these advantages could help to increase agreement regarding appropriate community health strategies and help to increase their implementation.
Vad, Vijay B; Solomon, Jennifer; Adin, David R
2005-06-01
To study the efficacy of subacromial shoulder irrigation in the treatment of calcific rotator cuff tendinosis. Consecutive case series. Musculoskeletal rehabilitation clinic. Twenty-eight tennis players (16 women, 12 men; mean age, 44.3y) with calcific rotator cuff tendinosis, who failed conservative measures. Subjects underwent fluoroscopically guided subacromial shoulder irrigation (50-75 mL of normal saline in 10 mL aliquots) followed by a corticosteroid injection (5 mL solution of 1 mL triamcinolone [40 mg/mL] and 4 mL of 0.5% bupivacaine). After the procedure, all patients completed the same exercise regimen. LInsalata Shoulder Rating Questionnaire (LSRQ) score, visual numeric pain score, and patient satisfaction. At 1-year follow-up, 85.7% reported a successful outcome with significant improvements in the LSQR and numeric pain scores. Our minimally invasive approach was safe, well tolerated, and effective, which should make it useful in providing relief for patients with rotator cuff tendinosis.
Epidural steroid injections in the management of a patient with spinal stenosis and urinary urgency.
Mitra, Raj; Huang, Lawrence; Payne, Christopher
2009-02-01
A 79-year-old woman with a history of chronic back pain and urinary urgency presented to a spine center for treatment and evaluation for axial low back pain. The patient described the back pain as severe with intermittent radiation into the right leg; her pain intensity was 7 out of 10 on a visual analog scale. She described her sense of urgency as severe, and could delay urination for 10 min or less. She described her bladder control as 6 out of 10 on the urgency perception score (with 0 being perfect control). Physical examination, including manual muscle testing, test for sensation to fine touch, reflex assessment and assessment of gait pattern, and MRI of the lumbar spine. Overactive bladder associated with severe central-canal stenosis at L4-5, in the setting of anterolisthesis. Fluoroscopically guided caudal epidural steroid injection; 60 mg of triamcinolone, 3 ml of 1% lidocaine hydrochloride and 3 ml of normal saline, injected in increments.
Burnham, Robert
2010-06-01
Describe the clinical presentation, diagnostic evaluation, and successful treatment of a case of symptomatic unilateral lumbosacral junction pseudarticulation using a novel radiofrequency nerve ablation technique. A 56-year-old female patient who had suffered with low back and right upper buttock pain for 16 years experienced incomplete relief with L4/5 facet joint radiofrequency ablation. She was found to have an elongated right L5 transverse process that articulated with the sacral ala (Bertolotti's syndrome). Fluoroscopically guided local anesthetic/corticosteroid injection into the pseudarthrosis eliminated her residual right buttock pain for the duration of the local anesthetic only. Complete pain relief was achieved by injecting local anesthetic circumferentially around the posterior pseudarthrosis articular margin. Accordingly, bipolar radiofrequency strip thermal lesions were created at the same locations. Complete pain relief and full restoration of function was achieved for 16 months postprocedure. This case report describes a novel radiofrequency technique for treating symptomatic lumbosacral junction pseudarticulation that warrants further evaluation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ko, Gi-Young; Song, Ho-Young, E-mail: hysong@amc.seoul.kr; Hong, Heuk-Jin
2003-04-15
Purpose: To assess the efficacy of balloon dilation combined with chemotherapy and/or radiation therapy for palliation of dysphagia due to malignant esophagogastric junction strictures. Methods: Fluoroscopically guided balloon dilation was attempted in 20 patients. The causes of strictures were gastric adenocarcinoma (n = 10) and esophageal squamous cell carcinoma (n = 10). Scheduled chemotherapy and/or radiation therapy followed balloon dilation in all patients. Results: There were no technical failures or major complications. After balloon dilation, 15 (75%) patients showed improvement of dysphagia. No patient complained of reflux esophagitis during the follow-up period. Among the 15 patients, seven needed no furthermore » treatment for palliation of dysphagia until their deaths. The remaining eight patients underwent repeat balloon dilation(n = 4) or stent placement (n = 4)3-43 weeks (mean 15 weeks) after the initial balloon dilation because of recurrent dysphagia. Conclusion: Balloon dilation combined with chemotherapy and/or radiation therapy seems to be an easy and reasonably effective palliative treatment for malignant esophagogastric strictures.« less
Kim, Ok Sun; Jeong, Seung Min; Ro, Ji Young; Kim, Duck Kyoung; Koh, Young Cho; Ko, Young Sin; Lim, So Dug; Kim, Hae Kyoung
2010-01-01
Occipital neuralgia is a form of headache that involves the posterior occiput in the greater or lesser occipital nerve distribution. Pain can be severe and persistent with conservative treatment. We present a case of intractable occipital neuralgia that conventional therapeutic modalities failed to ameliorate. We speculate that, in this case, the cause of headache could be the greater occipital nerve entrapment by the obliquus capitis inferior muscle. After steroid and local anesthetic injection into obliquus capitis inferior muscles under fluoroscopic and sonographic guidance, the visual analogue scale was decreased from 9-10/10 to 1-2/10 for 2-3 weeks. The patient eventually got both greater occipital neurectomy and partial resection of obliquus capitis inferior muscles due to the short term effect of the injection. The successful steroid and local anesthetic injection for this occipital neuralgia shows that the refractory headache was caused by entrapment of greater occipital nerves by obliquus capitis inferior muscles. PMID:20552081
ERIC Educational Resources Information Center
Loizou, Eleni
2017-01-01
Drawing on the work of Vygotsky on scaffolding play and research on teacher intervention and mature forms of play, we have developed a teacher guide about play which frames children's role and scenario development and provides a teacher play intervention schema. The research question explored in this study is "How does a teacher guide,…
A cluster randomized theory-guided oral hygiene trial in adolescents-A latent growth model.
Aleksejūnienė, J; Brukienė, V
2018-05-01
(i) To test whether theory-guided interventions are more effective than conventional dental instruction (CDI) for changing oral hygiene in adolescents and (ii) to examine whether such interventions equally benefit both genders and different socio-economic (SES) groups. A total of 244 adolescents were recruited from three schools, and cluster randomization allocated adolescents to one of the three types of interventions: two were theory-based interventions (Precaution Adoption Process Model or Authoritative Parenting Model) and CDI served as an active control. Oral hygiene levels % (OH) were assessed at baseline, after 3 months and after 12 months. A complete data set was available for 166 adolescents (the total follow-up rate: 69%). There were no significant differences in baseline OH between those who participated throughout the study and those who dropped out. Bivariate and multivariate analyses showed that theory-guided interventions produced significant improvements in oral hygiene and that there were no significant gender or socio-economic differences. Theory-guided interventions produced more positive changes in OH than CDI, and these changes did not differ between gender and SES groups. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Daponte, Antonio; Bernal, Mariola; Bolívar, Julia; Mateo, Inmaculada; Salmi, Louis-Rachid; Barsanti, Sara; Berghmans, Luc; Piznal, Ewelina; Bourgueil, Yann; Marquez, Soledad; González, Ingrid; Carriazo, Ana; Maros-Szabo, Zsuzsanna; Ménival, Solange
2014-12-01
The current social and political context is generating socio-economic inequalities between and within countries, causing and widening health inequalities. The development and implementation of interventions in primary health care (PHC) settings seem unavoidable. Attempts have been made to draw up adequate criteria to guide and evaluate interventions but none for the specific case of PHC. This methodological article aims to contribute to this field by developing and testing a set of criteria for guiding and evaluating real-life interventions to reduce health inequalities in PHC settings in European regions. A literature review, nominal group technique, survey and evaluation template were used to design and test a set of criteria. The questionnaire was answered by professionals in charge of 46 interventions carried out in 12 European countries, and collected detailed information about each intervention. Third-party experts scored the interventions using the set of evaluation criteria proposed. Nine criteria to guide and evaluate interventions were proposed: relevance, appropriateness, applicability, innovation, quality assurance, adequacy of resources, effectiveness in the process, effectiveness in results and mainstreaming. A working definition was drawn up for each one. These criteria were then used to evaluate the interventions identified. The set of criteria drawn up to guide the design, implementation and evaluation of interventions to reduce health inequalities in PHC will be a useful instrument to be applied to interventions under development for culturally, politically and socio-economically diverse PHC contexts throughout Europe. © The Author 2014. Published by Oxford University Press on behalf of the European Public Health Association. All rights reserved.
Radiation exposure of the anesthesiologist in the neurointerventional suite.
Anastasian, Zirka H; Strozyk, Dorothea; Meyers, Philip M; Wang, Shuang; Berman, Mitchell F
2011-03-01
Scatter radiation during interventional radiology procedures can produce cataracts in participating medical personnel. Standard safety equipment for the radiologist includes eye protection. The typical configuration of fluoroscopy equipment directs radiation scatter away from the radiologist and toward the anesthesiologist. This study analyzed facial radiation exposure of the anesthesiologist during interventional neuroradiology procedures. Radiation exposure to the forehead of the anesthesiologist and radiologist was measured during 31 adult neuroradiologic procedures involving the head or neck. Variables hypothesized to affect anesthesiologist exposure were recorded for each procedure. These included total radiation emitted by fluoroscopic equipment, radiologist exposure, number of pharmacologic interventions performed by the anesthesiologist, and other variables. Radiation exposure to the anesthesiologist's face averaged 6.5 ± 5.4 μSv per interventional procedure. This exposure was more than 6-fold greater (P < 0.0005) than for noninterventional angiographic procedures (1.0 ± 1.0) and averaged more than 3-fold the exposure of the radiologist (ratio, 3.2; 95% CI, 1.8-4.5). Multiple linear regression analysis showed that the exposure of the anesthesiologist was correlated with the number of pharmacologic interventions performed by the anesthesiologist and the total exposure of the radiologist. Current guidelines for occupational radiation exposure to the eye are undergoing review and are likely to be lowered below the current 100-150 mSv/yr limit. Anesthesiologists who spend significant time in neurointerventional radiology suites may have ocular radiation exposure approaching that of a radiologist. To ensure parity with safety standards adopted by radiologists, these anesthesiologists should wear protective eyewear.
Conceptual Model of Research to Reduce Stigma Related to Mental Disorders in Adolescents
Pinto-Foltz, Melissa D.; Logsdon, M. Cynthia
2010-01-01
Purpose: To explicate an initial conceptual model that is amenable to testing and guiding anti-stigma interventions with adolescents. Design/Sources Used: Multidisciplinary research and theoretical articles were reviewed. . Conclusions: The conceptual model may guide anti-stigma interventions, and undergo testing and refinement in the future to reflect scientific advances in stigma reduction among adolescents. Use of a conceptual model enhances empirical evaluation of anti-stigma interventions yielding a casual explanation for the intervention effects and enhances clinical applicability of interventions across settings. PMID:19916813
Biomarker-based risk prediction in the community.
AbouEzzeddine, Omar F; McKie, Paul M; Scott, Christopher G; Rodeheffer, Richard J; Chen, Horng H; Michael Felker, G; Jaffe, Allan S; Burnett, John C; Redfield, Margaret M
2016-11-01
Guided by predictive characteristics of cardiovascular biomarkers, we explored the clinical implications of a simulated biomarker-guided heart failure (HF) and major adverse cardiovascular events (MACE) prevention strategy in the community. In a community cohort (n = 1824), the predictive characteristics for HF and MACE of galectin-3 (Gal-3), ST2, high-sensitivity cardiac troponin I (hscTnI), high-sensitivity C-reactive protein (hsCRP), N-terminal pro-brain natriuretic peptide (NT-proBNP) and B-type natriuretic peptide (BNP) were established. We performed number needed to screen (NNS) and treat (NNT) with the intervention analyses according to biomarker screening strategy and intervention efficacy in persons with at least one cardiovascular risk factor. In the entire cohort, for both HF and MACE, the predictive characteristics of NT-proBNP and hscTnI were superior to other biomarkers; alone, in a multimarker model, and adjusting for clinical risk factors. An NT-proBNP-guided preventative intervention with an intervention effect size (4-year hazard ratio for intervention in biomarker positive cohort) of ≤0.7 would reduce the global burden of HF by ≥20% and MACE by ≥15%. From this simulation, the NNS to prevent one HF event or MACE in 4 years would be ≤100 with a NNT to prevent one HF event of ≤20 and one MACE of ≤10. The predictive characteristics of NT-proBNP and hscTnI for HF or MACE in the community are superior to other biomarkers. Biomarker-guided preventative interventions with reasonable efficacy would compare favourably to established preventative interventions. This data provides a framework for biomarker selection which may inform design of biomarker-guided preventative intervention trials. © 2016 The Authors. European Journal of Heart Failure © 2016 European Society of Cardiology.
Grunfeld, E A; Hunter, M S; Yousaf, O
2017-04-01
Up to 80% of men who receive androgen deprivation therapy report hot flushes and for many these are associated with reduced quality of life. However it is recognised that there are a number of barriers to men's engagement with support to manage symptoms and improve quality of life. This qualitative study was embedded within a larger randomised controlled trial (MANCAN) of a guided self-help cognitive behavioural intervention to manage hot flushes resulting among men receiving androgen deprivation therapy. The study aimed to explore the engagement and experiences with the guided self-help intervention. Twenty men recruited from the treatment arm of the MANCAN trial participated in a semi-structured interview exploring acceptability of the intervention, factors affecting engagement and perceived usefulness of the intervention. Interviews were audio-recorded, transcribed verbatim and analysed using a Framework approach. Over two thirds of respondents (69%) reported reading the intervention booklet in full and over 90% reporting practising the relaxation CD at least once a week. Analysis of the interviews identified three super-ordinate themes and these related to changes in hot flush symptomatology (learned to cope with hot flushes in new ways), the skills that participants had derived from the intervention (promoting relaxation and reducing stressors), and to a broader usefulness of the intervention (broader impact of the intervention and skills). The present study identified positive engagement with a guided self-help intervention and that men applied the skills developed through the intervention to help them undertake general lifestyle changes. Psycho-educational interventions (e.g. cognitive behaviour therapy, relaxation, and positive lifestyle elements) offer the potential to be both effective and well received by male cancer survivors.
Radiation exposure of the radiologist's eye lens during CT-guided interventions.
Heusch, Philipp; Kröpil, Patric; Buchbender, Christian; Aissa, Joel; Lanzman, Rotem S; Heusner, Till A; Ewen, Klaus; Antoch, Gerald; Fürst, Günther
2014-02-01
In the past decade the number of computed tomography (CT)-guided procedures performed by interventional radiologists have increased, leading to a significantly higher radiation exposure of the interventionalist's eye lens. Because of growing concern that there is a stochastic effect for the development of lens opacification, eye lens dose reduction for operators and patients should be of maximal interest. To determine the interventionalist's equivalent eye lens dose during CT-guided interventions and to relate the results to the maximum of the recommended equivalent dose limit. During 89 CT-guided interventions (e.g. biopsies, drainage procedures, etc.) measurements of eye lens' radiation doses were obtained from a dedicated dosimeter system for scattered radiation. The sensor of the personal dosimeter system was clipped onto the side of the lead glasses which was located nearest to the CT gantry. After the procedure, radiation dose (µSv), dose rate (µSv/min) and the total exposure time (s) were recorded. For all 89 interventions, the median total exposure lens dose was 3.3 µSv (range, 0.03-218.9 µSv) for a median exposure time of 26.2 s (range, 1.1-94.0 s). The median dose rate was 13.9 µSv/min (range, 1.1-335.5 µSv/min). Estimating 50-200 CT-guided interventions per year performed by one interventionalist, the median dose of the eye lens of the interventional radiologist does not exceed the maximum of the ICRP-recommended equivalent eye lens dose limit of 20 mSv per year.
Grönemeyer, Dietrich H W; Schirp, Sven; Gevargez, Athour
2002-01-01
Metastases to the spine are a challenging problem. Percutaneous, image-guided tumor ablation with a thermal energy source, such as radiofrequency, has received increasing attention as a promising technique for the treatment of focal malignant disease. We used radiofrequency ablation for patients with unresectable, osteolytic spine metastases under computed tomographic and fluoroscopic guidance. The purpose of this study was to determine the feasibility, effectiveness, and safety of radiofrequency ablation as a palliative procedure to reduce pain and back pain-related disability in patients with vertebral and paravertebral spine tumors who were not able to benefit from radiotherapy, chemotherapy, or surgery. Between November 1999 and January 2001, 10 patients with unresectable spine metastases were treated with radiofrequency ablation. For the ablation we used a 50-W radiofrequency generator that is connected to an expandable electrode catheter (RITA Medical System Inc., Mountain View, CA). The mean patient age was 64.4 years. Metastases were ablated in the thoracic spine, the lumbar spine, and/or the sacral bone. Tumor diameter ranged from 1.5 to 9 cm. Combined computed tomographic and fluoroscopic guidance was used to guide the procedure. Operations were carried out without heavy sedation with the patient under local anesthesia only. The thermal lesion was produced by applying temperatures of 50 degrees to 120 degrees C for 8-12 minutes. Vertebroplasty was performed in four patients by use of 3 to 5.5 mL of polymethyl methacrylate. Therapy outcome was documented by magnet resonance imaging. Before the therapy and on follow-up of an average of 5.8 months, pain was assessed with the help of the Visual Analogue Scale. Back pain-related disability was measured with the Hannover Functional Ability Questionnaire. Neurologic and health status were documented on the Frankel score and the Karnofsky index. At follow-up, 9 of 10 patients reported reduced pain (Visual Analogue Scale). In patients who experienced pain relief, there was an average relative pain reduction of 74.4%. Back pain-related disability was reduced by an average of 27%. Neurologic function was preserved in nine patients and improved in one. General health was stabilized in six patients, slightly increased (by 10%-20%) in two patients, significantly enhanced (by 50%) in one patient, and slightly reduced in one patient. No complications were reported. In the treated region, magnetic resonance imaging showed no further tumor growth after the therapy. Radiofrequency ablation was successfully performed in all 10 patients. Needles were placed accurately under image guidance, and a controlled lesion was created. Pain- and back pain-related disability was clearly reduced, and neurologic function was preserved or stabilized. When confirmed by further investigation, this therapy may be a new option for patients with unresectable spine tumors that do not respond to radiotherapy and chemotherapy.
Jiang, Minghuan; You, Joyce Hs
2016-05-01
This study aimed to compare the clinical and economic outcomes of pharmacogenetic-guided (PG-guided) and platelet reactivity testing-guided antiplatelet therapy for patients with acute coronary syndrome undergoing percutaneous coronary intervention. A decision-analytic model was simulated including four antiplatelet strategies: universal clopidogrel 75 mg daily, universal alternative P2Y12 inhibitor (prasugrel or ticagrelor), PG-guided therapy, and platelet reactivity testing-guided therapy. PG-guided therapy was the preferred option with lowest cost (US$75,208) and highest quality-adjusted life years gained (7.6249 quality-adjusted life years). The base-case results were robust in sensitivity analysis. PG-guided antiplatelet therapy showed the highest probability to be preferred antiplatelet strategy for acute coronary syndrome patients with percutaneous coronary intervention.
Simulation of minimally invasive vascular interventions for training purposes.
Alderliesten, Tanja; Konings, Maurits K; Niessen, Wiro J
2004-01-01
To master the skills required to perform minimally invasive vascular interventions, proper training is essential. A computer simulation environment has been developed to provide such training. The simulation is based on an algorithm specifically developed to simulate the motion of a guide wire--the main instrument used during these interventions--in the human vasculature. In this paper, the design and model of the computer simulation environment is described and first results obtained with phantom and patient data are presented. To simulate minimally invasive vascular interventions, a discrete representation of a guide wire is used which allows modeling of guide wires with different physical properties. An algorithm for simulating the propagation of a guide wire within a vascular system, on the basis of the principle of minimization of energy, has been developed. Both longitudinal translation and rotation are incorporated as possibilities for manipulating the guide wire. The simulation is based on quasi-static mechanics. Two types of energy are introduced: internal energy related to the bending of the guide wire, and external energy resulting from the elastic deformation of the vessel wall. A series of experiments were performed on phantom and patient data. Simulation results are qualitatively compared with 3D rotational angiography data. The results indicate plausible behavior of the simulation.
ERIC Educational Resources Information Center
Henn-Reinke, Kathryn
2004-01-01
As a result of recent federal legislation, school districts are being required to have all students reading at grade level by the year 2012. Such an exceedingly lofty goal cannot be achieved without powerful intervention programs. Here is a guide for districts and schools that outlines an intervention program for students in grades 1-3 who…
ERIC Educational Resources Information Center
Emetu, Roberta E.; Marshall, Alexandra; Sanders, Stephanie A.; Yarber, William L.; Milhausen, Robin R.; Crosby, Richard A.; Graham, Cynthia A.
2014-01-01
Objective: This pilot study tested the efficacy of a brief, novel, theory-driven, self-guided, home-based intervention designed to promote condom use among young men who have sex with men (YMSM). Participants: Thirty YMSM were recruited from a large public US midwestern university during spring of 2012. Methods: The intervention was tested using a…
Radiologic Percutaneous Gastrostomy in Nondistended Stomach: A Modified Approach
DOE Office of Scientific and Technical Information (OSTI.GOV)
Petrocelli, Francesco, E-mail: francesco.petrocelli@hsanmartino.it; Salsano, Giancarlo, E-mail: giancarlo.salsano@yahoo.it; Bovio, Giulio, E-mail: giulio.bovio@hsanmartino.it
IntroductionGastrostomy tube placement for patients requiring long-term nutritional support may be performed using different techniques including endoscopic, surgical, and percutaneous radiologically guided methods. Radiologically inserted gastrostomy (RIG), typically performed when percutaneous endoscopic gastrostomy is not possible, requires proper gastric distension that is achieved by insufflating air through a nasogastric tube. We describe a simple technique to prevent air escape from the stomach during gastrostomy tube placement. To the best of our knowledge, this technique has not yet been described in the literature.Materials and MethodsFour patients with unsuccessful percutaneous endoscopic gastrostomy were referred for fluoroscopic-guided gastrostomy. One patient had a pyriformmore » sinus tumor and three had an ischemic stroke causing dysphagia. Gastric distention was not achieved in the patients due to air escaping into the bowel during the standard RIG procedure. A modified approach using a balloon catheter inflated in the pylorus to avoid air passing into the duodenum permitted successful RIG.ResultsThe modified RIG procedure was successfully carried out in all cases without complications.DiscussionInadequate air distension of the stomach is an unusual event that causes a failure of gastrostomy tube placement and an increased risk of both major and minor complications. The use of a balloon catheter inflated in the first part of the duodenum prevents the air passage into the bowel allowing the correct positioning of the gastrostomy.« less
Percutaneous Management of Postoperative Duodenal Stump Leakage with Foley Catheter
DOE Office of Scientific and Technical Information (OSTI.GOV)
Oh, Jung Suk, E-mail: oj-cumc@daum.net; Lee, Hae Giu, E-mail: hgleehfh@catholic.ac.kr; Chun, Ho Jong
2013-10-15
Purpose: This study was designed to evaluate retrospectively the safety and efficacy of the percutaneous management of duodenal stump leakage with a Foley catheter after subtotal gastrectomy. Methods: Ten consecutive patients (M:F = 9:1, median age: 64 years) were included in this retrospective study. The duodenal stump leakages were diagnosed in all the patients within a median of 10 days (range, 6-20). At first, the patients underwent percutaneous drainage on the day of or the day after confirmation of the presence of duodenal stump leakage, and then the Foley catheters were replaced at a median of 9 days (range, 6-38)more » after the percutaneous drainage. Results: Foley catheters were placed successfully in the duodenal lumen of all the patients under a fluoroscopic guide. No complication was observed during and after the procedures in all the patients. All of the patients started a regular diet 1 day after the Foley catheter placement. The patients were discharged at a median of 7 days (range, 5-14) after the Foley catheter placement. The catheters were removed in an outpatient clinic 10-58 days (median, 28) after the Foley catheter placement. Conclusions: Fluoroscopy-guided percutaneous Foley catheter placement may be a safe and effective treatment option for postoperative duodenal stump leakage and may allow for shorter hospital stays, earlier oral intake, and more effective control of leakage sites.« less
Value of Examination Under Fluoroscopy for the Assessment of Sacroiliac Joint Dysfunction.
Eskander, Jonathan P; Ripoll, Juan G; Calixto, Frank; Beakley, Burton D; Baker, Jeffrey T; Healy, Patrick J; Gunduz, O H; Shi, Lizheng; Clodfelter, Jamie A; Liu, Jinan; Kaye, Alan D; Sharma, Sanjay
2015-01-01
Pain emanating from the sacroiliac (SI) joint can have variable radiation patterns. Single physical examination tests for SI joint pain are inconsistent with multiple tests increasing both sensitivity and specificity. To evaluate the use of fluoroscopy in the diagnosis of SI joint pain. Prospective double blind comparison study. Pain clinic and radiology setting in urban Veterans Administration (VA) in New Orleans, Louisiana. Twenty-two adult men, patients at a southeastern United States VA interventional pain clinic, presented with unilateral low back pain of more than 2 months' duration. Patients with previous back surgery were excluded from the study. Each patient was given a Gapping test, Patrick (FABERE) test, and Gaenslen test. A second blinded physician placed each patient prone under fluoroscopic guidance, asking each patient to point to the most painful area. Pain was provoked by applying pressure with the heel of the palm in that area to determine the point of maximum tenderness. The area was marked with a radio-opaque object and was placed on the mark with a fluoroscopic imgage. A site within 1 cm of the SI joint was considered as a positive test. This was followed by a diagnostic injection under fluoroscopy with 1 mL 2% lidocaine. A positive result was considered as more than 2 hours of greater than 75% reduction in pain. Then, in 2-3 days this was followed by a therapeutic injection under fluoroscopy with 1 mL 0.5% bupivacaine and 40 mg methylprednisolone. Each patient was reassessed after 6 weeks. The sensitivity and specificity in addition to the positive and negative predictive values were determined for both the conventional examinations, as well as the examination under fluoroscopy. Finally, a receiver operating characteristic (ROC) curve was constructed to evaluate test performance. The sensitivity and specificity of the fluoroscopic examination were 0.82 and 0.80 respectively; Positive predictive value and negative predictive value were 0.93 and 0.57 respectively. The area under ROC curve was 0.812 which is considered a "good" test; however the area under ROC for the conventional examination were between 0.52-0.58 which is considered "poor to fail". Variation in anatomy of the SI joint, small sample size. Multiple structures of the SI joint complex can result in clinical symptoms of pain. These include intra-articular structures (degenerative arthritis, and inflammatory conditions) as well as extra-articular structures (ligaments, muscles, etc.).
Aubry, S; Pousse, A; Sarliève, P; Laborie, L; Delabrousse, E; Kastler, B
2006-11-01
To model vertebrae in 3D to improve radioanatomic knowledge of the spine with the vascular and nerve environment and simulate CT-guided interventions. Vertebra acquisitions were made with multidetector CT. We developed segmentation software and specific viewer software using the Delphi programming environment. This segmentation software makes it possible to model 3D high-resolution segments of vertebrae and their environment from multidetector CT acquisitions. Then the specific viewer software provides multiplanar reconstructions of the CT volume and the possibility to select different 3D objects of interest. This software package improves radiologists' radioanatomic knowledge through a new 3D anatomy presentation. Furthermore, the possibility of inserting virtual 3D objects in the volume can simulate CT-guided intervention. The first volumetric radioanatomic software has been born. Furthermore, it simulates CT-guided intervention and consequently has the potential to facilitate learning interventions using CT guidance.
Occupational and patient exposure in coronary angiography procedures
NASA Astrophysics Data System (ADS)
Sulieman, A.; Alzimami, K.; Gafar, R.; Babikir, E.; Alsafi, K.; Suliman, I. I.
2014-11-01
Cardiac catheterization is the gold standard in the diagnosis and management of coronary artery diseases. The objectives of this study were to evaluate the radiation dose of patients and staff during cardiology procedures. Staff was monitored using thermoluminescence dosimeter (TLD) chips for 86 procedures. The mean patient dose was 2813.6 μGy m2 and the mean fluoroscopic time was 4.8 min. The mean radiation doses for cardiologists were 0.9 mGy for the forehead, 0.92 mGy for the thyroid, 1.38 mGy for the chest, 1.28 mGy for the waist and 1.41 mGy for the hand. The mean radiation doses for assistants were 0.72 mGy for the chest, 0.82 mGy for the hand. High patient and staff exposure is due to lack of experience and protective equipment, exacerbated by a high workload. Interventional procedures remain operator dependent; therefore, continuous training is crucial.
[CT-guided intervention by means of a laser marking and targeting aid].
Klöppel, R; Wilke, W; Weisse, T; Steinecke, R
1997-08-01
The present study evaluates the use of a laser guidance system for CT-guided intervention. 94 cases of diagnostic biopsies and lumbar sympathectomies (54 cases with laser guidance system and 40 without) were compared. Using the laser guidance system, the number of control scans decreased by 30 to 50%, and necessary corrections of needle location were reduced by a maximum of 30%. The average target deviation of the needle decreased to less than 5 mm in 50% of cases. The laser guidance system is strongly recommended in CT-guided interventions for quality assurance and higher efficiency. The advantage is especially marked if the target area is small.
ERIC Educational Resources Information Center
Hyndman, Brendon P; Benson, Amanda C.; Telford, Amanda
2014-01-01
Despite an increase in the provision of effective school-based interventions in recent times, there is an absence of literature for teachers focusing on the translation of promising interventions into real-world practice. The aim of this research was to provide a social-ecological guide for teachers of the external validity of implementing the…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Szczykutowicz, Timothy P., E-mail: tszczykutowicz@uwhealth.org; Department of Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin 53705; Department of Biomedical Engineering, University of Wisconsin-Madison, Madison, Wisconsin 53706
2016-02-15
Purpose: Accurate CT radiograph angle is not usually important in diagnostic CT. However, there are applications in radiation oncology and interventional radiology in which the orientation of the x-ray source and detector with respect to the patient is clinically important. The authors present a method for measuring the accuracy of the tube/detector assembly with respect to the prescribed tube/detector position for CT localizer, fluoroscopic, and general radiograph imaging using diagnostic, mobile, and c-arm based CT systems. Methods: A mathematical expression relating the x-ray projection of two metal BBs is related to gantry angle. Measurement of the BBs at a prescribedmore » gantry (i.e., c-arm) angle can be obtained and using this relation the prescribed versus actual gantry angle compared. No special service mode or proprietary information is required, only access to projection images is required. Projection images are available in CT via CT localizer radiographs and in the interventional setting via fluorography. Results: The technique was demonstrated on two systems, a mobile CT scanner and a diagnostic CT scanner. The results confirmed a known issue with the mobile scanner and accurately described the CT localizer angle of the diagnostic system tested. Conclusions: This method can be used to quantify gantry angle, which is important when projection images are used for procedure guidance, such as in brachytherapy and interventional radiology applications.« less
Shirota, Ayumi; Nomura, Tetsuya; Kubota, Hiroshi; Taminishi, Shunta; Urata, Ryota; Sugimoto, Takeshi; Higuchi, Yusuke; Kato, Taku; Keira, Natsuya; Tatsumi, Tetsuya
2015-07-28
Because of the unusual anatomy of an anomalous origin of the right coronary artery from the left sinus of Valsalva, selective cannulation of the guiding catheter in percutaneous coronary intervention for these cases is always challenging. A 58-year-old Japanese man was admitted to our hospital complaining of worsening exertional chest pain. He was suspected of having unstable angina pectoris and underwent cardiac catheterization. We found a subtotal occlusive lesion in the mid-portion of his right coronary artery that originated from the left sinus of Valsalva. On the previous percutaneous coronary intervention, we failed to cannulate the guiding catheter to the anomalous orifice of the right coronary artery. Therefore, we decided to use the GuideLiner catheter for stable back-up support from the beginning. A 6Fr GuideLiner catheter was introduced into the right coronary artery by anchoring it coaxially with a semi-compliant balloon catheter. And we successfully deployed two drug-eluting stents by crossing over the posterior-descending artery. Final angiography demonstrated favorable dilatation of the target lesion, and native blood flow in the right coronary artery was completely recovered. GuideLiner is a monorail-type "child" support catheter that facilitates coaxial guiding catheter engagement and an appropriate back-up force, achieving successful device delivery to target lesions in this kind of complex percutaneous coronary intervention.
Principles for Designing Intervention in Mathematics
ERIC Educational Resources Information Center
National Center on Intensive Intervention, 2016
2016-01-01
The purpose of this guide is to provide brief explanations of practices that can be implemented when working with students in need of intensive intervention in mathematics. Special education instructors, math interventionists, and others working with students who struggle with mathematics may find this guide helpful. Specific topics covered…
GuideLiner™ as guide catheter extension for the unreachable mammary bypass graft.
Vishnevsky, Alec; Savage, Michael P; Fischman, David L
2018-03-09
Percutaneous coronary intervention (PCI) of mammary artery bypass grafts through a trans-radial (TR) approach can present unique challenges, including coaxial vessel engagement of the guiding catheter, adequate visualization of the target lesion, sufficient backup support for equipment delivery, and the ability to reach very distal lesions. The GuideLiner catheter, a rapid exchange monorail mother-in-daughter system, facilitates successful interventions in such challenging anatomy. We present a case of a patient undergoing PCI of a right internal mammary artery (RIMA) graft via TR access in whom the graft could not be engaged with any guiding catheter. Using a balloon tracking technique over a guidewire, a GuideLiner was placed as an extension of the guiding catheter and facilitated TR-PCI by overcoming technical challenges associated with difficult anatomy. © 2018 Wiley Periodicals, Inc.
2014-01-01
Background There is an urgent need for innovative and developmentally appropriate lifestyle interventions to promote healthy lifestyle behaviors and to prevent the early onset of type 2 diabetes and cardiovascular disease risk in obese Latino adolescents. Guided imagery offers promise to reduce stress and promote lifestyle behavior change to reduce disease risk in obese adolescents. Our objectives were: 1) To pilot test a new 12-wk lifestyle intervention using a randomized trial design in obese Latino adolescents, in order to determine the effects of the mind-body modality of Interactive Guided ImagerySM (IGI), over and above those of a didactic lifestyle education, on insulin resistance, eating and physical activity behaviors, stress and stress biomarkers; and 2) To explore the role of intervention-related changes in stress and stress biomarkers on changes in metabolic outcomes, particularly insulin resistance. Methods Obese (BMI > 95th percentile), Latino adolescents (n = 35, age 14-17) were randomized to receive either 12 weekly sessions of a lifestyle education plus guided imagery program (GI), or lifestyle education plus a digital storytelling computer program (DS). Between-group differences in behavioral, biological, and psychological outcomes were assessed using unpaired T-tests and ANCOVA in the 29 subjects who completed the intervention. Results The GI group demonstrated significant reductions in leisure sedentary behavior (p < .05) and increases in moderate physical activity (p < .05) compared to DS group, and a trend toward reduced caloric intake in GI vs DS (p = .09). Salivary cortisol was acutely reduced by stress-reduction guided imagery (p < .01). There were no group differences in adiposity, insulin resistance, perceived stress, or stress biomarkers across the 12-week intervention, though decrease in serum cortisol over the course of the intervention was associated with improved insulin sensitivity (p = .03) independent of intervention group and other relevant co-variates. Conclusions The improvements in physical activity and stress biomarkers following this pilot intervention support the role of guided imagery in promoting healthy lifestyle behavior change and reducing metabolic disease risk in obese Latino adolescent populations. Future investigations will be needed to determine the full effects of the Imagine HEALTH intervention on insulin resistance, stress, and stress biomarkers. Trial registration Clinicaltrials.gov Registry #: NCT01895595 PMID:24433565
Shilts, Mical Kay; Horowitz, Marcel; Townsend, Marilyn S
2009-01-01
Determining the effectiveness of the guided goal setting strategy on changing adolescents' dietary and physical activity self-efficacy and behaviors. Adolescents were individually assigned to treatment (intervention with guided goal setting) or control conditions (intervention without guided goal setting) with data collected before and after the education intervention. Urban middle school in a low-income community in Central California. Ethnically diverse middle school students (n = 94, 55% male) who were participants of a USDA nutrition education program. Driven by the Social Cognitive Theory, the intervention targeted dietary and physical activity behaviors of adolescents. Dietary self-efficacy and behavior; physical activity self-efficacy and behavior; goal effort and spontaneous goal setting. ANCOVA and path analysis were performed using the full sample and a sub-sample informed by Locke's recommendations (accounting for goal effort and spontaneous goal setting). No significant differences were found between groups using the full sample. Using the sub-sample, greater gains in dietary behavior (p < .05), physical activity behavior (p < .05), and physical activity self-efficacy (p < .05) were made by treatment participants compared to control participants. Change in physical activity behaviors was mediated by self-efficacy. Accounting for goal effort and spontaneous goal setting, this study provides some evidence that the use of guided goal setting with adolescents may be a viable strategy to promote dietary and physical activity behavior change.
Reinforcing the role of the conventional C-arm--a novel method for simplified distal interlocking.
Windolf, Markus; Schroeder, Josh; Fliri, Ladina; Dicht, Benno; Liebergall, Meir; Richards, R Geoff
2012-01-25
The common practice for insertion of distal locking screws of intramedullary nails is a freehand technique under fluoroscopic control. The process is technically demanding, time-consuming and afflicted to considerable radiation exposure of the patient and the surgical personnel. A new concept is introduced utilizing information from within conventional radiographic images to help accurately guide the surgeon to place the interlocking bolt into the interlocking hole. The newly developed technique was compared to conventional freehand in an operating room (OR) like setting on human cadaveric lower legs in terms of operating time and radiation exposure. The proposed concept (guided freehand), generally based on the freehand gold standard, additionally guides the surgeon by means of visible landmarks projected into the C-arm image. A computer program plans the correct drilling trajectory by processing the lens-shaped hole projections of the interlocking holes from a single image. Holes can be drilled by visually aligning the drill to the planned trajectory. Besides a conventional C-arm, no additional tracking or navigation equipment is required.Ten fresh frozen human below-knee specimens were instrumented with an Expert Tibial Nail (Synthes GmbH, Switzerland). The implants were distally locked by performing the newly proposed technique as well as the conventional freehand technique on each specimen. An orthopedic resident surgeon inserted four distal screws per procedure. Operating time, number of images and radiation time were recorded and statistically compared between interlocking techniques using non-parametric tests. A 58% reduction in number of taken images per screw was found for the guided freehand technique (7.4 ± 3.4) (mean ± SD) compared to the freehand technique (17.6 ± 10.3) (p < 0.001). Total radiation time (all 4 screws) was 55% lower for the guided freehand technique compared to conventional freehand (p = 0.001). Operating time per screw (from first shot to screw tightened) was on average 22% reduced by guided freehand (p = 0.018). In an experimental setting, the newly developed guided freehand technique for distal interlocking has proven to markedly reduce radiation exposure when compared to the conventional freehand technique. The method utilizes established clinical workflows and does not require cost intensive add-on devices or extensive training. The underlying principle carries potential to assist implant positioning in numerous other applications within orthopedics and trauma from screw insertions to placement of plates, nails or prostheses.
Occupational dose in interventional radiology procedures.
Chida, Koichi; Kaga, Yuji; Haga, Yoshihiro; Kataoka, Nozomi; Kumasaka, Eriko; Meguro, Taiichiro; Zuguchi, Masayuki
2013-01-01
Interventional radiology tends to involve long procedures (i.e., long fluoroscopic times). Therefore, radiation protection for interventional radiology staff is an important issue. This study describes the occupational radiation dose for interventional radiology staff, especially nurses, to clarify the present annual dose level for interventional radiology nurses. We compared the annual occupational dose (effective dose and dose equivalent) among interventional radiology staff in a hospital where 6606 catheterization procedures are performed annually. The annual occupational doses of 18 physicians, seven nurses, and eight radiologic technologists were recorded using two monitoring badges, one worn over and one under their lead aprons. The annual mean ± SD effective dose (range) to the physicians, nurses, and radiologic technologists using two badges was 3.00 ± 1.50 (0.84-6.17), 1.34 ± 0.55 (0.70-2.20), and 0.60 ± 0.48 (0.02-1.43) mSv/y, respectively. Similarly, the annual mean ± SD dose equivalent range was 19.84 ± 12.45 (7.0-48.5), 4.73 ± 0.72 (3.9-6.2), and 1.30 ± 1.00 (0.2-2.7) mSv/y, respectively. The mean ± SD effective dose for the physicians was 1.02 ± 0.74 and 3.00 ± 1.50 mSv/y for the one- and two-badge methods, respectively (p < 0.001). Similarly, the mean ± SD effective dose for the nurses (p = 0.186) and radiologic technologists (p = 0.726) tended to be lower using the one-badge method. The annual occupational dose for interventional radiology staff was in the order physicians > nurses > radiologic technologists. The occupational dose determined using one badge under the apron was far lower than the dose obtained with two badges in both physicians and nonphysicians. To evaluate the occupational dose correctly, we recommend use of two monitoring badges to evaluate interventional radiology nurses as well as physicians.
Resource Guide: Selected Early Childhood/Early Intervention Training Materials. 8th Edition.
ERIC Educational Resources Information Center
Catlett, Camille, Comp.; Winton, Pamela J., Comp.
This resource guide is intended to identify both primary and supplementary resources for designing preservice and inservice training on early intervention programs for children with disabilities. The instructional materials are described and listed in three sections. The first section provides annotated descriptions of instructional materials in…
Accelerated Reader/Reading Renaissance. What Works Clearinghouse Intervention Report
ERIC Educational Resources Information Center
What Works Clearinghouse, 2007
2007-01-01
The Accelerated Reader/Reading Renaissance program (now called Accelerated Reader Best Classroom Practices) is a guided reading intervention in which teachers direct student reading of text. It involves two components. Reading Renaissance, the first component, is a set of recommended principles on guided reading (or teachers' direction of…
PET/CT-guided interventions: Indications, advantages, disadvantages and the state of the art.
Cazzato, Roberto Luigi; Garnon, Julien; Shaygi, Behnam; Koch, Guillaume; Tsoumakidou, Georgia; Caudrelier, Jean; Addeo, Pietro; Bachellier, Philippe; Namer, Izzie Jacques; Gangi, Afshin
2018-02-01
Positron emission tomography/computed tomography (PET/CT) represents an emerging imaging guidance modality that has been applied to successfully guide percutaneous procedures such as biopsies and tumour ablations. The aim of the present narrative review is to report the indications, advantages and disadvantages of PET/CT-guided procedures in the field of interventional oncology and to briefly describe the experience gained with this new emerging technique while performing biopsies and tumor ablations.
Rinninella, Emanuele; Kunda, Rastislav; Dollhopf, Markus; Sanchez-Yague, Andres; Will, Uwe; Tarantino, Ilaria; Gornals Soler, Joan; Ullrich, Sebastian; Meining, Alexander; Esteban, Josè Miguel; Enz, Thomas; Vanbiervliet, Geoffroy; Vleggaar, Frank; Attili, Fabia; Larghi, Alberto
2015-12-01
A lumen-apposing, self-expanding metal stent incorporated in an electrocautery-enhanced delivery system for EUS-guided drainage of pancreatic fluid collections (PFCs) recently has become available. The aim of this study was to analyze the safety and clinical effectiveness of this newly developed device in this clinical setting. This was a retrospective analysis of all consecutive patients with PFCs who underwent EUS-guided drainage using the study device in 13 European centers. Ninety-three patients with PFCs (80% with complex collections) underwent drainage using the study device. Penetration of the PFC was accomplished directly with the study device in 74.2% of patients, and successful stent placement was accomplished in all but 1 patient, mostly without fluoroscopic assistance. Direct endoscopic necrosectomy (DEN) was carried out in 31 of 52 cases (59.6%) of walled-off necrosis and in 2 of 4 cases (50%) of acute peripancreatic fluid collection. Complete resolution of the PFC was obtained in 86 cases (92.5%), with no recurrence during follow-up. Treatment failure occurred in 6 patients because of persistent infection requiring surgery (n = 3), perforation and massive bleeding caused by the nasocystic drainage catheter (NCDC) (n = 2), and the need for a larger opening to extract large necrotic tissue pieces (n = 1). Major adverse events occurred in 5 patients (perforation and massive bleeding caused by the NCDC in 2 patients, 1 pneumoperitoneum and 1 stent dislodgement during DEN, and 1 postdrainage infection) and were mostly not related to the drainage procedure. EUS-guided drainage with the electrocautery-enhanced delivery system is a safe, easy to perform, and a highly effective minimally invasive treatment modality for PFCs. Copyright © 2015 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.
Rhodes, Scott D; Mann-Jackson, Lilli; Alonzo, Jorge; Simán, Florence M; Vissman, Aaron T; Nall, Jennifer; Abraham, Claire; Aronson, Robert E; Tanner, Amanda E
2017-12-01
The science underlying the development of individual, community, system, and policy interventions designed to reduce health disparities has lagged behind other innovations. Few models, theoretical frameworks, or processes exist to guide intervention development. Our community-engaged research partnership has been developing, implementing, and evaluating efficacious interventions to reduce HIV disparities for over 15 years. Based on our intervention research experiences, we propose a novel 13-step process designed to demystify and guide intervention development. Our intervention development process includes steps such as establishing an intervention team to manage the details of intervention development; assessing community needs, priorities, and assets; generating intervention priorities; evaluating and incorporating theory; developing a conceptual or logic model; crafting activities; honing materials; administering a pilot, noting its process, and gathering feedback from all those involved; and editing the intervention based on what was learned. Here, we outline and describe each of these 13 steps.
Klein, Jan Thorsten; Rassweiler, Jens; Rassweiler-Seyfried, Marie-Claire Charlotte
2018-03-29
Nephrolithiasis is one of the most common diseases in urology. According to the EAU Guidelines, a percutaneous nephrolitholapaxy (PNL) is recommended when treating a kidney stone >2 cm. Nowadays PNL is performed even for smaller stones (<1 cm) using miniaturized instruments. The most challenging part of any PNL is the puncture of the planned site. PNL-novice surgeons need to practice this step in a safe environment with an ideal training model. We developed and evaluated a new, easy to produce, in-vitro model for the training of the freehand puncture of the kidney. Porcine kidneys with ureters were embedded in ballistic gel. Food coloring and preservative agent were added. We used the standard imaging modalities of X-ray and ultrasound to validate the training model. An additional new technique, the iPAD guided puncture, was evaluated. Five novices and three experts conducted 12 punctures for each imaging technique. Puncture time, radiation dose, and number of attempts to a successful puncture were measured. Mann-Whitney-U, Kruskal-Wallis, and U-Tests were used for statistical analyses. The sonographic guided puncture is slightly but not significantly faster than the fluoroscopic guided puncture and the iPAD assisted puncture. Similarly, the most experienced surgeon's time for a successful puncture was slightly less than that of the residents, and the experienced surgeons needed the least attempts to perform a successful puncture. In terms of radiation exposure, the residents had a significant reduction of radiation exposure compared to the experienced surgeons. The newly developed ballistic gel kidney-puncture model is a good training tool for a variety of kidney puncture techniques, with good content, construct, and face validity.
Stone, Jonathan; Matchett, Gerald
2014-01-01
Management of pain from skeletal metastases is notoriously difficult. Case reports and case series have described radiofrequency ablation of the obturator nerve branches to the femoral head for treatment of intractable hip pain. Ablation of the obturator branches to the femoral head is technically difficult because of bony and vascular anatomy, including close proximity of the femoral vessels. Here we present the case of a 79-year-old woman with intractable right hip pain and inability to ambulate secondary to metastatic non-small cell lung cancer in the femoral head and acetabulum, treated with thermal radiofrequency ablation of the obturator and femoral nerve branches to the femoral head. Ablation of the obturator nerve was done via anterior placement of the radiofrequency needle under combined ultrasound and fluoroscopic guidance, passing the radiofrequency needle between the femoral artery and femoral vein. Real-time ultrasound guidance was used to avoid vascular puncture. Thermal radiofrequency ablation resulted in sustained pain relief, and resumption in the ability of the patient to ambulate. From this case we suggest that an anterior approach to the obturator nerve branches to the femoral head may be technically feasible using combined ultrasound and fluoroscopic guidance to avoid vascular puncture.
Intraoperative CT in the assessment of posterior wall acetabular fracture stability.
Cunningham, Brian; Jackson, Kelly; Ortega, Gil
2014-04-01
Posterior wall acetabular fractures that involve 10% to 40% of the posterior wall may or may not require an open reduction and internal fixation. Dynamic stress examination of the acetabular fracture under fluoroscopy has been used as an intraoperative method to assess joint stability. The aim of this study was to demonstrate the value of intraoperative ISO computed tomography (CT) examination using the Siemens ISO-C imaging system (Siemens Corp, Malvern, Pennsylvania) in the assessment of posterior wall acetabular fracture stability during stress examination under anesthesia. In 5 posterior wall acetabular fractures, standard fluoroscopic images (including anteroposterior pelvis and Judet radiographs) with dynamic stress examinations were compared with the ISO-C CT imaging system to assess posterior wall fracture stability during stress examination. After review of standard intraoperative fluoroscopic images under dynamic stress examination, all 5 cases appeared to demonstrate posterior wall stability; however, when the intraoperative images from the ISO-C CT imaging system demonstrated that 1 case showed fracture instability of the posterior wall segment during stress examination, open reduction and internal fixation was performed. The use of intraoperative ISO CT imaging has shown an initial improvement in the surgeon's ability to assess the intraoperative stability of posterior wall acetabular fractures during stress examination when compared with standard fluoroscopic images. Copyright 2014, SLACK Incorporated.
Avcı, Cem Coşkun; Gülabi, Deniz; Sağlam, Necdet; Kurtulmuş, Tuhan; Saka, Gürsel
2013-01-01
This study aims to investigate the efficacy of screw length measurement through drilling technique on the reduction of intraarticular screw penetration and fluoroscopy time in osteosynthesis of proximal humerus fractures. Between January 2008 and June 2012, 98 patients (34 males, 64 females; mean age 64.4 years; range 35 to 81 years) who underwent osteosynthesis using locking anatomical proximal humerus plates (PHILOS) in our clinic with the diagnosis of Neer type 2, 3 or 4 were included. Two different surgical techniques were used to measure proximal screw length in the plate and patients were divided into two groups based on the technique used. In group 1, screw length was determined by a 3 mm blunt tipped Kirschner wire without fluoroscopic control. In group 2, bilateral fluoroscopic images for each screw at least were obtained. Intraarticular screw penetration was detected in five patients (10.6%) in group 1, and in 19 patients (37.3%) in group 2. The mean fluoroscopic imaging time was 10.6 seconds in group 1 and 24.8 seconds in group 2, indicating a statistically significant difference. Screw length measurement through the drilling technique significantly reduces the intraarticular screw penetration and fluoroscopy time in osteosynthesis of proximal humerus fractures using PHILOS plates.
Park, Samuel Byeongjun; Kim, Jung-Gun; Lim, Ki-Woong; Yoon, Chae-Hyun; Kim, Dong-Jun; Kang, Han-Sung; Jo, Yung-Ho
2017-08-01
We developed an image-guided intervention robot system that can be operated in a magnetic resonance (MR) imaging gantry. The system incorporates a bendable needle intervention robot for breast cancer patients that overcomes the space limitations of the MR gantry. Most breast coil designs for breast MR imaging have side openings to allow manual localization. However, for many intervention procedures, the patient must be removed from the gantry. A robotic manipulation system with integrated image guidance software was developed. Our robotic manipulator was designed to be slim, so as to fit between the patient's side and the MR gantry wall. Only non-magnetic materials were used, and an electromagnetic shield was employed for cables and circuits. The image guidance software was built using open source libraries. In situ feasibility tests were performed in a 3-T MR system. One target point in the breast phantom was chosen by the clinician for each experiment, and our robot moved the needle close to the target point. Without image-guided feedback control, the needle end could not hit the target point (distance = 5 mm) in the first experiment. Using our robotic system, the needle hits the target lesion of the breast phantom at a distance of 2.3 mm from the same target point using image-guided feedback. The second experiment was performed using other target points, and the distance between the final needle end point and the target point was 0.8 mm. We successfully developed an MR-guided needle intervention robot for breast cancer patients. Further research will allow the expansion of these interventions.
Axelsson, Christen K; Ballegaard, Søren; Karpatschof, Benny; Schousen, Peer
2014-08-01
To validate (1) Pressure Pain Sensitivity (PPS) as a marker for stress and (2) a PPS-guided intervention in women with primary Breast Cancer (BC). (1) A total of 58 women with BC were examined before and after 6 months of intervention. A control group of 165 women office employees was divided in a High Stress Group (HSG, n = 37) and a Low Stress Group (LSG, n = 128) to evaluate the association between PPS, questionnaire-related Quality of Life (QOL) and self-evaluated stress. (2) A PPS-guided stress management program (n = 40) was compared to a Psychosocial Group Intervention (PGI, n = 91) and no treatment (n = 86) with respect to a European Organization for Research and Treatment of Cancer (EORTC) questionnaire measured QOL. (1) Resting PPS and changes in PPS during the intervention period correlated significantly to EORTC and Short Form 36 (SF 36) main scores: (all p < 0.05). Between BC, HSG and LSG there was a significant and positive correlation with respect to PPS, SF 36 main scores, depression, and clinical stress scores (all p < 0.05). However, the BC group scored significantly lower than both HSG and LSG (both p < 0.05) with respect to self-evaluated stress. (2) The PPS-guided intervention group improved EORTC main score, pain and nausea, when compared to the control groups (all p < 0.05). PPS was positively associated with QOL, which was in contrast to self-evaluated stress. PPS-guided intervention improved QOL in women with breast cancer.
Prasarn, Mark L; Coyne, Ellen; Schreck, Michael; Rodgers, Jamie D; Rechtine, Glenn R
2013-07-15
Cadaveric imaging study. We sought to compare the fluoroscopic images produced by 4 different fluoroscopes for image quality and radiation exposure when used for imaging the spine. There are no previous published studies comparing mobile C-arm machines commonly used in clinical practice for imaging the spine. Anterior-posterior and lateral images of the cervical, thoracic, and lumbar spine were obtained from a cadaver placed supine on a radiolucent table. The fluoroscopy units used for the study included (1) GE OEC 9900 Elite (2010 model; General Electric Healthcare, Waukesha, WI), (2) Philips BV Pulsera (2009 model; Philips Healthcare, Andover, MA), (3) Philips BV Pulsera (2010 model; Philips Healthcare, Andover, MA), and (4) Siemens Arcadis Avantic (2010 model; Siemens Medical Solutions, Malvern, PA). The images were then downloaded, placed into a randomizer program, and evaluated by a group of spine surgeons and neuroradiologists independently. The reviewers, who were blinded to the fluoroscope the images were from, ranked them from best to worst using a numeric system. In addition, the images were rated according to a quality scale from 1 to 5, with 1 representing the best image quality. The radiation exposure level for the fluoroscopy units was also compared and was based on energy emission. According to the mean values for rank, the following order of best to worst was observed: (1) GE OEC > (2) Philips 2010 > (3) Philips 2009 > (4) Siemans. The exact same order was found when examining the image quality ratings. When comparing the radiation exposure level difference, it was observed that the OEC was the lowest, and there was a minimum 30% decrease in energy emission from the OEC versus the other C-arms studied. This is the first time that the spine image quality and radiation exposure of commonly used C-arm machines have been compared. The OEC was ranked the best, produced the best quality images, and had the least amount of radiation.
Jalali, Maryam; Farahmand, Farzam; Mousavi, Seyed Mohammad Ebrahim; Golestanha, Seyed Ali; Rezaeian, Tahmineh; Shirvani Broujeni, Shahram; Rahgozar, Mehdi; Esfandiarpour, Fateme
2015-07-01
Despite several studies with different methods, the effect of functional knee braces on knee joint kinematics is not clear. Direct visualization of joint components through medical imaging modalities may provide the clinicians with more useful information. In this study, for the first time in the literature, video fluoroscopy was used to investigate the effect of knee bracing on the sagittal plane kinematics of anterior cruciate ligament (ACL) injured patients. For twelve male unilateral ACL deficient subjects, the anterior tibial translation was measured during lunge exercise in non-braced and braced conditions. Fluoroscopic images were acquired from the subjects using a digital fluoroscopy system with a rate of 10 fps. The image of each frame was scaled using a calibration coin and analyzed in AutoCAD environment. The angle between the two lines, tangent to the posterior cortexes of the femoral and tibial shafts was measured as the flexion angle. For the fluoroscopic images associated with 0°, 15°, 30°, 45° and 60° knee flexion angles, the relative anterior-posterior configuration of the tibiofemoral joint was assessed by measuring the position of landmarks on the tibia and femur. Results indicated that the overall anterior translations of the tibia during the eccentric (down) and concentric (up) phases of lunge exercise were 10.4 ± 1.7 mm and 9.0 ± 2.2 mm for non-braced, and 10.1 ± 3.4 mm and 7.4 ± 2.5 mm, for braced conditions, respectively. The difference of the tibial anterior-posterior translation behaviors of the braced and non-braced knees was not statistically significant. Fluoroscopic imaging provides an effective tool to measure the dynamic behavior of the knee joint in the sagittal plane and within the limitations of this study, the pure mechanical stabilizing effect of functional knee bracing is not sufficient to control the anterior tibial translation of the ACL deficient patients during lunge exercise.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wunderle, K; Wayne State University School of Medicine, Detroit, MI; Godley, A
Purpose: The purpose of this investigation is to characterize and quantify X-ray beam profiles for fluoroscopic x-ray beam spectra incorporating spectral (copper) filtration. Methods: A PTW (Freiburg, Germany) type 60016 silicon diode detector and PTW MP3 water tank were used to measure X-ray beam profiles for 60, 80, 100 and 120 kVp x-ray beams at five different copper filtration thicknesses ranging from 0–0.9 mm at 22 and 42 cm fields of view and depths of 1, 5, and 10 cm in both the anode-cathode axis (inplane) and cross-plane directions. All measurements were acquired on a Siemens (Erlangen, Germany) Artis ZeeGomore » fluoroscope inverted from the typical orientation providing an x-ray beam originating from above the water surface with the water level set at 60 cm from the focal spot. Results: X-ray beam profiles for beam spectra without copper filtration compared well to previously published data by Fetterly et al. [Med Phys, 28, 205 (2001)]. Our data collection benefited from the geometric orientation of the fluoroscope, providing a beam perpendicular to the tank water surface, rather than through a thin side wall as did the previously mentioned study. Profiles for beams with copper filtration were obtained which have not been previously investigated and published. Beam profiles in the anode-cathode axis near the surface and at lower x-ray energy exhibited substantial heel effect, which became less pronounced at greater depth. At higher energy with copper filtration in the beam, the dose falloff out-of-field became less pronounced, as would be anticipated given higher scatter photon energy. Conclusion: The x-ray beam profile data for the fluoroscopic x-ray beams incorporating copper filtration are intended for use as reference data for estimating doses to organs or soft tissue, including fetal dose, involving similar beam qualities or for comparison with mathematical models.« less
SU-D-209-01: Can Fluoroscopic Air-Kerma Rates Be Reliably Measured with Solid-State Meters?
DOE Office of Scientific and Technical Information (OSTI.GOV)
Feng, C; Thai, L; Wagner, L
Purpose: Ionization chambers remain the standard for calibration of air-kerma rate measuring devices. Despite their strong energy-dependent response, solid state radiation detectors are increasingly used, primarily due to their efficiency in making standardized measurements. To test the reliability of these devices in measuring air-kerma rates, we compared ion chambers measurements with solid-state measurements for various mobile fluoroscopes operated at different beam qualities and air-kerma rates. Methods: Six mobile fluoroscopes (GE OEC models 9800 and 9900) were used to generate test beams. Using various field sizes and dose rate controls, copper attenuators and a lead attenuator were placed at the imagemore » receptor in varying combinations to generate a range of air-kerma rates. Air-kerma rates at 30 centimeters from the image receptors were measured using two 6-cm{sup 3} ion chambers with electrometers (Radcal, models 1015 and 9015) and two with solid state detectors (Unfors Xi and Raysafe X2). No error messages occurred during measurements. However, about two months later, one solid-state device stopped working and was replaced by the manufacturer. Two out of six mobile fluoroscopic units were retested with the replacement unit. Results: Generally, solid state and ionization chambers agreed favorably well, with two exceptions. Before replacement of the detector, the Xi meter when set in the “RF High” mode deviated from ion chamber readings by factors of 2 and 10 with no message indicating error in measurement. When set in the “RF Low” mode, readings were within −4% to +3%. The replacement Xi detector displayed messages alerting the user when settings were not compatible with air-kerma rates. Conclusion: Air-kerma rates can be measured favorably well using solid-state devices, but users must be aware of the possibility that readings can be grossly in error with no discernible indication for the deviation.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, X; Belcher, AH; Grelewicz, Z
Purpose: Real-time kV fluoroscopic tumor tracking has the benefit of direct tumor position monitoring. However, there is clinical concern over the excess kV imaging dose cost to the patient when imaging in continuous fluoroscopic mode. This work addresses this specific issue by proposing a combined MV+kV direct-aperture optimization (DAO) approach to integrate the kV imaging beam into a treatment planning such that the kV radiation is considered as a contributor to the overall dose delivery. Methods: The combined MV+kV DAO approach includes three algorithms. First, a projected Quasi-Newton algorithm (L-BFGS) is used to find optimized fluence with MV+kV dose formore » the best possible dose distribution. Then, Engel’s algorithm is applied to optimize the total number of monitor units and heuristically optimize the number of apertures. Finally, an aperture shape optimization (ASO) algorithm is applied to locally optimize the leaf positions of MLC. Results: Compared to conventional DAO MV plans with continuous kV fluoroscopic tracking, combined MV+kV DAO plan leads to a reduction in the total number of MV monitor units due to inclusion of kV dose as part of the PTV, and was also found to reduce the mean and maximum doses on the organs at risk (OAR). Compared to conventional DAO MV plan without kV tracking, the OAR dose in the combined MV+kV DAO plan was only slightly higher. DVH curves show that combined MV+kV DAO plan provided about the same PTV coverage as that in the conventional DAO plans without kV imaging. Conclusion: We report a combined MV+kV DAO approach that allows real time kV imager tumor tracking with only a trivial increasing on the OAR doses while providing the same coverage to PTV. The approach is suitable for clinic implementation.« less
Dalum, Peter; Schaalma, Herman; Kok, Gerjo
2012-02-01
The objective of this project was to develop a theory- and evidence-based adolescent smoking cessation intervention using both new and existing materials. We used the Intervention Mapping framework for planning health promotion programmes. Based on a needs assessment, we identified important and changeable determinants of cessation behaviour, specified change objectives for the intervention programme, selected theoretical change methods for accomplishing intervention objectives and finally operationalized change methods into practical intervention strategies. We found that guided practice, modelling, self-monitoring, coping planning, consciousness raising, dramatic relief and decisional balance were suitable methods for adolescent smoking cessation. We selected behavioural journalism, guided practice and Motivational Interviewing as strategies in our intervention. Intervention Mapping helped us to develop as systematic adolescent smoking cessation intervention with a clear link between behavioural goals, theoretical methods, practical strategies and materials and with a strong focus on implementation and recruitment. This paper does not present evaluation data.
Value of MR contrast media in image-guided body interventions.
Saeed, Maythem; Wilson, Mark
2012-01-28
In the past few years, there have been multiple advances in magnetic resonance (MR) instrumentation, in vivo devices, real-time imaging sequences and interventional procedures with new therapies. More recently, interventionists have started to use minimally invasive image-guided procedures and local therapies, which reduce the pain from conventional surgery and increase drug effectiveness, respectively. Local therapy also reduces the systemic dose and eliminates the toxic side effects of some drugs to other organs. The success of MR-guided procedures depends on visualization of the targets in 3D and precise deployment of ablation catheters, local therapies and devices. MR contrast media provide a wealth of tissue contrast and allows 3D and 4D image acquisitions. After the development of fast imaging sequences, the clinical applications of MR contrast media have been substantially expanded to include pre- during- and post-interventions. Prior to intervention, MR contrast media have the potential to localize and delineate pathologic tissues of vital organs, such as the brain, heart, breast, kidney, prostate, liver and uterus. They also offer other options such as labeling therapeutic agents or cells. During intervention, these agents have the capability to map blood vessels and enhance the contrast between the endovascular guidewire/catheters/devices, blood and tissues as well as direct therapies to the target. Furthermore, labeling therapeutic agents or cells aids in visualizing their delivery sites and tracking their tissue distribution. After intervention, MR contrast media have been used for assessing the efficacy of ablation and therapies. It should be noted that most image-guided procedures are under preclinical research and development. It can be concluded that MR contrast media have great value in preclinical and some clinical interventional procedures. Future applications of MR contrast media in image-guided procedures depend on their safety, tolerability, tissue specificity and effectiveness in demonstrating success of the interventions and therapies.
Karyotaki, Eirini; Ebert, David Daniel; Donkin, Liesje; Riper, Heleen; Twisk, Jos; Burger, Simone; Rozental, Alexander; Lange, Alfred; Williams, Alishia D; Zarski, Anna Carlotta; Geraedts, Anna; van Straten, Annemieke; Kleiboer, Annet; Meyer, Björn; Ünlü Ince, Burçin B; Buntrock, Claudia; Lehr, Dirk; Snoek, Frank J; Andrews, Gavin; Andersson, Gerhard; Choi, Isabella; Ruwaard, Jeroen; Klein, Jan Philipp; Newby, Jill M; Schröder, Johanna; Laferton, Johannes A C; Van Bastelaar, Kim; Imamura, Kotaro; Vernmark, Kristofer; Boß, Leif; Sheeber, Lisa B; Kivi, Marie; Berking, Matthias; Titov, Nickolai; Carlbring, Per; Johansson, Robert; Kenter, Robin; Perini, Sarah; Moritz, Steffen; Nobis, Stephanie; Berger, Thomas; Kaldo, Viktor; Forsell, Yvonne; Lindefors, Nils; Kraepelien, Martin; Björkelund, Cecilia; Kawakami, Norito; Cuijpers, Pim
2018-06-19
Little is known about clinically relevant changes in guided Internet-based interventions for depression. Moreover, methodological and power limitations preclude the identification of patients' groups that may benefit more from these interventions. This study aimed to investigate response rates, remission rates, and their moderators in randomized controlled trials (RCTs) comparing the effect of guided Internet-based interventions for adult depression to control groups using an individual patient data meta-analysis approach. Literature searches in PubMed, Embase, PsycINFO and Cochrane Library resulted in 13,384 abstracts from database inception to January 1, 2016. Twenty-four RCTs (4889 participants) comparing a guided Internet-based intervention with a control group contributed data to the analysis. Missing data were multiply imputed. To examine treatment outcome on response and remission, mixed-effects models with participants nested within studies were used. Response and remission rates were calculated using the Reliable Change Index. The intervention group obtained significantly higher response rates (OR = 2.49, 95% CI 2.17-2.85) and remission rates compared to controls (OR = 2.41, 95% CI 2.07-2.79). The moderator analysis indicated that older participants (OR = 1.01) and native-born participants (1.66) were more likely to respond to treatment compared to younger participants and ethnic minorities respectively. Age (OR = 1.01) and ethnicity (1.73) also moderated the effects of treatment on remission.Moreover, adults with more severe depressive symptoms at baseline were more likely to remit after receiving internet-based treatment (OR = 1.19). Guided Internet-based interventions lead to substantial positive treatment effects on treatment response and remission at post-treatment. Thus, such interventions may complement existing services for depression and potentially reduce the gap between the need and provision of evidence-based treatments. Copyright © 2018. Published by Elsevier Ltd.
Lee, Clara; Bolck, Jan; Naguib, Nagy N.N.; Schulz, Boris; Eichler, Katrin; Aschenbach, Rene; Wichmann, Julian L.; Vogl, Thomas. J.; Zangos, Stephan
2015-01-01
Objective To investigate the accuracy, efficiency and radiation dose of a novel laser navigation system (LNS) compared to those of free-handed punctures on computed tomography (CT). Materials and Methods Sixty punctures were performed using a phantom body to compare accuracy, timely effort, and radiation dose of the conventional free-handed procedure to those of the LNS-guided method. An additional 20 LNS-guided interventions were performed on another phantom to confirm accuracy. Ten patients subsequently underwent LNS-guided punctures. Results The phantom 1-LNS group showed a target point accuracy of 4.0 ± 2.7 mm (freehand, 6.3 ± 3.6 mm; p = 0.008), entrance point accuracy of 0.8 ± 0.6 mm (freehand, 6.1 ± 4.7 mm), needle angulation accuracy of 1.3 ± 0.9° (freehand, 3.4 ± 3.1°; p < 0.001), intervention time of 7.03 ± 5.18 minutes (freehand, 8.38 ± 4.09 minutes; p = 0.006), and 4.2 ± 3.6 CT images (freehand, 7.9 ± 5.1; p < 0.001). These results show significant improvement in 60 punctures compared to freehand. The phantom 2-LNS group showed a target point accuracy of 3.6 ± 2.5 mm, entrance point accuracy of 1.4 ± 2.0 mm, needle angulation accuracy of 1.0 ± 1.2°, intervention time of 1.44 ± 0.22 minutes, and 3.4 ± 1.7 CT images. The LNS group achieved target point accuracy of 5.0 ± 1.2 mm, entrance point accuracy of 2.0 ± 1.5 mm, needle angulation accuracy of 1.5 ± 0.3°, intervention time of 12.08 ± 3.07 minutes, and used 5.7 ± 1.6 CT-images for the first experience with patients. Conclusion Laser navigation system improved accuracy, duration of intervention, and radiation dose of CT-guided interventions. PMID:26175571
Improving Early Reading: A Resource Guide for Elementary Schools.
ERIC Educational Resources Information Center
St. John, Edward P.; Loescher, Siri Ann
Indiana's Early Intervention Grant Program (EIGP) provides funding for Reading Recovery and other early interventions focused on improvement in early reading programs (Grades 1-5). This resource guide provides information that schools in Indiana can use to plan for proposals for EIGP and other grant programs, such as comprehensive school reform…
How to write a surgical clinical research protocol: literature review and practical guide.
Rosenthal, Rachel; Schäfer, Juliane; Briel, Matthias; Bucher, Heiner C; Oertli, Daniel; Dell-Kuster, Salome
2014-02-01
The study protocol is the core document of every clinical research project. Clinical research in studies involving surgical interventions presents some specific challenges, which need to be accounted for and described in the study protocol. The aim of this review is to provide a practical guide for developing a clinical study protocol for surgical interventions with a focus on methodologic issues. On the basis of an in-depth literature search of methodologic literature and on some cardinal published surgical trials and observational studies, the authors provides a 10-step guide for developing a clinical study protocol in surgery. This practical guide outlines key methodologic issues important when planning an ethically and scientifically sound research project involving surgical interventions, with the ultimate goal of providing high-level evidence relevant for health care decision making in surgery. Copyright © 2014 Elsevier Inc. All rights reserved.
Therapeutic aspects of endoscopic ultrasound
NASA Astrophysics Data System (ADS)
Woodward, Timothy A.
1999-06-01
Endoscopic ultrasound (EUS) is a technology that had been used primarily as a passive imaging modality. Recent advances have enabled us to move beyond the use of EUS solely as a staging tool to an interventional device. Current studies suggest that interventional applications of EUS will allow for minimally invasive assessment and therapies in a cost-effective manner. Endoscopic ultrasound with fine needle aspiration (EUS-FNA) has been demonstrated to be a technically feasible, relatively safe method of obtaining cytologic specimens. The clinical utility of EUS- FNA appears to be greatest in the diagnosis and staging of pancreatic cancer and in the nodal staging of gastrointestinal and pulmonary malignancies. In addition, EUS-FNA has demonstrated utility in the sampling pleural and ascitic fluid not generally appreciated or assessable to standard interventions. Interventional applications of EUS include EUS-guided pseudocyst drainage, EUS-guided injection of botulinum toxin in the treatment of achalasia, and EUS- guided celiac plexus neurolysis in the treatment of pancreatic cancer pain. Finally, EUS-guided fine-needle installation is being evaluated, in conjunction with recent bimolecular treatment modalities, as a delivery system in the treatment of certain gastrointestinal tumors.
Patient-specific 3D printing simulation to guide complex coronary intervention.
Oliveira-Santos, Manuel; Oliveira Santos, Eduardo; Marinho, Ana Vera; Leite, Luís; Guardado, Jorge; Matos, Vítor; Pego, Guilherme Mariano; Marques, João Silva
2018-05-07
The field of three-dimensional printing applied to patient-specific simulation is evolving as a tool to enhance intervention results. We report the first case of a fully simulated percutaneous coronary intervention in a three-dimensional patient-specific model to guide treatment. An 85-year-old female presented with symptomatic in-stent restenosis in the ostial circumflex and was scheduled for percutaneous coronary intervention. Considering the complexity of the anatomy, patient setting and intervention technique, we elected to replicate the coronary anatomy using a three-dimensional model. In this way, we simulated the intervention procedure beforehand in the catheterization laboratory using standard materials. The procedure was guided by optical coherence tomography, with pre-dilatation of the lesion, implantation of a single drug-eluting stent in the ostial circumflex and kissing balloon inflation to the left anterior descending artery and circumflex. Procedural steps were replicated in the real patient's treatment, with remarkable parallelism in angiographic outcome and luminal gain at intracoronary imaging. In this proof-of-concept report, we show that patient-specific simulation is feasible to guide the treatment strategy of complex coronary artery disease. It enables the surgical team to plan and practice the procedure beforehand, and possibly predict complications and gain confidence. Copyright © 2018 Sociedade Portuguesa de Cardiologia. Publicado por Elsevier España, S.L.U. All rights reserved.
Ashida, Sato; Heaney, Catherine A; Kmet, Jennifer M; Wilkins, J R
2011-05-01
The North American Guidelines for Children's Agricultural Tasks (NAGCAT) were developed to reduce childhood agricultural injuries by assisting adults in assigning appropriate chores and providing needed supervision and training. To develop an effective intervention to increase adherence to NAGCAT among farm parents, formative research (focus groups and pilot-testing) was conducted. Protection motivation theory (PMT) was used to guide this research and inform intervention development. Focus group results suggested how PMT constructs might be addressed to increase adherence. A home visit intervention, using a standardized presentation in POWERPoint™, was developed to (a) introduce NAGCAT, (b) increase motivation to use NAGCAT and enhance safe work behaviors, and (c) ultimately reduce agricultural work-related injuries among youth. Process evaluation data suggests that the intervention was well received by farm parents. Conducting theory-guided formative research identified motivational barriers and strategies for overcoming these barriers that might not have been otherwise apparent.
Katzmann, Josepha; Hautmann, Christopher; Greimel, Lisa; Imort, Stephanie; Pinior, Julia; Scholz, Kristin; Döpfner, Manfred
2017-05-01
Parent training (PT) delivered as a guided self-help intervention may be a cost- and time-effective intervention in the treatment of children with externalizing disorders. In face-to-face PT, parenting strategies have repeatedly been identified as mediating mechanisms for the decrease of children's problem behavior. Few studies have examined possible mediating effects in guided self-help interventions for parents. The present study aimed to investigate possible mediating variables of a behaviorally oriented guided self-help program for parents of children with externalizing problems compared to a nondirective intervention in a clinical sample. A sample of 110 parents of children with externalizing disorders (80 % boys) were randomized to either a behaviorally oriented or a nondirective guided self-help program. Four putative mediating variables were examined simultaneously in a multiple mediation model using structural equation modelling. The outcomes were child symptoms of ADHD and ODD as well as child externalizing problems, assessed at posttreatment. Analyses showed a significant indirect effect for dysfunctional parental attributions in favor of the group receiving the behavioral program, and significant effects of the behavioral program on positive and negative parenting and parental self-efficacy, compared to the nondirective intervention. Our results indicate that a decrease of dysfunctional parental attributions leads to a decrease of child externalizing problems when parents take part in a behaviorally oriented guided self-help program. However, none of the putative mediating variables could explain the decrease in child externalizing behavior problems in the nondirective group. A change in dysfunctional parental attributions should be considered as a possible mediator in the context of PT.
Musculoskeletal ultrasound for interventional physiatry.
De Muynck, M; Parlevliet, T; De Cock, K; Vanden Bossche, L; Vanderstraeten, G; Özçakar, L
2012-12-01
More and more physiatrists are interested in learning how to use musculoskeletal ultrasonography in their clinical practice. The possibility of high resolution, dynamic, comparative and repeatable imaging makes it an important diagnostic tool for soft tissue pathology. There is also growing interest to use sonography for guiding interventions such as aspirations and infiltrations. In daily practice these are often done blindly or palpation-guided. To improve the accuracy of interventions, fluoroscopy or computed tomography were traditionally used for guidance. Since sonography is non-ionizing, readily available and relatively low cost, it has become the first choice to guide many musculoskeletal interventions. Ultrasound allows real-time imaging of target and needle as well as surrounding vulnerable structures such as vessels and nerves. Many different techniques are proposed in the literature. Interventions under ultrasound guidance have been proven to be more accurate than unguided ones. Further studies are required to prove better clinical results and fewer complications. Infection is the most dreaded complication. This review wants to highlight technical aspects of ultrasound guidance of interventions and give a survey of different interventions that have been introduced, with emphasis on applications in Physical Medicine and Rehabilitation. Results and complications are discussed. Finally training requirements and modalities are presented.
Nam, Chang-Wook; Yoon, Hyuck-Jun; Cho, Yun-Kyeong; Park, Hyoung-Seob; Kim, Hyungseop; Hur, Seung-Ho; Kim, Yoon-Nyun; Chung, In-Sung; Koo, Bon-Kwon; Tahk, Seung-Jae; Fearon, William F; Kim, Kwon-Bae
2010-08-01
This study sought to evaluate the long-term clinical outcomes of a fractional flow reserve (FFR)-guided percutaneous coronary intervention (PCI) strategy compared with intravascular ultrasound (IVUS)-guided PCI for intermediate coronary lesions. Both FFR- and IVUS-guided PCI strategies have been reported to be safe and effective in intermediate coronary lesions. The study included 167 consecutive patients, with intermediate coronary lesions evaluated by FFR or IVUS (FFR-guided, 83 lesions vs. IVUS-guided, 94 lesions). Cutoff value of FFR in FFR-guided PCI was 0.80, whereas that for minimal lumen cross sectional area in IVUS-guided PCI was 4.0 mm(2). The primary outcome was defined as a composite of major adverse cardiac events including death, myocardial infarction, and ischemia-driven target vessel revascularization at 1 year after the index procedure. Baseline percent diameter stenosis and lesion length were similar in both groups (51 +/- 8% and 24 +/- 12 mm in the FFR group vs. 52 +/- 8% and 24 +/- 13 mm in the IVUS group, respectively). However, the IVUS-guided group underwent revascularization therapy significantly more often (91.5% vs. 33.7%, p < 0.001). No significant difference was found in major adverse cardiac event rates between the 2 groups (3.6% in FFR-guided PCI vs. 3.2% in IVUS-guided PCI). Independent predictors for performing intervention were guiding device: FFR versus IVUS (relative risk [RR]: 0.02); left anterior descending coronary artery versus non-left anterior descending coronary artery disease (RR: 5.60); and multi- versus single-vessel disease (RR: 3.28). Both FFR- and IVUS-guided PCI strategy for intermediate coronary artery disease were associated with favorable outcomes. The FFR-guided PCI reduces the need for revascularization of many of these lesions. Copyright (c) 2010 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kapur, T.
At least three major trends in surgical intervention have emerged over the last decade: a move toward more minimally invasive (or non-invasive) approach to the surgical target; the development of high-precision treatment delivery techniques; and the increasing role of multi-modality intraoperative imaging in support of such procedures. This symposium includes invited presentations on recent advances in each of these areas and the emerging role for medical physics research in the development and translation of high-precision interventional techniques. The four speakers are: Keyvan Farahani, “Image-guided focused ultrasound surgery and therapy” Jeffrey H. Siewerdsen, “Advances in image registration and reconstruction for image-guidedmore » neurosurgery” Tina Kapur, “Image-guided surgery and interventions in the advanced multimodality image-guided operating (AMIGO) suite” Raj Shekhar, “Multimodality image-guided interventions: Multimodality for the rest of us” Learning Objectives: Understand the principles and applications of HIFU in surgical ablation. Learn about recent advances in 3D–2D and 3D deformable image registration in support of surgical safety and precision. Learn about recent advances in model-based 3D image reconstruction in application to intraoperative 3D imaging. Understand the multi-modality imaging technologies and clinical applications investigated in the AMIGO suite. Understand the emerging need and techniques to implement multi-modality image guidance in surgical applications such as neurosurgery, orthopaedic surgery, vascular surgery, and interventional radiology. Research supported by the NIH and Siemens Healthcare.; J. Siewerdsen; Grant Support - National Institutes of Health; Grant Support - Siemens Healthcare; Grant Support - Carestream Health; Advisory Board - Carestream Health; Licensing Agreement - Carestream Health; Licensing Agreement - Elekta Oncology.; T. Kapur, P41EB015898; R. Shekhar, Funding: R42CA137886 and R41CA192504 Disclosure and CoI: IGI Technologies, small-business partner on the grants.« less
A hybrid image fusion system for endovascular interventions of peripheral artery disease.
Lalys, Florent; Favre, Ketty; Villena, Alexandre; Durrmann, Vincent; Colleaux, Mathieu; Lucas, Antoine; Kaladji, Adrien
2018-07-01
Interventional endovascular treatment has become the first line of management in the treatment of peripheral artery disease (PAD). However, contrast and radiation exposure continue to limit the feasibility of these procedures. This paper presents a novel hybrid image fusion system for endovascular intervention of PAD. We present two different roadmapping methods from intra- and pre-interventional imaging that can be used either simultaneously or independently, constituting the navigation system. The navigation system is decomposed into several steps that can be entirely integrated within the procedure workflow without modifying it to benefit from the roadmapping. First, a 2D panorama of the entire peripheral artery system is automatically created based on a sequence of stepping fluoroscopic images acquired during the intra-interventional diagnosis phase. During the interventional phase, the live image can be synchronized on the panorama to form the basis of the image fusion system. Two types of augmented information are then integrated. First, an angiography panorama is proposed to avoid contrast media re-injection. Information exploiting the pre-interventional computed tomography angiography (CTA) is also brought to the surgeon by means of semiautomatic 3D/2D registration on the 2D panorama. Each step of the workflow was independently validated. Experiments for both the 2D panorama creation and the synchronization processes showed very accurate results (errors of 1.24 and [Formula: see text] mm, respectively), similarly to the registration on the 3D CTA (errors of [Formula: see text] mm), with minimal user interaction and very low computation time. First results of an on-going clinical study highlighted its major clinical added value on intraoperative parameters. No image fusion system has been proposed yet for endovascular procedures of PAD in lower extremities. More globally, such a navigation system, combining image fusion from different 2D and 3D image sources, is novel in the field of endovascular procedures.
Contrast changes in fluoroscopic imaging systems and statistical variations of these changes
NASA Technical Reports Server (NTRS)
Bailey, N. A.
1973-01-01
Experimental studies have indicated that: (1) The response of digitized fluoroscopic imaging systems is linear systems is linear with contrast over a rather wide range of absorber and cavity thicknesses. (2) Contrast changes associated with the addition of aluminum, iodine containing contrast agents and air of thicknesses 1mm or less can be detected with a 95% confidence level. (3) The standard deviation associated with such determination using clinically available X-ray generators and video disc recording is less than 1 percent. A large flat screen X-ray image intensifier has been constructed and some preliminary results obtained. Sensitivity achieved makes dose reduction a factor often greater than previously reported for a system using a conventional X-ray image intensifier.
Perspectives in ultrasound-guided musculoskeletal interventions
Daftary, Aditya Ravindra; Karnik, Alpana Sudhir
2015-01-01
Ultrasonography (USG) is a safe, easily available, and cost-effective modality, which has the additional advantage of being real time for imaging and image-guided interventions of the musculoskeletal system. Musculoskeletal interventions are gaining popularity in sports and rehabilitation for rapid healing of muscle and tendon injuries in professional athletes, healing of chronic tendinopathies, aspiration of joint effusions, periarticular bursae and ganglia, and perineural injections in acute and chronic pain syndromes. This article aims to provide an overview of the spectrum of musculoskeletal interventions that can be done under USG guidance both for diagnostic and therapeutic purposes. PMID:26288519
Räber, Lorenz; Mintz, Gary S; Koskinas, Konstantinos C; Johnson, Thomas W; Holm, Niels R; Onuma, Yoshinubo; Radu, Maria D; Joner, Michael; Yu, Bo; Jia, Haibo; Menevau, Nicolas; de la Torre Hernandez, Jose M; Escaned, Javier; Hill, Jonathan; Prati, Francesco; Colombo, Antonio; di Mario, Carlo; Regar, Evelyn; Capodanno, Davide; Wijns, William; Byrne, Robert A; Guagliumi, Giulio
2018-05-22
This Consensus Document is the first of two reports summarizing the views of an expert panel organized by the European Association of Percutaneous Cardiovascular Interventions (EAPCI) on the clinical use of intracoronary imaging including intravascular ultrasound (IVUS) and optical coherence tomography (OCT). The first document appraises the role of intracoronary imaging to guide percutaneous coronary interventions (PCIs) in clinical practice. Current evidence regarding the impact of intracoronary imaging guidance on cardiovascular outcomes is summarized, and patients or lesions most likely to derive clinical benefit from an imaging-guided intervention are identified. The relevance of the use of IVUS or OCT prior to PCI for optimizing stent sizing (stent length and diameter) and planning the procedural strategy is discussed. Regarding post-implantation imaging, the consensus group recommends key parameters that characterize an optimal PCI result and provides cut-offs to guide corrective measures and optimize the stenting result. Moreover, routine performance of intracoronary imaging in patients with stent failure (restenosis or stent thrombosis) is recommended. Finally, strengths and limitations of IVUS and OCT for guiding PCI and assessing stent failures and areas that warrant further research are critically discussed.