Variable-Volume Flushing (V-VF) device for water conservation in toilets
NASA Technical Reports Server (NTRS)
Jasper, Louis J., Jr.
1993-01-01
Thirty five percent of residential indoor water used is flushed down the toilet. Five out of six flushes are for liquid waste only, which requires only a fraction of the water needed for solid waste. Designers of current low-flush toilets (3.5-gal. flush) and ultra-low-flush toilets (1.5-gal. flush) did not consider the vastly reduced amount of water needed to flush liquid waste versus solid waste. Consequently, these toilets are less practical than desired and can be improved upon for water conservation. This paper describes a variable-volume flushing (V-VF) device that is more reliable than the currently used flushing devices (it will not leak), is simple, more economical, and more water conserving (allowing one to choose the amount of water to use for flushing solid and liquid waste).
The educational potential of alcohol-related flushing among Chinese young people
Shell, Duane F.; Huang, Zhaoqing; Qian, Ling
2015-01-01
Aim: This paper describes Chinese university students' understanding of the meaning of the alcohol-related flushing response and how they reacted to their own and someone else's flushing in a group drinking situation. Method: The researcher surveyed 530 Chinese university students about their understanding of flushing and their perception of how people respond to a person who visibly flushes while drinking alcohol. Findings: Most students did not know about the physiological cause of flushing. There were significant gender differences in both reactions to and perception of responses to a person who flushes. There was no direct relationship between flushing and drinking behaviour. Conclusions: This description of flushing behaviour and responses to a flushing person is discussed in terms of educational opportunities to change behaviours that could reduce the cancer related risks of this visibly at-risk group. PMID:25983401
Holm, Anna-Clara Spetz; Thorell, Lars-Håkan; Theodorsson, Elvar; Hammar, Mats
2012-01-01
Calcitonin gene-related peptide (CGRP) seems to be involved in hot flushes in women and in castrated men. Therefore, we studied whether the plasma concentrations of CGRP changed during flushes in a group of healthy aging men. Twelve men (49-71 years) with no history of current or former prostate cancer or hormonal treatment reporting ≥ 20 flushes/week were investigated. Blood samples were drawn during and between flushes for analysis of CGRP and also androgen concentrations, that is, testosterone and bioavailable testosterone were analysed. Skin temperature and skin conductance were monitored. Thirty-five flushes were reported by 10 men. The plasma concentrations of CGRP did not increase during flushes. No significant change in skin temperature or conductance was found. CGRP is probably not involved in the mechanisms of flushes in healthy aging men. Therefore, flushes in aging healthy men seem to be different from flushes in men and women deprived of sex steroids where CGRP increases during flushes.
33 CFR 162.20 - Flushing Bay near La Guardia Airport, Flushing, N.Y.; restricted area.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Flushing Bay near La Guardia Airport, Flushing, N.Y.; restricted area. 162.20 Section 162.20 Navigation and Navigable Waters COAST... NAVIGATION REGULATIONS § 162.20 Flushing Bay near La Guardia Airport, Flushing, N.Y.; restricted area. (a...
Hormonal control of second flushing in Douglas-fir shoots.
Morris Cline; Mark Yoders; Dipti Desai; Constance Harrington; William Carlson
2006-01-01
Spring-flushing, over-wintered buds of Douglas-fir (Pseudotsuga menziesii (Mirb.) Franco) produce new buds that may follow various developmental pathways. These include second flushing in early summer or dormancy before flushing during the following spring. Second flushing usually entails an initial release of apical dominance as some of the...
Yan, Xiulan; Liu, Qiuxin; Wang, Jianyi; Liao, Xiaoyong
2017-07-01
Phytoremediation and soil washing are both potentially useful for remediating arsenic (As)-contaminated soils. We evaluated the effectiveness of a combined process coupling phytoremediation and in situ soil flushing for removal of As in contaminated soil through a pilot study. The results showed that growing Pteris vittata L. (P.v.) accompanied by soil flushing of phosphate (P.v./Flushing treatment) could significantly decrease the total As concentration of soil over a 37day flushing period compared with the single flushing (Flushing treatment). The P.v./Flushing treatment removed 54.04% of soil As from contaminated soil compared to 47.16% in Flushing treatment, suggesting that the growth of P. vittata was beneficial for promoting the removal efficiency. We analyzed the As fractionation in soil and As concentration in soil solution to reveal the mechanism behind this combined process. Results showed that comparing with the control treatment, the percent of labile arsenate fraction significantly increased by 17% under P.v./Flushing treatment. As concentration in soil solution remained a high lever during the middle and later periods (51.26-56.22mg/L), which was significantly higher than the Flushing treatment. Although soil flushing of phosphate for more than a month, P. vittata still had good accumulation and transfer capacity of As of the soil. The results of the research revealed that combination of phytoremediation and in situ soil flushing is available to remediate As-contaminated soils. Copyright © 2016. Published by Elsevier B.V.
Ohara, Yoshiko; Toyonaga, Takashi; Hoshi, Namiko; Tanaka, Shinwa; Baba, Shinichi; Takihara, Hiroshi; Kawara, Fumiaki; Ishida, Tsukasa; Morita, Yoshinori; Umegaki, Eiji; Azuma, Takeshi
2017-03-07
To investigated the usefulness of a novel slim type ball-tipped FlushKnife (FlushKnife-BTS) over ball-tipped FlushKnife (FlushKnife-BT) in functional experiments and clinical practice. In order to evaluate the functionality of FlushKnife-BTS, water aspiration speed, resistance to knife insertion through the scope, and waterjet flushing speed were compared between FlushKnife-BTS and BT. In clinical practice, esophageal endoscopic submucosal dissection (ESD) performed using FlushKnife-BTS or BT by an experienced endoscopist between October 2015 and January 2016 were retrospectively reviewed. The treatment speed and frequency of removing and reinserting the knife to aspirate fluid and air during ESD sessions were analyzed. Functional experiments revealed that water aspiration speed by the endoscope equipped with a 2.8-mm working channel with FlushKnife-BTS was 7.7-fold faster than that with conventional FlushKnife-BT. Resistance to knife insertion inside the scope with a 2.8-mm working channel was reduced by 40% with FlushKnife-BTS. The waterjet flushing speed was faster with the use of FlushKnife-BT. In clinical practice, a comparison of 6 and 7 ESD using FlushKnife-BT and BTS, respectively, revealed that the median treatment speed was 25.5 mm 2 /min (range 19.6-30.3) in the BT group and 44.2 mm 2 /min (range 15.5-55.4) in the BTS group ( P = 0.0633). However, the median treatment speed was significantly faster with FlushKnife-BTS when the resection size was larger than 1000 m 2 ( n = 4, median 24.2 mm 2 /min, range 19.6-27.7 vs n = 4, median 47.4 mm 2 /min, range 44.2-55.4, P = 0.0209). The frequency of knife replacement was less in the BTS group (median 1.76 times in one hour, range 0-5.45) than in the BT group (7.02 times in one hour, range 4.23-15) ( P = 0.0065). Our results indicate that FlushKnife-BTS enhances the performance of ESD, particularly for large lesions, by improving air and fluid aspiration and knife insertion during ESD and reducing the frequency of knife removal and reinsertion.
Ohara, Yoshiko; Toyonaga, Takashi; Hoshi, Namiko; Tanaka, Shinwa; Baba, Shinichi; Takihara, Hiroshi; Kawara, Fumiaki; Ishida, Tsukasa; Morita, Yoshinori; Umegaki, Eiji; Azuma, Takeshi
2017-01-01
AIM To investigated the usefulness of a novel slim type ball-tipped FlushKnife (FlushKnife-BTS) over ball-tipped FlushKnife (FlushKnife-BT) in functional experiments and clinical practice. METHODS In order to evaluate the functionality of FlushKnife-BTS, water aspiration speed, resistance to knife insertion through the scope, and waterjet flushing speed were compared between FlushKnife-BTS and BT. In clinical practice, esophageal endoscopic submucosal dissection (ESD) performed using FlushKnife-BTS or BT by an experienced endoscopist between October 2015 and January 2016 were retrospectively reviewed. The treatment speed and frequency of removing and reinserting the knife to aspirate fluid and air during ESD sessions were analyzed. RESULTS Functional experiments revealed that water aspiration speed by the endoscope equipped with a 2.8-mm working channel with FlushKnife-BTS was 7.7-fold faster than that with conventional FlushKnife-BT. Resistance to knife insertion inside the scope with a 2.8-mm working channel was reduced by 40% with FlushKnife-BTS. The waterjet flushing speed was faster with the use of FlushKnife-BT. In clinical practice, a comparison of 6 and 7 ESD using FlushKnife-BT and BTS, respectively, revealed that the median treatment speed was 25.5 mm2/min (range 19.6-30.3) in the BT group and 44.2 mm2/min (range 15.5-55.4) in the BTS group (P = 0.0633). However, the median treatment speed was significantly faster with FlushKnife-BTS when the resection size was larger than 1000 m2 (n = 4, median 24.2 mm2/min, range 19.6-27.7 vs n = 4, median 47.4 mm2/min, range 44.2-55.4, P = 0.0209). The frequency of knife replacement was less in the BTS group (median 1.76 times in one hour, range 0-5.45) than in the BT group (7.02 times in one hour, range 4.23-15) (P = 0.0065). CONCLUSION Our results indicate that FlushKnife-BTS enhances the performance of ESD, particularly for large lesions, by improving air and fluid aspiration and knife insertion during ESD and reducing the frequency of knife removal and reinsertion. PMID:28321167
NASA Astrophysics Data System (ADS)
Wang, Xingwei; Chen, Jiajun
2017-06-01
With an aim to investigate the influence of small-scale interlayer heterogeneity on DDT removal efficiency, batch test including surfactant-stabilized foam flushing and solution flushing were carried out. Two man-made heterogeneous patterns consisting of coarse and fine quartz sand were designed to reveal the influencing mechanism. Moreover, the removal mechanism and the corresponding contribution by foam flushing were quantitatively studied. Compared with surfactant solution flushing, the DDT removal efficiency by surfactant-stabilized foam flushing increased by 9.47% and 11.28% under heterogeneous patterns 1 and 2, respectively. The DDT removal contributions of improving sweep efficiency for heterogeneous patterns 1 and 2 by foam flushing were 40.82% and 45.98%, and the contribution of dissolving capacity were 59.18% and 54.02%, respectively. The dissolving capacity of DDT played a major role in DDT removal efficiency by foam flushing under laboratory conditions. And the DDT removal contribution of significant improving sweep efficiency was higher than that of removal decline caused by weak solubilizing ability of foam film compared with solution flushing. The obtained results indicated that the difference of DDT removal efficiency by foam flushing was decreased under two different heterogeneous patterns with the increase of the contribution of improving foam flushing sweep efficiency. It suggested that foam flushing can reduce the disturbance from interlayer heterogeneity in remediating DDT contaminated heterogeneous medium.
33 CFR 162.20 - Flushing Bay near La Guardia Airport, Flushing, N.Y.; restricted area.
Code of Federal Regulations, 2013 CFR
2013-07-01
... Airport, Flushing, N.Y.; restricted area. 162.20 Section 162.20 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PORTS AND WATERWAYS SAFETY INLAND WATERWAYS NAVIGATION REGULATIONS § 162.20 Flushing Bay near La Guardia Airport, Flushing, N.Y.; restricted area. (a...
33 CFR 162.20 - Flushing Bay near La Guardia Airport, Flushing, N.Y.; restricted area.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Airport, Flushing, N.Y.; restricted area. 162.20 Section 162.20 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PORTS AND WATERWAYS SAFETY INLAND WATERWAYS NAVIGATION REGULATIONS § 162.20 Flushing Bay near La Guardia Airport, Flushing, N.Y.; restricted area. (a...
Morphology and Length Correlated in Terminal Flushes of Longleaf Pine Saplings
R.M. Allen; N.M. Scarbrough
1970-01-01
In longleafpine (Pinuspalustris Mill.) saplings growing in southern Mississippi the length of the first or spring flush was significantly correlated with that of the second flush; the correlation of length between flushes two and three was also statistically significant. The correlations were due more to similarities in internode elongation than to node number. Flush...
Wang, Xingwei; Chen, Jiajun
2017-06-01
With an aim to investigate the influence of small-scale interlayer heterogeneity on DDT removal efficiency, batch test including surfactant-stabilized foam flushing and solution flushing were carried out. Two man-made heterogeneous patterns consisting of coarse and fine quartz sand were designed to reveal the influencing mechanism. Moreover, the removal mechanism and the corresponding contribution by foam flushing were quantitatively studied. Compared with surfactant solution flushing, the DDT removal efficiency by surfactant-stabilized foam flushing increased by 9.47% and 11.28% under heterogeneous patterns 1 and 2, respectively. The DDT removal contributions of improving sweep efficiency for heterogeneous patterns 1 and 2 by foam flushing were 40.82% and 45.98%, and the contribution of dissolving capacity were 59.18% and 54.02%, respectively. The dissolving capacity of DDT played a major role in DDT removal efficiency by foam flushing under laboratory conditions. And the DDT removal contribution of significant improving sweep efficiency was higher than that of removal decline caused by weak solubilizing ability of foam film compared with solution flushing. The obtained results indicated that the difference of DDT removal efficiency by foam flushing was decreased under two different heterogeneous patterns with the increase of the contribution of improving foam flushing sweep efficiency. It suggested that foam flushing can reduce the disturbance from interlayer heterogeneity in remediating DDT contaminated heterogeneous medium. Copyright © 2017 Elsevier B.V. All rights reserved.
Hot flushes, coronary heart disease, and hormone therapy in postmenopausal women
Huang, Alison J.; Sawaya, George F.; Vittinghoff, Eric; Lin, Feng; Grady, Deborah
2010-01-01
Objective The aim of this study was to examine interactions between hot flushes, estrogen plus progestogen therapy (EPT), and coronary heart disease (CHD) events in postmenopausal women with CHD. Methods We analyzed data from the Heart and Estrogen/Progestin Replacement Study, a randomized, placebo-controlled trial of 0.625 mg conjugated equine estrogens plus 2.5 mg medroxyprogesterone acetate in 2,763 postmenopausal women with CHD. Hot flushes were assessed at baseline using self-administered questionnaires; women reporting bothersome hot flushes “some” to ”all” of the time were considered to have clinically significant flushing. Cox regression models were used to examine the effect of EPT on risk of CHD events among women with and without significant flushing at baseline. Results The mean age of participants was 66.7 ± 6.8 years, and 89% (n = 2,448) were white. Sixteen percent (n = 434) of participants reported clinically significant hot flushes at baseline. Among women with baseline flushing, EPT increased risk of CHD events nine-fold in the first year compared with placebo (hazard ratio = 9.01; 95% CI, 1.15-70.35); among women without baseline flushing, treatment did not significantly affect CHD event risk in the first year (hazard ratio = 1.32; 95% CI, 0.86-2.03; P = 0.07 for interaction of hot flushes with treatment). The trend toward differential effects of EPT on risk for CHD among women with and without baseline flushing did not persist after the first year of treatment. Conclusions Among older postmenopausal women with CHD, EPT may increase risk of CHD events substantially in the first year of treatment among women with clinically significant hot flushes but not among those without hot flushes. PMID:19325499
Influence of headspace flushing on methane production in Biochemical Methane Potential (BMP) tests.
Koch, Konrad; Bajón Fernández, Yadira; Drewes, Jörg E
2015-06-01
The influence of headspace flushing on the specific methane (CH4) production of blank samples with just inoculum in Biochemical Methane Potential (BMP) tests was studied. The three most common ways were applied: flushing with nitrogen (N2) gas, flushing with a mixture of N2 and CO2 (80/20 v/v), and no flushing. The results revealed that removing the oxygen is crucial to avoid aerobic respiration, which caused both hindered activity of methanogens and loss of methane potential. Furthermore it was demonstrated that 20% of CO2 in the flush gas increased significantly the methane production by over 20% compared to the flushing with pure N2. In order to mimic the same headspace conditions as in full-scale treatment plants, using a flush gas with a similar CO2 concentration as the expected biogas is suggested. Copyright © 2015 Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hanson, P.J.; Isebrands, J.G.; Dickson, R.E.
1988-03-01
Carbon dioxide exchange rates (CERs) of all leaves along the stem of northern red oak (Quercus rubra L.) seedlings (a leaf insertion gradient of profile) were determined at several stages of ontogeny. Seedlings were grown and measured under growth chamber conditions favorable for the production of multiple flushes of shoot growth. The CERs were measured with a portable closed-circuit CO{sub 2} analyzer at ambient photosynthetic photon flux densities and were determined for every leaf of each seedling. Carbon dioxide exchange rates per unit projected area of individual leaves (CERA) increased along leaf-maturation gradients in expanding flushes. After flush growth wasmore » completed, all leaves of a flush has similar CERA. However, because median flush leaves were the largest, they accounted for the greatest proportion of an expanded-flush's CER. First-flush leaves were the major contributors to total seedling CER through the second flush of growth-encompassing half of the period required to produce a three-flush oak seedling. This study's data, based on short-term CER measurements, showed ontogenetic pattern of CO{sub 2} exchange similar to those reported for northern red oak under steady state laboratory conditions.« less
Exercise training reduces the acute physiological severity of post‐menopausal hot flushes
Bailey, Tom G.; Cable, N. Timothy; Aziz, Nabil; Atkinson, Greg; Cuthbertson, Daniel J.; Low, David A.
2016-01-01
Key points A post‐menopausal hot flush consists of profuse physiological elevations in cutaneous vasodilatation and sweating that are accompanied by reduced brain blood flow. These responses can be used to objectively quantify hot flush severity.The impact of an exercise training intervention on the physiological responses occurring during a hot flush is currently unknown.In a preference‐controlled trial involving 21 post‐menopausal women, 16 weeks of supervised moderate intensity exercise training was found to improve cardiorespiratory fitness and attenuate cutaneous vasodilatation, sweating and the reductions in cerebral blood flow during a hot flush.It is concluded that the improvements in fitness that are mediated by 16 weeks of exercise training reduce the severity of physiological symptoms that occur during a post‐menopausal hot flush. Abstract A hot flush is characterised by feelings of intense heat, profuse elevations in cutaneous vasodilatation and sweating, and reduced brain blood flow. Exercise training reduces self‐reported hot flush severity, but underpinning physiological data are lacking. We hypothesised that exercise training attenuates the changes in cutaneous vasodilatation, sweat rate and cerebral blood flow during a hot flush. In a preference trial, 18 symptomatic post‐menopausal women underwent a passive heat stress to induce hot flushes at baseline and follow‐up. Fourteen participants opted for a 16 week moderate intensity supervised exercise intervention, while seven participants opted for control. Sweat rate, cutaneous vasodilatation, blood pressure, heart rate and middle cerebral artery velocity (MCAv) were measured during the hot flushes. Data were binned into eight equal segments, each representing 12.5% of hot flush duration. Weekly self‐reported frequency and severity of hot flushes were also recorded at baseline and follow‐up. Following training, mean hot flush sweat rate decreased by 0.04 mg cm2 min−1 at the chest (95% confidence interval 0.02–0.06, P = 0.01) and by 0.03 mg cm2 min−1 (0.02–0.05, P = 0.03) at the forearm, compared with negligible changes in control. Training also mediated reductions in cutaneous vasodilatation by 9% (6–12%) at the chest and by 7% (4–9%) at forearm (P ≤ 0.05). Training attenuated hot flush MCAv by 3.4 cm s−1 (0.7–5.1 cm s−1, P = 0.04) compared with negligible changes in control. Exercise training reduced the self‐reported severity of hot flushes by 109 arbitrary units (80–121, P < 0.001). These data indicate that exercise training leads to parallel reductions in hot flush severity and within‐flush changes in cutaneous vasodilatation, sweating and cerebral blood flow. PMID:26676059
Soy germ extract alleviates menopausal hot flushes: placebo-controlled double-blind trial.
Imhof, Martin; Gocan, Anca; Imhof, Marianne; Schmidt, Mathias
2018-05-30
A double-blind, placebo-controlled study was performed to assess the potency of a soy germ preparation for the alleviation of menopausal hot flushes. Caucasian women with at least seven hot flushes daily were treated with soy germ extract (100 mg isoflavone glycosides) daily or with placebo for 12 weeks, followed by 12 weeks of open treatment with soy. Outcome parameters were the number of hot flushes and the evaluation of the Greene Climacteric Scale. A total of 192 women were included. As the hot flush diaries from one study centre were lost, the assessment of hot flushes was based on 136 participants (soy: 54 women; placebo: 82 women). After 12 weeks, 180 women were available for the analysis of Greene Scale and safety (soy and placebo: each 90 women). Hot flushes were reduced by 43.3% (-3.5 hot flushes) with soy and by 30.8% with placebo (-2.6; p < 0.001). After the open treatment phase with soy, both original groups showed a reduction of 68% of hot flushes. A subgroup analysis showed better effects for soy when symptoms were classified as "severe" at baseline. After 12 weeks of double-blind treatment, there was an improvement from baseline values of 71 and 78% with soy with the items "hot flushes" and "sweating", compared with 24% for both items with placebo. Hormonal safety parameters remained uninfluenced. Soy germ extract with 100 mg of isoflavone glycosides was shown to modestly, but significantly reduce menopausal hot flushes.
Eziefula, C U; Grunfeld, E A; Hunter, M S
2013-12-01
Hot flushes and night sweats are common amongst menopausal women, and psychological interventions for managing these symptoms have recently been developed for women. However, flushes in men with prostate cancer, which commonly occur following androgen deprivation therapy (ADT), remain under-researched. This study is a qualitative exploration of flush-related cognitive appraisals and behavioural reactions reported by a sample of these men. Semi-structured, in-depth interviews were conducted with 19 men who were experiencing flushes after receiving ADT for prostate cancer. Framework analysis was used to generate and categorise emergent themes and explore associations between themes. Five main cognitive appraisals included the following: changes in oneself, impact on masculinity, embarrassment/social-evaluative concerns, perceived control and acceptance/adjustment. There were men who held beliefs about the impact of flushes on their perceptions of traditional gender roles, who experienced shame and embarrassment due to concerns about the salience of flushes and perceptions by others and who experienced feelings of powerlessness over flushes. Powerlessness was associated with beliefs about the potentially fatal consequences of discontinuing treatment. Two other dominant themes included awareness/knowledge about flushes and management strategies. Experiences of flushes appeared to be influenced by upbringing and general experiences of prostate cancer and ADT. The range of men's appraisals of, and reactions to, flushes generated from this qualitative exploration were broadly similar to those of menopausal women but differed in terms of the influence of masculinity beliefs. These findings could be used to inform future research and psychological interventions in this under-researched field. Copyright © 2013 John Wiley & Sons, Ltd.
Effect of hypothermic pulmonary artery flushing on capillary filtration coefficient.
Andrade, R S; Wangensteen, O D; Jo, J K; Tsai, M Y; Bolman, R M
2000-07-27
We previously demonstrated that surfactant dilution and inhibition occur immediately after pulmonary artery flushing with hypothermic modified Euro-Collins solution. Consequently, we speculated that increased capillary permeability contributed to these surfactant changes. To test this hypothesis, we evaluated the effects of hypothermic pulmonary artery flushing on the pulmonary capillary filtration coefficient (Kfc), and additionally performed a biochemical analysis of surfactant. We used a murine isolated, perfused lung model to measure the pulmonary capillary filtration coefficient and hemodynamic parameters, to determine the wet to dry weight ratio, and to evaluate surfactant by biochemical analysis of lung lavage fluid. We defined three study groups. In group I (controls), we harvested lungs without hypothermic pulmonary artery flushing, and measured Kfc immediately. In group II (in situ flush), we harvested lungs after hypothermic pulmonary artery flushing with modified Euro-Collins solution, and then measured Kfc. Experiments in groups I and II were designed to evaluate persistent changes in Kfc after pulmonary artery flushing. In group III (ex vivo flush), we flushed lungs ex vivo to evaluate transient changes in Kfc during hypothermic pulmonary artery flushing. Groups I and II did not differ significantly in capillary filtration coefficient and hemodynamics. Group II showed significant alterations on biochemical surfactant analysis and a significant increase in wet-to-dry weight ratio, when compared with group I. In group III, we observed a significant transient increase in capillary filtration coefficient during pulmonary artery flushing. Hypothermic pulmonary artery flushing transiently increases the capillary filtration coefficient, leads to an increase in the wet to dry weight ratio, and induces biochemical surfactant changes. These findings could be explained by the effects of hypothermic modified Euro-Collins solution on pulmonary capillary permeability.
Sétamou, Mamoudou; Alabi, Olufemi J; Kunta, Madhurababu; Jifon, John L; da Graça, John V
2016-10-01
The Asian citrus psyllid preferentially feeds and exclusively reproduces on young, newly emerged flush shoots of citrus. Asian citrus psyllid nymphs feed and complete their life stages on these flush shoots. Recent studies conducted under greenhouse conditions have shown that the transmission rates of 'Candidatus Liberibacter asiaticus' (CLas), the putative causal agent of huanglongbing disease of citrus, are enhanced when flush shoots are present. However, it is unclear if CLas acquisition by migrant adult Asian citrus psyllids is similarly enhanced. To address this knowledge gap, cohorts of Asian citrus psyllid adults were allowed 1-wk acquisition access period (AAP) on flushing and nonflushing shoots of qPCR-tested symptomatic (CLas+) and asymptomatic (CLas-) 10-yr-old sweet orange trees under field conditions. After the AAP, they were tested for CLas by qPCR. Progeny Asian citrus psyllid adults that emerged 4 wk post-AAP were similarly retrieved and tested. Eighty percent of flushing and 30% of nonflushing CLas+ trees produced infective Asian citrus psyllid adults, indicating that flush shoots have greater potential to be inoculum sources for CLas acquisition. Concomitantly, 21.1% and 6.0% infective adults were retrieved, respectively, from flushing and nonflushing CLas+ trees, indicating that Asian citrus psyllid adults acquire CLas more efficiently from flush shoots relative to mature shoots. In addition, 12.1% of infective Asian citrus psyllid adult progeny were obtained from 70% of flushing CLas+ trees. Significantly lower mean Ct values were also obtained from infective adults retrieved from flushing relative to nonflushing trees. The results underscore the role of flush shoots in CLas acquisition and the need to protect citrus trees from Asian citrus psyllid infestations during flush cycles. © The Authors 2016. Published by Oxford University Press on behalf of Entomological Society of America. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Rastogi, Vaibhav; Singh, Devina; Mazza, Joseph J; Yang, Dennis; Parajuli, Dipendra; Yale, Steven H
2018-04-12
Flushing is the subjective sensation of warmth accompanied by visible cutaneous erythema occurring throughout the body with a predilection for the face, neck, pinnae, and upper trunk where the skin is thinnest and cutaneous vessels are superficially located and in greatest numbers. Flushing can be present in either a wet or dry form depending upon whether neural-mediated mechanisms are involved. Activation of the sympathetic nervous system results in wet flushing, accompanied by diaphoresis, due to concomitant stimulation of eccrine sweat glands. Wet flushing is caused by certain medications, panic disorder and paroxysmal extreme pain disorder (PEPD). Vasodilator mediated flushing due to the formation and release of a variety of biogenic amines, neuropeptides and phospholipid mediators such as histamine, serotonin and prostaglandins respectively, typically presents as dry flushing where sweating is characteristically absent. Flushing occurring with neuroendocrine tumors accompanied by gastrointestinal symptoms is generally of the dry flushing variant, which may be an important clinical clue to the differential diagnosis. A number of primary diseases of the gastrointestinal tract cause flushing, and conversely extra-intestinal conditions are associated with flushing and gastrointestinal symptoms. Gastrointestinal findings vary and include one or more of the following non-specific symptoms such as abdominal pain, nausea, vomiting, diarrhea or constipation. The purpose of this review is to provide a focused comprehensive discussion on the presentation, pathophysiology, diagnostic evaluation and management of those diseases that arise from the gastrointestinal tract or other site that may cause gastrointestinal symptoms secondarily accompanied by flushing. The paper is divided into two parts given the scope of conditions that cause flushing and affect the gastrointestinal tract. Part 1 covered is neuroendocrine tumors, (carcinoid, pheochromocytomas, vasoactive intestinal polypeptide, medullary carcinoma of the thyroid) polyneuropathy, organomegaly, endocrinopathy, monoclonal protein, skin changes (POEMS), and conditions involving mast cells and basophils. Part 2 covered is dumping syndrome, mesenteric traction syndrome, rosacea, hyperthyroidism and thyroid storm, anaphylaxis, panic disorders, paroxysmal extreme pain disorder, and food, alcohol and medications. © 2018 Marshfield Clinic.
46 CFR 194.20-11 - Flushing systems.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 7 2014-10-01 2014-10-01 false Flushing systems. 194.20-11 Section 194.20-11 Shipping... Flushing systems. (a) Provision shall be made for flushing away chemical spills. (b) If a drainage system is installed, it shall be separate from any other drainage system. ...
46 CFR 194.20-11 - Flushing systems.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 7 2013-10-01 2013-10-01 false Flushing systems. 194.20-11 Section 194.20-11 Shipping... Flushing systems. (a) Provision shall be made for flushing away chemical spills. (b) If a drainage system is installed, it shall be separate from any other drainage system. ...
46 CFR 194.20-11 - Flushing systems.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 7 2010-10-01 2010-10-01 false Flushing systems. 194.20-11 Section 194.20-11 Shipping... Flushing systems. (a) Provision shall be made for flushing away chemical spills. (b) If a drainage system is installed, it shall be separate from any other drainage system. ...
A method for measuring the cleaning effect of flushing disinfectors.
Cederberg, A.; Osterberg, K.
1980-01-01
A method is presented with which the mechanical cleaning effect of flushing disinfectors can be estimated independently of the thermal disinfecting effect of the hot flushing water. This makes it possible to specify the demands to be placed on the disinfecting effect of flushing with water of 85 degrees C or more. Bacillus stearothermophilus spores suspended in faeces were used as indicators because of their non-sensitivity to the hot-water temperature. Their elimination by flushing could thus be attributed to the mechanical effect of the water and not to the disinfecting effect of the temperature. A simple bacteriological technique was used, and the elimination factor (EF) was calculated as the ratio of the number of micro-organisms in the contamination before and after flushing. By using flushing water below 50 degrees C for 130 s the EF on a bedpan was about 10(4)-10(6). The effect of flushing with water of the same temperature for only half that time was somewhat weaker and when the temperature was raised to 85 degrees C after half the flushing time the effect was somewhat stronger. It can be presumed that the conventional disinfecting phase with hot (85 degrees C) water for about 45 s in the commonly used flushing units could be substantially shortened and the costs of their use thereby reduced. PMID:6820026
Rohlffs, Fiona; Tsilimparis, Nikolaos; Saleptsis, Vasilis; Diener, Holger; Debus, E Sebastian; Kölbel, Tilo
2017-02-01
To investigate the amount of gas released from Zenith thoracic stent-grafts using standard saline flushing vs the carbon dioxide flushing technique. In an experimental bench setting, 20 thoracic stent-grafts were separated into 2 groups of 10 endografts. One group of grafts was flushed with 60 mL saline and the other group was flushed with carbon dioxide for 5 minutes followed by 60 mL saline. All grafts were deployed into a water-filled container with a curved plastic pipe; the deployment was recorded and released gas was measured using a calibrated setup. Gas was released from all grafts in both study groups during endograft deployment. The average amount of released gas per graft was significantly lower in the study group with carbon dioxide flushing (0.79 vs 0.51 mL, p=0.005). Thoracic endografts release significant amounts of air during deployment if flushed according to the instructions for use. Application of carbon dioxide for the flushing of thoracic stent-grafts prior to standard saline flush significantly reduces the amount of gas released during deployment. The additional use of carbon dioxide should be considered as a standard flush technique for aortic stent-grafts, especially in those implanted in proximal aortic segments, to reduce the risk of air embolism and stroke.
Guan, Zhuo; Tang, Xiang-Yu; Nishimura, Taku; Katou, Hidetaka; Liu, Hui-Yun; Qing, Jing
2018-02-01
Soil contamination by diesel has been often reported as a result of accidental spillage, leakage and inappropriate use. Surfactant-enhanced soil flushing is a common remediation technique for soils contaminated by hydrophobic organic chemicals. In this study, soil flushing with linear alkylbenzene sulfonates (LAS, an anionic surfactant) was conducted for intact columns (15cm in diameter and 12cm in length) of diesel-contaminated farmland purple soil aged for one year in the field. Dynamics of colloid concentration in column outflow during flushing, diesel removal rate and resulting soil macroporosity change by flushing were analyzed. Removal rate of n-alkanes (representing the diesel) varied with the depth of the topsoil in the range of 14%-96% while the n-alkanes present at low concentrations in the subsoil were completely removed by LAS-enhanced flushing. Much higher colloid concentrations and larger colloid sizes were observed during LAS flushing in column outflow compared to water flushing. The X-ray micro-computed tomography analysis of flushed and unflushed soil cores showed that the proportion of fine macropores (30-250μm in diameter) was reduced significantly by LAS flushing treatment. This phenomenon can be attributed to enhanced clogging of fine macropores by colloids which exhibited higher concentration due to better dispersion by LAS. It can be inferred from this study that the application of LAS-enhanced flushing technique in the purple soil region should be cautious regarding the possibility of rapid colloid-associated contaminant transport via preferential pathways in the subsurface and the clogging of water-conducting soil pores. Copyright © 2017. Published by Elsevier B.V.
Truitt, E B; Gaynor, C R; Mehl, D L
1987-01-01
Aspirin (ASA) was tested in a group of 8 Oriental and 3 Occidental subjects who were shown in a previous study to respond to small doses of ethanol (0.06-0.25 g/kg) with facial flushing. They were compared to a similar group of 11 non-flushing Occidental subjects following a larger ethanol dose (0.37 g/kg) to determine if similar effects could be produced in less sensitive individuals. Control tests of blood ethanol and acetaldehyde (AcH) levels (calculated from breath), facial and neck skin temperatures, body sway (Romberg test), blood pressure, heart rate and 10 Subjective High Assessment Scales (SHAS-Judd, 1977) were conducted before and at 15, 30, 60 and 90 minutes after drinking ethanol as vodka in orange juice. The tests were repeated one week later one hour after receiving 0.64 gm of ASA orally. ASA produced slight changes in the early absorption of ethanol and small decreases in AcH levels in the flushing and non-flushing groups. Facial flushing was markedly reduced in the flushing group, but was slightly increased in the non-flushing Occidentals. Body sway was reduced by ASA in both groups. An alcohol-induced increase in heart rate in the flushing group was reduced with no change in blood pressure. SHAS subjective parameters were widely variable, but indicated that ASA produced reduced sleepiness and earlier relaxation in the flushing group. It is concluded that ASA can block alcohol-induced facial flushing in sensitive subjects and also reduces body sway in the Romberg test and alters some subjective feelings of alcohol intoxication.
A hazard of the Intraflo continuous flush system.
Schwartz, A J; Stoner, B B; Jobes, D R
1977-01-01
Patency of pressure sensing systems can be provided by the Intraflow Continuous Flush System (Sorenson Research Company, Salt Lake City, UT 84115). This device allows continuous flow of flush solution through a regulatory valve while preventing transmission of the high pressure of the flush solution. The case presented describes the recognition of a false elevation of a monitored pressure secondary to the malfunction of the Intraflo regulatory valve. Elimination of the flush solution high pressure during monitoring prevents inappropriate data collection.
Management of Contaminants Stored in Low Permeability Zones - A State of the Science Review
2013-10-01
Tank 3: Permanganate ................................................................................................... 193...Treatment options explored include steady water flushing (control), enhance water flushing, flushing permanganate , a dechlorinating culture (KB1...Remediation Tank Experiments (OoM: Order of Magnitude. PV: Pore Volume) 2. Enhanced flushing (79 PVs after loading) 3. Permanganate (45 PVs
Oberwittler, H; Baccara-Dinet, M
2006-06-01
Nicotinic acid (NA) is highly effective and widely used in the management of dyslipidaemia. For many patients, the side effect of flushing of the face and upper body leads to discontinuation. Flushing with NA is mediated by prostaglandins, and as acetyl salicylic acid (ASA, 'aspirin') is a highly effective inhibitor of prostaglandin synthesis, there is a rationale for its use to prevent or reduce the severity of NA-related flushing. This literature survey identified four studies specifically exploring the utility of ASA in preventing NA-related flushing in healthy volunteers. Twenty-three NA studies, where ASA was mandatory or optional within the protocol, and four studies, where background ASA therapy was reported in most participants, were also identified. Although the incidence of flushing in studies using ASA was often high, discontinuation rates due to flushing were low (mean 7.7%). This figure compares favourably with discontinuation rates with NA commonly reported in the literature (up to approximately 40%). There is good supportive evidence for the use of ASA in reducing the severity of NA-related flushing.
Li, Dong; Sun, Delin; Hu, Siyang; Hu, Jing; Yuan, Xingzhong
2016-02-01
A conceptual design and experiments, electrochemistry-flushing (E-flushing), using electrochemistry to enhance flushing efficiency for the remediation of Cr(Ⅵ)-contaminated soil is presented. The rector contained three compartments vertically superposed. The upper was airtight cathode compartment containing an iron-cathode. The middle was soil layer. The bottom was anode compartment containing an iron-anode and connected to a container by circulation pumps. H2 and OH(-) ions were produced at cathode. H2 increased the gas pressure in cathode compartment and drove flushing solution into soil layer forming flushing process. OH(-) ions entered into soil layer by eletromigration and hydraulic flow to enhance the desorption of Cr(Ⅵ). High potential gradient was applied to accelerate the electromigration of desorbed Cr(Ⅵ) ions and produced joule heat to increase soil temperature to enhance Cr(Ⅵ) desorption. In anode compartment, Fe(2+) ions produced at iron-anode reduced the desorbed Cr(Ⅵ) into Cr(3+) ions, which reacted with OH(-) ions forming Cr(OH)3. Experimental results show that Cr(Ⅵ) removal efficiency of E-flushing experiments was more than double of flushing experiments and reached the maximum of removal efficiency determined by desorption kinetics. All electrochemistry processes were positively used in E-flushing technology. Copyright © 2015 Elsevier Ltd. All rights reserved.
Neurokinin B administration induces hot flushes in women.
Jayasena, Channa N; Comninos, Alexander N; Stefanopoulou, Evgenia; Buckley, Adam; Narayanaswamy, Shakunthala; Izzi-Engbeaya, Chioma; Abbara, Ali; Ratnasabapathy, Risheka; Mogford, Julianne; Ng, Noel; Sarang, Zubair; Ghatei, Mohammad A; Bloom, Stephen R; Hunter, Myra S; Dhillo, Waljit S
2015-02-16
Neurokinin B (NKB) is a hypothalamic neuropeptide binding preferentially to the neurokinin 3 receptor. Expression of the gene encoding NKB is elevated in postmenopausal women. Furthermore, rodent studies suggest that NKB signalling may mediate menopausal hot flushes. However, the effects of NKB administration on hot flushes have not been investigated in humans. To address this, we performed a randomised, double-blinded, placebo-controlled, 2-way cross-over study. Ten healthy women were admitted to a temperature and humidity-controlled research unit. Participants received 30 minute intravenous infusions of NKB and vehicle in random order. Symptoms, heart rate, blood pressure, sweating and skin temperature were compared between NKB and vehicle in a double-blinded manner. Eight of ten participants experienced flushing during NKB infusion with none experiencing flushing during vehicle infusion (P = 0.0007). Significant elevations in heart rate (P = 0.0106 vs. pre-symptoms), and skin temperature measured using skin probe (P = 0.0258 vs. pre-symptoms) and thermal imaging (P = 0.0491 vs. pre-symptoms) characteristic of menopausal flushing were observed during hot flush episodes. Our findings provide evidence that NKB administration can cause hot flushes in women. Further studies are required to determine if pharmacological blockade of NKB signalling could inhibit hot flushes during the menopause and during treatment for sex-steroid dependent cancers.
Spatio-temporal evolution of apparent resistivity during coal-seam hydraulic flushing
NASA Astrophysics Data System (ADS)
Li, Dexing; Wang, Enyuan; Song, Dazhao; Qiu, Liming; Kong, Xiangguo
2018-06-01
Hydraulic flushing in gas predrainage is widely used, but the hydraulic-flushing effect is evaluated in a traditional way, by determining the desorption volume, moisture content, gas drainage rate and other conventional indices. To verify the rationality and feasibility of the multielectrode resistivity method in the evaluation of coal-seam hydraulic flushing and to research the spatio-temporal evolution of apparent resistivity during hydraulic flushing, a field test was conducted in 17# coal seam at Nuodong Mine, Guizhou. During hydraulic flushing, four stages were defined according to the variation in coal rock resistivity with time, namely, the preparation stage, the sharply decreasing stage, the rapidly increasing stage and the steady stage. The apparent resistivity of the coal rock mass is affected mainly by its own degree of fragmentation and flushing volume. A more serious rupture and a greater flushing volume yield a smaller apparent resistivity during the sharply decreasing stage and a higher resistivity during the stable stage. After three months of gas predrainage, the residual gas content and the gas pressure at different points in the expected affected area decrease below the critical value. Changes in the residual gas content and gas pressure at these points are consistent with the apparent resistivity, which validates the rationality and feasibility of the multielectrode resistivity method in evaluating coal-seam hydraulic flushing.
Tuomikoski, P; Mikkola, T S; Tikkanen, M J; Ylikorkala, O
2010-10-01
Menopausal hot flushes may affect the responses of various vascular risk factors to hormone therapy (HT). We compared the responses of biochemical markers for cardiovascular diseases to HT in recently postmenopausal women with tolerable or intolerable hot flushes. Healthy, non-smoking freshly postmenopausal women (n = 150) with no previous HT use were studied. Seventy-two women reported intolerable hot flushes (> or =7 moderate/severe episodes/day) and 78 women tolerable hot flushes (< or =3 mild episodes/day). The participants were treated in randomized order with either transdermal estradiol gel (1 mg), oral estradiol valerate (2 mg) with or without medroxyprogesterone acetate (5 mg), or placebo for 6 months. Treatment-induced changes in lipids, lipoproteins, apolipoproteins, sex hormone binding globulin (SHBG) and high-sensitivity C-reactive protein were compared. The trial is registered in the US National Institutes of Health Clinical Research Registry (no. NCT00668603). Pretreatment hot flush status was not related to the responses of these markers to different forms of HT. However, when all active regimens were evaluated together as a post-hoc analysis, 7/10 markers showed a tendency toward greater beneficial changes in women with intolerable hot flushes. Furthermore, in women with intolerable hot flushes and with HT use, the increases in SHBG (Spearman's rho = - 0.570, p < 0.001) were related to the reductions in hot flushes during the use of HT. Hot flushes appear to be no significant determinant for the responses of vascular markers to HT use.
An intensive behavioral weight loss intervention and hot flushes in women.
Huang, Alison J; Subak, Leslee L; Wing, Rena; West, Delia Smith; Hernandez, Alexandra L; Macer, Judy; Grady, Deborah
2010-07-12
Higher body mass index is associated with worse hot flushes during menopause but the effect of weight loss on flushing is unclear. Self-administered questionnaires were used to assess bothersome hot flushes in a 6-month randomized controlled trial of an intensive behavioral weight loss program (intervention) vs a structured health education program (control) in 338 women who were overweight or obese and had urinary incontinence. Weight, body mass index, abdominal circumference, physical activity, calorie intake, blood pressure, and physical and mental functioning were assessed at baseline and at 6 months. Repeated-measures proportional odds models examined intervention effects on bothersome hot flushes and potential mediating factors. Approximately half of participants (n = 154) were at least slightly bothered by hot flushes at baseline. Among these women, the intervention was associated with greater improvement in bothersome flushes vs control (odds ratio [OR] for improvement by 1 Likert category, 2.25; 95% confidence interval [CI], 1.20-4.21). Reductions in weight (OR, 1.32; 95% CI, 1.08-1.61; per 5-kg decrease), body mass index (1.17; 1.05-1.30; per 1-point decrease), and abdominal circumference (1.32; 1.07-1.64; per 5-cm decrease) were each associated with improvement in flushing, but changes in physical activity, calorie intake, blood pressure, and physical and mental functioning were not related. The effect of the intervention on flushing was modestly diminished after adjustment for multiple potential mediators (OR, 1.92; 95% CI, 0.95-3.89). Among women who were overweight or obese and had bothersome hot flushes, an intensive behavioral weight loss intervention resulted in improvement in flushing relative to control. Trial Registration clinicaltrials.gov Identifier: NCT00091988.
Duration of Menopausal Hot Flushes and Associated Risk Factors
Freeman, Ellen W.; Sammel, Mary D.; Lin, Hui; Liu, Ziyue; Gracia, Clarisa R.
2011-01-01
OBJECTIVE To estimate the duration of moderate-to-severe menopausal hot flushes and identify potential risk factors for hot flush duration. METHODS The Penn Ovarian Aging Study cohort was followed for 13 years. Hot flushes were evaluated at 9-month to 12-month intervals through in-person interviews. The primary outcome was the duration of moderate to severe hot flushes, estimated by survival analysis (N=259). Potential risk factors included menopausal stage, age, race, reproductive hormone levels, body mass index (BMI) and current smoking. A secondary analysis included women who reported any hot flushes (N=349). RESULTS The median duration of moderate to severe hot flushes was 10.2 years and was strongly associated with menopausal stage at onset. Hot flushes that commenced near entry into the menopause transition had a median duration >greater than 11.57 years; onset in the early transition stage had a median duration of 7.35 years (95% CI 4.94, 8.89), P<0.001); and onset in the late transition to postmenopausal stages had a median duration of 3.84 years (95% CI: 1.77, 5.52), P<0.001. The most common ages at onset of moderate-to-severe hot flushes were 45–49 years (median duration 8.1 years; 95% CI 5.12, 9.28). African American women had a longer duration of hot flushes than white women in adjusted analysis. CONCLUSIONS The median duration of hot flushes considerably exceeded the time frame that is generally accepted in clinical practice. The identified risk factors, particularly menopausal stage, race, and BMI, are important to consider in individualizing treatment and evaluating the risk to benefit ratio of hormones and other therapies. PMID:21508748
21 CFR 870.1210 - Continuous flush catheter.
Code of Federal Regulations, 2014 CFR
2014-04-01
...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1210 Continuous flush catheter. (a) Identification. A continuous flush catheter is an attachment to a catheter-transducer system...
21 CFR 870.1210 - Continuous flush catheter.
Code of Federal Regulations, 2012 CFR
2012-04-01
...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1210 Continuous flush catheter. (a) Identification. A continuous flush catheter is an attachment to a catheter-transducer system...
21 CFR 870.1210 - Continuous flush catheter.
Code of Federal Regulations, 2013 CFR
2013-04-01
...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1210 Continuous flush catheter. (a) Identification. A continuous flush catheter is an attachment to a catheter-transducer system...
Aerosol Generation by Modern Flush Toilets.
Johnson, David; Lynch, Robert; Marshall, Charles; Mead, Kenneth; Hirst, Deborah
A microbe-contaminated toilet will produce bioaerosols when flushed. We assessed toilet plume aerosol from high efficiency (HET), pressure-assisted high efficiency (PAT), and flushometer (FOM) toilets with similar bowl water and flush volumes. Total and droplet nuclei "bioaerosols" were assessed. Monodisperse 0.25-1.9- μ m fluorescent microspheres served as microbe surrogates in separate trials in a mockup 5 m 3 water closet (WC). Bowl water seeding was approximately 10 12 particles/mL. Droplet nuclei were sampled onto 0.2- μ m pore size mixed cellulose ester filters beginning 15 min after the flush using open-face cassettes mounted on the WC walls. Pre- and postflush bowl water concentrations were measured. Filter particle counts were analyzed via fluorescent microscopy. Bowl headspace droplet count size distributions were bimodal and similar for all toilet types and flush conditions, with 95% of droplets < 2 μ m diameter and > 99% < 5 μ m. Up to 145,000 droplets were produced per flush, with the high-energy flushometer producing over three times as many as the lower energy PAT and over 12 times as many as the lowest energy HET despite similar flush volumes. The mean numbers of fluorescent droplet nuclei particles aerosolized and remaining airborne also increased with flush energy. Fluorescent droplet nuclei per flush decreased with increasing particle size. These findings suggest two concurrent aerosolization mechanisms-splashing for large droplets and bubble bursting for the fine droplets that form droplet nuclei.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hanson, P.J.; Isebrands, J.G.; Dickson, R.E.
1988-03-01
Oak (Quercus) seedlings exhibit a pattern of shoot growth known to place demands on carbohydrate and nutrient reserves. This study was designed to determine ontogenetic patterns in CO{sub 2} exchanges properties of red oak leaves, and to determine if individual leaf CO{sub 2} exchange rates (CER) increase in response to the assimilate demand placed on a seedling during flushing. Northern red oak (Q. rubra L.) seedlings were grown in environments favorable for multiple flushes of shoot growth. Measurements of CER on single, attached, median leaves from each flush were made over a range of photosynthetic photon flux densities on plantsmore » at nine stages of seedling development through three flushes of growth. Carbon dioxide exchange rate of red oak leaves increased during leaf development up to and beyond full leaf expansion before decreasing an unusual pattern of photosynthesis during leaf ontogeny. Furthermore, first- and second-flush leaf CER initially decreased and then increased in conjunction with the third flush of shoot growth. These patterns indicate that red oak leaves have a capacity for CER adjustment in response to increase sink demand.« less
Etiologies and management of cutaneous flushing: Nonmalignant causes.
Sadeghian, Azeen; Rouhana, Hailey; Oswald-Stumpf, Brittany; Boh, Erin
2017-09-01
The flushing phenomenon may represent a physiologic or a pathologic reaction. Although flushing is usually benign, it is prudent that the physician remains aware of potentially life-threatening conditions associated with cutaneous flushing. A thorough investigation should be performed if the flushing is atypical or not clearly associated with a benign underlying process. The diagnosis often relies on a pertinent history, review of systems, physical examination, and various laboratory and imaging modalities, all of which are discussed in the 2 articles in this continuing medical education series. This article reviews flushing associated with fever, hyperthermia, emotions, menopause, medications, alcohol, food, hypersensitivity reactions, rosacea, hyperthyroidism, dumping syndrome, superior vena cava syndrome, and neurologic etiologies. Copyright © 2016 American Academy of Dermatology, Inc. Published by Elsevier Inc. All rights reserved.
C. S., Lim; M. S., Shaharuddin; W. Y., Sam
2013-01-01
Introduction: A cross sectional study was conducted to estimate risk of exposure to lead via tap water ingestion pathway for the population of Seri Kembangan (SK). Methodology: By using purposive sampling method, 100 respondents who fulfilled the inclusive criteria were selected from different housing areas of SK based on geographical population distribution. Residents with filtration systems installed were excluded from the study. Questionnaires were administered to determine water consumption-related information and demographics. Two water samples (first-flushed and fully-flushed samples) were collected from kitchen tap of each household using HDPE bottles. A total of 200 water samples were collected and lead concentrations were determined using a Graphite Furnace Atomic Absorption Spectrophotometer (GFAAS). Results: Mean lead concentration in first-flushed samples was 3.041± SD 6.967µg/L and 1.064± SD 1.103µg/L for fully-flushed samples. Of the first-flushed samples, four (4) had exceeded the National Drinking Water Quality Standard (NDWQS) lead limit value of 10µg/L while none of the fully-flushed samples had lead concentration exceeded the limit. There was a significant difference between first-flushed samples and fully-flushed samples and flushing had elicited a significant change in lead concentration in the water (Z = -5.880, p<0.05). It was also found that lead concentration in both first-flushed and fully flushed samples was not significantly different across nine (9) areas of Seri Kembangan (p>0.05). Serdang Jaya was found to have the highest lead concentration in first-flushed water (mean= 10.44± SD 17.83µg/L) while Taman Universiti Indah had the highest lead concentration in fully-flushed water (mean=1.45± SD 1.83µg/L). Exposure assessment found that the mean chronic daily intake (CDI) was 0.028± SD 0.034µgday-1kg-1. None of the hazard quotient (HQ) value was found to be greater than 1. Conclusion: The overall quality of water supply in SK was satisfactory because most of the parameters tested in this study were within the range of permissible limit and only a few samples had exceeded the standard values for lead and pH. Non-carcinogenic risk attributed to ingestion of lead in SK tap water was found to be negligible. PMID:23445691
Lim, C S; Shaharuddin, M S; Sam, W Y
2012-11-21
A cross sectional study was conducted to estimate risk of exposure to lead via tap water ingestion pathway for the population of Seri Kembangan (SK). By using purposive sampling method, 100 respondents who fulfilled the inclusive criteria were selected from different housing areas of SK based on geographical population distribution. Residents with filtration systems installed were excluded from the study. Questionnaires were administered to determine water consumption-related information and demographics. Two water samples (first-flushed and fully-flushed samples) were collected from kitchen tap of each household using HDPE bottles. A total of 200 water samples were collected and lead concentrations were determined using a Graphite Furnace Atomic Absorption Spectrophotometer (GFAAS). Mean lead concentration in first-flushed samples was 3.041± SD 6.967µg/L and 1.064± SD 1.103µg/L for fully-flushed samples. Of the first-flushed samples, four (4) had exceeded the National Drinking Water Quality Standard (NDWQS) lead limit value of 10µg/L while none of the fully-flushed samples had lead concentration exceeded the limit. There was a significant difference between first-flushed samples and fully-flushed samples and flushing had elicited a significant change in lead concentration in the water (Z = -5.880, p<0.05). It was also found that lead concentration in both first-flushed and fully flushed samples was not significantly different across nine (9) areas of Seri Kembangan (p>0.05). Serdang Jaya was found to have the highest lead concentration in first-flushed water (mean= 10.44± SD 17.83µg/L) while Taman Universiti Indah had the highest lead concentration in fully-flushed water (mean=1.45± SD 1.83µg/L). Exposure assessment found that the mean chronic daily intake (CDI) was 0.028± SD 0.034µgday-1kg-1. None of the hazard quotient (HQ) value was found to be greater than 1. The overall quality of water supply in SK was satisfactory because most of the parameters tested in this study were within the range of permissible limit and only a few samples had exceeded the standard values for lead and pH. Non-carcinogenic risk attributed to ingestion of lead in SK tap water was found to be negligible.
Apical dominance and apical control in multiple flushing of temperate woody species.
M. Cline; C. Harrington
2007-01-01
In young plants of many woody species, the first flush of growth in the spring may be followed by one or more flushes of the terminal shoot if growing conditions are favorable. The occurrence of these additional flushes may significantly affect crown form and structure. Apical dominance (AD) and apical control (AC) are thought to be important control mechanisms in this...
Ding, Lanyan; Yuen, Lok-Wa; Shell, Duane F.
2018-01-01
This study explored bystanders’ willingness to help a friend who flushes when drinking to reduce his/her drinking. Alcohol-related facial flushing is an indicator of an inherited variant enzyme, aldehyde dehydrogenase (ALDH), that impairs alcohol metabolism and increases drinkers’ lifetime risk of certain aerodigestive cancers. Individuals who flush should reduce their alcohol exposure, but they may continue to drink if social pressures and rules of etiquette make not drinking socially risky. The analysis used data from 2912 undergraduate students from 13 universities in southwestern, central and northeastern China from a survey asking how they respond to someone’s flushing in various scenarios. Latent class analysis grouped students by similar responses to flushing. A multinomial logistic regression explored how class membership was associated with knowledge, drinking status, and reactions to one’s own flushing. Five classes were derived from the latent class analysis, ranging from always intervene to mostly hesitate to help; in between were classes of students who were willing to help in some scenarios and hesitant in other scenarios. Only 11.6% students knew the connection between facial flushing and impaired alcohol metabolism, and knowledgeable students were somewhat more likely to assist when they saw someone flushing. In the absence of knowledge, other factors—such as drinking status, the gender of the bystander, the gender of the person who flushed, and degree of friendship with the person who flushed—determined how willing a person was to help someone reduce or stop drinking. Class membership was predicted by knowledge, gender, drinking status, and reactions to one’s own flushing. Of these 4 factors, knowledge and reactions to one’s own flushing could be influenced through alcohol education programs. It will take some time for alcohol education to catch up to and change social and cultural patterns of drinking. Meanwhile, motivational strategies should be developed to increase the willingness of bystanders to assist friends and to create a social expectation that flushers should stop or reduce their drinking. PMID:29693597
Gschwendtner, Silvia; Alatossava, Tapani; Kublik, Susanne; Fuka, Mirna Mrkonjić; Schloter, Michael; Munsch-Alatossava, Patricia
2016-01-01
The quality and safety of raw milk still remains a worldwide challenge. Culture-dependent methods indicated that the continuous N2 gas-flushing of raw milk reduced the bacterial growth during cold storage by up to four orders of magnitude, compared to cold storage alone. This study investigated the influence of N2 gas-flushing on bacterial diversity in bovine raw-milk samples, that were either cold stored at 6°C or additionally flushed with pure N2 for up to one week. Next-generation sequencing (NGS) of the V1-V2 hypervariable regions of 16S rRNA genes, derived from amplified cDNA, which was obtained from RNA directly isolated from raw-milk samples, was performed. The reads, which were clustered into 2448 operational taxonomic units (OTUs), were phylogenetically classified. Our data revealed a drastic reduction in the diversity of OTUs in raw milk during cold storage at 6°C at 97% similarity level; but, the N2-flushing treatment alleviated this reduction and substantially limited the loss of bacterial diversity during the same cold-storage period. Compared to cold-stored milk, the initial raw-milk samples contained less Proteobacteria (mainly Pseudomonadaceae, Moraxellaceae and Enterobacteriaceae) but more Firmicutes (mainly Ruminococcaceaea, Lachnospiraceae and Oscillospiraceaea) and Bacteroidetes (mainly Bacteroidales). Significant differences between cold-stored and additionally N2-flushed milk were mainly related to higher levels of Pseudomononadaceae (including the genera Pseudomonas and Acinetobacter) in cold-stored milk samples; furthermore, rare taxa were better preserved by the N2 gas flushing compared to the cold storage alone. No major changes in bacterial composition with time were found regarding the distribution of the major 9 OTUs, that dominated the Pseudomonas genus in N2-flushed or non-flushed milk samples, other than an intriguing predominance of bacteria related to P. veronii. Overall, this study established that neither bacteria causing milk spoilage nor any well-known human pathogen or anaerobe benefited from the N2 gas flushing even though the N2-flushed and non-flushed cold-stored milk differed in bacterial counts by up to 104-fold.
Kublik, Susanne; Fuka, Mirna Mrkonjić; Schloter, Michael; Munsch-Alatossava, Patricia
2016-01-01
The quality and safety of raw milk still remains a worldwide challenge. Culture-dependent methods indicated that the continuous N2 gas-flushing of raw milk reduced the bacterial growth during cold storage by up to four orders of magnitude, compared to cold storage alone. This study investigated the influence of N2 gas-flushing on bacterial diversity in bovine raw-milk samples, that were either cold stored at 6°C or additionally flushed with pure N2 for up to one week. Next-generation sequencing (NGS) of the V1-V2 hypervariable regions of 16S rRNA genes, derived from amplified cDNA, which was obtained from RNA directly isolated from raw-milk samples, was performed. The reads, which were clustered into 2448 operational taxonomic units (OTUs), were phylogenetically classified. Our data revealed a drastic reduction in the diversity of OTUs in raw milk during cold storage at 6°C at 97% similarity level; but, the N2-flushing treatment alleviated this reduction and substantially limited the loss of bacterial diversity during the same cold-storage period. Compared to cold-stored milk, the initial raw-milk samples contained less Proteobacteria (mainly Pseudomonadaceae, Moraxellaceae and Enterobacteriaceae) but more Firmicutes (mainly Ruminococcaceaea, Lachnospiraceae and Oscillospiraceaea) and Bacteroidetes (mainly Bacteroidales). Significant differences between cold-stored and additionally N2-flushed milk were mainly related to higher levels of Pseudomononadaceae (including the genera Pseudomonas and Acinetobacter) in cold-stored milk samples; furthermore, rare taxa were better preserved by the N2 gas flushing compared to the cold storage alone. No major changes in bacterial composition with time were found regarding the distribution of the major 9 OTUs, that dominated the Pseudomonas genus in N2-flushed or non-flushed milk samples, other than an intriguing predominance of bacteria related to P. veronii. Overall, this study established that neither bacteria causing milk spoilage nor any well-known human pathogen or anaerobe benefited from the N2 gas flushing even though the N2-flushed and non-flushed cold-stored milk differed in bacterial counts by up to 104-fold. PMID:26730711
Endoscope system with plasma flushing and coaxial round jet nozzle for off-pump cardiac surgery.
Horiuchi, Tetsuya; Masamune, Ken; Iwase, Yuki; Ymashita, Hiromasa; Tsukihara, Hiroyuki; Motomura, Noboru; Ohta, Yuji; Dohi, Takeyoshi
2011-07-01
To develop a new endoscope for performing simple surgical tasks inside the blood-filled cardiac atrium/chamber, that is, "off-pump" cardiac surgeries. We developed the endoscope system with plasma flushing and coaxial round jet nozzle. The "plasma flushing" system was invented to observe the interior of the blood-filled heart by displacing blood cells in front of the endoscope tip. However, some areas could not be observed with simple flushing of the liquid because the flushed liquid mixed with blood. Further, a large amount of liquid had to be flushed, which posed a risk of cardiac damage caused by excess volume. Therefore, to safely capture high-resolution images of the interior of the heart, an endoscope with a coaxial round jet nozzle through which plasma is flushed has been developed. And to reduce the volume of flushed liquid, the synchronization system of heartbeat and the endoscope system with plasma flushing has been developed. We conducted an in vivo experiment to determine whether we could observe intracardiac tissues in swine without the use of a heart-lung machine. As a result, we successfully observed intracardiac tissues without using a heart-lung machine. By using a coaxial nozzle, we could even observe the tricuspid valve. Moreover, we were able to save up to 30% of the flushed liquid by replacing the original system with a synchronization system. And we evaluated the performance of the endoscope with the coaxial round jet nozzle by conducting fluid analysis and an in vitro experiment. We successfully observed intracardiac tissues without using a heart-lung machine. By using a coaxial nozzle, we could even observe the tricuspid valve. And by replacing an original system to a synchronization system, we were able to save up to 30% of the flushed liquid. As a follow-up study, we plan to create a surgical flexible device for valve disease that can grasp, staple, and repair cardiac valves by endoscopic visualization.
Simpson, Catherine R.; Alabi, Olufemi J.; Nelson, Shad D.; Telagamsetty, Srilakshmi; Jifon, John L.
2016-01-01
Studies were conducted to relate the influence of the physical characteristics, leaf nutrient content and phloem sap amino acid concentration of citrus flush shoots on the densities of various Diaphorina citri life stages. Adult D. citri preferentially selected young shoots for feeding and numbers of D. citri immatures were positively correlated with flush shoot softness. Young flush shoots had higher concentrations of macro and micro nutrients relative to mature ones and this was associated with higher densities of all D. citri life stages. All D. citri life stages were positively correlated with higher nitrogen-carbon (N:C), nitrogen:sulfur (N:S) and nitrogen:calcium (N:Ca) ratios in leaf tissue, while densities of adults were negatively related to calcium, manganese and boron levels. Concentrations of total and essential amino acids were highest in phloem sap of young expanding flush shoots in both grapefruit and lemon, but dramatically declined as flush shoots matured. The sulfur-containing amino acids cystine, methionine and taurine occurred only in younger flush shoots. In contrast, cystathionine was only present in phloem sap of mature shoots. These results clearly indicate that young citrus flush shoots are a nutritionally richer diet relative to mature shoots, thus explaining their preference by D. citri for feeding and reproduction. Conversely, tissue hardness and the lower nutritional quality of mature flush shoots may limit oviposition and immature development. The data suggest that both physical characteristics and nutritional composition of flush shoots and their phloem sap are important factors regulating host colonization and behavior of D. citri, and this interaction can impact the dynamics and spread of HLB in citrus groves. PMID:28030637
Pulmonary preservation studies: effects on endothelial function and pulmonary adenine nucleotides.
Paik, Hyo Chae; Hoffmann, Steven C; Egan, Thomas M
2003-02-27
Lung transplantation is an effective therapy plagued by a high incidence of early graft dysfunction, in part because of reperfusion injury. The optimal preservation solution for lung transplantation is unknown. We performed experiments using an isolated perfused rat lung model to test the effect of lung preservation with three solutions commonly used in clinical practice. Lungs were retrieved from Sprague-Dawley rats and flushed with one of three solutions: modified Euro-Collins (MEC), University of Wisconsin (UW), or low potassium dextran and glucose (LPDG), then stored cold for varying periods before reperfusion with Earle's balanced salt solution using the isolated perfused rat lung model. Outcome measures were capillary filtration coefficient (Kfc), wet-to-dry weight ratio, and lung tissue levels of adenine nucleotides and cyclic AMP. All lungs functioned well after 4 hr of storage. By 6 hr, UW-flushed lungs had a lower Kfc than LPDG-flushed lungs. After 8 hr of storage, only UW-flushed lungs had a measurable Kfc. Adenine nucleotide levels were higher in UW-flushed lungs after prolonged storage. Cyclic AMP levels correlated with Kfc in all groups. Early changes in endothelial permeability seemed to be better attenuated in lungs flushed with UW compared with LPDG or MEC; this was associated with higher amounts of adenine nucleotides. MEC-flushed lungs failed earlier than LPDG-flushed or UW-flushed lungs. The content of the solution may be more important for lung preservation than whether the ionic composition is intracellular or extracellular.
Aerosol Generation by Modern Flush Toilets
Johnson, David; Lynch, Robert; Marshall, Charles; Mead, Kenneth; Hirst, Deborah
2015-01-01
A microbe-contaminated toilet will produce bioaerosols when flushed. We assessed toilet plume aerosol from high efficiency (HET), pressure-assisted high efficiency (PAT), and flushometer (FOM) toilets with similar bowl water and flush volumes. Total and droplet nuclei “bioaerosols” were assessed. Monodisperse 0.25–1.9-μm fluorescent microspheres served as microbe surrogates in separate trials in a mockup 5 m3 water closet (WC). Bowl water seeding was approximately 1012 particles/mL. Droplet nuclei were sampled onto 0.2-μm pore size mixed cellulose ester filters beginning 15 min after the flush using open-face cassettes mounted on the WC walls. Pre- and postflush bowl water concentrations were measured. Filter particle counts were analyzed via fluorescent microscopy. Bowl headspace droplet count size distributions were bimodal and similar for all toilet types and flush conditions, with 95% of droplets <2 μm diameter and >99% <5 μm. Up to 145,000 droplets were produced per flush, with the high-energy flushometer producing over three times as many as the lower energy PAT and over 12 times as many as the lowest energy HET despite similar flush volumes. The mean numbers of fluorescent droplet nuclei particles aerosolized and remaining airborne also increased with flush energy. Fluorescent droplet nuclei per flush decreased with increasing particle size. These findings suggest two concurrent aerosolization mechanisms—splashing for large droplets and bubble bursting for the fine droplets that form droplet nuclei. PMID:26635429
Hot flushes and reproductive hormone levels during the menopausal transition.
Dhanoya, Tanveer; Sievert, Lynnette Leidy; Muttukrishna, Shanthi; Begum, Khurshida; Sharmeen, Taniya; Kasim, Adetayo; Chowdhury, Osul; Bentley, Gillian R
2016-07-01
Evidence suggests that hot flushes are associated with fluctuating levels of oestradiol (E2) during menopause, as well as changes in the levels of follicle-stimulating hormone (FSH) and inhibin B. The relationship between hot flushes and anti-Müllerian hormone (AMH) is unknown. To examine specific hormone levels and ethnic differences in relation to hot flushes. Data were drawn from 108 women aged 40-59 years. There were three groups of participants: European women in London, UK; Bangladeshi women in Sylhet, Bangladesh; and Bangladeshi women who had migrated to London as adults. Symptom information was collected via questionnaires. Serum blood samples were collected to detect inhibin B, AMH, FSH, and E2. AMH and FSH were significantly associated with the experience of hot flushes in the past 2 weeks. Inhibin B and E2 were not associated with hot flushes. Body mass index (BMI), ethnicity, and education level were associated with both the occurrence and the frequency hot flushes. Menopausal status was also associated with the frequency of hot flushes. Relationships between AMH, FSH and symptoms are indicative of women's progress through the menopausal transition. The influence of BMI and education suggest that lifestyle changes may contribute to the management of symptoms. This merits further research. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
30 CFR 56.7807 - Flushing the combustion chamber.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Rotary Jet Piercing Rotary Jet Piercing § 56.7807 Flushing the combustion chamber. The combustion chamber of a jet drill stem which has been sitting unoperated in a drill hole shall be flushed with a...
30 CFR 56.7807 - Flushing the combustion chamber.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Rotary Jet Piercing Rotary Jet Piercing § 56.7807 Flushing the combustion chamber. The combustion chamber of a jet drill stem which has been sitting unoperated in a drill hole shall be flushed with a...
Elhosary, Eman Abdelfatah Mohamed; Ewidea, Mahmoud Mohamed; Ahmed, Hamada Ahmed Hamada; El Khatib, Ayman
2018-02-01
[Purpose] To compare the effect of aerobic exercises versus laser acupuncture in treatment of postmenopausal hot flushes. [Subjects and Methods] This study was designed as single blind randomized controlled trial. A total of 48 postmenopausal women complained of hot flushes. Their ages ranged between 45 to 55 years and were randomly assigned into 2 equal groups: group (A), which received an aerobic exercises, and group (B), which received laser acupuncture. Both groups recieved 3 sessions per week for two months. The level of follicular stimulating hormone, lutelizing hormone, and hot flushes dairy card were assessed the severity of hot flahes before and after treatment program. [Results] There were Significant reduction in FSH, LH, and menopausal daily hot flush scale in group A compared with group B at the post treatment. [Conclusion] Eight week program of an aerobic exercises yields improvement in FSH, LH, and decrease in severity of hot flushes assessed by hot flush dairy card than laser acupuncture in the treatment of postmenopausal hot flashes.
Determining binder flushing causes in New York state.
DOT National Transportation Integrated Search
2014-12-01
In 2007, a number of asphalt pavements in New York State flushed. An extensive forensic and laboratory : investigation was conducted to determine why particular New York State asphalt pavements constructed in 2007 had : undergone atypical flush...
46 CFR 116.1110 - Drainage of flush deck vessels.
Code of Federal Regulations, 2013 CFR
2013-10-01
... ARRANGEMENT Drainage and Watertight Integrity of Weather Decks § 116.1110 Drainage of flush deck vessels. (a) Except as provided in paragraph (b) of this section, the weather deck on a flush deck vessel must be...
46 CFR 116.1110 - Drainage of flush deck vessels.
Code of Federal Regulations, 2012 CFR
2012-10-01
... ARRANGEMENT Drainage and Watertight Integrity of Weather Decks § 116.1110 Drainage of flush deck vessels. (a) Except as provided in paragraph (b) of this section, the weather deck on a flush deck vessel must be...
46 CFR 178.410 - Drainage of flush deck vessels.
Code of Federal Regulations, 2011 CFR
2011-10-01
... TONS) INTACT STABILITY AND SEAWORTHINESS Drainage of Weather Decks § 178.410 Drainage of flush deck vessels. (a) Except as provided in paragraph (b) of this section, the weather deck on a flush deck vessel...
46 CFR 178.410 - Drainage of flush deck vessels.
Code of Federal Regulations, 2012 CFR
2012-10-01
... TONS) INTACT STABILITY AND SEAWORTHINESS Drainage of Weather Decks § 178.410 Drainage of flush deck vessels. (a) Except as provided in paragraph (b) of this section, the weather deck on a flush deck vessel...
46 CFR 116.1110 - Drainage of flush deck vessels.
Code of Federal Regulations, 2014 CFR
2014-10-01
... ARRANGEMENT Drainage and Watertight Integrity of Weather Decks § 116.1110 Drainage of flush deck vessels. (a) Except as provided in paragraph (b) of this section, the weather deck on a flush deck vessel must be...
46 CFR 178.410 - Drainage of flush deck vessels.
Code of Federal Regulations, 2013 CFR
2013-10-01
... TONS) INTACT STABILITY AND SEAWORTHINESS Drainage of Weather Decks § 178.410 Drainage of flush deck vessels. (a) Except as provided in paragraph (b) of this section, the weather deck on a flush deck vessel...
46 CFR 178.410 - Drainage of flush deck vessels.
Code of Federal Regulations, 2014 CFR
2014-10-01
... TONS) INTACT STABILITY AND SEAWORTHINESS Drainage of Weather Decks § 178.410 Drainage of flush deck vessels. (a) Except as provided in paragraph (b) of this section, the weather deck on a flush deck vessel...
46 CFR 116.1110 - Drainage of flush deck vessels.
Code of Federal Regulations, 2010 CFR
2010-10-01
... ARRANGEMENT Drainage and Watertight Integrity of Weather Decks § 116.1110 Drainage of flush deck vessels. (a) Except as provided in paragraph (b) of this section, the weather deck on a flush deck vessel must be...
46 CFR 178.410 - Drainage of flush deck vessels.
Code of Federal Regulations, 2010 CFR
2010-10-01
... TONS) INTACT STABILITY AND SEAWORTHINESS Drainage of Weather Decks § 178.410 Drainage of flush deck vessels. (a) Except as provided in paragraph (b) of this section, the weather deck on a flush deck vessel...
Drug residues recovered in feed after various feedlot mixer truck cleanout procedures.
Van Donkersgoed, Joyce; Sit, Dan; Gibbons, Nicole; Ramogida, Caterina; Hendrick, Steve
2010-01-01
A study was conducted to determine the effectiveness of two methods of equipment cleanout, sequencing or flushing, for reducing drug carryover in feedlot mixer trucks. Feed samples were collected from total mixed rations before and after various feed mixer equipment cleanout procedures. Medicated rations contained either 11 ppm of tylosin or 166 or 331 ppm of chlortetracycline. There were no differences between sequencing and flushing or between flushing with dry barley and flushing with barley silage in the median proportion of drug recovered in the next ration. A larger drug reduction was achieved using flush material at a volume of 10 versus 5% of the mixer capacity and mixing the flush material for 3 versus 4 min. Regardless of the drug or prescription concentrations in the total mixed rations or the equipment cleanout procedure used, concentrations of chlortetracycline and tylosin recovered were very low.
Resistance training for hot flushes in postmenopausal women: Randomized controlled trial protocol.
Berin, Emilia; Hammar, Mats L; Lindblom, Hanna; Lindh-Åstrand, Lotta; Spetz Holm, Anna-Clara E
2016-03-01
Hot flushes and night sweats affect 75% of all women after menopause and is a common reason for decreased quality of life in mid-aged women. Hormone therapy is effective in ameliorating symptoms but cannot be used by all women due to contraindications and side effects. Engagement in regular exercise is associated with fewer hot flushes in observational studies, but aerobic exercise has not proven effective in randomized controlled trials. It remains to be determined whether resistance training is effective in reducing hot flushes and improves quality of life in symptomatic postmenopausal women. The aim of this study is to investigate the effect of standardized resistance training on hot flushes and other health parameters in postmenopausal women. This is an open, parallel-group, randomized controlled intervention study conducted in Linköping, Sweden. Sixty symptomatic and sedentary postmenopausal women with a mean of at least four moderate to severe hot flushes per day or 28 per week will be randomized to an exercise intervention or unchanged physical activity (control group). The intervention consists of 15 weeks of standardized resistance training performed three times a week under supervision of a physiotherapist. The primary outcome is hot flush frequency assessed by self-reported hot flush diaries, and the difference in change from baseline to week 15 will be compared between the intervention group and the control group. The intention is that this trial will contribute to the evidence base regarding effective treatment for hot flushes. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Chlormadinone acetate is effective for hot flush during androgen deprivation therapy
Koike, Hidekazu; Morikawa, Yasuyuki; Matsui, Hiroshi; Shibata, Yasuhiro; Ito, Kazuto; Suzuki, Kazuhiro
2013-01-01
Purpose: To investigate the clinical efficacy of low-dose chlormadinone acetate (CMA) in prostate cancer patients who suffer from hot flushes that is a major side effect of androgen deprivation therapy. Methods: Our study included 32 prostate cancer patients who had severe hot flush after undergoing hormone therapy for more than 3 months. The average age of the patients was 72.5 years. In the beginning, patients received CMA at 100 mg orally per day. We defined the hot flush as disappeared, improved, or not improved. In patients with disappeared or improved symptoms, we decreased CMA dose to 50 mg per day, and after we reevaluated the effect, we decreased CMA dose to 25 mg per day. When hot flush appeared again at 25 mg per day, we returned the dose of CMA to 50 mg per day. In cases with no change for more than two months, we canceled the treatment of CMA. Results: Hot flush disappeared in 17 patients, improved in 10 patients, and did not improve in 5 patients (reduction in 84% of hot flush patients). The median time to hot flush reduction was 1.16 months. The effect of CMA was maintained at 25 mg per day in 19 patients and at 50 mg per day in 8 patients. No patients had prostate-specific antigen failure in the treatment of CMA. Conclusions: When hot flush appears during treatment with luteinizing hormone-releasing hormone agonist for prostate cancer, it seems that CMA can improve it immediately in most patients. PMID:24223412
46 CFR 171.140 - Drainage of a flush deck vessel.
Code of Federal Regulations, 2014 CFR
2014-10-01
... PERTAINING TO VESSELS CARRYING PASSENGERS Drainage of Weather Decks § 171.140 Drainage of a flush deck vessel. (a) Except as provided in paragraph (b) of this section, the weather deck on a flush deck vessel must...
46 CFR 171.140 - Drainage of a flush deck vessel.
Code of Federal Regulations, 2010 CFR
2010-10-01
... PERTAINING TO VESSELS CARRYING PASSENGERS Drainage of Weather Decks § 171.140 Drainage of a flush deck vessel. (a) Except as provided in paragraph (b) of this section, the weather deck on a flush deck vessel must...
46 CFR 171.140 - Drainage of a flush deck vessel.
Code of Federal Regulations, 2013 CFR
2013-10-01
... PERTAINING TO VESSELS CARRYING PASSENGERS Drainage of Weather Decks § 171.140 Drainage of a flush deck vessel. (a) Except as provided in paragraph (b) of this section, the weather deck on a flush deck vessel must...
46 CFR 171.140 - Drainage of a flush deck vessel.
Code of Federal Regulations, 2012 CFR
2012-10-01
... PERTAINING TO VESSELS CARRYING PASSENGERS Drainage of Weather Decks § 171.140 Drainage of a flush deck vessel. (a) Except as provided in paragraph (b) of this section, the weather deck on a flush deck vessel must...
46 CFR 171.140 - Drainage of a flush deck vessel.
Code of Federal Regulations, 2011 CFR
2011-10-01
... PERTAINING TO VESSELS CARRYING PASSENGERS Drainage of Weather Decks § 171.140 Drainage of a flush deck vessel. (a) Except as provided in paragraph (b) of this section, the weather deck on a flush deck vessel must...
Simulation and video animation of canal flushing created by a tide gate
Schoellhamer, David H.
1988-01-01
A tide-gate algorithm was added to a one-dimensional unsteady flow model that was calibrated, verified, and used to determine the locations of as many as five tide gates that would maximize flushing in two canal systems. Results from the flow model were used to run a branched Lagrangian transport model to simulate the flushing of a conservative constituent from the canal systems both with and without tide gates. A tide gate produces a part-time riverine flow through the canal system that improves flushing along the flow path created by the tide gate. Flushing with no tide gates and with a single optimally located tide gate are shown with a video animation.
Suchomel, Miranda; Diab-Elschahawi, Magda; Kundi, Michael; Assadian, Ojan
2013-08-30
Non-touch fittings have been reported to be susceptible for Pseudomonas aeruginosa accumulation. A number of factors may contribute to this, including the frequency of usage, duration of water stagnation, or presence of plastic materials. Programmable non-touch fittings are appearing which allow regular automated post-flushing with cold water to prevent water stagnation. However, the ideal duration of post-flushing is unknown as well as the effect of pre-rinsing with cold water before use. Eight non-touch fittings with brass valve blocks were mounted on a mobile test sink and connected to the same central water pipe source, differing only in presence or absence of water connection pipes, length of connection pipe, frequency of usage, and time intervals for pre- and post-usage water flush. The total bacteria colony-forming unit (cfu) counts were obtained by the spread plate technique. Low frequency of water use in combination with a long stagnating water column resulted in high bacterial cfu counts. Post-usage flushing for 2 seconds did not differ from no flushing. Flushing for 10 seconds with cold water after use or 30 seconds flush before use were both the most effective measures to prevent non-touch fittings from biofilm formation over a period of 20 weeks. Further improvements in water fitting technology could possibly solve the problem of bacterial water contamination in health care settings.
Whelton, Andrew J; McMillan, LaKia; Connell, Matt; Kelley, Keven M; Gill, Jeff P; White, Kevin D; Gupta, Rahul; Dey, Rajarshi; Novy, Caroline
2015-01-20
During January 2014, an industrial solvent contaminated West Virginia’s Elk River and 15% of the state population’s tap water. A rapid in-home survey and water testing was conducted 2 weeks following the spill to understand resident perceptions, tap water chemical levels, and premise plumbing flushing effectiveness. Water odors were detected in all 10 homes sampled before and after premise plumbing flushing. Survey and medical data indicated flushing caused adverse health impacts. Bench-scale experiments and physiochemical property predictions showed flushing promoted chemical volatilization, and contaminants did not appreciably sorb into cross-linked polyethylene (PEX) pipe. Flushing reduced tap water 4-methylcyclohexanemethanol (4-MCHM) concentrations within some but not all homes. 4-MCHM was detected at unflushed (<10 to 420 μg/L) and flushed plumbing systems (<10 to 96 μg/L) and sometimes concentrations differed among faucets within each home. All waters contained less 4-MCHM than the 1000 μg/L Centers for Disease Control drinking water limit, but one home exceeded the 120 μg/L drinking water limit established by independent toxicologists. Nearly all households refused to resume water use activities after flushing because of water safety concerns. Science based flushing protocols should be developed to expedite recovery, minimize health impacts, and reduce concentrations in homes when future events occur.
Vithanage, M; Engesgaard, P; Jensen, K H; Illangasekare, T H; Obeysekera, J
2012-08-01
This intermediate scale laboratory experimental study was designed to improve the conceptual understanding of aquifer flushing time associated with diffuse saltwater contamination of coastal aquifers due to a tsunami-like event. The motivation comes from field observations made after the tsunami in December, 2004 in South Asia. The focus is on the role and effects of heterogeneity on flushing effectiveness. A scheme that combines experimentation in a 4.8m long laboratory tank and numerical modeling was used. To demonstrate the effects of geologic heterogeneity, plume migration and flushing times were analyzed in both homogeneous and layered media and under different boundary conditions (ambient flow, saltwater infiltration rate, freshwater recharge). Saltwater and freshwater infiltrations imitate the results of the groundwater salinization from the tsunami and freshening from the monsoon rainfall. The saltwater plume behavior was monitored both through visual observations (digital photography) of the dyed salt water and using measurements taken from several electrical conductivity sensors installed through the tank walls. The variable-density, three dimensional code HST3D was used to simulate the tank experiments and understand the fate and movement of the saltwater plume under field conditions. The results from the tank experiments and modeling demonstrated that macro-scale heterogeneity significantly influenced the migration patterns and flushing times of diffuse saltwater contamination. Ambient flow had a direct influence on total flush-out time, and heterogeneity impacted flush-out times for the top part of the tank and total flush-out times. The presence of a continuous low-permeability layer caused a 40% increase in complete flush-out time due to the slower flow of salt water in the low-permeability layer. When a relatively small opening was introduced in the low-permeability layer, salt water migrated quickly into a higher-permeable layer below causing a reduction in flush-out time. Freshwater recharge caused an early dilution of salt water in the top part of the tank in the case of a layered media, but also pushed the saltwater plume into the low-permeability layer which led to increased total flush-out times. Copyright © 2012 Elsevier B.V. All rights reserved.
ENGINEERING BULLETIN: IN SITU SOIL FLUSHING
In situ soil flushing is the extraction of contaminants from the soil with water or other suitable aqueous solutions. Soil flushing is accomplished by passing the extraction fluid through in-place soils using an injection or infiltration process. Extraction fluids must be recover...
Pinkerton, JoAnn V; Bushmakin, Andrew G; Bobula, Joel; Lavenberg, Joanne; Komm, Barry S; Abraham, Lucy
2017-12-01
To evaluate the impact of baseline hot flush frequency and severity on time to symptom improvement during treatment with conjugated estrogens/bazedoxifene (CE/BZA). Data were pooled through week 12 from two randomized placebo-controlled trials (SMART-1 and SMART-2) of nonhysterectomized postmenopausal women with hot flushes treated with CE 0.45 mg/BZA 20 mg or CE 0.625 mg/BZA 20 mg. Time to transient and stable improvement (≥ 50% reduction in hot flush frequency/severity) was estimated using nonparametric models. Transient improvement in hot flush frequency occurred earlier in women treated with CE 0.45 mg/BZA 20 mg with less frequent versus more frequent baseline hot flushes per day: median time to transient improvement was 2, 7, and 11 days for women with < 3, 3 to < 8, and ≥ 8 hot flushes per day at baseline, respectively (P = 0.0009). Transient improvement in severity occurred earlier for women with less severe versus more severe baseline hot flushes: median time to transient improvement was 2, 6, and 16 days for women with mild, moderate, and severe hot flushes at baseline, respectively (P < 0.0001). Stable improvement typically occurred 2 to 3 days after the transient event and was less influenced by baseline status. A similar pattern was observed with CE 0.625 mg/BZA 20 mg treatment, though improvement occurred a few days earlier than with CE 0.45 mg/BZA 20 mg. Women with more frequent/severe hot flushes take longer to achieve transient improvements with CE/BZA and should be encouraged to continue treatment, as it may take longer than a few weeks to achieve significant improvement.
Tidal flushing time of marine fish culture zones in Hong Kong
NASA Astrophysics Data System (ADS)
Mao, Jing-Qiao; Wong, Ken T. M.; Lee, Joseph H. W.; Choi, K. W.
2011-12-01
Accurate determination of flushing time is crucial for maintaining sustainable production in fish culture zones (FCZs), as it represents the physical self-purification capability via tidal exchange with clean water in the outer sea. However, owing to the temporal and spatial complexity of the coastal flushing process, existing methods for determining flushing time may not be generally applicable. In this paper, a systematic method for determining the flushing time in FCZs is presented, in which bathymetry, runoff, tidal range and stratification are properly accounted for. We determine the flushing time via numerical tracer experiments, using robust 3D hydrodynamic and mass transport models. For FCZs located in sheltered and land-locked tidal inlets, the system boundary can be naturally defined at the connection with the open sea. For FCZs located in open waters, hydrodynamic tracking is first used to assess the extent of tidal excursion and thus delimit the initial boundary between clean water and polluted water. This general method is applied to all designated marine FCZs in Hong Kong for both the dry and wet seasons, including 20 sheltered FCZs (in semi-enclosed waters of Tolo Harbour, Mirs Bay, and Port Shelter) and 6 FCZs in open waters. Our results show that flushing time is the longest in inner Port Shelter (about 40 days in dry season), and the shortest for the FCZs in open waters (less than one week in dry season). In addition, the flushing time in dry season is commonly longer than that in wet season: 20%˜40% for most well-sheltered FCZs; 2.6˜4 times for the others. Our results indicate a positive correlation between the flushing time and distance to open boundary, supporting the view that the flushing time of a FCZ is closely related to its location. This study provides a solid basis for mariculture management such as the determination of carrying capacity of FCZs.
Assessment of hot flushes and vaginal dryness among obese women undergoing bariatric surgery.
Goughnour, S L; Thurston, R C; Althouse, A D; Freese, K E; Edwards, R P; Hamad, G G; McCloskey, C; Ramanathan, R; Bovbjerg, D H; Linkov, F
2016-01-01
Menopausal symptoms are associated with a negative impact on the quality of life, leading women to seek medical treatment. Obesity has been linked to higher levels of menopausal symptoms such as hot flushes. This assessment will explore whether the prevalence and bother of hot flushes and vaginal dryness change from pre- to post-bariatric surgery among obese midlife women. This study is a longitudinal analysis of data from 69 women (ages 35-72 years) undergoing bariatric surgery with reported reproductive histories and menopausal symptoms at preoperative and 6-month postoperative visits. Prevalence of and degree of bother of hot flushes and vaginal dryness at pre- and post-surgery were compared using McNemar's test and Wilcoxon signed-rank test. The reported degree of bother of symptoms associated with hot flushes decreased from pre- to post-surgery (p < 0.01). There was no significant change in the prevalence of hot flushes or vaginal dryness in the overall study sample. The degree of bother of symptoms associated with hot flushes among midlife women may decrease after bariatric surgery. These results highlight important secondary gains, including less bothersome menopausal symptoms, for women who choose bariatric surgery for weight loss.
Citrus flush shoot ontogeny modulates biotic potential of Diaphorina citri.
Cifuentes-Arenas, Juan Camilo; de Goes, António; de Miranda, Marcelo Pedreira; Beattie, George Andrew Charles; Lopes, Silvio Aparecido
2018-01-01
The biology and behaviour of the psyllid Diaphorina citri Kuwayama (Hemiptera: Sternorrhyncha: Liviidae), the major insect vector of bacteria associated with huanglongbing, have been extensively studied with respect to host preferences, thermal requirements, and responses to visual and chemical volatile stimuli. However, development of the psyllid in relation to the ontogeny of immature citrus flush growth has not been clearly defined or illustrated. Such information is important for determining the timing and frequency of measures used to minimize populations of the psyllid in orchards and spread of HLB. Our objective was to study how flush ontogeny influences the biotic potential of the psyllid. We divided citrus flush growth into six stages within four developmental phases: emergence (V1), development (V2 and V3), maturation (V4 and V5), and dormancy (V6). Diaphorina citri oviposition and nymph development were assessed on all flush stages in a temperature controlled room, and in a screen-house in which ambient temperatures varied. Our results show that biotic potential of Diaphorina citri is not a matter of the size or the age of the flushes (days after budbreak), but the developmental stage within its ontogeny. Females laid eggs on flush V1 to V5 only, with the time needed to commence oviposition increasing with the increasing in flush age. Stages V1, V2 and V3 were most suitable for oviposition, nymph survival and development, and adult emergence, which showed evidence of protandry. Flush shoots at emerging and developmental phases should be the focus of any chemical or biological control strategy to reduce the biotic potential of D. citri, to protect citrus tree from Liberibacter infection and to minimize HLB dissemination.
Citrus flush shoot ontogeny modulates biotic potential of Diaphorina citri
de Goes, António; de Miranda, Marcelo Pedreira
2018-01-01
The biology and behaviour of the psyllid Diaphorina citri Kuwayama (Hemiptera: Sternorrhyncha: Liviidae), the major insect vector of bacteria associated with huanglongbing, have been extensively studied with respect to host preferences, thermal requirements, and responses to visual and chemical volatile stimuli. However, development of the psyllid in relation to the ontogeny of immature citrus flush growth has not been clearly defined or illustrated. Such information is important for determining the timing and frequency of measures used to minimize populations of the psyllid in orchards and spread of HLB. Our objective was to study how flush ontogeny influences the biotic potential of the psyllid. We divided citrus flush growth into six stages within four developmental phases: emergence (V1), development (V2 and V3), maturation (V4 and V5), and dormancy (V6). Diaphorina citri oviposition and nymph development were assessed on all flush stages in a temperature controlled room, and in a screen-house in which ambient temperatures varied. Our results show that biotic potential of Diaphorina citri is not a matter of the size or the age of the flushes (days after budbreak), but the developmental stage within its ontogeny. Females laid eggs on flush V1 to V5 only, with the time needed to commence oviposition increasing with the increasing in flush age. Stages V1, V2 and V3 were most suitable for oviposition, nymph survival and development, and adult emergence, which showed evidence of protandry. Flush shoots at emerging and developmental phases should be the focus of any chemical or biological control strategy to reduce the biotic potential of D. citri, to protect citrus tree from Liberibacter infection and to minimize HLB dissemination. PMID:29304052
A comparison of basal and eye-flush tears for the analysis of cat tear proteins.
Petznick, Andrea; Evans, Margaret D M; Madigan, Michele C; Markoulli, Maria; Garrett, Qian; Sweeney, Deborah F
2011-02-01
To identify a rapid and effective tear collection method providing sufficient tear volume and total protein content (TPC) for analysis of individual proteins in cats. Domestic adult short-haired cats (12-37 months; 2.7-6.6 kg) were used in the study. Basal tears without stimulation and eye-flush tears after instillation of saline (10 μl) were collected using microcapillary tubes from animal eyes either unwounded control or wounded with 9-mm central epithelial debridement giving four groups with n = 3. Tear comparisons were based on total time and rate for tear collection, TPC using micro bicinchoninic acid (BCA), tear immunoglobulin A (IgA), total matrix-metalloproteinase (MMP)-9 concentration using sandwich enzyme-linked immunosorbent assay (ELISA) and MMP-9 activity. Eye-flush tears were collected significantly faster than basal tears in wounded eyes with higher rates for tear collection in unwounded control and wounded eyes. TPC was significantly lower in eye-flush tears compared to basal tears. The relative proportion of tear IgA normalized to TPC (% IgA of TPC) was not significantly different between basal and eye-flush tears. In unwounded control eyes, MMP-9 was slightly higher in eye-flush than in basal tears; activity of MMP-9 in both tear types was similar. In wounded eyes, eye-flush tears showed highest MMP-9 levels and activity on Day 1, which subsequently decreased to Day 7. MMP-9 activity in basal tears from wounded eyes did not display changes in expression. Eye-flush tears can be collected rapidly providing sufficient tear volume and TPC. This study also indicates that eye-flush tears may be more suitable than basal tears for the analysis of MMPs following corneal wounding. © 2011 The Authors. Acta Ophthalmologica © 2011 Acta Ophthalmologica Scandinavica Foundation.
Microbiological Hazards of Household Toilets: Droplet Production and the Fate of Residual Organisms
Gerba, Charles P.; Wallis, Craig; Melnick, Joseph L.
1975-01-01
Large numbers of bacteria and viruses when seeded into household toilets were shown to remain in the bowl after flushing, and even continual flushing could not remove a persistent fraction. This was found to be due to the adsorption of the organisms to the porcelain surfaces of the bowl, with gradual elution occurring after each flush. Droplets produced by flushing toilets were found to harbor both bacteria and viruses which had been seeded. The detection of bacteria and viruses falling out onto surfaces in bathrooms after flushing indicated that they remain airborne long enough to settle on surface throughout the bathroom. Thus, there is a possibility that a person may acquire an infection from an aerosol produced by a toilet. PMID:169732
The flushing time of an estuary is generally defined as the turnover time of fresh water in the estuary, that is, the time required to replace the fresh water contained in the estuary with freshwater inflow. Thus, the flushing time of an estuary is the ratio of the volume of fres...
21 CFR 870.1210 - Continuous flush catheter.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Continuous flush catheter. 870.1210 Section 870.1210 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1210 Continuous flush...
21 CFR 870.1210 - Continuous flush catheter.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Continuous flush catheter. 870.1210 Section 870.1210 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1210 Continuous flush...
40 CFR 141.804 - Aircraft water system operations and maintenance plan.
Code of Federal Regulations, 2013 CFR
2013-07-01
... must include the following requirements for procedures for disinfection and flushing of aircraft water system. (i) The air carrier must conduct disinfection and flushing of the aircraft water system in... water procedures; (ii) Sample collection procedures; (iii) Disinfection and flushing procedures; (iv...
The pharmacological and hormonal therapy of hot flushes in breast cancer survivors.
Wiśniewska, Iwona; Jochymek, Bożena; Lenart-Lipińska, Monika; Chabowski, Mariusz
2016-03-01
The side effects of oncological treatment, which appear during or after therapy, are sometimes very annoying for patients and are not adequately treated by physicians. Among the symptoms experienced by breast cancer patients are hot flushes, which result from a natural or cancer therapy-induced menopause. The intensity of hot flushes in breast cancer patients may be more severe than those experienced by women undergoing a natural menopause. Taking into account the incidence of breast cancer and long-lasting hormone-suppression therapies, the problem of hot flushes will affect many women. Hormonal replacement therapy, the most effective therapeutic means for alleviating hot flushes, is usually contraindicated for breast cancer patients. For intense and severe hot flushes, pharmacological treatment using agents from a group of selective serotonin reuptake inhibitors and serotonin and norepinephrine reuptake inhibitors such as venlafaxine or citalopram may be introduced. Other agents from different pharmacological groups, such as clonidine, gabapentin, or pregabalin, have also proved to be effective in treating hot flushes. The efficacy of phytoestrogens has not been proven in randomized clinical trials. The importance of the placebo effect in decreasing vasomotor symptoms has also been reported in many research papers. Educating breast cancer patients in lifestyle changes which decrease the frequency and intensity of vasomotor symptoms can offer significant help too. This paper reviews the current state of research in order to assess the options for the treatment of hot flushes in breast cancer survivors.
Managing Hot Flushes in Menopausal Women: A Review.
Mallhi, Tauqeer Hussain; Khan, Yusra Habib; Khan, Amer Hayat; Mahmood, Qaisar; Khalid, Syed Haroon; Saleem, Mohammad
2018-06-01
Hot flushes during menopause are distressing for women and result in poor quality of life. Purpose of the current review was to evaluate the available treatment modalities that should be utilised for the management of hot flushes. Menopause refers to last menses of women life and can be declared after amenorrhea of 12 months. Vasomotor symptoms including hot flushes and night sweats are common after menopause, affecting almost 50 - 85% women older than 45 years. The mean increment in core body and skin temperature is 0.5°C and 0.25 - 3°C during a hot flush attack. Low level of estrogen during menopause and its association in triggering episodes of hot flushes, is still under debate. The most accepted hypothesis is a narrowing of the thermoneutral zone (TNZ) triggered by estrogen fluctuations. Although, hormone replacement therapy (HRT) remains the standard treatment for the alleviation of such symptoms, incidence of life threatening side effects restrained medical professionals from its use. Complications associated with the use of HRT can be avoided by appropriate evaluation of patients before initiating therapy. Several guidelines have also recommended HRT (estrogen and progesterone) to be safe for up to a period of seven years. Both hormonal and non-hormonal treatments are used for the management of hot flushes. Since hot flushes are the least appreciated and neglected complication of menopause, current review provides detailed information on its background, pathophysiology and management, and emphasises the need of its treatment.
NASA Astrophysics Data System (ADS)
Ocampo, Carlos J.; Oldham, Carolyn E.; Sivapalan, Murugesu; Turner, Jeffrey V.
2006-12-01
Deciphering the connection between streamflows and nitrate (NO-3) discharge requires identification of the various water flow pathways within a catchment, and the different time-scales at which hydrological and biogeochemical processes occur. Despite the complexity of the processes involved, many catchments around the world present a characteristic flushing response of NO-3 export. Yet the controls on the flushing response, and how they vary across space and time, are still not clearly understood. In this paper, the flushing response of NO-3 export from a rural catchment in Western Australia was investigated using isotopic (deuterium), chemical (chloride, NO-3), and hydrometric data across different antecedent conditions and time-scales. The catchment streamflow was at all time-scales dominated by a pre-event water source, and the NO-3 discharge was correlated with the magnitude of areas contributing to saturation overland flow. The NO-3 discharge also appeared related to the shallow groundwater dynamics. Thus, the antecedent moisture condition of the catchment at seasonal and interannual time-scales had a major impact on the NO-3 flushing response. In particular, the dynamics of the shallow ephemeral perched aquifer drove a shift from hydrological controls on NO-3 discharge during the early flushing stage to an apparent biogeochemical control on NO-3 discharge during the steady decline stage of the flushing response. This temporally variable control hypothesis provides a new and alternative description of the mechanisms behind the commonly seen flushing response. Copyright
Effect of lavender aromatherapy on menopause hot flushing: A crossover randomized clinical trial.
Kazemzadeh, Rafat; Nikjou, Roya; Rostamnegad, Masoumeh; Norouzi, Hosein
2016-09-01
Flushing is generally considered to be the primary symptom of menopause and is typically the most common complaint in menopausal women. Although flushing poses no danger to a woman's health, it decreases the quality of life. Thus, the purpose of this study was to determine the effect of lavender aromatherapy on menopause flushing. This double-blinded crossover clinical trial included 100 menopausal women 45-55 years of age who were referred to various health centers in Ardabil, Iran in 2013-2014. Samples were blocked randomly and divided into two intervention (lavender) and control (diluted milk) groups. Lavender aroma was smelled for 20 minutes twice a day, over a 12-week period. Data were collected using a demographic questionnaire, and flushing numbers were duly recorded. Data analysis was performed by SPSS version 16 (SPSS Inc., Chicago, IL, USA) using the Chi-square and t test. The results of our investigation showed that both groups had no significant difference according to demographic characteristics (p > 0.05). Additionally, the flushing number significantly decreased in the intervention group than in the control group (p < 0.001). This study indicated that the use of lavender aromatherapy reduced menopause flushing. Given the impact of stress on flushing and the undesirable effects of menopause symptoms on the quality of life, it would appear that this simple, noninvasive, safe, and effective method can be used by menopausal women with noticeable benefits. Copyright © 2016. Published by Elsevier Taiwan LLC.
46 CFR 194.15-11 - Flushing systems.
Code of Federal Regulations, 2012 CFR
2012-10-01
..., AND CONTROL OF EXPLOSIVES AND OTHER HAZARDOUS MATERIALS Chemistry Laboratory and Scientific Laboratory § 194.15-11 Flushing systems. (a) Working spaces in which chemical stores are used shall be equipped with a fresh water supply shower. (b) There shall be a provision for flushing away chemical spills. ...
46 CFR 194.15-11 - Flushing systems.
Code of Federal Regulations, 2014 CFR
2014-10-01
..., AND CONTROL OF EXPLOSIVES AND OTHER HAZARDOUS MATERIALS Chemistry Laboratory and Scientific Laboratory § 194.15-11 Flushing systems. (a) Working spaces in which chemical stores are used shall be equipped with a fresh water supply shower. (b) There shall be a provision for flushing away chemical spills. ...
46 CFR 194.15-11 - Flushing systems.
Code of Federal Regulations, 2011 CFR
2011-10-01
..., AND CONTROL OF EXPLOSIVES AND OTHER HAZARDOUS MATERIALS Chemistry Laboratory and Scientific Laboratory § 194.15-11 Flushing systems. (a) Working spaces in which chemical stores are used shall be equipped with a fresh water supply shower. (b) There shall be a provision for flushing away chemical spills. ...
Automatic Flushing Unit With Cleanliness Monitor
NASA Technical Reports Server (NTRS)
Hildebrandt, N. E.
1982-01-01
Liquid-level probe kept clean, therefore at peak accuracy, by unit that flushes probe with solvent, monitors effluent for contamination, and determines probe is particle-free. Approach may be adaptable to industrial cleaning such as flushing filters and pipes, and ensuring that manufactured parts have been adequately cleaned.
30 CFR 71.400 - Bathing facilities; change rooms; sanitary flush toilet facilities.
Code of Federal Regulations, 2012 CFR
2012-07-01
... WORK AREAS OF UNDERGROUND COAL MINES Surface Bathing Facilities, Change Rooms, and Sanitary Flush Toilet Facilities at Surface Coal Mines § 71.400 Bathing facilities; change rooms; sanitary flush toilet... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Bathing facilities; change rooms; sanitary...
30 CFR 71.400 - Bathing facilities; change rooms; sanitary flush toilet facilities.
Code of Federal Regulations, 2013 CFR
2013-07-01
... WORK AREAS OF UNDERGROUND COAL MINES Surface Bathing Facilities, Change Rooms, and Sanitary Flush Toilet Facilities at Surface Coal Mines § 71.400 Bathing facilities; change rooms; sanitary flush toilet... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Bathing facilities; change rooms; sanitary...
30 CFR 71.400 - Bathing facilities; change rooms; sanitary flush toilet facilities.
Code of Federal Regulations, 2014 CFR
2014-07-01
... WORK AREAS OF UNDERGROUND COAL MINES Surface Bathing Facilities, Change Rooms, and Sanitary Flush Toilet Facilities at Surface Coal Mines § 71.400 Bathing facilities; change rooms; sanitary flush toilet... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Bathing facilities; change rooms; sanitary...
30 CFR 71.400 - Bathing facilities; change rooms; sanitary flush toilet facilities.
Code of Federal Regulations, 2011 CFR
2011-07-01
... WORK AREAS OF UNDERGROUND COAL MINES Surface Bathing Facilities, Change Rooms, and Sanitary Flush Toilet Facilities at Surface Coal Mines § 71.400 Bathing facilities; change rooms; sanitary flush toilet... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Bathing facilities; change rooms; sanitary...
GATE AND VACUUM FLUSHING OF SEWER SEDIMENT: LABORATORY TESTING
The objective of this study was to test the performance of a traditional gate-flushing device and a newly-designed vacuum-flushing device in removing sediment from combined sewers and CSO storage tanks. A laboratory hydraulic flume was used to simulate a reach of sewer or storag...
30 CFR 56.7807 - Flushing the combustion chamber.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Flushing the combustion chamber. 56.7807 Section 56.7807 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND... Rotary Jet Piercing Rotary Jet Piercing § 56.7807 Flushing the combustion chamber. The combustion chamber...
30 CFR 56.7807 - Flushing the combustion chamber.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Flushing the combustion chamber. 56.7807 Section 56.7807 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND... Rotary Jet Piercing Rotary Jet Piercing § 56.7807 Flushing the combustion chamber. The combustion chamber...
30 CFR 56.7807 - Flushing the combustion chamber.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Flushing the combustion chamber. 56.7807 Section 56.7807 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND... Rotary Jet Piercing Rotary Jet Piercing § 56.7807 Flushing the combustion chamber. The combustion chamber...
This research study included an extensive literature review on existing sewer sediment flushing technologies. An innovative vacuum flush system previously developed by the U.S. EPA was tested under laboratory conditions. The tests revealed a strong correlation between the strengt...
A pilot-scale field experiment was conducted to compare the remediation effectiveness of an enhanced-solubilization technique to that of water flushing for removal of multicomponent nonaqueous-phase organic liquid (NAPL) contaminants form a phreatic aquifer. This innovative remed...
SEWER SEDIMENT GATE AND VACUUM FLUSHING TANKS: LABORATORY FLUME STUDIES
The objective of this study was to test the performance of a traditional gate-flushing device and a newly designed vacuum-flushing device in removing sediments from combined sewers and CSO storage tanks. A laboratory hydraulic flune was used to simulate a reach of sewer or storag...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Maienschein, J.L.; Garcia, F.; Garza, R.G.
Tritium-handling apparatus has been decontaminated as part of the downsizing of the LLNL Tritium Facility. Two stainless-steel glove boxes that had been used to process lithium deuteride-tritide (LiDT) slat were decontaminated using the Portable Cleanup System so that they could be flushed with room air through the facility ventilation system. In this paper the details on the decontamination operation are provided. A series of metal (palladium and vanadium) hydride storage beds have been drained of tritium and flushed with deuterium, in order to remove as much tritium as possible. The bed draining and flushing procedure is described, and a calculationalmore » method is presented which allows estimation of the tritium remaining in a bed after it has been drained and flushed. Data on specific bed draining and flushing are given.« less
Stevens, R B; Skorupa, J Y; Rigley, T H; Yannam, G R; Nielsen, K J; Schriner, M E; Skorupa, A J; Murante, A; Holdaway, E; Wrenshall, L E
2009-05-01
Histidine-Tryptophan-Ketoglutarate (HTK) solution is increasingly used to flush and preserve organ donor kidneys, with efficacy claimed equivalent to University of Wisconsin (UW) solution. We observed and reported increased graft pancreatitis in pancreata flushed with HTK solution, which prompted this review of transplanting HTK-flushed kidneys. We analyzed outcomes of deceased-donor kidneys flushed with HTK and UW solutions with a minimum of 12 months follow-up, excluding pediatric and multi-organ recipients. We evaluated patient and graft survival and rejection rates, variables that might constitute hazards to graft survival and renal function. Two-year patient survival, rejection, renal function and graft survival were not different, but early graft loss (<6 months) was worse in HTK-flushed kidneys (p < 0.03). A Cox analysis of donor grade, cold ischemic time, panel reactive antibodies (PRA), donor race, first vs. repeat transplant, rejection and flush solution showed that only HTK use predicted early graft loss (p < 0.04; relative risk = 3.24), almost exclusively attributable to primary non-function (HTK, n = 5 (6.30%); UW, n = 1 (0.65%); p = 0.02). Delayed graft function and early graft loss with HTK occurred only in lesser grade kidneys, suggesting it should be used with caution in marginal donors.
NASA Astrophysics Data System (ADS)
Espa, Paolo; Castelli, Elena; Crosa, Giuseppe; Gentili, Gaetano
2013-07-01
Sediment flushing may be effective in mitigating loss of reservoir storage due to siltation, but flushing must be controlled to limit the impact on the downstream environment. A reliable prediction of the environmental effects of sediment flushing is hindered by the limited scientific information currently available. Consequently, there may be some controversy as regards to management decisions, planning the work, and monitoring strategies. This paper summarizes the main results of a monitoring campaign on the stream below a small alpine hydropower reservoir subjected to annual flushing between 2006 and 2009. The removed sediment was essentially silt, and the suspended solid concentration (SSC) of the discharged water was controlled to alleviate downstream impact. Control was achieved through hydraulic regulation and mechanical digging, alternating daytime sediment evacuation, and nocturnal clear water release. The four operations lasted about two weeks each and had an average SSC of about 4 g L-1. Maximum values of SSC were generally kept below 10 g L-1. Downstream impact was quantified through sampling of fish fauna (brown trout) and macroinvertebrate in the final reach of the effluent stream. The benthic community was severely impaired by the flushing operations, but recovered to pre-flushing values in a few months. As expected, the impact on brown trout was heavier on juveniles. While data biasing due to fish removal and re-stocking cannot be ruled out, the fish community seems to have reached a state of equilibrium characterized by a lower density than was measured before the flushing operations.
Espa, Paolo; Castelli, Elena; Crosa, Giuseppe; Gentili, Gaetano
2013-07-01
Sediment flushing may be effective in mitigating loss of reservoir storage due to siltation, but flushing must be controlled to limit the impact on the downstream environment. A reliable prediction of the environmental effects of sediment flushing is hindered by the limited scientific information currently available. Consequently, there may be some controversy as regards to management decisions, planning the work, and monitoring strategies. This paper summarizes the main results of a monitoring campaign on the stream below a small alpine hydropower reservoir subjected to annual flushing between 2006 and 2009. The removed sediment was essentially silt, and the suspended solid concentration (SSC) of the discharged water was controlled to alleviate downstream impact. Control was achieved through hydraulic regulation and mechanical digging, alternating daytime sediment evacuation, and nocturnal clear water release. The four operations lasted about two weeks each and had an average SSC of about 4 g L(-1). Maximum values of SSC were generally kept below 10 g L(-1). Downstream impact was quantified through sampling of fish fauna (brown trout) and macroinvertebrate in the final reach of the effluent stream. The benthic community was severely impaired by the flushing operations, but recovered to pre-flushing values in a few months. As expected, the impact on brown trout was heavier on juveniles. While data biasing due to fish removal and re-stocking cannot be ruled out, the fish community seems to have reached a state of equilibrium characterized by a lower density than was measured before the flushing operations.
von Horn, Kyra; Depenbusch, Marion; Schultze-Mosgau, Askan; Griesinger, Georg
2017-04-01
Is a modified double-lumen aspiration needle system with follicular flushing able to increase the mean oocyte yield by at least one in poor response IVF patients as compared to single-lumen needle aspiration without flushing? Follicular flushing with the modified flushing system did not increase the number of oocytes, but increased the procedure duration. Most studies on follicular flushing were performed with conventional double-lumen needles in patients who were normal responders. Overall, these studies indicated no benefit of follicular flushing. Prospective, single-centre, randomized, controlled, open, superiority trial comparing the 17 G Steiner-Tan Needle® flushing system with a standard 17 G single-lumen aspiration needle (Gynetics®); time frame February 2015-March 2016. Eighty IVF patients, 18-45 years, BMI >18 kg/m2 to <35 kg/m2, presenting with ≤ five follicles >10 mm in both ovaries at the end of the follicular phase were randomized to either aspirating and flushing each follicle 3× with the Steiner-Tan-Needle® automated flushing system (n = 40) or a conventional single-lumen needle aspiration (n = 40). Primary outcome was the number of cumulus-oocyte-complexes (COCs). Procedure duration, burden (Depression Anxiety and Stress Scale; DASS-21) and post-procedure pain were also assessed. Flushing was not superior with a mean (SD) number of COCs of 2.4 (2.0) and 3.1 (2.3) in the Steiner-Tan Needle® and in the Gynectics® group, respectively (mean difference -0.7, 95% CI: 0.3 to -1.6; P = 0.27). Likewise no differences were observed in metaphase II oocytes, two pronuclear oocytes, number of patients having an embryo transfer and DASS 21 scores. The procedure duration was significantly 2-fold increased. Testing for differences in the number of patients achieving an embryo transfer or differences in pregnancy rate would require a much larger sample size. The use of follicular flushing is unlikely to benefit the prognosis of patients with poor ovarian response. The Steiner-Tan Needles® and the flushing system were provided for free by the manufacturer. K.v.H. has received personal fees from Finox and non-financial support from Merck-Serono; M.D. has received personal fees from Finox and non-financial support from Merck-Serono. A.S.-M. has received personal fees and non-financial support from M.D., Ferring, Merck-Serono, Finox, TEVA. G.G. has received personal fees and non-financial support from M.D., Ferring, Merck-Serono, Finox, TEVA, IBSA, Glycotope, as well as personal fees from VitroLife, NMC Healthcare LLC, ReprodWissen LLC and ZIVA LLC. NCT 02365350 (clinicaltrials.gov). Sixth of February 2015. Ninth of February 2015. © The Author 2017. Published by Oxford University Press on behalf of the European Society of Human Reproduction and Embryology. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com
REMOVAL OF TANK AND SEWER SEDIMENT BY GATE FLUSHING: COMPUTATIONAL FLUID DYNAMICS MODEL STUDIES
This presentation will discuss the application of a computational fluid dynamics 3D flow model to simulate gate flushing for removing tank/sewer sediments. The physical model of the flushing device was a tank fabricated and installed at the head-end of a hydraulic flume. The fl...
Use of a double chip seal to correct a flushing hot mix asphalt pavement in Washington State.
DOT National Transportation Integrated Search
2011-04-01
A chip seal constructed on an existing flushed roadway has the potential to result in bleeding or flushing of the new chip seal. The excess binder, if not properly accounted for during design and construction, will migrate to the surface of the chip ...
30 CFR 57.7807 - Flushing the combustion chamber.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Flushing the combustion chamber. 57.7807... and Rotary Jet Piercing Rotary Jet Piercing-Surface Only § 57.7807 Flushing the combustion chamber. The combustion chamber of a jet drill stem which has been sitting unoperated in a drill hole shall be...
30 CFR 57.7807 - Flushing the combustion chamber.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Flushing the combustion chamber. 57.7807... and Rotary Jet Piercing Rotary Jet Piercing-Surface Only § 57.7807 Flushing the combustion chamber. The combustion chamber of a jet drill stem which has been sitting unoperated in a drill hole shall be...
30 CFR 57.7807 - Flushing the combustion chamber.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Flushing the combustion chamber. 57.7807... and Rotary Jet Piercing Rotary Jet Piercing-Surface Only § 57.7807 Flushing the combustion chamber. The combustion chamber of a jet drill stem which has been sitting unoperated in a drill hole shall be...
DOT National Transportation Integrated Search
2016-09-01
A double chip seal was applied to an existing hot mix asphalt (HMA) pavement to mitigate severe flushing that existed throughout the project. Special care was taken to adjust the amount of binder used to account for the degree of flushing in the exis...
Dumas, F; Le Gendre, R; Thomas, Y; Andréfouët, S
2012-01-01
Hydrodynamic functioning and water circulation of the semi-closed deep lagoon of Ahe atoll (Tuamotu Archipelago, French Polynesia) were investigated using 1 year of field data and a 3D hydrodynamical model. Tidal amplitude averaged less than 30 cm, but tide generated very strong currents (2 ms(-1)) in the pass, creating a jet-like circulation that partitioned the lagoon into three residual circulation cells. The pass entirely flushed excess water brought by waves-induced radiation stress. Circulation patterns were computed for climatological meteorological conditions and summarized with stream function and flushing time. Lagoon hydrodynamics and general overturning circulation was driven by wind. Renewal time was 250 days, whereas the e-flushing time yielded a lagoon-wide 80-days average. Tide-driven flush through the pass and wind-driven overturning circulation designate Ahe as a wind-driven, tidally and weakly wave-flushed deep lagoon. The 3D model allows studying pearl oyster larvae dispersal in both realistic and climatological conditions for aquaculture applications. Copyright © 2012 Elsevier Ltd. All rights reserved.
On sampling biases arising from insufficient bottle flushing
NASA Astrophysics Data System (ADS)
Codispoti, L. A.; Paver, C. R.
2016-02-01
Collection of representative water samples using carousel bottles is important for accurately determining biological and chemical gradients. The development of more technologically advanced instrumentation and sampling apparatus causes sampling packages to increase and "soak times" to decrease, increasing the probability that insufficient bottle flushing will produce biased results. Qualitative evidence from various expeditions suggest that insufficient flushing may be a problem. Here we report on multiple field experiments that were conducted to better quantify the errors that can arise from insufficient bottle flushing. Our experiments suggest that soak times of more than 2 minutes are sometimes required to collect a representative sample.
Inhibition of soluble epoxide hydrolase limits niacin-induced vasodilation in mice
Inceoglu, A. B.; Clifton, H.L.; Yang, J.; Hegedus, C.; Hammock, B. D.; Schaefer, S.
2012-01-01
Background The use of niacin in the treatment of dyslipidemias is limited by the common side effect of cutaneous vasodilation, commonly termed flushing. Flushing is thought to be due to release of the vasodilatory prostanoids PGD2 and PGE2 from arachidonic acid metabolism through the cyclooxygenase (COX) pathway. Arachidonic acid is also metabolized by the cytochrome P450 system which is regulated, in part, by the enzyme soluble epoxide hydrolase (sEH). Methods: These experiments used an established murine model in which ear tissue perfusion was measured by laser Doppler to test the hypothesis that inhibition of sEH would limit niacin-induced flushing. Results: Niacin-induced flushing was reduced from 506 ± 126 to 213 ± 39 % in sEH knockout animals. Pharmacologic treatment with 3 structurally distinct sEH inhibitors similarly reduced flushing in a dose dependent manner, with maximal reduction to 143±15% of baseline flow using a concentration of 1 mg/kg TPAU (1-trifluoromethoxyphenyl-3-(1-acetylpiperidin-4-yl) urea). Systemically administered PGD2 caused ear vasodilation which was not changed by either pharmacologic sEH inhibition or by sEH gene deletion. Conclusions: Inhibition of sEH markedly reduces niacin-induced flushing in this model without an apparent effect on the response to PGD2. sEH inhibition may be a new therapeutic approach to limit flushing in humans. PMID:22526297
Newman, Ian M; Ding, Lanyan; Shell, Duane F; Lin, Lida
2017-06-09
Alcohol-related facial flushing is a sign of compromised alcohol metabolism and increased risk of certain cancers. This project examined how facial flushing might be used to reduce alcohol use to lower cancer risks. Interviews with Chinese university students identified gender, friendship, and drinking purpose as important variables related to whether someone would encourage a person who flushes when drinking alcohol to stop or reduce their drinking. A questionnaire was developed that incorporated these variables into 24 drinking scenarios in which someone flushed while drinking. Students responded whether they would (a) encourage the flusher to stop or drink less; (b) do nothing while wishing they could; or (c) do nothing because there was no need. Analysis of survey responses from 2912 university students showed a three-way interaction of the variables and implied that the probability students will intervene when a drinker flushes was highest when the flusher was a female, a close friend, and the drinking purpose was for fun and lowest if the flusher was a male, the friendship was general, and the drinking purpose was risky. The results provide important details about the social factors affecting how other people respond to a person who flushes when drinking alcohol. This information is useful for those considering ways to reduce and prevent aerodigestive cancers through education and information programs.
A traditional first flush assessment of E. coli in urban stormwater runoff.
McCarthy, D T
2009-01-01
The behaviour of microorganisms in urban stormwater should be thoroughly investigated and understood to (a) design treatment technologies that can reduce the human health risks of utilising stormwater and (b) develop models which can accurately predict the levels of microorganisms in urban stormwater to aid in health risk assessments. A crucial part of understanding the behaviour of pollutants in urban stormwater is to determine whether the pollutant experiences higher levels in certain portions of the event (e.g. does the pollutant experience a first flush?). The aim of this paper is twofold: (a) determine if the first flush phenomenon exists for a commonly used microbial indicator, Escherichia coli, and (b) determine whether the presence of a first flush is dependent on antecedent climatic and/or hydrologic characteristics. E. coli data collected from the wet weather flows of four urban catchments in Melbourne was used in the paper. Cumulative mass versus volume curves were used in conjunction with standard statistical inferences to determine that the first flush phenomenon was not consistently present, and that the presence and magnitude of a first flush varied considerably between each site. Regression analyses were used to determine that this variation was probably not caused by the same governing processes for all four sites, with different explanatory variables significantly explaining the first flush at each site.
Marshall-McKenna, R; Morrison, A; Stirling, L; Hutchison, C; Rice, A M; Hewitt, C; Paul, L; Rodger, M; Macpherson, I R; McCartney, E
2016-04-01
Quality of life in women receiving adjuvant endocrine therapy for breast cancer (BC) may be impaired by hot flushes and night sweats. The cool pad pillow topper (CPPT) is a commercial product, promoted to improve quality of sleep disrupted by hot flushes. This study aimed to identify if the CPPT reduces severity of sleep disturbance by minimising effects of hot flushes. This randomised phase II trial, recruited women with BC, on adjuvant endocrine therapy, experiencing hot flushes and insomnia. Participants were randomised (stratified by baseline sleep efficiency score (SES) and menopausal status) to the intervention arm (CPPT + standard care) or control arm (standard care). Participants completed Hospital Anxiety and Depression Scale and Functional Assessment of Cancer Therapy-Breast (FACT-B) questionnaires and fortnightly sleep/hot flush diaries (where responses were averaged over 2-week periods). The primary endpoint was change in average SES from -2 to 0 weeks to 2 to 4 weeks. Seventy-four pre- (68.9 %) and post-menopausal (31.1 %) women were recruited. Median age was 49.5 years. Endocrine therapies included tamoxifen (93.2 %). Median SES at weeks 2 to 4 improved in both arms but the increase on the intervention arm was almost twice that on the control arm (p = 0.024). There were significantly greater reductions in hot flushes and HADS depression in the intervention arm (p = 0.09 and p = 0.036, respectively). There were no significant differences in FACT-B or HADS anxiety. This study supports the use of the CPPT as an aid to reduce sleep disturbance and the frequency/severity of hot flushes.
Ueda, Yu; Odunayo, Adesola; Mann, F A
2013-01-01
To determine whether heparinized saline would be more effective in maintaining the patency of peripheral IV catheters in dogs compared to 0.9% sodium chloride. Prospective blinded randomized study. University Veterinary Teaching Hospital. Thirty healthy purpose bred dogs, intended for use in the junior surgery laboratory, were utilized. The dogs were randomized into 1 of 3 groups, 2 treatment groups and a control group. An 18-Ga cephalic catheter was placed in the cephalic vein of each dog. Each dog in the treatment group had their catheter flushed with either 10 IU/mL heparinized saline or 0.9% sodium chloride every 6 hours for 42 hours. The dogs in the control group did not have their catheters flushed until the end of the study period. Immediately prior to flushing catheters, each catheter was evaluated for patency by aspiration of blood and the catheter site was evaluated for phlebitis. All dogs in the heparinized saline and 0.9% sodium chloride group had catheters that flushed easily at each evaluation point. More dogs in the saline group had catheters from which blood could not be aspirated, but there was no significant difference between these groups. All dogs in the control group had catheters that flushed easily at the end of the assigned 6 hour interval except in 1 dog. Phlebitis was not detected in any dog. Flushes of 0.9% sodium chloride were found to be as effective as 10 IU/mL heparinized saline flushes in maintaining patency of 18-Ga peripheral venous catheters in dogs for up to 42 hours. For peripheral catheters placed with the intention of performing serial blood draws, heparinized flushes may be warranted. © Veterinary Emergency and Critical Care Society 2013.
Flushing of a coastal lagoon in the Red Sea
NASA Astrophysics Data System (ADS)
Sultan, S. A. R.; Ahmad, F.
1990-09-01
Shu'aiba Lagoon (Lat. 20°45'N; Long. 39°28'E) is located on the eastern coast of the Red Sea. It is relatively shallow with an area of approximately 11·7 km 2. The inlet to the lagoon is narrow with a cross-sectional area of about 245 m 2. This lagoon is a future site to develop mariculture. With this objective in view the flushing time scale of the lagoon was calculated, as flushing is an important abiotic factor in lagoon ecology. The average flushing time for the months February to June and September to November is about 20 days. Oceanic inputs play an important part in the process of fertilization of the lagoons. The marine environment in arid zone lagoons is under natural stress due to high temperatures and salinities. However, the flushing time scale of 20 days may not exert intolerable stress on the ecology of the Shu'aiba Lagoon.
Ramadan, Bimastyaji Surya; Sari, Gina Lova; Rosmalina, Raden Tina; Effendi, Agus Jatnika; Hadrah
2018-07-15
Combination of electrokinetic soil flushing and bioremediation (EKSF-Bio) technology has attracted many researchers attention in the last few decades. Electrokinetic is used to increase biodegradation rate of microorganisms in soil pores. Therefore, it is necessary to use solubilizing agents such as surfactants that can improve biodegradation process. This paper describes the basic understanding and recent development associated with electrokinetic soil flushing, bioremediation, and its combination as innovative hybrid solution for treating hydrocarbon contaminated soil. Surfactant has been widely used in many studies and practical applications in remediation of hydrocarbon contaminant, but specific review about those combination technology cannot be found. Surfactants and other flushing/solubilizing agents have significant effects to increase hydrocarbon remediation efficiency. Thus, this paper is expected to provide clear information about fundamental interaction between electrokinetic, flushing agents and bioremediation, principal factors, and an inspiration for ongoing and future research benefit. Copyright © 2018 Elsevier Ltd. All rights reserved.
Follicular flushing during oocyte retrieval: a systematic review and meta-analysis.
Roque, Matheus; Sampaio, Marcos; Geber, Selmo
2012-11-01
The purpose of this systematic review and meta-analysis was to examine the literature and identify randomized controlled trials (RCTs), in order to answer if performing follicular flushing during the oocyte retrieval may improve the assisted reproductive technologies (ART) outcomes. An exhaustive electronic search was performed using MEDLINE and EMBASE databases. Only RCTs comparing follicular flushing to aspiration only during ART, were included. We included 5 trials, with a total of 482 patients randomized, with median ages ranging from 30.5 to 37.1. The data analyses did not show significant differences regarding live birth rate, clinical pregnancies rates, and the number of oocytes retrieved. The duration of oocyte retrieval was significantly increased in the follicular flushing group. The results from this systematic review and meta-analysis suggest that there is no advantage to use of routine follicular flushing during OR in an unselected group of patients.
NASA Astrophysics Data System (ADS)
Nashida, Norihiro; Suzuki, Hiroaki
A microfluidic system with injecting and flushing functions was developed. In the system, hydrophilic flow channels have a dry-film photoresist layer which facilitates the introduction of solutions from four injection ports. The injection and flushing of solutions are controlled by valves operated by electrowetting. The valves consist of gold working electrodes in the flow channels or a through-hole in the glass substrate. Solutions can be sequentially introduced through the injection ports into a reaction chamber and flushed through a valve in the through-hole. Necessary immunoassay steps can be conducted on the chip, and a target antibody can be detected electrochemically.
Wilkin, J K
1983-03-01
The effects of clonidine hydrochloride, an agent effective in suppressing other types of flushing reactions, were investigated in patients with erythematotelangiectatic rosacea. Clonidine hydrochloride, 0.05 mg, was given orally twice daily for two weeks. Mean arterial BP was not altered during clonidine treatment. Flushing reactions provoked with water at 60 degrees C, red wine, and chocolate were not suppressed during clonidine treatment. Clonidine did lead to malar hypothermia. It may be that any treatment benefit obtained from the reduction in vascular reactivity by clonidine in rosacea is offset by the malar hypothermia.
Fu, Yongshuo S. H.; Campioli, Matteo; Vitasse, Yann; De Boeck, Hans J.; Van den Berge, Joke; AbdElgawad, Hamada; Asard, Han; Piao, Shilong; Deckmyn, Gaby; Janssens, Ivan A.
2014-01-01
Recent temperature increases have elicited strong phenological shifts in temperate tree species, with subsequent effects on photosynthesis. Here, we assess the impact of advanced leaf flushing in a winter warming experiment on the current year’s senescence and next year’s leaf flushing dates in two common tree species: Quercus robur L. and Fagus sylvatica L. Results suggest that earlier leaf flushing translated into earlier senescence, thereby partially offsetting the lengthening of the growing season. Moreover, saplings that were warmed in winter–spring 2009–2010 still exhibited earlier leaf flushing in 2011, even though the saplings had been exposed to similar ambient conditions for almost 1 y. Interestingly, for both species similar trends were found in mature trees using a long-term series of phenological records gathered from various locations in Europe. We hypothesize that this long-term legacy effect is related to an advancement of the endormancy phase (chilling phase) in response to the earlier autumnal senescence. Given the importance of phenology in plant and ecosystem functioning, and the prediction of more frequent extremely warm winters, our observations and postulated underlying mechanisms should be tested in other species. PMID:24799708
Water Reclamation Using a Ceramic Nanofiltration Membrane and Surface Flushing with Ozonated Water
Hoang, Anh T.; Okuda, Tetsuji; Takeuchi, Haruka; Tanaka, Hiroaki; Nghiem, Long D.
2018-01-01
A new membrane fouling control technique using ozonated water flushing was evaluated for direct nanofiltration (NF) of secondary wastewater effluent using a ceramic NF membrane. Experiments were conducted at a permeate flux of 44 L/m2h to evaluate the ozonated water flushing technique for fouling mitigation. Surface flushing with clean water did not effectively remove foulants from the NF membrane. In contrast, surface flushing with ozonated water (4 mg/L dissolved ozone) could effectively remove most foulants to restore the membrane permeability. This surface flushing technique using ozonated water was able to limit the progression of fouling to 35% in transmembrane pressure increase over five filtration cycles. Results from this study also heighten the need for further development of ceramic NF membrane to ensure adequate removal of pharmaceuticals and personal care products (PPCPs) for water recycling applications. The ceramic NF membrane used in this study showed approximately 40% TOC rejection, and the rejection of PPCPs was generally low and highly variable. It is expected that the fouling mitigation technique developed here is even more important for ceramic NF membranes with smaller pore size and thus better PPCP rejection. PMID:29671797
Cigarette smoking, androgen levels, and hot flushes in midlife women.
Cochran, Chrissy J; Gallicchio, Lisa; Miller, Susan R; Zacur, Howard; Flaws, Jodi A
2008-11-01
To test the hypothesis that cigarette smoking is associated with hot flushes through a mechanism involving androgen levels, progesterone levels, sex hormone-binding globulin levels, or the ratio of androgens to estrogens. Women with and without hot flushes were recruited from Baltimore, Maryland, and the surrounding counties. Women were between 45 and 54 years of age, with at least three menstrual periods in the previous 12 months, and were not postmenopausal. Study participants completed a questionnaire and gave a blood sample for hormone measurements. Current smokers had significantly higher androstenedione levels and a higher androgen-to-estrogen ratio than never smokers. Current smokers had significantly lower progesterone levels compared with never smokers. Former and current cigarette smokers had increased odds of experiencing hot flushes compared with never smokers (former: odds ratio [OR] 1.41, 95% confidence interval [CI] 0.99-2.01; current: OR 2.43, 95% CI 1.28-4.62). This association, however, was not attenuated by the addition of hormones to the smoking and hot-flush model. Cigarette smoking is associated with hot flushes through a mechanism that may not involve alterations in hormone levels or their ratios. II.
Fu, Yongshuo S H; Campioli, Matteo; Vitasse, Yann; De Boeck, Hans J; Van den Berge, Joke; AbdElgawad, Hamada; Asard, Han; Piao, Shilong; Deckmyn, Gaby; Janssens, Ivan A
2014-05-20
Recent temperature increases have elicited strong phenological shifts in temperate tree species, with subsequent effects on photosynthesis. Here, we assess the impact of advanced leaf flushing in a winter warming experiment on the current year's senescence and next year's leaf flushing dates in two common tree species: Quercus robur L. and Fagus sylvatica L. Results suggest that earlier leaf flushing translated into earlier senescence, thereby partially offsetting the lengthening of the growing season. Moreover, saplings that were warmed in winter-spring 2009-2010 still exhibited earlier leaf flushing in 2011, even though the saplings had been exposed to similar ambient conditions for almost 1 y. Interestingly, for both species similar trends were found in mature trees using a long-term series of phenological records gathered from various locations in Europe. We hypothesize that this long-term legacy effect is related to an advancement of the endormancy phase (chilling phase) in response to the earlier autumnal senescence. Given the importance of phenology in plant and ecosystem functioning, and the prediction of more frequent extremely warm winters, our observations and postulated underlying mechanisms should be tested in other species.
Ambrus, R; Svendsen, L B; Secher, N H; Goetze, J P; Rünitz, K; Achiam, M P
2017-09-01
During abdominal surgery, traction of the mesenterium provokes mesenteric traction syndrome, including hypotension, tachycardia, and flushing, along with an increase in plasma prostacyclin (PGI 2 ). We evaluated whether postoperative complications are related to mesenteric traction syndrome during esophagectomy. Flushing, hemodynamic variables, and plasma 6-keto-PGF 1α were recorded during the abdominal part of open ( n = 25) and robotically assisted ( n = 25) esophagectomy. Postoperative complications were also registered, according to the Clavien-Dindo classification. Flushing appeared in 17 (open) and 5 (robotically assisted) surgical cases ( p = 0.001). Mean arterial pressure was stable during both types of surgeries, but infusion of vasopressors during the first hour of open surgery was related to development of widespread (Grade II) flushing ( p = 0.036). For patients who developed flushing, heart rate and plasma 6-keto-PGF 1α also increased ( p = 0.001 and p < 0.001, respectively). Furthermore, severe postoperative complications were related to Grade II flushing ( p = 0.037). Mesenteric traction syndrome manifests more frequently during open than robotically assisted esophagectomy, and postoperative complications appear to be associated with severe mesenteric traction syndrome.
Water Reclamation Using a Ceramic Nanofiltration Membrane and Surface Flushing with Ozonated Water.
Fujioka, Takahiro; Hoang, Anh T; Okuda, Tetsuji; Takeuchi, Haruka; Tanaka, Hiroaki; Nghiem, Long D
2018-04-19
A new membrane fouling control technique using ozonated water flushing was evaluated for direct nanofiltration (NF) of secondary wastewater effluent using a ceramic NF membrane. Experiments were conducted at a permeate flux of 44 L/m²h to evaluate the ozonated water flushing technique for fouling mitigation. Surface flushing with clean water did not effectively remove foulants from the NF membrane. In contrast, surface flushing with ozonated water (4 mg/L dissolved ozone) could effectively remove most foulants to restore the membrane permeability. This surface flushing technique using ozonated water was able to limit the progression of fouling to 35% in transmembrane pressure increase over five filtration cycles. Results from this study also heighten the need for further development of ceramic NF membrane to ensure adequate removal of pharmaceuticals and personal care products (PPCPs) for water recycling applications. The ceramic NF membrane used in this study showed approximately 40% TOC rejection, and the rejection of PPCPs was generally low and highly variable. It is expected that the fouling mitigation technique developed here is even more important for ceramic NF membranes with smaller pore size and thus better PPCP rejection.
Munsch-Alatossava, Patricia; Alatossava, Tapani
2014-01-01
Gram-negative Pseudomonas and Gram-positive Bacillus are the most common spoilage bacteria in raw and pasteurized milk, respectively. In previous studies, nitrogen (N2) gas flushing treatments of raw and pasteurized milk at cold chain-temperatures inhibited bacterial spoilage and highlighted different susceptibilities to the N2 treatment with the exclusion of certain bacterial types. Here, we investigated the effects of pure N2 gas flushing on representative strains of these genera grown in mono- or co-cultures at 15 and 25°C. Bacillus weihenstephanensis, a frequent inhabitant of fluid dairy products, is represented by the genome-sequenced KBAB4 strain. Among Pseudomonas, P. tolaasii LMG 2342(T) and strain C1, a raw milk psychrotroph, were selected. The N2 gas flushing treatment revealed: (1) temperature-dependent responses; (2) inhibition of the growth of both pseudomonads; (3) emergence of small colony variants (SCVs) for B. weihenstephanensis strain KBAB4 at 15°C induced by the N2 treatment or when grown in co-culture with Pseudomonas strains; (4) N2 gas flushing modulates (suppressed or stimulated) bacterial antagonistic reactions in co-cultures; (5) most importantly, scanning electron microscopy (SEM) and transmission electron microscopy (TEM) analyses revealed that at 25°C the majority of the KBAB4 cells were killed by pure N2 gas flushing. This observation constitutes the first evidence that N2 gas flushing has bactericidal effects.
Hinds, Angelique C; Baskin, Laurence S
2004-10-01
The Malone antegrade continence enema procedure has changed the lives of many school-aged children who would otherwise be in diapers. Unfortunately, our current procedures to flush the Malone antegrade continence enema are difficult to accomplish independently and require an extensive time commitment. In this study we confirm that a new device, the ACE Malone automatic instillation device (ACE-MAID) is safe and effective, will decrease the time it takes to perform the flush and will increase independence. Nine patients were prospectively enrolled for a 1-year study. Patient age ranged from 4 to 16 years, and diagnoses included spina bifida (3 cases), imperforate anus (4) and infantile meningitis (1). The study consisted of initial and followup questionnaires, an "ACE-O-Gram," quality assurance testing of the ACE-MAID and an objective observation of current flushing technique. The average objective start to finish flush time decreased from 45 minutes initially to 31 minutes using the ACE-MAID. Children who initially had more than 1 accident per month had a decrease in the number of stool accidents. When asked to compare the ACE-MAID device to the previous form of flushing 100% of patients stated that it was better. When asked if they would use the pump when the study was over 100% reported yes. The new ACE-MAID proved safe and effective, decreased flush times, may decrease stool accidents and facilitates independence for children treated with a MACE procedure.
Rondeau, M; Guay, P; Goff, A K; Cooke, G M
1996-01-01
The aim of this study was to compare the development and metabolic activity of cultured murine and bovine embryos in 2 standard media (HAM F-10 and RPMI) in the presence or absence of bovine uterine flushings. Murine morulae (n = 653) and day 7 bovine embryos (n = 273) were cultured for 18 h or 36 h in either HAM F-10 or RPMI in the presence or absence of bovine uterine flushings. After culture, the development, quality, and metabolic activity (glucose utilization or methionine uptake and incorporation) of embryos was assessed. It was found that HAM F-10 (without uterine flushings) was a more suitable medium than RPMI for optimal development and metabolism of murine and bovine embryos. Poor quality and development, as well as decreased metabolism, were evident after culture of murine embryos in RPMI; in contrast, this medium had no adverse effects on bovine embryos in culture. Supplementation of HAM F-10 with bovine uterine flushings improved the growth of murine embryos and the protein synthesis (as measured by an increased methionine incorporation) for both murine and bovine embryos. However, supplementation with bovine uterine flushings could not overcome deficiencies of an inappropriate medium (RPMI) for murine embryos. Supplementation of a well-defined culture medium with uterine flushings increased metabolism of embryos in culture, and thus might help to increase pregnancy rates after transfer of such embryos to recipient cows. PMID:8825988
Rodney E. Will; Greg Barron-Gafford; Robert O. Teskey; Barry D. Shiver
2004-01-01
Mid-summer foliar nitrogen concentrations (N) were measured at three canopy positions (upper, middle, lower), two foliage ages per canopy position (current-year and 1-year-old), and two flushes per age class (first flush and second flush) in 4-year-old loblolly (Pinus taeda L.) and slash pine (Pinus elliottii Engelm.) stands...
K.D. Jermstad; D.L. Bassoni; K.S. Jech; N.C. Wheeler; D.B. Neale
2001-01-01
Abstract Thirty three unique quantitative trait loci (QTLs) affecting the timing of spring bud flush have been identified in an intraspecific mapping population of coastal Douglas-fir [Pseudotsuga menziesii (Mirb.) Franco var. menziesii]. Both terminal and lateral bud flush were measured over a 4-year period on clonal replicates at two test sites, allowing for the...
Richard E. Dickson; Patricia T. Tomlinson; J. G. Isebrands
2000-01-01
The episodic or flushing growth habit of northern red oak (Quercus rubra L.,) has a significant influence on carbon fixation, carbon transport from source leaves, and carbon allocation within the plant; however, the impact of episodic growth on carbon parciprioning among chemical fractions is unknown. Median-flush leaves of the first and second flush...
Huynh, Lynn; Totev, Todor; Vekeman, Francis; Neary, Maureen P; Duh, Mei S; Benson, Al B
2017-09-01
To calculate the cost reduction associated with diarrhea/flushing symptom resolution/improvement following treatment with above-standard dose octreotide-LAR from the commercial payor's perspective. Diarrhea and flushing are two major carcinoid syndrome symptoms of neuroendocrine tumor (NET). Previously, a study of NET patients from three US tertiary oncology centers (NET 3-Center Study) demonstrated that dose escalation of octreotide LAR to above-standard dose resolved/improved diarrhea/flushing in 79% of the patients within 1 year. Time course of diarrhea/flushing symptom data were collected from the NET 3-Center Study. Daily healthcare costs were calculated from a commercial claims database analysis. For the patient cohort experiencing any diarrhea/flushing symptom resolution/improvement, their observation period was divided into days of symptom resolution/improvement or no improvement, which were then multiplied by the respective daily healthcare cost and summed over 1 year to yield the blended mean annual cost per patient. For patients who experienced no diarrhea/flushing symptom improvement, mean annual daily healthcare cost of diarrhea/flushing over a 1-year period was calculated. The economic model found that 108 NET patients who experienced diarrhea/flushing symptom resolution/improvement within 1 year had statistically significantly lower mean annual healthcare cost/patient than patients with no symptom improvement, by $14,766 (p = .03). For the sub-set of 85 patients experiencing resolution/improvement of diarrhea, their cost reduction was more pronounced, at $18,740 (p = .01), statistically significantly lower than those with no improvement; outpatient costs accounted for 56% of the cost reduction (p = .02); inpatient costs, emergency department costs, and pharmacy costs accounted for the remaining 44%. The economic model relied on two different sources of data, with some heterogeneity in the prior treatment and disease status of patients. Symptom resolution/improvement of diarrhea/flushing after treatment with an above-standard dose of octreotide-LAR in NET was associated with a statistically significant healthcare cost decrease compared to a scenario of no symptom improvement.
Call, Anson C; St Clair, Samuel B
2017-09-01
In the spring of 2015, a severe outbreak of the necrotrophic pathogen Drepanopeziza (also known as Marssonina) spread across large portions of aspen (Populus tremuloides Michx.) forests in the western United States. Among adjacent stands, some were diseased and others were not. Drepanopeziza infection in diseased aspen stands stimulated compensatory growth of second-flush leaves at the top of the canopy. These patterns of infection provided an opportunity to characterize associations of pathogen infection and leaf functional traits. Eight pairs of adjacent healthy and diseased aspen stands were identified across a forest landscape in northern Utah. Average leaf surface area, specific leaf area (SLA), photosynthesis, starch concentration and defense chemistry expression (phenolic glycosides and condensed tannins) were measured on original, first-flush leaves in the lower portion of the tree canopy of healthy and diseased stands and compensatory, second-flush leaves produced in the canopy top of diseased stands. Only first-flush leaves of diseased stands showed high levels of Drepanopeziza infection. Leaf area of second-flush leaves of diseased stands was threefold larger than all other leaf types in healthy or diseased stands. Lower canopy leaves of healthy stands had the highest SLA. Photosynthesis was lowest in infected first-flush leaves, highest in second-flush leaves of diseased stands and intermediate in leaves of healthy stands. Foliar starch concentrations were lower in leaves of diseased stands than leaves from healthy stands. Condensed tannins were greater in second-flush leaves than first-flush leaves in both healthy and diseased stands. Phenolic glycoside concentrations were lowest in infected leaves of diseased stands. Diseased stands leafed out a week earlier in the spring than healthy stands, which may have exposed their emerging leaves to rainy conditions that promote Drepanopeziza infection. Compensatory leaf regrowth of diseased stands appears to offset some of the functional loss (i.e., photosynthetic capacity) of infected leaves. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Kim, Kun-Hyung; Kang, Kyung-Won; Jung, Hee-Jung; Park, Ji-Eun; Jung, So-Young; Choi, Jun-Yong; Choi, Sun-Mi
2008-01-01
Background Hot flushes are the most frequent climacteric symptom and a major cause of suffering among menopausal women. The condition negatively influences many aspects of women's lives. To date, conventional hormone replacement therapy (HRT) is considered the most effective treatment for hot flushes. However, HRT is associated with a host of negative side effects. Complementary and alternative medical (CAM) approaches have been employed to relieve symptoms and to avoid these side effects. Acupuncture is one of the most strongly preferred CAM treatments for many diseases, causing few serious adverse effects, and is frequently used in Korea. We aim to evaluate the effectiveness of Traditional Korean Acupuncture (TKA) in conjunction with usual care, compared to usual care alone, on hot flushes in perimenopausal and postmenopausal women in Korea. Methods This study consists of a multi-center randomized controlled trial with 2 parallel arms. Participants included in the study will meet the following criteria: 1) a documented daily average hot flush score ≥ 10 for one week prior to the screening visit 2) not taking HRT and other pharmaceutical therapies which might affect hot flushes or other vasomotor symptoms. While maintaining usual care, the treatment group will receive acupuncture 3 times a week, for a total of 12 sessions over 4 weeks. The control group will receive usual care alone during the same period. Post-treatment follow-up will be performed one month after completing 12 sessions of acupuncture. Discussion This trial will provide evidence for the effectiveness of acupuncture as a treatment for hot flushes. The primary endpoint in both groups is a change in hot flush score from baseline to week 4 and/or week 8. As the secondary endpoint, we will employ the Menopause Rating Scale (MRS), a health-related quality of life questionnaire. Further analysis will examine the frequency, severity and difference in symptoms for daytime vs. nighttime hot flushes, sub-domain analysis of MRS, and participants' expectations of acupuncture treatment. Trial registration Current Controlled Trials ISRCTN49335612 PMID:19055763
The application of improved flow diverter for first flush management.
Mrowiec, M
2010-01-01
The paper presents the investigations on first flush phenomenon based on the total suspended solids (TSS) concentration measurement during selected rainfalls at central part of Czestochowa (Poland) and also the hydrodynamic model of the catchment. The model allows to present the conception of first flush management using an improved flow diverter Septurn. Flow diverters used in the separate sewer systems create a hybrid system called "semi-separate" sewage system, which allows to treat the first flush volume in the waste water treatment plant (WWTP). Proposed construction of the flow diverter makes possible to capture significant part of the pollutant load (TSS) and simultaneously to reduce volume discharges to WWTPs during wet weather.
Leachate flush strategies for managing volatile fatty acids accumulation in leach-bed reactors.
Riggio, S; Torrijos, M; Vives, G; Esposito, G; van Hullebusch, E D; Steyer, J P; Escudié, R
2017-05-01
In anaerobic leach-bed reactors (LBRs) co-digesting an easily- and a slowly-degradable substrate, the importance of the leachate flush both on extracting volatile fatty acids (VFAs) at the beginning of newly-started batches and on their consumption in mature reactors was tested. Regarding VFA extraction three leachate flush-rate conditions were studied: 0.5, 1 and 2Lkg -1 TSd -1 . Results showed that increasing the leachate flush-rate during the acidification phase is essential to increase degradation kinetics. After this initial phase, leachate injection is less important and the flush-rate could be reduced. The injection in mature reactors of leachate with an acetic acid concentration of 5 or 10gL -1 showed that for an optimized VFA consumption in LBRs, VFAs should be provided straight after the methane production peak in order to profit from a higher methanogenic activity, and every 6-7h to maintain a high biogas production rate. Copyright © 2017 Elsevier Ltd. All rights reserved.
Rance, Naomi E.; Dacks, Penny A.; Mittelman-Smith, Melinda A.; Romanovsky, Andrej A.; Krajewski-Hall, Sally J.
2013-01-01
Despite affecting millions of individuals, the etiology of hot flushes remains unknown. Here we review the physiology of hot flushes, CNS pathways regulating heat-dissipation effectors, and effects of estrogen on thermoregulation in animal models. Based on the marked changes in hypothalamic kisspeptin, neurokinin B and dynorphin (KNDy) neurons in postmenopausal women, we hypothesize that KNDy neurons play a role in the mechanism of flushes. In the rat, KNDy neurons project to preoptic thermoregulatory areas that express the neurokinin 3 receptor (NK3R), the primary receptor for NKB. Furthermore, activation of NK3R in the median preoptic nucleus, part of the heat-defense pathway, reduces body temperature. Finally, ablation of KNDy neurons reduces cutaneous vasodilatation and partially blocks the effects of estrogen on thermoregulation. These data suggest that arcuate KNDy neurons relay estrogen signals to preoptic structures regulating heat-dissipation effectors, supporting the hypothesis that KNDy neurons participate in the generation of flushes. PMID:23872331
Simulated formation and flow of microemulsions during surfactant flushing of contaminated soil.
Ouyan, Ying; Cho, Jong Soo; Mansell, Robert S
2002-01-01
Contamination of groundwater resources by non-aqueous phase liquids (NAPLs) has become an issue of increasing environmental concern. This study investigated the formation and flow of microemulsions during surfactant flushing of NAPL-contaminated soil using the finite difference model UTCHEM, which was verified with our laboratory experimental data. Simulation results showed that surfactant flushing of NAPLs (i.e., trichloroethylene and tetrachloroethylene) from the contaminated soils was an emulsion-driven process. Formation of NAPL-in-water microemulsions facilitated the removal of NAPLs from contaminated soils. Changes in soil saturation pressure were used to monitor the mobilization and entrapment of NAPLs during surface flushing process. In general, more NAPLs were clogged in soil pores when the soil saturation pressure increased. Effects of aquifer salinity on the formation and flow of NAPL-in-water microemulsions were significant. This study suggests that the formation and flow of NAPL-in-water microemulsions through aquifer systems are complex physical-chemical phenomena that are critical to effective surfactant flushing of contaminated soils.
2006-08-31
volumetric depletion efficiency ( VDE ) considers how much DNAPL is depleted from the system, relative to the total volume of solution flushed through the...aqueous phase contaminant. VDE is important to consider, as conditions that result in the fastest mass transfer, highest enhancement, or best MTE, may...volumes of flushing fluid, maximizing DNAPL depletion while minimizing flushing volume requirements may be desirable from a remediation standpoint. VDE
Relation of body mass and sex steroid hormone levels to hot flushes in a sample of mid-life women.
Schilling, C; Gallicchio, L; Miller, S R; Langenberg, P; Zacur, H; Flaws, J A
2007-02-01
Previous studies indicate that obesity is associated with a higher risk of experiencing hot flushes in mid-life women. The reasons for this association are unknown, although altered hormone levels have been associated with both hot flushes and obesity. Thus, this current study tested the hypothesis that obesity is associated with hot flushes in mid-life women through a mechanism involving levels of total and free androgen, free estrogen, progesterone, and sex hormone binding globulin (SHBG). Women aged 45-54 years were recruited from Baltimore and its surrounding counties. Each participant (n=628) was weighed, measured, completed a questionnaire, and provided a blood sample that was used to measure estradiol, estrone, testosterone, androstenedione, dehydroepiandrosterone sulfate, progesterone, and SHBG. Obese mid-life women (body mass index (BMI)>or=30.0 kg/m2) had significantly higher testosterone, and lower estradiol, estrone, progesterone, and SHBG levels than normal-weight mid-life women (BMI
Bach, P M; McCarthy, D T; Deletic, A
2010-01-01
The management of stormwater pollution has placed particular emphasis on the first flush phenomenon. However, definition and current methods of analyses of the phenomena contain serious limitations, the most important being their inability to capture a possible impact of the event size (total event volume) on the first flush. This paper presents the development of a novel approach in defining and assessing the first flush that should overcome these problems. The phenomenon is present in a catchment if the decrease in pollution concentration with the absolute cumulative volume of runoff from the catchment is statistically significant. Using data from seven diverse catchments around Melbourne, Australia, changes in pollutant concentrations for Total Suspended Solids (TSS) and Total Nitrogen (TN) were calculated over the absolute cumulative runoff and aggregated from a collection of different storm events. Due to the discrete nature of the water quality data, each concentration was calculated as a flow-weighted average at 2 mm runoff volume increments. The aggregated concentrations recorded in each increment (termed as a 'slice' of runoff) were statistically compared to each other across the absolute cumulative runoff volume. A first flush is then defined as the volume at which concentrations reach the 'background concentration' (i.e. the statistically significant minimum). Initial results clearly highlight first flush and background concentrations in all but one catchment supporting the validity of this new approach. Future work will need to address factors, which will help assess the first flush's magnitude and volume. Sensitivity testing and correlation with catchment characteristics should also be undertaken.
Wilson, Louise F; Pandeya, Nirmala; Byles, Julie; Mishra, Gita D
2016-09-01
There is limited research on hot flushes and night sweats in women with a hysterectomy with ovarian conservation. We aimed to describe the patterns of these symptoms in a cohort of Australian women and to investigate the relationship between distinct symptom patterns and hysterectomy status. Repeated-measures latent class analysis (LCA) was used to identify hot flushes and night sweats symptom patterns across seven surveys (over 17 years) in the mid-cohort of the Australian Longitudinal Study on Women's Health. Multinomial logistic regression was used to assess the associations of the symptom patterns in women with a hysterectomy with ovarian conservation (n=1129) versus women without a hysterectomy (n=4977). A higher proportion of women with a hysterectomy than of those without experienced a constant pattern of hot flushes (15% versus 30%) and night sweats (9% versus 19%). Women with a hysterectomy had higher odds of constant hot flushes versus minimal hot flushes (OR=1.97, 95% CI: 1.64, 2.35) and constant versus minimal night sweats (OR=2.09, 95% CI: 1.70, 2.55). Smoking, a 'lower level of education to non-professional occupation' pathway and body mass index (BMI) patterns of 'always obese' and 'increasingly obese' were also associated with a higher risk of constant symptoms. Women who have a hysterectomy (with ovarian conservation) have a higher risk of hot flushes and night sweats that persist over an extended period. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Adams, A.; Gore, J.; Musser, F.; Cook, D.; Catchot, A.; Walker, T.; Awuni, G. A.
2015-01-01
Two experiments were conducted at the Delta Research and Extension Center in Stoneville, MS, during 2011 and 2012 to determine the impact of water management practices on the efficacy of insecticidal seed treatments targeting rice water weevil, Lissorhoptrus oryzophilus Kuschel. Larval densities and yield were compared for plots treated with labeled rates of thiamethoxam, chlorantraniliprole, and clothianidin and an untreated control. In the first experiment, plots were subjected to flood initiated at 6 and 8 wk after planting. Seed treatments significantly reduced larval densities with the 8-wk flood timing, but not the 6-wk flood timing. Overall, the treated plots yielded higher than the control plots. In the second experiment, the impact of multiple flushes on the efficacy of insecticidal seed treatments was evaluated. Plots were subjected to zero, one, or two flushes with water. All seed treatments reduced larval densities compared with the untreated control. Significantly fewer larvae were observed in plots that received one or two flushes compared with plots that did not receive a flush. All seed treatments resulted in higher yields compared to the untreated control in the zero and one flush treatments. When two flushes were applied, yield from the thiamethoxam and clothianidin treated plots was not significantly different from those of the control plots, while the chlorantraniliprole treated plots yielded significantly higher than the control. These data suggest that time from planting to flood did not impact the efficacy of seed treatments, but multiple flushes reduced the efficacy of thiamethoxam and clothianidin. PMID:26470232
Modulation of magmatic processes by CO2 flushing
NASA Astrophysics Data System (ADS)
Caricchi, Luca; Sheldrake, Tom E.; Blundy, Jon
2018-06-01
Magmatic systems are the engines driving volcanic eruptions and the source of fluids responsible for the formation of porphyry-type ore deposits. Sudden variations of pressure, temperature and volume in magmatic systems can produce unrest, which may culminate in a volcanic eruption and/or the abrupt release of ore-forming fluids. Such variations of the conditions within magmatic systems are commonly ascribed to the injection of new magma from depth. However, as magmas fractionating at depth or rising to the upper crust release CO2-rich fluids, the interaction between carbonic fluids and H2O-rich magmas stored in the upper crust (CO2 flushing), must also be a common process affecting the evolution of subvolcanic magma reservoirs. Here, we investigate the effect of gas injection on the stability and chemical evolution of magmatic systems. We calculate the chemical and physical evolution of magmas subjected to CO2-flushing using rhyolite-MELTS. We compare the calculations with a set of melt inclusion data for Mt. St. Helens, Merapi, Etna, and Stromboli volcanoes. We provide an approach that can be used to distinguish between melt inclusions trapped during CO2 flushing, magma ascent and decompression, or those affected by post-entrapment H2O-loss. Our results show that CO2 flushing is a widespread process in both felsic and mafic magmatic systems. Depending upon initial magma crystallinity and duration of CO2 input, flushing can either lead to volcanic eruption or fluid release. We suggest that CO2 flushing is a fundamental process modulating the behaviour and chemical evolution of crustal magmatic systems.
Pinkerton, JoAnn V; Bushmakin, Andrew G; Abraham, Lucy; Komm, Barry S; Bobula, Joel
2017-09-01
This post hoc analysis estimates time to transient and stable reductions in hot flush frequency in postmenopausal women using conjugated estrogens/bazedoxifene. In the 12-week Selective estrogens, Menopause, And Response to Therapy (SMART)-2 trial of conjugated estrogens/bazedoxifene 0.45 mg/20 mg and 0.625 mg/20 mg, women with at least seven moderate/severe hot flushes per day or 50 per week at screening recorded frequency of moderate/severe hot flushes in diaries. Nonparametric models and SAS Proc Lifetest were used to estimate median times to various degrees of transient reductions (first day with improvement) and stable reductions (first day with improvement maintained through study's end) in hot flush frequency. Treatment produced transient hot flush reductions of 40% to 100% and stable reductions of 30% to 100% significantly faster than placebo. Median time to a transient 50% reduction was 8 days for conjugated estrogens/bazedoxifene 0.45 mg/20 mg, 9.5 for 0.625 mg/20 mg, and 10 for placebo; median time to a stable 50% reduction was 9, 10, and 38 days. Median time to a transient 90% reduction was 32 and 22.5 days for 0.45 mg/20 mg and 0.625 mg/20 mg, and median time to a stable 90% reduction was 83 and 29 days, respectively; median times to transient/stable 90% reductions were not reached during the 12-week study in the placebo group. Although not all women using conjugated estrogens/bazedoxifene achieve permanent elimination of hot flushes, the frequency is likely to be substantially reduced during the first week to month. Women can expect approximately 50% reduction in hot flush frequency after about 8 to 10 days, and sustained improvement with continued treatment.
Development and growth of fruit bodies and crops of the button mushroom, Agaricus bisporus.
Straatsma, Gerben; Sonnenberg, Anton S M; van Griensven, Leo J L D
2013-10-01
We studied the appearance of fruit body primordia, the growth of individual fruit bodies and the development of the consecutive flushes of the crop. Relative growth, measured as cap expansion, was not constant. It started extremely rapidly, and slowed down to an exponential rate with diameter doubling of 1.7 d until fruit bodies showed maturation by veil breaking. Initially many outgrowing primordia were arrested, indicating nutritional competition. After reaching 10 mm diameter, no growth arrest occurred; all growing individuals, whether relatively large or small, showed an exponential increase of both cap diameter and biomass, until veil breaking. Biomass doubled in 0.8 d. Exponential growth indicates the absence of competition. Apparently there exist differential nutritional requirements for early growth and for later, continuing growth. Flushing was studied applying different picking sizes. An ordinary flushing pattern occurred at an immature picking size of 8 mm diameter (picking mushrooms once a day with a diameter above 8 mm). The smallest picking size yielded the highest number of mushrooms picked, confirming the competition and arrested growth of outgrowing primordia: competition seems less if outgrowing primordia are removed early. The flush duration (i.e. between the first and last picking moments) was not affected by picking size. At small picking size, the subsequent flushes were not fully separated in time but overlapped. Within 2 d after picking the first individuals of the first flush, primordia for the second flush started outgrowth. Our work supports the view that the acquisition of nutrients by the mycelium is demand rather than supply driven. For formation and early outgrowth of primordia, indications were found for an alternation of local and global control, at least in the casing layer. All these data combined, we postulate that flushing is the consequence of the depletion of some unknown specific nutrition required by outgrowing primordia. Copyright © 2013 The British Mycological Society. Published by Elsevier Ltd. All rights reserved.
Hypothesis of demodicidosis rosacea flushing etiopathogenesis.
Robledo, Mary Ann; Orduz, Mariana
2015-04-01
Most of the patients with erythematotelangiectatic rosacea are characterized by flushing, oedema and telangiectasia. The etiopathogenesis of the flushing in rosacea patients is unknown. Clinically the flushing in rosacea is similar to the "Asian flushing syndrome". Most Asians have an overactive alcohol dehydrogenase (ADH) that tends to break down alcohol into acetaldehyde faster. People with "Asians flushing syndrome" have a genetic disorder with the Aldehyde Dehydrogenase 2(∗)2 (ALDH2(∗)2) allele. This is the reason why they do not metabolize very well the acetaldehyde that comes from the alcohol, which means that acetaldehyde takes much longer to clear from their blood. ALDH2 enzyme is primarily responsible for oxidation of acetaldehyde derived from ethanol metabolism, as well as oxidation of various other endogenous and exogenous aldehydes. Acetaldehyde produces the vasodilatation in the "Asian flushing syndrome". The antibodies against the GroEl chaperonin protein, a 62-kDa heat shock protein were found in the Bacillus oleronius isolated from Demodex mites, in rosacea patients. The GroEl chaperonin protein is a protein that plays a key role in normal folding of ALDH2. If the GroEl chaperonin antibodies found in patients with rosacea, cross react with the human GroEl chaperonin protein, they will not fold normally the ALDH2, and then the enzyme will not metabolize the acetaldehyde. Many of the patients with rosacea have a concomitant infection with Helicobacter pylori in their stomach. The H.pylori produces high amounts of acetaldehyde, which comes from their metabolism of ethanol or carbohydrates. As a result, high amounts of acetaldehyde will circulate for longer time in the blood, until the liver CYP2E1(p450) enzyme system finally metabilizes the acetaldehyde, during that period of time the patients will experience a flushing as well as the people with the "Asian flushing syndrome" suffer when they drink ethanol. To prove the hypothesis it is necessary to find the cross reaction between the GroEl chaperonin antibodies against the B.oleronius and human GroEl chaperonin. Four groups of patients will be studied with or without the GroEl chaperonin antibodies, and H.Pylori. The production of acetaldehyde will be tested by the ethanol-derived microbial production method. If the hypothesis proves to be true, the treatment of Demodex mites and the H. pylori could improve the flushing in the rosacea patients and it will prevent the angiogenesis (telangiectasia), and the association of the gastric injury and carcinogenesis in those patients. Copyright © 2015 Elsevier Ltd. All rights reserved.
Flush Mounting Of Thin-Film Sensors
NASA Technical Reports Server (NTRS)
Moore, Thomas C., Sr.
1992-01-01
Technique developed for mounting thin-film sensors flush with surfaces like aerodynamic surfaces of aircraft, which often have compound curvatures. Sensor mounted in recess by use of vacuum pad and materials selected for specific application. Technique involves use of materials tailored to thermal properties of substrate in which sensor mounted. Together with customized materials, enables flush mounting of thin-film sensors in most situations in which recesses for sensors provided. Useful in both aircraft and automotive industries.
Jacobson, Terry A.
2010-01-01
Niacin is the most effective lipid-modifying agent for raising high-density lipoprotein cholesterol levels, but it also causes cutaneous vasodilation with flushing. To determine the frequency of flushing in clinical trials, as well as to delineate counseling and treatment approaches to prevent or manage flushing, a MEDLINE search was conducted of English-language literature from January 1, 1985, through April 7, 2009. This search used the title keywords niacin or nicotinic acid crossed with the Medical Subject Headings adverse effects and human. Niacin flushing is a receptor-mediated, mainly prostaglandin D2–driven phenomenon, the frequency, onset, and duration of which are largely determined by the distinct pharmacological and metabolic profiles of different niacin formulations. Subjective assessments include ratings of redness, warmth, itching, and tingling. In clinical trials, most (>60%) niacin users experienced mild or moderate flushing, which tended to decrease in frequency and severity with continued niacin treatment, even with advancing doses. Approximately 5% to 20% of patients discontinued treatment because of flushing. Flushing may be minimized by taking niacin with meals (or at bedtime with a low-fat snack), avoiding exacerbating factors (alcohol or hot beverages), and taking 325 mg of aspirin 30 minutes before niacin dosing. The current review advocates an initially slow niacin dose escalation from 0.5 to 1.0 g/d during 8 weeks and then from 1.0 to 2.0 g in a single titration step (if tolerated). Through effective counseling, treatment prophylaxis with aspirin, and careful dose escalation, adherence to niacin treatment can be improved significantly. Wider implementation of these measures should enable higher proportions of patients to reach sufficient niacin doses over time to prevent cardiovascular events. PMID:20360295
Bailey, Tom G; Cable, N Timothy; Aziz, Nabil; Dobson, Rebecca; Sprung, Victoria S; Low, David A; Jones, Helen
2016-07-01
Postmenopausal hot flushes occur due to a reduction in estrogen production causing thermoregulatory and vascular dysfunction. Exercise training enhances thermoregulatory control of sweating, skin and brain blood flow. We aimed to determine if improving thermoregulatory control and vascular function with exercise training alleviated hot flushes. Twenty-one symptomatic women completed a 7-day hot flush questionnaire and underwent brachial artery flow-mediated dilation and a cardiorespiratory fitness test. Sweat rate and skin blood flow temperature thresholds and sensitivities, and middle cerebral artery velocity (MCAv) were measured during passive heating. Women performed 16 weeks of supervised exercise training or control, and measurements were repeated. There was a greater improvement in cardiorespiratory fitness (4.45 mL/kg/min [95% CI: 1.87, 8.16]; P = 0.04) and reduced hot flush frequency (48 hot flushes/wk [39, 56]; P < 0.001) after exercise compared with control. Exercise reduced basal core temperature (0.14°C [0.01, 0.27]; P = 0.03) and increased basal MCAv (2.8 cm/s [1.0, 5.2]; P = 0.04) compared with control. Sweat rate and skin blood flow thresholds occurred approximately 0.19°C and 0.17°C earlier, alongside improved sweating sensitivity with exercise. MCAv decreased during heating (P < 0.005), but was maintained 4.5 cm/s (3.6, 5.5; P < 0.005) higher during heating after exercise compared with control (0.6 cm/s [-0.4, 1.4]). Exercise training that improves cardiorespiratory fitness reduces self-reported hot flushes. Improvements are likely mediated through greater thermoregulatory control in response to increases in core temperature and enhanced vascular function in the cutaneous and cerebral circulations.
Luo, Xia; Jellison, Kristen L; Huynh, Kevin; Widmer, Giovanni
2015-01-01
Multiple rotating annular reactors were seeded with biofilms flushed from water distribution systems to assess (1) whether biofilms grown in bioreactors are representative of biofilms flushed from the water distribution system in terms of bacterial composition and diversity, and (2) whether the biofilm sampling method affects the population profile of the attached bacterial community. Biofilms were grown in bioreactors until thickness stabilized (9 to 11 weeks) and harvested from reactor coupons by sonication, stomaching, bead-beating, and manual scraping. High-throughput sequencing of 16S rRNA amplicons was used to profile bacterial populations from flushed biofilms seeded into bioreactors as well as biofilms recovered from bioreactor coupons by different methods. β diversity between flushed and reactor biofilms was compared to β diversity between (i) biofilms harvested from different reactors and (ii) biofilms harvested by different methods from the same reactor. These analyses showed that average diversity between flushed and bioreactor biofilms was double the diversity between biofilms from different reactors operated in parallel. The diversity between bioreactors was larger than the diversity associated with different biofilm recovery methods. Compared to other experimental variables, the method used to recover biofilms had a negligible impact on the outcome of water biofilm analyses based on 16S amplicon sequencing. Results from this study show that biofilms grown in reactors over 9 to 11 weeks are not representative models of the microbial populations flushed from a distribution system. Furthermore, the bacterial population profile of biofilms grown in replicate reactors from the same flushed water are likely to diverge. However, four common sampling protocols, which differ with respect to disruption of bacterial cells, provide similar information with respect to the 16S rRNA population profile of the biofilm community.
FLUSH - PREDICTION OF FLOW PARAMETERS OF SLUSH HYDROGEN
NASA Technical Reports Server (NTRS)
Hardy, T.
1994-01-01
Slush hydrogen, a mixture of the solid and liquid phases of hydrogen, is a possible source of fuel for the National Aerospace Plane (NASP) Project. Advantages of slush hydrogen over liquid hydrogen include greater heat capacity and greater density. However, practical use of slush hydrogen as a fuel requires systems of lines, valves, etc. which are designed to deliver the fuel in slush form with minimal solid loss as a result of pipe heating or flow friction. Engineers involved with the NASP Project developed FLUSH to calculate the pressure drop and slush hydrogen solid fraction loss for steady-state, one-dimensional flow. FLUSH solves the steady-state, one-dimensional energy equation and the Bernoulli equation for pipe flow. The program performs these calculations for each two-node element--straight pipe length, elbow, valve, fitting, or other part of the piping system--specified by the user. The user provides flow rate, upstream pressure, initial solid hydrogen fraction, element heat leak, and element parameters such as length and diameter. For each element, FLUSH first calculates the pressure drop, then figures the slush solid fraction exiting the element. The code employs GASPLUS routines to calculate thermodynamic properties for the slush hydrogen. FLUSH is written in FORTRAN IV for DEC VAX series computers running VMS. An executable is provided on the tape. The GASPLUS physical properties routines which are required for building the executable are included as one object library on the program media (full source code for GASPLUS is available separately as COSMIC Program Number LEW-15091). FLUSH is available in DEC VAX BACKUP format on a 9-track 1600 BPI magnetic tape (standard media) or on a TK50 tape cartridge. FLUSH was developed in 1989.
Contamination removal by CO2 jet spray
NASA Astrophysics Data System (ADS)
Peterson, Ronald V.; Bowers, Charles W.
1990-11-01
Studies on the effectiveness of the jet flush in removing particle fallout and Arizona-standard fine dust on polished optical substrates have been carried out at ambient pressure and vacuum. These studies have shown that the CO2 jet flush is a viable method for removing contaminants from optical surfaces with no damage to the surface. The studies also show that the jet flush has potential for use as an on-orbit cleaning device for space optics.
Water Efficient Installations - A New Army Guidance Document
2010-06-01
Toilets 1.28 gpf or less, 50 manuf., 500+ models Required in CA Dual flush options also available WaterSense program provides certification and...lose 8760 to 219,000 gal/year Broken flush valve on toilet can lose 40 gal/hour US Army Corps of Engineers® Engineer Research and Development Center...Engineer Research and Development Center Toilets and Urinals ULFTs Ultra-Low Flush Toilet , also called low flow 1.28 gpf to 1.6 gpf HETs High Efficiency
Effect of aerobic training on hot flushes and quality of life—a randomized controlled trial
Luoto, Riitta; Moilanen, Jaana; Heinonen, Reetta; Mikkola, Tomi; Raitanen, Jani; Tomas, Eija; Ojala, Katriina; Mansikkamäai, Kirsi; Nygård, Clas-Håkan
2012-01-01
Background and objective. To estimate whether aerobic training has an effect on frequency of hot flushes or quality of life. Design. A randomized controlled trial. Participants and setting. Symptomatic, sedentary women (n = 176), 43–63 years, no current use of hormone therapy. Intervention. Unsupervised aerobic training for 50 minutes four times per week during 6 months. Outcomes. Hot flushes as measured with Women's Health Questionnaire (WHQ) and Health-Related Quality of Life (HRQoL, SF-36), daily reported hot flushes on phone-based diary, cardiorespiratory fitness (CRF), and body composition. Results. Intervention group had larger decrease in the frequency of night-time hot flushes based on phone diary (P for month X group = 0.012), but not on WHQ scale. Intervention group had less depressed mood (P= 0.01) than control women according to change in WHQ score. Changes in WHQ score in depressed mood (P = 0.03) and menstrual symptoms (P=0.01) in the intervention group were significantly dependent on frequency of training sessions. HRQoL was improved among the intervention group women in physical functioning (P= 0.049) and physical role limitation (P= 0.017). CRF improved (P= 0.008), and lean muscle mass increased (P= 0.046) significantly in the intervention group as compared to controls. Conclusions. Aerobic training may decrease the frequency of hot flushes and improve quality of life among slightly overweight women. PMID:21639722
NASA Astrophysics Data System (ADS)
Sung, Menghau; Teng, Chun-Hao; Yang, Tsung-Hsien
2017-07-01
Soil flushing using micro-nano-sized bubbles (MNB) in water as the flushing solution was tested in laboratory sand columns for the cleanup of residual trichloroethene (TCE) non-aqueous-phase-liquid (NAPL). Experiments considering flushing with MNB as well as ozone MNB (OZMNB) in water to treat soils contaminated with residual TCE liquid were conducted to examine effects of ozone on dissolution enhancement. The degrees of residual TCE saturation in soils, ranging from 0.44% to 7.6%, were tested. During flushings, aqueous TCE concentrations at the column exit were monitored and TCE masses remained in the columns after flushing were determined. Experimental results between runs with MNB and OZMNB in water revealed that dissolution enhancement was dependent on residual saturation conditions, and the maximum enhancement was around 9%. Governing equations consisting of three coupled partial differential equations (PDEs) were developed to model the system, and high-order finite difference (HOFD) method was employed to solve these PDEs. From mathematical modeling of reactive mass transfer under low residual saturation conditions (0.44% and 1.9%), experimental data were simulated and important controlling mechanisms were identified. It was concluded that a specific parameter pertinent to NAPL-water interfacial area in the Sherwood number had to be modified to satisfactorily describe the dissolution of TCE in the presence of MNB in water.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Maienschein, J.L.; Garcia, F.; Garza, R.G.
Tritium-handling apparatus has been decontaminated as part of the shutdown of the LLNL Tritium Facility. Two stainless-steel gloveboxes that had been used to process lithium deuteride-tritide (LiDT) salt were decontaminated using the Portable Cleanup System so that they could be flushed with room air through the facility ventilation system. Further surface decontamination was performed by scrubbing the interior with paper towels and ethyl alcohol or Swish{trademark}. The surface contamination, as shown by swipe surveys, was reduced from 4{times}10{sup 4}--10{sup 6} disintegrations per minute (dpm)/cm{sup 2} to 2{times}10{sup 2}--4{times}10{sup 4} dpm/cm{sup 2}. Details on the decontamination operation are provided. A seriesmore » of metal (palladium and vanadium) hydride storage beds have been drained of tritium and flushed with deuterium in order to remove as much tritium as possible. The bed draining and flushing procedure is described, and a calculational method is presented which allows estimation of the tritium remaining in a bed after it has been drained and flushed. Data on specific bed draining and flushing are given.« less
Liu, Weijie; Hao, Yan; Jiang, Jihong; Zhu, Aihua; Zhu, Jingrong; Dong, Zhen
2016-10-01
In this study, bioflocculant produced by Pseudomonas veronii L918 was applied to treat ash-flushing wastewater. The strain L918 could convert the hydrolyzate of peanut hull into bioflocculant, which can effectively reduce the production cost of bioflocculant. The yield of 3.39g/L bioflocculant MBF-L918 was achieved when 300mL/L peanut hull hydrolyzate was used as carbon source. The bioflocculant MBF-L918 contains 77.14% polysaccharides and 4.84% proteins, and the molecular weight (MW) of MBF-L918 is 24.77kDa. Furthermore, MBF-L918 showed good flocculating efficiency of 92.51% to ash-flushing wastewater when 2.83mg/L MBF-L918 was added, and thus achieved the recycling of ash-flushing wastewater. This study reported for the first time that the bioflocculant was produced using peanut hull hydrolyzate and effectively applied in the treatment of coal ash-flushing wastewater. Copyright © 2016 Elsevier Ltd. All rights reserved.
Heparin or 0.9% sodium chloride to maintain central venous catheter patency: a randomized trial.
Schallom, Marilyn E; Prentice, Donna; Sona, Carrie; Micek, Scott T; Skrupky, Lee P
2012-06-01
To compare heparin (3 mL, 10 units/mL) and 0.9% sodium chloride (NaCl, 10 mL) flush solutions with respect to central venous catheter lumen patency. Single-center, randomized, open label trial. Medical intensive care unit and Surgical/Burn/Trauma intensive care unit at Barnes-Jewish Hospital, St. Louis, MO. Three hundred forty-one patients with multilumen central venous catheters. Patients with at least one lumen with a minimum of two flushes were included in the analysis. Patients were randomly assigned within 12 hrs of central venous catheter insertion to receive either heparin or 0.9% sodium chloride flush. The primary outcome was lumen nonpatency. Secondary outcomes included the rates of loss of blood return, inability to infuse or flush through the lumen (flush failure), heparin-induced thrombocytopenia, and catheter-related blood stream infection. Assessment for patency was performed every 8 hrs in lumens without continuous infusions for the duration of catheter placement or discharge from intensive care unit. Three hundred twenty-six central venous catheters were studied yielding 709 lumens for analysis. The nonpatency rate was 3.8% in the heparin group (n = 314) and 6.3% in the 0.9% sodium chloride group (n = 395) (relative risk 1.66, 95% confidence interval 0.86-3.22, p = .136). The Kaplan-Meier analysis for time to first patency loss was not significantly different (log rank = 0.093) between groups. The rates of loss of blood return and flush failure were similar between the heparin and 0.9% sodium chloride groups. Pressure-injectable central venous catheters had significantly greater rates of nonpatency (10.6% vs. 4.3%, p = .001) and loss of blood return (37.0% vs. 18.8%, p <.001) compared to nonpressure-injectable catheters. The frequencies of heparin-induced thrombocytopenia and catheter-related blood stream infection were similar between groups. 0.9% sodium chloride and heparin flushing solutions have similar rates of lumen nonpatency. Given potential safety concerns with the use of heparin, 0.9% sodium chloride may be the preferred flushing solution for short-term use central venous catheter maintenance.
Vinik, A I; Gonin, J; England, B G; Jackson, T; McLeod, M K; Cho, K
1990-06-01
We examined the role of the potent vasoactive kinin substance-P (SP) in flushing derived from various causes. SP was measured in plasma after acetone/ether extraction using an antiserum directed at the carboxy-terminal 5-11 amino acid region of undecapeptide SP. The antiserum had less than 1% cross-reaction with the other neurokinins, neurokinin-A and neuropeptide-K, that derive from the beta-preprotachykinin gene and share carboxy-terminal residues. Basal and pentagastrin-stimulated SP levels were measured in 22 healthy controls, 11 patients with histologically proven carcinoid tumors, 8 patients with tumors other than carcinoid, and 7 patients with idiopathic flushing (IF). Basal SP levels were less than 10 pg/mL in normal subjects. All patients with midgut carcinoid tumors had SP levels greater than 25 pg/mL, as did 7 of 8 patients with noncarcinoid tumors and 5 of 7 patients with IF. Using 50 pg/mL as the cutoff point, the sensitivity was 63% for detection of a tumor, and 100% of nontumor patients were excluded. Pentagastrin administration uniformly induced flushing and caused a rise in SP levels greater than 150 pg/mL in 5 of 10 patients with carcinoid tumors, 3 of 8 with noncarcinoid tumors, and 0 of 7 with IF, i.e. a SP rise of more than 100 pg/mL suggests a tumor. Administration of somatostatin (150 micrograms) 0.5 h before the pentagastrin abolished flushing in all carcinoid patients and reduced SP levels, but not into the normal range. Long term treatment with SMS significantly reduced flushing and lowered SP levels, but did not restore these to normal. We conclude that 90% of patients with carcinoid/noncarcinoid tumor have raised COOH-terminal SP levels. A basal level above 50 pg/mL or a pentagastrin-stimulated rise of more than 100 pg/mL distinguishes carcinoid from IF. The dissociation between SP concentrations and flushing suggests that SP may not be the only kinin involved in the flushing associated with carcinoid tumors.
Seasonality of Central Amazon Forest Leaf Flush Using Tower-Mounted RGB Camera
NASA Astrophysics Data System (ADS)
Wu, J.; Nelson, B. W.; Tavares, J. V.; Valeriano, D. M.; Lopes, A. P.; Marostica, S. F.; Martins, G.; Prohaska, N.; Albert, L.; De Araujo, A. C.; Manzi, A. O.; Saleska, S. R.; Huete, A. R.
2014-12-01
Tower-mounted RGB cameras can contribute data to the debate on seasonality of photosynthesis in Amazon upland forests and to improved modelling of forest response to climate change. In late 2010 we began monitoring upper crown surfaces of ~65 living trees or vines from a 54m tall eddy-flux tower on a well-drained clay-soil plateau. This Central Amazon site (60.2091 W, 2.6092 S) is in a large forest reserve. We deployed a Stardot Netcam XL RGB camera with a 1024 x 768 resolution CMOS sensor, 66o HFOV lens, fixed oblique south view, fixed iris, fixed white balance and auto-exposure. Images were logged every 15 seconds to a passively cooled FitPC2i with heat-tolerant SSD drive. Camera and PC automatically rebooted after power outages. Here we report results for two full years, from 1 Dec 2011 through 30 Nov 2013. Images in six day intervals were selected near local noon for homogeneous diffuse lighting under cloudy sky and for a standard reflected radiance (± 10%). Crowns showing two easily recognized phenophases were tallied: (1) massive flushing of new light-green leaves and (2) complete or nearly complete leaf loss. On average, 60% of live crowns flushed a massive amount of new leaves each year. Each crown flush was completed within 30 days. During the five driest months (Jun-Oct), 44% of all live crowns, on average, exhibited such massive leaf flush. In the five wettest months (Dec-Apr) only 11% of live crowns mass-flushed new leaves. In each year 23% of all live crowns became deciduous, usually a brief (1-2 week) preamble to flushing. Additional crowns lost old dark-green leaves partially and more gradually, becoming semi-deciduous prior to flushing. From these two years of camera data we infer that highly efficient leaves of 2-6 months age (high maximum carboxylation rate) are most abundant from the late dry season (October) through the mid wet season (March). This coincides with peak annual photosynthesis (Gross Ecosystem Productivity) reported for this same Central Amazon site using eddy flux methods.
A Novel Animal Model to Study Hot Flashes: No Effect of GnRH
Albertson, Asher J.; Skinner, Donal C.
2009-01-01
Menopausal hot flushes compromise the quality of life for the majority of women. The physiological mechanisms underlying hot flushes remain poorly understood and the absence of an animal model to investigate hot flushes hinders investigations in this field. We have developed the sheep as a model to study peripheral skin temperature changes. Subjecting sheep to fever-inducing treatments with lipopolysaccharide, a significant (P<0.01) change in ear skin temperature was observed. As a strong correlation between luteinizing hormone pulses and hot flushes has previously been reported, we then determined whether intravenous gonadotropin-releasing hormone (GnRH), at doses sufficient to elevate CSF GnRH concentrations, could modulate ear skin temperature. No effect was observed, suggesting that GnRH per se dose not play a role in the etiology of hot flashes. PMID:19512948
Hamze, Benjamin; Vaillancourt, Régis; Sharp, Diane; Villarreal, Gilda
2016-01-01
The aim of this randomized single-blind study is to compare taste and odor disturbances in patients receiving 0.9% sodium chloride flushes from 2 brands. Seventy-five patients from 6 to 18 years of age received intravenous 0.9% sodium chloride infusions, and 50 healthy volunteers who tasted the 2 brands of 0.9% sodium chloride from prefilled syringes were assessed for taste and/or odor disturbances. Taste or odor disturbances were equally present in patients flushed with MedXL and Becton-Dickinson 0.9% sodium chloride. Disturbances are more frequent when 0.9% sodium chloride is flushed through central venous access devices than through peripheral catheters. No difference between the brands was found when healthy volunteers tasted it orally.
Redefining the stormwater first flush phenomenon.
Bach, Peter M; McCarthy, David T; Deletic, Ana
2010-04-01
The first flush in urban runoff has been an important, yet disputed phenomenon amongst many researchers. The vast differences in the evidence could be solely due to limitations of the first flush current definition and the approach used for its assessment. There is a need for revisiting the first flush theory in the light of its practical applications to urban drainage management practices. We propose that a catchment's first flush behaviour is to be quantified by the runoff volume required to reduce a catchment's stormwater pollutant concentrations to background levels. The proposed method for assessment of this runoff volume starts by finding the average catchment pollutant concentrations for a given increment of discharged volume using a number of event pollutographs. Non-parametric statistics are then used to establish the characteristic pollutograph by pooling statistically indifferent runoff increments (known as slices) together. This allows the identification of the catchment's initial and background pollutant concentrations and for quantification of the first flush volume and its strength. The novel technique was used on seven catchments around Melbourne, Australia, with promising results. Sensitivity to the chosen increment of runoff (for which mean concentrations are calculated) indicated that when dealing with discrete flow-weighted water quality data, a suitable slice size should closely match the flow-weighting of samples. The overall sensitivity to runoff increment and level of significance was found to be negligible. Further research is needed to fully develop this method. Copyright (c) 2010 Elsevier Ltd. All rights reserved.
Perrin, Magali; Rossi, Sergio; Isabel, Nathalie
2017-05-01
Bud and cambial phenology represent the adaptation of species to the local environment that allows the growing season to be maximized while minimizing the risk of frost for the developing tissues. The temporal relationship between the apical and radial meristems can help in the understanding of tree growth as a whole process. The aim of this study was to compare cambial phenology in black spruce (Picea mariana (Mill.) B.S.P.) provenances classified as early and late bud flushing. The different phases of cambial phenology were assessed on wood microcores sampled weekly from April to October in 2014 and 2015 from 61 trees growing in a provenance trial in Quebec, Canada. Trees showing an early bud flush also exhibited early reactivation of xylem differentiation, although an average difference of 12 days for buds corresponded to small although significant differences of 4 days for xylem. Provenances with early bud flush had an early bud set and completed xylem formation earlier than late bud flush provenances. No significant difference in the period of xylem formation and total growth was observed between the flushing classes. Our results demonstrate that the ecotype differentiation of black spruce provenances represented by the phenological adaptation of buds to the local climate corresponds to specific growth dynamics of the xylem. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Espa, Paolo; Brignoli, Maria Laura; Crosa, Giuseppe; Gentili, Gaetano; Quadroni, Silvia
2016-11-01
Sediment flushing may be effective to preserve reservoir storage, but concerns arise about sustainability for downstream freshwater ecosystems. We report on the controlled flushing of approximately 110,000 tons of silt from a 120 Mm(3) reservoir on the Adda River, the main tributary of Lake Como, Italy. Technical constraints prevented flushing during high flows, and the operation had to be spread out over three consecutive years (2010-2012) and, for each year, over a rather long time span (40-50 days). To mitigate the downstream impact, the suspended sediment concentration (SSC) of the evacuated water was controlled by regulating the dislodging works inside the reservoir, increasing the streamflow in the regulated tributaries, and operating an instream settling basin. SSC and water flow as well as benthic macroinvertebrates and trout were monitored as far as 28 km below the reservoir. At the most upstream gauging station, SSC peaked up to 100 g/l and ranged from 3.5 to 8 g/l on average per each operation. Stream quality metrics based on macroinvertebrate data evidenced the impairment due to flushing; however, the benthic community showed high resilience, recovering to pre-flushing conditions in 6-9 months. Trout data were biased by stocking and sport fishing and were more difficult to be interpreted. The trout population wouldn't seem remarkably altered, even if a non-negligible impact could be deduced through pre/post-event sample comparison. Copyright © 2016. Published by Elsevier Ltd.
Laboratory Investigations for the Role of Flushing Media in Diamond Drilling of Marble
NASA Astrophysics Data System (ADS)
Bhatnagar, A.; Khandelwal, Manoj; Rao, K. U. M.
2011-05-01
Marble is used as a natural stone for decorative purposes from ages. Marble is a crystalline rock, composed predominantly of calcite, dolomite or serpentine. The presence of impurities imparts decorative pattern and colors. The diamond-based operations are extensively used in the mining and processing of marble. Marble is mined out in the form of blocks of cuboids shape and has to undergo extensive processing to make it suitable for the end users. The processing operation includes slabbing, sizing, polishing, etc. Diamond drilling is also commonly used for the exploration of different mineral deposits throughout the world. In this paper an attempt has been made to enhance the performance of diamond drilling on marble rocks by adding polyethylene-oxide (PEO) in the flushing water. The effect of PEO added with the drilling water was studied by varying different machine parameters and flushing media concentration in the laboratory. The responses were rate of penetration and torque at bit-rock interface. Different physico-mechanical properties of marble were also determined. It was found that flushing water added with PEO can substantially enhance the penetration rates and reduce the torque developed at the bit-rock interface as compared to plain flushing water.
Cysneiros, Denise; Banks, Charles J; Heaven, Sonia; Karatzas, Kimon-Andreas G
2012-11-01
The effect of hydraulic flush and pH control on hydrolysis, Volatile Fatty Acids (VFA) production and profile in anaerobic leach bed reactors was investigated for the first time. Six reactors were operated under different regimes for two consecutive batches of 28days each. Buffering at pH ∼6.5 improved hydrolysis (Volatile Solid (VS) degradation) and VFA production by ∼50%. Butyric and acetic acid were dominant when reactors were buffered, while only butyric acid was produced at low pH. Hydraulic flush enhanced VS degradation and VFA production by ∼15% and ∼32%, respectively. Most Probable Number (MPN) of cellulolytic microorganisms indicated a wash out when hydraulic flush was applied, but pH control helped to counteract this. The highest VS degradation (∼89%), VFA yield (0.84kgCODkg(-1)VS(added)) and theoretical methane potential (0.37m(3)CH(4)kg(-1)VS(added)) were obtained when pH control and hydraulic flush were applied, and therefore, these conditions are recommended. Copyright © 2012 Elsevier Ltd. All rights reserved.
Role of HCA₂ (GPR109A) in nicotinic acid and fumaric acid ester-induced effects on the skin.
Hanson, Julien; Gille, Andreas; Offermanns, Stefan
2012-10-01
Nicotinic acid (NA) and fumaric acid esters (FAE) such as monomethyl fumarate or dimethyl fumarate are drugs that elicit a cutaneous reaction called flushing as a side effect. NA is used to reduce progression of atherosclerosis through its anti-dyslipidemic activity and lipid-independent mechanisms involving immune cells, whereas FAE are used to treat psoriasis via largely unknown mechanisms. Both, NA and FAE, induce flushing by the activation of the G-protein-coupled receptor (GPCR) Hydroxy-carboxylic acid receptor 2 (HCA₂, GPR109A) in cells of the epidermis. While the wanted effects of NA are at least in part also mediated by HCA₂, it is currently not clear whether this receptor is also involved in the anti-psoriatic effects of FAE. The HCA₂-mediated flushing response to these drugs involves the formation of prostaglandins D₂ and E₂ by Langerhans cells and keratinocytes via COX-1 in Langerhans cells and COX-2 in keratinocytes. This review summarizes recent progress in the understanding of the mechanisms underlying HCA₂-mediated flushing, describes strategies to mitigate it and discusses the potential link between flushing, HCA₂ and the anti-psoriatic effects of FAE. Copyright © 2012 Elsevier Inc. All rights reserved.
Toilets Specification and Certification
Recent advancements have allowed toilets to use 1.28 gallons per flush or less while still providing equal or superior performance. This is 20 percent less water than the current federal standard of 1.6 gallons per flush.
30 CFR 57.7807 - Flushing the combustion chamber.
Code of Federal Regulations, 2011 CFR
2011-07-01
... and Rotary Jet Piercing Rotary Jet Piercing-Surface Only § 57.7807 Flushing the combustion chamber. The combustion chamber of a jet drill stem which has been sitting unoperated in a drill hole shall be...
30 CFR 57.7807 - Flushing the combustion chamber.
Code of Federal Regulations, 2010 CFR
2010-07-01
... and Rotary Jet Piercing Rotary Jet Piercing-Surface Only § 57.7807 Flushing the combustion chamber. The combustion chamber of a jet drill stem which has been sitting unoperated in a drill hole shall be...
A selective estrogen receptor modulator for the treatment of hot flushes.
Wallace, Owen B; Lauwers, Kenneth S; Dodge, Jeffrey A; May, Scott A; Calvin, Joel R; Hinklin, Ronald; Bryant, Henry U; Shetler, Pamela K; Adrian, Mary D; Geiser, Andrew G; Sato, Masahiko; Burris, Thomas P
2006-02-09
A selective estrogen receptor modulator (SERM) for the potential treatment of hot flushes is described. (R)-(+)-7,9-difluoro-5-[4-(2-piperidin-1-ylethoxy)phenyl]-5H-6-oxachrysen-2-ol, LSN2120310, potently binds ERalpha and ERbeta and is an antagonist in MCF-7 breast adenocarcinoma and Ishikawa uterine cancer cell lines. The compound is a potent estrogen antagonist in the rat uterus. In ovariectomized rats, the compound lowers cholesterol, maintains bone mineral density, and is efficacious in a morphine dependent rat model of hot flush efficacy.
Performance Characteristics of Flush and Shielded Auxiliary Exits at Mach Numbers of 1.5 to 2.0
NASA Technical Reports Server (NTRS)
Abdalla, Kaleel L.
1959-01-01
The performance characteristics of several flush and shielded auxiliary exits were investigated at Mach numbers of 1.5 to 2.0, and jet pressure ratios from jet off to 10. The results indicate that the shielded configurations produced better overall performance than the corresponding flush exits over the Mach-number and pressure-ratio ranges investigated. Furthermore, the full-length shielded exit was highest in performance of all the configurations. The flat-exit nozzle block provided considerably improved performance compared with the curved-exit nozzle block.
Domanin, Maurizio; Miloro, Riccardo; Romagnoli, Silvia; Basellini, Aldo
2018-03-01
Guidelines now recommend endovenous thermal ablation over open treatment of saphenous incompetence, but flush saphenofemoral ligation and stripping remain relevant when appropriately applied and expertly executed. Complications are rare but could be severe, needing further surgical correction. We report a unique case of a late venous pseudoaneurysm of the great saphenous vein stump after flush saphenofemoral ligation and stripping, successfully treated with surgical sac excision. We highlight the importance of continuous follow-up for patients previously submitted to open venous surgery.
2010-11-30
approved climate zones) ► Dual flush toilets ► 1.5 GPM flow shower heads ► 0.5 GPM flow faucets ► Rainwater harvesting ► Permeable asphalt, permeable...for system with indirect evaporative pre-cooling Sustainability Measures ► Dual flush toilets ► 1.5 GPM flow shower heads, 0.5 GPM flow faucets...daylighting controls with 500 lux setpoint ► Dual flush toilets ►Waterless urinals ► 0.5 GPM flow faucets ► Rainwater harvesting ► Enhanced Commissioning
Hussain, Faruqe; Clasen, Thomas; Akter, Shahinoor; Bawel, Victoria; Luby, Stephen P; Leontsini, Elli; Unicomb, Leanne; Barua, Milan Kanti; Thomas, Brittany; Winch, Peter J
2017-05-25
In rural Bangladesh, India and elsewhere, pour-flush pit latrines are the most common sanitation system. When a single pit latrine becomes full, users must empty it themselves and risk exposure to fresh feces, pay an emptying service to remove pit contents or build a new latrine. Double pit pour-flush latrines may serve as a long-term sanitation option including high water table areas because the pits do not need to be emptied immediately and the excreta decomposes into reusable soil. Double pit pour-flush latrines were implemented in rural Bangladesh for 'hardcore poor' households by a national NGO, BRAC. We conducted interviews, focus groups, and spot checks in two low-income, rural areas of Bangladesh to explore the advantages and limitations of using double pit latrines compared to single pit latrines. The rural households accepted the double pit pour-flush latrine model and considered it feasible to use and maintain. This latrine design increased accessibility of a sanitation facility for these low-income residents and provided privacy, convenience and comfort, compared to open defecation. Although a double pit latrine is more costly and requires more space than a single pit latrine the households perceived this sanitation system to save resources, because households did not need to hire service workers to empty pits or remove decomposed contents themselves. In addition, the excreta decomposition process produced a reusable soil product that some households used in homestead gardening. The durability of the latrine superstructures was a problem, as most of the bamboo-pole superstructure broke after 6-18 months of use. Double pit pour-flush latrines are a long-term improved sanitation option that offers users several important advantages over single pit pour-flush latrines like in rural Bangladesh which can also be used in areas with high water table. Further research can provide an understanding of the comparative health impacts and effectiveness of the model in preventing human excreta from entering the environment.
Flow cytometry for immediate follow-up of drinking water networks after maintenance.
Van Nevel, Sam; Buysschaert, Benjamin; De Roy, Karen; De Gusseme, Bart; Clement, Lieven; Boon, Nico
2017-03-15
Drinking water networks need maintenance every once in a while, either planned interventions or emergency repairs. When this involves opening of the water pipes, precautionary measures need to be taken to avoid contamination of the drinking water at all time. Drinking water suppliers routinely apply plating for faecal indicator organisms as quality control in such a situation. However, this takes at least 21 h of waiting time, which can be crucial when dealing with major supply pipes. A combination of flow cytometric (FCM) bacterial cell counts with FCM fingerprinting techniques is proposed in this study as a fast and sensitive additional technique. In three full scale situations, major supply pipes with 400-1050 mm diameter were emptied for maintenance, shock-chlorinated and flushed with large amounts of clean drinking water before taking back in operation. FCM measurements of the discharged flushing water revealed fast lowering and stabilizing bacterial concentrations once flushing is initiated. Immediate comparison with clean reference drinking water used for flushing was done, and the moment when both waters had similar bacterial concentrations was considered as the endpoint of the necessary flushing works. This was usually after 2-4 h of flushing. FCM fingerprinting, based on both bacteria and FCM background, was used as additional method to verify how similar flushing and reference samples were and yielded similar results. The FCM approved samples were several hours later approved as well by the drinking water supplier after plating and incubation for total Coliforms and Enterococci. These were used as decisive control to set the pipes back in operation. FCM proved to be a more conservative test than plating, yet it yielded immediate results. Application of these FCM methods can therefore avoid long unnecessary waiting times and large drinking water losses. Copyright © 2016 Elsevier Ltd. All rights reserved.
Modeling the Flushing Response to the Construction of a Low Crested Weir in the Banana River
NASA Astrophysics Data System (ADS)
Saberi, A.; Weaver, R. J.
2014-12-01
The ADCIRC hydrodynamic model coupled with a Lagrangian Particle Tracking Model (LPTM) is applied to study circulation in the Banana River. The purpose of this study is to determine the extent to which constructing a low crested weir adjacent to Port Canaveral can improve flushing in this region. The Banana River a 50 km long sub-basin of the Indian River Lagoon (IRL), located on the central-east coast of Florida in Brevard County between Cape Canaveral and Merritt Island. Although Banana River has an outlet to the ocean through the Port Canaveral locks, the locks remain closed when there is no passing vessel resulting in limited circulation, long flushing time and poor water quality. Recent high mortality events of different species, e.g. dolphins, manatees and pelicans in the lagoon ecosystem, can be linked to the decline in the water quality. ADCIRC is used to simulate the hydrodynamic properties of the study area and determine the 2D depth-averaged velocity field for two separate cases: one with only tidal and another with both tidal and meteorological forces considered. Simulations are run, first to establish the baseline hydrodynamics of the unmodified system, and then to predict the effects of modifying the domain. Passive particles are placed in the Banana River portion of our domain, and the movement of these particles is tracked using LPTM for both cases. Flushing and residence time are then computed. Results indicate an improvement in flushing in both the Banana River and the central Indian River Lagoon, driven by an induced southerly current. In the portion of the Banana River to the south of the port complex, tidal flushing time is significantly reduced for the case of modified domain. In this southern region the flushing time based on 50% renewal time, is decreased from 100 days down to 15 days, after the addition of the weir to the domain.
How to Dispose of Unused Medicines
... trash and recycling facility. Flushing Drugs and the Water Supply Some people wonder if it’s okay to flush ... such as rivers and lakes, and in drinking water supplies. “The main way drug residues enter water systems ...
40 CFR 141.803 - Coliform sampling.
Code of Federal Regulations, 2013 CFR
2013-07-01
... the disinfection and flushing frequency recommended by the aircraft water system manufacturer, when... of the aircraft water system is unrestricted. (e) Post disinfection and flushing follow-up sampling....803 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED...
40 CFR 141.803 - Coliform sampling.
Code of Federal Regulations, 2014 CFR
2014-07-01
... the disinfection and flushing frequency recommended by the aircraft water system manufacturer, when... of the aircraft water system is unrestricted. (e) Post disinfection and flushing follow-up sampling....803 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED...
INTERIOR VIEW OF THE PANTRY. SHOWING THE ORIGINAL FLUSH WOOD ...
INTERIOR VIEW OF THE PANTRY. SHOWING THE ORIGINAL FLUSH WOOD CABINET DOORS AND ORIGINAL BIN PULLS ON DRAWERS. VIEW FACING SOUTHWEST. - Hickam Field, Officers' Housing Type L, 702 Julian Avenue, Honolulu, Honolulu County, HI
Simpkins, D.G.; Hubert, W.A.; Wesche, T.A.
2000-01-01
The controlled release of dammed water, designed to produce a flushing flow that would remove fine sediments from spawning habitat in a flow-regulated river, did not displace juvenile rainbow trout Oncorhynchus mykiss (20-25 cm total length) downstream. Of eight naturally spawned (wild) and nine hatchery fish that were radio-tagged, only one wild fish and two hatchery fish were found in different locations after an eight-fold increase in flow. These three fish moved upstream and the greatest movement was 96 m. Cobble and boulder substrates in main-channel pools were thought to provide slow-water-velocity refuges during the flushing flow. Our findings and the findings of other researchers suggest that flushing flows can be conducted to enhance spawning habitat for rainbow trout without causing extensive downstream movements or habitat displacement of small fish in regulated rivers.
NASA Technical Reports Server (NTRS)
Larson, T. J.; Flechner, S. G.; Siemers, P. M., III
1980-01-01
The results of a wind tunnel investigation on an all flush orifice air data system for use on a KC-135A aircraft are presented. The investigation was performed to determine the applicability of fixed all flush orifice air data systems that use only aircraft surfaces for orifices on the nose of the model (in a configuration similar to that of the shuttle entry air data system) provided the measurements required for the determination of stagnation pressure, angle of attack, and angle of sideslip. For the measurement of static pressure, additional flush orifices in positions on the sides of the fuselage corresponding to those in a standard pitot-static system were required. An acceptable but less accurate system, consisting of orifices only on the nose of the model, is defined and discussed.
Seventy-two hours hypothermic intestinal preservation study using a new perfluorocarbon emulsion.
DeRoover, A; Krafft, M P; Deby-Dupont, G; Riess, J; Jacquet, N; Lamy, M; Meurisse, M; D'Silva, M
2001-05-01
We investigated the effect of a perfluorocarbon emulsion (FC) added to the University of Wisconsin (UW) solution on hypothermic (4 degrees C, 12-72h) preservation of rat small bowel grafts. The FC was 90%w/v perfluorooctylbromide, 2%w/v egg yolk phospholipids and 1.4%w/v mixed fluorocarbon-hydrocarbon molecular dowels. Four groups were defined: [1] UW flush and UW storage; [2] UW flush and FC storage; [3] flush with FC diluted 2 times with UW (FU) and FU storage; [4] FU flush and storage in oxygenated FU. Preservation was estimated with a histological score based on villus epithelium adhesion, on villus sloughing and on crypt cell adhesion to the basal membrane. Antioxidant potential was estimated by measurement of total thiol functions (SH) and activities of glutathione-peroxidase (GSH-P), superoxide dismutase (SOD) and catalase. FC in flush improved preservation during the first 24h (p<0.01). Storage in FC appeared superior to UW for the first 24h (p<0.01). Oxygenation (100% O2) of the storage medium yielded superior results at 12h and 24h (p<0.01 and p<0.001 versus group [1] respectively). After 72h, SOD and catalase activities increased in groups [3] and [4], and SOD decreased in group [1] (p<0.05). SH progressively decreased in group [1] (p<0.05) and GSH-P increased at 24 and 48h in groups [3] and [4] (p<0.01). The increase of O2 in the perfusion flush or storage medium ameliorated the preservation status and protected the antioxidant potential of the small bowel.
Goodwin, Carl R.
1991-01-01
Decades of dredging and filling of Florida's low-lying coastal wetlands have produced thousands of miles of residential tidal canals and adjacent waterfront property. Typically, these canals are poorly flushed, and over time, accumulated organic-rich bottom materials, contribute to an increasingly severe degraded water quality. One-dimensional hydrodynamic and constituent-transport models were applied to two dead-end canal systems to determine the effects of canal system interconnection using tide gates on water circulation and constituent flushing. The model simulates existing and possible future circulation and flushing conditions in about 29 miles of the approximately 130 miles of tidally influenced canals in Cape Coral, located on the central west coast of peninsular Florida. Model results indicate that tidal water-level differences between the two canal systems can be converted to kinetic energy, in the form of increased water circulation, but the use of one-way tide gate interconnections. Computations show that construction of from one to four tide gates will cause replacement of a volume of water equivalent to the total volume of canals in both systems in 15 to 9 days, respectively. Because some canals flush faster than others, 47 and 21 percent of the original canal water will remain in both systems 50 days after start of operation of one and four tide gates, respectively. Some of the effects that such increased flushing are expected to have include reduced density stratification and associated dissolved-oxygen depletion in canal bottom waters, increased localized reaeration, and more efficient discharge of stormwater runoff entering the canals.
The impact of recreational boat traffic on Marbled Murrelets (Brachyramphus marmoratus).
Bellefleur, Danielle; Lee, Philip; Ronconi, Robert A
2009-01-01
This study evaluated the impact of small boat traffic on reaction distances of Marbled Murrelets (Brachyramphus marmoratus), in the marine waters of Pacific Rim National Park Reserve, British Columbia, Canada. Observers on moving boats recorded the minimum distance the boat came to murrelets on the water, and any disturbance reaction (fly, dive, no reaction). Out of the 7500 interactions 11.7% flew, 30.8% dove and 58.1% exhibited no flushing reaction. Using a product-limit analysis, we developed curves for the proportion of Marbled Murrelets flushing (dive or flight) as a function of reaction distance. Overall, the majority of Marbled Murrelets waited until boats were within 40 m before reacting, with 25% of the population reacting at 29.2m. A stepwise Cox regression indicated that age, boat speed, and boat density (loaded in that order), significantly affected flushing response. More juveniles flushed than adults (70.1 versus 51.7%), but at closer distances. Faster boats caused a greater proportion of birds to flush, and at further distances (25% of birds flushed at 40 m at speeds > 29 kph versus 28m at speeds <12kph). A stepwise logistic regression on diving and flight responses indicated that birds tended to fly completely out of feeding areas at the approach of boats travelling >28.8 kph and later in the season (July and August). Other secondary variables included; boat density and time of day. Discussion focused on possible management actions such as the application of speed limits, set back distances, and exclusion of boat traffic to protect Marbled Murrelets.
Vacuum Flushing of Sewer Solids
The vacuum sewer and tank cleaning (flushing) technology removes sewer solids from urban drainage systems, such as storage tanks and pipes. This technology is both effective and inexpensive. In addition, it can be considered a true green technology. It operates under atmospheri...
SEWER AND TANK SEDIMENT FLUSHING: CASE STUDIES
The objective of the report summarized here is to demonstrate that sewer system and storage tank flushing that reduces sediment deposition and accumulation is of prime importance to optimizing performance, maintaining structural integrity, and minimizing pollution of receiving wa...
REMEDIATION OF CONTAMINATED SOILS BY SOLVENT FLUSHING
Solvent flushing is a potential technique for remediating a waste disposal/spill site contaminated with organic chemicals. This technique involves the injection of a solvent mixture (e.g., water plus alcohols) that enhances contaminant solubility, reduces the retardation factor, ...
2011-01-01
Background This trial aims to evaluate the effectiveness of a group cognitive behavioural intervention to alleviate menopausal symptoms (hot flushes and night sweats) in women who have had breast cancer treatment. Hot flushes and night sweats are highly prevalent but challenging to treat in this population. Cognitive behaviour therapy has been found to reduce these symptoms in well women and results of an exploratory trial suggest that it might be effective for breast cancer patients. Two hypotheses are tested: Compared to usual care, group cognitive behavioural therapy will: 1. Significantly reduce the problem rating and frequency of hot flushes and nights sweats after six weeks of treatment and at six months post-randomisation. 2. Improve mood and quality of life after six weeks of treatment and at six months post-randomisation. Methods/Design Ninety-six women who have completed their main treatment for breast cancer and who have been experiencing problematic hot flushes and night sweats for over two months are recruited into the trial from oncology and breast clinics in South East London. They are randomised to either six weekly group cognitive behavioural therapy (Group CBT) sessions or to usual care. Group CBT includes information and discussion about hot flushes and night sweats in the context of breast cancer, monitoring and modifying precipitants, relaxation and paced respiration, stress management, cognitive therapy for unhelpful thoughts and beliefs, managing sleep and night sweats and maintaining changes. Prior to randomisation women attend a clinical interview, undergo 24-hour sternal skin conductance monitoring, and complete questionnaire measures of hot flushes and night sweats, mood, quality of life, hot flush beliefs and behaviours, optimism and somatic amplification. Post-treatment measures (sternal skin conductance and questionnaires) are collected six to eight weeks later and follow-up measures (questionnaires and a use of medical services measure) at six months post-randomisation. Discussion MENOS 1 is the first randomised controlled trial of cognitive behavioural therapy for hot flushes and night sweats that measures both self-reported and physiologically indexed symptoms. The results will inform future clinical practice by developing an evidence-based, non-medical treatment, which can be delivered by trained health professionals. Trial Registration Current Controlled Trials ISRCTN13771934 PMID:21281461
NASA Astrophysics Data System (ADS)
Torréton, Jean-Pascal; Rochelle-Newall, Emma; Jouon, Aymeric; Faure, Vincent; Jacquet, Séverine; Douillet, Pascal
2007-09-01
Hydrodynamic modeling can be used to spatially characterize water renewal rates in coastal ecosystems. Using a hydrodynamic model implemented over the semi-enclosed Southwest coral lagoon of New Caledonia, a recent study computed the flushing lag as the minimum time required for a particle coming from outside the lagoon (open ocean) to reach a specific station [Jouon, A., Douillet, P., Ouillon, S., Fraunié, P., 2006. Calculations of hydrodynamic time parameters in a semi-opened coastal zone using a 3D hydrodynamic model. Continental Shelf Research 26, 1395-1415]. Local e -flushing time was calculated as the time requested to reach a local grid mesh concentration of 1/e from the precedent step. Here we present an attempt to connect physical forcing to biogeochemical functioning of this coastal ecosystem. An array of stations, located in the lagoonal channel as well as in several bays under anthropogenic influence, was sampled during three cruises. We then tested the statistical relationships between the distribution of flushing indices and those of biological and chemical variables. Among the variables tested, silicate, chlorophyll a and bacterial biomass production present the highest correlations with flushing indices. Correlations are higher with local e-flushing times than with flushing lags or the sum of these two indices. In the bays, these variables often deviate from the relationships determined in the main lagoon channel. In the three bays receiving significant riverine inputs, silicate is well above the regression line, whereas data from the bay receiving almost insignificant freshwater inputs generally fit the lagoon channel regressions. Moreover, in the three bays receiving important urban and industrial effluents, chlorophyll a and bacterial production of biomass generally display values exceeding the lagoon channel regression trends whereas in the bay under moderate anthropogenic influence values follow the regressions obtained in the lagoon channel. The South West lagoon of New Caledonia can hence be viewed as a coastal mesotrophic ecosystem that is flushed by oligotrophic oceanic waters which subsequently replace the lagoonal waters with water considerably impoverished in resources for microbial growth. This flushing was high enough during the periods of study to influence the distribution of phytoplankton biomass, bacterial production of biomass and silicate concentrations in the lagoon channel as well as in some of the bay areas.
Vacuum Flushing of Sewer Solids (Slides)
The vacuum sewer and tank cleaning (flushing) technology removes sewer solids from urban drainage systems, such as storage tanks and pipes. This technology is both effective and inexpensive. In addition, it can be considered a true green technology. It operates under atmospheri...
DOT National Transportation Integrated Search
2007-02-01
This report summarizes the findings of research directed at identifying maintenance solutions for bleeding and : flushed asphalt pavements surfaced with seal coats or surface treatments. Although the basic mechanism associated with : both bleeding an...
BIOSURFACTANT-ENHANCED SOLUBILIZATION OF NAPL MIXTURES. (R827112)
Remediation of nonaqueous phase liquids (NAPLs) by conventional pump-and-treat methods (i.e., water flushing) is generally considered to be ineffective due to low water solubilities of NAPLs and to mass-transfer constraints. Chemical flushing techniques, such as surfactant flushi...
SURFACTANT FLUSH: HOW WELL DID IT WORK?
The Oklahoma Corporation Commission through a contract with Surbec-Art, Inc. of Norman Oklahoma has remediated TPH contamination at a gasoline spill at Golden, Oklahoma. Residual gasoline was removed from the subsurface using a flush of surfactant, followed by in situ bioremedia...
40 CFR 141.803 - Coliform sampling.
Code of Federal Regulations, 2012 CFR
2012-07-01
... aircraft water system, the sampling frequency must be determined by the disinfection and flushing frequency... disinfection and flushing frequency recommended by the aircraft water system manufacturer, when available. Where the aircraft water system manufacturer does not specify a recommended routine disinfection and...
FLUSHING FOR SEWER SEDIMENT, CORROSION, AND POLLUTION CONTROL
This presentation overviews causes of sewer deterioration and heavy pollutant discharges caused by rain events together with a discussion of their control methods. In particular, it covers in-sewer- and combined sewer overflow- (CSO-) storage-tank-flushing systems for removal of ...
NASA Technical Reports Server (NTRS)
Cohn, R. B. (Inventor)
1983-01-01
A mounting device for securing a microphone pick up head flush with respect to the external surfaces of the skin of an aircraft for detecting shock waves passing thereover is described. The mount includes a sleeve mounted internally of the aircraft for capturing and supporting an electronics package having the microphone pick up head attached thereto in a manner such that the head is flush with the external surface of the aircraft skin and a pressure seal is established between the internal and external surfaces of the aircraft skin.
Impact of the shape of the implantable ports on their efficiency of flow (injection and flushing)
Guiffant, Gérard; Flaud, Patrice; Durussel, Jean Jacques; Merckx, Jacques
2014-01-01
Now widely used, totally implantable venous access devices allow mid- and long-term, frequent, repeated, or continuous injection of therapeutic products by vascular, cavitary, or perineural access. The effective flushing of these devices is a key factor that ensures their long-lasting use. We present experimental results and a numerical simulation to demonstrate that the implementation of rounded edge wall cavities improves flushing efficiency. We use the same approaches to suggest that the deposit amount may be reduced by the use of rounded edge wall cavities. PMID:25258561
Flushing syndrome due to mahimahi (scombroid fish) poisoning.
Kim, R
1979-08-01
Scombroid fish poisoning, one of the most common adverse reactions to fish, is also probably one of the most common causes of a flushing syndrome. The reaction usually involves fishes of the Scombridae family but, in Hawaii, the reaction is most often due to mahimahi (Coryphaena hippurus). Onset of the reaction is usually abrupt and commonly associated with a prominent flush resembling a sunburn. Headache, tachye to a toxin with histamine-like properties, which is formed because improper refrigeration enables endogenous bacteria to decarboxylate histidine normally present in dark-meat fishes. Symptoms are usually promptly relieved by parenteral antihistamine therapy.
Use of Electronic Tablets for Patient Education on Flushing Peripherally Inserted Central Catheters.
Petroulias, Patricia L
The purpose of this study was to examine the efficacy of using an electronic tablet to provide patient education for flushing peripherally inserted central catheters (PICCs) as a way to reduce the incidence of occlusion. Eleven patients, newly diagnosed with cancer, participated in a pilot study that used a video on PICC flushing and remote coaching using FaceTime (Apple, Cupertino, CA) to teach patients how to maintain their PICCs in their homes. At the end of the 6-week intervention, no adverse outcomes (occlusions or infections) were noted among the patients who participated in the study.
Extended testing of compression distillation.
NASA Technical Reports Server (NTRS)
Bambenek, R. A.; Nuccio, P. P.
1972-01-01
During the past eight years, the NASA Manned Spacecraft Center has supported the development of an integrated water and waste management system which includes the compression distillation process for recovering useable water from urine, urinal flush water, humidity condensate, commode flush water, and concentrated wash water. This paper describes the design of the compression distillation unit, developed for this system, and the testing performed to demonstrate its reliability and performance. In addition, this paper summarizes the work performed on pretreatment and post-treatment processes, to assure the recovery of sterile potable water from urine and treated urinal flush water.
Space Shuttle reaction control system thruster metal nitrate removal and characterization
NASA Technical Reports Server (NTRS)
Saulsberry, R. L.; Mccartney, P. A.
1993-01-01
The Space Shuttle hypergolic primary reaction control system (PRCS) thrusters continue to fail-leak or fail-off at a rate of approximately 1.5 per flight, attributed primarily to metal nitrate formation in the nitrogen tetroxide (N2O4) pilot operated valves (POV's). The failures have continued despite ground support equipment (GSE) and subsystem operational improvements. As a result, the Johnson Space Center (JSC) White Sands Test Facility (WSTF) performed a study to characterize the contamination in the N204 valves. This study prompted the development and implementation of a highly successful flushing technique using deionized (DI) water and gaseous nitrogen (GN2) to remove the contamination while minimizing Teflon seat damage. Following flushing a comprehensive acceptance test is performed before the thruster is deemed recovered. Between the time WSTF was certified to process flight thrusters (March 1992) and September 1993, a 68 percent thruster recovery rate was achieved. The contamination flushed from these thrusters was analyzed and has provided insight into the corrosion process, which is reported in this publication. Additionally, the long-term performance of 24 flushed thrusters installed in the WSTF Fleet Leader Shuttle reaction control subsystem (RCS) test articles is being assessed. WSTF continues to flush flight and test article thrusters and compile data to investigate metal nitrate formation characteristics in leaking and nonleaking valves.
Bidegain, Maximiliano A; Cubitto, Maria Amelia; Curvetto, Nestor Raul
2015-01-01
Sunflower seed hulls were used as the main component of a solid substrate for the cultivation of the lingzhi or reishi medicinal mushroom Ganoderma lucidum. This study evaluated the effects of supplementing the substrate with olive oil and copper (II) on the mushroom production (MP) parameters and fruiting body total triterpenoid content. The addition of 1.5% olive oil increased total MP by 21.7% (dry basis) in 3 flushes. Copper (60 ppm) increased the daily productivity of the first flush (MP per day) by both reducing the time needed to harvest the crop and increasing the MP. However, the MP at the second and third flushes was reduced. When both supplements were combined, the MP at the first flush was 43% higher than with control treatment. No significant change in mushroom total triterpenoid content was observed by the addition of supplements to the substrate. An increase of 145-155% in the mushroom copper content was obtained by the addition of 60 ppm copper to the substrate. It is thus recommended to use substrate formulations containing both olive oil and copper (II) and harvest just the first flush.
Prevalence of hot flushes and night sweats around the world: a systematic review.
Freeman, E W; Sherif, K
2007-06-01
Many studies have evaluated the relationships between ethnicity and culture, prevalence of menopausal symptoms, and attitudes toward them, but few have assessed menopausal symptoms across cultures world-wide. This paper aims to systematically review the prevalence of hot flushes and night sweats, two prevalent symptoms of menopause, across the menopausal stages in different cultures and considers potential explanations for differences in prevalence rates. Sixty-six papers formed the basis for this review. Studies were organized by geographic region, and results are presented for North America, Europe, East Asia, Southeast Asia, Australia, Latin America, South Asia, Middle East, and Africa. Studies were included if they provided quantitative information on the occurrence of hot flushes. This report focuses on hot flushes and night sweats, the most common menopausal symptoms reported in epidemiologic studies. Studies reviewed indicate that vasomotor symptoms are highly prevalent in most societies. The prevalence of these symptoms varies widely and may be influenced by a range of factors, including climate, diet, lifestyle, women's roles, and attitudes regarding the end of reproductive life and aging. Patterns in hot flush prevalence were apparent for menopausal stages and, to a lesser degree, for regional variation. Caregivers should recognize that variations exist and ask patients specific questions about symptoms and their impact on usual functioning.
Ishigaki, Sayaka; Masui, Kenichi; Kazama, Tomiei
2016-03-01
Circulatory factors modify the onset time of neuromuscular-blocking drugs. Therefore, we hypothesized that infusion of a saline flush immediately after rocuronium administration would shorten the onset time without influencing the duration of the rocuronium effect. Forty-eight patients were randomly allocated to the control or saline flush group. Anesthesia was induced and maintained with propofol and remifentanil, and all patients received 0.6 mg/kg rocuronium in 10 mL of normal saline. In the saline flush group, 20 mL normal saline was immediately infused after rocuronium administration. Neuromuscular blockade was assessed using acceleromyography at the adductor pollicis muscle with train-of-four (TOF) stimulation. The neuromuscular indices for rocuronium were calculated as follows: the latent onset time, defined as the time from the start of rocuronium infusion until first occurrence of depression of the first twitch of the TOF (T1) ≥5%; onset time, defined as the time from the start of rocuronium infusion until first occurrence of depression of the T1 ≥95%; clinical duration, defined as the time from the start of rocuronium administration until T1 recovered to 25% of the final T1 value; recovery index, defined as the time for recovery of T1 from 25% to 75% of the final T1 value; and the total recovery time, defined as the time from the start of rocuronium administration until reaching a TOF ratio of 0.9. Significance was designated at P <0.05. The measured latent onset time and onset time were significantly shorter in the saline flush group than the control group by 15 seconds (95.2% confidence interval, 0-15, P = 0.007) and 15 seconds (0-30, P = 0.018), respectively. Saline flush significantly depressed the T1 height at 30, 45, and 60 seconds after the rocuronium bolus by 17%, 24%, and 14%, respectively. In addition, the recovery phase was significantly prolonged in the saline flush group. The mean clinical duration (5th-95th percentile range) in the saline flush group and control group was 35 minutes (27-63 minutes) and 31 minutes (19-48 minutes; P = 0.032), respectively; the recovery index was 13 minutes (8-25 minutes) and 10 minutes (7-19 minutes; P = 0.019), respectively; and the total recovery time was 61 minutes (44-108 minutes) and 50 minutes (35-93 minutes; P = 0.048), respectively. Administering a 20-mL saline flush immediately after infusion of 0.6 mg/kg rocuronium in 10 mL normal saline shortened the onset time and prolonged the recovery phase of neuromuscular blockade.
Water reuse at highway rest areas : evaluation phase.
DOT National Transportation Integrated Search
1977-01-01
The limited availability of water and stringent wastewater effluent standards at rest areas led to the development of a water recycle-reuse system to treat flush water from water closets. Flush fluid for rest area water closets accounts for 95% to 97...
Szabo, Jeffrey G; Muhammad, Nur; Heckman, Lee; Rice, Eugene W; Hall, John
2012-04-01
Germination was evaluated as an enhancement to decontamination methods for removing Bacillus spores from drinking water infrastructure. Germinating spores before chlorinating cement mortar or flushing corroded iron was more effective than chlorinating or flushing alone.
Improved diamond coring bits developed for dry and chip-flush drilling
NASA Technical Reports Server (NTRS)
Decker, W. E.; Hampe, W. R.; Hampton, W. H.; Simon, A. B.
1971-01-01
Two rotary diamond bit designs, one operating with a chip-flushing fluid, the second including auger section to remove drilled chips, enhance usefulness of tool for exploratory and industrial core-drilling of hard, abrasive mineral deposits and structural masonry.
FLUSHING FOR SEWER SEDIMENT, CORROSION, AND POLLUTION CONTROL
This paper overviews causes of combined-sewer deterioration and their heavy pollutant discharges caused by rain events together with a discussion of their control methods. In particular, it covers in-sewer and combined-sewer overflow (CSO) storage-tank-flushing systems for removi...
Application of landfill treatment approaches for stabilization of municipal solid waste.
Bolyard, Stephanie C; Reinhart, Debra R
2016-09-01
This research sought to compare the effectiveness of three landfill enhanced treatment approaches aimed at removing releasable carbon and nitrogen after anaerobic landfilling including flushing with clean water (FB 1), leachate recirculation with ex-situ treatment (FB 2), and leachate recirculation with ex-situ treatment and in-situ aeration (FB 3). After extensive treatment of the waste in the FB scenarios, the overall solids and biodegradable fraction were reduced relative to the mature anaerobically treated waste. In terms of the overall degradation, aeration did not provide any advantage over flushing and anaerobic treatment. Flushing was the most effective approach at removing biodegradable components (i.e. cellulose and hemicellulose). Leachate quality improved for all FBs but through different mechanisms. A significant reduction in ammonia-nitrogen occurred in FB 1 and 3 due to flushing and aeration, respectively. The reduction of chemical oxygen demand (COD) in FB 1 was primarily due to flushing. Conversely, the reduction in COD in FBs 2 and 3 was due to oxidation and precipitation during Fenton's Reagent treatment. A mass balance on carbon and nitrogen revealed that a significant fraction still remained in the waste despite the additional treatment provided. Carbon was primarily converted biologically to CH4 and CO2 in the FBs or removed during treatment using Fenton's Reagent. The nitrogen removal occurred through leaching or biological conversion. These results show that under extensive treatment the waste and leachate characteristics did meet published stability values. The minimum stability values achieved were through flushing although FB 2 and 3 were able to improve leachate quality and solid waste characteristics but not to the same extent as FB 1. Copyright © 2016 Elsevier Ltd. All rights reserved.
Haryanto, Bode; Chang, Chien-Hsiang
2015-01-01
In this study, the interfacial properties of biosurfactant rhamnolipid were investigated and were applied to remove adsorbed heavy metal ions from sand surfaces with flushing operations. The surface tension-lowering activity, micelle charge characteristic, and foaming ability of rhamnolipid were identified first. For rhamnolipid in water, the negatively charged characteristic of micelles or aggregates was confirmed and the foaming ability at concentrations higher than 40 mg/L was evaluated. By using the rhamnolipid solutions in a batch washing approach, the potential of applying the interfacial properties of rhamnolipid to remove adsorbed copper ions from sand surfaces was then demonstrated. In rhamnolipid solution flushing operations for sand-packed medium, higher efficiency was found for the removal of adsorbed copper ions with residual type than with inner-sphere interaction type, implying the important role of interaction type between the copper ion and the sand surface in the removal efficiency. In addition, the channeling effect of rhamnolipid solution flow in the sand-packed medium was clearly observed in the solution flushing operations and was responsible for the low removal efficiency with low contact areas between solution and sand. By using rhamnolipid solution with foam to flush the sand-packed medium, one could find that the channeling effect of the solution flow was reduced and became less pronounced with the increase in the rhamnolipid concentration, or with the enhanced foaming ability. With the reduced channeling effect in the flushing operations, the removal efficiency for adsorbed copper ions was significantly improved. The results suggested that the foam-enhanced rhamnolipid solution flushing operation was efficient in terms of surfactant usage and operation time.
Photosynthetic thermotolerance of woody savanna species in China is correlated with leaf life span
Zhang, Jiao-Lin; Poorter, L.; Hao, Guang-You; Cao, Kun-Fang
2012-01-01
Background and Aims Photosynthetic thermotolerance (PT) is important for plant survival in tropical and sub-tropical savannas. However, little is known about thermotolerance of tropical and sub-tropical wild plants and its association with leaf phenology and persistence. Longer-lived leaves of savanna plants may experience a higher risk of heat stress. Foliar Ca is related to cell integrity of leaves under stresses. In this study it is hypothesized that (1) species with leaf flushing in the hot-dry season have greater PT than those with leaf flushing in the rainy season; and (2) PT correlates positively with leaf life span, leaf mass per unit area (LMA) and foliar Ca concentration ([Ca]) across woody savanna species. Methods The temperature-dependent increase in minimum fluorescence was measured to assess PT, together with leaf dynamics, LMA and [Ca] for a total of 24 woody species differing in leaf flushing time in a valley-type savanna in south-west China. Key Results The PT of the woody savanna species with leaf flushing in the hot-dry season was greater than that of those with leaf flushing in the rainy season. Thermotolerance was positively associated with leaf life span and [Ca] for all species irrespective of the time of flushing. The associations of PT with leaf life span and [Ca] were evolutionarily correlated. Thermotolerance was, however, independent of LMA. Conclusions Chinese savanna woody species are adapted to hot-dry habitats. However, the current maximum leaf temperature during extreme heat stress (44·3 °C) is close to the critical temperature of photosystem II (45·2 °C); future global warming may increase the risk of heat damage to the photosynthetic apparatus of Chinese savanna species. PMID:22875810
Modulation of magmatic processes by carbon dioxide
NASA Astrophysics Data System (ADS)
Caricchi, L.; Sheldrake, T. E.; Blundy, J. D.
2017-12-01
Volatile solubility in magmas increases with pressure, although the solubility of CO2 is much lower than that of H2O. Consequently, magmas rising from depth release CO2-rich fluids, which inevitably interact with H2O-poor magmas in the upper crust (CO2-flushing). CO2-flushing triggers the exsolution of H2O-rich fluids, leading to an increase of volume and magma crystallisation. While the analyses of eruptive products demonstrates that this process operates in virtually all magmatic system, its impact on magmatic and volcanic processes has not been quantified. Here we show that depending on the initial magma crystallinity, and the depth of magma storage, CO2-flushing can lead to volcanic eruptions or promote conditions that favour the impulsive release of mineralising fluids. Our calculations show that the interaction between a few hundred ppm of carbonic fluids, and crystal-poor magmas stored at shallow depths, produces rapid pressurisation that can potentially lead to an eruption. Further addition of CO2 increases magma compressibility and crystallinity, reducing the potential for volcanic activity, promoting the formation of ore deposits. Increasing the depth of fluid-magma interaction dampens the impact of CO2-flushing on the pressurisation of a magma reservoir. CO2-flushing may result in surface inflation and increases in surface CO2 fluxes, which are commonly considered signs of an impending eruption, but may not necessarily result in eruption depending on the initial crystallnity and depth of the magmatic reservoir. We propose that CO2-flushing is a powerful agent modulating the pressurisation of magma reservoirs and the release of mineralising fluids from upper crustal magma reservoirs.
Microbial contamination of dental unit waterlines: short- and long-term effects of flushing.
Santiago, J I; Huntington, M K; Johnston, A M; Quinn, R S; Williams, J F
1994-01-01
The extensive microbial contamination of DUW in this study is consistent with that described in previous reports. Comparisons with other common public potable water sources emphasize the relatively high concentrations of microorganisms in DUW, and the low numbers of bacteria in most domestic water samples. Microscopic evidence of amebas and worms in DUW reinforces the need for further qualitative and quantitative studies of these contaminants of dental tubing biofilm. In most cases, flushing for two minutes reduced microbial concentrations in DUW. However, in a few cases, concentrations rose; in others, the reductions were negligible. Moreover, after 30 minutes of stasis, or use of the waterline in a routine dental procedure, microbial counts were frequently restored to preflush levels or higher. The longer-term ineffectiveness 30 minutes after flushing is understandable when the hydrodynamics of laminar flow of water in narrow-bore tubing are considered. Biofilm on the tubing wall remains intact during flushes and quickly generates more bacteria during stasis. Increased bacterial concentrations after flushing probably result from sloughing of biofilm from the tubing wall because of stretching and movement of the line during routine use. These two phenomena undermine the benefits of routine water flushes. It is a common belief that bacterial levels build to extremes during overnight or weekend stasis; we observed more variation in contamination levels during the workday than between overnight stasis and typical workday samples. The presence of hemolytic staphylococci and streptococci in water samples from lines that were supplied only from sterile water reservoirs adds to the growing evidence that part of the microbial flora in DUWLs may be derived from patients' mouths. Additional prophylactic measures to limit bacterial contamination in DUW should be implemented according to standard principles used in other medical fluid delivery devices.
Mechanical characteristics of plastic base Ports and impact on flushing efficacy.
Guiffant, Gérard; Flaud, Patrice; Royon, Laurent; Burnet, Espérie; Merckx, Jacques
2017-01-01
Three types of totally implantable venous access devices, Ports, are currently in use: titanium, plastic (polyoxymethylene, POM), and mixed (titanium base with a POM shell). Physics theory suggests that the interaction between a non-coring needle (NCN, made of stainless steel) and a plastic base would lead to the stronger material (steel) altering the more malleable material (plastic). To investigate whether needle impacts can alter a plastic base's surface, thus potentially reducing flushing efficacy. A Port made of POM was punctured 200 times with a 19-gauge NCN. Following the existing guidelines, the needle tip pricked the base with each puncture. The Port's base was then examined using a two-dimensional optical instrument, and a bi-dimensional numerical simulation using COMSOL ® was performed to investigate potential surface irregularities and their impact on fluid flow. Each needle impact created a hole (mean depth, 0.12 mm) with a small bump beside it (mean height, 0.02 mm) the Reynolds number Re k ≈10. A numerical simulation of the one hole/bump set showed that the flushing efficacy was 60% that of flushing along a flat surface. In clinical practice, the number of times a Port is punctured depends on patient and treatment characteristics, but each needle impact on the plastic base may increase the risk of decreased flushing effectiveness. Therefore, the more a plastic Port is accessed, the greater the risk of microorganisms, blood products, and medication accumulation. Multiple needle impacts created an irregular surface on the Port's base, which decreased flushing efficacy. Clinical investigation is needed to determine whether plastic base Ports are associated with an increased risk of Port infection and occlusion compared to titanium base Ports.
DOT National Transportation Integrated Search
2009-06-01
The primary objective of this study was to design and test a first flush-based stormwater treatment device for elevated linear transportation projects/roadways that is capable of complying with MS4 regulations. The innovative idea behind the device i...
21 CFR 225.65 - Equipment cleanout procedures.
Code of Federal Regulations, 2010 CFR
2010-04-01
...) DRUGS: GENERAL CURRENT GOOD MANUFACTURING PRACTICE FOR MEDICATED FEEDS Product Quality Control § 225.65 Equipment cleanout procedures. (a) Adequate cleanout procedures for all equipment used in the manufacture... sequential production of feeds. (2) If flushing is utilized, the flush material shall be properly identified...
46 CFR 194.15-11 - Flushing systems.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 7 2010-10-01 2010-10-01 false Flushing systems. 194.15-11 Section 194.15-11 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OCEANOGRAPHIC RESEARCH VESSELS HANDLING, USE, AND CONTROL OF EXPLOSIVES AND OTHER HAZARDOUS MATERIALS Chemistry Laboratory and Scientific Laboratory...
40 CFR 141.804 - Aircraft water system operations and maintenance plan.
Code of Federal Regulations, 2010 CFR
2010-07-01
...) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS Aircraft Drinking Water Rule... must include the following requirements for procedures for disinfection and flushing of aircraft water system. (i) The air carrier must conduct disinfection and flushing of the aircraft water system in...
In situ flushing groundwater remediation technologies, such as cosolvent flushing, rely on the stability of the interface between the resident and displacing fluids for efficient removal of contaminants. Contrasts in density and viscosity between the resident and displacing flui...
46 CFR 194.15-11 - Flushing systems.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 7 2013-10-01 2013-10-01 false Flushing systems. 194.15-11 Section 194.15-11 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OCEANOGRAPHIC RESEARCH VESSELS HANDLING, USE, AND CONTROL OF EXPLOSIVES AND OTHER HAZARDOUS MATERIALS Chemistry Laboratory and Scientific Laboratory...
SEWER AND TANK FLUSHING FOR CORROSION AND POLLUTION CONTROL
This paper presents an overview of the causes of sewer deterioration and control methods that can prevent or arrest this deterioration. articular, the paper addresses the use of inline- and combined sewer overflow (CSO) storage tank-flushing systems for removing sediments and mi...
Muhammad, Nur; Heckman, Lee; Rice, Eugene W.; Hall, John
2012-01-01
Germination was evaluated as an enhancement to decontamination methods for removing Bacillus spores from drinking water infrastructure. Germinating spores before chlorinating cement mortar or flushing corroded iron was more effective than chlorinating or flushing alone. PMID:22267659
SEWER AND TANK FLUSHING FOR SEDIMENT, CORROSION AND POLLUTION CONTROL
This paper presents an overview of causes of sewer deterioration together with a discussion of control methods that can prevent or arrest this deterioration. In particular, the paper covers inline- and combined sewer overflow- (CSO) storage-tank-flushing systems for removal of se...
Maboreke, Hazel R; Feldhahn, Lasse; Bönn, Markus; Tarkka, Mika T; Buscot, Francois; Herrmann, Sylvie; Menzel, Ralph; Ruess, Liliane
2016-08-12
Pedunculate oak (Quercus robur L.), an important forest tree in temperate ecosystems, displays an endogenous rhythmic growth pattern, characterized by alternating shoot and root growth flushes paralleled by oscillations in carbon allocation to below- and aboveground tissues. However, these common plant traits so far have largely been neglected as a determining factor for the outcome of plant biotic interactions. This study investigates the response of oak to migratory root-parasitic nematodes in relation to rhythmic growth, and how this plant-nematode interaction is modulated by an ectomycorrhizal symbiont. Oaks roots were inoculated with the nematode Pratylenchus penetrans solely and in combination with the fungus Piloderma croceum, and the systemic impact on oak plants was assessed by RNA transcriptomic profiles in leaves. The response of oaks to the plant-parasitic nematode was strongest during shoot flush, with a 16-fold increase in the number of differentially expressed genes as compared to root flush. Multi-layered defence mechanisms were induced at shoot flush, comprising upregulation of reactive oxygen species formation, hormone signalling (e.g. jasmonic acid synthesis), and proteins involved in the shikimate pathway. In contrast during root flush production of glycerolipids involved in signalling cascades was repressed, suggesting that P. penetrans actively suppressed host defence. With the presence of the mycorrhizal symbiont, the gene expression pattern was vice versa with a distinctly stronger effect of P. penetrans at root flush, including attenuated defence, cell and carbon metabolism, likely a response to the enhanced carbon sink strength in roots induced by the presence of both, nematode and fungus. Meanwhile at shoot flush, when nutrients are retained in aboveground tissue, oak defence reactions, such as altered photosynthesis and sugar pathways, diminished. The results highlight that gene response patterns of plants to biotic interactions, both negative (i.e. plant-parasitic nematodes) and beneficial (i.e. mycorrhiza), are largely modulated by endogenous rhythmic growth, and that such plant traits should be considered as an important driver of these relationships in future studies.
Contrasts in Flushing Patterns Among Solutes
NASA Astrophysics Data System (ADS)
Shanley, J. B.; Sebestyen, S. D.; Boyer, E. W.; Ross, D. S.
2005-12-01
High-frequency sampling since 1991 at the 41-ha forested W-9 catchment at Sleepers River, Vermont provides a wealth of data to evaluate catchment flushing responses. Snowmelt and rain-on-snow account for about half the annual flow at Sleepers River during a 6-week period in early spring. Summer and fall storms produce frequent high-flows of short duration. Flushing of weathering products (Ca, Mg, Na, K, SO4 ANC, Si) is generally supply-limited, and is masked by rapid dilution with meteoric and soil water during events. In contrast, flushing dominates the stream dynamics of atmospheric and pedogenic solutes (NO3, DOC, Hg), causing concentration increases with increasing flow. During snowmelt, NO3 peaks well before the peak in discharge, whereas DOC tracks discharge closely and peaks concurrently. These patterns suggest that NO3 is supply-limited and DOC is transport-limited; W-9 is not N saturated and the available NO3 supply is readily leached from the soil, whereas stream DOC progressively increases as rising water tables and expanding saturated areas connect with new source areas. In summer storms, DOC and NO3 both peak simultaneously with discharge. Unlike DOC, however, NO3 concentrations are attenuated with subsequent storms that follow within a few days, consistent with a depletion of the NO3 pool available for flushing as observed during snowmelt. Sleepers River contrasts with the Snake River in Colorado, where NO3 and DOC reverse roles; DOC peaks early in snowmelt and may be supply-limited due to the paucity of organic matter. An ample supply of NO3 is available due to N saturation and N fixation, but NO3 may be transport-limited due to primary N sources in talus deposits far from the stream. Hg is an atmospheric solute that accumulates in soils because of its affinity for organic matter, and is flushed by high flows, mostly in association with suspended sediment. The concept of flushing provides a useful context for understanding the variable responses of solutes to the expansion of catchment saturation during high flow events.
Guiffant, Gérard; Durussel, Jean Jacques; Flaud, Patrice; Vigier, Jean Pierre; Merckx, Jacques
2012-01-01
The use of totally implantable venous access devices developed as a medical device allowing mid- and long-term, frequent, repeated, or continuous injection of therapeutic products, by vascular, cavitary, or perineural access. The effective flushing of these devices is a central element to assure long-lasting use. Our experimental work demonstrates that directing the Huber point needle opening in the diametrically opposite direction of the implantable port exit channel increases the flushing efficiency. These results are consolidated by numerical computations, which support recommendations not only for their maintenance, but also for their use.
Guiffant, Gérard; Durussel, Jean Jacques; Flaud, Patrice; Vigier, Jean Pierre; Merckx, Jacques
2012-01-01
The use of totally implantable venous access devices developed as a medical device allowing mid- and long-term, frequent, repeated, or continuous injection of therapeutic products, by vascular, cavitary, or perineural access. The effective flushing of these devices is a central element to assure long-lasting use. Our experimental work demonstrates that directing the Huber point needle opening in the diametrically opposite direction of the implantable port exit channel increases the flushing efficiency. These results are consolidated by numerical computations, which support recommendations not only for their maintenance, but also for their use. PMID:23166455
Odor control in swine buildings: recycle flush vs. automated scraper
USDA-ARS?s Scientific Manuscript database
A research project was conducted to compare odor concentrations in exhaust of traditional flush barns and barns equipped with automated scrapers. The study was conducted at commercial tunnel-ventilated swine barns in northwest Missouri. Odor samples were collected from the barn exhaust in polyvinyl ...
32. INTERIOR OF STORM PORCH ADDITION SHOWING FLUSH SIDEEXIT DOOR ...
32. INTERIOR OF STORM PORCH ADDITION SHOWING FLUSH SIDEEXIT DOOR AT PHOTO LEFT CENTER AND 1-LIGHT OVER 1LIGHT SASH WINDOW THROUGH WEST WALL AT PHOTO RIGHT. VIEW TO SOUTH. - Rush Creek Hydroelectric System, Clubhouse Cottage, Rush Creek, June Lake, Mono County, CA
APPENDIX C - ADDITIONAL INFORMATION ON FLUSHING IN ESTUARIES
Water residence time is an important determinant of the sensitivity of the response of estuaries and other water bodies to nutrient loading. A variety of terms such as residence time, flushing time, transit time, turnover time, and age are used to describe time scales for transpo...
CONTROLLED RELEASE, BLIND TEST OF DNAPL REMEDIATION BY ETHANOL FLUSHING
A dense nonaqueous phase liquid (DNAPL) source zone was established within a sheet-pile
isolated cell through a controlled release of perchloroethylene (PCE) to evaluate DNAPL
remediation by in-situ cosolvent flushing. Ethanol was used as the cosolvent, and the main remedia...
Ferraro, Alberto; Fabbricino, Massimiliano; La Marca, Agostino; Panico, Antonio; Spasiano, Danilo; Tognacchini, Alice; Pirozzi, Francesco
2018-01-01
This paper presents the results of an experimental study aimed at investigating the effect of operative parameters on the efficiency of a soil flushing process, conducted on real contaminated soil containing high amounts of Cu and Zn. Soil flushing tests were carried out with Ethylenediamine-N,N′-disuccinic acid (EDDS) as a flushing agent due to its high biodegradability and environmentally friendly characteristics. Process parameters such as Empty-Bed Contact Time (EBCT) and EDDS solution molarity were varied from 21–33 h and from 0.36–3.6 mM, respectively. Effects on the mobility of cations such as Fe and Mn were also investigated. Results showed that very high performances can be obtained at [EDDS] = 3.6 mM and EBCT = 33 h. In these conditions, in fact, the amount of removed Cu was 53%, and the amount of removed Zn was 46%. Metal distribution at different depths from the top surface revealed that Cu has higher mobility than Zn. The process results were strongly dependent on the exchange of metals due to the different stability constants of the EDDS complexes. Finally, results from a comparative study showed that soil washing treatment reached the same removal efficiency of the flushing process in a shorter time but required a larger amount of the EDDS solution. PMID:29562649
Race, Marco; Ferraro, Alberto; Fabbricino, Massimiliano; La Marca, Agostino; Panico, Antonio; Spasiano, Danilo; Tognacchini, Alice; Pirozzi, Francesco
2018-03-18
This paper presents the results of an experimental study aimed at investigating the effect of operative parameters on the efficiency of a soil flushing process, conducted on real contaminated soil containing high amounts of Cu and Zn. Soil flushing tests were carried out with Ethylenediamine- N , N '-disuccinic acid (EDDS) as a flushing agent due to its high biodegradability and environmentally friendly characteristics. Process parameters such as Empty-Bed Contact Time (EBCT) and EDDS solution molarity were varied from 21-33 h and from 0.36-3.6 mM, respectively. Effects on the mobility of cations such as Fe and Mn were also investigated. Results showed that very high performances can be obtained at [EDDS] = 3.6 mM and EBCT = 33 h. In these conditions, in fact, the amount of removed Cu was 53%, and the amount of removed Zn was 46%. Metal distribution at different depths from the top surface revealed that Cu has higher mobility than Zn. The process results were strongly dependent on the exchange of metals due to the different stability constants of the EDDS complexes. Finally, results from a comparative study showed that soil washing treatment reached the same removal efficiency of the flushing process in a shorter time but required a larger amount of the EDDS solution.
NASA Astrophysics Data System (ADS)
Agaoglu, Berken; Scheytt, Traugott; Copty, Nadim K.
2012-10-01
This study examines the mechanistic processes governing multiphase flow of a water-cosolvent-NAPL system in saturated porous media. Laboratory batch and column flushing experiments were conducted to determine the equilibrium properties of pure NAPL and synthetically prepared NAPL mixtures as well as NAPL recovery mechanisms for different water-ethanol contents. The effect of contact time was investigated by considering different steady and intermittent flow velocities. A modified version of multiphase flow simulator (UTCHEM) was used to compare the multiphase model simulations with the column experiment results. The effect of employing different grid geometries (1D, 2D, 3D), heterogeneity and different initial NAPL saturation configurations was also examined in the model. It is shown that the change in velocity affects the mass transfer rate between phases as well as the ultimate NAPL recovery percentage. The experiments with low flow rate flushing of pure NAPL and the 3D UTCHEM simulations gave similar effluent concentrations and NAPL cumulative recoveries. Model simulations over-estimated NAPL recovery for high specific discharges and rate-limited mass transfer, suggesting a constant mass transfer coefficient for the entire flushing experiment may not be valid. When multi-component NAPLs are present, the dissolution rate of individual organic compounds (namely, toluene and benzene) into the ethanol-water flushing solution is found not to correlate with their equilibrium solubility values.
FIELD-SCALE EVALUATION OF IN SITU COSOLVENT FLUSHING FOR ENCHANCED AQUIFER REMEDIATION
A comprehensive, field-scale evaluation of in situ cosolvent flushing for enhanced remediation of nonaqueous phase liquid (NAPL)-contaminated aquifers was performed in a hydraulically isolated test cell (about 4.3 m x 3.6 m) constructed at a field site at Hill Air Force Base, Uta...
30 CFR 71.401 - Location of facilities.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Bathing Facilities, Change Rooms, and Sanitary Flush Toilet Facilities at Surface Coal Mines § 71.401 Location of facilities. Bathhouses, change rooms, and sanitary flush toilet facilities shall be in a... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Location of facilities. 71.401 Section 71.401...
30 CFR 71.401 - Location of facilities.
Code of Federal Regulations, 2012 CFR
2012-07-01
... Bathing Facilities, Change Rooms, and Sanitary Flush Toilet Facilities at Surface Coal Mines § 71.401 Location of facilities. Bathhouses, change rooms, and sanitary flush toilet facilities shall be in a... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Location of facilities. 71.401 Section 71.401...
30 CFR 71.401 - Location of facilities.
Code of Federal Regulations, 2014 CFR
2014-07-01
... Bathing Facilities, Change Rooms, and Sanitary Flush Toilet Facilities at Surface Coal Mines § 71.401 Location of facilities. Bathhouses, change rooms, and sanitary flush toilet facilities shall be in a... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Location of facilities. 71.401 Section 71.401...
30 CFR 71.401 - Location of facilities.
Code of Federal Regulations, 2013 CFR
2013-07-01
... Bathing Facilities, Change Rooms, and Sanitary Flush Toilet Facilities at Surface Coal Mines § 71.401 Location of facilities. Bathhouses, change rooms, and sanitary flush toilet facilities shall be in a... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Location of facilities. 71.401 Section 71.401...
The Role of Flushing Dental Waterlines for the Removal of Microbial Contaminants - MCEARD
Objectives. This study was designed to determine the role of flushing dental water lines for the removal of heterotrophic plate count bacteria, Legionella spp., and free-living protozoa. Methods. Forty dental offices were surveyed in the study. An initial sample and a sample tak...
HYDRAULIC CHARACTERISTICS OF SEWER SEDIMENT GATE FLUSHING TANKS: LABORATORY FLUME STUDIES
The objective of this study was to test the performance of gate flushing tanks, simulated in a laboratory flume, to remove sediments from combined sewers and storage tanks. A significant amount of sediment/debris/sludge may accumulate at the bottom of a sewer during dry weather o...
HYDRAULIC CHARACTERISTICS OF SEWER SEDIMENT GATE-FLUSHING TANKS: LABORATORY FLUME STUDIES
The objective of this study was to test the performance of gate-flushing tanks, simulated in a laboratory flume, to remove sediments from combined sewers and storage tanks. A significant amount of sediment/debris/sludge may accumulate at the bottom of a sewer during dry weather o...
A network of multilevel samplers was used to evaluate the spatial patterns in containment extraction during an in situ cosolvent flushing field test. The study was conducted in an isolation test cell installed in a fuel contaminated site at Hill Air Force Base, Utah. Partitioni...
Concealed hinge permits flush mounting of doors and hatches
NASA Technical Reports Server (NTRS)
Holman, E. V.
1966-01-01
Hinge assembly permits flush mounting of doors and hatches of considerable thickness so that the axis of instant rotation, produced by the hinge, lies outside the panel surface and beyond the perimeter adjacent to the hinge. In operation, motion of the assembly is initially parallel, changing to angular after clearing the panel perimeter.
Behavior Interventions in the Restroom: Flushing Away Noise
ERIC Educational Resources Information Center
Pasqua, Jamie L.; Dart, Evan H.; Radley, Keith C.
2016-01-01
This study investigated the effectiveness of Flushing Away Noise, an interdependent group contingency using an iPod equipped with a decibel meter application, for reducing noise in restrooms. Two Head Start classrooms in the Southeastern United States, referred for demonstrating high levels of student noise in the restroom, were included in the…
30 CFR 71.400 - Bathing facilities; change rooms; sanitary flush toilet facilities.
Code of Federal Regulations, 2010 CFR
2010-07-01
... flush toilet facilities. 71.400 Section 71.400 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY HEALTH STANDARDS-SURFACE COAL MINES AND SURFACE... installations and at the surface worksites of such mine. (Note: Sanitary facilities at surface work areas of...
77 FR 76039 - Formations of, Acquisitions by, and Mergers of Bank Holding Companies
Federal Register 2010, 2011, 2012, 2013, 2014
2012-12-26
... York, with and into Flushing Commercial Bank, North New Hyde Park, New York, which will become a New York State-chartered commercial bank and change its name to Flushing Bank. Comments on this proposal... FEDERAL RESERVE SYSTEM Formations of, Acquisitions by, and Mergers of Bank Holding Companies The...
The Total-Pressure Recovery and Drag Characteristics of Several Auxiliary Inlets at Transonic Speeds
NASA Technical Reports Server (NTRS)
Dennard, John S.
1959-01-01
Several flush and scoop-type auxiliary inlets have been tested for a range of Mach numbers from 0.55 to 1.3 to determine their transonic total-pressure recovery and drag characteristics. The inlet dimensions were comparable with the thickness of the boundary layer in which they were tested. Results indicate that flush inlets should be inclined at very shallow angles with respect to the surface for optimum total-pressure recovery and drag characteristics. Deep, narrow inlets have lower drag than wide shallow ones at Mach numbers greater than 0.9 but at lower Mach numbers the wider inlets proved superior. Inlets with a shallow approach ramp, 7 deg, and diverging ramp walls which incorporated boundary-layer bypass had lower drag than any other inlet tested for Mach numbers up to 1.2 and had the highest pressure recovery of all of the flush inlets. The scoop inlets, which operated in a higher velocity flow than the flush inlets, had higher drag coefficients. Several of these auxiliary inlets projected multiple, periodic shock waves into the stream when they were operated at low mass-flow ratios.
Modeling of highway stormwater runoff.
Kim, Lee-Hyung; Kayhanian, Masoud; Zoh, Kyung-Duk; Stenstrom, Michael K
2005-09-15
Highways are stormwater intensive landuses since they are impervious and have high pollutant mass emissions from vehicular activity. Vehicle emissions include different pollutants such as heavy metals, oil and grease, particulates from sources such as fuels, brake pad wear and tire wear, and litter. To understand the magnitude and nature of the stormwater emissions, a 3-year study was conducted to quantify stormwater pollutant concentrations, mass emission rates, and the first flush of pollutants. Eight highway sites were monitored over 3 years for a large suite of pollutants. The monitoring protocol emphasized detecting the first flush and quantifying the event mean concentration. Grab and flow-weighted composite samples, rainfall, and runoff data were collected. A new runoff model with four parameters was developed that to describe the first flush of pollutants for a variety of rainfall and runoff conditions. The model was applied to more than 40 events for 8 pollutants, and the parameters were correlated to storm and site conditions, such as total runoff, antecedent dry days, and runoff coefficient. Improved definitions of first flush criteria are also presented.
NASA Astrophysics Data System (ADS)
Kuang, A. Q.; Brunner, D.; LaBombard, B.; Leccacorvi, R.; Vieira, R.
2018-04-01
An array of flush-mounted and toroidally elongated Langmuir probes (henceforth called rail probes) have been specifically designed for the Alcator C-Mod's vertical target plate divertor and operated over multiple campaigns. The "flush" geometry enables the tungsten electrodes to survive high heat flux conditions in which traditional "proud" tungsten electrodes suffer damage from melting. The toroidally elongated rail-like geometry reduces the influence of sheath expansion, which is an important effect to consider in the design and interpretation of flush-mounted Langmuir probes. The new rail probes successfully operated during C-Mod's FY2015 and FY2016 experimental campaigns with no evidence of damage, despite being regularly subjected to heat flux densities parallel to the magnetic field exceeding ˜1 GW m-2 for short periods of time. A comparison between rail and proud probe data indicates that sheath expansion effects were successfully mitigated by the rail design, extending the use of these Langmuir probes to incident magnetic field line angles as low as 0.5°.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hudson, W.G.
Scapteriscus vicinus is the most important pest of turf and pasture grasses in Florida. This study develops a method of correlating sample results with true population density and provides the first quantitative information on spatial distribution and movement patterns of mole crickets. Three basic techniques for sampling mole crickets were compared: soil flushes, soil corer, and pitfall trapping. No statistical difference was found between the soil corer and soil flushing. Soil flushing was shown to be more sensitive to changes in population density than pitfall trapping. No technique was effective for sampling adults. Regression analysis provided a means of adjustingmore » for the effects of soil moisture and showed soil temperature to be unimportant in predicting efficiency of flush sampling. Cesium-137 was used to label females for subsequent location underground. Comparison of mean distance to nearest neighbor with the distance predicted by a random distribution model showed that the observed distance in the spring was significantly greater than hypothesized (Student's T-test, p < 0.05). Fall adult nearest neighbor distance was not different than predicted by the random distribution hypothesis.« less
Costello, Terry; Watkins, Linda; Straign, Mike; Bean, William; Toth, Linda; Rehg, Jerold
1998-03-01
An important responsibility of animal care programs is to protect research animals from exposure to potentially pathogenic microorganisms. To validate the need for steam sterilization of rodent automatic watering racks, we evaluate the post-sanitation microbial contamination of experimentally inoculated racks and of racks that had been used to house conventional mice. We tested three sanitation protocols: rack-washer sanitation without manifold flush, sanitation that included manifold flush, and sanitation that included manifold flush followed by autoclaving. Rack sanitation, with or without manifold flush, did not reliably eliminate microbial flora from the lixits or manifold drainage water. A total of 43% of all non-autoclaved racks were positive for bacterial contamination after sanitation, and racks that had been used for conventional animal housing were more frequently positive than were experimentally inoculated racks (79% vs 18%). These data indicate that steam sterilization is necessary for eliminating bacteria from automatic watering systems. These observations are particularly important in light of increasing numbers of immune-impaired rodents that may be inadvertently and unnecessarily exposed to microbial pathogens via the automatic watering system.
Reynoso, Mercedes M.N.; Seccacini, Emilia A.; Calcagno, Javier A.; Zerba, Eduardo N.
2017-01-01
DEET and IR3535 are insect repellents present worldwide in commercial products; their efficacy has been mainly evaluated in mosquitoes. This study compares the toxicological effects and the behavioral responses induced by both repellents on the blood-sucking bug Triatoma infestans Klug (Hemiptera: Reduviidae), one of the main vectors of Chagas disease. When applied topically, the Median Lethal Dose (72 h) for DEET was 220.8 µg/insect. Using IR3535, topical application of 500 µg/insect killed no nymphs. The minimum concentration that produced repellency was the same for both compounds: 1,15 µg/cm2. The effect of a mixture DEET:IR3535 1:1 was similar to that of their pure components. Flushing out was assessed in a chamber with a shelter containing groups of ten nymphs. The repellents were aerosolized on the shelter and the number of insects leaving it was recorded for 60 min. During that time, 0.006 g/m3 of the positive control tetramethrin flushed out 76.7% of the nymphs, while 1.76 g/m3 of DEET or IR3535 flushed out 30 and 0%, respectively. The concentrations required for both compounds to produce toxicity or flushing out are too high to have any practical applications. However, they showed a promising repellency. Additional research should be done to evaluate their possible use for personal protection against T. infestans bites. PMID:28533956
Saxton, Ronald E; Yeasmin, Farzana; Alam, Mahbub-Ul; Al-Masud, Abdullah; Dutta, Notan Chandra; Yeasmin, Dalia; Luby, Stephen P; Unicomb, Leanne; Winch, Peter J
2017-09-01
Provision of toilets is necessary but not sufficient to impact health as poor maintenance may impair toilet function and discourage their consistent use. Water in urban slums is both scarce and a prerequisite for toilet maintenance behaviours. We describe the development of behaviour change communications and selection of low-cost water storage hardware to facilitate adequate flushing among users of shared toilets. We conducted nine focus group discussions and six ranking exercises with adult users of shared toilets (50 females, 35 males), then designed and implemented three pilot interventions to facilitate regular flushing and improve hygienic conditions of shared toilets. We conducted follow-up assessments 1 and 2 months post-pilot including nine in-depth interviews and three focus group discussions with adult residents (23 females, 15 males) and three landlords in the pilot communities. Periodic water scarcity was common in the study communities. Residents felt embarrassed to carry water for flushing. Reserving water adjacent to the shared toilet enabled slum residents to flush regularly. Signs depicting rules for toilet use empowered residents and landlords to communicate these expectations for flushing to transient tenants. Residents in the pilot reported improvements in cleanliness and reduced odour inside toilet cubicles. Our pilot demonstrates the potential efficacy of low-cost water storage and behaviour change communications to improve maintenance of and user satisfaction with shared toilets in urban slum settings. © 2017 John Wiley & Sons Ltd.
Production flush of Agaricus blazei on Brazilian casing layers
Colauto, Nelson Barros; da Silveira, Adriano Reis; da Eira, Augusto Ferreira; Linde, Giani Andrea
2011-01-01
This study aimed to verify the biological efficiency and production flushes of Agaricus blazei strains on different casing layers during 90 cultivation days. Four casing layers were used: mixture of subsoil and charcoal (VCS), lime schist (LSC), São Paulo peat (SPP) and Santa Catarina peat (SCP); and two genetically distant A. blazei strains. The fungus was grown in composted substratum and, after total colonization, a pasteurized casing layer was added over the substratum, and fructification was induced. Mushrooms were picked up daily when the basidiocarp veil was stretched, but before the lamella were exposed. The biological efficiency (BE) was determined by the fresh basidiocarp mass divided by the substratum dry mass, expressed in percentage. The production flushes were also determined over time production. The BE and production flushes during 90 days were affected by the strains as well as by the casing layers. The ABL26 and LSC produced the best BE of 60.4%. Although VCS is the most used casing layer in Brazil, it is inferior to other casing layers, for all strains, throughout cultivation time. The strain, not the casing layer, is responsible for eventual variations of the average mushroom mass. In average, circa 50% of the mushroom production occurs around the first month, 30% in the second month, and 20% in third month. The casing layer water management depends on the casing layer type and the strain. Production flush responds better to water reposition, mainly with ABL26, and better porosity to LSC and SCP casing layers. PMID:24031673
Albadrani, Ahmed
2017-01-17
While primary hyperhidrosis can be seen in men, accompanying hot flushes is rarely seen in men. Primary hyperhidrosis is thought to be related to overactivity of the sympathetic nervous system while hot flushes are believed to be related to altered peripheral vascular reactivity and a narrowed thermoregulatory zone. I report the case of a 29-year-old man of Arab origin who presented to a dermatology clinic with a complaint of generalized sweating, with heavier involvement of his inguinal region, axilla, and lower back. His complaint was associated with a transient hot sensation and erythema over the affected areas. He did not respond to topical antiperspirants containing aluminum chloride, topical aluminum chloride, or to botulinum toxin A injected in both inguinal areas. He was then referred to an endocrinology clinic to rule out secondary causes of hyperhidrosis and hot flushes; a primary diagnosis was confirmed. He did not respond to oral glycopyrrolate and additionally was complaining of its anticholinergic side effects. The glycopyrrolate was then replaced with oral clonidine 0.15 mg twice a day. Clonidine was well tolerated without remarkable side effects and he quickly started to feel marked improvement which was maintained for 2 years. I report an atypical presentation of primary hyperhidrosis and hot flushes that was effectively controlled by clonidine without remarkable side effects. Further research on a large number of patients may be required before recommending clonidine in similar conditions.
Defne, Zafer; Ganju, Neil K.
2015-01-01
Estuarine residence time is a major driver of eutrophication and water quality. Barnegat Bay-Little Egg Harbor (BB-LEH), New Jersey, is a lagoonal back-barrier estuary that is subject to anthropogenic pressures including nutrient loading, eutrophication, and subsequent declines in water quality. A combination of hydrodynamic and particle tracking modeling was used to identify the mechanisms controlling flushing, residence time, and spatial variability of particle retention. The models demonstrated a pronounced northward subtidal flow from Little Egg Inlet in the south to Pt. Pleasant Canal in the north due to frictional effects in the inlets, leading to better flushing of the southern half of the estuary and particle retention in the northern estuary. Mean residence time for BB-LEH was 13 days but spatial variability was between ∼0 and 30 days depending on the initial particle location. Mean residence time with tidal forcing alone was 24 days (spatial variability between ∼0 and 50 days); the tides were relatively inefficient in flushing the northern end of the Bay. Scenarios with successive exclusion of physical processes from the models revealed that meteorological and remote offshore forcing were stronger drivers of exchange than riverine inflow. Investigations of water quality and eutrophication should take into account spatial variability in hydrodynamics and residence time in order to better quantify the roles of nutrient loading, production, and flushing.
Comparison of three methods of sampling for endometrial cytology in the mare. Preliminary study.
Defontis, M; Vaillancourt, D; Grand, F X
2011-01-01
This prospective study aims to compare three different sampling techniques for the collection of endometrial cytological specimens in the mare: the guarded culture swab, the uterine cytobrush and the low volume uterine flush. The study population consisted of six healthy Standardbred mares in dioestrus. In each mare an acute endometritis was induced by performing a low- volume uterine flush 6days after ovulation using a sterile isotonic solution (lactated Ringer's solution or ViGro™ Complete Flush Solution). Two days after initiating inflammation, samples were collected from each mare using the three compared techniques: the double guarded cotton swab, the uterine cytobrush and the low volume uterine flush. The cytological evaluation of the samples was based on following criteria: the quality and cellularity of the samples and the number of neutrophils recovered. The uterine cytobrush yielded slides of significantly (p=0.02) better quality than the low volume uterine flush. There was no significant difference between the cytobrush and the double guarded swab technique for the quality. There was no difference between techniques in the number of endometrial cells (p=0.55) and neutrophils recovered (p=0.28). Endometrial cytology is a practical method for the diagnosis of acute endometrial inflammation in the mare. Since no difference in the number of neutrophils was found between the three techniques, the choice of the sampling method should be based on other factors such as practicability, costs and disadvantages of each technique.
Modeling tidal exchange and dispersion in Boston Harbor
Signell, Richard P.; Butman, Bradford
1992-01-01
Tidal dispersion and the horizontal exchange of water between Boston Harbor and the surrounding ocean are examined with a high-resolution (200 m) depth-averaged numerical model. The strongly varying bathymetry and coastline geometry of the harbor generate complex spatial patterns in the modeled tidal currents which are verified by shipboard acoustic Doppler surveys. Lagrangian exchange experiments demonstrate that tidal currents rapidly exchange and mix material near the inlets of the harbor due to asymmetry in the ebb/flood response. This tidal mixing zone extends roughly a tidal excursion from the inlets and plays an important role in the overall flushing of the harbor. Because the tides can only efficiently mix material in this limited region, however, harbor flushing must be considered a two step process: rapid exchange in the tidal mixing zone, followed by flushing of the tidal mixing zone by nontidal residual currents. Estimates of embayment flushing based on tidal calculations alone therefore can significantly overestimate the flushing time that would be expected under typical environmental conditions. Particle-release simulations from point sources also demonstrate that while the tides efficiently exchange material in the vicinity of the inlets, the exact nature of dispersion from point sources is extremely sensitive to the timing and location of the release, and the distribution of particles is streaky and patchlike. This suggests that high-resolution modeling of dispersion from point sources in these regions must be performed explicitly and cannot be parameterized as a plume with Gaussian-spreading in a larger scale flow field.
NASA Astrophysics Data System (ADS)
Agaoglu, B.; Scheytt, T. J.; Copty, N. K.
2011-12-01
This study examines the mechanistic processes governing multiphase flow of a water-cosolvent-NAPL system in saturated porous media. Laboratory batch and column flushing experiments were conducted to determine the equilibrium properties of pure NAPL and synthetically prepared NAPL mixtures as well as NAPL recovery mechanisms for different water-ethanol contents. The effect of contact time was investigated by considering different steady and intermittent flow velocities. A modified version of multiphase flow simulator (UTCHEM) was used to compare the multiphase model simulations with the column experiment results. The effect of employing different grid geometries (1D, 2D, 3D), heterogeneity and different initial NAPL saturation configurations were also examined in the model. It is shown that the change in velocity affects the mass transfer rate between phases as well as the ultimate NAPL recovery percentage. The experiments with slow flow rate flushing of pure NAPL and the 3D UTCHEM simulations gave similar effluent concentrations and NAPL cumulative recoveries. The results were less consistent for fast non-equilibrium flow conditions. The dissolution process from the NAPL mixture into the water-ethanol flushing solutions was found to be more complex than dissolution expressions incorporated in the numerical model. The dissolution rate of individual organic compounds (namely Toluene and Benzene) from a mixture NAPL into the ethanol-water flushing solution is found not to correlate with their equilibrium solubility values.The implications of this controlled experimental and modeling study on field cosolvent remediation applications are discussed.
Agaoglu, Berken; Scheytt, Traugott; Copty, Nadim K
2012-10-01
This study examines the mechanistic processes governing multiphase flow of a water-cosolvent-NAPL system in saturated porous media. Laboratory batch and column flushing experiments were conducted to determine the equilibrium properties of pure NAPL and synthetically prepared NAPL mixtures as well as NAPL recovery mechanisms for different water-ethanol contents. The effect of contact time was investigated by considering different steady and intermittent flow velocities. A modified version of multiphase flow simulator (UTCHEM) was used to compare the multiphase model simulations with the column experiment results. The effect of employing different grid geometries (1D, 2D, 3D), heterogeneity and different initial NAPL saturation configurations was also examined in the model. It is shown that the change in velocity affects the mass transfer rate between phases as well as the ultimate NAPL recovery percentage. The experiments with low flow rate flushing of pure NAPL and the 3D UTCHEM simulations gave similar effluent concentrations and NAPL cumulative recoveries. Model simulations over-estimated NAPL recovery for high specific discharges and rate-limited mass transfer, suggesting a constant mass transfer coefficient for the entire flushing experiment may not be valid. When multi-component NAPLs are present, the dissolution rate of individual organic compounds (namely, toluene and benzene) into the ethanol-water flushing solution is found not to correlate with their equilibrium solubility values. Copyright © 2012 Elsevier B.V. All rights reserved.
Comparing catchment hydrologic response to a regional storm using specific conductivity sensors
Inserillo, Ashley; Green, Mark B.; Shanley, James B.; Boyer, Joseph
2017-01-01
A better understanding of stormwater generation and solute sources is needed to improve the protection of aquatic ecosystems, infrastructure, and human health from large runoff events. Much of our understanding of water and solutes produced during stormflow comes from studies of individual, small headwater catchments. This study compared many different types of catchments during a single large event to help isolate landscape controls on streamwater and solute generation, including human-impacted land cover. We used a distributed network of specific electrical conductivity sensors to trace storm response during the post-tropical cyclone Sandy event of October 2012 at 29 catchments across the state of New Hampshire. A citizen science sensor network, Lotic Volunteer for Temperature, Electrical Conductivity, and Stage, provided a unique opportunity to investigate high-temporal resolution stream behavior at a broad spatial scale. Three storm response metrics were analyzed in this study: (a) fraction of new water contributing to the hydrograph; (b) presence of first flush (mobilization of solutes during the beginning of the rain event); and (c) magnitude of first flush. We compared new water and first flush to 64 predictor attributes related to land cover, soil, topography, and precipitation. The new water fraction was positively correlated with low and medium intensity development in the catchment and riparian buffers and with the precipitation from a rain event 9 days prior to Sandy. The presence of first flush was most closely related (positively) to soil organic matter. Magnitude of first flush was not strongly related to any of the catchment variables. Our results highlight the potentially important role of human landscape modification in runoff generation at multiple spatial scales and the lack of a clear role in solute flushing. Further development of regional-scale in situ sensor networks will provide better understanding of stormflow and solute generation across a wide range of landscape conditions.
Souza, Anna L M; Sampaio, Marcos; Noronha, Graciele B; Coster, Ludiana G R; de Oliveira, Roberta S G; Geber, Selmo
2017-10-01
The purpose of this study is to investigate the impact of follicular flushing on the number of oocytes retrieved, oocyte maturity, fertilization rate, embryo development, and pregnancy rate of poor ovarian responders (POR). Retrospective study of 524 cycles of 384 patients with POR submitted to assisted reproductive technology (ART) and who had follicular flushing during oocyte retrieval was used in the study. We included patients with <5 oocytes at oocyte retrieval (POR group) and matching the Bologna criteria. POR patients had a mean age of 38.2 ± 4.2 years. A total of 1355 follicles (mean = 3.5 ± 1.6) were aspirated and 1040 oocytes recovered, with 709 (68.2%) obtained by direct aspiration and 331 (31.8%) by follicular flushing. We found a difference between the total number of oocytes and the number of aspirated oocytes. Overall pregnancy rate was 22%. Association was observed between pregnancy rate and the number of oocytes retrieved, the number of MII oocytes, and the number of embryos transferred. The patients matching the Bologna criteria had a mean age of 38.9 ± 3.9 years. A total of 309 follicles were aspirated (mean = 3.1 ± 1.5) and 242 oocytes recovered, with 156 (64.5%) obtained by direct aspiration and 86 (35.5%) by follicular flushing. There was a significant difference between the total number of oocytes and the number of aspirated oocytes. Overall pregnancy rate was 12.1%. There was no association between the pregnancy rate and the number of oocytes retrieved, the number of MII, and the number of embryos. Follicular flushing might be a suitable alternative to increase the number of oocytes and pregnancy rates in patients with POR.
Reactive solute transport in an asymmetrical fracture-rock matrix system
NASA Astrophysics Data System (ADS)
Zhou, Renjie; Zhan, Hongbin
2018-02-01
The understanding of reactive solute transport in a single fracture-rock matrix system is the foundation of studying transport behavior in the complex fractured porous media. When transport properties are asymmetrically distributed in the adjacent rock matrixes, reactive solute transport has to be considered as a coupled three-domain problem, which is more complex than the symmetric case with identical transport properties in the adjacent rock matrixes. This study deals with the transport problem in a single fracture-rock matrix system with asymmetrical distribution of transport properties in the rock matrixes. Mathematical models are developed for such a problem under the first-type and the third-type boundary conditions to analyze the spatio-temporal concentration and mass distribution in the fracture and rock matrix with the help of Laplace transform technique and de Hoog numerical inverse Laplace algorithm. The newly acquired solutions are then tested extensively against previous analytical and numerical solutions and are proven to be robust and accurate. Furthermore, a water flushing phase is imposed on the left boundary of system after a certain time. The diffusive mass exchange along the fracture/rock matrixes interfaces and the relative masses stored in each of three domains (fracture, upper rock matrix, and lower rock matrix) after the water flushing provide great insights of transport with asymmetric distribution of transport properties. This study has the following findings: 1) Asymmetric distribution of transport properties imposes greater controls on solute transport in the rock matrixes. However, transport in the fracture is mildly influenced. 2) The mass stored in the fracture responses quickly to water flushing, while the mass stored in the rock matrix is much less sensitive to the water flushing. 3) The diffusive mass exchange during the water flushing phase has similar patterns under symmetric and asymmetric cases. 4) The characteristic distance which refers to the zero diffusion between the fracture and the rock matrix during the water flushing phase is closely associated with dispersive process in the fracture.
Channel Maintenance and Flushing Flows for the Klamath River Below Iron Gate Dam, California
Holmquist-Johnson, Cristopher L.; Milhous, Robert T.
2010-01-01
The Klamath River is a major river in northern California and southern Oregon. Iron Gate Dam divides the river into the two subunits where there is a significant change in utilization of the river. Downstream of Iron Gate Dam, the river is very important for the propagation of salmon. To address concerns relating to substrate conditions in the mainstem Klamath River below Iron Gate Dam, the Arcata, California, office of the U.S. Fish and Wildlife Service contracted with the U.S. Geological Survey (USGS) to determine flushing flows required to improve and maintain quality spawning and rearing habitats for salmon, and to reduce the abundance of preferred habitats of the polychaete worm suspected of being the intermediate host for Ceratomyxa shasta, a species of bacteria that infects fish. Historically, the river has had the capacity to move sediment just below Iron Gate Reservoir, but there have been periods when the capacity was very low. The results indicate that if the future is more like the pre-1961 period (low transport capacity) than the more recent period, there will be significant sediment issues in the Klamath River below Iron Gate Dam. It seems that during normal or wet years, winter months, and periods of high flow, sediments are flushed either downstream or deposited on higher surfaces. The recent drought conditions during 2000-2005 probably resulted in extensive fine-grained sedimentation along the river, which in turn may have caused increased establishment of aquatic vegetation and increased concentrations of C. shasta. It appears that releases from Iron Gate Dam as far downstream as Seiad Valley are important in maintaining flow conditions to flush the fines and clean the gravels in the river during summer months, or during drought years. Sediment transport studies indicate that supplemental flows during dry or drought conditions may provide some flushing flows in reaches downstream of the dam. For purposes of flushing fine sediments during drought years or dry summer months, flows in the range of 2,500-5,000 cubic feet per second during a period of days may be necessary. Providing these types of flows in a manner similar to a storm pulse would provide the best opportunity to flush the fines and clean some of the gravels given the upper ranges of flows are achieved.
Li, Songmin; Wang, Xiaoling; Qiao, Bin; Li, Jiansheng; Tu, Jiamin
2017-03-01
Nonpoint storm runoff remains a major threat to surface water quality in China. As a paddy matures, numerous fertilizers are needed, especially in the rainy seasons; the concentration of nitrogen and phosphorus in rainfall runoff from farmland is much higher than at other times, and this poses a great threat to water bodies and is the main reason for water eutrophication, especially in high concentration drainages. To date, most studies regarding the characteristics of pollutants in rainfall runoff have mainly been concentrated on urban runoff and watershed runoff; therefore, it is particularly important to investigate the characteristics of nitrogen and phosphorus loss in rainfall runoff from paddy fields. To study the characteristics of nitrogen and phosphorus loss and whether the first flush effect exists, continuous monitoring of the rainfall runoff process of six rainfall events was conducted in 2013, of which four rainfall events during storm, high, middle, and low intensity rainfalls were analyzed, and runoff and quality parameters, such as suspended solids (SS), total nitrogen (TN), ammonium nitrogen (NH 4 + -N), nitrate nitrogen (NO 3 - -N), total phosphorus (TP), and phosphate (PO 4 3- -P), were analyzed to determine the relationship between runoff and water quality. The paddy field is located north of Wuxi Lake Basin along the Hejia River upstream in Zhoutie town, Yixing city. An analysis of the load distribution during rainfall runoff was conducted. Event mean concentration (EMC) was used to evaluate the pollution situation of the paddy field's rainfall runoff. A curve of the dimensionless normalized cumulative load (L) vs. normalized cumulative flow (F) (L-F curve), the probability of the mass first flush (MFFn), and the pollutants carried by the initial 25% of runoff (FF 25 ) were used to analyze the first flush effect of the paddy field runoff, and different contaminants show different results: the concentration of nitrogen and phosphorus fluctuate and follow a similar trend as runoff changes, NO 3 - -N concentration is lower in the early part of runoff and higher in the later, and TP mainly occurs in the particle state in storm runoff and mainly in the dissolved state when the rainfall intensity is smaller. Nitrogen and phosphorus losses from paddy fields are closely related to the average rainfall intensity and the max rainfall intensity, and the runoff loss of nitrogen and phosphorus is more severe when the rainfall intensity is large. Based on an analysis of multiple methodologies, TN and NH 4 + -N show a certain degree of a first flush effect, whereas the first flush effect of TP is not obvious. The first flush effect of SS is obvious in larger intensity rainfall and shows a slight secondary flush effect in smaller rainfall events.
5. AERATOR VIEW FROM DOWNSTREAM. FLUSH VALVE AT RIGHT OPENS ...
5. AERATOR VIEW FROM DOWNSTREAM. FLUSH VALVE AT RIGHT OPENS TO CLEAR THE SYSTEM ABOVE THE SILT AND DEBRIS AND TO STOP THE FLOW OF WATER INTO THE SYSTEM DOWN LINE. BOX FLUME CONTINUES DOWN LINE TO SEDIMENTATION CHAMBER. - Kalaupapa Water Supply System, Waikolu Valley to Kalaupapa Settlement, Island of Molokai, Kalaupapa, Kalawao County, HI
USDA-ARS?s Scientific Manuscript database
The Asian citrus psyllid, Diaphorina citri (Hemiptera: Psyllidae) is a destructive insect mainly because it vectors the bacterial pathogens that cause the deadly and incurable citrus greening disease. Diaphorina citri adult females lay eggs and immature development occurs exclusively on new flush sh...
Flushing High School. A Basic Trilingual Program, 1981-1982. O.E.E. Evaluation Report.
ERIC Educational Resources Information Center
Torres, Judith A.; And Others
The Basic Trilingual Program at Flushing High School in Queens, New York City, provides instruction in English as a second language, native language arts instruction, and bilingual instruction in different content areas to Spanish speaking and Korean speaking high school students of limited English proficiency. The program is also involved in…
Developmental dynamics of longleaf pine seedling flushes and needles
Shi-Jean Susana Sung; Stanley J. Zarnoch; James D. Haywood; Daniel Leduc; Mary A. Sword-Sayer
2013-01-01
Longleaf pine (Pinus palustris Mill.) seedlings were grown for 27 weeks in containers of three cavity sizes and two cavity types (with and without copper coating) and then outplanted in central Louisiana in November 2004. Three seedlings from each plot were assessed repeatedly for shoot flush and needle development in 2007 and 2008. Cavity type had...
7. INTERIOR OF LIVING ROOM SHOWING FLUSH FRONT DOOR AT ...
7. INTERIOR OF LIVING ROOM SHOWING FLUSH FRONT DOOR AT PHOTO CENTER, MODERN SIDING WINDOW ON EAST WALL (FORMER PORCH) AT PHOTO CENTER RIGHT, AND ORIGINAL PAIRED 6-LIGHT OVER 1-LIGHT WINDOWS ON NORTH WALL (PHOTO LEFT). VIEW TO NORTHEAST. - Bishop Creek Hydroelectric System, Control Station, Worker Cottage, Bishop Creek, Bishop, Inyo County, CA
Safety and Efficacy of Topical Chitogel- Deferiprone-Gallium Protoporphyrin in Sheep Model
Ooi, Mian L.; Richter, Katharina; Drilling, Amanda J.; Thomas, Nicky; Prestidge, Clive A.; James, Craig; Moratti, Stephen; Vreugde, Sarah; Psaltis, Alkis J.; Wormald, Peter-John
2018-01-01
Objectives: Increasing antimicrobial resistance has presented new challenges to the treatment of recalcitrant chronic rhinosinusitis fuelling a continuous search for novel antibiofilm agents. This study aimed to assess the safety and efficacy of Chitogel (Chitogel®, Wellington New Zealand) combined with novel antibiofilm agents Deferiprone and Gallium Protoporphyrin (CG-DG) as a topical treatment against S. aureus biofilms in vivo. Methods: To assess safety, 8 sheep were divided into two groups of 7 day treatments (n = 8 sinuses per treatment); (1) Chitogel (CG) with twice daily saline flush, and (2) CG-DG gel with twice daily saline flush. Tissue morphology was analyzed using histology and scanning electron microscopy (SEM). To assess efficacy we used a S. aureus sheep sinusitis model. Fifteen sheep were divided into three groups of 7 day treatments (n = 10 sinuses per treatment); (1) twice daily saline flush (NT), (2) Chitogel (CG) with twice daily saline flush, and (3) CG-DG gel with twice daily saline flush. Biofilm biomass across all groups was compared using LIVE/DEAD BacLight stain and confocal scanning laser microscopy. Results: Safety study showed no cilia denudation on scanning electron microscopy and no change in sinus mucosa histopathology when comparing CG-DG to CG treated sheep. COMSTAT2 assessment of biofilm biomass showed a significant reduction in CG-DG treated sheep compared to NT controls. Conclusion: Results indicate that CG-DG is safe and effective against S. aureus biofilms in a sheep sinusitis model and could represent a viable treatment option in the clinical setting.
Friedler, Eran; Gilboa, Yael
2010-04-01
This paper examines the microbial quality of treated RBC (Rotating Biological Contactor) and MBR (Membrane Bioreactor) light greywater along a continuous pilot-scale reuse system for toilet flushing, quantifies the efficiency of UV disinfection unit, and evaluates the regrowth potential of selected microorganisms along the system. The UV disinfection unit was found to be very efficient in reducing faecal coliforms and Staphylococcus aureus. On the other hand, its efficiency of inactivation of HPC (Heterotrophic Plate Count) and Pseudomonas aeruginosa was lower. Some regrowth occurred in the reuse system as a result of HPC regrowth which included opportunistic pathogens such as P. aeruginosa. Although the membrane (UF) of the MBR system removed all bacteria from the greywater, bacteria were observed in the reuse system due to "hopping phenomenon." The microbial quality of the disinfected greywater was found to be equal or even better than the microbial quality of "clean" water in toilet bowls flushed with potable water (and used for excretion). Thus, the added health risk associated with reusing the UV-disinfected greywater for toilet flushing (regarding P. aeruginosa and S. aureus), was found to be insignificant. The UV disinfection unit totally removed (100%) the viral indicator (F-RNA phage, host: E. coli F(amp)(+)) injected to the treatment systems simulating transient viral contamination. To conclude, this work contributes to better design of UV disinfection reactors and provides an insight into the long-term behavior of selected microorganisms along on-site greywater reuse systems for toilet flushing. (c) 2010 Elsevier B.V. All rights reserved.
Guiffant, Gérard; Durussel, Jean Jacques; Flaud, Patrice; Royon, Laurent; Marcy, Pierre Yves; Merckx, Jacques
2013-01-01
The use of totally implantable venous access devices (TIVADs) certified as "high pressure resistant" or "power port" has begun to spread worldwide as a safe procedure for power contrast injection. Owing to the thermo-rheological properties of the contrast media, the primary aim of this work is to present an in vitro experimental impact study concerning the impact of the temperature level on flushing efficiency after contrast medium injection. Moreover, we report experimental data that confirms the role of needle bevel orientation. The secondary aim is to answer the following questions: Is there significant device contrast medium trapping after contrast medium injection? Is saline flushing efficient? And, finally, is it safe to inject contrast medium through an indwelled port catheter? The experimental results show that in addition to hydrodynamics, temperature is a key parameter for the efficiency of device flushing after contrast medium injection. It appears that this is the case when the cavity is incompletely rinsed after three calibrated flushing volumes of 10 mL saline solution, even by using the Huber needle bevel opposite to the port exit. This leads to a potentially important trapped volume of contrast medium in the port, and consequently to the possibility of subsequent salt precipitates and long term trisubstituted benzene nuclei delivery that might impair the solute properties, which may be further injected via the power port later on. We thus suggest, in TIVADS patients, the use of a temporary supplementary intravenous line rather than the port to perform contrast medium injections in daily radiology routine practice.
Guiffant, Gérard; Durussel, Jean Jacques; Flaud, Patrice; Royon, Laurent; Marcy, Pierre Yves; Merckx, Jacques
2013-01-01
Purpose The use of totally implantable venous access devices (TIVADs) certified as “high pressure resistant” or “power port” has begun to spread worldwide as a safe procedure for power contrast injection. Owing to the thermo-rheological properties of the contrast media, the primary aim of this work is to present an in vitro experimental impact study concerning the impact of the temperature level on flushing efficiency after contrast medium injection. Moreover, we report experimental data that confirms the role of needle bevel orientation. The secondary aim is to answer the following questions: Is there significant device contrast medium trapping after contrast medium injection? Is saline flushing efficient? And, finally, is it safe to inject contrast medium through an indwelled port catheter? Results The experimental results show that in addition to hydrodynamics, temperature is a key parameter for the efficiency of device flushing after contrast medium injection. It appears that this is the case when the cavity is incompletely rinsed after three calibrated flushing volumes of 10 mL saline solution, even by using the Huber needle bevel opposite to the port exit. This leads to a potentially important trapped volume of contrast medium in the port, and consequently to the possibility of subsequent salt precipitates and long term trisubstituted benzene nuclei delivery that might impair the solute properties, which may be further injected via the power port later on. Conclusion We thus suggest, in TIVADS patients, the use of a temporary supplementary intravenous line rather than the port to perform contrast medium injections in daily radiology routine practice. PMID:24043959
Brown, Lydia; Bryant, Christina; Brown, Valerie; Bei, Bei; Judd, Fiona
2015-06-01
A large body of work has investigated the relationship between menopausal factors and negative well-being (e.g. anxiety and depressive symptoms), but less is known about positive well-being and its correlates among midlife women. This study tests two models with both positive and negative well-being indices as outcomes: the first included menopausal factors as predictors; the second model expanded the first by adding self-compassion, a protective trait, as a predictor and moderator. Cross-sectional study based on self-report questionnaires from 206 women aged 40-60, currently experiencing hot flushes. Hot flush interference ratings, emotional balance, satisfaction with life, eudaimonic well-being and depressive symptoms. In model one, menopausal stage and hot flush frequency were independent of well-being outcomes. Beliefs about perceived control over menopause was the strongest predictor of well-being (β range: .22-.32), followed by hot flush interference ratings (β range: .15-.33). In model two, self-compassion was the strongest predictor of well-being indices (β range: .20-.39), followed by beliefs about control (β range: .16-.20) and interference ratings (β range: .17-.26). Psychological aspects of the menopause appear more strongly linked to well-being than physiological aspects such as menopausal stage and hot flush frequency. Specifically, self-compassion, feeling in control of menopause and low interference ratings are three factors that are associated with well-being among midlife women. These aspects could be considered in tandem, as a means to support well-being in the context of menopause. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Fournier, Agnès; Fritel, Xavier; Panjo, Henri; Zins, Marie; Ringa, Virginie
2014-07-01
After we demonstrated a substantial drop in postmenopausal hormone therapy (HT) in France after 2002, we sought to compare health characteristics assessed before menopause and reasons for beginning treatment among women who started postmenopausal HT before and after this year. Among participants of the GAZEL (GAZ and ELectricité) cohort of employees of the French national power company, we studied 1,229 women who reached menopause before 2002 and 562 women who reached menopause after 2002. We analyzed HT use among these newly postmenopausal women before and after 2002 and its relations to self-rated health, simple and troublesome hot flushes, and various other symptoms before menopause. After 2002, compared with before 2002, women starting HT were more likely to have reported troublesome hot flushes before menopause (odds ratio, 2.3; 95% CI, 1.0-5.4). The groups of new HT users did not differ significantly except for health characteristics. Significantly higher proportions of women starting HT reported using it for hot flushes (68.1% vs 52.9%, P = 0.02) and sleep disorders (11.1% vs 2.8%, P = 0.001) and a significantly lower proportion of women starting HT reported using it for osteoporosis prevention (12.5% vs 43.9%, P < 0.001) after 2002 than before 2002. After 2002, HT tended to be prescribed for more severe hot flushes, but almost one third of prescriptions were still written for reasons not linked to hot flushes. Doctors seem to be following recommendations to not use HT as a first-line treatment of osteoporosis.
Nashida, Norihiro; Satoh, Wataru; Fukuda, Junji; Suzuki, Hiroaki
2007-06-15
An integrated microfluidic device with injecting, flushing, and sensing functions was realized using valves that operate based on direct electrowetting. The device consisted of two substrates: a glass substrate with driving and sensing electrodes and a poly(dimethylsiloxane) (PDMS) substrate. Microfluidic transport was achieved using the spontaneous movement of solutions in hydrophilic flow channels formed with a dry-film photoresist layer. The injection and flushing of solutions were controlled by gold working electrodes, which functioned as valves. The valves were formed either in the channels or in a through-hole in the glass substrate. To demonstrate the system's applicability to an immunoassay, the detection of immobilized antigens was performed as a partial simulation of a sandwich immunoassay. Human alpha-fetoprotein (AFP) or an anti-human AFP antibody was immobilized on a platinum working electrode in the chamber using a plasma-polymerized film (PPF). By applying a potential to the injection valves, necessary solutions were injected one by one through the channels into a reaction chamber at the center of the chip and incubated for reasonable periods of time. The solutions were then flushed through the flushing valve and absorbed in a filter paper placed under the device. After incubation with the corresponding antibodies labeled with glucose oxidase (GOD), electrochemical detection was conducted. In both cases, the obtained current depended on the amount of immobilized antigen. The calibration curves were sigmoidal, and the detection limit was 0.1 ng. The developed microfluidic system could potentially be a fundamental component for a micro immunoassay of the next generation.
Hellige, G
1976-01-01
The experimentally in vitro determined dynamic response characteristics of 38 catheter manometer systems were uniform in the worst case to 5 c.p.s. and optimally to 26 c.p.s. Accordingly, some systems are only satisfactory for ordinary pressure recording in cardiac rest, while better systems record dp/dt correct up to moderate inotropic stimulation of the heart. In the frequency range of uniform response (amplitude error less +/- 5%) the phase distortion is also negligible. In clinical application the investigator is often restricted to special type of cardiac catheter. In this case a low compliant transducer yields superior results. In all examined systems the combination with MSD 10 transducers is best, whereas the combination with P 23 Db transducers leads to minimal results. An inadequate system for recording ventricular pressure pulses leads in most cases to overestimations of dp/dtmax. The use of low frequency pass filters to attenuate higher frequency artefacts is, under clinical conditions, not suitable for extending the range of uniform frequency response. The dynamic response of 14 catheter manometer systems with two types of continuous self flush units was determined. The use of the P 37 flush unit in combination with small internal diameter catheters leads to serious error in ordinary pressure recording, due to amplitude distortion of the lower harmonics. The frequency response characteristics of the combination of an Intraflow flush system and MSD 10 transducer was similar to the non-flushing P 23 Db transducer feature.
Dispersion patterns and sampling plans for Diaphorina citri (Hemiptera: Psyllidae) in citrus.
Sétamou, Mamoudou; Flores, Daniel; French, J Victor; Hall, David G
2008-08-01
The abundance and spatial dispersion of Diaphorina citri Kuwayama (Hemiptera: Psyllidae) were studied in 34 grapefruit (Citrus paradisi Macfad.) and six sweet orange [Citrus sinensis (L.) Osbeck] orchards from March to August 2006 when the pest is more abundant in southern Texas. Although flush shoot infestation levels did not vary with host plant species, densities of D. citri eggs, nymphs, and adults were significantly higher on sweet orange than on grapefruit. D. citri immatures also were found in significantly higher numbers in the southeastern quadrant of trees than other parts of the canopy. The spatial distribution of D. citri nymphs and adults was analyzed using Iowa's patchiness regression and Taylor's power law. Taylor's power law fitted the data better than Iowa's model. Based on both regression models, the field dispersion patterns of D. citri nymphs and adults were aggregated among flush shoots in individual trees as indicated by the regression slopes that were significantly >1. For the average density of each life stage obtained during our surveys, the minimum number of flush shoots per tree needed to estimate D. citri densities varied from eight for eggs to four flush shoots for adults. Projections indicated that a sampling plan consisting of 10 trees and eight flush shoots per tree would provide density estimates of the three developmental stages of D. citri acceptable enough for population studies and management decisions. A presence-absence sampling plan with a fixed precision level was developed and can be used to provide a quick estimation of D. citri populations in citrus orchards.
Safety and Efficacy of Topical Chitogel- Deferiprone-Gallium Protoporphyrin in Sheep Model.
Ooi, Mian L; Richter, Katharina; Drilling, Amanda J; Thomas, Nicky; Prestidge, Clive A; James, Craig; Moratti, Stephen; Vreugde, Sarah; Psaltis, Alkis J; Wormald, Peter-John
2018-01-01
Objectives: Increasing antimicrobial resistance has presented new challenges to the treatment of recalcitrant chronic rhinosinusitis fuelling a continuous search for novel antibiofilm agents. This study aimed to assess the safety and efficacy of Chitogel (Chitogel®, Wellington New Zealand) combined with novel antibiofilm agents Deferiprone and Gallium Protoporphyrin (CG-DG) as a topical treatment against S. aureus biofilms in vivo . Methods: To assess safety, 8 sheep were divided into two groups of 7 day treatments ( n = 8 sinuses per treatment); (1) Chitogel (CG) with twice daily saline flush, and (2) CG-DG gel with twice daily saline flush. Tissue morphology was analyzed using histology and scanning electron microscopy (SEM). To assess efficacy we used a S. aureus sheep sinusitis model. Fifteen sheep were divided into three groups of 7 day treatments ( n = 10 sinuses per treatment); (1) twice daily saline flush (NT), (2) Chitogel (CG) with twice daily saline flush, and (3) CG-DG gel with twice daily saline flush. Biofilm biomass across all groups was compared using LIVE/DEAD BacLight stain and confocal scanning laser microscopy. Results: Safety study showed no cilia denudation on scanning electron microscopy and no change in sinus mucosa histopathology when comparing CG-DG to CG treated sheep. COMSTAT2 assessment of biofilm biomass showed a significant reduction in CG-DG treated sheep compared to NT controls. Conclusion: Results indicate that CG-DG is safe and effective against S. aureus biofilms in a sheep sinusitis model and could represent a viable treatment option in the clinical setting.
A mechanistic assessment of nutrient flushing at the catchment scale
Willem J. van Verseveld; Jeffrey J. McDonnell; Kate Lajtha
2008-01-01
This paper mechanistically assesses the flushing mechanism of DOC, DON, and DIN at the hillslope and catchment scales during two storm events, in a small catchment (WS10), H.J. Andrews Experimental Forest in the western Cascade Mountains of Oregon. Using a combination of natural tracer and hydrometric data, and end-member mixing analysis, we were able to describe the...
NASA Technical Reports Server (NTRS)
Montoya, L. C.; Lux, D. P.
1975-01-01
Wing pressure distributions obtained in flight with flush orifice and external tubing orifice installations for Mach numbers from 0.50 to 0.97 are compared. The procedure used to install the external tubing orifice is discussed. The results indicate that external tubing orifice installations can give useful results.
Flushing High School, A Basic Trilingual Program. O.E.E. Evaluation Report, 1982-1983.
ERIC Educational Resources Information Center
Inman, Deborah; Schulman, Robert
In 1982-83, the Basic Trilingual Program at Flushing High School in Queens, New York, provided instruction in English as a Second Language (ESL) in 185 Hispanic and 51 Korean students of limited English proficiency in grades 9-12. The Hispanic students attended native language classes and bilingual courses in social studies, math, science, art,…
The purpose of this paper is to present an overview and the initial results of a pilot-scale experiment designated to test the use of cyclodextrin for enhanced in-situ flushing of an aquifer contaminated by immiscible liquid. This is the first field test of this technology, terme...
Erwin, R.M.
1989-01-01
Colonies of nesting wading birds and seabirds were studied at coastal sites in Virginia and North Carolina to determine distances at which birds flushed in response to human intrusion. There were few statistically significant relationships between flushing distances and colony size. Similarly, there were few differences between responses during incubation compared to post-hatching periods.
A study of the complications of small bore 'Seldinger' intercostal chest drains.
Davies, Helen E; Merchant, Shairoz; McGown, Anne
2008-06-01
Use of small bore chest drains (<14F), inserted via the Seldinger technique, has increased globally over the last few years. They are now used as first line interventions in most acute medical situations when thoracostomy is required. Limited data are available on the associated complications. In this study, the frequency of complications associated with 12F chest drains, inserted using the Seldinger technique, was quantified. A retrospective case note audit was performed of consecutive patients requiring pleural drainage over a 12-month period. One hundred consecutive small bore Seldinger (12F) chest drain insertions were evaluated. Few serious complications occurred. However, 21% of the chest drains were displaced ('fell out') and 9% of the drains became blocked. This contributed to high morbidity rates, with 13% of patients requiring repeat pleural procedures. The frequency of drain blockage in pleural effusion was reduced by administration of regular normal saline drain flushes (odds ratio for blockage in flushed drains compared with non-flushed drains 0.04, 95% CI: 0.01-0.37, P < 0.001). Regular chest drain flushes are advocated in order to reduce rates of drain blockage, and further studies are needed to determine optimal fixation strategies that may reduce associated patient morbidity.
Probability mass first flush evaluation for combined sewer discharges.
Park, Inhyeok; Kim, Hongmyeong; Chae, Soo-Kwon; Ha, Sungryong
2010-01-01
The Korea government has put in a lot of effort to construct sanitation facilities for controlling non-point source pollution. The first flush phenomenon is a prime example of such pollution. However, to date, several serious problems have arisen in the operation and treatment effectiveness of these facilities due to unsuitable design flow volumes and pollution loads. It is difficult to assess the optimal flow volume and pollution mass when considering both monetary and temporal limitations. The objective of this article was to characterize the discharge of storm runoff pollution from urban catchments in Korea and to estimate the probability of mass first flush (MFFn) using the storm water management model and probability density functions. As a result of the review of gauged storms for the representative using probability density function with rainfall volumes during the last two years, all the gauged storms were found to be valid representative precipitation. Both the observed MFFn and probability MFFn in BE-1 denoted similarly large magnitudes of first flush with roughly 40% of the total pollution mass contained in the first 20% of the runoff. In the case of BE-2, however, there were significant difference between the observed MFFn and probability MFFn.
Indicate severe toxicity of highway runoff.
Dorchin, Achik; Shanas, Uri
2013-09-01
Road runoff is recognized as a substantial nonpoint source of contamination to the aquatic environment. Highway seasonal first flushes contain particularly high concentrations of pollutants. To fully account for the toxicity potential of the runoff, the cumulative effects of the pollutants should be assessed, ideally by biological analyses. Acute toxicity tests with were used to measure the toxicity of runoff from three major highway sections in Israel for 2 yr. Highway first flushes resulted in the mortality of all tested individuals within 24 to 48 h. A first flush collected from Highway 4 (traffic volume: 81,200 cars d) remained toxic even after dilution to <5% (48 h EC <5%). Synthetic solutions with metal concentrations corresponding to highways' first flushes revealed a synergistic adverse effect on survival and a potential additive effect of nonmetal pollutants in the runoff. Because daphnids and other invertebrates constitute the base of the aquatic food chain, detrimental effects of highway runoff may propagate to higher levels of biological organization. The observed high potential of environmental contamination warrants the control of highway runoff in proximity to natural watercourses. Copyright © by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America, Inc.
Maire, Julien; Joubert, Antoine; Kaifas, Delphine; Invernizzi, Thomas; Marduel, Julien; Colombano, Stéfan; Cazaux, David; Marion, Cédric; Klein, Pierre-Yves; Dumestre, Alain; Fatin-Rouge, Nicolas
2018-01-15
Immiscible mobilization and foam flushing were assessed as low surfactant consuming technologies, for the enhanced recovery of dense non-aqueous phase liquid (DNAPL) residual at a site contaminated by heavy chlorinated compounds. Preliminary experiments in well-controlled conditions demonstrated the phenomena involved in these remediation technologies and their limitations. Furthermore, we characterized the technologies according to by their surfactant consumption (per kg of DNAPL recovered) and the final DNAPL saturation reached. Surfactant foam flushing (SFF) produced lower DNAPL saturation than immiscible mobilization, thanks to its higher viscosity. However, its efficiency is strongly correlated to the pressure gradient (▽P) used during injection, and that is limited by risks of soil fracturing. The two technologies were tested in field cells (10m×10m×10m) delimited by cement/bentonite walls anchored in the clayey substratum. The deepest soil layer was the most contaminated. It was composed of silt-sandy soil and had an average hydraulic conductivity of 10 -4 ms -1 . Field results show that we should now model flushing fluid propagation to design efficient set-ups for recovering the displaced DNAPL. Copyright © 2017 Elsevier B.V. All rights reserved.
Wild turkey poult survival in southcentral Iowa
Hubbard, M.W.; Garner, D.L.; Klaas, E.E.
1999-01-01
Poult survival is key to understanding annual change in wild turkey (Meleagris gallopavo) populations. Survival of eastern wild turkey poults (M. g. silvestris) 0-4 weeks posthatch was studied in southcentral Iowa during 1994-97. Survival estimates of poults were calculated based on biweekly flush counts and daily locations acquired via radiotelemetry. Poult survival averaged 0.52 ?? 0.14% (?? ?? SE) for telemetry counts and 0.40 ?? 0.15 for flush counts. No within-year or across-year differences were detected between estimation techniques. More than 72% (n = 32) of documented poult mortality occurred ???14 days posthatch, and mammalian predation accounted for 92.9% of documented mortality. If mortality agents are not of concern, we suggest biologists conduct 4-week flush counts to obtain poult survival estimates for use in population models and development of harvest recommendations.
NASA Technical Reports Server (NTRS)
Ali, Aliyah N.; Borrer, Jerry L.
2013-01-01
This presentation presents information regarding the nose-cap flush airdata sensing (FADS) system on Orion's Pad Abort 1 (PA-1) vehicle. The purpose of the nose-cap FADS system was to test whether or not useful data could be obtained from a FADS system if it was placed in close proximity to firing rockets nozzles like the attitude control motor (ACM) nozzles on the PA-1 launch abort system (LAS). The nose-cap FADS systems use pressure measurements from a series of pressure ports which are arranged in a cruciform pattern and flush with the surface of the vehicle to estimate values of angle of attack, angle of side-slip, Mach number, impact pressure and free-stream static pressure.
Cavity-backed, micro-strip dipole antenna array
NASA Technical Reports Server (NTRS)
Ellis, H., Jr. (Inventor)
1981-01-01
A flush-mounted antenna assembly includes a generally rectangular, conductive, box structure open along one face to form a cavity. Within the cavity a pair of mutually orthogonal dielectric plane surfaces in an "egg crate" arrangement are mounted normal to the plane of the open face, each diagonally within the cavity. Each dielectric plane supports a pair of printed circuit dipoles typically each fed from the opposite side of the dielectric plane by a printed "cone-shaped" feed line trace which also serve as an impedance matching device and functions as a balun connected from an unbalanced strip line external feed. The open face of the conductive cavity can be flush mounted with a randome thereover, the assembly thereby being flush with the skin of a aircraft or space vehicle.
Cavity-backed, micro-strip dipole antenna array
NASA Astrophysics Data System (ADS)
Ellis, H., Jr.
1981-09-01
A flush-mounted antenna assembly includes a generally rectangular, conductive, box structure open along one face to form a cavity. Within the cavity a pair of mutually orthogonal dielectric plane surfaces in an "egg crate" arrangement are mounted normal to the plane of the open face, each diagonally within the cavity. Each dielectric plane supports a pair of printed circuit dipoles typically each fed from the opposite side of the dielectric plane by a printed "cone-shaped" feed line trace which also serve as an impedance matching device and functions as a balun connected from an unbalanced strip line external feed. The open face of the conductive cavity can be flush mounted with a randome thereover, the assembly thereby being flush with the skin of a aircraft or space vehicle.
Contribution of the bronchial circulation to lung preservation.
LoCicero, J; Massad, M; Matano, J; Greene, R; Dunn, M; Michaelis, L L
1991-05-01
Short preservation time still severely limits lung transplantation. To determine the effect of bronchial arterial flush preservation, we studied 54 dogs using the isolated perfused working lung model. After baseline measurements, lungs were flushed with lactated Ringer's solution (60 ml/kg at 8 degrees C) by one of three methods: pulmonary artery perfusion, bronchial artery perfusion through a 15 cm closed aortic segment, or simultaneous pulmonary-bronchial artery perfusion. These groups were further subdivided and tested after 0, 4, and 17 hours of storage at 4 degrees C (n = 6 each). Lungs were ventilated (flow rate 140 ml/kg/min; inspired oxygen fraction 0.21) and continuously reperfused with normothermic deoxygenated autologous blood in a closed loop. Measured variables were hemodynamics, aerodynamics, and leukocytes in bronchoalveolar lavage. Survival time was determined from initial reperfusion to failure of the lung to oxygenate. After 0 and 4 hours of storage, there was no significant difference in survival times. After 17 hours, lungs subjected to pulmonary-bronchial artery perfusion survived longer than those perfused via either the pulmonary or bronchial arteries alone (120 +/- 24 versus 38 +/- 14 or 52 +/- 16 minutes; p less than 0.01). Pulmonary artery pressure and resistance in all groups except at failure were never different from baseline values in the intact animal. Shunts in the pulmonary-bronchial artery perfusion groups were closest to baseline at onset (8% +/- 4%) and remained lower throughout reperfusion than in the groups subjected to pulmonary or bronchial artery perfusion alone. After 17 hours, static compliance of pulmonary artery-perfused lungs was worse than baseline (1.1 +/- 0.2 x 10(-2) versus 3.2 +/- 0.7 x 10(-2) L/cm H2O/sec; p less than 0.05), whereas compliance in the pulmonary-bronchial artery perfusion groups remained constant (3.6 +/- 1.5 x 10(-2) L/cm H2O/sec). Elastic work performed by lungs subjected to pulmonary-bronchial artery flushing at onset was significantly lower when these lungs were reperfused immediately (201 +/- 14 versus 295 +/- 35 gm-m/min for pulmonary artery-flushed lungs) or after 4 hours of storage (229 +/- 30 versus 290 +/- 24 gm-m/min for pulmonary artery-flushed lungs). Bronchoalveolar lavage after 17 hours in the group subjected to pulmonary bronchial artery flushing demonstrated leukocyte counts similar to those of intact lungs (45 +/- 5 versus 29 +/- 8/mm3) and significantly less than in lungs subjected to pulmonary or bronchial artery flushing (137 +/- 18 or 82 +/- 10/mm3, respectively).(ABSTRACT TRUNCATED AT 400 WORDS)
Army Net Zero Prove Out. Net Zero Waster Best Practices
2014-11-18
harvested for non-potable uses such as toilet flushing in buildings, cooling towers and irrigation. Implementation of these solutions should not...potable uses such as toilet flushing in buildings, cooling towers and irrigation. Implementation of these solutions should not increase overall...collection of information is estimated to average 1 hour per response, including the time for reviewing instructions, searching existing data sources
Determination of Algorithm Parallelism in NP Complete Problems for Distributed Architectures
1990-03-05
12 structure STACK declare OpenStack (S-.NODE **TopPtr) -+TopPtrI FlushStack(S.-NODE **TopPtr) -*TopPtr PushOnStack(S-.NODE **TopPtr, ITEM *NewltemPtr...OfCoveringSets, CoveringSets, L, Best CoverTime, Vertex, Set3end SCND ADT B.26 structure STACKI declare OpenStack (S-NODE **TopPtr) -+TopPtr FlushStack(S
USDA-ARS?s Scientific Manuscript database
When operating water recirculating systems (RAS) with high make-up water flushing rates in locations that have low alkalinity in the raw water, such as Norway, knowledge about the required RAS alkalinity concentration is important. Flushing RAS with make-up water containing low alkalinity washes out...
Flush Development Dynamics in First-Year Nursery-Grown Seedlings of Eight Oak Species
Shi-Jean S. Sung; Paul P. Kormanik; Stanley J. Zarnoch
2004-01-01
Two experiments were conducted to follow flush development dynamics exhibited by various oak species. In experiment I, southern red oak acorns were sown in mid-March 2001 at Whitehall Nursery (Athens, GA). In experiment II, acorns of black oak, cherrybark oak, Nuttall oak, Shumard oak, southern red oak, swamp chestnut oak, white oak, and willow oak were sown in...
2003-01-01
dysp = Dyspnea euph = euphoria excitement = excited fib = fibrosis flush face = flush face ftg = fatigue Head = Headache Gidd = giddiness inco...nausea Neck = neck ache nose = irritated nose Pallor Pulm edema= pulmonar y edema Resp sys = Respiratory System skin = irritated skin som = somnolence
Estuarine turbidity, flushing, salinity, and circulation
NASA Technical Reports Server (NTRS)
Pritchard, D. W.
1972-01-01
The effects of estuarine turbidity, flushing, salinity, and circulation on the ecology of the Chesapeake Bay are discussed. The sources of fresh water, the variations in salinity, and the circulation patterns created by temperature and salinity changes are analyzed. The application of remote sensors for long term observation of water temperatures is described. The sources of sediment and the biological effects resulting from increased sediments and siltation are identified.
Fenlon, Deborah; Nuttall, Jacqueline; May, Carl; Raftery, James; Fields, Jo; Kirkpatrick, Emma; Abab, Julia; Ellis, Mary; Rose, Taylor; Khambhaita, Priya; Galanopoulou, Angeliki; Maishman, Tom; Haviland, Jo; Griffiths, Gareth; Turner, Lesley; Hunter, Myra
2018-05-08
Women who have been treated for breast cancer may identify vasomotor symptoms, such as hot flushes and night sweats (HFNS), as a serious problem. HFNS are unpleasant to experience and can have a significant impact on daily life, potentially leading to reduced adherence to life saving adjuvant hormonal therapy. It is known that Cognitive Behavioural Therapy (CBT) is effective for the alleviation of hot flushes in both well women and women who have had breast cancer. Most women with breast cancer will see a breast care nurse and there is evidence that nurses can be trained to deliver psychological treatments to a satisfactory level, whilst also maintaining treatment fidelity. The research team will assess whether breast care nurses can effectively deliver a CBT intervention to alleviate hot flushes in women with breast cancer. This study is a multi-centre phase III individually randomised controlled trial of group CBT versus usual care to reduce the impact of hot flushes in women with breast cancer. 120-160 women with primary breast cancer experiencing seven or more problematic HFNS a week will be randomised to receive either treatment as usual (TAU) or participation in the group CBT intervention plus TAU (CBT Group). A process evaluation using May's Normalisation Process Theory will be conducted, as well as practical and organisational issues relating to the implementation of the intervention. Fidelity of implementation of the intervention will be conducted by expert assessment. The cost effectiveness of the intervention will also be assessed. There is a need for studies that enable effective interventions to be implemented in practice. There is good evidence that CBT is helpful for women with breast cancer who experience HFNS, yet it is not widely available. It is not yet known whether the intervention can be effectively delivered by breast care nurses or implemented in practice. This study will provide information on both whether the intervention can effectively help women with hot flushes and whether and how it can be translated into routine clinical practice. ISRCTN 12824632 . Registered 25-01-2017.
Strati, Sara; Patiño, Sandra; Slidders, Caley; Cundall, Edward P; Mencuccini, Maurizio
2003-07-01
Silver birch (Betula pendula Roth) is increasingly used in the United Kingdom for reforestation. However, recent evidence indicates that, under some circumstances, planted birch can suffer serious and repeated mortality of the apical leaders and branches, with consequent loss of apical dominance and the formation of a contorted stem. Plants from 37 seed sources of silver birch from Scotland and northern England planted at two sites were compared for several characteristics related to hydraulic architecture, vulnerability to freeze-thaw cycle induced embolism and spring recovery from winter embolism during the period 2000-2002. Phenological rhythms were also monitored in late winter-early spring to document relationships between phenology and water relations parameters. Significant differences were found across seed sources in stage of bud flushing for four dates in spring. Early flushing seed sources differed by about 1 to 2 weeks from late-flushing seed sources across the two sites. Wintertime xylem embolism in stems reached a peak of about 50 to 70% loss of xylem hydraulic conductivity, depending on the size and position of the sample shoots in the canopy. Small apical shoots were significantly more embolized than large basal shoots. Development of winter embolism was coupled to the occurrence of frost events. As percent loss of hydraulic conductivity increased during the winter, wood relative water content declined. Embolism reversal occurred rapidly in spring at the time of development of positive root pressure. No significant differences in the degree of winter embolism in 2001 were found among the three seed sources examined. The investigation was expanded in the winter-spring of 2002 to include 10 seed sources across both sites. Significant differences were found in degree of winter embolism across sites, dates and seed sources. For each date, there was a significant relationship between flushing scores and wood relative water contents across the two sites and all seed sources, suggesting that differences in time of flushing across sites and seed sources were likely caused by differences in the time of occurrence of root pressure, a necessary precondition to flushing.
Molybdenum distributions and variability in drinking water from England and Wales.
Smedley, P L; Cooper, D M; Lapworth, D J
2014-10-01
An investigation has been carried out of molybdenum in drinking water from a selection of public supply sources and domestic taps across England and Wales. This was to assess concentrations in relation to the World Health Organization (WHO) health-based value for Mo in drinking water of 70 μg/l and the decision to remove the element from the list of formal guideline values. Samples of treated drinking water from 12 water supply works were monitored up to four times over an 18-month period, and 24 domestic taps were sampled from three of their supply areas. Significant (p < 0.05) differences were apparent in Mo concentration between sources. Highest concentrations were derived from groundwater from a sulphide-mineralised catchment, although concentrations were only 1.5 μg/l. Temporal variability within sites was small, and no seasonal effects (p > 0.05) were detected. Tap water samples collected from three towns (North Wales, the English Midlands, and South East England) supplied uniquely by upland reservoir water, river water, and Chalk groundwater, respectively, also showed a remarkable uniformity in Mo concentrations at each location. Within each, the variability was very small between houses (old and new), between pre-flush and post-flush samples, and between the tap water and respective source water samples. The results indicate that water distribution pipework has a negligible effect on supplied tap water Mo concentrations. The findings contrast with those for Cu, Zn, Ni, Pb, and Cd, which showed significant differences (p < 0.05) in concentrations between pre-flush and post-flush tap water samples. In two pre-flush samples, concentrations of Ni or Pb were above drinking water limits, although in all cases, post-flush waters were compliant. The high concentrations, most likely derived from metal pipework in the domestic distribution system, accumulated during overnight stagnation. The concentrations of Mo observed in British drinking water, in all cases less than 2 μg/l, were more than an order of magnitude below the WHO health-based value and suggest that Mo is unlikely to pose a significant health or water supply problem in England and Wales.
Hanya, Goro; Tsuji, Yamato; Grueter, Cyril C
2013-04-01
In order to understand the ecological adaptations of primates to survive in temperate forests, we need to know the general patterns of plant phenology in temperate and tropical forests. Comparative analyses have been employed to investigate general trends in the seasonality and abundance of fruit and young leaves in tropical and temperate forests. Previous studies have shown that (1) fruit fall biomass in temperate forest is lower than in tropical forest, (2) non-fleshy species, in particular acorns, comprise the majority of the fruit biomass in temperate forest, (3) the duration of the fruiting season is shorter in temperate forest, and (4) the fruiting peak occurs in autumn in most temperate forests. Through our comparative analyses of the fruiting and flushing phenology between Asian temperate and tropical forests, we revealed that (1) fruiting is more annually periodic (the pattern in one year is similar to that seen in the next year) in temperate forest in terms of the number of fruiting species or trees, (2) there is no consistent difference in interannual variations in fruiting between temperate and tropical forests, although some oak-dominated temperate forests exhibit extremely large interannual variations in fruiting, (3) the timing of the flushing peak is predictable (in spring and early summer), and (4) the duration of the flushing season is shorter. The flushing season in temperate forests (17-28 % of that in tropical forests) was quite limited, even compared to the fruiting season (68 %). These results imply that temperate primates need to survive a long period of scarcity of young leaves and fruits, but the timing is predictable. Therefore, a dependence on low-quality foods, such as mature leaves, buds, bark, and lichens, would be indispensable for temperate primates. Due to the high predictability of the timing of fruiting and flushing in temperate forests, fat accumulation during the fruit-abundant period and fat metabolization during the subsequent fruit-scarce period can be an effective strategy to survive the lean period (winter).
Hatje, Vanessa; Attisano, Karina Kammer; de Souza, Marcelo Friederichs Landim; Mazzilli, Barbara; de Oliveira, Joselene; de Araújo Mora, Tamires; Burnett, William C
2017-11-01
Todos os Santos Bay (BTS) is the 2nd largest bay in Brazil and an important resource for the people of the State of Bahia. We made measurements of radon and radium in selected areas of the bay to evaluate if these tracers could provide estimates of submarine groundwater discharge (SGD) and flushing times of the Paraguaçu Estuary and BTS. We found that there were a few areas along the eastern and northeastern shorelines that displayed relatively high radon and low salinities, indicating possible sites of enhanced SGD. A time-series mooring over a tidal cycle at Marina do Bonfim showed a systematic enrichment of the short-lived radium isotopes 223 Ra and 224 Ra during the falling tide. Assuming that the elevated radium isotopes were related to SGD and using measured radium activities from a shallow well at the site, we estimated groundwater seepage at about 70 m 3 /day per unit width of shoreline. Extrapolating to an estimated total shoreline length provided a first approximation of total (fresh + saline) SGD into BTS of 300 m 3 /s, about 3 times the average river discharge into the bay. Just applying the shoreline lengths from areas identified with high radon and reduced salinity results in a lower SGD estimate of 20 m 3 /s. Flushing times of the Paraguaçu Estuary were estimated at about 3-4 days based on changing radium isotope ratios from low to high salinities. The flushing time for the entire BTS was also attempted using the same approach and resulted in a surprisingly low value of only 6-8 days. Although physical oceanographic models have proposed flushing times on the order of months, a simple tidal prism calculation provided results in the range of 4-7 days, consistent with the radium approach. Based on these initial results, we recommend a strategy for refining both SGD and flushing time estimates. Copyright © 2017 Elsevier Ltd. All rights reserved.
The optimal pressure for initial flush with UW solution in heart procurement.
Mohara, Jun; Tsutsumi, Hirofumi; Takeyoshi, Izumi; Tokumine, Masahiko; Aizaki, Masahiro; Ishikawa, Susumu; Matsumoto, Koshi; Morishita, Yasuo
2002-03-01
University of Wisconsin (UW) solution is widely used in organ preservation. Some investigators have reported that high pressure during initial flush with UW solution may induce vasoconstriction and endothelial damage, because of its high potassium content and high viscosity. However, using lower pressure during the initial flush may lead to irregular distribution of the solution and incomplete flushing of blood components from coronary vascular beds. This experimental study evaluated the effects of a range of initial flush pressures during heart procurement, followed by orthotopic transplantation of the graft after 12 hours of preservation. Twelve pairs of adult mongrel dogs, weighing 9 to 14 kg, formed the recipient-donor combinations. After determining hemodynamic status by measuring cardiac output, left ventricular pressure (LVP), and maximum positive and negative change in LVP (+/-LVdP/dt), donor hearts were excised. Coronary vascular beds were flushed with 4 degrees C UW solution at a pressure of 60 mm Hg in the low-pressure group (n = 6) and at 120 mm Hg in the high-pressure group (n = 6). After 12 hours of cold preservation, orthotopic transplantation was performed using cardiopulmonary bypass (CPB). The hemodynamics of the transplanted graft were assessed by comparing recovery rates (%) from donor hearts 2 hours after weaning from CPB. Endothelin-1 (ET-1) levels were measured in the blood obtained from the coronary sinus 30 minutes after reperfusion. The transplanted grafts were then harvested for histologic study and measurement of adenosine triphosphate (ATP) content. Cardiac output, LVP, LVdP/dt and myocardial tissue ATP content were significantly better (p < 0.05) in the high-pressure group than in the low-pressure group. We found no significant differences in ET-1 levels between the groups. Transmission electron microscopic findings revealed that degeneration of the mitochondria was less extensive in the high-pressure group than in the low-pressure group. We observed no obvious ultrastructural damage to the endothelial cells in either group. When using UW solution in heart procurement, high pressure is better to completely wash out the blood components and distribute the solution.
Taylor, Tammy P; Rathfelder, Klaus M; Pennell, Kurt D; Abriola, Linda M
2004-03-01
Alcohol addition has been suggested for use in combination with surfactant flushing to enhance solubilization kinetics and permit density control of dense non-aqueous phase liquid (DNAPL)-laden surfactant plumes. This study examined the effects of adding ethanol (EtOH) to a 4% Tween 80 (polyoxyethylene (20) sorbitan monooleate) solution used to flush tetrachloroethene (PCE)-contaminated porous media. The influence of EtOH concentration, subsurface layering and scale on flushing solution delivery and PCE recovery was investigated through a combination of experimental and mathematical modeling studies. Results of batch experiments demonstrated that the addition of 2.5%, 5% and 10% (wt.) EtOH incrementally increased the PCE solubilization capacity and viscosity of the surfactant solution, while reducing solution density from 1.002 to 0.986 g/cm3. Effluent concentration data obtained from one-dimensional (1-D) column experiments were used to characterize rate-limited micellar solubilization of residual PCE, which was strongly dependent upon flow velocity and weakly dependent upon EtOH concentration. Two-dimensional (2-D) box studies illustrated that minor differences (0.008 g/cm3) between flushing and resident solution density can strongly influence surfactant front propagation. A two-dimensional multiphase simulator, MISER, was used to model the influence of EtOH composition on the aqueous flow field and PCE mass recovery. The ability of the numerical simulator to predict effluent concentrations and front propagation was demonstrated for both 1-D columns and 2-D boxes flushed with EtOH-amended Tween 80 solutions. Results of this study quantify the potential influence of alcohol addition on surfactant solution properties and solubilization capacity, and demonstrate the importance of considering small density variations in remedial design.
Grunfeld, E A; Hunter, M S; Yousaf, O
2017-04-01
Up to 80% of men who receive androgen deprivation therapy report hot flushes and for many these are associated with reduced quality of life. However it is recognised that there are a number of barriers to men's engagement with support to manage symptoms and improve quality of life. This qualitative study was embedded within a larger randomised controlled trial (MANCAN) of a guided self-help cognitive behavioural intervention to manage hot flushes resulting among men receiving androgen deprivation therapy. The study aimed to explore the engagement and experiences with the guided self-help intervention. Twenty men recruited from the treatment arm of the MANCAN trial participated in a semi-structured interview exploring acceptability of the intervention, factors affecting engagement and perceived usefulness of the intervention. Interviews were audio-recorded, transcribed verbatim and analysed using a Framework approach. Over two thirds of respondents (69%) reported reading the intervention booklet in full and over 90% reporting practising the relaxation CD at least once a week. Analysis of the interviews identified three super-ordinate themes and these related to changes in hot flush symptomatology (learned to cope with hot flushes in new ways), the skills that participants had derived from the intervention (promoting relaxation and reducing stressors), and to a broader usefulness of the intervention (broader impact of the intervention and skills). The present study identified positive engagement with a guided self-help intervention and that men applied the skills developed through the intervention to help them undertake general lifestyle changes. Psycho-educational interventions (e.g. cognitive behaviour therapy, relaxation, and positive lifestyle elements) offer the potential to be both effective and well received by male cancer survivors.
MIZUMACHI, ERI; MORI, AKIRA; OSAWA, NAOYA; AKIYAMA, REIKO; TOKUCHI, NAOKO
2006-01-01
• Background and Aims Plants have the ability to compensate for damage caused by herbivores. This is important to plant growth, because a plant cannot always avoid damage, even if it has developed defence mechanisms against herbivores. In previous work, we elucidated the herbivory-induced compensatory response of Quercus (at both the individual shoot and whole sapling levels) in both low- and high-nutrient conditions throughout one growing season. In this study, we determine how the compensatory growth of Quercus serrata saplings is achieved at different nutrient levels. • Methods Quercus serrata saplings were grown under controlled conditions. Length, number of leaves and percentage of leaf area lost on all extension units (EUs) were measured. • Key Results Both the probability of flushing and the length of subsequent EUs significantly increased with an increase in the length of the parent EU. The probability of flushing increased with an increase in leaf damage of the parent EU, but the length of subsequent EUs decreased. This indicates that EU growth is fundamentally regulated at the individual EU level. The probabilities of a second and third flush were significantly higher in plants in high-nutrient soil than those in low-nutrient soil. The subsequent EUs of damaged saplings were also significantly longer at high-nutrient conditions. • Conclusions An increase in the probability of flushes in response to herbivore damage is important for damaged saplings to produce new EUs; further, shortening the length of EUs helps to effectively reproduce foliage lost by herbivory. The probability of flushing also varied according to soil nutrient levels, suggesting that the compensatory growth of individual EUs in response to local damage levels is affected by the nutrients available to the whole sapling. PMID:16709576
The flavonoid luteolin inhibits niacin-induced flush
Papaliodis, D; Boucher, W; Kempuraj, D; Theoharides, T C
2008-01-01
Background and purpose: Sustained release niacin effectively lowers serum cholesterol, LDL and triglycerides, while raising HDL. However, 75% of patients experience cutaneous warmth and itching known as flush, leading to discontinuation. Acetylsalicylic acid (aspirin) reduces this flush only by about 30%, presumably through decreasing prostaglandin D2 (PGD2). We investigated whether niacin-induced flush in a rat model involves PGD2 and 5-HT, and the effect of certain flavonoids. Experimental approach: Three skin temperature measurements from each ear were recorded with an infrared pyrometer for each time point immediately before i.p. injection with either niacin or a flavonoid. The temperature was then measured every 10 min for 60 min. Key results: Niacin (7.5 mg per rat, equivalent to a human dose of 1750 mg per 80 kg) maximally increased ear temperature to 1.9±0.2 oC at 45 min. Quercetin and luteolin (4.3 mg per rat; 1000 mg per human), administered i.p. 45 min prior to niacin, inhibited the niacin effect by 96 and 88%, respectively. Aspirin (1.22 mg per rat; 325 mg per human) inhibited the niacin effect by only 30%. Niacin almost doubled plasma PGD2 and 5-HT, but aspirin reduced only PGD2 by 86%. In contrast, luteolin inhibited both plasma PGD2 and 5-HT levels by 100 and 67%, respectively. Conclusions and implications. Niacin-induced skin temperature increase is associated with PGD2 and 5-HT elevations in rats; luteolin may be a better inhibitor of niacin-induced flush because it blocks the rise in both mediators. PMID:18223672
NASA Astrophysics Data System (ADS)
Hauswirth, Scott C.; Miller, Cass T.
2014-10-01
The remediation of former manufactured gas plant (FMGP) sites contaminated with tar DNAPLs (dense non-aqueous phase liquids) presents a significant challenge. The tars are viscous mixtures of thousands of individual compounds, including known and suspected carcinogens. This work investigates the use of combinations of mobilization, solubilization, and chemical oxidation approaches to remove and degrade tars and tar components in porous medium systems. Column experiments were conducted using several flushing solutions, including an alkaline-polymer (AP) solution containing NaOH and xanthan gum (XG), a surfactant-polymer (SP) solution containing Triton X-100 surfactant (TX100) and XG, an alkaline-surfactant-polymer (ASP) solution containing NaOH, TX100, and XG, and base-activated sodium persulfate both with and without added TX100. The effectiveness of the flushing solutions was assessed based on both removal of polycyclic aromatic hydrocarbon (PAH) mass and on the reduction of dissolved-phase PAH concentrations. SP flushes of 6.6 to 20.9 PV removed over 99% of residual PAH mass and reduced dissolved-phase concentrations by up to two orders of magnitude. ASP flushing efficiently removed 95-96% of residual PAH mass within about 2 PV, and significantly reduced dissolved-phase concentrations of several low molar mass compounds, including naphthalene, acenaphthene, fluorene, and phenanthrene. AP flushing removed a large portion of the residual tar (77%), but was considerably less effective than SP and ASP in terms of the effect on dissolved PAH concentrations. Persulfate was shown to oxidize tar components, primarily those with low molar mass, however, the overall degradation was relatively low (30-50% in columns with low initial tar saturations), and the impact on dissolved-phase concentrations was minimal.
Lindsay, K R; Furlong, M J
2016-08-01
The banana-spotting bug, Amblypelta lutescens lutescens Distant (Hemiptera: Coreidae), is native to Australia and a major polyphagous pest of many tropical and subtropical horticultural crops in the east and north of the country. Different plant structures (flowers, vegetative flush, and different sized fruit) of avocado, lime, and papaya crops and green bean pods (a known suitable host) were evaluated for their suitability as hosts for A. l. lutescens Neonate to imago survivorship, the time taken to complete neonate to imago development, preovipositional period, and fecundity were assessed for each crop. Of all the different phenological stages of the plants investigated, A. l. lutescens could complete development to imago on vegetative flush of papaya and lime, papaya flowers, and green bean pods but on no other structures tested. There was higher survivorship to the second instar when neonates fed on green bean pods or flowers or vegetative flush of avocado, lime, or papaya crops than when neonates fed on small, medium, or large fruit of these crops. Insects that developed to the imago on green bean pods were significantly heavier than insects that developed on papaya flowers or papaya vegetative flush. The mean preoviposition period was shorter, and adult females more fecund, if they completed immature development and then fed as adults on papaya vegetative flush or green beans rather than papaya flowers. The data indicate that avocado is not a suitable host for A. l. lutescens, suggesting that adult populations that cause significant pest damage to the fruit of this crop originate elsewhere. © The Authors 2016. Published by Oxford University Press on behalf of Entomological Society of America. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Modeling of the Inter-phase Mass Transfer during Cosolvent-Enhanced NAPL Remediation
NASA Astrophysics Data System (ADS)
Agaoglu, B.; Scheytt, T. J.; Copty, N. K.
2012-12-01
This study investigates the factors influencing inter-phase mass transfer during cosolvent-enhanced NAPL remediation and the ability of the REV (Representative Elementary Volume) modeling approach to simulate these processes. The NAPLs considered in this study consist of pure toluene, pure benzene and known mixtures of these two compounds, while ethanol-water mixtures were selected as the remedial flushing solutions. Batch tests were performed to identify both the equilibrium and non-equilibrium properties of the multiphase system. A series of column flushing experiments involving different NAPLs were conducted for different ethanol contents in the flushing solution and for different operational parameters. Experimental results were compared to numerical simulations obtained with the UTCHEM multiphase flow simulator (Delshad et al., 1996). Results indicate that the velocity of the flushing solution is a major parameter influencing the inter-phase mass transport processes at the pore scale. Depending on the NAPL composition and porous medium properties, the remedial solution may follow preferential flow paths and be subject to reduced contact with the NAPL. This leads to a steep decrease in the apparent mass transfer coefficient. Correlations of the apparent time-dependent mass transfer coefficient as a function of flushing velocity are developed for various porous media. Experimental results also show that the NAPL mass transfer coefficient into the cosolvent solution increases when the NAPL phase becomes mobile. This is attributed to the increase in pore scale contact area between NAPL and the remedial solution when NAPL mobilization occurs. These results suggest the need to define a temporal and spatially variable mass transfer coefficient of the NAPL into the cosolvent solution to reflect the occurrence of subscale preferential flow paths and the transient bypassing of the NAPL mass. The implications of these findings on field scale NAPL remediation with cosolvents are discussed.
Recent sheath physics studies on DIII-D
NASA Astrophysics Data System (ADS)
Watkins, J. G.; Labombard, B.; Stangeby, P. C.; Lasnier, C. J.; McLean, A. G.; Nygren, R. E.; Boedo, J. A.; Leonard, A. W.; Rudakov, D. L.
2015-08-01
A study to examine some current issues in the physics of the plasma sheath has been recently carried out in DIII-D low power Ohmic plasmas using both flush and domed Langmuir probes, divertor Thomson scattering (DTS), an infrared camera (IRTV), and a new calorimeter triple probe assembly mounted on the Divertor Materials Evaluation System (DIMES). The sheath power transmission factor was found to be consistent with the theoretically predicted value of 7 (±2) for low power plasmas. Using this factor, the three heat flux profiles derived from the LP, DTS, and calorimeter diagnostic measurements agree. Comparison of flush and domed Langmuir probes and divertor Thomson scattering indicates that proper interpretation of flush probe data to get target plate density and temperature is feasible and could potentially yield accurate measurements of target plate conditions where the probes are located.
CAD and CAE Analysis for Siphon Jet Toilet
NASA Astrophysics Data System (ADS)
Wang, Yuhua; Xiu, Guoji; Tan, Haishu
The high precision 3D laser scanner with the dual CCD technology was used to measure the original design sample of a siphon jet toilet. The digital toilet model was constructed from the cloud data measured with the curve and surface fitting technology and the CAD/CAE systems. The Realizable k - ɛ double equation model of the turbulence viscosity coefficient method and the VOF multiphase flow model were used to simulate the flushing flow in the toilet digital model. Through simulating and analyzing the distribution of the flushing flow's total pressure, the flow speed at the toilet-basin surface and the siphoning bent tube, the toilet performance can be evaluated efficiently and conveniently. The method of "establishing digital model, flushing flow simulating, performances evaluating, function shape modifying" would provide a high efficiency approach to develop new water-saving toilets.
Real-time electronic monitoring of a pitted and leaking gas gathering pipeline
DOE Office of Scientific and Technical Information (OSTI.GOV)
Asperger, R.G.; Hewitt, P.G.
1986-08-01
Hydrogen patch, flush electrical resistance, and flush linear polarization proves wre used with flush coupons to monitor corrosion rates in a pitted and leaking sour gas gathering line. Four inhibitors were evaluated in stopping the leaks. Inhibitor residuals and the amount and ratio of water and condensate in the lines were measured at five locations along the line. The best inhibitor reduced reduced the pit-leak frequency by over a factor of 10. Inhibitor usage rate was optimized using the hydrogen patch current as a measure of the instantaneous corrosion rate. Improper pigging was identified as a cause of corrosion transients.more » This problem is discussed in relation to the pigging of pipelines in stratified flow where moving fluids are the carriers for continuously injected corrosion inhibitors.« less
Growth and structure of In{sub 0.5}Ga{sub 0.5}Sb quantum dots on GaP(001)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sala, E. M.; Stracke, G.; Schlichting, S.
2016-09-05
Stranski-Krastanov (SK) growth of In{sub 0.5}Ga{sub 0.5}Sb quantum dots (QDs) on GaP(001) by metalorganic vapor phase epitaxy is demonstrated. A thin GaAs interlayer prior to QD deposition enables QD nucleation. The impact of a short Sb-flush before supplying InGaSb is investigated. QD growth gets partially suppressed for GaAs interlayer thicknesses below 6 monolayers. QD densities vary from 5 × 10{sup 9} to 2 × 10{sup 11} cm{sup −2} depending on material deposition and Sb-flush time. When In{sub 0.5}Ga{sub 0.5}Sb growth is carried out without Sb-flush, the QD density is generally decreased, and up to 60% larger QDs are obtained.
Real-time control of combined surface water quantity and quality: polder flushing.
Xu, M; van Overloop, P J; van de Giesen, N C; Stelling, G S
2010-01-01
In open water systems, keeping both water depths and water quality at specified values is critical for maintaining a 'healthy' water system. Many systems still require manual operation, at least for water quality management. When applying real-time control, both quantity and quality standards need to be met. In this paper, an artificial polder flushing case is studied. Model Predictive Control (MPC) is developed to control the system. In addition to MPC, a 'forward estimation' procedure is used to acquire water quality predictions for the simplified model used in MPC optimization. In order to illustrate the advantages of MPC, classical control [Proportional-Integral control (PI)] has been developed for comparison in the test case. The results show that both algorithms are able to control the polder flushing process, but MPC is more efficient in functionality and control flexibility.
Impact of Lupinus leucophyllous on the nitrogen budgets of semi-arid plant communities
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hinds, W.T.; Hinds, N.R.
1982-10-01
In the semi-arid grassland on the Arid Lands Ecology Reserve on the Hanford Site in south-central Washington State, three legume flushes occurred in the past decade. Estimates of leguminous nitrogen in both native and disturbed vegetation after a flush showed that nitrogen in the legume (above-ground) doubled the amount of nitrogen associated with vascular plant tissues. 21 references, 2 tables.
O'Toole, J; Keywood, M; Sinclair, M; Leder, K
2009-01-01
The aim of this study was to address existing data gaps and to determine the size distribution of aerosols associated with water-efficient devices during typical domestic activities. This information is important to assist in understanding infection spread during water-using activities and in designing water regulations. Three water-using scenarios were evaluated: i) showering using a water-efficient showerhead; ii) use of a high pressure spray unit for cleaning cars and iii) toilet flushing using a dual flush low volume flush device. For each scenario a control condition (conventional lower efficiency device) was selected for benchmarking purposes. Shower module results highlighted the complexity of particle generation and removal processes and showed that more than 90% of total particle mass in the breathing zone was attributed to particle diameters greater than 6 mum. Conversely, results for car washing experiments showed that particle diameters up to 6 mum constituted the major part of the total mass generated by both water-efficient and conventional devices. Even under worse case scenario conditions for toilet flushing, particle measurements were at or below the level of detection of the measuring instrumentation. The data provide information that assists in health risk assessment and in determining future research directions, including methodological aspects.
Flores-Ramos, Mónica; Heinze, Gerhard; Silvestri-Tomassoni, Roberto
2010-02-01
The aim of this study was to explore the association between depressive symptoms and some variables related to the reproductive life, such as history of premenstrual dysphoric disorder, antecedent of postpartum depression, previous use of hormonal contraceptives, and current hot flushes, in a group of perimenopausal women attending a menopause clinic. Perimenopausal women, 45 to 55 years old, who had not received hormonal replacement therapy and/or psychotropic medication, were invited to participate in this study. 141 perimenopausal women were included; we obtained their psychiatric and gynecological data, and we evaluated their depressive symptomatology using the CES-D scale. There were a significantly higher number of cases of previous depressive episodes, PMDD and PPD history in depressed patients compared with non-depressed women; current hot flushes prevalence was similar between depressed and non-depressed women. Patients with a PMDD history were more likely to have experienced previous depressive episodes, a PPD history and high levels of depression. Variables associated with the level of depression were a previous history of PMDD, current hot flushes, and previous depressive episodes. The occurrence of perimenopausal depression is related to a previous history of PMDD, PPD, and depressive episodes; hot flushes only increase the severity of the depressive episode.
Kock, Niels B; Van Susante, Job L C; Buma, Pieter; Van Kampen, Albert; Verdonschot, Nico
2006-06-01
Osteochondral autologous transplantation is used for the treatment of full-thickness articular cartilage lesions of a joint. Press-fit stability is an important factor for good survival of the transplanted plugs. 36 plugs of three different lengths were transplanted in fresh-frozen human knees. On one condyle, 3 plugs were exactly matched to the depth of the recipient site ("bottomed" plugs) and on the opposite condyle 3 plugs were 5 mm shorter than the depth of the recipient site ("unbottomed" plugs). Plugs were left protruding and then pushed in until flush, and then to 2 mm below flush level, using a loading apparatus. Longer plugs needed higher forces to begin displacement. At flush level, bottomed plugs needed significantly higher forces than unbottomed plugs to become displaced below flush level (mean forces of 404 N and 131 N, respectively). Shorter bottomed plugs required higher forces than longer bottomed ones. Bottomed plugs generally provide much more stability than unbottomed ones. Short bottomed plugs are more stable than long bottomed plugs. Thus, in clinical practice it is advisable to use short bottomed plugs. If, however, unbottomed plugs are still chosen, the longer the plug the higher the resulting stability will be because of higher frictional forces.
Uncovering the abilities of Agaricus bisporus to degrade plant biomass throughout its life cycle.
Patyshakuliyeva, Aleksandrina; Post, Harm; Zhou, Miaomiao; Jurak, Edita; Heck, Albert J R; Hildén, Kristiina S; Kabel, Mirjam A; Mäkelä, Miia R; Altelaar, Maarten A F; de Vries, Ronald P
2015-08-01
The economically important edible basidiomycete mushroom Agaricus bisporus thrives on decaying plant material in forests and grasslands of North America and Europe. It degrades forest litter and contributes to global carbon recycling, depolymerizing (hemi-)cellulose and lignin in plant biomass. Relatively little is known about how A. bisporus grows in the controlled environment in commercial production facilities and utilizes its substrate. Using transcriptomics and proteomics, we showed that changes in plant biomass degradation by A. bisporus occur throughout its life cycle. Ligninolytic genes were only highly expressed during the spawning stage day 16. In contrast, (hemi-)cellulolytic genes were highly expressed at the first flush, whereas low expression was observed at the second flush. The essential role for many highly expressed plant biomass degrading genes was supported by exo-proteome analysis. Our data also support a model of sequential lignocellulose degradation by wood-decaying fungi proposed in previous studies, concluding that lignin is degraded at the initial stage of growth in compost and is not modified after the spawning stage. The observed differences in gene expression involved in (hemi-)cellulose degradation between the first and second flushes could partially explain the reduction in the number of mushrooms during the second flush. © 2015 Society for Applied Microbiology and John Wiley & Sons Ltd.
NASA Astrophysics Data System (ADS)
Tang, Samuel C. N.; Yin, Ke; Lo, Irene M. C.
2011-07-01
Column experiments were conducted for examining the effectiveness of the cationic hydrogel on Cr(VI) removal from groundwater and soil. For in-situ groundwater remediation, the effects of background anions, humic acid (HA) and pH were studied. Cr(VI) has a higher preference for being adsorbed onto the cationic hydrogel than sulphate, bicarbonate ions and HA. However, the adsorbed HA reduced the Cr(VI) removal capacity of the cationic hydrogel, especially after regeneration of the adsorbents, probably due to the blockage of adsorption sites. The Cr(VI) removal was slightly influenced by the groundwater pH that could be attributed to Cr(VI) speciation. The 6-cycle regeneration and reusability study shows that the effectiveness of the cationic hydrogel remained almost unchanged. On average, 93% of the adsorbed Cr(VI) was recovered in each cycle and concentrated Cr(VI) solution was obtained after regeneration. For in-situ soil remediation, the flushing water pH had an insignificant effect on the release of Cr(VI) from the soils. Multiple-pulse flushing increased the removal of Cr(VI) from the soils. In contrast, more flushing water and longer operation may be required to achieve the same removal level by continuous flushing.
Li, Yuanqing; Zhu, Xiaoshu; Bensussan, Alan; Li, Pingping; Moylan, Eugene; Delaney, Geoff; McPherson, Luke
2016-01-01
Objective. This systematic review was conducted to evaluate the clinical effectiveness and safety of herbal medicine (HM) as an alternative management for hot flushes induced by endocrine therapy in breast cancer patients. Methods. Key English and Chinese language databases were searched from inception to July 2015. Randomized Controlled Trials (RCTs) evaluating the effects of HM on hot flushes induced by endocrine therapy in women with breast cancer were retrieved. We conducted data collection and analysis in accordance with the Cochrane Handbook for Systematic Reviews of Interventions. Statistical analysis was performed with the software (Review Manager 5.3). Results. 19 articles were selected from the articles retrieved, and 5 articles met the inclusion criteria for analysis. Some included individual studies showed that HM can relieve hot flushes as well as other menopausal symptoms induced by endocrine therapy among women with breast cancer and improve the quality of life. There are minor side effects related to HM which are well tolerated. Conclusion. Given the small number of included studies and relatively poor methodological quality, there is insufficient evidence to draw positive conclusions regarding the objective benefit of HM. Additional high quality studies are needed with more rigorous methodological approach to answer this question.
Transport models for desorption from natural soils packed in flushed columns
NASA Astrophysics Data System (ADS)
Brouwers, H. J. H.
1999-06-01
This paper addresses an experimental and theoretical study of sorbed contaminant removal from a column (or reactor) by flushing. This removal may take place by either volatilization or rinsing, and nonlinear sorption is accounted for by employing a Freundlich relationship. A one-dimensional nonequilibrium transport model is proposed which describes the unsteady mass transfer between flushing medium and soil phases in the column, using a linear chemical transfer model. The moving boundary problem is transferred, and a perturbation method is employed to obtain an approximate solution of the governing equations for a small Merkel number Me (this dimensionless number comprises the product of fluid residence time and the mass transfer coefficient). The solution reveals the effect of the various parameters, such as the Freundlich parameter n, on the contaminant transport in fluid phase and decay in solid phase. Applying the model to various experimental data results in values for the overall mass transfer coefficients, which are useful for engineering computations. Furthermore, the model enables the prediction of the initial soil contamination level as well as the parameter n solely from the measured exit contaminant concentrations in the flushing fluid. A thorough comparison of this prediction with the measured soil concentration (prior to the experiments) yields good agreement.
NASA Astrophysics Data System (ADS)
Nash, S.; O'Brien, N.; Olbert, A.; Hartnett, M.
2014-10-01
The introduction of tidal stream turbines into water bodies can have an impact on the environment due to changes in the hydrodynamic flow fields resulting from the extraction of energy by the tidal turbines. Water levels, tidal currents and flushing characteristics could potentially be significantly altered with the introduction of tidal turbine farms, which could lead to possible loss of habitat and a change in the tidal regime. Therefore, planning of tidal turbines field deployments must take into account possible hydro-environmental impacts. This paper describes research undertaken by the authors in the Shannon Estuary to predict changes in the tidal regime and flushing characteristics, with the introduction of tidal turbine farms of different array configurations. The model was simulated using a 2D hydrodynamic model that was modified to incorporate the effects of tidal turbine fields. Water levels are shown to have been affected with the inclusion of turbines, especially in areas upstream of the turbine farm where inter-tidal zones could become predominately inundated resulting in loss of habitat in the estuary. Flushing parameters were also shown to be altered with the inclusion of turbines, with residence time shown to be increased, which could change pollutant transport in the region.
USDA-ARS?s Scientific Manuscript database
A six-month trial was conducted to compare the effects of high and low make-up water flushing rates on rainbow trout performance and water quality in replicated water reuse aquaculture systems (WRAS). Six identical 9.5 m3 WRAS, containing a single 5.3 m3 tank and operated at a total recirculating fl...
Operator’s Manual for UH-60A Helicopter, UH-60L Helicopter, EH-60A Helicopter
1996-10-31
electrolyte is harmful to the skin and clothing. If potassium hydroxide is spilled on clothing or other material, wash immediately with clean water . If spilled...on personnel, immediately flush the affected area with clean water . Continue washing until medical assistance arrives. Neutralize any spilled...electrolyte by thoroughly flushing contacted area with water . CARBON MONOXIDE When smoke, suspected carbon monoxide fumes, or symptoms of anoxia exist, the
Flushing associated with scombroid fish poisoning.
Ferran, Marta; Yébenes, Mireia
2006-10-31
Scombroid poisoning is a form of toxicity caused by the ingestion of spoiled dark-flesh fishes, mainly of the scombroid family. The clinical picture is secondary to histamine toxicity, manifested as flushing, headache, palpitations, and abdominal cramps. The diagnosis is established on the basis of these typical clinical manifestations and fish-ingestion history. We report a case of a man with scombroid poisoning. He was diagnosed after presentation of two similar patients with the same epidemiological history.
1951-10-24
Flight evaluation and comparison of a NACA submerged inlet and a scoop inlet on the North American YF-93A (AF48-317 NACA-139). The YF-93A's were the first aircraft to use flush NACA engine inlets. aircraft to use flush NACA engine inlets. Note: Used in publication in Flight Research at Ames; 57 Years of Development and Validation of Aeronautical Technology NASA SP-1998-3300 and Memoirs of a Flight Test Engineer NASA SP-2001-4525
Potential of nitrogen gas (n2) flushing to extend the shelf life of cold stored pasteurised milk.
Munsch-Alatossava, Patricia; Ghafar, Abdul; Alatossava, Tapani
2013-03-11
For different reasons, the amount of food loss for developing and developed countries is approximately equivalent. Altogether, these losses represent approximately 1/3 of the global food production. Significant amounts of pasteurised milk are lost due to bad smell and unpleasant taste. Currently, even under the best cold chain conditions, psychrotolerant spore-forming bacteria, some of which also harbour virulent factors, limit the shelf life of pasteurised milk. N2 gas-based flushing has recently been of interest for improving the quality of raw milk. Here, we evaluated the possibility of addressing bacterial growth in pasteurised milk during cold storage at 6 °C and 8 °C. Clearly, the treatments hindered bacterial growth, in a laboratory setting, when N2-treated milk were compared to the corresponding controls, which suggests that N2-flushing treatment constitutes a promising option to extend the shelf life of pasteurised milk.
Variation in PAH patterns in road runoff.
Aryal, Rupak; Furumai, Hiroaki; Nakajima, Fumiyuki; Beecham, Simon
2013-01-01
Twelve particle-bound polycyclic aromatic hydrocarbons (PAHs) were measured in the first flush regime of road runoff during nine events in Winterthur in Switzerland. The total PAH contents ranged from 17 to 62 μg/g. The PAH patterns measured at different time intervals during the first flush periods were very similar within each event irrespective of variation in suspended solids (SS) concentration within the first flush regime. However, the PAH patterns were different from event to event. This indicates that the environment plays an important role in PAH accumulation in SS. A toxicity identification evaluation approach using a toxicity equivalency factor (TEF) was applied to compare toxicities in the different events. The TEFs were found to be between 8 and 33 μg TEQ g(-1) (TEQ: toxic equivalent concentration). In some cases, two events having similar total PAH contents showed two fold toxicity differences.
Potential of Nitrogen Gas (N2) Flushing to Extend the Shelf Life of Cold Stored Pasteurised Milk
Munsch-Alatossava, Patricia; Ghafar, Abdul; Alatossava, Tapani
2013-01-01
For different reasons, the amount of food loss for developing and developed countries is approximately equivalent. Altogether, these losses represent approximately 1/3 of the global food production. Significant amounts of pasteurised milk are lost due to bad smell and unpleasant taste. Currently, even under the best cold chain conditions, psychrotolerant spore-forming bacteria, some of which also harbour virulent factors, limit the shelf life of pasteurised milk. N2 gas-based flushing has recently been of interest for improving the quality of raw milk. Here, we evaluated the possibility of addressing bacterial growth in pasteurised milk during cold storage at 6 °C and 8 °C. Clearly, the treatments hindered bacterial growth, in a laboratory setting, when N2-treated milk were compared to the corresponding controls, which suggests that N2-flushing treatment constitutes a promising option to extend the shelf life of pasteurised milk. PMID:23478439
Extensive Treatment System For Recycling Water For Flushing Fresh Manure And Recovering Nutrients
NASA Astrophysics Data System (ADS)
Morand, Philippe; Robin, Paul; Escande, Aurélie; Picot, Bernadette; Pourcher, Anne-Marie; Jiangping, Qiu; Yinsheng, Li; Hamon, Gwenn; Amblard, Charlotte; Luth, Fievet, Sébastien; Oudart, Didier; Le Quéré, Camille Pain; Cluzeau, Daniel; Landrain, Brigitte
2010-11-01
From preliminary researches on a pilot scale, a complete demonstration plant was built to treat the effluents of a 30 pregnant sow's piggery. It includes a screen, a vermifilter, a macrophyte lagooning, and a complementary water storage pond; the recycled water is used for flushing, and rainfall is collected to compensate for evapotranspiration. After functioning in 2008 and 2009, it was showed that, during the warm season, the whole plant produced an effluent suitable for flushing, where the concentration decrease was over 70% for the phosphorus and potassium, 95% for the COD and nitrogen, 99.8% for endocrine disruptors (estrogenic activity), and 99.99% for pathogenic micro-organisms. During the cold season, the dilution by the rain water and the treatment effect of the constructed wetlands lead to similar results. Nevertheless, for this season, suitable floating macrophytes that will cover the lagoons remain to be settled.
Yokoyama, A; Muramatsu, T; Omori, T; Matsushita, S; Yoshimizu, H; Higuchi, S; Yokoyama, T; Maruyama, K; Ishii, H
1999-11-01
Studies have consistently demonstrated that inactive aldehyde dehydrogenase-2 (ALDH2), encoded by ALDH2*1/2*2, is closely associated with alcohol-related carcinogenesis. Recently, the contributions of alcohol dehydrogenase-2 (ADH2) polymorphism to alcoholism, esophageal cancer, and the flushing response have also been described. To determine the effects of ALDH2 and ADH2 genotypes in genetically based cancer susceptibility, lymphocyte DNA samples from 668 Japanese alcoholic men more than 40 years of age (91 with and 577 without esophageal cancer) were genotyped and the results were expressed as odds ratios (ORs). This study also tested 82 of the alcoholics with esophageal cancer to determine whether cancer susceptibility is associated with patients' responses to simple questions about current or former flushing after drinking a glass of beer. The frequencies of ADH2*1/2*1 and ALDH2*1/2*2 were significantly higher in alcoholics with, than in those without, esophageal cancer (0.473 vs. 0.289 and 0.560 vs. 0.099, respectively). After adjustment for drinking and smoking, the analysis showed significantly increased cancer risk for alcoholics with either ADH2*1/2*I (OR = 2.03) or ALDH2*1/2*2 (OR = 12.76). For those having ADH2*1/2*1 combined with ALDH2*1/2*2, the esophageal cancer risk was enhanced in a multiplicative fashion (OR = 27.66). Responses to flushing questions showed that only 47.8% of the ALDH2*1/2*2 heterozygotes with ADH2*1/ 2*1, compared with 92.3% of those with ALDH2*1/2*2 and the ADH2*2 allele, reported current or former flushing. Genotyping showed that for alcoholics who reported ever flushing, the questionnaire was 71.4% correct in identifying ALDH2*1/2*2 and 87.9% correct in identifying ALDH2*1/2*1. Japanese alcoholics can be divided into cancer susceptibility groups on the basis of their combined ADH2 and ALDH2 genotypes. The flushing questionnaire can predict high risk ALDH2*1/2*2 fairly accurately in persons with ADH2*2 allele, but a reliable screening procedure for the highest risk gene combination (ADH2*1/2*1 and ALDH2*1/2*2) will require further investigation.
Salilew-Wondim, Dessie; Saeed-Zidane, Mohammed; Hoelker, Michael; Gebremedhn, Samuel; Poirier, Mikhaël; Pandey, Hari Om; Tholen, Ernst; Neuhoff, Christiane; Held, Eva; Besenfelder, Urban; Havlicek, Vita; Rings, Franca; Fournier, Eric; Gagné, Dominic; Sirard, Marc-André; Robert, Claude; Gad, Ahmed; Schellander, Karl; Tesfaye, Dawit
2018-06-01
Aberrant DNA methylation patterns of genes required for development are common in in vitro produced embryos. In this regard, we previously identified altered DNA methylation patterns of in vivo developed blastocysts from embryos which spent different stages of development in vitro, indicating carryover effects of suboptimal culture conditions on epigenetic signatures of preimplantation embryos. However, epigenetic responses of in vivo originated embryos to suboptimal culture conditions are not fully understood. Therefore, here we investigated DNA methylation patterns of in vivo derived bovine embryos subjected to in vitro culture condition before, during or after major embryonic genome activation (EGA). For this, in vivo produced 2-, 8- and 16-cell stage embryos were cultured in vitro until the blastocyst stage and blastocysts were used for genome-wide DNA methylation analysis. The 2- and 8-cell flushed embryo groups showed lower blastocyst rates compared to the 16-cell flush group. This was further accompanied by increased numbers of differentially methylated genomic regions (DMRs) in blastocysts of the 2- and 8-cell flush groups compared to the complete in vivo control ones. Moreover, 1623 genomic loci including imprinted genes were hypermethylated in blastocyst of 2-, 8- and 16-cell flushed groups, indicating the presence of genomic regions which are sensitive to the in vitro culture at any stage of embryonic development. Furthermore, hypermethylated genomic loci outnumbered hypomethylated ones in blastocysts of 2- and 16-cell flushed embryo groups, but the opposite occurred in the 8-cell group. Moreover, DMRs which were unique to blastocysts of the 2-cell flushed group and inversely correlated with corresponding mRNA expression levels were involved in plasma membrane lactate transport, amino acid transport and phosphorus metabolic processes, whereas DMRs which were specific to the 8-cell group and inversely correlated with corresponding mRNA expression levels were involved in several biological processes including regulation of fatty acids and steroid biosynthesis processes. In vivo embryos subjected to in vitro culture before and during major embryonic genome activation (EGA) are prone to changes in DNA methylation marks and exposure of in vivo embryos to in vitro culture during the time of EGA increased hypomethylated genomic loci in blastocysts.
Lyons, Margaret G; Phalen, Ann G
2014-01-01
Research has failed to demonstrate an optimal flushing solution or frequency for central catheters. In a 2002 study of 50 000 home care patients, catheter dysfunction with loss of patency was the most common complication and occurred in 29% of the peripherally inserted central catheters (PICCs) tracked. With the advent of the Affordable Care Act and the promise of expanded home care services, this study offers evidence as to a preferred flushing protocol to prevent catheter patency complications for home infusion patients with PICCs. This prospective, randomized, 1-way, single-blinded posttest with control group study was performed to compare 3 commonly used flushing protocols in home infusion patients with PICCs. The independent variable was the flushing protocol, and dependent variables included the development of patency-related complications and other significant issues such as sluggishness, occlusion, missed medication doses, catheter replacement, additional nursing visits, and the use of alteplase (Cathflo Activase). Each of the study groups had patients who experienced 1 or more patency-related complications. Additional factors that may affect catheter function, including patient age, gender, diagnosis, therapy type, frequency of catheter use, catheter brand/size/number of lumens, concomitant use of anticoagulant medications, and whether PICCs were used for routine lab testing, were analyzed, and no statistical significance was determined. Catheter dwell time (catheter days) was statistically significant (p = .003, confidence interval = 95%; assuming equal variance) and confirmed the assumption that the longer a home care patient's catheter was in place, the more complications occurred. There were no cases of heparin allergy, heparin-induced thrombocytopenia, or line infection. The data provide some evidence to support the elimination of heparin flushing in home care patients with PICCs, although data in the saline-only group that related to additional registered nurse visits to assess PICC patency and the use of alteplase (Cathflo Activase) were trending toward significance because this group experienced a higher incidence of these complications than both the heparin groups. These findings should not be translated to home care patients with cancer or pregnancy diagnoses because these populations were excluded from this study. More studies of this topic area should be initiated. Please see video abstract, Supplemental Digital Content 1, for more information (http://links.lww.com/JIN/A3).
Khan, Usman; Bloom, Raanan A; Nicell, James A; Laurenson, James P
2017-12-31
A select few prescription drugs can be especially harmful and, in some cases, fatal with just one dose when not used as prescribed. Therefore, the U. S. Food and Drug Administration (FDA) recommends that expired, unwanted, or otherwise unused portions of most of these drugs be disposed of quickly through a take-back program. If such an option is not readily available, FDA recommends that they be flushed down the sink or toilet. The goal of the current investigation was to evaluate the ecological and human-health risks associated with the environmental release of the 15 active pharmaceutical ingredients (APIs) currently on the FDA "flush list". The evaluation suggests that even when highly conservative assumptions are used-including that the entire API mass supplied for clinical use is flushed, all relevant sources in addition to clinical use of the API are considered, and no metabolic loss, environmental degradation, or dilution of wastewater effluents are used in estimating environmental concentrations-most of these APIs present a negligible eco-toxicological risk, both as individual compounds and as a mixture. For a few of these APIs, additional eco-toxicological data will need to be developed. Using similar conservative assumptions for human-health risks, all 15 APIs present negligible risk through ingestion of water and fish. Published by Elsevier B.V.
Temperature dynamics of stormwater runoff in Australia and the USA.
Hathaway, J M; Winston, R J; Brown, R A; Hunt, W F; McCarthy, D T
2016-07-15
Thermal pollution of surface waters by urban stormwater runoff is an often overlooked by-product of urbanization. Elevated stream temperatures due to an influx of stormwater runoff can be detrimental to stream biota, in particular for cold water systems. However, few studies have examined temperature trends throughout storm events to determine how these thermal inputs are temporally distributed. In this study, six diverse catchments in two continents are evaluated for thermal dynamics. Summary statistics from the data showed larger catchments have lower maximum runoff temperatures, minimum runoff temperatures, and temperature variability. This reinforces the understanding that subsurface drainage infrastructure in urban catchments acts to moderate runoff temperatures. The catchments were also evaluated for the presence of a thermal first flush using two methodologies. Results showed the lack of a first flush under traditional assessment methodologies across all six catchments, supporting the results from a limited number of studies in literature. However, the time to peak temperature was not always coincident with the time to peak flow, highlighting the variability of thermal load over time. When a new first flush methodology was applied, significant differences in temperature were noted with increasing runoff depth for five of the six sites. This study is the first to identify a runoff temperature first flush, and highlights the need to carefully consider the appropriate methodology for such analyses. Copyright © 2016 Elsevier B.V. All rights reserved.
Asian flushing: genetic and sociocultural factors of alcoholism among East asians.
Lee, Haeok; Kim, Sun S; You, Kwang Soo; Park, Wanju; Yang, Jin Hyang; Kim, Minjin; Hayman, Laura L
2014-01-01
Alcohol use can lead to a cascade of problems such as increased chances of risky behavior and negative health consequences, including alcoholic liver disease and upper gastric and liver cancer. Ethanol is metabolized mainly by 2 major enzymes: alcohol dehydrogenase (ADH) and acetaldehyde dehydrogenase (ALDH). Genetic variations of genes encoding the 2 enzymes are very common among East Asians but relatively rare for most other populations. Facial flushing and other physical discomforts after alcohol drinking triggered by accumulation of acetaldehyde through defective genes for ADH and ALDH have been reported. Approximately 40% of East Asians (Chinese, Japanese, and Korean) show facial flushing after drinking alcohol, known as "Asian flush," which is characterized by adverse reactions on alcohol drinking in individuals possessing the fasting metabolizing alleles for ADH, ADH1B*2, and ADH1C*1, and the null allele for ALDH and ALDH2*2. Alcoholism is determined not only by the genetic deficiency but also by behaviors that involve complex interactions between genetic and sociocultural factors. The purpose of this article was to provide nurses with the most current information about genetic and sociocultural influences on alcoholism and alcohol-related health problems specifically for East Asians and implications of this knowledge to nursing practice. The physiological phenomenon of genes and genetics in relation to alcohol metabolism in this special population is emphasized.
van de Wetering, M D; van Woensel, J B M; Kremer, L C M; Caron, H N
2005-05-01
Long-term tunnelled central venous catheters (TCVC) are increasingly used in oncology patients. Infections are a frequent complication of TCVC, mostly caused by Gram-positive bacteria. The objective of this review is to evaluate the efficacy of antibiotics in the prevention of early Gram-positive TCVC infections, in oncology patients. We searched MEDLINE, EMBASE, and the Cochrane Controlled Trials Register up to July 2003. We selected randomised controlled trials (RCT) evaluating prophylactic antibiotics prior to insertion of the TCVC, and the combination of an antibiotic and heparin to flush the TCVC, in paediatric and adult oncology patients. The primary outcome was documented Gram-positive bacteraemia in patients with a TCVC. All trials identified were assessed and the data extracted independently by two reviewers. There were nine trials included. Four trials reported on vancomycin/teicoplanin prior to insertion of the TCVC compared to no antibiotics. There was no reduction in the number of Gram-positive TCVC infections with an Odds ratio of 0.42 (95% confidence interval 0.13-1.31). Five trials studied flushing of the TCVC with a vancomycin/heparin solution compared to heparin flushing only. This method decreased the number of TCVC infections significantly with an Odds ratio of 0.43 (95% CI 0.21-0.87). Flushing the TCVC with a vancomycin/heparin solution reduced the incidence of Gram-positive infections.
Multi-purpose rainwater harvesting for water resource recovery and the cooling effect.
An, Kyoung Jin; Lam, Yun Fat; Hao, Song; Morakinyo, Tobi Eniolu; Furumai, Hiroaki
2015-12-01
The potential use of rainwater harvesting in conjunction with miscellaneous water supplies and a rooftop garden with rainwater harvesting facility for temperature reduction have been evaluated in this study for Hong Kong. Various water applications such as toilet flushing and areal climate controls have been systematically considered depending on the availability of seawater toilet flushing using the Geographic Information System (GIS). For water supplies, the district Area Precipitation per Demand Ratio (APDR) has been calculated to quantify the rainwater utilization potential of each administrative district in Hong Kong. Districts with freshwater toilet flushing prove to have higher potential for rainwater harvest and utilization compared to the areas with seawater toilet flushing. Furthermore, the effectiveness of using rainwater harvesting for miscellaneous water supplies in Hong Kong and Tokyo has been analyzed and compared; this revives serious consideration of diurnal and seasonal patterns of rainfall in applying such technology. In terms of the cooling effect, the implementation of a rooftop rainwater harvesting garden has been evaluated using the ENVI-met model. Our results show that a temperature drop of 1.3 °C has been observed due to the rainwater layer in the rain garden. This study provides valuable insight into the applicability of the rainwater harvesting for sustainable water management practice in a highly urbanized city. Copyright © 2015 Elsevier Ltd. All rights reserved.
Modeling nitrate-nitrogen removal process in first-flush reactor for stormwater treatment.
Deng, Zhiqiang; Sun, Shaowei; Gang, Daniel Dianchen
2012-08-01
Stormwater runoff is one of the most common non-point sources of water pollution to rivers, lakes, estuaries, and coastal beaches. While most pollutants and nutrients, including nitrate-nitrogen, in stormwater are discharged into receiving waters during the first-flush period, no existing best management practices (BMPs) are specifically designed to capture and treat the first-flush portion of urban stormwater runoff. This paper presents a novel BMP device for highway and urban stormwater treatment with emphasis on numerical modeling of the new BMP, called first-flush reactor (FFR). A new model, called VART-DN model, for simulation of denitrification process in the designed first-flush reactor was developed using the variable residence time (VART) model. The VART-DN model is capable of simulating various processes and mechanisms responsible for denitrification in the FFR. Based on sensitivity analysis results of model parameters, the denitrification process is sensitive to the temperature correction factor (b), maximum nitrate-nitrogen decay rate (K (max)), actual varying residence time (T (v)), the constant decay rate of denitrifiying bacteria (v (dec)), temperature (T), biomass inhibition constant (K (b)), maximum growth rate of denitrifiying bacteria (v (max)), denitrifying bacteria concentration (X), longitudinal dispersion coefficient (K (s)), and half-saturation constant of dissolved carbon for biomass (K (Car-X)); a 10% increase in the model parameter values causes a change in model root mean square error (RMSE) of -28.02, -16.16, -12.35, 11.44, -9.68, 10.61, -16.30, -9.27, 6.58 and 3.89%, respectively. The VART-DN model was tested using the data from laboratory experiments conducted using highway stormwater and secondary wastewater. Model results for the denitrification process of highway stormwater showed a good agreement with observed data and the simulation error was less than 9.0%. The RMSE and the coefficient of determination for simulating denitrification process of wastewater were 0.5167 and 0.6912, respectively, demonstrating the efficacy of the VART-DN model.
Myers, S P; Vigar, V
2017-01-15
To critically assess the evidence for a specific standardised extract of Trifolium pratense isoflavones (Promensil) at a dosage of 80mg/day in the treatment of menopausal hot flushes. Systematic literature searches were performed in Medline, Scopus, CINAHL Plus, Cochrane, AMED and InforRMIT and citations obtained from 1996 to March 2016. Reference lists were checked; corresponding authors contacted and the grey literature searched for additional publications. Studies were selected according to predefined inclusion and exclusion criteria. All randomised clinical trials of a specific standardised extract of Trifolium pratense isoflavones (Promensil) used as a mono-component at 80mg/day and measuring vasomotor symptoms were included. The data extraction and quality assessment were performed independently by one reviewer and validated by a second with any disagreements being settled by discussion. Weighted mean differences and 95% confidence intervals were calculated for continuous data using the fixed-effects model. Twenty potentially relevant papers were identified, with only five studies meeting the inclusion criteria. The meta-analysis demonstrated a statistical and clinically relevant reduction in hot flush frequency in the active treatment group compared to placebo. Weighted mean difference 3.63 hot flushes per day: [95% CI 2.70-4.56]; p˂0.00001). Due to a lack of homogeneity a priori defined sub-group analyses were performed demonstrating a substantive difference between cross-over and parallel-arm clinical trial designs. There is evidence for a statistical and clinically significant benefit for using a specific standardised extract of red clover isoflavones (Promensil) at 80mg/day for treating hot flushes in menopausal women across the 3 studies included in the meta-analysis. The preparation was safe over the short-term duration of the studies (3 months). Copyright © 2016 The Authors. Published by Elsevier GmbH.. All rights reserved.
Kwon, Man Jae; O'Loughlin, Edward J; Ham, Baknoon; Hwang, Yunho; Shim, Moojoon; Lee, Soonjae
2018-01-15
Subsurface biogeochemistry and contaminant dynamics during the remediation of diesel-contamination by in-situ soil flushing were investigated at a site located in a coastal region. An in-situ sampler containing diesel-contaminated soils separated into two size fractions (<0.063- and <2-mm) was utilized in two monitoring wells: DH1 (located close to the injection and extraction wells for in-situ soil flushing) and DH2 (located beyond sheet piles placed to block the transport of leaked diesel). Total petroleum hydrocarbon (TPH) concentrations and biogeochemical properties were monitored both in soil and groundwater for six months. A shift occurred in the groundwater type from Ca-HCO 3 to Na-Cl due to seawater intrusion during intense pumping, while the concentrations of Ni, Cu, Co, V, Cr, and Se increased substantially following surfactant (TWEEN 80) injection. The in-situ sampler with fine particles was more sensitive to variations in conditions during the remedial soil flushing process. In both wells, soil TPH concentrations in the <0.063-mm fraction were much higher than those in the <2-mm fraction. Increases in soil TPH in DH1 were consistent with the expected outcomes following well pumping and surfactant injection used to enhance TPH extraction. However, the number of diesel-degrading microorganisms decreased after surfactant injection. 16S-rRNA gene-based analysis also showed that the community composition and diversity depended on both particle size and diesel contamination. The multidisciplinary approach to the contaminated site assessments showed that soil flushing with surfactant enhanced diesel extraction, but negatively impacted in-situ diesel biodegradation as well as groundwater quality. The results also suggest that the in-situ sampler can be an effective monitoring tool for subsurface biogeochemistry as well as contaminant dynamics. Copyright © 2017 Elsevier Ltd. All rights reserved.
Wang, Rui; Luo, Ou; He, Liu; Li, Jia-Xin; Zhang, Ming-Guang
2012-11-01
In Mainland China, heparin saline solution is commonly used for flushing and locking peripheral intravenous access devices in clinical practice for a long time. We conducted a prospective controlled trial to compare the effectiveness and safety of preservative-free 0.9% sodium chloride solution versus heparin saline solution as flushing and locking solution for peripheral intravenous access devices. Patients with gastroenterological or hepatic diseases were enrolled for this study from August 2011 to October 2011. After non-randomized allocation, preservative-free 0.9% sodium chloride was used as flushing and locking solution in the sodium chloride solution group, while hepatic solution (10 U/mL) was given in the heparin saline solution group. The device related complications and its maintenance duration were compared between two groups. One-way ANOVA, Chi(2), or Mantel-Haenszel test were performed using SPSS 13.0 and RevMan 5.0. Totally, 181 and 178 peripheral intravenous access devices in the sodium chloride solution and heparin saline solution groups were included and analyzed. Results indicated than sodium chloride solution did not increase the risks of occlusion (7.7% vs. 7.9%) and other adverse events of peripheral intravenous access devices (P = 0.163). Sodium chloride solution neither shortened the duration of peripheral intravenous access devices maintenance (3.6 ± 1.1 days vs. 3.7 ± 1.2 days, P = 0.651), nor increased the proportion of abnormal withdrawal (29.3% vs. 31.5%, P = 0.654). Sodium chloride solution is as effective and safe as conventional heparin saline solution for flushing and locking peripheral intravenous access devices, which results from our evidence-based study and should be transferred to other nurses in China. © 2012 Wiley Publishing Asia Pty Ltd and Chinese Cochrane Center, West China Hospital of Sichuan University.
Szabo, Jeffrey G; Meiners, Greg; Heckman, Lee; Rice, Eugene W; Hall, John
2017-02-01
Decontamination of Bacillus spores adhered to common drinking water infrastructure surfaces was evaluated using a variety of disinfectants. Corroded iron and cement-mortar lined iron represented the infrastructure surfaces, and were conditioned in a 23 m long, 15 cm diameter (75 ft long, 6 in diameter) pilot-scale drinking water distribution pipe system. Decontamination was evaluated using increased water velocity (flushing) alone at 0.5 m s -1 (1.7 ft s -1 ), as well as free chlorine (5 and 25 mg L -1 ), monochloramine (25 mg L -1 ), chlorine dioxide (5 and 25 mg L -1 ), ozone (2.0 mg L -1 ), peracetic acid 25 mg L -1 ) and acidified nitrite (0.1 mol L -1 at pH 2 and 3), all followed by flushing at 0.3 m s -1 (1 ft s -1 ). Flushing alone reduced the adhered spores by 0.5 and 2.0 log 10 from iron and cement-mortar, respectively. Log 10 reduction on corroded iron pipe wall coupons ranged from 1.0 to 2.9 at respective chlorine dioxide concentrations of 5 and 25 mg L -1 , although spores were undetectable on the iron surface during disinfection at 25 mg L -1 . Acidified nitrite (pH 2, 0.1 mol L -1 ) yielded no detectable spores on the iron surface during the flushing phase after disinfection. Chlorine dioxide was the best performing disinfectant with >3.0 log 10 removal from cement-mortar at 5 and 25 mg L -1 . The data show that free chlorine, monochloramine, ozone and chlorine dioxide followed by flushing can reduce adhered spores by > 3.0 log 10 on cement-mortar. Published by Elsevier Ltd.
Column Testing and 1D Reactive Transport Modeling to Evaluate Uranium Plume Persistence Processes
NASA Astrophysics Data System (ADS)
Johnson, R. H.; Morrison, S.; Morris, S.; Tigar, A.; Dam, W. L.; Dayvault, J.
2015-12-01
At many U.S. Department of Energy Office of Legacy Management sites, 100 year natural flushing was selected as a remedial option for groundwater uranium plumes. However, current data indicate that natural flushing is not occurring as quickly as expected and solid-phase and aqueous uranium concentrations are persistent. At the Grand Junction, Colorado office site, column testing was completed on core collected below an area where uranium mill tailings have been removed. The total uranium concentration in this core was 13.2 mg/kg and the column was flushed with laboratory-created water with no uranium and chemistry similar to the nearby Gunnison River. The core was flushed for a total of 91 pore volumes producing a maximum effluent uranium concentration of 6,110 μg/L at 2.1 pore volumes and a minimum uranium concentration of 36.2 μg/L at the final pore volume. These results indicate complex geochemical reactions at small pore volumes and a long tailing affect at greater pore volumes. Stop flow data indicate the occurrence of non-equilibrium processes that create uranium concentration rebound. These data confirm the potential for plume persistence, which is occurring at the field scale. 1D reactive transport modeling was completed using PHREEQC (geochemical model) and calibrated to the column test data manually and using PEST (inverse modeling calibration routine). Processes of sorption, dual porosity with diffusion, mineral dissolution, dispersion, and cation exchange were evaluated separately and in combination. The calibration results indicate that sorption and dual porosity are major processes in explaining the column test data. These processes are also supported by fission track photographs that show solid-phase uranium residing in less mobile pore spaces. These procedures provide valuable information on plume persistence and secondary source processes that may be used to better inform and evaluate remedial strategies, including natural flushing.
Tidal-flow, circulation, and flushing characteristics of Kings Bay, Citrus County, Florida
Hammett, K.M.; Goodwin, C.R.; Sanders, G.L.
1996-01-01
Kings Bay is an estuary on the gulf coast of peninsular Florida with a surface area of less than one square mile. It is a unique estuarine system with no significant inflowing rivers or streams. As much as 99 percent of the freshwater entering the bay originates from multiple spring vents at the bottom of the estuary. The circulation and flushing characteristics of Kings Bay were evaluated by applying SIMSYS2D, a two-dimensional numerical model. Field data were used to calibrate and verify the model. Lagrangian particle simulations were used to determine the circulation characteristics for three hydrologic conditions: low inflow, typical inflow, and low inflow with reduced friction from aquatic vegetation. Spring discharge transported the particles from Kings Bay through Crystal River and out of the model domain. Tidal effects added an oscillatory component to the particle paths. The mean particle residence time was 59 hours for low inflow with reduced friction; therefore, particle residence time is affected more by spring discharge than by bottom friction. Circulation patterns were virtually identical for the three simulated hydroloigc conditions. Simulated particles introduced in the southern part of Kings Bay traveled along the eastern side of Buzzard Island before entering Crystal River and existing the model domain. The flushing characteristics of Kings Bay for the three hydrodynamic conditions were determined by simulating the injection of conservative dye constituents. The average concentration of dye initially injected in Kings Bay decreased asymptotically because of spring discharge, and the tide caused some oscillation in the average dye concentration. Ninety-five percent of the injected dye exited Kings Bay and Crystal River with 94 hours for low inflow, 71 hours for typical inflow, and 94 hours for low inflow with reduced bottom friction. Simulation results indicate that all of the open waters of Kings Bay are flushed by the spring discharge. Reduced bottom friction has little effect on flushing.
Williams, Laura J; Bunyavejchewin, Sarayudh; Baker, Patrick J
2008-03-01
Seasonal tropical forests exhibit a great diversity of leaf exchange patterns. Within these forests variation in the timing and intensity of leaf exchange may occur within and among individual trees and species, as well as from year to year. Understanding what generates this diversity of phenological behaviour requires a mechanistic model that incorporates rate-limiting physiological conditions, environmental cues, and their interactions. In this study we examined long-term patterns of leaf flushing for a large proportion of the hundreds of tree species that co-occur in a seasonal tropical forest community in western Thailand. We used the data to examine community-wide variation in deciduousness and tested competing hypotheses regarding the timing and triggers of leaf flushing in seasonal tropical forests. We developed metrics to quantify the nature of deciduousness (its magnitude, timing and duration) and its variability among survey years and across a range of taxonomic levels. Tree species varied widely in the magnitude, duration, and variability of leaf loss within species and across years. The magnitude of deciduousness ranged from complete crown loss to no crown loss. Among species that lost most of their crown, the duration of deciduousness ranged from 2 to 21 weeks. The duration of deciduousness in the majority of species was considerably shorter than in neotropical forests with similar rainfall periodicity. While the timing of leaf flushing varied among species, most ( approximately 70%) flushed during the dry season. Leaf flushing was associated with changes in photoperiod in some species and the timing of rainfall in other species. However, more than a third of species showed no clear association with either photoperiod or rainfall, despite the considerable length and depth of the dataset. Further progress in resolving the underlying internal and external mechanisms controlling leaf exchange will require targeting these species for detailed physiological and microclimatic studies.
Li, Zhaosha; Blad, Clara C; van der Sluis, Ronald J; de Vries, Henk; Van Berkel, Theo J C; Ijzerman, Adriaan P; Hoekstra, Menno
2012-10-01
Niacin can effectively treat dyslipidaemic disorders. However, its clinical use is limited due to the cutaneous flushing mediated by the nicotinic acid receptor HCA(2) . In the current study, we evaluated two partial agonists for HCA(2) , LUF6281 and LUF6283, with respect to their anti-dyslipidaemic potential and cutaneous flushing effect. In vitro potency and efficacy studies with niacin and the two HCA(2) partial agonists were performed using HEK293T cells stably expressing human HCA(2) . Normolipidaemic C57BL/6 mice received either niacin or the HCA(2) partial agonists (400 mg·kg(-1) ·day(-1) ) once a day for 4 weeks for evaluation of their effects in vivo. Radioligand competitive binding assay showed K(i) values for LUF6281 and LUF6283 of 3 and 0.55 µM. [(35) S]-GTPγS binding revealed the rank order of their potency as niacin > LUF6283 > LUF6281. All three compounds reduced plasma VLDL-triglyceride concentrations similarly, while LUF6281 and LUF6283, in contrast to niacin, did not also exhibit the unwanted flushing side effect in C57BL/6 mice. Niacin reduced the expression of lipolytic genes HSL and ATGL in adipose tissue by 50%, whereas LUF6281 and LUF6283 unexpectedly did not. In contrast, the decrease in VLDL-triglyceride concentration induced by LUF6281 and LUF6283 was associated with a parallel >40% reduced expression of APOB within the liver. The current study identifies LUF6281 and LUF6283, two HCA(2) partial agonists of the pyrazole class, as promising drug candidates to achieve the beneficial lipid lowering effect of niacin without producing the unwanted flushing side effect. © 2012 The Authors. British Journal of Pharmacology © 2012 The British Pharmacological Society.
2016-07-01
approximately 5 hours (hr) after opening main gates. Multiple channels eroded (Figure 5), moving sediment through the dam throughout the first day...additional sediment evacuation was observed over the next 4 weeks. ERDC/CHL CHETN-XIV-52 July 2016 5 Figure 5. Multiple channels eroded...2015. A physically-based channel - modeling framework integrating HEC-RAS sediment transport capabilities and the USDA-ARS Bank-Stability and Toe-Erosion
Tests Of Array Of Flush Pressure Sensors
NASA Technical Reports Server (NTRS)
Larson, Larry J.; Moes, Timothy R.; Siemers, Paul M., III
1992-01-01
Report describes tests of array of pressure sensors connected to small orifices flush with surface of 1/7-scale model of F-14 airplane in wind tunnel. Part of effort to determine whether pressure parameters consisting of various sums, differences, and ratios of measured pressures used to compute accurately free-stream values of stagnation pressure, static pressure, angle of attack, angle of sideslip, and mach number. Such arrays of sensors and associated processing circuitry integrated into advanced aircraft as parts of flight-monitoring and -controlling systems.
Method and device for disinfecting a toilet bowl
Almon, A.C.
1997-03-18
Method and device are disclosed for disinfecting a flush toilet. The device is an electrolytic cell mounted in the tank of the toilet, with two wire mesh electrodes immersed in the water in the tank and a battery applying approximately one to two volts of electric potential to the electrodes so that they chemically reduce a portion of the water in the tank to hydrogen peroxide. Then, when the tank is flushed, the peroxide is carried into the bowl where it can kill bacteria. 2 figs.
Method and device for disinfecting a toilet bowl
Almon, Amy C.
1997-01-01
Method and device for disinfecting a flush toilet. The device is an electrocell mounted in the tank of the toilet, with two wire mesh electrodes immersed in the water in the tank and a battery applying approximately one to two volts of electric potential to the electrodes so that they chemically reduce a portion of the water in the tank to hydrogen peroxide. Then, when the tank is flushed, the peroxide is carried into the bowl where it can kill bacteria.
Application of a flush airdata sensing system to a wing leading edge (LE-FADS)
NASA Technical Reports Server (NTRS)
Whitmore, Stephen A.; Moes, Timothy R.; Czerniejewski, Mark W.; Nichols, Douglas A.
1993-01-01
This paper investigates the feasibility of locating a flush air-data sensing (FADS) system on a wing leading edge where the operation of the avionics or fire control radar system will not be hindered. The leading-edge FADS system (LE-FADS) was installed on an unswept symmetrical airfoil, and a series of low-speed wind-tunnel tests were conducted to evaluate the performance of the system. As a result of the tests it is concluded that the aerodynamic models formulated for use on aircraft nosetips are directly applicable to wing leading edges and that the calibration process is similar. Furthermore, the agreement between the air-data calculations for angle of attack and total pressure from the LE-FADS and known wind-tunnel values suggest that wing-based flush air-data systems can be calibrated to a high degree of accuracy. Static wind-tunnel tests for angles of attack from -50 to 50 deg and dynamic pressures from 3.6 to 11.4 lb/sq ft were performed.
Flush mounting of thin film sensors
NASA Technical Reports Server (NTRS)
Moore, Thomas C., Sr. (Inventor)
1992-01-01
Flush mounting of a sensor on a surface is provided by first forming a recessed area on the surface. Next, an adhesive bonding mixture is introduced into the recessed area. The adhesive bonding mixture is chosen to provide thermal expansion matching with the surface surrounding the recessed area. A strip of high performance polymeric tape is provided, with the sensor attached to the underside thereof, and the tape is positioned over the recessed area so that it acts as a carrier of the sensor. A shim having flexibility so that it will conform to the surface surrounding the recessed area is placed over the tape, and a vacuum pad is placed over the shim. The area above the surface is then evacuated while holding the sensor flush with the surface during curing of the adhesive bonding mixture. After such curing, the pad, shim, and tape are removed from the sensor, electrical connections for the sensor are provided, after which the remaining space in the recessed area is filled with a polymeric foam.
Application of a Flush Airdata Sensing System to a Wing Leading Edge (LE-FADS)
NASA Technical Reports Server (NTRS)
Whitmore, Stephen A.; Moes, Timothy R.; Czerniejewski, Mark W.; Nichols, Douglas A.
1993-01-01
The feasibility of locating a flush airdata sensing (FADS) system on a wing leading edge where the operation of the avionics or fire control radar system will not be hindered is investigated. The leading-edge FADS system (LE-FADS) was installed on an unswept symmetrical airfoil and a series of low-speed wind-tunnel tests were conducted to evaluate the performance of the system. As a result of the tests it is concluded that the aerodynamic models formulated for use on aircraft nosetips are directly applicable to wing leading edges and that the calibration process is similar. Furthermore, the agreement between the airdata calculations for angle of attack and total pressure from the LE-FADS and known wind-tunnel values suggest that wing-based flush airdata systems can be calibrated to a high degree of accuracy. Static wind-tunnel tests for angles of attack from -50 deg to 50 deg and dynamic pressures from 3.6 to 11.4 lb/sq ft were performed.
NASA Technical Reports Server (NTRS)
Howard, F. G.; Strokowski, A. J.
1978-01-01
Experiments were conducted to determine the reduction in surface skin friction and the effectiveness of surface cooling downstream of one to four successive flush slots injecting cold air at an angle of 10 deg into a turbulent Mach 6 boundary layer. Data were obtained by direct measurement of surface shear and equilibrium temperatures, respectively. Increasing the number of slots decreased the skin friction, but the incremental improvement in skin-friction reduction decreased as the number of slots was increased. Cooling effectiveness was found to improve, for a given total mass injection, as the number of slots was increased from one to four. Comparison with previously reported step-slot data, however, indicated that step slots with tangential injection are more effective for both reducing skin friction and cooling than the present flush-slot configuration. Finite-difference predictions are in reasonable agreement with skin-friction data and with boundary-layer profile data.
Decontamination of Drinking Water Infrastructure ...
Technical Brief This study examines the effectiveness of decontaminating corroded iron and cement-mortar coupons that have been contaminated with spores of Bacillus atrophaeus subsp. globigii (B. globigii), which is often used as a surrogate for pathogenic B. anthracis (anthrax) in disinfection studies. Bacillus spores are persistent on common drinking water material surfaces like corroded iron, requiring physical or chemical methods to decontaminate the infrastructure. In the United States, free chlorine and monochloramine are the primary chemical disinfectants used by the drinking water industry to inactivate microorganisms. Flushing is also a common, easily implemented practice in drinking water distribution systems, although large volumes of contaminated water needing treatment could be generated. Identifying readily available alternative disinfectant formulations for infrastructure decontamination could give water utilities options for responding to specific types of contamination events. In addition to presenting data on flushing alone, which demonstrated the persistence of spores on water infrastructure in the absence of high levels of disinfectants, data on acidified nitrite, chlorine dioxide, free chlorine, monochloramine, ozone, peracetic acid, and followed by flushing are provided.
Althouse, Melissa; Cohen, Jonathan B.; Spendelow, Jeffrey A.; Karpanty, Sarah M.; Davis, Kayla L.; Parsons, Katharine C.; Luttazi, Cristin F.
2016-01-01
Avian research that involves potential disturbance to the study species may have unintended fitness consequences and could lead to biases in measurements of interest. The effects of band resighting on the behavior of mixed-species flocks of staging waterbirds were evaluated against recreational pedestrian activity that was expected to cause flushing. We found a model with additive effects of distance (near, 0-50 m, or far, 50-200 m) and disturbance type (researcher or pedestrian) best explained flock behaviors. The proportion of staging flocks that flushed in response to pedestrians was greatest when pedestrians were within 50 m of the flock. Virtually no flushes were observed in response to researchers, regardless of distance. These results could assist in alleviating concerns that accepted protocols used for intensive band resighting studies on staging seabirds of special conservation status, such as Roseate (Sterna dougallii) and Common (S. hirundo) terns, may have adverse effects. Our framework could be used by others to test the effects of similar research on sensitive species.
[Effect of concomitant substances and addition order on the adsorption of Tween 80 on sand].
Xu, Wei; Zhao, Yong-sheng; Li, Sui; Dai, Ning
2008-08-01
Adsorption of Tween 80 on sand was investigated, and the effect of inorganic salts (CaCl2), anionic surfactant (SDS) and lignosulphonates (sodium lignosulphonate or ammonium lignosulphonate) on the adsorption of Tween 80 on sand were evaluated at 25 degrees C. The results show that saturated adsorption amount of Tween 80 on sand enhance when CaCl2 or SDS is added into flushing solution of Tween 80. And the adsorption of Tween 80 on sand increase with the increase of molar fraction of CaCl2 or SDS in mixed flushing solution. And adsorption amount of Tween 80 on sand also enhance when SDS is added into sand firstly. The effects of mixing ratios and addition order of lignosulphonates on adsorption of Tween 80 were considered. The results show that with the increase of molar fraction of lignosulphonates in mixing flushing solution, adsorption amount of Tween 80 on sand decrease. The adsorption amount of Tween 80 reduce 20%-75% due to the exist of ammonium lignosulphonate is superior to sodium lignosulphonate (10%-60%) when mix the lignosulphonates-Tween 80 at the total mass ratios of 1:10, while the adsorption amount of Tween 80 reduce 70%-90% at the total mass ratios of 1:2. Lignosulphonates added into sand firstly is more efficient than that together. Therefore,use of lignosulphonates as a preflush can reduce the adsorption of surfactants on sand and is a better method to applied in in situ flushing.
Chen, Ming-Jen; Wang, Horng-Yuan; Chang, Chen-Wang; Hu, Kuang-Chun; Hung, Chien-Yuan; Chen, Chih-Jen; Shih, Shou-Chuan
2013-02-01
Recent studies have shown that pronase can improve mucosal visibility, but this agent is not uniformly available for human use worldwide. This study aimed to assess the efficacy of N-acetylcysteine (NAC), a mucolytic agent, in improving mucus elimination as measured by decreased endoscopic water flushes during narrow-band imaging (NBI) endoscopy. A consecutive series of patients scheduled for upper gastrointestinal endoscopy at outpatient clinics were enrolled in this double-blind, randomized controlled trial. The control group drank a preparation of 100 mg dimethicone (5 ml at 20 mg/ml) plus water up to 100 ml, and the NAC group drank 300 mg NAC plus 100 mg dimethicone and water up to 100 ml. During the endoscopy, the endoscopist used as many flushes of water as deemed necessary to produce a satisfactory NBI view of the entire gastric mucosa. In all, 177 patients with a mean age of 51 years were evaluated in this study. Significantly lesser water was used for flushing during NBI endoscopy for the NAC group than the control group; 40 ml (30-70, 0-120) versus 50 ml (30-100, 0-150) (median (interquartile range, range), p = 0.0095). Considering the safety profile of NAC, decreasing the number of water flushes for optimal vision and unavailability of pronase in some areas, the authors suggest the use of add-on NAC to eliminate mucus during NBI endoscopy.
NASA Technical Reports Server (NTRS)
Lewis, James P.
1953-01-01
An investigation has been made in the NACA Lewis icing research tunnel to determine the aerodynamic and icing characteristics of a full-scale induction-system air-scoop assembly incorporating a flush alternate inlet. The flush inlet was located immediately downstream of the offset ram inlet and included a 180 deg reversal and a 90 deg elbow in the ducting between inlet and carburetor top deck. The model also had a preheat-air inlet. The investigation was made over a range of mass-air- flow ratios of 0 to 0.8, angles of attack of 0 and 4 deg airspeeds of 150 to 270 miles per hour, air temperatures of 0 and 25 F various liquid-water contents, and droplet sizes. The ram inlet gave good pressure recovery in both clear air and icing but rapid blockage of the top-deck screen occurred during icing. The flush alternate inlet had poor pressure recovery in both clear air and icing. The greatest decreases in the alternate-inlet pressure recovery were obtained at icing conditions of low air temperature and high liquid-water content. No serious screen icing was observed with the alternate inlet. Pressure and temperature distributions on the carburetor top deck were determined using the preheat-air supply with the preheat- and alternate-inlet doors in various positions. No screen icing occurred when the preheat-air system was operated in combination with alternate-inlet air flow.
Statistical modelling of suspended sediment load in small basin located at Colombian Andes
NASA Astrophysics Data System (ADS)
Javier, Montoya Luis
2016-04-01
In this study a statistical modelling for the estimate the sediment yield based on available observations of water discharge and suspended sediment concentration were done. A multivariate model was applicate to analyze the 33 years of daily suspended sediments load available at a La Garrucha gauging station. A regional analysis were conducted to find a non-dimensional sediment load duration curve. These curves were used to estimate flow and sediments regimen at other inner point at the basin where there are located the Calderas reservoir. The record of sedimentation in the reservoir were used to validate the estimate mean sediments load. A periodical flushing in the reservoir is necessary to maintain the reservoir at the best operating capacity. The non-dimensional sediment load duration curve obtaining was used to find a sediment concentration during high flow regimen (10% of time these values were met or exceeded).These sediment concentration of high flow regimen has been assumed as a concentration that allow an 'environmental flushing', because it try to reproduce the natural regimen of sediments at the river and it sends a sediment concentration that environment can withstand. The sediment transport capacity for these sediment load were verified with a 1D model in order to respect the environmental constraints downstream of the dam. Field data were collected to understand the physical phenomena involved in flushing dynamics in the reservoir and downstream of the dam. These model allow to define an operations rules for the flushing to minimize the environmental effects.
Fukazawa, Kyota; Nishida, Seigo; Hibi, Taizo; Pretto, Ernesto A
2013-01-01
During liver transplant (LT), the release of vasoactive substances into the systemic circulation is associated with severe hemodynamic instability that is injurious to the recipient and/or the post-ischemic graft. Crystalloid flush with backward unclamping (CB) and portal blood flush with forward unclamping (PF) are two reperfusion methods to reduce reperfusion-related cardiovascular perturbations in our center. The primary aim of this study was to compare these two methods. After institutional review board (IRB) approval, cadaveric whole LT cases performed between 2003 and 2008 were reviewed. Patients were divided into two groups based on reperfusion methods: CB or PF. After background matching with propensity score, the effect of each method on post-operative graft function was assessed in detail. In our cohort of 478 patients, CB was used in 313 grafts and PF in 165. Thirty-day graft survival was lower, and risk of retransplantation was higher in PF. Multivariable model showed that CB is an independent factor to reduce primary non-function, cardiac arrest and improve 30-d graft survival. Also, the incidence of ischemic-type biliary lesions was significantly higher in the PF group. Reperfusion methods affect intraoperative hemodynamics and post-transplant outcome. CB allows for control over temperature and composition of the perfusate, perfusion pressure, and the rate of infusion. © 2013 John Wiley & Sons A/S.
Spatially Estimating Disturbance of Harbor Seals (Phoca vitulina)
Jansen, John K.; Brady, Gavin M.; Ver Hoef, Jay M.; Boveng, Peter L.
2015-01-01
Tidewater glacial fjords in Alaska provide habitat for some of the largest aggregations of harbor seals (Phoca vitulina), with calved ice serving as platforms for birthing and nursing pups, molting, and resting. These fjords have also been popular destinations for tour ships for more than a century, with dramatic increases in vessel traffic since the 1980s. Seals on ice are known to flush into the water when approached by tour ships, but estimating the exposure to disturbance across populations is difficult. Using aerial transect sampling while simultaneously tracking vessel movements, we estimated the spatial overlap between seals on ice and cruise ships in Disenchantment Bay, Alaska, USA. By integrating previously estimated rates of disturbance as a function of distance with an ‘intensity surface’ modeled spatially from seal locations in the surveys, we calculated probabilities of seals flushing during three separate ship visits. By combining our estimate of seals flushed with a modeled estimate of the total fjord population, we predict that up to 14% of the seals (up to 11% of pups) hauled out would have flushed into the water, depending on the route taken by ships relative to seal aggregations. Such high potential for broad-scale disturbance by single vessels (when up to 4 ships visit per day) was unexpected and underscores the need to 1) better understand long-term effects of disturbance; 2) regularly monitor populations exposed to high vessel traffic; and 3) develop conservation measures to reduce seal-ship overlap. PMID:26132083
NASA Astrophysics Data System (ADS)
Sebestyen, S. D.; Shanley, J. B.; Boyer, E. W.; Kendall, C.
2004-12-01
Our ability to assess how stream nutrient concentrations respond to biogeochemical transformations and stream flow dynamics is often limited by datasets that do not include all flow conditions that occur over event, monthly, seasonal, and yearly time scales. At the Sleepers River Research Watershed in northeastern Vermont, USA, nitrate, DOC (dissolved organic carbon), and major ion concentrations were measured on samples collected over a wide range of flow conditions from summer 2002 through summer 2004. Nutrient flushing occurred at the W-9 catchment and high-frequency sampling revealed critical insights into seasonal and event-scale controls on nutrient concentrations. In this seasonally snow-covered catchment, the earliest stage of snowmelt introduced nitrogen directly to the stream from the snowpack. As snowmelt progressed, the source of stream nitrate shifted to flushing of soil nitrate along shallow subsurface flow paths. In the growing season, nitrogen flushing to streams varied with antecedent moisture conditions. More nitrogen was available to flush to streams when antecedent moisture was lowest, and mobile nitrogen stores in the landscape regenerated under baseflow conditions on times scales as short as 7 days. Leaf fall was another critical time when coupled hydrological and biogeochemical processes controlled nutrient fluxes. With the input of labile organic carbon from freshly decomposing leaves, nitrate concentrations declined sharply in response to in-stream immobilization or denitrification. These high-resolution hydrochemical data from multiple flow regimes are identifying "hot spots" and "hot moments" of biogeochemical and hydrological processes that control nutrient fluxes in streams.
Air-gas exchange reevaluated: clinically important results of a computer simulation.
Shunmugam, Manoharan; Shunmugam, Sudhakaran; Williamson, Tom H; Laidlaw, D Alistair
2011-10-21
The primary aim of this study was to evaluate the efficiency of air-gas exchange techniques and the factors that influence the final concentration of an intraocular gas tamponade. Parameters were varied to find the optimum method of performing an air-gas exchange in ideal circumstances. A computer model of the eye was designed using 3D software with fluid flow analysis capabilities. Factors such as angular distance between ports, gas infusion gauge, exhaust vent gauge and depth were varied in the model. Flow rate and axial length were also modulated to simulate faster injections and more myopic eyes, respectively. The flush volume of gas required to achieve a 97% intraocular gas fraction concentration were compared. Modulating individual factors did not reveal any clinically significant difference in the angular distance between ports, exhaust vent size, and depth or rate of gas injection. In combination, however, there was a 28% increase in air-gas exchange efficiency comparing the most efficient with the least efficient studied parameters in this model. The gas flush volume required to achieve a 97% gas fill also increased proportionately at a ratio of 5.5 to 6.2 times the volume of the eye. A 35-mL flush is adequate for eyes up to 25 mm in axial length; however, eyes longer than this would require a much greater flush volume, and surgeons should consider using two separate 50-mL gas syringes to ensure optimal gas concentration for eyes greater than 25 mm in axial length.
Maheux-Lacroix, Sarah; Dodin, Sylvie; Moore, Lynne; Bujold, Emmanuel; Lefebvre, Jessica; Bergeron, Marie-Ève
2016-01-06
In vitro fertilisation (IVF) is the treatment of choice for unexplained infertility. Preovulatory uterine flushing could reduce intrauterine debris and inflammatory factors preventing pregnancy and constitute an alternative to IVF. Our objective is to assess the efficacy of preovulatory uterine flushing with physiological saline for the treatment of unexplained infertility. We will perform a randomised controlled trial based on consecutive women aged between 18 and 37 years consulting for unexplained infertility for at least 1 year. On the day of their luteinising hormone surge, 192 participants will be randomised in two equal groups to either receive 20 mL of physiological saline by an intrauterine catheter or 10 mL of saline intravaginally. We will assess relative risk of live birth (primary outcome), as well as pregnancy (secondary outcome) over one cycle of treatment. We will report the side effects, complications and acceptability of the intervention. This project was approved by the Ethics committee of the Centre Hospitatlier Universitaire de Quebec (no 2015-1146). Uterine flushing is usually well tolerated by women and would constitute a simple, affordable and minimally invasive treatment for unexplained infertility. We plan to communicate the results of the review by presenting research abstracts at conferences and by publishing the results in a peer-reviewed journal. NCT02539290; Pre-results. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Song, Yan; Wang, Xiaoli; Perlstein, Itay; Wang, Jessie; Badawy, Sherif; Frost, Charles; LaCreta, Frank
2015-08-01
Crushed tablet and solution formulations of apixaban administered orally or via a nasogastric tube (NGT) may be useful in patients unable to swallow solid dose formulations. It is important to understand whether new formulations and/or methods of administration impact apixaban bioavailability and pharmacokinetic properties. These studies evaluated the relative bioavailability (Frel) of apixaban solution administered orally; oral solution administered via NGT flushed with either 5% dextrose in water (D5W) or with infant formula; oral solution via NGT with a nutritional supplement; and crushed tablet suspended in D5W and administered via NGT. Three open-label, randomized, crossover studies were conducted in healthy adults (study 1: apixaban 10-mg tablet [reference] versus oral solution, both administered PO; study 2: apixaban 5-mg oral solution PO [reference] versus oral solution via NGT flushed with either D5W or infant formula; study 3: apixaban 5-mg oral solution PO [reference] versus apixaban 5-mg oral solution via NGT with a nutritional supplement and versus crushed tablet suspended in D5W and administered via NGT). Point estimates and 90% CIs of the geometric mean ratios (GMRs; test/reference) were generated for Cmax and AUC. Adverse events were recorded throughout each study. Frel of the oral solution was 105% versus tablet, and Frel for oral solution via NGT with D5W flush, infant formula flush, nutritional supplement, and crushed tablet via NGT versus oral solution administration were 96.7%, 92.2%, 81.3%, and 95.1%, respectively. The 90% CIs of the GMRs of all AUCs met the bioequivalence criterion except that of the nutritional supplement (0.766-0.863). The corresponding GMRs for Cmax were 0.977, 0.953, 0.805, 0.682, and 0.884. For the solution via NGT flushed with D5W and for the crushed tablet, the 90% CIs of the Cmax GMRs met the bioequivalence criterion. Apixaban was well tolerated in all 3 studies; most adverse events were mild. Comparable Frel was observed for oral apixaban solution, tablet, NGT administration of solution flushed with D5W and infant formula, and NGT administration of crushed tablet suspension. Exposure was less when oral solution was administered via NGT with nutritional supplement. These results support several alternative methods of administering apixaban that may be useful in certain clinical situations. ClinicalTrials.gov identifiers: NCT02034565, NCT02034578, and NCT02034591. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.
Design of compound libraries for fragment screening
NASA Astrophysics Data System (ADS)
Blomberg, Niklas; Cosgrove, David A.; Kenny, Peter W.; Kolmodin, Karin
2009-08-01
Approaches to the design of libraries for fragment screening are illustrated with reference to a 20 k generic fragment screening library and a 1.2 k generic NMR screening library. Tools and methods for library design that have been developed within AstraZeneca are described, including Foyfi fingerprints and the Flush program for neighborhood characterization. It will be shown how Flush and the BigPicker, which selects maximally diverse sets of compounds, are used to apply the Core and Layer method for library design. Approaches to partitioning libraries into cocktails are also described.
Hale, C.J.
1983-11-15
An assembly for mounting a pH probe in a flowing solution, such as a sanitary sewer line, which prevents the sensitive glass portion of the probe from becoming coated with grease, oil, and other contaminants, whereby the probe gives reliable pH indication over an extended period of time. The pH probe assembly utilizes a special filter media and a timed back-rinse feature for flushing clear surface contaminants of the filter. The flushing liquid is of a known pH and is utilized to check performance of the probe. 1 fig.
Column Testing and 1D Reactive Transport Modeling to Evaluate Uranium Plume Persistence Processes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Johnson, Raymond H.; Morrison, Stan; Morris, Sarah
Motivation for Study: Natural flushing of contaminants at various U.S. Department of Energy Office of Legacy Management sites is not proceeding as quickly as predicted (plume persistence) Objectives: Help determine natural flushing rates using column tests. Use 1D reactive transport modeling to better understand the major processes that are creating plume persistence Approach: Core samples from under a former mill tailings area Tailings have been removed. Column leaching using lab-prepared water similar to nearby Gunnison River water. 1D reactive transport modeling to evaluate processes
Hale, Charles J.
1983-01-01
An assembly for mounting a pH probe in a flowing solution, such as a sanitary sewer line, which prevents the sensitive glass portion of the probe from becoming coated with grease, oil, and other contaminants, whereby the probe gives reliable pH indication over an extended period of time. The pH probe assembly utilizes a special filter media and a timed back-rinse feature for flushing clear surface contaminants of the filter. The flushing liquid is of a known pH and is utilized to check performance of the probe.
Decision Support on the Sediments Flushing of Aimorés Dam Using Medium-Range Ensemble Forecasts
NASA Astrophysics Data System (ADS)
Mainardi Fan, Fernando; Schwanenberg, Dirk; Collischonn, Walter; Assis dos Reis, Alberto; Alvarado Montero, Rodolfo; Alencar Siqueira, Vinicius
2015-04-01
In the present study we investigate the use of medium-range streamflow forecasts in the Doce River basin (Brazil), at the reservoir of Aimorés Hydro Power Plant (HPP). During daily operations this reservoir acts as a "trap" to the sediments that originate from the upstream basin of the Doce River. This motivates a cleaning process called "pass through" to periodically remove the sediments from the reservoir. The "pass through" or "sediments flushing" process consists of a decrease of the reservoir's water level to a certain flushing level when a determined reservoir inflow threshold is forecasted. Then, the water in the approaching inflow is used to flush the sediments from the reservoir through the spillway and to recover the original reservoir storage. To be triggered, the sediments flushing operation requires an inflow larger than 3000m³/s in a forecast horizon of 7 days. This lead-time of 7 days is far beyond the basin's concentration time (around 2 days), meaning that the forecasts for the pass through procedure highly depends on Numerical Weather Predictions (NWP) models that generate Quantitative Precipitation Forecasts (QPF). This dependency creates an environment with a high amount of uncertainty to the operator. To support the decision making at Aimorés HPP we developed a fully operational hydrological forecasting system to the basin. The system is capable of generating ensemble streamflow forecasts scenarios when driven by QPF data from meteorological Ensemble Prediction Systems (EPS). This approach allows accounting for uncertainties in the NWP at a decision making level. This system is starting to be used operationally by CEMIG and is the one shown in the present study, including a hindcasting analysis to assess the performance of the system for the specific flushing problem. The QPF data used in the hindcasting study was derived from the TIGGE (THORPEX Interactive Grand Global Ensemble) database. Among all EPS available on TIGGE, three were selected: ECMWF, GEFS, and CPTEC. As a deterministic reference forecast, we adopt the high resolution ECMWF forecast for comparison. The experiment consisted on running retrospective forecasts for a full five-year period. To verify the proposed objectives of the study, we use different metrics to evaluate the forecast: ROC Curves, Exceedance Diagrams, Forecast Convergence Score (FCS). Metrics results enabled to understand the benefits of the hydrological ensemble prediction system as a decision making tool for the HPP operation. The ROC scores indicate that the use of the lower percentiles of the ensemble scenarios issues for a true alarm rate around 0,5 to 0,8 (depending on the model and on the percentile), for the lead time of seven days. While the false alarm rate is between 0 and 0,3. Those rates were better than the ones resulting from the deterministic reference forecast. Exceedance diagrams and forecast convergence scores indicate that the ensemble scenarios provide an early signal about the threshold crossing. Furthermore, the ensemble forecasts are more consistent between two subsequent forecasts in comparison to the deterministic forecast. The assessments results also give more credibility to CEMIG in the realization and communication of flushing operation with the stakeholders involved.
Response Characteristics of Dissolved Organic Carbon Flushing in a Subarctic Alpine Catchment
NASA Astrophysics Data System (ADS)
Carey, S. K.
2002-12-01
Dissolved organic carbon (DOC) is an important part of ecosystem-scale carbon balances and in the transport of contaminants as it interacts with other dissolved substances including trace metals. It also can be used as a surrogate hydrological tracer in permafrost regions as near-surface waters are often DOC enriched due to the presence of thick organic soils. In a small subarctic alpine catchment within the Wolf Creek Research Basin, Yukon, Canada, DOC was studied in the summer of 2001 and spring of 2002 to determine the role frost (both permanent and seasonal), snowmelt and summer storms on DOC flushing. Peak DOC concentrations occurred during the snowmelt period, approximately one week prior to peak discharge. However, peak discharge took place several weeks after snow on south facing exposures had melted. Within the hillslopes, DOC concentrations were three to five times greater in wells underlain with permafrost compared with seasonal frost. Groundwater DOC concentrations declined during snowmelt, yet remained at levels above the streamflow. After peaking, streamflow DOC concentrations declined exponentially suggesting a simple flushing mechanism, however there did not appear to be a relation between DOC and topographic position. Following melt, permafrost underlain slopes had near-surface water tables and retained elevated levels of DOC, whereas slopes without permafrost had rapidly declining water tables at upslope locations with low DOC concentrations at all positions except near-stream riparian zones. The influence of summer rainstorms on DOC was monitored on three occasions. In each case DOC peaked on the ascending limb of the runoff hydrograph and declined exponentially on the receding limb and hysteretic behavior occurred between discharge and DOC during all events. Patterns of DOC within the hillslopes and streams suggest that runoff from permafrost-underlain slopes control DOC flushing within the stream during both snowmelt and summer periods. This flushing mechanism conforms with conceptual models of runoff generation in discontinuous permafrost catchments whereby water tables within permafrost-underlain slopes rise into porous organic-layers, whereupon DOC is leached into the water and rapidly conveyed to the stream.
Marenzoni, Maria Luisa; Sforna, Monica; Stefanetti, Valentina; Casagrande Proietti, Patrizia; Brignone, Luca; Del Sero, Andrea; Falcioni, Fabio; Orvieto, Simona; Tamantini, Cristina; Tiburzi, Alessandra; Valentini, Silvia; Coletti, Mauro; Timoney, Peter J; Passamonti, Fabrizio
2014-12-05
In recent years, there has been increasing evidence of the potential pathogenic significance of equine gammaherpesviruses in the horse. In humans, cattle and mice, gammaherpesviruses have already been associated with uterine infection. The aim of the present study was to investigate the presence of gammaherpesviruses in uterine flushings of mares with reproductive problems and to evaluate if there was a possible statistical association with clinical and laboratory findings in these cases. A total of 80 uterine flushings were collected from 61 mares with different reproductive problems and these were tested for equine herpesviruses (EHV) 1-5 by PCR. In the case of each mare in the study, the age, history of infertility, presence of anatomical defects in the reproductive tract, presence of systemic or local disease at time of sampling, phase in the oestrous cycle, post-partum interval, nature of uterine lavage performed (low versus large volume lavage), cytological and bacteriological examination results from the uterine flushing, and PCR herpesvirus results were recorded. Univariate analysis and multivariable logistic regression models were used to identify possible statistical associations and risk factors. Nine out of 61 mares (14.7%) had EHV-5 DNA in their uterine flushings. Co-infections with EHV-1 and EHV-2 were present in two cases. Of all the variables analyzed, only the cytological examination findings were associated with EHV-5 PCR positive results, both on univariate and multivariable analysis, especially in cases with an inflammation score of 3. It is postulated that presence of EHV-5 infection in the non-pregnant uterus may have a role to play in reproductive dysfunction and have a negative consequence on the pregnant uterus. Additional studies involving both healthy mares and mares with reproductive problems need to be performed, however, to elucidate whatever role equine gammaherpesviruses may play in the reproductive tract. This would be very worthwhile, since reproductive problems can have a significant impact on the equine breeding industry. Gaining a greater understanding of its causes could lead to new approaches for prevention and treatment. Copyright © 2014 Elsevier B.V. All rights reserved.
Anand, C; Apul, D S
2011-03-01
The current sanitation technology in developed countries is based on diluting human excreta with large volumes of centrally provided potable water. This approach is a poor use of water resources and is also inefficient, expensive, and energy intensive. The goal of this study was to compare the standard sanitation technology (Scenario 1) with alternative technologies that require less or no potable water use in toilets. The alternative technologies considered were high efficiency toilets flushed with potable water (Scenario 2), standard toilets flushed with rainwater (Scenario 3), high efficiency toilets flushed with rainwater (Scenario 4), and composting toilets (Scenario 5). Cost, energy, and carbon implications of these five design scenarios were studied using two existing University of Toledo buildings. The results showed that alternative systems modeled in Scenarios 2, 4, and 5 were viable options both from an investment and an environmental performance perspective. High efficiency fixtures that use potable water (Scenario 2) is often the most preferred method in high efficiency buildings due to reduced water use and associated reductions in annual water and wastewater costs. However, the cost, energy, and CO(2)EE analyses all showed that Scenarios 4 and 5 were preferable over Scenario 2. Cost payback periods of scenarios 2, 4 and 5 were less than 10 years; in the future, increase in water and wastewater services would further decrease the payback periods. The centralized water and wastewater services have high carbon footprints; therefore if carbon footprint reduction is a primary goal of a building complex, alternative technologies that require less potable water and generate less wastewater can largely reduce the carbon footprint. High efficiency fixtures flushed with rainwater (Scenario 4) and composting toilets (Scenario 5) required considerably less energy than direct energy demands of buildings. However, the annual carbon footprint of these technologies was comparable to the annual carbon footprint from space heating. Similarly, the carbon savings that could be achieved from Scenario 4 or 5 were comparable to a recycling program that can be implemented in buildings. Copyright © 2010 Elsevier Ltd. All rights reserved.
Randolph, Adrienne G; Cook, Deborah J; Gonzales, Calle A; Andrew, Maureen
1998-01-01
Objective: To evaluate the effect of heparin on duration of catheter patency and on prevention of complications associated with use of peripheral venous and arterial catheters. Design: Critical appraisal and meta-analysis of 26 randomised controlled trials that evaluated infusion of heparin intermittently or continuously. Thirteen trials of peripheral venous catheters and two of peripheral arterial catheters met criteria for inclusion. Main outcome measures: Data on the populations, interventions, outcomes, and methodological quality. Results: For peripheral venous catheters locked between use flushing with 10 U/ml of heparin instead of normal saline did not reduce the incidence of catheter clotting and phlebitis or improve catheter patency. When heparin was given as a continuous infusion at 1 U/ml the risk of phlebitis decreased (relative risk 0.55; 95% confidence interval 0.39 to 0.77), the duration of patency increased, and infusion failure was reduced (0.88; 0.72 to 1.07). Heparin significantly prolonged duration of patency of radial artery catheters and decreased the risk of clot formation (0.51; 0.42 to 0.61). Conclusions: Use of intermittent heparin flushes at doses of 10 U/ml in peripheral venous catheters locked between use had no benefit over normal saline flush. Infusion of low dose heparin through a peripheral arterial catheter prolonged the duration of patency but further study is needed to establish its benefit for peripheral venous catheters. Key messages Despite almost universal use, agreement has not been reached on the need to administer heparin through peripheral intravascular catheters The results of 13 trials on peripheral venous catheters and two trials on peripheral arterial catheters were critically appraised to clarify what evidence supports the use of heparin Flushing peripheral venous catheters locked between use with heparinised saline at 10 U/ml is no more beneficial than flushing with normal saline Heparin significantly prolongs the duration of peripheral arterial catheter patency and decreases the risk of clot formation In peripheral venous catheters heparin added to the infusion at 1 U/ml decreases phlebitis and may prolong duration of catheter patency and decrease infusion failure PMID:9550955
Coates, D
2001-05-01
Microbiological tests were carried out to evaluate a new chlorine dioxide sterilant: Tristel OneShot. Preliminary in vitro suspension tests showed that solutions containing around 140 ppm chlorine dioxide achieved a reduction factor exceeding 10(6) of Staphylococcus aureus in 1min and of Bacillus subtilis spores in 2.5 min in the presence of 3g/L bovine albumin. Subsequent tests evaluated the effectiveness of Tristel One-Shot in a Medivator washer/disinfector fitted with a Tristel Generator for processing flexible endoscopes. Each test run involved three stages. In the first, the instrument and air-water channels of a gastroscope were inoculated with a suspension of Pseudomonas aeruginosa (10(8)cfu/ml) in 10% sodium glutamate and serum (0, 5 or 10%) and then drained, partially dried, and saline flushed through for total viable counts (TVCs). In the second stage, the channels were re-inoculated with test organisms; detergent was flushed through the channels which were then brushed; and saline was flushed through for TVCs. In the third stage, the channels were re-inoculated; detergent was flushed through the channels which were then brushed; the endoscope was processed in the Medivator; and saline was flushed through for TVCs. Carrying out all three stages enabled determination of (1) the contribution played by manual cleaning of channels prior to processing in the Medivator, and (2) the combined effect of manual cleaning followed by processing. Two series of test runs were done. In the first, the Tristel Generator was set to generate 230ppm chlorine dioxide, and in the second 150ppm. In the first, cleaning followed by processing in the Medivator consistently achieved a >/= 10(6)-fold reduction of test organisms, and in the second a >/= 10(5)-fold reduction. Pre-cleaning of channels was very important-when done the initial concentration of serum in the inoculum (0-10%) had no affect on the results obtained after processing. Copyright 2001 The Hospital infection Society.
Khan, Shouket Zaman; Arif, Muhammad Jalal; Hoddle, Christina D; Hoddle, Mark S
2014-10-01
The population phenology of Asian citrus psyllid, Diaphorina citri Kuwayama, was monitored weekly for 110 wk on two species of Citrus, kinnow mandarin and sweet orange, at two different research sites in Faisalabad, Punjab Pakistan. Citrus flush growth patterns were monitored and natural enemy surveys were conducted weekly. Flush patterns were similar for kinnow and sweet orange. However, flush on sweet orange was consistently more heavily infested with Asian citrus psyllid than kinnow flush; densities of Asian citrus psyllid eggs, nymphs, and adults were higher on sweet orange when compared with kinnow. When measured in terms of mean cumulative insect or Asian citrus psyllid days, eggs, nymphs, and adults were significantly higher on sweet orange than kinnow. Two parasitoids were recorded attacking Asian citrus psyllid nymphs, Tamarixia radiata (Waterston) and Diaphorencyrtus aligarhensis (Shafee, Alam and Agarwal). The dominant parasitoid species attacking Asian citrus psyllid nymphs on kinnow and sweet orange was T. radiata, with parasitism averaging 26%. D. aligarhensis parasitism averaged 17%. Generalist predators such as coccinellids and chrysopids were collected infrequently and were likely not important natural enemies at these study sites. Immature spiders, in particular, salticids and yellow sac spiders, were common and may be important predators of all Asian citrus psyllid life stages. Low year round Asian citrus psyllid densities on kinnow and possibly high summer temperatures, may, in part, contribute to the success of this cultivar in Punjab where Candidatus Liberibacter asiaticus, the putative causative agent of huanglongbing, a debilitating citrus disease, is widespread and vectored by Asian citrus psyllid.
Byrne, Frank J; Humeres, Eduardo C; Urena, Anthony A; Hoddle, Mark S; Morse, Joseph G
2010-10-01
The efficacy of systemic applications of imidacloprid for the management of avocado thrips and avocado lace bug was determined in field trials. Following insecticide treatment by chemigation, leaves of appropriate age for each insect were sampled over a 6 month period and used for bioassays. Imidacloprid residues were measured by ELISA in leaves used for bioassays to determine concentrations of insecticide that were toxic to both pests. The uptake of imidacloprid into treated trees was extremely slow, peaking in the current year's leaf flush at only 8 ng cm(-2) leaf tissue after 15 weeks. Avocado thrips mortality in bioassays with young flush leaves, the preferred feeding substrate for this insect, was minimal, indicating that imidacloprid concentrations were below threshold levels needed for effective control. Residues present in older leaves, which are preferred by the avocado lace bug, were higher than in young flush leaves, and provided good control of this pest. Probit analysis of bioassay data showed that the avocado lace bug (LC(50) = 6.1 ng imidacloprid cm(-2) leaf tissue) was more susceptible to imidacloprid than the avocado thrips (LC(50) = 73 ng imidacloprid cm(-2) leaf tissue). In spite of the slow uptake of imidacloprid into avocado trees, the levels of imidacloprid would be sufficient to control avocado lace bug infestations. In contrast, the slow uptake would be problematic for avocado thrips control because inadequate levels of insecticide accumulate in new flush foliage and would allow avocado thrips populations to build to levels that would subsequently damage developing avocado fruit.
Does menopause influence nocturnal awakening with headache?
Lucchesi, L M; Hachul, H; Yagihara, F; Santos-Silva, R; Tufik, S; Bittencourt, L
2013-06-01
The aim of the present study was to assess whether menopausal status influences the occurrence of nocturnal awakening with headache (NAH) in the female population of Sao Paulo, Brazil. We also examined the relationship of this complaint to sociodemographic determinants, hot flushes, sleep quality and parameters, anxiety and depressive symptoms, somnolence and fatigue according to menopausal status. The female population of the Sao Paulo Epidemiologic Sleep Study (EPISONO) (n = 576) was divided according to menopausal status (pre-, peri-, early and late menopause) based on questionnaires and hormonal blood measures. The complaint of waking up because of a headache at least once a week was assessed by the UNIFESP Sleep questionnaire. Additionally, hot flushes, sleep complaints, anxiety and depressive symptoms, somnolence and fatigue were assessed by specific questionnaires. A full-night polysomnography assessed sleep parameters. The prevalence of NAH in women in the Sao Paulo population was 13.3%. Perimenopause was associated with a higher risk of having NAH (odds ratio 13.9; 95% confidence interval 4.3-45.2). More complaints of NAH were observed in obese women. All the groups with NAH showed more hot flushes, worse subjective sleep quality, more complaints of insomnia, anxiety symptoms and fatigue. We observed a constellation of symptoms in women according to menopausal status and NAH that included hot flushes, sleep complaints, more anxiety symptoms and fatigue. Moreover, some of these symptoms were more frequent in perimenopausal women with NAH. Therefore, we concluded that menopausal status influences NAH and the women in perimenopause presented a high risk of having this complaint.
Alcohol drinking and risk of Parkinson's disease: a case-control study in Japan
2010-01-01
Background Although some epidemiologic studies found inverse associations between alcohol drinking and Parkinson's disease (PD), the majority of studies found no such significant associations. Additionally, there is only limited research into the possible interactions of alcohol intake with aldehyde dehydrogenase (ALDH) 2 activity with respect to PD risk. We examined the relationship between alcohol intake and PD among Japanese subjects using data from a case-control study. Methods From 214 cases within 6 years of PD onset and 327 controls without neurodegenerative disease, we collected information on "peak", as opposed to average, alcohol drinking frequency and peak drinking amounts during a subject's lifetime. Alcohol flushing status was evaluated via questions, as a means of detecting inactive ALHD2. The multivariate model included adjustments for sex, age, region of residence, smoking, years of education, body mass index, alcohol flushing status, presence of selected medication histories, and several dietary factors. Results Alcohol intake during peak drinking periods, regardless of frequency or amount, was not associated with PD. However, when we assessed daily ethanol intake separately for each type of alcohol, only Japanese sake (rice wine) was significantly associated with PD (adjusted odds ratio of ≥66.0 g ethanol per day: 3.39, 95% confidence interval: 1.10-11.0, P for trend = 0.001). There was no significant interaction of alcohol intake with flushing status in relation to PD risk. Conclusions We did not find significant associations between alcohol intake and PD, except for the daily amount of Japanese sake. Effect modifications by alcohol flushing status were not observed. PMID:21054827
Kaczala, Fabio; Marques, Marcia; Vinrot, Eva; Hogland, William
2012-01-01
The stormwater run-off generated in an industrial log yard during eight run-off events was studied with the main focus on the transport of toxic metals. Associations between water quality constituents and potential surrogates were evaluated by correlation analysis. The first-flush phenomenon was verified by normalized M(V) curves. The results have shown that, whereas some metals such as Zn, Ba, Cd, As and Fe were always detected in these waters, others (Cr, Pb, Cu, Ni, V, Co) were not. Large variations in the water constituents' concentrations were observed, with Fe, Pb and V being the most variable ones. Concentrations of Zn and Cu in the run-off waters exceeded the values established by the Swedish environmental authorities in 100% and 97% of samples, respectively. The correlation analyses indicated TSS as a potential surrogate of Pb, V, Co, Ni, As, Ba, Cr and COD (0.949 > R > 0.808), making it reasonable to state that a treatment system with focus on TSS removal would also reduce toxic metals from these waters. The first-flush phenomenon was evident for most of the constituents. Significant differences (p < 0.05) in the first-flush magnitude of different run-off events were observed confirming that hydro-meteorological variables such as dry period, precipitation duration and average intensity play important roles. Metal loads originating from the log yard were mainly composed ofZn, Cu and Ba. Knowledge of the physicochemical characteristics, discharge dynamics and the storm variables involved in the process is a crucial step for the proposal and implementation of a stormwater management programme.
Effect of Intermediate Flush Using Different Devices to Prevent Chemical Smear Layer Formation.
Silva, Camilla Corrêa; Ferreira, Vivian Maria Durange; De-Deus, Gustavo; Herrera, Daniel Rodrigo; Prado, Maíra do; Silva, Emmanuel João Nogueira Leal da
2017-01-01
This study compared the effect of intermediate flush with distilled water delivered by conventional irrigation, EndoVac microcannula or Self-Adjusting File (SAF) system in the prevention of chemical smear layer (CSL) formation. Thirty human premolars were used. Canals were prepared with Reciproc system and 5.25% NaOCl. After chemomechanical preparation, samples were divided in 3 groups (n=10) according to the intermediate irrigation protocol with distilled water using: conventional irrigation, EndoVac microcannula or SAF. A final flush with 2% chlorhexidine solution was used and scanning electron microscopy was performed to assess protocol effectiveness. Two calibrated evaluators attributed scores according the presence or absence of CSL on the surface of the root canal walls at the coronal, middle and apical thirds, as follows: (1) no CSL; (2) small amounts of CSL; (3) moderate CSL; and (4) heavy CSL. Differences between protocols were analyzed with Kruskal-Wallis and Mann-Whitney U tests. Friedman and Wilcoxon signed rank tests were used for comparison between each root canal third. SAF resulted in less formation of CSL when compared with the conventional irrigation and EndoVac microcannula (p<0.05). When root canal thirds were analyzed, conventional irrigation and EndoVac groups showed less CSL formation at coronal and middle thirds in comparison to the apical third (p<0.05). In SAF group, there was no difference among the thirds (p>0.05). It may be concluded that an intermediate flush of distilled water, delivered by the SAF system resulted in a better reduction of CSL formation during chemomechanical preparation.
Chapotin, Saharah Moon; Razanameharizaka, Juvet H; Holbrook, N Michele
2006-01-01
Baobab trees (Adansonia, Bombacaceae) are widely thought to store water in their stems for use when water availability is low. We tested this hypothesis by assessing the role of stored water during the dry season in three baobab species in Madagascar. In the dry season, leaves are present only during and after leaf flush. We quantified the relative contributions of stem and soil water during this period through measures of stem water content, sap flow and stomatal conductance. Rates of sap flow at the base of the trunk were near zero, indicating that leaf flushing was almost entirely dependent on stem water. Stem water content declined by up to 12% during this period, yet stomatal conductance and branch sap flow rates remained very low. Stem water reserves were used to support new leaf growth and cuticular transpiration, but not to support stomatal opening before the rainy season. Stomatal opening coincided with the onset of sap flow at the base of the trunk and occurred only after significant rainfall.
Zushi, Yasuyuki; Masunaga, Shigeki
2009-08-01
Worldwide environmental pollution by perfluorinated compounds (PFCs) has been reported. PFCs have also been reported to have nonpoint sources (NPSs). A fixed-point hourly monitoring in the river was conducted during a storm event using an automatic sampler to estimate the impact of the first-flush of PFCs from NPS in this study. Perfluorocarboxylates (PFCAs) and perfluoroalkyl sulfonates (PFASs) with different chain lengths were monitored. The concentrations of short- to medium-chain-length PFCAs such as PFHpA, PFOA and PFNA, and PFASs such as PFBS, PFPeS, PFHxS, PFHpS and PFOS showed no marked increase with the storm-runoff event. However, in contrast to this, concentrations of long-chain-length PFCAs such as PFDA and PFUnA increased markedly. The concentrations of PFDA and PFUnA increased 3.4 (1.5-5.0 ng L(-1))- and 2.0 (3.3-6.7 ng L(-1))-fold, respectively. This study demonstrates that large loads of long-chain-length PFCAs are discharged to the Hayabuchi River during the first-flush after the rain event.
Katsiapi, Matina; Moustaka-Gouni, Maria; Michaloudi, Evangelia; Kormas, Konstantinos Ar
2011-10-01
Phytoplankton and water quality of Marathonas drinking-water Reservoir were examined for the first time. During the study period (July-September 2007), phytoplankton composition was indicative of eutrophic conditions although phytoplankton biovolume was low (max. 2.7 mm³ l⁻¹). Phytoplankton was dominated by cyanobacteria and diatoms, whereas desmids and dinoflagellates contributed with lower biovolume values. Changing flushing rate in the reservoir (up to 0.7% of reservoir's water volume per day) driven by water withdrawal and occurring in pulses for a period of 15-25 days was associated with phytoplankton dynamics. Under flushing pulses: (1) biovolume was low and (2) both 'good' quality species and the tolerant to flushing 'nuisance' cyanobacterium Microcystis aeruginosa dominated. According to the Water Framework Directive, the metrics of phytoplankton biovolume and cyanobacterial percentage (%) contribution indicated a moderate ecological water quality. In addition, the total biovolume of cyanobacteria as well as the dominance of the known toxin-producing M. aeruginosa in the reservoir's phytoplankton indicated a potential hazard for human health according to the World Health Organization.
Design and setup of intermittent-flow respirometry system for aquatic organisms.
Svendsen, M B S; Bushnell, P G; Steffensen, J F
2016-01-01
Intermittent-flow respirometry is an experimental protocol for measuring oxygen consumption in aquatic organisms that utilizes the best features of closed (stop-flow) and flow-through respirometry while eliminating (or at least reducing) some of their inherent problems. By interspersing short periods of closed-chamber oxygen consumption measurements with regular flush periods, accurate oxygen uptake rate measurements can be made without the accumulation of waste products, particularly carbon dioxide, which may confound results. Automating the procedure with easily available hardware and software further reduces error by allowing many measurements to be made over long periods thereby minimizing animal stress due to acclimation issues. This paper describes some of the fundamental principles that need to be considered when designing and carrying out automated intermittent-flow respirometry (e.g. chamber size, flush rate, flush time, chamber mixing, measurement periods and temperature control). Finally, recent advances in oxygen probe technology and open source automation software will be discussed in the context of assembling relatively low cost and reliable measurement systems. © 2015 The Fisheries Society of the British Isles.
Kwak, Jae; Fan, Maomian; Martin, Jennifer A; Ott, Darrin K; Grigsby, Claude C
2017-01-01
Gas sampling bags have been used for collecting air samples. Tedlar bags are most commonly used, but bleed background chemicals such as N,N-dimethylacetamide and phenol. It is often necessary to remove the contaminant by flushing the bags with pure nitrogen or air. In this study, we identified four chloroprene dimerization products as background contaminants emitted from ALTEF bags that are made of a proprietary polyvinylidene difluoride (PVDF). No monomer chloroprene was detected in the bags analyzed. All of the dimers gradually increased once bags were filled with nitrogen due to diffusion from the bag surface. Flushing the bags with nitrogen reduced their concentrations, but was not effective for removing the contaminants. When the bags that had been flushed with nitrogen 5 times were left for 24 h, they increased again, indicating that the dimers were constantly emitted from the ALTEF bag surface. To our knowledge, these compounds have never been demonstrated in ALTEF or other PVDF bags. Our finding indicates that ALTEF might be incorporated with Neoprene (chloroprene-based polymer) during its manufacturing process.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fowler, Kimberly M.; Kora, Angela R.
This report is a summary of the water analysis performance for the Denver, Colorado Wynkoop Building. The Wynkoop Building (Figure 1) was built in 2006 as the Environmental Protection Agency (EPA) Region 8 Headquarters intended to house over 900 occupants in the 301,292 gross square feet (248,849 rentable square feet). The building was built on a brownfield in the Lower Downtown Historic District as part of an urban redevelopment effort. The building was designed and constructed through a public-private partnership with the sustainable design elements developed jointly by General Services Administration (GSA) and EPA. That partnership is still active withmore » all parties still engaged to optimize building operations and use the building as a Learning Laboratory. The building design achieved U.S. Green Building Council Leadership in Energy and Environmental Design for New Construction (LEED-NC) Gold Certification in 2008 (Figure 2) and a 2008 EPA Energy Star Rating of 96 with design highlights that include: (1) Water use was designed to use 40% less than a typical design baseline. The design included low flow fixtures, waterless urinals and dual flush toilets; (2) Native and adaptive vegetation were selected to minimize the need for irrigation water for landscaping; and (3) Energy use intensity was modeled at 66.1 kBtus/gross square foot, which is 39% better than ASHRAE 90.1 1999. The Wynkoop Building water use (10 gallons/square foot) was measured at lower than industry average (15 gallons/square foot) and GSA goals (13 gallons/square foot), however, it was higher than building management expected it would be. The type of occupants and number of occupants can have a significant impact on fixture water use. The occupancy per floor varied significantly over the study time period, which added uncertainty to the data analysis. Investigation of the fixture use on the 2nd, 5th, and 7th floors identified potential for water use reduction if the flush direction of the dual-flush toilet handles was reversed. The building management retrofitted the building's toilets with handles that operated on reduced flush when pushed down (0.8 gallons) and full flush when pulled up (1.1 gallons). The water pressure on the 5th floor (< 30 psi) is less than half the pressure on the 7th floor (>80 psi). The measured water savings post-retrofit was lower on the 5th floor than the 7th floor. The differences in water pressure may have had an impact on the quantity of water used per floor. The second floor water use was examined prior to and following the toilet fixture retrofit. This floor is where conference rooms for non-building occupants are available for use, thus occupancy is highly variable. The 3-day average volume per flush event was higher post-retrofit (0.79 gallons per event), in contrast to pre-retrofit (0.57 gallons per event). There were 40% more flush events post retrofit, which impacted the findings. Water use in the third floor fitness center was also measured for a limited number of days. Because of water line accessibility, only water use on the men's side of the fitness center was measured and from that the total fitness center water use was estimated. Using the limited data collected, the fitness center shower water use is approximately 2% of the whole building water use. Overall water use in the Wynkoop Building is below the industry baseline and GSA expectations. The dual flush fixture replacement appears to have resulted in additional water savings that are expected to show a savings in the total annual water use.« less
FLUSH: A tool for the design of slush hydrogen flow systems
NASA Technical Reports Server (NTRS)
Hardy, Terry L.
1990-01-01
As part of the National Aerospace Plane Project an analytical model was developed to perform calculations for in-line transfer of solid-liquid mixtures of hydrogen. This code, called FLUSH, calculates pressure drop and solid fraction loss for the flow of slush hydrogen through pipe systems. The model solves the steady-state, one-dimensional equation of energy to obtain slush loss estimates. A description of the code is provided as well as a guide for users of the program. Preliminary results are also presented showing the anticipated degradation of slush hydrogen solid content for various piping systems.
Early intervention reduces morbidity in extravasation injuries from 'lighter fuel' injection.
Thaha, M A; McKinnell, T H; Graham, K E; Naasan, A N
2007-01-01
Injection of 'lighter fuel' with suicidal intent is rare. Extravasation of the chemical may rarely cause systemic toxicity, but usually it results in extensive soft tissue damage. Such injuries when managed by the traditional expectant policy are associated with considerable morbidity. Early aggressive surgical management using 'saline flush out' limits the tissue damage by stopping the natural progression of the chemical mediated injury and the subsequent inflammatory response, thereby allowing better skin preservation and functional outcome in these cases. We report a case of 'lighter fuel' subcutaneous extravasation injury managed by 'saline flush out' technique soon after presentation.
Water footbath, automatic flushing, and disinfection to improve the health of bovine feet.
Fjeldaas, T; Knappe-Poindecker, M; Bøe, K E; Larssen, R B
2014-05-01
Disinfecting footbaths are used to treat and prevent interdigital dermatitis (ID) and heel horn erosion (HHE). However, many disinfectants are disadvantageous for the environment and, as an alternative, washing of the feet has been introduced. Our aim was to investigate the effect of water footbaths (trial 1), footbaths with CuSO4 (trial 2), automatic water flushing (trial 3), and water flushing followed by disinfection with a glutaraldehyde-based compound (trial 4) in 4 randomized controlled clinical trials performed in a freestall dairy herd of approximately 45 Norwegian Red cows. At trimming before and after each trial, hind foot diseases, hardness of the claw horn (in D-units), locomotion, and cleanliness of the claws were recorded. Before each trial, the cows were divided in comparable study and control groups, based on prevalence of ID and HHE, parity, and days in milk. Using a transponder-regulated gate, the study groups were led through a footbath (trials 1 and 2) or an automatic washer (trials 3 and 4), whereas the control groups were left untreated. Each trial lasted 3 mo and the curative effect in diseased cows and the preventive effect in cows with healthy feet on ID, HHE, and ID + HHE were analyzed. In trial 2, a preventive effect of CuSO4 on HHE compared with the untreated cows was observed. During trial 1, 100% (11/11) of the treated cows with ID got better and 22% (2/9) without ID became diseased, whereas 92% (11/12) of the treated cows with ID + HHE got better and 38% (3/8) without ID + HHE became diseased. During trial 2, 69% (9/13) of the treated cows with ID got better and 11% (1/9) without ID became diseased. During trial 4, 19% (3/16) of the untreated cows with ID + HHE got better and 71% (5/7) without ID + HHE became diseased. In trial 3, no significant effects on ID, HHE, or ID + HHE were revealed. In trial 2 (CuSO4), the treated cows' claw horn was harder after the trial compared with the controls (D-unit difference: 13.25). In trial 3 (stationary water flushing) the treated cows' claw horn was softer after the trial when compared with the controls (D-unit difference: -15.66). The CuSO4 footbaths were useful to prevent HHE and indicate that automatic stationary flushing with only water had no beneficial effect on ID or HHE. The claw horn of cows walking through CuSO4 became harder and the claw horn of cows that had their hind feet flushed with water became softer compared with the controls. Copyright © 2014 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Sis Çelik, A; Pasinlioğlu, T
2017-02-01
The aim of the present study was to determine the effect of imparting planned health education to climacteric women on their beliefs related to hot flushes and on their quality of life. The research was conducted using pretest and post-test semi-experimental models along with a control group. Of 450 women, 255 were randomly selected and invited to participate in the study. Five people did not agree to participate in the study. Three people were also excluded from the study because they did not complete training. The research sample was comprised of 247 climacteric women (121 women in the experimental group and 126 women in the control group) who were <65 years (the average ages of the participants in the experimental group were 50.61 ± 5.54 years and in the control group 50.94 ± 6.03 years), had experienced hot flushes within the past month, were going through the menopause and postmenopause, were not using hormone replacement therapy, and had agreed to participate in the study. Participants were asked to complete a Sociodemographic Questionnaire, the Hot Flush Beliefs Scale, and The Menopause-Specific Quality of Life Questionnaire. Three educational sessions at 2-week intervals were given to the women in the experimental group. The research was supported with an educational booklet prepared by the researchers. Training was not given to the women in the control group. After the education of the experimental group (after about 6 months), women in both groups recompleted the data collection forms, and post-test data were collected. On all the subscales, the total of the Hot Flush Beliefs Scale, and the average post-test score, the women in the experimental group scored lower than the women in the control group (the average post-test total score in the experimental group was 26.22 ± 10.09 and in control group it was 52.25 ± 15.04; p < 0.001). While the women in the experimental group developed positive beliefs about their hot flushes, the beliefs of the women in the control group remained unchanged. The average post-test score on all the subscales of the Menopause-Specific Quality of Life Questionnaire for the women in the experimental group was lower than that for the women in the control group (p < 0.001; the average post-test score in the experimental group for the vasomotor subscale was 1.78 ± 0.88, for the psychosocial subscale 1.50 ± 0.75, for the physical subscale 1.69 ± 0.63, and for the sexual subscale 2.91 ± 2.06; the average post-test score in the control group for the the vasomotor subscale was 3.80 ± 1.88, for the psychosocial subscale 2.79 ± 1.08, for the physical subscale 3.10 ± 1.04, and for the sexual subscale 2.25 ± 2.11). While the quality of life of the women in the experimental group showed an upward trend, that of the women in the control group remained the same. It was found that planned health education about the climacteric period reduced women's negative beliefs about hot flushes and enhanced their quality of life.
Carbon utilization by fruit limits shoot growth in alternate-bearing citrus trees.
Martínez-Alcántara, Belén; Iglesias, Domingo J; Reig, Carmina; Mesejo, Carlos; Agustí, Manuel; Primo-Millo, Eduardo
2015-03-15
Fruit load in alternate-bearing citrus trees is reported to alter shoot number and growth during spring, summer, and autumn flushes, and the source-sink balance, which affects the storage and mobilization of reserve nutrients. The aim of this work was to assess the extent of shoot growth inhibition resulting from the presence of fruits in 'Moncada' mandarin trees loaded with fruit (ON) or with very light fruit load (OFF), and to identify the role of carbohydrates and nitrogenous compounds in the competition between fruits and shoots. Growth of reproductive and vegetative organs was measured on a monthly basis. (13)C- and (15)N-labeled compounds were supplied to trace the allocation of reserve nutrients and subsequent translocation from source to sink. At the end of the year, OFF trees produced more abundant flushes (2.4- and 4.9-fold higher in number and biomass, respectively) than ON trees. Fruits from ON trees accumulated higher C amounts at the expense of developing flushes, whereas OFF trees exhibited the opposite pattern. An inverse relationship was identified between the amount of C utilized by fruits and vegetative flush growth. (13)C-labeling revealed an important role for mature leaves of fruit-bearing branches in supporting shoot/fruit growth, and the elevated sink strength of growing fruits on shoots. N availability for vegetative shoots was not affected by the presence or absence of fruits, which accumulated important amounts of (15)N. In conclusion, our results show that shoot growth is resource-limited as a consequence of fruit development, and vegetative-growth inhibition is caused by photoassimilate limitation. The competence for N is not a decisive factor in limiting vegetative growth under the experimental conditions of this study. Copyright © 2014 Elsevier GmbH. All rights reserved.
Fine Sediment Residency in Streambeds in Southeastern Australia.
NASA Astrophysics Data System (ADS)
Croke, J. C.; Thompson, C. J.; Rhodes, E.
2007-12-01
A detailed understanding of channel forming and maintenance processes in streams requires some measurement and/or prediction of bed load transport and sediment mobility. Traditional field based measurements of such processes are often problematic due to the high discharge characteristics of upland streams. In part to compensate for such difficulties, empirical flow competence equations have also been developed to predict armour or bedform stabilising grain mobility. These equations have been applied to individual reaches to predict the entrainment of a threshold grain size and the vertical extent of flushing. In cobble- and boulder-bed channels the threshold grain size relates to the size of the bedform stabilising grains (eg. D84, D90). This then allows some prediction of when transport of the matrix material occurs. The application of Optically Stimulated Luminescence (OSL) dating is considered here as an alternative and innovative way to determine fine sediment residency times in stream beds. Age estimates derived from the technique are used to assist in calibrating sediment entrainment models to specific channel types and hydrological regimes. The results from a one-dimensional HEC-RAS model indicate that recurrence interval floods exceeding bankfull up to 13 years are competent to mobilise the maximum overlying surface grain sizes at the sites. OSL minimum age model results of well bleached quartz in the fine matrix particles are in general agreement with selected competence equation predictions. The apparent long (100-1400y) burial age of most of the mineral quartz suggests that competent flows are not able to flush all subsurface fine-bed material. Maximum bed load exchange (flushing) depth was limited to twice the depth of the overlying D90 grain size. Application of OSL in this study provides important insight into the nature of matrix material storage and flushing in mountain streams.
Analytical scaling relations to evaluate leakage and intrusion in intermittent water supply systems.
Taylor, David D J; Slocum, Alexander H; Whittle, Andrew J
2018-01-01
Intermittent water supplies (IWS) deliver piped water to one billion people; this water is often microbially contaminated. Contaminants that accumulate while IWS are depressurized are flushed into customers' homes when these systems become pressurized. In addition, during the steady-state phase of IWS, contaminants from higher-pressure sources (e.g., sewers) may continue to intrude where pipe pressure is low. To guide the operation and improvement of IWS, this paper proposes an analytic model relating supply pressure, supply duration, leakage, and the volume of intruded, potentially-contaminated, fluids present during flushing and steady-state. The proposed model suggests that increasing the supply duration may improve water quality during the flushing phase, but decrease the subsequent steady-state water quality. As such, regulators and academics should take more care in reporting if water quality samples are taken during flushing or steady-state operational conditions. Pipe leakage increases with increased supply pressure and/or duration. We propose using an equivalent orifice area (EOA) to quantify pipe quality. This provides a more stable metric for regulators and utilities tracking pipe repairs. Finally, we show that the volume of intruded fluid decreases in proportion to reductions in EOA. The proposed relationships are applied to self-reported performance indicators for IWS serving 108 million people described in the IBNET database and in the Benchmarking and Data Book of Water Utilities in India. This application shows that current high-pressure, continuous water supply targets will require extensive EOA reductions. For example, in order to achieve national targets, utilities in India will need to reduce their EOA by a median of at least 90%.
Jet stability and wall impingement flow field in a thermal striping experiment
Lomperski, S.; Obabko, A.; Merzari, E.; ...
2017-08-10
We present velocity and temperature field measurements for a 0.9 x 0.9 x 1.7 m glass tank in which two air jets at Re=10000 mix and impinge upon the lid at ambient temperature and pressure. Flow patterns are characterized across a 350 x 200 mm plane located 3 mm below the lid for two inlet geometries: 1) “extended”, in which inlet channels protrude above the tank base, and 2) “flush”, a flat base without protrusions. This minor geometry variation produced distinct changes in the lid flow field, appearing as three stagnant regions for the extended case and only one formore » flush. The dichotomy is attributed to system stability characteristics: jets are stable in the extended case and unstable for flush. In a separate set of nonisothermal tests, the impingement temperature field was measured for inlet temperature mismatches of 4 oC and jets near Re=10000. A 50 m-long fiber optic distributed temperature sensor positioned 2 mm below the lid measured at 1350 locations. Like the velocity fields, the temperature fields differ for the two inlet geometries: good thermal mixing for the flush case and subdued mixing for the extended case. Simulations with the spectral element code Nek5000 replicated the observed stability dichotomy, duplicating the number of stagnant regions observed in the experiment and matching their locations within ±10 mm. Simulation data suggests that flush case instability is due to interactions between jets and wall flows at the bottom of the tank. The clear flow dichotomy exhibited by this two-jet setup presents an unambiguous case to test the ability of CFD tools to predict subtle flow field changes driven by minor modifications in geometry in the context of thermal striping.« less
Reversible adsorption and flushing of arsenic in a shallow, Holocene aquifer of Bangladesh
Radloff, Kathleen A.; Zheng, Yan; Stute, Martin; Weinman, Beth; Bostick, Benjamin; Mihajlov, Ivan; Bounds, Margaret; Rahman, M. Moshiur; Huq, M. Rezaul; Ahmed, Kazi M.; Schlosser, Peter; van Geen, Alexander
2015-01-01
The spatial heterogeneity of dissolved arsenic (As) concentrations in shallow groundwater of the Bengal Basin has been attributed to transport of As (and reactive carbon) from external sources or to the release of As from within grey sand formations. We explore the latter scenario in this detailed hydrological and geochemical study along a 300 m transect of a shallow aquifer extending from a groundwater recharge area within a sandy channel bar to its discharge into a nearby stream. Within the 10–20 m depth range, groundwater ages along the transect determined by the 3H–3He method increase from <10 yr in the recharge area to a maximum of 40 yr towards the stream. Concentrations of groundwater As within the same grey sands increase from 10 to 100 to ∼500 µg/L along this transect. Evidence of reversible adsorption of As between the groundwater and sediment was obtained from a series of push–pull experiments, traditional batch adsorption experiments, and the accidental flooding of a shallow monitoring well. Assuming reversible adsorption and a distribution coefficient, Kd, of 0.15–1.5 L/kg inferred from these observations, a simple flushing model shows that the increase in As concentrations with depth and groundwater age at this site, and at other sites in the Bengal and Red River Basins, can be attributed to the evolution of the aquifer over 100–1000 years as aquifer sands are gradually flushed of their initial As content. A wide range of As concentrations can thus be maintained in groundwater with increases with depth governed by the history of flushing and local recharge rates, without external inputs of reactive carbon or As from other sources. PMID:28458447
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jensenius, J.; Munksgaard, N.C.
Fracture filling calcite from the piercement fields of East Rosa, Skjold, Rolf, North Arne, Nils and Vagn and the dome field Dan have been studied by fluorescence and cathodoluminescence microscopy, fluid inclusion microthermometry and carbon and oxygen isotopes. The carbon and oxygen isotope compositions of the reservoir matrix chalk have also been measured. The temperature estimates obtained from fluid inclusion data suggest that the fracture filling calcite of the piercement fields precipitated during hot water flushing of the reservoirs. The flushing system only existed around the salt diapirs and was probably related to expulsion of overpressured fluid from the surroundingmore » sediments. The thermal anomaly and the faults associated with the diapirs probably were important factors in focusing the ascending water. Lower {delta}{sup 18}O values with shallower depth of burial suggest that the porosity of chalk in the shallower fields was more severely reduced by calcite cementation during the flushing event than in the deeper fields. In the case of North Arne, Nils, Vagn and Dan, {delta}{sup 13}C values of the fracture filling calcites are similar to those of normal chalk (0.5 to 3.5 {per thousand}). However, calcites from Rolf, Skjold and East Rosa are depleted by {minus}1.8, {minus}6.2 and {minus}16.7 {per thousand}, respectively. Only in East Rosa is the matrix chalk itself depleted in {sup 13}C. The low {delta}{sup 13}C values are interpreted as the result of biodegradation. Sulfate originating from the underlying diapirs was flushed into the reservoir and used by bacteria to degrade present hydrocarbons. This process produced {sup 13}c depleted bicarbonate which was incorporated into the fracture-filling calcites.« less
Characterization and first flush analysis in road and roof runoff in Shenyang, China.
Li, Chunlin; Liu, Miao; Hu, Yuanman; Gong, Jiping; Sun, Fengyun; Xu, Yanyan
2014-01-01
As urbanization increases, urban runoff is an increasingly important component of total urban non-point source pollution. In this study, the properties of urban runoff were examined in Shenyang, in northeastern China. Runoff samples from a tiled roof, a concrete roof and a main road were analyzed for key pollutants (total suspended solids (TSS), total nitrogen (TN), total phosphorus (TP), chemical oxygen demand (COD), Pb, Cd, Cr, Cu, Ni, and Zn). The event mean concentration, site mean concentration, M(V) curves (dimensionless cumulative curve of pollutant load with runoff volume), and mass first flush ratio (MFF30) were used to analyze the characteristics of pollutant discharge and first flush (FF) effect. For all events, the pollutant concentration peaks occurred in the first half-hour after the runoff appeared and preceded the flow peaks. TN is the main pollutant in roof runoff. TSS, TN, TP, Pb, and Cr are the main pollutants in road runoff in Shenyang. There was a significant correlation between TSS and other pollutants except TN in runoff, which illustrated that TSS was an important carrier of organic matter and heavy metals. TN had strong positive correlations with total rainfall (Pearson's r = 0.927), average rainfall (Pearson's r = 0.995), and maximum rainfall intensity (Pearson's r = 0.991). TP had a strong correlation with rainfall intensity (Pearson's r = 0.940). A significant positive correlation between COD and rainfall duration (Pearson's r = 0.902, significance level = 0.05) was found. The order of FF intensity in different surfaces was concrete roof > tile roof > road. Rainfall duration and the length of the antecedent dry period were positively correlated with the FF. TN tended to exhibit strong flush for some events. Heavy metals showed a substantially stronger FF than other pollutant.
Large-Eddy Simulation of Coherent Flow Structures within a Cubical Canopy
NASA Astrophysics Data System (ADS)
Inagaki, Atsushi; Castillo, Marieta Cristina L.; Yamashita, Yoshimi; Kanda, Manabu; Takimoto, Hiroshi
2012-02-01
Instantaneous flow structures "within" a cubical canopy are investigated via large-eddy simulation. The main topics of interest are, (1) large-scale coherent flow structures within a cubical canopy, (2) how the structures are coupled with the turbulent organized structures (TOS) above them, and (3) the classification and quantification of representative instantaneous flow patterns within a street canyon in relation to the coherent structures. We use a large numerical domain (2,560 m × 2,560 m × 1,710 m) with a fine spatial resolution (2.5 m), thereby simulating a complete daytime atmospheric boundary layer (ABL), as well as explicitly resolving a regular array of cubes (40 m in height) at the surface. A typical urban ABL is numerically modelled. In this situation, the constant heat supply from roof and floor surfaces sustains a convective mixed layer as a whole, but strong wind shear near the canopy top maintains the surface layer nearly neutral. The results reveal large coherent structures in both the velocity and temperature fields "within" the canopy layer. These structures are much larger than the cubes, and their shapes and locations are shown to be closely related to the TOS above them. We classify the instantaneous flow patterns in a cavity, specifically focusing on two characteristic flow patterns: flushing and cavity-eddy events. Flushing indicates a strong upward motion, while a cavity eddy is characterized by a dominant vortical motion within a single cavity. Flushing is clearly correlated with the TOS above, occurring frequently beneath low-momentum streaks. The instantaneous momentum and heat transport within and above a cavity due to flushing and cavity-eddy events are also quantified.
Dynamics of Biofilm Regrowth in Drinking Water Distribution Systems.
Douterelo, I; Husband, S; Loza, V; Boxall, J
2016-07-15
The majority of biomass within water distribution systems is in the form of attached biofilm. This is known to be central to drinking water quality degradation following treatment, yet little understanding of the dynamics of these highly heterogeneous communities exists. This paper presents original information on such dynamics, with findings demonstrating patterns of material accumulation, seasonality, and influential factors. Rigorous flushing operations repeated over a 1-year period on an operational chlorinated system in the United Kingdom are presented here. Intensive monitoring and sampling were undertaken, including time-series turbidity and detailed microbial analysis using 16S rRNA Illumina MiSeq sequencing. The results show that bacterial dynamics were influenced by differences in the supplied water and by the material remaining attached to the pipe wall following flushing. Turbidity, metals, and phosphate were the main factors correlated with the distribution of bacteria in the samples. Coupled with the lack of inhibition of biofilm development due to residual chlorine, this suggests that limiting inorganic nutrients, rather than organic carbon, might be a viable component in treatment strategies to manage biofilms. The research also showed that repeat flushing exerted beneficial selective pressure, giving another reason for flushing being a viable advantageous biofilm management option. This work advances our understanding of microbiological processes in drinking water distribution systems and helps inform strategies to optimize asset performance. This research provides novel information regarding the dynamics of biofilm formation in real drinking water distribution systems made of different materials. This new knowledge on microbiological process in water supply systems can be used to optimize the performance of the distribution network and to guarantee safe and good-quality drinking water to consumers. Copyright © 2016 Douterelo et al.
Analytical scaling relations to evaluate leakage and intrusion in intermittent water supply systems
Slocum, Alexander H.; Whittle, Andrew J.
2018-01-01
Intermittent water supplies (IWS) deliver piped water to one billion people; this water is often microbially contaminated. Contaminants that accumulate while IWS are depressurized are flushed into customers’ homes when these systems become pressurized. In addition, during the steady-state phase of IWS, contaminants from higher-pressure sources (e.g., sewers) may continue to intrude where pipe pressure is low. To guide the operation and improvement of IWS, this paper proposes an analytic model relating supply pressure, supply duration, leakage, and the volume of intruded, potentially-contaminated, fluids present during flushing and steady-state. The proposed model suggests that increasing the supply duration may improve water quality during the flushing phase, but decrease the subsequent steady-state water quality. As such, regulators and academics should take more care in reporting if water quality samples are taken during flushing or steady-state operational conditions. Pipe leakage increases with increased supply pressure and/or duration. We propose using an equivalent orifice area (EOA) to quantify pipe quality. This provides a more stable metric for regulators and utilities tracking pipe repairs. Finally, we show that the volume of intruded fluid decreases in proportion to reductions in EOA. The proposed relationships are applied to self-reported performance indicators for IWS serving 108 million people described in the IBNET database and in the Benchmarking and Data Book of Water Utilities in India. This application shows that current high-pressure, continuous water supply targets will require extensive EOA reductions. For example, in order to achieve national targets, utilities in India will need to reduce their EOA by a median of at least 90%. PMID:29775462
Li, Chi-Wang; Chiu, Chun-Hao; Lee, Yu-Cheng; Chang, Chia-Hao; Lee, Yu-Hsun; Chen, Yi-Ming
2010-01-01
In our previous publications, compressed air-assisted solvent extraction process (CASX) was developed and proved to be kinetically efficient process for metal removal. In the current study, CASX with a ceramic MF membrane integrated for separation of spent solvent was employed to remove and recover metal from wastewater. MF was operated either in crossflow mode or dead-end with intermittent flushing mode. Under crossflow mode, three distinct stages of flux vs. TMP (trans-membrane pressure) relationship were observed. In the first stage, flux increases with increasing TMP which is followed by the stage of stable flux with increasing TMP. After reaching a threshold TMP which is dependent of crossflow velocity, flux increases again with increasing TMP. At the last stage, solvent was pushed through membrane pores as indicated by increasing permeate COD. In dead-end with intermittent flushing mode, an intermittent flushing flow (2 min after a 10-min or a 30-min dead-end filtration) was incorporated to reduce membrane fouling by flush out MSAB accumulated on membrane surface. Effects of solvent concentration and composition were also investigated. Solvent concentrations ranging from 0.1 to 1% (w/w) have no adverse effect in terms of membrane fouling. However, solvent composition, i.e. D(2)EHPA/kerosene ratio, shows impact on membrane fouling. The type of metal extractants employed in CASX has significant impact on both membrane fouling and the quality of filtrate due to the differences in their viscosity and water solubility. Separation of MSAB was the limiting process controlling metal removal efficiency, and the removal efficiency of Cd(II) and Cr(VI) followed the same trend as that for COD.
NASA Astrophysics Data System (ADS)
Qiu, Liming; Shen, Rongxi; Song, Dazhao; Wang, Enyuan; Liu, Zhentang; Niu, Yue; Jia, Haishan; Xia, Shankui; Zheng, Xiangxin
2017-12-01
An accurate and non-destructive evaluation method for the hydraulic measure impact range in coal seams is urgently needed. Aiming at the application demands, a theoretical study and field test are presented using the direct current (DC) method to evaluate the impact range of coal seam hydraulic measures. We firstly analyzed the law of the apparent resistivity response of an abnormal conductive zone in a coal seam, and then investigated the principle of non-destructive testing of the coal seam hydraulic measure impact range using the DC method, and used an accurate evaluation method based on the apparent resistivity cloud chart. Finally, taking hydraulic fracturing and hydraulic flushing as examples, field experiments were carried out in coal mines to evaluate the impact ranges. The results showed that: (1) in the process of hydraulic fracturing, coal conductivity was enhanced by high-pressure water in the coal seam, and after hydraulic fracturing, the boundary of the apparent resistivity decrease area was the boundary impact range. (2) In the process of hydraulic flushing, coal conductivity was reduced by holes and cracks in the coal seam, and after hydraulic flushing, the boundary of the apparent resistivity increase area was the boundary impact range. (3) After the implementation of the hydraulic measures, there may be some blind zones in the coal seam; in hydraulic fracturing blind zones, the apparent resistivity increased or stayed constant, while in hydraulic flushing blind zones, the apparent resistivity decreased or stayed constant. The DC method realized a comprehensive and non-destructive evaluation of the impact range of the hydraulic measures, and greatly reduced the time and cost of evaluation.
Raymond, Prosper; Mshandete, Anthony Manoni; Kajumulo Kivaisi, Amelia
2015-01-01
The activity of oxidative and hydrolytic enzymes of the edible and medicinal white rot fungi Coprinus cinereus (Schaeff.) Gray mushroom was observed during mycelia growth and fruiting body development in solid substrate fermentation using sisal waste fractions amended with cow dung manure as supplement. Laccase had the highest titre value among the five detected enzymes. Its activity was higher during mycelia growth compared to fruiting phase, with 10% supplemented substrate formulation unmixed sisal leaf decortication residues [abbreviated SL : SB (100 : 0)] displaying the highest activity of 39.45 ± 12.05 Ug−1. Lignin peroxidase (LiP) exhibited a characteristic wave-like pattern with the highest peaks found either during full mycelia colonization or soon after first flush harvest; the highest activity of 1.93 ± 0.62 Ug−1 was observed on unsupplemented SL : SB (100 : 0) substrate formulation during mycelia colonization. For hydrolytic enzymes, the highest carboxymethyl cellulase (CMCase) activity of 2.03 ± 0.70 Ug−1 was observed on 20% supplemented SL : SB (0 : 100) after first flush; that of pectinase (1.90 ± 0.32 Ug−1) was revealed after third flush on 10% supplemented SL : SB (0 : 100) substrate formulation while 10% supplemented SL : SB (25 : 75) exhibited the highest xylanase activity (1.23 ± 0.12 Ug−1) after first flush. These findings show that the activities of both oxidative and hydrolytic enzymes were regulated in line with developmental phase of growth of Coprinus cinereus. PMID:26664748
Jet stability and wall impingement flow field in a thermal striping experiment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lomperski, S.; Obabko, A.; Merzari, E.
We present velocity and temperature field measurements for a 0.9 x 0.9 x 1.7 m glass tank in which two air jets at Re=10000 mix and impinge upon the lid at ambient temperature and pressure. Flow patterns are characterized across a 350 x 200 mm plane located 3 mm below the lid for two inlet geometries: 1) “extended”, in which inlet channels protrude above the tank base, and 2) “flush”, a flat base without protrusions. This minor geometry variation produced distinct changes in the lid flow field, appearing as three stagnant regions for the extended case and only one formore » flush. The dichotomy is attributed to system stability characteristics: jets are stable in the extended case and unstable for flush. In a separate set of nonisothermal tests, the impingement temperature field was measured for inlet temperature mismatches of 4 oC and jets near Re=10000. A 50 m-long fiber optic distributed temperature sensor positioned 2 mm below the lid measured at 1350 locations. Like the velocity fields, the temperature fields differ for the two inlet geometries: good thermal mixing for the flush case and subdued mixing for the extended case. Simulations with the spectral element code Nek5000 replicated the observed stability dichotomy, duplicating the number of stagnant regions observed in the experiment and matching their locations within ±10 mm. Simulation data suggests that flush case instability is due to interactions between jets and wall flows at the bottom of the tank. The clear flow dichotomy exhibited by this two-jet setup presents an unambiguous case to test the ability of CFD tools to predict subtle flow field changes driven by minor modifications in geometry in the context of thermal striping.« less
Zhang, Hai-Han; Chen, Sheng-Nan; Huang, Ting-Lin; Shang, Pan-Lu; Yang, Xiao; Ma, Wei-Xing
2015-01-01
The growth of the bacterial community harbored in indoor drinking water taps is regulated by external environmental factors, such as indoor temperature. However, the effect of indoor heating on bacterial regrowth associated with indoor drinking water taps is poorly understood. In the present work, flow cytometry and community-level sole-carbon-source utilization techniques were combined to explore the effects of indoor heating on water bacterial cell concentrations and community carbon metabolic profiles in building tap pipes during the winter season. The results showed that the temperature of water stagnated overnight (“before”) in the indoor water pipes was 15–17 °C, and the water temperature decreased to 4–6 °C after flushing for 10 min (“flushed”). The highest bacterial cell number was observed in water stagnated overnight, and was 5–11 times higher than that of flushed water. Meanwhile, a significantly higher bacterial community metabolic activity (AWCD590nm) was also found in overnight stagnation water samples. The significant “flushed” and “taps” values indicated that the AWCD590nm, and bacterial cell number varied among the taps within the flushed group (p < 0.01). Heatmap fingerprints and principle component analyses (PCA) revealed a significant discrimination bacterial community functional metabolic profiles in the water stagnated overnight and flushed water. Serine, threonine, glucose-phosphate, ketobutyric acid, phenylethylamine, glycerol, putrescine were significantly used by “before” water samples. The results suggested that water stagnated at higher temperature should be treated before drinking because of bacterial regrowth. The data from this work provides useful information on reasonable utilization of drinking water after stagnation in indoor pipes during indoor heating periods. PMID:26516885
Meurisse, Nicolas; Pirenne, Jacques; Monbaliu, Diethard
2017-01-01
Non-anastomotic biliary strictures (NAS) represent a major cause of morbidity, graft loss, and mortality after liver transplantation (LTx). NAS can result from an ischemic/immune-mediated injury, or from the cytotoxic effect that bile salts have on the biliary mucosa under hypothermic conditions. For this reason it is crucial to flush the bile duct at the time of procurement. We report a case of an imported liver with an accidentally ligated and subsequently completely unflushed common bile duct. The recipient was a 60 year-old man suffering from hepatocellular carcinoma and post-alcoholic cirrhosis. Post-operative course was uneventful and the patient was discharged after 18days. Within 2 months post-transplantation, a rapidly evolving cholestasis was diagnosed. Endoscopic-retrograde-cholangio-pancreaticography revealed diffuse NAS. Due to the rapid clinical and biochemical deterioration there was no other option than re-transplantation. Suboptimally flushed bile ducts are often encountered and represent a risk factor for NAS after LTx. This unique case represented an extreme form where the biliary tree was not flushed at all. The dilemma of this unforeseen situation raised the question to transplant or discard this liver for transplantation? Given the organ shortage, the pressure to use less-than-ideal organs, the otherwise normal aspect of the liver and our incapacity to predict with certainty the development (or not) of NAS, we accepted this liver for transplantation. This case illustrates a contrario the importance of flushing the bile duct and risk of extensive dissection of the hepatic hilum at the time of procurement. Copyright © 2017 The Author(s). Published by Elsevier Ltd.. All rights reserved.
Everson, Matthew; Webber, Lucy; Penfold, Chris; Shah, Sanjoy; Freshwater-Turner, Dan
2016-11-01
We assessed the impact of heparinised saline versus 0.9% normal saline on arterial line patency. Maintaining the patency of arterial lines is essential for obtaining accurate physiological measurements, enabling blood sampling and minimising line replacement. Use of heparinised saline is associated with risks such as thrombocytopenia, haemorrhage and mis-selection. Historical studies draw variable conclusions but suggest that normal saline is at least as effective at maintaining line patency, although recent evidence has questioned this. We conducted a prospective analysis of the use of heparinised saline versus normal saline on unselected patients in the intensive care of our hospital. Data concerning duration of 471 lines insertion and reason for removal was collected. We found a higher risk of blockage for lines flushed with normal saline compared with heparinised saline (RR = 2.15, 95% CI 1.392-3.32, p ≤ 0.001). Of the 56 lines which blocked initially (19 heparinised saline and 37 normal saline lines), 16 were replaced with new lines; 5 heparinised saline lines and 11 normal saline lines were reinserted; 5 of these lines subsequently blocked again, 3 of which were flushed with normal saline. Our study demonstrates a clinically important reduction in arterial line longevity due to blockages when flushed with normal saline compared to heparinised saline. We have determined that these excess blockages have a significant clinical impact with further lines being inserted after blockage, resulting in increased risks to patients, wasted time and cost of resources. Our findings suggest that the current UK guidance favouring normal saline flushes should be reviewed.
Mena Ramírez, Esperanza; Villaseñor Camacho, José; Rodrigo, Manuel A; Cañizares, Pablo
2015-11-15
The aim of this work is to compare different strategies based on electrokinetic soil flushing and bioremediation for the remediation of diesel-polluted soil. Four options were tested at the laboratory scale: single bioremediation (Bio), performed as a control test; a direct combination of electrokinetic soil flushing and biological technologies (EKSF-Bio); EKSF-Bio with daily polarity reversal of the electric field (PR-EKSF-Bio); and a combination of electrokinetic soil flushing and a permeable reactive biological barrier (EKSF-BioPRB). Four batch experiments of 14 days duration were carried out for comparing technologies at room temperature with an electric field of 1.0 V cm(-1) (in EKSF). A diesel degrading microbial consortium was used. The experimental procedure and some specific details, such as the flushing fluids used, varied depending on the strategy. When using the EKSF-Bio option, a high buffer concentration was required to control the pH, causing soil heating, which negatively affected the biological growth and thus the diesel removal. The PR-EKSF-Bio and the EKSF-BioPRB options attained suitable operating conditions and improved the transport processes for biological growth. Polarity reversal was an efficient option for pH, moisture and temperature control. Homogeneous microbial growth was observed, and approximately 20% of the diesel was removed. The BioPRB option was not as efficient as PR-EKSF-Bio in controlling the operating conditions, but the central biobarrier protected the biological activity. Microbial growth was observed not only in the biobarrier but also in a large portion of the soil, and 29% of the diesel was removed in the short remediation test. Copyright © 2015 Elsevier B.V. All rights reserved.
Gilly, H; Weindlmayr-Goettel, M; Köberl, G; Steinbereithner, K
1992-10-01
The amounts of halothane and isoflurane trapped after exposure for up to 3 h at 2 MAC in commonly used anaesthesia circuit tubing were quantitated by gas chromatography. The decontaminating effects of procedures such as flushing with oxygen, thermal disinfection and/or routine storage were assessed in a similar way. After halothane exposure, anaesthetic content was highest in silicone (398 +/- 55 mg 100 g-1). Lower quantities were found in all other tubings investigated (electrically conductive latex: 64 +/- 4, conductive rubber: 62 +/- 4, polyethylene-vinyl-acetate (PEVA): 293 +/- 10 and 149 +/- 17 for non-conductive corrugated and spiral tubes, respectively, polysulfone (Hytrel): 155 +/- 10 mg 100 g-1). The isoflurane contents were substantially lower (silicone: 278 +/- 23; others: 55 +/- 7, 61 +/- 6, 163 +/- 9 and 86 +/- 8, 74 +/- 4 mg 100 g-1). The tubings' content did not correlate with the material's partition coefficient as full saturation was not achieved during exposure. Decontamination procedures reduced the content of volatile anaesthetics to a variable extent. Conductive latex and rubber showed the highest residual content, even after thermal disinfection and subsequent storage. Twenty-minute flushing with oxygen (8 l min-1) decreased effluent gas concentrations below 5 p.p.m. in all tubings. With silicone, after 1 h flushing, halothane concentrations still exceeded 10 p.p.m. (isoflurane: 8 p.p.m.). It is concluded that urgent decontamination by a 20-min flush warrants the safe re-use of previously 'contaminated' conductive rubber and latex as well as polysulfone tubings in critical situations, e.g. in malignant hyperthermia patients if disposable tubing is not immediately available.(ABSTRACT TRUNCATED AT 250 WORDS)
Influence of indigenous and added iron on copper extraction from soil.
Di Palma, Luca
2009-10-15
Experimental tests of copper leaching from a low permeability soil are presented and discussed. The objective of the experiments was to investigate the influence of indigenous and added iron in the soil towards copper mobilization. Metals' leaching was performed by flushing (column tests) or washing (batch tests) the soil with an aqueous solution of ethylenediaminetetraacetic acid, EDTA. An excess of EDTA was used in flushing tests (up to a EDTA:Cu molar ratio of about 26.2:1), while, in washing tests, the investigated EDTA vs. copper molar ratios were in the range between 1 (equimolar tests) and 8. Copper extraction yield in flushing tests (up to about 85%) was found to depend upon contact time between the soil and the leaching solution and the characteristics of the conditioning solution. The saturation of the soil with a NaNO(3) solution before the treatment, favoured the flushing process reducing the time of percolation, but resulted in a lower metal extraction during the following percolation of EDTA. The indigenous iron was competitive with copper to form EDTA complexes only when it was present in the organic and oxides-hydroxides fractions. Artificial iron addition to the soil resulted in an increase of both the exchangeable iron and the iron bonded to the organic fraction of the soil, thus increasing the overall amount of iron available to extraction. In both batch and continuous tests, the mechanism of copper extraction was found to involve the former dissolution of metal salts, that lead to an initial high concentration of both copper and selected competitive cations (essentially Ca(2+)), and the following EDTA exchange reaction between calcium and copper complexes. The initial metal salts dissolution was found to be pH-dependant.
Ng, Ding-Quan; Liu, Shu-Wei; Lin, Yi-Pin
2018-09-15
In this study, a sampling campaign with a total of nine sampling events investigating lead in drinking water was conducted at 7 sampling locations in an old building with lead pipes in service in part of the building on the National Taiwan University campus. This study aims to assess the effectiveness of four different sampling methods, namely first draw sampling, sequential sampling, random daytime sampling and flush sampling, in lead contamination detection. In 3 out of the 7 sampling locations without lead pipe, lead could not be detected (<1.1 μg/L) in most samples regardless of the sampling methods. On the other hand, in the 4 sampling locations where lead pipes still existed, total lead concentrations >10 μg/L were consistently observed in 3 locations using any of the four sampling methods while the remaining location was identified to be contaminated using sequential sampling. High lead levels were consistently measured by the four sampling methods in the 3 locations in which particulate lead was either predominant or comparable to soluble lead. Compared to first draw and random daytime samplings, although flush sampling had a high tendency to reduce total lead in samples in lead-contaminated sites, the extent of lead reduction was location-dependent and not dependent on flush durations between 5 and 10 min. Overall, first draw sampling and random daytime sampling were reliable and effective in determining lead contamination in this study. Flush sampling could reveal the contamination if the extent is severe but tends to underestimate lead exposure risk. Copyright © 2018 Elsevier B.V. All rights reserved.
Kubal, Chandrashekhar; Mangus, Richard; Fridell, Jonathan; Saxena, Romil; Rush, Natalia; Wingler, Matthew; Ekser, Burcin; Tector, Joseph
2016-08-01
Donation after circulatory death (DCD) donor pool remains underutilized for liver transplantation (LT). We describe optimizing "modifiable risk factors," such as cold ischemia time (CIT) recipient warm ischemia time (WIT) and the use of thrombolytic flush at the time of procurement to minimize ischemic cholangiopathy (IC). From July 2011 (era II), to improve outcomes after DCD LT, measures were taken to minimize CIT, operative time and recipient WIT along with the use of tissue plasminogen activator (tPA) flush during DCD procurements. Thirty consecutive DCD LTs were performed prospectively in era II. Outcomes were compared with 61 historic controls (era I). Reperfusion biopsies were evaluated for the presence of necrosis and biliary epithelial damage. Median CIT (4.9 [3.5-5.9] vs 6.4 [4.3-12]; P < 0.001), hepatectomy time (70 [42-120] vs 81 [58-207]; P = 0.02), and recipient WIT (16 [13-31] vs 24[15-40]; P < 0.001) were significantly shorter in era II. All patients in era II received tPA flushed liver grafts. None of the patients in era II developed IC (0% vs 18%; P = 0.013). There were fewer biliary complications in era II, and there was no increased risk of bleeding associated with the use of tPA. One-year graft survival was slightly better in era II (n = 24 patients with 1 year follow-up) (88% vs 80%; P = 0.14). Optimizing peritransplant conditions, such as shortening ischemic times with the use of thrombolytic donor flush, may prevent IC after DCD LT. With this approach, the DCD donor pool may be expanded.
A comparison of eutrophication impacts in two harbours in Hong Kong with different hydrodynamics
NASA Astrophysics Data System (ADS)
Xu, J.; Yin, K.; Liu, H.; Lee, J. H. W.; Anderson, D. M.; Ho, A. Y. T.; Harrison, P. J.
2010-11-01
Eutrophication impacts may vary spatially and temporally due to different physical processes. Using a 22-year time series data set (1986-2007), a comparison was made of eutrophication impacts between the two harbours with very different hydrodynamic conditions. Victoria Harbour (Victoria) receives sewage effluent and therefore nutrients are abundant. In the highly-flushed Victoria, the highest monthly average Chl a (13 μg L -1) occurred during the period of strongest stratification in summer as a result of rainfall, runoff and the input of the nutrient-rich Pearl River estuarine waters, but the high flushing rate restricted nutrient utilization and further accumulation of algal biomass. In other seasons, vertical mixing induced light limitation and horizontal dilution led to low Chl a (< 2 μg L -1) and no spring bloom. Few hypoxic events (DO < 2 mg L -1) occurred due to re-aeration and limited accumulation at depth due to flushing and vertical mixing. Therefore, Victoria is resilient to nutrient enrichment. In contrast, in the weakly-flushed Tolo Harbour (Tolo), year long stratification, long residence times and weak tidal currents favored algal growth, resulting in a spring diatom bloom and high Chl a (10-30 μg L -1) all year and frequent hypoxic events in summer. Hence, Tolo is susceptible to nutrient enrichment and responded to nutrient reduction after sewage diversion in 1997. Sewage diversion from Tolo resulted in a 32-38% decrease in algal biomass in Tolo, but not in Victoria. There has been a significant increase (11-22%) in bottom DO in both harbours. Our findings demonstrate that an understanding of the role of physical processes is critical in order to predict the effectiveness of sewage management strategies in reducing eutrophication impacts.
Dynamics of Biofilm Regrowth in Drinking Water Distribution Systems
Husband, S.; Loza, V.; Boxall, J.
2016-01-01
ABSTRACT The majority of biomass within water distribution systems is in the form of attached biofilm. This is known to be central to drinking water quality degradation following treatment, yet little understanding of the dynamics of these highly heterogeneous communities exists. This paper presents original information on such dynamics, with findings demonstrating patterns of material accumulation, seasonality, and influential factors. Rigorous flushing operations repeated over a 1-year period on an operational chlorinated system in the United Kingdom are presented here. Intensive monitoring and sampling were undertaken, including time-series turbidity and detailed microbial analysis using 16S rRNA Illumina MiSeq sequencing. The results show that bacterial dynamics were influenced by differences in the supplied water and by the material remaining attached to the pipe wall following flushing. Turbidity, metals, and phosphate were the main factors correlated with the distribution of bacteria in the samples. Coupled with the lack of inhibition of biofilm development due to residual chlorine, this suggests that limiting inorganic nutrients, rather than organic carbon, might be a viable component in treatment strategies to manage biofilms. The research also showed that repeat flushing exerted beneficial selective pressure, giving another reason for flushing being a viable advantageous biofilm management option. This work advances our understanding of microbiological processes in drinking water distribution systems and helps inform strategies to optimize asset performance. IMPORTANCE This research provides novel information regarding the dynamics of biofilm formation in real drinking water distribution systems made of different materials. This new knowledge on microbiological process in water supply systems can be used to optimize the performance of the distribution network and to guarantee safe and good-quality drinking water to consumers. PMID:27208119
Utility of Operative Glaucoma Tube Shunt Viscoelastic Bolus Flush.
Groth, Sylvia L; Greider, Kelsi L; Sponsel, William Eric
2015-01-01
To assess the utility of viscoelastic injection to induce bleb expansion and decrease intraocular pressure (IOP) in eyes with encapsulated glaucoma tube shunt blebs. Case series. Forty-three glaucomatous eyes, including 13 eyes with congenital, 13 uveitic, 5 neovascular, 5 open angle, 4 narrow angle and 3 traumatic glaucomas. Methods, interventions or testing: All patients underwent viscoelastic flush procedure. A pre-bent 27 or 30-gauge cannula was passed through a 25-gauge paracentesis, advanced over the iris across the anterior chamber, and insinuated into the tube shunt lumen. Once the cannula was firmly lodged in position, 0.45 to 0.85 ml of viscoelastic was injected to hyperinflate the bleb. Paired t-tests were performed comparing preoperative IOP and number of medications used preoperatively vs levels measured at 1, 6, 12, 18 and 24 months. Intraocular pressure was reduced from a mean preoperative level of 26.0 ± 1.2 (sem) mm Hg to 15.8 ± 1.0 at 1 month, remaining stable thereafter at each 6-month interval with 15.1 ± 1.1 mm Hg at 24 months (p < 0.0001). Medication use did not vary significantly from baseline. Pressure remained < 21 mm Hg after 2 years in 85% of eyes cannulated within 1 year of primary tube shunt implantation (n = 23), and in 62% of eyes cannulated more than 1 year after tube shunt placement (n = 20). Tube shunt expansion with bolus viscoelastic flush successfully restored encapsulated bleb function, providing a substantial (~10 mm Hg) IOP decrease into the mid-normal pressure range. This persisted in the majority of treated eyes for the entire study period. How to cite this article: Groth SL, Greider KL, Sponsel WE. Utility of Operative Glaucoma Tube Shunt Viscoelastic Bolus Flush. J Curr Glaucoma Pract 2015;9(3):73-76.
Primary secretory otitis media in Cavalier King Charles spaniels.
Cole, Lynette K
2012-11-01
Primary secretory otitis media (PSOM) is a disease that has been described in the Cavalier King Charles spaniel (CKCS). A large, bulging pars flaccida identified on otoscopic examination confirms the diagnosis. However, in many CKCS with PSOM the pars flaccida is flat, and radiographic imaging is needed to confirm the diagnosis. Current treatment for PSOM includes performing a myringotomy into the caudal-ventral quadrant of the pars tensa with subsequent flushing of the mucus out of the bulla using a video otoscope. Repeat myringotomies and flushing of the middle ear are necessary to keep the middle ear free of mucus. Copyright © 2012 Elsevier Inc. All rights reserved.
[Herbal medicine in womens' life cycle].
Ben-Arye, Eran; Oren, Amnon; Ben-Arie, Alon
2006-10-01
Women use herbs and other traditional and complementary modalities to treat various ailments throughout their life circle. This article reviewed 19 randomized controlled trials, which studied efficacy and safety of various herbs in the treatment of premenstrual syndrome (PMS), nausea and vomiting in the first trimester of pregnancy and menopausal hot flushes. Preliminary data support the efficacy of Chaste tree fruit (Vitex agnus) in the treatment of PMS, Ginger (Zingiber officinale) in the treatment of hyperemesis gravidarum and (Cimicifuga racemosa) in the treatment of menopausal hot flushes. Additional and more rigorous studies are warranted in order to support the efficacy and safety of these herbal remedies.
Bigwood, J; Beug, M W
1982-05-01
Analysis of Psilocybe cubensis (Earle) Singer grown in controlled culture showed that the level of psilocin was generally zero in the first (or sometimes even the second) fruiting of the mushroom from a given culture and that the level reached a maximum by the fourth flush. The level of psilocybin, which was nearly always at least twice the level of psilocin, showed no upward or downward trend as fruiting progressed, but was variable over a factor of four. Samples obtained from outside sources had psilocybin levels varying by over a factor of ten from one collection to the next.
Stable Algorithm For Estimating Airdata From Flush Surface Pressure Measurements
NASA Technical Reports Server (NTRS)
Whitmore, Stephen, A. (Inventor); Cobleigh, Brent R. (Inventor); Haering, Edward A., Jr. (Inventor)
2001-01-01
An airdata estimation and evaluation system and method, including a stable algorithm for estimating airdata from nonintrusive surface pressure measurements. The airdata estimation and evaluation system is preferably implemented in a flush airdata sensing (FADS) system. The system and method of the present invention take a flow model equation and transform it into a triples formulation equation. The triples formulation equation eliminates the pressure related states from the flow model equation by strategically taking the differences of three surface pressures, known as triples. This triples formulation equation is then used to accurately estimate and compute vital airdata from nonintrusive surface pressure measurements.
Mini-BRU/BIPS foil bearing development
NASA Technical Reports Server (NTRS)
Dobler, F. X.; Miller, L. J.
1978-01-01
The analysis revealed the failure agent to be a combination of poor teflon coating adhesion, a decrease in bearing sway space and, possibly, lack of flushing flow through the bearing. A change in Teflon coating vendors provided substantially improved coating quality and surface finish. The sway space was increased and the cooling bleed flow was adjusted to flush the bearing. These changes were included in a test conducted in the WHL from 6 April to 22 May 1978 which resulted in the completion of 1006.9 hours of operation at temperature and load. Post-test inspection revealed the bearings to be in excellent condition and capable of completing a much longer test.
Woodman, N D; Rees-White, T C; Beaven, R P; Stringfellow, A M; Barker, J A
2017-08-01
This paper describes a programme of research investigating horizontal fluid flow and solute transport through saturated municipal solid waste (MSW) landfill. The purpose is to inform engineering strategies for future contaminant flushing. Solute transport between injection/abstraction well pairs (doublets) is investigated using three tracers over five separate tests at well separations between 5m and 20m. Two inorganic tracers (lithium and bromide) were used, plus the fluorescent dye tracer, rhodamine-WT. There was no evidence for persistent preferential horizons or pathways at the inter-well scale. The time for tracer movement to the abstraction wells varied with well spacing as predicted for a homogeneous isotropic continuum. The time for tracer movement to remote observation wells was also as expected. Mobile porosity was estimated as ~0.02 (~4% of total porosity). Good fits to the tracer breakthrough data were achieved using a dual-porosity model, with immobile regions characterised by block diffusion timescales in the range of about one to ten years. This implies that diffusional exchanges are likely to be very significant for engineering of whole-site contaminant flushing and possibly rate-limiting. Copyright © 2017. Published by Elsevier B.V.
Mayer, Lori; Fink, Mary Kay; Sammarco, Carrie; Laing, Lisa
2018-04-01
Delayed-release dimethyl fumarate is an oral disease-modifying therapy that has demonstrated significant efficacy in adults with relapsing-remitting multiple sclerosis. Incidences of flushing and gastrointestinal adverse events are common in the first month after delayed-release dimethyl fumarate initiation. Our objective was to propose mitigation strategies for adverse events related to initiation of delayed-release dimethyl fumarate in the treatment of patients with multiple sclerosis. Studies of individually developed mitigation strategies and chart reviews were evaluated. Those results, as well as mitigation protocols developed at multiple sclerosis care centers, are summarized. Key steps to optimize the effectiveness of delayed-release dimethyl fumarate treatment include education prior to and at the time of delayed-release dimethyl fumarate initiation, initiation dose protocol gradually increasing to maintenance dose, dietary suggestions for co-administration with food, gastrointestinal symptom management with over-the-counter medications, flushing symptom management with aspirin, and temporary dose reduction. Using the available evidence from clinical trials and evaluations of post-marketing studies, these strategies to manage gastrointestinal and flushing symptoms can be effective and helpful to the patient when initiating delayed-release dimethyl fumarate.
Performance of WVSS-II hygrometers on the FAAM Research Aircraft
NASA Astrophysics Data System (ADS)
Vance, A. K.; Abel, S. J.; Cotton, R. J.; Woolley, A. M.
2014-08-01
We compare the performance of five hygrometers fitted to the Facility for Airborne Atmospheric Measurement's (FAAM) BAe 146-301 research aircraft using data from approximately one hundred flights executed over the course of two years under a wide range of conditions. Bulk comparison of cloud free data show good agreement between chilled mirror hygrometers and a WVSS-II fed from a modified Rosemount inlet but that a WVSS-II fed from the standard flush inlet appears to over read compared to the other instruments, except at higher humidities. Statistical assessment of hygrometer performance in cloudy conditions is problematic due to the variable nature of clouds, so a number of case studies are used instead to investigate the performance of the hygrometers in sub optimal conditions. It is found that the flush inlet is not susceptible to either liquid or solid water but that the Rosemount inlet has a significant susceptibility to liquid water; it is not susceptible to ice. In all conditions the WVSS-II respond much more rapidly than the chilled mirror devices, with the flush inlet-fed WVSS-II being more rapid than that connected to the Rosemount.
Performance of WVSS-II hygrometers on the FAAM research aircraft
NASA Astrophysics Data System (ADS)
Vance, A. K.; Abel, S. J.; Cotton, R. J.; Woolley, A. M.
2015-03-01
We compare the performance of five hygrometers fitted to the Facility for Airborne Atmospheric Measurement's (FAAM) BAe 146-301 research aircraft using data from approximately 100 flights executed over the course of 2 years under a wide range of conditions. Bulk comparison of cloud free data show good agreement between chilled mirror hygrometers and a WVSS-II fed from a modified Rosemount inlet, but that a WVSS-II fed from the standard flush inlet appears to over-read compared to the other instruments, except at higher humidities. Statistical assessment of hygrometer performance in cloudy conditions is problematic due to the variable nature of clouds, so a number of case studies are used instead to investigate the performance of the hygrometers in sub-optimal conditions. It is found that the flush inlet is not susceptible to either liquid or solid water but that the Rosemount inlet has a significant susceptibility to liquid water and may also be susceptible to ice. In all conditions the WVSS-II responds much more rapidly than the chilled mirror devices, with the flush inlet-fed WVSS-II being more rapid than that connected to the Rosemount.
Earthquakes drive large-scale submarine canyon development and sediment supply to deep-ocean basins.
Mountjoy, Joshu J; Howarth, Jamie D; Orpin, Alan R; Barnes, Philip M; Bowden, David A; Rowden, Ashley A; Schimel, Alexandre C G; Holden, Caroline; Horgan, Huw J; Nodder, Scott D; Patton, Jason R; Lamarche, Geoffroy; Gerstenberger, Matthew; Micallef, Aaron; Pallentin, Arne; Kane, Tim
2018-03-01
Although the global flux of sediment and carbon from land to the coastal ocean is well known, the volume of material that reaches the deep ocean-the ultimate sink-and the mechanisms by which it is transferred are poorly documented. Using a globally unique data set of repeat seafloor measurements and samples, we show that the moment magnitude ( M w ) 7.8 November 2016 Kaikōura earthquake (New Zealand) triggered widespread landslides in a submarine canyon, causing a powerful "canyon flushing" event and turbidity current that traveled >680 km along one of the world's longest deep-sea channels. These observations provide the first quantification of seafloor landscape change and large-scale sediment transport associated with an earthquake-triggered full canyon flushing event. The calculated interevent time of ~140 years indicates a canyon incision rate of 40 mm year -1 , substantially higher than that of most terrestrial rivers, while synchronously transferring large volumes of sediment [850 metric megatons (Mt)] and organic carbon (7 Mt) to the deep ocean. These observations demonstrate that earthquake-triggered canyon flushing is a primary driver of submarine canyon development and material transfer from active continental margins to the deep ocean.
Zhang, Xiangru; Minear, Roger A
2006-03-01
High-molecular weight (MW) halogenated disinfection byproducts (DBPs) may cause adverse health effects. In this work several issues related to the better separation and characterization of the high MW halogenated DBPs (MW>500Da) were studied. Ultra-filtration (UF) coupled with a nominal 500-Da membrane was employed to flush out low MW DBPs and inorganic ions. Two procedures, intermittent UF and continuous UF, were used and compared. The results demonstrate that haloacetic acids, chloride and sodium ions could be effectively flushed out, and most of phosphate ions could be flushed out for a given dilution number or sufficient Milli-Q water. The size exclusion chromatograms indicate that haloacetic acids and trihalomethanes were not bound to Suwannee River fulvic acid (SRFA); 2,4,6-trichlorophenol might form some binding with SRFA, but it appeared to be very weak and readily broken up when passing along the size exclusion column. The octanol-water partition coefficients of low MW DBPs and the properties of humic substances seem to play key roles in determining the formation of possible bindings between low MW DBPs and humic substances.
Wind noise measured at the ground surface.
Yu, Jiao; Raspet, Richard; Webster, Jeremy; Abbott, Johnpaul
2011-02-01
Measurements of the wind noise measured at the ground surface outdoors are analyzed using the mirror flow model of anisotropic turbulence by Kraichnan [J. Acoust. Soc. Am. 28(3), 378-390 (1956)]. Predictions of the resulting behavior of the turbulence spectrum with height are developed, as well as predictions of the turbulence-shear interaction pressure at the surface for different wind velocity profiles and microphone mounting geometries are developed. The theoretical results of the behavior of the velocity spectra with height are compared to measurements to demonstrate the applicability of the mirror flow model to outdoor turbulence. The use of a logarithmic wind velocity profile for analysis is tested using meteorological models for wind velocity profiles under different stability conditions. Next, calculations of the turbulence-shear interaction pressure are compared to flush microphone measurements at the surface and microphone measurements with a foam covering flush with the surface. The measurements underneath the thin layers of foam agree closely with the predictions, indicating that the turbulence-shear interaction pressure is the dominant source of wind noise at the surface. The flush microphones measurements are intermittently larger than the predictions which may indicate other contributions not accounted for by the turbulence-shear interaction pressure.
Howard-Thompson, Amanda; Dutton, Anna; Hoover, Robert; Goodfred, Jennifer
2014-12-01
A brand of fish oil capsules contains omega-3 fatty acids obtained from several fish sources. Although the manufacturer calls for caution in patients with fish hypersensitivity, insufficient data is available to make a definitive recommendation regarding its use in this population. A patient with documented seafood allergy presented to the emergency department 4 days after the initiation of prescription brand name fish oil capsules complaining of chest tightness, shortness of breath, tingling of upper extremities, flushing, and pruritus that was minimally relieved by excessive nonprescription diphenhydramine administration. During subsequent follow-up, the patient reported that all symptoms had resolved within 5 days of discontinuing the medication and 3 days of disposing of her pillbox and all medications that had come in contact with the fish oil capsules. Due to the patient's allergic history, timing of onset/offset of the reaction, laboratory evidence, and the use of the Naranjo probability scale, prescription fish oil capsules were deemed the probable cause of this patient's pruritus and flushing of the face and trunk. Practitioners and patients should always ensure they have an updated list of allergies within the patient's medical record that includes medications as well as foods and food additives.
NASA Technical Reports Server (NTRS)
Whitmore, Stephen A.; Moes, Timothy R.
1994-01-01
Presented is a feasibility and error analysis for a hypersonic flush airdata system on a hypersonic flight experiment (HYFLITE). HYFLITE heating loads make intrusive airdata measurement impractical. Although this analysis is specifically for the HYFLITE vehicle and trajectory, the problems analyzed are generally applicable to hypersonic vehicles. A layout of the flush-port matrix is shown. Surface pressures are related airdata parameters using a simple aerodynamic model. The model is linearized using small perturbations and inverted using nonlinear least-squares. Effects of various error sources on the overall uncertainty are evaluated using an error simulation. Error sources modeled include boundarylayer/viscous interactions, pneumatic lag, thermal transpiration in the sensor pressure tubing, misalignment in the matrix layout, thermal warping of the vehicle nose, sampling resolution, and transducer error. Using simulated pressure data for input to the estimation algorithm, effects caused by various error sources are analyzed by comparing estimator outputs with the original trajectory. To obtain ensemble averages the simulation is run repeatedly and output statistics are compiled. Output errors resulting from the various error sources are presented as a function of Mach number. Final uncertainties with all modeled error sources included are presented as a function of Mach number.
Albert, A; Altabre, C; Baró, F; Buendía, E; Cabero, A; Cancelo, M J; Castelo-Branco, C; Chantre, P; Duran, M; Haya, J; Imbert, P; Julía, D; Lanchares, J L; Llaneza, P; Manubens, M; Miñano, A; Quereda, F; Ribes, C; Vázquez, F
2002-03-01
A multicentric, open, prospective, observational and no-randomized clinical trial was carried out in Spain with 190 postmenopausal women receiving a soy preparation rich in isoflavones (PHYTO SOYA, capsules containing 17.5 mg isoflavones). The main object of the present study was to investigate its efficacy in alleviating the symptomatology derived from the lack of estrogen, mainly hot flushes, but also other symptoms such as sleep disorder, anxiety, depression, vaginal dryness, loss of libido and bone pain. Each patient received 35 mg isoflavones per day in two doses. During the four months' treatment, a statistically significant decrease in the number of hot flushes with PHYTO SOYA was experienced by 80.82% women; only 5,48% patients did not improve with the treatment. The average reduction was 47.8%, which is equivalent to 4 hot flushes. All the other studied parameters also showed a statistically significant decrease. No severe side-effects were reported and tolerance was excellent. Treatment with PHYTO SOYA resulted in a significant improvement of the symptomatology that accompanies the lack of estrogen during menopause.
Mycoplasmateceae species are not found in Fallopian tubes of women with tubo-peritoneal infertility.
Costoya, Alberto; Morales, Francisco; Borda, Paula; Vargas, Renato; Fuhrer, Juan; Salgado, Nicole; Cárdenas, Hugo; Velasquez, Luis
2012-01-01
The role of mycoplasmas on the development and sequelae of pelvic inflammatory disease remains controversial. The objective of the present study is to correlate directly the presence of Mycoplasmateceae through polimerase chain reaction (PCR) determinations in cervix and Fallopian tubes of infertile patients with tubo-peritoneal factor diagnosed through laparoscopy. Thirty patients with tubo-peritoneal infertility and 30 normal fertile patients were included in the study; cervical samples and tubal flushings were obtained during laparoscopy. PCR determinations for the detection of genetic material of Mycoplasma genitalium, Mycoplasma hominis, Ureaplasma urealiticum, Neisseria gonorrhoeae, Chlamydia trachomatis, Trichomonas vaginalis in cervix and tubal flushings were performed. No Mycoplasmataceae species as "only" microorganisms were found in tubal flushings of tubo-peritoneal infertility patients, whereas three (10%) fertile patients with normal tubes were positive for mycoplasma presence. This difference was not significant (p = 0.237). Among the 30 patients suffering from tubal infertility diagnosed through laparoscopy, Mycoplasmatecae species were not detected in the Fallopian tubes by PCR determinations, while in normal tubes from fertile patients these and other microorganisms could be found without distorting tubal anatomy. Mycoplasmateceae species were not detected in Fallopian tubes of women with tubo-peritoneal infertility.
Ghata, Narugopal; Aldredge, Ralph C.; Bec, Julien; Marcu, Laura
2015-01-01
SUMMARY Optical techniques including fluorescence lifetime spectroscopy have demonstrated potential as a tool for study and diagnosis of arterial vessel pathologies. However, their application in the intravascular diagnostic procedures has been hampered by the presence of blood hemoglobin that affects the light delivery to and the collection from the vessel wall. We report a computational fluid dynamics model that allows for the optimization of blood flushing parameters in a manner that minimizes the amount of saline needed to clear the optical field of view and reduces any adverse effects caused by the external saline jet. A 3D turbulence (k−ω) model was employed for Eulerian–Eulerian two-phase flow to simulate the flow inside and around a side-viewing fiber-optic catheter. Current analysis demonstrates the effects of various parameters including infusion and blood flow rates, vessel diameters, and pulsatile nature of blood flow on the flow structure around the catheter tip. The results from this study can be utilized in determining the optimal flushing rate for given vessel diameter, blood flow rate, and maximum wall shear stress that the vessel wall can sustain and subsequently in optimizing the design parameters of optical-based intravascular catheters. PMID:24953876
NASA Astrophysics Data System (ADS)
Woodman, N. D.; Rees-White, T. C.; Beaven, R. P.; Stringfellow, A. M.; Barker, J. A.
2017-08-01
This paper describes a programme of research investigating horizontal fluid flow and solute transport through saturated municipal solid waste (MSW) landfill. The purpose is to inform engineering strategies for future contaminant flushing. Solute transport between injection/abstraction well pairs (doublets) is investigated using three tracers over five separate tests at well separations between 5 m and 20 m. Two inorganic tracers (lithium and bromide) were used, plus the fluorescent dye tracer, rhodamine-WT. There was no evidence for persistent preferential horizons or pathways at the inter-well scale. The time for tracer movement to the abstraction wells varied with well spacing as predicted for a homogeneous isotropic continuum. The time for tracer movement to remote observation wells was also as expected. Mobile porosity was estimated as 0.02 ( 4% of total porosity). Good fits to the tracer breakthrough data were achieved using a dual-porosity model, with immobile regions characterised by block diffusion timescales in the range of about one to ten years. This implies that diffusional exchanges are likely to be very significant for engineering of whole-site contaminant flushing and possibly rate-limiting.
Dalton, C F; Laird, S M; Estdale, S E; Saravelos, H G; Li, T C
1998-11-01
The concentrations of endometrial proteins PP14 and CA-125 were measured in uterine flushings taken on days LH+10 and LH+12 (10 and 12 days after luteinizing hormone surge) of the menstrual cycle from 15 normal, fertile women and 49 women who suffered recurrent miscarriage. The concentration of PP14 was significantly lower in the flushings from the recurrent miscarriage patients than in those from fertile controls on both day LH+10 (median: 1300, range: 3-10 300 ng/ml versus median: 13 933, range: 2174-40 404 ng/ml; P < 0.01) and LH+12 (median: 1560, range: 820-12 100 ng/ml versus median: 14 047, range 1402-62 108 ng/ml; P < 0.05). Similarly concentrations of CA-125 were significantly lower in flushings from recurrent miscarriage women compared to controls on both day LH + 10 (median: 1555, range: 47-6710 U/ml versus median: 6385.5, range 2884-27 731 U/ml, P < 0.01) and LH+12 (median: 2892, range: 956-9974 U/ml versus median: 7127.5, range: 1591-21 343 U/ml; P < 0.05). In contrast there was no significant difference in the concentration of PP14 in plasma samples taken on the same days as the flushings from recurrent miscarriage patients and fertile controls. The concentrations of PP14 in uterine flushings obtained on day LH + 10 or LH + 12 from recurrent miscarriage women during a pre-pregnancy investigative cycle were significantly lower (P < 0.05) in patients who went on to miscarry (median: 1000, range: 9-2900 ng/ml) than those who went on to have a live birth (median: 1440, range: 4-12 100 ng/ml) during a subsequent pregnancy. In contrast there was no significant difference in uterine CA-125 or plasma PP14 concentrations between these two groups of recurrent miscarriage patients. The results suggest that measurements of uterine PP14 and CA-125 may be useful in the assessment of endometrial development in recurrent miscarriage patients and suggest the importance of PP14 in preparing the endometrium for embryo implantation. In addition pre-pregnancy uterine PP14 measurements may be useful in predicting subsequent pregnancy outcome.
Acupuncture for menopausal vasomotor symptoms: study protocol for a randomised controlled trial
2014-01-01
Background Hot flushes and night sweats (vasomotor symptoms) are common menopausal symptoms, often causing distress, sleep deprivation and reduced quality of life. Although hormone replacement therapy is an effective treatment, there are concerns about serious adverse events. Non-hormonal pharmacological therapies are less effective and can also cause adverse effects. Complementary therapies, including acupuncture, are commonly used for menopausal vasomotor symptoms. While the evidence for the effectiveness of acupuncture in treating vasomotor symptoms is inconclusive, acupuncture has a low risk of adverse effects, and two small studies suggest it may be more effective than non-insertive sham acupuncture. Our objective is to assess the efficacy of needle acupuncture in improving hot flush severity and frequency in menopausal women. Our current study design is informed by methods tested in a pilot study. Methods/design This is a stratified, parallel, randomised sham-controlled trial with equal allocation of participants to two trial groups. We are recruiting 360 menopausal women experiencing a minimum average of seven moderate hot flushes a day over a seven-day period and who meet diagnostic criteria for the Traditional Chinese Medicine diagnosis of Kidney Yin deficiency. Exclusion criteria include breast cancer, surgical menopause, and current hormone replacement therapy use. Eligible women are randomised to receive either true needle acupuncture or sham acupuncture with non-insertive (blunt) needles for ten treatments over eight weeks. Participants are blinded to treatment allocation. Interventions are provided by Chinese medicine acupuncturists who have received specific training on trial procedures. The primary outcome measure is hot flush score, assessed using the validated Hot Flush Diary. Secondary outcome measures include health-related quality of life, anxiety and depression symptoms, credibility of the sham treatment, expectancy and beliefs about acupuncture, and adverse events. Participants will be analysed in the groups in which they were randomised using an intention-to-treat analysis strategy. Discussion Results from this trial will significantly add to the current body of evidence on the role of acupuncture for vasomotor symptoms. If found to be effective and safe, acupuncture will be a valuable additional treatment option for women who experience menopausal vasomotor symptoms. Trial registration Australian New Zealand Clinical Trials Registry ACTRN12611000393954 11/02/2009. PMID:24925094
Goodwin, C.R.
1996-01-01
A two-dimensional circulation and constituent- transport model, SIMSYS2D, was used to simulate tidal-flow, circulation, and flushing characteristics in Charlotte Harbor. The model was calibrated and verified against field observations of stage,discharge, and velocity. Standard errors averaged about 3 percent of the range in stage at the tide stations and between 3 and 10 percent of the range in discharge measured in the inlets for the calibration period. Following calibration and verification, the model was applied to three different conditions. The first condition represented the existing physical configuration and typical freshwater inflow. The second condition represented reduced fresh water inflow, and the third represented an alteration of Sanibel Causeway. All three conditions were evaluated through Lagrangian particle tracks and simulated dye injections. Residual circulation patterns were similar for typical and reduced freshwater inflow, but reduced freshwater inflow increased the residence time in the upper harbor by a factor of two or more. Removal of Sanibel Causeway did not significantly affect residual flows in upper and lower Charlotte Harbor, Matlacha Pass, Gasparilla Sound, or the Gulf of Mexico. Analysis of Lagrangian particle tracks indicated changes in residence times in San Carlos Bay as a result of removing Sanibel Causeway, but the changes were not consistent for all particles. The residence time of 8 particles in San Carlos Bay decreased with removal of the causeway, 1 was unchanged, and the residence time of 3 particles increased. Simulated flushing characteristics of the estuarine system were affected more by reduced freshwater inflow than for typical freshwater inflow. After 30 days of simulation of reduced freshwater inflow, 42 percent of the dye injected into the upper harbor remained in the upper harbor, compared to 28 percent for typical freshwater inflow. The upper harbor has a relatively long flushing time because it is not directly connected to the gulf and some of the dye that exits to the lower harbor returns to the upper harbor by way of a landward residual flow in the deep center channel. The upper harbor is also sensitive to reduced freshwater inflow because it is the subarea closest to freshwater inflow from the Peace and Myakka Rivers. Removal of Sanibel Causeway had a slight effect on the flushing of Pine Island Sound and San Carlos Bay, but had no significant effect in upper and lower Charlotte Harbor.
Bitensky, Mark W.; Yoshida, Tatsuro
1997-01-01
Method using oxygen removal for extending the useful shelf-life of refrigerated red blood cells. A cost-effective, 4.degree. C. storage procedure that preserves red cell quality and prolongs post-transfusion in vivo survival is described. Preservation of adenosine triphosphate levels and reduction in hemolysis and in membrane vesicle production of red blood cells stored at 4.degree. C. for prolonged periods of time is achieved by removing oxygen therefrom at the time of storage; in particular, by flushing with an inert gas. Adenosine triphosphate levels of the stored red blood cells are boosted in some samples by addition of ammonium phosphate.
Bitensky, M.W.; Yoshida, Tatsuro
1997-04-29
A method is disclosed using oxygen removal for extending the useful shelf-life of refrigerated red blood cells. A cost-effective, 4 C storage procedure that preserves red cell quality and prolongs post-transfusion in vivo survival is described. Preservation of adenosine triphosphate levels and reduction in hemolysis and in membrane vesicle production of red blood cells stored at 4 C for prolonged periods of time is achieved by removing oxygen from the red blood cells at the time of storage; in particular, by flushing with an inert gas. Adenosine triphosphate levels of the stored red blood cells are boosted in some samples by addition of ammonium phosphate. 4 figs.
Evaluation of RO modules for the SSP ETC/LSS.
NASA Technical Reports Server (NTRS)
Jasionowski, W. J.; Bambenek, R. A.
1973-01-01
During the past eight years the NASA Manned Spacecraft Center has supported the development of an Integrated Water and Waste Management System for use in the Space Station Prototype (SSP) Environmental Thermal Control/Life-Support System (ETC/LSS). This system includes the reverse osmosis (RO) process for recycling wash water and the compression distillation process for recovering useable water from urine, urinal flush water, humidity condensate, commode flush water and the wash water concentrated by RO. This paper summarizes the experimental work performed during the past four years to select the best commercially available RO module for this system and to also define which surfactants and germicides are most compatible with the selected module.
Flushing of a polluted lagoon in Canc'un, using a SIBEO wave-driven seawater pump
NASA Astrophysics Data System (ADS)
Czitrom, Steven; Carbajal, Noel
2006-11-01
The coastal lagoon which adorns the seaside resort at Canc'un, Mexico, is heavily polluted as a result of decades of intense tourist activity development and overwhelmed inadequate planning. The natural flushing time of the lagoon, estimated at 2 to 4 years, is insufficient to cope with the waste that is being dumped and a thick layer of organic matter has accumulated on the lagoon bed. Appropriate legal and sewage treatment measures are imperative to curb further dumping and thus attack the root cause of the problem. This aside, however, the existing situation requires additional technical solutions to restore the ecosystem to a less altered state. A wave and tide driven seawater pump, invented and developed at the National University of Mexico, has been proposed to flush the lagoon with an average 0.2 m^3/s of clean and oxygen rich seawater from the neighboring ocean. This flow would reduce the residence time of the lagoon to around 6 months, promoting long term recovery of the ecosystem. The effect and distribution of the pumped water is being studied using a wind and tide driven 3D numerical model of the lagoon hydrodynamics. Some results from this study are presented here.
Kim, L H; Jeong, S M; Ko, S O
2007-01-01
Recently the Ministry of Environment in Korea has developed the total maximum daily load program in accordance with the target pollutant and its concentration goal on four major large rivers. Since the program is largely related to regional development, nonpoint source control is both important and topical. Of the various nonpoint sources, highways are stormwater intensive land uses since they are impervious and have high pollutant mass emissions from vehicular activity. The event mean concentration (EMC) is useful in estimating the loadings to receiving water bodies. However, the EMC does not provide information on the time varying changes in pollutant concentration or mass emissions, which are often important for best management practice development, or understanding shock loads. Therefore, in this study a new concept, the dynamic EMC determination method, will be introduced to clearly verify the relationship between EMC and the first flush effect. Three monitoring sites in Daejeon metropolitan city areas were equipped with an automatic rainfall gauge and a flow meter for accumulating the data such as rainfall and runoff flow. The dynamic EMC method was applied to more than 17 events, and the improved first flush criteria were determined on the ranges of storm duration and accumulated rainfall.
Quality of stormwater runoff from paved surfaces of two production sites.
Gnecco, I; Berretta, C; Lanza, L G; La Barbera, P
2006-01-01
In order to investigate stormwater pollutant loads associated with different anthropic activities and the related pollutant build-up and wash-off processes, two pilot sites have been equipped in the Liguria Region (Italy) for monitoring first flush water quality in a gas station and an auto dismantler facility. TSS, COD, HCtot and heavy metals in dissolved form (Zn, Pb, Cu, Ni, Cd, Cr) have been analyzed during the monitoring campaign (started in February 2004). Stormwater flow and quality data collected in both production sites confirm that EMC values are significantly higher than those observed in an urban site. In the auto dismantler site, the EMC values for TSS, COD and HC largely exceed the standard values (EC 91/271). Contrary to urban surface runoff, scarce correlation between TSS and COD concentrations is observed in runoff from both production sites. The occurrence and nature of the pollutant load connected to first flush flows is discussed by inspection of the M(V)-curves that are provided for all monitored water quality parameters. Significant first flush phenomenon is evidenced for TSS and HC, while such clear behavior doesn't emerge for heavy metals. Hydrologic and climatic characteristics (ADWP, rainfall intensity/depth) appear to scarcely affect the build-up and wash-off processes.
NASA Technical Reports Server (NTRS)
Moes, Timothy R.; Whitmore, Stephen A.; Jordan, Frank L., Jr.
1993-01-01
A nonintrusive airdata-sensing system was calibrated in flight and wind-tunnel experiments to an angle of attack of 70 deg and to angles of sideslip of +/- 15 deg. Flight-calibration data have also been obtained to Mach 1.2. The sensor, known as the flush airdata sensor, was installed on the nosecap of an F-18 aircraft for flight tests and on a full-scale F-18 forebody for wind-tunnel tests. Flight tests occurred at the NASA Dryden Flight Research Facility, Edwards, California, using the F-18 High Alpha Research Vehicle. Wind-tunnel tests were conducted in the 30- by 60-ft wind tunnel at the NASA LaRC, Hampton, Virginia. The sensor consisted of 23 flush-mounted pressure ports arranged in concentric circles and located within 1.75 in. of the tip of the nosecap. An overdetermined mathematical model was used to relate the pressure measurements to the local airdata quantities. The mathematical model was based on potential flow over a sphere and was empirically adjusted based on flight and wind-tunnel data. For quasi-steady maneuvering, the mathematical model worked well throughout the subsonic, transonic, and low supersonic flight regimes. The model also worked well throughout the angle-of-attack and sideslip regions studied.
NASA Technical Reports Server (NTRS)
Moes, Timothy R.; Whitmore, Stephen A.; Jordan, Frank L., Jr.
1993-01-01
A nonintrusive airdata-sensing system was calibrated in flight and wind-tunnel experiments to an angle of attack of 70 deg and to angles of sideslip of +/- 15 deg. Flight-calibration data have also been obtained to Mach 1.2. The sensor, known as the flush airdata sensor, was installed on the nosecap of an F-18 aircraft for flight tests and on a full-scale F-18 forebody for wind-tunnel tests. Flight tests occurred at the NASA Dryden Flight Research Facility, Edwards, California, using the F-18 High Alpha Research Vehicle. Wind-tunnel tests were conducted in the 30- by 60-ft wind tunnel at the NASA LaRC, Hampton, Virginia. The sensor consisted of 23 flush-mounted pressure ports arranged in concentric circles and located within 1.75 in. of the tip of the nosecap. An overdetermined mathematical model was used to relate the pressure measurements to the local airdata quantities. The mathematical model was based on potential flow over a sphere and was empirically adjusted based on flight and wind-tunnel data. For quasi-steady maneuvering, the mathematical model worked well throughout the subsonic, transonic, and low supersonic flight regimes. The model also worked well throughout the angles-of-attack and -sideslip regions studied.
Effect of wave-current interaction on wind-driven circulation in narrow, shallow embayments
Signell, Richard P.; Beardsley, Robert C.; Graber, H. C.; Capotondi, A.
1990-01-01
The effect of wind waves on the steady wind-driven circulation in a narrow, shallow bay is investigated with a two-dimensional (y, z) circulation model and the Grant and Madsen [1979] bottom-boundary layer model, which includes wave-current interaction. A constant wind stress is applied in the along-channel x direction to a channel with a constant cross-sectional profile h(y). The wind-induced flushing of shallow bays is shown to be sensitive to both the shape of the cross section and the effects of surface waves. The flushing increases with increasing , where h′ is the standard deviation of cross-channel depth and is the mean depth. This is consistent with the findings of Hearn et al. [1987]. The flushing decreases, however, with the inclusion of surface wave effects which act to increase the bottom drag felt by the currents. Increasing effective bottom friction reduces the strength of the circulation, while the along-bay surface slope, bottom stress and the structure of current profiles remain nearly unchanged. An implication of the circulation dependence on wave-current interaction is that low-frequency oscillatory winds may drive a mean circulation when the wave field changes with wind direction.x
[First flush effects of storm events of Baoxiang River in Lake Dianchi Watershed].
Guo, Huai-Cheng; Xiang, Nan; Zhou, Feng; Wang, Yong-Hua; Li, Fa-Rong; Zhu, Xiang; Mao, Guo-Zhu; Yu, Shu-Xia; Li, Na; Sheng, Hu; Yang, Yong-Hui; He, Cheng-Jie; Wang, Cui-Yu
2013-04-01
To understand riverine process of non-point source effectively, first flush effects of storm events were investigated at Baoxiang River of Lake Dianchi Watershed. Three sampling stations were selected along Baoxiang River for observing the flow rate and pollutant concentrations of the first three storm events from June 2009 to August 2009. Net discharged volume, net discharged loading, and net event mean concentration (EMC(n)) were proposed with their calculation methods. According to the analysis of three storm events at three stations, the following results colcd be extracted: (1) the larger the percent of impervious land and population density were, the higher EMC(n) of TSS, TN, TP, permanganate index and their cumulative curves [M(V)] were along the river; (2) TSS, TP loadings as well as their M (V) were positively correlated to the storm intensity, while TN and permanganate index loadings were consistent with the total rainfall of each storm event, where the percent of NO3(-) -N in total nitrogen decreased gradually when the number of storm events increased; (3) compared to tradition EMC, EMC(n) was proven to be a better indicator to accurately uncover and magnify the differences in first flush effects of storm events among different stations or storm events.
Hand-pumps as reservoirs for microbial contamination of well water
Ferguson, Andrew S.; Mailloux, Brian J.; Ahmed, Kazi M.; van Geen, Alexander; McKay, Larry D.; Culligan, Patricia J.
2018-01-01
The retention and release of total coliforms and Escherichia coli was investigated in hand-pumps removed from tubewells tapping a faecally contaminated aquifer in Matlab, Bangladesh, and from a new hand-pump deliberately spiked with E. coli. All hand-pumps were connected to reservoirs of sterile water and flushed. Faecal coliforms were observed in the discharge from all three of the previously used hand-pumps, at concentrations comparable to levels measured in discharge when they were attached to the tubewells. During daily flushing of one of the previously used hand-pumps, the concentration of total coliforms in the discharge remained relatively constant (≈103 MPN/100 mL). Concentrations of E. coli in the pump discharge declined over time, but E. coli was still detectable up to 29 days after the start of flushing. In the deliberately spiked hand-pump, E. coli was observed in the discharge over 125 days (t50 = 8 days) and found to attach preferentially to elastomeric materials within the hand-pump. Attempts to disinfect both the village and new hand-pumps using shock chlorination were shown to be unsuccessful. These results demonstrate that hand-pumps can act as persistent reservoirs for microbial indicator bacteria. This could potentially influence drinking water quality and bias testing of water quality. PMID:22048430
Investigation of vinegar production using a novel shaken repeated batch culture system.
Schlepütz, Tino; Büchs, Jochen
2013-01-01
Nowadays, bioprocesses are developed or optimized on small scale. Also, vinegar industry is motivated to reinvestigate the established repeated batch fermentation process. As yet, there is no small-scale culture system for optimizing fermentation conditions for repeated batch bioprocesses. Thus, the aim of this study is to propose a new shaken culture system for parallel repeated batch vinegar fermentation. A new operation mode - the flushing repeated batch - was developed. Parallel repeated batch vinegar production could be established in shaken overflow vessels in a completely automated operation with only one pump per vessel. This flushing repeated batch was first theoretically investigated and then empirically tested. The ethanol concentration was online monitored during repeated batch fermentation by semiconductor gas sensors. It was shown that the switch from one ethanol substrate quality to different ethanol substrate qualities resulted in prolonged lag phases and durations of the first batches. In the subsequent batches the length of the fermentations decreased considerably. This decrease in the respective lag phases indicates an adaptation of the acetic acid bacteria mixed culture to the specific ethanol substrate quality. Consequently, flushing repeated batch fermentations on small scale are valuable for screening fermentation conditions and, thereby, improving industrial-scale bioprocesses such as vinegar production in terms of process robustness, stability, and productivity. Copyright © 2013 American Institute of Chemical Engineers.
Zheng, Wei; Lü, Fan; Bolyard, Stephanie C; Shao, Liming; Reinhart, Debra R; He, Pinjing
2015-02-01
To understand the applicability of the termination indicators for landfill municipal solid waste (MSW) with low initial lignin content, four different accelerated landfill stabilization techniques were applied to anaerobic landfilled waste, including anaerobic flushing with water, anaerobic flushing with Fenton-treated leachate, and aerobic flushing with Fenton-treated and UV/H2O2-treated leachate. Termination indicators, including total organic carbon (TOC), ammonia-N (NH4(+)-N), the ratio of UV absorbance at 254 nm to TOC concentration (SUVA254), fluorescence spectra of leachate, methane production, oxygen consumption, lignocellulose content, and humus-like content were evaluated. Results suggest that oxygen consumption related indicators used as a termination indicator for low-lignin-content MSW were more sensitive than methane consumption related indicators. Aeration increased humic acid (HA) and (HA+FA)/HyI content by 2.9 and 1.7 times compared to the anaerobically stabilized low-lignin-content MSW. On the other hand, both the fulvic acid (FA) and hydrophilic (HyI) fractions remained constant regardless of stabilization technique. The target value developed for low-lignin-content MSW was quite different than developed countries mainly due to low residual biodegradable organic carbon content in stabilized low-lignin-content MSW. Copyright © 2014 Elsevier Ltd. All rights reserved.
Analysis and Results from a Flush Airdata Sensing System in Close Proximity to Firing Rocket Nozzles
NASA Technical Reports Server (NTRS)
Ali, Aliyah N.; Borrer, Jerry L.
2013-01-01
This paper presents information regarding the nosecap Flush Airdata Sensing (FADS) system on Orion’s Pad Abort 1 (PA-1) vehicle. The purpose of the nosecap FADS system was to test whether or not useful data could be obtained from a FADS system if it was placed in close proximity to firing rocket nozzles like the Attitude Control Motor (ACM) nozzles on the PA-1 Launch Abort System. The nosecap FADS system used pressure measurements from a series of pressure ports which were arranged in a cruciform pattern and flush with the surface of the vehicle to estimate values of angle of attack, angle of sideslip, Mach number, impact pressure, and freestream static pressure. This paper will present the algorithms employed by the FADS system along with the development of the calibration datasets and a comparison of the final results to the Best Estimated Trajectory (BET) data for PA-1. Also presented in this paper is a Computational Fluid Dynamics (CFD) study to explore the impact of the ACM on the nosecap FADS system. The comparison of the nosecap FADS system results to the BET and the CFD study showed that more investigation is needed to quantify the impact of the firing rocket motors on the FADS system.
Alfa, M J; Nemes, R
2004-09-01
We undertook a simulated-use study using quantitative methods to evaluate the cleaning efficacy of ported and non-ported accessory devices used in minimally invasive surgery. We chose laparoscopic scissors and forceps to represent worst-case devices which were inoculated with artificial test soil containing 10(6) cfu/mL Enterococcus faecalis and Geobacillus stearothermophilus and allowed to dry for 1 h. Cleaning was performed manually, as well as by the automated SI-Auto Narrow lumen cleaner. Manual cleaning left two- to 50-fold more soil residuals (protein, haemoglobin and carbohydrate) inside the lumen of non-ported versus ported laparoscopic accessory devices. The SI-Auto Narrow lumen cleaner was more efficient than manual cleaning and achieved >99% reduction in soil parameters in both non-ported (using retro-flushing) and ported laparoscopic devices. Only the automated cleaning of ported devices achieved 10(3)-10(4)-fold reduction in bacterial numbers. Sonication alone (no flushing of inner channel) did not effectively remove soil or organisms from the inner channel. Our findings indicate that non-ported accessory devices cannot be as reliably cleaned as ported devices regardless of the cleaning method used. If non-ported accessory devices are reprocessed, they should be cleaned using retro-flushing in an automated narrow lumen cleaner.
NASA Technical Reports Server (NTRS)
Scallion, William I.
1999-01-01
A 0.0196-scale model of the HL-20 lifting-body, one of several configurations proposed for future crewed spacecraft, was tested in the Langley 31-Inch Mach 10 Tunnel. The purpose of the tests was to determine the effectiveness of fin-mounted elevons, a lower surface flush-mounted body flap, and a flush-mounted yaw controller at hypersonic speeds. The nominal angle-of-attack range, representative of hypersonic entry, was 2 deg to 41 deg, the sideslip angles were 0 deg, 2 deg, and -2 deg, and the test Reynolds number was 1.06 x 10 E6 based on model reference length. The aerodynamic, longitudinal, and lateral control effectiveness along with surface oil flow visualizations are presented and discussed. The configuration was longitudinally and laterally stable at the nominal center of gravity. The primary longitudinal control, the fin-mounted elevons, could not trim the model to the desired entry angle of attack of 30 deg. The lower surface body flaps were effective for roll control and the associated adverse yawing moment was eliminated by skewing the body flap hinge lines. A yaw controller, flush-mounted on the lower surface, was also effective, and the associated small rolling moment was favorable.
A Case Report of Acute Vitamin A Intoxication due to Ocean Perch Liver Ingestion.
Homma, Yosuke; Otani, Norio; Ishimatsu, Shinichi
2015-07-01
Chronic vitamin A intoxication is well known; however, there are few reports of acute vitamin A intoxication due to the ingestion of food rich in vitamin A, particularly in adults. We report a case of a 27-year-old man presenting with chief complaints of flushing, headache, nausea, and joint pain. He had consumed 800 g of grilled ocean perch liver the day before and had experienced numbness shortly after. Although physical examination revealed only facial flushing, we suspected acute vitamin A intoxication due to his diet history. On day 2 after ingestion, his serum retinol levels were elevated at 1577 ng/mL, which confirmed vitamin A intoxication. He returned for follow-up on day 4 after ingestion, by which time his presenting symptoms had improved, but he had developed desquamation of his facial skin. WHY SHOULD AN EMERGENCY PHYSICIAN BE AWARE OF THIS?: Emergency physicians should consider acute vitamin A intoxication in the differential diagnosis of patients with headache, flushing, desquamation, nausea, and vomiting of unknown etiology. Complete diet histories and checking vitamin A levels are essential for diagnosis. This report highlights the diagnostic difficulties associated with vitamin A intoxication and the importance of an accurate diet history. Copyright © 2015 Elsevier Inc. All rights reserved.
Methods of preventing vinorelbine-induced phlebitis: an experimental study in rabbits.
Kohno, Emiko; Murase, Saori; Nishikata, Mayumi; Okamura, Noboru; Matzno, Sumio; Kuwahara, Takashi; Matsuyama, Kenji
2008-07-22
In order to identify methods for preventing phlebitis caused by intravenous administration of vinorelbine (VNR), we established a procedure for estimating the severity of phlebitis in an animal model. Four different factors (administration rate, dilution, flushing, and infusion of fat emulsion) were evaluated for alleviation of phlebitis caused by VNR infusion. VNR was diluted with normal saline to prepare test solutions with concentrations of 0.6 mg/mL or 0.3 mg/mL for infusion into the auricular veins of rabbits. Two days after VNR infusion, the veins were subjected to histopathological examination. VNR did not cause obvious loss of venous endothelial cells, the most sensitive and common feature of phlebitis, but VNR infusion led to inflammatory cell infiltration, edema, and epidermal degeneration. Tissue damage was significantly decreased by shortening the administration time and by diluting the VNR solution for infusion from 0.6 mg/mL to 0.3 mg/mL. However, there was no effect of flushing with normal saline after VNR infusion, while treatment with fat emulsion before and after VNR infusion only had a minimal effect. Rapid infusion and dilution are effective methods of reducing phlebitis caused by the infusion of VNR, but the efficacy of flushing with normal saline or infusion of fat emulsion was not confirmed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
McCray, J.E.; Boving, T.B.; Brusseau, M.L.
2000-12-31
Reagents that enhance the aqueous solubility of nonaqueous phase organic liquid (NAPL) contaminants are under investigation for use in enhanced subsurface remediation technologies. Cyclodextrin, a glucose-based molecule, is such a reagent. In this paper, laboratory experiments and numerical model simulations are used to evaluate and understand the potential remediation performance of cyclodextrin. Physical properties of cyclodextrin solutions such as density, viscosity, and NAPL-aqueous interfacial tension are measured. Their analysis indicates that no serious obstacles exist related to fluid properties that would prevent the use of cyclodextrin solutions for subsurface NAPL remediation. Cyclodextrin-enhanced solubilization for a large suite of typical groundmore » water contaminants is measured in the laboratory, and the results are related to the physiochemical properties of the organic compounds. The most-hydrophobic contaminants experience a larger relative solubility enhancement than the less-hydrophobic contaminants but have lower aqueous-phase apparent solubilities. Numerical model simulations of enhanced-solubilization flushing of NAPL-contaminated soil demonstrate that the more-hydrophilic compounds exhibit the greatest mass-removal relates due to their greater apparent solubilities, and thus are initially more effectively removed from soil by enhanced-solubilization-flushing reagents. However, the relatively more hydrophobic contaminants exhibit a greater improvement in contaminant mass-removal (compared with water flushing) than that exhibited for the relatively hydrophilic contaminants.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Boving, T.B.; Wang, X.; Brusseau, M.L.
1999-03-01
The development of improved methods for remediation of contaminated aquifers has emerged as a significant environmental priority. One technology that appears to have considerable promise involves the use of solubilization agents such as surfactants and cosolvents for enhancing the removal of residual phase immiscible liquids. The authors examined the use of cyclodextrin, a glucose-based molecule, for solubilizing and removing residual-phase immiscible liquid from porous media. Batch experiments were conducted to measure the degree of trichloroethene (TCE) and tetrachloroethene (PCE) solubilization induced by hydroxypropyl-{beta}-cyclodextrin (HPCD) and methyl-{beta}-cyclodextrin (MCD). These studies revealed that the solubilities of TCE and PCE were enhanced bymore » up to 9.5 and 36.0 times, respectively. Column experiments were conducted to compare water and cyclodextrin-enhanced flushing of Borden sand containing residual saturations of TCE and PCE. The results indicate that solubilization and mass removal were enhanced substantially with the use of cyclodextrins. The effluent concentrations during the steady-state phase of the HPCD and MCD flushing experiments were close to the apparent solubilities measured with the batch experiments, indicating equilibrium concentrations were maintained during the initial phase of cyclodextrin flushing. Mobilization was observed for only the TCE-MCD and PCE-5%MCD experiments.« less
Alfa, Michelle J; Singh, Harminder; Nugent, Zoann; Duerksen, Donald; Schultz, Gale; Reidy, Carol; DeGagne, Patricia; Olson, Nancy
2017-01-01
Simulated-use buildup biofilm (BBF) model was used to assess various extraction fluids and friction methods to determine the optimal sample collection method for polytetrafluorethylene channels. In addition, simulated-use testing was performed for the channel and lever cavity of duodenoscopes. BBF was formed in polytetrafluorethylene channels using Enterococcus faecalis, Escherichia coli , and Pseudomonas aeruginosa . Sterile reverse osmosis (RO) water, and phosphate-buffered saline with and without Tween80 as well as two neutralizing broths (Letheen and Dey-Engley) were each assessed with and without friction. Neutralizer was added immediately after sample collection and samples concentrated using centrifugation. Simulated-use testing was done using TJF-Q180V and JF-140F Olympus duodenoscopes. Despite variability in the bacterial CFU in the BBF model, none of the extraction fluids tested were significantly better than RO. Borescope examination showed far less residual material when friction was part of the extraction protocol. The RO for flush-brush-flush (FBF) extraction provided significantly better recovery of E. coli ( p = 0.02) from duodenoscope lever cavities compared to the CDC flush method. We recommend RO with friction for FBF extraction of the channel and lever cavity of duodenoscopes. Neutralizer and sample concentration optimize recovery of viable bacteria on culture.
Blokker, E J Mirjam; van de Ven, Bianca M; de Jongh, Cindy M; Slaats, P G G Nellie
2013-05-01
Coal tar and bitumen have been historically used to coat the insides of cast iron drinking water mains. Polycyclic aromatic hydrocarbons (PAHs) may leach from these coatings into the drinking water and form a potential health risk for humans. We estimated the potential human cancer risk from PAHs in coated cast iron water mains. In a Dutch nationwide study, we collected drinking water samples at 120 locations over a period of 17 days under various operational conditions, such as undisturbed operation, during flushing of pipes, and after a mains repair, and analyzed these samples for PAHs. We then estimated the health risk associated with an exposure scenario over a lifetime. During flushing, PAH levels frequently exceeded drinking water quality standards; after flushing, these levels dropped rapidly. After the repair of cast iron water mains, PAH levels exceeded the drinking water standards for up to 40 days in some locations. The estimated margin of exposure for PAH exposure through drinking water was > 10,000 for all 120 measurement locations, which suggests that PAH exposure through drinking water is of low concern for consumer health. However, factors that differ among water systems, such as the use of chlorination for disinfection, may influence PAH levels in other locations.
Souza, Marcelo C de; Bueno, Paula C P; Morellato, Leonor P C; Habermann, Gustavo
2015-01-01
The cerrado's flora comprises aluminum-(Al) accumulating and non-accumulating plants, which coexist on acidic and Al-rich soils with low fertility. Despite their existence, the ecological importance or biological strategies of these functional groups have been little explored. We evaluated the leaf flushing patterns of both groups throughout a year; leaf concentrations of N, P, K, Ca, Mg, S, Al, total flavonoids and polyphenols; as well as the specific leaf area (SLA) on young and mature leaves within and between the groups. In Al-accumulating plants, leaf flushed throughout the year, mainly in May and September; for non-accumulating plants, leaf flushing peaked at the dry-wet seasons transition. However, these behaviors could not be associated with strategies for building up concentrations of defense compounds in leaves of any functional groups. Al-accumulating plants showed low leaf nutrient concentrations, while non-accumulating plants accumulated more macronutrients and produced leaves with high SLA since the juvenile leaf phase. This demonstrates that the increase in SLA is slower in Al-accumulating plants that are likely to achieve SLA values comparable to the rest of the plant community only in the wet season, when sunlight capture is important for the growth of new branches.
van de Ven, Bianca M.; de Jongh, Cindy M.
2013-01-01
Background: Coal tar and bitumen have been historically used to coat the insides of cast iron drinking water mains. Polycyclic aromatic hydrocarbons (PAHs) may leach from these coatings into the drinking water and form a potential health risk for humans. Objective: We estimated the potential human cancer risk from PAHs in coated cast iron water mains. Method: In a Dutch nationwide study, we collected drinking water samples at 120 locations over a period of 17 days under various operational conditions, such as undisturbed operation, during flushing of pipes, and after a mains repair, and analyzed these samples for PAHs. We then estimated the health risk associated with an exposure scenario over a lifetime. Results: During flushing, PAH levels frequently exceeded drinking water quality standards; after flushing, these levels dropped rapidly. After the repair of cast iron water mains, PAH levels exceeded the drinking water standards for up to 40 days in some locations. Conclusions: The estimated margin of exposure for PAH exposure through drinking water was > 10,000 for all 120 measurement locations, which suggests that PAH exposure through drinking water is of low concern for consumer health. However, factors that differ among water systems, such as the use of chlorination for disinfection, may influence PAH levels in other locations. PMID:23425894
The flushing and exchange of the South China Sea derived from salt and mass conservation
NASA Astrophysics Data System (ADS)
Liu, Yang; Bye, John A. T.; You, Yuzhu; Bao, Xianwen; Wu, Dexing
2010-07-01
In this paper, we use two kinds of hydrographic data, historical cruise data, Array for Real-time Geostrophic Oceanography (Argo) float data, and atmospheric data to study the water exchange between the South China Sea (SCS) and the Pacific Ocean through the Luzon Strait. The annual mean distributions of temperature and salinity at five different levels in the SCS and the adjacent Pacific Ocean are presented, which indicate the occurrence of active water exchange through the Luzon Strait. The flushing and exchange of the SCS are then determined by the application of salt and mass conservation in a multi-layered thermohaline system, using an estimate of the net rainfall obtained from reanalysis data. The results show that the annual mean flushing time is 44±8 months with an inflow rate of 11±2 Sv (1 Sv=10 6 m 3 s -1), part of which recirculates at a deeper level through the Luzon Strait, the remainder (6±2 Sv) forming the SCS throughflow. The diffusive influx of salt is also estimated and accounts for about 10% of the total influx, and hence advection dominates over diffusion in the water exchange through the Luzon Strait. The seasonal cycle of exchange shows a maximum in autumn and winter of about twice the annual mean rate.
Rossignol, Patrick; Dorval, Marc; Fay, Renaud; Ros, Joan Fort; Loughraieb, Nathalie; Moureau, Frédérique; Laville, Maurice
2013-06-01
Anticoagulation for chronic dialysis patients with contraindications to heparin administration is challenging. Current guidelines state that in patients with increased bleeding risks, strategies that can induce systemic anticoagulation should be avoided. Heparin-free dialysis using intermittent saline flushes is widely adopted as the method of choice for patients at risk of bleeding, although on-line blood predilution may also be used. A new dialyzer, Evodial (Gambro, Lund, Sweden), is grafted with unfractionated heparin during the manufacturing process and may allow safe and efficient heparin-free hemodialysis sessions. In the present trial, Evodial was compared to standard care with either saline flushes or blood predilution. The HepZero study is the first international (seven countries), multicenter (10 centers), randomized, controlled, open-label, non-inferiority (and if applicable subsequently, superiority) trial with two parallel groups, comprising 252 end-stage renal disease patients treated by maintenance hemodialysis for at least 3 months and requiring heparin-free dialysis treatments. Patients will be treated during a maximum of three heparin-free dialysis treatments with either saline flushes or blood predilution (control group), or Evodial. The first heparin-free dialysis treatment will be considered successful when there is: no complete occlusion of air traps or dialyzer rendering dialysis impossible; no additional saline flushes to prevent clotting; no change of dialyzer or blood lines because of clotting; and no premature termination (early rinse-back) because of clotting.The primary objectives of the study are to determine the effectiveness of the Evodial dialyzer, compared with standard care in terms of successful treatments during the first heparin-free dialysis. If the non-inferiority of Evodial is demonstrated then the superiority of Evodial over standard care will be tested. The HepZero study results may have major clinical implications for patient care. ClinicalTrials.gov NCT01318486.
NASA Astrophysics Data System (ADS)
Sun, Q.; Meyer, W. S.; Koerber, G.; Marschner, P.
2015-06-01
Semi-arid woodlands, which are characterised by patchy vegetation interspersed with bare, open areas, are frequently exposed to wild fire. During summer, long dry periods are occasionally interrupted by rainfall events. It is well-known that rewetting of dry soil induces a flush of respiration. However, the magnitude of the flush may differ between vegetation patches and open areas because of different organic matter content which could be further modulated by wild fire. Soils were collected from under trees, under shrubs or in open areas in unburnt and burnt sandy Mallee woodland, where part of the woodland experienced a wild fire which destroyed or damaged most of the aboveground plant parts four months before sampling. In an incubation experiment, the soils were exposed to two moisture treatments: constantly moist (CM) and drying and rewetting (DRW). In CM, soils were incubated at 80% of maximum water holding capacity for 19 days; In DRW, soils were dried for four days, kept dry for another five days, then rewet to 80% WHC and maintained at this water content until day 19. Soil respiration decreased during drying and was very low in the dry period; rewetting induced a respiration flush. Compared to soil under shrubs and in open areas, cumulative respiration per g soil in CM and DRW was greater under trees, but lower when expressed per g TOC. Organic matter content, available P, and microbial biomass C, but not available N were greater under trees than in open areas. Wild fire decreased the flush of respiration per g TOC in the open areas and under shrubs, and reduced TOC and MBC concentrations only under trees, but had little effect on available N and P concentrations. We conclude that of the impact wild fire and DRW events on nutrient cycling differ among vegetation patches of a native semiarid woodland which is related to organic matter amount and availability.
Buzzelli, C.; Holland, Austin F.; Sanger, D.M.; Conrads, P.C.
2007-01-01
Many coastal ecosystems are undergoing anthropogenic stress from large increases in population and urbanization. In many regions changes in freshwater and material inputs to the coastal zone are altering the biogeochemical and biological capacities of ecosystems. Despite increased watershed inputs, large tidal volumes and flushing indicative of macrotidal estuaries can modulate the fate of introduced materials masking some of the symptoms of eutrophication. The Land Use Coastal Ecosystem Study (LU-CES) examined linkages between land use and environmental properties of Malind and Okatee Creeks in South Carolina from 2001 to 2004. The objectives of this particular study were to assess the hydrography of the two macrotidal creek ecosystems, explore differences in dissolved oxygen (DO), and develop a better understanding of the variations in primary and benthic secondary production in southeastern creek ecosystems. Depth, pH, salinity, and DO were reduced and more variable in Malind Creek than in Okatee Creek, although both creeks had strong semidiurnal frequencies in salinity time signatures. While time series analyses of DO saturation in Malind Creek revealed a dominant semidiurnal pattern, Okatee Creek had a distinctly diel DO pattern. The strongly semidiurnal fluctuations in DO and reduced flushing time indicated that biological processes were not fast enough to influence DO in Malind Creek. The Okatee Creek system had a much greater storage volume, a wider marsh, and a dominant 25-h DO frequency. These attributes contributed to an estimated 8-10 times more phytoplankton-based carbon in Okatee Creek and twice the annual benthic production. As expected from their proximity to the upland, low surface area, and high organic content, both ecosystems were net heterotrophic. This fundamental understanding of tidal creek hydrography is being used to help define linkages among differential watershed land uses, flushing characteristics, and levels of biological production in coastal ecosystems of the southeastern United States. ?? 2007 Estuarine Research Federation.
Zingue, Stéphane; Nde, Chantal Beatrice Magne; Michel, Thomas; Ndinteh, Derek Tantoh; Tchatchou, Jules; Adamou, Moïse; Fernandez, Xavier; Fohouo, Fernand-Nestor Tchuenguem; Clyne, Colin; Njamen, Dieudonné
2017-01-21
Since the biological properties of propolis depend to the plants that can be found in a specific region, propolis from unexplored regions attracts the attention of scientists. Ethanolic extract of Cameroonian propolis (EEP) is used to treat various ailments including gynecological problems and amenorrhea. Since there were no scientific data to support the above claims, the present study was therefore undertaken to assess estrogenic properties of Cameroonian propolis. To achieve our goal, the ability of EEP to induce MCF-7 cells proliferation in E-screen assay as well as to activate estrogen receptors α (ERα) and β (ERβ) in cell-based reporter gene assays using human embryonic kidney cells (HEK293T) transfected with ERs was tested. Further, a 3-day uterotrophic assay was performed and the ability of EEP to alleviate hot flushes in ovariectomized adult rats was evaluated. In vitro, EEP showed an antiestrogenic activity in both HEK293T ER-α and ER-β cells. In vivo, EEP induced a significant increase in a bell shape dose response manner of the uterine wet weight, the total protein levels in the uterus, the uterine and vaginal epithelium height and acini border cells of mammary gland with the presence of abundant eosinophil secretions. Moreover, EEP induced a significant decrease in the total number, average duration as well as frequency of hot flushes after 3 days of treatment in rat (equivalent to a month in woman). The dose of 150 mg/kg exhibited the most potent estrogenic effects among all the tested doses. The UPLC-HRMS analysis showed the presence of caffeic acid derivatives and trirtepernoids in EEP, which are well known endowed with estrogenic properties. These results suggest that Ethanolic extract of Cameroonian propolis has estrogen-like effects in vivo and may alleviate some menopausal problems such as vaginal dryness and hot flushes. Ethanol-extracted Cameroobian propolis exhibited in vitro and in vivo estrogen-like effects. This extract may contain promising phytoestrogens.
You, Tao; Jiang, Jianliang; Chen, Jianchang; Xu, Weiting; Xiang, Li; Jiao, Yang
2017-01-01
Heparin has typically been used as a flushing or infusion solution for vascular lines in daily practice. However, several clinical trials have yielded controversial results about the benefits of heparin in maintaining peripheral venous catheters. The present meta-analysis was conducted to evaluate the efficacy of heparin on the patency profiles and complications in peripheral intravenous catheters. PubMed, Embase and Cochrane Central Register of Controlled Trials were searched up to February 2016 for randomized controlled trials comparing heparin with placebo in maintaining peripheral intravenous catheters. Additional studies were retrieved from the reference lists of identified articles. In total 32 eligible studies were included, from which the pooled standard mean difference (SMD), relative risk (RR) and corresponding 95% confidence interval (CI) were calculated. The use of heparin as a continuous infusion significantly prolonged the duration of patency (SMD, 0.90; 95% CI, 0.48–1.32; P<0.001), reduced rates of infusion failure (RR, 0.83; 95% CI, 0.76–0.92; P<0.001) and occlusion (RR, 0.82; 95% CI, 0.69–0.98; P<0.05) in a peripheral intravenous catheter. However, there were no significant changes in the duration of patency and infusion failure when heparin was used intermittently as a flushing solution, although a significantly decreased risk of occlusion was observed in this setting (RR, 0.80; 95% CI, 0.66–0.98; P<0.05). Furthermore, the risk of phlebitis was significantly decreased by both continuous infusion (RR, 0.66; 95% CI, 0.58–0.75; P<0.01) and intermittent flushing (RR, 0.70; 95% CI, 0.56–0.86; P<0.01) of heparin in peripheral venous catheters. In conclusion, the use of heparin as continuous infusion in peripheral intravenous catheters improved the duration of patency, reduced infusion failure and phlebitis, whereas heparin as intermittent flushing showed more benefits in ameliorating phlebitis rather than in patency profiles. PMID:28810636
Effect of pronase as mucolytic agent on imaging quality of magnifying endoscopy.
Kim, Gwang Ha; Cho, Yu Kyung; Cha, Jae Myung; Lee, Sun-Young; Chung, Il-Kwun
2015-02-28
To investigate the efficacy of premedication with pronase, a proteolytic enzyme, in improving image quality during magnifying endoscopy. The study was of a blinded, randomized, prospective design. Patients were assigned to groups administered oral premedication of either pronase and simethicone (Group A) or simethicone alone (Group B). First, the gastric mucosal visibility grade (1-4) was determined during conventional endoscopy, and then a magnifying endoscopic examination was conducted. The quality of images obtained by magnifying endoscopy at the stomach and the esophagus was scored from 1 to 3, with a lower score indicating better visibility. The endoscopist used water flushes as needed to obtain satisfactory magnifying endoscopic views. The main study outcomes were the visibility scores during magnifying endoscopy and the number of water flushes. A total of 144 patients were enrolled, and data from 143 patients (M:F=90:53, mean age 57.5 years) were analyzed. The visibility score was significantly higher in the stomach following premedication with pronase (73% with a score of 1 in Group A vs 49% in Group B, P<0.05), but there was no difference in the esophagus visibility scores (67% with a score of 1 in Group A vs 58% in Group B). Fewer water flushes [mean 0.7±0.9 times (range: 0-3 times) in Group A vs 1.9±1.5 times (range: 0-6 times) in Group B, P<0.05] in the pronase premedication group did not affect the endoscopic procedure times [mean 766 s (range: 647-866 s) for Group A vs 760 s (range: 678-854 s) for Group B, P=0.88]. The total gastric mucosal visibility score was also lower in Group A (4.9±1.5 vs 8.3±1.8 in Group B, P<0.01). The addition of pronase to simethicone premedication resulted in clearer images during magnifying endoscopy and reduced the need for water flushes.
Effect of pronase as mucolytic agent on imaging quality of magnifying endoscopy
Kim, Gwang Ha; Cho, Yu Kyung; Cha, Jae Myung; Lee, Sun-Young; Chung, Il-Kwun
2015-01-01
AIM: To investigate the efficacy of premedication with pronase, a proteolytic enzyme, in improving image quality during magnifying endoscopy. METHODS: The study was of a blinded, randomized, prospective design. Patients were assigned to groups administered oral premedication of either pronase and simethicone (Group A) or simethicone alone (Group B). First, the gastric mucosal visibility grade (1-4) was determined during conventional endoscopy, and then a magnifying endoscopic examination was conducted. The quality of images obtained by magnifying endoscopy at the stomach and the esophagus was scored from 1 to 3, with a lower score indicating better visibility. The endoscopist used water flushes as needed to obtain satisfactory magnifying endoscopic views. The main study outcomes were the visibility scores during magnifying endoscopy and the number of water flushes. RESULTS: A total of 144 patients were enrolled, and data from 143 patients (M:F = 90:53, mean age 57.5 years) were analyzed. The visibility score was significantly higher in the stomach following premedication with pronase (73% with a score of 1 in Group A vs 49% in Group B, P < 0.05), but there was no difference in the esophagus visibility scores (67% with a score of 1 in Group A vs 58% in Group B). Fewer water flushes [mean 0.7 ± 0.9 times (range: 0-3 times) in Group A vs 1.9 ± 1.5 times (range: 0-6 times) in Group B, P < 0.05] in the pronase premedication group did not affect the endoscopic procedure times [mean 766 s (range: 647-866 s) for Group A vs 760 s (range: 678-854 s) for Group B, P = 0.88]. The total gastric mucosal visibility score was also lower in Group A (4.9 ± 1.5 vs 8.3 ± 1.8 in Group B, P < 0.01). CONCLUSION: The addition of pronase to simethicone premedication resulted in clearer images during magnifying endoscopy and reduced the need for water flushes. PMID:25741158
Sexual Function in Women on Estradiol or Venlafaxine for Hot Flushes: A Randomized Controlled Trial
Reed, Susan D.; Mitchell, Caroline M.; Joffe, Hadine; Cohen, Lee; Shifren, Jan L.; Newton, Katherine M.; Freeman, Ellen W.; Larson, Joseph C.; Manson, JoAnn E.; LaCroix, Andrea Z.; Guthrie, Katherine A.
2014-01-01
Objective To evaluate sexual function in midlife women taking low-dose oral estradiol or venlafaxine for hot flushes. Methods In an 8-week randomized controlled trial among women aged 40-62 years, sexual function was compared between oral estradiol 0.5 mg/day or venlafaxine 75 mg/day (both compared with placebo). Measures included composite and 6 domain scores from the Female Sexual Function Index (FSFI) and sexually related personal distress. Results Participants were aged 54.6 (standard deviation [SD] 3.8) years, 59% Caucasian, with 8.1 (SD 5.3) daily hot flushes. Median composite baseline FSFI score was 16.3 (SD 11.9, n=256) for all women and 21.7 (SD 9.3, n=198) among sexually active women. Composite mean FSFI change from baseline to week-8 was 1.4 (95% Confidence Interval [CI] -0.4, 3.2) for estradiol, 1.1 (95% CI -0.5, 2.7) for venlafaxine and -0.3 (95% CI -1.6, 1.0) for placebo. Composite FSFI and sexually-related distress change from baseline did not differ between estradiol and placebo (p= 0.38, p=0.30) or venlafaxine and placebo (p=0.79, p=0.48). Among sexually active women, FSFI domain score change from baseline differences (active compared with placebo) in desire was 0.3 (95% CI 0.0, 0.6) for estradiol; -0.6 (95% CI -1.2, 0.0) in orgasm for venlafaxine, and 0.9 (95% CI 0.2, 1.6) in penetration pain for venlafaxine. No women reported adverse events related to sexual dysfunction. Conclusions Overall sexual function among nondepressed midlife women experiencing hot flushes did not change over 8-weeks with low-dose oral estradiol or venlafaxine (compared with placebo), although subtle increase in desire (estradiol), and decreases in orgasm and pain (venlafaxine) may exist. PMID:25004335
Kendrick, Daniel E; Allemang, Matthew T; Gosling, Andre F; Nagavalli, Anil; Kim, Ann H; Nishino, Setsu; Parikh, Sahil A; Bezerra, Hiram G; Kashyap, Vikram S
2016-10-01
To examine the hypothesis that alternative flush media could be used for lower extremity optical coherence tomography (OCT) imaging in long lesions that would normally require excessive use of contrast. The OPTical Imaging Measurement of Intravascular Solution Efficacy (OPTIMISE) trial was a single-center, prospective study (ClinicalTrials.gov identifier NCT01743872) that enrolled 23 patients (mean age 68±11 years; 14 men) undergoing endovascular intervention involving the superficial femoral artery. Four flush media (heparinized saline, dextran, carbon dioxide, and contrast) were used in succession in random order for each image pullback. Quality was defined as ≥270° visualization of vessel wall layers from each axial image. Mean proportions (± standard deviation) of image quality for each flush medium were assessed using 1-way analysis of variance and are reported with the 95% confidence intervals (CI). Four OCT catheters failed, leaving 19 patients who completed the OCT imaging protocol; from this cohort, 51 highest quality runs were selected for analysis. Average vessel diameter was 3.99±1.01 mm. OCT imaging allowed 10- to 15-μm resolution of the lumen border, with diminishing quality as vessel diameter increased. Plaque characterization revealed fibrotic lesions. Mean proportions of image quality were dextran 87.2%±12% (95% CI 0.81 to 0.94), heparinized saline 74.3%±24.8% (95% CI 0.66 to 0.93), contrast 70.1%±30.5% (95% CI 0.52 to 0.88), and carbon dioxide 10.0%±10.4% (95% CI 0.00 to 0.26). Dextran, saline, and contrast provided better quality than carbon dioxide (p<0.001). OCT is feasible in peripheral vessels <5 mm in diameter. Dextran or saline flush media can allow lesion characterization, avoiding iodinated contrast. Carbon dioxide is inadequate for peripheral OCT imaging. Axial imaging may aid in enhancing durability of peripheral endovascular interventions. © The Author(s) 2016.
NASA Astrophysics Data System (ADS)
Wurster, Maria-Theresia; Weigelhofer, Gabriele; Pichler-Scheder, Christian; Hein, Thomas; Pöppl, Ronald
2017-04-01
Sediment connectivity describes the potential for sediment transport through catchment systems, further defining locality and characteristics of sedimentation in river channels. Dams generally decrease sediment connectivity and act as temporary sediment sinks. When dams are removed these sediments are being reworked and released downstream. During dam restoration works along a small-sized stream in the Bohemian Massif of Austria in December 2015 a dam failure occurred which led to the entrainment of several tons of fine-grained reservoir sediments further entering and depositing in the downstream channel reaches, located in the Thayatal National Park. Aiming to remove these fine sediment deposits the National Park Authority decided to initiate a flushing event in April 2016. The main aim of the present study was to investigate the effects of dam failure-induced fine sediment release and reservoir flushing on downstream bed sediment characteristics by applying geomorphological mapping (incl. volumetric surveys) and sedimentological analyses (freeze-core sampling and granulometry), further discussing the role of in-channel sediment connectivity. The obtained results have shown that immediately after the dam failure event a total of ca. 18 m3 of fine-grained sediments have accumulated as in-channel sediment bars which were primarily formed in zones of low longitudinal connectivity (e.g. in the backwater areas of woody debris jams, or at slip-off bank locations). The flushing event has been shown to have caused remobilization and downstream translocation of these deposits, further reducing their total volume by approx. 60%. The results of the granulometric analyses of the freeze-core samples have revealed fine sediment accumulation and storage in the upper parts of the channel bed, having further increased after the flushing event. Additionally, effects on chemical conditions and invertebrate community have been observed. These observations clearly indicate a significant influence of vertical connectivity conditions on in-channel fine sediment storage.
First post-fire flush in a Mediterranean temporary stream: source ascription in bed sediments
NASA Astrophysics Data System (ADS)
Estrany Bertos, Joan; García-Comendador, Julián; Fortesa, Josep; Calsamiglia, Aleix; Garcias, Francesca
2017-04-01
First flushes can be of great importance for suspended-sediment transport in fluvial systems of drylands, being temporary streams a characteristic feature of Mediterranean basins. After a wildfire, storm flows may enhance runoff delivery to channels and then increasing the first-flush effect. 137Cs and 210Pbex were used as tracers for recognizing the first post-fire flush effect in the source ascription of bed sediments temporarily stored in a Mediterranean temporary stream severely affected by a wildfire. Thirty potential sediment source samples were collected along the main stem of a catchment located in Mallorca (Spain) during a field campaign developed some weeks after the wildfire. The sample collection was designed considering the wildfire affection, and also distinguishing between soil surface and channel bank. To quantify the relative source contribution to the bed sediment temporarily stored, five sediment samples -deposited during the first storm occurred three months after the wildfire- were collected into the bed stream of the main channel. The 137Cs and 210Pbex concentrations were measured by gamma spectrometry. Then, a linear mixing model was used to establish the relative contribution of each source type to the bed sediments discerning between the most upstream and the downstream parts of the catchment. Post-fire first-flush effect was generated by a torrential event with a suspended-sediment concentration peak ca. 33,618 mg L-1, although transmission losses under a very low runoff coefficient (1%) promoted sediment deposition. Significant differences were observed in fallout radionuclide concentrations between burned surface soil and channel bank samples (p < 0.05), as well as between burned and unburned sources at the downstream part of the catchment (p < 0.01). The radioactivity concentrations in bed sediments samples were statistically similar (p > 0.05). Source ascription in bed sediments in the middle stream shows that 67% was generated in burned hillslopes, reaching 75% in the downstream part because downstream propagation of the sediment derived from the burned area. Bed sediments were mostly generated in burned hillslopes because of the fire effects on soils and sediment availability, high intensity rainfall and limited contribution of channel banks that are fixed by dry-stone walls. This hydro-sedimentary response indicates an association between driven sediment transport factors and sediment availability, generating an effective slope-to-channel sediment connectivity. Long-term sediment sources monitoring will elucidate if the most effective period of the window of disturbance at catchment scale is further extended (i.e., ≈5 years).