Dey, B.; Ratcliff, B.; Va’vra, J.
2017-02-16
In this article, we explore the angular resolution limits attainable in small FDIRC designs taking advantage of the new highly pixelated detectors that are now available. Since the basic FDIRC design concept attains its particle separation performance mostly in the angular domain as measured by two-dimensional pixels, this paper relies primarily on a pixel-based analysis, with additional chromatic corrections using the time domain, requiring single photon timing resolution at a level of 100–200 ps only. This approach differs from other modern DIRC design concepts such as TOP or TORCH detectors, whose separation performances rely more strongly on time-dependent analyses. Inmore » conclusion, we find excellent single photon resolution with a geometry where individual bars are coupled to a single plate, which is coupled in turn to a cylindrical lens focusing camera.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dey, B.; Ratcliff, B.; Va’vra, J.
In this article, we explore the angular resolution limits attainable in small FDIRC designs taking advantage of the new highly pixelated detectors that are now available. Since the basic FDIRC design concept attains its particle separation performance mostly in the angular domain as measured by two-dimensional pixels, this paper relies primarily on a pixel-based analysis, with additional chromatic corrections using the time domain, requiring single photon timing resolution at a level of 100–200 ps only. This approach differs from other modern DIRC design concepts such as TOP or TORCH detectors, whose separation performances rely more strongly on time-dependent analyses. Inmore » conclusion, we find excellent single photon resolution with a geometry where individual bars are coupled to a single plate, which is coupled in turn to a cylindrical lens focusing camera.« less
NASA Astrophysics Data System (ADS)
Nishimura, K.; Dey, B.; Aston, D.; Leith, D. W. G. S.; Ratcliff, B.; Roberts, D.; Ruckman, L.; Shtol, D.; Varner, G. S.; Va'vra, J.
2013-02-01
We present a detailed study of a novel Cherenkov imaging detector called the Focusing DIRC (FDIRC) with waveform digitizing electronics. In this study, the FDIRC prototype has been instrumented with seven Hamamatsu H-8500 MaPMTs. Waveforms from 384 pixels are digitized with waveform sampling electronics based on the BLAB2 ASIC, operating at a sampling speed of ∼2.5 GSa/s. The FDIRC prototype was tested in a large cosmic ray telescope (CRT) providing 3D muon tracks with ∼1.5 mrad angular resolution and muon energy of Emuon> 1.6 GeV. In this study we provide a detailed analysis of the tails in the Cherenkov angle distribution as a function of various variables, compare experimental results with simulation, and identify the major contributions to the tails. We demonstrate that to see the full impact of these tails on the Cherenkov angle resolution, it is crucial to use 3D tracks, and have a full understanding of the role of reconstruction ambiguities. These issues could not be fully explored in previous FDIRC studies where the beam was perpendicular to the quartz radiator bars. This work is relevant for the final FDIRC prototype of the PID detector at SuperB, which will be tested this year in the CRT setup.
NASA Astrophysics Data System (ADS)
Barbosa, F.; Bessuille, J.; Chudakov, E.; Dzhygadlo, R.; Fanelli, C.; Frye, J.; Hardin, J.; Kelsey, J.; Patsyuk, M.; Schwarz, C.; Schwiening, J.; Stevens, J.; Shepherd, M.; Whitlatch, T.; Williams, M.
2017-12-01
The GlueX DIRC (Detection of Internally Reflected Cherenkov light) detector is being developed to upgrade the particle identification capabilities in the forward region of the GlueX experiment at Jefferson Lab. The GlueX DIRC will utilize four existing decommissioned BaBar DIRC bar boxes, which will be oriented to form a plane roughly 4 m away from the fixed target of the experiment. A new photon camera has been designed that is based on the SuperB FDIRC prototype. The full GlueX DIRC system will consist of two such cameras, with the first planned to be built and installed in 2017. We present the current status of the design and R&D, along with the future plans of the GlueX DIRC detector.
Barbosa, F.; Bessuille, J.; Chudakov, E.; ...
2017-02-03
We present the GlueX DIRC (Detection of Internally Reflected Cherenkov light) detector that is being developed to upgrade the particle identification capabilities in the forward region of the GlueX experiment at Jefferson Lab. The GlueX DIRC will utilize four existing decommissioned BaBar DIRC bar boxes, which will be oriented to form a plane roughly 4 m away from the fixed target of the experiment. A new photon camera has been designed that is based on the SuperB FDIRC prototype. The full GlueX DIRC system will consist of two such cameras, with the first planned to be built and installed inmore » 2017. In addition, we present the current status of the design and R&D, along with the future plans of the GlueX DIRC detector.« less
Progress on Development of the New FDIRC PID Detector
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vavra, Jerry
2012-08-03
We present a progress status of a new concept of PID detector called FDIRC, intended to be used at the SuperB experiment, which requires {pi}/K separation up to a few GeV/c. The new photon camera is made of the solid fused-silica optics with a volume 25x smaller and speed increased by a factor of ten compared to the BaBar DIRC, and therefore will be much less sensitive to electromagnetic and neutron background
NASA Astrophysics Data System (ADS)
Schwiening, J.; Ali, A.; Belias, A.; Dzhygadlo, R.; Gerhardt, A.; Götzen, K.; Kalicy, G.; Krebs, M.; Lehmann, D.; Nerling, F.; Patsyuk, M.; Peters, K.; Schepers, G.; Schmitt, L.; Schwarz, C.; Traxler, M.; Böhm, M.; Eyrich, W.; Lehmann, A.; Pfaffinger, M.; Uhlig, F.; Düren, M.; Etzelmüller, E.; Föhl, K.; Hayrapetyan, A.; Kreutzfeld, K.; Merle, O.; Rieke, J.; Schmidt, M.; Wasem, T.; Achenbach, P.; Cardinali, M.; Hoek, M.; Lauth, W.; Schlimme, S.; Sfienti, C.; Thiel, M.
2018-03-01
The PANDA experiment at the international accelerator Facility for Antiproton and Ion Research in Europe (FAIR) near GSI, Darmstadt, Germany will address fundamental questions of hadron physics. Excellent Particle Identification (PID) over a large range of solid angles and particle momenta will be essential to meet the objectives of the rich physics program. Charged PID for the barrel region of the PANDA target spectrometer will be provided by a DIRC (Detection of Internally Reflected Cherenkov light) detector. The Barrel DIRC will cover the polar angle range of 22o-140o and cleanly separate charged pions from kaons for momenta between 0.5 GeV/c and 3.5 GeV/c with a separation power of at least 3 standard deviations. The design is based on the successful BABAR DIRC and the SuperB FDIRC R&D with several important improvements to optimize the performance for PANDA, such as a focusing lens system, fast timing, a compact fused silica prism as expansion region, and lifetime-enhanced Microchannel-Plate PMTs for photon detection. This article describes the technical design of the PANDA Barrel DIRC and the result of the design validation using a "vertical slice" prototype in hadronic particle beams at the CERN PS.
High-performance DIRC detector for the future Electron Ion Collider experiment
NASA Astrophysics Data System (ADS)
Kalicy, G.; Allison, L.; Cao, T.; Dzhygadlo, R.; Hartlove, T.; Horn, T.; Hyde, C.; Ilieva, Y.; Nadel-Turonski, P.; Park, K.; Peters, K.; Schwarz, C.; Schwiening, J.; Stevens, J.; Xi, W.; Zorn, C.
2018-04-01
Excellent particle identification (PID) is an essential requirement for a future Electron-Ion Collider (EIC) detector. Identification of the hadrons in the final state is critical to study how different quark flavors contribute to nucleon properties. A detector based on the Detection of Internally Reflected Cherenkov light (DIRC) principle, with a radial size of only a few cm, is a perfect solution for those requirements. The R&D process performed by the EIC PID consortium (eRD14) is focused on designing a high-performance DIRC that would extend the momentum coverage well beyond the state-of-the-art, allowing 3 standard deviations or more separation of π/K up to 6 GeV/c, e/π up to 1.8 GeV/c, and p/K up to 10 GeV/c. A key component to reach such a performance is a special 3-layer compound lens. This article describes the status of the High-Performance DIRC R&D for the EIC detector, with a focus on the detailed Monte Carlo simulation results and performance tests of the 3-layer lens.
DIRC Dreams: Research Directions for the Next Generation of Internally Reflected Imaging Counters
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ratcliff, Blair N.
1999-08-17
Some conceptual design features of the total internally reflecting,imaging Cherenkov counter (DIRC) are described. Limits of the DIRC approach to particle identification, and a few features of alternative DIRC designs, are briefly explored.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ratcliff, Blair N
Some conceptual design features of the total internally reflecting,imaging Cherenkov counter (DIRC) are described. Limits of the DIRC approach to particle identification, and a few features of alternative DIRC designs, are briefly explored.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ratcliff, Blair N
Some general conceptual design features of total internally reflecting, imaging Cherenkov counters (DIRCs) are described. Limits of the DIRC approach to particle identification and a few features of alternative DIRC designs are briefly explored.
R&D of a High-Performance DIRC Detector for a Future Electron-Ion Collider
NASA Astrophysics Data System (ADS)
Allison, Stacey Lee
An Electron-Ion Collider (EIC) is proposed as the next big scientific facility to be built in the United States, costing over $1 billion in design and construction. Each detector concept for the electron/ion beam interaction point is integrated into a large solenoidal magnet. The necessity for excellent hadronic particle identification (pion/kaon/proton) in the barrel region of the solenoid has pushed research and development (R&D) towards a new, high-performance Detection of Internally Reflected Cherenkov light (DIRC) detector design. The passage of a high energy charged particle through a fused silica bar of the DIRC generates optical Cherenkov radiation. A large fraction of this light propagates by total internal reflection to the end of the bar, where the photon trajectories expand in a large volume before reaching a highly segmented photo-detector array. The spatial and temporal distribution of the Cherenkov light at the photo-detector array allows one to reconstruct the angle of emission of the light relative to the incident charged particle track. In order to reach the desired performance of 3sigma pi/K separation at 6 GeV/c particle momentum a new 3-layer spherical lens focusing optic with a lanthanum crown glass central layer was designed to have a nearly flat focal plane. In order to validate the EIC DIRC simulation package, a synergistic test beam campaign was carried out in 2015 at the CERN PS with the PANDA Barrel DIRC group using a prototype DIRC detector. Along with the analysis of the CERN test beam data, measurements of the focal plane of the 3-layer lens were performed using a custom-built laser setup at Old Dominion University. Radiation hardness of the lanthanum crown glass was tested using a 160 keV X-ray source and a monochromator at the Catholic University of America. Results of these test-bench experiments and the analysis of the 2015 CERN test beam data are presented here.
R&D of a high-performance DIRC detector for a future electron-ion collider
DOE Office of Scientific and Technical Information (OSTI.GOV)
Allison, Staceu L.
An Electron-Ion Collider (EIC) is proposed as the next big scientific facility to be built in the United States, costing over $1 billion in design and construction. Each detector concept for the electron/ion beam interaction point is integrated into a large solenoidal magnet. The necessity for excellent hadronic particle identification (pion/kaon/proton) in the barrel region of the solenoid has pushed research and development (R&D) towards a new, high-performance Detection of Internally Reflected Cherenkov light (DIRC) detector design. The passage of a high energy charged particle through a fused silica bar of the DIRC generates optical Cherenkov radiation. A large fractionmore » of this light propagates by total internal reflection to the end of the bar, where the photon trajectories expand in a large volume before reaching a highly segmented photo-detector array. The spatial and temporal distribution of the Cherenkov light at the photo-detector array allows one to reconstruct the angle of emission of the light relative to the incident charged particle track. In order to reach the desired performance of 3sigma pi/K separation at 6 GeV/c particle momentum a new 3-layer spherical lens focusing optic with a lanthanum crown glass central layer was designed to have a nearly at focal plane. In order to validate the EIC DIRC simulation package, a synergistic test beam campaign was carried out in 2015 at the CERN PS with the PANDA Barrel DIRC group using a prototype DIRC detector. Along with the analysis of the CERN test beam data, measurements of the focal plane of the 3-layer lens were performed using a custom-built laser setup at Old Dominion University. Radiation hardness of the lanthanum crown glass was tested using a 160 keV X-ray source and a monochromator at the Catholic University of America. Results of these test-bench experiments and the analysis of the 2015 CERN test beam data are presented here.« less
The PANDA DIRC detectors at FAIR
NASA Astrophysics Data System (ADS)
Schwarz, C.; Ali, A.; Belias, A.; Dzhygadlo, R.; Gerhardt, A.; Götzen, K.; Kalicy, G.; Krebs, M.; Lehmann, D.; Nerling, F.; Patsyuk, M.; Peters, K.; Schepers, G.; Schmitt, L.; Schwiening, J.; Traxler, M.; Zühlsdorf, M.; Böhm, M.; Britting, A.; Eyrich, W.; Lehmann, A.; Pfaffinger, M.; Uhlig, F.; Düren, M.; Etzelmüller, E.; Föhl, K.; Hayrapetyan, A.; Kreutzfeld, K.; Kröck, B.; Merle, O.; Rieke, J.; Schmidt, M.; Wasem, T.; Achenbach, P.; Cardinali, M.; Hoek, M.; Lauth, W.; Schlimme, S.; Sfienti, C.; Thiel, M.; Allison, L.; Hyde, C.
2017-07-01
The PANDA detector at the international accelerator Facility for Antiproton and Ion Research in Europe (FAIR) addresses fundamental questions of hadron physics. An excellent hadronic particle identification (PID) will be accomplished by two DIRC (Detection of Internally Reflected Cherenkov light) counters in the target spectrometer. The design for the barrel region covering polar angles between 22o to 140o is based on the successful BABAR DIRC with several key improvements, such as fast photon timing and a compact imaging region. The novel Endcap Disc DIRC will cover the smaller forward angles between 5o (10o) to 22o in the vertical (horizontal) direction. Both DIRC counters will use lifetime-enhanced microchannel plate PMTs for photon detection in combination with fast readout electronics. Geant4 simulations and tests with several prototypes at various beam facilities have been used to evaluate the designs and validate the expected PID performance of both PANDA DIRC counters.
A digital FDIRC prototype for isotopic identification in astroparticle physics
NASA Astrophysics Data System (ADS)
Suh, J. E.; Marrocchesi, P. S.; Bigongiari, G.; Brogi, P.; Collazuol, G.; Sulaj, A.
2017-12-01
Experimental results obtained with a prototype of a Focused Internal Reflection Cherenkov, equipped with 16 high-granularity arrays of NUV-SiPM and tested at CERN SPS in March 2015, are discussed. The detector was exposed to relativistic ions of 13, 19 and 30 GeV/amu obtained from fragmentation of a primary Ar beam. The FDIRC included a single Fused Silica radiator bar optically connected to a cylindrical mirror and an imaging focal plane of dimensions ∼4 cm×∼3 cm, covered with a total of 1024 SiPM photosensors. It was operated in photon counting mode thanks to the excellent performance of the SiPM arrays. The complete simulation of the detector was extended to the case of a planar device with multiple bars covering a sensitive area of the order of 1 m2. MC simulation is performed to evaluate its expected mass resolution for the identification of cosmic isotopes of astrophysical interest as 9Be and 10Be at energies of several GeV/amu with the goal to extend the energy reach of the present available data.
Fabrication of DIRC radiator bars and plates at InSync, Inc.
NASA Astrophysics Data System (ADS)
Tonnessen, T. W.
2017-12-01
Fabrication of quality radiator bars and plates is paramount to a successful DIRC project. This write up discusses the trials and tribulations of the manufacture of ~600 bars for the BaBar DIRC project and discusses the history and current capabilities of InSync, Inc.
NASA Astrophysics Data System (ADS)
Föhl, K.; Ali, A.; Belias, A.; Dzhygadlo, R.; Gerhardt, A.; Götzen, K.; Kalicy, G.; Krebs, M.; Lehmann, D.; Nerling, F.; Patsyuk, M.; Peters, K.; Schepers, G.; Schmitt, L.; Schwarz, C.; Schwiening, J.; Traxler, M.; Böhm, M.; Eyrich, W.; Lehmann, A.; Pfaffinger, M.; Uhlig, F.; Düren, M.; Etzelmüller, E.; Hayrapetyan, A.; Kreutzfeld, K.; Merle, O.; Rieke, J.; Schmidt, M.; Wasem, T.; Achenbach, P.; Cardinali, M.; Hoek, M.; Lauth, W.; Schlimme, S.; Sfienti, C.; Thiel, M.
2018-02-01
Positively identifying charged kaons in the PANDA forward endcap solid angle range can be achieved with the Endcap Disc DIRC, allowing kaon-pion separation from 1 up to 4 GeV/c with a separation power of at least 3 standard deviations. Design, performance, and components of this DIRC are given, including the recently introduced TOFPET-ASIC based read-out. Results of a prototype operated in a test beam at DESY in 2016 are shown.
Stevens, J.; Barbosa, F.; Bessuille, J.; ...
2016-07-20
Here, the GlueX experiment was designed to search for and study the pattern of gluonic excitations in the meson spectrum produced through photoproduction reactions at a new tagged photon beam facility in Hall D at Jefferson Laboratory. The particle identification capabilities of the GlueX experiment will be enhanced by constructing a DIRC (Detection of Internally Reflected Cherenkov light) detector, utilizing components of the decommissioned BaBar DIRC. The DIRC will allow systematic studies of kaon final states that are essential for inferring the quark flavor content of both hybrid and conventional mesons. In this contribution, the design for the GlueX DIRCmore » will be discussed including new expansion volumes, read out with MaPMTs, that are currently under development.« less
The DIRC front-end electronics chain for BaBar
NASA Astrophysics Data System (ADS)
Bailly, P.; Chauveau, J.; Del Buono, L.; Genat, J. F.; Lebbolo, H.; Roos, L.; Zhang, B.; Beigbeder, C.; Bernier, R.; Breton, D.; Caceres, T.; Chase, R.; Ducorps, A.; Hrisoho, A.; Imbert, P.; Sen, S.; Tocut, V.; Truong, K.; Wormser, G.; Zomer, F.; Bonneaud, G.; Dohou, F.; Gastaldi, F.; Matricon, P.; Renard, C.; Thiebaux, C.; Vasileiadis, G.; Verderi, M.; Oxoby, G.; Va'Vra, J.; Warner, D.; Wilson, R. J.
1999-08-01
The detector of Internally Reflected Cherenkov light (DIRC) of the BaBar detector (SLAC Stanford, USA) measures better than 1 ns the arrival time of Cherenkov photoelectrons, detected in a 11 000 phototubes array and their amplitude spectra. It mainly comprises of 64-channel DIRC Front-End Boards (DFB) equipped with eight full-custom Analog chips performing zero-cross discrimination with 2 mV threshold and pulse shaping, four full-custom Digital TDC chips for timing measurements with 500 ps binning and a readout logic selecting hits in the trigger window, and DIRC Crate Controller cards (DCC) serializing the data collected from up to 16 DFBs onto a 1.2 Gb/s optical link. Extensive test of the pre-production chips have been performed as well as system tests.
The DIRC front-end electronics chain for BaBar
NASA Astrophysics Data System (ADS)
Bailly, P.; Beigbeder, C.; Bernier, R.; Breton, D.; Bonneaud, G.; Caceres, T.; Chase, R.; Chauveau, J.; Del Buono, L.; Dohou, F.; Ducorps, A.; Gastaldi, F.; Genat, J. F.; Hrisoho, A.; Imbert, P.; Lebbolo, H.; Matricon, P.; Oxoby, G.; Renard, C.; Roos, L.; Sen, S.; Thiebaux, C.; Truong, K.; Tocut, V.; Vasileiadis, G.; Va'Vra, J.; Verderi, M.; Warner, D.; Wilson, R. J.; Wormser, G.; Zhang, B.; Zomer, F.
2000-12-01
Recent results from the Front-End electronics of the Detector of Internally Reflected Cerenkov light (DIRC) for the BaBar experiment at SLAC (Stanford, USA) are presented. It measures to better than 1 ns the arrival time of Cerenkov photoelectrons detected in a 11000 phototubes array and their amplitude spectra. It mainly comprises 64-channel DIRC Front-End Boards (DFB) equipped with eight full-custom analog chips performing zero-cross discrimination with 2 mV threshold and pulse shaping, four full-custom digital time to digital chips (TDC) for timing measurements with 500 ps binning and a readout logic selecting hits in the trigger window, and DIRC Crate Controller cards (DCC) serializing the data collected front up to 16 DFBs onto a 1.2 Gb/s optical link. Extensive test results of the pre-production chips are presented, as well as system tests.
Measurement of the D - s Decay Constant f Ds and Observation of New Charm Resonances Decaying to D*π
DOE Office of Scientific and Technical Information (OSTI.GOV)
Benitez, Jose
2012-03-01
The absolute branching fractions for the decays D - s → ℓ-more » $$\\bar{v}$$ -(ℓ = e, μ, or τ) are measured using a data sample corresponding to an integrated luminosity of 521 fb -1 collected at center of mass energies near 10.58 GeV with the BABAR detector at the PEPII e +e - collider at SLAC. The number of D s - mesons is determined by reconstructing the recoiling system DKXγ in events of the type e +e - → DKXD* s -, where D* s - → D s - γ and X represents additional pions from fragmentation. The D s - → ℓ -v ℓ events are detected by full or partial reconstruction of the recoiling system DKX{gamma}ℓ. The following results are obtained: β(D s - → μ -v) = (6.02 ± 0.38 ± 0.34) x 10 -3, {Beta}(D s -→ τ -v) = (5.00 ± 0.35 ± 0.49) x 10 -2, and B(D s - → e -ν) < 2.8 x 10 -4 at 90% C.L., where the first uncertainty is statistical and the second is systematic. The branching fraction measurements are combined to determine the D s - decay constant f Ds = (258.6 ± 6.4 ± 7.5) MeV. In addition, a study has been performed of the D +π} -, D 0π} +, and D* +π - systems in inclusive e +e - → c c interactions in a search for excited D meson states. The dataset used consists of {approx}454 fb -1. The mass spectra for these systems show, for the first time, candidates for the radial excitations of the D 0, D* 0, and D* +, as well as the L = 2 excited states of the D 0 and D -, where L is the orbital angular momentum of the quarks. Finally, a prototype of a next generation Detector of Internally Reflected Cherenkov radiation (Focusing DIRC) has been tested using a 10 GeV electron beam at SLAC. The Focusing DIRC is based on the DIRC which was used in the BABAR detector, but has new pixel photon detectors which improve the resolution on the single photon time of propagation by about an order of magnitude allowing, for the first time, to correct the chromatic smearing in the Cherenkov angle. The Focusing DIRC may be used in a future Super-B factory.« less
Padek, Margaret; Mir, Nageen; Jacob, Rebekah R; Chambers, David A; Dobbins, Maureen; Emmons, Karen M; Kerner, Jon; Kumanyika, Shiriki; Pfund, Christine; Proctor, Enola K; Stange, Kurt C; Brownson, Ross C
2018-01-22
As the field of D&I (dissemination and implementation) science grows to meet the need for more effective and timely applications of research findings in routine practice, the demand for formalized training programs has increased concurrently. The Mentored Training for Dissemination and Implementation Research in Cancer (MT-DIRC) Program aims to build capacity in the cancer control D&I research workforce, especially among early career researchers. This paper outlines the various components of the program and reports results of systematic evaluations to ascertain its effectiveness. Essential features of the program include selection of early career fellows or more experienced investigators with a focus relevant to cancer control transitioning to a D&I research focus, a 5-day intensive training institute, ongoing peer and senior mentoring, mentored planning and work on a D&I research proposal or project, limited pilot funding, and training and ongoing improvement activities for mentors. The core faculty and staff members of the MT-DIRC program gathered baseline and ongoing evaluation data regarding D&I skill acquisition and mentoring competency through participant surveys and analyzed it by iterative collective reflection. A majority (79%) of fellows are female, assistant professors (55%); 59% are in allied health disciplines, and 48% focus on cancer prevention research. Forty-three D&I research competencies were assessed; all improved from baseline to 6 and 18 months. These effects were apparent across beginner, intermediate, and advanced initial D&I competency levels and across the competency domains. Mentoring competency was rated very highly by the fellows--higher than rated by the mentors themselves. The importance of different mentoring activities, as rated by the fellows, was generally congruent with their satisfaction with the activities, with the exception of relatively greater satisfaction with the degree of emotional support and relatively lower satisfaction for skill building and opportunity initially. These first years of MT-DIRC demonstrated the program's ability to attract, engage, and improve fellows' competencies and skills and implement a multicomponent mentoring program that was well received. This account of the program can serve as a basis for potential replication and evolution of this model in training future D&I science researchers.
NASA Astrophysics Data System (ADS)
Düren, M.; Etzelmüller, E.; Föhl, K.; Hayrapetyan, A.; Kröck, B.; Merle, O.; Rieke, J.; Schmidt, M.; Wasem, T.; Britting, A.; Eyrich, W.; Lehmann, A.; Pfaffinger, M.; Uhlig, F.; Belias, A.; Dzhygadlo, R.; Gerhardt, A.; Götzen, K.; Kalicy, G.; Krebs, M.; Lehmann, D.; Nerling, F.; Patsyuk, M.; Peters, K.; Schepers, G.; Schmitt, L.; Schwarz, C.; Schwiening, J.; Traxler, M.; Zühlsdorf, M.; Cowie, E.; Keri, T.; Achenbach, P.; Cardinali, M.; Hoek, M.; Lauth, W.; Schlimme, S.; Sfienti, C.; Thiel, M.
2017-12-01
The Endcap Disc DIRC (EDD) for PANDA has been designed to identify traversing pions, kaons and protons in the future PANDA experiment. Its central part is a 2 cm thick fused silica plate. Focussing optics are attached to the outer rim of the plate, outside of the acceptance of the experiment. Fast, high-resolution MCP-PMTs, designed to register single Cherenkov photons, have been tested in magnetic field. Filters limit the spectral acceptance of the sensors to reduce dispersion effects and to extend their lifetime. A compact and fast readout is realized with ASICs. Analytical reconstruction algorithms allow for fast particle identification. The angular resolution of a DIRC prototype has been simulated in Monte Carlo and confirmed in a test beam. The final detector will be able to provide a 4 σπ / K separation up to a momentum of 4 GeV / c .
Performance simulation of BaBar DIRC bar boxes in TORCH
NASA Astrophysics Data System (ADS)
Föhl, K.; Brook, N.; Castillo García, L.; Cussans, D.; Forty, R.; Frei, C.; Gao, R.; Gys, T.; Harnew, N.; Piedigrossi, D.; Rademacker, J.; Ros García, A.; van Dijk, M.
2017-12-01
TORCH is a large-area precision time-of-flight detector based on the DIRC principle. The DIRC bar boxes of the BaBar experiment at SLAC could possibly be reused to form a part of the TORCH detector time-of-flight wall area, proposed to provide positive particle identification of low momentum kaons in the LHCb experiment at CERN. For a potential integration of BaBar bar boxes into TORCH, new imaging readout optics are required. From the several designs of readout optics that have been considered, two are used in this paper to study the effect of BaBar bar optical imperfections on the detector reconstruction performance. The kaon-pion separation powers obtained from analysing simulated photon hit patterns show the performance reduction for a BaBar bar of non-square geometry compared to a perfectly rectangular cross section.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Va'Vra, J.
The publication of the ICFA Instrumentation Bulletin is an activity of the Panel on Future Innovation and Development of ICFA (International Committee for Future Accelerators). The Bulletin reports on research and progress in the field of instrumentation with emphasis on application in the field of high-energy physics. It encourages issues of generic instrumentation. This volume contains the following articles: (1) ''Gaseous Micropattern Detectors: High-Energy Physics and Beyond''; (2) ''DIRC Dreams Redux: Research Directions for the Next Generation of Internally Reflected Imaging Counters''; and (3) ''Corrosion of Glass Windows in DIRC PMTs''.
Frontend electronics for high-precision single photo-electron timing using FPGA-TDCs
NASA Astrophysics Data System (ADS)
Cardinali, M.; Dzyhgadlo, R.; Gerhardt, A.; Götzen, K.; Hohler, R.; Kalicy, G.; Kumawat, H.; Lehmann, D.; Lewandowski, B.; Patsyuk, M.; Peters, K.; Schepers, G.; Schmitt, L.; Schwarz, C.; Schwiening, J.; Traxler, M.; Ugur, C.; Zühlsdorf, M.; Dodokhov, V. Kh.; Britting, A.; Eyrich, W.; Lehmann, A.; Uhlig, F.; Düren, M.; Föhl, K.; Hayrapetyan, A.; Kröck, B.; Merle, O.; Rieke, J.; Cowie, E.; Keri, T.; Montgomery, R.; Rosner, G.; Achenbach, P.; Corell, O.; Ferretti Bondy, M. I.; Hoek, M.; Lauth, W.; Rosner, C.; Sfienti, C.; Thiel, M.; Bühler, P.; Gruber, L.; Marton, J.; Suzuki, K.
2014-12-01
The next generation of high-luminosity experiments requires excellent particle identification detectors which calls for Imaging Cherenkov counters with fast electronics to cope with the expected hit rates. A Barrel DIRC will be used in the central region of the Target Spectrometer of the planned PANDA experiment at FAIR. A single photo-electron timing resolution of better than 100 ps is required by the Barrel DIRC to disentangle the complicated patterns created on the image plane. R&D studies have been performed to provide a design based on the TRB3 readout using FPGA-TDCs with a precision better than 20 ps RMS and custom frontend electronics with high-bandwidth pre-amplifiers and fast discriminators. The discriminators also provide time-over-threshold information thus enabling walk corrections to improve the timing resolution. Two types of frontend electronics cards optimised for reading out 64-channel PHOTONIS Planacon MCP-PMTs were tested: one based on the NINO ASIC and the other, called PADIWA, on FPGA discriminators. Promising results were obtained in a full characterisation using a fast laser setup and in a test experiment at MAMI, Mainz, with a small scale DIRC prototype.
Optical Properties of the DIRC Fused Silica Radiator
DOE Office of Scientific and Technical Information (OSTI.GOV)
Convery, Mark R
2003-04-15
The DIRC detector is successfully operating as the hadronic particle identification system for the BaBar experiment at SLAC. The production of its Cherenkov radiator required much effort in practice, both in manufacture and conception, which in turn required a large number of R&D measurements. One of the major outcomes of this R&D work was an understanding of methods to select radiation hard and optically uniform fused silica material. Others included measurement of the wavelength dependency of the internal reflection coefficient, and its sensitivity to the surface pollution, selection of the radiator support, selection of good optical glue, etc. This notemore » summarizes the optical R&D test results.« less
Particle identification algorithms for the PANDA Endcap Disc DIRC
NASA Astrophysics Data System (ADS)
Schmidt, M.; Ali, A.; Belias, A.; Dzhygadlo, R.; Gerhardt, A.; Götzen, K.; Kalicy, G.; Krebs, M.; Lehmann, D.; Nerling, F.; Patsyuk, M.; Peters, K.; Schepers, G.; Schmitt, L.; Schwarz, C.; Schwiening, J.; Traxler, M.; Böhm, M.; Eyrich, W.; Lehmann, A.; Pfaffinger, M.; Uhlig, F.; Düren, M.; Etzelmüller, E.; Föhl, K.; Hayrapetyan, A.; Kreutzfeld, K.; Merle, O.; Rieke, J.; Wasem, T.; Achenbach, P.; Cardinali, M.; Hoek, M.; Lauth, W.; Schlimme, S.; Sfienti, C.; Thiel, M.
2017-12-01
The Endcap Disc DIRC has been developed to provide an excellent particle identification for the future PANDA experiment by separating pions and kaons up to a momentum of 4 GeV/c with a separation power of 3 standard deviations in the polar angle region from 5o to 22o. This goal will be achieved using dedicated particle identification algorithms based on likelihood methods and will be applied in an offline analysis and online event filtering. This paper evaluates the resulting PID performance using Monte-Carlo simulations to study basic single track PID as well as the analysis of complex physics channels. The online reconstruction algorithm has been tested with a Virtex4 FGPA card and optimized regarding the resulting constraints.
Lifetime of MCP-PMTs and other performance features
NASA Astrophysics Data System (ADS)
Lehmann, A.; Böhm, M.; Eyrich, W.; Miehling, D.; Pfaffinger, M.; Stelter, S.; Uhlig, F.; Ali, A.; Belias, A.; Dzhygadlo, R.; Gerhardt, A.; Götzen, K.; Kalicy, G.; Krebs, M.; Lehmann, D.; Nerling, F.; Patsyuk, M.; Peters, K.; Schepers, G.; Schmitt, L.; Schwarz, C.; Schwiening, J.; Traxler, M.; Düren, M.; Etzelmüller, E.; Föhl, K.; Hayrapetyan, A.; Kreutzfeld, K.; Merle, O.; Rieke, J.; Schmidt, M.; Wasem, T.; Achenbach, P.; Cardinali, M.; Hoek, M.; Lauth, W.; Schlimme, S.; Sfienti, C.; Thiel, M.
2018-02-01
The bar PANDA experiment at FAIR will use DIRC detectors for the separation of hadrons. The compactness of the bar PANDA detector requires the image planes of these detectors to be placed inside the magnetic field of the solenoid. Due to this and other boundary conditions MCP-PMTs were identified as the only suitable photon sensors. Until recently the major obstacle for an application of MCP-PMTs in high rate experiments like bar PANDA were serious aging problems which led to damage at the photo-cathode and a fast declining quantum efficiency as the integrated anode charge (IAC) increased. With new countermeasures against the aging, in particular due to the application of an atomic layer deposition (ALD) technique to coat the MCP pores, the lifetime of MCP-PMTs has meanwhile increased by a factor >50 which is fully sufficient for bar PANDA. The recent results of our long-term lifetime measurements are discussed. New 2-inch MCP-PMT prototypes from Hamamatsu show an encouraging behavior. However, the currently best performing MCP-PMT is a 2-inch PHOTONIS tube with two ALD-layers which reaches an IAC of >16 C/cm2 without any visible sign of aging. In the second part of these proceedings a new data acquisition system of the PADIWA/TRB type is presented which allows a quasi-parallel measurement of many MCP-PMT performance parameters. Especially unwanted effects like dark-count rate, crosstalk, ion after-pulsing, and recoil electrons can be studied in more detail than ever before. Exemplary results for these parameters are shown. The discussed DAQ system will be used for the comprehensive data quality checks of the MCP-PMTs being built into the DIRCs.
Recent developments with microchannel-plate PMTs
NASA Astrophysics Data System (ADS)
Lehmann, A.; Böhm, M.; Britting, A.; Eyrich, W.; Pfaffinger, M.; Uhlig, F.; Belias, A.; Dzhygadlo, R.; Gerhardt, A.; Götzen, K.; Kalicy, G.; Krebs, M.; Lehmann, D.; Nerling, F.; Patsyuk, M.; Peters, K.; Schepers, G.; Schmitt, L.; Schwarz, C.; Schwiening, J.; Traxler, M.; Zühlsdorf, M.; Düren, M.; Etzelmüller, E.; Föhl, K.; Hayrapetyan, A.; Kröck, B.; Merle, O.; Rieke, J.; Schmidt, M.; Wasem, T.; Cowie, E.; Keri, T.; Achenbach, P.; Cardinali, M.; Hoek, M.; Lauth, W.; Schlimme, S.; Sfienti, C.; Thiel, M.
2017-12-01
Microchannel-plate (MCP) PMTs are the favored photon sensors for the DIRC detectors of the PANDA experiment at FAIR. Until recently the main drawback of MCP-PMTs were serious aging effects which led to a limited lifetime due to a rapidly decreasing quantum efficiency (QE) of the photo cathode (PC) as the integrated anode charge (IAC) increased. In the latest models of PHOTONIS and Hamamatsu an innovative atomic layer deposition (ALD) technique is applied to overcome these limitations. During the last five years comprehensive aging tests with ALD coated MCP-PMTs were performed and the results were compared to tubes treated with other techniques. The QE in dependence of the IAC was measured as a function of the wavelength and the position across the PC. For the best performing tubes the lifetime improvement in comparison to the older MCP-PMTs is a factor of > 50 based on an IAC of meanwhile > 10 C /cm2 . In addition, the performance results of a new 2-in. ALD coated MCP-PMT prototype from Hamamatsu with a very high position resolution (128×6 anode pixels) is presented and the first conclusions from investigations concerning the PC aging mechanism will be discussed.
NASA Astrophysics Data System (ADS)
Barber, Corinne; DIRC at EIC Collaboration
2015-10-01
The High-B test facility at Thomas Jefferson National Accelerator Facility allows researchers to evaluate the gain of compact photon sensors, such as Micro-Channel-Plate Photomultipliers (MCP-PMTs), in magnetic fields up to 5 T. These ongoing studies support the development of a Detector of Internally Reflected Cherenkov light (DIRC) to be used in an Electron Ion Collider (EIC). Here, we present our summer 2015 activities to upgrade and improve the facility, and we show results for MCP-PMT gain changes in high B-fields. To monitor the light stability delivered to the MCP-PMTs being tested, we implemented a Silicon Photomultiplier (SiPM) in the setup and calibrated the ADC reading this sensor. A 405-nm Light-Emitting Diode (LED) housed in an optical tube compatible with neutral density filters was also installed. The filters provide an alternative way of reducing the light output of the LED to operate the MCP-PMTs in a single-photon mode. We calibrated a set of filters by means of a photodiode and measured the photon flux at multiple positions relative to the LED. This information helped us to design 3D-printed holders unique to each MCP-PMT so that the photocathode receives the greatest amount of light. The improvements to the setup allow for more precise PMT gain evaluation. This team includes 7 collaborators/co-authors besides myself: Yordanka Ilieva, Kijun Park, Greg Kalicy, Carl Zorn, Pawel Nadel-Turonski, Tongtong Cao, and Lee.
Impact of Scanning Density on Measurements from Spectral Domain Optical Coherence Tomography
Keane, Pearse A.; Ouyang, Yanling; Updike, Jared F.; Walsh, Alexander C.
2010-01-01
Purpose. To investigate the relationship between B-scan density and retinal thickness measurements obtained by spectral domain optical coherence tomography (SDOCT) in eyes with retinal disease. Methods. Data were collected from 115 patients who underwent volume OCT imaging with Cirrus HD-OCT using the 512 × 128 horizontal raster protocol. Raw OCT data, including the location of the automated retinal boundaries, were exported from the Cirrus HD-OCT instrument and imported into the Doheny Image Reading Center (DIRC) OCT viewing and grading software, termed “3D-OCTOR.” For each case, retinal thickness maps similar to those produced by Cirrus HD-OCT were generated using all 128 B-scans, as well as using less dense subsets of scans, ranging from every other scan to every 16th scan. Retinal thickness measurements derived using only a subset of scans were compared to measurements using all 128 B-scans, and differences for the foveal central subfield (FCS) and total macular volume were computed. Results. The mean error in FCS retinal thickness measurement increased as the density of B-scans decreased, but the error was small (<2 μm), except at the sparsest densities evaluated. The maximum error at a density of every fourth scan (32 scans spaced 188 μm apart) was <1%. Conclusions. B-scan density in volume SDOCT acquisitions can be reduced to 32 horizontal B-scans (spaced 188 μm apart) with minimal change in calculated retinal thickness measurements. This information may be of value in design of scanning protocols for SDOCT for use in future clinical trials. PMID:19797199
Novel genome-wide association study-based candidate loci for differentiated thyroid cancer risk.
Figlioli, Gisella; Köhler, Aleksandra; Chen, Bowang; Elisei, Rossella; Romei, Cristina; Cipollini, Monica; Cristaudo, Alfonso; Bambi, Franco; Paolicchi, Elisa; Hoffmann, Per; Herms, Stefan; Kalemba, Michał; Kula, Dorota; Pastor, Susana; Marcos, Ricard; Velázquez, Antonia; Jarząb, Barbara; Landi, Stefano; Hemminki, Kari; Försti, Asta; Gemignani, Federica
2014-10-01
Genome-wide association studies (GWASs) on differentiated thyroid cancer (DTC) have identified robust associations with single nucleotide polymorphisms (SNPs) at 9q22.33 (FOXE1), 14q13.3 (NKX2-1), and 2q35 (DIRC3). Our recently published GWAS suggested additional susceptibility loci specific for the high-incidence Italian population. The purpose of this study was to identify novel Italian-specific DTC risk variants based on our GWAS and to test them further in low-incidence populations. We investigated 45 SNPs selected from our GWAS first in an Italian population. SNPs that showed suggestive evidence of association were investigated in the Polish and Spanish cohorts. The combined analysis of the GWAS and the Italian replication study (2260 case patients and 2218 control subjects) provided strong evidence of association with rs10136427 near BATF (odds ratio [OR] =1.40, P = 4.35 × 10(-7)) and rs7267944 near DHX35 (OR = 1.39, P = 2.13 × 10(-8)). A possible role in DTC susceptibility in the Italian populations was also found for rs13184587 (ARSB) (P = 8.54 × 10(-6)) and rs1220597 (SPATA13) (P = 3.25 × 10(-6)). Only the associations between rs10136427 and rs7267944 and DTC risk were replicated in the Polish and the Spanish populations with little evidence of population heterogeneity (GWAS and all replications combined, OR = 1.30, P = 9.30 × 10(-7) and OR = 1.32, P = 1.34 × 10(-8), respectively). In silico analyses provided new insights into the possible functional consequences of the SNPs that showed the strongest association with DTC. Our findings provide evidence for novel DTC susceptibility variants. Further studies are warranted to identify the specific genetic variants responsible for the observed associations and to functionally validate our in silico predictions.
[Pre-verbality in focusing and the need for self check. An attempt at "focusing check"].
Masui, T; Ikemi, A; Murayama, S
1983-06-01
Though the Focusing process is not entirely non-verbal, in Focusing, careful attention is paid by the Focuser and the Listener to the pre-verbal experiential process. In other words, Focusing involves attending to the felt sense that is not easily expressed in words immediately. Hence, during the process of learning to Focus, the Focusing teacher attempts to communicate the experiences of Focusing to the student which are not easily done by words. Due to such difficulties, the Focusing student may (and quite frequently does) mistake the experiential process in Focusing with other processes. Often, the felt sense can be confused with other phenomena such as "autogenic discharge". Also the Focuser may not stay with the felt sense and drift into "free association" or frequently, certain processes in "meditation" can be confused with Focusing. Therefore, there is a need for a "check" by which the Focusing student can confirm the Focusing experience for himself. For the Focusing student, such a "check" serves not only to confirm the Focusing process, but also an aid to learning Focusing. We will report here a "Focusing Check" which we developed by translating Eugene Gendlin's "Focusing Check" and making several modifications in it so that it will be more understandable to the Japanese. Along with the "Focusing Check" we developed, the authors discuss the need for such a check.
Focus control enhancement and on-product focus response analysis methodology
NASA Astrophysics Data System (ADS)
Kim, Young Ki; Chen, Yen-Jen; Hao, Xueli; Samudrala, Pavan; Gomez, Juan-Manuel; Mahoney, Mark O.; Kamalizadeh, Ferhad; Hanson, Justin K.; Lee, Shawn; Tian, Ye
2016-03-01
With decreasing CDOF (Critical Depth Of Focus) for 20/14nm technology and beyond, focus errors are becoming increasingly critical for on-product performance. Current on product focus control techniques in high volume manufacturing are limited; It is difficult to define measurable focus error and optimize focus response on product with existing methods due to lack of credible focus measurement methodologies. Next to developments in imaging and focus control capability of scanners and general tool stability maintenance, on-product focus control improvements are also required to meet on-product imaging specifications. In this paper, we discuss focus monitoring, wafer (edge) fingerprint correction and on-product focus budget analysis through diffraction based focus (DBF) measurement methodology. Several examples will be presented showing better focus response and control on product wafers. Also, a method will be discussed for a focus interlock automation system on product for a high volume manufacturing (HVM) environment.
External Versus Two Different Internal Foci of Attention in Long-Distance Throwing.
Oki, Yuta; Kokubu, Masahiro; Nakagomi, Shiro
2018-02-01
The present study examined the influence of attentional focus on performance during a long-distance throwing task. Twelve participants executed three maximum-effort, long-distance baseball throwing attempts in three focus conditions: internal focus on wrist flexion (wrist internal focus), internal focus on the separation between pelvis and upper torso orientations (torso internal focus), and external focus on the ball path (external focus). Compared with the external focus and torso internal focus conditions, performance was poorer in the wrist internal focus condition. Performances were not different in the torso internal and external focus conditions. In addition, attentional focus affected the release angle of the ball but not its initial velocity. Our results reveal that the body part targeted for internal focus of attention and the forcefulness of the motor activity can be as important to motor performance as whether the attention is internal or external.
Autofocus system and autofocus method for focusing on a surface
O'Neill, Mary Morabito
2017-05-23
An autofocus system includes an imaging device, a lens system and a focus control actuator that is configured to change a focus position of the imaging device in relation to a stage. The electronic control unit is configured to control the focus control actuator to a plurality of predetermined focus positions, and activate the imaging device to obtain an image at predetermined positions and then apply a spatial filter to the obtained images. This generates a filtered image for the obtained images. The control unit determines a focus score for the filtered images such that the focus score corresponds to a degree of focus in the obtained images. The control unit identifies a best focus position by comparing the focus score of the filtered images, and controls the focus control actuator to the best focus position corresponding to the highest focus score.
Technology of focus detection for 193nm projection lithographic tool
NASA Astrophysics Data System (ADS)
Di, Chengliang; Yan, Wei; Hu, Song; Xu, Feng; Li, Jinglong
2012-10-01
With the shortening printing wavelength and increasing numerical aperture of lithographic tool, the depth of focus(DOF) sees a rapidly drop down trend, reach a scale of several hundred nanometers while the repeatable accuracy of focusing and leveling must be one-tenth of DOF, approximately several dozen nanometers. For this feature, this article first introduces several focusing technology, Obtained the advantages and disadvantages of various methods by comparing. Then get the accuracy of dual-grating focusing method through theoretical calculation. And the dual-grating focusing method based on photoelastic modulation is divided into coarse focusing and precise focusing method to analyze, establishing image processing model of coarse focusing and photoelastic modulation model of accurate focusing. Finally, focusing algorithm is simulated with MATLAB. In conclusion dual-grating focusing method shows high precision, high efficiency and non-contact measurement of the focal plane, meeting the demands of focusing in 193nm projection lithography.
Kal, Elmar; van den Brink, Henrieke; Houdijk, Han; van der Kamp, John; Goossens, Paulien Helena; van Bennekom, Coen; Scherder, Erik
2018-05-01
People without neurological impairments show superior motor learning when they focus on movement effects (external focus) rather than on movement execution itself (internal focus). Despite its potential for neurorehabilitation, it remains unclear to what extent external focus strategies are currently incorporated in rehabilitation post-stroke. Therefore, we observed how physical therapists use attentional focus when treating gait of rehabilitating patients with stroke. Twenty physical therapist-patient couples from six rehabilitation centers participated. Per couple, one regular gait-training session was video-recorded. Therapists' statements were classified using a standardized scoring method to determine the relative proportion of internally and externally focused instructions/feedback. Also, we explored associations between therapists' use of external/internal focus strategies and patients' focus preference, length of stay, mobility, and cognition. Therapists' instructions were generally more external while feedback was more internal. Therapists used relatively more externally focused statements for patients with a longer length of stay (B = -0.239, p = 0.013) and for patients who had a stronger internal focus preference (B = -0.930, p = 0.035). Physical therapists used more external focus instructions, but more internally focused feedback. Also, they seem to adapt their attentional focus use to patients' focus preference and rehabilitation phase. Future research may determine how these factors influence the effectiveness of different attentional foci for motor learning post-stroke. IMPLICATIONS FOR REHABILITATION Physical therapists use a balanced mix of internal focus and external focus instructions and feedback when treating gait of stroke patients. Therapists predominantly used an external focus for patients in later rehabilitation phases, and for patients with stronger internal focus preferences, possibly in an attempt to stimulate more automatic control of movement in these patients. Future research should further explore how a patients' focus preference and rehabilitation phase influence the effectiveness of different focus strategies. Awaiting further research, we recommend that therapists use both attentional focus strategies, and explore per patient which focus works best on a trial-and-error basis.
Near-field flat focusing mirrors
NASA Astrophysics Data System (ADS)
Cheng, Yu-Chieh; Staliunas, Kestutis
2018-03-01
This article reviews recent progress towards the design of near-field flat focusing mirrors, focusing/imaging light patterns in reflection. An important feature of such flat focusing mirrors is their transverse invariance, as they do not possess any optical axis. We start with a review of the physical background to the different focusing mechanisms of near- and far-field focusing. These near-field focusing devices like flat lenses and the reviewed near-field focusing mirrors can implement planar focusing devices without any optical axis. In contrast, various types of far-field planar focusing devices, such as high-contrast gratings and metasurfaces, unavoidably break the transverse invariance due to their radially symmetrical structures. The particular realizations of near-field flat focusing mirrors including Bragg-like dielectric mirrors and dielectric subwavelength gratings are the main subjects of the review. The first flat focusing mirror was demonstrated with a chirped mirror and was shown to manage an angular dispersion for beam focusing, similar to the management of chromatic dispersion for pulse compression. Furthermore, the reviewed optimized chirped mirror demonstrated a long near-field focal length, hardly achieved by a flat lens or a planar hyperlens. Two more different configurations of dielectric subwavelength gratings that focus a light beam at normal or oblique incidence are also reviewed. We also summarize and compare focusing performance, limitations, and future perspectives between the reviewed flat focusing mirrors and other planar focusing devices including a flat lens with a negative-index material, a planar hyperlens, a high-contrast grating, and a metasurface.
Simulation of ultrasonic focus aberration and correction through human tissue.
Tabei, Makoto; Mast, T Douglas; Waag, Robert C
2003-02-01
Ultrasonic focusing in two dimensions has been investigated by calculating the propagation of ultrasonic pulses through cross-sectional models of human abdominal wall and breast. Propagation calculations used a full-wave k-space method that accounts for spatial variations in density, sound speed, and frequency-dependent absorption and includes perfectly matched layer absorbing boundary conditions. To obtain a distorted receive wavefront, propagation from a point source through the tissue path was computed. Receive focusing used an angular spectrum method. Transmit focusing was accomplished by propagating a pressure wavefront from a virtual array through the tissue path. As well as uncompensated focusing, focusing that employed time-shift compensation and time-shift compensation after backpropagation was investigated in both transmit and receive and time reversal was investigated for transmit focusing in addition. The results indicate, consistent with measurements, that breast causes greater focus degradation than abdominal wall. The investigated compensation methods corrected the receive focus better than the transmit focus. Time-shift compensation after backpropagation improved the focus from that obtained using time-shift compensation alone but the improvement was less in transmit focusing than in receive focusing. Transmit focusing by time reversal resulted in lower sidelobes but larger mainlobes than the other investigated transmit focus compensation methods.
Coleman, Sulamunn R M; Zawadzki, Matthew J; Heron, Kristin E; Vartanian, Lenny R; Smyth, Joshua M
2016-01-01
This study examined whether self-focused and other-focused resiliency help explain how early family adversity relates to perceived stress, subjective health, and health behaviors in college women. Female students (N = 795) participated between October 2009 and May 2010. Participants completed self-report measures of early family adversity, self-focused (self-esteem, personal growth initiative) and other-focused (perceived social support, gratitude) resiliency, stress, subjective health, and health behaviors. Using structural equation modeling, self-focused resiliency associated with less stress, better subjective health, more sleep, less smoking, and less weekend alcohol consumption. Other-focused resiliency associated with more exercise, greater stress, and more weekend alcohol consumption. Early family adversity was indirectly related to all health outcomes, except smoking, via self-focused and other-focused resiliency. Self-focused and other-focused resiliency represent plausible mechanisms through which early family adversity relates to stress and health in college women. This highlights areas for future research in disease prevention and management.
Five focus strategies to organize health care delivery.
Peltokorpi, Antti; Linna, Miika; Malmström, Tomi; Torkki, Paulus; Lillrank, Paul Martin
2016-01-01
The focused factory is one of the concepts that decision-makers have adopted for improving health care delivery. However, disorganized definitions of focus have led to findings that cannot be utilized systematically. The purpose of this paper is to discuss strategic options to focus health care operations. First the literature on focus in health care is reviewed revealing conceptual challenges. Second, a definition of focus in terms of demand and requisite variety is defined, and the mechanisms of focus are explicated. A classification of five focus strategies that follow the original idea to reduce variety in products and markets is presented. Finally, the paper examines managerial possibilities linked to the focus strategies. The paper proposes a framework of five customer-oriented focus strategies which aim at reducing variety in different characteristics of care pathways: population; urgency and severity; illnesses and symptoms; care practices and processes; and care outcomes. Empirical research is needed to evaluate the costs and benefits of the five strategies and about system-level effects of focused units on competition and coordination. Focus is an enabling condition that needs to be exploited using specific demand and supply management practices. It is essential to understand how focus mechanisms differ between strategies, and to select focus that fits with organization's strategy and key performance indicators. Compared to previous more resource-oriented approaches, this study provides theoretically solid and practically relevant customer-oriented framework for focusing in health care.
Sassenrath, Claudia; Sassenberg, Kai; Ray, Devin G; Scheiter, Katharina; Jarodzka, Halszka
2014-01-01
Two studies examined an unexplored motivational determinant of facial emotion recognition: observer regulatory focus. It was predicted that a promotion focus would enhance facial emotion recognition relative to a prevention focus because the attentional strategies associated with promotion focus enhance performance on well-learned or innate tasks - such as facial emotion recognition. In Study 1, a promotion or a prevention focus was experimentally induced and better facial emotion recognition was observed in a promotion focus compared to a prevention focus. In Study 2, individual differences in chronic regulatory focus were assessed and attention allocation was measured using eye tracking during the facial emotion recognition task. Results indicated that the positive relation between a promotion focus and facial emotion recognition is mediated by shorter fixation duration on the face which reflects a pattern of attention allocation matched to the eager strategy in a promotion focus (i.e., striving to make hits). A prevention focus did not have an impact neither on perceptual processing nor on facial emotion recognition. Taken together, these findings demonstrate important mechanisms and consequences of observer motivational orientation for facial emotion recognition.
MRT letter: Guided filtering of image focus volume for 3D shape recovery of microscopic objects.
Mahmood, Muhammad Tariq
2014-12-01
In this letter, a shape from focus (SFF) method is proposed that utilizes the guided image filtering to enhance the image focus volume efficiently. First, image focus volume is computed using a conventional focus measure. Then each layer of image focus volume is filtered using guided filtering. In this work, the all-in-focus image, which can be obtained from the initial focus volume, is used as guidance image. Finally, improved depth map is obtained from the filtered image focus volume by maximizing the focus measure along the optical axis. The proposed SFF method is efficient and provides better depth maps. The improved performance is highlighted by conducting several experiments using image sequences of simulated and real microscopic objects. The comparative analysis demonstrates the effectiveness of the proposed SFF method. © 2014 Wiley Periodicals, Inc.
MR-guided Focused Ultrasound for Uterine Fibroids
... Professions Site Index A-Z MR-guided Focused Ultrasound for Uterine Fibroids Magnetic Resonance-guided Focused Ultrasound ( ... are the limitations of MRgFUS? What is Focused Ultrasound of Uterine Fibroids? Magnetic Resonance-guided Focused Ultrasound ( ...
NASA Astrophysics Data System (ADS)
Doskolovich, L. L.; Kazanskiy, N. L.; Kharitonov, S. I.; Uspleniev, G. V.
A new method is investigated for synthesis of computer-generated optical elements: focusators that are able to focus the radial-symmetrical laser beam into complex focal contours, in particular into alphanumeric symbols. The method is based on decomposition of the focal contour into segments of straight lines and semi-circles, following corresponding spacing out of the focusator on elementary segments (concentric rings or sectors) and solution of the inverse task of focusing from focusator segments into corresponding elements of the focal contour. The results of numerical computing of the field from synthesized focusators into the letters are presented. The theoretical efficiency of the focusators discussed is no less than 85%. The amplitude masks and the results of operational studies of synthesized focusators are presented.
The effects of attentional focus in the preparation and execution of a standing long jump.
Becker, Kevin A; Fairbrother, Jeffrey T; Couvillion, Kaylee F
2018-04-03
Attentional focus research suggests an external focus leads to improved motor performance compared to an internal focus (Wulf in Int Rev Sport Exerc Psychol 6:77-104, 2013), but skilled athletes often report using an internal focus (Fairbrother et al., Front Psychol 7:1028, 2016) and sometimes shifting between different foci in the preparation and execution phases of performance (Bernier et al. in J Appl Sport Psychol 23:326-341, 2011; Bernier et al. in Sport Psychol 30:256-266, 2016). To date, focus shifts have been unexplored in experimental research, thus the purpose of this study was to determine the effect of shifting focus between the preparation and execution phases of a standing long jump. Participants (N = 29) completed two jumps in a control condition (CON), followed by two jumps in four experimental conditions presented in a counterbalanced order. Conditions included using an external focus (EF) and internal focus (IF) in both preparation and execution of the skill, as well as shifting from an internal focus in preparation to an external focus in execution (ITE), and an external focus in preparation to an internal focus in execution (ETI). Jump distance was analyzed with a repeated measures ANOVA. The main effect of condition was significant, p < .001, with EF producing longer jumps than all other conditions (p's < 0.05). ITE also generated farther jumps than IF and CON (p's < 0.05). The superiority of the EF and ITE conditions suggests that the focus employed in execution has the strongest impact on performance. Additionally, if an internal focus must be used in preparation, the performance decrement can be ameliorated by shifting to an external focus during execution.
Fast auto-focus scheme based on optical defocus fitting model
NASA Astrophysics Data System (ADS)
Wang, Yeru; Feng, Huajun; Xu, Zhihai; Li, Qi; Chen, Yueting; Cen, Min
2018-04-01
An optical defocus fitting model-based (ODFM) auto-focus scheme is proposed. Considering the basic optical defocus principle, the optical defocus fitting model is derived to approximate the potential-focus position. By this accurate modelling, the proposed auto-focus scheme can make the stepping motor approach the focal plane more accurately and rapidly. Two fitting positions are first determined for an arbitrary initial stepping motor position. Three images (initial image and two fitting images) at these positions are then collected to estimate the potential-focus position based on the proposed ODFM method. Around the estimated potential-focus position, two reference images are recorded. The auto-focus procedure is then completed by processing these two reference images and the potential-focus image to confirm the in-focus position using a contrast based method. Experimental results prove that the proposed scheme can complete auto-focus within only 5 to 7 steps with good performance even under low-light condition.
Focus groups: a useful tool for curriculum evaluation.
Frasier, P Y; Slatt, L; Kowlowitz, V; Kollisch, D O; Mintzer, M
1997-01-01
Focus group interviews have been used extensively in health services program planning, health education, and curriculum planning. However, with the exception of a few reports describing the use of focus groups for a basic science course evaluation and a clerkship's impact on medical students, the potential of focus groups as a tool for curriculum evaluation has not been explored. Focus groups are a valid stand-alone evaluation process, but they are most often used in combination with other quantitative and qualitative methods. Focus groups rely heavily on group interaction, combining elements of individual interviews and participant observation. This article compares the focus group interview with both quantitative and qualitative methods; discusses when to use focus group interviews; outlines a protocol for conducting focus groups, including a comparison of various styles of qualitative data analysis; and offers a case study, in which focus groups evaluated the effectiveness of a pilot preclinical curriculum.
Kal, E. C.; van der Kamp, J.; Houdijk, H.; Groet, E.; van Bennekom, C. A. M.; Scherder, E. J. A.
2015-01-01
Dual-task performance is often impaired after stroke. This may be resolved by enhancing patients’ automaticity of movement. This study sets out to test the constrained action hypothesis, which holds that automaticity of movement is enhanced by triggering an external focus (on movement effects), rather than an internal focus (on movement execution). Thirty-nine individuals with chronic, unilateral stroke performed a one-leg-stepping task with both legs in single- and dual-task conditions. Attentional focus was manipulated with instructions. Motor performance (movement speed), movement automaticity (fluency of movement), and dual-task performance (dual-task costs) were assessed. The effects of focus on movement speed, single- and dual-task movement fluency, and dual-task costs were analysed with generalized estimating equations. Results showed that, overall, single-task performance was unaffected by focus (p = .341). Regarding movement fluency, no main effects of focus were found in single- or dual-task conditions (p’s ≥ .13). However, focus by leg interactions suggested that an external focus reduced movement fluency of the paretic leg compared to an internal focus (single-task conditions: p = .068; dual-task conditions: p = .084). An external focus also tended to result in inferior dual-task performance (β = -2.38, p = .065). Finally, a near-significant interaction (β = 2.36, p = .055) suggested that dual-task performance was more constrained by patients’ attentional capacity in external focus conditions. We conclude that, compared to an internal focus, an external focus did not result in more automated movements in chronic stroke patients. Contrary to expectations, trends were found for enhanced automaticity with an internal focus. These findings might be due to patients’ strong preference to use an internal focus in daily life. Future work needs to establish the more permanent effects of learning with different attentional foci on re-automating motor control after stroke. PMID:26317437
Enhancing the learning of sport skills through external-focus feedback.
Wulf, Gabriele; McConnel, Nathan; Gärtner, Matthias; Schwarz, Andreas
2002-06-01
The authors examined how the effectiveness of feedback for the learning of complex motor skills is affected by the focus of attention it induces. The feedback referred specifically either to body movements (internal focus) or to movement effects (external focus). In Experiment 1, groups of novices and advanced volleyball players (N = 48) practiced "tennis" serves under internal-focus or external-focus feedback conditions in a 2 (expertise) x 2 (feedback type) design. Type of feedback did not differentially affect movement quality, but external-focus feedback resulted in greater accuracy of the serves than internal-focus feedback during both practice and retention, independent of the level of expertise. In Experiment 2, the effects of relative feedback frequency as a function of attentional focus were examined. A 2 (feedback frequency: 100% vs. 33%) x 2 (feedback type) design was used. Experienced soccer players (N = 52) were required to shoot lofted passes at a target. External-focus feedback resulted in greater accuracy than internal-focus feedback did. In addition, reduced feedback frequency was beneficial under internal-focus feedback conditions, whereas 100% and 33% feedback were equally effective under external-focus conditions. The results demonstrate the effectiveness of effect-related, as opposed to movement-related, feedback and also suggest that there is a need to revise current views regarding the role of feedback for motor learning.
Focus group discussion in built environment qualitative research practice
NASA Astrophysics Data System (ADS)
Omar, D.
2018-02-01
Focus groups discussion is a useful way in built environment for qualitative research practice. Drawing upon recent reviews of focus group discussion and examples of how focus group discussions have been used by researchers and educators, this paper provides what actually happens in focus group discussion as practiced. There is difference between group of people and topic of interest. This article examines the focus group discussions as practiced in built environment. Thus, there is broad form of focus group discussions as practiced in built environment and the applications are varied.
van Abswoude, Femke; Nuijen, Nienke B; van der Kamp, John; Steenbergen, Bert
2018-06-01
A large pool of evidence supports the beneficial effect of an external focus of attention on motor skill performance in adults. In children, this effect has been studied less and results are inconclusive. Importantly, individual differences are often not taken into account. We investigated the role of working memory, conscious motor control, and task-specific focus preferences on performance with an internal and external focus of attention in children. Twenty-five children practiced a golf putting task in both an internal focus condition and external focus condition. Performance was defined as the average distance toward the hole in 3 blocks of 10 trials. Task-specific focus preference was determined by asking how much effort it took to apply the instruction in each condition. In addition, working memory capacity and conscious motor control were assessed. Children improved performance in both the internal focus condition and external focus condition (ŋ p 2 = .47), with no difference between conditions (ŋ p 2 = .01). Task-specific focus preference was the only factor moderately related to the difference between performance with an internal focus and performance with an external focus (r = .56), indicating better performance for the preferred instruction in Block 3. Children can benefit from instruction with both an internal and external focus of attention to improve short-term motor performance. Individual, task-specific focus preference influenced the effect of the instructions, with children performing better with their preferred focus. The results highlight that individual differences are a key factor in the effectiveness in children's motor performance. The precise mechanisms underpinning this effect warrant further research.
Phase-shifting point diffraction interferometer focus-aid enhanced mask
Naulleau, Patrick
2000-01-01
A phase-shifting point diffraction interferometer system (PS/PDI) employing a PS/PDI mask that includes a PDI focus aid is provided. The PDI focus aid mask includes a large or secondary reference pinhole that is slightly displaced from the true or primary reference pinhole. The secondary pinhole provides a larger capture tolerance for interferometrically performing fine focus. With the focus-aid enhanced mask, conventional methods such as the knife-edge test can be used to perform an initial (or rough) focus and the secondary (large) pinhole is used to perform interferometric fine focus. Once the system is well focused, high accuracy interferometry can be performed using the primary (small) pinhole.
Vaughn, Leigh Ann
2017-03-01
This article introduces the need-support model, which proposes that regulatory focus can affect subjective support for the needs proposed by self-determination theory (autonomy, competence, and relatedness), and support of these needs can affect subjective labeling of experiences as promotion-focused and prevention-focused. Three studies tested these hypotheses ( N = 2,114). Study 1 found that people recall more need support in promotion-focused experiences than in prevention-focused experiences, and need support in their day yesterday (with no particular regulatory focus) fell in between. Study 2 found that experiences of higher need support were more likely to be labeled as promotion-focused rather than prevention-focused, and that each need accounted for distinct variance in the labeling of experiences. Study 3 varied regulatory focus within a performance task and found that participants in the promotion condition engaged in need-support inflation, whereas participants in the prevention condition engaged in need-support deflation. Directions for future research are discussed.
Design of a new type synchronous focusing mechanism
NASA Astrophysics Data System (ADS)
Zhang, Jintao; Tan, Ruijun; Chen, Zhou; Zhang, Yongqi; Fu, Panlong; Qu, Yachen
2018-05-01
Aiming at the dual channel telescopic imaging system composed of infrared imaging system, low-light-level imaging system and image fusion module, In the fusion of low-light-level images and infrared images, it is obvious that using clear source images is easier to obtain high definition fused images. When the target is imaged at 15m to infinity, focusing is needed to ensure the imaging quality of the dual channel imaging system; therefore, a new type of synchronous focusing mechanism is designed. The synchronous focusing mechanism realizes the focusing function through the synchronous translational imaging devices, mainly including the structure of the screw rod nut, the shaft hole coordination structure and the spring steel ball eliminating clearance structure, etc. Starting from the synchronous focusing function of two imaging devices, the structure characteristics of the synchronous focusing mechanism are introduced in detail, and the focusing range is analyzed. The experimental results show that the synchronous focusing mechanism has the advantages of ingenious design, high focusing accuracy and stable and reliable operation.
2012-04-01
approach uses high intensity focused ultrasound ( HIFU ) and heat shock/ligand-dependent gene switches. Focused ultrasound generates localized...vasculature and bone. The approach uses high intensity focused ultrasound ( HIFU ) and heat shock/ligand-dependent gene switches. Focused ultrasound ...regeneration. Biomedical applications of high intensity focused ultrasound ( HIFU ) have revolved primarily around the mechanical and thermal ablation of
Farino, A.J.; Montague, S.; Sniegowski, J.J.; Smith, J.H.; McWhorter, P.J.
1998-07-21
A method is disclosed for photolithographically defining device features up to the resolution limit of an auto-focusing projection stepper when the device features are to be formed in a wafer cavity at a depth exceeding the depth of focus of the stepper. The method uses a focusing cavity located in a die field at the position of a focusing light beam from the auto-focusing projection stepper, with the focusing cavity being of the same depth as one or more adjacent cavities wherein a semiconductor device is to be formed. The focusing cavity provides a bottom surface for referencing the focusing light beam and focusing the stepper at a predetermined depth below the surface of the wafer, whereat the device features are to be defined. As material layers are deposited in each device cavity to build up a semiconductor structure such as a microelectromechanical system (MEMS) device, the same material layers are deposited in the focusing cavity, raising the bottom surface and re-focusing the stepper for accurately defining additional device features in each succeeding material layer. The method is especially applicable for forming MEMS devices within a cavity or trench and integrating the MEMS devices with electronic circuitry fabricated on the wafer surface. 15 figs.
Farino, Anthony J.; Montague, Stephen; Sniegowski, Jeffry J.; Smith, James H.; McWhorter, Paul J.
1998-01-01
A method is disclosed for photolithographically defining device features up to the resolution limit of an auto-focusing projection stepper when the device features are to be formed in a wafer cavity at a depth exceeding the depth of focus of the stepper. The method uses a focusing cavity located in a die field at the position of a focusing light beam from the auto-focusing projection stepper, with the focusing cavity being of the same depth as one or more adjacent cavities wherein a semiconductor device is to be formed. The focusing cavity provides a bottom surface for referencing the focusing light beam and focusing the stepper at a predetermined depth below the surface of the wafer, whereat the device features are to be defined. As material layers are deposited in each device cavity to build up a semiconductor structure such as a microelectromechanical system (MEMS) device, the same material layers are deposited in the focusing cavity, raising the bottom surface and re-focusing the stepper for accurately defining additional device features in each succeeding material layer. The method is especially applicable for forming MEMS devices within a cavity or trench and integrating the MEMS devices with electronic circuitry fabricated on the wafer surface.
Instructions to Adopt an External Focus Enhance Muscular Endurance
ERIC Educational Resources Information Center
Marchant, David C.; Greig, Matt; Bullough, Jonathan; Hitchen, Daniel
2011-01-01
The influence of internal (movement focus) and external (outcome focus) attentional-focusing instructions on muscular endurance were investigated using three exercise protocols with experienced exercisers. Twenty-three participants completed a maximal repetition, assisted bench-press test on a Smith's machine. An external focus of attention…
Stress Management in the Health Care Setting: Matching Interventions with Patient Coping Styles.
ERIC Educational Resources Information Center
Martelli, Michael F.; And Others
1987-01-01
Prospective preprosthetic oral surgery patients were presented with a problem-focused, emotion-focused, or mixed-focus stress management intervention. The mixed-focus intervention produced the best overall response to surgery; the emotion-focused intervention produced the lowest adjustment levels. Better adjustment and satisfaction and lower…
Incidental Focus on Form and Second Language Learning
ERIC Educational Resources Information Center
Loewen, Shawn
2005-01-01
Incidental focus on form overtly draws learners' attention to linguistic items as they arise spontaneously--without prior planning--in meaning-focused interaction. This study examined the effectiveness of incidental focus on form in promoting second language (L2) learning. Seventeen hours of naturally occurring, meaning-focused L2 lessons were…
21 CFR 878.4590 - Focused ultrasound stimulator system for aesthetic use.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Focused ultrasound stimulator system for aesthetic....4590 Focused ultrasound stimulator system for aesthetic use. (a) Identification. A Focused Ultrasound Stimulator System for Aesthetic Use is a device using focused ultrasound to produce localized, mechanical...
21 CFR 878.4590 - Focused ultrasound stimulator system for aesthetic use.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Focused ultrasound stimulator system for aesthetic....4590 Focused ultrasound stimulator system for aesthetic use. (a) Identification. A Focused Ultrasound Stimulator System for Aesthetic Use is a device using focused ultrasound to produce localized, mechanical...
21 CFR 878.4590 - Focused ultrasound stimulator system for aesthetic use.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Focused ultrasound stimulator system for aesthetic....4590 Focused ultrasound stimulator system for aesthetic use. (a) Identification. A Focused Ultrasound Stimulator System for Aesthetic Use is a device using focused ultrasound to produce localized, mechanical...
Design and Construction of a Dense Plasma Focus Device
1976-10-01
This paper deals with the design of a dense plasma focus device as an engineering project. Essentially this approach can be summarized as follows...First, an introduction dealing with a general discussion of plasma devices focusing on the role of a dense plasma focus device as a useful tool in...future research; second, an explanation of the operation of the dense plasma focus ; third, a general design discussion of the dense plasma focus device
A Tikhonov Regularization Scheme for Focus Rotations with Focused Ultrasound Phased Arrays
Hughes, Alec; Hynynen, Kullervo
2016-01-01
Phased arrays have a wide range of applications in focused ultrasound therapy. By using an array of individually-driven transducer elements, it is possible to steer a focus through space electronically and compensate for acoustically heterogeneous media with phase delays. In this paper, the concept of focusing an ultrasound phased array is expanded to include a method to control the orientation of the focus using a Tikhonov regularization scheme. It is then shown that the Tikhonov regularization parameter used to solve the ill-posed focus rotation problem plays an important role in the balance between quality focusing and array efficiency. Finally, the technique is applied to the synthesis of multiple foci, showing that this method allows for multiple independent spatial rotations. PMID:27913323
A Tikhonov Regularization Scheme for Focus Rotations With Focused Ultrasound-Phased Arrays.
Hughes, Alec; Hynynen, Kullervo
2016-12-01
Phased arrays have a wide range of applications in focused ultrasound therapy. By using an array of individually driven transducer elements, it is possible to steer a focus through space electronically and compensate for acoustically heterogeneous media with phase delays. In this paper, the concept of focusing an ultrasound-phased array is expanded to include a method to control the orientation of the focus using a Tikhonov regularization scheme. It is then shown that the Tikhonov regularization parameter used to solve the ill-posed focus rotation problem plays an important role in the balance between quality focusing and array efficiency. Finally, the technique is applied to the synthesis of multiple foci, showing that this method allows for multiple independent spatial rotations.
[The relationship among self-focused attention, depression, and anxiety].
Tanaka, Seiichi; Sato, Hiroshi; Sakai, Motohiro; Sakano, Yuji
2007-10-01
Self-focused attention is considered to be a cognitive characteristic of depression. However, some articles report that self-focused attention is also related to anxiety. This study examines the differential relationships of self-focused attention to depression and anxiety. The Preoccupation Scale, Self-rating Depression Scale, and State-Trait Anxiety Inventory T-Form were administered to 454 undergraduate students. The results showed a partial correlation between self-focused attention and anxiety that was significant while controlling for depression, but the partial correlation between self-focused attention and depression was not significant while controlling for anxiety. In addition, the results of an analysis of covariance structure revealed that self-focused attention was related to anxiety, and the relationship between self-focused attention and depression was due to the mediating effect of anxiety. Therefore, it was suggested that self-focused attention appears to be a significant component of cognitive operations for anxiety, but not for depression.
NASA Astrophysics Data System (ADS)
Zhang, J.; Li, M.; Li, W. H.; Alici, G.
2013-08-01
The focusing of particles has a variety of applications in industry and biomedicine, including wastewater purification, fermentation filtration, and pathogen detection in flow cytometry, etc. In this paper a novel inertial microfluidic device using two secondary flows to focus particles is presented. The geometry of the proposed microfluidic channel is a simple straight channel with asymmetrically patterned triangular expansion-contraction cavity arrays. Three different focusing patterns were observed under different flow conditions: (1) a single focusing streak on the cavity side; (2) double focusing streaks on both sides; (3) half of the particles were focused on the opposite side of the cavity, while the other particles were trapped by a horizontal vortex in the cavity. The focusing performance was studied comprehensively up to flow rates of 700 µl min-1. The focusing mechanism was investigated by analysing the balance of forces between the inertial lift forces and secondary flow drag in the cross section. The influence of particle size and cavity geometry on the focusing performance was also studied. The experimental results showed that more precise focusing could be obtained with large particles, some of which even showed a single-particle focusing streak in the horizontal plane. Meanwhile, the focusing patterns and their working conditions could be adjusted by the geometry of the cavity. This novel inertial microfluidic device could offer a continuous, sheathless, and high-throughput performance, which can be potentially applied to high-speed flow cytometry or the extraction of blood cells.
Mullen, Richard; Faull, Andrea; Jones, Eleri S; Kingston, Kieran
2012-01-01
Previous studies have demonstrated that an external focus can enhance motor learning compared to an internal focus. The benefits of adopting an external focus are attributed to the use of less effortful automatic control processes, while an internal focus relies upon more effort-intensive consciously controlled processes. The aim of this study was to compare the effectiveness of a distal external focus with an internal focus in the acquisition of a simulated driving task and subsequent performance in a competitive condition designed to increase state anxiety. To provide further evidence for the automatic nature of externally controlled movements, the study included heart rate variability (HRV) as an index of mental effort. Sixteen participants completed eight blocks of four laps in either a distal external or internal focus condition, followed by two blocks of four laps in the competitive condition. During acquisition, the performance of both groups improved; however, the distal external focus group outperformed the internal focus group. The poorer performance of the internal focus group was accompanied by a larger reduction in HRV, indicating a greater investment of mental effort. In the competition condition, state anxiety increased, and for both groups, performance improved as a function of the increased anxiety. Increased heart rate and self-reported mental effort accompanied the performance improvement. The distal external focus group also outperformed the internal focus group across both neutral and competitive conditions and this more effective performance was again associated with lower levels of HRV. Overall, the results offer support for the suggestion that an external focus promotes a more automatic mode of functioning. In the competitive condition, both foci enhanced performance and while the improved performance may have been achieved at the expense of greater compensatory mental effort, this was not reflected in HRV scores.
Sharp-Focus Composite Microscope Imaging by Computer
NASA Technical Reports Server (NTRS)
Wall, R. J.
1983-01-01
Enhanced depth of focus aids medical analysis. Computer image-processing system synthesizes sharply-focused composite picture from series of photomicrographs of same object taken at different depths. Computer rejects blured parts of each photomicrograph. Remaining in focus portions form focused composite. System used to study alveolar lung tissue and has applications in medicine and physical sciences.
Observers' focus of attention in the simulation of self-perception.
Wegner, D M; Finstuen, K
1977-01-01
This research was designed to assess the effects of a manipulation of observers' focus of attention--from a focus on the actor to a focus on the actor's situation--upon observers' attributions of attitude to an actor in a simulation of a forced-compliance cognitive dissonance experiment. Observers induced through empathy instructions to focus attention on the actor's situation inferred less actor attitude positivity than did observers given no specific observational set. In addition, situation-focused observers inferred that the actor's attitude was directly related to reward magnitude, whereas actor-focused observers inferred that the actor's attitude was inversely related to reward magnitude. An extension of self-perception theory, offered as an interpretation of these and other results, suggested that motivation attribution made by actors and observers in dissonance and simulation studies are dependent on focus of attention. The attributions made by actor-focused observers simulate those of objectively self-aware actors and are based upon perceived intrinsic motivation; the attributions of situation-focused observers simulate those of subjectively self-aware actors and are based upon perceived extrinsic motivation.
Focused Ultrasound Surgery for Uterine Fibroids
... ultrasound surgery, your doctor may perform a pelvic magnetic resonance imaging (MRI) scan before treatment. Focused ultrasound surgery — also called magnetic resonance-guided focused ultrasound surgery or focused ultrasound ...
The focusing effect in backward Raman amplification in plasma
NASA Astrophysics Data System (ADS)
Li, Zhaoli; Peng, Hao; Zuo, Yanlei; Su, Jingxin; Yang, Suhui
2018-04-01
In this paper, the focusing effect on backward Raman amplification in plasma is investigated. A fluid model, used to simulate the backward Raman amplification and including the relativistic, ponderomotive, and thermal self-focusing and the mutual-focusing effect simultaneously, is proposed and investigated. The focusing effect is shown to severely distort the profile of the seed when the seed intensity was as high as 10 17 W/cm2. Reducing the plasma density can relax the focusing effect, but at the cost of decreasing the amplification efficiency. Changing the profile of the seed has a limited effect on mitigating the focusing effect. A Gaussian profile of the pump and a defocusing shape of the plasma density seem to be an effective way to mitigate the focusing effect without decreasing the amplification efficiency.
Veale, David; Miles, Sarah; Valiallah, Natasha; Butt, Saira; Anson, Martin; Eshkevari, Ertimiss; Gledhill, Lucinda J; Baldock, Emma
2016-09-01
Self-focused attention is hypothesized to be a maintenance factor in body dysmorphic disorder (BDD). The aim of this study was to use an experimental paradigm to test this hypothesis by studying the effect of self-focused attention during mirror-gazing on appearance dissatisfaction. An experimental group design was used, in which 173 women were randomly allocated to one of three conditions before mirror-gazing for 2 min: (a) external focus of attention, (b) self-focus of attention, and (c) self-focus of attention with a negative mood induction. After mirror-gazing, participants across all groups rated themselves as being more dissatisfied with their appearance. In both the self-focus conditions, there was an increase in sadness from pre to post mirror gazing, and there was a significant difference in focus of attention for participants in the self-focused, mood-induced group from pre to post manipulation, suggesting mood induction had more of an effect than focus of attention. (1) there was no condition involving an external focus with a negative mood induction, and (2) due to the level of information provided to patients on the nature of the task, we cannot rule out demand characteristics as an influencing factor on our results. Self-focused attention during mirror-gazing may act indirectly to increase appearance dissatisfaction via the effect of negative mood. Further studies are required to establish the relative contribution of self-focused attention and negative mood to increases in appearance dissatisfaction as a function of mirror-gazing. Copyright © 2016 Elsevier Ltd. All rights reserved.
Solution-focused premarital counseling: helping couples build a vision for their marriage.
Murray, Christine E; Murray, Thomas L
2004-07-01
This article outlines a solution-focused approach to premarital counseling. Solution-focused premarital counseling is a strength-based approach that focuses on a couple's resources to develop a shared vision for the marriage. Background information about premarital counseling and solution-focused therapy provide the framework for the development of intervention strategies that are grounded in the solution-focused approach. Solution-oriented interventions include solution-oriented questions, providing feedback, and the Couple's Resource Map, an original intervention that is described in this article.
1985-06-01
Research on this grant has focused on plasma focus experiments in the areas of particle beam generation and as a potential repetitive opening switch...as were scaling laws for the increase of electron energy and current with input energy. The potential of the plasma focus as an opening switch was...delay line technique. The observed frequencies were most consistent with the lower hybrid frequency. Keywords include: Dense Plasma Focus , Particle Beam Generation, Opening Switch, Load Experiments, Pulsed Power.
Parker, Stacey L; Laurie, Kaitlan R; Newton, Cameron J; Jimmieson, Nerina L
2014-12-01
This experiment examined whether trait regulatory focus moderates the effects of task control on stress reactions during a demanding work simulation. Regulatory focus describes two ways in which individuals self-regulate toward desired goals: promotion and prevention. As highly promotion-focused individuals are oriented toward growth and challenge, it was expected that they would show better adaptation to demanding work under high task control. In contrast, as highly prevention-focused individuals are oriented toward safety and responsibility they were expected to show better adaptation under low task control. Participants (N=110) completed a measure of trait regulatory focus and then three trials of a demanding inbox activity under either low, neutral, or high task control. Heart rate variability (HRV), affective reactions (anxiety & task dissatisfaction), and task performance were measured at each trial. As predicted, highly promotion-focused individuals found high (compared to neutral) task control stress-buffering for performance. Moreover, highly prevention-focused individuals found high (compared to low) task control stress-exacerbating for dissatisfaction. In addition, highly prevention-focused individuals found low task control stress-buffering for dissatisfaction, performance, and HRV. However, these effects of low task control for highly prevention-focused individuals depended on their promotion focus. Crown Copyright © 2014. Published by Elsevier B.V. All rights reserved.
Focus of Attention in Children's Motor Learning: Examining the Role of Age and Working Memory.
Brocken, J E A; Kal, E C; van der Kamp, J
2016-01-01
The authors investigated the relative effectiveness of different attentional focus instructions on motor learning in primary school children. In addition, we explored whether the effect of attentional focus on motor learning was influenced by children's age and verbal working memory capacity. Novice 8-9-year old children (n = 30) and 11-12-year-old children (n = 30) practiced a golf putting task. For each age group, half the participants received instructions to focus (internally) on the swing of their arm, while the other half was instructed to focus (externally) on the swing of the club. Children's verbal working memory capacity was assessed with the Automated Working Memory Assessment. Consistent with many reports on adult's motor learning, children in the external groups demonstrated greater improvements in putting accuracy than children who practiced with an internal focus. This effect was similar across age groups. Verbal working memory capacity was not found to be predictive of motor learning, neither for children in the internal focus groups nor for children in the external focus groups. In conclusion, primary school children's motor learning is enhanced by external focus instructions compared to internal focus instructions. The purported modulatory roles of children's working memory, attentional capacity, or focus preferences require further investigation.
Technology-enhanced focus groups as a component of instrument development.
Strout, Tania D; DiFazio, Rachel L; Vessey, Judith A
2017-06-22
Background Bullying is a critical public health problem and a screening tool for use in healthcare is needed. Focus groups are a common tool for generating qualitative data when developing an instrument and evidence suggests that technology-enhanced focus groups can be effective in simultaneously engaging participants from diverse settings. Aim To examine the use of technology-enhanced focus groups in generating an item pool to develop a youth-bullying screening tool. Discussion The authors explore methodological and ethical issues related to conducting technology-enhanced focus groups, drawing on their experience in developing a youth-bullying measure. They conducted qualitative focus groups with professionals from the front lines of bullying response and intervention. They describe the experience of conducting technology-enhanced focus group sessions, focusing on the methodological and ethical issues that researchers engaging in similar work may encounter. Challenges associated with this methodology include establishing rapport among participants, privacy concerns and limited non-verbal communication. Conclusion The use of technology-enhanced focus groups can be valuable in obtaining rich data from a wide variety of disciplines and contexts. Organising these focus groups was inexpensive and preferred by the study's participants. Implications for practice Researchers should consider using technology-enhanced focus groups to generate data to develop health-related measurement tools.
Performance of gymnastics skill benefits from an external focus of attention.
Abdollahipour, Reza; Wulf, Gabriele; Psotta, Rudolf; Palomo Nieto, Miriam
2015-01-01
The present study was designed to fill a gap in the literature on attentional focus and sports performance. Specifically, in contrast to most previous studies in which an external focus was directed at an implement, we used a gymnastics skill that did not involve the use of an implement. Furthermore, while most studies used only outcome measures of performance, we also assessed movement quality. Twelve-year-old gymnasts performed a maximum vertical jump with a 180-degree turn while airborne, with their hands crossing in front of their chest during the turn under three different focus conditions. Under the external focus condition, participants were asked to focus on the direction in which a tape marker, which was attached to their chest, was pointing after the turn. Under the internal focus condition, they were asked to focus on the direction in which their hands were pointing after the turn. Under the control condition, no focus instructions were given. The external focus condition resulted in both superior movement form and greater jump height than did the other two conditions, which produced comparable results. The present findings show that, similar to other tasks, the performance of form-based skills can be enhanced relatively easily by appropriate external focus instructions.
ERIC Educational Resources Information Center
Tajeddin, Zia; Daraee, Dina
2013-01-01
The present study investigated the effect of form-focused and non-form-focused tasks on EFL learners' vocabulary learning through written input. The form-focused task aimed to draw students' attention to the word itself through word recognition activities. Non-form-focused tasks were divided into (a) the comprehension question task, which required…
ERIC Educational Resources Information Center
Thomas-Stonell, Nancy L.; Oddson, Bruce; Robertson, Bernadette; Rosenbaum, Peter L.
2010-01-01
Aim: Our aim was to develop an outcome measure, called Focus on the Outcomes of Communication Under Six (FOCUS), that captures real-world changes in preschool children's communication. Conceptually grounded in the World Health Organization International Classification of Functioning, Disability and Health framework, the FOCUS items were derived…
... Describing and Focusing 3A. Focus On: Thinking About Design 4. Gathering and Using Data 4A. Focus On: ... Focus on Using Mixed Methods 5. Purpose Informs Design Other Evaluation Resources Multimedia Messages Agencies Working on ...
Improved telescope focus using only two focus images
NASA Astrophysics Data System (ADS)
Barrick, Gregory; Vermeulen, Tom; Thomas, James
2008-07-01
In an effort to reduce the amount of time spent focusing the telescope and to improve the quality of the focus, a new procedure has been investigated and implemented at the Canada-France-Hawaii Telescope (CFHT). The new procedure is based on a paper by Tokovinin and Heathcote and requires only two out-of-focus images to determine the best focus for the telescope. Using only two images provides a great time savings over the five or more images required for a standard through-focus sequence. In addition, it has been found that this method is significantly less sensitive to seeing variations than the traditional through-focus procedure, so the quality of the resulting focus is better. Finally, the new procedure relies on a second moment calculation and so is computationally easier and more robust than methods using a FWHM calculation. The new method has been implemented for WIRCam for the past 18 months, for MegaPrime for the past year, and has recently been implemented for ESPaDOnS.
Wong, Norman C H; Nisbett, Gwendelyn S; Harvell, Lindsey A
2017-04-01
This study utilizes Terror Management Theory (TMT) to examine differences between eliciting social death and physical death anxiety related to smoking, smoking attitudes, and quitting intent among college students. Moreover, an important TMT variable-self-esteem-was used as a moderator. A 2 × 3 between-subjects factorial design crossed smoking-based self-esteem (low, high) with mortality salience manipulation (health-focused, social-focused, control). Results suggest while both making health-focused salient and making social-focused mortality salient were effective at getting smokers to quit, there was less effect for health-focused mortality salience on those whose self-esteem is strongly tied to smoking. Effect of social-focused mortality salience was more pronounced among participants who highly linked self-esteem with smoking. For smokers with low smoking-based self-esteem, both health-focused and social-focused mortality salience were effective at motivating attitude change toward smoking and quitting intentions. Implications for smoking cessation ad design and TMT are discussed.
Knafl, Kathleen A; Deatrick, Janet A; Knafl, George J; Gallo, Agatha M; Grey, Margaret; Dixon, Jane
2013-01-01
Understanding patterns of family response to childhood chronic conditions provides a more comprehensive understanding of their influence on family and child functioning. In this paper, we report the results of a cluster analysis based on the six scales comprising the Family Management Measure (FaMM) and the resulting typology of family management. The sample of 575 parents (414 families) of children with diverse chronic conditions fell into four patterns of response (Family Focused, Somewhat Family Focused, Somewhat Condition Focused, Condition Focused) that differed in the extent family life was focused on usual family routines or the demands of condition management. Most (57%) families were in either the Family Focused or Somewhat Family Focused pattern. Patterns of family management were related significantly to family and child functioning, with families in the Family Focused and Somewhat Family Focused patterns demonstrating significantly better family and child functioning than families in the other two patterns. Copyright © 2013. Published by Elsevier Inc.
Ruan, Haowen; Brake, Joshua; Robinson, J. Elliott; Liu, Yan; Jang, Mooseok; Xiao, Cheng; Zhou, Chunyi; Gradinaru, Viviana; Yang, Changhuei
2017-01-01
Noninvasive light focusing deep inside living biological tissue has long been a goal in biomedical optics. However, the optical scattering of biological tissue prevents conventional optical systems from tightly focusing visible light beyond several hundred micrometers. The recently developed wavefront shaping technique time-reversed ultrasonically encoded (TRUE) focusing enables noninvasive light delivery to targeted locations beyond the optical diffusion limit. However, until now, TRUE focusing has only been demonstrated inside nonliving tissue samples. We present the first example of TRUE focusing in 2-mm-thick living brain tissue and demonstrate its application for optogenetic modulation of neural activity in 800-μm-thick acute mouse brain slices at a wavelength of 532 nm. We found that TRUE focusing enabled precise control of neuron firing and increased the spatial resolution of neuronal excitation fourfold when compared to conventional lens focusing. This work is an important step in the application of TRUE focusing for practical biomedical uses. PMID:29226248
... Describing and Focusing 3A. Focus On: Thinking About Design 4. Gathering and Using Data 4A. Focus On: ... Focus on Using Mixed Methods 5. Purpose Informs Design Other Evaluation Resources Multimedia Messages Agencies Working on ...
Broadband and flexible acoustic focusing by metafiber bundles
NASA Astrophysics Data System (ADS)
Sun, Hong-Xiang; Chen, Jia-He; Ge, Yong; Yuan, Shou-Qi; Liu, Xiao-Jun
2018-06-01
We report a broadband and flexible acoustic focusing through metafiber bundles in air, in which each metafiber consists of eight circular and narrow rectangular cavities. The fractional bandwidth of the acoustic focusing could reach about 0.2, which arises from the eigenmodes of the metafiber structure. Besides, owing to the flexible characteristic of the metafibers, the focus position can be manipulated by bending the metafiber bundles, and the metafiber bundles could bypass rigid scatterers inside the lens structure. More interestingly, the acoustic propagation and focusing directions can be changed by using a designed right-angled direction converter fabricated by the metafibers, and a waveform converter and a focusing lens of the cylindrical acoustic source are realized based on the metafiber bundles. The proposed focusing lens has the advantages of broad bandwidth, flexible structure, and high focusing performance, showing great potentials in versatile applications.
Intervention for the bereaved: gender differences in the efficacy of two counselling programmes.
Schut, H A; Stroebe, M S; van den Bout, J; de Keijser, J
1997-02-01
This article describes an investigation of emotion-focused versus problem-focused intervention for widowers (N = 23) and widowers (N = 23) who were suffering elevated levels of distress 11 months after their loss. They were randomly assigned to an intervention condition and improvement (on the General Health Questionnaire) was compared with non-intervention controls (N = 59). Two alternative hypotheses were considered: (1) men, since they focus less on their emotions, would benefit from problem-focused counselling, while women, focusing more on their emotions, would benefit from emotion-focused intervention; (2) each gender, having been comparatively unsuccessful in coping through these usual strategies, would benefit more from intervention directed towards the less familiar strategy. Results supported the second hypothesis: widowers benefited more from emotion-focused, widows from problem-focused interventions. Implications for supporting widows and widowers are discussed.
van Lankveld, Jacques; Bergh, Simone
2008-04-01
In this study we investigated the effects of state and trait aspects of self-focused attention on genital and subjective sexual arousal of sexually functional, healthy women during presentation of audiovisual erotic stimuli. Psychophysiological sexual response was measured as vaginal pulse amplitude using a vaginal photoplethysmograph. Experiential aspects of sexual arousal were measured both during stimulus presentation and retrospectively after stimulus offset. Trait level of sexual self-focus was measured with the Sexual Self-Consciousness Scale. State self-focus was induced by switching on a TV camera that pointed at the participant's face and upper torso. A manipulation check revealed that both groups experienced equally elevated levels of self-focused attention of their physical appearance. Induction of state self-focus per se did not affect genital responses, but an interaction effect of self-focus and participants' level of trait sexual self-focus was revealed. Compared with women with low scores on this trait, women with high scores exhibited smaller genital responses when state self-focus was induced. Both groups did not differ when no self-focus was induced. Increase of state self-focus did not affect subjective sexual arousal, but participants with a high level of trait sexual self-focus reported stronger subjective arousal, compared with those with low trait level. The results were discussed with reference to previous work in this field. Some implications for treatment of sexual arousal disorder were discussed.
Subwavelength dark hollow focus of spirally polarized axisymmetric Bessel-modulated Gaussian beam
NASA Astrophysics Data System (ADS)
Gao, X. M.; Zhan, Q. F.; Wang, Q.; Yun, M. J.; Guo, H. M.; Zhuang, S. L.
2011-09-01
Dark hollow focus plays an important role in many optical systems. In this paper, dark hollow focal shaping of spirally polarized axisymmetric Bessel-modulated Gaussian beam is investigated by vector diffraction theory in detail. Results show that the dark hollow focus can be altered considerably by beam parameter and spiral parameter that indicates polarization spiral degree. One dark hollow focus and two dark hollow foci pattern may occur for certain spiral parameter, and the transverse size of dark hollow focus can be less than the diffraction limit size of bright focus. In addition, there may also appear two triangle dark hollow foci that are connected by one dark line focus.
ERIC Educational Resources Information Center
Saeidi, Mahnaz; Zaferanieh, Elaheh; Shatery, Hafez
2012-01-01
This study investigated the effectiveness of three kinds of vocabulary instruction. Seventy learners in the classes of English for Specific Purposes (ESP) were divided into three different groups receiving different instructions: Focus on Form Instruction (FoF) (Dictogloss task), Focus on Meaning Instruction (FoM) (Reading and Discussion task),…
ERIC Educational Resources Information Center
Hasan, Md. Kamrul
2015-01-01
This work attempts to investigate the role of prosody in the syntax of focus in Bangla. The aim of this study is to show the intonation pattern of Bangla in emphasis and focus. In order to do that, the author has looked at the pattern of focus without-i/o as well as with the same. Do they really pose any different focus intonation pattern from…
Plasma Charge Current for Controlling and Monitoring Electron Beam Welding with Beam Oscillation
Trushnikov, Dmitriy; Belenkiy, Vladimir; Shchavlev, Valeriy; Piskunov, Anatoliy; Abdullin, Aleksandr; Mladenov, Georgy
2012-01-01
Electron beam welding (EBW) shows certain problems with the control of focus regime. The electron beam focus can be controlled in electron-beam welding based on the parameters of a secondary signal. In this case, the parameters like secondary emissions and focus coil current have extreme relationships. There are two values of focus coil current which provide equal value signal parameters. Therefore, adaptive systems of electron beam focus control use low-frequency scanning of focus, which substantially limits the operation speed of these systems and has a negative effect on weld joint quality. The purpose of this study is to develop a method for operational control of the electron beam focus during welding in the deep penetration mode. The method uses the plasma charge current signal as an additional informational parameter. This parameter allows identification of the electron beam focus regime in electron-beam welding without application of additional low-frequency scanning of focus. It can be used for working out operational electron beam control methods focusing exactly on the welding. In addition, use of this parameter allows one to observe the shape of the keyhole during the welding process. PMID:23242276
Regulatory Focus Affects Physician Risk Tolerance
Veazie, Peter J.; McIntosh, Scott; Chapman, Benjamin P.; Dolan, James G.
2014-01-01
Risk tolerance is a source of variation in physician decision-making. This variation, if independent of clinical concerns, can result in mistaken utilization of health services. To address such problems, it will be helpful to identify nonclinical factors of risk tolerance, particularly those amendable to intervention – regulatory focus theory suggests such a factor. This study tested whether regulatory focus affects risk tolerance among primary care physicians. Twenty-seven primary care physicians were assigned to promotion-focused or prevention-focused manipulations and compared on the Risk Taking Attitudes in Medical Decision Making scale using a randomization test. Results provide evidence that physicians assigned to the promotion-focus manipulation adopted an attitude of greater risk tolerance than the physicians assigned to the prevention-focused manipulation (P=0.01). The Cohen’s d statistic was conventionally large at 0.92. Results imply that situational regulatory focus in primary care physicians affects risk tolerance and may thereby be a nonclinical source of practice variation. Results also provide marginal evidence that chronic regulatory focus is associated with risk tolerance (P=0.05), but the mechanism remains unclear. Research and intervention targeting physician risk tolerance may benefit by considering situational regulatory focus as an explanatory factor. PMID:25431799
Plasma charge current for controlling and monitoring electron beam welding with beam oscillation.
Trushnikov, Dmitriy; Belenkiy, Vladimir; Shchavlev, Valeriy; Piskunov, Anatoliy; Abdullin, Aleksandr; Mladenov, Georgy
2012-12-14
Electron beam welding (EBW) shows certain problems with the control of focus regime. The electron beam focus can be controlled in electron-beam welding based on the parameters of a secondary signal. In this case, the parameters like secondary emissions and focus coil current have extreme relationships. There are two values of focus coil current which provide equal value signal parameters. Therefore, adaptive systems of electron beam focus control use low-frequency scanning of focus, which substantially limits the operation speed of these systems and has a negative effect on weld joint quality. The purpose of this study is to develop a method for operational control of the electron beam focus during welding in the deep penetration mode. The method uses the plasma charge current signal as an additional informational parameter. This parameter allows identification of the electron beam focus regime in electron-beam welding without application of additional low-frequency scanning of focus. It can be used for working out operational electron beam control methods focusing exactly on the welding. In addition, use of this parameter allows one to observe the shape of the keyhole during the welding process.
Effect of different external attention of focus instruction on learning of golf putting skill.
Shafizadeh, Mohsen; McMorris, Terry; Sproule, John
2011-10-01
The effect of different sources of external attentional focus on learning a motor skill was assessed in the present study. 30 students (12 men, 18 women) participated voluntarily and were divided, according to type of external focus, into target, club swing, and target-club swing groups. The task was a golf putting skill. The target focus group attended to the target (hole), the club swing focus group attended to the execution of the club's swing, and the target-club swing focus group attended to both. All participants performed 50 trials of the putting skill in the acquisition phase and 10 trials in the 24-hr. delayed retention phase. The dependent variable was the error in the putting skill measured as the distance from the hole to the ball after each strike. Results showed the target-club swing focus group had better scores in the acquisition and retention phases than the other groups. It was concluded that external focus instruction helped the learners to integrate target cue with action cue and is more effective in skill learning than other external-focus instructions. These results support the claims of ecological psychology theorists concerning the effects of external focus of attention.
Adaptive photoacoustic imaging using the Mallart-Fink focusing factor
NASA Astrophysics Data System (ADS)
Li, Meng-Lin
2008-02-01
Focusing errors caused by sound velocity heterogeneities widen the mainlobe and elevate the sidelobes, thus degrading both spatial and contrast resolutions in photoacoustic imaging. We propose an adaptive array-based photoacoustic imaging technique that uses the Mallart-Fink (MF) focusing factor weighting to reduce the effect of such focusing errors. The definition of the MF focusing factor indicates that the MF focusing factor at the main lobe of the point-spread function is high (close to 1, without speckle noise being present, which is the case in photoacoustic imaging), whereas it is low at the sidelobes. Based on this property, the elevated sidelobes caused by sound velocity heterogeneities in the tissue can be suppressed after being multiplied by the corresponding map of the MF focusing factor on each imaging point; thus the focusing quality can be improved. This technique makes no assumption of sources of focusing errors and directly suppresses the unwanted sidelobe contributions. Numerical experiments with near field phase screen and displaced phase screen models were performed here to verify the proposed adaptive weighting technique. The effect of the signal-to-noise ratio on the MF focusing factor is also discussed.
Shi, Rui; Zhang, Shilei; Xu, Hang; Liu, Xufeng; Miao, Danmin
2015-12-01
This correlation study investigated the relationship between nurses' regulatory focus and burnout, as mediated by their perceptions of transformational leadership, using a cross-sectional research design with anonymous questionnaires. In July-August 2012, data were collected from 378 nurses from three hospitals in Shaanxi Province, China, using self-report questionnaires for measuring the nurses' regulatory focus, their level of burnout and their perception of whether the leadership of their supervisor was transformational. Structural equation modelling and bootstrapping procedures were used to identify the mediating effect of their perceptions of transformational leadership. The results supported our hypothesized model. The type of regulatory focus emerged as a significant predictor of burnout. Having a perception of transformational leadership partially mediated the relationship between regulatory focus and burnout. Having a promotion focus reduced burnout when the participants perceived transformational leadership, whereas having a prevention focus exhibited the opposite pattern. The mediating effect of the perception of transformational leadership suggests that a promotion focus may help diminish burnout, directly and indirectly. Nurse managers must be aware of the role of a regulatory focus and cultivate promotion focus in their followers. © 2014 Wiley Publishing Asia Pty Ltd.
Differences in children's thinking and learning during attentional focus instruction.
Perreault, Melanie E; French, Karen E
2016-02-01
Considerable evidence supports the motor learning advantage associated with an external focus of attention; however, very few studies have investigated attentional focus effects with children despite individual functional constraints that have the potential to impact use of instructional content. Thus, the purpose of this study was to determine the effect of attentional focus instruction on motor learning in children. Participants (n=42) aged 9-11years were randomly assigned to one of three gender-stratified groups: (1) control, (2) internal focus, or (3) external focus. Following initial instructions and task demonstration, participants performed 100 modified free throws over two days while receiving additional cues respective to their attentional focus condition and returned approximately 48h later to perform 20 additional free throws. Results revealed no significant learning differences between groups. However, responses to retrospective verbal reports suggest that the use of external focus content during practice may have contributed to some participants' superior performance in retention. Future research should continue to examine attentional focus effects across a variety of ages and incorporate retrospective verbal reports in order to examine children's thoughts during attentional focus instruction. Copyright © 2015 Elsevier B.V. All rights reserved.
Renner, Kerry A; Valentiner, David P; Holzman, Jacob B
2017-01-01
A clinical protocol based on contemporary cognitive behavioral treatment for social anxiety was developed and examined. Previously published instructions for conducting a focus-of-attention behavioral experiment targeting self-focused attention and safety behaviors during exposure were used to create a structured protocol. Individuals (n = 45) with high levels of social anxiety and public-speaking anxiety were randomly assigned to either a focus-of-attention behavioral experiment (FABE) or an Exposure-Only Control (EOC) condition. During four exposure trials, those in the FABE condition (n = 24) were alternately instructed to engage in self-focused attention vs. externally focused attention and to eliminate safety behaviors. Those in the EOC condition (n = 21) were not so instructed. At post-intervention, individuals in the FABE condition showed significantly less self-focused attention and anxiety, and better observed performance as rated by audience members. Focus-of-attention statistically mediated the effect of condition on anxiety. For those in the FABE condition, the degree of association between focus-of-attention and anxiety during the intervention predicted less self-focused attention post-intervention. The FABE appears to be a useful procedure for implementing part of the contemporary cognitive behavioral treatment model.
Low voltage operation of plasma focus.
Shukla, Rohit; Sharma, S K; Banerjee, P; Das, R; Deb, P; Prabahar, T; Das, B K; Adhikary, B; Shyam, A
2010-08-01
Plasma foci of compact sizes and operating with low energies (from tens of joules to few hundred joules) have found application in recent years and have attracted plasma-physics scientists and engineers for research in this direction. We are presenting a low energy and miniature plasma focus which operates from a capacitor bank of 8.4 muF capacity, charged at 4.2-4.3 kV and delivering approximately 52 kA peak current at approximately 60 nH calculated circuit inductance. The total circuit inductance includes the plasma focus inductance. The reported plasma focus operates at the lowest voltage among all reported plasma foci so far. Moreover the cost of capacitor bank used for plasma focus is nearly 20 U.S. dollars making it very cheap. At low voltage operation of plasma focus, the initial breakdown mechanism becomes important for operation of plasma focus. The quartz glass tube is used as insulator and breakdown initiation is done on its surface. The total energy of the plasma focus is approximately 75 J. The plasma focus system is made compact and the switching of capacitor bank energy is done by manual operating switch. The focus is operated with hydrogen and deuterium filled at 1-2 mbar.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Reece, Amy E.; Oakey, John, E-mail: joakey@uwyo.edu
2016-04-15
The controlled and directed focusing of particles within flowing fluids is a problem of fundamental and technological significance. Microfluidic inertial focusing provides passive and precise lateral and longitudinal alignment of small particles without the need for external actuation or sheath fluid. The benefits of inertial focusing have quickly enabled the development of miniaturized flow cytometers, size-selective sorting devices, and other high-throughput particle screening tools. Straight channel inertial focusing device design requires knowledge of fluid properties and particle-channel size ratio. Equilibrium behavior of inertially focused particles has been extensively characterized and the constitutive phenomena described by scaling relationships for straight channelsmore » of square and rectangular cross section. In concentrated particle suspensions, however, long-range hydrodynamic repulsions give rise to complex particle ordering that, while interesting and potentially useful, can also dramatically diminish the technique’s effectiveness for high-throughput particle handling applications. We have empirically investigated particle focusing behavior within channels of increasing aspect ratio and have identified three scaling regimes that produce varying degrees of geometrical ordering between focused particles. To explore the limits of inertial particle focusing and identify the origins of these long-range interparticle forces, we have explored equilibrium focusing behavior as a function of channel geometry and particle concentration. Experimental results for highly concentrated particle solutions identify equilibrium thresholds for focusing that scale weakly with concentration and strongly with channel geometry. Balancing geometry mediated inertial forces with estimates for interparticle repulsive forces now provide a complete picture of pattern formation among concentrated inertially focused particles and enhance our understanding of the fundamental limits of inertial focusing for technological applications.« less
Semantic focusing allows fully automated single-layer slide scanning of cervical cytology slides.
Lahrmann, Bernd; Valous, Nektarios A; Eisenmann, Urs; Wentzensen, Nicolas; Grabe, Niels
2013-01-01
Liquid-based cytology (LBC) in conjunction with Whole-Slide Imaging (WSI) enables the objective and sensitive and quantitative evaluation of biomarkers in cytology. However, the complex three-dimensional distribution of cells on LBC slides requires manual focusing, long scanning-times, and multi-layer scanning. Here, we present a solution that overcomes these limitations in two steps: first, we make sure that focus points are only set on cells. Secondly, we check the total slide focus quality. From a first analysis we detected that superficial dust can be separated from the cell layer (thin layer of cells on the glass slide) itself. Then we analyzed 2,295 individual focus points from 51 LBC slides stained for p16 and Ki67. Using the number of edges in a focus point image, specific color values and size-inclusion filters, focus points detecting cells could be distinguished from focus points on artifacts (accuracy 98.6%). Sharpness as total focus quality of a virtual LBC slide is computed from 5 sharpness features. We trained a multi-parameter SVM classifier on 1,600 images. On an independent validation set of 3,232 cell images we achieved an accuracy of 94.8% for classifying images as focused. Our results show that single-layer scanning of LBC slides is possible and how it can be achieved. We assembled focus point analysis and sharpness classification into a fully automatic, iterative workflow, free of user intervention, which performs repetitive slide scanning as necessary. On 400 LBC slides we achieved a scanning-time of 13.9±10.1 min with 29.1±15.5 focus points. In summary, the integration of semantic focus information into whole-slide imaging allows automatic high-quality imaging of LBC slides and subsequent biomarker analysis.
Light focusing using epsilon-near-zero metamaterials
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhu, Weiren, E-mail: weiren.zhu@monash.edu; Premaratne, Malin; Si, Li-Ming, E-mail: lms@bit.edu.cn
2013-11-15
We present a strategy of focusing light using epsilon-near-zero metamaterials with embedded dielectric cylinder. The focusing mechanism is analytically investigated, and its accuracy is substantiated by rigorous full-wave simulations. It is found that the focusing intensity is highly depend on the embedded medium and its size, and the magnetic field amplitude of the focused beam itself can reach as high as 98.2 times the incident field. Owing to its versatility, the proposed light focusing system is sure to find applications in fields such as bio-sensing and in nonlinear optics.
Handbook of clinical nursing practice
DOE Office of Scientific and Technical Information (OSTI.GOV)
Asheervath, J.; Blevins, D.R.
Written in outline format, this reference will help nurses further their understanding of advanced nursing procedures. Information is provided on the physiological, psychological, environmental, and safety considerations of nursing activities associated with diagnostic and therapeutic procedures. Special consideration is given to the areas of pediatric nursing, nursing assessment, and selected radiologic and nuclear medicine procedures for each system. Contents: Clinical Introduction. Clinical Nursing Practice: Focus on Basics. Focus on Cardiovascular Function. Focus on Respiratory Function. Focus on Gastrointestinal Function. Focus on Renal and Genito-Urological Function. Focus on Neuro-Skeletal and Muscular Function. Appendices.
Porter, Jared M.; Nolan, Russell P.; Ostrowski, Erik J.; Wulf, Gabriele
2010-01-01
The primary purpose of this study was to investigate if focusing attention externally produced faster movement times compared to instructions that focused attention internally or a control set of instructions that did not explicitly focus attention when performing an agility task. A second purpose of the study was to measure participants’ focus of attention during practice by use of a questionnaire. Participants (N = 20) completed 15 trials of an agility “L” run following instructions designed to induce an external (EXT), internal (INT) attentional focus or a control (CON) set of instructions inducing no specific focus of attention. Analysis revealed when participants followed the EXT instructions they had significantly faster movement times compared to when they followed the INT and CON set of instructions; consistent with previous research the INT and CON movement times were not significantly different from each other. Qualitative data showed when participants were in the external condition they focused externally 67% of the time. When they were in the internal condition they focused internally 76% of the time, and when they were in the control condition they did not use an internal or external focus of attention 77% of the time. Qualitative data also revealed participants in the EXT, INT, and CON conditions switched their focus of attention at a frequency of 27, 35, and 51% respectively. PMID:21833271
Ståhl, Tomas; Van Laar, Colette; Ellemers, Naomi
2012-06-01
Previous research has demonstrated that stereotype threat induces a prevention focus and impairs central executive functions. The present research examines how these 2 consequences of stereotype threat are related. The authors argue that the prevention focus is responsible for the effects of stereotype threat on executive functions and cognitive performance. However, because the prevention focus is adapted to deal with threatening situations, the authors propose that it also leads to some beneficial responses to stereotype threat. Specifically, because stereotype threat signals a high risk of failure, a prevention focus initiates immediate recruitment of cognitive control resources. The authors further argue that this response initially facilitates cognitive performance but that the additional cognitive demands associated with working under threat lead to cognitive depletion over time. Study 1 demonstrates that stereotype threat (vs. control) facilitates immediate cognitive control capacity during a stereotype-relevant task. Study 2 experimentally demonstrates the process by showing that stereotype threat (vs. control) facilitates cognitive control as a default, as well as when a prevention focus has been experimentally induced, but not when a promotion focus has been induced. Study 3 shows that stereotype threat facilitates initial math performance under a prevention focus, whereas no effect is found under a promotion focus. Consistent with previous research, however, stereotype threat impaired math performance over time under a prevention focus, but not under a promotion focus. 2012 APA, all rights reserved
Framing matters: contextual influences on interracial interaction outcomes.
Babbitt, Laura G; Sommers, Samuel R
2011-09-01
Previous studies indicate that interracial interactions frequently have negative outcomes but have typically focused on social contexts. The current studies examined the effect of manipulating interaction context. In Study 1, Black and White participants worked together with instructions that created either a social focus or a task focus. With a task focus, interracial pairs were more consistently synchronized, Black participants showed less executive function depletion, and White participants generally showed reduced implicit bias. Follow-up studies suggested that prejudice concerns help explain these findings: White participants reported fewer concerns about appearing prejudiced when they imagined an interracial interaction with a task focus rather than a social focus (Study 2a), and Black participants reported less vigilance against prejudice in an imagined interracial interaction with a task focus rather than a social focus (Study 2b). Taken together, these studies illustrate the importance of interaction context for the experiences of both Blacks and Whites.
Vogel, Tobias; Genschow, Oliver
2013-04-01
Research on regulatory focus theory (Higgins, 1997) suggests that performance increases if instructions fit with sportspersons' dispositions. Sportspersons who chronically focus on wins (i.e., promotion-oriented individuals) perform best if instructions frame the objective as a promotion goal (e.g., "Try to hit!"). By contrast, sportspersons who chronically focus on losses (i.e., prevention-oriented individuals) perform best if instructions frame the objective as a prevention goal (e.g., "Try not to miss!"). Recent theorizing also suggests that regulatory focus interacts with task difficulty. In an experiment, we assessed soccer performance as a function of chronic focus, instructional focus, and task difficulty. Results support that task difficulty moderates the effects of fit on performance; fitting instructions to match the sportsperson's chronic regulatory focus improved performance in the easy rather than the difficult task. Findings are discussed regarding the role of regulatory fit in altering subjective pressure during sports performance.
Adaptive DOF for plenoptic cameras
NASA Astrophysics Data System (ADS)
Oberdörster, Alexander; Lensch, Hendrik P. A.
2013-03-01
Plenoptic cameras promise to provide arbitrary re-focusing through a scene after the capture. In practice, however, the refocusing range is limited by the depth of field (DOF) of the plenoptic camera. For the focused plenoptic camera, this range is given by the range of object distances for which the microimages are in focus. We propose a technique of recording light fields with an adaptive depth of focus. Between multiple exposures { or multiple recordings of the light field { the distance between the microlens array (MLA) and the image sensor is adjusted. The depth and quality of focus is chosen by changing the number of exposures and the spacing of the MLA movements. In contrast to traditional cameras, extending the DOF does not necessarily lead to an all-in-focus image. Instead, the refocus range is extended. There is full creative control about the focus depth; images with shallow or selective focus can be generated.
Flying Focus: Spatiotemporal Control of the Laser Beam Intensity
NASA Astrophysics Data System (ADS)
Froula, D. H.; Turnbull, D.; Kessler, T. J.; Haberberger, D.; Bahk, S.-W.; Begishev, I. A.; Boni, R.; Bucht, S.; Davies, A.; Katz, J.; Sefkow, A. B.; Shaw, J. L.
2017-10-01
A ``flying focus'' is presented: this advanced focusing scheme provides unprecedented spatiotemporal control over the laser focal volume. A chromatic focusing system combined with chirped laser pulses enabled the speed of a small-diameter laser focus to propagate over nearly 100 × its Rayleigh length. Furthermore, the flying focus decouples the speed at which the peak intensity propagates from the group velocity of the laser pulse, allowing the laser focus to co- or counter-propagate along its axis at any velocity. Experiments have demonstrated a nearly constant intensity over 4.5 mm while the velocity of the focus ranged from subluminal (0.01 c) to superluminal (15 c) . These properties could provide the opportunity to overcome current fundamental limitations in laser-plasma amplifiers, laser-wakefield accelerators, photon accelerators, ion accelerators, and high-order frequency conversion. This material is based upon work supported by the Department of Energy National Nuclear Security Administration under Award Number DE-NA0001944.
Electron-Focus Adjustment for Photo-Optical Imagers
NASA Technical Reports Server (NTRS)
Fowler, Walter B.; Flemming, Keith; Ziegler, Michael M.
1987-01-01
Internal electron focus made independent of optical focus. Procedure enables fine tuning of internal electron-focusing system of photo-optical imager, without complication by imperfections of associated external optics. Applicable to imager in which electrons emitted from photocathode in optical focal plane, then electrostatically and/or magnetically focused to replica of image in second focal plane containing photodiodes, phototransistorss, charge-coupled devices, multiple-anode outputs, or other detectors.
ERIC Educational Resources Information Center
Neumann, Sandra; Salm, Sandra; Rietz, Christian; Stenneken, Prisca
2017-01-01
Purpose: Our purpose was to explore the validity and reliability of the German Focus on the Outcomes of Communication Under Six (FOCUS-G; Thomas-Stonell, Oddson, Robertson, & Rosenbaum, 2010, 2012), which is an authorized adaptation of the Focus on the Outcomes of Communication Under Six (Thomas-Stonell et al., 2010) tool, which measures…
Focusing of concentric piecewise vector Bessel-Gaussian beam
NASA Astrophysics Data System (ADS)
Li, Jinsong; Fang, Ying; Zhou, Shenghua; Ye, Youxiang
2010-12-01
The focusing properties of a concentric piecewise vector Bessel-Gaussian beam are investigated in this paper. The beam consists of three portions: the center circular portion and outer annular portion are radially polarized, while the inner annular portion is generalized polarized with tunable polarized angle. Numerical simulations show that the evolution of focal pattern is altered considerably with different Bessel parameters in the Bessel term of the vector Bessel-Gaussian beam. The polarized angle also affects the focal pattern remarkably. Some interesting focal patterns may appear, such as two-peak, dark hollow focus; ring focus; spherical shell focus; cylindrical shell focus; and multi-ring-peak focus, and transverse focal switch occurs with increasing polarized angle of the inner annular portion, which may be used in optical manipulation.
Electrostatic focusing of directly heated linear filament gun using EGUN
NASA Astrophysics Data System (ADS)
Iqbal, Munawar; Lodhi, M. A. K.; Majeed, Zahid; Batani, Dimitri
2011-06-01
This paper presents the optimization of a line source rectangular electron gun using electrostatic focusing. We optimized the gun by shaping the configuration of its electrodes in order to achieve the desired focusing characteristics, namely maximum focusing distance and minimum beam spread. The optimization has been carried out using the software EGUN. We have also simplified the gun design using only one focusing electrode at the same potential as that of the cathode and by avoiding magnetic focusing field, separate focusing electrodes and additional power supply, thus minimizing the cost without any loss in its accuracy and efficient performance. This gun with the optimum configuration was used in actual experiment and the results of the simulation were compared with the experimental measurements.
Bus commuters' coping strategies and anxiety from terrorism: an example of the Israeli experience.
Gidron, Y; Gal, R; Zahavi, S
1999-01-01
This study examined the use of three coping strategies: (1) emotion-focused coping (calming-distraction); (2) problem-focused coping (checking-behavior); and (3) denial (reduced perceived vulnerability), and their relationship to anxiety from terrorism among 50 Israeli bus commuters. Their mean age was 31 years (60% females). Commuting frequency was negatively correlated, and problem-focused coping was positively correlated with anxiety from terrorism. Ratios of problem-focused coping/denial and of problem-focused/emotion-focused coping were each positively correlated with anxiety from terrorism. Coping ratios accounted for 15% of the variance in anxiety from terrorism, after considering commuting frequency. Combining minimal problem-focused preventative acts with distraction and reduced perceived vulnerability may be beneficial.
Jang, Jinbeum; Yoo, Yoonjong; Kim, Jongheon; Paik, Joonki
2015-03-10
This paper presents a novel auto-focusing system based on a CMOS sensor containing pixels with different phases. Robust extraction of features in a severely defocused image is the fundamental problem of a phase-difference auto-focusing system. In order to solve this problem, a multi-resolution feature extraction algorithm is proposed. Given the extracted features, the proposed auto-focusing system can provide the ideal focusing position using phase correlation matching. The proposed auto-focusing (AF) algorithm consists of four steps: (i) acquisition of left and right images using AF points in the region-of-interest; (ii) feature extraction in the left image under low illumination and out-of-focus blur; (iii) the generation of two feature images using the phase difference between the left and right images; and (iv) estimation of the phase shifting vector using phase correlation matching. Since the proposed system accurately estimates the phase difference in the out-of-focus blurred image under low illumination, it can provide faster, more robust auto focusing than existing systems.
Jang, Jinbeum; Yoo, Yoonjong; Kim, Jongheon; Paik, Joonki
2015-01-01
This paper presents a novel auto-focusing system based on a CMOS sensor containing pixels with different phases. Robust extraction of features in a severely defocused image is the fundamental problem of a phase-difference auto-focusing system. In order to solve this problem, a multi-resolution feature extraction algorithm is proposed. Given the extracted features, the proposed auto-focusing system can provide the ideal focusing position using phase correlation matching. The proposed auto-focusing (AF) algorithm consists of four steps: (i) acquisition of left and right images using AF points in the region-of-interest; (ii) feature extraction in the left image under low illumination and out-of-focus blur; (iii) the generation of two feature images using the phase difference between the left and right images; and (iv) estimation of the phase shifting vector using phase correlation matching. Since the proposed system accurately estimates the phase difference in the out-of-focus blurred image under low illumination, it can provide faster, more robust auto focusing than existing systems. PMID:25763645
Computerized method and system for designing an aerodynamic focusing lens stack
Gard, Eric [San Francisco, CA; Riot, Vincent [Oakland, CA; Coffee, Keith [Diablo Grande, CA; Woods, Bruce [Livermore, CA; Tobias, Herbert [Kensington, CA; Birch, Jim [Albany, CA; Weisgraber, Todd [Brentwood, CA
2011-11-22
A computerized method and system for designing an aerodynamic focusing lens stack, using input from a designer related to, for example, particle size range to be considered, characteristics of the gas to be flowed through the system, the upstream temperature and pressure at the top of a first focusing lens, the flow rate through the aerodynamic focusing lens stack equivalent at atmosphere pressure; and a Stokes number range. Based on the design parameters, the method and system determines the total number of focusing lenses and their respective orifice diameters required to focus the particle size range to be considered, by first calculating for the orifice diameter of the first focusing lens in the Stokes formula, and then using that value to determine, in iterative fashion, intermediate flow values which are themselves used to determine the orifice diameters of each succeeding focusing lens in the stack design, with the results being output to a designer. In addition, the Reynolds numbers associated with each focusing lens as well as exit nozzle size may also be determined to enhance the stack design.
Frequent external-focus feedback enhances motor learning.
Wulf, Gabriele; Chiviacowsky, Suzete; Schiller, Eduardo; Avila, Luciana Toaldo Gentilini
2010-01-01
The present study examined the hypothesis that feedback inducing an external focus of attention enhances motor learning if it is provided frequently (i.e., 100%) rather than less frequently. Children (10- to 12-year-olds) practiced a soccer throw-in task and were provided feedback about movement form. The feedback statements, provided either after every (100%) or every third (33%) practice trial, were similar in content but induced either an internal focus (body-movement related) or external focus (movement-effect related). The results demonstrated that learning of the movement form was enhanced by external-focus feedback after every trial (100%) relative to external-focus feedback after every third trial (33%) or internal-focus feedback (100%, 33%), as demonstrated by immediate and delayed transfer tests without feedback. There was no difference between the two internal-focus feedback groups. These findings indicate that the attentional focus induced by feedback is an important factor in determining the effectiveness of different feedback frequencies. We argue that the informational properties of feedback cannot sufficiently account for these and related findings, and suggest that the attentional role of feedback be given greater consideration in future studies.
Consequences of Incorrect Focus Cues in Stereo Displays
Banks, Martin S.; Akeley, Kurt; Hoffman, David M.; Girshick, Ahna R.
2010-01-01
Conventional stereo displays produce images in which focus cues – blur and accommodation – are inconsistent with the simulated depth. We have developed new display techniques that allow the presentation of nearly correct focus. Using these techniques, we find that stereo vision is faster and more accurate when focus cues are mostly consistent with simulated depth; furthermore, viewers experience less fatigue when focus cues are correct or nearly correct. PMID:20523910
X-ray emission from high temperature plasmas
NASA Technical Reports Server (NTRS)
Harries, W. L.
1977-01-01
The physical processes occurring in plasma focus devices were investigated with particular emphasis on X-ray emission. Topics discussed include: trajectories of high energy electrons; detection of ion trajectories; spatial distribution of neutron emission; space and time resolved emission of hard X-rays from a plasma focus; the staged plasma focus as a variation of the hypocloidal pinch; formation of current sheets in a staged plasma focus; and X-ray and neutron emission from a staged plasma focus. The possibility of operating dense plasma-focus type devices in multiple arrays beyond the scaling law for a single gun is discussed.
Kruijsen-Terpstra, Anne J A; Ellens, Mariëlle; Ketelaar, Marjolijn; Verschuren, Olaf; Di Rezze, Briano; Gorter, Jan Willem; Visser-Meily, Anne M A; Jongmans, Marian J
2016-11-01
To (1) describe the child- and context-focused behaviors of physical and occupational therapists, and (2) compare the behaviors of therapists in a standard therapy session with those of therapists trained to deliver child- and context-focused services. Videos of 49 therapy sessions provided by 36 therapists were analyzed using the intervention domains of the Paediatric Rehabilitation Observational measure of Fidelity (PROF) to examine the therapeutic behaviors of physical and occupational therapists with young children with cerebral palsy (CP) (24 to 48 months) in a Dutch rehabilitation setting. The PROF ratings of 18 standard therapy sessions were compared with the ratings of 16 child- and 15 context-focused therapy sessions. Therapists who provided standard therapy demonstrated a mix of child- and context-focused behaviors. PROF ratings indicated fewer child- and context-focused behaviors during standard therapy sessions compared with sessions where therapists were instructed to use either child- or context-focused behaviors. A sample of Dutch physical and occupational therapists of young children with CP demonstrated a mix of child- and context-focused therapy behaviors during standard therapy. Further research is recommended on clinical reasoning and the effect of setting to better understand therapists' use of child- and context-focused behaviors during therapy sessions.
CRISPR-FOCUS: A web server for designing focused CRISPR screening experiments.
Cao, Qingyi; Ma, Jian; Chen, Chen-Hao; Xu, Han; Chen, Zhi; Li, Wei; Liu, X Shirley
2017-01-01
The recently developed CRISPR screen technology, based on the CRISPR/Cas9 genome editing system, enables genome-wide interrogation of gene functions in an efficient and cost-effective manner. Although many computational algorithms and web servers have been developed to design single-guide RNAs (sgRNAs) with high specificity and efficiency, algorithms specifically designed for conducting CRISPR screens are still lacking. Here we present CRISPR-FOCUS, a web-based platform to search and prioritize sgRNAs for CRISPR screen experiments. With official gene symbols or RefSeq IDs as the only mandatory input, CRISPR-FOCUS filters and prioritizes sgRNAs based on multiple criteria, including efficiency, specificity, sequence conservation, isoform structure, as well as genomic variations including Single Nucleotide Polymorphisms and cancer somatic mutations. CRISPR-FOCUS also provides pre-defined positive and negative control sgRNAs, as well as other necessary sequences in the construct (e.g., U6 promoters to drive sgRNA transcription and RNA scaffolds of the CRISPR/Cas9). These features allow users to synthesize oligonucleotides directly based on the output of CRISPR-FOCUS. Overall, CRISPR-FOCUS provides a rational and high-throughput approach for sgRNA library design that enables users to efficiently conduct a focused screen experiment targeting up to thousands of genes. (CRISPR-FOCUS is freely available at http://cistrome.org/crispr-focus/).
Monolithic hybrid optics for focusing ultrashort laser pulses
NASA Astrophysics Data System (ADS)
Fuchs, U.
2014-03-01
Almost any application of ultrashort laser pulses involves focusing them in order to reach high intensities and/or small spot sizes as needed for micro-machining or Femto-LASIK. Hence, it is indispensable to be able to understand pulse front distortion caused by real world optics. Focusing causes pulse front distortion due to aberrations, dispersion and diffraction. Thus, the spatio-temporal profile of ultrashort laser is altered, which increases automatically the pulse duration and the focusing spot. Consequently, the main advantage of having ultrashort laser pulses - pulse durations way below 100 fs - can be lost in that one last step of the experimental set-up by focusing them unfavorable. Since compensating for dispersion, aberration and diffraction effects is quite complicated and not always possible, we pursue a different approach. We present a specially designed monolithic hybrid optics comprising refraction and diffraction effects for tight spatial and temporal focusing of ultrashort laser pulses. Both aims can be put into practice by having a high numerical aperture (NA = 0.35) and low internal dispersion at the same time. The focusing properties are very promising, due to a design, which provides diffraction limited focusing for 100 nm bandwidth at 780 nm center wavelength. Thus, pulses with durations as short as 10 fs can be focused without pulse front distortion. The outstanding performance of this optics is shown in theory and experimentally. Above that, such focusing optics are easily adapted to their special purpose - changing the center wavelength, achromatic bandwidth or even correcting for focusing into material is possible.
Servo-controlled intravital microscope system
NASA Technical Reports Server (NTRS)
Mansour, M. N.; Wayland, H. J.; Chapman, C. P. (Inventor)
1975-01-01
A microscope system is described for viewing an area of a living body tissue that is rapidly moving, by maintaining the same area in the field-of-view and in focus. A focus sensing portion of the system includes two video cameras at which the viewed image is projected, one camera being slightly in front of the image plane and the other slightly behind it. A focus sensing circuit for each camera differentiates certain high frequency components of the video signal and then detects them and passes them through a low pass filter, to provide dc focus signal whose magnitudes represent the degree of focus. An error signal equal to the difference between the focus signals, drives a servo that moves the microscope objective so that an in-focus view is delivered to an image viewing/recording camera.
Lee, A Y; Aaker, J L; Gardner, W L
2000-06-01
Regulatory focus theory distinguishes between self-regulatory processes that focus on promotion and prevention strategies for goal pursuit. Five studies provide support for the hypothesis that these strategies differ for individuals with distinct self-construals. Specifically, individuals with a dominant independent self-construal were predicted to place more emphasis on promotion-focused information, and those with a dominant interdependent self-construal on prevention-focused information. Support for this hypothesis was obtained for participants who scored high versus low on the Self-Construal Scale, participants who were presented with an independent versus interdependent situation, and participants from a Western versus Eastern culture. The influence of interdependence on regulatory focus was observed in both importance ratings of information and affective responses consistent with promotion or prevention focus.
Phase-shift focus monitoring techniques
NASA Astrophysics Data System (ADS)
McQuillan, Matthew; Roberts, Bill
2006-03-01
Depth of focus (DOF) has become a victim of its mathematical relationship with Numerical Aperture (NA). While NA is being increased towards one to maximize scanner resolution capabilities, DOF is being minimized because of its inverse relationship with NA. Moore's law continues to drive the semiconductor industry towards smaller and smaller devices the need for high NA to resolve these shrinking devices will continue to consume the usable depth of focus (UDOF). Due to the shrinking UDOF a demand has been created for a feature or technology that will give engineers the capability to monitor scanner focus. Developing and implementation of various focus monitoring techniques have been used to prevent undetected tool focus excursions. Two overlay techniques to monitor ArF Scanner focus have been evaluated; our evaluation results will be presented here.
Age Differences in Consumer Decision Making under Option Framing: From the Motivation Perspective
Peng, Huamao; Xia, Shiyong; Ruan, Fanglin; Pu, Bingyan
2016-01-01
Option framing effect is the phenomena that participants often accept more options when they are asked to delete undesired options from a full model (subtractive framing) than they do when they are instructed to add desired options to a base model (additive framing). Whether the same effect exists in different age groups is less well known. To explore the roles of age and purchase motivations on the option framing effect for automobiles purchases, this study adopted a 3 (age group: younger, middle-aged, vs. older) × 2 (option framing: additive vs. subtractive) × 2 (focus condition: information vs. emotion) mixed design. To manipulate purchase motivations, participants in the three age groups were instructed to focus on the ratio of utility and price of options (information-focus) or the extent of pleasure induced by the options (emotion-focus) when they made purchase decisions in two framing conditions. The results revealed similar option framing effect across all age groups in the information-focus condition regarding the total price paid for accepted options. In contrast, the framing effect was not found in the emotion-focus condition. In addition, older adults accepted more options and an overall higher price than younger and middle-aged adults in both focus conditions. This difference was more obvious in the emotion-focus condition than in the information-focus condition. Moreover, both the number of accepted options and the total accepted price of the younger group in the information-focus condition were higher than those in the emotion-focus condition, whereas the older and middle-aged groups accepted same number of options and price between two focus conditions. These results imply that purchase motivation is a moderator of the option framing effect and age characteristics linked with motivations must be considered in sales. PMID:27872603
Age Differences in Consumer Decision Making under Option Framing: From the Motivation Perspective.
Peng, Huamao; Xia, Shiyong; Ruan, Fanglin; Pu, Bingyan
2016-01-01
Option framing effect is the phenomena that participants often accept more options when they are asked to delete undesired options from a full model (subtractive framing) than they do when they are instructed to add desired options to a base model (additive framing). Whether the same effect exists in different age groups is less well known. To explore the roles of age and purchase motivations on the option framing effect for automobiles purchases, this study adopted a 3 (age group: younger, middle-aged, vs. older) × 2 (option framing: additive vs. subtractive) × 2 (focus condition: information vs. emotion) mixed design. To manipulate purchase motivations, participants in the three age groups were instructed to focus on the ratio of utility and price of options (information-focus) or the extent of pleasure induced by the options (emotion-focus) when they made purchase decisions in two framing conditions. The results revealed similar option framing effect across all age groups in the information-focus condition regarding the total price paid for accepted options. In contrast, the framing effect was not found in the emotion-focus condition. In addition, older adults accepted more options and an overall higher price than younger and middle-aged adults in both focus conditions. This difference was more obvious in the emotion-focus condition than in the information-focus condition. Moreover, both the number of accepted options and the total accepted price of the younger group in the information-focus condition were higher than those in the emotion-focus condition, whereas the older and middle-aged groups accepted same number of options and price between two focus conditions. These results imply that purchase motivation is a moderator of the option framing effect and age characteristics linked with motivations must be considered in sales.
Degree of host susceptibility in the initial disease outbreak influences subsequent epidemic spread
Severns, Paul M.; Estep, Laura K.; Sackett, Kathryn E.; Mundt, Christopher C.
2014-01-01
Summary Disease epidemics typically begin as an outbreak of a relatively small, spatially explicit population of infected individuals (focus), in which disease prevalence increases and rapidly spreads into the uninfected, at-risk population. Studies of epidemic spread typically address factors influencing disease spread through the at-risk population, but the initial outbreak may strongly influence spread of the subsequent epidemic.We initiated wheat stripe rust Puccinia striiformis f. sp. tritici epidemics to assess the influence of the focus on final disease prevalence when the degree of disease susceptibility differed between the at-risk and focus populations.When the focus/at-risk plantings consisted of partially genetic resistant and susceptible cultivars, final disease prevalence was statistically indistinguishable from epidemics produced by the focus cultivar in monoculture. In these experimental epidemics, disease prevalence was not influenced by the transition into an at-risk population that differed in disease susceptibility. Instead, the focus appeared to exert a dominant influence on the subsequent epidemic.Final disease prevalence was not consistently attributable to either the focus or the at-risk population when focus/at-risk populations were planted in a factorial set-up with a mixture (~28% susceptible and 72% resistant) and susceptible individuals. In these experimental epidemics, spatial heterogeneity in disease susceptibility within the at-risk population appeared to counter the dominant influence of the focus.Cessation of spore production from the focus (through fungicide/glyphosate application) after 1.3 generations of stripe rust spread did not reduce final disease prevalence, indicating that the focus influence on disease spread is established early in the epidemic.Synthesis and applications. Our experiments indicated that outbreak conditions can be highly influential on epidemic spread, even when disease resistance in the at-risk population is greater than that of the focus. Disease control treatments administered shortly after the initial outbreak within the focus may either prevent an epidemic from occurring or reduce its severity. PMID:25512677
Techniques For Focusing In Zone Electrophoresis
NASA Technical Reports Server (NTRS)
Sharnez, Rizwan; Twitty, Garland E.; Sammons, David W.
1994-01-01
In two techniques for focusing in zone electrophoresis, force of applied electrical field in each charged particle balanced by restoring force of electro-osmosis. Two techniques: velocity-gradient focusing (VGF), suitable for rectangular electrophoresis chambers; and field-gradient focusing (FGF), suitable for step-shaped electrophoresis chambers.
Effects of Person- and Process-Focused Feedback on Prosocial Behavior in Middle Childhood
Dunsmore, Julie C.
2014-01-01
Effects of person- and process-focused feedback, parental lay theories, and prosocial self-concept on children’s prosocial behavior were investigated with 143 9- and 10-year-old children who participated in a single session. Parents reported entity (person-focused) and incremental (process-focused) beliefs related to prosocial behavior. Children completed measures of prosocial self-concept, then participated in a virtual online chat with child actors who asked for help with service projects. After completing the chat, children could assist with the service projects. In the first cohort, children were randomly assigned to receive person-focused, process-focused, or control feedback about sympathy. In the second cohort, with newly-recruited families, children received no feedback. When given process-focused feedback, children spent less time spent helping and worked on fewer service projects. When given no feedback, children spent less time helping when parents held incremental (process-focused) beliefs. Children with higher prosocial self-concept who received no feedback worked on more service projects. PMID:25684859
Retinal optical coherence tomography at 1 μm with dynamic focus control and axial motion tracking
NASA Astrophysics Data System (ADS)
Cua, Michelle; Lee, Sujin; Miao, Dongkai; Ju, Myeong Jin; Mackenzie, Paul J.; Jian, Yifan; Sarunic, Marinko V.
2016-02-01
High-resolution optical coherence tomography (OCT) retinal imaging is important to noninvasively visualize the various retinal structures to aid in better understanding of the pathogenesis of vision-robbing diseases. However, conventional OCT systems have a trade-off between lateral resolution and depth-of-focus. In this report, we present the development of a focus-stacking OCT system with automatic focus optimization for high-resolution, extended-focal-range clinical retinal imaging by incorporating a variable-focus liquid lens into the sample arm optics. Retinal layer tracking and selection was performed using a graphics processing unit accelerated processing platform for focus optimization, providing real-time layer-specific en face visualization. After optimization, multiple volumes focused at different depths were acquired, registered, and stitched together to yield a single, high-resolution focus-stacked dataset. Using this system, we show high-resolution images of the retina and optic nerve head, from which we extracted clinically relevant parameters such as the nerve fiber layer thickness and lamina cribrosa microarchitecture.
Rabinovich, Anna; Morton, Thomas A
2012-03-01
The authors investigated the impact of temporal focus on group members' responses to contextual ingroup devaluation. Four experimental studies demonstrated that following an induction of negative ingroup evaluation, participants primed with a past temporal focus reported behavioral intentions more consistent with this negative appraisal than participants primed with a future temporal focus. This effect was apparent only when a negative (but not a positive) evaluation was induced, and only among highly identified group members. Importantly, the interplay between temporal focus and group identification on relevant intentions was mediated by individual self-esteem, suggesting that focus on the future may be conducive to separating negative ingroup appraisals from individual self-evaluations. Taken together, the findings suggest that high identifiers' responses to ingroup evaluations may be predicated on their temporal focus: A focus on the past may lock such individuals within their group's history, whereas a vision of the future may open up opportunities for change.
Adaptation of Reactive Saccades is Influenced by Unconscious Priming of the Attention Focus.
Bock, Otmar; Grigorova, Valentina; Ilieva-Staneva, Milena
2017-01-01
The authors investigated whether the size of the attention focus can influence saccadic adaptation, and whether this influence changes in older age. Using the scrambled sentence task, young and older participants were either primed for a wide attention focus, or primed of a narrow attention focus, or were not primed for any specific attention focus. Subsequently, all participants underwent a double-step saccadic adaptation paradigm aimed at changing the direction of reflexive saccades. The authors found that compared to the nonprimed control group, priming for a wide attention focus enhanced saccadic adaptation in both age groups by a similar amount; the benefit persisted throughout the adaptation phase, but was absent during the deadaptation phase. In contrast, the authors found no effects of priming with a narrow attention focus on saccadic adaptation. From this the authors conclude that a wide attention focus is beneficial for workaround strategies but not for adaptive recalibration, and that those benefits are similar in young and older persons.
Deep-Focusing Time-Distance Helioseismology
NASA Technical Reports Server (NTRS)
Duvall, T. L., Jr.; Jensen, J. M.; Kosovichev, A. G.; Birch, A. C.; Fisher, Richard R. (Technical Monitor)
2001-01-01
Much progress has been made by measuring the travel times of solar acoustic waves from a central surface location to points at equal arc distance away. Depth information is obtained from the range of arc distances examined, with the larger distances revealing the deeper layers. This method we will call surface-focusing, as the common point, or focus, is at the surface. To obtain a clearer picture of the subsurface region, it would, no doubt, be better to focus on points below the surface. Our first attempt to do this used the ray theory to pick surface location pairs that would focus on a particular subsurface point. This is not the ideal procedure, as Born approximation kernels suggest that this focus should have zero sensitivity to sound speed inhomogeneities. However, the sensitivity is concentrated below the surface in a much better way than the old surface-focusing method, and so we expect the deep-focusing method to be more sensitive. A large sunspot group was studied by both methods. Inversions based on both methods will be compared.
Retinal optical coherence tomography at 1 μm with dynamic focus control and axial motion tracking.
Cua, Michelle; Lee, Sujin; Miao, Dongkai; Ju, Myeong Jin; Mackenzie, Paul J; Jian, Yifan; Sarunic, Marinko V
2016-02-01
High-resolution optical coherence tomography (OCT) retinal imaging is important to noninvasively visualize the various retinal structures to aid in better understanding of the pathogenesis of vision-robbing diseases. However, conventional OCT systems have a trade-off between lateral resolution and depth-of-focus. In this report, we present the development of a focus-stacking OCT system with automatic focus optimization for high-resolution, extended-focal-range clinical retinal imaging by incorporating a variable-focus liquid lens into the sample arm optics. Retinal layer tracking and selection was performed using a graphics processing unit accelerated processing platform for focus optimization, providing real-time layer-specific en face visualization. After optimization, multiple volumes focused at different depths were acquired, registered, and stitched together to yield a single, high-resolution focus-stacked dataset. Using this system, we show high-resolution images of the retina and optic nerve head, from which we extracted clinically relevant parameters such as the nerve fiber layer thickness and lamina cribrosa microarchitecture.
Regulatory focus affects predictions of the future.
Guo, Tieyuan; Spina, Roy
2015-02-01
This research investigated how regulatory focus might influence trend-reversal predictions. We hypothesized that compared with promotion focus, prevention focus hinders sense of control, which in turn predicts more trend-reversal developments. Studies 1 and 3 revealed that participants expected trend-reversal developments to be more likely to occur when they focused on prevention than when they focused on promotion. Study 2 extended the findings by including a control condition, and revealed that participants expected trend-reversal developments to be more likely to occur in the prevention condition than in the promotion and control conditions. Studies 4 and 5 revealed that participants' chronic prevention focus predicted a low sense of control (Study 4), and that promotion focus predicted a high sense of control (Studies 4 and 5). Furthermore, participants with a high sense of control expected trend-reversal developments to be less likely to occur. Thus, the results provided converging evidence for the hypothesis. © 2014 by the Society for Personality and Social Psychology, Inc.
Optical phase conjugation (OPC)-assisted isotropic focusing.
Jang, Mooseok; Sentenac, Anne; Yang, Changhuei
2013-04-08
Isotropic optical focusing - the focusing of light with axial confinement that matches its lateral confinement, is important for a broad range of applications. Conventionally, such focusing is achieved by overlapping the focused beams from a pair of opposite-facing microscope objective lenses. However the exacting requirements for the alignment of the objective lenses and the method's relative intolerance to sample turbidity have significantly limited its utility. In this paper, we present an optical phase conjugation (OPC)-assisted isotropic focusing method that can address both challenges. We exploit the time-reversal nature of OPC playback to naturally guarantee the overlap of the two focused beams even when the objective lenses are significantly misaligned (up to 140 microns transversely and 80 microns axially demonstrated). The scattering correction capability of OPC also enabled us to accomplish isotropic focusing through thick scattering samples (demonstrated with samples of ~7 scattering mean free paths). This method can potentially improve 4Pi microscopy and 3D microstructure patterning.
Saw-tooth refractive lens for high energy x-ray focusing
NASA Astrophysics Data System (ADS)
Antimonov, Mikhail A.; Khounsary, Ali M.
2014-09-01
Saw-tooth refractive lens (SRL) provides a comparatively attractive option for X-ray focusing. An SRL assembly consists of two parts, each with an array of triangular structures (prisms), set tilted symmetrically with respect to the incoming beam. Its main advantage is a simple, continuous tunability in energy and focal length. SRLs can be used for both long and short focal length focusing. Long focal distance focusing of an SRL can accurately be predicted using simple analytical relations. However, the focus size at short focal distances focusing may deviate appreciably from the expected demagnified source size when: (1) the length of the SRL is comparable with the focusing distance, (2) the incident beam is not monochromatic, and (3) and the distance between adjacent prism tips, the tip step, is large . The first factor was considered in a previous work while the other two are addressed is this paper. This preliminary work is aimed at a better understanding of the SRL lenses for focusing an undulator beamline at the Advanced Photon Source (APS).
Influence of encoding focus and stereotypes on source monitoring event-related-potentials.
Leynes, P Andrew; Nagovsky, Irina
2016-01-01
Source memory, memory for the origin of a memory, can be influenced by stereotypes and the information of focus during encoding processes. Participants studied words from two different speakers (male or female) using self-focus or other-focus encoding. Source judgments for the speaker׳s voice and Event-Related Potentials (ERPs) were recorded during test. Self-focus encoding increased dependence on stereotype information and the Late Posterior Negativity (LPN). The results link the LPN with an increase in systematic decision processes such as consulting prior knowledge to support an episodic memory judgment. In addition, other-focus encoding increased conditional source judgments and resulted in weaker old/new recognition relative to the self-focus encoding. The putative correlate of recollection (LPC) was absent during this condition and this was taken as evidence that recollection of partial information supported source judgments. Collectively, the results suggest that other-focus encoding changes source monitoring processing by altering the weight of specific memory features. Copyright © 2015 Elsevier B.V. All rights reserved.
In-Situ Focusing Inside a Thermal Vacuum Chamber
NASA Technical Reports Server (NTRS)
Liebe, Carl Christian; Hannah, Brett; Bartman, Randall; Radulescu, Costin; Rud, Mayer; Sarkissian, Edwin; Ho, Timothy; {p; Esposito, Joseph; Sutin, Brian;
2010-01-01
Traditionally, infrared (IR) space instruments have been focused by iterating with a number of different thickness shim rings in a thermal vacuum chamber until the focus meets requirements. This has required a number of thermal cycles that are very expensive as they tie up many integration and test (I&T)/ environmental technicians/engi neers work ing three shifts for weeks. Rather than creating a test shim for each iteration, this innovation replaces the test shim and can focus the instrument while in the thermal vacuum chamber. The focus tool consists of three small, piezo-actuated motors that drive two sets of mechanical interface flanges between the instrument optics and the focal- plane assembly, and three optical-displacement metrology sensors that can be read from outside the thermal vacuum chamber. The motors are used to drive the focal planes to different focal distances and acquire images, from which it is possible to determine the best focus. At the best focus position, the three optical displacement metrology sensors are used to determine the shim thickness needed. After the instrument leaves the thermal vacuum chamber, the focus tool is replaced with the precision-ground shim ring. The focus tool consists of two sets of collars, one that mounts to the backside of the interface flange of the instrument optics, and one that mounts to the backside of the interface flange of the focal plane modules. The collars on the instrument optics side have the three small piezo-actuated motors and the three optical displacement metrology systems. Before the instrument is focused, there is no shim ring in place and, therefore, no fasteners holding the focal plane modules to the cameras. Two focus tooling collars are held together by three strong springs. The Orbiting Carbon Observatory (OCO) mission spectrometer was focused this way (see figure). The motor described here had to be moved five times to reach an acceptable focus, all during the same thermal cycle, which was verified using pupil slicing techniques. A focus accuracy of .20.100 microns was achieved.
Scanner focus metrology and control system for advanced 10nm logic node
NASA Astrophysics Data System (ADS)
Oh, Junghun; Maeng, Kwang-Seok; Shin, Jae-Hyung; Choi, Won-Woong; Won, Sung-Keun; Grouwstra, Cedric; El Kodadi, Mohamed; Heil, Stephan; van der Meijden, Vidar; Hong, Jong Kyun; Kim, Sang-Jin; Kwon, Oh-Sung
2018-03-01
Immersion lithography is being extended beyond the 10-nm node and the lithography performance requirement needs to be tightened further to ensure good yield. Amongst others, good on-product focus control with accurate and dense metrology measurements is essential to enable this. In this paper, we will present new solutions that enable onproduct focus monitoring and control (mean and uniformity) suitable for high volume manufacturing environment. We will introduce the concept of pure focus and its role in focus control through the imaging optimizer scanner correction interface. The results will show that the focus uniformity can be improved by up to 25%.
Quiet is the new loud: pausing and focus in child and adult Dutch.
Romøren, Anna Sara H; Chen, Aoju
2015-03-01
In a number of languages, prosody is used to highlight new information (or focus). In Dutch, focus is marked by accentuation, whereby focal constituents are accented and post-focal constituents are de-accented. Even if pausing is not traditionally seen as a cue to focus in Dutch, several previous studies have pointed to a possible relationship between pausing and information structure. Considering that Dutch-speaking 4 to 5 year olds are not yet completely proficient in using accentuation for focus and that children generally pause more than adults, we asked whether pausing might be an available parameter for children to manipulate for focus. Sentences with varying focus structure were elicited from 10 Dutch-speaking 4 to 5 year olds and 9 Dutch-speaking adults by means of a picture-matching game. Comparing pause durations before focal and non-focal targets showed pre-target pauses to be significantly longer when the targets were focal than when they were not. Notably, the use of pausing was more robust in the children than in the adults, suggesting that children exploit pausing to mark focus more generally than adults do, at a stage where their mastery of the canonical cues to focus is still developing.
Optical phase conjugation assisted scattering lens: variable focusing and 3D patterning
Ryu, Jihee; Jang, Mooseok; Eom, Tae Joong; Yang, Changhuei; Chung, Euiheon
2016-01-01
Variable light focusing is the ability to flexibly select the focal distance of a lens. This feature presents technical challenges, but is significant for optical interrogation of three-dimensional objects. Numerous lens designs have been proposed to provide flexible light focusing, including zoom, fluid, and liquid-crystal lenses. Although these lenses are useful for macroscale applications, they have limited utility in micron-scale applications due to restricted modulation range and exacting requirements for fabrication and control. Here, we present a holographic focusing method that enables variable light focusing without any physical modification to the lens element. In this method, a scattering layer couples low-angle (transverse wave vector) components into a full angular spectrum, and a digital optical phase conjugation (DOPC) system characterizes and plays back the wavefront that focuses through the scattering layer. We demonstrate micron-scale light focusing and patterning over a wide range of focal distances of 22–51 mm. The interferometric nature of the focusing scheme also enables an aberration-free scattering lens. The proposed method provides a unique variable focusing capability for imaging thick specimens or selective photoactivation of neuronal networks. PMID:27049442
Space imaging infrared optical guidance for autonomous ground vehicle
NASA Astrophysics Data System (ADS)
Akiyama, Akira; Kobayashi, Nobuaki; Mutoh, Eiichiro; Kumagai, Hideo; Yamada, Hirofumi; Ishii, Hiromitsu
2008-08-01
We have developed the Space Imaging Infrared Optical Guidance for Autonomous Ground Vehicle based on the uncooled infrared camera and focusing technique to detect the objects to be evaded and to set the drive path. For this purpose we made servomotor drive system to control the focus function of the infrared camera lens. To determine the best focus position we use the auto focus image processing of Daubechies wavelet transform technique with 4 terms. From the determined best focus position we transformed it to the distance of the object. We made the aluminum frame ground vehicle to mount the auto focus infrared unit. Its size is 900mm long and 800mm wide. This vehicle mounted Ackerman front steering system and the rear motor drive system. To confirm the guidance ability of the Space Imaging Infrared Optical Guidance for Autonomous Ground Vehicle we had the experiments for the detection ability of the infrared auto focus unit to the actual car on the road and the roadside wall. As a result the auto focus image processing based on the Daubechies wavelet transform technique detects the best focus image clearly and give the depth of the object from the infrared camera unit.
Effect of attentional focus strategies on peak force and performance in the standing long jump.
Wu, Will F W; Porter, Jared M; Brown, Lee E
2012-05-01
Significant benefits in standing long jump performance have been demonstrated when subjects were provided verbal instructions that promoted an external focus of attention compared with an internal focus of attention, suggesting differences in ground reaction forces. The purpose of the present study was to evaluate peak force and jump performance between internal and external focus of attention strategies. Untrained subjects were assigned to both experimental conditions in which verbal instructions were provided to promote either an external or internal focus of attention. All subjects completed a total number of 5 standing long jumps. The results of the study demonstrated that the external focus of attention condition elicited significantly greater jump distance (153.6 ± 38.6 cm) than the internal focus of attention condition (139.5 ± 46.7 cm). There were no significant differences observed between conditions in peak force (1429.8 ± 289.1 N and 1453.7 ± 299.7 N, respectively). The results add to the growing body of literature describing the training and learning benefits of an external focus of attention. Practitioners should create standardized verbal instructions using an external focus of attention to maximize standing long jump performance.
Using Focus Groups to Validate a Pharmacy Vaccination Training Program.
Bushell, Mary; Morrissey, Hana; Ball, Patrick
2015-06-12
Introduction: Focus group methodology is commonly used to quickly collate, integrated views from a variety of different stakeholders. This paper provides an example of how focus groups can be employed to collate expert opinion informing amendments on a newly developed training program for integration into undergraduate pharmacy curricula. Materials and methods: Four focus groups were conducted, across three continents, to determine the appropriateness and reliability of a developed vaccination training program with nested injection skills training. All focus groups were comprised of legitimate experts in the field of vaccination, medicine and/or pharmacy. Results: Themes that emerged across focus groups informed amendments giving rise to a validated version of a training program. Discussion : The rigorous validation of the vaccination training program offers generalizable lessons to inform the design and validation of future training programs intended for the health sector and or pharmacy curricula. Using the knowledge and experience of focus group participants fostered collaborative problem solving and validation of material and concept development. The group dynamics of a focus group allowed synthesis of feedback in an inter-professional manner. Conclusions : This paper provides a demonstration of how focus groups can be structured and used by health researchers to validate a newly developed training program.
Focusing Electron Beams at SLAC.
ERIC Educational Resources Information Center
Taylor, Richard L.
1993-01-01
Describes the development of a set of magnets that focus high-energy electron and positron beams causing them to collide, annihilate each other, and generate new particles. Explains how dipoles bend the beam, how quadrupoles focus the beam, how the focal length is calculated, and the superconducting final focus. (MDH)
Apparatus and method for performing electrodynamic focusing on a microchip
Ramsey, John Michael; Jacobson, Stephen C.
1999-01-01
A microchip device includes a focusing channel, in which an electric field strength established in the focusing channel is controlled relative to an electric field strength established in a material transport channel segment to spatially focus the material traversing the material transport channel segment.
Spontaneous Focusing on Quantitative Relations: Towards a Characterization
ERIC Educational Resources Information Center
Degrande, Tine; Verschaffel, Lieven; Van Dooren, Wim
2017-01-01
In contrast to previous studies on Spontaneous Focusing on Quantitative Relations (SFOR), the present study investigated not only the "extent" to which children focus on (multiplicative) quantitative relations, but also the "nature" of children's quantitative focus (i.e., the types of quantitative relations that children focus…
Focus Groups Help To Focus the Marketing Strategy.
ERIC Educational Resources Information Center
Ashar, Hanna; Lane, Maureen
1996-01-01
A university-based degree completion program for adults conducted focus group research to refine market positioning and promotion. Focus groups averaged five current students and recent graduates who reflected, demographically, the current student population. Results gave insight into reasons for selecting the university, aspects of the program…
Microlens array for focusing airborne ultrasound using heated wire grid
NASA Astrophysics Data System (ADS)
Cai, Liang-Wu; Sánchez-Dehesa, José
2007-10-01
This letter reports on the focusing of airborne ultrasound by a simple grid of heated wires. The focusing is analogous to that of an array of optical microlenses. The focusing pattern is determined by the spacing between wires, and the focusing areas are tightly confined with a great "depth of field." Such acoustical microlens arrays have great potentials for shaping beams produced by ultrasonic transducers, in applications such as ultrasonic cleaning and nondestructive testing.
Fox, Mary T; Butler, Jeffrey I
2016-11-01
To explore nurses' perspectives on how leaders influence function-focused care, defined as care that preserves and restores older people's functional abilities. Hospitalised older people are at risk of functional decline. Although leaders have the potential to influence function-focused care, few studies have explored nurses' perspectives on how leaders influence function-focused care. Thirteen focus groups were held with 57 acute care nurses. Semi-structured questions prompted discussion on nurses' perspectives, needs and strategies to meet their needs. Data were thematically analysed. Three themes were identified: (1) the emphasis in hospitals is on moving older people quickly through the system, not supporting their functioning; (2) leaders are generally seen as too disconnected from practice to design system efficiency initiatives that support older people's functioning and nurses' provisioning of function-focused care; and (3) leadership strategies to better support nurses in providing function-focused care to older people in the context of system efficiency. Leaders should connect with practice to devise age-sensitive efficiency initiatives that support function-focused care. Nurses need support from leaders in four areas to provide function-focused care to older people in the current hospital context. The findings provide direction on how leaders can facilitate function-focused care in the current health-care environment emphasising system efficiency. © 2016 John Wiley & Sons Ltd.
Calatayud, Joaquin; Vinstrup, Jonas; Jakobsen, Markus D; Sundstrup, Emil; Colado, Juan Carlos; Andersen, Lars L
2018-05-01
The purpose of this study was to investigate whether using different focus affects electromyographic (EMG) amplitude and contraction duration during bench press performed at explosive and controlled speeds. Eighteen young male individuals were familiarized with the procedure and performed the one-maximum repetition (1RM) test in the first session. In the second session, participants performed the bench press exercise at 50% of the 1RM with 3 different attentional focuses (regular focus on moving the load vs contracting the pectoralis vs contracting the triceps) at 2 speed conditions (controlled vs maximal speed). During the controlled speed condition, focusing on using either the pectoralis or the triceps muscles increased pectoralis normalized EMG (nEMG) by 6% (95% CI 3-8%; p = 0.0001) and 4% nEMG (95% CI 1-7%; p = 0.0096), respectively, compared with the regular focus condition. Triceps activity was increased by 4% nEMG (95% CI 0-7%; p = 0.0308) at the controlled speed condition during the triceps focus. During the explosive speed condition, the use of different focuses had no effect. The different attentional focus resulted in comparable contraction duration for the measured muscles when the exercise was performed explosively. Using internal focus to increase EMG amplitude seems to function only during conditions of controlled speed.
[Analysis of palpation laws of muscle meridian focus on knee osteoarthritis].
Zhang, Shu-Jian; Zhang, Xiao-Qing; Han, Yu; Li, Chun-Ri; Dong, Bao-Qiang
2012-03-01
To explore the distribution regulars of proximal and distal focus of muscle meridian regions in knee osteoarthritis patients. Seven hundred and sixty-five knees were selected in 516 cases of knee osteoarthritis. Under the guidance of muscle meridian theory, with the anatomical features of muscle meridian focus, the frequency and the location where the proximal and distal focus of muscle meridian regions appeared were calculated by palpation. Of all the points, 11 835 points of proximal focus of muscle meridian regions were found out by palpation, and 9455 points of distal focus of muscle meridian regions were found out. The percentages of the frequency that the focus of muscle meridian of Foot-Yangming, Foot-Taiyang, Foot-Shaoyang and three foot Yin meridians appeared at proximal points of knee were 37.1% (4388/11 835), 34.9% (4127/11 835), 9.5% (1129/11 835) and 18.5% (2191/11 835) respectively; and the percentage of the frequency that the focus of muscle meridian appeared at distal points of knee were 24.7% (2333/9455), 25.2% (2380/9455), 28.5% (2700/9455) and 21.6% (2042/9455). The proximal and distal focus of muscle meridian in knee osteoarthritis patients are closely related with anatomy structure and biomechanical characteristics; the distribution regulars of focus of muscle meridians study provides evidence for the selection of effective treatment points from different clinical acupuncture therapies.
Escandón-García, Santiago; Ribeiro, Filomena J.; McAlinden, Colm
2018-01-01
Purpose To compare the through-focus visual performance in a clinical population of pseudophakic patients implanted with two new trifocal intraocular lenses (IOLs) and one extended depth of focus IOL. Methods Prospective, nonrandomized, examiner-masked case series. Twenty-three patients received the FineVision® and seven patients received the PanOptix™ trifocal IOLs. Fifteen patients received the Symfony extended depth of focus IOL. Mean age of patients was 63 ± 8 years. Through-focus visual acuity was measured from –3.00 to +1.00 D vergences. Contrast sensitivity was measured with and without a source of glare. Light disturbances were evaluated with the Light Distortion Analyzer. Results Though-focus evaluation showed that trifocal IOLs performed significantly better at near distance (33 and 40 cm), and extended depth of focus performed significantly better at intermediate distance (1.0 m). Contrast sensitivity function with glare and dysphotopsia was similar between the three IOLs and subjective response to questionnaire showed a significantly higher score (worse performance) for the extended depth of focus IOL compared to both trifocal IOLs in the bothersome subscale (p < 0.05). Conclusions Trifocal IOLs grant better performance at near distance while extended depth of focus IOL performs better at intermediate distance. Objective dysphotopsia measured with the Light Distortion Analyzer is not reduced in extended depth of focus IOL compared to trifocal IOLs. PMID:29651343
Flat Terahertz Reflective Focusing Metasurface with Scanning Ability.
Yi, Huan; Qu, Shi-Wei; Chen, Bao-Jie; Bai, Xue; Ng, Kung Bo; Chan, Chi Hou
2017-06-14
The ability to manipulate the propagation properties of electromagnetic waves, e.g., divergence, focusing, holography or deflection, is very significant in terahertz applications. Metasurfaces with flat structures are attractive for achieving such manipulations in terahertz band, as they feature low profile, lightweight, and ease of design and installation. Several types of terahertz reflective or transmitting metasurfaces with focusing function have been implemented recently, but none of them can provide scanning ability with controllable focus. Here, a flat reflective metasurface featuring controllable focal shift is proposed and experimentally demonstrated. Furthermore, the principle of designing a focus scanning reflective metasurface is presented and the focusing characteristics are discussed, including focus scanning along a line parallel or orthogonal to the metasurface with a large bandwidth. These interesting properties indicate that this flat reflective metasurface could play a key role in many terahertz imaging and detection systems.
Ruminative Self-Focus and Negative Affect
Moberly, Nicholas J.; Watkins, Edward R.
2008-01-01
The authors conducted an experience sampling study to investigate the relationship between momentary ruminative self-focus and negative affect. Ninety-three adults recorded these variables at quasi-random intervals 8 times daily for 1 week. Scores on questionnaire measures of dispositional rumination were associated with mean levels of momentary ruminative self-focus over the experience sampling week. Concurrently, momentary ruminative self-focus was positively associated with negative affect. Cross-lagged analyses revealed that whereas ruminative self-focus predicted negative affect at a subsequent occasion, negative affect also predicted ruminative self-focus at a subsequent occasion. Decomposition of the dispositional rumination measure suggested that brooding, but not reflective pondering, was associated with higher mean levels of negative affect. Though broadly consistent with Nolen-Hoeksema's (1991) response styles theory, these results suggest that a reciprocal relationship exists between ruminative self-focus and negative affect. PMID:18489207
A Field Experiment Testing the Utility of Regulatory Fit Messages for Promoting Physical Activity.
Latimer, Amy E; Rivers, Susan E; Rench, Tara A; Katulak, Nicole A; Hicks, Althea; Hodorowski, Julie Keany; Higgins, E Tory; Salovey, Peter
2008-05-01
Guided by regulatory focus theory, we examined whether messages tailored to individuals' promotion- or prevention-goal orientation (regulatory focus) elicit positive thoughts and feelings about physical activity and increase participation in physical activity. Inactive participants (N = 206) were assigned randomly to receive either promotion-focused or prevention-focused messages encouraging physical activity. Two weeks after message exposure, we assessed participants' thoughts and feelings about physical activity and physical activity behavior. Tailored messages that fit individuals' regulatory focus led to greater physical activity participation and more positive feelings than non-fit messages, particularly in the promotion-focused condition. Furthermore, positive retrospective feelings about physical activity mediated the effects of the tailored messages on behavior. These findings provide support for regulatory focus theory and direction for enhancing the effectiveness of messages encouraging physical activity and other health behaviors.
A Focusing Method in the Calibration Process of Image Sensors Based on IOFBs
Fernández, Pedro R.; Lázaro, José L.; Gardel, Alfredo; Cano, Ángel E.; Bravo, Ignacio
2010-01-01
A focusing procedure in the calibration process of image sensors based on Incoherent Optical Fiber Bundles (IOFBs) is described using the information extracted from fibers. These procedures differ from any other currently known focusing method due to the non spatial in-out correspondence between fibers, which produces a natural codification of the image to transmit. Focus measuring is essential prior to carrying out calibration in order to guarantee accurate processing and decoding. Four algorithms have been developed to estimate the focus measure; two methods based on mean grey level, and the other two based on variance. In this paper, a few simple focus measures are defined and compared. Some experimental results referred to the focus measure and the accuracy of the developed methods are discussed in order to demonstrate its effectiveness. PMID:22315526
Clinical responses to focused ultrasound applied to women with vulval intraepithelial neoplasia.
Jia, Ying; Wu, Jin; Xu, Man; Tang, Liangdan; Li, Chengzhi; Luo, Ming; Lou, Meng
2014-11-01
Focused ultrasound waves penetrate superficial tissues and are aimed toward the target tissues at specific depths to exert their biological effects. Focused ultrasound has been applied for a number of clinical indications, including vulval dystrophies and low-grade vulval disease. This study aimed to assess the efficacy and safety of focused ultrasound treatment of high-grade vulval intraepithelial neoplasia (VIN). Eighteen women with high-grade VIN were recruited and treated with focused ultrasound. During each posttreatment follow-up, the safety of, side effects of, and clinical responses to focused ultrasound were evaluated by a standardized protocol, including symptoms, clinical appearance, and histologic findings. All patients completed the designed follow-ups. In most cases, superficial mild to moderate swelling and blisters were seen in the focused ultrasound-treated skin but not in adjacent normal skin. Of the 18 patients, 16 showed complete histologic regression and resolution of symptoms 6 months after treatment. Of the other 2 patients, 1 showed complete regression after a second focused ultrasound treatment. The other patient did not respond to the focused ultrasound treatment and underwent a partial vulvectomy 6 months after treatment. None of the patients developed invasive carcinoma of the vulva during the follow-up period. One patient had local pruritus that was not alleviated by anti-inflammatory medication and local care. The complete responses observed in women with high-grade VIN treated by focused ultrasound, together with the preservation of adjacent normal tissue, suggest that focused ultrasound may be considered for treatment of high-grade VIN. © 2014 by the American Institute of Ultrasound in Medicine.
The use of focused ethnography in nursing research.
Cruz, Edward Venzon; Higginbottom, Gina
2013-03-01
To provide an overview of the relevance and strengths of focused ethnography in nursing research. The paper provides descriptions of focused ethnography and discusses using exemplars to show how focused ethnographies can enhance and understand nursing practice. Orthodox ethnographic approaches may not always be suitable or desirable for research in diverse nursing contexts. Focused ethnography has emerged as a promising method for applying ethnography to a distinct issue or shared experience in cultures or sub-cultures and in specific settings, rather than throughout entire communities. Unfortunately, there is limited guidance on using focused ethnography, particularly as applied to nursing research. Research studies performed by nurses using focused ethnography are summarised to show how they fulfilled three main purposes of the genre in nursing research. Additional citations are provided to help demonstrate the versatility of focused ethnography in exploring distinct problems in a specific context in different populations and groups of people. The unique role that nurses play in health care, coupled with their skills in enquiry, can contribute to the further development of the discipline. Focused ethnography offers an opportunity to gain a better understanding and appreciation of nursing as a profession, and the role it plays in society. Focused ethnography has emerged as a relevant research methodology that can be used by nurse researchers to understand specific societal issues that affect different facets of nursing practice. As nurse researchers endeavour to understand experiences in light of their health and life situations, focused ethnography enables them to understand the interrelationship between people and their environments in the society in which they live.
Predictors and enablers of mental health nurses' family-focused practice.
Grant, Anne; Reupert, Andrea; Maybery, Darryl; Goodyear, Melinda
2018-06-27
Family-focused practice improves outcomes for families where parents have a mental illness. However, there is limited understanding regarding the factors that predict and enable these practices. This study aimed to identify factors that predict and enable mental health nurses' family-focused practice. A sequential mixed methods design was used. A total of 343 mental health nurses, practicing in 12 mental health services (in acute inpatient and community settings), throughout Ireland completed the Family Focused Mental Health Practice Questionnaire, measuring family-focused behaviours and other factors that impact family-focused activities. Hierarchical multiple regression identified 14 predictors of family-focused practice. The most important predictors noted were nurses' skill and knowledge, own parenting experience, and work setting (i.e. community). Fourteen nurses, who achieved high scores on the questionnaire, subsequently participated in semistructured interviews to elaborate on enablers of family-focused practice. Participants described drawing on their parenting experiences to normalize parenting challenges, encouraging service users to disclose parenting concerns, and promoting trust. The opportunity to visit a service user's home allowed them to observe how the parent was coping and forge a close relationship with them. Nurses' personal characteristics and work setting are key factors in determining family-focused practice. This study extends current research by clearly highlighting predictors of family-focused practice and reporting how various enablers promoted family-focused practice. The capacity of nurses to support families has training, organizational and policy implications within adult mental health services in Ireland and elsewhere. © 2018 Australian College of Mental Health Nurses Inc.
Effects of Attentional Focus and Age on Suprapostural Task Performance and Postural Control
ERIC Educational Resources Information Center
McNevin, Nancy; Weir, Patricia; Quinn, Tiffany
2013-01-01
Purpose: Suprapostural task performance (manual tracking) and postural control (sway and frequency) were examined as a function of attentional focus, age, and tracking difficulty. Given the performance benefits often found under external focus conditions, it was hypothesized that external focus instructions would promote superior tracking and…
ERIC Educational Resources Information Center
Heldens, Henderijn; Bakx, Anouke; den Brok, Perry
2015-01-01
Teacher educators' collaboration plays an important role in the improvement of teacher education. Many studies in educational research focus on collaboration from 1 particular perspective. A focus on 2 perspectives, a qualitative (focusing on collaborative activities) as well as a quantitative (focusing on relations) perspective, and relating both…
The Purchasing Power of Collaboration
ERIC Educational Resources Information Center
Rosenthal, Amy; Mavrolas, Pamela; Rusmore, Barbara; Liquori, Toni
2017-01-01
Purpose/Objectives: School Food Focus (Focus) developed the Focus Midwest project on the premise that school food professionals (SFPs) could work together to minimize effort and maximize potential to find new or improved products to serve. Focus designed this project as an experiment to explore how and to what extent this collaborative approach…
21 CFR 312.86 - Focused FDA regulatory research.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 5 2014-04-01 2014-04-01 false Focused FDA regulatory research. 312.86 Section... Severely-debilitating Illnesses § 312.86 Focused FDA regulatory research. At the discretion of the agency, FDA may undertake focused regulatory research on critical rate-limiting aspects of the preclinical...
21 CFR 312.86 - Focused FDA regulatory research.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 5 2012-04-01 2012-04-01 false Focused FDA regulatory research. 312.86 Section... Severely-debilitating Illnesses § 312.86 Focused FDA regulatory research. At the discretion of the agency, FDA may undertake focused regulatory research on critical rate-limiting aspects of the preclinical...
21 CFR 312.86 - Focused FDA regulatory research.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 5 2011-04-01 2011-04-01 false Focused FDA regulatory research. 312.86 Section... Severely-debilitating Illnesses § 312.86 Focused FDA regulatory research. At the discretion of the agency, FDA may undertake focused regulatory research on critical rate-limiting aspects of the preclinical...
21 CFR 312.86 - Focused FDA regulatory research.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 5 2010-04-01 2010-04-01 false Focused FDA regulatory research. 312.86 Section... Severely-debilitating Illnesses § 312.86 Focused FDA regulatory research. At the discretion of the agency, FDA may undertake focused regulatory research on critical rate-limiting aspects of the preclinical...
A Feminist Critique of Solution-Focused Therapy.
ERIC Educational Resources Information Center
Dermer, Shannon B.; Hemesath, Crystal Wilhite; Russell, Candyce S.
1998-01-01
Applying the feminist critique to solution-focused therapy highlights the strengths and weaknesses of this model from a feminist perspective. Although solution-focused therapy and feminist approaches share an emphasis on competence and strengths, solution-focused theory tends to overlook gender and power differences. In general, the model falls…
42 CFR § 414.1465 - Physician-focused payment models.
Code of Federal Regulations, 2010 CFR
2017-10-01
... 42 Public Health 3 2017-10-01 2017-10-01 false Physician-focused payment models. § 414.1465... Merit-Based Incentive Payment System and Alternative Payment Model Incentive § 414.1465 Physician-focused payment models. (a) Definition. A physician-focused payment model (PFPM) is an Alternative Payment...
Assessment of Working Scientifically--The TAPS Focused Assessment Approach
ERIC Educational Resources Information Center
McMahon, Kendra
2018-01-01
The Teacher Assessment in Primary Science (TAPS) Focused Assessment approach embeds assessment within normal classroom science activities. Essentially, a Focused Assessment is a lesson plan for a science inquiry, with an identified focus for assessment and guidance on how to interpret the children's responses in relation to expectations for that…
The Semantics and Pragmatics of Japanese Focus Particles
ERIC Educational Resources Information Center
Hasegawa, Akio
2011-01-01
Japanese has a rich set of focus particles, several exclusive and additive particles, and, in addition, contrastive particles. This thesis provides a formal description of the meanings of Japanese focus particles and addresses two general questions: "What kinds concepts do Japanese focus particles express?" and "Why does Japanese have a larger…
Organizational and Spatial Dynamics of Attentional Focusing in Hierarchically Structured Objects
ERIC Educational Resources Information Center
Yeari, Menahem; Goldsmith, Morris
2011-01-01
Is the focusing of visual attention object-based, space-based, both, or neither? Attentional focusing latencies in hierarchically structured compound-letter objects were examined, orthogonally manipulating global size (larger vs. smaller) and organizational complexity (two-level structure vs. three-level structure). In a dynamic focusing task,…
Apparatus and method for performing electrodynamic focusing on a microchip
Ramsey, J.M.; Jacobson, S.C.
1999-01-12
A microchip device includes a focusing channel, in which an electric field strength established in the focusing channel is controlled relative to an electric field strength established in a material transport channel segment to spatially focus the material traversing the material transport channel segment. 22 figs.
Psychosocial Intervention for Age-Related Macular Degeneration: A Pilot Project
ERIC Educational Resources Information Center
Wahl, Hans-Werner; Kammerer, Annette; Holz, Frank; Miller, Daniel; Becker, Stefanie; Kaspar, Roman; Himmelsbach, Ines
2006-01-01
This study evaluated an emotion-focused and a problem-focused intervention designed for patients with age-related macular degeneration. It found a limited decrease in depression in the emotion-focused group and an increase in active problem orientation and in adaptation to vision loss in the problem-focused group.
21 CFR 312.86 - Focused FDA regulatory research.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 5 2013-04-01 2013-04-01 false Focused FDA regulatory research. 312.86 Section... Severely-debilitating Illnesses § 312.86 Focused FDA regulatory research. At the discretion of the agency, FDA may undertake focused regulatory research on critical rate-limiting aspects of the preclinical...
Focus on Student Success: Components for Effective Summer Bridge Programs
ERIC Educational Resources Information Center
Gonzalez Quiroz, Alicia; Garza, Nora R.
2018-01-01
Using research focused on best practices, focus group information, and data analytics, the Title V: Focus on Student Success (FOSS) Grant created a model for the development, implementation, and evaluation of a summer bridge program. Results included increased academic performance indicators in first-year Hispanic college students. Validation for…
Automatic focusing system of BSST in Antarctic
NASA Astrophysics Data System (ADS)
Tang, Peng-Yi; Liu, Jia-Jing; Zhang, Guang-yu; Wang, Jian
2015-10-01
Automatic focusing (AF) technology plays an important role in modern astronomical telescopes. Based on the focusing requirement of BSST (Bright Star Survey Telescope) in Antarctic, an AF system is set up. In this design, functions in OpenCV is used to find stars, the algorithm of area, HFD or FWHM are used to degree the focus metric by choosing. Curve fitting method is used to find focus position as the method of camera moving. All these design are suitable for unattended small telescope.
NASA Technical Reports Server (NTRS)
Bernacki, Bruce E.; Mansuripur, M.
1992-01-01
A commonly used tracking method on pre-grooved magneto-optical (MO) media is the push-pull technique, and the astigmatic method is a popular focus-error detection approach. These two methods are analyzed using DIFFRACT, a general-purpose scalar diffraction modeling program, to observe the effects on the error signals due to focusing lens misalignment, Seidel aberrations, and optical crosstalk (feedthrough) between the focusing and tracking servos. Using the results of the astigmatic/push-pull system as a basis for comparison, a novel focus/track-error detection technique that utilizes a ring toric lens is evaluated as well as the obscuration method (focus error detection only).
Removal of jitter noise in 3D shape recovery from image focus by using Kalman filter.
Jang, Hoon-Seok; Muhammad, Mannan Saeed; Choi, Tae-Sun
2018-02-01
In regard to Shape from Focus, one critical factor impacting system application is mechanical vibration of the translational stage causing jitter noise along the optical axis. This noise is not detectable by simply observing the image. However, when focus measures are applied, inaccuracies in the depth occur. In this article, jitter noise and focus curves are modeled by Gaussian distribution and quadratic function, respectively. Then Kalman filter is designed and applied to eliminate this noise in the focus curves, as a post-processing step after the focus measure application. Experiments are implemented with simulated objects and real objects to show usefulness of proposed algorithm. © 2017 Wiley Periodicals, Inc.
Microwave focusing with uniaxially symmetric gradient index metamaterials
NASA Astrophysics Data System (ADS)
Wheeland, Sara; Sternberg, Oren; Perez, Israel; Rockway, John D.
2016-09-01
Previous efforts to create a metamaterial lens in the microwave X band frequency range focused on the development of a device with biaxial symmetry. This allows for focusing solely along the central axis of propagation. For applications involving wave direction or energy diversion, focusing may be required off the central axis. This work explores a metamaterial device with uniaxial symmetry, namely in the direction of propagation. Ray-trace optimization and full-wave finite element simulations contribute to the design of the lens. By changing the placement of the focus, we achieve further control of the focus parameters. While the present work uses coils, the unit cell can consist of any structure or material.
Development of minimally invasive surgery for intractable epilepsy
NASA Astrophysics Data System (ADS)
Yamakawa, Takeshi
2009-04-01
Epilepsy is a chronic brain disorder characterized by recurrent seizures. The seizure is shot down by the surgical removal of the region which is so called "epileptogenc focus". However, the accuracy to detect the focus is not good (order of cm). Thus the extirpation of focus with significant margin causes the removal of normal brain and leads to the severe aftereffects such as restricted vision, motor dysfunction, disorder of memory, and so on. To cope with this problem, we should develop the technology of (1) detecting the epileptogenic focus, and (2) necrotizing the epileptogenic focus excluding normal brain by (a) colliquative necrosis with flash freezing and melting or (b) cauterizing by focused laser beam.
It could have been me: vicarious victims and disaster-focused distress.
Wayment, Heidi A
2004-04-01
College students who had experienced no personal bereavement in the September 11 terrorist attacks completed questionnaires between 3 and 5 weeks after the attacks and 5 months later. Cross-sectional and longitudinal structural equation model (SEM) analyses revealed that general distress and disaster-focused distress are discernable reactions following a collective loss. Both types of distress were higher among women and by those reporting social strain. General distress was associated with previous stressful events and mental health issues. Perceived similarity to the victims predicted disaster-focused distress and mediated the relationship between attending to media accounts of victims and disaster-focused distress. Only the disaster-focused distress reactions of survivor guilt and grief were associated with collective helping behaviors after the attacks and, for women, these behaviors were associated with greater reductions in these distress reactions over time. Discussion focuses on the importance of examining disaster-focused distress reactions following collective loss.
Ellipsoid-conic radiation collector and method
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brunsting, A.; Hogg, W.R.
Disclosed is a radiation collector apparatus and method primarily for counting and analyzing a flow of dilute particulate material, such as blood cells, sperm cells and the like, through the use of light detection. The radiation collector apparatus comprises a reflector chamber having an ellipsoidal reflector surface with a pair of elipsoidal foci defining a first focus, f11, and second focus, f12, and a second reflector surface with a primary focus, f21, positioned at the same point as focus f12, and a secondary focus, f22. The second reflector surface has the configuration of one of the conic sections of revolution.more » In operation the radiation collector apparatus is provided with an intensifed beam of light and a stream of particulate material aligned to intersect the intensifed beam of light at focus f11. Detectable light signals, after two reflections, are received in a focused beam by a photosensitive detector.« less
Depressive Symptoms and Conversational Self-Focus in Adolescents’ Friendships
Schwartz-Mette, Rebecca A.; Rose, Amanda J.
2015-01-01
This multi-method, longitudinal study considered the interplay among depressive symptoms, aversive interpersonal behavior, and interpersonal rejection in early and middle adolescents’ friendships. In particular, the study examined a newly identified interpersonal process, conversational self-focus (i.e., the tendency to redirect conversations about problems to focus on the self). Traditional interpersonal theories of depression suggest that individuals with depressive symptoms engage in aversive behaviors (such as conversational self-focus) and are rejected by others. However, in the current study, not all adolescents with depressive symptoms engaged in conversational self-focus and were rejected by friends. Instead, conversational self-focus moderated prospective relations of depressive symptoms and later friendship problems such that only adolescents with depressive symptoms who engaged in conversational self-focus were rejected by friends. These findings are consistent with current conceptualizations of the development of psychopathology that highlight heterogeneity among youth who share similar symptoms and the possibility of multifinality of outcomes. PMID:25640911
Age, task complexity, and sex as potential moderators of attentional focus effects.
Becker, Kevin; Smith, Peter J K
2013-08-01
The study tested whether age, sex, or task complexity moderate the effect of attentional focus on motor learning. Children (24 boys, 24 girls) and adults (24 men, 24 women) were assigned to an internal or external attentional focus, and were timed while riding either a Double Pedalo with handles (simple task) or without handles (complex task) over a distance of 7 meters. A Double Pedalo is a four-wheeled device that involves standing on two connected platforms, and alternately pushing them forward to make it move. Participants completed 20 acquisition trials, followed by a 24-hour retention test. For the simpler task, no time differences due to attentional focus emerged. With the complex task, an external focus resulted in faster times in retention than an internal focus, but only for males. These findings suggest that attentional focus affects children and adults similarly, but task complexity and sex moderate these effects.
Tausch, Anja P; Menold, Natalja
2016-01-01
Although focus groups are commonly used in health research to explore the perspectives of patients or health care professionals, few studies consider methodological aspects in this specific context. For this reason, we interviewed nine researchers who had conducted focus groups in the context of a project devoted to the development of an electronic personal health record. We performed qualitative content analysis on the interview data relating to recruitment, communication between the focus group participants, and appraisal of the focus group method. The interview data revealed aspects of the focus group method that are particularly relevant for health research and that should be considered in that context. They include, for example, the preferability of face-to-face recruitment, the necessity to allow participants in patient groups sufficient time to introduce themselves, and the use of methods such as participant-generated cards and prioritization.
NASA Astrophysics Data System (ADS)
Tseng, Snow H.; Chang, Shih-Hui
2018-04-01
Here we present a numerical simulation to analyze the effect of scattering on focusing light into closely-spaced twin peaks. The pseudospectral time-domain (PSTD) is implemented to model continuous-wave (CW) light propagation through a scattering medium. Simulations show that CW light can propagate through a scattering medium and focus into closely-spaced twin peaks. CW light of various wavelengths focusing into twin peaks with sub-diffraction spacing is simulated. In advance, light propagation through scattering media of various number densities is simulated to decipher the dependence of CW light focusing phenomenon on the scattering medium. The reported simulations demonstrate the feasibility of focusing CW light into twin peaks with sub-diffraction dimensions. More importantly, based upon numerical solutions of Maxwell’s equations, research findings show that the sub-diffraction focusing phenomenon can be achieved with scarce or densely-packed scattering media.
Focus Group Evidence: Implications for Design and Analysis
ERIC Educational Resources Information Center
Ryan, Katherine E.; Gandha, Tysza; Culbertson, Michael J.; Carlson, Crystal
2014-01-01
In evaluation and applied social research, focus groups may be used to gather different kinds of evidence (e.g., opinion, tacit knowledge). In this article, we argue that making focus group design choices explicitly in relation to the type of evidence required would enhance the empirical value and rigor associated with focus group utilization. We…
Dual Identities: Organizational Negotiation in STEM-Focused Catholic Schools
ERIC Educational Resources Information Center
Kloser, Matthew; Wilsey, Matthew; Hopkins, Dawn W.; Dallavis, Julie W.; Lavin, Erin; Comuniello, Michael
2018-01-01
In the last decade, STEM-focused schools have opened their doors nationally in the hope of meeting students' contemporary educational needs. Despite the growth of these STEM-focused institutions, minimal research exists that follows how schools make a transition toward a STEM focus and what organizational structures are most conducive to a…
Alternating phase focused linacs
Swenson, Donald A.
1980-01-01
A heavy particle linear accelerator employing rf fields for transverse and ongitudinal focusing as well as acceleration. Drift tube length and gap positions in a standing wave drift tube loaded structure are arranged so that particles are subject to acceleration and succession of focusing and defocusing forces which contain the beam without additional magnetic or electric focusing fields.
ERIC Educational Resources Information Center
Hyten, Cloyd
2009-01-01
Current Organizational Behavior Management (OBM) research and practice may be characterized as either behavior focused or results focused. These two approaches stem from different origins and have different characteristics. The behavior-focused approach stems from applied behavior analysis (ABA) methods and emphasizes direct observation of and…
ERIC Educational Resources Information Center
Owen, Margaret Tresch; Klausli, Julia F.; Mata-Otero, Ana-Maria; Caughy, Margaret O'Brien
2008-01-01
Research Findings: Child care delivery practices promoting continuous, primary caregiver-child relationships (relationship-focused child care) were evaluated for 223 preschool-age children (45% African American, 55% Latino) attending child care centers serving low-income children. Both relationship-focused and non-relationship-focused centers were…
Copper Gas Diffusers For Purging Line-Focus Laser Welds
NASA Technical Reports Server (NTRS)
Fonteyne, Steve L.; Hosking, Timothy J.; Shelley, D. Mark
1996-01-01
Modified flow diffusers built for inert-gas purging of welds made with 5-kW CO(2) lasers operating with line-focus optics in conduction mode instead of with point-focus optics in customary keyhole mode. Diffusers made of copper components brazed together, robust enough to withstand strong reflections of line-focused laser energy.
76 FR 14374 - Proposed Information Collection for Focus Groups and One-on-One Interviews
Federal Register 2010, 2011, 2012, 2013, 2014
2011-03-16
... DEPARTMENT OF COMMERCE Proposed Information Collection for Focus Groups and One-on-One Interviews... comments on Proposed Information Collection for Focus Groups and One-on-one Interviews for the Elwha River... Collection (IC) to conduct focus groups and one-on-one interviews, described below. We invite the general...
Time reversal focusing of elastic waves in plates for an educational demonstration.
Heaton, Christopher; Anderson, Brian E; Young, Sarah M
2017-02-01
The purpose of this research is to develop a visual demonstration of time reversal focusing of vibrations in a thin plate. Various plate materials are tested to provide optimal conditions for time reversal focusing. Specifically, the reverberation time in each plate and the vibration coupling efficiency from a shaker to the plate are quantified to illustrate why a given plate provides the best spatially confined focus as well as the highest focal amplitude possible. A single vibration speaker and a scanning laser Doppler vibrometer (SLDV) are used to provide the time reversal focusing. Table salt is sprinkled onto the plate surface to allow visualization of the high amplitude, spatially localized time reversal focus; the salt is thrown upward only at the focal position. Spatial mapping of the vibration focusing on the plate using the SLDV is correlated to the visual salt jumping demonstration. The time reversal focusing is also used to knock over an object when the object is placed at the focal position; some discussion of optimal objects to use for this demonstration are given.
Acoustic Correlates of Focus Marking in Czech and Polish.
Hamlaoui, Fatima; Żygis, Marzena; Engelmann, Jonas; Wagner, Michael
2018-05-01
Languages vary in the type of contexts that affect prosodic prominence. This paper reports on a production study investigating how different types of foci influence prosody in Polish and Czech noun phrases. The results show that in both languages, focus and givenness are marked prosodically, with pitch and intensity as the main acoustic correlates. Like Germanic languages, Polish and Czech patterns show prosodic focus marking in a broad range of contexts and differ in this regard from other fixed-word-stress languages such as French. This suggests that (a) Polish and Czech are similar to Germanic languages and are unlike Romance languages in marking a variety of types of focus prosodically; (b) there is no close correlation between fixed word stress and lack of prosodic focus marking because Polish, which has fixed stress on the penult, shows prosodic focus marking for all types of focus; and (c) there is no straightforward relationship between flexible word order and whether focus and givenness are prosodically marked, contrary to earlier claims, because both Czech and Polish, with their relatively flexible word order, are more similar to English than Romance languages.
Slater, Amy; Halliwell, Emma; Jarman, Hannah; Gaskin, Emma
2017-09-01
In recent years, elements of the modern environment (such as television, Internet, toys and clothes) have been criticized for having an increasingly sexualized or appearance focus, which has been suggested to be detrimental to girls' development. The current study examined the impact of an appearance-focused Internet game on young girls' body image and career cognitions and aspirations. Eighty British girls aged 8-9 years were randomly assigned to play an appearance-focused or a non-appearance focused game for 10 minutes. Girls in the appearance-focused game condition displayed greater body dissatisfaction compared to the control condition. Type of game did not impact girls' perceived capacity to do various jobs. However, girls who played the appearance-focused game reported a greater preference for feminine careers compared to the control group. This provides preliminary evidence that appearance-focused Internet games may be detrimental to young girls' body image and aspirations. Internet games should be included in our consideration of influential messages for young girls.
Kong, Peiling; Harris, Lynne M
2015-01-01
Female athletes experience pressure to conform to social and sporting norms concerning body weight. This study compared general and sporting body dissatisfaction and disordered eating symptomatology among 320 elite, recreational, and noncompetitive female athletes aged 17 to 30 years competing in leanness focused sports and nonleanness focused sports. Participants completed an online questionnaire including demographic questions, the Eating Attitudes Test, and the Figure Rating Scale. Athletes from leanness focused sports reported higher levels of body dissatisfaction and greater disordered eating symptomatology regardless of participation level. Elite athletes reported higher levels of body dissatisfaction and greater disordered eating symptomatology regardless of sport type, and differences between recreational and noncompetitive athletes were not found. More than 60% of elite athletes from leanness focused and nonleanness focused sports reported pressure from coaches concerning body shape. The findings have important implications for identifying risk factors for eating disorders among female athletes, where athletes who compete at elite level and those who compete in leanness focused sports at any level may be at higher risk for developing eating disorders.
Wave-optical assessment of alignment tolerances in nano-focusing with ellipsoidal mirror
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yumoto, Hirokatsu, E-mail: yumoto@spring8.or.jp; Koyama, Takahisa; Matsuyama, Satoshi
2016-01-28
High-precision ellipsoidal mirrors, which can efficiently focus X-rays to the nanometer dimension with a mirror, have not been realized because of the difficulties in the fabrication process. The purpose of our study was to develop nano-focusing ellipsoidal mirrors in the hard X-ray region. We developed a wave-optical focusing simulator for investigating alignment tolerances in nano-focusing with a designed ellipsoidal mirror, which produce a diffraction-limited focus size of 30 × 35 nm{sup 2} in full width at half maximum at an X-ray energy of 7 keV. The simulator can calculate focusing intensity distributions around the focal point under conditions of misalignment. Themore » wave-optical simulator enabled the calculation of interference intensity distributions, which cannot be predicted by the conventional ray-trace method. The alignment conditions with a focal length error of ≲ ±10 µm, incident angle error of ≲ ±0.5 µrad, and in-plane rotation angle error of ≲ ±0.25 µrad must be satisfied for nano-focusing.« less
Changes in the dark focus of accommodation associated with simulator sickness
NASA Technical Reports Server (NTRS)
Fowlkes, Jennifer E.; Kennedy, Robert S.; Hettinger, Lawrence J.; Harm, Deborah L.
1993-01-01
The relationship between the dark focus of accommodation and simulator sickness, a form of motion sickness, was examined in three experiments. In Experiment 1, dark focus was measured in 18 college students in a laboratory setting before and after they viewed a projected motion scene depicting low altitude helicopter flight. In Experiments 2 and 3, dark focus was measured in pilots (N = 16 and 23, respectively) before and after they 'flew' in moving-base helicopter flight simulators with optical infinity CRT visual systems. The results showed that individuals who experienced simulator sickness had either an inward (myopic) change in dark focus (Experiments 1 and 3) or attenuated outward shifts in dark focus (Experiment 2) relative to participants who did not get sick. These results are consonant with the hypothesis that parasympathetic activity, which may be associated with simulator sickness, should result in changes in dark focus that are in a myopic direction. Night vision goggles, virtual environments, extended periods in microgravity, and heads-up displays all produce related visual symptomatology. Changes in dark focus may occur in these conditions, as well, and should be measured.
Focused ultrasound in ophthalmology
Silverman, Ronald H
2016-01-01
The use of focused ultrasound to obtain diagnostically significant information about the eye goes back to the 1950s. This review describes the historical and technological development of ophthalmic ultrasound and its clinical application and impact. Ultrasound, like light, can be focused, which is crucial for formation of high-resolution, diagnostically useful images. Focused, single-element, mechanically scanned transducers are most common in ophthalmology. Specially designed transducers have been used to generate focused, high-intensity ultrasound that through thermal effects has been used to treat glaucoma (via ciliodestruction), tumors, and other pathologies. Linear and annular transducer arrays offer synthetic focusing in which precise timing of the excitation of independently addressable array elements allows formation of a converging wavefront to create a focus at one or more programmable depths. Most recently, linear array-based plane-wave ultrasound, in which the array emits an unfocused wavefront and focusing is performed solely on received data, has been demonstrated for imaging ocular anatomy and blood flow. While the history of ophthalmic ultrasound extends back over half-a-century, new and powerful technologic advances continue to be made, offering the prospect of novel diagnostic capabilities. PMID:27757007
Focused ultrasound in ophthalmology.
Silverman, Ronald H
2016-01-01
The use of focused ultrasound to obtain diagnostically significant information about the eye goes back to the 1950s. This review describes the historical and technological development of ophthalmic ultrasound and its clinical application and impact. Ultrasound, like light, can be focused, which is crucial for formation of high-resolution, diagnostically useful images. Focused, single-element, mechanically scanned transducers are most common in ophthalmology. Specially designed transducers have been used to generate focused, high-intensity ultrasound that through thermal effects has been used to treat glaucoma (via ciliodestruction), tumors, and other pathologies. Linear and annular transducer arrays offer synthetic focusing in which precise timing of the excitation of independently addressable array elements allows formation of a converging wavefront to create a focus at one or more programmable depths. Most recently, linear array-based plane-wave ultrasound, in which the array emits an unfocused wavefront and focusing is performed solely on received data, has been demonstrated for imaging ocular anatomy and blood flow. While the history of ophthalmic ultrasound extends back over half-a-century, new and powerful technologic advances continue to be made, offering the prospect of novel diagnostic capabilities.
NASA Astrophysics Data System (ADS)
Ab Hamid, Mohd Rashid; Mustafa, Zainol; Mohd Suradi, Nur Riza; Idris, Fazli; Abdullah, Mokhtar
2013-04-01
Culture and employee-focused criteria are important factors for the success of any organization. These factors have to be aligned with the productivity initiatives in the organization in order to gear ahead for excellence. Therefore, this article investigated the impact of culture and employee-focused criteria on productivity in Higher Education Institutions (HEIs) in Malaysia using intangible indicators through core values. The hypothesized relationship was tested using Structural Equation Modeling (SEM) with the PLS estimation technique. 429 questionnaires were returned from the target population. The results of the modelling revealed that the PLS estimation confirmed all the hypotheses tested as in the hypothesized model. The results generally support significant relationships between culture values, employee-focused values and productivity-focused values. The study also confirmed the mediating role of employee-focused values for the relationship between culture values and productivity-focused values. In conclusion, the empirically validated results supported the adequacy of the hypothezised model of the impact of culture and employee-focused criteria on productivity in HEI through value-based indicators.
Non-toric extended depth of focus contact lenses for astigmatism and presbyopia correction
NASA Astrophysics Data System (ADS)
Ben Yaish, Shai; Zlotnik, Alex; Yehezkel, Oren; Lahav-Yacouel, Karen; Belkin, Michael; Zalevsky, Zeev
2010-02-01
Purpose: Testing whether the extended depth of focus technology embedded on non-toric contact lenses is a suitable treatment for both astigmatism and presbyopia. Methods: The extended depth of focus pattern consisting of microndepth concentric grooves was engraved on a surface of a mono-focal soft contact lens. These grooves create an interference pattern extending the focus from a point to a length of about 1mm providing a 3.00D extension in the depth of focus. The extension in the depth of focus provides high quality focused imaging capabilities from near through intermediate and up to far ranges. Due to the angular symmetry of the engraved pattern the extension in the depth of focus can also resolve regular as well as irregular astigmatism aberrations. Results: The contact lens was tested on a group of 8 astigmatic and 13 subjects with presbyopia. Average correction of 0.70D for astigmatism and 1.50D for presbyopia was demonstrated. Conclusions: The extended depth of focus technology in a non-toric contact lens corrects simultaneously astigmatism and presbyopia. The proposed solution is based upon interference rather than diffraction effects and thus it is characterized by high energetic efficiency to the retina plane as well as reduced chromatic aberrations.
Gâteau, Jérôme; Marsac, Laurent; Pernot, Mathieu; Aubry, Jean-Francois; Tanter, Mickaël; Fink, Mathias
2010-01-01
Brain treatment through the skull with High Intensity Focused Ultrasound (HIFU) can be achieved with multichannel arrays and adaptive focusing techniques such as time-reversal. This method requires a reference signal to be either emitted by a real source embedded in brain tissues or computed from a virtual source, using the acoustic properties of the skull derived from CT images. This non-invasive computational method focuses with precision, but suffers from modeling and repositioning errors that reduce the accessible acoustic pressure at the focus in comparison with fully experimental time-reversal using an implanted hydrophone. In this paper, this simulation-based targeting has been used experimentally as a first step for focusing through an ex vivo human skull at a single location. It has enabled the creation of a cavitation bubble at focus that spontaneously emitted an ultrasonic wave received by the array. This active source signal has allowed 97%±1.1% of the reference pressure (hydrophone-based) to be restored at the geometrical focus. To target points around the focus with an optimal pressure level, conventional electronic steering from the initial focus has been combined with bubble generation. Thanks to step by step bubble generation, the electronic steering capabilities of the array through the skull were improved. PMID:19770084
Variable magnification glancing incidence x ray telescope
NASA Technical Reports Server (NTRS)
Hoover, Richard (Inventor)
1990-01-01
A multispectral glancing incidence x ray telescope is disclosed, which capable of broadband, high resolution imaging of solar and stellar x ray and extreme ultraviolet radiation sources includes a primary optical system which focuses the incoming radiation to a primary focus. Two or more ellipsoidal mirrors are positioned behind the primary focus at an inclination to the optical axis, each mirror having a concave surface coated with a multilayer synthetic microstructure coating to reflect a desired wavelength. The ellipsoidal mirrors are segments of respective ellipsoids having a common first focus coincident with the primary focus. A detector such as an x ray sensitive photographic film is positioned at the second focus of each of the ellipsoids so that each of the ellipsoidal mirrors may reflect the image at the first focus to the detector. In one embodiment the mirrors are inclined at different angles and has its respective second focus at a different location, separate detectors being located at the respective second focus. The mirrors are arranged so that the magnification and field of view differ, and a solenoid activated arm may withdraw at least one mirror from the beam to select the mirror upon which the beam is to impinge so that selected magnifications and fields of view may be detected.
Hyperkahler metrics on focus-focus fibrations
NASA Astrophysics Data System (ADS)
Zhao, Jie
In this thesis, we focus on the study of hyperkahler metric in four dimensional cases, and practice GMN's construction of hyperkahler metric on focus-focus fibrations. We explicitly compute the action-angle coordinates on the local model of focus-focus fibration, and show its semi-global invariant should be harmonic to admit a compatible holomorphic 2-form. Then we study the canonical semi-flat metric on it. After the instanton correction inspired by physics, we get a family of the generalized Ooguri-Vafa metric on focus-focus fibrations, which becomes more local examples of explicit hyperkahler metric in four dimensional cases. In addition, we also make some exploration of the Ooguri-Vafa metric in the thesis. We study the potential function of the Ooguri-Vafa metric, and prove that its nodal set is a cylinder of bounded radius 1 < R < 1. As a result, we get that only on a finite neighborhood of the singular fibre the Ooguri-Vafa metric is a hyperkahler metric. Finally, we give some estimates for the diameter of the fibration under the Oogui-Vafa metric, which confirms that the Oogui-Vafa metric is not complete. The new family of metric constructed in the thesis, we think, will provide more examples to further study of Lagrangian fibrations and mirror symmetry in future.
Cheung, Tracy T. L.; Gillebaart, Marleen; Kroese, Floor; De Ridder, Denise
2014-01-01
Background: While self-control has often been related to positive outcomes in life such as higher academic achievements and better health, recent insights reveal that people with high trait self-control (TSC) may even experience greater life satisfaction or happiness. Objective: The current study further scrutinizes this potential association between TSC and happiness, and examines how regulatory focus, defined as the way people frame and direct their goal pursuit strategies, plays a role in this relationship. Accordingly, the present study examines the mediating role of regulatory-focus (promotion and prevention focus) on the relationship between TSC and happiness. Method: Data was collected from 545 individuals (65.9% female, Mage = 27.52 years) regarding their TSC, regulatory focus, and happiness. Results: Mediation analyses demonstrate that TSC positively predicts happiness, while this effect was partially mediated by relatively more promotion focus and less prevention focus. Conclusion: Results suggest that people with higher TSC are happier possibly because they are: (1) more promotion-focused on acquiring positive gains thereby facilitating more approach-oriented behaviors, and (2) less prevention-focused on avoiding losses thereby reducing avoidance-oriented behaviors. These findings are relevant for topical scientific debates regarding the underlying mechanisms of self-control regarding initiatory and inhibitory behaviors. PMID:25071683
An external focus of attention enhances balance learning in older adults.
Chiviacowsky, Suzete; Wulf, Gabriele; Wally, Raquel
2010-10-01
Studies with young adults have shown that an external focus of attention (i.e., on the movement effect) results in more effective motor learning and greater automaticity than an internal focus (i.e., on one's own body movements). The present study examined whether instructions inducing an external versus internal attentional focus would differentially affect the learning of a balance task in 32 older adults (24 females and 8 males, mean age: 69.4 years), divided equally, by number and gender, into two groups. The task required participants to stand on a balance platform (stabilometer) tilting to the left and right, and to try to keep the platform as close to horizontal as possible during each 30-s trial. The external focus group was instructed to concentrate on keeping markers on the platform horizontal, while the internal focus group was instructed to concentrate on keeping their feet horizontal. The dependent variable was time in balance (i.e., platform movements within ± 5°). Participants performed 10 practice trials on day 1, with focus reminders given before each trial. Learning was assessed by a retention test, consisting of five trials without instructions, performed 1 day later. The external focus group outperformed the internal focus group in retention [F(4, 120)=3.46, p=.01]. The results demonstrate that the learning benefits of an external attentional focus are generalizable to older learners. Copyright © 2010 Elsevier B.V. All rights reserved.
A numerical study on the oblique focus in MR-guided transcranial focused ultrasound
NASA Astrophysics Data System (ADS)
Hughes, Alec; Huang, Yuexi; Pulkkinen, Aki; Schwartz, Michael L.; Lozano, Andres M.; Hynynen, Kullervo
2016-11-01
Recent clinical data showing thermal lesions from treatments of essential tremor using MR-guided transcranial focused ultrasound shows that in many cases the focus is oblique to the main axis of the phased array. The potential for this obliquity to extend the focus into lateral regions of the brain has led to speculation as to the cause of the oblique focus, and whether it is possible to realign the focus. Numerical simulations were performed on clinical export data to analyze the causes of the oblique focus and determine methods for its correction. It was found that the focal obliquity could be replicated with the numerical simulations to within 23.2+/- {{13.6}\\circ} of the clinical cases. It was then found that a major cause of the focal obliquity was the presence of sidelobes, caused by an unequal deposition of power from the different transducer elements in the array at the focus. In addition, it was found that a 65% reduction in focal obliquity was possible using phase and amplitude corrections. Potential drawbacks include the higher levels of skull heating required when modifying the distribution of power among the transducer elements, and the difficulty at present in obtaining ideal phase corrections from CT information alone. These techniques for the reduction of focal obliquity can be applied to other applications of transcranial focused ultrasound involving lower total energy deposition, such as blood-brain barrier opening, where the issue of skull heating is minimal.
The performance of magnetic lens for focusing VCN-SANS
NASA Astrophysics Data System (ADS)
Nop Collaboration; Yamada, M.; Iwashita, Y.; Kanaya, T.; Ichikawa, M.; Tongu, H.; Kennedy, S. J.; Shimizu, H. M.; Mishima, K.; Yamada, N. L.; Hirota, K.; Carpenter, J. M.; Lal, J.; Andersen, K.; Geltenbort, P.; Guerard, B.; Manzin, G.; Hino, M.; Kitaguchi, M.; Bleuel, M.; NOP Collaboration
2011-04-01
We have developed a prototype rotating-permanent magnet sextupole lens (named rot-PMSx) for more efficient experiments with neutron beams in time of flight (ToF) mode. This lens can modulate the focusing strength over range 1.5×104T/m2⩽g‧⩽5.9×104T/m2. Synchronization between the modulation and the beam pulse produces a focused beam without significant chromatic aberration. We anticipate that this lens could be utilized in focusing small angle neutron scattering (SANS) instruments for novel approach to high resolution SANS.We carried out experiments testing the principle of this lens at the very cold neutron (VCN) beamline (PF2) at Institut Laue-Langevin (ILL), France. The focused beam image size at the detector was kept constant at the same beam size as the source (≈3mm) over a wavelength range of 30Å⩽λ⩽48Å in focal length of ≈1.14m. The flux gain was about 12 relative to a beam without focusing, and the depth of focus was quite large. These results show the good performance of this lens and the system. Thereupon we have demonstrated the performance of this test bed for high resolution focusing of VCN-SANS for a well-studied softmatter sample; a deuterium oxide solution of Pluronic F127, an (PEO)100(PPO)65(PEO)100 tri-block copolymer in deuterium oxide. The results of the focusing experiment and the focusing VCN-SANS are presented.
Pelleck, Valerie; Passmore, Steven R
2017-05-01
Impaired performance while executing a motor task is attributed to a disruption of normal automatic processes when an internal focus of attention is used. What remains unclear is whether the specificity of internally focused task instructions may impact task performance. The present study assessed the implications of changing the attentional focus of novice and skilled golfers by measuring behavioural, neurophysiological and kinematic changes during a golf putting task. Over six blocks of ten putting trials each, attention was directed either externally (towards the target) or internally in one of two ways: 1) proximal (keeping the elbows extended and the hands gripping the putter); or 2) distal (keeping the weight evenly distributed between both legs) to the critical elements of the task. Results provided evidence that when novice participants use an internal focus of attention more closely associated with task performance that their: 1) execution; 2) accuracy; 3) variability of surface electromyography (sEMG) activity; and 4) kinematics of the putter movement are all adversely affected. Skilled golfers are much more resilient to changes in attentional focus, while all participants interpret a distal internal focus of attention similar to an external focus. All participants produced decreased activity in the muscle (tibialis anterior) associated with the distal (less task relevant) focus of attention even when the "internal" focus was on the lower extremity. Our results provide evidence that the skill level of the participant and the distance of the internal focus of attention from the key elements of a motor skill directly impact the execution, muscle activity, and movement kinematics associated with skilled motor task performance. Copyright © 2017 Elsevier B.V. All rights reserved.
Jarus, Tal; Ghanouni, Parisa; Abel, Rachel L; Fomenoff, Shelby L; Lundberg, Jocelyn; Davidson, Stephanie; Caswell, Sarah; Bickerton, Laura; Zwicker, Jill G
2015-02-01
Children with developmental coordination disorder (DCD) struggle to learn new motor skills. It is unknown whether children with DCD learn motor skills more effectively with an external focus of attention (focusing on impact of movement on the environment) or an internal focus of attention (focusing on one's body movements) during implicit (unconscious) and explicit (conscious) motor learning. This paper aims to determine the trends of implicit motor learning in children with DCD, and how focus of attention influences motor learning in children with DCD in comparison with typically developing children. 25 children, aged 8-12, with (n=12) and without (n=13) DCD were randomly assigned to receive instructions that focused attention externally or internally while completing a computer tracking task during acquisition, retention, and transfer phases. The motor task involved tracking both repeated and random patterns, with the repeated pattern indicative of implicit learning. Children with DCD scored lower on the motor task in all three phases of the study, demonstrating poorer implicit learning. Furthermore, graphical data showed that for the children with DCD, there was no apparent difference between internal and external focus of attention during retention and transfer, while there was an advantage to the external focus of attention group for typically developing children. Children with DCD demonstrate less accuracy than typically developing children in learning a motor task. Also, the effect of focus of attention on motor performance is different in children with DCD versus their typically developing counterparts during the three phases of motor learning. Results may inform clinicians how to facilitate motor learning in children with DCD by incorporating explicit learning with either internal or external focus of attention within interventions. Copyright © 2014 Elsevier Ltd. All rights reserved.
Patient focused care team design. Critical aspects of a cost-effective design strategy.
Leander, W J
1993-01-01
It is the critical, yet largely unknown aspects of Patient Focused care team design--the "how" of a design process--which make LRMC's "Care Pairs" a ground-breaking innovation rather than just a distinctive-sounding name. Unfortunately, many hospital leaders of Patient Focused Care programs know the "what" of LRMC's "Care Pairs" but very little, if anything, about this "how." To create Patient Focused care teams which are "right" for your own institution, you must quantify the Costs of Continuity, Competency and Compartmentalization and their associated benefits. Without these informed trade-offs, you and your hospital will be forced to live with someone else's Patient Focused care team design. In summary, it is what you don't know about LRMC's "Care Pairs," not what you do know, that is important to your Patient Focused Care program. Hospitals just beginning to implement Patient Focused Care must understand this "how" if they are to design effective care teams which optimize the performance of their initial unit(s) within their unique environments. Hospitals like LRMC with established Patient Focused Care units must also periodically draw upon this "how" or they face the very real danger of having their Patient Focused care team design(s) become outdated, less effective and eventually detrimental. Or, said another way: "The man who does not read good books has no advantage over those who cannot." Mark Twain. "An out-of-date Patient Focused hospital has no advantage over those which remain unrestructured." The PFCA. The three critical aspects of Patient Focused care team design explored in this article are just the tip of the iceberg.(ABSTRACT TRUNCATED AT 250 WORDS)
High-speed image processing system and its micro-optics application
NASA Astrophysics Data System (ADS)
Ohba, Kohtaro; Ortega, Jesus C. P.; Tanikawa, Tamio; Tanie, Kazuo; Tajima, Kenji; Nagai, Hiroshi; Tsuji, Masataka; Yamada, Shigeru
2003-07-01
In this paper, a new application system with high speed photography, i.e. an observational system for the tele-micro-operation, has been proposed with a dynamic focusing system and a high-speed image processing system using the "Depth From Focus (DFF)" criteria. In micro operation, such as for the microsurgery, DNA operation and etc., the small depth of a focus on the microscope makes bad observation. For example, if the focus is on the object, the actuator cannot be seen with the microscope. On the other hand, if the focus is on the actuator, the object cannot be observed. In this sense, the "all-in-focus image," which holds the in-focused texture all over the image, is useful to observe the microenvironments on the microscope. It is also important to obtain the "depth map" which could show the 3D micro virtual environments in real-time to actuate the micro objects, intuitively. To realize the real-time micro operation with DFF criteria, which has to integrate several images to obtain "all-in-focus image" and "depth map," at least, the 240 frames par second based image capture and processing system should be required. At first, this paper briefly reviews the criteria of "depth from focus" to achieve the all-in-focus image and the 3D microenvironments' reconstruction, simultaneously. After discussing the problem in our past system, a new frame-rate system is constructed with the high-speed video camera and FPGA hardware with 240 frames par second. To apply this system in the real microscope, a new criterion "ghost filtering" technique to reconstruct the all-in-focus image is proposed. Finally, the micro observation shows the validity of this system.
Yi, Faliu; Lee, Jieun; Moon, Inkyu
2014-05-01
The reconstruction of multiple depth images with a ray back-propagation algorithm in three-dimensional (3D) computational integral imaging is computationally burdensome. Further, a reconstructed depth image consists of a focus and an off-focus area. Focus areas are 3D points on the surface of an object that are located at the reconstructed depth, while off-focus areas include 3D points in free-space that do not belong to any object surface in 3D space. Generally, without being removed, the presence of an off-focus area would adversely affect the high-level analysis of a 3D object, including its classification, recognition, and tracking. Here, we use a graphics processing unit (GPU) that supports parallel processing with multiple processors to simultaneously reconstruct multiple depth images using a lookup table containing the shifted values along the x and y directions for each elemental image in a given depth range. Moreover, each 3D point on a depth image can be measured by analyzing its statistical variance with its corresponding samples, which are captured by the two-dimensional (2D) elemental images. These statistical variances can be used to classify depth image pixels as either focus or off-focus points. At this stage, the measurement of focus and off-focus points in multiple depth images is also implemented in parallel on a GPU. Our proposed method is conducted based on the assumption that there is no occlusion of the 3D object during the capture stage of the integral imaging process. Experimental results have demonstrated that this method is capable of removing off-focus points in the reconstructed depth image. The results also showed that using a GPU to remove the off-focus points could greatly improve the overall computational speed compared with using a CPU.
Enhanced methodology of focus control and monitoring on scanner tool
NASA Astrophysics Data System (ADS)
Chen, Yen-Jen; Kim, Young Ki; Hao, Xueli; Gomez, Juan-Manuel; Tian, Ye; Kamalizadeh, Ferhad; Hanson, Justin K.
2017-03-01
As the demand of the technology node shrinks from 14nm to 7nm, the reliability of tool monitoring techniques in advanced semiconductor fabs to achieve high yield and quality becomes more critical. Tool health monitoring methods involve periodic sampling of moderately processed test wafers to detect for particles, defects, and tool stability in order to ensure proper tool health. For lithography TWINSCAN scanner tools, the requirements for overlay stability and focus control are very strict. Current scanner tool health monitoring methods include running BaseLiner to ensure proper tool stability on a periodic basis. The focus measurement on YIELDSTAR by real-time or library-based reconstruction of critical dimensions (CD) and side wall angle (SWA) has been demonstrated as an accurate metrology input to the control loop. The high accuracy and repeatability of the YIELDSTAR focus measurement provides a common reference of scanner setup and user process. In order to further improve the metrology and matching performance, Diffraction Based Focus (DBF) metrology enabling accurate, fast, and non-destructive focus acquisition, has been successfully utilized for focus monitoring/control of TWINSCAN NXT immersion scanners. The optimal DBF target was determined to have minimized dose crosstalk, dynamic precision, set-get residual, and lens aberration sensitivity. By exploiting this new measurement target design, 80% improvement in tool-to-tool matching, >16% improvement in run-to-run mean focus stability, and >32% improvement in focus uniformity have been demonstrated compared to the previous BaseLiner methodology. Matching <2.4 nm across multiple NXT immersion scanners has been achieved with the new methodology of set baseline reference. This baseline technique, with either conventional BaseLiner low numerical aperture (NA=1.20) mode or advanced illumination high NA mode (NA=1.35), has also been evaluated to have consistent performance. This enhanced methodology of focus control and monitoring on multiple illumination conditions, opens an avenue to significantly reduce Focus-Exposure Matrix (FEM) wafer exposure for new product/layer best focus (BF) setup.
Inertial particle focusing in serpentine channels on a centrifugal platform
NASA Astrophysics Data System (ADS)
Shamloo, Amir; Mashhadian, Ali
2018-01-01
Inertial particle focusing as a powerful passive method is widely used in diagnostic test devices. It is common to use a curved channel in this approach to achieve particle focusing through balancing of the secondary flow drag force and the inertial lift force. Here, we present a focusing device on a disk based on the interaction of secondary flow drag force, inertial lift force, and centrifugal forces to focus particles. By choosing a channel whose cross section has a low aspect ratio, the mixing effect of the secondary flow becomes negligible. To calculate inertial lift force, which is exerted on the particle from the fluid, the interaction between the fluid and particle is investigated accurately through implementation of 3D Direct Numerical Solution (DNS) method. The particle focusing in three serpentine channels with different corner angles of 75°, 85°, and 90° is investigated for three polystyrene particles with diameters of 8 μm, 9.9 μm, and 13 μm. To show the simulation reliability, the results obtained from the simulations of two examples, namely, particle focusing and centrifugal platform, are verified against experimental counterparts. The effects of angular velocity of disk on the fluid velocity and on the focusing parameters are studied. Fluid velocity in a channel with corner angle of 75° is greater than two other channels. Furthermore, the particle equilibrium positions at the cross section of channel are obtained at the outlet. There are two equilibrium positions located at the centers of the long walls. Finally, the effect of particle density on the focusing length is investigated. A particle with a higher density and larger diameter is focused in a shorter length of the channel compared to its counterpart with a lower density and shorter diameter. The channel with a corner angle of 90° has better focusing efficiency compared to other channels. This design focuses particles without using any pump or sheath flow. Inertial particle focusing on centrifugal platform, which rarely has been studied, can be used for a wide range of diagnostic lab-on-a-disk device.
ERIC Educational Resources Information Center
Spinhoven, Philip; Giesen-Bloo, Josephine; van Dyck, Richard; Kooiman, Kees; Arntz, Arnoud
2007-01-01
This study investigated the quality and development of the therapeutic alliance as a mediator of change in schema-focused therapy (SFT) and transference-focused psychotherapy (TFP) for borderline personality disorder. Seventy-eight patients were randomly allocated to 3 years of biweekly SFT or TFP. Scores of both therapists and patients for the…
Socioeconomic Status and Financial Coping Strategies: The Mediating Role of Perceived Control
ERIC Educational Resources Information Center
Caplan, Leslie J.; Schooler, Carmi
2007-01-01
We examine the relations among socioeconomic status, control beliefs, and two coping styles (problem-focused vs. emotion-focused) in the context of financial stress. Findings indicate that low socioeconomic status (SES) is linked to greater use of emotion-focused financial coping and lesser use of problem-focused financial coping. The effects of…
The Effect of Attentional Focus Cues on Object Control Performance in Elementary Children
ERIC Educational Resources Information Center
Palmer, Kara K.; Matsuyama, Abigail L.; Irwin, J. Megan; Porter, Jared M.; Robinson, Leah E.
2017-01-01
Background and purpose: Attentional focus cues have been shown to impact motor performance of adults and children. Specifically, an external focus of attention results in improved motor learning and performance as compared to adopting an internal focus of attention. The purpose of this study was to determine the effects of an internal and external…
The Use of Online Focus Groups to Design an Online Food Safety Education Intervention
ERIC Educational Resources Information Center
Mayer, Ashley Bramlett; Harrison, Judy A.
2012-01-01
In the development of an online food safety education intervention for college students, online focus groups were used to determine the appropriate format and messages. Focus groups are often used in qualitative research and formative evaluation of public health programs, yet traditional focus groups can be both difficult and expensive to…
ERIC Educational Resources Information Center
Coleman, Sulamunn R. M.; Zawadzki, Matthew J.; Heron, Kristin E.; Vartanian, Lenny R.; Smyth, Joshua M.
2016-01-01
Objectives: This study examined whether self-focused and other-focused resiliency help explain how early family adversity relates to perceived stress, subjective health, and health behaviors in college women. Participants: Female students (N = 795) participated between October 2009 and May 2010. Methods: Participants completed self-report measures…
ERIC Educational Resources Information Center
Rafieyan, Vahid
2016-01-01
To develop target language pragmatic competence, language learners' attention must be directed toward not only linguistic but also pragmatic aspect of the target language expressions (Schmidt, 2001). Thus, some sorts of pragmatic awareness-raising instruction, using either explicit "Focus on Forms" or implicit "Focus on Form"…
Alternative Fuels Data Center: North Carolina's Henderson County Focuses on
Natural Gas North Carolina's Henderson County Focuses on Natural Gas to someone by E-mail Share Alternative Fuels Data Center: North Carolina's Henderson County Focuses on Natural Gas on Facebook Tweet about Alternative Fuels Data Center: North Carolina's Henderson County Focuses on Natural Gas on Twitter
A Proposed Model for the Analysis and Interpretation of Focus Groups in Evaluation Research
ERIC Educational Resources Information Center
Massey, Oliver T.
2011-01-01
Focus groups have an established history in applied research and evaluation. The fundamental methods of the focus group technique have been well discussed, as have their potential advantages. Less guidance tends to be provided regarding the analysis of data resulting from focus groups or how to organize and defend conclusions drawn from the…
Recent High School Graduate Focus Groups. Market Analysis 00-1.
ERIC Educational Resources Information Center
Clagett, Craig A.
This report summarizes findings of focus groups of recent high school graduates conducted during new student orientation at Carroll Community College (CCC) in fall 1999. Students were invited to participate in focus groups at the conclusion of the all-day orientation. Three focus groups were held, two with six participants and one with five…
ERIC Educational Resources Information Center
Ohio State Dept. of Education, Columbus. Div. of Career-Technical and Adult Education.
This book is designed to help academic teachers in middle or secondary education develop an appreciation of career-focused education and begin the process of designing career-focused instruction. (Career-focused instruction is educational programming in which curriculum content and learning experiences clearly connect to the world of work.) For…
A Comparison of Input Enhancement and Explicit Instruction of Mitigators
ERIC Educational Resources Information Center
Fukuya, Yoshinori J.; Clark, Martyn K.
2001-01-01
As the instructional shortcomings of Focus on FormS and Focus on Meaning have surfaced, Focus on Form (i.e., drawing brief attention to linguistic forms while learners engage primarily in meaning) has slowly but steadily gained the attention of researchers and teachers. The research question underlying this study was whether Focus on Form could be…
Writing to Promote and Assess Conceptual Understanding in College Algebra
ERIC Educational Resources Information Center
Gay, A. Susan; Peterson, Ingrid
2014-01-01
Concept-focused quiz questions required College Algebra students to write about their understanding. The questions can be viewed in three broad categories: a focus on sense-making, a focus on describing a mathematical object such as a graph or an equation, and a focus on understanding vocabulary. Student responses from 10 classes were analyzed.…
Incidental Focus on Form in University Spanish Literature Courses
ERIC Educational Resources Information Center
Zyzik, Eve; Polio, Charlene
2008-01-01
Incidental focus on form is one of several ways to direct language learners' attention to formal aspects of language within meaningful communicative contexts. Learners can benefit from focus on form, but the extent to which incidental focus on form, or any other type, is available to learners in advanced foreign language literature classes has not…
Effects of Transferring to STEM-Focused Charter and Magnet Schools on Student Achievement
ERIC Educational Resources Information Center
Judson, Eugene
2014-01-01
There have been strong calls to action in recent years to promote both school choice and the learning of science, technology, engineering, and mathematics (STEM). This has led to the burgeoning development of STEM-focused schools. Nine STEM-focused charter and 2 STEM-focused magnet schools that serve elementary-aged students were examined to…
Processing Focus Structure in L1 and L2 French: L2 Proficiency Effects on ERPs
ERIC Educational Resources Information Center
Reichle, Robert V.; Birdsong, David
2014-01-01
This study examined the event-related potentials (ERPs) elicited by focus processing among first language (L1) speakers and second language (L2) learners of French. Participants read wh-questions containing explicit focus marking, followed by responses instantiating contrastive and informational focus. We hypothesized that L2 proficiency would…
Diffraction crystal for sagittally focusing x-rays
Ice, Gene E.; Sparks, Jr., Cullie J.
1984-01-01
The invention is a new type of diffraction crystal designed for sagittally focusing photons of various energies. The invention is based on the discovery that such focusing is not obtainable with conventional crystals because of distortion resulting from anticlastic curvature. The new crystal comprises a monocrystalline base having a front face contoured for sagittally focusing photons and a back face provided with rigid, upstanding, stiffening ribs restricting anticlastic curvature. When mounted in a suitable bending device, the reflecting face of the crystal can be adjusted to focus photons having any one of a range of energies.
Diffraction crystals for sagittally focusing x-rays
Ice, G.E.; Sparks, C.J. Jr.
1982-06-07
The invention is a new type of diffraction crystal designed for sagittally focusing photons of various energies. The invention is based on the discovery that such focusing is not obtainable with conventional crystals because of distortion resulting from anticlastic curvature. The new crystal comprises a monocrystalline base having a front face contoured for sagittally focusing photons and a back face provided with rigid, upstanding, stiffening ribs restricting anticlastic curvature. When mounted in a suitable bending device, the reflecting face of the crystal can be adjusted to focus photons having any one of a range of energies.
Development of high-order harmonic focusing system based on ellipsoidal mirror
DOE Office of Scientific and Technical Information (OSTI.GOV)
Motoyama, H.; Takei, Y.; Kume, T.
2016-05-15
We have developed a focusing system for extreme ultraviolet light produced by high-order harmonic generation. An ellipsoidal mirror with a precise surface shape was fabricated and installed into the focusing system. A rigid mirror manipulator and a beam profiler were employed to perform precise and stable mirror alignment. As a demonstration of the focusing performance, high-order harmonics in the wavelength range of 13.5–19.5 nm were successfully focused into a 2.4 × 2.3 μm{sup 2} spot.
NASA Technical Reports Server (NTRS)
Lee, J. H.; Mcfarland, D. R.; Harries, W. L.
1978-01-01
A new staged plasma-focus geometry combining two Mather-type plasma-focus guns was constructed, and the current-sheet dynamics were investigated. The production of simultaneous pairs of plasma foci was achieved. The intensities of X-ray and fusion-neutron emission were measured and found to agree with the scaling law for a plasma focus. Advantages of this new geometry include the possibility of using plasma-focus type pinches in multiple arrays at power levels beyond the validity regime of the current scaling law for a single gun.
Mitigating chromatic effects for the transverse focusing of intense charged particle beams
NASA Astrophysics Data System (ADS)
Mitrani, James; Kaganovich, Igor; Davidson, Ronald
2013-09-01
A final focusing scheme designed to minimize chromatic effects is discussed. Solenoids are often used for transverse focusing in accelerator systems that require a charged particle beam with a small focal spot and/or large energy density A sufficiently large spread in axial momentum will reduce the effectiveness of transverse focusing, and result in chromatic effects on the final focal spot. Placing a weaker solenoid upstream of a stronger final focusing solenoid (FFS) mitigates chromatic effects on transverse beam focusing. J.M. Mitrani et al., Nucl. Inst. Meth. Phys. Res. A (2013) http://dx.doi.org/10.1016/j.nima.2013.05.09 This work was supported by DOE contract DE-AC02-09CH11466.
Apparatus, systems, and methods for ultrasound synthetic aperature focusing
Schuster, George J.; Crawford, Susan L.; Doctor, Steven R.; Harris, Robert V.
2005-04-12
One form of the present invention is a technique for interrogating a sample with ultrasound which includes: generating ultrasonic energy data corresponding to a volume of a sample and performing a synthetic aperture focusing technique on the ultrasonic energy data. The synthetic aperture focusing technique includes: defining a number of hyperbolic surfaces which extend through the volume at different depths and a corresponding number of multiple element accumulation vectors, performing a focused element calculation procedure for a group of vectors which are representative of the interior of a designated aperture, performing another focused element calculation procedure for vectors corresponding to the boundary of the aperture, and providing an image corresponding to features of the sample in accordance with the synthetic aperture focusing technique.
Myhre, Kjersti; Marchand, Gunn Hege; Leivseth, Gunnar; Keller, Anne; Bautz-Holter, Erik; Sandvik, Leiv; Lau, Bjørn; Røe, Cecilie
2014-11-15
Multicenter randomized trial with patients listed as sick for 1 to 12 months due to neck or back pain and referred to secondary care. To compare the return-to-work (RTW) rate among patients offered work-focused rehabilitation or multidisciplinary rehabilitation. A growing number of studies have focused on the RTW processes associated with patients with back pain. Many studies have combined a workplace focus with multidisciplinary treatments; however, this focus has not been evaluated in Norway among patients with neck and back pain thus far. A total of 405 patients who were referred to the spine clinics at 2 university hospitals in Norway were randomly assigned into work-focused and control intervention groups. The existing treatments at each hospital were used as the control interventions, which entailed either a comprehensive multidisciplinary intervention or a brief multidisciplinary intervention. The RTW rates and proportions were compared at 12 months. During the first 12 months after inclusion, 142 (70%) participants in the work-focused rehabilitation group and 152 (75%) participants in the control group returned to work. The median time to RTW was 161 days in the work-focused group and 158 days in the control group. A comparison of the work-focused and control interventions revealed a relative RTW probability (hazard ratio) of 0.94 (95% confidence interval = 0.75-1.17) after adjusting for age, sex, and education. The results suggest that a focus on the workplace in specialist care does not substantially alter the RTW rate compared with standard multidisciplinary treatments.
NICMOS Focus and HST Breathing
NASA Astrophysics Data System (ADS)
Suchkov, A.; Hershey, J.
1998-09-01
The program 7608 monitored on a biweekly basis NICMOS camera foci from June 9, 1997, through February 18, 1998. Each of the biweekly observations included 17 measurements of focus position (focus sweeps), individually for each of the three cameras. The measurements for camera 1 and camera 3 foci covered one or two HST orbital periods. Comparison of these measurements with the predictions of the three OTA focus breathing models has shown the following. (1). Focus variations seen in NICMOS focus sweeps correlate well with the OTA focus thermal breathing as predicted by breathing models (“4- temperature”, “full-temperature”, and “attitude” models). Thus they can be attributed mostly to the HST orbital temperature variation. (2). The amount of breathing (breathing amplitude) has been found to be on average larger in the first orbit after a telescope slew to a new target. This is explained as being due to additional thermal perturbations caused by the change in the HST attitude as the telescope repoints to a new target. (3). In the first orbit, the amount of focus change predicted by the 4-temperature model is about the same as that seen in the focus sweeps data (breathing scale factor ~1). However the full-temperature model predicts a two times smaller breathing amplitude (breathing scale factor ~1.7). This suggests that the light shield temperatures are more responsive to the attitude change than temperatures from the other temperature sensors. The results of this study may help to better understand the HST thermal cycles and to improve the models describing the impact of those on both the OTA and NICMOS focus.
Anderson, Edward R; Greene, Shannon M
2011-10-01
Parents who repartner after divorce must decide how to balance the potentially competing demands of their own desire for adult companionship and romance with the needs of their children for parental attention and affection. In this study, the authors assessed individual differences in divorced custodial mothers' orientation toward repartnering, characterizing it as a continuum, ranging from more child focused to more adult focused. Mothers who are more adult focused tend to be older, more educated, more likely to be employed outside the home, and exiting marriages of longer duration. In addition, using longitudinal data from in-home interviews, mothers who are more adult focused reported having lower rapport with their children, spending less time in joint activities with their children, and their children in turn reported lower rapport with their mothers. Levels of adult-focused orientation are relatively stable over time but increase when mothers become involved or interested in new partners. Using longitudinal diary data over a 2-year period, the authors demonstrated that mothers who are more child focused engage in more active management of emergent relationships in repartnered families and that adult-focused and child-focused mothers respond to different concerns. Whereas all mothers become more active in managing emergent relationships when both partner and child are resisting one another, mothers with greater child focus respond more to concerns of the child, and mothers with greater adult focus respond more to the concerns of the partner. Implications for intervention with divorced families are discussed.
Chen, Xiao-Liang; Li, Qian; Cao, Lin; Jiang, Shi-Xi
2014-01-01
The bone metastasis appeared early before the bone imaging for most of the above patients. (99)Tc(m)-MDP ((99)Tc(m) marked methylene diphosphonate) bone imaging could diagnosis the bone metastasis with highly sensitivity, but with lower specificity. The aim of this study is to explore the diagnostic value of (99)Tc(m)-MDP SPECT/CT combined SPECT/MRI Multi modality imaging for the early period atypical bone metastases. 15 to 30 mCi (99)Tc(m)-MDP was intravenously injected to the 34 malignant patients diagnosed as doubtful early bone metastases. SPECT, CT and SPECT/CT images were captured and analyzed consequently. For the patients diagnosed as early period atypical bone metastases by SPECT/CT, combining the SPECT/CT and MRI together as the SPECT/MRI integrated image. The obtained SPECT/MRI image was analyzed and compared with the pathogenic results of patients. The results indicated that 34 early period doubtful metastatic focus, including 34 SPECT positive focus, 17 focus without special changes by using CT method, 11 bone metastases focus by using SPECT/CT method, 23 doubtful bone metastases focus, 8 doubtful bone metastases focus, 14 doubtful bone metastases focus and 2 focus without clear image. Totally, SPECT/CT combined with SPECT/MRI method diagnosed 30 bone metastatic focus and 4 doubtfully metastatic focus. In conclusion, (99)Tc(m)-MDP SPECT/CT combined SPECT/MRI Multi modality imaging shows a higher diagnostic value for the early period bone metastases, which also enhances the diagnostic accuracy rate.
Rodrigues, David; Lopes, Diniz; Kumashiro, Madoka
2017-01-01
When individuals are highly committed to their romantic relationship, they are more likely to engage in pro-relationship maintenance mechanisms. The present research expanded on the notion that commitment redirects self-oriented goals to consider broader relational goals and examined whether commitment interacts with a promotion and prevention focus to activate derogation of attractive alternatives. Three studies used cross-sectional and experimental approaches. Study 1 showed that romantically involved individuals predominantly focused on promotion, but not prevention, reported less initial attraction to an attractive target than single individuals, especially when highly committed to their relationship. Study 2 showed that romantically involved individuals induced in a promotion focus, compared to those in prevention focus, reported less initial attraction, but only when more committed to their relationship. Regardless of regulatory focus manipulation, more committed individuals were also less likely to perceive quality among alternative scenarios and to be attentive to alternative others in general. Finally, Study 3 showed that romantically involved individuals induced in promotion focus and primed with high commitment reported less initial attraction, than those primed with low commitment, or than those induced in prevention focus. Once again, for these latter no differences occurred according to commitment prime. Together, the findings suggest that highly committed promotion focused individuals consider broader relationship goals and activate relationship maintenance behaviors such as derogation of attractive alternatives to promote their relationship.
Design and Fabrication of Double-Focused Ultrasound Transducers to Achieve Tight Focusing.
Jang, Jihun; Chang, Jin Ho
2016-08-06
Beauty treatment for skin requires a high-intensity focused ultrasound (HIFU) transducer to generate coagulative necrosis in a small focal volume (e.g., 1 mm³) placed at a shallow depth (3-4.5 mm from the skin surface). For this, it is desirable to make the F-number as small as possible under the largest possible aperture in order to generate ultrasound energy high enough to induce tissue coagulation in such a small focal volume. However, satisfying both conditions at the same time is demanding. To meet the requirements, this paper, therefore, proposes a double-focusing technique, in which the aperture of an ultrasound transducer is spherically shaped for initial focusing and an acoustic lens is used to finally focus ultrasound on a target depth of treatment; it is possible to achieve the F-number of unity or less while keeping the aperture of a transducer as large as possible. In accordance with the proposed method, we designed and fabricated a 7-MHz double-focused ultrasound transducer. The experimental results demonstrated that the fabricated double-focused transducer had a focal length of 10.2 mm reduced from an initial focal length of 15.2 mm and, thus, the F-number changed from 1.52 to 1.02. Based on the results, we concluded that the proposed double-focusing method is suitable to decrease F-number while maintaining a large aperture size.
Reading in healthy ageing: the influence of information structuring in sentences.
Price, Jessica M; Sanford, Anthony J
2012-06-01
In three experiments, we investigated the cognitive effects of linguistic prominence to establish whether focus plays a similar or different role in modulating language processing in healthy ageing. Information structuring through the use of cleft sentences is known to increase the processing efficiency of anaphoric references to elements contained with a marked focus structure. It also protects these elements from becoming suppressed in the wake of subsequent information, suggesting selective mechanisms of enhancement and suppression. In Experiment 1 (using self-paced reading), we found that focus enhanced (faster) integration for anaphors referring to words contained within the scope of focus; but suppressed (slower) integration for anaphors to words contained outside of the scope of focus; and in some cases, the effects were larger in older adults. In Experiment 2 (using change detection), we showed that older adults relied more on the linguistic structure to enhance change detection when the changed word was in focus. In Experiment 3 (using delayed probe recognition and eye-tracking), we found that older adults recognized probes more accurately when they were made to elements within the scope of focus than when they were outside the scope of focus. These results indicate that older adults' ability to selectively attend or suppress concepts in a marked focus structure is preserved. PsycINFO Database Record (c) 2012 APA, all rights reserved
Mikels, Joseph A; Löckenhoff, Corinna E; Maglio, Sam J; Goldstein, Mary K; Garber, Alan; Carstensen, Laura L
2010-03-01
Research on aging has indicated that whereas deliberative cognitive processes decline with age, emotional processes are relatively spared. To examine the implications of these divergent trajectories in the context of health care choices, we investigated whether instructional manipulations emphasizing a focus on feelings or details would have differential effects on decision quality among younger and older adults. We presented 60 younger and 60 older adults with health care choices that required them to hold in mind and consider multiple pieces of information. Instructional manipulations in the emotion-focus condition asked participants to focus on their emotional reactions to the options, report their feelings about the options, and then make a choice. In the information-focus condition, participants were instructed to focus on the specific attributes, report the details about the options, and then make a choice. In a control condition, no directives were given. Manipulation checks indicated that the instructions were successful in eliciting different modes of processing. Decision quality data indicate that younger adults performed better in the information-focus than in the control condition whereas older adults performed better in the emotion-focus and control conditions than in the information-focus condition. Findings support and extend extant theorizing on aging and decision making as well as suggest that interventions to improve decision-making quality should take the age of the decision maker into account.
ERIC Educational Resources Information Center
Kucan, Linda; Palincsar, Annemarie Sullivan
2018-01-01
This investigation focuses on a tool used in a reading methods course to introduce reading specialist candidates to text analysis as a critical component of planning for text-based discussions. Unlike planning that focuses mainly on important text content or information, a text analysis approach focuses both on content and how that content is…
Focus Groups to Explore the Perceptions of Older Adults on a Pedometer-Based Intervention
ERIC Educational Resources Information Center
Jones, David B.; Richeson, Nancy E.; Croteau, Karen A.; Farmer, Bonnie Cashin
2009-01-01
Focus group methodology was used to explore in depth the perceptions of older adults who had participated in a 12-week pedometer-based intervention. Nineteen women and 8 men, ages 55-86 years, volunteered to take part in the focus groups following participation in the intervention. Four focus groups of six to eight participants were scheduled at…
ERIC Educational Resources Information Center
Agar, Charles; Humphries, Charlotte A.; Naquin, Millie; Hebert, Edward; Wood, Ralph
2016-01-01
Recently, researchers have concluded that motor skill performance is enhanced when learners adopt an external attentional focus, compared to adopting an internal focus. We extended the line of inquiry to children and examined if skill learning in children was differentially affected by providing instructions and feedback that direct attentional…
Sexual Encounters: Gay Male College Students' Use of the Internet and Social Media
ERIC Educational Resources Information Center
Reddick, Rinardo Lamon
2012-01-01
There have been many studies that focus on understanding various aspects of human sexuality and how it relates to college students. However, the current research focuses on heterosexual students, leaving a void in the research that focuses on gay male college students. Even more crucially, there is a void in research that focuses on the sexual…
Engaging Focus Group Methodology: The 4-H Middle School-Aged Youth Learning and Leading Study
ERIC Educational Resources Information Center
Scott, Siri; Grant, Samantha; Nippolt, Pamela Larson
2015-01-01
With young people, discussing complex issues such as learning and leading in a focus group can be a challenge. To help prime youth for the discussion, we created a focus group approach that featured a fun, interactive activity. This article includes a description of the focus group activity, lessons learned, and suggestions for additional…
The Pitfalls and Promise of Focus Groups as a Data Collection Method
ERIC Educational Resources Information Center
Cyr, Jennifer
2016-01-01
Despite their long trajectory in the social sciences, few systematic works analyze how often and for what purposes focus groups appear in published works. This study fills this gap by undertaking a meta-analysis of focus group use over the last 10 years. It makes several contributions to our understanding of when and why focus groups are used in…
Applying Form-Focused Approaches to L2 Vocabulary Instruction through Video Podcasts
ERIC Educational Resources Information Center
Marefat, Fahimeh; Hassanzadeh, Mohammad
2016-01-01
Since its inception, form-focused instruction (FFI) has been associated with grammar, with only a handful of studies examining its potential for vocabulary development (e.g., Laufer, 2006). Meanwhile, there has been an unresolved dispute between the two approaches of Focus on Form (FonF) and Focus on Forms (FonFs) in terms of their degree of…
ERIC Educational Resources Information Center
Abbasian, Gholam-Reza; Pooshaneh, Leila
2015-01-01
Many empirical investigations have demonstrated that explicit Focus on Form (FOF) methods are more effective than implicit Focus on Meaning (FOM) methods (Norris & Ortega, 2000), because in FOF instruction learners' attention is drawn to linguistic form while FOM instruction requires learners' attention to communicate (Ellis, 2001). However,…
ERIC Educational Resources Information Center
Pascall, Melvin A.; Lee, Ken; Fraser, Angela; Halim, Linna
2009-01-01
A focus group with an educational component was used to help initiate a new research hypothesis. Early-stage development of a new tamper-evident invention was improved with input from a consumer focus group. The focus group comprised consumers who were shown several tamper-evident devices, including a new color-changing cap under active…
ERIC Educational Resources Information Center
Shu, Tse-Mei; Lam, Shui-fong
2011-01-01
The present study extended regulatory focus theory (Idson & Higgins, 2000) to an educational setting and attempted to identify individuals with high motivation after both success and failure feedback. College students in Hong Kong (N = 180) participated in an experiment with a 2 promotion focus (high vs. low) x 2 prevention focus (high vs.…
ERIC Educational Resources Information Center
Loewen, Shawn
2011-01-01
Focus on form, i.e. brief attention to language items within a larger meaning-focused context (Long 1991; Ellis 2001), occurs in a variety of L2 instructional contexts. Meta-analyses of the effectiveness of focus on form have found overall positive effects; however, these meta-analyses have commented on the small number of studies available for…
Focused search of semantic cases: the effects of question form and case status.
Singer, M; Jakobson, L S
1989-05-01
The present study was designed to identify and examine some of the variables that influence the focused search of semantic cases in question answering. Singer, Parbery, and Jakobson (1988) have previously reported that people can focus on the case interrogated by a question and can largely disregard irrelevant cases. In the present study, people learned facts, such as the pilot painted the garage with the roller, the spraygun, and the brush. One day later, they answered questions that focused on a particular case. For example, the question did the pilot paint with a spraygun? focuses on the instrument case. Experiment 1 revealed that people can focus on a particular case in response both to complete questions and to comparable word probes, such as "pilot spraygun." Therefore, the given-new structure of questions is not essential to focused search. Experiment 2 revealed that people have a difficult time ignoring the agent case, even when it is irrelevant to the question. This corroborates proposals that agent and action information are closely interrelated in the representation of a fact. These results help to delineate the phenomenon of the focused search of semantic cases.
Experiential self-focus writing as a facilitator of processing an interpersonal hurt.
Liao, Kelly Yu-Hsin; Wei, Meifen; Russell, Daniel W; Abraham, W Todd
2012-10-01
This study examined the effects of experiential self-focus writing on changes in psychological outcomes (i.e., unforgiveness and negative affect) after an interpersonal hurt and the buffering effects of experiential self-focus writing on the association between anger rumination and these psychological outcomes. A sample of 182 college students who had experienced interpersonal hurt were randomly assigned to either the experiential self-focus writing condition, in which participants wrote about their feelings and experiences related to the hurt, or to a control writing condition in which they wrote about a recent neutral event. Latent growth curve analyses indicated that changes in unforgiveness over time did not differ between the experiential self-focus writing and the control writing conditions. However, relative to the control writing condition, negative affect decreased faster during writing and increased more slowly at follow-ups in the experiential self-focus writing condition. The results supported the hypothesis that negative affect resulting from an interpersonal hurt would significantly decrease over time among participants in the experiential self-focus writing group compared with the control group. Implications of experiential self-focus writing for interpersonal hurt and directions for future studies are discussed. © 2012 Wiley Periodicals, Inc.
Engineering of multi-segmented light tunnel and flattop focus with designed axial lengths and gaps
NASA Astrophysics Data System (ADS)
Yu, Yanzhong; Huang, Han; Zhou, Mianmian; Zhan, Qiwen
2018-01-01
Based on the radiation pattern from a sectional-uniform line source antenna, a three-dimensional (3D) focus engineering technique for the creation of multi-segmented light tunnel and flattop focus with designed axial lengths and gaps is proposed. Under a 4Pi focusing system, the fields radiated from sectional-uniform magnetic and electromagnetic current line source antennas are employed to generate multi-segmented optical tube and flattop focus, respectively. Numerical results demonstrate that the produced light tube and flattop focus remain homogeneous along the optical axis; and their lengths of the nth segment and the nth gap between consecutive segments can be easily adjusted and only depend on the sizes of the nth section and the nth blanking between adjacent sectional antennas. The optical tube is a pure azimuthally polarized field but for the flattop focus the longitudinal polarization is dominant on the optical axis. To obtain the required pupil plane illumination for constructing the above focal field with prescribed characteristics, the inverse problem of the antenna radiation field is solved. These peculiar focusing fields might find potential applications in multi-particle acceleration, multi-particle trapping and manipulation.
Stoverink, Adam C; Umphress, Elizabeth E; Gardner, Richard G; Miner, Kathi N
2014-11-01
The organizational justice literature has examined the effects of supervisor-focused interpersonal justice climate, or a team's shared perception of the dignity and respect it receives from its supervisor, on a number of important outcomes directed at organizational authorities. Considerably less is known about the potential influence of these shared perceptions on coworker-directed outcomes. In 2 experiments, we predict that a low (unfair) supervisor-focused interpersonal justice climate generates greater team cohesiveness than a high (fair) supervisor-focused interpersonal justice climate. We further examine the process through which this effect occurs. Drawing from cognitive dissonance theory, we predict that low (vs. high) supervisor-focused interpersonal justice climate generates greater team dissonance, or shared psychological discomfort, for team members and that this dissonance serves as an underlying mechanism through which supervisor-focused interpersonal justice climate influences a team's cohesiveness. Our results demonstrate support for these predictions in that low supervisor-focused interpersonal justice climate led to higher levels of both team dissonance and team cohesiveness than did high supervisor-focused interpersonal justice climate, and team dissonance mediated this relationship. Implications and areas for future research are discussed. (PsycINFO Database Record (c) 2014 APA, all rights reserved).
Durlik, Caroline; Cardini, Flavia; Tsakiris, Manos
2014-04-01
We become aware of our bodies interoceptively, by processing signals arising from within the body, and exteroceptively, by processing signals arising on or outside the body. Recent research highlights the importance of the interaction of exteroceptive and interoceptive signals in modulating bodily self-consciousness. The current study investigated the effect of social self-focus, manipulated via a video camera that was facing the participants and that was either switched on or off, on interoceptive sensitivity (using a heartbeat perception task) and on tactile perception (using the Somatic Signal Detection Task (SSDT)). The results indicated a significant effect of self-focus on SSDT performance, but not on interoception. SSDT performance was not moderated by interoceptive sensitivity, although interoceptive sensitivity scores were positively correlated with false alarms, independently of self-focus. Together with previous research, our results suggest that self-focus may exert different effects on body perception depending on its mode (private versus social). While interoception has been previously shown to be enhanced by private self-focus, the current study failed to find an effect of social self-focus on interoceptive sensitivity, instead demonstrating that social self-focus improves exteroceptive somatosensory processing. Copyright © 2014 Elsevier Inc. All rights reserved.
Multispectral variable magnification glancing incidence x ray telescope
NASA Technical Reports Server (NTRS)
Hoover, Richard B. (Inventor)
1992-01-01
A multispectral, variable magnification, glancing incidence, x-ray telescope capable of broadband, high resolution imaging of solar and stellar x-ray and extreme ultraviolet radiation sources is discussed. The telescope includes a primary optical system which focuses the incoming radiation to a primary focus. Two or more rotatable mirror carriers, each providing a different magnification, are positioned behind the primary focus at an inclination to the optical axis. Each carrier has a series of ellipsoidal mirrors, and each mirror has a concave surface covered with a multilayer (layered synthetic microstructure) coating to reflect a different desired wavelength. The mirrors of both carriers are segments of ellipsoids having a common first focus coincident with the primary focus. A detector such as an x-ray sensitive photographic film is positioned at the second respective focus of each mirror so that each mirror may reflect the image at the first focus to the detector at the second focus. The carriers are selectively rotated to position a selected mirror for receiving radiation from the primary optical system, and at least the first carrier may be withdrawn from the path of the radiation to permit a selected mirror on the second carrier to receive the radiation.
Vector fields in a tight laser focus: comparison of models.
Peatross, Justin; Berrondo, Manuel; Smith, Dallas; Ware, Michael
2017-06-26
We assess several widely used vector models of a Gaussian laser beam in the context of more accurate vector diffraction integration. For the analysis, we present a streamlined derivation of the vector fields of a uniformly polarized beam reflected from an ideal parabolic mirror, both inside and outside of the resulting focus. This exact solution to Maxwell's equations, first developed in 1920 by V. S. Ignatovsky, is highly relevant to high-intensity laser experiments since the boundary conditions at a focusing optic dictate the form of the focus in a manner analogous to a physical experiment. In contrast, many models simply assume a field profile near the focus and develop the surrounding vector fields consistent with Maxwell's equations. In comparing the Ignatovsky result with popular closed-form analytic vector models of a Gaussian beam, we find that the relatively simple model developed by Erikson and Singh in 1994 provides good agreement in the paraxial limit. Models involving a Lax expansion introduce a divergences outside of the focus while providing little if any improvement in the focal region. Extremely tight focusing produces a somewhat complicated structure in the focus, and requires the Ignatovsky model for accurate representation.
Pula, Kacy; Parks, Craig D; Ross, Carolyn F
2014-07-01
The authors tested the robustness of the Food Choice Questionnaire (FCQ) with a U.S. sample and examined the relationship between individual differences in regulatory focus and everyday food choice motives. Although a popular measure in cross-culture research, the FCQ has seen limited use with U.S. samples, and its psychometric properties have not been tested in this population. American participants (n = 408) completed the Regulatory Focus Questionnaire and a measure of food choice motives. The data did not support the nine-factor FCQ structure. An ad hoc revised measure of food choice motives showed complete measurement invariance (loadings, intercepts, and residuals) across regulatory focus. Regarding everyday food choices, participants with a prevention focus placed greater importance on mood, convenience, and familiarity than participants with a promotion focus. There were no significant differences regarding the importance of health, environmental protection, impression management, natural content, price, and sensory appeal. Several food choice motives were positively correlated. Compared with the promotion-focused participants, the prevention-focused participants more strongly associated the importance of sensory appeal with the importance of natural content and the importance of price. Copyright © 2014 Elsevier Ltd. All rights reserved.
Automatic optimization high-speed high-resolution OCT retinal imaging at 1μm
NASA Astrophysics Data System (ADS)
Cua, Michelle; Liu, Xiyun; Miao, Dongkai; Lee, Sujin; Lee, Sieun; Bonora, Stefano; Zawadzki, Robert J.; Mackenzie, Paul J.; Jian, Yifan; Sarunic, Marinko V.
2015-03-01
High-resolution OCT retinal imaging is important in providing visualization of various retinal structures to aid researchers in better understanding the pathogenesis of vision-robbing diseases. However, conventional optical coherence tomography (OCT) systems have a trade-off between lateral resolution and depth-of-focus. In this report, we present the development of a focus-stacking optical coherence tomography (OCT) system with automatic optimization for high-resolution, extended-focal-range clinical retinal imaging. A variable-focus liquid lens was added to correct for de-focus in real-time. A GPU-accelerated segmentation and optimization was used to provide real-time layer-specific enface visualization as well as depth-specific focus adjustment. After optimization, multiple volumes focused at different depths were acquired, registered, and stitched together to yield a single, high-resolution focus-stacked dataset. Using this system, we show high-resolution images of the ONH, from which we extracted clinically-relevant parameters such as the nerve fiber layer thickness and lamina cribrosa microarchitecture.
Perpendicular Diffusion Coefficient of Comic Rays: The Presence of Weak Adiabatic Focusing
NASA Astrophysics Data System (ADS)
Wang, J. F.; Qin, G.; Ma, Q. M.; Song, T.; Yuan, S. B.
2017-08-01
The influence of adiabatic focusing on particle diffusion is an important topic in astrophysics and plasma physics. In the past, several authors have explored the influence of along-field adiabatic focusing on the parallel diffusion of charged energetic particles. In this paper, using the unified nonlinear transport theory developed by Shalchi and the method of He and Schlickeiser, we derive a new nonlinear perpendicular diffusion coefficient for a non-uniform background magnetic field. This formula demonstrates that the particle perpendicular diffusion coefficient is modified by along-field adiabatic focusing. For isotropic pitch-angle scattering and the weak adiabatic focusing limit, the derived perpendicular diffusion coefficient is independent of the sign of adiabatic focusing characteristic length. For the two-component model, we simplify the perpendicular diffusion coefficient up to the second order of the power series of the adiabatic focusing characteristic quantity. We find that the first-order modifying factor is equal to zero and that the sign of the second order is determined by the energy of the particles.
NASA Astrophysics Data System (ADS)
Shinoda, Masahisa; Nakatani, Hidehiko; Nakai, Kenya; Ohmaki, Masayuki
2015-09-01
We theoretically calculate behaviors of focusing error signals generated by an astigmatic method in a land-groove-type optical disk. The focusing error signal from the land does not coincide with that from the groove. This behavior is enhanced when a focused spot of an optical pickup moves beyond the radius of the optical disk. A gain difference between the slope sensitivities of focusing error signals from the land and the groove is an important factor with respect to stable focusing servo control. In our calculation, the format of digital versatile disc-random access memory (DVD-RAM) is adopted as the land-groove-type optical disk model, and the dependences of the gain difference on various factors are investigated. The gain difference strongly depends on the optical intensity distribution of the laser beam in the optical pickup. The calculation method and results in this paper will be reflected in newly developed land-groove-type optical disks.
Focusing a fountain of neutral cesium atoms with an electrostatic lens triplet
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kalnins, Juris G.; Amini, Jason M.; Gould, Harvey
2005-10-15
An electrostatic lens with three focusing elements in an alternating-gradient configuration is used to focus a fountain of cesium atoms in their ground (strong-field-seeking) state. The lens electrodes are shaped to produce only sextupole plus dipole equipotentials which avoids adding the unnecessary nonlinear forces present in cylindrical lenses. Defocusing between lenses is greatly reduced by having all of the main electric fields point in the same direction and be of nearly equal magnitude. The addition of the third lens gave us better control of the focusing strength in the two transverse planes and allowed focusing of the beam to halfmore » the image size in both planes. The beam envelope was calculated for lens voltages selected to produced specific focusing properties. The calculations, starting from first principles, were compared with measured beam sizes and found to be in good agreement. Application to fountain experiments, atomic clocks, and focusing polar molecules in strong-field-seeking states is discussed.« less
Scholl, Annika; Sassenberg, Kai; Scheepers, Daan; Ellemers, Naomi; de Wit, Frank
2017-03-01
Social power implies responsibility. Yet, power-holders often follow only their own interests and overlook this responsibility. The present research illuminates how a previously adopted cognitive focus guides perceived responsibility when a person receives high (vs. low) power. In three experiments, adopting a cognitive focus on another person (vs. on the self or taking over another person's perspective) promoted perceived responsibility among individuals receiving high (but not low) power in a subsequent context. This effect was specific for perceived responsibility - a cognitive focus on another person did not change the perceived opportunity to pursue goals or the perceived relationship to an interaction partner (e.g., interpersonal closeness). While prior research examined how social values (i.e., chronically caring about others) guide responsibility among those holding power, the current findings highlight that mere cognitive processes (i.e., situationally focusing attention on others) alter perceived responsibility among those just about to receive power. © 2016 The British Psychological Society.
Positive focal shift of gallium nitride high contrast grating focusing reflectors
NASA Astrophysics Data System (ADS)
He, Shumin; Wang, Zhenhai; Liu, Qifa
2016-09-01
We design a type of metasurfaces capable of serving as a visible-light focusing reflector based on gallium nitride (GaN) high contrast gratings (HCGs). The wavefront of the reflected light is precisely manipulated by spatial variation of the grating periods along the subwavelength ridge array to achieve light focusing. Different from conventional negative focal shift effect, a positive focal shift is observed in such focusing reflectors. Detailed investigations of the influence of device size on the focusing performance, especially the focal length, are preformed via a finite element method . The results show that all performance parameters are greatly affected by the reflector size. A more concentrated focal point, or a better focusing capability, can be achieved by larger size. With increasing reflector size, the achieved focal length decreases and gradually approaches to the design, thus the corresponding positive focal shift decreases. Our results are helpful for understanding the visible-light control of the planar HCG-based focusing reflectors.
Gebauer, Petr; Malá, Zdena; Bocek, Petr
2010-03-01
This contribution introduces a new separation principle in CE which offers focusing of weak nonamphoteric ionogenic species and their inherent transport to the detector. The prerequisite condition for application of this principle is the existence of an inverse electromigration dispersion profile, i.e. a profile where pH is decreasing toward the anode or cathode for focusing of anionic or cationic weak analytes, respectively. The theory presented defines the principal conditions under which an analyte is focused on a profile of this type. Since electromigration dispersion profiles are migrating ones, the new principle offers inherent transport of focused analytes into the detection cell. The focusing principle described utilizes a mechanism different from both CZE (where separation is based on the difference in mobilities) and IEF (where separation is based on difference in pI), and hence, offers another separation dimension in CE. The new principle and its theory presented here are supplemented by convincing experiments as their proof.
Electron Beam Focusing in the Linear Accelerator (linac)
NASA Astrophysics Data System (ADS)
Jauregui, Luis
2015-10-01
To produce consistent data with an electron accelerator, it is critical to have a well-focused beam. To keep the beam focused, quadrupoles (quads) are employed. Quads are magnets, which focus the beam in one direction (x or y) and defocus in the other. When two or more quads are used in series, a net focusing effect is achieved in both vertical and horizontal directions. At start up there is a 5% calibration error in the linac at Thomas Jefferson National Accelerator Facility. This means that the momentum of particles passing through the quads isn't always what is expected, which affects the focusing of the beam. The objective is to find exactly how sensitive the focusing in the linac is to this 5% error. A linac was simulated, which contained 290 RF Cavities with random electric fields (to simulate the 5% calibration error), and a total momentum kick of 1090 MeV. National Science Foundation, Department of Energy, Jefferson Lab, Old Dominion University.
Silvia, Paul J
2012-07-01
Using motivational intensity theory as a framework, three experiments examined how implicit self-focus (manipulated with masked first-name priming) and explicit self-focus (manipulated with a large mirror) influence effort-related cardiovascular activity, particularly systolic blood pressure reactivity. Theories of self-focused attention suggest that both implicit and explicit self-focus bring about self-evaluation and thus make meeting a goal more important. For a "do your best" task of unfixed difficulty, implicit and explicit self-focus both increased effort (Experiment 1) compared to a control condition. For a task that varied in difficulty, implicit and explicit self-focus promoted more effort as the task became increasingly hard (Experiments 2 and 3). Taken together, the findings suggest that implicit and explicit self-processes share a similar motivational architecture. The discussion explores the value of integrating motivational intensity theory with self-awareness theory and considers the emerging interest in implicit aspects of effort regulation. Copyright © 2012 Elsevier B.V. All rights reserved.
Úbeda-Gómez, J; León-Palacios, M G; Escudero-Pérez, S; Barros-Albarrán, M D; López-Jiménez, A M; Perona-Garcelán, S
2015-01-01
The purpose of this study was to investigate the relationships among self-focused attention, mindfulness and distress caused by the voices in psychiatric patients. Fifty-one individuals with a psychiatric diagnosis participated in this study. The Psychotic Symptom Rating Scale (PSYRATS) emotional factor was applied to measure the distress caused by the voices, the Self-Absorption Scale (SAS) was given for measuring the levels of self-focused attention, and the Mindful Attention Awareness Scale (MAAS) was used to measure mindfulness. The results showed that distress caused by the voices correlated positively with self-focused attention (private and public) and negatively with mindfulness. A negative correlation was also found between mindfulness and self-focused attention (private and public). Finally, multiple linear regression analysis showed that public self-focus was the only factor predicting distress caused by the voices. Intervention directed at diminishing public self-focused attention and increasing mindfulness could improve distress caused by the voices.
Effects of prenatal exposure to opioids on focused attention in toddlers during free play.
Schneider, J W; Hans, S L
1996-08-01
The goals of this study were: (1) to determine if 24-month-old children exposed to opioids show decreased focused attention during free play compared with children of the same age who were not prenatally exposed; (2) to identify medical and social risk factors other than drug exposure that are related to focused attention; and (3) to determine if mothers' teaching ability had an effect on attention. Focused attention was rated during a 3-minute free play session for 30 toddlers who were methadone-exposed and for 44 comparison toddlers. The mother teaching the child to use a toy was also rated separately from the free play session. There was no difference in focused attention of 24 month olds during free play based only on prenatal exposure. Despite group differences in medical and social risk factors, only maternal IQ was significantly related to focused attention. Maternal instruction was strongly related to focused attention and mediated the effects of maternal IQ on attention.
Does distraction facilitate problem-focused coping with job stress? A 1 year longitudinal study.
Shimazu, Akihito; Schaufeli, Wilmar B
2007-10-01
This study examined the sole and combined effects of problem-focused coping and distraction on employee well-being (i.e., stress responses and job performance) using two-wave panel survey data with a 1-year time lag. Participants were 488 male employees, who worked for a construction machinery company in western Japan. Hierarchical multiple regression analyses were conducted to examine whether distraction moderates the relationship of problem-focused coping with well-being. More use of problem-focused coping was negatively related to subsequent stress responses among those high in distraction. The combination of high problem-focused coping and high distraction was positively related to subsequent job performance, although it was limited only to the high job stress situation. Results suggest that the combination of high problem-focused coping and high distraction may lead to lower stress responses and better performance (but only in high job stress situations for performance) than the combination of high problem-focused coping and low distraction, at least for male blue-collar workers.
Dynamic-Receive Focusing with High-Frequency Annular Arrays
NASA Astrophysics Data System (ADS)
Ketterling, J. A.; Mamou, J.; Silverman, R. H.
High-frequency ultrasound is commonly employed for ophthalmic and small-animal imaging because of the fine-resolution images it affords. Annular arrays allow improved depth of field and lateral resolution versus commonly used single-element, focused transducers. The best image quality from an annular array is achieved by using synthetic transmit-to-receive focusing while utilizing data from all transmit-to-receive element combinations. However, annular arrays must be laterally scanned to form an image and this requires one pass for each of the array elements when implementing full synthetic transmit-to-receive focusing. A dynamic-receive focusing approach permits a single pass, although at a sacrifice of depth of field and lateral resolution. A five-element, 20-MHz annular array is examined to determine the acoustic beam properties for synthetic and dynamic-receive focusing. A spatial impulse response model is used to simulate the acoustic beam properties for each focusing case and then data acquired from a human eye-bank eye are processed to demonstrate the effect of each approach on image quality.
Effects of vision on head-putter coordination in golf.
Gonzalez, David Antonio; Kegel, Stefan; Ishikura, Tadao; Lee, Tim
2012-07-01
Low-skill golfers coordinate the movements of their head and putter with an allocentric, isodirectional coupling, which is opposite to the allocentric, antidirectional coordination pattern used by experts (Lee, Ishikura, Kegel, Gonzalez, & Passmore, 2008). The present study investigated the effects of four vision conditions (full vision, no vision, target focus, and ball focus) on head-putter coupling in low-skill golfers. Performance in the absence of vision resulted in a level of high isodirectional coupling that was similar to the full vision condition. However, when instructed to focus on the target during the putt, or focus on the ball through a restricted viewing angle, low-skill golfers significantly decoupled the head--putter coordination pattern. However, outcome measures demonstrated that target focus resulted in poorer performance compared with the other visual conditions, thereby providing overall support for use of a ball focus strategy to enhance coordination and outcome performance. Focus of attention and reduced visual tracking were hypothesized as potential reasons for the decoupling.
Focus-on-form instructional methods promote deaf college students' improvement in English grammar.
Berent, Gerald P; Kelly, Ronald R; Aldersley, Stephen; Schmitz, Kathryn L; Khalsa, Baldev Kaur; Panara, John; Keenan, Susan
2007-01-01
Focus-on-form English teaching methods are designed to facilitate second-language learners' noticing of target language input, where "noticing" is an acquisitional prerequisite for the comprehension, processing, and eventual integration of new grammatical knowledge. While primarily designed for teaching hearing second-language learners, many focus-on-form methods lend themselves to visual presentation. This article reports the results of classroom research on the visually based implementation of focus-on-form methods with deaf college students learning English. Two of 3 groups of deaf students received focus-on-form instruction during a 10-week remedial grammar course; a third control group received grammatical instruction that did not involve focus-on-form methods. The 2 experimental groups exhibited significantly greater improvement in English grammatical knowledge relative to the control group. These results validate the efficacy of visually based focus-on-form English instruction for deaf students of English and set the stage for the continual search for innovative and effective English teaching methodologies.
Identifying the role of initial wave parameters on tsunami focusing
NASA Astrophysics Data System (ADS)
Aydın, Baran
2018-04-01
Unexpected local tsunami amplification, which is referred to as tsunami focusing, is attributed to two different mechanisms: bathymetric features of the ocean bottom such as underwater ridges and dipolar shape of the initial wave itself. In this study, we characterize the latter; that is, we explore how amplitude and location of the focusing point vary with certain geometric parameters of the initial wave such as its steepness and crest length. Our results reveal two important features of tsunami focusing: for mild waves maximum wave amplitude increases significantly with transverse length of wave crest, while location of the focusing point is almost invariant. For steep waves, on the other hand, increasing crest length dislocates focusing point significantly, while it causes a rather small increase in wave maximum.
Temporal focusing microscopy combined with three-dimensional structured illumination
NASA Astrophysics Data System (ADS)
Isobe, Keisuke; Toda, Keisuke; Song, Qiyuan; Kannari, Fumihiko; Kawano, Hiroyuki; Miyawaki, Atsushi; Midorikawa, Katsumi
2017-05-01
Temporal focusing microscopy provides the optical sectioning capability in wide-field two-photon fluorescence imaging. Here, we demonstrate temporal focusing microscopy combined with three-dimensional structured illumination, which enables us to enhance the three-dimensional spatial resolution and reject the background fluorescence. Experimentally, the periodic pattern of the illumination was produced not only in the lateral direction but also in the axial direction by the interference between three temporal focusing pulses, which were easily generated using a digital micromirror device. The lateral resolution and optical sectioning capability were successfully enhanced by factors of 1.6 and 3.6, respectively, compared with those of temporal focusing microscopy. In the two-photon fluorescence imaging of a tissue-like phantom, the out-of-focus background fluorescence and the scattered background fluorescence could also be rejected.
Criteria for the selection of focusing ultrasonic probes
NASA Technical Reports Server (NTRS)
Schlengermann, U.
1978-01-01
The principles of operation employed in the focusing of a sound field are considered, taking into account the use of solid and liquid coupling media. The focusing limits for a given transducer are investigated. As a diffraction phenomenon, focusing is a function of the system dimensions, the frequency, and the sound velocity. The frequency and the material used for the lenses are in most cases determined in accordance with considerations regarding sound propagation. Changes in the focus are therefore effected mainly by the selection of transducer and lens dimensions. The functions of the focusing factor for a normal immersion probe and a direct contact angle probe are represented in graphs. The deviation of the appropriate parametric values for an ultrasonic probe is illustrated with the aid of examples.
Regulatory focus moderates the social performance of individuals who conceal a stigmatized identity.
Newheiser, Anna-Kaisa; Barreto, Manuela; Ellemers, Naomi; Derks, Belle; Scheepers, Daan
2015-12-01
People often choose to hide a stigmatized identity to avoid bias. However, hiding stigma can disrupt social interactions. We considered whether regulatory focus qualifies the social effects of hiding stigma by examining interactions in which stigmatized participants concealed a devalued identity from non-stigmatized partners. In the Prevention Focus condition, stigmatized participants were instructed to prevent a negative impression by concealing the identity; in the Promotion Focus condition, they were instructed to promote a positive impression by concealing the identity; in the Control condition, they were simply asked to conceal the identity. Both non-stigmatized partners and independent raters rated the interactions more positively in the Promotion Focus condition. Thus, promotion focus is interpersonally beneficial for individuals who conceal a devalued identity. © 2015 The British Psychological Society.
Paraxial ray solution for liquid-filled variable focus lenses
NASA Astrophysics Data System (ADS)
Wang, Lihui; Oku, Hiromasa; Ishikawa, Masatoshi
2017-12-01
We propose a general solution for determining the cardinal points and effective focal length of a liquid-filled variable focus lens to aid in understanding the dynamic behavior of the lens when the focal length is changed. A prototype of a variable focus lens was fabricated and used to validate the solution. A simplified solution was also presented that can be used to quickly and conveniently calculate the performance of the lens. We expect that the proposed solutions will improve the design of optical systems that contain variable focus lenses, such as machine vision systems with zoom and focus functions.
Focus characterization at an X-ray free-electron laser by coherent scattering and speckle analysis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sikorski, Marcin; Song, Sanghoon; Schropp, Andreas
2015-04-14
X-ray focus optimization and characterization based on coherent scattering and quantitative speckle size measurements was demonstrated at the Linac Coherent Light Source. Its performance as a single-pulse free-electron laser beam diagnostic was tested for two typical focusing configurations. The results derived from the speckle size/shape analysis show the effectiveness of this technique in finding the focus' location, size and shape. In addition, its single-pulse compatibility enables users to capture pulse-to-pulse fluctuations in focus properties compared with other techniques that require scanning and averaging.
Focusing hard x rays beyond the critical angle of total reflection by adiabatically focusing lenses
DOE Office of Scientific and Technical Information (OSTI.GOV)
Patommel, Jens; Klare, Susanne; Hoppe, Robert
In response to the conjecture that the numerical aperture of x-ray optics is fundamentally limited by the critical angle of total reflection, the concept of adiabatically focusing refractive lenses was proposed to overcome this limit. Here, we present an experimental realization of these optics made of silicon and demonstrate that they indeed focus 20 keV x rays to a 18.4 nm focus with a numerical aperture of 1.73(9) × 10 –3 that clearly exceeds the critical angle of total reflection of 1.55 mrad.
Focusing hard x rays beyond the critical angle of total reflection by adiabatically focusing lenses
Patommel, Jens; Klare, Susanne; Hoppe, Robert; ...
2017-03-06
In response to the conjecture that the numerical aperture of x-ray optics is fundamentally limited by the critical angle of total reflection, the concept of adiabatically focusing refractive lenses was proposed to overcome this limit. Here, we present an experimental realization of these optics made of silicon and demonstrate that they indeed focus 20 keV x rays to a 18.4 nm focus with a numerical aperture of 1.73(9) × 10 –3 that clearly exceeds the critical angle of total reflection of 1.55 mrad.
Formation of a dual-stage pinch-accelerator in a Z-pinch (plasma focus) device
NASA Astrophysics Data System (ADS)
Behbahani, R. A.; Hirose, A.; Xiao, C.
2018-01-01
A novel dense plasma focus configuration with two separate concentric current sheet run-down regions has been demonstrated to produce several consecutive plasma focusing events. In a proof-of-principle experiment on a low-energy plasma focus device, the measured tube voltages and discharge current have been explained by using circuit analyses of the device. Based on the calculated plasma voltages the occurrence of flash-over phase, axial phase, and compression phase has been discussed. The electrical signals along with the calculated plasma voltages suggest the occurrence of several focusing events in the new structure.
Method of automatic measurement and focus of an electron beam and apparatus therefore
Giedt, W.H.; Campiotti, R.
1996-01-09
An electron beam focusing system, including a plural slit-type Faraday beam trap, for measuring the diameter of an electron beam and automatically focusing the beam for welding is disclosed. Beam size is determined from profiles of the current measured as the beam is swept over at least two narrow slits of the beam trap. An automated procedure changes the focus coil current until the focal point location is just below a workpiece surface. A parabolic equation is fitted to the calculated beam sizes from which optimal focus coil current and optimal beam diameter are determined. 12 figs.
Method of automatic measurement and focus of an electron beam and apparatus therefor
Giedt, Warren H.; Campiotti, Richard
1996-01-01
An electron beam focusing system, including a plural slit-type Faraday beam trap, for measuring the diameter of an electron beam and automatically focusing the beam for welding. Beam size is determined from profiles of the current measured as the beam is swept over at least two narrow slits of the beam trap. An automated procedure changes the focus coil current until the focal point location is just below a workpiece surface. A parabolic equation is fitted to the calculated beam sizes from which optimal focus coil current and optimal beam diameter are determined.
Overholt, M F; Arkfeld, E K; Wilson, K B; Mohrhauser, D A; King, D A; Wheeler, T L; Dilger, A C; Shackelford, S D; Boler, D D
2016-12-01
Objectives were to determine the effects of marketing group on quality and variability of belly and adipose tissue quality traits of pigs sourced from differing production focuses (lean vs. quality). Pigs ( = 8,042) raised in 8 barns representing 2 seasons (cold and hot) were used. Three groups were marketed from each barn with 2 barns per production focus marketed per season. Data were collected on 7,684 carcasses at a commercial abattoir. Fresh belly characteristics, American Oil Chemists' Society iodine value (AOCS-IV), and near-infrared iodine value were measured on a targeted 50, 10, and 100% of carcasses, respectively. Data were analyzed as a split-plot design in the MIXED procedure of SAS 9.4 with production focus as the whole-plot factor and marketing group as the split-plot factor. Barn (block), season, and sex were random variables. A multivariance model was fit using the REPEATED statement with the marketing group × production focus interaction as the grouping variable. Variances for production focus and marketing groups were calculated using the MEANS procedure. Homogeneity of variance was tested on raw data using the Levene's test of the GLM procedure. Among quality focus carcasses, marketing group 3 bellies weighed less ( ≤ 0.03) than those from either marketing group 1 or 2, but there was no difference ( ≥ 0.99) among marketing groups of the lean focus carcasses. There was no effect ( ≥ 0.11) of production focus on fresh belly measures, SFA, or iodine value (IV), but lean focus carcasses had decreased ( = 0.04) total MUFA and increased ( < 0.01) total PUFA compared with quality focus carcasses. Marketing group did not affect ( ≥ 0.10) fresh belly dimensions, total SFA, total MUFA, total PUFA, or IV. Belly weight, flop score, width, and all depth measurements were less variable ( ≤ 0.01); whereas, belly length, total SFA, and total MUFA were more variable ( < 0.0001) in lean focus carcasses than in quality focus carcasses. There was no difference ( ≥ 0.17) in total PUFA or AOCS-IV variability between production focuses. Variance of flop score, total MUFA, and total PUFA were not equal ( ≤ 0.01) among marketing groups. Belly weight, length, width, and depth measurements; SFA; or IV variance did not differ ( ≥ 0.06) among marketing groups. Although a multiple-marketing strategy was effective at minimizing differences in belly characteristics, differences in the variability of these traits exist among marketing groups and are likely dependent on the production system used.
Primary aberrations in focused radially polarized vortex beams
NASA Astrophysics Data System (ADS)
Biss, David P.; Brown, T. G.
2004-02-01
We study the effect of primary aberrations on the 3-D polarization of the electric field in a focused lowest order radially polarized beam. A full vector diffraction treatment of the focused beams is used. Attention is given to the effects of primary spherical, astigmatic, and comatic aberrations on the local polarization, Strehl ratio, and aberration induced degradation of the longitudinal field at focus
ERIC Educational Resources Information Center
Orman, Evelyn K.
2016-01-01
This study examined the effects of virtual reality immersion with audio on eye contact, directional focus and focus of attention for novice wind band conductors. Participants (N = 34) included a control group (n = 12) and two virtual reality groups with (n = 10) and without (n = 12) head tracking. Participants completed conducting/score study…
ERIC Educational Resources Information Center
Vicsek, Lilla
2010-01-01
In this paper I discuss some concerns related to the analysis of focus groups: (a) the issue of generalisation; (b) the problems of using numbers and quantifying in the analysis; (c) how the concrete situation of the focus groups could be included in the analysis, and (d) what formats can be used when quoting from focus groups. Problems with…
Kristell A. Miller; Stephanie A. Snyder; Mike A. Kilgore; Mae A. Davenport
2014-01-01
In 2012, focus groups were organized with individuals owning 20+ acres in the Lake States region of the United States (Michigan, Minnesota, and Wisconsin) to discuss various issues related to forest carbon offsetting. Focus group participants consisted of landowners who had responded to an earlier mail-back survey (2010) on forest carbon offsets. Two focus groups were...
Global Trend in Education: Shifting from a Teaching-Focus to a Learning-Focus.
ERIC Educational Resources Information Center
Montgomery, Joel R.
Today a global shift in education is taking place, moving from a teaching focus to a learning focus. The new vision of education centers on the learner and how teachers can assist the learner in mastering needed competencies and processes required for success in the workplace and in life. This vision looks at the learner as a decision maker,…
Corrosion-Fatigue Assessment Program
2008-03-31
22 Figure 3.2.1-4 Deep -focus image of Specimen 598-7 – Crack 1...at Feature #2 .........................22 Figure 3.2.1-5 Deep -focus image of Specimen 598-7 – Crack 2 at Feature #5 .........................23...Figure 3.2.1-6 Deep -focus image of Specimen 598-7 – Crack 3 at Feature #3 .........................23 Figure 3.2.1-7 Deep -focus image of Specimen 598-7
Toward automated analysis of particle holograms
NASA Technical Reports Server (NTRS)
Caulfield, H. J.
1987-01-01
A preliminary study of approaches for extracting and analyzing data from particle holograms is discussed. It concludes that: (1) for thin spherical particles, out-of-focus methods are optimum; (2) for thin nonspherical particles, out-of-focus methods are useful but must be supplemented by in-focus methods; (3) a complex method of projection and back projection can remove out-of-focus data for deep particles.
Nazerian, Peiman; Vanni, Simone; Morello, Fulvio; Castelli, Matteo; Ottaviani, Maddalena; Casula, Claudia; Petrioli, Alessandra; Bartolucci, Maurizio; Grifoni, Stefano
2015-05-01
The diagnostic performance of transthoracic focused cardiac ultrasound (FoCUS) performed by emergency physicians (EP) to estimate ascending aorta dimensions in the acute setting has not been prospectively studied. The diagnostic accuracy and the interobserver variability of EP-performed FoCUS were investigated to estimate thoracic aortic dilation and aneurysm compared with the results of computed tomography angiography (CTA). This was a prospective single-center cohort study of a convenience sample of patients who underwent CTA in the emergency department for suspected aortic pathology. FoCUS was performed before CTA, and the maximum ascending aorta diameter evaluated in parasternal long-axis view. Aorta diameter < 40 mm by visual estimation or by diameter measurement was considered normal. Measurements were recorded in all patients with aorta diameter ≥ 40 mm. Diagnostic accuracy of FoCUS for detection of aortic dilation (diameter ≥ 40 mm) and aneurysm (diameter ≥ 45 mm) were calculated considering the CTA result as reference standard. In a subgroup of patients, a second EP-sonographer performed FoCUS to evaluate interobserver agreement for the diagnosis of ascending aorta dilation. A total of 140 patients were enrolled in the study. Ascending aorta dilation and aneurysm were detected with FoCUS in 50 (35.7%) and in 27 (17.8%) patients, respectively. Sensitivity and specificity of FoCUS were 78.6% (95% confidence interval [CI] = 65.6% to 88.4%) and 92.9% (95% CI = 85.1% to 97.3%), respectively, for ascending aorta dilation and 64.7% (95% CI = 46.5% to 80.2%) and 95.3% (95% CI = 89.3% to 98.4%), respectively, for ascending aorta aneurysm. Interobserver agreement of FoCUS was k = 0.82. FoCUS performed by EP is specific for ascending aorta dilation and aneurysm when compared to CTA and appears a reproducible technique. © 2015 by the Society for Academic Emergency Medicine.
Minds “At Attention”: Mindfulness Training Curbs Attentional Lapses in Military Cohorts
Jha, Amishi P.; Morrison, Alexandra B.; Dainer-Best, Justin; Parker, Suzanne; Rostrup, Nina; Stanley, Elizabeth A.
2015-01-01
We investigated the impact of mindfulness training (MT) on attentional performance lapses associated with task-unrelated thought (i.e., mind wandering). Periods of persistent and intensive demands may compromise attention and increase off-task thinking. Here, we investigated if MT may mitigate these deleterious effects and promote cognitive resilience in military cohorts enduring a high-demand interval of predeployment training. To better understand which aspects of MT programs are most beneficial, three military cohorts were examined. Two of the three groups were provided MT. One group received an 8-hour, 8-week variant of Mindfulness-based Mind Fitness Training (MMFT) emphasizing engagement in training exercises (training-focused MT, n = 40), a second group received a didactic-focused variant emphasizing content regarding stress and resilience (didactic-focused MT, n = 40), and the third group served as a no-training control (NTC, n = 24). Sustained Attention to Response Task (SART) performance was indexed in all military groups and a no-training civilian group (CIV, n = 45) before (T1) and after (T2) the MT course period. Attentional performance (measured by A’, a sensitivity index) was lower in NTC vs. CIV at T2, suggesting that performance suffers after enduring a high-demand predeployment interval relative to a similar time period of civilian life. Yet, there were significantly fewer performance lapses in the military cohorts receiving MT relative to NTC, with training-focused MT outperforming didactic-focused MT at T2. From T1 to T2, A’ degraded in NTC and didactic-focused MT but remained stable in training-focused MT and CIV. In sum, while protracted periods of high-demand military training may increase attentional performance lapses, practice-focused MT programs akin to training-focused MT may bolster attentional performance more than didactic-focused programs. As such, training-focused MT programs should be further examined in cohorts experiencing protracted high-demand intervals. PMID:25671579
Carlsen, Benedicte; Glenton, Claire
2012-09-03
Despite growing support for mixed methods approaches we still have little systematic knowledge about the consequences of combining surveys and focus groups. While the methodological aspects of questionnaire surveys have been researched extensively, the characteristics of focus group methodology are understudied. We suggest and discuss whether the focus group setting, as compared to questionnaire surveys, encourages participants to exaggerate views in a negative direction. Based on an example from our own research, where we conducted a survey as a follow up of a focus group study, and with reference to theoretical approaches and empirical evidence from the literature concerning survey respondent behaviour and small group dynamics, we discuss the possibility that a discrepancy in findings between the focus groups and the questionnaire reflects characteristics of the two different research methods. In contrast to the survey, the focus group study indicated that doctors were generally negative to clinical guidelines. We were not convinced that this difference in results was due to methodological flaws in either of the studies, and discuss instead how this difference may have been the result of a general methodological phenomenon. Based on studies of how survey questionnaires influence responses, it appears reasonable to claim that surveys are more likely to find exaggerated positive views. Conversely, there are some indications in the literature that focus groups may result in complaints and overly negative attitudes, but this is still an open question. We suggest that while problematic issues tend to be under-communicated in questionnaire surveys, they may be overstated in focus groups.We argue for the importance of increasing our understanding of focus group methodology, for example by reporting interesting discrepancies in mixed methods studies. In addition, more experimental research on focus groups should be conducted to advance the methodology and to test our hypothesis.
Urban regulatory focus: a new concept linking city size to human behaviour
2018-01-01
Why do people in big cities behave differently to those living in small cities? To answer this question, in this paper a new concept of urban dynamics is presented that links city size to human behaviour. The concept has its origins in regulatory focus theory. According to the theory, goal-directed behaviour is regulated by two motivational systems, promotion and prevention. Individuals motivated by promotion goals (growth, accomplishment) focus on winning and tend to take risks, whereas those driven by prevention goals (safety, security) focus on not losing and try to avoid risk. Here we elaborate on the existing literature by linking the theory to the urban context. In our conceptualization, cities are powerful regulatory systems, and as such they impinge upon the way people regulate themselves in the urban space. Evidence from signal detection analysis is provided that supports this concept. The experience of a big-city context intensified both promotion-focused behaviour (a risky bias) for promotion-focused participants and prevention-focused behaviour (a conservative bias) for prevention-focused participants. The experience of a small-city context encouraged the opposite behavioural pattern in both cases. These findings suggest that the urban environment can influence the regulatory focus strategies of an individual in a way that cannot simply be explained by their personal regulatory focus. Specifically, the likelihood of one's behaving in a promotion- or prevention-oriented manner is dependent both on one's chronic regulatory focus and also on the urban context in which one lives. Based on this, we maintain that vibrant cities with a large population and a fast pace of life encourage extreme and polarized behaviours, whereas cities with a smaller population and a slower pace of life encourage more moderate and less polarized behavioural responses, which may explain why people in big cities take more risks, do more business, produce and spend more, and even walk faster. PMID:29892353
2012-01-01
Background Despite growing support for mixed methods approaches we still have little systematic knowledge about the consequences of combining surveys and focus groups. While the methodological aspects of questionnaire surveys have been researched extensively, the characteristics of focus group methodology are understudied. We suggest and discuss whether the focus group setting, as compared to questionnaire surveys, encourages participants to exaggerate views in a negative direction. Discussion Based on an example from our own research, where we conducted a survey as a follow up of a focus group study, and with reference to theoretical approaches and empirical evidence from the literature concerning survey respondent behaviour and small group dynamics, we discuss the possibility that a discrepancy in findings between the focus groups and the questionnaire reflects characteristics of the two different research methods. In contrast to the survey, the focus group study indicated that doctors were generally negative to clinical guidelines. We were not convinced that this difference in results was due to methodological flaws in either of the studies, and discuss instead how this difference may have been the result of a general methodological phenomenon. Summary Based on studies of how survey questionnaires influence responses, it appears reasonable to claim that surveys are more likely to find exaggerated positive views. Conversely, there are some indications in the literature that focus groups may result in complaints and overly negative attitudes, but this is still an open question. We suggest that while problematic issues tend to be under-communicated in questionnaire surveys, they may be overstated in focus groups. We argue for the importance of increasing our understanding of focus group methodology, for example by reporting interesting discrepancies in mixed methods studies. In addition, more experimental research on focus groups should be conducted to advance the methodology and to test our hypothesis. PMID:22943658
Minds "at attention": mindfulness training curbs attentional lapses in military cohorts.
Jha, Amishi P; Morrison, Alexandra B; Dainer-Best, Justin; Parker, Suzanne; Rostrup, Nina; Stanley, Elizabeth A
2015-01-01
We investigated the impact of mindfulness training (MT) on attentional performance lapses associated with task-unrelated thought (i.e., mind wandering). Periods of persistent and intensive demands may compromise attention and increase off-task thinking. Here, we investigated if MT may mitigate these deleterious effects and promote cognitive resilience in military cohorts enduring a high-demand interval of predeployment training. To better understand which aspects of MT programs are most beneficial, three military cohorts were examined. Two of the three groups were provided MT. One group received an 8-hour, 8-week variant of Mindfulness-based Mind Fitness Training (MMFT) emphasizing engagement in training exercises (training-focused MT, n = 40), a second group received a didactic-focused variant emphasizing content regarding stress and resilience (didactic-focused MT, n = 40), and the third group served as a no-training control (NTC, n = 24). Sustained Attention to Response Task (SART) performance was indexed in all military groups and a no-training civilian group (CIV, n = 45) before (T1) and after (T2) the MT course period. Attentional performance (measured by A', a sensitivity index) was lower in NTC vs. CIV at T2, suggesting that performance suffers after enduring a high-demand predeployment interval relative to a similar time period of civilian life. Yet, there were significantly fewer performance lapses in the military cohorts receiving MT relative to NTC, with training-focused MT outperforming didactic-focused MT at T2. From T1 to T2, A' degraded in NTC and didactic-focused MT but remained stable in training-focused MT and CIV. In sum, while protracted periods of high-demand military training may increase attentional performance lapses, practice-focused MT programs akin to training-focused MT may bolster attentional performance more than didactic-focused programs. As such, training-focused MT programs should be further examined in cohorts experiencing protracted high-demand intervals.
Results of ultra compact plasma focus operating in repetitive burst-mode
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shukla, R.; Shyam, A.; Verma, R.
2014-07-01
The results of a miniature plasma focus are being presented in this paper which is operated with energy less than or equal to 150 Joules. The miniature plasma focus is driven by a small capacitor bank and the peak current delivered in the focus is 75kA. The deuterium gas is filled with a pressure range of 5-7 mbar inside the plasma focus chamber. The quartz glass is used for generating initial surface breakdown at 4-5 kV discharge which is a typical value for low-voltage plasma focus discharges. The repetitive operation of the device is achieved by a combination of amore » simple and high power (5 kW) power supply with the synchronized triggering of the capacitor bank at the time of isolation between supply and the capacitor bank. As the plasma focus chamber volume is very low, in order to achieve reduced after-shot contamination effects, the gas pressure inside the plasma focus is maintained by continuous pumping which is disallowed at the time of shorts rather having a sealed type plasma focus assembly. The results of such scheme are also discussed in the paper. The diameter of cathode is 25mm and anode diameter is 8-12 mm and both of them are made of stainless steel. The length of anode and gas pressure is adjusted in such a way that the pinching occurs at the time of occurrence of the peak of current. It enhances the neutron emission from the device. The time-of-flight diagnostic is used to distinguish neutron and X-ray emission from the plasma focus. The device can serve the purpose of being a portable and compact repetitive neutron source for various applications as the flux of the radiation is comparable with the bigger devices of same type. The modeling results of plasma focus are also compared with experimental results to give a broader picture of the device. (author)« less
Titler, Marita G; Visovatti, Moira A; Shuman, Clayton; Ellis, Katrina R; Banerjee, Tanima; Dockham, Bonnie; Yakusheva, Olga; Northouse, Laurel
2017-11-01
This study examined the effectiveness, feasibility, and satisfaction with implementation of the FOCUS program in two US Cancer Support Community affiliates in Ohio and California as well as the cost to deliver the program. FOCUS is an evidence-based psychoeducational intervention for dyads (cancer patients and caregivers). A pre-post-intervention design was employed. Eleven, five-session Focus programs were delivered by licensed professionals in a small group format (three-four dyads/group) to 36 patient-caregiver dyads. An Implementation Training Manual, a FOCUS Intervention Protocol Manual, and weekly conference calls were used to foster implementation. Participants completed questionnaires prior to and following completion of each five-session FOCUS program to measure primary (emotional distress, quality of life) and secondary outcomes (benefits of illness, self-efficacy, and dyadic communication). Enrollment and retention rates and fidelity to FOCUS were used to measure feasibility. Cost estimates were based on time and median hourly wages. Repeated analysis of variance was used to analyze the effect of FOCUS on outcomes for dyads. Descriptive statistics were used to examine feasibility, satisfaction, and cost estimates. FOCUS had positive effects on QOL (p = .014), emotional (p = .012), and functional (p = .049) well-being, emotional distress (p = .002), benefits of illness (p = .013), and self-efficacy (p = .001). Intervention fidelity was 85% with enrollment and retention rates of 71.4 and 90%, respectively. Participants were highly satisfied. Cost for oversight and delivery of the five-session FOCUS program was $168.00 per dyad. FOCUS is an economic and effective intervention to decrease distress and improve the quality of life for dyads.
Dual identities: organizational negotiation in STEM-focused Catholic schools
NASA Astrophysics Data System (ADS)
Kloser, Matthew; Wilsey, Matthew; Hopkins, Dawn W.; Dallavis, Julie W.; Lavin, Erin; Comuniello, Michael
2017-06-01
In the last decade, STEM-focused schools have opened their doors nationally in the hope of meeting students' contemporary educational needs. Despite the growth of these STEM-focused institutions, minimal research exists that follows how schools make a transition toward a STEM focus and what organizational structures are most conducive to a successful transition. The adoption of a STEM focus has clear implications for a school's organizational identity. For Catholic schools, the negotiation of a new STEM focus is especially complex, as Catholic schools have been shown to generally possess a distinct religious and cultural organizational identity. The adoption of a second, STEM-focused identity raises questions about whether and how these identities can coexist. Framed by perspectives on organizational identity and existing conceptualizations of the cultural and religious hallmarks of Catholic schools, this study utilizes a multiple-case study design to explore the organizational transition of four Catholic K-8 institutions to Catholic STEM-focused schools. These cases demonstrate the particular challenges of negotiating multiple organizational identities. While variation existed in how the four schools accommodated these identities, the most promising environments for successful transition drew upon an aggregative model of identity negotiation, that is, when schools attended to both identities, but ensured that the original Catholic identity of the school remained foundational to all decisions. The least successful identity negotiations occurred when there was a lack of common understanding about what comprised a STEM-focused school, leading to minimal buy-in from stakeholders or when a school sought to make the transition for recruitment or marketing rather than mission-driven reasons. Discussion of the more successful identity aggregation provides a framework for schools within and beyond the religious sector that desire to adopt an additional STEM-focused identity.
Fuzzy control system for a remote focusing microscope
NASA Astrophysics Data System (ADS)
Weiss, Jonathan J.; Tran, Luc P.
1992-01-01
Space Station Crew Health Care System procedures require the use of an on-board microscope whose slide images will be transmitted for analysis by ground-based microbiologists. Focusing of microscope slides is low on the list of crew priorities, so NASA is investigating the option of telerobotic focusing controlled by the microbiologist on the ground, using continuous video feedback. However, even at Space Station distances, the transmission time lag may disrupt the focusing process, severely limiting the number of slides that can be analyzed within a given bandwidth allocation. Substantial time could be saved if on-board automation could pre-focus each slide before transmission. The authors demonstrate the feasibility of on-board automatic focusing using a fuzzy logic ruled-based system to bring the slide image into focus. The original prototype system was produced in under two months and at low cost. Slide images are captured by a video camera, then digitized by gray-scale value. A software function calculates an index of 'sharpness' based on gray-scale contrasts. The fuzzy logic rule-based system uses feedback to set the microscope's focusing control in an attempt to maximize sharpness. The systems as currently implemented performs satisfactorily in focusing a variety of slide types at magnification levels ranging from 10 to 1000x. Although feasibility has been demonstrated, the system's performance and usability could be improved substantially in four ways: by upgrading the quality and resolution of the video imaging system (including the use of full color); by empirically defining and calibrating the index of image sharpness; by letting the overall focusing strategy vary depending on user-specified parameters; and by fine-tuning the fuzzy rules, set definitions, and procedures used.
At Least I Tried: The Relationship between Regulatory Focus and Regret Following Action vs. Inaction
Itzkin, Adi; Van Dijk, Dina; Azar, Ofer H.
2016-01-01
Regret is an unpleasant feeling that may arise following decisions that ended poorly, and may affect the decision-maker's well-being and future decision making. Some studies show that a decision to act leads to greater regret than a decision not to act when both resulted in failure, because the latter is usually the norm. In some cases, when the norm is to act, this pattern is reversed. We suggest that the decision maker's regulatory focus, affects regret after action or inaction. Specifically, promotion-focused individuals, who tend to be more proactive, view action as more normal than prevention-focused individuals, and therefore experience regulatory fit when an action decision is made. Hence, we hypothesized that promotion-focused individuals will feel less regret than prevention-focused individuals when a decision to act ended poorly. In addition, we hypothesized that a trigger for change implied in the situation, decreases the level of regret following action. We tested our hypotheses on a sample of 330 participants enrolled in an online survey. The participants received six decision scenarios, in which they were asked to evaluate the level of regret following action and inaction. Individual regulatory focus was measured by two different scales. Promotion-focused individuals attributed less regret than prevention-focused individuals to action decisions. Regret following inaction was not affected by regulatory focus. In addition, a trigger for change decreases regret following action. Orthodox people tend to attribute more regret than non-orthodox to a person who made an action decision. The results contribute to the literature by showing that not only the situation but also the decision maker's orientation affects the regret after action vs. inaction. PMID:27833581
Past-focused temporal communication overcomes conservatives' resistance to liberal political ideas.
Lammers, Joris; Baldwin, Matt
2018-04-01
Nine studies and a meta-analysis test the role of past-focused temporal communication in reducing conservatives' disagreement with liberal political ideas. We propose that conservatives are more prone to warm, affectionate, and nostalgic feelings for past society. Therefore, they are more likely to support political ideas-including those expressing liberal values-that can be linked to a desirable past state (past focus), rather than a desirable future state (future focus) of society. Study 1 supports our prediction that political conservatives are more nostalgic for the past than liberals. Building on this association, we demonstrate that communicating liberal ideas with a past focus increases conservatives' support for leniency in criminal justice (Studies 2a and 2b), gun control (Study 3), immigration (Study 4), social diversity (Study 5), and social justice (Study 6). Communicating messages with a past focus reduced political disagreement (compared with a future focus) between liberals and conservatives by between 30 and 100% across studies. Studies 5 and 6 identify the mediating role of state and trait nostalgia, respectively. Study 7 shows that the temporal communication effect only occurs under peripheral (and not central) information processing. Study 8 shows that the effect is asymmetric; a future focus did not increase liberals' support for conservative ideas. A mixed-effects meta-analysis across all studies confirms that appealing to conservatives' nostalgia with a past-focused temporal focus increases support for liberal political messages (Study 9). A large portion of the political disagreement between conservatives and liberals appears to be disagreement over style, and not content of political issues. (PsycINFO Database Record (c) 2018 APA, all rights reserved).
Scholl, Annika; Sassenrath, Claudia; Sassenberg, Kai
2015-01-01
Depending on their motivation, individuals prefer different group contexts for social interactions. The present research sought to provide more insight into this relationship. More specifically, we tested how challenge/threat and a promotion/prevention focus predict attraction to groups with high- or low-power. As such, we examined differential outcomes of threat and prevention focus as well as challenge and promotion focus that have often been regarded as closely related. According to regulatory focus, individuals should prefer groups that they expect to “feel right” for them to join: Low-power groups should be more attractive in a prevention (than a promotion) focus, as these groups suggest security-oriented strategies, which fit a prevention focus. High-power groups should be more attractive in a promotion (rather than a prevention) focus, as these groups are associated with promotion strategies fitting a promotion focus (Sassenberg et al., 2007). In contrast, under threat (vs. challenge), groups that allow individuals to restore their (perceived) lack of control should be preferred: Low-power groups should be less attractive under threat (than challenge) because they provide low resources which threatened individuals already perceive as insufficient and high-power groups might be more attractive under threat (than under challenge), because their high resources allow individuals to restore control. Two experiments (N = 140) supported these predictions. The attractiveness of a group often depends on the motivation to engage in what fits (i.e., prefer a group that feels right in the light of one’s regulatory focus). However, under threat the striving to restore control (i.e., prefer a group allowing them to change the status quo under threat vs. challenge) overrides the fit effect, which may in turn guide individuals’ behavior in social interactions. PMID:25904887
Hard TiCx/SiC/a-C:H nanocomposite thin films using pulsed high energy density plasma focus device
NASA Astrophysics Data System (ADS)
Umar, Z. A.; Rawat, R. S.; Tan, K. S.; Kumar, A. K.; Ahmad, R.; Hussain, T.; Kloc, C.; Chen, Z.; Shen, L.; Zhang, Z.
2013-04-01
Thin films of TiCx/SiC/a-C:H were synthesized on Si substrates using a complex mix of high energy density plasmas and instability accelerated energetic ions of filling gas species, emanated from hot and dense pinched plasma column, in dense plasma focus device. The conventional hollow copper anode of Mather type plasma focus device was replaced by solid titanium anode for synthesis of TiCx/SiC/a-C:H nanocomposite thin films using CH4:Ar admixture of (1:9, 3:7 and 5:5) for fixed 20 focus shots as well as with different number of focus shots with fixed CH4:Ar admixture ratio 3:7. XRD results showed the formation of crystalline TiCx/SiC phases for thin film synthesized using different number of focus shots with CH4:Ar admixture ratio fixed at 3:7. SEM results showed that the synthesized thin films consist of nanoparticle agglomerates and the size of agglomerates depended on the CH4:Ar admixture ratio as well as on the number of focus shots. Raman analysis showed the formation of polycrystalline/amorphous Si, SiC and a-C for different CH4:Ar ratio as well as for different number of focus shots. The XPS analysis confirmed the formation of TiCx/SiC/a-C:H composite thin film. Nanoindentation results showed that the hardness and elastic modulus values of composite thin films increased with increasing number of focus shots. Maximum values of hardness and elastic modulus at the surface of the composite thin film were found to be about 22 and 305 GPa, respectively for 30 focus shots confirming the successful synthesis of hard composite TiCx/SiC/a-C:H coatings.
Mental Health Advisory Team-Korea (8th Army) Technical Report
2016-06-30
10 2.3 Comparison Groups for Analyses...10 2.4 Focus Groups ............................................................................................................... 11...46 8.7 Perceptions of Staffing Challenges: Survey and Focus Group Data .............................. 48 9 SOLDIER FOCUS GROUP SUMMARY
Public Participation Guide: Focus Groups
A focus group is a small group discussion with professional leadership. Focus groups are used to find out what issues are of most concern for a community or group when little or no information is available.
Li, Chenwei; Wu, Keke 'Coco'; Johnson, Diane E
2018-02-01
Based on gender role expectations model, we examined how balance-focused attitudes would affect job stress by influencing individuals' perceptions of family interference with work (FIW), and investigated whether a gender difference would exist in the relationships among balance-focused attitudes, FIW and job stress. Using two independent samples from the United States and China, we found support for the indirect influence of balance-focused attitudes on job stress, through FIW. Participants with balance-focused attitudes experienced lower levels of job stress as they perceived less interference from family to work. As expected, such indirect effect was more pronounce among male participants, meaning that the male participants benefited more from having balance-focused attitudes. Discussion, theoretical and practical implications are provided. © 2016 International Union of Psychological Science.
Su, Luning; Li, Wei; Wu, Mingxuan; Su, Yun; Guo, Chongling; Ruan, Ningjuan; Yang, Bingxin; Yan, Feng
2017-08-01
Lobster-eye optics is widely applied to space x-ray detection missions and x-ray security checks for its wide field of view and low weight. This paper presents a theoretical model to obtain spatial distribution of focusing efficiency based on lobster-eye optics in a soft x-ray wavelength. The calculations reveal the competition mechanism of contributions to the focusing efficiency between the geometrical parameters of lobster-eye optics and the reflectivity of the iridium film. In addition, the focusing efficiency image depending on x-ray wavelengths further explains the influence of different geometrical parameters of lobster-eye optics and different soft x-ray wavelengths on focusing efficiency. These results could be beneficial to optimize parameters of lobster-eye optics in order to realize maximum focusing efficiency.
Hatori, Tsuyoshi; Takemura, Kazuhisa; Fujii, Satoshi; Ideno, Takashi
2011-06-01
This paper presents a new model of category judgment. The model hypothesizes that, when more attention is focused on a category, the psychological range of the category gets narrower (category-focusing hypothesis). We explain this hypothesis by using the metaphor of a "mental-box" model: the more attention that is focused on a mental box (i.e., a category set), the smaller the size of the box becomes (i.e., a cardinal number of the category set). The hypothesis was tested in an experiment (N = 40), where the focus of attention on prescribed verbal categories was manipulated. The obtained data gave support to the hypothesis: category-focusing effects were found in three experimental tasks (regarding the category of "food", "height", and "income"). The validity of the hypothesis was discussed based on the results.
Neubert, Mitchell J; Kacmar, K Michele; Carlson, Dawn S; Chonko, Lawrence B; Roberts, James A
2008-11-01
In this research, the authors test a model in which the regulatory focus of employees at work mediates the influence of leadership on employee behavior. In a nationally representative sample of 250 workers who responded over 2 time periods, prevention focus mediated the relationship of initiating structure to in-role performance and deviant behavior, whereas promotion focus mediated the relationship of servant leadership to helping and creative behavior. The results indicate that even though initiating structure and servant leadership share some variance in explaining other variables, each leadership style incrementally predicts disparate outcomes after controlling for the other style and dispositional tendencies. A new regulatory focus scale, the Work Regulatory Focus (WRF) Scale, also was developed and initially validated for this study. Implications for the results and the WRF Scale are discussed.
Generation of scalable terahertz radiation from cylindrically focused two-color laser pulses in air
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kuk, D.; Yoo, Y. J.; Rosenthal, E. W.
2016-03-21
We demonstrate scalable terahertz (THz) generation by focusing terawatt, two-color laser pulses in air with a cylindrical lens. This focusing geometry creates a two-dimensional air plasma sheet, which yields two diverging THz lobe profiles in the far field. This setup can avoid plasma-induced laser defocusing and subsequent THz saturation, previously observed with spherical lens focusing of high-power laser pulses. By expanding the plasma source into a two-dimensional sheet, cylindrical focusing can lead to scalable THz generation. This scheme provides an energy conversion efficiency of 7 × 10{sup −4}, ∼7 times better than spherical lens focusing. The diverging THz lobes are refocused withmore » a combination of cylindrical and parabolic mirrors to produce strong THz fields (>21 MV/cm) at the focal point.« less
SAFT-assisted sound beam focusing using phased arrays (PA-SAFT) for non-destructive evaluation
NASA Astrophysics Data System (ADS)
Nanekar, Paritosh; Kumar, Anish; Jayakumar, T.
2015-04-01
Focusing of sound has always been a subject of interest in ultrasonic non-destructive evaluation. An integrated approach to sound beam focusing using phased array and synthetic aperture focusing technique (PA-SAFT) has been developed in the authors' laboratory. The approach involves SAFT processing on ultrasonic B-scan image collected by a linear array transducer using a divergent sound beam. The objective is to achieve sound beam focusing using fewer elements than the ones required using conventional phased array. The effectiveness of the approach is demonstrated on aluminium blocks with artificial flaws and steel plate samples with embedded volumetric weld flaws, such as slag and clustered porosities. The results obtained by the PA-SAFT approach are found to be comparable to those obtained by conventional phased array and full matrix capture - total focusing method approaches.
Enhanced focus steering abilities of multi-element therapeutic arrays operating in nonlinear regimes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yuldashev, P., E-mail: petr@acs366.phys.msu.ru; Ilyin, S.; Gavrilov, L.
2015-10-28
Steering abilities of a typical HIFU therapeutic array operated in linear and nonlinear regimes were compared using numerical simulation with the 3D Westervelt equation. The array included 256 elements of 1.2 MHz frequency and 6.6 mm diameter distributed in a quasi-random pattern over a spherical shell with a 130 mm aperture and a focal length of 120 mm. In the case of linear focusing, thermal effects are proportional to the intensity level and the criterion for safe array operation is that the intensity in the grating lobes should be less than 10% of the intensity in the main focus. Inmore » the case of nonlinear focusing, the heating effect is no longer proportional to intensity; therefore the heat deposition rate was chosen as the relevant metric, using the same 10% threshold for the secondary lobe in comparison with the focal maximum. When steering the focus, the same linearly predicted intensity level at the main focus was maintained by increasing the array power. Numerical simulations of the acoustic field were performed for nonlinear propagation both in water and in tissue. It was shown that for shock-forming conditions in the main focus, the steering range of safe electronic focusing is larger than that for linear propagation conditions. Nonlinear sonication regimes therefore can be used to enlarge tissue volumes that can be sonicated using electronic steering of the focus of HIFU arrays.« less
Design of voice coil motor dynamic focusing unit for a laser scanner
NASA Astrophysics Data System (ADS)
Lee, Moon G.; Kim, Gaeun; Lee, Chan-Woo; Lee, Soo-Hun; Jeon, Yongho
2014-04-01
Laser scanning systems have been used for material processing tasks such as welding, cutting, marking, and drilling. However, applications have been limited by the small range of motion and slow speed of the focusing unit, which carries the focusing optics. To overcome these limitations, a dynamic focusing system with a long travel range and high speed is needed. In this study, a dynamic focusing unit for a laser scanning system with a voice coil motor (VCM) mechanism is proposed to enable fast speed and a wide focusing range. The VCM has finer precision and higher speed than conventional step motors and a longer travel range than earlier lead zirconium titanate actuators. The system has a hollow configuration to provide a laser beam path. This also makes it compact and transmission-free and gives it low inertia. The VCM's magnetics are modeled using a permeance model. Its design parameters are determined by optimization using the Broyden-Fletcher-Goldfarb-Shanno method and a sequential quadratic programming algorithm. After the VCM is designed, the dynamic focusing unit is fabricated and assembled. The permeance model is verified by a magnetic finite element method simulation tool, Maxwell 2D and 3D, and by measurement data from a gauss meter. The performance is verified experimentally. The results show a resolution of 0.2 μm and travel range of 16 mm. These are better than those of conventional focusing systems; therefore, this focusing unit can be applied to laser scanning systems for good machining capability.
Design of voice coil motor dynamic focusing unit for a laser scanner.
Lee, Moon G; Kim, Gaeun; Lee, Chan-Woo; Lee, Soo-Hun; Jeon, Yongho
2014-04-01
Laser scanning systems have been used for material processing tasks such as welding, cutting, marking, and drilling. However, applications have been limited by the small range of motion and slow speed of the focusing unit, which carries the focusing optics. To overcome these limitations, a dynamic focusing system with a long travel range and high speed is needed. In this study, a dynamic focusing unit for a laser scanning system with a voice coil motor (VCM) mechanism is proposed to enable fast speed and a wide focusing range. The VCM has finer precision and higher speed than conventional step motors and a longer travel range than earlier lead zirconium titanate actuators. The system has a hollow configuration to provide a laser beam path. This also makes it compact and transmission-free and gives it low inertia. The VCM's magnetics are modeled using a permeance model. Its design parameters are determined by optimization using the Broyden-Fletcher-Goldfarb-Shanno method and a sequential quadratic programming algorithm. After the VCM is designed, the dynamic focusing unit is fabricated and assembled. The permeance model is verified by a magnetic finite element method simulation tool, Maxwell 2D and 3D, and by measurement data from a gauss meter. The performance is verified experimentally. The results show a resolution of 0.2 μm and travel range of 16 mm. These are better than those of conventional focusing systems; therefore, this focusing unit can be applied to laser scanning systems for good machining capability.
Keller, Johannes; Mayo, Ruth; Greifeneder, Rainer; Pfattheicher, Stefan
2015-01-01
The current research suggests that taking self-regulatory mechanisms into account provides insights regarding individuals' responses to threats in social interactions. In general, based on the notion that a prevention-focused orientation of self-regulation is associated with a need for security and a vigilant tendency to avoid losses and other types of negative events we advocate that a prevention-focused orientation, both as a disposition as well as a situationally induced state, lowers generalized trust, thus hindering cooperation within social interactions that entail threats. Specifically, we found that the more individuals' habitual self-regulatory orientation is dominated by a prevention focus, the less likely they are to score high on a self-report measure of generalized trust (Study 1), and to express trust in a trust game paradigm as manifested in lower sums of transferred money (Studies 2 and 3). Similar findings were found when prevention focus was situationally manipulated (Study 4). Finally, one possible factor underlying the impact of prevention-focused self-regulation on generalized trust was demonstrated as individuals with a special sensitivity to negative information were significantly affected by a subtle prevention focus manipulation (versus control condition) in that they reacted with reduced trust in the trust game (Study 5). In sum, the current findings document the crucial relevance of self-regulatory orientations as conceptualized in regulatory focus theory regarding generalized trust and responses to threats within a social interaction. The theoretical and applied implications of the findings are discussed.
Rutz, Matt A; Clary, Julie M; Kline, Jeffrey A; Russell, Frances M
2017-07-01
Focused cardiac ultrasound (FOCUS) is a useful tool in evaluating patients presenting to the emergency department (ED) with acute dyspnea. Prior work has shown that right ventricular (RV) dilation is associated with repeat hospitalizations and shorter life expectancy. Traditionally, RV assessment has been evaluated by cardiologist-interpreted comprehensive echocardiography. The primary goal of this study was to determine the inter-rater reliability between emergency physicians (EPs) and a cardiologist for determining RV dilation on FOCUS performed on ED patients with acute dyspnea. This was a prospective, observational study at two urban academic EDs; patients were enrolled if they had acute dyspnea and a computed tomographic pulmonary angiogram without acute disease. All patients had an EP-performed FOCUS to assess for RV dilation. RV dilation was defined as an RV to left ventricular ratio greater than 1. FOCUS interpretations were compared to a blinded cardiologist FOCUS interpretation using agreement and kappa statistics. Of 84 FOCUS examinations performed on 83 patients, 17% had RV dilation. Agreement and kappa, for EP-performed FOCUS for RV dilation were 89% (95% confidence interval [CI] 80-95%) and 0.68 (95% CI 0.48-0.88), respectively. Emergency physician sonographers are able to detect RV dilation with good agreement when compared to cardiology. These results support the wider use of EP-performed FOCUS to evaluate for RV dilation in ED patients with dyspnea. © 2017 by the Society for Academic Emergency Medicine.
Optical compensation for night myopia based on dark focus and CA/C ratio.
Kotulak, J C; Morse, S E; Rabin, J C
1995-07-01
To determine whether individual differences in dark focus and convergence accommodation to convergence (CA/C) ratio can be used to prescribe the best optical correction for night myopia. The best correction for night myopia was obtained by measuring visual acuity and contrast sensitivity across a range of lens powers and luminances. Dark focus was measured with an infrared optometer, and CA/C ratio was measured with an infrared optometer and eyetracker. Only young subjects were used (mean age = 25.4 years). Optimal lens power was significantly correlated with dark focus, regardless of CA/C ratio. However, the slope of the regression line relating lens power to dark focus was steeper for subjects with CA/C ratios less than 0.4 diopters/meter angle (D/MA, n = 7) than for subjects with CA/C ratios greater than 0.4 D/MA (n = 9). The mean CA/C ratio for the entire sample (n = 16) was 0.59 D/MA. The mean optimal lens power and dark focus were -0.79 and 0.74 D, respectively, for the low CA/C group, and -0.60 and 0.91 D, respectively, for the high CA/C group. Visual performance in night myopia can be optimized by taking into account intersubject differences in dark focus and CA/C ratio. Best visual performance was found with a lens roughly equaling the full dark focus for subjects with low CA/C ratios and half the dark focus for subjects with high CA/C ratios.
2017-01-01
When individuals are highly committed to their romantic relationship, they are more likely to engage in pro-relationship maintenance mechanisms. The present research expanded on the notion that commitment redirects self-oriented goals to consider broader relational goals and examined whether commitment interacts with a promotion and prevention focus to activate derogation of attractive alternatives. Three studies used cross-sectional and experimental approaches. Study 1 showed that romantically involved individuals predominantly focused on promotion, but not prevention, reported less initial attraction to an attractive target than single individuals, especially when highly committed to their relationship. Study 2 showed that romantically involved individuals induced in a promotion focus, compared to those in prevention focus, reported less initial attraction, but only when more committed to their relationship. Regardless of regulatory focus manipulation, more committed individuals were also less likely to perceive quality among alternative scenarios and to be attentive to alternative others in general. Finally, Study 3 showed that romantically involved individuals induced in promotion focus and primed with high commitment reported less initial attraction, than those primed with low commitment, or than those induced in prevention focus. Once again, for these latter no differences occurred according to commitment prime. Together, the findings suggest that highly committed promotion focused individuals consider broader relationship goals and activate relationship maintenance behaviors such as derogation of attractive alternatives to promote their relationship. PMID:28319147
2014-02-11
of refraction in the region of the “lens”, successfully focusing surface plasmon polaritons (SPP). SUPERABSORBERS: The team used the Rigorous Coupled...PLASMONIC FOCUSING: The team constructed a device capable of splitting and focusing surface plasmon polaritons into different locations depending on the...surface plasmon polaritons , plasmonics 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF ABSTRACT SAR 18, NUMBER OF PAGES 19 19a. NAME
The Effects of Focus on Forms and Focus on Form in Teaching Complex Grammatical Structures
ERIC Educational Resources Information Center
Pawlak, Miroslaw
2012-01-01
The classroom-based study reported in the present paper sought to compare the effectiveness of the focus on forms (FonFs) and focus on form (FonF) approach in teaching English third conditional to Polish high school students. It involved three intact classes, randomly designated as FonF (n = 34), FonFs (n = 36), and Control (n = 35) with a pretest…
Thermal refraction focusing in planar index-antiguided lasers.
Casperson, Lee W; Dittli, Adam; Her, Tsing-Hua
2013-03-15
Thermal refraction focusing in planar index-antiguided lasers is investigated both theoretically and experimentally. An analytical model based on zero-field approximation is presented for treating the combined effects of index antiguiding and thermal focusing. At very low pumping power, the mode is antiguided by the amplifier boundary, whereas at high pumping power it narrows due to thermal focusing. Theoretical results are in reasonable agreement with experimental data.
ERIC Educational Resources Information Center
Alwardt, Randi Kay
2011-01-01
This investigation examined the transition from a spiral science curriculum to a field-focus science curriculum in middle school. A spiral science curriculum focuses on a small part of each field of science during each middle school year, more of a general science concept. In contrast to that, the base of a field-focus curriculum is that each…
Shape-from-focus by tensor voting.
Hariharan, R; Rajagopalan, A N
2012-07-01
In this correspondence, we address the task of recovering shape-from-focus (SFF) as a perceptual organization problem in 3-D. Using tensor voting, depth hypotheses from different focus operators are validated based on their likelihood to be part of a coherent 3-D surface, thereby exploiting scene geometry and focus information to generate reliable depth estimates. The proposed method is fast and yields significantly better results compared with existing SFF methods.
ERIC Educational Resources Information Center
Wood, Jeffrey J.; McLeod, Bryce D.; Piacentini, John C.; Sigman, Marian
2009-01-01
Objective: To compare the relative long-term benefit of family-focused cognitive behavioral therapy (FCBT) and child-focused cognitive behavioral therapy (CCBT) for child anxiety disorders at a 1-year follow-up. Method: Thirty-five children (6-13 years old) randomly assigned to 12-16 sessions of family-focused CBT (FCBT) or child-focused CBT…
ERIC Educational Resources Information Center
Galliott, Natal'ya; Graham, Linda J.
2016-01-01
This paper illustrates the use of exploratory focus groups to inform the development of a survey instrument in a sequential phase mixed-methods study investigating differences in secondary students' career choice capability. Five focus groups were conducted with 23 Year 10 students in the state of New South Wales, Australia. Analysis of the focus…
Current Interruption and Particle Beam Generation by a Plasma Focus.
1982-11-30
Through collaboration with Dr. K. H. Schoenbach of Texas Tech University the plasma focus opening switch (PFOS) was revised to answer basic questions...results are consistent with the snowplow model. The final analysis of the plasma focus particle beam generation experiments was completed and a...strong correlation was found for the beam-target model as the mechanism for neutron production in the Illinois plasma focus device. (Author)
Knafl, Kathleen A.; Deatrick, Janet A.; Knafl, George J.; Gallo, Agatha M.; Grey, Margaret; Dixon, Jane
2015-01-01
Understanding patterns of family response to childhood chronic conditions based on a configuration of multiple variables or qualitative themes provides a comprehensive understanding of health-related challenges and their influence on family and child functioning. In this paper, we used the six scales comprising the Family Management Measure (FaMM) in a cluster analysis to describe a typology of family management and data from other measures of child and family functioning to validate and explain those clusters. The sample of 575 parents from 414 families of children who had diverse chronic conditions endorsed four patterns of response (Family Focused, Somewhat Family Focused, Somewhat Condition Focused, Condition Focused). We also considered the extent to which couples had shared or discrepant views of family management. Most (57%) families were in either the Family Focused or Somewhat Family Focused pattern. Single mothers were significantly less likely to be in the two patterns reflecting greater ease in family management and significantly more likely to be in the two patterns reflecting more difficulty. Patterns of family management were related significantly to family and child functioning, with families in the Family Focused and Somewhat Family Focused patterns demonstrating significantly better family and child functioning than families in the other two patterns. PMID:23602651
Analysis of phase conjugation in a turbid medium
NASA Astrophysics Data System (ADS)
Hollmann, Joseph L.; Cantero, Sergio; Tseng, Snow; DiMarzio, Charles A.
2014-03-01
The ability to focus light in most tissue degrades quickly with depth due to high optical scattering. Recently, researchers have found they can concentrate light tightly despite these scattering effects by using a guidestar and optical phase conjugation to focus light to greater distances in tissue. An optical or probe signal is transmitted through a scattering medium and its resulting wavefront is detected. The wavefront is then conjugated and utilized as a new optical source or delivery wave that focuses back to the guidestar's location with minimal scattering. The power in the delivery wave may be greatly increased for enhanced energy delivery at the focus. Modulation by an ultrasound (US) beam may be utilized to generate the guidestar dynamically and allow for US-resolution at depths of several millimeters. The delivery wave is successful at focusing light back at the guidestar because it creates constructive interference at the desired focus. However, if the phases of the field contributions change, we expect the delivered power at the focus to be reduced. This paper will analyze the robustness of this method when the probe beam is at one wavelength and the delivery wave is at another. This will allow us to characterize the deleterious effects of varying the phase contributions at the focus.
Utilizing Light-field Imaging Technology in Neurosurgery.
Chen, Brian R; Buchanan, Ian A; Kellis, Spencer; Kramer, Daniel; Ohiorhenuan, Ifije; Blumenfeld, Zack; Grisafe Ii, Dominic J; Barbaro, Michael F; Gogia, Angad S; Lu, James Y; Chen, Beverly B; Lee, Brian
2018-04-10
Traditional still cameras can only focus on a single plane for each image while rendering everything outside of that plane out of focus. However, new light-field imaging technology makes it possible to adjust the focus plane after an image has already been captured. This technology allows the viewer to interactively explore an image with objects and anatomy at varying depths and clearly focus on any feature of interest by selecting that location during post-capture viewing. These images with adjustable focus can serve as valuable educational tools for neurosurgical residents. We explore the utility of light-field cameras and review their strengths and limitations compared to other conventional types of imaging. The strength of light-field images is the adjustable focus, as opposed to the fixed-focus of traditional photography and video. A light-field image also is interactive by nature, as it requires the viewer to select the plane of focus and helps with visualizing the three-dimensional anatomy of an image. Limitations include the relatively low resolution of light-field images compared to traditional photography and video. Although light-field imaging is still in its infancy, there are several potential uses for the technology to complement traditional still photography and videography in neurosurgical education.
Utilizing Light-field Imaging Technology in Neurosurgery
Chen, Brian R; Kellis, Spencer; Kramer, Daniel; Ohiorhenuan, Ifije; Blumenfeld, Zack; Grisafe II, Dominic J; Barbaro, Michael F; Gogia, Angad S; Lu, James Y; Chen, Beverly B; Lee, Brian
2018-01-01
Traditional still cameras can only focus on a single plane for each image while rendering everything outside of that plane out of focus. However, new light-field imaging technology makes it possible to adjust the focus plane after an image has already been captured. This technology allows the viewer to interactively explore an image with objects and anatomy at varying depths and clearly focus on any feature of interest by selecting that location during post-capture viewing. These images with adjustable focus can serve as valuable educational tools for neurosurgical residents. We explore the utility of light-field cameras and review their strengths and limitations compared to other conventional types of imaging. The strength of light-field images is the adjustable focus, as opposed to the fixed-focus of traditional photography and video. A light-field image also is interactive by nature, as it requires the viewer to select the plane of focus and helps with visualizing the three-dimensional anatomy of an image. Limitations include the relatively low resolution of light-field images compared to traditional photography and video. Although light-field imaging is still in its infancy, there are several potential uses for the technology to complement traditional still photography and videography in neurosurgical education. PMID:29888163
Stable two-plane focusing for emittance-dominated sheet-beam transport
NASA Astrophysics Data System (ADS)
Carlsten, B. E.; Earley, L. M.; Krawczyk, F. L.; Russell, S. J.; Potter, J. M.; Ferguson, P.; Humphries, S.
2005-06-01
Two-plane focusing of sheet electron beams will be an essential technology for an emerging class of high-power, 100 to 300 GHz rf sources [Carlsten et al., IEEE Trans. Plasma Sci. 33, 85 (2005), ITPSBD, 0093-3813, 10.1109/TPS.2004.841172]. In these devices, the beam has a unique asymmetry in which the transport is emittance dominated in the sheet’s thin dimension and space-charge dominated in the sheet’s wide dimension. Previous work has studied the stability of the transport of beams in the emittance-dominated regime for both wiggler and periodic permanent magnet (PPM) configurations with single-plane focusing, and has found that bigger envelope scalloping occurs for equilibrium transport, as compared to space-charge dominated beams [Carlsten et al., this issue, Phys. Rev. ST Accel. Beams 8, 062001 (2005), PRABFM, 1098-4402]. In this paper, we describe the differences in transport stability when two-plane focusing is included. Two-plane wiggler focusing degrades the transport stability slightly, whereas two-plane PPM focusing greatly compromises the transport. On the other hand, single-plane PPM focusing can be augmented with external quadrupole fields to provide weak focusing in the sheet’s wide dimension, which has stability comparable to two-plane wiggler transport.
Coenen, Michaela; Stamm, Tanja A; Stucki, Gerold; Cieza, Alarcos
2012-03-01
To compare two different approaches to performing focus groups and individual interviews, an open approach, and an approach based on the International Classification of Functioning, Disability and Health (ICF). Patients with rheumatoid arthritis attended focus groups (n = 49) and individual interviews (n = 21). Time, number of concepts, ICF categories identified, and sample size for reaching saturation of data were compared. Descriptive statistics, Chi-square tests, and independent t tests were performed. With an overall time of 183 h, focus groups were more time consuming than individual interviews (t = 9.782; P < 0.001). In the open approach, 188 categories in the focus groups and 102 categories in the interviews were identified compared to the 231 and 110 respective categories identified in the ICF-based approach. Saturation of data was reached after performing five focus groups and nine individual interviews in the open approach and five focus groups and 12 individual interviews in the ICF-based approach. The method chosen should depend on the objective of the study, issues related to the health condition, and the study's participants. We recommend performing focus groups if the objective of the study is to comprehensively explore the patient perspective.
Tanks Focus Area annual report FY2000
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
2000-12-01
The U.S. Department of Energy (DOE) continues to face a major radioactive waste tank remediation effort with tanks containing hazardous and radioactive waste resulting from the production of nuclear materials. With some 90 million gallons of waste in the form of solid, sludge, liquid, and gas stored in 287 tanks across the DOE complex, containing approximately 650 million curies, radioactive waste storage tank remediation is the nation's highest cleanup priority. Differing waste types and unique technical issues require specialized science and technology to achieve tank cleanup in an environmentally acceptable manner. Some of the waste has been stored for overmore » 50 years in tanks that have exceeded their design lives. The challenge is to characterize and maintain these contents in a safe condition and continue to remediate and close each tank to minimize the risks of waste migration and exposure to workers, the public, and the environment. In 1994, the DOE's Office of Environmental Management (EM) created a group of integrated, multiorganizational teams focusing on specific areas of the EM cleanup mission. These teams have evolved into five focus areas managed within EM's Office of Science and Technology (OST): Tanks Focus Area (TFA); Deactivation and Decommissioning Focus Area; Nuclear Materials Focus Area; Subsurface Contaminants Focus Area; and Transuranic and Mixed Waste Focus Area.« less
Variable magnification variable dispersion glancing incidence imaging x-ray spectroscopic telescope
NASA Technical Reports Server (NTRS)
Hoover, Richard B. (Inventor)
1991-01-01
A variable magnification variable dispersion glancing incidence x-ray spectroscopic telescope capable of multiple high spatial revolution imaging at precise spectral lines of solar and stellar x-ray and extreme ultraviolet radiation sources includes a pirmary optical system which focuses the incoming radiation to a primary focus. Two or more rotatable carries each providing a different magnification are positioned behind the primary focus at an inclination to the optical axis, each carrier carrying a series of ellipsoidal diffraction grating mirrors each having a concave surface on which the gratings are ruled and coated with a mutlilayer coating to reflect by diffraction a different desired wavelength. The diffraction grating mirrors of both carriers are segments of ellipsoids having a common first focus coincident with the primary focus. A contoured detector such as an x-ray sensitive photogrpahic film is positioned at the second respective focus of each diffraction grating so that each grating may reflect the image at the first focus to the detector at the second focus. The carriers are selectively rotated to position a selected mirror for receiving radiation from the primary optical system, and at least the first carrier may be withdrawn from the path of the radiation to permit a selected grating on the second carrier to receive radiation.
Variable magnification variable dispersion glancing incidence imaging x ray spectroscopic telescope
NASA Technical Reports Server (NTRS)
Hoover, Richard (Inventor)
1990-01-01
A variable magnification variable dispersion glancing incidence x ray spectroscopic telescope capable of multiple high spatial revolution imaging at precise spectral lines of solar and stellar x ray and extreme ultraviolet radiation sources includes a primary optical system which focuses the incoming radiation to a primary focus. Two or more rotatable carriers each providing a different magnification are positioned behind the primary focus at an inclination to the optical axis, each carrier carrying a series of ellipsoidal diffraction grating mirrors each having a concave surface on which the gratings are ruled and coated with a multilayer coating to reflect by diffraction a different desired wavelength. The diffraction grating mirrors of both carriers are segments of ellipsoids having a common first focus coincident with the primary focus. A contoured detector such as an x ray sensitive photographic film is positioned at the second respective focus of each diffraction grating so that each grating may reflect the image at the first focus to the detector at the second focus. The carriers are selectively rotated to position a selected mirror for receiving radiation from the primary optical system, and at least the first carrier may be withdrawn from the path of the radiation to permit a selected grating on the second carrier to receive radiation.
Laser focus compensating sensing and imaging device
Vann, Charles S.
1993-01-01
A laser focus compensating sensing and imaging device permits the focus of a single focal point of different frequency laser beams emanating from the same source point. In particular it allows the focusing of laser beam originating from the same laser device but having differing intensities so that a low intensity beam will not convert to a higher frequency when passing through a conversion crystal associated with the laser generating device. The laser focus compensating sensing and imaging device uses a cassegrain system to fold the lower frequency, low intensity beam back upon itself so that it will focus at the same focal point as a high intensity beam. An angular tilt compensating lens is mounted about the secondary mirror of the cassegrain system to assist in alignment. In addition cameras or CCD's are mounted with the primary mirror to sense the focused image. A convex lens is positioned co-axial with the cassegrain system on the side of the primary mirror distal of the secondary for use in aligning a target with the laser beam. A first alternate embodiment includes a cassegrain system using a series of shutters and an internally mounted dichroic mirror. A second alternate embodiment uses two laser focus compensating sensing and imaging devices for aligning a moving tool with a work piece.
Xiao, Fengqiu; Zheng, Zhiwei; Zhang, Heyi; Xin, Ziqiang; Chen, Yinghe; Li, Yiwei
2016-01-01
Prosocial behavior refers to a broad category of actions that benefit other people or the society. Compared with other factors that affect prosocial performance, prosocial outcomes, consisting of prosocial gains and prosocial non-losses have received less attention up to now. In the current research, we explored the influences of different types of expected outcomes and regulatory focus on prosocial performance. Studies 1a and 1b examined the differences in prosocial performance elicited by prosocial gain (e.g., enhancing others' access to clean water) and prosocial non-loss outcomes (e.g., protecting others from suffering dirty water). We found that the expected prosocial non-loss outcomes induced greater prosocial performance compared with the expected prosocial gain outcomes. Studies 2a and 2b examined the effects of dispositional and situational regulatory focus on prosocial loss aversion. We found that differences in prosocial performance between two expected prosocial outcomes were reduced when promotion focus was primed; whereas a primed prevention focus did not significantly increase this difference. Additionally, participants displayed a greater prosocial loss aversion in the prevention focus condition than in the promotion focus condition. The reason for the non-significant interaction between regulatory focus and expected prosocial outcome was discussed.
Keefe, John R; Solomonov, Nili; Derubeis, Robert J; Phillips, Alexander C; Busch, Fredric N; Barber, Jacques P; Chambless, Dianne L; Milrod, Barbara L
2018-04-18
This study examines whether, in panic-focused psychodynamic psychotherapy (PFPP), interpretations of conflicts that underlie anxiety (panic-focused or PF-interpretations) are specifically associated with subsequent panic disorder (PD) symptom improvement, over and above the provision of non-symptom-focused interpretations. Technique use in Sessions 2 and 10 of a 24-session PFPP protocol was assessed for the 65 patients with complete outcome data randomized to PFPP in a two-site trial of psychotherapies for PD. Sessions were rated in 15-min segments for therapists' use of PF-interpretations, non-PF-interpretations, and PF-clarifications. Robust regressions were conducted to examine the relationship between these interventions and symptom change subsequent to the sampled session. Interpersonal problems were examined as a moderator of the relationship of PF-interpretations to symptom change. At Session 10, but not at Session 2, patients who received a higher degree of PF-interpretations experienced greater subsequent improvement in panic symptoms. Non-PF-interpretations were not predictive. Patients with more interpersonal distress benefitted particularly from the use of PF-interpretations at Session 10. By the middle phase of PFPP, panic-focused interpretations may drive subsequent improvements in panic symptoms, especially among patients with higher interpersonal distress. Interpretations of conflict absent a panic focus may not be especially helpful.
Xiao, Fengqiu; Zheng, Zhiwei; Zhang, Heyi; Xin, Ziqiang; Chen, Yinghe; Li, Yiwei
2016-01-01
Prosocial behavior refers to a broad category of actions that benefit other people or the society. Compared with other factors that affect prosocial performance, prosocial outcomes, consisting of prosocial gains and prosocial non-losses have received less attention up to now. In the current research, we explored the influences of different types of expected outcomes and regulatory focus on prosocial performance. Studies 1a and 1b examined the differences in prosocial performance elicited by prosocial gain (e.g., enhancing others’ access to clean water) and prosocial non-loss outcomes (e.g., protecting others from suffering dirty water). We found that the expected prosocial non-loss outcomes induced greater prosocial performance compared with the expected prosocial gain outcomes. Studies 2a and 2b examined the effects of dispositional and situational regulatory focus on prosocial loss aversion. We found that differences in prosocial performance between two expected prosocial outcomes were reduced when promotion focus was primed; whereas a primed prevention focus did not significantly increase this difference. Additionally, participants displayed a greater prosocial loss aversion in the prevention focus condition than in the promotion focus condition. The reason for the non-significant interaction between regulatory focus and expected prosocial outcome was discussed. PMID:27824909
Laser focus compensating sensing and imaging device
Vann, C.S.
1993-08-31
A laser focus compensating sensing and imaging device permits the focus of a single focal point of different frequency laser beams emanating from the same source point. In particular it allows the focusing of laser beam originating from the same laser device but having differing intensities so that a low intensity beam will not convert to a higher frequency when passing through a conversion crystal associated with the laser generating device. The laser focus compensating sensing and imaging device uses a Cassegrain system to fold the lower frequency, low intensity beam back upon itself so that it will focus at the same focal point as a high intensity beam. An angular tilt compensating lens is mounted about the secondary mirror of the Cassegrain system to assist in alignment. In addition cameras or CCD's are mounted with the primary mirror to sense the focused image. A convex lens is positioned co-axial with the Cassegrain system on the side of the primary mirror distal of the secondary for use in aligning a target with the laser beam. A first alternate embodiment includes a Cassegrain system using a series of shutters and an internally mounted dichroic mirror. A second alternate embodiment uses two laser focus compensating sensing and imaging devices for aligning a moving tool with a work piece.
NASA Astrophysics Data System (ADS)
Zhao, Jiaquan; Li, Renfu; Wu, Haiyan
2018-02-01
In order to characterize the flow structure and the effect of acoustic waves caused by the shock-vortex interaction on the performance of the shock focusing, the incident plane shock wave with a single disturbance vortex focusing in a parabolic cavity is simulated systematically through solving the two-dimensional, unsteady Saint-Venant equations with the two order HLL scheme of Riemann solvers. The simulations show that the dilatation effect to be dominant in the net vorticity generation, while the baroclinic effect is dominate in the absence of initial vortex disturbance. Moreover, the simulations show that the time evolution of maximum focusing pressure with initial vortex is more complicate than that without initial vortex, which has a lot of relevance with the presence of quadrupolar acoustic wave structure induced by shock-vortex interaction and its propagation in the cavity. Among shock and other disturbance parameters, the shock Mach number, vortex Mach number and the shape of parabolic reflector proved to play a critical role in the focusing of shock waves and the strength of viscous dissipation, which in turn govern the evolution of maximum focusing pressure due to the gas dynamic focus, the change in dissipation rate and the coincidence of motion disturbance vortex with aerodynamic focus point.
Wide-field two-photon microscopy with temporal focusing and HiLo background rejection
NASA Astrophysics Data System (ADS)
Yew, Elijah Y. S.; Choi, Heejin; Kim, Daekeun; So, Peter T. C.
2011-03-01
Scanningless depth-resolved microscopy is achieved through spatial-temporal focusing and has been demonstrated previously. The advantage of this method is that a large area may be imaged without scanning resulting in higher throughput of the imaging system. Because it is a widefield technique, the optical sectioning effect is considerably poorer than with conventional spatial focusing two-photon microscopy. Here we propose wide-field two-photon microscopy based on spatio-temporal focusing and employing background rejection based on the HiLo microscope principle. We demonstrate the effects of applying HiLo microscopy to widefield temporally focused two-photon microscopy.
Feelings or Words? Understanding the Content in Self-Report Ratings of Experienced Emotion
Barrett, Lisa Feldman
2005-01-01
People differ in the extent to which their verbal reports of experienced emotion are valence focused or arousal focused. Three multimethod studies are reported to explore whether differential focus reflects individual differences in the cognitive structure of emotion language versus differences in phenomenological experience. Although there was some evidence that valence focus and arousal focus were linked to variations differences in cognitive structure, the findings are also consistent with the view that self-report ratings are being driven by the properties of the feelings that are being reported. Implications for the study of experienced emotion are discussed. PMID:15301632
Use of focused ultrasonication in activity-based profiling of deubiquitinating enzymes in tissue.
Nanduri, Bindu; Shack, Leslie A; Rai, Aswathy N; Epperson, William B; Baumgartner, Wes; Schmidt, Ty B; Edelmann, Mariola J
2016-12-15
To develop a reproducible tissue lysis method that retains enzyme function for activity-based protein profiling, we compared four different methods to obtain protein extracts from bovine lung tissue: focused ultrasonication, standard sonication, mortar & pestle method, and homogenization combined with standard sonication. Focused ultrasonication and mortar & pestle methods were sufficiently effective for activity-based profiling of deubiquitinases in tissue, and focused ultrasonication also had the fastest processing time. We used focused-ultrasonicator for subsequent activity-based proteomic analysis of deubiquitinases to test the compatibility of this method in sample preparation for activity-based chemical proteomics. Copyright © 2016 Elsevier Inc. All rights reserved.
Focusing light through random scattering media by four-element division algorithm
NASA Astrophysics Data System (ADS)
Fang, Longjie; Zhang, Xicheng; Zuo, Haoyi; Pang, Lin
2018-01-01
The focusing of light through random scattering materials using wavefront shaping is studied in detail. We propose a newfangled approach namely four-element division algorithm to improve the average convergence rate and signal-to-noise ratio of focusing. Using 4096 independently controlled segments of light, the intensity at the target is 72 times enhanced over the original intensity at the same position. The four-element division algorithm and existing phase control algorithms of focusing through scattering media are compared by both of the numerical simulation and the experiment. It is found that four-element division algorithm is particularly advantageous to improve the average convergence rate of focusing.
Focusing of intense and divergent ion beams in a magnetic mass analyzer
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jianlin, Ke; Changgeng, Zhou; Rui, Qiu
2014-07-15
A magnetic mass analyzer is used to determine the beam composition of a vacuum arc ion source. In the analyzer, we used the concentric multi-ring electrodes to focus the intense and divergent ion beams. We describe the principle, design, and the test results of the focusing device. The diameter of the beam profile is less than 20 mm when the accelerating voltage is 30 kV and the focusing voltage is about 2.0 kV. The focusing device has been successfully used in the magnetic mass analyzer to separate Ti{sup +}, Ti{sup 2+}, and Ti{sup 3+}.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lin, Zhou; Tu, Juan; Cheng, Jianchun
An acoustic focusing lens incorporated with periodically aligned subwavelength grooves corrugated on its spherical surface has been developed. It is demonstrated theoretically and experimentally that acoustic focusing achieved by using the lens can suppress the relative side-lobe amplitudes, enhance the focal gain, and minimize the shifting of the focus. Use of the lens coupled with a planar ultrasound transducer can generate an ultrasound beam with enhanced acoustic transmission and collimation effect, which offers the capability of improving the safety, efficiency, and accuracy of targeted surgery implemented by high intensity focused ultrasound.
Traverse Focusing of Intense Charged Particle Beams with Chromatic Effects for Heavy Ion Fusion
DOE Office of Scientific and Technical Information (OSTI.GOV)
James M. Mitrani, Igor D. Kaganovich, Ronald C. Davidson
A fi nal focusing scheme designed to minimize chromatic effects is discussed. The Neutralized Drift Compression Experiment-II (NDCX-II) will apply a velocity tilt for longitudinal bunch compression, and a fi nal focusing solenoid (FFS) for transverse bunch compression. In the beam frame, neutralized drift compression causes a suffi ciently large spread in axial momentum, pz , resulting in chromatic effects to the fi nal focal spot during transverse bunch compression. Placing a weaker solenoid upstream of a stronger fi nal focusing solenoid (FFS) mitigates chromatic effects and improves transverse focusing by a factor of approximately 2-4 for appropriate NDCX-II parameters.
Women-focused treatment agencies and process improvement: Strategies to increase client engagement
Wisdom, Jennifer P.; Hoffman, Kim; Rechberger, Elke; Seim, Kay; Owens, Betta
2009-01-01
Behavioral health treatment agencies often struggle to keep clients engaged in treatment. Women clients often have additional factors such as family responsibilities, financial difficulties, or abuse histories that provide extra challenges to remaining in care. As part of a national initiative, four women-focused drug treatment agencies used process improvement to address treatment engagement. Interviews and focus groups with staff assessed the nature and extent of interventions. Women-focused drug treatment agencies selected relational-based interventions to engage clients in treatment and improved four-week treatment retention from 66% to 76%. Process improvement interventions in women-focused treatment may be useful to improve engagement. PMID:20046914
Song, Min-Ho; Choi, Jung-Woo; Kim, Yang-Hann
2012-02-01
A focused source can provide an auditory illusion of a virtual source placed between the loudspeaker array and the listener. When a focused source is generated by time-reversed acoustic focusing solution, its use as a virtual source is limited due to artifacts caused by convergent waves traveling towards the focusing point. This paper proposes an array activation method to reduce the artifacts for a selected listening point inside an array of arbitrary shape. Results show that energy of convergent waves can be reduced up to 60 dB for a large region including the selected listening point. © 2012 Acoustical Society of America
Focusing on ADHD - Attention Deficit Hyperactivity Disorder
... September 2014 Print this issue Focusing on ADHD Attention Deficit Hyperactivity Disorder En español Send us your ... kid. But some kids have such trouble paying attention, staying focused, and finishing tasks that it interferes ...
Zhang, Jiarui; Zhang, Yingjie; Chen, Bo
2017-12-20
The three-dimensional measurement system with a binary defocusing technique is widely applied in diverse fields. The measurement accuracy is mainly determined by out-of-focus projector calibration accuracy. In this paper, a high-precision out-of-focus projector calibration method that is based on distortion correction on the projection plane and nonlinear optimization algorithm is proposed. To this end, the paper experimentally presents the principle that the projector has noticeable distortions outside its focus plane. In terms of this principle, the proposed method uses a high-order radial and tangential lens distortion representation on the projection plane to correct the calibration residuals caused by projection distortion. The final accuracy parameters of out-of-focus projector were obtained using a nonlinear optimization algorithm with good initial values, which were provided by coarsely calibrating the parameters of the out-of-focus projector on the focal and projection planes. Finally, the experimental results demonstrated that the proposed method can accuracy calibrate an out-of-focus projector, regardless of the amount of defocusing.
Extended depth of field integral imaging using multi-focus fusion
NASA Astrophysics Data System (ADS)
Piao, Yongri; Zhang, Miao; Wang, Xiaohui; Li, Peihua
2018-03-01
In this paper, we propose a new method for depth of field extension in integral imaging by realizing the image fusion method on the multi-focus elemental images. In the proposed method, a camera is translated on a 2D grid to take multi-focus elemental images by sweeping the focus plane across the scene. Simply applying an image fusion method on the elemental images holding rich parallax information does not work effectively because registration accuracy of images is the prerequisite for image fusion. To solve this problem an elemental image generalization method is proposed. The aim of this generalization process is to geometrically align the objects in all elemental images so that the correct regions of multi-focus elemental images can be exacted. The all-in focus elemental images are then generated by fusing the generalized elemental images using the block based fusion method. The experimental results demonstrate that the depth of field of synthetic aperture integral imaging system has been extended by realizing the generation method combined with the image fusion on multi-focus elemental images in synthetic aperture integral imaging system.
A focusing reflectarray and its application in microwave virus sanitizer
NASA Astrophysics Data System (ADS)
Hung, Wan-Ting; Tung, Jen-Jung; Chen, Shih-Yuan
2014-10-01
In this paper, a focusing reflectarray based on the conductor-backed strip dipole unit cell is proposed and designed for use in the microwave virus sanitizer. Unlike traditional far-field antennas that form a planar phase front in a specified far-field direction, the focusing reflectarray is designed to coherently add the fields radiated from the feeding antenna at a predetermined focal point, typically within its radiating near-field region and to ensure adequate power density to inactivate the H3N2 virus sample. Furthermore, the focusing reflectarray has a simple and planar structure compared with conventional focusing antennas. Since the microwave resonant absorption frequency of the H3N2 virus is at about 8 GHz, an 8 × 8 focusing reflectarray is designed for operation at 8 GHz. A prototype antenna is then fabricated and used for H3N2 virus sanitization. It is demonstrated experimentally that the death rate of the H3N2 virus sample is up to 93%, verifying the feasibility of the microwave virus sanitizer as well as the proposed focusing reflectarray.
Veselago focusing of anisotropic massless Dirac fermions
NASA Astrophysics Data System (ADS)
Zhang, Shu-Hui; Yang, Wen; Peeters, F. M.
2018-05-01
Massless Dirac fermions (MDFs) emerge as quasiparticles in various novel materials such as graphene and topological insulators, and they exhibit several intriguing properties, of which Veselago focusing is an outstanding example with a lot of possible applications. However, up to now Veselago focusing merely occurred in p-n junction devices based on the isotropic MDF, which lacks the tunability needed for realistic applications. Here, motivated by the emergence of novel Dirac materials, we investigate the propagation behaviors of anisotropic MDFs in such a p-n junction structure. By projecting the Hamiltonian of the anisotropic MDF to that of the isotropic MDF and deriving an exact analytical expression for the propagator, precise Veselago focusing is demonstrated without the need for mirror symmetry of the electron source and its focusing image. We show a tunable focusing position that can be used in a device to probe masked atom-scale defects. This study provides an innovative concept to realize Veselago focusing relevant for potential applications, and it paves the way for the design of novel electron optics devices by exploiting the anisotropic MDF.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Akel, M., E-mail: pscientific2@aec.org.sy; Alsheikh Salo, S.; Ismael, Sh.
2014-07-15
Numerical experiments are systematically carried out using the Lee model code extended to compute the ion beams on various plasma focus devices operated with Deuterium gas. The deuteron beam properties of the plasma focus are studied for low and high energy plasma focus device. The energy spectral distribution for deuteron ions ejected from the pinch plasma is calculated and the ion numbers with energy around 1 MeV is then determined. The deuteron–graphite target interaction is studied for different conditions. The yield of the reaction {sup 12}C(d,n){sup 13}N and the induced radioactivity for one and multi shots plasma focus devices in themore » graphite solid target is investigated. Our results present the optimized high energy repetitive plasma focus devices as an alternative to accelerators for the production of {sup 13}N short lived radioisotopes. However, technical challenges await solutions on two fronts: (a) operation of plasma focus machines at high rep rates for a sufficient period of time (b) design of durable targets that can take the thermal load.« less
Sun, Huey-Min; Li, Shang-Phone; Zhu, Yu-Qian; Hsiao, Bo
2015-09-01
Technological advance in human-computer interaction has attracted increasing research attention, especially in the field of virtual reality (VR). Prior research has focused on examining the effects of VR on various outcomes, for example, learning and health. However, which factors affect the final outcomes? That is, what kind of VR system design will achieve higher usability? This question remains largely. Furthermore, when we look at VR system deployment from a human-computer interaction (HCI) lens, does user's attitude play a role in achieving the final outcome? This study aims to understand the effect of immersion and involvement, as well as users' regulatory focus on usability for a somatosensory VR learning system. This study hypothesized that regulatory focus and presence can effectively enhance user's perceived usability. Survey data from 78 students in Taiwan indicated that promotion focus is positively related to user's perceived efficiency, whereas involvement and promotion focus are positively related to user's perceived effectiveness. Promotion focus also predicts user satisfaction and overall usability perception. Copyright © 2015 Elsevier Ltd and The Ergonomics Society. All rights reserved.
The neurobiology of focus and distraction: The case for incorporating mindfulness into leadership.
Mohapel, Paul
2018-05-01
Increasingly health leaders are experiencing greater demands and pressures, which require the need for better focus while limiting unwarranted distractions. This article offers a neurobiological explanation of how the brain focuses and becomes distracted, in order to help health leaders gain insight into their own effectiveness. Two main neural circuits are contrasted: the mind-wandering default mode circuit and the attentional central executive system. These two systems act in an antagonistic pairing, where the degree of toggling between systems is associated with the degree a person can sustain focus and filter out unwarranted distractions. Excessive multitasking appears to compromise the neural switch of these two systems, thereby diminishing our focus and concentration. In contrast, mindfulness practice is shown to have the opposite effect by enhancing the neural switch, thereby enhancing leadership focus that can lead to greater flexibility, foresight, regulation, and creativity. To conclude, leaders who are excessively distracted, such as with multitasking, may be compromising cognitive brain functioning, while engaging in mindfulness may replenish the brain and thereby enhance leaders' ability to sustain focus and tap into higher cognitive functioning.
Thermoacoustic focusing lens by symmetric Airy beams with phase manipulations
NASA Astrophysics Data System (ADS)
Liu, Chen; Xia, Jian-Ping; Sun, Hong-Xiang; Yuan, Shou-Qi
2017-12-01
We report the realization of broadband acoustic focusing lenses based on two symmetric thermoacoustic phased arrays of Airy beams, in which the units of thermoacoustic phase control are designed by employing air with different temperatures surrounded by rigid insulated boundaries and thermal insulation films. The phase delays of the transmitted and reflected units could cover a whole 2π interval, which arises from the change of the sound velocity of air induced by the variation of the temperature. Based on the units of phase control, we design the transmitted and reflected acoustic focusing lenses with two symmetric Airy beams, and verify the high self-healing focusing characteristic and the feasibility of the thermal insulation films. Besides, the influences of the bending angle of the Airy beam on the focusing performance are discussed in detail. The proposed acoustic lens has advantages of broad bandwidth (about 4.8 kHz), high focusing performance, self-healing feature, and simple structure, which enable it to provide more schemes for acoustic focusing. It has excellent potential applications in acoustic devices.
Compensation of X-ray mirror shape-errors using refractive optics
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sawhney, Kawal, E-mail: Kawal.sawhney@diamond.ac.uk; Laundy, David; Pape, Ian
2016-08-01
Focusing of X-rays to nanometre scale focal spots requires high precision X-ray optics. For nano-focusing mirrors, height errors in the mirror surface retard or advance the X-ray wavefront and after propagation to the focal plane, this distortion of the wavefront causes blurring of the focus resulting in a limit on the spatial resolution. We describe here the implementation of a method for correcting the wavefront that is applied before a focusing mirror using custom-designed refracting structures which locally cancel out the wavefront distortion from the mirror. We demonstrate in measurements on a synchrotron radiation beamline a reduction in the sizemore » of the focal spot of a characterized test mirror by a factor of greater than 10 times. This technique could be used to correct existing synchrotron beamline focusing and nanofocusing optics providing a highly stable wavefront with low distortion for obtaining smaller focus sizes. This method could also correct multilayer or focusing crystal optics allowing larger numerical apertures to be used in order to reduce the diffraction limited focal spot size.« less
WE-G-12A-01: High Intensity Focused Ultrasound Surgery and Therapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Farahani, K; O'Neill, B
More and more emphasis is being made on alternatives to invasive surgery and the use of ionizing radiation to treat various diseases including cancer. Novel screening, diagnosis, treatment and monitoring of response to treatment are also hot areas of research and new clinical technologies. Ultrasound(US) has gained traction in all of the aforementioned areas of focus. Especially with recent advances in the use of ultrasound to noninvasively treat various diseases/organ systems. This session will focus on covering MR-guided focused ultrasound and the state of the art clinical applications, and the second speaker will survey the more cutting edge technologies e.g.more » Focused Ultrasound (FUS) mediated drug delivery, principles of cavitation and US guided FUS. Learning Objectives: Fundamental physics and physical limitations of US interaction with tissue and nanoparticles The alteration of tissue transport using focused ultrasound US control of nanoparticle drug carriers for targeted release The basic principles of MRI-guided focused ultrasound (MRgFUS) surgery and therapy the current state of the art clinical applications of MRgFUS requirements for quality assurance and treatment planning.« less
Perpendicular Diffusion Coefficient of Comic Rays: The Presence of Weak Adiabatic Focusing
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, J. F.; Ma, Q. M.; Song, T.
The influence of adiabatic focusing on particle diffusion is an important topic in astrophysics and plasma physics. In the past, several authors have explored the influence of along-field adiabatic focusing on the parallel diffusion of charged energetic particles. In this paper, using the unified nonlinear transport theory developed by Shalchi and the method of He and Schlickeiser, we derive a new nonlinear perpendicular diffusion coefficient for a non-uniform background magnetic field. This formula demonstrates that the particle perpendicular diffusion coefficient is modified by along-field adiabatic focusing. For isotropic pitch-angle scattering and the weak adiabatic focusing limit, the derived perpendicular diffusionmore » coefficient is independent of the sign of adiabatic focusing characteristic length. For the two-component model, we simplify the perpendicular diffusion coefficient up to the second order of the power series of the adiabatic focusing characteristic quantity. We find that the first-order modifying factor is equal to zero and that the sign of the second order is determined by the energy of the particles.« less
A case study investigation of practices and beliefs of teachers at a STEM-focused elementary school
NASA Astrophysics Data System (ADS)
Martin, Billy J.
Proponents of STEM education have highlighted the need for increasing STEM skills among students. To address this need, there have been recommendations to create new STEM-focused schools, a majority of which are to be STEM-focused elementary and middle schools. However, STEM school research remains focused on outcomes at the secondary and postsecondary level, with little attention being given to knowing more about the role that elementary education plays in STEM outcomes. Case study design was used to investigate teachers at one STEM-focused elementary school to identify the practices and beliefs reported as important in STEM teaching and learning. Using survey and in-depth interviews, it was found that designation as a STEM-focused school promotes the use of more inquiry-oriented teaching practices and facilitates the use of strategies for developing confidence and competence in STEM among staff and students. The information uncovered in this study could provide leaders of any organization desiring to become a STEM-focused institution information about specific beliefs and practices that have the greatest potential to support changes in teaching.
NASA Astrophysics Data System (ADS)
Liu, Yan; Lai, Puxiang; Ma, Cheng; Xu, Xiao; Suzuki, Yuta; Grabar, Alexander A.; Wang, Lihong V.
2014-03-01
Time-reversed ultrasonically encoded (TRUE) optical focusing is an emerging technique that focuses light deep into scattering media by phase-conjugating ultrasonically encoded diffuse light. In previous work, the speed of TRUE focusing was limited to no faster than 1 Hz by the response time of the photorefractive phase conjugate mirror, or the data acquisition and streaming speed of the digital camera; photorefractive-crystal-based TRUE focusing was also limited to the visible spectral range. These time-consuming schemes prevent this technique from being applied in vivo, since living biological tissue has a speckle decorrelation time on the order of a millisecond. In this work, using a Tedoped Sn2P2S6 photorefractive crystal at a near-infrared wavelength of 793 nm, we achieved TRUE focusing inside dynamic scattering media having a speckle decorrelation time as short as 7.7 ms. As the achieved speed approaches the tissue decorrelation rate, this work is an important step forward toward in vivo applications of TRUE focusing in deep tissue imaging, photodynamic therapy, and optical manipulation.
A focused approach to safety guidebook.
DOT National Transportation Integrated Search
2011-08-23
"The Federal Highway Administration (FHWA) has developed the Focused Approach to Safety in order to better address the most critical safety challenges by devoting additional attention to high priority States. The purpose of the Focused Approach is to...
Helping the Warfighter Become Green! (Briefing Charts)
2011-02-01
CHAIN LEADERSHIPARFIGHTER-FOCUSED, GLOBALLY RESPONSIVE, FISCALLY RESPONSIBLE SUPPLY CHAIN LEADERSHIP DOD EMALL DOD’s Online Shopping Tool • Web self...LEADERSHIP DOD EMALL DOD’s Online Shopping Tool WARFIGHTER FOCUSED, GLOBALLY RESPONSIVE SUPPLY CHAIN LEADERSHIPARFIGHTER FOCUSED, GLOBALLY RESPONSIVE
Electrowetting-based liquid lenses for endoscopy
NASA Astrophysics Data System (ADS)
Kuiper, S.
2011-03-01
In endoscopy there is a need for cameras with adjustable focus. In flexible and capsule endoscopes conventional focus systems are not suitable, because of restrictions in diameter and lens displacement range. In this paper it is shown that electrowetting-based variable-focus liquid lenses can provide a solution. A theoretical comparison is made between displacing and deforming lenses, and a demonstrator was built to prove the optical feasibility of focusing with liquid lenses in endoscopes.
Needs of Non-Energy Focused Contractors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liakus, C.
2012-12-01
To better understand the informational needs of non-energy focused contractors, including what information they need to motivate them to become energy-focused, the BARA team studied the type of information provided by the national programs, trade associations, and manufacturers that were researched for the related technical report: Effective Communication of Energy Efficiency. While that report focused on the delivery method, format, and strategy of the information, this study examines the content being put forward.
Needs of Non Energy-Focused Contractors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liaukus, C.
2012-12-01
To better understand the informational needs of non energy-focused contractors, including what information they need to motivate them to become energy-focused, the BARA team studied the type of information provided by the national programs, trade associations, and manufacturers that were researched for the related technical report: Effective Communication of Energy Efficiency. While that report focused on the delivery method, format, and strategy of the information, this study examines the content being put forward.
Note: Automated optical focusing on encapsulated devices for scanning light stimulation systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bitzer, L. A.; Benson, N., E-mail: niels.benson@uni-due.de; Schmechel, R.
Recently, a scanning light stimulation system with an automated, adaptive focus correction during the measurement was introduced. Here, its application on encapsulated devices is discussed. This includes the changes an encapsulating optical medium introduces to the focusing process as well as to the subsequent light stimulation measurement. Further, the focusing method is modified to compensate for the influence of refraction and to maintain a minimum beam diameter on the sample surface.
Designing Interactive Multimedia Instruction to Address Soldiers’ Learning Needs
2014-12-01
A point of need design seeks to identify and meet specific learning needs. It does so by focusing on the learning needs of an identified group ...instructional design and tailored training techniques to address the Army Learning Model (ALM) point of need concept. The point of need concept focuses both on ...developing six IMI exemplars focused on point of need training, including three variations of needs-focused designs : familiarization, core, and tailored
NASA Astrophysics Data System (ADS)
Reece, Amy E.
The microfabrication of microfluidic control systems and advances in molecular amplification tools has enabled the miniaturization of single cell analytical platforms for the efficient, highly selective enumeration and molecular characterization of rare and diseased cells from clinical samples. In many cases, the high-throughput nature of microfluidic inertial focusing has enabled the popularization of this new class of Lab-on-a-Chip devices that exhibit numerous advantages over conventional methods as prognostic and diagnostic tools. Inertial focusing is the passive, sheathless alignment of particles and cells to precise spatiotemporal equilibrium positions that arise from a force balance between opposing inertial lift forces and hydrodynamic repulsions. The applicability of inertial focusing to a spectrum of filtration, separation and encapsulation challenges places heavy emphasis upon the accurate description of the hydrodynamic forces responsible for predictable inertial focusing behavior. These inertial focusing fundamentals, limitations and their applications are studied extensively throughout this work.
An Atomic Lens Using a Focusing Hollow Beam
NASA Astrophysics Data System (ADS)
Xia, Yong; Yin, Jian-Ping; Wang, Yu-Zhu
2003-05-01
We propose a new method to generate a focused hollow laser beam by using an azimuthally distributed 2pi-phase plate and a convergent thin lens, and calculate the intensity distribution of the focused hollow beam in free propagation space. The relationship between the waist wo of the incident collimated Gaussian beam and the dark spot size of the focused hollow beam at the focal point, and the relationship between the focal length f of the thin lens and the dark spot size are studied respectively. The optical potential of the blue-detuned focused hollow beam for 85Rb atoms is calculated. Our study shows that when the larger waist w of the incident Gaussian beam and the shorter focal length f of the lens are chosen, we can obtain an extremely small dark spot size of the focused hollow beam, which can be used to form an atomic lens with a resolution of several angstroms.
Methodological Aspects of Focus Groups in Health Research
Tausch, Anja P.; Menold, Natalja
2016-01-01
Although focus groups are commonly used in health research to explore the perspectives of patients or health care professionals, few studies consider methodological aspects in this specific context. For this reason, we interviewed nine researchers who had conducted focus groups in the context of a project devoted to the development of an electronic personal health record. We performed qualitative content analysis on the interview data relating to recruitment, communication between the focus group participants, and appraisal of the focus group method. The interview data revealed aspects of the focus group method that are particularly relevant for health research and that should be considered in that context. They include, for example, the preferability of face-to-face recruitment, the necessity to allow participants in patient groups sufficient time to introduce themselves, and the use of methods such as participant-generated cards and prioritization. PMID:28462326
Probst, Tahira M.; Jiang, Lixin
2016-01-01
The purpose of the current study was to assess real-time physiological reactions to the threat of layoffs and to determine whether the use of an emotion-focused vs. problem-focused coping intervention would be more efficacious in attenuating these physiological reactions. A 2 (coping intervention) × 4 (within-subjects time points) mixed experimental design was used to test the hypotheses. Eighty-four undergraduates participated in this laboratory experiment during which their galvanic skin response (GSR) and heart rate (HR) were continuously monitored. Analyses indicate that individuals instructed to utilize an emotion-focused coping strategy experienced a significantly greater decline in their GSR compared to those utilizing the problem-focused coping method. Results suggest organizations conducting layoffs might focus first on dealing with the emotional aftermath of downsizing before focusing on problem-solving tasks, such as resume writing and other traditional outplacement activities. PMID:26999186
Ball, Samuel A.; Maccarelli, Lisa M.; LaPaglia, Donna M.; Ostrowski, Mark J.
2011-01-01
We conducted a randomized comparison of Dual Focus Schema Therapy with Individual Drug Counseling as enhancements to residential treatment for 105 substance dependent patients with versus without specific personality disorders. Both therapies were manual-guided and delivered for 6 months by experienced psychotherapists intensively trained and supervised with independent fidelity assessment. Using Cox Proportional Hazards, we found no psychotherapy differences in retention (days in treatment). Hierarchical Linear Modeling indicated that personality disordered participants started with higher psychiatric, interpersonal, and dysphoria symptoms, and both therapies reduced symptoms over 6 months. Contrary to predictions, Individual Drug Counseling resulted in more sustained reductions than Dual Focus Schema Therapy in several symptoms for several personality disorders. Our findings raised important questions about the added value of integrative or dual-focus therapies for co-occurring personality disorders and substance dependence relative to empirically supported therapies focused more specifically on addiction symptoms. PMID:21543951
Modelling of influence of spherical aberration coefficients on depth of focus of optical systems
NASA Astrophysics Data System (ADS)
Pokorný, Petr; Šmejkal, Filip; Kulmon, Pavel; Mikš, Antonín.; Novák, Jiří; Novák, Pavel
2017-06-01
This contribution describes how to model the influence of spherical aberration coefficients on the depth of focus of optical systems. Analytical formulas for the calculation of beam's caustics are presented. The conditions for aberration coefficients are derived for two cases when we require that either the Strehl definition or the gyration radius should be the identical in two symmetrically placed planes with respect to the paraxial image plane. One can calculate the maximum depth of focus and the minimum diameter of the circle of confusion of the optical system corresponding to chosen conditions. This contribution helps to understand how spherical aberration may affect the depth of focus and how to design such an optical system with the required depth of focus. One can perform computer modelling and design of the optical system and its spherical aberration in order to achieve the required depth of focus.
Optical fiber plasmonic lens for near-field focusing fabricated through focused ion beam
NASA Astrophysics Data System (ADS)
Sloyan, Karen; Melkonyan, Henrik; Moreira, Paulo; Dahlem, Marcus S.
2017-02-01
We report on numerical simulations and fabrication of an optical fiber plasmonic lens for near-field focusing applications. The plasmonic lens consists of an Archimedean spiral structure etched through a 100 nm-thick Au layer on the tip of a single-mode SM600 optical fiber operating at a wavelength of 632:8 nm. Three-dimensional finite-difference time-domain computations show that the relative electric field intensity of the focused spot increases 2:1 times when the number of turns increases from 2 to 12. Furthermore, a reduction of the intensity is observed when the initial inner radius is increased. The optimized plasmonic lens focuses light into a spot with a full-width at half-maximum of 182 nm, beyond the diffraction limit. The lens was fabricated by focused ion beam milling, with a 200nm slit width.
Spatiotemporal control of laser intensity
NASA Astrophysics Data System (ADS)
Froula, Dustin H.; Turnbull, David; Davies, Andrew S.; Kessler, Terrance J.; Haberberger, Dan; Palastro, John P.; Bahk, Seung-Whan; Begishev, Ildar A.; Boni, Robert; Bucht, Sara; Katz, Joseph; Shaw, Jessica L.
2018-05-01
The controlled coupling of a laser to plasma has the potential to address grand scientific challenges1-6, but many applications have limited flexibility and poor control over the laser focal volume. Here, we present an advanced focusing scheme called a `flying focus', where a chromatic focusing system combined with chirped laser pulses enables a small-diameter laser focus to propagate nearly 100 times its Rayleigh length. Furthermore, the speed at which the focus moves (and hence the peak intensity) is decoupled from the group velocity of the laser. It can co- or counter-propagate along the laser axis at any velocity. Experiments validating the concept measured subluminal (-0.09c) to superluminal (39c) focal-spot velocities, generating a nearly constant peak intensity over 4.5 mm. Among possible applications, the flying focus could be applied to a photon accelerator7 to mitigate dephasing, facilitating the production of tunable XUV sources.
The multifocus plenoptic camera
NASA Astrophysics Data System (ADS)
Georgiev, Todor; Lumsdaine, Andrew
2012-01-01
The focused plenoptic camera is based on the Lippmann sensor: an array of microlenses focused on the pixels of a conventional image sensor. This device samples the radiance, or plenoptic function, as an array of cameras with large depth of field, focused at a certain plane in front of the microlenses. For the purpose of digital refocusing (which is one of the important applications) the depth of field needs to be large, but there are fundamental optical limitations to this. The solution of the above problem is to use and array of interleaved microlenses of different focal lengths, focused at two or more different planes. In this way a focused image can be constructed at any depth of focus, and a really wide range of digital refocusing can be achieved. This paper presents our theory and results of implementing such camera. Real world images are demonstrating the extended capabilities, and limitations are discussed.
Optimal focusing conditions of lenses using Gaussian beams
Franco, Juan Manuel; Cywiak, Moisés; Cywiak, David; ...
2016-04-02
By using the analytical equations of the propagation of Gaussian beams in which truncation exhibits negligible consequences, we describe a method that uses the value of the focal length of a focusing lens to classify its focusing performance. In this study, we show that for different distances between a laser and a focusing lens there are different planes where best focusing conditions can be obtained and we demonstrate how the value of the focal length impacts the lens focusing properties. To perform the classification we introduce the term delimiting focal length. As the value of the focal length used inmore » wave propagation theory is nominal and difficult to measure accurately, we describe an experimental approach to calculate its value matching our analytical description. Finally, we describe possible applications of the results for characterizing Gaussian sources, for measuring focal lengths and/or alternatively for characterizing piston-like movements.« less
Development of TPF-1 plasma focus for education
NASA Astrophysics Data System (ADS)
Picha, R.; Promping, J.; Channuie, J.; Poolyarat, N.; Sangaroon, S.; Traikool, T.
2017-09-01
The plasma focus is a device that uses high voltage and electromagnetic force to induce plasma generation and acceleration, in order to cause nuclear reactions. Radiation of various types (X-ray, gamma ray, electrons, ions, neutrons) can be generated using this method during the pinch phase, thus making the plasma focus able to serve as a radiation source. Material testing, modification, and identification are among the current applications of the plasma focus. Other than being an alternative option to isotopic sources, the plasma focus, which requires multidisciplinary team of personnel to design, operate, and troubleshoot, can also serve as an excellent learning device for physics and engineering students in the fields including, but not limited to, plasma physics, nuclear physics, electronics engineering, and mechanical engineering. This work describes the parameters and current status of Thai Plasma Focus 1 (TPF-1) and the characteristics of the plasma being produced in the machine using a Rogowski coil.
Using focus groups to develop a culturally sensitive videotape intervention for HIV-positive women.
Murdaugh, C; Russell, R B; Sowell, R
2000-12-01
Research-based interventions for women with the human immunodeficiency virus (HIV) are usually developed without input from the women who receive the intervention. An exploratory study was performed using focus group methodology to develop a culturally sensitive videotape intervention for educating HIV-positive women about pregnancy and antiretroviral use. Women who met the study criteria were HIV-positive and of childbearing age. These women volunteered to participate in the focus groups to provide information on decisions concerning pregnancy and antiretroviral use during pregnancy to decrease perinatal transmission. A total of five focus groups were conducted in 1998. Responses to three questions that were relevant to the video are presented in this article. Information gained from the focus groups was used successfully to develop a videotape currently being used in a multisite intervention study. Focus group methodology is a useful strategy to develop culturally and content relevant educational interventions for research and practice.
Sarvazyan, A; Fillinger, L
2009-03-01
The ability to generate short focused ultrasonic pulses with duration on the order of one period of carrier frequency depends on the bandwidth of the transmitter as the pulse duration is inversely proportional to the bandwidth. Conventional focusing arrays used for focusing ultrasound have limited bandwidth due to the resonant nature of the piezoelements generating ultrasound. Theoretically it is possible to build a broadband phased array composed of "non-resonant" elements: wedge-shaped or flat-concave piezotransducers, though there are numerous technical difficulties in designing arrays with hundreds of elements of complex shape. This task is much easier to realize in an alternative technique of ultrasound focusing based on the principles of Time Reversed Acoustics (TRA) because in TRA systems, effective focusing can be achieved with just a few, or even one, transducers. The goal of this study is to demonstrate the possibility of broadband focusing of ultrasonic waves using a TRA system with non-resonant transducers and to explore the factors affecting the performance of such a system. A new type of TRA reverberators, such as water-filled thin-wall plastic vessels, which can be used with the submersible piezotransducers fixed internally in the reverberator, are proposed and tested. The experiments are conducted in a water tank with the walls and bottom covered by a sound absorbing lining. A needle hydrophone mounted on a 3D positioning system is used as a beacon for the TRA focusing and then for measuring the spatial distribution of the focused ultrasound field. The bandwidth and spatial distribution of the signal focused by the TRA system using a single channel with the resonant versus non-resonant transducers have been analyzed. Two types of non-resonant transducers were tested: a flat-concave transducer with a diameter of 30 mm, and a thickness varying from 2 mm in the center to 11 mm at the edge, and a specially designed submersible transducer having an uneven shape with a diameter of about 25 mm and a thickness varying from 2 to 6 mm. It was shown that TRA focusing system using non-resonant transducer had a bandwidth at 10 dB of 500 kHz while the resonant transducer provided about 100 kHz bandwidth. Correspondingly, the extended bandwidth of the TRA focusing system, especially toward higher frequencies, provides a 50% sharper spatial distribution. Furthermore, the relative level of the background ultrasound was reduced by a factor up to 3 as more frequencies were added coherently in focus and incoherently out of focus. Advantages of water-filled reverberators made of thin-wall plastic vessels include easy manufacturing, low costs, extreme simplicity, and good acoustical matching with soft tissues, important for biomedical applications.
NASA Astrophysics Data System (ADS)
Loveley, Matthew R.; Marcantonio, Franco; Lyle, Mitchell; Ibrahim, Rami; Hertzberg, Jennifer E.; Schmidt, Matthew W.
2017-12-01
Here, we examine how redistribution of differing grain sizes by sediment focusing processes in Panama Basin sediments affects the use of 230Th as a constant-flux proxy. We study representative sediments of Holocene and Last Glacial Maximum (LGM) time slices from four sediment cores from two different localities close to the ridges that bound the Panama Basin. Each locality contains paired sites that are seismically interpreted to have undergone extremes in sediment redistribution, i.e., focused versus winnowed sites. Both Holocene and LGM samples from sites where winnowing has occurred contain significant amounts (up to 50%) of the 230Th within the >63 μm grain size fraction, which makes up 40-70% of the bulk sediment analyzed. For sites where focusing has occurred, Holocene and LGM samples contain the greatest amounts of 230Th (up to 49%) in the finest grain-sized fraction (<4 μm), which makes up 26-40% of the bulk sediment analyzed. There are slight underestimations of 230Th-derived mass accumulation rates (MARs) and overestimations of 230Th-derived focusing factors at focused sites, while the opposite is true for winnowed sites. Corrections made using a model by Kretschmer et al. (2010) suggest a maximum change of about 30% in 230Th-derived MARs and focusing factors at focused sites, except for our most focused site which requires an approximate 70% correction in one sample. Our 230Th-corrected 232Th flux results suggest that the boundary between hemipelagically- and pelagically-derived sediments falls between 350 and 600 km from the continental margin.
Kagawa-Singer, Marjorie; Adler, Shelley R; Mouton, Charles E; Ory, Marcia; Underwood, Lynne G
2009-01-01
To outline the lessons learned about the use of focus groups for the multisite, multi-ethnic longitudinal Study of Women Across the Nation (SWAN). Focus groups were designed to identify potential cultural differences in the incidence of symptoms and the meaning of transmenopause among women of diverse cultures, and to identify effective recruitment and retention strategies. Inductive and deductive focus groups for a multi-ethnic study. Seven community research sites across the United States conducted focus groups with six ethnic populations: African American, Chinese American, Japanese American, Mexican American, non-Hispanic white, and Puerto Rican. Community women from each ethnic group of color. A set of four/five focus groups in each ethnic group as the formative stage of the deductive, quantitative SWAN survey. Identification of methodological advantages and challenges to the successful implementation of formative focus groups in a multi-ethnic, multi-site population-based epidemiologic study. We provide recommendations from our lessons learned to improve the use of focus groups in future studies with multi-ethnic populations. Mixed methods using inductive and deductive approaches require the scientific integrity of both research paradigms. Adequate resources and time must be budgeted as essential parts of the overall strategy from the outset of study. Inductive cross-cultural researchers should be key team members, beginning with inception through each subsequent design phase to increase the scientific validity, generalizability, and comparability of the results across diverse ethnic groups, to assure the relevance, validity and applicability of the findings to the multicultural population of focus.
Petrie Thomas, Julianne H.; Whitfield, Michael F.; Oberlander, Tim F.; Synnes, Anne R.; Grunau, Ruth E.
2012-01-01
The majority of children who are born very preterm escape major impairment, yet more subtle cognitive and attention problems are very common in this population. Previous research has linked infant focused attention during exploratory play to later cognition in children born full-term and preterm. Infant focused attention can be indexed by sustained decreases in heart rate (HR). However there are no preterm studies that have jointly examined infant behavioral attention and concurrent HR response during exploratory play in relation to developing cognition. We recruited preterm infants free from neonatal conditions associated with major adverse outcomes, and further excluded infants with developmental delay (Bayley Mental Development Index [MDI < 70]) at 8 months corrected age (CA). During infant exploratory play at 8 months CA, focused attention and concurrent HR response were compared in 83 preterm infants (born 23–32 weeks gestational age [GA]) who escaped major impairment to 46 full-term infants. Focused attention and HR response were then examined in relation to Bayley MDI, after adjusting for neonatal risk. MDI did not differ by group, yet full-term infants displayed higher global focused attention ratings. Among the extremely preterm infants born <29 weeks, fewer days on mechanical ventilation, mean longest focus, and greater HR deceleration during focused attention episodes, accounted for 49% of adjusted variance in predicting concurrent MDI. There were no significant associations for later-born gestational age (29–32 weeks) or full-term infants. Among extremely preterm infants who escape major impairment, our findings suggest unique relationships between focused attention, HR deceleration, and developing cognition. PMID:22487941
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lewellen, J. W.; Noonan, J.; Accelerator Systems Division
2005-01-01
Conventional {pi}-mode rf photoinjectors typically use magnetic solenoids for emittance compensation. This provides independent focusing strength but can complicate rf power feed placement, introduce asymmetries (due to coil crossovers), and greatly increase the cost of the photoinjector. Cathode-region focusing can also provide for a form of emittance compensation. Typically this method strongly couples focusing strength to the field gradient on the cathode, however, and usually requires altering the longitudinal position of the cathode to change the focusing. We propose a new method for achieving cathode-region variable-strength focusing for emittance compensation. The new method reduces the coupling to the gradient onmore » the cathode and does not require a change in the longitudinal position of the cathode. Expected performance for an S-band system is similar to conventional solenoid-based designs. This paper presents the results of rf cavity and beam dynamics simulations of the new design. We have proposed a method for performing emittance compensation using a cathode-region focusing scheme. This technique allows the focusing strength to be adjusted somewhat independently of the on-axis field strength. Beam dynamics calculations indicate performance should be comparable to presently in-use emittance compensation schemes, with a simpler configuration and fewer possibilities for emittance degradation due to the focusing optics. There are several potential difficulties with this approach, including cathode material selection, cathode heating, and peak fields in the gun. We hope to begin experimenting with a cathode of this type in the near future, and several possibilities exist for reducing the peak gradients to more acceptable levels.« less
Design of voice coil motor dynamic focusing unit for a laser scanner
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee, Moon G.; Kim, Gaeun; Lee, Chan-Woo
2014-04-15
Laser scanning systems have been used for material processing tasks such as welding, cutting, marking, and drilling. However, applications have been limited by the small range of motion and slow speed of the focusing unit, which carries the focusing optics. To overcome these limitations, a dynamic focusing system with a long travel range and high speed is needed. In this study, a dynamic focusing unit for a laser scanning system with a voice coil motor (VCM) mechanism is proposed to enable fast speed and a wide focusing range. The VCM has finer precision and higher speed than conventional step motorsmore » and a longer travel range than earlier lead zirconium titanate actuators. The system has a hollow configuration to provide a laser beam path. This also makes it compact and transmission-free and gives it low inertia. The VCM's magnetics are modeled using a permeance model. Its design parameters are determined by optimization using the Broyden–Fletcher–Goldfarb–Shanno method and a sequential quadratic programming algorithm. After the VCM is designed, the dynamic focusing unit is fabricated and assembled. The permeance model is verified by a magnetic finite element method simulation tool, Maxwell 2D and 3D, and by measurement data from a gauss meter. The performance is verified experimentally. The results show a resolution of 0.2 μm and travel range of 16 mm. These are better than those of conventional focusing systems; therefore, this focusing unit can be applied to laser scanning systems for good machining capability.« less
Evidence Base Update for Autism Spectrum Disorder.
Smith, Tristram; Iadarola, Suzannah
2015-01-01
This evidence base update examines the level of empirical support for interventions for children with autism spectrum disorder (ASD) younger than 5 years old. It focuses on research published since a previous review in this journal (Rogers & Vismara, 2008 ). We identified psychological or behavioral interventions that had been manualized and evaluated in either (a) experimental or quasi-experimental group studies or (b) systematic reviews of single-subject studies. We extracted data from all studies that met these criteria and were published after the previous review. Interventions were categorized across two dimensions. First, primary theoretical principles included applied behavior analysis (ABA), developmental social-pragmatic (DSP), or both. Second, practice elements included scope (comprehensive or focused), modality (individual intervention with the child, parent training, or classrooms), and intervention targets (e.g., spoken language or alternative and augmentative communication). We classified two interventions as well-established (individual, comprehensive ABA and teacher-implemented, focused ABA + DSP), 3 as probably efficacious (individual, focused ABA for augmentative and alternative communication; individual, focused ABA + DSP; and focused DSP parent training), and 5 as possibly efficacious (individual, comprehensive ABA + DSP; comprehensive ABA classrooms; focused ABA for spoken communication; focused ABA parent training; and teacher-implemented, focused DSP). The evidence base for ASD interventions has grown substantially since 2008. An increasing number of interventions have some empirical support; others are emerging as potentially efficacious. Priorities for future research include improving outcome measures, developing interventions for understudied ASD symptoms (e.g., repetitive behaviors), pinpointing mechanisms of action in interventions, and adapting interventions for implementation with fidelity by community providers.
Alsallaq, Ramzi A; Buttolph, Jasmine; Cleland, Charles M; Hallett, Timothy; Inwani, Irene; Agot, Kawango; Kurth, Ann E
2017-01-01
We compared the impact and costs of HIV prevention strategies focusing on youth (15-24 year-old persons) versus on adults (15+ year-old persons), in a high-HIV burden context of a large generalized epidemic. Compartmental age-structured mathematical model of HIV transmission in Nyanza, Kenya. The interventions focused on youth were high coverage HIV testing (80% of youth), treatment at diagnosis (TasP, i.e., immediate start of antiretroviral therapy [ART]) and 10% increased condom usage for HIV-positive diagnosed youth, male circumcision for HIV-negative young men, pre-exposure prophylaxis (PrEP) for high-risk HIV-negative females (ages 20-24 years), and cash transfer for in-school HIV-negative girls (ages 15-19 years). Permutations of these were compared to adult-focused HIV testing coverage with condoms and TasP. The youth-focused strategy with ART treatment at diagnosis and condom use without adding interventions for HIV-negative youth performed better than the adult-focused strategy with adult testing reaching 50-60% coverage and TasP/condoms. Over the long term, the youth-focused strategy approached the performance of 70% adult testing and TasP/condoms. When high coverage male circumcision also is added to the youth-focused strategy, the combined intervention outperformed the adult-focused strategy with 70% testing, for at least 35 years by averting 94,000 more infections, averting 5.0 million more disability-adjusted life years (DALYs), and saving US$46.0 million over this period. The addition of prevention interventions beyond circumcision to the youth-focused strategy would be more beneficial if HIV care costs are high, or when program delivery costs are relatively high for programs encompassing HIV testing coverage exceeding 70%, TasP and condoms to HIV-infected adults compared to combination prevention programs among youth. For at least the next three decades, focusing in high burden settings on high coverage HIV testing, ART treatment upon diagnosis, condoms and male circumcision among youth may outperform adult-focused ART treatment upon diagnosis programs, unless the adult testing coverage in these programs reaches very high levels (>70% of all adults reached) at similar program costs. Our results indicate the potential importance of age-targeting for HIV prevention in the current era of 'test and start, ending AIDS' goals to ameliorate the HIV epidemic globally.
NASA Astrophysics Data System (ADS)
Yu, Li-Li; Shou, Wen-De; Hui, Chun
2012-02-01
A theoretical model of focused acoustic field for a multi-annular phased array on concave spherical surface is proposed. In this model, the source boundary conditions of the spheroidal beam equation (SBE) for multi-annular phased elements are studied. Acoustic field calculated by the dynamic focusing model of SBE is compared with numerical results of the O'Neil and Khokhlov—Zabolotskaya—Kuznetsov (KZK) model, respectively. Axial dynamic focusing and the harmonic effects are presented. The results demonstrate that the dynamic focusing model of SBE is good valid for a concave multi-annular phased array with a large aperture angle in the linear or nonlinear field.
Self-focus, other-focus, and interpersonal needs as correlates of loneliness.
Green, V A; Wildermuth, N L
1993-12-01
Residential college students (44 men, 51 women) participated in a questionnaire study to clarify the relationship between loneliness, self- or other-focus, and interpersonal needs. Contrary to predictions, loneliness was unrelated to self-focus, other-focus, or the ability to elicit disclosure from others. However, sex differences were found on interpersonal needs. Specifically, loneliness in men was predicted by a lack of expressed inclusion and a desire for control from others, while loneliness in women was predicted by a lack of expressed affection. These findings suggest that lonely men and women may benefit from different intervention strategies. Outcome studies are needed to ensure that such interventions actually reduce loneliness.
Concentric circular focusing reflector realized using high index contrast gratings
NASA Astrophysics Data System (ADS)
Fang, Wenjing; Huang, Yongqing; Fei, Jiarui; Duan, Xiaofeng; Liu, Kai; Ren, Xiaomin
2017-11-01
A non-periodic concentric circular high index contrast grating (CC-HCG) focusing reflector on 500 nm silicon-on-insulator (SOI) platform is fabricated and experimentally demonstrated. The proposed mirror is realized with phase modulation of wave front in a high reflectivity region. The circular structure based HCG focusing reflector has a spot of high concentration at the 10.87 mm with normal incidence for radially polarization, along with the center wavelength set at 1550 nm. The FWHM spot size of the focusing beam decreases to 260 μm, and the intensity increases to 1.26 compared with the incident beam. The focusing efficiency of about 80% is observed at 1550 nm in the experimental measurement.
Settoon, Randall P; Mossholder, Kevin W
2002-04-01
A model hypothesizing relationship quality and relationship context as antecedents of two complementary forms of interpersonal citizenship behavior (ICB) was tested. Measures with coworkers as the frame of reference were used to collect data from 273 individuals working in 2 service-oriented organizations. As hypothesized, variables reflecting relationship quality were associated with person-focused ICB, as mediated by empathic concern. Also as hypothesized, a relationship context variable, network centrality, exhibited a direct relationship with task-focused ICB. Unexpectedly, network centrality was directly associated with person-focused ICB. and empathic concern was associated with task-focused ICB. The results are discussed, and implications for research and practice are offered.
Lee, Dong-Gwi; Park, Jae Joon; Bae, Byeong Hoon; Lim, Hyun-Woo
2018-04-03
The present study investigated the moderating effects of prevention-focus on the paths from the dimensions of insecure attachment (attachment avoidance and attachment anxiety) to depression. Two hundred twenty eight Korean college students completed the Experience in Close Relationship - Revised Scale; the Regulatory Focus Strategies Scale; and the Center for Epidemiologic Studies Depression Scale. Results revealed a significant moderating effect for prevention-focus on the path from attachment avoidance to depression, but not on the path from attachment anxiety to depression. They further suggest that different interventions are needed for different combinations of persons' insecure attachment dimensions and levels of prevention-focus. Counseling implications and suggestions for future research are discussed.
Pressure-flow reducer for aerosol focusing devices
Gard, Eric; Riot, Vincent; Coffee, Keith; Woods, Bruce; Tobias, Herbert; Birch, Jim; Weisgraber, Todd
2008-04-22
A pressure-flow reducer, and an aerosol focusing system incorporating such a pressure-flow reducer, for performing high-flow, atmosphere-pressure sampling while delivering a tightly focused particle beam in vacuum via an aerodynamic focusing lens stack. The pressure-flow reducer has an inlet nozzle for adjusting the sampling flow rate, a pressure-flow reduction region with a skimmer and pumping ports for reducing the pressure and flow to enable interfacing with low pressure, low flow aerosol focusing devices, and a relaxation chamber for slowing or stopping aerosol particles. In this manner, the pressure-flow reducer decouples pressure from flow, and enables aerosol sampling at atmospheric pressure and at rates greater than 1 liter per minute.
Cooks, Robert Graham; Baird, Zane; Peng, Wen-Ping
2015-11-10
The invention generally relates to apparatuses for focusing ions at or above ambient pressure and methods of use thereof. In certain embodiments, the invention provides an apparatus for focusing ions that includes an electrode having a cavity, at least one inlet within the electrode configured to operatively couple with an ionization source, such that discharge generated by the ionization source is injected into the cavity of the electrode, and an outlet. The cavity in the electrode is shaped such that upon application of voltage to the electrode, ions within the cavity are focused and directed to the outlet, which is positioned such that a proximal end of the outlet receives the focused ions and a distal end of the outlet is open to ambient pressure.
Cooks, Robert Graham; Baird, Zane; Peng, Wen-Ping
2017-01-17
The invention generally relates to apparatuses for focusing ions at or above ambient pressure and methods of use thereof. In certain embodiments, the invention provides an apparatus for focusing ions that includes an electrode having a cavity, at least one inlet within the electrode configured to operatively couple with an ionization source, such that discharge generated by the ionization source is injected into the cavity of the electrode, and an outlet. The cavity in the electrode is shaped such that upon application of voltage to the electrode, ions within the cavity are focused and directed to the outlet, which is positioned such that a proximal end of the outlet receives the focused ions and a distal end of the outlet is open to ambient pressure.
Merrill, Frank E.; Morris, Christopher
2005-05-17
A system capable of performing radiography using a beam of electrons. Diffuser means receive a beam of electrons and diffuse the electrons before they enter first matching quadrupoles where the diffused electrons are focused prior to the diffused electrons entering an object. First imaging quadrupoles receive the focused diffused electrons after the focused diffused electrons have been scattered by the object for focusing the scattered electrons. Collimator means receive the scattered electrons and remove scattered electrons that have scattered to large angles. Second imaging quadrupoles receive the collimated scattered electrons and refocus the collimated scattered electrons and map the focused collimated scattered electrons to transverse locations on an image plane representative of the electrons' positions in the object.
Focus prosody of telephone numbers in Tokyo Japanese.
Lee, Yong-Cheol; Nambu, Satoshi; Cho, Sunghye
2018-05-01
Using production and perception experiments, this study examined whether the prosodic structure inherent to telephone numbers in Tokyo Japanese affects the realization of focus prosody as well as its perception. It was hypothesized that prosodic marking of focus differs by position within the digit groups of phone number strings. Overall, focus prosody of telephone numbers was not clearly marked, resulting in poor identification in perception. However, a difference between positions within digit groups was identified, reflecting a prosodic structure where one position is assigned an accentual peak instead of the other. The findings suggest that, conforming to a language-specific prosodic structure, focus prosody within a language can vary under the influence of a particular linguistic environment.
Experimental study of the focusing properties of a Gaussian Schell-model vortex beam
NASA Astrophysics Data System (ADS)
Wang, Fei; Zhu, Shijun; Cai, Yangjian
2011-08-01
We carry out an experimental and theoretical study of the focusing properties of a Gaussian Schell-model (GSM) vortex beam. It is found that we can shape the beam profile of the focused GSM vortex beam by varying its initial spatial coherence width. Focused dark hollow, flat-topped, and Gaussian beam spots can be obtained in our experiment, which will be useful for trapping particles. The experimental results agree well with the theoretical results.
Development of an Internet-Based Parent Training Intervention for Children with ASD
2014-10-01
had mean pretests scores that were significantly lower than did individuals with master’s degrees, all three groups per- formed comparably on the...focus groups with 8-10 key stakeholders to gain feedback on the structural elements of the program. Focus group members will participate in two focus... groups , three months apart. In the first focus group , 9 we will obtain feedback on the structure of the online systems training and self-directed
Dynamics of Cavitation Clouds within a High-Intensity Focused Ultrasonic Beam
2012-03-01
the cloud size. I. INTRODUCTION High-intensity focused ultrasound ( HIFU ), along with the associated cavitation, is used in a variety of fields. The...this experimental study, we generate a 500 kHz high-intensity focused ultrasonic ( HIFU ) beam, with pressure amplitude in the focal zone of up to 1.9 MPa... focused ultrasonic ( HIFU ) beam, with pressure amplitude in the focal zone of up to 1.9 MPa, in initially quiescent water. The resulting pressure field
Operational Characteristics of a High Voltage Dense Plasma Focus.
1985-11-01
A high voltage dense plasma focus powered by a single-stage Marx bank was designed, built and operated. The maximum bank parameters are: voltage--120...kV, energy--20 kJ, short-circuit current--600kA. The bank impedance is about 200 millohms. The plasma focus center electrode diameter is 1.27 cm. The...about 50 milliohms. The context of this work is established with a review of previous plasma focus theoretical, experimental and computational work and
Radiation Production by Charged Particle Beams Ejected from a Plasma Focus.
1981-02-01
The scope of this investigation concerns the development of a pulsed radiation source using the charged particle beam ejected from a plasma focus device...satellite components for radiation hardening and survivability. The plasma focus is operated in a modified geometry such that electron bursts which...a radiation facility. The plasma focus , identified as the Mark IV, is nominally rated at 34 kJ with a capacitance of 168 micro F at 20 kV. The
Ackermann, Mark R [Albuquerque, NM; Diels, Jean-Claude M [Albuquerque, NM
2007-06-26
An optical system comprising a concave primary mirror reflects light through an intermediate focus to a secondary mirror. The secondary mirror re-focuses the image to a final image plane. Optical limiter material is placed near the intermediate focus to optically limit the intensity of light so that downstream components of the optical system are protected from intense optical transients. Additional lenses before and/or after the intermediate focus correct optical aberrations.
Microwave and Millimeter Wave Imaging Using Synthetic Aperture Focusing and Holographical Techniques
NASA Technical Reports Server (NTRS)
Case, Joseph Tobias
2005-01-01
Microwave and millimeter wave nondestructive testing and evaluation (NDT&E) methods have shown great potential for determining material composition in composite structures, determining material thickness or debond thickness between two layers, and determining the location and size of flaws, defects, and anomalies. The same testing methods have also shown great potential to produce relatively high-resolution images of voids inside Spray On Foam Insulation (SOFI) test panels using real focused methods employing lens antennas. An alternative to real focusing methods are synthetic focusing methods. The essence of synthetic focusing is to match the phase of the scattered signal to measured points spaced regularly on a plane. Many variations of synthetic focusing methods have already been developed for radars, ultrasonic testing applications, and microwave concealed weapon detection. Two synthetic focusing methods were investigated; namely, a) frequency-domain synthetic aperture focusing technique (FDSAFT), and b) wide-band microwave holography. These methods were applied towards materials whose defects were of low dielectric contrast like air void in SOFI. It is important to note that this investigation used relatively low frequencies from 8.2 GHz to 26.5 GHz that are not conducive for direct imaging of the SOFI. The ultimate goal of this work has been to demonstrate the capability of these methods before they are applied to much higher frequencies such as the millimeter wave frequency spectrum (e.g., 30-300 GHz).
Polskaia, Nadia; Richer, Natalie; Dionne, Eliane; Lajoie, Yves
2015-02-01
Research has demonstrated clear advantages of using an external focus of attention in postural control tasks, presumably since it allows a more automatic control of posture to emerge. However, the influence of cognitive tasks on postural stability has produced discordant results. This study aimed to compare the effects of an internal focus of attention, an external focus of attention and a continuous cognitive task on postural control. Twenty healthy participants (21.4±2.6 years) were recruited for this study. They were asked to stand quietly on a force platform with their feet together in three different attentional focus conditions: an internal focus condition (minimizing movements of the hips), an external focus condition (minimizing movements of markers placed on the hips) and a cognitive task condition (silently counting the total number of times a single digit was verbalized in a 3-digit sequence comprised of 30 numbers). Results demonstrated improved stability while performing the cognitive task as opposed to the internal and external focus conditions, as evidenced by a reduction in sway area, sway variability in the anterior-posterior (AP) and medial-lateral (ML) directions, and mean velocity (ML only). Results suggest that the use of a continuous cognitive task permits attention to be withdrawn from the postural task, thereby facilitating a more automatic control of posture. Copyright © 2014 Elsevier B.V. All rights reserved.
Sidani, Souraya; Streiner, David; Leclerc, Chantale
2012-03-01
The abilities-focused approach demonstrated efficacy in promoting engagement of residents with dementia in care. The extent to which these resident outcomes can be replicated when the abilities-focused approach is implemented by nursing staff under the conditions of day-to-day practice was investigated in this study. The aim was to examine changes in resident outcomes before and after nursing staff' implementation of the abilities-focused approach and the contribution of this approach to resident outcomes. A one-group pretest-post-test design was used. Observational data were obtained from 65 residents with dementia. The data pertained to the implementation of abilities-focused strategies during episodes of morning care and residents' level of agitation, participation in morning care and physical and psychosocial functioning. The number of abilities-focused strategies used during morning care increased at post-test. No clinically important changes in resident outcomes were observed over time. However, the implementation of some strategies was associated with residents' participation in care and functioning at post-test. The results provided preliminary evidence of the effectiveness of the abilities-focused approach in maintaining functioning in people with dementia. Additional research is needed to understand the mechanism underlying the effects of this person-centred approach to care on resident outcomes. Implementation of the abilities-focused approach assists people with dementia to participate in morning care. © 2011 Blackwell Publishing Ltd.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Volker, Arno; Hunter, Alan
Anisotropic materials are being used increasingly in high performance industrial applications, particularly in the aeronautical and nuclear industries. Some important examples of these materials are composites, single-crystal and heavy-grained metals. Ultrasonic array imaging in these materials requires exact knowledge of the anisotropic material properties. Without this information, the images can be adversely affected, causing a reduction in defect detection and characterization performance. The imaging operation can be formulated in two consecutive and reciprocal focusing steps, i.e., focusing the sources and then focusing the receivers. Applying just one of these focusing steps yields an interesting intermediate domain. The resulting common focusmore » point gather (CFP-gather) can be interpreted to determine the propagation operator. After focusing the sources, the observed travel-time in the CFP-gather describes the propagation from the focus point to the receivers. If the correct propagation operator is used, the measured travel-times should be the same as the time-reversed focusing operator due to reciprocity. This makes it possible to iteratively update the focusing operator using the data only and allows the material to be imaged without explicit knowledge of the anisotropic material parameters. Furthermore, the determined propagation operator can also be used to invert for the anisotropic medium parameters. This paper details the proposed technique and demonstrates its use on simulated array data from a specimen of Inconel single-crystal alloy commonly used in the aeronautical and nuclear industries.« less
van de Velde, Daan J.; Schiller, Niels O.; van Heuven, Vincent J.; Levelt, Claartje C.; van Ginkel, Joost; Beers, Mieke; Briaire, Jeroen J.; Frijns, Johan H. M.
2017-01-01
This study aimed to find the optimal filter slope for cochlear implant simulations (vocoding) by testing the effect of a wide range of slopes on the discrimination of emotional and linguistic (focus) prosody, with varying availability of F0 and duration cues. Forty normally hearing participants judged if (non-)vocoded sentences were pronounced with happy or sad emotion, or with adjectival or nominal focus. Sentences were recorded as natural stimuli and manipulated to contain only emotion- or focus-relevant segmental duration or F0 information or both, and then noise-vocoded with 5, 20, 80, 120, and 160 dB/octave filter slopes. Performance increased with steeper slopes, but only up to 120 dB/octave, with bigger effects for emotion than for focus perception. For emotion, results with both cues most closely resembled results with F0, while for focus results with both cues most closely resembled those with duration, showing emotion perception relies primarily on F0, and focus perception on duration. This suggests that filter slopes affect focus perception less than emotion perception because for emotion, F0 is both more informative and more affected. The performance increase until extreme filter slope values suggests that much performance improvement in prosody perception is still to be gained for CI users. PMID:28599540
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, Yunpeng; Li, En, E-mail: lien@uestc.edu.cn; Guo, Gaofeng
2014-09-15
A pair of spot-focusing horn lens antenna is the key component in a free-space measurement system. The electromagnetic constitutive parameters of a planar sample are determined using transmitted and reflected electromagnetic beams. These parameters are obtained from the measured scattering parameters by the microwave network analyzer, thickness of the sample, and wavelength of a focused beam on the sample. Free-space techniques introduced by most papers consider the focused wavelength as the free-space wavelength. But in fact, the incident wave projected by a lens into the sample approximates a Gaussian beam, thus, there has an elongation of the wavelength in themore » focused beam and this elongation should be taken into consideration in dielectric and magnetic measurement. In this paper, elongation of the wavelength has been analyzed and measured. Measurement results show that the focused wavelength in the vicinity of the focus has an elongation of 1%–5% relative to the free-space wavelength. Elongation's influence on the measurement result of the permittivity and permeability has been investigated. Numerical analyses show that the elongation of the focused wavelength can cause the increase of the measured value of the permeability relative to traditionally measured value, but for the permittivity, it is affected by several parameters and may increase or decrease relative to traditionally measured value.« less
Combinational light emitting diode-high frequency focused ultrasound treatment for HeLa cell.
Choe, Se-Woon; Park, Kitae; Park, Chulwoo; Ryu, Jaemyung; Choi, Hojong
2017-12-01
Light sources such as laser and light emitting diode or ultrasound devices have been widely used for cancer therapy and regenerative medicines, since they are more cost-effective and less harmful than radiation therapy, chemotherapy or magnetic treatment. Compared to laser and low intensity ultrasound techniques, light emitting diode and high frequency focused ultrasound shows enhanced therapeutic effects, especially for small tumors. We propose combinational light emitting diode-high frequency focused ultrasound treatment for human cervical cancer HeLa cells. Individual red, green, and blue light emitting diode light only, high frequency focused ultrasound only, or light emitting diode light combined with high frequency focused ultrasound treatments were applied in order to characterize the responses of HeLa cells. Cell density exposed by blue light emitting diode light combined with high frequency focused ultrasound (2.19 ± 0.58%) was much lower than that of cells exposed by red and green light emitting diode lights (81.71 ± 9.92% and 61.81 ± 4.09%), blue light emitting diode light (11.19 ± 2.51%) or high frequency focused ultrasound only (9.72 ± 1.04%). We believe that the proposed combinational blue light emitting diode-high frequency focused ultrasound treatment could have therapeutic benefits to alleviate cancer cell proliferation.
A wide field-of-view microscope based on holographic focus grid
NASA Astrophysics Data System (ADS)
Wu, Jigang; Cui, Xiquan; Zheng, Guoan; Lee, Lap Man; Yang, Changhuei
2010-02-01
We have developed a novel microscope technique that can achieve wide field-of-view (FOV) imaging and yet possess resolution that is comparable to conventional microscope. The principle of wide FOV microscope system breaks the link between resolution and FOV magnitude of traditional microscopes. Furthermore, by eliminating bulky optical elements from its design and utilizing holographic optical elements, the wide FOV microscope system is more cost-effective. In our system, a hologram was made to focus incoming collimated beam into a focus grid. The sample is put in the focal plane and the transmissions of the focuses are detected by an imaging sensor. By scanning the incident angle of the incoming beam, the focus grid will scan across the sample and the time-varying transmission can be detected. We can then reconstruct the transmission image of the sample. The resolution of microscopic image is limited by the size of the focus formed by the hologram. The scanning area of each focus spot is determined by the separation of the focus spots and can be made small for fast imaging speed. We have fabricated a prototype system with a 2.4-mm FOV and 1-μm resolution. The prototype system was used to image onion skin cells for a demonstration. The preliminary experiments prove the feasibility of the wide FOV microscope technique, and the possibility of a wider FOV system with better resolution.
Fast photorefractive self focusing in InP:Fe semiconductor at near infrared wavelengths
NASA Astrophysics Data System (ADS)
Wolfersberger, Delphine; Dan, Cristian; Khelfaoui, Naïma; Fressengeas, Nicolas; Hervé, Leblond
2008-04-01
Self-trapping of optical beams in photorefractive (PR) materials at telecommunications wavelengths has been studied at steady state in insulators such as SBN [1] and in semiconductor InP:Fe [2], CdTe [3]. PR self-focusing and soliton interactions in semiconductors find interesting applications in optical communications such as optical routing and interconnections because of several advantages over insulators: their sensitivity to near-infrared wavelengths and shorter response time. Photorefractive self focusing in InP:Fe is characterized as a function of beam intensity and temperature. Transient self focusing is found to occur on two time scales for input intensities of tens of W/cm2 (one on the order of tens of μs, one on the order of milliseconds). A theory developed describes the photorefractive self focusing in InP:Fe and confirmed by steady state and transient regime measurements. PR associated phenomena (bending and self focusing) are taking place in InP:Fe as fast as a μs for intensities on the order of 10W/cm2 at 1.06 μm. Currently we are conducting more experiments in order to estimate the self focusing response time at 1.55μm, to clarify the temporal dynamic of the self focusing and to build up a demonstrator of fast optical routing by photorefractive spatial solitons interactions.
Herbert, Eric; Pernot, Mathieu; Montaldo, Gabriel; Fink, Mathias; Tanter, Mickael
2009-01-01
An aberration correction method based on the maximization of the wave intensity at the focus of an emitting array is presented. The potential of this new adaptive focusing technique is investigated for ultrasonic focusing in biological tissues. The acoustic intensity is maximized non invasively through the direct measurement or indirect estimation of the beam energy at the focus for a series of spatially coded emissions. For ultrasonic waves, the acoustic energy at the desired focus can be indirectly estimated from the local displacements induced in tissues by the ultrasonic radiation force of the beam. Based on the measurement of these displacements, this method allows the precise estimation of the phase and amplitude aberrations and consequently the correction of aberrations along the beam travel path. The proof of concept is first performed experimentally using a large therapeutic array with strong electronic phase aberrations (up to 2π). Displacements induced by the ultrasonic radiation force at the desired focus are indirectly estimated using the time shift of backscattered echoes recorded on the array. The phase estimation is deduced accurately using a direct inversion algorithm which reduces the standard deviation of the phase distribution from σ = 1.89 before correction to σ = 0.53 following correction. The corrected beam focusing quality is verified using a needle hydrophone. The peak intensity obtained through the aberrator is found to be −7.69 dB below the reference intensity obtained without any aberration. Using the phase correction, a sharp focus is restored through the aberrator with a relative peak intensity of −0.89 dB. The technique is tested experimentally using a linear transmit/receive array through a real aberrating layer. The array is used to automatically correct its beam quality, as it both generates the radiation force with coded excitations and indirectly estimates the acoustic intensity at the focus with speckle tracking. This technique could have important implications in the field of High Intensity Focused Ultrasound even in complex configurations such as transcranial, transcostal or deep seated organs. PMID:19942526
What about N? A methodological study of sample-size reporting in focus group studies.
Carlsen, Benedicte; Glenton, Claire
2011-03-11
Focus group studies are increasingly published in health related journals, but we know little about how researchers use this method, particularly how they determine the number of focus groups to conduct. The methodological literature commonly advises researchers to follow principles of data saturation, although practical advise on how to do this is lacking. Our objectives were firstly, to describe the current status of sample size in focus group studies reported in health journals. Secondly, to assess whether and how researchers explain the number of focus groups they carry out. We searched PubMed for studies that had used focus groups and that had been published in open access journals during 2008, and extracted data on the number of focus groups and on any explanation authors gave for this number. We also did a qualitative assessment of the papers with regard to how number of groups was explained and discussed. We identified 220 papers published in 117 journals. In these papers insufficient reporting of sample sizes was common. The number of focus groups conducted varied greatly (mean 8.4, median 5, range 1 to 96). Thirty seven (17%) studies attempted to explain the number of groups. Six studies referred to rules of thumb in the literature, three stated that they were unable to organize more groups for practical reasons, while 28 studies stated that they had reached a point of saturation. Among those stating that they had reached a point of saturation, several appeared not to have followed principles from grounded theory where data collection and analysis is an iterative process until saturation is reached. Studies with high numbers of focus groups did not offer explanations for number of groups. Too much data as a study weakness was not an issue discussed in any of the reviewed papers. Based on these findings we suggest that journals adopt more stringent requirements for focus group method reporting. The often poor and inconsistent reporting seen in these studies may also reflect the lack of clear, evidence-based guidance about deciding on sample size. More empirical research is needed to develop focus group methodology.
Wiggler plane focusing in a linear free electron laser
Scharlemann, Ernst T.
1988-01-01
Free electron laser apparatus that provides a magnetic centering force to turn or focus a non-axial electron toward the longitudinal axis as desired. The focusing effect is provided by wiggler magnet pole faces that are approximately parabolically shaped.
The Effect of Focusing on the Cognitive Processes of Learning Disabled Children.
ERIC Educational Resources Information Center
Maier, Arlee S.
1980-01-01
The effect of focused or preorganized instruction on the mental operations of 64 learning disabled (LD) children (8 to 12 years old) was examined. Results indicated focused instruction had a positive effect on cognitive functioning. (Author)
Dynamics of a Focussed Discharge.
This report describes theoretical and experimental investigations on the dynamics of a dense plasma focus . The characteristics of the focus in terms...also described. The results of a preliminary theoretical investigation of the heating of a dense plasma focus by a laser is given.
ION BEAM FOCUSING MEANS FOR CALUTRON
Backus, J.G.
1959-06-01
An ion beam focusing arrangement for calutrons is described. It provides a virtual focus of origin for the ion beam so that the ions may be withdrawn from an arc plasma of considerable width providing greater beam current and accuracy. (T.R.H.)
McRackan, Theodore R; Velozo, Craig A; Holcomb, Meredith A; Camposeo, Elizabeth L; Hatch, Jonathan L; Meyer, Ted A; Lambert, Paul R; Melvin, Cathy L; Dubno, Judy R
2017-10-01
No instrument exists to assess quality of life (QOL) in adult cochlear implant (CI) users that has been developed and validated using accepted scientific standards. To develop a CI-specific QOL instrument for adults in accordance with the Patient Reported Outcomes Measurement Information System (PROMIS) guidelines. As required in the PROMIS guidelines, patient focus groups participated in creation of the initial item bank. Twenty-three adult CI users were divided into 1 of 3 focus groups stratified by word recognition ability. Three moderator-led focus groups were conducted based on grounded theory on December 3, 2016. Two reviewers independently analyzed focus group recordings and transcripts, with a third reviewer available to resolve discrepancies. All data were reviewed and reported according to the Consolidated Criteria for Reporting Qualitative Research. The setting was a tertiary referral center. Coded focus group data. The 23 focus group participants (10 [43%] female; mean [range] age, 68.1 [46.2-84.2] years) represented a wide range of income levels, education levels, listening modalities, CI device manufacturers, duration of CI use, and age at implantation. Data saturation was determined to be reached before the conclusion of each of the focus groups. After analysis of the transcripts, the central themes identified were communication, emotion, environmental sounds, independence and work function, listening effort, social isolation and ability to socialize, and sound clarity. Cognitive interviews were carried out on 20 adult CI patients who did not participate in the focus groups to ensure item clarity. Based on these results, the initial QOL item bank and prototype were developed. Patient focus groups drawn from the target population are the preferred method of identifying content areas and domains for developing the item bank for a CI-specific QOL instrument. Compared with previously used methods, the use of patient-centered item development for a CI-specific QOL instrument will more accurately reflect patient experience and increase our understanding of how CI use affects QOL.
Taft, Tiffany H; Keefer, Laurie; Keswani, Rajesh N
2011-09-01
No study to date has evaluated the relationship between coping style, burnout, and psychological functioning among gastroenterologists (GEs). This study aims to explore this relationship. Physician stress and burnout are widely studied and associated with notably poorer outcomes for both physicians and their patients. Coping is a multidimensional construct that individuals use to adapt to stressful situations. To mitigate stress, physicians may use problem-focused or emotion-focused coping strategies. Four hundred ten GE fellows and attending physicians provided information about their practice, coping styles, level of burnout, psychological distress, job-related self-efficacy, and demographic background. Participants recruited from the American Society of Gastrointestinal Endoscopy membership through email completed a series of online questionnaires. We found no significant relationships between workload and reported burnout. GEs with greater psychological distress were more likely to have an endoscopic complication in the past year. GEs that use problem-focused coping strategies were less likely to report an event in the past year, although we did not identify a significant predictive relationship between these variables. Significant differences in coping styles existed for sex and having a physician parent. Female GEs were more likely to use problem-focused coping strategies, and GEs with a physician parent were more likely to use emotion-focused strategies. Using problem-focused coping predicted decreased levels of burnout and psychological distress, and increased job-related self-efficacy. Emotion-focused coping showed opposite predictive results. Coping strategies accounted for 3% to 19% of the variance in these outcomes. GEs use both problem-focused and emotion-focused coping strategies. Sex and having a physician parent are likely predictors of coping and psychological well-being. Problem-focused coping is a potentially more adaptive coping strategy in gastroenterology practice and may explain lower levels of reported burnout, distress, and increased job-related self-efficacy.
Conducting a team-based multi-sited focused ethnography in primary care.
Bikker, A P; Atherton, H; Brant, H; Porqueddu, T; Campbell, J L; Gibson, A; McKinstry, B; Salisbury, C; Ziebland, S
2017-09-12
Focused ethnography is an applied and pragmatic form of ethnography that explores a specific social phenomenon as it occurs in everyday life. Based on the literature a problem-focused research question is formulated before the data collection. The data generation process targets key informants and situations so that relevant results on the pre-defined topic can be obtained within a relatively short time-span. As part of a theory based evaluation of alternative forms of consultation (such as video, phone and email) in primary care we used the focused ethnographic method in a multisite study in general practice across the UK. To date there is a gap in the literature on using focused ethnography in healthcare research.The aim of the paper is to build on the various methodological approaches in health services research by presenting the challenges and benefits we encountered whilst conducing a focused ethnography in British primary care. Our considerations are clustered under three headings: constructing a shared understanding, dividing the tasks within the team, and the functioning of the focused ethnographers within the broader multi-disciplinary team.As a result of using this approach we experienced several advantages, like the ability to collect focused data in several settings simultaneously within in a short time-span. Also, the sharing of experiences and interpretations between the researchers contributed to a more holistic understanding of the research topic. However, mechanisms need to be in place to facilitate and synthesise the observations, guide the analysis, and to ensure that all researchers feel engaged. Reflection, trust and flexibility among the team members were crucial to successfully adopt a team focused ethnographic approach. When used for policy focussed applied healthcare research a team-based multi-sited focused ethnography can uncover practices and understandings that would not be apparent through surveys or interviews alone. If conducted with care, it can provide timely findings within the fast moving context of healthcare policy and research.
Attention focus and self-touch in toddlers: The moderating effect of attachment security.
Ito-Jäger, Sachiyo; Howard, Amanda R; Purvis, Karyn B; Cross, David R
2017-08-01
The superior self-regulation and attention-regulation abilities of securely attached children have been repeatedly demonstrated. However, the mechanisms that allow securely attached children to exhibit higher levels of attention focus than insecurely attached (anxious-ambivalent and anxious-avoidant) children need to be explored. One possible mechanism that has been hypothesized to play a role in focusing attention is self-touch. Previous research has shown that 10-year-old children exhibit more bilateral self-touch (i.e., both hands are simultaneously moving onto each other or on the body, and both hands are in contact with each other or with the body), but not lateral self-touch (i.e., one hand is moving on the other hand or on the body, and the hand is in contact with the other hand or with the body), when they focus attention on a task. Because bilateral coordination is still developing during childhood, we expected that lateral self-touch, instead of bilateral self-touch, may be associated with attention focus for toddlers. The objectives of the present study were to examine whether securely attached toddlers exhibit more self-touch, particularly lateral self-touch, while they focus on a task than while they do not focus on a task. We expected to find that the association between lateral self-touch and attention focus is not as strong for insecurely attached toddlers. Data from forty-nine mother-child dyads were employed for analyses. The attachment classification of the children was determined using the Strange Situation. The duration of attention focus and self-touch behavior during a reading task were coded. An association between lateral self-touch and attention focus was found for children of all attachment classifications. This association was particularly strong for securely attached children. We discuss the possibility that securely attached toddlers may use lateral self-touch to regulate attention. Copyright © 2017 Elsevier Inc. All rights reserved.
Three-dimensional envelope instability in periodic focusing channels
NASA Astrophysics Data System (ADS)
Qiang, Ji
2018-03-01
The space-charge driven envelope instability can be of great danger in high intensity accelerators and was studied using a two-dimensional (2D) envelope model and three-dimensional (3D) macroparticle simulations before. In this paper, we study the instability for a bunched beam using a three-dimensional envelope model in a periodic solenoid and radio-frequency (rf) focusing channel and a periodic quadrupole and rf focusing channel. This study shows that when the transverse zero current phase advance is below 90 ° , the beam envelope can still become unstable if the longitudinal zero current phase advance is beyond 90 ° . For the transverse zero current phase advance beyond 90 ° , the instability stopband width becomes larger with the increase of the longitudinal focusing strength and even shows different structure from the 2D case when the longitudinal zero current phase advance is beyond 90 ° . Breaking the symmetry of two longitudinal focusing rf cavities and the symmetry between the horizontal focusing and the vertical focusing in the transverse plane in the periodic quadrupole and rf channel makes the instability stopband broader. This suggests that a more symmetric accelerator lattice design might help reduce the range of the envelope instability in parameter space.
NASA Astrophysics Data System (ADS)
Fessl, Tomas; Ben-Yaish, Shai; Vacha, Frantisek; Adamec, Frantisek; Zalevsky, Zeev
2009-07-01
Imaging of small objects such as single molecules, DNA clusters and single bacterial cells is problematic not only due to the lateral resolution that is obtainable in currently existing microscopy but also, and as much fundamentally limiting, due to the lack of sufficient axial depth of focus to have the full object focused simultaneously. Extension in depth of focus is helpful also for single molecule steady state FRET measurements. In this technique it is crucial to obtain data from many well focused molecules, which are often located in different axial depths. In this paper we present the implementation of an all-optical and a real time technique of extension in the depth of focus that may be incorporated in any high NA microscope system and to be used for the above mentioned applications. We demonstrate experimentally how after the integration of special optical element in high NA 100× objective lens of a single molecule imaging microscope system, the depth of focus is significantly improved while maintaining the same lateral resolution in imaging applications of incorporated groups of molecules, DNA constructs and clusters inside bacterial cells.
AXAF VETA-I mirror ring focus measurements
NASA Technical Reports Server (NTRS)
Tananbaum, H. D.; Zhao, P.
1994-01-01
The AXAF VETA-I mirror ring focus measurements were made with an HRI (microchannel plate) X-ray detector. The ring focus is a sharply focused ring formed by X-rays before they reach the VEAT-I focal plane. It is caused by spherical aberrations due to the finite source distance and the despace in the VETA-I test. The ring focus test reveals some aspects fo the test system distortions and the mirror surface figure which are difficult or impossible to detect at the focal plane. The test results show periodic modulations of the ring radius and width which could be caused by gravity, thermal, and/or epoxy shrinkage distortions. The strongest component of the modulation had a 12-fold symmetry, because these distortions were exerted on the mirror through 12 flexures of the VETA-I mount. Ring focus models were developed to simulate the ring image. The models were compared with the data to understand the test system distortions and the mirror glass imperfection. Further studies will be done to complete this work. The ring focus measurement is a very powerful test. We expect that a similar test for the finally assembled mirror of AXAD-I will be highly valuable.
Dynamics of focused femtosecond laser pulse during photodisruption of crystalline lens
NASA Astrophysics Data System (ADS)
Gupta, Pradeep Kumar; Singh, Ram Kishor; Sharma, R. P.
2018-04-01
Propagation of laser pulses of femtosecond time duration (focused through a focusing lens inside the crystalline lens) has been investigated in this paper. Transverse beam diffraction, group velocity dispersion, graded refractive index structure of the crystalline lens, self-focusing, and photodisruption in which plasma is formed due to the high intensity of laser pulses through multiphoton ionization have been taken into account. The model equations are the modified nonlinear Schrödinger equation along with a rate equation that takes care of plasma generation. A close analysis of model equations suggests that the femtosecond laser pulse duration is critical to the breakdown in the lens. Our numerical simulations reveal that the combined effect of self-focusing and multiphoton ionization provides the breakdown threshold. During the focusing of femtosecond laser pulses, additional spatial pulse splitting arises along with temporal splitting. This splitting of laser pulses arises on account of self-focusing, laser induced breakdown, and group velocity distribution, which modifies the shape of laser pulses. The importance of the present study in cavitation bubble generation to improve the elasticity of the eye lens has also been discussed in this paper.
Attentional Focus and Grip Width Influences on Bench Press Resistance Training.
Calatayud, Joaquin; Vinstrup, Jonas; Jakobsen, Markus D; Sundstrup, Emil; Colado, JuanCarlos; Andersen, Lars L
2018-04-01
This study evaluated the influence of different attentional foci for varied grip widths in the bench press. Eighteen resistance-trained men were familiarized with the procedure and performed a one-repetition maximum (1RM) test during Session 1. In Session 2, they used three different standardized grip widths (100%, 150%, and 200% of biacromial width distance) in random order at 50% of 1RM while also engaged in three different attention focus conditions (external focus on the bench press, internal focus on pectoralis major muscles, and internal focus on triceps brachii muscles). Surface electromyography (EMG) signals were recorded from the triceps brachii and pectoralis major, and peak EMG of the filtered signals were normalized to maximum EMG of each muscle. Both grip width and focus influenced the muscle activity level, but there were no significant interactions between these variables. Exploratory analyses suggested that an internal focus may slightly (4%-6%) increase pectoralis major activity at wider grip widths and triceps brachii activity at narrower grip widths, but this should be confirmed or rejected in a study with a larger sample size or through a meta-analysis of research to date.
Focused and shifting attention in children with heavy prenatal alcohol exposure.
Mattson, Sarah N; Calarco, Katherine E; Lang, Aimée R
2006-05-01
Attention deficits are a hallmark of the teratogenic effects of alcohol. However, characterization of these deficits remains inconclusive. Children with heavy prenatal alcohol exposure and nonexposed controls were evaluated using a paradigm consisting of three conditions: visual focus, auditory focus, and auditory-visual shift of attention. For the focus conditions, participants responded manually to visual or auditory targets. For the shift condition, participants alternated responses between visual targets and auditory targets. For the visual focus condition, alcohol-exposed children had lower accuracy and slower reaction time for all intertarget intervals (ITIs), while on the auditory focus condition, alcohol-exposed children were less accurate but displayed slower reaction time only on the longest ITI. Finally, for the shift condition, the alcohol-exposed group was accurate but had slowed reaction times. These results indicate that children with heavy prenatal alcohol exposure have pervasive deficits in visual focused attention and deficits in maintaining auditory attention over time. However, no deficits were noted in the ability to disengage and reengage attention when required to shift attention between visual and auditory stimuli, although reaction times to shift were slower. Copyright (c) 2006 APA, all rights reserved.
Managing hindering self-focused attention in counseling sessions.
Wei, Meifen; Yi, Fei; Carrera, Stephanie G; Botello, Raquel; Sung, Duk-Hae
2017-03-01
This study examined the moderation effects of management strategies on the association between hindering self-focused attention and counseling self-efficacy. Participants were 160 counselor trainees. A hierarchical regression was used to analyze the data, and a simple effect analysis was used to explore the nature of the interaction. Results indicated that, for trainees who used more basic counseling techniques, counseling self-efficacy remained the same no matter their hindering self-focused attention experiences. However, for those who used less basic counseling techniques, their counseling self-efficacy dropped when they had more experiences of hindering self-focused attention. Similarly, for trainees who used more self-awareness to understand clients, these trainees reported a similar level of counseling self-efficacy no matter their hindering self-focused attention experiences. Conversely, for those who used less self-awareness as a tool to understand their clients during their sessions, their counseling self-efficacy decreased when they had more experiences of hindering self-focused attention. This is the first study that extends the literature on direct, linear relationships between hindering self-focused attention and counseling self-efficacy. Results suggested two strategies (i.e., use of basic counseling techniques and use of self-awareness to understand clients) significantly moderate the above association.
Focusing and depth of field in photography: application in dermatology practice.
Taheri, Arash; Yentzer, Brad A; Feldman, Steven R
2013-11-01
Conventional photography obtains a sharp image of objects within a given 'depth of field'; objects not within the depth of field are out of focus. In recent years, digital photography revolutionized the way pictures are taken, edited, and stored. However, digital photography does not result in a deeper depth of field or better focusing. In this article, we briefly review the concept of depth of field and focus in photography as well as new technologies in this area. A deep depth of field is used to have more objects in focus; a shallow depth of field can emphasize a subject by blurring the foreground and background objects. The depth of field can be manipulated by adjusting the aperture size of the camera, with smaller apertures increasing the depth of field at the cost of lower levels of light capture. Light-field cameras are a new generation of digital cameras that offer several new features, including the ability to change the focus on any object in the image after taking the photograph. Understanding depth of field and camera technology helps dermatologists to capture their subjects in focus more efficiently. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
The flexible focus: whether spatial attention is unitary or divided depends on observer goals.
Jefferies, Lisa N; Enns, James T; Di Lollo, Vincent
2014-04-01
The distribution of visual attention has been the topic of much investigation, and various theories have posited that attention is allocated either as a single unitary focus or as multiple independent foci. In the present experiment, we demonstrate that attention can be flexibly deployed as either a unitary or a divided focus in the same experimental task, depending on the observer's goals. To assess the distribution of attention, we used a dual-stream Attentional Blink (AB) paradigm and 2 target pairs. One component of the AB, Lag-1 sparing, occurs only if the second target pair appears within the focus of attention. By varying whether the first-target-pair could be expected in a predictable location (always in-stream) or not (unpredictably in-stream or between-streams), observers were encouraged to deploy a divided or a unitary focus, respectively. When the second-target-pair appeared between the streams, Lag-1 sparing occurred for the Unpredictable group (consistent with a unitary focus) but not for the Predictable group (consistent with a divided focus). Thus, diametrically different outcomes occurred for physically identical displays, depending on the expectations of the observer about where spatial attention would be required.
Azimuthal resolution degradation due to ocean surface motion in focused arrays and SARS
NASA Astrophysics Data System (ADS)
1990-06-01
During the meeting at WHOI (5-18-90), a discussion arose of the ability of the focused array to simulate the R/v ratios typical of airborne and/or spaceborne SARs. In particular, the ability was questioned of the focused array to yield the same azimuthal resolution, rho, as the SAR. Although the focused array can be sampled to yield the same azimuthal resolution as the SAR, it is likely that the images generated by the focused array will not be identical to those produced by a SAR with the same azimuth resolution. For a true SAR, biases in the Doppler history of azimuthally traveling waves due to their along-track motion will cause shifts in their apparent position. This will cause waves which are physically at one location to shift over several pixel widths in the image. The limited swath width of the focused array will prevent if from observing scattered power from waves falling outside the swath, thus such waves will not affect the image formed within the swath, as would happen in the SAR. Thus, it is likely that the focused array will not yield the same image as a SAR having the same resolution.
Halbach array type focusing actuator for small and thin optical data storage device
NASA Astrophysics Data System (ADS)
Lee, Sung Q.; Park, Kang-Ho; Paek, Mun Chul
2004-09-01
The small form factor optical data storage devices are developing rapidly nowadays. Since it is designed for portable and compatibility with flesh memory, its components such as disk, head, focusing actuator, and spindle motor should be assembled within 5 mm. The thickness of focusing actuator is within 2 mm and the total working range is +/-100um, with the resolution of less than 1μm. Since the thickness is limited tightly, it is hard to place the yoke that closes the magnetic circuit and hard to make strong flux density without yoke. Therefore, Halbach array is adopted to increase the magnetic flux of one side without yoke. The proposed Halbach array type focusing actuator has the advantage of thin actuation structure with sacrificing less flex density than conventional magnetic array. The optical head unit is moved on the swing arm type tracking actuator. Focusing coil is attached to swing arm, and Halbach magnet array is positioned at the bottom of deck along the tracking line, and focusing actuator exerts force by the Fleming's left hand rule. The dynamics, working range, control resolution of focusing actuator are analyzed and performed.
Structure resonances due to space charge in periodic focusing channels
NASA Astrophysics Data System (ADS)
Li, Chao; Jameson, R. A.
2018-02-01
The Vlasov-Poisson model is one of the most effective methods to study the space charge dominated beam evolution self-consistently in a periodic focusing channel. Since the approach to get the solution with this model is not trivial, previous studies are limited in degenerated conditions, either in smoothed channel (constant focusing) [I. Hofmann, Phys. Rev. E 57, 4713 (1998)] or in alternating gradient focusing channel with equal initial beam emittance condition in the degrees of freedom [I. Hofmann et al., Part. Accel. 13, 145 (1983); Chao Li et al., THOBA02, IPAC2016]. To establish a basis, we intentionally limit this article to the study of the pure transverse periodic focusing lattice with arbitrary initial beam condition, and the same lattice structure in both degrees of freedom, but with possibility of different focusing strengths. This will show the extension of the existing work. The full Hamiltonian is invoked for a pure transverse focusing lattice in various initial beam conditions, revealing different mode structure and additional modes beyond those of the degenerated cases. Application of the extended method to realistic lattices (including longitudinal accelerating elements) and further details will then reveal many new insights, and will be presented in later work.
NASA Technical Reports Server (NTRS)
Tenney, Darrel R.
2004-01-01
Six long-term technology focus areas are: 1. Environmentally Friendly, Clean Burning Engines. Focus: Develop innovative technologies to enable intelligent turbine engines that significantly reduce harmful emissions while maintaining high performance and increasing reliability. 2. New Aircraft Energy Sources and Management. Focus: Discover new energy sources and intelligent management techniques directed towards zero emissions and enable new vehicle concepts for public mobility and new science missions. 3. Quiet Aircraft for Community Friendly Service. Focus: Develop and integrate noise reduction technology to enable unrestricted air transportation service to all communities. 4. Aerodynamic Performance for Fuel Efficiency. Focus: Improve aerodynamic efficiency,structures and materials technologies, and design tools and methodologies to reduce fuel burn and minimize environmental impact and enable new vehicle concepts and capabilities for public mobility and new science missions. 5. Aircraft Weight Reduction and Community Access. Focus: Develop ultralight smart materials and structures, aerodynamic concepts, and lightweight subsystems to increase vehicle efficiency, leading to high altitude long endurance vehicles, planetary aircraft, advanced vertical and short takeoff and landing vehicles and beyond. 6. Smart Aircraft and Autonomous Control. Focus: Enable aircraft to fly with reduced or no human intervention, to optimize flight over multiple regimes, and to provide maintenance on demand towards the goal of a feeling, seeing, sensing, sentient air vehicle.
A Content Analysis of Unique Selling Propositions of Tobacco Print Ads.
Johnson Shen, Megan; Banerjee, Smita C; Greene, Kathryn; Carpenter, Amanda; Ostroff, Jamie S
2017-03-01
We describe the unique selling propositions (USPs) (propositions used to convince customers to use a particular brand/product by focusing on the unique benefit) of print tobacco ads. A qualitative content analysis was conducted of print tobacco ads (N = 171) selected from August 2012 to August 2013 for cigarettes, moist snuff, e-cigarettes, cigars, and snus to determine the content and themes of USPs for tobacco ads. Cigarette ad USP themes focused on portraying the product as attractive; moist snuff ads focused on portraying product as masculine; cigar ads focused on selling a "high end product;" and new and emerging tobacco products (e-cigarette, snus) focused on directly comparing these products to cigarettes. Whereas traditional tobacco product ads used USPs focused on themes of enjoyment and pleasure (eg, attractive for cigarettes, "high end product" for cigars), new and emerging tobacco product ads offered the unique benefit (USP) of their product being a better and "safer" alternative to traditional tobacco products. Snuff's USPs focused nearly exclusively on the masculinity of their products. Our results provide targets for potential tobacco regulatory actions that could be implemented to reduce demand for tobacco products by reducing their perceived unique benefits.
Somatic focus/awareness: Relationship to negative affect and pain in chronic pain patients
O’Brien, Erin M.; Atchison, James W.; Gremillion, Henry A.; Waxenberg, Lori B.; Robinson, Michael E.
2009-01-01
Somatic focus refers to the tendency to notice and report physical symptoms, and has been investigated in relation to chronically painful conditions. This study investigated the relationship between somatic focus, as measured by the Pennebaker Inventory of Limbic Languidness (PILL), negative affect and pain. A secondary purpose of the present study was to examine sex differences in these relationships. Participants included 280 chronic pain patients (69.6% females, 88.9% Caucasian), who completed a battery of self-report measures on somatic focus, pain, negative affect, coping, and dysfunction. Results for the overall sample revealed that the PILL shares considerable variance with measures of negative affect, particularly with the physiological components of anxiety and depression. When the results were analyzed separately for male and female patients, it was found that several components of negative affect and cognitive factors play a stronger role in predicting somatic focus among men compared to women. Additional analyses then examined whether somatic focus was predictive of male and female patients’ pain reports. Results indicated that somatic focus explained a small, but unique amount of variance in female patients’ pain reports, which differed from the relationship observed among male patients. PMID:17524684
Promoting health: media advocacy opportunities in English- and Spanish-language masthead editorials.
Lingas, Elena O
2013-01-01
This study examines two newspapers' editorial coverage of issues related to the Healthy People 2010 focus areas and compares the two newspapers. A qualitative study. Two Los Angeles, California, newspapers. The masthead editorials of the Los Angeles Times and La Opinión in the year following the release of Healthy People 2010. A structured data abstraction instrument was used for descriptive coding. Correspondence to 1 of the 28 Healthy People 2010 focus areas determined whether domestic editorials were about health. An ethnographic content analysis. There were 1075 editorials from the Los Angeles Times and 361 from La Opinión; 17% were focused on domestic health issues. Three Healthy People 2010 focus areas dominated: Environmental Health, Injury and Violence Prevention, and Access to Quality Health Services. Ten focus areas did not receive a single mention in the Los Angeles Times, and 19 focus areas lacked editorials in La Opinión. Editorial writers regularly tackled issues related to a Healthy People 2010 focus area. Public health practitioners can meet with their local newspaper editorial board and discuss the nation's health objectives as manifested by Healthy People 2020 and the National Prevention Strategy, thereby promoting policies that support individual and population health.
NASA Astrophysics Data System (ADS)
Hashemzadeh, M.
2018-01-01
Self-focusing and defocusing of Gaussian laser beams in collisional inhomogeneous plasmas are investigated in the presence of various laser intensities and linear density and temperature ramps. Considering the ponderomotive force and using the momentum transfer and energy equations, the nonlinear electron density is derived. Taking into account the paraxial approximation and nonlinear electron density, a nonlinear differential equation, governing the focusing and defocusing of the laser beam, is obtained. Results show that in the absence of ramps the laser beam is focused between a minimum and a maximum value of laser intensity. For a certain value of laser intensity and initial electron density, the self-focusing process occurs in a temperature range which reaches its maximum at turning point temperature. However, the laser beam is converged in a narrow range for various amounts of initial electron density. It is indicated that the σ2 parameter and its sign can affect the self-focusing process for different values of laser intensity, initial temperature, and initial density. Finally, it is found that although the electron density ramp-down diverges the laser beam, electron density ramp-up improves the self-focusing process.
Hydrodynamic focusing investigation in a micro-flow cytometer.
Yang, An-Shik; Hsieh, Wen-Hsin
2007-04-01
Hydrodynamic focusing behavior is characterized by two fluids coflowing at different velocities inside a micro-flow cytometer. In this study, a two-fluid model has been established to describe the flow transport behavior and interaction of sample and sheath fluids. The analysis treats the sample and sheath fluids as two-dimensional, laminar, incompressible, and isothermal. The theoretical model comprises two groups of transient conservation equations of mass and momentum with consideration of the interfacial momentum exchange. The governing equations are solved numerically through an iterative SIMPLEC algorithm to determine the flow properties. Since the ratio of the sheath velocity to the sample velocity varies from 5 to 70, the predicted focusing width and length are in good agreement with the experimental data in the literature. In addition, the present study explored the hydrodynamic focusing flowfield as well as the pressure drop across a micro-flow cytometer and the time needed for the completion of one focusing event in detail. To enhance the understanding of hydrodynamic focusing in the design of cytometers, ten numerical experiments were conducted to examine the effects of the inner nozzle length, inner nozzle exit width, inner nozzle shape, and fluid properties on the width of the focused sample stream.
Lifelong Learning and Leadership. IDRA Focus.
ERIC Educational Resources Information Center
IDRA Newsletter, 1996
1996-01-01
This theme issue focuses on programs that promote lifelong learning through literacy education, parent empowerment, or parent leadership training. "Adult Literacy Outreach Innovations: Porque Significa Tanto" (Christie L. Goodman) describes a Texas outreach project that focuses on raising public awareness about adult education and…
Atmospheric Science Data Center
2016-02-17
... The first phase of the study in March will focus on Mexico City pollution outflow. The second phase during April and May will focus ... transcontinental/intercontinental scales and their impact on air quality and climate. A particular focus in this study is to quantify and ...
Process Security in Chemical Engineering Education
ERIC Educational Resources Information Center
Piluso, Cristina; Uygun, Korkut; Huang, Yinlun; Lou, Helen H.
2005-01-01
The threats of terrorism have greatly alerted the chemical process industries to assure plant security at all levels: infrastructure-improvement-focused physical security, information-protection-focused cyber security, and design-and-operation-improvement-focused process security. While developing effective plant security methods and technologies…
Giving High Schools an Occupational Focus.
ERIC Educational Resources Information Center
Grubb, W. Norton
1992-01-01
High school is an inescapably vocational institution whose occupational focus is largely hidden. Integration of vocational and academic education through academies, occupationally focused schools, and occupational clusters may eliminate "shopping mall" course selections, improve teaching of all subjects, enhance student engagement with learning,…
Restrike Particle Beam Experiments on a Dense Plasma Focus.
1981-11-30
particle beams generated in a plasma focus with the current flowing in the circuit just before the radial collapse of the pinch, IMB. The results show...the implications for the application of the plasma focus as an opening switch are discussed. (Author)
Experimental study of the focusing properties of a Gaussian Schell-model vortex beam.
Wang, Fei; Zhu, Shijun; Cai, Yangjian
2011-08-15
We carry out an experimental and theoretical study of the focusing properties of a Gaussian Schell-model (GSM) vortex beam. It is found that we can shape the beam profile of the focused GSM vortex beam by varying its initial spatial coherence width. Focused dark hollow, flat-topped, and Gaussian beam spots can be obtained in our experiment, which will be useful for trapping particles. The experimental results agree well with the theoretical results. © 2011 Optical Society of America
NASA Technical Reports Server (NTRS)
Yang, Ren; Feeback, Daniel L.; Wang, Wanjun
2004-01-01
This paper details a novel three-dimensional (3D) hydro-focusing micro cell sorter for micro flow cytometry applications. The unit was microfabricated by means of SU-8 3D lithography. The 3D microstructure for coaxial sheathing was designed, microfabricated, and tested. Three-dimensional hydro-focusing capability was demonstrated with an experiment to sort labeled tanned sheep erythrocytes (red blood cells). This polymer hydro-focusing microstructure is easily microfabricated and integrated with other polymer microfluidic structures.
The Role of Focused Echocardiography in Pediatric Intensive Care: A Critical Appraisal
Gaspar, Heloisa Amaral; Morhy, Samira Saady
2015-01-01
Echocardiography is a key tool for hemodynamic assessment in Intensive Care Units (ICU). Focused echocardiography performed by nonspecialist physicians has a limited scope, and the most relevant parameters assessed by focused echocardiography in Pediatric ICU are left ventricular systolic function, fluid responsiveness, cardiac tamponade and pulmonary hypertension. Proper ability building of pediatric emergency care physicians and intensivists to perform focused echocardiography is feasible and provides improved care of severely ill children and thus should be encouraged. PMID:26605333
High intensity focused ultrasound (HIFU) in tumor therapy.
Sequeiros, Roberto Blanco; Joronen, Kirsi; Komar, Gaber; Koskinen, Seppo K
HIFU (high intensity focused ultrasound) is a method in which high-frequency ultrasound is focused on a tissue in order to achieve a thermal effect and the subsequent percutaneously ablation, or tissue modulation. HIFU is non-invasive and results in an immediate tissue destruction effect corresponding to surgery, either percutaneously or through body cavities. HIFU can be utilized in the treatment of both benign and malignant tumors. In neurological diseases, focused HIFU can be used in the treatment of disorders of the basal ganglia.
2009-09-01
first statement of work is to determine if high intensity focused ultrasound ( HIFU ) increases the cellular uptake of AS-MDM2, AS-bcl-2 and AS-PKA...Drug Delivery in Prostate Tumor in vivo Using MR Guided Focused Ultrasound (MRg HIFU ). WC, IFMBE Proceedings 25: pp341-344, 2009 6...pharmaceutical agents in the treatment target. In the model system proposed, pulsed high intensity focused ultrasound ( HIFU ) is hypothesized to improve
Lerman, Gilad M; Levy, Uriel
2007-08-01
We study the tight-focusing properties of spatially variant vector optical fields with elliptical symmetry of linear polarization. We found the eccentricity of the incident polarized light to be an important parameter providing an additional degree of freedom assisting in controlling the field properties at the focus and allowing matching of the field distribution at the focus to the specific application. Applications of these space-variant polarized beams vary from lithography and optical storage to particle beam trapping and material processing.
Focusing geometry-induced size tailoring of silver nanoparticles obtained by laser ablation in water
NASA Astrophysics Data System (ADS)
Stasic, Jelena; Joksic, Gordana; Zivkovic, Ljiljana; Mihailescu, Ion N.; Ghica, Corneliu; Kuncser, Andrei; Trtica, Milan
2014-10-01
Silver nanoparticles were obtained by picosecond laser ablation in water at 1064 nm, using focusing geometry to design the particles’ size. The position of the target surface with respect to the focal point strongly influences the NPs’ size: above and in the focus it is up to 20 nm and below focus ≤ 150 nm. Generated particles have a spherical shape. The solutions were further employed on human cells and the tests showed a deteriorating effect on DNA.
Interference-free coherence dynamics of gas-phase molecules using spectral focusing.
Wrzesinski, Paul J; Roy, Sukesh; Gord, James R
2012-10-08
Spectral focusing using broadband femtosecond pulses to achieve highly selective measurements has been employed for numerous applications in spectroscopy and microspectroscopy. In this work we highlight the use of spectral focusing for selective excitation and detection of gas-phase species. Furthermore, we demonstrate that spectral focusing, coupled with time-resolved measurements based upon probe delay, allows the observation of interference-free coherence dynamics of multiple molecules and gas-phase temperature making this technique ideal for gas-phase measurements of reacting flows and combustion processes.
1984-03-01
POWERED PLASMA FOCUS Contract No. AFOSR-83-0145 PROGRESS REPORT For the Period April 1, 1983 through March 31, 1984 Submitted to Air Force Office of...AND ACCELERATION USING LINEAR ELECTRON BEAMS AND A PULSE POWERED PLASMA FOCUS Contract No. AFOSR-83-0145 PROGRESS REPORT For the Period April 1, 1983...Acceleration Using Linear Electron Beams and a Pulse Powered Plasma Focus " 01 €,G APRIL 1, 1983 THROUGH MRCH 31, 1984 A. Collective Acceleration and Related
An Experimental Study of the Plasma Focus Device as a Charged Particle Accelerator
1988-11-01
The dense plasma focus has been investigated at many laboratories as a possible fusion device. Typical plasma parameters for this device are electron...temperatures of 1 keV, densities of 10 to the 19th power per cc, and confinement times of 100 ns. Characteristic of the plasma focus discharge are...neutrons. The emphasis of this work is to investigate the electron and ion emission from the plasma focus and the development of appropriate diagnostics to
Smith, Valerie; Daly, Deirdre; Lundgren, Ingela; Eri, Tine; Benstoem, Carina; Devane, Declan
2014-04-01
research on intrapartum interventions in maternity care has focused traditionally on the identification of risk factors' and on the reduction of adverse outcomes with less attention given to the measurement of factors that contribute to well-being and positive health outcomes. We conducted a systematic review of reviews to determine the type and number of salutogenically-focused reported outcomes in current maternity care intrapartum intervention-based research. For the conduct of this review, we interpreted salutogenic outcomes as those relating to optimum and/or positive maternal and neonatal health and well-being. to identify salutogenically-focused outcomes reported in systematic reviews of randomised trials of intrapartum interventions. we searched Issue 9 (September) 2011 of the Cochrane Database of Systematic Reviews for all reviews of intrapartum interventions published by the Cochrane Pregnancy and Childbirth Group using the group filter "hm-preg". Systematic reviews of randomised trials of intrapartum interventions were eligible for inclusion. We excluded protocols for systematic reviews and systematic reviews that had been withdrawn. Outcome data were extracted independently from each included review by at least two review authors. Unique lists of salutogenically and non-salutogenically focused outcomes were established. 16 salutogenically-focused outcome categories were identified in 102 included reviews. Maternal satisfaction and breast feeding were reported most frequently. 49 non-salutogenically-focused outcome categories were identified in the 102 included reviews. Measures of neonatal morbidity were reported most frequently. there is an absence of salutogenically-focused outcomes reported in intrapartum intervention-based research. We recommend the development of a core outcome data set of salutogenically-focused outcomes for intrapartum research. © 2013 Published by Elsevier Ltd.
Cost-effectiveness of focused ultrasound, radiosurgery, and DBS for essential tremor.
Ravikumar, Vinod K; Parker, Jonathon J; Hornbeck, Traci S; Santini, Veronica E; Pauly, Kim Butts; Wintermark, Max; Ghanouni, Pejman; Stein, Sherman C; Halpern, Casey H
2017-08-01
Essential tremor remains a very common yet medically refractory condition. A recent phase 3 study demonstrated that magnetic resonance-guided focused ultrasound thalamotomy significantly improved upper limb tremor. The objectives of this study were to assess this novel therapy's cost-effectiveness compared with existing procedural options. Literature searches of magnetic resonance-guided focused ultrasound thalamotomy, DBS, and stereotactic radiosurgery for essential tremor were performed. Pre- and postoperative tremor-related disability scores were collected from 32 studies involving 83 magnetic resonance-guided focused ultrasound thalamotomies, 615 DBSs, and 260 stereotactic radiosurgery cases. Utility, defined as quality of life and derived from percent change in functional disability, was calculated; Medicare reimbursement was employed as a proxy for societal cost. Medicare reimbursement rates are not established for magnetic resonance-guided focused ultrasound thalamotomy for essential tremor; therefore, reimbursements were estimated to be approximately equivalent to stereotactic radiosurgery to assess a cost threshold. A decision analysis model was constructed to examine the most cost-effective option for essential tremor, implementing meta-analytic techniques. Magnetic resonance-guided focused ultrasound thalamotomy resulted in significantly higher utility scores compared with DBS (P < 0.001) or stereotactic radiosurgery (P < 0.001). Projected costs of magnetic resonance-guided focused ultrasound thalamotomy were significantly less than DBS (P < 0.001), but not significantly different from radiosurgery. Magnetic resonance-guided focused ultrasound thalamotomy is cost-effective for tremor compared with DBS and stereotactic radiosurgery and more effective than both. Even if longer follow-up finds changes in effectiveness or costs, focused ultrasound thalamotomy will likely remain competitive with both alternatives. © 2017 International Parkinson and Movement Disorder Society. © 2017 International Parkinson and Movement Disorder Society.
Worker, workplace or families: What influences family focused practices in adult mental health?
Maybery, D; Goodyear, M; Reupert, A E; Grant, A
2016-04-01
WHAT IS KNOWN ON THE SUBJECT?: Family focused practice leads to positive outcomes for parents and children. There are barriers and enablers for practitioners being family focused. WHAT THIS PAPER ADDS TO EXISTING KNOWLEDGE?: Worker skill, knowledge and confidence about family work are the most important factors associated with family focused practices. WHAT ARE THE IMPLICATIONS FOR PRACTICE?: Mental health nurses require specific skill training in family focused practices, time to engage with clients on parenting issues and that there are adequate services to refer family members to. Introduction Family focused practice is thought to lead to positive outcomes for all family members. However, there are multiple barriers and enablers in adult mental health services to practitioners undertaking these actions. Aim The aim of this study was to examine the relative importance of worker, workforce and family factors to predict family focused practices (FFPs) in adult mental health services. Method Three hundred and seven adult mental health workers completed a 45 items family focused practice measure of 16 family focused practices. Thesis It was found that worker skill and knowledge about family work and an ability to assess the degree of parental insight into the child's connections to other family members and the community were important predictors of FFP, along with the closely related-worker confidence. While aspects of the worker, workplace and family each contribute to FFPs, this study highlighted the importance of worker skill, knowledge and confidence as central issues for adult mental health workers. Implications for practice Study implications include the need for training in specific FFPs, the provision of time to engage with clients on parenting issues and the need 5 to ensure that there are adequate services for workers to refer family members to. © 2016 John Wiley & Sons Ltd.
Gaston-Johansson, Fannie; Hill-Briggs, Felicia; Oguntomilade, Lola; Bradley, Vanessa; Mason, Phyllis
2007-12-01
The existence of racial and ethnic disparities in healthcare in the United States is well recognized. However, often overlooked in the planning and design of initiatives to address those disparities are the patient perspectives regarding the issues of racial and ethnic disparities that directly affect them. The objective of this study was to identify the patient priorities and to provide recommendations for action to improve minority health-care quality. A secondary objective was the qualitative analysis of the Institute of Medicine (IOM) focus group data. Six focus groups were conducted with nine participants in each. These included an African-American focus group in Washington, D.C., an African-American focus group in Los Angeles, an Asian focus group in Los Angeles, an Hispanic focus group in Washington, D.C., an Hispanic focus group in Los Angeles, and a Native American focus group in Albuquerque, NM. The barriers and priorities for action included difficulty in making informed choices when identifying and selecting providers, poor service delivery from medical office staff, the inefficiency of medical visits, provider communication and cultural competence barriers, and stressful treatment settings. Patient recommendations targeted provision of tools to empower patients throughout the process of care, provider and staff training in communication and cultural competence, alternate models of service delivery, and accessible mechanisms for evaluation and oversight. This study concluded that patient-identified priorities and recommendations warranted modification of current explanatory models for minority health-care quality and the provision of greater clarity regarding directions for policy and behavioral initiatives and criteria for performance evaluation be advanced.
Monte Carlo evaluation of magnetically focused proton beams for radiosurgery
NASA Astrophysics Data System (ADS)
McAuley, Grant A.; Heczko, Sarah L.; Nguyen, Theodore T.; Slater, James M.; Slater, Jerry D.; Wroe, Andrew J.
2018-03-01
The purpose of this project is to investigate the advantages in dose distribution and delivery of proton beams focused by a triplet of quadrupole magnets in the context of potential radiosurgery treatments. Monte Carlo simulations were performed using various configurations of three quadrupole magnets located immediately upstream of a water phantom. Magnet parameters were selected to match what can be commercially manufactured as assemblies of rare-earth permanent magnetic materials. Focused unmodulated proton beams with a range of ~10 cm in water were target matched with passive collimated beams (the current beam delivery method for proton radiosurgery) and properties of transverse dose, depth dose and volumetric dose distributions were compared. Magnetically focused beams delivered beam spots of low eccentricity to Bragg peak depth with full widths at the 90% reference dose contour from ~2.5 to 5 mm. When focused initial beam diameters were larger than matching unfocused beams (10 of 11 cases) the focused beams showed 16%–83% larger peak-to-entrance dose ratios and 1.3 to 3.4-fold increases in dose delivery efficiency. Peak-to-entrance and efficiency benefits tended to increase with larger magnet gradients and larger initial diameter focused beams. Finally, it was observed that focusing tended to shift dose in the water phantom volume from the 80%–20% dose range to below 20% of reference dose, compared to unfocused beams. We conclude that focusing proton beams immediately upstream from tissue entry using permanent magnet assemblies can produce beams with larger peak-to-entrance dose ratios and increased dose delivery efficiencies. Such beams could potentially be used in the clinic to irradiate small-field radiosurgical targets with fewer beams, lower entrance dose and shorter treatment times.
Davis, Esther L; McCaffery, Kirsten; Mullan, Barbara; Juraskova, Ilona
2015-12-01
Decision aids (DAs) are non-directive communication tools that help patients make value-consistent health-care decisions. However, most DAs have been developed without an explicit theoretical framework, resulting in a lack of understanding of how DAs achieve outcomes. To investigate the effect of promoting affective vs. deliberative processing on DA effectiveness based on dual-process theory. One hundred and forty-eight female university students participated in a randomized controlled experiment with three conditions: emotion-focused, information-focused and control. Preference-value consistency, knowledge, decisional conflict and satisfaction were compared across the conditions using planned contrast analyses. The intervention comprised two different DAs and instructional manipulations. The emotion-focused condition received a modified DA with affective content and instructions to induce an affective reaction. The information-focused and control conditions received the same DA without the affective content. The information-focused condition received additional instructions to induce deliberative processing. Controlling for the experiment-wise error rate at P < 0.017, the emotion-focused and information-focused conditions had significantly higher decisional satisfaction than the control condition (P < 0.001). The emotion-focused condition did not demonstrate preference-value consistency. There were no significant differences for decisional conflict and knowledge. Results suggest that the promotion of affective processing may hinder value-consistent decision making, while deliberative processing may enhance decisional satisfaction. This investigation of the effect of affective and deliberative processes in DA-supported decision making has implications for the design and use of DAs. DA effectiveness may be enhanced by incorporating a simple instruction to focus on the details of the information. © 2014 John Wiley & Sons Ltd.
Bornas, Xavier; Tortella-Feliu, Miquel; Balle, Maria; Llabrés, Jordi
2013-01-01
The cognitive regulation of emotions is important for human adaptation. Self-focused emotion regulation (ER) strategies have been linked to the development and persistence of anxiety and depression. A vast array of research has provided valuable knowledge about the neural correlates of the use of specific self-focused ER strategies; however, the resting neural correlates of cognitive ER styles, which reflect an individual's disposition to engage in different forms of ER in order to manage distress, are largely unknown. In this study, associations between theoretically negative ER style (self-focused or not) and the complexity (fractal dimension, FD) of the resting EEG at frontal, central, parietal, and occipital regions were investigated in 58 healthy volunteers. The Cognitive Emotion Regulation Questionnaire was used as the self-report measure of ER style. Results showed that a diminished FD over the scalp significantly correlated with self-focused ER style scores, even after controlling for negative affect, which has been also considered to influence the use of ER strategies. The lower the EEG FD, the higher were the self-focused ER style scores. Correlational analyses of specific self-focused ER strategies showed that self-blaming and rumination were negatively associated with diminished FD of the EEG, but catastrophizing and blaming others were not. No significant correlations were found for ER strategies more focused on situation or others. Results are discussed within the self-organized criticality theory of brain dynamics: The diminished FD of the EEG may reflect a disposition to engage in self-focused ER strategies as people prone to ruminate and self-blame show a less complex resting EEG activity, which may make it more difficult for them to exit their negative emotional state.
Parent-child health- and weight-focused conversations: Who is saying what and to whom?
Winkler, Megan R; Berge, Jerica M; Larson, Nicole; Loth, Katie A; Wall, Melanie; Neumark-Sztainer, Dianne
2018-07-01
The purpose of this study was to examine the prevalence of health-focused (healthy eating, physical activity) and weight-focused (weight, dieting) parent-child conversations, and to understand who is talking and who is listening, by exploring the associations these conversations have with parent and child characteristics. The study population included 546 parents (age 27-36 years) who participated in Project EAT (Eating and Activity in Teens and Young Adults)-IV (2015-2016) and had a child aged 2-17 years. Cross-sectional prevalence ratios were calculated to identify associations between parent and child characteristics and the parent-child conversations. Conversations about healthy eating (82%) and physical activity (75%) were more prevalent than those about the child's weight (30%), and dieting (25%). In adjusted models, parents meeting physical activity recommendations had a higher prevalence of health-focused conversations (healthy eating PR = 1.10, 95% CI = 1.01, 1.20; physical activity PR = 1.12, 95% CI = 1.02, 1.24); whereas, weight-focused conversations were more common among parents who had recently dieted and perceived their child to be overweight. Health-focused and weight-focused conversations were highly common among the oldest children aged 9-17 years (health-focused = 90-93% and weight-focused = 42-53%); though, a substantial prevalence of health- and weight-focused conversations (>50% and ≥10%, respectively) also occurred with the youngest children (2-4 years). Findings suggest that parent-child health- and weight-focused conversations are common and that characteristics, including child's age and parents' physical activity, dieting, and perceptions of child weight, may be useful to consider in public health messaging, interventions, and family education that address parent-child communication. Copyright © 2018 Elsevier Ltd. All rights reserved.
Redundancy Technology With A Focused Ion Beam
NASA Astrophysics Data System (ADS)
Komano, Haruki; Hashimoto, Kazuhiko; Takigawa, Tadahiro
1989-08-01
Fuse cutting with a focused ion beam to activate redundancy circuits is proposed. In order to verify its potential usefulness, experiments have been performed. Fuse-cutting time was evaluated using aluminum fuses with a thin passivation layer, which are difficult to cut by conventional laser-beam technology due to the material's high reflectivity. The fuse width and thickness were 2 and 0.8 μm, respectively. The fuse was cut in 5 seconds with a 30 keV focused ion beam of 0.3 A/cm2 current density. Since the fuses used in DRAMs will be smaller, their cutting time will become shorter by scanning an ion beam on narrower areas. Moreover, it can be shortened by increasing current density. Fuses for redundancy technology in 256 k CMOS SRAMs were cut with a focused ion beam. The operation of the memories was checked with a memory tester. It was confirmed that memories which had failure cells operated normally after focused-ion-beam fuse-cutting. Focused ion beam irradiation effects upon a device have been studied. When a 30 keV gallium focused ion beam was irradiated near the gate of MOSFETs, a threshold voltage shift was not observed at an ion dose of 0.3 C/cm2 which corresponded to the ion dose in cutting a fuse. However, when irradiated on the gate, a threshold voltage shift was observed at ion doses of more than 8 x 10-4 C/cm2. The voltage shift was caused by the charge of ions within the passivation layer. It is necessary at least not to irradiate a focused ion beam on a device in cutting fuses. It is concluded that the focused-ion-beam method will be advantageous for future redundancy technology application.
Regulatory focus and adherence to self-care behaviors among adults with type 2 diabetes.
Avraham, Rinat; Van Dijk, Dina; Simon-Tuval, Tzahit
2016-09-01
The aims of this study were, first, to test the association between regulatory focus of adults with type 2 diabetes and their adherence to two types of self-care behaviors - lifestyle change (e.g. physical activity and diet) and medical care regimens (blood-glucose monitoring, foot care and medication usage). Second, to explore whether a fit between the message framing and patients' regulatory focus would improve their intentions to adhere specifically when the type of behavior fits the patients' regulatory focus as well. A cross-sectional study was conducted among 130 adults with type 2 diabetes who were hospitalized in an academic medical center. The patients completed a set of questionnaires that included their diabetes self-care activities, regulatory focus, self-esteem and demographic, socioeconomic and clinical data. In addition, participants were exposed to either a gain-framed or a loss-framed message, and were then asked to indicate their intention to improve adherence to self-care behaviors. A multivariable linear regression model revealed that promoters reported higher adherence to lifestyle change behaviors than preventers did (B = .60, p = .028). However, no effect of regulatory focus on adherence to medical care regimens was found (B = .46, p = .114). In addition, preventers reported higher intentions to adhere to medical care behaviors when the message framing was congruent with prevention focus (B = 1.16, p = .023). However, promoters did not report higher intentions to adhere to lifestyle behaviors when the message framing was congruent with promotion focus (B = -.16, p = .765). These findings justify the need to develop tailor-made interventions that are adjusted to both patients' regulatory focus and type of health behavior.
Improving posture-motor dual-task with a supraposture-focus strategy in young and elderly adults
Yu, Shu-Han
2017-01-01
In a postural-suprapostural task, appropriate prioritization is necessary to achieve task goals and maintain postural stability. A “posture-first” principle is typically favored by elderly people in order to secure stance stability, but this comes at the cost of reduced suprapostural performance. Using a postural-suprapostural task with a motor suprapostural goal, this study investigated differences between young and older adults in dual-task cost across varying task prioritization paradigms. Eighteen healthy young (mean age: 24.8 ± 5.2 years) and 18 older (mean age: 68.8 ± 3.7 years) adults executed a designated force-matching task from a stabilometer board using either a stabilometer stance (posture-focus strategy) or force-matching (supraposture-focus strategy) as the primary task. The dual-task effect (DTE: % change in dual-task condition; positive value: dual-task benefit, negative value: dual-task cost) of force-matching error and reaction time (RT), posture error, and approximate entropy (ApEn) of stabilometer movement were measured. When using the supraposture-focus strategy, young adults exhibited larger DTE values in each behavioral parameter than when using the posture-focus strategy. The older adults using the supraposture-focus strategy also attained larger DTE values for posture error, stabilometer movement ApEn, and force-matching error than when using the posture-focus strategy. These results suggest that the supraposture-focus strategy exerted an increased dual-task benefit for posture-motor dual-tasking in both healthy young and elderly adults. The present findings imply that the older adults should make use of the supraposture-focus strategy for fall prevention during dual-task execution. PMID:28151943
Improving posture-motor dual-task with a supraposture-focus strategy in young and elderly adults.
Yu, Shu-Han; Huang, Cheng-Ya
2017-01-01
In a postural-suprapostural task, appropriate prioritization is necessary to achieve task goals and maintain postural stability. A "posture-first" principle is typically favored by elderly people in order to secure stance stability, but this comes at the cost of reduced suprapostural performance. Using a postural-suprapostural task with a motor suprapostural goal, this study investigated differences between young and older adults in dual-task cost across varying task prioritization paradigms. Eighteen healthy young (mean age: 24.8 ± 5.2 years) and 18 older (mean age: 68.8 ± 3.7 years) adults executed a designated force-matching task from a stabilometer board using either a stabilometer stance (posture-focus strategy) or force-matching (supraposture-focus strategy) as the primary task. The dual-task effect (DTE: % change in dual-task condition; positive value: dual-task benefit, negative value: dual-task cost) of force-matching error and reaction time (RT), posture error, and approximate entropy (ApEn) of stabilometer movement were measured. When using the supraposture-focus strategy, young adults exhibited larger DTE values in each behavioral parameter than when using the posture-focus strategy. The older adults using the supraposture-focus strategy also attained larger DTE values for posture error, stabilometer movement ApEn, and force-matching error than when using the posture-focus strategy. These results suggest that the supraposture-focus strategy exerted an increased dual-task benefit for posture-motor dual-tasking in both healthy young and elderly adults. The present findings imply that the older adults should make use of the supraposture-focus strategy for fall prevention during dual-task execution.
Shrestha, T
2013-09-01
Nursing requires high self-esteem and effective coping strategies for the quality of health services that they deliver. Self -esteem and stress coping mechanism developed during education period is foundation for professional practice. So, this study was conducted to identify self-esteem, coping activities, and their relationship. Descriptive cross sectional study was conducted among 287 PCL nursing students currently studying in different level in nursing campuses of the Institute of Medicine during June and July 2013. Self administered semi structured questionnaire and rating scales were used for the data collection. Findings showed that 21 (7.31%), 194 (67.5%), and 67 (23.34%), students had have very high, high and moderate, self-esteem and only five (1.74%) have low self-esteem.The difference in self-esteem level was insignificant with the level of the students. Students most frequently used problem focused (3.36±0.54) followed by emotion focused (3.04±0.45) and avoidance coping activities (2.91±0.63). The relationship of use of coping activities and level of students was statistically insignificant. Self-esteem level had positive relation with problem focused and emotion focused coping activities (Pearson r: 0.114 and 0.118), though the correlation was significant with emotion focused coping activities only. Bicytopenia and pancytopenia were seen in two cases each of myelodysplastic syndrome. Chronic myeloid leukemia and Non-Hodgkin lymphoma showed anemia and pancytopenia respectively. Majority of PCL nursing students have high level of self-esteem. They used problem focused coping activities most however, use of it decreased with increased level of students. Students with high self -esteem used problem focused followed by emotion focused coping activities. Students should be encouraged to use problem focused coping activities.
Motivational predictors of coping with academic examination.
Doron, Julie; Stephan, Yannick; Maiano, Christophe; Le Scanff, Christine
2011-01-01
The present study focused on the motivational predictors of coping with academic examination through the test of the contribution of self-determination for academic studies and achievement goals. Coping strategies, academic motivation and achievement goals were assessed among 199 undergraduate students. Regression analysis revealed that problem-focused coping is positively predicted by identified regulation and negatively by amotivation, whereas emotion-focused coping is positively predicted by introjected regulation and amotivation. Mastery approach goals contributed positively to problem-focused coping. Identified regulation and mastery approach goals made a unique positive contribution to problem-focused coping, and amotivation was negatively related. Students' coping actions may vary according to both the reasons why they engage in academic studies and the goals they pursue in this setting.
Using Sociograms to Enhance Power and Voice in Focus Groups.
Baiardi, Janet M; Gultekin, Laura; Brush, Barbara L
2015-01-01
To discuss the use of sociograms in our focus groups with homeless sheltered mothers and to assess facilitator influence and the distribution of power influence. An exploratory, descriptive qualitative design that utilizes both focus groups and sociograms. Two focus groups were conducted in December 2009 (N = 7) and January 2010 (N = 4). Data analysis included a content analysis and a process analysis using sociograms to graphically represent group participant dynamics. Use of the sociogram provided a means to assess the influence of the facilitator as well as quantify the degree to which group participants' voices are included. Using sociograms provides a viable mechanism to complement content analysis and increase the methodological rigor of focus groups in health care research. © 2015 Wiley Periodicals, Inc.
The development of a physiotherapy continence promotion program using a customer focus.
Chiarelli, Pauline; Cockburn, Jill
1999-01-01
Health promotion programs provide information, education for health and opportunity for the development of the skills that people need to make healthy choices. The current climate of health care practice also directs its focus to the needs and wants of the health care consumers. This entails active input from the target group. The present study used focus groups in an attempt to ensure input from women in early postpartum into the development of a postpartum continence promotion program. The focus groups revealed anomalies in women's perceived susceptibility to, and knowledge about, urinary incontinence and pelvic floor exercises, while highlighting other areas of need. Focus groups proved an invaluable tool in the development of a more effective physiotherapy continence promotion program.
Radar research at University of Oklahoma (Conference Presentation)
NASA Astrophysics Data System (ADS)
Zhang, Yan R.; Weber, Mark E.
2017-05-01
This abstract is for the academic institution profiles session This presentation will focus on radar research programs at the University of Oklahoma, the radar research in OU has more than 50 years history of collaboration with NOAA, and has been through tremendous growth since early 2000. Before 2010, the focus was weather radar and weather surveillance, and since the Defense, Security and Intelligence (DSI) initiative in 2011, there have many new efforts on the defense and military radar applications. This presentation will focus on the following information: (1) The history, facilities and instrumentations of Advanced Radar Research Center, (2) Focus area of polarimetric phased array systems, (3) Focus area of airborne and spaceborne radars, (4) Intelligent radar information processing, (5) Innovative antenna and components.
A multi-focus image fusion method via region mosaicking on Laplacian pyramids
Kou, Liang; Zhang, Liguo; Sun, Jianguo; Han, Qilong; Jin, Zilong
2018-01-01
In this paper, a method named Region Mosaicking on Laplacian Pyramids (RMLP) is proposed to fuse multi-focus images that is captured by microscope. First, the Sum-Modified-Laplacian is applied to measure the focus of multi-focus images. Then the density-based region growing algorithm is utilized to segment the focused region mask of each image. Finally, the mask is decomposed into a mask pyramid to supervise region mosaicking on a Laplacian pyramid. The region level pyramid keeps more original information than the pixel level. The experiment results show that RMLP has best performance in quantitative comparison with other methods. In addition, RMLP is insensitive to noise and can reduces the color distortion of the fused images on two datasets. PMID:29771912
[A focused sound field measurement system by LabVIEW].
Jiang, Zhan; Bai, Jingfeng; Yu, Ying
2014-05-01
In this paper, according to the requirement of the focused sound field measurement, a focused sound field measurement system was established based on the LabVIEW virtual instrument platform. The system can automatically search the focus position of the sound field, and adjust the scanning path according to the size of the focal region. Three-dimensional sound field scanning time reduced from 888 hours in uniform step to 9.25 hours in variable step. The efficiency of the focused sound field measurement was improved. There is a certain deviation between measurement results and theoretical calculation results. Focal plane--6 dB width difference rate was 3.691%, the beam axis--6 dB length differences rate was 12.937%.
[Focused ultrasound therapy: current status and potential applications in neurosurgery].
Dervishi, E; Aubry, J-F; Delattre, J-Y; Boch, A-L
2013-12-01
High Intensity Focused Ultrasound (HIFU) therapy is an innovative approach for tissue ablation, based on high intensity focused ultrasound beams. At the focus, HIFU induces a temperature elevation and the tissue can be thermally destroyed. In fact, this approach has been tested in a number of clinical studies for the treatment of several tumors, primarily the prostate, uterine, breast, bone, liver, kidney and pancreas. For transcranial brain therapy, the skull bone is a major limitation, however, new adaptive techniques of phase correction for focusing ultrasound through the skull have recently been implemented by research systems, paving the way for HIFU therapy to become an interesting alternative to brain surgery and radiotherapy. Copyright © 2013 Elsevier Masson SAS. All rights reserved.