Security Criteria for Distributed Systems: Functional Requirements.
1995-09-01
Open Company Limited. Ziv , J. and A. Lempel . 1977. A Universal Algorithm for Sequential Data Compression . IEEE Transactions on Information Theory Vol...3, SCF-5 DCF-7. Configurable Cryptographic Algorithms (a) It shall be possible to configure the system such that the data confidentiality functions...use different cryptographic algorithms for different protocols (e.g., mail or interprocess communication data ). (b) The modes of encryption
NASA Astrophysics Data System (ADS)
Lockhart, M.; Henzlova, D.; Croft, S.; Cutler, T.; Favalli, A.; McGahee, Ch.; Parker, R.
2018-01-01
Over the past few decades, neutron multiplicity counting has played an integral role in Special Nuclear Material (SNM) characterization pertaining to nuclear safeguards. Current neutron multiplicity analysis techniques use singles, doubles, and triples count rates because a methodology to extract and dead time correct higher order count rates (i.e. quads and pents) was not fully developed. This limitation is overcome by the recent extension of a popular dead time correction method developed by Dytlewski. This extended dead time correction algorithm, named Dytlewski-Croft-Favalli(DCF), is detailed in reference Croft and Favalli (2017), which gives an extensive explanation of the theory and implications of this new development. Dead time corrected results can then be used to assay SNM by inverting a set of extended point model equations which as well have only recently been formulated. The current paper discusses and presents the experimental evaluation of practical feasibility of the DCF dead time correction algorithm to demonstrate its performance and applicability in nuclear safeguards applications. In order to test the validity and effectiveness of the dead time correction for quads and pents, 252Cf and SNM sources were measured in high efficiency neutron multiplicity counters at the Los Alamos National Laboratory (LANL) and the count rates were extracted up to the fifth order and corrected for dead time. In order to assess the DCF dead time correction, the corrected data is compared to traditional dead time correction treatment within INCC. The DCF dead time correction is found to provide adequate dead time treatment for broad range of count rates available in practical applications.
Enhancing the Selection of Backoff Interval Using Fuzzy Logic over Wireless Ad Hoc Networks
Ranganathan, Radha; Kannan, Kathiravan
2015-01-01
IEEE 802.11 is the de facto standard for medium access over wireless ad hoc network. The collision avoidance mechanism (i.e., random binary exponential backoff—BEB) of IEEE 802.11 DCF (distributed coordination function) is inefficient and unfair especially under heavy load. In the literature, many algorithms have been proposed to tune the contention window (CW) size. However, these algorithms make every node select its backoff interval between [0, CW] in a random and uniform manner. This randomness is incorporated to avoid collisions among the nodes. But this random backoff interval can change the optimal order and frequency of channel access among competing nodes which results in unfairness and increased delay. In this paper, we propose an algorithm that schedules the medium access in a fair and effective manner. This algorithm enhances IEEE 802.11 DCF with additional level of contention resolution that prioritizes the contending nodes according to its queue length and waiting time. Each node computes its unique backoff interval using fuzzy logic based on the input parameters collected from contending nodes through overhearing. We evaluate our algorithm against IEEE 802.11, GDCF (gentle distributed coordination function) protocols using ns-2.35 simulator and show that our algorithm achieves good performance. PMID:25879066
Lockhart, M.; Henzlova, D.; Croft, S.; ...
2017-09-20
Over the past few decades, neutron multiplicity counting has played an integral role in Special Nuclear Material (SNM) characterization pertaining to nuclear safeguards. Current neutron multiplicity analysis techniques use singles, doubles, and triples count rates because a methodology to extract and dead time correct higher order count rates (i.e. quads and pents) was not fully developed. This limitation is overcome by the recent extension of a popular dead time correction method developed by Dytlewski. This extended dead time correction algorithm, named Dytlewski-Croft-Favalli (DCF), is detailed in reference Croft and Favalli (2017), which gives an extensive explanation of the theory andmore » implications of this new development. Dead time corrected results can then be used to assay SNM by inverting a set of extended point model equations which as well have only recently been formulated. Here, we discuss and present the experimental evaluation of practical feasibility of the DCF dead time correction algorithm to demonstrate its performance and applicability in nuclear safeguards applications. In order to test the validity and effectiveness of the dead time correction for quads and pents, 252Cf and SNM sources were measured in high efficiency neutron multiplicity counters at the Los Alamos National Laboratory (LANL) and the count rates were extracted up to the fifth order and corrected for dead time. To assess the DCF dead time correction, the corrected data is compared to traditional dead time correction treatment within INCC. In conclusion, the DCF dead time correction is found to provide adequate dead time treatment for broad range of count rates available in practical applications.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lockhart, M.; Henzlova, D.; Croft, S.
Over the past few decades, neutron multiplicity counting has played an integral role in Special Nuclear Material (SNM) characterization pertaining to nuclear safeguards. Current neutron multiplicity analysis techniques use singles, doubles, and triples count rates because a methodology to extract and dead time correct higher order count rates (i.e. quads and pents) was not fully developed. This limitation is overcome by the recent extension of a popular dead time correction method developed by Dytlewski. This extended dead time correction algorithm, named Dytlewski-Croft-Favalli (DCF), is detailed in reference Croft and Favalli (2017), which gives an extensive explanation of the theory andmore » implications of this new development. Dead time corrected results can then be used to assay SNM by inverting a set of extended point model equations which as well have only recently been formulated. Here, we discuss and present the experimental evaluation of practical feasibility of the DCF dead time correction algorithm to demonstrate its performance and applicability in nuclear safeguards applications. In order to test the validity and effectiveness of the dead time correction for quads and pents, 252Cf and SNM sources were measured in high efficiency neutron multiplicity counters at the Los Alamos National Laboratory (LANL) and the count rates were extracted up to the fifth order and corrected for dead time. To assess the DCF dead time correction, the corrected data is compared to traditional dead time correction treatment within INCC. In conclusion, the DCF dead time correction is found to provide adequate dead time treatment for broad range of count rates available in practical applications.« less
Modeling Delamination in Postbuckled Composite Structures Under Static and Fatigue Loads
NASA Technical Reports Server (NTRS)
Bisagni, Chiara; Brambilla, Pietro; Bavila, Carlos G.
2013-01-01
The ability of the Abaqus progressive Virtual Crack Closure Technique (VCCT) to model delamination in composite structures was investigated for static, postbuckling, and fatigue loads. Preliminary evaluations were performed using simple Double Cantilever Beam (DCB) and Mixed-Mode Bending (MMB) specimens. The nodal release sequences that describe the propagation of the delamination front were investigated. The effect of using a sudden or a gradual nodal release was evaluated by considering meshes aligned with the crack front as well as misaligned meshes. Fatigue simulations were then performed using the Direct Cyclic Fatigue (DCF) algorithm. It was found that in specimens such as the DCB, which are characterized by a nearly linear response and a pure fracture mode, the algorithm correctly predicts the Paris Law rate of propagation. However, the Abaqus DCF algorithm does not consider different fatigue propagation laws in different fracture modes. Finally, skin/stiffener debonding was studied in an aircraft fuselage subcomponent in which debonding occurs deep into post-buckling deformation. VCCT was shown to be a robust tool for estimating the onset propagation. However, difficulties were found with the ability of the current implementation of the Abaqus progressive VCCT to predict delamination propagation within structures subjected to postbuckling deformations or fatigue loads.
Biotic nitrosation of diclofenac in a soil aquifer system (Katari watershed, Bolivia).
Chiron, Serge; Duwig, Céline
2016-09-15
Up till now, the diclofenac (DCF) transformation into its nitrogen-derivatives, N-nitroso-DCF (NO-DCF) and 5-nitro-DCF (NO2-DCF), has been mainly investigated in wastewater treatment plant under nitrification or denitrification processes. This work reports, for the first time, an additional DCF microbial mediated nitrosation pathway of DCF in soil under strictly anoxic conditions probably involving codenitrification processes and fungal activities. This transformation pathway was investigated by using field observations data at a soil aquifer system (Katari watershed, Bolivia) and by carrying out soil slurry batch experiments. It was also observed for diphenylamine (DPA). Field measurements revealed the occurrence of NO-DCF, NO2-DCF and NO-DPA in groundwater samples at concentration levels in the 6-68s/L range. These concentration levels are more significant than those previously reported in wastewater treatment plant effluents taking into account dilution processes in soil. Interestingly, the p-benzoquinone imine of 5-OH-DCF was also found to be rather stable in surface water. In laboratory batch experiments under strictly anoxic conditions, the transformation of DCF and DPA into their corresponding N-nitroso derivatives was well correlated to denitrification processes. It was also observed that NO-DCF evolved into NO2-DCF while NO-DPA was stable. In vitro experiments showed that the Fisher-Hepp rearrangement could not account for NO2-DCF formation. One possible mechanism might be that NO-DCF underwent spontaneous NO loss to give the resulting intermediates diphenylaminyl radical or nitrenium cation which might evolve into NO2-DCF in presence of NO2 radical or nitrite ion, respectively. Copyright © 2016 Elsevier B.V. All rights reserved.
VHP - An environment for the remote visualization of heuristic processes
NASA Technical Reports Server (NTRS)
Crawford, Stuart L.; Leiner, Barry M.
1991-01-01
A software system called VHP is introduced which permits the visualization of heuristic algorithms on both resident and remote hardware platforms. The VHP is based on the DCF tool for interprocess communication and is applicable to remote algorithms which can be on different types of hardware and in languages other than VHP. The VHP system is of particular interest to systems in which the visualization of remote processes is required such as robotics for telescience applications.
NASA Astrophysics Data System (ADS)
Singh, Kundan; Siwal, Davinder
2018-04-01
A digital timing algorithm is explored for fast scintillator detectors, viz. LaBr3, BaF2, and BC501A. Signals were collected with CAEN 250 mega samples per second (MSPS) and 500 MSPS digitizers. The zero crossing time markers (TM) were obtained with a standard digital constant fraction timing (DCF) method. Accurate timing information is obtained using cubic spline interpolation of a DCF transient region sample points. To get the best time-of-flight (TOF) resolution, an optimization of DCF parameters is performed (delay and constant fraction) for each pair of detectors: (BaF2-LaBr3), (BaF2-BC501A), and (LaBr3-BC501A). In addition, the slope information of an interpolated DCF signal is extracted at TM position. This information gives a new insight to understand the broadening in TOF, obtained for a given detector pair. For a pair of signals having small relative slope and interpolation deviations at TM, leads to minimum time broadening. However, the tailing in TOF spectra is dictated by the interplay between the interpolation error and slope variations. Best TOF resolution achieved at the optimum DCF parameters, can be further improved by using slope parameter. Guided by the relative slope parameter, events selection can be imposed which leads to reduction in TOF broadening. While the method sets a trade-off between timing response and coincidence efficiency, it provides an improvement in TOF. With the proposed method, the improved TOF resolution (FWHM) for the aforementioned detector pairs are; 25% (0.69 ns), 40% (0.74 ns), 53% (0.6 ns) respectively, obtained with 250 MSPS, and corresponds to 12% (0.37 ns), 33% (0.72 ns), 35% (0.69 ns) respectively with 500 MSPS digitizers. For the same detector pair, event survival probabilities are; 57%, 58%, 51% respectively with 250 MSPS and becomes 63%, 57%, 68% using 500 MSPS digitizers.
Shah, Manish A; Janjigian, Yelena Y; Stoller, Ronald; Shibata, Stephen; Kemeny, Margaret; Krishnamurthi, Smitha; Su, Yungpo Bernard; Ocean, Allyson; Capanu, Marinela; Mehrotra, Bhoomi; Ritch, Paul; Henderson, Charles; Kelsen, David P
2015-11-20
Docetaxel, cisplatin, and fluorouracil (DCF) is a standard first-line three-drug chemotherapy regimen for advanced gastric or gastroesophageal junction (GEJ) adenocarcinoma and is associated with significant toxicity. We examined the safety and efficacy of a modified DCF (mDCF) regimen in a randomized multicenter phase II study. Previously untreated patients with metastatic gastric or GEJ adenocarcinoma were randomly assigned to receive either mDCF (fluorouracil 2,000 mg/m2 intravenously [IV] over 48 hours, docetaxel 40 mg/m2 IV on day 1, cisplatin 40 mg/m2 IV on day 3, every 2 weeks) or parent DCF (docetaxel 75 mg/m2, cisplatin 75 mg/m2, and fluorouracil 750 mg/m2 IV over 5 days with granulocyte colony-stimulating factor, every 3 weeks). The study had 90% power to differentiate between 6-month progression-free survival of 26% and 43%, with type I and II error rates of 10% each. An early stopping rule for toxicity was included, defined as grade 3 to 4 adverse event rate > 70% in the first 3 months. From November 2006 to June 2010, 85 evaluable patients were enrolled (male, n = 61; female, n = 24; median age, 58 years; Karnofsky performance status, 90%; GEJ, n = 28; gastric, 57). mDCF (n = 54) toxicity rates included 54% grade 3 to 4 toxicity (22% hospitalized) within the first 3 months and 76% grade 3 to 4 toxicity over the course of treatment. The DCF arm (n = 31) closed early because of toxicity, with rates of 71% grade 3 to 4 toxicity (52% hospitalized) within 3 months and 90% grade 3 to 4 toxicity over the course of treatment. Six-month PFS was 63% (95% CI, 48% to 75%) for mDCF and 53% (95% CI, 34% to 69%) for DCF. Median overall survival was improved for mDCF (18.8 v 12.6 months; P = .007). mDCF is less toxic than parent DCF, even when supported with growth factors, and is associated with improved efficacy. mDCF should be considered a standard first-line option for patients with metastatic gastric or GEJ adenocarcinoma.
NASA Astrophysics Data System (ADS)
Beaudette, Kathy; Lo, William; Villiger, Martin; Shishkov, Milen; Godbout, Nicolas; Bouma, Brett E.; Boudoux, Caroline
2016-03-01
There is a strong clinical need for an optical coherence tomography (OCT) system capable of delivering concurrent coagulation light enabling image-guided dynamic laser marking for targeted collection of biopsies, as opposed to a random sampling, to reduce false-negative findings. Here, we present a system based on double-clad fiber (DCF) capable of delivering pulsed laser light through the inner cladding while performing OCT through the core. A previously clinically validated commercial OCT system (NVisionVLE, Ninepoint Medical) was adapted to enable in vivo esophageal image-guided dynamic laser marking. An optimized DCF coupler was implemented into the system to couple both modalities into the DCF. A DCF-based rotary joint was used to couple light to the spinning DCF-based catheter for helical scanning. DCF-based OCT catheters, providing a beam waist diameter of 62μm at a working distance of 9.3mm, for use with a 17-mm diameter balloon sheath, were used for ex vivo imaging of a swine esophagus. Imaging results using the DCF-based clinical system show an image quality comparable with a conventional system with minimal crosstalk-induced artifacts. To further optimize DCF catheter optical design in order to achieve single-pulse marking, a Zemax model of the DCF output and its validation are presented.
Rigobello, Eliane Sloboda; Dantas, Angela Di Bernardo; Di Bernardo, Luiz; Vieira, Eny Maria
2013-06-01
This study was carried out to evaluate the efficiency of conventional drinking water treatment processes with and without pre-oxidation with chlorine and chlorine dioxide and the use of granular activated carbon (GAC) filtration for the removal of diclofenac (DCF). Water treatment was performed using the Jar test with filters on a lab scale, employing nonchlorinated artesian well water prepared with aquatic humic substances to yield 20HU true color, kaolin turbidity of 70 NTU and 1mgL(-1) DCF. For the quantification of DCF in water samples, solid phase extraction and HPLC-DAD methods were developed and validated. There was no removal of DCF in coagulation with aluminum sulfate (3.47mgAlL(-1) and pH=6.5), flocculation, sedimentation and sand filtration. In the treatment with pre-oxidation and disinfection, DCF was partially removed, but the concentration of dissolved organic carbon (DOC) was unchanged and byproducts of DCF were observed. Chlorine dioxide was more effective than chorine in oxidizing DCF. In conclusion, the identification of DCF and DOC in finished water indicated the incomplete elimination of DCF through conventional treatments. Nevertheless, conventional drinking water treatment followed by GAC filtration was effective in removing DCF (⩾99.7%). In the oxidation with chlorine, three byproducts were tentatively identified, corresponding to a hydroxylation, aromatic substitution of one hydrogen by chlorine and a decarboxylation/hydroxylation. Oxidation with chlorine dioxide resulted in only one byproduct (hydroxylation). Copyright © 2013 Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kakita, Hiroki; Department of Pediatrics and Neonatology, Nagoya City University Graduate School of Medical Sciences, 1 Kawasumi, Mizuho-cho, Mizuho-ku, Nagoya 467-8601; Department of Neonatology, Aichi Human Service Center Central Hospital, 713-8 Kamiya-Cho, Kasugai 480-0392
2009-07-01
Recently, the number of reports of encephalitis/encephalopathy associated with influenza virus has increased. In addition, the use of a non-steroidal anti-inflammatory drug, diclofenac sodium (DCF), is associated with a significant increase in the mortality rate of influenza-associated encephalopathy. Activated astrocytes are a source of nitric oxide (NO), which is largely produced by inducible NO synthase (iNOS) in response to proinflammatory cytokines. Therefore, we investigated whether DCF enhances nitric oxide production in astrocytes stimulated with proinflammatory cytokines. We stimulated cultured rat astrocytes with three cytokines, interleukin-1{beta}, tumor necrosis factor-{alpha} and interferon-{gamma}, and then treated the astrocytes with DCF or acetaminophen (N-acetyl-p-aminophenol:more » APAP). iNOS and NO production in astrocyte cultures were induced by proinflammatory cytokines. The addition of DCF augmented NO production, but the addition of APAP did not. NF-{kappa}B inhibitors SN50 and MG132 inhibited iNOS gene expression in cytokine-stimulated astrocytes with or without DCF. Similarly, NF-{kappa}B p65 Stealth small interfering RNA suppressed iNOS gene expression in cytokine-stimulated astrocytes with or without DCF. LDH activity and DAPI staining showed that DCF induces cell damage in cytokine-stimulated astrocytes. An iNOS inhibitor, L-NMMA, inhibited the cytokine- and DCF-induced cell damage. In conclusion, this study demonstrates that iNOS and NO are induced in astrocyte cultures by proinflammatory cytokines. Addition of DCF further augments NO production. This effect is mediated via NF-{kappa}B signaling and leads to cell damage. The enhancement of DCF on NO production may explain the significant increase in the mortality rate of influenza-associated encephalopathy in patients treated with DCF.« less
Simulation and video animation of canal flushing created by a tide gate
Schoellhamer, David H.
1988-01-01
A tide-gate algorithm was added to a one-dimensional unsteady flow model that was calibrated, verified, and used to determine the locations of as many as five tide gates that would maximize flushing in two canal systems. Results from the flow model were used to run a branched Lagrangian transport model to simulate the flushing of a conservative constituent from the canal systems both with and without tide gates. A tide gate produces a part-time riverine flow through the canal system that improves flushing along the flow path created by the tide gate. Flushing with no tide gates and with a single optimally located tide gate are shown with a video animation.
Toufexi, Eirini; Dailianis, Stefanos; Vlastos, Dimitris; Manariotis, Ioannis D
2016-06-01
The present study investigates the toxic behavior of diclofenac (DCF) before and after its ultrasound (US) treatment, as well as the involvement of intracellular target molecules, such as NADPH oxidase and NO synthase, in the DCF-induced adverse effects on hemocytes of mussel Mytilus galloprovincialis. In this context, appropriate volumes (350 and 500mL) of DCF solutions (at concentrations of 2, 2.5, 5 and 10mgL(-1)) were treated under different ultrasound operating conditions (frequency at 582 and 862kHz, electric power density at 133 and 167W) for assessing US method efficiency. In parallel, DCF and US DCF-mediated cytotoxic (in terms of cell viability measured with the use of neutral red uptake/NRU method), oxidative (in terms of superoxide anions/(.)O2(-), nitric oxides such as NO2(-) and lipid peroxidation products, such as malondialdehyde/MDA content) and genotoxic (DNA damage measured by the use of Comet assay method) effects were investigated in hemocytes exposed for 1h to 5, 10 and 100ngL(-1) and 1, 10 and 20μgL(-1) of DCF. The involvement of NADPH oxidase and NO synthase to the DCF-induced toxicity was further investigated by the use of 10μΜ L-NAME, a NO synthase inhibitor and 10μΜ DPI, a NADPH oxidase inhibitor. According to the results, 350mL of 2mgL(-1) DCF showed higher degradation (>50%) under 167W electric power density and frequency at 862kHz for 120min, compared to degradation in all other cases, followed by a significant elimination of its toxicity. Specifically, US DCF-treated hemocytes showed a significant attenuation of DCF-mediated cytotoxic, oxidative and genotoxic effects, which appeared to be caused by NADPH oxidase and NO synthase activation, since their inhibition was followed by a significant elimination of (.)O2(-) and NO2(-) generation and the concomitant oxidative damage within cells. The results of the present study showed for the first time that unspecific mode of action of DCF, associated with the induction of NADPH oxidase and NO synthase in mussel hemocytes, could be significantly diminished after partial US degradation of DCF, at least under optimized operating conditions currently tested. Copyright © 2016 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kakita, Hiroki; Department of Pediatrics and Neonatology, Nagoya City University Graduate School of Medical Sciences, 1 Kawasumi, Mizuho-cho, Mizuho-ku, Nagoya 467-8601; Aoyama, Mineyoshi, E-mail: ao.mine@med.nagoya-cu.ac.jp
Influenza-associated encephalopathy (IAE) is a central nervous system complication with a high mortality rate, which is increased significantly by the non-steroidal anti-inflammatory drug diclofenac sodium (DCF). In the present study, we investigated the effects of DCF on brain immune cells (i.e. microglia) stimulated with three proinflammatory cytokines, namely tumor necrosis factor-α, interleukin-1β, and interferon-γ. Similar to previous findings in astrocytes, all three cytokines induced the expression of inducible NO synthase (iNOS), as well as NO production, in microglia. The addition of DCF to the culture system augmented iNOS expression and NO production. Immunocytochemical analysis and the phagocytosis assay revealed thatmore » cytokine treatment induced morphological changes to and phagocytosis by the microglia. The addition of DCF to the culture system enhanced microglial activation, as well as the phagocytic activity of cytokine-stimulated microglia. Inhibitors of nuclear factor (NF)-κB inhibited iNOS gene expression in cytokine-stimulated microglia with or without DCF, suggesting that the NF-κB pathway is one of the main signaling pathways involved. The iNOS inhibitor N{sup G}-monomethyl-L-arginine (L-NMMA) reduced both cytokine-induced phagocytosis and phagocytosis induced by the combination of cytokines plus DCF. Furthermore, the NO donor sodium nitroprusside induced phagocytosis, indicating that NO production is a key regulator of microglial phagocytosis. In conclusion, DCF acts synergistically with proinflammatory cytokines to increase the production of NO in microglia, leading to phagocytic activity of the activated microglia. These findings, together with previous observations regarding astrocytes, may explain the significant increase in mortality of IAE patients treated with DCF. - Highlights: ► Influenza-associated encephalopathy (IAE) is associated with a high mortality rate. ► Hyperimmunization in the brain is believed to be responsible for IAE. ► The use of diclofenac sodium (DCF) increases the mortality of IAE. ► DCF enhances the cytokine-induced phagocytosis of microglia, brain immune cells. ► DCF-enhanced activation of microglia may explain the greater mortality rate of IAE.« less
Adsorption and removal of clofibric acid and diclofenac from water with MIEX resin.
Lu, Xian; Shao, Yisheng; Gao, Naiyun; Chen, Juxiang; Zhang, Yansen; Wang, Qiongfang; Lu, Yuqi
2016-10-01
This study demonstrates the use of MIEX resin as an efficient adsorbent for the removal of clofibric acid (CA) and diclofenac (DCF). The adsorption performance of CA and DCF are investigated by a batch mode in single-component or bi-component adsorption system. Various factors influencing the adsorption of CA and DCF, including initial concentration, contact time, adsorbent dosage, initial solution pH, agitation speed, natural organic matter and coexistent anions are studied. The Langmuir model can well describe CA adsorption in single-component system, while the Freundlich model gives better fitting in bi-component system. The DCF adsorption can be well fitted by the Freundlich model in both systems. Thermodynamic analyses show that the adsorption of CA and DCF is an endothermic (ΔH(o) > 0), entropy driven (ΔS(o) > 0) process and more randomness exists in the DCF adsorption process. The values of Gibbs free energy (ΔG(o) < 0) indicate the adsorption of DCF is spontaneous but nonspontaneous (ΔG(o) > 0) for CA adsorption. The kinetic data suggest the adsorption of CA and DCF follow the pseudo-first-order model in both systems and the intra-particle is not the unique rate-limiting step. The adsorption process is controlled simultaneously by external mass transfer and surface diffusion according to the surface diffusion modified Biot number (Bis) ranging from 1.06 to 26.15. Moreover, the possible removal mechanism for CA and DCF is respectively proposed based on the ion exchange stoichiometry. Copyright © 2016 Elsevier Ltd. All rights reserved.
Biodegradation of Diclofenac by the bacterial strain Labrys portucalensis F11.
Moreira, Irina S; Bessa, Vânia S; Murgolo, Sapia; Piccirillo, Clara; Mascolo, Giuseppe; Castro, Paula M L
2018-05-15
Diclofenac (DCF) is a widely used non-steroidal anti-inflammatory pharmaceutical which is detected in the environment at concentrations which can pose a threat to living organisms. In this study, biodegradation of DCF was assessed using the bacterial strain Labrys portucalensis F11. Biotransformation of 70% of DCF (1.7-34 μM), supplied as the sole carbon source, was achieved in 30 days. Complete degradation was reached via co-metabolism with acetate, over a period of 6 days for 1.7 µM and 25 days for 34 μM of DCF. The detection and identification of biodegradation intermediates was performed by UPLC-QTOF/MS/MS. The chemical structure of 12 metabolites is proposed. DCF degradation by strain F11 proceeds mainly by hydroxylation reactions; the formation of benzoquinone imine species seems to be a central step in the degradation pathway. Moreover, this is the first report that identified conjugated metabolites, resulting from sulfation reactions of DCF by bacteria. Stoichiometric liberation of chlorine and no detection of metabolites at the end of the experiments are strong indications of complete degradation of DCF by strain F11. To the best of our knowledge this is the first report that points to complete degradation of DCF by a single bacterial strain isolated from the environment. Copyright © 2018 Elsevier Inc. All rights reserved.
Cheng, Hanyang; Song, Dean; Liu, Huijuan; Qu, Jiuhui
2015-10-01
In this work, the fate of diclofenac (DCF) during permanganate (Mn(VII)) oxidation was investigated at environmentally relevant pH conditions (from 5 to 9). The batch experiments showed that the kinetics of the Mn(VII)/DCF reaction follows a second-order rate law with an apparent rate constant of 1.57±0.02 M(-1) s(-1) at pH 7 and 20 °C. The half-value of DCF was calculated to be 37.5 min, when the concentration of Mn(VII) (0.4 mM) was 20-fold excess of DCF. The pH-dependence of the reaction kinetics was investigated, and the DCF reactivity with Mn(VII) was found to decrease with increasing pH. The second-order rate constants were then quantitatively described by incorporating the species distribution of DCF. A lower reactivity of the anionic DCF (DCF(-)) in comparison with its neutral counterpart (DCF(0)) was most likely attributable to the interaction between the ionized carboxylate group and amine nitrogen position, which can reduce the nucleophilicity of amine nitrogen by inductive and resonance effects. Moreover, a range of degradation products and the corresponding structures were proposed on the basis of the LC-Q-TOF-MS analysis. A detailed ring-opening reaction mechanism was proposed as follows: Mn(VII) acts as an electrophile to attack the amine moiety, leading to the formation of the primary intermediate products 2,6-dichloroaniline and 5-hydroxy-diclofenac, which can be further transformed. The further degradation proceeded through a multistep process including ring-opening, decarboxylation, hydroxylation, and cyclation reactions. Copyright © 2014 Elsevier Ltd. All rights reserved.
SWIFT, LUTHER M.; SARVAZYAN, NARINE
2011-01-01
Localization and staining features of the oxidant-sensitive fluorescent probe 2 7 - dichlorofluorescin (DCFH) were evaluated in isolated cardiac muscle cells. Cardiomyocytes rapidly accumulated the probe and retained steady levels of DCFH and its highly fluorescent oxidized product dichlorofluorescein (DCF) in probe-free medium for 1.5 h. DCF was associated with mitochondria and was released by the proton ionophore carbonyl cyanide m-chlorophenylhydrazone but not by saponin, which permeabilizes the plasma membrane. A mitochondrial distribution of DCF was also suggested by experiments with the mitochondrial marker MitoTracker Red, in which quenching was observed between DCF and MitoTracker Red in live cells. Isolated cardiac mitochondria rapidly accumulated DCF, and high micromolar concentrations of the probe inhibited ADP-stimulated respiration rate. The study provides an information base essential for the interpretation and design of experiments with DCF as a marker of oxidative stress in cardiac muscle and reveals preferential localization of the probe in mitochondria. PMID:10710368
Kummerová, Marie; Zezulka, Štěpán; Babula, Petr; Tříska, Jan
2016-01-25
Lemna minor is often used in environmental risk assessment and it can be supposed that usually evaluated parameters will be reliable even for assessing the risk of pharmaceuticals. Subtle changes in duckweed plant number, biomass production, and leaf area size induced by 10-day-exposure to diclofenac (DCF) and paracetamol (PCT) (0.1, 10, and 100 μg/L), excepting 100 μg/L DCF, are in contrast with considerable changes on biochemical and histochemical level. Both drugs caused a decrease in content of photosynthetic pigments (by up to 50%), an increase in non-photochemical quenching (by 65%) and decrease in relative chlorophyll fluorescence decay values (by up to 90% with DCF). Both DCF and especially PCT increased amount of reactive nitrogen and oxygen species in roots. DCF-induced effects included mainly increased lipid peroxidation (by 78%), disturbation in membrane integrity and lowering both oxidoreductase and dehydrogenase activities (by 30%). PCT increased the content of soluble proteins and phenolics. Higher concentrations of both DCF and PCT increased the levels of oxidised ascorbate (by 30%) and oxidised thiols (by up to 84% with DCF). Glutathion-reductase activity was elevated by both pharmaceuticals (nearly by 90%), glutathion-S-transferase activity increased mainly with PCT (by 22%). The early and sensitive indicators of DCF and PCT phytotoxicity stress in duckweed are mainly the changes in biochemical processes, connected with activation of defense mechanisms against oxidative stress. Copyright © 2015 Elsevier B.V. All rights reserved.
Pisutha-Arnond, N; Chan, V W L; Iyer, M; Gavini, V; Thornton, K
2013-01-01
We introduce a new approach to represent a two-body direct correlation function (DCF) in order to alleviate the computational demand of classical density functional theory (CDFT) and enhance the predictive capability of the phase-field crystal (PFC) method. The approach utilizes a rational function fit (RFF) to approximate the two-body DCF in Fourier space. We use the RFF to show that short-wavelength contributions of the two-body DCF play an important role in determining the thermodynamic properties of materials. We further show that using the RFF to empirically parametrize the two-body DCF allows us to obtain the thermodynamic properties of solids and liquids that agree with the results of CDFT simulations with the full two-body DCF without incurring significant computational costs. In addition, the RFF can also be used to improve the representation of the two-body DCF in the PFC method. Last, the RFF allows for a real-space reformulation of the CDFT and PFC method, which enables descriptions of nonperiodic systems and the use of nonuniform and adaptive grids.
Oxidation of diclofenac by potassium ferrate (VI): reaction kinetics and toxicity evaluation.
Wang, Yingling; Liu, Haijin; Liu, Guoguang; Xie, Youhai; Gao, Shuyan
2015-02-15
The reaction kinetics and toxicity of diclofenac (DCF) oxidation by ferrate (VI) under simulated water disinfection conditions were investigated. Experimental results indicated that the reaction between DCF and Fe(VI) followed first-order kinetics with respect to each reactant. Furthermore, the effects of pH and temperature on DCF oxidation by Fe(VI) were elucidated using a systematic examination. The apparent second-order rate constants (kapp) increased significantly from 2.54 to 11.6M(-1)s(-1), as the pH of the solution decreased from 11.0 to 7.0, and the acid-base equilibriums of Fe(VI) and DCF were proposed to explain the pH dependence of kapp. The acute toxicity of DCF solution during Fe(VI) oxidation was evaluated using a Microtox bioassay. Overall, the DCF degradation process resulted in a rapid increase of the inhibition rate of luminescent bacteria. These toxicity tests suggest that the formation of enhanced toxic intermediates during the Fe(VI) disinfection process may pose potential health risk to consumers. Copyright © 2014 Elsevier B.V. All rights reserved.
NASA Technical Reports Server (NTRS)
Millman, Daniel R.
2017-01-01
Air Data Systems (FADS) are becoming more prevalent on re-entry vehicles, as evi- denced by the Mars Science Laboratory and the Orion Multipurpose Crew Vehicle. A FADS consists of flush-mounted pressure transducers located at various locations on the fore-body of a flight vehicle or the heat shield of a re-entry capsule. A pressure model converts the pressure readings into useful air data quantities. Two algorithms for converting pressure readings to air data have become predominant- the iterative Least Squares State Estimator (LSSE) and the Triples Algorithm. What follows herein is a new algorithm that takes advantage of the best features of both the Triples Algorithm and the LSSE. This approach employs the potential flow model and strategic differencing of the Triples Algorithm to obtain the defective flight angles; however, the requirements on port placement are far less restrictive, allowing for configurations that are considered optimal for a FADS.
Kinetics and mechanism of diclofenac removal using ferrate(VI): roles of Fe3+, Fe2+, and Mn2.
Zhao, Junfeng; Wang, Qun; Fu, Yongsheng; Peng, Bo; Zhou, Gaofeng
2018-06-01
In this study, the effect of Fe 3+ , Fe 2+ , and Mn 2+ dose, solution pH, reaction temperature, background water matrix (i.e., inorganic anions, cations, and natural organic matters (NOM)), and the kinetics and mechanism for the reaction system of Fe(VI)/Fe 3+ , Fe(VI)/Fe 2+ , and Fe(VI)/Mn 2+ were investigated systematically. Traces of Fe 3+ , Fe 2+ , and Mn 2+ promoted the DCF removal by Fe(VI) significantly. The pseudo-first-order rate constant (k obs ) of DCF increased with decreasing pH (9-6) and increasing temperature (10-30 °C) due to the gradually reduced stability and enhanced reactivity of Fe(VI). Cu 2+ and Zn 2+ ions evidently improved the DCF removal, while CO 3 2- restrained it. Besides, SO 4 2- , Cl - , NO 3 - , Mg 2+ , and Ca 2+ almost had no influence on the degradation of DCF by Fe(VI)/Fe 3+ , Fe(VI)/Fe 2+ , and Fe(VI)/Mn 2+ within the tested concentration. The addition of 5 or 20 mg L -1 NOM decreased the removal efficiency of DCF. Moreover, Fe 2 O 3 and Fe(OH) 3 , the by-products of Fe(VI), slightly inhibited the DCF removal, while α-FeOOH, another by-product of Fe(VI), showed no influence at pH 7. In addition, MnO 2 and MnO 4 - , the by-products of Mn 2+ , enhanced the DCF degradation due to catalysis and superposition of oxidation capacity, respectively. This study indicates that Fe 3+ and Fe 2+ promoted the DCF removal mainly via the self-catalysis for Fe(VI), and meanwhile, the catalysis of Mn 2+ and the effect of its by-products (i.e., MnO 2 and MnO 4 - ) contributed synchronously for DCF degradation. Graphical abstract ᅟ.
LoGuidice, Amanda; Wallace, Bret D; Bendel, Lauren; Redinbo, Matthew R; Boelsterli, Urs A
2012-05-01
Small intestinal mucosal injury is a frequent adverse effect caused by nonsteroidal anti-inflammatory drugs (NSAIDs). The underlying mechanisms are not completely understood, but topical (luminal) effects have been implicated. Many carboxylic acid-containing NSAIDs, including diclofenac (DCF), are metabolized to acyl glucuronides (AGs), and/or ether glucuronides after ring hydroxylation, and exported into the biliary tree. In the gut, these conjugates are cleaved by bacterial β-glucuronidase, releasing the potentially harmful aglycone. We first confirmed that DCF-AG was an excellent substrate for purified Escherichia coli β-D-glucuronidase. Using a previously characterized novel bacteria-specific β-glucuronidase inhibitor (Inhibitor-1), we then found that the enzymatic hydrolysis of DCF-AG in vitro was inhibited concentration dependently (IC₅₀ ∼164 nM). We next hypothesized that pharmacologic inhibition of bacterial β-glucuronidase would reduce exposure of enterocytes to the aglycone and, as a result, alleviate enteropathy. C57BL/6J mice were administered an ulcerogenic dose of DCF (60 mg/kg i.p.) with or without oral pretreatment with Inhibitor-1 (10 μg per mouse, b.i.d.). Whereas DCF alone caused the formation of numerous large ulcers in the distal parts of the small intestine and increased (2-fold) the intestinal permeability to fluorescein isothiocyanate-dextran, Inhibitor-1 cotreatment significantly alleviated mucosal injury and reduced all parameters of enteropathy. Pharmacokinetic profiling of DCF plasma levels in mice revealed that Inhibitor-1 coadministration did not significantly alter the C(max), half-life, or area under the plasma concentration versus time curve of DCF. Thus, highly selective pharmacologic targeting of luminal bacterial β-D-glucuronidase by a novel class of small-molecule inhibitors protects against DCF-induced enteropathy without altering systemic drug exposure.
LoGuidice, Amanda; Wallace, Bret D.; Bendel, Lauren; Redinbo, Matthew R.
2012-01-01
Small intestinal mucosal injury is a frequent adverse effect caused by nonsteroidal anti-inflammatory drugs (NSAIDs). The underlying mechanisms are not completely understood, but topical (luminal) effects have been implicated. Many carboxylic acid-containing NSAIDs, including diclofenac (DCF), are metabolized to acyl glucuronides (AGs), and/or ether glucuronides after ring hydroxylation, and exported into the biliary tree. In the gut, these conjugates are cleaved by bacterial β-glucuronidase, releasing the potentially harmful aglycone. We first confirmed that DCF-AG was an excellent substrate for purified Escherichia coli β-d-glucuronidase. Using a previously characterized novel bacteria-specific β-glucuronidase inhibitor (Inhibitor-1), we then found that the enzymatic hydrolysis of DCF-AG in vitro was inhibited concentration dependently (IC50 ∼164 nM). We next hypothesized that pharmacologic inhibition of bacterial β-glucuronidase would reduce exposure of enterocytes to the aglycone and, as a result, alleviate enteropathy. C57BL/6J mice were administered an ulcerogenic dose of DCF (60 mg/kg i.p.) with or without oral pretreatment with Inhibitor-1 (10 μg per mouse, b.i.d.). Whereas DCF alone caused the formation of numerous large ulcers in the distal parts of the small intestine and increased (2-fold) the intestinal permeability to fluorescein isothiocyanate-dextran, Inhibitor-1 cotreatment significantly alleviated mucosal injury and reduced all parameters of enteropathy. Pharmacokinetic profiling of DCF plasma levels in mice revealed that Inhibitor-1 coadministration did not significantly alter the Cmax, half-life, or area under the plasma concentration versus time curve of DCF. Thus, highly selective pharmacologic targeting of luminal bacterial β-d-glucuronidase by a novel class of small-molecule inhibitors protects against DCF-induced enteropathy without altering systemic drug exposure. PMID:22328575
Zhang, Yalei; Shen, Zhe; Dai, Chaomeng; Zhou, Xuefei
2014-11-01
A novel-modified magnetic chitosan adsorbent was used to remove selected pharmaceuticals, i.e., diclofenac (DCF) and clofibric acid (CA) and carbamazepine (CBZ), from aqueous solutions. The characterization of magnetic chitosan was achieved by scanning electron and transmission electron microscopy, X-ray diffraction, X-ray photoelectron spectroscopy, vibrating sample magnetometer, and nitrogen sorption analysis. The magnetic chitosan had effective sorption affinity for DCF and CA but no sorption of CBZ was observed. The sorption capacities of CA and DCF in the individual solutions were 191.2 and 57.5 mg/g, respectively. While in mixed solution, DCF showed higher sorption affinity. Sorption kinetics indicated a quick equilibrium reached within 2 min. Lower solution pH values were found to be advantageous for the adsorption process. The sorption efficacy of CA declined significantly with increasing inorganic salt concentration. However, sorption performance of DCF was stable under different ionic strength conditions.
Comparative Study on a Solving Model and Algorithm for a Flush Air Data Sensing System
Liu, Yanbin; Xiao, Dibo; Lu, Yuping
2014-01-01
With the development of high-performance aircraft, precise air data are necessary to complete challenging tasks such as flight maneuvering with large angles of attack and high speed. As a result, the flush air data sensing system (FADS) was developed to satisfy the stricter control demands. In this paper, comparative stuides on the solving model and algorithm for FADS are conducted. First, the basic principles of FADS are given to elucidate the nonlinear relations between the inputs and the outputs. Then, several different solving models and algorithms of FADS are provided to compute the air data, including the angle of attck, sideslip angle, dynamic pressure and static pressure. Afterwards, the evaluation criteria of the resulting models and algorithms are discussed to satisfy the real design demands. Futhermore, a simulation using these algorithms is performed to identify the properites of the distinct models and algorithms such as the measuring precision and real-time features. The advantages of these models and algorithms corresponding to the different flight conditions are also analyzed, furthermore, some suggestions on their engineering applications are proposed to help future research. PMID:24859025
Comparative study on a solving model and algorithm for a flush air data sensing system.
Liu, Yanbin; Xiao, Dibo; Lu, Yuping
2014-05-23
With the development of high-performance aircraft, precise air data are necessary to complete challenging tasks such as flight maneuvering with large angles of attack and high speed. As a result, the flush air data sensing system (FADS) was developed to satisfy the stricter control demands. In this paper, comparative stuides on the solving model and algorithm for FADS are conducted. First, the basic principles of FADS are given to elucidate the nonlinear relations between the inputs and the outputs. Then, several different solving models and algorithms of FADS are provided to compute the air data, including the angle of attck, sideslip angle, dynamic pressure and static pressure. Afterwards, the evaluation criteria of the resulting models and algorithms are discussed to satisfy the real design demands. Futhermore, a simulation using these algorithms is performed to identify the properites of the distinct models and algorithms such as the measuring precision and real-time features. The advantages of these models and algorithms corresponding to the different flight conditions are also analyzed, furthermore, some suggestions on their engineering applications are proposed to help future research.
Stable Algorithm For Estimating Airdata From Flush Surface Pressure Measurements
NASA Technical Reports Server (NTRS)
Whitmore, Stephen, A. (Inventor); Cobleigh, Brent R. (Inventor); Haering, Edward A., Jr. (Inventor)
2001-01-01
An airdata estimation and evaluation system and method, including a stable algorithm for estimating airdata from nonintrusive surface pressure measurements. The airdata estimation and evaluation system is preferably implemented in a flush airdata sensing (FADS) system. The system and method of the present invention take a flow model equation and transform it into a triples formulation equation. The triples formulation equation eliminates the pressure related states from the flow model equation by strategically taking the differences of three surface pressures, known as triples. This triples formulation equation is then used to accurately estimate and compute vital airdata from nonintrusive surface pressure measurements.
NASA Astrophysics Data System (ADS)
Zhou, Lei; Li, Zhengying; Xiang, Na; Bao, Xiaoyi
2018-06-01
A high speed quasi-distributed demodulation method based on the microwave photonics and the chromatic dispersion effect is designed and implemented for weak fiber Bragg gratings (FBGs). Due to the effect of dispersion compensation fiber (DCF), FBG wavelength shift leads to the change of the difference frequency signal at the mixer. With the way of crossing microwave sweep cycle, all wavelengths of cascade FBGs can be high speed obtained by measuring the frequencies change. Moreover, through the introduction of Chirp-Z and Hanning window algorithm, the analysis of difference frequency signal is achieved very well. By adopting the single-peak filter as a reference, the length disturbance of DCF caused by temperature can be also eliminated. Therefore, the accuracy of this novel method is greatly improved, and high speed demodulation of FBGs can easily realize. The feasibility and performance are experimentally demonstrated using 105 FBGs with 0.1% reflectivity, 1 m spatial interval. Results show that each grating can be distinguished well, and the demodulation rate is as high as 40 kHz, the accuracy is about 8 pm.
Determination of Algorithm Parallelism in NP Complete Problems for Distributed Architectures
1990-03-05
12 structure STACK declare OpenStack (S-.NODE **TopPtr) -+TopPtrI FlushStack(S.-NODE **TopPtr) -*TopPtr PushOnStack(S-.NODE **TopPtr, ITEM *NewltemPtr...OfCoveringSets, CoveringSets, L, Best CoverTime, Vertex, Set3end SCND ADT B.26 structure STACKI declare OpenStack (S-NODE **TopPtr) -+TopPtr FlushStack(S
Zhang, N; Li, J M; Liu, G G; Chen, X L; Jiang, K
2017-05-01
Diclofenac (DCF) is one of the most frequently detected pharmaceuticals in various water samples. This paper studied the effects of aquatic environmental factors (pH, temperature and dissolved organic matter) on photodegradation of DCF under simulated sunlight. The results demonstrate that degradation pathways proceed via pseudo first-order kinetics in all cases and the photodegradation of DCF by simulated sunlight. Thermodynamic study indicated that the photodegradation course is spontaneous, exothermic and irreversible. The rate constant gradually increased when the pH increased from 3 to 5, then decreased when the pH increased from 5 to 8, and finally increased when the pH further increased from 8 to 12. Humic acid inhibited the photodegradation of DCF. Three kinds of main degradation products were observed by high performance liquid chromatography/mass spectrometry and the degradation pathways were suggested. A toxicity test using Photobacterium phosphoreum T 3 Sp indicated the generation of some more toxic products than DCF.
Landry, Kelly A; Sun, Peizhe; Huang, Ching-Hua; Boyer, Treavor H
2015-01-01
This research advances the knowledge of ion-exchange of four non-steroidal anti-inflammatory drugs (NSAIDs) - diclofenac (DCF), ibuprofen (IBP), ketoprofen (KTP), and naproxen (NPX) - and one analgesic drug-paracetamol (PCM) - by strong-base anion exchange resin (AER) in synthetic ureolyzed urine. Freundlich, Langmuir, Dubinin-Astakhov, and Dubinin-Radushkevich isotherm models were fit to experimental equilibrium data using nonlinear least squares method. Favorable ion-exchange was observed for DCF, KTP, and NPX, whereas unfavorable ion-exchange was observed for IBP and PCM. The ion-exchange selectivity of the AER was enhanced by van der Waals interactions between the pharmaceutical and AER as well as the hydrophobicity of the pharmaceutical. For instance, the high selectivity of the AER for DCF was due to the combination of Coulombic interactions between quaternary ammonium functional group of resin and carboxylate functional group of DCF, van der Waals interactions between polystyrene resin matrix and benzene rings of DCF, and possibly hydrogen bonding between dimethylethanol amine functional group side chain and carboxylate and amine functional groups of DCF. Based on analysis of covariance, the presence of multiple pharmaceuticals did not have a significant effect on ion-exchange removal when the NSAIDs were combined in solution. The AER reached saturation of the pharmaceuticals in a continuous-flow column at varying bed volumes following a decreasing order of DCF > NPX ≈ KTP > IBP. Complete regeneration of the column was achieved using a 5% (m/m) NaCl, equal-volume water-methanol solution. Results from multiple treatment and regeneration cycles provide insight into the practical application of pharmaceutical ion-exchange in ureolyzed urine using AER.
Bani-Yaseen, Abdulilah Dawoud
2016-08-21
The effects of noncovalent interactions, namely halogen and hydrogen bonding, on the photochemical conversion of the photosensitizing drug diclofenac (DCF) in solution were investigated computationally. Both explicit and implicit solvent effects were qualitatively and quantitatively assessed employing the DFT/6-31+G(d) and SQM(PM7) levels of theory. Full geometry optimizations were performed in solution for the reactant DCF, hypothesized radical-based intermediates, and the main product at both levels of theories. Notably, in good agreement with previous experimental results concerning the intermolecular halogen bonding of DCF, the SQM(PM7) method revealed different values for d(ClO, Å) and ∠(C-ClO, °) for the two chlorine-substituents of DCF, with values of 2.63 Å/162° and 3.13 Å/142° for the trans and cis orientations, respectively. Employing the DFT/6-31+G(d) method with implicit solvent effects was not conclusive; however, explicit solvent effects confirmed the key contribution of hydrogen and halogen bonding in stabilizing/destabilizing the reactant and hypothesized intermediates. Interestingly, the obtained results revealed that a protic solvent such as water can increase the rate of photocyclization of DCF not only through hydrogen bonding effects, but also through halogen bonding. Furthermore, the atomic charges of atoms majorly involved in the photocyclization of DCF were calculated using different methods, namely Mulliken, Hirshfeld, and natural bond orbital (NBO). The obtained results revealed that in all cases there is a notable nonequivalency in the noncovalent intermolecular interactions of the two chlorine substituents of DCF and the radical intermediates with the solvent, which in turn may account for the discrepancy of their reactivity in different media. These computational results provide insight into the importance of halogen and hydrogen bonding throughout the progression of the photochemical conversion of DCF in solution.
Saravanan, Manoharan; Hur, Jang-Hyun; Arul, Narayanasamy; Ramesh, Mathan
2014-11-01
In the present investigation, the toxicity of most commonly detected pharmaceuticals in the aquatic environment namely clofibric acid (CA) and diclofenac (DCF) was investigated in an Indian major carp Cirrhinus mrigala. Fingerlings of C. mrigala were exposed to different concentrations (1, 10 and 100μgL(-1)) of CA and DCF for a period of 96h (short term) and 35 days (long term). The toxic effects of CA and DCF on thyroid hormones (THs) such as thyroid stimulating hormone (TSH), thyroxine (T4) and triiodothyronine (T3) levels were evaluated. During the short and long-term exposure period TSH level was found to be decreased at all concentrations of CA (except at the end of 14(th) day in 1 and 10μgL(-l) and 21(st) day in 1μgL(-l)) whereas in DCF exposed fish TSH level was found to be increased when compared to control groups. T4 level was found to be decreased at 1 and 100μgL(-l) of CA exposure at the end of 96h. However, T4 level was decreased at all concentrations of CA and DCF during long-term (35 days) exposure period. Fish exposed to all concentrations of CA and DCF had lower level of T3 in both the treatments. These results suggest that both CA and DCF drugs induced significant changes (P<0.01 and P<0.05) on thyroid hormonal levels of C. mrigala. The alterations of these hormonal levels can be used as potential biomarkers in monitoring of pharmaceutical drugs in aquatic organisms. Copyright © 2014 Elsevier B.V. All rights reserved.
Naddeo, V; Belgiorno, V; Kassinos, D; Mantzavinos, D; Meric, S
2010-01-01
The 20 kHz ultrasound-induced degradation of non-steroidal, anti-inflammatory drug diclofenac (DCF) was investigated. Several operating conditions, such as power density (25-100 W/L), substrate concentration (2.5-80 mg/L), initial solution pH (3.5-11), liquid bulk temperature and the type of sparging gas (air, oxygen, argon), were tested concerning their effect on DCF degradation (as assessed measuring absorbance at 276 nm) and hydroxyl radicals generation (as assessed measuring H(2)O(2) concentration). Sample mineralization (in terms of TOC and COD removal), aerobic biodegradability (as assessed by the BOD(5)/COD ratio) and ecotoxicity to Daphnia magna and Artemia salina were followed too. DCF conversion is enhanced at increased applied power densities and liquid bulk temperatures, acidic conditions and in the presence of dissolved air or oxygen. The reaction rate increases with increasing DCF concentration in the range 2.5-5mg/L but it remains constant in the range 40-80 mg/L, indicating different kinetic regimes (i.e. first and zero order, respectively). H(2)O(2) production rates in pure water are higher than those in DCF solutions, implying that decomposition basically proceeds through hydroxyl radical reactions. Mineralization is a slow process as reaction by-products are more stable than DCF to total oxidation; nonetheless, they are also more readily biodegradable. Toxicity to D. magna increases during the early stages of the reaction and then decreases progressively upon degradation of reaction by-products; nevertheless, complete toxicity elimination cannot be achieved at the conditions in question. Neither the original nor the treated DCF samples are toxic to A. salina.
Huang, Zhihe; Cao, Jianqiu; Guo, Shaofeng; Chen, Jinbao; Xu, Xiaojun
2014-04-01
We compare both analytically and numerically the distributed side-coupled cladding-pumped (DSCCP) fiber lasers and double cladding fiber (DCF) lasers. We show that, through optimization of the coupling and absorbing coefficients, the optical-to-optical efficiency of DSCCP fiber lasers can be made as high as that of DCF lasers. At the same time, DSCCP fiber lasers are better than the DCF lasers in terms of thermal management.
Accurate mask-based spatially regularized correlation filter for visual tracking
NASA Astrophysics Data System (ADS)
Gu, Xiaodong; Xu, Xinping
2017-01-01
Recently, discriminative correlation filter (DCF)-based trackers have achieved extremely successful results in many competitions and benchmarks. These methods utilize a periodic assumption of the training samples to efficiently learn a classifier. However, this assumption will produce unwanted boundary effects, which severely degrade the tracking performance. Correlation filters with limited boundaries and spatially regularized DCFs were proposed to reduce boundary effects. However, their methods used the fixed mask or predesigned weights function, respectively, which was unsuitable for large appearance variation. We propose an accurate mask-based spatially regularized correlation filter for visual tracking. Our augmented objective can reduce the boundary effect even in large appearance variation. In our algorithm, the masking matrix is converted into the regularized function that acts on the correlation filter in frequency domain, which makes the algorithm fast convergence. Our online tracking algorithm performs favorably against state-of-the-art trackers on OTB-2015 Benchmark in terms of efficiency, accuracy, and robustness.
Yen, Chih-Ta; Chen, Wen-Bin
2016-01-01
Chromatic dispersion from optical fiber is the most important problem that produces temporal skews and destroys the rectangular structure of code patterns in the spectra-amplitude-coding-based optical code-division multiple-access (SAC-OCDMA) system. Thus, the balance detection scheme does not work perfectly to cancel multiple access interference (MAI) and the system performance will be degraded. Orthogonal frequency-division multiplexing (OFDM) is the fastest developing technology in the academic and industrial fields of wireless transmission. In this study, the radio-over-fiber system is realized by integrating OFDM and OCDMA via polarization multiplexing scheme. The electronic dispersion compensation (EDC) equalizer element of OFDM integrated with the dispersion compensation fiber (DCF) is used in the proposed radio-over-fiber (RoF) system, which can efficiently suppress the chromatic dispersion influence in long-haul transmitted distance. A set of length differences for 10 km-long single-mode fiber (SMF) and 4 km-long DCF is to verify the compensation scheme by relative equalizer algorithms and constellation diagrams. In the simulation result, the proposed dispersion mechanism successfully compensates the dispersion from SMF and the system performance with dispersion equalizer is highly improved. PMID:27618042
Coupled Inertial Navigation and Flush Air Data Sensing Algorithm for Atmosphere Estimation
NASA Technical Reports Server (NTRS)
Karlgaard, Christopher D.; Kutty, Prasad; Schoenenberger, Mark
2016-01-01
This paper describes an algorithm for atmospheric state estimation based on a coupling between inertial navigation and flush air data-sensing pressure measurements. The navigation state is used in the atmospheric estimation algorithm along with the pressure measurements and a model of the surface pressure distribution to estimate the atmosphere using a nonlinear weighted least-squares algorithm. The approach uses a high-fidelity model of atmosphere stored in table-lookup form, along with simplified models propagated along the trajectory within the algorithm to aid the solution. Thus, the method is a reduced-order Kalman filter in which the inertial states are taken from the navigation solution and atmospheric states are estimated in the filter. The algorithm is applied to data from the Mars Science Laboratory entry, descent, and landing from August 2012. Reasonable estimates of the atmosphere are produced by the algorithm. The observability of winds along the trajectory are examined using an index based on the observability Gramian and the pressure measurement sensitivity matrix. The results indicate that bank reversals are responsible for adding information content. The algorithm is applied to the design of the pressure measurement system for the Mars 2020 mission. A linear covariance analysis is performed to assess estimator performance. The results indicate that the new estimator produces more precise estimates of atmospheric states than existing algorithms.
Analysis of Measurements for Solid State Lidar Development
NASA Technical Reports Server (NTRS)
Amzajerdian, Farzin
1996-01-01
A Detector Characterization Facility (DCF), capable of measuring 2-micron detection devices and evaluating heterodyne receivers, was developed at the Marshall Space Flight Center. The DCF is capable of providing all the necessary detection parameters for design, development, and calibration of coherent and incoherent solid state laser radar (lidar) systems. The coherent lidars in particular require an accurate knowledge of detector heterodyne quantum efficient, nonlinearity properties, and voltage-current relationship as a function of applied optical power. At present, no detector manufacturer provides these qualities or adequately characterizes their detectors for heterodyne detection operation. In addition, the detector characterization facility measures the detectors DC and AC quantum efficiencies noise equivalent power and frequency response up to several GHz. The DCF is also capable of evaluating various heterodyne detection schemes such as balanced detectors and fiber optic interferometers. The design and analyses of measurements for the DCF were preformed over the previous year and a detailed description of its design and capabilities was provided in the NASA report NAS8-38609/DO77. It should also be noted that the DCF design was further improved to allow for the characterization of diffractive andholographical optical elements and other critical components of coherent lidar systems.
NASA Astrophysics Data System (ADS)
Dar, Aasif Bashir; Jha, Rakesh Kumar
2017-03-01
Various dispersion compensation units are presented and evaluated in this paper. These dispersion compensation units include dispersion compensation fiber (DCF), DCF merged with fiber Bragg grating (FBG) (joint technique), and linear, square root, and cube root chirped tanh apodized FBG. For the performance evaluation 10 Gb/s NRZ transmission system over 100-km-long single-mode fiber is used. The three chirped FBGs are optimized individually to yield pulse width reduction percentage (PWRP) of 86.66, 79.96, 62.42% for linear, square root, and cube root, respectively. The DCF and Joint technique both provide a remarkable PWRP of 94.45 and 96.96%, respectively. The performance of optimized linear chirped tanh apodized FBG and DCF is compared for long-haul transmission system on the basis of quality factor of received signal. For both the systems maximum transmission distance is calculated such that quality factor is ≥ 6 at the receiver and result shows that performance of FBG is comparable to that of DCF with advantages of very low cost, small size and reduced nonlinear effects.
Yokota, Tomoya; Kato, Ken; Hamamoto, Yasuo; Tsubosa, Yasuhiro; Ogawa, Hirofumi; Ito, Yoshinori; Hara, Hiroki; Ura, Takashi; Kojima, Takashi; Chin, Keisho; Hironaka, Shuichi; Kii, Takayuki; Kojima, Yasushi; Akutsu, Yasunori; Matsushita, Hisayuki; Kawakami, Kentaro; Mori, Keita; Nagai, Yushi; Asami, Chika; Kitagawa, Yuko
2016-11-22
The standard treatment for locally advanced unresectable squamous cell carcinoma (SCC) of the oesophagus is chemoradiation with cisplatin and 5-fluorouracil (CF-RT). This multicentre phase II trial assessed the safety and efficacy of chemoselection with docetaxel plus cisplatin and 5-fluorouracil (DCF) induction chemotherapy (ICT) and subsequent conversion surgery (CS) for initially unresectable locally advanced SCC of the oesophagus. Patients with clinical T4 and/or unresectable supraclavicular lymph node metastasis were eligible. Treatment started with three cycles of DCF-ICT, followed by CS if resectable, or by CF-RT if unresectable. The resectability was re-evaluated at 30-40 Gy of CF-RT, followed by CS if resectable, or by completion of 60 Gy of CF-RT. If resectable after CF-RT, CS was performed. The primary end point was 1-year overall survival (OS). From April 2013 to July 2014, 48 patients were enrolled. CS was performed in 41.7% (n=20), including DCF-CS (n=18), DCF-CF-RT40Gy-CS (n=1), and DCF-CF-RT60Gy-CS (n=1). R0 resection was confirmed in 19 patients (39.6%). Grade ⩾3 postoperative complications included one event each of recurrent laryngeal nerve palsy, lung infection, wound infection, pulmonary fistula, and dysphagia; but no serious postoperative complications were observed in patients undergoing CS. Clinical complete response after CF-RT was confirmed in 4 patients (8.3%). The estimated 1-year OS was 67.9% and lower limit of 80% confidence interval was 59.7%. There was one treatment-related death in patient receiving DCF-CF-RT60Gy. Chemoselection with DCF-ICT followed by CS as a multidisciplinary treatment strategy showed promising signs of tolerability and efficacy in patients with locally advanced unresectable SCC of the oesophagus.
Yokota, Tomoya; Kato, Ken; Hamamoto, Yasuo; Tsubosa, Yasuhiro; Ogawa, Hirofumi; Ito, Yoshinori; Hara, Hiroki; Ura, Takashi; Kojima, Takashi; Chin, Keisho; Hironaka, Shuichi; Kii, Takayuki; Kojima, Yasushi; Akutsu, Yasunori; Matsushita, Hisayuki; Kawakami, Kentaro; Mori, Keita; Nagai, Yushi; Asami, Chika; Kitagawa, Yuko
2016-01-01
Background: The standard treatment for locally advanced unresectable squamous cell carcinoma (SCC) of the oesophagus is chemoradiation with cisplatin and 5-fluorouracil (CF-RT). This multicentre phase II trial assessed the safety and efficacy of chemoselection with docetaxel plus cisplatin and 5-fluorouracil (DCF) induction chemotherapy (ICT) and subsequent conversion surgery (CS) for initially unresectable locally advanced SCC of the oesophagus. Methods: Patients with clinical T4 and/or unresectable supraclavicular lymph node metastasis were eligible. Treatment started with three cycles of DCF-ICT, followed by CS if resectable, or by CF-RT if unresectable. The resectability was re-evaluated at 30–40 Gy of CF-RT, followed by CS if resectable, or by completion of 60 Gy of CF-RT. If resectable after CF-RT, CS was performed. The primary end point was 1-year overall survival (OS). Results: From April 2013 to July 2014, 48 patients were enrolled. CS was performed in 41.7% (n=20), including DCF-CS (n=18), DCF-CF-RT40Gy-CS (n=1), and DCF-CF-RT60Gy-CS (n=1). R0 resection was confirmed in 19 patients (39.6%). Grade ⩾3 postoperative complications included one event each of recurrent laryngeal nerve palsy, lung infection, wound infection, pulmonary fistula, and dysphagia; but no serious postoperative complications were observed in patients undergoing CS. Clinical complete response after CF-RT was confirmed in 4 patients (8.3%). The estimated 1-year OS was 67.9% and lower limit of 80% confidence interval was 59.7%. There was one treatment-related death in patient receiving DCF-CF-RT60Gy. Conclusions: Chemoselection with DCF-ICT followed by CS as a multidisciplinary treatment strategy showed promising signs of tolerability and efficacy in patients with locally advanced unresectable SCC of the oesophagus. PMID:27811857
A new topical formulation enhances relative diclofenac bioavailability in healthy male subjects
Brunner, Martin; Davies, David; Martin, Wolfgang; Leuratti, Chiara; Lackner, Edith; Müller, Markus
2011-01-01
AIMS To evaluate the relative plasma and tissue availability of diclofenac after repeated topical administration of a novel diclofenac acid-based delivery system under development (DCF100C). METHODS This was a single-centre, open-label, three-period, crossover clinical trial of five discrete diclofenac formulations. Test preparations comprised two concentrations (1.0% and 2.5%) of DCF100C, with and without menthol and eucalyptus oil (total daily doses of 5 mg and 12.5 mg). Voltaren® Emulgel® gel (1.0%) was the commercially available comparator (total daily dose of 40 mg). Topical application was performed onto the thigh of 20 male healthy subjects for 3 days. Applying a Youden square design, each drug was evaluated in 12 subjects, with each subject receiving three test preparations. Blood sampling and in vivo microdialysis in subcutaneous adipose and skeletal muscle tissues were performed for 10 h after additional final doses on the morning of day 4. RESULTS All four DCF100C formulations demonstrated a three- to fivefold, dose-dependent increase in systemic diclofenac availability compared with Voltaren® Emulgel® and were approximately 30–40 times more effective at facilitating diclofenac penetration through the skin, taking different dose levels into account. Tissue concentrations were low and highly variable. The 2.5% DCF100C formulation without sensory excipients reached the highest tissue concentrations. AUC(0,10 h) was 2.71 times greater than for Voltaren® Emulgel® (90% CI 99.27, 737.46%). Mild erythema at the application site was the most frequent adverse event associated with DCF100C. There were no local symptoms after treatment with the reference formulation. CONCLUSION DCF100C formulations were safe and facilitated greater diclofenac penetration through the skin compared with the commercial comparator. DCF100C represents a promising alternative to oral and topical diclofenac treatments that warrants further development. PMID:21241352
Shen, Duanwen; Bai, Mingfeng; Tang, Rui; Xu, Baogang; Ju, Xiaoming; Pestell, Richard G; Achilefu, Samuel
2013-01-01
Using a newly developed near-infrared (NIR) dye that fluoresces at two different wavelengths (dichromic fluorescence, DCF), we discovered a new fluorescent substrate for Akt, also known as protein kinase B, and a method to quantitatively report this enzyme's activity in real time. Upon insulin activation of cellular Akt, the enzyme multi-phosphorylated a single serine residue of a diserine DCF substrate in a time-dependent manner, culminating in monophospho- to triphospho-serine products. The NIR DCF probe was highly selective for the Akt1 isoform, which was demonstrated using Akt1 knockout cells derived from MMTV-ErbB2 transgenic mice. The DCF mechanism provides unparalleled potential to assess the stimulation, sustainability, and reversibility of Akt activation longitudinally. Importantly, NIR fluorescence provides a pathway to translate findings from cells to living organisms, a condition that could eventually facilitate the use of these probes in humans.
Robust object tacking based on self-adaptive search area
NASA Astrophysics Data System (ADS)
Dong, Taihang; Zhong, Sheng
2018-02-01
Discriminative correlation filter (DCF) based trackers have recently achieved excellent performance with great computational efficiency. However, DCF based trackers suffer boundary effects, which result in the unstable performance in challenging situations exhibiting fast motion. In this paper, we propose a novel method to mitigate this side-effect in DCF based trackers. We change the search area according to the prediction of target motion. When the object moves fast, broad search area could alleviate boundary effects and reserve the probability of locating object. When the object moves slowly, narrow search area could prevent effect of useless background information and improve computational efficiency to attain real-time performance. This strategy can impressively soothe boundary effects in situations exhibiting fast motion and motion blur, and it can be used in almost all DCF based trackers. The experiments on OTB benchmark show that the proposed framework improves the performance compared with the baseline trackers.
Saravanan, M; Ramesh, M
2013-09-01
Extensive use of pharmaceuticals in human and veterinary medicine and aquaculture practices pose a serious threat to aquatic organisms. In the present investigation, Cirrhinus mrigala an Indian major carp was exposed to different concentrations of clofibric acid (CA) and diclofenac (DCF) and certain biochemical and ionoregulatory responses were assessed under short and long term exposures. During short-term (96h) exposure period, plasma glucose and sodium (Na(+)) levels were increased at all concentrations (1, 10 and 100μgL(-1)) of CA and DCF treated fish. Plasma protein and chloride (Cl(-)) levels were found to be decreased at all concentrations of CA and DCF exposed fish comparatively to control groups. Meanwhile an increase in plasma potassium (K(+)) level was noted in fish exposed to CA treatments alone and in DCF treatments it was decreased. In long-term exposure (35d), plasma Na(+) and Cl(-) levels were found to be significantly increased at all concentration of CA and DCF. However, a biphasic trend was observed in plasma glucose, protein and K(+) levels. In both the treatments, a significant (P<0.01 and P<0.05) changes were observed in all parameters measured in fish exposed to different concentrations of CA and DCF. The results of the present investigation indicate that both the drugs caused significant changes in biochemical and ionoregulatory responses of fish at all concentrations. The alterations of these parameters can be useful in monitoring of pharmaceutical residues present in aquatic environment. Copyright © 2013 Elsevier Ltd. All rights reserved.
Gómez-Oliván, Leobardo Manuel; Galar-Martínez, Marcela; García-Medina, Sandra; Valdés-Alanís, Analleli; Islas-Flores, Hariz; Neri-Cruz, Nadia
2014-10-01
Nonsteroidal anti-inflammatory drugs (NSAIDs) are among the most commonly used pharmaceuticals in Mexico, but there is not proper regulation on the sale, use and disposal. These drugs can enter water bodies by diverse pathways, attaining significant concentrations and inducing damage on hydrobionts. To evaluate the oxidative stress and consequent damage to genetic material induced by DCF, IBP and NPX on Daphnia magna. The acute toxicity assays were performed to 48-h by nonsteroidal anti-inflammatory drugs evaluated. A sublethal assay were done after 48 h of exposure to DCF, IBP and NPX added to water with the concentration equivalent to the lowest observed adverse effect level (LOAEL), 9.7 mg/L for DCF, 2.9 mg/L for IBP and 0.017 mg/L for NPX. The DNA damage (comet assay) was evaluated at 12, 48 and 96 h. The oxidative biomarkers were evaluated: lipid peroxidation; protein carbonyl content; activity of the antioxidant enzymes superoxide dismutase, catalase and glutathione peroxidase. D. magna exposed to DCF, IBP and NPX showed a significant increase (p < 0.05) with respect to controls in LPX. PCC was increased in IBP exposure. SOD and CAT activity were increased by exposure to IBP and NPX. GPX shows a significant increase with respect to control in IBP and DCF exposure and significant decrease by NPX exposure. DNA damage was observed in 48 and 96 h. DCF, IBP and NPX were responsible of alterations in biochemical biomarkers evaluated and DNA damage.
1993-09-11
it has traditionally been presented. The following cash flows also trigger "IRR incalculable-NPV diverging from zero" in the DCF program : Projecta r 0... program disapproval or cancellation is inherent in defense analyses, thus the emphasis on "affordability,’ e.g., lower cost. A final difficulty with using...percent. (With the DCF program , it makes no difference which one you use.) See Table 7 and Figure 2. Project Year 0 Year I Year 2 NPV @ 10% 1IRRs’ DCF
On Curating Multimodal Sensory Data for Health and Wellness Platforms
Amin, Muhammad Bilal; Banos, Oresti; Khan, Wajahat Ali; Muhammad Bilal, Hafiz Syed; Gong, Jinhyuk; Bui, Dinh-Mao; Cho, Soung Ho; Hussain, Shujaat; Ali, Taqdir; Akhtar, Usman; Chung, Tae Choong; Lee, Sungyoung
2016-01-01
In recent years, the focus of healthcare and wellness technologies has shown a significant shift towards personal vital signs devices. The technology has evolved from smartphone-based wellness applications to fitness bands and smartwatches. The novelty of these devices is the accumulation of activity data as their users go about their daily life routine. However, these implementations are device specific and lack the ability to incorporate multimodal data sources. Data accumulated in their usage does not offer rich contextual information that is adequate for providing a holistic view of a user’s lifelog. As a result, making decisions and generating recommendations based on this data are single dimensional. In this paper, we present our Data Curation Framework (DCF) which is device independent and accumulates a user’s sensory data from multimodal data sources in real time. DCF curates the context of this accumulated data over the user’s lifelog. DCF provides rule-based anomaly detection over this context-rich lifelog in real time. To provide computation and persistence over the large volume of sensory data, DCF utilizes the distributed and ubiquitous environment of the cloud platform. DCF has been evaluated for its performance, correctness, ability to detect complex anomalies, and management support for a large volume of sensory data. PMID:27355955
FBG wavelength demodulation based on a radio frequency optical true time delay method.
Wang, Jin; Zhu, Wanshan; Ma, Chenyuan; Xu, Tong
2018-06-01
A new fiber Bragg grating (FBG) wavelength shift demodulation method based on optical true time delay microwave phase detection is proposed. We used a microwave photonic link (MPL) to transport a radio frequency (RF) signal over a dispersion compensation fiber (DCF). The wavelength shift of the FBG will cause the time delay change of the optical carrier that propagates in an optical fiber with chromatic dispersion, which will result in the variation of the RF signal phase. A long DCF was adopted to enlarge the RF signal phase variation. An IQ mixer was used to measure the RF phase variation of the RF signal propagating in the MPL, and the wavelength shift of the FBG can be obtained by the measured RF signal phase variation. The experimental results showed that the wavelength shift measurement resolution is 2 pm when the group velocity dispersion of the DCF is 79.5 ps/nm and the frequency of the RF signal is 18 GHz. The demodulation time is as short as 0.1 ms. The measurement resolution can be improved simply by using a higher frequency of the RF signal and a longer DCF or larger chromatic dispersion value of the DCF.
Lonappan, Linson; Pulicharla, Rama; Rouissi, Tarek; Brar, Satinder K; Verma, Mausam; Surampalli, Rao Y; Valero, José R
2016-02-12
Diclofenac (DCF), a prevalent non-steroidal anti-inflammatory drug (NSAID) is often detected in wastewater and surface water. Analysis of the pharmaceuticals in complex matrices is often laden with challenges. In this study a reliable, rapid and sensitive method based on laser diode thermal desorption/atmospheric pressure chemical ionization (LDTD/APCI) coupled with tandem mass spectrometry (MS/MS) has been developed for the quantification of DCF in wastewater and wastewater sludge. An established conventional LC-ESI-MS/MS (liquid chromatography-electrospray ionization-tandem mass spectrometry) method was compared with LDTD-APCI-MS/MS approach. The newly developed LDTD-APCI-MS/MS method reduced the analysis time to 12s in lieu of 12 min for LC-ESI-MS/MS method. The method detection limits for LDTD-APCI-MS/MS method were found to be 270 ng L(-1) (LOD) and 1000 ng L(-1) (LOQ). Furthermore, two extraction procedures, ultrasonic assisted extraction (USE) and accelerated solvent extraction (ASE) for the extraction of DCF from wastewater sludge were compared and ASE with 95.6 ± 7% recovery was effective over USE with 86 ± 4% recovery. The fate and partitioning of DCF in wastewater (WW) and wastewater sludge (WWS) in wastewater treatment plant was also monitored at various stages of treatment in Quebec Urban community wastewater treatment plant. DCF exhibited affinity towards WW than WWS with a presence about 60% of DCF in WW in contrary with theoretical prediction (LogKow=4.51). Copyright © 2016 Elsevier B.V. All rights reserved.
Management of pharmaceutical substances in the environment: Lithuanian case study.
Baranauskaitė-Fedorova, Inga; Dvarionienė, Jolanta; Nikiforov, Vladimir A
2016-09-01
Investigation on the sources, discharges and related risks for the environment of the pharmaceutical substance (PhS) diclofenac (DCF) was performed in Lithuania, a country of the Baltic Sea region, for the first time. The investigation only refers to DCF as a PhS for human use; emissions from animal husbandry were not considered. In the first stage of the research, the main sources and pathways of DCF via substance flow analysis were identified within the country. During the second stage, DCF flows along the wastewater treatment plants (WWTPs) in two different cities were measured in order to assess the current levels of pharmaceutical residues in the environment. Furthermore, environmental risk assessment was carried out by taking into account the parameters of consumption data and elimination rate in WWTPs. Then, the assessment of different technical and managerial removal approaches was accomplished in an environmental management model of wastewater containing PhS, based on the framework of environmental systems theory.
Improved First Pass Spiral Myocardial Perfusion Imaging with Variable Density Trajectories
Salerno, Michael; Sica, Christopher; Kramer, Christopher M.; Meyer, Craig H.
2013-01-01
Purpose To develop and evaluate variable-density (VD) spiral first-pass perfusion pulse sequences for improved efficiency and off-resonance performance and to demonstrate the utility of an apodizing density compensation function (DCF) to improve SNR and reduce dark-rim artifact caused by cardiac motion and Gibbs Ringing. Methods Three variable density spiral trajectories were designed, simulated, and evaluated in 18 normal subjects, and in 8 patients with cardiac pathology on a 1.5T scanner. Results By utilizing a density compensation function (DCF) which intentionally apodizes the k-space data, the side-lobe amplitude of the theoretical PSF is reduced by 68%, with only a 13% increase in the FWHM of the main-lobe as compared to the same data corrected with a conventional VD DCF, and has an 8% higher resolution than a uniform density spiral with the same number of interleaves and readout duration. Furthermore, this strategy results in a greater than 60% increase in measured SNR as compared to the same VD spiral data corrected with a conventional DCF (p<0.01). Perfusion defects could be clearly visualized with minimal off-resonance and dark-rim artifacts. Conclusion VD spiral pulse sequences using an apodized DCF produce high-quality first-pass perfusion images with minimal dark-rim and off-resonance artifacts, high SNR and CNR and good delineation of resting perfusion abnormalities. PMID:23280884
Diclofenac removal from water with ozone and activated carbon.
Beltrán, Fernando J; Pocostales, Pablo; Alvarez, Pedro; Oropesa, Ana
2009-04-30
Diclofenac (DCF) has been treated in water with ozone in the presence of various activated carbons. Activated carbon-free ozonation or single ozonation leads to a complete degradation of DCF in less than 15 min while in the presence of activated carbons higher degradation rates of TOC and DCF are noticeably achieved. Among the activated carbons used, P110 Hydraffin was found the most suitable for the catalytic ozonation of DCF. The influence of pH was also investigated. In the case of the single ozonation the increasing pH slightly increases the TOC removal rate. This effect, however, was not so clear in the presence of activated carbons where the influence of the adsorption process must be considered. Ecotoxicity experiments were performed, pointing out that single ozonation reduces the toxicity of the contaminated water but catalytic ozonation improved those results. As far as kinetics is concerned, DCF is removed with ozone in a fast kinetic regime and activated carbon merely acts as a simple adsorbent. However, for TOC removal the ozonation kinetic regime becomes slow. In the absence of the adsorbent, the apparent rate constant of the mineralization process was determined at different pH values. On the other hand, determination of the rate constant of the catalytic reaction over the activated carbon was not possible due to the effect of mass transfer resistances that controlled the process rate at the conditions investigated.
Lu, Xian; Shao, Yisheng; Gao, Naiyun; Chen, Juxiang; Zhang, Yansen; Xiang, Huiming; Guo, Youluo
2017-07-01
Diclofenac (DCF) is the frequently detected non-steroidal pharmaceuticals in the aquatic environment. In this study, the degradation of DCF was evaluated by UV-254nm activated persulfate (UV/PS). The degradation of DCF followed the pseudo first-order kinetics pattern. The degradation rate constant (k obs ) was accelerated by UV/PS compared to UV alone and PS alone. Increasing the initial PS dosage or solution pH significantly enhanced the degradation efficiency. Presence of various natural water constituents had different effects on DCF degradation, with an enhancement or inhibition in the presence of inorganic anions (HCO 3 - or Cl - ) and a significant inhibition in the presence of NOM. In addition, preliminary degradation mechanisms and major products were elucidated using LC-MS/MS. Hydroxylation, decarbonylation, ring-opening and cyclation reaction involving the attack of SO 4 • - or other substances, were the main degradation mechanism. TOC analyzer and Microtox bioassay were employed to evaluate the mineralization and cytotoxicity of solutions treated by UV/PS at different times, respectively. Limited elimination of TOC (32%) was observed during the mineralization of DCF. More toxic degradation products and their related intermediate species were formed, and the UV/PS process was suitable for removing the toxicity. Of note, longer degradation time may be considered for the final toxicity removal. Copyright © 2017. Published by Elsevier Inc.
Multi-channel distributed coordinated function over single radio in wireless sensor networks.
Campbell, Carlene E-A; Loo, Kok-Keong Jonathan; Gemikonakli, Orhan; Khan, Shafiullah; Singh, Dhananjay
2011-01-01
Multi-channel assignments are becoming the solution of choice to improve performance in single radio for wireless networks. Multi-channel allows wireless networks to assign different channels to different nodes in real-time transmission. In this paper, we propose a new approach, Multi-channel Distributed Coordinated Function (MC-DCF) which takes advantage of multi-channel assignment. The backoff algorithm of the IEEE 802.11 distributed coordination function (DCF) was modified to invoke channel switching, based on threshold criteria in order to improve the overall throughput for wireless sensor networks (WSNs) over 802.11 networks. We presented simulation experiments in order to investigate the characteristics of multi-channel communication in wireless sensor networks using an NS2 platform. Nodes only use a single radio and perform channel switching only after specified threshold is reached. Single radio can only work on one channel at any given time. All nodes initiate constant bit rate streams towards the receiving nodes. In this work, we studied the impact of non-overlapping channels in the 2.4 frequency band on: constant bit rate (CBR) streams, node density, source nodes sending data directly to sink and signal strength by varying distances between the sensor nodes and operating frequencies of the radios with different data rates. We showed that multi-channel enhancement using our proposed algorithm provides significant improvement in terms of throughput, packet delivery ratio and delay. This technique can be considered for WSNs future use in 802.11 networks especially when the IEEE 802.11n becomes popular thereby may prevent the 802.15.4 network from operating effectively in the 2.4 GHz frequency band.
Multi-Channel Distributed Coordinated Function over Single Radio in Wireless Sensor Networks
Campbell, Carlene E.-A.; Loo, Kok-Keong (Jonathan); Gemikonakli, Orhan; Khan, Shafiullah; Singh, Dhananjay
2011-01-01
Multi-channel assignments are becoming the solution of choice to improve performance in single radio for wireless networks. Multi-channel allows wireless networks to assign different channels to different nodes in real-time transmission. In this paper, we propose a new approach, Multi-channel Distributed Coordinated Function (MC-DCF) which takes advantage of multi-channel assignment. The backoff algorithm of the IEEE 802.11 distributed coordination function (DCF) was modified to invoke channel switching, based on threshold criteria in order to improve the overall throughput for wireless sensor networks (WSNs) over 802.11 networks. We presented simulation experiments in order to investigate the characteristics of multi-channel communication in wireless sensor networks using an NS2 platform. Nodes only use a single radio and perform channel switching only after specified threshold is reached. Single radio can only work on one channel at any given time. All nodes initiate constant bit rate streams towards the receiving nodes. In this work, we studied the impact of non-overlapping channels in the 2.4 frequency band on: constant bit rate (CBR) streams, node density, source nodes sending data directly to sink and signal strength by varying distances between the sensor nodes and operating frequencies of the radios with different data rates. We showed that multi-channel enhancement using our proposed algorithm provides significant improvement in terms of throughput, packet delivery ratio and delay. This technique can be considered for WSNs future use in 802.11 networks especially when the IEEE 802.11n becomes popular thereby may prevent the 802.15.4 network from operating effectively in the 2.4 GHz frequency band. PMID:22346614
NASA Astrophysics Data System (ADS)
Barraza Bernadas, V.; Grings, F.; Roitberg, E.; Perna, P.; Karszenbaum, H.
2017-12-01
The Dry Chaco region (DCF) has the highest absolute deforestation rates of all Argentinian forests. The most recent report indicates a current deforestation rate of 200,000 Ha year-1. In order to better monitor this process, DCF was chosen to implement an early warning program for illegal deforestation. Although the area is intensively studied using medium resolution imagery (Landsat), the products obtained have a yearly pace and therefore unsuited for an early warning program. In this paper, we evaluated the performance of an online Bayesian change-point detection algorithm for MODIS Enhanced Vegetation Index (EVI) and Land Surface Temperature (LST) datasets. The goal was to to monitor the abrupt changes in vegetation dynamics associated with deforestation events. We tested this model by simulating 16-day EVI and 8-day LST time series with varying amounts of seasonality, noise, length of the time series and by adding abrupt changes with different magnitudes. This model was then tested on real satellite time series available through the Google Earth Engine, over a pilot area in DCF, where deforestation was common in the 2004-2016 period. A comparison with yearly benchmark products based on Landsat images is also presented (REDAF dataset). The results shows the advantages of using an automatic model to detect a changepoint in the time series than using only visual inspection techniques. Simulating time series with varying amounts of seasonality and noise, and by adding abrupt changes at different times and magnitudes, revealed that this model is robust against noise, and is not influenced by changes in amplitude of the seasonal component. Furthermore, the results compared favorably with REDAF dataset (near 65% of agreement). These results show the potential to combine LST and EVI to identify deforestation events. This work is being developed within the frame of the national Forest Law for the protection and sustainable development of Native Forest in Argentina in agreement with international legislation (REDD+).
Real-time control of combined surface water quantity and quality: polder flushing.
Xu, M; van Overloop, P J; van de Giesen, N C; Stelling, G S
2010-01-01
In open water systems, keeping both water depths and water quality at specified values is critical for maintaining a 'healthy' water system. Many systems still require manual operation, at least for water quality management. When applying real-time control, both quantity and quality standards need to be met. In this paper, an artificial polder flushing case is studied. Model Predictive Control (MPC) is developed to control the system. In addition to MPC, a 'forward estimation' procedure is used to acquire water quality predictions for the simplified model used in MPC optimization. In order to illustrate the advantages of MPC, classical control [Proportional-Integral control (PI)] has been developed for comparison in the test case. The results show that both algorithms are able to control the polder flushing process, but MPC is more efficient in functionality and control flexibility.
Mohammed, Nazmi A; Solaiman, Mohammad; Aly, Moustafa H
2014-10-10
In this work, various dispersion compensation methods are designed and evaluated to search for a cost-effective technique with remarkable dispersion compensation and a good pulse shape. The techniques consist of different chirp functions applied to a tanh fiber Bragg grating (FBG), a dispersion compensation fiber (DCF), and a DCF merged with an optimized linearly chirped tanh FBG (joint technique). The techniques are evaluated using a standard 10 Gb/s optical link over a 100 km long haul. The linear chirp function is the most appropriate choice of chirping function, with a pulse width reduction percentage (PWRP) of 75.15%, lower price, and poor pulse shape. The DCF yields an enhanced PWRP of 93.34% with a better pulse quality; however, it is the most costly of the evaluated techniques. Finally, the joint technique achieved the optimum PWRP (96.36%) among all the evaluated techniques and exhibited a remarkable pulse shape; it is less costly than the DCF, but more expensive than the chirped tanh FBG.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hay, Tristan R.; Rishel, Jeremy P.
2013-09-30
The Air Pollutant Graphical Environmental Monitoring System (APGEMS) is used by the Hanford Emergency Operation Center (EOC) to provide refined plume modeling of releases involving radionuclides. The dose conversion factors (DCFs) used by APGEMS to convert air concentration to dose are stored in a file called HUDUFACT.dat; the DCFs are based primarily on ICRP 30 compiled in the late 1980’s. This report updates the DCFs using more recent values reported in the Environmental Protection Agencies (EPAs) Federal Guidance Report (FGR) 12 and 13. FGR 12 provides external exposure (air submersion) DCFs for radionuclides in air; FGR 13 provides DCFs formore » radionuclides from inhalation. DCFs were updated for only those radionuclides listed in the original HUDUFACT.dat file. Since FGR 13 provides inhalation dose conversion factors as a function of age, revised DCF files were created for APGEMS for each age group. The “adult” DCF file is the most relevant to compare to the original DCF file being used in APGEMS; these DCF values are compared in this report.« less
Rautengarten, Carsten; Ebert, Berit; Ouellet, Mario; Nafisi, Majse; Baidoo, Edward E.K.; Benke, Peter; Stranne, Maria; Mukhopadhyay, Aindrila; Keasling, Jay D.; Sakuragi, Yumiko; Scheller, Henrik Vibe
2012-01-01
The cuticle is a complex aliphatic polymeric layer connected to the cell wall and covers surfaces of all aerial plant organs. The cuticle prevents nonstomatal water loss, regulates gas exchange, and acts as a barrier against pathogen infection. The cuticle is synthesized by epidermal cells and predominantly consists of an aliphatic polymer matrix (cutin) and intracuticular and epicuticular waxes. Cutin monomers are primarily C16 and C18 unsubstituted, ω-hydroxy, and α,ω-dicarboxylic fatty acids. Phenolics such as ferulate and p-coumarate esters also contribute to a minor extent to the cutin polymer. Here, we present the characterization of a novel acyl-coenzyme A (CoA)-dependent acyl-transferase that is encoded by a gene designated Deficient in Cutin Ferulate (DCF). The DCF protein is responsible for the feruloylation of ω-hydroxy fatty acids incorporated into the cutin polymer of aerial Arabidopsis (Arabidopsis thaliana) organs. The enzyme specifically transfers hydroxycinnamic acids using ω-hydroxy fatty acids as acyl acceptors and hydroxycinnamoyl-CoAs, preferentially feruloyl-CoA and sinapoyl-CoA, as acyl donors in vitro. Arabidopsis mutant lines carrying DCF loss-of-function alleles are devoid of rosette leaf cutin ferulate and exhibit a 50% reduction in ferulic acid content in stem insoluble residues. DCF is specifically expressed in the epidermis throughout all green Arabidopsis organs. The DCF protein localizes to the cytosol, suggesting that the feruloylation of cutin monomers takes place in the cytoplasm. PMID:22158675
Rautengarten, Carsten; Ebert, Berit; Ouellet, Mario; Nafisi, Majse; Baidoo, Edward E K; Benke, Peter; Stranne, Maria; Mukhopadhyay, Aindrila; Keasling, Jay D; Sakuragi, Yumiko; Scheller, Henrik Vibe
2012-02-01
The cuticle is a complex aliphatic polymeric layer connected to the cell wall and covers surfaces of all aerial plant organs. The cuticle prevents nonstomatal water loss, regulates gas exchange, and acts as a barrier against pathogen infection. The cuticle is synthesized by epidermal cells and predominantly consists of an aliphatic polymer matrix (cutin) and intracuticular and epicuticular waxes. Cutin monomers are primarily C(16) and C(18) unsubstituted, ω-hydroxy, and α,ω-dicarboxylic fatty acids. Phenolics such as ferulate and p-coumarate esters also contribute to a minor extent to the cutin polymer. Here, we present the characterization of a novel acyl-coenzyme A (CoA)-dependent acyl-transferase that is encoded by a gene designated Deficient in Cutin Ferulate (DCF). The DCF protein is responsible for the feruloylation of ω-hydroxy fatty acids incorporated into the cutin polymer of aerial Arabidopsis (Arabidopsis thaliana) organs. The enzyme specifically transfers hydroxycinnamic acids using ω-hydroxy fatty acids as acyl acceptors and hydroxycinnamoyl-CoAs, preferentially feruloyl-CoA and sinapoyl-CoA, as acyl donors in vitro. Arabidopsis mutant lines carrying DCF loss-of-function alleles are devoid of rosette leaf cutin ferulate and exhibit a 50% reduction in ferulic acid content in stem insoluble residues. DCF is specifically expressed in the epidermis throughout all green Arabidopsis organs. The DCF protein localizes to the cytosol, suggesting that the feruloylation of cutin monomers takes place in the cytoplasm.
Improved first-pass spiral myocardial perfusion imaging with variable density trajectories.
Salerno, Michael; Sica, Christopher; Kramer, Christopher M; Meyer, Craig H
2013-11-01
To develop and evaluate variable-density spiral first-pass perfusion pulse sequences for improved efficiency and off-resonance performance and to demonstrate the utility of an apodizing density compensation function (DCF) to improve signal-to-noise ratio (SNR) and reduce dark-rim artifact caused by cardiac motion and Gibbs Ringing. Three variable density spiral trajectories were designed, simulated, and evaluated in 18 normal subjects, and in eight patients with cardiac pathology on a 1.5T scanner. By using a DCF, which intentionally apodizes the k-space data, the sidelobe amplitude of the theoretical point spread function (PSF) is reduced by 68%, with only a 13% increase in the full-width at half-maximum of the main-lobe when compared with the same data corrected with a conventional variable-density DCF, and has an 8% higher resolution than a uniform density spiral with the same number of interleaves and readout duration. Furthermore, this strategy results in a greater than 60% increase in measured SNR when compared with the same variable-density spiral data corrected with a conventional DCF (P < 0.01). Perfusion defects could be clearly visualized with minimal off-resonance and dark-rim artifacts. Variable-density spiral pulse sequences using an apodized DCF produce high-quality first-pass perfusion images with minimal dark-rim and off-resonance artifacts, high SNR and contrast-to-noise ratio, and good delineation of resting perfusion abnormalities. Copyright © 2012 Wiley Periodicals, Inc.
The X-43A Flush Airdata Sensing System Flight Test Results
NASA Technical Reports Server (NTRS)
Baumann, Ethan; Pahle, Joseph W.; Davis, Mark; White, John Terry
2008-01-01
The National Aeronautics and Space Administration (NASA) has flight-tested a flush airdata sensing (FADS) system on the Hyper-X Research Vehicle (X-43A) at hypersonic speeds during the course of two successful flights. For this series of tests, the FADS system was calibrated to operate between Mach 3 and Mach 8, and flight test data was collected between Mach 1 and Mach 10. The FADS system acquired pressure data from surface-mounted ports and generated a real-time angle-of-attack (alpha) estimate on board the X-43A. The collected data were primarily intended to evaluate the FADS system performance, and the estimated alpha was used by the flight control algorithms on the X-43A for only a portion of the first successful flight. This paper provides an overview of the FADS system and alpha estimation algorithms, presents the in-flight alpha estimation algorithm performance, and provides comparisons to wind tunnel results and theory. Results indicate that the FADS system adequately estimated the alpha of the vehicle during the hypersonic portions of the two flights.
Coupled Inertial Navigation and Flush Air Data Sensing Algorithm for Atmosphere Estimation
NASA Technical Reports Server (NTRS)
Karlgaard, Christopher D.; Kutty, Prasad; Schoenenberger, Mark
2015-01-01
This paper describes an algorithm for atmospheric state estimation that is based on a coupling between inertial navigation and flush air data sensing pressure measurements. In this approach, the full navigation state is used in the atmospheric estimation algorithm along with the pressure measurements and a model of the surface pressure distribution to directly estimate atmospheric winds and density using a nonlinear weighted least-squares algorithm. The approach uses a high fidelity model of atmosphere stored in table-look-up form, along with simplified models of that are propagated along the trajectory within the algorithm to provide prior estimates and covariances to aid the air data state solution. Thus, the method is essentially a reduced-order Kalman filter in which the inertial states are taken from the navigation solution and atmospheric states are estimated in the filter. The algorithm is applied to data from the Mars Science Laboratory entry, descent, and landing from August 2012. Reasonable estimates of the atmosphere and winds are produced by the algorithm. The observability of winds along the trajectory are examined using an index based on the discrete-time observability Gramian and the pressure measurement sensitivity matrix. The results indicate that bank reversals are responsible for adding information content to the system. The algorithm is then applied to the design of the pressure measurement system for the Mars 2020 mission. The pressure port layout is optimized to maximize the observability of atmospheric states along the trajectory. Linear covariance analysis is performed to assess estimator performance for a given pressure measurement uncertainty. The results indicate that the new tightly-coupled estimator can produce enhanced estimates of atmospheric states when compared with existing algorithms.
Jiang, Cong; Hu, Haidong; Ma, Haijun; Gao, Xingsheng; Ren, Hongqiang
2017-01-01
This study covers three widely detected non-steroidal anti-inflammatory pharmaceuticals (NSAIDs), diclofenac (DCF), ibuprofen (IBP) and naproxen (NPX), as NSAIDs pollutants. The objective is to evaluate the impact of NSAIDs at their environmental concentrations on microbial community assembly and activity. The exposure experiments were conducted under three conditions (5 μg L-1 DCF, 5 μg L-1 DCF+5 μg L-1 IBP and 5 μg L-1 DCF+5 μg L-1 IBP+ 5 μg L-1 NPX) in sequencing batch reactors (SBRs) for 130 days. Removals of COD and NH4+-N were not affected but total nitrogen (TN) removal decreased. IBP and NPX had the high removal efficiencies (79.96% to 85.64%), whereas DCF was more persistent (57.24% to 64.12%). In addition, the decreased removals of TN remained the same under the three conditions (p > 0.05). The results of oxidizing enzyme activities, live cell percentages and extracellular polymeric substances (EPS) indicated that NSAIDs damaged the cell walls or microorganisms and the mixtures of the three NSAIDs increased the toxicity. The increased Shannon-Wiener diversity index suggested that bacterial diversity was increased with the addition of selected NSAIDs. Bacterial ribosomal RNA small subunit (16S) gene sequencing results indicated that Actinobacteria and Bacteroidetes were enriched, while Micropruina and Nakamurella decreased with the addition of NSAIDs. The enrichment of Actinobacteria and Bacteroidetes indicated that both of them might have the ability to degrade NSAIDs and thereby could adapt well with the presence of NSAIDs. PMID:28640897
Jiang, Cong; Geng, Jinju; Hu, Haidong; Ma, Haijun; Gao, Xingsheng; Ren, Hongqiang
2017-01-01
This study covers three widely detected non-steroidal anti-inflammatory pharmaceuticals (NSAIDs), diclofenac (DCF), ibuprofen (IBP) and naproxen (NPX), as NSAIDs pollutants. The objective is to evaluate the impact of NSAIDs at their environmental concentrations on microbial community assembly and activity. The exposure experiments were conducted under three conditions (5 μg L-1 DCF, 5 μg L-1 DCF+5 μg L-1 IBP and 5 μg L-1 DCF+5 μg L-1 IBP+ 5 μg L-1 NPX) in sequencing batch reactors (SBRs) for 130 days. Removals of COD and NH4+-N were not affected but total nitrogen (TN) removal decreased. IBP and NPX had the high removal efficiencies (79.96% to 85.64%), whereas DCF was more persistent (57.24% to 64.12%). In addition, the decreased removals of TN remained the same under the three conditions (p > 0.05). The results of oxidizing enzyme activities, live cell percentages and extracellular polymeric substances (EPS) indicated that NSAIDs damaged the cell walls or microorganisms and the mixtures of the three NSAIDs increased the toxicity. The increased Shannon-Wiener diversity index suggested that bacterial diversity was increased with the addition of selected NSAIDs. Bacterial ribosomal RNA small subunit (16S) gene sequencing results indicated that Actinobacteria and Bacteroidetes were enriched, while Micropruina and Nakamurella decreased with the addition of NSAIDs. The enrichment of Actinobacteria and Bacteroidetes indicated that both of them might have the ability to degrade NSAIDs and thereby could adapt well with the presence of NSAIDs.
Effect of elastic constants of liquid crystals in their electro-optical properties
NASA Astrophysics Data System (ADS)
Parang, Z.; Ghaffary, T.; Gharahbeigi, M. M.
Recently following the success of the density functional theory (DFT) in obtaining the structure and thermodynamics of homogeneous and inhomogeneous classical systems such as simple fluids, dipolar fluid and binary hard spheres, this theory was also applied to obtain the density profile of a molecular fluid in between hard planar walls by Kalpaxis and Rickayzen. In the theory of molecular fluids, the direct correlation function (DCF) can be used to calculate the equation of state, free energy, phase transition, elastic constants, etc. It is well known that the hard core molecular models play an important role in understanding complex liquids such as liquid crystals. In this paper, a classical fluid of nonspherical molecules is studied. The required homogeneous (DCF) is obtained by solving Orenstein-Zernike (OZ) integral equation numerically. Some of the molecules in the liquid crystals have a sphere shape and this kind of molecular fluid is considered here. The DCF sphere of the molecular fluid is calculated and it will be shown that the results are in good agreement with the pervious works and the results of computer simulation. Finally the electro-optical properties of ellipsoid liquid crystal using DCF of these molecules are calculated.
Clinical effects of deep cervical flexor muscle activation in patients with chronic neck pain
Kim, Jin Young; Kwag, Kwang Il
2016-01-01
[Purpose] The purpose of this study was to investigate clinical effects of deep cervical flexor (DCF) muscles exercise on pain, Neck Disability Index (NDI), and neck and shoulder postures in patients with chronic neck pain. [Subjects and Methods] Twenty-eight patients with chronic neck pain were randomly assigned into either the general strengthening exercise (GSE) group or the DCF activation group as control and experimental groups, respectively. All exercises were performed three times per week over 4 weeks. NDI and numeric rating scale (NRS) score for pain were determined and radiological assessment of neck-shoulder postures (head tilt angle [HTA], neck flexion angle [NFA], and forward shoulder angle [FSA]) was performed before (baseline), 4 weeks after, and 8 weeks after exercise in order to directly compare the exercise effects between the groups. [Results] In the DCF group, the NDI, NRS score, and neck-shoulder postures (analyzed by uisng HTA, NFA, and FSA) were significantly improved. [Conclusion] DCF activation exercise was effective to alleviate pain, recover functions, and correct forward head posture in the patients with neck pain. Hence, it might be recommended in the rehabilitation of patients with chronic neck pain. PMID:26957772
Kwak, Dong-Heui; Kim, Mi-Sug
2015-01-01
The effect of chemical coagulation and biological auto-flocculation relative to zeta potential was examined to compare flotation and sedimentation separation processes for algae harvesting. Experiments revealed that microalgae separation is related to auto-flocculation of Anabaena spp. and requires chemical coagulation for the whole period of microalgae cultivation. In addition, microalgae separation characteristics which are associated with surfactants demonstrated optimal microalgae cultivation time and separation efficiency of dissolved CO2 flotation (DCF) as an alternative to dissolved air flotation (DAF). Microalgae were significantly separated in response to anionic surfactant rather than cationic surfactant as a function of bubble size and zeta potential. DAF and DCF both showed slightly efficient flotation; however, application of anionic surfactant was required when using DCF.
Three-Axis Attitude Estimation With a High-Bandwidth Angular Rate Sensor
NASA Technical Reports Server (NTRS)
Bayard, David S.; Green, Joseph J.
2013-01-01
A continuing challenge for modern instrument pointing control systems is to meet the increasingly stringent pointing performance requirements imposed by emerging advanced scientific, defense, and civilian payloads. Instruments such as adaptive optics telescopes, space interferometers, and optical communications make unprecedented demands on precision pointing capabilities. A cost-effective method was developed for increasing the pointing performance for this class of NASA applications. The solution was to develop an attitude estimator that fuses star tracker and gyro measurements with a high-bandwidth angular rotation sensor (ARS). An ARS is a rate sensor whose bandwidth extends well beyond that of the gyro, typically up to 1,000 Hz or higher. The most promising ARS sensor technology is based on a magnetohydrodynamic concept, and has recently become available commercially. The key idea is that the sensor fusion of the star tracker, gyro, and ARS provides a high-bandwidth attitude estimate suitable for supporting pointing control with a fast-steering mirror or other type of tip/tilt correction for increased performance. The ARS is relatively inexpensive and can be bolted directly next to the gyro and star tracker on the spacecraft bus. The high-bandwidth attitude estimator fuses an ARS sensor with a standard three-axis suite comprised of a gyro and star tracker. The estimation architecture is based on a dual-complementary filter (DCF) structure. The DCF takes a frequency- weighted combination of the sensors such that each sensor is most heavily weighted in a frequency region where it has the lowest noise. An important property of the DCF is that it avoids the need to model disturbance torques in the filter mechanization. This is important because the disturbance torques are generally not known in applications. This property represents an advantage over the prior art because it overcomes a weakness of the Kalman filter that arises when fusing more than one rate measurement. An additional advantage over prior art is that, computationally, the DCF requires significantly fewer real-time calculations than a Kalman filter formulation. There are essentially two reasons for this: the DCF state is not augmented with angular rate, and measurement updates occur at the slower gyro rate instead of the faster ARS sampling rate. Finally, the DCF has a simple and compelling architecture. The DCF is exactly equivalent to flying two identical attitude observers, one at low rate and one at high rate. These attitude observers are exactly of the form currently flown on typical three-axis spacecraft.
Serron, S C; Dwivedi, N; Backes, W L
2000-05-01
Small aromatic hydrocarbons cause changes in oxidative metabolism by modulating the levels of cytochrome P450 enzymes, with the changes in these enzymes being responsible for qualitative changes in aromatic hydrocarbon metabolism. The goal of this study was to determine if exposure to the small alkylbenzene ethylbenzene (EB) leads to an increase in hepatic free radical production. Male F344 rats were treated with ip injections of EB (10 mmol/kg) and compared to corn oil controls. Hepatic free radical production was examined by measuring the conversion of 2',7'-dichlorofluorescin diacetate (DCFH-DA) to its fluorescent product 2',7'-dichlorofluorescein (DCF). A significant elevation of fluorescent DCF production was observed after treatment with EB, despite the lack of effect on overall cytochrome P450 levels. This process was shown to be inhibitable by metyrapone, an inhibitor of P450. DCF production was also inhibited by catalase, suggesting that hydrogen peroxide (H(2)O(2)) is one of the reactive oxygen intermediates involved in EB-mediated reactive oxygen species (ROS) formation. Interestingly, superoxide dismutase (SOD) did not inhibit DCF production in corn oil-treated rats but was an effective inhibitor in the EB-treated groups. In an effort to determine if the increase in ROS production was related to changes in specific P450 enzymes, DCF production was measured in the presence of anti-CYP2B, anti-CYP2C11, anti-CYP2E1, and anti-CYP3A2 inhibitory antibodies. Anti-CYP2B antibodies inhibited DCF production in EB-treated, but not corn oil groups, which is consistent with the low constitutive levels of this enzyme and its induction by EB. The data also demonstrate that CYP2B contributes to ROS production. Anti-CYP2C11 did not influence DCF production in either group. ROS formation in corn oil-treated rats as well as in ethylbenzene-treated rats was also inhibited with antibodies to anti-CYP2E1 and anti-CYP3A2. These results suggest that CYP2C11 does not appear to influence free radical production and that the increase in free radical production in EB treated rats is consistent with the EB-mediated elevation of CYP2B, CYP 2E1, and CYP3A2. Such alterations in free radical generation in response to hydrocarbon treatment may contribute to the toxicity of these compounds. Copyright 2000 Academic Press.
Watch for pitfalls of discounted cash flow techniques.
Chow, C W; McNamee, A H
1991-04-01
Discounted cash flow (DCF) techniques can enhance the effectiveness of a healthcare organization's capital budgeting decisions. But a financial manager unaware of common misapplications of DCF techniques may make capital decisions with a hidden bias against long-term projects, an inaccurate evaluation of options, or inappropriate estimations of expected inflation and risk. Social and psychological factors also can impede effective decisions on projects already introduced.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Spriggs, G D
In a previous paper, the composite exposure rate conversion factor (ECF) for nuclear fallout was calculated using a simple theoretical photon-transport model. The theoretical model was used to fill in the gaps in the FGR-12 table generated by ORNL. The FGR-12 table contains the individual conversion factors for approximate 1000 radionuclides. However, in order to calculate the exposure rate during the first 30 minutes following a nuclear detonation, the conversion factors for approximately 2000 radionuclides are needed. From a human-effects standpoint, it is also necessary to have the dose rate conversion factors (DCFs) for all 2000 radionuclides. The DCFs aremore » used to predict the whole-body dose rates that would occur if a human were standing in a radiation field of known exposure rate. As calculated by ORNL, the whole-body dose rate (rem/hr) is approximately 70% of the exposure rate (R/hr) at one meter above the surface. Hence, the individual DCFs could be estimated by multiplying the individual ECFs by 0.7. Although this is a handy rule-of-thumb, a more consistent (and perhaps, more accurate) method of estimating the individual DCFs for the missing radionuclides in the FGR-12 table is to use the linear relationship between DCF and total gamma energy released per decay. This relationship is shown in Figure 1. The DCFs for individual organs in the body can also be estimated from the estimated whole-body DCF. Using the DCFs given FGR-12, the ratio of the organ-specific DCFs to the whole-body DCF were plotted as a function of the whole-body DCF. From these plots, the asymptotic ratios were obtained (see Table 1). Using these asymptotic ratios, the organ-specific DCFs can be estimated using the estimated whole-body DCF for each of the missing radionuclides in the FGR-12 table. Although this procedure for estimating the organ-specific DCFs may over-estimate the value for some low gamma-energy emitters, having a finite value for the organ-specific DCFs in the table is probably better than having no value at all. A summary of the complete ECF and DCF values are given in Table 2.« less
Mazumder, Somnath; De, Rudranil; Sarkar, Souvik; Siddiqui, Asim Azhar; Saha, Shubhra Jyoti; Banerjee, Chinmoy; Iqbal, Mohd Shameel; Nag, Shiladitya; Debsharma, Subhashis; Bandyopadhyay, Uday
2016-12-01
Non-steroidal anti-inflammatory drugs (NSAIDs) are widely used to treat multiple inflammatory diseases and pain but severe gastric mucosal damage is the worst outcome of NSAID-therapy. Here we report that mitoTEMPO, a mitochondrially targeted superoxide (O 2 - ) scavenger protected as well as healed gastric injury induced by diclofenac (DCF), the most commonly used NSAID. Common existing therapy against gastric injury involves suppression of gastric acid secretion by proton pump inhibitors and histamine H 2 receptor antagonists; however, dyspepsia, vitamin B12 deficiency and gastric microfloral dysbalance are the major drawbacks of acid suppression. Interestingly, mitoTEMPO did not inhibit gastric acid secretion but offered gastroprotection by preventing DCF-induced generation of O 2 - due to mitochondrial respiratory chain failure and by preventing mitochondrial oxidative stress (MOS)-mediated mitopathology. MitoTEMPO even restored DCF-stimulated reduced fatty acid oxidation, mitochondrial depolarization and bioenergetic crisis in gastric mucosa. MitoTEMPO also prevented the activation of mitochondrial pathway of apoptosis and MOS-mediated proinflammatory signaling through NF-κB by DCF. Furthermore, mitoTEMPO when administered in rats with preformed gastric lesions expedited the healing of gastric injury and the healed stomach exhibited its normal physiology as evident from gastric acid and pepsin secretions under basal or stimulated conditions. Thus, in contrast to the existing antiulcer drugs, mitochondrially targeted O 2 - scavengers like mitoTEMPO may represent a novel class of gastroprotective molecules that does not affect gastric acid secretion and may be used in combination with DCF, keeping its anti-inflammatory action intact, while reducing its gastrodamaging effects. Copyright © 2016 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Cui, Zhiping; Liu, Shaopu; Liu, Zhongfang; Li, Yuanfang; Hu, Xiaoli; Tian, Jing
2013-10-01
A novel fluorescence quenching method for the determination of torasemide (TOR) with some dihalogenated fluorescein dyes as fluorescence probes was developed. In acidulous medium, TOR could interact with some dihalogenated fluorescein dyes such as dichlorofluorescein (DCF), dibromofluorescein (DBF) and diiodofluorescein (DIF) to form binary complexes, which could lead to fluorescence quenching of above dihalogenated fluorescein dyes. The maximum fluorescence emission wavelengths were located at 532 nm (TOR-DCF), 535 nm (TOR-DBF) and 554 nm (TOR-DIF). The relative fluorescence intensities (ΔF = F0 - F) were proportional to the concentration of TOR in certain ranges. The detection limits were 4.8 ng mL-1 for TOR-DCF system, 9.8 ng mL-1 for TOR-DBF system and 35.1 ng mL-1 for TOR-DIF system. The optimum reaction conditions, influencing factors were studied; and the effect of coexisting substances was investigated owing to the highest sensitivity of TOR-DCF system. In addition, the reaction mechanism, composition and structure of the complex were discussed by quantum chemical calculation and Job's method. The fluorescence quenching of dihalogenated fluorescein dyes by TOR was a static quenching process judging from the effect of temperature and the Stern-Volmer plots. The method was satisfactorily applied to the determination of TOR in tablets and human urine samples.
Zhou, Shiqi
2006-06-01
A second-order direct correlation function (DCF) from solving the polymer-RISM integral equation is scaled up or down by an equation of state for bulk polymer, the resultant scaling second-order DCF is in better agreement with corresponding simulation results than the un-scaling second-order DCF. When the scaling second-order DCF is imported into a recently proposed LTDFA-based polymer DFT approach, an originally associated adjustable but mathematically meaningless parameter now becomes mathematically meaningful, i.e., the numerical value lies now between 0 and 1. When the adjustable parameter-free version of the LTDFA is used instead of the LTDFA, i.e., the adjustable parameter is fixed at 0.5, the resultant parameter-free version of the scaling LTDFA-based polymer DFT is also in good agreement with the corresponding simulation data for density profiles. The parameter-free version of the scaling LTDFA-based polymer DFT is employed to investigate the density profiles of a freely jointed tangent hard sphere chain near a variable sized central hard sphere, again the predictions reproduce accurately the simulational results. Importance of the present adjustable parameter-free version lies in its combination with a recently proposed universal theoretical way, in the resultant formalism, the contact theorem is still met by the adjustable parameter associated with the theoretical way.
Saravanan, Manoharan; Karthika, Subramanian; Malarvizhi, Annamalai; Ramesh, Mathan
2011-11-15
Investigation on the toxic effects of pharmaceutical drugs namely clofibric acid (CA) and diclofenac (DCF) were studied in a common carp Cyprinus carpio at different concentrations such as 1, 10 and 100 μg L(-1) for a short-term period of 96 h under static bioassay method. At all concentrations, red blood cell (RBC), plasma sodium (Na(+)), potassium (K(+)), and glutamate oxaloacetate transaminase (GOT) levels were decreased in fish treated with CA and DCF. Contrastingly, white blood cell (WBC), plasma glucose, protein, lactate dehydrogenase (LDH) and gill Na(+)/K(+)-ATPase level were increased. However, a mixed trend was observed in hemoglobin (Hb), hematocrit (Hct), plasma chloride (Cl(-)), mean cellular volume (MCV), mean cellular hemoglobin (MCH), mean cellular hemoglobin concentration (MCHC) and glutamate pyruvate transaminase (GPT) levels. There was a significant (P<0.01 and P<0.05) change in all parameters measured in fish exposed to different concentrations of CA and DCF. In summary, the alterations in hematological, biochemical, ionoregulatory and enzymological parameters can be used as biomarkers in monitoring the toxicity of CA and DCF in aquatic environment. However, more detailed studies on using of specific biomarkers to monitor the human pharmaceuticals are needed. Copyright © 2011 Elsevier B.V. All rights reserved.
Xiong, Xiaoqing; Song, Fengling; Wang, Jingyun; Zhang, Yukang; Xue, Yingying; Sun, Liangliang; Jiang, Na; Gao, Pan; Tian, Lu; Peng, Xiaojun
2014-07-09
Compared with fluorescence imaging utilizing fluorophores whose lifetimes are in the order of nanoseconds, time-resolved fluorescence microscopy has more advantages in monitoring target fluorescence. In this work, compound DCF-MPYM, which is based on a fluorescein derivative, showed long-lived luminescence (22.11 μs in deaerated ethanol) and was used in time-resolved fluorescence imaging in living cells. Both nanosecond time-resolved transient difference absorption spectra and time-correlated single-photon counting (TCSPC) were employed to explain the long lifetime of the compound, which is rare in pure organic fluorophores without rare earth metals and heavy atoms. A mechanism of thermally activated delayed fluorescence (TADF) that considers the long wavelength fluorescence, large Stokes shift, and long-lived triplet state of DCF-MPYM was proposed. The energy gap (ΔEST) of DCF-MPYM between the singlet and triplet state was determined to be 28.36 meV by the decay rate of DF as a function of temperature. The ΔE(ST) was small enough to allow efficient intersystem crossing (ISC) and reverse ISC, leading to efficient TADF at room temperature. The straightforward synthesis of DCF-MPYM and wide availability of its starting materials contribute to the excellent potential of the compound to replace luminescent lanthanide complexes in future time-resolved imaging technologies.
Development of a pneumatic high-angle-of-attack Flush Airdata Sensing (HI-FADS) system
NASA Technical Reports Server (NTRS)
Whitmore, Stephen A.; Moes, Timothy R.; Leondes, Cornelius T.
1992-01-01
The HI-FADS system design is an evolution of the FADS systems (e.g., Larson et al., 1980, 1987), which emphasizes the entire airdata system development. This paper describes the HI-FADS measurement system, with particular consideration given to the basic measurement hardware and the development of the HI-FADS aerodynamic model and the basic nonlinear regression algorithm. Algorithm initialization techniques are developed, and potential algorithm divergence problems are discussed. Data derived from HI-FADS flight tests are used to demonstrate the system accuracies and to illustrate the developed concepts and methods.
Air data system optimization using a genetic algorithm
NASA Technical Reports Server (NTRS)
Deshpande, Samir M.; Kumar, Renjith R.; Seywald, Hans; Siemers, Paul M., III
1992-01-01
An optimization method for flush-orifice air data system design has been developed using the Genetic Algorithm approach. The optimization of the orifice array minimizes the effect of normally distributed random noise in the pressure readings on the calculation of air data parameters, namely, angle of attack, sideslip angle and freestream dynamic pressure. The optimization method is applied to the design of Pressure Distribution/Air Data System experiment (PD/ADS) proposed for inclusion in the Aeroassist Flight Experiment (AFE). Results obtained by the Genetic Algorithm method are compared to the results obtained by conventional gradient search method.
Aissaoui, Salima; Ouled-Haddar, Houria; Sifour, Mohamed; Harrouche, Kamel; Sghaier, Haitham
2017-03-01
The presence of non-steroidal anti-inflammatory drugs, such as diclofenac (DCF), in the environment, is an emerging problem due to their harmful effects on non-target organisms, even at low concentrations. We studied the biodegradation of DCF by the strain D15 of Enterobacter hormaechei. The strain was isolated from an activated sludge, and identified as E. hormaechei based on its physiological characteristics and its 16 S RNA sequence. Using HPTLC and GC-MS methods, we demonstrated that this strain metabolized DCF at an elimination rate of 52.8%. In the presence of an external carbon source (glucose), the elimination rate increased to approximately 82%. GC-MS analysis detected and identified one metabolite as 1-(2,6-dichlorophenyl)-1,3-dihydro-2H-indol-2-one; it was produced as a consequence of dehydration and lactam formation reactions.
Framework and Method for Controlling a Robotic System Using a Distributed Computer Network
NASA Technical Reports Server (NTRS)
Sanders, Adam M. (Inventor); Strawser, Philip A. (Inventor); Barajas, Leandro G. (Inventor); Permenter, Frank Noble (Inventor)
2015-01-01
A robotic system for performing an autonomous task includes a humanoid robot having a plurality of compliant robotic joints, actuators, and other integrated system devices that are controllable in response to control data from various control points, and having sensors for measuring feedback data at the control points. The system includes a multi-level distributed control framework (DCF) for controlling the integrated system components over multiple high-speed communication networks. The DCF has a plurality of first controllers each embedded in a respective one of the integrated system components, e.g., the robotic joints, a second controller coordinating the components via the first controllers, and a third controller for transmitting a signal commanding performance of the autonomous task to the second controller. The DCF virtually centralizes all of the control data and the feedback data in a single location to facilitate control of the robot across the multiple communication networks.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Higuchi, Katsuhiko, E-mail: k.higu@kitasato-u.ac.jp; Komori, Shouko; Tanabe, Satoshi
Purpose: A previous phase 1 study suggested that definitive chemoradiation therapy with docetaxel, cisplatin, and 5-fluorouracil (DCF-R) is tolerable and active in patients with advanced esophageal cancer (AEC). This phase 2 study was designed to confirm the efficacy and toxicity of DCF-R in AEC. Methods and Materials: Patients with previously untreated thoracic AEC who had T4 tumors or M1 lymph node metastasis (M1 LYM), or both, received intravenous infusions of docetaxel (35 mg/m{sup 2}) and cisplatin (40 mg/m{sup 2}) on day 1 and a continuous intravenous infusion of 5-fluorouracil (400 mg/m{sup 2}/day) on days 1 to 5, every 2 weeks,more » plus concurrent radiation. The total radiation dose was initially 61.2 Gy but was lowered to multiple-field irradiation with 50.4 Gy to decrease esophagitis and late toxicity. Consequently, the number of cycles of DCF administered during radiation therapy was reduced from 4 to 3. The primary endpoint was the clinical complete response (cCR) rate. Results: Characteristics of the 42 subjects were: median age, 62 years; performance status, 0 in 14, 1 in 25, 2 in 3; TNM classification, T4M0 in 20, non-T4M1LYM in 12, T4M1LYM in 10; total scheduled radiation dose: 61.2 Gy in 12, 50.4 Gy in 30. The cCR rate was 52.4% (95% confidence interval [CI]: 37.3%-67.5%) overall, 33.3% in the 61.2-Gy group, and 60.0% in the 50.4-Gy group. The median progression-free survival was 11.1 months, and the median survival was 29.0 months with a survival rate of 43.9% at 3 years. Grade 3 or higher major toxicity consisted of leukopenia (71.4%), neutropenia (57.2%), anemia (16.7%), febrile neutropenia (38.1%), anorexia (31.0%), and esophagitis (28.6%). Conclusions: DCF-R frequently caused myelosuppression and esophagitis but was highly active and suggested to be a promising regimen in AEC. On the basis of efficacy and safety, a radiation dose of 50.4 Gy is recommended for further studies of DCF-R.« less
Oncogenes in Hematopoietic and Hepatic Fish Neoplasms
1990-09-01
8 + Histolo,-ically normal 0 0.04 4/12 - Cholangiocarcinoma 0.26 4.9 8/8 ... Results Histologically abnormal. 0.39 0.36 8/55 - nonneoplasticd Northern...transfection of medaka cholangiocarcinoma DNA, growth in soft DNA source DCF5 b DCF5 + DEX agar’ two plates which were independently transfected with...induced rhabdomyosarcoma 0 0 - + 8/16 DEN-induced focal biliary hyperplasia 0.77 0.53 - - 10/16 DEN-induced cholangiocarcinoma 5.0 5.0 + + 47/47 Tumors
Designing and Implementation of River Classification Assistant Management System
NASA Astrophysics Data System (ADS)
Zhao, Yinjun; Jiang, Wenyuan; Yang, Rujun; Yang, Nan; Liu, Haiyan
2018-03-01
In an earlier publication, we proposed a new Decision Classifier (DCF) for Chinese river classification based on their structures. To expand, enhance and promote the application of the DCF, we build a computer system to support river classification named River Classification Assistant Management System. Based on ArcEngine and ArcServer platform, this system implements many functions such as data management, extraction of river network, river classification, and results publication under combining Client / Server with Browser / Server framework.
Making real options really work.
van Putten, Alexander B; MacMillan, Ian C
2004-12-01
As a way to value growth opportunities, real options have had a difficult time catching on with managers. Many CFOs believe the method ensures the overvaluation of risky projects. This concern is legitimate, but abandoning real options as a valuation model isn't the solution. Companies that rely solely on discounted cash flow (DCF) analysis underestimate the value of their projects and may fail to invest enough in uncertain but highly promising opportunities. CFOs need not--and should not--choose one approach over the other. Far from being a replacement for DCF analysis, real options are an essential complement, and a project's total value should encompass both. DCF captures a base estimate of value; real options take into account the potential for big gains. This is not to say that there aren't problems with real options. As currently applied, they focus almost exclusively on the risks associated with revenues, ignoring the risks associated with a project's costs. It's also true that option valuations almost always ignore assets that an initial investment in a subsequently abandoned project will often leave the company. In this article, the authors present a simple formula for combining DCF and option valuations that addresses these two problems. Using an integrated approach, managers will, in the long run, select better projects than their more timid competitors while keeping risk under control. Thus, they will outperform their rivals in both the product and the capital markets.
Inverse Flush Air Data System (FADS) for Real Time Simulations
NASA Astrophysics Data System (ADS)
Madhavanpillai, Jayakumar; Dhoaya, Jayanta; Balakrishnan, Vidya Saraswathi; Narayanan, Remesh; Chacko, Finitha Kallely; Narayanan, Shyam Mohan
2017-12-01
Flush Air Data Sensing System (FADS) forms a mission critical sub system in future reentry vehicles. FADS makes use of surface pressure measurements from the nose cap of the vehicle for deriving the air data parameters of the vehicle such as angle of attack, angle of sideslip, Mach number, etc. These parameters find use in the flight control and guidance systems, and also assist in the overall mission management. The FADS under consideration in this paper makes use of nine pressure ports located in the nose cap of a technology demonstrator vehicle. In flight, the air data parameters are obtained from the FADS estimation algorithm using the pressure data at the nine pressure ports. But, these pressure data will not be available, for testing the FADS package during ground simulation. So, an inverse software to FADS which estimates the pressure data at the pressure ports for a given flight condition is developed. These pressure data at the nine ports will go as input to the FADS package during ground simulation. The software is run to generate the pressure data for the descent phase trajectory of the technology demonstrator. This data is used again to generate the air data parameters from FADS algorithm. The computed results from FADS algorithm match well with the trajectory data.
Weitzman, S; Wayne, A S; Arceci, R; Lipton, J M; Whitlock, J A
1999-11-01
Previous reports have suggested activity of the nucleoside analogues 2-chlorodeoxyadenosine (2-CdA) and 2'-deoxycoformycin (2'-DCF) in Langerhans cell histiocytosis (LCH). To assess the efficacy of 2-CdA and 2'-DCF as salvage therapy for LCH, a survey of members of the Histiocyte Society and a literature review were undertaken. Twenty-three patients treated with 2-CdA and 4 treated with 2'-DCF were found, age range 2 months to 49 years. All 15 survey patients had multiorgan involvement, and 14 were heavily pretreated. Doses of 2-CdA ranged from 0.1 mg/kg/day continuous infusion for 5-7 days (majority of patients) to 13 mg/m(2)/day for 5 days, for 1-6 courses. One of the 15 patients had an early death, 5 had no response (NR), 3 had partial response (PR), and 6 achieved complete response (CR). Among 8 published patients, 7 achieved stable CR and 1 NR. Among 4 patients treated with 2'-DCF (4 mg/m(2)/week for 8 weeks then q 2 weekly), 2 achieved CR for 16+ and 18+ months and 2 PR for 2 and 5 months. Toxicity consisted mainly of combined myelo- and immunosuppression but no significant infections occurred and there were no toxic deaths. A cumulative thrombocytopenia was noted, which in 1 case took up to 6 months to resolve. Transient gastrointestinal toxicity and elevation of liver enzymes was seen, and 2 patients developed renal tubular acidosis. The peripheral neuropathy reported in adult patients receiving high doses was not seen. 2-CdA and 2'-DCF appear to have a useful role in LCH and are worthy of prospective trial in patients unresponsive to routine therapy. Copyright 1999 Wiley-Liss, Inc.
Fumoto, Shoichi; Shibata, Tomotaka; Nishiki, Kohei; Tsukamoto, Yoshiyuki; Etoh, Tsuyoshi; Moriyama, Masatsugu; Shiraishi, Norio; Inomata, Masafumi
2017-01-01
Background Recently, neoadjuvant chemotherapy with docetaxel/cisplatin/5-fluorouracil (NAC-DCF) was identified as a novel strong regimen with a high rate of pathological complete response (pCR) in advanced esophageal cancer in Japan. Predicting pCR will contribute to the therapeutic strategy and the prevention of surgical invasion. However, a predictor of pCR after NAC-DCF has not yet been developed. The aim of this study was to identify a novel predictor of pCR in locally advanced esophageal cancer treated with NAC-DCF. Patients and methods A total of 32 patients who received NAC-DCF followed by esophagectomy between June 2013 and March 2016 were enrolled in this study. We divided the patients into the following 2 groups: pCR group (9 cases) and non-pCR group (23 cases), and compared gene expressions between these groups using DNA microarray data and KeyMolnet. Subsequently, a validation study of candidate molecular expression was performed in 7 additional cases. Results Seventeen molecules, including transcription factor E2F, T-cell-specific transcription factor, Src (known as “proto-oncogene tyrosine-protein kinase of sarcoma”), interferon regulatory factor 1, thymidylate synthase, cyclin B, cyclin-dependent kinase (CDK) 4, CDK, caspase-1, vitamin D receptor, histone deacetylase, MAPK/ERK kinase, bcl-2-associated X protein, runt-related transcription factor 1, PR domain zinc finger protein 1, platelet-derived growth factor receptor, and interleukin 1, were identified as candidate molecules. The molecules were mainly associated with pathways, such as transcriptional regulation by SMAD, RB/E2F, and STAT. The validation study indicated that 12 of the 17 molecules (71%) matched the trends of molecular expression. Conclusions A 17-molecule set that predicts pCR after NAC-DCF for locally advanced esophageal cancer was identified. PMID:29136005
Bozkaya, Yakup; Doğan, Mutlu; Yazıcı, Ozan; Erdem, Gökmen Umut; Demirci, Nebi Serkan; Zengin, Nurullah
2017-01-01
Alpha-fetoprotein producing gastric carcinoma (AFP-PGC) is a rare cancer for which limited data on the clinicopathological features and treatment modalities exist. The aim of this study was to compare the efficacy of modified docetaxel-cisplatin-5-fluorouracil (mDCF) as the first-line chemotherapy regimen in metastatic AFP-PGC and non-AFP-PGC. The patients diagnosed with metastatic gastric cancer who were given mDCF as first-line therapy were retrospectively reviewed. The patients with a basal serum AFP level over 9 ng/ml were defined as AFP-PGC patients. In total, 169 patients (34 with AFP-PGC and 135 with non-AFP-PGC) were included in this study. AFP-PGC patients had more liver metastases than non-AFP-PGC patients (p < 0.001). A decrease in basal AFP levels after three cycles of chemotherapy was significantly different in AFP-PGC group (p = 0.001). Overall disease control rate was 79.4% (partial response [PR] - 44.1%, stable disease [SD] - 35.3%), and 82.2% (complete response - 3%, PR - 36.2%, SD - 43%) in AFP-PGC and non-AFP-PGC patients, respectively. There was no difference between AFP-PGC and non-AFP-PGC groups in overall and progression-free survival rates (11.3 versus 11.4 months and 7.7 versus 7.1 months, respectively). Rates of grade 3-4 hematologic toxicity were 8.8% and 6.7% for neutropenia in AFP-PGC and non-AFP-PGC group, respectively and 5.9% and 7.4% for anemia. In conclusion, mDCF regimen is well-tolerated with acceptable toxicity outcomes in both AFP-PGC and non-AFP-PGC patients. A statistically significant decrease in AFP levels after mDCF regimen indicate that AFP might be considered as a supplemental marker of response to mDCF chemotherapy in AFP-PGC patients. However, further prospective clinical trials are required in this area. PMID:28273032
Farfán, Eduardo B; Labone, Thomas R; Staack, Gregory C; Cheng, Yung-Sung; Zhou, Yue; Varallo, Thomas P
2012-09-01
A sample of tritiated lanthanum nickel aluminum alloy (LaNi4.25Al0.75 or LANA.75) similar to that used at the Savannah River Site Tritium Facilities was analyzed to estimate the particle size distribution of this metal tritide powder and the rate at which this material dissolves in the human respiratory tract after it is inhaled. This information is used to calculate the committed effective dose received by a worker after inhaling the material. These doses, which were calculated using the same methodology given in the U.S. Department of Energy Tritium Handbook, are presented as inhalation intake-to-dose conversion factors (DCF). The DCF for this metal tritide was determined to be 9.4 × 10 Sv Bq, which is less than the DCF for tritiated water. Therefore, the radiation worker bioassay programs designed for tritiated water are adequate to monitor for intakes of this material.
Repurposing Drugs in Oncology (ReDO)—diclofenac as an anti-cancer agent
Pantziarka, Pan; Sukhatme, Vidula; Bouche, Gauthier; Meheus, Lydie; Sukhatme, Vikas P
2016-01-01
Diclofenac (DCF) is a well-known and widely used non-steroidal anti-inflammatory drug (NSAID), with a range of actions which are of interest in an oncological context. While there has long been an interest in the use of NSAIDs in chemoprevention, there is now emerging evidence that such drugs may have activity in a treatment setting. DCF, which is a potent inhibitor of COX-2 and prostaglandin E2 synthesis, displays a range of effects on the immune system, the angiogenic cascade, chemo- and radio-sensitivity and tumour metabolism. Both pre-clinical and clinical evidence of these effects, in multiple cancer types, is assessed and summarised and relevant mechanisms of action outlined. Based on this evidence the case is made for further clinical investigation of the anticancer effects of DCF, particularly in combination with other agents - with a range of possible multi-drug and multi-modality combinations outlined in the supplementary materials accompanying the main paper. PMID:26823679
Fiber fuse behavior in kW-level continuous-wave double-clad field laser
NASA Astrophysics Data System (ADS)
Jun-Yi, Sun; Qi-Rong, Xiao; Dan, Li; Xue-Jiao, Wang; Hai-Tao, Zhang; Ma-Li, Gong; Ping, Yan
2016-01-01
In this study, original experimental data for fiber fuse in kW-level continuous-wave (CW) high power double-clad fiber (DCF) laser are reported. The propagating velocity of the fuse is 9.68 m/s in a 3.1-kW Yb-doped DCF laser. Three other cases in Yb-doped DCF are also observed. We think that the ignition of fiber fuse is caused by thermal mechanism, and the formation of bullet-shaped tracks is attributed to the optical discharge and temperature gradient. The inducements of initial fuse and formation of bullet-shaped voids are analyzed. This investigation of fiber fuse helps better understand the fiber fuse behavior, in order to avoid the catastrophic destruction caused by fiber fuse in high power fiber laser. Project supported by the Key Laboratory of Science and Technology on High Energy Laser and China Academy of Engineering Physics (Grant No. 2014HEL02) and the National Natural Science Foundation of China (Grant No. 61307057).
Saravanan, Manoharan; Ramesh, Mathan; Petkam, Rakpong
2013-12-01
The extensive use of pharmaceuticals in human and veterinary medicine may enter the aquatic environment and pose a serious threat to non-target aquatic organisms like fish. In this study, Indian major carp Cirrhinus mrigala was exposed to different concentrations (1, 10 and 100 μg L⁻¹) of most commonly used pharmaceutical drugs clofibric acid (CA) and diclofenac (DCF) to evaluate its impacts on certain enzymological parameters during short- and long-term exposures. During short-term (96 h) exposure period, plasma glutamate oxaloacetate transaminase (GOT), glutamate pyruvate transaminase (GPT) and gill Na⁺/K⁺-ATPase activity were significantly altered at all concentrations of both the CA- and DCF-treated fish. In long-term exposure (35 days), gill Na⁺/K⁺-ATPase activity was found to be significantly increased at all concentration of CA and DCF exposures throughout the study period (except at the end of 7th day in 10 and 100 µg L⁻¹) . However, a biphasic trend was observed in plasma GOT and GPT activity when compared to the control groups. In both short- and long-term exposure, a significant (P < 0.01 and P < 0.05) changes were observed in all enzymological parameters of fish C. mrigala exposed to different concentrations of CA and DCF. The alterations of these enzymological parameters can be effectively used as potential biomarkers in monitoring of pharmaceutical toxicity in aquatic environment and organisms.
Kanakaraju, Devagi; Motti, Cherie A; Glass, Beverley D; Oelgemöller, Michael
2016-09-01
Given that drugs and their degradation products are likely to occur as concoctions in wastewater, the degradation of a mixture of two nonsteroidal anti-inflammatory drugs (NSAIDs), diclofenac (DCF) and naproxen (NPX), was investigated by solar photolysis and titanium dioxide (TiO2)-mediated solar photocatalysis using an immersion-well photoreactor. An equimolar ratio (1:1) of both NSAIDs in distilled water, drinking water, and river water was subjected to solar degradation. Solar photolysis of the DCF and NPX mixture was competitive particularly in drinking water and river water, as both drugs have the ability to undergo photolysis. However, the addition of TiO2 in the mixture significantly enhanced the degradation rate of both APIs compared to solar photolysis alone. Mineralization, as measured by chemical oxygen demand (COD), was incomplete under all conditions investigated. TiO2-mediated solar photocatalytic degradation of DCF and NPX mixtures produced 15 identifiable degradants corresponding to degradation of the individual NSAIDs, while two degradation products with much higher molecular weight than the parent NSAIDs were identified by liquid chromatography mass spectrometry (LC-MS) and Fourier transform-ion cyclotron resonance-mass spectrometry (FT-ICR-MS). This study showed that the solar light intensity and the water matrix appear to be the main factors influencing the overall performance of the solar photolysis and TiO2-mediated solar photocatalysis for degradation of DCF and NPX mixtures.
Reactive solute transport in an asymmetrical fracture-rock matrix system
NASA Astrophysics Data System (ADS)
Zhou, Renjie; Zhan, Hongbin
2018-02-01
The understanding of reactive solute transport in a single fracture-rock matrix system is the foundation of studying transport behavior in the complex fractured porous media. When transport properties are asymmetrically distributed in the adjacent rock matrixes, reactive solute transport has to be considered as a coupled three-domain problem, which is more complex than the symmetric case with identical transport properties in the adjacent rock matrixes. This study deals with the transport problem in a single fracture-rock matrix system with asymmetrical distribution of transport properties in the rock matrixes. Mathematical models are developed for such a problem under the first-type and the third-type boundary conditions to analyze the spatio-temporal concentration and mass distribution in the fracture and rock matrix with the help of Laplace transform technique and de Hoog numerical inverse Laplace algorithm. The newly acquired solutions are then tested extensively against previous analytical and numerical solutions and are proven to be robust and accurate. Furthermore, a water flushing phase is imposed on the left boundary of system after a certain time. The diffusive mass exchange along the fracture/rock matrixes interfaces and the relative masses stored in each of three domains (fracture, upper rock matrix, and lower rock matrix) after the water flushing provide great insights of transport with asymmetric distribution of transport properties. This study has the following findings: 1) Asymmetric distribution of transport properties imposes greater controls on solute transport in the rock matrixes. However, transport in the fracture is mildly influenced. 2) The mass stored in the fracture responses quickly to water flushing, while the mass stored in the rock matrix is much less sensitive to the water flushing. 3) The diffusive mass exchange during the water flushing phase has similar patterns under symmetric and asymmetric cases. 4) The characteristic distance which refers to the zero diffusion between the fracture and the rock matrix during the water flushing phase is closely associated with dispersive process in the fracture.
DoS detection in IEEE 802.11 with the presence of hidden nodes
Soryal, Joseph; Liu, Xijie; Saadawi, Tarek
2013-01-01
The paper presents a novel technique to detect Denial of Service (DoS) attacks applied by misbehaving nodes in wireless networks with the presence of hidden nodes employing the widely used IEEE 802.11 Distributed Coordination Function (DCF) protocols described in the IEEE standard [1]. Attacker nodes alter the IEEE 802.11 DCF firmware to illicitly capture the channel via elevating the probability of the average number of packets transmitted successfully using up the bandwidth share of the innocent nodes that follow the protocol standards. We obtained the theoretical network throughput by solving two-dimensional Markov Chain model as described by Bianchi [2], and Liu and Saadawi [3] to determine the channel capacity. We validated the results obtained via the theoretical computations with the results obtained by OPNET simulator [4] to define the baseline for the average attainable throughput in the channel under standard conditions where all nodes follow the standards. The main goal of the DoS attacker is to prevent the innocent nodes from accessing the channel and by capturing the channel’s bandwidth. In addition, the attacker strives to appear as an innocent node that follows the standards. The protocol resides in every node to enable each node to police other nodes in its immediate wireless coverage area. All innocent nodes are able to detect and identify the DoS attacker in its wireless coverage area. We applied the protocol to two Physical Layer technologies: Direct Sequence Spread Spectrum (DSSS) and Frequency Hopping Spread Spectrum (FHSS) and the results are presented to validate the algorithm. PMID:25685510
DoS detection in IEEE 802.11 with the presence of hidden nodes.
Soryal, Joseph; Liu, Xijie; Saadawi, Tarek
2014-07-01
The paper presents a novel technique to detect Denial of Service (DoS) attacks applied by misbehaving nodes in wireless networks with the presence of hidden nodes employing the widely used IEEE 802.11 Distributed Coordination Function (DCF) protocols described in the IEEE standard [1]. Attacker nodes alter the IEEE 802.11 DCF firmware to illicitly capture the channel via elevating the probability of the average number of packets transmitted successfully using up the bandwidth share of the innocent nodes that follow the protocol standards. We obtained the theoretical network throughput by solving two-dimensional Markov Chain model as described by Bianchi [2], and Liu and Saadawi [3] to determine the channel capacity. We validated the results obtained via the theoretical computations with the results obtained by OPNET simulator [4] to define the baseline for the average attainable throughput in the channel under standard conditions where all nodes follow the standards. The main goal of the DoS attacker is to prevent the innocent nodes from accessing the channel and by capturing the channel's bandwidth. In addition, the attacker strives to appear as an innocent node that follows the standards. The protocol resides in every node to enable each node to police other nodes in its immediate wireless coverage area. All innocent nodes are able to detect and identify the DoS attacker in its wireless coverage area. We applied the protocol to two Physical Layer technologies: Direct Sequence Spread Spectrum (DSSS) and Frequency Hopping Spread Spectrum (FHSS) and the results are presented to validate the algorithm.
Koenig, Steven C; Litwak, Kenneth N; Giridharan, Guruprasad A; Pantalos, George M; Dowling, Robert D; Prabhu, Sumanth D; Slaughter, Mark S; Sobieski, Michael A; Spence, Paul A
2008-01-01
The acute hemodynamic efficacy of an implantable counterpulsation device (CPD) was evaluated. The CPD is a valveless single port, 32-ml stroke volume blood chamber designed to be connected to the human axillary artery using a simple surface surgical procedure. Blood is drawn into the pump during systole and ejected during diastole. The acute hemodynamic effects of the 32-ml CPD were compared to a standard clinical 40-ml intra-aortic balloon pump (IABP) in calves (80 kg, n = 10). The calves were treated by a single oral dose of Monensin to produce a model of diminished cardiac function (DCF). The CPD and IABP produced similar increases in cardiac output (6% CPD vs. 5% IABP, p > 0.5) and reduction in left ventricular external work (14% CPD vs. 13% IABP, p > 0.5) compared to DCF (p < 0.05). However, the ratio of diastolic coronary artery flow to left ventricular external work increase from DCF baseline (p < 0.05) was greater with the CPD compared to the IABP (15% vs. 4%, p < 0.05). The CPD also produced a greater reduction in left ventricular myocardial oxygen consumption from DCF baseline (p < 0.05) compared to the IABP (13% vs. 9%, p < 0.05) despite each device providing similar improvements in cardiac output. There was no early indication of hemolysis, thrombus formation, or vascular injury. The CPD provides hemodynamic efficacy equivalent to an IABP and may become a therapeutic option for patients who may benefit from prolonged counterpulsation.
Koenig, Steven C.; Litwak, Kenneth N.; Giridharan, Guruprasad A.; Pantalos, George M.; Dowling, Robert D.; Prabhu, Sumanth D.; Slaughter, Mark S.; Sobieski, Michael A.; Spence, Paul A.
2010-01-01
The acute hemodynamic efficacy of an implantable counter-pulsation device (CPD) was evaluated. The CPD is a valveless single port, 32-ml stroke volume blood chamber designed to be connected to the human axillary artery using a simple surface surgical procedure. Blood is drawn into the pump during systole and ejected during diastole. The acute hemodynamic effects of the 32-ml CPD were compared to a standard clinical 40-ml intra-aortic balloon pump (IABP) in calves (80 kg, n = 10). The calves were treated by a single oral dose of Monensin to produce a model of diminished cardiac function (DCF). The CPD and IABP produced similar increases in cardiac output (6% CPD vs. 5% IABP, p > 0.5) and reduction in left ventricular external work (14% CPD vs. 13% IABP, p > 0.5) compared to DCF (p < 0.05). However, the ratio of diastolic coronary artery flow to left ventricular external work increase from DCF baseline (p < 0.05) was greater with the CPD compared to the IABP (15% vs. 4%, p < 0.05). The CPD also produced a greater reduction in left ventricular myocardial oxygen consumption from DCF baseline (p < 0.05) compared to the IABP (13% vs. 9%, p < 0.05) despite each device providing similar improvements in cardiac output. There was no early indication of hemolysis, thrombus formation, or vascular injury. The CPD provides hemodynamic efficacy equivalent to an IABP and may become a therapeutic option for patients who may benefit from prolonged counterpulsation. PMID:19033769
Lonappan, Linson; Rouissi, Tarek; Kaur Brar, Satinder; Verma, Mausam; Surampalli, Rao Y
2018-02-01
Biochars were prepared from feedstocks pinewood and pig manure. Biochar microparticles obtained through grinding were evaluated for the removal of emerging contaminant diclofenac (DCF) and the underlying mechanism were thoroughly studied. Characterization of biochar was carried out using particle size analyzer, SEM, BET, FT-IR, XRD, XPS and zeta potential instrument. Pig manure biochar (BC-PM) exhibited excellent removal efficiency (99.6%) over pine wood biochar (BC-PW) at 500 µg L -1 of DCF (environmentally significant concentration). Intraparticle diffusion was found to be the major process facilitated the adsorption. BC-PW followed pseudo first-order kinetics whereas BC-PM followed pseudo second-order kinetics. Pine wood biochar was largely affected by pH variations whereas for pig manure biochar, pH effects were minimal owing to its surface functional groups and DCF hydrophobicity. Thermodynamics, presence of co-existing ions, initial adsorbate concentration and particles size played substantial role in adsorption. Various isotherms models were also studied and results are presented. Copyright © 2017 Elsevier Ltd. All rights reserved.
Beaudette, Kathy; Baac, Hyoung Won; Madore, Wendy-Julie; Villiger, Martin; Godbout, Nicolas; Bouma, Brett E; Boudoux, Caroline
2015-04-01
Double-clad fiber (DCF) is herein used in conjunction with a double-clad fiber coupler (DCFC) to enable simultaneous and co-registered optical coherence tomography (OCT) and laser tissue coagulation. The DCF allows a single channel fiber-optic probe to be shared: i.e. the core propagating the OCT signal while the inner cladding delivers the coagulation laser light. We herein present a novel DCFC designed and built to combine both signals within a DCF (>90% of single-mode transmission; >65% multimode coupling). Potential OCT imaging degradation mechanisms are also investigated and solutions to mitigate them are presented. The combined DCFC-based system was used to induce coagulation of an ex vivo swine esophagus allowing a real-time assessment of thermal dynamic processes. We therefore demonstrate a DCFC-based system combining OCT imaging with laser coagulation through a single fiber, thus enabling both modalities to be performed simultaneously and in a co-registered manner. Such a system enables endoscopic image-guided laser marking of superficial epithelial tissues or laser thermal therapy of epithelial lesions in pathologies such as Barrett's esophagus.
Beaudette, Kathy; Baac, Hyoung Won; Madore, Wendy-Julie; Villiger, Martin; Godbout, Nicolas; Bouma, Brett E.; Boudoux, Caroline
2015-01-01
Double-clad fiber (DCF) is herein used in conjunction with a double-clad fiber coupler (DCFC) to enable simultaneous and co-registered optical coherence tomography (OCT) and laser tissue coagulation. The DCF allows a single channel fiber-optic probe to be shared: i.e. the core propagating the OCT signal while the inner cladding delivers the coagulation laser light. We herein present a novel DCFC designed and built to combine both signals within a DCF (>90% of single-mode transmission; >65% multimode coupling). Potential OCT imaging degradation mechanisms are also investigated and solutions to mitigate them are presented. The combined DCFC-based system was used to induce coagulation of an ex vivo swine esophagus allowing a real-time assessment of thermal dynamic processes. We therefore demonstrate a DCFC-based system combining OCT imaging with laser coagulation through a single fiber, thus enabling both modalities to be performed simultaneously and in a co-registered manner. Such a system enables endoscopic image-guided laser marking of superficial epithelial tissues or laser thermal therapy of epithelial lesions in pathologies such as Barrett’s esophagus. PMID:25909013
Attention-deficit hyperactivity disorder, drug companies and the internet.
Mitchell, Jessica; Read, John
2012-01-01
This study investigated the influence of drug-company funding on websites about attention-deficit hyperactivity disorder (ADHD). Websites in the top 60 for either Google or Yahoo!Xtra with information about causation and treatment were analysed. Likert scales, based on those used in previous similar studies, were developed to rate aetiological explanations and recommended treatment approaches, on a dimension from psycho-social to biological. Overall, the quality of information on websites was poor with a strong bias towards bio-genetic aetiological explanations of ADHD. Twenty-one of the 57 websites (37%) were funded by drug companies. The drug-company funded (DCF) websites were significantly more likely than non-DCF websites to recommend medication rather than psycho-social treatments. The selective lack of consideration of psycho-social treatments by DCF websites is discussed in relation to the relevant research literature, including the evidence in favour of a multimodal approach. The findings, which are consistent with previous similar studies in relation to websites about adult mental health problems, confirm that the pharmaceutical industry is seeking to influence public opinion via the internet.
Motoc, Sorina; Manea, Florica; Iacob, Adriana; Martinez-Joaristi, Alberto; Gascon, Jorge; Pop, Aniela; Schoonman, Joop
2016-10-17
In this study, the detection protocols for the individual, selective, and simultaneous determination of ibuprofen (IBP) and diclofenac (DCF) in aqueous solutions have been developed using HKUST-1 metal-organic framework-carbon nanofiber composite (HKUST-CNF) electrode. The morphological and electrical characterization of modified composite electrode prepared by film casting was studied by scanning electronic microscopy and four-point-probe methods. The electrochemical characterization of the electrode by cyclic voltammetry (CV) was considered the reference basis for the optimization of the operating conditions for chronoamperometry (CA) and multiple-pulsed amperometry (MPA). This electrode exhibited the possibility to selectively detect IBP and DCF by simple switching the detection potential using CA. However, the MPA operated under optimum working conditions of four potential levels selected based on CV shape in relation to the potential value, pulse time, and potential level number, and order allowed the selective/simultaneous detection of IBP and DCF characterized by the enhanced detection performance. For this application, the HKUST-CNF electrode exhibited a good stability and reproducibility of the results was achieved.
Motoc, Sorina; Manea, Florica; Iacob, Adriana; Martinez-Joaristi, Alberto; Gascon, Jorge; Pop, Aniela; Schoonman, Joop
2016-01-01
In this study, the detection protocols for the individual, selective, and simultaneous determination of ibuprofen (IBP) and diclofenac (DCF) in aqueous solutions have been developed using HKUST-1 metal-organic framework-carbon nanofiber composite (HKUST-CNF) electrode. The morphological and electrical characterization of modified composite electrode prepared by film casting was studied by scanning electronic microscopy and four-point-probe methods. The electrochemical characterization of the electrode by cyclic voltammetry (CV) was considered the reference basis for the optimization of the operating conditions for chronoamperometry (CA) and multiple-pulsed amperometry (MPA). This electrode exhibited the possibility to selectively detect IBP and DCF by simple switching the detection potential using CA. However, the MPA operated under optimum working conditions of four potential levels selected based on CV shape in relation to the potential value, pulse time, and potential level number, and order allowed the selective/simultaneous detection of IBP and DCF characterized by the enhanced detection performance. For this application, the HKUST-CNF electrode exhibited a good stability and reproducibility of the results was achieved. PMID:27763509
Design and Calibration of the X-33 Flush Airdata Sensing (FADS) System
NASA Technical Reports Server (NTRS)
Whitmore, Stephen A.; Cobleigh, Brent R.; Haering, Edward A.
1998-01-01
This paper presents the design of the X-33 Flush Airdata Sensing (FADS) system. The X-33 FADS uses a matrix of pressure orifices on the vehicle nose to estimate airdata parameters. The system is designed with dual-redundant measurement hardware, which produces two independent measurement paths. Airdata parameters that correspond to the measurement path with the minimum fit error are selected as the output values. This method enables a single sensor failure to occur with minimal degrading of the system performance. The paper shows the X-33 FADS architecture, derives the estimating algorithms, and demonstrates a mathematical analysis of the FADS system stability. Preliminary aerodynamic calibrations are also presented here. The calibration parameters, the position error coefficient (epsilon), and flow correction terms for the angle of attack (delta alpha), and angle of sideslip (delta beta) are derived from wind tunnel data. Statistical accuracy of' the calibration is evaluated by comparing the wind tunnel reference conditions to the airdata parameters estimated. This comparison is accomplished by applying the calibrated FADS algorithm to the sensed wind tunnel pressures. When the resulting accuracy estimates are compared to accuracy requirements for the X-33 airdata, the FADS system meets these requirements.
Assessment of the Broadleaf Crops Leaf Area Index Product from the Terra MODIS Instrument
NASA Technical Reports Server (NTRS)
Tan, Bin; Hu, Jiannan; Huang, Dong; Yang, Wenze; Zhang, Ping; Shabanov, Nikolay V.; Knyazikhin, Yuri; Nemani, Ramakrishna R.; Myneni, Ranga B.
2005-01-01
The first significant processing of Terra MODIS data, called Collection 3, covered the period from November 2000 to December 2002. The Collection 3 leaf area index (LAI) and fraction vegetation absorbed photosynthetically active radiation (FPAR) products for broadleaf crops exhibited three anomalies (a) high LAI values during the peak growing season, (b) differences in LAI seasonality between the radiative transfer-based main algorithm and the vegetation index based back-up algorithm, and (c) too few retrievals from the main algorithm during the summer period when the crops are at full flush. The cause of these anomalies is a mismatch between reflectances modeled by the algorithm and MODIS measurements. Therefore, the Look-Up-Tables accompanying the algorithm were revised and implemented in Collection 4 processing. The main algorithm with the revised Look-Up-Tables generated retrievals for over 80% of the pixels with valid data. Retrievals from the back-up algorithm, although few, should be used with caution as they are generated from surface reflectances with high uncertainties.
High temperature sensor properties of a specialty double cladding fiber
NASA Astrophysics Data System (ADS)
Zhou, Ting; Pang, Fufei; Wang, Tingyun
2011-12-01
A simple high temperature fiber sensor is proposed and demonstrated. The sensor head is made of a short section of specialty double cladding fiber (DCF). The DCF consists of a depressed inner cladding which is boron (B)-doped silica. Through an evanescent wave, the cladding mode can be excited, and thus the transmission presents a resonant spectral dip. The high temperature sensing properties was studied according to the shift of the transmission spectrum shifts. With increasing the temperature from 28 °C to 850 °C, the resonant spectrum shifts to longer wavelengths. The sensitivity is 0.112 nm / °C.
NASA Technical Reports Server (NTRS)
Whitmore, Stephen A.; Moes, Timothy R.
1994-01-01
Presented is a feasibility and error analysis for a hypersonic flush airdata system on a hypersonic flight experiment (HYFLITE). HYFLITE heating loads make intrusive airdata measurement impractical. Although this analysis is specifically for the HYFLITE vehicle and trajectory, the problems analyzed are generally applicable to hypersonic vehicles. A layout of the flush-port matrix is shown. Surface pressures are related airdata parameters using a simple aerodynamic model. The model is linearized using small perturbations and inverted using nonlinear least-squares. Effects of various error sources on the overall uncertainty are evaluated using an error simulation. Error sources modeled include boundarylayer/viscous interactions, pneumatic lag, thermal transpiration in the sensor pressure tubing, misalignment in the matrix layout, thermal warping of the vehicle nose, sampling resolution, and transducer error. Using simulated pressure data for input to the estimation algorithm, effects caused by various error sources are analyzed by comparing estimator outputs with the original trajectory. To obtain ensemble averages the simulation is run repeatedly and output statistics are compiled. Output errors resulting from the various error sources are presented as a function of Mach number. Final uncertainties with all modeled error sources included are presented as a function of Mach number.
Sifuna, Fred W; Orata, Francis; Okello, Veronica; Jemutai-Kimosop, Selly
2016-09-18
In this study, the electro-oxidation capacities of Na2SO4 and potassium phosphate buffer supporting electrolytes were tested and compared for destruction of the sulfamethoxazole (SMX) and diclofenac (DCF) on platinum (Pt) electrode and graphite carbon electrode in aqueous medium. The suitability of pharmaceutical active compounds (PhACs) for electrochemical oxidation was tested by cyclic voltammetry (CV) technique performed in the potential range -1.5 to +1.5 V versus Ag/AgCl, which confirmed the electro-activity of the selected PhACs. The degradation and mineralization were monitored by ultraviolet (UV)-Vis spectrophotometry and HPLC. 0.1 M Na2SO4 supporting electrolyte was found to be more effective for mineralization of SMX and DCF, with efficiency of 15-30% more than the 0.1 M phosphate buffer supporting electrolyte on the platinum (Pt) and carbon electrodes. The Pt electrode showed better performance in the degradation of the two PhACs while under the same conditions than the carbon electrode for both 0.1 M Na2SO4 and 0.1 M potassium phosphate buffer supporting electrolytes. The SMX and DCF degradation kinetics best fitted the second-order reaction, with rate constants ranging between 0.000389 and 0.006 mol(2) L(-2) min(-1) and correlation coefficient (R(2)) above 0.987. The second-order degradation kinetics indicated that the rate-determining step in the degradation could be a chemical process, thus suggesting the active involvement of electrolyte radical species in the degradation of SMX and DCF. Results obtained from a real field sample showed a more than 98% removal of the PhACs from the wastewater by electrochemical degradation.
Ravindra, Kodihalli C.; Large, Emma; Young, Carissa L.; Rivera-Burgos, Dinelia; Yu, Jiajie; Cirit, Murat; Hughes, David J.; Wishnok, John S.; Lauffenburger, Douglas A.; Griffith, Linda G.
2017-01-01
In vitro hepatocyte culture systems have inherent limitations in capturing known human drug toxicities that arise from complex immune responses. Therefore, we established and characterized a liver immunocompetent coculture model and evaluated diclofenac (DCF) metabolic profiles, in vitro–in vivo clearance correlations, toxicological responses, and acute phase responses using liquid chromatography–tandem mass spectrometry. DCF biotransformation was assessed after 48 hours of culture, and the major phase I and II metabolites were similar to the in vivo DCF metabolism profile in humans. Further characterization of secreted bile acids in the medium revealed that a glycine-conjugated bile acid was a sensitive marker of dose-dependent toxicity in this three-dimensional liver microphysiological system. Protein markers were significantly elevated in the culture medium at high micromolar doses of DCF, which were also observed previously for acute drug-induced toxicity in humans. In this immunocompetent model, lipopolysaccharide treatment evoked an inflammatory response that resulted in a marked increase in the overall number of acute phase proteins. Kupffer cell–mediated cytokine release recapitulated an in vivo proinflammatory response exemplified by a cohort of 11 cytokines that were differentially regulated after lipopolysaccharide induction, including interleukin (IL)-1β, IL-1Ra, IL-6, IL-8, IP-10, tumor necrosis factor-α, RANTES (regulated on activation normal T cell expressed and secreted), granulocyte colony-stimulating factor, macrophage colony-stimulating factor, macrophage inflammatory protein-1β, and IL-5. In summary, our findings indicate that three-dimensional liver microphysiological systems may serve as preclinical investigational platforms from the perspective of the discovery of a set of clinically relevant biomarkers including potential reactive metabolites, endogenous bile acids, excreted proteins, and cytokines to predict early drug-induced liver toxicity in humans. PMID:28450578
Effective light coupling in reflective fiber optic distance sensors using a double-clad fiber
NASA Astrophysics Data System (ADS)
Werzinger, Stefan; Härteis, Lisa; Köhler, Aaron; Engelbrecht, Rainer; Schmauss, Bernhard
2017-04-01
Many fiber optic distance sensors use a reflective configuration, where a light beam is launched from an optical fiber, reflected from a target and coupled back into the fiber. While singlemode fibers (SMF) provide low-loss, high-performance components and a well-defined output beam, the coupling of the reflected light into the SMF is very sensitive to mechanical misalignments and scattering at the reflecting target. In this paper we use a double-clad fiber (DCF) and a DCF coupler to obtain an enhanced multimodal coupling of reflected light into the fiber. Increased power levels and robustness are achieved compared to a pure SMF configuration.
Le Guet, Thibaut; Hsini, Ilham; Labanowski, Jérôme; Mondamert, Leslie
2018-05-01
Sorption of pharmaceuticals onto sediments is frequently related to organic matter content. Thus, the present work aimed to compare the effect of humic substances (HS) extracted from a river sediment versus Aldrich (HS) on the sorption of selected pharmaceuticals onto this river sediment. The results exhibited no "unique" effect of the presence of HS from the same origin. Thus, the sediment HS increased the sorption of sulfamethoxazole (SMX), diclofenac (DCF), and trimethoprim (TMP), but reduced the sorption of atenolol (ATN). The presence of Aldrich HS increased the sorption of TMP and ATN and decreased the sorption of SMX and DCF. Fluorescence quenching measurements revealed that these effects cannot be explained only by the presence of pharmaceutical HS associations. The use of several sorption models suggested that the sorption of SMX, DCF, and ATN involves multilayer mechanisms. Furthermore, it was pointed out that the presence of HS does not change the sorption mechanisms although it was observed interaction between HS and the sediment. Indeed, the sediment HS sorbs onto the sediment whereas the Aldrich HS tends to mobilize organic compounds from the sediment to the solution.
Development of a Flush Airdata Sensing System on a Sharp-Nosed Vehicle for Flight at Mach 3 to 8
NASA Technical Reports Server (NTRS)
Davis, Mark C.; Pahle, Joseph W.; White, John Terry; Marshall, Laurie A.; Mashburn, Michael J.; Franks, Rick
2000-01-01
NASA Dryden Flight Research Center has developed a flush airdata sensing (FADS) system on a sharp-nosed, wedge-shaped vehicle. This paper details the design and calibration of a real-time angle-of-attack estimation scheme developed to meet the onboard airdata measurement requirements for a research vehicle equipped with a supersonic-combustion ramjet engine. The FADS system has been designed to perform in flights at Mach 3-8 and at -6 deg - 12 deg angle of attack. The description of the FADS architecture includes port layout, pneumatic design, and hardware integration. Predictive models of static and dynamic performance are compared with wind-tunnel results across the Mach and angle-of-attack range. Results indicate that static angle-of-attack accuracy and pneumatic lag can be adequately characterized and incorporated into a real-time algorithm.
Development of a Flush Airdata Sensing System on a Sharp-Nosed Vehicle for Flight at Mach 3 to 8
NASA Technical Reports Server (NTRS)
Davis, Mark C.; Pahle, Joseph W.; White, John Terry; Marshall, Laurie A.; Mashburn, Michael J.; Franks, Rick
2000-01-01
NASA Dryden Flight Research Center has developed a flush airdata sensing (FADS) system on a sharp-nosed, wedge-shaped vehicle. This paper details the design and calibration of a real-time angle-of-attack estimation scheme developed to meet the onboard airdata measurement requirements for a research vehicle equipped with a supersonic-combustion ramjet engine. The FADS system has been designed to perform in flights at speeds between Mach 3 and Mach 8 and at angles of attack between -6 deg. and 12 deg. The description of the FADS architecture includes port layout, pneumatic design, and hardware integration. Predictive models of static and dynamic performance are compared with wind-tunnel results across the Mach and angle-of-attack range. Results indicate that static angle-of-attack accuracy and pneumatic lag can be adequately characterized and incorporated into a real-time algorithm.
In-flight demonstration of a Real-Time Flush Airdata Sensing (RT-FADS) system
NASA Technical Reports Server (NTRS)
Whitmore, Stephen A.; Davis, Roy J.; Fife, John Michael
1995-01-01
A prototype real-time flush airdata sensing (RT-FADS) system has been developed and flight tested at the NASA Dryden Flight Research Center. This system uses a matrix of pressure orifices on the vehicle nose to estimate airdata parameters in real time using nonlinear regression. The algorithm is robust to sensor failures and noise in the measured pressures. The RT-FADS system has been calibrated using inertial trajectory measurements that were bootstrapped for atmospheric conditions using meteorological data. Mach numbers as high as 1.6 and angles of attack greater than 45 deg have been tested. The system performance has been evaluated by comparing the RT-FADS to the ship system airdata computer measurements to give a quantitative evaluation relative to an accepted measurement standard. Nominal agreements of approximately 0.003 in Mach number and 0.20 deg in angle of attack and angle of sideslip have been achieved.
Analysis and Results from a Flush Airdata Sensing System in Close Proximity to Firing Rocket Nozzles
NASA Technical Reports Server (NTRS)
Ali, Aliyah N.; Borrer, Jerry L.
2013-01-01
This paper presents information regarding the nosecap Flush Airdata Sensing (FADS) system on Orion’s Pad Abort 1 (PA-1) vehicle. The purpose of the nosecap FADS system was to test whether or not useful data could be obtained from a FADS system if it was placed in close proximity to firing rocket nozzles like the Attitude Control Motor (ACM) nozzles on the PA-1 Launch Abort System. The nosecap FADS system used pressure measurements from a series of pressure ports which were arranged in a cruciform pattern and flush with the surface of the vehicle to estimate values of angle of attack, angle of sideslip, Mach number, impact pressure, and freestream static pressure. This paper will present the algorithms employed by the FADS system along with the development of the calibration datasets and a comparison of the final results to the Best Estimated Trajectory (BET) data for PA-1. Also presented in this paper is a Computational Fluid Dynamics (CFD) study to explore the impact of the ACM on the nosecap FADS system. The comparison of the nosecap FADS system results to the BET and the CFD study showed that more investigation is needed to quantify the impact of the firing rocket motors on the FADS system.
Principles and performance of tapered fiber lasers: from uniform to flared geometry.
Kerttula, Juho; Filippov, Valery; Chamorovskii, Yuri; Ustimchik, Vasily; Golant, Konstantin; Okhotnikov, Oleg G
2012-10-10
We have studied the recently demonstrated concept of fiber lasers based on active tapered double-clad fiber (T-DCF) in copropagating and counterpropagating configurations, both theoretically and experimentally, and compared the performance to fiber lasers based on conventional cylindrical fibers in end-pumped configurations. Specific properties of T-DCFs were considered theoretically using a rate-equation model developed for tapered fibers, and a detailed comparative study was carried out experimentally. Furthermore, we have studied mode coupling effects in long adiabatic tapers due to coiling and local bending. The results allow us to conclude that, with proper fiber design, the T-DCF technology offers a high-potential alternative for bright, cost-effective fiber devices.
Hu, Liuyi; Zheng, Jing; Zhao, Kang; Deng, Anping; Li, Jianguo
2018-03-15
In this study, a novel competition-type electrochemiluminescent (ECL) immunosensor for detecting diclofenac (DCF) was fabricated with graphene oxide coupled graphite-like carbon nitride (GO-g-C 3 N 4 ) as signal probe for the first time. The ECL intensity of carboxylated g-C 3 N 4 was significantly enhanced after being combined with graphene oxide (GO) which exhibited excellent charge-transport property. The sensing platform was constructed by multiwalled carbon nanotubes and gold nanoparticles (MWCNTs-AuNPs), which not only provided an effective matrix for immobilizing a large amount of coating antigen but also facilitated the electronic transmission rate to enhance the ECL intensity. Based on the synergistic effect of GO-g-C 3 N 4 and MWCNTs-AuNPs composite, the proposed sensor showed high sensitivity, good stability, and wide linearity for the detection of DCF in the range of 0.005-1000ngmL -1 with a detection limit of 1.7pgmL -1 . Furthermore, the developed immunoassay has been applied to real samples with satisfactory results. Therefore, this work provided a promising method for the detection of DCF and other small molecular compounds in the future. Copyright © 2017 Elsevier B.V. All rights reserved.
Advances in engineering of high contrast CARS imaging endoscopes
Deladurantaye, Pascal; Paquet, Alex; Paré, Claude; Zheng, Huimin; Doucet, Michel; Gay, David; Poirier, Michel; Cormier, Jean-François; Mermut, Ozzy; Wilson, Brian C.; Seibel, Eric J.
2014-01-01
The translation of CARS imaging towards real time, high resolution, chemically selective endoscopic tissue imaging applications is limited by a lack of sensitivity in CARS scanning probes sufficiently small for incorporation into endoscopes. We have developed here a custom double clad fiber (DCF)-based CARS probe which is designed to suppress the contaminant Four-Wave-Mixing (FWM) background generated within the fiber and integrated it into a fiber based scanning probe head of a few millimeters in diameter. The DCF includes a large mode area (LMA) core as a first means of reducing FWM generation by ~3 dB compared to commercially available, step-index single mode fibers. A micro-fabricated miniature optical filter (MOF) was grown on the distal end of the DCF to block the remaining FWM background from reaching the sample. The resulting probe was used to demonstrate high contrast images of polystyrene beads in the forward-CARS configuration with > 10 dB suppression of the FWM background. In epi-CARS geometry, images exhibited lower contrast due to the leakage of MOF-reflected FWM from the fiber core. Improvements concepts for the fiber probe are proposed for high contrast epi-CARS imaging to enable endoscopic implementation in clinical tissue assessment contexts, particularly in the early detection of endoluminal cancers and in tumor margin assessment. PMID:25401538
Plakas, Konstantinos V; Sklari, Stella D; Yiankakis, Dimitrios A; Sideropoulos, Georgios Th; Zaspalis, Vassilis T; Karabelas, Anastasios J
2016-03-15
To assess the performance of a novel 'filter'-type electro-Fenton (EF) device, results are reported from pilot-scale studies of continuous water treatment, to degrade diclofenac (DCF), a typical organic micro-pollutant, with no addition of oxidants. The novel 'filter' consisted of three pairs of anode/cathode electrodes made of carbon felt, with cathodes impregnated with iron nanoparticles (γ-Fe2O3/F3O4 oxides). The best 'filter' performance was obtained at applied potential of 2 V and low water superficial velocities (∼0.09 cm/s), i.e., the mineralization current efficiency (MCE) was >20%, during continuous steady state treatment of tap water with low DCF concentrations (16 μg/L). The EF 'filter' exhibited satisfactory stability regarding both electrode integrity (no iron leaching) and removal efficiency, even after multiple filtration/oxidation treatment cycles, achieving (under steady conditions) DCF and TOC removal 85% and 36%, respectively. This performance is considered satisfactory because the EF process took place under rather unfavorable conditions, such as neutral pH, low dissolved O2 concentration, low electrical conductivity, and presence of natural organic matter and inorganic ions in tap water. Ongoing R&D is aimed at 'filter' development and optimization for practical applications. Copyright © 2016 Elsevier Ltd. All rights reserved.
Amiri Arimi, Somayeh; Mohseni Bandpei, Mohammad Ali; Javanshir, Khodabakhsh; Rezasoltani, Asghar; Biglarian, Akbar
2017-08-01
Neck pain is one of the major public health problems, which has a great impact on people's lives. The purpose of this study was to systematically review published studies conducted on the effect of different exercise programs on activity, size, endurance, and strength of deep cervical flexor (DCF) muscles in patients with chronic neck pain. The PubMed, Science Direct, OVID, Google scholar, Cochrane Library, and Physiotherapy Evidence Databases were searched to determine relevant articles published from 1990 to March 2016. The articles were qualitatively assessed based on the Physiotherapy Evidence Databases scale for randomized controlled trials studies. Nine articles were identified and evaluated in the final analysis. Four studies had moderate quality, and five studies had good quality. From those nine studies, eight studies gave support to the effectiveness of specific low-load exercise training on DCF muscles parameters, while one study reported no significant difference between this exercise and other cervical exercise programs. The results of reviewed studies are in favor of specific low-load craniocervical flexion exercise, which seems to be a highly effective exercise regimen compared to other types of exercises in improving DCF muscles impairments in patients with chronic neck pain.
Variable-Volume Flushing (V-VF) device for water conservation in toilets
NASA Technical Reports Server (NTRS)
Jasper, Louis J., Jr.
1993-01-01
Thirty five percent of residential indoor water used is flushed down the toilet. Five out of six flushes are for liquid waste only, which requires only a fraction of the water needed for solid waste. Designers of current low-flush toilets (3.5-gal. flush) and ultra-low-flush toilets (1.5-gal. flush) did not consider the vastly reduced amount of water needed to flush liquid waste versus solid waste. Consequently, these toilets are less practical than desired and can be improved upon for water conservation. This paper describes a variable-volume flushing (V-VF) device that is more reliable than the currently used flushing devices (it will not leak), is simple, more economical, and more water conserving (allowing one to choose the amount of water to use for flushing solid and liquid waste).
Combined optical coherence tomography and hyper-spectral imaging
NASA Astrophysics Data System (ADS)
Attendu, Xavier; Guay-Lord, Robin; Strupler, Mathias; Godbout, Nicolas; Boudoux, Caroline
2017-02-01
In this proceeding we demonstrate a system combining optical coherence tomography (OCT) and hyper-spectral imaging (HSI) into a single dual-clad fiber (DCF). Combining these modalities gives access to the sample morphology through OCT and to its molecular content through HSI. Both modalities have their illumination through the fiber core. The OCT is then collected through the core while the HSI is collected through the inner cladding of the DCF. A double-clad fiber coupler (DCFC) is used to address both channels separately. A scanning spectral filter was developed to successively inject narrow spectral bands of visible light into the fiber core and sweep across the entire visible spectrum. This allows for rapid HSI acquisition and high miniaturization potential.
NASA Astrophysics Data System (ADS)
Liang, Shanshan; Saidi, Arya; Jing, Joe; Liu, Gangjun; Li, Jiawen; Zhang, Jun; Sun, Changsen; Narula, Jagat; Chen, Zhongping
2012-07-01
We developed a multimodality fluorescence and optical coherence tomography probe based on a double-clad fiber (DCF) combiner. The probe is composed of a DCF combiner, grin lens, and micromotor in the distal end. An integrated swept-source optical coherence tomography and fluorescence intensity imaging system was developed based on the combined probe for the early diagnoses of atherosclerosis. This system is capable of real-time data acquisition and processing as well as image display. For fluorescence imaging, the inflammation of atherosclerosis and necrotic core formed with the annexin V-conjugated Cy5.5 were imaged. Ex vivo imaging of New Zealand white rabbit arteries demonstrated the capability of the combined system.
Distributed-current-feed and distributed-energy-store railguns
NASA Astrophysics Data System (ADS)
Holland, L. D.
1984-03-01
In connection with advances in railgun technology evolution toward the development of systems for specific applications, investigations are being conducted regarding a wide variety of power supply and railgun systems. The present study is concerned with the development of the distributed railguns and the introduction of a new type of railgun system specifically designed for applications requiring long accelerators. It is found that the distributed railguns offer a solution to the limits on performance of the breech-fed railguns as the length of the rails becomes large. Attention is given to the pulse-forming network and breech-fed railgun, the breech-fed railgun with parallel pulse-forming network, a distributed-energy-store railgun, a distributed-current-feed (DCF) railgun, and a DCF railgun launcher.
Wind-tunnel investigation of a flush airdata system at Mach numbers from 0.7 to 1.4
NASA Technical Reports Server (NTRS)
Larson, Terry J.; Moes, Timothy R.; Siemers, Paul M., III
1990-01-01
Flush pressure orifices installed on the nose section of a 1/7-scale model of the F-14 airplane were evaluated for use as a flush airdata system (FADS). Wing-tunnel tests were conducted in the 11- by 11-ft Unitary Wind Tunnel at NASA Ames Research Center. A full-scale FADS of the same configuration was previously tested using an F-14 aircraft at the Dryden Flight Research Facility of NASA Ames Research Center (Ames-Dryden). These tests, which were published, are part of a NASA program to assess accuracies of FADS for use on aircraft. The test program also provides data to validate algorithms for the shuttle entry airdata system developed at the NASA Langley Research Center. The wind-tunnel test Mach numbers were 0.73, 0.90, 1.05, 1.20, and 1.39. Angles of attack were varied in 2 deg increments from -4 deg to 20 deg. Sideslip angles were varied in 4 deg increments from -8 deg to 8 deg. Airdata parameters were evaluated for determination of free-stream values of stagnation pressure, static pressure, angle of attack, angle of sideslip, and Mach number. These parameters are, in most cases, the same as the parameters investigated in the flight test program. The basic FADS wind-tunnel data are presented in tabular form. A discussion of the more accurate parameters is included.
The educational potential of alcohol-related flushing among Chinese young people
Shell, Duane F.; Huang, Zhaoqing; Qian, Ling
2015-01-01
Aim: This paper describes Chinese university students' understanding of the meaning of the alcohol-related flushing response and how they reacted to their own and someone else's flushing in a group drinking situation. Method: The researcher surveyed 530 Chinese university students about their understanding of flushing and their perception of how people respond to a person who visibly flushes while drinking alcohol. Findings: Most students did not know about the physiological cause of flushing. There were significant gender differences in both reactions to and perception of responses to a person who flushes. There was no direct relationship between flushing and drinking behaviour. Conclusions: This description of flushing behaviour and responses to a flushing person is discussed in terms of educational opportunities to change behaviours that could reduce the cancer related risks of this visibly at-risk group. PMID:25983401
Failure detection and fault management techniques for flush airdata sensing systems
NASA Technical Reports Server (NTRS)
Whitmore, Stephen A.; Moes, Timothy R.; Leondes, Cornelius T.
1992-01-01
Methods based on chi-squared analysis are presented for detecting system and individual-port failures in the high-angle-of-attack flush airdata sensing system on the NASA F-18 High Alpha Research Vehicle. The HI-FADS hardware is introduced, and the aerodynamic model describes measured pressure in terms of dynamic pressure, angle of attack, angle of sideslip, and static pressure. Chi-squared analysis is described in the presentation of the concept for failure detection and fault management which includes nominal, iteration, and fault-management modes. A matrix of pressure orifices arranged in concentric circles on the nose of the aircraft indicate the parameters which are applied to the regression algorithms. The sensing techniques are applied to the F-18 flight data, and two examples are given of the computed angle-of-attack time histories. The failure-detection and fault-management techniques permit the matrix to be multiply redundant, and the chi-squared analysis is shown to be useful in the detection of failures.
Holm, Anna-Clara Spetz; Thorell, Lars-Håkan; Theodorsson, Elvar; Hammar, Mats
2012-01-01
Calcitonin gene-related peptide (CGRP) seems to be involved in hot flushes in women and in castrated men. Therefore, we studied whether the plasma concentrations of CGRP changed during flushes in a group of healthy aging men. Twelve men (49-71 years) with no history of current or former prostate cancer or hormonal treatment reporting ≥ 20 flushes/week were investigated. Blood samples were drawn during and between flushes for analysis of CGRP and also androgen concentrations, that is, testosterone and bioavailable testosterone were analysed. Skin temperature and skin conductance were monitored. Thirty-five flushes were reported by 10 men. The plasma concentrations of CGRP did not increase during flushes. No significant change in skin temperature or conductance was found. CGRP is probably not involved in the mechanisms of flushes in healthy aging men. Therefore, flushes in aging healthy men seem to be different from flushes in men and women deprived of sex steroids where CGRP increases during flushes.
33 CFR 162.20 - Flushing Bay near La Guardia Airport, Flushing, N.Y.; restricted area.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Flushing Bay near La Guardia Airport, Flushing, N.Y.; restricted area. 162.20 Section 162.20 Navigation and Navigable Waters COAST... NAVIGATION REGULATIONS § 162.20 Flushing Bay near La Guardia Airport, Flushing, N.Y.; restricted area. (a...
Sloboda, Darcée D.
2013-01-01
Skeletal muscles can be injured by lengthening contractions, when the muscles are stretched while activated. Lengthening contractions produce structural damage that leads to the degeneration and regeneration of damaged muscle fibers by mechanisms that have not been fully elucidated. Reactive oxygen species (ROS) generated at the time of injury may initiate degenerative or regenerative processes. In the present study we hypothesized that lengthening contractions that damage the muscle would generate more ROS than isometric contractions that do not cause damage. To test our hypothesis, we subjected muscles of mice to lengthening contractions or isometric contractions and simultaneously monitored intracellular ROS generation with the fluorescent indicator 5-(and-6)-chloromethyl-2′,7′-dichlorodihydrofluorescein (CM-DCFH), which is oxidized by ROS to form the fluorescent product CM-DCF. We found that CM-DCF fluorescence was not different during or shortly after lengthening contractions compared with isometric controls, regardless of the amount of stretch and damage that occurred during the lengthening contractions. The only exception was that after severe stretches, the increase in CM-DCF fluorescence was impaired. We conclude that lengthening contractions that damage the muscle do not generate more ROS than isometric contractions that do not cause damage. The implication is that ROS generated at the time of injury are not the initiating signals for subsequent degenerative or regenerative processes. PMID:23948772
Sloboda, Darcée D; Brooks, Susan V
2013-10-01
Skeletal muscles can be injured by lengthening contractions, when the muscles are stretched while activated. Lengthening contractions produce structural damage that leads to the degeneration and regeneration of damaged muscle fibers by mechanisms that have not been fully elucidated. Reactive oxygen species (ROS) generated at the time of injury may initiate degenerative or regenerative processes. In the present study we hypothesized that lengthening contractions that damage the muscle would generate more ROS than isometric contractions that do not cause damage. To test our hypothesis, we subjected muscles of mice to lengthening contractions or isometric contractions and simultaneously monitored intracellular ROS generation with the fluorescent indicator 5-(and-6)-chloromethyl-2',7'-dichlorodihydrofluorescein (CM-DCFH), which is oxidized by ROS to form the fluorescent product CM-DCF. We found that CM-DCF fluorescence was not different during or shortly after lengthening contractions compared with isometric controls, regardless of the amount of stretch and damage that occurred during the lengthening contractions. The only exception was that after severe stretches, the increase in CM-DCF fluorescence was impaired. We conclude that lengthening contractions that damage the muscle do not generate more ROS than isometric contractions that do not cause damage. The implication is that ROS generated at the time of injury are not the initiating signals for subsequent degenerative or regenerative processes.
Using APV (adjusted present value): a better tool for valuing operations.
Luehrman, T A
1997-01-01
Anyone who learned valuation techniques more than a few years ago is probably due for a refresher course. For the past 25 years, managers have been taught that the best practice for valuing assets-that is, an existing business, factory, product line, or market position-is to use a discounted-cash-flow (DCF) methodology. That is still true. But the particular version of DCF that has been accepted as the standard-using the weighted-average cost of capital (WACC)-is now obsolete. Today's better alternative, adjusted present value (APV), is especially versatile and reliable. It will likely replace WACC as the DCF methodology of choice among generalists. Like WACC, APV is used to value operations, or assets-in-place-that is, any existing asset that will generate a stream of future cash flows. Timothy Luehrman explains APV and walks readers through a case example designed to teach them how to use it. He argues that APV always works when WACC does-and sometimes when WACC doesn't, because it requires fewer restrictive assumptions. And APV is less prone to yield serious errors than WACC is. But, most important, general managers will find that APV's power lies in the managerially relevant information it provides. APV can help managers analyze not only how much an asset is worth but also where the value comes from.
Hormonal control of second flushing in Douglas-fir shoots.
Morris Cline; Mark Yoders; Dipti Desai; Constance Harrington; William Carlson
2006-01-01
Spring-flushing, over-wintered buds of Douglas-fir (Pseudotsuga menziesii (Mirb.) Franco) produce new buds that may follow various developmental pathways. These include second flushing in early summer or dormancy before flushing during the following spring. Second flushing usually entails an initial release of apical dominance as some of the...
Yan, Xiulan; Liu, Qiuxin; Wang, Jianyi; Liao, Xiaoyong
2017-07-01
Phytoremediation and soil washing are both potentially useful for remediating arsenic (As)-contaminated soils. We evaluated the effectiveness of a combined process coupling phytoremediation and in situ soil flushing for removal of As in contaminated soil through a pilot study. The results showed that growing Pteris vittata L. (P.v.) accompanied by soil flushing of phosphate (P.v./Flushing treatment) could significantly decrease the total As concentration of soil over a 37day flushing period compared with the single flushing (Flushing treatment). The P.v./Flushing treatment removed 54.04% of soil As from contaminated soil compared to 47.16% in Flushing treatment, suggesting that the growth of P. vittata was beneficial for promoting the removal efficiency. We analyzed the As fractionation in soil and As concentration in soil solution to reveal the mechanism behind this combined process. Results showed that comparing with the control treatment, the percent of labile arsenate fraction significantly increased by 17% under P.v./Flushing treatment. As concentration in soil solution remained a high lever during the middle and later periods (51.26-56.22mg/L), which was significantly higher than the Flushing treatment. Although soil flushing of phosphate for more than a month, P. vittata still had good accumulation and transfer capacity of As of the soil. The results of the research revealed that combination of phytoremediation and in situ soil flushing is available to remediate As-contaminated soils. Copyright © 2016. Published by Elsevier B.V.
A novel model for NSAID induced gastroenteropathy in rats.
Singh, Devendra Pratap; Borse, Swapnil P; Nivsarkar, Manish
2016-01-01
Progress in management of Nonsteroidal anti-inflammatory drug (NSAID) induced gastrointestinal toxicity requires the availability of appropriate experimental animal models that are as close to humans as feasible. Our objective was to develop a rat model for NSAID-induced gastroenteropathy and also to simulate the common clinical scenario of co-administration of NSAID and proton pump inhibitor (PPI) to explore if PPI contribute to exacerbation of NSAID-enteropathy. Rats were treated twice daily with pantoprazole sodium (PTZ; 10mg/kg peroral) or vehicle for a total of 10days. In some experiments, Diclofenac sodium (DCF; 9mg/kg) or vehicle was administered orally twice daily for the final 5days of PTZ/vehicle administration. After the last dose on 9th day, rats in all the groups were fasted but water was provided ad libitum. 12h after the last dose on 10th day, rats in all the groups were euthanized and their gastrointestinal tracts were assessed for haemorrhagic lesions, lipid peroxidation, intestinal permeability and gastrointestinal luminal pH alterations. Changes in haemoglobin, haematocrit and serum levels of albumin, total protein, ALT and bilirubin were calculated. The macroscopic and histological evidence suggested that administration of DCF resulted in significant gastroenteropathic damage and co-administration of PTZ resulted in significant exacerbation of NSAID enteropathy, while attenuation of NSAID induced gastropathy was observed. Our results were further supported by the significant decrease in haemoglobin and haematocrit levels and serum levels of albumin and total proteins, an increase in oxidative stress and intestinal permeability with the use of DCF either alone or in combination with PTZ. This model was developed to simulate the human clinical situation during NSAID therapy and indeed the present DCF regimen caused both gastric and small bowel alterations, such as multiple erosive lesions, together with a decrease in haemoglobin, haematocrit, serum albumin, serum total protein levels and IP alteration, known to occur in patients receiving NSAIDs. Additionally, this paper provides yet another evidence for PPI induced exacerbation of NSAID enteropathy. Copyright © 2015 Elsevier Inc. All rights reserved.
Franco, A; Willems, G; Souza, P H C; Tanaka, O M; Coucke, W; Thevissen, P
2017-04-01
Dental uniqueness can be proven if no perfect match in pair-wise morphological comparisons of human dentitions is detected. Establishing these comparisons in a worldwide random population is practically unfeasible due to the need for a large and representative sample size. Sample stratification is an option to reduce sample size. The present study investigated the uniqueness of the human dentition in randomly selected subjects (Group 1), orthodontically treated patients (Group 2), twins (Group 3), and orthodontically treated twins (Group 4) in comparison with a threshold control sample of identical dentitions (Group 5). The samples consisted of digital cast files (DCF) obtained through extraoral 3D scanning. A total of 2.013 pair-wise morphological comparisons were performed (Group 1 n=110, Group 2 n=1.711, Group 3 n=172, Group 4 n=10, Group 5 n=10) with Geomagic Studio ® (3D Systems ® , Rock Hill, SC, USA) software package. Comparisons within groups were performed quantifying the morphological differences between DCF in Euclidean distances. Comparisons between groups were established applying One-way ANOVA. To ensure fair comparisons a post-hoc Power Analysis was performed. ROC analysis was applied to distinguish unique from non-unique dentures. Identical DCF were not detected within the experimental groups (from 1 to 4). The most similar DCF had Euclidian distance of 5.19mm in Group 1, 2.06mm in Group 2, 2.03mm in Group 3, and 1.88mm in Group 4. Groups 2 and 3 were statistically different from Group 5 (p<0.05). Statistically significant difference between Group 4 and 5 revealed to be possible including more pair-wise comparisons in both groups. The ROC analysis revealed sensitivity rate of 80% and specificity between 66.7% and 81.6%. Evidence to sustain the uniqueness of the human dentition in random and stratified populations was observed in the present study. Further studies testing the influence of the quantity of tooth material on morphological difference between dentitions and its impact on uniqueness remain necessary. Copyright © 2017 Elsevier B.V. All rights reserved.
Piccirillo, Germano; Bochicchio, Brigida; Pepe, Antonietta; Schenke-Layland, Katja; Hinderer, Svenja
2017-04-01
Actinic Keratosis' (AKs) are small skin lesions that are related to a prolonged sun-damage, which can develop into invasive squamous cell carcinoma (SCC) when left untreated. Effective, specific and well tolerable therapies to cure AKs are still of great interest. Diclofenac (DCF) is the current gold standard for the local treatment of AKs in terms of costs, effectiveness, side effects and tolerability. In this work, an electrospun polylactic acid (PLA) scaffold loaded with a synthetic DCF prodrug was developed and characterized. Specifically, the prodrug was successfully synthetized by binding DCF to a glycine residue via solid phase peptide synthesis (SPPS) and then incorporated in an electrospun PLA scaffold. The drug encapsulation was verified using multiphoton microscopy (MPM) and its scaffold release was spectrophotometrically monitored and confirmed with MPM. The scaffold was further characterized with scanning electron microscopy (SEM), tensile testing and contact angle measurements. Its biocompatibility was verified by performing a cell proliferation assay and compared to PLA scaffolds containing the same amount of DCF sodium salt (DCFONa). Finally, the effect of the electrospun scaffolds on human dermal fibroblasts (HDFs) morphology and metabolism was investigated by combining MPM with fluorescence lifetime imaging microscopy (FLIM). The obtained results suggest that the obtained scaffold could be suitable for the controlled and targeted delivery of the synthesized prodrug for the treatment of AKs. Electrospun scaffolds are of growing interest as materials for a controlled drug delivery. In this work, an electrospun polylactic acid scaffold containing a synthetically obtained Diclofenac prodrug is proposed as a novel substrate for the topical treatment of actinic keratosis. A controlled drug delivery targeted to the area of interest could enhance the efficacy of the therapy and favor the healing process. The prodrug was synthesized via solid phase, employing a clean and versatile approach to obtain Diclofenac derivatives. Here, we used multiphoton microscopy to image drug encapsulation within the fibrous scaffold and fluorescence lifetime imaging microscopy to investigate Diclofenac effects and potential mechanisms of action. Copyright © 2016 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
Ohara, Yoshiko; Toyonaga, Takashi; Hoshi, Namiko; Tanaka, Shinwa; Baba, Shinichi; Takihara, Hiroshi; Kawara, Fumiaki; Ishida, Tsukasa; Morita, Yoshinori; Umegaki, Eiji; Azuma, Takeshi
2017-03-07
To investigated the usefulness of a novel slim type ball-tipped FlushKnife (FlushKnife-BTS) over ball-tipped FlushKnife (FlushKnife-BT) in functional experiments and clinical practice. In order to evaluate the functionality of FlushKnife-BTS, water aspiration speed, resistance to knife insertion through the scope, and waterjet flushing speed were compared between FlushKnife-BTS and BT. In clinical practice, esophageal endoscopic submucosal dissection (ESD) performed using FlushKnife-BTS or BT by an experienced endoscopist between October 2015 and January 2016 were retrospectively reviewed. The treatment speed and frequency of removing and reinserting the knife to aspirate fluid and air during ESD sessions were analyzed. Functional experiments revealed that water aspiration speed by the endoscope equipped with a 2.8-mm working channel with FlushKnife-BTS was 7.7-fold faster than that with conventional FlushKnife-BT. Resistance to knife insertion inside the scope with a 2.8-mm working channel was reduced by 40% with FlushKnife-BTS. The waterjet flushing speed was faster with the use of FlushKnife-BT. In clinical practice, a comparison of 6 and 7 ESD using FlushKnife-BT and BTS, respectively, revealed that the median treatment speed was 25.5 mm 2 /min (range 19.6-30.3) in the BT group and 44.2 mm 2 /min (range 15.5-55.4) in the BTS group ( P = 0.0633). However, the median treatment speed was significantly faster with FlushKnife-BTS when the resection size was larger than 1000 m 2 ( n = 4, median 24.2 mm 2 /min, range 19.6-27.7 vs n = 4, median 47.4 mm 2 /min, range 44.2-55.4, P = 0.0209). The frequency of knife replacement was less in the BTS group (median 1.76 times in one hour, range 0-5.45) than in the BT group (7.02 times in one hour, range 4.23-15) ( P = 0.0065). Our results indicate that FlushKnife-BTS enhances the performance of ESD, particularly for large lesions, by improving air and fluid aspiration and knife insertion during ESD and reducing the frequency of knife removal and reinsertion.
Ohara, Yoshiko; Toyonaga, Takashi; Hoshi, Namiko; Tanaka, Shinwa; Baba, Shinichi; Takihara, Hiroshi; Kawara, Fumiaki; Ishida, Tsukasa; Morita, Yoshinori; Umegaki, Eiji; Azuma, Takeshi
2017-01-01
AIM To investigated the usefulness of a novel slim type ball-tipped FlushKnife (FlushKnife-BTS) over ball-tipped FlushKnife (FlushKnife-BT) in functional experiments and clinical practice. METHODS In order to evaluate the functionality of FlushKnife-BTS, water aspiration speed, resistance to knife insertion through the scope, and waterjet flushing speed were compared between FlushKnife-BTS and BT. In clinical practice, esophageal endoscopic submucosal dissection (ESD) performed using FlushKnife-BTS or BT by an experienced endoscopist between October 2015 and January 2016 were retrospectively reviewed. The treatment speed and frequency of removing and reinserting the knife to aspirate fluid and air during ESD sessions were analyzed. RESULTS Functional experiments revealed that water aspiration speed by the endoscope equipped with a 2.8-mm working channel with FlushKnife-BTS was 7.7-fold faster than that with conventional FlushKnife-BT. Resistance to knife insertion inside the scope with a 2.8-mm working channel was reduced by 40% with FlushKnife-BTS. The waterjet flushing speed was faster with the use of FlushKnife-BT. In clinical practice, a comparison of 6 and 7 ESD using FlushKnife-BT and BTS, respectively, revealed that the median treatment speed was 25.5 mm2/min (range 19.6-30.3) in the BT group and 44.2 mm2/min (range 15.5-55.4) in the BTS group (P = 0.0633). However, the median treatment speed was significantly faster with FlushKnife-BTS when the resection size was larger than 1000 m2 (n = 4, median 24.2 mm2/min, range 19.6-27.7 vs n = 4, median 47.4 mm2/min, range 44.2-55.4, P = 0.0209). The frequency of knife replacement was less in the BTS group (median 1.76 times in one hour, range 0-5.45) than in the BT group (7.02 times in one hour, range 4.23-15) (P = 0.0065). CONCLUSION Our results indicate that FlushKnife-BTS enhances the performance of ESD, particularly for large lesions, by improving air and fluid aspiration and knife insertion during ESD and reducing the frequency of knife removal and reinsertion. PMID:28321167
NASA Astrophysics Data System (ADS)
Wang, Xingwei; Chen, Jiajun
2017-06-01
With an aim to investigate the influence of small-scale interlayer heterogeneity on DDT removal efficiency, batch test including surfactant-stabilized foam flushing and solution flushing were carried out. Two man-made heterogeneous patterns consisting of coarse and fine quartz sand were designed to reveal the influencing mechanism. Moreover, the removal mechanism and the corresponding contribution by foam flushing were quantitatively studied. Compared with surfactant solution flushing, the DDT removal efficiency by surfactant-stabilized foam flushing increased by 9.47% and 11.28% under heterogeneous patterns 1 and 2, respectively. The DDT removal contributions of improving sweep efficiency for heterogeneous patterns 1 and 2 by foam flushing were 40.82% and 45.98%, and the contribution of dissolving capacity were 59.18% and 54.02%, respectively. The dissolving capacity of DDT played a major role in DDT removal efficiency by foam flushing under laboratory conditions. And the DDT removal contribution of significant improving sweep efficiency was higher than that of removal decline caused by weak solubilizing ability of foam film compared with solution flushing. The obtained results indicated that the difference of DDT removal efficiency by foam flushing was decreased under two different heterogeneous patterns with the increase of the contribution of improving foam flushing sweep efficiency. It suggested that foam flushing can reduce the disturbance from interlayer heterogeneity in remediating DDT contaminated heterogeneous medium.
33 CFR 162.20 - Flushing Bay near La Guardia Airport, Flushing, N.Y.; restricted area.
Code of Federal Regulations, 2013 CFR
2013-07-01
... Airport, Flushing, N.Y.; restricted area. 162.20 Section 162.20 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PORTS AND WATERWAYS SAFETY INLAND WATERWAYS NAVIGATION REGULATIONS § 162.20 Flushing Bay near La Guardia Airport, Flushing, N.Y.; restricted area. (a...
33 CFR 162.20 - Flushing Bay near La Guardia Airport, Flushing, N.Y.; restricted area.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Airport, Flushing, N.Y.; restricted area. 162.20 Section 162.20 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PORTS AND WATERWAYS SAFETY INLAND WATERWAYS NAVIGATION REGULATIONS § 162.20 Flushing Bay near La Guardia Airport, Flushing, N.Y.; restricted area. (a...
A network architecture for precision formation flying using the IEEE 802.11 MAC Protocol
NASA Technical Reports Server (NTRS)
Clare, Loren P.; Gao, Jay L.; Jennings, Esther H.; Okino, Clayton
2005-01-01
Precision Formation Flying missions involve the tracking and maintenance of spacecraft in a desired geometric formation. The strong coupling of spacecraft in formation flying control requires inter-spacecraft communication to exchange information. In this paper, we present a network architecture that supports PFF control, from the initial random deployment phase to the final formation. We show that a suitable MAC layer for the application protocol is IEEE's 802.11 MAC protocol. IEEE 802.11 MAC has two modes of operations: DCF and PCF. We show that DCF is suitable for the initial deployment phase while switching to PCF when the spacecraft are in formation improves jitter and throughput. We also consider the effect of routing on protocol performance and suggest when it is profitable to turn off route discovery to achieve better network performance.
Measurement of creatinine in human plasma using a functional porous polymer structure sensing motif
Nanda, Sitansu Sekhar; An, Seong Soo A; Yi, Dong Kee
2015-01-01
In this study, a new method for detecting creatinine was developed. This novel sensor comprised of two ionic liquids, poly-lactic-co-glycolic acid (PLGA) and 1-butyl-3-methylimidazolium (BMIM) chloride, in the presence of 2′,7′-dichlorofluorescein diacetate (DCFH-DA). PLGA and BMIM chloride formed a functional porous polymer structure (FPPS)-like structure. Creatinine within the FPPS rapidly hydrolyzed and released OH−, which in turn converted DCFH-DA to DCFH, developing an intense green color or green fluorescence. The conversion of DCFH to DCF+ resulted in swelling of FPPS and increased solubility. This DCF+-based sensor could detect creatinine levels with detection limit of 5 µM and also measure the creatinine in blood. This novel method could be used in diagnostic applications for monitoring individuals with renal dysfunction. PMID:26347475
Boly, Rainatou; Franck, Thierry; Kohnen, Stephan; Lompo, Marius; Guissou, Innocent Pierre; Dubois, Jacques; Serteyn, Didier; Mouithys-Mickalad, Ange
2015-01-01
The ethyl acetate and n-butanolic subfractions of Agelanthus dodoneifolius were investigated for their antioxidant and antimyeloperoxidase (MPO) activities. The reactive oxygen species (ROS) generation was assessed by lucigenin-enhanced chemiluminescence (CL) and dichlorofluorescein- (DCF-) induced fluorescence techniques from phorbol myristate acetate- (PMA-) stimulated equine neutrophils and human myeloid cell line HL-60, respectively. In parallel, the effects of the tested subfractions were evaluated on the total MPO release by stimulated neutrophils and on the specific MPO activity by means of immunological assays. The results showed the potent activity of the butanolic subfraction, at least in respect of the chemiluminescence test (IC50 = 0.3 ± 0.1 µg/mL) and the ELISA and SIEFED assays (IC50 = 2.8 ± 1.2 µg/mL and 1.3 ± 1.0 µg/mL), respectively. However, the ethyl acetate subfraction was found to be the most potent in the DCF assay as at the highest concentration, DCF fluorescence intensity decreases of about 50%. Moreover, we demonstrated that the ethyl acetate subfraction was rich in catechin (16.51%) while it was not easy to identify the main compounds in the butanolic subfraction using the UPLC-MS/MS technique. Nevertheless, taken together, our results provide evidence that Agelanthus dodoneifolius subfractions may represent potential sources of natural antioxidants and of antimyeloperoxidase compounds. PMID:25821497
Saitta, Kyle S.; Zhang, Carmen; Lee, Kang Kwang; Fujimoto, Kazunori; Redinbo, Matthew R.; Boelsterli, Urs A.
2014-01-01
We have previously demonstrated that a small molecule inhibitor of bacterial β-glucuronidase (Inh-1; [1-((6,8-dimethyl-2-oxo-1,2-dihydroquinolin-3-yl)-3-(4-ethoxyphenyl)-1-(2-hydroxyethyl)thiourea]) protected mice against diclofenac (DCF)-induced enteropathy. Here we report that Inh-1 was equally protective against small intestinal injury induced by other carboxylic acid-containing non-steroidal anti-inflammatory drugs (NSAIDs), indomethacin (10 mg/kg, ip) and ketoprofen (100 mg/kg, ip).Inh-1 provided complete protection if given prior to DCF (60 mg/kg, ip), and partial protection if administered 3-h post-DCF, suggesting that the temporal window of mucosal protection can be extended for drugs undergoing extensive enterohepatic circulation.Pharmacokinetic analysis of Inh-1 revealed an absolute bioavailability (F) of 21% and a short t1/2 of <1 h. This low F was shown to be due to hepatic first-pass metabolism, as confirmed with the pan-CYP inhibitor, 1-aminobenzotriazole.Using the fluorescent probe 5 (and 6)-carboxy-2′,7′-dichlorofluorescein, we demonstrated that Inh-1 did not interfere with hepatobiliary export of glucuronides in gall bladder-cannulated mice.These data are compatible with the hypothesis that pharmacological inhibition of bacterial β-glucuronidase-mediated cleavage of NSAID glucuronides in the small intestinal lumen can protect against NSAID-induced enteropathy caused by locally high concentrations of NSAID aglycones. PMID:23829165
Yan, Hongyuan; Yang, Chen; Sun, Yunyun; Row, Kyung Ho
2014-09-26
A new type of ionic liquid molecularly imprinted polymers (IL-MIPs) synthesized by precipitation polymerization using 1-allyl-3-methylimidazolium bromide as an auxiliary solvent and α-chloro-dichlorodiphenyltrichloroethane (α-chloro-DDT) as the template was applied as a selective sorbent of minimized pipette tip-solid-phase extraction (PT-SPE) for rapid isolation and extraction of dicofol (DCF) from celery samples. The pretreatment procedure of celery samples involved only 2.0mg of IL-MIPs, 0.8 mL of acetonitrile-water (ACN-H2O; 1:1, v/v) (washing solvent), and 1.0 mL of acetone-10% acetic acid (HOAc) (elution solvent). Compared with molecularly imprinted polymers (MIPs), ionic liquid-non-imprinted polymers (IL-NIPs) and conventional sorbents such as C18, Si, NH2, and Al2O3-N, IL-MIPs showed higher adsorption and purification capacity to DCF in aqueous solution. Good linearity for DCF was observed in the range from 2.3 to 232.5 ng g(-1) (r(2)=0.9995). The average recoveries at three spiking levels ranged from 86.6% to 101.9% with relative standard deviations (RSDs) of ≤ 6.5% (n=3). The presented IL-MIPs-PT-SPE-GC/ECD method combines the advantages of MIPs, IL, and PT-SPE, and can be used in aqueous conditions with high affinity and selectivity to analytes of complex samples. Copyright © 2014 Elsevier B.V. All rights reserved.
Zhou, Zhengwei; Jiang, Jia-Qian
2015-03-15
The performance of ferrate(VI) in treating sulfamethoxazole (SMX), diclofenac (DCF), carbamazepine (CBZ) and bezafibrate (BZF) in test solutions containing the four compounds was investigated. A series of jar-test experiments was performed on a bench-scale at pH 6-9 and at a ferrate(VI) dose of 1-5 mg Fe/L. The results suggested that ferrate(VI) can effectively remove SMX, DCF and CBZ from the test solutions, with greater than 80% removal under optimum conditions. However, the removal efficiency of BZF was very low, less than 25% under the studied conditions. Increasing the dose of ferrate(VI) improved the treatment performance, while the influence of solution pH on ferrate(VI) performance varied among the different target compounds. Ferrate(VI) demonstrated the highest reactivity with SMX at pH 8 and pH 9 (20 °C), with apparent second-order rate constants of 360±17 M(-1) s(-1) and 1.26±0.02 M(-1) s(-1), respectively. However, BZF showed the lowest removal by ferrate(VI) with the smallest rate constants (less than 0.5 M(-1) s(-1)) at pH 8 and pH 9. Furthermore, a number of oxidation products (OPs) of SMX, DCF and CBZ during ferrate(VI) oxidation were detected by liquid chromatography and mass spectrometry (LC-MS), and their degradation pathways were tentatively proposed. No OPs of BZF were detected during ferrate(VI) oxidation. Copyright © 2014 Elsevier B.V. All rights reserved.
What's it worth? A general manager's guide to valuation.
Luehrman, T A
1997-01-01
Behind every major resource-allocation decision a company makes lies some calculation of what that move is worth. So it is not surprising that valuation is the financial analytical skill general managers want to learn more than any other. Managers whose formal training is more than a few years old, however, are likely to have learned approaches that are becoming obsolete. What do generalists need in an updated valuation tool kit? In the 1970s, discounted-cash-flow analysis (DCF) emerged as best practice for valuing corporate assets. And one version of DCF-using the weighted-average cost of capital (WACC)-became the standard. Over the years, WACC has been used by most companies as a one-size-fits-all valuation tool. Today the WACC standard is insufficient. Improvements in computers and new theoretical insights have given rise to tools that outperform WACC in the three basic types of valuation problems managers face. Timothy Luehrman presents an overview of the three tools, explaining how they work and when to use them. For valuing operations, the DCF methodology of adjusted present value allows managers to break a problem into pieces that make managerial sense. For valuing opportunities, option pricing captures the contingent nature of investments in areas such as R&D and marketing. And for valuing ownership claims, the tool of equity cash flows helps managers value their company's stake in a joint venture, a strategic alliance, or an investment that uses project financing.
Islas-Flores, Hariz; Manuel Gómez-Oliván, Leobardo; Galar-Martínez, Marcela; Michelle Sánchez-Ocampo, Esmeralda; SanJuan-Reyes, Nely; Ortíz-Reynoso, Mariana; Dublán-García, Octavio
2017-05-01
Thirty million people worldwide consume each day nonsteroidal anti-inflammatory drugs (NSAIDs), a heterogeneous group of pharmaceuticals used for its analgesic, antipyretic, and anti-inflammatory properties. Recent studies report high NSAID concentrations in wastewater treatment plant effluents, in surface, ground, and drinking water, and in sediments. NSAIDs are also known to induce toxicity on aquatic organisms. However, toxicity in natural ecosystems is not usually the result of exposure to a single substance but to a mixture of toxic agents, yet only a few studies have evaluated the toxicity of mixtures. The aim of this study was to evaluate the toxicity induced by diclofenac (DCF), ibuprofen (IBP), and their mixture on a species of commercial interest, the common carp Cyprinus carpio. The median lethal concentration of IBP and DCF was determined, and oxidative stress was evaluated using the following biomarkers: lipid peroxidation and activity of the antioxidant enzymes superoxide dismutase, catalase and glutathione peroxidase. Cyto-genotoxicity was evaluated by micronucleus test, comet assay, and the specific activity of caspase-3. Results show that DCF, IBP, and a mixture of these pharmaceuticals induced free radical production, oxidative stress and cyto-genotoxicity in tissues of C. carpio. However, a greater effect was elicited by the mixture than by either pharmaceutical alone in some biomarkers evaluated, particularly in gill. © 2016 Wiley Periodicals, Inc. Environ Toxicol 32: 1637-1650, 2017. © 2017 Wiley Periodicals, Inc.
Morphology and Length Correlated in Terminal Flushes of Longleaf Pine Saplings
R.M. Allen; N.M. Scarbrough
1970-01-01
In longleafpine (Pinuspalustris Mill.) saplings growing in southern Mississippi the length of the first or spring flush was significantly correlated with that of the second flush; the correlation of length between flushes two and three was also statistically significant. The correlations were due more to similarities in internode elongation than to node number. Flush...
Wang, Xingwei; Chen, Jiajun
2017-06-01
With an aim to investigate the influence of small-scale interlayer heterogeneity on DDT removal efficiency, batch test including surfactant-stabilized foam flushing and solution flushing were carried out. Two man-made heterogeneous patterns consisting of coarse and fine quartz sand were designed to reveal the influencing mechanism. Moreover, the removal mechanism and the corresponding contribution by foam flushing were quantitatively studied. Compared with surfactant solution flushing, the DDT removal efficiency by surfactant-stabilized foam flushing increased by 9.47% and 11.28% under heterogeneous patterns 1 and 2, respectively. The DDT removal contributions of improving sweep efficiency for heterogeneous patterns 1 and 2 by foam flushing were 40.82% and 45.98%, and the contribution of dissolving capacity were 59.18% and 54.02%, respectively. The dissolving capacity of DDT played a major role in DDT removal efficiency by foam flushing under laboratory conditions. And the DDT removal contribution of significant improving sweep efficiency was higher than that of removal decline caused by weak solubilizing ability of foam film compared with solution flushing. The obtained results indicated that the difference of DDT removal efficiency by foam flushing was decreased under two different heterogeneous patterns with the increase of the contribution of improving foam flushing sweep efficiency. It suggested that foam flushing can reduce the disturbance from interlayer heterogeneity in remediating DDT contaminated heterogeneous medium. Copyright © 2017 Elsevier B.V. All rights reserved.
Hot flushes, coronary heart disease, and hormone therapy in postmenopausal women
Huang, Alison J.; Sawaya, George F.; Vittinghoff, Eric; Lin, Feng; Grady, Deborah
2010-01-01
Objective The aim of this study was to examine interactions between hot flushes, estrogen plus progestogen therapy (EPT), and coronary heart disease (CHD) events in postmenopausal women with CHD. Methods We analyzed data from the Heart and Estrogen/Progestin Replacement Study, a randomized, placebo-controlled trial of 0.625 mg conjugated equine estrogens plus 2.5 mg medroxyprogesterone acetate in 2,763 postmenopausal women with CHD. Hot flushes were assessed at baseline using self-administered questionnaires; women reporting bothersome hot flushes “some” to ”all” of the time were considered to have clinically significant flushing. Cox regression models were used to examine the effect of EPT on risk of CHD events among women with and without significant flushing at baseline. Results The mean age of participants was 66.7 ± 6.8 years, and 89% (n = 2,448) were white. Sixteen percent (n = 434) of participants reported clinically significant hot flushes at baseline. Among women with baseline flushing, EPT increased risk of CHD events nine-fold in the first year compared with placebo (hazard ratio = 9.01; 95% CI, 1.15-70.35); among women without baseline flushing, treatment did not significantly affect CHD event risk in the first year (hazard ratio = 1.32; 95% CI, 0.86-2.03; P = 0.07 for interaction of hot flushes with treatment). The trend toward differential effects of EPT on risk for CHD among women with and without baseline flushing did not persist after the first year of treatment. Conclusions Among older postmenopausal women with CHD, EPT may increase risk of CHD events substantially in the first year of treatment among women with clinically significant hot flushes but not among those without hot flushes. PMID:19325499
Influence of headspace flushing on methane production in Biochemical Methane Potential (BMP) tests.
Koch, Konrad; Bajón Fernández, Yadira; Drewes, Jörg E
2015-06-01
The influence of headspace flushing on the specific methane (CH4) production of blank samples with just inoculum in Biochemical Methane Potential (BMP) tests was studied. The three most common ways were applied: flushing with nitrogen (N2) gas, flushing with a mixture of N2 and CO2 (80/20 v/v), and no flushing. The results revealed that removing the oxygen is crucial to avoid aerobic respiration, which caused both hindered activity of methanogens and loss of methane potential. Furthermore it was demonstrated that 20% of CO2 in the flush gas increased significantly the methane production by over 20% compared to the flushing with pure N2. In order to mimic the same headspace conditions as in full-scale treatment plants, using a flush gas with a similar CO2 concentration as the expected biogas is suggested. Copyright © 2015 Elsevier Ltd. All rights reserved.
Failure detection and fault management techniques for flush airdata sensing systems
NASA Technical Reports Server (NTRS)
Whitmore, Stephen A.; Moes, Timothy R.; Leondes, Cornelius T.
1992-01-01
A high-angle-of-attack flush airdata sensing system was installed and flight tested on the F-18 High Alpha Research Vehicle at NASA-Dryden. This system uses a matrix of pressure orifices arranged in concentric circles on the nose of the vehicle to determine angles of attack, angles of sideslip, dynamic pressure, and static pressure as well as other airdata parameters. Results presented use an arrangement of 11 symmetrically distributed ports on the aircraft nose. Experience with this sensing system data indicates that the primary concern for real-time implementation is the detection and management of overall system and individual pressure sensor failures. The multiple port sensing system is more tolerant to small disturbances in the measured pressure data than conventional probe-based intrusive airdata systems. However, under adverse circumstances, large undetected failures in individual pressure ports can result in algorithm divergence and catastrophic failure of the entire system. How system and individual port failures may be detected using chi sq. analysis is shown. Once identified, the effects of failures are eliminated using weighted least squares.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hanson, P.J.; Isebrands, J.G.; Dickson, R.E.
1988-03-01
Carbon dioxide exchange rates (CERs) of all leaves along the stem of northern red oak (Quercus rubra L.) seedlings (a leaf insertion gradient of profile) were determined at several stages of ontogeny. Seedlings were grown and measured under growth chamber conditions favorable for the production of multiple flushes of shoot growth. The CERs were measured with a portable closed-circuit CO{sub 2} analyzer at ambient photosynthetic photon flux densities and were determined for every leaf of each seedling. Carbon dioxide exchange rates per unit projected area of individual leaves (CERA) increased along leaf-maturation gradients in expanding flushes. After flush growth wasmore » completed, all leaves of a flush has similar CERA. However, because median flush leaves were the largest, they accounted for the greatest proportion of an expanded-flush's CER. First-flush leaves were the major contributors to total seedling CER through the second flush of growth-encompassing half of the period required to produce a three-flush oak seedling. This study's data, based on short-term CER measurements, showed ontogenetic pattern of CO{sub 2} exchange similar to those reported for northern red oak under steady state laboratory conditions.« less
Exercise training reduces the acute physiological severity of post‐menopausal hot flushes
Bailey, Tom G.; Cable, N. Timothy; Aziz, Nabil; Atkinson, Greg; Cuthbertson, Daniel J.; Low, David A.
2016-01-01
Key points A post‐menopausal hot flush consists of profuse physiological elevations in cutaneous vasodilatation and sweating that are accompanied by reduced brain blood flow. These responses can be used to objectively quantify hot flush severity.The impact of an exercise training intervention on the physiological responses occurring during a hot flush is currently unknown.In a preference‐controlled trial involving 21 post‐menopausal women, 16 weeks of supervised moderate intensity exercise training was found to improve cardiorespiratory fitness and attenuate cutaneous vasodilatation, sweating and the reductions in cerebral blood flow during a hot flush.It is concluded that the improvements in fitness that are mediated by 16 weeks of exercise training reduce the severity of physiological symptoms that occur during a post‐menopausal hot flush. Abstract A hot flush is characterised by feelings of intense heat, profuse elevations in cutaneous vasodilatation and sweating, and reduced brain blood flow. Exercise training reduces self‐reported hot flush severity, but underpinning physiological data are lacking. We hypothesised that exercise training attenuates the changes in cutaneous vasodilatation, sweat rate and cerebral blood flow during a hot flush. In a preference trial, 18 symptomatic post‐menopausal women underwent a passive heat stress to induce hot flushes at baseline and follow‐up. Fourteen participants opted for a 16 week moderate intensity supervised exercise intervention, while seven participants opted for control. Sweat rate, cutaneous vasodilatation, blood pressure, heart rate and middle cerebral artery velocity (MCAv) were measured during the hot flushes. Data were binned into eight equal segments, each representing 12.5% of hot flush duration. Weekly self‐reported frequency and severity of hot flushes were also recorded at baseline and follow‐up. Following training, mean hot flush sweat rate decreased by 0.04 mg cm2 min−1 at the chest (95% confidence interval 0.02–0.06, P = 0.01) and by 0.03 mg cm2 min−1 (0.02–0.05, P = 0.03) at the forearm, compared with negligible changes in control. Training also mediated reductions in cutaneous vasodilatation by 9% (6–12%) at the chest and by 7% (4–9%) at forearm (P ≤ 0.05). Training attenuated hot flush MCAv by 3.4 cm s−1 (0.7–5.1 cm s−1, P = 0.04) compared with negligible changes in control. Exercise training reduced the self‐reported severity of hot flushes by 109 arbitrary units (80–121, P < 0.001). These data indicate that exercise training leads to parallel reductions in hot flush severity and within‐flush changes in cutaneous vasodilatation, sweating and cerebral blood flow. PMID:26676059
Soy germ extract alleviates menopausal hot flushes: placebo-controlled double-blind trial.
Imhof, Martin; Gocan, Anca; Imhof, Marianne; Schmidt, Mathias
2018-05-30
A double-blind, placebo-controlled study was performed to assess the potency of a soy germ preparation for the alleviation of menopausal hot flushes. Caucasian women with at least seven hot flushes daily were treated with soy germ extract (100 mg isoflavone glycosides) daily or with placebo for 12 weeks, followed by 12 weeks of open treatment with soy. Outcome parameters were the number of hot flushes and the evaluation of the Greene Climacteric Scale. A total of 192 women were included. As the hot flush diaries from one study centre were lost, the assessment of hot flushes was based on 136 participants (soy: 54 women; placebo: 82 women). After 12 weeks, 180 women were available for the analysis of Greene Scale and safety (soy and placebo: each 90 women). Hot flushes were reduced by 43.3% (-3.5 hot flushes) with soy and by 30.8% with placebo (-2.6; p < 0.001). After the open treatment phase with soy, both original groups showed a reduction of 68% of hot flushes. A subgroup analysis showed better effects for soy when symptoms were classified as "severe" at baseline. After 12 weeks of double-blind treatment, there was an improvement from baseline values of 71 and 78% with soy with the items "hot flushes" and "sweating", compared with 24% for both items with placebo. Hormonal safety parameters remained uninfluenced. Soy germ extract with 100 mg of isoflavone glycosides was shown to modestly, but significantly reduce menopausal hot flushes.
NASA Astrophysics Data System (ADS)
Desjardins, Michèle; Gagnon, Louis; Gauthier, Claudine; Hoge, Rick D.; Dehaes, Mathieu; Desjardins-Crépeau, Laurence; Bherer, Louis; Lesage, Frédéric
2009-02-01
Biophysical models of hemodynamics provide a tool for quantitative multimodal brain imaging by allowing a deeper understanding of the interplay between neural activity and blood oxygenation, volume and flow responses to stimuli. Multicompartment dynamical models that describe the dynamics and interactions of the vascular and metabolic components of evoked hemodynamic responses have been developed in the literature. In this work, multimodal data using near-infrared spectroscopy (NIRS) and diffuse correlation flowmetry (DCF) is used to estimate total baseline hemoglobin concentration (HBT0) in 7 adult subjects. A validation of the model estimate and investigation of the partial volume effect is done by comparing with time-resolved spectroscopy (TRS) measures of absolute HBT0. Simultaneous NIRS and DCF measurements during hypercapnia are then performed, but are found to be hardly reproducible. The results raise questions about the feasibility of an all-optical model-based estimation of individual vascular properties.
Monteagudo, J M; El-Taliawy, H; Durán, A; Caro, G; Bester, K
2018-06-20
Degradation of a diclofenac aqueous solution was performed using persulfate anions activated by ultrasound. The objective of this study was to analyze different parameters affecting the diclofenac (DCF) removal reaction by the ultrasonic persulfate (US/PS) process and to evaluate the role played by various intermediate oxidative species such as hydroxyl- and sulfate radicals, superoxide radical anion or singlet oxygen in the removal process as well as to determine a possible reaction pathway. The effects of pH, initial persulfate anion concentration, ultrasonic amplitude and temperature on DCF degradation were examined. Sulfate and hydroxyl radicals were involved in the main reaction pathway of diclofenac. Diclofenac amide and three hydroxy-diclofenac isomers (3´-hydroxy diclofenac, 4´-hydroxy diclofenac and 5-hydroxy diclofenac) were identified as reaction intermediates. Copyright © 2018 Elsevier B.V. All rights reserved.
Eziefula, C U; Grunfeld, E A; Hunter, M S
2013-12-01
Hot flushes and night sweats are common amongst menopausal women, and psychological interventions for managing these symptoms have recently been developed for women. However, flushes in men with prostate cancer, which commonly occur following androgen deprivation therapy (ADT), remain under-researched. This study is a qualitative exploration of flush-related cognitive appraisals and behavioural reactions reported by a sample of these men. Semi-structured, in-depth interviews were conducted with 19 men who were experiencing flushes after receiving ADT for prostate cancer. Framework analysis was used to generate and categorise emergent themes and explore associations between themes. Five main cognitive appraisals included the following: changes in oneself, impact on masculinity, embarrassment/social-evaluative concerns, perceived control and acceptance/adjustment. There were men who held beliefs about the impact of flushes on their perceptions of traditional gender roles, who experienced shame and embarrassment due to concerns about the salience of flushes and perceptions by others and who experienced feelings of powerlessness over flushes. Powerlessness was associated with beliefs about the potentially fatal consequences of discontinuing treatment. Two other dominant themes included awareness/knowledge about flushes and management strategies. Experiences of flushes appeared to be influenced by upbringing and general experiences of prostate cancer and ADT. The range of men's appraisals of, and reactions to, flushes generated from this qualitative exploration were broadly similar to those of menopausal women but differed in terms of the influence of masculinity beliefs. These findings could be used to inform future research and psychological interventions in this under-researched field. Copyright © 2013 John Wiley & Sons, Ltd.
Effect of hypothermic pulmonary artery flushing on capillary filtration coefficient.
Andrade, R S; Wangensteen, O D; Jo, J K; Tsai, M Y; Bolman, R M
2000-07-27
We previously demonstrated that surfactant dilution and inhibition occur immediately after pulmonary artery flushing with hypothermic modified Euro-Collins solution. Consequently, we speculated that increased capillary permeability contributed to these surfactant changes. To test this hypothesis, we evaluated the effects of hypothermic pulmonary artery flushing on the pulmonary capillary filtration coefficient (Kfc), and additionally performed a biochemical analysis of surfactant. We used a murine isolated, perfused lung model to measure the pulmonary capillary filtration coefficient and hemodynamic parameters, to determine the wet to dry weight ratio, and to evaluate surfactant by biochemical analysis of lung lavage fluid. We defined three study groups. In group I (controls), we harvested lungs without hypothermic pulmonary artery flushing, and measured Kfc immediately. In group II (in situ flush), we harvested lungs after hypothermic pulmonary artery flushing with modified Euro-Collins solution, and then measured Kfc. Experiments in groups I and II were designed to evaluate persistent changes in Kfc after pulmonary artery flushing. In group III (ex vivo flush), we flushed lungs ex vivo to evaluate transient changes in Kfc during hypothermic pulmonary artery flushing. Groups I and II did not differ significantly in capillary filtration coefficient and hemodynamics. Group II showed significant alterations on biochemical surfactant analysis and a significant increase in wet-to-dry weight ratio, when compared with group I. In group III, we observed a significant transient increase in capillary filtration coefficient during pulmonary artery flushing. Hypothermic pulmonary artery flushing transiently increases the capillary filtration coefficient, leads to an increase in the wet to dry weight ratio, and induces biochemical surfactant changes. These findings could be explained by the effects of hypothermic modified Euro-Collins solution on pulmonary capillary permeability.
Sétamou, Mamoudou; Alabi, Olufemi J; Kunta, Madhurababu; Jifon, John L; da Graça, John V
2016-10-01
The Asian citrus psyllid preferentially feeds and exclusively reproduces on young, newly emerged flush shoots of citrus. Asian citrus psyllid nymphs feed and complete their life stages on these flush shoots. Recent studies conducted under greenhouse conditions have shown that the transmission rates of 'Candidatus Liberibacter asiaticus' (CLas), the putative causal agent of huanglongbing disease of citrus, are enhanced when flush shoots are present. However, it is unclear if CLas acquisition by migrant adult Asian citrus psyllids is similarly enhanced. To address this knowledge gap, cohorts of Asian citrus psyllid adults were allowed 1-wk acquisition access period (AAP) on flushing and nonflushing shoots of qPCR-tested symptomatic (CLas+) and asymptomatic (CLas-) 10-yr-old sweet orange trees under field conditions. After the AAP, they were tested for CLas by qPCR. Progeny Asian citrus psyllid adults that emerged 4 wk post-AAP were similarly retrieved and tested. Eighty percent of flushing and 30% of nonflushing CLas+ trees produced infective Asian citrus psyllid adults, indicating that flush shoots have greater potential to be inoculum sources for CLas acquisition. Concomitantly, 21.1% and 6.0% infective adults were retrieved, respectively, from flushing and nonflushing CLas+ trees, indicating that Asian citrus psyllid adults acquire CLas more efficiently from flush shoots relative to mature shoots. In addition, 12.1% of infective Asian citrus psyllid adult progeny were obtained from 70% of flushing CLas+ trees. Significantly lower mean Ct values were also obtained from infective adults retrieved from flushing relative to nonflushing trees. The results underscore the role of flush shoots in CLas acquisition and the need to protect citrus trees from Asian citrus psyllid infestations during flush cycles. © The Authors 2016. Published by Oxford University Press on behalf of Entomological Society of America. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Rastogi, Vaibhav; Singh, Devina; Mazza, Joseph J; Yang, Dennis; Parajuli, Dipendra; Yale, Steven H
2018-04-12
Flushing is the subjective sensation of warmth accompanied by visible cutaneous erythema occurring throughout the body with a predilection for the face, neck, pinnae, and upper trunk where the skin is thinnest and cutaneous vessels are superficially located and in greatest numbers. Flushing can be present in either a wet or dry form depending upon whether neural-mediated mechanisms are involved. Activation of the sympathetic nervous system results in wet flushing, accompanied by diaphoresis, due to concomitant stimulation of eccrine sweat glands. Wet flushing is caused by certain medications, panic disorder and paroxysmal extreme pain disorder (PEPD). Vasodilator mediated flushing due to the formation and release of a variety of biogenic amines, neuropeptides and phospholipid mediators such as histamine, serotonin and prostaglandins respectively, typically presents as dry flushing where sweating is characteristically absent. Flushing occurring with neuroendocrine tumors accompanied by gastrointestinal symptoms is generally of the dry flushing variant, which may be an important clinical clue to the differential diagnosis. A number of primary diseases of the gastrointestinal tract cause flushing, and conversely extra-intestinal conditions are associated with flushing and gastrointestinal symptoms. Gastrointestinal findings vary and include one or more of the following non-specific symptoms such as abdominal pain, nausea, vomiting, diarrhea or constipation. The purpose of this review is to provide a focused comprehensive discussion on the presentation, pathophysiology, diagnostic evaluation and management of those diseases that arise from the gastrointestinal tract or other site that may cause gastrointestinal symptoms secondarily accompanied by flushing. The paper is divided into two parts given the scope of conditions that cause flushing and affect the gastrointestinal tract. Part 1 covered is neuroendocrine tumors, (carcinoid, pheochromocytomas, vasoactive intestinal polypeptide, medullary carcinoma of the thyroid) polyneuropathy, organomegaly, endocrinopathy, monoclonal protein, skin changes (POEMS), and conditions involving mast cells and basophils. Part 2 covered is dumping syndrome, mesenteric traction syndrome, rosacea, hyperthyroidism and thyroid storm, anaphylaxis, panic disorders, paroxysmal extreme pain disorder, and food, alcohol and medications. © 2018 Marshfield Clinic.
Intelligent Local Avoided Collision (iLAC) MAC Protocol for Very High Speed Wireless Network
NASA Astrophysics Data System (ADS)
Hieu, Dinh Chi; Masuda, Akeo; Rabarijaona, Verotiana Hanitriniala; Shimamoto, Shigeru
Future wireless communication systems aim at very high data rates. As the medium access control (MAC) protocol plays the central role in determining the overall performance of the wireless system, designing a suitable MAC protocol is critical to fully exploit the benefit of high speed transmission that the physical layer (PHY) offers. In the latest 802.11n standard [2], the problem of long overhead has been addressed adequately but the issue of excessive colliding transmissions, especially in congested situation, remains untouched. The procedure of setting the backoff value is the heart of the 802.11 distributed coordination function (DCF) to avoid collision in which each station makes its own decision on how to avoid collision in the next transmission. However, collision avoidance is a problem that can not be solved by a single station. In this paper, we introduce a new MAC protocol called Intelligent Local Avoided Collision (iLAC) that redefines individual rationality in choosing the backoff counter value to avoid a colliding transmission. The distinguishing feature of iLAC is that it fundamentally changes this decision making process from collision avoidance to collaborative collision prevention. As a result, stations can avoid colliding transmissions with much greater precision. Analytical solution confirms the validity of this proposal and simulation results show that the proposed algorithm outperforms the conventional algorithms by a large margin.
46 CFR 194.20-11 - Flushing systems.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 7 2014-10-01 2014-10-01 false Flushing systems. 194.20-11 Section 194.20-11 Shipping... Flushing systems. (a) Provision shall be made for flushing away chemical spills. (b) If a drainage system is installed, it shall be separate from any other drainage system. ...
46 CFR 194.20-11 - Flushing systems.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 7 2013-10-01 2013-10-01 false Flushing systems. 194.20-11 Section 194.20-11 Shipping... Flushing systems. (a) Provision shall be made for flushing away chemical spills. (b) If a drainage system is installed, it shall be separate from any other drainage system. ...
46 CFR 194.20-11 - Flushing systems.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 7 2010-10-01 2010-10-01 false Flushing systems. 194.20-11 Section 194.20-11 Shipping... Flushing systems. (a) Provision shall be made for flushing away chemical spills. (b) If a drainage system is installed, it shall be separate from any other drainage system. ...
Gómez-Fernández, J; Gómez-Izquierdo, E; Tomás, C; Mocé, E; de Mercado, E
2013-04-01
The aim of the present study was to determine whether the levels of reactive oxygen species (ROS) substances production and the levels of lipid peroxidation of the sperm membrane were related to the quality that the ejaculates exhibited after cryopreservation in boars. Ejaculates from 42 healthy boars were used in this study and they were cryopreserved with the lactose-egg yolk extender (LEY). Several sperm quality parameters were assessed by flow cytometry in samples incubated for 30 and 150 min at 37 °C after thawing: the percentage of sperm with intact plasma membrane (SIPM), intracellular reactive oxygen substances production through mean of DCF fluorescence intensity of total sperm (mean-DCF) and the percentage of viable and non-viable sperm containing oxidized BODIPY (VSOB and NVSOB). In addition, the percentages of total motile (TMS) and progressively motile sperm (PMS) were assessed at the same incubation times with a computer-assisted sperm analysis system. The classification of the ejaculates into good or bad freezers was performed through hierarchical cluster analysis from SIPM and TMS at 150 min post-thawing. The ejaculates of those males classified as good freezers exhibited higher (p < 0.05) SPIM, TMS and PMS than the bad freezers, although both groups presented similar (p > 0.05) VSOB, NVSOB and mean-DCF. Therefore, these results show that lipid peroxidation and the amount of reactive oxygen substances in the sperm after cryopreservation are similar between boars classified as good or bad freezers. © 2012 Blackwell Verlag GmbH.
Su, Yiming; Jassby, David; Song, Shikun; Zhou, Xuefei; Zhao, Hongying; Filip, Jan; Petala, Eleni; Zhang, Yalei
2018-06-05
Sulfidation of nanoscale zerovalent iron (nZVI) has shown some fundamental improvements on reactivity and selectivity toward pollutants in dissolved-oxygen (DO)-stimulated Fenton-like reaction systems (DO/S-nZVI system). However, the pristine microstructure of sulfide-modified nanoscale zerovalent iron (S-nZVI) remains uncovered. In addition, the relationship between pollutant removal and the oxidation of the S-nZVI is largely unknown. The present study confirms that sulfidation not only imparts sulfide and sulfate groups onto the surface of the nanoparticle (both on the oxide shell and on flake-like structures) but also introduces sulfur into the Fe(0) core region. Sulfidation greatly inhibits the four-electron transfer pathway between Fe(0) and oxygen but facilitates the electron transfer from Fe(0) to surface-bound Fe(III) and consecutive single-electron transfer for the generation of H 2 O 2 and hydroxyl radical. In the DO/S-nZVI system, slight sulfidation (S/Fe molar ratio = 0.1) is able to nearly double the oxidative removal efficacy of diclofenac (DCF) (from 17.8 to 34.2%), whereas moderate degree of sulfidation (S/Fe molar ratio = 0.3) significantly enhances both oxidation and adsorption of DCF. Furthermore, on the basis of the oxidation model of S-nZVI, the DCF removal process can be divided into two steps, which are well modeled by parabolic and logarithmic law separately. This study bridges the knowledge gap between pollutant removal and the oxidation process of chemically modified iron-based nanomaterials.
Desorption of micropollutant from spent carbon filters used for water purifier.
Kwon, Da-Sol; Tak, So-Yeon; Lee, Jung-Eun; Kim, Moon-Kyung; Lee, Young Hwa; Han, Doo Won; Kang, Sanghyeon; Zoh, Kyung-Duk
2017-07-01
In this study, to examine the accumulated micropollutants in the spent carbon filter used in the water purifier, first, the method to desorb micropollutant from the activated carbon was developed and optimized. Then, using this optimized desorption conditions, we examined which micropollutants exist in spent carbon filters collected from houses in different regions in Korea where water purifiers were used. A total of 11 micropollutants (caffeine (CFF), acetaminophen (ACT), sulfamethazine (SMA), sulfamethoxazole (SMZ), metoprolol (MTP), carbamazepine (CBM), naproxen (NPX), bisphenol-A (BPA), ibuprofen (IBU), diclofenac (DCF), and triclocarban (TCB)) were analyzed using LC/MS-MS from the spent carbon filters. CFF, NPX, and DCF had the highest detection frequencies (>60%) in the carbon filters (n = 100), whereas SMA, SMZ, and MTP were only detected in the carbon filters, but not in the tap waters (n = 25), indicating that these micropollutants, which exist less than the detection limit in tap water, were accumulated in the carbon filters. The regional micropollutant detection patterns in the carbon filters showed higher levels of micropollutants, especially NPX, BPA, IBU, and DCF, in carbon filters collected in the Han River and Nakdong River basins where large cities exist. The levels of micropollutants in the carbon filter were generally lower in the regions where advanced oxidation processes (AOPs) were employed at nearby water treatment plants (WTPs), indicating that AOP process in WTP is quite effective in removing micropollutant. Our results suggest that desorption of micropollutant from the carbon filter used can be a tool to identify micropollutants present in tap water with trace amounts or below the detection limit.
All fiber nonlinear microscopy at 1550 nm using a double-clad fiber coupler
NASA Astrophysics Data System (ADS)
Perrillat-Bottonet, Thomas; Strupler, Mathias; Leduc, Mikael; Majeau, Lucas; Godbout, Nicolas; Boudoux, Caroline
2017-02-01
Nonlinear microscopy has already shown its impact in biological research, namely in the fields of neurobiology, immunology, cancer research and embryology. Typically, these microscopes operate under free space propagation, using a dichroic mirror to separate the nonlinear signals from the excitation laser. While powerful such implementations are difficult to translate from the laboratory to a clinical setting where the environment is less controlled. Therefore, we propose an alignment-free all-fiber nonlinear microscopy system at 1550 nm based on double-clad fibers (DCF). As sectioning is performed through nonlinear effects, nonlinear microscopy does not require a detection pinhole, and. the DCF inner cladding can be used for efficient collection of nonlinear signals. The built system allows for multiplexing second harmonic generation (SHG) and two-photon excitation fluorescence (2PEF), collected from the inner cladding; and reflectance confocal microscopy (RCM), detected from the core acting as the confocal pinhole. Finally, an asymmetric double-clad fiber coupler (DCFC) is used to address efficiently both DCF channels. This all-fiber system is more compact and less sensitive to alignment, but requires carefully managing the transmission of the femtosecond pulse in the fiber. This is addressed using dispersion compensation fiber, pulse compression and solitonic propagation. Additionally, with a source centered at 1550 nm, we benefit from reduced sample scattering thus increasing the depth of field in comparison with systems operating at 800 nm. Overall we believe that the developed system could be transferred in clinics to enable in-vivo and in-situ imaging of human patient.
Chen, Weirui; Li, Xukai; Tang, Yiming; Zhou, Jialu; Wu, Dan; Wu, Yin; Li, Laisheng
2018-03-15
A flexible catalyst, Fe-Cu-MCM-41, was employed to enhance diclofenac (DCF) mineralization and inhibit bromate formation in catalytic ozonation process. Greater TOC removal was achieved in Fe-Cu-MCM-41/O 3 process (78%) than those in Fe-MCM-41/O 3 (65%), Cu-MCM-41/O 3 (73%) and sole ozonation (42%). But it was interesting that both Cu-MCM-41/O 3 and Fe-MCM-41/O 3 achieved 93% bromate inhibition efficiency, only 71% inhibition efficiency was observed in Fe-Cu-MCM-41/O 3 . Influence of pH, TBA/NaHSO 3 and detection of by-products were conducted to explore the mechanism. By Pyridine adsorption-IR and XPS, a relationship was found among activity of catalysts, Lewis acid sites and electron transfer effect between Fe (II/III) and Cu (I/II). Fe-Cu-MCM-41 promoted ozone decomposition to generate OH, which accounted for enhanced DCF mineralization. The consumption of aqueous O 3 also suppressed the oxidative of Br - and HBrO/Br - . More HBrO/BrO - accumulated in catalytic ozonation process and less bromate generated. Bromate formation in Fe-Cu-MCM-41/O 3 process was sensitive with pH value, the acidic condition was not favor for bromate formation. Both DCF mineralization and bromate inhibition were influenced by surface reaction. Moreover, Fe-Cu-MCM-41 showed excellent catalytic performance in suppressing the accumulation of carboxylic acid, especially for oxalic acid. Nearly no oxalic acid was detected during Fe-Cu-MCM-41/O 3 process. Copyright © 2017 Elsevier B.V. All rights reserved.
Li, Xukai; Chen, Weirui; Tang, Yiming; Li, Laisheng
2018-05-12
Fe-MCM-48 catalyst with a three-dimensional cubic pore structure was directly synthesized via a hydrothermal method, and the mineralization efficiency of diclofenac (DCF) in the catalytic ozonation process (Fe-MCM-48/O 3 ) was assessed. X-ray diffraction (XRD), N 2 adsorption desorption, transmission electron microscopy (TEM) and X-ray photoelectron spectroscopy (XPS) characterizations revealed that Fe existed in the framework of MCM-48, and Fe-MCM-48 possessed a large surface area and a highly ordered cubic mesoporous structure, which could accelerate reactants and products diffusion. Regarding mineralization efficiency, the addition of Fe-MCM-48 significantly improved total organic carbon (TOC) removal, and approximately 49.9% TOC were removed through the Fe-MCM-48/O 3 process at 60 min, which was 2.0 times higher than that in single ozonation. Due to this catalyst's superior structure, Fe-MCM-48 showed the better catalytic activity compared with Fe-MCM-41 and Fe loaded MCM-48 (Fe/MCM-48, Fe existed on the surface of MCM-48). DCF removal in the Fe-MCM-48/O 3 process was primarily based on ozone direct oxidation. The improvement of mineralization efficiency was attributed to the function of generated hydroxyl radicals (•OH), which indicated that the presence of Fe-MCM-48 accelerated ozone decomposition. Moreover, the negatively charged surface of Fe-MCM-48 and the proper pH value of the DCF solution played an essential role in OH generation. Copyright © 2018 Elsevier Ltd. All rights reserved.
Reactivation and reuse of TiO2-SnS2 composite catalyst for solar-driven water treatment.
Kovacic, Marin; Kopcic, Nina; Kusic, Hrvoje; Stangar, Urska Lavrencic; Dionysiou, Dionysios D; Bozic, Ana Loncaric
2018-01-01
One of the most important features of photocatalytic materials intended to be used for water treatment is their long-term stability. The study is focused on the application of thermal and chemical treatments for the reactivation of TiO 2 -SnS 2 composite photocatalyst, prepared by hydrothermal synthesis and immobilized on the glass support using titania/silica binder. Such a catalytic system was applied in solar-driven treatment, solar/TiO 2 -SnS 2 /H 2 O 2 , for the purification of water contaminated with diclofenac (DCF). The effectiveness of studied reactivation methods for retaining TiO 2 -SnS 2 activity in consecutive cycles was evaluated on basis of DCF removal and conversion, and TOC removal and mineralization of organic content. Besides these water quality parameters, biodegradability changes in DCF aqueous solution treated by solar/TiO 2 -SnS 2 /H 2 O 2 process using simply reused (air-dried) and thermally and chemically reactivated composite photocatalyst through six consecutive cycles were monitored. It was established that both thermal and chemical reactivation retain TiO 2 -SnS 2 activity in the second cycle of its reuse. However, both treatments caused the alteration in the TiO 2 -SnS 2 morphology due to the partial transformation of visible-active SnS 2 into non-active SnO 2 . Such alteration, repeated through consecutive reactivation and reuse, was reflected through gradual activity loss of TiO 2 -SnS 2 composite in applied solar-driven water treatment.
A method for measuring the cleaning effect of flushing disinfectors.
Cederberg, A.; Osterberg, K.
1980-01-01
A method is presented with which the mechanical cleaning effect of flushing disinfectors can be estimated independently of the thermal disinfecting effect of the hot flushing water. This makes it possible to specify the demands to be placed on the disinfecting effect of flushing with water of 85 degrees C or more. Bacillus stearothermophilus spores suspended in faeces were used as indicators because of their non-sensitivity to the hot-water temperature. Their elimination by flushing could thus be attributed to the mechanical effect of the water and not to the disinfecting effect of the temperature. A simple bacteriological technique was used, and the elimination factor (EF) was calculated as the ratio of the number of micro-organisms in the contamination before and after flushing. By using flushing water below 50 degrees C for 130 s the EF on a bedpan was about 10(4)-10(6). The effect of flushing with water of the same temperature for only half that time was somewhat weaker and when the temperature was raised to 85 degrees C after half the flushing time the effect was somewhat stronger. It can be presumed that the conventional disinfecting phase with hot (85 degrees C) water for about 45 s in the commonly used flushing units could be substantially shortened and the costs of their use thereby reduced. PMID:6820026
Rohlffs, Fiona; Tsilimparis, Nikolaos; Saleptsis, Vasilis; Diener, Holger; Debus, E Sebastian; Kölbel, Tilo
2017-02-01
To investigate the amount of gas released from Zenith thoracic stent-grafts using standard saline flushing vs the carbon dioxide flushing technique. In an experimental bench setting, 20 thoracic stent-grafts were separated into 2 groups of 10 endografts. One group of grafts was flushed with 60 mL saline and the other group was flushed with carbon dioxide for 5 minutes followed by 60 mL saline. All grafts were deployed into a water-filled container with a curved plastic pipe; the deployment was recorded and released gas was measured using a calibrated setup. Gas was released from all grafts in both study groups during endograft deployment. The average amount of released gas per graft was significantly lower in the study group with carbon dioxide flushing (0.79 vs 0.51 mL, p=0.005). Thoracic endografts release significant amounts of air during deployment if flushed according to the instructions for use. Application of carbon dioxide for the flushing of thoracic stent-grafts prior to standard saline flush significantly reduces the amount of gas released during deployment. The additional use of carbon dioxide should be considered as a standard flush technique for aortic stent-grafts, especially in those implanted in proximal aortic segments, to reduce the risk of air embolism and stroke.
Guan, Zhuo; Tang, Xiang-Yu; Nishimura, Taku; Katou, Hidetaka; Liu, Hui-Yun; Qing, Jing
2018-02-01
Soil contamination by diesel has been often reported as a result of accidental spillage, leakage and inappropriate use. Surfactant-enhanced soil flushing is a common remediation technique for soils contaminated by hydrophobic organic chemicals. In this study, soil flushing with linear alkylbenzene sulfonates (LAS, an anionic surfactant) was conducted for intact columns (15cm in diameter and 12cm in length) of diesel-contaminated farmland purple soil aged for one year in the field. Dynamics of colloid concentration in column outflow during flushing, diesel removal rate and resulting soil macroporosity change by flushing were analyzed. Removal rate of n-alkanes (representing the diesel) varied with the depth of the topsoil in the range of 14%-96% while the n-alkanes present at low concentrations in the subsoil were completely removed by LAS-enhanced flushing. Much higher colloid concentrations and larger colloid sizes were observed during LAS flushing in column outflow compared to water flushing. The X-ray micro-computed tomography analysis of flushed and unflushed soil cores showed that the proportion of fine macropores (30-250μm in diameter) was reduced significantly by LAS flushing treatment. This phenomenon can be attributed to enhanced clogging of fine macropores by colloids which exhibited higher concentration due to better dispersion by LAS. It can be inferred from this study that the application of LAS-enhanced flushing technique in the purple soil region should be cautious regarding the possibility of rapid colloid-associated contaminant transport via preferential pathways in the subsurface and the clogging of water-conducting soil pores. Copyright © 2017. Published by Elsevier B.V.
Truitt, E B; Gaynor, C R; Mehl, D L
1987-01-01
Aspirin (ASA) was tested in a group of 8 Oriental and 3 Occidental subjects who were shown in a previous study to respond to small doses of ethanol (0.06-0.25 g/kg) with facial flushing. They were compared to a similar group of 11 non-flushing Occidental subjects following a larger ethanol dose (0.37 g/kg) to determine if similar effects could be produced in less sensitive individuals. Control tests of blood ethanol and acetaldehyde (AcH) levels (calculated from breath), facial and neck skin temperatures, body sway (Romberg test), blood pressure, heart rate and 10 Subjective High Assessment Scales (SHAS-Judd, 1977) were conducted before and at 15, 30, 60 and 90 minutes after drinking ethanol as vodka in orange juice. The tests were repeated one week later one hour after receiving 0.64 gm of ASA orally. ASA produced slight changes in the early absorption of ethanol and small decreases in AcH levels in the flushing and non-flushing groups. Facial flushing was markedly reduced in the flushing group, but was slightly increased in the non-flushing Occidentals. Body sway was reduced by ASA in both groups. An alcohol-induced increase in heart rate in the flushing group was reduced with no change in blood pressure. SHAS subjective parameters were widely variable, but indicated that ASA produced reduced sleepiness and earlier relaxation in the flushing group. It is concluded that ASA can block alcohol-induced facial flushing in sensitive subjects and also reduces body sway in the Romberg test and alters some subjective feelings of alcohol intoxication.
A hazard of the Intraflo continuous flush system.
Schwartz, A J; Stoner, B B; Jobes, D R
1977-01-01
Patency of pressure sensing systems can be provided by the Intraflow Continuous Flush System (Sorenson Research Company, Salt Lake City, UT 84115). This device allows continuous flow of flush solution through a regulatory valve while preventing transmission of the high pressure of the flush solution. The case presented describes the recognition of a false elevation of a monitored pressure secondary to the malfunction of the Intraflo regulatory valve. Elimination of the flush solution high pressure during monitoring prevents inappropriate data collection.
Management of Contaminants Stored in Low Permeability Zones - A State of the Science Review
2013-10-01
Tank 3: Permanganate ................................................................................................... 193...Treatment options explored include steady water flushing (control), enhance water flushing, flushing permanganate , a dechlorinating culture (KB1...Remediation Tank Experiments (OoM: Order of Magnitude. PV: Pore Volume) 2. Enhanced flushing (79 PVs after loading) 3. Permanganate (45 PVs
Oberwittler, H; Baccara-Dinet, M
2006-06-01
Nicotinic acid (NA) is highly effective and widely used in the management of dyslipidaemia. For many patients, the side effect of flushing of the face and upper body leads to discontinuation. Flushing with NA is mediated by prostaglandins, and as acetyl salicylic acid (ASA, 'aspirin') is a highly effective inhibitor of prostaglandin synthesis, there is a rationale for its use to prevent or reduce the severity of NA-related flushing. This literature survey identified four studies specifically exploring the utility of ASA in preventing NA-related flushing in healthy volunteers. Twenty-three NA studies, where ASA was mandatory or optional within the protocol, and four studies, where background ASA therapy was reported in most participants, were also identified. Although the incidence of flushing in studies using ASA was often high, discontinuation rates due to flushing were low (mean 7.7%). This figure compares favourably with discontinuation rates with NA commonly reported in the literature (up to approximately 40%). There is good supportive evidence for the use of ASA in reducing the severity of NA-related flushing.
Li, Dong; Sun, Delin; Hu, Siyang; Hu, Jing; Yuan, Xingzhong
2016-02-01
A conceptual design and experiments, electrochemistry-flushing (E-flushing), using electrochemistry to enhance flushing efficiency for the remediation of Cr(Ⅵ)-contaminated soil is presented. The rector contained three compartments vertically superposed. The upper was airtight cathode compartment containing an iron-cathode. The middle was soil layer. The bottom was anode compartment containing an iron-anode and connected to a container by circulation pumps. H2 and OH(-) ions were produced at cathode. H2 increased the gas pressure in cathode compartment and drove flushing solution into soil layer forming flushing process. OH(-) ions entered into soil layer by eletromigration and hydraulic flow to enhance the desorption of Cr(Ⅵ). High potential gradient was applied to accelerate the electromigration of desorbed Cr(Ⅵ) ions and produced joule heat to increase soil temperature to enhance Cr(Ⅵ) desorption. In anode compartment, Fe(2+) ions produced at iron-anode reduced the desorbed Cr(Ⅵ) into Cr(3+) ions, which reacted with OH(-) ions forming Cr(OH)3. Experimental results show that Cr(Ⅵ) removal efficiency of E-flushing experiments was more than double of flushing experiments and reached the maximum of removal efficiency determined by desorption kinetics. All electrochemistry processes were positively used in E-flushing technology. Copyright © 2015 Elsevier Ltd. All rights reserved.
Neurokinin B administration induces hot flushes in women.
Jayasena, Channa N; Comninos, Alexander N; Stefanopoulou, Evgenia; Buckley, Adam; Narayanaswamy, Shakunthala; Izzi-Engbeaya, Chioma; Abbara, Ali; Ratnasabapathy, Risheka; Mogford, Julianne; Ng, Noel; Sarang, Zubair; Ghatei, Mohammad A; Bloom, Stephen R; Hunter, Myra S; Dhillo, Waljit S
2015-02-16
Neurokinin B (NKB) is a hypothalamic neuropeptide binding preferentially to the neurokinin 3 receptor. Expression of the gene encoding NKB is elevated in postmenopausal women. Furthermore, rodent studies suggest that NKB signalling may mediate menopausal hot flushes. However, the effects of NKB administration on hot flushes have not been investigated in humans. To address this, we performed a randomised, double-blinded, placebo-controlled, 2-way cross-over study. Ten healthy women were admitted to a temperature and humidity-controlled research unit. Participants received 30 minute intravenous infusions of NKB and vehicle in random order. Symptoms, heart rate, blood pressure, sweating and skin temperature were compared between NKB and vehicle in a double-blinded manner. Eight of ten participants experienced flushing during NKB infusion with none experiencing flushing during vehicle infusion (P = 0.0007). Significant elevations in heart rate (P = 0.0106 vs. pre-symptoms), and skin temperature measured using skin probe (P = 0.0258 vs. pre-symptoms) and thermal imaging (P = 0.0491 vs. pre-symptoms) characteristic of menopausal flushing were observed during hot flush episodes. Our findings provide evidence that NKB administration can cause hot flushes in women. Further studies are required to determine if pharmacological blockade of NKB signalling could inhibit hot flushes during the menopause and during treatment for sex-steroid dependent cancers.
Spatio-temporal evolution of apparent resistivity during coal-seam hydraulic flushing
NASA Astrophysics Data System (ADS)
Li, Dexing; Wang, Enyuan; Song, Dazhao; Qiu, Liming; Kong, Xiangguo
2018-06-01
Hydraulic flushing in gas predrainage is widely used, but the hydraulic-flushing effect is evaluated in a traditional way, by determining the desorption volume, moisture content, gas drainage rate and other conventional indices. To verify the rationality and feasibility of the multielectrode resistivity method in the evaluation of coal-seam hydraulic flushing and to research the spatio-temporal evolution of apparent resistivity during hydraulic flushing, a field test was conducted in 17# coal seam at Nuodong Mine, Guizhou. During hydraulic flushing, four stages were defined according to the variation in coal rock resistivity with time, namely, the preparation stage, the sharply decreasing stage, the rapidly increasing stage and the steady stage. The apparent resistivity of the coal rock mass is affected mainly by its own degree of fragmentation and flushing volume. A more serious rupture and a greater flushing volume yield a smaller apparent resistivity during the sharply decreasing stage and a higher resistivity during the stable stage. After three months of gas predrainage, the residual gas content and the gas pressure at different points in the expected affected area decrease below the critical value. Changes in the residual gas content and gas pressure at these points are consistent with the apparent resistivity, which validates the rationality and feasibility of the multielectrode resistivity method in evaluating coal-seam hydraulic flushing.
Tuomikoski, P; Mikkola, T S; Tikkanen, M J; Ylikorkala, O
2010-10-01
Menopausal hot flushes may affect the responses of various vascular risk factors to hormone therapy (HT). We compared the responses of biochemical markers for cardiovascular diseases to HT in recently postmenopausal women with tolerable or intolerable hot flushes. Healthy, non-smoking freshly postmenopausal women (n = 150) with no previous HT use were studied. Seventy-two women reported intolerable hot flushes (> or =7 moderate/severe episodes/day) and 78 women tolerable hot flushes (< or =3 mild episodes/day). The participants were treated in randomized order with either transdermal estradiol gel (1 mg), oral estradiol valerate (2 mg) with or without medroxyprogesterone acetate (5 mg), or placebo for 6 months. Treatment-induced changes in lipids, lipoproteins, apolipoproteins, sex hormone binding globulin (SHBG) and high-sensitivity C-reactive protein were compared. The trial is registered in the US National Institutes of Health Clinical Research Registry (no. NCT00668603). Pretreatment hot flush status was not related to the responses of these markers to different forms of HT. However, when all active regimens were evaluated together as a post-hoc analysis, 7/10 markers showed a tendency toward greater beneficial changes in women with intolerable hot flushes. Furthermore, in women with intolerable hot flushes and with HT use, the increases in SHBG (Spearman's rho = - 0.570, p < 0.001) were related to the reductions in hot flushes during the use of HT. Hot flushes appear to be no significant determinant for the responses of vascular markers to HT use.
An intensive behavioral weight loss intervention and hot flushes in women.
Huang, Alison J; Subak, Leslee L; Wing, Rena; West, Delia Smith; Hernandez, Alexandra L; Macer, Judy; Grady, Deborah
2010-07-12
Higher body mass index is associated with worse hot flushes during menopause but the effect of weight loss on flushing is unclear. Self-administered questionnaires were used to assess bothersome hot flushes in a 6-month randomized controlled trial of an intensive behavioral weight loss program (intervention) vs a structured health education program (control) in 338 women who were overweight or obese and had urinary incontinence. Weight, body mass index, abdominal circumference, physical activity, calorie intake, blood pressure, and physical and mental functioning were assessed at baseline and at 6 months. Repeated-measures proportional odds models examined intervention effects on bothersome hot flushes and potential mediating factors. Approximately half of participants (n = 154) were at least slightly bothered by hot flushes at baseline. Among these women, the intervention was associated with greater improvement in bothersome flushes vs control (odds ratio [OR] for improvement by 1 Likert category, 2.25; 95% confidence interval [CI], 1.20-4.21). Reductions in weight (OR, 1.32; 95% CI, 1.08-1.61; per 5-kg decrease), body mass index (1.17; 1.05-1.30; per 1-point decrease), and abdominal circumference (1.32; 1.07-1.64; per 5-cm decrease) were each associated with improvement in flushing, but changes in physical activity, calorie intake, blood pressure, and physical and mental functioning were not related. The effect of the intervention on flushing was modestly diminished after adjustment for multiple potential mediators (OR, 1.92; 95% CI, 0.95-3.89). Among women who were overweight or obese and had bothersome hot flushes, an intensive behavioral weight loss intervention resulted in improvement in flushing relative to control. Trial Registration clinicaltrials.gov Identifier: NCT00091988.
Duration of Menopausal Hot Flushes and Associated Risk Factors
Freeman, Ellen W.; Sammel, Mary D.; Lin, Hui; Liu, Ziyue; Gracia, Clarisa R.
2011-01-01
OBJECTIVE To estimate the duration of moderate-to-severe menopausal hot flushes and identify potential risk factors for hot flush duration. METHODS The Penn Ovarian Aging Study cohort was followed for 13 years. Hot flushes were evaluated at 9-month to 12-month intervals through in-person interviews. The primary outcome was the duration of moderate to severe hot flushes, estimated by survival analysis (N=259). Potential risk factors included menopausal stage, age, race, reproductive hormone levels, body mass index (BMI) and current smoking. A secondary analysis included women who reported any hot flushes (N=349). RESULTS The median duration of moderate to severe hot flushes was 10.2 years and was strongly associated with menopausal stage at onset. Hot flushes that commenced near entry into the menopause transition had a median duration >greater than 11.57 years; onset in the early transition stage had a median duration of 7.35 years (95% CI 4.94, 8.89), P<0.001); and onset in the late transition to postmenopausal stages had a median duration of 3.84 years (95% CI: 1.77, 5.52), P<0.001. The most common ages at onset of moderate-to-severe hot flushes were 45–49 years (median duration 8.1 years; 95% CI 5.12, 9.28). African American women had a longer duration of hot flushes than white women in adjusted analysis. CONCLUSIONS The median duration of hot flushes considerably exceeded the time frame that is generally accepted in clinical practice. The identified risk factors, particularly menopausal stage, race, and BMI, are important to consider in individualizing treatment and evaluating the risk to benefit ratio of hormones and other therapies. PMID:21508748
21 CFR 870.1210 - Continuous flush catheter.
Code of Federal Regulations, 2014 CFR
2014-04-01
...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1210 Continuous flush catheter. (a) Identification. A continuous flush catheter is an attachment to a catheter-transducer system...
21 CFR 870.1210 - Continuous flush catheter.
Code of Federal Regulations, 2012 CFR
2012-04-01
...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1210 Continuous flush catheter. (a) Identification. A continuous flush catheter is an attachment to a catheter-transducer system...
21 CFR 870.1210 - Continuous flush catheter.
Code of Federal Regulations, 2013 CFR
2013-04-01
...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1210 Continuous flush catheter. (a) Identification. A continuous flush catheter is an attachment to a catheter-transducer system...
The role of natural ventilation in the exposure to radon in the Postojna Cave
NASA Astrophysics Data System (ADS)
Gregorič, A.; Smerajec, M.; Vaupotič, J.
2012-04-01
Postojna Cave is the biggest of 21 show caves in Slovenia and one of present day's most visited show caves in the world. Long and branched out cave system, large entrances at different levels, inflow of the Pivka river, and large variation of the outdoor air temperature and precipitation, make the Postojna Cave also a very complex climatic system in which each part shows different conditions. The cave is only naturally ventilated and it is therefore characterised by high radon concentration, which depends on the ventilation regime in different seasons, resulting in typical annual cycles of radon levels in the cave air. Postojna Cave is a typical horizontal cave, where the difference between outside and cave air temperature represents the main driving force for air circulation. In winter, when the cave temperature is higher than outside, cave air is released from the cave into the outdoor atmosphere due to the air draught caused by the 'chimney effect', thus allowing fresh and cold outdoor air to enter the cave through low lying openings. This effect is not operative in summer, when the outside temperature is higher than in the cave, and air draught is minimal or reversed. In addition, air circulation can be locally altered due to other processes, like changing level of Pivka river during the rainy season and local geomorphologic characteristics of cave passages. High radon concentration in the Postojna Cave is the reason for thorough studies of the methodology for dose estimates of the personnel working in the cave. Due to high relative humidity and low air circulation, the cave air is characterised by very low particle concentration, which play an important role in radon dosimetry. Therefore parallel monitoring of radioactive aerosols of radon decay products (RnDP) and general (non-radioactive) aerosols in the particle size range of 10-1100 nm was performed in the air of Postojna Cave at the lowest point of tourist path in summer, winter and both transitional periods (spring and autumn), focusing on the unattached fraction of RnDP (fun), a key parameter in radon dosimetry. Dose conversion factors (DCF) were calculated (using Porstendörfer approach) from measured fun for the four periods and compared with recommended DCF, based on the results of epidemiological studies. Results of calculated DCF are in the range from 8-18 mSV WLM-1, much higher that recommended values, and differ significantly for summer and winter period. The lowest value of DCF was calculated for winter period, when the enhanced inflow of cold outside air introduces outdoor aerosols into the cave and consequently lowers fun. On the other hand, calculated DCF during summer period was significantly higher, caused by high fun, which is the consequence of very low particle concentration in cave air during summer ventilation regime. Taking into account also significantly higher radon concentration during summer, when about 70 % of visits is recorded, it is evident, that personnel receives the highest annual dose during summer months.
Aerosol Generation by Modern Flush Toilets.
Johnson, David; Lynch, Robert; Marshall, Charles; Mead, Kenneth; Hirst, Deborah
A microbe-contaminated toilet will produce bioaerosols when flushed. We assessed toilet plume aerosol from high efficiency (HET), pressure-assisted high efficiency (PAT), and flushometer (FOM) toilets with similar bowl water and flush volumes. Total and droplet nuclei "bioaerosols" were assessed. Monodisperse 0.25-1.9- μ m fluorescent microspheres served as microbe surrogates in separate trials in a mockup 5 m 3 water closet (WC). Bowl water seeding was approximately 10 12 particles/mL. Droplet nuclei were sampled onto 0.2- μ m pore size mixed cellulose ester filters beginning 15 min after the flush using open-face cassettes mounted on the WC walls. Pre- and postflush bowl water concentrations were measured. Filter particle counts were analyzed via fluorescent microscopy. Bowl headspace droplet count size distributions were bimodal and similar for all toilet types and flush conditions, with 95% of droplets < 2 μ m diameter and > 99% < 5 μ m. Up to 145,000 droplets were produced per flush, with the high-energy flushometer producing over three times as many as the lower energy PAT and over 12 times as many as the lowest energy HET despite similar flush volumes. The mean numbers of fluorescent droplet nuclei particles aerosolized and remaining airborne also increased with flush energy. Fluorescent droplet nuclei per flush decreased with increasing particle size. These findings suggest two concurrent aerosolization mechanisms-splashing for large droplets and bubble bursting for the fine droplets that form droplet nuclei.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hanson, P.J.; Isebrands, J.G.; Dickson, R.E.
1988-03-01
Oak (Quercus) seedlings exhibit a pattern of shoot growth known to place demands on carbohydrate and nutrient reserves. This study was designed to determine ontogenetic patterns in CO{sub 2} exchanges properties of red oak leaves, and to determine if individual leaf CO{sub 2} exchange rates (CER) increase in response to the assimilate demand placed on a seedling during flushing. Northern red oak (Q. rubra L.) seedlings were grown in environments favorable for multiple flushes of shoot growth. Measurements of CER on single, attached, median leaves from each flush were made over a range of photosynthetic photon flux densities on plantsmore » at nine stages of seedling development through three flushes of growth. Carbon dioxide exchange rate of red oak leaves increased during leaf development up to and beyond full leaf expansion before decreasing an unusual pattern of photosynthesis during leaf ontogeny. Furthermore, first- and second-flush leaf CER initially decreased and then increased in conjunction with the third flush of shoot growth. These patterns indicate that red oak leaves have a capacity for CER adjustment in response to increase sink demand.« less
Etiologies and management of cutaneous flushing: Nonmalignant causes.
Sadeghian, Azeen; Rouhana, Hailey; Oswald-Stumpf, Brittany; Boh, Erin
2017-09-01
The flushing phenomenon may represent a physiologic or a pathologic reaction. Although flushing is usually benign, it is prudent that the physician remains aware of potentially life-threatening conditions associated with cutaneous flushing. A thorough investigation should be performed if the flushing is atypical or not clearly associated with a benign underlying process. The diagnosis often relies on a pertinent history, review of systems, physical examination, and various laboratory and imaging modalities, all of which are discussed in the 2 articles in this continuing medical education series. This article reviews flushing associated with fever, hyperthermia, emotions, menopause, medications, alcohol, food, hypersensitivity reactions, rosacea, hyperthyroidism, dumping syndrome, superior vena cava syndrome, and neurologic etiologies. Copyright © 2016 American Academy of Dermatology, Inc. Published by Elsevier Inc. All rights reserved.
Azuma, Takashi; Nakada, Norihide; Yamashita, Naoyuki; Tanaka, Hiroaki
2015-11-01
A year-round monitoring survey of sewage flowing into sewage treatment plants located in urban Japan was conducted by targeting seven representative pharmaceutical components-atenolol (ATL), ciprofloxacin (CFX), clarithromycin (CTM), diclofenac (DCF), diltiazem (DTZ), disopyramide (DSP), and sulpiride (SPR)-detected in the river environment. For each of these components, two types of predicted concentration were estimated on the basis of two types of data (the shipping volume and sales volume of each component). The measured concentration of each component obtained through the survey and the two types of estimated predicted concentration of each component were then compared. The correspondence ratio between the predicted concentration estimated from the shipping volume of the component and the measured concentration (predicted concentration/measured concentration) was, for ATL, 3.1; CFX, 1.4; CTM, 1.4; DCF, 0.2; DTZ, 0.9; DSP, 11.6; and SPR, 1.1. The correspondence ratio between the predicted concentration estimated from the sales volume of the component and the measured concentration was, for ATL, 0.5; CFX, 1.1; CTM, 0.8; DCF, 0.1; DTZ, 0.2; DSP, 0.7; and SPR, 0.8. Although a generally corresponding trend was seen regardless of whether the prediction was based on shipping volume or sales volume, the predicted concentrations estimated from the shipping volumes of all components expect DSP were found, to our knowledge for the first time in Japan, to correspond better than those based on sales volumes to the measured concentrations. These findings should help to improve the prediction accuracy of concentrations of pharmaceutical components in river waters. Copyright © 2015 Elsevier Ltd. All rights reserved.
Oxidative stress increases internal calcium stores and reduces a key mitochondrial enzyme.
Gibson, Gary E; Zhang, Hui; Xu, Hui; Park, Larry C H; Jeitner, Thomas M
2002-03-16
Fibroblasts from patients with genetic and non-genetic forms of Alzheimer's disease (AD) show many abnormalities including increased bombesin-releasable calcium stores (BRCS), diminished activities of the mitochondrial alpha-ketoglutarate dehydrogenase complex (KGDHC), and an altered ability to handle oxidative stress. The link between genetic mutations (and the unknown primary event in non-genetic forms) and these other cellular abnormalities is unknown. To determine whether oxidative stress could be a convergence point that produces the other AD-related changes, these experiments tested in fibroblasts the effects of H(2)O(2), in the presence or absence of select antioxidants, on BRCS and KGDHC. H(2)O(2) concentrations that elevated carboxy-dichlorofluorescein (c-H(2)DCF)-detectable ROS increased BRCS and decreased KGDHC activity. These changes are in the same direction as those in fibroblasts from AD patients. Acute treatments with the antioxidants Trolox, or DMSO decreased c-H(2)DCF-detectable ROS by about 90%, but exaggerated the H(2)O(2)-induced increases in BRCS by about 4-fold and did not alter the reduction in KGDHC. Chronic pretreatments with Trolox more than doubled the BRCS, tripled KGDHC activities, and reduced the effects of H(2)O(2). Pretreatment with DMSO or N-acetyl cysteine diminished the BRCS and either had no effect, or exaggerated the H(2)O(2)-induced changes in these variables. The results demonstrate that BRCS and KGDHC are more sensitive to H(2)O(2) derived species than c-H(2)DCF, and that oxidized derivatives of the antioxidants exaggerate the actions of H(2)O(2). The findings support the hypothesis that select abnormalities in oxidative processes are a critical part of a cascade that leads to the cellular abnormalities in cells from AD patients.
On the effect of serum on the transport of reactive oxygen species across phospholipid membranes.
Szili, Endre J; Hong, Sung-Ha; Short, Robert D
2015-06-24
The transport of plasma generated reactive oxygen species (ROS) across a simple phospholipid membrane mimic of a (real) cell was investigated. Experiments were performed in cell culture media (Dulbecco's modified Eagle's medium, DMEM), with and without 10% serum. A (broad spectrum) ROS reporter dye, 2,7-dichlorodihydrofluorescein (DCFH), was used to detect the generation of ROS by a helium (He) plasma jet in DMEM using free DCFH and with DCFH encapsulated inside phospholipid membrane vesicles dispersed in DMEM. The authors focus on the concentration and on the relative rates (arbitrary units) for oxidation of DCFH [or the appearance of the oxidized product 2,7-dichlorofluorescein (DCF)] both in solution and within vesicles. In the first 1 h following plasma exposure, the concentration of free DCF in DMEM was ~15× greater in the presence of serum (cf. to the serum-free DMEM control). The DCF in vesicles was ~2× greater in DMEM containing serum compared to the serum-free DMEM control. These data show that serum enhances plasma ROS generation in DMEM. As expected, the role of the phospholipid membrane was to reduce the rate of oxidation of the encapsulated DCFH (with and without serum). And the efficiency of ROS transport into vesicles was lower in DMEM containing serum (at 4% efficiency) when compared to serum-free DMEM (at 32% efficiency). After 1 h, the rate of DCFH oxidation was found to have significantly reduced. Based upon a synthesis of these data with results from the open literature, the authors speculate on how the components of biological fluid and cellular membranes might affect the kinetics of consumption of plasma generated ROS.
Cordero-García, A; Turnes Palomino, G; Hinojosa-Reyes, L; Guzmán-Mar, J L; Maya-Teviño, L; Hernández-Ramírez, A
2017-02-01
In this study, the photocatalytic removal of an emerging contaminant, diclofenac (DCF) sodium, was performed using the nitrogen-doped WO 3 /TiO 2 -coupled oxide catalyst (WO 3 /TiO 2 -N). The catalyst synthesis was accomplished by a sol-gel method using tetrabutyl orthotitanate (C 16 H 36 O 4 Ti), ammonium p-tungstate [(NH 4 ) 10 H 2 W 12 O 42 ·4H 2 O] and ammonium nitrate (NH 4 NO 3 ) as the nitrogen source. For comparison, TiO 2 and WO 3 /TiO 2 were also prepared under similar conditions. Analysis by X-ray diffraction (XRD), N 2 adsorption-desorption, scanning electron microscopy (SEM), transmission electron microscopy (TEM), diffuse reflectance UV-Vis spectroscopy (DRS) and X-ray photoelectron spectroscopy (XPS) were conducted to characterize the synthesized materials. The photocatalytic efficiency of the semiconductors was determined in a batch reactor irradiated with simulated solar light. Residual and mineralized DCF were quantified by high-performance liquid chromatography, total organic carbon analysis and ion exchange chromatography. The results indicated that the tungsten atoms were dispersed on the surface of TiO 2 as WO 3 . The partial substitution of oxygen by nitrogen atoms into the lattice of TiO 2 was an important factor to improve the photocatalytic efficiency of WO 3 /TiO 2 . Therefore, the best photocatalytic activity was obtained with the WO 3 /TiO 2 -N 0.18 catalyst, reaching 100% DCF transformation at 250 kJ m -2 and complete mineralization at 400 kJ m -2 of solar-accumulated energy.
The fate of selected pharmaceuticals in solar stills: Transfer, thermal degradation or photolysis?
Baalbaki, Abbas; Ayoub, George M; Al-Hindi, Mahmoud; Ghauch, Antoine
2017-01-01
The increase in demand for, and disposal of, pharmaceuticals, positively correlated with the growing human population, has led to the emergence of contaminants with high environmental and health impacts. Several developing countries that endure problems related to water sufficiency and/or quality resort to the use solar stills as an affordable water treatment method. This research is aimed at investigating the fate of five chemically distinct pharmaceuticals that might pervade solar stills; ibuprofen (IBU), diclofenac (DCF), carbamazepine (CBZ), ampicillin (AMP) and naproxen (NPX). The experiments were conducted under three conditions. The first condition studied the combined effect of temperature and light in simulated field-test-scale solar stills. The effect of temperature as a sole variable was investigated in the second while the third condition studied the effect of light only via concentrated solar power (CSP). Results show that distillates from solar stills did not contain the parent compounds for four out of the five pharmaceuticals. IBU was the only pharmaceutical that showed a transfer via vapor into the distillate with the highest recorded transfer percentage of 2.1% at 50°C when subjected to temperature alone and 0.6% under the combined effect of temperature and light. In the case of NPX and DCF, the parent compounds did not undergo transfer into the distillate phase; however their degradation by-products did. In addition, the results also showed that in the case of NPX, IBU and CBZ both high temperatures and sunlight combined were required to attain noticeable degradation. CSP accelerated the degradation of DCF, NPX and IBU with a three-minutes-degradation percentage of 44%, 13% and 2% respectively. Copyright © 2016 Elsevier B.V. All rights reserved.
Clewell, H J; Gearhart, J M; Gentry, P R; Covington, T R; VanLandingham, C B; Crump, K S; Shipp, A M
1999-08-01
An analysis of the uncertainty in guidelines for the ingestion of methylmercury (MeHg) due to human pharmacokinetic variability was conducted using a physiologically based pharmacokinetic (PBPK) model that describes MeHg kinetics in the pregnant human and fetus. Two alternative derivations of an ingestion guideline for MeHg were considered: the U.S. Environmental Protection Agency reference dose (RfD) of 0.1 microgram/kg/day derived from studies of an Iraqi grain poisoning episode, and the Agency for Toxic Substances and Disease Registry chronic oral minimal risk level (MRL) of 0.5 microgram/kg/day based on studies of a fish-eating population in the Seychelles Islands. Calculation of an ingestion guideline for MeHg from either of these epidemiological studies requires calculation of a dose conversion factor (DCF) relating a hair mercury concentration to a chronic MeHg ingestion rate. To evaluate the uncertainty in this DCF across the population of U.S. women of child-bearing age, Monte Carlo analyses were performed in which distributions for each of the parameters in the PBPK model were randomly sampled 1000 times. The 1st and 5th percentiles of the resulting distribution of DCFs were a factor of 1.8 and 1.5 below the median, respectively. This estimate of variability is consistent with, but somewhat less than, previous analyses performed with empirical, one-compartment pharmacokinetic models. The use of a consistent factor in both guidelines of 1.5 for pharmacokinetic variability in the DCF, and keeping all other aspects of the derivations unchanged, would result in an RfD of 0.2 microgram/kg/day and an MRL of 0.3 microgram/kg/day.
Lima, Lisandra; Baêta, Bruno E L; Lima, Diego R S; Afonso, Robson J C F; de Aquino, Sérgio F; Libânio, Marcelo
2016-01-01
The aim of this study was to evaluate the performance of two forms of basic granular activated carbon (GAC), mineral (pH = 10.5) and vegetal (pH = 9), for the removal of three pharmaceuticals, as sulphamethoxazole (SMX), diclofenac (DCF) and 17β-estradiol (E2), from two different matrices: fortified distilled (2.4-3.0 mg L(-1) and pH from 5.5 to 6.5) and natural (∼1.0 mg L(-1) and pH from 7.1 to 7.2) water in a bench scale. The Rapid Small-Scale Column Test used to assess the ability of mineral and vegetal GAC on removal of such pharmaceuticals led to removal capacities varying from 14.9 to 23.5 mg g(-1) for E2, from 23.7 to 24.2 mg g(-1) for DCF and from 20.5 to 20.6 mg g(-1) for SMX. Removal efficiencies of 71%, 88% and 74% for DCF, SMX and E2, respectively, were obtained at breakthrough point when using mineral GAC, whereas for the vegetal GAC the figures were 76%, 77% and 65%, respectively. The carbon usage rate at the breakthrough point varied from 11.9 to 14.5 L g(-1) for mineral GAC and from 8.8 to 14.8 L g(-1) for vegetal GAC. Mineral CAG also exhibited the best performance when treating fortified natural water, since nearly complete removal was observed for all contaminants in the column operated for 22 h at a carbon usage rate of 2.9 L g(-1).
Ultrafast electron and energy transfer in dye-sensitized iron oxide and oxyhydroxide nanoparticles.
Gilbert, Benjamin; Katz, Jordan E; Huse, Nils; Zhang, Xiaoyi; Frandsen, Cathrine; Falcone, Roger W; Waychunas, Glenn A
2013-10-28
An emerging area in chemical science is the study of solid-phase redox reactions using ultrafast time-resolved spectroscopy. We have used molecules of the photoactive dye 2',7'-dichlorofluorescein (DCF) anchored to the surface of iron(III) oxide nanoparticles to create iron(II) surface atoms via photo-initiated interfacial electron transfer. This approach enables time-resolved study of the fate and mobility of electrons within the solid phase. However, complete analysis of the ultrafast processes following dye photoexcitation of the sensitized iron(III) oxide nanoparticles has not been reported. We addressed this topic by performing femtosecond transient absorption (TA) measurements of aqueous suspensions of uncoated and DCF-sensitized iron oxide and oxyhydroxide nanoparticles, and an aqueous iron(III)-dye complex. Following light absorption, excited state relaxation times of the dye of 115-310 fs were found for all samples. Comparison between TA dynamics on uncoated and dye-sensitized hematite nanoparticles revealed the dye de-excitation pathway to consist of a competition between electron and energy transfer to the nanoparticles. We analyzed the TA data for hematite nanoparticles using a four-state model of the dye-sensitized system, finding electron and energy transfer to occur on the same ultrafast timescale. The interfacial electron transfer rates for iron oxides are very close to those previously reported for DCF-sensitized titanium dioxide (for which dye-oxide energy transfer is energetically forbidden) even though the acceptor states are different. Comparison of the alignment of the excited states of the dye and the unoccupied states of these oxides showed that the dye injects into acceptor states of different symmetry (Ti t2gvs. Fe eg).
Daniele, Gaëlle; Fieu, Maëva; Joachim, Sandrine; Bado-Nilles, Anne; Baudoin, Patrick; Turies, Cyril; Porcher, Jean-Marc; Andres, Sandrine; Vulliet, Emmanuelle
2016-06-01
Pharmaceuticals are emerging organic contaminants ubiquitously present in the environment due to incessant input into the aquatic compartment mainly resulting from incomplete removal in wastewater treatment plants. One of the major preoccupations concerning pharmaceuticals released into surface waters is their potential for bioaccumulation in biota, possibly leading to deleterious effects on ecosystems especially as they could affect a broad variety of organisms living in or depending on the aquatic environment. Thus, the development of accurate and sensitive methods is necessary to detect these compounds in aquatic ecosystems. Considering this need, this study deals with the analytical development of a methodology to quantify traces of diclofenac together with some of its biotic and abiotic transformation products in whole-body tissue of three-spined stickleback. A simple and reliable extraction method based on a modified QuEChERS extraction is implemented on 200 mg of fish. The detection and quantification of the ten target compounds are performed using liquid chromatography-tandem mass spectrometry. The whole process was successfully validated regarding linearity, recovery, repeatability, and reproducibility. The method limits of detection and quantification do not exceed 1 ng/g. To reproduce environmental conditions, we measured the concentration of DCF and its transformation products in three-spined sticklebacks after a 6-month exposure in mesocosms at several levels of DCF ranging from 0.05 to 4.1 μg/L. The phase I metabolite 4'-hydroxydiclofenac was detected in fish samples exposed at the highest DCF concentration. Graphical abstract Analysis of diclofenac and some of its transformation products in the three-spined stickleback, Gasterosteus aculeatus, by QuEChERS extraction followed by LC-MS/MS.
C. S., Lim; M. S., Shaharuddin; W. Y., Sam
2013-01-01
Introduction: A cross sectional study was conducted to estimate risk of exposure to lead via tap water ingestion pathway for the population of Seri Kembangan (SK). Methodology: By using purposive sampling method, 100 respondents who fulfilled the inclusive criteria were selected from different housing areas of SK based on geographical population distribution. Residents with filtration systems installed were excluded from the study. Questionnaires were administered to determine water consumption-related information and demographics. Two water samples (first-flushed and fully-flushed samples) were collected from kitchen tap of each household using HDPE bottles. A total of 200 water samples were collected and lead concentrations were determined using a Graphite Furnace Atomic Absorption Spectrophotometer (GFAAS). Results: Mean lead concentration in first-flushed samples was 3.041± SD 6.967µg/L and 1.064± SD 1.103µg/L for fully-flushed samples. Of the first-flushed samples, four (4) had exceeded the National Drinking Water Quality Standard (NDWQS) lead limit value of 10µg/L while none of the fully-flushed samples had lead concentration exceeded the limit. There was a significant difference between first-flushed samples and fully-flushed samples and flushing had elicited a significant change in lead concentration in the water (Z = -5.880, p<0.05). It was also found that lead concentration in both first-flushed and fully flushed samples was not significantly different across nine (9) areas of Seri Kembangan (p>0.05). Serdang Jaya was found to have the highest lead concentration in first-flushed water (mean= 10.44± SD 17.83µg/L) while Taman Universiti Indah had the highest lead concentration in fully-flushed water (mean=1.45± SD 1.83µg/L). Exposure assessment found that the mean chronic daily intake (CDI) was 0.028± SD 0.034µgday-1kg-1. None of the hazard quotient (HQ) value was found to be greater than 1. Conclusion: The overall quality of water supply in SK was satisfactory because most of the parameters tested in this study were within the range of permissible limit and only a few samples had exceeded the standard values for lead and pH. Non-carcinogenic risk attributed to ingestion of lead in SK tap water was found to be negligible. PMID:23445691
Lim, C S; Shaharuddin, M S; Sam, W Y
2012-11-21
A cross sectional study was conducted to estimate risk of exposure to lead via tap water ingestion pathway for the population of Seri Kembangan (SK). By using purposive sampling method, 100 respondents who fulfilled the inclusive criteria were selected from different housing areas of SK based on geographical population distribution. Residents with filtration systems installed were excluded from the study. Questionnaires were administered to determine water consumption-related information and demographics. Two water samples (first-flushed and fully-flushed samples) were collected from kitchen tap of each household using HDPE bottles. A total of 200 water samples were collected and lead concentrations were determined using a Graphite Furnace Atomic Absorption Spectrophotometer (GFAAS). Mean lead concentration in first-flushed samples was 3.041± SD 6.967µg/L and 1.064± SD 1.103µg/L for fully-flushed samples. Of the first-flushed samples, four (4) had exceeded the National Drinking Water Quality Standard (NDWQS) lead limit value of 10µg/L while none of the fully-flushed samples had lead concentration exceeded the limit. There was a significant difference between first-flushed samples and fully-flushed samples and flushing had elicited a significant change in lead concentration in the water (Z = -5.880, p<0.05). It was also found that lead concentration in both first-flushed and fully flushed samples was not significantly different across nine (9) areas of Seri Kembangan (p>0.05). Serdang Jaya was found to have the highest lead concentration in first-flushed water (mean= 10.44± SD 17.83µg/L) while Taman Universiti Indah had the highest lead concentration in fully-flushed water (mean=1.45± SD 1.83µg/L). Exposure assessment found that the mean chronic daily intake (CDI) was 0.028± SD 0.034µgday-1kg-1. None of the hazard quotient (HQ) value was found to be greater than 1. The overall quality of water supply in SK was satisfactory because most of the parameters tested in this study were within the range of permissible limit and only a few samples had exceeded the standard values for lead and pH. Non-carcinogenic risk attributed to ingestion of lead in SK tap water was found to be negligible.
Apical dominance and apical control in multiple flushing of temperate woody species.
M. Cline; C. Harrington
2007-01-01
In young plants of many woody species, the first flush of growth in the spring may be followed by one or more flushes of the terminal shoot if growing conditions are favorable. The occurrence of these additional flushes may significantly affect crown form and structure. Apical dominance (AD) and apical control (AC) are thought to be important control mechanisms in this...
Ding, Lanyan; Yuen, Lok-Wa; Shell, Duane F.
2018-01-01
This study explored bystanders’ willingness to help a friend who flushes when drinking to reduce his/her drinking. Alcohol-related facial flushing is an indicator of an inherited variant enzyme, aldehyde dehydrogenase (ALDH), that impairs alcohol metabolism and increases drinkers’ lifetime risk of certain aerodigestive cancers. Individuals who flush should reduce their alcohol exposure, but they may continue to drink if social pressures and rules of etiquette make not drinking socially risky. The analysis used data from 2912 undergraduate students from 13 universities in southwestern, central and northeastern China from a survey asking how they respond to someone’s flushing in various scenarios. Latent class analysis grouped students by similar responses to flushing. A multinomial logistic regression explored how class membership was associated with knowledge, drinking status, and reactions to one’s own flushing. Five classes were derived from the latent class analysis, ranging from always intervene to mostly hesitate to help; in between were classes of students who were willing to help in some scenarios and hesitant in other scenarios. Only 11.6% students knew the connection between facial flushing and impaired alcohol metabolism, and knowledgeable students were somewhat more likely to assist when they saw someone flushing. In the absence of knowledge, other factors—such as drinking status, the gender of the bystander, the gender of the person who flushed, and degree of friendship with the person who flushed—determined how willing a person was to help someone reduce or stop drinking. Class membership was predicted by knowledge, gender, drinking status, and reactions to one’s own flushing. Of these 4 factors, knowledge and reactions to one’s own flushing could be influenced through alcohol education programs. It will take some time for alcohol education to catch up to and change social and cultural patterns of drinking. Meanwhile, motivational strategies should be developed to increase the willingness of bystanders to assist friends and to create a social expectation that flushers should stop or reduce their drinking. PMID:29693597
Gschwendtner, Silvia; Alatossava, Tapani; Kublik, Susanne; Fuka, Mirna Mrkonjić; Schloter, Michael; Munsch-Alatossava, Patricia
2016-01-01
The quality and safety of raw milk still remains a worldwide challenge. Culture-dependent methods indicated that the continuous N2 gas-flushing of raw milk reduced the bacterial growth during cold storage by up to four orders of magnitude, compared to cold storage alone. This study investigated the influence of N2 gas-flushing on bacterial diversity in bovine raw-milk samples, that were either cold stored at 6°C or additionally flushed with pure N2 for up to one week. Next-generation sequencing (NGS) of the V1-V2 hypervariable regions of 16S rRNA genes, derived from amplified cDNA, which was obtained from RNA directly isolated from raw-milk samples, was performed. The reads, which were clustered into 2448 operational taxonomic units (OTUs), were phylogenetically classified. Our data revealed a drastic reduction in the diversity of OTUs in raw milk during cold storage at 6°C at 97% similarity level; but, the N2-flushing treatment alleviated this reduction and substantially limited the loss of bacterial diversity during the same cold-storage period. Compared to cold-stored milk, the initial raw-milk samples contained less Proteobacteria (mainly Pseudomonadaceae, Moraxellaceae and Enterobacteriaceae) but more Firmicutes (mainly Ruminococcaceaea, Lachnospiraceae and Oscillospiraceaea) and Bacteroidetes (mainly Bacteroidales). Significant differences between cold-stored and additionally N2-flushed milk were mainly related to higher levels of Pseudomononadaceae (including the genera Pseudomonas and Acinetobacter) in cold-stored milk samples; furthermore, rare taxa were better preserved by the N2 gas flushing compared to the cold storage alone. No major changes in bacterial composition with time were found regarding the distribution of the major 9 OTUs, that dominated the Pseudomonas genus in N2-flushed or non-flushed milk samples, other than an intriguing predominance of bacteria related to P. veronii. Overall, this study established that neither bacteria causing milk spoilage nor any well-known human pathogen or anaerobe benefited from the N2 gas flushing even though the N2-flushed and non-flushed cold-stored milk differed in bacterial counts by up to 104-fold.
Kublik, Susanne; Fuka, Mirna Mrkonjić; Schloter, Michael; Munsch-Alatossava, Patricia
2016-01-01
The quality and safety of raw milk still remains a worldwide challenge. Culture-dependent methods indicated that the continuous N2 gas-flushing of raw milk reduced the bacterial growth during cold storage by up to four orders of magnitude, compared to cold storage alone. This study investigated the influence of N2 gas-flushing on bacterial diversity in bovine raw-milk samples, that were either cold stored at 6°C or additionally flushed with pure N2 for up to one week. Next-generation sequencing (NGS) of the V1-V2 hypervariable regions of 16S rRNA genes, derived from amplified cDNA, which was obtained from RNA directly isolated from raw-milk samples, was performed. The reads, which were clustered into 2448 operational taxonomic units (OTUs), were phylogenetically classified. Our data revealed a drastic reduction in the diversity of OTUs in raw milk during cold storage at 6°C at 97% similarity level; but, the N2-flushing treatment alleviated this reduction and substantially limited the loss of bacterial diversity during the same cold-storage period. Compared to cold-stored milk, the initial raw-milk samples contained less Proteobacteria (mainly Pseudomonadaceae, Moraxellaceae and Enterobacteriaceae) but more Firmicutes (mainly Ruminococcaceaea, Lachnospiraceae and Oscillospiraceaea) and Bacteroidetes (mainly Bacteroidales). Significant differences between cold-stored and additionally N2-flushed milk were mainly related to higher levels of Pseudomononadaceae (including the genera Pseudomonas and Acinetobacter) in cold-stored milk samples; furthermore, rare taxa were better preserved by the N2 gas flushing compared to the cold storage alone. No major changes in bacterial composition with time were found regarding the distribution of the major 9 OTUs, that dominated the Pseudomonas genus in N2-flushed or non-flushed milk samples, other than an intriguing predominance of bacteria related to P. veronii. Overall, this study established that neither bacteria causing milk spoilage nor any well-known human pathogen or anaerobe benefited from the N2 gas flushing even though the N2-flushed and non-flushed cold-stored milk differed in bacterial counts by up to 104-fold. PMID:26730711
Using continuous in-situ measurements to adaptively trigger urban storm water samples
NASA Astrophysics Data System (ADS)
Wong, B. P.; Kerkez, B.
2015-12-01
Until cost-effective in-situ sensors are available for biological parameters, nutrients and metals, automated samplers will continue to be the primary source of reliable water quality measurements. Given limited samples bottles, however, autosamplers often obscure insights on nutrient sources and biogeochemical processes which would otherwise be captured using a continuous sampling approach. To that end, we evaluate the efficacy a novel method to measure first-flush nutrient dynamics in flashy, urban watersheds. Our approach reduces the number of samples required to capture water quality dynamics by leveraging an internet-connected sensor node, which is equipped with a suite of continuous in-situ sensors and an automated sampler. To capture both the initial baseflow as well as storm concentrations, a cloud-hosted adaptive algorithm analyzes the high-resolution sensor data along with local weather forecasts to optimize a sampling schedule. The method was tested in a highly developed urban catchment in Ann Arbor, Michigan and collected samples of nitrate, phosphorus, and suspended solids throughout several storm events. Results indicate that the watershed does not exhibit first flush dynamics, a behavior that would have been obscured when using a non-adaptive sampling approach.
Endoscope system with plasma flushing and coaxial round jet nozzle for off-pump cardiac surgery.
Horiuchi, Tetsuya; Masamune, Ken; Iwase, Yuki; Ymashita, Hiromasa; Tsukihara, Hiroyuki; Motomura, Noboru; Ohta, Yuji; Dohi, Takeyoshi
2011-07-01
To develop a new endoscope for performing simple surgical tasks inside the blood-filled cardiac atrium/chamber, that is, "off-pump" cardiac surgeries. We developed the endoscope system with plasma flushing and coaxial round jet nozzle. The "plasma flushing" system was invented to observe the interior of the blood-filled heart by displacing blood cells in front of the endoscope tip. However, some areas could not be observed with simple flushing of the liquid because the flushed liquid mixed with blood. Further, a large amount of liquid had to be flushed, which posed a risk of cardiac damage caused by excess volume. Therefore, to safely capture high-resolution images of the interior of the heart, an endoscope with a coaxial round jet nozzle through which plasma is flushed has been developed. And to reduce the volume of flushed liquid, the synchronization system of heartbeat and the endoscope system with plasma flushing has been developed. We conducted an in vivo experiment to determine whether we could observe intracardiac tissues in swine without the use of a heart-lung machine. As a result, we successfully observed intracardiac tissues without using a heart-lung machine. By using a coaxial nozzle, we could even observe the tricuspid valve. Moreover, we were able to save up to 30% of the flushed liquid by replacing the original system with a synchronization system. And we evaluated the performance of the endoscope with the coaxial round jet nozzle by conducting fluid analysis and an in vitro experiment. We successfully observed intracardiac tissues without using a heart-lung machine. By using a coaxial nozzle, we could even observe the tricuspid valve. And by replacing an original system to a synchronization system, we were able to save up to 30% of the flushed liquid. As a follow-up study, we plan to create a surgical flexible device for valve disease that can grasp, staple, and repair cardiac valves by endoscopic visualization.
Simpson, Catherine R.; Alabi, Olufemi J.; Nelson, Shad D.; Telagamsetty, Srilakshmi; Jifon, John L.
2016-01-01
Studies were conducted to relate the influence of the physical characteristics, leaf nutrient content and phloem sap amino acid concentration of citrus flush shoots on the densities of various Diaphorina citri life stages. Adult D. citri preferentially selected young shoots for feeding and numbers of D. citri immatures were positively correlated with flush shoot softness. Young flush shoots had higher concentrations of macro and micro nutrients relative to mature ones and this was associated with higher densities of all D. citri life stages. All D. citri life stages were positively correlated with higher nitrogen-carbon (N:C), nitrogen:sulfur (N:S) and nitrogen:calcium (N:Ca) ratios in leaf tissue, while densities of adults were negatively related to calcium, manganese and boron levels. Concentrations of total and essential amino acids were highest in phloem sap of young expanding flush shoots in both grapefruit and lemon, but dramatically declined as flush shoots matured. The sulfur-containing amino acids cystine, methionine and taurine occurred only in younger flush shoots. In contrast, cystathionine was only present in phloem sap of mature shoots. These results clearly indicate that young citrus flush shoots are a nutritionally richer diet relative to mature shoots, thus explaining their preference by D. citri for feeding and reproduction. Conversely, tissue hardness and the lower nutritional quality of mature flush shoots may limit oviposition and immature development. The data suggest that both physical characteristics and nutritional composition of flush shoots and their phloem sap are important factors regulating host colonization and behavior of D. citri, and this interaction can impact the dynamics and spread of HLB in citrus groves. PMID:28030637
Achieving Fair Throughput among TCP Flows in Multi-Hop Wireless Mesh Networks
NASA Astrophysics Data System (ADS)
Hou, Ting-Chao; Hsu, Chih-Wei
Previous research shows that the IEEE 802.11 DCF channel contention mechanism is not capable of providing throughput fairness among nodes in different locations of the wireless mesh network. The node nearest the gateway will always strive for the chance to transmit data, causing fewer transmission opportunities for the nodes farther from the gateway, resulting in starvation. Prior studies modify the DCF mechanism to address the fairness problem. This paper focuses on the fairness study when TCP flows are carried over wireless mesh networks. By not modifying lower layer protocols, the current work identifies TCP parameters that impact throughput fairness and proposes adjusting those parameters to reduce frame collisions and improve throughput fairness. With the aid of mathematical formulation and ns2 simulations, this study finds that frame transmission from each node can be effectively controlled by properly controlling the delayed ACK timer and using a suitable advertised window. The proposed method reduces frame collisions and greatly improves TCP throughput fairness.
Lahti, Marja; Oikari, Aimo
2011-08-01
Although biotransformation is generally considered to be the main process by which to remove pharmaceuticals, both in sewage treatment plants and in aquatic environments, quantitative information on specific compounds is scarce. In this study, the transformations of diclofenac (DCF), naproxen (NPX), and bisoprolol (BSP) were studied under aerobic and anaerobic conditions using inocula taken from activated and digested sludge processes, respectively. Whereas concentration decays were monitored by LC-tandem mass spectrometry, oxygen consumption and methane production were used for the evaluation of the performance of overall conditions. DCF was recalcitrant against both aerobic and anaerobic biotransformation. More than one third of the BSP disappeared under aerobic conditions, whereas only 14% was anaerobically biotransformed in 161 days. Under aerobic conditions, complete removal of NPX was evident within 14 days, but anaerobic transformation was also efficient. Formation of 6-O-desmethylnaproxen, a previously reported aerobic metabolite, was also detected under anaerobic conditions and persisted for 161 days.
Pulmonary preservation studies: effects on endothelial function and pulmonary adenine nucleotides.
Paik, Hyo Chae; Hoffmann, Steven C; Egan, Thomas M
2003-02-27
Lung transplantation is an effective therapy plagued by a high incidence of early graft dysfunction, in part because of reperfusion injury. The optimal preservation solution for lung transplantation is unknown. We performed experiments using an isolated perfused rat lung model to test the effect of lung preservation with three solutions commonly used in clinical practice. Lungs were retrieved from Sprague-Dawley rats and flushed with one of three solutions: modified Euro-Collins (MEC), University of Wisconsin (UW), or low potassium dextran and glucose (LPDG), then stored cold for varying periods before reperfusion with Earle's balanced salt solution using the isolated perfused rat lung model. Outcome measures were capillary filtration coefficient (Kfc), wet-to-dry weight ratio, and lung tissue levels of adenine nucleotides and cyclic AMP. All lungs functioned well after 4 hr of storage. By 6 hr, UW-flushed lungs had a lower Kfc than LPDG-flushed lungs. After 8 hr of storage, only UW-flushed lungs had a measurable Kfc. Adenine nucleotide levels were higher in UW-flushed lungs after prolonged storage. Cyclic AMP levels correlated with Kfc in all groups. Early changes in endothelial permeability seemed to be better attenuated in lungs flushed with UW compared with LPDG or MEC; this was associated with higher amounts of adenine nucleotides. MEC-flushed lungs failed earlier than LPDG-flushed or UW-flushed lungs. The content of the solution may be more important for lung preservation than whether the ionic composition is intracellular or extracellular.
Aerosol Generation by Modern Flush Toilets
Johnson, David; Lynch, Robert; Marshall, Charles; Mead, Kenneth; Hirst, Deborah
2015-01-01
A microbe-contaminated toilet will produce bioaerosols when flushed. We assessed toilet plume aerosol from high efficiency (HET), pressure-assisted high efficiency (PAT), and flushometer (FOM) toilets with similar bowl water and flush volumes. Total and droplet nuclei “bioaerosols” were assessed. Monodisperse 0.25–1.9-μm fluorescent microspheres served as microbe surrogates in separate trials in a mockup 5 m3 water closet (WC). Bowl water seeding was approximately 1012 particles/mL. Droplet nuclei were sampled onto 0.2-μm pore size mixed cellulose ester filters beginning 15 min after the flush using open-face cassettes mounted on the WC walls. Pre- and postflush bowl water concentrations were measured. Filter particle counts were analyzed via fluorescent microscopy. Bowl headspace droplet count size distributions were bimodal and similar for all toilet types and flush conditions, with 95% of droplets <2 μm diameter and >99% <5 μm. Up to 145,000 droplets were produced per flush, with the high-energy flushometer producing over three times as many as the lower energy PAT and over 12 times as many as the lowest energy HET despite similar flush volumes. The mean numbers of fluorescent droplet nuclei particles aerosolized and remaining airborne also increased with flush energy. Fluorescent droplet nuclei per flush decreased with increasing particle size. These findings suggest two concurrent aerosolization mechanisms—splashing for large droplets and bubble bursting for the fine droplets that form droplet nuclei. PMID:26635429
Hot flushes and reproductive hormone levels during the menopausal transition.
Dhanoya, Tanveer; Sievert, Lynnette Leidy; Muttukrishna, Shanthi; Begum, Khurshida; Sharmeen, Taniya; Kasim, Adetayo; Chowdhury, Osul; Bentley, Gillian R
2016-07-01
Evidence suggests that hot flushes are associated with fluctuating levels of oestradiol (E2) during menopause, as well as changes in the levels of follicle-stimulating hormone (FSH) and inhibin B. The relationship between hot flushes and anti-Müllerian hormone (AMH) is unknown. To examine specific hormone levels and ethnic differences in relation to hot flushes. Data were drawn from 108 women aged 40-59 years. There were three groups of participants: European women in London, UK; Bangladeshi women in Sylhet, Bangladesh; and Bangladeshi women who had migrated to London as adults. Symptom information was collected via questionnaires. Serum blood samples were collected to detect inhibin B, AMH, FSH, and E2. AMH and FSH were significantly associated with the experience of hot flushes in the past 2 weeks. Inhibin B and E2 were not associated with hot flushes. Body mass index (BMI), ethnicity, and education level were associated with both the occurrence and the frequency hot flushes. Menopausal status was also associated with the frequency of hot flushes. Relationships between AMH, FSH and symptoms are indicative of women's progress through the menopausal transition. The influence of BMI and education suggest that lifestyle changes may contribute to the management of symptoms. This merits further research. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
30 CFR 56.7807 - Flushing the combustion chamber.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Rotary Jet Piercing Rotary Jet Piercing § 56.7807 Flushing the combustion chamber. The combustion chamber of a jet drill stem which has been sitting unoperated in a drill hole shall be flushed with a...
30 CFR 56.7807 - Flushing the combustion chamber.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Rotary Jet Piercing Rotary Jet Piercing § 56.7807 Flushing the combustion chamber. The combustion chamber of a jet drill stem which has been sitting unoperated in a drill hole shall be flushed with a...
Elhosary, Eman Abdelfatah Mohamed; Ewidea, Mahmoud Mohamed; Ahmed, Hamada Ahmed Hamada; El Khatib, Ayman
2018-02-01
[Purpose] To compare the effect of aerobic exercises versus laser acupuncture in treatment of postmenopausal hot flushes. [Subjects and Methods] This study was designed as single blind randomized controlled trial. A total of 48 postmenopausal women complained of hot flushes. Their ages ranged between 45 to 55 years and were randomly assigned into 2 equal groups: group (A), which received an aerobic exercises, and group (B), which received laser acupuncture. Both groups recieved 3 sessions per week for two months. The level of follicular stimulating hormone, lutelizing hormone, and hot flushes dairy card were assessed the severity of hot flahes before and after treatment program. [Results] There were Significant reduction in FSH, LH, and menopausal daily hot flush scale in group A compared with group B at the post treatment. [Conclusion] Eight week program of an aerobic exercises yields improvement in FSH, LH, and decrease in severity of hot flushes assessed by hot flush dairy card than laser acupuncture in the treatment of postmenopausal hot flashes.
Determining binder flushing causes in New York state.
DOT National Transportation Integrated Search
2014-12-01
In 2007, a number of asphalt pavements in New York State flushed. An extensive forensic and laboratory : investigation was conducted to determine why particular New York State asphalt pavements constructed in 2007 had : undergone atypical flush...
46 CFR 116.1110 - Drainage of flush deck vessels.
Code of Federal Regulations, 2013 CFR
2013-10-01
... ARRANGEMENT Drainage and Watertight Integrity of Weather Decks § 116.1110 Drainage of flush deck vessels. (a) Except as provided in paragraph (b) of this section, the weather deck on a flush deck vessel must be...
46 CFR 116.1110 - Drainage of flush deck vessels.
Code of Federal Regulations, 2012 CFR
2012-10-01
... ARRANGEMENT Drainage and Watertight Integrity of Weather Decks § 116.1110 Drainage of flush deck vessels. (a) Except as provided in paragraph (b) of this section, the weather deck on a flush deck vessel must be...
46 CFR 178.410 - Drainage of flush deck vessels.
Code of Federal Regulations, 2011 CFR
2011-10-01
... TONS) INTACT STABILITY AND SEAWORTHINESS Drainage of Weather Decks § 178.410 Drainage of flush deck vessels. (a) Except as provided in paragraph (b) of this section, the weather deck on a flush deck vessel...
46 CFR 178.410 - Drainage of flush deck vessels.
Code of Federal Regulations, 2012 CFR
2012-10-01
... TONS) INTACT STABILITY AND SEAWORTHINESS Drainage of Weather Decks § 178.410 Drainage of flush deck vessels. (a) Except as provided in paragraph (b) of this section, the weather deck on a flush deck vessel...
46 CFR 116.1110 - Drainage of flush deck vessels.
Code of Federal Regulations, 2014 CFR
2014-10-01
... ARRANGEMENT Drainage and Watertight Integrity of Weather Decks § 116.1110 Drainage of flush deck vessels. (a) Except as provided in paragraph (b) of this section, the weather deck on a flush deck vessel must be...
46 CFR 178.410 - Drainage of flush deck vessels.
Code of Federal Regulations, 2013 CFR
2013-10-01
... TONS) INTACT STABILITY AND SEAWORTHINESS Drainage of Weather Decks § 178.410 Drainage of flush deck vessels. (a) Except as provided in paragraph (b) of this section, the weather deck on a flush deck vessel...
46 CFR 178.410 - Drainage of flush deck vessels.
Code of Federal Regulations, 2014 CFR
2014-10-01
... TONS) INTACT STABILITY AND SEAWORTHINESS Drainage of Weather Decks § 178.410 Drainage of flush deck vessels. (a) Except as provided in paragraph (b) of this section, the weather deck on a flush deck vessel...
46 CFR 116.1110 - Drainage of flush deck vessels.
Code of Federal Regulations, 2010 CFR
2010-10-01
... ARRANGEMENT Drainage and Watertight Integrity of Weather Decks § 116.1110 Drainage of flush deck vessels. (a) Except as provided in paragraph (b) of this section, the weather deck on a flush deck vessel must be...
46 CFR 178.410 - Drainage of flush deck vessels.
Code of Federal Regulations, 2010 CFR
2010-10-01
... TONS) INTACT STABILITY AND SEAWORTHINESS Drainage of Weather Decks § 178.410 Drainage of flush deck vessels. (a) Except as provided in paragraph (b) of this section, the weather deck on a flush deck vessel...
Drug residues recovered in feed after various feedlot mixer truck cleanout procedures.
Van Donkersgoed, Joyce; Sit, Dan; Gibbons, Nicole; Ramogida, Caterina; Hendrick, Steve
2010-01-01
A study was conducted to determine the effectiveness of two methods of equipment cleanout, sequencing or flushing, for reducing drug carryover in feedlot mixer trucks. Feed samples were collected from total mixed rations before and after various feed mixer equipment cleanout procedures. Medicated rations contained either 11 ppm of tylosin or 166 or 331 ppm of chlortetracycline. There were no differences between sequencing and flushing or between flushing with dry barley and flushing with barley silage in the median proportion of drug recovered in the next ration. A larger drug reduction was achieved using flush material at a volume of 10 versus 5% of the mixer capacity and mixing the flush material for 3 versus 4 min. Regardless of the drug or prescription concentrations in the total mixed rations or the equipment cleanout procedure used, concentrations of chlortetracycline and tylosin recovered were very low.
Resistance training for hot flushes in postmenopausal women: Randomized controlled trial protocol.
Berin, Emilia; Hammar, Mats L; Lindblom, Hanna; Lindh-Åstrand, Lotta; Spetz Holm, Anna-Clara E
2016-03-01
Hot flushes and night sweats affect 75% of all women after menopause and is a common reason for decreased quality of life in mid-aged women. Hormone therapy is effective in ameliorating symptoms but cannot be used by all women due to contraindications and side effects. Engagement in regular exercise is associated with fewer hot flushes in observational studies, but aerobic exercise has not proven effective in randomized controlled trials. It remains to be determined whether resistance training is effective in reducing hot flushes and improves quality of life in symptomatic postmenopausal women. The aim of this study is to investigate the effect of standardized resistance training on hot flushes and other health parameters in postmenopausal women. This is an open, parallel-group, randomized controlled intervention study conducted in Linköping, Sweden. Sixty symptomatic and sedentary postmenopausal women with a mean of at least four moderate to severe hot flushes per day or 28 per week will be randomized to an exercise intervention or unchanged physical activity (control group). The intervention consists of 15 weeks of standardized resistance training performed three times a week under supervision of a physiotherapist. The primary outcome is hot flush frequency assessed by self-reported hot flush diaries, and the difference in change from baseline to week 15 will be compared between the intervention group and the control group. The intention is that this trial will contribute to the evidence base regarding effective treatment for hot flushes. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Chlormadinone acetate is effective for hot flush during androgen deprivation therapy
Koike, Hidekazu; Morikawa, Yasuyuki; Matsui, Hiroshi; Shibata, Yasuhiro; Ito, Kazuto; Suzuki, Kazuhiro
2013-01-01
Purpose: To investigate the clinical efficacy of low-dose chlormadinone acetate (CMA) in prostate cancer patients who suffer from hot flushes that is a major side effect of androgen deprivation therapy. Methods: Our study included 32 prostate cancer patients who had severe hot flush after undergoing hormone therapy for more than 3 months. The average age of the patients was 72.5 years. In the beginning, patients received CMA at 100 mg orally per day. We defined the hot flush as disappeared, improved, or not improved. In patients with disappeared or improved symptoms, we decreased CMA dose to 50 mg per day, and after we reevaluated the effect, we decreased CMA dose to 25 mg per day. When hot flush appeared again at 25 mg per day, we returned the dose of CMA to 50 mg per day. In cases with no change for more than two months, we canceled the treatment of CMA. Results: Hot flush disappeared in 17 patients, improved in 10 patients, and did not improve in 5 patients (reduction in 84% of hot flush patients). The median time to hot flush reduction was 1.16 months. The effect of CMA was maintained at 25 mg per day in 19 patients and at 50 mg per day in 8 patients. No patients had prostate-specific antigen failure in the treatment of CMA. Conclusions: When hot flush appears during treatment with luteinizing hormone-releasing hormone agonist for prostate cancer, it seems that CMA can improve it immediately in most patients. PMID:24223412
46 CFR 171.140 - Drainage of a flush deck vessel.
Code of Federal Regulations, 2014 CFR
2014-10-01
... PERTAINING TO VESSELS CARRYING PASSENGERS Drainage of Weather Decks § 171.140 Drainage of a flush deck vessel. (a) Except as provided in paragraph (b) of this section, the weather deck on a flush deck vessel must...
46 CFR 171.140 - Drainage of a flush deck vessel.
Code of Federal Regulations, 2010 CFR
2010-10-01
... PERTAINING TO VESSELS CARRYING PASSENGERS Drainage of Weather Decks § 171.140 Drainage of a flush deck vessel. (a) Except as provided in paragraph (b) of this section, the weather deck on a flush deck vessel must...
46 CFR 171.140 - Drainage of a flush deck vessel.
Code of Federal Regulations, 2013 CFR
2013-10-01
... PERTAINING TO VESSELS CARRYING PASSENGERS Drainage of Weather Decks § 171.140 Drainage of a flush deck vessel. (a) Except as provided in paragraph (b) of this section, the weather deck on a flush deck vessel must...
46 CFR 171.140 - Drainage of a flush deck vessel.
Code of Federal Regulations, 2012 CFR
2012-10-01
... PERTAINING TO VESSELS CARRYING PASSENGERS Drainage of Weather Decks § 171.140 Drainage of a flush deck vessel. (a) Except as provided in paragraph (b) of this section, the weather deck on a flush deck vessel must...
46 CFR 171.140 - Drainage of a flush deck vessel.
Code of Federal Regulations, 2011 CFR
2011-10-01
... PERTAINING TO VESSELS CARRYING PASSENGERS Drainage of Weather Decks § 171.140 Drainage of a flush deck vessel. (a) Except as provided in paragraph (b) of this section, the weather deck on a flush deck vessel must...
Suchomel, Miranda; Diab-Elschahawi, Magda; Kundi, Michael; Assadian, Ojan
2013-08-30
Non-touch fittings have been reported to be susceptible for Pseudomonas aeruginosa accumulation. A number of factors may contribute to this, including the frequency of usage, duration of water stagnation, or presence of plastic materials. Programmable non-touch fittings are appearing which allow regular automated post-flushing with cold water to prevent water stagnation. However, the ideal duration of post-flushing is unknown as well as the effect of pre-rinsing with cold water before use. Eight non-touch fittings with brass valve blocks were mounted on a mobile test sink and connected to the same central water pipe source, differing only in presence or absence of water connection pipes, length of connection pipe, frequency of usage, and time intervals for pre- and post-usage water flush. The total bacteria colony-forming unit (cfu) counts were obtained by the spread plate technique. Low frequency of water use in combination with a long stagnating water column resulted in high bacterial cfu counts. Post-usage flushing for 2 seconds did not differ from no flushing. Flushing for 10 seconds with cold water after use or 30 seconds flush before use were both the most effective measures to prevent non-touch fittings from biofilm formation over a period of 20 weeks. Further improvements in water fitting technology could possibly solve the problem of bacterial water contamination in health care settings.
Whelton, Andrew J; McMillan, LaKia; Connell, Matt; Kelley, Keven M; Gill, Jeff P; White, Kevin D; Gupta, Rahul; Dey, Rajarshi; Novy, Caroline
2015-01-20
During January 2014, an industrial solvent contaminated West Virginia’s Elk River and 15% of the state population’s tap water. A rapid in-home survey and water testing was conducted 2 weeks following the spill to understand resident perceptions, tap water chemical levels, and premise plumbing flushing effectiveness. Water odors were detected in all 10 homes sampled before and after premise plumbing flushing. Survey and medical data indicated flushing caused adverse health impacts. Bench-scale experiments and physiochemical property predictions showed flushing promoted chemical volatilization, and contaminants did not appreciably sorb into cross-linked polyethylene (PEX) pipe. Flushing reduced tap water 4-methylcyclohexanemethanol (4-MCHM) concentrations within some but not all homes. 4-MCHM was detected at unflushed (<10 to 420 μg/L) and flushed plumbing systems (<10 to 96 μg/L) and sometimes concentrations differed among faucets within each home. All waters contained less 4-MCHM than the 1000 μg/L Centers for Disease Control drinking water limit, but one home exceeded the 120 μg/L drinking water limit established by independent toxicologists. Nearly all households refused to resume water use activities after flushing because of water safety concerns. Science based flushing protocols should be developed to expedite recovery, minimize health impacts, and reduce concentrations in homes when future events occur.
Vithanage, M; Engesgaard, P; Jensen, K H; Illangasekare, T H; Obeysekera, J
2012-08-01
This intermediate scale laboratory experimental study was designed to improve the conceptual understanding of aquifer flushing time associated with diffuse saltwater contamination of coastal aquifers due to a tsunami-like event. The motivation comes from field observations made after the tsunami in December, 2004 in South Asia. The focus is on the role and effects of heterogeneity on flushing effectiveness. A scheme that combines experimentation in a 4.8m long laboratory tank and numerical modeling was used. To demonstrate the effects of geologic heterogeneity, plume migration and flushing times were analyzed in both homogeneous and layered media and under different boundary conditions (ambient flow, saltwater infiltration rate, freshwater recharge). Saltwater and freshwater infiltrations imitate the results of the groundwater salinization from the tsunami and freshening from the monsoon rainfall. The saltwater plume behavior was monitored both through visual observations (digital photography) of the dyed salt water and using measurements taken from several electrical conductivity sensors installed through the tank walls. The variable-density, three dimensional code HST3D was used to simulate the tank experiments and understand the fate and movement of the saltwater plume under field conditions. The results from the tank experiments and modeling demonstrated that macro-scale heterogeneity significantly influenced the migration patterns and flushing times of diffuse saltwater contamination. Ambient flow had a direct influence on total flush-out time, and heterogeneity impacted flush-out times for the top part of the tank and total flush-out times. The presence of a continuous low-permeability layer caused a 40% increase in complete flush-out time due to the slower flow of salt water in the low-permeability layer. When a relatively small opening was introduced in the low-permeability layer, salt water migrated quickly into a higher-permeable layer below causing a reduction in flush-out time. Freshwater recharge caused an early dilution of salt water in the top part of the tank in the case of a layered media, but also pushed the saltwater plume into the low-permeability layer which led to increased total flush-out times. Copyright © 2012 Elsevier B.V. All rights reserved.
ENGINEERING BULLETIN: IN SITU SOIL FLUSHING
In situ soil flushing is the extraction of contaminants from the soil with water or other suitable aqueous solutions. Soil flushing is accomplished by passing the extraction fluid through in-place soils using an injection or infiltration process. Extraction fluids must be recover...
Pinkerton, JoAnn V; Bushmakin, Andrew G; Bobula, Joel; Lavenberg, Joanne; Komm, Barry S; Abraham, Lucy
2017-12-01
To evaluate the impact of baseline hot flush frequency and severity on time to symptom improvement during treatment with conjugated estrogens/bazedoxifene (CE/BZA). Data were pooled through week 12 from two randomized placebo-controlled trials (SMART-1 and SMART-2) of nonhysterectomized postmenopausal women with hot flushes treated with CE 0.45 mg/BZA 20 mg or CE 0.625 mg/BZA 20 mg. Time to transient and stable improvement (≥ 50% reduction in hot flush frequency/severity) was estimated using nonparametric models. Transient improvement in hot flush frequency occurred earlier in women treated with CE 0.45 mg/BZA 20 mg with less frequent versus more frequent baseline hot flushes per day: median time to transient improvement was 2, 7, and 11 days for women with < 3, 3 to < 8, and ≥ 8 hot flushes per day at baseline, respectively (P = 0.0009). Transient improvement in severity occurred earlier for women with less severe versus more severe baseline hot flushes: median time to transient improvement was 2, 6, and 16 days for women with mild, moderate, and severe hot flushes at baseline, respectively (P < 0.0001). Stable improvement typically occurred 2 to 3 days after the transient event and was less influenced by baseline status. A similar pattern was observed with CE 0.625 mg/BZA 20 mg treatment, though improvement occurred a few days earlier than with CE 0.45 mg/BZA 20 mg. Women with more frequent/severe hot flushes take longer to achieve transient improvements with CE/BZA and should be encouraged to continue treatment, as it may take longer than a few weeks to achieve significant improvement.
Tidal flushing time of marine fish culture zones in Hong Kong
NASA Astrophysics Data System (ADS)
Mao, Jing-Qiao; Wong, Ken T. M.; Lee, Joseph H. W.; Choi, K. W.
2011-12-01
Accurate determination of flushing time is crucial for maintaining sustainable production in fish culture zones (FCZs), as it represents the physical self-purification capability via tidal exchange with clean water in the outer sea. However, owing to the temporal and spatial complexity of the coastal flushing process, existing methods for determining flushing time may not be generally applicable. In this paper, a systematic method for determining the flushing time in FCZs is presented, in which bathymetry, runoff, tidal range and stratification are properly accounted for. We determine the flushing time via numerical tracer experiments, using robust 3D hydrodynamic and mass transport models. For FCZs located in sheltered and land-locked tidal inlets, the system boundary can be naturally defined at the connection with the open sea. For FCZs located in open waters, hydrodynamic tracking is first used to assess the extent of tidal excursion and thus delimit the initial boundary between clean water and polluted water. This general method is applied to all designated marine FCZs in Hong Kong for both the dry and wet seasons, including 20 sheltered FCZs (in semi-enclosed waters of Tolo Harbour, Mirs Bay, and Port Shelter) and 6 FCZs in open waters. Our results show that flushing time is the longest in inner Port Shelter (about 40 days in dry season), and the shortest for the FCZs in open waters (less than one week in dry season). In addition, the flushing time in dry season is commonly longer than that in wet season: 20%˜40% for most well-sheltered FCZs; 2.6˜4 times for the others. Our results indicate a positive correlation between the flushing time and distance to open boundary, supporting the view that the flushing time of a FCZ is closely related to its location. This study provides a solid basis for mariculture management such as the determination of carrying capacity of FCZs.
Assessment of hot flushes and vaginal dryness among obese women undergoing bariatric surgery.
Goughnour, S L; Thurston, R C; Althouse, A D; Freese, K E; Edwards, R P; Hamad, G G; McCloskey, C; Ramanathan, R; Bovbjerg, D H; Linkov, F
2016-01-01
Menopausal symptoms are associated with a negative impact on the quality of life, leading women to seek medical treatment. Obesity has been linked to higher levels of menopausal symptoms such as hot flushes. This assessment will explore whether the prevalence and bother of hot flushes and vaginal dryness change from pre- to post-bariatric surgery among obese midlife women. This study is a longitudinal analysis of data from 69 women (ages 35-72 years) undergoing bariatric surgery with reported reproductive histories and menopausal symptoms at preoperative and 6-month postoperative visits. Prevalence of and degree of bother of hot flushes and vaginal dryness at pre- and post-surgery were compared using McNemar's test and Wilcoxon signed-rank test. The reported degree of bother of symptoms associated with hot flushes decreased from pre- to post-surgery (p < 0.01). There was no significant change in the prevalence of hot flushes or vaginal dryness in the overall study sample. The degree of bother of symptoms associated with hot flushes among midlife women may decrease after bariatric surgery. These results highlight important secondary gains, including less bothersome menopausal symptoms, for women who choose bariatric surgery for weight loss.
Citrus flush shoot ontogeny modulates biotic potential of Diaphorina citri.
Cifuentes-Arenas, Juan Camilo; de Goes, António; de Miranda, Marcelo Pedreira; Beattie, George Andrew Charles; Lopes, Silvio Aparecido
2018-01-01
The biology and behaviour of the psyllid Diaphorina citri Kuwayama (Hemiptera: Sternorrhyncha: Liviidae), the major insect vector of bacteria associated with huanglongbing, have been extensively studied with respect to host preferences, thermal requirements, and responses to visual and chemical volatile stimuli. However, development of the psyllid in relation to the ontogeny of immature citrus flush growth has not been clearly defined or illustrated. Such information is important for determining the timing and frequency of measures used to minimize populations of the psyllid in orchards and spread of HLB. Our objective was to study how flush ontogeny influences the biotic potential of the psyllid. We divided citrus flush growth into six stages within four developmental phases: emergence (V1), development (V2 and V3), maturation (V4 and V5), and dormancy (V6). Diaphorina citri oviposition and nymph development were assessed on all flush stages in a temperature controlled room, and in a screen-house in which ambient temperatures varied. Our results show that biotic potential of Diaphorina citri is not a matter of the size or the age of the flushes (days after budbreak), but the developmental stage within its ontogeny. Females laid eggs on flush V1 to V5 only, with the time needed to commence oviposition increasing with the increasing in flush age. Stages V1, V2 and V3 were most suitable for oviposition, nymph survival and development, and adult emergence, which showed evidence of protandry. Flush shoots at emerging and developmental phases should be the focus of any chemical or biological control strategy to reduce the biotic potential of D. citri, to protect citrus tree from Liberibacter infection and to minimize HLB dissemination.
Citrus flush shoot ontogeny modulates biotic potential of Diaphorina citri
de Goes, António; de Miranda, Marcelo Pedreira
2018-01-01
The biology and behaviour of the psyllid Diaphorina citri Kuwayama (Hemiptera: Sternorrhyncha: Liviidae), the major insect vector of bacteria associated with huanglongbing, have been extensively studied with respect to host preferences, thermal requirements, and responses to visual and chemical volatile stimuli. However, development of the psyllid in relation to the ontogeny of immature citrus flush growth has not been clearly defined or illustrated. Such information is important for determining the timing and frequency of measures used to minimize populations of the psyllid in orchards and spread of HLB. Our objective was to study how flush ontogeny influences the biotic potential of the psyllid. We divided citrus flush growth into six stages within four developmental phases: emergence (V1), development (V2 and V3), maturation (V4 and V5), and dormancy (V6). Diaphorina citri oviposition and nymph development were assessed on all flush stages in a temperature controlled room, and in a screen-house in which ambient temperatures varied. Our results show that biotic potential of Diaphorina citri is not a matter of the size or the age of the flushes (days after budbreak), but the developmental stage within its ontogeny. Females laid eggs on flush V1 to V5 only, with the time needed to commence oviposition increasing with the increasing in flush age. Stages V1, V2 and V3 were most suitable for oviposition, nymph survival and development, and adult emergence, which showed evidence of protandry. Flush shoots at emerging and developmental phases should be the focus of any chemical or biological control strategy to reduce the biotic potential of D. citri, to protect citrus tree from Liberibacter infection and to minimize HLB dissemination. PMID:29304052
A comparison of basal and eye-flush tears for the analysis of cat tear proteins.
Petznick, Andrea; Evans, Margaret D M; Madigan, Michele C; Markoulli, Maria; Garrett, Qian; Sweeney, Deborah F
2011-02-01
To identify a rapid and effective tear collection method providing sufficient tear volume and total protein content (TPC) for analysis of individual proteins in cats. Domestic adult short-haired cats (12-37 months; 2.7-6.6 kg) were used in the study. Basal tears without stimulation and eye-flush tears after instillation of saline (10 μl) were collected using microcapillary tubes from animal eyes either unwounded control or wounded with 9-mm central epithelial debridement giving four groups with n = 3. Tear comparisons were based on total time and rate for tear collection, TPC using micro bicinchoninic acid (BCA), tear immunoglobulin A (IgA), total matrix-metalloproteinase (MMP)-9 concentration using sandwich enzyme-linked immunosorbent assay (ELISA) and MMP-9 activity. Eye-flush tears were collected significantly faster than basal tears in wounded eyes with higher rates for tear collection in unwounded control and wounded eyes. TPC was significantly lower in eye-flush tears compared to basal tears. The relative proportion of tear IgA normalized to TPC (% IgA of TPC) was not significantly different between basal and eye-flush tears. In unwounded control eyes, MMP-9 was slightly higher in eye-flush than in basal tears; activity of MMP-9 in both tear types was similar. In wounded eyes, eye-flush tears showed highest MMP-9 levels and activity on Day 1, which subsequently decreased to Day 7. MMP-9 activity in basal tears from wounded eyes did not display changes in expression. Eye-flush tears can be collected rapidly providing sufficient tear volume and TPC. This study also indicates that eye-flush tears may be more suitable than basal tears for the analysis of MMPs following corneal wounding. © 2011 The Authors. Acta Ophthalmologica © 2011 Acta Ophthalmologica Scandinavica Foundation.
Microbiological Hazards of Household Toilets: Droplet Production and the Fate of Residual Organisms
Gerba, Charles P.; Wallis, Craig; Melnick, Joseph L.
1975-01-01
Large numbers of bacteria and viruses when seeded into household toilets were shown to remain in the bowl after flushing, and even continual flushing could not remove a persistent fraction. This was found to be due to the adsorption of the organisms to the porcelain surfaces of the bowl, with gradual elution occurring after each flush. Droplets produced by flushing toilets were found to harbor both bacteria and viruses which had been seeded. The detection of bacteria and viruses falling out onto surfaces in bathrooms after flushing indicated that they remain airborne long enough to settle on surface throughout the bathroom. Thus, there is a possibility that a person may acquire an infection from an aerosol produced by a toilet. PMID:169732
The flushing time of an estuary is generally defined as the turnover time of fresh water in the estuary, that is, the time required to replace the fresh water contained in the estuary with freshwater inflow. Thus, the flushing time of an estuary is the ratio of the volume of fres...
21 CFR 870.1210 - Continuous flush catheter.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Continuous flush catheter. 870.1210 Section 870.1210 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1210 Continuous flush...
21 CFR 870.1210 - Continuous flush catheter.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Continuous flush catheter. 870.1210 Section 870.1210 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1210 Continuous flush...
40 CFR 141.804 - Aircraft water system operations and maintenance plan.
Code of Federal Regulations, 2013 CFR
2013-07-01
... must include the following requirements for procedures for disinfection and flushing of aircraft water system. (i) The air carrier must conduct disinfection and flushing of the aircraft water system in... water procedures; (ii) Sample collection procedures; (iii) Disinfection and flushing procedures; (iv...
The pharmacological and hormonal therapy of hot flushes in breast cancer survivors.
Wiśniewska, Iwona; Jochymek, Bożena; Lenart-Lipińska, Monika; Chabowski, Mariusz
2016-03-01
The side effects of oncological treatment, which appear during or after therapy, are sometimes very annoying for patients and are not adequately treated by physicians. Among the symptoms experienced by breast cancer patients are hot flushes, which result from a natural or cancer therapy-induced menopause. The intensity of hot flushes in breast cancer patients may be more severe than those experienced by women undergoing a natural menopause. Taking into account the incidence of breast cancer and long-lasting hormone-suppression therapies, the problem of hot flushes will affect many women. Hormonal replacement therapy, the most effective therapeutic means for alleviating hot flushes, is usually contraindicated for breast cancer patients. For intense and severe hot flushes, pharmacological treatment using agents from a group of selective serotonin reuptake inhibitors and serotonin and norepinephrine reuptake inhibitors such as venlafaxine or citalopram may be introduced. Other agents from different pharmacological groups, such as clonidine, gabapentin, or pregabalin, have also proved to be effective in treating hot flushes. The efficacy of phytoestrogens has not been proven in randomized clinical trials. The importance of the placebo effect in decreasing vasomotor symptoms has also been reported in many research papers. Educating breast cancer patients in lifestyle changes which decrease the frequency and intensity of vasomotor symptoms can offer significant help too. This paper reviews the current state of research in order to assess the options for the treatment of hot flushes in breast cancer survivors.
Managing Hot Flushes in Menopausal Women: A Review.
Mallhi, Tauqeer Hussain; Khan, Yusra Habib; Khan, Amer Hayat; Mahmood, Qaisar; Khalid, Syed Haroon; Saleem, Mohammad
2018-06-01
Hot flushes during menopause are distressing for women and result in poor quality of life. Purpose of the current review was to evaluate the available treatment modalities that should be utilised for the management of hot flushes. Menopause refers to last menses of women life and can be declared after amenorrhea of 12 months. Vasomotor symptoms including hot flushes and night sweats are common after menopause, affecting almost 50 - 85% women older than 45 years. The mean increment in core body and skin temperature is 0.5°C and 0.25 - 3°C during a hot flush attack. Low level of estrogen during menopause and its association in triggering episodes of hot flushes, is still under debate. The most accepted hypothesis is a narrowing of the thermoneutral zone (TNZ) triggered by estrogen fluctuations. Although, hormone replacement therapy (HRT) remains the standard treatment for the alleviation of such symptoms, incidence of life threatening side effects restrained medical professionals from its use. Complications associated with the use of HRT can be avoided by appropriate evaluation of patients before initiating therapy. Several guidelines have also recommended HRT (estrogen and progesterone) to be safe for up to a period of seven years. Both hormonal and non-hormonal treatments are used for the management of hot flushes. Since hot flushes are the least appreciated and neglected complication of menopause, current review provides detailed information on its background, pathophysiology and management, and emphasises the need of its treatment.
NASA Astrophysics Data System (ADS)
Ocampo, Carlos J.; Oldham, Carolyn E.; Sivapalan, Murugesu; Turner, Jeffrey V.
2006-12-01
Deciphering the connection between streamflows and nitrate (NO-3) discharge requires identification of the various water flow pathways within a catchment, and the different time-scales at which hydrological and biogeochemical processes occur. Despite the complexity of the processes involved, many catchments around the world present a characteristic flushing response of NO-3 export. Yet the controls on the flushing response, and how they vary across space and time, are still not clearly understood. In this paper, the flushing response of NO-3 export from a rural catchment in Western Australia was investigated using isotopic (deuterium), chemical (chloride, NO-3), and hydrometric data across different antecedent conditions and time-scales. The catchment streamflow was at all time-scales dominated by a pre-event water source, and the NO-3 discharge was correlated with the magnitude of areas contributing to saturation overland flow. The NO-3 discharge also appeared related to the shallow groundwater dynamics. Thus, the antecedent moisture condition of the catchment at seasonal and interannual time-scales had a major impact on the NO-3 flushing response. In particular, the dynamics of the shallow ephemeral perched aquifer drove a shift from hydrological controls on NO-3 discharge during the early flushing stage to an apparent biogeochemical control on NO-3 discharge during the steady decline stage of the flushing response. This temporally variable control hypothesis provides a new and alternative description of the mechanisms behind the commonly seen flushing response. Copyright
Effect of lavender aromatherapy on menopause hot flushing: A crossover randomized clinical trial.
Kazemzadeh, Rafat; Nikjou, Roya; Rostamnegad, Masoumeh; Norouzi, Hosein
2016-09-01
Flushing is generally considered to be the primary symptom of menopause and is typically the most common complaint in menopausal women. Although flushing poses no danger to a woman's health, it decreases the quality of life. Thus, the purpose of this study was to determine the effect of lavender aromatherapy on menopause flushing. This double-blinded crossover clinical trial included 100 menopausal women 45-55 years of age who were referred to various health centers in Ardabil, Iran in 2013-2014. Samples were blocked randomly and divided into two intervention (lavender) and control (diluted milk) groups. Lavender aroma was smelled for 20 minutes twice a day, over a 12-week period. Data were collected using a demographic questionnaire, and flushing numbers were duly recorded. Data analysis was performed by SPSS version 16 (SPSS Inc., Chicago, IL, USA) using the Chi-square and t test. The results of our investigation showed that both groups had no significant difference according to demographic characteristics (p > 0.05). Additionally, the flushing number significantly decreased in the intervention group than in the control group (p < 0.001). This study indicated that the use of lavender aromatherapy reduced menopause flushing. Given the impact of stress on flushing and the undesirable effects of menopause symptoms on the quality of life, it would appear that this simple, noninvasive, safe, and effective method can be used by menopausal women with noticeable benefits. Copyright © 2016. Published by Elsevier Taiwan LLC.
46 CFR 194.15-11 - Flushing systems.
Code of Federal Regulations, 2012 CFR
2012-10-01
..., AND CONTROL OF EXPLOSIVES AND OTHER HAZARDOUS MATERIALS Chemistry Laboratory and Scientific Laboratory § 194.15-11 Flushing systems. (a) Working spaces in which chemical stores are used shall be equipped with a fresh water supply shower. (b) There shall be a provision for flushing away chemical spills. ...
46 CFR 194.15-11 - Flushing systems.
Code of Federal Regulations, 2014 CFR
2014-10-01
..., AND CONTROL OF EXPLOSIVES AND OTHER HAZARDOUS MATERIALS Chemistry Laboratory and Scientific Laboratory § 194.15-11 Flushing systems. (a) Working spaces in which chemical stores are used shall be equipped with a fresh water supply shower. (b) There shall be a provision for flushing away chemical spills. ...
46 CFR 194.15-11 - Flushing systems.
Code of Federal Regulations, 2011 CFR
2011-10-01
..., AND CONTROL OF EXPLOSIVES AND OTHER HAZARDOUS MATERIALS Chemistry Laboratory and Scientific Laboratory § 194.15-11 Flushing systems. (a) Working spaces in which chemical stores are used shall be equipped with a fresh water supply shower. (b) There shall be a provision for flushing away chemical spills. ...
Automatic Flushing Unit With Cleanliness Monitor
NASA Technical Reports Server (NTRS)
Hildebrandt, N. E.
1982-01-01
Liquid-level probe kept clean, therefore at peak accuracy, by unit that flushes probe with solvent, monitors effluent for contamination, and determines probe is particle-free. Approach may be adaptable to industrial cleaning such as flushing filters and pipes, and ensuring that manufactured parts have been adequately cleaned.
30 CFR 71.400 - Bathing facilities; change rooms; sanitary flush toilet facilities.
Code of Federal Regulations, 2012 CFR
2012-07-01
... WORK AREAS OF UNDERGROUND COAL MINES Surface Bathing Facilities, Change Rooms, and Sanitary Flush Toilet Facilities at Surface Coal Mines § 71.400 Bathing facilities; change rooms; sanitary flush toilet... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Bathing facilities; change rooms; sanitary...
30 CFR 71.400 - Bathing facilities; change rooms; sanitary flush toilet facilities.
Code of Federal Regulations, 2013 CFR
2013-07-01
... WORK AREAS OF UNDERGROUND COAL MINES Surface Bathing Facilities, Change Rooms, and Sanitary Flush Toilet Facilities at Surface Coal Mines § 71.400 Bathing facilities; change rooms; sanitary flush toilet... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Bathing facilities; change rooms; sanitary...
30 CFR 71.400 - Bathing facilities; change rooms; sanitary flush toilet facilities.
Code of Federal Regulations, 2014 CFR
2014-07-01
... WORK AREAS OF UNDERGROUND COAL MINES Surface Bathing Facilities, Change Rooms, and Sanitary Flush Toilet Facilities at Surface Coal Mines § 71.400 Bathing facilities; change rooms; sanitary flush toilet... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Bathing facilities; change rooms; sanitary...
30 CFR 71.400 - Bathing facilities; change rooms; sanitary flush toilet facilities.
Code of Federal Regulations, 2011 CFR
2011-07-01
... WORK AREAS OF UNDERGROUND COAL MINES Surface Bathing Facilities, Change Rooms, and Sanitary Flush Toilet Facilities at Surface Coal Mines § 71.400 Bathing facilities; change rooms; sanitary flush toilet... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Bathing facilities; change rooms; sanitary...
GATE AND VACUUM FLUSHING OF SEWER SEDIMENT: LABORATORY TESTING
The objective of this study was to test the performance of a traditional gate-flushing device and a newly-designed vacuum-flushing device in removing sediment from combined sewers and CSO storage tanks. A laboratory hydraulic flume was used to simulate a reach of sewer or storag...
30 CFR 56.7807 - Flushing the combustion chamber.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Flushing the combustion chamber. 56.7807 Section 56.7807 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND... Rotary Jet Piercing Rotary Jet Piercing § 56.7807 Flushing the combustion chamber. The combustion chamber...
30 CFR 56.7807 - Flushing the combustion chamber.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Flushing the combustion chamber. 56.7807 Section 56.7807 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND... Rotary Jet Piercing Rotary Jet Piercing § 56.7807 Flushing the combustion chamber. The combustion chamber...
30 CFR 56.7807 - Flushing the combustion chamber.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Flushing the combustion chamber. 56.7807 Section 56.7807 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND... Rotary Jet Piercing Rotary Jet Piercing § 56.7807 Flushing the combustion chamber. The combustion chamber...
This research study included an extensive literature review on existing sewer sediment flushing technologies. An innovative vacuum flush system previously developed by the U.S. EPA was tested under laboratory conditions. The tests revealed a strong correlation between the strengt...
A pilot-scale field experiment was conducted to compare the remediation effectiveness of an enhanced-solubilization technique to that of water flushing for removal of multicomponent nonaqueous-phase organic liquid (NAPL) contaminants form a phreatic aquifer. This innovative remed...
SEWER SEDIMENT GATE AND VACUUM FLUSHING TANKS: LABORATORY FLUME STUDIES
The objective of this study was to test the performance of a traditional gate-flushing device and a newly designed vacuum-flushing device in removing sediments from combined sewers and CSO storage tanks. A laboratory hydraulic flune was used to simulate a reach of sewer or storag...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Maienschein, J.L.; Garcia, F.; Garza, R.G.
Tritium-handling apparatus has been decontaminated as part of the downsizing of the LLNL Tritium Facility. Two stainless-steel glove boxes that had been used to process lithium deuteride-tritide (LiDT) slat were decontaminated using the Portable Cleanup System so that they could be flushed with room air through the facility ventilation system. In this paper the details on the decontamination operation are provided. A series of metal (palladium and vanadium) hydride storage beds have been drained of tritium and flushed with deuterium, in order to remove as much tritium as possible. The bed draining and flushing procedure is described, and a calculationalmore » method is presented which allows estimation of the tritium remaining in a bed after it has been drained and flushed. Data on specific bed draining and flushing are given.« less
Stevens, R B; Skorupa, J Y; Rigley, T H; Yannam, G R; Nielsen, K J; Schriner, M E; Skorupa, A J; Murante, A; Holdaway, E; Wrenshall, L E
2009-05-01
Histidine-Tryptophan-Ketoglutarate (HTK) solution is increasingly used to flush and preserve organ donor kidneys, with efficacy claimed equivalent to University of Wisconsin (UW) solution. We observed and reported increased graft pancreatitis in pancreata flushed with HTK solution, which prompted this review of transplanting HTK-flushed kidneys. We analyzed outcomes of deceased-donor kidneys flushed with HTK and UW solutions with a minimum of 12 months follow-up, excluding pediatric and multi-organ recipients. We evaluated patient and graft survival and rejection rates, variables that might constitute hazards to graft survival and renal function. Two-year patient survival, rejection, renal function and graft survival were not different, but early graft loss (<6 months) was worse in HTK-flushed kidneys (p < 0.03). A Cox analysis of donor grade, cold ischemic time, panel reactive antibodies (PRA), donor race, first vs. repeat transplant, rejection and flush solution showed that only HTK use predicted early graft loss (p < 0.04; relative risk = 3.24), almost exclusively attributable to primary non-function (HTK, n = 5 (6.30%); UW, n = 1 (0.65%); p = 0.02). Delayed graft function and early graft loss with HTK occurred only in lesser grade kidneys, suggesting it should be used with caution in marginal donors.
de Jager, Andrew D; Bailey, Neville L
2011-09-01
A rapid LC-MS/MS method for confirmatory testing of five major categories of drugs of abuse (amphetamine-type substances, opiates, cocaine, cannabis metabolites and benzodiazepines) in urine has been developed. All drugs of abuse mandated by the Australian/New Zealand Standard AS/NZS 4308:2008 are quantified in a single chromatographic run. Urine samples are diluted with a mixture of isotope labelled internal standards. An on-line trap-and-flush approach, followed by LC-ESI-MS/MS has been successfully used to process samples in a functioning drugs of abuse laboratory. Following injection of diluted urine samples, compounds retained on the trap cartridge are flushed onto a reverse-phase C18 HPLC column (5-μm particle size) with embedded hydrophylic functionality. A total chromatographic run-time of 15 min is required for adequate resolution. Automated quantitation software algorithms have been developed in-house using XML scripting to partially automate the identification of positive samples, taking into account ion ratio (IR) and retention times (Rt). The sensitivity of the assay was found to be adequate for the quantitation of drugs in urine at and below the confirmation cut-off concentrations prescribed by AS/NZS 4308:2008. Copyright © 2011 Elsevier B.V. All rights reserved.
Flush Airdata Sensing (FADS) System Calibration Procedures and Results for Blunt Forebodies
NASA Technical Reports Server (NTRS)
Cobleigh, Brent R.; Whitmore, Stephen A.; Haering, Edward A., Jr.; Borrer, Jerry; Roback, V. Eric
1999-01-01
Blunt-forebody pressure data are used to study the behavior of the NASA Dryden Flight Research Center flush airdata sensing (FADS) pressure model and solution algorithm. The model relates surface pressure measurements to the airdata state. Spliced from the potential flow solution for uniform flow over a sphere and the modified Newtonian impact theory, the model was shown to apply to a wide range of blunt-forebody shapes and Mach numbers. Calibrations of a sphere, spherical cones, a Rankine half body, and the F-14, F/A-18, X-33, X-34, and X-38 configurations are shown. The three calibration parameters are well-behaved from Mach 0.25 to Mach 5.0, an angle-of-attack range extending to greater than 30 deg, and an angle-of-sideslip range extending to greater than 15 deg. Contrary to the sharp calibration changes found on traditional pitot-static systems at transonic speeds, the FADS calibrations are smooth, monotonic functions of Mach number and effective angles of attack and sideslip. Because the FADS calibration is sensitive to pressure port location, detailed measurements of the actual pressure port locations on the flight vehicle are required and the wind-tunnel calibration model should have pressure ports in similar locations. The procedure for calibrating a FADS system is outlined.
NASA Astrophysics Data System (ADS)
Alsevska, A.; Dilendorfs, V.; Spolitis, S.; Bobrovs, Vj.
2017-12-01
In the paper, the authors compare efficiency of two physical dispersion compensation methods for single channel and 8-channel WDM fibre-optical transmission systems using return-to-zero (RZ) and non-return-to-zero (NRZ) line codes for operation within optical C-band frequencies by means of computer simulations. As one of the most important destructive effects in fibre optical transmission systems (FOTS) is chromatic dispersion (CD), it is very important to reduce its negative effect on a transmitted signal. Dispersion compensation methods that were implemented in the research were dispersion compensating fibre (DCF) and fibre Bragg grating (FBG). The main goal of the paper was to find out which dispersion compensation method (DCF or FBG) provided the highest performance increase for fibre-optical transmission system and provided the longest transmission distance after dispersion compensation was implemented at different locations in the fibre-optical line while RZ or NRZ line codes were used. In the paper the reference point of signal quality for all measurements, which were obtained at the receiver, was BER<10-12.
Laser velocimetry with fluorescent dye-doped polystyrene microspheres.
Lowe, K Todd; Maisto, Pietro; Byun, Gwibo; Simpson, Roger L; Verkamp, Max; Danehy, Paul M; Tiemsin, Pacita I; Wohl, Christopher J
2013-04-15
Simultaneous Mie scattering and laser-induced fluorescence (LIF) signals are obtained from individual polystyrene latex microspheres dispersed in an air flow. Microspheres less than 1 μm mean diameter were doped with two organic fluorescent dyes, Rhodamine B (RhB) and dichlorofluorescein (DCF), intended either to provide improved particle-based flow velocimetry in the vicinity of surfaces or to provide scalar flow information (e.g., marking one of two fluid streams). Both dyes exhibit measureable fluorescence signals that are on the order of 10(-3) to 10(-4) times weaker than the simultaneously measured Mie signals. It is determined that at the conditions measured, 95.5% of RhB LIF signals and 32.2% of DCF signals provide valid laser-Doppler velocimetry measurements compared with the Mie scattering validation rate with 6.5 W of 532 nm excitation, while RhB excited with 1.0 W incident laser power still exhibits 95.4% valid velocimetry signals from the LIF channel. The results suggest that the method is applicable to wind tunnel measurements near walls where laser flare can be a limiting factor and monodisperse particles are essential.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pope, G.A.; Sepehrnoori, K.
1995-12-31
The objective of this research is to develop cost-effective surfactant flooding technology by using simulation studies to evaluate and optimize alternative design strategies taking into account reservoir characteristics process chemistry, and process design options such as horizontal wells. Task 1 is the development of an improved numerical method for our simulator that will enable us to solve a wider class of these difficult simulation problems accurately and affordably. Task 2 is the application of this simulator to the optimization of surfactant flooding to reduce its risk and cost. In this quarter, we have continued working on Task 2 to optimizemore » surfactant flooding design and have included economic analysis to the optimization process. An economic model was developed using a spreadsheet and the discounted cash flow (DCF) method of economic analysis. The model was designed specifically for a domestic onshore surfactant flood and has been used to economically evaluate previous work that used a technical approach to optimization. The DCF model outputs common economic decision making criteria, such as net present value (NPV), internal rate of return (IRR), and payback period.« less
NASA Astrophysics Data System (ADS)
Espa, Paolo; Castelli, Elena; Crosa, Giuseppe; Gentili, Gaetano
2013-07-01
Sediment flushing may be effective in mitigating loss of reservoir storage due to siltation, but flushing must be controlled to limit the impact on the downstream environment. A reliable prediction of the environmental effects of sediment flushing is hindered by the limited scientific information currently available. Consequently, there may be some controversy as regards to management decisions, planning the work, and monitoring strategies. This paper summarizes the main results of a monitoring campaign on the stream below a small alpine hydropower reservoir subjected to annual flushing between 2006 and 2009. The removed sediment was essentially silt, and the suspended solid concentration (SSC) of the discharged water was controlled to alleviate downstream impact. Control was achieved through hydraulic regulation and mechanical digging, alternating daytime sediment evacuation, and nocturnal clear water release. The four operations lasted about two weeks each and had an average SSC of about 4 g L-1. Maximum values of SSC were generally kept below 10 g L-1. Downstream impact was quantified through sampling of fish fauna (brown trout) and macroinvertebrate in the final reach of the effluent stream. The benthic community was severely impaired by the flushing operations, but recovered to pre-flushing values in a few months. As expected, the impact on brown trout was heavier on juveniles. While data biasing due to fish removal and re-stocking cannot be ruled out, the fish community seems to have reached a state of equilibrium characterized by a lower density than was measured before the flushing operations.
Espa, Paolo; Castelli, Elena; Crosa, Giuseppe; Gentili, Gaetano
2013-07-01
Sediment flushing may be effective in mitigating loss of reservoir storage due to siltation, but flushing must be controlled to limit the impact on the downstream environment. A reliable prediction of the environmental effects of sediment flushing is hindered by the limited scientific information currently available. Consequently, there may be some controversy as regards to management decisions, planning the work, and monitoring strategies. This paper summarizes the main results of a monitoring campaign on the stream below a small alpine hydropower reservoir subjected to annual flushing between 2006 and 2009. The removed sediment was essentially silt, and the suspended solid concentration (SSC) of the discharged water was controlled to alleviate downstream impact. Control was achieved through hydraulic regulation and mechanical digging, alternating daytime sediment evacuation, and nocturnal clear water release. The four operations lasted about two weeks each and had an average SSC of about 4 g L(-1). Maximum values of SSC were generally kept below 10 g L(-1). Downstream impact was quantified through sampling of fish fauna (brown trout) and macroinvertebrate in the final reach of the effluent stream. The benthic community was severely impaired by the flushing operations, but recovered to pre-flushing values in a few months. As expected, the impact on brown trout was heavier on juveniles. While data biasing due to fish removal and re-stocking cannot be ruled out, the fish community seems to have reached a state of equilibrium characterized by a lower density than was measured before the flushing operations.
von Horn, Kyra; Depenbusch, Marion; Schultze-Mosgau, Askan; Griesinger, Georg
2017-04-01
Is a modified double-lumen aspiration needle system with follicular flushing able to increase the mean oocyte yield by at least one in poor response IVF patients as compared to single-lumen needle aspiration without flushing? Follicular flushing with the modified flushing system did not increase the number of oocytes, but increased the procedure duration. Most studies on follicular flushing were performed with conventional double-lumen needles in patients who were normal responders. Overall, these studies indicated no benefit of follicular flushing. Prospective, single-centre, randomized, controlled, open, superiority trial comparing the 17 G Steiner-Tan Needle® flushing system with a standard 17 G single-lumen aspiration needle (Gynetics®); time frame February 2015-March 2016. Eighty IVF patients, 18-45 years, BMI >18 kg/m2 to <35 kg/m2, presenting with ≤ five follicles >10 mm in both ovaries at the end of the follicular phase were randomized to either aspirating and flushing each follicle 3× with the Steiner-Tan-Needle® automated flushing system (n = 40) or a conventional single-lumen needle aspiration (n = 40). Primary outcome was the number of cumulus-oocyte-complexes (COCs). Procedure duration, burden (Depression Anxiety and Stress Scale; DASS-21) and post-procedure pain were also assessed. Flushing was not superior with a mean (SD) number of COCs of 2.4 (2.0) and 3.1 (2.3) in the Steiner-Tan Needle® and in the Gynectics® group, respectively (mean difference -0.7, 95% CI: 0.3 to -1.6; P = 0.27). Likewise no differences were observed in metaphase II oocytes, two pronuclear oocytes, number of patients having an embryo transfer and DASS 21 scores. The procedure duration was significantly 2-fold increased. Testing for differences in the number of patients achieving an embryo transfer or differences in pregnancy rate would require a much larger sample size. The use of follicular flushing is unlikely to benefit the prognosis of patients with poor ovarian response. The Steiner-Tan Needles® and the flushing system were provided for free by the manufacturer. K.v.H. has received personal fees from Finox and non-financial support from Merck-Serono; M.D. has received personal fees from Finox and non-financial support from Merck-Serono. A.S.-M. has received personal fees and non-financial support from M.D., Ferring, Merck-Serono, Finox, TEVA. G.G. has received personal fees and non-financial support from M.D., Ferring, Merck-Serono, Finox, TEVA, IBSA, Glycotope, as well as personal fees from VitroLife, NMC Healthcare LLC, ReprodWissen LLC and ZIVA LLC. NCT 02365350 (clinicaltrials.gov). Sixth of February 2015. Ninth of February 2015. © The Author 2017. Published by Oxford University Press on behalf of the European Society of Human Reproduction and Embryology. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com
REMOVAL OF TANK AND SEWER SEDIMENT BY GATE FLUSHING: COMPUTATIONAL FLUID DYNAMICS MODEL STUDIES
This presentation will discuss the application of a computational fluid dynamics 3D flow model to simulate gate flushing for removing tank/sewer sediments. The physical model of the flushing device was a tank fabricated and installed at the head-end of a hydraulic flume. The fl...
Use of a double chip seal to correct a flushing hot mix asphalt pavement in Washington State.
DOT National Transportation Integrated Search
2011-04-01
A chip seal constructed on an existing flushed roadway has the potential to result in bleeding or flushing of the new chip seal. The excess binder, if not properly accounted for during design and construction, will migrate to the surface of the chip ...
30 CFR 57.7807 - Flushing the combustion chamber.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Flushing the combustion chamber. 57.7807... and Rotary Jet Piercing Rotary Jet Piercing-Surface Only § 57.7807 Flushing the combustion chamber. The combustion chamber of a jet drill stem which has been sitting unoperated in a drill hole shall be...
30 CFR 57.7807 - Flushing the combustion chamber.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Flushing the combustion chamber. 57.7807... and Rotary Jet Piercing Rotary Jet Piercing-Surface Only § 57.7807 Flushing the combustion chamber. The combustion chamber of a jet drill stem which has been sitting unoperated in a drill hole shall be...
30 CFR 57.7807 - Flushing the combustion chamber.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Flushing the combustion chamber. 57.7807... and Rotary Jet Piercing Rotary Jet Piercing-Surface Only § 57.7807 Flushing the combustion chamber. The combustion chamber of a jet drill stem which has been sitting unoperated in a drill hole shall be...
DOT National Transportation Integrated Search
2016-09-01
A double chip seal was applied to an existing hot mix asphalt (HMA) pavement to mitigate severe flushing that existed throughout the project. Special care was taken to adjust the amount of binder used to account for the degree of flushing in the exis...
Dumas, F; Le Gendre, R; Thomas, Y; Andréfouët, S
2012-01-01
Hydrodynamic functioning and water circulation of the semi-closed deep lagoon of Ahe atoll (Tuamotu Archipelago, French Polynesia) were investigated using 1 year of field data and a 3D hydrodynamical model. Tidal amplitude averaged less than 30 cm, but tide generated very strong currents (2 ms(-1)) in the pass, creating a jet-like circulation that partitioned the lagoon into three residual circulation cells. The pass entirely flushed excess water brought by waves-induced radiation stress. Circulation patterns were computed for climatological meteorological conditions and summarized with stream function and flushing time. Lagoon hydrodynamics and general overturning circulation was driven by wind. Renewal time was 250 days, whereas the e-flushing time yielded a lagoon-wide 80-days average. Tide-driven flush through the pass and wind-driven overturning circulation designate Ahe as a wind-driven, tidally and weakly wave-flushed deep lagoon. The 3D model allows studying pearl oyster larvae dispersal in both realistic and climatological conditions for aquaculture applications. Copyright © 2012 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Hildebrand, E. P.
2017-12-01
Air Force Weather has developed various cloud analysis and forecast products designed to support global Department of Defense (DoD) missions. A World-Wide Merged Cloud Analysis (WWMCA) and short term Advected Cloud (ADVCLD) forecast is generated hourly using data from 16 geostationary and polar-orbiting satellites. Additionally, WWMCA and Numerical Weather Prediction (NWP) data are used in a statistical long-term (out to five days) cloud forecast model known as the Diagnostic Cloud Forecast (DCF). The WWMCA and ADVCLD are generated on the same polar stereographic 24 km grid for each hemisphere, whereas the DCF is generated on the same grid as its parent NWP model. When verifying the cloud forecast models, the goal is to understand not only the ability to detect cloud, but also the ability to assign it to the correct vertical layer. ADVCLD and DCF forecasts traditionally have been verified using WWMCA data as truth, but this might over-inflate the performance of those models because WWMCA also is a primary input dataset for those models. Because of this, in recent years, a WWMCA Reanalysis product has been developed, but this too is not a fully independent dataset. This year, work has been done to incorporate data from external, independent sources to verify not only the cloud forecast products, but the WWMCA data itself. One such dataset that has been useful for examining the 3-D performance of the cloud analysis and forecast models is Atmospheric Radiation Measurement (ARM) data from various sites around the globe. This presentation will focus on the use of the Department of Energy (DoE) ARM data to verify Air Force Weather cloud analysis and forecast products. Results will be presented to show relative strengths and weaknesses of the analyses and forecasts.
Shah, Manish A; Jhawer, Minaxi; Ilson, David H; Lefkowitz, Robert A; Robinson, Edric; Capanu, Marinela; Kelsen, David P
2011-03-01
To evaluate the safety and efficacy of a modified administration schedule of docetaxel, cisplatin, and fluorouracil (mDCF) with bevacizumab in patients with advanced gastroesophageal malignancies. Previously untreated patients with metastatic gastroesophageal adenocarcinoma received bevacizumab 10 mg/kg, docetaxel 40 mg/m², fluorouracil 400 mg/m², leucovorin 400 mg/m² on day 1, fluorouracil 1,000 mg/m²/d × 2 days intravenous continuous infusion beginning on day 1, and cisplatin 40 mg/m² on day 3. The primary objective was to improve 6-month progression-free survival (PFS) from 43% (historical DCF control) to 63% with the addition of bevacizumab. The target accrual was 44 patients to have 10% type I and II error rates. In total, 44 eligible patients with cancer were enrolled from October 2006 to October 2008: 22 gastric, 20 gastroesophageal junction (GEJ), and two esophagus. In 39 patients with measurable disease, the confirmed response rate was 67% (95% CI, 50% to 81%). Six-month PFS was 79% (95% CI, 63% to 88%), and median PFS was 12 months (95% CI, 8.8 to 18.2 months). With 26-month follow-up, median overall survival (OS) was 16.8 months (95% CI, 12.1 to 26.1 months), and 2-year survival was 37%. Treatment-related grade 3 to 4 toxicity was as follows: neutropenia without fever (50%), fatigue (25%), venous thromboembolism (39%), and nausea, vomiting, mucositis, neuropathy, and febrile neutropenia less than 10% each. In subset analysis, diffuse gastric cancer had significantly worse PFS and OS, and the response rate in proximal/GEJ tumors was 85% (95% CI, 62% to 97%). mDCF with bevacizumab appears tolerable and has notable patient outcomes in patients with advanced gastroesophageal adenocarcinoma. Six-month PFS was 79%, surpassing our predefined efficacy end point, and median and 2-year OS were 16.8 months and 37%, respectively.
Shah, Manish A.; Jhawer, Minaxi; Ilson, David H.; Lefkowitz, Robert A.; Robinson, Edric; Capanu, Marinela; Kelsen, David P.
2011-01-01
Purpose To evaluate the safety and efficacy of a modified administration schedule of docetaxel, cisplatin, and fluorouracil (mDCF) with bevacizumab in patients with advanced gastroesophageal malignancies. Patients and Methods Previously untreated patients with metastatic gastroesophageal adenocarcinoma received bevacizumab 10 mg/kg, docetaxel 40 mg/m2, fluorouracil 400 mg/m2, leucovorin 400 mg/m2 on day 1, fluorouracil 1,000 mg/m2/d × 2 days intravenous continuous infusion beginning on day 1, and cisplatin 40 mg/m2 on day 3. The primary objective was to improve 6-month progression-free survival (PFS) from 43% (historical DCF control) to 63% with the addition of bevacizumab. The target accrual was 44 patients to have 10% type I and II error rates. Results In total, 44 eligible patients with cancer were enrolled from October 2006 to October 2008: 22 gastric, 20 gastroesophageal junction (GEJ), and two esophagus. In 39 patients with measurable disease, the confirmed response rate was 67% (95% CI, 50% to 81%). Six-month PFS was 79% (95% CI, 63% to 88%), and median PFS was 12 months (95% CI, 8.8 to 18.2 months). With 26-month follow-up, median overall survival (OS) was 16.8 months (95% CI, 12.1 to 26.1 months), and 2-year survival was 37%. Treatment-related grade 3 to 4 toxicity was as follows: neutropenia without fever (50%), fatigue (25%), venous thromboembolism (39%), and nausea, vomiting, mucositis, neuropathy, and febrile neutropenia less than 10% each. In subset analysis, diffuse gastric cancer had significantly worse PFS and OS, and the response rate in proximal/GEJ tumors was 85% (95% CI, 62% to 97%). Conclusion mDCF with bevacizumab appears tolerable and has notable patient outcomes in patients with advanced gastroesophageal adenocarcinoma. Six-month PFS was 79%, surpassing our predefined efficacy end point, and median and 2-year OS were 16.8 months and 37%, respectively. PMID:21189380
Huang, Jin; Hu, Huabin; Xie, Yangchun; Tang, Youhong; Liu, Wei; Zhong, Meizuo
2013-06-01
To analyze the impact of β-tubulin-III (TUBB3), thymidylate synthase (TS) and excision repair cross complementation group 1 (ERCC1) mRNA expression on chemoresponse and clinical outcome of patients with advanced gastric cancer treated with TXT/CDDP/FU (DCF) regimen chemotherapy. The study population consisted of 48 patients with advanced gastric cancer. All patients were treated with DCF regimen palliative chemotherapy. The mRNA expressions of TUBB3, TS and ERCC1 of primary tumors were examined by multiplex branched-DNA liquid chip technology. The patients with low TUBB3 mRNA expression had higher response rate to chemotherapy than patients with high TUBB3 expression (P=0.011). There were no significant differences between response rate and TS or ERCC1 expression pattern. Median overall survival (OS) and median time to progression (TTP) were significantly longer in patients with low TUBB3 mRNA expression (P=0.002, P<0.001). TS or ERCC1 expression was not correlated with TTP and OS. In the combined analysis including TUBB3, TS and ERCC1, the patients with 0 or 1 high expression gene had better response rate, TTP and OS than the remaining patients (all P<0.001). Multivariate analysis revealed that ECOG (Eastern Cooperative Oncology Group)≥2 (HR=2.42, P=0.009) and TUBB3 (HR=2.34, P=0.036) mRNA expression significantly impacted on OS. High TUBB3 mRNA expression is correlated with resistance to DCF regimen chemotherapy. TUBB3 might be a predictive and prognostic factor in patients with advanced gastric cancer treated with TXT-based chemotherapy. The combined evaluation of TUBB3, TS and ERCC1 expression can promote the individual treatment in advanced gastric cancer.
NASA Astrophysics Data System (ADS)
Diehl, Tobias; Singer, Julia; Hetényi, György; Grujic, Djordje; Clinton, John; Giardini, Domenico; Kissling, Edi
2017-04-01
The instrumental seismicity of Bhutan is characterized by a lower activity compared to most other parts of the Himalayan arc. To understand this low activity and its impact on the seismic hazard, a seismic network was installed in Bhutan for 22 months between 2013 and 2014. From the recorded seismicity, earthquake moment tensors, and local earthquake tomography, we reveal along-strike variations in structure and crustal deformation regime. Imaged structural variations, primarily a thickened crust in western Bhutan, suggest lateral differences in stresses on the Main Himalayan Thrust (MHT), potentially affecting interseismic coupling and style of deformation. Sikkim, western Bhutan, and its foreland are characterized by strike-slip faulting in the Indian basement. Strain is particularly localized along a NW-SE striking dextral fault zone reaching from Chungthang in northeast Sikkim to Dhubri at the northwestern edge of the Shillong Plateau in the foreland. The dextral Dhubri-Chungthang fault zone (DCF) might segment the MHT between eastern Nepal and western Bhutan and connect the deformation front of the Himalaya with the Shillong Plateau in the foreland by forming the western boundary of a West-Assam block. In contrast, the eastern boundary of this block, hitherto associated with the Kopili foreland fault, appears to be diffuse. In eastern Bhutan, we image a seismogenic, flat portion of the MHT, which might be related to a partially creeping fault segment or increased background seismicity originating from the 2009 MW6.1 earthquake. In western-central Bhutan, clusters of micro-earthquakes at the front of the High-Himalayas indicate the presence of a mid-crustal ramp and stress buildup on a fully coupled MHT. The area bounded by the DCF in the west and the seismogenic MHT in the east has the potential for M7-8 earthquakes in Bhutan. Similarly, the DCF has the potential to host M7 earthquakes beneath the densely populated foreland basin as documented by the Dhubri earthquake of 1930, which is likely associated to this structure.
NASA Astrophysics Data System (ADS)
Diehl, Tobias; Singer, Julia; Hetényi, György; Grujic, Djordje; Clinton, John; Giardini, Domenico; Kissling, Edi; Gansser Working Group
2017-08-01
The instrumental record of Bhutan is characterized by a lower seismicity compared to other parts of the Himalayan arc. To understand this low activity and its impact on the seismic hazard, a seismic network was installed in Bhutan for 22 months between 2013 and 2014. Recorded seismicity, earthquake moment tensors and local earthquake tomography reveal along-strike variations in structure and crustal deformation regime. A thickened crust imaged in western Bhutan suggests lateral differences in stresses on the Main Himalayan Thrust (MHT), potentially affecting the interseismic coupling and deformation regime. Sikkim, western Bhutan and its foreland are characterized by strike-slip faulting in the Indian basement. Strain is particularly localized along a NW-SE striking mid-crustal fault zone reaching from Chungthang in northeast Sikkim to Dhubri at the northwestern edge of the Shillong Plateau in the foreland. The dextral Dhubri-Chungthang fault zone (DCF) causes segmentation of the Indian basement and the MHT between eastern Nepal and western Bhutan and connects the deformation front of the Himalaya with the Shillong Plateau by forming the western boundary of the Shillong block. The Kopili fault, the proposed eastern boundary of this block, appears to be a diffuse zone of mid-crustal seismicity in the foreland. In eastern Bhutan we image a seismogenic, flat portion of the MHT, which might be either related to a partially creeping segment or to increased background seismicity originating from the 2009 MW 6.1 earthquake. In western-central Bhutan clusters of micro-earthquakes at the front of the High-Himalayas indicate the presence of a mid-crustal ramp and stress buildup on a fully coupled MHT. The area bounded by the DCF in the west and the seismogenic MHT in the east has the potential for M7-8 earthquakes in Bhutan. Similarly, the DCF has the potential to host M7 earthquakes as documented by the 2011 Sikkim and the 1930 Dhubri earthquakes, which were potentially associated with this structure.
NASA Astrophysics Data System (ADS)
Razansky, R. Nika; Rozental, Amir; Mueller, Mathias S.; Deliolanis, Nikolaos; Jaffer, Farouc A.; Koch, Alexander W.; Ntziachristos, Vasilis
2011-03-01
Early detection of high-risk coronary atherosclerosis remains an unmet clinical challenge. We have previously demonstrated a near-infrared fluorescence catheter system for two-dimensional intravascular detection of fluorescence molecular probes [1]. In this work we improve the system performance by introducing a novel high resolution sensor. The main challenge of the intravascular sensor is to provide a highly focused spot at an application relevant distance on one hand and a highly efficient collection of emitted light on the other. We suggest employing a double cladding optical fiber (DCF) in combination with focusing optics to provide a sensor with both highly focused excitation light and highly efficient fluorescent light collection. The excitation laser is coupled into the single mode core of DCF and guided through a focusing element and a right angle prism. The resulting side-fired beam exhibits a small spot diameter (50 μm) throughout a distance of up to 2 mm from the sensor. This is the distance of interest for intravascular coronary imaging application, determined by an average human coronary artery diameter. At the blood vessel wall, an activatable fluorescence molecular probe is excited in the diseased lesions. Next light of slightly shifted wavelength emits only in the places of the inflammations, associated with dangerous plaques [2]. The emitted light is collected by the cladding of the DCF, with a large collection angle (NA=0.4). The doublecladding acts as multimodal fiber and guides the collected light to the photo detection elements. The sensor automatically rotates and pulled-back, while each scanned point is mapped according to the amount of detected fluorescent emission. The resulting map of fluorescence activity helps to associate the atherosclerotic plaques with the inflammation process. The presented detection system is a valuable tool in the intravascular plaque detection and can help to differentiate the atherosclerotic plaques based on their biological activity, identify the ones that prone to rupture and therefore require more medical attention.
Forsberg, H; Eriksson, U J; Melefors, O; Welsh, N
1998-02-01
Embryonic dysmorphogenesis has been blocked by antioxidant treatment in vivo and in vitro, suggesting that embryonic excess of reactive oxygen species (ROS) has a role in the teratogenic process of diabetic pregnancy. We report that the basal levels of ROS in dispersed rat embryonic cells in vitro, as determined by fluorescence of dichlorofluorescein (DCF), were not different in cells from control and diabetic pregnancy at day 10 or 12. Beta-hydroxybutyrate (beta-HB) and succinic acid monomethyl ester both augmented DCF fluorescence in cells from day 12 embryos of normal and diabetic rats but not from day 10 embryos. Cells of day 10 and day 12 embryos from normal and diabetic rats responded to increasing glucose concentrations with a dosage-dependent alleviation of DCF fluorescence. Day 10 embryonic cells exhibited high glucose utilization rates and high pentose phosphate shunt rates, but low mitochondrial oxidation rates. Moreover, in vitro culture of embryos between gestational days 9 and 10 in the presence of 20% oxygen induced an increased and glucose-sensitive oxidation of glucose compared with embryos not cultured in vitro. At gestation day 12, however, pentose phosphate shunt rates showed a decrease, whereas the mitochondrial beta-HB oxidation rates were increased compared with those at gestation day 10. This was paralleled by a lower expression of glucose 6-phosphate dehydrogenase- and phosphofructokinase-mRNA levels at day 12 than at day 10. On the other hand, H-ferritin mRNA expression at day 12 was high compared with day 10. None of the mRNA species investigated were affected by the diabetic state of the mother. It was concluded that beta-HB-induced stimulation of mitochondrial oxidative events may lead to the generation of ROS at gestational day 12, but probably not at day 10, when only a minute amount of mitochondrial activity occurs. Thus our results do not support the notion of diabetes-induced mitochondrial oxidative stress before the development of a placental supply of oxygen.
On sampling biases arising from insufficient bottle flushing
NASA Astrophysics Data System (ADS)
Codispoti, L. A.; Paver, C. R.
2016-02-01
Collection of representative water samples using carousel bottles is important for accurately determining biological and chemical gradients. The development of more technologically advanced instrumentation and sampling apparatus causes sampling packages to increase and "soak times" to decrease, increasing the probability that insufficient bottle flushing will produce biased results. Qualitative evidence from various expeditions suggest that insufficient flushing may be a problem. Here we report on multiple field experiments that were conducted to better quantify the errors that can arise from insufficient bottle flushing. Our experiments suggest that soak times of more than 2 minutes are sometimes required to collect a representative sample.
Inhibition of soluble epoxide hydrolase limits niacin-induced vasodilation in mice
Inceoglu, A. B.; Clifton, H.L.; Yang, J.; Hegedus, C.; Hammock, B. D.; Schaefer, S.
2012-01-01
Background The use of niacin in the treatment of dyslipidemias is limited by the common side effect of cutaneous vasodilation, commonly termed flushing. Flushing is thought to be due to release of the vasodilatory prostanoids PGD2 and PGE2 from arachidonic acid metabolism through the cyclooxygenase (COX) pathway. Arachidonic acid is also metabolized by the cytochrome P450 system which is regulated, in part, by the enzyme soluble epoxide hydrolase (sEH). Methods: These experiments used an established murine model in which ear tissue perfusion was measured by laser Doppler to test the hypothesis that inhibition of sEH would limit niacin-induced flushing. Results: Niacin-induced flushing was reduced from 506 ± 126 to 213 ± 39 % in sEH knockout animals. Pharmacologic treatment with 3 structurally distinct sEH inhibitors similarly reduced flushing in a dose dependent manner, with maximal reduction to 143±15% of baseline flow using a concentration of 1 mg/kg TPAU (1-trifluoromethoxyphenyl-3-(1-acetylpiperidin-4-yl) urea). Systemically administered PGD2 caused ear vasodilation which was not changed by either pharmacologic sEH inhibition or by sEH gene deletion. Conclusions: Inhibition of sEH markedly reduces niacin-induced flushing in this model without an apparent effect on the response to PGD2. sEH inhibition may be a new therapeutic approach to limit flushing in humans. PMID:22526297
Newman, Ian M; Ding, Lanyan; Shell, Duane F; Lin, Lida
2017-06-09
Alcohol-related facial flushing is a sign of compromised alcohol metabolism and increased risk of certain cancers. This project examined how facial flushing might be used to reduce alcohol use to lower cancer risks. Interviews with Chinese university students identified gender, friendship, and drinking purpose as important variables related to whether someone would encourage a person who flushes when drinking alcohol to stop or reduce their drinking. A questionnaire was developed that incorporated these variables into 24 drinking scenarios in which someone flushed while drinking. Students responded whether they would (a) encourage the flusher to stop or drink less; (b) do nothing while wishing they could; or (c) do nothing because there was no need. Analysis of survey responses from 2912 university students showed a three-way interaction of the variables and implied that the probability students will intervene when a drinker flushes was highest when the flusher was a female, a close friend, and the drinking purpose was for fun and lowest if the flusher was a male, the friendship was general, and the drinking purpose was risky. The results provide important details about the social factors affecting how other people respond to a person who flushes when drinking alcohol. This information is useful for those considering ways to reduce and prevent aerodigestive cancers through education and information programs.
A traditional first flush assessment of E. coli in urban stormwater runoff.
McCarthy, D T
2009-01-01
The behaviour of microorganisms in urban stormwater should be thoroughly investigated and understood to (a) design treatment technologies that can reduce the human health risks of utilising stormwater and (b) develop models which can accurately predict the levels of microorganisms in urban stormwater to aid in health risk assessments. A crucial part of understanding the behaviour of pollutants in urban stormwater is to determine whether the pollutant experiences higher levels in certain portions of the event (e.g. does the pollutant experience a first flush?). The aim of this paper is twofold: (a) determine if the first flush phenomenon exists for a commonly used microbial indicator, Escherichia coli, and (b) determine whether the presence of a first flush is dependent on antecedent climatic and/or hydrologic characteristics. E. coli data collected from the wet weather flows of four urban catchments in Melbourne was used in the paper. Cumulative mass versus volume curves were used in conjunction with standard statistical inferences to determine that the first flush phenomenon was not consistently present, and that the presence and magnitude of a first flush varied considerably between each site. Regression analyses were used to determine that this variation was probably not caused by the same governing processes for all four sites, with different explanatory variables significantly explaining the first flush at each site.
Marshall-McKenna, R; Morrison, A; Stirling, L; Hutchison, C; Rice, A M; Hewitt, C; Paul, L; Rodger, M; Macpherson, I R; McCartney, E
2016-04-01
Quality of life in women receiving adjuvant endocrine therapy for breast cancer (BC) may be impaired by hot flushes and night sweats. The cool pad pillow topper (CPPT) is a commercial product, promoted to improve quality of sleep disrupted by hot flushes. This study aimed to identify if the CPPT reduces severity of sleep disturbance by minimising effects of hot flushes. This randomised phase II trial, recruited women with BC, on adjuvant endocrine therapy, experiencing hot flushes and insomnia. Participants were randomised (stratified by baseline sleep efficiency score (SES) and menopausal status) to the intervention arm (CPPT + standard care) or control arm (standard care). Participants completed Hospital Anxiety and Depression Scale and Functional Assessment of Cancer Therapy-Breast (FACT-B) questionnaires and fortnightly sleep/hot flush diaries (where responses were averaged over 2-week periods). The primary endpoint was change in average SES from -2 to 0 weeks to 2 to 4 weeks. Seventy-four pre- (68.9 %) and post-menopausal (31.1 %) women were recruited. Median age was 49.5 years. Endocrine therapies included tamoxifen (93.2 %). Median SES at weeks 2 to 4 improved in both arms but the increase on the intervention arm was almost twice that on the control arm (p = 0.024). There were significantly greater reductions in hot flushes and HADS depression in the intervention arm (p = 0.09 and p = 0.036, respectively). There were no significant differences in FACT-B or HADS anxiety. This study supports the use of the CPPT as an aid to reduce sleep disturbance and the frequency/severity of hot flushes.
Ueda, Yu; Odunayo, Adesola; Mann, F A
2013-01-01
To determine whether heparinized saline would be more effective in maintaining the patency of peripheral IV catheters in dogs compared to 0.9% sodium chloride. Prospective blinded randomized study. University Veterinary Teaching Hospital. Thirty healthy purpose bred dogs, intended for use in the junior surgery laboratory, were utilized. The dogs were randomized into 1 of 3 groups, 2 treatment groups and a control group. An 18-Ga cephalic catheter was placed in the cephalic vein of each dog. Each dog in the treatment group had their catheter flushed with either 10 IU/mL heparinized saline or 0.9% sodium chloride every 6 hours for 42 hours. The dogs in the control group did not have their catheters flushed until the end of the study period. Immediately prior to flushing catheters, each catheter was evaluated for patency by aspiration of blood and the catheter site was evaluated for phlebitis. All dogs in the heparinized saline and 0.9% sodium chloride group had catheters that flushed easily at each evaluation point. More dogs in the saline group had catheters from which blood could not be aspirated, but there was no significant difference between these groups. All dogs in the control group had catheters that flushed easily at the end of the assigned 6 hour interval except in 1 dog. Phlebitis was not detected in any dog. Flushes of 0.9% sodium chloride were found to be as effective as 10 IU/mL heparinized saline flushes in maintaining patency of 18-Ga peripheral venous catheters in dogs for up to 42 hours. For peripheral catheters placed with the intention of performing serial blood draws, heparinized flushes may be warranted. © Veterinary Emergency and Critical Care Society 2013.
Flushing of a coastal lagoon in the Red Sea
NASA Astrophysics Data System (ADS)
Sultan, S. A. R.; Ahmad, F.
1990-09-01
Shu'aiba Lagoon (Lat. 20°45'N; Long. 39°28'E) is located on the eastern coast of the Red Sea. It is relatively shallow with an area of approximately 11·7 km 2. The inlet to the lagoon is narrow with a cross-sectional area of about 245 m 2. This lagoon is a future site to develop mariculture. With this objective in view the flushing time scale of the lagoon was calculated, as flushing is an important abiotic factor in lagoon ecology. The average flushing time for the months February to June and September to November is about 20 days. Oceanic inputs play an important part in the process of fertilization of the lagoons. The marine environment in arid zone lagoons is under natural stress due to high temperatures and salinities. However, the flushing time scale of 20 days may not exert intolerable stress on the ecology of the Shu'aiba Lagoon.
Ramadan, Bimastyaji Surya; Sari, Gina Lova; Rosmalina, Raden Tina; Effendi, Agus Jatnika; Hadrah
2018-07-15
Combination of electrokinetic soil flushing and bioremediation (EKSF-Bio) technology has attracted many researchers attention in the last few decades. Electrokinetic is used to increase biodegradation rate of microorganisms in soil pores. Therefore, it is necessary to use solubilizing agents such as surfactants that can improve biodegradation process. This paper describes the basic understanding and recent development associated with electrokinetic soil flushing, bioremediation, and its combination as innovative hybrid solution for treating hydrocarbon contaminated soil. Surfactant has been widely used in many studies and practical applications in remediation of hydrocarbon contaminant, but specific review about those combination technology cannot be found. Surfactants and other flushing/solubilizing agents have significant effects to increase hydrocarbon remediation efficiency. Thus, this paper is expected to provide clear information about fundamental interaction between electrokinetic, flushing agents and bioremediation, principal factors, and an inspiration for ongoing and future research benefit. Copyright © 2018 Elsevier Ltd. All rights reserved.
Follicular flushing during oocyte retrieval: a systematic review and meta-analysis.
Roque, Matheus; Sampaio, Marcos; Geber, Selmo
2012-11-01
The purpose of this systematic review and meta-analysis was to examine the literature and identify randomized controlled trials (RCTs), in order to answer if performing follicular flushing during the oocyte retrieval may improve the assisted reproductive technologies (ART) outcomes. An exhaustive electronic search was performed using MEDLINE and EMBASE databases. Only RCTs comparing follicular flushing to aspiration only during ART, were included. We included 5 trials, with a total of 482 patients randomized, with median ages ranging from 30.5 to 37.1. The data analyses did not show significant differences regarding live birth rate, clinical pregnancies rates, and the number of oocytes retrieved. The duration of oocyte retrieval was significantly increased in the follicular flushing group. The results from this systematic review and meta-analysis suggest that there is no advantage to use of routine follicular flushing during OR in an unselected group of patients.
The compound 2', 7'-dichlorodihydrofluoroscein diacetate is a probe commonly used to detect oxidative activity in live cells. Studies were undertaken to measure reactive oxygen species generated in freshly isolated rainbow trout hepatocytes exposed to a variety of redox cycling c...
Merritt, M.L.
1993-01-01
The simulation of the transport of injected freshwater in a thin brackish aquifer, overlain and underlain by confining layers containing more saline water, is shown to be influenced by the choice of the finite-difference approximation method, the algorithm for representing vertical advective and dispersive fluxes, and the values assigned to parametric coefficients that specify the degree of vertical dispersion and molecular diffusion that occurs. Computed potable water recovery efficiencies will differ depending upon the choice of algorithm and approximation method, as will dispersion coefficients estimated based on the calibration of simulations to match measured data. A comparison of centered and backward finite-difference approximation methods shows that substantially different transition zones between injected and native waters are depicted by the different methods, and computed recovery efficiencies vary greatly. Standard and experimental algorithms and a variety of values for molecular diffusivity, transverse dispersivity, and vertical scaling factor were compared in simulations of freshwater storage in a thin brackish aquifer. Computed recovery efficiencies vary considerably, and appreciable differences are observed in the distribution of injected freshwater in the various cases tested. The results demonstrate both a qualitatively different description of transport using the experimental algorithms and the interrelated influences of molecular diffusion and transverse dispersion on simulated recovery efficiency. When simulating natural aquifer flow in cross-section, flushing of the aquifer occurred for all tested coefficient choices using both standard and experimental algorithms. ?? 1993.
NASA Astrophysics Data System (ADS)
Nashida, Norihiro; Suzuki, Hiroaki
A microfluidic system with injecting and flushing functions was developed. In the system, hydrophilic flow channels have a dry-film photoresist layer which facilitates the introduction of solutions from four injection ports. The injection and flushing of solutions are controlled by valves operated by electrowetting. The valves consist of gold working electrodes in the flow channels or a through-hole in the glass substrate. Solutions can be sequentially introduced through the injection ports into a reaction chamber and flushed through a valve in the through-hole. Necessary immunoassay steps can be conducted on the chip, and a target antibody can be detected electrochemically.
Wilkin, J K
1983-03-01
The effects of clonidine hydrochloride, an agent effective in suppressing other types of flushing reactions, were investigated in patients with erythematotelangiectatic rosacea. Clonidine hydrochloride, 0.05 mg, was given orally twice daily for two weeks. Mean arterial BP was not altered during clonidine treatment. Flushing reactions provoked with water at 60 degrees C, red wine, and chocolate were not suppressed during clonidine treatment. Clonidine did lead to malar hypothermia. It may be that any treatment benefit obtained from the reduction in vascular reactivity by clonidine in rosacea is offset by the malar hypothermia.
Fu, Yongshuo S. H.; Campioli, Matteo; Vitasse, Yann; De Boeck, Hans J.; Van den Berge, Joke; AbdElgawad, Hamada; Asard, Han; Piao, Shilong; Deckmyn, Gaby; Janssens, Ivan A.
2014-01-01
Recent temperature increases have elicited strong phenological shifts in temperate tree species, with subsequent effects on photosynthesis. Here, we assess the impact of advanced leaf flushing in a winter warming experiment on the current year’s senescence and next year’s leaf flushing dates in two common tree species: Quercus robur L. and Fagus sylvatica L. Results suggest that earlier leaf flushing translated into earlier senescence, thereby partially offsetting the lengthening of the growing season. Moreover, saplings that were warmed in winter–spring 2009–2010 still exhibited earlier leaf flushing in 2011, even though the saplings had been exposed to similar ambient conditions for almost 1 y. Interestingly, for both species similar trends were found in mature trees using a long-term series of phenological records gathered from various locations in Europe. We hypothesize that this long-term legacy effect is related to an advancement of the endormancy phase (chilling phase) in response to the earlier autumnal senescence. Given the importance of phenology in plant and ecosystem functioning, and the prediction of more frequent extremely warm winters, our observations and postulated underlying mechanisms should be tested in other species. PMID:24799708
Water Reclamation Using a Ceramic Nanofiltration Membrane and Surface Flushing with Ozonated Water
Hoang, Anh T.; Okuda, Tetsuji; Takeuchi, Haruka; Tanaka, Hiroaki; Nghiem, Long D.
2018-01-01
A new membrane fouling control technique using ozonated water flushing was evaluated for direct nanofiltration (NF) of secondary wastewater effluent using a ceramic NF membrane. Experiments were conducted at a permeate flux of 44 L/m2h to evaluate the ozonated water flushing technique for fouling mitigation. Surface flushing with clean water did not effectively remove foulants from the NF membrane. In contrast, surface flushing with ozonated water (4 mg/L dissolved ozone) could effectively remove most foulants to restore the membrane permeability. This surface flushing technique using ozonated water was able to limit the progression of fouling to 35% in transmembrane pressure increase over five filtration cycles. Results from this study also heighten the need for further development of ceramic NF membrane to ensure adequate removal of pharmaceuticals and personal care products (PPCPs) for water recycling applications. The ceramic NF membrane used in this study showed approximately 40% TOC rejection, and the rejection of PPCPs was generally low and highly variable. It is expected that the fouling mitigation technique developed here is even more important for ceramic NF membranes with smaller pore size and thus better PPCP rejection. PMID:29671797
Cigarette smoking, androgen levels, and hot flushes in midlife women.
Cochran, Chrissy J; Gallicchio, Lisa; Miller, Susan R; Zacur, Howard; Flaws, Jodi A
2008-11-01
To test the hypothesis that cigarette smoking is associated with hot flushes through a mechanism involving androgen levels, progesterone levels, sex hormone-binding globulin levels, or the ratio of androgens to estrogens. Women with and without hot flushes were recruited from Baltimore, Maryland, and the surrounding counties. Women were between 45 and 54 years of age, with at least three menstrual periods in the previous 12 months, and were not postmenopausal. Study participants completed a questionnaire and gave a blood sample for hormone measurements. Current smokers had significantly higher androstenedione levels and a higher androgen-to-estrogen ratio than never smokers. Current smokers had significantly lower progesterone levels compared with never smokers. Former and current cigarette smokers had increased odds of experiencing hot flushes compared with never smokers (former: odds ratio [OR] 1.41, 95% confidence interval [CI] 0.99-2.01; current: OR 2.43, 95% CI 1.28-4.62). This association, however, was not attenuated by the addition of hormones to the smoking and hot-flush model. Cigarette smoking is associated with hot flushes through a mechanism that may not involve alterations in hormone levels or their ratios. II.
Fu, Yongshuo S H; Campioli, Matteo; Vitasse, Yann; De Boeck, Hans J; Van den Berge, Joke; AbdElgawad, Hamada; Asard, Han; Piao, Shilong; Deckmyn, Gaby; Janssens, Ivan A
2014-05-20
Recent temperature increases have elicited strong phenological shifts in temperate tree species, with subsequent effects on photosynthesis. Here, we assess the impact of advanced leaf flushing in a winter warming experiment on the current year's senescence and next year's leaf flushing dates in two common tree species: Quercus robur L. and Fagus sylvatica L. Results suggest that earlier leaf flushing translated into earlier senescence, thereby partially offsetting the lengthening of the growing season. Moreover, saplings that were warmed in winter-spring 2009-2010 still exhibited earlier leaf flushing in 2011, even though the saplings had been exposed to similar ambient conditions for almost 1 y. Interestingly, for both species similar trends were found in mature trees using a long-term series of phenological records gathered from various locations in Europe. We hypothesize that this long-term legacy effect is related to an advancement of the endormancy phase (chilling phase) in response to the earlier autumnal senescence. Given the importance of phenology in plant and ecosystem functioning, and the prediction of more frequent extremely warm winters, our observations and postulated underlying mechanisms should be tested in other species.
Ambrus, R; Svendsen, L B; Secher, N H; Goetze, J P; Rünitz, K; Achiam, M P
2017-09-01
During abdominal surgery, traction of the mesenterium provokes mesenteric traction syndrome, including hypotension, tachycardia, and flushing, along with an increase in plasma prostacyclin (PGI 2 ). We evaluated whether postoperative complications are related to mesenteric traction syndrome during esophagectomy. Flushing, hemodynamic variables, and plasma 6-keto-PGF 1α were recorded during the abdominal part of open ( n = 25) and robotically assisted ( n = 25) esophagectomy. Postoperative complications were also registered, according to the Clavien-Dindo classification. Flushing appeared in 17 (open) and 5 (robotically assisted) surgical cases ( p = 0.001). Mean arterial pressure was stable during both types of surgeries, but infusion of vasopressors during the first hour of open surgery was related to development of widespread (Grade II) flushing ( p = 0.036). For patients who developed flushing, heart rate and plasma 6-keto-PGF 1α also increased ( p = 0.001 and p < 0.001, respectively). Furthermore, severe postoperative complications were related to Grade II flushing ( p = 0.037). Mesenteric traction syndrome manifests more frequently during open than robotically assisted esophagectomy, and postoperative complications appear to be associated with severe mesenteric traction syndrome.
Water Reclamation Using a Ceramic Nanofiltration Membrane and Surface Flushing with Ozonated Water.
Fujioka, Takahiro; Hoang, Anh T; Okuda, Tetsuji; Takeuchi, Haruka; Tanaka, Hiroaki; Nghiem, Long D
2018-04-19
A new membrane fouling control technique using ozonated water flushing was evaluated for direct nanofiltration (NF) of secondary wastewater effluent using a ceramic NF membrane. Experiments were conducted at a permeate flux of 44 L/m²h to evaluate the ozonated water flushing technique for fouling mitigation. Surface flushing with clean water did not effectively remove foulants from the NF membrane. In contrast, surface flushing with ozonated water (4 mg/L dissolved ozone) could effectively remove most foulants to restore the membrane permeability. This surface flushing technique using ozonated water was able to limit the progression of fouling to 35% in transmembrane pressure increase over five filtration cycles. Results from this study also heighten the need for further development of ceramic NF membrane to ensure adequate removal of pharmaceuticals and personal care products (PPCPs) for water recycling applications. The ceramic NF membrane used in this study showed approximately 40% TOC rejection, and the rejection of PPCPs was generally low and highly variable. It is expected that the fouling mitigation technique developed here is even more important for ceramic NF membranes with smaller pore size and thus better PPCP rejection.
Munsch-Alatossava, Patricia; Alatossava, Tapani
2014-01-01
Gram-negative Pseudomonas and Gram-positive Bacillus are the most common spoilage bacteria in raw and pasteurized milk, respectively. In previous studies, nitrogen (N2) gas flushing treatments of raw and pasteurized milk at cold chain-temperatures inhibited bacterial spoilage and highlighted different susceptibilities to the N2 treatment with the exclusion of certain bacterial types. Here, we investigated the effects of pure N2 gas flushing on representative strains of these genera grown in mono- or co-cultures at 15 and 25°C. Bacillus weihenstephanensis, a frequent inhabitant of fluid dairy products, is represented by the genome-sequenced KBAB4 strain. Among Pseudomonas, P. tolaasii LMG 2342(T) and strain C1, a raw milk psychrotroph, were selected. The N2 gas flushing treatment revealed: (1) temperature-dependent responses; (2) inhibition of the growth of both pseudomonads; (3) emergence of small colony variants (SCVs) for B. weihenstephanensis strain KBAB4 at 15°C induced by the N2 treatment or when grown in co-culture with Pseudomonas strains; (4) N2 gas flushing modulates (suppressed or stimulated) bacterial antagonistic reactions in co-cultures; (5) most importantly, scanning electron microscopy (SEM) and transmission electron microscopy (TEM) analyses revealed that at 25°C the majority of the KBAB4 cells were killed by pure N2 gas flushing. This observation constitutes the first evidence that N2 gas flushing has bactericidal effects.
Hinds, Angelique C; Baskin, Laurence S
2004-10-01
The Malone antegrade continence enema procedure has changed the lives of many school-aged children who would otherwise be in diapers. Unfortunately, our current procedures to flush the Malone antegrade continence enema are difficult to accomplish independently and require an extensive time commitment. In this study we confirm that a new device, the ACE Malone automatic instillation device (ACE-MAID) is safe and effective, will decrease the time it takes to perform the flush and will increase independence. Nine patients were prospectively enrolled for a 1-year study. Patient age ranged from 4 to 16 years, and diagnoses included spina bifida (3 cases), imperforate anus (4) and infantile meningitis (1). The study consisted of initial and followup questionnaires, an "ACE-O-Gram," quality assurance testing of the ACE-MAID and an objective observation of current flushing technique. The average objective start to finish flush time decreased from 45 minutes initially to 31 minutes using the ACE-MAID. Children who initially had more than 1 accident per month had a decrease in the number of stool accidents. When asked to compare the ACE-MAID device to the previous form of flushing 100% of patients stated that it was better. When asked if they would use the pump when the study was over 100% reported yes. The new ACE-MAID proved safe and effective, decreased flush times, may decrease stool accidents and facilitates independence for children treated with a MACE procedure.
Rondeau, M; Guay, P; Goff, A K; Cooke, G M
1996-01-01
The aim of this study was to compare the development and metabolic activity of cultured murine and bovine embryos in 2 standard media (HAM F-10 and RPMI) in the presence or absence of bovine uterine flushings. Murine morulae (n = 653) and day 7 bovine embryos (n = 273) were cultured for 18 h or 36 h in either HAM F-10 or RPMI in the presence or absence of bovine uterine flushings. After culture, the development, quality, and metabolic activity (glucose utilization or methionine uptake and incorporation) of embryos was assessed. It was found that HAM F-10 (without uterine flushings) was a more suitable medium than RPMI for optimal development and metabolism of murine and bovine embryos. Poor quality and development, as well as decreased metabolism, were evident after culture of murine embryos in RPMI; in contrast, this medium had no adverse effects on bovine embryos in culture. Supplementation of HAM F-10 with bovine uterine flushings improved the growth of murine embryos and the protein synthesis (as measured by an increased methionine incorporation) for both murine and bovine embryos. However, supplementation with bovine uterine flushings could not overcome deficiencies of an inappropriate medium (RPMI) for murine embryos. Supplementation of a well-defined culture medium with uterine flushings increased metabolism of embryos in culture, and thus might help to increase pregnancy rates after transfer of such embryos to recipient cows. PMID:8825988
Real-Time Station Grouping under Dynamic Traffic for IEEE 802.11ah
Tian, Le; Latré, Steven
2017-01-01
IEEE 802.11ah, marketed as Wi-Fi HaLow, extends Wi-Fi to the sub-1 GHz spectrum. Through a number of physical layer (PHY) and media access control (MAC) optimizations, it aims to bring greatly increased range, energy-efficiency, and scalability. This makes 802.11ah the perfect candidate for providing connectivity to Internet of Things (IoT) devices. One of these new features, referred to as the Restricted Access Window (RAW), focuses on improving scalability in highly dense deployments. RAW divides stations into groups and reduces contention and collisions by only allowing channel access to one group at a time. However, the standard does not dictate how to determine the optimal RAW grouping parameters. The optimal parameters depend on the current network conditions, and it has been shown that incorrect configuration severely impacts throughput, latency and energy efficiency. In this paper, we propose a traffic-adaptive RAW optimization algorithm (TAROA) to adapt the RAW parameters in real time based on the current traffic conditions, optimized for sensor networks in which each sensor transmits packets with a certain (predictable) frequency and may change the transmission frequency over time. The TAROA algorithm is executed at each target beacon transmission time (TBTT), and it first estimates the packet transmission interval of each station only based on packet transmission information obtained by access point (AP) during the last beacon interval. Then, TAROA determines the RAW parameters and assigns stations to RAW slots based on this estimated transmission frequency. The simulation results show that, compared to enhanced distributed channel access/distributed coordination function (EDCA/DCF), the TAROA algorithm can highly improve the performance of IEEE 802.11ah dense networks in terms of throughput, especially when hidden nodes exist, although it does not always achieve better latency performance. This paper contributes with a practical approach to optimizing RAW grouping under dynamic traffic in real time, which is a major leap towards applying RAW mechanism in real-life IoT networks. PMID:28677617
Real-Time Station Grouping under Dynamic Traffic for IEEE 802.11ah.
Tian, Le; Khorov, Evgeny; Latré, Steven; Famaey, Jeroen
2017-07-04
IEEE 802.11ah, marketed as Wi-Fi HaLow, extends Wi-Fi to the sub-1 GHz spectrum. Through a number of physical layer (PHY) and media access control (MAC) optimizations, it aims to bring greatly increased range, energy-efficiency, and scalability. This makes 802.11ah the perfect candidate for providing connectivity to Internet of Things (IoT) devices. One of these new features, referred to as the Restricted Access Window (RAW), focuses on improving scalability in highly dense deployments. RAW divides stations into groups and reduces contention and collisions by only allowing channel access to one group at a time. However, the standard does not dictate how to determine the optimal RAW grouping parameters. The optimal parameters depend on the current network conditions, and it has been shown that incorrect configuration severely impacts throughput, latency and energy efficiency. In this paper, we propose a traffic-adaptive RAW optimization algorithm (TAROA) to adapt the RAW parameters in real time based on the current traffic conditions, optimized for sensor networks in which each sensor transmits packets with a certain (predictable) frequency and may change the transmission frequency over time. The TAROA algorithm is executed at each target beacon transmission time (TBTT), and it first estimates the packet transmission interval of each station only based on packet transmission information obtained by access point (AP) during the last beacon interval. Then, TAROA determines the RAW parameters and assigns stations to RAW slots based on this estimated transmission frequency. The simulation results show that, compared to enhanced distributed channel access/distributed coordination function (EDCA/DCF), the TAROA algorithm can highly improve the performance of IEEE 802.11ah dense networks in terms of throughput, especially when hidden nodes exist, although it does not always achieve better latency performance. This paper contributes with a practical approach to optimizing RAW grouping under dynamic traffic in real time, which is a major leap towards applying RAW mechanism in real-life IoT networks.
Rodney E. Will; Greg Barron-Gafford; Robert O. Teskey; Barry D. Shiver
2004-01-01
Mid-summer foliar nitrogen concentrations (N) were measured at three canopy positions (upper, middle, lower), two foliage ages per canopy position (current-year and 1-year-old), and two flushes per age class (first flush and second flush) in 4-year-old loblolly (Pinus taeda L.) and slash pine (Pinus elliottii Engelm.) stands...
K.D. Jermstad; D.L. Bassoni; K.S. Jech; N.C. Wheeler; D.B. Neale
2001-01-01
Abstract Thirty three unique quantitative trait loci (QTLs) affecting the timing of spring bud flush have been identified in an intraspecific mapping population of coastal Douglas-fir [Pseudotsuga menziesii (Mirb.) Franco var. menziesii]. Both terminal and lateral bud flush were measured over a 4-year period on clonal replicates at two test sites, allowing for the...
Richard E. Dickson; Patricia T. Tomlinson; J. G. Isebrands
2000-01-01
The episodic or flushing growth habit of northern red oak (Quercus rubra L.,) has a significant influence on carbon fixation, carbon transport from source leaves, and carbon allocation within the plant; however, the impact of episodic growth on carbon parciprioning among chemical fractions is unknown. Median-flush leaves of the first and second flush...
Huynh, Lynn; Totev, Todor; Vekeman, Francis; Neary, Maureen P; Duh, Mei S; Benson, Al B
2017-09-01
To calculate the cost reduction associated with diarrhea/flushing symptom resolution/improvement following treatment with above-standard dose octreotide-LAR from the commercial payor's perspective. Diarrhea and flushing are two major carcinoid syndrome symptoms of neuroendocrine tumor (NET). Previously, a study of NET patients from three US tertiary oncology centers (NET 3-Center Study) demonstrated that dose escalation of octreotide LAR to above-standard dose resolved/improved diarrhea/flushing in 79% of the patients within 1 year. Time course of diarrhea/flushing symptom data were collected from the NET 3-Center Study. Daily healthcare costs were calculated from a commercial claims database analysis. For the patient cohort experiencing any diarrhea/flushing symptom resolution/improvement, their observation period was divided into days of symptom resolution/improvement or no improvement, which were then multiplied by the respective daily healthcare cost and summed over 1 year to yield the blended mean annual cost per patient. For patients who experienced no diarrhea/flushing symptom improvement, mean annual daily healthcare cost of diarrhea/flushing over a 1-year period was calculated. The economic model found that 108 NET patients who experienced diarrhea/flushing symptom resolution/improvement within 1 year had statistically significantly lower mean annual healthcare cost/patient than patients with no symptom improvement, by $14,766 (p = .03). For the sub-set of 85 patients experiencing resolution/improvement of diarrhea, their cost reduction was more pronounced, at $18,740 (p = .01), statistically significantly lower than those with no improvement; outpatient costs accounted for 56% of the cost reduction (p = .02); inpatient costs, emergency department costs, and pharmacy costs accounted for the remaining 44%. The economic model relied on two different sources of data, with some heterogeneity in the prior treatment and disease status of patients. Symptom resolution/improvement of diarrhea/flushing after treatment with an above-standard dose of octreotide-LAR in NET was associated with a statistically significant healthcare cost decrease compared to a scenario of no symptom improvement.
Call, Anson C; St Clair, Samuel B
2017-09-01
In the spring of 2015, a severe outbreak of the necrotrophic pathogen Drepanopeziza (also known as Marssonina) spread across large portions of aspen (Populus tremuloides Michx.) forests in the western United States. Among adjacent stands, some were diseased and others were not. Drepanopeziza infection in diseased aspen stands stimulated compensatory growth of second-flush leaves at the top of the canopy. These patterns of infection provided an opportunity to characterize associations of pathogen infection and leaf functional traits. Eight pairs of adjacent healthy and diseased aspen stands were identified across a forest landscape in northern Utah. Average leaf surface area, specific leaf area (SLA), photosynthesis, starch concentration and defense chemistry expression (phenolic glycosides and condensed tannins) were measured on original, first-flush leaves in the lower portion of the tree canopy of healthy and diseased stands and compensatory, second-flush leaves produced in the canopy top of diseased stands. Only first-flush leaves of diseased stands showed high levels of Drepanopeziza infection. Leaf area of second-flush leaves of diseased stands was threefold larger than all other leaf types in healthy or diseased stands. Lower canopy leaves of healthy stands had the highest SLA. Photosynthesis was lowest in infected first-flush leaves, highest in second-flush leaves of diseased stands and intermediate in leaves of healthy stands. Foliar starch concentrations were lower in leaves of diseased stands than leaves from healthy stands. Condensed tannins were greater in second-flush leaves than first-flush leaves in both healthy and diseased stands. Phenolic glycoside concentrations were lowest in infected leaves of diseased stands. Diseased stands leafed out a week earlier in the spring than healthy stands, which may have exposed their emerging leaves to rainy conditions that promote Drepanopeziza infection. Compensatory leaf regrowth of diseased stands appears to offset some of the functional loss (i.e., photosynthetic capacity) of infected leaves. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Kim, Kun-Hyung; Kang, Kyung-Won; Jung, Hee-Jung; Park, Ji-Eun; Jung, So-Young; Choi, Jun-Yong; Choi, Sun-Mi
2008-01-01
Background Hot flushes are the most frequent climacteric symptom and a major cause of suffering among menopausal women. The condition negatively influences many aspects of women's lives. To date, conventional hormone replacement therapy (HRT) is considered the most effective treatment for hot flushes. However, HRT is associated with a host of negative side effects. Complementary and alternative medical (CAM) approaches have been employed to relieve symptoms and to avoid these side effects. Acupuncture is one of the most strongly preferred CAM treatments for many diseases, causing few serious adverse effects, and is frequently used in Korea. We aim to evaluate the effectiveness of Traditional Korean Acupuncture (TKA) in conjunction with usual care, compared to usual care alone, on hot flushes in perimenopausal and postmenopausal women in Korea. Methods This study consists of a multi-center randomized controlled trial with 2 parallel arms. Participants included in the study will meet the following criteria: 1) a documented daily average hot flush score ≥ 10 for one week prior to the screening visit 2) not taking HRT and other pharmaceutical therapies which might affect hot flushes or other vasomotor symptoms. While maintaining usual care, the treatment group will receive acupuncture 3 times a week, for a total of 12 sessions over 4 weeks. The control group will receive usual care alone during the same period. Post-treatment follow-up will be performed one month after completing 12 sessions of acupuncture. Discussion This trial will provide evidence for the effectiveness of acupuncture as a treatment for hot flushes. The primary endpoint in both groups is a change in hot flush score from baseline to week 4 and/or week 8. As the secondary endpoint, we will employ the Menopause Rating Scale (MRS), a health-related quality of life questionnaire. Further analysis will examine the frequency, severity and difference in symptoms for daytime vs. nighttime hot flushes, sub-domain analysis of MRS, and participants' expectations of acupuncture treatment. Trial registration Current Controlled Trials ISRCTN49335612 PMID:19055763
The application of improved flow diverter for first flush management.
Mrowiec, M
2010-01-01
The paper presents the investigations on first flush phenomenon based on the total suspended solids (TSS) concentration measurement during selected rainfalls at central part of Czestochowa (Poland) and also the hydrodynamic model of the catchment. The model allows to present the conception of first flush management using an improved flow diverter Septurn. Flow diverters used in the separate sewer systems create a hybrid system called "semi-separate" sewage system, which allows to treat the first flush volume in the waste water treatment plant (WWTP). Proposed construction of the flow diverter makes possible to capture significant part of the pollutant load (TSS) and simultaneously to reduce volume discharges to WWTPs during wet weather.
Leachate flush strategies for managing volatile fatty acids accumulation in leach-bed reactors.
Riggio, S; Torrijos, M; Vives, G; Esposito, G; van Hullebusch, E D; Steyer, J P; Escudié, R
2017-05-01
In anaerobic leach-bed reactors (LBRs) co-digesting an easily- and a slowly-degradable substrate, the importance of the leachate flush both on extracting volatile fatty acids (VFAs) at the beginning of newly-started batches and on their consumption in mature reactors was tested. Regarding VFA extraction three leachate flush-rate conditions were studied: 0.5, 1 and 2Lkg -1 TSd -1 . Results showed that increasing the leachate flush-rate during the acidification phase is essential to increase degradation kinetics. After this initial phase, leachate injection is less important and the flush-rate could be reduced. The injection in mature reactors of leachate with an acetic acid concentration of 5 or 10gL -1 showed that for an optimized VFA consumption in LBRs, VFAs should be provided straight after the methane production peak in order to profit from a higher methanogenic activity, and every 6-7h to maintain a high biogas production rate. Copyright © 2017 Elsevier Ltd. All rights reserved.
Rance, Naomi E.; Dacks, Penny A.; Mittelman-Smith, Melinda A.; Romanovsky, Andrej A.; Krajewski-Hall, Sally J.
2013-01-01
Despite affecting millions of individuals, the etiology of hot flushes remains unknown. Here we review the physiology of hot flushes, CNS pathways regulating heat-dissipation effectors, and effects of estrogen on thermoregulation in animal models. Based on the marked changes in hypothalamic kisspeptin, neurokinin B and dynorphin (KNDy) neurons in postmenopausal women, we hypothesize that KNDy neurons play a role in the mechanism of flushes. In the rat, KNDy neurons project to preoptic thermoregulatory areas that express the neurokinin 3 receptor (NK3R), the primary receptor for NKB. Furthermore, activation of NK3R in the median preoptic nucleus, part of the heat-defense pathway, reduces body temperature. Finally, ablation of KNDy neurons reduces cutaneous vasodilatation and partially blocks the effects of estrogen on thermoregulation. These data suggest that arcuate KNDy neurons relay estrogen signals to preoptic structures regulating heat-dissipation effectors, supporting the hypothesis that KNDy neurons participate in the generation of flushes. PMID:23872331
Simulated formation and flow of microemulsions during surfactant flushing of contaminated soil.
Ouyan, Ying; Cho, Jong Soo; Mansell, Robert S
2002-01-01
Contamination of groundwater resources by non-aqueous phase liquids (NAPLs) has become an issue of increasing environmental concern. This study investigated the formation and flow of microemulsions during surfactant flushing of NAPL-contaminated soil using the finite difference model UTCHEM, which was verified with our laboratory experimental data. Simulation results showed that surfactant flushing of NAPLs (i.e., trichloroethylene and tetrachloroethylene) from the contaminated soils was an emulsion-driven process. Formation of NAPL-in-water microemulsions facilitated the removal of NAPLs from contaminated soils. Changes in soil saturation pressure were used to monitor the mobilization and entrapment of NAPLs during surface flushing process. In general, more NAPLs were clogged in soil pores when the soil saturation pressure increased. Effects of aquifer salinity on the formation and flow of NAPL-in-water microemulsions were significant. This study suggests that the formation and flow of NAPL-in-water microemulsions through aquifer systems are complex physical-chemical phenomena that are critical to effective surfactant flushing of contaminated soils.
Wolfe, Kelly L; Liu, Rui Hai
2007-10-31
A cellular antioxidant activity (CAA) assay for quantifying the antioxidant activity of phytochemicals, food extracts, and dietary supplements has been developed. Dichlorofluorescin is a probe that is trapped within cells and is easily oxidized to fluorescent dichlorofluorescein (DCF). The method measures the ability of compounds to prevent the formation of DCF by 2,2'-azobis(2-amidinopropane) dihydrochloride (ABAP)-generated peroxyl radicals in human hepatocarcinoma HepG2 cells. The decrease in cellular fluorescence when compared to the control cells indicates the antioxidant capacity of the compounds. The antioxidant activities of selected phytochemicals and fruit extracts were evaluated using the CAA assay, and the results were expressed in micromoles of quercetin equivalents per 100 micromol of phytochemical or micromoles of quercetin equivalents per 100 g of fresh fruit. Quercetin had the highest CAA value, followed by kaempferol, epigallocatechin gallate (EGCG), myricetin, and luteolin among the pure compounds tested. Among the selected fruits tested, blueberry had the highest CAA value, followed by cranberry > apple = red grape > green grape. The CAA assay is a more biologically relevant method than the popular chemistry antioxidant activity assays because it accounts for some aspects of uptake, metabolism, and location of antioxidant compounds within cells.
Threat facilitates subsequent executive control during anxious mood.
Birk, Jeffrey L; Dennis, Tracy A; Shin, Lisa M; Urry, Heather L
2011-12-01
Dual competition framework (DCF) posits that low-level threat may facilitate behavioral performance by influencing executive control functions. Anxiety is thought to strengthen this effect by enhancing threat's affective significance. To test these ideas directly, we examined the effects of low-level threat and experimentally induced anxiety on one executive control function, the efficiency of response inhibition. In Study 1, briefly presented stimuli that were mildly threatening (i.e., fearful faces) relative to nonthreatening (i.e., neutral faces) led to facilitated executive control efficiency during experimentally induced anxiety. No such effect was observed during an equally arousing, experimentally induced happy mood state. In Study 2, we assessed the effects of low-level threat, experimentally induced anxiety, and individual differences in trait anxiety on executive control efficiency. Consistent with Study 1, fearful relative to neutral faces led to facilitated executive control efficiency during experimentally induced anxiety. No such effect was observed during an experimentally induced neutral mood state. Moreover, individual differences in trait anxiety did not moderate the effects of threat and anxiety on executive control efficiency. The findings are partially consistent with the predictions of DCF in that low-level threat improved executive control, at least during a state of anxiety. (c) 2011 APA, all rights reserved.
Tampo, Yoshiko; Kotamraju, Srigiridhar; Chitambar, Christopher R; Kalivendi, Shasi V; Keszler, Agnes; Joseph, Joy; Kalyanaraman, B
2003-01-10
Dichlorodihydrofluorescein (DCFH) is one of the most frequently used probes for detecting intracellular oxidative stress. In this study, we report that H2O2-dependent intracellular oxidation of DCFH to a green fluorescent product, 2',7'-dichlorofluorescein (DCF), required the uptake of extracellular iron transported through a transferrin receptor (TfR) in endothelial cells. H2O2-induced DCF fluorescence was inhibited by the monoclonal IgA-class anti-TfR antibody (42/6) that blocked TfR endocytosis and the iron uptake. H2O2-mediated inactivation of cytosolic aconitase was responsible for activation of iron regulatory protein-1 and increased expression of TfR, resulting in an increased iron uptake into endothelial cells. H2O2-mediated caspase-3 proteolytic activation was inhibited by anti-TfR antibody. Similar results were obtained in the presence of a lipid hydroperoxide. We conclude that hydroperoxide-induced DCFH oxidation and endothelial cell apoptosis required the uptake of extracellular iron by the TfR-dependent iron transport mechanism and that the peroxide-induced iron signaling, in general, has broader implications in oxidative vascular biology.
Kataoka, Kozo; Tsushima, Takahiro; Mizusawa, Junki; Hironaka, Shuichi; Tsubosa, Yasuhiro; Kii, Takayuki; Shibuya, Yuichi; Chin, Keisho; Katayama, Hiroshi; Kato, Ken; Fukuda, Haruhiko; Kitagawa, Yuko
2015-05-01
Chemotherapy with cisplatin plus fluorouracil is the current standard treatment for metastatic or recurrent esophageal cancer. We have developed a 2-weekly docetaxel combined with CF regimen and conducted a Phase I/II trial for metastatic or recurrent esophageal cancer (JCOG0807). Promising efficacy and safety were shown in JCOG0807, and we have commenced a Phase III trial in September 2014 to confirm the superiority of 2-weekly DCF to CF for patients with metastatic or recurrent esophageal cancer. A total of 240 patients will be accrued from 41 Japanese institutions over a period of 4 years. The primary end point is overall survival. The secondary end points are progression-free survival, response rate and proportion of adverse events. This trial has been registered in the UMIN Clinical Trials Registry as UMIN000015107 (http://www.umin.ac.jp/ctr/index.htm). © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
A literature review and meta-analysis of drug company-funded mental health websites.
Read, J; Cain, A
2013-12-01
The pharmaceutical industry exercises pervasive influence in the mental health field. The internet has become a primary source of mental health information for the public and practitioners. This study therefore compared mental health websites funded and not funded by drug companies. A systematic literature review of studies examining the role of drug companies in the funding of mental health websites was conducted, followed by a meta-analysis of studies comparing drug company-funded (DCF) sites with sites not funded by the industry. Mental health websites, in general, overemphasize biogenetic causal explanations and medication. Many mental health websites (42%) are either drug company owned (6%) or receive funding from drug companies (36%). A meta-analysis found that DCF sites are significantly more biased toward biogenetic causes (P < 0.01) and toward medication (P < 0.0001) than sites that are financially independent of the industry. Practitioners are encouraged to inform patients about the bias inherent in industry-sponsored websites and to recommend, instead, more balanced websites that present a range of evidence-based information about causes and treatments. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Fu, Ling; Hamzeh, Mahsa; Dodard, Sabine; Zhao, Yuan H; Sunahara, Geoffrey I
2015-05-01
This study investigated the possibility that titanium dioxide nanoparticles (nano-TiO2) toxicity in Pseudokirchneriella subcapitata involves reactive oxygen species (ROS) production, using the dichlorodihydrofluorescein (DCF) assay. Algae were exposed to nano-TiO2 under laboratory fluorescent lamps supplemented with UV irradiation for 3h, with or without a UV filter. Results showed that nano-TiO2 increased ROS production in UV-exposed cells, with or without a UV filter (LOEC values were 250 and 10mg/L, respectively). Sublethal effects of nano-TiO2 on UV pre-exposed algae were also examined. Toxicity studies indicated that exposure to nano-TiO2 agglomerates decreased algal growth following 3h pre-exposure to UV, with or without a UV filter (EC50s were 8.7 and 6.3mg/L, respectively). The present study suggests that the growth inhibitory effects of nano-TiO2 in algae occurred at concentrations lower than those that can elevate DCF fluorescence, and that ROS generation is not directly involved with the sublethal effects of nano-TiO2 in algae. Copyright © 2015 Elsevier B.V. All rights reserved.
2006-08-31
volumetric depletion efficiency ( VDE ) considers how much DNAPL is depleted from the system, relative to the total volume of solution flushed through the...aqueous phase contaminant. VDE is important to consider, as conditions that result in the fastest mass transfer, highest enhancement, or best MTE, may...volumes of flushing fluid, maximizing DNAPL depletion while minimizing flushing volume requirements may be desirable from a remediation standpoint. VDE
Relation of body mass and sex steroid hormone levels to hot flushes in a sample of mid-life women.
Schilling, C; Gallicchio, L; Miller, S R; Langenberg, P; Zacur, H; Flaws, J A
2007-02-01
Previous studies indicate that obesity is associated with a higher risk of experiencing hot flushes in mid-life women. The reasons for this association are unknown, although altered hormone levels have been associated with both hot flushes and obesity. Thus, this current study tested the hypothesis that obesity is associated with hot flushes in mid-life women through a mechanism involving levels of total and free androgen, free estrogen, progesterone, and sex hormone binding globulin (SHBG). Women aged 45-54 years were recruited from Baltimore and its surrounding counties. Each participant (n=628) was weighed, measured, completed a questionnaire, and provided a blood sample that was used to measure estradiol, estrone, testosterone, androstenedione, dehydroepiandrosterone sulfate, progesterone, and SHBG. Obese mid-life women (body mass index (BMI)>or=30.0 kg/m2) had significantly higher testosterone, and lower estradiol, estrone, progesterone, and SHBG levels than normal-weight mid-life women (BMI
Bach, P M; McCarthy, D T; Deletic, A
2010-01-01
The management of stormwater pollution has placed particular emphasis on the first flush phenomenon. However, definition and current methods of analyses of the phenomena contain serious limitations, the most important being their inability to capture a possible impact of the event size (total event volume) on the first flush. This paper presents the development of a novel approach in defining and assessing the first flush that should overcome these problems. The phenomenon is present in a catchment if the decrease in pollution concentration with the absolute cumulative volume of runoff from the catchment is statistically significant. Using data from seven diverse catchments around Melbourne, Australia, changes in pollutant concentrations for Total Suspended Solids (TSS) and Total Nitrogen (TN) were calculated over the absolute cumulative runoff and aggregated from a collection of different storm events. Due to the discrete nature of the water quality data, each concentration was calculated as a flow-weighted average at 2 mm runoff volume increments. The aggregated concentrations recorded in each increment (termed as a 'slice' of runoff) were statistically compared to each other across the absolute cumulative runoff volume. A first flush is then defined as the volume at which concentrations reach the 'background concentration' (i.e. the statistically significant minimum). Initial results clearly highlight first flush and background concentrations in all but one catchment supporting the validity of this new approach. Future work will need to address factors, which will help assess the first flush's magnitude and volume. Sensitivity testing and correlation with catchment characteristics should also be undertaken.
Wilson, Louise F; Pandeya, Nirmala; Byles, Julie; Mishra, Gita D
2016-09-01
There is limited research on hot flushes and night sweats in women with a hysterectomy with ovarian conservation. We aimed to describe the patterns of these symptoms in a cohort of Australian women and to investigate the relationship between distinct symptom patterns and hysterectomy status. Repeated-measures latent class analysis (LCA) was used to identify hot flushes and night sweats symptom patterns across seven surveys (over 17 years) in the mid-cohort of the Australian Longitudinal Study on Women's Health. Multinomial logistic regression was used to assess the associations of the symptom patterns in women with a hysterectomy with ovarian conservation (n=1129) versus women without a hysterectomy (n=4977). A higher proportion of women with a hysterectomy than of those without experienced a constant pattern of hot flushes (15% versus 30%) and night sweats (9% versus 19%). Women with a hysterectomy had higher odds of constant hot flushes versus minimal hot flushes (OR=1.97, 95% CI: 1.64, 2.35) and constant versus minimal night sweats (OR=2.09, 95% CI: 1.70, 2.55). Smoking, a 'lower level of education to non-professional occupation' pathway and body mass index (BMI) patterns of 'always obese' and 'increasingly obese' were also associated with a higher risk of constant symptoms. Women who have a hysterectomy (with ovarian conservation) have a higher risk of hot flushes and night sweats that persist over an extended period. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Adams, A.; Gore, J.; Musser, F.; Cook, D.; Catchot, A.; Walker, T.; Awuni, G. A.
2015-01-01
Two experiments were conducted at the Delta Research and Extension Center in Stoneville, MS, during 2011 and 2012 to determine the impact of water management practices on the efficacy of insecticidal seed treatments targeting rice water weevil, Lissorhoptrus oryzophilus Kuschel. Larval densities and yield were compared for plots treated with labeled rates of thiamethoxam, chlorantraniliprole, and clothianidin and an untreated control. In the first experiment, plots were subjected to flood initiated at 6 and 8 wk after planting. Seed treatments significantly reduced larval densities with the 8-wk flood timing, but not the 6-wk flood timing. Overall, the treated plots yielded higher than the control plots. In the second experiment, the impact of multiple flushes on the efficacy of insecticidal seed treatments was evaluated. Plots were subjected to zero, one, or two flushes with water. All seed treatments reduced larval densities compared with the untreated control. Significantly fewer larvae were observed in plots that received one or two flushes compared with plots that did not receive a flush. All seed treatments resulted in higher yields compared to the untreated control in the zero and one flush treatments. When two flushes were applied, yield from the thiamethoxam and clothianidin treated plots was not significantly different from those of the control plots, while the chlorantraniliprole treated plots yielded significantly higher than the control. These data suggest that time from planting to flood did not impact the efficacy of seed treatments, but multiple flushes reduced the efficacy of thiamethoxam and clothianidin. PMID:26470232
Modulation of magmatic processes by CO2 flushing
NASA Astrophysics Data System (ADS)
Caricchi, Luca; Sheldrake, Tom E.; Blundy, Jon
2018-06-01
Magmatic systems are the engines driving volcanic eruptions and the source of fluids responsible for the formation of porphyry-type ore deposits. Sudden variations of pressure, temperature and volume in magmatic systems can produce unrest, which may culminate in a volcanic eruption and/or the abrupt release of ore-forming fluids. Such variations of the conditions within magmatic systems are commonly ascribed to the injection of new magma from depth. However, as magmas fractionating at depth or rising to the upper crust release CO2-rich fluids, the interaction between carbonic fluids and H2O-rich magmas stored in the upper crust (CO2 flushing), must also be a common process affecting the evolution of subvolcanic magma reservoirs. Here, we investigate the effect of gas injection on the stability and chemical evolution of magmatic systems. We calculate the chemical and physical evolution of magmas subjected to CO2-flushing using rhyolite-MELTS. We compare the calculations with a set of melt inclusion data for Mt. St. Helens, Merapi, Etna, and Stromboli volcanoes. We provide an approach that can be used to distinguish between melt inclusions trapped during CO2 flushing, magma ascent and decompression, or those affected by post-entrapment H2O-loss. Our results show that CO2 flushing is a widespread process in both felsic and mafic magmatic systems. Depending upon initial magma crystallinity and duration of CO2 input, flushing can either lead to volcanic eruption or fluid release. We suggest that CO2 flushing is a fundamental process modulating the behaviour and chemical evolution of crustal magmatic systems.
Pinkerton, JoAnn V; Bushmakin, Andrew G; Abraham, Lucy; Komm, Barry S; Bobula, Joel
2017-09-01
This post hoc analysis estimates time to transient and stable reductions in hot flush frequency in postmenopausal women using conjugated estrogens/bazedoxifene. In the 12-week Selective estrogens, Menopause, And Response to Therapy (SMART)-2 trial of conjugated estrogens/bazedoxifene 0.45 mg/20 mg and 0.625 mg/20 mg, women with at least seven moderate/severe hot flushes per day or 50 per week at screening recorded frequency of moderate/severe hot flushes in diaries. Nonparametric models and SAS Proc Lifetest were used to estimate median times to various degrees of transient reductions (first day with improvement) and stable reductions (first day with improvement maintained through study's end) in hot flush frequency. Treatment produced transient hot flush reductions of 40% to 100% and stable reductions of 30% to 100% significantly faster than placebo. Median time to a transient 50% reduction was 8 days for conjugated estrogens/bazedoxifene 0.45 mg/20 mg, 9.5 for 0.625 mg/20 mg, and 10 for placebo; median time to a stable 50% reduction was 9, 10, and 38 days. Median time to a transient 90% reduction was 32 and 22.5 days for 0.45 mg/20 mg and 0.625 mg/20 mg, and median time to a stable 90% reduction was 83 and 29 days, respectively; median times to transient/stable 90% reductions were not reached during the 12-week study in the placebo group. Although not all women using conjugated estrogens/bazedoxifene achieve permanent elimination of hot flushes, the frequency is likely to be substantially reduced during the first week to month. Women can expect approximately 50% reduction in hot flush frequency after about 8 to 10 days, and sustained improvement with continued treatment.
Development and growth of fruit bodies and crops of the button mushroom, Agaricus bisporus.
Straatsma, Gerben; Sonnenberg, Anton S M; van Griensven, Leo J L D
2013-10-01
We studied the appearance of fruit body primordia, the growth of individual fruit bodies and the development of the consecutive flushes of the crop. Relative growth, measured as cap expansion, was not constant. It started extremely rapidly, and slowed down to an exponential rate with diameter doubling of 1.7 d until fruit bodies showed maturation by veil breaking. Initially many outgrowing primordia were arrested, indicating nutritional competition. After reaching 10 mm diameter, no growth arrest occurred; all growing individuals, whether relatively large or small, showed an exponential increase of both cap diameter and biomass, until veil breaking. Biomass doubled in 0.8 d. Exponential growth indicates the absence of competition. Apparently there exist differential nutritional requirements for early growth and for later, continuing growth. Flushing was studied applying different picking sizes. An ordinary flushing pattern occurred at an immature picking size of 8 mm diameter (picking mushrooms once a day with a diameter above 8 mm). The smallest picking size yielded the highest number of mushrooms picked, confirming the competition and arrested growth of outgrowing primordia: competition seems less if outgrowing primordia are removed early. The flush duration (i.e. between the first and last picking moments) was not affected by picking size. At small picking size, the subsequent flushes were not fully separated in time but overlapped. Within 2 d after picking the first individuals of the first flush, primordia for the second flush started outgrowth. Our work supports the view that the acquisition of nutrients by the mycelium is demand rather than supply driven. For formation and early outgrowth of primordia, indications were found for an alternation of local and global control, at least in the casing layer. All these data combined, we postulate that flushing is the consequence of the depletion of some unknown specific nutrition required by outgrowing primordia. Copyright © 2013 The British Mycological Society. Published by Elsevier Ltd. All rights reserved.
Hypothesis of demodicidosis rosacea flushing etiopathogenesis.
Robledo, Mary Ann; Orduz, Mariana
2015-04-01
Most of the patients with erythematotelangiectatic rosacea are characterized by flushing, oedema and telangiectasia. The etiopathogenesis of the flushing in rosacea patients is unknown. Clinically the flushing in rosacea is similar to the "Asian flushing syndrome". Most Asians have an overactive alcohol dehydrogenase (ADH) that tends to break down alcohol into acetaldehyde faster. People with "Asians flushing syndrome" have a genetic disorder with the Aldehyde Dehydrogenase 2(∗)2 (ALDH2(∗)2) allele. This is the reason why they do not metabolize very well the acetaldehyde that comes from the alcohol, which means that acetaldehyde takes much longer to clear from their blood. ALDH2 enzyme is primarily responsible for oxidation of acetaldehyde derived from ethanol metabolism, as well as oxidation of various other endogenous and exogenous aldehydes. Acetaldehyde produces the vasodilatation in the "Asian flushing syndrome". The antibodies against the GroEl chaperonin protein, a 62-kDa heat shock protein were found in the Bacillus oleronius isolated from Demodex mites, in rosacea patients. The GroEl chaperonin protein is a protein that plays a key role in normal folding of ALDH2. If the GroEl chaperonin antibodies found in patients with rosacea, cross react with the human GroEl chaperonin protein, they will not fold normally the ALDH2, and then the enzyme will not metabolize the acetaldehyde. Many of the patients with rosacea have a concomitant infection with Helicobacter pylori in their stomach. The H.pylori produces high amounts of acetaldehyde, which comes from their metabolism of ethanol or carbohydrates. As a result, high amounts of acetaldehyde will circulate for longer time in the blood, until the liver CYP2E1(p450) enzyme system finally metabilizes the acetaldehyde, during that period of time the patients will experience a flushing as well as the people with the "Asian flushing syndrome" suffer when they drink ethanol. To prove the hypothesis it is necessary to find the cross reaction between the GroEl chaperonin antibodies against the B.oleronius and human GroEl chaperonin. Four groups of patients will be studied with or without the GroEl chaperonin antibodies, and H.Pylori. The production of acetaldehyde will be tested by the ethanol-derived microbial production method. If the hypothesis proves to be true, the treatment of Demodex mites and the H. pylori could improve the flushing in the rosacea patients and it will prevent the angiogenesis (telangiectasia), and the association of the gastric injury and carcinogenesis in those patients. Copyright © 2015 Elsevier Ltd. All rights reserved.
Flush Mounting Of Thin-Film Sensors
NASA Technical Reports Server (NTRS)
Moore, Thomas C., Sr.
1992-01-01
Technique developed for mounting thin-film sensors flush with surfaces like aerodynamic surfaces of aircraft, which often have compound curvatures. Sensor mounted in recess by use of vacuum pad and materials selected for specific application. Technique involves use of materials tailored to thermal properties of substrate in which sensor mounted. Together with customized materials, enables flush mounting of thin-film sensors in most situations in which recesses for sensors provided. Useful in both aircraft and automotive industries.
NASA Astrophysics Data System (ADS)
de Moura, Yhasmin Mendes; Galvão, Lênio Soares; Hilker, Thomas; Wu, Jin; Saleska, Scott; do Amaral, Cibele Hummel; Nelson, Bruce Walker; Lopes, Aline Pontes; Wiedeman, Kenia K.; Prohaska, Neill; de Oliveira, Raimundo Cosme; Machado, Carolyne Bueno; Aragão, Luiz E. O. C.
2017-09-01
The association between spectral reflectance and canopy processes remains challenging for quantifying large-scale canopy phenological cycles in tropical forests. In this study, we used a tower-mounted hyperspectral camera in an eastern Amazon forest to assess how canopy spectral signals of three species are linked with phenological processes in the 2012 dry season. We explored different approaches to disentangle the spectral components of canopy phenology processes and analyze their variations over time using 17 images acquired by the camera. The methods included linear spectral mixture analysis (SMA); principal component analysis (PCA); continuum removal (CR); and first-order derivative analysis. In addition, three vegetation indices potentially sensitive to leaf flushing, leaf loss and leaf area index (LAI) were calculated: the Enhanced Vegetation Index (EVI), Normalized Difference Vegetation Index (NDVI) and the entitled Green-Red Normalized Difference (GRND) index. We inspected also the consistency of the camera observations using Moderate Resolution Imaging Spectroradiometer (MODIS) and available phenological data on new leaf production and LAI of young, mature and old leaves simulated by a leaf demography-ontogeny model. The results showed a diversity of phenological responses during the 2012 dry season with related changes in canopy structure and greenness values. Because of the differences in timing and intensity of leaf flushing and leaf shedding, Erisma uncinatum, Manilkara huberi and Chamaecrista xinguensis presented different green vegetation (GV) and non-photosynthetic vegetation (NPV) SMA fractions; distinct PCA scores; changes in depth, width and area of the 681-nm chlorophyll absorption band; and variations over time in the EVI, GRND and NDVI. At the end of dry season, GV increased for Erisma uncinatum, while NPV increased for Chamaecrista xinguensis. For Manilkara huberi, the NPV first increased in the beginning of August and then decreased toward September with new foliage. Variations in red-edge position were not statistically significant between the species and across dates at the 95% confidence level. The camera data were affected by view-illumination effects, which reduced the SMA shade fraction over time. When MODIS data were corrected for these effects using the Multi-Angle Implementation of Atmospheric Correction Algorithm (MAIAC), we observed an EVI increase toward September that closely tracked the modeled LAI of mature leaves (3-5 months). Compared to the EVI, the GRND was a better indicator of leaf flushing because the modeled production of new leaves peaked in August and then declined in September following the GRND closely. While the EVI was more related to changes in mature leaf area, the GRND was more associated with new leaf flushing.
Jacobson, Terry A.
2010-01-01
Niacin is the most effective lipid-modifying agent for raising high-density lipoprotein cholesterol levels, but it also causes cutaneous vasodilation with flushing. To determine the frequency of flushing in clinical trials, as well as to delineate counseling and treatment approaches to prevent or manage flushing, a MEDLINE search was conducted of English-language literature from January 1, 1985, through April 7, 2009. This search used the title keywords niacin or nicotinic acid crossed with the Medical Subject Headings adverse effects and human. Niacin flushing is a receptor-mediated, mainly prostaglandin D2–driven phenomenon, the frequency, onset, and duration of which are largely determined by the distinct pharmacological and metabolic profiles of different niacin formulations. Subjective assessments include ratings of redness, warmth, itching, and tingling. In clinical trials, most (>60%) niacin users experienced mild or moderate flushing, which tended to decrease in frequency and severity with continued niacin treatment, even with advancing doses. Approximately 5% to 20% of patients discontinued treatment because of flushing. Flushing may be minimized by taking niacin with meals (or at bedtime with a low-fat snack), avoiding exacerbating factors (alcohol or hot beverages), and taking 325 mg of aspirin 30 minutes before niacin dosing. The current review advocates an initially slow niacin dose escalation from 0.5 to 1.0 g/d during 8 weeks and then from 1.0 to 2.0 g in a single titration step (if tolerated). Through effective counseling, treatment prophylaxis with aspirin, and careful dose escalation, adherence to niacin treatment can be improved significantly. Wider implementation of these measures should enable higher proportions of patients to reach sufficient niacin doses over time to prevent cardiovascular events. PMID:20360295
Bailey, Tom G; Cable, N Timothy; Aziz, Nabil; Dobson, Rebecca; Sprung, Victoria S; Low, David A; Jones, Helen
2016-07-01
Postmenopausal hot flushes occur due to a reduction in estrogen production causing thermoregulatory and vascular dysfunction. Exercise training enhances thermoregulatory control of sweating, skin and brain blood flow. We aimed to determine if improving thermoregulatory control and vascular function with exercise training alleviated hot flushes. Twenty-one symptomatic women completed a 7-day hot flush questionnaire and underwent brachial artery flow-mediated dilation and a cardiorespiratory fitness test. Sweat rate and skin blood flow temperature thresholds and sensitivities, and middle cerebral artery velocity (MCAv) were measured during passive heating. Women performed 16 weeks of supervised exercise training or control, and measurements were repeated. There was a greater improvement in cardiorespiratory fitness (4.45 mL/kg/min [95% CI: 1.87, 8.16]; P = 0.04) and reduced hot flush frequency (48 hot flushes/wk [39, 56]; P < 0.001) after exercise compared with control. Exercise reduced basal core temperature (0.14°C [0.01, 0.27]; P = 0.03) and increased basal MCAv (2.8 cm/s [1.0, 5.2]; P = 0.04) compared with control. Sweat rate and skin blood flow thresholds occurred approximately 0.19°C and 0.17°C earlier, alongside improved sweating sensitivity with exercise. MCAv decreased during heating (P < 0.005), but was maintained 4.5 cm/s (3.6, 5.5; P < 0.005) higher during heating after exercise compared with control (0.6 cm/s [-0.4, 1.4]). Exercise training that improves cardiorespiratory fitness reduces self-reported hot flushes. Improvements are likely mediated through greater thermoregulatory control in response to increases in core temperature and enhanced vascular function in the cutaneous and cerebral circulations.
Luo, Xia; Jellison, Kristen L; Huynh, Kevin; Widmer, Giovanni
2015-01-01
Multiple rotating annular reactors were seeded with biofilms flushed from water distribution systems to assess (1) whether biofilms grown in bioreactors are representative of biofilms flushed from the water distribution system in terms of bacterial composition and diversity, and (2) whether the biofilm sampling method affects the population profile of the attached bacterial community. Biofilms were grown in bioreactors until thickness stabilized (9 to 11 weeks) and harvested from reactor coupons by sonication, stomaching, bead-beating, and manual scraping. High-throughput sequencing of 16S rRNA amplicons was used to profile bacterial populations from flushed biofilms seeded into bioreactors as well as biofilms recovered from bioreactor coupons by different methods. β diversity between flushed and reactor biofilms was compared to β diversity between (i) biofilms harvested from different reactors and (ii) biofilms harvested by different methods from the same reactor. These analyses showed that average diversity between flushed and bioreactor biofilms was double the diversity between biofilms from different reactors operated in parallel. The diversity between bioreactors was larger than the diversity associated with different biofilm recovery methods. Compared to other experimental variables, the method used to recover biofilms had a negligible impact on the outcome of water biofilm analyses based on 16S amplicon sequencing. Results from this study show that biofilms grown in reactors over 9 to 11 weeks are not representative models of the microbial populations flushed from a distribution system. Furthermore, the bacterial population profile of biofilms grown in replicate reactors from the same flushed water are likely to diverge. However, four common sampling protocols, which differ with respect to disruption of bacterial cells, provide similar information with respect to the 16S rRNA population profile of the biofilm community.
FLUSH - PREDICTION OF FLOW PARAMETERS OF SLUSH HYDROGEN
NASA Technical Reports Server (NTRS)
Hardy, T.
1994-01-01
Slush hydrogen, a mixture of the solid and liquid phases of hydrogen, is a possible source of fuel for the National Aerospace Plane (NASP) Project. Advantages of slush hydrogen over liquid hydrogen include greater heat capacity and greater density. However, practical use of slush hydrogen as a fuel requires systems of lines, valves, etc. which are designed to deliver the fuel in slush form with minimal solid loss as a result of pipe heating or flow friction. Engineers involved with the NASP Project developed FLUSH to calculate the pressure drop and slush hydrogen solid fraction loss for steady-state, one-dimensional flow. FLUSH solves the steady-state, one-dimensional energy equation and the Bernoulli equation for pipe flow. The program performs these calculations for each two-node element--straight pipe length, elbow, valve, fitting, or other part of the piping system--specified by the user. The user provides flow rate, upstream pressure, initial solid hydrogen fraction, element heat leak, and element parameters such as length and diameter. For each element, FLUSH first calculates the pressure drop, then figures the slush solid fraction exiting the element. The code employs GASPLUS routines to calculate thermodynamic properties for the slush hydrogen. FLUSH is written in FORTRAN IV for DEC VAX series computers running VMS. An executable is provided on the tape. The GASPLUS physical properties routines which are required for building the executable are included as one object library on the program media (full source code for GASPLUS is available separately as COSMIC Program Number LEW-15091). FLUSH is available in DEC VAX BACKUP format on a 9-track 1600 BPI magnetic tape (standard media) or on a TK50 tape cartridge. FLUSH was developed in 1989.
Contamination removal by CO2 jet spray
NASA Astrophysics Data System (ADS)
Peterson, Ronald V.; Bowers, Charles W.
1990-11-01
Studies on the effectiveness of the jet flush in removing particle fallout and Arizona-standard fine dust on polished optical substrates have been carried out at ambient pressure and vacuum. These studies have shown that the CO2 jet flush is a viable method for removing contaminants from optical surfaces with no damage to the surface. The studies also show that the jet flush has potential for use as an on-orbit cleaning device for space optics.
Water Efficient Installations - A New Army Guidance Document
2010-06-01
Toilets 1.28 gpf or less, 50 manuf., 500+ models Required in CA Dual flush options also available WaterSense program provides certification and...lose 8760 to 219,000 gal/year Broken flush valve on toilet can lose 40 gal/hour US Army Corps of Engineers® Engineer Research and Development Center...Engineer Research and Development Center Toilets and Urinals ULFTs Ultra-Low Flush Toilet , also called low flow 1.28 gpf to 1.6 gpf HETs High Efficiency
Effect of aerobic training on hot flushes and quality of life—a randomized controlled trial
Luoto, Riitta; Moilanen, Jaana; Heinonen, Reetta; Mikkola, Tomi; Raitanen, Jani; Tomas, Eija; Ojala, Katriina; Mansikkamäai, Kirsi; Nygård, Clas-Håkan
2012-01-01
Background and objective. To estimate whether aerobic training has an effect on frequency of hot flushes or quality of life. Design. A randomized controlled trial. Participants and setting. Symptomatic, sedentary women (n = 176), 43–63 years, no current use of hormone therapy. Intervention. Unsupervised aerobic training for 50 minutes four times per week during 6 months. Outcomes. Hot flushes as measured with Women's Health Questionnaire (WHQ) and Health-Related Quality of Life (HRQoL, SF-36), daily reported hot flushes on phone-based diary, cardiorespiratory fitness (CRF), and body composition. Results. Intervention group had larger decrease in the frequency of night-time hot flushes based on phone diary (P for month X group = 0.012), but not on WHQ scale. Intervention group had less depressed mood (P= 0.01) than control women according to change in WHQ score. Changes in WHQ score in depressed mood (P = 0.03) and menstrual symptoms (P=0.01) in the intervention group were significantly dependent on frequency of training sessions. HRQoL was improved among the intervention group women in physical functioning (P= 0.049) and physical role limitation (P= 0.017). CRF improved (P= 0.008), and lean muscle mass increased (P= 0.046) significantly in the intervention group as compared to controls. Conclusions. Aerobic training may decrease the frequency of hot flushes and improve quality of life among slightly overweight women. PMID:21639722
NASA Astrophysics Data System (ADS)
Sung, Menghau; Teng, Chun-Hao; Yang, Tsung-Hsien
2017-07-01
Soil flushing using micro-nano-sized bubbles (MNB) in water as the flushing solution was tested in laboratory sand columns for the cleanup of residual trichloroethene (TCE) non-aqueous-phase-liquid (NAPL). Experiments considering flushing with MNB as well as ozone MNB (OZMNB) in water to treat soils contaminated with residual TCE liquid were conducted to examine effects of ozone on dissolution enhancement. The degrees of residual TCE saturation in soils, ranging from 0.44% to 7.6%, were tested. During flushings, aqueous TCE concentrations at the column exit were monitored and TCE masses remained in the columns after flushing were determined. Experimental results between runs with MNB and OZMNB in water revealed that dissolution enhancement was dependent on residual saturation conditions, and the maximum enhancement was around 9%. Governing equations consisting of three coupled partial differential equations (PDEs) were developed to model the system, and high-order finite difference (HOFD) method was employed to solve these PDEs. From mathematical modeling of reactive mass transfer under low residual saturation conditions (0.44% and 1.9%), experimental data were simulated and important controlling mechanisms were identified. It was concluded that a specific parameter pertinent to NAPL-water interfacial area in the Sherwood number had to be modified to satisfactorily describe the dissolution of TCE in the presence of MNB in water.
YoungStar in Milwaukee County: An Initial Progress Report as of July 2011
ERIC Educational Resources Information Center
Edie, Dave
2011-01-01
YoungStar is a program of the Department of Children and Families (DCF) created to improve the quality of child care for Wisconsin children. YoungStar is designed to: (1) Evaluate and rate the quality of care given by child care providers; (2) Help parents choose the best child care for their kids; (3) Support providers with tools and training to…
YoungStar in Wisconsin: An Initial Progress Report as of July 2011
ERIC Educational Resources Information Center
Edie, Dave
2011-01-01
YoungStar is a program of the Department of Children and Families (DCF) created to improve the quality of child care for Wisconsin children. YoungStar is designed to: (1) Evaluate and rate the quality of care given by child care providers; (2) Help parents choose the best child care for their kids; (3) Support providers with tools and training to…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Maienschein, J.L.; Garcia, F.; Garza, R.G.
Tritium-handling apparatus has been decontaminated as part of the shutdown of the LLNL Tritium Facility. Two stainless-steel gloveboxes that had been used to process lithium deuteride-tritide (LiDT) salt were decontaminated using the Portable Cleanup System so that they could be flushed with room air through the facility ventilation system. Further surface decontamination was performed by scrubbing the interior with paper towels and ethyl alcohol or Swish{trademark}. The surface contamination, as shown by swipe surveys, was reduced from 4{times}10{sup 4}--10{sup 6} disintegrations per minute (dpm)/cm{sup 2} to 2{times}10{sup 2}--4{times}10{sup 4} dpm/cm{sup 2}. Details on the decontamination operation are provided. A seriesmore » of metal (palladium and vanadium) hydride storage beds have been drained of tritium and flushed with deuterium in order to remove as much tritium as possible. The bed draining and flushing procedure is described, and a calculational method is presented which allows estimation of the tritium remaining in a bed after it has been drained and flushed. Data on specific bed draining and flushing are given.« less
Liu, Weijie; Hao, Yan; Jiang, Jihong; Zhu, Aihua; Zhu, Jingrong; Dong, Zhen
2016-10-01
In this study, bioflocculant produced by Pseudomonas veronii L918 was applied to treat ash-flushing wastewater. The strain L918 could convert the hydrolyzate of peanut hull into bioflocculant, which can effectively reduce the production cost of bioflocculant. The yield of 3.39g/L bioflocculant MBF-L918 was achieved when 300mL/L peanut hull hydrolyzate was used as carbon source. The bioflocculant MBF-L918 contains 77.14% polysaccharides and 4.84% proteins, and the molecular weight (MW) of MBF-L918 is 24.77kDa. Furthermore, MBF-L918 showed good flocculating efficiency of 92.51% to ash-flushing wastewater when 2.83mg/L MBF-L918 was added, and thus achieved the recycling of ash-flushing wastewater. This study reported for the first time that the bioflocculant was produced using peanut hull hydrolyzate and effectively applied in the treatment of coal ash-flushing wastewater. Copyright © 2016 Elsevier Ltd. All rights reserved.
Planetary Probe Entry Atmosphere Estimation Using Synthetic Air Data System
NASA Technical Reports Server (NTRS)
Karlgaard, Chris; Schoenenberger, Mark
2017-01-01
This paper develops an atmospheric state estimator based on inertial acceleration and angular rate measurements combined with an assumed vehicle aerodynamic model. The approach utilizes the full navigation state of the vehicle (position, velocity, and attitude) to recast the vehicle aerodynamic model to be a function solely of the atmospheric state (density, pressure, and winds). Force and moment measurements are based on vehicle sensed accelerations and angular rates. These measurements are combined with an aerodynamic model and a Kalman-Schmidt filter to estimate the atmospheric conditions. The new method is applied to data from the Mars Science Laboratory mission, which landed the Curiosity rover on the surface of Mars in August 2012. The results of the new estimation algorithm are compared with results from a Flush Air Data Sensing algorithm based on onboard pressure measurements on the vehicle forebody. The comparison indicates that the new proposed estimation method provides estimates consistent with the air data measurements, without the use of pressure measurements. Implications for future missions such as the Mars 2020 entry capsule are described.
Generation, recognition, and consistent fusion of partial boundary representations from range images
NASA Astrophysics Data System (ADS)
Kohlhepp, Peter; Hanczak, Andrzej M.; Li, Gang
1994-10-01
This paper presents SOMBRERO, a new system for recognizing and locating 3D, rigid, non- moving objects from range data. The objects may be polyhedral or curved, partially occluding, touching or lying flush with each other. For data collection, we employ 2D time- of-flight laser scanners mounted to a moving gantry robot. By combining sensor and robot coordinates, we obtain 3D cartesian coordinates. Boundary representations (Brep's) provide view independent geometry models that are both efficiently recognizable and derivable automatically from sensor data. SOMBRERO's methods for generating, matching and fusing Brep's are highly synergetic. A split-and-merge segmentation algorithm with dynamic triangular builds a partial (21/2D) Brep from scattered data. The recognition module matches this scene description with a model database and outputs recognized objects, their positions and orientations, and possibly surfaces corresponding to unknown objects. We present preliminary results in scene segmentation and recognition. Partial Brep's corresponding to different range sensors or viewpoints can be merged into a consistent, complete and irredundant 3D object or scene model. This fusion algorithm itself uses the recognition and segmentation methods.
Heparin or 0.9% sodium chloride to maintain central venous catheter patency: a randomized trial.
Schallom, Marilyn E; Prentice, Donna; Sona, Carrie; Micek, Scott T; Skrupky, Lee P
2012-06-01
To compare heparin (3 mL, 10 units/mL) and 0.9% sodium chloride (NaCl, 10 mL) flush solutions with respect to central venous catheter lumen patency. Single-center, randomized, open label trial. Medical intensive care unit and Surgical/Burn/Trauma intensive care unit at Barnes-Jewish Hospital, St. Louis, MO. Three hundred forty-one patients with multilumen central venous catheters. Patients with at least one lumen with a minimum of two flushes were included in the analysis. Patients were randomly assigned within 12 hrs of central venous catheter insertion to receive either heparin or 0.9% sodium chloride flush. The primary outcome was lumen nonpatency. Secondary outcomes included the rates of loss of blood return, inability to infuse or flush through the lumen (flush failure), heparin-induced thrombocytopenia, and catheter-related blood stream infection. Assessment for patency was performed every 8 hrs in lumens without continuous infusions for the duration of catheter placement or discharge from intensive care unit. Three hundred twenty-six central venous catheters were studied yielding 709 lumens for analysis. The nonpatency rate was 3.8% in the heparin group (n = 314) and 6.3% in the 0.9% sodium chloride group (n = 395) (relative risk 1.66, 95% confidence interval 0.86-3.22, p = .136). The Kaplan-Meier analysis for time to first patency loss was not significantly different (log rank = 0.093) between groups. The rates of loss of blood return and flush failure were similar between the heparin and 0.9% sodium chloride groups. Pressure-injectable central venous catheters had significantly greater rates of nonpatency (10.6% vs. 4.3%, p = .001) and loss of blood return (37.0% vs. 18.8%, p <.001) compared to nonpressure-injectable catheters. The frequencies of heparin-induced thrombocytopenia and catheter-related blood stream infection were similar between groups. 0.9% sodium chloride and heparin flushing solutions have similar rates of lumen nonpatency. Given potential safety concerns with the use of heparin, 0.9% sodium chloride may be the preferred flushing solution for short-term use central venous catheter maintenance.
Vinik, A I; Gonin, J; England, B G; Jackson, T; McLeod, M K; Cho, K
1990-06-01
We examined the role of the potent vasoactive kinin substance-P (SP) in flushing derived from various causes. SP was measured in plasma after acetone/ether extraction using an antiserum directed at the carboxy-terminal 5-11 amino acid region of undecapeptide SP. The antiserum had less than 1% cross-reaction with the other neurokinins, neurokinin-A and neuropeptide-K, that derive from the beta-preprotachykinin gene and share carboxy-terminal residues. Basal and pentagastrin-stimulated SP levels were measured in 22 healthy controls, 11 patients with histologically proven carcinoid tumors, 8 patients with tumors other than carcinoid, and 7 patients with idiopathic flushing (IF). Basal SP levels were less than 10 pg/mL in normal subjects. All patients with midgut carcinoid tumors had SP levels greater than 25 pg/mL, as did 7 of 8 patients with noncarcinoid tumors and 5 of 7 patients with IF. Using 50 pg/mL as the cutoff point, the sensitivity was 63% for detection of a tumor, and 100% of nontumor patients were excluded. Pentagastrin administration uniformly induced flushing and caused a rise in SP levels greater than 150 pg/mL in 5 of 10 patients with carcinoid tumors, 3 of 8 with noncarcinoid tumors, and 0 of 7 with IF, i.e. a SP rise of more than 100 pg/mL suggests a tumor. Administration of somatostatin (150 micrograms) 0.5 h before the pentagastrin abolished flushing in all carcinoid patients and reduced SP levels, but not into the normal range. Long term treatment with SMS significantly reduced flushing and lowered SP levels, but did not restore these to normal. We conclude that 90% of patients with carcinoid/noncarcinoid tumor have raised COOH-terminal SP levels. A basal level above 50 pg/mL or a pentagastrin-stimulated rise of more than 100 pg/mL distinguishes carcinoid from IF. The dissociation between SP concentrations and flushing suggests that SP may not be the only kinin involved in the flushing associated with carcinoid tumors.
Seasonality of Central Amazon Forest Leaf Flush Using Tower-Mounted RGB Camera
NASA Astrophysics Data System (ADS)
Wu, J.; Nelson, B. W.; Tavares, J. V.; Valeriano, D. M.; Lopes, A. P.; Marostica, S. F.; Martins, G.; Prohaska, N.; Albert, L.; De Araujo, A. C.; Manzi, A. O.; Saleska, S. R.; Huete, A. R.
2014-12-01
Tower-mounted RGB cameras can contribute data to the debate on seasonality of photosynthesis in Amazon upland forests and to improved modelling of forest response to climate change. In late 2010 we began monitoring upper crown surfaces of ~65 living trees or vines from a 54m tall eddy-flux tower on a well-drained clay-soil plateau. This Central Amazon site (60.2091 W, 2.6092 S) is in a large forest reserve. We deployed a Stardot Netcam XL RGB camera with a 1024 x 768 resolution CMOS sensor, 66o HFOV lens, fixed oblique south view, fixed iris, fixed white balance and auto-exposure. Images were logged every 15 seconds to a passively cooled FitPC2i with heat-tolerant SSD drive. Camera and PC automatically rebooted after power outages. Here we report results for two full years, from 1 Dec 2011 through 30 Nov 2013. Images in six day intervals were selected near local noon for homogeneous diffuse lighting under cloudy sky and for a standard reflected radiance (± 10%). Crowns showing two easily recognized phenophases were tallied: (1) massive flushing of new light-green leaves and (2) complete or nearly complete leaf loss. On average, 60% of live crowns flushed a massive amount of new leaves each year. Each crown flush was completed within 30 days. During the five driest months (Jun-Oct), 44% of all live crowns, on average, exhibited such massive leaf flush. In the five wettest months (Dec-Apr) only 11% of live crowns mass-flushed new leaves. In each year 23% of all live crowns became deciduous, usually a brief (1-2 week) preamble to flushing. Additional crowns lost old dark-green leaves partially and more gradually, becoming semi-deciduous prior to flushing. From these two years of camera data we infer that highly efficient leaves of 2-6 months age (high maximum carboxylation rate) are most abundant from the late dry season (October) through the mid wet season (March). This coincides with peak annual photosynthesis (Gross Ecosystem Productivity) reported for this same Central Amazon site using eddy flux methods.
A Novel Animal Model to Study Hot Flashes: No Effect of GnRH
Albertson, Asher J.; Skinner, Donal C.
2009-01-01
Menopausal hot flushes compromise the quality of life for the majority of women. The physiological mechanisms underlying hot flushes remain poorly understood and the absence of an animal model to investigate hot flushes hinders investigations in this field. We have developed the sheep as a model to study peripheral skin temperature changes. Subjecting sheep to fever-inducing treatments with lipopolysaccharide, a significant (P<0.01) change in ear skin temperature was observed. As a strong correlation between luteinizing hormone pulses and hot flushes has previously been reported, we then determined whether intravenous gonadotropin-releasing hormone (GnRH), at doses sufficient to elevate CSF GnRH concentrations, could modulate ear skin temperature. No effect was observed, suggesting that GnRH per se dose not play a role in the etiology of hot flashes. PMID:19512948
Hamze, Benjamin; Vaillancourt, Régis; Sharp, Diane; Villarreal, Gilda
2016-01-01
The aim of this randomized single-blind study is to compare taste and odor disturbances in patients receiving 0.9% sodium chloride flushes from 2 brands. Seventy-five patients from 6 to 18 years of age received intravenous 0.9% sodium chloride infusions, and 50 healthy volunteers who tasted the 2 brands of 0.9% sodium chloride from prefilled syringes were assessed for taste and/or odor disturbances. Taste or odor disturbances were equally present in patients flushed with MedXL and Becton-Dickinson 0.9% sodium chloride. Disturbances are more frequent when 0.9% sodium chloride is flushed through central venous access devices than through peripheral catheters. No difference between the brands was found when healthy volunteers tasted it orally.
Redefining the stormwater first flush phenomenon.
Bach, Peter M; McCarthy, David T; Deletic, Ana
2010-04-01
The first flush in urban runoff has been an important, yet disputed phenomenon amongst many researchers. The vast differences in the evidence could be solely due to limitations of the first flush current definition and the approach used for its assessment. There is a need for revisiting the first flush theory in the light of its practical applications to urban drainage management practices. We propose that a catchment's first flush behaviour is to be quantified by the runoff volume required to reduce a catchment's stormwater pollutant concentrations to background levels. The proposed method for assessment of this runoff volume starts by finding the average catchment pollutant concentrations for a given increment of discharged volume using a number of event pollutographs. Non-parametric statistics are then used to establish the characteristic pollutograph by pooling statistically indifferent runoff increments (known as slices) together. This allows the identification of the catchment's initial and background pollutant concentrations and for quantification of the first flush volume and its strength. The novel technique was used on seven catchments around Melbourne, Australia, with promising results. Sensitivity to the chosen increment of runoff (for which mean concentrations are calculated) indicated that when dealing with discrete flow-weighted water quality data, a suitable slice size should closely match the flow-weighting of samples. The overall sensitivity to runoff increment and level of significance was found to be negligible. Further research is needed to fully develop this method. Copyright (c) 2010 Elsevier Ltd. All rights reserved.
Perrin, Magali; Rossi, Sergio; Isabel, Nathalie
2017-05-01
Bud and cambial phenology represent the adaptation of species to the local environment that allows the growing season to be maximized while minimizing the risk of frost for the developing tissues. The temporal relationship between the apical and radial meristems can help in the understanding of tree growth as a whole process. The aim of this study was to compare cambial phenology in black spruce (Picea mariana (Mill.) B.S.P.) provenances classified as early and late bud flushing. The different phases of cambial phenology were assessed on wood microcores sampled weekly from April to October in 2014 and 2015 from 61 trees growing in a provenance trial in Quebec, Canada. Trees showing an early bud flush also exhibited early reactivation of xylem differentiation, although an average difference of 12 days for buds corresponded to small although significant differences of 4 days for xylem. Provenances with early bud flush had an early bud set and completed xylem formation earlier than late bud flush provenances. No significant difference in the period of xylem formation and total growth was observed between the flushing classes. Our results demonstrate that the ecotype differentiation of black spruce provenances represented by the phenological adaptation of buds to the local climate corresponds to specific growth dynamics of the xylem. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Espa, Paolo; Brignoli, Maria Laura; Crosa, Giuseppe; Gentili, Gaetano; Quadroni, Silvia
2016-11-01
Sediment flushing may be effective to preserve reservoir storage, but concerns arise about sustainability for downstream freshwater ecosystems. We report on the controlled flushing of approximately 110,000 tons of silt from a 120 Mm(3) reservoir on the Adda River, the main tributary of Lake Como, Italy. Technical constraints prevented flushing during high flows, and the operation had to be spread out over three consecutive years (2010-2012) and, for each year, over a rather long time span (40-50 days). To mitigate the downstream impact, the suspended sediment concentration (SSC) of the evacuated water was controlled by regulating the dislodging works inside the reservoir, increasing the streamflow in the regulated tributaries, and operating an instream settling basin. SSC and water flow as well as benthic macroinvertebrates and trout were monitored as far as 28 km below the reservoir. At the most upstream gauging station, SSC peaked up to 100 g/l and ranged from 3.5 to 8 g/l on average per each operation. Stream quality metrics based on macroinvertebrate data evidenced the impairment due to flushing; however, the benthic community showed high resilience, recovering to pre-flushing conditions in 6-9 months. Trout data were biased by stocking and sport fishing and were more difficult to be interpreted. The trout population wouldn't seem remarkably altered, even if a non-negligible impact could be deduced through pre/post-event sample comparison. Copyright © 2016. Published by Elsevier Ltd.
YoungStar in Wisconsin: Analysis of Data as of July 2014. YoungStar Progress Report #5
ERIC Educational Resources Information Center
Wisconsin Council on Children and Families, 2014
2014-01-01
YoungStar is a program of the Department of Children and Families (DCF) designed to improve the quality of child care for Wisconsin children. YoungStar is designed to: (1) evaluate and rate the quality of care given by child care providers; (2) help parents choose the best child care for their kids; (3) support providers with tools and training to…
Waly, Mostafa I; Guizani, Nejib
2014-09-01
Aluminum (Al) is an environmental toxin that induces oxidative stress in neuronal cells. Mushroom cultivar extract (MCE) acted as a potent antioxidant agent and protects against cellular oxidative stress in human cultured neuronal cells. This study aimed to investigate the neuroprotective effect of MCE against Al-induced neurotoxicity in rat brain. Forty Sprague-Dawley rats were divided into 4 groups (10 rats per group), control group, MCE-fed group, Al-administered group and MCE/Al-treated group. Animals were continuously fed ad-libitum their specific diets for 4 weeks. At the end of the experiment, all rats were sacrificed and the brain tissues were homogenized and examined for biochemical measurements of neurocellular oxidative stress indices [glutathione (GSH), Total Antioxidant Capacity (TAC), antioxidant enzymes and oxidized dichlorofluorescein (DCF)]. Al-administration caused inhibition of antioxidant enzymes and a significant decrease in GSH and TAC levels, meanwhile it positively increased cellular oxidized DCF level, as well as Al concentration in brain tissues. Feeding animals with MCE had completely offset the Al-induced oxidative stress and significantly restrict the Al accumulation in brain tissues of Al-administered rats. The results obtained suggest that MCE acted as a potent dietary antioxidant and protects against Al-mediated neurotoxicity, by abrogating neuronal oxidative stress.
Copiello, Sergio
2016-01-01
The Discounted Cash Flow method is a long since well-known tool to assess the feasibility of investment projects, as the background which shapes a broad range of techniques, from the Cost-Benefit Analysis up to the Life-Cycle Cost Analysis. Its rationale lies in the comparison of deferred values, only once they have been discounted back to the present. The DCF variant proposed here fits into a specific application field. It is well-suited to the evaluations required in order to structure equitable transactions under the umbrella of Public-Private Partnership. •The discount rate relies upon the concept of expected return on equity, instead than on those of weighted average cost of capital, although the latter is the most common reference within the scope of real estate investment valuation.•Given a feasible project, whose Net Present Value is more than satisfactory, we aim to identify the amount of the additional burdens that could be charged to the project, under the condition of keeping the same economically viable.•The DCF variant essentially deals with an optimization problem, which can be solved by means of simple one-shot equations, derived from financial mathematics, or through iterative calculations if additional constraints must be considered.
Wang, Hao; Gardecki, Joseph A.; Ughi, Giovanni J.; Jacques, Paulino Vacas; Hamidi, Ehsan; Tearney, Guillermo J.
2015-01-01
While optical coherence tomography (OCT) has been shown to be capable of imaging coronary plaque microstructure, additional chemical/molecular information may be needed in order to determine which lesions are at risk of causing an acute coronary event. In this study, we used a recently developed imaging system and double-clad fiber (DCF) catheter capable of simultaneously acquiring both OCT and red excited near-infrared autofluorescence (NIRAF) images (excitation: 633 nm, emission: 680nm to 900nm). We found that NIRAF is elevated in lesions that contain necrotic core – a feature that is critical for vulnerable plaque diagnosis and that is not readily discriminated by OCT alone. We first utilized a DCF ball lens probe and a bench top setup to acquire en face NIRAF images of aortic plaques ex vivo (n = 20). In addition, we used the OCT-NIRAF system and fully assembled catheters to acquire multimodality images from human coronary arteries (n = 15) prosected from human cadaver hearts (n = 5). Comparison of these images with corresponding histology demonstrated that necrotic core plaques exhibited significantly higher NIRAF intensity than other plaque types. These results suggest that multimodality intracoronary OCT-NIRAF imaging technology may be used in the future to provide improved characterization of coronary artery disease in human patients. PMID:25909020
Pietrowski, Eweline; Bender, Bianca; Huppert, Jula; White, Robin; Luhmann, Heiko J; Kuhlmann, Christoph R W
2011-01-01
T cells are known for their contribution to the inflammatory element of atherosclerosis. Recently, it has been demonstrated that the Th17 derived cytokine IL-17 is involved in the pro-inflammatory response of vascular smooth muscle cells (VSMC). The aim of the present study was to examine whether reactive oxygen species (ROS) might be involved in this context. The effect of IL-17A on ROS generation was examined using the fluorescent dye 2'7'-dichlorodihydrofluorescein (H(2)DCF) in primary murine VSMC. IL-17A induced an increase in H(2)DCF fluorescence in VSMC, and this effect was blocked by the NAD(P)H-oxidase inhibitor apocynin and siRNA targeting Nox2. The p38-MAPK inhibitors SB203580 and SB202190 dose-dependently reduced the IL-17A induced ROS production. The IL-17A induced release of the pro-inflammatory cytokines IL-6, G-CSF, GM-CSF and MCP-1 from VSMC, as detected by the Luminex technology, was completely abolished by NAD(P)H-oxidase inhibition. Taken together, our data indicate that IL-17A causes the NAD(P)H-oxidase dependent generation of ROS leading to a pro-inflammatory activation of VSMC. Copyright © 2010 S. Karger AG, Basel.
Laboratory Investigations for the Role of Flushing Media in Diamond Drilling of Marble
NASA Astrophysics Data System (ADS)
Bhatnagar, A.; Khandelwal, Manoj; Rao, K. U. M.
2011-05-01
Marble is used as a natural stone for decorative purposes from ages. Marble is a crystalline rock, composed predominantly of calcite, dolomite or serpentine. The presence of impurities imparts decorative pattern and colors. The diamond-based operations are extensively used in the mining and processing of marble. Marble is mined out in the form of blocks of cuboids shape and has to undergo extensive processing to make it suitable for the end users. The processing operation includes slabbing, sizing, polishing, etc. Diamond drilling is also commonly used for the exploration of different mineral deposits throughout the world. In this paper an attempt has been made to enhance the performance of diamond drilling on marble rocks by adding polyethylene-oxide (PEO) in the flushing water. The effect of PEO added with the drilling water was studied by varying different machine parameters and flushing media concentration in the laboratory. The responses were rate of penetration and torque at bit-rock interface. Different physico-mechanical properties of marble were also determined. It was found that flushing water added with PEO can substantially enhance the penetration rates and reduce the torque developed at the bit-rock interface as compared to plain flushing water.
Cysneiros, Denise; Banks, Charles J; Heaven, Sonia; Karatzas, Kimon-Andreas G
2012-11-01
The effect of hydraulic flush and pH control on hydrolysis, Volatile Fatty Acids (VFA) production and profile in anaerobic leach bed reactors was investigated for the first time. Six reactors were operated under different regimes for two consecutive batches of 28days each. Buffering at pH ∼6.5 improved hydrolysis (Volatile Solid (VS) degradation) and VFA production by ∼50%. Butyric and acetic acid were dominant when reactors were buffered, while only butyric acid was produced at low pH. Hydraulic flush enhanced VS degradation and VFA production by ∼15% and ∼32%, respectively. Most Probable Number (MPN) of cellulolytic microorganisms indicated a wash out when hydraulic flush was applied, but pH control helped to counteract this. The highest VS degradation (∼89%), VFA yield (0.84kgCODkg(-1)VS(added)) and theoretical methane potential (0.37m(3)CH(4)kg(-1)VS(added)) were obtained when pH control and hydraulic flush were applied, and therefore, these conditions are recommended. Copyright © 2012 Elsevier Ltd. All rights reserved.
Role of HCA₂ (GPR109A) in nicotinic acid and fumaric acid ester-induced effects on the skin.
Hanson, Julien; Gille, Andreas; Offermanns, Stefan
2012-10-01
Nicotinic acid (NA) and fumaric acid esters (FAE) such as monomethyl fumarate or dimethyl fumarate are drugs that elicit a cutaneous reaction called flushing as a side effect. NA is used to reduce progression of atherosclerosis through its anti-dyslipidemic activity and lipid-independent mechanisms involving immune cells, whereas FAE are used to treat psoriasis via largely unknown mechanisms. Both, NA and FAE, induce flushing by the activation of the G-protein-coupled receptor (GPCR) Hydroxy-carboxylic acid receptor 2 (HCA₂, GPR109A) in cells of the epidermis. While the wanted effects of NA are at least in part also mediated by HCA₂, it is currently not clear whether this receptor is also involved in the anti-psoriatic effects of FAE. The HCA₂-mediated flushing response to these drugs involves the formation of prostaglandins D₂ and E₂ by Langerhans cells and keratinocytes via COX-1 in Langerhans cells and COX-2 in keratinocytes. This review summarizes recent progress in the understanding of the mechanisms underlying HCA₂-mediated flushing, describes strategies to mitigate it and discusses the potential link between flushing, HCA₂ and the anti-psoriatic effects of FAE. Copyright © 2012 Elsevier Inc. All rights reserved.
Toilets Specification and Certification
Recent advancements have allowed toilets to use 1.28 gallons per flush or less while still providing equal or superior performance. This is 20 percent less water than the current federal standard of 1.6 gallons per flush.
30 CFR 57.7807 - Flushing the combustion chamber.
Code of Federal Regulations, 2011 CFR
2011-07-01
... and Rotary Jet Piercing Rotary Jet Piercing-Surface Only § 57.7807 Flushing the combustion chamber. The combustion chamber of a jet drill stem which has been sitting unoperated in a drill hole shall be...
30 CFR 57.7807 - Flushing the combustion chamber.
Code of Federal Regulations, 2010 CFR
2010-07-01
... and Rotary Jet Piercing Rotary Jet Piercing-Surface Only § 57.7807 Flushing the combustion chamber. The combustion chamber of a jet drill stem which has been sitting unoperated in a drill hole shall be...
A selective estrogen receptor modulator for the treatment of hot flushes.
Wallace, Owen B; Lauwers, Kenneth S; Dodge, Jeffrey A; May, Scott A; Calvin, Joel R; Hinklin, Ronald; Bryant, Henry U; Shetler, Pamela K; Adrian, Mary D; Geiser, Andrew G; Sato, Masahiko; Burris, Thomas P
2006-02-09
A selective estrogen receptor modulator (SERM) for the potential treatment of hot flushes is described. (R)-(+)-7,9-difluoro-5-[4-(2-piperidin-1-ylethoxy)phenyl]-5H-6-oxachrysen-2-ol, LSN2120310, potently binds ERalpha and ERbeta and is an antagonist in MCF-7 breast adenocarcinoma and Ishikawa uterine cancer cell lines. The compound is a potent estrogen antagonist in the rat uterus. In ovariectomized rats, the compound lowers cholesterol, maintains bone mineral density, and is efficacious in a morphine dependent rat model of hot flush efficacy.
Performance Characteristics of Flush and Shielded Auxiliary Exits at Mach Numbers of 1.5 to 2.0
NASA Technical Reports Server (NTRS)
Abdalla, Kaleel L.
1959-01-01
The performance characteristics of several flush and shielded auxiliary exits were investigated at Mach numbers of 1.5 to 2.0, and jet pressure ratios from jet off to 10. The results indicate that the shielded configurations produced better overall performance than the corresponding flush exits over the Mach-number and pressure-ratio ranges investigated. Furthermore, the full-length shielded exit was highest in performance of all the configurations. The flat-exit nozzle block provided considerably improved performance compared with the curved-exit nozzle block.
Domanin, Maurizio; Miloro, Riccardo; Romagnoli, Silvia; Basellini, Aldo
2018-03-01
Guidelines now recommend endovenous thermal ablation over open treatment of saphenous incompetence, but flush saphenofemoral ligation and stripping remain relevant when appropriately applied and expertly executed. Complications are rare but could be severe, needing further surgical correction. We report a unique case of a late venous pseudoaneurysm of the great saphenous vein stump after flush saphenofemoral ligation and stripping, successfully treated with surgical sac excision. We highlight the importance of continuous follow-up for patients previously submitted to open venous surgery.
2010-11-30
approved climate zones) ► Dual flush toilets ► 1.5 GPM flow shower heads ► 0.5 GPM flow faucets ► Rainwater harvesting ► Permeable asphalt, permeable...for system with indirect evaporative pre-cooling Sustainability Measures ► Dual flush toilets ► 1.5 GPM flow shower heads, 0.5 GPM flow faucets...daylighting controls with 500 lux setpoint ► Dual flush toilets ►Waterless urinals ► 0.5 GPM flow faucets ► Rainwater harvesting ► Enhanced Commissioning
Hussain, Faruqe; Clasen, Thomas; Akter, Shahinoor; Bawel, Victoria; Luby, Stephen P; Leontsini, Elli; Unicomb, Leanne; Barua, Milan Kanti; Thomas, Brittany; Winch, Peter J
2017-05-25
In rural Bangladesh, India and elsewhere, pour-flush pit latrines are the most common sanitation system. When a single pit latrine becomes full, users must empty it themselves and risk exposure to fresh feces, pay an emptying service to remove pit contents or build a new latrine. Double pit pour-flush latrines may serve as a long-term sanitation option including high water table areas because the pits do not need to be emptied immediately and the excreta decomposes into reusable soil. Double pit pour-flush latrines were implemented in rural Bangladesh for 'hardcore poor' households by a national NGO, BRAC. We conducted interviews, focus groups, and spot checks in two low-income, rural areas of Bangladesh to explore the advantages and limitations of using double pit latrines compared to single pit latrines. The rural households accepted the double pit pour-flush latrine model and considered it feasible to use and maintain. This latrine design increased accessibility of a sanitation facility for these low-income residents and provided privacy, convenience and comfort, compared to open defecation. Although a double pit latrine is more costly and requires more space than a single pit latrine the households perceived this sanitation system to save resources, because households did not need to hire service workers to empty pits or remove decomposed contents themselves. In addition, the excreta decomposition process produced a reusable soil product that some households used in homestead gardening. The durability of the latrine superstructures was a problem, as most of the bamboo-pole superstructure broke after 6-18 months of use. Double pit pour-flush latrines are a long-term improved sanitation option that offers users several important advantages over single pit pour-flush latrines like in rural Bangladesh which can also be used in areas with high water table. Further research can provide an understanding of the comparative health impacts and effectiveness of the model in preventing human excreta from entering the environment.
Flow cytometry for immediate follow-up of drinking water networks after maintenance.
Van Nevel, Sam; Buysschaert, Benjamin; De Roy, Karen; De Gusseme, Bart; Clement, Lieven; Boon, Nico
2017-03-15
Drinking water networks need maintenance every once in a while, either planned interventions or emergency repairs. When this involves opening of the water pipes, precautionary measures need to be taken to avoid contamination of the drinking water at all time. Drinking water suppliers routinely apply plating for faecal indicator organisms as quality control in such a situation. However, this takes at least 21 h of waiting time, which can be crucial when dealing with major supply pipes. A combination of flow cytometric (FCM) bacterial cell counts with FCM fingerprinting techniques is proposed in this study as a fast and sensitive additional technique. In three full scale situations, major supply pipes with 400-1050 mm diameter were emptied for maintenance, shock-chlorinated and flushed with large amounts of clean drinking water before taking back in operation. FCM measurements of the discharged flushing water revealed fast lowering and stabilizing bacterial concentrations once flushing is initiated. Immediate comparison with clean reference drinking water used for flushing was done, and the moment when both waters had similar bacterial concentrations was considered as the endpoint of the necessary flushing works. This was usually after 2-4 h of flushing. FCM fingerprinting, based on both bacteria and FCM background, was used as additional method to verify how similar flushing and reference samples were and yielded similar results. The FCM approved samples were several hours later approved as well by the drinking water supplier after plating and incubation for total Coliforms and Enterococci. These were used as decisive control to set the pipes back in operation. FCM proved to be a more conservative test than plating, yet it yielded immediate results. Application of these FCM methods can therefore avoid long unnecessary waiting times and large drinking water losses. Copyright © 2016 Elsevier Ltd. All rights reserved.
Modeling the Flushing Response to the Construction of a Low Crested Weir in the Banana River
NASA Astrophysics Data System (ADS)
Saberi, A.; Weaver, R. J.
2014-12-01
The ADCIRC hydrodynamic model coupled with a Lagrangian Particle Tracking Model (LPTM) is applied to study circulation in the Banana River. The purpose of this study is to determine the extent to which constructing a low crested weir adjacent to Port Canaveral can improve flushing in this region. The Banana River a 50 km long sub-basin of the Indian River Lagoon (IRL), located on the central-east coast of Florida in Brevard County between Cape Canaveral and Merritt Island. Although Banana River has an outlet to the ocean through the Port Canaveral locks, the locks remain closed when there is no passing vessel resulting in limited circulation, long flushing time and poor water quality. Recent high mortality events of different species, e.g. dolphins, manatees and pelicans in the lagoon ecosystem, can be linked to the decline in the water quality. ADCIRC is used to simulate the hydrodynamic properties of the study area and determine the 2D depth-averaged velocity field for two separate cases: one with only tidal and another with both tidal and meteorological forces considered. Simulations are run, first to establish the baseline hydrodynamics of the unmodified system, and then to predict the effects of modifying the domain. Passive particles are placed in the Banana River portion of our domain, and the movement of these particles is tracked using LPTM for both cases. Flushing and residence time are then computed. Results indicate an improvement in flushing in both the Banana River and the central Indian River Lagoon, driven by an induced southerly current. In the portion of the Banana River to the south of the port complex, tidal flushing time is significantly reduced for the case of modified domain. In this southern region the flushing time based on 50% renewal time, is decreased from 100 days down to 15 days, after the addition of the weir to the domain.
How to Dispose of Unused Medicines
... trash and recycling facility. Flushing Drugs and the Water Supply Some people wonder if it’s okay to flush ... such as rivers and lakes, and in drinking water supplies. “The main way drug residues enter water systems ...
40 CFR 141.803 - Coliform sampling.
Code of Federal Regulations, 2013 CFR
2013-07-01
... the disinfection and flushing frequency recommended by the aircraft water system manufacturer, when... of the aircraft water system is unrestricted. (e) Post disinfection and flushing follow-up sampling....803 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED...
40 CFR 141.803 - Coliform sampling.
Code of Federal Regulations, 2014 CFR
2014-07-01
... the disinfection and flushing frequency recommended by the aircraft water system manufacturer, when... of the aircraft water system is unrestricted. (e) Post disinfection and flushing follow-up sampling....803 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED...
INTERIOR VIEW OF THE PANTRY. SHOWING THE ORIGINAL FLUSH WOOD ...
INTERIOR VIEW OF THE PANTRY. SHOWING THE ORIGINAL FLUSH WOOD CABINET DOORS AND ORIGINAL BIN PULLS ON DRAWERS. VIEW FACING SOUTHWEST. - Hickam Field, Officers' Housing Type L, 702 Julian Avenue, Honolulu, Honolulu County, HI
Simpkins, D.G.; Hubert, W.A.; Wesche, T.A.
2000-01-01
The controlled release of dammed water, designed to produce a flushing flow that would remove fine sediments from spawning habitat in a flow-regulated river, did not displace juvenile rainbow trout Oncorhynchus mykiss (20-25 cm total length) downstream. Of eight naturally spawned (wild) and nine hatchery fish that were radio-tagged, only one wild fish and two hatchery fish were found in different locations after an eight-fold increase in flow. These three fish moved upstream and the greatest movement was 96 m. Cobble and boulder substrates in main-channel pools were thought to provide slow-water-velocity refuges during the flushing flow. Our findings and the findings of other researchers suggest that flushing flows can be conducted to enhance spawning habitat for rainbow trout without causing extensive downstream movements or habitat displacement of small fish in regulated rivers.
NASA Technical Reports Server (NTRS)
Larson, T. J.; Flechner, S. G.; Siemers, P. M., III
1980-01-01
The results of a wind tunnel investigation on an all flush orifice air data system for use on a KC-135A aircraft are presented. The investigation was performed to determine the applicability of fixed all flush orifice air data systems that use only aircraft surfaces for orifices on the nose of the model (in a configuration similar to that of the shuttle entry air data system) provided the measurements required for the determination of stagnation pressure, angle of attack, and angle of sideslip. For the measurement of static pressure, additional flush orifices in positions on the sides of the fuselage corresponding to those in a standard pitot-static system were required. An acceptable but less accurate system, consisting of orifices only on the nose of the model, is defined and discussed.
Seventy-two hours hypothermic intestinal preservation study using a new perfluorocarbon emulsion.
DeRoover, A; Krafft, M P; Deby-Dupont, G; Riess, J; Jacquet, N; Lamy, M; Meurisse, M; D'Silva, M
2001-05-01
We investigated the effect of a perfluorocarbon emulsion (FC) added to the University of Wisconsin (UW) solution on hypothermic (4 degrees C, 12-72h) preservation of rat small bowel grafts. The FC was 90%w/v perfluorooctylbromide, 2%w/v egg yolk phospholipids and 1.4%w/v mixed fluorocarbon-hydrocarbon molecular dowels. Four groups were defined: [1] UW flush and UW storage; [2] UW flush and FC storage; [3] flush with FC diluted 2 times with UW (FU) and FU storage; [4] FU flush and storage in oxygenated FU. Preservation was estimated with a histological score based on villus epithelium adhesion, on villus sloughing and on crypt cell adhesion to the basal membrane. Antioxidant potential was estimated by measurement of total thiol functions (SH) and activities of glutathione-peroxidase (GSH-P), superoxide dismutase (SOD) and catalase. FC in flush improved preservation during the first 24h (p<0.01). Storage in FC appeared superior to UW for the first 24h (p<0.01). Oxygenation (100% O2) of the storage medium yielded superior results at 12h and 24h (p<0.01 and p<0.001 versus group [1] respectively). After 72h, SOD and catalase activities increased in groups [3] and [4], and SOD decreased in group [1] (p<0.05). SH progressively decreased in group [1] (p<0.05) and GSH-P increased at 24 and 48h in groups [3] and [4] (p<0.01). The increase of O2 in the perfusion flush or storage medium ameliorated the preservation status and protected the antioxidant potential of the small bowel.
Goodwin, Carl R.
1991-01-01
Decades of dredging and filling of Florida's low-lying coastal wetlands have produced thousands of miles of residential tidal canals and adjacent waterfront property. Typically, these canals are poorly flushed, and over time, accumulated organic-rich bottom materials, contribute to an increasingly severe degraded water quality. One-dimensional hydrodynamic and constituent-transport models were applied to two dead-end canal systems to determine the effects of canal system interconnection using tide gates on water circulation and constituent flushing. The model simulates existing and possible future circulation and flushing conditions in about 29 miles of the approximately 130 miles of tidally influenced canals in Cape Coral, located on the central west coast of peninsular Florida. Model results indicate that tidal water-level differences between the two canal systems can be converted to kinetic energy, in the form of increased water circulation, but the use of one-way tide gate interconnections. Computations show that construction of from one to four tide gates will cause replacement of a volume of water equivalent to the total volume of canals in both systems in 15 to 9 days, respectively. Because some canals flush faster than others, 47 and 21 percent of the original canal water will remain in both systems 50 days after start of operation of one and four tide gates, respectively. Some of the effects that such increased flushing are expected to have include reduced density stratification and associated dissolved-oxygen depletion in canal bottom waters, increased localized reaeration, and more efficient discharge of stormwater runoff entering the canals.
The impact of recreational boat traffic on Marbled Murrelets (Brachyramphus marmoratus).
Bellefleur, Danielle; Lee, Philip; Ronconi, Robert A
2009-01-01
This study evaluated the impact of small boat traffic on reaction distances of Marbled Murrelets (Brachyramphus marmoratus), in the marine waters of Pacific Rim National Park Reserve, British Columbia, Canada. Observers on moving boats recorded the minimum distance the boat came to murrelets on the water, and any disturbance reaction (fly, dive, no reaction). Out of the 7500 interactions 11.7% flew, 30.8% dove and 58.1% exhibited no flushing reaction. Using a product-limit analysis, we developed curves for the proportion of Marbled Murrelets flushing (dive or flight) as a function of reaction distance. Overall, the majority of Marbled Murrelets waited until boats were within 40 m before reacting, with 25% of the population reacting at 29.2m. A stepwise Cox regression indicated that age, boat speed, and boat density (loaded in that order), significantly affected flushing response. More juveniles flushed than adults (70.1 versus 51.7%), but at closer distances. Faster boats caused a greater proportion of birds to flush, and at further distances (25% of birds flushed at 40 m at speeds > 29 kph versus 28m at speeds <12kph). A stepwise logistic regression on diving and flight responses indicated that birds tended to fly completely out of feeding areas at the approach of boats travelling >28.8 kph and later in the season (July and August). Other secondary variables included; boat density and time of day. Discussion focused on possible management actions such as the application of speed limits, set back distances, and exclusion of boat traffic to protect Marbled Murrelets.
Vacuum Flushing of Sewer Solids
The vacuum sewer and tank cleaning (flushing) technology removes sewer solids from urban drainage systems, such as storage tanks and pipes. This technology is both effective and inexpensive. In addition, it can be considered a true green technology. It operates under atmospheri...
SEWER AND TANK SEDIMENT FLUSHING: CASE STUDIES
The objective of the report summarized here is to demonstrate that sewer system and storage tank flushing that reduces sediment deposition and accumulation is of prime importance to optimizing performance, maintaining structural integrity, and minimizing pollution of receiving wa...
REMEDIATION OF CONTAMINATED SOILS BY SOLVENT FLUSHING
Solvent flushing is a potential technique for remediating a waste disposal/spill site contaminated with organic chemicals. This technique involves the injection of a solvent mixture (e.g., water plus alcohols) that enhances contaminant solubility, reduces the retardation factor, ...
2011-01-01
Background This trial aims to evaluate the effectiveness of a group cognitive behavioural intervention to alleviate menopausal symptoms (hot flushes and night sweats) in women who have had breast cancer treatment. Hot flushes and night sweats are highly prevalent but challenging to treat in this population. Cognitive behaviour therapy has been found to reduce these symptoms in well women and results of an exploratory trial suggest that it might be effective for breast cancer patients. Two hypotheses are tested: Compared to usual care, group cognitive behavioural therapy will: 1. Significantly reduce the problem rating and frequency of hot flushes and nights sweats after six weeks of treatment and at six months post-randomisation. 2. Improve mood and quality of life after six weeks of treatment and at six months post-randomisation. Methods/Design Ninety-six women who have completed their main treatment for breast cancer and who have been experiencing problematic hot flushes and night sweats for over two months are recruited into the trial from oncology and breast clinics in South East London. They are randomised to either six weekly group cognitive behavioural therapy (Group CBT) sessions or to usual care. Group CBT includes information and discussion about hot flushes and night sweats in the context of breast cancer, monitoring and modifying precipitants, relaxation and paced respiration, stress management, cognitive therapy for unhelpful thoughts and beliefs, managing sleep and night sweats and maintaining changes. Prior to randomisation women attend a clinical interview, undergo 24-hour sternal skin conductance monitoring, and complete questionnaire measures of hot flushes and night sweats, mood, quality of life, hot flush beliefs and behaviours, optimism and somatic amplification. Post-treatment measures (sternal skin conductance and questionnaires) are collected six to eight weeks later and follow-up measures (questionnaires and a use of medical services measure) at six months post-randomisation. Discussion MENOS 1 is the first randomised controlled trial of cognitive behavioural therapy for hot flushes and night sweats that measures both self-reported and physiologically indexed symptoms. The results will inform future clinical practice by developing an evidence-based, non-medical treatment, which can be delivered by trained health professionals. Trial Registration Current Controlled Trials ISRCTN13771934 PMID:21281461
NASA Astrophysics Data System (ADS)
Torréton, Jean-Pascal; Rochelle-Newall, Emma; Jouon, Aymeric; Faure, Vincent; Jacquet, Séverine; Douillet, Pascal
2007-09-01
Hydrodynamic modeling can be used to spatially characterize water renewal rates in coastal ecosystems. Using a hydrodynamic model implemented over the semi-enclosed Southwest coral lagoon of New Caledonia, a recent study computed the flushing lag as the minimum time required for a particle coming from outside the lagoon (open ocean) to reach a specific station [Jouon, A., Douillet, P., Ouillon, S., Fraunié, P., 2006. Calculations of hydrodynamic time parameters in a semi-opened coastal zone using a 3D hydrodynamic model. Continental Shelf Research 26, 1395-1415]. Local e -flushing time was calculated as the time requested to reach a local grid mesh concentration of 1/e from the precedent step. Here we present an attempt to connect physical forcing to biogeochemical functioning of this coastal ecosystem. An array of stations, located in the lagoonal channel as well as in several bays under anthropogenic influence, was sampled during three cruises. We then tested the statistical relationships between the distribution of flushing indices and those of biological and chemical variables. Among the variables tested, silicate, chlorophyll a and bacterial biomass production present the highest correlations with flushing indices. Correlations are higher with local e-flushing times than with flushing lags or the sum of these two indices. In the bays, these variables often deviate from the relationships determined in the main lagoon channel. In the three bays receiving significant riverine inputs, silicate is well above the regression line, whereas data from the bay receiving almost insignificant freshwater inputs generally fit the lagoon channel regressions. Moreover, in the three bays receiving important urban and industrial effluents, chlorophyll a and bacterial production of biomass generally display values exceeding the lagoon channel regression trends whereas in the bay under moderate anthropogenic influence values follow the regressions obtained in the lagoon channel. The South West lagoon of New Caledonia can hence be viewed as a coastal mesotrophic ecosystem that is flushed by oligotrophic oceanic waters which subsequently replace the lagoonal waters with water considerably impoverished in resources for microbial growth. This flushing was high enough during the periods of study to influence the distribution of phytoplankton biomass, bacterial production of biomass and silicate concentrations in the lagoon channel as well as in some of the bay areas.
Assessment of remotely sensed chlorophyll-a concentration in Guanabara Bay, Brazil
NASA Astrophysics Data System (ADS)
Oliveira, Eduardo N.; Fernandes, Alexandre M.; Kampel, Milton; Cordeiro, Renato C.; Brandini, Nilva; Vinzon, Susana B.; Grassi, Renata M.; Pinto, Fernando N.; Fillipo, Alessandro M.; Paranhos, Rodolfo
2016-04-01
The Guanabara Bay (GB) is an estuarine system in the metropolitan region of Rio de Janeiro (Brazil), with a surface area of ˜346 km2 threatened by anthropogenic pressure. Remote sensing can provide frequent data for studies and monitoring of water quality parameters, such as chlorophyll-a concentration (Chl-a). Different combination of Medium Resolution Imaging Spectrometer (MERIS) remote sensing reflectance band ratios were used to estimate Chl-a. Standard algorithms such as Ocean Color 3-band, Ocean Color-4 band, fluorescence line height, and maximum chlorophyll index were also tested. The MERIS Chl-a estimates were statistically compared with a dataset of in situ Chl-a (2002 to 2012). Good correlations were obtained with the use of green, red, and near-infrared bands. The best performing algorithm was based on the red (665 nm) and green (560 nm) band ratio, named "RG3" algorithm (r2=0.71, chl-a=62,565*x1.6118). The RG3 was applied to a time series of MERIS images (2003- to 2012). The GB has a high temporal and spatial variability of Chl-a, with highest values found in the wet season (October to March) and in some of the most internal regions of the estuary. Lowest concentrations are found in the central circulation channel due to the flushing of ocean water masses promoted by pumping tide.
Speaker Recognition Using Real vs. Synthetic Parallel Data for DNN Channel Compensation
2016-09-08
Speaker Recognition Using Real vs Synthetic Parallel Data for DNN Channel Compensation Fred Richardson, Michael Brandstein, Jennifer Melot, and...DNNs trained with real Mixer 2 multichannel data perform only slightly better than DNNs trained with synthetic multichannel data for microphone SR on...Mixer 6. Large re- ductions in pooled error rates of 50% EER and 30% min DCF are achieved using DNNs trained on real Mixer 2 data. Nearly the same
2011-03-01
functions of the vignette editor include visualizing the state of the UAS team, creating T&E scenarios, monitoring the UAS team performance, and...These behaviors are then executed by the robot sequentially (Figure 2). A state machine mission editor allows mission builders to use behaviors from the...include control, robotics, distributed applications, multimedia applications, databases, design patterns, and software engineering. Mr. Lenzi is the
Vacuum Flushing of Sewer Solids (Slides)
The vacuum sewer and tank cleaning (flushing) technology removes sewer solids from urban drainage systems, such as storage tanks and pipes. This technology is both effective and inexpensive. In addition, it can be considered a true green technology. It operates under atmospheri...
DOT National Transportation Integrated Search
2007-02-01
This report summarizes the findings of research directed at identifying maintenance solutions for bleeding and : flushed asphalt pavements surfaced with seal coats or surface treatments. Although the basic mechanism associated with : both bleeding an...
BIOSURFACTANT-ENHANCED SOLUBILIZATION OF NAPL MIXTURES. (R827112)
Remediation of nonaqueous phase liquids (NAPLs) by conventional pump-and-treat methods (i.e., water flushing) is generally considered to be ineffective due to low water solubilities of NAPLs and to mass-transfer constraints. Chemical flushing techniques, such as surfactant flushi...
SURFACTANT FLUSH: HOW WELL DID IT WORK?
The Oklahoma Corporation Commission through a contract with Surbec-Art, Inc. of Norman Oklahoma has remediated TPH contamination at a gasoline spill at Golden, Oklahoma. Residual gasoline was removed from the subsurface using a flush of surfactant, followed by in situ bioremedia...
40 CFR 141.803 - Coliform sampling.
Code of Federal Regulations, 2012 CFR
2012-07-01
... aircraft water system, the sampling frequency must be determined by the disinfection and flushing frequency... disinfection and flushing frequency recommended by the aircraft water system manufacturer, when available. Where the aircraft water system manufacturer does not specify a recommended routine disinfection and...
FLUSHING FOR SEWER SEDIMENT, CORROSION, AND POLLUTION CONTROL
This presentation overviews causes of sewer deterioration and heavy pollutant discharges caused by rain events together with a discussion of their control methods. In particular, it covers in-sewer- and combined sewer overflow- (CSO-) storage-tank-flushing systems for removal of ...
NASA Technical Reports Server (NTRS)
Cohn, R. B. (Inventor)
1983-01-01
A mounting device for securing a microphone pick up head flush with respect to the external surfaces of the skin of an aircraft for detecting shock waves passing thereover is described. The mount includes a sleeve mounted internally of the aircraft for capturing and supporting an electronics package having the microphone pick up head attached thereto in a manner such that the head is flush with the external surface of the aircraft skin and a pressure seal is established between the internal and external surfaces of the aircraft skin.
Impact of the shape of the implantable ports on their efficiency of flow (injection and flushing)
Guiffant, Gérard; Flaud, Patrice; Durussel, Jean Jacques; Merckx, Jacques
2014-01-01
Now widely used, totally implantable venous access devices allow mid- and long-term, frequent, repeated, or continuous injection of therapeutic products by vascular, cavitary, or perineural access. The effective flushing of these devices is a key factor that ensures their long-lasting use. We present experimental results and a numerical simulation to demonstrate that the implementation of rounded edge wall cavities improves flushing efficiency. We use the same approaches to suggest that the deposit amount may be reduced by the use of rounded edge wall cavities. PMID:25258561
Flushing syndrome due to mahimahi (scombroid fish) poisoning.
Kim, R
1979-08-01
Scombroid fish poisoning, one of the most common adverse reactions to fish, is also probably one of the most common causes of a flushing syndrome. The reaction usually involves fishes of the Scombridae family but, in Hawaii, the reaction is most often due to mahimahi (Coryphaena hippurus). Onset of the reaction is usually abrupt and commonly associated with a prominent flush resembling a sunburn. Headache, tachye to a toxin with histamine-like properties, which is formed because improper refrigeration enables endogenous bacteria to decarboxylate histidine normally present in dark-meat fishes. Symptoms are usually promptly relieved by parenteral antihistamine therapy.
Use of Electronic Tablets for Patient Education on Flushing Peripherally Inserted Central Catheters.
Petroulias, Patricia L
The purpose of this study was to examine the efficacy of using an electronic tablet to provide patient education for flushing peripherally inserted central catheters (PICCs) as a way to reduce the incidence of occlusion. Eleven patients, newly diagnosed with cancer, participated in a pilot study that used a video on PICC flushing and remote coaching using FaceTime (Apple, Cupertino, CA) to teach patients how to maintain their PICCs in their homes. At the end of the 6-week intervention, no adverse outcomes (occlusions or infections) were noted among the patients who participated in the study.
Extended testing of compression distillation.
NASA Technical Reports Server (NTRS)
Bambenek, R. A.; Nuccio, P. P.
1972-01-01
During the past eight years, the NASA Manned Spacecraft Center has supported the development of an integrated water and waste management system which includes the compression distillation process for recovering useable water from urine, urinal flush water, humidity condensate, commode flush water, and concentrated wash water. This paper describes the design of the compression distillation unit, developed for this system, and the testing performed to demonstrate its reliability and performance. In addition, this paper summarizes the work performed on pretreatment and post-treatment processes, to assure the recovery of sterile potable water from urine and treated urinal flush water.
Space Shuttle reaction control system thruster metal nitrate removal and characterization
NASA Technical Reports Server (NTRS)
Saulsberry, R. L.; Mccartney, P. A.
1993-01-01
The Space Shuttle hypergolic primary reaction control system (PRCS) thrusters continue to fail-leak or fail-off at a rate of approximately 1.5 per flight, attributed primarily to metal nitrate formation in the nitrogen tetroxide (N2O4) pilot operated valves (POV's). The failures have continued despite ground support equipment (GSE) and subsystem operational improvements. As a result, the Johnson Space Center (JSC) White Sands Test Facility (WSTF) performed a study to characterize the contamination in the N204 valves. This study prompted the development and implementation of a highly successful flushing technique using deionized (DI) water and gaseous nitrogen (GN2) to remove the contamination while minimizing Teflon seat damage. Following flushing a comprehensive acceptance test is performed before the thruster is deemed recovered. Between the time WSTF was certified to process flight thrusters (March 1992) and September 1993, a 68 percent thruster recovery rate was achieved. The contamination flushed from these thrusters was analyzed and has provided insight into the corrosion process, which is reported in this publication. Additionally, the long-term performance of 24 flushed thrusters installed in the WSTF Fleet Leader Shuttle reaction control subsystem (RCS) test articles is being assessed. WSTF continues to flush flight and test article thrusters and compile data to investigate metal nitrate formation characteristics in leaking and nonleaking valves.
Bidegain, Maximiliano A; Cubitto, Maria Amelia; Curvetto, Nestor Raul
2015-01-01
Sunflower seed hulls were used as the main component of a solid substrate for the cultivation of the lingzhi or reishi medicinal mushroom Ganoderma lucidum. This study evaluated the effects of supplementing the substrate with olive oil and copper (II) on the mushroom production (MP) parameters and fruiting body total triterpenoid content. The addition of 1.5% olive oil increased total MP by 21.7% (dry basis) in 3 flushes. Copper (60 ppm) increased the daily productivity of the first flush (MP per day) by both reducing the time needed to harvest the crop and increasing the MP. However, the MP at the second and third flushes was reduced. When both supplements were combined, the MP at the first flush was 43% higher than with control treatment. No significant change in mushroom total triterpenoid content was observed by the addition of supplements to the substrate. An increase of 145-155% in the mushroom copper content was obtained by the addition of 60 ppm copper to the substrate. It is thus recommended to use substrate formulations containing both olive oil and copper (II) and harvest just the first flush.
Prevalence of hot flushes and night sweats around the world: a systematic review.
Freeman, E W; Sherif, K
2007-06-01
Many studies have evaluated the relationships between ethnicity and culture, prevalence of menopausal symptoms, and attitudes toward them, but few have assessed menopausal symptoms across cultures world-wide. This paper aims to systematically review the prevalence of hot flushes and night sweats, two prevalent symptoms of menopause, across the menopausal stages in different cultures and considers potential explanations for differences in prevalence rates. Sixty-six papers formed the basis for this review. Studies were organized by geographic region, and results are presented for North America, Europe, East Asia, Southeast Asia, Australia, Latin America, South Asia, Middle East, and Africa. Studies were included if they provided quantitative information on the occurrence of hot flushes. This report focuses on hot flushes and night sweats, the most common menopausal symptoms reported in epidemiologic studies. Studies reviewed indicate that vasomotor symptoms are highly prevalent in most societies. The prevalence of these symptoms varies widely and may be influenced by a range of factors, including climate, diet, lifestyle, women's roles, and attitudes regarding the end of reproductive life and aging. Patterns in hot flush prevalence were apparent for menopausal stages and, to a lesser degree, for regional variation. Caregivers should recognize that variations exist and ask patients specific questions about symptoms and their impact on usual functioning.
Ishigaki, Sayaka; Masui, Kenichi; Kazama, Tomiei
2016-03-01
Circulatory factors modify the onset time of neuromuscular-blocking drugs. Therefore, we hypothesized that infusion of a saline flush immediately after rocuronium administration would shorten the onset time without influencing the duration of the rocuronium effect. Forty-eight patients were randomly allocated to the control or saline flush group. Anesthesia was induced and maintained with propofol and remifentanil, and all patients received 0.6 mg/kg rocuronium in 10 mL of normal saline. In the saline flush group, 20 mL normal saline was immediately infused after rocuronium administration. Neuromuscular blockade was assessed using acceleromyography at the adductor pollicis muscle with train-of-four (TOF) stimulation. The neuromuscular indices for rocuronium were calculated as follows: the latent onset time, defined as the time from the start of rocuronium infusion until first occurrence of depression of the first twitch of the TOF (T1) ≥5%; onset time, defined as the time from the start of rocuronium infusion until first occurrence of depression of the T1 ≥95%; clinical duration, defined as the time from the start of rocuronium administration until T1 recovered to 25% of the final T1 value; recovery index, defined as the time for recovery of T1 from 25% to 75% of the final T1 value; and the total recovery time, defined as the time from the start of rocuronium administration until reaching a TOF ratio of 0.9. Significance was designated at P <0.05. The measured latent onset time and onset time were significantly shorter in the saline flush group than the control group by 15 seconds (95.2% confidence interval, 0-15, P = 0.007) and 15 seconds (0-30, P = 0.018), respectively. Saline flush significantly depressed the T1 height at 30, 45, and 60 seconds after the rocuronium bolus by 17%, 24%, and 14%, respectively. In addition, the recovery phase was significantly prolonged in the saline flush group. The mean clinical duration (5th-95th percentile range) in the saline flush group and control group was 35 minutes (27-63 minutes) and 31 minutes (19-48 minutes; P = 0.032), respectively; the recovery index was 13 minutes (8-25 minutes) and 10 minutes (7-19 minutes; P = 0.019), respectively; and the total recovery time was 61 minutes (44-108 minutes) and 50 minutes (35-93 minutes; P = 0.048), respectively. Administering a 20-mL saline flush immediately after infusion of 0.6 mg/kg rocuronium in 10 mL normal saline shortened the onset time and prolonged the recovery phase of neuromuscular blockade.
DOE Office of Scientific and Technical Information (OSTI.GOV)
de Moura, Yhasmin Mendes; Galvão, Lênio Soares; Hilker, Thomas
The association between spectral reflectance and canopy processes remains challenging for quantifying large-scale canopy phenological cycles in tropical forests. In this paper, we used a tower-mounted hyperspectral camera in an eastern Amazon forest to assess how canopy spectral signals of three species are linked with phenological processes in the 2012 dry season. We explored different approaches to disentangle the spectral components of canopy phenology processes and analyze their variations over time using 17 images acquired by the camera. The methods included linear spectral mixture analysis (SMA); principal component analysis (PCA); continuum removal (CR); and first-order derivative analysis. In addition, threemore » vegetation indices potentially sensitive to leaf flushing, leaf loss and leaf area index (LAI) were calculated: the Enhanced Vegetation Index (EVI), Normalized Difference Vegetation Index (NDVI) and the entitled Green-Red Normalized Difference (GRND) index. We inspected also the consistency of the camera observations using Moderate Resolution Imaging Spectroradiometer (MODIS) and available phenological data on new leaf production and LAI of young, mature and old leaves simulated by a leaf demography-ontogeny model. The results showed a diversity of phenological responses during the 2012 dry season with related changes in canopy structure and greenness values. Because of the differences in timing and intensity of leaf flushing and leaf shedding, Erisma uncinatum, Manilkara huberi and Chamaecrista xinguensis presented different green vegetation (GV) and non-photosynthetic vegetation (NPV) SMA fractions; distinct PCA scores; changes in depth, width and area of the 681-nm chlorophyll absorption band; and variations over time in the EVI, GRND and NDVI. At the end of dry season, GV increased for Erisma uncinatum, while NPV increased for Chamaecrista xinguensis. For Manilkara huberi, the NPV first increased in the beginning of August and then decreased toward September with new foliage. Variations in red-edge position were not statistically significant between the species and across dates at the 95% confidence level. The camera data were affected by view-illumination effects, which reduced the SMA shade fraction over time. When MODIS data were corrected for these effects using the Multi-Angle Implementation of Atmospheric Correction Algorithm (MAIAC), we observed an EVI increase toward September that closely tracked the modeled LAI of mature leaves (3–5 months). Compared to the EVI, the GRND was a better indicator of leaf flushing because the modeled production of new leaves peaked in August and then declined in September following the GRND closely. Finally, while the EVI was more related to changes in mature leaf area, the GRND was more associated with new leaf flushing.« less
de Moura, Yhasmin Mendes; Galvão, Lênio Soares; Hilker, Thomas; ...
2017-09-01
The association between spectral reflectance and canopy processes remains challenging for quantifying large-scale canopy phenological cycles in tropical forests. In this paper, we used a tower-mounted hyperspectral camera in an eastern Amazon forest to assess how canopy spectral signals of three species are linked with phenological processes in the 2012 dry season. We explored different approaches to disentangle the spectral components of canopy phenology processes and analyze their variations over time using 17 images acquired by the camera. The methods included linear spectral mixture analysis (SMA); principal component analysis (PCA); continuum removal (CR); and first-order derivative analysis. In addition, threemore » vegetation indices potentially sensitive to leaf flushing, leaf loss and leaf area index (LAI) were calculated: the Enhanced Vegetation Index (EVI), Normalized Difference Vegetation Index (NDVI) and the entitled Green-Red Normalized Difference (GRND) index. We inspected also the consistency of the camera observations using Moderate Resolution Imaging Spectroradiometer (MODIS) and available phenological data on new leaf production and LAI of young, mature and old leaves simulated by a leaf demography-ontogeny model. The results showed a diversity of phenological responses during the 2012 dry season with related changes in canopy structure and greenness values. Because of the differences in timing and intensity of leaf flushing and leaf shedding, Erisma uncinatum, Manilkara huberi and Chamaecrista xinguensis presented different green vegetation (GV) and non-photosynthetic vegetation (NPV) SMA fractions; distinct PCA scores; changes in depth, width and area of the 681-nm chlorophyll absorption band; and variations over time in the EVI, GRND and NDVI. At the end of dry season, GV increased for Erisma uncinatum, while NPV increased for Chamaecrista xinguensis. For Manilkara huberi, the NPV first increased in the beginning of August and then decreased toward September with new foliage. Variations in red-edge position were not statistically significant between the species and across dates at the 95% confidence level. The camera data were affected by view-illumination effects, which reduced the SMA shade fraction over time. When MODIS data were corrected for these effects using the Multi-Angle Implementation of Atmospheric Correction Algorithm (MAIAC), we observed an EVI increase toward September that closely tracked the modeled LAI of mature leaves (3–5 months). Compared to the EVI, the GRND was a better indicator of leaf flushing because the modeled production of new leaves peaked in August and then declined in September following the GRND closely. Finally, while the EVI was more related to changes in mature leaf area, the GRND was more associated with new leaf flushing.« less
Water reuse at highway rest areas : evaluation phase.
DOT National Transportation Integrated Search
1977-01-01
The limited availability of water and stringent wastewater effluent standards at rest areas led to the development of a water recycle-reuse system to treat flush water from water closets. Flush fluid for rest area water closets accounts for 95% to 97...
Szabo, Jeffrey G; Muhammad, Nur; Heckman, Lee; Rice, Eugene W; Hall, John
2012-04-01
Germination was evaluated as an enhancement to decontamination methods for removing Bacillus spores from drinking water infrastructure. Germinating spores before chlorinating cement mortar or flushing corroded iron was more effective than chlorinating or flushing alone.
Improved diamond coring bits developed for dry and chip-flush drilling
NASA Technical Reports Server (NTRS)
Decker, W. E.; Hampe, W. R.; Hampton, W. H.; Simon, A. B.
1971-01-01
Two rotary diamond bit designs, one operating with a chip-flushing fluid, the second including auger section to remove drilled chips, enhance usefulness of tool for exploratory and industrial core-drilling of hard, abrasive mineral deposits and structural masonry.
FLUSHING FOR SEWER SEDIMENT, CORROSION, AND POLLUTION CONTROL
This paper overviews causes of combined-sewer deterioration and their heavy pollutant discharges caused by rain events together with a discussion of their control methods. In particular, it covers in-sewer and combined-sewer overflow (CSO) storage-tank-flushing systems for removi...
Application of landfill treatment approaches for stabilization of municipal solid waste.
Bolyard, Stephanie C; Reinhart, Debra R
2016-09-01
This research sought to compare the effectiveness of three landfill enhanced treatment approaches aimed at removing releasable carbon and nitrogen after anaerobic landfilling including flushing with clean water (FB 1), leachate recirculation with ex-situ treatment (FB 2), and leachate recirculation with ex-situ treatment and in-situ aeration (FB 3). After extensive treatment of the waste in the FB scenarios, the overall solids and biodegradable fraction were reduced relative to the mature anaerobically treated waste. In terms of the overall degradation, aeration did not provide any advantage over flushing and anaerobic treatment. Flushing was the most effective approach at removing biodegradable components (i.e. cellulose and hemicellulose). Leachate quality improved for all FBs but through different mechanisms. A significant reduction in ammonia-nitrogen occurred in FB 1 and 3 due to flushing and aeration, respectively. The reduction of chemical oxygen demand (COD) in FB 1 was primarily due to flushing. Conversely, the reduction in COD in FBs 2 and 3 was due to oxidation and precipitation during Fenton's Reagent treatment. A mass balance on carbon and nitrogen revealed that a significant fraction still remained in the waste despite the additional treatment provided. Carbon was primarily converted biologically to CH4 and CO2 in the FBs or removed during treatment using Fenton's Reagent. The nitrogen removal occurred through leaching or biological conversion. These results show that under extensive treatment the waste and leachate characteristics did meet published stability values. The minimum stability values achieved were through flushing although FB 2 and 3 were able to improve leachate quality and solid waste characteristics but not to the same extent as FB 1. Copyright © 2016 Elsevier Ltd. All rights reserved.
Haryanto, Bode; Chang, Chien-Hsiang
2015-01-01
In this study, the interfacial properties of biosurfactant rhamnolipid were investigated and were applied to remove adsorbed heavy metal ions from sand surfaces with flushing operations. The surface tension-lowering activity, micelle charge characteristic, and foaming ability of rhamnolipid were identified first. For rhamnolipid in water, the negatively charged characteristic of micelles or aggregates was confirmed and the foaming ability at concentrations higher than 40 mg/L was evaluated. By using the rhamnolipid solutions in a batch washing approach, the potential of applying the interfacial properties of rhamnolipid to remove adsorbed copper ions from sand surfaces was then demonstrated. In rhamnolipid solution flushing operations for sand-packed medium, higher efficiency was found for the removal of adsorbed copper ions with residual type than with inner-sphere interaction type, implying the important role of interaction type between the copper ion and the sand surface in the removal efficiency. In addition, the channeling effect of rhamnolipid solution flow in the sand-packed medium was clearly observed in the solution flushing operations and was responsible for the low removal efficiency with low contact areas between solution and sand. By using rhamnolipid solution with foam to flush the sand-packed medium, one could find that the channeling effect of the solution flow was reduced and became less pronounced with the increase in the rhamnolipid concentration, or with the enhanced foaming ability. With the reduced channeling effect in the flushing operations, the removal efficiency for adsorbed copper ions was significantly improved. The results suggested that the foam-enhanced rhamnolipid solution flushing operation was efficient in terms of surfactant usage and operation time.
Photosynthetic thermotolerance of woody savanna species in China is correlated with leaf life span
Zhang, Jiao-Lin; Poorter, L.; Hao, Guang-You; Cao, Kun-Fang
2012-01-01
Background and Aims Photosynthetic thermotolerance (PT) is important for plant survival in tropical and sub-tropical savannas. However, little is known about thermotolerance of tropical and sub-tropical wild plants and its association with leaf phenology and persistence. Longer-lived leaves of savanna plants may experience a higher risk of heat stress. Foliar Ca is related to cell integrity of leaves under stresses. In this study it is hypothesized that (1) species with leaf flushing in the hot-dry season have greater PT than those with leaf flushing in the rainy season; and (2) PT correlates positively with leaf life span, leaf mass per unit area (LMA) and foliar Ca concentration ([Ca]) across woody savanna species. Methods The temperature-dependent increase in minimum fluorescence was measured to assess PT, together with leaf dynamics, LMA and [Ca] for a total of 24 woody species differing in leaf flushing time in a valley-type savanna in south-west China. Key Results The PT of the woody savanna species with leaf flushing in the hot-dry season was greater than that of those with leaf flushing in the rainy season. Thermotolerance was positively associated with leaf life span and [Ca] for all species irrespective of the time of flushing. The associations of PT with leaf life span and [Ca] were evolutionarily correlated. Thermotolerance was, however, independent of LMA. Conclusions Chinese savanna woody species are adapted to hot-dry habitats. However, the current maximum leaf temperature during extreme heat stress (44·3 °C) is close to the critical temperature of photosystem II (45·2 °C); future global warming may increase the risk of heat damage to the photosynthetic apparatus of Chinese savanna species. PMID:22875810
Modulation of magmatic processes by carbon dioxide
NASA Astrophysics Data System (ADS)
Caricchi, L.; Sheldrake, T. E.; Blundy, J. D.
2017-12-01
Volatile solubility in magmas increases with pressure, although the solubility of CO2 is much lower than that of H2O. Consequently, magmas rising from depth release CO2-rich fluids, which inevitably interact with H2O-poor magmas in the upper crust (CO2-flushing). CO2-flushing triggers the exsolution of H2O-rich fluids, leading to an increase of volume and magma crystallisation. While the analyses of eruptive products demonstrates that this process operates in virtually all magmatic system, its impact on magmatic and volcanic processes has not been quantified. Here we show that depending on the initial magma crystallinity, and the depth of magma storage, CO2-flushing can lead to volcanic eruptions or promote conditions that favour the impulsive release of mineralising fluids. Our calculations show that the interaction between a few hundred ppm of carbonic fluids, and crystal-poor magmas stored at shallow depths, produces rapid pressurisation that can potentially lead to an eruption. Further addition of CO2 increases magma compressibility and crystallinity, reducing the potential for volcanic activity, promoting the formation of ore deposits. Increasing the depth of fluid-magma interaction dampens the impact of CO2-flushing on the pressurisation of a magma reservoir. CO2-flushing may result in surface inflation and increases in surface CO2 fluxes, which are commonly considered signs of an impending eruption, but may not necessarily result in eruption depending on the initial crystallnity and depth of the magmatic reservoir. We propose that CO2-flushing is a powerful agent modulating the pressurisation of magma reservoirs and the release of mineralising fluids from upper crustal magma reservoirs.
Microbial contamination of dental unit waterlines: short- and long-term effects of flushing.
Santiago, J I; Huntington, M K; Johnston, A M; Quinn, R S; Williams, J F
1994-01-01
The extensive microbial contamination of DUW in this study is consistent with that described in previous reports. Comparisons with other common public potable water sources emphasize the relatively high concentrations of microorganisms in DUW, and the low numbers of bacteria in most domestic water samples. Microscopic evidence of amebas and worms in DUW reinforces the need for further qualitative and quantitative studies of these contaminants of dental tubing biofilm. In most cases, flushing for two minutes reduced microbial concentrations in DUW. However, in a few cases, concentrations rose; in others, the reductions were negligible. Moreover, after 30 minutes of stasis, or use of the waterline in a routine dental procedure, microbial counts were frequently restored to preflush levels or higher. The longer-term ineffectiveness 30 minutes after flushing is understandable when the hydrodynamics of laminar flow of water in narrow-bore tubing are considered. Biofilm on the tubing wall remains intact during flushes and quickly generates more bacteria during stasis. Increased bacterial concentrations after flushing probably result from sloughing of biofilm from the tubing wall because of stretching and movement of the line during routine use. These two phenomena undermine the benefits of routine water flushes. It is a common belief that bacterial levels build to extremes during overnight or weekend stasis; we observed more variation in contamination levels during the workday than between overnight stasis and typical workday samples. The presence of hemolytic staphylococci and streptococci in water samples from lines that were supplied only from sterile water reservoirs adds to the growing evidence that part of the microbial flora in DUWLs may be derived from patients' mouths. Additional prophylactic measures to limit bacterial contamination in DUW should be implemented according to standard principles used in other medical fluid delivery devices.
Mechanical characteristics of plastic base Ports and impact on flushing efficacy.
Guiffant, Gérard; Flaud, Patrice; Royon, Laurent; Burnet, Espérie; Merckx, Jacques
2017-01-01
Three types of totally implantable venous access devices, Ports, are currently in use: titanium, plastic (polyoxymethylene, POM), and mixed (titanium base with a POM shell). Physics theory suggests that the interaction between a non-coring needle (NCN, made of stainless steel) and a plastic base would lead to the stronger material (steel) altering the more malleable material (plastic). To investigate whether needle impacts can alter a plastic base's surface, thus potentially reducing flushing efficacy. A Port made of POM was punctured 200 times with a 19-gauge NCN. Following the existing guidelines, the needle tip pricked the base with each puncture. The Port's base was then examined using a two-dimensional optical instrument, and a bi-dimensional numerical simulation using COMSOL ® was performed to investigate potential surface irregularities and their impact on fluid flow. Each needle impact created a hole (mean depth, 0.12 mm) with a small bump beside it (mean height, 0.02 mm) the Reynolds number Re k ≈10. A numerical simulation of the one hole/bump set showed that the flushing efficacy was 60% that of flushing along a flat surface. In clinical practice, the number of times a Port is punctured depends on patient and treatment characteristics, but each needle impact on the plastic base may increase the risk of decreased flushing effectiveness. Therefore, the more a plastic Port is accessed, the greater the risk of microorganisms, blood products, and medication accumulation. Multiple needle impacts created an irregular surface on the Port's base, which decreased flushing efficacy. Clinical investigation is needed to determine whether plastic base Ports are associated with an increased risk of Port infection and occlusion compared to titanium base Ports.
DOT National Transportation Integrated Search
2009-06-01
The primary objective of this study was to design and test a first flush-based stormwater treatment device for elevated linear transportation projects/roadways that is capable of complying with MS4 regulations. The innovative idea behind the device i...
21 CFR 225.65 - Equipment cleanout procedures.
Code of Federal Regulations, 2010 CFR
2010-04-01
...) DRUGS: GENERAL CURRENT GOOD MANUFACTURING PRACTICE FOR MEDICATED FEEDS Product Quality Control § 225.65 Equipment cleanout procedures. (a) Adequate cleanout procedures for all equipment used in the manufacture... sequential production of feeds. (2) If flushing is utilized, the flush material shall be properly identified...
46 CFR 194.15-11 - Flushing systems.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 7 2010-10-01 2010-10-01 false Flushing systems. 194.15-11 Section 194.15-11 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OCEANOGRAPHIC RESEARCH VESSELS HANDLING, USE, AND CONTROL OF EXPLOSIVES AND OTHER HAZARDOUS MATERIALS Chemistry Laboratory and Scientific Laboratory...
40 CFR 141.804 - Aircraft water system operations and maintenance plan.
Code of Federal Regulations, 2010 CFR
2010-07-01
...) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS Aircraft Drinking Water Rule... must include the following requirements for procedures for disinfection and flushing of aircraft water system. (i) The air carrier must conduct disinfection and flushing of the aircraft water system in...
In situ flushing groundwater remediation technologies, such as cosolvent flushing, rely on the stability of the interface between the resident and displacing fluids for efficient removal of contaminants. Contrasts in density and viscosity between the resident and displacing flui...
46 CFR 194.15-11 - Flushing systems.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 7 2013-10-01 2013-10-01 false Flushing systems. 194.15-11 Section 194.15-11 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OCEANOGRAPHIC RESEARCH VESSELS HANDLING, USE, AND CONTROL OF EXPLOSIVES AND OTHER HAZARDOUS MATERIALS Chemistry Laboratory and Scientific Laboratory...
SEWER AND TANK FLUSHING FOR CORROSION AND POLLUTION CONTROL
This paper presents an overview of the causes of sewer deterioration and control methods that can prevent or arrest this deterioration. articular, the paper addresses the use of inline- and combined sewer overflow (CSO) storage tank-flushing systems for removing sediments and mi...
Muhammad, Nur; Heckman, Lee; Rice, Eugene W.; Hall, John
2012-01-01
Germination was evaluated as an enhancement to decontamination methods for removing Bacillus spores from drinking water infrastructure. Germinating spores before chlorinating cement mortar or flushing corroded iron was more effective than chlorinating or flushing alone. PMID:22267659
SEWER AND TANK FLUSHING FOR SEDIMENT, CORROSION AND POLLUTION CONTROL
This paper presents an overview of causes of sewer deterioration together with a discussion of control methods that can prevent or arrest this deterioration. In particular, the paper covers inline- and combined sewer overflow- (CSO) storage-tank-flushing systems for removal of se...
Maboreke, Hazel R; Feldhahn, Lasse; Bönn, Markus; Tarkka, Mika T; Buscot, Francois; Herrmann, Sylvie; Menzel, Ralph; Ruess, Liliane
2016-08-12
Pedunculate oak (Quercus robur L.), an important forest tree in temperate ecosystems, displays an endogenous rhythmic growth pattern, characterized by alternating shoot and root growth flushes paralleled by oscillations in carbon allocation to below- and aboveground tissues. However, these common plant traits so far have largely been neglected as a determining factor for the outcome of plant biotic interactions. This study investigates the response of oak to migratory root-parasitic nematodes in relation to rhythmic growth, and how this plant-nematode interaction is modulated by an ectomycorrhizal symbiont. Oaks roots were inoculated with the nematode Pratylenchus penetrans solely and in combination with the fungus Piloderma croceum, and the systemic impact on oak plants was assessed by RNA transcriptomic profiles in leaves. The response of oaks to the plant-parasitic nematode was strongest during shoot flush, with a 16-fold increase in the number of differentially expressed genes as compared to root flush. Multi-layered defence mechanisms were induced at shoot flush, comprising upregulation of reactive oxygen species formation, hormone signalling (e.g. jasmonic acid synthesis), and proteins involved in the shikimate pathway. In contrast during root flush production of glycerolipids involved in signalling cascades was repressed, suggesting that P. penetrans actively suppressed host defence. With the presence of the mycorrhizal symbiont, the gene expression pattern was vice versa with a distinctly stronger effect of P. penetrans at root flush, including attenuated defence, cell and carbon metabolism, likely a response to the enhanced carbon sink strength in roots induced by the presence of both, nematode and fungus. Meanwhile at shoot flush, when nutrients are retained in aboveground tissue, oak defence reactions, such as altered photosynthesis and sugar pathways, diminished. The results highlight that gene response patterns of plants to biotic interactions, both negative (i.e. plant-parasitic nematodes) and beneficial (i.e. mycorrhiza), are largely modulated by endogenous rhythmic growth, and that such plant traits should be considered as an important driver of these relationships in future studies.
Contrasts in Flushing Patterns Among Solutes
NASA Astrophysics Data System (ADS)
Shanley, J. B.; Sebestyen, S. D.; Boyer, E. W.; Ross, D. S.
2005-12-01
High-frequency sampling since 1991 at the 41-ha forested W-9 catchment at Sleepers River, Vermont provides a wealth of data to evaluate catchment flushing responses. Snowmelt and rain-on-snow account for about half the annual flow at Sleepers River during a 6-week period in early spring. Summer and fall storms produce frequent high-flows of short duration. Flushing of weathering products (Ca, Mg, Na, K, SO4 ANC, Si) is generally supply-limited, and is masked by rapid dilution with meteoric and soil water during events. In contrast, flushing dominates the stream dynamics of atmospheric and pedogenic solutes (NO3, DOC, Hg), causing concentration increases with increasing flow. During snowmelt, NO3 peaks well before the peak in discharge, whereas DOC tracks discharge closely and peaks concurrently. These patterns suggest that NO3 is supply-limited and DOC is transport-limited; W-9 is not N saturated and the available NO3 supply is readily leached from the soil, whereas stream DOC progressively increases as rising water tables and expanding saturated areas connect with new source areas. In summer storms, DOC and NO3 both peak simultaneously with discharge. Unlike DOC, however, NO3 concentrations are attenuated with subsequent storms that follow within a few days, consistent with a depletion of the NO3 pool available for flushing as observed during snowmelt. Sleepers River contrasts with the Snake River in Colorado, where NO3 and DOC reverse roles; DOC peaks early in snowmelt and may be supply-limited due to the paucity of organic matter. An ample supply of NO3 is available due to N saturation and N fixation, but NO3 may be transport-limited due to primary N sources in talus deposits far from the stream. Hg is an atmospheric solute that accumulates in soils because of its affinity for organic matter, and is flushed by high flows, mostly in association with suspended sediment. The concept of flushing provides a useful context for understanding the variable responses of solutes to the expansion of catchment saturation during high flow events.
NASA Astrophysics Data System (ADS)
Henderson, Douglas; Quintana, Jacqueline; Sokołowski, Stefan
1995-03-01
A comparison of Percus-Yevick-Pynn-Lado model theory and a density functional (DF) theory of nonuniform fluids of nonspherical particles is performed. The DF used is a new generalization of Tarazona's theory. The conclusion is that DF theory provides a preferable route to describe the system under consideration. Its accuracy can be improved with better approximation for the direct correlation function (DCF) for bulk system.
Weighted Scholarship Selection Model
1986-04-01
AND DCf CDN MAORMAIO E ALENER J.86-6 MA 12 1986 s . ir.- - -- - DISCLAIMER The views and conclusions expressed in this document are those of the... 12 PERSONAL AUTHOR(S) Callender, lisrion E, ., Major, USNF 1. 13o. TYPE OF REPORT 13b. TIME COVEREtJ 14. DATE OF REPORT IYr.. Mo.. Dayl I11...training specialist . In 1971, Major Callender was selected to be a member of the U.S. Air Force Aerial Demonstration Squadron; the "Thunderbirds". In
Multi-Scale Modeling of Novel Hall Thrusters: Understanding Physics of CHT and DCF Thrusters
2011-12-30
thrusters having over 40 years of flight heritage (the first variant, SPT -50, was flown aboard the Soviet Meteor spacecraft in 1971), the community...symmetric sheath. This finding was touched upon in our previous work.14 The walls of this SPT -type thruster are made of a dielectric material. The...One theory of SPT operation suggests that electron impacts of the dielectric material result in emission of secondary electrons from the material
Time-Dependent Simulations of Incompressible Flow in a Turbopump Using Overset Grid Approach
NASA Technical Reports Server (NTRS)
Kiris, Cetin; Kwak, Dochan
2001-01-01
This viewgraph presentation provides information on mathematical modelling of the SSME (space shuttle main engine). The unsteady SSME-rig1 start-up procedure from the pump at rest has been initiated by using 34.3 million grid points. The computational model for the SSME-rig1 has been completed. Moving boundary capability is obtained by using DCF module in OVERFLOW-D. MPI (Message Passing Interface)/OpenMP hybrid parallel code has been benchmarked.
Guiffant, Gérard; Durussel, Jean Jacques; Flaud, Patrice; Vigier, Jean Pierre; Merckx, Jacques
2012-01-01
The use of totally implantable venous access devices developed as a medical device allowing mid- and long-term, frequent, repeated, or continuous injection of therapeutic products, by vascular, cavitary, or perineural access. The effective flushing of these devices is a central element to assure long-lasting use. Our experimental work demonstrates that directing the Huber point needle opening in the diametrically opposite direction of the implantable port exit channel increases the flushing efficiency. These results are consolidated by numerical computations, which support recommendations not only for their maintenance, but also for their use.
Guiffant, Gérard; Durussel, Jean Jacques; Flaud, Patrice; Vigier, Jean Pierre; Merckx, Jacques
2012-01-01
The use of totally implantable venous access devices developed as a medical device allowing mid- and long-term, frequent, repeated, or continuous injection of therapeutic products, by vascular, cavitary, or perineural access. The effective flushing of these devices is a central element to assure long-lasting use. Our experimental work demonstrates that directing the Huber point needle opening in the diametrically opposite direction of the implantable port exit channel increases the flushing efficiency. These results are consolidated by numerical computations, which support recommendations not only for their maintenance, but also for their use. PMID:23166455
Low cost microfluidic device based on cotton threads for electroanalytical application.
Agustini, Deonir; Bergamini, Márcio F; Marcolino-Junior, Luiz Humberto
2016-01-21
Microfluidic devices are an interesting alternative for performing analytical assays, due to the speed of analyses, reduced sample, reagent and solvent consumption and less waste generation. However, the high manufacturing costs still prevent the massive use of these devices worldwide. Here, we present the construction of a low cost microfluidic thread-based electroanalytical device (μTED), employing extremely cheap materials and a manufacturing process free of equipment. The microfluidic channels were built with cotton threads and the estimated cost per device was only $0.39. The flow of solutions (1.12 μL s(-1)) is generated spontaneously due to the capillary forces, eliminating the use of any pumping system. To demonstrate the analytical performance of the μTED, a simultaneous determination of acetaminophen (ACT) and diclofenac (DCF) was performed by multiple pulse amperometry (MPA). A linear dynamic range (LDR) of 10 to 320 μmol L(-1) for both species, a limit of detection (LOD) and a limit of quantitation (LOQ) of 1.4 and 4.7 μmol L(-1) and 2.5 and 8.3 μmol L(-1) for ACT and DCF, respectively, as well as an analytical frequency of 45 injections per hour were reached. Thus, the proposed device has shown potential to extend the use of microfluidic analytical devices, due to its simplicity, low cost and good analytical performance.
Characterization of Fluorescent Polystyrene Microspheres for Advanced Flow Diagnostics
NASA Technical Reports Server (NTRS)
Maisto, Pietro M. F.; Lowe, K. Todd; Byun, Guibo; Simpson, Roger; Vercamp, Max; Danley, Jason E.; Koh, Brian; Tiemsin, Pacita; Danehy, Paul M.; Wohl, Christopher J.
2013-01-01
Fluorescent dye-doped polystyrene latex microspheres (PSLs) are being developed for velocimetry and scalar measurements in variable property flows. Two organic dyes, Rhodamine B (RhB) and dichlorofluorescence (DCF), are examined to assess laser-induced fluorescence (LIF) properties for flow imaging applications and single-shot temperature measurements. A major interest in the current research is the application of safe dyes, thus DCF is of particular interest, while RhB is used as a benchmark. Success is demonstrated for single-point laser Doppler velocimetry (LDV) and also imaging fluorescence, excited via a continuous wave 2 W laser beam, for exposures down to 10 ms. In contrast, when exciting with a pulsed Nd:YAG laser at 200 mJ/pulse, no fluorescence was detected, even when integrating tens of pulses. We show that this is due to saturation of the LIF signal at relatively low excitation intensities, 4-5 orders of magnitude lower than the pulsed laser intensity. A two-band LIF technique is applied in a heated jet, indicating that the technique effectively removes interfering inputs such as particle diameter variation. Temperature measurement uncertainties are estimated based upon the variance measured for the two-band LIF intensity ratio and the achievable dye temperature sensitivity, indicating that particles developed to date may provide about +/-12.5 C precision, while future improvements in dye temperature sensitivity and signal quality may enable single-shot temperature measurements with sub-degree precision.
Learning Team Review 2016-0001: Installing Outlets for Programmatic Equipment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dunwoody, John Tyler; Obrey, Kimberly Ann; Bridgewater, Jon S.
The purpose of a Learning Team is to transfer and communicate the information into operational feedback and improvement. We want to pay attention to the small things that go wrong because they are often early warning signals and may provide insight into the health of the whole system. An ESR was placed in the October of 2015 to move/install a number of 120V and 208V outlets in 455-104B to support programmatic furnace needs. Electrical design review was completed for ESR 22217 on February 22, 2016 and a Design Change Form completed describing the modification needed as: demolish 1 existing receptaclemore » and circuit leaving conduit and jbox for use to install new receptacle and 5 new receptacles/circuits are required and one existing receptacle is to be relocated, listed under FSR 149229. The FSR scope of work was written:: Please have the Electricians come out to perform demolition (1ea.), installation (6ea.)& relocation (1ea.) of receptacles / circuits. ESR 22217 & DCF-16-35-0455-1281 is in place for this work. Coordinate final receptacle locations with Laboratory Resident. Contact John Dunwoody or O-MC for this information. WO# 545580-01 was signed on April 20, 2016.: Electricians to perform demolition, installation, & relocation of receptacles / circuits PER attached DCF-16-0455-1281-SK-1.« less
Combining OCT and a fluorescence intensity imaging method for atherosclerosis detection
NASA Astrophysics Data System (ADS)
Liang, Shanshan; Saidi, Arya; Jing, Joe; Liu, Gangjun; Yin, Jiechen; Narula, Jagat; Chen, Zhongping
2012-02-01
Coronary heart disease (like myocardial infarction) is caused by atherosclerosis. It cause over 30% of all deaths in North America and are the most common cause of death in European men under 65 years of age and the second most common cause in women. To diagnose this atherosclerosis before it gets rupture is the most effect way to increase the chance of survival for patients who suffer from this disease. The crucial tusk is how to find out vulnerable plaques. In resent years optical coherence tomography (OCT) has become a very useful tool for intravascular imaging, since it has high axial and transverse resolution. OCT can tell the detail structure inside the plaque like the thickness of plaque cap which is an important factor to identify vulnerable plaques. But we still need to find out the biochemical characteristics that is unique for vulnerable plaques (like inflammation). Fluorescence molecular imaging is a standard way to exam the biochemical property of biological samples. So we integrate these two techniques together into one probe. Our probe is comprised of a double-clad fiber (DCF) and a grin lens, and rotates with a micro mirror in front. The single-mode inner core of the DCF transmits both OCT and fluorescence excitation light, and the multimode inner cladding is used to detect fluorescence signal. In vitro result shows that this is a possible way for more accurate diagnose of vulnerable plaques.
Oxidative damage in keratinocytes exposed to cigarette smoke and aldehydes.
Avezov, Katia; Reznick, Abraham Z; Aizenbud, Dror
2014-06-01
Cigarette smoke (CS) is a significant environmental source of human exposure to chemically active saturated (acetaldehyde) and α,β-unsaturated aldehydes (acrolein) inducing protein carbonylation and dysfunction. The exposure of oral tissues to environmental hazards is immense, especially in smokers. The objectives of the current study were to examine the effect of aldehydes originating from CS on intracellular proteins of oral keratinocytes and to observe the antioxidant response in these cells. Intracellular protein carbonyl modification under CS, acrolein and acetaldehyde exposure in the HaCaT keratinocyte cell line, representing oral keratinocytes was examined by Western blot. Possible intracellular enzymatic dysfunction under the above conditions was examined by lactate dehydrogenase (LDH) activity assay. Oxidative stress response was investigated, by DCF (2,7-dichlorodihydrofluorescein) assay and GSH (glutathione) oxidation. Intracellular protein carbonyls increased 5.2 times after CS exposure and 2.7 times after exposure to 1 μmol of acrolein. DCF assay revealed an increase of fluorescence intensity 3.2 and 3.1 times after CS and acrolein exposure, respectively. CS caused a 72.5% decrease in intracellular GSH levels compared to controls. Activity of intracellular LDH was preserved. α,β-Unsaturated aldehydes from CS are capable of intracellular protein carbonylation and have a role in intracellular oxidative stress elevation in keratinocytes, probably due to the reduction in GSH levels. Copyright © 2014 Elsevier Ltd. All rights reserved.
Odor control in swine buildings: recycle flush vs. automated scraper
USDA-ARS?s Scientific Manuscript database
A research project was conducted to compare odor concentrations in exhaust of traditional flush barns and barns equipped with automated scrapers. The study was conducted at commercial tunnel-ventilated swine barns in northwest Missouri. Odor samples were collected from the barn exhaust in polyvinyl ...
32. INTERIOR OF STORM PORCH ADDITION SHOWING FLUSH SIDEEXIT DOOR ...
32. INTERIOR OF STORM PORCH ADDITION SHOWING FLUSH SIDEEXIT DOOR AT PHOTO LEFT CENTER AND 1-LIGHT OVER 1LIGHT SASH WINDOW THROUGH WEST WALL AT PHOTO RIGHT. VIEW TO SOUTH. - Rush Creek Hydroelectric System, Clubhouse Cottage, Rush Creek, June Lake, Mono County, CA
APPENDIX C - ADDITIONAL INFORMATION ON FLUSHING IN ESTUARIES
Water residence time is an important determinant of the sensitivity of the response of estuaries and other water bodies to nutrient loading. A variety of terms such as residence time, flushing time, transit time, turnover time, and age are used to describe time scales for transpo...
CONTROLLED RELEASE, BLIND TEST OF DNAPL REMEDIATION BY ETHANOL FLUSHING
A dense nonaqueous phase liquid (DNAPL) source zone was established within a sheet-pile
isolated cell through a controlled release of perchloroethylene (PCE) to evaluate DNAPL
remediation by in-situ cosolvent flushing. Ethanol was used as the cosolvent, and the main remedia...
Ferraro, Alberto; Fabbricino, Massimiliano; La Marca, Agostino; Panico, Antonio; Spasiano, Danilo; Tognacchini, Alice; Pirozzi, Francesco
2018-01-01
This paper presents the results of an experimental study aimed at investigating the effect of operative parameters on the efficiency of a soil flushing process, conducted on real contaminated soil containing high amounts of Cu and Zn. Soil flushing tests were carried out with Ethylenediamine-N,N′-disuccinic acid (EDDS) as a flushing agent due to its high biodegradability and environmentally friendly characteristics. Process parameters such as Empty-Bed Contact Time (EBCT) and EDDS solution molarity were varied from 21–33 h and from 0.36–3.6 mM, respectively. Effects on the mobility of cations such as Fe and Mn were also investigated. Results showed that very high performances can be obtained at [EDDS] = 3.6 mM and EBCT = 33 h. In these conditions, in fact, the amount of removed Cu was 53%, and the amount of removed Zn was 46%. Metal distribution at different depths from the top surface revealed that Cu has higher mobility than Zn. The process results were strongly dependent on the exchange of metals due to the different stability constants of the EDDS complexes. Finally, results from a comparative study showed that soil washing treatment reached the same removal efficiency of the flushing process in a shorter time but required a larger amount of the EDDS solution. PMID:29562649
Race, Marco; Ferraro, Alberto; Fabbricino, Massimiliano; La Marca, Agostino; Panico, Antonio; Spasiano, Danilo; Tognacchini, Alice; Pirozzi, Francesco
2018-03-18
This paper presents the results of an experimental study aimed at investigating the effect of operative parameters on the efficiency of a soil flushing process, conducted on real contaminated soil containing high amounts of Cu and Zn. Soil flushing tests were carried out with Ethylenediamine- N , N '-disuccinic acid (EDDS) as a flushing agent due to its high biodegradability and environmentally friendly characteristics. Process parameters such as Empty-Bed Contact Time (EBCT) and EDDS solution molarity were varied from 21-33 h and from 0.36-3.6 mM, respectively. Effects on the mobility of cations such as Fe and Mn were also investigated. Results showed that very high performances can be obtained at [EDDS] = 3.6 mM and EBCT = 33 h. In these conditions, in fact, the amount of removed Cu was 53%, and the amount of removed Zn was 46%. Metal distribution at different depths from the top surface revealed that Cu has higher mobility than Zn. The process results were strongly dependent on the exchange of metals due to the different stability constants of the EDDS complexes. Finally, results from a comparative study showed that soil washing treatment reached the same removal efficiency of the flushing process in a shorter time but required a larger amount of the EDDS solution.
NASA Astrophysics Data System (ADS)
Agaoglu, Berken; Scheytt, Traugott; Copty, Nadim K.
2012-10-01
This study examines the mechanistic processes governing multiphase flow of a water-cosolvent-NAPL system in saturated porous media. Laboratory batch and column flushing experiments were conducted to determine the equilibrium properties of pure NAPL and synthetically prepared NAPL mixtures as well as NAPL recovery mechanisms for different water-ethanol contents. The effect of contact time was investigated by considering different steady and intermittent flow velocities. A modified version of multiphase flow simulator (UTCHEM) was used to compare the multiphase model simulations with the column experiment results. The effect of employing different grid geometries (1D, 2D, 3D), heterogeneity and different initial NAPL saturation configurations was also examined in the model. It is shown that the change in velocity affects the mass transfer rate between phases as well as the ultimate NAPL recovery percentage. The experiments with low flow rate flushing of pure NAPL and the 3D UTCHEM simulations gave similar effluent concentrations and NAPL cumulative recoveries. Model simulations over-estimated NAPL recovery for high specific discharges and rate-limited mass transfer, suggesting a constant mass transfer coefficient for the entire flushing experiment may not be valid. When multi-component NAPLs are present, the dissolution rate of individual organic compounds (namely, toluene and benzene) into the ethanol-water flushing solution is found not to correlate with their equilibrium solubility values.
NASA Astrophysics Data System (ADS)
Jakkareddy, Pradeep S.; Balaji, C.
2016-09-01
This paper employs the Bayesian based Metropolis Hasting - Markov Chain Monte Carlo algorithm to solve inverse heat transfer problem of determining the spatially varying heat transfer coefficient from a flat plate with flush mounted discrete heat sources with measured temperatures at the bottom of the plate. The Nusselt number is assumed to be of the form Nu = aReb(x/l)c . To input reasonable values of ’a’ and ‘b’ into the inverse problem, first limited two dimensional conjugate convection simulations were done with Comsol. Based on the guidance from this different values of ‘a’ and ‘b’ are input to a computationally less complex problem of conjugate conduction in the flat plate (15mm thickness) and temperature distributions at the bottom of the plate which is a more convenient location for measuring the temperatures without disturbing the flow were obtained. Since the goal of this work is to demonstrate the eficiacy of the Bayesian approach to accurately retrieve ‘a’ and ‘b’, numerically generated temperatures with known values of ‘a’ and ‘b’ are treated as ‘surrogate’ experimental data. The inverse problem is then solved by repeatedly using the forward solutions together with the MH-MCMC aprroach. To speed up the estimation, the forward model is replaced by an artificial neural network. The mean, maximum-a-posteriori and standard deviation of the estimated parameters ‘a’ and ‘b’ are reported. The robustness of the proposed method is examined, by synthetically adding noise to the temperatures.
FIELD-SCALE EVALUATION OF IN SITU COSOLVENT FLUSHING FOR ENCHANCED AQUIFER REMEDIATION
A comprehensive, field-scale evaluation of in situ cosolvent flushing for enhanced remediation of nonaqueous phase liquid (NAPL)-contaminated aquifers was performed in a hydraulically isolated test cell (about 4.3 m x 3.6 m) constructed at a field site at Hill Air Force Base, Uta...
30 CFR 71.401 - Location of facilities.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Bathing Facilities, Change Rooms, and Sanitary Flush Toilet Facilities at Surface Coal Mines § 71.401 Location of facilities. Bathhouses, change rooms, and sanitary flush toilet facilities shall be in a... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Location of facilities. 71.401 Section 71.401...
30 CFR 71.401 - Location of facilities.
Code of Federal Regulations, 2012 CFR
2012-07-01
... Bathing Facilities, Change Rooms, and Sanitary Flush Toilet Facilities at Surface Coal Mines § 71.401 Location of facilities. Bathhouses, change rooms, and sanitary flush toilet facilities shall be in a... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Location of facilities. 71.401 Section 71.401...
30 CFR 71.401 - Location of facilities.
Code of Federal Regulations, 2014 CFR
2014-07-01
... Bathing Facilities, Change Rooms, and Sanitary Flush Toilet Facilities at Surface Coal Mines § 71.401 Location of facilities. Bathhouses, change rooms, and sanitary flush toilet facilities shall be in a... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Location of facilities. 71.401 Section 71.401...
30 CFR 71.401 - Location of facilities.
Code of Federal Regulations, 2013 CFR
2013-07-01
... Bathing Facilities, Change Rooms, and Sanitary Flush Toilet Facilities at Surface Coal Mines § 71.401 Location of facilities. Bathhouses, change rooms, and sanitary flush toilet facilities shall be in a... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Location of facilities. 71.401 Section 71.401...
The Role of Flushing Dental Waterlines for the Removal of Microbial Contaminants - MCEARD
Objectives. This study was designed to determine the role of flushing dental water lines for the removal of heterotrophic plate count bacteria, Legionella spp., and free-living protozoa. Methods. Forty dental offices were surveyed in the study. An initial sample and a sample tak...
HYDRAULIC CHARACTERISTICS OF SEWER SEDIMENT GATE FLUSHING TANKS: LABORATORY FLUME STUDIES
The objective of this study was to test the performance of gate flushing tanks, simulated in a laboratory flume, to remove sediments from combined sewers and storage tanks. A significant amount of sediment/debris/sludge may accumulate at the bottom of a sewer during dry weather o...
HYDRAULIC CHARACTERISTICS OF SEWER SEDIMENT GATE-FLUSHING TANKS: LABORATORY FLUME STUDIES
The objective of this study was to test the performance of gate-flushing tanks, simulated in a laboratory flume, to remove sediments from combined sewers and storage tanks. A significant amount of sediment/debris/sludge may accumulate at the bottom of a sewer during dry weather o...
NASA Astrophysics Data System (ADS)
Lechleitner, Franziska A.; Breitenbach, Sebastian F. M.; McIntyre, Cameron; Asmerom, Yemane; Prufer, Keith M.; Polyak, Victor; Culleton, Brendan J.; Kennett, Douglas J.; Eglinton, Timothy I.; Baldini, James U. L.
2015-04-01
Speleothem 14C has recently emerged as a potentially powerful proxy for climate reconstruction. Several studies have highlighted the link between karst hydrology and speleothem 14C content, and a number of possible causes for this relationship have been proposed, such as dripwater flow dynamics in the karst and changes in soil organic matter (SOM) turnover time (e.g. Griffiths et al., 2012). Here we present a high resolution 14C record for a stalagmite (YOK-I) from Yok Balum cave in southern Belize, Central America. YOK-I grew continuously over the last 2000 years, and has been dated very precisely with the U-Th method (40 dates, mean uncertainty < 10 years). The excellent chronological control for this stalagmite allows us to calculate 14C activity (a14C) at the time of speleothem deposition (a14Cinit), as well as the dead carbon fraction (DCF), predominantly a measure of the reservoir effect introduced by limestone dissolution in the karst (Genty et al., 2001). Both records show striking similarities to atmospheric a14C (IntCal13) and reconstructions of solar activity and 14C production rate. We infer close coupling between cave environment and atmosphere, with minimal signal dampening, an observation supported by monitoring data (Ridley et al., in press). DCF fluctuates between approximately 10% and 16% over the entire record, with distinctly lower DCF values and higher a14Cinit during a period of reduced rainfall between ca. 700-1100 AD (linked to the Classic Maya Collapse). This behavior is consistent with observations made elsewhere, and suggests that DCF responds to karst hydrological variability, specifically open-closed system transitions. YOK-I a14Cinit typically lags atmospheric values by 10-100 cal years. A shorter lag appears to be linked to periods of drought, suggesting a response of SOM dynamics above the cave to rainfall reduction. Specifically, drought is inferred to lead to reduced bioproductivity and soil carbon turnover, lowering contributions of old recalcitrant carbon to the soil water, and resulting in closer coupling between atmosphere and cave environment. The resolution of the record (0.3-0.7 mm/sample) permits identification of the dominant drivers of stalagmite 14C during different intervals. For example, hydrologic control on 14C appears dominant during the 11th century drought, while in the 16th to 18th century a clear solar influence exists. Solar activity is reflected in YOK-I as lower a14Cinit, reflecting the atmospheric a14C. We apply simple hydrological models to investigate the different factors influencing 14C in YOK-I. We estimate the importance of mean SOM age to signal dampening, and quantify the strength of the solar influence and the global carbon cycle on the record. References: Genty, D., Baker, A., Massault, M., Proctor, C., Gilmour, M., Pons-Branchu, E., Hamelin, B. (2001) Dead carbon in stalagmites: carbonate bedrock paleodissolution vs. ageing of soil organic matter. Implications for 13C variations in speleothems, GCA, 65 Griffiths, M.L., Fohlmeister, J., Drysdale, R.N., Hua, Q., Johnson, K.R., Hellstrom, J.C., Gagan, M.K., Zhao, J.-x. (2012) Hydrological control of the dead carbon fraction in a Holocene tropical speleothem, Quat. Geochron. 14 Ridley, H.E., Baldini, J.U.L., Prufer, K.M., Walczak, I.W., Breitenbach, S.F.M. (in press) High resolution monitoring of a tropical cave system reveals dynamic ventilation and hydrologic resilience to seismic activity, Journal of Cave and Karst Studies
2007-01-01
PTTI) Meeting ( TWSTFT ) is being routinely performed with several European and US stations. On the initiative of NICT, a TWSTFT link was...During the last 2 years, PTB has upgraded its TWSTFT and GPS capabilities in order to achieve better reliability and robustness against system failures...NTP-server, and, briefly, the calibration of the international time links, i.e. the result of the latest calibration of the TWSTFT links to the USNO
A network of multilevel samplers was used to evaluate the spatial patterns in containment extraction during an in situ cosolvent flushing field test. The study was conducted in an isolation test cell installed in a fuel contaminated site at Hill Air Force Base, Utah. Partitioni...
Concealed hinge permits flush mounting of doors and hatches
NASA Technical Reports Server (NTRS)
Holman, E. V.
1966-01-01
Hinge assembly permits flush mounting of doors and hatches of considerable thickness so that the axis of instant rotation, produced by the hinge, lies outside the panel surface and beyond the perimeter adjacent to the hinge. In operation, motion of the assembly is initially parallel, changing to angular after clearing the panel perimeter.
Behavior Interventions in the Restroom: Flushing Away Noise
ERIC Educational Resources Information Center
Pasqua, Jamie L.; Dart, Evan H.; Radley, Keith C.
2016-01-01
This study investigated the effectiveness of Flushing Away Noise, an interdependent group contingency using an iPod equipped with a decibel meter application, for reducing noise in restrooms. Two Head Start classrooms in the Southeastern United States, referred for demonstrating high levels of student noise in the restroom, were included in the…
30 CFR 71.400 - Bathing facilities; change rooms; sanitary flush toilet facilities.
Code of Federal Regulations, 2010 CFR
2010-07-01
... flush toilet facilities. 71.400 Section 71.400 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY HEALTH STANDARDS-SURFACE COAL MINES AND SURFACE... installations and at the surface worksites of such mine. (Note: Sanitary facilities at surface work areas of...
77 FR 76039 - Formations of, Acquisitions by, and Mergers of Bank Holding Companies
Federal Register 2010, 2011, 2012, 2013, 2014
2012-12-26
... York, with and into Flushing Commercial Bank, North New Hyde Park, New York, which will become a New York State-chartered commercial bank and change its name to Flushing Bank. Comments on this proposal... FEDERAL RESERVE SYSTEM Formations of, Acquisitions by, and Mergers of Bank Holding Companies The...
The Total-Pressure Recovery and Drag Characteristics of Several Auxiliary Inlets at Transonic Speeds
NASA Technical Reports Server (NTRS)
Dennard, John S.
1959-01-01
Several flush and scoop-type auxiliary inlets have been tested for a range of Mach numbers from 0.55 to 1.3 to determine their transonic total-pressure recovery and drag characteristics. The inlet dimensions were comparable with the thickness of the boundary layer in which they were tested. Results indicate that flush inlets should be inclined at very shallow angles with respect to the surface for optimum total-pressure recovery and drag characteristics. Deep, narrow inlets have lower drag than wide shallow ones at Mach numbers greater than 0.9 but at lower Mach numbers the wider inlets proved superior. Inlets with a shallow approach ramp, 7 deg, and diverging ramp walls which incorporated boundary-layer bypass had lower drag than any other inlet tested for Mach numbers up to 1.2 and had the highest pressure recovery of all of the flush inlets. The scoop inlets, which operated in a higher velocity flow than the flush inlets, had higher drag coefficients. Several of these auxiliary inlets projected multiple, periodic shock waves into the stream when they were operated at low mass-flow ratios.
Modeling of highway stormwater runoff.
Kim, Lee-Hyung; Kayhanian, Masoud; Zoh, Kyung-Duk; Stenstrom, Michael K
2005-09-15
Highways are stormwater intensive landuses since they are impervious and have high pollutant mass emissions from vehicular activity. Vehicle emissions include different pollutants such as heavy metals, oil and grease, particulates from sources such as fuels, brake pad wear and tire wear, and litter. To understand the magnitude and nature of the stormwater emissions, a 3-year study was conducted to quantify stormwater pollutant concentrations, mass emission rates, and the first flush of pollutants. Eight highway sites were monitored over 3 years for a large suite of pollutants. The monitoring protocol emphasized detecting the first flush and quantifying the event mean concentration. Grab and flow-weighted composite samples, rainfall, and runoff data were collected. A new runoff model with four parameters was developed that to describe the first flush of pollutants for a variety of rainfall and runoff conditions. The model was applied to more than 40 events for 8 pollutants, and the parameters were correlated to storm and site conditions, such as total runoff, antecedent dry days, and runoff coefficient. Improved definitions of first flush criteria are also presented.
NASA Astrophysics Data System (ADS)
Kuang, A. Q.; Brunner, D.; LaBombard, B.; Leccacorvi, R.; Vieira, R.
2018-04-01
An array of flush-mounted and toroidally elongated Langmuir probes (henceforth called rail probes) have been specifically designed for the Alcator C-Mod's vertical target plate divertor and operated over multiple campaigns. The "flush" geometry enables the tungsten electrodes to survive high heat flux conditions in which traditional "proud" tungsten electrodes suffer damage from melting. The toroidally elongated rail-like geometry reduces the influence of sheath expansion, which is an important effect to consider in the design and interpretation of flush-mounted Langmuir probes. The new rail probes successfully operated during C-Mod's FY2015 and FY2016 experimental campaigns with no evidence of damage, despite being regularly subjected to heat flux densities parallel to the magnetic field exceeding ˜1 GW m-2 for short periods of time. A comparison between rail and proud probe data indicates that sheath expansion effects were successfully mitigated by the rail design, extending the use of these Langmuir probes to incident magnetic field line angles as low as 0.5°.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hudson, W.G.
Scapteriscus vicinus is the most important pest of turf and pasture grasses in Florida. This study develops a method of correlating sample results with true population density and provides the first quantitative information on spatial distribution and movement patterns of mole crickets. Three basic techniques for sampling mole crickets were compared: soil flushes, soil corer, and pitfall trapping. No statistical difference was found between the soil corer and soil flushing. Soil flushing was shown to be more sensitive to changes in population density than pitfall trapping. No technique was effective for sampling adults. Regression analysis provided a means of adjustingmore » for the effects of soil moisture and showed soil temperature to be unimportant in predicting efficiency of flush sampling. Cesium-137 was used to label females for subsequent location underground. Comparison of mean distance to nearest neighbor with the distance predicted by a random distribution model showed that the observed distance in the spring was significantly greater than hypothesized (Student's T-test, p < 0.05). Fall adult nearest neighbor distance was not different than predicted by the random distribution hypothesis.« less
Costello, Terry; Watkins, Linda; Straign, Mike; Bean, William; Toth, Linda; Rehg, Jerold
1998-03-01
An important responsibility of animal care programs is to protect research animals from exposure to potentially pathogenic microorganisms. To validate the need for steam sterilization of rodent automatic watering racks, we evaluate the post-sanitation microbial contamination of experimentally inoculated racks and of racks that had been used to house conventional mice. We tested three sanitation protocols: rack-washer sanitation without manifold flush, sanitation that included manifold flush, and sanitation that included manifold flush followed by autoclaving. Rack sanitation, with or without manifold flush, did not reliably eliminate microbial flora from the lixits or manifold drainage water. A total of 43% of all non-autoclaved racks were positive for bacterial contamination after sanitation, and racks that had been used for conventional animal housing were more frequently positive than were experimentally inoculated racks (79% vs 18%). These data indicate that steam sterilization is necessary for eliminating bacteria from automatic watering systems. These observations are particularly important in light of increasing numbers of immune-impaired rodents that may be inadvertently and unnecessarily exposed to microbial pathogens via the automatic watering system.
Reynoso, Mercedes M.N.; Seccacini, Emilia A.; Calcagno, Javier A.; Zerba, Eduardo N.
2017-01-01
DEET and IR3535 are insect repellents present worldwide in commercial products; their efficacy has been mainly evaluated in mosquitoes. This study compares the toxicological effects and the behavioral responses induced by both repellents on the blood-sucking bug Triatoma infestans Klug (Hemiptera: Reduviidae), one of the main vectors of Chagas disease. When applied topically, the Median Lethal Dose (72 h) for DEET was 220.8 µg/insect. Using IR3535, topical application of 500 µg/insect killed no nymphs. The minimum concentration that produced repellency was the same for both compounds: 1,15 µg/cm2. The effect of a mixture DEET:IR3535 1:1 was similar to that of their pure components. Flushing out was assessed in a chamber with a shelter containing groups of ten nymphs. The repellents were aerosolized on the shelter and the number of insects leaving it was recorded for 60 min. During that time, 0.006 g/m3 of the positive control tetramethrin flushed out 76.7% of the nymphs, while 1.76 g/m3 of DEET or IR3535 flushed out 30 and 0%, respectively. The concentrations required for both compounds to produce toxicity or flushing out are too high to have any practical applications. However, they showed a promising repellency. Additional research should be done to evaluate their possible use for personal protection against T. infestans bites. PMID:28533956
Saxton, Ronald E; Yeasmin, Farzana; Alam, Mahbub-Ul; Al-Masud, Abdullah; Dutta, Notan Chandra; Yeasmin, Dalia; Luby, Stephen P; Unicomb, Leanne; Winch, Peter J
2017-09-01
Provision of toilets is necessary but not sufficient to impact health as poor maintenance may impair toilet function and discourage their consistent use. Water in urban slums is both scarce and a prerequisite for toilet maintenance behaviours. We describe the development of behaviour change communications and selection of low-cost water storage hardware to facilitate adequate flushing among users of shared toilets. We conducted nine focus group discussions and six ranking exercises with adult users of shared toilets (50 females, 35 males), then designed and implemented three pilot interventions to facilitate regular flushing and improve hygienic conditions of shared toilets. We conducted follow-up assessments 1 and 2 months post-pilot including nine in-depth interviews and three focus group discussions with adult residents (23 females, 15 males) and three landlords in the pilot communities. Periodic water scarcity was common in the study communities. Residents felt embarrassed to carry water for flushing. Reserving water adjacent to the shared toilet enabled slum residents to flush regularly. Signs depicting rules for toilet use empowered residents and landlords to communicate these expectations for flushing to transient tenants. Residents in the pilot reported improvements in cleanliness and reduced odour inside toilet cubicles. Our pilot demonstrates the potential efficacy of low-cost water storage and behaviour change communications to improve maintenance of and user satisfaction with shared toilets in urban slum settings. © 2017 John Wiley & Sons Ltd.
Production flush of Agaricus blazei on Brazilian casing layers
Colauto, Nelson Barros; da Silveira, Adriano Reis; da Eira, Augusto Ferreira; Linde, Giani Andrea
2011-01-01
This study aimed to verify the biological efficiency and production flushes of Agaricus blazei strains on different casing layers during 90 cultivation days. Four casing layers were used: mixture of subsoil and charcoal (VCS), lime schist (LSC), São Paulo peat (SPP) and Santa Catarina peat (SCP); and two genetically distant A. blazei strains. The fungus was grown in composted substratum and, after total colonization, a pasteurized casing layer was added over the substratum, and fructification was induced. Mushrooms were picked up daily when the basidiocarp veil was stretched, but before the lamella were exposed. The biological efficiency (BE) was determined by the fresh basidiocarp mass divided by the substratum dry mass, expressed in percentage. The production flushes were also determined over time production. The BE and production flushes during 90 days were affected by the strains as well as by the casing layers. The ABL26 and LSC produced the best BE of 60.4%. Although VCS is the most used casing layer in Brazil, it is inferior to other casing layers, for all strains, throughout cultivation time. The strain, not the casing layer, is responsible for eventual variations of the average mushroom mass. In average, circa 50% of the mushroom production occurs around the first month, 30% in the second month, and 20% in third month. The casing layer water management depends on the casing layer type and the strain. Production flush responds better to water reposition, mainly with ABL26, and better porosity to LSC and SCP casing layers. PMID:24031673
Albadrani, Ahmed
2017-01-17
While primary hyperhidrosis can be seen in men, accompanying hot flushes is rarely seen in men. Primary hyperhidrosis is thought to be related to overactivity of the sympathetic nervous system while hot flushes are believed to be related to altered peripheral vascular reactivity and a narrowed thermoregulatory zone. I report the case of a 29-year-old man of Arab origin who presented to a dermatology clinic with a complaint of generalized sweating, with heavier involvement of his inguinal region, axilla, and lower back. His complaint was associated with a transient hot sensation and erythema over the affected areas. He did not respond to topical antiperspirants containing aluminum chloride, topical aluminum chloride, or to botulinum toxin A injected in both inguinal areas. He was then referred to an endocrinology clinic to rule out secondary causes of hyperhidrosis and hot flushes; a primary diagnosis was confirmed. He did not respond to oral glycopyrrolate and additionally was complaining of its anticholinergic side effects. The glycopyrrolate was then replaced with oral clonidine 0.15 mg twice a day. Clonidine was well tolerated without remarkable side effects and he quickly started to feel marked improvement which was maintained for 2 years. I report an atypical presentation of primary hyperhidrosis and hot flushes that was effectively controlled by clonidine without remarkable side effects. Further research on a large number of patients may be required before recommending clonidine in similar conditions.
Defne, Zafer; Ganju, Neil K.
2015-01-01
Estuarine residence time is a major driver of eutrophication and water quality. Barnegat Bay-Little Egg Harbor (BB-LEH), New Jersey, is a lagoonal back-barrier estuary that is subject to anthropogenic pressures including nutrient loading, eutrophication, and subsequent declines in water quality. A combination of hydrodynamic and particle tracking modeling was used to identify the mechanisms controlling flushing, residence time, and spatial variability of particle retention. The models demonstrated a pronounced northward subtidal flow from Little Egg Inlet in the south to Pt. Pleasant Canal in the north due to frictional effects in the inlets, leading to better flushing of the southern half of the estuary and particle retention in the northern estuary. Mean residence time for BB-LEH was 13 days but spatial variability was between ∼0 and 30 days depending on the initial particle location. Mean residence time with tidal forcing alone was 24 days (spatial variability between ∼0 and 50 days); the tides were relatively inefficient in flushing the northern end of the Bay. Scenarios with successive exclusion of physical processes from the models revealed that meteorological and remote offshore forcing were stronger drivers of exchange than riverine inflow. Investigations of water quality and eutrophication should take into account spatial variability in hydrodynamics and residence time in order to better quantify the roles of nutrient loading, production, and flushing.
Comparison of three methods of sampling for endometrial cytology in the mare. Preliminary study.
Defontis, M; Vaillancourt, D; Grand, F X
2011-01-01
This prospective study aims to compare three different sampling techniques for the collection of endometrial cytological specimens in the mare: the guarded culture swab, the uterine cytobrush and the low volume uterine flush. The study population consisted of six healthy Standardbred mares in dioestrus. In each mare an acute endometritis was induced by performing a low- volume uterine flush 6days after ovulation using a sterile isotonic solution (lactated Ringer's solution or ViGro™ Complete Flush Solution). Two days after initiating inflammation, samples were collected from each mare using the three compared techniques: the double guarded cotton swab, the uterine cytobrush and the low volume uterine flush. The cytological evaluation of the samples was based on following criteria: the quality and cellularity of the samples and the number of neutrophils recovered. The uterine cytobrush yielded slides of significantly (p=0.02) better quality than the low volume uterine flush. There was no significant difference between the cytobrush and the double guarded swab technique for the quality. There was no difference between techniques in the number of endometrial cells (p=0.55) and neutrophils recovered (p=0.28). Endometrial cytology is a practical method for the diagnosis of acute endometrial inflammation in the mare. Since no difference in the number of neutrophils was found between the three techniques, the choice of the sampling method should be based on other factors such as practicability, costs and disadvantages of each technique.
Modeling tidal exchange and dispersion in Boston Harbor
Signell, Richard P.; Butman, Bradford
1992-01-01
Tidal dispersion and the horizontal exchange of water between Boston Harbor and the surrounding ocean are examined with a high-resolution (200 m) depth-averaged numerical model. The strongly varying bathymetry and coastline geometry of the harbor generate complex spatial patterns in the modeled tidal currents which are verified by shipboard acoustic Doppler surveys. Lagrangian exchange experiments demonstrate that tidal currents rapidly exchange and mix material near the inlets of the harbor due to asymmetry in the ebb/flood response. This tidal mixing zone extends roughly a tidal excursion from the inlets and plays an important role in the overall flushing of the harbor. Because the tides can only efficiently mix material in this limited region, however, harbor flushing must be considered a two step process: rapid exchange in the tidal mixing zone, followed by flushing of the tidal mixing zone by nontidal residual currents. Estimates of embayment flushing based on tidal calculations alone therefore can significantly overestimate the flushing time that would be expected under typical environmental conditions. Particle-release simulations from point sources also demonstrate that while the tides efficiently exchange material in the vicinity of the inlets, the exact nature of dispersion from point sources is extremely sensitive to the timing and location of the release, and the distribution of particles is streaky and patchlike. This suggests that high-resolution modeling of dispersion from point sources in these regions must be performed explicitly and cannot be parameterized as a plume with Gaussian-spreading in a larger scale flow field.
NASA Astrophysics Data System (ADS)
Agaoglu, B.; Scheytt, T. J.; Copty, N. K.
2011-12-01
This study examines the mechanistic processes governing multiphase flow of a water-cosolvent-NAPL system in saturated porous media. Laboratory batch and column flushing experiments were conducted to determine the equilibrium properties of pure NAPL and synthetically prepared NAPL mixtures as well as NAPL recovery mechanisms for different water-ethanol contents. The effect of contact time was investigated by considering different steady and intermittent flow velocities. A modified version of multiphase flow simulator (UTCHEM) was used to compare the multiphase model simulations with the column experiment results. The effect of employing different grid geometries (1D, 2D, 3D), heterogeneity and different initial NAPL saturation configurations were also examined in the model. It is shown that the change in velocity affects the mass transfer rate between phases as well as the ultimate NAPL recovery percentage. The experiments with slow flow rate flushing of pure NAPL and the 3D UTCHEM simulations gave similar effluent concentrations and NAPL cumulative recoveries. The results were less consistent for fast non-equilibrium flow conditions. The dissolution process from the NAPL mixture into the water-ethanol flushing solutions was found to be more complex than dissolution expressions incorporated in the numerical model. The dissolution rate of individual organic compounds (namely Toluene and Benzene) from a mixture NAPL into the ethanol-water flushing solution is found not to correlate with their equilibrium solubility values.The implications of this controlled experimental and modeling study on field cosolvent remediation applications are discussed.