Sample records for flush water system

  1. 40 CFR 141.804 - Aircraft water system operations and maintenance plan.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... must include the following requirements for procedures for disinfection and flushing of aircraft water system. (i) The air carrier must conduct disinfection and flushing of the aircraft water system in... water procedures; (ii) Sample collection procedures; (iii) Disinfection and flushing procedures; (iv...

  2. 40 CFR 141.804 - Aircraft water system operations and maintenance plan.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS Aircraft Drinking Water Rule... must include the following requirements for procedures for disinfection and flushing of aircraft water system. (i) The air carrier must conduct disinfection and flushing of the aircraft water system in...

  3. 40 CFR 141.803 - Coliform sampling.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... aircraft water system, the sampling frequency must be determined by the disinfection and flushing frequency... disinfection and flushing frequency recommended by the aircraft water system manufacturer, when available. Where the aircraft water system manufacturer does not specify a recommended routine disinfection and...

  4. 40 CFR 141.803 - Coliform sampling.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... the disinfection and flushing frequency recommended by the aircraft water system manufacturer, when... of the aircraft water system is unrestricted. (e) Post disinfection and flushing follow-up sampling....803 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED...

  5. 40 CFR 141.803 - Coliform sampling.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... the disinfection and flushing frequency recommended by the aircraft water system manufacturer, when... of the aircraft water system is unrestricted. (e) Post disinfection and flushing follow-up sampling....803 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED...

  6. Extended testing of compression distillation.

    NASA Technical Reports Server (NTRS)

    Bambenek, R. A.; Nuccio, P. P.

    1972-01-01

    During the past eight years, the NASA Manned Spacecraft Center has supported the development of an integrated water and waste management system which includes the compression distillation process for recovering useable water from urine, urinal flush water, humidity condensate, commode flush water, and concentrated wash water. This paper describes the design of the compression distillation unit, developed for this system, and the testing performed to demonstrate its reliability and performance. In addition, this paper summarizes the work performed on pretreatment and post-treatment processes, to assure the recovery of sterile potable water from urine and treated urinal flush water.

  7. Simulation of the effects of proposed tide gates on circulation, flushing, and water quality in residential canals, Cape Coral Florida

    USGS Publications Warehouse

    Goodwin, Carl R.

    1991-01-01

    Decades of dredging and filling of Florida's low-lying coastal wetlands have produced thousands of miles of residential tidal canals and adjacent waterfront property. Typically, these canals are poorly flushed, and over time, accumulated organic-rich bottom materials, contribute to an increasingly severe degraded water quality. One-dimensional hydrodynamic and constituent-transport models were applied to two dead-end canal systems to determine the effects of canal system interconnection using tide gates on water circulation and constituent flushing. The model simulates existing and possible future circulation and flushing conditions in about 29 miles of the approximately 130 miles of tidally influenced canals in Cape Coral, located on the central west coast of peninsular Florida. Model results indicate that tidal water-level differences between the two canal systems can be converted to kinetic energy, in the form of increased water circulation, but the use of one-way tide gate interconnections. Computations show that construction of from one to four tide gates will cause replacement of a volume of water equivalent to the total volume of canals in both systems in 15 to 9 days, respectively. Because some canals flush faster than others, 47 and 21 percent of the original canal water will remain in both systems 50 days after start of operation of one and four tide gates, respectively. Some of the effects that such increased flushing are expected to have include reduced density stratification and associated dissolved-oxygen depletion in canal bottom waters, increased localized reaeration, and more efficient discharge of stormwater runoff entering the canals.

  8. Water reuse at highway rest areas : evaluation phase.

    DOT National Transportation Integrated Search

    1977-01-01

    The limited availability of water and stringent wastewater effluent standards at rest areas led to the development of a water recycle-reuse system to treat flush water from water closets. Flush fluid for rest area water closets accounts for 95% to 97...

  9. Effects of alkalinity on ammonia removal, carbon dioxide stripping, and system pH in semi-commercial scale water recirculating aquaculture systems operated with moving bed bioreactors

    USDA-ARS?s Scientific Manuscript database

    When operating water recirculating systems (RAS) with high make-up water flushing rates in locations that have low alkalinity in the raw water, such as Norway, knowledge about the required RAS alkalinity concentration is important. Flushing RAS with make-up water containing low alkalinity washes out...

  10. Residential tap water contamination following the Freedom Industries chemical spill: perceptions, water quality, and health impacts.

    PubMed

    Whelton, Andrew J; McMillan, LaKia; Connell, Matt; Kelley, Keven M; Gill, Jeff P; White, Kevin D; Gupta, Rahul; Dey, Rajarshi; Novy, Caroline

    2015-01-20

    During January 2014, an industrial solvent contaminated West Virginia’s Elk River and 15% of the state population’s tap water. A rapid in-home survey and water testing was conducted 2 weeks following the spill to understand resident perceptions, tap water chemical levels, and premise plumbing flushing effectiveness. Water odors were detected in all 10 homes sampled before and after premise plumbing flushing. Survey and medical data indicated flushing caused adverse health impacts. Bench-scale experiments and physiochemical property predictions showed flushing promoted chemical volatilization, and contaminants did not appreciably sorb into cross-linked polyethylene (PEX) pipe. Flushing reduced tap water 4-methylcyclohexanemethanol (4-MCHM) concentrations within some but not all homes. 4-MCHM was detected at unflushed (<10 to 420 μg/L) and flushed plumbing systems (<10 to 96 μg/L) and sometimes concentrations differed among faucets within each home. All waters contained less 4-MCHM than the 1000 μg/L Centers for Disease Control drinking water limit, but one home exceeded the 120 μg/L drinking water limit established by independent toxicologists. Nearly all households refused to resume water use activities after flushing because of water safety concerns. Science based flushing protocols should be developed to expedite recovery, minimize health impacts, and reduce concentrations in homes when future events occur.

  11. How to Dispose of Unused Medicines

    MedlinePlus

    ... trash and recycling facility. Flushing Drugs and the Water Supply Some people wonder if it’s okay to flush ... such as rivers and lakes, and in drinking water supplies. “The main way drug residues enter water systems ...

  12. Real-time control of combined surface water quantity and quality: polder flushing.

    PubMed

    Xu, M; van Overloop, P J; van de Giesen, N C; Stelling, G S

    2010-01-01

    In open water systems, keeping both water depths and water quality at specified values is critical for maintaining a 'healthy' water system. Many systems still require manual operation, at least for water quality management. When applying real-time control, both quantity and quality standards need to be met. In this paper, an artificial polder flushing case is studied. Model Predictive Control (MPC) is developed to control the system. In addition to MPC, a 'forward estimation' procedure is used to acquire water quality predictions for the simplified model used in MPC optimization. In order to illustrate the advantages of MPC, classical control [Proportional-Integral control (PI)] has been developed for comparison in the test case. The results show that both algorithms are able to control the polder flushing process, but MPC is more efficient in functionality and control flexibility.

  13. 46 CFR 194.15-11 - Flushing systems.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ..., AND CONTROL OF EXPLOSIVES AND OTHER HAZARDOUS MATERIALS Chemistry Laboratory and Scientific Laboratory § 194.15-11 Flushing systems. (a) Working spaces in which chemical stores are used shall be equipped with a fresh water supply shower. (b) There shall be a provision for flushing away chemical spills. ...

  14. 46 CFR 194.15-11 - Flushing systems.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ..., AND CONTROL OF EXPLOSIVES AND OTHER HAZARDOUS MATERIALS Chemistry Laboratory and Scientific Laboratory § 194.15-11 Flushing systems. (a) Working spaces in which chemical stores are used shall be equipped with a fresh water supply shower. (b) There shall be a provision for flushing away chemical spills. ...

  15. 46 CFR 194.15-11 - Flushing systems.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ..., AND CONTROL OF EXPLOSIVES AND OTHER HAZARDOUS MATERIALS Chemistry Laboratory and Scientific Laboratory § 194.15-11 Flushing systems. (a) Working spaces in which chemical stores are used shall be equipped with a fresh water supply shower. (b) There shall be a provision for flushing away chemical spills. ...

  16. Impact of Bioreactor Environment and Recovery Method on the Profile of Bacterial Populations from Water Distribution Systems.

    PubMed

    Luo, Xia; Jellison, Kristen L; Huynh, Kevin; Widmer, Giovanni

    2015-01-01

    Multiple rotating annular reactors were seeded with biofilms flushed from water distribution systems to assess (1) whether biofilms grown in bioreactors are representative of biofilms flushed from the water distribution system in terms of bacterial composition and diversity, and (2) whether the biofilm sampling method affects the population profile of the attached bacterial community. Biofilms were grown in bioreactors until thickness stabilized (9 to 11 weeks) and harvested from reactor coupons by sonication, stomaching, bead-beating, and manual scraping. High-throughput sequencing of 16S rRNA amplicons was used to profile bacterial populations from flushed biofilms seeded into bioreactors as well as biofilms recovered from bioreactor coupons by different methods. β diversity between flushed and reactor biofilms was compared to β diversity between (i) biofilms harvested from different reactors and (ii) biofilms harvested by different methods from the same reactor. These analyses showed that average diversity between flushed and bioreactor biofilms was double the diversity between biofilms from different reactors operated in parallel. The diversity between bioreactors was larger than the diversity associated with different biofilm recovery methods. Compared to other experimental variables, the method used to recover biofilms had a negligible impact on the outcome of water biofilm analyses based on 16S amplicon sequencing. Results from this study show that biofilms grown in reactors over 9 to 11 weeks are not representative models of the microbial populations flushed from a distribution system. Furthermore, the bacterial population profile of biofilms grown in replicate reactors from the same flushed water are likely to diverge. However, four common sampling protocols, which differ with respect to disruption of bacterial cells, provide similar information with respect to the 16S rRNA population profile of the biofilm community.

  17. Heavy metal and waste metabolite accumulation and their affect on rainbow trout performance in a replicated water reuse system operated at low or high system flushing rates

    USDA-ARS?s Scientific Manuscript database

    A six-month trial was conducted to compare the effects of high and low make-up water flushing rates on rainbow trout performance and water quality in replicated water reuse aquaculture systems (WRAS). Six identical 9.5 m3 WRAS, containing a single 5.3 m3 tank and operated at a total recirculating fl...

  18. 5. AERATOR VIEW FROM DOWNSTREAM. FLUSH VALVE AT RIGHT OPENS ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    5. AERATOR VIEW FROM DOWNSTREAM. FLUSH VALVE AT RIGHT OPENS TO CLEAR THE SYSTEM ABOVE THE SILT AND DEBRIS AND TO STOP THE FLOW OF WATER INTO THE SYSTEM DOWN LINE. BOX FLUME CONTINUES DOWN LINE TO SEDIMENTATION CHAMBER. - Kalaupapa Water Supply System, Waikolu Valley to Kalaupapa Settlement, Island of Molokai, Kalaupapa, Kalawao County, HI

  19. Risk Assessment of Exposure to Lead in Tap Water among Residents of Seri Kembangan, Selangor State, Malaysia

    PubMed Central

    C. S., Lim; M. S., Shaharuddin; W. Y., Sam

    2013-01-01

    Introduction: A cross sectional study was conducted to estimate risk of exposure to lead via tap water ingestion pathway for the population of Seri Kembangan (SK). Methodology: By using purposive sampling method, 100 respondents who fulfilled the inclusive criteria were selected from different housing areas of SK based on geographical population distribution. Residents with filtration systems installed were excluded from the study. Questionnaires were administered to determine water consumption-related information and demographics. Two water samples (first-flushed and fully-flushed samples) were collected from kitchen tap of each household using HDPE bottles. A total of 200 water samples were collected and lead concentrations were determined using a Graphite Furnace Atomic Absorption Spectrophotometer (GFAAS). Results: Mean lead concentration in first-flushed samples was 3.041± SD 6.967µg/L and 1.064± SD 1.103µg/L for fully-flushed samples. Of the first-flushed samples, four (4) had exceeded the National Drinking Water Quality Standard (NDWQS) lead limit value of 10µg/L while none of the fully-flushed samples had lead concentration exceeded the limit. There was a significant difference between first-flushed samples and fully-flushed samples and flushing had elicited a significant change in lead concentration in the water (Z = -5.880, p<0.05). It was also found that lead concentration in both first-flushed and fully flushed samples was not significantly different across nine (9) areas of Seri Kembangan (p>0.05). Serdang Jaya was found to have the highest lead concentration in first-flushed water (mean= 10.44± SD 17.83µg/L) while Taman Universiti Indah had the highest lead concentration in fully-flushed water (mean=1.45± SD 1.83µg/L). Exposure assessment found that the mean chronic daily intake (CDI) was 0.028± SD 0.034µgday-1kg-1. None of the hazard quotient (HQ) value was found to be greater than 1. Conclusion: The overall quality of water supply in SK was satisfactory because most of the parameters tested in this study were within the range of permissible limit and only a few samples had exceeded the standard values for lead and pH. Non-carcinogenic risk attributed to ingestion of lead in SK tap water was found to be negligible. PMID:23445691

  20. Risk assessment of exposure to lead in tap water among residents of Seri Kembangan, Selangor state, Malaysia.

    PubMed

    Lim, C S; Shaharuddin, M S; Sam, W Y

    2012-11-21

    A cross sectional study was conducted to estimate risk of exposure to lead via tap water ingestion pathway for the population of Seri Kembangan (SK). By using purposive sampling method, 100 respondents who fulfilled the inclusive criteria were selected from different housing areas of SK based on geographical population distribution. Residents with filtration systems installed were excluded from the study. Questionnaires were administered to determine water consumption-related information and demographics. Two water samples (first-flushed and fully-flushed samples) were collected from kitchen tap of each household using HDPE bottles. A total of 200 water samples were collected and lead concentrations were determined using a Graphite Furnace Atomic Absorption Spectrophotometer (GFAAS). Mean lead concentration in first-flushed samples was 3.041± SD 6.967µg/L and 1.064± SD 1.103µg/L for fully-flushed samples. Of the first-flushed samples, four (4) had exceeded the National Drinking Water Quality Standard (NDWQS) lead limit value of 10µg/L while none of the fully-flushed samples had lead concentration exceeded the limit. There was a significant difference between first-flushed samples and fully-flushed samples and flushing had elicited a significant change in lead concentration in the water (Z = -5.880, p<0.05). It was also found that lead concentration in both first-flushed and fully flushed samples was not significantly different across nine (9) areas of Seri Kembangan (p>0.05). Serdang Jaya was found to have the highest lead concentration in first-flushed water (mean= 10.44± SD 17.83µg/L) while Taman Universiti Indah had the highest lead concentration in fully-flushed water (mean=1.45± SD 1.83µg/L). Exposure assessment found that the mean chronic daily intake (CDI) was 0.028± SD 0.034µgday-1kg-1. None of the hazard quotient (HQ) value was found to be greater than 1. The overall quality of water supply in SK was satisfactory because most of the parameters tested in this study were within the range of permissible limit and only a few samples had exceeded the standard values for lead and pH. Non-carcinogenic risk attributed to ingestion of lead in SK tap water was found to be negligible.

  1. Variable-Volume Flushing (V-VF) device for water conservation in toilets

    NASA Technical Reports Server (NTRS)

    Jasper, Louis J., Jr.

    1993-01-01

    Thirty five percent of residential indoor water used is flushed down the toilet. Five out of six flushes are for liquid waste only, which requires only a fraction of the water needed for solid waste. Designers of current low-flush toilets (3.5-gal. flush) and ultra-low-flush toilets (1.5-gal. flush) did not consider the vastly reduced amount of water needed to flush liquid waste versus solid waste. Consequently, these toilets are less practical than desired and can be improved upon for water conservation. This paper describes a variable-volume flushing (V-VF) device that is more reliable than the currently used flushing devices (it will not leak), is simple, more economical, and more water conserving (allowing one to choose the amount of water to use for flushing solid and liquid waste).

  2. Tidal flushing time of marine fish culture zones in Hong Kong

    NASA Astrophysics Data System (ADS)

    Mao, Jing-Qiao; Wong, Ken T. M.; Lee, Joseph H. W.; Choi, K. W.

    2011-12-01

    Accurate determination of flushing time is crucial for maintaining sustainable production in fish culture zones (FCZs), as it represents the physical self-purification capability via tidal exchange with clean water in the outer sea. However, owing to the temporal and spatial complexity of the coastal flushing process, existing methods for determining flushing time may not be generally applicable. In this paper, a systematic method for determining the flushing time in FCZs is presented, in which bathymetry, runoff, tidal range and stratification are properly accounted for. We determine the flushing time via numerical tracer experiments, using robust 3D hydrodynamic and mass transport models. For FCZs located in sheltered and land-locked tidal inlets, the system boundary can be naturally defined at the connection with the open sea. For FCZs located in open waters, hydrodynamic tracking is first used to assess the extent of tidal excursion and thus delimit the initial boundary between clean water and polluted water. This general method is applied to all designated marine FCZs in Hong Kong for both the dry and wet seasons, including 20 sheltered FCZs (in semi-enclosed waters of Tolo Harbour, Mirs Bay, and Port Shelter) and 6 FCZs in open waters. Our results show that flushing time is the longest in inner Port Shelter (about 40 days in dry season), and the shortest for the FCZs in open waters (less than one week in dry season). In addition, the flushing time in dry season is commonly longer than that in wet season: 20%˜40% for most well-sheltered FCZs; 2.6˜4 times for the others. Our results indicate a positive correlation between the flushing time and distance to open boundary, supporting the view that the flushing time of a FCZ is closely related to its location. This study provides a solid basis for mariculture management such as the determination of carrying capacity of FCZs.

  3. Effectiveness of Rack Sanitation Procedures for Elimination of Bacteria from Automatic Watering Manifolds.

    PubMed

    Costello, Terry; Watkins, Linda; Straign, Mike; Bean, William; Toth, Linda; Rehg, Jerold

    1998-03-01

    An important responsibility of animal care programs is to protect research animals from exposure to potentially pathogenic microorganisms. To validate the need for steam sterilization of rodent automatic watering racks, we evaluate the post-sanitation microbial contamination of experimentally inoculated racks and of racks that had been used to house conventional mice. We tested three sanitation protocols: rack-washer sanitation without manifold flush, sanitation that included manifold flush, and sanitation that included manifold flush followed by autoclaving. Rack sanitation, with or without manifold flush, did not reliably eliminate microbial flora from the lixits or manifold drainage water. A total of 43% of all non-autoclaved racks were positive for bacterial contamination after sanitation, and racks that had been used for conventional animal housing were more frequently positive than were experimentally inoculated racks (79% vs 18%). These data indicate that steam sterilization is necessary for eliminating bacteria from automatic watering systems. These observations are particularly important in light of increasing numbers of immune-impaired rodents that may be inadvertently and unnecessarily exposed to microbial pathogens via the automatic watering system.

  4. Reactive solute transport in an asymmetrical fracture-rock matrix system

    NASA Astrophysics Data System (ADS)

    Zhou, Renjie; Zhan, Hongbin

    2018-02-01

    The understanding of reactive solute transport in a single fracture-rock matrix system is the foundation of studying transport behavior in the complex fractured porous media. When transport properties are asymmetrically distributed in the adjacent rock matrixes, reactive solute transport has to be considered as a coupled three-domain problem, which is more complex than the symmetric case with identical transport properties in the adjacent rock matrixes. This study deals with the transport problem in a single fracture-rock matrix system with asymmetrical distribution of transport properties in the rock matrixes. Mathematical models are developed for such a problem under the first-type and the third-type boundary conditions to analyze the spatio-temporal concentration and mass distribution in the fracture and rock matrix with the help of Laplace transform technique and de Hoog numerical inverse Laplace algorithm. The newly acquired solutions are then tested extensively against previous analytical and numerical solutions and are proven to be robust and accurate. Furthermore, a water flushing phase is imposed on the left boundary of system after a certain time. The diffusive mass exchange along the fracture/rock matrixes interfaces and the relative masses stored in each of three domains (fracture, upper rock matrix, and lower rock matrix) after the water flushing provide great insights of transport with asymmetric distribution of transport properties. This study has the following findings: 1) Asymmetric distribution of transport properties imposes greater controls on solute transport in the rock matrixes. However, transport in the fracture is mildly influenced. 2) The mass stored in the fracture responses quickly to water flushing, while the mass stored in the rock matrix is much less sensitive to the water flushing. 3) The diffusive mass exchange during the water flushing phase has similar patterns under symmetric and asymmetric cases. 4) The characteristic distance which refers to the zero diffusion between the fracture and the rock matrix during the water flushing phase is closely associated with dispersive process in the fracture.

  5. Evaluation of RO modules for the SSP ETC/LSS.

    NASA Technical Reports Server (NTRS)

    Jasionowski, W. J.; Bambenek, R. A.

    1973-01-01

    During the past eight years the NASA Manned Spacecraft Center has supported the development of an Integrated Water and Waste Management System for use in the Space Station Prototype (SSP) Environmental Thermal Control/Life-Support System (ETC/LSS). This system includes the reverse osmosis (RO) process for recycling wash water and the compression distillation process for recovering useable water from urine, urinal flush water, humidity condensate, commode flush water and the wash water concentrated by RO. This paper summarizes the experimental work performed during the past four years to select the best commercially available RO module for this system and to also define which surfactants and germicides are most compatible with the selected module.

  6. Dynamics of Biofilm Regrowth in Drinking Water Distribution Systems.

    PubMed

    Douterelo, I; Husband, S; Loza, V; Boxall, J

    2016-07-15

    The majority of biomass within water distribution systems is in the form of attached biofilm. This is known to be central to drinking water quality degradation following treatment, yet little understanding of the dynamics of these highly heterogeneous communities exists. This paper presents original information on such dynamics, with findings demonstrating patterns of material accumulation, seasonality, and influential factors. Rigorous flushing operations repeated over a 1-year period on an operational chlorinated system in the United Kingdom are presented here. Intensive monitoring and sampling were undertaken, including time-series turbidity and detailed microbial analysis using 16S rRNA Illumina MiSeq sequencing. The results show that bacterial dynamics were influenced by differences in the supplied water and by the material remaining attached to the pipe wall following flushing. Turbidity, metals, and phosphate were the main factors correlated with the distribution of bacteria in the samples. Coupled with the lack of inhibition of biofilm development due to residual chlorine, this suggests that limiting inorganic nutrients, rather than organic carbon, might be a viable component in treatment strategies to manage biofilms. The research also showed that repeat flushing exerted beneficial selective pressure, giving another reason for flushing being a viable advantageous biofilm management option. This work advances our understanding of microbiological processes in drinking water distribution systems and helps inform strategies to optimize asset performance. This research provides novel information regarding the dynamics of biofilm formation in real drinking water distribution systems made of different materials. This new knowledge on microbiological process in water supply systems can be used to optimize the performance of the distribution network and to guarantee safe and good-quality drinking water to consumers. Copyright © 2016 Douterelo et al.

  7. Dynamics of Biofilm Regrowth in Drinking Water Distribution Systems

    PubMed Central

    Husband, S.; Loza, V.; Boxall, J.

    2016-01-01

    ABSTRACT The majority of biomass within water distribution systems is in the form of attached biofilm. This is known to be central to drinking water quality degradation following treatment, yet little understanding of the dynamics of these highly heterogeneous communities exists. This paper presents original information on such dynamics, with findings demonstrating patterns of material accumulation, seasonality, and influential factors. Rigorous flushing operations repeated over a 1-year period on an operational chlorinated system in the United Kingdom are presented here. Intensive monitoring and sampling were undertaken, including time-series turbidity and detailed microbial analysis using 16S rRNA Illumina MiSeq sequencing. The results show that bacterial dynamics were influenced by differences in the supplied water and by the material remaining attached to the pipe wall following flushing. Turbidity, metals, and phosphate were the main factors correlated with the distribution of bacteria in the samples. Coupled with the lack of inhibition of biofilm development due to residual chlorine, this suggests that limiting inorganic nutrients, rather than organic carbon, might be a viable component in treatment strategies to manage biofilms. The research also showed that repeat flushing exerted beneficial selective pressure, giving another reason for flushing being a viable advantageous biofilm management option. This work advances our understanding of microbiological processes in drinking water distribution systems and helps inform strategies to optimize asset performance. IMPORTANCE This research provides novel information regarding the dynamics of biofilm formation in real drinking water distribution systems made of different materials. This new knowledge on microbiological process in water supply systems can be used to optimize the performance of the distribution network and to guarantee safe and good-quality drinking water to consumers. PMID:27208119

  8. Simulated formation and flow of microemulsions during surfactant flushing of contaminated soil.

    PubMed

    Ouyan, Ying; Cho, Jong Soo; Mansell, Robert S

    2002-01-01

    Contamination of groundwater resources by non-aqueous phase liquids (NAPLs) has become an issue of increasing environmental concern. This study investigated the formation and flow of microemulsions during surfactant flushing of NAPL-contaminated soil using the finite difference model UTCHEM, which was verified with our laboratory experimental data. Simulation results showed that surfactant flushing of NAPLs (i.e., trichloroethylene and tetrachloroethylene) from the contaminated soils was an emulsion-driven process. Formation of NAPL-in-water microemulsions facilitated the removal of NAPLs from contaminated soils. Changes in soil saturation pressure were used to monitor the mobilization and entrapment of NAPLs during surface flushing process. In general, more NAPLs were clogged in soil pores when the soil saturation pressure increased. Effects of aquifer salinity on the formation and flow of NAPL-in-water microemulsions were significant. This study suggests that the formation and flow of NAPL-in-water microemulsions through aquifer systems are complex physical-chemical phenomena that are critical to effective surfactant flushing of contaminated soils.

  9. The application of improved flow diverter for first flush management.

    PubMed

    Mrowiec, M

    2010-01-01

    The paper presents the investigations on first flush phenomenon based on the total suspended solids (TSS) concentration measurement during selected rainfalls at central part of Czestochowa (Poland) and also the hydrodynamic model of the catchment. The model allows to present the conception of first flush management using an improved flow diverter Septurn. Flow diverters used in the separate sewer systems create a hybrid system called "semi-separate" sewage system, which allows to treat the first flush volume in the waste water treatment plant (WWTP). Proposed construction of the flow diverter makes possible to capture significant part of the pollutant load (TSS) and simultaneously to reduce volume discharges to WWTPs during wet weather.

  10. Dissolution enhancement and mathematical modeling of removal of residual trichloroethene in sands by ozonation during flushing with micro-nano-bubble solution

    NASA Astrophysics Data System (ADS)

    Sung, Menghau; Teng, Chun-Hao; Yang, Tsung-Hsien

    2017-07-01

    Soil flushing using micro-nano-sized bubbles (MNB) in water as the flushing solution was tested in laboratory sand columns for the cleanup of residual trichloroethene (TCE) non-aqueous-phase-liquid (NAPL). Experiments considering flushing with MNB as well as ozone MNB (OZMNB) in water to treat soils contaminated with residual TCE liquid were conducted to examine effects of ozone on dissolution enhancement. The degrees of residual TCE saturation in soils, ranging from 0.44% to 7.6%, were tested. During flushings, aqueous TCE concentrations at the column exit were monitored and TCE masses remained in the columns after flushing were determined. Experimental results between runs with MNB and OZMNB in water revealed that dissolution enhancement was dependent on residual saturation conditions, and the maximum enhancement was around 9%. Governing equations consisting of three coupled partial differential equations (PDEs) were developed to model the system, and high-order finite difference (HOFD) method was employed to solve these PDEs. From mathematical modeling of reactive mass transfer under low residual saturation conditions (0.44% and 1.9%), experimental data were simulated and important controlling mechanisms were identified. It was concluded that a specific parameter pertinent to NAPL-water interfacial area in the Sherwood number had to be modified to satisfactorily describe the dissolution of TCE in the presence of MNB in water.

  11. Full Scale Drinking Water System Decontamination at the Water Security Test Bed.

    PubMed

    Szabo, Jeffrey; Hall, John; Reese, Steve; Goodrich, Jim; Panguluri, Sri; Meiners, Greg; Ernst, Hiba

    2018-03-20

    The EPA's Water Security Test Bed (WSTB) facility is a full-scale representation of a drinking water distribution system. In collaboration with the Idaho National Laboratory (INL), EPA designed the WSTB facility to support full-scale evaluations of water infrastructure decontamination, real-time sensors, mobile water treatment systems, and decontamination of premise plumbing and appliances. The EPA research focused on decontamination of 1) Bacillus globigii (BG) spores, a non-pathogenic surrogate for Bacillus anthracis and 2) Bakken crude oil. Flushing and chlorination effectively removed most BG spores from the bulk water but BG spores still remained on the pipe wall coupons. Soluble oil components of Bakken crude oil were removed by flushing although oil components persisted in the dishwasher and refrigerator water dispenser. Using this full-scale distribution system allows EPA to 1) test contaminants without any human health or ecological risk and 2) inform water systems on effective methodologies responding to possible contamination incidents.

  12. 33 CFR 162.20 - Flushing Bay near La Guardia Airport, Flushing, N.Y.; restricted area.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Flushing Bay near La Guardia Airport, Flushing, N.Y.; restricted area. 162.20 Section 162.20 Navigation and Navigable Waters COAST... NAVIGATION REGULATIONS § 162.20 Flushing Bay near La Guardia Airport, Flushing, N.Y.; restricted area. (a...

  13. Influence of pre- and post-usage flushing frequencies on bacterial water quality of non-touch water fittings.

    PubMed

    Suchomel, Miranda; Diab-Elschahawi, Magda; Kundi, Michael; Assadian, Ojan

    2013-08-30

    Non-touch fittings have been reported to be susceptible for Pseudomonas aeruginosa accumulation. A number of factors may contribute to this, including the frequency of usage, duration of water stagnation, or presence of plastic materials. Programmable non-touch fittings are appearing which allow regular automated post-flushing with cold water to prevent water stagnation. However, the ideal duration of post-flushing is unknown as well as the effect of pre-rinsing with cold water before use. Eight non-touch fittings with brass valve blocks were mounted on a mobile test sink and connected to the same central water pipe source, differing only in presence or absence of water connection pipes, length of connection pipe, frequency of usage, and time intervals for pre- and post-usage water flush. The total bacteria colony-forming unit (cfu) counts were obtained by the spread plate technique. Low frequency of water use in combination with a long stagnating water column resulted in high bacterial cfu counts. Post-usage flushing for 2 seconds did not differ from no flushing. Flushing for 10 seconds with cold water after use or 30 seconds flush before use were both the most effective measures to prevent non-touch fittings from biofilm formation over a period of 20 weeks. Further improvements in water fitting technology could possibly solve the problem of bacterial water contamination in health care settings.

  14. A method for measuring the cleaning effect of flushing disinfectors.

    PubMed Central

    Cederberg, A.; Osterberg, K.

    1980-01-01

    A method is presented with which the mechanical cleaning effect of flushing disinfectors can be estimated independently of the thermal disinfecting effect of the hot flushing water. This makes it possible to specify the demands to be placed on the disinfecting effect of flushing with water of 85 degrees C or more. Bacillus stearothermophilus spores suspended in faeces were used as indicators because of their non-sensitivity to the hot-water temperature. Their elimination by flushing could thus be attributed to the mechanical effect of the water and not to the disinfecting effect of the temperature. A simple bacteriological technique was used, and the elimination factor (EF) was calculated as the ratio of the number of micro-organisms in the contamination before and after flushing. By using flushing water below 50 degrees C for 130 s the EF on a bedpan was about 10(4)-10(6). The effect of flushing with water of the same temperature for only half that time was somewhat weaker and when the temperature was raised to 85 degrees C after half the flushing time the effect was somewhat stronger. It can be presumed that the conventional disinfecting phase with hot (85 degrees C) water for about 45 s in the commonly used flushing units could be substantially shortened and the costs of their use thereby reduced. PMID:6820026

  15. Water system virus detection

    NASA Technical Reports Server (NTRS)

    Fraser, A. S.; Wells, A. F.; Tenoso, H. J. (Inventor)

    1978-01-01

    The performance of a waste water reclamation system is monitored by introducing a non-pathogenic marker virus, bacteriophage F2, into the waste-water prior to treatment and, thereafter, testing the reclaimed water for the presence of the marker virus. A test sample is first concentrated by absorbing any marker virus onto a cellulose acetate filter in the presence of a trivalent cation at low pH and then flushing the filter with a limited quantity of a glycine buffer solution to desorb any marker virus present on the filter. Photo-optical detection of indirect passive immune agglutination by polystyrene beads indicates the performance of the water reclamation system in removing the marker virus. A closed system provides for concentrating any marker virus, initiating and monitoring the passive immune agglutination reaction, and then flushing the system to prepare for another sample.

  16. THE PRESENCE OF ARSENIC IN DRINKING WATER DISTRIBUTION SOLIDS

    EPA Science Inventory

    The objective of this presentation was to determine whether solids found in drinking water distribution systems contain arsenic. Distribution system pipes and solids removed during hydrant flushing were collected from the distribution system of eight water utilities that had mea...

  17. Molybdenum distributions and variability in drinking water from England and Wales.

    PubMed

    Smedley, P L; Cooper, D M; Lapworth, D J

    2014-10-01

    An investigation has been carried out of molybdenum in drinking water from a selection of public supply sources and domestic taps across England and Wales. This was to assess concentrations in relation to the World Health Organization (WHO) health-based value for Mo in drinking water of 70 μg/l and the decision to remove the element from the list of formal guideline values. Samples of treated drinking water from 12 water supply works were monitored up to four times over an 18-month period, and 24 domestic taps were sampled from three of their supply areas. Significant (p < 0.05) differences were apparent in Mo concentration between sources. Highest concentrations were derived from groundwater from a sulphide-mineralised catchment, although concentrations were only 1.5 μg/l. Temporal variability within sites was small, and no seasonal effects (p > 0.05) were detected. Tap water samples collected from three towns (North Wales, the English Midlands, and South East England) supplied uniquely by upland reservoir water, river water, and Chalk groundwater, respectively, also showed a remarkable uniformity in Mo concentrations at each location. Within each, the variability was very small between houses (old and new), between pre-flush and post-flush samples, and between the tap water and respective source water samples. The results indicate that water distribution pipework has a negligible effect on supplied tap water Mo concentrations. The findings contrast with those for Cu, Zn, Ni, Pb, and Cd, which showed significant differences (p < 0.05) in concentrations between pre-flush and post-flush tap water samples. In two pre-flush samples, concentrations of Ni or Pb were above drinking water limits, although in all cases, post-flush waters were compliant. The high concentrations, most likely derived from metal pipework in the domestic distribution system, accumulated during overnight stagnation. The concentrations of Mo observed in British drinking water, in all cases less than 2 μg/l, were more than an order of magnitude below the WHO health-based value and suggest that Mo is unlikely to pose a significant health or water supply problem in England and Wales.

  18. Performance of UV disinfection and the microbial quality of greywater effluent along a reuse system for toilet flushing.

    PubMed

    Friedler, Eran; Gilboa, Yael

    2010-04-01

    This paper examines the microbial quality of treated RBC (Rotating Biological Contactor) and MBR (Membrane Bioreactor) light greywater along a continuous pilot-scale reuse system for toilet flushing, quantifies the efficiency of UV disinfection unit, and evaluates the regrowth potential of selected microorganisms along the system. The UV disinfection unit was found to be very efficient in reducing faecal coliforms and Staphylococcus aureus. On the other hand, its efficiency of inactivation of HPC (Heterotrophic Plate Count) and Pseudomonas aeruginosa was lower. Some regrowth occurred in the reuse system as a result of HPC regrowth which included opportunistic pathogens such as P. aeruginosa. Although the membrane (UF) of the MBR system removed all bacteria from the greywater, bacteria were observed in the reuse system due to "hopping phenomenon." The microbial quality of the disinfected greywater was found to be equal or even better than the microbial quality of "clean" water in toilet bowls flushed with potable water (and used for excretion). Thus, the added health risk associated with reusing the UV-disinfected greywater for toilet flushing (regarding P. aeruginosa and S. aureus), was found to be insignificant. The UV disinfection unit totally removed (100%) the viral indicator (F-RNA phage, host: E. coli F(amp)(+)) injected to the treatment systems simulating transient viral contamination. To conclude, this work contributes to better design of UV disinfection reactors and provides an insight into the long-term behavior of selected microorganisms along on-site greywater reuse systems for toilet flushing. (c) 2010 Elsevier B.V. All rights reserved.

  19. Health implications of PAH release from coated cast iron drinking water distribution systems in The Netherlands.

    PubMed

    Blokker, E J Mirjam; van de Ven, Bianca M; de Jongh, Cindy M; Slaats, P G G Nellie

    2013-05-01

    Coal tar and bitumen have been historically used to coat the insides of cast iron drinking water mains. Polycyclic aromatic hydrocarbons (PAHs) may leach from these coatings into the drinking water and form a potential health risk for humans. We estimated the potential human cancer risk from PAHs in coated cast iron water mains. In a Dutch nationwide study, we collected drinking water samples at 120 locations over a period of 17 days under various operational conditions, such as undisturbed operation, during flushing of pipes, and after a mains repair, and analyzed these samples for PAHs. We then estimated the health risk associated with an exposure scenario over a lifetime. During flushing, PAH levels frequently exceeded drinking water quality standards; after flushing, these levels dropped rapidly. After the repair of cast iron water mains, PAH levels exceeded the drinking water standards for up to 40 days in some locations. The estimated margin of exposure for PAH exposure through drinking water was > 10,000 for all 120 measurement locations, which suggests that PAH exposure through drinking water is of low concern for consumer health. However, factors that differ among water systems, such as the use of chlorination for disinfection, may influence PAH levels in other locations.

  20. Health Implications of PAH Release from Coated Cast Iron Drinking Water Distribution Systems in the Netherlands

    PubMed Central

    van de Ven, Bianca M.; de Jongh, Cindy M.

    2013-01-01

    Background: Coal tar and bitumen have been historically used to coat the insides of cast iron drinking water mains. Polycyclic aromatic hydrocarbons (PAHs) may leach from these coatings into the drinking water and form a potential health risk for humans. Objective: We estimated the potential human cancer risk from PAHs in coated cast iron water mains. Method: In a Dutch nationwide study, we collected drinking water samples at 120 locations over a period of 17 days under various operational conditions, such as undisturbed operation, during flushing of pipes, and after a mains repair, and analyzed these samples for PAHs. We then estimated the health risk associated with an exposure scenario over a lifetime. Results: During flushing, PAH levels frequently exceeded drinking water quality standards; after flushing, these levels dropped rapidly. After the repair of cast iron water mains, PAH levels exceeded the drinking water standards for up to 40 days in some locations. Conclusions: The estimated margin of exposure for PAH exposure through drinking water was > 10,000 for all 120 measurement locations, which suggests that PAH exposure through drinking water is of low concern for consumer health. However, factors that differ among water systems, such as the use of chlorination for disinfection, may influence PAH levels in other locations. PMID:23425894

  1. Decontamination of Drinking Water Infrastructure ...

    EPA Pesticide Factsheets

    Technical Brief This study examines the effectiveness of decontaminating corroded iron and cement-mortar coupons that have been contaminated with spores of Bacillus atrophaeus subsp. globigii (B. globigii), which is often used as a surrogate for pathogenic B. anthracis (anthrax) in disinfection studies. Bacillus spores are persistent on common drinking water material surfaces like corroded iron, requiring physical or chemical methods to decontaminate the infrastructure. In the United States, free chlorine and monochloramine are the primary chemical disinfectants used by the drinking water industry to inactivate microorganisms. Flushing is also a common, easily implemented practice in drinking water distribution systems, although large volumes of contaminated water needing treatment could be generated. Identifying readily available alternative disinfectant formulations for infrastructure decontamination could give water utilities options for responding to specific types of contamination events. In addition to presenting data on flushing alone, which demonstrated the persistence of spores on water infrastructure in the absence of high levels of disinfectants, data on acidified nitrite, chlorine dioxide, free chlorine, monochloramine, ozone, peracetic acid, and followed by flushing are provided.

  2. Extensive Treatment System For Recycling Water For Flushing Fresh Manure And Recovering Nutrients

    NASA Astrophysics Data System (ADS)

    Morand, Philippe; Robin, Paul; Escande, Aurélie; Picot, Bernadette; Pourcher, Anne-Marie; Jiangping, Qiu; Yinsheng, Li; Hamon, Gwenn; Amblard, Charlotte; Luth, Fievet, Sébastien; Oudart, Didier; Le Quéré, Camille Pain; Cluzeau, Daniel; Landrain, Brigitte

    2010-11-01

    From preliminary researches on a pilot scale, a complete demonstration plant was built to treat the effluents of a 30 pregnant sow's piggery. It includes a screen, a vermifilter, a macrophyte lagooning, and a complementary water storage pond; the recycled water is used for flushing, and rainfall is collected to compensate for evapotranspiration. After functioning in 2008 and 2009, it was showed that, during the warm season, the whole plant produced an effluent suitable for flushing, where the concentration decrease was over 70% for the phosphorus and potassium, 95% for the COD and nitrogen, 99.8% for endocrine disruptors (estrogenic activity), and 99.99% for pathogenic micro-organisms. During the cold season, the dilution by the rain water and the treatment effect of the constructed wetlands lead to similar results. Nevertheless, for this season, suitable floating macrophytes that will cover the lagoons remain to be settled.

  3. Analytical scaling relations to evaluate leakage and intrusion in intermittent water supply systems.

    PubMed

    Taylor, David D J; Slocum, Alexander H; Whittle, Andrew J

    2018-01-01

    Intermittent water supplies (IWS) deliver piped water to one billion people; this water is often microbially contaminated. Contaminants that accumulate while IWS are depressurized are flushed into customers' homes when these systems become pressurized. In addition, during the steady-state phase of IWS, contaminants from higher-pressure sources (e.g., sewers) may continue to intrude where pipe pressure is low. To guide the operation and improvement of IWS, this paper proposes an analytic model relating supply pressure, supply duration, leakage, and the volume of intruded, potentially-contaminated, fluids present during flushing and steady-state. The proposed model suggests that increasing the supply duration may improve water quality during the flushing phase, but decrease the subsequent steady-state water quality. As such, regulators and academics should take more care in reporting if water quality samples are taken during flushing or steady-state operational conditions. Pipe leakage increases with increased supply pressure and/or duration. We propose using an equivalent orifice area (EOA) to quantify pipe quality. This provides a more stable metric for regulators and utilities tracking pipe repairs. Finally, we show that the volume of intruded fluid decreases in proportion to reductions in EOA. The proposed relationships are applied to self-reported performance indicators for IWS serving 108 million people described in the IBNET database and in the Benchmarking and Data Book of Water Utilities in India. This application shows that current high-pressure, continuous water supply targets will require extensive EOA reductions. For example, in order to achieve national targets, utilities in India will need to reduce their EOA by a median of at least 90%.

  4. Analytical scaling relations to evaluate leakage and intrusion in intermittent water supply systems

    PubMed Central

    Slocum, Alexander H.; Whittle, Andrew J.

    2018-01-01

    Intermittent water supplies (IWS) deliver piped water to one billion people; this water is often microbially contaminated. Contaminants that accumulate while IWS are depressurized are flushed into customers’ homes when these systems become pressurized. In addition, during the steady-state phase of IWS, contaminants from higher-pressure sources (e.g., sewers) may continue to intrude where pipe pressure is low. To guide the operation and improvement of IWS, this paper proposes an analytic model relating supply pressure, supply duration, leakage, and the volume of intruded, potentially-contaminated, fluids present during flushing and steady-state. The proposed model suggests that increasing the supply duration may improve water quality during the flushing phase, but decrease the subsequent steady-state water quality. As such, regulators and academics should take more care in reporting if water quality samples are taken during flushing or steady-state operational conditions. Pipe leakage increases with increased supply pressure and/or duration. We propose using an equivalent orifice area (EOA) to quantify pipe quality. This provides a more stable metric for regulators and utilities tracking pipe repairs. Finally, we show that the volume of intruded fluid decreases in proportion to reductions in EOA. The proposed relationships are applied to self-reported performance indicators for IWS serving 108 million people described in the IBNET database and in the Benchmarking and Data Book of Water Utilities in India. This application shows that current high-pressure, continuous water supply targets will require extensive EOA reductions. For example, in order to achieve national targets, utilities in India will need to reduce their EOA by a median of at least 90%. PMID:29775462

  5. 40 CFR 141.808 - Audits and inspections.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS Aircraft Drinking Water Rule § 141.808 Audits and..., disinfection and flushing, and general maintenance and self-inspections of aircraft water system. (b) Air... delivery of safe drinking water. ...

  6. Management of Contaminants Stored in Low Permeability Zones - A State of the Science Review

    DTIC Science & Technology

    2013-10-01

    Tank  3:     Permanganate  ...................................................................................................  193...Treatment options explored include steady water flushing (control), enhance water flushing, flushing permanganate , a dechlorinating culture (KB1...Remediation Tank Experiments (OoM: Order of Magnitude. PV: Pore Volume) 2. Enhanced flushing (79 PVs after loading) 3. Permanganate (45 PVs

  7. Potential fresh water saving using greywater in toilet flushing in Syria.

    PubMed

    Mourad, Khaldoon A; Berndtsson, Justyna C; Berndtsson, Ronny

    2011-10-01

    Greywater reuse is becoming an increasingly important factor for potable water saving in many countries. Syria is one of the most water scarce countries in the Middle East. However, greywater reuse is still not common in the country. Regulations and standards for greywater reuse are not available. Recently, however, several stakeholders have started to plan for greywater reuse. The main objective of this paper is to evaluate the potential for potable water saving by using greywater for toilet flushing in a typical Syrian city. The Sweida city in the southern part of Syria was chosen for this purpose. Interviews were made in order to reflect the social acceptance, water consumption, and the percentage of different indoor water uses. An artificial wetland (AW) and a commercial bio filter (CBF) were proposed to treat the greywater, and an economic analysis was performed for the treatment system. Results show that using treated greywater for toilet flushing would save about 35% of the drinking water. The economic analyses of the two proposed systems showed that, in the current water tariff, the payback period for AW and CBF in block systems is 7 and 52 years, respectively. However, this period will reduce to 3 and 21 years, respectively, if full water costs are paid by beneficiaries. Hence, introducing artificial wetlands in order to make greywater use efficient appears to be a viable alternative to save potable water. Copyright © 2011 Elsevier Ltd. All rights reserved.

  8. 30 CFR 75.1101-5 - Installation of foam generator systems.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    .... (b) Foam generator systems shall be equipped with a fire sensor which actuates the system, and each.... (d) Water, power, and chemicals required shall be adequate to maintain water or foam flow for no less than 25 minutes. (e) Water systems shall include strainers with a flush-out connection and a manual...

  9. Processing of combined domestic bath and laundry waste waters for reuse as commode flushing water

    NASA Technical Reports Server (NTRS)

    Hypes, W. D.; Batten, C. E.; Wilkins, J. R.

    1975-01-01

    An experimental investigation of processes and system configurations for reclaiming combined bath and laundry waste waters for reuse as commode flush water was conducted. A 90-min recycle flow was effective in removing particulates and in improving other physical characteristics to the extent that the filtered water was subjectively acceptable for reuse. The addition of a charcoal filter resulted in noticeable improvements in color, turbidity, and suds elimination. Heating and chlorination of the waste waters were investigated for reducing total organism counts and eliminating coliform organisms. A temperature of 335.9 K (145 F) for 30 min and chlorine concentrations of 20 mg/l in the collection tank followed by 10 mg/l in the storage tank were determined to be adequate for this purpose. Water volume relationships and energy-use rates for the waste water reuse systems are also discussed.

  10. Water Reclamation Using a Ceramic Nanofiltration Membrane and Surface Flushing with Ozonated Water

    PubMed Central

    Hoang, Anh T.; Okuda, Tetsuji; Takeuchi, Haruka; Tanaka, Hiroaki; Nghiem, Long D.

    2018-01-01

    A new membrane fouling control technique using ozonated water flushing was evaluated for direct nanofiltration (NF) of secondary wastewater effluent using a ceramic NF membrane. Experiments were conducted at a permeate flux of 44 L/m2h to evaluate the ozonated water flushing technique for fouling mitigation. Surface flushing with clean water did not effectively remove foulants from the NF membrane. In contrast, surface flushing with ozonated water (4 mg/L dissolved ozone) could effectively remove most foulants to restore the membrane permeability. This surface flushing technique using ozonated water was able to limit the progression of fouling to 35% in transmembrane pressure increase over five filtration cycles. Results from this study also heighten the need for further development of ceramic NF membrane to ensure adequate removal of pharmaceuticals and personal care products (PPCPs) for water recycling applications. The ceramic NF membrane used in this study showed approximately 40% TOC rejection, and the rejection of PPCPs was generally low and highly variable. It is expected that the fouling mitigation technique developed here is even more important for ceramic NF membranes with smaller pore size and thus better PPCP rejection. PMID:29671797

  11. Water Reclamation Using a Ceramic Nanofiltration Membrane and Surface Flushing with Ozonated Water.

    PubMed

    Fujioka, Takahiro; Hoang, Anh T; Okuda, Tetsuji; Takeuchi, Haruka; Tanaka, Hiroaki; Nghiem, Long D

    2018-04-19

    A new membrane fouling control technique using ozonated water flushing was evaluated for direct nanofiltration (NF) of secondary wastewater effluent using a ceramic NF membrane. Experiments were conducted at a permeate flux of 44 L/m²h to evaluate the ozonated water flushing technique for fouling mitigation. Surface flushing with clean water did not effectively remove foulants from the NF membrane. In contrast, surface flushing with ozonated water (4 mg/L dissolved ozone) could effectively remove most foulants to restore the membrane permeability. This surface flushing technique using ozonated water was able to limit the progression of fouling to 35% in transmembrane pressure increase over five filtration cycles. Results from this study also heighten the need for further development of ceramic NF membrane to ensure adequate removal of pharmaceuticals and personal care products (PPCPs) for water recycling applications. The ceramic NF membrane used in this study showed approximately 40% TOC rejection, and the rejection of PPCPs was generally low and highly variable. It is expected that the fouling mitigation technique developed here is even more important for ceramic NF membranes with smaller pore size and thus better PPCP rejection.

  12. 40 CFR 141.806 - Reporting requirements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Section 141.806 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS Aircraft Drinking Water Rule § 141.806 Reporting... and routine disinfection and flushing frequency must be included in the aircraft water system...

  13. Multi-purpose rainwater harvesting for water resource recovery and the cooling effect.

    PubMed

    An, Kyoung Jin; Lam, Yun Fat; Hao, Song; Morakinyo, Tobi Eniolu; Furumai, Hiroaki

    2015-12-01

    The potential use of rainwater harvesting in conjunction with miscellaneous water supplies and a rooftop garden with rainwater harvesting facility for temperature reduction have been evaluated in this study for Hong Kong. Various water applications such as toilet flushing and areal climate controls have been systematically considered depending on the availability of seawater toilet flushing using the Geographic Information System (GIS). For water supplies, the district Area Precipitation per Demand Ratio (APDR) has been calculated to quantify the rainwater utilization potential of each administrative district in Hong Kong. Districts with freshwater toilet flushing prove to have higher potential for rainwater harvest and utilization compared to the areas with seawater toilet flushing. Furthermore, the effectiveness of using rainwater harvesting for miscellaneous water supplies in Hong Kong and Tokyo has been analyzed and compared; this revives serious consideration of diurnal and seasonal patterns of rainfall in applying such technology. In terms of the cooling effect, the implementation of a rooftop rainwater harvesting garden has been evaluated using the ENVI-met model. Our results show that a temperature drop of 1.3 °C has been observed due to the rainwater layer in the rain garden. This study provides valuable insight into the applicability of the rainwater harvesting for sustainable water management practice in a highly urbanized city. Copyright © 2015 Elsevier Ltd. All rights reserved.

  14. Town Flush with Benefits from New Water System

    EPA Pesticide Factsheets

    An EPA-funded project to replace the aging and undersized water lines in a Virginia town has transformed the community–providing cost savings, improved water quality and greater public safety, while eliminating leaks that drained half of the town' water.

  15. Water reuse at highway rest areas : follow-up of implementation.

    DOT National Transportation Integrated Search

    1979-01-01

    A water recycle-reuse system researched and developed by the Virginia Highway and Transportation Research Council for treating water closet flush water was constructed at an existing rest area. An existing 10,000 gpd (37,800 lpd) biological wastewate...

  16. 40 CFR 141.808 - Audits and inspections.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ..., disinfection and flushing, and general maintenance and self-inspections of aircraft water system. (b) Air... Section 141.808 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS Aircraft Drinking Water Rule § 141.808 Audits and...

  17. 40 CFR 141.808 - Audits and inspections.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ..., disinfection and flushing, and general maintenance and self-inspections of aircraft water system. (b) Air... Section 141.808 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS Aircraft Drinking Water Rule § 141.808 Audits and...

  18. 40 CFR 141.808 - Audits and inspections.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ..., disinfection and flushing, and general maintenance and self-inspections of aircraft water system. (b) Air... Section 141.808 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS Aircraft Drinking Water Rule § 141.808 Audits and...

  19. 40 CFR 141.808 - Audits and inspections.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ..., disinfection and flushing, and general maintenance and self-inspections of aircraft water system. (b) Air... Section 141.808 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS Aircraft Drinking Water Rule § 141.808 Audits and...

  20. Laboratory Scale Experiments and Numerical Modeling of Cosolvent flushing of NAPL Mixtures in Saturated Porous Media

    NASA Astrophysics Data System (ADS)

    Agaoglu, B.; Scheytt, T. J.; Copty, N. K.

    2011-12-01

    This study examines the mechanistic processes governing multiphase flow of a water-cosolvent-NAPL system in saturated porous media. Laboratory batch and column flushing experiments were conducted to determine the equilibrium properties of pure NAPL and synthetically prepared NAPL mixtures as well as NAPL recovery mechanisms for different water-ethanol contents. The effect of contact time was investigated by considering different steady and intermittent flow velocities. A modified version of multiphase flow simulator (UTCHEM) was used to compare the multiphase model simulations with the column experiment results. The effect of employing different grid geometries (1D, 2D, 3D), heterogeneity and different initial NAPL saturation configurations were also examined in the model. It is shown that the change in velocity affects the mass transfer rate between phases as well as the ultimate NAPL recovery percentage. The experiments with slow flow rate flushing of pure NAPL and the 3D UTCHEM simulations gave similar effluent concentrations and NAPL cumulative recoveries. The results were less consistent for fast non-equilibrium flow conditions. The dissolution process from the NAPL mixture into the water-ethanol flushing solutions was found to be more complex than dissolution expressions incorporated in the numerical model. The dissolution rate of individual organic compounds (namely Toluene and Benzene) from a mixture NAPL into the ethanol-water flushing solution is found not to correlate with their equilibrium solubility values.The implications of this controlled experimental and modeling study on field cosolvent remediation applications are discussed.

  1. Aerosol Generation by Modern Flush Toilets.

    PubMed

    Johnson, David; Lynch, Robert; Marshall, Charles; Mead, Kenneth; Hirst, Deborah

    A microbe-contaminated toilet will produce bioaerosols when flushed. We assessed toilet plume aerosol from high efficiency (HET), pressure-assisted high efficiency (PAT), and flushometer (FOM) toilets with similar bowl water and flush volumes. Total and droplet nuclei "bioaerosols" were assessed. Monodisperse 0.25-1.9- μ m fluorescent microspheres served as microbe surrogates in separate trials in a mockup 5 m 3 water closet (WC). Bowl water seeding was approximately 10 12 particles/mL. Droplet nuclei were sampled onto 0.2- μ m pore size mixed cellulose ester filters beginning 15 min after the flush using open-face cassettes mounted on the WC walls. Pre- and postflush bowl water concentrations were measured. Filter particle counts were analyzed via fluorescent microscopy. Bowl headspace droplet count size distributions were bimodal and similar for all toilet types and flush conditions, with 95% of droplets < 2 μ m diameter and > 99% < 5 μ m. Up to 145,000 droplets were produced per flush, with the high-energy flushometer producing over three times as many as the lower energy PAT and over 12 times as many as the lowest energy HET despite similar flush volumes. The mean numbers of fluorescent droplet nuclei particles aerosolized and remaining airborne also increased with flush energy. Fluorescent droplet nuclei per flush decreased with increasing particle size. These findings suggest two concurrent aerosolization mechanisms-splashing for large droplets and bubble bursting for the fine droplets that form droplet nuclei.

  2. Flushing Time

    EPA Science Inventory

    The flushing time of an estuary is generally defined as the turnover time of fresh water in the estuary, that is, the time required to replace the fresh water contained in the estuary with freshwater inflow. Thus, the flushing time of an estuary is the ratio of the volume of fres...

  3. 40 CFR 141.626 - Operational evaluation levels.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Section 141.626 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS Stage 2 Disinfection Byproducts Requirements § 141... operations, excess storage capacity, distribution system flushing, changes in sources or source water quality...

  4. Laboratory-scale experiments and numerical modeling of cosolvent flushing of multi-component NAPLs in saturated porous media

    NASA Astrophysics Data System (ADS)

    Agaoglu, Berken; Scheytt, Traugott; Copty, Nadim K.

    2012-10-01

    This study examines the mechanistic processes governing multiphase flow of a water-cosolvent-NAPL system in saturated porous media. Laboratory batch and column flushing experiments were conducted to determine the equilibrium properties of pure NAPL and synthetically prepared NAPL mixtures as well as NAPL recovery mechanisms for different water-ethanol contents. The effect of contact time was investigated by considering different steady and intermittent flow velocities. A modified version of multiphase flow simulator (UTCHEM) was used to compare the multiphase model simulations with the column experiment results. The effect of employing different grid geometries (1D, 2D, 3D), heterogeneity and different initial NAPL saturation configurations was also examined in the model. It is shown that the change in velocity affects the mass transfer rate between phases as well as the ultimate NAPL recovery percentage. The experiments with low flow rate flushing of pure NAPL and the 3D UTCHEM simulations gave similar effluent concentrations and NAPL cumulative recoveries. Model simulations over-estimated NAPL recovery for high specific discharges and rate-limited mass transfer, suggesting a constant mass transfer coefficient for the entire flushing experiment may not be valid. When multi-component NAPLs are present, the dissolution rate of individual organic compounds (namely, toluene and benzene) into the ethanol-water flushing solution is found not to correlate with their equilibrium solubility values.

  5. Finding New Water: Development of On-Site Non-Potable Water Reuse Systems

    EPA Science Inventory

    By designing our buildings to collect and treat water generated on-site, can be and reused for flushing our toilets and irrigating our landscaping. Several water sources are generated with-in a building including: rainwater, stormwater, graywater, blackwater and foundation drain...

  6. FIELD TEST OF CYCLODEXTRIN FOR ENHANCED IN-SITU FLUSHING OF MULTIPLE-COMPONENT IMMISCIBLE ORGANIC LIQUID CONTAMINATION: COMPARISON TO WATER FLUSHING

    EPA Science Inventory

    A pilot-scale field experiment was conducted to compare the remediation effectiveness of an enhanced-solubilization technique to that of water flushing for removal of multicomponent nonaqueous-phase organic liquid (NAPL) contaminants form a phreatic aquifer. This innovative remed...

  7. Aerosol Generation by Modern Flush Toilets

    PubMed Central

    Johnson, David; Lynch, Robert; Marshall, Charles; Mead, Kenneth; Hirst, Deborah

    2015-01-01

    A microbe-contaminated toilet will produce bioaerosols when flushed. We assessed toilet plume aerosol from high efficiency (HET), pressure-assisted high efficiency (PAT), and flushometer (FOM) toilets with similar bowl water and flush volumes. Total and droplet nuclei “bioaerosols” were assessed. Monodisperse 0.25–1.9-μm fluorescent microspheres served as microbe surrogates in separate trials in a mockup 5 m3 water closet (WC). Bowl water seeding was approximately 1012 particles/mL. Droplet nuclei were sampled onto 0.2-μm pore size mixed cellulose ester filters beginning 15 min after the flush using open-face cassettes mounted on the WC walls. Pre- and postflush bowl water concentrations were measured. Filter particle counts were analyzed via fluorescent microscopy. Bowl headspace droplet count size distributions were bimodal and similar for all toilet types and flush conditions, with 95% of droplets <2 μm diameter and >99% <5 μm. Up to 145,000 droplets were produced per flush, with the high-energy flushometer producing over three times as many as the lower energy PAT and over 12 times as many as the lowest energy HET despite similar flush volumes. The mean numbers of fluorescent droplet nuclei particles aerosolized and remaining airborne also increased with flush energy. Fluorescent droplet nuclei per flush decreased with increasing particle size. These findings suggest two concurrent aerosolization mechanisms—splashing for large droplets and bubble bursting for the fine droplets that form droplet nuclei. PMID:26635429

  8. 33 CFR 162.20 - Flushing Bay near La Guardia Airport, Flushing, N.Y.; restricted area.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Airport, Flushing, N.Y.; restricted area. 162.20 Section 162.20 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PORTS AND WATERWAYS SAFETY INLAND WATERWAYS NAVIGATION REGULATIONS § 162.20 Flushing Bay near La Guardia Airport, Flushing, N.Y.; restricted area. (a...

  9. 33 CFR 162.20 - Flushing Bay near La Guardia Airport, Flushing, N.Y.; restricted area.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Airport, Flushing, N.Y.; restricted area. 162.20 Section 162.20 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PORTS AND WATERWAYS SAFETY INLAND WATERWAYS NAVIGATION REGULATIONS § 162.20 Flushing Bay near La Guardia Airport, Flushing, N.Y.; restricted area. (a...

  10. Investigating summer flow paths in a Dutch agricultural field using high frequency direct measurements

    NASA Astrophysics Data System (ADS)

    Delsman, J. R.; Waterloo, M. J.; Groen, M. M. A.; Groen, J.; Stuyfzand, P. J.

    2014-11-01

    The search for management strategies to cope with projected water scarcity and water quality deterioration calls for a better understanding of the complex interaction between groundwater and surface water in agricultural catchments. We separately measured flow routes to tile drains and an agricultural ditch in a deep polder in the coastal region of the Netherlands, characterized by exfiltration of brackish regional groundwater flow and intake of diverted river water for irrigation and water quality improvement purposes. We simultaneously measured discharge, electrical conductivity and temperature of these separate flow routes at hourly frequencies, disclosing the complex and time-varying patterns and origins of tile drain and ditch exfiltration. Tile drainage could be characterized as a shallow flow system, showing a non-linear response to groundwater level changes. Tile drainage was fed primarily by meteoric water, but still transported the majority (80%) of groundwater-derived salt to surface water. In contrast, deep brackish groundwater exfiltrating directly in the ditch responded linearly to groundwater level variations and is part of a regional groundwater flow system. We could explain the observed salinity of exfiltrating drain and ditch water from the interaction between the fast-responding pressure distribution in the subsurface that determined groundwater flow paths (wave celerity), and the slow-responding groundwater salinity distribution (water velocity). We found water demand for maintaining water levels and diluting salinity through flushing to greatly exceed the actual sprinkling demand. Counterintuitively, flushing demand was found to be largest during precipitation events, suggesting the possibility of water savings by operational flushing control.

  11. Effect of Intermediate Flush Using Different Devices to Prevent Chemical Smear Layer Formation.

    PubMed

    Silva, Camilla Corrêa; Ferreira, Vivian Maria Durange; De-Deus, Gustavo; Herrera, Daniel Rodrigo; Prado, Maíra do; Silva, Emmanuel João Nogueira Leal da

    2017-01-01

    This study compared the effect of intermediate flush with distilled water delivered by conventional irrigation, EndoVac microcannula or Self-Adjusting File (SAF) system in the prevention of chemical smear layer (CSL) formation. Thirty human premolars were used. Canals were prepared with Reciproc system and 5.25% NaOCl. After chemomechanical preparation, samples were divided in 3 groups (n=10) according to the intermediate irrigation protocol with distilled water using: conventional irrigation, EndoVac microcannula or SAF. A final flush with 2% chlorhexidine solution was used and scanning electron microscopy was performed to assess protocol effectiveness. Two calibrated evaluators attributed scores according the presence or absence of CSL on the surface of the root canal walls at the coronal, middle and apical thirds, as follows: (1) no CSL; (2) small amounts of CSL; (3) moderate CSL; and (4) heavy CSL. Differences between protocols were analyzed with Kruskal-Wallis and Mann-Whitney U tests. Friedman and Wilcoxon signed rank tests were used for comparison between each root canal third. SAF resulted in less formation of CSL when compared with the conventional irrigation and EndoVac microcannula (p<0.05). When root canal thirds were analyzed, conventional irrigation and EndoVac groups showed less CSL formation at coronal and middle thirds in comparison to the apical third (p<0.05). In SAF group, there was no difference among the thirds (p>0.05). It may be concluded that an intermediate flush of distilled water, delivered by the SAF system resulted in a better reduction of CSL formation during chemomechanical preparation.

  12. Decontamination of Bacillus spores adhered to iron and cement-mortar drinking water infrastructure in a model system using disinfectants.

    PubMed

    Szabo, Jeffrey G; Meiners, Greg; Heckman, Lee; Rice, Eugene W; Hall, John

    2017-02-01

    Decontamination of Bacillus spores adhered to common drinking water infrastructure surfaces was evaluated using a variety of disinfectants. Corroded iron and cement-mortar lined iron represented the infrastructure surfaces, and were conditioned in a 23 m long, 15 cm diameter (75 ft long, 6 in diameter) pilot-scale drinking water distribution pipe system. Decontamination was evaluated using increased water velocity (flushing) alone at 0.5 m s -1 (1.7 ft s -1 ), as well as free chlorine (5 and 25 mg L -1 ), monochloramine (25 mg L -1 ), chlorine dioxide (5 and 25 mg L -1 ), ozone (2.0 mg L -1 ), peracetic acid 25 mg L -1 ) and acidified nitrite (0.1 mol L -1 at pH 2 and 3), all followed by flushing at 0.3 m s -1 (1 ft s -1 ). Flushing alone reduced the adhered spores by 0.5 and 2.0 log 10 from iron and cement-mortar, respectively. Log 10 reduction on corroded iron pipe wall coupons ranged from 1.0 to 2.9 at respective chlorine dioxide concentrations of 5 and 25 mg L -1 , although spores were undetectable on the iron surface during disinfection at 25 mg L -1 . Acidified nitrite (pH 2, 0.1 mol L -1 ) yielded no detectable spores on the iron surface during the flushing phase after disinfection. Chlorine dioxide was the best performing disinfectant with >3.0 log 10 removal from cement-mortar at 5 and 25 mg L -1 . The data show that free chlorine, monochloramine, ozone and chlorine dioxide followed by flushing can reduce adhered spores by > 3.0 log 10 on cement-mortar. Published by Elsevier Ltd.

  13. Advantages and limitations for users of double pit pour-flush latrines: a qualitative study in rural Bangladesh.

    PubMed

    Hussain, Faruqe; Clasen, Thomas; Akter, Shahinoor; Bawel, Victoria; Luby, Stephen P; Leontsini, Elli; Unicomb, Leanne; Barua, Milan Kanti; Thomas, Brittany; Winch, Peter J

    2017-05-25

    In rural Bangladesh, India and elsewhere, pour-flush pit latrines are the most common sanitation system. When a single pit latrine becomes full, users must empty it themselves and risk exposure to fresh feces, pay an emptying service to remove pit contents or build a new latrine. Double pit pour-flush latrines may serve as a long-term sanitation option including high water table areas because the pits do not need to be emptied immediately and the excreta decomposes into reusable soil. Double pit pour-flush latrines were implemented in rural Bangladesh for 'hardcore poor' households by a national NGO, BRAC. We conducted interviews, focus groups, and spot checks in two low-income, rural areas of Bangladesh to explore the advantages and limitations of using double pit latrines compared to single pit latrines. The rural households accepted the double pit pour-flush latrine model and considered it feasible to use and maintain. This latrine design increased accessibility of a sanitation facility for these low-income residents and provided privacy, convenience and comfort, compared to open defecation. Although a double pit latrine is more costly and requires more space than a single pit latrine the households perceived this sanitation system to save resources, because households did not need to hire service workers to empty pits or remove decomposed contents themselves. In addition, the excreta decomposition process produced a reusable soil product that some households used in homestead gardening. The durability of the latrine superstructures was a problem, as most of the bamboo-pole superstructure broke after 6-18 months of use. Double pit pour-flush latrines are a long-term improved sanitation option that offers users several important advantages over single pit pour-flush latrines like in rural Bangladesh which can also be used in areas with high water table. Further research can provide an understanding of the comparative health impacts and effectiveness of the model in preventing human excreta from entering the environment.

  14. Laboratory-scale experiments and numerical modeling of cosolvent flushing of multi-component NAPLs in saturated porous media.

    PubMed

    Agaoglu, Berken; Scheytt, Traugott; Copty, Nadim K

    2012-10-01

    This study examines the mechanistic processes governing multiphase flow of a water-cosolvent-NAPL system in saturated porous media. Laboratory batch and column flushing experiments were conducted to determine the equilibrium properties of pure NAPL and synthetically prepared NAPL mixtures as well as NAPL recovery mechanisms for different water-ethanol contents. The effect of contact time was investigated by considering different steady and intermittent flow velocities. A modified version of multiphase flow simulator (UTCHEM) was used to compare the multiphase model simulations with the column experiment results. The effect of employing different grid geometries (1D, 2D, 3D), heterogeneity and different initial NAPL saturation configurations was also examined in the model. It is shown that the change in velocity affects the mass transfer rate between phases as well as the ultimate NAPL recovery percentage. The experiments with low flow rate flushing of pure NAPL and the 3D UTCHEM simulations gave similar effluent concentrations and NAPL cumulative recoveries. Model simulations over-estimated NAPL recovery for high specific discharges and rate-limited mass transfer, suggesting a constant mass transfer coefficient for the entire flushing experiment may not be valid. When multi-component NAPLs are present, the dissolution rate of individual organic compounds (namely, toluene and benzene) into the ethanol-water flushing solution is found not to correlate with their equilibrium solubility values. Copyright © 2012 Elsevier B.V. All rights reserved.

  15. Flow cytometry for immediate follow-up of drinking water networks after maintenance.

    PubMed

    Van Nevel, Sam; Buysschaert, Benjamin; De Roy, Karen; De Gusseme, Bart; Clement, Lieven; Boon, Nico

    2017-03-15

    Drinking water networks need maintenance every once in a while, either planned interventions or emergency repairs. When this involves opening of the water pipes, precautionary measures need to be taken to avoid contamination of the drinking water at all time. Drinking water suppliers routinely apply plating for faecal indicator organisms as quality control in such a situation. However, this takes at least 21 h of waiting time, which can be crucial when dealing with major supply pipes. A combination of flow cytometric (FCM) bacterial cell counts with FCM fingerprinting techniques is proposed in this study as a fast and sensitive additional technique. In three full scale situations, major supply pipes with 400-1050 mm diameter were emptied for maintenance, shock-chlorinated and flushed with large amounts of clean drinking water before taking back in operation. FCM measurements of the discharged flushing water revealed fast lowering and stabilizing bacterial concentrations once flushing is initiated. Immediate comparison with clean reference drinking water used for flushing was done, and the moment when both waters had similar bacterial concentrations was considered as the endpoint of the necessary flushing works. This was usually after 2-4 h of flushing. FCM fingerprinting, based on both bacteria and FCM background, was used as additional method to verify how similar flushing and reference samples were and yielded similar results. The FCM approved samples were several hours later approved as well by the drinking water supplier after plating and incubation for total Coliforms and Enterococci. These were used as decisive control to set the pipes back in operation. FCM proved to be a more conservative test than plating, yet it yielded immediate results. Application of these FCM methods can therefore avoid long unnecessary waiting times and large drinking water losses. Copyright © 2016 Elsevier Ltd. All rights reserved.

  16. Economic and environmental analysis of standard, high efficiency, rainwater flushed, and composting toilets.

    PubMed

    Anand, C; Apul, D S

    2011-03-01

    The current sanitation technology in developed countries is based on diluting human excreta with large volumes of centrally provided potable water. This approach is a poor use of water resources and is also inefficient, expensive, and energy intensive. The goal of this study was to compare the standard sanitation technology (Scenario 1) with alternative technologies that require less or no potable water use in toilets. The alternative technologies considered were high efficiency toilets flushed with potable water (Scenario 2), standard toilets flushed with rainwater (Scenario 3), high efficiency toilets flushed with rainwater (Scenario 4), and composting toilets (Scenario 5). Cost, energy, and carbon implications of these five design scenarios were studied using two existing University of Toledo buildings. The results showed that alternative systems modeled in Scenarios 2, 4, and 5 were viable options both from an investment and an environmental performance perspective. High efficiency fixtures that use potable water (Scenario 2) is often the most preferred method in high efficiency buildings due to reduced water use and associated reductions in annual water and wastewater costs. However, the cost, energy, and CO(2)EE analyses all showed that Scenarios 4 and 5 were preferable over Scenario 2. Cost payback periods of scenarios 2, 4 and 5 were less than 10 years; in the future, increase in water and wastewater services would further decrease the payback periods. The centralized water and wastewater services have high carbon footprints; therefore if carbon footprint reduction is a primary goal of a building complex, alternative technologies that require less potable water and generate less wastewater can largely reduce the carbon footprint. High efficiency fixtures flushed with rainwater (Scenario 4) and composting toilets (Scenario 5) required considerably less energy than direct energy demands of buildings. However, the annual carbon footprint of these technologies was comparable to the annual carbon footprint from space heating. Similarly, the carbon savings that could be achieved from Scenario 4 or 5 were comparable to a recycling program that can be implemented in buildings. Copyright © 2010 Elsevier Ltd. All rights reserved.

  17. Assessing efficiency and economic viability of rainwater harvesting systems for meeting non-potable water demands in four climatic zones of China

    NASA Astrophysics Data System (ADS)

    Zhang, S.; Jing, X.

    2017-12-01

    Rainwater harvesting is now increasingly used to manage urban flood and alleviate water scarcity crisis. In this study, a computational tool based on water balance equation is developed to assess stormwater capture and water saving efficiency and economic viability of rainwater harvesting systems (RHS) in eight cities across four climatic zones of China. It requires daily rainfall, contributing area, runoff losses, first flush volume, storage capacity, daily water demand and economic parameters as inputs. Three non-potable water demand scenarios (i.e., toilet flushing, lawn irrigation, and combination of them) are considered. The water demand for lawn irrigation is estimated using the Cropwat 8.0 and Climwat 2.0. Results indicate that higher water saving efficiency and water supply time reliability can be achieved for RHS with larger storage capacities, for lower water demand scenarios and located in more humid regions, while higher stormwater capture efficiency is associated with larger storage capacity, higher water demand scenarios and less rainfall. For instance, a 40 m3 RHS in Shanghai (humid climate) for lawn irrigation can capture 17% of stormwater, while its water saving efficiency and time reliability can reach 96 % and 98%, respectively. The water saving efficiency and time reliability of a 20 m3 RHS in Xining (semi-arid climate) for toilet flushing are 19% and 16%, respectively, but it can capture 63% of stormwater. With the current values of economic parameters, economic viability of RHS can be achieved in humid and semi-humid regions for reasonably designed RHS; however, it is not financially viable to install RHS in arid regions as the benefit-cost ratio is much smaller than 1.0.

  18. Lead (Pb) contamination of self-supply groundwater systems in coastal Madagascar and predictions of blood lead levels in exposed children.

    PubMed

    Akers, D Brad; MacCarthy, Michael F; Cunningham, Jeffrey A; Annis, Jonathan; Mihelcic, James R

    2015-03-03

    Thousands of households in coastal Madagascar rely on locally manufactured pitcher-pump systems to provide water for drinking, cooking, and household use. These pumps typically include components made from lead (Pb). In this study, concentrations of Pb in water were monitored at 18 household pitcher pumps in the city of Tamatave over three sampling campaigns. Concentrations of Pb frequently exceeded the World Health Organization's provisional guideline for drinking water of 10 μg/L. Under first-draw conditions (i.e., after a pump had been inactive for 1 h), 67% of samples analyzed were in excess of 10 μg/L Pb, with a median concentration of 13 μg/L. However, flushing the pump systems before collecting water resulted in a statistically significant (p < 0.0001) decrease in Pb concentrations: 35% of samples collected after flushing exceeded 10 μg/L, with a median concentration of 9 μg/L. Based on measured Pb concentrations, a biokinetic model estimates that anywhere from 15% to 70% of children living in households with pitcher pumps may be at risk for elevated blood lead levels (>5 μg/dL). Measured Pb concentrations in water were not correlated at statistically significant levels with pump-system age, well depth, system manufacturer, or season of sample collection; only the contact time (i.e., flushed or first-draw condition) was observed to correlate significantly with Pb concentrations. In two of the 18 systems, Pb valve weights were replaced with iron, which decreased the observed Pb concentrations in the water by 57-89% in one pump and by 89-96% in the other. Both systems produced samples exclusively below 10 μg/L after substitution. Therefore, relatively straightforward operational changes on the part of the pump-system manufacturers and pump users might reduce Pb exposure, thereby helping to ensure the continued sustainability of pitcher pumps in Madagascar.

  19. 19. PIPELINE INTERSECTION AT THE MOUTH OF WAIKOLU VALLEY ON ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    19. PIPELINE INTERSECTION AT THE MOUTH OF WAIKOLU VALLEY ON THE BEACH. VALVE AT RIGHT (WITH WRENCH NEARBY) OPENS TO FLUSH VALLEY SYSTEM OUT. VALVE AT LEFT CLOSES TO KEEP WATER FROM ENTERING SYSTEM ALONG THE PALI DURING REPAIRS. - Kalaupapa Water Supply System, Waikolu Valley to Kalaupapa Settlement, Island of Molokai, Kalaupapa, Kalawao County, HI

  20. Single house on-site grey water treatment using a submerged membrane bioreactor for toilet flushing.

    PubMed

    Fountoulakis, M S; Markakis, N; Petousi, I; Manios, T

    2016-05-01

    Wastewater recycling has been and continues to be practiced all over the world for a variety of reasons including: increasing water availability, combating water shortages and drought, and supporting environmental and public health protection. Nowadays, one of the most interesting issues for wastewater recycling is the on-site treatment and reuse of grey water. During this study the efficiency of a compact Submerged Membrane Bioreactor (SMBR) system to treat real grey water in a single house in Crete, Greece, was examined. In the study, grey water was collected from a bathtub, shower and washing machine containing significant amounts of organic matter and pathogens. Chemical oxygen demand (COD) removal in the system was approximately 87%. Total suspended solids (TSS) were reduced from 95mgL(-1) in the influent to 8mgL(-1) in the effluent. The efficiency of the system to reduce anionic surfactants was about 80%. Fecal and total coliforms decreased significantly using the SMBR system due to rejection, by the membrane, used in the study. Overall, the SMBR treatment produces average effluent values that would satisfy international guidelines for indoor reuse applications such as toilet flushing. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. Investigation of Aerodynamic and Icing Characteristics of a Flush Alternate Inlet Induction System Air Scoop

    NASA Technical Reports Server (NTRS)

    Lewis, James P.

    1953-01-01

    An investigation has been made in the NACA Lewis icing research tunnel to determine the aerodynamic and icing characteristics of a full-scale induction-system air-scoop assembly incorporating a flush alternate inlet. The flush inlet was located immediately downstream of the offset ram inlet and included a 180 deg reversal and a 90 deg elbow in the ducting between inlet and carburetor top deck. The model also had a preheat-air inlet. The investigation was made over a range of mass-air- flow ratios of 0 to 0.8, angles of attack of 0 and 4 deg airspeeds of 150 to 270 miles per hour, air temperatures of 0 and 25 F various liquid-water contents, and droplet sizes. The ram inlet gave good pressure recovery in both clear air and icing but rapid blockage of the top-deck screen occurred during icing. The flush alternate inlet had poor pressure recovery in both clear air and icing. The greatest decreases in the alternate-inlet pressure recovery were obtained at icing conditions of low air temperature and high liquid-water content. No serious screen icing was observed with the alternate inlet. Pressure and temperature distributions on the carburetor top deck were determined using the preheat-air supply with the preheat- and alternate-inlet doors in various positions. No screen icing occurred when the preheat-air system was operated in combination with alternate-inlet air flow.

  2. Developing the Water Supply System for Travel to Mars

    NASA Technical Reports Server (NTRS)

    Jones, Harry W.; Fisher, John W.; Delzeit, Lance D.; Flynn, Michael T.; Kliss, Mark H.

    2016-01-01

    What water supply method should be used on a trip to Mars? Two alternate approaches are using fuel cell and stored water, as was done for short missions such as Apollo and the Space Shuttle, or recycling most of the water, as on long missions including the International Space Station (ISS). Stored water is inexpensive for brief missions but its launch mass and cost become very large for long missions. Recycling systems have much lower total mass and cost for long missions, but they have high development cost and are more expensive to operate than storage. A Mars transit mission would have an intermediate duration of about 450 days out and back. Since Mars transit is about ten times longer than a brief mission but probably less than one-tenth as long as ISS, it is not clear if stored or recycled water would be best. Recycling system design is complicated because water is used for different purposes, drinking, food preparation, washing, and flushing the urinal, and because wastewater has different forms, humidity condensate, dirty wash water, and urine and flush water. The uses have different requirements and the wastewater resources have different contaminants and processing requirements. The most cost-effective water supply system may recycle some wastewater sources and also provide safety reserve water from storage. Different water supply technologies are compared using mass, cost, reliability, and other factors.

  3. Legionnaire's disease: a nosocomial outbreak in Turkey.

    PubMed

    Ozerol, I H; Bayraktar, M; Cizmeci, Z; Durmaz, R; Akbas, E; Yildirim, Z; Yologlu, S

    2006-01-01

    Six nosocomial cases of Legionella pneumophila occurred over a two-week period, with one further case being diagnosed retrospectively after 30 days. Strains isolated from the hospital water system were clonally related to a single sputum isolate. A sero-epidemiological investigation into legionella exposure amongst staff and inpatients was undertaken at the eight-year-old Inonu University Medical Centre in Turkey, which has 600 beds and central air conditioning. There is no disinfection programme for the hospital water system. A total of 500 serum samples (400 hospital staff and 100 inpatients) were screened for antibody to L. pneumophila by enzyme-linked immunosorbent assay (ELISA). Seroreactive cases were confirmed by a four-fold antibody rise in ELISA, a high indirect immunofluorescent assay (IFA) antibody titre or a positive urinary antigen test. ELISA showed that 24 (6%) of the 400 hospital staff and seven (7%) of the 100 inpatients had antibody titres higher than the cut-off value. ELISA-seroreactive cases were followed for two to four weeks. Of these subjects, seven (three patients and four staff) showed a four-fold rise in antibody titre by ELISA, six (three patients and three staff) had a high IFA titre, three patients with pneumonia had a positive urinary antigen test, and one of these patients also had a positive sputum culture. In addition, 22 water distribution systems were screened for the presence of L. pneumophila by culture. L. pneumophila was isolated from 15 sites. Pulsed-field gel electrophoresis typing indicated that all strains isolated from water systems were identical and clonally related to the strain isolated from sputum. Superheating and flushing of water systems were undertaken with legionella being re-isolated from four sites. Repeated superheating and flushing eliminated legionella completely. This study demonstrated that rapid detection of L. pneumophila and adequate superheating and flushing of water systems are effective for elimination and reduction of spread of this organism.

  4. Impact of Water Management on Efficacy of Insecticide Seed Treatments Against Rice Water Weevil (Coleoptera: Curculionidae) in Mississippi Rice

    PubMed Central

    Adams, A.; Gore, J.; Musser, F.; Cook, D.; Catchot, A.; Walker, T.; Awuni, G. A.

    2015-01-01

    Two experiments were conducted at the Delta Research and Extension Center in Stoneville, MS, during 2011 and 2012 to determine the impact of water management practices on the efficacy of insecticidal seed treatments targeting rice water weevil, Lissorhoptrus oryzophilus Kuschel. Larval densities and yield were compared for plots treated with labeled rates of thiamethoxam, chlorantraniliprole, and clothianidin and an untreated control. In the first experiment, plots were subjected to flood initiated at 6 and 8 wk after planting. Seed treatments significantly reduced larval densities with the 8-wk flood timing, but not the 6-wk flood timing. Overall, the treated plots yielded higher than the control plots. In the second experiment, the impact of multiple flushes on the efficacy of insecticidal seed treatments was evaluated. Plots were subjected to zero, one, or two flushes with water. All seed treatments reduced larval densities compared with the untreated control. Significantly fewer larvae were observed in plots that received one or two flushes compared with plots that did not receive a flush. All seed treatments resulted in higher yields compared to the untreated control in the zero and one flush treatments. When two flushes were applied, yield from the thiamethoxam and clothianidin treated plots was not significantly different from those of the control plots, while the chlorantraniliprole treated plots yielded significantly higher than the control. These data suggest that time from planting to flood did not impact the efficacy of seed treatments, but multiple flushes reduced the efficacy of thiamethoxam and clothianidin. PMID:26470232

  5. Electrochemical disinfection of repeatedly recycled blackwater in a free-standing, additive-free toilet.

    PubMed

    Hawkins, Brian T; Sellgren, Katelyn L; Klem, Ethan J D; Piascik, Jeffrey R; Stoner, Brian R

    2017-11-01

    Decentralized, energy-efficient waste water treatment technologies enabling water reuse are needed to sustainably address sanitation needs in water- and energy-scarce environments. Here, we describe the effects of repeated recycling of disinfected blackwater (as flush liquid) on the energy required to achieve full disinfection with an electrochemical process in a prototype toilet system. The recycled liquid rapidly reached a steady state with total solids reliably ranging between 0.50 and 0.65% and conductivity between 20 and 23 mS/cm through many flush cycles over 15 weeks. The increase in accumulated solids was associated with increased energy demand and wide variation in the free chlorine contact time required to achieve complete disinfection. Further studies on the system at steady state revealed that running at higher voltage modestly improves energy efficiency, and established running parameters that reliably achieve disinfection at fixed run times. These results will guide prototype testing in the field.

  6. Laboratory investigations of the effects of geologic heterogeneity on groundwater salinization and flush-out times from a tsunami-like event.

    PubMed

    Vithanage, M; Engesgaard, P; Jensen, K H; Illangasekare, T H; Obeysekera, J

    2012-08-01

    This intermediate scale laboratory experimental study was designed to improve the conceptual understanding of aquifer flushing time associated with diffuse saltwater contamination of coastal aquifers due to a tsunami-like event. The motivation comes from field observations made after the tsunami in December, 2004 in South Asia. The focus is on the role and effects of heterogeneity on flushing effectiveness. A scheme that combines experimentation in a 4.8m long laboratory tank and numerical modeling was used. To demonstrate the effects of geologic heterogeneity, plume migration and flushing times were analyzed in both homogeneous and layered media and under different boundary conditions (ambient flow, saltwater infiltration rate, freshwater recharge). Saltwater and freshwater infiltrations imitate the results of the groundwater salinization from the tsunami and freshening from the monsoon rainfall. The saltwater plume behavior was monitored both through visual observations (digital photography) of the dyed salt water and using measurements taken from several electrical conductivity sensors installed through the tank walls. The variable-density, three dimensional code HST3D was used to simulate the tank experiments and understand the fate and movement of the saltwater plume under field conditions. The results from the tank experiments and modeling demonstrated that macro-scale heterogeneity significantly influenced the migration patterns and flushing times of diffuse saltwater contamination. Ambient flow had a direct influence on total flush-out time, and heterogeneity impacted flush-out times for the top part of the tank and total flush-out times. The presence of a continuous low-permeability layer caused a 40% increase in complete flush-out time due to the slower flow of salt water in the low-permeability layer. When a relatively small opening was introduced in the low-permeability layer, salt water migrated quickly into a higher-permeable layer below causing a reduction in flush-out time. Freshwater recharge caused an early dilution of salt water in the top part of the tank in the case of a layered media, but also pushed the saltwater plume into the low-permeability layer which led to increased total flush-out times. Copyright © 2012 Elsevier B.V. All rights reserved.

  7. Stormwater run-off from an industrial log yard: characterization, contaminant correlation and first-flush phenomenon.

    PubMed

    Kaczala, Fabio; Marques, Marcia; Vinrot, Eva; Hogland, William

    2012-01-01

    The stormwater run-off generated in an industrial log yard during eight run-off events was studied with the main focus on the transport of toxic metals. Associations between water quality constituents and potential surrogates were evaluated by correlation analysis. The first-flush phenomenon was verified by normalized M(V) curves. The results have shown that, whereas some metals such as Zn, Ba, Cd, As and Fe were always detected in these waters, others (Cr, Pb, Cu, Ni, V, Co) were not. Large variations in the water constituents' concentrations were observed, with Fe, Pb and V being the most variable ones. Concentrations of Zn and Cu in the run-off waters exceeded the values established by the Swedish environmental authorities in 100% and 97% of samples, respectively. The correlation analyses indicated TSS as a potential surrogate of Pb, V, Co, Ni, As, Ba, Cr and COD (0.949 > R > 0.808), making it reasonable to state that a treatment system with focus on TSS removal would also reduce toxic metals from these waters. The first-flush phenomenon was evident for most of the constituents. Significant differences (p < 0.05) in the first-flush magnitude of different run-off events were observed confirming that hydro-meteorological variables such as dry period, precipitation duration and average intensity play important roles. Metal loads originating from the log yard were mainly composed ofZn, Cu and Ba. Knowledge of the physicochemical characteristics, discharge dynamics and the storm variables involved in the process is a crucial step for the proposal and implementation of a stormwater management programme.

  8. Space Shuttle reaction control system thruster metal nitrate removal and characterization

    NASA Technical Reports Server (NTRS)

    Saulsberry, R. L.; Mccartney, P. A.

    1993-01-01

    The Space Shuttle hypergolic primary reaction control system (PRCS) thrusters continue to fail-leak or fail-off at a rate of approximately 1.5 per flight, attributed primarily to metal nitrate formation in the nitrogen tetroxide (N2O4) pilot operated valves (POV's). The failures have continued despite ground support equipment (GSE) and subsystem operational improvements. As a result, the Johnson Space Center (JSC) White Sands Test Facility (WSTF) performed a study to characterize the contamination in the N204 valves. This study prompted the development and implementation of a highly successful flushing technique using deionized (DI) water and gaseous nitrogen (GN2) to remove the contamination while minimizing Teflon seat damage. Following flushing a comprehensive acceptance test is performed before the thruster is deemed recovered. Between the time WSTF was certified to process flight thrusters (March 1992) and September 1993, a 68 percent thruster recovery rate was achieved. The contamination flushed from these thrusters was analyzed and has provided insight into the corrosion process, which is reported in this publication. Additionally, the long-term performance of 24 flushed thrusters installed in the WSTF Fleet Leader Shuttle reaction control subsystem (RCS) test articles is being assessed. WSTF continues to flush flight and test article thrusters and compile data to investigate metal nitrate formation characteristics in leaking and nonleaking valves.

  9. If I do not have enough water, then how could I bring additional water for toilet cleaning?! Addressing water scarcity to promote hygienic use of shared toilets in Dhaka, Bangladesh.

    PubMed

    Saxton, Ronald E; Yeasmin, Farzana; Alam, Mahbub-Ul; Al-Masud, Abdullah; Dutta, Notan Chandra; Yeasmin, Dalia; Luby, Stephen P; Unicomb, Leanne; Winch, Peter J

    2017-09-01

    Provision of toilets is necessary but not sufficient to impact health as poor maintenance may impair toilet function and discourage their consistent use. Water in urban slums is both scarce and a prerequisite for toilet maintenance behaviours. We describe the development of behaviour change communications and selection of low-cost water storage hardware to facilitate adequate flushing among users of shared toilets. We conducted nine focus group discussions and six ranking exercises with adult users of shared toilets (50 females, 35 males), then designed and implemented three pilot interventions to facilitate regular flushing and improve hygienic conditions of shared toilets. We conducted follow-up assessments 1 and 2 months post-pilot including nine in-depth interviews and three focus group discussions with adult residents (23 females, 15 males) and three landlords in the pilot communities. Periodic water scarcity was common in the study communities. Residents felt embarrassed to carry water for flushing. Reserving water adjacent to the shared toilet enabled slum residents to flush regularly. Signs depicting rules for toilet use empowered residents and landlords to communicate these expectations for flushing to transient tenants. Residents in the pilot reported improvements in cleanliness and reduced odour inside toilet cubicles. Our pilot demonstrates the potential efficacy of low-cost water storage and behaviour change communications to improve maintenance of and user satisfaction with shared toilets in urban slum settings. © 2017 John Wiley & Sons Ltd.

  10. ENGINEERING BULLETIN: IN SITU SOIL FLUSHING

    EPA Science Inventory

    In situ soil flushing is the extraction of contaminants from the soil with water or other suitable aqueous solutions. Soil flushing is accomplished by passing the extraction fluid through in-place soils using an injection or infiltration process. Extraction fluids must be recover...

  11. Comparative human health risk analysis of coastal community water and waste service options.

    PubMed

    Schoen, Mary E; Xue, Xiaobo; Hawkins, Troy R; Ashbolt, Nicholas J

    2014-08-19

    As a pilot approach to describe adverse human health effects from alternative decentralized community water systems compared to conventional centralized services (business-as-usual [BAU]), selected chemical and microbial hazards were assessed using disability adjusted life years (DALYs) as the common metric. The alternatives included: (1) composting toilets with septic system, (2) urine-diverting toilets with septic system, (3) low flush toilets with blackwater pressure sewer and on-site greywater collection and treatment for nonpotable reuse, and (4) alternative 3 with on-site rainwater treatment and use. Various pathogens (viral, bacterial, and protozoan) and chemicals (disinfection byproducts [DBPs]) were used as reference hazards. The exposure pathways for BAU included accidental ingestion of contaminated recreational water, ingestion of cross-connected sewage to drinking water, and shower exposures to DBPs. The alternative systems included ingestion of treated greywater from garden irrigation, toilet flushing, and crop consumption; and ingestion of treated rainwater while showering. The pathways with the highest health impact included the ingestion of cross-connected drinking water and ingestion of recreational water contaminated by septic seepage. These were also among the most uncertain when characterizing input parameters, particularly the scale of the cross-connection event, and the removal of pathogens during groundwater transport of septic seepage. A comparison of the health burdens indicated potential health benefits by switching from BAU to decentralized water and wastewater systems.

  12. 46 CFR 194.20-11 - Flushing systems.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 7 2014-10-01 2014-10-01 false Flushing systems. 194.20-11 Section 194.20-11 Shipping... Flushing systems. (a) Provision shall be made for flushing away chemical spills. (b) If a drainage system is installed, it shall be separate from any other drainage system. ...

  13. 46 CFR 194.20-11 - Flushing systems.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 7 2013-10-01 2013-10-01 false Flushing systems. 194.20-11 Section 194.20-11 Shipping... Flushing systems. (a) Provision shall be made for flushing away chemical spills. (b) If a drainage system is installed, it shall be separate from any other drainage system. ...

  14. 46 CFR 194.20-11 - Flushing systems.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Flushing systems. 194.20-11 Section 194.20-11 Shipping... Flushing systems. (a) Provision shall be made for flushing away chemical spills. (b) If a drainage system is installed, it shall be separate from any other drainage system. ...

  15. Water Efficient Installations - A New Army Guidance Document

    DTIC Science & Technology

    2010-06-01

    Toilets 1.28 gpf or less, 50 manuf., 500+ models Required in CA Dual flush options also available WaterSense program provides certification and...lose 8760 to 219,000 gal/year Broken flush valve on toilet can lose 40 gal/hour US Army Corps of Engineers® Engineer Research and Development Center...Engineer Research and Development Center Toilets and Urinals ULFTs Ultra-Low Flush Toilet , also called low flow 1.28 gpf to 1.6 gpf HETs High Efficiency

  16. Wake Island Supplemental Environmental Assessment

    DTIC Science & Technology

    2007-02-01

    operations, the oxidizer transfer system would be flushed with water . This operation is expected to yield approximately 5 grams (0.2 ounces) of nitric...Defense System (BMDS) to provide a defensive capability for the U.S., its deployed forces, friends, and allies from ballistic missile threats. The...infrastructure, land use, physical resources, noise, socioeconomics, transportation, and water resources. MDA determined that six of the thirteen resource

  17. BIOSURFACTANT-ENHANCED SOLUBILIZATION OF NAPL MIXTURES. (R827112)

    EPA Science Inventory

    Remediation of nonaqueous phase liquids (NAPLs) by conventional pump-and-treat methods (i.e., water flushing) is generally considered to be ineffective due to low water solubilities of NAPLs and to mass-transfer constraints. Chemical flushing techniques, such as surfactant flushi...

  18. Laboratory Investigations for the Role of Flushing Media in Diamond Drilling of Marble

    NASA Astrophysics Data System (ADS)

    Bhatnagar, A.; Khandelwal, Manoj; Rao, K. U. M.

    2011-05-01

    Marble is used as a natural stone for decorative purposes from ages. Marble is a crystalline rock, composed predominantly of calcite, dolomite or serpentine. The presence of impurities imparts decorative pattern and colors. The diamond-based operations are extensively used in the mining and processing of marble. Marble is mined out in the form of blocks of cuboids shape and has to undergo extensive processing to make it suitable for the end users. The processing operation includes slabbing, sizing, polishing, etc. Diamond drilling is also commonly used for the exploration of different mineral deposits throughout the world. In this paper an attempt has been made to enhance the performance of diamond drilling on marble rocks by adding polyethylene-oxide (PEO) in the flushing water. The effect of PEO added with the drilling water was studied by varying different machine parameters and flushing media concentration in the laboratory. The responses were rate of penetration and torque at bit-rock interface. Different physico-mechanical properties of marble were also determined. It was found that flushing water added with PEO can substantially enhance the penetration rates and reduce the torque developed at the bit-rock interface as compared to plain flushing water.

  19. Surfactant-enhanced flushing enhances colloid transport and alters macroporosity in diesel-contaminated soil.

    PubMed

    Guan, Zhuo; Tang, Xiang-Yu; Nishimura, Taku; Katou, Hidetaka; Liu, Hui-Yun; Qing, Jing

    2018-02-01

    Soil contamination by diesel has been often reported as a result of accidental spillage, leakage and inappropriate use. Surfactant-enhanced soil flushing is a common remediation technique for soils contaminated by hydrophobic organic chemicals. In this study, soil flushing with linear alkylbenzene sulfonates (LAS, an anionic surfactant) was conducted for intact columns (15cm in diameter and 12cm in length) of diesel-contaminated farmland purple soil aged for one year in the field. Dynamics of colloid concentration in column outflow during flushing, diesel removal rate and resulting soil macroporosity change by flushing were analyzed. Removal rate of n-alkanes (representing the diesel) varied with the depth of the topsoil in the range of 14%-96% while the n-alkanes present at low concentrations in the subsoil were completely removed by LAS-enhanced flushing. Much higher colloid concentrations and larger colloid sizes were observed during LAS flushing in column outflow compared to water flushing. The X-ray micro-computed tomography analysis of flushed and unflushed soil cores showed that the proportion of fine macropores (30-250μm in diameter) was reduced significantly by LAS flushing treatment. This phenomenon can be attributed to enhanced clogging of fine macropores by colloids which exhibited higher concentration due to better dispersion by LAS. It can be inferred from this study that the application of LAS-enhanced flushing technique in the purple soil region should be cautious regarding the possibility of rapid colloid-associated contaminant transport via preferential pathways in the subsurface and the clogging of water-conducting soil pores. Copyright © 2017. Published by Elsevier B.V.

  20. A bench-scale evaluation of the reuse of water at highway rest areas.

    DOT National Transportation Integrated Search

    1975-01-01

    A pilot laboratory treatment system was successfully employed to investigate the reuse of wastewater for flushing toilets at highway rest areas. This extended aeration unit used a synthetic waste to determine if the biological system could operate ef...

  1. Germinant-enhanced decontamination of Bacillus spores adhered to iron and cement-mortar drinking water infrastructures.

    PubMed

    Szabo, Jeffrey G; Muhammad, Nur; Heckman, Lee; Rice, Eugene W; Hall, John

    2012-04-01

    Germination was evaluated as an enhancement to decontamination methods for removing Bacillus spores from drinking water infrastructure. Germinating spores before chlorinating cement mortar or flushing corroded iron was more effective than chlorinating or flushing alone.

  2. Modeling the Flushing Response to the Construction of a Low Crested Weir in the Banana River

    NASA Astrophysics Data System (ADS)

    Saberi, A.; Weaver, R. J.

    2014-12-01

    The ADCIRC hydrodynamic model coupled with a Lagrangian Particle Tracking Model (LPTM) is applied to study circulation in the Banana River. The purpose of this study is to determine the extent to which constructing a low crested weir adjacent to Port Canaveral can improve flushing in this region. The Banana River a 50 km long sub-basin of the Indian River Lagoon (IRL), located on the central-east coast of Florida in Brevard County between Cape Canaveral and Merritt Island. Although Banana River has an outlet to the ocean through the Port Canaveral locks, the locks remain closed when there is no passing vessel resulting in limited circulation, long flushing time and poor water quality. Recent high mortality events of different species, e.g. dolphins, manatees and pelicans in the lagoon ecosystem, can be linked to the decline in the water quality. ADCIRC is used to simulate the hydrodynamic properties of the study area and determine the 2D depth-averaged velocity field for two separate cases: one with only tidal and another with both tidal and meteorological forces considered. Simulations are run, first to establish the baseline hydrodynamics of the unmodified system, and then to predict the effects of modifying the domain. Passive particles are placed in the Banana River portion of our domain, and the movement of these particles is tracked using LPTM for both cases. Flushing and residence time are then computed. Results indicate an improvement in flushing in both the Banana River and the central Indian River Lagoon, driven by an induced southerly current. In the portion of the Banana River to the south of the port complex, tidal flushing time is significantly reduced for the case of modified domain. In this southern region the flushing time based on 50% renewal time, is decreased from 100 days down to 15 days, after the addition of the weir to the domain.

  3. Microbial contamination of dental unit waterlines: short- and long-term effects of flushing.

    PubMed

    Santiago, J I; Huntington, M K; Johnston, A M; Quinn, R S; Williams, J F

    1994-01-01

    The extensive microbial contamination of DUW in this study is consistent with that described in previous reports. Comparisons with other common public potable water sources emphasize the relatively high concentrations of microorganisms in DUW, and the low numbers of bacteria in most domestic water samples. Microscopic evidence of amebas and worms in DUW reinforces the need for further qualitative and quantitative studies of these contaminants of dental tubing biofilm. In most cases, flushing for two minutes reduced microbial concentrations in DUW. However, in a few cases, concentrations rose; in others, the reductions were negligible. Moreover, after 30 minutes of stasis, or use of the waterline in a routine dental procedure, microbial counts were frequently restored to preflush levels or higher. The longer-term ineffectiveness 30 minutes after flushing is understandable when the hydrodynamics of laminar flow of water in narrow-bore tubing are considered. Biofilm on the tubing wall remains intact during flushes and quickly generates more bacteria during stasis. Increased bacterial concentrations after flushing probably result from sloughing of biofilm from the tubing wall because of stretching and movement of the line during routine use. These two phenomena undermine the benefits of routine water flushes. It is a common belief that bacterial levels build to extremes during overnight or weekend stasis; we observed more variation in contamination levels during the workday than between overnight stasis and typical workday samples. The presence of hemolytic staphylococci and streptococci in water samples from lines that were supplied only from sterile water reservoirs adds to the growing evidence that part of the microbial flora in DUWLs may be derived from patients' mouths. Additional prophylactic measures to limit bacterial contamination in DUW should be implemented according to standard principles used in other medical fluid delivery devices.

  4. Germinant-Enhanced Decontamination of Bacillus Spores Adhered to Iron and Cement-Mortar Drinking Water Infrastructures

    PubMed Central

    Muhammad, Nur; Heckman, Lee; Rice, Eugene W.; Hall, John

    2012-01-01

    Germination was evaluated as an enhancement to decontamination methods for removing Bacillus spores from drinking water infrastructure. Germinating spores before chlorinating cement mortar or flushing corroded iron was more effective than chlorinating or flushing alone. PMID:22267659

  5. First flush reactor for stormwater treatment for elevated linear transportation projects.

    DOT National Transportation Integrated Search

    2009-06-01

    The United States EPA (Environmental Protection Agency) MS4 (Municipal Separate Storm Water Sewer System) Program regulations : require municipalities and government agencies including the Louisiana Department of Transportation and Development (LADOT...

  6. Usefulness of a novel slim type FlushKnife-BT over conventional FlushKnife-BT in esophageal endoscopic submucosal dissection.

    PubMed

    Ohara, Yoshiko; Toyonaga, Takashi; Hoshi, Namiko; Tanaka, Shinwa; Baba, Shinichi; Takihara, Hiroshi; Kawara, Fumiaki; Ishida, Tsukasa; Morita, Yoshinori; Umegaki, Eiji; Azuma, Takeshi

    2017-03-07

    To investigated the usefulness of a novel slim type ball-tipped FlushKnife (FlushKnife-BTS) over ball-tipped FlushKnife (FlushKnife-BT) in functional experiments and clinical practice. In order to evaluate the functionality of FlushKnife-BTS, water aspiration speed, resistance to knife insertion through the scope, and waterjet flushing speed were compared between FlushKnife-BTS and BT. In clinical practice, esophageal endoscopic submucosal dissection (ESD) performed using FlushKnife-BTS or BT by an experienced endoscopist between October 2015 and January 2016 were retrospectively reviewed. The treatment speed and frequency of removing and reinserting the knife to aspirate fluid and air during ESD sessions were analyzed. Functional experiments revealed that water aspiration speed by the endoscope equipped with a 2.8-mm working channel with FlushKnife-BTS was 7.7-fold faster than that with conventional FlushKnife-BT. Resistance to knife insertion inside the scope with a 2.8-mm working channel was reduced by 40% with FlushKnife-BTS. The waterjet flushing speed was faster with the use of FlushKnife-BT. In clinical practice, a comparison of 6 and 7 ESD using FlushKnife-BT and BTS, respectively, revealed that the median treatment speed was 25.5 mm 2 /min (range 19.6-30.3) in the BT group and 44.2 mm 2 /min (range 15.5-55.4) in the BTS group ( P = 0.0633). However, the median treatment speed was significantly faster with FlushKnife-BTS when the resection size was larger than 1000 m 2 ( n = 4, median 24.2 mm 2 /min, range 19.6-27.7 vs n = 4, median 47.4 mm 2 /min, range 44.2-55.4, P = 0.0209). The frequency of knife replacement was less in the BTS group (median 1.76 times in one hour, range 0-5.45) than in the BT group (7.02 times in one hour, range 4.23-15) ( P = 0.0065). Our results indicate that FlushKnife-BTS enhances the performance of ESD, particularly for large lesions, by improving air and fluid aspiration and knife insertion during ESD and reducing the frequency of knife removal and reinsertion.

  7. Usefulness of a novel slim type FlushKnife-BT over conventional FlushKnife-BT in esophageal endoscopic submucosal dissection

    PubMed Central

    Ohara, Yoshiko; Toyonaga, Takashi; Hoshi, Namiko; Tanaka, Shinwa; Baba, Shinichi; Takihara, Hiroshi; Kawara, Fumiaki; Ishida, Tsukasa; Morita, Yoshinori; Umegaki, Eiji; Azuma, Takeshi

    2017-01-01

    AIM To investigated the usefulness of a novel slim type ball-tipped FlushKnife (FlushKnife-BTS) over ball-tipped FlushKnife (FlushKnife-BT) in functional experiments and clinical practice. METHODS In order to evaluate the functionality of FlushKnife-BTS, water aspiration speed, resistance to knife insertion through the scope, and waterjet flushing speed were compared between FlushKnife-BTS and BT. In clinical practice, esophageal endoscopic submucosal dissection (ESD) performed using FlushKnife-BTS or BT by an experienced endoscopist between October 2015 and January 2016 were retrospectively reviewed. The treatment speed and frequency of removing and reinserting the knife to aspirate fluid and air during ESD sessions were analyzed. RESULTS Functional experiments revealed that water aspiration speed by the endoscope equipped with a 2.8-mm working channel with FlushKnife-BTS was 7.7-fold faster than that with conventional FlushKnife-BT. Resistance to knife insertion inside the scope with a 2.8-mm working channel was reduced by 40% with FlushKnife-BTS. The waterjet flushing speed was faster with the use of FlushKnife-BT. In clinical practice, a comparison of 6 and 7 ESD using FlushKnife-BT and BTS, respectively, revealed that the median treatment speed was 25.5 mm2/min (range 19.6-30.3) in the BT group and 44.2 mm2/min (range 15.5-55.4) in the BTS group (P = 0.0633). However, the median treatment speed was significantly faster with FlushKnife-BTS when the resection size was larger than 1000 m2 (n = 4, median 24.2 mm2/min, range 19.6-27.7 vs n = 4, median 47.4 mm2/min, range 44.2-55.4, P = 0.0209). The frequency of knife replacement was less in the BTS group (median 1.76 times in one hour, range 0-5.45) than in the BT group (7.02 times in one hour, range 4.23-15) (P = 0.0065). CONCLUSION Our results indicate that FlushKnife-BTS enhances the performance of ESD, particularly for large lesions, by improving air and fluid aspiration and knife insertion during ESD and reducing the frequency of knife removal and reinsertion. PMID:28321167

  8. HARVESTING ROOFTOP RUNOFF FROM RDP HOUSING IN SOUTH AFRICA: A PRAGMATIC APPROACH TO SUPPLEMENT WATER SUPPLY WHILE REDUCING FLOODING, SOIL EROSION, AND DISEASE

    EPA Science Inventory

    The team was able to design a shuttle valve and full scale rainwater collection system that, in times of enough rainfall, provided an extra free source of water to flush toilets. Based of the dimensions of the RDP house and the tank size, the system should be able to collec...

  9. APPENDIX C - ADDITIONAL INFORMATION ON FLUSHING IN ESTUARIES

    EPA Science Inventory

    Water residence time is an important determinant of the sensitivity of the response of estuaries and other water bodies to nutrient loading. A variety of terms such as residence time, flushing time, transit time, turnover time, and age are used to describe time scales for transpo...

  10. Risk in the mist? Deriving data to quantify microbial health risks associated with aerosol generation by water-efficient devices during typical domestic water-using activities.

    PubMed

    O'Toole, J; Keywood, M; Sinclair, M; Leder, K

    2009-01-01

    The aim of this study was to address existing data gaps and to determine the size distribution of aerosols associated with water-efficient devices during typical domestic activities. This information is important to assist in understanding infection spread during water-using activities and in designing water regulations. Three water-using scenarios were evaluated: i) showering using a water-efficient showerhead; ii) use of a high pressure spray unit for cleaning cars and iii) toilet flushing using a dual flush low volume flush device. For each scenario a control condition (conventional lower efficiency device) was selected for benchmarking purposes. Shower module results highlighted the complexity of particle generation and removal processes and showed that more than 90% of total particle mass in the breathing zone was attributed to particle diameters greater than 6 mum. Conversely, results for car washing experiments showed that particle diameters up to 6 mum constituted the major part of the total mass generated by both water-efficient and conventional devices. Even under worse case scenario conditions for toilet flushing, particle measurements were at or below the level of detection of the measuring instrumentation. The data provide information that assists in health risk assessment and in determining future research directions, including methodological aspects.

  11. Water quality effects of intermittent water supply in Arraiján, Panama.

    PubMed

    Erickson, John J; Smith, Charlotte D; Goodridge, Amador; Nelson, Kara L

    2017-05-01

    Intermittent drinking water supply is common in low- and middle-income countries throughout the world and can cause water quality to degrade in the distribution system. In this study, we characterized water quality in one study zone with continuous supply and three zones with intermittent supply in the drinking water distribution network in Arraiján, Panama. Low or zero pressures occurred in all zones, and negative pressures occurred in the continuous zone and two of the intermittent zones. Despite hydraulic conditions that created risks for backflow and contaminant intrusion, only four of 423 (0.9%) grab samples collected at random times were positive for total coliform bacteria and only one was positive for E. coli. Only nine of 496 (1.8%) samples had turbidity >1.0 NTU and all samples had ≥0.2 mg/L free chlorine residual. In contrast, water quality was often degraded during the first-flush period (when supply first returned after an outage). Still, routine and first-flush water quality under intermittent supply was much better in Arraiján than that reported in a previous study conducted in India. Better water quality in Arraiján could be due to better water quality leaving the treatment plant, shorter supply outages, higher supply pressures, a more consistent and higher chlorine residual, and fewer contaminant sources near pipes. The results illustrate that intermittent supply and its effects on water quality can vary greatly between and within distribution networks. The study also demonstrated that monitoring techniques designed specifically for intermittent supply, such as continuous pressure monitoring and sampling the first flush, can detect water quality threats and degradation that would not likely be detected with conventional monitoring. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. Tidal flushing and wind driven circulation of Ahe atoll lagoon (Tuamotu Archipelago, French Polynesia) from in situ observations and numerical modelling.

    PubMed

    Dumas, F; Le Gendre, R; Thomas, Y; Andréfouët, S

    2012-01-01

    Hydrodynamic functioning and water circulation of the semi-closed deep lagoon of Ahe atoll (Tuamotu Archipelago, French Polynesia) were investigated using 1 year of field data and a 3D hydrodynamical model. Tidal amplitude averaged less than 30 cm, but tide generated very strong currents (2 ms(-1)) in the pass, creating a jet-like circulation that partitioned the lagoon into three residual circulation cells. The pass entirely flushed excess water brought by waves-induced radiation stress. Circulation patterns were computed for climatological meteorological conditions and summarized with stream function and flushing time. Lagoon hydrodynamics and general overturning circulation was driven by wind. Renewal time was 250 days, whereas the e-flushing time yielded a lagoon-wide 80-days average. Tide-driven flush through the pass and wind-driven overturning circulation designate Ahe as a wind-driven, tidally and weakly wave-flushed deep lagoon. The 3D model allows studying pearl oyster larvae dispersal in both realistic and climatological conditions for aquaculture applications. Copyright © 2012 Elsevier Ltd. All rights reserved.

  13. Comparing Properties of Water Absorbing/Filtering Media for Bioslope/Bioswale Design

    DOT National Transportation Integrated Search

    2017-11-01

    Drainage from highways, particularly the first flush of runoff, contains high levels of contaminants such as suspended solids, metals, and organics. To restrict the discharge of polluted stormwater, the National Pollutant Discharge Elimination System...

  14. The bacteriological composition of biomass recovered by flushing an operational drinking water distribution system.

    PubMed

    Douterelo, I; Husband, S; Boxall, J B

    2014-05-01

    This study investigates the influence of pipe characteristics on the bacteriological composition of material mobilised from a drinking water distribution system (DWDS) and the impact of biofilm removal on water quality. Hydrants in a single UK Distribution Management Area (DMA) with both polyethylene and cast iron pipe sections were subjected to incremental increases in flow to mobilise material from the pipe walls. Turbidity was monitored during these operations and water samples were collected for physico-chemical and bacteriological analysis. DNA was extracted from the material mobilised into the bulk water before and during flushing. Bacterial tag-encoded 454 pyrosequencing was then used to characterize the bacterial communities present in this material. Turbidity values were high in the samples from cast iron pipes. Iron, aluminium, manganese and phosphate concentrations were found to correlate to observed turbidity. The bacterial community composition of the material mobilised from the pipes was significantly different between plastic and cast iron pipe sections (p < 0.5). High relative abundances of Alphaproteobacteria (23.3%), Clostridia (10.3%) and Actinobacteria (10.3%) were detected in the material removed from plastic pipes. Sequences related to Alphaproteobacteria (22.8%), Bacilli (16.6%), and Gammaproteobacteria (1.4%) were predominant in the samples obtained from cast iron pipes. The highest species richness and diversity were found in the samples from material mobilised from plastic pipes. Spirochaeta spp., Methylobacterium spp. Clostridium spp. and Desulfobacterium spp., were the most represented genera in the material obtained prior to and during the flushing of the plastic pipes. In cast iron pipes a high relative abundance of bacteria able to utilise different iron and manganese compounds were found such as Lysinibacillus spp., Geobacillus spp. and Magnetobacterium spp. Copyright © 2014 Elsevier Ltd. All rights reserved.

  15. Copper in household drinking water in the city of Zagreb, Croatia.

    PubMed

    Pizent, Alica; Butković, Sanja

    2010-09-01

    Copper concentration was estimated in tap water samples obtained from 70 households in Zagreb, serviced by a public water supply system. First-draw and flushed samples of tap water were collected in the morning and total copper concentration was determined by graphite furnace atomic absorption spectrometry with Zeeman-effect background correction. We also estimated the contribution of plumbing material to copper concentrations in tap water. In households with copper pipes, median and range copper values were 310 μg L-1 [(27 to 632) μg L-1] in first-draw samples and 16 μg L-1 [(5 to 52) μg L-1] in flushed samples. Corresponding values for households with galvanised pipes were 140 μg L-1 [(11 to 289) μg L-1] and 8 μg L-1 [(1 to 42) μg L-1], respectively. Copper concentrations in household tap water in Zagreb were far below the proposed safe limits set by the Croatian and WHO regulations and EPA standards, and drinking water in Zagreb is not a significant source of copper exposure.

  16. First flush reactor for stormwater treatment for elevated linear transportation projects : tech summary.

    DOT National Transportation Integrated Search

    2009-06-01

    The U.S. Environmental Protection Agency (EPA) Municipal Separate Storm Water Sewer System (MS4) Program : regulations require municipalities and government agencies including the Louisiana Department of Transportation : and Development (LADOTD) to d...

  17. A hazard of the Intraflo continuous flush system.

    PubMed

    Schwartz, A J; Stoner, B B; Jobes, D R

    1977-01-01

    Patency of pressure sensing systems can be provided by the Intraflow Continuous Flush System (Sorenson Research Company, Salt Lake City, UT 84115). This device allows continuous flow of flush solution through a regulatory valve while preventing transmission of the high pressure of the flush solution. The case presented describes the recognition of a false elevation of a monitored pressure secondary to the malfunction of the Intraflo regulatory valve. Elimination of the flush solution high pressure during monitoring prevents inappropriate data collection.

  18. CAD and CAE Analysis for Siphon Jet Toilet

    NASA Astrophysics Data System (ADS)

    Wang, Yuhua; Xiu, Guoji; Tan, Haishu

    The high precision 3D laser scanner with the dual CCD technology was used to measure the original design sample of a siphon jet toilet. The digital toilet model was constructed from the cloud data measured with the curve and surface fitting technology and the CAD/CAE systems. The Realizable k - ɛ double equation model of the turbulence viscosity coefficient method and the VOF multiphase flow model were used to simulate the flushing flow in the toilet digital model. Through simulating and analyzing the distribution of the flushing flow's total pressure, the flow speed at the toilet-basin surface and the siphoning bent tube, the toilet performance can be evaluated efficiently and conveniently. The method of "establishing digital model, flushing flow simulating, performances evaluating, function shape modifying" would provide a high efficiency approach to develop new water-saving toilets.

  19. Temperature dynamics of stormwater runoff in Australia and the USA.

    PubMed

    Hathaway, J M; Winston, R J; Brown, R A; Hunt, W F; McCarthy, D T

    2016-07-15

    Thermal pollution of surface waters by urban stormwater runoff is an often overlooked by-product of urbanization. Elevated stream temperatures due to an influx of stormwater runoff can be detrimental to stream biota, in particular for cold water systems. However, few studies have examined temperature trends throughout storm events to determine how these thermal inputs are temporally distributed. In this study, six diverse catchments in two continents are evaluated for thermal dynamics. Summary statistics from the data showed larger catchments have lower maximum runoff temperatures, minimum runoff temperatures, and temperature variability. This reinforces the understanding that subsurface drainage infrastructure in urban catchments acts to moderate runoff temperatures. The catchments were also evaluated for the presence of a thermal first flush using two methodologies. Results showed the lack of a first flush under traditional assessment methodologies across all six catchments, supporting the results from a limited number of studies in literature. However, the time to peak temperature was not always coincident with the time to peak flow, highlighting the variability of thermal load over time. When a new first flush methodology was applied, significant differences in temperature were noted with increasing runoff depth for five of the six sites. This study is the first to identify a runoff temperature first flush, and highlights the need to carefully consider the appropriate methodology for such analyses. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. The flushing and exchange of the South China Sea derived from salt and mass conservation

    NASA Astrophysics Data System (ADS)

    Liu, Yang; Bye, John A. T.; You, Yuzhu; Bao, Xianwen; Wu, Dexing

    2010-07-01

    In this paper, we use two kinds of hydrographic data, historical cruise data, Array for Real-time Geostrophic Oceanography (Argo) float data, and atmospheric data to study the water exchange between the South China Sea (SCS) and the Pacific Ocean through the Luzon Strait. The annual mean distributions of temperature and salinity at five different levels in the SCS and the adjacent Pacific Ocean are presented, which indicate the occurrence of active water exchange through the Luzon Strait. The flushing and exchange of the SCS are then determined by the application of salt and mass conservation in a multi-layered thermohaline system, using an estimate of the net rainfall obtained from reanalysis data. The results show that the annual mean flushing time is 44±8 months with an inflow rate of 11±2 Sv (1 Sv=10 6 m 3 s -1), part of which recirculates at a deeper level through the Luzon Strait, the remainder (6±2 Sv) forming the SCS throughflow. The diffusive influx of salt is also estimated and accounts for about 10% of the total influx, and hence advection dominates over diffusion in the water exchange through the Luzon Strait. The seasonal cycle of exchange shows a maximum in autumn and winter of about twice the annual mean rate.

  1. Hydrological versus biogeochemical controls on catchment nitrate export: a test of the flushing mechanism

    NASA Astrophysics Data System (ADS)

    Ocampo, Carlos J.; Oldham, Carolyn E.; Sivapalan, Murugesu; Turner, Jeffrey V.

    2006-12-01

    Deciphering the connection between streamflows and nitrate (NO-3) discharge requires identification of the various water flow pathways within a catchment, and the different time-scales at which hydrological and biogeochemical processes occur. Despite the complexity of the processes involved, many catchments around the world present a characteristic flushing response of NO-3 export. Yet the controls on the flushing response, and how they vary across space and time, are still not clearly understood. In this paper, the flushing response of NO-3 export from a rural catchment in Western Australia was investigated using isotopic (deuterium), chemical (chloride, NO-3), and hydrometric data across different antecedent conditions and time-scales. The catchment streamflow was at all time-scales dominated by a pre-event water source, and the NO-3 discharge was correlated with the magnitude of areas contributing to saturation overland flow. The NO-3 discharge also appeared related to the shallow groundwater dynamics. Thus, the antecedent moisture condition of the catchment at seasonal and interannual time-scales had a major impact on the NO-3 flushing response. In particular, the dynamics of the shallow ephemeral perched aquifer drove a shift from hydrological controls on NO-3 discharge during the early flushing stage to an apparent biogeochemical control on NO-3 discharge during the steady decline stage of the flushing response. This temporally variable control hypothesis provides a new and alternative description of the mechanisms behind the commonly seen flushing response. Copyright

  2. Memo Clarifying Recommended Tap Sampling Procedures for the Lead and Copper Rule

    EPA Pesticide Factsheets

    EPA has recently published a memo to provide recommendations on how public water systems should address the removal of cleaning aerators, pre-stagnation flushing, and bottle configuration for the purpose of the Lead and Copper Rule.

  3. Endoscope system with plasma flushing and coaxial round jet nozzle for off-pump cardiac surgery.

    PubMed

    Horiuchi, Tetsuya; Masamune, Ken; Iwase, Yuki; Ymashita, Hiromasa; Tsukihara, Hiroyuki; Motomura, Noboru; Ohta, Yuji; Dohi, Takeyoshi

    2011-07-01

    To develop a new endoscope for performing simple surgical tasks inside the blood-filled cardiac atrium/chamber, that is, "off-pump" cardiac surgeries. We developed the endoscope system with plasma flushing and coaxial round jet nozzle. The "plasma flushing" system was invented to observe the interior of the blood-filled heart by displacing blood cells in front of the endoscope tip. However, some areas could not be observed with simple flushing of the liquid because the flushed liquid mixed with blood. Further, a large amount of liquid had to be flushed, which posed a risk of cardiac damage caused by excess volume. Therefore, to safely capture high-resolution images of the interior of the heart, an endoscope with a coaxial round jet nozzle through which plasma is flushed has been developed. And to reduce the volume of flushed liquid, the synchronization system of heartbeat and the endoscope system with plasma flushing has been developed. We conducted an in vivo experiment to determine whether we could observe intracardiac tissues in swine without the use of a heart-lung machine. As a result, we successfully observed intracardiac tissues without using a heart-lung machine. By using a coaxial nozzle, we could even observe the tricuspid valve. Moreover, we were able to save up to 30% of the flushed liquid by replacing the original system with a synchronization system. And we evaluated the performance of the endoscope with the coaxial round jet nozzle by conducting fluid analysis and an in vitro experiment. We successfully observed intracardiac tissues without using a heart-lung machine. By using a coaxial nozzle, we could even observe the tricuspid valve. And by replacing an original system to a synchronization system, we were able to save up to 30% of the flushed liquid. As a follow-up study, we plan to create a surgical flexible device for valve disease that can grasp, staple, and repair cardiac valves by endoscopic visualization.

  4. Monitoring on The Quality and Quantity of DIY Rainwater Harvesting System

    NASA Astrophysics Data System (ADS)

    Kasmin, H.; Bakar, N. H.; Zubir, M. M.

    2016-07-01

    Rainwater harvesting is an alternative sources of water supply and can be used for potable and non-potable uses. It could helps to store treated rainwater for more beneficial use and also for flood mitigation. Sustainable approach for flooding problem reduction in urban areas is by slowing down the rate of surface runoff flows at source by providing more storage area/tank. In order to understand the performance of a rainwater harvesting system (RWH), a preliminary monitoring on a ‘do it yourself’ (DIY) RWH model with additional first -flush strategy for water quality treatment was done. The main concept behind first flush diversion is to prevent initial polluted rainwater from entering the storage tank. Based on seven rainfall events observed in Parit Raja, both quality and quantity of the rainfalls were analysed. For rainwater quality, the samples from first flush diverter and storage tank were taken to understand their performance based on pH, dissolved oxygen (DO), turbidity, total dissolved solid (TDS), total suspended solid (TSS), chemical oxygen demand (COD) and biochemical oxygen demand (BOD) parameters. While for rainwater quantity, hydrograph analysis were done based on the performance of total rainfall and runoff, peak flow of rainfall and runoff; and delayed time parameters. Based on Interim National Water Quality Standard (INWQS) and National Drinking Water Quality Standard (NDWQS), first flush diverter apparently helps on water quality improvement in storage tanks when pH, DO, TDS, TSS and turbidity were classified as Class I (INWQS) and is allowable for drinking; but BOD and COD parameters were classified as Class III (INWQS). Hence, it has potential to be used as potable usage but will need extensive treatment to reduce its poor microbial quality. Based on the maximum observed rainfall event which had total volume of 3195.5 liter, had peakflow reduction from 0.00071 m3/s to 0.00034 m3/s and delayed runoff between 5 and 10 minutes after rainfall started. It concludes that the performance of water retention could be due to total rainfall and the tank capacity. Therefore, RWH has a potential to be used as potable use and at the same time it also has a potential to reduce local urban flooding.

  5. Laboratory investigation of flux reduction from dense non-aqueous phase liquid (DNAPL) partial source zone remediation by enhanced dissolution

    NASA Astrophysics Data System (ADS)

    Kaye, Andrew J.; Cho, Jaehyun; Basu, Nandita B.; Chen, Xiaosong; Annable, Michael D.; Jawitz, James W.

    2008-11-01

    This study investigated the benefits of partial removal of dense nonaqueous phase liquid (DNAPL) source zones using enhanced dissolution in eight laboratory scale experiments. The benefits were assessed by characterizing the relationship between reductions in DNAPL mass and the corresponding reduction in contaminant mass flux. Four flushing agents were evaluated in eight controlled laboratory experiments to examine the effects of displacement fluid property contrasts and associated override and underride on contaminant flux reduction ( Rj) vs. mass reduction ( Rm) relationships ( Rj( Rm)): 1) 50% ethanol/50% water (less dense than water), 2) 40% ethyl-lactate/60% water (more dense than water), 3) 18% ethanol/26% ethyl-lactate/56% water (neutrally buoyant), and 4) 2% Tween-80 surfactant (also neutrally buoyant). For each DNAPL architecture evaluated, replicate experiments were conducted where source zone dissolution was conducted with a single flushing event to remove most of the DNAPL from the system, and with multiple shorter-duration floods to determine the path of the Rj( Rm) relationship. All of the single-flushing experiments exhibited similar Rj( Rm) relationships indicating that override and underride effects associated with cosolvents did not significantly affect the remediation performance of the agents. The Rj( Rm) relationship of the multiple injection experiments for the cosolvents with a density contrast with water tended to be less desirable in the sense that there was less Rj for a given Rm. UTCHEM simulations supported the observations from the laboratory experiments and demonstrated the capability of this model to predict Rj( Rm) relationships for non-uniformly distributed NAPL sources.

  6. Operator’s Manual for UH-60A Helicopter, UH-60L Helicopter, EH-60A Helicopter

    DTIC Science & Technology

    1996-10-31

    electrolyte is harmful to the skin and clothing. If potassium hydroxide is spilled on clothing or other material, wash immediately with clean water . If spilled...on personnel, immediately flush the affected area with clean water . Continue washing until medical assistance arrives. Neutralize any spilled...electrolyte by thoroughly flushing contacted area with water . CARBON MONOXIDE When smoke, suspected carbon monoxide fumes, or symptoms of anoxia exist, the

  7. Baobab trees (Adansonia) in Madagascar use stored water to flush new leaves but not to support stomatal opening before the rainy season.

    PubMed

    Chapotin, Saharah Moon; Razanameharizaka, Juvet H; Holbrook, N Michele

    2006-01-01

    Baobab trees (Adansonia, Bombacaceae) are widely thought to store water in their stems for use when water availability is low. We tested this hypothesis by assessing the role of stored water during the dry season in three baobab species in Madagascar. In the dry season, leaves are present only during and after leaf flush. We quantified the relative contributions of stem and soil water during this period through measures of stem water content, sap flow and stomatal conductance. Rates of sap flow at the base of the trunk were near zero, indicating that leaf flushing was almost entirely dependent on stem water. Stem water content declined by up to 12% during this period, yet stomatal conductance and branch sap flow rates remained very low. Stem water reserves were used to support new leaf growth and cuticular transpiration, but not to support stomatal opening before the rainy season. Stomatal opening coincided with the onset of sap flow at the base of the trunk and occurred only after significant rainfall.

  8. Indoor Heating Drives Water Bacterial Growth and Community Metabolic Profile Changes in Building Tap Pipes during the Winter Season

    PubMed Central

    Zhang, Hai-Han; Chen, Sheng-Nan; Huang, Ting-Lin; Shang, Pan-Lu; Yang, Xiao; Ma, Wei-Xing

    2015-01-01

    The growth of the bacterial community harbored in indoor drinking water taps is regulated by external environmental factors, such as indoor temperature. However, the effect of indoor heating on bacterial regrowth associated with indoor drinking water taps is poorly understood. In the present work, flow cytometry and community-level sole-carbon-source utilization techniques were combined to explore the effects of indoor heating on water bacterial cell concentrations and community carbon metabolic profiles in building tap pipes during the winter season. The results showed that the temperature of water stagnated overnight (“before”) in the indoor water pipes was 15–17 °C, and the water temperature decreased to 4–6 °C after flushing for 10 min (“flushed”). The highest bacterial cell number was observed in water stagnated overnight, and was 5–11 times higher than that of flushed water. Meanwhile, a significantly higher bacterial community metabolic activity (AWCD590nm) was also found in overnight stagnation water samples. The significant “flushed” and “taps” values indicated that the AWCD590nm, and bacterial cell number varied among the taps within the flushed group (p < 0.01). Heatmap fingerprints and principle component analyses (PCA) revealed a significant discrimination bacterial community functional metabolic profiles in the water stagnated overnight and flushed water. Serine, threonine, glucose-phosphate, ketobutyric acid, phenylethylamine, glycerol, putrescine were significantly used by “before” water samples. The results suggested that water stagnated at higher temperature should be treated before drinking because of bacterial regrowth. The data from this work provides useful information on reasonable utilization of drinking water after stagnation in indoor pipes during indoor heating periods. PMID:26516885

  9. EGS rock reactions with Supercritical CO2 saturated with water and water saturated with Supercritical CO2

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Earl D. Mattson; Travis L. McLing; William Smith

    2013-02-01

    EGS using CO2 as a working fluid will likely involve hydro-shearing low-permeability hot rock reservoirs with a water solution. After that process, the fractures will be flushed with CO2 that is maintained under supercritical conditions (> 70 bars). Much of the injected water in the main fracture will be flushed out with the initial CO2 injection; however side fractures, micro fractures, and the lower portion of the fracture will contain connate water that will interact with the rock and the injected CO2. Dissolution/precipitation reactions in the resulting scCO2/brine/rock systems have the potential to significantly alter reservoir permeability, so it ismore » important to understand where these precipitates form and how are they related to the evolving ‘free’ connate water in the system. To examine dissolution / precipitation behavior in such systems over time, we have conducted non-stirred batch experiments in the laboratory with pure minerals, sandstone, and basalt coupons with brine solution spiked with MnCl2 and scCO2. The coupons are exposed to liquid water saturated with scCO2 and extend above the water surface allowing the upper portion of the coupons to be exposed to scCO2 saturated with water. The coupons were subsequently analyzed using SEM to determine the location of reactions in both in and out of the liquid water. Results of these will be summarized with regard to significance for EGS with CO2 as a working fluid.« less

  10. Toilets Specification and Certification

    EPA Pesticide Factsheets

    Recent advancements have allowed toilets to use 1.28 gallons per flush or less while still providing equal or superior performance. This is 20 percent less water than the current federal standard of 1.6 gallons per flush.

  11. Decision Support on the Sediments Flushing of Aimorés Dam Using Medium-Range Ensemble Forecasts

    NASA Astrophysics Data System (ADS)

    Mainardi Fan, Fernando; Schwanenberg, Dirk; Collischonn, Walter; Assis dos Reis, Alberto; Alvarado Montero, Rodolfo; Alencar Siqueira, Vinicius

    2015-04-01

    In the present study we investigate the use of medium-range streamflow forecasts in the Doce River basin (Brazil), at the reservoir of Aimorés Hydro Power Plant (HPP). During daily operations this reservoir acts as a "trap" to the sediments that originate from the upstream basin of the Doce River. This motivates a cleaning process called "pass through" to periodically remove the sediments from the reservoir. The "pass through" or "sediments flushing" process consists of a decrease of the reservoir's water level to a certain flushing level when a determined reservoir inflow threshold is forecasted. Then, the water in the approaching inflow is used to flush the sediments from the reservoir through the spillway and to recover the original reservoir storage. To be triggered, the sediments flushing operation requires an inflow larger than 3000m³/s in a forecast horizon of 7 days. This lead-time of 7 days is far beyond the basin's concentration time (around 2 days), meaning that the forecasts for the pass through procedure highly depends on Numerical Weather Predictions (NWP) models that generate Quantitative Precipitation Forecasts (QPF). This dependency creates an environment with a high amount of uncertainty to the operator. To support the decision making at Aimorés HPP we developed a fully operational hydrological forecasting system to the basin. The system is capable of generating ensemble streamflow forecasts scenarios when driven by QPF data from meteorological Ensemble Prediction Systems (EPS). This approach allows accounting for uncertainties in the NWP at a decision making level. This system is starting to be used operationally by CEMIG and is the one shown in the present study, including a hindcasting analysis to assess the performance of the system for the specific flushing problem. The QPF data used in the hindcasting study was derived from the TIGGE (THORPEX Interactive Grand Global Ensemble) database. Among all EPS available on TIGGE, three were selected: ECMWF, GEFS, and CPTEC. As a deterministic reference forecast, we adopt the high resolution ECMWF forecast for comparison. The experiment consisted on running retrospective forecasts for a full five-year period. To verify the proposed objectives of the study, we use different metrics to evaluate the forecast: ROC Curves, Exceedance Diagrams, Forecast Convergence Score (FCS). Metrics results enabled to understand the benefits of the hydrological ensemble prediction system as a decision making tool for the HPP operation. The ROC scores indicate that the use of the lower percentiles of the ensemble scenarios issues for a true alarm rate around 0,5 to 0,8 (depending on the model and on the percentile), for the lead time of seven days. While the false alarm rate is between 0 and 0,3. Those rates were better than the ones resulting from the deterministic reference forecast. Exceedance diagrams and forecast convergence scores indicate that the ensemble scenarios provide an early signal about the threshold crossing. Furthermore, the ensemble forecasts are more consistent between two subsequent forecasts in comparison to the deterministic forecast. The assessments results also give more credibility to CEMIG in the realization and communication of flushing operation with the stakeholders involved.

  12. Environmental Effects of Storage Preservation Practices: Controlled Flushing of Fine Sediment from a Small Hydropower Reservoir

    NASA Astrophysics Data System (ADS)

    Espa, Paolo; Castelli, Elena; Crosa, Giuseppe; Gentili, Gaetano

    2013-07-01

    Sediment flushing may be effective in mitigating loss of reservoir storage due to siltation, but flushing must be controlled to limit the impact on the downstream environment. A reliable prediction of the environmental effects of sediment flushing is hindered by the limited scientific information currently available. Consequently, there may be some controversy as regards to management decisions, planning the work, and monitoring strategies. This paper summarizes the main results of a monitoring campaign on the stream below a small alpine hydropower reservoir subjected to annual flushing between 2006 and 2009. The removed sediment was essentially silt, and the suspended solid concentration (SSC) of the discharged water was controlled to alleviate downstream impact. Control was achieved through hydraulic regulation and mechanical digging, alternating daytime sediment evacuation, and nocturnal clear water release. The four operations lasted about two weeks each and had an average SSC of about 4 g L-1. Maximum values of SSC were generally kept below 10 g L-1. Downstream impact was quantified through sampling of fish fauna (brown trout) and macroinvertebrate in the final reach of the effluent stream. The benthic community was severely impaired by the flushing operations, but recovered to pre-flushing values in a few months. As expected, the impact on brown trout was heavier on juveniles. While data biasing due to fish removal and re-stocking cannot be ruled out, the fish community seems to have reached a state of equilibrium characterized by a lower density than was measured before the flushing operations.

  13. Environmental effects of storage preservation practices: controlled flushing of fine sediment from a small hydropower reservoir.

    PubMed

    Espa, Paolo; Castelli, Elena; Crosa, Giuseppe; Gentili, Gaetano

    2013-07-01

    Sediment flushing may be effective in mitigating loss of reservoir storage due to siltation, but flushing must be controlled to limit the impact on the downstream environment. A reliable prediction of the environmental effects of sediment flushing is hindered by the limited scientific information currently available. Consequently, there may be some controversy as regards to management decisions, planning the work, and monitoring strategies. This paper summarizes the main results of a monitoring campaign on the stream below a small alpine hydropower reservoir subjected to annual flushing between 2006 and 2009. The removed sediment was essentially silt, and the suspended solid concentration (SSC) of the discharged water was controlled to alleviate downstream impact. Control was achieved through hydraulic regulation and mechanical digging, alternating daytime sediment evacuation, and nocturnal clear water release. The four operations lasted about two weeks each and had an average SSC of about 4 g L(-1). Maximum values of SSC were generally kept below 10 g L(-1). Downstream impact was quantified through sampling of fish fauna (brown trout) and macroinvertebrate in the final reach of the effluent stream. The benthic community was severely impaired by the flushing operations, but recovered to pre-flushing values in a few months. As expected, the impact on brown trout was heavier on juveniles. While data biasing due to fish removal and re-stocking cannot be ruled out, the fish community seems to have reached a state of equilibrium characterized by a lower density than was measured before the flushing operations.

  14. Phytoplankton and water quality in a Mediterranean drinking-water reservoir (Marathonas Reservoir, Greece).

    PubMed

    Katsiapi, Matina; Moustaka-Gouni, Maria; Michaloudi, Evangelia; Kormas, Konstantinos Ar

    2011-10-01

    Phytoplankton and water quality of Marathonas drinking-water Reservoir were examined for the first time. During the study period (July-September 2007), phytoplankton composition was indicative of eutrophic conditions although phytoplankton biovolume was low (max. 2.7 mm³ l⁻¹). Phytoplankton was dominated by cyanobacteria and diatoms, whereas desmids and dinoflagellates contributed with lower biovolume values. Changing flushing rate in the reservoir (up to 0.7% of reservoir's water volume per day) driven by water withdrawal and occurring in pulses for a period of 15-25 days was associated with phytoplankton dynamics. Under flushing pulses: (1) biovolume was low and (2) both 'good' quality species and the tolerant to flushing 'nuisance' cyanobacterium Microcystis aeruginosa dominated. According to the Water Framework Directive, the metrics of phytoplankton biovolume and cyanobacterial percentage (%) contribution indicated a moderate ecological water quality. In addition, the total biovolume of cyanobacteria as well as the dominance of the known toxin-producing M. aeruginosa in the reservoir's phytoplankton indicated a potential hazard for human health according to the World Health Organization.

  15. Electrochemical disinfection of repeatedly recycled blackwater in a free‐standing, additive‐free toilet

    PubMed Central

    Sellgren, Katelyn L.; Klem, Ethan J. D.; Piascik, Jeffrey R.; Stoner, Brian R.

    2017-01-01

    Abstract Decentralized, energy‐efficient waste water treatment technologies enabling water reuse are needed to sustainably address sanitation needs in water‐ and energy‐scarce environments. Here, we describe the effects of repeated recycling of disinfected blackwater (as flush liquid) on the energy required to achieve full disinfection with an electrochemical process in a prototype toilet system. The recycled liquid rapidly reached a steady state with total solids reliably ranging between 0.50 and 0.65% and conductivity between 20 and 23 mS/cm through many flush cycles over 15 weeks. The increase in accumulated solids was associated with increased energy demand and wide variation in the free chlorine contact time required to achieve complete disinfection. Further studies on the system at steady state revealed that running at higher voltage modestly improves energy efficiency, and established running parameters that reliably achieve disinfection at fixed run times. These results will guide prototype testing in the field. PMID:29242713

  16. Effects of a spring flushing flow on the distribution of radio-tagged juvenile rainbow trout in a Wyoming tailwater

    USGS Publications Warehouse

    Simpkins, D.G.; Hubert, W.A.; Wesche, T.A.

    2000-01-01

    The controlled release of dammed water, designed to produce a flushing flow that would remove fine sediments from spawning habitat in a flow-regulated river, did not displace juvenile rainbow trout Oncorhynchus mykiss (20-25 cm total length) downstream. Of eight naturally spawned (wild) and nine hatchery fish that were radio-tagged, only one wild fish and two hatchery fish were found in different locations after an eight-fold increase in flow. These three fish moved upstream and the greatest movement was 96 m. Cobble and boulder substrates in main-channel pools were thought to provide slow-water-velocity refuges during the flushing flow. Our findings and the findings of other researchers suggest that flushing flows can be conducted to enhance spawning habitat for rainbow trout without causing extensive downstream movements or habitat displacement of small fish in regulated rivers.

  17. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fowler, Kimberly M.; Kora, Angela R.

    This report is a summary of the water analysis performance for the Denver, Colorado Wynkoop Building. The Wynkoop Building (Figure 1) was built in 2006 as the Environmental Protection Agency (EPA) Region 8 Headquarters intended to house over 900 occupants in the 301,292 gross square feet (248,849 rentable square feet). The building was built on a brownfield in the Lower Downtown Historic District as part of an urban redevelopment effort. The building was designed and constructed through a public-private partnership with the sustainable design elements developed jointly by General Services Administration (GSA) and EPA. That partnership is still active withmore » all parties still engaged to optimize building operations and use the building as a Learning Laboratory. The building design achieved U.S. Green Building Council Leadership in Energy and Environmental Design for New Construction (LEED-NC) Gold Certification in 2008 (Figure 2) and a 2008 EPA Energy Star Rating of 96 with design highlights that include: (1) Water use was designed to use 40% less than a typical design baseline. The design included low flow fixtures, waterless urinals and dual flush toilets; (2) Native and adaptive vegetation were selected to minimize the need for irrigation water for landscaping; and (3) Energy use intensity was modeled at 66.1 kBtus/gross square foot, which is 39% better than ASHRAE 90.1 1999. The Wynkoop Building water use (10 gallons/square foot) was measured at lower than industry average (15 gallons/square foot) and GSA goals (13 gallons/square foot), however, it was higher than building management expected it would be. The type of occupants and number of occupants can have a significant impact on fixture water use. The occupancy per floor varied significantly over the study time period, which added uncertainty to the data analysis. Investigation of the fixture use on the 2nd, 5th, and 7th floors identified potential for water use reduction if the flush direction of the dual-flush toilet handles was reversed. The building management retrofitted the building's toilets with handles that operated on reduced flush when pushed down (0.8 gallons) and full flush when pulled up (1.1 gallons). The water pressure on the 5th floor (< 30 psi) is less than half the pressure on the 7th floor (>80 psi). The measured water savings post-retrofit was lower on the 5th floor than the 7th floor. The differences in water pressure may have had an impact on the quantity of water used per floor. The second floor water use was examined prior to and following the toilet fixture retrofit. This floor is where conference rooms for non-building occupants are available for use, thus occupancy is highly variable. The 3-day average volume per flush event was higher post-retrofit (0.79 gallons per event), in contrast to pre-retrofit (0.57 gallons per event). There were 40% more flush events post retrofit, which impacted the findings. Water use in the third floor fitness center was also measured for a limited number of days. Because of water line accessibility, only water use on the men's side of the fitness center was measured and from that the total fitness center water use was estimated. Using the limited data collected, the fitness center shower water use is approximately 2% of the whole building water use. Overall water use in the Wynkoop Building is below the industry baseline and GSA expectations. The dual flush fixture replacement appears to have resulted in additional water savings that are expected to show a savings in the total annual water use.« less

  18. Membrane biological reactors to remove nitrate, digest biosolids, and eliminate water flushing requirements within replicated recirculation systems culturing rainbow trout

    USDA-ARS?s Scientific Manuscript database

    Nutrients, particularly nitrate (NO3), can accumulate to very high levels within low exchange recirculation aquaculture systems (RAS) and negatively impact a number of cultured species. To prevent the harmful effects of nitrate accumulation and to dispose of concentrated waste biosolids, many RAS ar...

  19. On sampling biases arising from insufficient bottle flushing

    NASA Astrophysics Data System (ADS)

    Codispoti, L. A.; Paver, C. R.

    2016-02-01

    Collection of representative water samples using carousel bottles is important for accurately determining biological and chemical gradients. The development of more technologically advanced instrumentation and sampling apparatus causes sampling packages to increase and "soak times" to decrease, increasing the probability that insufficient bottle flushing will produce biased results. Qualitative evidence from various expeditions suggest that insufficient flushing may be a problem. Here we report on multiple field experiments that were conducted to better quantify the errors that can arise from insufficient bottle flushing. Our experiments suggest that soak times of more than 2 minutes are sometimes required to collect a representative sample.

  20. Estuarine turbidity, flushing, salinity, and circulation

    NASA Technical Reports Server (NTRS)

    Pritchard, D. W.

    1972-01-01

    The effects of estuarine turbidity, flushing, salinity, and circulation on the ecology of the Chesapeake Bay are discussed. The sources of fresh water, the variations in salinity, and the circulation patterns created by temperature and salinity changes are analyzed. The application of remote sensors for long term observation of water temperatures is described. The sources of sediment and the biological effects resulting from increased sediments and siltation are identified.

  1. REMEDIATION OF CONTAMINATED SOILS BY SOLVENT FLUSHING

    EPA Science Inventory

    Solvent flushing is a potential technique for remediating a waste disposal/spill site contaminated with organic chemicals. This technique involves the injection of a solvent mixture (e.g., water plus alcohols) that enhances contaminant solubility, reduces the retardation factor, ...

  2. Correspondence between the distribution of hydrodynamic time parameters and the distribution of biological and chemical variables in a semi-enclosed coral reef lagoon

    NASA Astrophysics Data System (ADS)

    Torréton, Jean-Pascal; Rochelle-Newall, Emma; Jouon, Aymeric; Faure, Vincent; Jacquet, Séverine; Douillet, Pascal

    2007-09-01

    Hydrodynamic modeling can be used to spatially characterize water renewal rates in coastal ecosystems. Using a hydrodynamic model implemented over the semi-enclosed Southwest coral lagoon of New Caledonia, a recent study computed the flushing lag as the minimum time required for a particle coming from outside the lagoon (open ocean) to reach a specific station [Jouon, A., Douillet, P., Ouillon, S., Fraunié, P., 2006. Calculations of hydrodynamic time parameters in a semi-opened coastal zone using a 3D hydrodynamic model. Continental Shelf Research 26, 1395-1415]. Local e -flushing time was calculated as the time requested to reach a local grid mesh concentration of 1/e from the precedent step. Here we present an attempt to connect physical forcing to biogeochemical functioning of this coastal ecosystem. An array of stations, located in the lagoonal channel as well as in several bays under anthropogenic influence, was sampled during three cruises. We then tested the statistical relationships between the distribution of flushing indices and those of biological and chemical variables. Among the variables tested, silicate, chlorophyll a and bacterial biomass production present the highest correlations with flushing indices. Correlations are higher with local e-flushing times than with flushing lags or the sum of these two indices. In the bays, these variables often deviate from the relationships determined in the main lagoon channel. In the three bays receiving significant riverine inputs, silicate is well above the regression line, whereas data from the bay receiving almost insignificant freshwater inputs generally fit the lagoon channel regressions. Moreover, in the three bays receiving important urban and industrial effluents, chlorophyll a and bacterial production of biomass generally display values exceeding the lagoon channel regression trends whereas in the bay under moderate anthropogenic influence values follow the regressions obtained in the lagoon channel. The South West lagoon of New Caledonia can hence be viewed as a coastal mesotrophic ecosystem that is flushed by oligotrophic oceanic waters which subsequently replace the lagoonal waters with water considerably impoverished in resources for microbial growth. This flushing was high enough during the periods of study to influence the distribution of phytoplankton biomass, bacterial production of biomass and silicate concentrations in the lagoon channel as well as in some of the bay areas.

  3. Utilization of membranes for H2O recycle system

    NASA Technical Reports Server (NTRS)

    Ohya, H.; Oguchi, M.

    1986-01-01

    Conceptual studies of closed ecological life support systems (CELSS) carried out at NAL in Japan for a water recycle system using membranes are reviewed. The system will treat water from shower room, urine, impure condensation from gas recycle system, and so on. The H2O recycle system is composed of prefilter, ultrafiltration membrane, reverse osmosis membrane, and distillator. Some results are shown for a bullet train of toilet-flushing water recycle equipment with an ultraviltration membrane module. The constant value of the permeation rate with a 4.7 square meters of module is about 70 1/h after 500th of operation. Thermovaporization with porous polytetrafluorocarbon membrane is also proposed to replce the distillator.

  4. Laboratory investigation of flux reduction from dense non-aqueous phase liquid (DNAPL) partial source zone remediation by enhanced dissolution.

    PubMed

    Kaye, Andrew J; Cho, Jaehyun; Basu, Nandita B; Chen, Xiaosong; Annable, Michael D; Jawitz, James W

    2008-11-14

    This study investigated the benefits of partial removal of dense nonaqueous phase liquid (DNAPL) source zones using enhanced dissolution in eight laboratory scale experiments. The benefits were assessed by characterizing the relationship between reductions in DNAPL mass and the corresponding reduction in contaminant mass flux. Four flushing agents were evaluated in eight controlled laboratory experiments to examine the effects of displacement fluid property contrasts and associated override and underride on contaminant flux reduction (R(j)) vs. mass reduction (R(m)) relationships (R(j)(R(m))): 1) 50% ethanol/50% water (less dense than water), 2) 40% ethyl-lactate/60% water (more dense than water), 3) 18% ethanol/26% ethyl-lactate/56% water (neutrally buoyant), and 4) 2% Tween-80 surfactant (also neutrally buoyant). For each DNAPL architecture evaluated, replicate experiments were conducted where source zone dissolution was conducted with a single flushing event to remove most of the DNAPL from the system, and with multiple shorter-duration floods to determine the path of the R(j)(R(m)) relationship. All of the single-flushing experiments exhibited similar R(j)(R(m)) relationships indicating that override and underride effects associated with cosolvents did not significantly affect the remediation performance of the agents. The R(j)(R(m)) relationship of the multiple injection experiments for the cosolvents with a density contrast with water tended to be less desirable in the sense that there was less R(j) for a given R(m). UTCHEM simulations supported the observations from the laboratory experiments and demonstrated the capability of this model to predict R(j)(R(m)) relationships for non-uniformly distributed NAPL sources.

  5. Saline sewage treatment and source separation of urine for more sustainable urban water management.

    PubMed

    Ekama, G A; Wilsenach, J A; Chen, G H

    2011-01-01

    While energy consumption and its associated carbon emission should be minimized in wastewater treatment, it has a much lower priority than human and environmental health, which are both closely related to efficient water quality management. So conservation of surface water quality and quantity are more important for sustainable development than green house gas (GHG) emissions per se. In this paper, two urban water management strategies to conserve fresh water quality and quantity are considered: (1) source separation of urine for improved water quality and (2) saline (e.g. sea) water toilet flushing for reduced fresh water consumption in coastal and mining cities. The former holds promise for simpler and shorter sludge age activated sludge wastewater treatment plants (no nitrification and denitrification), nutrient (Mg, K, P) recovery and improved effluent quality (reduced endocrine disruptor and environmental oestrogen concentrations) and the latter for significantly reduced fresh water consumption, sludge production and oxygen demand (through using anaerobic bioprocesses) and hence energy consumption. Combining source separation of urine and saline water toilet flushing can reduce sewer crown corrosion and reduce effluent P concentrations. To realize the advantages of these two approaches will require significant urban water management changes in that both need dual (fresh and saline) water distribution and (yellow and grey/brown) wastewater collection systems. While considerable work is still required to evaluate these new approaches and quantify their advantages and disadvantages, it would appear that the investment for dual water distribution and wastewater collection systems may be worth making to unlock their benefits for more sustainable urban development.

  6. Regional flow in the Baltic Shield during Holocene coastal regression

    USGS Publications Warehouse

    Voss, Clifford I.; Andersson, Johan

    1993-01-01

    The occurrence of saline waters in the Baltic Shield in Sweden is consistent with ongoing but incomplete Holocene flushing and depends on the geometry and connectivity of conductive structures at both regional and local scales, and on the surface topography. Numerical simulation of regional variable-density fluid flow during Holocene land-rise and coastal regression shows that the existence of any old saline water, whether derived from submarine recharge in regions below Sweden's highest postglacial coastline or geochemical processes in the crystalline rock, is an indication either of slow fluid movements through the bedrock over long times, or of long travel distances through fracture systems before arriving at measurement points. During the land-rise period, regional flow is not affected by the variable density of fluids in the upper few kilometers of the shield, and the topography of the water table is the only driving force. The spatial distribution of meteoric flushing water and pre-Holocene waters may be complex, with the possibility of relatively fresh water in fracture zones below salty units even at depths of a few kilometers. The domination of the topographic driving force implies that deep saline water is not necessarily stagnant, and significant flow may be expected to occur in well-connected horizons even at depth. Local topography variation and fracture zone location combine to create a complex flow field in which local topographic driving forces extend to considerable depth in some areas, whereas regional topographic forces predominate in others. Thus, a pattern may be difficult to discern in measurements of the regional salinity distribution, although it is clear that the coastal region is the major zone of discharge for deeper pre-Holocene fluids. During the land-rise period, the regional flow field equilibrates with changing climatic conditions and coastal positions, while the distribution of flushing water and older water lags and will perpetually change between successive glaciations. These characteristics have direct implications for the safety of nuclear water repositories located at depth in Baltic Shield rocks.

  7. Simulation and video animation of canal flushing created by a tide gate

    USGS Publications Warehouse

    Schoellhamer, David H.

    1988-01-01

    A tide-gate algorithm was added to a one-dimensional unsteady flow model that was calibrated, verified, and used to determine the locations of as many as five tide gates that would maximize flushing in two canal systems. Results from the flow model were used to run a branched Lagrangian transport model to simulate the flushing of a conservative constituent from the canal systems both with and without tide gates. A tide gate produces a part-time riverine flow through the canal system that improves flushing along the flow path created by the tide gate. Flushing with no tide gates and with a single optimally located tide gate are shown with a video animation.

  8. Bacterial community dynamics in surface flow constructed wetlands for the treatment of swine waste

    USDA-ARS?s Scientific Manuscript database

    Constructed wetlands are generally used for the removal of waste from contaminated water. In the swine production system, wastes are traditionally flushed into an anaerobic lagoon which is then sprayed on agricultural fields. However, continuous spraying of lagoon wastewater on fields can lead to hi...

  9. The add-on N-acetylcysteine is more effective than dimethicone alone to eliminate mucus during narrow-band imaging endoscopy: a double-blind, randomized controlled trial.

    PubMed

    Chen, Ming-Jen; Wang, Horng-Yuan; Chang, Chen-Wang; Hu, Kuang-Chun; Hung, Chien-Yuan; Chen, Chih-Jen; Shih, Shou-Chuan

    2013-02-01

    Recent studies have shown that pronase can improve mucosal visibility, but this agent is not uniformly available for human use worldwide. This study aimed to assess the efficacy of N-acetylcysteine (NAC), a mucolytic agent, in improving mucus elimination as measured by decreased endoscopic water flushes during narrow-band imaging (NBI) endoscopy. A consecutive series of patients scheduled for upper gastrointestinal endoscopy at outpatient clinics were enrolled in this double-blind, randomized controlled trial. The control group drank a preparation of 100 mg dimethicone (5 ml at 20 mg/ml) plus water up to 100 ml, and the NAC group drank 300 mg NAC plus 100 mg dimethicone and water up to 100 ml. During the endoscopy, the endoscopist used as many flushes of water as deemed necessary to produce a satisfactory NBI view of the entire gastric mucosa. In all, 177 patients with a mean age of 51 years were evaluated in this study. Significantly lesser water was used for flushing during NBI endoscopy for the NAC group than the control group; 40 ml (30-70, 0-120) versus 50 ml (30-100, 0-150) (median (interquartile range, range), p = 0.0095). Considering the safety profile of NAC, decreasing the number of water flushes for optimal vision and unavailability of pronase in some areas, the authors suggest the use of add-on NAC to eliminate mucus during NBI endoscopy.

  10. From "E-flows" to "Sed-flows": Managing the Problem of Sediment in High Altitude Hydropower Systems

    NASA Astrophysics Data System (ADS)

    Gabbud, C.; Lane, S. N.

    2017-12-01

    The connections between stream hydraulics, geomorphology and ecosystems in mountain rivers have been substantially perturbed by humans, for example through flow regulation related to hydropower activities. It is well known that the ecosystem impacts downstream of hydropower dams may be managed by a properly designed compensation release or environmental flows ("e-flows"), and such flows may also include sediment considerations (e.g. to break up bed armor). However, there has been much less attention given to the ecosystem impacts of water intakes (where water is extracted and transferred for storage and/or power production), even though in many mountain systems such intakes may be prevalent. Flow intakes tend to be smaller than dams and because they fill quickly in the presence of sediment delivery, they often need to be flushed, many times within a day in Alpine glaciated catchments with high sediment yields. The associated short duration "flood" flow is characterised by very high sediment concentrations, which may drastically modify downstream habitat, both during the floods but also due to subsequent accumulation of "legacy" sediment. The impacts on flora and fauna of these systems have not been well studied. In addition, there are no guidelines established that might allow the design of "e-flows" that also treat this sediment problem, something we call "sed-flows". Through an Alpine field example, we quantify the hydrological, geomorphological, and ecosystem impacts of Alpine water transfer systems. The high sediment concentrations of these flushing flows lead to very high rates of channel disturbance downstream, superimposed upon long-term and progressive bed sediment accumulation. Monthly macroinvertebrate surveys over almost a two-year period showed that reductions in the flushing rate reduced rates of disturbance substantially, and led to rapid macroinvertebrate recovery, even in the seasons (autumn and winter) when biological activity should be reduced. The results suggest the need to redesign e-flows to take into account these sediment impacts if the objectives of e-flows are to be realised.

  11. Effect of subdepressor clonidine on flushing reactions in rosacea. Change in malar thermal circulation index during provoked flushing reactions.

    PubMed

    Wilkin, J K

    1983-03-01

    The effects of clonidine hydrochloride, an agent effective in suppressing other types of flushing reactions, were investigated in patients with erythematotelangiectatic rosacea. Clonidine hydrochloride, 0.05 mg, was given orally twice daily for two weeks. Mean arterial BP was not altered during clonidine treatment. Flushing reactions provoked with water at 60 degrees C, red wine, and chocolate were not suppressed during clonidine treatment. Clonidine did lead to malar hypothermia. It may be that any treatment benefit obtained from the reduction in vascular reactivity by clonidine in rosacea is offset by the malar hypothermia.

  12. Comparing catchment hydrologic response to a regional storm using specific conductivity sensors

    USGS Publications Warehouse

    Inserillo, Ashley; Green, Mark B.; Shanley, James B.; Boyer, Joseph

    2017-01-01

    A better understanding of stormwater generation and solute sources is needed to improve the protection of aquatic ecosystems, infrastructure, and human health from large runoff events. Much of our understanding of water and solutes produced during stormflow comes from studies of individual, small headwater catchments. This study compared many different types of catchments during a single large event to help isolate landscape controls on streamwater and solute generation, including human-impacted land cover. We used a distributed network of specific electrical conductivity sensors to trace storm response during the post-tropical cyclone Sandy event of October 2012 at 29 catchments across the state of New Hampshire. A citizen science sensor network, Lotic Volunteer for Temperature, Electrical Conductivity, and Stage, provided a unique opportunity to investigate high-temporal resolution stream behavior at a broad spatial scale. Three storm response metrics were analyzed in this study: (a) fraction of new water contributing to the hydrograph; (b) presence of first flush (mobilization of solutes during the beginning of the rain event); and (c) magnitude of first flush. We compared new water and first flush to 64 predictor attributes related to land cover, soil, topography, and precipitation. The new water fraction was positively correlated with low and medium intensity development in the catchment and riparian buffers and with the precipitation from a rain event 9 days prior to Sandy. The presence of first flush was most closely related (positively) to soil organic matter. Magnitude of first flush was not strongly related to any of the catchment variables. Our results highlight the potentially important role of human landscape modification in runoff generation at multiple spatial scales and the lack of a clear role in solute flushing. Further development of regional-scale in situ sensor networks will provide better understanding of stormflow and solute generation across a wide range of landscape conditions.

  13. Air Embolism During TEVAR: Carbon Dioxide Flushing Decreases the Amount of Gas Released from Thoracic Stent-Grafts During Deployment.

    PubMed

    Rohlffs, Fiona; Tsilimparis, Nikolaos; Saleptsis, Vasilis; Diener, Holger; Debus, E Sebastian; Kölbel, Tilo

    2017-02-01

    To investigate the amount of gas released from Zenith thoracic stent-grafts using standard saline flushing vs the carbon dioxide flushing technique. In an experimental bench setting, 20 thoracic stent-grafts were separated into 2 groups of 10 endografts. One group of grafts was flushed with 60 mL saline and the other group was flushed with carbon dioxide for 5 minutes followed by 60 mL saline. All grafts were deployed into a water-filled container with a curved plastic pipe; the deployment was recorded and released gas was measured using a calibrated setup. Gas was released from all grafts in both study groups during endograft deployment. The average amount of released gas per graft was significantly lower in the study group with carbon dioxide flushing (0.79 vs 0.51 mL, p=0.005). Thoracic endografts release significant amounts of air during deployment if flushed according to the instructions for use. Application of carbon dioxide for the flushing of thoracic stent-grafts prior to standard saline flush significantly reduces the amount of gas released during deployment. The additional use of carbon dioxide should be considered as a standard flush technique for aortic stent-grafts, especially in those implanted in proximal aortic segments, to reduce the risk of air embolism and stroke.

  14. Installation Restoration Program. Phase 2. Confirmation/Quantification. Stage 1. Air Force Plant 38, Porter, New York

    DTIC Science & Technology

    1988-04-01

    drainageways collect surface runoff at the plant and channel the water off plant property. These are: the Central Drain- age Ditch, the Magazine Ditch, and...past, this drain- age system collected test area deluge waters , small spills from test- ing areas, and drainage from around the flush and maintenance...Drain- age Ditch Table 4-2 shows the results of the analyses of two water samples and one soil/sediment sample that were obtained from the drainage from

  15. 21 CFR 870.1210 - Continuous flush catheter.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1210 Continuous flush catheter. (a) Identification. A continuous flush catheter is an attachment to a catheter-transducer system...

  16. 21 CFR 870.1210 - Continuous flush catheter.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1210 Continuous flush catheter. (a) Identification. A continuous flush catheter is an attachment to a catheter-transducer system...

  17. 21 CFR 870.1210 - Continuous flush catheter.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1210 Continuous flush catheter. (a) Identification. A continuous flush catheter is an attachment to a catheter-transducer system...

  18. The impact of an inadequate municipal water system on the residents of Chinhoyi town, Zimbabwe.

    PubMed

    Schwartz, U; Siziya, S; Tshimanga, M; Barduagni, P; Chauke, T L

    1999-06-01

    To assess the use and impact of the water reticulation system in Chinhoyi on its residents. Cross sectional and case series studies. Chinhoyi town. 600 Chinhoyi residents. Practices and perceptions of Chinhoyi residents on the water system, and distribution of water-related diseases per area of residence. Out of 600 respondents, 565 (99.3%) had access to piped water and 558 (98.0%) to flush toilets. Breakdowns of water supply and functioning of toilet facility were reported by 308 (77.0%) and 110 (28.0%) respondents in the previous six months, respectively. Main complaints of Chinhoyi residents were about low water quality (36.2%), inadequate sewage system (31.3%) and environmental pollution (26.5%). Cases of water-related diseases were not associated with natural water bodies. Chinhoyi residents have good access to the municipal water and an adequate sanitation system. However, low quality of the water, frequent system breakdowns and the degradation and loss of amenity of the environment impair their quality of life.

  19. Environmental control and life support - Partially closed system will save big money

    NASA Technical Reports Server (NTRS)

    Guy, W. W.

    1983-01-01

    Although the NASA space station has not yet been completely defined, realistic estimates may be made of the environmental control and life support system requirements entailed by a crew of eight, a resupply interval of 90 days, an initial launch which includes expendables for the first resupply interval, 7.86 lb/day of water per person, etc. An appraisal of these requirements is presented which strongly suggests the utility of a partially closed life support system. Such a scheme would give the crew high quality water to drink, and recycle nonpotable water from hand washing, bathing, clothes and dish washing, and urinal flushing. The excess recovery process water is electrolyzed to provide metabolic and leakage oxygen. The crew would drink electrolysis water and atmospheric humidity control moisture-derived water.

  20. Reduced risk estimations after remediation of lead (Pb) in drinking water at two US school districts.

    PubMed

    Triantafyllidou, Simoni; Le, Trung; Gallagher, Daniel; Edwards, Marc

    2014-01-01

    The risk of students to develop elevated blood lead from drinking water consumption at schools was assessed, which is a different approach from predictions of geometric mean blood lead levels. Measured water lead levels (WLLs) from 63 elementary schools in Seattle and 601 elementary schools in Los Angeles were acquired before and after voluntary remediation of water lead contamination problems. Combined exposures to measured school WLLs (first-draw and flushed, 50% of water consumption) and home WLLs (50% of water consumption) were used as inputs to the Integrated Exposure Uptake Biokinetic (IEUBK) model for each school. In Seattle an average 11.2% of students were predicted to exceed a blood lead threshold of 5 μg/dL across 63 schools pre-remediation, but predicted risks at individual schools varied (7% risk of exceedance at a "low exposure school", 11% risk at a "typical exposure school", and 31% risk at a "high exposure school"). Addition of water filters and removal of lead plumbing lowered school WLL inputs to the model, and reduced the predicted risk output to 4.8% on average for Seattle elementary students across all 63 schools. The remnant post-remediation risk was attributable to other assumed background lead sources in the model (air, soil, dust, diet and home WLLs), with school WLLs practically eliminated as a health threat. Los Angeles schools instead instituted a flushing program which was assumed to eliminate first-draw WLLs as inputs to the model. With assumed benefits of remedial flushing, the predicted average risk of students to exceed a BLL threshold of 5 μg/dL dropped from 8.6% to 6.0% across 601 schools. In an era with increasingly stringent public health goals (e.g., reduction of blood lead safety threshold from 10 to 5 μg/dL), quantifiable health benefits to students were predicted after water lead remediation at two large US school systems. © 2013.

  1. Quantifying the residence time and flushing characteristics of a shallow, back-barrier estuary: Application of hydrodynamic and particle tracking models

    USGS Publications Warehouse

    Defne, Zafer; Ganju, Neil K.

    2015-01-01

    Estuarine residence time is a major driver of eutrophication and water quality. Barnegat Bay-Little Egg Harbor (BB-LEH), New Jersey, is a lagoonal back-barrier estuary that is subject to anthropogenic pressures including nutrient loading, eutrophication, and subsequent declines in water quality. A combination of hydrodynamic and particle tracking modeling was used to identify the mechanisms controlling flushing, residence time, and spatial variability of particle retention. The models demonstrated a pronounced northward subtidal flow from Little Egg Inlet in the south to Pt. Pleasant Canal in the north due to frictional effects in the inlets, leading to better flushing of the southern half of the estuary and particle retention in the northern estuary. Mean residence time for BB-LEH was 13 days but spatial variability was between ∼0 and 30 days depending on the initial particle location. Mean residence time with tidal forcing alone was 24 days (spatial variability between ∼0 and 50 days); the tides were relatively inefficient in flushing the northern end of the Bay. Scenarios with successive exclusion of physical processes from the models revealed that meteorological and remote offshore forcing were stronger drivers of exchange than riverine inflow. Investigations of water quality and eutrophication should take into account spatial variability in hydrodynamics and residence time in order to better quantify the roles of nutrient loading, production, and flushing.

  2. Urine monitoring system failure analysis and operational verification test report

    NASA Technical Reports Server (NTRS)

    Glanfield, E. J.

    1978-01-01

    Failure analysis and testing of a prototype urine monitoring system (UMS) are reported. System performance was characterized by a regression formula developed from volume measurement test data. When the volume measurement test data. When the volume measurement data was imputted to the formula, the standard error of the estimate calculated using the regression formula was found to be within 1.524% of the mean of the mass of the input. System repeatability was found to be somewhat dependent upon the residual volume of the system and the evaporation of fluid from the separator. The evaporation rate was determined to be approximately 1cc/minute. The residual volume in the UMS was determined by measuring the concentration of LiCl in the flush water. Observed results indicated residual levels in the range of 9-10ml, however, results obtained during the flushing efficiency test indicated a residual level of approximately 20ml. It is recommended that the phase separator pumpout time be extended or the design modified to minimize the residual level.

  3. The Role of Flushing Dental Waterlines for the Removal of Microbial Contaminants - MCEARD

    EPA Science Inventory

    Objectives. This study was designed to determine the role of flushing dental water lines for the removal of heterotrophic plate count bacteria, Legionella spp., and free-living protozoa. Methods. Forty dental offices were surveyed in the study. An initial sample and a sample tak...

  4. Environmental Control and Life Support Systems technology options for Space Station application

    NASA Technical Reports Server (NTRS)

    Hall, J. B., Jr.; Ferebee, M. J., Jr.; Sage, K. H.

    1985-01-01

    Continuous assessments regarding the suitability of candidate technologies for manned Space Stations will be needed over the next several years to obtain a basis for recommending the optimum system for an Initial Operating Capability (IOC) Space Station which is to be launched in the early 1990's. This paper has the objective to present analysis programs, the candidate recommendations, and the recommended approach for integration these candidates into the NASA Space Station reference configuration. Attention is given to ECLSS (Environmental Control and Life Support System) technology assessment program, an analysis approach for candidate technology recommendations, mission model variables, a candidate integration program, metabolic oxygen recovery, urine/flush water and all waste water recovery, wash water and condensate water recovery, and an integration analysis.

  5. Combination of an electrolytic pretreatment unit with secondary water reclamation processes

    NASA Technical Reports Server (NTRS)

    Wells, G. W.; Bonura, M. S.

    1973-01-01

    The design and fabrication of a flight concept prototype electrolytic pretreatment unit (EPU) and of a contractor-furnished air evaporation unit (AEU) are described. The integrated EPU and AEU potable water recovery system is referred to as the Electrovap and is capable of processing the urine and flush water of a six-man crew. Results of a five-day performance verification test of the Electrovap system are presented and plans are included for the extended testing of the Electrovap to produce data applicable to the combination of electrolytic pretreatment with most final potable water recovery systems. Plans are also presented for a program to define the design requirements for combining the electrolytic pretreatment unit with a reverse osmosis final processing unit.

  6. Controlled sediment flushing at the Cancano Reservoir (Italian Alps): Management of the operation and downstream environmental impact.

    PubMed

    Espa, Paolo; Brignoli, Maria Laura; Crosa, Giuseppe; Gentili, Gaetano; Quadroni, Silvia

    2016-11-01

    Sediment flushing may be effective to preserve reservoir storage, but concerns arise about sustainability for downstream freshwater ecosystems. We report on the controlled flushing of approximately 110,000 tons of silt from a 120 Mm(3) reservoir on the Adda River, the main tributary of Lake Como, Italy. Technical constraints prevented flushing during high flows, and the operation had to be spread out over three consecutive years (2010-2012) and, for each year, over a rather long time span (40-50 days). To mitigate the downstream impact, the suspended sediment concentration (SSC) of the evacuated water was controlled by regulating the dislodging works inside the reservoir, increasing the streamflow in the regulated tributaries, and operating an instream settling basin. SSC and water flow as well as benthic macroinvertebrates and trout were monitored as far as 28 km below the reservoir. At the most upstream gauging station, SSC peaked up to 100 g/l and ranged from 3.5 to 8 g/l on average per each operation. Stream quality metrics based on macroinvertebrate data evidenced the impairment due to flushing; however, the benthic community showed high resilience, recovering to pre-flushing conditions in 6-9 months. Trout data were biased by stocking and sport fishing and were more difficult to be interpreted. The trout population wouldn't seem remarkably altered, even if a non-negligible impact could be deduced through pre/post-event sample comparison. Copyright © 2016. Published by Elsevier Ltd.

  7. Variability of mercury concentrations in domestic well water, New Jersey Coastal Plain

    USGS Publications Warehouse

    Szabo, Zoltan; Barringer, Julia L.; Jacobsen, Eric; Smith, Nicholas P; Gallagher, Robert A; Sites, Andrew

    2010-01-01

    Concentrations of total (unfiltered) mercury (Hg) exceed the Maximum Contaminant Level (2 µg/L) in the acidic water withdrawn by more than 700 domestic wells from the areally extensive unconfined Kirkwood-Cohansey aquifer system. Background concentrations of Hg generally are <0.01 µg/L. The source of the Hg contamination has been hypothesized to arise from Hg of pesticide-application, atmospheric, and geologic origin being mobilized by some component(s) of septic-system effluent or urban leachates in unsewered residential areas. Initial results at many affected wells were not reproducible upon later resampling despite rigorous quality assurance, prompting concerns that duration of well flushing could affect the Hg concentrations. A cooperative study by the U.S. Geological Survey and the New Jersey Department of Environmental Protection examined variability in Hg results during the flushing of domestic wells. Samples were collected at regular intervals (about 10 minutes) during flushing for eight domestic wells, until stabilization criteria was met for field-measured parameters; the Hg concentrations in the final samples ranged from about 0.0005 to 11 µg/L. Unfiltered Hg concentrations in samples collected during purging varied slightly, but particulate Hg concentration (unfiltered – filtered (0.45 micron capsule) concentration) typically was highly variable for each well, with no consistent pattern of increase or decrease in concentration. Surges of particulates probably were associated with pump cycling. Pre-pumping samples from the holding tanks generally had the lowest Hg concentrations among the samples collected at the well that day. Comparing the newly obtained results at each well to results from previous sampling indicated that Hg concentrations in water from the Hg-contaminated areas were generally greater among samples collected on different dates (long-term variations, months to years) than among samples collected on the same day (short-term variations, minutes to hours). The long-term variations likely are caused by changes in local pumping regimes and time-varying capture of slugs of Hg-contaminated water moving on flowpaths.

  8. Experimental Demonstration of 3-Dimensional Flow Structures and Depositional Features in a Lateral Recirculation Zone

    NASA Astrophysics Data System (ADS)

    Grams, P. E.; Schmeeckle, M. W.; Mueller, E. R.; Buscombe, D.; Kasprak, A.; Leary, K. P.

    2016-12-01

    The connections between stream hydraulics, geomorphology and ecosystems in mountain rivers have been substantially perturbed by humans, for example through flow regulation related to hydropower activities. It is well known that the ecosystem impacts downstream of hydropower dams may be managed by a properly designed compensation release or environmental flows ("e-flows"), and such flows may also include sediment considerations (e.g. to break up bed armor). However, there has been much less attention given to the ecosystem impacts of water intakes (where water is extracted and transferred for storage and/or power production), even though in many mountain systems such intakes may be prevalent. Flow intakes tend to be smaller than dams and because they fill quickly in the presence of sediment delivery, they often need to be flushed, many times within a day in Alpine glaciated catchments with high sediment yields. The associated short duration "flood" flow is characterised by very high sediment concentrations, which may drastically modify downstream habitat, both during the floods but also due to subsequent accumulation of "legacy" sediment. The impacts on flora and fauna of these systems have not been well studied. In addition, there are no guidelines established that might allow the design of "e-flows" that also treat this sediment problem, something we call "sed-flows". Through an Alpine field example, we quantify the hydrological, geomorphological, and ecosystem impacts of Alpine water transfer systems. The high sediment concentrations of these flushing flows lead to very high rates of channel disturbance downstream, superimposed upon long-term and progressive bed sediment accumulation. Monthly macroinvertebrate surveys over almost a two-year period showed that reductions in the flushing rate reduced rates of disturbance substantially, and led to rapid macroinvertebrate recovery, even in the seasons (autumn and winter) when biological activity should be reduced. The results suggest the need to redesign e-flows to take into account these sediment impacts if the objectives of e-flows are to be realised.

  9. Status of ISS Water Management and Recovery

    NASA Technical Reports Server (NTRS)

    Carter, Layne; Wilson, Laura Labuda; Orozco, Nicole

    2012-01-01

    Water management on ISS is responsible for the provision of water to the crew for drinking water, food preparation, and hygiene, to the Oxygen Generation System (OGS) for oxygen production via electrolysis, to the Waste & Hygiene Compartment (WHC) for flush water, and for experiments on ISS. This paper summarizes water management activities on the ISS US Segment, and provides a status of the performance and issues related to the operation of the Water Processor Assembly (WPA) and Urine Processor Assembly (UPA). This paper summarizes the on-orbit status as of May 2011, and describes the technical challenges encountered and lessons learned over the past year.

  10. Status of ISS Water Management and Recovery

    NASA Technical Reports Server (NTRS)

    Carter, Layne; Pruitt, Jennifer; Brown, Christopher A.; Bazley, Jesse; Gazda, Daniel; Schaezler, Ryan; Bankers, Lyndsey

    2016-01-01

    Water management on ISS is responsible for the provision of water to the crew for drinking water, food preparation, and hygiene, to the Oxygen Generation System (OGS) for oxygen production via electrolysis, to the Waste & Hygiene Compartment (WHC) for flush water, and for experiments on ISS. This paper summarizes water management activities on the ISS US Segment and provides a status of the performance and issues related to the operation of the Water Processor Assembly (WPA) and Urine Processor Assembly (UPA). This paper summarizes the on-orbit status as of May 2016 and describes the technical challenges encountered and lessons learned over the past year.

  11. Status of ISS Water Management and Recovery

    NASA Technical Reports Server (NTRS)

    Carter, Layne; Brown, Christopher; Orozco, Nicole

    2014-01-01

    Water management on ISS is responsible for the provision of water to the crew for drinking water, food preparation, and hygiene, to the Oxygen Generation System (OGS) for oxygen production via electrolysis, to the Waste & Hygiene Compartment (WHC) for flush water, and for experiments on ISS. This paper summarizes water management activities on the ISS US Segment, and provides a status of the performance and issues related to the operation of the Water Processor Assembly (WPA) and Urine Processor Assembly (UPA). This paper summarizes the on-orbit status as of June 2013, and describes the technical challenges encountered and lessons learned over the past year.

  12. Status of ISS Water Management and Recovery

    NASA Technical Reports Server (NTRS)

    Carter, Layne; Tobias, Barry; Orozco, Nicole

    2012-01-01

    Water management on ISS is responsible for the provision of water to the crew for drinking water, food preparation, and hygiene, to the Oxygen Generation System (OGS) for oxygen production via electrolysis, to the Waste & Hygiene Compartment (WHC) for flush water, and for experiments on ISS. This paper summarizes water management activities on the ISS US Segment, and provides a status of the performance and issues related to the operation of the Water Processor Assembly (WPA) and Urine Processor Assembly (UPA). This paper summarizes the on-orbit status as of June 2012, and describes the technical challenges encountered and lessons learned over the past year.

  13. Status of ISS Water Management and Recovery

    NASA Technical Reports Server (NTRS)

    Carter, Layne; Takada, Kevin; Gazda, Daniel; Brown, Christopher; Bazley, Jesse; Schaezler, Ryan; Bankers, Lyndsey

    2017-01-01

    Water management on ISS is responsible for the provision of water to the crew for drinking water, food preparation, and hygiene, to the Oxygen Generation System (OGS) for oxygen production via electrolysis, to the Waste & Hygiene Compartment (WHC) for flush water, and for experiments on ISS. This paper summarizes water management activities on the ISS US Segment and provides a status of the performance and issues related to the operation of the Water Processor Assembly (WPA) and Urine Processor Assembly (UPA). This paper summarizes the on-orbit status as of June 2017 and describes the technical challenges encountered and lessons learned over the past year.

  14. Status of ISS Water Management and Recovery

    NASA Technical Reports Server (NTRS)

    Carter, Layne; Pruitt, Jennifer; Brown, Christopher A.; Schaezler, Ryan; Bankers, Lyndsey

    2015-01-01

    Water management on ISS is responsible for the provision of water to the crew for drinking water, food preparation, and hygiene, to the Oxygen Generation System (OGS) for oxygen production via electrolysis, to the Waste & Hygiene Compartment (WHC) for flush water, and for experiments on ISS. This paper summarizes water management activities on the ISS US Segment, and provides a status of the performance and issues related to the operation of the Water Processor Assembly (WPA) and Urine Processor Assembly (UPA). This paper summarizes the on-orbit status as of May 2015 and describes the technical challenges encountered and lessons learned over the past two years.

  15. A rainwater harvesting system reliability model based on nonparametric stochastic rainfall generator

    NASA Astrophysics Data System (ADS)

    Basinger, Matt; Montalto, Franco; Lall, Upmanu

    2010-10-01

    SummaryThe reliability with which harvested rainwater can be used as a means of flushing toilets, irrigating gardens, and topping off air-conditioner serving multifamily residential buildings in New York City is assessed using a new rainwater harvesting (RWH) system reliability model. Although demonstrated with a specific case study, the model is portable because it is based on a nonparametric rainfall generation procedure utilizing a bootstrapped markov chain. Precipitation occurrence is simulated using transition probabilities derived for each day of the year based on the historical probability of wet and dry day state changes. Precipitation amounts are selected from a matrix of historical values within a moving 15 day window that is centered on the target day. RWH system reliability is determined for user-specified catchment area and tank volume ranges using precipitation ensembles generated using the described stochastic procedure. The reliability with which NYC backyard gardens can be irrigated and air conditioning units supplied with water harvested from local roofs exceeds 80% and 90%, respectively, for the entire range of catchment areas and tank volumes considered in the analysis. For RWH systems installed on the most commonly occurring rooftop catchment areas found in NYC (51-75 m 2), toilet flushing demand can be met with 7-40% reliability, with lower end of the range representing buildings with high flow toilets and no storage elements, and the upper end representing buildings that feature low flow fixtures and storage tanks of up to 5 m 3. When the reliability curves developed are used to size RWH systems to flush the low flow toilets of all multifamily buildings found a typical residential neighborhood in the Bronx, rooftop runoff inputs to the sewer system are reduced by approximately 28% over an average rainfall year, and potable water demand is reduced by approximately 53%.

  16. Effects of flow diversions on water and habitat quality: Examples from California's highly manipulated Sacramento–San Joaquin Delta

    USGS Publications Warehouse

    Monsen, Nancy E.; Cloern, James E.; Burau, Jon R.

    2007-01-01

    We use selected monitoring data to illustrate how localized water diversions from seasonal barriers, gate operations, and export pumps alter water quality across the Sacramento-San Joaquin Delta (California). Dynamics of water-quality variability are complex because the Delta is a mixing zone of water from the Sacramento and San Joaquin Rivers, agricultural return water, and the San Francisco Estuary. Each source has distinct water-quality characteristics, and the contribution of each source varies in response to natural hydrologic variability and water diversions. We use simulations with a tidal hydrodynamic model to reveal how three diversion events, as case studies, influence water quality through their alteration of Delta-wide water circulation patterns and flushing time. Reduction of export pumping decreases the proportion of Sacramento- to San Joaquin-derived fresh water in the central Delta, leading to rapid increases in salinity. Delta Cross Channel gate operations control salinity in the western Delta and alter the freshwater source distribution in the central Delta. Removal of the head of Old River barrier, in autumn, increases the flushing time of the Stockton Ship Channel from days to weeks, contributing to a depletion of dissolved oxygen. Each shift in water quality has implications either for habitat quality or municipal drinking water, illustrating the importance of a systems view to anticipate the suite of changes induced by flow manipulations, and to minimize the conflicts inherent in allocations of scarce resources to meet multiple objectives.

  17. Method and device for disinfecting a toilet bowl

    DOEpatents

    Almon, A.C.

    1997-03-18

    Method and device are disclosed for disinfecting a flush toilet. The device is an electrolytic cell mounted in the tank of the toilet, with two wire mesh electrodes immersed in the water in the tank and a battery applying approximately one to two volts of electric potential to the electrodes so that they chemically reduce a portion of the water in the tank to hydrogen peroxide. Then, when the tank is flushed, the peroxide is carried into the bowl where it can kill bacteria. 2 figs.

  18. Method and device for disinfecting a toilet bowl

    DOEpatents

    Almon, Amy C.

    1997-01-01

    Method and device for disinfecting a flush toilet. The device is an electrocell mounted in the tank of the toilet, with two wire mesh electrodes immersed in the water in the tank and a battery applying approximately one to two volts of electric potential to the electrodes so that they chemically reduce a portion of the water in the tank to hydrogen peroxide. Then, when the tank is flushed, the peroxide is carried into the bowl where it can kill bacteria.

  19. Modelling the far field hydro-environmental impacts of tidal farms - A focus on tidal regime, inter-tidal zones and flushing

    NASA Astrophysics Data System (ADS)

    Nash, S.; O'Brien, N.; Olbert, A.; Hartnett, M.

    2014-10-01

    The introduction of tidal stream turbines into water bodies can have an impact on the environment due to changes in the hydrodynamic flow fields resulting from the extraction of energy by the tidal turbines. Water levels, tidal currents and flushing characteristics could potentially be significantly altered with the introduction of tidal turbine farms, which could lead to possible loss of habitat and a change in the tidal regime. Therefore, planning of tidal turbines field deployments must take into account possible hydro-environmental impacts. This paper describes research undertaken by the authors in the Shannon Estuary to predict changes in the tidal regime and flushing characteristics, with the introduction of tidal turbine farms of different array configurations. The model was simulated using a 2D hydrodynamic model that was modified to incorporate the effects of tidal turbine fields. Water levels are shown to have been affected with the inclusion of turbines, especially in areas upstream of the turbine farm where inter-tidal zones could become predominately inundated resulting in loss of habitat in the estuary. Flushing parameters were also shown to be altered with the inclusion of turbines, with residence time shown to be increased, which could change pollutant transport in the region.

  20. Design, Monitoring, and Validation of a High Performance Sustainable Building

    DTIC Science & Technology

    2013-08-01

    normalized by building average population and square footage. Longstreet had a larger number of emergency calls than CESS, but the ESTCP team did not have...system was measured sUSEPArately from the domestic water use. The rainwater was used to displace potable water for toilet flushing and vehicle washing...ApprovedOMB No. 0704-0188 Public reporting burden for the collection of information is estimated to average 1 hour per response, including the time for

  1. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jensenius, J.; Munksgaard, N.C.

    Fracture filling calcite from the piercement fields of East Rosa, Skjold, Rolf, North Arne, Nils and Vagn and the dome field Dan have been studied by fluorescence and cathodoluminescence microscopy, fluid inclusion microthermometry and carbon and oxygen isotopes. The carbon and oxygen isotope compositions of the reservoir matrix chalk have also been measured. The temperature estimates obtained from fluid inclusion data suggest that the fracture filling calcite of the piercement fields precipitated during hot water flushing of the reservoirs. The flushing system only existed around the salt diapirs and was probably related to expulsion of overpressured fluid from the surroundingmore » sediments. The thermal anomaly and the faults associated with the diapirs probably were important factors in focusing the ascending water. Lower {delta}{sup 18}O values with shallower depth of burial suggest that the porosity of chalk in the shallower fields was more severely reduced by calcite cementation during the flushing event than in the deeper fields. In the case of North Arne, Nils, Vagn and Dan, {delta}{sup 13}C values of the fracture filling calcites are similar to those of normal chalk (0.5 to 3.5 {per thousand}). However, calcites from Rolf, Skjold and East Rosa are depleted by {minus}1.8, {minus}6.2 and {minus}16.7 {per thousand}, respectively. Only in East Rosa is the matrix chalk itself depleted in {sup 13}C. The low {delta}{sup 13}C values are interpreted as the result of biodegradation. Sulfate originating from the underlying diapirs was flushed into the reservoir and used by bacteria to degrade present hydrocarbons. This process produced {sup 13}c depleted bicarbonate which was incorporated into the fracture-filling calcites.« less

  2. Fluorescence Sensors for Early Detection of Nitrification in Drinking Water Distribution Systems - Interference Corrections and Feasibility Assessment

    NASA Astrophysics Data System (ADS)

    Do, T. D.; Pifer, A.; Chowdhury, Z.; Wahman, D.; Zhang, W.; Fairey, J.

    2017-12-01

    Detection of nitrification events in chloraminated drinking water distribution systems remains an ongoing challenge for many drinking water utilities, including Dallas Water Utilities (DWU) and the City of Houston (CoH). Each year, these utilities experience nitrification events that necessitate extensive flushing, resulting in the loss of billions of gallons of finished water. Biological techniques used to quantify the activity of nitrifying bacteria are impractical for real-time monitoring because they require significant laboratory efforts and/or lengthy incubation times. At present, DWU and CoH regularly rely on physicochemical parameters including total chlorine and monochloramine residual, and free ammonia, nitrite, and nitrate as indicators of nitrification, but these metrics lack specificity to nitrifying bacteria. To improve detection of nitrification in chloraminated drinking water distribution systems, we seek to develop a real-time fluorescence-based sensor system to detect the early onset of nitrification events by measuring the fluorescence of soluble microbial products (SMPs) specific to nitrifying bacteria. Preliminary data indicates that fluorescence-based metrics have the sensitivity to detect these SMPs in the early stages of nitrification, but several remaining challenges will be explored in this presentation. We will focus on benchtop and sensor results from ongoing batch and annular reactor experiments designed to (1) identify fluorescence wavelength pairs and data processing techniques suitable for measurement of SMPs from nitrification and (2) assess and correct potential interferences, such as those from monochloramine, pH, iron, nitrite, nitrate and humic substances. This work will serve as the basis for developing fluorescence sensor packages for full-scale testing and validation in the DWU and CoH systems. Findings from this research could be leveraged to identify nitrification events in their early stages, facilitating proactive interventions and decreasing the severity and frequency of nitrification episodes and water loss due to flushing.

  3. A comment on the use of flushing time, residence time, and age as transport time scales

    USGS Publications Warehouse

    Monsen, N.E.; Cloern, J.E.; Lucas, L.V.; Monismith, Stephen G.

    2002-01-01

    Applications of transport time scales are pervasive in biological, hydrologic, and geochemical studies yet these times scales are not consistently defined and applied with rigor in the literature. We compare three transport time scales (flushing time, age, and residence time) commonly used to measure the retention of water or scalar quantities transported with water. We identify the underlying assumptions associated with each time scale, describe procedures for computing these time scales in idealized cases, and identify pitfalls when real-world systems deviate from these idealizations. We then apply the time scale definitions to a shallow 378 ha tidal lake to illustrate how deviations between real water bodies and the idealized examples can result from: (1) non-steady flow; (2) spatial variability in bathymetry, circulation, and transport time scales; and (3) tides that introduce complexities not accounted for in the idealized cases. These examples illustrate that no single transport time scale is valid for all time periods, locations, and constituents, and no one time scale describes all transport processes. We encourage aquatic scientists to rigorously define the transport time scale when it is applied, identify the underlying assumptions in the application of that concept, and ask if those assumptions are valid in the application of that approach for computing transport time scales in real systems.

  4. Skin decontamination: principles and perspectives.

    PubMed

    Chan, Heidi P; Zhai, Hongbo; Hui, Xiaoying; Maibach, Howard I

    2013-11-01

    Skin decontamination is the primary intervention needed in chemical, biological and radiological exposures, involving immediate removal of the contaminant from the skin performed in the most efficient way. The most readily available decontamination system on a practical basis is washing with soap and water or water only. Timely use of flushing with copious amounts of water may physically remove the contaminant. However, this traditional method may not be completely effective, and contaminants left on the skin after traditional washing procedures can have toxic consequences. This article focuses on the principles and practices of skin decontamination.

  5. Theory, construction and operation of simple tensiometers.

    USGS Publications Warehouse

    Stannard, D.I.

    1986-01-01

    The tensiometer presented here in detail is suited to diverse on-site applications. Constructed from readily available, inexpensive parts, it can measure as much as 0.85 bar of tension. Design features include a flushing system for removal of entrapped air or mercury, and an easily maintained modular network of nylon manometers and water-supply tubes. -from Author

  6. Sensitivity of Pumping Energy on the Life Cycle Impacts of a Commercial Rainwater Harvesting System

    EPA Science Inventory

    assessed using a functional unit of 1 m3 of rainwater and municipal water delivery for flushing toilets and urinals in a four story-commercial building in DC. We collect primary data on CRWH including designs and amount of materials from the ARCSA partners and compile the life cy...

  7. Indoor Noise Loading in Residential Prefabricated Buildings

    NASA Astrophysics Data System (ADS)

    Kraus, Michal; Juhásová Šenitková, Ingrid

    2017-10-01

    Quality on indoor environment is among others also defined by an acoustic comfort and noise emissions. The indoor noise loading in the residential prefabricated buildings is specific problem related to structural design of these buildings. Problems with noise level of sanitary systems are mostly associated with hydraulic shock such as water distribution and sewage drainage. Another very common cause of excessive noise is also flushing the toilet or water fall on enamelled steel (bath or shower). This paper aims to analyse the acoustic properties in the residential prefabricated buildings. Sanitary core of the assessed apartment is in original condition without any alterations. The sanitary core is based on a formica (high-pressure laminate). The study discusses the maximum sound levels in the three assessed rooms for the three different noise sources. The values of maximum noise level are measured for the corridor, bedroom and living room. Sources of noise are common activities relating to the operation of sanitary core - the toilet flush in the toilet, falling water from the shower in the bathroom and the water falling on the bottom of the kitchen sink in the kitchen. Other sources of noise are eliminated or minimized during the experiment. The digital sound level meter Testo 815 is used for measurements. The measured values of maximum sound level LA,max [dB] are adjusted by the correction coefficient. The obtained values are compared with the hygienic limits for day and night period. Night hygienic limit (30 dB) is exceeded in all the rooms for all noise sources. This limit is exceeded from 17 to 73%. The values in the bedroom and the living room meet the daily hygienic limit (40 dB). The daily limit is exceeded only in the corridor. The highest values of noise are identified for the toilet flushing.

  8. Modulation of magmatic processes by CO2 flushing

    NASA Astrophysics Data System (ADS)

    Caricchi, Luca; Sheldrake, Tom E.; Blundy, Jon

    2018-06-01

    Magmatic systems are the engines driving volcanic eruptions and the source of fluids responsible for the formation of porphyry-type ore deposits. Sudden variations of pressure, temperature and volume in magmatic systems can produce unrest, which may culminate in a volcanic eruption and/or the abrupt release of ore-forming fluids. Such variations of the conditions within magmatic systems are commonly ascribed to the injection of new magma from depth. However, as magmas fractionating at depth or rising to the upper crust release CO2-rich fluids, the interaction between carbonic fluids and H2O-rich magmas stored in the upper crust (CO2 flushing), must also be a common process affecting the evolution of subvolcanic magma reservoirs. Here, we investigate the effect of gas injection on the stability and chemical evolution of magmatic systems. We calculate the chemical and physical evolution of magmas subjected to CO2-flushing using rhyolite-MELTS. We compare the calculations with a set of melt inclusion data for Mt. St. Helens, Merapi, Etna, and Stromboli volcanoes. We provide an approach that can be used to distinguish between melt inclusions trapped during CO2 flushing, magma ascent and decompression, or those affected by post-entrapment H2O-loss. Our results show that CO2 flushing is a widespread process in both felsic and mafic magmatic systems. Depending upon initial magma crystallinity and duration of CO2 input, flushing can either lead to volcanic eruption or fluid release. We suggest that CO2 flushing is a fundamental process modulating the behaviour and chemical evolution of crustal magmatic systems.

  9. First flush characteristics of rainfall runoff from a paddy field in the Taihu Lake watershed, China.

    PubMed

    Li, Songmin; Wang, Xiaoling; Qiao, Bin; Li, Jiansheng; Tu, Jiamin

    2017-03-01

    Nonpoint storm runoff remains a major threat to surface water quality in China. As a paddy matures, numerous fertilizers are needed, especially in the rainy seasons; the concentration of nitrogen and phosphorus in rainfall runoff from farmland is much higher than at other times, and this poses a great threat to water bodies and is the main reason for water eutrophication, especially in high concentration drainages. To date, most studies regarding the characteristics of pollutants in rainfall runoff have mainly been concentrated on urban runoff and watershed runoff; therefore, it is particularly important to investigate the characteristics of nitrogen and phosphorus loss in rainfall runoff from paddy fields. To study the characteristics of nitrogen and phosphorus loss and whether the first flush effect exists, continuous monitoring of the rainfall runoff process of six rainfall events was conducted in 2013, of which four rainfall events during storm, high, middle, and low intensity rainfalls were analyzed, and runoff and quality parameters, such as suspended solids (SS), total nitrogen (TN), ammonium nitrogen (NH 4 + -N), nitrate nitrogen (NO 3 - -N), total phosphorus (TP), and phosphate (PO 4 3- -P), were analyzed to determine the relationship between runoff and water quality. The paddy field is located north of Wuxi Lake Basin along the Hejia River upstream in Zhoutie town, Yixing city. An analysis of the load distribution during rainfall runoff was conducted. Event mean concentration (EMC) was used to evaluate the pollution situation of the paddy field's rainfall runoff. A curve of the dimensionless normalized cumulative load (L) vs. normalized cumulative flow (F) (L-F curve), the probability of the mass first flush (MFFn), and the pollutants carried by the initial 25% of runoff (FF 25 ) were used to analyze the first flush effect of the paddy field runoff, and different contaminants show different results: the concentration of nitrogen and phosphorus fluctuate and follow a similar trend as runoff changes, NO 3 - -N concentration is lower in the early part of runoff and higher in the later, and TP mainly occurs in the particle state in storm runoff and mainly in the dissolved state when the rainfall intensity is smaller. Nitrogen and phosphorus losses from paddy fields are closely related to the average rainfall intensity and the max rainfall intensity, and the runoff loss of nitrogen and phosphorus is more severe when the rainfall intensity is large. Based on an analysis of multiple methodologies, TN and NH 4 + -N show a certain degree of a first flush effect, whereas the first flush effect of TP is not obvious. The first flush effect of SS is obvious in larger intensity rainfall and shows a slight secondary flush effect in smaller rainfall events.

  10. The impact of recreational boat traffic on Marbled Murrelets (Brachyramphus marmoratus).

    PubMed

    Bellefleur, Danielle; Lee, Philip; Ronconi, Robert A

    2009-01-01

    This study evaluated the impact of small boat traffic on reaction distances of Marbled Murrelets (Brachyramphus marmoratus), in the marine waters of Pacific Rim National Park Reserve, British Columbia, Canada. Observers on moving boats recorded the minimum distance the boat came to murrelets on the water, and any disturbance reaction (fly, dive, no reaction). Out of the 7500 interactions 11.7% flew, 30.8% dove and 58.1% exhibited no flushing reaction. Using a product-limit analysis, we developed curves for the proportion of Marbled Murrelets flushing (dive or flight) as a function of reaction distance. Overall, the majority of Marbled Murrelets waited until boats were within 40 m before reacting, with 25% of the population reacting at 29.2m. A stepwise Cox regression indicated that age, boat speed, and boat density (loaded in that order), significantly affected flushing response. More juveniles flushed than adults (70.1 versus 51.7%), but at closer distances. Faster boats caused a greater proportion of birds to flush, and at further distances (25% of birds flushed at 40 m at speeds > 29 kph versus 28m at speeds <12kph). A stepwise logistic regression on diving and flight responses indicated that birds tended to fly completely out of feeding areas at the approach of boats travelling >28.8 kph and later in the season (July and August). Other secondary variables included; boat density and time of day. Discussion focused on possible management actions such as the application of speed limits, set back distances, and exclusion of boat traffic to protect Marbled Murrelets.

  11. Overnight stagnation of drinking water in household taps induces microbial growth and changes in community composition.

    PubMed

    Lautenschlager, Karin; Boon, Nico; Wang, Yingying; Egli, Thomas; Hammes, Frederik

    2010-09-01

    Drinking water quality is routinely monitored in the distribution network but not inside households at the point of consumption. Fluctuating temperatures, residence times (stagnation), pipe materials and decreasing pipe diameters can promote bacterial growth in buildings. To test the influence of stagnation in households on the bacterial cell concentrations and composition, water was sampled from 10 separate households after overnight stagnation and after flushing the taps. Cell concentrations, measured by flow cytometry, increased (2-3-fold) in all water samples after stagnation. This increase was also observed in adenosine tri-phosphate (ATP) concentrations (2-18-fold) and heterotrophic plate counts (4-580-fold). An observed increase in cell biovolume and ATP-per-cell concentrations furthermore suggests that the increase in cell concentrations was due to microbial growth. After 5 min flushing of the taps, cell concentrations and water temperature decreased to the level generally found in the drinking water network. Denaturing gradient gel electrophoresis also showed a change in the microbial composition after stagnation. This study showed that water stagnation in household pipes results in considerable microbial changes. While hygienic risk was not directly assessed, it emphasizes the need for the development of good material validation methods, recommendations and spot tests for in-house water installations. However, a simple mitigation strategy would be a short flushing of taps prior to use. Copyright © 2010 Elsevier Ltd. All rights reserved.

  12. Contamination of hospital tap water: the survival and persistence of Pseudomonas aeruginosa on conventional and 'antimicrobial' outlet fittings.

    PubMed

    Hutchins, C F; Moore, G; Thompson, K-A; Webb, J; Walker, J T

    2017-10-01

    Pseudomonas aeruginosa infections have been linked to contaminated hospital taps, highlighting the potential for tap outlet fittings (OF) to harbour biofilm. P. aeruginosa may be transferred to OFs via contaminated cleaning cloths. Suggested interventions include flushing regimens and alternative OF designs. To investigate the transfer of P. aeruginosa from a contaminated cleaning cloth to conventional and 'antimicrobial/antibiofilm' OFs and to determine whether this contamination persists and/or leads to contamination of tap water. Microfibre cloths contaminated with P. aeruginosa (10 8  cfu/mL) were used to wipe four different types of OF [one of conventional design (OF-A) and three marketed as 'antimicrobial' and/or 'antibiofilm' (OF- B, -C and -D)]. OFs were inserted into an experimental water distribution system for up to 24 h. Survival was assessed by culture. Single and multiple water samples were collected and cultured for P. aeruginosa. The median number of P. aeruginosa transferred from cloth to OF was 5.7 × 10 5  cfu (OF-A), 1.9 × 10 6  cfu (OF-B), 1.4 × 10 5  cfu (OF-C) and 2.9 × 10 6  cfu (OF-D). Numbers declined on all OFs during the 24 h period with log reductions ranging from 3.5 (OF-C) to 5.2 (OF-B; P > 0.05). All water samples delivered immediately after OF contamination contained P. aeruginosa at ≥10 cfu per 100 mL. Contamination of water delivered from OF-A persisted despite continued flushing. Water delivered from OF-B did not contain P. aeruginosa beyond the first flush. Contaminated cleaning cloths may transfer P. aeruginosa to OFs, leading to contamination of tap water. Although not removing the potential for contamination, 'antimicrobial/antibiofilm' OFs may prevent P. aeruginosa from continually contaminating water delivered from the outlet. Copyright © 2017 The Healthcare Infection Society. All rights reserved.

  13. Randomized, open trial comparing a modified double-lumen needle follicular flushing system with a single-lumen aspiration needle in IVF patients with poor ovarian response.

    PubMed

    von Horn, Kyra; Depenbusch, Marion; Schultze-Mosgau, Askan; Griesinger, Georg

    2017-04-01

    Is a modified double-lumen aspiration needle system with follicular flushing able to increase the mean oocyte yield by at least one in poor response IVF patients as compared to single-lumen needle aspiration without flushing? Follicular flushing with the modified flushing system did not increase the number of oocytes, but increased the procedure duration. Most studies on follicular flushing were performed with conventional double-lumen needles in patients who were normal responders. Overall, these studies indicated no benefit of follicular flushing. Prospective, single-centre, randomized, controlled, open, superiority trial comparing the 17 G Steiner-Tan Needle® flushing system with a standard 17 G single-lumen aspiration needle (Gynetics®); time frame February 2015-March 2016. Eighty IVF patients, 18-45 years, BMI >18 kg/m2 to <35 kg/m2, presenting with ≤ five follicles >10 mm in both ovaries at the end of the follicular phase were randomized to either aspirating and flushing each follicle 3× with the Steiner-Tan-Needle® automated flushing system (n = 40) or a conventional single-lumen needle aspiration (n = 40). Primary outcome was the number of cumulus-oocyte-complexes (COCs). Procedure duration, burden (Depression Anxiety and Stress Scale; DASS-21) and post-procedure pain were also assessed. Flushing was not superior with a mean (SD) number of COCs of 2.4 (2.0) and 3.1 (2.3) in the Steiner-Tan Needle® and in the Gynectics® group, respectively (mean difference -0.7, 95% CI: 0.3 to -1.6; P = 0.27). Likewise no differences were observed in metaphase II  oocytes, two pronuclear oocytes, number of patients having an embryo transfer and DASS 21 scores. The procedure duration was significantly 2-fold increased. Testing for differences in the number of patients achieving an embryo transfer or differences in pregnancy rate would require a much larger sample size. The use of follicular flushing is unlikely to benefit the prognosis of patients with poor ovarian response. The Steiner-Tan Needles® and the flushing system were provided for free by the manufacturer. K.v.H. has received personal fees from Finox and non-financial support from Merck-Serono; M.D. has received personal fees from Finox and non-financial support from Merck-Serono. A.S.-M. has received personal fees and non-financial support from M.D., Ferring, Merck-Serono, Finox, TEVA. G.G. has received personal fees and non-financial support from M.D., Ferring, Merck-Serono, Finox, TEVA, IBSA, Glycotope, as well as personal fees from VitroLife, NMC Healthcare LLC, ReprodWissen LLC and ZIVA LLC. NCT 02365350 (clinicaltrials.gov). Sixth of February 2015. Ninth of February 2015. © The Author 2017. Published by Oxford University Press on behalf of the European Society of Human Reproduction and Embryology. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  14. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Maienschein, J.L.; Garcia, F.; Garza, R.G.

    Tritium-handling apparatus has been decontaminated as part of the downsizing of the LLNL Tritium Facility. Two stainless-steel glove boxes that had been used to process lithium deuteride-tritide (LiDT) slat were decontaminated using the Portable Cleanup System so that they could be flushed with room air through the facility ventilation system. In this paper the details on the decontamination operation are provided. A series of metal (palladium and vanadium) hydride storage beds have been drained of tritium and flushed with deuterium, in order to remove as much tritium as possible. The bed draining and flushing procedure is described, and a calculationalmore » method is presented which allows estimation of the tritium remaining in a bed after it has been drained and flushed. Data on specific bed draining and flushing are given.« less

  15. Burbank performs Part 1 of the WRS-1 Repair

    NASA Image and Video Library

    2012-03-08

    ISS030-E-128752 (8 March 2012) --- NASA astronaut Dan Burbank, Expedition 30 commander, performs part one of the Water Recovery System-1 (WRS-1) repair in the Tranquility node of the International Space Station. Burbank removed and replaced the failed Catalytic Reactor (CR), and installed a temporary filter kit between the new CR and the Microbial Check Valve (MCV) to support a system flush of the new Orbital Replacement Unit (ORU).

  16. Wind tunnel investigation of an all flush orifice air data system for a large subsonic aircraft. [conducted in a Langley 8 foot transonic pressure tunnel

    NASA Technical Reports Server (NTRS)

    Larson, T. J.; Flechner, S. G.; Siemers, P. M., III

    1980-01-01

    The results of a wind tunnel investigation on an all flush orifice air data system for use on a KC-135A aircraft are presented. The investigation was performed to determine the applicability of fixed all flush orifice air data systems that use only aircraft surfaces for orifices on the nose of the model (in a configuration similar to that of the shuttle entry air data system) provided the measurements required for the determination of stagnation pressure, angle of attack, and angle of sideslip. For the measurement of static pressure, additional flush orifices in positions on the sides of the fuselage corresponding to those in a standard pitot-static system were required. An acceptable but less accurate system, consisting of orifices only on the nose of the model, is defined and discussed.

  17. Column Testing and 1D Reactive Transport Modeling to Evaluate Uranium Plume Persistence Processes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Johnson, Raymond H.; Morrison, Stan; Morris, Sarah

    Motivation for Study: Natural flushing of contaminants at various U.S. Department of Energy Office of Legacy Management sites is not proceeding as quickly as predicted (plume persistence) Objectives: Help determine natural flushing rates using column tests. Use 1D reactive transport modeling to better understand the major processes that are creating plume persistence Approach: Core samples from under a former mill tailings area Tailings have been removed. Column leaching using lab-prepared water similar to nearby Gunnison River water. 1D reactive transport modeling to evaluate processes

  18. Modelling the effects of on-site greywater reuse and low flush toilets on municipal sewer systems.

    PubMed

    Penn, R; Schütze, M; Friedler, E

    2013-01-15

    On-site greywater reuse (GWR) and installation of water-efficient toilets (WET) reduce urban freshwater demand. Research on GWR and WET has generally overlooked the effects that GWR may have on municipal sewer systems. This paper discusses and quantifies these effects. The effects of GWR and WET, positive and negative, were studied by modelling a representative urban sewer system. GWR scenarios were modelled and analysed using the SIMBA simulation system. The results show that, as expected, the flow, velocity and proportional depth decrease as GWR increases. Nevertheless, the reduction is not evenly distributed throughout the day but mainly occurs during the morning and evening peaks. Examination of the effects of reduced toilet flush volumes revealed that in some of the GWR scenarios flows, velocities and proportional depths in the sewer were reduced, while in other GWR scenarios discharge volumes, velocities and proportional depths did not change. Further, it is indicated that as a result of GWR and installation of WET, sewer blockage rates are not expected to increase significantly. The results support the option to construct new sewer systems with smaller pipe diameters. The analysis shows that as the penetration of GWR systems increase, and with the installation of WET, concentrations of pollutants also increase. In GWR scenarios (when toilet flush volume is not reduced) the increase in pollutant concentrations is lower than the proportional reduction of sewage flow. Moreover, the results show that the spatial distribution of houses reusing GW does not significantly affect the parameters examined. Copyright © 2012 Elsevier Ltd. All rights reserved.

  19. SNL-EFDC Simulations of Tidal Turbine-Related Changes to Hydrodynamics and Flushing

    NASA Astrophysics Data System (ADS)

    Roberts, J. D.; Johnson, E.; James, S. C.; Barco, J.; Jones, C.

    2012-12-01

    The marine and hydrokinetic (MHK) industry in the United States faces challenges associated with siting, permitting, construction, and operation of pilot- and full-scale facilities that must be addressed to accelerate environmentally sound deployment of these renewable energy technologies. Little is known about the potential effects of MHK device operation in coastal areas, estuaries, or rivers, or of the cumulative impacts of these devices on aquatic ecosystems. This lack of knowledge affects the actions of regulatory agencies, the opinions of stakeholder groups, and the commitment of energy project developers and investors. Two particularly important factors that can be used as a precursor for MHK-driven environmental changes in estuaries are the effect of decreased tidal range and flushing. For example, tidal-range changes could affect wetland systems that are only wetted under the highest of tides. Significant changes in tidal range could completely change the character of the wetlands through long-term drying. Changes to flushing must also be understood, especially when municipal wastewater and other pollutant sources are discharged into a bay. When MHK operation alters flow rates, decreased flushing of an embayment could yield increased residence times, decreased nutrient and contaminant dispersion, and even the possibility of algal blooms. Small changes to the flow could manifest as noticeable changes to sediment transport and water quality. This work provides example assessments of changes to the physical environment (i.e. currents, tidal ranges, water age, and e-folding time) potentially imposed by the operation of MHK turbine arrays in marine estuary environments using the modeling platform SNL-EFDC. Comparing model results with and without an MHK array facilitates an understanding of how an array of turbines might alter the environment. By using models to simulate water circulation, commensurate changes in water quality, benthic habitat quality, and aquatic food webs may be predicted. Scenarios may be developed that examine the limits of environmental changes that could occur in specific aquatic areas before unacceptable environmental degradation occurs. These simulations and scenario analyses can provide cost-effective planning tools for use before proceeding to detailed siting, engineering designs, and deployment of devices. The results of the models also imply that no single metric is suitable for determining the impact an array of MHK devices will have on a system and additional system-specific metrics should be included for a complete analysis. While it will be left to regulators and environmentalists to determine what degree of environmental changes are acceptable, or if an alternate design, array layout, or decreased power generation capacity is warranted, SNL-EFDC provides a tool developers and regulators can reference to determine the impact MHK devices will have on a site-by-site basis.

  20. Water footbath, automatic flushing, and disinfection to improve the health of bovine feet.

    PubMed

    Fjeldaas, T; Knappe-Poindecker, M; Bøe, K E; Larssen, R B

    2014-05-01

    Disinfecting footbaths are used to treat and prevent interdigital dermatitis (ID) and heel horn erosion (HHE). However, many disinfectants are disadvantageous for the environment and, as an alternative, washing of the feet has been introduced. Our aim was to investigate the effect of water footbaths (trial 1), footbaths with CuSO4 (trial 2), automatic water flushing (trial 3), and water flushing followed by disinfection with a glutaraldehyde-based compound (trial 4) in 4 randomized controlled clinical trials performed in a freestall dairy herd of approximately 45 Norwegian Red cows. At trimming before and after each trial, hind foot diseases, hardness of the claw horn (in D-units), locomotion, and cleanliness of the claws were recorded. Before each trial, the cows were divided in comparable study and control groups, based on prevalence of ID and HHE, parity, and days in milk. Using a transponder-regulated gate, the study groups were led through a footbath (trials 1 and 2) or an automatic washer (trials 3 and 4), whereas the control groups were left untreated. Each trial lasted 3 mo and the curative effect in diseased cows and the preventive effect in cows with healthy feet on ID, HHE, and ID + HHE were analyzed. In trial 2, a preventive effect of CuSO4 on HHE compared with the untreated cows was observed. During trial 1, 100% (11/11) of the treated cows with ID got better and 22% (2/9) without ID became diseased, whereas 92% (11/12) of the treated cows with ID + HHE got better and 38% (3/8) without ID + HHE became diseased. During trial 2, 69% (9/13) of the treated cows with ID got better and 11% (1/9) without ID became diseased. During trial 4, 19% (3/16) of the untreated cows with ID + HHE got better and 71% (5/7) without ID + HHE became diseased. In trial 3, no significant effects on ID, HHE, or ID + HHE were revealed. In trial 2 (CuSO4), the treated cows' claw horn was harder after the trial compared with the controls (D-unit difference: 13.25). In trial 3 (stationary water flushing) the treated cows' claw horn was softer after the trial when compared with the controls (D-unit difference: -15.66). The CuSO4 footbaths were useful to prevent HHE and indicate that automatic stationary flushing with only water had no beneficial effect on ID or HHE. The claw horn of cows walking through CuSO4 became harder and the claw horn of cows that had their hind feet flushed with water became softer compared with the controls. Copyright © 2014 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  1. Dissolved Organic Matter Compositional Change and Biolability During Two Storm Runoff Events in a Small Agricultural Watershed

    NASA Astrophysics Data System (ADS)

    Eckard, Robert S.; Pellerin, Brian A.; Bergamaschi, Brian A.; Bachand, Philip A. M.; Bachand, Sandra M.; Spencer, Robert G. M.; Hernes, Peter J.

    2017-10-01

    Agricultural watersheds are globally pervasive, supporting fundamentally different organic matter source, composition, and concentration profiles in comparison to natural systems. Similar to natural systems, agricultural storm runoff exports large amounts of organic carbon from agricultural land into waterways. But intense management of upper soil layers, waterway channelization, wetland and riparian habitat removal, and postharvest vegetation removal promise to uniquely drive organic matter release to waterways. During a winter first flush and a subsequent storm event, this study investigated the influence of a small agricultural watershed on dissolved organic matter (DOM) source, composition, and biolability. Storm water discharge released strongly terrestrial yet biolabile (23 to 32%) dissolved organic carbon (DOC). Following a 21 day bioassay, a parallel factor analysis identified an 80% reduction in a protein-like (phenylpropyl) component (C2) that was previously correlated to lignin phenol concentration, and a 10% reduction in a humic-like, terrestrially sourced component (C4). Storm-driven releases tripled DOC concentration (from 2.8 to 8.7 mg L-1) during the first flush event in comparison to base flow and were terrestrially sourced, with an eightfold increase in vascular plant derived lignin phenols (23.0 to 185 μg L-1). As inferred from system hydrology, lignin composition, and nitrate as a groundwater tracer, an initial pulse of dilute water from the upstream watershed caused a counterclockwise DOC hysteresis loop. DOC concentrations peaked after 3.5 days, with the delay between peak discharge and peak DOC attributed to storm water hydrology and a period of initial water repellency of agricultural soils, which delayed DOM leaching.

  2. Upgrading and extended testing of the MSC integrated water and waste management hardware

    NASA Technical Reports Server (NTRS)

    Bambenek, R. A.; Nuccio, P. P.; Hurley, T. L.; Jasionowski, W. J.

    1972-01-01

    The results are presented of upgrading and testing an integrated water and waste management system, which uses the compression distillation, reverse osmosis, adsorption filtration and ion-exchange processes to recover potable water from urine, flush water and used wash water. Also included is the development of techniques for extending the useful biological life of biological filters, activated carbon filters and ion-exchange resins to at least 30 days, and presterilizing ion-exchange resins so that sterile water can be recovered from waste water. A wide variety of reverse osmosos materials, surfactants and germicides were experimentally evaluated to determine the best combination for a wash water subsystem. Full-scale module tests with real wash water demonstrated that surface fouling is a major problem.

  3. Microfluidic Device for Sequential Injection and Flushing of Solutions and its Application to Immunosensing

    NASA Astrophysics Data System (ADS)

    Nashida, Norihiro; Suzuki, Hiroaki

    A microfluidic system with injecting and flushing functions was developed. In the system, hydrophilic flow channels have a dry-film photoresist layer which facilitates the introduction of solutions from four injection ports. The injection and flushing of solutions are controlled by valves operated by electrowetting. The valves consist of gold working electrodes in the flow channels or a through-hole in the glass substrate. Solutions can be sequentially introduced through the injection ports into a reaction chamber and flushed through a valve in the through-hole. Necessary immunoassay steps can be conducted on the chip, and a target antibody can be detected electrochemically.

  4. Composting toilets as a sustainable alternative to urban sanitation – A review

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Anand, Chirjiv K., E-mail: chirjiv@gmail.com; Apul, Defne S., E-mail: defne.apul@utoledo.edu

    2014-02-15

    Highlights: • Composting toilets can be an alternative to flush based sanitation. • Many different composting toilet designs are available. • Composting is affected by moisture content, temperature, carbon to nitrogen ratio. • There are many barriers to composting toilets. • Research is needed in science based design of composting toilets. - Abstract: In today’s flush based urban sanitation systems, toilets are connected to both the centralized water and wastewater infrastructures. This approach is not a sustainable use of our water and energy resources. In addition, in the U.S., there is a shortfall in funding for maintenance and upgrade ofmore » the water and wastewater infrastructures. The goal of this paper was to review the current knowledge on composting toilets since this technology is decentralized, requires no water, creates a value product (fertilizer) and can possibly reduce the burden on the current infrastructure as a sustainable sanitation approach. We found a large variety of composting toilet designs and categorized the different types of toilets as being self contained or central; single or multi chamber; waterless or with water/foam flush, electric or non-electric, and no-mix or combined collection. Factors reported as affecting the composting process and their optimum values were identified as; aeration, moisture content (50–60%), temperature (40–65 °C), carbon to nitrogen ratio (25–35), pH (5.5–8.0), and porosity (35–50%). Mass and energy balance models have been created for the composting process. However there is a literature gap in the use of this knowledge in design and operation of composting toilets. To evaluate the stability and safety of compost for use as fertilizer, various methods are available and the temperature–time criterion approach is the most common one used. There are many barriers to the use of composting toilets in urban settings including public acceptance, regulations, and lack of knowledge and experience in composting toilet design and operation and program operation.« less

  5. Root growth dynamics linked to above-ground growth in walnut (Juglans regia).

    PubMed

    Contador, Maria Loreto; Comas, Louise H; Metcalf, Samuel G; Stewart, William L; Porris Gomez, Ignacio; Negron, Claudia; Lampinen, Bruce D

    2015-07-01

    Examination of plant growth below ground is relatively scant compared with that above ground, and is needed to understand whole-plant responses to the environment. This study examines whether the seasonal timing of fine root growth and the spatial distribution of this growth through the soil profile varies in response to canopy manipulation and soil temperature. Plasticity in the seasonal timing and vertical distribution of root production in response to canopy and soil water manipulation was analysed in field-grown walnut (Juglans regia 'Chandler') using minirhizotron techniques. Root production in walnuts followed a unimodal curve, with one marked flush of root growth starting in mid-May, with a peak in mid-June. Root production declined later in the season, corresponding to increased soil temperature, as well as to the period of major carbohydrate allocation to reproduction. Canopy and soil moisture manipulation did not influence the timing of root production, but did influence the vertical distribution of roots through the soil profile. Water deficit appeared to promote root production in deeper soil layers for mining soil water. Canopy removal appeared to promote shallow root production. The findings of this study add to growing evidence that root growth in many ecosystems follows a unimodal curve with one marked flush of root growth in coordination with the initial leaf flush of the season. Root vertical distribution appeared to have greater plasticity than timing of root production in this system, with temperature and/or carbohydrate competition constraining the timing of root growth. Effects on root distribution can have serious impacts on trees, with shallow rooting having negative impacts in years with limited soil water or positive impacts in years with wet springs, and deep rooting having positive impacts on soil water mining from deeper soil layers but negative impacts in years with wet springs. © The Author 2015. Published by Oxford University Press on behalf of the Annals of Botany Company. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  6. Response Characteristics of Dissolved Organic Carbon Flushing in a Subarctic Alpine Catchment

    NASA Astrophysics Data System (ADS)

    Carey, S. K.

    2002-12-01

    Dissolved organic carbon (DOC) is an important part of ecosystem-scale carbon balances and in the transport of contaminants as it interacts with other dissolved substances including trace metals. It also can be used as a surrogate hydrological tracer in permafrost regions as near-surface waters are often DOC enriched due to the presence of thick organic soils. In a small subarctic alpine catchment within the Wolf Creek Research Basin, Yukon, Canada, DOC was studied in the summer of 2001 and spring of 2002 to determine the role frost (both permanent and seasonal), snowmelt and summer storms on DOC flushing. Peak DOC concentrations occurred during the snowmelt period, approximately one week prior to peak discharge. However, peak discharge took place several weeks after snow on south facing exposures had melted. Within the hillslopes, DOC concentrations were three to five times greater in wells underlain with permafrost compared with seasonal frost. Groundwater DOC concentrations declined during snowmelt, yet remained at levels above the streamflow. After peaking, streamflow DOC concentrations declined exponentially suggesting a simple flushing mechanism, however there did not appear to be a relation between DOC and topographic position. Following melt, permafrost underlain slopes had near-surface water tables and retained elevated levels of DOC, whereas slopes without permafrost had rapidly declining water tables at upslope locations with low DOC concentrations at all positions except near-stream riparian zones. The influence of summer rainstorms on DOC was monitored on three occasions. In each case DOC peaked on the ascending limb of the runoff hydrograph and declined exponentially on the receding limb and hysteretic behavior occurred between discharge and DOC during all events. Patterns of DOC within the hillslopes and streams suggest that runoff from permafrost-underlain slopes control DOC flushing within the stream during both snowmelt and summer periods. This flushing mechanism conforms with conceptual models of runoff generation in discontinuous permafrost catchments whereby water tables within permafrost-underlain slopes rise into porous organic-layers, whereupon DOC is leached into the water and rapidly conveyed to the stream.

  7. Water Reuse and Pathogen Tracking

    EPA Science Inventory

    Building product water. By designing our buildings to collect and treat water generated on-site, can be and reused for flushing our toilets and irrigating our landscaping. Several water sources are generated with-in a building including: rainwater, stormwater, graywater, blackwa...

  8. Automatic Vacuum Flushing Technology for Combined Sewer Solids: Laboratory Testing and Proposed Improvements (WERF Report INFR7SG09)

    EPA Science Inventory

    This research study included an extensive literature review on existing sewer sediment flushing technologies. An innovative vacuum flush system previously developed by the U.S. EPA was tested under laboratory conditions. The tests revealed a strong correlation between the strengt...

  9. Characterizations of the first flush in storm water runoff from an urban roadway.

    PubMed

    Lee, B C; Matsui, S; Shimizu, Y; Matsuda, T

    2005-07-01

    Storm water runoff from urban roadways contains anthropogenic pollutants, which are mainly generated from traffic-related activities. The purpose of this study was to evaluate the characteristics of pollutants from the roadway runoff as well as first flush effects. Storm water runoff was sampled during five storm events from the experimental site in Otsu, Shiga, Japan. From the hydrographs and pollutographs for the roadway runoff, the concentration of pollutants increased with increasing runoff flow in the low flow rate event, but did not significantly increase in the high flow rate event. Moreover, according to the analysis of cumulative pollutant mass versus runoff volume curves from five storm events, the first 50% of the runoff volume transported 62% of TOC and Mo, 60% of SS, 59% of Fe, Mn and Cu, 58% of Ni, 57% of Cd and Pb, 56% of Al, 55% of Zn, and 54% of Cr, as the mean values. The first 30% and 80% of the runoff volume also transported 34-43% mass of the pollutants and 82-88% mass of the pollutants, respectively. This study for storm water runoff may also provide useful information to correctly design treatment facilities, such as detention tanks and ponds, filtration and adsorption systems.

  10. Modeling of the Inter-phase Mass Transfer during Cosolvent-Enhanced NAPL Remediation

    NASA Astrophysics Data System (ADS)

    Agaoglu, B.; Scheytt, T. J.; Copty, N. K.

    2012-12-01

    This study investigates the factors influencing inter-phase mass transfer during cosolvent-enhanced NAPL remediation and the ability of the REV (Representative Elementary Volume) modeling approach to simulate these processes. The NAPLs considered in this study consist of pure toluene, pure benzene and known mixtures of these two compounds, while ethanol-water mixtures were selected as the remedial flushing solutions. Batch tests were performed to identify both the equilibrium and non-equilibrium properties of the multiphase system. A series of column flushing experiments involving different NAPLs were conducted for different ethanol contents in the flushing solution and for different operational parameters. Experimental results were compared to numerical simulations obtained with the UTCHEM multiphase flow simulator (Delshad et al., 1996). Results indicate that the velocity of the flushing solution is a major parameter influencing the inter-phase mass transport processes at the pore scale. Depending on the NAPL composition and porous medium properties, the remedial solution may follow preferential flow paths and be subject to reduced contact with the NAPL. This leads to a steep decrease in the apparent mass transfer coefficient. Correlations of the apparent time-dependent mass transfer coefficient as a function of flushing velocity are developed for various porous media. Experimental results also show that the NAPL mass transfer coefficient into the cosolvent solution increases when the NAPL phase becomes mobile. This is attributed to the increase in pore scale contact area between NAPL and the remedial solution when NAPL mobilization occurs. These results suggest the need to define a temporal and spatially variable mass transfer coefficient of the NAPL into the cosolvent solution to reflect the occurrence of subscale preferential flow paths and the transient bypassing of the NAPL mass. The implications of these findings on field scale NAPL remediation with cosolvents are discussed.

  11. Production flush of Agaricus blazei on Brazilian casing layers

    PubMed Central

    Colauto, Nelson Barros; da Silveira, Adriano Reis; da Eira, Augusto Ferreira; Linde, Giani Andrea

    2011-01-01

    This study aimed to verify the biological efficiency and production flushes of Agaricus blazei strains on different casing layers during 90 cultivation days. Four casing layers were used: mixture of subsoil and charcoal (VCS), lime schist (LSC), São Paulo peat (SPP) and Santa Catarina peat (SCP); and two genetically distant A. blazei strains. The fungus was grown in composted substratum and, after total colonization, a pasteurized casing layer was added over the substratum, and fructification was induced. Mushrooms were picked up daily when the basidiocarp veil was stretched, but before the lamella were exposed. The biological efficiency (BE) was determined by the fresh basidiocarp mass divided by the substratum dry mass, expressed in percentage. The production flushes were also determined over time production. The BE and production flushes during 90 days were affected by the strains as well as by the casing layers. The ABL26 and LSC produced the best BE of 60.4%. Although VCS is the most used casing layer in Brazil, it is inferior to other casing layers, for all strains, throughout cultivation time. The strain, not the casing layer, is responsible for eventual variations of the average mushroom mass. In average, circa 50% of the mushroom production occurs around the first month, 30% in the second month, and 20% in third month. The casing layer water management depends on the casing layer type and the strain. Production flush responds better to water reposition, mainly with ABL26, and better porosity to LSC and SCP casing layers. PMID:24031673

  12. Design and the parametric testing of the space station prototype integrated vapor compression distillation water recovery module

    NASA Technical Reports Server (NTRS)

    Reveley, W. F.; Nuccio, P. P.

    1975-01-01

    Potable water for the Space Station Prototype life support system is generated by the vapor compression technique of vacuum distillation. A description of a complete three-man modular vapor compression water renovation loop that was built and tested is presented; included are all of the pumps, tankage, chemical post-treatment, instrumentation, and controls necessary to make the loop representative of an automatic, self-monitoring, null gravity system. The design rationale is given and the evolved configuration is described. Presented next are the results of an extensive parametric test during which distilled water was generated from urine and urinal flush water with concentration of solids in the evaporating liquid increasing progressively to 60 percent. Water quality, quantity and production rate are shown together with measured energy consumption rate in terms of watt-hours per kilogram of distilled water produced.

  13. Zero Nuisance Piggeries: long-term performance of MBR (membrane bioreactor) for dilute swine wastewater treatment using submerged membrane bioreactor in semi-industrial scale.

    PubMed

    Prado, Nolwenn; Ochoa, Juan; Amrane, Abdeltif

    2009-04-01

    Effective aerobic/anoxic treatment of piggery manure wastewater was achieved in a real farm scale using a small piggery (72 pigs) with reuse of the treated water. The experimental procedure was followed for 9 months. Fresh manure (FM) is formed by daily flush on piggeries and biologically treated after centrifuge pre-treatment. For upgrade liquid/solid separation and pathogen retention in biological treatment, a membrane system was used with the aim of effluent reuse in flush. Despite an evolution of FM through time, centrifuge pre-treatment and bioreactor performances stayed at high level. An elimination of 86% of the suspended solids occurred through pre-treatment, and nitrogen and COD biological degradation remains at 90% all time long. Moreover, interestingly about half of the soluble part of phosphorus (20% of the global phosphorus content) was biologically removed via the recirculation between the anoxic and the aerobic tank which acted as an intermittent aerobic/anoxic sequence. A part of COD was proved not biodegradable and was accumulated via the reuse of the treated water for flushing purpose. This accumulation justifies washing of the biomass between two runs in purpose to enhance the treated water quality and also to meet the membrane tolerance. The membrane was proved reliable as far as the maintenance procedure was respected. Maintenance cleaning had to be operated as soon as the TransMembrane Pressure (TMP) achieved 50 mbar and curative washing was necessary if the TMP increased over 90 mbar or between 2 runs. The temperature was proved to influence both the bioactivity and the membrane fouling kinetic. Finally, it was demonstrated that the process was sustainable for long-term management of swine wastewater at semi-industrial scale.

  14. Development and recovery from winter embolism in silver birch: seasonal patterns and relationships with the phenological cycle in oceanic Scotland.

    PubMed

    Strati, Sara; Patiño, Sandra; Slidders, Caley; Cundall, Edward P; Mencuccini, Maurizio

    2003-07-01

    Silver birch (Betula pendula Roth) is increasingly used in the United Kingdom for reforestation. However, recent evidence indicates that, under some circumstances, planted birch can suffer serious and repeated mortality of the apical leaders and branches, with consequent loss of apical dominance and the formation of a contorted stem. Plants from 37 seed sources of silver birch from Scotland and northern England planted at two sites were compared for several characteristics related to hydraulic architecture, vulnerability to freeze-thaw cycle induced embolism and spring recovery from winter embolism during the period 2000-2002. Phenological rhythms were also monitored in late winter-early spring to document relationships between phenology and water relations parameters. Significant differences were found across seed sources in stage of bud flushing for four dates in spring. Early flushing seed sources differed by about 1 to 2 weeks from late-flushing seed sources across the two sites. Wintertime xylem embolism in stems reached a peak of about 50 to 70% loss of xylem hydraulic conductivity, depending on the size and position of the sample shoots in the canopy. Small apical shoots were significantly more embolized than large basal shoots. Development of winter embolism was coupled to the occurrence of frost events. As percent loss of hydraulic conductivity increased during the winter, wood relative water content declined. Embolism reversal occurred rapidly in spring at the time of development of positive root pressure. No significant differences in the degree of winter embolism in 2001 were found among the three seed sources examined. The investigation was expanded in the winter-spring of 2002 to include 10 seed sources across both sites. Significant differences were found in degree of winter embolism across sites, dates and seed sources. For each date, there was a significant relationship between flushing scores and wood relative water contents across the two sites and all seed sources, suggesting that differences in time of flushing across sites and seed sources were likely caused by differences in the time of occurrence of root pressure, a necessary precondition to flushing.

  15. Etiologies and management of cutaneous flushing: Nonmalignant causes.

    PubMed

    Sadeghian, Azeen; Rouhana, Hailey; Oswald-Stumpf, Brittany; Boh, Erin

    2017-09-01

    The flushing phenomenon may represent a physiologic or a pathologic reaction. Although flushing is usually benign, it is prudent that the physician remains aware of potentially life-threatening conditions associated with cutaneous flushing. A thorough investigation should be performed if the flushing is atypical or not clearly associated with a benign underlying process. The diagnosis often relies on a pertinent history, review of systems, physical examination, and various laboratory and imaging modalities, all of which are discussed in the 2 articles in this continuing medical education series. This article reviews flushing associated with fever, hyperthermia, emotions, menopause, medications, alcohol, food, hypersensitivity reactions, rosacea, hyperthyroidism, dumping syndrome, superior vena cava syndrome, and neurologic etiologies. Copyright © 2016 American Academy of Dermatology, Inc. Published by Elsevier Inc. All rights reserved.

  16. Straight Flush

    ERIC Educational Resources Information Center

    Allen, Jim

    2006-01-01

    When there's less rainfall, communities often restrict water use to conserve water. But as the U.S. population expands into more arid, drought-stricken areas, the increasing demand for water can stress water districts even in years that see average water supplies. As such, education facilities, which use large amounts of water, are placed under…

  17. The chemical/physical and microbiological characteristics of typical bath and laundry waste waters. [waste water reclamation during manned space flight

    NASA Technical Reports Server (NTRS)

    Hypes, W. D.; Batten, C. E.; Wilkins, J. R.

    1974-01-01

    Chemical/physical and microbiological characteristics are studied of typical bath and laundry waters collected during a 12 day test in which the untreated waste waters were reused for toilet flush. Most significant changes were found for ammonia, color, methylene blue active substances, phosphates, sodium, sulfates, total organic carbon, total solids, and turbidity in comparison with tap water baseline. The mean total number of microorganisms detected in the waste waters ranged from 1 million to 10 to the 7th power cells/m1 and the mean number of possible coliforms ranged from 10 to the 5th power to 1 million. An accumulation of particulates and an objectible odor were detected in the tankage used during the 12 day reuse of the untreated waste waters. The combined bath and laundry waste waters from a family of four provided 91 percent of the toilet flush water for the same family.

  18. Microbial Health Risks Associated with Exposure to Stormwater in a Water Plaza

    NASA Astrophysics Data System (ADS)

    Sales-Ortells, Helena; Medema, Gertjan

    2015-04-01

    Climate change scenarios predict an increase of intense rainfall events in summer in Western Europe. Current urban drainage systems cannot cope with such intense precipitation events. Cities are constructing local stormwater storage facilities to prevent pluvial flooding. Combining storage with other functions, such as recreation, may lead to exposure to contaminants. This study assessed the microbial quality of rainwater collected in a water plaza in Rotterdam (The Netherlands) and the health risks associated with recreational exposure. The water plaza collects street run-off, diverges first flush to the sewer system and stores the rest of the run-off in the plaza as open water. A rain simulation experiment was conducted using drinking water from fire hydrants. The water flowed over the street pavement into the street gutters and into the square. Samples were collected from the first flush diverted water and from two different levels of the water plaza at different points in time. Campylobacter spp., Cryptosporidium, and Legionella pneumophila were the pathogens investigated, using quantitative PCR. Escherichia coli was quantified with culture methods to obtain information on faecal contamination. Microbial source tracking tools (human Bacteroides, avian Helicobacter and canine mitochondrial DNA, all analysed with quantitative PCR) were used to determine the origin (human, animal) of the intestinal pathogens. To estimate the health risks for children playing in the water plaza after a rain event, a quantitative microbial risk assessment model was built. The volume of water ingested was obtained from literature on similar locations (flooded streets). Published dose-response models were used to calculate the risk per event. Exposure frequency was estimated using weather data (precipitation events). E. coli concentrations were below the level for excellent bathing water in the EU Bathing Water Directive. Cryptosporidium was not found in any sample. Campylobacter spp. was found in all samples, with higher concentrations in samples that contained human Bacteroides than in samples with contamination from birds and dogs (15 vs 3.7 gc (genomic copies)/100mL). In both cases, the estimated disease risk associated with Campylobacter and recreational exposure to the water plaza were higher than the Dutch national incidence. This indicates that the health risk associated with recreational exposure to the water plaza is significant. L. pneumophila was found only in two out of ten pond samples. Legionnaire's disease risks were lower than the Dutch national incidence. However,higher health risks are expected in the future because of increased frequency of rain events. Presence of human Bacteroides indicates possible cross-connections with the combined sewer system that should be identified and removed to reduce the gastrointestinal disease risks. Other measures include cleaning/disinfection of the water plaza after extreme precipitation; increasing the capacity of the first flush pump; regular cleaning of the catchment area and gutters; informing the neighbours of the importance of keeping the streets clean of pets depositions; and informing the public about the health risks derived from recreational uses of the water plaza after rain events. Finally, monitoring the water quality during real rain events is recommended to better characterize the health risks.

  19. Ballast Water Treatment, U.S. Great Lakes Bulk Carrier Engineering and Cost Study. Volume 2: Analysis of On-Board Treatment Methods, Alternative Ballast Water Management Practices, and Implementation Costs

    DTIC Science & Technology

    2013-11-01

    flushing filter, disinfection with injected chlorine dioxide (chlorine dioxide is generated onboard from two component chemicals, sulfuric acid...Management System 400 80 250-8000 (10000) Sulfuric Acid and Purate for ClO2 generation Yes 0.005-0.028 8-18 Decreased sediment, potential corrosion...feed chemicals, Purate and sulfuric acid. 5. Operational and Maintenance Cost: Estimated operating and maintenance cost is $80/1000 m3 of ballast

  20. Characteristics of the overflow pollution of storm drains with inappropriate sewage entry.

    PubMed

    Yin, Hailong; Lu, Yi; Xu, Zuxin; Li, Huaizheng; Schwegler, Benedict R

    2017-02-01

    To probe the overflow pollution of separate storm drains with inappropriate sewage entries, in terms of the relationship between sewage entries and the corresponding dry-weather and wet-weather overflow, the monitoring activities were conducted in a storm drainage system in the Shanghai downtown area (374 ha). In this study site, samples from inappropriately entered dry-weather sewage and the overflow due to storm pumps operation on dry-weather and wet-weather days were collected and then monitored for six water quality constituents. It was found that overflow concentrations of dry-weather period could be higher than those of wet-weather period; under wet-weather period, the overflow concentrations of storm drains were close to or even higher than that of combined sewers. Relatively strong first flush mostly occurred under heavy rain that satisfied critical rainfall amount, maximum rainfall intensity, and maximum pumping discharge, while almost no first flush effect or only weak first flush effect was found for the other rainfall events. Such phenomenon was attributed to lower in-line pipe storage as compared to that of the combined sewers, and serious sediment accumulation within the storm pipes due to sewage entry. For this kind of system, treating a continuous overflow rate is a better strategy than treating the maximum amount of early part of the overflow. Correcting the key inappropriate sewage entries into storm drains should also be focused.

  1. Development and application of EEAST: a life cycle based model for use of harvested rainwater and composting toilets in buildings.

    PubMed

    Devkota, J; Schlachter, H; Anand, C; Phillips, R; Apul, Defne

    2013-11-30

    Harvested rainwater systems and composting toilets are expected to be an important part of sustainable solutions in buildings. Yet, to this date, a model evaluating their economic and environmental impact has been missing. To address this need, a life cycle based model, EEAST was developed. EEAST was designed to compare the business as usual (BAU) case of using potable water for toilet flushing and irrigation to alternative scenarios of rainwater harvesting and composting toilet based technologies. In EEAST, building characteristics, occupancy, and precipitation are used to size the harvested rainwater and composting toilet systems. Then, life cycle costing and life cycle assessment methods are used to estimate cost, energy, and greenhouse gas (GHG) emission payback periods (PPs) for five alternative scenarios. The scenarios modeled include use of harvested rainwater for toilet flushing, for irrigation, or both; and use of composting toilets with or without harvested rainwater use for irrigation. A sample simulation using EEAST showed that for the office building modeled, the cost PPs were greater than energy PPs which in turn were greater than GHG emission PPs. This was primarily due to energy and emission intensive nature of the centralized water and wastewater infrastructure. The sample simulation also suggested that the composting toilets may have the best performance in all criteria. However, EEAST does not explicitly model solids management and as such may give composting toilets an unfair advantage compared to flush based toilets. EEAST results were found to be very sensitive to cost values used in the model. With the availability of EEAST, life cycle cost, energy, and GHG emissions can now be performed fairly easily by building designers and researchers. Future work is recommended to further improve EEAST and evaluate it for different types of buildings and climates so as to better understand when composting toilets and harvested rainwater systems outperform the BAU case in building design. Copyright © 2013 Elsevier Ltd. All rights reserved.

  2. Developing an automated water emitting-sensing system, based on integral tensiometers placed in homogenous environment.

    NASA Astrophysics Data System (ADS)

    Dabach, Sharon; Shani, Uri

    2010-05-01

    As the population grows, irrigated agriculture is using more water and fertilizers to supply the growing food demand. However, the uptake by various plants is only 30 to 50% of the water applied. The remaining water flows to surface water and groundwater and causes their contamination by fertilizers or other toxins such as herbicides or pesticides. To improve the water use efficiency of crops and decrease the drainage below the root zone, irrigation water should be applied according to the plant demand. The aim of this work is to develop an automated irrigation system based on real-time feedback from an inexpensive and reliable integrated sensing system. This system will supply water to plants according to their demand, without any user interference during the entire growth season. To achieve this goal a sensor (Geo-Tensiometer) was designed and tested. This sensor has better contact with the surrounding soil, is more reliable and much cheaper than the ceramic cup tensiometer. A lysimeter experiment was conducted to evaluate a subsurface drip irrigation regime based on the Geo-Tensiometer and compare it to a daily irrigation regime. All of the drippers were wrapped in Geo-textile. By integrating the Geo-Tensiometer within the Geo-textile which surrounds the drippers, we created a homogenous media in the entire lysimeter in which the reading of the matric potential takes place. This media, the properties of which are set and known to us, encourages root growth therein. Root density in this media is very high; therefore most of the plant water uptake is from this area. The irrigation system in treatment A irrigated when the matric potential reached a threshold which was set every morning automatically by the system. The daily treatment included a single irrigation each morning that was set to return 120% of the evapotranspiration of the previous day. All Geo-Tensiometers were connected to an automated washing system, that flushed air trapped in the Geo-Tensiometers. In treatment A, the system discharge changed according to the plant water demand. The discharge changes followed the water uptake changes during the day and during the entire growth period without any user interference. The integration of Geo-Tensiometer into the emitter system, together with the irrigation regime, maintained high and constant water content in the root zone in comparison to other irrigation methods, such as daily drip irrigation. Reading the matric potential in this media yielded better indication of water availability to the plants than sensors placed 3 cm from the emitters. In addition, the amount of water drainage below the root zone decreased significantly and therefore the threat of polluting groundwater. Furthermore, the automated flushing system eliminated the need for manual maintenance of the tensiometers creating a user friendly system.

  3. Influence of Household Water Filters on Bacteria Growth and Trace Metals in Tap Water of Doha, Qatar.

    PubMed

    Nriagu, Jerome; Xi, Chuanwu; Siddique, Azhar; Vincent, Annette; Shomar, Basem

    2018-05-29

    Deteriorating water quality from aging infrastructure, growing threat of pollution from industrialization and urbanization, and increasing awareness about waterborne diseases are among the factors driving the surge in worldwide use of point-of-entry (POE) and point-of-use (POU) filters. Any adverse influence of such consumer point-of-use systems on quality of water at the tap remains poorly understood, however. We determined the chemical and microbiological changes in municipal water from the point of entry into the household plumbing system until it leaves from the tap in houses equipped with filters. We show that POE/POU devices can induce significant deterioration of the quality of tap water by functioning as traps and reservoirs for sludge, scale, rust, algae or slime deposits which promote microbial growth and biofilm formation in the household water distribution system. With changes in water pressure and physical or chemical disturbance of the plumbing system, the microorganisms and contaminants may be flushed into the tap water. Such changes in quality of household water carry a potential health risk which calls for some introspection in widespread deployment of POE/POU filters in water distribution systems.

  4. Investigation of DMSD Trend in the ISS Water Processor Assembly

    NASA Technical Reports Server (NTRS)

    Carter, Layne; Bowman, Elizabeth; Wilson, Mark; Gentry, Greg; Rector, Tony

    2013-01-01

    The ISS Water Recovery System (WRS) is responsible for providing potable water to the crew, to the Oxygen Generation System (OGS) for oxygen production via electrolysis, to the Waste & Hygiene Compartment (WHC) for flush water, and for experiments on ISS. The WRS includes the Water Processor Assembly (WPA) and the Urine Processor Assembly (UPA). The WPA processes condensate from the cabin air and distillate produced by the UPA. In 2010, an increasing trend in the Total Organic Carbon (TOC) in the potable water was ultimately identified as dimethylsilanediol (DMSD). The increasing trend was ultimately reversed after replacing the WPA's two multifiltration beds. However, the reason for the TOC trend and the subsequent recovery was not understood. A subsequent trend occurred in 2012. This paper summarizes the current understanding of the fate of DMSD in the WPA, how the increasing TOC trend occurred, and the plan for modifying the WPA to prevent recurrence.

  5. Column study of Cr(VI) removal by cationic hydrogel for in-situ remediation of contaminated groundwater and soil

    NASA Astrophysics Data System (ADS)

    Tang, Samuel C. N.; Yin, Ke; Lo, Irene M. C.

    2011-07-01

    Column experiments were conducted for examining the effectiveness of the cationic hydrogel on Cr(VI) removal from groundwater and soil. For in-situ groundwater remediation, the effects of background anions, humic acid (HA) and pH were studied. Cr(VI) has a higher preference for being adsorbed onto the cationic hydrogel than sulphate, bicarbonate ions and HA. However, the adsorbed HA reduced the Cr(VI) removal capacity of the cationic hydrogel, especially after regeneration of the adsorbents, probably due to the blockage of adsorption sites. The Cr(VI) removal was slightly influenced by the groundwater pH that could be attributed to Cr(VI) speciation. The 6-cycle regeneration and reusability study shows that the effectiveness of the cationic hydrogel remained almost unchanged. On average, 93% of the adsorbed Cr(VI) was recovered in each cycle and concentrated Cr(VI) solution was obtained after regeneration. For in-situ soil remediation, the flushing water pH had an insignificant effect on the release of Cr(VI) from the soils. Multiple-pulse flushing increased the removal of Cr(VI) from the soils. In contrast, more flushing water and longer operation may be required to achieve the same removal level by continuous flushing.

  6. Hand-pumps as reservoirs for microbial contamination of well water

    PubMed Central

    Ferguson, Andrew S.; Mailloux, Brian J.; Ahmed, Kazi M.; van Geen, Alexander; McKay, Larry D.; Culligan, Patricia J.

    2018-01-01

    The retention and release of total coliforms and Escherichia coli was investigated in hand-pumps removed from tubewells tapping a faecally contaminated aquifer in Matlab, Bangladesh, and from a new hand-pump deliberately spiked with E. coli. All hand-pumps were connected to reservoirs of sterile water and flushed. Faecal coliforms were observed in the discharge from all three of the previously used hand-pumps, at concentrations comparable to levels measured in discharge when they were attached to the tubewells. During daily flushing of one of the previously used hand-pumps, the concentration of total coliforms in the discharge remained relatively constant (≈103 MPN/100 mL). Concentrations of E. coli in the pump discharge declined over time, but E. coli was still detectable up to 29 days after the start of flushing. In the deliberately spiked hand-pump, E. coli was observed in the discharge over 125 days (t50 = 8 days) and found to attach preferentially to elastomeric materials within the hand-pump. Attempts to disinfect both the village and new hand-pumps using shock chlorination were shown to be unsuccessful. These results demonstrate that hand-pumps can act as persistent reservoirs for microbial indicator bacteria. This could potentially influence drinking water quality and bias testing of water quality. PMID:22048430

  7. Efficacy of air/water syringe tip sterilization.

    PubMed

    Inger, M; Bennani, V; Farella, M; Bennani, F; Cannon, R D

    2014-03-01

    Dental procedures involve contact between instruments and the patient's tissues, blood or saliva. This study evaluated the efficacy of the standardized sterilization of non-disposable air/water syringe tips and corrosion and contaminant build-up in these tips. The bacterial contamination of single-use and multiple-use non-disposable air/water syringe tips after routine use and sterilization was compared to that of single-use disposable tips by microbial culturing on PCA and blood agar plates. The effect of flushing the syringe tips prior to sterilization was also measured. The amount of corrosion in single-use and multiple-use non-disposable syringes was measured by SEM and EDS analyses. Non-disposable syringe tips had significantly (p < 0.05) greater bacterial contamination than single-use disposable tips. There were no statistically different levels of contamination between flushed and non-flushed non-disposable syringes or between single-use and multiple-use non-disposable syringes. SEM and EDS analyses showed greater evidence of corrosion and contaminant build-up in multiple-use syringes compared to single-use non-disposable syringes. Sterilization of non-disposable air/water syringes is not completely effective and rinsing, or the number of uses, does not affect the effectiveness of sterilization. There may be a lower risk of cross-infection from the use of disposable air/water syringe tips, instead of non-disposable ones. © 2014 Australian Dental Association.

  8. System for slicing wafers

    NASA Technical Reports Server (NTRS)

    1982-01-01

    A newly patented process for slicing silicon wafers that has distinct advantages over methods now widely used is described. The primary advantage of the new system is that it allows the efficient slicing of a number of ingots simultaneously at high speed. The cutting action is performed mechanically, most often with diamond particles that are transported to the cutting zone by a fluid vehicle or have been made an integral part of the blade by plating or impregnation. The new system uses a multiple or ganged band saw, arranged and spaced so that each side, or length, segment of a blade element, or loop, provides a cutting function. Each blade is maintained precisely in position by guides as it enters and leaves each ingot. The cutting action is performed with a conventional abrasive slurry composed of diamond grit suspended in an oil- or water-based vehicle. The distribution system draws the slurry from the supply reservoir and pumps it to the injection tubes to supply it to each side of each ingot. A flush system is provided at the outer end of the work-station zone. In order to reduce potential damage, a pneumatically driven flushing fluid is provided.

  9. Evaluation of appropriate system for reclaimed wastewater reuse in each area of Tokyo using GIS-based water balance model.

    PubMed

    Aramaki, T; Sugimoto, R; Hanaki, K; Matsuo, T

    2001-01-01

    The appropriate type of reclaimed wastewater reuse system in each area of Tokyo was evaluated from the aspect of economic efficiency, using a GIS-based water balances model. The following four reclaimed wastewater reuse systems and conventional waterworks and sewerage system were evaluated; "Rain water storage and use system", "Onsite wastewater treatment and reuse system", "Sewage treatment and reuse at an intermediate point on the sewer pipe" and "Treated water supply system in sewage treatment plant". In the case that we install them to office and residential buildings, the supplied volume by reclaimed wastewater reuse systems is 693 thousands m3/d, this corresponds to 15% of total water demand in the area. Furthermore, the effects of the following scenarios brought about by technological innovation in water treatment were investigated; the case that flush water in toilet and wastewater from kitchen are also available as source in a "onsite wastewater treatment and reuse system" and the case that reclaimed water is used for laundering in residential buildings. When reclaimed water is used for laundering in residential buildings, the supplied volume by these systems increases to 814 thousand m3/d in the case that these systems are installed to office and residential buildings.

  10. High voltage solar cell power generating system

    NASA Technical Reports Server (NTRS)

    Levy, E., Jr.; Opjorden, R. W.; Hoffman, A. C.

    1974-01-01

    A laboratory solar power system regulated by on-panel switches has been delivered for operating high power (3 kW), high voltage (15,000 volt) loads (communication tubes, ion thrusters). The modular system consists of 26 solar arrays, each with an integral light source and cooling system. A typical array contains 2,560 series-connected cells. Each light source consists of twenty 500-watt tungsten iodide lamps providing plus or minus 5 percent uniformity at one solar constant. An array temperature of less than 40 C is achieved using an infrared filter, a water-cooled plate, a vacuum hold-down system, and air flushing.

  11. Factors controlling the configuration of the fresh-saline water interface in the Dead Sea coastal aquifers: Synthesis of TDEM surveys and numerical groundwater modeling

    USGS Publications Warehouse

    Yechieli, Y.; Kafri, U.; Goldman, M.; Voss, C.I.

    2001-01-01

    TDEM (time domain electromagnetic) traverses in the Dead Sea (DS) coastal aquifer help to delineate the configuration of the interrelated fresh-water and brine bodies and the interface in between. A good linear correlation exists between the logarithm of TDEM resistivity and the chloride concentration of groundwater, mostly in the higher salinity range, close to that of the DS brine. In this range, salinity is the most important factor controlling resistivity. The configuration of the fresh-saline water interface is dictated by the hydraulic gradient, which is controlled by a number of hydrological factors. Three types of irregularities in the configuration of fresh-water and saline-water bodies were observed in the study area: 1. Fresh-water aquifers underlying more saline ones ("Reversal") in a multi-aquifer system. 2. "Reversal" and irregular residual saline-water bodies related to historical, frequently fluctuating DS base level and respective interfaces, which have not undergone complete flushing. A rough estimate of flushing rates may be obtained based on knowledge of the above fluctuations. The occurrence of salt beds is also a factor affecting the interface configuration. 3. The interface steepens towards and adjacent to the DS Rift fault zone. Simulation analysis with a numerical, variable-density flow model, using the US Geological Survey's SUTRA code, indicates that interface steep- ening may result from a steep water-level gradient across the zone, possibly due to a low hydraulic conductivity in the immediate vicinity of the fault.

  12. Graywater Use by the Army -- Is It Time Yet?

    DTIC Science & Technology

    2011-05-11

    codes and regulations. Where chlorine rs used for disinfection , the non-potable water shall contain not more than 4 mg/L of chloramines or free...filtration • Often minimal treatment then underground irrigation system  Many commercial package plants ► Filtered, disinfected product – fairly... Disinfection  Identification (labeling and dying)  Distribution  Permit to construct BUILDING STRONG® Other Concerns  Fixture flushing  Cooling

  13. Modelling the impact of wind stress and river discharge on Danshuei River plume

    USGS Publications Warehouse

    Liu, W.-C.; Chen, W.-B.; Cheng, R.T.; Hsu, M.-H.

    2008-01-01

    A three-dimensional, time-dependent, baroclinic, hydrodynamic and salinity model, UnTRIM, was performed and applied to the Danshuei River estuarine system and adjacent coastal sea in northern Taiwan. The model forcing functions consist of tidal elevations along the open boundaries and freshwater inflows from the main stream and major tributaries in the Danshuei River estuarine system. The bottom friction coefficient was adjusted to achieve model calibration and verification in model simulations of barotropic and baroclinic flows. The turbulent diffusivities were ascertained through comparison of simulated salinity time series with observations. The model simulation results are in qualitative agreement with the available field data. The validated model was then used to investigate the influence of wind stress and freshwater discharge on Dasnhuei River plume. As the absence of wind stress, the anticyclonic circulation is prevailed along the north to west coast. The model results reveal when winds are downwelling-favorable, the surface low-salinity waters are flushed out and move to southwest coast. Conversely, large amounts of low-salinity water flushed out the Danshuei River mouth during upwelling-favorable winds, as the buoyancy-driven circulation is reversed. Wind stress and freshwater discharge are shown to control the plume structure. ?? 2007 Elsevier Inc. All rights reserved.

  14. Ecosystem impacts of Alpine water intakes for hydropower: the challenge of sediment management

    NASA Astrophysics Data System (ADS)

    Gabbud, Chrystelle; Lane, Stuart

    2016-04-01

    Natural Alpine flow regimes are strongly modified by anthropogenic activities, notably water abstraction or impoundment for hydroelectric power production, which impacts upon both river discharge and sediment transfer systems, and in turn upon flora and fauna downstream. These kinds of impacts are well studied where rivers are regulated by dams, with sediment retained in the associated reservoirs although occasional flushing may be required (a frequency typically of many years). Such impacts may be managed by environmental flows or e-flows, whose restoration value has been shown in a number of research publications. However, there has been less attention in relation to the e-flows needed at water intakes which in Alpine environments may be associated with serious sediment-related problems. Water intakes have a very smaller sediment storage capacity than dams and thus may need to be flushed of accumulated sediment more regularly. In an Alpine setting, because rates of erosion are naturally higher, sediment is flushed in 'purges' with a frequency that may even be sub-daily at certain times of the year. Purges feed the river with solid material, but as the means of transporting it, the water, is being abstracted, sediment transport capacity is reduced. In theory, this does not eliminate sediment connectivity, but rather reduces it: the sediment is still delivered, but it can only be transported for a reduced duration; and the results may be profound hydrogeomorphic and ecosystem impacts, including downstream aggradation. In this study, we present results from a combined study of fluvial geomorphology, hydrology and ecosystem impacts of flow abstraction at water intakes. Using hydrodynamic modelling, we show that because the duration of remobilisation of purges and the peak discharge are much shorter than under natural flows, this causes the formation of a zone of sediment aggradation that moves progressively downstream as a sediment wave, leading to sedimentation rates that are greater than the speed with which the ecosystem can adjust to them. The results is a clear ecological productivity and diversity decline. However, we also show that it is very difficult to design e-flows that can counter this process, because whilst sediment transport is a threshold-dependent non-linear transport process, in these kinds of streams, sediment transport under natural flows is almost continual during the summer months. The sediment transport capacity of the system is reduced in almost direct proportion to the volume of water abstracted, such that e-flows cannot be redesigned to manage sediment without completely undermining hydroelectric power production. This, we argue that managing the sediment regime in this kind of system needs a very different approach.

  15. Contrasts in Flushing Patterns Among Solutes

    NASA Astrophysics Data System (ADS)

    Shanley, J. B.; Sebestyen, S. D.; Boyer, E. W.; Ross, D. S.

    2005-12-01

    High-frequency sampling since 1991 at the 41-ha forested W-9 catchment at Sleepers River, Vermont provides a wealth of data to evaluate catchment flushing responses. Snowmelt and rain-on-snow account for about half the annual flow at Sleepers River during a 6-week period in early spring. Summer and fall storms produce frequent high-flows of short duration. Flushing of weathering products (Ca, Mg, Na, K, SO4 ANC, Si) is generally supply-limited, and is masked by rapid dilution with meteoric and soil water during events. In contrast, flushing dominates the stream dynamics of atmospheric and pedogenic solutes (NO3, DOC, Hg), causing concentration increases with increasing flow. During snowmelt, NO3 peaks well before the peak in discharge, whereas DOC tracks discharge closely and peaks concurrently. These patterns suggest that NO3 is supply-limited and DOC is transport-limited; W-9 is not N saturated and the available NO3 supply is readily leached from the soil, whereas stream DOC progressively increases as rising water tables and expanding saturated areas connect with new source areas. In summer storms, DOC and NO3 both peak simultaneously with discharge. Unlike DOC, however, NO3 concentrations are attenuated with subsequent storms that follow within a few days, consistent with a depletion of the NO3 pool available for flushing as observed during snowmelt. Sleepers River contrasts with the Snake River in Colorado, where NO3 and DOC reverse roles; DOC peaks early in snowmelt and may be supply-limited due to the paucity of organic matter. An ample supply of NO3 is available due to N saturation and N fixation, but NO3 may be transport-limited due to primary N sources in talus deposits far from the stream. Hg is an atmospheric solute that accumulates in soils because of its affinity for organic matter, and is flushed by high flows, mostly in association with suspended sediment. The concept of flushing provides a useful context for understanding the variable responses of solutes to the expansion of catchment saturation during high flow events.

  16. Removal of low-molecular weight DBPs and inorganic ions for characterization of high-molecular weight DBPs in drinking water.

    PubMed

    Zhang, Xiangru; Minear, Roger A

    2006-03-01

    High-molecular weight (MW) halogenated disinfection byproducts (DBPs) may cause adverse health effects. In this work several issues related to the better separation and characterization of the high MW halogenated DBPs (MW>500Da) were studied. Ultra-filtration (UF) coupled with a nominal 500-Da membrane was employed to flush out low MW DBPs and inorganic ions. Two procedures, intermittent UF and continuous UF, were used and compared. The results demonstrate that haloacetic acids, chloride and sodium ions could be effectively flushed out, and most of phosphate ions could be flushed out for a given dilution number or sufficient Milli-Q water. The size exclusion chromatograms indicate that haloacetic acids and trihalomethanes were not bound to Suwannee River fulvic acid (SRFA); 2,4,6-trichlorophenol might form some binding with SRFA, but it appeared to be very weak and readily broken up when passing along the size exclusion column. The octanol-water partition coefficients of low MW DBPs and the properties of humic substances seem to play key roles in determining the formation of possible bindings between low MW DBPs and humic substances.

  17. Re-engineering the urban drainage system for resource recovery and protection of drinking water supplies.

    PubMed

    Gumbo, B

    2000-01-01

    The Harare metropolis in Zimbabwe, extending upstream from Manyame Dam in the Upper Manyame River Basin, consists of the City of Harare and its satellite towns: Chitungwiza, Norton, Epworth and Ruwa. The existing urban drainage system is typically a single-use-mixing system: water is used and discharged to "waste", excreta are flushed to sewers and eventually, after "treatment", the effluent is discharged to a drinking water supply source. Polluted urban storm water is evacuated as fast as possible. This system not only ignores the substantial value in "waste" materials, but it also exports problems to downstream communities and to vulnerable fresh-water sources. The question is how can the harare metropolis urban drainage system, which is complex and has evolved over time, be rearranged to achieve sustainability (i.e. water conservation, pollution prevention at source, protection of the vulnerable drinking water sources and recovery of valuable materials)? This paper reviews current concepts regarding the future development of the urban drainage system in line with the new vision of "Sustainable Cities of the Future". The Harare Metropolis in Zimbabwe is taken as a case, and philosophical options for re-engineering the drainage system are discussed.

  18. Inhibition of soluble epoxide hydrolase limits niacin-induced vasodilation in mice

    PubMed Central

    Inceoglu, A. B.; Clifton, H.L.; Yang, J.; Hegedus, C.; Hammock, B. D.; Schaefer, S.

    2012-01-01

    Background The use of niacin in the treatment of dyslipidemias is limited by the common side effect of cutaneous vasodilation, commonly termed flushing. Flushing is thought to be due to release of the vasodilatory prostanoids PGD2 and PGE2 from arachidonic acid metabolism through the cyclooxygenase (COX) pathway. Arachidonic acid is also metabolized by the cytochrome P450 system which is regulated, in part, by the enzyme soluble epoxide hydrolase (sEH). Methods: These experiments used an established murine model in which ear tissue perfusion was measured by laser Doppler to test the hypothesis that inhibition of sEH would limit niacin-induced flushing. Results: Niacin-induced flushing was reduced from 506 ± 126 to 213 ± 39 % in sEH knockout animals. Pharmacologic treatment with 3 structurally distinct sEH inhibitors similarly reduced flushing in a dose dependent manner, with maximal reduction to 143±15% of baseline flow using a concentration of 1 mg/kg TPAU (1-trifluoromethoxyphenyl-3-(1-acetylpiperidin-4-yl) urea). Systemically administered PGD2 caused ear vasodilation which was not changed by either pharmacologic sEH inhibition or by sEH gene deletion. Conclusions: Inhibition of sEH markedly reduces niacin-induced flushing in this model without an apparent effect on the response to PGD2. sEH inhibition may be a new therapeutic approach to limit flushing in humans. PMID:22526297

  19. 46 CFR 194.15-11 - Flushing systems.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Flushing systems. 194.15-11 Section 194.15-11 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OCEANOGRAPHIC RESEARCH VESSELS HANDLING, USE, AND CONTROL OF EXPLOSIVES AND OTHER HAZARDOUS MATERIALS Chemistry Laboratory and Scientific Laboratory...

  20. 46 CFR 194.15-11 - Flushing systems.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 7 2013-10-01 2013-10-01 false Flushing systems. 194.15-11 Section 194.15-11 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OCEANOGRAPHIC RESEARCH VESSELS HANDLING, USE, AND CONTROL OF EXPLOSIVES AND OTHER HAZARDOUS MATERIALS Chemistry Laboratory and Scientific Laboratory...

  1. Intermittent operation of ultra-low pressure ultrafiltration for decentralized drinking water treatment.

    PubMed

    Peter-Varbanets, Maryna; Gujer, Willi; Pronk, Wouter

    2012-06-15

    River water was treated by ultrafiltration at a relatively low transmembrane pressure (40 mbar). As observed before, flux stabilization occurred after several days of operation although no back-flushing or cross flow was applied. Interruptions in flux were applied by temporary offset of the transmembrane pressure. After restoration of the transmembrane pressure, the initial flux was higher than the stable flux level, and the flux recovery depended on the standstill time. Furthermore, if a short cross flow was applied after standstill, the flux was restored to an even higher level. In all cases, the flux decreased again during operation to reach finally the same stable level as before standstill. In order to evaluate the influence of intermittent operation as practiced for water treatment on a household level, daily interruptions of flux were applied. An optimum of total daily water production rate was obtained at 21 h of operation and 3 h of standstill per day. A model was developed which can describe the impact of intermittent operation on the flux depending on the duration of the standstill and operating periods. This enables the prediction of production capacity of the system operated intermittently. The flux increase during standstill could be explained by a relaxation and expansion of the biofouling layer, while the higher flux after forward-flushing was caused by this layer being partially sloughed off. Household water treatment with the process presented here will generally be operated on a discontinuous basis. The results show that such operation schemes do not compromise the permeability of the system, but actually lead to higher fluxes after standstill. Copyright © 2012 Elsevier Ltd. All rights reserved.

  2. 40 CFR 141.807 - Recordkeeping requirements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Section 141.807 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS Aircraft Drinking Water Rule § 141.807 Recordkeeping... carrier must keep records of any disinfection and flushing for at least 5 years and must include the...

  3. 40 CFR 141.807 - Recordkeeping requirements.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Section 141.807 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS Aircraft Drinking Water Rule § 141.807 Recordkeeping... carrier must keep records of any disinfection and flushing for at least 5 years and must include the...

  4. 40 CFR 141.807 - Recordkeeping requirements.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Section 141.807 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS Aircraft Drinking Water Rule § 141.807 Recordkeeping... carrier must keep records of any disinfection and flushing for at least 5 years and must include the...

  5. 40 CFR 141.807 - Recordkeeping requirements.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Section 141.807 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS Aircraft Drinking Water Rule § 141.807 Recordkeeping... carrier must keep records of any disinfection and flushing for at least 5 years and must include the...

  6. 40 CFR 141.807 - Recordkeeping requirements.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Section 141.807 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS Aircraft Drinking Water Rule § 141.807 Recordkeeping... carrier must keep records of any disinfection and flushing for at least 5 years and must include the...

  7. Test rig and particulate deposit and cleaning evaluation processes using the same

    DOEpatents

    Schroder, Mark Stewart; Woodmansee, Donald Ernest; Beadie, Douglas Frank

    2002-01-01

    A rig and test program for determining the amount, if any, of contamination that will collect in the passages of a fluid flow system, such as a power plant fluid delivery system to equipment assemblies or sub-assemblies, and for establishing methods and processes for removing contamination therefrom. In the presently proposed embodiment, the rig and test programs are adapted in particular to utilize a high-pressure, high-volume water flush to remove contamination from substantially the entire fluid delivery system, both the quantity of contamination and as disposed or deposited within the system.

  8. Water recycling at the Millennium Dome.

    PubMed

    Hills, S; Smith, A; Hardy, P; Birks, R

    2001-01-01

    Thames Water is working with the New Millennium Experience Company to provide a water recycling system for the Millennium Dome which will supply 500 m3/d of reclaimed water for WC and urinal flushing. The system will treat water from three sources: rainwater--from the Dome roof greywater--from handbasins in the toilet blocks groundwater--from beneath the Dome site The treatment technologies will range from "natural" reedbeds for the rainwater, to more sophisticated options, including biological aerated filters and membranes for the greywater and groundwater. Pilot scale trials were used to design the optimum configuration. In addition to the recycling system, water efficient devices will be installed in three of the core toilet blocks as part of a programme of research into the effectiveness of conservation measures. Data on water usage and customer behaviour will be collected via a comprehensive metering system. Information from the Dome project on the economics and efficiency of on-site recycling at large scale and data on water efficient devices, customer perception and behaviour will be of great value to the water industry. For Thames Water, the project provides vital input to the development of future water resource strategies.

  9. NHEXAS PHASE I MARYLAND STUDY--PESTICIDES IN WATER ANALYTICAL RESULTS

    EPA Science Inventory

    The Pesticides in Water data set contains analytical results for measurements of up to 10 pesticides in 388 water samples over 80 households. One-liter samples of tap water were collected after a two-minute flush from the tap identified by the resident as that most commonly used...

  10. Direct and Indirect Effects of Animal Detritus on Growth, Survival, and Mass of Invasive Container Mosquito Aedes albopictus (Diptera: Culicidae)

    PubMed Central

    YEE, DONALD A.; KESAVARAJU, BANUGOPAN; JULIANO, STEVEN A.

    2007-01-01

    Compared with plant detritus, animal detritus yields higher growth rates, survival, adult mass, and population growth of container-dwelling mosquitoes. It is unclear whether the benefit from animal detritus to larvae results from greater microorganism growth, direct ingestion of animal detritus by larvae, or some other mechanism. We tested alternative mechanisms by which animal detritus may benefit the invasive container-dwelling mosquito Aedesalbopictus (Skuse) (Diptera: Culicidae). In the laboratory, larvae were reared under three conditions with access to 1) detritus, but where microorganisms in the water column were reduced through periodic flushing; 2) water column microorganisms, but larvae had no direct access to detritus; or 3) both water column microorganisms and detritus. Access treatments were conducted for three masses of animal detritus: 0.005, 0.010, and 0.020 g. Water column bacterial productivity (measured via incorporation of [3H]leucine) decreased significantly with flushing and with larval presence. Removing microorganisms through flushing significantly reduced mass of adult mosquitoes (both sexes), and it significantly prolonged developmental times of females compared with treatments where water column microorganisms or microorganisms and detritus were available. Survival to adulthood was greatest when larvae had access to both water column microorganisms and 0.020 g of detritus, but it declined when only water column microorganisms were available or when 0.005 g of detritus was used. These findings indicate both direct (as a food source) and indirect (assisting with decomposition of detritus) roles of microorganisms in producing the benefit of animal detritus to container mosquito larvae. PMID:17695011

  11. A spatially resolved model of seasonal variations in phytoplankton and clam ( Tapes philippinarum) biomass in Barbamarco Lagoon, Italy

    NASA Astrophysics Data System (ADS)

    Spillman, C. M.; Hamilton, D. P.; Hipsey, M. R.; Imberger, J.

    2008-08-01

    Barbamarco Lagoon (area = 7 km 2) is in the Po River Delta, adjoining the Northern Adriatic Sea, and supports a commercially valuable clam ( Tapes philippinarum) fishery. This study investigated interactions of the lagoon with adjacent coastal waters and inland riverine inputs by modelling both the lagoon and the Northern Adriatic Sea, using a coupled three-dimensional (3D) hydrodynamic-ecological model (ELCOM-CAEDYM) adapted to include the clam population. The clam model accounted for carbon (C), nitrogen (N) and phosphorus (P) biomass in the benthos through parameterisations for filtration, excretion, egestion, respiration, mortality, and harvesting. Multiple clam size classes were included in a new population dynamics sub-model. Output from the coupled model was validated against hydrodynamic and water quality data from intensive field sampling and routine monitoring. Time scales of tidal flushing, primary production and clam grazing were investigated with the model to demonstrate that food supply to clam populations is dominated by phytoplankton inputs from the Northern Adriatic Sea. Effects of clam cultivation on nutrient concentrations and phytoplankton biomass in Barbamarco Lagoon were primarily localised, with strong tidal flushing minimising impacts of clam filtration on lagoon-wide nutrient concentrations at current clam stocking levels. Clam populations were found to alter the cycling of nutrients in the system, causing the lagoon to become a net sink for particulate organic matter and to export dissolved organic matter to the adjacent sea via tidal flushing. Ecosystem health and sensitivity of nutrient cycles to clam cultivation are important considerations for the long term sustainable management and potential expansion of the fishery.

  12. Numerical simulation of surfactant-enhanced remediation using UTCHEM

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Freeze, G.A.; Fountain, J.C.; Pope, G.A.

    1995-12-31

    The UTCHEM multiphase compositional simulator was used to model the migration and surfactant-enhanced remediation of perchloroethylene (PCE) in a test cell at Canadian Forces Base Borden, Ontario. A line of five injection wells was installed on one side of the test cell and a line of five withdrawal wells was installed on the opposite side of the cell. The injection and withdrawal wells penetrated the entire depth of the sand aquifer. A total of 231 liters of PCE was injected into a shallow well in the center of the test cell. Prior to surfactant flushing, 47 liters of free-phase PCE,more » which flowed into the injection and withdrawal wells over a two week period, was removed using a small-diameter plastic tube and a peristaltic pump. One to two months of water flooding (pump-and-treat), using the injection-withdrawal well system, flushed an additional 12 liters of PCE. Following the water flooding, an aqueous surfactant solution of 1% nonyl phenol ethoxylate and 1% phosphate ester of the nonyl phenol ethoxylate was circulated through the test cell via the injection-withdrawal wells. Between November 11, 1990 and May 29, 1991, a total of 130,000 liters of surfactant solution were recirculated through the test cell, during which time 62 liters of PCE were recovered. This paper describes preliminary scoping simulations of the surfactant flushing process at the Borden test site to demonstrate the capability of UTCHEM to model surfactant-enhanced remediation of a non-aqueous-phase liquid (NAPL). A discussion of efforts to simulate PCE migration is also presented.« less

  13. [Recording of ventricular pressure by conventional catheter manometer systems. Efficiency of several combinations of conventional catheters, modern transducers and catheter-flush systems (author's transl)].

    PubMed

    Hellige, G

    1976-01-01

    The experimentally in vitro determined dynamic response characteristics of 38 catheter manometer systems were uniform in the worst case to 5 c.p.s. and optimally to 26 c.p.s. Accordingly, some systems are only satisfactory for ordinary pressure recording in cardiac rest, while better systems record dp/dt correct up to moderate inotropic stimulation of the heart. In the frequency range of uniform response (amplitude error less +/- 5%) the phase distortion is also negligible. In clinical application the investigator is often restricted to special type of cardiac catheter. In this case a low compliant transducer yields superior results. In all examined systems the combination with MSD 10 transducers is best, whereas the combination with P 23 Db transducers leads to minimal results. An inadequate system for recording ventricular pressure pulses leads in most cases to overestimations of dp/dtmax. The use of low frequency pass filters to attenuate higher frequency artefacts is, under clinical conditions, not suitable for extending the range of uniform frequency response. The dynamic response of 14 catheter manometer systems with two types of continuous self flush units was determined. The use of the P 37 flush unit in combination with small internal diameter catheters leads to serious error in ordinary pressure recording, due to amplitude distortion of the lower harmonics. The frequency response characteristics of the combination of an Intraflow flush system and MSD 10 transducer was similar to the non-flushing P 23 Db transducer feature.

  14. Analysis and Results from a Flush Airdata Sensing (FADS) System in Close Proximity to Firing Rocket Nozzles

    NASA Technical Reports Server (NTRS)

    Ali, Aliyah N.; Borrer, Jerry L.

    2013-01-01

    This presentation presents information regarding the nose-cap flush airdata sensing (FADS) system on Orion's Pad Abort 1 (PA-1) vehicle. The purpose of the nose-cap FADS system was to test whether or not useful data could be obtained from a FADS system if it was placed in close proximity to firing rockets nozzles like the attitude control motor (ACM) nozzles on the PA-1 launch abort system (LAS). The nose-cap FADS systems use pressure measurements from a series of pressure ports which are arranged in a cruciform pattern and flush with the surface of the vehicle to estimate values of angle of attack, angle of side-slip, Mach number, impact pressure and free-stream static pressure.

  15. Water System Architectures for Moon and Mars Bases

    NASA Technical Reports Server (NTRS)

    Jones, Harry W.; Hodgson, Edward W.; Kliss, Mark H.

    2015-01-01

    Water systems for human bases on the moon and Mars will recycle multiple sources of wastewater. Systems for both the moon and Mars will also store water to support and backup the recycling system. Most water system requirements, such as number of crew, quantity and quality of water supply, presence of gravity, and surface mission duration of 6 or 18 months, will be similar for the moon and Mars. If the water system fails, a crew on the moon can quickly receive spare parts and supplies or return to Earth, but a crew on Mars cannot. A recycling system on the moon can have a reasonable reliability goal, such as only one unrecoverable failure every five years, if there is enough stored water to allow time for attempted repairs and for the crew to return if repair fails. The water system that has been developed and successfully operated on the International Space Station (ISS) could be used on a moon base. To achieve the same high level of crew safety on Mars without an escape option, either the recycling system must have much higher reliability or enough water must be stored to allow the crew to survive the full duration of the Mars surface mission. A three loop water system architecture that separately recycles condensate, wash water, and urine and flush can improve reliability and reduce cost for a Mars base.

  16. Combination of Heat Shock and Enhanced Thermal Regime to Control the Growth of a Persistent Legionella pneumophila Strain

    PubMed Central

    Bédard, Emilie; Boppe, Inès; Kouamé, Serge; Martin, Philippe; Pinsonneault, Linda; Valiquette, Louis; Racine, Jules; Prévost, Michèle

    2016-01-01

    Following nosocomial cases of Legionella pneumophila, the investigation of a hot water system revealed that 81.5% of sampled taps were positive for L. pneumophila, despite the presence of protective levels of copper in the water. A significant reduction of L. pneumophila counts was observed by culture after heat shock disinfection. The following corrective measures were implemented to control L. pneumophila: increasing the hot water temperature (55 to 60 °C), flushing taps weekly with hot water, removing excess lengths of piping and maintaining a water temperature of 55 °C throughout the system. A gradual reduction in L. pneumophila counts was observed using the culture method and qPCR in the 18 months after implementation of the corrective measures. However, low level contamination was retained in areas with hydraulic deficiencies, highlighting the importance of maintaining a good thermal regime at all points within the system to control the population of L. pneumophila. PMID:27092528

  17. Simulating Streamflow and Dissolved Organic Matter Export from small Forested Watersheds

    NASA Astrophysics Data System (ADS)

    Xu, N.; Wilson, H.; Saiers, J. E.

    2010-12-01

    Coupling the rainfall-runoff process and solute transport in catchment models is important for understanding the dynamics of water-quality-relevant constituents in a watershed. To simulate the hydrologic and biogeochemical processes in a parametrically parsimonious way remains challenging. The purpose of this study is to quantify the export of water and dissolved organic matter (DOM) from a forested catchment by developing and testing a coupled model for rainfall-runoff and soil-water flushing of DOM. Natural DOM plays an important role in terrestrial and aquatic systems by affecting nutrient cycling, contaminant mobility and toxicity, and drinking water quality. Stream-water discharge and DOM concentrations were measured in a first-order stream in Harvard Forest, Massachusetts. These measurements show that stream water DOM concentrations are greatest during hydrologic events induced by rainfall or snowmelt and decline to low, steady levels during periods of baseflow. Comparison of the stream-discharge data to calculations of a simple rainfall-runoff model reveals a hysteretic relationship between stream-flow rates and the storage of water within the catchment. A modified version of the rainfall-runoff model that accounts for hysteresis in the storage-discharge relationship in a parametrically simple way is capable of describing much, but not all, of the variation in the time-series data on stream discharge. Our ongoing research is aimed at linking the new rainfall-runoff formulation with coupled equations that predict soil-flushing and stream-water concentrations of DOM as functions of the temporal change in catchment water storage. This model will provide a predictive tool for examining how changes in climatic variables would affect the runoff generation and DOM fluxes from terrestrial landscape.

  18. The development of a novel approach for assessment of the first flush in urban stormwater discharges.

    PubMed

    Bach, P M; McCarthy, D T; Deletic, A

    2010-01-01

    The management of stormwater pollution has placed particular emphasis on the first flush phenomenon. However, definition and current methods of analyses of the phenomena contain serious limitations, the most important being their inability to capture a possible impact of the event size (total event volume) on the first flush. This paper presents the development of a novel approach in defining and assessing the first flush that should overcome these problems. The phenomenon is present in a catchment if the decrease in pollution concentration with the absolute cumulative volume of runoff from the catchment is statistically significant. Using data from seven diverse catchments around Melbourne, Australia, changes in pollutant concentrations for Total Suspended Solids (TSS) and Total Nitrogen (TN) were calculated over the absolute cumulative runoff and aggregated from a collection of different storm events. Due to the discrete nature of the water quality data, each concentration was calculated as a flow-weighted average at 2 mm runoff volume increments. The aggregated concentrations recorded in each increment (termed as a 'slice' of runoff) were statistically compared to each other across the absolute cumulative runoff volume. A first flush is then defined as the volume at which concentrations reach the 'background concentration' (i.e. the statistically significant minimum). Initial results clearly highlight first flush and background concentrations in all but one catchment supporting the validity of this new approach. Future work will need to address factors, which will help assess the first flush's magnitude and volume. Sensitivity testing and correlation with catchment characteristics should also be undertaken.

  19. Benthic Flux Sampling Device. Operations, Methods, and Procedures

    DTIC Science & Technology

    1993-02-01

    nitric acid (HNO3) overnight, then rinse with D.I. water. When in doubt, consult with the chemist for proper cleaning protocols. CHARGE BATTERIES...sis being performed. The system will be flushed with methanol to remove organic com- pounds and with nitric acid to remove metals. The nitric acid ... acid -washed, 500-me Teflon (TFE) sampling bottles aboard the BFSD. After each deployment, blank ferrules are fitted in place of the sampling lines and

  20. Hair tonic poisoning

    MedlinePlus

    ... health care provider tells you to. If the chemical is on the skin or in the eyes, flush with lots of water for at least 15 minutes. If the person swallowed the hair tonic, give them water or milk right away, ...

  1. Hair bleach poisoning

    MedlinePlus

    ... health care provider tells you to. If the chemical is on the skin or in the eyes, flush with lots of water for at least 15 minutes. If the person swallowed the hair bleach, give them water or milk right away, ...

  2. Do piped water and flush toilets prevent child diarrhea in rural Philippines?

    PubMed

    Capuno, Joseph J; Tan, Carlos Antonio R; Fabella, Vigile Marie

    2015-03-01

    Similar to other developing countries, diarrhea in the Philippines continues to be among the top causes of child mortality and morbidity. In pursuit of its Millennium Development Goals, the Philippine government commits to reduce child deaths and provide water and sanitation services to more rural households by 2015. Applying propensity score matching on the 1993, 1998, 2003, and 2008 rounds of the National Demographic and Health Survey to estimate the average treatment effect on the treated, it is found that the incidence of diarrhea among under-5 children is lower by as much as 4.5% in households with access to piped water and 10% in those with their own flush toilets, relative to comparable households. These findings underscore the need to ensure the quality of drinking water from the pipe or from other improved sources at the point of use, and the provision of improved and own sanitation facilities. © 2011 APJPH.

  3. Impact of backwashing procedures on deep bed filtration productivity in drinking water treatment.

    PubMed

    Slavik, Irene; Jehmlich, Alexander; Uhl, Wolfgang

    2013-10-15

    Backwash procedures for deep bed filters were evaluated and compared by means of a new integrated approach based on productivity. For this, different backwash procedures were experimentally evaluated by using a pilot plant for direct filtration. A standard backwash mode as applied in practice served as a reference and effluent turbidity was used as the criterion for filter run termination. The backwash water volumes needed, duration of the filter-to-waste period, time out of operation, total volume discharged and filter run-time were determined and used to calculate average filtration velocity and average productivity. Results for filter run-times, filter backwash volumes, and filter-to-waste volumes showed considerable differences between the backwash procedures. Thus, backwash procedures with additional clear flushing phases were characterised by an increased need for backwash water. However, this additional water consumption could not be compensated by savings during filter ripening. Compared to the reference backwash procedure, filter run-times were longer for both single-media and dual-media filters when air scour and air/water flush were optimised with respect to flow rates and the proportion of air and water. This means that drinking water production time is longer and less water is needed for filter bed cleaning. Also, backwashing with additional clear flushing phases resulted in longer filter run-times before turbidity breakthrough. However, regarding the productivity of the filtration process, it was shown that it was almost the same for all of the backwash procedures investigated in this study. Due to this unexpected finding, the relationships between filter bed cleaning, filter ripening and filtration performance were considered and important conclusions and new approaches for process optimisation and resource savings were derived. Copyright © 2013 Elsevier Ltd. All rights reserved.

  4. Flushing Disorders Associated with Gastrointestinal Symptoms: Part 1, Neuroendocrine Tumors, Mast Cell Disorders and Hyperbasophila.

    PubMed

    Rastogi, Vaibhav; Singh, Devina; Mazza, Joseph J; Yang, Dennis; Parajuli, Dipendra; Yale, Steven H

    2018-04-12

    Flushing is the subjective sensation of warmth accompanied by visible cutaneous erythema occurring throughout the body with a predilection for the face, neck, pinnae, and upper trunk where the skin is thinnest and cutaneous vessels are superficially located and in greatest numbers. Flushing can be present in either a wet or dry form depending upon whether neural-mediated mechanisms are involved. Activation of the sympathetic nervous system results in wet flushing, accompanied by diaphoresis, due to concomitant stimulation of eccrine sweat glands. Wet flushing is caused by certain medications, panic disorder and paroxysmal extreme pain disorder (PEPD). Vasodilator mediated flushing due to the formation and release of a variety of biogenic amines, neuropeptides and phospholipid mediators such as histamine, serotonin and prostaglandins respectively, typically presents as dry flushing where sweating is characteristically absent. Flushing occurring with neuroendocrine tumors accompanied by gastrointestinal symptoms is generally of the dry flushing variant, which may be an important clinical clue to the differential diagnosis. A number of primary diseases of the gastrointestinal tract cause flushing, and conversely extra-intestinal conditions are associated with flushing and gastrointestinal symptoms. Gastrointestinal findings vary and include one or more of the following non-specific symptoms such as abdominal pain, nausea, vomiting, diarrhea or constipation. The purpose of this review is to provide a focused comprehensive discussion on the presentation, pathophysiology, diagnostic evaluation and management of those diseases that arise from the gastrointestinal tract or other site that may cause gastrointestinal symptoms secondarily accompanied by flushing. The paper is divided into two parts given the scope of conditions that cause flushing and affect the gastrointestinal tract. Part 1 covered is neuroendocrine tumors, (carcinoid, pheochromocytomas, vasoactive intestinal polypeptide, medullary carcinoma of the thyroid) polyneuropathy, organomegaly, endocrinopathy, monoclonal protein, skin changes (POEMS), and conditions involving mast cells and basophils. Part 2 covered is dumping syndrome, mesenteric traction syndrome, rosacea, hyperthyroidism and thyroid storm, anaphylaxis, panic disorders, paroxysmal extreme pain disorder, and food, alcohol and medications. © 2018 Marshfield Clinic.

  5. Mass Transfer from Entrapped DNAPL Sources Undergoing Remediation: Characterization Methods and Prediction Tools

    DTIC Science & Technology

    2006-08-31

    volumetric depletion efficiency ( VDE ) considers how much DNAPL is depleted from the system, relative to the total volume of solution flushed through the...aqueous phase contaminant. VDE is important to consider, as conditions that result in the fastest mass transfer, highest enhancement, or best MTE, may...volumes of flushing fluid, maximizing DNAPL depletion while minimizing flushing volume requirements may be desirable from a remediation standpoint. VDE

  6. 33 CFR 401.30 - Ballast water and trim.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... flushing is defined as the addition of mid-ocean water to ballast water tanks: The mixing of the flushwater..., such that the resultant residual water remaining in the tank has as high salinity as possible, and is at least 30 parts per thousand (ppt). The vessel shall take on as much mid-ocean water into each tank...

  7. 33 CFR 401.30 - Ballast water and trim.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... flushing is defined as the addition of mid-ocean water to ballast water tanks: The mixing of the flushwater..., such that the resultant residual water remaining in the tank has as high salinity as possible, and is at least 30 parts per thousand (ppt). The vessel shall take on as much mid-ocean water into each tank...

  8. Army Water Reuse Policy - A Decision Document

    DTIC Science & Technology

    2010-06-01

    Marsh enhancement Streamflow augmentation Fisheries Nonpotable urban uses Fire protection Air conditioning Toilet flushing Water features US Army Corps...policy Use of IPR from suppliers or to practice on Army facilities Impact of privatization US Army Corps of Engineers® Engineer Research and...Development Center Definitions Graywater = Greywater = Gray Water = Grey Water Blackwater Toilet , Kitchen Wastewater Reclaimed Water Wastewater Treated

  9. NHEXAS PHASE I MARYLAND STUDY--METALS IN WATER ANALYTICAL RESULTS

    EPA Science Inventory

    The Metals in Water data set contains analytical results for measurements of up to 11 metals in 400 water samples over 80 households. One-liter samples of tap water were collected after a two minute flush from the tap identified by the resident as that most commonly used for dri...

  10. High voltage solar cell power generating system for regulated solar array development

    NASA Technical Reports Server (NTRS)

    Levy, E., Jr.; Hoffman, A. C.

    1973-01-01

    A laboratory solar power system regulated by on-panel switches has been delivered for operating high power (3 kw), high voltage (15,000 volt) loads (communication tubes, ion thrusters). The modular system consists of 26 solar arrays, each with an integral light source and cooling system. A typical array contains 2560 series-connected cells. Each light source consists of twenty 500 watt tungsten iodide lamps providing plus or minus 5 per cent uniformity at one solar constant. An array temperature of less than 40 C is achieved using an infrared filter, a water cooled plate, a vacuum hold-down system, and air flushing.

  11. Nutrient and other environmental controls of harmful cyanobacterial blooms along the freshwater-marine continuum.

    PubMed

    Paerl, Hans

    2008-01-01

    Nutrient and hydrologic conditions strongly influence harmful planktonic and benthic cyanobacterial bloom (CHAB) dynamics in aquatic ecosystems ranging from streams and lakes to coastal ecosystems. Urbanization, agricultural and industrial development have led to increased nitrogen (N) and phosphorus (P) discharge, which affect CHAB potentials of receiving waters. The amounts, proportions and chemical composition of N and P sources can influence the composition, magnitude and duration of blooms. This, in turn, has ramifications for food web dynamics (toxic or inedible CHABs), nutrient and oxygen cycling and nutrient budgets. Some CHABs are capable of N2 fixation, a process that can influence N availability and budgets. Certain invasive N2 fixing taxa (e.g., Cylindrospermopsis, Lyngbya) also effectively compete for fixed N during spring, N-enriched runoff periods, while they use N2 fixation to supplant their N needs during N-deplete summer months. Control of these taxa is strongly dependent on P supply. However, additional factors, such as molar N:P supply ratios, organic matter availability, light attenuation, freshwater discharge, flushing rates (residence time) and water column stability play interactive roles in determining CHAB composition (i.e. N2 fixing vs. non-N2 fixing taxa) and biomass. Bloom potentials of nutrient-impacted waters are sensitive to water residence (or flushing) time, temperatures (preference for > 15 degrees C), vertical mixing and turbidity. These physical forcing features can control absolute growth rates of bloom taxa. Human activities may affect "bottom up" physical-chemical modulators either directly, by controlling hydrologic, nutrient, sediment and toxic discharges, or indirectly, by influencing climate. Control and management of cyanobacterial and other phytoplankton blooms invariably includes nutrient input constraints, most often focused on N and/or P. While single nutrient input constraints may be effective in some water bodies, dual N and P input reductions are usually required for effective long-term control and management of blooms. In some systems where hydrologic manipulations (i.e., plentiful water supplies) are possible, reducing the water residence time by flushing and artificial mixing (along with nutrient input constraints) can be effective alternatives. Blooms that are not readily consumed and transferred up the food web will form a relatively large proportion of sedimented organic matter. This, in turn, will exacerbate sediment oxygen demand, and enhance the potential for oxygen depletion and release of nutrients back to the water column. This scenario is particularly problematic in long-residence time (i.e., months) systems, where blooms may exert a strong positive feedback on future events. Implications of these scenarios and the confounding issues of climatic (hydrologic) variability, including droughts, tropical storms, hurricanes and floods, will be discussed in the context of developing effective CHAB control strategies along the freshwater-marine continuum.

  12. Tidal-flow, circulation, and flushing characteristics of Kings Bay, Citrus County, Florida

    USGS Publications Warehouse

    Hammett, K.M.; Goodwin, C.R.; Sanders, G.L.

    1996-01-01

    Kings Bay is an estuary on the gulf coast of peninsular Florida with a surface area of less than one square mile. It is a unique estuarine system with no significant inflowing rivers or streams. As much as 99 percent of the freshwater entering the bay originates from multiple spring vents at the bottom of the estuary. The circulation and flushing characteristics of Kings Bay were evaluated by applying SIMSYS2D, a two-dimensional numerical model. Field data were used to calibrate and verify the model. Lagrangian particle simulations were used to determine the circulation characteristics for three hydrologic conditions: low inflow, typical inflow, and low inflow with reduced friction from aquatic vegetation. Spring discharge transported the particles from Kings Bay through Crystal River and out of the model domain. Tidal effects added an oscillatory component to the particle paths. The mean particle residence time was 59 hours for low inflow with reduced friction; therefore, particle residence time is affected more by spring discharge than by bottom friction. Circulation patterns were virtually identical for the three simulated hydroloigc conditions. Simulated particles introduced in the southern part of Kings Bay traveled along the eastern side of Buzzard Island before entering Crystal River and existing the model domain. The flushing characteristics of Kings Bay for the three hydrodynamic conditions were determined by simulating the injection of conservative dye constituents. The average concentration of dye initially injected in Kings Bay decreased asymptotically because of spring discharge, and the tide caused some oscillation in the average dye concentration. Ninety-five percent of the injected dye exited Kings Bay and Crystal River with 94 hours for low inflow, 71 hours for typical inflow, and 94 hours for low inflow with reduced bottom friction. Simulation results indicate that all of the open waters of Kings Bay are flushed by the spring discharge. Reduced bottom friction has little effect on flushing.

  13. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Maienschein, J.L.; Garcia, F.; Garza, R.G.

    Tritium-handling apparatus has been decontaminated as part of the shutdown of the LLNL Tritium Facility. Two stainless-steel gloveboxes that had been used to process lithium deuteride-tritide (LiDT) salt were decontaminated using the Portable Cleanup System so that they could be flushed with room air through the facility ventilation system. Further surface decontamination was performed by scrubbing the interior with paper towels and ethyl alcohol or Swish{trademark}. The surface contamination, as shown by swipe surveys, was reduced from 4{times}10{sup 4}--10{sup 6} disintegrations per minute (dpm)/cm{sup 2} to 2{times}10{sup 2}--4{times}10{sup 4} dpm/cm{sup 2}. Details on the decontamination operation are provided. A seriesmore » of metal (palladium and vanadium) hydride storage beds have been drained of tritium and flushed with deuterium in order to remove as much tritium as possible. The bed draining and flushing procedure is described, and a calculational method is presented which allows estimation of the tritium remaining in a bed after it has been drained and flushed. Data on specific bed draining and flushing are given.« less

  14. Environmental occurrence and shallow ground water detection of the antibiotic monensin from dairy farms

    USGS Publications Warehouse

    Watanabe, N.; Harter, T.H.; Bergamaschi, B.A.

    2008-01-01

    Pharmaceuticals used in animal feeding operations have been detected in various environmental settings. There is a growing concern about the impact on terrestrial and aquatic organisms and the development of antibiotic-resistant strains of microorganisms. Pharmaceutical use in milking cows is relatively limited compared with other livestock operations, except for the ionophore monensin, which is given to lactating cows as a feed. By weight, monensin can be the most significant antibiotic used in a dairy farm. This study investigates the potential of monensin to move from dairy operations into the surrounding ground water. Using two dairy farms in California as study sites, we twice collected samples along the environmental pathway-from flush lanes, lagoon waters, and shallow ground water beneath the dairies and beneath its associated manured fields. Monensin concentrations were determined using solid-phase extraction and liquid chromatography-tandem mass spectrometry with positive electrospray ionization. Monensin was detected in all of the flush lane and lagoon water samples. Theoretical maximum concentration estimated from the actual dosing rate and the theoretical excretion rate assuming no attenuation was one order of magnitude greater than observed concentrations, suggesting significant attenuation in the manure collection and storage system. Monensin was also detected, at levels ranging from 0.04 to 0.39 microg L(-1), in some of the ground water samples underneath the production area of the dairy but not from the adjacent manured fields. Concentrations in ground water immediately downgradient of the lagoons were one to two orders of magnitude lower than the concentrations detected in lagoons, suggesting attenuation in the subsurface. The data suggest the possibility of monensin transport into shallow (2-5 m) alluvial ground water from dairy management units, including manure storage lagoons and freestalls occupied by heifers, lactating cows, and dry cows.

  15. Flushing Out Solutions.

    ERIC Educational Resources Information Center

    Baz, Jose

    1997-01-01

    Discusses the use of pressure-assist technology to cut water usage volume in schools. It answers questions concerning whether to retrofit school washrooms with pressure-assisted technology and how much water would be conserved. Where to get more information on washrooms is provided. (GR)

  16. Membrane fouling and anti-fouling strategies using RO retentate from a municipal water recycling plant as the feed for osmotic power generation.

    PubMed

    Chen, Si Cong; Amy, Gary L; Chung, Tai-Shung

    2016-01-01

    RO retentate from a municipal water recycling plant is considered as a potential feed stream for osmotic power generation in this paper. The feasibility of using RO retentate from a municipal water recycling plant was examined from two aspects: (a) the membrane fouling propensity of RO retentate, and (b) the efficacy of anti-fouling strategies. The membranes used in this study were the inner selective thin film composite polyethersulfone (TFC/PES) hollow fiber membranes, which possessed a high water permeability and good mechanical strength. Scaling by phosphate salts was found to be one possible inorganic fouling on the innermost layer of the PES membrane, whereas silica fouling was observed to be the governing fouling on the outmost surface of the PES membrane. Two anti-fouling pretreatments, i.e., pH adjustment and anti-scalant pre-treatment for the feed stream, were studied and found to be straightforward and effective. Using RO retentate at pH 7.2 as the feed and 1 M NaCl as the draw solution, the average power density was 7.3 W/m(2) at 20 bar. The average power density increased to 12.6 W/m(2) by modifying RO retentate with an initial pH value of 5.5 using HCl and to 13.4 W/m(2) by adding 1.1 mM ethylenediaminetetraacetic acid (EDTA). Moreover, the flux recovery of the fouled membranes, without the indicated pretreatments, reached 84.9% using deionized (DI) water flushing and 95.0% using air bubbling under a high crossflow velocity of 23.3 cm/s (Re = 2497) for 30 min. After pretreatment by pH adjustment, the flux recovery increased to 94.6% by DI water flushing and 100.0% by air bubbling. After pretreatment by adding 1.1 mM EDTA into RO retentate, flux was almost fully restored by physical cleaning by DI water flushing and air bubbling. These results provide insight into developing an effective pretreatment by either pH adjustment or EDTA addition before PRO and physical cleaning methods by DI water flushing and air bubbling for membrane used in osmotic power generation. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. Incineration for resource recovery in a closed ecological life support system

    NASA Technical Reports Server (NTRS)

    Upadhye, R. S.; Wignarajah, K.; Wydeven, T.

    1993-01-01

    A functional schematic, including mass and energy balance, of a solid waste processing system for a controlled ecological life support system (CELSS) was developed using Aspen Plus, a commercial computer simulation program. The primary processor in this system is an incinerator for oxidizing organic wastes. The major products derived from the incinerator are carbon dioxide and water, which can be recycled to a crop growth chamber (CGC) for food production. The majority of soluble inorganics are extracted or leached from the inedible biomass before they reach the incinerator, so that they can be returned directly to the CGC and reused as nutrients. The heat derived from combustion of organic compounds in the incinerator was used for phase-change water purification. The waste streams treated by the incinerator system conceptualized in this work are inedible biomass from a CGC, human urine (including urinal flush water) and feces, humidity condensate, shower water, and trash. It is estimated that the theoretical minimum surface area required for the radiator to reject the unusable heat output from this system would be 0.72 sq m/person at 298 K.

  18. Incremental sanitation improvement strategy: comparison of options for Hanoi, Vietnam.

    PubMed

    Harada, H; Matsui, S; Dong, N T; Shimizu, Y; Fujii, S

    2010-01-01

    Urban sanitation issues should be tackled strategically, and may be addressed effectively when sewage development is pursued in conjunction with complementary sanitation measures. Five sanitation improvement scenarios employing sewage, night-soil collection-and-treatment (NSCT) system, and/or septic-tank improvement by annual dislodging were analyzed from the perspective of COD loads, total nitrogen loads, and cost under the conditions found in Hanoi, Vietnam. Compared to the development of sewage alone, the scenario of developing NSCT systems in a complementary manner with sewage development was estimated to be the most effective for a rapid decrease of both COD and total nitrogen loads. However, it may be difficult in some cases to replace ordinary water-flush toilet by the micro-flush toilet that are used in NSCT systems. In this case, the scenario employing septic-tank improvement in conjunction with sewage development may be effective for a rapid decrease of COD in locations where septic tanks are widely used under poor maintenance conditions and nitrogen pollution is not serious compared to COD. It was calculated that the two scenarios above would respectively require cost increases of 16 and 22% over the sewage development scenario.

  19. Effect of pronase as mucolytic agent on imaging quality of magnifying endoscopy.

    PubMed

    Kim, Gwang Ha; Cho, Yu Kyung; Cha, Jae Myung; Lee, Sun-Young; Chung, Il-Kwun

    2015-02-28

    To investigate the efficacy of premedication with pronase, a proteolytic enzyme, in improving image quality during magnifying endoscopy. The study was of a blinded, randomized, prospective design. Patients were assigned to groups administered oral premedication of either pronase and simethicone (Group A) or simethicone alone (Group B). First, the gastric mucosal visibility grade (1-4) was determined during conventional endoscopy, and then a magnifying endoscopic examination was conducted. The quality of images obtained by magnifying endoscopy at the stomach and the esophagus was scored from 1 to 3, with a lower score indicating better visibility. The endoscopist used water flushes as needed to obtain satisfactory magnifying endoscopic views. The main study outcomes were the visibility scores during magnifying endoscopy and the number of water flushes. A total of 144 patients were enrolled, and data from 143 patients (M:F=90:53, mean age 57.5 years) were analyzed. The visibility score was significantly higher in the stomach following premedication with pronase (73% with a score of 1 in Group A vs 49% in Group B, P<0.05), but there was no difference in the esophagus visibility scores (67% with a score of 1 in Group A vs 58% in Group B). Fewer water flushes [mean 0.7±0.9 times (range: 0-3 times) in Group A vs 1.9±1.5 times (range: 0-6 times) in Group B, P<0.05] in the pronase premedication group did not affect the endoscopic procedure times [mean 766 s (range: 647-866 s) for Group A vs 760 s (range: 678-854 s) for Group B, P=0.88]. The total gastric mucosal visibility score was also lower in Group A (4.9±1.5 vs 8.3±1.8 in Group B, P<0.01). The addition of pronase to simethicone premedication resulted in clearer images during magnifying endoscopy and reduced the need for water flushes.

  20. Effect of pronase as mucolytic agent on imaging quality of magnifying endoscopy

    PubMed Central

    Kim, Gwang Ha; Cho, Yu Kyung; Cha, Jae Myung; Lee, Sun-Young; Chung, Il-Kwun

    2015-01-01

    AIM: To investigate the efficacy of premedication with pronase, a proteolytic enzyme, in improving image quality during magnifying endoscopy. METHODS: The study was of a blinded, randomized, prospective design. Patients were assigned to groups administered oral premedication of either pronase and simethicone (Group A) or simethicone alone (Group B). First, the gastric mucosal visibility grade (1-4) was determined during conventional endoscopy, and then a magnifying endoscopic examination was conducted. The quality of images obtained by magnifying endoscopy at the stomach and the esophagus was scored from 1 to 3, with a lower score indicating better visibility. The endoscopist used water flushes as needed to obtain satisfactory magnifying endoscopic views. The main study outcomes were the visibility scores during magnifying endoscopy and the number of water flushes. RESULTS: A total of 144 patients were enrolled, and data from 143 patients (M:F = 90:53, mean age 57.5 years) were analyzed. The visibility score was significantly higher in the stomach following premedication with pronase (73% with a score of 1 in Group A vs 49% in Group B, P < 0.05), but there was no difference in the esophagus visibility scores (67% with a score of 1 in Group A vs 58% in Group B). Fewer water flushes [mean 0.7 ± 0.9 times (range: 0-3 times) in Group A vs 1.9 ± 1.5 times (range: 0-6 times) in Group B, P < 0.05] in the pronase premedication group did not affect the endoscopic procedure times [mean 766 s (range: 647-866 s) for Group A vs 760 s (range: 678-854 s) for Group B, P = 0.88]. The total gastric mucosal visibility score was also lower in Group A (4.9 ± 1.5 vs 8.3 ± 1.8 in Group B, P < 0.01). CONCLUSION: The addition of pronase to simethicone premedication resulted in clearer images during magnifying endoscopy and reduced the need for water flushes. PMID:25741158

  1. Potential of household environmental resources and practices in eliminating residual malaria transmission: a case study of Tanzania, Burundi, Malawi and Liberia.

    PubMed

    Semakula, Henry M; Song, Guobao; Zhang, Shushen; Achuu, Simon P

    2015-09-01

    The increasing protection gaps of insecticide-treated nets and indoor-residual spraying methods against malaria have led to an emergence of residual transmission in sub-Saharan Africa and thus, supplementary strategies to control mosquitoes are urgently required. To assess household environmental resources and practices that increase or reduce malaria risk among children under-five years of age in order to identify those aspects that can be adopted to control residual transmission. Household environmental resources, practices and malaria test results were extracted from Malaria Indicators Survey datasets for Tanzania, Burundi, Malawi and Liberia with 16,747 children from 11,469 households utilised in the analysis. Logistic regressions were performed to quantify the contribution of each factor to malaria occurrence. Cattle rearing reduced malaria risk between 26%-49% while rearing goats increased the risk between 26%-32%. All piped-water systems reduced malaria risk between 30%-87% (Tanzania), 48%-95% (Burundi), 67%-77% (Malawi) and 58%-73 (Liberia). Flush toilets reduced malaria risk between 47%-96%. Protected-wells increased malaria risk between 19%-44%. Interestingly, boreholes increased malaria risk between 19%-75%. Charcoal use reduced malaria risk between 11%-49%. Vector control options for tackling mosquitoes were revealed based on their risk levels. These included cattle rearing, installation of piped-water systems and flush toilets as well as use of smokeless fuels.

  2. Redefining the stormwater first flush phenomenon.

    PubMed

    Bach, Peter M; McCarthy, David T; Deletic, Ana

    2010-04-01

    The first flush in urban runoff has been an important, yet disputed phenomenon amongst many researchers. The vast differences in the evidence could be solely due to limitations of the first flush current definition and the approach used for its assessment. There is a need for revisiting the first flush theory in the light of its practical applications to urban drainage management practices. We propose that a catchment's first flush behaviour is to be quantified by the runoff volume required to reduce a catchment's stormwater pollutant concentrations to background levels. The proposed method for assessment of this runoff volume starts by finding the average catchment pollutant concentrations for a given increment of discharged volume using a number of event pollutographs. Non-parametric statistics are then used to establish the characteristic pollutograph by pooling statistically indifferent runoff increments (known as slices) together. This allows the identification of the catchment's initial and background pollutant concentrations and for quantification of the first flush volume and its strength. The novel technique was used on seven catchments around Melbourne, Australia, with promising results. Sensitivity to the chosen increment of runoff (for which mean concentrations are calculated) indicated that when dealing with discrete flow-weighted water quality data, a suitable slice size should closely match the flow-weighting of samples. The overall sensitivity to runoff increment and level of significance was found to be negligible. Further research is needed to fully develop this method. Copyright (c) 2010 Elsevier Ltd. All rights reserved.

  3. Mechanisms affecting water quality in an intermittent piped water supply.

    PubMed

    Kumpel, Emily; Nelson, Kara L

    2014-01-01

    Drinking water distribution systems throughout the world supply water intermittently, leaving pipes without pressure between supply cycles. Understanding the multiple mechanisms that affect contamination in these intermittent water supplies (IWS) can be used to develop strategies to improve water quality. To study these effects, we tested water quality in an IWS system with infrequent and short water delivery periods in Hubli-Dharwad, India. We continuously measured pressure and physicochemical parameters and periodically collected grab samples to test for total coliform and E. coli throughout supply cycles at 11 sites. When the supply was first turned on, water with elevated turbidity and high concentrations of indicator bacteria was flushed out of pipes. At low pressures (<10 psi), elevated indicator bacteria were frequently detected even when there was a chlorine residual, suggesting persistent contamination had occurred through intrusion or backflow. At pressures between 10 and 17 psi, evidence of periodic contamination suggested that transient intrusion, backflow, release of particulates, or sloughing of biofilms from pipe walls had occurred. Few total coliform and no E. coli were detected when water was delivered with a chlorine residual and at pressures >17 psi.

  4. Design of a unit to produce hot distilled water for the same power consumption as a water heater

    NASA Technical Reports Server (NTRS)

    Bambenek, R. A.; Nuccio, P. P.

    1973-01-01

    Unit recovers 97% of water contained in pretreated waste water. Some factors are: cleansing agent prevents fouling of heat transfer surface by highly concentrated waste; absence of dynamic seals reduces required purge gas flow rate; and recycle loop maintains constant flushing process to carry cleansing agent across evaporation surface.

  5. Plumbing system shock absorbers as a source of Legionella pneumophila.

    PubMed

    Memish, Z A; Oxley, C; Contant, J; Garber, G E

    1992-12-01

    Water distribution systems have been demonstrated to be a major source of nosocomial legionellosis. We describe an outbreak in our institution in which a novel source of Legionella pneumophila was identified in the plumbing system. After an outbreak of 10 cases of legionellosis in our hospital, recommended measures including superheating of the hot water to 80 degrees C, hyperchlorination to 2 ppm, and flushing resulted in no new cases in the following 5 years. Recently, despite these control measures, three new cases occurred. Surveillance cultures of shower heads and water tanks were negative; cultures of tap water samples remained positive. This prompted a search for another reservoir. Shock absorbers installed within water pipes to decrease noise were suspected. One hundred twenty-five shock absorbers were removed and cultured. A total of 13 (10%) yielded heavy growth of L. pneumophila (serogroup 1). Since their removal, no new cases have been found and the percentage of positive results of random tap water culture has dropped from 20% to 5%. This is the first report that identifies shock absorbers as a possible reservoir for L. pneumophila. We recommend that institutions with endemic legionellosis assess the water system for possible removal of shock absorbers.

  6. Tank 26F-2F Evaporator Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Adu-Wusu, K.

    2012-12-19

    Tank 26F supernate sample was sent by Savannah River Remediation to Savannah River National Laboratory for evaporation test to help understand the underlying cause of the recent gravity drain line (GDL) pluggage during operation of the 2F Evaporator system. The supernate sample was characterized prior to the evaporation test. The evaporation test involved boiling the supernate in an open beaker until the density of the concentrate (evaporation product) was between 1.4 to 1.5 g/mL. It was followed by filtering and washing of the precipitated solids with deionized water. The concentrate supernate (or concentrate filtrate), the damp unwashed precipitated solids, andmore » the wash filtrates were characterized. All the precipitated solids dissolved during water washing. A semi-quantitative X-ray diffraction (XRD) analysis on the unwashed precipitated solids revealed their composition. All the compounds with the exception of silica (silicon oxide) are known to be readily soluble in water. Hence, their dissolution during water washing is not unexpected. Even though silica is a sparingly water-soluble compound, its dissolution is also not surprising. This stems from its small fraction in the solids as a whole and also its relative freshness. Assuming similar supernate characteristics, flushing the GDL with water (preferably warm) should facilitate dissolution and removal of future pluggage events as long as build up/aging of the sparingly soluble constituent (silica) is limited. On the other hand, since the amount of silica formed is relatively small, it is quite possible dissolution of the more soluble larger fraction will cause disintegration or fragmentation of the sparingly soluble smaller fraction (that may be embedded in the larger soluble solid mass) and allow its removal via suspension in the flushing water.« less

  7. Field survey of a sustainable sanitation system in a residential house.

    PubMed

    Nakagawa, Naoko; Otaki, Masahiro; Miura, Shinji; Hamasuna, Hironobu; Ishizaki, Katsuyoshi

    2006-01-01

    Sustainable sanitation is an approach for more ecological and sustainable water resources management. In this paper, we proposed one of the new integrated waste treatment systems: an "sustainable sanitation system" that includes separation of the black water from water system by a non-flushing toilet (bio-toilet), and a gray water treatment based on a biological and ecological concept. Sustainable sanitation system also converts the domestic waste to soil conditioners and fertilizers, for farmland use. As one of the case studies, Environmentally Symbiotic Housing in which people actually live using the bio-toilet for the black water treatment and the household wastewater treatment facility for the gray water was introduced. The availability of this system was investigated by analyzing the sawdust used in the bio-toilet and the quality of the effluent in the household wastewater treatment facility. As the result, the water content of the sawdust did not exceed 60% in any of the sampling points and the BOD and COD of the effluent of the household wastewater treatment facility were below 10 and 20 mg/L respectively, due to the low loading. Compared to the pollution load on the water environment created by the conventional system, it was found that the effluent of the house has a lower load than the tertiary treatment and the volume of the water consumption is 75% of the conventional system.

  8. Application of stormwater collected from porous asphalt pavements for non-potable uses in buildings.

    PubMed

    Hammes, Gabriela; Thives, Liseane Padilha; Ghisi, Enedir

    2018-09-15

    This study assessed the potential for potable water savings in a building by using stormwater filtered by a porous asphalt pavement located in a parking lot. Stormwater is meant to be used for non-potable purposes (flushing toilets and urinals). Two models of porous pavement systems were constructed, both with porous asphalt mixture over a different combination of porous granular layers. The models were assessed for their filtering capacity; samples of stormwater runoff were collected in a parking lot located near the building where filtered stormwater is meant to be used. The models showed to be capable of filtering some pollutants. However, additional water treatment would be necessary to obtain the quality required for non-potable uses. Then one model was selected for a theoretical analysis on using it in a parking lot. The potential for potable water savings was analysed considering four scenarios as a function of daily local rainfall data. The thickness of the temporary stormwater reservoir layer was calculated in order to meet the design rainfall adopted, and the stormwater tank capacity was estimated using the Netuno computer programme. As a result, using a 45,000-litre stormwater tank, potable water savings of at least 53% would be obtained if filtered stormwater were used to flush toilets and urinals. This indicates that porous pavements show a great potential for filtering stormwater runoff to be used in buildings. Copyright © 2018 Elsevier Ltd. All rights reserved.

  9. Potential and timescales for oxygen depletion in coastal upwelling systems: A box-model analysis

    NASA Astrophysics Data System (ADS)

    Harrison, C. S.; Hales, B.; Siedlecki, S.; Samelson, R. M.

    2016-05-01

    A simple box model is used to examine oxygen depletion in an idealized ocean-margin upwelling system. Near-bottom oxygen depletion is controlled by a competition between flushing with oxygenated offshore source waters and respiration of particulate organic matter produced near the surface and retained near the bottom. Upwelling-supplied nutrients are consumed in the surface box, and some surface particles sink to the bottom where they respire, consuming oxygen. Steady states characterize the potential for hypoxic near-bottom oxygen depletion; this potential is greatest for faster sinking rates, and largely independent of production timescales except in that faster production allows faster sinking. Timescales for oxygen depletion depend on upwelling and productivity differently, however, as oxygen depletion can only be reached in meaningfully short times when productivity is rapid. Hypoxia thus requires fast production, to capture upwelled nutrients, and fast sinking, to deliver the respiration potential to model bottom waters. Combining timescales allows generalizations about tendencies toward hypoxia. If timescales of sinking are comparable to or smaller than the sum of those for respiration and flushing, the steady state will generally be hypoxic, and results indicate optimal timescales and conditions exist to generate hypoxia. For example, the timescale for approach to hypoxia lengthens with stronger upwelling, since surface particle and nutrient are shunted off-shelf, in turn reducing subsurface respiration and oxygen depletion. This suggests that if upwelling winds intensify with climate change the increased forcing could offer mitigation of coastal hypoxia, even as the oxygen levels in upwelled source waters decline.

  10. Vacuum Flushing of Sewer Solids

    EPA Science Inventory

    The vacuum sewer and tank cleaning (flushing) technology removes sewer solids from urban drainage systems, such as storage tanks and pipes. This technology is both effective and inexpensive. In addition, it can be considered a true green technology. It operates under atmospheri...

  11. SEWER AND TANK SEDIMENT FLUSHING: CASE STUDIES

    EPA Science Inventory

    The objective of the report summarized here is to demonstrate that sewer system and storage tank flushing that reduces sediment deposition and accumulation is of prime importance to optimizing performance, maintaining structural integrity, and minimizing pollution of receiving wa...

  12. Effects of salinity and flooding on seedlings of cabbage palm (Sabal palmetto).

    PubMed

    Perry, L; Williams, K

    1996-03-01

    Sabal palmetto (Walt.) Lodd. ex Schultes (cabbage palm) dominates the coastal limit of many forests in North Florida and Georgia, United States. Changes in saltwater flooding due to sea level rise have been credicted with pushing the coastal limit of cabbage palms inland, eliminating regeneration before causing death of mature trees. Localized freshwater discharge along the coast causes different forest stands to experience tidal flooding with waters that differ in salinity. To elucidate the effect of such variation on regeneration failure under tidal flooding, we examined relative effects of flooding and salinity on the performance of cabbage palm seedlings. We examined the relationship between seedling establishment and degree of tidal inundation in the field, compared the ability of seedlings to withstand tidal flooding at two coastal sites that differed in tidal water salinity, and investigated the physiological responses of cabbage palm seedlings to salinity and flooding in a factorial greenhouse experiment. Seedling survival was inversely correlated with depth and frequency of tidal flooding. Survival of seedlings at a coastal site flooded by waters low in salinity [c. 3 parts per thousand (ppt)] was greater than that at a site flooded by waters higher in salinity (up to 23 ppt). Greenhouse experiments revealed that leaves of seedlings in pots flushed twice daily with salt solutions of 0 ppt and 8 ppt exhibited little difference in midmorning net CO 2 assimilation rates; those flushed with solutions of 15 ppt and 22 ppt, in contrast, had such low rates that they could not be detected. Net CO 2 assimilation rates also declined with increasing salinity for seedlings in pots that were continuously inundated. Continuous root zone inundation appeared to ameliorate effects of salinity on photosynthesis, presumably due to increased salt concentrations and possibly water deficits in periodically flushed pots. Such problems associated with periodic flushing by salt water may play a role in the mortality of cabbage palm seedlings in the field. The salinity range in which plant performance plummeted in the greenhouse was consistent with the salinity difference found between our two coastal study sites, suggesting that variation in tidal water salinity along the coast plays an important role in the ability of cabbage palm seedlings to withstand tidal flooding.

  13. Nitrogen and phosphorus transport between Fourleague Bay, LA, and the Gulf of Mexico: The role of winter cold fronts and Atchafalaya River discharge

    USGS Publications Warehouse

    Perez, B.C.; Day, J.W.; Justic, D.; Twilley, R.R.

    2003-01-01

    Nutrient fluxes were measured between Fourleague Bay, a shallow Louisiana estuary, and the Gulf of Mexico every 3 h between February 1 and April 30, 1994 to determine how high velocity winds associated with cold fronts and peak Atchafalaya River discharge influenced transport. Net water fluxes were ebb-dominated throughout the study because of wind forcing and high volumes of water entering the northern Bay from the Atchafalaya River. Flushing time of the Bay averaged <8 days; however, more rapid flushing occurred in response to northerly winds with approximately 56% of the volume of the Bay exported to the Gulf in 1 day during the strongest flushing event. Higher nitrate + nitrite (NO2+ NO3), total nitrogen (TN), and total phosphorus (TP) concentrations were indicative of Atchafalaya River input and fluxes were greater when influenced by high velocity northerly winds associated with frontal passage. Net exports of NO2 + NO3, TN, and TP were 43.5, 98.5, and 13.6 g s-1, respectively, for the 89-day study. An average of 10.6 g s-1 of ammonium (NH4) was exported to the Gulf over the study; however, concentrations were lower when associated with riverine influence and wind-driven exports suggesting the importance of biological processes. Phosphate (PO4) fluxes were nearly balanced over the study with fairly stable concentrations indicating a well-buffered system. The results indicate that the high energy subsidy provided by natural pulsing events such as atmospheric cold fronts and seasonal river discharge are efficient mechanisms of nutrient delivery to adjacent wetlands and nearshore coastal ecosystems and are important in maintaining coastal sustainability. ?? 2003 Elsevier Ltd. All rights reserved.

  14. The origin of high-nitrate ground waters in the Australian arid zone

    NASA Astrophysics Data System (ADS)

    Barnes, C. J.; Jacobson, G.; Smith, G. D.

    1992-08-01

    Nitrate concentrations beyond the drinking-water limit of 10 mg1 -1 NO 3-N, are common in Australian arid-zone ground waters and are often associated with otherwise potable waters. In some aquifers nitrate-N concentrations of up to 80 mg1 -1 have been found, and this is a severe constraint on water supply development for small settlements. Water-bore data indicate a correlation of high-nitrate ground waters with shallow unconfined aquifers. Aguifer hydrochemistry indicats that these ground waters were emplaced by episodic Holocene recharge events in an otherwise arid climate regime. Nitrate has been flushed through the unsaturated zone which apparently lacks denitrification activity. The nitrate originates by near-surface biological fixation and contributing organisms include cyanobacteria in soil crusts and bacteria in termite mounds with the highest soil nitrate concentrations found in the outer skin of termite mounds. Bacteria associated with the termites appear to fix nitrogen, which eventually appears in an inorganic form, principally as ammonia. Nitrate is produced by bacterial oxidation of the ammonia, and is leached to the outside of the termite mound by capillary action. Diffuse recharge from extreme rainfall events then flushes this nitrate to the water table.

  15. Stormflow hydrochemistry of a river draining an abandoned metal mine: the Afon Twymyn, central Wales.

    PubMed

    Byrne, Patrick; Reid, Ian; Wood, Paul J

    2013-03-01

    Contaminated drainage from metal mines is a serious water-quality problem facing nations that exploit metal mineral resources. Measurements of river hydrochemistry during baseflow are common at mine sites, whilst detailed hydrochemical information regarding stormflow is limited and often confined to a single event. This study investigates the seasonal evolution of stormflow hydrochemistry at an abandoned metal mine in central Wales, UK, and the possible sources and mechanisms of metal release. Significant flushing of metals was observed during stormflow events, resulting in concentrations that severely exceeded water-quality guidelines. The relationship between metal concentrations and river discharge suggests dissolution of efflorescent metal sulphates on the surface of the mine spoil as the principal source of the contamination. High fluxes of Pb during stormflows are linked to extended periods of dry weather prior to storm events that produced water table drawdown and encouraged oxidation of Pb sulphide in the mine spoil. However, some Pb flushing also occurred following wet antecedent conditions. It is suggested that Fe oxide reduction in mine spoil and translatory flows involving metal-rich pore waters results in flushing during wetter periods. Detailed measurements of stormflow hydrochemistry at mine sites are essential for accurate forecasting of long-term trends in metals flux to understand metal sources and mechanisms of release, to assess potential risks to water quality and instream ecology, and to gauge the potential effectiveness of remediation. In order to protect riverine and riparian ecosystems, it is suggested that routine monitoring of stormflows becomes part of catchment management in mining-impacted regions.

  16. Relationship between the transmission of schistosomiasis japonica and the construction of the Three Gorge Reservoir.

    PubMed

    Zheng, Jiang; Gu, Xue-guang; Xu, Yong-long; Ge, Ji-hua; Yang, Xian-xiang; He, Chang-hao; Tang, Chao; Cai, Kai-ping; Jiang, Qing-wu; Liang, You-sheng; Wang, Tian-ping; Xu, Xing-jian; Zhong, Jiu-he; Yuan, Hong-chang; Zhou, Xiao-nong

    2002-05-01

    To study the relationship between the changes of environment and the transmission of Schistosomiasis japonica after the construction of the Three Gorge Reservoir. On the basis of the predictive data on changes of water level and sediment in the middle and lower reaches of the Yangtze River after the dam construction provided by the Yangtze River Committee on Water Conservancy, corresponding data were collected and analyzed. In order to understand the effects of changes of water level and sediment on Oncomelania hupensis, the intermediate host of Schistosoma japonicum, field surveys and ecologically intimated experiments were done. The prevalence status and factors related to transmission were investigated by epidemiology, medical geography and public health. Positive impact on control of schistosomiasis is that floods in the Yangtze River will occur less and will decrease the dispersal of snails and the chances of infection for humans and animals as well. Snail habitats' beach will be reduced in the flushed area along the Yangtze River. Exploitation of beach and elimination of snails will benefit from the beach's uplift in flushed area. The floods ahead of time in autumn will interfere with the development of snails. Negative impact is that the flushed beaches and migratory settlements at certain altitude may become snail habitats. So the reservoir area will be a potential transmission area of schistosomiasis due to dispersal of infectious resources and Oncomelania snails. The uprising of the water body level may cause the expending of the snail habitats in some places of Jianghan plain during the transition of spring to summer. The destruction of the embankments of the Dongting Lake will be put off by its delayed flush, which causes the beach in a situation of growing reed-grass or grass for a long time that benefits the reproduction of the snails. The chances for schistosome infection to humans and animals will be on the increase, because the water regression occurs ahead of time in the Dongting Lake beach in autumn. The distribution of snails will not be affected by the changes of water level in the lower reaches of the Yangtze River after the dam is built, but the flushed section in Anhui in the recent 80 years are suitable for the snails' development. The environmental changes due to dam construction will not obviously affect the development of snails and the transmission of schistosomiasis in the Poyang Lake area. The construction of the huge dam and the formation of the Three Gorge Reservoir on the Yangtze River may have both positive and negative impact on schistosomiasis transmission and control. Great effort must be made to decrease the negative impact to avoid or, at least, to decrease S. japonicum transmission.

  17. Transport dynamics in a sheltered estuary and connecting tidal straits: SF6 tracer study in New York Harbor.

    PubMed

    Caplow, Theodore; Schlosser, Peter; Ho, David T; Santella, Nicholas

    2003-11-15

    In July 2002, approximately 0.9 mol of sulfur hexafluoride (SF6) was injected into Newark Bay, NJ, a 14 km2 estuary that forms part of New York Harbor, to investigate circulation, mixing, and the transport and fate of solutes. The SF6 tracer was observed over 11 consecutive days using a high-resolution measurement system. Total tracer mass in the sheltered waters declined quasiexponentially at a rate of 0.29 +/- 0.03 d(-1). Air-water gas exchange was estimated to account for 56% of tracer mass loss, upon the basis of wind speed/gas exchange parametrizations. Large-scale tidal transfer of solutes through the Kill van Kull strait (7 km long) caused net seaward flushing contrary to the apparent residual circulation. Seaward transport via the Arthur Kill strait (20 km long) appeared to depend on longitudinal dispersion, residual circulation, and freshwater discharge and was approximately 1 order of magnitude lower. The loss rate due to flushing alone was 0.13 +/- 0.02 d(-1), indicating a mean residence time for water and solutes in Newark Bay of approximately 8 days (without gas exchange). The experiment provides direct visualization of the transport of a released contaminant, and suggests a relationship between the length and configuration of tidal straits and related transport of solutes.

  18. Modeling non-steady state radioisotope transport in the vadose zone--A case study using uranium isotopes at Pena Blanca, Mexico

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ku, T. L.; Luo, S.; Goldstein, S. J.

    2009-06-01

    Current models using U- and Th-series disequilibria to study radioisotope transport in groundwater systems mostly consider a steady-state situation. These models have limited applicability to the vadose zone (UZ) where the concentration and migratory behavior of radioisotopes in fluid are often transitory. We present here, as a first attempt of its kind, a model simulating the non-steady state, intermittent fluid transport in vadose layers. It provides quantitative constraints on in-situ migration of dissolved and colloidal radioisotopes in terms of retardation factor and rock-water interaction (or water transit) time. For uranium, the simulation predicts that intermittent flushing in the UZ leadsmore » to a linear relationship between reciprocal U concentration and {sup 234}U/{sup 238}U ratio in percolating waters, with the intercept and slope bearing information on the rates of dissolution and {alpha}-recoil of U isotopes, respectively. The general validity of the model appears to be borne out by the measurement of uranium isotopes in UZ waters collected at various times over a period during 1995-2006 from a site in the Pena Blanca mining district, Mexico, where the Nopal I uranium deposit is located. Enhanced {sup 234}U/{sup 238}U ratios in vadose-zone waters resulting from lengthened non-flushing time as prescribed by the model provide an interpretative basis for using {sup 234}U/{sup 238}U in cave calcites to reconstruct the regional changes in hydrology and climate. We also provide a theoretical account of the model's potential applications using radium isotopes.« less

  19. Modeling non-steady state radioisotope transport in the vadose zone - A case study using uranium isotopes at Peña Blanca, Mexico

    NASA Astrophysics Data System (ADS)

    Ku, T. L.; Luo, S.; Goldstein, S. J.; Murrell, M. T.; Chu, W. L.; Dobson, P. F.

    2009-10-01

    Current models using U- and Th-series disequilibria to study radioisotope transport in groundwater systems mostly consider a steady-state situation. These models have limited applicability to the vadose zone (UZ) where the concentration and migratory behavior of radioisotopes in fluid are often transitory. We present here, as a first attempt of its kind, a model simulating the non-steady state, intermittent fluid transport in vadose layers. It provides quantitative constraints on in-situ migration of dissolved and colloidal radioisotopes in terms of retardation factor and rock-water interaction (or water transit) time. For uranium, the simulation predicts that intermittent flushing in the UZ leads to a linear relationship between reciprocal U concentration and 234U/ 238U ratio in percolating waters, with the intercept and slope bearing information on the rates of dissolution and α-recoil of U isotopes, respectively. The general validity of the model appears to be borne out by the measurement of uranium isotopes in UZ waters collected at various times over a period during 1995-2006 from a site in the Peña Blanca mining district, Mexico, where the Nopal I uranium deposit is located. Enhanced 234U/ 238U ratios in vadose-zone waters resulting from lengthened non-flushing time as prescribed by the model provide an interpretative basis for using 234U/ 238U in cave calcites to reconstruct the regional changes in hydrology and climate. We also provide a theoretical account of the model's potential applications using radium isotopes.

  20. Spatially Estimating Disturbance of Harbor Seals (Phoca vitulina)

    PubMed Central

    Jansen, John K.; Brady, Gavin M.; Ver Hoef, Jay M.; Boveng, Peter L.

    2015-01-01

    Tidewater glacial fjords in Alaska provide habitat for some of the largest aggregations of harbor seals (Phoca vitulina), with calved ice serving as platforms for birthing and nursing pups, molting, and resting. These fjords have also been popular destinations for tour ships for more than a century, with dramatic increases in vessel traffic since the 1980s. Seals on ice are known to flush into the water when approached by tour ships, but estimating the exposure to disturbance across populations is difficult. Using aerial transect sampling while simultaneously tracking vessel movements, we estimated the spatial overlap between seals on ice and cruise ships in Disenchantment Bay, Alaska, USA. By integrating previously estimated rates of disturbance as a function of distance with an ‘intensity surface’ modeled spatially from seal locations in the surveys, we calculated probabilities of seals flushing during three separate ship visits. By combining our estimate of seals flushed with a modeled estimate of the total fjord population, we predict that up to 14% of the seals (up to 11% of pups) hauled out would have flushed into the water, depending on the route taken by ships relative to seal aggregations. Such high potential for broad-scale disturbance by single vessels (when up to 4 ships visit per day) was unexpected and underscores the need to 1) better understand long-term effects of disturbance; 2) regularly monitor populations exposed to high vessel traffic; and 3) develop conservation measures to reduce seal-ship overlap. PMID:26132083

  1. Water-Cooled Optical Thermometer

    NASA Technical Reports Server (NTRS)

    Menna, A. A.

    1987-01-01

    Water-cooled optical probe measures temperature of nearby radiating object. Intended primarily for use in silicon-growing furnace for measuring and controlling temperatures of silicon ribbon, meniscus, cartridge surfaces, heaters, or other parts. Cooling water and flushing gas cool fiber-optic probe and keep it clean. Fiber passes thermal radiation from observed surface to measuring instrument.

  2. 29 CFR 1910.253 - Oxygen-fuel gas welding and cutting.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... prohibited in outside generator houses or inside generator rooms. (D) Water shall not be supplied through a... chamber shall always be flushed out with water, renewing the water supply in accordance with the.... Workmen in charge of the oxygen or fuel-gas supply equipment, including generators, and oxygen or fuel-gas...

  3. Removal of chloride from MSWI fly ash.

    PubMed

    Chen, Wei-Sheng; Chang, Fang-Chih; Shen, Yun-Hwei; Tsai, Min-Shing; Ko, Chun-Han

    2012-10-30

    The high levels of alkali chloride and soluble metal salts present in MSWI fly ash is worth noting for their impact on the environment. In addition, the recycling or reuse of fly ash has become an issue because of limited landfill space. The chloride content in fly ash limits its application as basis for construction materials. Water-soluble chlorides such as potassium chloride (KCl), sodium chloride (NaCl), and calcium chloride hydrate (CaCl(2) · 2H(2)O) in fly ash are easily washed away. However, calcium chloride hydroxide (Ca(OH)Cl) might not be easy to leach away at room temperature. The roasting and washing-flushing processes were applied to remove chloride content in this study. Additionally, air and CO(2) were introduced into the washing process to neutralize the hazardous nature of chlorides. In comparison with the water flushing process, the roasting process is more efficient in reducing the process of solid-liquid separation and drying for the reuse of Cl-removed fly ash particles. In several roasting experiments, the removal of chloride content from fly ash at 1050°C for 3h showed the best results (83% chloride removal efficiency). At a solid to liquid ratio of 1:10 the water-flushing process can almost totally remove water-soluble chloride (97% chloride removal efficiency). Analyses of mineralogical change also prove the efficiency of the fly ash roasting and washing mechanisms for chloride removal. Copyright © 2012 Elsevier B.V. All rights reserved.

  4. Simulation of tidal-flow, circulation, and flushing of the Charlotte Harbor Estuarine System, Florida

    USGS Publications Warehouse

    Goodwin, C.R.

    1996-01-01

    A two-dimensional circulation and constituent- transport model, SIMSYS2D, was used to simulate tidal-flow, circulation, and flushing characteristics in Charlotte Harbor. The model was calibrated and verified against field observations of stage,discharge, and velocity. Standard errors averaged about 3 percent of the range in stage at the tide stations and between 3 and 10 percent of the range in discharge measured in the inlets for the calibration period. Following calibration and verification, the model was applied to three different conditions. The first condition represented the existing physical configuration and typical freshwater inflow. The second condition represented reduced fresh water inflow, and the third represented an alteration of Sanibel Causeway. All three conditions were evaluated through Lagrangian particle tracks and simulated dye injections. Residual circulation patterns were similar for typical and reduced freshwater inflow, but reduced freshwater inflow increased the residence time in the upper harbor by a factor of two or more. Removal of Sanibel Causeway did not significantly affect residual flows in upper and lower Charlotte Harbor, Matlacha Pass, Gasparilla Sound, or the Gulf of Mexico. Analysis of Lagrangian particle tracks indicated changes in residence times in San Carlos Bay as a result of removing Sanibel Causeway, but the changes were not consistent for all particles. The residence time of 8 particles in San Carlos Bay decreased with removal of the causeway, 1 was unchanged, and the residence time of 3 particles increased. Simulated flushing characteristics of the estuarine system were affected more by reduced freshwater inflow than for typical freshwater inflow. After 30 days of simulation of reduced freshwater inflow, 42 percent of the dye injected into the upper harbor remained in the upper harbor, compared to 28 percent for typical freshwater inflow. The upper harbor has a relatively long flushing time because it is not directly connected to the gulf and some of the dye that exits to the lower harbor returns to the upper harbor by way of a landward residual flow in the deep center channel. The upper harbor is also sensitive to reduced freshwater inflow because it is the subarea closest to freshwater inflow from the Peace and Myakka Rivers. Removal of Sanibel Causeway had a slight effect on the flushing of Pine Island Sound and San Carlos Bay, but had no significant effect in upper and lower Charlotte Harbor.

  5. METHOD OF CHEMICAL DECONTAMINATION OF STAINLESS STEEL NUCLEAR FACILITIES

    DOEpatents

    Pancer, G.P.; Zegger, J.L.

    1961-12-19

    A chemical method is given for removing activated corrosion products on the primary system surfaces of a pressurized water reactor. The corrosion product deposits are composed chiefly of magnetite (Fe/sub 3/O/sub 4/) with small amounts of nickel and chromium oxides. The corroded surfaces are first flushed with a caustic permanganate primary solution consisting of sodium hydroxide and potassium permanganate followed by a secondary rinse solution of ammonium citrate and citric acid containing the complexing agent Versene in small amounts. Demineralized water is used to clean out the primary and secondary solutions and a 60-minute drying period precedes the rinse solution. (AEC)

  6. Vacuum Flushing of Sewer Solids (Slides)

    EPA Science Inventory

    The vacuum sewer and tank cleaning (flushing) technology removes sewer solids from urban drainage systems, such as storage tanks and pipes. This technology is both effective and inexpensive. In addition, it can be considered a true green technology. It operates under atmospheri...

  7. FLUSHING FOR SEWER SEDIMENT, CORROSION, AND POLLUTION CONTROL

    EPA Science Inventory

    This presentation overviews causes of sewer deterioration and heavy pollutant discharges caused by rain events together with a discussion of their control methods. In particular, it covers in-sewer- and combined sewer overflow- (CSO-) storage-tank-flushing systems for removal of ...

  8. Biofilm formation in an experimental water distribution system: the contamination of non-touch sensor taps and the implication for healthcare.

    PubMed

    Moore, Ginny; Stevenson, David; Thompson, Katy-Anne; Parks, Simon; Ngabo, Didier; Bennett, Allan M; Walker, Jimmy T

    2015-01-01

    Hospital tap water is a recognised source of Pseudomonas aeruginosa. U.K. guidance documents recommend measures to control/minimise the risk of P. aeruginosa in augmented care units but these are based on limited scientific evidence. An experimental water distribution system was designed to investigate colonisation of hospital tap components. P. aeruginosa was injected into 27 individual tap 'assemblies'. Taps were subsequently flushed twice daily and contamination levels monitored over two years. Tap assemblies were systematically dismantled and assessed microbiologically and the effect of removing potentially contaminated components was determined. P. aeruginosa was repeatedly recovered from the tap water at levels above the augmented care alert level. The organism was recovered from all dismantled solenoid valves with colonisation of the ethylene propylene diene monomer (EPDM) diaphragm confirmed by microscopy. Removing the solenoid valves reduced P. aeruginosa counts in the water to below detectable levels. This effect was immediate and sustained, implicating the solenoid diaphragm as the primary contamination source.

  9. Economic viability and critical influencing factors assessment of black water and grey water source-separation sanitation system.

    PubMed

    Thibodeau, C; Monette, F; Glaus, M; Laflamme, C B

    2011-01-01

    The black water and grey water source-separation sanitation system aims at efficient use of energy (biogas), water and nutrients but currently lacks evidence of economic viability to be considered a credible alternative to the conventional system. This study intends to demonstrate economic viability, identify main cost contributors and assess critical influencing factors. A technico-economic model was built based on a new neighbourhood in a Canadian context. Three implementation scales of source-separation system are defined: 500, 5,000 and 50,000 inhabitants. The results show that the source-separation system is 33% to 118% more costly than the conventional system, with the larger cost differential obtained by lower source-separation system implementation scales. A sensitivity analysis demonstrates that vacuum toilet flow reduction from 1.0 to 0.25 L/flush decreases source-separation system cost between 23 and 27%. It also shows that high resource costs can be beneficial or unfavourable to the source-separation system depending on whether the vacuum toilet flow is low or normal. Therefore, the future of this configuration of the source-separation system lies mainly in vacuum toilet flow reduction or the introduction of new efficient effluent volume reduction processes (e.g. reverse osmosis).

  10. A simple bubbling system for measuring radon (222Rn) gas concentrations in water samples based on the high solubility of radon in olive oil.

    PubMed

    Al-Azmi, D; Snopek, B; Sayed, A M; Domanski, T

    2004-01-01

    Based on the different levels of solubility of radon gas in organic solvents and water, a bubbling system has been developed to transfer radon gas, dissolving naturally in water samples, to an organic solvent, i.e. olive oil, which is known to be a good solvent of radon gas. The system features the application of a fixed volume of bubbling air by introducing a fixed volume of water into a flask mounted above the system, to displace an identical volume of air from an air cylinder. Thus a gravitational flow of water is provided without the need for pumping. Then, the flushing air (radon-enriched air) is directed through a vial containing olive oil, to achieve deposition of the radon gas by another bubbling process. Following this, the vial (containing olive oil) is measured by direct use of gamma ray spectrometry, without the need of any chemical or physical processing of the samples. Using a standard solution of 226Ra/222Rn, a lowest measurable concentration (LMC) of radon in water samples of 9.4 Bq L(-1) has been achieved (below the maximum contaminant level of 11 Bq L(-1)).

  11. Real-time electronic monitoring of a pitted and leaking gas gathering pipeline

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Asperger, R.G.; Hewitt, P.G.

    1986-08-01

    Hydrogen patch, flush electrical resistance, and flush linear polarization proves wre used with flush coupons to monitor corrosion rates in a pitted and leaking sour gas gathering line. Four inhibitors were evaluated in stopping the leaks. Inhibitor residuals and the amount and ratio of water and condensate in the lines were measured at five locations along the line. The best inhibitor reduced reduced the pit-leak frequency by over a factor of 10. Inhibitor usage rate was optimized using the hydrogen patch current as a measure of the instantaneous corrosion rate. Improper pigging was identified as a cause of corrosion transients.more » This problem is discussed in relation to the pigging of pipelines in stratified flow where moving fluids are the carriers for continuously injected corrosion inhibitors.« less

  12. Water quantity and quality model for the evaluation of water-management strategies in the Netherlands: application to the province of Friesland

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brinkman, J.J.; Griffioen, P.S.; Groot, S.

    1987-03-01

    The Netherlands have a rather complex water-management system consisting of a number of major rivers, canals, lakes and ditches. Water-quantity management on a regional scale is necessary for an effective water-quality policy. To support water management, a computer model was developed that includes both water quality and water quantity, based on three submodels: ABOPOL for the water movement, DELWAQ for the calculation of water quality variables and BLOOM-II for the phytoplankton growth. The northern province of Friesland was chosen as a test case for the integrated model to be developed, where water quality is highly related to the water distributionmore » and the main trade-off is minimizing the intake of (eutrophicated) alien water in order to minimize external nutrient load and maximizing the intake in order to flush channels and lakes. The results of the application of these models to this and to a number of hypothetical future situations are described.« less

  13. FLUSHING FOR SEWER SEDIMENT, CORROSION, AND POLLUTION CONTROL

    EPA Science Inventory

    This paper overviews causes of combined-sewer deterioration and their heavy pollutant discharges caused by rain events together with a discussion of their control methods. In particular, it covers in-sewer and combined-sewer overflow (CSO) storage-tank-flushing systems for removi...

  14. FLUSH - PREDICTION OF FLOW PARAMETERS OF SLUSH HYDROGEN

    NASA Technical Reports Server (NTRS)

    Hardy, T.

    1994-01-01

    Slush hydrogen, a mixture of the solid and liquid phases of hydrogen, is a possible source of fuel for the National Aerospace Plane (NASP) Project. Advantages of slush hydrogen over liquid hydrogen include greater heat capacity and greater density. However, practical use of slush hydrogen as a fuel requires systems of lines, valves, etc. which are designed to deliver the fuel in slush form with minimal solid loss as a result of pipe heating or flow friction. Engineers involved with the NASP Project developed FLUSH to calculate the pressure drop and slush hydrogen solid fraction loss for steady-state, one-dimensional flow. FLUSH solves the steady-state, one-dimensional energy equation and the Bernoulli equation for pipe flow. The program performs these calculations for each two-node element--straight pipe length, elbow, valve, fitting, or other part of the piping system--specified by the user. The user provides flow rate, upstream pressure, initial solid hydrogen fraction, element heat leak, and element parameters such as length and diameter. For each element, FLUSH first calculates the pressure drop, then figures the slush solid fraction exiting the element. The code employs GASPLUS routines to calculate thermodynamic properties for the slush hydrogen. FLUSH is written in FORTRAN IV for DEC VAX series computers running VMS. An executable is provided on the tape. The GASPLUS physical properties routines which are required for building the executable are included as one object library on the program media (full source code for GASPLUS is available separately as COSMIC Program Number LEW-15091). FLUSH is available in DEC VAX BACKUP format on a 9-track 1600 BPI magnetic tape (standard media) or on a TK50 tape cartridge. FLUSH was developed in 1989.

  15. Understanding the Flushing Capability of Bellingham Bay and Its Implication on Bottom Water Hypoxia

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Taiping; Yang, Zhaoqing

    2015-05-05

    In this study, an unstructured-grid finite-volume coastal ocean model (FVCOM) was used to simulate hydrodynamic circulation and assess the flushing capability in Bellingham Bay, Washington, USA. The model was reasonably calibrated against field observations for water level, velocity and salinity, and was further used to calculate residence time distributions in the study site. The model results suggest that, despite the large tidal ranges (~4 m during spring tide), tidal currents are relatively weak in Bellingham Bay with surface currents generally below 0.5 m/s. The local residence time in Bellingham Bay varies from to near zero to as long as 15more » days, depending on the location and river flow condition. In general, Bellingham Bay is a well-flushed coastal embayment affected by freshwater discharge, tides, wind, and density-driven circulation. The basin-wide global residence time ranges from 5-7 days. The model results also provide useful information on possible causes of the emerging summertime hypoxia problem in the north central region of Bellingham Bay. It was concluded that the formation of the bottom hypoxic water should result from the increased consumption rate of oxygen in the bottom oceanic inflow with low dissolved oxygen by organic matters accumulated at the regions characterized with relatively long residence time in summer months.« less

  16. Water quality, bed-sediment quality, and simulation of potential contaminant transport in Foster Creek, Berkeley County, South Carolina, 1991-93

    USGS Publications Warehouse

    Campbell, T.R.; Bower, D.E.

    1996-01-01

    Foster Creek, a freshwater tidal creek in Berkeley County, South Carolina, is located in an area of potential contaminant sources from residential, commercial, light industrial, and military activities. The creek is used as a secondary source of drinking water for the surrounding Charleston area. Foster Creek meets most of the freshwater- quality requirements of State and Federal regulatory agencies, but often contains low concentrations of dissolved oxygen and has been characterized as eutrophic. Investigations of water- and bed-sediment quality were made between 1991 and 1993 to assess the effects of anthropogenic sources of contamination on Foster Creek. Low-flow surface-water samples were generally free of toxic compounds with the exception of laboratory artifacts and naturally occurring trace metals. Storm-runoff samples generally contained very low concentrations (near detection limits) of a small number of volatile and semivolatile organics and naturally occurring trace metals. Concentrations of toxic compounds in excess of current (1995) South Carolina Department of Health and Environmental Control and U.S. Environmental Protection Agency regulations were not detected in surface-water samples collected from Foster Creek. Chemical analyses of streambed sediments indicated minimal anthropogenic effects on sediment quality. The particle-tracking option of the U.S. Geological Survey one-dimensional unsteady-flow model (BRANCH) indicated that as the simulated volume of rainfall runoff increased in the Foster Creek Basin, simulated particles in Foster Creek were transported greater distances. Simulating flow through the Bushy Park Dam (also known as Back River Dam) had little effect on particle movement in Foster Creek. Simulating typical withdrawal rates at a water-supply intake resulted in a slight attraction of particles toward the intake during conditions of relatively low runoff. These withdrawals had a greater influence on particles downstream of the intake than on those upstream of the intake. Simulations confirmed earlier findings which suggested that the creek would not flush during baseflow conditions, with the exception of the lower 1-mile reach, where flushing results from tidal movements. According to the simulations, Foster Creek will fully flush if a 2-year, 7-day storm occurs. Flushing appears to be affected more by the total volume of storm runoff than by typical municipal withdrawals or tidal effects.

  17. Performance of WVSS-II hygrometers on the FAAM Research Aircraft

    NASA Astrophysics Data System (ADS)

    Vance, A. K.; Abel, S. J.; Cotton, R. J.; Woolley, A. M.

    2014-08-01

    We compare the performance of five hygrometers fitted to the Facility for Airborne Atmospheric Measurement's (FAAM) BAe 146-301 research aircraft using data from approximately one hundred flights executed over the course of two years under a wide range of conditions. Bulk comparison of cloud free data show good agreement between chilled mirror hygrometers and a WVSS-II fed from a modified Rosemount inlet but that a WVSS-II fed from the standard flush inlet appears to over read compared to the other instruments, except at higher humidities. Statistical assessment of hygrometer performance in cloudy conditions is problematic due to the variable nature of clouds, so a number of case studies are used instead to investigate the performance of the hygrometers in sub optimal conditions. It is found that the flush inlet is not susceptible to either liquid or solid water but that the Rosemount inlet has a significant susceptibility to liquid water; it is not susceptible to ice. In all conditions the WVSS-II respond much more rapidly than the chilled mirror devices, with the flush inlet-fed WVSS-II being more rapid than that connected to the Rosemount.

  18. Performance of WVSS-II hygrometers on the FAAM research aircraft

    NASA Astrophysics Data System (ADS)

    Vance, A. K.; Abel, S. J.; Cotton, R. J.; Woolley, A. M.

    2015-03-01

    We compare the performance of five hygrometers fitted to the Facility for Airborne Atmospheric Measurement's (FAAM) BAe 146-301 research aircraft using data from approximately 100 flights executed over the course of 2 years under a wide range of conditions. Bulk comparison of cloud free data show good agreement between chilled mirror hygrometers and a WVSS-II fed from a modified Rosemount inlet, but that a WVSS-II fed from the standard flush inlet appears to over-read compared to the other instruments, except at higher humidities. Statistical assessment of hygrometer performance in cloudy conditions is problematic due to the variable nature of clouds, so a number of case studies are used instead to investigate the performance of the hygrometers in sub-optimal conditions. It is found that the flush inlet is not susceptible to either liquid or solid water but that the Rosemount inlet has a significant susceptibility to liquid water and may also be susceptible to ice. In all conditions the WVSS-II responds much more rapidly than the chilled mirror devices, with the flush inlet-fed WVSS-II being more rapid than that connected to the Rosemount.

  19. Influence of secondary water supply systems on microbial community structure and opportunistic pathogen gene markers.

    PubMed

    Li, Huan; Li, Shang; Tang, Wei; Yang, Yang; Zhao, Jianfu; Xia, Siqing; Zhang, Weixian; Wang, Hong

    2018-06-01

    Secondary water supply systems (SWSSs) refer to the in-building infrastructures (e.g., water storage tanks) used to supply water pressure beyond the main distribution systems. The purpose of this study was to investigate the influence of SWSSs on microbial community structure and the occurrence of opportunistic pathogens, the latter of which are an emerging public health concern. Higher numbers of bacterial 16S rRNA genes, Legionella and mycobacterial gene markers were found in public building taps served by SWSSs relative to the mains, regardless of the flushing practice (P < 0.05). In residential buildings, genes of L. pneumomhila, Acanthamoeba and Vermamoeba vermiformis were primarily detected in tanks and taps compared to the mains. Long water retention time, warm temperature and loss of disinfectant residuals promoted microbial growth and colonization of potential pathogens in SWSSs. Varied levels of microbial community shifts were found in different types of SWSSs during water transportation from the distribution main to taps, highlighting the critical role of SWSSs in shaping the drinking water microbiota. Overall, the results provided insight to factors that might aid in controlling pathogen proliferation in real-world water systems using SWSSs. Copyright © 2018 Elsevier Ltd. All rights reserved.

  20. AN EXPERIMENTAL STUDY OF COMPLETE DISSOLUTION OF A NONAQUEOUS PHASE LIQUID IN SATURATED POROUS MEDIA

    EPA Science Inventory

    The attenuation of gamma radiation was utilized to measure changing residual trichloroethylene (TCE) saturation in an otherwise water-saturated porous medium as clean water was flushed through the medium. A front over which dissolution actively occurred was observed. Once develop...

  1. SEWER AND TANK FLUSHING FOR CORROSION AND POLLUTION CONTROL

    EPA Science Inventory

    This paper presents an overview of the causes of sewer deterioration and control methods that can prevent or arrest this deterioration. articular, the paper addresses the use of inline- and combined sewer overflow (CSO) storage tank-flushing systems for removing sediments and mi...

  2. SEWER AND TANK FLUSHING FOR SEDIMENT, CORROSION AND POLLUTION CONTROL

    EPA Science Inventory

    This paper presents an overview of causes of sewer deterioration together with a discussion of control methods that can prevent or arrest this deterioration. In particular, the paper covers inline- and combined sewer overflow- (CSO) storage-tank-flushing systems for removal of se...

  3. Gas flushing through hyper-acidic crater lakes: the next steps within a reframed monitoring time window

    NASA Astrophysics Data System (ADS)

    Rouwet, Dmitri

    2016-04-01

    Tracking variations in the chemical composition, water temperature and pH of brines from peak-activity crater lakes is the most obvious way to forecast phreatic activity. Volcano monitoring intrinsically implies a time window of observation that should be synchronised with the kinetics of magmatic processes, such as degassing and magma intrusion. To decipher "how much time ago" a variation in degassing regime actually occurred before eventually being detected in a crater lake is key, and depends on the lake water residence time. The above reasoning assumes that gas is preserved as anions in the lake water (SO4, Cl, F anions), in other words, that scrubbing of acid gases is complete and irreversible. Less is true. Recent work has confirmed, by direct MultiGas measurement from evaporative plumes, that even the strongest acid in liquid medium (i.e. SO2) degasses from hyper-acidic crater lakes. The less strong acid HCl has long been recognised as being more volatile than hydrophyle in extremely acidic solutions (pH near 0), through a long-term steady increase in SO4/Cl ratios in the vigorously evaporating crater lake of Poás volcano. We now know that acidic gases flush through hyper-acidic crater lake brines, but we don't know to which extend (completely or partially?), and with which speed. The chemical composition hence only reflects a transient phase of the gas flushing through the lake. In terms of volcanic surveillance this brings the advantage that the monitoring time window is definitely shorter than defined by the water chemistry, but yet, we do not know how much shorter. Empirical experiments by Capaccioni et al. (in press) have tried to tackle this kinetic problem for HCl degassing from a "lab-lake" on the short-term (2 days). With this state of the art in mind, two new monitoring strategies can be proposed to seek for precursory signals of phreatic eruptions from crater lakes: (1) Tracking variations in gas compositions, fluxes and ratios between species in evaporative degassing plumes can be useful as monitoring tool on the short-term, but only if the underlying process of gas flushing through acidic lakes is better understood, and linked with the lake water chemistry; (2) The second method forgets about chemical kinetics, degassing models and dynamics of phreatic eruptions, and sticks to the classical principle in geology of "the past is the key for the future". How did lake chemistry parameters vary during the various stages of unrest and eruption, on a purely mathematical basis? Can we recognise patterns in the numerical values related to the changes in volcanic activity? Water chemistry only as a monitoring tool for extremely dynamic and erupting crater lake systems, is inefficient in revealing short-term precursors for single phreatic eruptions, within the current perspective of the residence time dependent monitoring time window. The monitoring rules established since decades based only on water chemistry have thus somehow become obsolete and need revision.

  4. Health risks from exposure to Legionella in reclaimed water aerosols: Toilet flushing, spray irrigation, and cooling towers.

    PubMed

    Hamilton, Kerry A; Hamilton, Mark T; Johnson, William; Jjemba, Patrick; Bukhari, Zia; LeChevallier, Mark; Haas, Charles N

    2018-05-01

    The use of reclaimed water brings new challenges for the water industry in terms of maintaining water quality while increasing sustainability. Increased attention has been devoted to opportunistic pathogens, especially Legionella pneumophila, due to its growing importance as a portion of the waterborne disease burden in the United States. Infection occurs when a person inhales a mist containing Legionella bacteria. The top three uses for reclaimed water (cooling towers, spray irrigation, and toilet flushing) that generate aerosols were evaluated for Legionella health risks in reclaimed water using quantitative microbial risk assessment (QMRA). Risks are compared using data from nineteen United States reclaimed water utilities measured with culture-based methods, quantitative PCR (qPCR), and ethidium-monoazide-qPCR. Median toilet flushing annual infection risks exceeded 10 -4 considering multiple toilet types, while median clinical severity infection risks did not exceed this value. Sprinkler and cooling tower risks varied depending on meteorological conditions and operational characteristics such as drift eliminator performance. However, the greatest differences between risk scenarios were due to 1) the dose response model used (infection or clinical severity infection) 2) population at risk considered (residential or occupational) and 3) differences in laboratory analytical method. Theoretical setback distances necessary to achieve a median annual infection risk level of 10 -4 are proposed for spray irrigation and cooling towers. In both cooling tower and sprinkler cases, Legionella infection risks were non-trivial at potentially large setback distances, and indicate other simultaneous management practices could be needed to manage risks. The sensitivity analysis indicated that the most influential factors for variability in risks were the concentration of Legionella and aerosol partitioning and/or efficiency across all models, highlighting the importance of strategies to manage Legionella occurrence in reclaimed water. Copyright © 2018 Elsevier Ltd. All rights reserved.

  5. Modeling nitrate-nitrogen removal process in first-flush reactor for stormwater treatment.

    PubMed

    Deng, Zhiqiang; Sun, Shaowei; Gang, Daniel Dianchen

    2012-08-01

    Stormwater runoff is one of the most common non-point sources of water pollution to rivers, lakes, estuaries, and coastal beaches. While most pollutants and nutrients, including nitrate-nitrogen, in stormwater are discharged into receiving waters during the first-flush period, no existing best management practices (BMPs) are specifically designed to capture and treat the first-flush portion of urban stormwater runoff. This paper presents a novel BMP device for highway and urban stormwater treatment with emphasis on numerical modeling of the new BMP, called first-flush reactor (FFR). A new model, called VART-DN model, for simulation of denitrification process in the designed first-flush reactor was developed using the variable residence time (VART) model. The VART-DN model is capable of simulating various processes and mechanisms responsible for denitrification in the FFR. Based on sensitivity analysis results of model parameters, the denitrification process is sensitive to the temperature correction factor (b), maximum nitrate-nitrogen decay rate (K (max)), actual varying residence time (T (v)), the constant decay rate of denitrifiying bacteria (v (dec)), temperature (T), biomass inhibition constant (K (b)), maximum growth rate of denitrifiying bacteria (v (max)), denitrifying bacteria concentration (X), longitudinal dispersion coefficient (K (s)), and half-saturation constant of dissolved carbon for biomass (K (Car-X)); a 10% increase in the model parameter values causes a change in model root mean square error (RMSE) of -28.02, -16.16, -12.35, 11.44, -9.68, 10.61, -16.30, -9.27, 6.58 and 3.89%, respectively. The VART-DN model was tested using the data from laboratory experiments conducted using highway stormwater and secondary wastewater. Model results for the denitrification process of highway stormwater showed a good agreement with observed data and the simulation error was less than 9.0%. The RMSE and the coefficient of determination for simulating denitrification process of wastewater were 0.5167 and 0.6912, respectively, demonstrating the efficacy of the VART-DN model.

  6. The Human Right to Water--Market Allocations and Subsistence in a World of Scarcity

    ERIC Educational Resources Information Center

    McAdam, Kevin C.

    2005-01-01

    More than one billion people do not have access to an adequate water supply. In Gambia and Haiti, people live on less than 4 liters of water per day. By contrast, most toilets in the West use several times that amount of water for a single flush. The global distribution of water is making it increasingly difficult for poor people to access it, and…

  7. Thermal disinfection of hotels, hospitals, and athletic venues hot water distribution systems contaminated by Legionella species.

    PubMed

    Mouchtouri, Varvara; Velonakis, Emmanuel; Hadjichristodoulou, Christos

    2007-11-01

    Legionella spp. (> or = 500 cfu liter(-1)) were detected in 92 of 497 water distribution systems (WDS) examined. Thermal disinfection was applied at 33 WDS. After the first and second application of the disinfection procedure, 15 (45.4%) and 3 (9%) positive for remedial actions WDS were found, respectively. Legionella pneumophila was more resistant to thermal disinfection than Legionella non-pneumophila spp. (relative risk [RR]=5.4, 95% confidence intervals [CI]=1-35). WDS of hotels with oil heater were more easily disinfected than those with electrical or solar heater (RR=0.4 95% CI=0.2-0.8). Thermal disinfection seems not to be efficient enough to eliminate legionellae, unless repeatedly applied and in combination with extended heat flushing, and faucets chlorine disinfection.

  8. The effects of simulated rainfall on immature population dynamics of Aedes albopictus and female oviposition

    NASA Astrophysics Data System (ADS)

    Dieng, Hamady; Rahman, G. M. Saifur; Abu Hassan, A.; Che Salmah, M. R.; Satho, Tomomitsu; Miake, Fumio; Boots, Michael; Sazaly, Abubakar

    2012-01-01

    Larvae of Aedes albopictus Skuse typically inhabit natural and artificial containers. Since these larval habitats are replenished by rainfall, Ae. albopictus may experience increased loss of immature stages in areas with high levels of rainfall. In this study, we investigated the effects of rainfall and container water level on population density, and oviposition activity of Ae. albopictus. In field and laboratory experiments, we found that rainfall resulted in the flushing of breeding habitats. Excess rain negatively impacted larval and pupal retention, especially in small habitats. When filled with water to overflowing, container habitats were significantly repellent to ovipositing females. Taken together, these data suggest that rainfall triggers population loss of Ae. albopictus and related species through a direct detrimental effect (flushing out) and an indirect effect (ovipositional repellency).

  9. Examination and characterization of distribution system biofilms.

    PubMed Central

    LeChevallier, M W; Babcock, T M; Lee, R G

    1987-01-01

    Investigations concerning the role of distribution system biofilms on water quality were conducted at a drinking water utility in New Jersey. The utility experienced long-term bacteriological problems in the distribution system, while treatment plant effluents were uniformly negative for coliform bacteria. Results of a monitoring program showed increased coliform levels as the water moved from the treatment plant through the distribution system. Increased coliform densities could not be accounted for by growth of the cells in the water column alone. Identification of coliform bacteria showed that species diversity increased as water flowed through the study area. All materials in the distribution system had high densities of heterotrophic plate count bacteria, while high levels of coliforms were detected only in iron tubercles. Coliform bacteria with the same biochemical profile were found both in distribution system biofilms and in the water column. Assimilable organic carbon determinations showed that carbon levels declined as water flowed through the study area. Maintenance of a 1.0-mg/liter free chlorine residual was insufficient to control coliform occurrences. Flushing and pigging the study area was not an effective control for coliform occurrences in that section. Because coliform bacteria growing in distribution system biofilms may mask the presence of indicator organisms resulting from a true breakdown of treatment barriers, the report recommends that efforts continue to find methods to control growth of coliform bacteria in pipeline biofilms. Images PMID:3435140

  10. 32. INTERIOR OF STORM PORCH ADDITION SHOWING FLUSH SIDEEXIT DOOR ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    32. INTERIOR OF STORM PORCH ADDITION SHOWING FLUSH SIDEEXIT DOOR AT PHOTO LEFT CENTER AND 1-LIGHT OVER 1LIGHT SASH WINDOW THROUGH WEST WALL AT PHOTO RIGHT. VIEW TO SOUTH. - Rush Creek Hydroelectric System, Clubhouse Cottage, Rush Creek, June Lake, Mono County, CA

  11. Managing sewer solids for the reduction of foul flush effects--Forfar WTP.

    PubMed

    Fraser, A G; Sakrabani, R; Ashley, R M; Johnstone, F M

    2002-01-01

    In times of high sewer flow, conditions can exist which enable previously deposited material to be re-entrained back into the body of the flow column. Pulses of this highly polluted flow have been recorded in many instances at the recently constructed wastewater treatment plant (WTP) in Forfar, Scotland. Investigations have been undertaken to characterise the incoming flows and to suggest remedial measures to manage the quality fluctuations. Initial visits to the works and incoming pipes indicated a high degree of sediment deposition in the two inlet pipes. Analyses were carried out and consequently, changes to the hydraulic regime were made. Measurements of sediment level, sediment quality, wall slime and bulk water quality were monitored in the period following the remedial works to observe any improvements. Dramatic alterations in each of the determinands measured were recorded. Analyses were then undertaken to determine long term sediment behaviour and to assess the future usefulness of existing upstream sediment traps. It was concluded that with proper maintenance of the traps, the new hydraulic regime is sufficient to prevent further significant build up of sediment deposits and reduce impacts on the WTP. Further investigations made by North of Scotland Water Authority highlighted trade inputs to the system which may also have contributed to the now managed foul flush problem.

  12. Application of a flush airdata sensing system to a wing leading edge (LE-FADS)

    NASA Technical Reports Server (NTRS)

    Whitmore, Stephen A.; Moes, Timothy R.; Czerniejewski, Mark W.; Nichols, Douglas A.

    1993-01-01

    This paper investigates the feasibility of locating a flush air-data sensing (FADS) system on a wing leading edge where the operation of the avionics or fire control radar system will not be hindered. The leading-edge FADS system (LE-FADS) was installed on an unswept symmetrical airfoil, and a series of low-speed wind-tunnel tests were conducted to evaluate the performance of the system. As a result of the tests it is concluded that the aerodynamic models formulated for use on aircraft nosetips are directly applicable to wing leading edges and that the calibration process is similar. Furthermore, the agreement between the air-data calculations for angle of attack and total pressure from the LE-FADS and known wind-tunnel values suggest that wing-based flush air-data systems can be calibrated to a high degree of accuracy. Static wind-tunnel tests for angles of attack from -50 to 50 deg and dynamic pressures from 3.6 to 11.4 lb/sq ft were performed.

  13. Application of a Flush Airdata Sensing System to a Wing Leading Edge (LE-FADS)

    NASA Technical Reports Server (NTRS)

    Whitmore, Stephen A.; Moes, Timothy R.; Czerniejewski, Mark W.; Nichols, Douglas A.

    1993-01-01

    The feasibility of locating a flush airdata sensing (FADS) system on a wing leading edge where the operation of the avionics or fire control radar system will not be hindered is investigated. The leading-edge FADS system (LE-FADS) was installed on an unswept symmetrical airfoil and a series of low-speed wind-tunnel tests were conducted to evaluate the performance of the system. As a result of the tests it is concluded that the aerodynamic models formulated for use on aircraft nosetips are directly applicable to wing leading edges and that the calibration process is similar. Furthermore, the agreement between the airdata calculations for angle of attack and total pressure from the LE-FADS and known wind-tunnel values suggest that wing-based flush airdata systems can be calibrated to a high degree of accuracy. Static wind-tunnel tests for angles of attack from -50 deg to 50 deg and dynamic pressures from 3.6 to 11.4 lb/sq ft were performed.

  14. Sampling in schools and large institutional buildings: Implications for regulations, exposure and management of lead and copper.

    PubMed

    Doré, Evelyne; Deshommes, Elise; Andrews, Robert C; Nour, Shokoufeh; Prévost, Michèle

    2018-04-21

    Legacy lead and copper components are ubiquitous in plumbing of large buildings including schools that serve children most vulnerable to lead exposure. Lead and copper samples must be collected after varying stagnation times and interpreted in reference to different thresholds. A total of 130 outlets (fountains, bathroom and kitchen taps) were sampled for dissolved and particulate lead as well as copper. Sampling was conducted at 8 schools and 3 institutional (non-residential) buildings served by municipal water of varying corrosivity, with and without corrosion control (CC), and without a lead service line. Samples included first draw following overnight stagnation (>8h), partial (30 s) and fully (5 min) flushed, and first draw after 30 min of stagnation. Total lead concentrations in first draw samples after overnight stagnation varied widely from 0.07 to 19.9 μg Pb/L (median: 1.7 μg Pb/L) for large buildings served with non-corrosive water. Higher concentrations were observed in schools with corrosive water without CC (0.9-201 μg Pb/L, median: 14.3 μg Pb/L), while levels in schools with CC ranged from 0.2 to 45.1 μg Pb/L (median: 2.1 μg Pb/L). Partial flushing (30 s) and full flushing (5 min) reduced concentrations by 88% and 92% respectively for corrosive waters without CC. Lead concentrations were <10 μg Pb/L in all samples following 5 min of flushing. However, after only 30 min of stagnation, first draw concentrations increased back to >45% than values in 1st draw samples collected after overnight stagnation. Concentrations of particulate Pb varied widely (≥0.02-846 μg Pb/L) and was found to be the cause of very high total Pb concentrations in the 2% of samples exceeding 50 μg Pb/L. Pb levels across outlets within the same building varied widely (up to 1000X) especially in corrosive water (0.85-851 μg Pb/L after 30MS) confirming the need to sample at each outlet to identify high risk taps. Based on the much higher concentrations observed in first draw samples, even after a short stagnation, the first 250mL should be discarded unless no sources of lead are present. Results question the cost-benefit of daily or weekly flushing as a remediation strategy. As such, current regulatory requirements may fail to protect children as they may not identify problematic taps and effective mitigation measures. Copyright © 2018 Elsevier Ltd. All rights reserved.

  15. Integration of Energy/Sustainable Practices into Standard Army MILCON Designs: Energy and Sustainability Study

    DTIC Science & Technology

    2010-11-30

    approved climate zones) ► Dual flush toilets ► 1.5 GPM flow shower heads ► 0.5 GPM flow faucets ► Rainwater harvesting ► Permeable asphalt, permeable...for system with indirect evaporative pre-cooling Sustainability Measures ► Dual flush toilets ► 1.5 GPM flow shower heads, 0.5 GPM flow faucets...daylighting controls with 500 lux setpoint ► Dual flush toilets ►Waterless urinals ► 0.5 GPM flow faucets ► Rainwater harvesting ► Enhanced Commissioning

  16. Total parenteral nutrition

    MedlinePlus

    ... hands thoroughly with an antibacterial soap before TPN infusion. Turn on the water, wet your hands and ... pump according to the supplier's instructions. Before the infusion, unclamp the line and flush with saline. Twist ...

  17. Agricultural runoff pollution control by a grassed swales coupled with wetland detention ponds system: a case study in Taihu Basin, China.

    PubMed

    Zhao, Jinhui; Zhao, Yaqian; Zhao, Xiaoli; Jiang, Cheng

    2016-05-01

    The performance of a field grassed swales (GSs) coupled with wetland detention ponds (WDPs) system was monitored under four typical rainfall events to assess its effectiveness on agricultural runoff pollution control in Taihu Basin, China. The results indicated that suspended solids (SS) derived from the flush process has significant influence on pollution loads in agricultural runoff. Determination of first flush effect (FFE) indicated that total suspended solids (TSS) and total phosphorus (TP) exhibited moderate FFE, while chemical oxygen demand (COD) and total nitrogen (TN) showed weak FFE. Average removal efficiencies of 83.5 ± 4.5, 65.3 ± 6.8, 91.6 ± 3.8, and 81.3 ± 5.8 % for TSS, COD, TN, and TP were achieved, respectively. The GSs played an important role in removing TSS and TP and acted as a pre-treatment process to prevent clogging of the subsequent WDPs. Particle size distributions (PSDs) analysis indicated that coarse particles larger than 75 μm accounted for 80 % by weight of the total particles in the runoff. GSs can effectively reduce coarse particles (≥75 μm) in runoff, while its removal efficiency for fine particles (<75 μm) was low, even minus results being recorded, especially for particles smaller than 25 μm. The length of GSs is a key factor in its performance. The WDPs can remove particles of all sizes by sedimentation. In addition, WDPs can improve water quality due to their buffering and dilution capacity during rainfall as well as their water purification ability during dry periods. Overall, the ecological system of GSs coupled with WDPs is an effective system for agricultural runoff pollution control.

  18. Composting toilets as a sustainable alternative to urban sanitation--a review.

    PubMed

    Anand, Chirjiv K; Apul, Defne S

    2014-02-01

    In today's flush based urban sanitation systems, toilets are connected to both the centralized water and wastewater infrastructures. This approach is not a sustainable use of our water and energy resources. In addition, in the U.S., there is a shortfall in funding for maintenance and upgrade of the water and wastewater infrastructures. The goal of this paper was to review the current knowledge on composting toilets since this technology is decentralized, requires no water, creates a value product (fertilizer) and can possibly reduce the burden on the current infrastructure as a sustainable sanitation approach. We found a large variety of composting toilet designs and categorized the different types of toilets as being self contained or central; single or multi chamber; waterless or with water/foam flush, electric or non-electric, and no-mix or combined collection. Factors reported as affecting the composting process and their optimum values were identified as; aeration, moisture content (50-60%), temperature (40-65°C), carbon to nitrogen ratio (25-35), pH (5.5-8.0), and porosity (35-50%). Mass and energy balance models have been created for the composting process. However there is a literature gap in the use of this knowledge in design and operation of composting toilets. To evaluate the stability and safety of compost for use as fertilizer, various methods are available and the temperature-time criterion approach is the most common one used. There are many barriers to the use of composting toilets in urban settings including public acceptance, regulations, and lack of knowledge and experience in composting toilet design and operation and program operation. Copyright © 2013 Elsevier Ltd. All rights reserved.

  19. Low temperature barrier wellbores formed using water flushing

    DOEpatents

    McKinzie, II; John, Billy [Houston, TX; Keltner, Thomas Joseph [Spring, TX

    2009-03-10

    A method of forming an opening for a low temperature well is described. The method includes drilling an opening in a formation. Water is introduced into the opening to displace drilling fluid or indigenous gas in the formation adjacent to a portion of the opening. Water is produced from the opening. A low temperature fluid is applied to the opening.

  20. Analysis of boron dilution in a four-loop PWR

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sun, J.G.; Sha, W.T.

    1995-12-31

    Thermal mixing and boron dilution in a pressurized water reactor were analyzed with COMMIX codes. The reactor system was the four loop Zion reactor. Two boron dilution scenarios were analyzed. In the first scenario, the plant is in cold shutdown and the reactor coolant system has just been filled after maintenance on the steam generators. To flush the air out of the steam generator tubes, a reactor coolant pump (RCP) is started, with the water in the pump suction line devoid of boron and at the same temperature as the coolant in the system. In the second scenario, the plantmore » is at hot standby and the reactor coolant system has been heated up to operating temperature after a long outage. It is assumed that an RCP is started, with the pump suction line filled with cold unborated water, forcing a slug of diluted coolant down the downcomer and subsequently through the reactor core. The subsequent transient thermal mixing and boron dilution that would occur in the reactor system is simulated for these two scenarios. The reactivity insertion rate and the total reactivity are evaluated.« less

  1. Drinking of tap water is smart, but how do it better? - A tap water quality research

    NASA Astrophysics Data System (ADS)

    Mika, Anna; Sekuła, Klaudia; Dendys, Marta; Ptaszek, Weronika; Postawa, Adam

    2018-02-01

    Drinking tap water has recently become popular. It is a way to fight with the tons of garbage (disposable, plastic bottles). However, many people are afraid of water quality. The research was performed in December 2015 in Krakow, during one week. 56 samples were collected. The samples were taken in different times of the day and in the two types of building (old one with installation from the 80s and new one with installation built in past few years). Samples were taken by two qualified operators. The first sample was collected at the morning at 6 a.m., before anyone uses the tap. The second one after the tap was flushed and then the third one after 30 minutes stagnation. At the evening was taken one sample (after using the tap all day).The aim of the research was to check the quality of drinking water in the end-user. The results show that quality of tap water in Krakow is good, also in the end-user, but the concentration of chemical elements are changing during the flushing and using of the tap.

  2. Probability mass first flush evaluation for combined sewer discharges.

    PubMed

    Park, Inhyeok; Kim, Hongmyeong; Chae, Soo-Kwon; Ha, Sungryong

    2010-01-01

    The Korea government has put in a lot of effort to construct sanitation facilities for controlling non-point source pollution. The first flush phenomenon is a prime example of such pollution. However, to date, several serious problems have arisen in the operation and treatment effectiveness of these facilities due to unsuitable design flow volumes and pollution loads. It is difficult to assess the optimal flow volume and pollution mass when considering both monetary and temporal limitations. The objective of this article was to characterize the discharge of storm runoff pollution from urban catchments in Korea and to estimate the probability of mass first flush (MFFn) using the storm water management model and probability density functions. As a result of the review of gauged storms for the representative using probability density function with rainfall volumes during the last two years, all the gauged storms were found to be valid representative precipitation. Both the observed MFFn and probability MFFn in BE-1 denoted similarly large magnitudes of first flush with roughly 40% of the total pollution mass contained in the first 20% of the runoff. In the case of BE-2, however, there were significant difference between the observed MFFn and probability MFFn.

  3. Application of landfill treatment approaches for stabilization of municipal solid waste.

    PubMed

    Bolyard, Stephanie C; Reinhart, Debra R

    2016-09-01

    This research sought to compare the effectiveness of three landfill enhanced treatment approaches aimed at removing releasable carbon and nitrogen after anaerobic landfilling including flushing with clean water (FB 1), leachate recirculation with ex-situ treatment (FB 2), and leachate recirculation with ex-situ treatment and in-situ aeration (FB 3). After extensive treatment of the waste in the FB scenarios, the overall solids and biodegradable fraction were reduced relative to the mature anaerobically treated waste. In terms of the overall degradation, aeration did not provide any advantage over flushing and anaerobic treatment. Flushing was the most effective approach at removing biodegradable components (i.e. cellulose and hemicellulose). Leachate quality improved for all FBs but through different mechanisms. A significant reduction in ammonia-nitrogen occurred in FB 1 and 3 due to flushing and aeration, respectively. The reduction of chemical oxygen demand (COD) in FB 1 was primarily due to flushing. Conversely, the reduction in COD in FBs 2 and 3 was due to oxidation and precipitation during Fenton's Reagent treatment. A mass balance on carbon and nitrogen revealed that a significant fraction still remained in the waste despite the additional treatment provided. Carbon was primarily converted biologically to CH4 and CO2 in the FBs or removed during treatment using Fenton's Reagent. The nitrogen removal occurred through leaching or biological conversion. These results show that under extensive treatment the waste and leachate characteristics did meet published stability values. The minimum stability values achieved were through flushing although FB 2 and 3 were able to improve leachate quality and solid waste characteristics but not to the same extent as FB 1. Copyright © 2016 Elsevier Ltd. All rights reserved.

  4. Removing adsorbed heavy metal ions from sand surfaces via applying interfacial properties of rhamnolipid.

    PubMed

    Haryanto, Bode; Chang, Chien-Hsiang

    2015-01-01

    In this study, the interfacial properties of biosurfactant rhamnolipid were investigated and were applied to remove adsorbed heavy metal ions from sand surfaces with flushing operations. The surface tension-lowering activity, micelle charge characteristic, and foaming ability of rhamnolipid were identified first. For rhamnolipid in water, the negatively charged characteristic of micelles or aggregates was confirmed and the foaming ability at concentrations higher than 40 mg/L was evaluated. By using the rhamnolipid solutions in a batch washing approach, the potential of applying the interfacial properties of rhamnolipid to remove adsorbed copper ions from sand surfaces was then demonstrated. In rhamnolipid solution flushing operations for sand-packed medium, higher efficiency was found for the removal of adsorbed copper ions with residual type than with inner-sphere interaction type, implying the important role of interaction type between the copper ion and the sand surface in the removal efficiency. In addition, the channeling effect of rhamnolipid solution flow in the sand-packed medium was clearly observed in the solution flushing operations and was responsible for the low removal efficiency with low contact areas between solution and sand. By using rhamnolipid solution with foam to flush the sand-packed medium, one could find that the channeling effect of the solution flow was reduced and became less pronounced with the increase in the rhamnolipid concentration, or with the enhanced foaming ability. With the reduced channeling effect in the flushing operations, the removal efficiency for adsorbed copper ions was significantly improved. The results suggested that the foam-enhanced rhamnolipid solution flushing operation was efficient in terms of surfactant usage and operation time.

  5. Environmental occurrence and shallow ground water detection of the antibiotic monensin from dairy farms

    USGS Publications Warehouse

    Watanabe, N.; Harter, T.H.; Bergamaschi, B.A.

    2008-01-01

    Pharmaceuticals used in animal feeding operations have been detected in various environmental settings. There is a growing concern about the impact on terrestrial and aquatic organisms and the development of antibiotic-resistant strains of microorganisms. Pharmaceutical use in milking cows is relatively limited compared with other livestock operations, except for the ionophore monensin, which is given to lactating cows as a feed. By weight, monensin can be the most significant antibiotic used in a dairy farm. This study investigates the potential of monensin to move from dairy operations into the surrounding ground water. Using two dairy farms in California as study sites, we twice collected samples along the environmental pathway - from flush lanes, lagoon waters, and shallow ground water beneath the dairies and beneath its associated manured fields. Monensin concentrations were determined using solid-phase extraction and liquid chromatography-tandem mass spectrometry with positive electrospray ionization. Monensin was detected in all of the flush lane and lagoon water samples. Theoretical maximum concentration estimated from the actual dosing rate and the theoretical excretion rate assuming no attenuation was one order of magnitude greater than observed concentrations, suggesting significant attenuation in the manure collection and storage system. Monensin was also detected, at levels ranging from 0.04 to 0.39 ??g L-1, in some of the ground water samples underneath the production area of the dairy but not from the adjacent manured fields. Concentrations in ground water immediately downgradient of the lagoons were one to two orders of magnitude lower than the concentrations detected in lagoons, suggesting attenuation in the subsurface. The data suggest the possibility of monensin transport into shallow (2-5 m) alluvial ground water from dairy management units, including manure storage lagoons and freestalls occupied by heifers, lactating cows, and dry cows. Copyright ?? 2008 by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America. All rights reserved.

  6. Predicting temporal changes in total iron concentrations in groundwaters flowing from abandoned deep mines: a first approximation

    NASA Astrophysics Data System (ADS)

    Younger, Paul L.

    2000-06-01

    Discharges of contaminated groundwater from abandoned deep mines are a major environmental problem in many parts of the world. While process-based models of pollutant generation have been successfully developed for certain surface mines and waste rock piles of relatively simple geometry and limited areal extent, such models are not readily applicable to large systems of laterally extensive, interconnected, abandoned deep mines. As a first approximation for such systems, hydrological and lithological factors, which can reasonably be expected to influence pollutant release, have been assessed by empirically assessing data from 81 abandoned deep coal mine discharges in the UK. These data demonstrate that after flooding of a deep mine is complete and groundwater begins to migrate from the mine voids into surface waters or adjoining aquifers, flushing of the mine voids by fresh recharge results in a gradual improvement in the quality of groundwater (principally manifested as decreasing Fe concentrations and stabilisation of pH around 7). Alternative representations of the flushing process have been examined. While elegant analytical solutions of the advection-dispersion equation can be made to mimic the changes in iron concentration, parameterisation is tendentious in practice. Scrutiny of the UK data suggest that to a first approximation, the duration of the main period of flushing can be predicted to endure around four times as long as the foregoing process of mine flooding. Short- and long-term iron concentrations (i.e. at the start of the main period of flushing and after its completion, respectively) can be estimated from the sulphur content of the worked strata. If strata composition data are unavailable, some indication of pollution potential can be obtained from considerations of the proximity of worked strata to marine beds (which typically have high pyrite contents). The long-term concentrations of iron in a particular discharge can also be approximated on the basis of the proximity of the discharge location to the outcrop of the most closely associated coal seam (MCACS) and, thus, to zones of possible ongoing pyrite oxidation. The practical application of these simple predictive techniques is facilitated by means of a flowchart.

  7. Turbidity dynamics during spring storm events in an urban headwater river system: the Upper Tame, West Midlands, UK.

    PubMed

    Lawler, D M; Petts, G E; Foster, I D L; Harper, S

    2006-05-01

    Turbidity is an important water quality variable, through its relation to light suppression, BOD impact, sediment-associated contaminant transport, and suspended sediment effects on organisms and habitats. Yet few published field investigations of wet-weather turbidity dynamics, through several individual and sequenced rainstorms in extremely urbanised headwater basins, have emerged. This paper aims to address this gap through a turbidity analysis of multiple storm events in spring 2001 in an urban headwater basin (57 km2) of the River Tame, central England, the most urbanised basin for its size in the UK ( approximately 42%). Data were collected at 15-min frequency at automated monitoring stations for rainfall, streamflow and six water quality variables (turbidity, EC, temperature, DO, pH, ammonia). Disturbance experiments also allowed estimates of bed sediment storage to be obtained. Six important and unusual features of the storm event turbidity response were apparent: (1) sluggish early turbidity response, followed by a turbidity 'rush'; (2) quasi-coincident flow and turbidity peaks; (3) anti-clockwise hysteresis in the discharge-turbidity relationship on all but one event, resulting from Falling-LImb Turbidity Extensions (FLITEs); (4) increases in peak turbidity levels through storm sequences; (5) initial micro-pulses (IMP) in turbidity; and (6) secondary turbidity peaks (STP) or 'turbidity shoulders' (TS). These features provided very little evidence of a true 'first-flush' effect: instead, substantial suspended solids transport continued right through the flow recessions, and little storm-event sediment exhaustion was evident. A new, dimensionless, hysteresis index, HI(mid), is developed to quantify the magnitude and direction of hysteresis in a simple, clear, direct and intuitive manner. This allowed the degree of departure from the classic 'first-flush', clockwise hysteresis models to be assessed. Of the 15 turbidity events considered, 10 coincided with ammonia spikes of up to 6.25 mg l(-1) at Water Orton (the downstream station): this suggests that spills from combined sewer overflows (CSO) or waste water treatment works (WwTWs) are significant in the throughput of turbid waters here. Substantial ammonia peaks related most strongly to total storm rainfall receipt, of four rainfall variables considered, and significant ammonia peaks were generated even from low-magnitude storms (rainfall totals <4 mm), indicating that spills are a frequent occurrence. Local bed sediment stores appear to be limited, suggesting that other distal sediment sources, such as road networks and old mineworkings are possibly more important. Biofilms may also play a part in delaying sediment release until late in the hydrograph, and in suppressing late spring turbidity levels. Existing first-flush models appear to be an oversimplification here. Such urban headwater basin responses can provide useful insights into the generation of contaminant waves, and offer vital early-warning systems for pollution events propagating downstream.

  8. Modeling tidal exchange and dispersion in Boston Harbor

    USGS Publications Warehouse

    Signell, Richard P.; Butman, Bradford

    1992-01-01

    Tidal dispersion and the horizontal exchange of water between Boston Harbor and the surrounding ocean are examined with a high-resolution (200 m) depth-averaged numerical model. The strongly varying bathymetry and coastline geometry of the harbor generate complex spatial patterns in the modeled tidal currents which are verified by shipboard acoustic Doppler surveys. Lagrangian exchange experiments demonstrate that tidal currents rapidly exchange and mix material near the inlets of the harbor due to asymmetry in the ebb/flood response. This tidal mixing zone extends roughly a tidal excursion from the inlets and plays an important role in the overall flushing of the harbor. Because the tides can only efficiently mix material in this limited region, however, harbor flushing must be considered a two step process: rapid exchange in the tidal mixing zone, followed by flushing of the tidal mixing zone by nontidal residual currents. Estimates of embayment flushing based on tidal calculations alone therefore can significantly overestimate the flushing time that would be expected under typical environmental conditions. Particle-release simulations from point sources also demonstrate that while the tides efficiently exchange material in the vicinity of the inlets, the exact nature of dispersion from point sources is extremely sensitive to the timing and location of the release, and the distribution of particles is streaky and patchlike. This suggests that high-resolution modeling of dispersion from point sources in these regions must be performed explicitly and cannot be parameterized as a plume with Gaussian-spreading in a larger scale flow field.

  9. 40 CFR 721.1150 - Substituted polyglycidyl ben-zena-mine.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... following information: WARNING: CONTACT WITH SKIN AND EYES IS HARMFUL —Severe skin and eye irritant.... They have also caused allergic reactions in humans. —Prevent all contact with skin, eyes, and clothing... water. FIRST AID: —In case of eye contact, immediately flush with plenty of water and get immediate...

  10. Silage storage runoff characterization: Annual nutrient loading rate and first flush analysis of bunder silos

    USDA-ARS?s Scientific Manuscript database

    Silage runoff produced during the preservation and storage of dairy forage in horizontal bunkers is a source of nutrient loss from the farmstead and a threat to surface water quality. This research evaluated the runoff characteristics from six dairy bunker facilities to determine runoff water qualit...

  11. Asynchronous Amazon forest canopy phenology indicates adaptation to both water and light availability

    NASA Astrophysics Data System (ADS)

    Jones, Matthew O.; Kimball, John S.; Nemani, Ramakrishna R.

    2014-12-01

    Amazon forests represent nearly half of all tropical vegetation biomass and, through photosynthesis and respiration, annually process more than twice the amount of estimated carbon (CO2) from fossil fuel emissions. Yet the seasonality of Amazon canopy cover, and the extent to which seasonal fluctuations in water availability and photosynthetically available radiation influence these processes, is still poorly understood. Implementing six remotely sensed data sets spanning nine years (2003-2011), with reported field and flux tower data, we show that southern equatorial Amazon forests exhibit a distinctive seasonal signal. Seasonal timing of water availability, canopy biomass growth and net leaf flush are asynchronous in regions with short dry seasons and become more synchronous across a west-to-east longitudinal moisture gradient of increasing dry season. Forest cover is responsive to seasonal disparities in both water and solar radiation availability, temporally adjusting net leaf flush to maximize use of these generally abundant resources, while reducing drought susceptibility. An accurate characterization of this asynchronous behavior allows for improved understanding of canopy phenology across contiguous tropical forests and their sensitivity to climate variability and drought.

  12. 77 FR 76039 - Formations of, Acquisitions by, and Mergers of Bank Holding Companies

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-12-26

    ... York, with and into Flushing Commercial Bank, North New Hyde Park, New York, which will become a New York State-chartered commercial bank and change its name to Flushing Bank. Comments on this proposal... FEDERAL RESERVE SYSTEM Formations of, Acquisitions by, and Mergers of Bank Holding Companies The...

  13. Effect of point-of-use, activated carbon filters on the bacteriological quality of rural groundwater supplies.

    PubMed Central

    Synder, J W; Mains, C N; Anderson, R E; Bissonnette, G K

    1995-01-01

    The water quality of 24 rural, domestic groundwater supplies treated with point-of-use, powdered activated carbon (PAC) filters was monitored to determine how such treatment might impact the bacteriological quality of private, residential drinking water supplies. Heterotrophic-plate-count (HPC) and total coliform analyses were performed on raw, PAC-treated, and overnight or stagnant (first-draw) PAC-treated water samples. Densities of HPC bacteria were elevated by 0.86 and 0.20 orders of magnitude for spring and well water systems, respectively, in PAC-treated effluents following overnight stagnation compared with levels in untreated treated effluents. Densities of HPC bacteria in PAC-treated effluents were significantly reduced (P < 0.01) below influent levels, however, after the point-of-use device was flushed for 2 min. While PAC significantly reduced the number of coliforms in product waters (P < 0.01), these indicator organisms were still detected in some effluents. Seasonal variations were evident in microbial counts from spring but not well water systems. It appears that aside from periods following stagnant-water use, such as overnight, PAC treatment does not compromise the bacteriological quality of drinking water obtained from underground sources. PMID:8534096

  14. Eco-sewerage System Design for Modern Office Buildings: based on Vacuum and Source-separation Technology

    NASA Astrophysics Data System (ADS)

    Xu, Kangning; Wang, Chengwen; Zheng, Min; Yuan, Xin

    2010-11-01

    This study aimed to construct an on-site eco-sewerage system for modern office buildings in urban area based on combined innovative technologies of vacuum and source-separation. Results showed that source-separated grey water had low concentrations of pollutants, which helped the reuse of grey water. However, the system had a low separation efficiency between the yellow water and the brown water, which was caused by the plug problem in the urine collection from the urine-diverting toilets. During the storage of yellow water for liquid fertilizer production, nearly all urea nitrogen transferred to ammonium nitrogen and about 2/3 phosphorus was lost because of the struvite precipitation. Total bacteria and coliforms increased first in the storage, but then decreased to low concentrations. The anaerobic/anoxic/aerobic MBR had high elimination rates of COD, ammonium nitrogen and total nitrogen of the brown water, which were 94.2%, 98.1% and 95.1%, respectively. However, the effluent still had high contents of colority, nitrate and phosphorus, which affected the application of the effluent for flushing water. Even though, the effluent might be used as dilution water for the yellow water fertilizer. Based on the results and the assumption of an ideal operation of the vacuum source-separation system, a future plan for on-site eco-sewerage system of modern office buildings was constructed. Its sustainability was validated by the analysis of the substances flow of water and nutrients.

  15. Quality of stormwater runoff from paved surfaces of two production sites.

    PubMed

    Gnecco, I; Berretta, C; Lanza, L G; La Barbera, P

    2006-01-01

    In order to investigate stormwater pollutant loads associated with different anthropic activities and the related pollutant build-up and wash-off processes, two pilot sites have been equipped in the Liguria Region (Italy) for monitoring first flush water quality in a gas station and an auto dismantler facility. TSS, COD, HCtot and heavy metals in dissolved form (Zn, Pb, Cu, Ni, Cd, Cr) have been analyzed during the monitoring campaign (started in February 2004). Stormwater flow and quality data collected in both production sites confirm that EMC values are significantly higher than those observed in an urban site. In the auto dismantler site, the EMC values for TSS, COD and HC largely exceed the standard values (EC 91/271). Contrary to urban surface runoff, scarce correlation between TSS and COD concentrations is observed in runoff from both production sites. The occurrence and nature of the pollutant load connected to first flush flows is discussed by inspection of the M(V)-curves that are provided for all monitored water quality parameters. Significant first flush phenomenon is evidenced for TSS and HC, while such clear behavior doesn't emerge for heavy metals. Hydrologic and climatic characteristics (ADWP, rainfall intensity/depth) appear to scarcely affect the build-up and wash-off processes.

  16. Cyclodextrin-enhanced solubilization of organic contaminants with implications for aquifer remediation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McCray, J.E.; Boving, T.B.; Brusseau, M.L.

    2000-12-31

    Reagents that enhance the aqueous solubility of nonaqueous phase organic liquid (NAPL) contaminants are under investigation for use in enhanced subsurface remediation technologies. Cyclodextrin, a glucose-based molecule, is such a reagent. In this paper, laboratory experiments and numerical model simulations are used to evaluate and understand the potential remediation performance of cyclodextrin. Physical properties of cyclodextrin solutions such as density, viscosity, and NAPL-aqueous interfacial tension are measured. Their analysis indicates that no serious obstacles exist related to fluid properties that would prevent the use of cyclodextrin solutions for subsurface NAPL remediation. Cyclodextrin-enhanced solubilization for a large suite of typical groundmore » water contaminants is measured in the laboratory, and the results are related to the physiochemical properties of the organic compounds. The most-hydrophobic contaminants experience a larger relative solubility enhancement than the less-hydrophobic contaminants but have lower aqueous-phase apparent solubilities. Numerical model simulations of enhanced-solubilization flushing of NAPL-contaminated soil demonstrate that the more-hydrophilic compounds exhibit the greatest mass-removal relates due to their greater apparent solubilities, and thus are initially more effectively removed from soil by enhanced-solubilization-flushing reagents. However, the relatively more hydrophobic contaminants exhibit a greater improvement in contaminant mass-removal (compared with water flushing) than that exhibited for the relatively hydrophilic contaminants.« less

  17. Sterile Reverse Osmosis Water Combined with Friction Are Optimal for Channel and Lever Cavity Sample Collection of Flexible Duodenoscopes.

    PubMed

    Alfa, Michelle J; Singh, Harminder; Nugent, Zoann; Duerksen, Donald; Schultz, Gale; Reidy, Carol; DeGagne, Patricia; Olson, Nancy

    2017-01-01

    Simulated-use buildup biofilm (BBF) model was used to assess various extraction fluids and friction methods to determine the optimal sample collection method for polytetrafluorethylene channels. In addition, simulated-use testing was performed for the channel and lever cavity of duodenoscopes. BBF was formed in polytetrafluorethylene channels using Enterococcus faecalis, Escherichia coli , and Pseudomonas aeruginosa . Sterile reverse osmosis (RO) water, and phosphate-buffered saline with and without Tween80 as well as two neutralizing broths (Letheen and Dey-Engley) were each assessed with and without friction. Neutralizer was added immediately after sample collection and samples concentrated using centrifugation. Simulated-use testing was done using TJF-Q180V and JF-140F Olympus duodenoscopes. Despite variability in the bacterial CFU in the BBF model, none of the extraction fluids tested were significantly better than RO. Borescope examination showed far less residual material when friction was part of the extraction protocol. The RO for flush-brush-flush (FBF) extraction provided significantly better recovery of E. coli ( p  = 0.02) from duodenoscope lever cavities compared to the CDC flush method. We recommend RO with friction for FBF extraction of the channel and lever cavity of duodenoscopes. Neutralizer and sample concentration optimize recovery of viable bacteria on culture.

  18. Feasibility study of rainwater harvesting for domestic use (Case study: West Jakarta rainfall data)

    NASA Astrophysics Data System (ADS)

    Kartolo, Jason; Kusumawati, Elly

    2017-11-01

    Rainwater Harvesting system is one of considerable choice to reduce flood in Jakarta, moreover it helps to reduce main tap water consumption. In this study, rainwater is used for flushing toilet and watering garden for domestic use. Rainwater harvesting system is examined for 60 m2 and 90 m2 housing area, using rainfall data from Cengkareng station in West Jakarta. Two type of rainwater harvesting reservoir is designed, those are ground reservoir and underground reservoir. From the analysis, it finds that 60 m2 house feasible for 1 m3 ground reservoir and 9 m3 underground reservoir. Meanwhile for 90 m2 house 2 m3 tanks ground reservoir and 14 m3 tank underground reservoir is feasible. Underground reservoir retain more water volume so it provide higher rate of water supply. The cost of underground reservoir is lower 60% - 70% than ground reservoir. Even though rainwater harvesting is technically feasible for housing, it is not economically feasible. The construction cost is higher than the benefit of reduced tap water consumption.

  19. Assessments of quaternary ammonium compounds (QAC) for in-water treatment of mussel fouling in vessel internals and sea chests using an experimental seawater pipework system.

    PubMed

    Piola, Richard; Grandison, Clare

    2017-01-01

    The primary in-water emergency treatment method for mussel fouling of internal seawater systems of Royal Australian Navy vessels is to flush with a 1% detergent solution containing quaternary ammonium compounds (QAC). Parameters for application of this treatment are based on previous research; however, much of the research has been conducted at small-scales under controlled laboratory conditions. This study examined the efficacy of QAC solutions for treating mussel biofouling under realistic field conditions using experimental seawater piping systems. The efficacy of QAC solutions was highly dependent on the size of mussels present. Chemical treatments comprising 1, 2 and 5% v v -1 QAC solution were effective at killing large (50-92 mm) mussels in the pipework and sea chest of the system following 24 h exposure. In contrast, small mussels (10-30 mm) appeared resilient to the majority of treatment regimes. Differences in water temperature, DO and pH during dosing had no discernible impact on treatment efficacy.

  20. Use patterns, excretion masses and contamination profiles of antibiotics in a typical swine farm, south China.

    PubMed

    Zhou, Li-Jun; Ying, Guang-Guo; Zhang, Rui-Quan; Liu, Shan; Lai, Hua-Jie; Chen, Zhi-Feng; Yang, Bin; Zhao, Jian-Liang

    2013-04-01

    The objective of this study was to screen the occurrence of 50 antibiotics in a typical swine farm in southern China, which includes animal feeds, waste collection and treatment systems (lagoons and anaerobic digesters), and receiving environments (vegetable fields, streams, and private wells). Nine antibiotics were found in the feeds for different stages of the development of pigs in the swine farm, at concentrations ranging from 2.37 ± 0.16 ng g(-1) (sulfamethazine) to 61 500 ± 11 900 ng g(-1) (bacitracin). 11, 17 and 15 target compounds were detected in feces, flush water, and suspended particles in the swine farm, respectively. Based on the survey of feeds and animal waste from the farm, chlortetracycline, tetracycline, bacitracin and florfenicol in the feces, flush water and suspended particles mainly originated from the feeds, while most sulfonamides, including doxycycline, oxytetracycline, fluoroquinolones, macrolides and trimethoprim, were mainly from injection and other oral routes. The daily excretion masses of antibiotics per pig calculated based on animal waste had the following order: sows (48.3 mg per day per pig), piglets (18.9 mg per day per pig), growing pigs (7.01 mg per day per pig) and finishing pigs (1.47 mg per day per pig), indicating that the usage of antibiotics (type and dosage) and excretion masses are related to the growth stage of pigs. Chlortetracycline and bacitracin are the main contributors to the total excretion mass of antibiotics from pigs at different stages of development in the farm. The waste treatment system (lagoons and anaerobic digesters) was found to be ineffective in the elimination of antibiotics. The detection of some antibiotics in the surrounding environments of the farm (the well water, stream water and vegetable field soil) was a reflection of pollution from the swine farm.

  1. Assessment of water consumptions in small mediterranean islands' primary schools by means of a long-term online monitoring

    NASA Astrophysics Data System (ADS)

    Ferraris, Marco; De Gisi, Sabino; Farina, Roberto

    2017-10-01

    A key challenge of our society is improving schools through the sustainable use of resources especially in countries at risk of desertification. The estimation of water consumption is the starting point for the correct dimensioning of water recovery systems. To date, unlike the energy sector, there is a lack of scientific information regarding water consumption in school buildings. Available data refer roughly to indirect estimates by means of utility bills and therefore no information on the role of water leakage in the internal network of the school is provided. In this context, the aim of the work was to define and implement an on-line monitoring system for the assessment of water consumptions in a small Mediterranean island primary school to achieve the following sub-goals: (1) definition of water consumption profile considering teaching activities and secretarial work; (2) direct assessment of water consumptions and leakages and, (3) quantification of the behaviour parameters. The installed monitoring system consisted of 33 water metres (3.24 persons per water metre) equipped with sensors set on 1-L impulse signal and connected to a data logging system. Results showed consumptions in the range 13.6-14.2 L/student/day and leakage equal to 54.8 % of the total water consumptions. Considering the behavioural parameters, the consumptions related to toilet flushing, personal, and building cleaning were, respectively, 54, 43 and 3 % of the total water ones. Finally, the obtained results could be used for dimensioning the most suitable water recovery strategies at school level such as grey water or rainwater recovery systems.

  2. Lead as a legendary pollutant with emerging concern: Survey of lead in tap water in an old campus building using four sampling methods.

    PubMed

    Ng, Ding-Quan; Liu, Shu-Wei; Lin, Yi-Pin

    2018-09-15

    In this study, a sampling campaign with a total of nine sampling events investigating lead in drinking water was conducted at 7 sampling locations in an old building with lead pipes in service in part of the building on the National Taiwan University campus. This study aims to assess the effectiveness of four different sampling methods, namely first draw sampling, sequential sampling, random daytime sampling and flush sampling, in lead contamination detection. In 3 out of the 7 sampling locations without lead pipe, lead could not be detected (<1.1 μg/L) in most samples regardless of the sampling methods. On the other hand, in the 4 sampling locations where lead pipes still existed, total lead concentrations >10 μg/L were consistently observed in 3 locations using any of the four sampling methods while the remaining location was identified to be contaminated using sequential sampling. High lead levels were consistently measured by the four sampling methods in the 3 locations in which particulate lead was either predominant or comparable to soluble lead. Compared to first draw and random daytime samplings, although flush sampling had a high tendency to reduce total lead in samples in lead-contaminated sites, the extent of lead reduction was location-dependent and not dependent on flush durations between 5 and 10 min. Overall, first draw sampling and random daytime sampling were reliable and effective in determining lead contamination in this study. Flush sampling could reveal the contamination if the extent is severe but tends to underestimate lead exposure risk. Copyright © 2018 Elsevier B.V. All rights reserved.

  3. After an exposure to sharps or body fluids

    MedlinePlus

    ... the area with soap and water. For a splash exposure to the nose, mouth, or skin, flush ... designing, implementing, and evaluating a sharps injury prevention program. www.cdc.gov/sharpssafety/pdf/sharpsworkbook_2008.pdf . ...

  4. Reactive solute transport in an asymmetric aquifer-aquitard system with scale-dependent dispersion

    NASA Astrophysics Data System (ADS)

    Zhou, R.; Zhan, H.

    2017-12-01

    Abstract: The understanding of reactive solute transport in an aquifer-aquitard system is important to study transport behavior in the more complex porous media. When transport properties are asymmetric in the upper and lower aquitards, reactive solute transport in such an aquifer-aquitard system becomes a coupled three domain problem that is more complex than the symmetric case in which the upper and lower aquitards have identical transport properties. Meanwhile, the dispersivity of transport in the aquifer is considered as a linear or exponential function of travel distance due to the heterogeneity of aquifer. This study proposed new transport models to describe reactive solute transport in such an asymmetric aquifer-aquitard system with scale-dependent dispersion. Mathematical models were developed for such problems under the first-type and third-type boundary conditions to analyze the spatial-temporal concentration and mass distribution in the aquifer and aquitards with the help of Laplace transform technique and the de Hoog numerical Laplace inversion method. Breakthrough curves (BTCs) and residence time distribution curves (RTDs) obtained from the models with scale-dependent dispersion, constant dispersion and constant effective dispersivity were compared to reflect the lumped scale-dispersion effect in the aquifer-aquitard system. The newly acquired solutions were then tested extensively against previous analytical and numerical solutions and were proven to be robust and accurate. Furthermore, to study the back diffusion of contaminant mass in aquitards, a zero-contaminant mass concentration boundary condition was imposed on the inlet boundary of the system after a certain time, which is also called the process of water flushing. The diffusion loss alone the aquifer/aquitard interfaces and mass stored ratio change in each of three domains (upper aquitard, aquifer, and lower aquitard) after water flushing provided an insightful and comprehensive analysis of transport behavior with asymmetric distribution of transport properties.

  5. Faecal contamination of a municipal drinking water distribution system in association with Campylobacter jejuni infections.

    PubMed

    Pitkänen, Tarja; Miettinen, Ilkka T; Nakari, Ulla-Maija; Takkinen, Johanna; Nieminen, Kalle; Siitonen, Anja; Kuusi, Markku; Holopainen, Arja; Hänninen, Marja-Liisa

    2008-09-01

    After heavy rains Campylobacter jejuni together with high counts of Escherichia coli, other coliforms and intestinal enterococci were detected from drinking water of a municipal distribution system in eastern Finland in August 2004. Three patients with a positive C. jejuni finding, who had drunk the contaminated water, were identified and interviewed. The pulsed-field gel electrophoresis (PFGE) genotypes from the patient samples were identical to some of the genotypes isolated from the water of the suspected contamination source. In addition, repetitive DNA element analysis (rep-PCR) revealed identical patterns of E. coli and other coliform isolates along the distribution line. Further on-site technical investigations revealed that one of the two rainwater gutters on the roof of the water storage tower had been in an incorrect position and rainwater had flushed a large amount of faecal material from wild birds into the drinking water. The findings required close co-operation between civil authorities, and application of cultivation and genotyping techniques strongly suggested that the municipal drinking water was the source of the infections. The faecal contamination associated with failures in cleaning and technical management stress the importance of instructions for waterworks personnel to perform maintenance work properly.

  6. Seasonal Variation in Drinking and Domestic Water Sources and Quality in Port Harcourt, Nigeria

    PubMed Central

    Kumpel, Emily; Cock-Esteb, Alicea; Duret, Michel; de Waal, Dominick; Khush, Ranjiv

    2017-01-01

    We compared dry and rainy season water sources and their quality in the urban region of Port Harcourt, Nigeria. Representative sampling indicated that municipal water supplies represent < 1% of the water sources. Residents rely on privately constructed and maintained boreholes that are supplemented by commercially packaged bottled and sachet drinking water. Contamination by thermotolerant coliforms increased from 21% of drinking water sources in the dry season to 42% of drinking water sources in the rainy season (N = 356 and N = 397). The most significant increase was in sachet water, which showed the lowest frequencies of contamination in the dry season compared with other sources (15%, N = 186) but the highest frequencies during the rainy season (59%, N = 76). Only half as many respondents reported drinking sachet water in the rainy season as in the dry season. Respondents primarily used flush or pour-flush toilets connected to septic tanks (85%, N = 399). The remainder relied on pit latrines and hanging (pier) latrines that drained into surface waters. We found significant associations between fecal contamination in boreholes and the nearby presence of hanging latrines. Sanitary surveys of boreholes showed that more than half were well-constructed, and we did not identify associations between structural or site deficiencies and microbial water quality. The deterioration of drinking water quality during the rainy season is a serious public health risk for both untreated groundwater and commercially packaged water, highlighting a need to address gaps in monitoring and quality control. PMID:27821689

  7. Aspects of municipal wastewater reclamation and reuse for future water resource shortages in Taiwan.

    PubMed

    Chiou, R J; Chang, T C; Ouyang, C F

    2007-01-01

    The Water Resources Agency (WRA), Ministry of Economic Affairs (MOEA) has predicted that the annual water demand in Taiwan will reach approximately 20 billion m3 by 2021. However, the present water supply is only 18 billion m3 per year. This means that an additional 2 billion m3 have to be developed in the next 17 years. The reuse of treated wastewater effluent from municipal wastewater treatment plants could be one target for the development of new water resources. The responsible government departments already have plans to construct public sewerage systems in order to improve the quality of life of the populace and protect the environment. The treated wastewater effluent from such municipal wastewater treatment plants could be a very stable and readily available secondary type of water resource, different from the traditional types of water resources. The major areas where reclaimed municipal wastewater can be used to replace traditional fresh water resources include agricultural and landscape irrigation, street cleaning, toilet flushing, secondary industrial reuse and environmental uses. However, necessary wastewater reclamation and reuse systems have not yet been established. The requirements for their establishment include water reuse guidelines and criteria, the elimination of health risks ensuring safe use, the determination of the wastewater treatment level appropriate for the reuse category, as well as the development and application of management systems reuse. An integrated system for water reuse would be of great benefit to us all by providing more efficient ways to utilise the water resources.

  8. 7. INTERIOR OF LIVING ROOM SHOWING FLUSH FRONT DOOR AT ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    7. INTERIOR OF LIVING ROOM SHOWING FLUSH FRONT DOOR AT PHOTO CENTER, MODERN SIDING WINDOW ON EAST WALL (FORMER PORCH) AT PHOTO CENTER RIGHT, AND ORIGINAL PAIRED 6-LIGHT OVER 1-LIGHT WINDOWS ON NORTH WALL (PHOTO LEFT). VIEW TO NORTHEAST. - Bishop Creek Hydroelectric System, Control Station, Worker Cottage, Bishop Creek, Bishop, Inyo County, CA

  9. Effect of different water management strategies on water and contaminant fluxes in Doncaster, United Kingdom.

    PubMed

    Rueedi, J; Cronin, A A; Moon, B; Wolf, L; Hoetzl, H

    2005-01-01

    In Europe, large volumes of public water supply come from urban aquifers and so efficient urban water management and decision tools are essential to maintain quality of life both in terms of health, personal freedom and environment. In the United Kingdom, this issue gained increased importance with the last year's low volumes of groundwater replenishment that resulted in increased water shortages all over the country. An urban water volume and quality model (UVQ) was applied to a suburb of Doncaster (United Kingdom) to assess the current water supply system and to compare it with new potential scenarios of water management. The initial results show considerable changes in both water and solute fluxes for some scenarios and rather limited changes for others. Changing impermeable roads and paved areas to permeable areas, for example, would lead to higher infiltration rates that may be welcome from a water resources viewpoint but less so from a water quality point of view due to high concentrations of heavy metals. The biggest impact on water quality and quantity leaving the system through sewer, storm water and infiltration system was clearly obtained by re-using grey water from kitchen, bathroom and laundry for irrigation and toilet flush. The testing of this strategy led to lower volumes and higher concentrations of sewerage, a considerable decrease in water consumption and an increase in groundwater recharge. The scenarios were tested neither in terms of costs nor social acceptance for either water supplier or user.

  10. A sustainable approach towards rural development: dry toilets in Nepal.

    PubMed

    Regmi, M R

    2005-01-01

    Existing inadequate sewerage systems and direct disposal of household waste into water courses has tremendously increased water pollution. Dry toilets are feasible in rural and peri-urban areas to reduce the consumption of costlier water that is required for flushing. As conventional treatment technologies require high investment, and operation and maintenance costs, dry toilets are the only suitable option left for sanitation in the 21st century when working with limited financial resources. To reduce environmental degradation and overcome this problem, the dry toilet is only the realistic option in Nepal. Two reactors, one exposed to sunrays and the other without sunrays, were constructed. In the model with sunrays, it was found that in 48 days of observation faecal coliform presence depleted to 610 cells per gm from the initial value of 7 x 10(10) and volatile organic matter came down from 98.09% to 70.18%. Similarly, in the other model, the destruction of faecal coliform in 65 days was found to be 920 cells/gm while the destruction of organic matter took 75 days. Also, observing from 313 people in a cluster on the pilot project, the annually recovered value of N, P and K was found to be 1565 kg, 125 kg, 344 kg, respectively. This paper deals with the different types of dry ecological toilet, their performance and feasibility study in Nepal, with the full involvement of local people, based on complete laboratory analysis and regular monitoring. Using dry toilets will save 14 LPCD, which is equivalent to 14 MLD and the resulting demand will become only 80 MLD for the urban area of Kathmandu. The result advocates the implementation of ecological dry toilets to save valuable water wasted in flushing, as well as saving the resources needed to treat the waste.

  11. Characterizing dry deposition of mercury in urban runoff

    USGS Publications Warehouse

    Fulkerson, M.; Nnadi, F.N.; Chasar, L.S.

    2007-01-01

    Stormwater runoff from urban surfaces often contains elevated levels of toxic metals. When discharged directly into water bodies, these pollutants degrade water quality and impact aquatic life and human health. In this study, the composition of impervious surface runoff and associated rainfall was investigated for several storm events at an urban site in Orlando, Florida. Total mercury in runoff consisted of 58% particulate and 42% filtered forms. Concentration comparisons at the start and end of runoff events indicate that about 85% of particulate total mercury and 93% of particulate methylmercury were removed from the surface before runoff ended. Filtered mercury concentrations showed less than 50% reduction of both total and methylmercury from first flush to final flush. Direct comparison between rainfall and runoff at this urban site indicates dry deposition accounted for 22% of total inorganic mercury in runoff. ?? 2007 Springer Science+Business Media B.V.

  12. [Analysis of first flush effect of typical underlying surface runoff in Beijing urban city].

    PubMed

    Ren, Yu-Fen; Wang, Xiao-Ke; Ouyang, Zhi-Yun; Hou, Pei-Qiang

    2013-01-01

    Rapid increase of the urban impervious underlying surfaces causes a great increase of urban runoff and the accumulation of pollutants on the roof and road surfaces brings many pollutants into the drainage system with the runoff, and it thus becomes a great threat to the urban water environment. To know the runoff pollution process and to build scientific basis for pollutant control, runoff processes from the roof and road surfaces were monitored and analyzed from 2004 to 2006, and the runoff EMC (Event Mean Concentration) was calculated. It was found that two types of runoff were seriously polluted by COD and TN. The COD and TN of roof runoff exceeded the fifth level of the surface water environmental quality standard (GB 3838-2002) by 3.64 and 4.80 times, respectively, and the COD and TN of road runoff exceeded by 3.73 and 1.07 times, respectively. M (V) curve was used to determine the relation between runoff volume and runoff pollution load. Various degrees of the first flush phenomenon were found for TSS, COD, TN and TP in roof runoff. But this phenomenon occurred only for TSS and TP of the road runoff, and on the whole it was not obvious. Properties of the underlying surfaces, rainfall intensity, and pollutant accumulation are all important factors affecting the roof and road runoff pollutant emission characteristics.

  13. Experimental comparison of point-of-use filters for drinking water ultrafiltration.

    PubMed

    Totaro, M; Valentini, P; Casini, B; Miccoli, M; Costa, A L; Baggiani, A

    2017-06-01

    Waterborne pathogens such as Pseudomonas spp. and Legionella spp. may persist in hospital water networks despite chemical disinfection. Point-of-use filtration represents a physical control measure that can be applied in high-risk areas to contain the exposure to such pathogens. New technologies have enabled an extension of filters' lifetimes and have made available faucet hollow-fibre filters for water ultrafiltration. To compare point-of-use filters applied to cold water within their period of validity. Faucet hollow-fibre filters (filter A), shower hollow-fibre filters (filter B) and faucet membrane filters (filter C) were contaminated in two different sets of tests with standard bacterial strains (Pseudomonas aeruginosa DSM 939 and Brevundimonas diminuta ATCC 19146) and installed at points-of-use. Every day, from each faucet, 100 L of water was flushed. Before and after flushing, 250 mL of water was collected and analysed for microbiology. There was a high capacity of microbial retention from filter C; filter B released only low Brevundimonas spp. counts; filter A showed poor retention of both micro-organisms. Hollow-fibre filters did not show good micro-organism retention. All point-of-use filters require an appropriate maintenance of structural parameters to ensure their efficiency. Copyright © 2016 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  14. Oxygen intrusion into anoxic fjords leads to increased methylmercury availability

    NASA Astrophysics Data System (ADS)

    Veiteberg Braaten, Hans Fredrik; Pakhomova, Svetlana; Yakushev, Evgeniy

    2013-04-01

    Mercury (Hg) appears in the oxic surface waters of the oceans at low levels (sub ng/L). Because inorganic Hg can be methylated into the toxic and bioaccumulative specie methylmercury (MeHg) levels can be high at the top of the marine food chain. Even though marine sea food is considered the main risk driver for MeHg exposure to people most research up to date has focused on Hg methylation processes in freshwater systems. This study identifies the mechanisms driving formation of MeHg during oxygen depletion in fjords, and shows how MeHg is made available in the surface water during oxygen intrusion. Studies of the biogeochemical structure in the water column of the Norwegian fjord Hunnbunn were performed in 2009, 2011 and 2012. In autumn of 2011 mixing flushing events were observed and lead to both positive and negative effects on the ecosystem state in the fjord. The oxygenated water intrusions lead to a decrease of the deep layer concentrations of hydrogen sulfide (H2S), ammonia and phosphate. On the other hand the intrusion also raised the H2S boundary from 8 m to a shallower depth of just 4 m. Following the intrusion was also observed an increase at shallower depths of nutrients combined with a decrease of pH. Before flushing events were observed concentrations of total Hg (TotHg) increased from 1.3 - 1.7 ng/L in the surface layer of the fjord to concentrations ranging from 5.2 ng/L to 6.4 ng/L in the anoxic zone. MeHg increased regularly from 0.04 ng/L in the surface water to a maximum concentration of 5.2 ng/L in the deeper layers. This corresponds to an amount of TotHg present as MeHg ranging from 2.1 % to 99 %. The higher concentrations of MeHg in the deeper layer corresponds to an area where no oxygen is present and concentrations of H2S exceeds 500 µM, suggesting a production of MeHg in the anoxic area as a result of sulphate reducing bacteria activity. After flushing the concentrations of TotHg showed a similar pattern ranging from 0.6 ng/L in the surface layer to 6.5 ng/L at maximum depth (10 m). However, the pattern of MeHg concentrations in the water column changed with relatively high concentrations present already at 4.5 m depth (2.2 ng/L). The environmental consequence of this oxygen intrusion is the appearance in shallower water of toxic MeHg formed in the anoxic layer. As a result of this, MeHg can possibly undergo transport from the anoxic fjord to the surrounding areas.

  15. Regenerative (Regen) ECLSS Operations Water Balance

    NASA Technical Reports Server (NTRS)

    Tobias, Barry

    2010-01-01

    In November 2008, the Water Regenerative System racks were launched aboard Space Shuttle flight, STS-126 (ULF2) and installed and activated on the International Space Station (ISS). These racks, consisting of the Water Processor Assembly (WPA) and Urine Processor Assembly (UPA), completed the installation of the Regenerative (Regen) ECLSS systems which includes the Oxygen Generator Assembly (OGA) that was launched 2 years prior. With the onset of active water management on the US segment of the ISS, a new operational concept was required, that of "water balance." Even more recently, in 2010 the Sabatier system came online which converts H2 and CO2 into water and methane. The Regen ECLSS systems accept condensation from the atmosphere, urine from crew, and processes that fluid via various means into potable water which is used for crew drinking, building up skip-cycle water inventory, and water for electrolysis to produce oxygen. Specification rates of crew urine output, condensate output, O2 requirements, toilet flush water and drinking needs are well documented and used as a general plan when Regen ECLSS came online. Spec rates are useful in long term planning, however, daily or weekly rates are dependent on a number of variables. The constantly changing rates created a new challenge for the ECLSS flight controllers, who are responsible for operating the ECLSS systems onboard ISS. This paper will review the various inputs to rate changes and inputs to planning events, including but not limited to; crew personnel makeup, Regen ECLSS system operability, vehicle traffic, water containment availability, and Carbon Dioxide Removal Assembly (CDRA) capability. Along with the inputs that change the various rates, the paper will review the different systems, their constraints and finally the operational means by which flight controllers manage this new challenge of "water balance."

  16. Decontamination of biological agents from drinking water infrastructure: a literature review and summary.

    PubMed

    Szabo, Jeff; Minamyer, Scott

    2014-11-01

    This report summarizes the current state of knowledge on the persistence of biological agents on drinking water infrastructure (such as pipes) along with information on decontamination should persistence occur. Decontamination options for drinking water infrastructure have been explored for some biological agents, but data gaps remain. Data on bacterial spore persistence on common water infrastructure materials such as iron and cement-mortar lined iron show that spores can be persistent for weeks after contamination. Decontamination data show that common disinfectants such as free chlorine have limited effectiveness. Decontamination results with germinant and alternate disinfectants such as chlorine dioxide are more promising. Persistence and decontamination data were collected on vegetative bacteria, such as coliforms, Legionella and Salmonella. Vegetative bacteria are less persistent than spores and more susceptible to disinfection, but the surfaces and water quality conditions in many studies were only marginally related to drinking water systems. However, results of real-world case studies on accidental contamination of water systems with E. coli and Salmonella contamination show that flushing and chlorination can help return a water system to service. Some viral persistence data were found, but decontamination data were lacking. Future research suggestions focus on expanding the available biological persistence data to other common infrastructure materials. Further exploration of non-traditional drinking water disinfectants is recommended for future studies. Published by Elsevier Ltd.

  17. Impacts of climate change on rainfall, seasonal flooding, and evapotranspiration in the Okavango Delta, Botswana

    NASA Astrophysics Data System (ADS)

    Konecky, B. L.; Noone, D.; Mosimanyana, E.; Gondwe, M.

    2016-12-01

    The Okavango Delta in northern Botswana is one of the world's richest biodiversity hotspots. A UNESCO World Heritage Site, the Delta is known for its unique annual flood pulse, whereby the wetland and its neighboring river systems are inundated with waters that travel nearly 1000 km before reaching this subtropical, semi-arid destination. The livelihoods of northern Botswana's ecosystems and human populations rely on these floods to supplement the short and variable rainy season, which in many years is too minimal to ameliorate regional drought. However, anthropogenic climate change is reducing the amount of water that reaches the delta by increasing evaporation from soils and rivers, and transpiration by vegetation, during its long transit to Botswana. Future changes in rainfall patterns, extreme events, and increased upstream water use could exacerbate this water stress. Unfortunately, it remains difficult to assess the impacts of climate change on the delta because few data exist to constrain its complex climatic and seasonal water cycling regimes. This study presents a novel characterization of the water cycle in and around the Okavango Delta based on a survey of free-flowing surface waters, stagnant pools, precipitation, and groundwater carried out during the 2016 rainy and early-flood season. We use stable isotope and water quality data to assess local moisture sources, transport, evaporation, wetland flushing, and land-atmosphere exchanges, all of which are subject to change under global warming. We find a strong evaporation gradient and a progressive flushing of stagnant swamp waters along the northeastern and northwestern channels of the Delta. The evaporation gradient is more limited in nearby rivers with more limited wetlands. We contrast results with a survey of the Delta performed in the 1970's in order to assess changes over the past 40 years. Since some of these changes may arise from rainfall supply, we also present new analysis of rainfall moisture sources and transport characteristics during 2016's unusually-late wet season, using both in situ and satellite data. Implications are discussed for the large-scale water cycling over the southern African continental interior. These data serve as a baseline for future monitoring under climate change.

  18. Premedication with N-acetylcysteine and simethicone improves mucosal visualization during gastroscopy: a randomized, controlled, endoscopist-blinded study.

    PubMed

    Neale, James R; James, Shirley; Callaghan, James; Patel, Praful

    2013-07-01

    Diagnostic gastroscopy provides a unique opportunity to diagnose early oesophagogastric neoplasia; however, intraluminal mucus and bile can obscure mucosal visualization. The aim of this study was to determine whether the use of a premedication solution containing the mucolytic agent N-acetylcysteine and the surfactant simethicone improves mucosal visualization within a UK diagnostic gastroscopy service. A total of 75 consecutive patients were recruited from a single (S.J.) endoscopist's diagnostic gastroscopy list. They were randomized into three treatment groups: (a) standard control=clear fluids only for 6 h, nil by mouth for 2 h; (b) water control=standard control+100 ml sterile water (given 20 min before gastroscopy); and (c) solution=standard control+100 ml investigated solution (20 min before gastroscopy). The endoscopist was blinded to patient preparation. Inadequate mucosal visualization was defined as fluid/mucus during gastroscopy that could not be suctioned and required flushing with water. The volume of flush, the site at which it was used and the total procedure times were recorded. All three groups showed no statistical difference for age, sex ratio, procedure priority or indication. The mean volume of flush required to obtain clear mucosa was significantly less in the solution group compared with the other groups. The mean overall procedure time was also less in the solution group compared with the other groups. Premedication with N-acetylcysteine and simethicone markedly improves mucosal visibility during gastroscopy. It also reduces the time taken for the procedure. This low-cost and well-tolerated intervention may improve detection of early neoplasia.

  19. Sensory aspects of drinking water in contact with epoxy lined copper pipe.

    PubMed

    Heim, T H; Dietrich, A M

    2007-01-01

    Pipe relining via in situ epoxy lining is used to remediate corroded plumbing or distribution systems. This investigation examined the effects on odour, TOC, THM formation and disinfectant demand in water exposed to epoxy-lined copper pipes used for home plumbing. The study was conducted in accordance with the Utility Quick Test, a migration/leaching method for utilities to conduct sensory analysis of materials in contact with drinking water. The test was performed using water with no disinfectant and levels of chlorine and monochloramines representative of those found in the distribution system. Panelists repeatedly and consistently described a "plastic/adhesive/putty" odour in the water from the pipes. The odour intensity remained relatively constant for each of two subsequent flushes. Water samples stored in the epoxy-lined pipes showed a significant increase in the leaching of organic compounds (as TOC), and this TOC was demonstrated to react with free chlorine to form trichloromethane. Water stored in the pipes also showed a marked increase in disinfectant demand relative to the water stored in glass control flasks. A study conducted at a full scale installation at an apartment demonstrated that after installation and regular use, the epoxy lining did not yield detectable differences in water quality.

  20. Contributions to the design of rainwater harvesting systems in buildings with green roofs in a Mediterranean climate.

    PubMed

    Monteiro, Cristina M; Calheiros, Cristina S C; Pimentel-Rodrigues, Carla; Silva-Afonso, Armando; Castro, Paula M L

    2016-01-01

    Green roofs (GRs) are becoming a trend in urban areas, favouring thermal performance of buildings, promoting removal of atmospheric pollutants, and acting as possible water collection spots. Rainwater harvesting systems in buildings can also contribute to the management of stormwater runoff reducing flood peaks. These technologies should be enhanced in Mediterranean countries where water scarcity is increasing and the occurrence of extreme events is becoming very significant, as a result of climate change. An extensive pilot GR with three aromatic plant species, Satureja montana, Thymus caespititius and Thymus pseudolanuginosus, designed to study several parameters affecting rainwater runoff, has been in operation for 12 months. Physico-chemical analyses of roof water runoff (turbidity, pH, conductivity, NH4(+), NO3(-), PO4(3-), chemical oxygen demand) have shown that water was of sufficient quality for non-potable uses in buildings, such as toilet flushing. An innovative approach allowed for the development of an expression to predict a 'monthly runoff coefficient' of the GR system. This parameter is essential when planning and designing GRs combined with rainwater harvesting systems in a Mediterranean climate. This study is a contribution to improving the basis for the design of rainwater harvesting systems in buildings with extensive GRs under a Mediterranean climate.

  1. Unsteady state flow and stagnation in distribution systems affect the biological stability of drinking water.

    PubMed

    Manuel, C M; Nunes, O C; Melo, L F

    2010-01-01

    The effects of water stagnation and flushing on the biological stability of drinking water were studied by promoting the formation of biofilms under continuous flow (turbulent or laminar) and subsequently subjecting them to unsteady hydraulic situations. Independently of the flow regime under which the biofilm was formed, stagnation promoted bacterial accumulation, either in attached or suspended form, which were carried away in higher numbers when flow was re-started, thereby compromising its biological quality. In all cases, Betaproteobacteria was the dominant phylogenetic group, although Gamma and Alpha subclasses were also present. These results suggest that special attention should be given to the biological quality of drinking water where consumption is subjected to strongly variable demands such as in seasonal hotels, week-end houses or dental clinics after week-ends as abnormal changes may have occurred in the microbiological parameters. Moreover, this study showed that the cultivable bacterial numbers are not related to those of total bacteria and, thus, should not be the basis for the routine tests of bacteriological control in these systems.

  2. The performance of a mobile air conditioning system with a water cooled condenser

    NASA Astrophysics Data System (ADS)

    Di Battista, Davide; Cipollone, Roberto

    2015-11-01

    Vehicle technological evolution lived, in recent years, a strong acceleration due to the increased awareness of environmental issues related to pollutants and climate altering emissions. This resulted in a series of international regulations on automotive sector which put technical challenges that must consider the engine and the vehicle as a global system, in order to improve the overall efficiency of the system. The air conditioning system of the cabin, for instance, is the one of the most important auxiliaries in a vehicle and requires significant powers. Its performances can be significantly improved if it is integrated within the engine cooling circuit, eventually modified with more temperature levels. In this paper, the Authors present a mathematical model of the A/C system, starting from its single components: compressors, condenser, flush valve and evaporator and a comparison between different refrigerant fluid. In particular, it is introduced the opportunity to have an A/C condenser cooled by a water circuit instead of the external air linked to the vehicle speed, as in the actual traditional configuration. The A/C condenser, in fact, could be housed on a low temperature water circuit, reducing the condensing temperature of the refrigeration cycle with a considerable efficiency increase.

  3. The educational potential of alcohol-related flushing among Chinese young people

    PubMed Central

    Shell, Duane F.; Huang, Zhaoqing; Qian, Ling

    2015-01-01

    Aim: This paper describes Chinese university students' understanding of the meaning of the alcohol-related flushing response and how they reacted to their own and someone else's flushing in a group drinking situation. Method: The researcher surveyed 530 Chinese university students about their understanding of flushing and their perception of how people respond to a person who visibly flushes while drinking alcohol. Findings: Most students did not know about the physiological cause of flushing. There were significant gender differences in both reactions to and perception of responses to a person who flushes. There was no direct relationship between flushing and drinking behaviour. Conclusions: This description of flushing behaviour and responses to a flushing person is discussed in terms of educational opportunities to change behaviours that could reduce the cancer related risks of this visibly at-risk group. PMID:25983401

  4. Assessing Pathogen Levels in Dairy Lagoon Wastewater and Potential Evaporation Losses

    NASA Astrophysics Data System (ADS)

    Pandey, P.; Biswas, S.; Souza, A.; Silva-del-Rio, N.; Vaddella, V. K.; Castillo, A. R.

    2014-12-01

    The ongoing drought in California necessitates the conservation of existing water resources while protecting the water quality. There is a critical need to improve the understanding of evaporation losses from dairy lagoons in California, and their corresponding changes in pathogen levels in the lagoon wastewater. We have carried out preliminary studies involving extensive dairy lagoon water sampling, and batch-scale experiments. The dairy wastewater was collected from both primary and secondary lagoons in three counties of California (Merced, Tulare, and Glenn Counties) for enumerating the levels of E. coli O157:H7, Salmonella spp., and Listeria monocytogenes. Subsequently, we conducted batch-scale experiments at mesophilic (31 and 37 ⁰C) and thermophilic temperatures (43 and 49 ⁰C) to understand the E. coli O157:H7 inactivation process and potential evaporative water losses. In addition, we compared the evaporation losses under the environment of biological activity and the environment of restricted biological activity (extreme environment with low pH). For E. coli O157:H7 enumeration, we used MacConkey agar, while for Salmonella spp., XLD agar was used. Listeria monocytogenes levels were measured using PALCAM agar (with selective supplement). In flushed dairy wastewater (fresh) samples, the average of E. coli O157:H7 levels were 2 × 104 CFU/mL. The average Listeria monocytogenes levels in flushed manure were 9 × 101. The levels of Salmonella spp. were non-detectable. In mesophilic condition (37 ⁰C) after 5 days of incubation, 8% of total water loss was observed, while at thermophilic temperature (49 ⁰C), 70% of total water loss was observed. After 5 days of incubation at 37 ⁰C, E. coli O157:H7 levels in flushed dairy manure were increased from 2.8 × 103 to 5.2 × 104 CFU/mL, while at 49 ⁰C, E. coli O157:H7 levels were reduced from 2.8 × 103 to 5 × 101 CFU/mL after 4 days of incubation. We anticipate that the results of this study would be useful in understanding the dynamics of water losses and pathogen inactivation in dairy lagoon wastewater.

  5. Spatial optimization for decentralized non-potable water reuse

    NASA Astrophysics Data System (ADS)

    Kavvada, Olga; Nelson, Kara L.; Horvath, Arpad

    2018-06-01

    Decentralization has the potential to reduce the scale of the piped distribution network needed to enable non-potable water reuse (NPR) in urban areas by producing recycled water closer to its point of use. However, tradeoffs exist between the economies of scale of treatment facilities and the size of the conveyance infrastructure, including energy for upgradient distribution of recycled water. To adequately capture the impacts from distribution pipes and pumping requirements, site-specific conditions must be accounted for. In this study, a generalized framework (a heuristic modeling approach using geospatial algorithms) is developed that estimates the financial cost, the energy use, and the greenhouse gas emissions associated with NPR (for toilet flushing) as a function of scale of treatment and conveyance networks with the goal of determining the optimal degree of decentralization. A decision-support platform is developed to assess and visualize NPR system designs considering topography, economies of scale, and building size. The platform can be used for scenario development to explore the optimal system size based on the layout of current or new buildings. The model also promotes technology innovation by facilitating the systems-level comparison of options to lower costs, improve energy efficiency, and lower greenhouse gas emissions.

  6. Characterization and release profile of (Mn, Al)-bearing deposits in drinking water distribution systems.

    PubMed

    Li, Guiwei; Ding, Yuanxun; Xu, Hongfu; Jin, Junwei; Shi, Baoyou

    2018-04-01

    Inorganic contaminants accumulation in drinking water distribution systems (DWDS) is a great threat to water quality and safety. This work assessed the main risk factors for different water pipes and discovered the release profile of accumulated materials in a full scale distribution system frequently suffered from water discoloration problem. Physicochemical characterization of pipe deposits were performed using X-ray fluorescence, scanning electron microscopy, X-ray diffraction, X-ray photoelectron spectroscopy and Fourier transform infrared spectroscopy. The metal release profile was obtained through continuous monitoring of a full-scale DWDS area. The results showed that aluminum and manganese were the main metals of deposits in nonmetallic pipes, while iron was dominant in iron-based pipe corrosion scales. Manganese primarily existed as MnO 2 without well crystalline form. The relative abundance of Mn and Fe in deposits changed with their distance from the water treatment plant. Compared with iron in corrosion scales, Mn and Al were more labile to be released back into bulk water during unidirectional flushing process. A main finding of this work is the co-release behavior of Mn and Al in particulate form and significant correlation exists between these two metals. Dual control of manganese and aluminum in treated water is proposed to be essential to cope with discoloration and trace metal contamination in DWDS. Copyright © 2018 Elsevier Ltd. All rights reserved.

  7. Hydrogeology and Migration of Septic-Tank Effluent in the Surficial Aquifer System in the Northern Midlands Area, Palm Beach County, Florida

    USGS Publications Warehouse

    Miller, Wesley L.

    1992-01-01

    The northern Midlands area in Palm Beach County is an area of expected residential growth, but its flat topography, poor drainage, and near-surface marl layers retard rainfall infiltration and cause frequent flooding. Public water supplies and sewer services are not planned for the area, thus, residents must rely on domestic wells and septic tanks. The water table in the northern Midlands area is seldom more than 5 feet below land surface, and regional ground-water flows are east, southwest, and south from the north-central part of the area where ground-water levels are highest. Ground-water quality in the western part of the area and in the Loxahatchee Slough is greatly influenced by residual seawater emplaced during the Pleistocene Epoch. Chloride and dissolved-solids concentrations of ground water in the surficial aquifer system in these areas often exceed secondary drinking-water standards. Residual seawater has been more effectively flushed from the more permeable sediments elsewhere in the eastern and southwestern parts of the study area. Test at three septic-tank sites showed traces of effluent in ground water (38-92 feet from the septic tank outlets) and that near-surface marl layers greatly impede the downward migration of the effluent in the surficial aquifer system throughout the northern midlands.

  8. Hot flushes in healthy aging men differ from those in men with prostate cancer and in menopausal women.

    PubMed

    Holm, Anna-Clara Spetz; Thorell, Lars-Håkan; Theodorsson, Elvar; Hammar, Mats

    2012-01-01

    Calcitonin gene-related peptide (CGRP) seems to be involved in hot flushes in women and in castrated men. Therefore, we studied whether the plasma concentrations of CGRP changed during flushes in a group of healthy aging men. Twelve men (49-71 years) with no history of current or former prostate cancer or hormonal treatment reporting ≥ 20 flushes/week were investigated. Blood samples were drawn during and between flushes for analysis of CGRP and also androgen concentrations, that is, testosterone and bioavailable testosterone were analysed. Skin temperature and skin conductance were monitored. Thirty-five flushes were reported by 10 men. The plasma concentrations of CGRP did not increase during flushes. No significant change in skin temperature or conductance was found. CGRP is probably not involved in the mechanisms of flushes in healthy aging men. Therefore, flushes in aging healthy men seem to be different from flushes in men and women deprived of sex steroids where CGRP increases during flushes.

  9. Analysis and Results from a Flush Airdata Sensing System in Close Proximity to Firing Rocket Nozzles

    NASA Technical Reports Server (NTRS)

    Ali, Aliyah N.; Borrer, Jerry L.

    2013-01-01

    This paper presents information regarding the nosecap Flush Airdata Sensing (FADS) system on Orion’s Pad Abort 1 (PA-1) vehicle. The purpose of the nosecap FADS system was to test whether or not useful data could be obtained from a FADS system if it was placed in close proximity to firing rocket nozzles like the Attitude Control Motor (ACM) nozzles on the PA-1 Launch Abort System. The nosecap FADS system used pressure measurements from a series of pressure ports which were arranged in a cruciform pattern and flush with the surface of the vehicle to estimate values of angle of attack, angle of sideslip, Mach number, impact pressure, and freestream static pressure. This paper will present the algorithms employed by the FADS system along with the development of the calibration datasets and a comparison of the final results to the Best Estimated Trajectory (BET) data for PA-1. Also presented in this paper is a Computational Fluid Dynamics (CFD) study to explore the impact of the ACM on the nosecap FADS system. The comparison of the nosecap FADS system results to the BET and the CFD study showed that more investigation is needed to quantify the impact of the firing rocket motors on the FADS system.

  10. Comparing the efficacy of four immersion flush and static hydorgen peroxide and copper sulfate treatments on channel catfish eggs infected with water molds

    USDA-ARS?s Scientific Manuscript database

    Water mold infestations on channel catfish eggs lower the hatch rate (egg survival) and ultimately the number of catfish fry available for stocking in production ponds. This study compared the potential of two hydrogen peroxide (HP) and two copper sulfate pentahydrate (CSP) treatments to increase c...

  11. Numerical study of water residence time in the Yueqing Bay based on the eulerian approach

    NASA Astrophysics Data System (ADS)

    Ying, Chao; Li, Xinwen; Liu, Yong; Yao, Wenwei; Li, Ruijie

    2018-05-01

    The Yueqing Bay was a semi-enclosed bay located in the southeast of Zhejiang Province, China. Due to substantial anthropogenic influences since 1964, the water quality in the bay had deteriorated seriously. Thus urgent measures should be taken to protect the water body. In this study, a numerical model was calibrated for water surface elevation and tidal current from August 14 to August 26, 2011. Comparisons of observed and simulated data showed that the model reproduced the tidal range and phase and the variations of current at different periods fairly well. The calibrated model was then applied to investigate spatial flushing pattern of the bay by calculation of residence time. The results obtained from a series of model experiments demonstrated that the residence time increased from 10 day at the bay mouth to more than 70 day at the upper bay. The average residence time over the whole bay was 49.5 day. In addition, the adaptation of flushing homogeneity curve showed that the residence time in the bay varied smoothly. This study provides a numerical tool to quantify the transport timescale in Yueqing Bay and supports adaptive management of the bay by local authorities.

  12. FLUSH: A tool for the design of slush hydrogen flow systems

    NASA Technical Reports Server (NTRS)

    Hardy, Terry L.

    1990-01-01

    As part of the National Aerospace Plane Project an analytical model was developed to perform calculations for in-line transfer of solid-liquid mixtures of hydrogen. This code, called FLUSH, calculates pressure drop and solid fraction loss for the flow of slush hydrogen through pipe systems. The model solves the steady-state, one-dimensional equation of energy to obtain slush loss estimates. A description of the code is provided as well as a guide for users of the program. Preliminary results are also presented showing the anticipated degradation of slush hydrogen solid content for various piping systems.

  13. The Response of a Branch of Puget Sound, Washington to the 2014 North Pacific Warm Anomaly

    NASA Astrophysics Data System (ADS)

    Mickett, J.; Newton, J.; Devol, A.; Krembs, C.; Ruef, W.

    2016-02-01

    The flow of the unprecedentedly-warm upper-ocean North Pacific "Blob" water into Puget Sound, Washington, caused local extreme water property anomalies that extended from the arrival of the water inshore in the fall of 2014 through 2015. Here we report on moored and seaplane observations from Hood Canal, a branch of Puget Sound, where temperature was more than 2σ above climatology for much of the year with maximum temperature anomalies at depth and at the surface +2.5 °C and +7 °C respectively. The low density of the oceanic warm "Blob" water resulted in weak deep water flushing in Hood Canal in the fall of 2014, which combined with a lack of wintertime flushing to result in anomalously-low dissolved oxygen (DO) concentrations at depth. Late-summer 2015 DO values were the lowest in a decade of mooring observations and more than 2σ below climatology. The anomalously low density of the deep basin water allowed a very early onset of the annually-occurring, late-summer intrusion, which first entered Hood Canal at the end of July compared to the usual arrival in early to mid-September. In late August this intrusion conspired with an early fall storm to lift the very low DO deep water to surface at the south end of Hood Canal, causing a significant fish kill event.

  14. The use of water-soluble mucoadhesive gels for the intravesical delivery of epirubicin to the bladder for the treatment of non-muscle-invasive bladder cancer.

    PubMed

    Chatta, Dani; Cottrell, Lewis; Burnett, Bruce; Laverty, Garry; McConville, Christopher

    2015-10-01

    To develop an epirubicin-loaded, water-soluble mucoadhesive gels that have the correct rheological properties to facilitate their delivery into the bladder via a catheter, while allowing for their spread across the bladder wall with limited expansion of the bladder and increasing the retention of epirubicin in the bladder and flushing with urine. Epirubicin-loaded hydroxyl ethyl cellulose (HEC) and hydroxy propyl methyl cellulose (HPMC) gels were manufactured and tested for their rheological properties. Their ability to be pushed through a catheter was also assessed as was their in-vitro drug release, spreading in a bladder and retention of epirubicin after flushing with simulated urine. Epirubicin drug release was viscosity-dependent. The 1 and 1.5% HEC gels and the 1, 1.5 and 2% HPMC gels had the correct viscosity to be administered through a model catheter and spread evenly across the bladder wall under the pressure of the detrusor muscle. The epirubicin-loaded gels had an increased retention time in the bladder when compared with a standard intravesical solution of epirubicin, even after successive flushes with simulated urine. The increased retention of epirubicin in the bladder by the HEC and HPMC gels warrant further investigation, using an in-vivo model, to assess their potential for use as treatment for non-muscle-invasive bladder cancer. © 2015 Royal Pharmaceutical Society.

  15. Biodegradability of organic matter associated with sewer sediments during first flush.

    PubMed

    Sakrabani, Ruben; Vollertsen, Jes; Ashley, Richard M; Hvitved-Jacobsen, Thorkild

    2009-04-01

    The high pollution load in wastewater at the beginning of a rain event is commonly known to originate from the erosion of sewer sediments due to the increased flow rate under storm weather conditions. It is essential to characterize the biodegradability of organic matter during a storm event in order to quantify the effect it can have further downstream to the receiving water via discharges from Combined Sewer Overflow (CSO). The approach is to characterize the pollutograph during first flush. The pollutograph shows the variation in COD and TSS during a first flush event. These parameters measure the quantity of organic matter present. However these parameters do not indicate detailed information on the biodegradability of the organic matter. Such detailed knowledge can be obtained by dividing the total COD into fractions with different microbial properties. To do so oxygen uptake rate (OUR) measurements on batches of wastewater have shown itself to be a versatile technique. Together with a conceptual understanding of the microbial transformation taking place, OUR measurements lead to the desired fractionation of the COD. OUR results indicated that the highest biodegradability is associated with the initial part of a storm event. The information on physical and biological processes in the sewer can be used to better manage sediment in sewers which can otherwise result in depletion of dissolved oxygen in receiving waters via discharges from CSOs.

  16. New Technology for Oil/Water Emulsion Treatment: Phases I and II

    DTIC Science & Technology

    1998-05-15

    m.(Aŕ) Emulsions have long been of practical interest because of their extensive everyday applications. Emulsions are used in foods ( milk and...separating cream from milk . Valve-discharge centrifuges periodically discharge accumulated solids. Split-bowl centrifuges have a bowl that allows...fresh air. Call a physician. RVF CONTACT: Flush with water for 15 minutes. Call a physician. Wash thSroSghly with soap and rinse with water. Call

  17. Stable Algorithm For Estimating Airdata From Flush Surface Pressure Measurements

    NASA Technical Reports Server (NTRS)

    Whitmore, Stephen, A. (Inventor); Cobleigh, Brent R. (Inventor); Haering, Edward A., Jr. (Inventor)

    2001-01-01

    An airdata estimation and evaluation system and method, including a stable algorithm for estimating airdata from nonintrusive surface pressure measurements. The airdata estimation and evaluation system is preferably implemented in a flush airdata sensing (FADS) system. The system and method of the present invention take a flow model equation and transform it into a triples formulation equation. The triples formulation equation eliminates the pressure related states from the flow model equation by strategically taking the differences of three surface pressures, known as triples. This triples formulation equation is then used to accurately estimate and compute vital airdata from nonintrusive surface pressure measurements.

  18. Nutrients in estuaries--an overview and the potential impacts of climate change.

    PubMed

    Statham, Peter J

    2012-09-15

    The fate and cycling of macronutrients introduced into estuaries depend upon a range of interlinked processes. Hydrodynamics and morphology in combination with freshwater inflow control the freshwater flushing time, and the timescale for biogeochemical processes to operate that include microbial activity, particle-dissolved phase interactions, and benthic exchanges. In some systems atmospheric inputs and exchanges with coastal waters can also be important. Climate change will affect nutrient inputs and behaviour through modifications to temperature, wind patterns, the hydrological cycle, and sea level rise. Resulting impacts include: 1) inundation of freshwater systems 2) changes in stratification, flushing times and phytoplankton productivity 3) increased coastal storm activity 4) changes in species and ecosystem function. A combination of continuing high inputs of nutrients through human activity and climate change is anticipated to lead to enhanced eutrophication in the future. The most obvious impacts of increasing global temperature will be in sub-arctic systems where permafrost zones will be reduced in combination with enhanced inputs from glacial systems. Improved process understanding in several key areas including cycling of organic N and P, benthic exchanges, resuspension, impact of bio-irrigation, particle interactions, submarine groundwater discharges, and rates and magnitude of bacterially-driven recycling processes, is needed. Development of high frequency in situ nutrient analysis systems will provide data to improve predictive models that need to incorporate a wider variety of key factors, although the complexity of estuarine systems makes such modelling a challenge. However, overall a more holistic approach is needed to effectively understand, predict and manage the impact of macronutrients on estuaries. Copyright © 2011 Elsevier B.V. All rights reserved.

  19. Molecular survey of the occurrence of Legionella spp., Mycobacterium spp., Pseudomonas aeruginosa, and amoeba hosts in two chloraminated drinking water distribution systems.

    PubMed

    Wang, Hong; Edwards, Marc; Falkinham, Joseph O; Pruden, Amy

    2012-09-01

    The spread of opportunistic pathogens via public water systems is of growing concern. The purpose of this study was to identify patterns of occurrence among three opportunistic pathogens (Legionella pneumophila, Mycobacterium avium, and Pseudomonas aeruginosa) relative to biotic and abiotic factors in two representative chloraminated drinking water distribution systems using culture-independent methods. Generally, a high occurrence of Legionella (≥69.0%) and mycobacteria (100%), lower occurrence of L. pneumophila (≤20%) and M. avium (≤33.3%), and rare detection of Pseudomonas aeruginosa (≤13.3%) were observed in both systems according to quantitative PCR. Also, Hartmanella vermiformis was more prevalent than Acanthamoeba, both of which are known hosts for opportunistic pathogen amplification, the latter itself containing pathogenic members. Three-minute flushing served to distinguish distribution system water from plumbing in buildings (i.e., premise plumbing water) and resulted in reduced numbers of copies of Legionella, mycobacteria, H. vermiformis, and 16S rRNA genes (P < 0.05) while yielding distinct terminal restriction fragment polymorphism (T-RFLP) profiles of 16S rRNA genes. Within certain subgroups of samples, some positive correlations, including correlations of numbers of mycobacteria and total bacteria (16S rRNA genes), H. vermiformis and total bacteria, mycobacteria and H. vermiformis, and Legionella and H. vermiformis, were noted, emphasizing potential microbial ecological relationships. Overall, the results provide insight into factors that may aid in controlling opportunistic pathogen proliferation in real-world water systems.

  20. Molecular Survey of the Occurrence of Legionella spp., Mycobacterium spp., Pseudomonas aeruginosa, and Amoeba Hosts in Two Chloraminated Drinking Water Distribution Systems

    PubMed Central

    Wang, Hong; Edwards, Marc; Falkinham, Joseph O.

    2012-01-01

    The spread of opportunistic pathogens via public water systems is of growing concern. The purpose of this study was to identify patterns of occurrence among three opportunistic pathogens (Legionella pneumophila, Mycobacterium avium, and Pseudomonas aeruginosa) relative to biotic and abiotic factors in two representative chloraminated drinking water distribution systems using culture-independent methods. Generally, a high occurrence of Legionella (≥69.0%) and mycobacteria (100%), lower occurrence of L. pneumophila (≤20%) and M. avium (≤33.3%), and rare detection of Pseudomonas aeruginosa (≤13.3%) were observed in both systems according to quantitative PCR. Also, Hartmanella vermiformis was more prevalent than Acanthamoeba, both of which are known hosts for opportunistic pathogen amplification, the latter itself containing pathogenic members. Three-minute flushing served to distinguish distribution system water from plumbing in buildings (i.e., premise plumbing water) and resulted in reduced numbers of copies of Legionella, mycobacteria, H. vermiformis, and 16S rRNA genes (P < 0.05) while yielding distinct terminal restriction fragment polymorphism (T-RFLP) profiles of 16S rRNA genes. Within certain subgroups of samples, some positive correlations, including correlations of numbers of mycobacteria and total bacteria (16S rRNA genes), H. vermiformis and total bacteria, mycobacteria and H. vermiformis, and Legionella and H. vermiformis, were noted, emphasizing potential microbial ecological relationships. Overall, the results provide insight into factors that may aid in controlling opportunistic pathogen proliferation in real-world water systems. PMID:22752174

  1. Accidental contamination of a German town's drinking water with sodium hydroxide.

    PubMed

    Lendowski, Luba; Färber, Harald; Holy, Andreas; Darius, Anke; Ehrich, Bernd; Wippermann, Christine; Küfner, Bernd; Exner, Martin

    2015-05-01

    Case report of a very serious drinking water incident putting up to 50,000 inhabitants of a town near Bonn in North Rhine-Westphalia, Germany at risk. A concentrated solution of highly alkaline water by sodium hydroxide was accidentally washed into the town's drinking water at a pumping station and increased the pH-value of the water to 12. Residents who came into contact with the contaminated water immediately had a toxic reaction. The incident was detected by complaints from customers and after that was stopped within several hours. The pipes were flushed and the customers were warned not to use the water till the all clear. After this immediate management there was an investigation and the cause of the incident was detected as an accidental release of accumulated sodium hydroxide (NaOH) solution. The lack of a network alarm system and the automatic cut-off mechanisms as deficiencies in the design of the station were rectified by the water company immediately after the incident. Copyright © 2015 Elsevier GmbH. All rights reserved.

  2. Variability of invertebrate abundance in drinking water distribution systems in the Netherlands in relation to biostability and sediment volumes.

    PubMed

    van Lieverloo, J Hein M; Hoogenboezem, Wim; Veenendaal, Gerrit; van der Kooij, Dick

    2012-10-15

    A survey of invertebrates in drinking water from treatment works, internal taps and hydrants on mains was carried out by almost all water companies in the Netherlands from September 1993 to August 1995. Aquatic sow bugs (Asellidae, 1-12 mm) and oligochaeta worms (Oligochaeta, 1-100 mm), both known to have caused rare though embarrassing consumer complaints, were found to form 98% of the mean biomass in water flushed from mains. Their numbers in the mains water ranged up to 1500 (mean 37) Asellidae m(-3) and up to 9900 (mean 135) Oligochaeta m(-3). Smaller crustaceans (0.5-2 mm) dominated the numbers in water from mains. e.g. water fleas (Cladocera and Copepoda up to 14,000 m(-3)). Common invertebrates in treated water and in tap water were Rotifera (<1 mm) and nematode worms (Nematoda, <2 mm). No Asellidae, large Oligochaeta (>5 mm) or other large invertebrates were found in 1560 samples of 200 l treated water or tap water. Large variations in invertebrate abundance were found within and between distribution systems. Of the variability of mean biomass in mains per system, 55%, 60% and 63% could statistically be explained by differences in the Biofilm Formation Rate, non-particulate organic matter and the permanganate index of the treated water of the treatment works respectively. A similar correlation was found between mean invertebrate biomass and mean sediment volumes in the distribution systems (R(2) = 52%). Copyright © 2012 Elsevier Ltd. All rights reserved.

  3. Long-term isolation and local adaptation in Palau's Nikko Bay help corals thrive in acidic waters

    NASA Astrophysics Data System (ADS)

    Golbuu, Yimnang; Gouezo, Marine; Kurihara, Haruko; Rehm, Lincoln; Wolanski, Eric

    2016-09-01

    The reefs in Palau's Nikko Bay live in seawater with low pH that is similar to conditions predicted for 2100 because of ocean acidification. Nevertheless, the reefs at Nikko Bay have high coral cover and high diversity. We hypothesize that the low-pH environment in Nikko Bay is caused by low flushing rates, which causes long-term isolation and local adaptation. To test this hypothesis, we modeled the water circulation in and around Nikko Bay. Model results show that average residence time is 71 d, which is ten times the residence time on fore-reef habitats. The long residence time restricts the exchange of coral larvae in the bay with adjacent reefs, allowing persistent selection for tolerant traits and local adaptation. The corals in Nikko Bay are also more susceptible to local pollution because the waters are poorly flushed. Therefore, local management must focus on minimizing human impacts such as dredging, overfishing and pollution in the bay, which would compromise the condition of the corals that have already adapted to low-pH conditions.

  4. Seasonal Variation in Drinking and Domestic Water Sources and Quality in Port Harcourt, Nigeria.

    PubMed

    Kumpel, Emily; Cock-Esteb, Alicea; Duret, Michel; de Waal, Dominick; Khush, Ranjiv

    2017-02-08

    We compared dry and rainy season water sources and their quality in the urban region of Port Harcourt, Nigeria. Representative sampling indicated that municipal water supplies represent < 1% of the water sources. Residents rely on privately constructed and maintained boreholes that are supplemented by commercially packaged bottled and sachet drinking water. Contamination by thermotolerant coliforms increased from 21% of drinking water sources in the dry season to 42% of drinking water sources in the rainy season ( N = 356 and N = 397). The most significant increase was in sachet water, which showed the lowest frequencies of contamination in the dry season compared with other sources (15%, N = 186) but the highest frequencies during the rainy season (59%, N = 76). Only half as many respondents reported drinking sachet water in the rainy season as in the dry season. Respondents primarily used flush or pour-flush toilets connected to septic tanks (85%, N = 399). The remainder relied on pit latrines and hanging (pier) latrines that drained into surface waters. We found significant associations between fecal contamination in boreholes and the nearby presence of hanging latrines. Sanitary surveys of boreholes showed that more than half were well-constructed, and we did not identify associations between structural or site deficiencies and microbial water quality. The deterioration of drinking water quality during the rainy season is a serious public health risk for both untreated groundwater and commercially packaged water, highlighting a need to address gaps in monitoring and quality control. © The American Society of Tropical Medicine and Hygiene.

  5. Physicochemical Approaches for the Remediation of Former Manufactured Gas Plant Tars

    NASA Astrophysics Data System (ADS)

    Hauswirth, S.; Miller, C. T.

    2014-12-01

    Former manufactured gas plant (FMGP) tars are one of the most challenging non-aqueous phase liquid (NAPL) contaminants to remediate due to their complex chemical composition, high viscosities, and ability to alter wettability. In this work, we investigate several in situ remediation techniques for the removal of tar from porous media. Batch and column experiments were conducted to test the effectiveness of mobilization, solubilization, and chemical oxidation remediation approaches. Alkaline (NaOH), surfactant (Triton X-100), and polymer (xanthan gum) agents were used in various combinations to reduce tar-water interfacial tension, increase flushing solution viscosity, and increase the solubilities of tar components. Base-activated sodium persulfate was used alone and in combination with surfactant to chemically oxidized tar components. The effectiveness of each method was assessed in terms of both removal of PAHs from the system and reduction of dissolved-phase effluent polycyclic aromatic hydrocarbon (PAH) concentrations. In column studies, alkaline-polymer (AP) and alkaline-surfactant-polymer (ASP) solutions efficiently mobilized 81-93% and 95-96% of residual PAHs, respectively, within two pore volumes. The impact of AP flushing on dissolved-phase PAH concentrations was relatively low; however, the concentrations of several low molar mass PAHs were significantly reduced after ASP flushing. Surfactant-polymer (SP) solutions removed over 99% of residual PAHs through a combination of mobilization and solubilization, and reduced the post-remediation, dissolved-phase total PAH concentration by 98.4-99.1%. Degradation of residual PAHs by base-activated sodium persulfate was relatively low (30-50%), and had little impact on dissolved-phase PAH concentrations.

  6. The Military Deployment Human Exposure Assessment Study (MDHEXAS): Blood and Urine Exposure Biomarkers as Environmental Surveillance Tools for Assessing Military Personnel Exposure to Chemicals During Deployment to Camp McGovern, Bosnia

    DTIC Science & Technology

    2003-01-01

    dysp = Dyspnea euph = euphoria excitement = excited fib = fibrosis flush face = flush face ftg = fatigue Head = Headache Gidd = giddiness inco...nausea Neck = neck ache nose = irritated nose Pallor Pulm edema= pulmonar y edema Resp sys = Respiratory System skin = irritated skin som = somnolence

  7. Short- and Long-Term Lead Release after Partial Lead Service Line Replacements in a Metropolitan Water Distribution System.

    PubMed

    Deshommes, Elise; Laroche, Laurent; Deveau, Dominique; Nour, Shokoufeh; Prévost, Michèle

    2017-09-05

    Thirty-three households were monitored in a full-scale water distribution system, to investigate the impact of recent (<2 yr) or old partial lead service line replacements (PLSLRs). Total and particulate lead concentrations were measured using repeat sampling over a period of 1-20 months. Point-of-entry filters were installed to capture sporadic release of particulate lead from the lead service lines (LSLs). Mean concentrations increased immediately after PLSLRs and erratic particulate lead spikes were observed over the 18 month post-PLSLR monitoring period. The mass of lead released during this time frame indicates the occurrence of galvanic corrosion and scale destabilization. System-wide, lead concentrations were however lower in households with PLSLRs as compared to those with no replacement, especially for old PLSLRs. Nonetheless, 61% of PLSLR samples still exceeded 10 μg/L, reflecting the importance of implementing full LSL replacement and efficient risk communication. Acute concentrations measured immediately after PLSLRs demonstrate the need for appropriate flushing procedures to prevent lead poisoning.

  8. Tree leaf control on low flow water quality in a small Virginia stream

    USGS Publications Warehouse

    Slack, K.V.; Feltz, H.R.

    1968-01-01

    Impaired water quality in a small stream was related to autumn leaf fall from riparian vegetation. Dissolved oxygen and pH decreased, and water color, specific conductance, iron, manganese, and bicarbonate values increased as the rate of leaf fall increased. Similar quality changes occurred in laboratory cultures of tree leaves in filtered stream water, but the five leaf species studied produced widely differing results. Stream quality improved rapidly following channel flushing by storm flow. Organic loading by tree litter can exert significant control on water composition, especially during low flow.

  9. Rugged large volume injection for sensitive capillary LC-MS environmental monitoring

    NASA Astrophysics Data System (ADS)

    Roberg-Larsen, Hanne; Abele, Silvija; Demir, Deniz; Dzabijeva, Diana; Amundsen, Sunniva F.; Wilson, Steven R.; Bartkevics, Vadims; Lundanes, Elsa

    2017-08-01

    A rugged and high throughput capillary column (cLC) LC-MS switching platform using large volume injection and on-line automatic filtration and filter back-flush (AFFL) solid phase extraction (SPE) for analysis of environmental water samples with minimal sample preparation is presented. Although narrow columns and on-line sample preparation are used in the platform, high ruggedness is achieved e.g. injection of 100 non-filtrated water samples would did not result in a pressure rise/clogging of the SPE/capillary columns (inner diameter 300 µm). In addition, satisfactory retention time stability and chromatographic resolution were also features of the system. The potential of the platform for environmental water samples was demonstrated with various pharmaceutical products, which had detection limits (LOD) in the 0.05 - 12.5 ng/L range. Between-day and within-day repeatability of selected analytes were < 20% RSD.

  10. Diverse patterns of stored water use among saplings in seasonally dry tropical forests.

    PubMed

    Wolfe, Brett T; Kursar, Thomas A

    2015-12-01

    Tree species in seasonally dry tropical forests likely vary in their drought-survival mechanisms. Drought-deciduousness, which reduces water loss, and low wood density, which may permit dependence on stored water, are considered key traits. For saplings of six species at two distinct sites, we studied these and two associated traits: the seasonal amount of water released per stem volume ("water released") and the hydraulic capacitance of the stem (C). Two deciduous species with low stem density, Cavanillesia platanifolia and Bursera simaruba, had high C and high dry-season stem water potential (Ψ(stem)), but differed in dry-season water released. C. platanifolia did not use stored water during the dry season whereas B. simaruba, in a drier forest, released stored water. In both, water released was highest while flushing leaves, suggesting that stored water supports leaf flushing. In contrast, two deciduous species with intermediate stem density, Annona hayesii and Genipa americana, had intermediate C, low dry-season Ψ(stem), and high seasonal change in water released. Meanwhile, two evergreen species with intermediate stem density, Cojoba rufescens and Astronium graveolens, had relatively low C, low dry-season Ψ(stem), and intermediate seasonal change in water released. Thus, at least three, distinct stored-water-use strategies were observed. Additionally, bark relative water content (RWC) decreased along with Ψ(stem) during the dry season while xylem RWC did not change, suggesting that bark-stored water buffers Ψ(stem) seasonally. Together these results suggest that seasonal use of stored water and change in Ψ(stem) are associated with functional groups that are characterized by combinations of deciduousness and stem density.

  11. Re-thinking wastewater landscapes: combining innovative strategies to address tomorrow's urban wastewater treatment challenges.

    PubMed

    Smith, B R

    2009-01-01

    Most major cities worldwide face urban water management challenges relating to drinking supply, stormwater and wastewater treatment, and ecological preservation. In light of climate change and finite natural resources, addressing these challenges in sustainable ways will require innovative solutions arising from interdisciplinary collaboration. This article summarizes five major urban water management strategies that bridge the fields of engineering, ecology, landscape architecture, and urban planning. A conceptual implementation of these strategies is demonstrated through a design for a small constructed wetland treatment system in San Francisco, California. The proposed decentralized system described in this article consists of a detention basin, vegetated and open free water surface wetlands, and ultraviolet disinfection. In wet weather, the system would detain and treat combined sewer discharges (CSD), and in dry weather it would treat residential greywater for toilet flushing and irrigation in a nearby neighborhood. It is designed to adapt over time to changing climatic conditions and treatment demands. Importantly, this proposal demonstrates how constructed wetland engineers can incorporate multiple benefits into their systems, offering a vision of how wastewater infrastructure can be an attractive community, educational, recreational, and habitat amenity through the integration of engineering, ecology, and landscape design.

  12. Risks associated with the environmental release of pharmaceuticals on the U.S. Food and Drug Administration "flush list".

    PubMed

    Khan, Usman; Bloom, Raanan A; Nicell, James A; Laurenson, James P

    2017-12-31

    A select few prescription drugs can be especially harmful and, in some cases, fatal with just one dose when not used as prescribed. Therefore, the U. S. Food and Drug Administration (FDA) recommends that expired, unwanted, or otherwise unused portions of most of these drugs be disposed of quickly through a take-back program. If such an option is not readily available, FDA recommends that they be flushed down the sink or toilet. The goal of the current investigation was to evaluate the ecological and human-health risks associated with the environmental release of the 15 active pharmaceutical ingredients (APIs) currently on the FDA "flush list". The evaluation suggests that even when highly conservative assumptions are used-including that the entire API mass supplied for clinical use is flushed, all relevant sources in addition to clinical use of the API are considered, and no metabolic loss, environmental degradation, or dilution of wastewater effluents are used in estimating environmental concentrations-most of these APIs present a negligible eco-toxicological risk, both as individual compounds and as a mixture. For a few of these APIs, additional eco-toxicological data will need to be developed. Using similar conservative assumptions for human-health risks, all 15 APIs present negligible risk through ingestion of water and fish. Published by Elsevier B.V.

  13. Watershed monitoring and modelling and USA regulatory compliance.

    PubMed

    Turner, B G; Boner, M C

    2004-01-01

    The aim of the Columbus program was to implement a comprehensive watershed monitoring-network including water chemistry, aquatic biology and alternative sensors to establish water environment health and methods for determining future restoration progress and early warning for protection of drinking water supplies. The program was implemented to comply with USA regulatory requirements including Total Maximum Daily Load (TMDL) rules of the Clean Water Act (CWA) and Source Water Assessment and Protection (SWAP) rules under the Safe Drinking Water Act (SDWA). The USEPA Office of Research and Development and the Water Environment Research Foundation provided quality assurance oversight. The results obtained demonstrated that significant wet weather data is necessary to establish relationships between land use, water chemistry, aquatic biology and sensor data. These measurements and relationships formed the basis for calibrating the US EPA BASINS Model, prioritizing watershed health and determination of compliance with water quality standards. Conclusions specify priorities of cost-effective drainage system controls that attenuate stormwater flows and capture flushed pollutants. A network of permanent long-term real-time monitoring using combination of continuous sensor measurements, water column sampling and aquatic biology surveys and a regional organization is prescribed to protect drinking water supplies and measure progress towards water quality targets.

  14. Electrochemical immunoassay on a microfluidic device with sequential injection and flushing functions.

    PubMed

    Nashida, Norihiro; Satoh, Wataru; Fukuda, Junji; Suzuki, Hiroaki

    2007-06-15

    An integrated microfluidic device with injecting, flushing, and sensing functions was realized using valves that operate based on direct electrowetting. The device consisted of two substrates: a glass substrate with driving and sensing electrodes and a poly(dimethylsiloxane) (PDMS) substrate. Microfluidic transport was achieved using the spontaneous movement of solutions in hydrophilic flow channels formed with a dry-film photoresist layer. The injection and flushing of solutions were controlled by gold working electrodes, which functioned as valves. The valves were formed either in the channels or in a through-hole in the glass substrate. To demonstrate the system's applicability to an immunoassay, the detection of immobilized antigens was performed as a partial simulation of a sandwich immunoassay. Human alpha-fetoprotein (AFP) or an anti-human AFP antibody was immobilized on a platinum working electrode in the chamber using a plasma-polymerized film (PPF). By applying a potential to the injection valves, necessary solutions were injected one by one through the channels into a reaction chamber at the center of the chip and incubated for reasonable periods of time. The solutions were then flushed through the flushing valve and absorbed in a filter paper placed under the device. After incubation with the corresponding antibodies labeled with glucose oxidase (GOD), electrochemical detection was conducted. In both cases, the obtained current depended on the amount of immobilized antigen. The calibration curves were sigmoidal, and the detection limit was 0.1 ng. The developed microfluidic system could potentially be a fundamental component for a micro immunoassay of the next generation.

  15. ENHANCED SOURCE REMOVAL USING IN-SITU CHEMICAL FLUSHING

    EPA Science Inventory

    Dense non-aqueous phase liquids (DNAPL) have been identified as a major impediment to the cleanup of many contaminated sites. Conventional ground water remediation methods such as pump-and-treat have proven ineffective at these sites. As a result, alternative remediation approach...

  16. 30 CFR 71.402 - Minimum requirements for bathing facilities, change rooms, and sanitary flush toilet facilities.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...) Showers shall be provided with both hot and cold water. (ii) At least one shower head shall be provided... urinal. (iv) An adequate supply of toilet paper shall be provided with each toilet. (v) Adequate...

  17. 30 CFR 71.402 - Minimum requirements for bathing facilities, change rooms, and sanitary flush toilet facilities.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...) Showers shall be provided with both hot and cold water. (ii) At least one shower head shall be provided... urinal. (iv) An adequate supply of toilet paper shall be provided with each toilet. (v) Adequate...

  18. 30 CFR 71.402 - Minimum requirements for bathing facilities, change rooms, and sanitary flush toilet facilities.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ...) Showers shall be provided with both hot and cold water. (ii) At least one shower head shall be provided... urinal. (iv) An adequate supply of toilet paper shall be provided with each toilet. (v) Adequate...

  19. 30 CFR 71.402 - Minimum requirements for bathing facilities, change rooms, and sanitary flush toilet facilities.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ...) Showers shall be provided with both hot and cold water. (ii) At least one shower head shall be provided... urinal. (iv) An adequate supply of toilet paper shall be provided with each toilet. (v) Adequate...

  20. 30 CFR 71.402 - Minimum requirements for bathing facilities, change rooms, and sanitary flush toilet facilities.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...) Showers shall be provided with both hot and cold water. (ii) At least one shower head shall be provided... urinal. (iv) An adequate supply of toilet paper shall be provided with each toilet. (v) Adequate...

  1. Gage for measuring coastal erosion and sedimentation

    NASA Technical Reports Server (NTRS)

    Carpini, T. D.; Moughon, W. C.

    1970-01-01

    Underwater sand height gage, which measures heights up to 12 inches, is comprised of two standard flush-diaphragm pressure transducers. Gage is very sensitive to buried water heights and is useful as a research tool in study of wet earth and landslide phenomena.

  2. Modeling urban storm rainfall runoff from diverse underlying surfaces and application for control design in Beijing.

    PubMed

    Ouyang, Wei; Guo, Bobo; Hao, Fanghua; Huang, Haobo; Li, Junqi; Gong, Yongwei

    2012-12-30

    Managing storm rainfall runoff is paramount in semi-arid regions with urban development. In Beijing, pollution prevention in urban storm runoff and storm water utilization has been identified as the primary strategy for urban water management. In this paper, we sampled runoff during storm rainfall events and analyzed the concentration of chemical oxygen demand (COD), total suspended solids (TSS) and total phosphorus (TP) in the runoff. Furthermore, the first flush effect of storm rainfall from diverse underlying surfaces was also analyzed. With the Storm Water Management Model (SWMM), the different impervious rates of underlying surfaces during the storm runoff process were expressed. The removal rates of three typical pollutants and their interactions with precipitation and underlying surfaces were identified. From these rates, the scenarios regarding the urban storm runoff pollution loading from different designs of underlying previous rates were assessed with the SWMM. First flush effect analysis showed that the first 20% of the storm runoff should be discarded, which can help in utilizing the storm water resource. The results of this study suggest that the SWMM can express in detail the storm water pollution patterns from diverse underlying surfaces in Beijing, which significantly affected water quality. The scenario analysis demonstrated that impervious rate adjustment has the potential to reduce runoff peak and decrease pollution loading. Copyright © 2012 Elsevier Ltd. All rights reserved.

  3. The Phytotoxicity of Designated Pollutants

    DTIC Science & Technology

    1981-12-01

    necrotic injury on tomato and barley leaves .* . . .* . . . . . . . .e .o . . . . o . . . . .o . 74 A4 Pictorial key for necrotic injury on lettuce and...water flushed with water. ................ 58 43 Growth of barley seedlings from soil previously treated with jet fuel .................. 60 44 Growth of...Variety or Cultivar Alfalfa Medicago sativa L. Cu F101, Bonanza Barley Hordeum vulgare L. CM67 Bean Phaseolus vulgaris L. Pinto U.I. III Carrot Daucus

  4. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dam, William; Gil, Dr. April; Johnson, Raymond H.

    The US Department of Energy Office of Legacy Management (LM) is responsible for maintaining protective public health and environmental conditions at former uranium mill tailings sites nationwide via long-term stewardship. One of these sites, a former uranium mill near Riverton, Wyoming, is within the boundary of the Wind River Indian Reservation and operated from 1958 to 1963. Tailings and contaminated material associated with mill operations were removed and transported to an offsite disposal cell in 1989. The remedial action was completed under Title I of the Uranium Mill Tailings Radiation Control Act of 1978. Milling operations, which included an unlinedmore » tailings impoundment and an unlined evaporation pond, contaminated the shallow groundwater, resulting in a downgradient groundwater plume that discharges to the Little Wind River. A natural flushing compliance strategy was implemented in 1998. This strategy allows contaminants of concern to naturally flush from the groundwater, provided that contaminants flush below US Environmental Protection Agency maximum concentration limits within 100 years. As part of the compliance strategy, LM has implemented a groundwater monitoring program along with institutional controls that include the installation of an alternate water supply, continued sampling of private wells, and restrictions on well drilling and gravel pit construction. LM works closely with local stakeholders and community members to ensure that these institutional controls are in place and maintained. The Riverton site provides an interesting case study where contaminant remobilization due to river flooding prompted a reevaluation of the conceptual site model to verify if the current compliance strategy would remain protective of human health and the environment. Concentrations of groundwater contaminants, which include sulfate, molybdenum, and uranium, were transiently elevated following flooding of the Little Wind River in 2010 and 2016. These flood events provided the impetus to investigate other aspects of the hydrologic system, including the unsaturated zone, naturally reduced (sulfidic) zones, and evaporite deposits. New site conceptual models, field and laboratory studies, and numerical models are being developed to explain how biogeochemical sediment–water interactions contribute to plume persistence and flood-related increases in groundwater concentrations. Updated human health and ecological risk assessments are progressing to evaluate the risk to human health and the environment based on current site conditions. Groundwater concentrations may remain above US Environmental Protection Agency maximum concentration limits beyond the 100-year natural flushing regulatory time frame. LM in its capacity as a long-term steward continues to monitor the site to ensure protectiveness is maintained and to determine the feasibility of alternative compliance and remediation strategies.« less

  5. Hormonal control of second flushing in Douglas-fir shoots.

    Treesearch

    Morris Cline; Mark Yoders; Dipti Desai; Constance Harrington; William Carlson

    2006-01-01

    Spring-flushing, over-wintered buds of Douglas-fir (Pseudotsuga menziesii (Mirb.) Franco) produce new buds that may follow various developmental pathways. These include second flushing in early summer or dormancy before flushing during the following spring. Second flushing usually entails an initial release of apical dominance as some of the...

  6. A combined process coupling phytoremediation and in situ flushing for removal of arsenic in contaminated soil.

    PubMed

    Yan, Xiulan; Liu, Qiuxin; Wang, Jianyi; Liao, Xiaoyong

    2017-07-01

    Phytoremediation and soil washing are both potentially useful for remediating arsenic (As)-contaminated soils. We evaluated the effectiveness of a combined process coupling phytoremediation and in situ soil flushing for removal of As in contaminated soil through a pilot study. The results showed that growing Pteris vittata L. (P.v.) accompanied by soil flushing of phosphate (P.v./Flushing treatment) could significantly decrease the total As concentration of soil over a 37day flushing period compared with the single flushing (Flushing treatment). The P.v./Flushing treatment removed 54.04% of soil As from contaminated soil compared to 47.16% in Flushing treatment, suggesting that the growth of P. vittata was beneficial for promoting the removal efficiency. We analyzed the As fractionation in soil and As concentration in soil solution to reveal the mechanism behind this combined process. Results showed that comparing with the control treatment, the percent of labile arsenate fraction significantly increased by 17% under P.v./Flushing treatment. As concentration in soil solution remained a high lever during the middle and later periods (51.26-56.22mg/L), which was significantly higher than the Flushing treatment. Although soil flushing of phosphate for more than a month, P. vittata still had good accumulation and transfer capacity of As of the soil. The results of the research revealed that combination of phytoremediation and in situ soil flushing is available to remediate As-contaminated soils. Copyright © 2016. Published by Elsevier B.V.

  7. Analysis of boron dilution in a four-loop PWR

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sun, J.G.; Sha, W.T.

    1995-03-01

    Thermal mixing and boron dilution in a pressurized water reactor were analyzed with COMMIX codes. The reactor system was the four-loop Zion reactor. Two boron dilution scenarios were analyzed. In the first scenario, the plant is in cold shutdown and the reactor coolant system has just been filled after maintenance on the steam generators. To flush the air out of the steam generator tubes, a reactor coolant pump (RCP) is started, with the water in the pump suction line devoid of boron and at the same temperature as the coolant in the system. In the second scenario, the plant ismore » at hot standby and the reactor coolant system has been heated to operating temperature after a long outage. It is assumed that an RCP is started, with the pump suction line filled with cold unborated water, forcing a slug of diluted coolant down the downcomer and subsequently through the reactor core. The subsequent transient thermal mixing and boron dilution that would occur in the reactor system is simulated for these two scenarios. The reactivity insertion rate and the total reactivity are evaluated and a sensitivity study is performed to assess the accuracy of the numerical modeling of the geometry of the reactor coolant system.« less

  8. Response of respiration and nutrient availability to drying and rewetting in soil from a semi-arid woodland depends on vegetation patch and a recent wild fire

    NASA Astrophysics Data System (ADS)

    Sun, Q.; Meyer, W. S.; Koerber, G.; Marschner, P.

    2015-06-01

    Semi-arid woodlands, which are characterised by patchy vegetation interspersed with bare, open areas, are frequently exposed to wild fire. During summer, long dry periods are occasionally interrupted by rainfall events. It is well-known that rewetting of dry soil induces a flush of respiration. However, the magnitude of the flush may differ between vegetation patches and open areas because of different organic matter content which could be further modulated by wild fire. Soils were collected from under trees, under shrubs or in open areas in unburnt and burnt sandy Mallee woodland, where part of the woodland experienced a wild fire which destroyed or damaged most of the aboveground plant parts four months before sampling. In an incubation experiment, the soils were exposed to two moisture treatments: constantly moist (CM) and drying and rewetting (DRW). In CM, soils were incubated at 80% of maximum water holding capacity for 19 days; In DRW, soils were dried for four days, kept dry for another five days, then rewet to 80% WHC and maintained at this water content until day 19. Soil respiration decreased during drying and was very low in the dry period; rewetting induced a respiration flush. Compared to soil under shrubs and in open areas, cumulative respiration per g soil in CM and DRW was greater under trees, but lower when expressed per g TOC. Organic matter content, available P, and microbial biomass C, but not available N were greater under trees than in open areas. Wild fire decreased the flush of respiration per g TOC in the open areas and under shrubs, and reduced TOC and MBC concentrations only under trees, but had little effect on available N and P concentrations. We conclude that of the impact wild fire and DRW events on nutrient cycling differ among vegetation patches of a native semiarid woodland which is related to organic matter amount and availability.

  9. Field Application of Modified In Situ Soil Flushing in Combination with Air Sparging at a Military Site Polluted by Diesel and Gasoline in Korea

    PubMed Central

    Lee, Hwan; Lee, Yoonjin; Kim, Jaeyoung; Kim, Choltae

    2014-01-01

    In this study the full-scale operation of soil flushing with air sparging to improve the removal efficiency of petroleum at depths of less than 7 m at a military site in Korea was evaluated. The target area was polluted by multiple gasoline and diesel fuel sources. The soil was composed of heterogeneous layers of granules, sand, silt and clay. The operation factors were systemically assessed using a column test and a pilot study before running the full-scale process at the site. The discharged TPH and BTEX (benzene, toluene, ethylbenzene, and xylenes) concentrations in the water were highest at 20 min and at a rate of 350 L/min, which was selected as the volume of air for the full-scale operation in the pilot air sparging test. The surfactant-aid condition was 1.4 times more efficient than the non-surfactant condition in the serial operations of modified soil flushing followed by air sparging. The hydraulic conductivity (3.13 × 10−3 cm/s) increased 4.7 times after the serial operation of both processes relative to the existing condition (6.61 × 10−4 cm/s). The removal efficiencies of TPH were 52.8%, 57.4%, and 61.8% for the soil layers at 6 to 7, 7 to 8 and 8 to 9 m, respectively. Therefore, the TPH removal was improved at depth of less than 7 m by using this modified remediation system. The removal efficiencies for the areas with TPH and BTEX concentrations of more than 500 and 80 mg/kg, were 55.5% and 92.9%, respectively, at a pore volume of 2.9. The total TPH and BTEX mass removed during the full-scale operation was 5109 and 752 kg, respectively. PMID:25166919

  10. Relating salt marsh pore water geochemistry patterns to vegetation zones and hydrologic influences

    NASA Astrophysics Data System (ADS)

    Moffett, Kevan B.; Gorelick, Steven M.

    2016-03-01

    Physical, chemical, and biological factors influence vegetation zonation in salt marshes and other wetlands, but connections among these factors could be better understood. If salt marsh vegetation and marsh pore water geochemistry coorganize, e.g., via continuous plant water uptake and persistently unsaturated sediments controlling vegetation zone-specific pore water geochemistry, this could complement known physical mechanisms of marsh self-organization. A high-resolution survey of pore water geochemistry was conducted among five salt marsh vegetation zones at the same intertidal elevation. Sampling transects were arrayed both parallel and perpendicular to tidal channels. Pore water geochemistry patterns were both horizontally differentiated, corresponding to vegetation zonation, and vertically differentiated, relating to root influences. The geochemical patterns across the site were less broadly related to marsh hydrology than to vegetation zonation. Mechanisms contributing to geochemical differentiation included: root-induced oxidation and nutrient (P) depletion, surface and creek-bank sediment flushing by rainfall or tides, evapotranspiration creating aerated pore space for partial sediment flushing in some areas while persistently saturated conditions hindered pore water renewal in others, and evapoconcentration of pore water solutes overall. The concentrated pore waters draining to the tidal creeks accounted for 41% of ebb tide solutes (median of 14 elements), including being a potentially toxic source of Ni but a slight sink for Zn, at least during the short, winter study period in southern San Francisco Bay. Heterogeneous vegetation effects on pore water geochemistry are not only significant locally within the marsh but may broadly influence marsh-estuary solute exchange and ecology.

  11. Effects of Water Bottle Materials and Filtration on Bisphenol A Content in Laboratory Animal Drinking Water.

    PubMed

    Honeycutt, Jennifer A; Nguyen, Jenny Q T; Kentner, Amanda C; Brenhouse, Heather C

    2017-05-01

    Bisphenol A (BPA) is widely used in the polycarbonate plastics and epoxy resins that are found in laboratory animal husbandry materials including cages and water bottles. Concerns about BPA exposure in humans has led to investigations that suggest physiologic health risks including disruptions to the endocrine system and CNS. However, the extent of exposure of laboratory animals to BPA in drinking water is unclear. In the first study, we compared the amount of BPA contamination in water stored in plastic bottles used in research settings with that in glass bottles. The amount of BPA that leached into water was measured across several time points ranging from 24 to 96 h by using a BPA ELISA assay. The results showed that considerable amounts of BPA (approximately 0.15 μg/L) leached from polycarbonate bottles within the first 24 h of storage. In the second study, BPA levels were measured directly from water taken from filtered compared with unfiltered taps. We observed significantly higher BPA levels in water from unfiltered taps (approximately 0.40 μg/L) compared with taps with filtration systems (approximately 0.04 μg/L). Taken together, our findings indicate that the use of different types of water bottles and water sources, combined with the use of different laboratory products (food, caging systems) between laboratories, likely contribute to decreased rigor and reproducibility in research. We suggest that researchers consider reporting the types of water bottles used and that animal care facilities educate staff regarding the importance of flushing nonfiltered water taps when filling animal water bottles.

  12. Effects of Water Bottle Materials and Filtration on Bisphenol A Content in Laboratory Animal Drinking Water

    PubMed Central

    Honeycutt, Jennifer A; Nguyen, Jenny Q T; Kentner, Amanda C; Brenhouse, Heather C

    2017-01-01

    Bisphenol A (BPA) is widely used in the polycarbonate plastics and epoxy resins that are found in laboratory animal husbandry materials including cages and water bottles. Concerns about BPA exposure in humans has led to investigations that suggest physiologic health risks including disruptions to the endocrine system and CNS. However, the extent of exposure of laboratory animals to BPA in drinking water is unclear. In the first study, we compared the amount of BPA contamination in water stored in plastic bottles used in research settings with that in glass bottles. The amount of BPA that leached into water was measured across several time points ranging from 24 to 96 h by using a BPA ELISA assay. The results showed that considerable amounts of BPA (approximately 0.15 μg/L) leached from polycarbonate bottles within the first 24 h of storage. In the second study, BPA levels were measured directly from water taken from filtered compared with unfiltered taps. We observed significantly higher BPA levels in water from unfiltered taps (approximately 0.40 μg/L) compared with taps with filtration systems (approximately 0.04 μg/L). Taken together, our findings indicate that the use of different types of water bottles and water sources, combined with the use of different laboratory products (food, caging systems) between laboratories, likely contribute to decreased rigor and reproducibility in research. We suggest that researchers consider reporting the types of water bottles used and that animal care facilities educate staff regarding the importance of flushing nonfiltered water taps when filling animal water bottles. PMID:28535862

  13. The influence of small-scale interlayer heterogeneity on DDT removal efficiency for flushing technology

    NASA Astrophysics Data System (ADS)

    Wang, Xingwei; Chen, Jiajun

    2017-06-01

    With an aim to investigate the influence of small-scale interlayer heterogeneity on DDT removal efficiency, batch test including surfactant-stabilized foam flushing and solution flushing were carried out. Two man-made heterogeneous patterns consisting of coarse and fine quartz sand were designed to reveal the influencing mechanism. Moreover, the removal mechanism and the corresponding contribution by foam flushing were quantitatively studied. Compared with surfactant solution flushing, the DDT removal efficiency by surfactant-stabilized foam flushing increased by 9.47% and 11.28% under heterogeneous patterns 1 and 2, respectively. The DDT removal contributions of improving sweep efficiency for heterogeneous patterns 1 and 2 by foam flushing were 40.82% and 45.98%, and the contribution of dissolving capacity were 59.18% and 54.02%, respectively. The dissolving capacity of DDT played a major role in DDT removal efficiency by foam flushing under laboratory conditions. And the DDT removal contribution of significant improving sweep efficiency was higher than that of removal decline caused by weak solubilizing ability of foam film compared with solution flushing. The obtained results indicated that the difference of DDT removal efficiency by foam flushing was decreased under two different heterogeneous patterns with the increase of the contribution of improving foam flushing sweep efficiency. It suggested that foam flushing can reduce the disturbance from interlayer heterogeneity in remediating DDT contaminated heterogeneous medium.

  14. Overview of a simple model describing variation of dissolved organic carbon in an upland catchment

    USGS Publications Warehouse

    Boyer, Elizabeth W.; Hornberger, George M.; Bencala, Kenneth E.; McKnight, Diane M.

    1996-01-01

    Hydrological mechanisms controlling the variation of dissolved organic carbon (DOC) were investigated in the Deer Creek catchment located near Montezuma, CO. Patterns of DOC in streamflow suggested that increased flows through the upper soil horizon during snowmelt are responsible for flushing this DOC-enriched interstitial water to the streams. We examined possible hydrological mechanisms to explain the observed variability of DOC in Deer Creek by first simulating the hydrological response of the catchment using TOPMODEL and then routing the predicted flows through a simple model that accounted for temporal changes in DOC. Conceptually the DOC model can be taken to represent a terrestrial (soil) reservoir in which DOC builds up during low flow periods and is flushed out when infiltrating meltwaters cause the water table to rise into this “reservoir”. Concentrations of DOC measured in the upper soil and in streamflow were compared to model simulations. The simulated DOC response provides a reasonable reproduction of the observed dynamics of DOC in the stream at Deer Creek.

  15. An advanced modelling tool for simulating complex river systems.

    PubMed

    Trancoso, Ana Rosa; Braunschweig, Frank; Chambel Leitão, Pedro; Obermann, Matthias; Neves, Ramiro

    2009-04-01

    The present paper describes MOHID River Network (MRN), a 1D hydrodynamic model for river networks as part of MOHID Water Modelling System, which is a modular system for the simulation of water bodies (hydrodynamics and water constituents). MRN is capable of simulating water quality in the aquatic and benthic phase and its development was especially focused on the reproduction of processes occurring in temporary river networks (flush events, pools formation, and transmission losses). Further, unlike many other models, it allows the quantification of settled materials at the channel bed also over periods when the river falls dry. These features are very important to secure mass conservation in highly varying flows of temporary rivers. The water quality models existing in MOHID are base on well-known ecological models, such as WASP and ERSEM, the latter allowing explicit parameterization of C, N, P, Si, and O cycles. MRN can be coupled to the basin model, MOHID Land, with computes runoff and porous media transport, allowing for the dynamic exchange of water and materials between the river and surroundings, or it can be used as a standalone model, receiving discharges at any specified nodes (ASCII files of time series with arbitrary time step). These features account for spatial gradients in precipitation which can be significant in Mediterranean-like basins. An interface has been already developed for SWAT basin model.

  16. Biologically Pre-Treated Habitation Waste Water as a Sustainable Green Urine Pre-Treat Solution

    NASA Technical Reports Server (NTRS)

    Jackson, W. Andrew; Thompson, Bret; Sevanthi, Ritesh; Morse, Audra; Meyer, Caitlin; Callahan, Michael

    2017-01-01

    The ability to recover water from urine and flush water is a critical process to allow long term sustainable human habitation in space or bases on the moon or mars. Organic N present as urea or similar compounds can hydrolyze producing free ammonia. This reaction results in an increase in the pH converting ammonium to ammonia which is volatile and not removed by distillation. The increase in pH will also cause precipitation reactions to occur. In order to prevent this, urine on ISS is combined with a pretreat solution. While use of a pretreatment solution has been successful, there are numerous draw backs including: storage and use of highly hazardous solutions, limitations on water recovery (less than 85%), and production of brine with pore dewatering characteristics. We evaluated the use of biologically treated habitation wastewaters (ISS and early planetary base) to replace the current pretreat solution. We evaluated both amended and un-amended bioreactor effluent. For the amended effluent, we evaluated "green" pretreat chemicals including citric acid and citric acid amended with benzoic acid. We used a mock urine/air separator modeled after the urine collection assembly on ISS. The urine/air separator was challenged continually for >6 months. Depending on the test point, the separator was challenged daily with donated urine and flushed with amended or un-amended reactor effluent. We monitored the pH of the urine, flush solution and residual pH in the urine/air separator after each urine event. We also evaluated solids production and biological growth. Our results support the use of both un-amended and amended bioreactor effluent to maintain the operability of the urine /air separator. The ability to use bioreactor effluent could decrease consumable cost, reduce hazards associated with current pre-treat chemicals, allow other membrane based desalination processes to be utilized, and improve brine characteristics.

  17. The Role of Environmental Forcing in Controlling Water Retention Gyres in Subsystems of Narragansett Bay

    NASA Astrophysics Data System (ADS)

    Balt, C.; Kincaid, C. R.; Ullman, D. S.

    2010-12-01

    Greenwich Bay and the Providence River represent two subsystems of the Narragansett Bay (RI) estuary with chronic water quality problems. Both underway and moored Acoustic Doppler Current Profiler (ADCP) observations have shown the presence of large-scale, subtidal gyres within these subsystems. Prior numerical models of Narragansett Bay, developed using the Regional Ocean Modeling System (ROMS), indicate that prevailing summer sea breeze conditions are favorable to the evolution of stable circulation gyres, which increase retention times within each subsystem. Fluid dynamics laboratory models of the Providence River, conducted in the Geophysical Fluid Dynamics Laboratory of the Research School of Earth Sciences (Australian National University), reproduce gyres that match first order features of the ADCP data. These laboratory models also reveal details of small-scale eddies along the edges of the retention gyre. We report results from spatially and temporally detailed current meter deployments (using SeaHorse Tilt Current Meters) in both subsystems, which reveal details on the growth and decay of gyres under various spring-summer forcing conditions. In particular, current meters were deployed during the severe flooding events in the Narragansett Bay watershed during March, 2010. A combination of current meter data and high-resolution ROMS modeling is used to show how gyres effectively limit subtidal exchange from the Providence River and Greenwich Bay and to understand the forcing conditions that favor efficient flushing. The residence times of stable gyres within these regions can be an order of magnitude larger than values predicted by fraction of water methods. ROMS modeling is employed to characterize gyre energy, stability, and flushing rates for a wide range of seasonal, wind and runoff scenarios.

  18. Mind the bubbles: achieving stable measurements of maximum hydraulic conductivity through woody plant samples

    PubMed Central

    Espino, Susana; Schenk, H. Jochen

    2011-01-01

    The maximum specific hydraulic conductivity (kmax) of a plant sample is a measure of the ability of a plants’ vascular system to transport water and dissolved nutrients under optimum conditions. Precise measurements of kmax are needed in comparative studies of hydraulic conductivity, as well as for measuring the formation and repair of xylem embolisms. Unstable measurements of kmax are a common problem when measuring woody plant samples and it is commonly observed that kmax declines from initially high values, especially when positive water pressure is used to flush out embolisms. This study was designed to test five hypotheses that could potentially explain declines in kmax under positive pressure: (i) non-steady-state flow; (ii) swelling of pectin hydrogels in inter-vessel pit membranes; (iii) nucleation and coalescence of bubbles at constrictions in the xylem; (iv) physiological wounding responses; and (v) passive wounding responses, such as clogging of the xylem by debris. Prehydrated woody stems from Laurus nobilis (Lauraceae) and Encelia farinosa (Asteraceae) collected from plants grown in the Fullerton Arboretum in Southern California, were used to test these hypotheses using a xylem embolism meter (XYL'EM). Treatments included simultaneous measurements of stem inflow and outflow, enzyme inhibitors, stem-debarking, low water temperatures, different water degassing techniques, and varied concentrations of calcium, potassium, magnesium, and copper salts in aqueous measurement solutions. Stable measurements of kmax were observed at concentrations of calcium, potassium, and magnesium salts high enough to suppress bubble coalescence, as well as with deionized water that was degassed using a membrane contactor under strong vacuum. Bubble formation and coalescence under positive pressure in the xylem therefore appear to be the main cause for declining kmax values. Our findings suggest that degassing of water is essential for achieving stable and precise measurements of kmax through woody plant samples. For complete rehydration of woody samples, incubation in water under vacuum for 24 h is suggested as a reliable technique that avoids bubble problems associated with flushing under high positive pressure. PMID:21147811

  19. Processes controlling the episodic streamwater transport of atrazine and other agrichemicals in an agricultural watershed

    USGS Publications Warehouse

    Hyer, Kenneth; Hornberger, George M.; Herman, Janet S.

    2001-01-01

    Episodic streamwater transport of atrazine (a common agricultural herbicide) and nutrients has been observed throughout agricultural watersheds in the United States and poses a serious threat to the quality of its water resources. Catchment-scale atrazine and nutrient transport processes after agricultural application are still poorly understood, and predicting episodic streamwater composition remains an elusive goal. We instrumented a 1.2-km2 agricultural catchment near Harrisonburg, Virginia, and examined streamwater, overland flow, soil water, groundwater, and rainfall during the summer of 1998. Storm chemographs demonstrated different patterns for constituents derived primarily from weathering (silica and calcium), compared to constituents derived primarily from early spring land applications (nitrate, atrazine, DOC, potassium, chloride, and sulfate). During storms, the concentrations of silica and calcium decreased, the atrazine response was variable, and the concentrations of nitrate, DOC, potassium, chloride, and sulfate increased; the elevated nitrate signal lagged several hours behind the other elevated constituents. Graphical and statistical analyses indicated a relatively stable spring-fed baseflow was modified by a mixture of overland flow and soil water. A rapid, short-duration overland-flow pulse dominated the streamflow early in the event and contributed most of the potassium, DOC, chloride, suspended sediment, and atrazine. A longer-duration soil–water pulse dominated the streamflow later in the event and contributed the nitrate as well as additional potassium, DOC, sulfate, and atrazine. The contributions to the episodic streamflow were quantified using a flushing model in which overland-flow and soil–water concentrations decreased exponentially with time during an episode. Flushing time constants for the overland-flow and soil–water reservoirs were calculated on a storm-by-storm basis using separate tracers for each time-variable reservoir. Initial component concentrations were estimated through regression analyses. Mass-balance calculations were used for flow separations and to predict the observed streamwater composition. Model forecasts indicated that reduced fertilizer and pesticide application (rather than elimination of overland-flow or soil–water contributions) was necessary to improve the episodic streamwater composition. This study provides important additional understanding of the catchment-scale processes by which land-applied pesticides and nutrients can move through agricultural systems.

  20. Hypothesis of demodicidosis rosacea flushing etiopathogenesis.

    PubMed

    Robledo, Mary Ann; Orduz, Mariana

    2015-04-01

    Most of the patients with erythematotelangiectatic rosacea are characterized by flushing, oedema and telangiectasia. The etiopathogenesis of the flushing in rosacea patients is unknown. Clinically the flushing in rosacea is similar to the "Asian flushing syndrome". Most Asians have an overactive alcohol dehydrogenase (ADH) that tends to break down alcohol into acetaldehyde faster. People with "Asians flushing syndrome" have a genetic disorder with the Aldehyde Dehydrogenase 2(∗)2 (ALDH2(∗)2) allele. This is the reason why they do not metabolize very well the acetaldehyde that comes from the alcohol, which means that acetaldehyde takes much longer to clear from their blood. ALDH2 enzyme is primarily responsible for oxidation of acetaldehyde derived from ethanol metabolism, as well as oxidation of various other endogenous and exogenous aldehydes. Acetaldehyde produces the vasodilatation in the "Asian flushing syndrome". The antibodies against the GroEl chaperonin protein, a 62-kDa heat shock protein were found in the Bacillus oleronius isolated from Demodex mites, in rosacea patients. The GroEl chaperonin protein is a protein that plays a key role in normal folding of ALDH2. If the GroEl chaperonin antibodies found in patients with rosacea, cross react with the human GroEl chaperonin protein, they will not fold normally the ALDH2, and then the enzyme will not metabolize the acetaldehyde. Many of the patients with rosacea have a concomitant infection with Helicobacter pylori in their stomach. The H.pylori produces high amounts of acetaldehyde, which comes from their metabolism of ethanol or carbohydrates. As a result, high amounts of acetaldehyde will circulate for longer time in the blood, until the liver CYP2E1(p450) enzyme system finally metabilizes the acetaldehyde, during that period of time the patients will experience a flushing as well as the people with the "Asian flushing syndrome" suffer when they drink ethanol. To prove the hypothesis it is necessary to find the cross reaction between the GroEl chaperonin antibodies against the B.oleronius and human GroEl chaperonin. Four groups of patients will be studied with or without the GroEl chaperonin antibodies, and H.Pylori. The production of acetaldehyde will be tested by the ethanol-derived microbial production method. If the hypothesis proves to be true, the treatment of Demodex mites and the H. pylori could improve the flushing in the rosacea patients and it will prevent the angiogenesis (telangiectasia), and the association of the gastric injury and carcinogenesis in those patients. Copyright © 2015 Elsevier Ltd. All rights reserved.

  1. Application of the FADS system on the Re-entry Module

    NASA Astrophysics Data System (ADS)

    Zhen, Huang

    2016-07-01

    The aerodynamic model for Flush Air Data Sensing System (FADS) is built based on the surface pressure distribution obtained through the pressure orifices laid on specific positions of the surface,and the flight parameters,such as angle of attack,angle of side-slip,Mach number,free-stream static pressure and dynamic pressure are inferred from the aerodynamic model.The flush air data sensing system (FADS) has been used on several flight tests of aircraft and re-entry vehicle,such as,X-15,space shuttle,F-14,X-33,X-43A and so on. This paper discusses the application of the FADS on the re-entry module with blunt body to obtain high-precision aerodynamic parameters.First of all,a basic theory and operating principle of the FADS is shown.Then,the applications of the FADS on typical aircrafts and re-entry vehicles are described.Thirdly,the application mode on the re-entry module with blunt body is discussed in detail,including aerodynamic simulation,pressure distribution,trajectory reconstruction and the hardware shoule be used,such as flush air data sensing system(FADS),inertial navigation system (INS),data acquisition system,data storage system.Finally,ablunt module re-entry flight test from low earth orbit (LEO) is planned to obtain aerodynamic parameters and amend the aerodynamic model with this FADS system data.The results show that FADS system can be applied widely in re-entry module with blunt bodies.

  2. Breckinridge Project, initial effort

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    1982-01-01

    Report V, Volume 4 provides descriptions, data, and drawings pertaining to Instrument and Plant Air Systems (Plant 36), Telecommunication Systems (Plant 37), Inert Gas Systems (Plant 38), Purge and Flush Oil Systems (Plant 39), Site Development and Roads (Plant 40), Buildings (Plant 41), Solid Waste Management (Plant 42), and Landfill (Plant 44). Instrument and Plant Air Systems (Plant 36) includes all equipment and piping necessary to supply instrument and utility air to the process plants and offsite facilities. Telecommunication Systems (Plant 37) includes the equipment and wiring for: communication throughout the facility; communication between plant data processing systems and offsitemore » computing facilities; and communication with transportation carriers. Inert Gas Systems (Plant 38) provides high purity and low purity nitrogen streams for plant startup and normal operation. Purge and Flush Oil Systems (Plant 39) provides purge and flush oils to various plants. Site Development and Roads (Plant 40) provides site leveling, the addition of roads, fencing, and drainage, and the placement of fills, pilings, footings, and foundations for plants. Buildings (Plant 41) provides buildings for equipment and for personnel, including utilities, lighting, sanitary facilities, heating, air conditioning, and ventilation. Solid Waste Management (Plant 42) identifies, characterizes, segregates, and transports the various types of solid wastes to either Landfill (Plant 44) or outside disposal sites. Landfill (Plant 44) provides disposal of both nonhazardous and hazardous solid wastes. Information is included (as applicable) for each of the eight plants described.« less

  3. Evaluation of Military Field-Water Quality. Volume 7. Performance Evaluation of the 600-GPH Reverse Osmosis Water Purification Unit (ROWPU): reverse Osmosis (RO) Components

    DTIC Science & Technology

    1986-02-01

    Data-for ASsessingHealthRISKS In Potential Theaters ~ of Operation forU,5. Mil-itary._orces. Jf-jr cLAss t:cAToN 9; r-.$ ’AGg UNCLASSIFIED Volume 7...Bypass, Potable-Water Disinfection,_ and Water-Quality Analysis Techniques; and Vol. 9, Data for Assessing Health Risks in Potential Theaters of Operation ...cleaning the RO elements, with objectives of improving solute rejection and reducing operating pressure. The most common method is to flush citric acid

  4. Morphology and Length Correlated in Terminal Flushes of Longleaf Pine Saplings

    Treesearch

    R.M. Allen; N.M. Scarbrough

    1970-01-01

    In longleafpine (Pinuspalustris Mill.) saplings growing in southern Mississippi the length of the first or spring flush was significantly correlated with that of the second flush; the correlation of length between flushes two and three was also statistically significant. The correlations were due more to similarities in internode elongation than to node number. Flush...

  5. Hypolimnetic dissolved-oxygen dynamics within selected White River reservoirs, northern Arkansas-southern Missouri, 1974-2008

    USGS Publications Warehouse

    De Lanois, Jeanne L.; Green, W. Reed

    2011-01-01

    Dissolved oxygen is a critical constituent in reservoirs and lakes because it is essential for metabolism by all aerobic aquatic organisms. In general, hypolimnetic temperature and dissolved-oxygen concentrations vary from summer to summer in reservoirs, more so than in natural lakes, largely in response to the magnitude of flow into and release out of the water body. Because eutrophication is often defined as the acceleration of biological productivity resulting from increased nutrient and organic loading, hypolimnetic oxygen consumption rates or deficits often provide a useful tool in analyzing temporal changes in water quality. This report updates a previous report that evaluated hypolimnetic dissolved-oxygen dynamics for a 21-year record (1974-94) in Beaver, Table Rock, Bull Shoals, and Norfork Lakes, as well as analyzed the record for Greers Ferry Lake. Beginning in 1974, vertical profiles of temperature and dissolved-oxygen concentrations generally were collected monthly from March through December at sites near the dam of each reservoir. The rate of change in the amount of dissolved oxygen present below a given depth at the beginning and end of the thermal stratification period is referred to as the areal hypolimnetic oxygen deficit. Areal hypolimnetic oxygen deficit was normalized for each reservoir based on seasonal flushing rate between April 15 and October 31 to adjust for wet year and dry year variability. Annual cycles in thermal stratification within Beaver, Table Rock, Bull Shoals, Norfork, and Greers Ferry Lakes exhibited typical monomictic (one extended turnover period per year) characteristics. Flow dynamics drive reservoir processes and need to be considered when analyzing areal hypolimnetic oxygen deficit rates. A nonparametric, locally weighted scatter plot smooth line describes the relation between areal hypolimnetic oxygen deficit and seasonal flushing rates, without assuming linearity or normality of the residuals. The results in this report are consistent with earlier findings that oxygen deficit rates and flushing-rate adjusted areal hypolimnetic oxygen deficit in Beaver and Table Rock Lakes were decreasing between 1974 and 1994. The additional data (1995-2008) demonstrate that the decline in flushing-rate adjusted areal hypolimnetic oxygen deficit in Beaver Lake has continued, whereas that in Table Rock Lake has flattened out in recent years. The additional data demonstrate the flushing-rate adjusted areal hypolimnetic oxygen deficit in Bull Shoals and Norfork Lakes have declined since 1995 (improved water quality), which was not indicated in earlier studies, while Greers Ferry Lake showed little net change over the period of record. Given the amount of data (35 years) for these reservoirs, developing an equation or model to predict areal hypolimnetic oxygen deficit and, therefore, areal hypolimnetic oxygen content, on any given day during future stratification seasons may be useful for reservoir managers.

  6. Measures for groundwater security during and after the Hanshin-Awaji earthquake (1995) and the Great East Japan earthquake (2011), Japan

    NASA Astrophysics Data System (ADS)

    Tanaka, Tadashi

    2016-03-01

    Many big earthquakes have occurred in the tectonic regions of the world, especially in Japan. Earthquakes often cause damage to crucial life services such as water, gas and electricity supply systems and even the sewage system in urban and rural areas. The most severe problem for people affected by earthquakes is access to water for their drinking/cooking and toilet flushing. Securing safe water for daily life in an earthquake emergency requires the establishment of countermeasures, especially in a mega city like Tokyo. This paper described some examples of groundwater use in earthquake emergencies, with reference to reports, books and newspapers published in Japan. The consensus is that groundwater, as a source of water, plays a major role in earthquake emergencies, especially where the accessibility of wells coincides with the emergency need. It is also important to introduce a registration system for citizen-owned and company wells that can form the basis of a cooperative during a disaster; such a registration system was implemented by many Japanese local governments after the Hanshin-Awaji Earthquake in 1995 and the Great East Japan Earthquake in 2011, and is one of the most effective countermeasures for groundwater use in an earthquake emergency. Emphasis is also placed the importance of establishing of a continuous monitoring system of groundwater conditions for both quantity and quality during non-emergency periods.

  7. Life Cycle Assessment and Cost Analysis of Water and ...

    EPA Pesticide Factsheets

    changes in drinking and wastewater infrastructure need to incorporate a holistic view of the water service sustainability tradeoffs and potential benefits when considering shifts towards new treatment technology, decentralized systems, energy recovery and reuse of treated wastewater. The main goal of this study is to determine the influence of scale on the energy and cost performance of different transitional membrane bioreactors (MBR) in decentralized wastewater treatment (WWT) systems by performing a life cycle assessment (LCA) and cost analysis. LCA is a tool used to quantify sustainability-related metrics from a systems perspective. The study calculates the environmental and cost profiles of both aerobic MBRs (AeMBR) and anaerobic MBRs (AnMBR), which not only recover energy from waste, but also produce recycled water that can displace potable water for uses such as irrigation and toilet flushing. MBRs represent an intriguing technology to provide decentralized WWT services while maximizing resource recovery. A number of scenarios for these WWT technologies are investigated for different scale systems serving various population density and land area combinations to explore the ideal application potentials. MBR systems are examined from 0.05 million gallons per day (MGD) to 10 MGD and serve land use types from high density urban (100,000 people per square mile) to semi-rural single family (2,000 people per square mile). The LCA and cost model was built with ex

  8. International Space Station Water Balance Operations

    NASA Technical Reports Server (NTRS)

    Tobias, Barry; Garr, John D., II; Erne, Meghan

    2011-01-01

    In November 2008, the Water Regenerative System racks were launched aboard Space Shuttle flight, STS-126 (ULF2) and installed and activated on the International Space Station (ISS). These racks, consisting of the Water Processor Assembly (WPA) and Urine Processor Assembly (UPA), completed the installation of the Regenerative (Regen) Environmental Control and Life Support Systems (ECLSS), which includes the Oxygen Generation Assembly (OGA) that was launched 2 years prior. With the onset of active water management on the US segment of the ISS, a new operational concept was required, that of water balance . In November of 2010, the Sabatier system, which converts H2 and CO2 into water and methane, was brought on line. The Regen ECLSS systems accept condensation from the atmosphere, urine from crew, and processes that fluid via various means into potable water, which is used for crew drinking, building up skip-cycle water inventory, and water for electrolysis to produce oxygen. Specification (spec) rates of crew urine output, condensate output, O2 requirements, toilet flush water, and drinking needs are well documented and used as the best guess planning rates when Regen ECLSS came online. Spec rates are useful in long term planning, however, daily or weekly rates are dependent upon a number of variables. The constantly changing rates created a new challenge for the ECLSS flight controllers, who are responsible for operating the ECLSS systems onboard ISS from Mission Control in Houston. This paper reviews the various inputs to water planning, rate changes, and dynamic events, including but not limited to: crew personnel makeup, Regen ECLSS system operability, vehicle traffic, water storage availability, and Carbon Dioxide Removal Assembly (CDRA), Sabatier, and OGA capability. Along with the inputs that change the various rates, the paper will review the different systems, their constraints, and finally the operational challenges and means by which flight controllers manage this new concept of "water balance."

  9. Rheological characterisation of concentrated domestic slurry.

    PubMed

    Thota Radhakrishnan, A K; van Lier, J B; Clemens, F H L R

    2018-05-03

    The much over-looked element in new sanitation, the transport systems which bridge the source and treatment facilities, is the focus of this study. The knowledge of rheological properties of concentrated domestic slurry is essential for the design of the waste collection and transport systems. To investigate these properties, samples were collected from a pilot sanitation system in the Netherlands. Two types of slurries were examined: black water (consisting of human faecal waste, urine, and flushed water from vacuum toilets) and black water with ground kitchen waste. Rheograms of these slurries were obtained using a narrow gap rotating rheometer and modelled using a Herschel-Bulkley model. The effect of concentration on the slurry are described through the changes in the parameters of the Herschel-Bulkley model. A detailed method is proposed on estimating the parameters for the rheological models. For the black water, yield stress and consistency index follow an increasing power law with the concentration and the behaviour index follows a decreasing power law. The influence of temperature on the viscosity of the slurry is described using an Arrhenius type relation. The viscosity of black water decreases with temperature. As for the black water mixed with ground kitchen waste, it is found that the viscosity increases with concentration and decreases with temperature. The viscosity of black-water with ground kitchen waste is found to be higher than that of black water, which can be attributed to the presence of larger particles in the slurry. Copyright © 2018 The Authors. Published by Elsevier Ltd.. All rights reserved.

  10. Changes in the character of stream water dissolved organic carbon during flushing in three small watersheds, Oregon.

    Treesearch

    Eran Hood; Michael N. Gooseff; Sherri L. Johnson

    2006-01-01

    The hydrologic and biogeochemical responses of forested watersheds to inputs of rainfall and snowmelt can be an indicator of internal watershed function. In this study, we assess how the quantity and quality, both chemical and spectroscopic, of stream water DOC changes in response to a 6-day storm event during the wet season of 2003 in three small (2...

  11. Asynchronous Amazon Forest Canopy Phenology Indicates Adaptation to Both Water and Light Availability

    NASA Astrophysics Data System (ADS)

    Jones, M. O.; Kimball, J. S.; Nemani, R. R.

    2015-12-01

    Amazon forests represent nearly half of all tropical vegetation biomass and, through photosynthesis and respiration, annually process more than twice the amount of estimated carbon (CO2) from fossil fuel emissions. Yet the seasonality of Amazon canopy cover, and the extent to which seasonal fluctuations in water availability and photosynthetically active radiation influence these processes, is still poorly understood. Implementing six remotely sensed data sets spanning nine years (2003-2011), with reported field and flux tower data, we show that southern equatorial Amazon forests exhibit a distinctive seasonal signal. Seasonal timing of water availability, canopy biomass growth and net leaf flush are asynchronous in regions with short dry seasons and become more synchronous across a west-to-east longitudinal moisture gradient of increasing dry season length. Forest cover is responsive to seasonal disparities in both water and solar radiation availability, temporally adjusting net leaf flush to maximize use of these generally abundant resources, while reducing drought susceptibility. An accurate characterization of this asynchronous behavior allows for improved understanding of canopy phenology across contiguous tropical forests and their sensitivity to climate variability and drought. These insights can also inform land surface models to provide a more accurate representation of seasonal forest carbon allocation strategies responsive to environmental drivers.

  12. Hydrodynamics and eutrophication in a mariculture site in the Philippines

    NASA Astrophysics Data System (ADS)

    Escobar, M. T.; San Diego-McGlone, M. L.; Martin, M.; Villanoy, C.

    2014-12-01

    Bolinao, Pangasinan in the Philippines is a site for extensive and intensive culture of Chanos chanos. The proliferation of fish farm structures coupled with excessive feeding caused the deterioration of water quality in the area that lead to hypoxic condition (<2mg/L) and fish kills. A hydrodynamic model of the area, developed using DELFT3D, showed a residence time of 5-15 days in the northern channel and 25 to 28 days in the southern end. The complex configuration of the coast, which includes narrow channels that serve as bottlenecks, result to the inefficient flushing of the area. This was further aggravated by the presence of fish farm structures that restricted the natural flow of water. Water quality was monitored in the mariculture site and a nearby seagrass reserve. Nitrate+nitrite concentration ranged from 0.34 - 4.1 µM, 0.13 - 2.7 µM for phosphate, and 1.7 - 8.8 µM for ammonia. Highest nutrient concentrations were seen near the fish farms. Analysis of nutrients, chlorophyll-a and tss for a tidal cycle showed that these substances were inadequately flushed from the coastal waters. Long residence times and high nutrient loading in the area were ideal conditions for the development of hypoxia.

  13. The influence of small-scale interlayer heterogeneity on DDT removal efficiency for flushing technology.

    PubMed

    Wang, Xingwei; Chen, Jiajun

    2017-06-01

    With an aim to investigate the influence of small-scale interlayer heterogeneity on DDT removal efficiency, batch test including surfactant-stabilized foam flushing and solution flushing were carried out. Two man-made heterogeneous patterns consisting of coarse and fine quartz sand were designed to reveal the influencing mechanism. Moreover, the removal mechanism and the corresponding contribution by foam flushing were quantitatively studied. Compared with surfactant solution flushing, the DDT removal efficiency by surfactant-stabilized foam flushing increased by 9.47% and 11.28% under heterogeneous patterns 1 and 2, respectively. The DDT removal contributions of improving sweep efficiency for heterogeneous patterns 1 and 2 by foam flushing were 40.82% and 45.98%, and the contribution of dissolving capacity were 59.18% and 54.02%, respectively. The dissolving capacity of DDT played a major role in DDT removal efficiency by foam flushing under laboratory conditions. And the DDT removal contribution of significant improving sweep efficiency was higher than that of removal decline caused by weak solubilizing ability of foam film compared with solution flushing. The obtained results indicated that the difference of DDT removal efficiency by foam flushing was decreased under two different heterogeneous patterns with the increase of the contribution of improving foam flushing sweep efficiency. It suggested that foam flushing can reduce the disturbance from interlayer heterogeneity in remediating DDT contaminated heterogeneous medium. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Impact of Biofilms on the Design and Operation of ISS Life Support Systems

    NASA Technical Reports Server (NTRS)

    Carter, Donald Layne; Brown, Chris

    2017-01-01

    Biofilm growth has been an ongoing issue for US and Russian water systems on the International Space Station, and is a critical issue for exploration missions in which water systems must be designed to accommodate dormant periods of up to one year. On ISS, Russian condensate plumbing has previously clogged with biomass, requiring condensate plumbing to now be regularly replaced. In the US Segment, the release of biofilm from the Water Processor waste tank has clogged a solenoid valve downstream of the tank, resulting in the costly replacement of the inlet separator and process pump. Subsequent management of the biofilm in the waste tank involves restrictions on tank cycles to limit the release of biomass and an additional filter to protect downstream components. Engineering personnel are now evaluating concepts to better manage the biomass, including the use of microbial inhibitors and UV LEDs. Though current ISS operations could likely be sustained for the duration of ISS, a more effective method must be developed for managing the growth and release of biomass in future exploration vehicles. Biofilm management for future missions is complicated by the requirement to accommodate extended periods of dormancy during which time the water system will be stagnant. The current approach under consideration is to flush the waste water with product water to reduce the organic content followed by use of microbial inhibitors or UV. However, other concepts may also be developed based on ongoing research.

  15. Distribution and Recovery of Crude Oil in Various Types of Porous Media and Heterogeneity Configurations

    NASA Astrophysics Data System (ADS)

    Tick, G. R.; Ghosh, J.; Greenberg, R. R.; Akyol, N. H.

    2015-12-01

    A series of pore-scale experiments were conducted to understand the interfacial processes contributing to the removal of crude oil from various porous media during surfactant-induced remediation. Effects of physical heterogeneity (i.e. media uniformity) and carbonate soil content on oil recovery and distribution were evaluated through pore scale quantification techniques. Additionally, experiments were conducted to evaluate impacts of tetrachloroethene (PCE) content on crude oil distribution and recovery under these same conditions. Synchrotron X-ray microtomography (SXM) was used to obtain high-resolution images of the two-fluid-phase oil/water system, and quantify temporal changes in oil blob distribution, blob morphology, and blob surface area before and after sequential surfactant flooding events. The reduction of interfacial tension in conjunction with the sufficient increase in viscous forces as a result of surfactant flushing was likely responsible for mobilization and recovery of lighter fractions of crude oil. Corresponding increases in viscous forces were insufficient to initiate and maintain the displacement of the heavy crude oil in more homogeneous porous media systems during surfactant flushing. Interestingly, higher relative recoveries of heavy oil fractions were observed within more heterogeneous porous media indicating that wettability may be responsible for controlling mobilization in these systems. Compared to the "pure" crude oil experiments, preliminary results show that crude oil with PCE produced variability in oil distribution and recovery before and after each surfactant-flooding event. Such effects were likely influenced by viscosity and interfacial tension modifications associated with the crude-oil/solvent mixed systems.

  16. Organic matter degradation in a greywater recycling system using a multistage moving bed biofilm reactor (MBBR).

    PubMed

    Saidi, Assia; Masmoudi, Khaoula; Nolde, Erwin; El Amrani, Btissam; Amraoui, Fouad

    2017-12-01

    Greywater is an important non-conventional water resource which can be treated and recycled in buildings. A decentralized greywater recycling system for 223 inhabitants started operating in 2006 in Berlin, Germany. High load greywater undergoes advanced treatment in a multistage moving bed biofilm reactor (MBBR) followed by sand filtration and UV disinfection. The treated water is used safely as service water for toilet flushing. Monitoring of the organic matter degradation was pursued to describe the degradation processes in each stage and optimize the system. Results showed that organic matter reduction was achieved for the most part in the first three reactors, whereas the highest reduction rate was observed in the third reactor in terms of COD (chemical oxygen demand), dissolved organic carbon and BOD 7 (biological oxygen demand). The results also showed that the average loading rate entering the system was 3.7 kg COD/d, while the removal rate was 3.4 kg COD/d in a total bioreactor volume of 11.7 m³. In terms of BOD, the loading rate was 2.8 kg BOD/d and it was almost totally removed. This system requires little space (0.15 m²/person) and maintenance work of less than one hour per month and it shows operational stability under peak loads.

  17. A comparison of physicochemical methods for the remediation of porous medium systems contaminated with tar

    NASA Astrophysics Data System (ADS)

    Hauswirth, Scott C.; Miller, Cass T.

    2014-10-01

    The remediation of former manufactured gas plant (FMGP) sites contaminated with tar DNAPLs (dense non-aqueous phase liquids) presents a significant challenge. The tars are viscous mixtures of thousands of individual compounds, including known and suspected carcinogens. This work investigates the use of combinations of mobilization, solubilization, and chemical oxidation approaches to remove and degrade tars and tar components in porous medium systems. Column experiments were conducted using several flushing solutions, including an alkaline-polymer (AP) solution containing NaOH and xanthan gum (XG), a surfactant-polymer (SP) solution containing Triton X-100 surfactant (TX100) and XG, an alkaline-surfactant-polymer (ASP) solution containing NaOH, TX100, and XG, and base-activated sodium persulfate both with and without added TX100. The effectiveness of the flushing solutions was assessed based on both removal of polycyclic aromatic hydrocarbon (PAH) mass and on the reduction of dissolved-phase PAH concentrations. SP flushes of 6.6 to 20.9 PV removed over 99% of residual PAH mass and reduced dissolved-phase concentrations by up to two orders of magnitude. ASP flushing efficiently removed 95-96% of residual PAH mass within about 2 PV, and significantly reduced dissolved-phase concentrations of several low molar mass compounds, including naphthalene, acenaphthene, fluorene, and phenanthrene. AP flushing removed a large portion of the residual tar (77%), but was considerably less effective than SP and ASP in terms of the effect on dissolved PAH concentrations. Persulfate was shown to oxidize tar components, primarily those with low molar mass, however, the overall degradation was relatively low (30-50% in columns with low initial tar saturations), and the impact on dissolved-phase concentrations was minimal.

  18. 21 CFR 520.2325a - Sulfaquinoxaline drinking water.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ...) Chickens. (i) As an aid in the control of outbreaks of coccidiosis caused by Eimeria tenella, E. necatrix... not change litter unless absolutely necessary. Do not give flushing mashes. (3) Chickens and turkeys... sulfaquinoxaline and fowl typhoid caused by Salmonella gallinarum susceptible to sulfaquinoxaline. (ii) Administer...

  19. 21 CFR 520.2325a - Sulfaquinoxaline drinking water.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ...) Chickens. (i) As an aid in the control of outbreaks of coccidiosis caused by Eimeria tenella, E. necatrix... not change litter unless absolutely necessary. Do not give flushing mashes. (3) Chickens and turkeys... sulfaquinoxaline and fowl typhoid caused by Salmonella gallinarum susceptible to sulfaquinoxaline. (ii) Administer...

  20. 21 CFR 520.2325a - Sulfaquinoxaline drinking water.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ...) Chickens. (i) As an aid in the control of outbreaks of coccidiosis caused by Eimeria tenella, E. necatrix... not change litter unless absolutely necessary. Do not give flushing mashes. (3) Chickens and turkeys... sulfaquinoxaline and fowl typhoid caused by Salmonella gallinarum susceptible to sulfaquinoxaline. (ii) Administer...

  1. 40 CFR 61.131 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... circulation tank means any vessel that functions to store or contain flushing liquor that is separated from... that functions to condense benzene-containing vapors. Light-oil decanter means any vessel, tank, or other type of device in the light-oil recovery operation that functions to separate light oil from water...

  2. 40 CFR 61.131 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... circulation tank means any vessel that functions to store or contain flushing liquor that is separated from... that functions to condense benzene-containing vapors. Light-oil decanter means any vessel, tank, or other type of device in the light-oil recovery operation that functions to separate light oil from water...

  3. 40 CFR 61.131 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... circulation tank means any vessel that functions to store or contain flushing liquor that is separated from... that functions to condense benzene-containing vapors. Light-oil decanter means any vessel, tank, or other type of device in the light-oil recovery operation that functions to separate light oil from water...

  4. Efficacy of a Novel Narrow Knife with Water Jet Function for Colorectal Endoscopic Submucosal Dissection.

    PubMed

    Yoshida, Naohisa; Toyonaga, Takashi; Murakami, Takaaki; Hirose, Ryohei; Ogiso, Kiyoshi; Inada, Yutaka; Rani, Rafiz Abdul; Naito, Yuji; Kishimoto, Mitsuo; Ohara, Yoshiko; Azuma, Takeshi; Itoh, Yoshito

    2017-01-01

    With respect to the knife's design in colorectal endoscopic submucosal dissection (ESD), diameter, water jet function, and electric power are important because these relate to efficient dissection. In this study, we analyzed a novel, narrow ball tip-typed ESD knife with water jet function (Flush knife BT-S, diameter: 2.2 mm, length: 2000 mm, Fujifilm Co., Tokyo, Japan) compared to a regular diameter knife (Flush knife BT, diameter: 2.6 mm, length: 1800 mm). In laboratory and clinical research, electric power, knife insertion time, vacuum/suction amount with knife in the endoscopic channel, and water jet function were analyzed. We used a knife 2.0 mm long for BT-S and BT knives. The BT-S showed faster mean knife insertion time (sec) and better vacuum amount (ml/min) compared to the BT (insertion time: 16.7 versus 21.6, p < 0.001, vacuum amount: 38.0 versus 14.0, p < 0.01). Additionally, the water jet function of the BT-S was not inferior. In 39 colorectal ESD cases in two institutions, there were mean 4.7 times (range: 1-28) of knife insertion. Suction under knife happened 59% (23/39) and suction of fluid could be done in 100%. Our study showed that the narrow knife allows significantly faster knife insertion, better vacuum function, and effective clinical results.

  5. Hot flushes, coronary heart disease, and hormone therapy in postmenopausal women

    PubMed Central

    Huang, Alison J.; Sawaya, George F.; Vittinghoff, Eric; Lin, Feng; Grady, Deborah

    2010-01-01

    Objective The aim of this study was to examine interactions between hot flushes, estrogen plus progestogen therapy (EPT), and coronary heart disease (CHD) events in postmenopausal women with CHD. Methods We analyzed data from the Heart and Estrogen/Progestin Replacement Study, a randomized, placebo-controlled trial of 0.625 mg conjugated equine estrogens plus 2.5 mg medroxyprogesterone acetate in 2,763 postmenopausal women with CHD. Hot flushes were assessed at baseline using self-administered questionnaires; women reporting bothersome hot flushes “some” to ”all” of the time were considered to have clinically significant flushing. Cox regression models were used to examine the effect of EPT on risk of CHD events among women with and without significant flushing at baseline. Results The mean age of participants was 66.7 ± 6.8 years, and 89% (n = 2,448) were white. Sixteen percent (n = 434) of participants reported clinically significant hot flushes at baseline. Among women with baseline flushing, EPT increased risk of CHD events nine-fold in the first year compared with placebo (hazard ratio = 9.01; 95% CI, 1.15-70.35); among women without baseline flushing, treatment did not significantly affect CHD event risk in the first year (hazard ratio = 1.32; 95% CI, 0.86-2.03; P = 0.07 for interaction of hot flushes with treatment). The trend toward differential effects of EPT on risk for CHD among women with and without baseline flushing did not persist after the first year of treatment. Conclusions Among older postmenopausal women with CHD, EPT may increase risk of CHD events substantially in the first year of treatment among women with clinically significant hot flushes but not among those without hot flushes. PMID:19325499

  6. Numerical investigation of road salt impact on an urban wellfield.

    PubMed

    Bester, M L; Frind, E O; Molson, J W; Rudolph, D L

    2006-01-01

    The impact of road salt on a wellfield in a complex glacial moraine aquifer system is studied by numerical simulation. The moraine underlies an extensive urban and industrial landscape, which draws its water supply from >20 wellfields, several of which are approaching or have exceeded the drinking water limit for chloride. The study investigates the mechanisms of road salt infiltration, storage, and transport in the subsurface and assesses the effectiveness of mitigation measures designed to reduce the impact. The three-dimensional transport model accounts for increases in salt loading, as well as growth of the urbanized area and road network over the past 50 years. The simulations, which focus on one impacted wellfield, show chloride plumes originating mainly at arterial roads and migrating through aquitard windows into the water supply aquifers. The results suggest that the aquifer system contains a large and heterogeneously distributed mass of chloride and that concentrations in the aquifer can be substantially higher than the concentrations in the well water. Future impact scenarios indicate that although the system responds rapidly to reductions in salt loading, the residual chloride mass may take decades to flush out, even if road salting were discontinued. The implications with respect to urban wellfields in typical snow-belt areas are discussed.

  7. Past leaded gasoline emissions as a nonpoint source tracer in riparian systems: A study of river inputs to San Francisco Bay

    USGS Publications Warehouse

    Dunlap, C.E.; Bouse, R.; Flegal, A.R.

    2000-01-01

    Variations in the isotopic composition of lead in 1995-1998 river waters flowing into San Francisco Bay trace the washout of lead deposited in the drainage basin from leaded gasoline combustion. At the confluence of the Sacramento and San Joaquin rivers where they enter the Bay, the isotopic compositions of lead in the waters define a linear trend away from the measured historical compositions of leaded gas in California. The river waters are shifted away from leaded gasoline values and toward an isotopic composition similar to Sierra Nevadan inputs which became the predominant source of sedimentation in San Francisco Bay following the onset of hydraulic gold mining in 1853. Using lead isotopic compositions of hydraulic mine sediments and average leaded gasoline as mixing end members, we calculate that more than 50% of the lead in the present river water originated from leaded gasoline combustion. The strong adsorption of lead (log K(d) > 7.4) to particulates appears to limit the flushing of gasoline lead from the drainage basin, and the removal of that lead from the system may have reached an asymptotic limit. Consequently, gasoline lead isotopes should prove to be a useful nonpoint source tracer of the environmental distribution of particle- reactive anthropogenic metals in freshwater systems.

  8. Effect of hydrofracking fluid on colloid transport in the unsaturated zone.

    PubMed

    Sang, Wenjing; Stoof, Cathelijne R; Zhang, Wei; Morales, Verónica L; Gao, Bin; Kay, Robert W; Liu, Lin; Zhang, Yalei; Steenhuis, Tammo S

    2014-07-15

    Hydraulic fracturing is expanding rapidly in the US to meet increasing energy demand and requires high volumes of hydrofracking fluid to displace natural gas from shale. Accidental spills and deliberate land application of hydrofracking fluids, which return to the surface during hydrofracking, are common causes of environmental contamination. Since the chemistry of hydrofracking fluids favors transport of colloids and mineral particles through rock cracks, it may also facilitate transport of in situ colloids and associated pollutants in unsaturated soils. We investigated this by subsequently injecting deionized water and flowback fluid at increasing flow rates into unsaturated sand columns containing colloids. Colloid retention and mobilization was measured in the column effluent and visualized in situ with bright field microscopy. While <5% of initial colloids were released by flushing with deionized water, 32-36% were released by flushing with flowback fluid in two distinct breakthrough peaks. These peaks resulted from 1) surface tension reduction and steric repulsion and 2) slow kinetic disaggregation of colloid flocs. Increasing the flow rate of the flowback fluid mobilized an additional 36% of colloids, due to the expansion of water filled pore space. This study suggests that hydrofracking fluid may also indirectly contaminate groundwater by remobilizing existing colloidal pollutants.

  9. Using continuous in-situ measurements to adaptively trigger urban storm water samples

    NASA Astrophysics Data System (ADS)

    Wong, B. P.; Kerkez, B.

    2015-12-01

    Until cost-effective in-situ sensors are available for biological parameters, nutrients and metals, automated samplers will continue to be the primary source of reliable water quality measurements. Given limited samples bottles, however, autosamplers often obscure insights on nutrient sources and biogeochemical processes which would otherwise be captured using a continuous sampling approach. To that end, we evaluate the efficacy a novel method to measure first-flush nutrient dynamics in flashy, urban watersheds. Our approach reduces the number of samples required to capture water quality dynamics by leveraging an internet-connected sensor node, which is equipped with a suite of continuous in-situ sensors and an automated sampler. To capture both the initial baseflow as well as storm concentrations, a cloud-hosted adaptive algorithm analyzes the high-resolution sensor data along with local weather forecasts to optimize a sampling schedule. The method was tested in a highly developed urban catchment in Ann Arbor, Michigan and collected samples of nitrate, phosphorus, and suspended solids throughout several storm events. Results indicate that the watershed does not exhibit first flush dynamics, a behavior that would have been obscured when using a non-adaptive sampling approach.

  10. Hourly Water Quality Dynamics in Rivers Downstream of Urban Areas: Quantifying Seasonal Variation and Modelling Impacts of Urban Growth

    NASA Astrophysics Data System (ADS)

    Hutchins, M.; McGrane, S. J.; Miller, J. D.; Hitt, O.; Bowes, M.

    2016-12-01

    Continuous monitoring of water flows and quality is invaluable in improving understanding of the influence of urban areas on river health. When used to inform predictive modelling, insights can be gained as to how urban growth may affect the chemical and biological quality of rivers as they flow downstream into larger waterbodies. Water flow and quality monitoring in two urbanising sub-catchments (<100 km2) of the River Thames (southern UK) is described. Temperature, conductivity, turbidity, dissolved oxygen (DO) and ammonium (NH4) were measured at downstream locations where long term flow records are available, but particular focus is given to monitoring of an extended set of sites during prolonged winter rainfall. In the Ray sub-catchment streams were monitored in which urban cover varied across a range of 7-78%. A rural-urban gradient in DO was apparent in the low flow period prior to the storms. Transient low DO (< 8 mg L-1) as a response to pollutant first flushes was particularly apparent in urban streams but this was followed by a rapid recovery. Chronic effects lasting for three to four weeks were only seen downstream of a sewage treatment works (STW). In this respect temperature- and respiration-driven DO sags in summer were at least if not more severe than those driven by the winter storms. Likewise, although winter storm NH4 concentrations violated EU legislation downstream of the STW, they were lower than summer concentrations in pollutant flushes following dry spells. In contrast the predominant phenomenon affecting water quality in the Cut during the storms was dilution. Here, a river water quality model was calibrated and applied over the course of a year to capture the importance of periphyton photosynthesis and respiration cycles in determining water quality and to predict the influence of hypothetical urban growth on downstream river health. The periods monitored intensively, dry spells followed by prolonged rainfall, represent: (i) marked changes in conditions likely to become more prevalent in future, (ii) situations under which water quality in urban areas is likely to be particularly vulnerable, being influenced for example by first flush effects followed by capacity exceedance at STW. Despite this, whilst being somewhat long lasting in places, impacts on DO were not severe.

  11. Influence of headspace flushing on methane production in Biochemical Methane Potential (BMP) tests.

    PubMed

    Koch, Konrad; Bajón Fernández, Yadira; Drewes, Jörg E

    2015-06-01

    The influence of headspace flushing on the specific methane (CH4) production of blank samples with just inoculum in Biochemical Methane Potential (BMP) tests was studied. The three most common ways were applied: flushing with nitrogen (N2) gas, flushing with a mixture of N2 and CO2 (80/20 v/v), and no flushing. The results revealed that removing the oxygen is crucial to avoid aerobic respiration, which caused both hindered activity of methanogens and loss of methane potential. Furthermore it was demonstrated that 20% of CO2 in the flush gas increased significantly the methane production by over 20% compared to the flushing with pure N2. In order to mimic the same headspace conditions as in full-scale treatment plants, using a flush gas with a similar CO2 concentration as the expected biogas is suggested. Copyright © 2015 Elsevier Ltd. All rights reserved.

  12. Statistical modelling of suspended sediment load in small basin located at Colombian Andes

    NASA Astrophysics Data System (ADS)

    Javier, Montoya Luis

    2016-04-01

    In this study a statistical modelling for the estimate the sediment yield based on available observations of water discharge and suspended sediment concentration were done. A multivariate model was applicate to analyze the 33 years of daily suspended sediments load available at a La Garrucha gauging station. A regional analysis were conducted to find a non-dimensional sediment load duration curve. These curves were used to estimate flow and sediments regimen at other inner point at the basin where there are located the Calderas reservoir. The record of sedimentation in the reservoir were used to validate the estimate mean sediments load. A periodical flushing in the reservoir is necessary to maintain the reservoir at the best operating capacity. The non-dimensional sediment load duration curve obtaining was used to find a sediment concentration during high flow regimen (10% of time these values were met or exceeded).These sediment concentration of high flow regimen has been assumed as a concentration that allow an 'environmental flushing', because it try to reproduce the natural regimen of sediments at the river and it sends a sediment concentration that environment can withstand. The sediment transport capacity for these sediment load were verified with a 1D model in order to respect the environmental constraints downstream of the dam. Field data were collected to understand the physical phenomena involved in flushing dynamics in the reservoir and downstream of the dam. These model allow to define an operations rules for the flushing to minimize the environmental effects.

  13. Quantifying groundwater discharge through fringing wetlands to estuaries: Seasonal variability, methods comparison, and implications for wetland-estuary exchange

    USGS Publications Warehouse

    Tobias, C.R.; Harvey, J.W.; Anderson, I.C.

    2001-01-01

    Because groundwater discharge along coastal shorelines is often concentrated in zones inhabited by fringing wetlands, accurately estimating discharge is essential for understanding its effect on the function and maintenance of these ecosystems. Most previous estimates of groundwater discharge to coastal wetlands have been temporally limited and have used only a single approach to estimate discharge. Furthermore, groundwater input has not been considered as a major mechanism controlling pore-water flushing. We estimated seasonally varying groundwater discharge into a fringing estuarine wetland using three independent methods (Darcy's Law, salt balance, and Br- tracer). Seasonal patterns of discharge predicted by both Darcy's Law and the salt balance yielded similar seasonal patterns with discharge maxima and minima in spring and early fall, respectively. They differed, however, in the estimated magnitude of discharge by two- to fourfold in spring and by 10-fold in fall. Darcy estimates of mean discharge ranged between -8.0 and 80 L m-2 d-1, whereas the salt balance predicted groundwater discharge of 0.6 to 22 L m-2 d-1. Results from the Br- tracer experiment estimated discharge at 16 L m-2 d-t, or nearly equal to the salt balance estimate at that time. Based upon the tracer test, pore-water conductivity profiles, and error estimates for the Darcy and salt balance approaches, we concluded that the salt balance provided a more certain estimate of groundwater discharge at high flow (spring). In contrast, the Darcy method provided a more reliable estimate during low flow (fall). Groundwater flushing of pore water in the spring exported solutes to the estuary at rates similar to tidally driven surface exchange seen in previous studies. Based on pore-water turnover times, the groundwater-driven flux of dissolved organic carbon (DOC), dissolved organic nitrogen (DON), and NH4+ to the estuary was 11.9, 1.6, and 1.3 g C or g N m-2 wetland for the 90 d encompassing peak spring discharge. Groundwater-induced flushing of the wetland subsurface therefore represents an important mechanism by which narrow fringing marshes may seasonally relieve salt stress and export material to adjacent water masses.

  14. Gross decontamination experiment report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mason, R.; Kinney, K.; Dettorre, J.

    1983-07-01

    A Gross Decontamination Experiment was conducted on various levels and surfaces of the TMI - Unit 2 reactor building in March 1982. The polar crane, D-rings, missile shields, refueling canals, refueling bridges, equipment, and elevations 305' and 347'-6'' were flushed with low pressure water. Additionally, floor surfaces on elevation 305' and floor surfaces and major pieces of equipment on elevation 347'-6'' were sprayed with high pressure water. Selective surfaces were decontaminated with a mechanical scrubber and chemicals. Strippable coating was tested and evaluated on equipment and floor surfaces. The effectiveness, efficiency, and safety of several decontamination techniques were established formore » the large, complex decontamination effort. Various decontamination equipment was evaluated and its effectiveness was documented. Decontamination training and procedures were documented and evaluated, as were the support system and organization for the experiment.« less

  15. The Indian Ocean as a Connector

    NASA Astrophysics Data System (ADS)

    Durgadoo, J. V.; Biastoch, A.; Boning, C. W.

    2016-02-01

    The Indian Ocean is a conduit for the upper ocean flow of the global thermohaline circulation. It receives water from the Pacific Ocean through the Indonesian throughflow and the Tasman leakage, and exports water into the Atlantic by means of Agulhas leakage. A small contribution from the northern Indian Ocean is also detectable within Agulhas leakage. Changes on different timescales in the various components of the Pacific inflows and the Atlantic outflow have been reported. Little is known on the role of the Indian Ocean circulation in communicating changes from the Pacific into the Atlantic, let alone any eventual alterations in response to climate change. The precise routes and timescales of Indonesian throughflow, Tasman leakage, Red Sea and Persian Gulf Waters towards the Atlantic are examined in a Lagrangian framework within a high-resolution global ocean model. In this presentation, the following questions are addressed: How are Pacific waters modified in the Indian Ocean before reaching the Agulhas system? On what timescale is water that enters the Indian Ocean from the Pacific flushed out? How important are detours in the Bay of Bengal and Arabian Sea?

  16. U.S. National Park Service, National Mall and Memorial Parks, Washington, DC - DC00000345 & DC00000370

    EPA Pesticide Factsheets

    Public notice of draft permit and opportunity for public comment under the Clean Water Act to the National Park Service for discharges of comingled stormwater and pool flushings from the World War II Memorial and the Lincoln Memorial Reflecting Pool.

  17. 40 CFR 721.3000 - Dicarboxylic acid monoester.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... prevent dermal contact for any person involved in any processing or use operation where dermal contact may... prevent contact or exposure. —Promptly remove contaminated non-imprevious clothing, wash before reuse... smoking. —Keep container closed. FIRST AID: In case of contact. EYES: Immediately flush with water for at...

  18. 33 CFR 159.127 - Safety coliform count: Recirculating devices.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Safety coliform count....127 Safety coliform count: Recirculating devices. Thirty-eight of forty samples of flush fluid from a recirculating device must have less than 240 fecal coliform bacteria per 100 milliliters. These samples must be...

  19. DIAGNOSIS OF TRACE PB IN DOMESTIC WELLS, UPPER GLOUCESTER CATCHMENT, MAINE

    EPA Science Inventory

    Dissolved Pb in 32 wells associated with corroding submersible pumps is examined within a rural water district after almost 20 years (1984 to 2002). Groundwater Pb ranged from 0.4 – 24.9 µg L-1 after 24 hr pump flushing. Preliminary geochemistry and represent...

  20. Application of a water quality model in the White Cart water catchment, Glasgow, UK.

    PubMed

    Liu, S; Tucker, P; Mansell, M; Hursthouse, A

    2003-03-01

    Water quality models of urban systems have previously focused on point source (sewerage system) inputs. Little attention has been given to diffuse inputs and research into diffuse pollution has been largely confined to agriculture sources. This paper reports on new research that is aimed at integrating diffuse inputs into an urban water quality model. An integrated model is introduced that is made up of four modules: hydrology, contaminant point sources, nutrient cycling and leaching. The hydrology module, T&T consists of a TOPMODEL (a TOPography-based hydrological MODEL), which simulates runoff from pervious areas and a two-tank model, which simulates runoff from impervious urban areas. Linked into the two-tank model, the contaminant point source module simulates the overflow from the sewerage system in heavy rain. The widely known SOILN (SOIL Nitrate model) is the basis of nitrogen cycle module. Finally, the leaching module consists of two functions: the production function and the transfer function. The production function is based on SLIM (Solute Leaching Intermediate Model) while the transfer function is based on the 'flushing hypothesis' which postulates a relationship between contaminant concentrations in the receiving water course and the extent to which the catchment is saturated. This paper outlines the modelling methodology and the model structures that have been developed. An application of this model in the White Cart catchment (Glasgow) is also included.

  1. Ontogenetic patterns of CO sub 2 exchange of Quercus rubra L. leaves during three flushes of shoot growth II. insertion gradients of leaf photosynthesis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hanson, P.J.; Isebrands, J.G.; Dickson, R.E.

    1988-03-01

    Carbon dioxide exchange rates (CERs) of all leaves along the stem of northern red oak (Quercus rubra L.) seedlings (a leaf insertion gradient of profile) were determined at several stages of ontogeny. Seedlings were grown and measured under growth chamber conditions favorable for the production of multiple flushes of shoot growth. The CERs were measured with a portable closed-circuit CO{sub 2} analyzer at ambient photosynthetic photon flux densities and were determined for every leaf of each seedling. Carbon dioxide exchange rates per unit projected area of individual leaves (CERA) increased along leaf-maturation gradients in expanding flushes. After flush growth wasmore » completed, all leaves of a flush has similar CERA. However, because median flush leaves were the largest, they accounted for the greatest proportion of an expanded-flush's CER. First-flush leaves were the major contributors to total seedling CER through the second flush of growth-encompassing half of the period required to produce a three-flush oak seedling. This study's data, based on short-term CER measurements, showed ontogenetic pattern of CO{sub 2} exchange similar to those reported for northern red oak under steady state laboratory conditions.« less

  2. Exercise training reduces the acute physiological severity of post‐menopausal hot flushes

    PubMed Central

    Bailey, Tom G.; Cable, N. Timothy; Aziz, Nabil; Atkinson, Greg; Cuthbertson, Daniel J.; Low, David A.

    2016-01-01

    Key points A post‐menopausal hot flush consists of profuse physiological elevations in cutaneous vasodilatation and sweating that are accompanied by reduced brain blood flow. These responses can be used to objectively quantify hot flush severity.The impact of an exercise training intervention on the physiological responses occurring during a hot flush is currently unknown.In a preference‐controlled trial involving 21 post‐menopausal women, 16 weeks of supervised moderate intensity exercise training was found to improve cardiorespiratory fitness and attenuate cutaneous vasodilatation, sweating and the reductions in cerebral blood flow during a hot flush.It is concluded that the improvements in fitness that are mediated by 16 weeks of exercise training reduce the severity of physiological symptoms that occur during a post‐menopausal hot flush. Abstract A hot flush is characterised by feelings of intense heat, profuse elevations in cutaneous vasodilatation and sweating, and reduced brain blood flow. Exercise training reduces self‐reported hot flush severity, but underpinning physiological data are lacking. We hypothesised that exercise training attenuates the changes in cutaneous vasodilatation, sweat rate and cerebral blood flow during a hot flush. In a preference trial, 18 symptomatic post‐menopausal women underwent a passive heat stress to induce hot flushes at baseline and follow‐up. Fourteen participants opted for a 16 week moderate intensity supervised exercise intervention, while seven participants opted for control. Sweat rate, cutaneous vasodilatation, blood pressure, heart rate and middle cerebral artery velocity (MCAv) were measured during the hot flushes. Data were binned into eight equal segments, each representing 12.5% of hot flush duration. Weekly self‐reported frequency and severity of hot flushes were also recorded at baseline and follow‐up. Following training, mean hot flush sweat rate decreased by 0.04 mg cm2 min−1 at the chest (95% confidence interval 0.02–0.06, P = 0.01) and by 0.03 mg cm2 min−1 (0.02–0.05, P = 0.03) at the forearm, compared with negligible changes in control. Training also mediated reductions in cutaneous vasodilatation by 9% (6–12%) at the chest and by 7% (4–9%) at forearm (P ≤ 0.05). Training attenuated hot flush MCAv by 3.4 cm s−1 (0.7–5.1 cm s−1, P = 0.04) compared with negligible changes in control. Exercise training reduced the self‐reported severity of hot flushes by 109 arbitrary units (80–121, P < 0.001). These data indicate that exercise training leads to parallel reductions in hot flush severity and within‐flush changes in cutaneous vasodilatation, sweating and cerebral blood flow. PMID:26676059

  3. Characterization of elemental and structural composition of corrosion scales and deposits formed in drinking water distribution systems.

    PubMed

    Peng, Ching-Yu; Korshin, Gregory V; Valentine, Richard L; Hill, Andrew S; Friedman, Melinda J; Reiber, Steve H

    2010-08-01

    Corrosion scales and deposits formed within drinking water distribution systems (DWDSs) have the potential to retain inorganic contaminants. The objective of this study was to characterize the elemental and structural composition of extracted pipe solids and hydraulically-mobile deposits originating from representative DWDSs. Goethite (alpha-FeOOH), magnetite (Fe(3)O(4)) and siderite (FeCO(3)) were the primary crystalline phases identified in most of the selected samples. Among the major constituent elements of the deposits, iron was most prevalent followed, in the order of decreasing prevalence, by sulfur, organic carbon, calcium, inorganic carbon, phosphorus, manganese, magnesium, aluminum and zinc. The cumulative occurrence profiles of iron, sulfur, calcium and phosphorus for pipe specimens and flushed solids were similar. Comparison of relative occurrences of these elements indicates that hydraulic disturbances may have relatively less impact on the release of manganese, aluminum and zinc, but more impact on the release of organic carbon, inorganic carbon, and magnesium. (c) 2010 Elsevier Ltd. All rights reserved.

  4. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baca, B.J.; Getter, C.D.

    Turtle grass beds, a valuable natural resource, are diminishing throughout the tropics because of damage from dredging, boats, and other factors. The toxicity of chemical dispersants and crude oil to turtle grass was determined in the laboratory to assess the potential for damage from spills occurring in the field. Studies of water-soluble fractions (WSF) of crude oil in static bioassays showed that a chemical dispersant (Corexit 9527) increased the amount of total oil in water more than 50-fold. The toxicity of chemically dispersed oil was assessed by conventional (96-h 50% lethal concentration) methods in static systems, and the results weremore » compared with toxicity measurements where the system was flushed after 12 h. Prudhoe Bay crude WSF was more toxic than dispersed oil or dispersant alone, possibly because of the large component of benzene, toluene, and C-2 benzene. The percentage of green (chlorophyllous) leaves was useful as evidence of toxicity. The importance of anatomical features such as recessed meristem and abundant leaf sheaths in protecting the growing region from waterborne pollutants was evident.« less

  5. Patterns, structures and regulations of domestic water cycle systems in China

    NASA Astrophysics Data System (ADS)

    Chu, Junying; Wang, Hao; Wang, Jianhua; Qin, Dayong

    2010-05-01

    Domestic water cycle systems serving as one critical component of artificial water cycle at the catchment's scale, is so closely related to public healthy, human rights and social-economic development, and has gained the highest priority in strategic water resource and municipal infrastructure planning. In this paper, three basic patterns of domestic water cycle systems are identified and analyzed, including rural domestic water system (i.e. primary level), urban domestic water system (i.e. intermediate level) and metropolitan domestic water system (i.e. senior level), with different "abstract-transport-consume-discharge" mechanisms and micro-components of water consumption (such as drinking, cooking, toilet flushing, showering or cleaning). The rural domestic water system is general simple with three basic "abstract-consume-discharge" mechanisms and micro-components of basic water consumption such as drinking, cooking, washing and sanitation. The urban domestic water system has relative complex mechanisms of "abstract-supply-consume-treatment-discharge" and more micro-components of water consumption such as bath, dishwashing or car washing. The metropolitan domestic water system (i.e. senior level) has the most complex mechanisms by considering internal water reuse, external wastewater reclamation, and nutrient recycling processes. The detailed structures for different water cycle pattern are presented from the aspects of water quantity, wastewater quality and nutrients flow. With the speed up of urbanization and development of social-economy in China, those three basic patterns are interacting, transforming and upgrading. According to the past experiences and current situations, urban domestic water system (i.e. intermediate level) is the dominant pattern based on indicator of system number or system scale. The metropolitan domestic water system (i.e. senior level) is the idealized model for the future development and management. Current domestic water system management efforts typically fail in China, because the approach is generally narrowly-focused and fragmented. This paper put forward a total-process control framework following the water and pollutants (or nutrients) flows along the dualistic domestic water cycle process. Five key objectives of domestic water cycle system regulation are identified including water use safety, water use equity, water saving, wastewater reduction and nutrient recycling. Comprehensive regulatory framework regarding administrative, economic, technical and social measures is recommended to promote sustainable domestic water usage and demand management. Considering the relatively low affordability in rural area, economic measures should be mainly applied in urban domestic water systems and metropolitan domestic water systems. Engineering or technological measures which are suitable to the three domestic water cycle systems are discussed respectively.

  6. Lessons from Jerusalem.

    PubMed

    Daniell, Z

    1993-01-01

    The Gihon spring can no longer meet Jerusalem's water needs due to population growth. It provides just a small amount of water to an Arab community near Jerusalem called Silwan. 3 pipelines carry water to Jerusalem from coastal and mountain aquifers whose water tables are falling. A 4th pipeline is being built. Nevertheless, Jerusalem has been able to reduce water use, e.g. water use was lower in 1991 than in 1983, even though its population grew 25%. An engineer from the Department of Water attributed the reduced water use to conservation. The 1987 drought reduced the water in one of the city's main water sources, the Sea of Galilee, to very low levels. City authorities first responded by physically improving the water system, e.g., repairing system blow out valves and reducing water pressure where it was more than 60 m pressure. Next, the department distributed pamphlets on how to adjust household toilets to use less water per flush. The schools replaced all toilets with the new dual system. The city advertised water conservation in newspapers and buses. The department clamped down on industries and businesses using a disproportionate 23% of all water. In 1987. these efforts reduced water consumption 8-10%. A temporary law banned irrigation during the day when evaporation is greatest. The city charged residents more money for water used for gardening. Some residents have switched from grass laws to less thirsty local vegetation. The newness and efficiency of Jerusalem's pumping system and the commitment to replacing leaky pipes also contributes to the city's success. Jerusalem loses only about 10% of its water to leaks while other cities lose 40-60% of its water to leaks. Currently, the department partially subsidizes water-saving kits to be distributed to all households at a cost less than $4. 20% of households now use these kits. The department hopes to add another 40% of households. This holy city could be a water conservation model for all people.

  7. Soy germ extract alleviates menopausal hot flushes: placebo-controlled double-blind trial.

    PubMed

    Imhof, Martin; Gocan, Anca; Imhof, Marianne; Schmidt, Mathias

    2018-05-30

    A double-blind, placebo-controlled study was performed to assess the potency of a soy germ preparation for the alleviation of menopausal hot flushes. Caucasian women with at least seven hot flushes daily were treated with soy germ extract (100 mg isoflavone glycosides) daily or with placebo for 12 weeks, followed by 12 weeks of open treatment with soy. Outcome parameters were the number of hot flushes and the evaluation of the Greene Climacteric Scale. A total of 192 women were included. As the hot flush diaries from one study centre were lost, the assessment of hot flushes was based on 136 participants (soy: 54 women; placebo: 82 women). After 12 weeks, 180 women were available for the analysis of Greene Scale and safety (soy and placebo: each 90 women). Hot flushes were reduced by 43.3% (-3.5 hot flushes) with soy and by 30.8% with placebo (-2.6; p < 0.001). After the open treatment phase with soy, both original groups showed a reduction of 68% of hot flushes. A subgroup analysis showed better effects for soy when symptoms were classified as "severe" at baseline. After 12 weeks of double-blind treatment, there was an improvement from baseline values of 71 and 78% with soy with the items "hot flushes" and "sweating", compared with 24% for both items with placebo. Hormonal safety parameters remained uninfluenced. Soy germ extract with 100 mg of isoflavone glycosides was shown to modestly, but significantly reduce menopausal hot flushes.

  8. 'You know I've joined your club… I'm the hot flush boy': a qualitative exploration of hot flushes and night sweats in men undergoing androgen deprivation therapy for prostate cancer.

    PubMed

    Eziefula, C U; Grunfeld, E A; Hunter, M S

    2013-12-01

    Hot flushes and night sweats are common amongst menopausal women, and psychological interventions for managing these symptoms have recently been developed for women. However, flushes in men with prostate cancer, which commonly occur following androgen deprivation therapy (ADT), remain under-researched. This study is a qualitative exploration of flush-related cognitive appraisals and behavioural reactions reported by a sample of these men. Semi-structured, in-depth interviews were conducted with 19 men who were experiencing flushes after receiving ADT for prostate cancer. Framework analysis was used to generate and categorise emergent themes and explore associations between themes. Five main cognitive appraisals included the following: changes in oneself, impact on masculinity, embarrassment/social-evaluative concerns, perceived control and acceptance/adjustment. There were men who held beliefs about the impact of flushes on their perceptions of traditional gender roles, who experienced shame and embarrassment due to concerns about the salience of flushes and perceptions by others and who experienced feelings of powerlessness over flushes. Powerlessness was associated with beliefs about the potentially fatal consequences of discontinuing treatment. Two other dominant themes included awareness/knowledge about flushes and management strategies. Experiences of flushes appeared to be influenced by upbringing and general experiences of prostate cancer and ADT. The range of men's appraisals of, and reactions to, flushes generated from this qualitative exploration were broadly similar to those of menopausal women but differed in terms of the influence of masculinity beliefs. These findings could be used to inform future research and psychological interventions in this under-researched field. Copyright © 2013 John Wiley & Sons, Ltd.

  9. Effect of hypothermic pulmonary artery flushing on capillary filtration coefficient.

    PubMed

    Andrade, R S; Wangensteen, O D; Jo, J K; Tsai, M Y; Bolman, R M

    2000-07-27

    We previously demonstrated that surfactant dilution and inhibition occur immediately after pulmonary artery flushing with hypothermic modified Euro-Collins solution. Consequently, we speculated that increased capillary permeability contributed to these surfactant changes. To test this hypothesis, we evaluated the effects of hypothermic pulmonary artery flushing on the pulmonary capillary filtration coefficient (Kfc), and additionally performed a biochemical analysis of surfactant. We used a murine isolated, perfused lung model to measure the pulmonary capillary filtration coefficient and hemodynamic parameters, to determine the wet to dry weight ratio, and to evaluate surfactant by biochemical analysis of lung lavage fluid. We defined three study groups. In group I (controls), we harvested lungs without hypothermic pulmonary artery flushing, and measured Kfc immediately. In group II (in situ flush), we harvested lungs after hypothermic pulmonary artery flushing with modified Euro-Collins solution, and then measured Kfc. Experiments in groups I and II were designed to evaluate persistent changes in Kfc after pulmonary artery flushing. In group III (ex vivo flush), we flushed lungs ex vivo to evaluate transient changes in Kfc during hypothermic pulmonary artery flushing. Groups I and II did not differ significantly in capillary filtration coefficient and hemodynamics. Group II showed significant alterations on biochemical surfactant analysis and a significant increase in wet-to-dry weight ratio, when compared with group I. In group III, we observed a significant transient increase in capillary filtration coefficient during pulmonary artery flushing. Hypothermic pulmonary artery flushing transiently increases the capillary filtration coefficient, leads to an increase in the wet to dry weight ratio, and induces biochemical surfactant changes. These findings could be explained by the effects of hypothermic modified Euro-Collins solution on pulmonary capillary permeability.

  10. Decomposition behavior of hemicellulose and lignin in the step-change flow rate liquid hot water.

    PubMed

    Zhuang, Xinshu; Yu, Qiang; Wang, Wen; Qi, Wei; Wang, Qiong; Tan, Xuesong; Yuan, Zhenhong

    2012-09-01

    Hemicellulose and lignin are the main factors limiting accessibility of hydrolytic enzymes besides the crystallinity of cellulose. The decomposition behavior of hemicellulose and lignin in the step-change flow rate hot water system was investigated. Xylan removal increased from 64.53% for batch system (solid concentration 4.25% w/v, 18 min, 184°C) to 83.78% at high flow rates of 30 ml/min for 8 min, and then 10 ml/min for 10 min. Most of them (80-90%) were recovered as oligosaccharide. It was hypothesized that the flowing water could enhance the mass transfer to improve the sugars recovery. In addition, the solubilization mechanism of lignin in the liquid hot water was proposed according to the results of Fourier transform-infrared spectroscopy and scanning electron microscopy of the water-insoluble fraction and gas chromatography-mass spectrometry of the water-soluble fraction. It was proposed that lignin in the liquid hot water first migrated out of the cell wall in the form of molten bodies, and then flushed out of the reactor. A small quantity of them was further degraded into monomeric products such as vanillin, syringe aldehyde, coniferyl aldehyde, ferulic acid, and p-hydroxy-cinnamic acid. All of these observations would provide important information for the downstream processing, such as purification and concentration of sugars and the enzymatic digestion of residual solid.

  11. Modulation of magmatic processes by carbon dioxide

    NASA Astrophysics Data System (ADS)

    Caricchi, L.; Sheldrake, T. E.; Blundy, J. D.

    2017-12-01

    Volatile solubility in magmas increases with pressure, although the solubility of CO2 is much lower than that of H2O. Consequently, magmas rising from depth release CO2-rich fluids, which inevitably interact with H2O-poor magmas in the upper crust (CO2-flushing). CO2-flushing triggers the exsolution of H2O-rich fluids, leading to an increase of volume and magma crystallisation. While the analyses of eruptive products demonstrates that this process operates in virtually all magmatic system, its impact on magmatic and volcanic processes has not been quantified. Here we show that depending on the initial magma crystallinity, and the depth of magma storage, CO2-flushing can lead to volcanic eruptions or promote conditions that favour the impulsive release of mineralising fluids. Our calculations show that the interaction between a few hundred ppm of carbonic fluids, and crystal-poor magmas stored at shallow depths, produces rapid pressurisation that can potentially lead to an eruption. Further addition of CO2 increases magma compressibility and crystallinity, reducing the potential for volcanic activity, promoting the formation of ore deposits. Increasing the depth of fluid-magma interaction dampens the impact of CO2-flushing on the pressurisation of a magma reservoir. CO2-flushing may result in surface inflation and increases in surface CO2 fluxes, which are commonly considered signs of an impending eruption, but may not necessarily result in eruption depending on the initial crystallnity and depth of the magmatic reservoir. We propose that CO2-flushing is a powerful agent modulating the pressurisation of magma reservoirs and the release of mineralising fluids from upper crustal magma reservoirs.

  12. Enhanced Acquisition Rates of 'Candidatus Liberibacter asiaticus' by the Asian Citrus Psyllid (Hemiptera: Liviidae) in the Presence of Vegetative Flush Growth in Citrus.

    PubMed

    Sétamou, Mamoudou; Alabi, Olufemi J; Kunta, Madhurababu; Jifon, John L; da Graça, John V

    2016-10-01

    The Asian citrus psyllid preferentially feeds and exclusively reproduces on young, newly emerged flush shoots of citrus. Asian citrus psyllid nymphs feed and complete their life stages on these flush shoots. Recent studies conducted under greenhouse conditions have shown that the transmission rates of 'Candidatus Liberibacter asiaticus' (CLas), the putative causal agent of huanglongbing disease of citrus, are enhanced when flush shoots are present. However, it is unclear if CLas acquisition by migrant adult Asian citrus psyllids is similarly enhanced. To address this knowledge gap, cohorts of Asian citrus psyllid adults were allowed 1-wk acquisition access period (AAP) on flushing and nonflushing shoots of qPCR-tested symptomatic (CLas+) and asymptomatic (CLas-) 10-yr-old sweet orange trees under field conditions. After the AAP, they were tested for CLas by qPCR. Progeny Asian citrus psyllid adults that emerged 4 wk post-AAP were similarly retrieved and tested. Eighty percent of flushing and 30% of nonflushing CLas+ trees produced infective Asian citrus psyllid adults, indicating that flush shoots have greater potential to be inoculum sources for CLas acquisition. Concomitantly, 21.1% and 6.0% infective adults were retrieved, respectively, from flushing and nonflushing CLas+ trees, indicating that Asian citrus psyllid adults acquire CLas more efficiently from flush shoots relative to mature shoots. In addition, 12.1% of infective Asian citrus psyllid adult progeny were obtained from 70% of flushing CLas+ trees. Significantly lower mean Ct values were also obtained from infective adults retrieved from flushing relative to nonflushing trees. The results underscore the role of flush shoots in CLas acquisition and the need to protect citrus trees from Asian citrus psyllid infestations during flush cycles. © The Authors 2016. Published by Oxford University Press on behalf of Entomological Society of America. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  13. [Legionella spp. contamination in indoor air: preliminary results of an Italian multicenter study].

    PubMed

    Montagna, Maria Teresa; De Giglio, Osvalda; Napoli, Christian; Cannova, Lucia; Cristina, Maria Luisa; Deriu, Maria Grazia; Delia, Santi Antonino; Giuliano, Ada; Guida, Marco; Laganà, Pasqualina; Liguori, Giorgio; Mura, Ida; Pennino, Francesca; Rossini, Angelo; Tardivo, Stefano; Torre, Ida; Torregrossa, Maria Valeria; Villafrate, Maria Rosaria; Albertini, Roberto; Pasquarella, Cesira

    2014-01-01

    To propose a standardized protocol for the evaluation of Legionella contamination in air. A bathroom having a Legionella contamination in water >1,000 cfu/l was selected in 10 different healthcare facilities. Air contamination was assessed by active (Surface Air System, SAS) and passive (Index of Microbial Air, IMA) sampling for 8 hours, about 1 m away from the floor and 50 cm from the tap water. Two hundred liters of air were sampled by SAS every 12 min, after flushing water for 2 min. The IMA value was calculated as the mean value of colony forming units/16 plates exposed during sampling (2 plates/hour). Water contamination was evaluated at T0, after 4 and 8 hours, according to the standard methods. Air contamination by Legionella was found in three healthcare facilities (one with active and two with passive sampling), showing a concomitant tap water contamination (median=40,000; range 1,100-43,000 cfu/l). The remaining seven hospitals isolated Legionella spp. exclusively from water samples (median=8,000; range 1,200-70,000 cfu/l). Our data suggest that environmental Legionella contamination cannot be assessed only through the air sampling, even in the presence of an important water contamination.

  14. Microbiological tap water profile of a medium-sized building and effect of water stagnation.

    PubMed

    Lipphaus, Patrick; Hammes, Frederik; Kötzsch, Stefan; Green, James; Gillespie, Simon; Nocker, Andreas

    2014-01-01

    Whereas microbiological quality of drinking water in water distribution systems is routinely monitored for reasons of legal compliance, microbial numbers in tap water are grossly understudied. Motivated by gross differences in water from private households, we applied in this study flow cytometry as a rapid analytical method to quantify microbial concentrations in water sampled at diverse taps in a medium size research building receiving chlorinated water. Taps differed considerably in frequency of usage and were located in laboratories, bathrooms, and a coffee kitchen. Substantial differences were observed between taps with concentrations (per mL) in the range from 6.29 x 10(3) to 7.74 x 10(5) for total cells and from 1.66 x 10(3) to 4.31 x 10(5) for intact cells. The percentage of intact cells varied between 7% and 96%. Water from taps with very infrequent use showed the highest bacterial numbers and the highest proportions of intact cells. Stagnation tended to increase microbial numbers in water from those taps which were otherwise frequently used. Microbial numbers in other taps that were rarely opened were not affected by stagnation as their water is probably mostly stagnant. For cold water taps, microbial numbers and the percentage of intact cells tended to decline with flushing with the greatest decline for taps used least frequently whereas microbial concentrations in water from hot water taps tended to be somewhat more stable. We conclude that microbiological water quality is mainly determined by building-specific parameters. Tap water profiling can provide valuable insight into plumbing system hygiene and maintenance.

  15. Tests Of Array Of Flush Pressure Sensors

    NASA Technical Reports Server (NTRS)

    Larson, Larry J.; Moes, Timothy R.; Siemers, Paul M., III

    1992-01-01

    Report describes tests of array of pressure sensors connected to small orifices flush with surface of 1/7-scale model of F-14 airplane in wind tunnel. Part of effort to determine whether pressure parameters consisting of various sums, differences, and ratios of measured pressures used to compute accurately free-stream values of stagnation pressure, static pressure, angle of attack, angle of sideslip, and mach number. Such arrays of sensors and associated processing circuitry integrated into advanced aircraft as parts of flight-monitoring and -controlling systems.

  16. Column Testing and 1D Reactive Transport Modeling to Evaluate Uranium Plume Persistence Processes

    NASA Astrophysics Data System (ADS)

    Johnson, R. H.; Morrison, S.; Morris, S.; Tigar, A.; Dam, W. L.; Dayvault, J.

    2015-12-01

    At many U.S. Department of Energy Office of Legacy Management sites, 100 year natural flushing was selected as a remedial option for groundwater uranium plumes. However, current data indicate that natural flushing is not occurring as quickly as expected and solid-phase and aqueous uranium concentrations are persistent. At the Grand Junction, Colorado office site, column testing was completed on core collected below an area where uranium mill tailings have been removed. The total uranium concentration in this core was 13.2 mg/kg and the column was flushed with laboratory-created water with no uranium and chemistry similar to the nearby Gunnison River. The core was flushed for a total of 91 pore volumes producing a maximum effluent uranium concentration of 6,110 μg/L at 2.1 pore volumes and a minimum uranium concentration of 36.2 μg/L at the final pore volume. These results indicate complex geochemical reactions at small pore volumes and a long tailing affect at greater pore volumes. Stop flow data indicate the occurrence of non-equilibrium processes that create uranium concentration rebound. These data confirm the potential for plume persistence, which is occurring at the field scale. 1D reactive transport modeling was completed using PHREEQC (geochemical model) and calibrated to the column test data manually and using PEST (inverse modeling calibration routine). Processes of sorption, dual porosity with diffusion, mineral dissolution, dispersion, and cation exchange were evaluated separately and in combination. The calibration results indicate that sorption and dual porosity are major processes in explaining the column test data. These processes are also supported by fission track photographs that show solid-phase uranium residing in less mobile pore spaces. These procedures provide valuable information on plume persistence and secondary source processes that may be used to better inform and evaluate remedial strategies, including natural flushing.

  17. Recent sheath physics studies on DIII-D

    NASA Astrophysics Data System (ADS)

    Watkins, J. G.; Labombard, B.; Stangeby, P. C.; Lasnier, C. J.; McLean, A. G.; Nygren, R. E.; Boedo, J. A.; Leonard, A. W.; Rudakov, D. L.

    2015-08-01

    A study to examine some current issues in the physics of the plasma sheath has been recently carried out in DIII-D low power Ohmic plasmas using both flush and domed Langmuir probes, divertor Thomson scattering (DTS), an infrared camera (IRTV), and a new calorimeter triple probe assembly mounted on the Divertor Materials Evaluation System (DIMES). The sheath power transmission factor was found to be consistent with the theoretically predicted value of 7 (±2) for low power plasmas. Using this factor, the three heat flux profiles derived from the LP, DTS, and calorimeter diagnostic measurements agree. Comparison of flush and domed Langmuir probes and divertor Thomson scattering indicates that proper interpretation of flush probe data to get target plate density and temperature is feasible and could potentially yield accurate measurements of target plate conditions where the probes are located.

  18. Aspirin attenuation of alcohol-induced flushing and intoxication in Oriental and Occidental subjects.

    PubMed

    Truitt, E B; Gaynor, C R; Mehl, D L

    1987-01-01

    Aspirin (ASA) was tested in a group of 8 Oriental and 3 Occidental subjects who were shown in a previous study to respond to small doses of ethanol (0.06-0.25 g/kg) with facial flushing. They were compared to a similar group of 11 non-flushing Occidental subjects following a larger ethanol dose (0.37 g/kg) to determine if similar effects could be produced in less sensitive individuals. Control tests of blood ethanol and acetaldehyde (AcH) levels (calculated from breath), facial and neck skin temperatures, body sway (Romberg test), blood pressure, heart rate and 10 Subjective High Assessment Scales (SHAS-Judd, 1977) were conducted before and at 15, 30, 60 and 90 minutes after drinking ethanol as vodka in orange juice. The tests were repeated one week later one hour after receiving 0.64 gm of ASA orally. ASA produced slight changes in the early absorption of ethanol and small decreases in AcH levels in the flushing and non-flushing groups. Facial flushing was markedly reduced in the flushing group, but was slightly increased in the non-flushing Occidentals. Body sway was reduced by ASA in both groups. An alcohol-induced increase in heart rate in the flushing group was reduced with no change in blood pressure. SHAS subjective parameters were widely variable, but indicated that ASA produced reduced sleepiness and earlier relaxation in the flushing group. It is concluded that ASA can block alcohol-induced facial flushing in sensitive subjects and also reduces body sway in the Romberg test and alters some subjective feelings of alcohol intoxication.

  19. Efficacy of Various Chemical Disinfectants on Biofilms Formed in Spacecraft Potable Water System Component

    NASA Technical Reports Server (NTRS)

    Wong, Willy; Garcia, Veronica; Castro, Victoria; Ott, Mark; Duane

    2009-01-01

    As the provision of potable water is critical for successful habitation of the International Space Station (ISS), life support systems were installed in December 2008 to recycle both humidity from the atmosphere and urine to conserve available water in the vehicle. Pre-consumption testing from the dispensing needle at the Potable Water Dispenser (PWD) indicated that bacterial concentrations exceeded the current ISS specifications of 50 colony forming units (CFU) per ml. Subsequent investigations revealed that a corrugated stainless steel flex hose upstream of the dispensing needle in the PWD was filled with non-sterile water and left at room temperature for over one month before launch. To simulate biofilm formation that was suspected in the flight system, sterile flex hoses were seeded with a consortium of bacterial isolates previously recovered from other ISS water systems, which included Ralstonia pickettii, Burkholderia multivorans, Caulobacter vibrioides., and Cupriavidus pauculus. After 5 days of incubation, these hoses were challenged with various chemical disinfectants including hydrogen peroxide, colloidal silver, and buffered pH solutions to determine the ability of the disinfectants to decrease and maintain bacterial concentrations below ISS specifications. Disinfection efficacy over time was measured by collecting daily heterotrophic plate counts following exposure to the disinfectants. A single flush with either 6% hydrogen peroxide solution or a mixture of 3% hydrogen peroxide and 400 ppb colloidal silver effectively reduced the bacterial concentrations to less than 1 CFU/ml for a period of up to 2 months. Testing results indicated that hydrogen peroxide and mixtures of hydrogen peroxide and colloidal silver have tremendous potential as alternative disinfectants for ISS water systems.

  20. Assessing the Impact of Topography on Groundwater Salinization Due to Storm Surge Inundation

    NASA Astrophysics Data System (ADS)

    Yu, X.; Yang, J.; Graf, T.; Koneshloo, M.; O'Neal, M. A.; Michael, H. A.

    2015-12-01

    The sea-level rise and increase in the frequency and intensity of coastal storms due to climate change are likely to exacerbate adverse effects of storm surges on low-lying coastal areas. The landward flow of water during storm surges introduces salt to surficial coastal aquifers and threatens groundwater resources. Coastal topography (e.g. ponds, dunes, canals) likely has a strong impact on overwash and salinization processes, but is generally highly simplified in modeling studies. To understand the topographic impacts on groundwater salinization, we modeled overwash and variable-density groundwater flow and salt transport in 3D using the fully coupled surface and subsurface numerical simulator, HydroGeoSphere. The model simulates the coastal aquifer as an integrated system considering processes such as overland flow, coupled surface and subsurface exchange, variably saturated flow, and variable-density flow. To represent various coastal landscape types, we started with realistic coastal topography from Delaware, USA, and then generated synthetic fields with differing shore-perpendicular connectivity and surface depressions. The groundwater salinization analysis suggested that the topographic connectivity promoting overland flow controls the volume of aquifer that is salinized. In contrast, depression storage of surface water mainly controls the time for infiltrated salt to flush from the aquifer. The results indicate that for a range of synthetic conditions, topography increases the flushing time of salt by 20-300% relative to an equivalent "simple slope" in which topographic variation is absent. Our study suggests that topography have a significant impact on overwash salinization, with important implications for land management at local scales and groundwater vulnerability assessment at regional to global scales.

Top