Sample records for focus magnet options

  1. Magnetically focused liquid drop radiator

    DOEpatents

    Botts, Thomas E.; Powell, James R.; Lenard, Roger

    1986-01-01

    A magnetically focused liquid drop radiator for application in rejecting rgy from a spacecraft, characterized by a magnetizable liquid or slurry disposed in operative relationship within the liquid droplet generator and its fluid delivery system, in combination with magnetic means disposed in operative relationship around a liquid droplet collector of the LDR. The magnetic means are effective to focus streams of droplets directed from the generator toward the collector, thereby to assure that essentially all of the droplets are directed into the collector, even though some of the streams may be misdirected as they leave the generator. The magnetic focusing means is also effective to suppress splashing of liquid when the droplets impinge on the collector.

  2. Magnetically focused liquid drop radiator

    DOEpatents

    Botts, T.E.; Powell, J.R.; Lenard, R.

    1984-12-10

    A magnetically focused liquid drop radiator for application in rejecting energy from a spacecraft, characterized by a magnetizable liquid or slurry disposed in operative relationship within the liquid droplet generator and its fluid delivery system, in combination with magnetic means disposed in operative relationship around a liquid droplet collector of the LDR. The magnetic means are effective to focus streams of droplets directed from the generator toward the collector, thereby to assure that essentially all of the droplets are directed into the collector, even though some of the streams may be misdirected as they leave the generator. The magnetic focusing means is also effective to suppress splashing of liquid when the droplets impinge on the collector.

  3. Inverse photoelectron spectrometer with magnetically focused electron gun

    NASA Technical Reports Server (NTRS)

    Krainsky, Isay L.

    1991-01-01

    An inverse photoelectron spectrometer is described which is based on the design of a magnetically focused low energy electron gun. The magnetic lens extends its field over a relatively large segment of the electron trajectory, which could provide a better focusing effect on a high-current-density low-velocity electron beam, providing the magnetic field in the vicinity of the target is reduced sufficiently to preserve the collinearity of the beam. In order to prove the concept, ray tracing is conducted using the Herrmannsfeldt program for solving electron trajectories in electrostatic and magnetostatic focusing systems. The program allows the calculation of the angles of the electron trajectories with the z axis, at the target location. The results of the ray-tracing procedure conducted for this gun are discussed. Some of the advantages of the magnetic focusing are also discussed.

  4. EDITORIAL: Focus on Dilute Magnetic Semiconductors FOCUS ON DILUTE MAGNETIC SEMICONDUCTORS

    NASA Astrophysics Data System (ADS)

    Chambers, Scott A.; Gallagher, Bryan

    2008-05-01

    This focus issue of New Journal of Physics is devoted to the materials science of dilute magnetic semiconductors (DMS). A DMS is traditionally defined as a diamagnetic semiconductor doped with a few to several atomic per cent of some transition metal with unpaired d electrons. Several kinds of dopant-dopant interactions can in principle couple the dopant spins leading to a ferromagnetic ground state in a dilute magnetic system. These include superexchange, which occurs principally in oxides and only between dopants with one intervening oxygen, and double exchange, in which dopants of different formal charges exchange an electron. In both of these mechanisms, the ferromagnetic alignment is not critically dependent on free carriers in the host semiconductor because exchange occurs via bonds. A third mechanism, discovered in the last few years, involves electrons associated with lattice defects that can apparently couple dopant spins. This mechanism is not well understood. Finally, the most desirable mechanism is carrier-mediated exchange interaction in which the dopant spins are coupled by itinerant electrons or holes in the host semiconductor. This mechanism introduces a fundamental link between magnetic and electrical transport properties and offers the possibility of new spintronic functionalities. In particular electrical gate control of ferromagnetism and the use of spin polarized currents to carry signals for analog and digital applications. The spin light emitting diode is a prototypical device of this kind that has been extensively used to characterize the extent of spin polarization in the active light emitting semiconductor heterostructure. The prototypical carrier mediated ferromagnetic DMS is Mn-doped GaAs. This and closely related narrow gap III-V materials have been very extensively studied. Their properties are generally quite well understood and they have led to important insights into fundamental properties of ferromagnetic systems with strong spin

  5. FOREWORD: Focus on Materials Analysis and Processing in Magnetic Fields Focus on Materials Analysis and Processing in Magnetic Fields

    NASA Astrophysics Data System (ADS)

    Sakka, Yoshio; Hirota, Noriyuki; Horii, Shigeru; Ando, Tsutomu

    2009-03-01

    Recently, interest in the applications of feeble (diamagnetic and paramagnetic) magnetic materials has grown, whereas the popularity of ferromagnetic materials remains steady and high. This trend is due to the progress of superconducting magnet technology, particularly liquid-helium-free superconducting magnets that can generate magnetic fields of 10 T and higher. As the magnetic energy is proportional to the square of the applied magnetic field, the magnetic energy of such 10 T magnets is in excess of 10 000 times that of conventional 0.1 T permanent magnets. Consequently, many interesting phenomena have been observed over the last decade, such as the Moses effect, magnetic levitation and the alignment of feeble magnetic materials. Researchers in this area are widely spread around the world, but their number in Japan is relatively high, which might explain the success of magnetic field science and technology in Japan. Processing in magnetic fields is a rapidly expanding research area with a wide range of promising applications in materials science. The 3rd International Workshop on Materials Analysis and Processing in Magnetic Fields (MAP3), which was held on 14-16 May 2008 at the University of Tokyo, Japan, focused on various topics including magnetic field effects on chemical, physical, biological, electrochemical, thermodynamic and hydrodynamic phenomena; magnetic field effects on the crystal growth and processing of materials; diamagnetic levitation, the magneto-Archimedes effect, spin chemistry, magnetic orientation, control of structure by magnetic fields, magnetic separation and purification, magnetic-field-induced phase transitions, properties of materials in high magnetic fields, the development of NMR and MRI, medical applications of magnetic fields, novel magnetic phenomena, physical property measurement by magnetic fields, and the generation of high magnetic fields. This focus issue compiles 13 key papers selected from the proceedings of MAP3. Other

  6. Magnetic Resonance Imaging-Guided Focused Laser Interstitial Thermal Therapy for Intracranial Lesions: Single-Institution Series

    PubMed Central

    Hawasli, Ammar H.; Bagade, Swapnil; Shimony, Joshua S.; Miller-Thomas, Michelle

    2013-01-01

    BACKGROUND: Surgical treatments for deep-seated intracranial lesions have been limited by morbidities associated with resection. Real-time magnetic resonance imaging–guided focused laser interstitial thermal therapy (LITT) offers a minimally invasive surgical treatment option for such lesions. OBJECTIVE: To review treatments and results of patients treated with LITT for intracranial lesions at Washington University School of Medicine. METHODS: In a review of 17 prospectively recruited LITT patients (34-78 years of age; mean, 59 years), we report demographics, treatment details, postoperative imaging characteristics, and peri- and postoperative clinical courses. RESULTS: Targets included 11 gliomas, 5 brain metastases, and 1 epilepsy focus. Lesions were lobar (n = 8), thalamic/basal ganglia (n = 5), insular (n = 3), and corpus callosum (n = 1). Mean target volume was 11.6 cm3, and LITT produced 93% target ablation. Patients with superficial lesions had shorter intensive care unit stays. Ten patients experienced no perioperative morbidities. Morbidities included transient aphasia, hemiparesis, hyponatremia, deep venous thrombosis, and fatal meningitis. Postoperative magnetic resonance imaging showed blood products within the lesion surrounded by new thin uniform rim of contrast enhancement and diffusion restriction. In conjunction with other therapies, LITT targets often showed stable or reduced local disease. Epilepsy focus LITT produced seizure freedom at 8 months. Preliminary overall median progression-free survival and survival from LITT in tumor patients were 7.6 and 10.9 months, respectively. However, this small cohort has not been followed for a sufficient length of time, necessitating future outcomes studies. CONCLUSION: Early peri- and postoperative clinical data demonstrate that LITT is a safe and viable ablative treatment option for intracranial lesions, and may be considered for select patients. ABBREVIATION: LITT, laser interstitial thermal therapy

  7. Monte Carlo evaluation of magnetically focused proton beams for radiosurgery

    NASA Astrophysics Data System (ADS)

    McAuley, Grant A.; Heczko, Sarah L.; Nguyen, Theodore T.; Slater, James M.; Slater, Jerry D.; Wroe, Andrew J.

    2018-03-01

    The purpose of this project is to investigate the advantages in dose distribution and delivery of proton beams focused by a triplet of quadrupole magnets in the context of potential radiosurgery treatments. Monte Carlo simulations were performed using various configurations of three quadrupole magnets located immediately upstream of a water phantom. Magnet parameters were selected to match what can be commercially manufactured as assemblies of rare-earth permanent magnetic materials. Focused unmodulated proton beams with a range of ~10 cm in water were target matched with passive collimated beams (the current beam delivery method for proton radiosurgery) and properties of transverse dose, depth dose and volumetric dose distributions were compared. Magnetically focused beams delivered beam spots of low eccentricity to Bragg peak depth with full widths at the 90% reference dose contour from ~2.5 to 5 mm. When focused initial beam diameters were larger than matching unfocused beams (10 of 11 cases) the focused beams showed 16%–83% larger peak-to-entrance dose ratios and 1.3 to 3.4-fold increases in dose delivery efficiency. Peak-to-entrance and efficiency benefits tended to increase with larger magnet gradients and larger initial diameter focused beams. Finally, it was observed that focusing tended to shift dose in the water phantom volume from the 80%–20% dose range to below 20% of reference dose, compared to unfocused beams. We conclude that focusing proton beams immediately upstream from tissue entry using permanent magnet assemblies can produce beams with larger peak-to-entrance dose ratios and increased dose delivery efficiencies. Such beams could potentially be used in the clinic to irradiate small-field radiosurgical targets with fewer beams, lower entrance dose and shorter treatment times.

  8. Cost-effectiveness of focused ultrasound, radiosurgery, and DBS for essential tremor.

    PubMed

    Ravikumar, Vinod K; Parker, Jonathon J; Hornbeck, Traci S; Santini, Veronica E; Pauly, Kim Butts; Wintermark, Max; Ghanouni, Pejman; Stein, Sherman C; Halpern, Casey H

    2017-08-01

    Essential tremor remains a very common yet medically refractory condition. A recent phase 3 study demonstrated that magnetic resonance-guided focused ultrasound thalamotomy significantly improved upper limb tremor. The objectives of this study were to assess this novel therapy's cost-effectiveness compared with existing procedural options. Literature searches of magnetic resonance-guided focused ultrasound thalamotomy, DBS, and stereotactic radiosurgery for essential tremor were performed. Pre- and postoperative tremor-related disability scores were collected from 32 studies involving 83 magnetic resonance-guided focused ultrasound thalamotomies, 615 DBSs, and 260 stereotactic radiosurgery cases. Utility, defined as quality of life and derived from percent change in functional disability, was calculated; Medicare reimbursement was employed as a proxy for societal cost. Medicare reimbursement rates are not established for magnetic resonance-guided focused ultrasound thalamotomy for essential tremor; therefore, reimbursements were estimated to be approximately equivalent to stereotactic radiosurgery to assess a cost threshold. A decision analysis model was constructed to examine the most cost-effective option for essential tremor, implementing meta-analytic techniques. Magnetic resonance-guided focused ultrasound thalamotomy resulted in significantly higher utility scores compared with DBS (P < 0.001) or stereotactic radiosurgery (P < 0.001). Projected costs of magnetic resonance-guided focused ultrasound thalamotomy were significantly less than DBS (P < 0.001), but not significantly different from radiosurgery. Magnetic resonance-guided focused ultrasound thalamotomy is cost-effective for tremor compared with DBS and stereotactic radiosurgery and more effective than both. Even if longer follow-up finds changes in effectiveness or costs, focused ultrasound thalamotomy will likely remain competitive with both alternatives. © 2017 International Parkinson and Movement

  9. A novel magnet focusing plate for matrix-assisted laser desorption/ionization analysis of magnetic bead-bound analytes.

    PubMed

    Gode, David; Volmer, Dietrich A

    2013-05-15

    Magnetic beads are often used for serum profiling of peptide and protein biomarkers. In these assays, the bead-bound analytes are eluted from the beads prior to mass spectrometric analysis. This study describes a novel matrix-assisted laser desorption/ionization (MALDI) technique for direct application and focusing of magnetic beads to MALDI plates by means of dedicated micro-magnets as sample spots. Custom-made MALDI plates with magnetic focusing spots were made using small nickel-coated neodymium micro-magnets integrated into a stainless steel plate in a 16 × 24 (384) pattern. For demonstrating the proof-of-concept, commercial C-18 magnetic beads were used for the extraction of a test compound (reserpine) from aqueous solution. Experiments were conducted to study focusing abilities, the required laser energies, the influence of a matrix compound, dispensing techniques, solvent choice and the amount of magnetic beads. Dispensing the magnetic beads onto the micro-magnet sample spots resulted in immediate and strong binding to the magnetic surface. Light microscope images illustrated the homogeneous distribution of beads across the surfaces of the magnets, when the entire sample volume containing the beads was pipetted onto the surface. Subsequent MALDI analysis of the bead-bound analyte demonstrated excellent and reproducible ionization yields. The surface-assisted laser desorption/ionization (SALDI) properties of the strongly light-absorbing γ-Fe2O3-based beads resulted in similar ionization efficiencies to those obtained from experiments with an additional MALDI matrix compound. This feasibility study successfully demonstrated the magnetic focusing abilities for magnetic bead-bound analytes on a novel MALDI plate containing small micro-magnets as sample spots. One of the key advantages of this integrated approach is that no elution steps from magnetic beads were required during analyses compared with conventional bead experiments. Copyright © 2013 John Wiley

  10. Powerful actuation of magnetized microtools by focused magnetic field for particle sorting in a chip.

    PubMed

    Yamanishi, Yoko; Sakuma, Shinya; Onda, Kazuhisa; Arai, Fumihito

    2010-08-01

    This paper describes a novel powerful noncontact actuation of a magnetically driven microtool (MMT), achieved by magnetization of the MMT and focusing of the magnetic field in a microfluidic chip for particle sorting. The following are the highlights of this study: (1) an MMT was successfully fabricated from a mixture of neodymium powder and polydimethylsiloxane; the MMT was magnetized such that it acted as an elastic micromagnet with a magnetic flux density that increased by about 100 times after magnetization, and (2) a pair of sharp magnetic needles was fabricated adjacent to a microchannel in a chip by electroplating, in order to focus the magnetic flux density generated by the electromagnetic coils below the biochip; these needles contribute to miniaturization of an actuation module that would enable the integration of multiple functions in the limited area of a chip. FEM analysis of the magnetic flux density around the MMT showed that the magnetic flux density in the setup with the magnetic needles was around 8 times better than that in the setup without the needles. By magnetization, the drive frequency of the MMT improved by about 10 times--from 18 Hz to 180 Hz. We successfully demonstrated the separation of copolymer beads of a particular size in a chip by image sensing.

  11. Focused-ion-beam induced interfacial intermixing of magnetic bilayers for nanoscale control of magnetic properties.

    PubMed

    Burn, D M; Hase, T P A; Atkinson, D

    2014-06-11

    Modification of the magnetic properties in a thin-film ferromagnetic/non-magnetic bilayer system by low-dose focused ion-beam (FIB) induced intermixing is demonstrated. The highly localized capability of FIB may be used to locally control magnetic behaviour at the nanoscale. The magnetic, electronic and structural properties of NiFe/Au bilayers were investigated as a function of the interfacial structure that was actively modified using focused Ga(+) ion irradiation. Experimental work used MOKE, SQUID, XMCD as well as magnetoresistance measurements to determine the magnetic behavior and grazing incidence x-ray reflectivity to elucidate the interfacial structure. Interfacial intermixing, induced by low-dose irradiation, is shown to lead to complex changes in the magnetic behavior that are associated with monotonic structural evolution of the interface. This behavior may be explained by changes in the local atomic environment within the interface region resulting in a combination of processes including the loss of moment on Ni and Fe, an induced moment on Au and modifications to the spin-orbit coupling between Au and NiFe.

  12. Three-Dimensional Simulations of Electron Beams Focused by Periodic Permanent Magnets

    NASA Technical Reports Server (NTRS)

    Kory, Carol L.

    1999-01-01

    A fully three-dimensional (3D) model of an electron beam focused by a periodic permanent magnet (PPM) stack has been developed. First, the simulation code MAFIA was used to model a PPM stack using the magnetostatic solver. The exact geometry of the magnetic focusing structure was modeled; thus, no approximations were made regarding the off-axis fields. The fields from the static solver were loaded into the 3D particle-in-cell (PIC) solver of MAFIA where fully 3D behavior of the beam was simulated in the magnetic focusing field. The PIC solver computes the time-integration of electromagnetic fields simultaneously with the time integration of the equations of motion of charged particles that move under the influence of those fields. Fields caused by those moving charges are also taken into account; thus, effects like space charge and magnetic forces between particles are fully simulated. The electron beam is simulated by a number of macro-particles. These macro-particles represent a given charge Q amounting to that of several million electrons in order to conserve computational time and memory. Particle motion is unrestricted, so particle trajectories can cross paths and move in three dimensions under the influence of 3D electric and magnetic fields. Correspondingly, there is no limit on the initial current density distribution of the electron beam, nor its density distribution at any time during the simulation. Simulation results including beam current density, percent ripple and percent transmission will be presented, and the effects current, magnetic focusing strength and thermal velocities have on beam behavior will be demonstrated using 3D movies showing the evolution of beam characteristics in time and space. Unlike typical beam optics models, this 3D model allows simulation of asymmetric designs such as non- circularly symmetric electrostatic or magnetic focusing as well as the inclusion of input/output couplers.

  13. Magnetic focusing immunosensor for the detection of Salmonella typhimurium in foods

    NASA Astrophysics Data System (ADS)

    Pivarnik, Philip E.; Cao, He; Letcher, Stephen V.; Pierson, Arthur H.; Rand, Arthur G.

    1999-01-01

    From 1988 through 1992 Salmonellosis accounted for 27% of the total reported foodborne disease outbreaks and 57% of the outbreaks in which the pathogen was identified. The prevalence of Salmonellosis and the new requirements to monitor the organism as a marker in pathogen reduction programs will drive the need for rapid, on-site testing. A compact fiber optic fluorometer using a red diode laser as an excitation source and fiber probes for analyte detection has been constructed and used to measure Salmonella. The organisms were isolated with anti-Salmonella magnetic beads and were labeled with a secondary antibody conjugated to a red fluorescent dye. The response of the system was proportional to the concentration of Salmonella typhimurium from 3.2 X 105 colony forming units (CFU)/ml to 1.6 X 107 CFU/ml. The system was developed to utilize a fiber-optic magnetic focusing problem that attracted the magnetic microspheres to the surface of a sample chamber directly in front of the excitation and emission fibers. The signal obtained from a homogenous suspension of fluorescent magnetic microspheres was 9 to 10 picowatts. After focusing, the signal from the fluorescent labeled magnetic microspheres increased to 200 picowatts, approximately 20 times greater than the homogeneous suspension. The magnetic focusing assay detected 1.59 X 105 colony forming units/ml of Salmonella typhimurium cultured in growth media. The process of magnetic focusing in front of the fibers has the potential to reduce the background fluorescence from unbound secondary antibodies, eliminating several rinsing steps, resulting in a simple rapid assay.

  14. A magnetically focused molecular beam of ortho-water.

    PubMed

    Kravchuk, T; Reznikov, M; Tichonov, P; Avidor, N; Meir, Y; Bekkerman, A; Alexandrowicz, G

    2011-01-21

    Like dihydrogen, water exists as two spin isomers, ortho and para, with the nuclear magnetic moments of the hydrogen atoms either parallel or antiparallel. The ratio of the two spin isomers and their physical properties play an important role in a wide variety of research fields, ranging from astrophysics to nuclear magnetic resonance (NMR). Unlike ortho and para H(2), however, the two water isomers remain challenging to separate, and as a consequence, very little is currently known about their different physical properties. Here, we report the formation of a magnetically focused molecular beam of ortho-water. The beam we formed also had a particular spin projection. Thus, in the presence of holding magnetic fields, the water molecules are hyperpolarized, laying the foundation for ultrasensitive NMR experiments in the future.

  15. Study of Permanent Magnet Focusing for Astronomical Camera Tubes

    NASA Technical Reports Server (NTRS)

    Long, D. C.; Lowrance, J. L.

    1975-01-01

    A design is developed of a permanent magnet assembly (PMA) useful as the magnetic focusing unit for the 35 and 70 mm (diagonal) format SEC tubes. Detailed PMA designs for both tubes are given, and all data on their magnetic configuration, size, weight, and structure of magnetic shields adequate to screen the camera tube from the earth's magnetic field are presented. A digital computer is used for the PMA design simulations, and the expected operational performance of the PMA is ascertained through the calculation of a series of photoelectron trajectories. A large volume where the magnetic field uniformity is greater than 0.5% appears obtainable, and the point spread function (PSF) and modulation transfer function(MTF) indicate nearly ideal performance. The MTF at 20 cycles per mm exceeds 90%. The weight and volume appear tractable for the large space telescope and ground based application.

  16. Magnetic compound refractive lens for focusing and polarizing cold neutron beams.

    PubMed

    Littrell, K C; te Velthuis, S G E; Felcher, G P; Park, S; Kirby, B J; Fitzsimmons, M R

    2007-03-01

    Biconcave cylindrical lenses are used to focus beams of x rays or neutrons using the refractive properties of matter. In the case of neutrons, the refractive properties of magnetic induction can similarly focus and simultaneously polarize the neutron beam without the concomitant attenuation of matter. This concept of a magnetic refractive lens was tested using a compound lens consisting of 99 pairs of cylindrical permanent magnets. The assembly successfully focused the intensity of a white beam of cold neutrons of one spin state at the detector, while defocusing the other. This experiment confirmed that a lens of this nature may boost the intensity locally by almost an order of magnitude and create a polarized beam. An estimate of the performance of a more practically dimensioned device suitable for incorporation in reflectometers and slit-geometry small angle scattering instruments is given.

  17. Research Update: Focused ion beam direct writing of magnetic patterns with controlled structural and magnetic properties

    NASA Astrophysics Data System (ADS)

    Urbánek, Michal; Flajšman, Lukáš; Křižáková, Viola; Gloss, Jonáš; Horký, Michal; Schmid, Michael; Varga, Peter

    2018-06-01

    Focused ion beam irradiation of metastable Fe78Ni22 thin films grown on Cu(100) substrates is used to create ferromagnetic, body-centered cubic patterns embedded into paramagnetic, face-centered-cubic surrounding. The structural and magnetic phase transformation can be controlled by varying parameters of the transforming gallium ion beam. The focused ion beam parameters such as the ion dose, number of scans, and scanning direction can be used not only to control a degree of transformation but also to change the otherwise four-fold in-plane magnetic anisotropy into the uniaxial anisotropy along a specific crystallographic direction. This change is associated with a preferred growth of specific crystallographic domains. The possibility to create magnetic patterns with continuous magnetization transitions and at the same time to create patterns with periodical changes in magnetic anisotropy makes this system an ideal candidate for rapid prototyping of a large variety of nanostructured samples. Namely, spin-wave waveguides and magnonic crystals can be easily combined into complex devices in a single fabrication step.

  18. Focusing of intense and divergent ion beams in a magnetic mass analyzer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jianlin, Ke; Changgeng, Zhou; Rui, Qiu

    2014-07-15

    A magnetic mass analyzer is used to determine the beam composition of a vacuum arc ion source. In the analyzer, we used the concentric multi-ring electrodes to focus the intense and divergent ion beams. We describe the principle, design, and the test results of the focusing device. The diameter of the beam profile is less than 20 mm when the accelerating voltage is 30 kV and the focusing voltage is about 2.0 kV. The focusing device has been successfully used in the magnetic mass analyzer to separate Ti{sup +}, Ti{sup 2+}, and Ti{sup 3+}.

  19. Performance of high power S-band klystrons focused with permanent magnet

    NASA Astrophysics Data System (ADS)

    Fukuda, S.; Shidara, T.; Saito, Y.; Hanaki, H.; Nakao, K.; Homma, H.; Anami, S.; Tanaka, J.

    1987-02-01

    Performance of high power S-band klystrons focused with permanent magnet is presented. The axial magnetic field distribution and the transverse magnetic field play an important role in the tube performance. Effects of the reversal field in the collector and the cathode-anode region are discussed precisely. It is also shown that the tube efficiency is strongly affected with the residual transverse magnetic field. The allowable transverse field is less than 0.3 percent of the longitudinal field in the entire RF interaction region of the klystron.

  20. Superstrong Adjustable Permanent Magnet for a Linear Collider Final Focus

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mihara, T.

    A superstrong permanent magnet quadrupole (PMQ) is one of the candidates for the final focus lens for the linear collider because of its compactness and low power consumption. The first fabricated prototype of our PMQ achieved a 300T/m superstrong field gradient with a 100mm overall magnet radius and a 7mm bore radius, but a drawback is its fixed strength. Therefore, a second prototype of PMQ, whose strength is adjustable, was fabricated. Its strength adjustability is based on the ''double ring structure'', rotating subdivided magnet slices separately. This second prototype is being tested. Some of the early results are presented.

  1. Magnetic resonance guided high-intensity focused ultrasound ablation of musculoskeletal tumors

    PubMed Central

    Avedian, Raffi S.; Gold, Garry; Ghanouni, Pejman; Pauly, Kim Butts

    2015-01-01

    This article reviews the fundamental principles and clinical experimental uses of magnetic resonance guided high-intensity focused ultrasound (MRgHIFU) ablation of musculoskeletal tumors. MRgHIFU is a noninvasive treatment modality that takes advantage of the ability of magnetic resonance to measure tissue temperature and uses this technology to guide high-intensity focused ultrasound waves to a specific focus within the human body that results in heat generation and complete thermal necrosis of the targeted tissue. Adjacent normal tissues are spared because of the accurate delivery of thermal energy, as well as, local blood perfusion that provides a cooling effect. MRgHIFU is approved by the Food and Drug Administration for the treatment of uterine fibroids and is used on an experimental basis to treat breast, prostate, liver, bone, and brain tumors. PMID:26120376

  2. Electron acceleration by a focused laser pulse in a static magnetic field

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Huang Shihua; Wu Fengmin; Zhao Xianghao

    2007-12-15

    The model given by K. P. Singh [Phys. Rev. E 69, 056410 (2004)] for vacuum laser acceleration in a static magnetic field is revisited by including the effects of diffraction and the longitudinal electric field of a focused laser beam. Compared with a similar model without a static magnetic field, a simulation shows that electrons can gain much more net energy in this model even using the fifth-order corrected equations for the field of a focused laser beam. The acceleration mechanism and the acceleration efficiency are also investigated.

  3. Confinement effect of cylindrical-separatrix-type magnetic field on the plume of magnetic focusing type Hall thruster

    NASA Astrophysics Data System (ADS)

    Yu, Daren; Meng, Tianhang; Ning, Zhongxi; Liu, Hui

    2017-04-01

    A magnetic focusing type Hall thruster was designed with a cylindrical magnetic seperatrix. During the process of a hollow cathode crossing the separatrix, the variance of plume parameter distribution was monitored. Results show that the ion flux on the large spatial angle is significantly lower when the hollow cathode is located in the inner magnetic field. This convergence effect is preserved even in a distant area. A mechanism was proposed for plume divergence from the perspective of cathode-to-plume potential difference, through which the confinement effect of cylindrical-separatrix-type magnetic field on thruster plume was confirmed and proposed as a means of plume protection for plasma propulsion devices.

  4. Efficacy of Magnetic Resonance-guided Focused Ultrasound Surgery for Bone Metastases Pain Palliation

    NASA Astrophysics Data System (ADS)

    Kawasaki, Motohiro; Nanba, Hirofumi; Kato, Tomonari; Tani, Toshikazu; Ushida, Takahiro

    2011-09-01

    Magnetic resonance-guided focused ultrasound surgery (MRgFUS) is a novel treatment method that achieves non-invasive thermal ablation by focusing many ultrasound waves on a target tissue with real-time monitoring of the location and temperature of the target during the procedure. We investigated the palliative effect on pain and safety of MRgFUS in painful bone metastases. Six patients (mean age, 65.8 years) who met eligibility criteria for the clinical study approved by our Institutional Ethics Committee based on the cooperative protocol were treated with MRgFUS. Targeted sites included the sacrum (n = 1), ilium (n = 2), scapula (n = 2), and femur (n = 1). The mean follow-up period was 9.2 months. All procedures were performed as a single-session treatment using the treatment system that is integrated into the patient table of a magnetic resonance image (MRI) scanner. Endpoints were change in the intensity of pain due to bone metastases from before to after the treatment, as measured on a numerical rating scale, pain interference with daily activities as determined by the Brief pain inventory (BPI), change in images, and safety. Pain relief was obtained in all patients early after treatment, with a reduction in the mean pain score from 6.0±1.3 at baseline to 1.2±1.0 at the end of follow-up as well as in pain interference with daily activities. The mean time required for a single-session treatment was 83.7±37.0 min, with a mean number of sonications required of 13.3±3.7 and mean energy applied of 846.4±273.5 J. No significant growth of tumors was observed, nor were there treatment-related adverse events. These results suggest that MRgFUS has a non-invasive palliative effect on the localized pain in patients with bone metastasis. MRgFUS could become an option in treatment strategies for painful bone metastases in the future.

  5. Magnetic Resonance-Guided High-Intensity Focused Ultrasound Ablation of Osteoid Osteoma: A Case Series Report.

    PubMed

    Rovella, Marcello S; Martins, Guilherme L P; Cavalcanti, Conrado F A; Bor-Seng-Shu, Edson; Camargo, Olavo P; Cerri, Giovanni G; Menezes, Marcos R

    2016-04-01

    Osteoid osteoma is painful benign tumor. The aim of this study was to report our initial experience using magnetic resonance-guided focused ultrasound to treat osteoid osteomas. This retrospective single-center study included four patients treated with magnetic resonance-guided focused ultrasound. They presented with severe pain with reduced quality of life and a poor response to clinical treatment. The pre- and post-treatment evaluation comprised computed tomography and magnetic resonance imaging and focused on quality of life and the impact of pain on daily activities. After treatment, three patients had complete pain resolution with no recurrence. One patient had a recurrence of symptoms after 2 wk and underwent a new successful treatment with increased energy levels. On average, 13 sonications were administered (8-18 sonications/treatment) with an average energy of 2,003 J (range: 1,063-3,522 J). Magnetic resonance-guided focused ultrasound appears to be a feasible, tolerable and effective treatment in selected patients with osteoid osteomas. Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  6. Design of high-perveance confined-flow guns for periodic-permanent-magnet-focused tubes

    NASA Technical Reports Server (NTRS)

    Stankiewicz, N.

    1979-01-01

    An approach to the design of high perveance, low compression guns is described in which confinement is used to stabilize the beam for subsequent periodic-permanent-magnet focusing. The computed results for two cases are presented. A magnetic boundary value problem was solved for the scalar potential from which the axial magnetic field was computed. A solution was found by iterating between Poisson's equation and the electron trajectory calculations. Magnetic field values were varied in magnitude until a laminar beam with minimum scalloping was produced.

  7. Effects of Transferring to STEM-Focused Charter and Magnet Schools on Student Achievement

    ERIC Educational Resources Information Center

    Judson, Eugene

    2014-01-01

    There have been strong calls to action in recent years to promote both school choice and the learning of science, technology, engineering, and mathematics (STEM). This has led to the burgeoning development of STEM-focused schools. Nine STEM-focused charter and 2 STEM-focused magnet schools that serve elementary-aged students were examined to…

  8. SU-F-T-211: Evaluation of a Dual Focusing Magnet System for the Treatment of Small Proton Targets

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nguyen, TT; McAuley, GA; Heczko, S

    Purpose: To investigate magnetic focusing for small volume proton targets using a doublet combination of quadrupole rare earth permanent magnet Halbach cylinder assemblies Methods: Monte Carlo computer simulations were performed using the Geant4 toolkit to compare dose depositions of proton beams transported through two focusing magnets or in their absence. Proton beams with energies of 127 MeV and initial diameters of 5, 8 and 10 mm were delivered through two identical focusing magnets similar to those currently in experimental use at Loma Linda University Medical Center. Analogous experiments used optimized configurations based on the simulation results. Dose was measured bymore » a diode detector and Gafchromic EBT3 film and compared to simulation data. Based on results from the experimental data, an additional set of simulations was performed with an initial beam diameter of 18 mm and a two differing length magnets (40mm & 68mm). Results: Experimental data matched well with Monte Carlo simulations. However, under conditions necessary to produce circular beam spots at target depth, magnetically focused beams using two identical 40 mm length magnets did not meet all of our performance criteria of circular beam spots, improved peak to entrance (P/E) dose ratios and dose delivery efficiencies. The simulations using the longer 68 mm 2nd magnet yielded better results with 34% better P/E dose ratio and 20–50% better dose delivery efficiencies when compared to unfocused 10 mm beams. Conclusion: While magnetic focusing using two magnets with identical focusing power did not yield desired results, ongoing Monte Carlo simulations suggest that increasing the length of the 2nd magnet to 68 mm could improve P/E dose ratios and dose efficiencies. Future work includes additional experimental validation of the longer 2nd magnet setup as well as experiments with triplet magnet systems. This project was sponsored with funding from the Department of Defense (DOD# W81XWH-BAA-10

  9. Theoretical predictions for spatially-focused heating of magnetic nanoparticles guided by magnetic particle imaging field gradients

    NASA Astrophysics Data System (ADS)

    Dhavalikar, Rohan; Rinaldi, Carlos

    2016-12-01

    Magnetic nanoparticles in alternating magnetic fields (AMFs) transfer some of the field's energy to their surroundings in the form of heat, a property that has attracted significant attention for use in cancer treatment through hyperthermia and in developing magnetic drug carriers that can be actuated to release their cargo externally using magnetic fields. To date, most work in this field has focused on the use of AMFs that actuate heat release by nanoparticles over large regions, without the ability to select specific nanoparticle-loaded regions for heating while leaving other nanoparticle-loaded regions unaffected. In parallel, magnetic particle imaging (MPI) has emerged as a promising approach to image the distribution of magnetic nanoparticle tracers in vivo, with sub-millimeter spatial resolution. The underlying principle in MPI is the application of a selection magnetic field gradient, which defines a small region of low bias field, superimposed with an AMF (of lower frequency and amplitude than those normally used to actuate heating by the nanoparticles) to obtain a signal which is proportional to the concentration of particles in the region of low bias field. Here we extend previous models for estimating the energy dissipation rates of magnetic nanoparticles in uniform AMFs to provide theoretical predictions of how the selection magnetic field gradient used in MPI can be used to selectively actuate heating by magnetic nanoparticles in the low bias field region of the selection magnetic field gradient. Theoretical predictions are given for the spatial decay in energy dissipation rate under magnetic field gradients representative of those that can be achieved with current MPI technology. These results underscore the potential of combining MPI and higher amplitude/frequency actuation AMFs to achieve selective magnetic fluid hyperthermia (MFH) guided by MPI.

  10. Focused tight dressing does not prevent cochlear implant magnet migration under 1.5 Tesla MRI.

    PubMed

    Cuda, D; Murri, A; Succo, G

    2013-04-01

    We report a retrospective case of inner magnet migration, which occurred after 1.5 Tesla MRI scanning in an adult recipient of a bilateral cochlear implant (CI) despite a focused head dressing. The patient, bilaterally implanted with Nucleus 5 CIs (Cochlear LTD, Sydney, Australia), underwent a 1.5 Tesla cholangio-MRI scan for biliary duct pathology. In subsequent days, a focal skin alteration appeared over the left inner coil. Plain skull radiographs showed partial magnet migration on the left side. Surgical exploration confirmed magnet twisting; the magnet was effectively repositioned. Left CI performance was restored to pre-migration level. The wound healed without complications. Thus, focused dressing does not prevent magnet migration in CI recipients undergoing 1.5 Tesla MRI. All patients should be counselled on this potential complication. A minor surgical procedure is required to reposition the magnet. Nevertheless, timely diagnosis is necessary to prevent skin breakdown and subsequent device contamination. Plain skull radiograph is very effective in identifying magnet twisting; it should be performed systematically after MRI or minimally on all suspected cases.

  11. An investigation into the torque density capabilities of flux-focusing magnetic gearboxes

    NASA Astrophysics Data System (ADS)

    Uppalapati, Krishna Kiran

    Wind and many rotary based ocean energy conversion devices rely on a mechanical gearbox to increase their speed so as to match the requirements of the electromagnetic generator. However, mechanical gearboxes have a number of disadvantages such as the need for gear lubrication, no overload protection and the creation of acoustic noise. Frequently direct-drive generators are employed to overcome these issues, wherein the gearbox is removed and the shaft of the turbine is directly connected to the synchronous generator, either with an electrically excited or permanent magnet rotor. If the input speed to the generator is very low the torque must be very high in order to generate the necessary power. However, as the electrical loading of a synchronous generator is thermally limited, the size of the generator will become excessively large at high power levels. An alternative to these technologies is to consider replacing the mechanical gearbox with a magnetic gear. A magnetic gear can create speed change without any physical contact. It has inherent overload protection, and its non-contact operation offers the potential for high reliability. Despite significant progress, existing magnetic gear designs do not achieve torque densities that are competitive with mechanical gearboxes. This research has focused on designing a coaxial magnetic gear that can operate at a volumetric torque density that is comparable to a mechanical gearbox. A flux-focusing rotor topology also called spoke-type rotor magnet arrangement was adopted to improve the air-gap magnetic flux density which in turn improves the torque transferred between the rotors. Finite element analysis was utilized to conduct a parameter sweep analysis of the different geometric parameters of the magnetic gear. A sub-scale magnetic gear with a diameter of 110 mm and a scaled-up magnetic gear with a diameter of 228 mm was designed, constructed and experimentally evaluated. The torque and torque density of sub

  12. Replacement and Original Magnet Engineering Options (ROMEOs): A European Seventh Framework Project to Develop Advanced Permanent Magnets Without, or with Reduced Use of, Critical Raw Materials

    NASA Astrophysics Data System (ADS)

    Mcguiness, P.; Akdogan, O.; Asali, A.; Bance, S.; Bittner, F.; Coey, J. M. D.; Dempsey, N. M.; Fidler, J.; Givord, D.; Gutfleisch, O.; Katter, M.; Le Roy, D.; Sanvito, S.; Schrefl, T.; Schultz, L.; Schwöbl, C.; Soderžnik, M.; Šturm, S.; Tozman, P.; Üstüner, K.; Venkatesan, M.; Woodcock, T. G.; Žagar, K.; Kobe, S.

    2015-06-01

    The rare-earth crisis, which peaked in the summer of 2011 with the prices of both light and heavy rare earths soaring to unprecedented levels, brought about the widespread realization that the long-term availability and price stability of rare earths could not be guaranteed. This triggered a rapid response from manufacturers involved in rare earths, as well as governments and national and international funding agencies. In the case of rare-earth-containing permanent magnets, three possibilities were given quick and serious consideration: (I) increased recycling of devices containing rare earths; (II) the search for new, mineable, rare-earth resources beyond those in China; and (III) the development of high-energy-product permanent magnets with little or no rare-earth content used in their manufacture. The Replacement and Original Magnet Engineering Options (ROMEO) project addresses the latter challenge using a two-pronged approach. With its basis on work packages that include materials modeling and advanced characterization, the ROMEO project is an attempt to develop a new class of novel permanent magnets that are free of rare earths. Furthermore, the project aims to minimize rare-earth content, particularly heavy-rare-earth (HRE) content, as much as possible in Nd-Fe-B-type magnets. Success has been achieved on both fronts. In terms of new, rare-earth-free magnets, a Heusler alloy database of 236,945 compounds has been narrowed down to approximately 20 new compounds. Of these compounds, Co2MnTi is expected to be a ferromagnet with a high Curie temperature and a high magnetic moment. Regarding the reduction in the amount of rare earths, and more specifically HREs, major progress is seen in electrophoretic deposition as a method for accurately positioning the HRE on the surface prior to its diffusion into the microstructure. This locally increases the coercivity of the rather small Nd-Fe-B-type magnet, thereby substantially reducing the dependence on the HREs Dy and

  13. Focal point determination in magnetic resonance-guided focused ultrasound using tracking coils.

    PubMed

    Svedin, Bryant T; Beck, Michael J; Hadley, J Rock; Merrill, Robb; de Bever, Joshua T; Bolster, Bradley D; Payne, Allison; Parker, Dennis L

    2017-06-01

    To develop a method for rapid prediction of the geometric focus location in MR coordinates of a focused ultrasound (US) transducer with arbitrary position and orientation without sonicating. Three small tracker coil circuits were designed, constructed, attached to the transducer housing of a breast-specific MR-guided focused US (MRgFUS) system with 5 degrees of freedom, and connected to receiver channel inputs of an MRI scanner. A one-dimensional sequence applied in three orthogonal directions determined the position of each tracker, which was then corrected for gradient nonlinearity. In a calibration step, low-level heating located the US focus in one transducer position orientation where the tracker positions were also known. Subsequent US focus locations were determined from the isometric transformation of the trackers. The accuracy of this method was verified by comparing the tracking coil predictions to thermal center of mass calculated using MR thermometry data acquired at 16 different transducer positions for MRgFUS sonications in a homogeneous gelatin phantom. The tracker coil predicted focus was an average distance of 2.1 ± 1.1 mm from the thermal center of mass. The one-dimensional locator sequence and prediction calculations took less than 1 s to perform. This technique accurately predicts the geometric focus for a transducer with arbitrary position and orientation without sonicating. Magn Reson Med 77:2424-2430, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  14. Periodic permanent magnet focused klystron

    DOEpatents

    Ferguson, Patrick; Read, Michael; Ives, R Lawrence

    2015-04-21

    A periodic permanent magnet (PPM) klystron has beam transport structures and RF cavity structures, each of which has permanent magnets placed substantially equidistant from a beam tunnel formed about the central axis, and which are also outside the extent of a cooling chamber. The RF cavity sections also have permanent magnets which are placed substantially equidistant from the beam tunnel, but which include an RF cavity coupling to the beam tunnel for enhancement of RF carried by an electron beam in the beam tunnel.

  15. The performance of magnetic lens for focusing VCN-SANS

    NASA Astrophysics Data System (ADS)

    Nop Collaboration; Yamada, M.; Iwashita, Y.; Kanaya, T.; Ichikawa, M.; Tongu, H.; Kennedy, S. J.; Shimizu, H. M.; Mishima, K.; Yamada, N. L.; Hirota, K.; Carpenter, J. M.; Lal, J.; Andersen, K.; Geltenbort, P.; Guerard, B.; Manzin, G.; Hino, M.; Kitaguchi, M.; Bleuel, M.; NOP Collaboration

    2011-04-01

    We have developed a prototype rotating-permanent magnet sextupole lens (named rot-PMSx) for more efficient experiments with neutron beams in time of flight (ToF) mode. This lens can modulate the focusing strength over range 1.5×104T/m2⩽g‧⩽5.9×104T/m2. Synchronization between the modulation and the beam pulse produces a focused beam without significant chromatic aberration. We anticipate that this lens could be utilized in focusing small angle neutron scattering (SANS) instruments for novel approach to high resolution SANS.We carried out experiments testing the principle of this lens at the very cold neutron (VCN) beamline (PF2) at Institut Laue-Langevin (ILL), France. The focused beam image size at the detector was kept constant at the same beam size as the source (≈3mm) over a wavelength range of 30Å⩽λ⩽48Å in focal length of ≈1.14m. The flux gain was about 12 relative to a beam without focusing, and the depth of focus was quite large. These results show the good performance of this lens and the system. Thereupon we have demonstrated the performance of this test bed for high resolution focusing of VCN-SANS for a well-studied softmatter sample; a deuterium oxide solution of Pluronic F127, an (PEO)100(PPO)65(PEO)100 tri-block copolymer in deuterium oxide. The results of the focusing experiment and the focusing VCN-SANS are presented.

  16. Results of focus group assessments of transportation financing options.

    DOT National Transportation Integrated Search

    2013-01-01

    The Wisconsin Commission on Transportation Finance and Policy was created in the 2011-2013 biennial state budget to : identify and evaluate transportation finance options to address needs into the future. As part of its scope, the Commission : needed...

  17. Noninvasive transcranial focused ultrasonic-magnetic stimulation for modulating brain oscillatory activity

    NASA Astrophysics Data System (ADS)

    Yuan, Yi; Chen, Yudong; Li, Xiaoli

    2016-02-01

    A novel technique, transcranial focused ultrasonic-magnetic stimulation (tFUMS), has been developed for noninvasive brain modulation in vivo. tFUMS has a higher spatial resolution (<2 mm) and a higher penetration depth than other noninvasive neuromodulation methods. The in vivo animal experimental results show that tFUMS can not only increase the power of local field potentials and the firing rate of the neurons, but also enhance the effect of transcranial focused ultrasound stimulation on the neuromodulation. The results demonstrate that tFUMS can modulate brain oscillatory activities by stimulating brain tissues.

  18. Distributed Energy Implementation Options

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shah, Chandralata N

    2017-09-13

    This presentation covers the options for implementing distributed energy projects. It distinguishes between options available for distributed energy that is government owned versus privately owned, with a focus on the privately owned options including Energy Savings Performance Contract Energy Sales Agreements (ESPC ESAs). The presentation covers the new ESPC ESA Toolkit and other Federal Energy Management Program resources.

  19. Enhanced collective focusing of intense neutralized ion beam pulses in the presence of weak solenoidal magnetic fields

    DOE PAGES

    Dorf, Mikhail A.; Davidson, Ronald C.; Kaganovich, Igor D.; ...

    2012-05-31

    In this study, the design of ion drivers for warm dense matter and high energy density physics applications and heavy ion fusion involves transverse focusing and longitudinal compression of intense ion beams to a small spot size on the target. To facilitate the process, the compression occurs in a long drift section filled with a dense background plasma, which neutralizes the intense beam self-fields. Typically, the ion bunch charge is better neutralized than its current, and as a result a net self-pinching (magnetic) force is produced. The self-pinching effect is of particular practical importance, and is used in various ionmore » driver designs in order to control the transverse beam envelope. In the present work we demonstrate that this radial self-focusing force can be significantly enhanced if a weak (B~100 G) solenoidal magnetic field is applied inside the neutralized drift section, thus allowing for substantially improved transport. It is shown that in contrast to magnetic self-pinching, the enhanced collective self-focusing has a radial electric field component and occurs as a result of the overcompensation of the beam charge by plasmaelectrons, whereas the beam current becomes well-neutralized. As the beam leaves the neutralizing drift section, additional transverse focusing can be applied. For instance, in the neutralized drift compression experiments (NDCX) a strong (several Tesla) final focus solenoid is used for this purpose. In the present analysis we propose that the tight final focus in the NDCX experiments may possibly be achieved by using a much weaker (few hundred Gauss) magnetic lens, provided the ion beam carries an equal amount of co-moving neutralizing electrons from the preceding drift section into the lens. In this case the enhanced focusing is provided by the collective electrondynamics strongly affected by a weak applied magnetic field.« less

  20. Neurosurgical Applications of High-Intensity Focused Ultrasound with Magnetic Resonance Thermometry.

    PubMed

    Colen, Rivka R; Sahnoune, Iman; Weinberg, Jeffrey S

    2017-10-01

    Magnetic resonance guided focused ultrasound surgery (MRgFUS) has potential noninvasive effects on targeted tissue. MRgFUS integrates MRI and focused ultrasound surgery (FUS) into a single platform. MRI enables visualization of the target tissue and monitors ultrasound-induced effects in near real-time during FUS treatment. MRgFUS may serve as an adjunct or replace invasive surgery and radiotherapy for specific conditions. Its thermal effects ablate tumors in locations involved in movement disorders and essential tremors. Its nonthermal effects increase blood-brain barrier permeability to enhance delivery of therapeutics and other molecules. Copyright © 2017 Elsevier Inc. All rights reserved.

  1. A historical overview of magnetic resonance imaging, focusing on technological innovations.

    PubMed

    Ai, Tao; Morelli, John N; Hu, Xuemei; Hao, Dapeng; Goerner, Frank L; Ager, Bryan; Runge, Val M

    2012-12-01

    Magnetic resonance imaging (MRI) has now been used clinically for more than 30 years. Today, MRI serves as the primary diagnostic modality for many clinical problems. In this article, historical developments in the field of MRI will be discussed with a focus on technological innovations. Topics include the initial discoveries in nuclear magnetic resonance that allowed for the advent of MRI as well as the development of whole-body, high field strength, and open MRI systems. Dedicated imaging coils, basic pulse sequences, contrast-enhanced, and functional imaging techniques will also be discussed in a historical context. This article describes important technological innovations in the field of MRI, together with their clinical applicability today, providing critical insights into future developments.

  2. Periodic magnetic field as a polarized and focusing thermal neutron spectrometer and monochromator.

    PubMed

    Cremer, J T; Williams, D L; Fuller, M J; Gary, C K; Piestrup, M A; Pantell, R H; Feinstein, J; Flocchini, R G; Boussoufi, M; Egbert, H P; Kloh, M D; Walker, R B

    2010-01-01

    A novel periodic magnetic field (PMF) optic is shown to act as a prism, lens, and polarizer for neutrons and particles with a magnetic dipole moment. The PMF has a two-dimensional field in the axial direction of neutron propagation. The PMF alternating magnetic field polarity provides strong gradients that cause separation of neutrons by wavelength axially and by spin state transversely. The spin-up neutrons exit the PMF with their magnetic spins aligned parallel to the PMF magnetic field, and are deflected upward and line focus at a fixed vertical height, proportional to the PMF period, at a downstream focal distance that increases with neutron energy. The PMF has no attenuation by absorption or scatter, as with material prisms or crystal monochromators. Embodiments of the PMF include neutron spectrometer or monochromator, and applications include neutron small angle scattering, crystallography, residual stress analysis, cross section measurements, and reflectometry. Presented are theory, experimental results, computer simulation, applications of the PMF, and comparison of its performance to Stern-Gerlach gradient devices and compound material and magnetic refractive prisms.

  3. Periodic magnetic field as a polarized and focusing thermal neutron spectrometer and monochromator

    PubMed Central

    Cremer, J. T.; Williams, D. L.; Fuller, M. J.; Gary, C. K.; Piestrup, M. A.; Pantell, R. H.; Feinstein, J.; Flocchini, R. G.; Boussoufi, M.; Egbert, H. P.; Kloh, M. D.; Walker, R. B.

    2010-01-01

    A novel periodic magnetic field (PMF) optic is shown to act as a prism, lens, and polarizer for neutrons and particles with a magnetic dipole moment. The PMF has a two-dimensional field in the axial direction of neutron propagation. The PMF alternating magnetic field polarity provides strong gradients that cause separation of neutrons by wavelength axially and by spin state transversely. The spin-up neutrons exit the PMF with their magnetic spins aligned parallel to the PMF magnetic field, and are deflected upward and line focus at a fixed vertical height, proportional to the PMF period, at a downstream focal distance that increases with neutron energy. The PMF has no attenuation by absorption or scatter, as with material prisms or crystal monochromators. Embodiments of the PMF include neutron spectrometer or monochromator, and applications include neutron small angle scattering, crystallography, residual stress analysis, cross section measurements, and reflectometry. Presented are theory, experimental results, computer simulation, applications of the PMF, and comparison of its performance to Stern–Gerlach gradient devices and compound material and magnetic refractive prisms. PMID:20113108

  4. Magnetic suspension options for spacecraft inertia-wheel applications

    NASA Technical Reports Server (NTRS)

    Downer, J. R.

    1984-01-01

    Design criteria for spacecraft inertia-wheel suspensions are listed. The advantages of magnetic suspensions over other suspension types for spacecraft inertia-wheel applications are cited along with the functions performed by magnetic suspension. The common designs for magnetic suspensions are enumerated. Materials selection of permanent magnets and core materials is considered.

  5. Noninvasive thermal ablation of hepatocellular carcinoma by using magnetic resonance imaging-guided focused ultrasound.

    PubMed

    Jolesz, Ferenc A; Hynynen, Kullervo; McDannold, Nathan; Freundlich, David; Kopelman, Doron

    2004-11-01

    A number of minimally invasive methods have been tested for the thermal ablation of liver tumors as an alternative to surgical resection. The use of focused ultrasound transducers to ablate deep tumors offers the first completely noninvasive alternative to these techniques. By increasing the flexibility of this technology with modern phased-array transducer design and by combining it with magnetic resonance imaging for targeting and online guidance, a powerful tool results with the potential to offer treatment to a larger population of patients, to reduce trauma to the patient, and to reduce the cost of treatment. In this article, we review previous work with focused ultrasound in the liver and recent experimental results with magnetic resonance imaging guidance.

  6. Magnetic Resonance-Guided Focused Ultrasound Neurosurgery for Essential Tremor: A Health Technology Assessment

    PubMed Central

    Schaink, Alexis; Li, Chunmei; Gajic-Veljanoski, Olga; Wells, David; Higgins, Caroline

    2018-01-01

    Background The standard treatment option for medication-refractory essential tremor is invasive neurosurgery. A new, noninvasive alternative is magnetic resonance-guided focused ultrasound (MRgFUS) neurosurgery. We aimed to determine the effectiveness, safety, and cost-effectiveness of MRgFUS neurosurgery for the treatment of moderate to severe, medication-refractory essential tremor in Ontario. We also spoke with people with essential tremor to gain an understanding of their experiences and thoughts regarding treatment options, including MRgFUS neurosurgery. Methods We performed a systematic review of the clinical literature published up to April 11, 2017, that examined MRgFUS neurosurgery alone or compared with other interventions for the treatment of moderate to severe, medication-refractory essential tremor. We assessed the risk of bias of each study and the quality of the body of evidence according to the Grading of Recommendations Assessment, Development, and Evaluation (GRADE) Working Group criteria. We performed a systematic review of the economic literature and created Markov cohort models to assess the cost-effectiveness of MRgFUS neurosurgery compared with other treatment options, including no surgery. We also estimated the budget impact of publicly funding MRgFUS neurosurgery in Ontario for the next 5 years. To contextualize the potential value of MRgFUS neurosurgery as a treatment option for essential tremor, we spoke with people with essential tremor and their families. Results Nine studies met our inclusion criteria for the clinical evidence review. In noncomparative studies, MRgFUS neurosurgery was found to significantly improve tremor severity and quality of life and to significantly reduce functional disability (GRADE: very low). It was also found to be significantly more effective than a sham procedure (GRADE: high). We found no significant difference in improvements in tremor severity, functional disability, or quality of life between MRg

  7. Magnetically-focusing biochip structures for high-speed active biosensing with improved selectivity.

    PubMed

    Yoo, Haneul; Lee, Dong Jun; Kim, Daesan; Park, Juhun; Chen, Xing; Hong, Seunghun

    2018-06-29

    We report a magnetically-focusing biochip structure enabling a single layered magnetic trap-and-release cycle for biosensors with an improved detection speed and selectivity. Here, magnetic beads functionalized with specific receptor molecules were utilized to trap target molecules in a solution and transport actively to and away from the sensor surfaces to enhance the detection speed and reduce the non-specific bindings, respectively. Using our method, we demonstrated the high speed detection of IL-13 antigens with the improved detection speed by more than an order of magnitude. Furthermore, the release step in our method was found to reduce the non-specific bindings and improve the selectivity and sensitivity of biosensors. This method is a simple but powerful strategy and should open up various applications such as ultra-fast biosensors for point-of-care services.

  8. Magnetically-focusing biochip structures for high-speed active biosensing with improved selectivity

    NASA Astrophysics Data System (ADS)

    Yoo, Haneul; Lee, Dong Jun; Kim, Daesan; Park, Juhun; Chen, Xing; Hong, Seunghun

    2018-06-01

    We report a magnetically-focusing biochip structure enabling a single layered magnetic trap-and-release cycle for biosensors with an improved detection speed and selectivity. Here, magnetic beads functionalized with specific receptor molecules were utilized to trap target molecules in a solution and transport actively to and away from the sensor surfaces to enhance the detection speed and reduce the non-specific bindings, respectively. Using our method, we demonstrated the high speed detection of IL-13 antigens with the improved detection speed by more than an order of magnitude. Furthermore, the release step in our method was found to reduce the non-specific bindings and improve the selectivity and sensitivity of biosensors. This method is a simple but powerful strategy and should open up various applications such as ultra-fast biosensors for point-of-care services.

  9. Probing the magnetic moment of FePt micromagnets prepared by focused ion beam milling

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Overweg, H. C.; Haan, A. M. J. den; Eerkens, H. J.

    2015-08-17

    We investigate the degradation of the magnetic moment of a 300 nm thick FePt film induced by Focused Ion Beam (FIB) milling. A 1 μm × 8 μm rod is milled out of a film by a FIB process and is attached to a cantilever by electron beam induced deposition. Its magnetic moment is determined by frequency-shift cantilever magnetometry. We find that the magnetic moment of the rod is μ = 1.1 ± 0.1 × 10{sup −12} Am{sup 2}, which implies that 70% of the magnetic moment is preserved during the FIB milling process. This result has important implications for atom trapping and magnetic resonance force microscopy, which are addressed inmore » this paper.« less

  10. Analysis of Scanned Probe Images for Magnetic Focusing in Graphene

    DOE PAGES

    Bhandari, Sagar; Lee, Gil-Ho; Kim, Philip; ...

    2017-02-21

    We have used cooled scanning probe microscopy (SPM) to study electron motion in nanoscale devices. The charged tip of the microscope was raster-scanned at constant height above the surface as the conductance of the device was measured. The image charge scatters electrons away, changing the path of electrons through the sample. Using this technique, we imaged cyclotron orbits that flow between two narrow contacts in the magnetic focusing regime for ballistic hBN–graphene–hBN devices. We present herein an analysis of our magnetic focusing imaging results based on the effects of the tip-created charge density dip on the motion of ballistic electrons.more » The density dip locally reduces the Fermi energy, creating a force that pushes electrons away from the tip. When the tip is above the cyclotron orbit, electrons are deflected away from the receiving contact, creating an image by reducing the transmission between contacts. The data and our analysis suggest that the graphene edge is rather rough, and electrons scattering off the edge bounce in random directions. However, when the tip is close to the edge, it can enhance transmission by bouncing electrons away from the edge, toward the receiving contact. Our results demonstrate that cooled SPM is a promising tool to investigate the motion of electrons in ballistic graphene devices.« less

  11. Analysis of Scanned Probe Images for Magnetic Focusing in Graphene

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bhandari, Sagar; Lee, Gil-Ho; Kim, Philip

    We have used cooled scanning probe microscopy (SPM) to study electron motion in nanoscale devices. The charged tip of the microscope was raster-scanned at constant height above the surface as the conductance of the device was measured. The image charge scatters electrons away, changing the path of electrons through the sample. Using this technique, we imaged cyclotron orbits that flow between two narrow contacts in the magnetic focusing regime for ballistic hBN–graphene–hBN devices. We present herein an analysis of our magnetic focusing imaging results based on the effects of the tip-created charge density dip on the motion of ballistic electrons.more » The density dip locally reduces the Fermi energy, creating a force that pushes electrons away from the tip. When the tip is above the cyclotron orbit, electrons are deflected away from the receiving contact, creating an image by reducing the transmission between contacts. The data and our analysis suggest that the graphene edge is rather rough, and electrons scattering off the edge bounce in random directions. However, when the tip is close to the edge, it can enhance transmission by bouncing electrons away from the edge, toward the receiving contact. Our results demonstrate that cooled SPM is a promising tool to investigate the motion of electrons in ballistic graphene devices.« less

  12. Pb/InAs nanowire josephson junction with high critical current and magnetic flux focusing.

    PubMed

    Paajaste, J; Amado, M; Roddaro, S; Bergeret, F S; Ercolani, D; Sorba, L; Giazotto, F

    2015-03-11

    We have studied mesoscopic Josephson junctions formed by highly n-doped InAs nanowires and superconducting Ti/Pb source and drain leads. The current-voltage properties of the system are investigated by varying temperature and external out-of-plane magnetic field. Superconductivity in the Pb electrodes persists up to ∼7 K and with magnetic field values up to 0.4 T. Josephson coupling at zero backgate voltage is observed up to 4.5 K and the critical current is measured to be as high as 615 nA. The supercurrent suppression as a function of the magnetic field reveals a diffraction pattern that is explained by a strong magnetic flux focusing provided by the superconducting electrodes forming the junction.

  13. Age Differences in Consumer Decision Making under Option Framing: From the Motivation Perspective

    PubMed Central

    Peng, Huamao; Xia, Shiyong; Ruan, Fanglin; Pu, Bingyan

    2016-01-01

    Option framing effect is the phenomena that participants often accept more options when they are asked to delete undesired options from a full model (subtractive framing) than they do when they are instructed to add desired options to a base model (additive framing). Whether the same effect exists in different age groups is less well known. To explore the roles of age and purchase motivations on the option framing effect for automobiles purchases, this study adopted a 3 (age group: younger, middle-aged, vs. older) × 2 (option framing: additive vs. subtractive) × 2 (focus condition: information vs. emotion) mixed design. To manipulate purchase motivations, participants in the three age groups were instructed to focus on the ratio of utility and price of options (information-focus) or the extent of pleasure induced by the options (emotion-focus) when they made purchase decisions in two framing conditions. The results revealed similar option framing effect across all age groups in the information-focus condition regarding the total price paid for accepted options. In contrast, the framing effect was not found in the emotion-focus condition. In addition, older adults accepted more options and an overall higher price than younger and middle-aged adults in both focus conditions. This difference was more obvious in the emotion-focus condition than in the information-focus condition. Moreover, both the number of accepted options and the total accepted price of the younger group in the information-focus condition were higher than those in the emotion-focus condition, whereas the older and middle-aged groups accepted same number of options and price between two focus conditions. These results imply that purchase motivation is a moderator of the option framing effect and age characteristics linked with motivations must be considered in sales. PMID:27872603

  14. Age Differences in Consumer Decision Making under Option Framing: From the Motivation Perspective.

    PubMed

    Peng, Huamao; Xia, Shiyong; Ruan, Fanglin; Pu, Bingyan

    2016-01-01

    Option framing effect is the phenomena that participants often accept more options when they are asked to delete undesired options from a full model (subtractive framing) than they do when they are instructed to add desired options to a base model (additive framing). Whether the same effect exists in different age groups is less well known. To explore the roles of age and purchase motivations on the option framing effect for automobiles purchases, this study adopted a 3 (age group: younger, middle-aged, vs. older) × 2 (option framing: additive vs. subtractive) × 2 (focus condition: information vs. emotion) mixed design. To manipulate purchase motivations, participants in the three age groups were instructed to focus on the ratio of utility and price of options (information-focus) or the extent of pleasure induced by the options (emotion-focus) when they made purchase decisions in two framing conditions. The results revealed similar option framing effect across all age groups in the information-focus condition regarding the total price paid for accepted options. In contrast, the framing effect was not found in the emotion-focus condition. In addition, older adults accepted more options and an overall higher price than younger and middle-aged adults in both focus conditions. This difference was more obvious in the emotion-focus condition than in the information-focus condition. Moreover, both the number of accepted options and the total accepted price of the younger group in the information-focus condition were higher than those in the emotion-focus condition, whereas the older and middle-aged groups accepted same number of options and price between two focus conditions. These results imply that purchase motivation is a moderator of the option framing effect and age characteristics linked with motivations must be considered in sales.

  15. Focused transport of energetic particles along magnetic field lines draped around a coronal mass ejection

    NASA Technical Reports Server (NTRS)

    Tan, L. C.; Mason, G. M.; Lee, M. A.; Klecker, B.; Ipavich, F. M.

    1992-01-01

    Evidence is presented for focused transport of energetic particles along magnetic field lines draped around a coronal mass ejection. This evidence was obtained with the University of Maryland/Max-Planck-Institute experiment on the ISEE-3 spacecraft during the decay phase of the June 6, 1979, solar particle event. During the early portion of the decay phase of this event, interplanetary magnetic field lines were apparently draped around a coronal mass ejection, leading to a small focusing length on the western flank where ISEE 3 was located. A period of very slow decrease of particle intensity was observed, along with large sunward anisotropy in the solar wind frame, which is inconsistent with predictions of the standard Fokker-Planck equation models for diffusive transport. It was found possible to fit the observations, assuming that focused transport dominates and that the particle pitch angle scattering is isotropic.

  16. Ultra-long magnetization needle induced by focusing azimuthally polarized beams with a spherical mirror.

    PubMed

    Hang, Li; Luo, Kai; Fu, Jian; Chang, Yizhe; Wang, Ying; Chen, Peifeng

    2018-03-20

    Based on extended Richards-Wolf theory for axisymmetric surfaces and the inverse Faraday effect, we propose the generation of a purely longitudinal magnetization needle by focusing Gaussian annular azimuthally polarized beams with a spherical mirror. The needle obtained has a longitudinal length varying hundreds to thousands of wavelengths while keeping the lateral size under 0.4λ, and the corresponding aspect ratio can easily reach more than 2000. It may be the first time that a magnetization needle whose aspect ratio is over 500 has been achieved. The approximate analytical expressions of the magnetization needle are given, and the longitudinal length is tunable by changing the value of the angular thickness and the position of the annular beams.

  17. Open-source, small-animal magnetic resonance-guided focused ultrasound system.

    PubMed

    Poorman, Megan E; Chaplin, Vandiver L; Wilkens, Ken; Dockery, Mary D; Giorgio, Todd D; Grissom, William A; Caskey, Charles F

    2016-01-01

    MR-guided focused ultrasound or high-intensity focused ultrasound (MRgFUS/MRgHIFU) is a non-invasive therapeutic modality with many potential applications in areas such as cancer therapy, drug delivery, and blood-brain barrier opening. However, the large financial costs involved in developing preclinical MRgFUS systems represent a barrier to research groups interested in developing new techniques and applications. We aim to mitigate these challenges by detailing a validated, open-source preclinical MRgFUS system capable of delivering thermal and mechanical FUS in a quantifiable and repeatable manner under real-time MRI guidance. A hardware and software package was developed that includes closed-loop feedback controlled thermometry code and CAD drawings for a therapy table designed for a preclinical MRI scanner. For thermal treatments, the modular software uses a proportional integral derivative controller to maintain a precise focal temperature rise in the target given input from MR phase images obtained concurrently. The software computes the required voltage output and transmits it to a FUS transducer that is embedded in the delivery table within the magnet bore. The delivery table holds the FUS transducer, a small animal and its monitoring equipment, and a transmit/receive RF coil. The transducer is coupled to the animal via a water bath and is translatable in two dimensions from outside the magnet. The transducer is driven by a waveform generator and amplifier controlled by real-time software in Matlab. MR acoustic radiation force imaging is also implemented to confirm the position of the focus for mechanical and thermal treatments. The system was validated in tissue-mimicking phantoms and in vivo during murine tumor hyperthermia treatments. Sonications were successfully controlled over a range of temperatures and thermal doses for up to 20 min with minimal temperature overshoot. MR thermometry was validated with an optical temperature probe, and focus

  18. A Superstrong Adjustable Permanent Magnet for the Final Focus Quadrupole in a Linear Collider

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mihara, T.

    A super strong permanent magnet quadrupole (PMQ) was fabricated and tested. It has an integrated strength of 28.5T with overall length of 10 cm and a 7mm bore radius. The final focus quadrupole of a linear collider needs a variable focal length. This can be obtained by slicing the magnet into pieces along the beamline direction and rotating these slices. But this technique may lead to movement of the magnetic center and introduction of a skew quadrupole component when the strength is varied. A ''double ring structure'' can ease these effects. A second prototype PMQ, containing thermal compensation materials andmore » with a double ring structure, has been fabricated. Worm gear is selected as the mechanical rotating scheme because the double ring structure needs a large torque to rotate magnets. The structure of the second prototype PMQ is shown.« less

  19. The origins of options.

    PubMed

    Smaldino, Paul E; Richerson, Peter J

    2012-01-01

    Most research on decision making has focused on how human or animal decision makers choose between two or more options, posed in advance by the researchers. The mechanisms by which options are generated for most decisions, however, are not well understood. Models of sequential search have examined the trade-off between continued exploration and choosing one's current best option, but still cannot explain the processes by which new options are generated. We argue that understanding the origins of options is a crucial but untapped area for decision making research. We explore a number of factors which influence the generation of options, which fall broadly into two categories: psycho-biological and socio-cultural. The former category includes factors such as perceptual biases and associative memory networks. The latter category relies on the incredible human capacity for culture and social learning, which doubtless shape not only our choices but the options available for choice. Our intention is to start a discussion that brings us closer toward understanding the origins of options.

  20. The Origins of Options

    PubMed Central

    Smaldino, Paul E.; Richerson, Peter J.

    2012-01-01

    Most research on decision making has focused on how human or animal decision makers choose between two or more options, posed in advance by the researchers. The mechanisms by which options are generated for most decisions, however, are not well understood. Models of sequential search have examined the trade-off between continued exploration and choosing one’s current best option, but still cannot explain the processes by which new options are generated. We argue that understanding the origins of options is a crucial but untapped area for decision making research. We explore a number of factors which influence the generation of options, which fall broadly into two categories: psycho-biological and socio-cultural. The former category includes factors such as perceptual biases and associative memory networks. The latter category relies on the incredible human capacity for culture and social learning, which doubtless shape not only our choices but the options available for choice. Our intention is to start a discussion that brings us closer toward understanding the origins of options. PMID:22514515

  1. Magnetic Resonance-Guided High-Intensity Focused Ultrasound (MR-HIFU) in Treatment of Symptomatic Uterine Myomas

    PubMed Central

    Filipowska, Justyna; Łoziński, Tomasz

    2014-01-01

    Summary Magnetic Resonance-guided High-Intensity Focused Ultrasound (MR-HIFU) is a noninvasive technique for ablation therapy for uterine myomas, where focused ultrasound energy beam generates localized high temperature in the selected area and coagulates chosen tissue, leaving the skin and tissues in between unharmed. Magnetic resonance imaging enables accurate targeting for HIFU as well as temperature monitoring during treatment. MR guidance with 3D anatomical imaging provides reference data for treatment planning, while real-time temperature monitoring aids in controlling ablation process. This review provides basic information regarding methodology, clinical indications for this kind of treatment, expected outcome and patient management during MR-HIFU procedure. The aim of this work is to introduce a new, noninvasive treatment method for uterine leiomyomas and to present a comparison with other currently used methods. PMID:25469176

  2. Magnetic Resonance-Guided High-Intensity Focused Ultrasound (MR-HIFU) in Treatment of Symptomatic Uterine Myomas.

    PubMed

    Filipowska, Justyna; Loziński, Tomasz

    2014-01-01

    Magnetic Resonance-guided High-Intensity Focused Ultrasound (MR-HIFU) is a noninvasive technique for ablation therapy for uterine myomas, where focused ultrasound energy beam generates localized high temperature in the selected area and coagulates chosen tissue, leaving the skin and tissues in between unharmed. Magnetic resonance imaging enables accurate targeting for HIFU as well as temperature monitoring during treatment. MR guidance with 3D anatomical imaging provides reference data for treatment planning, while real-time temperature monitoring aids in controlling ablation process. This review provides basic information regarding methodology, clinical indications for this kind of treatment, expected outcome and patient management during MR-HIFU procedure. The aim of this work is to introduce a new, noninvasive treatment method for uterine leiomyomas and to present a comparison with other currently used methods.

  3. Quantitative Magnetic Resonance Thermometry and Its Use with MR-Guided Focused Ultrasound

    NASA Astrophysics Data System (ADS)

    Pauly, Kim

    2014-03-01

    Focused ultrasound (FUS) uses a large area array, typically outside the body, that is geometrically or electronically focused to a point deep in the body. Such focusing provides amplification of the ultrasound intensity, thereby allowing heating of tissue to the point of coagulation at the focus, without damage to the intervening tissue. Guidance of FUS treatments deep in the body can be done quantitatively with magnetic resonance (MR) thermometry, termed MRgFUS. The physics behind MR thermometry lie in the changes in hydrogen bonding with temperature. As tissue temperature rises, hydrogen bonds break, allowing the return of the electron cloud to shield water protons, reducing the magnetic field seen by the protons, and the resonant frequency. The change in resonant frequency is -0.01 ppm per degree C and is the same for all aqueous tissues. The result of the shift in proton resonant frequency is seen in the phase of gradient echo images. Subtraction of the phase of images acquired before and during heating allows the removal of background phase from other sources, yielding quantitative temperature maps. Temperature standard deviations less than 1 degree C are readily achievable and thermal dose maps are easily calculated. Thermal dose is found from a conversion of the whole temperature-time curve to an equivalent number of minutes at 43 degrees C. A thermal dose of 240 minutes is often taken as the threshold for tissue damage. MR thermometry is complicated by the motion of the target tissue and/or motion of other organs such as occurs during respiration. More sophisticated algorithms than the simple baseline subtraction take advantage of the facts that motion can be repetitive (in the case of respiratory motion) and/or the fact that the focal region in MRgFUS is small, allowing for extraction of the heat from the phase profile without subtraction of a background phase.

  4. Focusing electrode and coaxial reflector used for reducing the guiding magnetic field of the Ku-band foilless transit-time oscillator

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ling, Junpu; Zhang, Jiande; He, Juntao, E-mail: hejuntao12@163.com

    2014-08-15

    Based on the theoretical analysis of the intense relativistic electron beam propagation in the coaxial drift-tube, a focusing electrode and a coaxial reflector is proposed to lessen the demand of the coaxial Ku-band foilless transit-time oscillator (TTO) for the guiding magnetic field. Moreover, a Ku-band TTO with the focusing electrode and the coaxial reflector is designed and studied by particle in cell simulation. When the diode voltage is 390 kV, the beam current 7.8 kA, and the guiding magnetic field is only 0.3 T, the device can output 820 MW microwave pulse at 14.25 GHz by means of the simulation.more » However, for the device without them, the output power is only 320 MW. The primary experiments are also carried out. When the guiding magnetic field is 0.3 T, the output power of the device with the focusing electrode and the coaxial reflector is double that of the one without them. The simulation and experimental results prove that the focusing electrode and the coaxial reflector are effective on reducing the guiding magnetic field of the device.« less

  5. Robotic active positioning for magnetic resonance-guided high-intensity focused ultrasound

    NASA Astrophysics Data System (ADS)

    Xiao, Xu; Huang, Zhihong; Volovick, Alexander; Melzer, Andreas

    2012-11-01

    Magnetic resonance (MR) guided High-intensity focused ultrasound (HIFU) is a noninvasive method producing thermal necrosis and cavitation at the position of tumors with high accuracy. Because the typical size of the high-intensity focused ultrasound focus are much smaller than the targeted tumor or other tissues, multiple sonications and focus repositioning become necessary for HIFU treatment. In order to reach a much wider range, manual repositioning or using MR compatible mechanical actuators could be used. The repositioning technique is a time consuming procedure because it needs a series of MR imaging to detect the transducer and markers preplaced on the mechanical devices. We combined an active tracking technique into the MR guided HIFU system. In this work, the robotic system used is the MR-compatible robotics from InnoMotion{trade mark, serif} (IBSMM, Engineering spol. s r.o. / Ltd, Czech) which is originally designed for MR-guided needle biopsy. The precision and positioning speed of the combined robotic HIFU system are evaluated in this study. Compared to the existing MR guided HIFU systems, the combined robotic system with active tracking techniques provides a potential that allows the HIFU treatment to operate in a larger spatial range and with a faster speed.

  6. Health financing options for Fiji's health system.

    PubMed

    Pande, Madhukar

    2003-09-01

    Fiji is currently implementing health care reforms with the first phase of reforms focusing on decentralization of the health system. Part of this effort focuses on looking at financing options. Some options for financing health care include private health insurance, social insurance, community financing, user-pays system (out-of-pocket), health savings accounts, government taxation and subsidies, and overseas loans and aid funding. This paper addresses all these options in detail and provides an analysis into each of these options relevance to Fiji and in some instances to other nations in the South Pacific region. Given the relative small populations of Fiji and its neighbouring nations, a regional approach to financing could prove more viable in the longer-term, however political, social, economic, legal and cultural issues will need to seriously explored.

  7. A long arm for ultrasound: a combined robotic focused ultrasound setup for magnetic resonance-guided focused ultrasound surgery.

    PubMed

    Krafft, Axel J; Jenne, Jürgen W; Maier, Florian; Stafford, R Jason; Huber, Peter E; Semmler, Wolfhard; Bock, Michael

    2010-05-01

    Focused ultrasound surgery (FUS) is a highly precise noninvasive procedure to ablate pathogenic tissue. FUS therapy is often combined with magnetic resonance (MR) imaging as MR imaging offers excellent target identification and allows for continuous monitoring of FUS induced temperature changes. As the dimensions of the ultrasound (US) focus are typically much smaller than the targeted volume, multiple sonications and focus repositioning are interleaved to scan the focus over the target volume. Focal scanning can be achieved electronically by using phased-array US transducers or mechanically by using dedicated mechanical actuators. In this study, the authors propose and evaluate the precision of a combined robotic FUS setup to overcome some of the limitations of the existing MRgFUS systems. Such systems are typically integrated into the patient table of the MR scanner and thus only provide an application of the US wave within a limited spatial range from below the patient. The fully MR-compatible robotic assistance system InnoMotion (InnoMedic GmbH, Herxheim, Germany) was originally designed for MR-guided interventions with needles. It offers five pneumatically driven degrees of freedom and can be moved over a wide range within the bore of the magnet. In this work, the robotic system was combined with a fixed-focus US transducer (frequency: 1.7 MHz; focal length: 68 mm, and numerical aperture: 0.44) that was integrated into a dedicated, in-house developed treatment unit for FUS application. A series of MR-guided focal scanning procedures was performed in a polyacrylamide-egg white gel phantom to assess the positioning accuracy of the combined FUS setup. In animal experiments with a 3-month-old domestic pig, the system's potential and suitability for MRgFUS was tested. In phantom experiments, a total targeting precision of about 3 mm was found, which is comparable to that of the existing MRgFUS systems. Focus positioning could be performed within a few seconds

  8. Colorectal cancer screening: The role of the noninvasive options.

    PubMed

    Dickerson, Lisa; Varcak, Susan Combs

    2016-09-01

    Recommended screening options for colorectal cancer are divided into noninvasive stool-based options, and invasive procedure-based options. Because multiple screening strategies are effective, efforts to reduce deaths from colorectal cancer should focus on maximizing the number of patients who are screened. This article reviews noninvasive stool-based screening options.

  9. Viable Options for Fertility Preservation in Breast Cancer Patients: A Focus on Latin America.

    PubMed

    Lambertini, Matteo; Goldrat, Oranite; Barragan-Carrillo, Regina; Viglietti, Giulia; Demeestere, Isabelle; Villarreal-Garza, Cynthia

    2017-01-01

    Thanks to the improved survival outcomes observed in recent years, a growing attention has been given to the quality of life issues faced by young women with breast cancer such as fertility preservation and concerns related to future pregnancies. However, several challenges remain for young women with breast cancer considering undergoing fertility preservation strategies. Further specific issues on this regard should be taken into account in Latin America, where patients and physicians face particular barriers that hinder the routine adoption of this practice. Hence, further efforts are needed to overcome these deficiencies and improve the correct referral of breast cancer patients to fertility preservation strategies. The aim of the present review is to focus on the risk of anticancer treatment-related premature ovarian failure and infertility in young breast cancer patients, to summarize the current knowledge on the available options for fertility preservation, and to discuss the safety issues of pregnancy in breast cancer survivors. Furthermore, this review aims to highlight the specific clinical challenges in this field encountered by healthcare providers and young breast cancer patients from Latin American countries.

  10. Focused Ultrasound Surgery for Uterine Fibroids

    MedlinePlus

    ... ultrasound surgery, your doctor may perform a pelvic magnetic resonance imaging (MRI) scan before treatment. Focused ultrasound surgery — also called magnetic resonance-guided focused ultrasound surgery or focused ultrasound ...

  11. Design, construction and evaluation of a 12.045 GHz, 2.0 kW-cw permanent-magnet focused klystron amplifier

    NASA Technical Reports Server (NTRS)

    Nishida, J. M.

    1975-01-01

    An analytical and experimental program to demonstrate the technical feasibility of a lightweight, high-efficiency, 1-2 kW cw, permanent magnet focused klystron operating at 12.0 GHz was described. The design is based on use of a samarium-cobalt permanent magnet for focusing of the electron beam and choice of the most optimum parameters for maximum efficiency. A filter-loaded output circuit is used for the required bandwidth. The design incorporates a collector which is demountable from the tube to facilitate multistage depressed collector experiments, permitting replacement with a NASA-designed axisymmetric, electrostatic collector for linear beam microwave tubes. A further requirement is that the focusing field between the last interaction gap and the collector decay in a prescribed manner referred to as adiabatic expansion.

  12. 3D magnetic nanostructures grown by focused electron and ion beam induced deposition

    NASA Astrophysics Data System (ADS)

    Fernandez-Pacheco, Amalio

    Three-dimensional nanomagnetism is an emerging research area, where magnetic nanostructures extend along the whole space, presenting novel functionalities not limited to the substrate plane. The development of this field could have a revolutionary impact in fields such as electronics, the Internet of Things or bio-applications. In this contribution, I will show our recent work on 3D magnetic nanostructures grown by focused electron and ion beam induced deposition. This 3D nano-printing techniques, based on the local chemical vapor deposition of a gas via the interaction with electrons and ions, makes the fabrication of complex 3D magnetic nanostructures possible. First, I will show how by exploiting different growth regimes, suspended Cobalt nanowires with modulated diameter can be patterned, with potential as domain wall devices. Afterwards, I will show recent results where the synthesis of Iron-Gallium alloys can be exploited in the field of artificial multiferroics. Moreover, we are developing novel methodologies combining physical vapor deposition and 3D nano-printing, creating Permalloy 3D nanostrips with controllable widths and lengths up to a few microns. This approach has been extended to more complex geometries by exploiting advanced simulation growth techniques combining Monte Carlo and continuum model methods. Throughout the talk, I will show the methodology we are following to characterize 3D magnetic nanostructures, by combining magneto-optical Kerr effect, scanning probe microscopy and electron and X-R magnetic imaging, and I will highlight some of the challenges and opportunities when studying these structures. I acknowledge funding from EPSRC and the Winton Foundation.

  13. Acoustic characterization of Thiel liver for magnetic resonance-guided focused ultrasound treatment.

    PubMed

    Karakitsios, Ioannis; Joy, Joyce; Mihcin, Senay; Melzer, Andreas

    2017-04-01

    The purpose of this work was to measure the essential acoustic parameters, i.e., acoustic impedance, reflection coefficient, attenuation coefficient, of Thiel embalmed human and animal liver. The Thiel embalmed tissue can be a promising, pre-clinical model to study liver treatment with Magnetic Resonance-guided Focused Ultrasound (MRgFUS). Using a single-element transducer and the contact pulse-echo method, the acoustic parameters, i.e., acoustic impedance, reflection coefficient and attenuation coefficient of Thiel embalmed human and animal liver were measured. The Thiel embalmed livers had higher impedance, similar reflection and lower attenuation compared to the fresh tissue. Embalming liver with Thiel fluid affects its acoustic properties. During MRgFUS sonication of a Thiel organ, more focused ultrasound (FUS) will be backscattered by the organ, and higher acoustic powers are required to reach coagulation levels (temperatures >56 °C).

  14. Design and Development of a Prototype Permanent Magnet for Focusing/Defocusing for Electron-Ion Colliders

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wagner, Bob

    Electron-ion colliders (EIC) have been identified as an ideal tool to study the next frontier of nuclear physics – the gluon force that holds the building blocks of matter together, and which is a fundamental component of the theory of Quantum Chromodynamics (QCD). Future electron-ion colliders under consideration can be based on the Energy Recovery Linac (ERL) architecture. The beam lines for this architecture could be built of the newly developed Non-Scaling Fixed Field Alternating Gradient (NS FFAG) structure, so that they can transfer multiple energies within the same aperture. This structure allows for the use of compact, economical quadupolemore » permanent magnets. In this SBIR, we propose to design and to manufacture prototype quadrupole permanent magnets of focusing/defocusing combined function for use in this beam line. For our SBIR project, we proposed to design and build the focusing/defocusing quadrupole with a gradient strength of 50 T/m and with a beam gap of 16mm. The proposed permanent magnet material is SmCo because of its higher radiation resistance as compared to NdBFe2. The use of permanent magnets will reduce the overall cost. For Phase I, we took a recent design by Dr. Dejan Trbojevic, and reran Tosca code on the design to optimize the iron yoke with respect to the thickness of SmCo. We then fabricated one prototype focusing/defocusing combined function quadruple and measured field quality dG/Go. Our plan for Phase II is that, based on our Phase I prototype experience, we shall improve the design and fabricate a production quadruple, and design and incorporate coils for skew dipoles and normal quadrupole correctors, etc. In addition, we shall fabricate enough quadrupoles for one cell. The development of quadrupole permanent magnets is of fundamental importance for there application in the future electron-ion colliders. This accelerator structure will also advance the development of muon accelerators and allow for the development of

  15. Dialogue for Change. Options for Re-Structuring K-12 Education. 3rd Edition, 1988.

    ERIC Educational Resources Information Center

    Metropolitan Affairs Corp., Detroit, MI.

    This Third Edition of the 1985 report, "Dialogue for Change," discusses options and examples of educational choice and teacher empowerment and summarizes developments between 1985 and 1987. The following key options are discussed in Chapter 1, "Proposed Options for Change": (1) magnet schools; (2) open enrollment; (3) purchase…

  16. The Fundamental Uncertainty of Business: Real Options

    NASA Astrophysics Data System (ADS)

    Dyer, James S.

    The purpose of this paper is to discuss the manner in which uncertainty is currently evaluated in business, with an emphasis on economic measures. In recent years, the accepted approach for the valuation of capital investment decisions has become one based on the theory of real options. From the standpoint of this workshop, the interesting aspect of real options is its focus on the flexibility of management to respond to changes in the environment as a feature of an alternative that has unique value, known as "option value." While this may not be surprising to most participants in this workshop, it does represent a radical change in traditional thinking about risk in business, where efforts have primarily been focused on the elimination of risk when possible.

  17. Multi-objective inverse design of sub-wavelength optical focusing structures for heat assisted magnetic recording

    NASA Astrophysics Data System (ADS)

    Bhargava, Samarth; Yablonovitch, Eli

    2014-09-01

    We report using Inverse Electromagnetic Design to computationally optimize the geometric shapes of metallic optical antennas or near-field transducers (NFTs) and dielectric waveguide structures that comprise a sub-wavelength optical focusing system for practical use in Heat Assisted Magnetic Recording (HAMR). This magnetic data-recording scheme relies on focusing optical energy to locally heat the area of a single bit, several hundred square nanometers on a hard disk, to the Curie temperature of the magnetic storage layer. There are three specifications of the optical system that must be met to enable HAMR as a commercial technology. First, to heat the media at scan rates upward of 10 m/s, ~1mW of light (<1% of typical laser diode output power) must be focused to a 30nm×30nm spot on the media. Second, the required lifetime of many years necessitates that the nano-scale NFT must not over-heat from optical absorption. Third, to avoid undesired erasing or interference of adjacent tracks on the media, there must be minimal stray optical radiation away from the hotspot on the hard disk. One cannot design the light delivery system by tackling each of these challenges independently, because they are governed by coupled electromagnetic phenomena. Instead, we propose multiobjective optimization using Inverse Electromagnetic Design in conjunction with a commercial 3D FDTD Maxwell's equations solver. We computationally generated designs of a metallic NFT and a high-index waveguide grating that meet the HAMR specifications simultaneously. Compared to a mock industry design, our proposed design has a similar optical coupling efficiency, ~3x improved suppression of stray optical radiation, and a 60% (280°C) reduction in NFT temperature rise. We also distributed the Inverse Electromagnetic Design software online so that industry partners can use it as a repeatable design process.

  18. MR-guided Focused Ultrasound for Uterine Fibroids

    MedlinePlus

    ... Professions Site Index A-Z MR-guided Focused Ultrasound for Uterine Fibroids Magnetic Resonance-guided Focused Ultrasound ( ... are the limitations of MRgFUS? What is Focused Ultrasound of Uterine Fibroids? Magnetic Resonance-guided Focused Ultrasound ( ...

  19. Quantum transport modeling of magnetic focusing in graphene p-n junctions

    NASA Astrophysics Data System (ADS)

    Lagasse, Samuel; Lee, Ji Ung

    We demonstrate a new model for studying transverse magnetic focusing experiments in graphene p-n junctions, using quantum transport methods. By including a combination of dephasing edge contacts and Landauer-Büttiker multi-terminal analysis, we observe an exceptional degree of agreement with recent experimental data from Chen et al, without fitting parameters. Our model captures both the resonance and off-resonance non-local resistances from experiment. Our calculated quantum transmission functions indicate the origin of the sign of the measured resistance. Spatially resolved flow maps of local particle current density are used to explain our results and rapidly convey the mechanisms of device operation. Mode-by-mode analysis of transport shows the complex interplay between semi-classical skipping orbits and quantum effects. Quantum interference, p-n filtering, and edge scattering are clearly seen. Additionally, we are able to explain subtle features from experiment, such as the p-p- to p-p+ transition and the second p-n focusing resonance. The authors acknolwedge financial support provided by the U.S. Naval Research Laboratory (Grant Number: N00173-14-1-G017).

  20. Permanent magnet motors

    NASA Astrophysics Data System (ADS)

    Richter, E.

    1984-09-01

    The work deals with the design and analysis study for the conceptual design of an economical high efficiency ac motor based on permanent magnets. The design and trade off studies have covered the material considerations, the design tradeoff options as well as transient and steady state performance considerations, and other options. The baseline comparison is the high efficiency induction motor. The permanent magnet (PM) motor must fit into the same frame size and surpass the induction motor on a life cost basis that includes 2.5 years of operation at a 50% duty cycle. It is shown that a motor based upon ferrite magnets does meet the objectives of the program in ratings of up to 25 hp. A 7.5 motor design is carried through the conceptual design stage.

  1. Tooth-supported, magnet-retained overdentures: a review.

    PubMed

    Vere, Joe; Deans, Robert F

    2009-06-01

    There has been an increase in the provision of implant-supported prostheses in patients unable to tolerate conventional dentures. Unfortunately, many patients are unable to benefit from this treatment option because of anatomical, medical or financial constraints. Magnet-retained overdentures represent a potential treatment option in many of these cases. This article describes the development, advantages, complications and clinical procedures associated with the provision of tooth-supported, magnet-retained overdentures. Conventional overdenture retention can be enhanced by the use of dental magnets. Clinical procedures are straightforward and magnets offer a number of advantages over other forms of precision attachment.

  2. Overdentures with magnetic attachments.

    PubMed

    Gillings, B R; Samant, A

    1990-10-01

    Magnets were used only occasionally for dental purposes several decades ago. Since the advent of rare earth magnet alloys, however, intraoral magnets are shaping the course of aesthetics and retention for both complete and removable partial overdentures. Their benefits include simplicity, low cost, self-adjustment, inherent stress breaking, automatic reseating after denture displacement, comparative freedom of lateral denture movement, a low potential for trauma to the retained roots, and elimination of the need for adjustment in service. The clinical procedures involved in their application do not require any special skills, and the options offered by the various manufacturers give the dentist a wide variety of choices in selecting an appropriate treatment plan. Clinical experience has shown that magnetic retention offers an economical alternative for teeth that would otherwise require expensive or extensive restorative treatment, and can be used as an effective and often superior replacement for failed bridgework. Finally, it is clear that overdenture treatment per se is a valuable option for the dentist, and the use of magnets expands this option to the retention of tooth roots that might otherwise be scheduled for extraction. The natural tooth root, even if periodontally involved, can serve as a useful aid in denture support and retention, and should be regarded as at least as good as, and in most cases superior to, an implant. It is also much less expensive.

  3. Magnetic nanoparticles: In vivo cancer diagnosis and therapy.

    PubMed

    Lima-Tenório, Michele K; Pineda, Edgardo A Gómez; Ahmad, Nasir M; Fessi, Hatem; Elaissari, Abdelhamid

    2015-09-30

    Recently, significant research efforts have been devoted to the finding of efficient approaches in order to reduce the side effects of traditional cancer therapy and diagnosis. In this context, magnetic nanoparticles have attracted much attention because of their unique physical properties, magnetic susceptibility, biocompatibility, stability and many more relevant characteristics. Particularly, magnetic nanoparticles for in vivo biomedical applications need to fulfill special criteria with respect to size, size distribution, surface charge, biodegradability or bio-eliminability and optionally bear well selected ligands for specific targeting. In this context, many routes have been developed to synthesize these materials, and tune their functionalities through intriguing techniques including functionalization, coating and encapsulation strategies. In this review article, the use of magnetic nanoparticles for cancer therapy and diagnosis is evaluated addressing potential applications in MRI, drug delivery, hyperthermia, theranostics and several other domains. In view of potential biomedical applications of magnetic nanoparticles, the review focuses on the most recent progress made with respect to synthetic routes to produce magnetic nanoparticles and their salient accomplishments for in vivo cancer diagnosis and therapy. Copyright © 2015 Elsevier B.V. All rights reserved.

  4. Magnetic resonance imaging of boiling induced by high intensity focused ultrasound

    PubMed Central

    Khokhlova, Tatiana D.; Canney, Michael S.; Lee, Donghoon; Marro, Kenneth I.; Crum, Lawrence A.; Khokhlova, Vera A.; Bailey, Michael R.

    2009-01-01

    Both mechanically induced acoustic cavitation and thermally induced boiling can occur during high intensity focused ultrasound (HIFU) medical therapy. The goal was to monitor the temperature as boiling was approached using magnetic resonance imaging (MRI). Tissue phantoms were heated for 20 s in a 4.7-T magnet using a 2-MHz HIFU source with an aperture and radius of curvature of 44 mm. The peak focal pressure was 27.5 MPa with corresponding beam width of 0.5 mm. The temperature measured in a single MRI voxel by water proton resonance frequency shift attained a maximum value of only 73 °C after 7 s of continuous HIFU exposure when boiling started. Boiling was detected by visual observation, by appearance on the MR images, and by a marked change in the HIFU source power. Nonlinear modeling of the acoustic field combined with a heat transfer equation predicted 100 °C after 7 s of exposure. Averaging of the calculated temperature field over the volume of the MRI voxel (0.3×0.5×2 mm3) yielded a maximum of 73 °C that agreed with the MR thermometry measurement. These results have implications for the use of MRI-determined temperature values to guide treatments with clinical HIFU systems. PMID:19354416

  5. Pawnee Nation Energy Option Analyses

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Matlock, M.; Kersey, K.; Riding In, C.

    2009-07-31

    In 2003, the Pawnee Nation leadership identified the need for the tribe to comprehensively address its energy issues. During a strategic energy planning workshop a general framework was laid out and the Pawnee Nation Energy Task Force was created to work toward further development of the tribe’s energy vision. The overarching goals of the “first steps” project were to identify the most appropriate focus for its strategic energy initiatives going forward, and to provide information necessary to take the next steps in pursuit of the “best fit” energy options. Based on the request of Pawnee Nation’s Energy Task Force themore » research team, consisting Tribal personnel and Summit Blue Consulting, focused on a review of renewable energy resource development potential, funding sources and utility organizational along with energy savings options. Elements of the energy demand forecasting and characterization and demand side options review remained in the scope of work, but were only addressed at a high level. Description of Activities Performed Renewable Energy Resource Development Potential The research team reviewed existing data pertaining to the availability of biomass (focusing on woody biomass, agricultural biomass/bio-energy crops, and methane capture), solar, wind and hydropower resources on the Pawnee-owned lands. Using these data, combined with assumptions about costs and revenue streams, the research team performed preliminary feasibility assessments for each resource category. The research team also reviewed available funding resources and made recommendations to Pawnee Nation highlighting those resources with the greatest potential for financially-viable development, both in the near-term and over a longer time horizon. Energy Efficiency Options While this was not a major focus of the project, the research team highlighted common strategies for reducing energy use in buildings. The team also discussed the benefits of adopting a building energy

  6. A Tabletop Persistent-Mode, Liquid-Helium-Free, 1.5-T/90-mm MgB2 "Finger" MRI Magnet for Osteoporosis Screening: Two Design Options.

    PubMed

    Park, Dongkeun; Bascuñán, Juan; Michael, Philip C; Iwasa, Yukikazu

    2018-04-01

    In this paper we present two design options for a tabletop liquid-helium-free, persistent-mode 1.5-T/90-mm MgB 2 "finger" MRI magnet for osteoporosis screening. Both designs, one with and the other without an iron yoke, satisfy the following criteria: 1) 1.5-T center field with a 90-mm room-temperature bore for a finger to be placed at the magnet center; 2) spatial field homogeneity of <5 ppm over a 20-mm diameter of spherical volume (DSV); 3) persistent-mode operation with temporal stability of <0.1 ppm/hr; 4) liquid-helium-free operation; 5) 5-gauss fringe field radius of <50 cm from the magnet center; and 6) small and light enough for placement on an exam table. Although the magnet is designed to operate nominally at 10 K, maintained by a cryocooler, it has a 5-K temperature margin to keep its 1.5-T persistent field up to 15 K. The magnet will be immersed in a volume of solid nitrogen (SN 2 ) that provides additional thermal mass when the cryocooler is switched off to provide a vibration-free measurement environment. The SN 2 enables the magnet to maintain its persistent field over a period of time sufficient for quiescent measurement, while still limiting the magnet operating temperature to ≤15 K. We discuss first pros and cons of each design, and then further studies of our proposed MgB 2 finger MRI magnet.

  7. Expensing options solves nothing.

    PubMed

    Sahlman, William A

    2002-12-01

    The use of stock options for executive compensation has become a lightning rod for public anger, and it's easy to see why. Many top executives grew hugely rich on the back of the gains they made on their options, profits they've been able to keep even as the value they were supposed to create disappeared. The supposed scam works like this: Current accounting regulations let companies ignore the cost of option grants on their income statements, so they can award valuable option packages without affecting reported earnings. Not charging the cost of the grants supposedly leads to overstated earnings, which purportedly translate into unrealistically high share prices, permitting top executives to realize big gains when they exercise their options. If an accounting anomaly is the problem, then the solution seems obvious: Write off executive share options against the current year's revenues. The trouble is, Sahlman writes, expensing option grants won't give us a more accurate view of earnings, won't add any information not already included in the financial statements, and won't even lead to equal treatment of different forms of executive pay. Far worse, expensing evades the real issue, which is whether compensation (options and other-wise) does what it's supposed to do--namely, help a company recruit, retain, and provide the right people with appropriate performance incentives. Any performance-based compensation system has the potential to encourage cheating. Only ethical management, sensible governance, adequate internal control systems, and comprehensive disclosure will save the investor from disaster. If, Sahlman warns, we pass laws that require the expensing of options, thinking that's fixed the fundamental flaws in corporate America's accounting, we will have missed a golden opportunity to focus on the much more extensive defects in the present system.

  8. Ion irradiation effects on a magnetic Si/Ni/Si trilayer and lateral magnetic-nonmagnetic multistrip patterning by focused ion beam

    NASA Astrophysics Data System (ADS)

    Dev, B. N.; Banu, Nasrin; Fassbender, J.; Grenzer, J.; Schell, N.; Bischoff, L.; Groetzschel, R.; McCord, J.

    2017-10-01

    Fabrication of a multistrip magnetic/nonmagnetic structure in a thin sandwiched Ni layer [Si(5 nm)/Ni(15 nm)/Si] by a focused ion beam (FIB) irradiation has been attempted. A control experiment was initially performed by irradiation with a standard 30 keV Ga ion beam at various fluences. Analyses were carried out by Rutherford backscattering spectrometry, X-ray reflectivity, magnetooptical Kerr effect (MOKE) measurements and MOKE microscopy. With increasing ion fluence, the coercivity as well as Kerr rotation decreases. A threshold ion fluence has been identified, where ferromagnetism of the Ni layer is lost at room temperature and due to Si incorporation into the Ni layer, a Ni0.68Si0.32 alloy layer is formed. This fluence was used in FIB irradiation of parallel 50 nm wide stripes, leaving 1 µm wide unirradiated stripes in between. MOKE microscopy on this FIB-patterned sample has revealed interacting magnetic domains across several stripes. Considering shape anisotropy effects, which would favour an alignment of magnetization parallel to the stripe axis, the opposite behaviour is observed. Magneto-elastic effects introducing a stress-induced anisotropy component oriented perpendicular to the stripe axis are the most plausible explanation for the observed behaviour.

  9. The cognitive and neural basis of option generation and subsequent choice.

    PubMed

    Kaiser, Stefan; Simon, Joe J; Kalis, Annemarie; Schweizer, Sophie; Tobler, Philippe N; Mojzisch, Andreas

    2013-12-01

    Decision-making research has thoroughly investigated how people choose from a set of externally provided options. However, in ill-structured real-world environments, possible options for action are not defined by the situation but have to be generated by the agent. Here, we apply behavioral analysis (Study 1) and functional magnetic resonance imaging (Study 2) to investigate option generation and subsequent choice. For this purpose, we employ a new experimental task that requires participants to generate options for simple real-world scenarios and to subsequently decide among the generated options. Correlational analysis with a cognitive test battery suggests that retrieval of options from long-term memory is a relevant process during option generation. The results of the fMRI study demonstrate that option generation in simple real-world scenarios recruits the anterior prefrontal cortex. Furthermore, we show that choice behavior and its neural correlates differ between self-generated and externally provided options. Specifically, choice between self-generated options is associated with stronger recruitment of the dorsal anterior cingulate cortex. This impact of option generation on subsequent choice underlines the need for an expanded model of decision making to accommodate choice between self-generated options.

  10. Nano-catalysts with Magnetic Core: Sustainable Options for Greener Synthesis

    EPA Science Inventory

    Author’s perspective on nano-catalysts with magnetic core is summarized with recent work from his laboratory. Magnetically recyclable nano-catalysts and their use in benign media is an ideal blend for the development of sustainable methodologies in organic synthesis. Water or pol...

  11. Fibromyalgia Pathogenesis and Treatment Options Update.

    PubMed

    Chinn, Steven; Caldwell, William; Gritsenko, Karina

    2016-04-01

    This review article presents and summarizes up-to-date literature on the clinical manifestations, diagnosis, pathophysiological mechanisms, and treatment options for fibromyalgia patients. First, the most recent diagnostic criteria for fibromyalgia, as put forth by the American College of Rheumatology will be summarized. Clinical features, including chronic widespread pain, hyperalgesia, mood disorders, anxiety, and disturbed sleep patterns will be explored in-depth. The pathogenesis and pathophysiology of fibromyalgia involves alterations in multiple ascending and descending central nervous system pathways, as well as peripheral pathways, leading to heightened pain sensitivity. Risk factors have been studied extensively, and the most recent research focuses on various genetic influences and the contributions of stress and poor sleep. Lastly, the discussion in this article focuses on treatment options for fibromyalgia; some have been mainstay options for many years. Pharmacological agents include tricyclic antidepressants, anti-epileptic drugs, selective serotonin reuptake inhibitors, norepinephrine/serotonin reuptake inhibitors, as well as some investigational agents. The evidence behind non-pharmacologic treatments, including massage therapy, exercise, and acupuncture, are discussed.

  12. A Tabletop Persistent-Mode, Liquid-Helium-Free, 1.5-T/90-mm MgB2 “Finger” MRI Magnet for Osteoporosis Screening: Two Design Options

    PubMed Central

    Park, Dongkeun; Bascuñán, Juan; Michael, Philip C.; Iwasa, Yukikazu

    2017-01-01

    In this paper we present two design options for a tabletop liquid-helium-free, persistent-mode 1.5-T/90-mm MgB2 “finger” MRI magnet for osteoporosis screening. Both designs, one with and the other without an iron yoke, satisfy the following criteria: 1) 1.5-T center field with a 90-mm room-temperature bore for a finger to be placed at the magnet center; 2) spatial field homogeneity of <5 ppm over a 20-mm diameter of spherical volume (DSV); 3) persistent-mode operation with temporal stability of <0.1 ppm/hr; 4) liquid-helium-free operation; 5) 5-gauss fringe field radius of <50 cm from the magnet center; and 6) small and light enough for placement on an exam table. Although the magnet is designed to operate nominally at 10 K, maintained by a cryocooler, it has a 5-K temperature margin to keep its 1.5-T persistent field up to 15 K. The magnet will be immersed in a volume of solid nitrogen (SN2) that provides additional thermal mass when the cryocooler is switched off to provide a vibration-free measurement environment. The SN2 enables the magnet to maintain its persistent field over a period of time sufficient for quiescent measurement, while still limiting the magnet operating temperature to ≤15 K. We discuss first pros and cons of each design, and then further studies of our proposed MgB2 finger MRI magnet. PMID:29456437

  13. Community Options for Elders.

    ERIC Educational Resources Information Center

    Poulsen, Joyce G.

    This paper describes the Winnebago County (Wisconsin) Community Options Program, begun in January, 1982, which provides for a comprehensive assessment of all elderly persons within the target area who are at risk of becoming institutionalized. The paper focuses on the planning activities for the first year of the pilot program including community…

  14. Local modifications of magnetism and structure in FePt (001) epitaxial thin films by focused ion beam: Two-dimensional perpendicular patterns

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Albertini, F.; Nasi, L.; Casoli, F.

    Focused ion beam was utilized to locally modify magnetism and structure of L1{sub 0} FePt perpendicular thin films. As a first step, we have performed a magnetic, morphological, and structural study of completely irradiated FePt films with different Ga{sup +} doses (1x10{sup 13} -4x10{sup 16} ions/cm{sup 2}) and ion beam energy of 30 keV. For doses of 1x10{sup 14} ions/cm{sup 2} and above a complete transition from the ordered L1{sub 0} to the disordered A1 phase was found to occur, resulting in a drop of magnetic anisotropy and in the consequent moment reorientation from out-of-plane to in-plane. The lowest effectivemore » dose in disordering the structure (1x10{sup 14} ions/cm{sup 2}) was found not to affect the film morphology. Taking advantage of these results, continuous two-dimensional (2D) patterns of perpendicular magnetic structures (250 nm dots, 1 {mu}m dots, 1 {mu}m-large stripes) were produced by focused ion beam without affecting the morphology. The 2D patterns were revealed by means of magnetic force microscopy, that evidenced peculiar domain structures in the case of 1 {mu}m dots.« less

  15. Making real options really work.

    PubMed

    van Putten, Alexander B; MacMillan, Ian C

    2004-12-01

    As a way to value growth opportunities, real options have had a difficult time catching on with managers. Many CFOs believe the method ensures the overvaluation of risky projects. This concern is legitimate, but abandoning real options as a valuation model isn't the solution. Companies that rely solely on discounted cash flow (DCF) analysis underestimate the value of their projects and may fail to invest enough in uncertain but highly promising opportunities. CFOs need not--and should not--choose one approach over the other. Far from being a replacement for DCF analysis, real options are an essential complement, and a project's total value should encompass both. DCF captures a base estimate of value; real options take into account the potential for big gains. This is not to say that there aren't problems with real options. As currently applied, they focus almost exclusively on the risks associated with revenues, ignoring the risks associated with a project's costs. It's also true that option valuations almost always ignore assets that an initial investment in a subsequently abandoned project will often leave the company. In this article, the authors present a simple formula for combining DCF and option valuations that addresses these two problems. Using an integrated approach, managers will, in the long run, select better projects than their more timid competitors while keeping risk under control. Thus, they will outperform their rivals in both the product and the capital markets.

  16. Modeling of the focusing device and the elliptical neutron guide for the DN-6 diffractometer at IBR-2 reactor

    NASA Astrophysics Data System (ADS)

    Belushkin, A. V.; Manoshin, S. A.; Kozlenko, D. P.; Kichanov, S. E.

    2018-06-01

    Possible options for modernization of the neutron beam forming system of the DN-6 diffractometer for the study of crystal and magnetic structures of microsamples at high pressures are being considered. It was demonstrated that for samples with the cross-section not exceeding 5 × 5 mm2 the most efficient option would be the use of an elliptical neutron guide. It allows to deliver neutrons for large distances from the source to samples with minimal losses using, as a rule, just one neutron reflection per dimension i.e. one at a side and one at top or bottom. For the present moment due to technical difficulties of such option realization, the simplified solution was proposed. At the end of the curved neutron guide it is planned to install a vertical plane focusing 7-meter-long parabolic section. Such a modernization will increase the neutron flux at the sample by a factor 1.5-3.5 and reduce respectively the typical measurement times.

  17. Magnetic Resonance-Guided High-Intensity Focused Ultrasound (MRgHIFU) for Treatment of Symptomatic Uterine Fibroids: An Economic Analysis

    PubMed Central

    Babashov, V; Palimaka, S; Blackhouse, G; O'Reilly, D

    2015-01-01

    Background Uterine fibroids, or leiomyomas, are the most common benign tumours in women of childbearing age. Some women experience symptoms (e.g., heavy bleeding) that require aggressive forms of treatment such as uterine artery embolization (UAE), myomectomy, magnetic resonance-guided high-intensity focused ultrasound (MRgHIFU), and even hysterectomy. It is important to note that hysterectomy is not appropriate for women who desire future childbearing. Objectives The objective of this analysis was to evaluate the cost-effectiveness and budgetary impact of implementing MRgHIFU as a treatment option for symptomatic uterine fibroids in premenopausal women for whom drugs have been ineffective. Review Methods We performed an original cost-effectiveness analysis to assess the long-term costs and effects of MRgHIFU compared with hysterectomy, myomectomy, and UAE as a strategy for treating symptomatic uterine fibroids in premenopausal women aged 40 to 51 years. We explored a number of scenarios, e.g., comparing MRgHIFU with uterine-preserving procedures only, considering MRgHIFU-eligible patients only, and eliminating UAE as a treatment option. In addition, we performed a one-year budget impact analysis, using data from Ontario administrative sources. Four scenarios were explored in the budgetary impact analysis: MRgHIFU funded at 2 centres MRgHIFU funded at 2 centres and replacing only uterine-preserving procedures MRgHIFU funded at 6 centres MRgHIFU funded at 6 centres and replacing only uterine-preserving procedures Analyses were conducted from the Ontario public payer perspective. Results The base case determined that the uterine artery embolization (UAE) treatment strategy was the cost-effective option at commonly accepted willingness-to-pay values. Compared with hysterectomy, UAE was calculated as having an incremental cost-effectiveness ratio (ICER) of $46,480 per quality-adjusted life-year (QALY) gained. The MRgHIFU strategy was extendedly dominated by a

  18. The Implications of Real Options on ERP-Enabled Adoption

    ERIC Educational Resources Information Center

    Nwankpa, Joseph K.

    2012-01-01

    Current research on Enterprise Resource Planning (ERP) systems and real options focuses on valuation and justification issues that manager's face prior to project approval with existing literature attempting to demonstrate that ERP systems as technology positioning investments have option-like characteristics thus making such ERP systems…

  19. Non-invasive treatment efficacy evaluation for high-intensity focused ultrasound therapy using magnetically induced magnetoacoustic measurement

    NASA Astrophysics Data System (ADS)

    Guo, Gepu; Wang, Jiawei; Ma, Qingyu; Tu, Juan; Zhang, Dong

    2018-04-01

    Although the application of high intensity focused ultrasound (HIFU) has been demonstrated to be a non-invasive treatment technology for tumor therapy, the real-time temperature monitoring is still a key issue in the practical application. Based on the temperature-impedance relation, a fixed-point magnetically induced magnetoacoustic measurement technology of treatment efficacy evaluation for tissue thermocoagulation during HIFU therapy is developed with a sensitive indicator of critical temperature monitoring in this study. With the acoustic excitation of a focused transducer in the magnetoacoustic tomography with the magnetic induction system, the distributions of acoustic pressure, temperature, electrical conductivity, and acoustic source strength in the focal region are simulated, and the treatment time dependences of the peak amplitude and the corresponding amplitude derivative under various acoustic powers are also achieved. It is proved that the strength peak of acoustic sources is generated by tissue thermocoagulation with a sharp conductivity variation. The peak amplitude of the transducer collected magnetoacoustic signal increases accordingly along with the increase in the treatment time under a fixed acoustic power. When the temperature in the range with the radial and axial widths of about ±0.46 mm and ±2.2 mm reaches 69 °C, an obvious peak of the amplitude derivative can be achieved and used as a sensitive indicator of the critical status of treatment efficacy. The favorable results prove the feasibility of real-time non-invasive temperature monitoring and treatment efficacy evaluation for HIFU ablation using the magnetically induced magnetoacoustic measurement, and might provide a new strategy for accurate dose control during HIFU therapy.

  20. Emerging treatment options for acute bacterial skin and skin structure infections: focus on intravenous delafloxacin

    PubMed Central

    Righi, Elda; Carnelutti, Alessia; Vena, Antonio; Bassetti, Matteo

    2018-01-01

    The increase in hospitalization due to acute bacterial skin and skin structure infections (ABSSSI) caused by resistant pathogens supports the need for new treatment options. Antimicrobial options for ABSSSI that provide broad-spectrum coverage, including gram-negative pathogens and multidrug-resistant gram-positive bacteria, such as methicillin-resistant Staphylococcus aureus (MRSA), are limited. Delafloxacin is a novel fluoroquinolone available as intravenous and oral formulations and is characterized by an increased efficacy in acidic environments and activity on bacterial biofilm. Delafloxacin displays enhanced in vitro activity against MRSA, and enterococci, while maintaining efficacy against gram-negative pathogens and anaerobes. Delafloxacin has been studied for the treatment of ABSSSI and respiratory infections. Phase III studies have demonstrated noninferiority of delafloxacin compared to vancomycin, linezolid, tigecycline, and the combination of vancomycin plus aztreonam in the treatment of ABSSSI. Due to its favorable pharmacokinetic characteristics, the wide spectrum of action, and the potential for sequential therapy, delafloxacin represents a promising option in the empirical and targeted treatment of ABSSSI, both in hospital- and in community-based care. PMID:29670380

  1. Emerging treatment options for acute bacterial skin and skin structure infections: focus on intravenous delafloxacin.

    PubMed

    Righi, Elda; Carnelutti, Alessia; Vena, Antonio; Bassetti, Matteo

    2018-01-01

    The increase in hospitalization due to acute bacterial skin and skin structure infections (ABSSSI) caused by resistant pathogens supports the need for new treatment options. Antimicrobial options for ABSSSI that provide broad-spectrum coverage, including gram-negative pathogens and multidrug-resistant gram-positive bacteria, such as methicillin-resistant Staphylococcus aureus (MRSA), are limited. Delafloxacin is a novel fluoroquinolone available as intravenous and oral formulations and is characterized by an increased efficacy in acidic environments and activity on bacterial biofilm. Delafloxacin displays enhanced in vitro activity against MRSA, and enterococci, while maintaining efficacy against gram-negative pathogens and anaerobes. Delafloxacin has been studied for the treatment of ABSSSI and respiratory infections. Phase III studies have demonstrated noninferiority of delafloxacin compared to vancomycin, linezolid, tigecycline, and the combination of vancomycin plus aztreonam in the treatment of ABSSSI. Due to its favorable pharmacokinetic characteristics, the wide spectrum of action, and the potential for sequential therapy, delafloxacin represents a promising option in the empirical and targeted treatment of ABSSSI, both in hospital- and in community-based care.

  2. On Ramps: Options and Issues in Accessing the Internet.

    ERIC Educational Resources Information Center

    Bocher, Bob

    1995-01-01

    Outlines the basic options that schools and libraries have for accessing the Internet, focusing on four models: direct connection; dial access using SLIP/PPP (Serial Line Internet Protocol/Point-to-Point Protocol); dial-up using terminal emulation mode; and dial access through commercial online services. Discusses access option issues such as…

  3. Special Schools and Other Options for Gifted STEM Students

    ERIC Educational Resources Information Center

    Olszewski-Kubilius, Paula

    2010-01-01

    Special schools focused on the Science, Technology, Engineering, and Mathematics (STEM) disciplines are one of the best options for gifted students with talent and interest in these areas. Such schools offer benefits, such as unique opportunities for research and mentoring, that other options cannot. In this article, I compare the advantages and…

  4. Financial options methodology for analyzing investments in new technology

    NASA Technical Reports Server (NTRS)

    Wenning, B. D.

    1995-01-01

    The evaluation of investments in longer term research and development in emerging technologies, because of the nature of such subjects, must address inherent uncertainties. Most notably, future cash flow forecasts include substantial uncertainties. Conventional present value methodology, when applied to emerging technologies severely penalizes cash flow forecasts, and strategic investment opportunities are at risk of being neglected. Use of options evaluation methodology adapted from the financial arena has been introduced as having applicability in such technology evaluations. Indeed, characteristics of superconducting magnetic energy storage technology suggest that it is a candidate for the use of options methodology when investment decisions are being contemplated.

  5. Experiments and Simulations on Magnetically Driven Implosions in High Repetition Rate Dense Plasma Focus

    NASA Astrophysics Data System (ADS)

    Caballero Bendixsen, Luis; Bott-Suzuki, Simon; Cordaro, Samuel; Krishnan, Mahadevan; Chapman, Stephen; Coleman, Phil; Chittenden, Jeremy

    2015-11-01

    Results will be shown on coordinated experiments and MHD simulations on magnetically driven implosions, with an emphasis on current diffusion and heat transport. Experiments are run at a Mather-type dense plasma focus (DPF-3, Vc: 20 kV, Ip: 480 kA, E: 5.8 kJ). Typical experiments are run at 300 kA and 0.33 Hz repetition rate with different gas loads (Ar, Ne, and He) at pressures of ~ 1-3 Torr, usually gathering 1000 shots per day. Simulations are run at a 96-core HP blade server cluster using 3GHz processors with 4GB RAM per node.Preliminary results show axial and radial phase plasma sheath velocity of ~ 1x105 m/s. These are in agreement with the snow-plough model of DPFs. Peak magnetic field of ~ 1 Tesla in the radial compression phase are measured. Electron densities on the order of 1018 cm-3 anticipated. Comparison between 2D and 3D models with empirical results show a good agreement in the axial and radial phase.

  6. Universal main magnetic focus ion source for production of highly charged ions

    NASA Astrophysics Data System (ADS)

    Ovsyannikov, V. P.; Nefiodov, A. V.; Levin, A. A.

    2017-10-01

    A novel room-temperature compact ion source has been developed for the efficient production of atomic ions by means of an electron beam with energy Ee and current density je controllable within wide ranges (100 eV ≲Ee ≲ 60 keV, 10 A/cm2 ≲je ≲ 20 kA/cm2). In the first experiments, the X-ray emission of Ir64+ ions has been measured. Based on a combination of two different techniques, the device can operate both as conventional Electron Beam Ion Source/Trap and novel Main Magnetic Focus Ion Source. The tunable electron-optical system allows for realizing laminar and turbulent electron flows in a single experimental setup. The device is intended primarily for fundamental and applied research at standard university laboratories.

  7. Assessment Of The Stirling Power Option for Space Science Applications

    NASA Technical Reports Server (NTRS)

    Schreiber, Jeffrey G.

    2000-01-01

    Free-piston Stirling technology efforts in the past typically were intended to address power needs in the multi-kilowatt range. The Stirling power option was attractive primarily because of the high conversion efficiency and potential for long life. In recent years, several technology efforts have focused on the free-piston Stirling power d convertor for space power applications, however the more recent efforts are intended to provide power at levels far below one kilowatt. Through a variety of projects funded by both NASA and DOE, the free-piston Stirling convertor technology has successfully demonstrated high efficiency and long life. Other areas of concern, such as control of multi-convertor systems, and vibration reduction have also been addressed. Efforts are being initiated to address issues such as electro-magnetic interference (EMI), radiation tolerance of organic materials, and the ability to operate through launch loads and survive with integrity. The status of the technology in these areas will be briefly discussed in this paper.

  8. Low-Cost Magnetic Stirrer from Recycled Computer Parts with Optional Hot Plate

    ERIC Educational Resources Information Center

    Guidote, Armando M., Jr.; Pacot, Giselle Mae M.; Cabacungan, Paul M.

    2015-01-01

    Magnetic stirrers and hot plates are key components of science laboratories. However, these are not readily available in many developing countries due to their high cost. This article describes the design of a low-cost magnetic stirrer with hot plate from recycled materials. Some of the materials used are neodymium magnets and CPU fans from…

  9. Self-focusing and defocusing of Gaussian laser beams in collisional underdense magnetized plasmas with considering the nonlinear ohmic heating and ponderomotive force effects

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ettehadi Abari, Mehdi; Sedaghat, Mahsa; Shokri, Babak, E-mail: b-shokri@sbu.ac.ir

    2015-10-15

    The propagation characteristics of a Gaussian laser beam in collisional magnetized plasma are investigated by considering the ponderomotive and ohmic heating nonlinearities. Here, by taking into account the effect of the external magnetic field, the second order differential equation of the dimensionless beam width parameter is solved numerically. Furthermore, the nonlinear dielectric permittivity of the mentioned plasma medium in the paraxial approximation and its dependence on the propagation characteristics of the Gaussian laser pulse is obtained, and its variation in terms of the dimensionless plasma length is analyzed at different initial normalized plasma and cyclotron frequencies. The results show thatmore » the dimensionless beam width parameter is strongly affected by the initial plasma frequency, magnetic strength, and laser pulse intensity. Furthermore, it is found that there exists a certain intensity value below which the laser pulse tends to self focus, while the beam diverges above of this value. In addition, the results confirm that, by increasing the plasma and cyclotron frequencies (plasma density and magnetic strength), the self-focusing effect can occur intensively.« less

  10. Usage of Magnetic Resonance Guided Focused Ultrasound Surgery (mrgfus) in Oncology

    NASA Astrophysics Data System (ADS)

    Bauer, Yair

    2011-09-01

    Magnetic resonance guided focused ultrasound surgery (MRgFUS) is a non-invasive incision-less surgical approach which limits the tissue destruction to the targeted tumor. Acoustic energy penetrates through intact skin and through the tissues surrounding the tumor without causing any significant bio-effects. Energy deposition takes place mainly at the focal spot where heat induced thermal coagulation of the targeted tissue is accomplished. Real time targeting and image guidance is provided by MRI tumor margin definition and real time thermometry provides closed loop feedback control of energy deposition. The patient lies in the MRI scanner throughout the treatment planning and treatment, and the physician conducts the treatment from the MRgFUS workstation in the adjacent MR control room. The ExAblate system for MRgFUS is commercially available in many countries for treatment of uterine fibroids. The system has also received CE and KFDA approval for pain palliation of bone metastases, and research of other oncologic applications is underway.

  11. Investigation of shape, position, and permeability of shielding material in quadruple butterfly coil for focused transcranial magnetic stimulation

    NASA Astrophysics Data System (ADS)

    Rastogi, Priyam; Zhang, Bowen; Tang, Yalun; Lee, Erik G.; Hadimani, Ravi L.; Jiles, David C.

    2018-05-01

    Transcranial magnetic stimulation has been gaining popularity in the therapy for several neurological disorders. A time-varying magnetic field is used to generate electric field in the brain. As the development of TMS methods takes place, emphasis on the coil design increases in order to improve focal stimulation. Ideally reduction of stimulation of neighboring regions of the target area is desired. This study, focused on the improvement of the focality of the Quadruple Butterfly Coil (QBC) with supplemental use of different passive shields. Parameters such as shape, position and permeability of the shields have been explored to improve the focus of stimulation. Results have been obtained with the help of computer modelling of a MRI derived heterogeneous head model over the vertex position and the dorsolateral prefrontal cortex position using a finite element tool. Variables such as maximum electric field induced on the grey matter and scalp, volume and area of stimulation above half of the maximum value of electric field on the grey matter, and ratio of the maximum electric field in the brain versus the scalp have been investigated.

  12. Alternating phase focused linacs

    DOEpatents

    Swenson, Donald A.

    1980-01-01

    A heavy particle linear accelerator employing rf fields for transverse and ongitudinal focusing as well as acceleration. Drift tube length and gap positions in a standing wave drift tube loaded structure are arranged so that particles are subject to acceleration and succession of focusing and defocusing forces which contain the beam without additional magnetic or electric focusing fields.

  13. Solar pumped laser technology options for space power transmission

    NASA Technical Reports Server (NTRS)

    Conway, E. J.

    1986-01-01

    An overview of long-range options for in-space laser power transmission is presented. The focus is on the new technology and research status of solar-pumped lasers and their solar concentration needs. The laser options include gas photodissociation lasers, optically-pumped solid-state lasers, and blackbody-pumped transfer lasers. The paper concludes with a summary of current research thrusts.

  14. Reviving Magnet Schools: Strengthening a Successful Choice Option. A Research Brief

    ERIC Educational Resources Information Center

    Siegel-Hawley, Genevieve; Frankenberg, Erica

    2012-01-01

    Magnet schools make up the largest system of choice in the U.S. They were originally conceived to accomplish the twin goals of innovation and integration. Over the years, however, the integrative mission of magnet programs has somewhat receded, particularly during the second Bush Administration. Meanwhile, political and financial support has…

  15. Treatment of central sensitization in patients with 'unexplained' chronic pain: what options do we have?

    PubMed

    Nijs, Jo; Meeus, Mira; Van Oosterwijck, Jessica; Roussel, Nathalie; De Kooning, Margot; Ickmans, Kelly; Matic, Milica

    2011-05-01

    Central sensitization accounts for chronic 'unexplained' pain in a wide variety of disorders, including chronic whiplash-associated disorders, temporomandibular disorders, chronic low back pain, osteoarthritis, fibromyalgia, chronic fatigue syndrome and chronic tension-type headache among others. Given the increasing evidence supporting the clinical significance of central sensitization in those with unexplained chronic pain, the awareness is growing that central sensitization should be a treatment target in these patients. This article provides an overview of the treatment options available for desensitizing the CNS in patients with chronic pain due to central sensitization. It focuses on those strategies that specifically target pathophysiological mechanisms known to be involved in central sensitization. In addition, pharmacological options, rehabilitation and neurotechnology options are discussed. Acetaminophen, serotonin-reuptake inhibitor drugs, selective and balanced serototin and norepinephrine-reuptake inhibitor drugs, the serotonin precursor tryptophan, opioids, N-methyl-d-aspartate (NMDA)-receptor antagonists, calcium-channel alpha(2)delta (a2δ) ligands, transcranial magnetic stimulation, transcutaneous electric nerve stimulation (TENS), manual therapy and stress management each target central pain processing mechanisms in animals that - theoretically - desensitize the CNS in humans. To provide a comprehensive treatment for 'unexplained' chronic pain disorders characterized by central sensitization, it is advocated to combine the best evidence available with treatment modalities known to target central sensitization. © 2011 Informa UK, Ltd

  16. 48 CFR 552.217-71 - Notice Regarding Option(s).

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 4 2010-10-01 2010-10-01 false Notice Regarding Option(s... Notice Regarding Option(s). As prescribed in 517.208(b), insert the following provision: Notice Regarding Option(s) (NOV 1992) The General Services Administration (GSA) has included an option to [Insert...

  17. Magnetic suspension and balance system advanced study

    NASA Technical Reports Server (NTRS)

    Boom, R. W.; Eyssa, Y. M.; Mcintosh, G. E.; Abdelsalam, M. K.

    1985-01-01

    An improved compact design for a superconducting magnetic suspension and balance system for an 8 ft. x 8 ft. transonic wind tunnel is developed. The original design of an MSBS in NASA Cr-3802 utilized 14 external superconductive coils and a superconductive solenoid in the airplane test model suspended in a wind tunnel. The improvements are in the following areas: test model solenoid options, dynamic force limits on the model, magnet cooling options, structure and cryogenic designs, power supply specifications, and cost and performance evaluations. The improvements are: MSBS cost reduction of 28%, weight; reduction of 43%, magnet system ampere-meter reduction of 38%, helium liquifier capacity reduction by 33%, magnet system stored energy reduction by 55%, AC loss to liquid helium reduced by 76%, system power supply reduced by 68%, test coil pole strength increased by 19%, wing magnetization increased by 40%, and control frequency limit increased by 200% from 10 Hz to 30 Hz. The improvements are due to: magnetic holmium coil forms in the test model, better rare earth permanent magnets in the wings, fiberglass-epoxy structure replacing stainless steel, better coil configuration, and new saddle roll coil design.

  18. Flexibility and Project Value: Interactions and Multiple Real Options

    NASA Astrophysics Data System (ADS)

    Čulík, Miroslav

    2010-06-01

    This paper is focused on a project valuation with embedded portfolio of real options including their interactions. Valuation is based on the criterion of Net Present Value on the simulation basis. Portfolio includes selected types of European-type real options: option to expand, contract, abandon and temporarily shut down and restart a project. Due to the fact, that in reality most of the managerial flexibility takes the form of portfolio of real options, selected types of options are valued not only individually, but also in combination. The paper is structured as follows: first, diffusion models for forecasting of output prices and variable costs are derived. Second, project value is estimated on the assumption, that no real options are present. Next, project value is calculated with the presence of selected European-type options; these options and their impact on project value are valued first in isolation and consequently in different combinations. Moreover, intrinsic value evolution of given real options with respect to the time of exercising is analysed. In the end, results are presented graphically; selected statistics and risk measures (Value at Risk, Expected Shortfall) of the NPV's distributions are calculated and commented.

  19. Financial options methodology for analyzing investments in new technology

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wenning, B.D.

    1994-12-31

    The evaluation of investments in longer term research and development in emerging technologies, because of the nature of such subjects, must address inherent uncertainties. Most notably, future cash flow forecasts include substantial uncertainties. Conventional present value methodology, when applied to emerging technologies severely penalizes cash flow forecasts, and strategic investment opportunities are at risk of being neglected. Use of options valuation methodology adapted from the financial arena has been introduced as having applicability in such technology evaluations. Indeed, characteristics of superconducting magnetic energy storage technology suggest that it is a candidate for the use of options methodology when investment decisionsmore » are being contemplated.« less

  20. Magnetic Resonance Imaging-Guided Focused Ultrasound Surgery for the Treatment of Symptomatic Uterine Fibroids.

    PubMed

    Geraci, Laura; Napoli, Alessandro; Catalano, Carlo; Midiri, Massimo; Gagliardo, Cesare

    2017-01-01

    Uterine fibroids, the most common benign tumor in women of childbearing age, may cause symptoms including pelvic pain, menorrhagia, dysmenorrhea, pressure, urinary symptoms, and infertility. Various approaches are available to treat symptomatic uterine fibroids. Magnetic Resonance-guided Focused Ultrasound Surgery (MRgFUS) represents a recently introduced noninvasive safe and effective technique that can be performed without general anesthesia, in an outpatient setting. We review the principles of MRgFUS, describing patient selection criteria for the treatments performed at our center and we present a series of five selected patients with symptomatic uterine fibroids treated with this not yet widely known technique, showing its efficacy in symptom improvement and fibroid volume reduction.

  1. Electron Gun For Multiple Beam Klystron Using Magnetic Focusing

    DOEpatents

    Ives, R. Lawrence; Miram, George; Krasnykh, Anatoly

    2004-07-27

    An RF device comprising a plurality of drift tubes, each drift tube having a plurality of gaps defining resonant cavities, is immersed in an axial magnetic field. RF energy is introduced at an input RF port at one of these resonant cavities and collected at an output RF port at a different RF cavity. A plurality of electron beams passes through these drift tubes, and each electron beam has an individual magnetic shaping applied which enables confined beam transport through the drift tubes.

  2. Magnetic resonance-guided high-intensity focused ultrasound (MR-HIFU) ablation of liver tumours.

    PubMed

    Wijlemans, J W; Bartels, L W; Deckers, R; Ries, M; Mali, W P Th M; Moonen, C T W; van den Bosch, M A A J

    2012-09-28

    Recent decades have seen a paradigm shift in the treatment of liver tumours from invasive surgical procedures to minimally invasive image-guided ablation techniques. Magnetic resonance-guided high-intensity focused ultrasound (MR-HIFU) is a novel, completely non-invasive ablation technique that has the potential to change the field of liver tumour ablation. The image guidance, using MR imaging and MR temperature mapping, provides excellent planning images and real-time temperature information during the ablation procedure. However, before clinical implementation of MR-HIFU for liver tumour ablation is feasible, several organ-specific challenges have to be addressed. In this review we discuss the MR-HIFU ablation technique, the liver-specific challenges for MR-HIFU tumour ablation, and the proposed solutions for clinical translation.

  3. Magnetic resonance-guided high-intensity focused ultrasound (MR-HIFU) ablation of liver tumours

    PubMed Central

    Bartels, L.W.; Deckers, R.; Ries, M.; Mali, W.P.Th.M.; Moonen, C.T.W.; van den Bosch, M.A.A.J.

    2012-01-01

    Abstract Recent decades have seen a paradigm shift in the treatment of liver tumours from invasive surgical procedures to minimally invasive image-guided ablation techniques. Magnetic resonance-guided high-intensity focused ultrasound (MR-HIFU) is a novel, completely non-invasive ablation technique that has the potential to change the field of liver tumour ablation. The image guidance, using MR imaging and MR temperature mapping, provides excellent planning images and real-time temperature information during the ablation procedure. However, before clinical implementation of MR-HIFU for liver tumour ablation is feasible, several organ-specific challenges have to be addressed. In this review we discuss the MR-HIFU ablation technique, the liver-specific challenges for MR-HIFU tumour ablation, and the proposed solutions for clinical translation. PMID:23022541

  4. ICU nurses and physicians dialogue regarding patients clinical status and care options-a focus group study.

    PubMed

    Kvande, Monica; Lykkeslet, Else; Storli, Sissel Lisa

    2017-12-01

    Nurses and physicians work side-by-side in the intensive care unit (ICU). Effective exchanges of patient information are essential to safe patient care in the ICU. Nurses often rate nurse-physician communication lower than physicians and report that it is difficult to speak up, that disagreements are not resolved and that their input is not well received. Therefore, this study explored nurses' dialogue with physicians regarding patients' clinical status and the prerequisites for effective and accurate exchanges of information. We adopted a qualitative approach, conducting three focus group discussions with five to six nurses and physicians each (14 total). Two themes emerged. The first theme highlighted nurses' contributions to dialogues with physicians; nurses' ongoing observations of patients were essential to patient care discussions. The second theme addressed the prerequisites of accurate and effective dialogue regarding care options, comprising three subthemes: nurses' ability to speak up and present clinical changes, establishment of shared goal and clinical understanding, and open dialogue and willingness to listen to each other. Nurses should understand their essential role in conducting ongoing observations of patients and their right to be included in care-related decision-making processes. Physicians should be willing to listen to and include nurses' clinical observations and concerns.

  5. Pawnee Nation Energy Option Analyses

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Matlock, M.; Kersey, K.; Riding In, C.

    2009-07-21

    Pawnee Nation of Oklahoma Energy Option Analyses In 2003, the Pawnee Nation leadership identified the need for the tribe to comprehensively address its energy issues. During a strategic energy planning workshop a general framework was laid out and the Pawnee Nation Energy Task Force was created to work toward further development of the tribe’s energy vision. The overarching goals of the “first steps” project were to identify the most appropriate focus for its strategic energy initiatives going forward, and to provide information necessary to take the next steps in pursuit of the “best fit” energy options. Description of Activities Performedmore » The research team reviewed existing data pertaining to the availability of biomass (focusing on woody biomass, agricultural biomass/bio-energy crops, and methane capture), solar, wind and hydropower resources on the Pawnee-owned lands. Using these data, combined with assumptions about costs and revenue streams, the research team performed preliminary feasibility assessments for each resource category. The research team also reviewed available funding resources and made recommendations to Pawnee Nation highlighting those resources with the greatest potential for financially-viable development, both in the near-term and over a longer time horizon. Findings and Recommendations Due to a lack of financial incentives for renewable energy, particularly at the state level, combined mediocre renewable energy resources, renewable energy development opportunities are limited for Pawnee Nation. However, near-term potential exists for development of solar hot water at the gym, and an exterior wood-fired boiler system at the tribe’s main administrative building. Pawnee Nation should also explore options for developing LFGTE resources in collaboration with the City of Pawnee. Significant potential may also exist for development of bio-energy resources within the next decade. Pawnee Nation representatives should closely

  6. Students' Perceptions of a Program for Exploring Postsecondary Options

    ERIC Educational Resources Information Center

    Deemer, Sandra A.; Ostrowski, Melissa

    2010-01-01

    This paper focuses on findings from the first wave of a longitudinal study investigating high school students' perceptions and behaviors as they engage in a graduation project focused on exploring postsecondary options. Students (n=157) completed surveys regarding their achievement goals, sense of belongingness and career exploration endeavors. A…

  7. Focusing Electron Beams at SLAC.

    ERIC Educational Resources Information Center

    Taylor, Richard L.

    1993-01-01

    Describes the development of a set of magnets that focus high-energy electron and positron beams causing them to collide, annihilate each other, and generate new particles. Explains how dipoles bend the beam, how quadrupoles focus the beam, how the focal length is calculated, and the superconducting final focus. (MDH)

  8. The effect of patterning options on embedded memory cells in logic technologies at iN10 and iN7

    NASA Astrophysics Data System (ADS)

    Appeltans, Raf; Weckx, Pieter; Raghavan, Praveen; Kim, Ryoung-Han; Kar, Gouri Sankar; Furnémont, Arnaud; Van der Perre, Liesbet; Dehaene, Wim

    2017-03-01

    Static Random Access Memory (SRAM) cells are used together with logic standard cells as the benchmark to develop the process flow for new logic technologies. In order to achieve successful integration of Spin-Transfer Torque Magnetic Random Access Memory (STT-MRAM) as area efficient higher level embedded cache, it also needs to be included as a benchmark. The simple cell structure of STT-MRAM brings extra patterning challenges to achieve high density. The two memory types are compared in terms of minimum area and critical design rules in both the iN10 and iN7 node, with an extra focus on patterning options in iN7. Both the use of Self-Aligned Quadruple Patterning (SAQP) mandrel and spacer engineering, as well as multi-level via's are explored. These patterning options result in large area gains for the STT-MRAM cell and moreover determine which cell variant is the smallest.

  9. ExAblate magnetic resonance-guided focused ultrasound system in multiple body applications.

    PubMed

    Dick, E A; Gedroyc, W M W

    2010-09-01

    Focused ultrasound surgery (FUS) is a completely noninvasive method of thermally destroying a target tissue while sparing adjacent tissues and organs. Treatment is relatively painless and can be carried out under conscious sedation on an out-patient basis. The combination of magnetic resonance guidance with FUS (MRgFUS) provides the ability to plan and monitor treatments in near real-time, further increasing the safety profile of MRgFUS. This technology provides a very personalized treatment, adjusted to the individual patient anatomy, pathology and treatment response, hence it meets the needs of patients, as well as of physicians. MRgFUS has been used extensively in the successful treatment of uterine fibroids, and has been shown to be an effective treatment in the breast and in bone metastases in smaller scale studies. It shows great potential in the treatment of prostate and liver tumors, as well as in the brain and facet joints.

  10. Magnetic Resonance Guided Focused Ultrasound Surgery: Part 2 – A Review of Current and Future Applications

    PubMed Central

    Medel, Ricky; Monteith, Stephen J.; Elias, W. Jeffrey; Eames, Matthew; Snell, John; Sheehan, Jason P.; Wintermark, Max; Jolesz, Ferenc A.; Kassell, Neal F.

    2014-01-01

    Magnetic Resonance guided Focused Ultrasound Surgery (MRgFUS) represents a novel combination of technologies that is actively being realized as a non-invasive therapeutic tool for a myriad of conditions. These applications are reviewed with a focus on neurological utilization. A combined search of Pubmed and Medline was performed to identify the key events and current status of MRgFUS, with a focus on neurological applications. MRgFUS signifies a potentially ideal device for the treatment of neurological diseases. As it is nearly real-time, it allows monitored provision of treatment location and energy deposition, is noninvasive, thereby limiting or eliminating disruption of normal tissue, provides focal delivery of therapeutic agents, enhances radiation delivery, and permits modulation of neural function. Multiple clinical applications are currently in clinical use and many more are under active preclinical investigation. The therapeutic potential of MRgFUS is expanding rapidly. Although clinically in its infancy, preclinical and early phase I clinical trials in neurosurgery suggest a promising future for MRgFUS. Further investigation is necessary to define its true potential and impact. PMID:22791029

  11. Chapter 13, Policy options: North America

    Treesearch

    Jane Barr; James Dobrowolski; John Campbell; Philippe Le Prestre; Lori Lynch; Marc Sydnor; Robert Adler; Jose Etcheverry; Alexander Kenny; Catherine Hallmich; Jim Lazar; Russell M. Meyer; Robin Newmark; Janet Peace; Julie A. Suhr Pierce; Stephen Yamasaki

    2012-01-01

    As previously indicated, GEO-5 shifts the GEO focus from identifying environmental problems to identifying solutions that governments can then prioritize. This chapter provides examples of a number of policy options and market mechanisms that have shown some success in improving environmental conditions in North America. They are organized by priority environmental...

  12. Wiggler plane focusing in a linear free electron laser

    DOEpatents

    Scharlemann, Ernst T.

    1988-01-01

    Free electron laser apparatus that provides a magnetic centering force to turn or focus a non-axial electron toward the longitudinal axis as desired. The focusing effect is provided by wiggler magnet pole faces that are approximately parabolically shaped.

  13. Space Civil Engineering option - A progress report

    NASA Technical Reports Server (NTRS)

    Criswell, Marvin E.; Sadeh, Willy Z.

    1992-01-01

    Space Civil Engineering is an emerging engineering discipline that focuses on extending and expanding Civil Engineering to the development, operation, and maintenance of infrastructures on celestial bodies. Space Civil Engineering is presently being developed as a new discipline within the Department of Civil Engineering at Colorado State University and with support of the NASA Space Grant College Program. Academic programs geared toward creating Space Civil Engineering Options at both undergraduate and graduate levels are being formulated. Basic ideas and concepts and the current status of the curriculum in the Space Civil Engineering Option primarily at the undergraduate level are presented.

  14. A discontinuous Galerkin method for two-dimensional PDE models of Asian options

    NASA Astrophysics Data System (ADS)

    Hozman, J.; Tichý, T.; Cvejnová, D.

    2016-06-01

    In our previous research we have focused on the problem of plain vanilla option valuation using discontinuous Galerkin method for numerical PDE solution. Here we extend a simple one-dimensional problem into two-dimensional one and design a scheme for valuation of Asian options, i.e. options with payoff depending on the average of prices collected over prespecified horizon. The algorithm is based on the approach combining the advantages of the finite element methods together with the piecewise polynomial generally discontinuous approximations. Finally, an illustrative example using DAX option market data is provided.

  15. Indications and interventional options for non-resectable tracheal stenosis

    PubMed Central

    Bacon, Jenny Louise; Patterson, Caroline Marie

    2014-01-01

    Non-specific presentation and normal examination findings in early disease often result in tracheal obstruction being overlooked as a diagnosis until patients present acutely. Once diagnosed, surgical options should be considered, but often patient co-morbidity necessitates other interventional options. Non-resectable tracheal stenosis can be successfully managed by interventional bronchoscopy, with therapeutic options including airway dilatation, local tissue destruction and airway stenting. There are common aspects to the management of tracheal obstruction, tracheomalacia and tracheal fistulae. This paper reviews the pathogenesis, presentation, investigation and management of tracheal disease, with a focus on tracheal obstruction and the role of endotracheal intervention in management. PMID:24624290

  16. Deep magnetic capture of magnetically loaded cells for spatially targeted therapeutics.

    PubMed

    Huang, Zheyong; Pei, Ning; Wang, Yanyan; Xie, Xinxing; Sun, Aijun; Shen, Li; Zhang, Shuning; Liu, Xuebo; Zou, Yunzeng; Qian, Juying; Ge, Junbo

    2010-03-01

    Magnetic targeting has recently demonstrated potential in promoting magnetically loaded cell delivery to target lesion, but its application is limited by magnetic attenuation. For deep magnetic capture of cells for spatial targeting therapeutics, we designed a magnetic pole, in which the magnetic field density can be focused at a distance from the pole. As flowing through a tube served as a model of blood vessels, the magnetically loaded mesenchymal stem cells (MagMSCs) were highly enriched at the site distance from the magnetic pole. The cell capture efficiency was positively influenced by the magnetic flux density, and inversely influenced by the flow velocity, and well-fitted with the deductive value by theoretical considerations. It appeared to us that the spatially-focused property of the magnetic apparatus promises a new deep targeting strategy to promote homing and engraftment for cellular therapy. Copyright (c) 2009 Elsevier Ltd. All rights reserved.

  17. Wiggler plane focusing in a linear free electron laser

    DOEpatents

    Scharlemann, E.T.

    1985-11-21

    This disclosure describes a free electron laser apparatus that provides a magnetic centering force to turn or focus a non-axial electron toward the longitudinal axis as desired. The focusing effect is provided by wiggler magnet pole faces that are approximately parabolically shaped.

  18. A review of repetitive transcranial magnetic stimulation for adolescents with treatment-resistant depression.

    PubMed

    Magavi, Leela R; Reti, Irving M; Vasa, Roma A

    2017-04-01

    This review examines the efficacy and safety of repetitive transcranial magnetic stimulation (rTMS) as a treatment for treatment-resistant depression in adolescents. A systematic review of six databases was conducted. Ten multi-subject trials, all uncontrolled, and five case reports met inclusion criteria. Twelve studies focused on treatment efficacy, whereas three studies focused exclusively on adverse events. All efficacy studies focused on adolescents only; 10 of these studies indicated that rTMS may demonstrate some benefit. Improvement within 2-8 weeks was reported in most studies, with a few studies indicating potential long-term benefits. A variety of adverse events occurred including scalp pain, which was the most common, as well as seizures. Controlled studies of rTMS are warranted to further examine whether this treatment is a potential option for adolescents with treatment-resistant depression.

  19. Renal ablation using magnetic resonance-guided high intensity focused ultrasound: Magnetic resonance imaging and histopathology assessment.

    PubMed

    Saeed, Maythem; Krug, Roland; Do, Loi; Hetts, Steven W; Wilson, Mark W

    2016-03-28

    To use magnetic resonance-guided high intensity focused ultrasound (MRg-HIFU), magnetic resonance imaging (MRI) and histopathology for noninvasively ablating, quantifying and characterizing ablated renal tissue. Six anesthetized/mechanically-ventilated pigs underwent single/double renal sonication (n = 24) using a 3T-MRg-HIFU (1.1 MHz frequency and 3000J-4400J energies). T2-weighted fast spin echo (T2-W), perfusion saturation recovery gradient echo and contrast enhanced (CE) T1-weighted (T1-W) sequences were used for treatment planning, temperature monitoring, lesion visualization, characterization and quantification, respectively. Histopathology was conducted in excised kidneys to quantify and characterize cellular and vascular changes. Paired Student's t-test was used and a P-value < 0.05 was considered statistically significant. Ablated renal parenchyma could not be differentiated from normal parenchyma on T2-W or non-CE T1-W sequences. Ablated renal lesions were visible as hypoenhanced regions on perfusion and CE T1-W MRI sequences, suggesting perfusion deficits and necrosis. Volumes of ablated parenchyma on CE T1-W images in vivo (0.12-0.36 cm(3) for single sonication 3000J, 0.50-0.84 cm(3), for double 3000J, 0.75-0.78 cm(3) for single 4400J and 0.12-2.65 cm(3) for double 4400J) and at postmortem (0.23-0.52 cm(3), 0.25-0.82 cm(3), 0.45-0.68 cm(3) and 0.29-1.80 cm(3), respectively) were comparable. The ablated volumes on 3000J and 4400J double sonication were significantly larger than single (P < 0.01), thus, the volume and depth of ablated tissue depends on the applied energy and number of sonication. Macroscopic and microscopic examinations confirmed the locations and presence of coagulation necrosis, vascular damage and interstitial hemorrhage, respectively. Contrast enhanced MRI provides assessment of MRg-HIFU renal ablation. Histopathology demonstrated coagulation necrosis, vascular damage and confirmed the volume of damage seen on MRI.

  20. Larp Nb3Sn Quadrupole Magnets for the Lhc Luminosity Upgrade

    NASA Astrophysics Data System (ADS)

    Ferracin, P.

    2010-04-01

    The US LHC Accelerator Research Program (LARP) is a collaboration between four US laboratories (BNL, FNAL, LBNL, and SLAC) aimed at contributing to the commissioning and operation of the LHC and conducting R&D on its luminosity upgrade. Within LARP, the Magnet Program's main goal is to demonstrate that Nb3Sn superconducting magnets are a viable option for a future upgrade of the LHC Interaction Regions. Over the past four years, LARP has successfully fabricated and tested several R&D magnets: 1) the subscale quadrupole magnet SQ, to perform technology studies with 300 mm long racetrack coils, 2) the technology quadrupole TQ, to investigate support structure behavior with 1 m long cos 2θ coils, and 3) the long racetrack magnet LR, to test 3.6 m long racetrack coils. The next milestone consists in the fabrication and test of the 3.7 m long quadrupole magnet LQ, with the goal of demonstrating that Nb3Sn technology is mature for use in high energy accelerators. After an overview of design features and test result of the LARP magnets fabricated so far, this paper focuses on the status of the fabrication of LQ: we describe the production of the 3.4 m long cos 2θ coils, and the of the qualification support structure. Finally, the status of the development of the next 1 m long model HQ, conceived to explore stress and field limits of Nb3Sn superconducting, magnets, is presented.

  1. 20 CFR 416.2035 - Optional supplementation: Additional State options.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 20 Employees' Benefits 2 2010-04-01 2010-04-01 false Optional supplementation: Additional State options. 416.2035 Section 416.2035 Employees' Benefits SOCIAL SECURITY ADMINISTRATION SUPPLEMENTAL... § 416.2035 Optional supplementation: Additional State options. (a) Residency requirement. A State or...

  2. Cyanobacterial Treatment Options: Permanganate and Powdered Activated Carbon

    EPA Science Inventory

    This presentation will begin with a brief overview of drinking water treatment options for cyanobacteria and their toxins. The treatment discussion will focus on the impacts of permanganate addition to suspensions of toxin-producing Microcystis aeruginosa, followed by powdered ac...

  3. Comparison between three option, four option and five option multiple choice question tests for quality parameters: A randomized study.

    PubMed

    Vegada, Bhavisha; Shukla, Apexa; Khilnani, Ajeetkumar; Charan, Jaykaran; Desai, Chetna

    2016-01-01

    Most of the academic teachers use four or five options per item of multiple choice question (MCQ) test as formative and summative assessment. Optimal number of options in MCQ item is a matter of considerable debate among academic teachers of various educational fields. There is a scarcity of the published literature regarding the optimum number of option in each item of MCQ in the field of medical education. To compare three options, four options, and five options MCQs test for the quality parameters - reliability, validity, item analysis, distracter analysis, and time analysis. Participants were 3 rd semester M.B.B.S. students. Students were divided randomly into three groups. Each group was given one set of MCQ test out of three options, four options, and five option randomly. Following the marking of the multiple choice tests, the participants' option selections were analyzed and comparisons were conducted of the mean marks, mean time, validity, reliability and facility value, discrimination index, point biserial value, distracter analysis of three different option formats. Students score more ( P = 0.000) and took less time ( P = 0.009) for the completion of three options as compared to four options and five options groups. Facility value was more ( P = 0.004) in three options group as compared to four and five options groups. There was no significant difference between three groups for the validity, reliability, and item discrimination. Nonfunctioning distracters were more in the four and five options group as compared to three option group. Assessment based on three option MCQs is can be preferred over four option and five option MCQs.

  4. Correlation of the neutron yield from the plasma focus upon variations in the magnetic field energy of the discharge circuit

    NASA Astrophysics Data System (ADS)

    Ablesimov, V. E.; Dolin, Yu. N.; Kalinychev, A. E.; Tsibikov, Z. S.

    2017-10-01

    The relation between neutron yield Y and magnetic field energy variations Δ W in the discharge circuit has been studied for a Mather-type plasma-focus camera. The activation technique (activation of silver isotopes) has been used to measure the integral yield of DD neutrons from the source. The time dependence of the neutron yield has been recorded by scintillation detectors. For the device used in the investigations, the neutron yield exhibits a linear dependence on variations in the magnetic field energy Δ W in the discharge circuit at the instant of neutron generation. It is also found that this dependence is related to the initial deuteron pressure in the discharge chamber.

  5. [Anal fissure of cryptoglandular origin. Therapeutic options].

    PubMed

    Casal, Enrique; de San Ildefonso, Alberto; Sánchez, Juan; Facal, Cristina; Pampin, José

    2005-12-01

    Anal fistula is a frequent condition. The most commonly accepted origin is infectious. The most widely used classification is based on cryptoglandular theory and on the position of the fistulous tract in relation to the anal sphincter. Physical examination will help to identify the type of fistula and allow its treatment to be planned. The most widely used complementary tests are endoanal ultrasound and magnetic resonance imaging. We review the various therapeutic options and their results, especially fistulotomy, endorectal advancement flap, use of sedal, anodermal advancement flap, sphincterorrhaphy with sphincter repair, and fibrin glue.

  6. Magnetic resonance-guided focused ultrasound surgery for treatment of painful osseous metastases

    NASA Astrophysics Data System (ADS)

    Hurwitz, Mark; Machtinger, Ronit; Fennessy, Fiona

    2011-03-01

    Magnetic resonance guided focused ultrasound surgery (MRgFUS) is an emerging technology that can non-invasively heat and ablate targeted tissue utilizing ultrasound energy. Use of MR imaging for treatment guidance provides several key advantages over more widely used ultrasound guidance for focused ultrasound ablation. MR allows for precise targeting, detailed beam path visualization, real time non-invasive temperature measurement, and treatment feedback to ensure therapeutic goals are achieved. In the realm of oncology, management of painful bone metastases is a common and daunting clinical problem. The Insightec ExAblate System has been shown in phase I/II trials for treatment of bone metastases to have an excellent safety profile and high rates of pain response. An international multi-center phase III trial for patients with painful bone metastases or multiple myeloma who are not candidates for radiation therapy is currently open. Patients are randomized 3:1 to MRgFUS or sham treatment with crossover to study treatment allowed for sham failures. The primary study endpoint is assessment of pain control over 3 months following treatment. In addition safety, quality of life, cost effectiveness analysis, and patient perceived clinical benefit are also being assessed. Details of the MRgFUS system, technical and clinical therapeutic parameters, use of real time non-invasive MR thermometry, and examples of patient treatments with use of MRgFUS to treat bone metastases will be discussed. New directions in use of MRgFUS including an update on development of a new mobile applicator and integration of MRgFUS in multimodality oncologic care will also be presented.

  7. Enhanced thermal effect using magnetic nano-particles during high-intensity focused ultrasound.

    PubMed

    Devarakonda, Surendra Balaji; Myers, Matthew R; Giridhar, Dushyanth; Dibaji, Seyed Ahmad Reza; Banerjee, Rupak Kumar

    2017-01-01

    Collateral damage and long sonication times occurring during high-intensity focused ultrasound (HIFU) ablation procedures limit clinical advancement. In this reserarch, we investigated whether the use of magnetic nano-particles (mNPs) can reduce the power required to ablate tissue or, for the same power, reduce the duration of the procedure. Tissue-mimicking phantoms containing embedded thermocouples and physiologically acceptable concentrations (0%, 0.0047%, and 0.047%) of mNPs were sonicated at acoustic powers of 5.2 W, 9.2 W, and 14.5 W, for 30 seconds. Lesion volumes were determined for the phantoms with and without mNPs. It was found that with the 0.047% mNP concentration, the power required to obtain a lesion volume of 13 mm3 can be halved, and the time required to achieve a 21 mm3 lesion decreased by a factor of 5. We conclude that mNPs have the potential to reduce damage to healthy tissue, and reduce the procedure time, during tumor ablation using HIFU.

  8. Flow-controlled magnetic particle manipulation

    DOEpatents

    Grate, Jay W [West Richland, WA; Bruckner-Lea, Cynthia J [Richland, WA; Holman, David A [Las Vegas, NV

    2011-02-22

    Inventive methods and apparatus are useful for collecting magnetic materials in one or more magnetic fields and resuspending the particles into a dispersion medium, and optionally repeating collection/resuspension one or more times in the same or a different medium, by controlling the direction and rate of fluid flow through a fluid flow path. The methods provide for contacting derivatized particles with test samples and reagents, removal of excess reagent, washing of magnetic material, and resuspension for analysis, among other uses. The methods are applicable to a wide variety of chemical and biological materials that are susceptible to magnetic labeling, including, for example, cells, viruses, oligonucleotides, proteins, hormones, receptor-ligand complexes, environmental contaminants and the like.

  9. Use of the Generating Options for Active Risk Control (GO-ARC) Technique can lead to more robust risk control options.

    PubMed

    Card, Alan J; Simsekler, Mecit Can Emre; Clark, Michael; Ward, James R; Clarkson, P John

    2014-01-01

    Risk assessment is widely used to improve patient safety, but healthcare workers are not trained to design robust solutions to the risks they uncover. This leads to an overreliance on the weakest category of risk control recommendations: administrative controls. Increasing the proportion of non-administrative risk control options (NARCOs) generated would enable (though not ensure) the adoption of more robust solutions. Experimentally assess a method for generating stronger risk controls: The Generating Options for Active Risk Control (GO-ARC) Technique. Participants generated risk control options in response to two patient safety scenarios. Scenario 1 (baseline): All participants used current practice (unstructured brainstorming). Scenario 2: Control group used current practice; intervention group used the GO-ARC Technique. To control for individual differences between participants, analysis focused on the change in the proportion of NARCOs for each group. Proportion of NARCOs decreased from 0.18 at baseline to 0.12. Intervention group: Proportion increased from 0.10 at baseline to 0.29 using the GO-ARC Technique. Results were statistically significant. There was no decrease in the number of administrative controls generated by the intervention group. The Generating Options for Active Risk Control (GO-ARC) Technique appears to lead to more robust risk control options.

  10. Nontraditional Options for Continuing Education in the Health Professions: A Bibliography, 1970-1980.

    ERIC Educational Resources Information Center

    Braymer, Meta R.; Seaton, Jennie D.

    This selected bibliography contains references to over 200 articles published in the last decade that clearly indicate the interest in nontraditional options for continuing education in the health professions. The articles found in approximately 100 professional journals both provide general information about options for study and focus on…

  11. A Novel Variable-Focus Lens for HFGW

    NASA Astrophysics Data System (ADS)

    Woods, R. Clive

    2006-01-01

    Li and Torr published calculations claiming to show that gravitational waves (GWs) propagate inside superconductors with a phase velocity reduction (compared to free space) by a factor n ~ 300× and a wavenumber increase by a factor n. This gives major opportunities for designing future GW components able to focus, refract, reflect, and otherwise manipulate gravitational waves for efficient coupling to detectors, transmitters, generators, resonant chambers, and other sensors. To exploit this result, a novel type of HFGW lens design is proposed here using a magnetic field to adjust the focal length in an infinitely-variable manner. Type-II superconductors do not always completely expel large magnetic fields; above their lower critical field they allow vortices of magnetic flux to channel the magnetic field through the material. Within these vortices, the superconductor is magnetically quenched and so behaves as a non-superconductor. Varying the applied magnetic field varies the proportion of material that is quenched. This subsequently affects GW propagation behavior through a type II superconductor. Therefore, using a suitable non-uniform magnetic field, the GW optical path length may be arranged to vary in a technologically useful manner. A GW lens may be designed with focal length dependent upon the applied magnetic field. Such a lens would be invaluable in the design of advanced GW optics since focusing will be achieved electrically with no moving parts; for this reason it would be unparalleled in conventional optics. Since, therefore, variations in n (due to calculation error limits) can be compensated electrically, successful demonstration of this device would confirm the Li and Torr prediction much more easily than directly using a fixed lens structure. The device would also enable fast auto-focusing, zooming, and imaging tomography using electronic servos following development of the necessary HFGW detectors.

  12. Magnetic materials and devices for the 21st century: stronger, lighter, and more energy efficient.

    PubMed

    Gutfleisch, Oliver; Willard, Matthew A; Brück, Ekkes; Chen, Christina H; Sankar, S G; Liu, J Ping

    2011-02-15

    A new energy paradigm, consisting of greater reliance on renewable energy sources and increased concern for energy efficiency in the total energy lifecycle, has accelerated research into energy-related technologies. Due to their ubiquity, magnetic materials play an important role in improving the efficiency and performance of devices in electric power generation, conditioning, conversion, transportation, and other energy-use sectors of the economy. This review focuses on the state-of-the-art hard and soft magnets and magnetocaloric materials, with an emphasis on their optimization for energy applications. Specifically, the impact of hard magnets on electric motor and transportation technologies, of soft magnetic materials on electricity generation and conversion technologies, and of magnetocaloric materials for refrigeration technologies, are discussed. The synthesis, characterization, and property evaluation of the materials, with an emphasis on structure-property relationships, are discussed in the context of their respective markets, as well as their potential impact on energy efficiency. Finally, considering future bottlenecks in raw materials, options for the recycling of rare-earth intermetallics for hard magnets will be discussed. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. Magnetic resonance-guided shielding of prefocal acoustic obstacles in focused ultrasound therapy: application to intercostal ablation in liver.

    PubMed

    Salomir, Rares; Petrusca, Lorena; Auboiroux, Vincent; Muller, Arnaud; Vargas, Maria-Isabel; Morel, Denis R; Goget, Thomas; Breguet, Romain; Terraz, Sylvain; Hopple, Jerry; Montet, Xavier; Becker, Christoph D; Viallon, Magalie

    2013-06-01

    The treatment of liver cancer is a major public health issue because the liver is a frequent site for both primary and secondary tumors. Rib heating represents a major obstacle for the application of extracorporeal focused ultrasound to liver ablation. Magnetic resonance (MR)-guided external shielding of acoustic obstacles (eg, the ribs) was investigated here to avoid unwanted prefocal energy deposition in the pathway of the focused ultrasound beam. Ex vivo and in vivo (7 female sheep) experiments were performed in this study. Magnetic resonance-guided high-intensity focused ultrasound (MRgHIFU) was performed using a randomized 256-element phased-array transducer (f∼1 MHz) and a 3-T whole-body clinical MR scanner. A physical mask was inserted in the prefocal beam pathway, external to the body, to block the energy normally targeted on the ribs. The effectiveness of the reflecting material was investigated by characterizing the efficacy of high-intensity focused ultrasound beam reflection and scattering on its surface using Schlieren interferometry. Before high-intensity focused ultrasound sonication, the alignment of the protectors with the conical projections of the ribs was required and achieved in multiple steps using the embedded graphical tools of the MR scanner. Multiplanar near real-time MR thermometry (proton resonance frequency shift method) enabled the simultaneous visualization of the local temperature increase at the focal point and around the exposed ribs. The beam defocusing due to the shielding was evaluated from the MR acoustic radiation force impulse imaging data. Both MR thermometry (performed with hard absorber positioned behind a full-aperture blocking shield) and Schlieren interferometry indicated a very good energy barrier of the shielding material. The specific temperature contrast between rib surface (spatial average) and focus, calculated at the end point of the MRgHIFU sonication, with protectors vs no protectors, indicated an important

  14. A Review of Research Methods Used to Examine Employee Assistance Program Delivery Options.

    ERIC Educational Resources Information Center

    Csiernik, Rick

    1995-01-01

    This review of literature on Employee Assistance Programs (EAPs) focuses on EAP delivery options. More than half of the 48 studies reviewed used a case study approach. EAPs provided by on-staff professionals were the most frequently discussed delivery option, although this is not the most dominant form of EAP provision. (SLD)

  15. Magnetic manipulation of particles and cells in ferrofluid flow through straight microchannels using two magnets

    NASA Astrophysics Data System (ADS)

    Zeng, Jian

    Microfluidic devices have been increasingly used in the past two decades for particle and cell manipulations in many chemical and biomedical applications. A variety of force fields have been demonstrated to control particle and cell transport in these devices including electric, magnetic, acoustic, and optical forces etc. Among these particle handling techniques, the magnetic approach provides clear advantages over others such as low cost, noninvasive, and free of fluid heating issues. However, the current knowledge of magnetic control of particle transport is still very limited, especially lacking is the handling of diamagnetic particle. This thesis is focused on the magnetic manipulation of diamagnetic particles and cells in ferrofluid flow through the use of a pair of permanent magnets. By varying the configuration of the two magnets, diverse operations of particles and cells is implemented in a straight microchannel that can potentially be integrated into lab-on-a-chip devices for various applications. First, an approach for embedding two, symmetrically positioned, repulsive permanent magnets about a straight rectangular microchannel in a PDMS-based microfluidic device is developed for particle focusing. Focusing particles and cells into a tight stream is often required in order for continuous detection, counting, and sorting. The closest distance between the magnets is limited only by the size of the magnets involved in the fabrication process. The device is used to implement and investigate the three-dimensional magnetic focusing of polystyrene particles in ferrofluid microflow with both top-view and side-view visualizations. The effects of flow speed and particle size on the particle focusing effectiveness are studied. This device is also applied to magnetically focus yeast cells in ferrofluid, which proves to be biocompatible as verified by cell viability test. In addition, an analytical model is developed and found to be able to predict the experimentally

  16. Electron beam focusing system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dikansky, N.; Nagaitsev, S.; Parkhomchuk, V.

    1997-09-01

    The high energy electron cooling requires a very cold electron beam. Thus, the electron beam focusing system is very important for the performance of electron cooling. A system with and without longitudinal magnetic field is presented for discussion. Interaction of electron beam with the vacuum chamber as well as with the background ions and stored antiprotons can cause the coherent electron beam instabilities. Focusing system requirements needed to suppress these instabilities are presented.

  17. FOREWORD: Focus on Magneto-Science

    NASA Astrophysics Data System (ADS)

    Tanimoto, Yoshifumi; Beaugnon, Eric; Kimura, Tsunehisa; Ozeki, Sumio

    2008-06-01

    , diamagnetic materials such as water and wood can be levitated by applying vertical magnetic fields: magnetic levitation. These phenomena are interpreted in terms of magnetic force. Although the effect of a magnetic force has been well investigated both theoretically and experimentally, before these reports it was difficult to imagine that water could be separated or levitated using magnetic fields, simply because the magnetic force generated by a tabletop electromagnet is not strong enough to demonstrate these phenomena clearly. The magnetic phenomena occurring under a 10 T field markedly differ from those under a 1 T field: strong magnetic fields of approximately 10 T present researchers with a new interdisciplinary field of science, encompassing physics, chemistry and biology, which will also be useful for technological development. Taking these benefits into account, we adopted the term 'magneto-science' (basic and applied), to refer to the investigation of magnetic field effects (MFEs) on physical, chemical and biological phenomena in order to differentiate this new interdisciplinary field from traditional ones. In consideration of the important role of magneto-science in the 21st century, this focus issue contains 16 articles selected from the International Conference on Magneto-Science (ICMS2007), which was held in Hiroshima, Japan in November 2007. The selected papers describe various studies of MFEs (≤ 16 T) in hard, soft and biological materials. Topics such as the magnetic processing of alloys or hard materials, spin chemistry and spin dynamics, magneto-electrochemistry, the magnetic processing of soft materials, the applications of magnetic fields to analysis, and magneto-biology are addressed to delineate the frontiers of magneto-science. We hope that this focus issue will help readers to understand several aspects of the frontiers of magneto-science.

  18. Permanent magnet focused X-band photoinjector

    DOEpatents

    Yu, David U. L.; Rosenzweig, James

    2002-09-10

    A compact high energy photoelectron injector integrates the photocathode directly into a multicell linear accelerator with no drift space between the injection and the linac. High electron beam brightness is achieved by accelerating a tightly focused electron beam in an integrated, multi-cell, X-band rf linear accelerator (linac). The photoelectron linac employs a Plane-Wave-Transformer (PWT) design which provides strong cell-to-cell coupling, easing manufacturing tolerances and costs.

  19. Designing flexible engineering systems utilizing embedded architecture options

    NASA Astrophysics Data System (ADS)

    Pierce, Jeff G.

    This dissertation develops and applies an integrated framework for embedding flexibility in an engineered system architecture. Systems are constantly faced with unpredictability in the operational environment, threats from competing systems, obsolescence of technology, and general uncertainty in future system demands. Current systems engineering and risk management practices have focused almost exclusively on mitigating or preventing the negative consequences of uncertainty. This research recognizes that high uncertainty also presents an opportunity to design systems that can flexibly respond to changing requirements and capture additional value throughout the design life. There does not exist however a formalized approach to designing appropriately flexible systems. This research develops a three stage integrated flexibility framework based on the concept of architecture options embedded in the system design. Stage One defines an eight step systems engineering process to identify candidate architecture options. This process encapsulates the operational uncertainty though scenario development, traces new functional requirements to the affected design variables, and clusters the variables most sensitive to change. The resulting clusters can generate insight into the most promising regions in the architecture to embed flexibility in the form of architecture options. Stage Two develops a quantitative option valuation technique, grounded in real options theory, which is able to value embedded architecture options that exhibit variable expiration behavior. Stage Three proposes a portfolio optimization algorithm, for both discrete and continuous options, to select the optimal subset of architecture options, subject to budget and risk constraints. Finally, the feasibility, extensibility and limitations of the framework are assessed by its application to a reconnaissance satellite system development problem. Detailed technical data, performance models, and cost estimates

  20. Modeling of Solid Waste Processing Options in BIO-Plex

    NASA Technical Reports Server (NTRS)

    Rodriguez, Luis F.; Finn, Cory; Kang, Sukwon; Hogan, John; Luna, Bernadette (Technical Monitor)

    2000-01-01

    BIO-Plex is a ground-based test bed currently under development by NASA for testing technologies and practices that may be utilized in future long-term life support missions. All aspects of such an Advanced Life Support (ALS) System must be considered to confidently construct a reliable system, which will not only allow the crew to survive in harsh environments, but allow the crew time to perform meaningful research. Effective handling of solid wastes is a critical aspect of the system, especially when recovery of resources contained in the waste is required. This is particularly important for ALS Systems configurations that include a Biomass Production Chamber. In these cases, significant amounts of inedible biomass waste may be produced, which can ultimately serve as a repository of necessary resources for sustaining life, notably carbon, water, and plant nutrients. Numerous biological and physicochemical solid waste processing options have been considered. Biological options include composting, aerobic digestion, and anaerobic digestion. Physicochemical options include pyrolysis, SCWO (supercritical water oxidation), various incineration configurations, microwave incineration, magnetically assisted gasification, and low temperature plasma reaction. Modeling of these options is a necessary step to assist in the design process. A previously developed top-level model of BIO-Plex implemented in MATLAB Simulink (r) for the use of systems analysis and design has been adopted for this analysis. Presently, this model only considered incineration for solid waste processing. Present work, reported here, includes the expansion of this model to include a wider array of solid waste processing options selected from the above options, bearing in mind potential, near term solid waste treatment systems. Furthermore, a trade study has also been performed among these solid waste processing technologies in an effort to determine the ideal technology for long-term life support

  1. Patient knowledge on stroke risk factors, symptoms and treatment options.

    PubMed

    Faiz, Kashif Waqar; Sundseth, Antje; Thommessen, Bente; Rønning, Ole Morten

    2018-01-01

    Public campaigns focus primarily on stroke symptom and risk factor knowledge, but patients who correctly recognize stroke symptoms do not necessarily know the reason for urgent hospitalization. The aim of this study was to explore knowledge on stroke risk factors, symptoms and treatment options among acute stroke and transient ischemic attack patients. This prospective study included patients admitted to the stroke unit at the Department of Neurology, Akershus University Hospital, Norway. Patients with previous cerebrovascular disease, patients receiving thrombolytic treatment and patients who were not able to answer the questions in the questionnaire were excluded. Patients were asked two closed-ended questions: "Do you believe that stroke is a serious disorder?" and "Do you believe that time is of importance for stroke treatment?". In addition, patients were asked three open-ended questions where they were asked to list as many stroke risk factors, stroke symptoms and stroke treatment options as they could. A total of 173 patients were included, of whom 158 (91.3%) confirmed that they regarded stroke as a serious disorder and 148 patients (85.5%) considered time being of importance. In all, 102 patients (59.0%) could not name any treatment option. Forty-one patients (23.7%) named one or more adequate treatment options, and they were younger ( p <0.001) and had higher educational level ( p <0.001), but had a nonsignificant shorter prehospital delay time ( p =0.292). The level of stroke treatment knowledge in stroke patients seems to be poor. Public campaigns should probably also focus on information on treatment options, which may contribute to reduce prehospital delay and onset-to-treatment-time.

  2. Cyanobacterial Treatment Options: Permanganate and ...

    EPA Pesticide Factsheets

    This presentation will begin with a brief overview of drinking water treatment options for cyanobacteria and their toxins. The treatment discussion will focus on the impacts of permanganate addition to suspensions of toxin-producing Microcystis aeruginosa, followed by powdered activated carbon (PAC) addition. Results will be presented that show changes in toxin concentrations, chlorophyll-a concentrations and cell membrane integrity. The EPA Small Systems Webinar Presentations allow the dissemination of the latest Agency guidance and research to a large geographically dispersed audience while minimizing taxpayer expense

  3. Repurposing Used Electric Car Batteries: A Review of Options

    NASA Astrophysics Data System (ADS)

    DeRousseau, Mikaela; Gully, Benjamin; Taylor, Christopher; Apelian, Diran; Wang, Yan

    2017-09-01

    In the United States, millions of electric and hybrid vehicles have cumulatively been sold. Although the batteries in these vehicles are expected to last at least 8 years, end-of-life options must still be considered. There are several possible options for battery packs from electric vehicles when they reach end-of-life, including remanufacturing, repurposing for a different application, and recycling. Remanufacturing is the most desirable end-of-life scenario but is the most stringent in terms of battery quality. Recycling is less desirable because there are larger material and energy losses that occur in the process. Repurposing batteries for a different use lies between these two scenarios in terms of desirability. This review paper focuses on non-automotive reuse and explores several options for using electric car battery packs in grid energy storage applications.

  4. Understanding Magnetic Resonance Imaging of Knee Cartilage Repair: A Focus on Clinical Relevance.

    PubMed

    Hayashi, Daichi; Li, Xinning; Murakami, Akira M; Roemer, Frank W; Trattnig, Siegfried; Guermazi, Ali

    2017-06-01

    The aims of this review article are (a) to describe the principles of morphologic and compositional magnetic resonance imaging (MRI) techniques relevant for the imaging of knee cartilage repair surgery and their application to longitudinal studies and (b) to illustrate the clinical relevance of pre- and postsurgical MRI with correlation to intraoperative images. First, MRI sequences that can be applied for imaging of cartilage repair tissue in the knee are described, focusing on comparison of 2D and 3D fast spin echo and gradient recalled echo sequences. Imaging features of cartilage repair tissue are then discussed, including conventional (morphologic) MRI and compositional MRI techniques. More specifically, imaging techniques for specific cartilage repair surgery techniques as described above, as well as MRI-based semiquantitative scoring systems for the knee cartilage repair tissue-MR Observation of Cartilage Repair Tissue and Cartilage Repair OA Knee Score-are explained. Then, currently available surgical techniques are reviewed, including marrow stimulation, osteochondral autograft, osteochondral allograft, particulate cartilage allograft, autologous chondrocyte implantation, and others. Finally, ongoing research efforts and future direction of cartilage repair tissue imaging are discussed.

  5. Electron-Focus Adjustment for Photo-Optical Imagers

    NASA Technical Reports Server (NTRS)

    Fowler, Walter B.; Flemming, Keith; Ziegler, Michael M.

    1987-01-01

    Internal electron focus made independent of optical focus. Procedure enables fine tuning of internal electron-focusing system of photo-optical imager, without complication by imperfections of associated external optics. Applicable to imager in which electrons emitted from photocathode in optical focal plane, then electrostatically and/or magnetically focused to replica of image in second focal plane containing photodiodes, phototransistorss, charge-coupled devices, multiple-anode outputs, or other detectors.

  6. The European style arithmetic Asian option pricing with stochastic interest rate based on Black Scholes model

    NASA Astrophysics Data System (ADS)

    Winarti, Yuyun Guna; Noviyanti, Lienda; Setyanto, Gatot R.

    2017-03-01

    The stock investment is a high risk investment. Therefore, there are derivative securities to reduce these risks. One of them is Asian option. The most fundamental of option is option pricing. Many factors that determine the option price are underlying asset price, strike price, maturity date, volatility, risk free interest rate and dividends. Various option pricing usually assume that risk free interest rate is constant. While in reality, this factor is stochastic process. The arithmetic Asian option is free from distribution, then, its pricing is done using the modified Black-Scholes model. In this research, the modification use the Curran approximation. This research focuses on the arithmetic Asian option pricing without dividends. The data used is the stock daily closing data of Telkom from January 1 2016 to June 30 2016. Finnaly, those option price can be used as an option trading strategy.

  7. Cognitive and Affective Aspects of Creative Option Generation in Everyday Life Situations.

    PubMed

    Schweizer, T Sophie; Schmalenberger, Katja M; Eisenlohr-Moul, Tory A; Mojzisch, Andreas; Kaiser, Stefan; Funke, Joachim

    2016-01-01

    Which factors influence a human being's ability to develop new perspectives and be creative? This ability is pivotal for any context in which new cognitions are required, such as innovative endeavors in science and art, or psychotherapeutic settings. In this article, we seek to bring together two research programs investigating the generation of creative options: On the one hand, research on option generation in the decision-making literature and, on the other hand, cognitive and clinical creativity research. Previous decision-making research has largely neglected the topic of generating creative options. Experiments typically provided participants with a clear set of options to choose from, but everyday life situations are less structured and allow countless ways to react. Before choosing an option, agents have to self-generate a set of options to choose from. Such option generation processes have only recently moved to the center of attention. The present study examines the creative quality of self-generated options in daily life situations. A student sample (N = 48) generated options for action in 70 briefly described everyday life scenarios. We rated the quality of the options on three dimensions of creativity- originality, feasibility, and divergence -and linked these qualities to option generation fluency (speed and number of generated options), situational features like the familiarity and the affective valence of the situation in which the options were generated, and trait measures of cognitive performance. We found that when situations were familiar to the participant, greater negative affective valence of the situation was associated with more originality and divergence of generated options. We also found that a higher option generation fluency was associated with a greater maximal originality of options. We complete our article with a joint research agenda for researchers in the decision-making field focusing on option generation and, on the other hand

  8. Focusing, collimation and flux throughput at the IMCA-CAT bending-magnet beamline at the Advanced Photon Source

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Koshelev, Irina; Huang, Rong; Graber, Timothy

    2009-09-02

    The IMCA-CAT bending-magnet beamline was upgraded with a collimating mirror in order to achieve the energy resolution required to conduct high-quality multi- and single-wavelength anomalous diffraction (MAD/SAD) experiments without sacrificing beamline flux throughput. Following the upgrade, the bending-magnet beamline achieves a flux of 8 x 10{sup 11} photons s{sup -1} at 1 {angstrom} wavelength, at a beamline aperture of 1.5 mrad (horizontal) x 86 {mu}rad (vertical), with energy resolution (limited mostly by the intrinsic resolution of the monochromator optics) {delta}E/E = 1.5 x 10{sup -4} (at 10 kV). The beamline operates in a dynamic range of 7.5-17.5 keV and deliversmore » to the sample focused beam of size (FWHM) 240 {micro}m (horizontally) x 160 {micro}m (vertically). The performance of the 17-BM beamline optics and its deviation from ideally shaped optics is evaluated in the context of the requirements imposed by the needs of protein crystallography experiments. An assessment of flux losses is given in relation to the (geometric) properties of major beamline components.« less

  9. Solar PV leasing in Singapore: enhancing return on investments with options

    NASA Astrophysics Data System (ADS)

    Song, Shuang; Poh, K. L.

    2017-05-01

    Renewable energy is getting more important nowadays as an alternative to traditional energies. Solar energy, according to Energy Market Authority, is the most viable in the context of Singapore compared to other renewable energy sources due to land constraints. In light of the increasing adoption of solar power in Singapore, this paper focuses on solar PV leasing using a case study. This paper assesses the prospect for solar PV leasing companies in Singapore through the lens of embedded real options. The recent news that solar power is becoming the cheapest form of new electricity presents the leasing company an option to expand the scale of solar PV system. Taking into account this option, the Net Present Value (NPV) of the investment increased significantly compared to the case without real options. Technological developments result in a continuously changing environment with uncertainties. Thus, decision makers need to be aware of the inherent risk associated and identify options to maximize NPV. This upside potential is realized by exercising the managerial flexibility and exploiting the uncertainty. The paper enables solar energy planners to consider possible managerial flexibilities under uncertainties, showing how option thinking can be incorporated in the valuation of solar energy.

  10. Proximity Operations for the Robotic Boulder Capture Option for the Asteroid Redirect Mission

    NASA Technical Reports Server (NTRS)

    Reeves, David M.; Naasz, Bo J.; Wright, Cinnamon A.; Pini, Alex J.

    2014-01-01

    In September of 2013, the Asteroid Robotic Redirect Mission (ARRM) Option B team was formed to expand on NASA's previous work on the robotic boulder capture option. While the original Option A concept focuses on capturing an entire smaller Near-Earth Asteroid (NEA) using an inflatable bag capture mechanism, this design seeks to land on a larger NEA and retrieve a boulder off of its surface. The Option B team has developed a detailed and feasible mission concept that preserves many aspects of Option A's vehicle design while employing a fundamentally different technique for returning a significant quantity of asteroidal material to the Earth-Moon system. As part of this effort, a point of departure proximity operations concept was developed complete with a detailed timeline, as well as DeltaV and propellant allocations. Special attention was paid to the development of the approach strategy, terminal descent to the surface, controlled ascent with the captured boulder, and control during the Enhanced Gravity Tractor planetary defense demonstration. The concept of retrieving a boulder from the surface of an asteroid and demonstrating the Enhanced Gravity Tractor planetary defense technique is found to be feasible and within the proposed capabilities of the Asteroid Redirect Vehicle (ARV). While this point of departure concept initially focuses on a mission to Itokawa, the proximity operations design is also shown to be extensible to wide range of asteroids.

  11. Advanced methods for controlling untethered magnetic devices using rotating magnetic fields

    NASA Astrophysics Data System (ADS)

    Mahoney, Arthur W., Jr.

    This dissertation presents results documenting advancements on the control of untethered magnetic devices, such as magnetic "microrobots" and magnetically actuated capsule endoscopes, motivated by problems in minimally invasive medicine. This dissertation focuses on applying rotating magnetic fields for magnetic manipulation. The contributions include advancements in the way that helical microswimmers (devices that mimic the propulsion of bacterial flagella) are controlled in the presence of gravitational forces, advancements in ways that groups of untethered magnetic devices can be differentiated and semi-independently controlled, advancements in the way that untethered magnetic device can be controlled with a single rotating permanent magnet, and an improved understanding in the nature of the magnetic force applied to an untethered device by a rotating magnet.

  12. Magnetic resonance imaging-guided focused ultrasound treatment of symptomatic uterine fibroids: impact of technology advancement on ablation volumes in 115 patients.

    PubMed

    Trumm, Christoph G; Stahl, Robert; Clevert, Dirk-André; Herzog, Peter; Mindjuk, Irene; Kornprobst, Sabine; Schwarz, Christina; Hoffmann, Ralf-Thorsten; Reiser, Maximilian F; Matzko, Matthias

    2013-06-01

    The aim of this study was to assess the impact of the advanced technology of the new ExAblate 2100 system (Insightec Ltd, Haifa, Israel) for magnetic resonance imaging (MRI)-guided focused ultrasound surgery on treatment outcomes in patients with symptomatic uterine fibroids, as measured by the nonperfused volume ratio. This is a retrospective analysis of 115 women (mean age, 42 years; range, 27-54 years) with symptomatic fibroids who consecutively underwent MRI-guided focused ultrasound treatment in a single center with the new generation ExAblate 2100 system from November 2010 to June 2011. Mean ± SD total volume and number of treated fibroids (per patient) were 89 ± 94 cm and 2.2 ± 1.7, respectively. Patient baseline characteristics were analyzed regarding their impact on the resulting nonperfused volume ratio. Magnetic resonance imaging-guided focused ultrasound treatment was technically successful in 115 of 123 patients (93.5%). In 8 patients, treatment was not possible because of bowel loops in the beam pathway that could not be mitigated (n = 6), patient movement (n = 1), and system malfunction (n = 1). Mean nonperfused volume ratio was 88% ± 15% (range, 38%-100%). Mean applied energy level was 5400 ± 1200 J, and mean number of sonications was 74 ± 27. No major complications occurred. Two cases of first-degree skin burn resolved within 1 week after the intervention. Of the baseline characteristics analyzed, only the planned treatment volume had a statistically significant impact on nonperfused volume ratio. With technological advancement, the outcome of MRI-guided focused ultrasound treatment in terms of the nonperfused volume ratio can be enhanced with a high safety profile, markedly exceeding results reported in previous clinical trials.

  13. Effects of humidity on the magnetic and woody characteristics of powder-type magnetic wood

    NASA Astrophysics Data System (ADS)

    Oka, H.; Tokuta, H.; Namizaki, Y.; Sekino, N.

    2004-05-01

    Among three types of proposed magnetic wood, powder-type magnetic wood can be made of recycled magnetic materials from IT devices, consumer electronics and waste wood. Because of its wood powder content, powder-type magnetic wood shows special characteristics different from those of typical magnetic materials. We focused on the relationship between humidity and magnetic characteristics of powder-type magnetic wood. The magnetic powder ratio, wood powder density and magnetic binder density were all examined as parameters for AC permeability.

  14. Options in Education, Transcript: Fantasy Magazine, Program No. 33.

    ERIC Educational Resources Information Center

    George Washington Univ., Washington, DC. Inst. for Educational Leadership.

    "Options in Education" is a radio news program which focuses on issues and developments in education. This transcript contains discussions with Bruno Bettelheim on the importance of fairy tales for children, with Frank Williams on tensions in children when they try to create, and with Donald Bigelow on "Loudmouse" by Richard…

  15. Magnetoresistive flux focusing eddy current flaw detection

    NASA Technical Reports Server (NTRS)

    Wincheski, Russell A. (Inventor); Simpson, John W. (Inventor); Namkung, Min (Inventor)

    2005-01-01

    A giant magnetoresistive flux focusing eddy current device effectively detects deep flaws in thick multilayer conductive materials. The probe uses an excitation coil to induce eddy currents in conducting material perpendicularly oriented to the coil's longitudinal axis. A giant magnetoresistive (GMR) sensor, surrounded by the excitation coil, is used to detect generated fields. Between the excitation coil and GMR sensor is a highly permeable flux focusing lens which magnetically separates the GMR sensor and excitation coil and produces high flux density at the outer edge of the GMR sensor. The use of feedback inside the flux focusing lens enables complete cancellation of the leakage fields at the GMR sensor location and biasing of the GMR sensor to a location of high magnetic field sensitivity. In an alternate embodiment, a permanent magnet is positioned adjacent to the GMR sensor to accomplish the biasing. Experimental results have demonstrated identification of flaws up to 1 cm deep in aluminum alloy structures. To detect deep flaws about circular fasteners or inhomogeneities in thick multilayer conductive materials, the device is mounted in a hand-held rotating probe assembly that is connected to a computer for system control, data acquisition, processing and storage.

  16. Magnetoresistive Flux Focusing Eddy Current Flaw Detection

    NASA Technical Reports Server (NTRS)

    Wincheski, Russell A. (Inventor); Namkung, Min (Inventor); Simpson, John W. (Inventor)

    2005-01-01

    A giant magnetoresistive flux focusing eddy current device effectively detects deep flaws in thick multilayer conductive materials. The probe uses an excitation coil to induce eddy currents in conducting material perpendicularly oriented to the coil s longitudinal axis. A giant magnetoresistive (GMR) sensor, surrounded by the excitation coil, is used to detect generated fields. Between the excitation coil and GMR sensor is a highly permeable flux focusing lens which magnetically separates the GMR sensor and excitation coil and produces high flux density at the outer edge of the GMR sensor. The use of feedback inside the flux focusing lens enables complete cancellation of the leakage fields at the GMR sensor location and biasing of the GMR sensor to a location of high magnetic field sensitivity. In an alternate embodiment, a permanent magnet is positioned adjacent to the GMR sensor to accomplish the biasing. Experimental results have demonstrated identification of flaws up to 1 cm deep in aluminum alloy structures. To detect deep flaws about circular fasteners or inhomogeneities in thick multi-layer conductive materials, the device is mounted in a hand-held rotating probe assembly that is connected to a computer for system control, data acquisition, processing and storage.

  17. Adaptive model-predictive controller for magnetic resonance guided focused ultrasound therapy.

    PubMed

    de Bever, Joshua; Todd, Nick; Payne, Allison; Christensen, Douglas A; Roemer, Robert B

    2014-11-01

    Minimising treatment time and protecting healthy tissues are conflicting goals that play major roles in making magnetic resonance image-guided focused ultrasound (MRgFUS) therapies clinically practical. We have developed and tested in vivo an adaptive model-predictive controller (AMPC) that reduces treatment time, ensures safety and efficacy, and provides flexibility in treatment set-up. The controller realises time savings by modelling the heated treatment cell's future temperatures and thermal dose accumulation in order to anticipate the optimal time to switch to the next cell. Selected tissues are safeguarded by a configurable temperature constraint. Simulations quantified the time savings realised by each controller feature as well as the trade-offs between competing safety and treatment time parameters. In vivo experiments in rabbit thighs established the controller's effectiveness and reliability. In all in vivo experiments the target thermal dose of at least 240 CEM43 was delivered everywhere in the treatment volume. The controller's temperature safety limit reliably activated and constrained all protected tissues to <9 CEM43. Simulations demonstrated the path independence of the controller, and that a path which successively proceeds to the hottest untreated neighbouring cell leads to significant time savings, e.g. when compared to a concentric spiral path. Use of the AMPC produced a compounding time-saving effect; reducing the treatment cells' heating times concurrently reduced heating of normal tissues, which eliminated cooling periods. Adaptive model-predictive control can automatically deliver safe, effective MRgFUS treatments while significantly reducing treatment times.

  18. Magnetic Trapping of Bacteria at Low Magnetic Fields

    NASA Astrophysics Data System (ADS)

    Wang, Z. M.; Wu, R. G.; Wang, Z. P.; Ramanujan, R. V.

    2016-06-01

    A suspension of non-magnetic entities in a ferrofluid is referred to as an inverse ferrofluid. Current research to trap non-magnetic entities in an inverse ferrofluid focuses on using large permanent magnets to generate high magnetic field gradients, which seriously limits Lab-on-a-Chip applications. On the other hand, in this work, trapping of non-magnetic entities, e.g., bacteria in a uniform external magnetic field was studied with a novel chip design. An inverse ferrofluid flows in a channel and a non-magnetic island is placed in the middle of this channel. The magnetic field was distorted by this island due to the magnetic susceptibility difference between this island and the surrounding ferrofluid, resulting in magnetic forces applied on the non-magnetic entities. Both the ferromagnetic particles and the non-magnetic entities, e.g., bacteria were attracted towards the island, and subsequently accumulate in different regions. The alignment of the ferrimagnetic particles and optical transparency of the ferrofluid was greatly enhanced by the bacteria at low applied magnetic fields. This work is applicable to lab-on-a-chip based detection and trapping of non-magnetic entities bacteria and cells.

  19. Rehabilitation Options

    MedlinePlus

    ... Speech Pathology Occupational Therapy Art Therapy Recreational therapy Neuropsychology Home Care Options Advanced Care Planning Palliative Care ... Speech Pathology Occupational Therapy Art Therapy Recreational therapy Neuropsychology Home Care Options Advanced Care Planning Palliative Care ...

  20. Research-Based Options for Education Policymaking: Regulating Charter Schools

    ERIC Educational Resources Information Center

    Mathis, William J.

    2016-01-01

    This is a section of "Research-Based Options for Education Policymaking," a multipart brief that takes up a number of important policy issues and identifies policies supported by research. Each section focuses on a different issue, and its recommendations to policymakers are based on the latest scholarship. A founding premise of charter…

  1. Didactic Considerations on Magnetic Circuits Excited by Permanent Magnets

    ERIC Educational Resources Information Center

    Barmada, S.; Rizzo, R.; Sani, L.

    2009-01-01

    In this paper, the authors focus their attention on the way magnetic circuits and permanent magnets are usually treated in most textbooks and electrical engineering courses. This paper demonstrates how this important topic is too often presented simplistically. This simplistic treatment does not allow the students to develop a complete…

  2. 5 CFR 870.705 - Amount and election of Option B and Option C.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 5 Administrative Personnel 2 2010-01-01 2010-01-01 false Amount and election of Option B and Option C. 870.705 Section 870.705 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT (CONTINUED... Compensationers § 870.705 Amount and election of Option B and Option C. (a) The number of multiples of Option B...

  3. Treatment envelope evaluation in transcranial magnetic resonance-guided focused ultrasound utilizing 3D MR thermometry

    PubMed Central

    2014-01-01

    Background Current clinical targets for transcranial magnetic resonance-guided focused ultrasound (tcMRgFUS) are all located close to the geometric center of the skull convexity, which minimizes challenges related to focusing the ultrasound through the skull bone. Non-central targets will have to be reached to treat a wider variety of neurological disorders and solid tumors. Treatment envelope studies utilizing two-dimensional (2D) magnetic resonance (MR) thermometry have previously been performed to determine the regions in which therapeutic levels of FUS can currently be delivered. Since 2D MR thermometry was used, very limited information about unintended heating in near-field tissue/bone interfaces could be deduced. Methods In this paper, we present a proof-of-concept treatment envelope study with three-dimensional (3D) MR thermometry monitoring of FUS heatings performed in a phantom and a lamb model. While the moderate-sized transducer used was not designed for transcranial geometries, the 3D temperature maps enable monitoring of the entire sonication field of view, including both the focal spot and near-field tissue/bone interfaces, for full characterization of all heating that may occur. 3D MR thermometry is achieved by a combination of k-space subsampling and a previously described temporally constrained reconstruction method. Results We present two different types of treatment envelopes. The first is based only on the focal spot heating—the type that can be derived from 2D MR thermometry. The second type is based on the relative near-field heating and is calculated as the ratio between the focal spot heating and the near-field heating. This utilizes the full 3D MR thermometry data achieved in this study. Conclusions It is shown that 3D MR thermometry can be used to improve the safety assessment in treatment envelope evaluations. Using a non-optimal transducer, it is shown that some regions where therapeutic levels of FUS can be delivered, as suggested by

  4. Hemorrhoidectomy - making sense of the surgical options

    PubMed Central

    Yeo, Danson; Tan, Kok-Yang

    2014-01-01

    While debate continues as to which is the best surgical method for the treatment of hemorrhoids, none of the currently available surgical methods approach the ideal surgical option, which is one that is effective while being safe and painless. In reality, the less painful the procedure, the more likely it is to be associated with recurrence post-op. Where hemorrhoids surgery is concerned, there isn’t a “one size fits all” option. Most of the randomized controlled trials performed to date include hemorrhoids of various grades and with a focus on only comparing surgical methods while failing to stratify the outcomes according to the grade of hemorrhoid. We believe that surgery needs to be tailored not only to the grade of the hemorrhoids, but also to the size, circumferential nature of the disease, and prevailing symptomatology. PMID:25493010

  5. Hemorrhoidectomy - making sense of the surgical options.

    PubMed

    Yeo, Danson; Tan, Kok-Yang

    2014-12-07

    While debate continues as to which is the best surgical method for the treatment of hemorrhoids, none of the currently available surgical methods approach the ideal surgical option, which is one that is effective while being safe and painless. In reality, the less painful the procedure, the more likely it is to be associated with recurrence post-op. Where hemorrhoids surgery is concerned, there isn't a "one size fits all" option. Most of the randomized controlled trials performed to date include hemorrhoids of various grades and with a focus on only comparing surgical methods while failing to stratify the outcomes according to the grade of hemorrhoid. We believe that surgery needs to be tailored not only to the grade of the hemorrhoids, but also to the size, circumferential nature of the disease, and prevailing symptomatology.

  6. Waste battery treatment options: comparing their environmental performance.

    PubMed

    Briffaerts, K; Spirinckx, C; Van der Linden, A; Vrancken, K

    2009-08-01

    Waste consumer batteries are recycled using different routes based on hydrometallurgical and pyrometallurgical processes. Two hydrometallurgical and two pyrometallurgical treatment scenarios are compared starting from an average composition of Belgian waste batteries. The environmental performance is compared using life cycle analysis (LCA). The recycling rate is studied through mass balance calculation. Each treatment scenario results in a specific recycling rate. The environmental impact and benefits also vary between the treatment options. There is no such thing as a typical hydrometallurgical or pyrometallurgical treatment. When applying a hydrometallurgical treatment scenario, the focus lies on zinc and iron recycling. When allowing manganese recycling, the energy demand of the hydrometallurgical process increases considerably. Both pyrometallurgical options recycle zinc, iron and manganese. According to the LCA, none of the treatment scenarios performs generally better or worse than the others. Each option has specific advantages and disadvantages. The Batteries Directive 2006/66/EC sets out a recycling rate of 50% for consumer waste batteries. Based on metal recycling alone, the mass balances show that the target is difficult to obtain.

  7. A discontinuous Galerkin method for numerical pricing of European options under Heston stochastic volatility

    NASA Astrophysics Data System (ADS)

    Hozman, J.; Tichý, T.

    2016-12-01

    The paper is based on the results from our recent research on multidimensional option pricing problems. We focus on European option valuation when the price movement of the underlying asset is driven by a stochastic volatility following a square root process proposed by Heston. The stochastic approach incorporates a new additional spatial variable into this model and makes it very robust, i.e. it provides a framework to price a variety of options that is closer to reality. The main topic is to present the numerical scheme arising from the concept of discontinuous Galerkin methods and applicable to the Heston option pricing model. The numerical results are presented on artificial benchmarks as well as on reference market data.

  8. Large animal models in experimental knee sports surgery: focus on clinical translation.

    PubMed

    Madry, Henning; Ochi, Mitsuo; Cucchiarini, Magali; Pape, Dietrich; Seil, Romain

    2015-12-01

    Large animal models play a crucial role in sports surgery of the knee, as they are critical for the exploration of new experimental strategies and the clinical translation of novel techniques. The purpose of this contribution is to provide critical aspects of relevant animal models in this field, with a focus on paediatric anterior cruciate ligament (ACL) reconstruction, high tibial osteotomy, and articular cartilage repair. Although there is no single large animal model strictly replicating the human knee joint, the sheep stifle joint shares strong similarities. Studies in large animal models of paediatric ACL reconstruction identified specific risk factors associated with the different surgical techniques. The sheep model of high tibial osteotomy is a powerful new tool to advance the understanding of the effect of axial alignment on the lower extremity on specific issues of the knee joint. Large animal models of both focal chondral and osteochondral defects and of osteoarthritis have brought new findings about the mechanisms of cartilage repair and treatment options. The clinical application of a magnetic device for targeted cell delivery serves as a suitable example of how data from such animal models are directly translated into in clinical cartilage repair. As novel insights from studies in these translational models will advance the basic science, close cooperation in this important field of clinical translation will improve current reconstructive surgical options and open novel avenues for regenerative therapies of musculoskeletal disorders.

  9. Light focusing using epsilon-near-zero metamaterials

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhu, Weiren, E-mail: weiren.zhu@monash.edu; Premaratne, Malin; Si, Li-Ming, E-mail: lms@bit.edu.cn

    2013-11-15

    We present a strategy of focusing light using epsilon-near-zero metamaterials with embedded dielectric cylinder. The focusing mechanism is analytically investigated, and its accuracy is substantiated by rigorous full-wave simulations. It is found that the focusing intensity is highly depend on the embedded medium and its size, and the magnetic field amplitude of the focused beam itself can reach as high as 98.2 times the incident field. Owing to its versatility, the proposed light focusing system is sure to find applications in fields such as bio-sensing and in nonlinear optics.

  10. Cognitive and Affective Aspects of Creative Option Generation in Everyday Life Situations

    PubMed Central

    Schweizer, T. Sophie; Schmalenberger, Katja M.; Eisenlohr-Moul, Tory A.; Mojzisch, Andreas; Kaiser, Stefan; Funke, Joachim

    2016-01-01

    Which factors influence a human being’s ability to develop new perspectives and be creative? This ability is pivotal for any context in which new cognitions are required, such as innovative endeavors in science and art, or psychotherapeutic settings. In this article, we seek to bring together two research programs investigating the generation of creative options: On the one hand, research on option generation in the decision-making literature and, on the other hand, cognitive and clinical creativity research. Previous decision-making research has largely neglected the topic of generating creative options. Experiments typically provided participants with a clear set of options to choose from, but everyday life situations are less structured and allow countless ways to react. Before choosing an option, agents have to self-generate a set of options to choose from. Such option generation processes have only recently moved to the center of attention. The present study examines the creative quality of self-generated options in daily life situations. A student sample (N = 48) generated options for action in 70 briefly described everyday life scenarios. We rated the quality of the options on three dimensions of creativity- originality, feasibility, and divergence -and linked these qualities to option generation fluency (speed and number of generated options), situational features like the familiarity and the affective valence of the situation in which the options were generated, and trait measures of cognitive performance. We found that when situations were familiar to the participant, greater negative affective valence of the situation was associated with more originality and divergence of generated options. We also found that a higher option generation fluency was associated with a greater maximal originality of options. We complete our article with a joint research agenda for researchers in the decision-making field focusing on option generation and, on the other hand

  11. Chapter 7: Renewable Energy Options and Considerations for Net Zero Installations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Booth, Samuel

    This chapter focuses on renewable energy options for military installations. It discusses typical renewable technologies, project development, and gives examples. Renewable energy can be combined with conventional energy sources to provide part or all of the energy demand at an installation. The appropriate technology mix for an installation will depend on site-specific factors such as renewable resources, energy costs, local energy policies and incentives, available land, mission compatibility, and other factors. The objective of this chapter is to provide basic background information and resources on renewable energy options for NATO leaders and energy personnel.

  12. Energy for Development: Third World Options. Worldwatch Paper 15.

    ERIC Educational Resources Information Center

    Hayes, Denis

    Focusing on the need for energy to sustain economic development on a long-term basis, the document examines energy options of the post-petroleum era in developing nations. Nuclear power and solar power are the most important among proposed alternative energy sources. Limited applicability of nuclear technology to the Third World is discussed.…

  13. Magnetic Enhancement of Stem Cell-Targeted Delivery into the Brain Following MR-Guided Focused Ultrasound for Opening the Blood-Brain Barrier.

    PubMed

    Shen, Wei-Bin; Anastasiadis, Pavlos; Nguyen, Ben; Yarnell, Deborah; Yarowsky, Paul J; Frenkel, Victor; Fishman, Paul S

    2017-07-01

    Focused ultrasound (FUS)-mediated blood-brain barrier disruption (BBBD) can enable even large therapeutics such as stem cells to enter the brain from the bloodstream. However, the efficiency is relatively low. Our previous study showed that human neural progenitor cells (hNPCs) loaded with superparamagnetic iron oxide nanoparticles (SPIONs) in culture were attracted by an external magnetic field. In vivo, enhanced brain retention was observed near a magnet mounted on the skull in a rat model of traumatic brain injury, where BBBD also occurs. The goal of the current study was to determine whether magnetic attraction of SPION-loaded hNPCs would also enhance their retention in the brain after FUS-mediated BBBD. A small animal magnetic resonance imaging (MRI)-guided FUS system operating at 1.5 MHz was used to treat rats (∼120 g) without tissue damage or hemorrhage. Evidence of successful BBBD was validated with both radiologic enhancement of gadolinium on postsonication TI MRI and whole brain section visualization of Evans blue dye. The procedure was then combined with the application of a powerful magnet to the head directly after intravenous injection of the hNPCs. Validation of cells within the brain was performed by staining with Perls' Prussian blue for iron and by immunohistochemistry with a human-specific antigen. By injecting equal numbers of iron oxide (SPIONs) and noniron oxide nanoparticles-loaded hNPCs, each labeled with a different fluorophore, we found significantly greater numbers of SPIONs-loaded cells retained in the brain at the site of BBBD as compared to noniron loaded cells. This result was most pronounced in regions of the brain closest to the skull (dorsal cortex) in proximity to the magnet surface. A more powerful magnet and a Halbach magnetic array resulted in more effective retention of SPION-labeled cells in even deeper brain regions such as the striatum and ventral cortex. There, up to 90% of hNPCs observed contained SPIONs compared to 60

  14. Longitudinal Gradient Dipole Magnet Prototype for APS at ANL

    DOE PAGES

    Kashikhin, V. S.; Borland, M.; Chlachidze, G.; ...

    2016-01-26

    We planned an upgrade of the Advanced Photon Source at Argonne National Laboratory (ANL). The main goal of the upgrade is to improve the storage ring performance based on more advanced optics. One of the key magnet system elements is bending dipole magnets having a field strength change along the electron beam path. Moreover, a prototype of one such longitudinal gradient dipole magnet has been designed, built, and measured in a collaborative effort of ANL and Fermilab. Our paper discusses various magnetic design options, the selected magnet design, and the fabrication technology. The prototype magnet has been measured by rotationalmore » coils, a stretched wire, and a Hall probe. Measurement results are discussed and compared with simulations.« less

  15. Thickness-modulated tungsten-carbon superconducting nanostructures grown by focused ion beam induced deposition for vortex pinning up to high magnetic fields.

    PubMed

    Serrano, Ismael García; Sesé, Javier; Guillamón, Isabel; Suderow, Hermann; Vieira, Sebastián; Ibarra, Manuel Ricardo; De Teresa, José María

    2016-01-01

    We report efficient vortex pinning in thickness-modulated tungsten-carbon-based (W-C) nanostructures grown by focused ion beam induced deposition (FIBID). By using FIBID, W-C superconducting films have been created with thickness modulation properties exhibiting periodicity from 60 to 140 nm, leading to a strong pinning potential for the vortex lattice. This produces local minima in the resistivity up to high magnetic fields (2.2 T) in a broad temperature range due to commensurability effects between the pinning potential and the vortex lattice. The results show that the combination of single-step FIBID fabrication of superconducting nanostructures with built-in artificial pinning landscapes and the small intrinsic random pinning potential of this material produces strong periodic pinning potentials, maximizing the opportunities for the investigation of fundamental aspects in vortex science under changing external stimuli (e.g., temperature, magnetic field, electrical current).

  16. Halbach array type focusing actuator for small and thin optical data storage device

    NASA Astrophysics Data System (ADS)

    Lee, Sung Q.; Park, Kang-Ho; Paek, Mun Chul

    2004-09-01

    The small form factor optical data storage devices are developing rapidly nowadays. Since it is designed for portable and compatibility with flesh memory, its components such as disk, head, focusing actuator, and spindle motor should be assembled within 5 mm. The thickness of focusing actuator is within 2 mm and the total working range is +/-100um, with the resolution of less than 1μm. Since the thickness is limited tightly, it is hard to place the yoke that closes the magnetic circuit and hard to make strong flux density without yoke. Therefore, Halbach array is adopted to increase the magnetic flux of one side without yoke. The proposed Halbach array type focusing actuator has the advantage of thin actuation structure with sacrificing less flex density than conventional magnetic array. The optical head unit is moved on the swing arm type tracking actuator. Focusing coil is attached to swing arm, and Halbach magnet array is positioned at the bottom of deck along the tracking line, and focusing actuator exerts force by the Fleming's left hand rule. The dynamics, working range, control resolution of focusing actuator are analyzed and performed.

  17. What Happens When Schools Become Magnet Schools? A Longitudinal Study of Diversity and Achievement

    ERIC Educational Resources Information Center

    Kitmitto, Sami; Levin, Jesse; Betts, Julian; Bos, Johannes; Eaton, Marian

    2016-01-01

    In recent decades, magnet schools have become a way for districts to provide school choice. Magnet schools are one of the many options provided to parents so that they can select a school to meet their children's educational needs and interests. After a short gap in federal grants for magnet school implementation, Congress established the current…

  18. Options for the Development of Noninvasive Glucose Monitoring: Is Nanotechnology an Option to Break the Boundaries?

    PubMed

    Thomas, Andreas; Heinemann, Lutz; Ramírez, Araceli; Zehe, Alfred

    2016-05-01

    Nowadays nanotechnology has many applications in products used in various areas of daily life; however, this technology has also an option in modern medicine and pharmacy. Therefore, this technology is also an attractive option for the field of diagnosis and treatment of diabetes. Many people with diabetes measure their blood glucose levels regularly to determine the insulin dose. Ideally glucose values would be measured noninvasively (NI). However, none of all the NI approaches studied in the past decades enabled reliable NI measurements under all daily life conditions. Particularly an unfavorable signal-to-noise ratio turned out to be problematic. Based on the known physical possibilities for NI glucose monitoring the focus of this review is on nanotechnology approaches. Functional prototypes exist for some of these that showed promising results under defined laboratory conditions, indicating a good sensitivity and selectivity for glucose. On the second hand is to optimize the technological process of manufacturing. In view of the rapid progress in micro- and nanoelectronics hopefully NI glucose monitoring systems can be developed in the near future. © 2015 Diabetes Technology Society.

  19. Public option and private profits: what do markets expect?

    PubMed

    Milani, Fabio

    2010-01-01

    The debate on US healthcare reform has largely focused on the introduction of a public health plan option. While supporters stress various beneficial effects that would arise from increased competition in the health insurance market, opponents often contend that a public plan would drive insurers out of the market and potentially lead to the 'collapse' of the private health insurance industry. To contribute to the US healthcare reform debate by inferring, from financial market data, the effect that the public option is likely to have on the private health insurance market. The study utilized daily data on the price of a security that was traded in a prediction market from June 2009 and whose pay-off was tied to the event that a federal government-run healthcare plan - the 'public option' - would be approved by 31 December 2009 (100 daily observations). These data were combined with data on stock returns of health insurance companies (1500 observations from 100 trading days and 15 companies) to evaluate the expected effect of the public option on private health insurers. The impact on hospital companies (1000 observations) was also estimated. The results suggested that daily stock returns of health insurance companies significantly responded to the changing probability regarding the public option. A 10% increase in the probability that the public option would pass, on average, reduced the stock returns of health insurance companies by 1.28% (p < 0.001). Hospital company stock returns were also affected (0.9% reduction; p < 0.001). The results reveal the market expectation of a negative effect of the public option on the value of health insurance companies. The magnitude of the effect suggests a downward adjustment in the expected profits of health insurers of around 13%, but it does not support more calamitous scenarios.

  20. Interface-Induced Phenomena in Magnetism

    PubMed Central

    Hoffmann, Axel; Tserkovnyak, Yaroslav; Beach, Geoffrey S. D.; Fullerton, Eric E.; Leighton, Chris; MacDonald, Allan H.; Ralph, Daniel C.; Arena, Dario A.; Dürr, Hermann A.; Fischer, Peter; Grollier, Julie; Heremans, Joseph P.; Jungwirth, Tomas; Kimel, Alexey V.; Koopmans, Bert; Krivorotov, Ilya N.; May, Steven J.; Petford-Long, Amanda K.; Rondinelli, James M.; Samarth, Nitin; Schuller, Ivan K.; Slavin, Andrei N.; Stiles, Mark D.; Tchernyshyov, Oleg; Thiaville, André; Zink, Barry L.

    2017-01-01

    This article reviews static and dynamic interfacial effects in magnetism, focusing on interfacially-driven magnetic effects and phenomena associated with spin-orbit coupling and intrinsic symmetry breaking at interfaces. It provides a historical background and literature survey, but focuses on recent progress, identifying the most exciting new scientific results and pointing to promising future research directions. It starts with an introduction and overview of how basic magnetic properties are affected by interfaces, then turns to a discussion of charge and spin transport through and near interfaces and how these can be used to control the properties of the magnetic layer. Important concepts include spin accumulation, spin currents, spin transfer torque, and spin pumping. An overview is provided to the current state of knowledge and existing review literature on interfacial effects such as exchange bias, exchange spring magnets, spin Hall effect, oxide heterostructures, and topological insulators. The article highlights recent discoveries of interface-induced magnetism and non-collinear spin textures, non-linear dynamics including spin torque transfer and magnetization reversal induced by interfaces, and interfacial effects in ultrafast magnetization processes. PMID:28890576

  1. The 2017 Magnetism Roadmap

    NASA Astrophysics Data System (ADS)

    Sander, D.; Valenzuela, S. O.; Makarov, D.; Marrows, C. H.; Fullerton, E. E.; Fischer, P.; McCord, J.; Vavassori, P.; Mangin, S.; Pirro, P.; Hillebrands, B.; Kent, A. D.; Jungwirth, T.; Gutfleisch, O.; Kim, C. G.; Berger, A.

    2017-09-01

    Building upon the success and relevance of the 2014 Magnetism Roadmap, this 2017 Magnetism Roadmap edition follows a similar general layout, even if its focus is naturally shifted, and a different group of experts and, thus, viewpoints are being collected and presented. More importantly, key developments have changed the research landscape in very relevant ways, so that a novel view onto some of the most crucial developments is warranted, and thus, this 2017 Magnetism Roadmap article is a timely endeavour. The change in landscape is hereby not exclusively scientific, but also reflects the magnetism related industrial application portfolio. Specifically, Hard Disk Drive technology, which still dominates digital storage and will continue to do so for many years, if not decades, has now limited its footprint in the scientific and research community, whereas significantly growing interest in magnetism and magnetic materials in relation to energy applications is noticeable, and other technological fields are emerging as well. Also, more and more work is occurring in which complex topologies of magnetically ordered states are being explored, hereby aiming at a technological utilization of the very theoretical concepts that were recognised by the 2016 Nobel Prize in Physics. Given this somewhat shifted scenario, it seemed appropriate to select topics for this Roadmap article that represent the three core pillars of magnetism, namely magnetic materials, magnetic phenomena and associated characterization techniques, as well as applications of magnetism. While many of the contributions in this Roadmap have clearly overlapping relevance in all three fields, their relative focus is mostly associated to one of the three pillars. In this way, the interconnecting roles of having suitable magnetic materials, understanding (and being able to characterize) the underlying physics of their behaviour and utilizing them for applications and devices is well illustrated, thus giving an

  2. Transcranial magnetic stimulation (TMS) in Attention Deficit Hyperactivity Disorder (ADHD).

    PubMed

    Zaman, Rashid

    2015-09-01

    Attention Deficit Hyperactivity Disorder (ADHD) is a common neuropsychiatric disorder, which affects children as well as adults and leads to significant impairment in educational, social and occupational functioning and has associated personal and societal costs. Whilst there are effective medications (mostly stimulants) as well as some psychobehavioural treatments that help alleviate symptoms of ADHD, there is still need to improve our understanding of its neurobiology as well as explore other treatment options. Transcranial Magnetic Stimulation (TMS) and repetitive transcranial magnetic stimulation (rTMS) are safe and non-invasive investigative and therapeutic tools respectively. In this short article, I will explore their potential for improving our understanding of the neurobiology of ADHD as well consider its as a possible treatment option.

  3. Survey of minor-to-moderate magnetic storm effects on ionosphere: American sector

    NASA Astrophysics Data System (ADS)

    Buresova, Dalia; Lastovicka, Jan; Chum, Jaroslav; Pezzopane, Michael; Staciarini Batista, Inez; Gularte, Erika; Novotna, Dagmar

    2014-05-01

    The paper is focused on ionospheric reaction to occasional minor-to-moderate magnetic storms above selected ionospheric stations located across the Northern and Southern America. Most of the storms analysed occurred under extremely low solar activity conditions of 2007-2009. We analysed variability of the F2 layer critical frequency foF2 and the F2 layer peak height hmF2 obtained for different latitudinal and longitudinal sectors of both hemispheres for the entire period of selected magnetic storms. Observations were compared with the effects of strong magnetic storms and with the IRI2000 outputs when STORM model option is activated. We analysed ionospheric reaction during each storm phase with main emphasis paid on the recovery phase. In general, storm recovery phase is characterized by an abatement of perturbations and a gradual return to the "ground state" of ionosphere. Magnetospheric substorms, typical for the main phase, as a rule cease during the storm recovery phase. However, observations of stormy ionosphere show significant departures from the climatology also within this phase, which are comparable with those usually observed during the storm main phase. Both positive and negative deviations of foF2 and hmF2 have been observed independent on season and location.

  4. Optimization of a Focusable and Rotatable Shear-Wave Periodic Permanent Magnet Electromagnetic Acoustic Transducers for Plates Inspection

    PubMed Central

    Qiu, Gongzhe

    2017-01-01

    Due to the symmetry of conventional periodic-permanent-magnet electromagnetic acoustic transducers (PPM EMATs), two shear (SH) waves can be generated and propagated simultaneously in opposite directions, which makes the signal recognition and interpretation complicatedly. Thus, this work presents a new SH wave PPM EMAT design, rotating the parallel line sources to realize the wave beam focusing in a single-direction. The theoretical model of distributed line sources was deduced firstly, and the effects of some parameters, such as the inner coil width, adjacent line sources spacing and the angle between parallel line sources, on SH wave focusing and directivity were studied mainly with the help of 3D FEM. Employing the proposed PPM EMATs, some experiments are carried out to verify the reliability of FEM simulation. The results indicate that rotating the parallel line sources can strength the wave on the closing side of line sources, decreasing the inner coil width and the adjacent line sources spacing can improve the amplitude and directivity of signals excited by transducers. Compared with traditional PPM EMATs, both the capacity of unidirectional excitation and directivity of the proposed PPM EMATs are improved significantly. PMID:29186790

  5. Optimization of a Focusable and Rotatable Shear-Wave Periodic Permanent Magnet Electromagnetic Acoustic Transducers for Plates Inspection.

    PubMed

    Song, Xiaochun; Qiu, Gongzhe

    2017-11-24

    Due to the symmetry of conventional periodic-permanent-magnet electromagnetic acoustic transducers (PPM EMATs), two shear (SH) waves can be generated and propagated simultaneously in opposite directions, which makes the signal recognition and interpretation complicatedly. Thus, this work presents a new SH wave PPM EMAT design, rotating the parallel line sources to realize the wave beam focusing in a single-direction. The theoretical model of distributed line sources was deduced firstly, and the effects of some parameters, such as the inner coil width, adjacent line sources spacing and the angle between parallel line sources, on SH wave focusing and directivity were studied mainly with the help of 3D FEM. Employing the proposed PPM EMATs, some experiments are carried out to verify the reliability of FEM simulation. The results indicate that rotating the parallel line sources can strength the wave on the closing side of line sources, decreasing the inner coil width and the adjacent line sources spacing can improve the amplitude and directivity of signals excited by transducers. Compared with traditional PPM EMATs, both the capacity of unidirectional excitation and directivity of the proposed PPM EMATs are improved significantly.

  6. [Therapeutic options for pressure ulcers].

    PubMed

    Damert, H-G; Meyer, F; Altmann, S

    2015-04-01

    The aim of this overview is based on remarks on the pathogenesis of and therapy for pressure ulcers and selected but representative cases to demonstrate current options of plastic coverage. As a consequence of the demographic developments, in particular, with regard to the increasing proportion of older patients as well as the advances in modern medicine, the number of multimorbid, geriatric and bedridden patients and of those with prolonged sickbed periods has been steadily growing. Therefore, partly severe manifestations of pressure ulcers at various exposed body regions can be observed in spite of the best preventive intention of care. While in the early stages rather conservative treatment is adequate, surgical intervention might become important and indispensable for a sufficient treatment in advanced stages. To facilitate basic care and to appropriately treat the infectious focus, the methods and procedures of plastic surgery can become relevant. Although there are several options and approaches existing to sanitise and cover defects of pressure ulcers, which are described within the article based on representative cases, preventive measures can still be considered the best approach. Georg Thieme Verlag KG Stuttgart · New York.

  7. 30 CFR 90.3 - Part 90 option; notice of eligibility; exercise of option.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Part 90 option; notice of eligibility; exercise of option. 90.3 Section 90.3 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF... DEVELOPMENT OF PNEUMOCONIOSIS General § 90.3 Part 90 option; notice of eligibility; exercise of option. (a...

  8. Dynamic T2-mapping during magnetic resonance guided high intensity focused ultrasound ablation of bone marrow

    NASA Astrophysics Data System (ADS)

    Waspe, Adam C.; Looi, Thomas; Mougenot, Charles; Amaral, Joao; Temple, Michael; Sivaloganathan, Siv; Drake, James M.

    2012-11-01

    Focal bone tumor treatments include amputation, limb-sparing surgical excision with bone reconstruction, and high-dose external-beam radiation therapy. Magnetic resonance guided high intensity focused ultrasound (MR-HIFU) is an effective non-invasive thermotherapy for palliative management of bone metastases pain. MR thermometry (MRT) measures the proton resonance frequency shift (PRFS) of water molecules and produces accurate (<1°C) and dynamic (<5s) thermal maps in soft tissues. PRFS-MRT is ineffective in fatty tissues such as yellow bone marrow and, since accurate temperature measurements are required in the bone to ensure adequate thermal dose, MR-HIFU is not indicated for primary bone tumor treatments. Magnetic relaxation times are sensitive to lipid temperature and we hypothesize that bone marrow temperature can be determined accurately by measuring changes in T2, since T2 increases linearly in fat during heating. T2-mapping using dual echo times during a dynamic turbo spin-echo pulse sequence enabled rapid measurement of T2. Calibration of T2-based thermal maps involved heating the marrow in a bovine femur and simultaneously measuring T2 and temperature with a thermocouple. A positive T2 temperature dependence in bone marrow of 20 ms/°C was observed. Dynamic T2-mapping should enable accurate temperature monitoring during MR-HIFU treatment of bone marrow and shows promise for improving the safety and reducing the invasiveness of pediatric bone tumor treatments.

  9. Advanced policy options to regulate sugar-sweetened beverages to support public health.

    PubMed

    Pomeranz, Jennifer L

    2012-02-01

    Consumption of sugar-sweetened beverages (SSBs) has increased worldwide. As public health studies expose the detrimental impact of SSBs, consumer protection and public health advocates have called for increased government control. A major focus has been on restricting marketing of SSBs to children, but many innovative policy options--legally defensible ways to regulate SSBs and support public health--are largely unexplored. We describe the public health, economic, and retail marketing research related to SSBs (including energy drinks). We review policy options available to governments, including mandatory factual disclosures, earmarked taxation, and regulating sales, including placement within retail and food service establishments, and schools. Our review describes recent international initiatives and classifies options available in the United States by jurisdiction (federal, state, and local) based on legal viability.

  10. 30 CFR 90.3 - Part 90 option; notice of eligibility; exercise of option.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Part 90 option; notice of eligibility; exercise... DEVELOPMENT OF PNEUMOCONIOSIS General § 90.3 Part 90 option; notice of eligibility; exercise of option. (a... meter of air. Each of these miners shall be notified in writing of eligibility to exercise the option...

  11. 30 CFR 90.3 - Part 90 option; notice of eligibility; exercise of option.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Part 90 option; notice of eligibility; exercise... DEVELOPMENT OF PNEUMOCONIOSIS General § 90.3 Part 90 option; notice of eligibility; exercise of option. (a... meter of air. Each of these miners shall be notified in writing of eligibility to exercise the option...

  12. 30 CFR 90.3 - Part 90 option; notice of eligibility; exercise of option.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Part 90 option; notice of eligibility; exercise... DEVELOPMENT OF PNEUMOCONIOSIS General § 90.3 Part 90 option; notice of eligibility; exercise of option. (a... meter of air. Each of these miners shall be notified in writing of eligibility to exercise the option...

  13. Study on Alternative Cargo Launch Options from the Lunar Surface

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cheryl A. Blomberg; Zamir A. Zulkefli; Spencer W. Rich

    In the future, there will be a need for constant cargo launches from Earth to Mars in order to build, and then sustain, a Martian base. Currently, chemical rockets are used for space launches. These are expensive and heavy due to the amount of necessary propellant. Nuclear thermal rockets (NTRs) are the next step in rocket design. Another alternative is to create a launcher on the lunar surface that uses magnetic levitation to launch cargo to Mars in order to minimize the amount of necessary propellant per mission. This paper investigates using nuclear power for six different cargo launching alternatives,more » as well as the orbital mechanics involved in launching cargo to a Martian base from the moon. Each alternative is compared to the other alternative launchers, as well as compared to using an NTR instead. This comparison is done on the basis of mass that must be shipped from Earth, the amount of necessary propellant, and the number of equivalent NTR launches. Of the options, a lunar coil launcher had a ship mass that is 12.7% less than the next best option and 17 NTR equivalent launches, making it the best of the presented six options.« less

  14. Spin-transfer torque switched magnetic tunnel junctions in magnetic random access memory

    NASA Astrophysics Data System (ADS)

    Sun, Jonathan Z.

    2016-10-01

    Spin-transfer torque (or spin-torque, or STT) based magnetic tunnel junction (MTJ) is at the heart of a new generation of magnetism-based solid-state memory, the so-called spin-transfer-torque magnetic random access memory, or STT-MRAM. Over the past decades, STT-based switchable magnetic tunnel junction has seen progress on many fronts, including the discovery of (001) MgO as the most favored tunnel barrier, which together with (bcc) Fe or FeCo alloy are yielding best demonstrated tunnel magneto-resistance (TMR); the development of perpendicularly magnetized ultrathin CoFeB-type of thin films sufficient to support high density memories with junction sizes demonstrated down to 11nm in diameter; and record-low spin-torque switching threshold current, giving best reported switching efficiency over 5 kBT/μA. Here we review the basic device properties focusing on the perpendicularly magnetized MTJs, both in terms of switching efficiency as measured by sub-threshold, quasi-static methods, and of switching speed at super-threshold, forced switching. We focus on device behaviors important for memory applications that are rooted in fundamental device physics, which highlights the trade-off of device parameters for best suitable system integration.

  15. Magnetoresistive DNA chips based on ac field focusing of magnetic labels

    NASA Astrophysics Data System (ADS)

    Ferreira, H. A.; Cardoso, F. A.; Ferreira, R.; Cardoso, S.; Freitas, P. P.

    2006-04-01

    A study was made on the sensitivity of a magnetoresistive DNA-chip platform being developed for cystic fibrosis diagnostics. The chip, comprised of an array of 2.5×80 μm2 U-shaped spin-valve sensors integrated within current line structures for magnetic label manipulation, enabled the detection at 30 Hz of 250 nm magnetic nanoparticles from 100 pM down to the pM range (or a target DNA concentration of 500 pM). It was observed that the sensor response increased linearly with label concentration. Noise spectra obtained for these sensors showed a thermal noise of 10-17 V2/Hz with a 1/f knee at 50 kHz at a 1 mA sense current, showing that lower detection limits are possible.

  16. Theory of spin and lattice wave dynamics excited by focused laser pulses

    NASA Astrophysics Data System (ADS)

    Shen, Ka; Bauer, Gerrit E. W.

    2018-06-01

    We develop a theory of spin wave dynamics excited by ultrafast focused laser pulses in a magnetic film. We take into account both the volume and surface spin wave modes in the presence of applied, dipolar and magnetic anisotropy fields and include the dependence on laser spot exposure size and magnetic damping. We show that the sound waves generated by local heating by an ultrafast focused laser pulse can excite a wide spectrum of spin waves (on top of a dominant magnon–phonon contribution). Good agreement with recent experiments supports the validity of the model.

  17. UFO-a multi-analyser option for IN12

    NASA Astrophysics Data System (ADS)

    Schmidt, Wolfgang; Rheinstädter, Maikel C.; Raymond, Stephane; Ohl, Michael

    2004-07-01

    The IN12 instrument is operated by FZ Jülich in collaboration with CEA Grenoble as a CRG-B instrument at the Institut Laue Langevin in Grenoble. As a three-axis spectrometer for cold neutrons it is dedicated for high-resolution studies of low-energy excitations. In the past years the instrument has been continuously improved and it has demonstrated its excellent performance for neutron scattering research. To meet further challenges as a state-of-the-art instrument in the next funding period we will propose to upgrade IN12 with a multi-analyser option similar to planned or existing RITA-type instruments. IN12 will then be optionally equipped with an array of individual analyser blades which can be positioned separately in order to map the scattered beam on a user-chosen path in (Q,ω)-space. We refer to this set-up as IN12-UFO (universal focusing option). Both, the feasibility and the scientific case are currently being studied. On the conference we will show details of the planned instrumental set-up and demonstrate its flexibility and multiplex advantages for specific physical applications.

  18. Wobbly Corner: Magnetism

    ERIC Educational Resources Information Center

    Corbett, Lisa; Maklad, Rania; Dunne, Mick; Grace, Pierre

    2014-01-01

    During a final seminar with BA year 4 science specialist trainee teachers, the authors posed a question about the difficulties associated with understanding magnetism. The ensuing discussion focused on a number of concerns commonly identified by students, which may also be of interest to classroom teachers teaching magnetism. Issues raised…

  19. Stability of an emittance-dominated sheet-electron beam in planar wiggler and periodic permanent magnet structures with natural focusing

    NASA Astrophysics Data System (ADS)

    Carlsten, B. E.; Earley, L. M.; Krawczyk, F. L.; Russell, S. J.; Potter, J. M.; Ferguson, P.; Humphries, S.

    2005-06-01

    A sheet-beam traveling-wave amplifier has been proposed as a high-power generator of rf from 95 to 300 GHz, using a microfabricated rf slow-wave structure [Carlsten et al., IEEE Trans. Plasma Sci. 33, 85 (2005), ITPSBD, 0093-3813, 10.1109/TPS.2004.841172], for emerging radar and communications applications. The planar geometry of microfabrication technologies matches well with the nearly planar geometry of a sheet beam, and the greater allowable beam current leads to high-peak power, high-average power, and wide bandwidths. Simulations of nominal designs using a vane-loaded waveguide as the slow-wave structure have indicated gains in excess of 1 dB/mm, with extraction efficiencies greater than 20% at 95 GHz with a 120-kV, 20-A electron beam. We have identified stable sheet-beam formation and transport as the key enabling technology for this type of device. In this paper, we describe sheet-beam transport, for both wiggler and periodic permanent magnet (PPM) magnetic field configurations, with natural (or single-plane) focusing. For emittance-dominated transport, the transverse equation of motion reduces to a Mathieu equation, and to a modified Mathieu equation for a space-charge dominated beam. The space-charge dominated beam has less beam envelope ripple than an emittance-dominated beam, but they have similar stability thresholds (defined by where the beam ripple continues to grow without bound along the transport line), consistent with the threshold predicted by the Mathieu equation. Design limits are derived for an emittance-dominated beam based on the Mathieu stability threshold. The increased beam envelope ripple for emittance-dominated transport may impact these design limits, for some transport requirements. The stability of transport in a wiggler field is additionally compromised by the beam’s increased transverse motion. Stable sheet-beam transport with natural focusing is shown to be achievable for a 120-kV, 20-A, elliptical beam with a cross section of

  20. [Arm rehabilitation : Current concepts and therapeutic options].

    PubMed

    Platz, T; Schmuck, L

    2016-10-01

    Arm paralysis after a stroke is a major cause of impairment. Presentation of therapeutic options and the efficacy in arm rehabilitation after stroke. Based on a systematic critical appraisal of randomized controlled trials (RCT) the therapeutic procedures for arm paralysis after stroke in the context of their effectiveness are introduced, including robotic therapy, mirror therapy, constraint-induced movement therapy (CIMT), arm basis training, arm ability training, neuromuscular electrical stimulation, bilateral and task-specific training, mental training and transcranial stimulation techniques, such as repetitive transcranial magnetic stimulation (rTMS) and transcranial direct current stimulation (tDCS). Several therapeutic procedures with proven efficacy are currently available for arm rehabilitation after stroke. Their differential indications are presented and associated with conclusions for clinical practice.

  1. Magnetic therapy in physics?

    NASA Astrophysics Data System (ADS)

    Welsh, Gail S.

    2000-03-01

    A critical thinking activity focused on students' understanding of magnets is described. The activity includes a short written paper about the validity of advertisements for alternative medical therapy devices based on magnets. It includes also self assessment through peer interaction.

  2. Time-dependent change of blood flow in the prostate treated with high-intensity focused ultrasound.

    PubMed

    Shoji, Sunao; Tonooka, Akiko; Hashimoto, Akio; Nakamoto, Masahiko; Tomonaga, Tetsuro; Nakano, Mayura; Sato, Haruhiro; Terachi, Toshiro; Koike, Junki; Uchida, Toyoaki

    2014-09-01

    Avascular areas on contrast-enhanced magnetic resonance imaging have been considered to be areas of localized prostate cancer successfully treated by high-intensity focused ultrasound. However, the optimal timing of magnetic resonance imaging has not been discussed. The thermal effect of high-intensity focused ultrasound is degraded by regional prostatic blood flow. Conversely, the mechanical effect of high-intensity focused ultrasound (cavitation) is not affected by blood flow, and can induce vessel damage. In this series, the longitudinal change of blood flow on contrast-enhanced magnetic resonance imaging was observed from postoperative day 1 to postoperative day 14 in 10 patients treated with high-intensity focused ultrasound. The median rates of increase in the non-enhanced volume of the whole gland, transition zone and peripheral zone from postoperative day 1 to postoperative day 14 were 36%, 39%, and 34%, respectively. In another pathological analysis of the prostate tissue of 17 patients immediately after high-intensity focused ultrasound without neoadjuvant hormonal therapy, we observed diffuse coagulative degeneration and partial non-coagulative prostate tissue around arteries with vascular endothelial cell detachment. These observations on contrast-enhanced magnetic resonance imaging support a time-dependent change of the blood flow in the prostate treated with high-intensity focused ultrasound. Additionally, our pathological findings support the longitudinal changes of these magnetic resonance imaging findings. Further large-scale studies will investigate the most appropriate timing of contrast-enhanced magnetic resonance imaging for evaluation of the effectiveness of high-intensity focused ultrasound for localized prostate cancer. © 2014 The Japanese Urological Association.

  3. Interface-induced phenomena in magnetism

    DOE PAGES

    Hellman, Frances; Hoffmann, Axel; Tserkovnyak, Yaroslav; ...

    2017-06-05

    Our article reviews static and dynamic interfacial effects in magnetism, focusing on interfacially-driven magnetic effects and phenomena associated with spin-orbit coupling and intrinsic symmetry breaking at interfaces. It provides a historical background and literature survey, but focuses on recent progress, identifying the most exciting new scientific results and pointing to promising future research directions. It starts with an introduction and overview of how basic magnetic properties are affected by interfaces, then turns to a discussion of charge and spin transport through and near interfaces and how these can be used to control the properties of the magnetic layer. Important conceptsmore » include spin accumulation, spin currents, spin transfer torque, and spin pumping. We provide an overview for the current state of knowledge and existing review literature on interfacial effects such as exchange bias, exchange spring magnets, spin Hall effect, oxide heterostructures, and topological insulators. Our article highlights recent discoveries of interface-induced magnetism and non-collinear spin textures, non-linear dynamics including spin torque transfer and magnetization reversal induced by interfaces, and interfacial effects in ultrafast magnetization processes.« less

  4. Overview of antimicrobial options for Mycoplasma pneumoniae pneumonia: focus on macrolide resistance.

    PubMed

    Cao, Bin; Qu, Jiu-Xin; Yin, Yu-Dong; Eldere, Johan Van

    2017-07-01

    Community-acquired pneumonia (CAP) is a common infectious disease affecting children and adults of any age. Mycoplasma pneumoniae has emerged as leading causative agent of CAP in some region, and the abrupt increasing resistance to macrolide that widely used for management of M. pneumoniae has reached to the level that it often leads to treatment failures. We aim to discuss the drivers for development of macrolide-resistant M. pneumoniae, antimicrobial stewardship and also the potential treatment options for patients infected with macrolide-resistant M. pneumonia. The articles in English and Chinese published in Pubmed and in Asian medical journals were selected for the review. M. pneumoniae can develop macrolide resistance by point mutations in the 23S rRNA gene. Inappropriate and overuse of macrolides for respiratory tract infections may induce the resistance rapidly. A number of countries have introduced the stewardship program for restricting the use of macrolide. Tetracyclines and fluoroquinolones are highly effective for macrolide-resistant strains, which may be the substitute in the region of high prevalence of macrolide-resistant M. pneumoniae. The problem of macrolide resistant M. pneumonia is emerging. Antibiotic stewardship is needed to inhibit the inappropriate use of macrolide and new antibiotics with a more acceptable safety profile for all ages need to be explored. © 2015 John Wiley & Sons Ltd.

  5. A range-based method to calibrate a magnetic spectrometer measuring the energy spectrum of the backward electron beam of a plasma focus.

    PubMed

    Ceccolini, E; Rocchi, F; Mostacci, D; Sumini, M; Tartari, A

    2011-08-01

    The electron beam emitted from the back of plasma focus devices is being studied as a radiation source for intraoperative radiation therapy applications. A plasma focus device is being developed for this purpose, and there is a need for characterizing its electron beam, particularly, insofar as the energy spectrum is concerned. The instrument used is a magnetic spectrometer. To calibrate this spectrometer, a procedure relying on the energy-range relation in Mylar® has been devised and applied. By measuring the transmission through increasing thicknesses of the material, electron energies could be assessed and compared to the spectrometer readings. Thus, the original calibration of the instrument has been extended to higher energies and also to better accuracy. Methods and results are presented.

  6. Surgical options for lumbosacral fusion: biomechanical stability, advantage, disadvantage and affecting factors in selecting options.

    PubMed

    Yoshihara, Hiroyuki

    2014-07-01

    Numerous surgical procedures and instrumentation techniques for lumbosacral fusion (LSF) have been developed. This is probably because of its high mechanical demand and unique anatomy. Surgical options include anterior column support (ACS) and posterior stabilization procedures. Biomechanical studies have been performed to verify the stability of those options. The options have their own advantage but also disadvantage aspects. This review article reports the surgical options for lumbosacral fusion, their biomechanical stability, advantages/disadvantages, and affecting factors in option selection. Review of literature. LSF has lots of options both for ACS and posterior stabilization procedures. Combination of posterior stabilization procedures is an option. Furthermore, combinations of ACS and posterior stabilization procedures are other options. It is difficult to make a recommendation or treatment algorithm of LSF from the current literature. However, it is important to know all aspects of the options and decision-making of surgical options for LSF needs to be tailored for each patient, considering factors such as biomechanical stress and osteoporosis.

  7. A magnetic anti-cancer compound for magnet-guided delivery and magnetic resonance imaging

    PubMed Central

    Eguchi, Haruki; Umemura, Masanari; Kurotani, Reiko; Fukumura, Hidenobu; Sato, Itaru; Kim, Jeong-Hwan; Hoshino, Yujiro; Lee, Jin; Amemiya, Naoyuki; Sato, Motohiko; Hirata, Kunio; Singh, David J.; Masuda, Takatsugu; Yamamoto, Masahiro; Urano, Tsutomu; Yoshida, Keiichiro; Tanigaki, Katsumi; Yamamoto, Masaki; Sato, Mamoru; Inoue, Seiichi; Aoki, Ichio; Ishikawa, Yoshihiro

    2015-01-01

    Research on controlled drug delivery for cancer chemotherapy has focused mainly on ways to deliver existing anti-cancer drug compounds to specified targets, e.g., by conjugating them with magnetic particles or encapsulating them in micelles. Here, we show that an iron-salen, i.e., μ-oxo N,N'- bis(salicylidene)ethylenediamine iron (Fe(Salen)), but not other metal salen derivatives, intrinsically exhibits both magnetic character and anti-cancer activity. X-Ray crystallographic analysis and first principles calculations based on the measured structure support this. It promoted apoptosis of various cancer cell lines, likely, via production of reactive oxygen species. In mouse leg tumor and tail melanoma models, Fe(Salen) delivery with magnet caused a robust decrease in tumor size, and the accumulation of Fe(Salen) was visualized by magnetic resonance imaging. Fe(Salen) is an anti-cancer compound with magnetic property, which is suitable for drug delivery and imaging. We believe such magnetic anti-cancer drugs have the potential to greatly advance cancer chemotherapy for new theranostics and drug-delivery strategies. PMID:25779357

  8. Enhanced Energy Density in Permanent Magnets using Controlled High Magnetic Field during Processing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rios, Orlando; Carter, Bill; Constantinides, Steve

    This ORNL Manufacturing Demonstraction Facility (MDF) technical collaboration focused on the use of high magnetic field processing (>2Tesla) using energy efficient large bore superconducting magnet technology and high frequency electromagnetics to improve magnet performance and reduce the energy budget associated with Alnico thermal processing. Alnico, alloys containing Al, Ni, Co and Fe, represent a class of functional nanostructured alloys, and show the greatest potential for supplementing or replacing commercial Nd-based rare-earth alloy magnets.

  9. Matriculation Evaluation: Monographs on Designs from the Local Research Options Project.

    ERIC Educational Resources Information Center

    1992

    In November 1989, nine research designs developed to assist local colleges in the evaluation of their matriculation activities were disseminated to the California community colleges. These designs, created as part of the Local Research Options Project, focused on measuring the effects of the colleges' matriculation activities on student…

  10. Magnetic nanoparticles: synthesis, functionalization, and applications in bioimaging and magnetic energy storage.

    PubMed

    Frey, Natalie A; Peng, Sheng; Cheng, Kai; Sun, Shouheng

    2009-09-01

    This tutorial review summarizes the recent advances in the chemical synthesis and potential applications of monodisperse magnetic nanoparticles. After a brief introduction to nanomagnetism, the review focuses on recent developments in solution phase syntheses of monodisperse MFe(2)O(4), Co, Fe, CoFe, FePt and SmCo(5) nanoparticles. The review further outlines the surface, structural, and magnetic properties of these nanoparticles for biomedicine and magnetic energy storage applications.

  11. Stability and refrigeration of magnet cryosystems near 1.8 K using the thermomechanical effect

    NASA Technical Reports Server (NTRS)

    Frederking, T. H. K.; Chen, W. E. W.; Caspi, S.

    1987-01-01

    Magnet cryosystem options utilizing the thermomechanical effect of He II and the mechano-caloric effect for refrigeration (referred to as vortex refrigeration) are examined. The performance of the existing He II magnet refrigeration system is briefly reviewed, with attention given to superleak properties, vortex shedding, heat input, and thermodynamic cycle. It is concluded that the possibilities of magnet heat leak use for energetics and stability improvements are promising when He II is selected as magnet coolant.

  12. Comparison of magnetic resonance imaging-compatible optical detectors for in-magnet tissue spectroscopy: photodiodes versus silicon photomultipliers

    PubMed Central

    El-Ghussein, Fadi; Jiang, Shudong; Pogue, Brian W.; Paulsen, Keith D.

    2014-01-01

    Abstract. Tissue spectroscopy inside the magnetic resonance imaging (MRI) system adds a significant value by measuring fast vascular hemoglobin responses or completing spectroscopic identification of diagnostically relevant molecules. Advances in this type of spectroscopy instrumentation have largely focused on fiber coupling into and out of the MRI; however, nonmagnetic detectors can now be placed inside the scanner with signal amplification performed remotely to the high field environment for optimized light detection. In this study, the two possible detector options, such as silicon photodiodes (PD) and silicon photomultipliers (SiPM), were systematically examined for dynamic range and wavelength performance. Results show that PDs offer 108 (160 dB) dynamic range with sensitivity down to 1 pW, whereas SiPMs have 107 (140 dB) dynamic range and sensitivity down to 10 pW. A second major difference is the spectral sensitivity of the two detectors. Here, wavelengths in the 940 nm range are efficiently captured by PDs (but not SiPMs), likely making them the superior choice for broadband spectroscopy guided by MRI. PMID:25006986

  13. A permanent magnet system for Kibble balances

    NASA Astrophysics Data System (ADS)

    Li, Shisong; Bielsa, Franck; Stock, Michael; Kiss, Adrien; Fang, Hao

    2017-10-01

    The magnet is one of the fundamental elements in Kibble balances. The Kibble balance group at the Bureau International des Poids et Mesures (BIPM) proposed a permanent magnet with a radial field, which has been widely employed in other Kibble balance experiments. In this paper, we discuss a different method of operation for the BIPM-type magnet, i.e. only the lower half of the magnetic circuit is closed. The merit of such a magnet is its convenience for opening the air gap and adjusting the coil. A disadvantage is that it can yield a lower and sloped magnetic field profile with less shielding. In the approach described, high permeability yokes are used to flatten the magnetic profile, which has proven to be a novel and convenient approach for removing the nonuniformity of the magnetic profile due to magnet magnetization asymmetries. The performance of the half-closed BIPM magnet is evaluated using experimental measurements. The results show that the half-closed magnetic circuit retains most of the main features of the fully-closed magnet and is a good option for the early stages of Kibble balance operations. In addition, the profile change due to the coil current is predicted and experimentally verified with a bifilar coil. Related systematic effects are discussed for the Planck constant measurement.

  14. Engineering of the Magnetized Target Fusion Propulsion System

    NASA Technical Reports Server (NTRS)

    Statham, G.; White, S.; Adams, R. B.; Thio, Y. C. F.; Santarius, J.; Alexander, R.; Fincher, S.; Polsgrove, T.; Chapman, J.; Philips, A.

    2002-01-01

    Engineering details are presented for a magnetized target fusion (MTF) propulsion system designed to support crewed missions to the outer solar system. Structural, thermal and radiation-management design details are presented. Propellant storage and supply options are also discussed and a propulsion system mass estimate is given.

  15. Thermal fixation of swine liver tissue after magnetic resonance-guided high-intensity focused ultrasound ablation.

    PubMed

    Courivaud, Frédéric; Kazaryan, Airazat M; Lund, Alice; Orszagh, Vivian C; Svindland, Aud; Marangos, Irina Pavlik; Halvorsen, Per Steinar; Jebsen, Peter; Fosse, Erik; Hol, Per Kristian; Edwin, Bjørn

    2014-07-01

    The aim of this study was to investigate experimental conditions for efficient and controlled in vivo liver tissue ablation by magnetic resonance (MR)-guided high-intensity focused ultrasound (HIFU) in a swine model, with the ultimate goal of improving clinical treatment outcome. Histological changes were examined both acutely (four animals) and 1 wk after treatment (five animals). Effects of acoustic power and multiple sonication cycles were investigated. There was good correlation between target size and observed ablation size by thermal dose calculation, post-procedural MR imaging and histopathology, when temperature at the focal point was kept below 90°C. Structural histopathology investigations revealed tissue thermal fixation in ablated regions. In the presence of cavitation, mechanical tissue destruction occurred, resulting in an ablation larger than the target. Complete extra-corporeal MR-guided HIFU ablation in the liver is feasible using high acoustic power. Nearby large vessels were preserved, which makes MR-guided HIFU promising for the ablation of liver tumors adjacent to large veins. Copyright © 2014 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  16. Option price and market instability

    NASA Astrophysics Data System (ADS)

    Baaquie, Belal E.; Yu, Miao

    2017-04-01

    An option pricing formula, for which the price of an option depends on both the value of the underlying security as well as the velocity of the security, has been proposed in Baaquie and Yang (2014). The FX (foreign exchange) options price was empirically studied in Baaquie et al., (2014), and it was found that the model in general provides an excellent fit for all strike prices with a fixed model parameters-unlike the Black-Scholes option price Hull and White (1987) that requires the empirically determined implied volatility surface to fit the option data. The option price proposed in Baaquie and Cao Yang (2014) did not fit the data during the crisis of 2007-2008. We make a hypothesis that the failure of the option price to fit data is an indication of the market's large deviation from its near equilibrium behavior due to the market's instability. Furthermore, our indicator of market's instability is shown to be more accurate than the option's observed volatility. The market prices of the FX option for various currencies are studied in the light of our hypothesis.

  17. Self-sustained focusing of high-density streaming plasma

    NASA Astrophysics Data System (ADS)

    Bugaev, A.; Dobrovolskiy, A.; Goncharov, A.; Gushenets, V.; Litovko, I.; Naiko, I.; Oks, E.

    2017-01-01

    We describe our observations of the transport through an electrostatic plasma lens of a wide-aperture, high-current, low energy, metal-ion plasma flow produced by a cathodic arc discharge. The lens input aperture was 80 mm, the length of the lens was 140 mm, and there were three electrostatic ring electrodes located in a magnetic field formed by permanent magnets. The lens outer electrodes were grounded and the central electrode was biased up to -3 kV. The plasma was a copper plasma with directed (streaming) ion energy 20-40 eV, and the equivalent ion current was up to several amperes depending on the potential applied to the central lens electrode. We find that when the central lens electrode is electrically floating, the current density of the plasma flow at the lens focus increases by up to 40%-50%, a result that is in good agreement with a theoretical treatment based on plasma-optical principles of magnetic insulation of electrons and equipotentialization along magnetic field lines. When the central lens electrode is biased negatively, an on-axis stream of energetic electrons is formed, which can also provide a mechanism for focusing of the plasma flow. Optical emission spectra under these conditions show an increase in intensity of lines corresponding to both copper atoms and singly charged copper ions, indicating the presence of fast electrons within the lens volume. These energetic electrons, as well as accumulating on-axis and providing ion focusing, can also assist in reducing the microdroplet component in the dense, low-temperature, metal plasma.

  18. Efficient Trajectory Options Allocation for the Collaborative Trajectory Options Program

    NASA Technical Reports Server (NTRS)

    Rodionova, Olga; Arneson, Heather; Sridhar, Banavar; Evans, Antony

    2017-01-01

    The Collaborative Trajectory Options Program (CTOP) is a Traffic Management Initiative (TMI) intended to control the air traffic flow rates at multiple specified Flow Constrained Areas (FCAs), where demand exceeds capacity. CTOP allows flight operators to submit the desired Trajectory Options Set (TOS) for each affected flight with associated Relative Trajectory Cost (RTC) for each option. CTOP then creates a feasible schedule that complies with capacity constraints by assigning affected flights with routes and departure delays in such a way as to minimize the total cost while maintaining equity across flight operators. The current version of CTOP implements a Ration-by-Schedule (RBS) scheme, which assigns the best available options to flights based on a First-Scheduled-First-Served heuristic. In the present study, an alternative flight scheduling approach is developed based on linear optimization. Results suggest that such an approach can significantly reduce flight delays, in the deterministic case, while maintaining equity as defined using a Max-Min fairness scheme.

  19. Magnetic resonance-guided focused ultrasound treatment of facet joint pain: summary of preclinical phase

    PubMed Central

    2014-01-01

    Study design A phantom experiment, two thermocouple experiments, three in vivo pig experiments, and a simulated treatment on a healthy human volunteer were conducted to test the feasibility, safety, and efficacy of magnetic resonance-guided focused ultrasound (MRgFUS) for treating facet joint pain. Objective The goal of the current study was to develop a novel method for accurate and safe noninvasive facet joint ablation using MRgFUS. Summary of background data Facet joints are a common source of chronic back pain. Direct facet joint interventions include medial branch nerve ablation and intra-articular injections, which are widely used, but limited in the short and long term. MRgFUS is a breakthrough technology that enables accurate delivery of high-intensity focused ultrasound energy to create a localized temperature rise for tissue ablation, using MR guidance for treatment planning and real-time feedback. Methods We validated the feasibility, safety, and efficacy of MRgFUS for facet joint ablation using the ExAblate 2000® System (InSightec Ltd., Tirat Carmel, Israel) and confirmed the system's ability to ablate the edge of the facet joint and all terminal nerves innervating the joint. A phantom experiment, two thermocouple experiments, three in vivo pig experiments, and a simulated treatment on a healthy human volunteer were conducted. Results The experiments showed that targeting the facet joint with energies of 150–450 J provides controlled and accurate heating at the facet joint edge without penetration to the vertebral body, spinal canal, or root foramina. Treating with reduced diameter of the acoustic beam is recommended since a narrower beam improves access to the targeted areas. Conclusions MRgFUS can safely and effectively target and ablate the facet joint. These results are highly significant, given that this is the first study to demonstrate the potential of MRgFUS to treat facet joint pain. PMID:24921048

  20. Comparing the ability of OPTION(12) and OPTION(5) to assess shared decision-making in genetic counselling.

    PubMed

    Vortel, Martina A; Adam, Shelin; Port-Thompson, Ashley V; Friedman, Jan M; Grande, Stuart W; Birch, Patricia H

    2016-10-01

    OPTION(12) is the most widely used tool to measure shared decision-making (SDM) in health care. A newer scale, OPTION(5), has been proposed as a more parsimonious measure that better addresses core concepts of SDM. This study compares OPTION(5) to OPTION(12) in prenatal genetic counselling. Two raters independently used OPTION(12) and OPTION(5) to score 27 clinical encounters between genetic counsellors (GC) and women with pregnancies at increased risk for genetic conditions. Global and item scores on the two instruments were compared to test concurrent validity and to identify usability in this context. Inter-rater reliability was also assessed for both instruments. Mean scores for OPTION(12) were 43.8 (SD=9.7), and for OPTION(5) were=60.6 (SD=12.5). The correlation between OPTION(12) and OPTION(5) scores was r=0.70. Inter-rater reliability was 0.70 and 0.85 for OPTION(12) and OPTION(5) respectively, however mean inter-rater reliability for individual items was 0.31 and 0.63 for OPTION(12) and OPTION(5) respectively. GCs exhibit SDM as measured by both OPTION instruments. OPTION(5) exhibits improved psychometric performance relative to OPTION(12), and more specifically targets the core constructs of SDM. However, refinement of OPTION instruments or manuals is needed to improve reliability and validity in GC assessment. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  1. Implementation of power barrier option valuation

    NASA Astrophysics Data System (ADS)

    Cahyani, Agatha C. P.; Sumarti, Novriana

    2015-09-01

    Options are financial instruments that can be utilized to reduce risk in stock investment. Barrier options are one of the major types of options actively used in financial markets where its life period depends on the path of the underlying stock prices. The features of the barrier option can be used to modify other types of options. In this research, the barrier option will be implemented into power option, so it is called power barrier option. This option is an extension of the vanilla barrier options where the Call payoff being considered is defined as P C =max (STβ-Kβ,0 ) , and the Put payoff being considered is defined as P P =max (Kβ-STβ,0 ) . Here β > 0 and β ≠ 1, K is the strike price of the option, and ST is the price of the underlying stock at time maturity T. In this paper, we generate the prices of stock using binomial method which is adjusted to the power option. In the conclusion, the price of American power barrier option is more expensive than the price of European power barrier option.

  2. Contribution of Sudanese medical diaspora to the healthcare delivery system in Sudan: exploring options and barriers.

    PubMed

    Abdalla, Fayrouz Mohammed; Omar, Maye Abu; Badr, Elsheikh Elsiddig

    2016-06-30

    Medical diaspora options, including the engagement of expatriate physicians in development efforts within their home country, are being called for to reverse the effects of brain drain from developing countries. This paper presents the results of a study exploring the potential contributions for the Sudanese Medial Diaspora Options to the healthcare delivery system (HCDS) in Sudan, focusing on the options of temporal and permanent returns and the likely obstacles faced in their implementation. This was a cross-sectional study using a mixed methods design including quantitative and qualitative approaches. For the quantitative approach, the study, which focused on the possible contribution of the diaspora to healthcare delivery in Sudan, was based on an online survey using random purposive and snowballing sampling techniques involving 153 Sudanese physicians working in Saudi Arabia and other Gulf States, the United Kingdom, the Republic of Ireland, and the United States of America. The qualitative approach involved in-depth interviews with returnee physicians and key informants in Sudan, focusing on the return experiences, the barriers for return, and the options to improve future contributions. Despite contributions of the Sudanese medical diaspora being of a small scale considering the size of the phenomenon, as well as infrequent and not appropriately organized, their inputs to academia and the links built with overseas institutions and specialist clinical services were nevertheless remarkable. The main barrier to temporal return was inappropriate organization by the local counterparts, while those for permanent return of physicians were poor work environment, insufficient financial payment, unsecured accommodation, and offspring education. The study identified short-term return as a feasible option considering the country's current conditions. Proper coordination mechanisms for short-term returns and facilitation of permanent return through stakeholders

  3. Selected Energy Conservation Options for Homeowners: Options, Expenses and Payoffs.

    ERIC Educational Resources Information Center

    Lengyel, Dorothy L.; And Others

    This publication is a check list for homeowners and renters to help them reduce energy costs. The list consists of 126 energy conservation options. These options range from "change clothes instead of adjusting thermostat" and "air conditioners turned off when not home" to "use sink stopper" and "weatherstripping…

  4. The predictive performance of a path-dependent exotic-option credit risk model in the emerging market

    NASA Astrophysics Data System (ADS)

    Chen, Dar-Hsin; Chou, Heng-Chih; Wang, David; Zaabar, Rim

    2011-06-01

    Most empirical research of the path-dependent, exotic-option credit risk model focuses on developed markets. Taking Taiwan as an example, this study investigates the bankruptcy prediction performance of the path-dependent, barrier option model in the emerging market. We adopt Duan's (1994) [11], (2000) [12] transformed-data maximum likelihood estimation (MLE) method to directly estimate the unobserved model parameters, and compare the predictive ability of the barrier option model to the commonly adopted credit risk model, Merton's model. Our empirical findings show that the barrier option model is more powerful than Merton's model in predicting bankruptcy in the emerging market. Moreover, we find that the barrier option model predicts bankruptcy much better for highly-leveraged firms. Finally, our findings indicate that the prediction accuracy of the credit risk model can be improved by higher asset liquidity and greater financial transparency.

  5. Magnetic Resonance-Guided High-Intensity Focused Ultrasound (MRgHIFU) Treatment of Symptomatic Uterine Fibroids: An Evidence-Based Analysis.

    PubMed

    Pron, G

    2015-01-01

    Magnetic resonance-guided high-intensity focused ultrasound (MRgHIFU) is a noninvasive uterine-preserving treatment alternative to hysterectomy for women with symptomatic uterine leiomyomas (fibroids). Uterine fibroids commonly occur, have a broad impact on women's health and lifestyle, continue to be the main indication for hysterectomy, and represent a costly public health burden. The objectives of the analysis were to evaluate patients' eligibility for MRgHIFU treatment of symptomatic uterine fibroids and the technical success, safety, effectiveness, and durability of this treatment. The review also compared the safety and effectiveness of MRgHIFU with other minimally invasive uterine-preserving treatments and surgeries for uterine fibroids. A literature search was performed on March 27, 2014, using Ovid MEDLINE, Ovid MEDLINE In-Process and Other Non-Indexed Citations, Ovid EMBASE, EBSCO Cumulative Index to Nursing & Allied Health Literature (CINAHL), and EBM Reviews, for studies published from January 1, 2000, to March 27, 2014. The evidence review identified 2 systematic reviews, 2 RCTs, 45 cohort study reports, and 19 case reports involving HIFU treatment of symptomatic uterine fibroids. Eligibility for MRgHIFU treatment was variable, ranging from 14% to 74%. In clinical cohort studies involving 1,594 patients, 26 major complications (1.6%) were reported. MRgHIFU resulted in statistically and clinically significant reductions in fibroid-related symptoms in studies conducted in 10 countries, although few involved follow-up longer than 1 year. Retreatment rates following MRgHIFU were higher in early clinical studies involving regulated restrictions in the extent of fibroid ablation than in later reports involving near-complete ablation. Emergent interventions, however, were rare. Although a desire for fertility was an exclusion criteria for treatment, spontaneous term pregnancies did occur following HIFU. There were no randomized trials comparing MRgHIFU and

  6. Evaluating options for balancing the water-electricity nexus in California: part 1--securing water availability.

    PubMed

    Tarroja, Brian; AghaKouchak, Amir; Sobhani, Reza; Feldman, David; Jiang, Sunny; Samuelsen, Scott

    2014-11-01

    The technical potential and effectiveness of different water supply options for securing water availability in a large-scale, interconnected water supply system under historical and climate-change augmented inflow and demand conditions were compared. Part 1 of the study focused on determining the scale of the options required to secure water availability and compared the effectiveness of different options. A spatially and temporally resolved model of California's major surface reservoirs was developed, and its sensitivity to urban water conservation, desalination, and water reuse was examined. Potential capacities of the different options were determined. Under historical (baseline) hydrology conditions, many individual options were found to be capable of securing water availability alone. Under climate change augment conditions, a portfolio approach was necessary. The water savings from many individual options other than desalination were insufficient in the latter, however, relying on seawater desalination alone requires extreme capacity installations which have energy, brine disposal, management, and cost implications. The importance of identifying and utilizing points of leverage in the system for choosing where to deploy different options is also demonstrated. Copyright © 2014 Elsevier B.V. All rights reserved.

  7. A prototype software methodology for the rapid evaluation of biomanufacturing process options.

    PubMed

    Chhatre, Sunil; Francis, Richard; O'Donovan, Kieran; Titchener-Hooker, Nigel J; Newcombe, Anthony R; Keshavarz-Moore, Eli

    2007-10-01

    A three-layered simulation methodology is described that rapidly evaluates biomanufacturing process options. In each layer, inferior options are screened out, while more promising candidates are evaluated further in the subsequent, more refined layer, which uses more rigorous models that require more data from time-consuming experimentation. Screening ensures laboratory studies are focused only on options showing the greatest potential. To simplify the screening, outputs of production level, cost and time are combined into a single value using multi-attribute-decision-making techniques. The methodology was illustrated by evaluating alternatives to an FDA (U.S. Food and Drug Administration)-approved process manufacturing rattlesnake antivenom. Currently, antivenom antibodies are recovered from ovine serum by precipitation/centrifugation and proteolyzed before chromatographic purification. Alternatives included increasing the feed volume, replacing centrifugation with microfiltration and replacing precipitation/centrifugation with a Protein G column. The best alternative used a higher feed volume and a Protein G step. By rapidly evaluating the attractiveness of options, the methodology facilitates efficient and cost-effective process development.

  8. Optimization study on the magnetic field of superconducting Halbach Array magnet

    NASA Astrophysics Data System (ADS)

    Shen, Boyang; Geng, Jianzhao; Li, Chao; Zhang, Xiuchang; Fu, Lin; Zhang, Heng; Ma, Jun; Coombs, T. A.

    2017-07-01

    This paper presents the optimization on the strength and homogeneity of magnetic field from superconducting Halbach Array magnet. Conventional Halbach Array uses a special arrangement of permanent magnets which can generate homogeneous magnetic field. Superconducting Halbach Array utilizes High Temperature Superconductor (HTS) to construct an electromagnet to work below its critical temperature, which performs equivalently to the permanent magnet based Halbach Array. The simulations of superconducting Halbach Array were carried out using H-formulation based on B-dependent critical current density and bulk approximation, with the FEM platform COMSOL Multiphysics. The optimization focused on the coils' location, as well as the geometry and numbers of coils on the premise of maintaining the total amount of superconductor. Results show Halbach Array configuration based superconducting magnet is able to generate the magnetic field with intensity over 1 Tesla and improved homogeneity using proper optimization methods. Mathematical relation of these optimization parameters with the intensity and homogeneity of magnetic field was developed.

  9. Microscopic Magnetic Properties of the Itinerant Metamagnet UCoAl by X-ray Magnetic Circular Dichroism

    NASA Astrophysics Data System (ADS)

    Combier, Tristan; Palacio-Morales, Alexandra; Sanchez, Jean-Pierre; Wilhelm, Fabrice; Pourret, Alexandre; Brison, Jean-Pascal; Aoki, Dai; Rogalev, Andrei

    2017-02-01

    The itinerant metamagnet UCoAl has been investigated by high field X-ray magnetic circular dichroism (XMCD) at the U M4,5 and Co K edges. The orbital and spin moments of U at 2.1 K for H || c applied below and above the first order metamagnetic transition field (HM) have been determined. The magnetism of UCoAl is dominated by the U moment. There is no evidence for any change of the orbital to spin moment ratio (˜-2.05) across HM and within the ferromagnetic phase up to 17 T. The possibility of a Fermi surface reconstruction at HM remains an open option. XMCD at the Co K-edge reveals the presence of a small Co 4p-orbital moment parallel to the macroscopic magnetization. In addition, the Co 3d-moment is estimated to be at most 0.1 μB at 17 T. The similar field dependence of the U and Co magnetizations indicates that the Co moment is induced by the U moment.

  10. Engineered, thermoresponsive, magnetic nanocarriers of oligo(ethylene glycol)-methacrylate-based biopolymers

    NASA Astrophysics Data System (ADS)

    McCallister, Thomas; Gidney, Elwood; Adams, Devin; Diercks, David R.; Ghosh, Santaneel

    2014-11-01

    Engineered magnetic nanocarriers offer attractive options for implementing novel therapeutic solutions in biomedical research; however lack of biocompatibility and external tunability have prevented a biomedical breakthrough. Here we report multifunctional, magnetic nanospheres with tailored size, volumetric transition range, and magnetic properties based on biocompatible, thermo-responsive oligo(ethylene glycol) methacrylate biopolymers. Precise control of the nanosphere size in the range 100-300 nm, coupled with a higher and broader volumetric transition range (32-42 °C), is ideal for various biomedical applications. More importantly, super-paramagnetic behavior of the nanocarriers, even after polymer shell shrinkage, indicates stable and easily controllable loss mechanisms under exposure to an ac magnetic field.

  11. Magnetized Neutron Stars in the Interstellar Medium

    NASA Astrophysics Data System (ADS)

    Toropina, O. D.; Romanova, M. M.; Lovelace, R. V. E.

    2014-09-01

    We investigate the propagation of magnetized, isolated old neutron stars through the interstellar medium. We performed axisymmetric, non-relativistic magnetohydrodynamic simulations of the supersonic motion of neutron star with dipole magnetic field aligned with its velocity through the interstellar medium (ISM). We consider two cases: (1) where the accretion radius is larger than Alfvén radius, i.e. Racc>>RA and gravitational focusing is important; and (2) where Racc<magnetized star interacts with the ISM as a “georotator”, without significant gravitational focusing. In the first case we observe Bondi-Hoyle accretion onto an isolated magnetized neutron star. In the second case magnetic field lines are stretched downwind from the star and form a hollow elongated magnetotail. Reconnection of the magnetic field is observed in the tail which may lead to acceleration of particles.

  12. Enhancement and Passive Acoustic Mapping of Cavitation from Fluorescently Tagged Magnetic Resonance-Visible Magnetic Microbubbles In Vivo.

    PubMed

    Crake, Calum; Owen, Joshua; Smart, Sean; Coviello, Christian; Coussios, Constantin-C; Carlisle, Robert; Stride, Eleanor

    2016-12-01

    Previous work has indicated the potential of magnetically functionalized microbubbles to localize and enhance cavitation activity under focused ultrasound exposure in vitro. The aim of this study was to investigate magnetic targeting of microbubbles for promotion of cavitation in vivo. Fluorescently labelled magnetic microbubbles were administered intravenously in a murine xenograft model. Cavitation was induced using a 0.5-MHz focused ultrasound transducer at peak negative focal pressures of 1.2-2.0 MPa and monitored in real-time using B-mode imaging and passive acoustic mapping. Magnetic targeting was found to increase the amplitude of the cavitation signal by approximately 50% compared with untargeted bubbles. Post-exposure magnetic resonance imaging indicated deposition of magnetic nanoparticles in tumours. Magnetic targeting was similarly associated with increased fluorescence intensity in the tumours after the experiments. These results suggest that magnetic targeting could potentially be used to improve delivery of cavitation-mediated therapy and that passive acoustic mapping could be used for real-time monitoring of this process. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.

  13. Energy Options: A Curriculum Guide. Curriculum Resources for the Alaskan Environment.

    ERIC Educational Resources Information Center

    Pfisterer, William, Ed.

    The nine units in the curriculum guide on energy options focus on energy from coal, the sun, petroleum, the wind, water, and trees; and on heat pumps, energy conservation, and agriculture and energy. The units are comprised of from two to seven lessons. Each lesson contains objectives, approximate time, procedure, evaluation questions or methods,…

  14. Ion heating in a plasma focus

    NASA Technical Reports Server (NTRS)

    Hohl, F.; Gary, S. P.

    1974-01-01

    Ion acceleration and heating in a plasma focus were investigated by the numerical integration of the three-dimensional equations of motion. The electric and magnetic fields given were derived from experimental data. The results obtained show that during the collapse phase of focus formation, ions are efficiently heated to temperatures of several keV. During the phase of rapid current reduction, ions are accelerated to large velocities in the axial direction. The results obtained with the model are in general agreement with experimental results.

  15. Palliative Care Options for a Young Adult Patient with a Diffuse Intrinsic Pontine Glioma.

    PubMed

    Sison, Julian; Tran, Hung; Margol, Ashley; Tiwari, Nishant; Garcia, Karla M; Cotter, Jennifer; Kiehna, Erin; Olch, Arthur J; Wong, Kenneth

    2017-08-18

    Diffuse intrinsic pontine gliomas (DIPGs) are rare but devastating brain tumors that occur primarily in children. These gliomas have poor prognoses and present options focus on palliation of symptoms and prolongation of life. Here, we present a case of a 16-year-old female diagnosed with a DIPG whose age group has been mostly left out of discussions regarding psychosocial support options. This report is meant to start a conversation about the different support options available at our institution that have shown promising results in the literature for palliative care applications. These options can include camps for patients with brain tumors, psychological counseling, the Ronald McDonald House, and other psychosocial programs. Many of these programs can be tailored to meet the specific needs of adolescent and young adult (AYA) patients and will hopefully be integrated into a comprehensive palliative care regimen in future studies.

  16. Planar-focusing cathodes.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lewellen, J. W.; Noonan, J.; Accelerator Systems Division

    2005-01-01

    Conventional {pi}-mode rf photoinjectors typically use magnetic solenoids for emittance compensation. This provides independent focusing strength but can complicate rf power feed placement, introduce asymmetries (due to coil crossovers), and greatly increase the cost of the photoinjector. Cathode-region focusing can also provide for a form of emittance compensation. Typically this method strongly couples focusing strength to the field gradient on the cathode, however, and usually requires altering the longitudinal position of the cathode to change the focusing. We propose a new method for achieving cathode-region variable-strength focusing for emittance compensation. The new method reduces the coupling to the gradient onmore » the cathode and does not require a change in the longitudinal position of the cathode. Expected performance for an S-band system is similar to conventional solenoid-based designs. This paper presents the results of rf cavity and beam dynamics simulations of the new design. We have proposed a method for performing emittance compensation using a cathode-region focusing scheme. This technique allows the focusing strength to be adjusted somewhat independently of the on-axis field strength. Beam dynamics calculations indicate performance should be comparable to presently in-use emittance compensation schemes, with a simpler configuration and fewer possibilities for emittance degradation due to the focusing optics. There are several potential difficulties with this approach, including cathode material selection, cathode heating, and peak fields in the gun. We hope to begin experimenting with a cathode of this type in the near future, and several possibilities exist for reducing the peak gradients to more acceptable levels.« less

  17. Mitigation options for the industrial sector in Egypt

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gelil, I.A.; El-Touny, S.; Korkor, H.

    1996-12-31

    Though its contribution to the global Greenhouse gases emission is relatively small, Egypt has signed and ratified the United Nations Framework Convention on Climate Change (UN FCCC) and has been playing an active role in the international efforts to deal with such environmental challenges. Energy efficiency has been one of the main strategies that Egypt has adopted to improve environmental quality and enhance economic competitiveness. This paper highlights three initiatives currently underway to improve energy efficiency of the Egyptian industry. The first is a project that has been recently completed by OECP to assess potential GHG mitigation options available inmore » Egypt`s oil refineries. The second initiative is an assessment of GHG mitigation potential in the Small and Medium size Enterprises (SME) in the Mediterranean city of Alexandria. The third one focuses on identifying demand side management options in some industrial electricity consumers in the same city.« less

  18. Angina pectoris: current therapy and future treatment options.

    PubMed

    Parikh, Raj; Kadowitz, Philip J

    2014-02-01

    Angina pectoris is the consequence of an inequality between the demand and supply of blood to the heart. Angina manifests itself as chest pain or discomfort and is a common complaint of patients in the hospital and in the clinic. There are, in fact, roughly half a million new cases of angina per year. Chest pain, while having many etiologies, is generally considered to be most lethal when related to a cardiac cause. In this review, the authors outline the current medical and surgical therapies that are used in the management of angina. Highlights of the various clinical trials that have assisted in the investigation of these therapies are summarized also. Then, the authors provide a focused review of the novel therapy options for angina that are currently being explored. From new medical treatments to revised surgical techniques to the discovery of stem cell therapy, many innovative options are being investigated for the treatment of angina.

  19. Pulsed-focusing recirculating linacs for muon acceleration

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Johnson, Rolland

    2014-12-31

    Since the muon has a short lifetime, fast acceleration is essential for high-energy applications such as muon colliders, Higgs factories, or neutrino factories. The best one can do is to make a linear accelerator with the highest possible accelerating gradient to make the accelerating time as short as possible. However, the cost of such a single linear accelerator is prohibitively large due to expensive power sources, cavities, tunnels, and related infrastructure. As was demonstrated in the Thomas Jefferson Accelerator Facility (Jefferson Lab) Continuous Electron Beam Accelerator Facility (CEBAF), an elegant solution to reduce cost is to use magnetic return arcsmore » to recirculate the beam through the accelerating RF cavities many times, where they gain energy on each pass. In such a Recirculating Linear Accelerator (RLA), the magnetic focusing strength diminishes as the beam energy increases in a conventional linac that has constant strength quadrupoles. After some number of passes the focusing strength is insufficient to keep the beam from going unstable and being lost. In this project, the use of fast pulsed quadrupoles in the linac sections was considered for stronger focusing as a function of time to allow more successive passes of a muon beam in a recirculating linear accelerator. In one simulation, it was shown that the number of passes could be increased from 8 to 12 using pulsed magnet designs that have been developed and tested. This could reduce the cost of linac sections of a muon RLA by 8/12, where more improvement is still possible. The expense of a greater number of passes and corresponding number of return arcs was also addressed in this project by exploring the use of ramped or FFAG-style magnets in the return arcs. A better solution, invented in this project, is to use combined-function dipole-quadrupole magnets to simultaneously transport two beams of different energies through one magnet string to reduce costs of return arcs by almost a

  20. Compact and tunable focusing device for plasma wakefield acceleration

    NASA Astrophysics Data System (ADS)

    Pompili, R.; Anania, M. P.; Chiadroni, E.; Cianchi, A.; Ferrario, M.; Lollo, V.; Notargiacomo, A.; Picardi, L.; Ronsivalle, C.; Rosenzweig, J. B.; Shpakov, V.; Vannozzi, A.

    2018-03-01

    Plasma wakefield acceleration, either driven by ultra-short laser pulses or electron bunches, represents one of the most promising techniques able to overcome the limits of conventional RF technology and allows the development of compact accelerators. In the particle beam-driven scenario, ultra-short bunches with tiny spot sizes are required to enhance the accelerating gradient and preserve the emittance and energy spread of the accelerated bunch. To achieve such tight transverse beam sizes, a focusing system with short focal length is mandatory. Here we discuss the development of a compact and tunable system consisting of three small-bore permanent-magnet quadrupoles with 520 T/m field gradient. The device has been designed in view of the plasma acceleration experiments planned at the SPARC_LAB test-facility. Being the field gradient fixed, the focusing is adjusted by tuning the relative position of the three magnets with nanometer resolution. Details about its magnetic design, beam-dynamics simulations, and preliminary results are examined in the paper.

  1. 32 CFR 48.201 - Options.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 32 National Defense 1 2010-07-01 2010-07-01 false Options. 48.201 Section 48.201 National Defense...'S FAMILY PROTECTION PLAN Election of Options § 48.201 Options. As provided in § 48.203, a member may... amount equal to such 121/2 per centum. (a) Option 1 is an annuity payable to or on behalf of his widow...

  2. PANDAS: A systematic review of treatment options.

    PubMed

    Farhood, Zachary; Ong, Adrian A; Discolo, Christopher M

    2016-10-01

    Pediatric Autoimmune Neuropsychiatric Disorder Associated with Streptococcus (PANDAS) is a rare but important condition for pediatric otolaryngologists to recognize. Several treatment options exist including tonsillectomy, antibiotic treatment/prophylaxis, intravenous immunoglobulin (IVIG), and psychiatric medications/therapy. A systematic review of the PubMed, EMBASE, and Scopus databases was performed searching for articles that focused exclusively on the aforementioned treatment modalities in the PANDAS population. Review articles, single patient case reports, and studies examining the natural history or diagnostic strategies were excluded. Five articles regarding tonsillectomy treatments with level of evidence (LOE) 4 were found but no clear benefit could be determined. Three articles were selected involving the use of antibiotic therapy. One prospective study and one double-blind randomized control trial (DB RCT) supported the use of antibiotics but a separate DB RCT showed no benefit. Two selected articles described the use of IVIG: one unblinded RCT and one retrospective study. One prospective study on cognitive-behavioral therapy (CBT) showed benefit in PANDAS. There is a paucity of high-level studies regarding this rare disorder and no hard treatment recommendations can be made. Tonsillectomy should only be performed in those who are surgical candidates based on current published guidelines. Antibiotics are an option but provide uncertain benefit. CBT remains a low-risk option. Studies support the use of IVIG, however more investigation is needed prior to widespread adoption of this treatment given its potential risks. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  3. Identifying lubricant options for compressor bearing designs

    NASA Astrophysics Data System (ADS)

    Karnaz, J.; Seeton, C.; Dixon, L.

    2017-08-01

    Today’s refrigeration and air conditioning market is not only driven by the environmental aspects of the refrigerants, but also by the energy efficiency and reliability of system operation. Numerous types of compressor designs are used in refrigeration and air conditioning applications which means that different bearings are used; and in some cases, multiple bearing types within a single compressor. Since only one lubricant is used, it is important to try to optimize the lubricant to meet the various demands and requirements for operation. This optimization entails investigating different types of lubricant chemistries, viscosities, and various formulation options. What makes evaluating these options more challenging is the refrigerant which changes the properties of the lubricant delivered to the bearing. Once the lubricant and refrigerant interaction are understood, through various test methods, then work can start on collaborating with compressor engineers on identifying the lubricant chemistry and formulation options. These interaction properties are important to the design engineer to make decisions on the adequacy of the lubricant before compressor tests are started. This paper will discuss the process to evaluate lubricants for various types of compressors and bearing design with focus on what’s needed for current refrigerant trends. In addition, the paper will show how the lubricant chemistry choice can be manipulated through understanding of the bearing design and knowledge of interaction with the refrigerant to maximize performance. Emphasis will be placed on evaluation of synthetic lubricants for both natural and synthetic low GWP refrigerants.

  4. Trends in Exiting Physics Master's. Focus On

    ERIC Educational Resources Information Center

    Mulvey, Patrick J.; Nicholson, Starr

    2014-01-01

    A physics master's degree provides the recipient with a variety of career options. Some master's recipients will continue their education at the graduate level in physics or another field, where others enter the workforce pursuing a wide range of employment opportunities. This "Focus On" provides an in-depth analysis of physics…

  5. Magnetic-field sensing coil embedded in ceramic for measuring ambient magnetic field

    DOEpatents

    Takahashi, Hironori

    2004-02-10

    A magnetic pick-up coil for measuring magnetic field with high specific sensitivity, optionally with an electrostatic shield (24), having coupling elements (22) with high winding packing ratio, oriented in multiple directions, and embedded in ceramic material for structural support and electrical insulation. Elements of the coil are constructed from green ceramic sheets (200) and metallic ink deposited on surfaces and in via holes of the ceramic sheets. The ceramic sheets and the metallic ink are co-fired to create a monolithic hard ceramic body (20) with metallized traces embedded in, and placed on exterior surfaces of, the hard ceramic body. The compact and rugged coil can be used in a variety of environments, including hostile conditions involving ultra-high vacuum, high temperatures, nuclear and optical radiation, chemical reactions, and physically demanding surroundings, occurring either individually or in combinations.

  6. Magnetic core shell nanoparticles trapping in a microdevice generating high magnetic gradient.

    PubMed

    Teste, Bruno; Malloggi, Florent; Gassner, Anne-Laure; Georgelin, Thomas; Siaugue, Jean-Michel; Varenne, Anne; Girault, Hubert; Descroix, Stéphanie

    2011-03-07

    Magnetic core shell nanoparticles (MCSNPs) 30 nm diameter with a magnetic weight of 10% are usually much too small to be trapped in microfluidic systems using classical external magnets. Here, a simple microchip for efficient MCSNPs trapping and release is presented. It comprises a bed of micrometric iron beads (6-8 μm diameter) packed in a microchannel against a physical restriction and presenting a low dead volume of 0.8 nL. These beads of high magnetic permeability are used to focus magnetic field lines from an external permanent magnet and generate local high magnetic gradients. The nanoparticles magnetic trap has been characterised both by numerical simulations and fluorescent MCSNPs imaging. Numerical simulations have been performed to map both the magnetic flux density and the magnetic force, and showed that MCSNPs are preferentially trapped at the iron bead magnetic poles where the magnetic force is increased by 3 orders of magnitude. The trapping efficiency was experimentally determined using fluorescent MCSNPs for different flow rates, different iron beads and permanent magnet positions. At a flow rate of 100 μL h(-1), the nanoparticles trapping/release can be achieved within 20 s with a preconcentration factor of 4000.

  7. Foil focusing of relativistic electron beams

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ekdahl, Jr., Carl August

    2017-10-26

    When an intense relativistic electron beams (IREB) passes through a grounded metal foil, the transverse electric field due to the beam space charge is locally shorted out, and the beam is focused by the magnetic field of its current. The effect can be treated as focusing by a thin lens with first order aberration. Expressions for the focal length and aberration coefficient of the equivalent thin lens are developed in this note. These are then applied to practical examples representative of IREB research at Los Alamos National Laboratory.

  8. 48 CFR 570.401 - Renewal options.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 4 2010-10-01 2010-10-01 false Renewal options. 570.401... Requirements 570.401 Renewal options. (a) Exercise of options. Before exercising an option to renew, follow the... survey. Before exercising an option to renew a lease, review current market information to ensure the...

  9. Development of TPF-1 plasma focus for education

    NASA Astrophysics Data System (ADS)

    Picha, R.; Promping, J.; Channuie, J.; Poolyarat, N.; Sangaroon, S.; Traikool, T.

    2017-09-01

    The plasma focus is a device that uses high voltage and electromagnetic force to induce plasma generation and acceleration, in order to cause nuclear reactions. Radiation of various types (X-ray, gamma ray, electrons, ions, neutrons) can be generated using this method during the pinch phase, thus making the plasma focus able to serve as a radiation source. Material testing, modification, and identification are among the current applications of the plasma focus. Other than being an alternative option to isotopic sources, the plasma focus, which requires multidisciplinary team of personnel to design, operate, and troubleshoot, can also serve as an excellent learning device for physics and engineering students in the fields including, but not limited to, plasma physics, nuclear physics, electronics engineering, and mechanical engineering. This work describes the parameters and current status of Thai Plasma Focus 1 (TPF-1) and the characteristics of the plasma being produced in the machine using a Rogowski coil.

  10. Opening Switch Research on a Plasma Focus VI.

    DTIC Science & Technology

    1988-02-26

    Sausage Instability in the Plasma Focus In this section the classical Kruskal- Schwarzschild 3 theory for the sausage mode is applied to the pinch phase...on 1) the shape of the pinch, 2) axial flow of plasma, and 3) self-generated magnetic fields are also presented. The Kruskal- Schwarzschild Theory The...classical mhd theory for the m=O mode in a plasma supported by a magnetic field against gravity; this is the well-known Kruskal- Schwarzschild

  11. Plasma separation from magnetic field lines in a magnetic nozzle

    NASA Technical Reports Server (NTRS)

    Kaufman, D. A.; Goodwin, D. G.; Sercel, J. C.

    1993-01-01

    This paper discusses conditions for separation of a plasma from the magnetic field of a magnetic nozzle. The analysis assumes a collisionless, quasineutral plasma, and therefore the results represent a lower bound on the amount of detachment possible for a given set of plasma conditions. We show that collisionless separation can occur because finite electron mass inhibits the flow of azimuthal currents in the nozzle. Separation conditions are governed by a parameter G which depends on plasma and nozzle conditions. Several methods of improving plasma detachment are presented, including moving the plasma generation zone downstream from the region of strongest magnetic field and using dual magnets to focus the plasma beam. Plasma detachment can be enhanced by manipulation of the nozzle configuration.

  12. Options for flight testing rocket-based combined-cycle (RBCC) engines

    NASA Technical Reports Server (NTRS)

    Olds, John

    1996-01-01

    While NASA's current next-generation launch vehicle research has largely focused on advanced all-rocket single-stage-to-orbit vehicles (i.e. the X-33 and it's RLV operational follow-on), some attention is being given to advanced propulsion concepts suitable for 'next-generation-and-a-half' vehicles. Rocket-based combined-cycle (RBCC) engines combining rocket and airbreathing elements are one candidate concept. Preliminary RBCC engine development was undertaken by the United States in the 1960's. However, additional ground and flight research is required to bring the engine to technological maturity. This paper presents two options for flight testing early versions of the RBCC ejector scramjet engine. The first option mounts a single RBCC engine module to the X-34 air-launched technology testbed for test flights up to about Mach 6.4. The second option links RBCC engine testing to the simultaneous development of a small-payload (220 lb.) two-stage-to-orbit operational vehicle in the Bantam payload class. This launcher/testbed concept has been dubbed the W vehicle. The W vehicle can also serve as an early ejector ramjet RBCC launcher (albeit at a lower payload). To complement current RBCC ground testing efforts, both flight test engines will use earth-storable propellants for their RBCC rocket primaries and hydrocarbon fuel for their airbreathing modes. Performance and vehicle sizing results are presented for both options.

  13. Magnetic resonance-guided focused ultrasound surgery (MRgFUS) of uterine fibroids in Singapore.

    PubMed

    Han, Nian-Lin R; Ong, Chiou Li

    2014-11-01

    Uterine fibroids are the most common type of gynaecologic benign tumours, occurring in 25% to 50% of women during their reproductive lives. About half of the affected women have clinically significant symptoms, including abnormal bleeding, menstrual pain, frequent urination, constipation and abdominal distension. Magnetic resonance-guided focused ultrasound surgery (MRgFUS) has been used to treat patients with benign lesions and a variety of malignancies. The objective of this study is to evaluate symptom relief before and after MR-guided ultrasound ablation of fibroids. A total of 37 patients with symptomatic uterine fibroids were treated in this study. MRgFUS treatment led to a significant, time-dependent decrease in not only Symptom Severity Scores (SSS), but also the mean fibroid volume. The average reductions in volume were 41.6% and 52.6% at 6 months and 12 months respectively (P <0.05). The mean SSS of the 37 patients was 41.7 ± 2.8 before treatment whereas the average SSS was 26.9 ± 3.6, 20.7 ± 3.4, 18.5 ± 3.6, 16.5 ± 7.1, 9.8 ± 3.6 at 3 months, 6 months, 1 year, 2 years, and 3 to 4 years respectively. The decrease in scores was significant at all time points up to 3 to 4 years (P <0.05 and P <0.001). MRgFUS is a safe and effective non-invasive treatment for patients with symptomatic fibroids.

  14. A magnetic field cloak for charged particle beams

    NASA Astrophysics Data System (ADS)

    Capobianco-Hogan, K. G.; Cervantes, R.; Deshpande, A.; Feege, N.; Krahulik, T.; LaBounty, J.; Sekelsky, R.; Adhyatman, A.; Arrowsmith-Kron, G.; Coe, B.; Dehmelt, K.; Hemmick, T. K.; Jeffas, S.; LaByer, T.; Mahmud, S.; Oliveira, A.; Quadri, A.; Sharma, K.; Tishelman-Charny, A.

    2018-01-01

    Shielding charged particle beams from transverse magnetic fields is a common challenge for particle accelerators and experiments. We demonstrate that a magnetic field cloak is a viable solution. It allows for the use of dipole magnets in the forward regions of experiments at an Electron Ion Collider (EIC) and other facilities without interfering with the incoming beams. The dipoles can improve the momentum measurements of charged final state particles at angles close to the beam line and therefore increase the physics reach of these experiments. In contrast to other magnetic shielding options (such as active coils), a cloak requires no external powering. We discuss the design parameters, fabrication, and limitations of a magnetic field cloak and demonstrate that cylinders made from 45 layers of YBCO high-temperature superconductor, combined with a ferromagnetic shell made from epoxy and stainless steel powder, shield more than 99% of a transverse magnetic field of up to 0.45 T (95% shielding at 0.5 T) at liquid nitrogen temperature. The ferromagnetic shell reduces field distortions caused by the superconductor alone by 90% at 0.45 T.

  15. Permanent Magnet Spiral Motor for Magnetic Gradient Energy Utilization: Axial Magnetic Field

    NASA Astrophysics Data System (ADS)

    Valone, Thomas F.

    2010-01-01

    The Spiral Magnetic Motor, which can accelerate a magnetized rotor through 90% of its cycle with only permanent magnets, was an energy milestone for the 20th century patents by Kure Tekkosho in the 1970's. However, the Japanese company used old ferrite magnets which are relatively weak and an electrically-powered coil to jump start every cycle, which defeated the primary benefit of the permanent magnet motor design. The principle of applying an inhomogeneous, anisotropic magnetic field gradient force Fz = μ cos φ dB/dz, with permanent magnets is well-known in physics, e.g., Stern-Gerlach experiment, which exploits the interaction of a magnetic moment with the aligned electron spins of magnetic domains. In this case, it is applied to dB/dθ in polar coordinates, where the force Fθ depends equally on the magnetic moment, the cosine of the angle between the magnetic moment and the field gradient. The radial magnetic field increases in strength (in the attractive mode) or decreases in strength (in the repulsive mode) as the rotor turns through one complete cycle. An electromagnetic pulsed switching has been historically used to help the rotor traverse the gap (detent) between the end of the magnetic stator arc and the beginning (Kure Tekko, 1980). However, alternative magnetic pulse and switching designs have been developed, as well as strategic eddy current creation. This work focuses on the switching mechanism, novel magnetic pulse methods and advantageous angular momentum improvements. For example, a collaborative effort has begun with Toshiyuki Ueno (University of Tokyo) who has invented an extremely low power, combination magnetostrictive-piezoelectric (MS-PZT) device for generating low frequency magnetic fields and consumes "zero power" for static magnetic field production (Ueno, 2004 and 2007a). Utilizing a pickup coil such as an ultra-miniature millihenry inductor with a piezoelectric actuator or simply Wiegand wire geometry, it is shown that the necessary

  16. Greenhouse Gas Mitigation Options Database and Tool - Data ...

    EPA Pesticide Factsheets

    Industry and electricity production facilities generate over 50 percent of greenhouse gas (GHG) emissions in the United States. There is a growing consensus among scientists that the primary cause of climate change is anthropogenic greenhouse gas (GHG) emissions. Reducing GHG emissions from these sources is a key part of the United States’ strategy to reduce the impacts of these global-warming emissions. As a result of the recent focus on GHG emissions, the U.S. Environmental Protection Agency (EPA) and state agencies are implementing policies and programs to quantify and regulate GHG emissions from key emitting sources in the United States. These policies and programs have generated a need for a reliable source of information regarding GHG mitigation options for both industry and regulators. In response to this need, EPA developed a comprehensive GHG mitigation options database (GMOD) that was compiled based on information from industry, government research agencies, and academia. The GMOD and Tool (GMODT) is a comprehensive data repository and analytical tool being developed by EPA to evaluate alternative GHG mitigation options for several high-emitting industry sectors, including electric power plants, cement plants, refineries, landfills and other industrial sources of GHGs. The data is collected from credible sources including peer-reviewed journals, reports, and others government and academia data sources which include performance, applicability, develop

  17. Efficient option valuation of single and double barrier options

    NASA Astrophysics Data System (ADS)

    Kabaivanov, Stanimir; Milev, Mariyan; Koleva-Petkova, Dessislava; Vladev, Veselin

    2017-12-01

    In this paper we present an implementation of pricing algorithm for single and double barrier options using Mellin transformation with Maximum Entropy Inversion and its suitability for real-world applications. A detailed analysis of the applied algorithm is accompanied by implementation in C++ that is then compared to existing solutions in terms of efficiency and computational power. We then compare the applied method with existing closed-form solutions and well known methods of pricing barrier options that are based on finite differences.

  18. Management Options for Biochemically Recurrent Prostate Cancer.

    PubMed

    Fakhrejahani, Farhad; Madan, Ravi A; Dahut, William L

    2017-05-01

    Prostate cancer is the most common solid tumor malignancy in men worldwide. Treatment with surgery and radiation can be curative in organ-confined disease. Unfortunately, about one third of men develop biochemically recurrent disease based only on rising prostate-specific antigen (PSA) in the absence of visible disease on conventional imaging. For these patients with biochemical recurrent prostate cancer, there is no uniform guideline for subsequent management. Based on available data, it seems prudent that biochemical recurrent prostate cancer should initially be evaluated for salvage radiation or prostatectomy, with curative intent. In selected cases, high-intensity focused ultrasound and cryotherapy may be considered in patients that meet very narrow criteria as defined by non-randomized trials. If salvage options are not practical or unsuccessful, androgen deprivation therapy (ADT) is a standard option for disease control. While some patients prefer ADT to manage the disease immediately, others defer treatment because of the associated toxicity. In the absence of definitive randomized data, patients may be followed using PSA doubling time as a trigger to initiate ADT. Based on retrospective data, a PSA doubling time of less than 3-6 months has been associated with near-term development of metastasis and thus could be used signal to initiate ADT. Once treatment is begun, patients and their providers can choose between an intermittent and continuous ADT strategy. The intermittent approach may limit side effects but in patients with metastatic disease studies could not exclude a 20% greater risk of death. In men with biochemical recurrence, large studies have shown that intermittent therapy is non-inferior to continuous therapy, thus making this a reasonable option. Since biochemically recurrent prostate cancer is defined by technological limitations of radiographic detection, as new imaging (i.e., PSMA) strategies are developed, it may alter how the disease is

  19. [Neuroprotective subthalamotomy in Parkinson's disease. The role of magnetic resonance-guided focused ultrasound in early surgery].

    PubMed

    Guridi, Jorge; Marigil, Miguel; Becerra, Victoria; Parras, Olga

    Subthalamic nucleus hyperactivity in Parkinson's disease may be a very early phenomenon. Its start is not well known, and it may occur during the pre-symptomatic disease stage. Glutamatergic hyperactivity may be neurotoxic over the substantia nigra compacta dopaminergic neurons. If this occurred, the excitatory neurotransmitter, glutamate, should affect the neurons that maintain a high turnover as a compensatory mechanism. Would a subthalamic nucleus lesion decrease this hyperactivity and thus be considered as a neuroprotective mechanism for dopaminergic neurons? The authors hypothesise about the possibility to perform surgery on a subthalamic nucleus lesion at a very early stage in order to avoid the neurotoxic glutamatergic effect over the dopaminergic neurons, and therefore be considered as a neuroprotective surgery able to alter the progress of the disease during early motor symptoms. In this regard, magnetic resonance-guided focused ultrasound techniques open a new window in the stereotactic armamentarium. Copyright © 2016 Sociedad Española de Neurocirugía. Publicado por Elsevier España, S.L.U. All rights reserved.

  20. Dopamine Modulates Option Generation for Behavior.

    PubMed

    Ang, Yuen-Siang; Manohar, Sanjay; Plant, Olivia; Kienast, Annika; Le Heron, Campbell; Muhammed, Kinan; Hu, Michele; Husain, Masud

    2018-05-21

    Animals make innumerable decisions every day, each of which involves evaluating potential options for action. But how are options generated? Although much is now known about decision making when a fixed set of potential options is provided, surprisingly little progress has been made on self-generated options. Some researchers have proposed that such abilities might be modulated by dopamine. Here, we used a new measure of option generation that is quantitative, objective, and culture fair to investigate how humans generate different behavioral options. Participants were asked to draw as many different paths (options) as they could between two points within a fixed time. Healthy individuals (n = 96) exhibited a trade-off between uniqueness (how individually different their options were) and fluency (number of options), generating either many similar or few unique options. To assess influence of dopamine, we first examined patients with Parkinson's disease (n = 35) ON and OFF their dopaminergic medication and compared them to elderly healthy controls (n = 34). Then we conducted a double-blind, placebo-controlled crossover study of the D2 agonist cabergoline in healthy older people (n = 29). Across both studies, dopamine increased fluency but diminished overall uniqueness of options generated, due to the effect of fluency trading off with uniqueness. Crucially, however, when this trade-off was corrected for, dopamine was found to increase uniqueness for any given fluency. Three carefully designed control studies showed that performance on our option-generation task was not related to executing movements, planning actions, or selecting between generated options. These findings show that dopamine plays an important role in modulating option generation. Copyright © 2018 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  1. Novel Therapeutic Strategies for Alcohol and Drug Addiction: Focus on GABA, Ion Channels and Transcranial Magnetic Stimulation

    PubMed Central

    Addolorato, Giovanni; Leggio, Lorenzo; Hopf, F Woodward; Diana, Marco; Bonci, Antonello

    2012-01-01

    Drug addiction represents a major social problem where addicts and alcoholics continue to seek and take drugs despite adverse social, personal, emotional, and legal consequences. A number of pharmacological compounds have been tested in human addicts with the goal of reducing the level or frequency of intake, but these pharmacotherapies have often been of only moderate efficacy or act in a sub-population of humans. Thus, there is a tremendous need for new therapeutic interventions to treat addiction. Here, we review recent interesting studies focusing on gamma-aminobutyric acid receptors, voltage-gated ion channels, and transcranial magnetic stimulation. Some of these treatments show considerable promise to reduce addictive behaviors, or the early clinical studies or pre-clinical rationale suggest that a promising avenue could be developed. Thus, it is likely that within a decade or so, we could have important new and effective treatments to achieve the goal of reducing the burden of human addiction and alcoholism. PMID:22030714

  2. 78 FR 7997 - Noncompensatory Partnership Options

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-02-05

    ...) accounting for noncompensatory options; (3) the characterization rule; (4) the convertible bond provision... option would necessitate adjustments to the capital accounting requirements of the regulations, as... the option. 2. Accounting for Noncompensatory Options A. Accounting for the Issuance of a...

  3. Following your heart or your head: focusing on emotions versus information differentially influences the decisions of younger and older adults.

    PubMed

    Mikels, Joseph A; Löckenhoff, Corinna E; Maglio, Sam J; Goldstein, Mary K; Garber, Alan; Carstensen, Laura L

    2010-03-01

    Research on aging has indicated that whereas deliberative cognitive processes decline with age, emotional processes are relatively spared. To examine the implications of these divergent trajectories in the context of health care choices, we investigated whether instructional manipulations emphasizing a focus on feelings or details would have differential effects on decision quality among younger and older adults. We presented 60 younger and 60 older adults with health care choices that required them to hold in mind and consider multiple pieces of information. Instructional manipulations in the emotion-focus condition asked participants to focus on their emotional reactions to the options, report their feelings about the options, and then make a choice. In the information-focus condition, participants were instructed to focus on the specific attributes, report the details about the options, and then make a choice. In a control condition, no directives were given. Manipulation checks indicated that the instructions were successful in eliciting different modes of processing. Decision quality data indicate that younger adults performed better in the information-focus than in the control condition whereas older adults performed better in the emotion-focus and control conditions than in the information-focus condition. Findings support and extend extant theorizing on aging and decision making as well as suggest that interventions to improve decision-making quality should take the age of the decision maker into account.

  4. Stability and trapping of magnetic resonance imaging contrast agents during high-intensity focused ultrasound ablation therapy.

    PubMed

    Hijnen, Nicole M; Elevelt, Aaldert; Grüll, Holger

    2013-07-01

    The purpose of this study was to investigate the use of Gd-DTPA shortly before magnetic resonance guided high-intensity focused ultrasound MR-HIFU thermal ablation therapy with respect to dissociation, trapping, and long-term deposition of gadolinium (Gd) in the body. Magnetic resonance-HIFU ablation treatment was conducted in vivo on both rat muscle and subcutaneous tumor (9L glioma) using a clinical 3T MR-HIFU system equipped with a small-animal coil setup. A human equivalent dose of gadopentetate dimeglumine (Gd-DTPA) (0.6 mmol/kg of body weight) was injected via a tail vein catheter just before ablation (≤5 minutes). Potential trapping of the contrast agent in the ablated area was visualized through the acquisition of R1 maps of the target location before and after therapy. The animals were sacrificed 2 hours or 14 days after the injection (n = 4 per group, a total of 40 animals). Subsequently, the Gd content in the tissue and carcass was determined using inductively coupled plasma techniques to investigate the biodistribution. Temporal trapping of Gd-DTPA in the coagulated tissue was observed on the R1 maps acquired within 2 hours after the ablation, an effect confirmed by the inductively coupled plasma analysis (3 times more Gd was found in the treated muscle volume than in the control muscle tissue). Two weeks after the therapy, the absolute amount of Gd present in the coagulated tissue was low compared with the amount present in the kidneys 14 days after the injection (ablated muscle, 0.009% ± 0.002% ID/g; kidney, 0.144% ± 0.165% ID/g). There was no significant increase in Gd content in the principal target organs for translocated Gdions (liver, spleen, and bone) or in the entire carcasses between the HIFU- and sham-treated animals. Finally, an in vivo relaxivity of 4.6 mmols was found in the HIFU-ablated volume, indicating intact Gd-DTPA. Magnetic resonance-HIFU treatment does not induce the dissociation of Gd-DTPA. In small-tissue volumes, no

  5. A viable dipole magnet concept with REBCO CORC® wires and further development needs for high-field magnet applications

    NASA Astrophysics Data System (ADS)

    Wang, Xiaorong; Caspi, Shlomo; Dietderich, Daniel R.; Ghiorso, William B.; Gourlay, Stephen A.; Higley, Hugh C.; Lin, Andy; Prestemon, Soren O.; van der Laan, Danko; Weiss, Jeremy D.

    2018-04-01

    REBCO coated conductors maintain a high engineering current density above 16 T at 4.2 K. That fact will significantly impact markets of various magnet applications including high-field magnets for high-energy physics and fusion reactors. One of the main challenges for the high-field accelerator magnet is the use of multi-tape REBCO cables with high engineering current density in magnet development. Several approaches developing high-field accelerator magnets using REBCO cables are demonstrated. In this paper, we introduce an alternative concept based on the canted cos θ (CCT) magnet design using conductor on round core (CORC®) wires that are wound from multiple REBCO tapes with a Cu core. We report the development and test of double-layer three-turn CCT dipole magnets using CORC® wires at 77 and 4.2 K. The scalability of the CCT design allowed us to effectively develop and demonstrate important magnet technology features such as coil design, winding, joints and testing with minimum conductor lengths. The test results showed that the CCT dipole magnet using CORC® wires was a viable option in developing a REBCO accelerator magnet. One of the critical development needs is to increase the engineering current density of the 3.7 mm diameter CORC® wire to 540 A mm-2 at 21 T, 4.2 K and to reduce the bending radius to 15 mm. This would enable a compact REBCO dipole insert magnet to generate a 5 T field in a background field of 16 T at 4.2 K.

  6. A DG approach to the numerical solution of the Stein-Stein stochastic volatility option pricing model

    NASA Astrophysics Data System (ADS)

    Hozman, J.; Tichý, T.

    2017-12-01

    Stochastic volatility models enable to capture the real world features of the options better than the classical Black-Scholes treatment. Here we focus on pricing of European-style options under the Stein-Stein stochastic volatility model when the option value depends on the time, on the price of the underlying asset and on the volatility as a function of a mean reverting Orstein-Uhlenbeck process. A standard mathematical approach to this model leads to the non-stationary second-order degenerate partial differential equation of two spatial variables completed by the system of boundary and terminal conditions. In order to improve the numerical valuation process for a such pricing equation, we propose a numerical technique based on the discontinuous Galerkin method and the Crank-Nicolson scheme. Finally, reference numerical experiments on real market data illustrate comprehensive empirical findings on options with stochastic volatility.

  7. 48 CFR 17.107 - Options.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 1 2010-10-01 2010-10-01 false Options. 17.107 Section 17... CONTRACT TYPES SPECIAL CONTRACTING METHODS Multiyear Contracting 17.107 Options. Benefits may accrue by including options in a multiyear contract. In that event, contracting officers must follow the requirements...

  8. 48 CFR 2917.207 - Exercising options.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 7 2010-10-01 2010-10-01 false Exercising options. 2917... AND CONTRACT TYPES SPECIAL CONTRACTING METHODS Options 2917.207 Exercising options. The contracting officer must use a standardized determination and finding before exercising an option in accordance with...

  9. Alopecia Areata: Review of Epidemiology, Clinical Features, Pathogenesis, and New Treatment Options

    PubMed Central

    Darwin, Evan; Hirt, Penelope A; Fertig, Raymond; Doliner, Brett; Delcanto, Gina; Jimenez, Joaquin J

    2018-01-01

    Alopecia areata (AA) is a complex autoimmune condition that causes nonscarring hair loss. It typically presents with sharply demarcated round patches of hair loss and may present at any age. In this article, we review the epidemiology, clinical features, pathogenesis, and new treatment options of AA, with a focus on the immunologic mechanism underlying the treatment. While traditional treatment options such as corticosteroids are moderately effective, a better understanding of the disease pathogenesis may lead to the development of new treatments that are more directed and effective against AA. Sources were gathered from PubMed, Embase, and the Cochrane database using the keywords: alopecia, alopecia areata, hair loss, trichoscopy, treatments, pathogenesis, and epidemiology. PMID:29769777

  10. Note: A sample holder design for sensitive magnetic measurements at high temperatures in a magnetic properties measurement system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Arauzo, A.; Guerrero, E.; Urtizberea, A.

    2012-06-15

    A sample holder design for high temperature measurements in a commercial MPMS SQUID magnetometer from Quantum Design is presented. It fulfills the requirements for the simultaneous use of the oven and reciprocating sample option (RSO) options, thus allowing sensitive magnetic measurements up to 800 K. Alternating current susceptibility can also be measured, since the holder does not induce any phase shift relative to the ac driven field. It is easily fabricated by twisting Constantan Copyright-Sign wires into a braid nesting the sample inside. This design ensures that the sample be placed tightly into a tough holder with its orientation fixed,more » and prevents any sample displacement during the fast movements of the RSO transport, up to high temperatures.« less

  11. 38 CFR 6.10 - Options.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 1 2010-07-01 2010-07-01 false Options. 6.10 Section 6.10 Pensions, Bonuses, and Veterans' Relief DEPARTMENT OF VETERANS AFFAIRS UNITED STATES GOVERNMENT LIFE INSURANCE Optional Settlement § 6.10 Options. Insurance will be payable in one sum only when...

  12. Dynamic inversion enables external magnets to concentrate ferromagnetic rods to a central target.

    PubMed

    Nacev, A; Weinberg, I N; Stepanov, P Y; Kupfer, S; Mair, L O; Urdaneta, M G; Shimoji, M; Fricke, S T; Shapiro, B

    2015-01-14

    The ability to use magnets external to the body to focus therapy to deep tissue targets has remained an elusive goal in magnetic drug targeting. Researchers have hitherto been able to manipulate magnetic nanotherapeutics in vivo with nearby magnets but have remained unable to focus these therapies to targets deep within the body using magnets external to the body. One of the factors that has made focusing of therapy to central targets between magnets challenging is Samuel Earnshaw's theorem as applied to Maxwell's equations. These mathematical formulations imply that external static magnets cannot create a stable potential energy well between them. We posited that fast magnetic pulses could act on ferromagnetic rods before they could realign with the magnetic field. Mathematically, this is equivalent to reversing the sign of the potential energy term in Earnshaw's theorem, thus enabling a quasi-static stable trap between magnets. With in vitro experiments, we demonstrated that quick, shaped magnetic pulses can be successfully used to create inward pointing magnetic forces that, on average, enable external magnets to concentrate ferromagnetic rods to a central location.

  13. 48 CFR 317.107 - Options.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 4 2010-10-01 2010-10-01 false Options. 317.107 Section... CONTRACT TYPES SPECIAL CONTRACTING METHODS Multi-year Contracting 317.107 Options. When used as part of a multi-year contract, options shall not be used to extend the performance of the original requirement for...

  14. 38 CFR 8.25 - Options.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 1 2010-07-01 2010-07-01 false Options. 8.25 Section 8.25 Pensions, Bonuses, and Veterans' Relief DEPARTMENT OF VETERANS AFFAIRS NATIONAL SERVICE LIFE INSURANCE Optional Settlements § 8.25 Options. Insurance will be paid in a lump sum only when selected by...

  15. Bounds for Asian basket options

    NASA Astrophysics Data System (ADS)

    Deelstra, Griselda; Diallo, Ibrahima; Vanmaele, Michèle

    2008-09-01

    In this paper we propose pricing bounds for European-style discrete arithmetic Asian basket options in a Black and Scholes framework. We start from methods used for basket options and Asian options. First, we use the general approach for deriving upper and lower bounds for stop-loss premia of sums of non-independent random variables as in Kaas et al. [Upper and lower bounds for sums of random variables, Insurance Math. Econom. 27 (2000) 151-168] or Dhaene et al. [The concept of comonotonicity in actuarial science and finance: theory, Insurance Math. Econom. 31(1) (2002) 3-33]. We generalize the methods in Deelstra et al. [Pricing of arithmetic basket options by conditioning, Insurance Math. Econom. 34 (2004) 55-57] and Vanmaele et al. [Bounds for the price of discrete sampled arithmetic Asian options, J. Comput. Appl. Math. 185(1) (2006) 51-90]. Afterwards we show how to derive an analytical closed-form expression for a lower bound in the non-comonotonic case. Finally, we derive upper bounds for Asian basket options by applying techniques as in Thompson [Fast narrow bounds on the value of Asian options, Working Paper, University of Cambridge, 1999] and Lord [Partially exact and bounded approximations for arithmetic Asian options, J. Comput. Finance 10 (2) (2006) 1-52]. Numerical results are included and on the basis of our numerical tests, we explain which method we recommend depending on moneyness and time-to-maturity.

  16. OPTION(5) versus OPTION(12) instruments to appreciate the extent to which healthcare providers involve patients in decision-making.

    PubMed

    Stubenrouch, Fabienne E; Pieterse, Arwen H; Falkenberg, Rijan; Santema, T Katrien B; Stiggelbout, Anne M; van der Weijden, Trudy; Aarts, J Annemijn W M; Ubbink, Dirk T

    2016-06-01

    The 12-item "observing patient involvement" (OPTION(12))-instrument is commonly used to assess the extent to which healthcare providers involve patients in health-related decision-making. The five-item version (OPTION(5)) claims to be a more efficient measure. In this study we compared the Dutch versions of the OPTION-instruments in terms of inter-rater agreement and correlation in outpatient doctor-patient consultations in various settings, to learn if we can safely switch to the shorter OPTION(5)-instrument. Two raters coded 60 audiotaped vascular surgery and oncology patient consultations using OPTION(12) and OPTION(5). Unweighted Cohen's kappa was used to compute inter-rater agreement on item-level. The association between the total scores of the two OPTION-instruments was investigated using Pearson's correlation coefficient (r) and a Bland & Altman plot. After fine-tuning the OPTION-manuals, inter-rater agreement for OPTION(12) and OPTION(5) was good to excellent (kappa range 0.69-0.85 and 0.63-0.72, respectively). Mean total scores were 23.7 (OPTION(12); SD=7.8) and 39.3 (OPTION(5); SD=12.7). Correlation between the total scores was high (r=0.71; p=0.01). OPTION(5) scored systematically higher with a wider range than OPTION(12). Both OPTION-instruments had a good inter-rater agreement and correlated well. OPTION(5) seems to differentiate better between various levels of patient involvement. The OPTION(5)-instrument is recommended for clinical application. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  17. 24 CFR 206.19 - Payment options.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 24 Housing and Urban Development 2 2010-04-01 2010-04-01 false Payment options. 206.19 Section 206... CONVERSION MORTGAGE INSURANCE Eligibility; Endorsement Eligible Mortgages § 206.19 Payment options. (a) Term payment option. Under the term payment option, equal monthly payments are made by the mortgagee to the...

  18. Magnetic Resonance–Guided High-Intensity Focused Ultrasound (MRgHIFU) Treatment of Symptomatic Uterine Fibroids: An Evidence-Based Analysis

    PubMed Central

    Pron, G

    2015-01-01

    Background Magnetic resonance–guided high-intensity focused ultrasound (MRgHIFU) is a noninvasive uterine-preserving treatment alternative to hysterectomy for women with symptomatic uterine leiomyomas (fibroids). Uterine fibroids commonly occur, have a broad impact on women's health and lifestyle, continue to be the main indication for hysterectomy, and represent a costly public health burden. Objectives The objectives of the analysis were to evaluate patients’ eligibility for MRgHIFU treatment of symptomatic uterine fibroids and the technical success, safety, effectiveness, and durability of this treatment. The review also compared the safety and effectiveness of MRgHIFU with other minimally invasive uterine-preserving treatments and surgeries for uterine fibroids. Methods A literature search was performed on March 27, 2014, using Ovid MEDLINE, Ovid MEDLINE In-Process and Other Non-Indexed Citations, Ovid EMBASE, EBSCO Cumulative Index to Nursing & Allied Health Literature (CINAHL), and EBM Reviews, for studies published from January 1, 2000, to March 27, 2014. Results The evidence review identified 2 systematic reviews, 2 RCTs, 45 cohort study reports, and 19 case reports involving HIFU treatment of symptomatic uterine fibroids. Eligibility for MRgHIFU treatment was variable, ranging from 14% to 74%. In clinical cohort studies involving 1,594 patients, 26 major complications (1.6%) were reported. MRgHIFU resulted in statistically and clinically significant reductions in fibroid-related symptoms in studies conducted in 10 countries, although few involved follow-up longer than 1 year. Retreatment rates following MRgHIFU were higher in early clinical studies involving regulated restrictions in the extent of fibroid ablation than in later reports involving near-complete ablation. Emergent interventions, however, were rare. Although a desire for fertility was an exclusion criteria for treatment, spontaneous term pregnancies did occur following HIFU. There were no

  19. Effect of polarization and focusing on laser pulse driven auto-resonant particle acceleration

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sagar, Vikram; Sengupta, Sudip; Kaw, Predhiman

    2014-04-15

    The effect of laser polarization and focusing is theoretically studied on the final energy gain of a particle in the Auto-resonant acceleration scheme using a finite duration laser pulse with Gaussian shaped temporal envelope. The exact expressions for dynamical variables viz. position, momentum, and energy are obtained by analytically solving the relativistic equation of motion describing particle dynamics in the combined field of an elliptically polarized finite duration pulse and homogeneous static axial magnetic field. From the solutions, it is shown that for a given set of laser parameters viz. intensity and pulse length along with static magnetic field, themore » energy gain by a positively charged particle is maximum for a right circularly polarized laser pulse. Further, a new scheme is proposed for particle acceleration by subjecting it to the combined field of a focused finite duration laser pulse and static axial magnetic field. In this scheme, the particle is initially accelerated by the focused laser field, which drives the non-resonant particle to second stage of acceleration by cyclotron Auto-resonance. The new scheme is found to be efficient over two individual schemes, i.e., auto-resonant acceleration and direct acceleration by focused laser field, as significant particle acceleration can be achieved at one order lesser values of static axial magnetic field and laser intensity.« less

  20. 24 CFR 35.120 - Options.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 24 Housing and Urban Development 1 2010-04-01 2010-04-01 false Options. 35.120 Section 35.120... and Definitions for All Programs. § 35.120 Options. (a) Standard treatments. Where interim controls are required by this part, the designated party has the option to presume that lead-based paint or...

  1. Options for the Development of Noninvasive Glucose Monitoring

    PubMed Central

    Thomas, Andreas; Heinemann, Lutz; Ramírez, Araceli; Zehe, Alfred

    2015-01-01

    Nowadays nanotechnology has many applications in products used in various areas of daily life; however, this technology has also an option in modern medicine and pharmacy. Therefore, this technology is also an attractive option for the field of diagnosis and treatment of diabetes. Many people with diabetes measure their blood glucose levels regularly to determine the insulin dose. Ideally glucose values would be measured noninvasively (NI). However, none of all the NI approaches studied in the past decades enabled reliable NI measurements under all daily life conditions. Particularly an unfavorable signal-to-noise ratio turned out to be problematic. Based on the known physical possibilities for NI glucose monitoring the focus of this review is on nanotechnology approaches. Functional prototypes exist for some of these that showed promising results under defined laboratory conditions, indicating a good sensitivity and selectivity for glucose. On the second hand is to optimize the technological process of manufacturing. In view of the rapid progress in micro- and nanoelectronics hopefully NI glucose monitoring systems can be developed in the near future. PMID:26581879

  2. Magnetic Assisted Colloidal Pattern Formation

    NASA Astrophysics Data System (ADS)

    Yang, Ye

    Pattern formation is a mysterious phenomenon occurring at all scales in nature. The beauty of the resulting structures and myriad of resulting properties occurring in naturally forming patterns have attracted great interest from scientists and engineers. One of the most convenient experimental models for studying pattern formation are colloidal particle suspensions, which can be used both to explore condensed matter phenomena and as a powerful fabrication technique for forming advanced materials. In my thesis, I have focused on the study of colloidal patterns, which can be conveniently tracked in an optical microscope yet can also be thermally equilibrated on experimentally relevant time scales, allowing for ground states and transitions between them to be studied with optical tracking algorithms. In particular, I have focused on systems that spontaneously organize due to particle-surface and particle-particle interactions, paying close attention to systems that can be dynamically adjusted with an externally applied magnetic or acoustic field. In the early stages of my doctoral studies, I developed a magnetic field manipulation technique to quantify the adhesion force between particles and surfaces. This manipulation technique is based on the magnetic dipolar interactions between colloidal particles and their "image dipoles" that appear within planar substrate. Since the particles interact with their own images, this system enables massively parallel surface force measurements (>100 measurements) in a single experiment, and allows statistical properties of particle-surface adhesion energies to be extracted as a function of loading rate. With this approach, I was able to probe sub-picoNewton surface interactions between colloidal particles and several substrates at the lowest force loading rates ever achieved. In the later stages of my doctoral studies, I focused on studying patterns formed from particle-particle interaction, which serve as an experimental model of

  3. 17 CFR 32.3 - Trade options.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 17 Commodity and Securities Exchanges 1 2014-04-01 2014-04-01 false Trade options. 32.3 Section 32... OPTION TRANSACTIONS § 32.3 Trade options. (a) Subject to paragraphs (b), (c), and (d) of this section... period preceding the date on which the trade option is entered into, (iv) In connection with any non...

  4. 17 CFR 32.3 - Trade options.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 17 Commodity and Securities Exchanges 1 2013-04-01 2013-04-01 false Trade options. 32.3 Section 32... OPTION TRANSACTIONS § 32.3 Trade options. (a) Subject to paragraphs (b), (c), and (d) of this section... period preceding the date on which the trade option is entered into, (iv) In connection with any non...

  5. Five focus strategies to organize health care delivery.

    PubMed

    Peltokorpi, Antti; Linna, Miika; Malmström, Tomi; Torkki, Paulus; Lillrank, Paul Martin

    2016-01-01

    The focused factory is one of the concepts that decision-makers have adopted for improving health care delivery. However, disorganized definitions of focus have led to findings that cannot be utilized systematically. The purpose of this paper is to discuss strategic options to focus health care operations. First the literature on focus in health care is reviewed revealing conceptual challenges. Second, a definition of focus in terms of demand and requisite variety is defined, and the mechanisms of focus are explicated. A classification of five focus strategies that follow the original idea to reduce variety in products and markets is presented. Finally, the paper examines managerial possibilities linked to the focus strategies. The paper proposes a framework of five customer-oriented focus strategies which aim at reducing variety in different characteristics of care pathways: population; urgency and severity; illnesses and symptoms; care practices and processes; and care outcomes. Empirical research is needed to evaluate the costs and benefits of the five strategies and about system-level effects of focused units on competition and coordination. Focus is an enabling condition that needs to be exploited using specific demand and supply management practices. It is essential to understand how focus mechanisms differ between strategies, and to select focus that fits with organization's strategy and key performance indicators. Compared to previous more resource-oriented approaches, this study provides theoretically solid and practically relevant customer-oriented framework for focusing in health care.

  6. 26 CFR 1.544-4 - Options.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 26 Internal Revenue 7 2010-04-01 2010-04-01 true Options. 1.544-4 Section 1.544-4 Internal Revenue... (CONTINUED) Personal Holding Companies § 1.544-4 Options. The shares of stock which may be acquired by reason of an option shall be considered to be constructively owned by the individual having the option to...

  7. Carbon-Containing Waste of Coal Enterprises in Magnetic Sorbents Technology

    NASA Astrophysics Data System (ADS)

    Kvashevaya, Ekaterina; Ushakova, Elena; Ushakov, Andrey

    2017-11-01

    The article shows the issues state of coal-mining enterprises carbonaceous wastes utilization, including by obtaining oil-sorbent. The characteristics of the feedstock are presented; experiment methods of obtaining a binder based on the livestock enterprises waste, of forming binder with filler (sawdust, coal waste); of pyrogenetic processing to obtain a sorbent are described. Possible options for the introduction of magnetite (a magnetic component) in the composition of the oil sorbent are considered: on the surface, in the volume of the granule and the magnetite core. In the course of the work it was found that the optimum content of coal dust in the sorbent granules is 75% by weight, and the most effective way of obtaining the magnetic sorbent is to apply the carbon material directly to the "core" of magnetite. However, in this case, the problem of finding an effective binder for magnetite arises. The option of applying magnetite on the surface of a carbon sorbent is not effective. Thus, at present, we use a mixture of coal waste, which binds to the uniform distribution of magnetite in the volume. The developed magnetic sorbents can be used in various weather conditions, including strong winds and icing of water bodies, as well as for small and medium currents.

  8. On production and asymmetric focusing of flat electron beams using rectangular capillary discharge plasmas

    DOE PAGES

    Bagdasarov, G. A.; Bobrova, N. A.; Boldarev, A. S.; ...

    2017-12-27

    A method for the asymmetric focusing of electron bunches, based on the active plasma lensing technique is proposed. Our method takes advantage of the strong inhomogeneous magnetic field generated inside the capillary discharge plasma to focus the ultrarelativistic electrons. The plasma and magnetic field parameters inside the capillary discharge are described theoretically and modeled with dissipative magnetohydrodynamic computer simulations enabling analysis of the capillaries of rectangle cross-sections. We could use large aspect ratio rectangular capillaries to transport electron beams with high emittance asymmetries, as well as assist in forming spatially flat electron bunches for final focusing before the interaction point.

  9. On production and asymmetric focusing of flat electron beams using rectangular capillary discharge plasmas

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bagdasarov, G. A.; Bobrova, N. A.; Boldarev, A. S.

    A method for the asymmetric focusing of electron bunches, based on the active plasma lensing technique is proposed. Our method takes advantage of the strong inhomogeneous magnetic field generated inside the capillary discharge plasma to focus the ultrarelativistic electrons. The plasma and magnetic field parameters inside the capillary discharge are described theoretically and modeled with dissipative magnetohydrodynamic computer simulations enabling analysis of the capillaries of rectangle cross-sections. We could use large aspect ratio rectangular capillaries to transport electron beams with high emittance asymmetries, as well as assist in forming spatially flat electron bunches for final focusing before the interaction point.

  10. On production and asymmetric focusing of flat electron beams using rectangular capillary discharge plasmas

    NASA Astrophysics Data System (ADS)

    Bagdasarov, G. A.; Bobrova, N. A.; Boldarev, A. S.; Olkhovskaya, O. G.; Sasorov, P. V.; Gasilov, V. A.; Barber, S. K.; Bulanov, S. S.; Gonsalves, A. J.; Schroeder, C. B.; van Tilborg, J.; Esarey, E.; Leemans, W. P.; Levato, T.; Margarone, D.; Korn, G.; Kando, M.; Bulanov, S. V.

    2017-12-01

    A method for the asymmetric focusing of electron bunches, based on the active plasma lensing technique, is proposed. This method takes advantage of the strong inhomogeneous magnetic field generated inside the capillary discharge plasma to focus on the ultrarelativistic electrons. The plasma and magnetic field parameters inside the capillary discharge are described theoretically and modeled with dissipative magnetohydrodynamic computer simulations enabling analysis of the capillaries of rectangle cross-sections. Large aspect ratio rectangular capillaries might be used to transport electron beams with high emittance asymmetries, as well as assist in forming spatially flat electron bunches for final focusing before the interaction point.

  11. A Case of 2-Year-Old Child with Entero-Enteric Fistula Following Ingestion of 25 Magnets.

    PubMed

    Pogorelić, Zenon; Borić, Matija; Markić, Joško; Jukić, Miro; Grandić, Leo

    Magnet ingestion usually does not cause serious complications, but in case of multiple magnet ingestion or ingestion of magnet with other metal it could cause intestinal obstruction, fistula formation or even perforation. We report case of intestinal obstruction and fistula formation following ingestion of 25 magnets in a 2-year-old girl. Intraoperatively omega shaped intestinal loop with fistula caused by two magnetic balls was found. Intestine trapped with magnetic balls was edematous and inflamed. Resection of intestinal segment was performed, followed by entero-enteric anastomosis. A total of 25 magnets were removed from resected intestine. Single magnet ingestion is treated as non-magnetic foreign body. Multiple magnet ingestion should be closely monitored and surgical approach could be the best option to prevent or to cure its complications.

  12. A magnetic field cloak for charged particle beams

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Capobianco-Hogan, K. G.; Cervantes, R.; Deshpande, A.

    Shielding charged particle beams from transverse magnetic fields is a common challenge for particle accelerators and experiments. In this study, we demonstrate that a magnetic field cloak is a viable solution. It allows for the use of dipole magnets in the forward regions of experiments at an Electron Ion Collider (EIC) and other facilities without interfering with the incoming beams. The dipoles can improve the momentum measurements of charged final state particles at angles close to the beam line and therefore increase the physics reach of these experiments. In contrast to other magnetic shielding options (such as active coils), amore » cloak requires no external powering. We discuss the design parameters, fabrication, and limitations of a magnetic field cloak and demonstrate that cylinders made from 45 layers of YBCO high-temperature superconductor, combined with a ferromagnetic shell made from epoxy and stainless steel powder, shield more than 99% of a transverse magnetic field of up to 0.45 T (95% shielding at 0.5 T) at liquid nitrogen temperature. Lastly, the ferromagnetic shell reduces field distortions caused by the superconductor alone by 90% at 0.45 T.« less

  13. A magnetic field cloak for charged particle beams

    DOE PAGES

    Capobianco-Hogan, K. G.; Cervantes, R.; Deshpande, A.; ...

    2017-10-02

    Shielding charged particle beams from transverse magnetic fields is a common challenge for particle accelerators and experiments. In this study, we demonstrate that a magnetic field cloak is a viable solution. It allows for the use of dipole magnets in the forward regions of experiments at an Electron Ion Collider (EIC) and other facilities without interfering with the incoming beams. The dipoles can improve the momentum measurements of charged final state particles at angles close to the beam line and therefore increase the physics reach of these experiments. In contrast to other magnetic shielding options (such as active coils), amore » cloak requires no external powering. We discuss the design parameters, fabrication, and limitations of a magnetic field cloak and demonstrate that cylinders made from 45 layers of YBCO high-temperature superconductor, combined with a ferromagnetic shell made from epoxy and stainless steel powder, shield more than 99% of a transverse magnetic field of up to 0.45 T (95% shielding at 0.5 T) at liquid nitrogen temperature. Lastly, the ferromagnetic shell reduces field distortions caused by the superconductor alone by 90% at 0.45 T.« less

  14. Magnets, children and the bowel: a dangerous attraction?

    PubMed

    George, Anil Thomas; Motiwale, Sandeep

    2012-10-14

    Reports of magnet ingestion are increasing rapidly globally. However, multiple magnet ingestion, the subsequent potential complications and the importance of the early identification and proper management remain both under-recognized and underestimated. Published literature on such cases could possibly represent only the tip of an iceberg with press reports, web blogs and government documents highlighting further occurrence of many more such incidents. The increasing number of complications worldwide being reported secondary to magnet ingestion point not only to an acute lack of awareness about this condition among the medical profession but also among parents and carers who will be in most cases the first to pick up on magnet ingestion. There still seems to be no consensus on the management of magnet ingestion with several algorithms being proposed for management. Prevention of this condition remains a much better option than cure. Proper education and improved awareness among parents and carers and frontline medical staff is key in addressing this rapidly emerging problem. The goal of managing such cases of suspected magnet ingestion should be aimed at reducing delays between ingestion time, diagnosis time and intervention time.

  15. Magnets, children and the bowel: A dangerous attraction?

    PubMed Central

    George, Anil Thomas; Motiwale, Sandeep

    2012-01-01

    Reports of magnet ingestion are increasing rapidly globally. However, multiple magnet ingestion, the subsequent potential complications and the importance of the early identification and proper management remain both under-recognized and underestimated. Published literature on such cases could possibly represent only the tip of an iceberg with press reports, web blogs and government documents highlighting further occurrence of many more such incidents. The increasing number of complications worldwide being reported secondary to magnet ingestion point not only to an acute lack of awareness about this condition among the medical profession but also among parents and carers who will be in most cases the first to pick up on magnet ingestion. There still seems to be no consensus on the management of magnet ingestion with several algorithms being proposed for management. Prevention of this condition remains a much better option than cure. Proper education and improved awareness among parents and carers and frontline medical staff is key in addressing this rapidly emerging problem. The goal of managing such cases of suspected magnet ingestion should be aimed at reducing delays between ingestion time, diagnosis time and intervention time. PMID:23082048

  16. 45 CFR 1306.34 - Combination program option.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 45 Public Welfare 4 2010-10-01 2010-10-01 false Combination program option. 1306.34 Section 1306... START PROGRAM HEAD START STAFFING REQUIREMENTS AND PROGRAM OPTIONS Head Start Program Options § 1306.34 Combination program option. (a) Combination program option requirements: (1) Grantees implementing a...

  17. Family options for parents with mental illnesses: a developmental, mixed methods pilot study.

    PubMed

    Nicholson, Joanne; Albert, Karen; Gershenson, Bernice; Williams, Valerie; Biebel, Kathleen

    2009-01-01

    The objective of this paper is to provide a description of Family Options, a rehabilitation intervention for parents with serious mental illnesses and their children focusing on recovery and resilience, and to report the findings from a pilot study at 6-months post-enrollment for participating mothers. A developmental design, and mixed quantitative and qualitative methods facilitate an in-depth understanding of Family Options and its impact on parents early in the implementation process. Participating families faced significant challenges, including long-term mental health conditions in adults, and emotional and behavioral difficulties in children. Data from mothers (n = 22) demonstrate significant improvements in well-being, functioning, and supports and resources at 6 months post-enrollment in Family Options. Mothers report help from Family Options staff consistent with the intervention as conceptualized, and high levels of satisfaction with the intervention as delivered. Innovative study design and analytic strategies are required to build the evidence base and promote rapid dissemination of effective interventions. Findings from this study will assist purveyors in refining the intervention, and will lay the groundwork for further replication and testing to build the evidence base for parents with serious mental illnesses and their families.

  18. Spin-orbit torque induced magnetic vortex polarity reversal utilizing spin-Hall effect

    NASA Astrophysics Data System (ADS)

    Li, Cheng; Cai, Li; Liu, Baojun; Yang, Xiaokuo; Cui, Huanqing; Wang, Sen; Wei, Bo

    2018-05-01

    We propose an effective magnetic vortex polarity reversal scheme that makes use of spin-orbit torque introduced by spin-Hall effect in heavy-metal/ferromagnet multilayers structure, which can result in subnanosecond polarity reversal without endangering the structural stability. Micromagnetic simulations are performed to investigate the spin-Hall effect driven dynamics evolution of magnetic vortex. The mechanism of magnetic vortex polarity reversal is uncovered by a quantitative analysis of exchange energy density, magnetostatic energy density, and their total energy density. The simulation results indicate that the magnetic vortex polarity is reversed through the nucleation-annihilation process of topological vortex-antivortex pair. This scheme is an attractive option for ultra-fast magnetic vortex polarity reversal, which can be used as the guidelines for the choice of polarity reversal scheme in vortex-based random access memory.

  19. 24 CFR 982.625 - Homeownership option: General.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 24 Housing and Urban Development 4 2010-04-01 2010-04-01 false Homeownership option: General. 982... Types Homeownership Option § 982.625 Homeownership option: General. (a) The homeownership option is used... family assisted under the homeownership option may be a newly admitted or existing participant in the...

  20. 48 CFR 517.207 - Exercise of options.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 4 2010-10-01 2010-10-01 false Exercise of options. 517... METHODS AND CONTRACT TYPES SPECIAL CONTRACTING METHODS Options 517.207 Exercise of options. Before exercising an option, you must: (a) Synopsize it unless you meet of the following conditions: (1) The option...

  1. Future Fuels

    DTIC Science & Technology

    2006-04-01

    relevant to TWV is focused on permanent magnet motors , often wheel mounted. Wound rotor motors provide substantially different design and control...options than permanent magnet motors , at the expense of additional cooling requirements. Their benefits include higher peak torque and less sensitivity

  2. Reducing the Deficit: Spending and Revenue Options

    DTIC Science & Technology

    2011-03-01

    the Conservation Reserve Program 25AgricultureOption 6 Reduce the Premium Subsidy in the Crop Insurance Program 26Option 7 Reduce by 20 Percentage...Graduate Students 31Option 11 Change the Interest Rate Structure for Student Loans 32HealthOption 12 Add a “Public Plan” to the Health Insurance Exchanges...Health Episodes Covered by Medicare 48Option 21 Reduce Medicare Costs by Changing the Cost-Sharing Structures for Medicare and Medigap Insurance 49Option

  3. Declining average daily census. Part 1: Implications and options.

    PubMed

    Weil, T P

    1985-12-01

    A national trend toward declining average daily (inpatient) census (ADC) started in late 1982 even before the Medicare prospective payment system began. The decrease in total days will continue despite an increasing number of aged persons in the U.S. population. This decline could have been predicted from trends during 1978 to 1983, such as increasing available beds but decreasing occupancy, 100 percent increases in hospital expenses, and declining lengths of stay. Assuming that health care costs will remain as a relatively fixed part of the gross national product and no major medical advances will occur in the next five years, certain implications and options exist for facilities experiencing a declining ADC. This article discusses several considerations: Attempts to improve market share; Reduction of full-time equivalent employees; Impact of greater acuity of illness among remaining inpatients; Implications of increasing the number of physicians on medical staffs; Option of a closed medical staff by clinical specialty; Unbundling with not-for-profit and profit-making corporations; Review of mergers, consolidations, and multihospital systems to decide when this option is most appropriate; Sale of a not-for-profit hospital to an investor-owned chain, with implications facing Catholic hospitals choosing this option; Impact and difficulty of developing meaningful alternative health care systems with the hospital's medical staff; Special problems of teaching hospitals; The social issue of the hospital shifting from the community's health center to a cost center; Increased turnover of hospital CEOs; With these in mind, institutions can then focus on solutions that can sometimes be used in tandem to resolve this problem's impact. The second part of this article will discuss some of them.

  4. Valuing options in shot noise market

    NASA Astrophysics Data System (ADS)

    Laskin, Nick

    2018-07-01

    A new exactly solvable option pricing model has been introduced and elaborated. It is assumed that a stock price follows a Geometric shot noise process. An arbitrage-free integro-differential option pricing equation has been obtained and solved. The new Greeks have been analytically calculated. It has been shown that in diffusion approximation the developed option pricing model incorporates the well-known Black-Scholes equation and its solution. The stochastic dynamic origin of the Black-Scholes volatility has been uncovered. To model the observed market stock price patterns consisting of high frequency small magnitude and low frequency large magnitude jumps, the superposition of two Geometric shot noises has been implemented. A new generalized option pricing equation has been obtained and its exact solution was found. Merton's jump-diffusion formula for option price was recovered in diffusion approximation. Despite the non-Gaussian nature of probability distributions involved, the new option pricing model has the same degree of analytical tractability as the Black-Scholes model and the Merton jump-diffusion model. This attractive feature allows one to derive exact formulas to value options and option related instruments in the market with jump-like price patterns.

  5. SEATSAT programs option analysis

    NASA Technical Reports Server (NTRS)

    Luckl, L.

    1976-01-01

    A preliminary analysis of the costs of SEASAT follow-on options is presented. All the options assume the existence of SEASAT-A as currently defined in the SEASAT Economic Assessment. It is assumed that each option will continue through the year 2000 and approach operational system status in the 1983-1986 period, depending upon the sensor package selected. The launch vehicle assumed through 1983 is the Atlas Agena. After 1983, it is assumed SEASAT-A will switch to the use of the Space Shuttle. All cost estimates are 1976 dollars for fiscal year cost accounting, with no inflation rate included.

  6. Association between physicians' beliefs and the option of comfort care for critically ill patients.

    PubMed

    Schenker, Yael; Tiver, Greer A; Hong, Seo Yeon; White, Douglas B

    2012-10-01

    For critically ill patients at high risk of death, reasonable treatment options include attempts at life prolongation and treatment focused on comfort. Little is known about whether and how physicians present the option of comfort care to surrogates. This study assessed how comfort care is presented to surrogates and whether physicians' beliefs are associated with whether comfort care is presented as an option. Mixed-methods study of 72 audio-recorded family conferences about treatment decisions in five ICUs at two hospitals in San Francisco, California. One hundred sixty-nine family members and 54 physicians participated. Patients were at high risk of death or severe functional impairment. Transcripts of audio-recorded conferences were coded to identify whether physicians offered comfort care as an alternative to life-sustaining treatment and to characterize the stated risks and benefits. Physicians completed a questionnaire indicating the strength of their belief that life support should be foregone. The inpatient mortality rate was 72 %. Using a broad definition of comfort-oriented treatment, this option was presented in 56 % (95 % CI, 44-67 %) of conferences. In clustered multivariate models, the only independent predictor of offering comfort care as an option was the strength of the physician's belief that life support should be foregone [OR 1.38 (1.14-1.66), p = 0.01]. Clinicians did not explicitly inform surrogates about the option of comfort-oriented treatment in roughly half of clinician-family meetings. Physicians who more strongly believe that the appropriate goal of care is life prolongation are less likely to inform surrogates about the option of comfort care.

  7. Nano-Magnets and Additive Manufacturing for Electric Motors

    NASA Technical Reports Server (NTRS)

    Misra, Ajay K.

    2014-01-01

    High power density is required for application of electric motors in hybrid electric propulsion. Potential path to achieve high power density in electric motors include advanced materials, lightweight thermal management, lightweight structural concepts, high power density power electronics, and advanced manufacturing. This presentation will focus on two key technologies for achieving high power density, advanced magnets and additive manufacturing. The maximum energy product in current magnets is reaching their theoretical limits as a result of material and process improvements. Future improvements in the maximum energy product for magnets can be achieved through development of nanocomposite magnets combining the hard magnetic phase and soft magnetic phase at the nanoscale level. The presentation will provide an overview of the current state of development for nanocomposite magnets and the future path for doubling the maximum energy product. The other part of the presentation will focus on the role of additive manufacturing in fabrication of high power density electric motors. The presentation will highlight the potential opportunities for applying additive manufacturing to fabricate electric motors.

  8. Study of Agricultural Product Options Pricing

    NASA Astrophysics Data System (ADS)

    HONG, Qiu

    2017-09-01

    China is a large agricultural country, and the healthy development of agriculture is related to the stability of the whole society. The agricultural production and management of agricultural products are confronted with many risks, especially the market risks. Option contract is the object of option market transaction, so it is very important to study the option contract of agricultural products. Option trading separates the risk and profit, so that the trader can avoid the risk while retaining the opportunity to obtain income. The option has the characteristics of low transaction cost, simple and efficient, so it is suitable for small and medium investors.

  9. Focus on Opportunities as a Mediator of the Relationships between Age, Job Complexity, and Work Performance

    ERIC Educational Resources Information Center

    Zacher, Hannes; Heusner, Sandra; Schmitz, Michael; Zwierzanska, Monika M.; Frese, Michael

    2010-01-01

    "Focus on opportunities" is a cognitive-motivational facet of occupational future time perspective that describes how many new goals, options, and possibilities individuals expect to have in their personal work-related futures. This study examined focus on opportunities as a mediator of the relationships between age and work performance and…

  10. Radiation damage and waste management options for the SOMBRERO final focus system and neutron dumps

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Latkowski, J F; Meier, W R; Reyes, S

    1999-08-09

    Previous studies of the safety and environmental aspects of the SOMBRERO inertial fusion energy (IFE) power plant design did not completely address the issues associated with the final focus system. While past work calculated neutron fluences for a grazing incidence metal mirror (GIMM) and a final focus mirror, scattering off of the final optical component was not included, and thus, fluences in the final focus mirror were significantly underestimated. In addition, past work did not consider neutron-induced gamma-rays. Finally, power plant lifetime waste volumes may have been underestimated as neutron activation of the neutron dumps and building structure were notmore » addressed. In the present work, a modified version of the SOMBRERO target building is presented where a significantly larger open solid-angle fraction (5%) is used to enhance beam smoothing of a diode-pumped solid-state laser (DPSSL). The GIMMs are replaced with transmissive fused silica wedges and have been included in three -dimensional neutron and photon transport calculations. This work shows that a power plant with a large open solid-angle fraction, needed for beam smoothing with a DPSSL, is acceptable from tritium breeding, and neutron activation points-of-view.« less

  11. On the Asymmetric Focusing of Low-Emittance Electron Bunches via Active Lensing by Using Capillary Discharges

    NASA Astrophysics Data System (ADS)

    Bulanov, Stepan; Bagdasarov, Gennadiy; Bobrova, Nadezhda; Boldarev, Alexey; Olkhovskaya, Olga; Sasorov, Pavel; Gasilov, Vladimir; Barber, Samuel; Gonsalves, Anthony; Schroeder, Carl; van Tilborg, Jeroen; Esarey, Eric; Leemans, Wim; Levato, Tadzio; Margarone, Daniele; Korn, Georg; Kando, Masaki; Bulanov, Sergei

    2017-10-01

    A novel method for asymmetric focusing of electron beams is proposed. The scheme is based on the active lensing technique, which takes advantage of the strong inhomogeneous magnetic field generated inside the capillary discharge plasma to focus the ultrarelativistic electrons. The plasma and magnetic field parameters inside a capillary discharge are described theoretically and modeled with dissipative MHD simulations to enable analysis of capillaries of oblong rectangle cross-sections implying that large aspect ratio rectangular capillaries can be used to form flat electron bunches. The effect of the capillary cross-section on the electron beam focusing properties were studied using the analytical methods and simulation- derived magnetic field map showing the range of the capillary discharge parameters required for producing the high quality flat electron beams.

  12. Magnetic quench antenna for MQXF quadrupoles

    DOE PAGES

    Marchevsky, Maxim; Sabbi, GianLuca; Prestemon, Soren; ...

    2016-12-21

    High-field MQXF-series quadrupoles are presently under development by LARP and CERN for the upcoming LHC luminosity upgrade. Quench training and protection studies on MQXF prototypes require a capability to accurately localize quenches and measure their propagation velocity in the magnet coils. The voltage tap technique commonly used for such purposes is not a convenient option for the 4.2-m-long MQXF-A prototype, nor can it be implemented in the production model. We have developed and tested a modular inductive magnetic antenna for quench localization. The base element of our quench antenna is a round-shaped printed circuit board containing two orthogonal pairs ofmore » flat coils integrated with low-noise preamplifiers. The elements are aligned axially and spaced equidistantly in 8-element sections using a supporting rod structure. The sections are installed in the warm bore of the magnet, and can be stacked together to adapt for the magnet length. We discuss the design, operational characteristics and preliminary qualification of the antenna. Lastly, axial quench localization capability with an accuracy of better than 2 cm has been validated during training test campaign of the MQXF-S1 quadrupole.« less

  13. Magnetic quench antenna for MQXF quadrupoles

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Marchevsky, Maxim; Sabbi, GianLuca; Prestemon, Soren

    High-field MQXF-series quadrupoles are presently under development by LARP and CERN for the upcoming LHC luminosity upgrade. Quench training and protection studies on MQXF prototypes require a capability to accurately localize quenches and measure their propagation velocity in the magnet coils. The voltage tap technique commonly used for such purposes is not a convenient option for the 4.2-m-long MQXF-A prototype, nor can it be implemented in the production model. We have developed and tested a modular inductive magnetic antenna for quench localization. The base element of our quench antenna is a round-shaped printed circuit board containing two orthogonal pairs ofmore » flat coils integrated with low-noise preamplifiers. The elements are aligned axially and spaced equidistantly in 8-element sections using a supporting rod structure. The sections are installed in the warm bore of the magnet, and can be stacked together to adapt for the magnet length. We discuss the design, operational characteristics and preliminary qualification of the antenna. Lastly, axial quench localization capability with an accuracy of better than 2 cm has been validated during training test campaign of the MQXF-S1 quadrupole.« less

  14. Analytical estimation of ultrasound properties, thermal diffusivity, and perfusion using magnetic resonance-guided focused ultrasound temperature data

    PubMed Central

    Dillon, C R; Borasi, G; Payne, A

    2016-01-01

    For thermal modeling to play a significant role in treatment planning, monitoring, and control of magnetic resonance-guided focused ultrasound (MRgFUS) thermal therapies, accurate knowledge of ultrasound and thermal properties is essential. This study develops a new analytical solution for the temperature change observed in MRgFUS which can be used with experimental MR temperature data to provide estimates of the ultrasound initial heating rate, Gaussian beam variance, tissue thermal diffusivity, and Pennes perfusion parameter. Simulations demonstrate that this technique provides accurate and robust property estimates that are independent of the beam size, thermal diffusivity, and perfusion levels in the presence of realistic MR noise. The technique is also demonstrated in vivo using MRgFUS heating data in rabbit back muscle. Errors in property estimates are kept less than 5% by applying a third order Taylor series approximation of the perfusion term and ensuring the ratio of the fitting time (the duration of experimental data utilized for optimization) to the perfusion time constant remains less than one. PMID:26741344

  15. Magnetic Nanoparticles: From Design and Synthesis to Real World Applications

    PubMed Central

    Kudr, Jiri; Heger, Zbynek; Cernak, Mirko; Adam, Vojtech; Zitka, Ondrej

    2017-01-01

    The increasing number of scientific publications focusing on magnetic materials indicates growing interest in the broader scientific community. Substantial progress was made in the synthesis of magnetic materials of desired size, morphology, chemical composition, and surface chemistry. Physical and chemical stability of magnetic materials is acquired by the coating. Moreover, surface layers of polymers, silica, biomolecules, etc. can be designed to obtain affinity to target molecules. The combination of the ability to respond to the external magnetic field and the rich possibilities of coatings makes magnetic materials universal tool for magnetic separations of small molecules, biomolecules and cells. In the biomedical field, magnetic particles and magnetic composites are utilized as the drug carriers, as contrast agents for magnetic resonance imaging (MRI), and in magnetic hyperthermia. However, the multifunctional magnetic particles enabling the diagnosis and therapy at the same time are emerging. The presented review article summarizes the findings regarding the design and synthesis of magnetic materials focused on biomedical applications. We highlight the utilization of magnetic materials in separation/preconcentration of various molecules and cells, and their use in diagnosis and therapy. PMID:28850089

  16. Energy storage options for space power

    NASA Astrophysics Data System (ADS)

    Hoffman, H. W.; Martin, J. F.; Olszewski, M.

    Including energy storage in a space power supply enhances the feasibility of using thermal power cycles (Rankine or Brayton) and providing high-power pulses. Superconducting magnets, capacitors, electrochemical batteries, thermal phase-change materials (PCM), and flywheels are assessed; the results obtained suggest that flywheels and phase-change devices hold the most promise. Latent heat storage using inorganic salts and metallic eutectics offers thermal energy storage densities of 1500 kJ/kg to 2000 kJ/kg at temperatures to 1675 K. Innovative techniques allow these media to operate in direct contact with the heat engine working fluid. Enhancing thermal conductivity and/or modifying PCM crystallization habit provide other options. Flywheels of low-strain graphite and Kevlar fibers have achieved mechanical energy storage densities of 300 kJ/kg. With high-strain graphite fibers, storage densities appropriate to space power needs (about 500 kJ/kg) seem feasible. Coupling advanced flywheels with emerging high power density homopolar generators and compulsators could result in electric pulse-power storage modules of significantly higher energy density.

  17. 17 CFR 32.13 - Exemption from prohibition of commodity option transactions for trade options on certain...

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... trade option merchant's internal controls with respect to market risk, credit risk, and other risks... disclosure statement: This brief statement does not disclose all of the risks and other significant aspects... from sources other than the person selling you this option about the use and risks of option contracts...

  18. 17 CFR 32.13 - Exemption from prohibition of commodity option transactions for trade options on certain...

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 17 Commodity and Securities Exchanges 1 2011-04-01 2011-04-01 false Exemption from prohibition of commodity option transactions for trade options on certain agricultural commodities. 32.13 Section 32.13 Commodity and Securities Exchanges COMMODITY FUTURES TRADING COMMISSION REGULATION OF COMMODITY OPTION TRANSACTIONS § 32.13 Exemption from...

  19. Micro-focused Brillouin light scattering study of the magnetization dynamics driven by Spin Hall effect in a transversely magnetized NiFe nanowire

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Madami, M., E-mail: marco.madami@fisica.unipg.it; Carlotti, G.; Gubbiotti, G.

    2015-05-07

    We employed micro-focused Brillouin light scattering to study the amplification of the thermal spin wave eigenmodes by means of a pure spin current, generated by the spin-Hall effect, in a transversely magnetized Pt(4 nm)/NiFe(4 nm)/SiO{sub 2}(5 nm) layered nanowire with lateral dimensions 500 × 2750 nm{sup 2}. The frequency and the cross section of both the center (fundamental) and the edge spin wave modes have been measured as a function of the intensity of the injected dc electric current. The frequency of both modes exhibits a clear redshift while their cross section is greatly enhanced on increasing the intensity of the injected dc. A threshold-like behaviormore » is observed for a value of the injected dc of 2.8 mA. Interestingly, an additional mode, localized in the central part of the nanowire, appears at higher frequency on increasing the intensity of the injected dc above the threshold value. Micromagnetic simulations were used to quantitatively reproduce the experimental results and to investigate the complex non-linear dynamics induced by the spin-Hall effect, including the modification of the spatial profile of the spin wave modes and the appearance of the extra mode above the threshold.« less

  20. Using tevatron magnets for HE-LHC or new ring in LHC tunnel

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Piekarz, Henryk; /Fermilab

    Two injector accelerator options for HE-LHC of p{sup +} - p{sup +} collisions at 33 TeV cms energy are briefly outlined. One option is based on the Super-SPS (S-SPS) accelerator in the SPS tunnel, and the other one is based on the LER (Low-Energy-Ring) accelerator in the LHC tunnel. Expectations of performance of the main arc accelerator magnets considered for the construction of the S-SPS and of the LER accelerators are used to tentatively devise some selected properties of these accelerators as potential injectors to HE-LHC.

  1. Attracted by a magnet: Exploration behaviour of rodents in the presence of magnetic objects.

    PubMed

    Malewski, Sandra; Malkemper, E Pascal; Sedláček, František; Šumbera, Radim; Caspar, Kai R; Burda, Hynek; Begall, Sabine

    2018-06-01

    Magnetosensitivity is widespread among animals with rodents being the most intensively studied mammalian group. The available behavioural assays for magnetoreception are time-consuming, which impedes screens for treatment effects that could characterize the enigmatic magnetoreceptors. Here, we present a fast and simple approach to test if an animal responds to magnetic stimuli: the magnetic object assay (MOA). The MOA focuses on investigating an animal's spontaneous exploration behaviour in the presence of a bar magnet compared to a demagnetised control. We present consistently longer exploration of the magnet in three different rodent species: Ansell's mole-rat (Fukomys anselli), C57BL/6J laboratory mouse, and naked mole-rat (Heterocephalus glaber). For the naked mole-rat this is the first report that this species reacts on magnetic stimuli. We conclude that the MOA holds the potential to screen if an animal responds to magnetic stimuli, indicating the possession of a magnetic sense. Copyright © 2018 Elsevier B.V. All rights reserved.

  2. Shaping magnetic fields to direct therapy to ears and eyes.

    PubMed

    Shapiro, B; Kulkarni, S; Nacev, A; Sarwar, A; Preciado, D; Depireux, D A

    2014-07-11

    Magnetic fields have the potential to noninvasively direct and focus therapy to disease targets. External magnets can apply forces on drug-coated magnetic nanoparticles, or on living cells that contain particles, and can be used to manipulate them in vivo. Significant progress has been made in developing and testing safe and therapeutic magnetic constructs that can be manipulated by magnetic fields. However, we do not yet have the magnet systems that can then direct those constructs to the right places, in vivo, over human patient distances. We do not yet know where to put the external magnets, how to shape them, or when to turn them on and off to direct particles or magnetized cells-in blood, through tissue, and across barriers-to disease locations. In this article, we consider ear and eye disease targets. Ear and eye targets are too deep and complex to be targeted by a single external magnet, but they are shallow enough that a combination of magnets may be able to direct therapy to them. We focus on how magnetic fields should be shaped (in space and time) to direct magnetic constructs to ear and eye targets.

  3. Therapeutic options for management of endometrial hyperplasia

    PubMed Central

    2016-01-01

    Endometrial hyperplasia (EH) comprises a spectrum of changes in the endometrium ranging from a slightly disordered pattern that exaggerates the alterations seen in the late proliferative phase of the menstrual cycle to irregular, hyperchromatic lesions that are similar to endometrioid adenocarcinoma. Generally, EH is caused by continuous exposure of estrogen unopposed by progesterone, polycystic ovary syndrome, tamoxifen, or hormone replacement therapy. Since it can progress, or often occur coincidentally with endometrial carcinoma, EH is of clinical importance, and the reversion of hyperplasia to normal endometrium represents the key conservative treatment for prevention of the development of adenocarcinoma. Presently, cyclic progestin or hysterectomy constitutes the major treatment option for EH without or with atypia, respectively. However, clinical trials of hormonal therapies and definitive standard treatments remain to be established for the management of EH. Moreover, therapeutic options for EH patients who wish to preserve fertility are challenging and require nonsurgical management. Therefore, future studies should focus on evaluation of new treatment strategies and novel compounds that could simultaneously target pathways involved in the pathogenesis of estradiol-induced EH. Novel therapeutic agents precisely targeting the inhibition of estrogen receptor, growth factor receptors, and signal transduction pathways are likely to constitute an optimal approach for treatment of EH. PMID:26463434

  4. Therapeutic options for management of endometrial hyperplasia.

    PubMed

    Chandra, Vishal; Kim, Jong Joo; Benbrook, Doris Mangiaracina; Dwivedi, Anila; Rai, Rajani

    2016-01-01

    Endometrial hyperplasia (EH) comprises a spectrum of changes in the endometrium ranging from a slightly disordered pattern that exaggerates the alterations seen in the late proliferative phase of the menstrual cycle to irregular, hyperchromatic lesions that are similar to endometrioid adenocarcinoma. Generally, EH is caused by continuous exposure of estrogen unopposed by progesterone, polycystic ovary syndrome, tamoxifen, or hormone replacement therapy. Since it can progress, or often occur coincidentally with endometrial carcinoma, EH is of clinical importance, and the reversion of hyperplasia to normal endometrium represents the key conservative treatment for prevention of the development of adenocarcinoma. Presently, cyclic progestin or hysterectomy constitutes the major treatment option for EH without or with atypia, respectively. However, clinical trials of hormonal therapies and definitive standard treatments remain to be established for the management of EH. Moreover, therapeutic options for EH patients who wish to preserve fertility are challenging and require nonsurgical management. Therefore, future studies should focus on evaluation of new treatment strategies and novel compounds that could simultaneously target pathways involved in the pathogenesis of estradiol-induced EH. Novel therapeutic agents precisely targeting the inhibition of estrogen receptor, growth factor receptors, and signal transduction pathways are likely to constitute an optimal approach for treatment of EH.

  5. Thickness dependence of the magnetic anisotropy and dynamic magnetic response of ferromagnetic NiFe films

    NASA Astrophysics Data System (ADS)

    Silva, E. F.; Corrêa, M. A.; Della Pace, R. D.; Plá Cid, C. C.; Kern, P. R.; Carara, M.; Chesman, C.; Alves Santos, O.; Rodríguez-Suárez, R. L.; Azevedo, A.; Rezende, S. M.; Bohn, F.

    2017-05-01

    We investigate the thickness dependence of the magnetic anisotropy and dynamic magnetic response of ferromagnetic NiFe films. We go beyond quasi-static measurements and focus on the dynamic magnetic response by considering three complementary techniques: the ferromagnetic resonance, magnetoimpedance and magnetic permeability measurements. We verify remarkable modifications in the magnetic anisotropy, i.e. the well-known behavior of in-plane uniaxial magnetic anisotropy systems gives place to a complex magnetic behavior as the thickness increases, and splits the films in two groups according to the magnetic properties. We identify magnetoimpedance and magnetic permeability curves with multiple resonance peaks, as well as the evolution of the ferromagnetic resonance absorption spectra, as fingerprints of strong changes of the magnetic properties associated to the vanishing of the in-plane magnetic anisotropy and to the emergence of non-homogeneous magnetization configuration, local anisotropies and out-of-plane anisotropy contribution arisen as a consequence of the non-uniformities of the stress stored in the film as the thickness is increased and/or to the columnar growth of the film. We interpret the experimental results in terms of the structural and morphological properties, quasi-static magnetic behavior, magnetic domain structure and different mechanisms governing the magnetization dynamics at distinct frequency ranges.

  6. Saw-tooth refractive lens for high energy x-ray focusing

    NASA Astrophysics Data System (ADS)

    Antimonov, Mikhail A.; Khounsary, Ali M.

    2014-09-01

    Saw-tooth refractive lens (SRL) provides a comparatively attractive option for X-ray focusing. An SRL assembly consists of two parts, each with an array of triangular structures (prisms), set tilted symmetrically with respect to the incoming beam. Its main advantage is a simple, continuous tunability in energy and focal length. SRLs can be used for both long and short focal length focusing. Long focal distance focusing of an SRL can accurately be predicted using simple analytical relations. However, the focus size at short focal distances focusing may deviate appreciably from the expected demagnified source size when: (1) the length of the SRL is comparable with the focusing distance, (2) the incident beam is not monochromatic, and (3) and the distance between adjacent prism tips, the tip step, is large . The first factor was considered in a previous work while the other two are addressed is this paper. This preliminary work is aimed at a better understanding of the SRL lenses for focusing an undulator beamline at the Advanced Photon Source (APS).

  7. 48 CFR 3017.202 - Use of options.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 7 2010-10-01 2010-10-01 false Use of options. 3017.202... ACQUISITION REGULATION (HSAR) CONTRACT METHODS AND CONTRACT TYPES SPECIAL CONTRACTING METHODS Options. 3017.202 Use of options. (a) Contracting officers shall not use unpriced options. ...

  8. Magnetocaloric effect: permanent magnet array for generation of high magnetic fields

    NASA Astrophysics Data System (ADS)

    Lee, Seong-Jae; Kenkel, John; Jiles, David

    2002-03-01

    The magnetocaloric effect (MCE), the heating or cooling of magnetic materials in a magnetic field, is unusually large in the Gd_5(Si_xGe_1-x)4 alloy system. Normally the maximum in the MCE occurs at the Curie temperature (Tc) because the spin entropy change is a maximum. By suitable selection of the composition of this alloy system the Curie temperature can be changed over the range 25 K for x = 0 to 340 K for x =1, and the composition range around x = 0.5 exhibits the largest magnetocaloric effect. In order to increase the amount of heat exchanged the change in applied magnetic field should be as large as possible, and in this research values above 1.5 Tesla are suggested. We have studied a permanent magnet array based on NdFeB, which with a remanent magnetization of only 1.2 Tesla can still generate a magnetic flux density, or magnetic induction B of 2-3 Tesla. In order to generate the high magnetic induction in the absence of a power supply, a modified hollow cylindrical permanent magnet array (HCPMA) has been designed to produce the required strength of magnetic field. Soft magnetic materials including permalloy (NiFe) were used for focusing the magnetic field in the central region. The magnitude of the magnetic flux density at the center was about 2 Tesla. The magnitude and homogeneity of the magnetic field for this design are comparable with the conventional C-shaped yoke and HCPMA. This can be easily adapted for a low power rotary system in which the magnetocaloric material can be exposed alternately to high and low magnetic fields so that it can accept and reject heat from its surroundings.

  9. Novel treatment options for portal hypertension

    PubMed Central

    Laleman, Wim

    2017-01-01

    Abstract Portal hypertension is most frequently associated with cirrhosis and is a major driver for associated complications, such as variceal bleeding, ascites or hepatic encephalopathy. As such, clinically significant portal hypertension forms the prelude to decompensation and impacts significantly on the prognosis of patients with liver cirrhosis. At present, non-selective β-blockers, vasopressin analogues and somatostatin analogues are the mainstay of treatment but these strategies are far from satisfactory and only target splanchnic hyperemia. In contrast, safe and reliable strategies to reduce the increased intrahepatic resistance in cirrhotic patients still represent a pending issue. In recent years, several preclinical and clinical trials have focused on this latter component and other therapeutic avenues. In this review, we highlight novel data in this context and address potentially interesting therapeutic options for the future. PMID:28533907

  10. Numerical investigation of the dynamics of Janus magnetic particles in a rotating magnetic field

    NASA Astrophysics Data System (ADS)

    Kim, Hui Eun; Kim, Kyoungbeom; Ma, Tae Yeong; Kang, Tae Gon

    2017-02-01

    We investigated the rotational dynamics of Janus magnetic particles suspended in a viscous liquid, in the presence of an externally applied rotating magnetic field. A previously developed two-dimensional direct simulation method, based on the finite element method and a fictitious domain method, is employed to solve the magnetic particulate flow. As for the magnetic problem, the two Maxwell equations are converted to a differential equation using the magnetic potential. The magnetic forces acting on the particles are treated by a Maxwell stress tensor formulation, enabling us to consider the magnetic interactions among the particles without any approximation. The dynamics of a single particle in the rotating field is studied to elucidate the effect of the Mason number and the magnetic susceptibility on the particle motions. Then, we extended our interest to a two-particle problem, focusing on the effect of the initial configuration of the particles on the particle motions. In three-particle interaction problems, the particle dynamics and the fluid flow induced by the particle motions are significantly affected by the particle configuration and the orientation of each particle.

  11. FOREWORD: Focus on Advanced Ceramics Focus on Advanced Ceramics

    NASA Astrophysics Data System (ADS)

    Ohashi, Naoki

    2011-06-01

    Much research has been devoted recently to developing technologies for renewable energy and improving the efficiency of the processes and devices used in industry and everyday life. Efficient solutions have been found using novel materials such as platinum and palladium-based catalysts for car exhaust systems, samarium-cobalt and neodymium-iron-boron permanent magnets for electrical motors, and so on. However, their realization has resulted in an increasing demand for rare elements and in their deficit, the development of new materials based on more abundant elements and new functionalities of traditional materials. Moreover, increasing environmental and health concerns demand substitution of toxic or hazardous substances with nature-friendly alternatives. In this context, this focus issue on advanced ceramics aims to review current trends in ceramics science and technology. It is related to the International Conference on Science and Technology of Advanced Ceramics (STAC) held annually to discuss the emerging issues in the field of ceramics. An important direction of ceramic science is the collaboration between experimental and theoretical sciences. Recent developments in density functional theory and computer technology have enabled the prediction of physical and chemical properties of ceramics, thereby assisting the design of new materials. Therefore, this focus issue includes articles devoted to theory and advanced characterization techniques. As mentioned above, the potential shortage of rare elements is becoming critical to the industry and has resulted in a Japanese government initiative called the 'Ubiquitous Element Strategy'. This focus issue also includes articles related to this strategy and to the associated topics of energy conversion, such as phosphors for high-efficiency lighting and photocatalysts for solar-energy harvesting. We hope that this focus issue will provide a timely overview of current trends and problems in ceramics science and

  12. Imaging of dynamic magnetic fields with spin-polarized neutron beams

    DOE PAGES

    Tremsin, A. S.; Kardjilov, N.; Strobl, M.; ...

    2015-04-22

    Precession of neutron spin in a magnetic field can be used for mapping of a magnetic field distribution, as demonstrated previously for static magnetic fields at neutron beamline facilities. The fringing in the observed neutron images depends on both the magnetic field strength and the neutron energy. In this paper we demonstrate the feasibility of imaging periodic dynamic magnetic fields using a spin-polarized cold neutron beam. Our position-sensitive neutron counting detector, providing with high precision both the arrival time and position for each detected neutron, enables simultaneous imaging of multiple phases of a periodic dynamic process with microsecond timing resolution.more » The magnetic fields produced by 5- and 15-loop solenoid coils of 1 cm diameter, are imaged in our experiments with ~100 μm resolution for both dc and 3 kHz ac currents. Our measurements agree well with theoretical predictions of fringe patterns formed by neutron spin precession. We also discuss the wavelength dependence and magnetic field quantification options using a pulsed neutron beamline. Furthermore, the ability to remotely map dynamic magnetic fields combined with the unique capability of neutrons to penetrate various materials (e.g., metals), enables studies of fast periodically changing magnetic processes, such as formation of magnetic domains within metals due to the presence of ac magnetic fields.« less

  13. Imaging of dynamic magnetic fields with spin-polarized neutron beams

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tremsin, A. S.; Kardjilov, N.; Strobl, M.

    Precession of neutron spin in a magnetic field can be used for mapping of a magnetic field distribution, as demonstrated previously for static magnetic fields at neutron beamline facilities. The fringing in the observed neutron images depends on both the magnetic field strength and the neutron energy. In this paper we demonstrate the feasibility of imaging periodic dynamic magnetic fields using a spin-polarized cold neutron beam. Our position-sensitive neutron counting detector, providing with high precision both the arrival time and position for each detected neutron, enables simultaneous imaging of multiple phases of a periodic dynamic process with microsecond timing resolution.more » The magnetic fields produced by 5- and 15-loop solenoid coils of 1 cm diameter, are imaged in our experiments with ~100 μm resolution for both dc and 3 kHz ac currents. Our measurements agree well with theoretical predictions of fringe patterns formed by neutron spin precession. We also discuss the wavelength dependence and magnetic field quantification options using a pulsed neutron beamline. Furthermore, the ability to remotely map dynamic magnetic fields combined with the unique capability of neutrons to penetrate various materials (e.g., metals), enables studies of fast periodically changing magnetic processes, such as formation of magnetic domains within metals due to the presence of ac magnetic fields.« less

  14. 48 CFR 1517.207 - Exercise of options.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 6 2010-10-01 2010-10-01 true Exercise of options. 1517... CONTRACTING METHODS AND CONTRACT TYPES SPECIAL CONTRACTING METHODS Options 1517.207 Exercise of options. (a) Unless otherwise approved by the Chief of the Contracting Office, contracts for services employing option...

  15. 24 CFR 982.636 - Homeownership option: Portability.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 24 Housing and Urban Development 4 2010-04-01 2010-04-01 false Homeownership option: Portability... Types Homeownership Option § 982.636 Homeownership option: Portability. (a) General. A family may... described in §§ 982.353 and 982.355 apply to the homeownership option and the administrative...

  16. 48 CFR 317.207 - Exercise of options.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 4 2010-10-01 2010-10-01 false Exercise of options. 317... METHODS AND CONTRACT TYPES SPECIAL CONTRACTING METHODS Options 317.207 Exercise of options. (h) Before exercising an option for a subsequent performance period/additional quantity under a multiple-year contract...

  17. Fluid flow analysis and vertical gradient freeze crystal growth in a travelling magnetic field

    NASA Astrophysics Data System (ADS)

    Lantzsch, R.; Grants, I.; Galindo, V.; Patzold, O.; Gerbeth, G.; Stelter, M.; Croll, A.

    2006-12-01

    In bulk crystal growth of semiconductors the concept of remote flow control by means of alternating magnetic fields has attracted considerable interest (see, e.g., te{1,2,3,4,5,6}). In this way the melt flow can be tailored for growth under optimised conditions to improve the crystal properties and/or the growth yield. A promising option is to apply an axially travelling magnetic wave to the melt (Travelling Magnetic Field - TMF). It introduces a mainly axial Lorentz force, which leads to meridional flow patterns. In recent numerical studies te{3}, te{6} the TMF has been recognised to be a versatile and efficient tool to control the heat and mass transport in the melt. For the Vertical Bridgman/Vertical Gradient Freeze (VB/VGF) growth, the beneficial effect of an adequately adjusted TMF-induced flow was clearly demonstrated in te{6} in terms of the reduction of thermal shear stress at the solid-liquid interface. In this paper, we present experimental and numerical results on the TMF driven convection in an isothermal model fluid as well as first VGF-TMF crystal growth experiments. The model investigations are focused on the transition from laminar to instationary flow conditions that should be avoided in crystal growth applications. The VGF experiments were aimed at growing Ga doped germanium single crystals under the influence of the travelling field in a newly developed VGF-TMF equipment. Figs 4, Refs 10.

  18. Comparative analyses of spent nuclear fuel transport modal options: Transport options under existing site constraints

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brentlinger, L.A.; Hofmann, P.L.; Peterson, R.W.

    1989-08-01

    The movement of nuclear waste can be accomplished by various transport modal options involving different types of vehicles, transport casks, transport routes, and intermediate intermodal transfer facilities. A series of systems studies are required to evaluate modal/intermodal spent fuel transportation options in a consistent fashion. This report provides total life-cycle cost and life-cycle dose estimates for a series of transport modal options under existing site constraints. 14 refs., 7 figs., 28 tabs.

  19. Hypertension in pregnancy: natural history and treatment options.

    PubMed

    Foo, L; Tay, J; Lees, C C; McEniery, C M; Wilkinson, I B

    2015-05-01

    Hypertensive disorders of pregnancy affect approximately 5-10% of all maternities and are major contributors of maternal and neonatal morbidity and mortality worldwide. This group of disorders encompasses chronic hypertension, as well as conditions that arise de novo in pregnancy: gestational hypertension and pre-eclampsia. The latter group is thought to be part of the same continuum but with arbitrary division. Research into the aetiology of hypertension in pregnancy have largely been focused on pre-eclampsia, with a majority of studies exploring either pregnancy-associated factors such as placental-derived or immunologic responses to pregnancy tissue, or maternal constitutional factors such as cardiovascular health and endothelial dysfunction. The evidence base for the pathophysiology and progression of hypertensive disorders in pregnancy, particularly pre-eclampsia, is reviewed. Clinical algorithms and pharmacological agents for the management of hypertension in pregnancy are summarised, with a brief focus on post-partum considerations and long-term health implications. Novel therapeutic options for the management of pre-eclampsia are also explored.

  20. Magnetic-confinement fusion

    NASA Astrophysics Data System (ADS)

    Ongena, J.; Koch, R.; Wolf, R.; Zohm, H.

    2016-05-01

    Our modern society requires environmentally friendly solutions for energy production. Energy can be released not only from the fission of heavy nuclei but also from the fusion of light nuclei. Nuclear fusion is an important option for a clean and safe solution for our long-term energy needs. The extremely high temperatures required for the fusion reaction are routinely realized in several magnetic-fusion machines. Since the early 1990s, up to 16 MW of fusion power has been released in pulses of a few seconds, corresponding to a power multiplication close to break-even. Our understanding of the very complex behaviour of a magnetized plasma at temperatures between 150 and 200 million °C surrounded by cold walls has also advanced substantially. This steady progress has resulted in the construction of ITER, a fusion device with a planned fusion power output of 500 MW in pulses of 400 s. ITER should provide answers to remaining important questions on the integration of physics and technology, through a full-size demonstration of a tenfold power multiplication, and on nuclear safety aspects. Here we review the basic physics underlying magnetic fusion: past achievements, present efforts and the prospects for future production of electrical energy. We also discuss questions related to the safety, waste management and decommissioning of a future fusion power plant.

  1. 48 CFR 536.270 - Exercise of options.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 4 2010-10-01 2010-10-01 false Exercise of options. 536... Construction 536.270 Exercise of options. (a) If exercising an option, notify the contractor, in writing, within the time period specified in the contract. (b) Exercise options only after determining that all...

  2. 48 CFR 3417.207 - Exercise of options.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 7 2010-10-01 2010-10-01 false Exercise of options. 3417... REGULATION CONTRACTING METHODS AND CONTRACT TYPES SPECIAL CONTRACTING METHODS Options 3417.207 Exercise of options. If any provision in a contract requires that an option may only be exercised within a specified...

  3. 48 CFR 817.202 - Use of options.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 5 2010-10-01 2010-10-01 false Use of options. 817.202... AND CONTRACT TYPES SPECIAL CONTRACTING METHODS Options 817.202 Use of options. All solicitations... four one-year renewal options as prescribed in FAR Subpart 17.2. The contracting officer must forward...

  4. 48 CFR 317.207 - Exercise of options.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 48 Federal Acquisition Regulations System 4 2012-10-01 2012-10-01 false Exercise of options. 317... METHODS AND CONTRACT TYPES SPECIAL CONTRACTING METHODS Options 317.207 Exercise of options. (h) Before..., and the Section 508 Official or designee, prior to exercise of an option. The Contracting Officer...

  5. 48 CFR 17.207 - Exercise of options.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 48 Federal Acquisition Regulations System 1 2012-10-01 2012-10-01 false Exercise of options. 17... METHODS AND CONTRACT TYPES SPECIAL CONTRACTING METHODS Options 17.207 Exercise of options. (a) When... exercise options only after determining that— (1) Funds are available; (2) The requirement covered by the...

  6. 48 CFR 317.207 - Exercise of options.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 48 Federal Acquisition Regulations System 4 2013-10-01 2013-10-01 false Exercise of options. 317... METHODS AND CONTRACT TYPES SPECIAL CONTRACTING METHODS Options 317.207 Exercise of options. (h) Before..., and the Section 508 Official or designee, prior to exercise of an option. The Contracting Officer...

  7. 48 CFR 17.207 - Exercise of options.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 48 Federal Acquisition Regulations System 1 2014-10-01 2014-10-01 false Exercise of options. 17... METHODS AND CONTRACT TYPES SPECIAL CONTRACTING METHODS Options 17.207 Exercise of options. (a) When... exercise options only after determining that— (1) Funds are available; (2) The requirement covered by the...

  8. 48 CFR 536.270 - Exercise of options.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 48 Federal Acquisition Regulations System 4 2013-10-01 2013-10-01 false Exercise of options. 536... Construction 536.270 Exercise of options. (a) If exercising an option, notify the contractor, in writing, within the time period specified in the contract. (b) Exercise options only after determining that all...

  9. 48 CFR 536.270 - Exercise of options.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 48 Federal Acquisition Regulations System 4 2011-10-01 2011-10-01 false Exercise of options. 536... Construction 536.270 Exercise of options. (a) If exercising an option, notify the contractor, in writing, within the time period specified in the contract. (b) Exercise options only after determining that all...

  10. 48 CFR 317.207 - Exercise of options.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 48 Federal Acquisition Regulations System 4 2011-10-01 2011-10-01 false Exercise of options. 317... METHODS AND CONTRACT TYPES SPECIAL CONTRACTING METHODS Options 317.207 Exercise of options. (h) Before..., and the Section 508 Official or designee, prior to exercise of an option. The Contracting Officer...

  11. 48 CFR 317.207 - Exercise of options.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 48 Federal Acquisition Regulations System 4 2014-10-01 2014-10-01 false Exercise of options. 317... METHODS AND CONTRACT TYPES SPECIAL CONTRACTING METHODS Options 317.207 Exercise of options. (h) Before..., and the Section 508 Official or designee, prior to exercise of an option. The Contracting Officer...

  12. 48 CFR 17.207 - Exercise of options.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 48 Federal Acquisition Regulations System 1 2013-10-01 2013-10-01 false Exercise of options. 17... METHODS AND CONTRACT TYPES SPECIAL CONTRACTING METHODS Options 17.207 Exercise of options. (a) When... exercise options only after determining that— (1) Funds are available; (2) The requirement covered by the...

  13. 48 CFR 17.207 - Exercise of options.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 48 Federal Acquisition Regulations System 1 2011-10-01 2011-10-01 false Exercise of options. 17... METHODS AND CONTRACT TYPES SPECIAL CONTRACTING METHODS Options 17.207 Exercise of options. (a) When... exercise options only after determining that— (1) Funds are available; (2) The requirement covered by the...

  14. 48 CFR 536.270 - Exercise of options.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 48 Federal Acquisition Regulations System 4 2012-10-01 2012-10-01 false Exercise of options. 536... Construction 536.270 Exercise of options. (a) If exercising an option, notify the contractor, in writing, within the time period specified in the contract. (b) Exercise options only after determining that all...

  15. 48 CFR 536.270 - Exercise of options.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 48 Federal Acquisition Regulations System 4 2014-10-01 2014-10-01 false Exercise of options. 536... Construction 536.270 Exercise of options. (a) If exercising an option, notify the contractor, in writing, within the time period specified in the contract. (b) Exercise options only after determining that all...

  16. The triathlon of magnetic actuation: Rolling, propelling, swimming with a single magnetic material

    PubMed Central

    Vach, Peter J.; Faivre, Damien

    2015-01-01

    Magnetic actuation of microscopic devices in a liquid environment has been achieved in various ways, which can be grouped into rolling, propelling and swimming. Previous actuators were designed with a focus on one particular type of magnetic actuation. We have shown earlier that efficient magnetic propellers can be selected from randomly shaped magnetic nanostructures synthesized in solution. Here we show that these synthesized nanostructures can be used for all three types of magnetic actuation. Whereas it might not be surprising that single structures can roll in addition to propelling, swimming is unexpectedly also observed using the same material. In this case, however, the magnetically guided self-assembly of several individual particles into chain-like structures is necessary to obtain swimmers, since individual rigid nanostructures cannot swim. Interestingly, the direction of the swimming motion is not necessarily parallel to the long axis of the chain-like assembly, a finding that had been theoretically expected but experimentally not observed so far. Our findings show that the range of structures that can be effectively actuated by external magnetic fields is much broader than assumed until now. This could open up new opportunities for the design of magnetically actuated devices. PMID:25791721

  17. Novel magnet-retained prosthetic system for facial reconstruction.

    PubMed

    Ahmed, Mostafa M; Piper, James M; Hansen, Nancy A; Sutton, Alan J; Schmalbach, Cecelia E

    2014-01-01

    Traumatic facial defects negatively impact speech, mastication, deglutition, dental hygiene, and psychosocial well-being. Reconstruction must address restoration of function and aesthetics to provide quality of life. This report describes soft-tissue reconstruction using a novel magnet-retained facial prosthesis without osseointegrated abutments, performed in a patient after traumatic loss of the entire left lower part of the face, including lips, commissure, and mentum. This reconstructive technique successfully addressed the cosmetic defect while also restoring function with respect to speech and oral nutrition. For this reason, magnet-retained facial prosthesis should be added to free tissue transfer and regional flaps as a reasonable option in the reconstructive algorithm for complex soft-tissue defects of the lower face.

  18. Health facility challenges to the provision of Option B+ in western Kenya: a qualitative study

    PubMed Central

    Akama, Eliud; Bukusi, Elizabeth A; Musoke, Pamela; Nalwa, Wafula Z; Odeny, Thomas A; Onono, Maricianah; Spangler, Sydney A; Turan, Janet M; Wanga, Iris; Abuogi, Lisa L

    2017-01-01

    Current WHO guidelines recommend lifelong antiretroviral therapy (ART) for all HIV-positive individuals, including pregnant and breastfeeding women (Option B+) in settings with generalized HIV epidemics. While Option B+ is scaled-up in Kenya, insufficient adherence and retention to care could undermine the expected positive impact of Option B+. To explore challenges to the provision of Option B+ at the health facility level, we conducted forty individual gender-matched in-depth interviews with HIV-positive pregnant/postpartum women and their male partners, and four focus groups with thirty health care providers at four health facilities in western Kenya between September-November 2014. Transcripts were coded with the Dedoose software using a coding framework based on the literature, topics from interview guides, and emerging themes from transcripts. Excerpts from broad codes were then fine-coded using an inductive approach. Three major themes emerged: 1) Option B+ specific challenges (same-day initiation into treatment, health care providers unconvinced of the benefits of Option B+, insufficient training); 2) facility resource constraints (staff and drug shortages, long queues, space limitations); and 3) lack of client-friendly services (scolding of patients, inconvenient operating hours, lack of integration of services, administrative requirements). This study highlights important challenges at the health facility level related to Option B+ rollout in western Kenya. Addressing these specific challenges may increase linkage, retention and adherence to life-long ART treatment for pregnant HIV-positive women in Kenya, contribute towards elimination of mother-to-child HIV transmission, and improve maternal and child outcomes. PMID:28207061

  19. Health facility challenges to the provision of Option B+ in western Kenya: a qualitative study.

    PubMed

    Helova, Anna; Akama, Eliud; Bukusi, Elizabeth A; Musoke, Pamela; Nalwa, Wafula Z; Odeny, Thomas A; Onono, Maricianah; Spangler, Sydney A; Turan, Janet M; Wanga, Iris; Abuogi, Lisa L

    2017-03-01

    Current WHO guidelines recommend lifelong antiretroviral therapy (ART) for all HIV-positive individuals, including pregnant and breastfeeding women (Option B+) in settings with generalized HIV epidemics. While Option B+ is scaled-up in Kenya, insufficient adherence and retention to care could undermine the expected positive impact of Option B+. To explore challenges to the provision of Option B+ at the health facility level, we conducted forty individual gender-matched in-depth interviews with HIV-positive pregnant/postpartum women and their male partners, and four focus groups with thirty health care providers at four health facilities in western Kenya between September-November 2014. Transcripts were coded with the Dedoose software using a coding framework based on the literature, topics from interview guides, and emerging themes from transcripts. Excerpts from broad codes were then fine-coded using an inductive approach. Three major themes emerged: 1) Option B+ specific challenges (same-day initiation into treatment, health care providers unconvinced of the benefits of Option B+, insufficient training); 2) facility resource constraints (staff and drug shortages, long queues, space limitations); and 3) lack of client-friendly services (scolding of patients, inconvenient operating hours, lack of integration of services, administrative requirements). This study highlights important challenges at the health facility level related to Option B+ rollout in western Kenya. Addressing these specific challenges may increase linkage, retention and adherence to life-long ART treatment for pregnant HIV-positive women in Kenya, contribute towards elimination of mother-to-child HIV transmission, and improve maternal and child outcomes.

  20. Five-year multicenter study of magnetic attachments used for natural overdenture abutments.

    PubMed

    Gonda, T; Yang, T C; Maeda, Y

    2013-04-01

    The purpose of this study was to examine a longitudinal clinical performance of magnetic attachments used for natural overdenture abutments. The study included 131 patients who had used removable prostheses (complete overdentures 31%, partial dentures 69%) more than 5 years (40-90 years old) with 211 magnetic attachments on natural abutments (Magfit 400 or 600; Aichi Steel co., Aichi, Japan) treated in 15 clinics using a standardized protocol. Analyses were performed on the degree of patient satisfaction regarding retention, complications of magnets (corrosion, detachment from denture base), abutments (pain during mastication, periodontal pocket formation, inflammation, mobility), and dentures (fracture etc.). Ninety-seven percent of patients were satisfied with the retention and stability of their dentures. No corrosion of magnet was observed, and 19 magnets were detached. Most frequent complication of abutments was periodontal pocket formation (52%), followed by the inflammation (29%), increase in mobility (27%) and pain (4%). Magnetic attachment on natural tooth abutments provided a viable and long-term treatment option. © 2013 Blackwell Publishing Ltd.

  1. 48 CFR 517.202 - Use of options.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 4 2010-10-01 2010-10-01 false Use of options. 517.202... AND CONTRACT TYPES SPECIAL CONTRACTING METHODS Options 517.202 Use of options. (a) Supplies or services. (1) You should use options when they meet one or more of the following objectives: (i) Reduce...

  2. 48 CFR 17.202 - Use of options.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 1 2010-10-01 2010-10-01 false Use of options. 17.202... AND CONTRACT TYPES SPECIAL CONTRACTING METHODS Options 17.202 Use of options. (a) Subject to the..., the contracting officer may include options in contracts when it is in the Government's interest. When...

  3. 32 CFR 644.168 - Exercise of options.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 32 National Defense 4 2014-07-01 2013-07-01 true Exercise of options. 644.168 Section 644.168... Exercise of options. Upon issuance of a real estate directive for acquisition of the optioned real property, the District or Division Engineer will exercise the option and proceed with the acquisition in...

  4. 32 CFR 644.168 - Exercise of options.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 32 National Defense 4 2011-07-01 2011-07-01 false Exercise of options. 644.168 Section 644.168... Exercise of options. Upon issuance of a real estate directive for acquisition of the optioned real property, the District or Division Engineer will exercise the option and proceed with the acquisition in...

  5. 32 CFR 644.168 - Exercise of options.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 32 National Defense 4 2012-07-01 2011-07-01 true Exercise of options. 644.168 Section 644.168... Exercise of options. Upon issuance of a real estate directive for acquisition of the optioned real property, the District or Division Engineer will exercise the option and proceed with the acquisition in...

  6. 32 CFR 644.168 - Exercise of options.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 32 National Defense 4 2013-07-01 2013-07-01 false Exercise of options. 644.168 Section 644.168... Exercise of options. Upon issuance of a real estate directive for acquisition of the optioned real property, the District or Division Engineer will exercise the option and proceed with the acquisition in...

  7. 32 CFR 644.168 - Exercise of options.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 32 National Defense 4 2010-07-01 2010-07-01 true Exercise of options. 644.168 Section 644.168... ESTATE HANDBOOK Acquisition Procurement of Options Prior to Real Estate Directives (military) § 644.168 Exercise of options. Upon issuance of a real estate directive for acquisition of the optioned real property...

  8. 48 CFR 217.207 - Exercise of options.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 3 2010-10-01 2010-10-01 false Exercise of options. 217..., DEPARTMENT OF DEFENSE CONTRACTING METHODS AND CONTRACT TYPES SPECIAL CONTRACTING METHODS Options 217.207 Exercise of options. (c) In addition to the requirements at FAR 17.207(c), exercise an option only after...

  9. Correlative Magnetic Imaging of Heat-Assisted Magnetic Recording Media in Cross Section Using Lorentz TEM and MFM

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kim, Taeho Roy; Phatak, Charudatta; Petford-Long, Amanda K.

    In order to increase the storage density of hard disk drives, a detailed understanding of the magnetic structure of the granular magnetic layer is essential. Here, we demonstrate an experimental procedure of imaging recorded bits on heat-assisted magnetic recording (HAMR) media in cross section using Lorentz transmission electron microscopy (TEM). With magnetic force microscopy and focused ion beam (FIB), we successfully targeted a single track to prepare cross-sectional TEM specimens. Then, we characterized the magnetic structure of bits with their precise location and orientation using Fresnel mode of Lorentz TEM. Here, this method can promote understanding of the correlation betweenmore » bits and their material structure in HAMR media to design better the magnetic layer.« less

  10. Correlative Magnetic Imaging of Heat-Assisted Magnetic Recording Media in Cross Section Using Lorentz TEM and MFM

    DOE PAGES

    Kim, Taeho Roy; Phatak, Charudatta; Petford-Long, Amanda K.; ...

    2017-10-23

    In order to increase the storage density of hard disk drives, a detailed understanding of the magnetic structure of the granular magnetic layer is essential. Here, we demonstrate an experimental procedure of imaging recorded bits on heat-assisted magnetic recording (HAMR) media in cross section using Lorentz transmission electron microscopy (TEM). With magnetic force microscopy and focused ion beam (FIB), we successfully targeted a single track to prepare cross-sectional TEM specimens. Then, we characterized the magnetic structure of bits with their precise location and orientation using Fresnel mode of Lorentz TEM. Here, this method can promote understanding of the correlation betweenmore » bits and their material structure in HAMR media to design better the magnetic layer.« less

  11. Annealing effects on magnetic properties of silicone-coated iron-based soft magnetic composites

    NASA Astrophysics Data System (ADS)

    Wu, Shen; Sun, Aizhi; Zhai, Fuqiang; Wang, Jin; Zhang, Qian; Xu, Wenhuan; Logan, Philip; Volinsky, Alex A.

    2012-03-01

    This paper focuses on novel iron-based soft magnetic composites synthesis utilizing high thermal stability silicone resin to coat iron powder. The effect of an annealing treatment on the magnetic properties of synthesized magnets was investigated. The coated silicone insulating layer was characterized by scanning electron microscopy and energy dispersive X-ray spectroscopy. Silicone uniformly coated the powder surface, resulting in a reduction of the imaginary part of the permeability, thereby increasing the electrical resistivity and the operating frequency of the synthesized magnets. The annealing treatment increased the initial permeability, the maximum permeability, and the magnetic induction, and decreased the coercivity. Annealing at 580 °C increased the maximum permeability by 72.5%. The result of annealing at 580 °C shows that the ferromagnetic resonance frequency increased from 2 kHz for conventional epoxy resin coated samples to 80 kHz for the silicone resin insulated composites.

  12. Electron Beam Focusing in the Linear Accelerator (linac)

    NASA Astrophysics Data System (ADS)

    Jauregui, Luis

    2015-10-01

    To produce consistent data with an electron accelerator, it is critical to have a well-focused beam. To keep the beam focused, quadrupoles (quads) are employed. Quads are magnets, which focus the beam in one direction (x or y) and defocus in the other. When two or more quads are used in series, a net focusing effect is achieved in both vertical and horizontal directions. At start up there is a 5% calibration error in the linac at Thomas Jefferson National Accelerator Facility. This means that the momentum of particles passing through the quads isn't always what is expected, which affects the focusing of the beam. The objective is to find exactly how sensitive the focusing in the linac is to this 5% error. A linac was simulated, which contained 290 RF Cavities with random electric fields (to simulate the 5% calibration error), and a total momentum kick of 1090 MeV. National Science Foundation, Department of Energy, Jefferson Lab, Old Dominion University.

  13. 24 CFR 221.775 - Option period.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 24 Housing and Urban Development 2 2010-04-01 2010-04-01 false Option period. 221.775 Section 221.775 Housing and Urban Development Regulations Relating to Housing and Urban Development (Continued... § 221.775 Option period. The mortgagee may exercise its option to assign within one year following the...

  14. 24 CFR 221.770 - Assignment option.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 24 Housing and Urban Development 2 2010-04-01 2010-04-01 false Assignment option. 221.770 Section... § 221.770 Assignment option. A mortgagee holding a conditional or firm commitment issued on or before... mortgagee's approved underwriter on or before November 30, 1983) has the option to assign, transfer and...

  15. 48 CFR 2917.202 - Use of options.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 7 2010-10-01 2010-10-01 false Use of options. 2917.202... CONTRACT TYPES SPECIAL CONTRACTING METHODS Options 2917.202 Use of options. The HCA may, in unusual circumstances, approve option quantities in excess of the 50 percent limit prescribed in FAR 17.203(g)(2). The...

  16. Pricing foreign equity option with stochastic volatility

    NASA Astrophysics Data System (ADS)

    Sun, Qi; Xu, Weidong

    2015-11-01

    In this paper we propose a general foreign equity option pricing framework that unifies the vast foreign equity option pricing literature and incorporates the stochastic volatility into foreign equity option pricing. Under our framework, the time-changed Lévy processes are used to model the underlying assets price of foreign equity option and the closed form pricing formula is obtained through the use of characteristic function methodology. Numerical tests indicate that stochastic volatility has a dramatic effect on the foreign equity option prices.

  17. Roadwaste : Issues and Options : appendices.

    DOT National Transportation Integrated Search

    1998-06-01

    The appendices belong to "Roadwaste : Issues and Options". : The Oregon Department of Transportation (ODOT) is conducting a study to determine roadwaste management options. Phase 1 consisted of a thorough review of regulations and standards, roadwast...

  18. 24 CFR 221.255 - Assignment option.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 24 Housing and Urban Development 2 2010-04-01 2010-04-01 false Assignment option. 221.255 Section... Assignment option. (a) A mortgagee holding a mortgage insured pursuant to a conditional or firm commitment issued on or before November 30, 1983 has the option to assign, transfer and deliver to the Commissioner...

  19. Expensing stock options: a fair-value approach.

    PubMed

    Kaplan, Robert S; Palepu, Krishna G

    2003-12-01

    Now that companies such as General Electric and Citigroup have accepted the premise that employee stock options are an expense, the debate is shifting from whether to report options on income statements to how to report them. The authors present a new accounting mechanism that maintains the rationale underlying stock option expensing while addressing critics' concerns about measurement error and the lack of reconciliation to actual experience. A procedure they call fair-value expensing adjusts and eventually reconciles cost estimates made at grant date with subsequent changes in the value of the options, and it does so in a way that eliminates forecasting and measurement errors over time. The method captures the chief characteristic of stock option compensation--that employees receive part of their compensation in the form of a contingent claim on the value they are helping to produce. The mechanism involves creating entries on both the asset and equity sides of the balance sheet. On the asset side, companies create a prepaid-compensation account equal to the estimated cost of the options granted; on the owners'-equity side, they create a paid-in capital stock-option account for the same amount. The prepaid-compensation account is then expensed through the income statement, and the stock option account is adjusted on the balance sheet to reflect changes in the estimated fair value of the granted options. The amortization of prepaid compensation is added to the change in the option grant's value to provide the total reported expense of the options grant for the year. At the end of the vesting period, the company uses the fair value of the vested option to make a final adjustment on the income statement to reconcile any difference between that fair value and the total of the amounts already reported.

  20. 48 CFR 252.217-7001 - Surge option.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 3 2010-10-01 2010-10-01 false Surge option. 252.217-7001... Clauses 252.217-7001 Surge option. As prescribed in 217.208-70(b), use the following clause: Surge Option (AUG 1992) (a) General. The Government has the option to— (1) Increase the quantity of supplies or...

  1. 48 CFR 217.202 - Use of options.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 3 2010-10-01 2010-10-01 false Use of options. 217.202... OF DEFENSE CONTRACTING METHODS AND CONTRACT TYPES SPECIAL CONTRACTING METHODS Options 217.202 Use of options. (1) See PGI 217.202 for guidance on the use of options. (2) See 234.005-1 for limitations on the...

  2. Electrostatic focusing of directly heated linear filament gun using EGUN

    NASA Astrophysics Data System (ADS)

    Iqbal, Munawar; Lodhi, M. A. K.; Majeed, Zahid; Batani, Dimitri

    2011-06-01

    This paper presents the optimization of a line source rectangular electron gun using electrostatic focusing. We optimized the gun by shaping the configuration of its electrodes in order to achieve the desired focusing characteristics, namely maximum focusing distance and minimum beam spread. The optimization has been carried out using the software EGUN. We have also simplified the gun design using only one focusing electrode at the same potential as that of the cathode and by avoiding magnetic focusing field, separate focusing electrodes and additional power supply, thus minimizing the cost without any loss in its accuracy and efficient performance. This gun with the optimum configuration was used in actual experiment and the results of the simulation were compared with the experimental measurements.

  3. Superconducting focusing lenses for the SSR-1 cryomodule of PXIE test stand at Fermilab

    DOE PAGES

    DiMarco, J.; Tartaglia, M.; Terechkine, I.

    2016-12-05

    Five solenoid-based focusing lenses designed for use inside the SSR1 cryomodule of the PXIE test stand at Fermilab have been fabricated and tested. In addition to a focusing solenoid, each lens is equipped with a set of windings that generate magnetic field in the transverse plane and can be used in the steering dipole mode or as a skew quadrupole corrector. The lenses will be installed between superconducting cavities in the cryomodule, so getting sufficiently low fringe magnetic field was one of the main design requirements. Beam dynamics simulations indicated a need for high accuracy positioning of the lenses inmore » the cryomodule, which triggered a study towards understanding uncertainties of the magnetic axis position relative to the geometric features of the lens. Furthermore, this report summarizes the efforts towards certification of the lenses, including results of performance tests, fringe field data, and uncertainty of the magnetic axis position.« less

  4. Superconducting focusing lenses for the SSR-1 cryomodule of PXIE test stand at Fermilab

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    DiMarco, J.; Tartaglia, M.; Terechkine, I.

    Five solenoid-based focusing lenses designed for use inside the SSR1 cryomodule of the PXIE test stand at Fermilab have been fabricated and tested. In addition to a focusing solenoid, each lens is equipped with a set of windings that generate magnetic field in the transverse plane and can be used in the steering dipole mode or as a skew quadrupole corrector. The lenses will be installed between superconducting cavities in the cryomodule, so getting sufficiently low fringe magnetic field was one of the main design requirements. Beam dynamics simulations indicated a need for high accuracy positioning of the lenses inmore » the cryomodule, which triggered a study towards understanding uncertainties of the magnetic axis position relative to the geometric features of the lens. Furthermore, this report summarizes the efforts towards certification of the lenses, including results of performance tests, fringe field data, and uncertainty of the magnetic axis position.« less

  5. Technique to quantitatively measure magnetic properties of thin structures at <10 NM spatial resolution

    DOEpatents

    Bajt, Sasa

    2003-07-08

    A highly sensitive and high resolution magnetic microscope images magnetic properties quantitatively. Imaging is done with a modified transmission electron microscope that allows imaging of the sample in a zero magnetic field. Two images from closely spaced planes, one in focus and one slightly out of focus, are sufficient to calculate the absolute values of the phase change imparted to the electrons, and hence obtain the magnetization vector field distribution.

  6. The focus series: A collection of single-concept remote sensing educational materials

    NASA Technical Reports Server (NTRS)

    Davis, S. M.

    1977-01-01

    The FOCUS series is a collection of two-page foldout documents each consisting of a diagram or photograph and an extended option of three to four hundred words. The series was developed to present basic remote sensing concepts in a simple, concise way. Issues currently available are collected in this information note.

  7. Space station needs, attributes and architectural options: Architectural options and selection

    NASA Technical Reports Server (NTRS)

    Nelson, W. G.

    1983-01-01

    The approach, study results, and recommendations for defining and selecting space station architectural options are described. Space station system architecture is defined as the arrangement of elements (manned and unmanned on-orbit facilities, shuttle vehicles, orbital transfer vehicles, etc.), the number of these elements, their location (orbital inclination and altitude, and their functional performance capability, power, volume, crew, etc.). Architectural options are evaluated based on the degree of mission capture versus cost and required funding rate. Mission capture refers to the number of missions accommodated by the particular architecture.

  8. Multivariate data analysis and machine learning in Alzheimer's disease with a focus on structural magnetic resonance imaging.

    PubMed

    Falahati, Farshad; Westman, Eric; Simmons, Andrew

    2014-01-01

    Machine learning algorithms and multivariate data analysis methods have been widely utilized in the field of Alzheimer's disease (AD) research in recent years. Advances in medical imaging and medical image analysis have provided a means to generate and extract valuable neuroimaging information. Automatic classification techniques provide tools to analyze this information and observe inherent disease-related patterns in the data. In particular, these classifiers have been used to discriminate AD patients from healthy control subjects and to predict conversion from mild cognitive impairment to AD. In this paper, recent studies are reviewed that have used machine learning and multivariate analysis in the field of AD research. The main focus is on studies that used structural magnetic resonance imaging (MRI), but studies that included positron emission tomography and cerebrospinal fluid biomarkers in addition to MRI are also considered. A wide variety of materials and methods has been employed in different studies, resulting in a range of different outcomes. Influential factors such as classifiers, feature extraction algorithms, feature selection methods, validation approaches, and cohort properties are reviewed, as well as key MRI-based and multi-modal based studies. Current and future trends are discussed.

  9. Measurement method of magnetic field for the wire suspended micro-pendulum accelerometer.

    PubMed

    Lu, Yongle; Li, Leilei; Hu, Ning; Pan, Yingjun; Ren, Chunhua

    2015-04-13

    Force producer is one of the core components of a Wire Suspended Micro-Pendulum Accelerometer; and the stability of permanent magnet in the force producer determines the consistency of the acceleration sensor's scale factor. For an assembled accelerometer; direct measurement of magnetic field strength is not a feasible option; as the magnetometer probe cannot be laid inside the micro-space of the sensor. This paper proposed an indirect measurement method of the remnant magnetization of Micro-Pendulum Accelerometer. The measurement is based on the working principle of the accelerometer; using the current output at several different scenarios to resolve the remnant magnetization of the permanent magnet. Iterative Least Squares algorithm was used for the adjustment of the data due to nonlinearity of this problem. The calculated remnant magnetization was 1.035 T. Compared to the true value; the error was less than 0.001 T. The proposed method provides an effective theoretical guidance for measuring the magnetic field of the Wire Suspended Micro-Pendulum Accelerometer; correcting the scale factor and temperature influence coefficients; etc.

  10. Hyperhidrosis: review of recent advances and new therapeutic options for primary hyperhidrosis.

    PubMed

    Brown, Ashley L; Gordon, Jennifer; Hill, Samantha

    2014-08-01

    Primary focal hyperhidrosis is a common condition that negatively impacts quality of life for many pediatric patients and can be challenging to treat. Standard treatments for hyperhidrosis can be used with success in many patients, and newer therapies and techniques offer options that have demonstrated efficacy and safety. This review highlights standard therapies for primary focal hyperhidrosis as well as the most recent technique advancements and alternative treatment options. The standard approach to treating primary focal hyperhidrosis remains initiation of topical preparations, followed by advancement to systemic medications, local administration of medication and/or surgical procedures. Recent studies focus on enhancing tolerability of topical preparations as well as evaluating the efficacy of neuromodulator injections, oral anticholinergic medications and laser therapy. Microwave technology has also been introduced for the treatment of focal hyperhidrosis with promising results. Many therapies exist for hyperhidrosis, and each treatment plan must be evaluated on a patient-by-patient basis. Advances in standard therapies and emergence of new treatment techniques are the main emphases of current published literature on hyperhidrosis. This article presents recent therapeutic options as well as updates on more established strategies to help practitioners treat this challenging condition.

  11. On the accuracy potential of focused plenoptic camera range determination in long distance operation

    NASA Astrophysics Data System (ADS)

    Sardemann, Hannes; Maas, Hans-Gerd

    2016-04-01

    Plenoptic cameras have found increasing interest in optical 3D measurement techniques in recent years. While their basic principle is 100 years old, the development in digital photography, micro-lens fabrication technology and computer hardware has boosted the development and lead to several commercially available ready-to-use cameras. Beyond their popular option of a posteriori image focusing or total focus image generation, their basic ability of generating 3D information from single camera imagery depicts a very beneficial option for certain applications. The paper will first present some fundamentals on the design and history of plenoptic cameras and will describe depth determination from plenoptic camera image data. It will then present an analysis of the depth determination accuracy potential of plenoptic cameras. While most research on plenoptic camera accuracy so far has focused on close range applications, we will focus on mid and long ranges of up to 100 m. This range is especially relevant, if plenoptic cameras are discussed as potential mono-sensorial range imaging devices in (semi-)autonomous cars or in mobile robotics. The results show the expected deterioration of depth measurement accuracy with depth. At depths of 30-100 m, which may be considered typical in autonomous driving, depth errors in the order of 3% (with peaks up to 10-13 m) were obtained from processing small point clusters on an imaged target. Outliers much higher than these values were observed in single point analysis, stressing the necessity of spatial or spatio-temporal filtering of the plenoptic camera depth measurements. Despite these obviously large errors, a plenoptic camera may nevertheless be considered a valid option for the application fields of real-time robotics like autonomous driving or unmanned aerial and underwater vehicles, where the accuracy requirements decrease with distance.

  12. 45 CFR 1306.33 - Home-based program option.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 45 Public Welfare 4 2013-10-01 2013-10-01 false Home-based program option. 1306.33 Section 1306.33... PROGRAM HEAD START STAFFING REQUIREMENTS AND PROGRAM OPTIONS Head Start Program Options § 1306.33 Home-based program option. (a) Grantees implementing a home-based program option must: (1) Provide one home...

  13. 45 CFR 1306.33 - Home-based program option.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 45 Public Welfare 4 2014-10-01 2014-10-01 false Home-based program option. 1306.33 Section 1306.33... PROGRAM HEAD START STAFFING REQUIREMENTS AND PROGRAM OPTIONS Head Start Program Options § 1306.33 Home-based program option. (a) Grantees implementing a home-based program option must: (1) Provide one home...

  14. 45 CFR 1306.33 - Home-based program option.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 45 Public Welfare 4 2012-10-01 2012-10-01 false Home-based program option. 1306.33 Section 1306.33... PROGRAM HEAD START STAFFING REQUIREMENTS AND PROGRAM OPTIONS Head Start Program Options § 1306.33 Home-based program option. (a) Grantees implementing a home-based program option must: (1) Provide one home...

  15. In Vivo Targeted, Responsive, and Synergistic Cancer Nanotheranostics by Magnetic Resonance Imaging-Guided Synergistic High-Intensity Focused Ultrasound Ablation and Chemotherapy.

    PubMed

    Tang, Hailin; Guo, Yuan; Peng, Li; Fang, Hui; Wang, Zhigang; Zheng, Yuanyi; Ran, Haitao; Chen, Yu

    2018-05-09

    As one of the most representative noninvasive therapeutic modalities, high-intensity focused ultrasound (HIFU) has shown great promise for cancer therapy, but its low therapeutic efficacy and biosafety significantly hinder further extensive clinical translation and application. In this work, we report on the construction of a multifunctional theranostic nanoplatform to synergistically enhance the HIFU-therapeutic efficacy based on nanomedicine. A targeted and temperature-responsive theranostic nanoplatform (PFH/DOX@PLGA/Fe 3 O 4 -FA) has been designed and fabricated for efficient ultrasound/magnetic resonance dual-modality imaging-guided HIFU/chemo synergistic therapy. Especially, the folate was conjugated onto the surface of the nanoplatform for achieving active targeting to hepatoma cells by receptor-ligand interaction, which facilitates accumulation of the nanoplatforms into the tumor site. The integrated superparamagnetic iron oxide nanoparticles could generate the contrast enhancement in T 2 -weighted magnetic resonance imaging. By virtue of the thermal effect as generated by HIFU, liquid-gas phase transition of perfluorohexane (PFH) in nanocomposites was induced to generate PFH microbubbles, which achieved the contrast-enhanced ultrasound imaging and significantly improved the HIFU ablation efficacy. The loaded anticancer drugs could be released from the nanocomposites in a controllable manner (both pH and HIFU responsiveness). These multifunctional nanocomposites have been demonstrated to efficiently suppress the tumor growth based on the enhanced and synergistic chemotherapy and HIFU ablation, providing an efficient theranostic nanoplatform for cancer treatment.

  16. Self-focusing skyrmion racetracks in ferrimagnets

    NASA Astrophysics Data System (ADS)

    Kim, Se Kwon; Lee, Kyung-Jin; Tserkovnyak, Yaroslav

    2017-04-01

    We theoretically study the dynamics of ferrimagnetic skyrmions in inhomogeneous metallic films close to the angular momentum compensation point. In particular, it is shown that the line of the vanishing angular momentum can be utilized as a self-focusing racetrack for skyrmions. To that end, we begin by deriving the equations of motion for the dynamics of collinear ferrimagnets in the presence of a charge current. The obtained equations of motion reduce to those of ferromagnets and antiferromagnets at two special limits. In the collective coordinate approach, a skyrmion behaves as a massive charged particle moving in a viscous medium subjected to a magnetic field. Analogous to the snake orbits of electrons in a nonuniform magnetic field, we show that a ferrimagnet with nonuniform angular momentum density can exhibit the snake trajectories of skyrmions, which can be utilized as racetracks for skyrmions.

  17. Arcjet Tests of Different Gap-Filler Options for the Orion PICA Heatshield

    NASA Technical Reports Server (NTRS)

    Skokova, Kristina; Ellerby, Donald; Blosser, Max; Venkatapathy, Ethiraj; Bouslog, Stan; Reuther, James

    2009-01-01

    PICA (Phenolic Infiltrated Carbon Ablator) is one of the candidate thermal protection materials for the Orion vehicle. Because PICA is fabricated in blocks, gaps exist between the blocks, similar to the individual ceramic tiles of the Shuttle thermal protection system. The results of this work focus on arcjet test results of different gap-filler options for PICA, performed as part of the Orion TPS Advanced Development Project. The arcjet tests were performed at NASA Ames Research Center on stagnation models 4 inches in diameter at conditions representative of Orion flight conditions for both Lunar and Low Earth Orbit return. Performance of gap-filler options was evaluated based on the extent of backface temperature change, as compared to PICA without gaps, and on the extent of flow penetration into the gap, evident from the gap opening and widening.

  18. Vaginal Pessary for Uterine Repositioning During High-Intensity Focused Ultrasound Ablation of Uterine Leiomyomas

    PubMed Central

    Pulanic, Tajana Klepac; Venkatesan, Aradhana M.; Segars, James; Sokka, Sham; Wood, Bradford J.; Stratton, Pamela

    2015-01-01

    In order to ensure safe magnetic resonance-guided high-intensity focused ultrasound ablation of uterine leiomyomas, ultrasound beam path should be free of intervening scar and bowel. Pre-treatment magnetic resonance imaging of a 9cm long and 7.7cm wide leiomyomatous uterus in a 39-year-old woman with menorrhagia and abdominopelvic pain initially demonstrated a focused ultrasound treatment path without bowel between the uterus and abdominal wall. On the day of ablation, however, multiple loops of bowel were observed in the ultrasound beam path by magnetic resonance imaging. Uterine repositioning was accomplished with a 76 mm donut vaginal pessary which anteverted the fundus and successfully displaced bowel. A vaginal pessary may aid in repositioning an axial or retroverted uterus to enable ablation of uterine leiomyomas. PMID:26584482

  19. Transportation Options | Climate Neutral Research Campuses | NREL

    Science.gov Websites

    Transportation Options Transportation Options Transportation to, from, and within a research campus from business travel often enlarge the footprint more than expected. To understand options for climate

  20. Autoimmunity in focus: from mechanisms to treatment.

    PubMed

    Kon, Yujiro

    2012-05-01

    The 5th Asian Congress on Autoimmunity took place in Suntec City, Singapore, on the 17-19 November 2011 under the presidency of Yehuda Shoenfeld (Chaim Sheba Medical Center, Ramat Gan, Israel). Senior investigators from a range of fields--including immunology, autoimmunity, rheumatology, neurology and hepatology--attended the conference. The scientific program placed an emphasis on the pathogenesis, genetic basis and mechanistic aspects of autoimmune diseases, as well as their clinical outcomes and treatment options. Particular focus was placed on systemic lupus erythematosus, rheumatoid arthritis, Type I diabetes, antiphospholipid syndrome and autoimmune hepatitis. Participants from over 50 countries attended the conference.

  1. Have You Considered Accounting? Opportunities for Women Are Expanding. Career Options Series for Undergraduate Women.

    ERIC Educational Resources Information Center

    Rowes, Barbara

    This booklet is part of a set of self-guidance publications prepared by Catalyst, a national nonprofit organization. It is written specifically for undergraduate women to help them bring their aspirations into focus, develop realistic career goals and plan for career options in fields which, at the managerial and professional levels, have been…

  2. [The Abbreviated Injury Scale (AIS). Options and problems in application].

    PubMed

    Haasper, C; Junge, M; Ernstberger, A; Brehme, H; Hannawald, L; Langer, C; Nehmzow, J; Otte, D; Sander, U; Krettek, C; Zwipp, H

    2010-05-01

    The new AIS (Abbreviated Injury Scale) was released with an update by the AAAM (Association for the Advancement of Automotive Medicine) in 2008. It is a universal scoring system in the field of trauma applicable in clinic and research. In engineering it is used as a classification system for vehicle safety. The AIS can therefore be considered as an international, interdisciplinary and universal code of injury severity. This review focuses on a historical overview, potential applications and new coding options in the current version and also outlines the associated problems.

  3. Palm-size miniature superconducting bulk magnet

    NASA Astrophysics Data System (ADS)

    Saho, Norihide; Matsuda, Kazuya; Nishijima, Noriyo

    The development of a small, light, powerful and energy-efficient superconducting magnet has been desired in order to realize better efficiency and manipulability in guiding magnetic nano-particles, magnetic organic cells and other items to the right place. This study focuses on the development of a high-temperature superconducting (HTS) bulk magnet characterized by comparatively low leak magnetism despite a relatively high magnetic field. On this basis, the authors developed a palm-sized superconducting bulk magnet, which is the world's smallest, lightest, and lowest power consuming, as well as a new technology to effectively magnetize such a bulk magnet in a compact Stirling-cycle cryocooler (magnet C) with a pre-magnetized HTS bulk magnet (magnet B) in a compact cryocooler. This technology is demonstrated in two steps. In the first step, magnet B is magnetized using a superconducting solenoid magnet with a high magnetic field (magnet A) via the field cooling method. In the second step, magnet C is magnetized in the high magnetic field of magnet B. The prototype magnet C weighs 1.8 kg, and measures 235 × 65 × 115 mm (L × W × H). Magnet B was magnetized to 4.9 T using a 5 T magnet, and the target, magnet C, was magnetized using magnet B so that its maximum trapped magnetic flux density reached the value of 3.15 T. The net power consumption in a steady cooling state was 23 W, which is very low and comparable to that of a laptop computer.

  4. Magnetism in nanoparticles: tuning properties with coatings.

    PubMed

    Crespo, Patricia; de la Presa, Patricia; Marín, Pilar; Multigner, Marta; Alonso, José María; Rivero, Guillermo; Yndurain, Félix; González-Calbet, José María; Hernando, Antonio

    2013-12-04

    This paper reviews the effect of organic and inorganic coatings on magnetic nanoparticles. The ferromagnetic-like behaviour observed in nanoparticles constituted by materials which are non-magnetic in bulk is analysed for two cases: (a) Pd and Pt nanoparticles, formed by substances close to the onset of ferromagnetism, and (b) Au and ZnO nanoparticles, which were found to be surprisingly magnetic at the nanoscale when coated by organic surfactants. An overview of theories accounting for this unexpected magnetism, induced by the nanosize influence, is presented. In addition, the effect of coating magnetic nanoparticles with biocompatible metals, oxides or organic molecules is also reviewed, focusing on their applications.

  5. Calculation and Analysis of magnetic gradient tensor components of global magnetic models

    NASA Astrophysics Data System (ADS)

    Schiffler, Markus; Queitsch, Matthias; Schneider, Michael; Stolz, Ronny; Krech, Wolfram; Meyer, Hans-Georg; Kukowski, Nina

    2014-05-01

    Magnetic mapping missions like SWARM and its predecessors, e.g. the CHAMP and MAGSAT programs, offer high resolution Earth's magnetic field data. These datasets are usually combined with magnetic observatory and survey data, and subject to harmonic analysis. The derived spherical harmonic coefficients enable magnetic field modelling using a potential series expansion. Recently, new instruments like the JeSSY STAR Full Tensor Magnetic Gradiometry system equipped with very high sensitive sensors can directly measure the magnetic field gradient tensor components. The full understanding of the quality of the measured data requires the extension of magnetic field models to gradient tensor components. In this study, we focus on the extension of the derivation of the magnetic field out of the potential series magnetic field gradient tensor components and apply the new theoretical framework to the International Geomagnetic Reference Field (IGRF) and the High Definition Magnetic Model (HDGM). The gradient tensor component maps for entire Earth's surface produced for the IGRF show low values and smooth variations reflecting the core and mantle contributions whereas those for the HDGM gives a novel tool to unravel crustal structure and deep-situated ore bodies. For example, the Thor Suture and the Sorgenfrei-Thornquist Zone in Europe are delineated by a strong northward gradient. Derived from Eigenvalue decomposition of the magnetic gradient tensor, the scaled magnetic moment, normalized source strength (NSS) and the bearing of the lithospheric sources are presented. The NSS serves as a tool for estimating the lithosphere-asthenosphere boundary as well as the depth of plutons and ore bodies. Furthermore changes in magnetization direction parallel to the mid-ocean ridges can be obtained from the scaled magnetic moment and the normalized source strength discriminates the boundaries between the anomalies of major continental provinces like southern Africa or the Eastern European

  6. Magnetic Stimulation Therapy in Patients with COPD: A Systematic Review.

    PubMed

    Polastri, Massimiliano; Comellini, Vittoria; Pacilli, Angela Maria Grazia; Nava, Stefano

    2018-03-20

    Magnetotherapy (MT) is a therapeutic treatment based on the use of magnetic fields (MF) that can have an anti-inflammatory and analgesic effect. MT represents a possible treatment or an ancillary therapeutic intervention for a wide range of diseases and it is often used in the field of physiotherapeutic practices. A crucial point in the treatment of chronic obstructive pulmonary disease (COPD) patients, to counteract muscular depletion and respiratory symptoms, is represented by physiotherapy. Nevertheless, the knowledge about the application of MF as a therapeutic option in COPD patients is very limited. The purpose of the present study was to define what is currently known about the use of MF in patients with COPD. A systematic review of the literature was conducted during the month of October 2017, searching three main databases. Only those citations providing detailed informations about the use of MF to treat COPD symptoms either during an acute or a chronic phase of the disease, were selected. Following the selection process three articles were included in the final analysis. The present review focused on a total of thirty-six patients with COPD, and on the effects of the application of MF. In the majority of cases, the treatment sessions with MF were carried-out in an outpatient setting, and they differed with regard to the duration; frequency of application; dosage; intensity of the applied MF. Basing on the available informations, it seems that MF is a feasible, well tolerated, safe therapeutic option, for the treatment of motor-related COPD symptoms.

  7. Fertility concerns in men with genitourinary malignancies: Treatment dilemmas, fertility options, and medicolegal considerations.

    PubMed

    Polland, Allison; Berookhim, Boback M

    2016-09-01

    With increasing genitourinary cancer survivorship in patients of reproductive age, fertility preservation has become a greater focus in the management of these patients. We performed a review of articles pertaining to male infertility, fertility preservation, and genitourinary cancers. The aim was to review causes of infertility in patients with cancer, current options for fertility preservation, research that may expand preservation options, and ethical as well as medicolegal considerations. There are multiple causes of infertility in male patients with cancer, including the malignancy itself, and the treatments required to achieve a potential cure. Surgery can affect the normal pathways for erection, emission, and ejaculation. Chemotherapy can have a profound negative effect on spermatogenesis by causing chromosomal aberrations, maturation arrest, mutagenesis, and impaired spermatozoa motility. Radiation can cause cellular apoptosis with resultant reduction in spermatogonial stem cells. There are numerous methods to secure fertility before cancer treatment with the aid of cryopreservation ranging from simple patient-provided semen samples to complex sperm retrieval techniques. Research in the field of spermatogenic stem cells may lead to improved treatment options such as autotransplant of stem cells for repopulation of the testes after cancer treatment. Early discussion of possible fertility effects in patients undergoing genitourinary cancer treatment is critical in this era of increasing survivorship. Although current cancer treatments can cause infertility, there are well-established options for fertility preservation and current research will likely lead to improved treatment options. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. Nuclear magnetic resonance in high magnetic field: Application to condensed matter physics

    NASA Astrophysics Data System (ADS)

    Berthier, Claude; Horvatić, Mladen; Julien, Marc-Henri; Mayaffre, Hadrien; Krämer, Steffen

    2017-05-01

    In this review, we describe the potentialities offered by the nuclear magnetic resonance (NMR) technique to explore at a microscopic level new quantum states of condensed matter induced by high magnetic fields. We focus on experiments realised in resistive (up to 34 T) or hybrid (up to 45 T) magnets, which open a large access to these quantum phase transitions. After an introduction on NMR observables, we consider several topics: quantum spin systems (spin-Peierls transition, spin ladders, spin nematic phases, magnetisation plateaus, and Bose-Einstein condensation of triplet excitations), the field-induced charge density wave (CDW) in high-Tc superconductors, and exotic superconductivity including the Fulde-Ferrel-Larkin-Ovchinnikov superconducting state and the field-induced superconductivity due to the Jaccarino-Peter mechanism.

  9. Feynman path integral application on deriving black-scholes diffusion equation for european option pricing

    NASA Astrophysics Data System (ADS)

    Utama, Briandhika; Purqon, Acep

    2016-08-01

    Path Integral is a method to transform a function from its initial condition to final condition through multiplying its initial condition with the transition probability function, known as propagator. At the early development, several studies focused to apply this method for solving problems only in Quantum Mechanics. Nevertheless, Path Integral could also apply to other subjects with some modifications in the propagator function. In this study, we investigate the application of Path Integral method in financial derivatives, stock options. Black-Scholes Model (Nobel 1997) was a beginning anchor in Option Pricing study. Though this model did not successfully predict option price perfectly, especially because its sensitivity for the major changing on market, Black-Scholes Model still is a legitimate equation in pricing an option. The derivation of Black-Scholes has a high difficulty level because it is a stochastic partial differential equation. Black-Scholes equation has a similar principle with Path Integral, where in Black-Scholes the share's initial price is transformed to its final price. The Black-Scholes propagator function then derived by introducing a modified Lagrange based on Black-Scholes equation. Furthermore, we study the correlation between path integral analytical solution and Monte-Carlo numeric solution to find the similarity between this two methods.

  10. Magnetic flimmers: 'light in the electromagnetic darkness'.

    PubMed

    Martens, Johannes W; Koehler, Peter J; Vijselaar, Joost

    2013-03-01

    Transcranial magnetic stimulation has become an important field for both research in neuroscience and for therapy since Barker in 1985 showed that it was possible to stimulate the human motor cortex with an electromagnet. Today for instance, transcranial magnetic stimulation can be used to measure nerve conduction velocities and to create virtual lesions in the brain. The latter option creates the possibility to inactivate parts of the brain temporarily without permanent damage. In 2008, the American Food and Drugs Administration approved repetitive transcranial magnetic stimulation as a therapy for major depression under strict conditions. Repetitive transcranial magnetic stimulation has not yet been cleared for treatment of other diseases, including schizophrenia, anxiety disorders, obesity and Parkinson's disease, but results seem promising. Transcranial magnetic stimulation, however, was not invented at the end of the 20th century. The discovery of electromagnetism, the enthusiasm for electricity and electrotherapy, and the interest in Beard's concept of neurasthenia already resulted in the first electromagnetic treatments in the late 19th and early 20th century. In this article, we provide a history of electromagnetic stimulation circa 1900. From the data, we conclude that Mesmer's late 18th century ideas of 'animal magnetism' and the 19th century absence of physiological proof had a negative influence on the acceptance of this therapy during the first decades of the 20th century. Electromagnetism disappeared from neurological textbooks in the early 20th century to recur at the end of that century.

  11. An analysis of international nuclear fuel supply options

    NASA Astrophysics Data System (ADS)

    Taylor, J'tia Patrice

    As the global demand for energy grows, many nations are considering developing or increasing nuclear capacity as a viable, long-term power source. To assess the possible expansion of nuclear power and the intricate relationships---which cover the range of economics, security, and material supply and demand---between established and aspirant nuclear generating entities requires models and system analysis tools that integrate all aspects of the nuclear enterprise. Computational tools and methods now exist across diverse research areas, such as operations research and nuclear engineering, to develop such a tool. This dissertation aims to develop methodologies and employ and expand on existing sources to develop a multipurpose tool to analyze international nuclear fuel supply options. The dissertation is comprised of two distinct components: the development of the Material, Economics, and Proliferation Assessment Tool (MEPAT), and analysis of fuel cycle scenarios using the tool. Development of MEPAT is aimed for unrestricted distribution and therefore uses publicly available and open-source codes in its development when possible. MEPAT is built using the Powersim Studio platform that is widely used in systems analysis. MEPAT development is divided into three modules focusing on: material movement; nonproliferation; and economics. The material movement module tracks material quantity in each process of the fuel cycle and in each nuclear program with respect to ownership, location and composition. The material movement module builds on techniques employed by fuel cycle models such as the Verifiable Fuel Cycle Simulation (VISION) code developed at the Idaho National Laboratory under the Advanced Fuel Cycle Initiative (AFCI) for the analysis of domestic fuel cycle. Material movement parameters such as lending and reactor preference, as well as fuel cycle parameters such as process times and material factors are user-specified through a Microsoft Excel(c) data spreadsheet

  12. Solenoidal Fields for Ion Beam Transport and Focusing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, Edward P.; Leitner, Matthaeus

    In this report we calculate time-independent fields of solenoidal magnets that are suitable for ion beam transport and focusing. There are many excellent Electricity and Magnetism textbooks that present the formalism for magnetic field calculations and apply it to simple geometries [1-1], but they do not include enough relevant detail to be used for designing a charged particle transport system. This requires accurate estimates of fringe field aberrations, misaligned and tilted fields, peak fields in wire coils and iron, external fields, and more. Specialized books on magnet design, technology, and numerical computations [1-2] provide such information, and some of thatmore » is presented here. The AIP Conference Proceedings of the US Particle Accelerator Schools [1-3] contain extensive discussions of design and technology of magnets for ion beams - except for solenoids. This lack may be due to the fact that solenoids have been used primarily to transport and focus particles of relatively low momenta, e.g. electrons of less than 50 MeV and protons or H- of less than 1.0 MeV, although this situation may be changing with the commercial availability of superconducting solenoids with up to 20T bore field [1-4]. Internal reports from federal laboratories and industry treat solenoid design in detail for specific applications. The present report is intended to be a resource for the design of ion beam drivers for Inertial Fusion Energy [1-5] and Warm Dense Matter experiments [1-6], although it should also be useful for a broader range of applications. The field produced by specified currents and material magnetization can always be evaluated by solving Maxwell's equations numerically, but it is also desirable to have reasonably accurate, simple formulas for conceptual system design and fast-running beam dynamics codes, as well as for general understanding. Most of this report is devoted to such formulas, but an introduction to the Tosca{copyright} code [1-7] and some

  13. Influence of Segmentation of Ring-Shaped NdFeB Magnets with Parallel Magnetization on Cylindrical Actuators

    PubMed Central

    Eckert, Paulo Roberto; Goltz, Evandro Claiton; Filho, Aly Ferreira Flores

    2014-01-01

    This work analyses the effects of segmentation followed by parallel magnetization of ring-shaped NdFeB permanent magnets used in slotless cylindrical linear actuators. The main purpose of the work is to evaluate the effects of that segmentation on the performance of the actuator and to present a general overview of the influence of parallel magnetization by varying the number of segments and comparing the results with ideal radially magnetized rings. The analysis is first performed by modelling mathematically the radial and circumferential components of magnetization for both radial and parallel magnetizations, followed by an analysis carried out by means of the 3D finite element method. Results obtained from the models are validated by measuring radial and tangential components of magnetic flux distribution in the air gap on a prototype which employs magnet rings with eight segments each with parallel magnetization. The axial force produced by the actuator was also measured and compared with the results obtained from numerical models. Although this analysis focused on a specific topology of cylindrical actuator, the observed effects on the topology could be extended to others in which surface-mounted permanent magnets are employed, including rotating electrical machines. PMID:25051032

  14. Influence of segmentation of ring-shaped NdFeB magnets with parallel magnetization on cylindrical actuators.

    PubMed

    Eckert, Paulo Roberto; Goltz, Evandro Claiton; Flores Filho, Aly Ferreira

    2014-07-21

    This work analyses the effects of segmentation followed by parallel magnetization of ring-shaped NdFeB permanent magnets used in slotless cylindrical linear actuators. The main purpose of the work is to evaluate the effects of that segmentation on the performance of the actuator and to present a general overview of the influence of parallel magnetization by varying the number of segments and comparing the results with ideal radially magnetized rings. The analysis is first performed by modelling mathematically the radial and circumferential components of magnetization for both radial and parallel magnetizations, followed by an analysis carried out by means of the 3D finite element method. Results obtained from the models are validated by measuring radial and tangential components of magnetic flux distribution in the air gap on a prototype which employs magnet rings with eight segments each with parallel magnetization. The axial force produced by the actuator was also measured and compared with the results obtained from numerical models. Although this analysis focused on a specific topology of cylindrical actuator, the observed effects on the topology could be extended to others in which surface-mounted permanent magnets are employed, including rotating electrical machines.

  15. Interstellar Pickup Ion Acceleration in the Turbulent Magnetic Field at the Solar Wind Termination Shock Using a Focused Transport Approach

    NASA Astrophysics Data System (ADS)

    Ye, Junye; le Roux, Jakobus A.; Arthur, Aaron D.

    2016-08-01

    We study the physics of locally born interstellar pickup proton acceleration at the nearly perpendicular solar wind termination shock (SWTS) in the presence of a random magnetic field spiral angle using a focused transport model. Guided by Voyager 2 observations, the spiral angle is modeled with a q-Gaussian distribution. The spiral angle fluctuations, which are used to generate the perpendicular diffusion of pickup protons across the SWTS, play a key role in enabling efficient injection and rapid diffusive shock acceleration (DSA) when these particles follow field lines. Our simulations suggest that variation of both the shape (q-value) and the standard deviation (σ-value) of the q-Gaussian distribution significantly affect the injection speed, pitch-angle anisotropy, radial distribution, and the efficiency of the DSA of pickup protons at the SWTS. For example, increasing q and especially reducing σ enhances the DSA rate.

  16. Options for Transitional Security Capabilities for America

    DTIC Science & Technology

    2006-01-01

    the proposed parent and supporting agencies have, or are they likely to have, the resources to accomplish the mission? What would be the option’s...Agency Option The USMS is the federal law enforcement agency chosen as the parent organization for this option and could provide all the skills...need to be created to support the force. State and Metropolitan Police Option This option has two suboptions in which the parent federal agency would be

  17. 78 FR 17868 - Noncompensatory Partnership Options; Correction

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-25

    ... Noncompensatory Partnership Options; Correction AGENCY: Internal Revenue Service (IRS), Treasury. ACTION... noncompensatory options and convertible instruments issued by a partnership. The final regulations generally provide that the exercise of a noncompensatory option does not cause the recognition of immediate income...

  18. 78 FR 35559 - Noncompensatory Partnership Options; Correction

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-06-13

    ... Noncompensatory Partnership Options; Correction AGENCY: Internal Revenue Service (IRS), Treasury. ACTION... noncompensatory options and convertible instruments issued by a partnership. The final regulations generally provide that the exercise of a noncompensatory option does not cause the recognition of immediate income...

  19. Quadrupole Magnetic Sorting of Porcine Islets of Langerhans

    PubMed Central

    Shenkman, Rustin M.; Chalmers, Jeffrey J.; Hering, Bernhard J.; Kirchhof, Nicole

    2009-01-01

    Islet transplantation is emerging as a treatment option for selected patients with type 1 diabetes. Inconsistent isolation, purification, and recovery of large numbers of high-quality islets remain substantial impediments to progress in the field. Removing islets as soon as they are liberated from the pancreas during digestion and circumventing the need for density gradient purification is likely to result in substantially increased viable islet yields by minimizing exposure to proteolytic enzymes, reactive oxygen intermediates, and mechanical stress associated with centrifugation. This study capitalized on the hypervascularity of islets compared with acinar tissue to explore their preferential enrichment with magnetic beads to enable immediate separation in a magnetic field utilizing a quadrupole magnetic sorting. The results demonstrate that (1) preferential enrichment of porcine islets is achievable, but homogeneous bead distribution within the pancreas is difficult to achieve with current protocols; (2) greater than 70% of islets in the dissociated pancreatic tissue were recovered by quadrupole magnetic sorting, but their purity was low; and (3) infused islets purified by density gradients and subsequently passed through quadrupole magnetic sorting had similar potency as uninfused islets. These results demonstrate proof of concept and define the steps for implementation of this technology in pig and human islet isolation. PMID:19505179

  20. 26 CFR 1.422-2 - Incentive stock options defined.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 26 Internal Revenue 5 2010-04-01 2010-04-01 false Incentive stock options defined. 1.422-2 Section... (CONTINUED) INCOME TAXES Certain Stock Options § 1.422-2 Incentive stock options defined. (a) Incentive stock option defined—(1) In general. The term incentive stock option means an option that meets the...

  1. Sickle Cell Disease: Management Options and Challenges in Developing Countries

    PubMed Central

    Ansong, Daniel; Akoto, Alex Osei; Ocloo, Delaena; Ohene-Frempong, Kwaku

    2013-01-01

    Sickle Cell Disease (SCD) is the most common genetic disorder of haemoglobin in sub-Saharan Africa. This commentary focuses on the management options available and the challenges that health care professionals in developing countries face in caring for patients with SCD. In a developing countries like Ghana, new-born screening is now about to be implemented on a national scale. Common and important morbidities associated with SCD are vaso-occlusive episodes, infections, Acute Chest Syndrome (ACS), Stroke and hip necrosis. Approaches to the management of these morbidities are far advanced in the developed countries. The differences in setting and resource limitations in developing countries bring challenges that have a major influence in management options in developing countries. Obviously clinicians in developing countries face challenges in managing SCD patients. However understanding the disease, its progression, and instituting the appropriate preventive methods are paramount in its management. Emphasis should be placed on early counselling, new-born screening, anti-microbial prophylaxis, vaccination against infections, and training of healthcare workers, patients and caregivers. These interventions are affordable in developing countries. PMID:24363877

  2. Biopharmaceuticals from plants: a multitude of options for posttranslational modifications.

    PubMed

    Warzecha, Heribert

    2008-01-01

    In 1982 the first recombinant therapeutic, human insulin, was introduced into the market and started a new branch of pharmaceutical development, manufacture, and therapy options. To date, more than 130 recombinant protein therapeutics have been approved by the US Food and Drug Administration (FDA) and many more are being developed world wide. With the increasing number of protein therapeutics the number of potential production organisms is also expanding, and posttranslational modification of proteins has become a topic of special focus. One major difference between small-molecule drugs and protein therapeutics is that the latter are reliant on a host organism for their production and this can have a large influence on the final structure and can ultimately affect the pharmacokinetics, immunogenicity, and the function of the protein depending on the production process. Plants can be efficiently used as production systems for recombinant proteins thereby offering a variety of options for transgene targeting and modification. This review is intended to give an overview about the potential of plants to serve as a production system for therapeutic and prophylactic biopharmaceuticals with respect to posttranslational modifications.

  3. Problem Patrons: Reviewing Your Options.

    ERIC Educational Resources Information Center

    Shuman, Bruce A.

    2002-01-01

    Considers possible options for public librarians dealing with problem patrons. Highlights include considering the safety of the patrons and staff; general considerations of library security, including security guards, legal responsibility for patrons and staff safety; and working through possible options ahead of time to be more prepared. (LRW)

  4. A Smorgasbord of Assessment Options

    ERIC Educational Resources Information Center

    Bacon, Kathy A.

    2010-01-01

    The wealth of assessment options that exists offers teachers and students a "menu" of selections. Just as matching appetite needs with appropriate food selection is fundamental to a successful dining experience, matching assessment options to targeted achievement needs is crucial to an effective assessment experience. The author uses a…

  5. Bioengineering in renal transplantation: technological advances and novel options.

    PubMed

    Yeo, Wee-Song; Zhang, Yao-Chun

    2017-06-06

    End-stage kidney disease (ESKD) is one of the most prevalent diseases in the world with significant morbidity and mortality. Current modes of renal replacement therapy include dialysis and renal transplantation. Although dialysis is an acceptable mode of renal replacement therapy, it does have its shortcomings, which include poorer life expectancy compared with renal transplantation, risk of infections and vascular thrombosis, lack of vascular access and absence of biosynthetic functions of the kidney. Renal transplantation, in contrast, is the preferred option of renal replacement therapy, with improved morbidity and mortality rates and quality of life, compared with dialysis. Renal transplantation, however, may not be available to all patients with ESKD. Some of the key factors limiting the availability and efficiency of renal transplantation include shortage of donor organs and the constant risk of rejection with complications associated with over-immunosuppression respectively. This review focuses chiefly on the potential roles of bioengineering in overcoming limitations in renal transplantation via the development of cell-based bioartificial dialysis devices as bridging options before renal transplantation, and the development of new sources of organs utilizing cell and organ engineering.

  6. 48 CFR 517.207 - Exercise of options.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 48 Federal Acquisition Regulations System 4 2012-10-01 2012-10-01 false Exercise of options. 517.207 Section 517.207 Federal Acquisition Regulations System GENERAL SERVICES ADMINISTRATION CONTRACTING METHODS AND CONTRACT TYPES SPECIAL CONTRACTING METHODS Options 517.207 Exercise of options. Before...

  7. 48 CFR 517.207 - Exercise of options.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 48 Federal Acquisition Regulations System 4 2013-10-01 2013-10-01 false Exercise of options. 517.207 Section 517.207 Federal Acquisition Regulations System GENERAL SERVICES ADMINISTRATION CONTRACTING METHODS AND CONTRACT TYPES SPECIAL CONTRACTING METHODS Options 517.207 Exercise of options. Before...

  8. 48 CFR 517.207 - Exercise of options.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 48 Federal Acquisition Regulations System 4 2014-10-01 2014-10-01 false Exercise of options. 517.207 Section 517.207 Federal Acquisition Regulations System GENERAL SERVICES ADMINISTRATION CONTRACTING METHODS AND CONTRACT TYPES SPECIAL CONTRACTING METHODS Options 517.207 Exercise of options. Before...

  9. 48 CFR 517.207 - Exercise of options.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 48 Federal Acquisition Regulations System 4 2011-10-01 2011-10-01 false Exercise of options. 517.207 Section 517.207 Federal Acquisition Regulations System GENERAL SERVICES ADMINISTRATION CONTRACTING METHODS AND CONTRACT TYPES SPECIAL CONTRACTING METHODS Options 517.207 Exercise of options. Before...

  10. Efficacy of sub-threshold focused ultrasound irradiation against pancreatic cancer xenografts evaluated using magnetic resonance imaging

    PubMed Central

    Chen, Yini; Gao, Yihui; Wu, Lei

    2017-01-01

    We investigated the efficacy and optimal period for using magnetic resonance imaging (MRI) to detect effects of sub-threshold focused ultrasound (FUS) irradiation. Nude mice bearing pancreatic cancer xenografts were subjected to MRI and pathology examnation before, and 24 h, 48 h, 2 weeks after irradiation, which were used to evaluate therapeutic effects of FUS. Tumor volumes were lower post-treatment than control group (P < 0.05). The T1WI turbo spin echo (T1WI-TSE) sequence was similar signal before and after treatment. On T1 enhanced scanning sequence (T1WI-SPIR) imaging, ablation lesions appeared as patchy areas of low signal after 24 h and 48 h. After 2 weeks, the ablation lesions contained low signal areas with clear borders. Hematoxylin and eosin (HE) staining revealed small vessels at ablation lesions with no obvious boundary between cell injury areas and normal tumor cells areas in early-stage, while revealed obvious boundaries 2 weeks post-treatment. Terminal deoxynucleotidyl transferase-modified, dUTP nick-end labeling (TUNEL) staining showed cell apoptosis in early-stage, and revealed reduced apoptotic cells and increased necrotic cell areas 2 weeks later. These findings indicate sub-threshold FUS induces pancreatic cancer cell apoptosis and inhibits tumor growth. Contrast-enhanced MRI delineated the ablation lesions better 2 weeks post-treatment than early stage. PMID:29113316

  11. Magnetic-mediated hyperthermia for cancer treatment: Research progress and clinical trials

    NASA Astrophysics Data System (ADS)

    Zhao, Ling-Yun; Liu, Jia-Yi; Ouyang, Wei-Wei; Li, Dan-Ye; Li, Li; Li, Li-Ya; Tang, Jin-Tian

    2013-10-01

    Research progress and frontiers of magnetic-mediated hyperthermia (MMH) are presented, along with clinical trials in Germany, the US, Japan, and China. Special attention is focused on MMH mediated by magnetic nanoparticles, and multifunctional magnetic devices for cancer multimodality treatment are also introduced.

  12. Ghrelin, MicroRNAs, and Critical Limb Ischemia: Hungering for a Novel Treatment Option.

    PubMed

    Neale, Joshua P H; Pearson, James T; Katare, Rajesh; Schwenke, Daryl O

    2017-01-01

    Critical limb ischemia (CLI) is the most severe manifestation of peripheral artery disease. It is characterized by chronic pain at rest, skin ulcerations, and gangrene tissue loss. CLI is a highly morbid condition, resulting in a severely diminished quality of life and a significant risk of mortality. The primary goal of therapy for CLI is to restore blood flow to the affected limb, which is only possible by surgery, but is inadvisable in up to 50% of patients. This subset of patients who are not candidates for revascularisation are referred to as "no-option" patients and are the focus of investigation for novel therapeutic strategies. Angiogenesis, arteriogenesis and vasculogenesis are the processes whereby new blood vessel networks form from the pre-existing vasculature and primordial cells, respectively. In therapeutic angiogenesis, exogenous stimulants are administered to promote angiogenesis and augment limb perfusion, offering a potential treatment option for "no option" patients. However, to date, very few clinical trials of therapeutic angiogenesis in patients with CLI have reported clinically significant results, and it remains a major challenge. Ghrelin, a 28-amino acid peptide, is emerging as a potential novel therapeutic for CLI. In pre-clinical models, exogenous ghrelin has been shown to induce therapeutic angiogenesis, promote muscle regeneration, and reduce oxidative stress via the modulation of microRNAs (miRs). miRs are endogenous, small, non-coding ribonucleic acids of ~20-22 nucleotides which regulate gene expression at the post-transcriptional level by either translational inhibition or by messenger ribonucleic acid cleavage. This review focuses on the mounting evidence for the use of ghrelin as a novel therapeutic for CLI, and highlights the miRs which orchestrate these physiological events.

  13. Magnetically adjustable intraocular lens.

    PubMed

    Matthews, Michael Wayne; Eggleston, Harry Conrad; Pekarek, Steven D; Hilmas, Greg Eugene

    2003-11-01

    To provide a noninvasive, magnetic adjustment mechanism to the repeatedly and reversibly adjustable, variable-focus intraocular lens (IOL). University of Missouri-Rolla, Rolla, and Eggleston Adjustable Lens, St. Louis, Missouri, USA. Mechanically adjustable IOLs have been fabricated and tested. Samarium and cobalt rare-earth magnets have been incorporated into the poly(methyl methacrylate) (PMMA) optic of these adjustable lenses. The stability of samarium and cobalt in the PMMA matrix was examined with leaching studies. Operational force testing of the magnetic optics with emphasis on the rotational forces of adjustment was done. Prototype optics incorporating rare-earth magnetic inserts were consistently produced. After 32 days in solution, samarium and cobalt concentration reached a maximum of 5 ppm. Operational force measurements indicate that successful adjustments of this lens can be made using external magnetic fields with rotational torques in excess of 0.6 ounce inch produced. Actual lenses were remotely adjusted using magnetic fields. The magnetically adjustable version of this IOL is a viable and promising means of handling the common issues of postoperative refractive errors without the requirement of additional surgery. The repeatedly adjustable mechanism of this lens also holds promise for the developing eyes of pediatric patients and the changing needs of all patients.

  14. Vibration measurements and analyses for a magnet superconductor levitated system

    NASA Astrophysics Data System (ADS)

    Wen, Zheng; Liu, Yu; Yang, Wenjiang; Qiu, Ming

    2007-12-01

    Magnetic levitation technology, having the characteristics of low cost and high quality, has been considered a preferable option for the next generation of launcher systems. A world-wide research design on the conceptual level has been carried out on the highly reusable space transportation systems by applying magnetic levitation to the launch assistance. Recently, a research plan has been implemented in our laboratory by constructing a scale-model suspension system with high temperature superconductor (HTS henceforth) bulks over a 7 m Nd-Fe-B permanent-magnet (PM henceforth) track for the launch assistance. An experimental platform was built to investigate the dynamic responses of the PM-HTS interaction at different field-cooled positions. The critical frequencies and amplitudes which lead to the instability of levitation drift were investigated. The stiffness and the vibration damping were also discussed at the zero-field-cooled position.

  15. Design Evolution Study - Aging Options

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    P. McDaniel

    The purpose of this study is to identify options and issues for aging commercial spent nuclear fuel received for disposal at the Yucca Mountain Mined Geologic Repository. Some early shipments of commercial spent nuclear fuel to the repository may be received with high-heat-output (younger) fuel assemblies that will need to be managed to meet thermal goals for emplacement. The capability to age as much as 40,000 metric tons of heavy metal of commercial spent nuclear he1 would provide more flexibility in the design to manage this younger fuel and to decouple waste receipt and waste emplacement. The following potential agingmore » location options are evaluated: (1) Surface aging at four locations near the North Portal; (2) Subsurface aging in the permanent emplacement drifts; and (3) Subsurface aging in a new subsurface area. The following aging container options are evaluated: (1) Complete Waste Package; (2) Stainless Steel inner liner of the waste package; (3) Dual Purpose Canisters; (4) Multi-Purpose Canisters; and (5) New disposable canister for uncanistered commercial spent nuclear fuel. Each option is compared to a ''Base Case,'' which is the expected normal waste packaging process without aging. A Value Engineering approach is used to score each option against nine technical criteria and rank the options. Open issues with each of the options and suggested future actions are also presented. Costs for aging containers and aging locations are evaluated separately. Capital costs are developed for direct costs and distributable field costs. To the extent practical, unit costs are presented. Indirect costs, operating costs, and total system life cycle costs will be evaluated outside of this study. Three recommendations for aging commercial spent nuclear fuel--subsurface, surface, and combined surface and subsurface are presented for further review in the overall design re-evaluation effort. Options that were evaluated but not recommended are: subsurface aging in a

  16. Exploration Architecture Options - ECLSS, EVA, TCS Implications

    NASA Technical Reports Server (NTRS)

    Chambliss, Joe; Henninger, Don; Lawrence, Carl

    2010-01-01

    Many options for exploration of space have been identified and evaluated since the Vision for Space Exploration (VSE) was announced in 2004. Lunar architectures have been identified and addressed in the Lunar Surface Systems team to establish options for how to get to and then inhabit and explore the moon. The Augustine Commission evaluated human space flight for the Obama administration and identified many options for how to conduct human spaceflight in the future. This paper will evaluate the options for exploration of space for the implications of architectures on the Environmental Control and Life Support (ECLSS), ExtraVehicular Activity (EVA) and Thermal Control System (TCS) Systems. The advantages and disadvantages of each architecture and options are presented.

  17. 17 CFR 33.3 - Unlawful commodity option transactions.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 17 Commodity and Securities Exchanges 1 2010-04-01 2010-04-01 false Unlawful commodity option... REGULATION OF DOMESTIC EXCHANGE-TRADED COMMODITY OPTION TRANSACTIONS § 33.3 Unlawful commodity option... of, or maintain a position in, any commodity option transaction subject to the provisions of this...

  18. Current Treatment Options for Bilateral Vocal Fold Paralysis: A State-of-the-Art Review

    PubMed Central

    Li, Yike; Garrett, Gaelyn; Zealear, David

    2017-01-01

    Vocal fold paralysis (VFP) refers to neurological causes of reduced or absent movement of one or both vocal folds. Bilateral VFP (BVFP) is characterized by inspiratory dyspnea due to narrowing of the airway at the glottic level with both vocal folds assuming a paramedian position. The primary objective of intervention for BVFP is to relieve patients’ dyspnea. Common clinical options for management include tracheostomy, arytenoidectomy and cordotomy. Other options that have been used with varying success include reinnervation techniques and botulinum toxin (Botox) injections into the vocal fold adductors. More recently, research has focused on neuromodulation, laryngeal pacing, gene therapy, and stem cell therapy. These newer approaches have the potential advantage of avoiding damage to the voicing mechanism of the larynx with an added goal of restoring some physiologic movement of the affected vocal folds. However, clinical data are scarce for these new treatment options (i.e., reinnervation and pacing), so more investigative work is needed. These areas of research are expected to provide dramatic improvements in the treatment of BVFP. PMID:28669149

  19. Crew Transfer Options for Servicing of Geostationary Satellites

    NASA Technical Reports Server (NTRS)

    Cerro, Jeffrey A.

    2012-01-01

    In 2011, NASA and DARPA undertook a study to examine capabilities and system architecture options which could be used to provide manned servicing of satellites in Geostationary Earth Orbit (GEO). The study focused on understanding the generic nature of the problem and examining technology requirements, it was not for the purpose of proposing or justifying particular solutions. A portion of this study focused on assessing possible capabilities to efficiently transfer crew between Earth, Low Earth Orbit (LEO), and GEO satellite servicing locations. This report summarizes the crew transfer aspects of manned GEO satellite servicing. Direct placement of crew via capsule vehicles was compared to concepts of operation which divided crew transfer into multiple legs, first between earth and LEO and second between LEO and GEO. In space maneuvering via purely propulsive means was compared to in-space maneuvering which utilized aerobraking maneuvers for return to LEO from GEO. LEO waypoint locations such as equatorial, Kennedy Space Center, and International Space Station inclinations were compared. A discussion of operational concepts is followed by a discussion of appropriate areas for technology development.

  20. Identity Options in Russian Textbooks

    ERIC Educational Resources Information Center

    Shardakova, Marya; Pavlenko, Aneta

    2004-01-01

    This article introduces a new analytical approach to the study of identity options offered in foreign and second language textbooks. This approach, grounded in poststructuralist theory and critical discourse analysis, is applied to 2 popular beginning Russian textbooks. Two sets of identity options are examined in the study: imagined learners…

  1. Sound therapy for tinnitus management: practicable options.

    PubMed

    Hoare, Derek J; Searchfield, Grant D; El Refaie, Amr; Henry, James A

    2014-01-01

    The authors reviewed practicable options of sound therapy for tinnitus, the evidence base for each option, and the implications of each option for the patient and for clinical practice. To provide a general guide to selecting sound therapy options in clinical practice. Practicable sound therapy options. Where available, peer-reviewed empirical studies, conference proceedings, and review studies were examined. Material relevant to the purpose was summarized in a narrative. The number of peer-reviewed publications pertaining to each sound therapy option reviewed varied significantly (from none to over 10). Overall there is currently insufficient evidence to support or refute the routine use of individual sound therapy options. It is likely, however, that sound therapy combined with education and counseling is generally helpful to patients. Clinicians need to be guided by the patient's point of care, patient motivation and expectations of sound therapy, and the acceptability of the intervention both in terms of the sound stimuli they are to use and whether they are willing to use sound extensively or intermittently. Clinicians should also clarify to patients the role sound therapy is expected to play in the management plan. American Academy of Audiology.

  2. 24 CFR 3285.503 - Optional appliances.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... URBAN DEVELOPMENT MODEL MANUFACTURED HOME INSTALLATION STANDARDS Optional Features § 3285.503 Optional... Manufactured Home Construction and Safety Standards in this chapter. (3) When the vent exhausts through the...

  3. 24 CFR 3285.503 - Optional appliances.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... URBAN DEVELOPMENT MODEL MANUFACTURED HOME INSTALLATION STANDARDS Optional Features § 3285.503 Optional... Manufactured Home Construction and Safety Standards in this chapter. (3) When the vent exhausts through the...

  4. 24 CFR 3285.503 - Optional appliances.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... URBAN DEVELOPMENT MODEL MANUFACTURED HOME INSTALLATION STANDARDS Optional Features § 3285.503 Optional... Manufactured Home Construction and Safety Standards in this chapter. (3) When the vent exhausts through the...

  5. Numerical Algorithm for Delta of Asian Option

    PubMed Central

    Zhang, Boxiang; Yu, Yang; Wang, Weiguo

    2015-01-01

    We study the numerical solution of the Greeks of Asian options. In particular, we derive a close form solution of Δ of Asian geometric option and use this analytical form as a control to numerically calculate Δ of Asian arithmetic option, which is known to have no explicit close form solution. We implement our proposed numerical method and compare the standard error with other classical variance reduction methods. Our method provides an efficient solution to the hedging strategy with Asian options. PMID:26266271

  6. Pursuing ethical coherence in the prevention of vertical transmission of HIV: justice and injustice in Option B.

    PubMed

    Hodson, Nathan; Bewley, Susan

    2017-07-01

    Improved prevention of vertical transmission of HIV is an essential part of the global response to HIV. The Option B+ strategy took the extraordinary step of treating many non-pregnant women living with HIV (those with CD4 cell counts >350 cells/mm 3 ) in the absence of evidence that they themselves would benefit from ART. This example of so-called AIDS exceptionalism reflects an understanding that the global response to HIV demands a different set of morals. This philosophical article explores a retrospective analysis of the ethical arguments made in support of Option B+ incorporating utilitarian, feminist and equity-based frameworks. A number of inconsistencies were found in the arguments made for the introduction of Option B+ well before results were available from the START and TEMPRANO trials. Although some people think 'the ends justify the means', we conclude that erroneous justifications were initially given in support of Option B+. We identify tensions that remain in light of these results and argue that future strategies would benefit from a community-focused, human rights-based approach.

  7. 17 CFR 32.3 - Unlawful commodity option transactions.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 17 Commodity and Securities Exchanges 1 2010-04-01 2010-04-01 false Unlawful commodity option... REGULATION OF COMMODITY OPTION TRANSACTIONS § 32.3 Unlawful commodity option transactions. (a) On and after... extend credit in lieu thereof) from an option customer as payment of the purchase price in connection...

  8. Magnetic Fields and Flows in Open Magnetic Structures

    NASA Technical Reports Server (NTRS)

    Jones, Harrlson P.

    2004-01-01

    Open magnetic structures connect the solar surface to the heliosphere and are thus of great interest in solar-terrestrial physics. This talk is primarily an observational review of what is known about magnetic fields and particularly flows in such regions with special focus on coronal holes and origins of the fast solar wind. First evidence of the connection between these two features was seen in correlations of Skylab data with in situ measurements of the solar wind soon after the discovery of coronal holes, which are now known to emanate from unipolar magnetic regions at the photosphere. Subsequently many observations of have been made, ranging from oscillations in the underlying photosphere and chromosphere, to possible beginnings of the solar wind as observed by Doppler shifts in high chromospheric and transition-region lines, to coronagraphic time-lapse studies of outward-moving blobs of material which perhaps trace elements of solar-wind plasma. Some of the many unresolved and controversial issues regarding details of these observations and their association with the solar wind will be discussed.

  9. Variable Permanent Magnet Quadrupole

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mihara, T.; Iwashita, Y.; /Kyoto U.

    A permanent magnet quadrupole (PMQ) is one of the candidates for the final focus lens in a linear collider. An over 120 T/m strong variable permanent magnet quadrupole is achieved by the introduction of saturated iron and a 'double ring structure'. A fabricated PMQ achieved 24 T integrated gradient with 20 mm bore diameter, 100 mm magnet diameter and 20 cm pole length. The strength of the PMQ is adjustable in 1.4 T steps, due to its 'double ring structure': the PMQ is split into two nested rings; the outer ring is sliced along the beam line into four partsmore » and is rotated to change the strength. This paper describes the variable PMQ from fabrication to recent adjustments.« less

  10. 40 CFR 35.6345 - Equipment disposal options.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 1 2010-07-01 2010-07-01 false Equipment disposal options. 35.6345 Section 35.6345 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY GRANTS AND OTHER FEDERAL... options. The following disposal options are available: (a) Use the equipment on another CERCLA project and...

  11. 48 CFR 1517.207 - Exercise of options.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 48 Federal Acquisition Regulations System 6 2011-10-01 2011-10-01 false Exercise of options. 1517... CONTRACTING METHODS AND CONTRACT TYPES SPECIAL CONTRACTING METHODS Options 1517.207 Exercise of options. (a... periods shall require that a preliminary written notice of the Government's intention to exercise the...

  12. 48 CFR 1517.207 - Exercise of options.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 48 Federal Acquisition Regulations System 6 2012-10-01 2012-10-01 false Exercise of options. 1517... CONTRACTING METHODS AND CONTRACT TYPES SPECIAL CONTRACTING METHODS Options 1517.207 Exercise of options. (a... periods shall require that a preliminary written notice of the Government's intention to exercise the...

  13. 48 CFR 1517.207 - Exercise of options.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 48 Federal Acquisition Regulations System 6 2014-10-01 2014-10-01 false Exercise of options. 1517... CONTRACTING METHODS AND CONTRACT TYPES SPECIAL CONTRACTING METHODS Options 1517.207 Exercise of options. (a... periods shall require that a preliminary written notice of the Government's intention to exercise the...

  14. 48 CFR 1517.207 - Exercise of options.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 48 Federal Acquisition Regulations System 6 2013-10-01 2013-10-01 false Exercise of options. 1517... CONTRACTING METHODS AND CONTRACT TYPES SPECIAL CONTRACTING METHODS Options 1517.207 Exercise of options. (a... periods shall require that a preliminary written notice of the Government's intention to exercise the...

  15. Mission Options for an Electric Propulsion Demonstration Flight Test

    NASA Technical Reports Server (NTRS)

    Garner, Charles

    1989-01-01

    Several mission options are discussed for an electric propulsion space test which provides operational and performance data for ion and arcjet propulsion systems and testing of APSA arrays and a super power system. The results of these top-level studies are considered preliminary. Ion propulsion system design and architecture for the purposes of performing orbit raising missions for payloads in the range of 2400 to 2700 kg are described. Focus was placed on a design which can be characterized by simplicity, reliability, and performance. Systems of this design are suitable for an electric propulsion precursor flight which would provide proof of principle data necessary for more ambitious and complex missions.

  16. Treatment Options for the Cardinal Symptoms of Disruptive Mood Dysregulation Disorder

    PubMed Central

    Tourian, Leon; LeBoeuf, Amélie; Breton, Jean-Jacques; Cohen, David; Gignac, Martin; Labelle, Réal; Guile, Jean-Marc; Renaud, Johanne

    2015-01-01

    Objective: DSM-5 has added a new developmentally appropriate child and adolescent mood disorder subtype called disruptive mood dysregulation disorder (DMDD). The core features of DMDD are temper outbursts (manifested by either verbal rages and/or physical aggression) and unrelenting irritability or anger. Currently, the literature is lacking a thorough review of the possible treatment options for the cardinal symptoms constituting DMDD. The objective of this article is to provide a thorough review of peer-reviewed studies on the subject of pharmacological treatment options for children and adolescents with the cardinal symptoms of DMDD. Methods: Relevant articles for this study were obtained through Pubmed, Medline, PsychINFO and PsychINDEXplus using the key words: “adolescents,” “children,” “paediatric,” “youth,” “irritability,” “temper outbursts,” “aggression,” “rage,” “disruptive behaviour,” “treatment,” “dysphoria,” “autism,” “mental retardation/intellectual disability,” “impulsivity,” “ADHD,” “oppositional defiant disorder,” and “conduct disorder.” A total of 823 studies were generated; only English studies focusing on pharmacological treatment were retained. Results: Currently there are no established guidelines or thorough reviews summarizing the treatment of DMDD. Pharmacotherapeutic treatment options of both aggression and chronic irritability include: antidepressants/selective norepinephrine reuptake inhibitors, mood stabilizers, psychostimulants, antipsychotics, and alpha-2 agonists. Conclusion: Treatment options of severe, persistent irritability in youth are numerous, and a consensual treatment algorithm has not yet emerged from the literature. Further studies and clinical trials are warranted to determine efficacious and safe treatment modalities. PMID:26336379

  17. Factors associated with retention in Option B+ in Malawi: a case control study.

    PubMed

    Hoffman, Risa M; Phiri, Khumbo; Parent, Julie; Grotts, Jonathan; Elashoff, David; Kawale, Paul; Yeatman, Sara; Currier, Judith S; Schooley, Alan

    2017-04-27

    There are limited data on factors associated with retention in Option B+. We sought to explore the characteristics of women retained in Option B+ in Malawi, with a focus on the role of HIV disclosure, awareness of partner HIV status, and knowledge around the importance of Option B+ for maternal-child health. Methods We performed a case-control study of HIV-infected women in Malawi initiated on antiretroviral therapy (ART) under Option B+. Cases were enrolled if they met criteria for default from Option B+ (out of ART for >60 days), and controls were enrolled in approximately 3:1 ratio if they were retained in care for at least 12 months. We surveyed socio-demographic characteristics, HIV disclosure and awareness of partner HIV status, self-report about receiving pre-ART education, and knowledge of Option B+. Univariate logistic regression was performed to determine factors associated with retention. Multivariate logistic regression model was used to evaluate the relationship between HIV disclosure, Option B+ knowledge, and retention after adjusting for age, schooling, and travel time to clinic. We enrolled 50 cases and 153 controls. Median age was 30 years (interquartile range (IQR) 25-34), and the majority (82%) initiated ART during pregnancy at a median gestational age of 24 weeks (IQR 16-28). Ninety-one per cent of the cases (39/43) who started ART during pregnancy defaulted by three months postpartum. HIV disclosure to the primary sex partner was more common among women retained in care (100% versus 78%, p  < 0.001). Odds of retention were significantly higher among women with: age >25 years (odds ratio (OR) 2.44), completion of primary school (OR 3.06), awareness of partner HIV status (OR 5.20), pre-ART education (OR 6.17), higher number of correct answers to Option B+ knowledge questions (OR 1.82), and support while taking ART (OR 3.65). Pre-ART education and knowledge were significantly correlated ( r  = 0.43, p  < 0.001). In multivariate analysis

  18. Factors associated with retention in Option B+ in Malawi: a case control study

    PubMed Central

    Hoffman, Risa M; Phiri, Khumbo; Parent, Julie; Grotts, Jonathan; Elashoff, David; Kawale, Paul; Yeatman, Sara; Currier, Judith S; Schooley, Alan

    2017-01-01

    Abstract Introduction: There are limited data on factors associated with retention in Option B+. We sought to explore the characteristics of women retained in Option B+ in Malawi, with a focus on the role of HIV disclosure, awareness of partner HIV status, and knowledge around the importance of Option B+ for maternal–child health. Methods: We performed a case-control study of HIV-infected women in Malawi initiated on antiretroviral therapy (ART) under Option B+. Cases were enrolled if they met criteria for default from Option B+ (out of ART for >60 days), and controls were enrolled in approximately 3:1 ratio if they were retained in care for at least 12 months. We surveyed socio-demographic characteristics, HIV disclosure and awareness of partner HIV status, self-report about receiving pre-ART education, and knowledge of Option B+. Univariate logistic regression was performed to determine factors associated with retention. Multivariate logistic regression model was used to evaluate the relationship between HIV disclosure, Option B+ knowledge, and retention after adjusting for age, schooling, and travel time to clinic. Results: We enrolled 50 cases and 153 controls. Median age was 30 years (interquartile range (IQR) 25–34), and the majority (82%) initiated ART during pregnancy at a median gestational age of 24 weeks (IQR 16–28). Ninety-one per cent of the cases (39/43) who started ART during pregnancy defaulted by three months postpartum. HIV disclosure to the primary sex partner was more common among women retained in care (100% versus 78%, p < 0.001). Odds of retention were significantly higher among women with: age >25 years (odds ratio (OR) 2.44), completion of primary school (OR 3.06), awareness of partner HIV status (OR 5.20), pre-ART education (OR 6.17), higher number of correct answers to Option B+ knowledge questions (OR 1.82), and support while taking ART (OR 3.65). Pre-ART education and knowledge were significantly correlated (r = 0.43, p

  19. Biosensing Using Magnetic Particle Detection Techniques

    PubMed Central

    Chen, Yi-Ting; Kolhatkar, Arati G.; Zenasni, Oussama; Xu, Shoujun

    2017-01-01

    Magnetic particles are widely used as signal labels in a variety of biological sensing applications, such as molecular detection and related strategies that rely on ligand-receptor binding. In this review, we explore the fundamental concepts involved in designing magnetic particles for biosensing applications and the techniques used to detect them. First, we briefly describe the magnetic properties that are important for bio-sensing applications and highlight the associated key parameters (such as the starting materials, size, functionalization methods, and bio-conjugation strategies). Subsequently, we focus on magnetic sensing applications that utilize several types of magnetic detection techniques: spintronic sensors, nuclear magnetic resonance (NMR) sensors, superconducting quantum interference devices (SQUIDs), sensors based on the atomic magnetometer (AM), and others. From the studies reported, we note that the size of the MPs is one of the most important factors in choosing a sensing technique. PMID:28994727

  20. Copper tellurium oxides - A playground for magnetism

    NASA Astrophysics Data System (ADS)

    Norman, M. R.

    2018-04-01

    A variety of copper tellurium oxide minerals are known, and many of them exhibit either unusual forms of magnetism, or potentially novel spin liquid behavior. Here, I review a number of the more interesting materials with a focus on their crystalline symmetry and, if known, the nature of their magnetism. Many of these exist (so far) in mineral form only, and most have yet to have their magnetic properties studied. This means a largely unexplored space of materials awaits our exploration.

  1. Copper Tellurium Oxides - A Playground for Magnetism.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Norman, M. R.

    A variety of copper tellurium oxide minerals are known, and many of them exhibit either unusual forms of magnetism, or potentially novel spin liquid behavior. Here, I review a number of the more interesting materials with a focus on their crystalline symmetry and, if known, the nature of their magnetism. Many of these exist (so far) in mineral form only, and most have yet to have their magnetic properties studied. This means a largely unexplored space of materials awaits our exploration.

  2. 7 CFR 457.172 - Coverage Enhancement Option.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 6 2010-01-01 2010-01-01 false Coverage Enhancement Option. 457.172 Section 457.172..., DEPARTMENT OF AGRICULTURE COMMON CROP INSURANCE REGULATIONS § 457.172 Coverage Enhancement Option. The Coverage Enhancement Option for the 2009 and succeeding crop years are as follows: FCIC policies: United...

  3. 48 CFR 217.207 - Exercise of options.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 48 Federal Acquisition Regulations System 3 2012-10-01 2012-10-01 false Exercise of options. 217.207 Section 217.207 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM... Exercise of options. (c) In addition to the requirements at FAR 17.207(c), exercise an option only after...

  4. 48 CFR 217.207 - Exercise of options.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 48 Federal Acquisition Regulations System 3 2011-10-01 2011-10-01 false Exercise of options. 217.207 Section 217.207 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM... Exercise of options. (c) In addition to the requirements at FAR 17.207(c), exercise an option only after...

  5. 48 CFR 217.207 - Exercise of options.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 48 Federal Acquisition Regulations System 3 2014-10-01 2014-10-01 false Exercise of options. 217.207 Section 217.207 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM... Exercise of options. (c) In addition to the requirements at FAR 17.207(c), exercise an option only after...

  6. 48 CFR 217.207 - Exercise of options.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 48 Federal Acquisition Regulations System 3 2013-10-01 2013-10-01 false Exercise of options. 217.207 Section 217.207 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM... Exercise of options. (c) In addition to the requirements at FAR 17.207(c), exercise an option only after...

  7. Is an Apple Magnetic: Magnetic Response of Everyday Materials Supporting Views About the Nature of Science

    NASA Astrophysics Data System (ADS)

    Laumann, Daniel

    2017-03-01

    Magnetism and its various applications are essential for our daily life and for many technological developments. The term magnetism is almost always used as a synonym for ferromagnetism. However, the magnetic properties of the elements of the periodic table indicate that the vast majority of elements are not ferromagnetic, but rather, diamagnetic or paramagnetic. Typically, only ferromagnetism is discussed in classrooms, which can create a distorted picture. This article supplies the further development of an experiment demonstrating the dia- and paramagnetic properties with an electronic balance and a neodymium magnet. It focuses on an investigation of ordinary materials that occur in pupils' everyday environment. The experiment is applicable both for a quantitative measurement of the magnetic (volume) susceptibility χV and can serve as a phenomenological approach to dia- and paramagnetism. Moreover, it encourages a discussion about typical beliefs regarding the nature of science, comparing the behavior of common objects in weak and in strong magnetic fields.

  8. Magnetic and Optical Properties of Submicron-Size Hollow Spheres

    PubMed Central

    Ye, Quan-Lin; Yoshikawa, Hirofumi; Awaga, Kunio

    2010-01-01

    Magnetic hollow spheres with a controlled diameter and shell thickness have emerged as an important class of magnetic nanomaterials. The confined hollow geometry and pronouncedly curved surfaces induce unique physical properties different from those of flat thin films and solid counterparts. In this paper, we focus on recent progress on submicron-size spherical hollow magnets (e.g., cobalt- and iron-based materials), and discuss the effects of the hollow shape and the submicron size on magnetic and optical properties.

  9. 48 CFR 552.217-70 - Evaluation of Options.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 4 2010-10-01 2010-10-01 false Evaluation of Options. 552... Evaluation of Options. As prescribed in 517.208(a), insert the following provision: Evaluation of Options... period price. When option year pricing is based on a formula (e.g., changes in the Producer Price Index...

  10. 5 CFR 870.704 - Amount of Option A.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 5 Administrative Personnel 2 2010-01-01 2010-01-01 false Amount of Option A. 870.704 Section 870... of Option A. (a) The amount of Option A coverage an annuitant or compensationer can continue is $10,000. (b) An annuitant's or compensationer's Option A coverage reduces by 2 percent of the original...

  11. 24 CFR 206.26 - Change in payment option.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 24 Housing and Urban Development 2 2010-04-01 2010-04-01 false Change in payment option. 206.26... in payment option. (a) General. The payment option may be changed as provided in this section. (b... credit payment option. Until the repairs are completed, the mortgagee shall make no line of credit...

  12. Eco-efficiency improvements in industrial water-service systems: assessing options with stakeholders.

    PubMed

    Levidow, Les; Lindgaard-Jørgensen, Palle; Nilsson, Asa; Skenhall, Sara Alongi; Assimacopoulos, Dionysis

    2014-01-01

    The well-known eco-efficiency concept helps to assess the economic value and resource burdens of potential improvements by comparison with the baseline situation. But eco-efficiency assessments have generally focused on a specific site, while neglecting wider effects, for example, through interactions between water users and wastewater treatment (WWT) providers. To address the methodological gap, the EcoWater project has developed a method and online tools for meso-level analysis of the entire water-service value chain. This study investigated improvement options in two large manufacturing companies which have significant potential for eco-efficiency gains. They have been considering investment in extra processes which can lower resource burdens from inputs and wastewater, as well as internalising WWT processes. In developing its methodology, the EcoWater project obtained the necessary information from many agents, involved them in the meso-level assessment and facilitated their discussion on alternative options. Prior discussions with stakeholders stimulated their attendance at a workshop to discuss a comparative eco-efficiency assessment for whole-system improvement. Stakeholders expressed interest in jointly extending the EcoWater method to more options and in discussing investment strategies. In such ways, optimal solutions will depend on stakeholders overcoming fragmentation by sharing responsibility and knowledge.

  13. Design Options for Multimodal Web Applications

    NASA Astrophysics Data System (ADS)

    Stanciulescu, Adrian; Vanderdonckt, Jean

    The capabilities of multimodal applications running on the web are well de-lineated since they are mainly constrained by what their underlying standard mark up language offers, as opposed to hand-made multimodal applications. As the experience in developing such multimodal web applications is growing, the need arises to identify and define major design options of such application to pave the way to a structured development life cycle. This paper provides a design space of independent design options for multimodal web applications based on three types of modalities: graphical, vocal, tactile, and combined. On the one hand, these design options may provide designers with some explicit guidance on what to decide or not for their future user interface, while exploring various design alternatives. On the other hand, these design options have been implemented as graph transformations per-formed on a user interface model represented as a graph. Thanks to a transformation engine, it allows designers to play with the different values of each design option, to preview the results of the transformation, and to obtain the corresponding code on-demand

  14. Disturbance in the Tropical Ionosphere and Earth Magnetic Field Mensured on the Magnetic Equator Caused by Magnetic Storms

    NASA Astrophysics Data System (ADS)

    Almeida, Pedro; Sobral, José; Resende, Laysa; Marcos Denardini, Clezio; Carlotto Aveiro, Henrique

    The focus of the present work is to monitor the disturbances in the equatorial F region caused by magnetic storms and comparatively to observe possible effects caused by the storms in the earth magnetics field measured on the ground, aiming to establish the events time occurrence order. The motivation for this work is due to the diversity of phenomena of scientific interest, which are observed in this region and also are capable to disturbance the transionospheric communication. The monitoring on the ionospheric plasma variation in the F region during and after the magnetics storms can generate indications of magnetosphere - ionosphere coupling effects. For this study we have used F region parameters measured by digital sounder installed at the Observatório Espacial de São Lú (2.33° S; 44.20° W; -0.5° DIP): foF2 (critical frequency o a ıs of F layer), hmF2 (real height of electronic density F layer peak) and h'F (minimum virtual height of F layer). For monitoring the disturbance in the magnetic field we have studied the H- and Z-component of the Earth magnetic field measured by magnetometers installed in the same site. The results are presented and discussed.

  15. Early Childhood Programs and Policy in the Northwest and Hawaii: Early Childhood Policy Issues and Options.

    ERIC Educational Resources Information Center

    Conklin, Nancy Faires; And Others

    Discussed are early childhood policy issues and options for Alaska, Hawaii, Idaho, Montana, Oregon, and Washington. Section I explores federal and state directions in terms of levels of policy making, federal and state issues, and interested parties. Section II focuses on policy issues in its discussions of the political climate, long-term…

  16. Progress with the COGENT Edge Kinetic Code: Collision operator options

    DOE PAGES

    Dorf, M. A.; Cohen, R. H.; Compton, J. C.; ...

    2012-06-27

    In this study, COGENT is a continuum gyrokinetic code for edge plasmas being developed by the Edge Simulation Laboratory collaboration. The code is distinguished by application of the fourth order conservative discretization, and mapped multiblock grid technology to handle the geometric complexity of the tokamak edge. It is written in v∥-μ (parallel velocity – magnetic moment) velocity coordinates, and making use of the gyrokinetic Poisson equation for the calculation of a self-consistent electric potential. In the present manuscript we report on the implementation and initial testing of a succession of increasingly detailed collision operator options, including a simple drag-diffusion operatormore » in the parallel velocity space, Lorentz collisions, and a linearized model Fokker-Planck collision operator conserving momentum and energy (© 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim)« less

  17. Simulation of magnetic particles in microfluidic channels

    NASA Astrophysics Data System (ADS)

    Gusenbauer, Markus; Schrefl, Thomas

    2018-01-01

    In the field of biomedicine the applications of magnetic beads have increased immensely in the last decade. Drug delivery, magnetic resonance imaging, bioseparation or hyperthermia are only a small excerpt of their usage. Starting from microscaled particles the research is focusing more and more on nanoscaled particles. We are investigating and validating a method for simulating magnetic beads in a microfluidic flow which will help to manipulate beads in a controlled and reproducible manner. We are using the soft-matter simulation package ESPResSo to simulate magnetic particle dynamics in a lattice Boltzmann flow and applied external magnetic fields. Laminar as well as turbulent flow conditions in microfluidic systems can be analyzed while particles tend to agglomerate due to magnetic interactions. The proposed simulation methods are validated with experiments from literature.

  18. Bipolar Spintronics: From magnetic diodes to magnetic bipolar transistors

    NASA Astrophysics Data System (ADS)

    Zutic, Igor

    2004-03-01

    We develop a theory of bipolar (electrons and holes) spin-polarized transport [1,2] in semiconductors and discuss its implications for spintronic devices [3]. In our proposal for magnetic bipolar transistors [4,5] we show how bipolar spintronics can lead to spin and magnetic field controlled active devices, not limited by the magnetoresistive effects used in all-metallic structures [3]. We focus on magnetic p-n diodes [1,2] with spatially dependent spin splitting (Zeeman or exchange) of carrier bands. An exchange splitting can be provided by ferromagnetic semiconductors [6], while a large Zeeman splitting can be realized in the presence of magnetic field in magnetically doped or narrow band gap semiconductors [3]. Our theory of magnetic diodes [1,2] can be directly applied to magnetic bipolar transistors--the three-terminal devices which consist of two magnetic p-n diodes connected in series [4,5]. Predictions of exponentially large magnetoresistance [1] and a strong coupling between the spin and charge transport leading to the spin-voltaic effect [1,7] for magnetic diodes are also relevant for magnetic bipolar transistors. In particular, in n-p-n transistors, we show the importance of considering the nonequilibrium spin leading to the spin-voltaic effect. In addition to the applied magnetic filed, the injected nonequilibrium spin can be used to dynamically control the current amplification (gain). Recent experimental progress [8,9] supports the viability of our theoretical proposals. [1] I. Zutic, J. Fabian, S. Das Sarma, Phys. Rev. Lett. 88, 066603 (2002). [2] J. Fabian, I. Zutic, S. Das Sarma, Phys. Rev. B 66, 165301 (2002). [3] I. Zutic, J. Fabian, S. Das Sarma, Rev. Mod. Phys., in press. [4] J. Fabian, I. Zutic, S. Das Sarma, cond-mat/0211639; cond-mat/0307014, Appl. Phys. Lett., in press. [5] J. Fabian and I. Zutic, cond-mat/0311456. [6] H. Ohno, Science 281, 951 (1998). [7] I. Zutic, J. Fabian, S. Das Sarma, Appl. Phys. Lett. 82, 221 (2003). [8] N. Samarth

  19. Magnetoacoustic tomographic imaging of electrical impedance with magnetic induction

    PubMed Central

    Xia, Rongmin; Li, Xu; He, Bin

    2008-01-01

    Magnetoacoustic tomography with magnetic induction (MAT-MI) is a recently introduced method for imaging tissue electrical impedance properties by integrating magnetic induction and ultrasound measurements. In the present study, we have developed a focused cylindrical scanning mode MAT-MI system and the corresponding reconstruction algorithms. Using this system, we demonstrated 3-dimensional MAT-MI imaging in a physical phantom, with cylindrical scanning combined with ultrasound focusing, and the ability of MAT-MI in imaging electrical conductivity properties of biological tissue. PMID:19169372

  20. Magnetoacoustic tomographic imaging of electrical impedance with magnetic induction

    NASA Astrophysics Data System (ADS)

    Xia, Rongmin; Li, Xu; He, Bin

    2007-08-01

    Magnetoacoustic tomography with magnetic induction (MAT-MI) is a recently introduced method for imaging tissue electrical impedance properties by integrating magnetic induction and ultrasound measurements. In the present study, the authors have developed a focused cylindrical scanning mode MAT-MI system and the corresponding reconstruction algorithms. Using this system, they demonstrated a three-dimensional MAT-MI imaging approach in a physical phantom, with cylindrical scanning combined with ultrasound focusing, and the ability of MAT-MI in imaging electrical conductivity properties of biological tissue.