Sample records for foley catheter balloon

  1. Intrauterine Inflated Foley's Catheter Balloon in the Management of Abnormally Invasive Placenta Previa: A Case-Control Study.

    PubMed

    Thabet, Mahmoud; Abdelhafez, Mohamed Sayed; Fyala, Emad Ahmed

    2018-06-01

    To describe the use of intrauterine inflated Foley's catheter balloon for control of postpartum hemorrhage (PPH) during cesarean section (CS) in cases of abnormally invasive placenta previa aiming to preserve the uterus. Retrospective case-control study of the data of women who underwent elective CS on abnormally adherent placenta previa was carried out. Women in whom inflated Foley's catheter balloon was used for control of PPH during CS ( n  = 40) were compared with a control group of women who underwent elective CS by the same technique but without use of intrauterine catheter balloon ( n  = 38). Use of intrauterine inflated Foley's catheter balloon significantly reduced the estimated amount of blood loss ( P  = 0.008), amounts of crystalloids, colloids and packed red blood cells transfusion ( P  = 0.025, 0.017 and 0.022, respectively), and the need for bilateral internal iliac artery (IIA) ligation ( P  = 0.016). No significant difference was observed between both groups regarding the use of massive transfusion protocol, performing cesarean hysterectomy, relaparotomy, and admission to the intensive care unit. Application of an intrauterine inflated Foley's catheter balloon during CS in cases of morbidly adherent placenta previa helps to control PPH with preservation of the uterus and decreases the need for the invasive IIA ligation.

  2. Improved mortality from penetrating neck and maxillofacial trauma using Foley catheter balloon tamponade in combat.

    PubMed

    Weppner, Justin

    2013-08-01

    The military medical community has promoted use of Foley catheter balloon tamponade in the initial management of vascular injury owing to neck or maxillofacial trauma. The aim of the study was to compare outcomes with Foley catheter tamponade with those obtained with traditional use of external pressure. This retrospective cohort study evaluated all cases of persistent bleeding caused by penetrating neck or maxillofacial trauma received at one forward aid station between December 2009 and October 2011. Cohorts included those who were treated with Foley catheter tamponade and those managed with external pressure. Which treatment option was applied depended solely on the availability of Foley catheters at the time. The effectiveness of each technique in controlling initial and delayed hemorrhage is described, and the impact on mortality is analyzed using the Student's t test and Fisher's exact test. Seventy-seven subjects met the inclusion criteria with 42 subjects in the Foley group and 35 subjects in the external pressure group. A statistically significant difference was found between the groups regarding delayed failure, experienced by three patients (7%) in the Foley group and nine patients (26%) in the external pressure group (p < 0.05). The difference in mortality, 5% (two patients) in the Foley tamponade group and 23% (eight patients) in the external pressure group, was statistically significant (p < 0.05). For penetrating neck and maxillofacial injuries in a combat environment, Foley catheter balloon tamponade significantly reduced mortality when compared with direct pressure techniques through its effect on preventing delayed bleeding.

  3. Foley catheter balloon endometrial ablation: successful treatment of three cases.

    PubMed

    Api, Murat; Api, Olus

    2012-03-01

    Endometrial ablation is one of the most effective methods for treatment of dysfunctional uterine bleeding (DUB). Balloon devices with circulating hot water inside or electrodes on the outer surface and radiofrequency-induced thermal destructors are the most recently introduced available tools for endometrial ablation. All of these methods are effective and simple but expensive technologies. The aim of this brief report is to evaluate the effectiveness and safety of a new, simple and money-saving procedure, namely foley catheter balloon endometrial ablation (FCBEA), for treatment of DUB. We present our experience with FCBEA performed on 3 women with severe meno-metrorrhagia unresponsive to medical therapy. There were no procedure-related complications with achievement of complete amenorrhea for a 19 months follow-up period. Although FCBA has yielded encouraging results, there exists a need for further investigation and validation on larger groups, before its universal application.

  4. A fragment of Foley catheter balloon as a cause of Bladder stone in woman

    PubMed Central

    Aziz, El Majdoub; Amrani, Mouad; Abdelhak, Khallouk; Hassan, Farih Moulay

    2015-01-01

    Urinary bladder calculi are rarely seen in women and any history of previous pelvic surgery must, therefore, raise suspicion of an iatrogenic etiology. According to the literature, fewer than 2% of all bladder calculi occur in female subjects and, thus, their presence should provoke careful assessment of the etiology. We report one case of a fragment of Foley catheter balloon as a cause of Bladder stone in 28 years old woman. Weanalyzed the diagnosis, aspect and therapeutic management of this case which is the first described in literature to our knowledge. PMID:26587134

  5. Missed signs of autonomic dysreflexia in a tetraplegic patient after incorrect placement of urethral Foley catheter: a case report.

    PubMed

    Vaidyanathan, Subramanian; Soni, Bakul M; Oo, Tun; Hughes, Peter L; Singh, Gurpreet

    2014-01-01

    Autonomic dysreflexia is poorly recognised outside of spinal cord injury centres, and may result in adverse outcomes including mortality from delayed diagnosis and treatment. We present a spinal cord injury patient, who developed autonomic dysreflexia following incorrect placement of urethral Foley catheter. Health professionals failed to recognise signs and symptoms of autonomic dysreflexia as well as its significance in this tetraplegic patient. A tetraplegic patient started sweating profusely following insertion of a Foley catheter per urethra. The catheter was draining urine; there was no bypassing, no bleeding per urethra, and no haematuria. Patient's wife, who had been looking after her tetraplegic husband for more than forty years, told the health professionals that the catheter might have been placed incorrectly but her concerns were ignored. Ultrasound scan of urinary tract revealed no urinary calculi, no hydronephrosis. The balloon of Foley catheter was not seen in urinary bladder but this finding was not recognised by radiologist and spinal cord physician. Patient continued to sweat profusely; therefore, CT of pelvis was performed, but there was a delay of ten days. CT revealed the balloon of Foley catheter in the over-stretched prostate-membranous urethra; the tip of catheter was not located within the urinary bladder but was lying distal to bladder neck. Flexible cystoscopy was performed and Foley catheter was inserted into the bladder over a guide wire. The intensity of sweating decreased; noxious stimuli arising from traumatised urethra might take a long while to settle. Inserting a catheter in a tetraplegic patient should be carried out by a senior health professional, who is familiar with spasm of bladder neck which occurs frequently in tetraplegic patients. Facilities for urgent CT scan should be available to check the position of Foley catheter in spinal cord injury patients when a patient manifests signs and symptoms of autonomic dysreflexia

  6. A prospective randomized trial comparing Foley catheter, oxytocin, and combination Foley catheter-oxytocin for labour induction with unfavourable cervix.

    PubMed

    El Khouly, Nabih I

    2017-04-01

    The purpose of this study was to evaluate the effectiveness and safety of transcervical Foley catheter with and without oxytocin versus oxytocin alone for labour induction with unfavourable cervix. This trial enrolled 108 women with singleton pregnancies presented for labour induction with unfavourable cervix. Patients were randomly assigned to receive Foley catheter alone (I), Foley catheter plus oxytocin (II) or oxytocin alone (III). Outcomes were analysed in terms of success of induction, induction delivery interval, route of delivery, dose and duration of oxytocin, and complications. Successful normal vaginal delivery was more common in group I (p = .02) compared to group III. Induction delivery time was statistically shorter in group II and group III (p < .001). Patients in group I required significantly less oxytocin dose and duration (p < .001). This led to our conclusion that induction of labour with Foley catheter without oxytocin increases success rate of normal vaginal delivery; however, it has a longer induction delivery interval with similar complications.

  7. Percutaneous Management of Postoperative Duodenal Stump Leakage with Foley Catheter

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Oh, Jung Suk, E-mail: oj-cumc@daum.net; Lee, Hae Giu, E-mail: hgleehfh@catholic.ac.kr; Chun, Ho Jong

    2013-10-15

    Purpose: This study was designed to evaluate retrospectively the safety and efficacy of the percutaneous management of duodenal stump leakage with a Foley catheter after subtotal gastrectomy. Methods: Ten consecutive patients (M:F = 9:1, median age: 64 years) were included in this retrospective study. The duodenal stump leakages were diagnosed in all the patients within a median of 10 days (range, 6-20). At first, the patients underwent percutaneous drainage on the day of or the day after confirmation of the presence of duodenal stump leakage, and then the Foley catheters were replaced at a median of 9 days (range, 6-38)more » after the percutaneous drainage. Results: Foley catheters were placed successfully in the duodenal lumen of all the patients under a fluoroscopic guide. No complication was observed during and after the procedures in all the patients. All of the patients started a regular diet 1 day after the Foley catheter placement. The patients were discharged at a median of 7 days (range, 5-14) after the Foley catheter placement. The catheters were removed in an outpatient clinic 10-58 days (median, 28) after the Foley catheter placement. Conclusions: Fluoroscopy-guided percutaneous Foley catheter placement may be a safe and effective treatment option for postoperative duodenal stump leakage and may allow for shorter hospital stays, earlier oral intake, and more effective control of leakage sites.« less

  8. Balloon-Inflated Catheters for Enteral Feeding: a Word of Caution.

    PubMed

    Dash, Nihar Ranjan; Singh, Anand Narayan; Kilambi, Ragini

    2018-02-01

    Catheters with inflatable balloons such as a Foley catheter may be used for feeding gastrostomy/jejunostomy. The incorrect or improper use of these catheters can have serious consequences. We report 13 cases of feeding jejunostomy with balloon-inflated catheter's malfunction, some referred to our centre and others operated here over a period of 8 years. The most dramatic consequence of such improper use led to rupture of the small intestine due to inadvertent over-inflation (over 100 ml) of the balloon of the catheter during a contrast study. The patient required a laparotomy with resection and anastomosis of the bowel. Three other patients had similar over-inflation of the balloon leading to severe pain and discomfort. In all three patients, timely deflation of the balloon was sufficient to relieve the symptoms. One patient had intussusception with the inflated balloon acting as a lead point. The patient underwent resection of the small bowel with end jejunostomy and distal mucous fistula. All other patients presented with abdominal pain and distension and intestinal obstruction and were managed non-operatively with deflation of balloon either by aspiration, cutting the balloon port or ultrasound-guided puncture of balloon. Healthcare personnel dealing with patients with indwelling catheters must be educated to suspect, detect and manage such problems. The best measure for such unusual complications of otherwise safe devices would be prevention by training and generation of awareness.

  9. A short history of the Foley catheter: from handmade instrument to infection-prevention device.

    PubMed

    Carr, H A

    2000-02-01

    Although it is one of the most frequently utilized devices in the hospitalized patient, the Foley catheter has often been taken for granted. This lack of attention is unfortunate, as the Foley catheter remains one of the primary sources of hospital-acquired infections, which increase morbidity, mortality, and the financial burden on the healthcare system. Although education on the appropriate techniques, proper use, and early removal of Foley catheters is important, such measures unfortunately result in transient benefits. Current technologic advancements have moved the coating technology to a state where bacterial adhesion and migration can be limited and the frequency of catheter-associated urinary tract infections can be reduced. Future technological advances in the Foley catheter will help provide better care and comfort for the catheterized patient.

  10. A randomized trial of Foley balloon induction of labor trial in nulliparas (FIAT-N).

    PubMed

    Connolly, Katherine A; Kohari, Katherine S; Rekawek, Patricia; Smilen, Brooke S; Miller, Meredith R; Moshier, Erin; Factor, Stephanie H; Stone, Joanne L; Bianco, Angela T

    2016-09-01

    With an increasing rate of induction of labor, it is important to choose induction methods that are safe and efficient in achieving a vaginal delivery. The optimal method for inducing nulliparous women with an unfavorable cervix is not known. We sought to determine if induction of labor with simultaneous use of oxytocin and Foley balloon vs sequential use of Foley balloon followed by oxytocin decreases the time to delivery in nulliparous women. We conducted a randomized controlled trial of nulliparous women presenting for induction at a single institution from December 2013 through March 2015. After decision for induction was made by their primary provider, women with gestational age ≥24 weeks with a nonanomalous, singleton fetus in vertex presentation with intact membranes were offered participation. Exclusion criteria included history of uterine surgery, unexplained vaginal bleeding, latex allergy, or contraindication to vaginal delivery. Participants were randomized to either simultaneous (oxytocin and Foley balloon) or sequential (oxytocin after expulsion of Foley balloon) induction group. The primary outcome was time from induction to delivery. Secondary outcomes included mode of delivery, estimated blood loss, postpartum hemorrhage, chorioamnionitis, and composite neonatal outcome. Maternal and neonatal outcomes were collected via chart review. Analyses were done on an intention-to-treat basis. A total of 166 patients were enrolled; 82 in the simultaneous and 84 in the sequential group. There were no differences in baseline characteristics in the 2 groups. Patients who received simultaneous oxytocin with insertion of a Foley balloon delivered significantly earlier (15.92 vs 18.87 hours, P = .004) than those in the sequential group. There was no difference in rate of cesarean delivery, estimated blood loss, postpartum hemorrhage, chorioamnionitis, or composite neonatal outcome. Simultaneous use of oxytocin and Foley balloon for induction of labor results

  11. Foley catheter guide use during midurethral slings: does it make a difference?

    PubMed

    Miranne, Jeannine Marie; Dominguez, Aurora; Sokol, Andrew Ian; Gutman, Robert Eric; Iglesia, Cheryl Bernadette

    2015-06-01

    Our objective was to evaluate whether foley catheter guide use decreased the risk of cystotomy and urethrotomy during retropubic midurethral sling placement. This retrospective cohort study included all women undergoing retropubic synthetic midurethral sling placement at a single academic institution between January 2011 and September 2012. Patients were divided into groups based on whether or not the foley catheter guide was used during surgery. The primary outcome was the incidence of cystotomy. A total of 310 patients underwent retropubic midurethral sling placement. The foley catheter guide was used in 76/310 cases (24.5%). The mean age was 57 ± 11 and mean body mass index was 28 ± 7. More patients in the no-guide group had preoperative urgency (70% versus 58%, p = 0.049), anterior prolapse (95% versus 78%, p < 0.0001), and concomitant prolapse surgery (65% versus 51%, p = 0.03). There was no difference in preoperative urgency urinary incontinence, medical comorbidities, previous surgical history, intraoperative time, blood loss, or postoperative voiding dysfunction rates between groups. Fourteen of the 310 patients (4.5%) had cystotomies: 1/76 (1.3%) in the foley catheter guide group and 13/234 (5.6%) in the no-guide group (p = 0.12). No patients had urethrotomies. On multiple logistic regression, there was no difference in the odds of cystotomy between groups after adjusting for previous prolapse and anti-incontinence surgery, concomitant prolapse repair, level of first assistant, and retropubic local anesthesia use (AOR = 0.2 [95% CI 0.02-1.7]). Foley catheter guide use did not decrease the risk of intraoperative lower urinary tract injury during retropubic midurethral sling placement. Larger prospective studies are needed to confirm this finding.

  12. Acute Urinary Obstruction in a Tetraplegic Patient from Misplacement of Catheter in Urethra.

    PubMed

    Vaidyanathan, Subramanian; Singh, Gurpreet; Hughes, Peter L; Soni, Bakul M

    2016-01-01

    A male tetraplegic patient attended accident and emergency with a blocked catheter; on removing the catheter, he passed bloody urine. After three unsuccessful attempts were made to insert a catheter by nursing staff, a junior doctor inserted a three-way Foley catheter with a 30-mL balloon but inflated the balloon with 10 mL of water to commence the bladder irrigation. The creatinine level was mostly 19 µmol/L (range: 0-135 µmol/L) but increased to 46 µmol/L on day 7. Computerized tomography urogram revealed that the bilateral hydronephrosis with hydroureter was extended down to urinary bladder, the bladder was distended, prostatic urethra was dilated and filled with urine, and although the balloon of Foley catheter was not seen in the bladder, the tip of the catheter was seen lying in the urethra. Following the re-catheterization, the creatinine level decreased to 21 µmol/L. A follow-up ultrasound scan revealed no evidence of hydronephrosis in both kidneys. Flexible cystoscopy revealed inflamed bladder mucosa, catheter reaction, and tiny stones. There was no bladder tumor. This case report concludes that the cause of bilateral hydronephrosis, hydroureter, and distended bladder was inadequate drainage of urinary bladder as the Foley balloon that was under-filled slipped into the urethra resulting in an obstruction to urine flow. Urethral catheterization in tetraplegic patients should be performed by senior, experienced staff in order to avoid trauma and incorrect positioning. Tetraplegic subjects with decreased muscle mass have low creatinine level. Increase in creatinine level (>1.5 times the basal level) indicates acute kidney injury, although peak creatinine level may still be within laboratory reference range. While scanning the urinary tract of spinal cord injury patients with indwelling urinary catheter, if Foley balloon is not seen within the bladder, urethra should be scanned to locate the Foley balloon.

  13. A Rare Cause of Death in a Woman: Iatrogenic Bladder Rupture in a Patient With an Indwelling Foley Catheter.

    PubMed

    Paul, Anthea B Mahesan; Simms, Lary; Paul, Abraham E; Mahesan, Andrew A; Ramzanali, Ammani

    2016-05-01

    The CDC estimates that 12-25% of all hospitalized patients receive a urinary catheter during their hospital stay. Foley catheter failure is uncommon and Foley catheter failure associated with iatrogenic urinary bladder rupture (IUBR) is extremely rare. Symptoms are often nonspecific and thus misdiagnosis and delayed treatment is common. In this case report, we present a case of IUBR in a woman from Foley catheter failure, which ultimately led to her demise. This case adds to the literature the importance of suspicion for IUBR in patients with indwelling Foley catheters presenting with lower abdominal pain, hematuria, and decreased urine output.

  14. A Rare Cause of Death in a Woman: Iatrogenic Bladder Rupture in a Patient With an Indwelling Foley Catheter

    PubMed Central

    Paul, Anthea B. Mahesan; Simms, Lary; Paul, Abraham E.; Mahesan, Andrew A.; Ramzanali, Ammani

    2016-01-01

    The CDC estimates that 12–25% of all hospitalized patients receive a urinary catheter during their hospital stay. Foley catheter failure is uncommon and Foley catheter failure associated with iatrogenic urinary bladder rupture (IUBR) is extremely rare. Symptoms are often nonspecific and thus misdiagnosis and delayed treatment is common. In this case report, we present a case of IUBR in a woman from Foley catheter failure, which ultimately led to her demise. This case adds to the literature the importance of suspicion for IUBR in patients with indwelling Foley catheters presenting with lower abdominal pain, hematuria, and decreased urine output. PMID:27175339

  15. S-Nitroso-N-acetylpenicillamine (SNAP) Impregnated Silicone Foley Catheters: A Potential Biomaterial/Device To Prevent Catheter-Associated Urinary Tract Infections

    PubMed Central

    2016-01-01

    Urinary Foley catheters are utilized for management of hospitalized patients and are associated with high rates of urinary tract infections (UTIs). Nitric oxide (NO) potently inhibits microbial biofilm formation, which is the primary cause of catheter associated UTIs (CAUTIs). Herein, commercial silicone Foley catheters are impregnated via a solvent swelling method with S-nitroso-N-acetyl-D-penicillamine (SNAP), a synthetic NO donor that exhibits long-term NO release and stability when incorporated into low water-uptake polymers. The proposed catheters generate NO surface-fluxes >0.7 × 10–10 mol min–1 cm–2 for over one month under physiological conditions, with minimal SNAP leaching. These biomedical devices are demonstrated to significantly decrease formation of biofilm on the surface of the catheter tubings over 3, 7, and 14 day periods by microbial species (Staphylococcus epidermidis and Proteus mirabilis) commonly causing CAUTIs. Toxicity assessment demonstrates that the SNAP-impregnated catheters are fully biocompatible, as extracts of the catheter tubings score 0 on a 3-point grading scale using an accepted mouse fibroblast cell-line toxicity model. Consequently, SNAP-impregnated silicone Foley catheters can likely provide an efficient strategy to greatly reduce the occurrence of nosocomial CAUTIs. PMID:26462294

  16. Intraperitoneal Urinary Bladder Perforation with Pneumoperitoneum in Association with Indwelling Foley Catheter Diagnosed in Emergency Department.

    PubMed

    Zhan, Chenyang; Maria, Pedro P; Dym, R Joshua

    2017-11-01

    Indwelling Foley catheter is a rare cause of urinary bladder perforation, a serious injury with high mortality that demands accurate and prompt diagnosis. While the gold standard for diagnosis of bladder injury is computed tomography (CT) cystography, few bladder ruptures associated with Foley catheter have been reported to be diagnosed in the emergency department (ED). An 83-year-old man with indwelling Foley catheter presented to the ED for hematuria and altered mental status. He was diagnosed to have intraperitoneal rupture of the urinary bladder in the ED using abdominal and pelvic CT without contrast, which demonstrated bladder wall discontinuity, intraperitoneal free fluid, and pneumoperitoneum. The patient was treated successfully with medical management and bladder drainage. WHY SHOULD AN EMERGENCY PHYSICIAN BE AWARE OF THIS?: To our knowledge, this is the first report of intraperitoneal urinary bladder perforation associated with Foley catheter diagnosed in the ED by CT without contrast. Pneumoperitoneum found in this case was a clue to the diagnosis and is a benign finding that does not necessitate urgent surgical intervention. The early and accurate diagnosis in this case allowed for effective management with good clinical outcome. The use of indwelling Foley catheter has a high prevalence, especially in long-term care facility residents, who are frequent visitors in the ED. Therefore, emergency physicians and radiologists should be familiar with the presentation and imaging findings of this potential injury associated with Foley catheters. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. Using optical coherence tomography to detect bacterial biofilms on foley catheters (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Heidari, Andrew E.; Oh, Kyungjin; Chen, Zhongping

    2017-02-01

    Urinary tract infections(UTI) pose a serious problem for hospital patients accounting for 33% of all hospital acquired(nosocomial) infections with indwelling foley catheters. The presence of an indwelling foley catheter provides a scaffolding for circulating planktonic bacteria to adhere to and to form microbial biofilm communities that would typically be hindered by the body's innate immune system response. It is these biofilm communities that form on the inner lumen of foley catheters that provide a reservoir of pathogenic bacteria that could dislodge or disperse from the biofilm and infect urethra or bladder mucosal tissue in the urinary tract. Current diagnostic techniques of urine microbiological cultures are lacking in differentiating asymptomatic bacteriuria and symptomatic catheter-associated urinary tract infection(CAUTI) since almost all patients with chronic indwelling catheters are almost universally bacteriuruic. There is an unmet need of a diagnostic tool to assess the difference between the pathogenesis of asymptomatic bacteriuria and CAUTI, specifically at the site of the native biofilm formation. Optical Coherence Tomography(OCT) is an emerging high resolution, minimally invasive tomographic imaging technique that has shown promise in imaging biofilm structures previously in an endoscopic setting of the airway in-vivo and in microfluidic chambers. OCT can be adapted to image various sized biological surfaces and orifices such as airway branches and blood vessels by using a variety of minature endoscopic probes. In this work OCT will be used to image biofilm structure in-vitro on the inner lumen of extravasated critical care patient's foley catheters. Scanning electron microscopy will be conducted post OCT to confirm the presence of bacterial biofilm in OCT images.

  18. Determination of Isthmocele Using a Foley Catheter During Laparoscopic Repair of Cesarean Scar Defect.

    PubMed

    Akdemir, Ali; Sahin, Cagdas; Ari, Sabahattin Anil; Ergenoglu, Mete; Ulukus, Murat; Karadadas, Nedim

    2018-01-01

    To demonstrate a new technique of isthmocele repair via laparoscopic surgery. Case report (Canadian Task Force classification III). The local Ethics Committee waived the requirement for approval. Isthmocele localized at a low uterine segment is a defect of a previous caesarean scar due to poor myometrial healing after surgery [1]. This pouch accumulates menstrual bleeding, which can cause various disturbances and irregularities, including abnormal uterine bleeding, infertility, pelvic pain, and scar pregnancy [2-6]. Given the absence of a clearly defined surgical method in the literature, choosing the proper approach to treating isthmocele can be arduous. Laparoscopy provides a minimally invasive procedure in women with previous caesarean scar defects. A 28-year-old woman, gravida 2 para 2, presented with a complaint of prolonged postmenstrual bleeding for 5 years. She had undergone 2 cesarean deliveries. Transvaginal ultrasonography revealed a hypoechogenic area with menstrual blood in the anterior lower uterine segment. Magnetic resonance imaging showed an isthmocele localized at the anterior left lateral side of the uterus, with an estimated volume of approximately 12 cm 3 . After patient preparation, laparoscopy was performed. To repair the defect, the uterovesical peritoneal fold was incised and the bladder was mobilized from the lower uterine segment. During this surgery, differentiating the isthmocele from the abdomen can be challenging. Here we used a Foley catheter to identify the isthmocele. To do this, after mobilizing the bladder from the lower uterine segment, we inserted a Foley catheter into the uterine cavity through the cervical canal. We then filled the balloon of the catheter at the lower uterine segment under laparoscopic view, which allowed clear identification of the isthmocele pouch. The uterine defect was then incised. The isthmocele cavity was accessed, the margins of the pouch were debrided, and the edges were surgically reapproximated

  19. Usefulness of elastography in predicting the outcome of Foley catheter labour induction.

    PubMed

    Wozniak, Slawomir; Czuczwar, Piotr; Szkodziak, Piotr; Paszkowski, Tomasz

    2015-06-01

    Incorrect selection of women for labour induction may increase the risk of caesarean section and other postpartum and neonatal complications. It has been recently shown that elastography of the uterine cervix holds the potential to predict the outcome of pharmacological labour induction. There are no data on the usefulness of elastography in predicting the outcome of mechanical induction of labour. To assess the usefulness of elastographic cervical assessment in predicting the success of Foley catheter labour induction. This prospective observational study included 39 pregnant women at term with an unfavourable cervix (Bishop score ≤ 6) suitable for Foley catheter labour induction. Before labour induction the following data were recorded: Bishop score, cervical length (measured by ultrasound) and the stiffness of cervical internal os, canal and external os assessed by elastography (elastography index - EI). Statistical relationships between pre-interventional assessment of the cervix and outcome of Foley catheter labour induction (successful induction, time to delivery and route of delivery) were analysed. EI's of internal cervical os and cervical canal were significantly lower (softer) in women with successful labour induction and vaginal delivery, while EI's of the external cervical os, Bishop score and cervix length were not significantly different. Time to vaginal delivery was significantly correlated with the EI's of internal cervical os, cervical canal and Bishop score, but not with EI's of the external cervical os and cervix length. Elastography has the potential to predict the outcome of Foley catheter labour induction. © 2015 The Royal Australian and New Zealand College of Obstetricians and Gynaecologists.

  20. Women's Experiences with and Preference for Induction of Labor with Oral Misoprostol or Foley Catheter at Term.

    PubMed

    Ten Eikelder, Mieke L G; van de Meent, Marieke M; Mast, Kelly; Rengerink, Katrien Oude; Jozwiak, Marta; de Graaf, Irene M; Scholtenhuis, Marloes A G Holswilder-Olde; Roumen, Frans J M E; Porath, Martina M; van Loon, Aren J; van den Akker, Eline S; Rijnders, Robbert J P; Feitsma, A Hanneke; Adriaanse, Albert H; Muller, Moira A; de Leeuw, Jan W; Visser, Harry; Woiski, Mallory D; Weerd, Sabina Rombout-de; van Unnik, Gijs A; Pernet, Paula J M; Versendaal, Hans; Mol, Ben W; Bloemenkamp, Kitty W M

    2017-01-01

    Objective  We assessed experience and preferences among term women undergoing induction of labor with oral misoprostol or Foley catheter. Study Design  In 18 of the 29 participating hospitals in the PROBAAT-II trial, women were asked to complete a questionnaire within 24 hours after delivery. We adapted a validated questionnaire about expectancy and experience of labor and asked women whether they would prefer the same method again in a future pregnancy. Results  The questionnaire was completed by 502 (72%) of 695 eligible women; 273 (54%) had been randomly allocated to oral misoprostol and 229 (46%) to Foley catheter. Experience of the duration of labor, pain during labor, general satisfaction with labor, and feelings of control and fear related to their expectation were comparable between both the groups. In the oral misoprostol group, 6% of the women would prefer the other method if induction is necessary in future pregnancy, versus 12% in the Foley catheter group (risk ratio: 0.70; 95% confidence interval: 0.55-0.90; p =  0.02). Conclusion  Women's experiences of labor after induction with oral misoprostol or Foley catheter are comparable. However, women in the Foley catheter group prefer more often to choose a different method for future inductions. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  1. [Evaluation of the efficacy and safety of Foley catheter pre-induction of labor].

    PubMed

    Jagielska, Iwona; Kazdepka-Ziemińska, Anita; Janicki, Radosław; Fórmaniak, Jacek; Walentowicz-Sadłecka, Małgorzata; Grabiec, Marek

    2013-03-01

    Labor induction is being increasingly used (15-30% of pregnancies). The most common indications include late pregnancy preeclampsia, intrauterine fetal growth retardation (IUGR), hypertension. Preinduction by speeding up the ripening of the cervix increases the chances of successful induction. There are mechanical and pharmacological methods of pre-induction: the Foley catheter hygroscopic dilators, prostaglandin gel, misoprostol. There are various schemes of labor pre-induction and the differences relate primarily to duration of catheter time, amniotomy or the start of the oxytocin. Numerous studies on pre-induction and induction of labor aimed to compare the efficacy of these different methods. The effectiveness of the Foley catheter is usually assessed by comparing cervical maturity (Bishop score) and ripening of the cervix, evaluated in centimeters, before and after removing the cathetec time to labor since pre-induction and the number of births. In order to select the appropriate method, its safety for the mother and the fetus/newborn needs to be assessed. According to most authors, the use of a Foley catheter does not cause over-stimulation of the uterus, does not increase the risk of rupture or intrauterine infection, and does not adversely affect the fetus and newborn. To assess the efficacy and safety of labor pre-induction using a Foley catheter The study included 109 women hospitalized between 03.01.2011 and 11.30.2011, who underwent labor pre-induction with a Foley catheter The inclusion criteria were: one fetal pregnancy longitudinal cephalic fetal position, completed 36 weeks of pregnancy fetal bladder preserved, Bishop score < 5 points. The exclusion criteria were: placenta previa, uterine infection, unexplained bleeding, abnormal fetal heart rate, and other reasons preventing vaginal delivery such as fetal weight above 4500 g. Vaginal swabs for the presence of Streptococcus agalactiae (GBS) were obtained from each patient. In case of a positive

  2. 21 CFR 870.1350 - Catheter balloon repair kit.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Catheter balloon repair kit. 870.1350 Section 870... repair kit. (a) Identification. A catheter balloon repair kit is a device used to repair or replace the balloon of a balloon catheter. The kit contains the materials, such as glue and balloons, necessary to...

  3. 21 CFR 870.1350 - Catheter balloon repair kit.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Catheter balloon repair kit. 870.1350 Section 870... repair kit. (a) Identification. A catheter balloon repair kit is a device used to repair or replace the balloon of a balloon catheter. The kit contains the materials, such as glue and balloons, necessary to...

  4. 21 CFR 870.1350 - Catheter balloon repair kit.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Catheter balloon repair kit. 870.1350 Section 870... repair kit. (a) Identification. A catheter balloon repair kit is a device used to repair or replace the balloon of a balloon catheter. The kit contains the materials, such as glue and balloons, necessary to...

  5. Management of obstructed balloon catheters.

    PubMed Central

    Browning, G G; Barr, L; Horsburgh, A G

    1984-01-01

    Failure of a balloon catheter to deflate is not uncommon and prevents its removal. Methods of overcoming the problem include traction, bursting the balloon by overinflation, dissolving it with solvents, puncturing it percutaneously with a needle, or puncturing it with a wire stylet passed through the catheter. All except the last technique have major disadvantages and are of questionable safety. Transcatheter puncture of the balloon was used in 16 patients to remove obstructed balloon catheters without any technical difficulty, distress to the patient, or complication. The procedure is safe, simple, and does not require an anaesthetic. If necessary it could be performed safely by nursing or paramedical staff without the patient having to be admitted to hospital. It is the method of choice for the management of this problem. Images FIG 1 FIG 2 FIG 3 FIG 4 PMID:6428691

  6. Foley catheter placement for induction of labor with or without stylette: a randomized clinical trial.

    PubMed

    Forgie, Marie M; Greer, Danielle M; Kram, Jessica J F; Vander Wyst, Kiley B; Salvo, Nicole P; Siddiqui, Danish S

    2016-03-01

    Foley catheters are used for cervical ripening during induction of labor. Previous studies suggest that use of a stylette (a thin, rigid wire) to guide catheter insertion decreases insertion failure. However, stylette effects on insertion outcomes have been sparsely studied. The purpose of this study was to compare catheter insertion times, patient-assessed pain levels, and insertion failure rates between women who received a digitally placed Foley catheter for cervical ripening with the aid of a stylette and women who received the catheter without a stylette. We conducted a randomized clinical trial of women aged ≥ 18 years who presented for induction of labor. Inclusion criteria were singletons with intact membranes and cephalic presentation. Women received a computer-generated random assignment of a Foley catheter insertion with a stylette (treatment group, n = 62) or without a stylette (control group, n = 61). For all women, a standard insertion technique protocol was used. Three primary outcomes were of interest, including the following: (1) insertion time (total minutes to successful catheter placement), (2) patient-assessed pain level (0-10), and (3) failure rate of the randomly assigned insertion method. Treatment control differences were first examined using the Pearson's test of independence and the Student t test. Per outcome, we also constructed 4 regression models, each including the random effect of physician and fixed effects of stylette use with patient nulliparity, a history of vaginal delivery, cervical dilation at presentation, or postgraduate year of the performing resident physician. Women who received the Foley catheter with the stylette vs without the stylette did not differ by age, race/ethnicity, body mass index, or any of several other characteristics. Regression models revealed that insertion time, patient pain, and insertion failure were unrelated to stylette use, nulliparity, and history of vaginal delivery. However, overall insertion

  7. The effect of rectal Foley catheterization on rectal bleeding rates after transrectal ultrasound-guided prostate biopsy.

    PubMed

    Kilciler, Mete; Erdemir, Fikret; Demir, Erkan; Güven, Oğuz; Avci, Ali

    2008-09-01

    To assess whether Foley catheterization of the rectum after transrectal ultrasound (TRUS)-guided prostate biopsy decreases complication rates. Between June 2000 and September 2006, 275 consecutive patients were evaluated after undergoing TRUS-guided prostate biopsy. All procedures were performed on an outpatient basis. Patients were divided into two groups. In the first group (n = 134), a Foley catheter was inserted into the rectum and inflated to 50 cm(3) after TRUS-guided biopsy. In the second group (n = 141), catheterization was performed without balloon placement. Rectal bleeding, hematuria, hematospermia, infection, and acute urinary retention rates were compared between groups. The mean ages of the patients were 63.3 years +/- 5.6 and 62.1 years +/- 7.2 years in the Foley catheter group and control group, respectively (P = .112). Hematuria, hematospermia, infection, and rectal bleeding occurred in 31 (23.1%), 30 (22.4), nine (6.7%), and two patients (1.5%), respectively, in the Foley catheter group; and in 36 (25.5%), 36 (25.5%), 11 (7.8%), and 25 patients (17.7%), respectively, in the control group. The incidences of infection, hematuria, and hematospermia were not significantly different between groups (P > .05). In contrast, the rectal bleeding rate was significantly lower in the Foley catheter group (1.5%) than in the control group (17.7%; P = .001). Although it has no effect on other complications, TRUS-guided prostate biopsy with rectal Foley catheterization is a useful, practical method to decrease or prevent rectal bleeding.

  8. Retrieval of impacted broken balloon by balloon inflation in guiding catheter.

    PubMed

    Mehta, Vimal; Pandit, Bhagya Narayan; Yusuf, Jamal; Mukhopadhyay, Saibal; Trehan, Vijay; Tyagi, Sanjay

    2014-07-01

    Broken catheter fragment in a coronary artery during percutaneous coronary angioplasty is a rare complication. It can result in serious problems as a result of thrombus formation and embolization of broken fragment. We report an unusual complication of a broken balloon catheter during angioplasty, which was successfully retrieved by balloon inflation in guiding catheter technique.

  9. Use of monorail PTCA balloon catheter for local drug delivery.

    PubMed

    Trehan, Vijay; Nair, Girish M; Gupta, Mohit D

    2007-01-01

    We report the use of monorail coronary balloon as an infusion catheter to give bailout abciximab selectively into the site of stent thrombosis as an adjunct to plain old balloon angioplasty (POBA) in a patient of subacute stent thrombosis of the left anterior descending coronary artery. The balloon component (polyamide material) of the monorail balloon catheter was shaved off the catheter so that abciximab injected through the balloon port of the catheter exited out the shaft of the balloon catheter at the site from where the balloon material was shaved off. We believe that selective infusion with abciximab along with POBA established antegrade flow and relieved the patient's ischemia. In the absence of essential hardware to give intracoronary drugs in an emergency situation, one may employ our technique of infusion through a monorail balloon catheter after shaving the balloon component from the catheter.

  10. [The use of Foley catheter in reconstructive procedures involving the middle third of the facial skeleton].

    PubMed

    Medvedev, Yu A; Petruk, P S; Shamanaeva, L S; Volkova, V A; Davidov, A R

    2016-01-01

    The aim of this study was to improve the efficiency of surgical treatment of patients with fractures involving zygomatico-orbital complex and maxillary sinus through the use of Foley catheter. 352 patients with fractures of the middle third of the facial skeleton were treated at the Departments of Oral & Maxillofacial Surgery in Novokuznetsk Institute and I.M. Sechenov First MSMU. All patients underwent open reduction and osteosynthesis using extramedullary titanium mini-plates and NiTi mini-clamps. In the cases with large bone defects additional reconstructive techniques were used such as replantation of bone fragments and endoprosthesis with NiTi implants. For the purpose of drainage and retention Foley catheter was placed in the cavity of the maxillary sinus after the surgical procedure. We obtained good and satisfactory results in the majority of clinical cases. The use of Foley catheter was found to be very effective for the post-operative drainage and hemostasis of the maxillary sinus and in cases involving the use of fixation implant in the reconstructive surgeries in the middle third of the face.

  11. Cryo-balloon catheter localization in fluoroscopic images

    NASA Astrophysics Data System (ADS)

    Kurzendorfer, Tanja; Brost, Alexander; Jakob, Carolin; Mewes, Philip W.; Bourier, Felix; Koch, Martin; Kurzidim, Klaus; Hornegger, Joachim; Strobel, Norbert

    2013-03-01

    Minimally invasive catheter ablation has become the preferred treatment option for atrial fibrillation. Although the standard ablation procedure involves ablation points set by radio-frequency catheters, cryo-balloon catheters have even been reported to be more advantageous in certain cases. As electro-anatomical mapping systems do not support cryo-balloon ablation procedures, X-ray guidance is needed. However, current methods to provide support for cryo-balloon catheters in fluoroscopically guided ablation procedures rely heavily on manual user interaction. To improve this, we propose a first method for automatic cryo-balloon catheter localization in fluoroscopic images based on a blob detection algorithm. Our method is evaluated on 24 clinical images from 17 patients. The method successfully detected the cryoballoon in 22 out of 24 images, yielding a success rate of 91.6 %. The successful localization achieved an accuracy of 1.00 mm +/- 0.44 mm. Even though our methods currently fails in 8.4 % of the images available, it still offers a significant improvement over manual methods. Furthermore, detecting a landmark point along the cryo-balloon catheter can be a very important step for additional post-processing operations.

  12. The missing foley catheter: an unusual finding in vesicouterine fistula

    PubMed Central

    Shephard, Steven N.; Lengmang, Sunday J.

    2013-01-01

    A 28-year-old G1P1 presented complaining of urine leakage per vaginum following caesarean delivery, accompanied by amenorrhoea, cyclic haematuria and cyclic pelvic pain. Examination findings were suggestive of vesicouterine fistula and the patient was taken for exploratory laparotomy, during which the foley catheter could not be identified within the bladder. During separation of the bladder from the uterus, the catheter was found to be traversing the fistulous tract into the uterine cavity. Vesicouterine fistula is a fairly uncommon type of urogenital fistula that is frequently associated with caesarean section. Surgical treatment remains the mainstay and successfully cured this patient. PMID:24968444

  13. The missing foley catheter: an unusual finding in vesicouterine fistula.

    PubMed

    Shephard, Steven N; Lengmang, Sunday J

    2013-12-18

    A 28-year-old G1P1 presented complaining of urine leakage per vaginum following caesarean delivery, accompanied by amenorrhoea, cyclic haematuria and cyclic pelvic pain. Examination findings were suggestive of vesicouterine fistula and the patient was taken for exploratory laparotomy, during which the foley catheter could not be identified within the bladder. During separation of the bladder from the uterus, the catheter was found to be traversing the fistulous tract into the uterine cavity. Vesicouterine fistula is a fairly uncommon type of urogenital fistula that is frequently associated with caesarean section. Surgical treatment remains the mainstay and successfully cured this patient. Published by Oxford University Press and JSCR Publishing Ltd. All rights reserved. © The Author 2013.

  14. Labour induction at term--a randomised trial comparing Foley catheter plus titrated oral misoprostol solution, titrated oral misoprostol solution alone, and dinoprostone.

    PubMed

    Matonhodze, Baron B; Hofmeyr, G Justus; Levin, Jonathan

    2003-05-01

    To compare three methods of labour induction. Randomised controlled trial. Academic hospitals in Johannesburg, South Africa. Women with intact membranes due for induction of labour. Randomised, sealed opaque envelopes were used to allocate women to labour induction with extra-amniotic Foley catheter/titrated oral misoprostol solution (N = 174), titrated oral misoprostol solution alone (N = 176), or vaginal dinoprostone (N = 176). Misoprostol was dissolved in water and 20-40 g was given 2-hourly. These were failure to deliver vaginally within 24 hours, additional measures for induction or augmentation of labour, analgesia, and maternal and fetal complications. In the Foley catheter group, misoprostol was required in all but 1 case. Failure to deliver vaginally within 24 hours was similar for the three groups (79/174 v. 70/176 v. 70/176 respectively). Labour augmentation, caesarean section and instrumental delivery were used somewhat more frequently in the Foley/misoprostol group than in the misoprostol alone group, but these differences were not statistically significant. More analgesia was used in the Foley catheter/misoprostol group than in the misoprostol group (64/172 v. 46/175). Side-effects and neonatal complications were similar for the three groups. Use of extra-amniotic Foley catheter placement showed no measurable benefits over the use of oral misoprostol alone, or vaginal dinoprostone.

  15. Uterine packing versus Foley's catheter for the treatment of postpartum hemorrhage secondary to bleeding tendency in low-resource setting: A four-year observational study.

    PubMed

    Rezk, Mohamed; Saleh, Said; Shaheen, Abdelhamid; Fakhry, Tamer

    2017-11-01

    To assess the effectiveness and safety of uterine packing versus Foley's catheter tamponade for controlling postpartum hemorrhage (PPH) secondary to bleeding tendency after vaginal delivery. This was a prospective observational study conducted on 92 patients with primary PPH due to bleeding tendency following vaginal delivery who were unresponsive to uterotonics and bimanual compression of the uterus. Patients were divided into two groups, Uterine packing group (n = 45) and Foley catheter group (n = 47). The primary outcome was the success rate of the procedure. Secondary outcome addressed the maternal complications. The use of uterine packing resulted in stoppage of active bleeding in 93.3% of cases compared to only 68.1% in the Foley's catheter group (p < 0.05). Although the rate of minor complications namely fever, pain and urinary complaints were higher in the uterine packing group, it does not reach to a significant difference when compared to the Foley's catheter (p > 0.05). Six cases who failed to Foley catheter tamponade underwent emergency hysterectomy with no cases in the uterine packing group. The use of uterine packing to arrest PPH is simple, quick and safe procedure to avoid further surgical interventions and to preserve the fertility in low-resource setting.

  16. Under Pressure: Intraluminal Filling Pressures of Postpartum Hemorrhage Tamponade Balloons

    PubMed Central

    Antony, Kathleen M.; Racusin, Diana A.; Belfort, Michael A.; Dildy, Gary A.

    2017-01-01

    Objective Uterine tamponade by fluid-filled balloons is now an accepted method of controlling postpartum hemorrhage. Available tamponade balloons vary in design and material, which affects the filling attributes and volume at which they rupture. We aimed to characterize the filling capacity and pressure-volume relationship of various tamponade balloons. Study Design Balloons were filled with water ex vivo. Intraluminal pressure was measured incrementally (every 10 mL for the Foley balloons and every 50 mL for all other balloons). Balloons were filled until they ruptured or until 5,000 mL was reached. Results The Foley balloons had higher intraluminal pressures than the larger-volume balloons. The intraluminal pressure of the Sengstaken-Blakemore tube (gastric balloon) was initially high, but it decreased until shortly before rupture occurred. The Bakri intraluminal pressure steadily increased until rupture occurred at 2,850 mL. The condom catheter, BT-Cath, and ebb all had low intraluminal pressures. Both the BT-Cath and the ebb remained unruptured at 5,000 mL. Conclusion In the setting of acute hemorrhage, expeditious management is critical. Balloons that have a low intraluminal pressure-volume ratio may fill more rapidly, more easily, and to greater volumes. We found that the BT-Cath, the ebb, and the condom catheter all had low intraluminal pressures throughout filling. PMID:28497006

  17. Laser welding of balloon catheters

    NASA Astrophysics Data System (ADS)

    Flanagan, Aidan J.

    2003-03-01

    The balloon catheter is one of the principal instruments of non-invasive vascular surgery. It is used most commonly for angioplasty (and in recent years for delivering stents) at a multitude of different sites in the body from small arteries in the heart to the bilary duct. It is composed of a polymer balloon that is attached to a polymer shaft at two points called the distal and proximal bonds. The diverse utility of balloon catheters means a large range of component sizes and materials are used during production; this leads to a complexity of bonding methods and technology. The proximal and distal bonds have been conventionally made using cyanoacrylate or UV curing glue, however with performance requirements of bond strength, flexibility, profile, and manufacturing costs these bonds are increasingly being made by welding using laser, RF, and Hot Jaw methods. This paper describes laser welding of distal and proximal balloon bonds and details beam delivery, bonding mechanisms, bond shaping, laser types, and wavelength choice.

  18. Intraperitoneally placed Foley catheter via verumontanum initially presenting as a bladder rupture.

    PubMed

    Raheem, Omer A; Jeong, Young Beom

    2011-09-01

    Since urethral Foley catheterization is usually easy and safe, serious complications related to this procedure have been rarely reported. Herein, we describe a case of intraperitoneally placed urethral catheter via verumontanum presenting as intraperitoneal bladder perforation in a chronically debilitated elderly patient. A 82-yr-old male patient was admitted with symptoms of hematuria, lower abdominal pain after traumatic Foley catheterization. The retrograde cystography showed findings of intraperitoneal bladder perforation, but emergency laparotomy with intraoperative urethrocystoscopy revealed a tunnel-like false passage extending from the verumontanum into the rectovesical pouch between the posterior wall of the bladder and the anterior wall of the rectum with no bladder injury. The patient was treated with simple closure of the perforated rectovesical pouch and a placement of suprapubic cystostomy tube.

  19. 21 CFR 870.1350 - Catheter balloon repair kit.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Catheter balloon repair kit. 870.1350 Section 870.1350 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1350 Catheter balloon...

  20. 21 CFR 870.1350 - Catheter balloon repair kit.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Catheter balloon repair kit. 870.1350 Section 870.1350 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1350 Catheter balloon...

  1. Clinical experience with the Monorail balloon catheter for coronary angioplasty.

    PubMed

    Finci, L; Meier, B; Roy, P; Steffenino, G; Rutishauser, W

    1988-01-01

    The Monorail balloon catheter is distinctly different from other current balloon catheters: the guidewire passes through the balloon itself, exits the catheter proximal to the balloon, and runs alongside its small shaft (3 French) through the guiding catheter. Monorail coronary angioplasty was attempted in 61 patients on 73 lesions with balloons from 2.0 to 3.7 mm. Angiographic success was obtained in 66 lesions (90%). For 15 lesions, balloon exchanges were needed. In three lesions, the Monorail balloon failed to cross the lesion, while a standard balloon succeeded; two lesions could not be crossed with any balloon. Vessel occlusion occurred in four patients: two had emergency surgery without infarct (one died suddenly 4 days later and one had a stroke 1 day later), one was recanalized with a standard balloon, and one had a myocardial infarct. Continuous infusion of urokinase was used until patient 3 in whom problems with the delivery system led to cardiocerebral air embolization (with complete recovery). No thrombotic complications were observed in the subsequent 58 patients with only a bolus of 10,000 U of heparin. The Monorail balloon facilitates contrast injections and balloon exchanges but appears more difficult to pass through tight lesions. Omission of the previously recommended infusion with a thrombolytic agent proved safe.

  2. Inadvertent positioning of suprapubic catheter in urethra: a serious complication during change of suprapubic cystostomy in a spina bifida patient - a case report.

    PubMed

    Vaidyanathan, Subramanian; Hughes, Peter L; Soni, Bakul M; Oo, Tun; Singh, Gurpreet

    2009-12-22

    Spinal cord injury patients are at risk for developing unusual complications such as autonomic dysreflexia while changing suprapubic cystostomy. We report a male patient with spina bifida in whom the Foley catheter was placed in the urethra during change of suprapubic cystostomy with serious consequences. A male patient, born in 1972 with spina bifida and paraplaegia, underwent suprapubic cystostomy in 2003 because of increasing problems with urethral catheter. The patient would come to spinal unit for change of suprapubic catheter every four to six weeks. Two days after a routine catheter change in November 2009, this patient woke up in the morning and noticed that the suprapubic catheter had come out. He went straight to Accident and Emergency. The suprapubic catheter was changed by a health professional and this patient was sent home. But the suprapubic catheter did not drain urine. This patient developed increasing degree of pain and swelling in suprapubic region. He did not pass any urine per urethra. He felt sick and came to spinal unit five hours later. About twenty ml of contrast was injected through suprapubic catheter and X-rays were taken. The suprapubic catheter was patent; the catheter was not blocked. The Foley catheter could be seen going around in a circular manner through the urinary bladder into the urethra. The contrast did not opacify urinary bladder; but proximal urethra was seen. The tip of Foley catheter was lying in proximal urethra. The balloon of Foley catheter had been inflated in urethra. When the balloon of Foley catheter was deflated, this patient developed massive bleeding per urethra. A sterile 22 French Foley catheter was inserted through suprapubic track. The catheter drained bloody urine. He was admitted to spinal unit and received intravenous fluids and meropenem. Haematuria subsided after 48 hours. The patient was discharged home a week later in a stable condition. This case shows that serious complications can occur during

  3. Cryo-balloon catheter position planning using AFiT

    NASA Astrophysics Data System (ADS)

    Kleinoeder, Andreas; Brost, Alexander; Bourier, Felix; Koch, Martin; Kurzidim, Klaus; Hornegger, Joachim; Strobel, Norbert

    2012-02-01

    Atrial fibrillation (AFib) is the most common heart arrhythmia. In certain situations, it can result in life-threatening complications such as stroke and heart failure. For paroxsysmal AFib, pulmonary vein isolation (PVI) by catheter ablation is the recommended choice of treatment if drug therapy fails. During minimally invasive procedures, electrically active tissue around the pulmonary veins is destroyed by either applying heat or cryothermal energy to the tissue. The procedure is usually performed in electrophysiology labs under fluoroscopic guidance. Besides radio-frequency catheter ablation devices, so-called single-shot devices, e.g., the cryothermal balloon catheters, are receiving more and more interest in the electrophysiology (EP) community. Single-shot devices may be advantageous for certain cases, since they can simplify the creation of contiguous (gapless) lesion sets around the pulmonary vein which is needed to achieve PVI. In many cases, a 3-D (CT, MRI, or C-arm CT) image of a patient's left atrium is available. This data can then be used for planning purposes and for supporting catheter navigation during the procedure. Cryo-thermal balloon catheters are commercially available in two different sizes. We propose the Atrial Fibrillation Planning Tool (AFiT), which visualizes the segmented left atrium as well as multiple cryo-balloon catheters within a virtual reality, to find out how well cryo-balloons fit to the anatomy of a patient's left atrium. First evaluations have shown that AFiT helps physicians in two ways. First, they can better assess whether cryoballoon ablation or RF ablation is the treatment of choice at all. Second, they can select the proper-size cryo-balloon catheter with more confidence.

  4. Balloon catheter versus basket catheter for endoscopic bile duct stone extraction: a multicenter randomized trial.

    PubMed

    Ishiwatari, Hirotoshi; Kawakami, Hiroshi; Hisai, Hiroyuki; Yane, Kei; Onodera, Manabu; Eto, Kazunori; Haba, Shin; Okuda, Toshinori; Ihara, Hideyuki; Kukitsu, Takehiro; Matsumoto, Ryusuke; Kitaoka, Keisuke; Sonoda, Tomoko; Hayashi, Tsuyoshi

    2016-04-01

    Endoscopic bile duct stone (BDS) removal is a well-established treatment; however, the preference for basket or balloon catheters for extraction is operator-dependent. We therefore conducted a multicenter prospective randomized trial to compare catheter performance. We enrolled patients with a BDS diameter ≤ 10 mm and common bile duct diameter ≤ 15 mm. Participants were randomly assigned to groups that were treated with basket or balloon catheters between October 2013 and September 2014. The primary endpoint was the rate of complete clearance of the duct; the secondary endpoints were the rate and time to complete clearance in one endoscopic session. We initially enrolled 172 consecutive patients; 14 were excluded after randomization. The complete clearance rates were 92.3 % (72/78) in the balloon group and 80.0 % (64 /80) in the basket group. The difference in the rates between the two groups was 12.3 percentage points, indicating non-inferiority of the balloon method (non-inferiority limit -10 %; P < 0.001 for non-inferiority). Moreover, the balloon was superior to the basket (P = 0.037). The rate of complete clearance in one endoscopic session was 97.4 % using the balloon and 97.5 % using the basket (P = 1.00). The median times to complete clearance in one endoscopic session were 6.0 minutes (1 - 30) and 7.8 minutes (1 - 37) in the balloon and basket groups, respectively (P = 0.15). For extraction of BDSs ≤ 10 mm, complete endoscopic treatment with a single catheter is more likely when choosing a balloon catheter over a basket catheter.University Hospital Medical Information Network Trials Registry: UMIN000011887. © Georg Thieme Verlag KG Stuttgart · New York.

  5. Indwelling esophageal balloon catheter for benign esophageal stenosis in infants and children.

    PubMed

    van der Zee, David; Hulsker, Caroline

    2014-04-01

    Balloon dilatation of benign esophageal strictures is an established mode of therapy in adults and children. There remains a group of patients with refractory stenosis despite dilatation at regular intervals. An indwelling balloon catheter may offer an alternative. This is a retrospective study of 19 children who underwent esophagoscopy between 2004 and 2012 with placement of an indwelling balloon catheter for refractory esophageal stenosis. Total number of endoscopies, number of endoscopies with indwelling balloon catheter, as well as complications, reoperations, and mortality due to use of the balloon catheter were studied. Patient age ranged from 4 weeks to 15 years. The indwelling balloon catheter was used to treat refractory stenosis after corrective surgery of long gap esophageal atresia (n = 5), esophageal atresia with distal fistula (n = 2), refractory esophageal stenosis due to caustic esophageal burns (n = 7), reflux (n = 2), and stenosis of unknown cause (n = 3). With the indwelling balloon catheter in place, the mean number of endoscopies equalled four. Complications were restenosis after a symptom-free period for which a new indwelling balloon catheter was necessary (n = 3). Two others needed two to five additional dilations: balloon leakage requiring replacement (n = 7 in 5 patients), sputum retention (n = 1), and dislodgement (n = 5 in 4 patients). More importantly, there was no mortality or the need for any patient to undergo a surgical resection. The indwelling balloon catheter is safe to use and can be used by parents at home. More importantly it obviates the need for rethoracotomy/-scopy or esophageal replacement.

  6. False coronary dissection with the new Monorail angioplasty balloon catheter.

    PubMed

    Esplugas, E; Cequier, A R; Sabaté, X; Jara, F

    1990-01-01

    During percutaneous transluminal coronary angioplasty, the appearance of persistent staining in the vessel by contrast media suggests coronary dissection. We report seven patients in whom a false image of severe coronary dissection was observed during angioplasty performed with the new Monorail balloon catheter. This image emerges at the moment of balloon inflation, is distally located to the balloon, and disappears with balloon catheter deflation. No complications were associated with the appearance of this image.

  7. Inadvertent positioning of suprapubic catheter in urethra: a serious complication during change of suprapubic cystostomy in a spina bifida patient - a case report

    PubMed Central

    2009-01-01

    Introduction Spinal cord injury patients are at risk for developing unusual complications such as autonomic dysreflexia while changing suprapubic cystostomy. We report a male patient with spina bifida in whom the Foley catheter was placed in the urethra during change of suprapubic cystostomy with serious consequences. Case presentation A male patient, born in 1972 with spina bifida and paraplaegia, underwent suprapubic cystostomy in 2003 because of increasing problems with urethral catheter. The patient would come to spinal unit for change of suprapubic catheter every four to six weeks. Two days after a routine catheter change in November 2009, this patient woke up in the morning and noticed that the suprapubic catheter had come out. He went straight to Accident and Emergency. The suprapubic catheter was changed by a health professional and this patient was sent home. But the suprapubic catheter did not drain urine. This patient developed increasing degree of pain and swelling in suprapubic region. He did not pass any urine per urethra. He felt sick and came to spinal unit five hours later. About twenty ml of contrast was injected through suprapubic catheter and X-rays were taken. The suprapubic catheter was patent; the catheter was not blocked. The Foley catheter could be seen going around in a circular manner through the urinary bladder into the urethra. The contrast did not opacify urinary bladder; but proximal urethra was seen. The tip of Foley catheter was lying in proximal urethra. The balloon of Foley catheter had been inflated in urethra. When the balloon of Foley catheter was deflated, this patient developed massive bleeding per urethra. A sterile 22 French Foley catheter was inserted through suprapubic track. The catheter drained bloody urine. He was admitted to spinal unit and received intravenous fluids and meropenem. Haematuria subsided after 48 hours. The patient was discharged home a week later in a stable condition. Conclusion This case shows that

  8. Initial experience with the Europass: a new ultra-low profile monorail balloon catheter.

    PubMed

    Zimarino, M; Corcos, T; Favereau, X; Tamburino, C; Toussaint, M; Spaulding, C; Guérin, Y

    1994-09-01

    One of the causes for percutaneous transluminal coronary angioplasty (PTCA) failure is the inability to cross the lesion with the balloon catheter after guidewire positioning. The Europass coronary angioplasty catheter is a monorail Duralyn balloon catheter developed to enhance lesion crossability and to overcome this limitation. This system was evaluated in 50 patients in which target lesions were chronic total coronary occlusions (12 cases) or stenoses that could not be reached or crossed by other new monorail balloon catheters. Overall procedural success was obtained in 49/50 patients (98%), using a single Europass balloon catheter in 46/50 patients (92%), with no in-hospital complications. Its low profile, small distal shaft, and excellent trackability allowed successful angioplasty in cases where other catheters failed. This balloon catheter represents a significant advance in angioplasty technology and can be considered as a first-choice device for a safe and expeditious single-operator procedure.

  9. Onyx embolization using dual-lumen balloon catheter: initial experience and technical note.

    PubMed

    Paramasivam, Srinivasan; Niimi, Yasunari; Fifi, Johanna; Berenstein, Alejandro

    2013-10-01

    Onyx as an embolization agent for the management of vascular malformation is well established. We report our initial experience with dimethyl-sulphoxide (DMSO) compatible double lumen balloon catheters used for Onyx embolization. Between December 2011 and March 2013, we treated 22 patients aged between 1.5 to 70years with two types of DMSO compatible dual-lumen balloon catheters (Scepter C and Ascent) to treat dural arteriovenous fistulas, brain arteriovenous malformation (AVM) with dural feeders, mandibular, facial, lingual, vertebral and paravertebral AVMs. The catheter has good navigability, compliant balloon on inflation formed a "plug" that has more resistance than Onyx plug enhancing better penetration. During injection, the balloon remained stable without spontaneous deflation or rupture and withstood the pressure build-up well. The retrieval of the catheter in most cases took less than a minute (19/28) while in five, it was less than five minutes and in the remaining four, it was longer that includes a trapped catheter on prolonged attempted retrieval resulted in an epidural hematoma, requiring emergent surgical evacuation. The fluoroscopy time is reduced, as we do not form a proximal onyx plug, the injection time is shorter along with easy and instantaneous removal of the catheter after balloon deflation in most cases. Dual-lumen balloon catheter Onyx embolization is a safe and effective technique. Currently, an important tool to circumvent some of the shortcomings associated with Onyx embolization. The catheter has good navigability, the balloon has stability, tolerance, enhances penetrability. It is easy to retrieve the microcatheter. With the experience gained, and with more compliant balloon catheters available, this technique can be applied to cerebral vessels in near future. Copyright © 2013. Published by Elsevier Masson SAS.

  10. Hepatic venous outflow obstruction after living donor liver transplantation managed with ectopic placement of a foley catheter: A case report

    PubMed Central

    Wahab, Mohamed Abdel; Shehta, Ahmed; Hamed, Hosam; Elshobary, Mohamed; Salah, Tarek; Sultan, Ahmed Mohamed; Fathy, Omar; Elghawalby, Ahmed; Yassen, Amr; Shiha, Usama

    2015-01-01

    Introduction The early hepatic venous outflow obstruction (HVOO) is a rare but serious complication after liver transplantation, which may result in graft loss. We report a case of early HVOO after living donor liver transplantation, which was managed by ectopic placement of foley catheter. Presentation A 51 years old male patient with end stage liver disease received a right hemi-liver graft. On the first postoperative day the patient developed impairment of the liver functions. Doppler ultrasound (US) showed absence of blood flow in the right hepatic vein without thrombosis. The decision was to re-explore the patient, which showed torsion of the graft upward and to the right side causing HVOO. This was managed by ectopic placement of a foley catheter between the graft and the diaphragm and the chest wall. Gradual deflation of the catheter was gradually done guided by Doppler US and the patient was discharged without complications. Discussion Mechanical HVOO results from kinking or twisting of the venous anastomosis due to anatomical mismatch between the graft and the recipient abdomen. It should be managed surgically by repositioning of the graft or redo of venous anastomosis. Several ideas had been suggested for repositioning and fixation of the graft by the use of Sengstaken–Blakemore tubes, tissue expanders, and surgical glove expander. Conclusion We report the use of foley catheter to temporary fix the graft and correct the HVOO. It is a simple and safe way, and could be easily monitored and removed under Doppler US without any complications. PMID:25805611

  11. Onyx Embolization for Isolated Type Dural Arteriovenous Fistula Using a Dual-Lumen Balloon Catheter.

    PubMed

    Kim, Jin Woo; Kim, Byung Moon; Park, Keun Young; Kim, Dong Joon; Kim, Dong Ik

    2016-05-01

    Utilization of a dual-lumen balloon may improve Onyx penetration into isolated dural arteriovenous fistulas (i-DAVFs). To compare the results of Onyx embolization using a dual-lumen balloon with those using a non-balloon catheter for i-DAVFs. Twenty-nine patients underwent Onyx embolization for i-DAVFs using a non-balloon (n = 14) or a dual-lumen balloon catheter (n = 15). Since its introduction, a dual-lumen balloon catheter has been preferred. We compared the dual-lumen balloon group with the non-balloon catheter group regarding angiographic outcome, treatment-related complications, total procedural time, Onyx injection time, and the number of feeders requiring embolization. The dual-lumen balloon group showed complete occlusion of i-DAVFs in 13 and near-complete in 2 patients, while the non-balloon group showed complete occlusion in 5, near-complete in 5, and incomplete in 4 patients (P < .05). Treatment-related complications occurred in 2 patients: 1 in the non-balloon group and 1 in the dual-lumen balloon group. The mean total procedural time was 62 ± 32 minutes in the dual-lumen balloon and 171 ± 88 minutes in the non-balloon group (P < .05). The mean Onyx injection time was 10 ± 6 minutes in the dual-lumen balloon and 49 ± 32 minutes in the non-balloon group (P < .05). The median number of feeders requiring embolization was 1 (range, 1-3) in the dual-lumen balloon and 2 (range, 1-4) in the non-balloon group (P < .05). Utilization of a dual-lumen balloon catheter for Onyx embolization of i-DAVF seemed to significantly increase the immediate complete occlusion rate and decrease total procedural time, Onyx injection time, and number of feeders requiring embolization.

  12. Indwelling catheter care

    MedlinePlus

    ... it overnight. You will be shown how to disconnect the bags from the Foley catheter in order ... bags through a separate valve without needing to disconnect the bag from the Foley catheter. Making Sure ...

  13. Opportunistic use of a Foley catheter to provide a common electrocautery with a water-irrigating channel for hepatic parenchymal transection.

    PubMed

    Yamamoto, Yuzo; Yoshioka, Masato; Watanabe, Go; Uchinami, Hiroshi

    2015-11-01

    High-tech surgical energy devices that are used during a single surgery have increased in number and the expense for such disposable units is by no means negligible. We developed a handmade water-irrigating monopolar electrocautery using a Foley catheter to perform liver parenchymal transection. A commonly used 20-24 Fr Foley catheter was cut at a length of about 8 cm. The shaft of the 5 mm ball electrode measuring 13.5 cm in length was then inlaid into the urine drainage channel. The target tissues were cauterized without making an eschar, thereby preventing the adhesion of the electrode to the tissues. A ball electrode with our handmade water irrigation sheath can be made in only a few minutes at a very low cost, using common medical supplies and yielding satisfactory effects comparable to the use of specialized high-tech devices.

  14. Traditional Foley drainage systems--do they drain the bladder?

    PubMed

    Garcia, Maurice M; Gulati, Shelly; Liepmann, Dorian; Stackhouse, G Bennett; Greene, Kirsten; Stoller, Marshall L

    2007-01-01

    Foley catheters are assumed to drain the bladder to completion. Drainage characteristics of Foley catheter systems are poorly understood. To investigate unrecognized retained urine with Foley catheter drainage systems, bladder volumes of hospitalized patients were measured with bladder scan ultrasound volumetrics. Additionally, an in vitro bench top mock bladder and urinary catheter system was developed to understand the etiology of such residual volumes. A novel drainage tube design that optimizes indwelling catheter drainage was also designed. Bedside bladder ultrasound volumetric studies were performed on patients hospitalized in ward and intensive care unit. If residual urine was identified the drainage tubing was manipulated to facilitate drainage. An ex vivo bladder-urinary catheter model was designed to measure flow rates and pressures within the drainage tubing of a traditional and a novel drainage tube system. A total of 75 patients in the intensive care unit underwent bladder ultrasound volumetrics. Mean residual volume was 96 ml (range 4 to 290). In 75 patients on the hospital ward mean residual volume was 136 ml (range 22 to 647). In the experimental model we found that for every 1 cm in curl height, obstruction pressure increased by 1 cm H2O within the artificial bladder. In contrast, the novel spiral-shaped drainage tube demonstrated rapid (0.5 cc per second), continuous and complete (100%) reservoir drainage in all trials. Traditional Foley catheter drainage systems evacuate the bladder suboptimally. Outflow obstruction is caused by air-locks that develop within curled redundant drainage tubing segments. The novel drainage tubing design eliminates gravity dependent curls and associated air-locks, optimizes flow, and minimizes residual bladder urine.

  15. Snare-assisted anterograde balloon mitral and aortic valvotomy using Inoue balloon catheter.

    PubMed

    Krishnan, Mangalath N; Syamkumar, M D; Sajeev, C G; Venugopal, K; Johnson, Francis; Vinaykumar, D; Velayudhan, C C; Jayakumar, T G

    2007-01-02

    We performed concurrent antegrade mitral and aortic valvotomy using Inoue dilatation catheter in 3 cases of combined rheumatic mitral and aortic stenosis. Following mitral valvotomy by standard procedure, aortic valve was crossed with the help of a floatation catheter. Stiff long length guide wire was fixed in descending aorta using a snare. Inoue catheter was threaded over the wire across the aortic valve and aortic valvotomy completed. Mitral valve area increased from mean 1 cm2 to 2 cm2; aortic gradient dropped from mean of 97 mm to 36 mm. Concurrent anterograde balloon mitral and aortic valvotomy may be effective and safe.

  16. Innovations in Balloon Catheter Technology in Rhinology.

    PubMed

    D'Anza, Brian; Sindwani, Raj; Woodard, Troy D

    2017-06-01

    Since being introduced more than 10 years ago, balloon catheter technology (BCT) has undergone several generations of innovations. From construction to utilization, there has been a myriad of advancements in balloon technology. The ergonomics of the balloon dilation systems have improved with a focus on limiting the extra assembly. "Hybrid" BCT procedures have shown promise in mucosal preservation, including treating isolated complex frontal disease. Multiple randomized clinical trials report improved long-term outcomes in stand-alone BCT, including in-office use. The ever-expanding technological innovations ensure BCT will be a key component in the armamentarium of the modern sinus surgeon. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. Balloon augmented Onyx embolization utilizing a dual lumen balloon catheter: utility in the treatment of a variety of head and neck lesions.

    PubMed

    Spiotta, Alejandro M; Miranpuri, Amrendra S; Vargas, Jan; Magarick, Jordan; Turner, Raymond D; Turk, Aquilla S; Chaudry, M Imran

    2014-09-01

    Endovascular embolization for tumors and vascular malformations has emerged as an important preoperative adjunct prior to resection. We describe the advantages of utilizing a recently released dual lumen balloon catheter for ethylene vinyl alcohol copolymer, also known as Onyx (ev3, Irvine, California, USA), embolization for a variety of head and neck pathologies. A retrospective review of all cases utilizing the Scepter C balloon catheter (MicroVention Inc, Tustin, California, USA) for use in balloon augmented embolization was performed over a 4 month period from October 2012 to February 2013 at the Medical University of South Carolina, Charleston, South Carolina, USA. Charts and angiographic images were reviewed. Representative cases involving diverse pathologies are summarized and illustrate the observed advantages of balloon augmented Onyx embolization with a dual lumen balloon catheter. Balloon augmented Onyx embolization utilizing a novel dual lumen balloon catheter was employed to treat both ruptured and unruptured arteriovenous malformations, intracranial dural arteriovenous fistulae, intracranial neoplasms, carotid body tumors, a thyroid mass, and an extracranial arteriovenous fistula. The dual lumen balloon catheter has several advantages for use with Onyx embolization over older devices, including more efficient proximal plug formation and enhanced navigability for placement deep within the pedicles. The balloon augmented Onyx embolization technique represents a valuable tool to add to the armamentarium of the neurointerventionalist to address a variety of head and neck lesions. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  18. Application of new balloon catheters in the treatment of congenital heart defects

    PubMed Central

    Fiszer, Roland; Szkutnik, Małgorzata; Smerdziński, Sebastian; Chodór, Beata; Białkowski, Jacek

    2016-01-01

    Introduction Balloon angioplasty (BAP) and aortic or pulmonary balloon valvuloplasty (BAV, BPV) are well-established treatment options in congenital heart defects. Recently, significant technological progress has been made and new catheters have been implemented in clinical practice. Aim To analyze the results of BAP, BAV and BPV with the new balloon catheter Valver and its second generation Valver II, which the company Balton (Poland) launched and developed. These catheters have not been clinically evaluated yet. Material and methods We performed 64 interventions with Valver I and Valver II. With Valver I the following procedures were performed: 17 BPV (including 9 in tetralogy of Fallot – TOF), 10 BAV and 27 BAP in coarctations of the aorta (CoA) – including 9 native and 18 after surgery. With Valver II ten interventions were done – 3 BPV, 2 pulmonary supravalvular BAP (after switch operations), 2 BAP of recoarctations and 3 other BAP. Age of the patients ranged from a few days to 40 years. Results All procedures were completed successfully, without rupture of any balloon catheters. The pressure gradient drop was statistically significant in all groups: BPV in isolated pulmonary valvular stenosis 28.1 mm Hg (mean), BPV in TOF 18.7 mm Hg, BAV 32.8 mm Hg, BAP in native CoA 15.4 mm Hg and in recoarctations 18.6 mm Hg. In 3 cases during rapid deflation of Valver I, wrinkles of the balloons made it impossible to insert the whole balloon into the vascular sheath (all were removed surgically from the groin). No such complication occured with Valver II. Conclusions Valver balloon catheters are an effective treatment modality in different valvular and vascular stenoses. PMID:27625686

  19. Observations on the development of the crystalline bacterial biofilms that encrust and block Foley catheters.

    PubMed

    Stickler, D J; Morgan, S D

    2008-08-01

    The care of many patients undergoing long-term bladder catheterisation is complicated when the flow of urine through the catheter is blocked by encrustation. The problem results from infection by urease-producing bacteria, especially Proteus mirabilis, and the subsequent formation of crystalline biofilms on the catheter. The aim of this study was to discover how P. mirabilis initiates the development of these crystalline biofilms. The early stages in the formation of the biofilms were observed on a range of Foley catheters in a laboratory model of the catheterised bladder. Scanning electron micrographs revealed that when all-silicone, silicone-coated latex, hydrogel-coated latex, hydrogel/silver-coated latex and nitrofurazone silicone catheters were inserted into bladder models containing P. mirabilis and alkaline urine, their surfaces were rapidly coated with a microcrystalline foundation layer. X-ray microanalysis showed that this material was composed of calcium phosphate. Bacterial colonisation of the foundation layer followed and by 18h the catheters were encrusted by densely populated crystalline P. mirabilis biofilms. These observations have important implications for the development of encrustation-resistant catheters. In the case of silver catheters for example, bacterial cells can attach to the crystalline foundation layer and continue to grow, protected from contact with the underlying silver. If antimicrobials are to be incorporated into catheters to prevent encrustation, it is important that they diffuse into the urine and prevent the rise in pH that triggers crystal formation.

  20. Use of mechanical devices for distal hemoperfusion during balloon catheter coronary angioplasty.

    PubMed

    Heibig, J; Angelini, P; Leachman, D R; Beall, M M; Beall, A C

    1988-01-01

    Previous attempts to protect the dependent myocardium during balloon catheter coronary angioplasty in animals and humans have had generally unsatisfactory results. This paper summarizes the authors' experience in investigating commercially available mechanical pumps for distal coronary hemoperfusion during balloon angioplasty. Both roller and piston pumps can attain adequate distal perfusion without significant side effects in the majority of patients. Our goal was to suppress angina for at least 5 min to prolong balloon inflation in awake patients. Minor T-wave changes without concomitant angina pectoris can be expected when the distal coronary bed is perfused with hypothermic blood. Side branch occlusion by the inflated balloon prevents effective protection of the corresponding part of the dependent myocardium during distal hemoperfusion, which may result in persistent angina and ST-T changes uncorrected by increasing the hemoperfusion rate. Distal coronary diffuse spasm, rare and transient, was the only immediate complication of this procedure. It is suggested that intense local wall stimulation could occur with a higher flow rate (jet effect). Improved balloon catheter pressure/flow characteristics and on-line continuous mechanical pumps should soon make distal coronary hemoperfusion through balloon catheters an accepted clinical technique.

  1. Does water-perfused catheter overdiagnose anismus compared to balloon probe?

    PubMed

    Savoye, G; Leroi, A M; Bertot-Sassigneux, P; Touchais, J Y; Devroede, G; Denis, P

    2002-12-01

    The purpose of this study was to compare the manometric assessment of straining effort as if to defecate and rectoanal inhibitory reflex obtained with a rectosphincteric balloon probe and with a water-perfused catheter in the same subject. Twelve healthy volunteers underwent two manometric assessments of anal sphincter function and electromyographic (EMG) surface recordings. one with a rectosphincteric balloon and one with a water-perfused catheter, 7 days apart in random order. Increased EMG activity in the external anal sphincter in the midst of the rectoanal inhibitory reflex (P < 0.001) and during straining for defecation (P < 0.001) was more frequently observed with the perfused system than with the balloon probe. There was a discrepancy between the EMG activity of the external anal sphincter and the anal pressures during straining recorded with the perfused system. Duration of the reflex elicited by rectal distension with 10 and 20 ml of air was significantly greater with the rectosphincteric balloon than with the perfused catheter (P = 0.02 and P = 0.05, respectively). Water instilled in the anal canal by the perfused system induces artifacts in EMG recording and active anal contractions. These artifacts and induced contractions could lead to an erroneous diagnosis of anismus, particularly if pelvic floor EMG is only taken into account for the diagnosis of anismus.

  2. A comparison of the effect of early insertion of standard latex and silver-impregnated latex foley catheters on urinary tract infections in burn patients.

    PubMed

    Newton, Terry; Still, Joseph M; Law, Edward

    2002-04-01

    A retrospective study was designed to compare the incidence of urinary tract infections during two different time periods in burn patients treated with two different types of Foley catheters. In time period 1, latex catheters present on admission were not changed. In time period 2, catheters were replaced on admission with silver alloy-impregnated catheters. In time period 1, the rate of symptomatic urinary tract infections was 7.2 per 1,000 catheter-days. In time period 2, the rate was 4.4 per 1,000 catheter-days. Results, compared using Fisher's exact test, revealed a statistically significant P value of .029. The use of silver-impregnated catheters significantly lowered the rate of urinary tract infection at our burn center.

  3. [Combination of the ureteral dilation catheter and balloon catheter under the ureteroscope in the treatment of male urethral stricture].

    PubMed

    Zhou, Yi; Li, Gong-hui; Yan, Jia-jun; Shen, Cong; Tang, Gui-hang; Xu, Gang

    2016-01-01

    To investigate the clinical application of the ureteral dilation catheter combined with the balloon catheter under the ureteroscope in the treatment of urethral stricture in men. Under the ureteroscope, 45 male patients with urethral stricture received placement of a zebra guide wire through the strictured urethra into the bladder and then a ureteral dilation catheter along the guide wire, followed by dilation of the urethra from F8 initially to F14 and F16. Again, the ureteroscope was used to determine the length of the strictured urethra, its distance to the external urethral orifice, and whether it was normally located. An F24 balloon catheter and then a metal urethral calibrator was used for the dilation of the strictured urethra. After removal of the F18-F22 urethral catheter at 8 weeks, the urinary flow rate was measured immediately and again at 3 months. All the operations were successfully performed without serious complications. The maximum urinary flow rate was (13.3-29.9) ml/s (mean [17.7 ± 3.2] ml/s) at the removal of the catheter and (15.2-30.8) ml/s (mean [19.8 ± 3.9] ml/s) at 3 months after it. Smooth urination was found in all the patients during the 6-24 months follow-up. The application of the ureteral dilation catheter combined with, the balloon catheter under the ureteroscope is a good option for the treatment of male urethral stricture for its advantages of uncomplicatedness, safety, effectiveness, few complications, less pain, high success rate, and repeatable operation.

  4. [Valvuloplasty with balloon catheter in biologic prosthesis. Reality or illusion].

    PubMed

    Ledesma Velasco, M; Verdín Vázquez, R; Acosta Valdez, J L; Munayer Calderón, J; Salgado Escobar, J L; Arias Monroy, L; Flores Mendoza, J

    1989-01-01

    We performed catheter balloon valvuloplasty (CBV) on 8 stenotic operatively-excised bioprosthetic valves (2 Hancock and 6 Ionescu Shiley). Pathology of valves before CBV included degenerative changes: commissural fusion by mounds of calcific deposits (2 valves), fibrotic and focally calcified leaflets (7 valves) and stiff and thick valves (1 valve). Inflation of the balloon resulted in commissural splitting (2 valves), leaflet cracks and fractures (3 valves). Removal of the deflated balloon catheter was associated with debris dislodgement (3 valves). In one case the valve was unable to close with potential for acute regurgitation. Thus, CBV of bioprosthetic valves can split fused commissures by similar mechanisms as in native valves. CBV may fracture calcific deposits causing acute emboli. It can also disrupt the leaflets causing acute insufficiency. The findings suggest a limited role of CBV in the treatment of stenotic bioprosthetic valves in mitral and aortic position.

  5. [Pressure-volume recording of PTCA catheters with balloons of lower and higher compliance].

    PubMed

    Werner, C; Bloss, P; Kiessling, D; Patzschke, H; Unverdorben, M; Vallbracht, C

    1999-11-01

    In this report, the results of complementary studies of pressure-volume (p-V) measurements on balloon catheters with balloons of low (LC) and high compliance (HC) used for percutaneous transluminal coronary angioplasty are discussed. The measurements were performed with balloons unconfined in air (free dilatation) and also confined in different shells. In the case of rigid shells, a surprisingly high self-expansion of the catheters was found. Although this self-expansion does not contribute to the radial dilatation, it cannot be neglected, but must be taken into account when the success of balloon dilatation is determined on the basis of measured p-V curves. The investigations performed using wrapped shells clearly show the different dilatation properties of LC and HC balloons. The results provide important information on the feasibility of controlled balloon dilatation on the basis of p-V measurements performed on-line during PTCA.

  6. REcanalisation and Balloon-Oriented Puncture for Re-Insertion of Dialysis Catheter in Nonpatent Central Veins (REBORN)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Too, Chow Wei, E-mail: toochowwei@gmail.com; Sayani, Raza; Lim, Elvin Yuan Ting

    PurposeTo describe a technique involving REcanalisation and Balloon-Oriented puncture for Re-insertion of dialysis catheter in Nonpatent central veins (REBORN) and to report long-term results.Materials and MethodsThis is a retrospective study of ten subjects in whom dialysis catheters were inserted using the REBORN technique from March 2012 to October 2014 and followed up till April 2016. Data on the duration of catheter usage, complications and reasons for removal were obtained. Seven patients had partially occluded lower internal jugular veins (IJV) recanalised in an antegrade fashion via a more cranial puncture. The balloon was then inflated at usual puncture site with anmore » 18G needle. The collapsed balloon was cannulated with a guide wire, and both balloon and guide wire were advanced together into the superior vena cava. This was followed by tunnelled catheter placement using standard techniques. Two patients had catheters placed in the subclavian vein using a similar antegrade technique, and one patient had catheter placed via the left IJV following retrograde recanalisation from a right femoral puncture.ResultsMean duration of catheter use was 278 days (range 32–503). Three catheters were removed due to matured arteriovenous accesses. Four patients had successful catheter change over the same subcutaneous track due to catheter malfunction. One catheter was removed after 7 months because of sepsis. No complications were reported.ConclusionThe REBORN technique allows for the preservation of central veins for future haemodialysis access, which can be challenging in patients requiring long-term dialysis.« less

  7. Endoscopic endonasal control of the paraclival internal carotid artery by Fogarty balloon catheter inflation: an anatomical study.

    PubMed

    Ruggeri, Andrea; Enseñat, Joaquim; Prats-Galino, Alberto; Lopez-Rueda, Antonio; Berenguer, Joan; Cappelletti, Martina; De Notaris, Matteo; d'Avella, Elena

    2017-03-01

    OBJECTIVE Neurosurgical management of many vascular and neoplastic lesions necessitates control of the internal carotid artery (ICA). The aim of this study was to investigate the feasibility of achieving control of the ICA through the endoscopic endonasal approach by temporary occlusion with a Fogarty balloon catheter. METHODS Ten endoscopic endonasal paraseptal approaches were performed on cadaveric specimens. A Fogarty balloon catheter was inserted through a sellar bony opening and pushed laterally and posteriorly extraarterially along the paraclival carotid artery. The balloon was then inflated, thus achieving temporary occlusion of the vessel. The position of the catheter was confirmed with CT scans, and occlusion of the ICA was demonstrated with angiography. The technique was performed in 2 surgical cases of pituitary macroadenoma with cavernous sinus invasion. RESULTS Positioning the Fogarty balloon catheter at the level of the paraclival ICA was achieved in all cadaveric dissections and surgical cases through a minimally invasive, quick, and safe approach. Inflation of the Fogarty balloon caused interruption of blood flow in 100% of cases. CONCLUSIONS Temporary occlusion of the paraclival ICA performed through the endoscopic endonasal route with the aid of a Fogarty balloon catheter may be another maneuver for dealing with intraoperative ICA control. Further clinical studies are required to prove the efficacy of this method.

  8. Balloon catheter dilation and nasolacrimal duct intubation for treatment of nasolacrimal duct obstruction after failed probing.

    PubMed

    Repka, Michael X; Chandler, Danielle L; Holmes, Jonathan M; Hoover, Darren L; Morse, Christine L; Schloff, Susan; Silbert, David I; Tien, D Robbins

    2009-05-01

    To compare the outcomes of balloon catheter dilation and nasolacrimal intubation as treatment for congenital nasolacrimal duct obstruction after failed probing in children younger than 4 years. We conducted a prospective, nonrandomized, multicenter study that enrolled 159 children aged 6 months to younger than 48 months who had a history of a single failed nasolacrimal duct probing and at least 1 of the following clinical signs of nasolacrimal duct obstruction: epiphora, mucous discharge, or increased tear lake. One hundred ninety-nine eyes underwent either balloon catheter nasolacrimal duct dilation or nasolacrimal duct intubation. Treatment success was defined as absence of epiphora, mucous discharge, or increased tear lake at the outcome visit 6 months after surgery. Treatment success was reported in 65 of 84 eyes (77%; 95% confidence interval, 65%-85%) in the balloon catheter dilation group compared with 72 of 88 eyes (84% after adjustment for intereye correlation; 74%-91%) in the nasolacrimal intubation group (risk ratio for success for intubation vs balloon dilation, 1.08; 0.95-1.22). Both balloon catheter dilation and nasolacrimal duct intubation alleviate the clinical signs of persistent nasolacrimal duct obstruction in a similar percentage of patients.

  9. Evaluation of a New Balloon Catheter for Difficult Calcified Lesions in Infrainguinal Arterial Disease: Outcome of a Multicenter Registry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Spaargaren, G. J.; Lee, M. J.; Reekers, J. A.

    2009-01-15

    The purpose of this study was to assess the technical performance and immediate procedure outcome of a new balloon catheter in the treatment of calcified lesions in infrainguinal arterial disease. Seventy-five patients with infrainguinal arterial disease were prospectively entered into the registry. The catheter (ReeKross Clearstream, Ireland) is a 5- to 6-Fr balloon catheter with a rigid shaft intended for enhanced pushability. Only technical procedural outcome was recorded. Treated calcified lesions (range: 5-30 cm), assessed angiographically, were located in the superficial femoral, popliteal, and crural arteries. In 67 patients the lesion was an occlusion. Guidewire passage occurred subintimally in 68more » patients. In 24 patients a standard balloon catheter was chosen as first treatment catheter: 5 failed to cross the lesion, 8 balloons ruptured, and in 11 patients there was an inadequate dilatation result. In only one of the five patients did subsequent use of the ReeKross catheter also fail in lesion crossing. The ReeKross was successful as secondary catheter in the other 23 cases. In 50 patients the ReeKross was used as primary catheter. In total the ReeKross crossed the lesions in 74 patients. After passage and dilatation with this catheter in 73 patients (1 failed true-lumen reentry), 19 had >30% residual lesions, of which 11 were not treated and 8 were successfully stented. No ReeKross balloons ruptured. We conclude that in the treatment of difficult calcified lesions in arterial stenotic or occlusive disease, the choice of a high-pushability angioplasty catheter, with more calcification-resistant balloon characteristics, like the ReeKross, warrants consideration.« less

  10. [Testing methods for the characterization of catheter balloons and lumina].

    PubMed

    Werner, C; Rössler, K; Deckert, F

    1995-10-01

    The present paper reports on the characterization of catheter balloons and lumina on the basis of such known parameters as residual volume, compliance, burst pressure and flow rate, with the aim of developing standards, test methods and testing equipment as well as standards. These are becoming ever more important with the coming into force of the EC directive on medical products [7] and the law governing medical products in Germany [13], which requires manufacturers to specify the properties of their products. Our testing concept is based on a commercially available machine that subjects materials to alternating extension and compression forces over the long-term, to which we added a special hydraulic module. Using the multimedia technology we achieved a real time superimposition of the volume-diameter curve on the balloon. The function of the testing device and method is demonstrated on dilatation catheters. Our initial results reveal compatibility with the requirements of the 1% accuracy class. Use of this methodology for comparative testing of catheters and quality evaluation is recommended.

  11. Life-threatening urethral hemorrhage after placement of a Foley catheter in a patient with uroseptic disseminated intravascular coagulation due to chronic urinary retention induced by untreated benign prostatic hyperplasia.

    PubMed

    Ikegami, Yukihiro; Yoshida, Keisuke; Imaizumi, Tsuyoshi; Isosu, Tsuyoshi; Kurosawa, Shin; Murakawa, Masahiro

    2016-10-01

    A 77-year-old man with severe septic disseminated intravascular coagulation following urinary infection was transported to our hospital. He had developed urinary retention induced by untreated prostatic hyperplasia. Immediate drainage with a Foley catheter was successfully carried out, but the hematuria progressed to life-threatening hemorrhage. Complete hemostasis was impossible by surgical treatment because the tissue around the prostatic urethra was very fragile and hemorrhagic. Organized treatments (continuous hemodiafiltration combined with polymyxin-B immobilized fiber column hemoperfusion and systemic treatment with antibiotics and coagulation factors) were commenced soon after the operation. The patient eventually recovered from the septic disseminated intravascular coagulation. This case report illustrates the risk of placement of Foley catheters in patients with severe septic disseminated intravascular coagulation.

  12. Foley catheter for cervical priming in induction of labour at University Obstetrics Unit, Colombo, Sri Lanka: a clinical audit with a patient satisfaction survey.

    PubMed

    Patabendige, M; Jayawardane, A

    2017-04-12

    Intracervical insertion of a Foley catheter (FC) has shown to be a safe, effective and relatively feasible mechanical method of cervical priming in induction of labour (IOL). We evaluated indications, effectiveness, patient acceptability and outcomes of FC use in IOL adhering to the ward protocol in our unit. A clinical audit with a patient satisfaction survey conducted between July and September 2013 in University Obstetric Unit, Colombo, Sri Lanka. Patients selected for IOL for obstetric reasons were primed with Foley as per ward protocol. All had singleton pregnancies with cephalic presentation, intact membranes and period of gestation of 37 weeks or above. Women with a history of more than one caesarean section or uterine surgery, low-lying placenta and fetal growth restriction were excluded. Subjects who had a Modified Bishop Score (MBS) of less than 3, a 16Fr FC was inserted into cervical canal. Catheter was left undisturbed until spontaneous expulsion or no longer than 48 h. In women with MBS of less than 6 at 48 h after FC insertion, 3 mg prostaglandin E2 vaginal tablet was used subsequently. Artificial membrane rupture with or without oxytocin was used if MBS of 6 or more and in women not in labour 24 h after prostaglandins. Patient satisfaction for Foley insertion was assessed with regards to the degree of comfort using a validated visual analogue scale (0-10). There were a total of 910 deliveries during the study period. Fifty-six women were primed with FC. Thirty-two (57%) were nulliparous. During induction of labour, 53(95%) reported mild or no discomfort. MBS of 6 or more was achieved in 36/56 (64%) Foley insertions. Twenty needed further intervention with prostaglandins. FC only group had 5 caesarean sections and 31 vaginal deliveries and Foley/prostaglandin group had 7 caesarean sections and 13 vaginal deliveries. Of the 24 women who were induced due to completion of 41 weeks of gestation with otherwise uncomplicated pregnancies, 17 had MBS >6

  13. Stability and Agreement of a Microtransducer and an Air-Filled Balloon Esophageal Catheter in the Monitoring of Esophageal Pressure.

    PubMed

    Augusto, Renan Maloni; Albuquerque, André Luis Pereira; Jaeger, Thomas; de Carvalho, Carlos Roberto Ribeiro; Caruso, Pedro

    2017-02-01

    The use of esophageal catheters with microtransducer promises advantages over traditional catheters with air-filled balloons. However, performance comparisons between these 2 types of catheters are scarce and incomplete. A catheter with a 9.5-cm air-filled balloon at the distal tip and a catheter with a microtransducer mounted within a flexible silicone rubber were tested in vitro and in vivo. In vitro, the response times of both catheters were compared, and the drift of the baseline pressure of the microtransducer catheter was evaluated over a 6-h period. In vivo, 11 healthy volunteers had both catheters inserted, and the drift of the baseline esophageal pressure was measured over a 3-h period. Also, the correlation and agreement of the baseline and changes in the esophageal pressure of both catheters were evaluated. In vitro, the microtransducer catheter had a response time significantly higher (262 × 114 Hz, P < .01) and a good pressure stability, with a mean baseline pressure drift of 1.4 cm H 2 O. In vivo, both catheters presented a small and similar baseline esophageal pressure drift (P = 0.08). For measurements of baseline and changes in esophageal pressure, the correlation and agreement between the catheters were poor, with a large bias between them. The catheter with the microtransducer had a small baseline pressure drift, similar to the air-filled balloon catheter. The low agreement between the catheters does not allow the microtransducer catheter to be used as a surrogate for the traditional air-filled balloon catheter. Copyright © 2017 by Daedalus Enterprises.

  14. Aortic occlusion balloon catheter technique is useful for uncontrollable massive intraabdominal bleeding after hepato-pancreato-biliary surgery.

    PubMed

    Miura, Fumihiko; Takada, Tadahiro; Ochiai, Takenori; Asano, Takehide; Kenmochi, Takashi; Amano, Hodaka; Yoshida, Masahiro

    2006-04-01

    Massive intraabdominal hemorrhage sometimes requires urgent hemostatic surgical intervention. In such cases, its rapid stabilization is crucial to reestablish a general hemodynamic status. We used an aortic occlusion balloon catheter in patients with massive intraabdominal hemorrhage occurring after hepato-pancreato-biliary surgery. An 8-French balloon catheter was percutaneously inserted into the aorta from the femoral artery, and the balloon was placed just above the celiac artery. Fifteen minutes inflation and 5 minutes deflation were alternated during surgery until the bleeding was surgically controlled. An aortic occlusion balloon catheter was inserted on 13 occasions in 10 patients undergoing laparotomy for hemostasis of massive hemorrhage. The aorta was successfully occluded on 12 occasions in nine patients. Both systolic pressure and heart rate were normalized during aortic occlusion, and the operative field became clearly visible after adequate suction of leaked blood. Bleeding sites were then easily found and controlled. Hemorrhage was successfully controlled in 7 of 10 patients (70%), and they were discharged in good condition. The aortic occlusion balloon catheter technique was effective for easily controlling massive intraabdominal bleeding by hemostatic procedure after hepato-pancreato-biliary surgery.

  15. Double balloon catheter for induction of labour in Chinese women with previous caesarean section: one-year experience and literature review.

    PubMed

    Cheuk, Queenie K Y; Lo, T K; Lee, C P; Yeung, Anita P C

    2015-06-01

    To evaluate the efficacy and safety of double balloon catheter for induction of labour in Chinese women with one previous caesarean section and unfavourable cervix at term. Retrospective cohort study. A regional hospital in Hong Kong. Women with previous caesarean delivery requiring induction of labour at term and with an unfavourable cervix from May 2013 to April 2014. Primary outcome was to assess rate of successful vaginal delivery (spontaneous or instrument-assisted) using double balloon catheter. Secondary outcomes were double balloon catheter induction-to-delivery and removal-to-delivery interval; cervical score improvement; oxytocin augmentation; maternal or fetal complications during cervical ripening, intrapartum and postpartum period; and risk factors associated with unsuccessful induction. All 24 Chinese women tolerated double balloon catheter well. After double balloon catheter expulsion or removal, the cervix successfully ripened in 18 (75%) cases. The improvement in Bishop score 3 (interquartile range, 2-4) was statistically significant (P<0.001). Overall, 18 (75%) cases were delivered vaginally. The median insertion-to-delivery and removal-to-delivery intervals were 19 (interquartile range, 13.4-23.0) hours and 6.9 (interquartile range, 4.1-10.8) hours, respectively. Compared with cases without, the interval to delivery was statistically significantly shorter in those with spontaneous balloon expulsion or spontaneous membrane rupture during ripening (7.8 vs 3.0 hours; P=0.025). There were no major maternal or neonatal complications. The only factor significantly associated with failed vaginal birth after caesarean was previous caesarean section for failure to progress (P<0.001). This is the first study using double balloon catheter for induction of labour in Asian Chinese women with previous caesarean section. Using double balloon catheter, we achieved a vaginal birth after caesarean rate of 75% without major complications.

  16. Liquid- and Air-Filled Catheters without Balloon as an Alternative to the Air-Filled Balloon Catheter for Measurement of Esophageal Pressure

    PubMed Central

    Carvalho, Alysson R.; Zin, Walter Araujo; Carvalho, Nadja C.; Huhle, Robert; Giannella-Neto, Antonio; Koch, Thea; de Abreu, Marcelo Gama

    2014-01-01

    Background Measuring esophageal pressure (Pes) using an air-filled balloon catheter (BC) is the common approach to estimate pleural pressure and related parameters. However, Pes is not routinely measured in mechanically ventilated patients, partly due to technical and practical limitations and difficulties. This study aimed at comparing the conventional BC with two alternative methods for Pes measurement, liquid-filled and air-filled catheters without balloon (LFC and AFC), during mechanical ventilation with and without spontaneous breathing activity. Seven female juvenile pigs (32–42 kg) were anesthetized, orotracheally intubated, and a bundle of an AFC, LFC, and BC was inserted in the esophagus. Controlled and assisted mechanical ventilation were applied with positive end-expiratory pressures of 5 and 15 cmH2O, and driving pressures of 10 and 20 cmH2O, in supine and lateral decubitus. Main Results Cardiogenic noise in BC tracings was much larger (up to 25% of total power of Pes signal) than in AFC and LFC (<3%). Lung and chest wall elastance, pressure-time product, inspiratory work of breathing, inspiratory change and end-expiratory value of transpulmonary pressure were estimated. The three catheters allowed detecting similar changes in these parameters between different ventilation settings. However, a non-negligible and significant bias between estimates from BC and those from AFC and LFC was observed in several instances. Conclusions In anesthetized and mechanically ventilated pigs, the three catheters are equivalent when the aim is to detect changes in Pes and related parameters between different conditions, but possibly not when the absolute value of the estimated parameters is of paramount importance. Due to a better signal-to-noise ratio, and considering its practical advantages in terms of easier calibration and simpler acquisition setup, LFC may prove interesting for clinical use. PMID:25247308

  17. Liquid- and air-filled catheters without balloon as an alternative to the air-filled balloon catheter for measurement of esophageal pressure.

    PubMed

    Beda, Alessandro; Güldner, Andreas; Carvalho, Alysson R; Zin, Walter Araujo; Carvalho, Nadja C; Huhle, Robert; Giannella-Neto, Antonio; Koch, Thea; de Abreu, Marcelo Gama

    2014-01-01

    Measuring esophageal pressure (Pes) using an air-filled balloon catheter (BC) is the common approach to estimate pleural pressure and related parameters. However, Pes is not routinely measured in mechanically ventilated patients, partly due to technical and practical limitations and difficulties. This study aimed at comparing the conventional BC with two alternative methods for Pes measurement, liquid-filled and air-filled catheters without balloon (LFC and AFC), during mechanical ventilation with and without spontaneous breathing activity. Seven female juvenile pigs (32-42 kg) were anesthetized, orotracheally intubated, and a bundle of an AFC, LFC, and BC was inserted in the esophagus. Controlled and assisted mechanical ventilation were applied with positive end-expiratory pressures of 5 and 15 cmH2O, and driving pressures of 10 and 20 cmH2O, in supine and lateral decubitus. Cardiogenic noise in BC tracings was much larger (up to 25% of total power of Pes signal) than in AFC and LFC (<3%). Lung and chest wall elastance, pressure-time product, inspiratory work of breathing, inspiratory change and end-expiratory value of transpulmonary pressure were estimated. The three catheters allowed detecting similar changes in these parameters between different ventilation settings. However, a non-negligible and significant bias between estimates from BC and those from AFC and LFC was observed in several instances. In anesthetized and mechanically ventilated pigs, the three catheters are equivalent when the aim is to detect changes in Pes and related parameters between different conditions, but possibly not when the absolute value of the estimated parameters is of paramount importance. Due to a better signal-to-noise ratio, and considering its practical advantages in terms of easier calibration and simpler acquisition setup, LFC may prove interesting for clinical use.

  18. Entrapment of guide-wire during oesophageal dilation.

    PubMed

    Misra, S P; Dwivedi, M

    1997-01-01

    We report a patient who developed oesophageal stricture after accidental ingestion of acid. During one of the oesophageal dilation sessions, a Savary-Gillard guide-wire got entrapped in the stomach and had to be removed surgically. A Foley catheter, placed for feeding purposes, migrated into the proximal small intestine causing acute intestinal obstruction. The balloon of the Foley catheter had to be punctured using a sclerotherapy needle and the catheter withdrawn.

  19. Foley Plus Oxytocin Compared With Oxytocin for Induction After Membrane Rupture: A Randomized Controlled Trial.

    PubMed

    Mackeen, A Dhanya; Durie, Danielle E; Lin, Monique; Huls, Christopher K; Qureshey, Emma; Paglia, Michael J; Sun, Haiyan; Sciscione, Anthony

    2018-01-01

    To evaluate the use of a transcervical Foley catheter plus oxytocin infusion compared with oxytocin infusion alone for labor induction and cervical ripening in women 34 weeks of gestation or greater with prelabor rupture of membranes. This is a randomized, multicenter trial of women with a live, singleton gestation at 34 weeks of gestation or greater with prelabor rupture of membranes, an unfavorable cervical examination (less than 2 cm or 80% effaced), and no contraindication to labor. Participants were randomly allocated to a transcervical Foley catheter inflated to 30 cc with concurrent oxytocin infusion or oxytocin infusion alone. Oxytocin administration was standardized across sites. The primary study outcome was interval from induction to delivery. To detect a 2.5-hour difference in the interval from induction to delivery, we required outcome data on 194 women, assuming 80% power and a two-tailed α of 5%. Analysis was by intent to treat. We enrolled 201 women: 93 were allocated to Foley and 108 to oxytocin. Demographics were similar between the groups. Time to delivery was not significantly different between groups: in the Foley group, it was 13.9 hours (±6.9 SD) compared with 14.4 hours (±7.9 SD) in the oxytocin group (P=.69). There were more cases of clinical chorioamnionitis (8% compared with 0%, P<.01) in the Foley group compared with the oxytocin group. There were no differences for other infectious morbidities or any other variable studied. In patients with prelabor rupture of membranes, the use of a transcervical Foley catheter in addition to oxytocin does not shorten the time to delivery compared with oxytocin alone, but may increase the incidence of intraamniotic infection. ClinicalTrials.gov, NCT01973036.

  20. Prophylactic use of intravascular balloon catheters in women with placenta accreta, increta and percreta.

    PubMed

    Cali, Giuseppe; Forlani, Francesco; Giambanco, Laura; Amico, Maria Luisa; Vallone, Mario; Puccio, Giuseppe; Alio, Luigi

    2014-08-01

    To evaluate outcomes of women undergoing cesarean hysterectomy for abnormal invasive placenta (AIP) with and without preoperative balloon catheter placement in internal iliac arteries. A prospective observational study of women with ultrasound diagnosis of AIP and a planned delivery at our institution. From January 2004 to June 2009, all AIP cases were treated with planned multidisciplinary cesarean hysterectomy alone (CHa group). From July 2009 to September 2013 a pre-operative balloon catheter protocol was introduced (BC group). Statistical analysis considered the entire sample (placenta accreta/increta and percreta) and the individual subgroups (accreta/increta vs percreta). Twenty-three cases of AIP (10 accreta/increta and 13 percreta) were treated with cesarean hysterectomy alone, and 30 cases of AIP (12 accreta/increta and 18 percreta) were treated with cesarean hysterectomy and pre-operative balloon catheters. For the entire sample, a significant difference in estimated blood loss and transfused blood products units was observed between CHa group and BC group. When women with placenta accreta/increta and women with placenta percreta were analysed separately, no difference in estimated blood loss and transfused blood products units was found between the BC and the CHa groups in women with placenta accreta/increta. However, in women with placenta percreta, mean estimated blood loss and transfused blood products units were higher in the CHa group compared with BC group (1507ml vs 933.33ml; 3.31 units vs 0.67 units). Postoperative recovery differed between the two groups, but no differences were observed in any other outcomes. Pre-operative placement of intravascular balloon catheters is a feasible treatment for AIP, and is particularly useful in cases of placenta percreta. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  1. First-in-human experience using the Volcano VIBE-RX vascular imaging balloon catheter system (Volcano IVUS-guided Balloon Evaluation - New Zealand: VIBE-NZ Study).

    PubMed

    Watson, Timothy; El-Jack, Seifeddin; Stewart, James T; Ormiston, John

    2013-09-01

    Intravascular ultrasound (IVUS) is a proven and safe imaging modality used to guide percutaneous coronary intervention (PCI). The Volcano VIBE™ RX Vascular Imaging Balloon Catheter is a novel rapid exchange, 0.014" wire-compatible multi-lumen conventional balloon catheter modified with the addition of an IVUS transducer proximal to the balloon, delivered via a standard 6 Fr sheath. We sought to evaluate the safety, balloon performance, and image quality of the VIBE™ RX in patients scheduled for coronary intervention. Patients aged >21 and <85 years with single or multivessel coronary disease scheduled for PCI due to coronary ischaemic symptoms were included. Those with angiographic features that precluded the safe or informative use of the device were excluded. Twenty-nine patients having angiography because of ischaemic symptoms underwent 44 VIBE RX imaging runs, with balloon dilation in 20. Successful device deployment was achieved in all but one patient. All images were adequate and reproducible. One patient had a non-ST-elevation MI felt to be due to the complexity of the procedure rather than directly related to the VIBE™ RX. The study demonstrated the safety and effectiveness of the VIBE™ RX for its intended purpose with minimal failure rate and no directly related complications.

  2. Image-Guided High-Dose Rate Brachytherapy in Cervix Carcinoma Using Balloon Catheter and Belt Immobilization System.

    PubMed

    Fan, Qiyong; Yeung, Anamaria R; Amdur, Robert; Helmig, Richard; Park, Justin; Li, Jonathan; Kahler, Darren; Liu, Chihray; Lu, Bo

    2017-06-01

    The efficacy of image-guided high-dose rate brachytherapy for cervical cancer is limited by the ineffective rectal sparing devices available commercially and the potential applicator movement. We developed a novel device using a balloon catheter and a belt immobilization system, serving for rectal dose reduction and applicator immobilization purposes, respectively. The balloon catheter is constructed by gluing a short inflatable tube to a long regular open-end catheter. Contrast agent (10) cm 3 is injected into the inflatable end, which is affixed to the tandem and ring applicator, to displace the posterior vaginal wall. The belt immobilization system consists of a specially designed bracket that can hold and fix itself to the applicator, a diaper-like Velcro fastener package used for connecting the patient's pelvis to the bracket, and a buckle that holds the fasteners to stabilize the whole system. The treatment data for 21 patients with cervical cancer using both balloon catheter and belt immobilization system were retrospectively analyzed. Computed tomography and magnetic resonance images, acquired about 30 minutes apart, were registered to evaluate the effectiveness of the immobilization system. In comparison with a virtual rectal blade, the balloon decreased the rectal point dose by 34% ± 4.2% (from 276 ± 57 to 182 ± 38 cGy), corresponding to an extra sparing distance of 7.9 ± 1.1 mm. The maximum sparing distance variation per patient is 1.4 ± 0.6 mm, indicating the high interfractional reproducibility for rectum sparing. With the immobilization system, the mean translational and rotational displacements of the applicator set are <3 mm and <1.5°, respectively, in all directions. The rectal balloon provides significant dose reduction to the rectum and it may potentially minimize patient discomfort. The immobilization system permits almost no movement of the applicator during treatment. This work has the potential to be promoted as a standardized solution

  3. Misdiagnoses caused by use of indwelling urethral catheters in children with ureterovesical junction anomalies.

    PubMed

    Çelebi, Süleyman; Sander, Serdar; Kuzdan, Özgür; Özaydın, Seyithan; Güvenç, Ünal; Yavuz, Sevgi; Kıyak, Aysel; Demirali, Oyhan

    2015-04-01

    Children commonly undergo vesicograms for diagnosing vesicoureteral reflux (VUR). This requires urethral catheterization with transurethral replacement. We report misdiagnosed or related complications due to indwelling urethral catheters unintentionally placed in the ureter. From our computerized urology records over an 18-year period from January 1995 to May 2013, we retrospectively identified nine cases of 1850 vesicograms that had misdirection of a urethral catheter placed in a ureter. Foley catheters with inflating balloons were used to obtain the vesicograms. In all, 1850 vesicograms were performed (746 males, 1104 females; age 1 week to 14 years, mean age 3.8 years) using standard radiological techniques. Size 6-10 Fr indwelling urethral catheters were used, depending on the patient's age and gender. In nine cases (five females, four males), a misdirected urethral catheter was discovered in one of the ureters. The urethral catheter was in the left ureter in four patients and in the right ureter in five patients. Cystoscopic examination found ectopic ureteral openings in six patients: at the bladder neck in four and just below the bladder trigone in two. Three patients in this group with ectopic ureters were followed due a misdiagnosis of VUR. The remaining three patients had grade 3 or 4 VUR. In this group, the catheter passed into the ureter because of the enlarged ureterovesical junction. In one patient with VUR, intraparenchymal fluid leakage and transient hematuria occurred due to the rapid tension increase following the fast injection of contrast with liquid to one ureter. Although placing an indwelling urethral catheter is a relatively safe procedure, complications can occur, particularly in patients with ureterovesical anomalies, such as high-grade VUR or an ectopic ureter. Using catheters with inflating balloons can cause rapid increases in tension in the ureter, and related complications.

  4. Delivery of Plasmid DNA to Vascular Tissue in vivo using Catheter Balloons Coated with Polyelectrolyte Multilayers

    PubMed Central

    Saurer, Eric M.; Yamanouchi, Dai; Liu, Bo; Lynn, David M.

    2010-01-01

    We report an approach for the localized delivery of plasmid DNA to vascular tissue from the surfaces of inflatable embolectomy catheter balloons. Using a layer-by-layer approach, ultrathin multilayered polyelectrolyte films were fabricated on embolectomy catheter balloons by alternately adsorbing layers of a hydrolytically degradable poly(β-amino ester) and plasmid DNA. Fluorescence microscopy revealed that the films coated the surfaces of the balloons uniformly. Coated balloons that were incubated in phosphate-buffered saline at 37 °C released ~25 μg DNA/cm2 over 24 hours. Analysis of the DNA by gel electrophoresis showed that the DNA was released in open-circular (‘nicked’) and supercoiled conformations, and in vitro cell transfection assays confirmed that the released DNA was transcriptionally active. Arterial injury was induced in the internal carotid arteries of Sprague-Dawley rats using uncoated balloons, followed by treatment with film-coated balloons for 20 minutes. X-gal, immunohistochemical, and immunofluorescence staining of sectioned arteries indicated high levels of β-galactosidase or enhanced green fluorescent protein (EGFP) expression in arteries treated with film-coated balloons. β-galactosidase and EGFP expression were observed throughout the medial layers of arterial tissue, and around approximately two-thirds of the circumference of the treated arteries. The layer-by-layer approach reported here provides a general platform for the balloon-mediated delivery of DNA to vascular tissue. Our results suggest the potential of this approach to deliver therapeutically relevant DNA to prevent complications such as intimal hyperplasia that arise after vascular interventions. PMID:20933275

  5. Retrograde endopyelotomy: a comparison between laser and Acucise balloon cutting catheter.

    PubMed

    el-Nahas, Ahmed R

    2007-03-01

    Endopyelotomy and laparoscopic pyeloplasty are the preferred modalities for treatment of ureteropelvic junction obstruction because of their minimally invasive nature. There are continuous efforts for improving endopyelotomy techniques and outcome. Retrograde access represents the natural evolution of endopyelotomy. The Acucise cutting balloon catheter (Applied Medical Resources Corp., Laguna Hills, CA) and ureteroscopic endopyelotomy using holmium laser are the most widely accepted techniques. The Acucise catheter was developed to simplify retrograde endopyelotomy and made it possible for all urologists, regardless of their endourologic skills. The Acucise catheter depends on incision and dilatation of the ureteropelvic junction under fluoroscopic guidance, whereas ureteroscopy allows visual control of the site, depth, and extent of the incision; the holmium laser is a perfect method for a clean precise incision. Review of the English literature showed that the Acucise technique was more widely performed, though laser had better (but not statistically significant) safety and efficacy profiles.

  6. Balloon-Assisted Chemoembolization Using a Micro-Balloon Catheter Alongside a Microcatheter for a Hepatocellular Carcinoma with a Prominent Arterioportal Shunt: A Case Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hoshiai, Sodai, E-mail: hoshiai@sb4.so-net.ne.jp; Mori, Kensaku; Ishiguro, Toshitaka

    Although transcatheter arterial chemoembolization is one of the established treatments for hepatocellular carcinoma (HCC), it is difficult to treat HCCs with prominent arterioportal (AP) shunts because anticancer drugs and embolic materials migrate into the non-tumorous liver through the AP shunts and may cause liver infarction. We developed a novel method of balloon-assisted chemoembolization using a micro-balloon catheter alongside a microcatheter simultaneously inserted through a single 4.5-Fr guiding sheath, comprising proximal chemoembolization with distal arterial balloon occlusion. We applied this method to treat an HCC with a prominent distal AP shunt induced by previous proton beam therapy and achieved successful chemoembolizationmore » without non-tumorous liver infarction under temporal balloon occlusion of a distal AP shunt.« less

  7. Materials for multifunctional balloon catheters with capabilities in cardiac electrophysiological mapping and ablation therapy

    NASA Astrophysics Data System (ADS)

    Kim, Dae-Hyeong; Lu, Nanshu; Ghaffari, Roozbeh; Kim, Yun-Soung; Lee, Stephen P.; Xu, Lizhi; Wu, Jian; Kim, Rak-Hwan; Song, Jizhou; Liu, Zhuangjian; Viventi, Jonathan; de Graff, Bassel; Elolampi, Brian; Mansour, Moussa; Slepian, Marvin J.; Hwang, Sukwon; Moss, Joshua D.; Won, Sang-Min; Huang, Younggang; Litt, Brian; Rogers, John A.

    2011-04-01

    Developing advanced surgical tools for minimally invasive procedures represents an activity of central importance to improving human health. A key challenge is in establishing biocompatible interfaces between the classes of semiconductor device and sensor technologies that might be most useful in this context and the soft, curvilinear surfaces of the body. This paper describes a solution based on materials that integrate directly with the thin elastic membranes of otherwise conventional balloon catheters, to provide diverse, multimodal functionality suitable for clinical use. As examples, we present sensors for measuring temperature, flow, tactile, optical and electrophysiological data, together with radiofrequency electrodes for controlled, local ablation of tissue. Use of such ‘instrumented’ balloon catheters in live animal models illustrates their operation, as well as their specific utility in cardiac ablation therapy. The same concepts can be applied to other substrates of interest, such as surgical gloves.

  8. [Application of injection test in confirming the ideal position of esophageal balloon catheter].

    PubMed

    Chen, Han; Xu, Ming; Yang, Yanlin; He, Xuan; Zhou, Jianxin

    2017-09-01

    To evaluate the safety and feasibility of injection test which is used to locate esophageal balloon catheter. A prospective study was conducted. The patients undergoing invasive mechanical ventilation (MV) admitted to general intensive care unit (ICU) of Beijing Tiantan Hospital Affiliated to Capital Medical University from May 2015 and March 2017 were enrolled. The commercially available esophageal balloon catheter was modified to perform injection test. The catheter was withdrawn step by step and the injection test was repeated until the presence disturbance wave presented, which indicated that the balloon had just entered the esophagus. The position where disturbance wave appears was named 0 cm. End-expiratory occlusions were performed at the positions of +15, +10, +5, 0, -5, -10 and -15 cm, respectively, and the changes of esophageal pressure (Pes) and airway pressures (Paw) were measured in the spontaneous breathing and passive ventilation, and the ratio between the changes (ΔPes/ΔPaw) was calculated. A total of 20 patients were enrolled, of which 15 patients finished both the spontaneous and the passive ventilation parts, and 2 patients finished only the spontaneous part and 3 patients finished only passive part. (1) Disturbance waves could be induced by injection test in all patients. The average depth of disturbance wave in spontaneous breathing was deeper than that in passive ventilation (cm: 42.4±3.8 vs. 41.8±3.3), but there was no significant difference between the two ventilation settings (P = 0.132). No adverse events occurred during the study period. (2) Pes increased with the stepwise withdraw of esophageal catheter, reached the maximal value at +5 cm, and then decreased when the catheter was further withdrawn, no matter in the spontaneous or the passive ventilation. In spontaneous breathing, the ΔPes/ΔPaw was within the ideal range (0.8-1.2) at the positions of 0, -5 and -10 cm. The ΔPes/ΔPaw was closest to unity at the positions of 0 cm (0

  9. Angioplasty balloon catheters used for distraction of the ankle joint.

    PubMed

    Sartoretti, C; Sartoretti-Schefer, S; Duff, C; Buchmann, P

    1996-02-01

    Arthroscopy of the ankle joint is now routinely performed in diagnostic and therapeutic interventions but is still a demanding and difficult operative procedure in this very small and tight joint. Arthroscopy can be facilitated by a sufficient distraction that gives a better overview of the joint space. However, it is still a matter of debate how to obtain the adequate distraction. Distention by manual strength as well as by the help of a technical device have been proposed. We report our experience with distraction of the ankle joint by the help of one or two intraarticularily located and secondarily insufflated angioplasty balloon catheters that are routinely used in interventional radiology. These special catheters allow a careful and controlled distention of the joint with a fixed space of distraction and, according to our limited experience, without any morbidity.

  10. [A clinical observation of percutaneous balloon dilation and maintenance percutaneous transhepatic cholangial catheter drainage for treatment of 21 patients with benign biliary strictures and difficult endoscopy].

    PubMed

    Pan, Jie; Shi, Hai-feng; Li, Xiao-guang; Zhang, Xiao-bo; Liu, Wei; Jin, Zheng-yu; Hong, Tao; Yang, Ai-ming; Yang, Ning

    2012-06-01

    To investigate the value of percutaneous balloon dilation and percutaneous transhepatic cholangial drainage (PTCD) catheter maintenance in the treatment of benign biliary strictures. The clinical data of 21 patients with benign biliary strictures at Peking Union Medical College Hospital from June 2005 to June 2011 were retrospectively studied, in which 12 patients in severe stricture (stenosis > 70%) were treated with percutaneous balloon dilation and PTCD catheter placed across the stricture, while another 9 patients in median stricture (stenosis < 70%) were only treated with PTCD catheter maintenance. Of the 12 patients underwent balloon dilation and 6 - 12 months (median: 9 months) of PTCD catheter placement, 11 patients had the catheter successfully removed. In the follow-up of 6 - 24 months (median: 10 months), patency of bile duct was preserved in 9 of 11 patients, and recurrent stenosis was seen in 2 patients. A severe complication with biliary artery branch rupture and massive hemobilia was seen in 1 patient during balloon dilation. Of the 9 patients only treated with 1 - 12 months (median: 6 months) of PTCD catheter placement, 7 patients had the catheter successfully removed. In the follow-up of 5 - 18 months (median: 8 months), patency of bile duct was preserved in 5 of 7 patients, and recurrent stenosis was seen in 2 patients. No severe complication occurred. When endoscopy therapy is failed or the patient can't undergo endoscopy therapy, the percutaneous balloon dilation and PTCD catheter maintenance method is an effective alternative therapeutic approach in the treatment of benign biliary strictures. The moderate benign biliary stricture may be effectively treated only by the PTCD catheter maintenance method.

  11. Urinary catheters: history, current status, adverse events and research agenda

    PubMed Central

    Feneley, Roger C. L.; Hopley, Ian B.; Wells, Peter N. T.

    2015-01-01

    Abstract For more than 3500 years, urinary catheters have been used to drain the bladder when it fails to empty. For people with impaired bladder function and for whom the method is feasible, clean intermittent self-catheterization is the optimal procedure. For those who require an indwelling catheter, whether short- or long-term, the self-retaining Foley catheter is invariably used, as it has been since its introduction nearly 80 years ago, despite the fact that this catheter can cause bacterial colonization, recurrent and chronic infections, bladder stones and septicaemia, damage to the kidneys, the bladder and the urethra, and contribute to the development of antibiotic resistance. In terms of medical, social and economic resources, the burden of urinary retention and incontinence, aggravated by the use of the Foley catheter, is huge. In the UK, the harm resulting from the use of the Foley catheter costs the National Health Service between £1.0–2.5 billion and accounts for ∼2100 deaths per year. Therefore, there is an urgent need for the development of an alternative indwelling catheter system. The research agenda is for the new catheter to be easy and safe to insert, either urethrally or suprapubically, to be retained reliably in the bladder and to be withdrawn easily and safely when necessary, to mimic natural physiology by filling at low pressure and emptying completely without damage to the bladder, and to have control mechanisms appropriate for all users. PMID:26383168

  12. Usefulness of the low profile "True 8" intra-aortic balloon pumping catheter for preventing limb lschemia.

    PubMed

    Kuki, S; Taniguchi, K; Masai, T; Yoshida, K; Yamamoto, K; Matsuda, H

    2001-01-01

    The most important limitation in the use of an intra-aortic balloon pumping (IABP) is the risk of vascular complications. Recently, an IABP catheter with an 8.0 French shaft and low profile that may decrease the risk of vascular morbidity has been developed. We evaluated the in vitro balloon performance and the prevention of limb ischemia in clinical use. An 8.0 French IABP catheter was compared with a standard 9.5 French catheter. Inflation time (IT), deflation time (DT), and changes in volume (V) generated by the balloon were measured during the pumping cycle in an experimental model. The inflation velocity (V/IT) and deflation velocity (V/DT) were calculated as parameters of balloon performance. At 120 bpm the V/IT and V/DT were 0.34 ml/msec and 0.28 ml/msec with the 8.0 French, and 0.33 ml/msec and 0.24 ml/msec with the 9.5 French catheter. Twelve patients with coronary artery disease, ranging in age from 41 to 87 years (mean, 66 years), who underwent IABP support, were divided into group 1 (8.0 French, n = 4) and group 2 (9.5 French, n = 8). Ankle-arm pressure index (API), lactate extraction ratio (LER) in the limb with IABP insertion, and cardiac index (CI) were measured at 1, 12, and 24 hours postoperatively. There were no major vascular complications and no counterpulsation related morbidity. There was no significant difference between the two groups with regard to age, duration of IABP support, and incidence of peripheral vascular disease and diabetes. The percentage of women patients was significantly higher in group 1 (100% vs. 25%), whereas body surface area was significantly smaller (1.45 +/- 0.14 vs. 1.68 +/- 0.12 m2). The API in group 1 were slightly higher than those in group 2 throughout the observed period (not significant). The LER and Cl showed no significant differences between the two groups. These results suggest that the 8.0 French IABP catheter with a low profile has an acceptable in vitro performance, and its clinical application may be

  13. Feasibility and Safety of Distal and Proximal Combined Endovascular Approach with a Balloon-Guiding Catheter for Subclavian Artery Total Occlusion.

    PubMed

    Yamamoto, Taiki; Ohshima, Tomotaka; Ishikawa, Kojiro; Goto, Shunsaku; Tamari, Yosuke

    2017-04-01

    Symptomatic subclavian artery total occlusion is widely treated with an endovascular procedure that often results in distal vertebral artery embolism. Therefore, protection devices are important. Establishing a filter or balloon device in the vertebral artery can protect against this distal embolism. However, the use of embolic protection devices is not easy, and it makes the procedure more complicated. Here, we report a case of symptomatic subclavian artery total occlusion that was treated successfully with a balloon-guiding catheter and the pull-through technique. A 67-year-old man developed intermittent motor weakness in his left arm. Aortic angiography demonstrated a complete occlusion of the left proximal subclavian artery and a retrograde flow through the left vertebral artery to the distal brachial artery. In this case, we used a balloon-guiding catheter and the pull-through technique to prevent distal embolism. The balloon-guiding system was useful not only for embolic protection but also for scaffold during excavation and for the centering effect against invisible vessels. The pull-through technique enabled our devices to deliver easily and smoothly. The patient was treated successfully without complications. The distal and proximal combined endovascular treatment with a transbrachial balloon-guiding catheter is a beneficial treatment option for patients with subclavian artery total occlusion. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. Circumferential optical coherence tomography angiography imaging of the swine esophagus using a micromotor balloon catheter.

    PubMed

    Lee, Hsiang-Chieh; Ahsen, Osman Oguz; Liang, Kaicheng; Wang, Zhao; Cleveland, Cody; Booth, Lucas; Potsaid, Benjamin; Jayaraman, Vijaysekhar; Cable, Alex E; Mashimo, Hiroshi; Langer, Robert; Traverso, Giovanni; Fujimoto, James G

    2016-08-01

    We demonstrate a micromotor balloon imaging catheter for ultrahigh speed endoscopic optical coherence tomography (OCT) which provides wide area, circumferential structural and angiographic imaging of the esophagus without contrast agents. Using a 1310 nm MEMS tunable wavelength swept VCSEL light source, the system has a 1.2 MHz A-scan rate and ~8.5 µm axial resolution in tissue. The micromotor balloon catheter enables circumferential imaging of the esophagus at 240 frames per second (fps) with a ~30 µm (FWHM) spot size. Volumetric imaging is achieved by proximal pullback of the micromotor assembly within the balloon at 1.5 mm/sec. Volumetric data consisting of 4200 circumferential images of 5,000 A-scans each over a 2.6 cm length, covering a ~13 cm(2) area is acquired in <18 seconds. A non-rigid image registration algorithm is used to suppress motion artifacts from non-uniform rotational distortion (NURD), cardiac motion or respiration. En face OCT images at various depths can be generated. OCT angiography (OCTA) is computed using intensity decorrelation between sequential pairs of circumferential scans and enables three-dimensional visualization of vasculature. Wide area volumetric OCT and OCTA imaging of the swine esophagus in vivo is demonstrated.

  15. Balloon catheter sinuplasty and adenoidectomy in children with chronic rhinosinusitis.

    PubMed

    Ramadan, Hassan H; Terrell, Andrew M

    2010-09-01

    Adenoidectomy is the first step in the surgical management of children with chronic rhinosinusitis (CRS). Adenoidectomy, however, is only effective in half of these children. Although endoscopic sinus surgery is effective for CRS, there is concern for facial growth retardation and major complications. We propose that balloon catheter sinuplasty (BCS) is a minimally invasive, effective procedure in the treatment of pediatric CRS. We undertook a nonrandomized, controlled, prospective review of children with failed medical management of CRS who underwent BCS or adenoidectomy. Outcomes were assessed at 1 year of follow-up and were based on SN-5 scores and the need for revision surgery. Forty-nine children who satisfied the inclusion criteria were reviewed. Thirty of the children had BCS. The age range was 4 to 11 years (mean, 7.7 years), and the mean computed tomography score (Lund-Mackay system) was 7.5. Twenty-four of the 30 patients (80%) who underwent BCS showed improvement of their symptoms after 12 months of follow-up, compared with 10 of the 19 patients (52.6%) who underwent adenoidectomy (p < 0.05). A multivariate analysis using logistic regression analysis with age, sex, asthma, and computed tomography score as covariables showed that BCS was also more effective than adenoidectomy in older children. None of the other variables showed statistical significance. Balloon catheter sinuplasty offers a procedure that is more effective than adenoidectomy and less invasive than endoscopic sinus surgery in the treatment of pediatric CRS.

  16. Modeling intracavitary heating of the uterus by means of a balloon catheter

    NASA Astrophysics Data System (ADS)

    Olsrud, Johan; Friberg, Britt; Rioseco, Juan; Ahlgren, Mats; Persson, Bertil R. R.

    1999-01-01

    Balloon thermal endometrial destruction (TED) is a recently developed method to treat heavy menstrual bleeding (menorrhagia). Numerical simulations of this treatment by use of the finite element method were performed. The mechanical deformation and the resulting stress distribution when a balloon catheter is expanded within the uterine cavity was estimated from structural analysis. Thermal analysis was then performed to estimate the depth of tissue coagulation (temperature > 55 degree(s)C) in the uterus during TED. The estimated depth of coagulation, after 30 min heating with an intracavity temperature of 75 degree(s)C, was approximately 9 mm when blood flow was disregarded. With uniform normal blood flow, the depth of coagulation decreased to 3 - 4 mm. Simulations with varying intracavity temperatures and blood flow rates showed that both parameters should be of major importance to the depth of coagulation. The influence of blood flow was less when the pressure due to the balloon was also considered (5 - 6 mm coagulation depth with normal blood flow).

  17. Traumatic epistaxis: Skull base defects, intracranial complications and neurosurgical considerations.

    PubMed

    Veeravagu, Anand; Joseph, Richard; Jiang, Bowen; Lober, Robert M; Ludwig, Cassie; Torres, Roland; Singh, Harminder

    2013-01-01

    Endonasal procedures may be necessary during management of craniofacial trauma. When a skull base fracture is present, these procedures carry a high risk of violating the cranial vault and causing brain injury or central nervous system infection. A 52-year-old bicyclist was hit by an automobile at high speed. He sustained extensive maxillofacial fractures, including frontal and sphenoid sinus fractures (Fig. 1). He presented to the emergency room with brisk nasopharyngeal hemorrhage, and was intubated for airway protection. He underwent emergent stabilization of his nasal epistaxis by placement of a Foley catheter in his left nare and tamponade with the Foley balloon. A six-vessel angiogram showed no evidence of arterial dissection or laceration. Imaging revealed inadvertent insertion of the Foley catheter and deployment of the balloon in the frontal lobe (Fig. 2). The balloon was subsequently deflated and the Foley catheter removed. The patient underwent bifrontal craniotomy for dural repair of CSF leak. He also had placement of a ventriculoperitoneal shunt for development of post-traumatic hydrocephalus. Although the hospital course was a prolonged one, he did make a good neurological recovery. The authors review the literature involving violation of the intracranial compartment with medical devices in the settings of craniofacial trauma. Caution should be exercised while performing any endonasal procedure in the settings of trauma where disruption of the anterior cranial base is possible. Copyright © 2013 Surgical Associates Ltd. Published by Elsevier Ltd. All rights reserved.

  18. Efficacy of Local Molsidomine Delivery from a Hydrogel-Coated Angioplasty Balloon Catheter in the Atherosclerotic Porcine Model

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rolland, Pierre H.; Mekkaoui, Choukri; Palassi, Maria

    2003-02-15

    Purpose: To evaluate the therapeutic effects of local molsidomine delivery via a hydrogel-coated angioplasty balloon catheter during overstretch angioplasty in atheroscleroticswine iliac vessels. Molsidomine is retained in the arterial wall after local delivery for more than 72 hr and is slowly metabolized intolinsidomine, releasing nitric oxide (NO). Methods: A hydrogel-coated angioplasty balloon catheter was used to both deliver drug locally (150 mg molsidomine or placebo in the contralateral vessel) and dilate iliac vessels in nine Pietrin pigs that had been on an atherogenic diet for 5 months. Animals were killed at 3 hr(n = 2), 24 hr (n = 3)more » and 3 months(n = 3) after treatment. Iliac arteries were examined for wall pulsatility, histomorphometry, cell proliferation and platelet aggregation. Results: No significant therapeutic effects were detected 3 hr after treatment. At 24 hr, wall pulsatility,thrombo resistance and vascular cell homeostasis were significantly restored in the molsidomine-treated versus placebo group. At 3 months,molsidomine inhibited restenotic lesion development, except in scarred areas of histologically detectable adventitial/medial dissection. Conclusion: Local delivery of concentrated molsidomine from a hydrogel-coated angioplasty balloon catheter resulted in early NO-dependent vasodilation/stress normalization and antithrombotic and antiproliferative effects. In the medium term, molsidomine inhibited restenosis in the absence of vessel dissection.« less

  19. Diffusing, side-firing, and radial delivery laser balloon catheters for creating subsurface thermal lesions in tissue

    NASA Astrophysics Data System (ADS)

    Chang, Chun-Hung; Fried, Nathaniel M.

    2016-02-01

    Infrared lasers have been used in combination with applied cooling methods to preserve superficial skin layers during cosmetic surgery. Similarly, combined laser irradiation and tissue cooling may also allow development of minimally invasive laser therapies beyond dermatology. This study compares diffusing, side-firing, and radial delivery laser balloon catheter designs for creation of subsurface lesions in tissue, ex vivo, using a near-IR laser and applied contact cooling. An Ytterbium fiber laser with 1075 nm wavelength delivered energy through custom built 18 Fr (6-mm-OD) balloon catheters incorporating either 10-mm-long diffusing fiber tip, 90 degree side-firing fiber, or radial delivery cone mirror, through a central lumen. A chilled solution was flowed through a separate lumen into 9-mm-diameter balloon to keep probe cooled at 7°C. Porcine liver tissue samples were used as preliminary tissue model for immediate observation of thermal lesion creation. The diffusing fiber produced subsurface thermal lesions measuring 49.3 +/- 10.0 mm2 and preserved 0.8 +/- 0.1 mm of surface tissue. The side-firing fiber produced subsurface thermal lesions of 2.4 +/- 0.9 mm2 diameter and preserved 0.5 +/- 0.1 mm of surface tissue. The radial delivery probe assembly failed to produce subsurface thermal lesions, presumably due to the small effective spot diameter at the tissue surface, which limited optical penetration depth. Optimal laser power and irradiation time measured 15 W and 100 s for diffusing fiber and 1.4 W and 20 s, for side-firing fiber, respectively. Diffusing and side-firing laser balloon catheter designs provided subsurface thermal lesions in tissue. However, the divergent laser beam in both designs limited the ability to preserve a thicker layer of tissue surface. Further optimization of laser and cooling parameters may be necessary to preserve thicker surface tissue layers.

  20. Circumferential optical coherence tomography angiography imaging of the swine esophagus using a micromotor balloon catheter

    PubMed Central

    Lee, Hsiang-Chieh; Ahsen, Osman Oguz; Liang, Kaicheng; Wang, Zhao; Cleveland, Cody; Booth, Lucas; Potsaid, Benjamin; Jayaraman, Vijaysekhar; Cable, Alex E.; Mashimo, Hiroshi; Langer, Robert; Traverso, Giovanni; Fujimoto, James G.

    2016-01-01

    We demonstrate a micromotor balloon imaging catheter for ultrahigh speed endoscopic optical coherence tomography (OCT) which provides wide area, circumferential structural and angiographic imaging of the esophagus without contrast agents. Using a 1310 nm MEMS tunable wavelength swept VCSEL light source, the system has a 1.2 MHz A-scan rate and ~8.5 µm axial resolution in tissue. The micromotor balloon catheter enables circumferential imaging of the esophagus at 240 frames per second (fps) with a ~30 µm (FWHM) spot size. Volumetric imaging is achieved by proximal pullback of the micromotor assembly within the balloon at 1.5 mm/sec. Volumetric data consisting of 4200 circumferential images of 5,000 A-scans each over a 2.6 cm length, covering a ~13 cm2 area is acquired in <18 seconds. A non-rigid image registration algorithm is used to suppress motion artifacts from non-uniform rotational distortion (NURD), cardiac motion or respiration. En face OCT images at various depths can be generated. OCT angiography (OCTA) is computed using intensity decorrelation between sequential pairs of circumferential scans and enables three-dimensional visualization of vasculature. Wide area volumetric OCT and OCTA imaging of the swine esophagus in vivo is demonstrated. PMID:27570688

  1. Arteriography of the left internal mammary artery graft utilizing a balloon-tipped floatation catheter: an alternative approach.

    PubMed

    Sharifi, M; Lauer, J; Pompili, V J; Dillon, J C

    1999-11-01

    In this report, we describe an alternative method to the conventional arteriographic techniques of the left internal mammary artery (LIMA) graft using a balloon-tipped floatation catheter placed within the left subclavian artery. The floatation catheter will serve as both an occluder of the subclavian artery as well as a port for contrast injection. It may be effectively employed in the rare instances where direct cannulation of the LIMA graft is not possible.

  2. [Clinical application of ultrasound guided Fogarty balloon catheter in arterial crisis].

    PubMed

    Li, Xiaodong; Wang, Pei; Yu, Changyu; Yan, Xiaowei; Yin, Jing

    2017-10-01

    To explore the effectiveness of arterial crisis after replantation of limb treated by ultrasound guided Fogarty balloon catheter. Between January 2012 and July 2016, 27 patients suffered from arterial crisis after replantation of limb were treated with ultrasound guided Fogarty balloon catheter combined with thrombolytic anticoagulant. There were 18 males and 9 females with the age of 19-51 years (mean, 32 years). The limb mutilation position was at knee joint in 3 cases, lower limb in 9 cases, ankle joint in 6 cases, elbow joint in 2 cases, forearm in 4 cases, and wrist joint in 3 cases. The arterial crisis happened at 2.5-18 hours (mean, 7.5 hours) after limb replantation surgery. Color doppler ultrasonography was used to diagnose the arterial thrombosis, finally the anastomotic thrombosis were found in 16 cases, non-anastomotic thrombosis in 7 cases, and combined thrombosis in 4 cases. All the thrombosis were deteced in the arteries with the length of 0.8-3.9 cm. No complication such as vascular perforation, rupture, air embolism, thromboembolism, wound infection, or sepsis happened after operation. Arterial crisis occurred again in 3 cases at 1.5-13.5 hours after limb replantation and treated by arterial exploration, 1 case was treated successfully; 2 cases had arterial occlusion and partial necrosis of limb, and got amputation treatment at last. The rest 24 cases survived with the incision healing by first stage. In the 24 cases, 1 case suffered from acute myonephropathic metabolic syndrome and corrected after hemodialysis; 1 case suffered from acute liver functional damage and corrected by comprehensive treatment of internal medicine. The 24 patients were followed up 7-38 months (mean, 11 months). At last follow-up, blood supply of the limb was good with normal skin temperature and improved sense of feeling, activity, and swelling. According to Chinese Medical Association of hand surgery to the upper extremity function assessment standard, the results were

  3. Removal of large hydatid cysts with balloon-assisted modification of Dowling's method: technical report.

    PubMed

    Ulutas, Murat; Cinar, Kadir; Secer, Mehmet

    2015-07-01

    Delivery of hydatid cysts, especially large ones, without rupture is very important and there is still no 100% successful method. After the hydatid cyst was reached, starting near the surface working around the cyst toward the base, a Foley probe was advanced and, in the region of desired dissection, the balloon of the Foley probe was inflated, and adhesion bands were freed to allow dissection. We believe our balloon-aided dissection technique is a method that increases the chances of delivering hydatid cysts, with no calcification and secondary infection, without rupture.

  4. Perineal Pseudoaneurysm from Traumatic Foley Removal Leads to Recurrent Life-Threatening Hematuria.

    PubMed

    Liang, Lorraine Min-Shan; Xue, Jingbing; Erturk, Erdal

    2015-01-01

    Hematuria resulting from urethral traumatic catheter insertion and removal is often encountered. Usually, hematuria resolves with conservative measures. We report a case of traumatic Foley removal leading to intermittent life-threatening hematuria resulting in blood loss anemia requiring multiple transfusions and multiple episodes of hypotension requiring pressors. A pelvic angiogram revealed a pseudoaneurysm of the left pudendal artery, which was treated with microcoil embolization leading to resolution of bleeding.

  5. Evaluation of a Dedicated Balloon Catheter for Infrapopliteal Difficult Calcified Lesions in Diabetic Patients With Critical Limb Ischemia

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lupattelli, Tommaso, E-mail: tommasolupattelli@hotmail.com

    2011-02-15

    The purpose of this study was to assess the technical performance and immediate procedural outcome of a new balloon catheter in the treatment of calcified lesions in infrapopliteal arterial disease. Sixty-one patients (81 vessels) with infrapopliteal arterial disease were evaluated. Seventy-four of the 81 treated vessels had total occlusions. The ReeKross 18 peripheral transluminal angioplasty catheter (ClearStream, Wexford, Ireland) is an 0.018-inch guidewire system with 4F sheath compatibility and a rigid shaft intended for enhanced pushability. Only technical procedural outcomes were recorded. In 37 of 61 patients (50 infrapopliteal severely stenosed or occluded vessels), an attempt with a standard balloonmore » was made before the ReeKross 18 was used. In 24 patients, the ReeKross 18 was used as the primary catheter in 23 cases involving crural arteries and in 8 cases involving the foot. The ReeKross 18 crossed the lesion in 55 of 59 (93.2%) patients and 72 of 77 (94.5%) vessels, respectively. Postdilatation results for the 51 patients (64 target lesions) in whom ReeKross 18 balloon dilation was achieved showed <30% residual stenosis in all but 4 patients (5 lesions). Of the patients treated with the ReeKross 18 as the primary catheter, the technical success rate (no adjunctive treatment/stent) was obtained in 20 of 24 (83.3%) patients (27 of 31 [87.1%] target lesions). In the treatment of difficult calcified lesions, the choice of a high-pushability angioplasty catheter, such as the ReeKross 18, warrants consideration.« less

  6. Double Guiding Catheters for Complex Percutaneous Coronary Intervention

    PubMed Central

    Chou, Shing-Hsien; Lin, Chia-Pin; Lin, Yen-Chen; Kuo, Chi-Tai; Lin, Ming-Shyan; Chang, Chi-Jen

    2012-01-01

    A large-lumen guiding catheter is often used for complex percutaneous coronary intervention—particularly when a final kissing-balloon or 2-stent technique is required. However, catheter insertion is sometimes restricted by diseased vascular access sites or a tortuous vascular route. We report 2 cases in which a unique double guiding catheter technique was used to create a lumen of sufficient size for complex percutaneous coronary intervention. In each patient, two 6F guiding catheters were used concurrently to engage the ostium of 1 target vessel. In 1 patient, these catheters were used for the delivery of 2 balloons to complete kissing-balloon dilation after single-stent placement. In the other patient, the catheters were used to deliver 2 stents sequentially to their respective target lesions. The stents were then deployed simultaneously as kissing stents, followed by high-pressure kissing-balloon postdilation. PMID:22412243

  7. Arterioureteral Fistula: Treatment of a Hemorrhagic Shock with Massive Hematuria by Placing a Balloon Catheter.

    PubMed

    Merzeau, Nicolas; Riquet, Hervé; Nicolacopoulos, Ioannis; Alame, Abbas; Larré, Stéphane

    2017-01-01

    Arterioureteral fistulas (AUF) are serious diseases with increasing incidence. This case report relates the management of AUF in a patient with a history of abdominal oncological surgery, pelvic radiotherapy, and a double J stent in place. The fistula was discovered during a hemorrhagic shock with massive hematuria. The bleeding was controlled by a balloon catheter which led to endovascular treatment consisting of a covered stent.

  8. Arterioureteral Fistula: Treatment of a Hemorrhagic Shock with Massive Hematuria by Placing a Balloon Catheter

    PubMed Central

    Riquet, Hervé; Nicolacopoulos, Ioannis; Alame, Abbas

    2017-01-01

    Arterioureteral fistulas (AUF) are serious diseases with increasing incidence. This case report relates the management of AUF in a patient with a history of abdominal oncological surgery, pelvic radiotherapy, and a double J stent in place. The fistula was discovered during a hemorrhagic shock with massive hematuria. The bleeding was controlled by a balloon catheter which led to endovascular treatment consisting of a covered stent. PMID:28465857

  9. Perineal Pseudoaneurysm from Traumatic Foley Removal Leads to Recurrent Life-Threatening Hematuria

    PubMed Central

    Xue, Jingbing; Erturk, Erdal

    2015-01-01

    Abstract Hematuria resulting from urethral traumatic catheter insertion and removal is often encountered. Usually, hematuria resolves with conservative measures. We report a case of traumatic Foley removal leading to intermittent life-threatening hematuria resulting in blood loss anemia requiring multiple transfusions and multiple episodes of hypotension requiring pressors. A pelvic angiogram revealed a pseudoaneurysm of the left pudendal artery, which was treated with microcoil embolization leading to resolution of bleeding. PMID:27579388

  10. Paclitaxel-Coated Balloon in Infrapopliteal Arteries: 12-Month Results From the BIOLUX P-II Randomized Trial (BIOTRONIK'S-First in Man study of the Passeo-18 LUX drug releasing PTA Balloon Catheter vs. the uncoated Passeo-18 PTA balloon catheter in subjects requiring revascularization of infrapopliteal arteries).

    PubMed

    Zeller, Thomas; Beschorner, Ulrich; Pilger, Ernst; Bosiers, Marc; Deloose, Koen; Peeters, Patrick; Scheinert, Dierk; Schulte, Karl-Ludwig; Rastan, Aljoscha; Brodmann, Marianne

    2015-10-01

    The aim of BIOLUX P-II (BIOTRONIK'S-First in Man study of the Passeo-18 LUX drug releasing PTA Balloon Catheter vs. the uncoated Passeo-18 PTA balloon catheter in subjects requiring revascularization of infrapopliteal arteries) trial was to compare the safety and efficacy of a novel paclitaxel-coated drug-eluting balloon (DEB) versus an uncoated balloon (percutaneous transluminal angioplasty [PTA]) in de novo or native restenotic lesions of the infrapopliteal arteries in patients with claudication and critical limb ischemia. DEB have shown promising results in femoropopliteal lesions, but data for infrapopliteal lesions are scarce. In this prospective, multicenter, randomized first-in-man study, 72 patients were randomized 1:1 to either a Passeo-18 Lux DEB (Biotronik AG, Buelach, Switzerland) (n = 36) or Passeo-18 PTA (n = 36). Follow-up assessments were scheduled at 1, 6, and 12 months, with angiographic assessment at 6 months. Adverse events were adjudicated by an independent clinical events committee, and angiographic parameters were assessed by an independent core laboratory. The primary safety endpoint (a composite of all-cause mortality, target extremity major amputation, target lesion thrombosis, and target vessel revascularization at 30 days) was 0% in the DEB group versus 8.3% in the PTA group (p = 0.239). The primary performance endpoint (patency loss at 6 months) was 17.1% in the DEB group versus 26.1% in the PTA group (p = 0.298), and major amputations of the target extremity occurred in 3.3% versus 5.6% of the patients at 12 months, respectively. The Passeo-18 Lux DEB has been proven to be safe and effective in infrapopliteal lesions with comparable outcomes to PTA. Copyright © 2015 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  11. Use of Flexible Cystoscopy to Insert a Foley Catheter over a Guide Wire in Spinal Cord Injury Patients: Special Precautions to be Observed.

    PubMed

    Vaidyanathan, Subramanian; Soni, Bakul; Singh, Gurpreet; Hughes, Peter; Oo, Tun

    2011-01-01

    When urethral catheterisation is difficult or impossible in spinal cord injury patients, flexible cystoscopy and urethral catheterisation over a guide wire can be performed on the bedside, thus obviating the need for emergency suprapubic cystostomy. Spinal cord injury patients, who undergo flexible cystoscopy and urethral catheterisation over a guide wire, may develop potentially serious complications. (1) Persons with lesion above T-6 are susceptible to develop autonomic dysreflexia during cystoscopy and urethral catheterisation over a guide wire; nifedipine 5-10 milligrams may be administered sublingually just prior to the procedure to prevent autonomic dysreflexia. (2) Spinal cord injury patients are at increased risk for getting urine infections as compared to able-bodied individuals. Therefore, antibiotics should be given to patients who get haematuria or urethral bleeding following urethral catheterisation over a guide wire. (3) Some spinal cord injury patients may have a small capacity bladder; in these patients, the guide wire, which is introduced into the urinary bladder, may fold upon itself with the tip of guide wire entering the urethra. If this complication is not recognised and a catheter is inserted over the guide wire, the Foley catheter will then be misplaced in urethra despite using cystoscopy and guide wire.

  12. Use of Flexible Cystoscopy to Insert a Foley Catheter over a Guide Wire in Spinal Cord Injury Patients: Special Precautions to be Observed

    PubMed Central

    Vaidyanathan, Subramanian; Soni, Bakul; Singh, Gurpreet; Hughes, Peter; Oo, Tun

    2011-01-01

    When urethral catheterisation is difficult or impossible in spinal cord injury patients, flexible cystoscopy and urethral catheterisation over a guide wire can be performed on the bedside, thus obviating the need for emergency suprapubic cystostomy. Spinal cord injury patients, who undergo flexible cystoscopy and urethral catheterisation over a guide wire, may develop potentially serious complications. (1) Persons with lesion above T-6 are susceptible to develop autonomic dysreflexia during cystoscopy and urethral catheterisation over a guide wire; nifedipine 5–10 milligrams may be administered sublingually just prior to the procedure to prevent autonomic dysreflexia. (2) Spinal cord injury patients are at increased risk for getting urine infections as compared to able-bodied individuals. Therefore, antibiotics should be given to patients who get haematuria or urethral bleeding following urethral catheterisation over a guide wire. (3) Some spinal cord injury patients may have a small capacity bladder; in these patients, the guide wire, which is introduced into the urinary bladder, may fold upon itself with the tip of guide wire entering the urethra. If this complication is not recognised and a catheter is inserted over the guide wire, the Foley catheter will then be misplaced in urethra despite using cystoscopy and guide wire. PMID:22110492

  13. Balloon-augmented Onyx embolization of cerebral arteriovenous malformations using a dual-lumen balloon: a multicenter experience.

    PubMed

    Spiotta, Alejandro M; James, Robert F; Lowe, Stephen R; Vargas, Jan; Turk, Aquilla S; Chaudry, M Imran; Bhalla, Tarun; Janjua, Rashid M; Delaney, John J; Quintero-Wolfe, Stacey; Turner, Raymond D

    2015-10-01

    Conventional Onyx embolization of cerebral arteriovenous malformations (AVMs) requires lengthy procedure and fluoroscopy times to form an adequate 'proximal plug' which allows forward nidal penetration while preventing reflux and non-targeted embolization. We review our experience with balloon-augmented Onyx embolization of cerebral AVMs using a dual-lumen balloon catheter technique designed to minimize these challenges. Retrospectively acquired data for all balloon-augmented cerebral AVM embolizations performed between 2011 and 2014 were obtained from four tertiary care centers. For each procedure, at least one Scepter C balloon catheter was advanced into the AVM arterial pedicle of interest and Onyx embolization was performed through the inner lumen after balloon inflation via the outer lumen. Twenty patients underwent embolization with the balloon-augmented technique over 24 discreet treatment episodes. There were 37 total arterial pedicles embolized with the balloon-augmented technique, a mean of 1.9 per patient (range 1-5). The treated AVMs were heterogeneous in their location and size (mean 3.3±1.6 cm). Mean fluoroscopy time for each procedure was 48±26 min (28 min per embolized pedicle). Two Scepter C balloon catheter-related complications (8.3% of embolization sessions, 5.4% of pedicles embolized) were observed: an intraprocedural rupture of a feeding pedicle and fracture and retention of a catheter fragment. This multicenter experience represents the largest reported series of balloon-augmented Onyx embolization of cerebral AVMs. The technique appears safe and effective in the treatment of AVMs, allowing more efficient and controlled injection of Onyx with a decreased risk of reflux and decreased fluoroscopy times. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  14. Monorail Piccolino catheter: a new rapid exchange/ultralow profile coronary angioplasty system.

    PubMed

    Mooney, M R; Douglas, J S; Mooney, J F; Madison, J D; Brandenburg, R O; Fernald, R; Van Tassel, R A

    1990-06-01

    The Monorail Piccolino coronary angioplasty balloon catheter (MBC) was evaluated on 118 patients at two centers. Technical success was achieved in 110 patients (93%). Time for catheter exchange and total fluoroscopy time were significantly lower for the Monorail catheter than with standard equipment (exchange time 97 vs. 170 seconds P less than .05 and fluoroscopy time 17 vs. 88 seconds P less than .001). The advantages of rapid exchange and the ability of utilize 2 Monorail balloon catheters through one 9F guiding catheter for simultaneous inflations allowed for maximal flexibility in treating patients with bifurcation lesions. The double wire approach utilizing one Monorail balloon catheter with a 7F guiding catheter was also technically successful. The Monorail Piccolino balloon catheter has unique features that allow for greater ease of operator use, rapid catheter exchange, and optimal angiographic visualization. It is felt that this catheter design provides distinct advantages over standard angioplasty equipment.

  15. How to perform combined cutting balloon and high pressure balloon valvuloplasty for dogs with subaortic stenosis.

    PubMed

    Kleman, Mandi E; Estrada, Amara H; Maisenbacher, Herbert W; Prošek, Robert; Pogue, Brandon; Shih, Andre; Paolillo, Joseph A

    2012-01-01

    Subvalvular aortic stenosis (SAS) is one of the most common congenital cardiac malformations in dogs. Unfortunately, the long term success rate and survival data following either open heart surgery or catheter based intervention has been disappointing in dogs with severe subaortic stenosis. Medical therapy is currently the only standard recommended treatment option. A cutting balloon dilation catheter has been used successfully for resistant coronary artery and peripheral pulmonary arterial stenoses in humans. This catheter is unique in that it has the ability to cut, or score, the stenotic region prior to balloon dilatation of the stenosis. The use of cutting balloon valvuloplasty combined with high pressure valvuloplasty for dogs with severe subaortic stenosis has recently been reported to be a safe and feasible alternative therapeutic option. The following report describes this technique, outlines the materials required, and provides some 'tips' for successful percutaneous subaortic balloon valvuloplasty. Copyright © 2012 Elsevier B.V. All rights reserved.

  16. Fracture, inflation and floatation embolisation of PTCA balloon.

    PubMed

    O'Neill, Louisa; Sowbhaga, Vinay; Owens, Patrick

    2015-01-09

    This case outlines an unusual complication of coronary intervention, the likely mechanisms leading to this and possible retrieval options. It is the first case to the best of our knowledge reporting this complication. A 78-year-old Caucasian man underwent coronary stenting. During the procedure kinking and subsequent fracture of a non-compliant percutaneous transluminal coronary angioplasty (PTCA) balloon occurred. Injection of contrast down the guide to opacify the coronary arteries resulted in 'inflation' of the balloon with air, and embolisation of the inflated balloon into the proximal left anterior descending artery. The embolised balloon was retrieved by removal of the guide catheter and wire as a unit. The patient had a good angiographic outcome. This case highlights risks associated with usage of kinked balloons catheters, and describes for the first time to our knowledge, the inflation of a PTCA balloon with air from its shaft within the catheter, causing 'floatation' embolisation into the coronary artery. 2015 BMJ Publishing Group Ltd.

  17. Fracture, inflation and floatation embolisation of PTCA balloon

    PubMed Central

    O'Neill, Louisa; Sowbhaga, Vinay; Owens, Patrick

    2015-01-01

    This case outlines an unusual complication of coronary intervention, the likely mechanisms leading to this and possible retrieval options. It is the first case to the best of our knowledge reporting this complication. A 78-year-old Caucasian man underwent coronary stenting. During the procedure kinking and subsequent fracture of a non-compliant percutaneous transluminal coronary angioplasty (PTCA) balloon occurred. Injection of contrast down the guide to opacify the coronary arteries resulted in ‘inflation’ of the balloon with air, and embolisation of the inflated balloon into the proximal left anterior descending artery. The embolised balloon was retrieved by removal of the guide catheter and wire as a unit. The patient had a good angiographic outcome. This case highlights risks associated with usage of kinked balloons catheters, and describes for the first time to our knowledge, the inflation of a PTCA balloon with air from its shaft within the catheter, causing ‘floatation’ embolisation into the coronary artery. PMID:25576524

  18. Percutaneous intraportal application of adipose tissue-derived mesenchymal stem cells using a balloon occlusion catheter in a porcine model of liver fibrosis.

    PubMed

    Avritscher, Rony; Abdelsalam, Mohamed E; Javadi, Sanaz; Ensor, Joe; Wallace, Michael J; Alt, Eckhard; Madoff, David C; Vykoukal, Jody V

    2013-12-01

    To investigate the safety and effectiveness of a novel endovascular approach for therapeutic cell delivery using a balloon occlusion catheter in a large animal model of liver fibrosis. Transcatheter arterial embolization with ethiodized oil (Ethiodol) and ethanol was used to induce liver damage in 11 pigs. Mesenchymal stem cells (MSCs) were harvested from adipose tissue and engineered to express green fluorescent protein (GFP). A balloon occlusion catheter was positioned in the bilateral first-order portal vein branches 2 weeks after embolization to allow intraportal application of MSCs in six experimental animals. MSCs were allowed to dwell for 10 minutes using prolonged balloon inflation. Five control animals received a sham injection of normal saline in a similar fashion. Hepatic venous pressure gradient (HVPG) was measured immediately before necropsy. Specimens from all accessible lobes were obtained with ultrasound-guided percutaneous 18-gauge biopsy 2 hours after cell application. All animals were euthanized within 4 weeks. Fluorescent microscopy was used to assess the presence and distribution of cells. Liver injury and fibrosis were successfully induced in all animals. MSCs (6-10 × 10(7)) were successfully delivered into the portal vein in the six experimental animals. Cell application was not associated with vascular complications. HVPG showed no instances of portal hypertension. GFP-expressing MSCs were visualized in biopsy specimens and were distributed primarily within the sinusoidal spaces; however, 4 weeks after implantation, MSCs could not be identified in histologic specimens. A percutaneous endovascular approach for cell delivery using a balloon occlusion catheter proved safe for intraportal MSC application in a large animal model of liver fibrosis. © 2013 SIR Published by SIR All rights reserved.

  19. 21 CFR 876.5130 - Urological catheter and accessories.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... device that is inserted through the urethra and used to pass fluids to or from the urinary tract. This..., coude catheters, balloon retention type catheters, straight catheters, upper urinary tract catheters...

  20. Clinical Evaluation of a Safety-device to Prevent Urinary Catheter Inflation Related Injuries.

    PubMed

    Davis, Niall F; Cunnane, Eoghan M; Mooney, Rory O'C; Forde, James C; Walsh, Michael T

    2018-05-01

    To evaluate the feasibility of a novel "safety-valve" device for preventing catheter related urethral trauma during urethral catheterization (UC). To assess the opinions of clinicians on the performance of the safety-valve device. A validated prototype "safety-valve" device for preventing catheter balloon inflation related urethral injuries was prospectively piloted in male patients requiring UC in a tertiary referral teaching hospital (n = 100). The device allows fluid in the catheter system to decant through an activated safety threshold pressure valve if the catheter anchoring balloon is misplaced. Users evaluated the "safety-valve" with an anonymous questionnaire. The primary outcome measurement was prevention of anchoring balloon inflation in the urethra. Secondary outcome measurement was successful inflation of urinary catheter anchoring balloon in the bladder. Patient age was 76 ± 12 years and American Society of Anaesthesiologists grade was 3 ± 1.4. The "safety-valve" was utilized by 34 clinicians and activated in 7% (n = 7/100) patients during attempted UC, indicating that the catheter anchoring balloon was incorrectly positioned in the patient's urethra. In these 7 cases, the catheter was successfully manipulated into the urinary bladder and inflated. 31 of 34 (91%) clinicians completed the questionnaire. Ten percent (n = 3/31) of respondents had previously inflated a urinary catheter anchoring balloon in the urethra and 100% (n = 31) felt that a safety mechanism for preventing balloon inflation in the urethra should be compulsory for all UCs. The safety-valve device piloted in this clinical study offers an effective solution for preventing catheter balloon inflation related urethral injuries. Copyright © 2018 Elsevier Inc. All rights reserved.

  1. Percutaneous balloon pulmonary valvuloplasty (PBPV) of extreme pulmonary valve stenosis by the use of Accura balloon.

    PubMed

    Sinha, Santosh Kumar; Mishra, Vikas; Razi, Mahmadula; Jha, Mukesh Jitendra

    2017-10-04

    Transcatheter therapy of valvular pulmonary stenosis is one of first catheter interventions facilitating its application in field of structural heart disease and now treatment of choice for significant pulmonary stenosis. Myriads of balloon catheter have been used for this purpose starting from Diamond (Boston Scientific,Natick, MA USA), Marshal (Medi-Tech,Watertown MAUSA), Innoue balloon, Tyshak I and currently Tyshak II. Diameter and length of balloon depend on size of annulus and age group, respectively. Problem with shorter balloon is difficulty in keeping it across the annulus while inflation as it tends to slip distally whereas with longer balloon, potential of tricuspid leak or conduction block as it may impinge on adjacent structures. Potential advantage of Accura balloon over Tyshak balloon lies in its peculiar shape while inflation and variable diameter, making stepwise dilatation possible. Here, we report a case of successful balloon pulmonary valvuloplasty using Accura balloon (Vascular Concept, UK) with little modification of conventional technique. © BMJ Publishing Group Ltd (unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  2. [Coronary angioplasty with the Monorail system via 6 French diagnostic catheters].

    PubMed

    Villavicencio, R; González, H; López, J; Zavala, E; Ban Hayashi, E B; Gaspar, J; Gil, M; Martínez Ríos, M A

    1994-01-01

    We studied the use of "Monorail" system with Express (Scimed) balloon catheters for coronary angioplasty through 6 French (F) "high-flow" diagnostic catheters (Novoste, USCI). Prospectively, from July 1992 to January 1993, angioplasty of 31 lesions in 24 patients was attempted (1.3 lesions/procedure). Twenty procedures were of a single lesion and four were multi-vessel angioplasty. Fourteen lesions were in the left anterior descending or in its branches, 10 in the left circumflex or in its branches, 6 in the right coronary artery, and one in the distal anastomosis of an internal mammary artery graft. Thirteen lesions (42%) were type A, 17 (55%) type B and one (3%) type C. Balloon sizes varied between 2.0 and 3.5 mm. Twenty-nine lesions could be successfully dilated (93.5%); two cases were unsuccessful due to an acute occlusion in one and residual stenosis of more than 50% in the other. For only one case, another balloon catheter different from the "Monorail" system was necessary to complete a multi-vessel angioplasty. Coronary visualization and manipulation of the balloon through the tip of the diagnostic catheter were satisfactory in all cases, except with the 3.5 mm balloon catheter. Coronary angioplasty with "Monorail" system balloon catheters through 6 F "high-flow" diagnostic catheters is feasible and provides a high success rate in simple and moderately complex selected lesions, including multivessel angioplasty with advantages of smaller artery punction and the feasibility of performing coronary angioplasty with the same catheter used for diagnostic angiography.

  3. The Crataegus extract WS 1442 inhibits balloon catheter-induced intimal hyperplasia in the rat carotid artery by directly influencing PDGFR-beta.

    PubMed

    Fürst, Robert; Zirrgiebel, Ute; Totzke, Frank; Zahler, Stefan; Vollmar, Angelika M; Koch, Egon

    2010-08-01

    Effective systemic drugs against restenosis upon percutaneous transluminal coronary angioplasty (PTCA) are largely lacking. Polyphenols have been suggested to ameliorate post-angioplasty restenosis. Hawthorn (Crataegus spp.) extracts, which are among the most frequently used herbal medicinal products against mild forms of congestive heart failure, contain polyphenols, but have not been investigated in this context. We aimed to assess the potential of the hawthorn extract WS 1442 to prevent balloon catheter-induced intimal hyperplasia and to elucidate the underlying mechanisms. We analyzed the effects of WS 1442 on serum-induced vascular smooth muscle cell (VSMC) and endothelial cell (EC) growth and migration, growth factor-induced proliferation, growth factor receptor activity, and neointima formation in the rat carotid artery model. WS 1442 (100 microg/ml) decreased VSMC migration by 38% and proliferation by 44%, whereas EC migration and proliferation were unaltered. The extract inhibited VSMC DNA synthesis induced by platelet-derived growth factor (PDGF) (IC(50): 47 microg/ml), but not that of basic fibroblast growth factor (bFGF) and epidermal growth factor (EGF). Along this line, WS 1442 blocked recombinant human PDGF receptor (PDGFR)-beta kinase activity (IC(50): 1.4 microg/ml) and decreased PDGFR-beta activation and extracellular signal-regulated kinase (ERK) activation in VSMCs. In rats, orally administered WS 1442 significantly reduced neointima formation after balloon catheter dilatation of the carotid artery. WS 1442 inhibits migration and proliferation of VSMCs, but not of ECs, and reduces balloon catheter-evoked neointima formation probably through inhibition of PDGFR-beta. Thus, the present study suggests a novel adjunct pharmacological strategy to prevent angioplasty-related restenosis. Copyright 2010 Elsevier Ireland Ltd. All rights reserved.

  4. The quest for durable lesions in catheter ablation of atrial fibrillation - technological advances in radiofrequency catheters and balloon devices.

    PubMed

    Maurer, Tilman; Kuck, Karl-Heinz

    2017-08-01

    Atrial fibrillation is the most common cardiac arrhythmia and represents a growing clinical, social and economic challenge. Catheter ablation for symptomatic atrial fibrillation has evolved from an experimental procedure into a widespread therapy and offers a safe and effective treatment option. A prerequisite for durable PVI are transmural and contiguous circumferential lesions around the pulmonary veins. However, electrical reconnection of initially isolated pulmonary veins remains a primary concern and is a dominant factor for arrhythmia recurrence during long-term follow up. Areas covered: This article discusses the physiology of lesion formation using radiofrequency-, cryo- or laser- energy for pulmonary vein isolation and provides a detailed review of recent technological advancements in the field of radiofrequency catheters and balloon devices. Finally, future directions and upcoming developments for the interventional treatment of atrial fibrillation are discussed. Expert commentary: Durable conduction block across deployed myocardial lesions is mandatory not only for PVI but for any other cardiac ablation strategy as well. A major improvement urgently expected is the intraprocedural real-time distinction of durable lesions from interposed gaps with only transiently impaired electrical conduction. Furthermore, a simplification of ablation tools used for PVI is required to reduce the high technical complexity of the procedure.

  5. Contura Multi-Lumen Balloon breast brachytherapy catheter: comparative dosimetric findings of a phase 4 trial.

    PubMed

    Arthur, Douglas W; Vicini, Frank A; Todor, Dorin A; Julian, Thomas B; Cuttino, Laurie W; Mukhopadhyay, Nitai D

    2013-06-01

    Final dosimetric findings of a completed, multi-institutional phase 4 registry trial using the Contura Multi-Lumen Balloon (MLB) breast brachytherapy catheter to deliver accelerated partial breast irradiation (APBI) in patients with early-stage breast cancer are presented. Three dosimetric plans with identical target coverage were generated for each patient for comparison: multilumen multidwell (MLMD); central-lumen multidwell (CLMD); and central-lumen single-dwell (CLSD) loading of the Contura catheter. For this study, a successful treatment plan achieved ideal dosimetric goals and included the following: ≥ 95% of the prescribed dose (PD) covering ≥ 95% of the target volume (TV); maximum skin dose ≤ 125% of the PD; maximum rib dose ≤ 145% of the PD; and V150 ≤50 cc and V200 ≤ 10 cc. Between January 2008 and February 2011, 23 institutions participated. A total of 318 patients were available for dosimetric review. Using the Contura MLB, all dosimetric criteria were met in 78.93% of cases planned with MLMD versus 55.38% with the CLMD versus 37.66% with the CLSD (P ≤.0001). Evaluating all patients with the full range of skin to balloon distance represented, median maximum skin dose was reduced by 12% and median maximum rib dose by 13.9% when using MLMD-based dosimetric plans compared to CLSD. The dosimetric benefit of MLMD was further demonstrated in the subgroup of patients where skin thickness was <5 mm, where MLMD use allowed a 38% reduction in median maximum skin dose over CLSD. For patients with rib distance <5 mm, the median maximum rib dose reduction was 27%. Use of the Contura MLB catheter produced statistically significant improvements in dosimetric capabilities between CLSD and CLMD treatments. This device approach demonstrates the ability not only to overcome the barriers of limited skin thickness and close rib proximity, but to consistently achieve a higher standard of dosimetric planning goals. Copyright © 2013 Elsevier Inc. All rights

  6. Contura Multi-Lumen Balloon Breast Brachytherapy Catheter: Comparative Dosimetric Findings of a Phase 4 Trial

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Arthur, Douglas W., E-mail: darthur@mcvh-vcu.edu; Vicini, Frank A.; Todor, Dorin A.

    2013-06-01

    Purpose: Final dosimetric findings of a completed, multi-institutional phase 4 registry trial using the Contura Multi-Lumen Balloon (MLB) breast brachytherapy catheter to deliver accelerated partial breast irradiation (APBI) in patients with early-stage breast cancer are presented. Methods and Materials: Three dosimetric plans with identical target coverage were generated for each patient for comparison: multilumen multidwell (MLMD); central-lumen multidwell (CLMD); and central-lumen single-dwell (CLSD) loading of the Contura catheter. For this study, a successful treatment plan achieved ideal dosimetric goals and included the following: ≥95% of the prescribed dose (PD) covering ≥95% of the target volume (TV); maximum skin dose ≤125%more » of the PD; maximum rib dose ≤145% of the PD; and V150 ≤50 cc and V200 ≤10 cc. Results: Between January 2008 and February 2011, 23 institutions participated. A total of 318 patients were available for dosimetric review. Using the Contura MLB, all dosimetric criteria were met in 78.93% of cases planned with MLMD versus 55.38% with the CLMD versus 37.66% with the CLSD (P≤.0001). Evaluating all patients with the full range of skin to balloon distance represented, median maximum skin dose was reduced by 12% and median maximum rib dose by 13.9% when using MLMD-based dosimetric plans compared to CLSD. The dosimetric benefit of MLMD was further demonstrated in the subgroup of patients where skin thickness was <5 mm, where MLMD use allowed a 38% reduction in median maximum skin dose over CLSD. For patients with rib distance <5 mm, the median maximum rib dose reduction was 27%. Conclusions: Use of the Contura MLB catheter produced statistically significant improvements in dosimetric capabilities between CLSD and CLMD treatments. This device approach demonstrates the ability not only to overcome the barriers of limited skin thickness and close rib proximity, but to consistently achieve a higher standard of dosimetric

  7. 21 CFR 870.5150 - Embolectomy catheter.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    .... (a) Identification. An embolectomy catheter is a balloon-tipped catheter that is used to remove thromboemboli, i.e., blood clots which have migrated in blood vessels from one site in the vascular tree to...

  8. Determining the best catheter for sonohysterography.

    PubMed

    Dessole, S; Farina, M; Capobianco, G; Nardelli, G B; Ambrosini, G; Meloni, G B

    2001-09-01

    To compare the characteristics of six different catheters for performing sonohysterography (SHG) to identify those that offer the best compromise between reliability, tolerability, and cost. Prospective study. University hospital. Six hundred ten women undergoing SHG. We performed SHG with six different types of catheters: Foleycath (Wembley Rubber Products, Sepang, Malaysia), Hysca Hysterosalpingography Catheter (GTA International Medical Devices S.A., La Caleta D.N., Dominican Republic), H/S Catheter Set (Ackrad Laboratories, Cranford, NJ), PBN Balloon Hystero-Salpingography Catheter (PBN Medicals, Stenloese, Denmark), ZUI-2.0 Catheter (Zinnanti Uterine Injection; BEI Medical System International, Gembloux, Belgium), and Goldstein Catheter (Cook, Spencer, IN). We assessed the reliability, the physician's ease of use, the time requested for the insertion of the catheter, the volume of contrast medium used, the tolerability for the patients, and the cost of the catheters. In 568 (93%) correctly performed procedures, no statistically significant differences were found among the catheters. The Foleycath was the most difficult for the physician to use and required significantly more time to position correctly. The Goldstein catheter was the best tolerated by the patients. The Foleycath was the cheapest whereas the PBN Balloon was the most expensive. The choice of the catheter must be targeted to achieving a good balance between tolerability for the patients, efficacy, cost, and the personal preference of the operator.

  9. Transthoracic ultrasound guided balloon dilation of cor triatriatum dexter in 2 Rottweiler puppies.

    PubMed

    Birettoni, F; Caivano, D; Bufalari, A; Giorgi, M E; Miglio, A; Paradies, P; Porciello, F

    2016-12-01

    Balloon dilation was performed in two Rottweiler puppies with cor triatriatum dexter and clinical signs of ascites using transthoracic echocardiographic guidance. The dogs were positioned on a standard echocardiography table in right lateral recumbency, and guide wires and balloon catheters were imaged by echocardiographic views optimized to allow visualization of the defect. The procedures were performed successfully without complications and clinical signs were resolved completely in both cases. Guide wires and balloon catheters appeared hyperechoic on transthoracic echocardiography image and could be clearly monitored and guided in real-time. These two cases demonstrate that it is possible to perform balloon catheter dilation of cor triatriatum dexter under transthoracic guidance alone. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. Hygroscopic dilators vs balloon catheter ripening of the cervix for induction of labor in nulliparous women at term: Retrospective study

    PubMed Central

    Shindo, Ryosuke; Yonemoto, Naohiro; Yamamoto, Yuriko; Kasai, Junko; Kasai, Michi; Miyagi, Etsuko

    2017-01-01

    Objective To compare the efficacy and safety of hygroscopic dilators and balloon catheters for ripening of the cervix in induction of labor. Study design This retrospective, observational study used data from the Successive Pregnancy Birth Registry System of the Japan Society of Obstetrics and Gynecology from 2012 to 2014. Nulliparous women in whom labor was induced by mechanical methods of cervical ripening at term were enrolled. The eligible women were divided into dilator, balloon <40 mL, balloon ≧40 mL, and overlapping groups. Results The groups included 4645, 4100, 6615, and 1992 women, respectively. In the overlapping group, which included the women in whom delivery was most difficult, the vaginal delivery rate was lower and the intrauterine infection and neonatal mortality rates were higher than those in the dilator group. No difference in the vaginal delivery rate was observed among the dilator, balloon <40 mL, and balloon ≧40 mL groups (74.6%, 72.3%, and 73.8%, respectively; p>0.05). The vaginal instrumental delivery rate was higher in the two-balloon groups than in the dilator group. The volume of intrapartum hemorrhage was lowest in the dilator group. No significant difference in the frequencies of uterine rupture and intrauterine infection were observed among the dilator and two-balloon groups. With regard to neonatal outcomes, the frequency of a low Apgar score was statistically significantly lower in the dilator group than in the two-balloon groups. Moreover, the frequency of neonatal death tended to be lower in the dilator group than in the two-balloon groups. Conclusion With regard to cervical ripening for labor induction in nulliparous women at term, the vaginal delivery rate on using a dilator and on using a balloon seems to be equivalent. Concerning maternal complications and neonatal outcomes, cervical ripening with hygroscopic dilators in labor induction might be safer. PMID:29272277

  11. Acute urinary retention: which catheter?

    PubMed Central

    Allardice, J. T.; Standfield, N. J.; Wyatt, A. P.

    1988-01-01

    There is no scientific data on which is the best method and catheter to use in acute urinary retention in males. We therefore compared the efficiency of a size 12 G latex rubber balloon catheter with a similar calibre but more expensive catheter made of polyvinyl-chloride (PVC). A total of 50 patients was studied and a 100% successful catheterisation rate was recorded at first attempt with both catheters, with no significant complications. The importance of the correct management of acute urinary retention, especially adequate analgesia, is stressed and it is concluded that either catheter is satisfactory. PMID:3207328

  12. You're a What? Foley Artist

    ERIC Educational Resources Information Center

    Vilorio, Dennis

    2011-01-01

    In this article, the author talks about a small occupation of sound reproduction specialists known as foley artists. Foley artists work behind the scenes in filmmaking and television, using props to recreate all the physical sounds that are integrated into a movie or TV show. These sounds need to be recreated because the microphones used on a set…

  13. Endovascular balloon-assisted embolization of intracranial and cervical arteriovenous malformations using dual-lumen coaxial balloon microcatheters and Onyx: initial experience.

    PubMed

    Jagadeesan, Bharathi D; Grigoryan, Mikayel; Hassan, Ameer E; Grande, Andrew W; Tummala, Ramachandra P

    2013-12-01

    Ethylene vinyl alcohol copolymer (Onyx) is widely used for the embolization of arteriovenous malformations (AVMs) of the brain, head, and neck. Balloon-assisted Onyx embolization may provide additional unique advantages in the treatment of AVMs in comparison with traditional catheter-based techniques. To report our initial experience in performing balloon-assisted AVM embolization for brain and neck AVMs with the use of the new Scepter-C and Scepter-XC coaxial dual-lumen balloon microcatheters. Balloon-assisted transarterial embolization was performed in a series of 7 patients with AVMs (4 with brain AVMs, 1 with a dural arteriovenous fistula, and 2 with neck AVMs) by using Onyx delivered through the lumen of Scepter-C or Scepter XC coaxial balloon microcatheters. Following the initial balloon-catheter navigation into a feeding artery and the subsequent inflation of the balloon, the embolization was performed by using Onyx 18, Onyx 34, or both. A total of 12 embolization sessions were performed via 17 arterial feeders in these 7 patients. In 1 patient, there was an arterial perforation from the inflation of the balloon; in all others, the embolization goals were successfully achieved with no adverse events. The balloon microcatheters showed excellent navigability, and there were no problems with retrieval or with the repeated inflation and deflation of the balloons. A proximal Onyx plug, which is crucial in many AVM embolizations, was not necessary with this technique. Additionally, fluoroscopy and procedural times seemed lower with this technique compared with conventional embolization methods.

  14. Intravascular Raman spectroscopic catheter for molecular diagnosis of atherosclerotic coronary disease

    NASA Astrophysics Data System (ADS)

    Komachi, Yuichi; Sato, Hidetoshi; Tashiro, Hideo

    2006-10-01

    An intravascular catheter for Raman spectroscopic detection and analysis of coronary atherosclerotic disease has been developed. The catheter, having an outer diameter of 2 mm, consisted of a side-view-type micro-Raman probe, an imaging fiber bundle, a working channel (injection drain), and a balloon. By inflating the balloon, the probe was brought close to the inner wall of a modeled blood flow system and detected a phantom target buried in the wall. Results obtained demonstrate the possibility of using the spectroscopic catheter for molecular diagnosis of coronary lesions.

  15. Left spermatic vein retrograde sclerosis: comparison between sclerosant agent injection through a diagnostic catheter versus through an occluding balloon catheter.

    PubMed

    Basile, Antonio; Failla, Giovanni; La Vignera, Sandro; Condorelli, Rosita Angela; Calogero, Aldo; Vicari, Enzo; Granata, Antonio; Mundo, Elena; Caltabiano, Giuseppe; Pizzarelli, Marco; Messina, Martina; Scavone, Giovanni; Lanzafame, Franz; Iezzi, Roberto; Tsetis, Dimitrios

    2015-05-01

    The aim of this study was to compare the technical success between left spermatic vein (LSV) scleroembolisation achieved with the injection of sclerosant through a diagnostic catheter and through an occluding balloon (OB), in the treatment of male varicocele. From January 2012 to September 2013, we prospectively enrolled 100 patients with left varicocele and an indication for LSV scleroembolisation related to symptoms or spermiogram anomalies; patients were randomised to two groups (we wrote a list of 100 lines assigned casually with A or B and each patient was consecutively allocated to group A or B on the basis of this list). Patients in group A underwent injection of the sclerosing agent through an angiographic diagnostic catheter (free catheter technique) and patients in group B through an OB catheter (OB technique). In cases of incomplete occlusion of the LSV, the procedure was completed with coils. Total occlusion of the LSV at post-treatment phlebography during a Valsalva manoeuvre before any coil embolisation was considered a technical success. The rate of complications was also evaluated. The Fischer's test was used for statistical analysis. We evaluated a total of 90 patients because five patients for each group were not included in the statistical analysis owing to technical problems or complications. In group A we had a technical success of 75.6 versus 93.4 % in group B, and the difference was statistically significant (P = 0.003); in particular, we had to complete the embolisation with insertion of coils in 11 cases (24.4 %) in group A, and in three cases in group B (6.6 %). In group A, LSV rupture occurred in four cases (8 %) so the procedure was completed by sclerosant injection through the OB located distally to the lesion. These patients were not considered for evaluation. In another case, a high flow shunt towards the inferior vena cava was detected, so the patient underwent OB injection to stop the flow to the shunt, and was not included

  16. Retrograde suction decompression of a large internal carotid aneurysm using a balloon guide catheter combined with a blood-returning circuit and STA-MCA bypass: a technical note.

    PubMed

    Matano, Fumihiro; Mizunari, Takayuki; Kominami, Shushi; Suzuki, Masanori; Fujiki, Yu; Kubota, Asami; Kobayashi, Shiro; Murai, Yasuo; Morita, Akio

    2017-04-01

    It is difficult to treat large internal carotid aneurysms with simple surgical clipping. Here, we present a retrograde suction decompression (RSD) procedure for large internal carotid aneurysms using a balloon guide catheter combined with a blood-returning circuit and a superficial temporal artery to middle cerebral artery (STA-MCA) bypass.All patients underwent an STA-MCA bypass before the temporary occlusion of the internal carotid artery (ICA). A 6-French sheath was inserted into the common carotid artery (CCA), and a 6-French Patrive balloon catheter was placed into the ICA 5 cm past the bifurcation. Aneurysm exposure was obtained; temporary clips were placed on the proximal M1, A1, and posterior communicating (Pcom) segments; and an extension tube was then connected to the balloon catheter. A three-way stopcock was placed, and aspiration was performed through the device to collapse the aneurysm. The aspirated blood was returned to a venous line with an added heparin to prevent anemia after aspiration. During the decompression, the blood flow to the cortical area was supplied through the STA-MCA bypass. After the aneurysm collapse, the surgeon carefully dissected the perforating artery from the aneurysm dome or neck, and permanent clips were then placed on the aneurysm neck. Our procedure has several advantages, such as STA-MCA bypass without external carotid artery occlusion for preventing ischemic complications of the cortical area, anemia may be avoided because of the return of the aspirated blood, and a hybrid operation room is not required to perform this method.

  17. Navigation for fluoroscopy-guided cryo-balloon ablation procedures of atrial fibrillation

    NASA Astrophysics Data System (ADS)

    Bourier, Felix; Brost, Alexander; Kleinoeder, Andreas; Kurzendorfer, Tanja; Koch, Martin; Kiraly, Attila; Schneider, Hans-Juergen; Hornegger, Joachim; Strobel, Norbert; Kurzidim, Klaus

    2012-02-01

    Atrial fibrillation (AFib), the most common arrhythmia, has been identified as a major cause of stroke. The current standard in interventional treatment of AFib is the pulmonary vein isolation (PVI). PVI is guided by fluoroscopy or non-fluoroscopic electro-anatomic mapping systems (EAMS). Either classic point-to-point radio-frequency (RF)- catheter ablation or so-called single-shot-devices like cryo-balloons are used to achieve electrically isolation of the pulmonary veins and the left atrium (LA). Fluoroscopy-based systems render overlay images from pre-operative 3-D data sets which are then merged with fluoroscopic imaging, thereby adding detailed 3-D information to conventional fluoroscopy. EAMS provide tracking and visualization of RF catheters by means of electro-magnetic tracking. Unfortunately, current navigation systems, fluoroscopy-based or EAMS, do not provide tools to localize and visualize single shot devices like cryo-balloon catheters in 3-D. We present a prototype software for fluoroscopy-guided ablation procedures that is capable of superimposing 3-D datasets as well as reconstructing cyro-balloon catheters in 3-D. The 3-D cyro-balloon reconstruction was evaluated on 9 clinical data sets, yielded a reprojected 2-D error of 1.72 mm +/- 1.02 mm.

  18. Minimizing bleeding complications in spinal tumor surgery with preoperative Onyx embolization via dual-lumen balloon catheter.

    PubMed

    Ladner, Travis R; He, Lucy; Lakomkin, Nikita; Davis, Brandon J; Cheng, Joseph S; Devin, Clinton J; Mocco, J

    2016-02-01

    Intraoperative bleeding is a significant risk in surgery for highly vascular spinal tumors, but preoperative embolization can safely decrease intraoperative blood loss in extrinsic spine tumors. Onyx, widely used for cerebrovascular embolization, has been increasingly used as an embolic agent for preoperative spinal tumor embolization. The Scepter catheter, a dual-lumen balloon catheter, may improve tumor parenchymal penetration without the danger and limitations of significant embolic reflux. This may reduce bleeding risk during spinal surgery. Eleven consecutive cases of preoperative Onyx embolization of extrinsic spinal tumors were identified, all of whom had subsequent spinal surgery. Demographic data and clinical variables were collected. Patients were divided into Scepter (n=6) and non-Scepter (n=5) groups. The Mann-Whitney U test was used to compare continuous outcome variables and the Fisher exact test was used to compare categorical variables. Estimated blood loss in the Scepter group was significantly lower than in the non-Scepter group (584±124 vs 2400±738 mL, p=0.004). The volume of intraoperative transfusion was also significantly lower (1.2±0.4 vs 5.8±1.7 units, p=0.004). There was no significant difference in the number of vessels embolized, vials of Onyx used, use of coiling adjunct, contrast load, radiation dose, or fluoroscopy time per pedicle (p>0.05). The addition of the Scepter catheter to preoperative Onyx embolization is safe and feasible. In this small series, the Scepter catheter was associated with a reduction of intraoperative bleeding by 76% and a 79% lower transfusion volume. This was not accompanied by any unwanted increase in vials of Onyx used, contrast load, radiation dose, or fluoroscopy time. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  19. Initial experience with dual-lumen balloon catheter injection for preoperative Onyx embolization of skull base paragangliomas.

    PubMed

    Ladner, Travis R; He, Lucy; Davis, Brandon J; Yang, George L; Wanna, George B; Mocco, J

    2016-06-01

    OBJECT Paragangliomas are highly vascular head and neck tumors for which preoperative embolization is often considered to facilitate resection. The authors evaluated their initial experience using a dual-lumen balloon to facilitate preoperative embolization in 5 consecutive patients who underwent preoperative transarterial Onyx embolization assisted by the Scepter dual-lumen balloon catheter between 2012 and 2014. OBJECT The authors reviewed the demographic and clinical records of 5 patients who underwent Scepter-assisted Onyx embolization of a paraganglioma followed by resection between 2012 and 2014. Descriptive statistics of clinical outcomes were assessed. RESULTS Five patients (4 with a jugular and 1 with a vagal paraganglioma) were identified. Three paragangliomas were embolized in a single session, and each of the other 2 were completed in 3 staged sessions. The mean volume of Onyx used was 14.3 ml (range 6-30 ml). Twenty-seven vessels were selectively catheterized for embolization. All patients required selective embolization via multiple vessels. Two patients required sacrifice of parent vessels (1 petrocavernous internal carotid artery and 1 vertebral artery) after successful balloon test occlusion. One patient underwent embolization with Onyx-18 alone, 2 with Onyx-34 alone, and 1 with Onyx-18 and -34. In each case, migration of Onyx was achieved within the tumor parenchyma. The mean time between embolization and resection was 3.8 days (range 1-8 days). Gross-total resection was achieved in 3 (60%) patients, and the other 2 patients had minimal residual tumor. The mean estimated blood loss during the resections was 556 ml (range 200-850 ml). The mean postoperative hematocrit level change was -17.3%. Two patients required blood transfusions. One patient, who underwent extensive tumor penetration with Onyx, developed a temporary partial cranial nerve VII palsy that resolved to House-Brackmann Grade I (out of VI) at the 6-month follow-up. One patient

  20. Attitudes on and usage of balloon catheter technology in rhinology: A survey of the American Rhinologic Society.

    PubMed

    Halderman, Ashleigh A; Stokken, Janalee; Momin, Suhael R; Smith, Timothy L; Sindwani, Raj

    2015-01-01

    Use of balloon catheter dilation in the management of paranasal sinus diseases, including chronic rhinosinusitis (CRS) and recurrent acute rhinosinusitis, remains controversial. In an effort to gain some clarity about its evolving role, we surveyed members of the American Rhinologic Society (ARS). Online survey. ARS Members were sent an invitation by e-mail to participate in an online, anonymous 23-item survey. A total of 231 participants completed the survey, for an overall response rate of 25%. Balloon catheter technology (BCT) played no role in the practices of one-third of all the respondents. Of those who did use BCT, more than 50% performed only 1-4 cases per month on average. This did not differ significantly with practice type (p = 0.2988). The overall use of BCT differed between types of practices with those in private practice reporting greater use of the technology for maxillary and sphenoid sinuses (p = 0.0003 and p = 0.0073, respectively). Participants in private practice appeared significantly more impressed with the results of BCT when compared with those in academia (p = 0.0005) and also thought that patients were more satisfied (p = 0.0002). Opinions toward the strength of available evidence also differed significantly between the two groups (p = 0.0007). Thirty-two respondents had experienced a complication with BCT, although the majority of these did not require any intervention. ARS members surveyed used BCT infrequently in their practices. Attitudes on the role of this technology in CRS management differed between academic and private practitioners, but, despite this, the volume of reported BCT use was the same. Surgeons are more accepting of the technology now compared with 5 years ago, and many of them believe that their use of BCT will increase in the future.

  1. Detecting DNA synthesis of neointimal formation after catheter balloon injury in GK and in Wistar rats: using 5-ethynyl-2'-deoxyuridine.

    PubMed

    Guo, Jingsheng; Li, Dongye; Bai, Shiru; Xu, Tongda; Zhou, Zhongmin; Zhang, Yanbin

    2012-12-13

    Neointimal formation plays an important role in the pathogenesis of coronary restenosis after percutaneous coronary intervention (PCI), especially in patients with diabetes mellitus. Recently, some studies have shown that 5-ethynyl-2'-deoxyuridine (EdU) incorporation can serve as a novel alternative to the 5-bromo-2'-deoxyuridine (BrdU) antibody detection method for detection of DNA synthesis in regenerating avian cochlea, chick embryo and the adult nervous system. However, few studies have been performed to assess the suitability of EdU for detecting DNA synthesis in vascular neointima. The carotid artery balloon injury model was established in Goto-Kakizaki (GK) and Wistar rats. A Cell-LightTM EdU Kit was used to detect EdU-labeled cell nuclei of common carotid arteries at day 7 after catheter balloon injury. Different methods of injecting EdU were tested. The protein levels of proliferating cell nuclear antigen (PCNA) and p-Akt (Ser473), as well as the mRNA levels of PCNA were evaluated by Western blotting and quantitative real-time PCR (qRT-PCR), respectively. Immunohistochemical staining was also employed to visualize PCNA-positive cells. At day 7 after catheter balloon injury, far more EdU-positive and PCNA-positive cells were observed in GK rats. When comparing groups that received different EdU doses, it was found that the percentage of EdU-positive cells at a dose of 100 mg/kg body weight was than at doses of 25 mg/kg and 50 mg/kg. The number of positive cells was significantly higher in the repeated injection group compared to the single injection group. Further, after balloon injury DNA synthesis in GK rats was more notable than in Wistar rats. Neointimal formation in GK rats was more obvious than in Wistar rats. The protein levels of PCNA and p-Akt (Ser473) and the mRNA levels of PCNA were increased in injured rats as compared to uninjured rats, and were significantly higher in GK rats than in Wistar rats. By intraperitoneal injections of EdU at a dose

  2. Coronary angioplasty with second generation Monorail catheters.

    PubMed

    Pande, A K; Meier, B; Urban, P; Villavicencio, R; de la Serna, F; Moles, V

    1991-07-01

    The Monorail system (Schneider) consists of a balloon catheter in which the guidewire passes through the balloon itself, exits the catheter proximal to the balloon, and runs alongside its small shaft (3 French) through the length of the guiding catheter. It offers distinct advantages over conventional systems of coronary angioplasty. It facilitates contrast injections and permits rapid balloon exchanges. This system was used for coronary angioplasty in 273 unselected consecutive patients (age 59 +/- 10, mean 35 to 73 years). There were 216 patients (84%) undergoing single-vessel and 57 patients (16%) with multi-vessel coronary angioplasty. A total of 335 coronary stenoses were dilated, which included 35 total occlusions. The size of balloon used ranged from 2.0 to 4.25 mm (3.0 +/- 0.5 mm) and the severity of stenosis was 85 +/- 11%. Technical success was defined as a residual stenosis of less than 50% as determined angiographically. Clinical success was defined as technical success, and absence of a major inhospital complication defined as absence of myocardial infarction, lack of need for coronary arterial bypass surgery, and survival. The Monorail system was technically successful in 294/300 stenotic lesions (98%). It was clinically successful for 281 lesions (94%). Of the 35 total occlusions, technical success was obtained in 25 (71%). The residual stenosis of successful cases was 26 +/- 21%. The Monorail system was also successful in 5 patients with stenosis of more than 90% in whom conventional systems failed. The complications included acute occlusion causing acute myocardial infarction in 13 cases (5%), emergency coronary arterial bypass surgery in 1 patient (0.4%), and death in 4 patients (1.5%).(ABSTRACT TRUNCATED AT 250 WORDS)

  3. Optimizing logistics for balloon-occluded retrograde transvenous obliteration (BRTO) of gastric varices by doing away with the indwelling balloon: concept and techniques.

    PubMed

    Saad, Wael E; Nicholson, David B

    2013-06-01

    Since the conception of balloon-occluded retrograde transvenous obliteration (BRTO) of gastric varices 25 years ago, the placement of an indwelling balloon for hours has been central to the BRTO procedure. Numerous variables and variations of the BRTO procedure have been described, including methods to reduce sclerosant, combining percutaneous transhepatic obliteration, varying sclerosant, and using multiple sclerosants within the same procedure. However, the consistent feature of BRTO has always remained the indwelling balloon. Placing an indwelling balloon over hours for the BRTO procedure is a logistical burden that taxes the interventional radiology team and hospital resources. Substituting the balloon with hardware (coils or Amplatzer vascular plugs [AVPs] or both) is technically feasible and its risks most likely correlate with gastrorenal shunt (GRS) size. The current authors use packed 0.018- or 0.035-in coils or both for small gastric variceal systems (GRS size A and B) and AVPs for GRS sizes up to size E (from size A-E). The current authors recommend an indwelling balloon (no hardware substitute) for very large gastric variceal system (GRS size F). Substituting the indwelling balloon for hardware in size F and potentially size E GRS can also be risky. The current article describes the techniques of placing up to 16-mm AVPs through balloon occlusion guide catheters and then deflating the balloon once it has been substituted with the AVPs. In addition, 22-mm AVPs can be placed through sheaths once the balloon occlusion catheters are removed to further augment the 16-mm Amplatzer occlusion. To date, there are no studies describing, let alone evaluating, the clinical feasibility of performing BRTO without indwelling balloons. The described techniques have been successfully performed by the current authors. However, the long-term safety and effectiveness of these techniques is yet to be determined. Copyright © 2013 Elsevier Inc. All rights reserved.

  4. Paraspinal arteriovenous malformation Onyx embolization via an Ascent balloon.

    PubMed

    Martínez-Galdámez, Mario; Rodriguez-Arias, Carlos A; Utiel, Elena; Arreba, Emilio; Gonzalo, Miguel; Arenillas, Juan F

    2013-03-22

    Purely extradural lumbar spinal arteriovenous malformations (AVMs) are rare lesions that have diverse presentations and imaging features. The treatment of a symptomatic high flow paraspinal AVM with multiple feeders remains a challenge. We report the first use of an Ascent balloon (dual lumen balloon catheter) to deliver Onyx with excellent penetration to a paraspinal AVM.

  5. Paraspinal arteriovenous malformation Onyx embolization via an Ascent balloon.

    PubMed

    Martínez-Galdámez, Mario; Rodriguez-Arias, Carlos A; Utiel, Elena; Arreba, Emilio; Gonzalo, Miguel; Arenillas, Juan F

    2014-04-01

    Purely extradural lumbar spinal arteriovenous malformations (AVMs) are rare lesions that have diverse presentations and imaging features. The treatment of a symptomatic high flow paraspinal AVM with multiple feeders remains a challenge. We report the first use of an Ascent balloon (dual lumen balloon catheter) to deliver Onyx with excellent penetration to a paraspinal AVM.

  6. Efficacy of Intrauterine Bakri Balloon Tamponade in Cesarean Section for Placenta Previa Patients.

    PubMed

    Cho, Hee Young; Park, Yong Won; Kim, Young Han; Jung, Inkyung; Kwon, Ja-Young

    2015-01-01

    The aims of this study were to analyze the predictive factors for the use of intrauterine balloon insertion and to evaluate the efficacy and factors affecting failure of uterine tamponade with a Bakri balloon during cesarean section for abnormal placentation. We reviewed the medical records of 137 patients who underwent elective cesarean section for placenta previa between July 2009 and March 2014. Cesarean section and Bakri balloon insertion were performed by a single qualified surgeon. The Bakri balloon was applied when blood loss during cesarean delivery exceeded 1,000 mL. Sixty-four patients (46.7%) required uterine balloon tamponade during cesarean section due to postpartum bleeding from the lower uterine segment, of whom 50 (78.1%) had placenta previa totalis. The overall success rate was 75% (48/64) for placenta previa patients. Previous cesarean section history, anterior placenta, peripartum platelet count, and disseminated intravascular coagulopathy all significantly differed according to balloon success or failure (all p<0.05). The drainage amount over 1 hour was 500 mL (20-1200 mL) in the balloon failure group and 60 mL (5-500 mL) in the balloon success group (p<0.01). Intrauterine tamponade with a Bakri balloon is an adequate adjunct management for postpartum hemorrhage following cesarean section for placenta previa to preserve the uterus. This method is simple to apply, non-invasive, and inexpensive. However, possible factors related to failure of Bakri balloon tamponade for placenta previa patients such as prior cesarean section history, anterior placentation, thrombocytopenia, presence of DIC at the time of catheter insertion, and catheter drainage volume more than 500 mL within 1 hour of catheter placement should be recognized, and the next-line management should be prepared in advance.

  7. Efficacy of Intrauterine Bakri Balloon Tamponade in Cesarean Section for Placenta Previa Patients

    PubMed Central

    Cho, Hee Young; Park, Yong Won; Kim, Young Han; Jung, Inkyung; Kwon, Ja-Young

    2015-01-01

    Purpose The aims of this study were to analyze the predictive factors for the use of intrauterine balloon insertion and to evaluate the efficacy and factors affecting failure of uterine tamponade with a Bakri balloon during cesarean section for abnormal placentation. Methods We reviewed the medical records of 137 patients who underwent elective cesarean section for placenta previa between July 2009 and March 2014. Cesarean section and Bakri balloon insertion were performed by a single qualified surgeon. The Bakri balloon was applied when blood loss during cesarean delivery exceeded 1,000 mL. Results Sixty-four patients (46.7%) required uterine balloon tamponade during cesarean section due to postpartum bleeding from the lower uterine segment, of whom 50 (78.1%) had placenta previa totalis. The overall success rate was 75% (48/64) for placenta previa patients. Previous cesarean section history, anterior placenta, peripartum platelet count, and disseminated intravascular coagulopathy all significantly differed according to balloon success or failure (all p<0.05). The drainage amount over 1 hour was 500 mL (20–1200 mL) in the balloon failure group and 60 mL (5–500 mL) in the balloon success group (p<0.01). Conclusion Intrauterine tamponade with a Bakri balloon is an adequate adjunct management for postpartum hemorrhage following cesarean section for placenta previa to preserve the uterus. This method is simple to apply, non-invasive, and inexpensive. However, possible factors related to failure of Bakri balloon tamponade for placenta previa patients such as prior cesarean section history, anterior placentation, thrombocytopenia, presence of DIC at the time of catheter insertion, and catheter drainage volume more than 500 mL within 1 hour of catheter placement should be recognized, and the next-line management should be prepared in advance. PMID:26263014

  8. Paraspinal arteriovenous malformation Onyx embolization via an Ascent balloon

    PubMed Central

    Martínez-Galdámez, Mario; Rodriguez-Arias, Carlos A; Utiel, Elena; Arreba, Emilio; Gonzalo, Miguel; Arenillas, Juan F

    2013-01-01

    Purely extradural lumbar spinal arteriovenous malformations (AVMs) are rare lesions that have diverse presentations and imaging features. The treatment of a symptomatic high flow paraspinal AVM with multiple feeders remains a challenge. We report the first use of an Ascent balloon (dual lumen balloon catheter) to deliver Onyx with excellent penetration to a paraspinal AVM. PMID:23524491

  9. Biofilm Formation by Pseudomonas Species Onto Graphene Oxide-TiO2 Nanocomposite-Coated Catheters: In vitro Analysis

    NASA Astrophysics Data System (ADS)

    Deb, Ananya; Vimala, R.

    The present study focuses on the development of an in vitro model system for biofilm growth by Pseudomonas aerouginosa onto small discs of foley catheter. Catheter disc used for the study was coated with graphene oxide-titanium oxide composite (GO-TiO2) and titanium oxide (TiO2) and characterized through XRD, UV-visible spectroscopy. Morphological analysis was done by scanning electron microscopy (SEM). The biofilm formed on the catheter surface was quantified by crystal violet (CV) staining method and a colorimetric assay (MTT assay) which involves the reduction of tetrazolium salt. The catheter coated with GO-TiO2 showed reduced biofilm growth in comparison to the TiO2-coated and uncoated catheter, thus indicating that it could be successfully used in coating biomedical devices to prevent biofilm formation which is a major cause of nosocomial infection.

  10. Radioactive 133-Xenon gas-filled balloon to prevent restenosis: dosimetry, efficacy, and safety considerations.

    PubMed

    Apple, Marc; Waksman, Ron; Chan, Rosanna C; Vodovotz, Yoram; Fournadjiev, Jana; Bass, Bill G

    2002-08-06

    Ionizing radiation administered intraluminally via catheter-based systems using solid beta and gamma sources or liquid-filled balloons has shown reduction in the neointima formation after injury in the porcine model. We propose a novel system that uses a 133-Xenon (133Xe) radioactive gas-filled balloon catheter system. Overstretch balloon injury was performed in the coronary arteries of 33 domestic pigs. A novel 133Xe radioactive gas-filled balloon (3.5/45 mm) was positioned to overlap the injured segment with margins. After vacuum was obtained in the balloon catheter, approximately 2.5 cc of 133Xe gas was injected to fill the balloon. Doses of 0, 7.5, 15, and 30 Gy were delivered to a distance of 0.25 mm from the balloon surface. The dwell time ranged from 1.0 to 4.0 minutes, depending on the dose. Localization of 133Xe in the balloon was verified by a gamma camera. The average activity in a 3.5/45-mm balloon was measured at 67.7+/-12.1 mCi, and the total diffusion loss of the injected dose was 0.26% per minute of the injected dose. Bedside radiation exposure measured between 2 and 6 mR/h, and the shallow dose equivalent was calculated as 0.037 mrem per treatment. Histomorphometric analysis at 2 weeks showed inhibition of the intimal area (intimal area corrected for medial fracture length [IA/FL]) in the irradiated segments of 0.26+/-0.08 with 30 Gy, 0.07+/-0.24 with 15 Gy, and 0.12+/-0.89 with 7.5 Gy versus 0.76+/-0.08 with control P<0.001. 133Xe gas-filled balloon is feasible and effective in the reduction of neointima formation in the porcine model and safe for use in coronary arteries.

  11. Epicardial phrenic nerve displacement during catheter ablation of atrial and ventricular arrhythmias: procedural experience and outcomes.

    PubMed

    Kumar, Saurabh; Barbhaiya, Chirag R; Baldinger, Samuel H; Koplan, Bruce A; Maytin, Melanie; Epstein, Laurence M; John, Roy M; Michaud, Gregory F; Tedrow, Usha B; Stevenson, William G

    2015-08-01

    Arrhythmia origin in close proximity to the phrenic nerve (PN) can hinder successful catheter ablation. We describe our approach with epicardial PN displacement in such instances. PN displacement via percutaneous pericardial access was attempted in 13 patients (age 49±16 years, 9 females) with either atrial tachycardia (6 patients) or atrial fibrillation triggered from a superior vena cava focus (1 patient) adjacent to the right PN or epicardial ventricular tachycardia origin adjacent to the left PN (6 patients). An epicardially placed steerable sheath/4 mm-catheter combination (5 patients) or a vascular or an esophageal balloon (8 patients) was ultimately successful. Balloon placement was often difficult requiring manipulation via a steerable sheath. In 2 ventricular tachycardia cases, absence of PN capture was achieved only once the balloon was directly over the ablation catheter. In 3 atrial tachycardia patients, PN displacement was not possible with a balloon; however, a steerable sheath/catheter combination was ultimately successful. PN displacement allowed acute abolishment of all targeted arrhythmias. No PN injury occurred acutely or in follow up. Two patients developed acute complications (pleuro-pericardial fistula 1 and pericardial bleeding 1). Survival free of target arrhythmia was achieved in all atrial tachycardia patients; however, a nontargeted ventricular tachycardia recurred in 1 patient at a median of 13 months' follow up. Arrhythmias originating in close proximity to the PN can be targeted successfully with PN displacement with an epicardially placed steerable sheath/catheter combination, or balloon, but this strategy can be difficult to implement. Better tools for phrenic nerve protection are desirable. © 2015 American Heart Association, Inc.

  12. [Results of urethral reconstruction in adults after multiple hypospadias repairs].

    PubMed

    Gamidov, S I; Shneiderman, M G; Pushkar, D Yu; Vasil'ev, A O; Govorov, A V; Ovchinnikov, R I; Popova, A Yu; Dusmukhamedov, R D

    2017-06-01

    To improve treatment results in patients after multiple hypospadias repairs by optimizing the postoperative management. Eighty-two patients (mean age 48.1+/-15.3 years) with urethral strictures secondary to failed hypospadias repairs underwent staged graft urethroplasty using oral mucosa (cheek, lip, tongue) as a grafting material. In 62 patients, at the end of surgery the bladder was drained with a standard Foley catheter. In twenty patients the bladder was drained with a modified silicone urethral catheter, which had an additional channel for delivering drugs and removing the urethral wound effluent, and a second additional channel for inflating a balloon fixed to the catheter tube at different parts of the catheter. The mean length of the stricture was 5.4+/-1.2 cm (from 1 to 16 cm). Twenty-eight patients had postoperative complications. Using the modified catheter resulted in statistically significantly (p<0.05) smaller percentage of complications (10% vs 41.9%) compared to standard Foley catheter. Urinalysis and sperm test on the follow up examination at 12 months showed that only 9 (10.9%) patients had signs of the inflammatory process. Seventy-five patients (91.5%) rated the appearance of the penis as "good"; only 5 (6.1%) and 2 (2.4%) patients considered the result as "satisfactory" and "unsatisfactory", respectively. Eighty patient (97.6%) regarded the treatment result as "good" for the quality of urination and only two (2.4%) considered it "satisfactory". When assessing the strength of urinary stream, 64 (78.1%), 13 (15.8%) and 5 (6.1%) patients rated it as "good", "satisfactory", and "unsatisfactory", respectively. The study findings shows that staged urethroplasty using the oral mucosa restores the urethral patency, reduces the severity of the inflammatory process, thus improving the quality of life of patients after failed hypospadias repair. The proposed modification of the catheter ensures the timely delivery of drugs to the surgical site, evacuation

  13. Multicenter Cohort Study to Assess the Impact of a Silver-Alloy and Hydrogel-Coated Urinary Catheter on Symptomatic Catheter-Associated Urinary Tract Infections

    PubMed Central

    Lederer, James W.; Jarvis, William R.; Thomas, Lendon

    2014-01-01

    PURPOSE: The purpose of this study was to determine the effect of a silver-alloy hydrogel catheter on symptomatic catheter-associated urinary tract infections (CAUTIs). DESIGN: Multicenter before-after non-randomized cohort study. SUBJECTS AND SETTING: Seven acute care hospitals ranging in size from 124 to 607 beds participated in this study. The study population included adult patients with a positive urine culture 2 or more days after admission, who underwent Foley catheterization. METHODS: Catheter-associated urinary tract infection surveillance was conducted at each hospital for at least 3 months during the use of a standard catheter and 3 months during the use of the silver-alloy hydrogel catheter. Both the National Healthcare Safety Network (NHSN) surveillance and a clinical definition of CAUTI were used for rate calculation. RESULTS: A 47% relative reduction in the CAUTI rate was observed with the silver-alloy hydrogel catheter compared to the standard catheter when both infection definitions were used (0.945/1000 patient days vs 0.498/1000 patient days) (odds ratio = 0.53; P < .0001; 95% CI: 0.45–0.62). When only NHSN-defined CAUTIs were considered, a 58% relative reduction occurred in the silver-alloy hydrogel period (0.60/1000 patient days vs 0.25/1000 patient days) (odds ratio = 0.42; P < .0001; 95% CI: 0.34–0.53). Antimicrobial days for CAUTIs decreased from 1165 (standard catheter period) to 406 (silver-alloy hydrogel period). CONCLUSIONS: Use of a silver-alloy hydrogel urinary catheter reduced symptomatic CAUTI occurrences as defined by both NHSN and clinical criteria. PMID:24922561

  14. A Stent-Retrieving into an Aspiration Catheter with Proximal Balloon (ASAP) Technique: A Technique of Mechanical Thrombectomy.

    PubMed

    Goto, Shunsaku; Ohshima, Tomotaka; Ishikawa, Kojiro; Yamamoto, Taiki; Shimato, Shinji; Nishizawa, Toshihisa; Kato, Kyozo

    2018-01-01

    The best technique for the first attempt at mechanical thrombectomy for acute ischemic stroke is a still matter of debate. In this study, we evaluate the efficacy of a stent-retrieving into an aspiration catheter with proximal balloon (ASAP) technique that uses a series of thrombus extraction by withdrawing the stent retriever into the aspiration catheter and continuous aspiration from the aspiration catheter at the first attempt. We performed a retrospective analysis of 42 consecutive patients with acute ischemic stroke caused by occlusions in the anterior circulation who were treated with the ASAP technique at our institution. Preoperative patient characteristic, including age, thrombus location, Alberta Stroke Program Early CT Score, National Institutions of Health Stroke Scale, and time from onset to puncture; postoperative Thrombolysis in Cerebral Infarction score; modified Rankin Scale score after 3 months; time from puncture to recanalization; the number of passes to achieve recanalization; and procedural complications, including intracranial hemorrhage, embolization to new territory, and distal embolization, were assessed. A Thrombolysis in Cerebral Infarction score of 2B or 3 was achieved in 40/42 patients (95.2%). Average time from puncture to the final recanalization was 21.5 minutes. Recanalization was achieved in a single attempt in 31 patients (77.5%). Embolization to new territory was observed in only 2 patients (4.8%); no patient developed distal embolization or intracranial hemorrhage including asymptomatic subarachnoid hemorrhage. Thirty-two patients (76.2%) achieved modified Rankin Scale scores of 0-2 at 3 months postoperatively. Our ASAP technique showed fast recanalization, minimal complications, and good clinical outcomes in this case series. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. [A simple model for describing pressure-volume curves in free balloon dilatation with reference the dynamics of inflation hydraulic aspects].

    PubMed

    Bloss, P; Werner, C

    2000-06-01

    We propose a simple model to describe pressure-time and pressure-volume curves for the free balloon (balloon in air) of balloon catheters, taking into account the dynamics of the inflation device. On the basis of our investigations of the flow rate-dependence of characteristic parameters of the pressure-time curves, the appropriateness of this simple model is demonstrated using a representative example. Basic considerations lead to the following assumptions: (1) the flow within the shaft of the catheter is laminar, and (ii) the volume decrease of the liquid used for inflation due to pressurization can be neglected if the liquid is carefully degassed prior to inflation, and if the total volume of the liquid in the system is less than 2 ml. Taking into account the dynamics of the inflation device used for pumping the liquid into the proximal end of the shaft during inflation, the inflation process can be subdivided into the following three phases: initial phase, filling phase and dilatation phase. For these three phases, the transformation of the time into the volume coordinates is given. On the basis of our model, the following parameters of the balloon catheter can be determined from a measured pressure-time curve: (1) the resistance to flow of the liquid through the shaft of the catheter and the resulting pressure drop across the shaft, (2) the residual volume and residual pressure of the balloon, and (3) the volume compliance of the balloon catheter with and without the inflation device.

  16. Complicated catheter-associated urinary tract infections due to Escherichia coli and Proteus mirabilis.

    PubMed

    Jacobsen, S M; Stickler, D J; Mobley, H L T; Shirtliff, M E

    2008-01-01

    Catheter-associated urinary tract infections (CAUTIs) represent the most common type of nosocomial infection and are a major health concern due to the complications and frequent recurrence. These infections are often caused by Escherichia coli and Proteus mirabilis. Gram-negative bacterial species that cause CAUTIs express a number of virulence factors associated with adhesion, motility, biofilm formation, immunoavoidance, and nutrient acquisition as well as factors that cause damage to the host. These infections can be reduced by limiting catheter usage and ensuring that health care professionals correctly use closed-system Foley catheters. A number of novel approaches such as condom and suprapubic catheters, intermittent catheterization, new surfaces, catheters with antimicrobial agents, and probiotics have thus far met with limited success. While the diagnosis of symptomatic versus asymptomatic CAUTIs may be a contentious issue, it is generally agreed that once a catheterized patient is believed to have a symptomatic urinary tract infection, the catheter is removed if possible due to the high rate of relapse. Research focusing on the pathogenesis of CAUTIs will lead to a better understanding of the disease process and will subsequently lead to the development of new diagnosis, prevention, and treatment options.

  17. Complicated Catheter-Associated Urinary Tract Infections Due to Escherichia coli and Proteus mirabilis

    PubMed Central

    Jacobsen, S. M.; Stickler, D. J.; Mobley, H. L. T.; Shirtliff, M. E.

    2008-01-01

    Catheter-associated urinary tract infections (CAUTIs) represent the most common type of nosocomial infection and are a major health concern due to the complications and frequent recurrence. These infections are often caused by Escherichia coli and Proteus mirabilis. Gram-negative bacterial species that cause CAUTIs express a number of virulence factors associated with adhesion, motility, biofilm formation, immunoavoidance, and nutrient acquisition as well as factors that cause damage to the host. These infections can be reduced by limiting catheter usage and ensuring that health care professionals correctly use closed-system Foley catheters. A number of novel approaches such as condom and suprapubic catheters, intermittent catheterization, new surfaces, catheters with antimicrobial agents, and probiotics have thus far met with limited success. While the diagnosis of symptomatic versus asymptomatic CAUTIs may be a contentious issue, it is generally agreed that once a catheterized patient is believed to have a symptomatic urinary tract infection, the catheter is removed if possible due to the high rate of relapse. Research focusing on the pathogenesis of CAUTIs will lead to a better understanding of the disease process and will subsequently lead to the development of new diagnosis, prevention, and treatment options. PMID:18202436

  18. Placenta accreta and balloon catheterization: the experience of a single center and an update of latest evidence of literature.

    PubMed

    Gulino, Ferdinando Antonio; Guardo, F Di; Zambrotta, E; Di Gregorio, L M; Miranda, Andrea; Capriglione, Stella; Palumbo, M A

    2018-05-18

    We studied the efficacy of using pre-cesarean delivery (CD) temporary occlusion of internal iliac arteries with balloon catheters in case of placenta previa-accreta in terms of maternal and neonatal outcomes and to test accuracy of ultrasound (US) and magnetic resonance imaging (MRI) for prenatal diagnosis. From March 2014 to January 2018, women with an US and/or MRI diagnosis of placenta previa-accreta and a planned delivery were enrolled and divided into two groups: balloon catheterization group (women treated with preoperative catheters and CD) and control group (women candidates to elective CD). 37 patients were enrolled: 16 in balloon catheterization group and 21 in control group. Significant differences were detected in estimated blood loss. Prophylactic balloon catheterization could reduce intraoperative red blood cell transfusion. The incidence of hysterectomy was lower in balloon group. No statistical difference was found for neonatal outcomes. Both US and MRI have showed to be useful and complementary to diagnose placenta previa-accreta. Temporal, perioperative, and prophylactic positioning of balloon vascular catheters is an effective method for managing severe hemorrhage caused by placenta previa-accreta as it reduced intraoperative blood loss, lessened perioperative hemostatic measures and intraoperative red cell transfusions, and reduced hysterectomies.

  19. Novel paclitaxel-coated angioplasty balloon catheter based on cetylpyridinium salicylate: preparation, characterization and simulated use in an in vitro vessel model.

    PubMed

    Petersen, Svea; Kaule, Sebastian; Stein, Florian; Minrath, Ingo; Schmitz, Klaus-Peter; Kragl, Udo; Sternberg, Katrin

    2013-10-01

    Drug-coated balloons (DCB), which have emerged as therapeutic alternative to drug-eluting stents in percutaneous cardiovascular intervention, are well described with regard to clinical efficiency and safety within a number of clinical studies. In vitro studies elucidating the correlation of coating method and composition with DCB performance are however rare but considered important for the understanding of DCB requirements and the improvement of established DCB. In this context, we evaluated the applicability of a pipetting, dip-coating, and spray-coating process for the establishment of DCB based on paclitaxel (PTX) and the ionic liquid cetylpyridinium salicylate (Cetpyrsal) as novel innovative additive in three different compositions. Among tested methods and compositions, the pipetting process with 50 wt.% PTX resulted in most promising coatings as drug load was less controllable by the other processes and higher PTX contents led to considerable drug crystallization, as visualized by electron microscopy, accelerating PTX loss during short-term elution. Applying these conditions, homogeneous coatings could be applied on balloon catheter, whose simulated use in an in vitro vessel model revealed percental drug losses of 36 and 28% during transit and percental drug transfers of 12 and 40% under expansion for coatings applied in expanded and folded balloon condition, respectively. In comparison to literature values, these results support the high potential of Cetpyrsal as novel DCB matrix regarding low drug loss and efficient drug transfer. © 2013.

  20. Ureteral Stents and Foley Catheters-Associated Urinary Tract Infections: The Role of Coatings and Materials in Infection Prevention

    PubMed Central

    Lo, Joey; Lange, Dirk; Chew, Ben H.

    2014-01-01

    Urinary tract infections affect many patients, especially those who are admitted to hospital and receive a bladder catheter for drainage. Catheter associated urinary tract infections are some of the most common hospital infections and cost the health care system billions of dollars. Early removal is one of the mainstays of prevention as 100% of catheters become colonized. Patients with ureteral stents are also affected by infection and antibiotic therapy alone may not be the answer. We will review the current evidence on how to prevent infections of urinary biomaterials by using different coatings, new materials, and drug eluting technologies to decrease infection rates of ureteral stents and catheters. PMID:27025736

  1. Ureteral Stents and Foley Catheters-Associated Urinary Tract Infections: The Role of Coatings and Materials in Infection Prevention.

    PubMed

    Lo, Joey; Lange, Dirk; Chew, Ben H

    2014-03-10

    Urinary tract infections affect many patients, especially those who are admitted to hospital and receive a bladder catheter for drainage. Catheter associated urinary tract infections are some of the most common hospital infections and cost the health care system billions of dollars. Early removal is one of the mainstays of prevention as 100% of catheters become colonized. Patients with ureteral stents are also affected by infection and antibiotic therapy alone may not be the answer. We will review the current evidence on how to prevent infections of urinary biomaterials by using different coatings, new materials, and drug eluting technologies to decrease infection rates of ureteral stents and catheters.

  2. Instrumented urethral catheter and its ex vivo validation in a sheep urethra

    NASA Astrophysics Data System (ADS)

    Ahmadi, Mahdi; Rajamani, Rajesh; Timm, Gerald; Sezen, Serdar

    2017-03-01

    This paper designs and fabricates an instrumented catheter for instantaneous measurement of distributed urethral pressure profiles. Since the catheter enables a new type of urological measurement, a process for accurate ex vivo validation of the catheter is developed. A flexible sensor strip is first fabricated with nine pressure sensors and integrated electronic pads for an associated sensor IC chip. The flexible sensor strip and associated IC chip are assembled on a 7 Fr Foley catheter. A sheep bladder and urethra are extracted and used in an ex vivo set up for verification of the developed instrumented catheter. The bladder-urethra are suspended in a test rig and pressure cuffs placed to apply known static and dynamic pressures around the urethra. A significant challenge in the performance of the sensor system is the presence of parasitics that introduce large bias and drift errors in the capacitive sensor signals. An algorithm based on use of reference parasitic transducers is used to compensate for the parasitics. Extensive experimental results verify that the developed compensation method works effectively. Results on pressure variation profiles circumferentially around the urethra and longitudinally along the urethra are presented. The developed instrumented catheter will be useful in improved urodynamics to more accurately diagnose the source of urinary incontinence in patients.

  3. Temporary Percutaneous Aortic Balloon Occlusion to Enhance Fluid Resuscitation Prior to Definitive Embolization of Post-Traumatic Liver Hemorrhage

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Matsuoka, Shin; Uchiyama, Katsuhiro; Shima, Hideki

    2001-07-15

    We successfully stabilized severe hemorrhagic shock following traumatic liver injury by percutaneous transcarotid supraceliac aortic occlusion with a 5 Fr balloon catheter. Then we were able to perform transfemoral embolization therapy of the hepatic arterial bleeding source. Transient aortic occlusion using a balloon catheter appears to be a useful adjunct in select cases where stabilization of the patient is necessary to allow successful selective embolization of the bleeding source.

  4. Temporary subclavian steal to reduce intraprocedural embolic risk during detachable balloon occlusion of vertebrobasilar aneurysms: technical note with two case reports.

    PubMed

    Eckard, D A; O'Boynick, P L; Han, P P

    1996-11-01

    Unintentional intracerebral embolization is a serious, ever present threat during neurointerventional procedures. We have devised a method to reduce this intraprocedural risk in vertebral artery interventions by creating a temporary subclavian steal. For this technique, a temporary balloon occlusion catheter is advanced into the proximal subclavian artery via a femoral artery approach, while a second introducer catheter is passed into the target vertebral artery via an axillary artery access. The temporary occluding balloon is then inflated within the proximal subclavian artery, establishing a subclavian steal that diverts blood flow into the arm. Permanent balloon occlusion of the vertebral artery can then be accomplished without fear of intracerebral embolization. Two patients with vertebrobasilar junction aneurysms were successfully treated with detachable balloon embolization using this cerebral protection technique. The permanent occlusion balloons were easily passed through the introducer catheter without difficulty despite reversed vertebral artery flow. No complications were encountered, and the aneurysms were successfully occluded in both patients. Temporary subclavian steal can be easily created to reduce the risk of cerebral embolic complications when performing interventional neuroradiological procedures in the vertebral artery.

  5. CUA Annual Meeting Abstracts addition.

    PubMed

    2012-08-01

    : Foley catheters are assumed to drain the bladder to completion. We have previously shown that dependent loops along the drainage tubing create air-locks, which obstruct antegrade urine flow and result in un-drained residual bladder urine. We hypothesized that drainage characteristics of Foley catheters remain poorly understood by urologists and general surgeons. We conducted a nationwide survey of general surgery and urology training program faculty and residents, to assess perceptions of Foley catheter drainage. We designed a novel catheter drainage tube/bag that eliminates air-locks. : An anonymous illustrated questionnaire assessing Foley catheter use patterns and perception was sent to general surgery and urology residency programs (N=108) nationwide. A modified catheter drainage tube/bag unit was designed and tested. An ex vivo catheterized bladder model was designed to measure and compare urine drainage rates with the standard drainage system, versus with our novel design. : A total of 307 responses were collected from residents (55%) and faculty (45%); responses were similar among both groups (p<0.05). The majority reported that at their centers Foley catheter drainage tubes are generally positioned with a dependent loop (94.1%), and, that positioning with a dependent loop, versus without (78.1%) promoted optimal drainage. Antegrade drainage does not occur with a traditional drainage system when a >5.5 inch dependent loop in place. With our proposed design, which eliminates dependent loops, the bladder model emptied to completion consistently. : Traditional Foley catheter drainage systems, as commonly used, evacuate the bladder sub- optimally. More reliable and complete bladder drainage may decrease the incidence of catheter related UTI. The novel modified Foley catheter drainage tube/bag design presented here eliminates dependent loops, to optimize antegrade drainage.

  6. Factors confounding impedance catheter volume measurements in vitro.

    PubMed

    Bielefeld, M R; Cabreriza, S E; Spotnitz, H M

    1993-06-01

    The impedance catheter allows continuous measurement of ventricular volume. External influences have been described as causing parallel shifts in impedance-measured volumes; however, factors affecting impedance measurements in a nonparallel manner have not been fully characterized. Accordingly, an impedance catheter was placed inside a latex balloon into which known volumes of normal saline solution were injected. Conductive and nonconductive materials were individually placed within the balloon. Impedance was measured with materials touching (T) or not touching (NT) the catheter. Impedance-measured volumes were plotted versus actual volumes. Compared with the line of identity (LID), a statistical difference (p < 0.05) was found in the slopes in the presence of metallic objects only. These included a pacing lead (T, NT) (mT = 1.32m mNT = 1.29 versus mLID = 1.00), titanium (T) (mT = 1.68 versus mLID = 1.00), and aluminum (NT) (mNT = 0.72 versus mLID = 1.00). These changes in slope indicate nonparallel effects on impedance that confound the ability of the impedance catheter to determine volumes in vitro. These observations imply that serial calibration of both the slope constant (alpha) and the intercept (parallel conductance) of impedance may be necessary for in vivo measurements of ventricular volume based on impedance in the presence of metallic objects.

  7. Complication Rates and Patency of Radiologically Guided Mushroom Gastrostomy, Balloon Gastrostomy, and Gastrojejunostomy: A Review of 250 Procedures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yip, Doris; Vanasco, Matthew; Funaki, Brian

    2004-01-15

    To compare complication rates and tube performance of percutaneous mushroom gastrostomy, balloon gastrostomy, and gastrojejunostomy. Between September 9, 1999 and April 23, 2001, 203 patients underwent 250 radiologically guided percutaneous gastrostomy and gastrojejunostomy procedures. Follow-up was conducted through chart reviews and review of our interventional radiology database. Procedural and catheter-related complications were recorded. Chi-square statistical analysis was performed. In patients receiving mushroom-retained gastrostomy catheters (n = 114), the major complication rate was 0.88% (n = 1), the minor complication rate was 5.3% (n = 6), and the tube complication rate was 4.4% (n = 5). In patients receiving balloon-retained gastrostomymore » tubes (n = 67), the major complication rate was 0, the minor complication rate was 4.5% (n = 3), and the tube complication rate was 34.3% (n = 23). In patients receiving gastrojejunostomy catheters (n = 69), the major complication rate was 1.4% (n = 1), the minor complication rate was 2.9% (n = 2), and the tube complication rate was 34.8% (n = 24). No statistically significant differences were found between procedural or peri-procedural complications among the different types of tubes. Mushroom-retained catheters had significantly fewer tube complications (p < 0.01). Percutaneous gastrostomy and gastrojejunostomy have similar procedural and peri-procedural complication rates. Mushroom gastrostomy catheters have fewer tube-related complications compared with balloon gastrostomy and gastrojejunostomy catheters. In addition, mushroom-retained catheters exhibit the best overall long-term tube patency and are therefore the gastrostomy catheter of choice.« less

  8. Second-generation endometrial ablation technologies: the hot liquid balloons.

    PubMed

    Vilos, George A; Edris, Fawaz

    2007-12-01

    Hysteroscopic endometrial ablation (HEA) was introduced in the 1980s to treat menorrhagia. Its use required additional training, surgical expertise and specialized equipment to minimize emergent complications such as uterine perforations, thermal injuries and excessive fluid absorption. To overcome these difficulties and concerns, thermal balloon endometrial ablation (TBEA) was introduced in the 1990s. Four hot liquid balloons have been introduced into clinical practice. All systems consist of a catheter (4-10mm diameter), a silicone balloon and a control unit. Liquids used to inflate the balloons include internally heated dextrose in water (ThermaChoice, 87 degrees C), and externally heated glycine (Cavaterm, 78 degrees C), saline (Menotreat, 85 degrees ) and glycerine (Thermablate, 173 degrees C). All balloons require pressurization from 160 to 240 mmHg for treatment cycles of 2 to 10 minutes. Prior to TBEA, preoperative endometrial thinning, including suction curettage, is optional. Several RCTs and cohort studies indicate that the advantages of TBEA include portability, ease of use and short learning curve. In addition, small diameter catheters requiring minimal cervical dilatation (5-7 mm) and short duration of treatment cycles (2-8 min) allow treatment under minimal analgesia/anesthesia requirements in a clinic setting. Following TBEA serious adverse events, including thermal injuries to viscera have been experienced. To minimize such injuries some surgeons advocate the use of routine post-dilatation hysteroscopy and/or ultrasonography to confirm correct intrauterine placement of the balloon prior to initiating the treatment cycle. After 10 years of clinical practice, TBEA is thought to be the preferred first-line surgical treatment of menorrhagia in appropriately selected candidates. Economic modeling also suggested that TBEA may be more cost-effective than HEA.

  9. Spiculated Bladder Calculi: The Culprit for Repeated Catheter Failure

    PubMed Central

    Wek, C.; Fox, T. P.; Muir, G. H.

    2013-01-01

    We report on the case of a frustrated 90-year-old gentleman who was seen in the Accident and Emergency department for the third time in four days with failure of his long-term urethral catheter. He reported that the catheter simply “fell out” with the balloon deflated. On each occasion previously, the catheter had been reinserted in A&E and the patient discharged home. These repeated visits to A&E were understandably a source of much frustration for the patient and his family. On the third presentation, plain abdominal radiography demonstrated a large spiculated bladder calculus. PMID:23984173

  10. Post-Transurethral Resection of the Prostate Inflation of Pressure-Controlled Endorectal Balloon-Impact on Postoperative Bleeding: A Preliminary Experimental Pilot Study.

    PubMed

    Mohyelden, Khaled; Ibrahim, Hamdy; Abdel-Kader, Osman; Sherief, Mahmoud H; El-Nashar, Ahmed; Shaker, Hosam; Elkoushy, Mohamed A

    2016-02-01

    To evaluate the impact of rectal balloon (RB) inflation on post-transurethral resection of the prostate (TURP) bleeding in patients with symptomatic benign prostatic hyperplasia. After institutional review board approval, patients who were eligible for TURP were randomized into two equal groups, depending on whether they received postoperative endorectal balloon (RB) (GII) or not (GI). The tip of three-way Foley catheter was fixed to a balloon by a blaster strip to prepare air-tight RB. Postoperatively, the RB was inflated for 15 minutes by a pressure-controlled sphygmomanometer. Perioperative data were compared between both groups, including hemoglobin (Hb) deficit 24-hour postoperatively and at time of discharge. Functional outcomes, anorectal complaints, and adverse events were assessed perioperatively and after 1 and 3 months. Fifty patients were enrolled, including 13 (26%) patients who presented with indwelling urethral catheters. Baseline data and mean resected tissue weight were comparable between both groups, including preoperative Hb (p = 0.17). Immediate postoperative Hb deficit was, comparable between GI and GII patients (0.58 ± 0.18 vs 0.60 ± 0.2, p = 0.56) before RB inflation, respectively. However, compared to GI patients, mean Hb deficit significantly decreased in GII patients 24-hour postoperatively (0.2 ± 0.2 vs 0.7 ± 0.3 g, p = 0.002) and at time of discharge (0.8 ± 0.2 vs 1.3 ± 0.4 g, p = 0.003). GII patients needed significantly less postoperative irrigation (2.1 ± 1.6 vs 8.3 ± 1.8 L, p < 0.001), shorter catheterization time (2.3 ± 0.8 vs 3.8 ± 1.3 days, p < 0.001), and shorter hospital stay (2.6 ± 0.5 vs 4.3 ± 1.0 days, p < 0.001). Both groups were comparable in all functional outcomes at the most recent follow-up. Blood transfusion was needed in only one patient (4%) in GI. No patient needed recystoscopy for hematuria or clot retention in either

  11. A prospective interventional study to examine the effect of a silver alloy and hydrogel-coated catheter on the incidence of catheter-associated urinary tract infection.

    PubMed

    Chung, P Hy; Wong, C Wy; Lai, C Kc; Siu, H K; Tsang, D Nc; Yeung, K Y; Ip, D Km; Tam, P Kh

    2017-06-01

    Catheter-associated urinary tract infection is a major hospital-acquired infection. This study aimed to analyse the effect of a silver alloy and hydrogel-coated catheter on the occurrence of catheter-associated urinary tract infection. This was a 1-year prospective study conducted at a single centre in Hong Kong. Adult patients with an indwelling urinary catheter for longer than 24 hours were recruited. The incidence of catheter-associated urinary tract infection in patients with a conventional latex Foley catheter without hydrogel was compared with that in patients with a silver alloy and hydrogel-coated catheter. The most recent definition of urinary tract infection was based on the latest surveillance definition of the National Healthcare Safety Network managed by Centers for Disease Control and Prevention. A total of 306 patients were recruited with a similar ratio between males and females. The mean (standard deviation) age was 81.1 (10.5) years. The total numbers of catheter-days were 4352 and 7474 in the silver-coated and conventional groups, respectively. The incidences of catheter-associated urinary tract infection per 1000 catheter-days were 6.4 and 9.4, respectively (P=0.095). There was a 31% reduction in the incidence of catheter-associated urinary tract infection per 1000 catheter-days in the silver-coated group. Escherichia coli was the most commonly involved pathogen (36.7%) of all cases. Subgroup analysis revealed that the protective effect of silver-coated catheter was more pronounced in long-term users as well as female patients with a respective 48% (P=0.027) and 42% (P=0.108) reduction in incidence of catheter-associated urinary tract infection. The mean catheterisation time per person was the longest in patients using a silver-coated catheter (17.0 days) compared with those using a conventional (10.8 days) or both types of catheter (13.6 days) [P=0.01]. Silver alloy and hydrogel-coated catheters appear to be effective in preventing catheter

  12. [Suprapubic urinary diversion using Cystofix--an alternative to the urethral indwelling catheter].

    PubMed

    Müller, J; Sulmoni, M

    1992-01-01

    Suprapubic Cystofix-cystostomy is a valuable alternative to the Foley-catheter. The advantages of suprapubic cystostomy are mainly a reduction of urinary tract infections, inflammatory reactions in the lower urinary tract and avoidance of late urethral strictures after transurethral catheterism. There are a few contraindications to be considered, mainly an empty bladder and coagulation disorders. The complication rate of suprapubic Cystofix-cystostomy, usually gross haematuria, is very low. Cystofix-cystostomy is as useful for short term urinary drainage as for long term drainage in the case of chronic voiding disorders.

  13. Balloon dilation of the cartilaginous portion of the eustachian tube: initial safety and feasibility analysis in a cadaver model.

    PubMed

    Poe, Dennis S; Hanna, Bassem Matta Nashed

    2011-01-01

    Balloon catheter dilation of diseased sinus ostia has recently demonstrated efficacy and safety in the treatment of chronic sinus disease with 2 years of follow-up. Similar to sinus surgery, initial studies of partial resection of inflamed mucosa from within the cartilaginous eustachian tube (ET) have demonstrated efficacy and safety in the treatment of medically refractory otitis media with effusion. Therefore, balloon dilation of the cartilaginous ET was investigated as a possible treatment modality for otitis media. A protocol for sinus balloon catheter dilation was evaluated in each of the cartilaginous ETs in 8 fresh human cadaver heads. Computed tomographic scans and detailed endoscopic inspections with video or photographic documentation were performed pre- and posttreatment, and gross anatomical dissections were done to analyze the effects of treatment and to look for evidence of undesired injury. Catheters successfully dilated all cartilaginous ETs without any significant injuries. There were no bony or cartilaginous fractures, and 3 specimens showed minor mucosal tears in the anterolateral or inferior walls. Volumetric measurements of the cartilaginous ET lumens showed a change from an average of 0.16 to 0.49 cm(3) (SD, 0.12), representing an average increase of 357% (range, 20-965%). Balloon catheter dilation of the nasopharyngeal orifice of the ET was shown to be feasible and without evidence of untoward injury. A significant increase in volume of the cartilaginous ET was achieved. A clinical study is now indicated to determine whether balloon dilation will demonstrate lasting benefits and safety in the treatment of otitis media. Copyright © 2011 Elsevier Inc. All rights reserved.

  14. Emergency coronary angioplasty with stenting using Cordis® diagnostic coronary catheters when there is difficulty in engaging guide catheters and bench evaluation of diagnostic and guide catheters.

    PubMed

    Arokiaraj, Mark Christopher

    2018-02-01

    Difficulty in engaging with guide catheters is not uncommon in acute emergencies. We aimed to evaluate the use of Cordis ® INFINITI diagnostic catheters to perform angioplasty in patients in whom the coronaries cannot be engaged using standard guide catheters. In 34 cases of acute coronary syndrome, when difficulty in engagement with two standard guide catheters was encountered with reasonable manipulations, angioplasty was performed using diagnostic catheters. In total, 40 stents were placed by this technique. Pushability and trackability, distal tip flexion and three-point bending tests were performed to evaluate the performance of the guide and diagnostic catheters. Angioplasty was performed easily in a setting where it would have been very difficult to perform. Coronary dissection occurred in one patient, treated by a stent. The stent and dilatation balloons were easily passed through the diagnostic catheters. Pressure tracings were clearly preserved with certain stent delivery systems, and at angioplasty, although there was slightly reduced opacification of the respective artery, the coronary anatomy was sufficiently visualized to perform angioplasty. No periprocedural target lesion complications were seen in any cases. Pushability and trackability tests showed good force transmission along a tortuous path with diagnostic catheters, and balanced force-displacement curves from three-point bending tests and distal tip softness tests. Angioplasty with stenting can be performed safely through 6F Cordis ® infiniti diagnostic catheters when difficulty in engaging guide catheters is encountered. Copyright © 2018 Sociedade Portuguesa de Cardiologia. Publicado por Elsevier España, S.L.U. All rights reserved.

  15. Evaluation of intra-operative tramadol for prevention of catheter-related bladder discomfort: a prospective, randomized, double-blind study.

    PubMed

    Agarwal, A; Yadav, G; Gupta, D; Singh, P K; Singh, U

    2008-10-01

    Catheter-related bladder discomfort (CRBD) is defined as an urge to void or discomfort in the supra-pubic region; reported postoperatively in patients who have had urinary catheterization intra-operatively. We have evaluated tramadol, a centrally acting opioid analgesic with muscarinic receptor antagonist properties for prevention of CRBD. Fifty-four adults (18-60 yr), ASA physical status I and II of either sex, undergoing elective percutaneous nephro-lithomy were randomly divided into two groups of 27 each. Control (C) group received normal saline (NS; 2 ml), whereas Tramadol (T) group received tramadol 1.5 mg kg(-1). All medications were diluted in 2 ml NS and administered 30 min before extubation. Intra-operatively, urinary catherization was performed with a 16 Fr Foley's catheter, and the balloon was inflated with 10 ml distilled water. The CRBD was assessed at 0, 1, 2, and 6 h after patient's arrival in the post-anaesthesia care unit along with total postoperative fentanyl requirement. Severity of CRBD was graded as none, mild, moderate and severe. Data were analysed by one-way ANOVA, Z-test, and Fisher's exact test. P<0.05 was considered significant. Incidence and severity of CRBD was reduced in T group compared with C group at all time points (P<0.05). Postoperative pain as assessed by visual analogue scale and total postoperative fentanyl requirement (microg kg(-1)) was also reduced in the T group [176 (SD 26.5)] compared with C group [210 (34.6)] (P<0.05). Tramadol 1.5 mg kg(-1) administered i.v. 30 min before extubation decreases the incidence and severity of CRBD and postoperative fentanyl requirement.

  16. Laparoscopic hernia repair and bladder injury.

    PubMed

    Dalessandri, K M; Bhoyrul, S; Mulvihill, S J

    2001-01-01

    Bladder injury is a complication of laparoscopic surgery with a reported incidence in the general surgery literature of 0.5% and in the gynecology literature of 2%. We describe how to recognize and treat the injury and how to avoid the problem. We report two cases of bladder injury repaired with a General Surgical Interventions (GSI) trocar and a balloon device used for laparoscopic extraperitoneal inguinal hernia repair. One patient had a prior appendectomy; the other had a prior midline incision from a suprapubic prostatectomy. We repaired the bladder injury, and the patients made a good recovery. When using the obturator and balloon device, it is important to stay anterior to the preperitoneal space and bladder. Prior lower abdominal surgery can be considered a relative contraindication to extraperitoneal laparoscopic hernia repair. Signs of gas in the Foley bag or hematuria should alert the surgeon to a bladder injury. A one- or two-layer repair of the bladder injury can be performed either laparoscopically or openly and is recommended for a visible injury. Mesh repair of the hernia can be completed provided no evidence exists of urinary tract infection. A Foley catheter is placed until healing occurs.

  17. Evaluation of hypopharyngeal suction to eliminate aspiration: the Retro-Esophageal Suction (REScue) catheter.

    PubMed

    Belafsky, Peter C; Mehdizadeh, O B; Ledgerwood, L; Kuhn, M

    2015-02-01

    Profound oropharyngeal dysphagia (OPD) is common and costly. Treatment options are limited. The purpose of this investigation was to evaluate the utility of hypopharyngeal suction at the upper esophageal sphincter (UES) to eliminate aspiration. Five different catheters were passed retrograde up the esophagus and positioned at the UES in a cadaver model of profound OPD. Suction was affixed to each catheter. 10 cc of barium was administered into the pyriform sinus, and videofluoroscopy was utilized to evaluate the presence of aspiration. 6 trials were administered per catheter and for a no catheter control. The outcome measures were the incidence of aspiration, the NIH Swallow Safety Scale (NIH-SSS), and UES opening. Control trials with no suction resulted in an aspiration rate of 100 % (6/6 trials). Negative pressure through 16, 18, 24, and 30 Fr catheter resulted in an aspiration rate of 0 % (0/24 trials; p < 0.001), and suction through a 12-Fr catheter resulted in an aspiration rate of 33 % (2/6 trials; p > 0.05). The mean NIH-SSS improved from 7.0 (±0.0) in the control to 0 (±0.0) with hypopharyngeal suction (18 Fr nasogastric catheter; p < 0.001). Mean UES opening improved from 0.0 (±0.0) mm in the control condition to 8.6 (±0.2) mm with a hypopharyngeal catheter (16 Fr Foley catheter; p < 0.001). Negative pressure applied through retro-esophageal suction catheters (>12 Fr) at the level of the UES reduced aspiration by 100 % and significantly increased UES opening in a cadaveric model of profound oropharyngeal dysphagia.

  18. Balloon dilation of the eustachian tube for dilatory dysfunction: A randomized controlled trial.

    PubMed

    Poe, Dennis; Anand, Vijay; Dean, Marc; Roberts, William H; Stolovitzky, Jose Pablo; Hoffmann, Karen; Nachlas, Nathan E; Light, Joshua P; Widick, Mark H; Sugrue, John P; Elliott, C Layton; Rosenberg, Seth I; Guillory, Paul; Brown, Neil; Syms, Charles A; Hilton, Christopher W; McElveen, John T; Singh, Ameet; Weiss, Raymond L; Arriaga, Moises A; Leopold, John P

    2018-05-01

    To assess balloon dilation of the Eustachian tube with Eustachian tube balloon catheter in conjunction with medical management as treatment for Eustachian tube dilatory dysfunction. In this prospective, multicenter, randomized, controlled trial, we assigned, in a 2:1 ratio, patients age 22 years and older with Eustachian tube dilatory dysfunction refractory to medical therapy to undergo balloon dilation of the Eustachian tube with balloon catheter in conjunction with medical management or medical management alone. The primary endpoint was normalization of tympanogram at 6 weeks. Additional endpoints were normalization of Eustachian Tube Dysfunction Questionaire-7 symptom scores, positive Valsalva maneuver, mucosal inflammation, and safety. Primary efficacy results demonstrated superiority of balloon dilation of the Eustachian tube with balloon catheter + medical management compared to medical management alone. Tympanogram normalization at 6-week follow-up was observed in 51.8% (72/139) of investigational patients versus 13.9% (10/72) of controls (P < .0001). Tympanogram normalization in the treatment group was 62.2% after 24 weeks. Normalization of Eustachian Tube Dysfunction Questionaire-7 Symptom scores at 6-week follow-up was observed in 56.2% (77/137) of investigational patients versus 8.5% (6/71) controls (P < .001). The investigational group also demonstrated substantial improvement in both mucosal inflammation and Valsalva maneuver at 6-week follow-up compared to controls. No device- or procedure-related serious adverse events were reported for those who underwent balloon dilation of the Eustachian tube. This study demonstrated superiority of balloon dilation of the Eustachian tube with balloon catheter + medical management compared to medical management alone to treat Eustachian tube dilatory dysfunction in adults. 1b. Laryngoscope, 128:1200-1206, 2018. © 2017 The American Laryngological, Rhinological and Otological Society, Inc.

  19. Bladder Management

    MedlinePlus

    ... Catheterization • Urinary Tract Infections: Indwelling (Foley) Catheter Bladder Management [ Download this pamphlet: "Bladder Management" - (PDF, 499KB) ] The ... and medication or surgery may be helpful. Bladder Management Foley or Suprapubic Catheter A tube is inserted ...

  20. Thrombus aspiration catheter is a Dottering balloon.

    PubMed

    Sheshagiri Rao, D; Barik, Ramachandra; Prasad, Akula Siva

    2016-01-01

    Coronary angiogram in a young man with history of STEMI with delayed presentation revealed subtotal occlusion of left anterior descending artery (LAD) with large thrombotic filling defect distal to the critical lesion. PCI was preferred without delay because of ongoing chest pain. Several runs of thrombus aspiration failed to detect any visible thrombus. However, the immediate angiogram after thrombus aspiration showed complete distal embolization of the thrombus which could have been achieved by Dottering or balloon dilatation. In contrary to the general perception, does thrombus aspiration push more thrombus than it can aspirate? Copyright © 2016 Cardiological Society of India. Published by Elsevier B.V. All rights reserved.

  1. 77 FR 63308 - J. William Foley Incorporated v. United Illuminating Company; Notice of Complaint

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-10-16

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. EL12-106-000] J. William Foley Incorporated v. United Illuminating Company; Notice of Complaint Take notice that on October 5...) and 825(e), J. William Foley Incorporated (Complainant) filed a formal complaint against United...

  2. Early catheter removal after radical retropubic prostatectomy: long-term followup.

    PubMed

    Koch, Michael O; Nayee, Anish H; Sloan, James; Gardner, Thomas; Wahle, Greg R; Bihrle, Richard; Foster, Richard S

    2003-06-01

    We examine the complication and continence rates with early catheter removal (day 3 or 4) after radical retropubic prostatectomy. A total of 365 patients with localized prostate cancer underwent radical retropubic prostatectomy at Indiana University Hospital with planned urethral catheter removal before discharge home. Low pressure cystograms were performed on postoperative day 3 or 4 to determine if catheter removal was possible. A subset of patients were analyzed using a validated prostate cancer specific questionnaire (University of California, Los Angeles Prostate Cancer Symptom Index) to determine quality of life outcomes. The catheter was removed on postoperative day 3 or 4 in 263 patients (72%). The reasons for leaving the catheter indwelling were significant leak on cystogram or excessive suprapubic drainage (21%), extensive bladder neck reconstruction (1%) and prolonged hospitalization because of an ileus or other complicating factor (6%). Thirteen patients (3.6%) were either unable to void after catheter removal or presented with retention (not associated with hematuria or clots) after hospital discharge, requiring reinsertion of the Foley catheter. A total of 41 patients (11%) had either an early or late complication (excluding incontinence). There were 3 complications (0.8%) that were considered major because they were potentially life threatening or required a return to the operating room. A pelvic abscess developed in 2 patients and a lymphocele in 1, which required percutaneous drainage. After at least 6 months (mean 20.9 months) 140 patients (89.2%) and 14 (8.9%) reported excellent and good continence, respectively. The patient questionnaire demonstrated bother scores to be minimal to no bother for 95% to 98% of patients at 6 and 12 months. This study confirms that it is safe to remove catheters in most patients 3 to 4 days after prostatectomy if a cystogram demonstrates no extravasation. Complication rates and continence rates with this approach

  3. An Endovascular Approach to the Entrapped Central Venous Catheter After Cardiac Surgery

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Desai, Shamit S., E-mail: shamit.desai@northwestern.edu; Konanur, Meghana; Foltz, Gretchen

    PurposeEntrapment of central venous catheters (CVC) at the superior vena cava (SVC) cardiopulmonary bypass cannulation site by closing purse-string sutures is a rare complication of cardiac surgery. Historically, resternotomy has been required for suture release. An endovascular catheter release approach was developed.Materials and MethodsFour cases of CVC tethering against the SVC wall and associated resistance to removal, suggestive of entrapment, were encountered. In each case, catheter removal was achieved using a reverse catheter fluoroscopically guided over the suture fixation point between catheter and SVC wall, followed by the placement of a guidewire through the catheter. The guidewire was snared andmore » externalized to create a through-and-through access with the apex of the loop around the suture. A snare placed from the femoral venous access provided concurrent downward traction on the distal CVC during suture release maneuvers.ResultsIn the initial attempt, gentle traction freed the CVC, which fractured and was removed in two sections. In the subsequent three cases, traction alone did not release the CVC. Therefore, a cutting balloon was introduced over the guidewire and inflated. Gentle back-and-forth motion of the cutting balloon atherotomes successfully incised the suture in all three attempts. No significant postprocedural complications were encountered. During all cases, a cardiovascular surgeon was present in the interventional suite and prepared for emergent resternotomy, if necessary.ConclusionAn endovascular algorithm to the “entrapped CVC” is proposed, which likely reduces risks posed by resternotomy to cardiac surgery patients in the post-operative period.« less

  4. Transarterial Balloon-assisted Onyx Embolization of Intracranial Arteriovenous Malformations Using a Dual-lumen Balloon Microcatheter: Two Case Reports.

    PubMed

    Kim, Sang Heum; Kim, Tae Gon; Kong, Min Ho

    2017-09-01

    The Onyx system has been well established in recent years as a very important material in the treatment of arteriovenous malformations (AVMs). When using the Onyx, it is essential to wait for the creation of a plug around the tip of the catheter, which enables the effective forward penetration of Onyx. Recent reports have shown that the introduction of a dimethyl sulfoxide compatible dual-lumen balloon microcatheter improves the efficiency of AVM embolization. We report our recent experience of two cases of intracranial AVM embolization using Onyx and the transarterial balloon-assisted technique. In both cases, the procedures were successfully performed and the nidus of the AVM was totally occluded in a relatively short time. This technique may enable immediate forward flow and penetration of Onyx without concern about reflux. It may also reduce the procedure time and increase the angiographic occlusion rate. Navigation of the dual-lumen balloon microcatheter nevertheless remains a challenge.

  5. Transarterial Balloon-assisted Onyx Embolization of Intracranial Arteriovenous Malformations Using a Dual-lumen Balloon Microcatheter: Two Case Reports

    PubMed Central

    Kim, Sang Heum; Kong, Min Ho

    2017-01-01

    The Onyx system has been well established in recent years as a very important material in the treatment of arteriovenous malformations (AVMs). When using the Onyx, it is essential to wait for the creation of a plug around the tip of the catheter, which enables the effective forward penetration of Onyx. Recent reports have shown that the introduction of a dimethyl sulfoxide compatible dual-lumen balloon microcatheter improves the efficiency of AVM embolization. We report our recent experience of two cases of intracranial AVM embolization using Onyx and the transarterial balloon-assisted technique. In both cases, the procedures were successfully performed and the nidus of the AVM was totally occluded in a relatively short time. This technique may enable immediate forward flow and penetration of Onyx without concern about reflux. It may also reduce the procedure time and increase the angiographic occlusion rate. Navigation of the dual-lumen balloon microcatheter nevertheless remains a challenge. PMID:29159158

  6. PTA of supra-aortic arteries with temporary balloon occlusion to avoid distal embolism.

    PubMed

    Koike, T; Minakawa, T; Abe, H; Takeuchi, S; Sasaki, O; Nishimaki, K; Tanaka, R

    1992-03-01

    Percutaneous transluminal angioplasty (PTA) was carried out in eight patients with cervical arterial stenosis; six in the subclavian and brachiocephalic arteries (5 with subclavian steal syndrome), one in the common carotid artery, and one in both the brachiocephalic and common carotid arteries (with subclavian steal syndrome). The PTA balloon catheters were introduced via the femoral artery in seven and brachial artery in one. To prevent distal embolization through the vertebral and internal carotid arteries, the blood flow in these vessels was temporarily occluded with a balloon catheter. The dilation of the stenotic areas was generally satisfactory. Antegrade blood flow was promptly obtained in the vertebral artery even in patients with subclavian steal syndrome. In all patients, the clinical symptoms improved. Two patients underwent repeat PTA because of restenosis.

  7. [Interventional catheter treatment of bypass graft stenosis: comparison of intracoronary stent implantation and balloon angioplasty].

    PubMed

    Heidland, U E; Heintzen, M P; Schoppmann, D; Michel, C J; Strauer, B E

    2000-02-25

    Balloon angioplasty of a stenosed bypass graft has a much higher risk of recurrent stenosis than dilatation of a stenosed native coronary artery. Intracoronary stent implantation has established itself as the better treatment of native coronary artery stenosis than conventional balloon angioplasty. However, there is still uncertainty whether intracoronary stent implantation in stenosed bypass vessels gives better long-term results than conventional balloon angioplasty. Results were retrospectively analyzed of unrandomized 224 primarily successful interventions--122 balloon dilatations and 102 stent implantations--performed between January 1996 and June 1998 on stenosed coronary bypass grafts, re-examined by coronary angiography an average of 6 months later. All but 11 patients were on combined aspirin and ticlopidine antiplatelet aggregation treatment. There was a significantly lower 6-month restenosis rate (30.4%) after stent implantation than after balloon dilatation (51.6%). The re-intervention rate was also significantly lower after stent implantation. These data suggest that stent implantation of stenosed coronary bypass grafts under cover of platelet-aggregation inhibition with aspirin and ticlopidine provides a lower restenosis and thus higher revascularization rate than conventional balloon dilatation.

  8. Cross-sectional Analysis of the Relationship between Paranasal Sinus Balloon Catheter Dilations and Industry Payments among Otolaryngologists.

    PubMed

    Fujiwara, Rance J T; Shih, Allen F; Mehra, Saral

    2017-11-01

    Objective To characterize the relationship between industry payments and use of paranasal sinus balloon catheter dilations (BCDs) for chronic rhinosinusitis. Study Design Cross-sectional analysis of Medicare B Public Use Files and Open Payments data. Setting Two national databases, 2013 to 2014. Subjects and Methods Physicians with Medicare claims with Current Procedural Terminology codes 31295 to 31297 were identified and cross-referenced with industry payments. Multivariate linear regression controlling for age, race, sex, and comorbidity in a physician's Medicare population was performed to identify associations between use of BCDs and industry payments. The final analysis included 334 physicians performing 31,506 procedures, each of whom performed at least 11 balloon dilation procedures. Results Of 334 physicians, 280 (83.8%) received 4392 industry payments in total. Wide variation in payments to physicians was noted (range, $43.29-$111,685.10). The median payment for food and beverage was $19.26 and that for speaker or consulting fees was $409.45. One payment was associated with an additional 3.05 BCDs (confidence interval [95% CI],1.65-4.45; P < .001). One payment for food and beverages was associated with 3.81 additional BCDs (95% CI, 2.13-5.49; P < .001), and 1 payment for speaker or consulting fees was associated with 5.49 additional BCDs (95% CI, 0.32-10.63; P = .04). Conclusion Payments by manufacturers of BCD devices were associated with increased use of BCD for chronic rhinosinusitis. On separate analyses, the number of payments for food and beverages as well as that for speaker and consulting fees was associated with increased BCD use. This study was cross-sectional and cannot prove causality, and several factors likely exist for the uptrend in BCD use.

  9. Long-term outcome of 154 patients receiving balloon-occluded retrograde transvenous obliteration for gastric fundal varices.

    PubMed

    Imai, Yukinori; Nakazawa, Manabu; Ando, Satsuki; Sugawara, Kayoko; Mochida, Satoshi

    2016-11-01

    This study aims to clarify the long-term outcome of therapeutic strategies including balloon-occluded retrograde transvenous obliteration (B-RTO) for patients with gastric fundal varices. The subjects were 154 patients with gastric fundal varices fulfilling the criteria for receiving B-RTO. In patients showing variceal bleeding, endoscopic therapies and/or balloon tamponade was performed to achieve hemostasis. B-RTO was accomplished with injection of 5% ethanolamine oleate through a standard balloon catheter except for patients with atypical varices, in whom a microballoon catheter was used to occlude drainage vessels other than a gastrorenal shunt. In patients complicated with esophageal varices at baseline, endoscopic therapies were performed following B-RTO. Balloon-occluded retrograde transvenous obliteration was performed successfully in 147 patients (95%), including 15 patients using a microballoon catheter. Complete variceal obliteration was achieved in all patients. Additional endoscopic therapies for esophageal varices were performed in 31 patients. Gastric varices did not recur in any of these patients. The cumulative survival rates at 1, 3, and 5 years after B-RTO were 91%, 76%, and 72%, respectively. Child-Pugh scores and hepatocellular carcinoma complication were identified as prognostic factors associated with survival rates. The cumulative exacerbation rates of esophageal varices at 1, 3, and 5 years were 13%, 20%, and 27%, respectively, and rupture developed in six patients, which were successfully treated with endoscopic therapies. Therapeutic strategies including B-RTO with a microballoon catheter were useful to achieve a favorable outcome in patients with gastric fundal varices especially in those manifesting Child-Pugh class-A liver damage and/or those without hepatocellular carcinoma complication. © 2016 Journal of Gastroenterology and Hepatology Foundation and John Wiley & Sons Australia, Ltd.

  10. Balloon-Occluded Carbon Dioxide Gas Angiography for Internal Iliac Arteriography and Intervention.

    PubMed

    Kishino, Mitsuhiro; Nakaminato, Shuichiro; Kitazume, Yoshio; Miyasaka, Naoyuki; Kudo, Toshifumi; Saida, Yukihisa; Tateishi, Ukihide

    2018-07-01

    The usefulness of carbon dioxide (CO 2 ) gas digital subtraction angiography (DSA) has been reported for patients with renal insufficiency and allergy to iodinated contrast agents. However, CO 2 gas cannot replace the iodinated contrast agent in all cases owing to some disadvantages. We describe balloon-occluded CO 2 DSA (B-CO 2 DSA) as an improved CO 2 DSA procedure for interventions in the internal iliac artery (IIA) region and compare the quality of images obtained using conventional CO 2 DSA and B-CO 2 DSA. B-CO 2 DSA-guided embolization was performed for one case of genital bleeding with an acute anaphylactic reaction to the iodinated contrast agent and for three cases of type II endoleaks after endovascular abdominal aortic aneurysm repair with renal dysfunction. A 9-mm occlusion balloon catheter was placed just after the orifice of the IIA. Then, 10-15 ml of CO 2 gas was injected manually via the catheter with and without balloon occlusion. The quality of sequential digital subtraction angiograms was analyzed based on a scoring criterion. In all four cases, image quality was improved with B-CO 2 DSA; the poor quality of images without balloon occlusion was because of reflux of the CO 2 gas. B-CO 2 DSA improves the image quality of CO 2 DSA in the IIA region and is useful for vascular intervention. Level IV.

  11. Deep intubation of 8 Fr guiding catheter to deliver coronary stent graft to seal coronary perforation: a case report.

    PubMed

    Salwan, R; Mathur, A; Jhamb, D K; Seth, A

    2001-09-01

    Coronary perforation is an uncommon complication of angioplasty and is a challenging situation to manage. We describe a case of complex multivessel coronary angioplasty complicated by coronary perforation following balloon rupture that was successfully managed with a coronary stent graft. Delivery of the stent graft to the site of vessel rupture required deep intubation of an 8 Fr guiding catheter over the shaft of an inflated balloon. In addition to the availability of covered stents, it is essential to be familiar with various skills necessary to deploy these stents. Cathet Cardiovasc Intervent 2001;54:59-62. Copyright 2001 Wiley-Liss, Inc.

  12. Initial Experience with Balloon-Occluded Trans-catheter Arterial Chemoembolization (B-TACE) for Hepatocellular Carcinoma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Maruyama, Mitsunari, E-mail: mitunari@med-shimane.u.ac.jp; Yoshizako, Takeshi, E-mail: yosizako@med.shimane-u.ac.jp; Nakamura, Tomonori, E-mail: t-naka@med.shimane-u.ac.jp

    2016-03-15

    PurposeThis study was performed to evaluate the accumulation of lipiodol emulsion (LE) and adverse events during our initial experience of balloon-occluded trans-catheter arterial chemoembolization (B-TACE) for hepatocellular carcinoma (HCC) compared with conventional TACE (C-TACE).MethodsB-TACE group (50 cases) was compared with C-TACE group (50 cases). The ratio of the LE concentration in the tumor to that in the surrounding embolized liver parenchyma (LE ratio) was calculated after each treatment. Adverse events were evaluated according to the Common Terminology Criteria for Adverse Effects (CTCAE) version 4.0.ResultsThe LE ratio at the level of subsegmental showed a statistically significant difference between the groups (tmore » test: P < 0.05). Only elevation of alanine aminotransferase was more frequent in the B-TACE group, showing a statistically significant difference (Mann–Whitney test: P < 0.05). While B-TACE caused severe adverse events (liver abscess and infarction) in patients with bile duct dilatation, there was no statistically significant difference in incidence between the groups. Multivariate logistic regression analysis suggested that the significant risk factor for liver abscess/infarction was bile duct dilatation (P < 0.05).ConclusionThe LE ratio at the level of subsegmental showed a statistically significant difference between the groups (t test: P < 0.05). B-TACE caused severe adverse events (liver abscess and infarction) in patients with bile duct dilatation.« less

  13. Guide Catheter Extension Device Is Effective in Renal Angioplasty for Severely Calcified Lesions.

    PubMed

    Sugimoto, Takeshi; Nomura, Tetsuya; Hori, Yusuke; Yoshioka, Kenichi; Kubota, Hiroshi; Miyawaki, Daisuke; Urata, Ryota; Kikai, Masakazu; Keira, Natsuya; Tatsumi, Tetsuya

    2017-05-23

    BACKGROUND The GuideLiner catheter extension device is a monorail-type "Child" support catheter that facilitates coaxial alignment with the guide catheter and provides an appropriate back-up force. This device has been developed in the field of coronary intervention, and now is becoming widely applied in the field of endovascular treatment. However, there has been no report on the effectiveness of the guide catheter extension device in percutaneous transluminal renal angioplasty (PTRA). CASE REPORT We encountered a case of atherosclerotic subtotal occlusion at the ostium of the left renal artery. Due to the severely calcified orifice and weaker back-up force provided by a JR4 guide catheter, we could not pass any guidewires through the target lesion. Therefore, we introduced a guide catheter extension device, the GuideLiner catheter, through the guide catheter and achieved good guidewire maneuverability. We finally deployed 2 balloon-expandable stents and successfully performed all PTRA procedures. CONCLUSIONS The guide catheter extension device can be effective in PTRA for severely calcified subtotal occlusion.

  14. Clinical efficacy, safety, and costs of percutaneous occlusive balloon catheter-assisted ureteroscopic lithotripsy for large impacted proximal ureteral calculi: a prospective, randomized study.

    PubMed

    Qi, Shiyong; Li, Yanni; Liu, Xu; Zhang, Changwen; Zhang, Hongtuan; Zhang, Zhihong; Xu, Yong

    2014-09-01

    To evaluate the clinical efficacy, safety, and costs of percutaneous occlusive balloon catheter-assisted ureteroscopic lithotripsy (POBC-URSL) for large impacted proximal ureteral calculi. 156 patients with impacted proximal ureteral stones ≥1.5 cm in size were randomized to ureteroscopic lithotripsy (URSL), POBC-URSL, and percutaneous nephrolithotomy (PNL) group between May 2010 and May 2013. For URSL, the calculi were disintegrated with the assistance of anti-retropulsion devices. POBC-URSL was performed with the assistance of an 8F percutaneous occlusive balloon catheter. PNL was finished with the combination of an ultrasonic and a pneumatic lithotripter. A flexible ureteroscope and a 200 μm laser fiber were used to achieve stone-free status to a large extent for each group. Variables studied were mean operative time, auxiliary procedure, postoperative hospital stay, operation-related complications, stone clearance rate, and treatment costs. The mean lithotripsy time for POBC-URSL was shorter than URSL, but longer than PNL (42.6±8.9 minutes vs 66.7±15.3 minutes vs 28.1±6.3 minutes, p=0.014). The auxiliary procedure rate and postoperative fever rate for POBC-URSL were significantly lower than URSL and comparable to PNL (p<0.01, p=0.034). POBC-URSL was superior to URSL with regard to the stone clearance rate at 3 days postoperatively, and as good as PNL (98.1% vs 75.0% vs 96.2%, p<0.01). The postoperative hospital stay and hematuria rate were lower in POBC-URSL group than PNL group and similar to URSL group (p=0.016, p<0.01). The treatment costs were lowest in POBC-URSL group ($1205.0±$113.9 vs $1731.7±$208.1 vs $2446.4±$166.4, p=0.004). For large impacted proximal ureteral calculi, POBC-URSL was associated with a higher stone clearance rate, fewer complications and costs. POBC-URSL combined the advantages of URSL and PNL.

  15. The Accordion Sign in the Transplant Ureter: Ramifications During Balloon Dilation of Strictures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kriegshauser, J. Scott, E-mail: skriegshauser@mayo.edu; Naidu, Sailen G.; Chang, Yu-Hui H.

    PurposeThis study was designed to demonstrate the accordion sign within the transplant ureter and evaluate its ramifications during balloon dilation of strictures.MethodsA retrospective electronic chart and imaging review included demographic characteristics, procedure reports, and complications of 28 renal transplant patients having ureteral strictures treated with percutaneous balloon dilation reported in our transplant nephrology database during an 8-year period. The accordion sign was deemed present or absent on the basis of an imaging review and was defined as present when a tortuous ureter became kinked and irregular when foreshortened after placement of a wire or a catheter. Procedure-related urine leaks weremore » categorized as occurring at the stricture if within 2 cm; otherwise, they were considered away from the stricture.ResultsThe accordion sign was associated with a significantly greater occurrence of leaks away from the stricture (P = 0.001) but not at the stricture (P = 0.34).ConclusionsThe accordion sign is an important consideration when performing balloon dilation procedures on transplant ureteral strictures, given the increased risk of leak away from the stricture. Its presence should prompt additional care during wire and catheter manipulations.« less

  16. Optimal application of the Contura multilumen balloon breast brachytherapy catheter vacuum port to deliver accelerated partial breast irradiation.

    PubMed

    Tokita, Kenneth M; Cuttino, Laurie W; Vicini, Frank A; Arthur, Douglas W; Todor, Dorin A; Julian, Thomas B; Lyden, Maureen R

    2011-01-01

    The impact of using the Contura multilumen balloon (MLB) (SenoRx, Inc., Irvine, CA) breast brachytherapy catheter's vacuum port in patients treated with accelerated partial breast irradiation (APBI) was analyzed. Data from 32 patients at two sites were reviewed. Variables analyzed included the seroma fluid (SF):air volume around the MLB before and after vacuum port use and on its ability to improve (1) the eligibility of patients for APBI and (2) dose coverage of the planning target volume for evaluation (PTV_EVAL) in eligible patients. The median SF/air volume before vacuum removal was 6.8 cc vs. 0.8 cc after vacuum removal (median reduction in SF/air volume was 90.5%). Before vacuum port use, the median SF/air volume expressed as percentage of the PTV_EVAL was 7.8% (range, 1.9-26.6) in all patients. After application of the vacuum, this was reduced to 1.2%. Before vacuum port use, 10 (31.3%) patients were not considered acceptable candidates for APBI because the SF/air volume:PTV_EVAL ratio (SF:PTV) was greater than 10% (range, 10.1-26.6%; median, 15.2%). After vacuum port use, the median SF:PTV ratio was 1.6% for a median reduction of 91.5%. In addition, the percentage of the prescribed dose covering greater than or equal to 90% of the PTV_EVAL proportionally increased a median of 8% (range, 3-10%) in eligible patients. Use of the Contura MLB vacuum port significantly improved the conformity of the target tissue to the balloon surface, leading to reproducible dose delivery and increased target volume coverage. In addition, application of the vacuum allowed the safe treatment of unacceptable patients with APBI. Copyright © 2011 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  17. GuideLiner™ as guide catheter extension for the unreachable mammary bypass graft.

    PubMed

    Vishnevsky, Alec; Savage, Michael P; Fischman, David L

    2018-03-09

    Percutaneous coronary intervention (PCI) of mammary artery bypass grafts through a trans-radial (TR) approach can present unique challenges, including coaxial vessel engagement of the guiding catheter, adequate visualization of the target lesion, sufficient backup support for equipment delivery, and the ability to reach very distal lesions. The GuideLiner catheter, a rapid exchange monorail mother-in-daughter system, facilitates successful interventions in such challenging anatomy. We present a case of a patient undergoing PCI of a right internal mammary artery (RIMA) graft via TR access in whom the graft could not be engaged with any guiding catheter. Using a balloon tracking technique over a guidewire, a GuideLiner was placed as an extension of the guiding catheter and facilitated TR-PCI by overcoming technical challenges associated with difficult anatomy. © 2018 Wiley Periodicals, Inc.

  18. Attitudes and knowledge of urethral catheters: a targeted educational intervention.

    PubMed

    Cohen, Andrew; Nottingham, Charles; Packiam, Vignesh; Jaskowiak, Nora; Gundeti, Mohan

    2016-10-01

    To assess the training of medical students and their confidence in urethral catheter placement, given growing evidence of unnecessary urology consults and iatrogenic injury. A third-year medical school class was queried about their attitudes and knowledge of catheter placement before and after the Clinical Biennium. The Clinical Biennium introduces hands-on skills prior to clinical clerkships. Urethral catheterisation is one of the skill stations that students rotate through, and urology residents provide a didactic session and supervised simulation. Confidence was self-rated regarding catheter technique, knowledge, troubleshooting, and comfort with placement in the same and opposite gender. Factual questions were posed about proper insertion and malfunctioning catheters. In all, 92 students participated in the initial survey, 41% female and 59% male, and 87% of the students had never placed a catheter. Students desired high confidence in catheter skills (4.4/5). There were no significant differences in responses for those with a desire to pursue urology vs other specialties, or procedural fields compared with non-procedural fields. Prior independent learning was reported by 38% of students and was a predictor for increased confidence across all domains (P < 0.05). In all, 16.7% of students initially identified proper male urethral insertion distance, which improved to 95.6% after the session. Student interest in urology modestly increased after the educational session (P = 0.028). At 3-6 months follow-up, students had performed a median (interquartile range) of 4 (2-7) urethral catheter placements, and 74.2% of students rated training useful or extremely useful. Indeed, 54.8% desired more instruction. Knowledge assessment indicated that 93% of students retained comprehension of proper male urethral insertion distance. Clinical Foley training rarely contradicted instruction from the Clinical Biennium (6.5%). At all time-points, medical student knowledge for

  19. Ileal Varices Treated with Balloon-Occluded Retrograde Transvenous Obliteration.

    PubMed

    Sato, Takahiro; Yamazaki, Katsu; Toyota, Jouji; Karino, Yoshiyasu; Ohmura, Takumi; Akaike, Jun

    2009-04-01

    A 55-year-old man with hepatitis B virus antigen-positive liver cirrhosis was admitted to our hospital with anal bleeding. Colonoscopy revealed blood retention in the entire colon, but no bleeding lesion was found. Computed tomography images showed that vessels in the ileum were connected to the right testicular vein, and we suspected ileal varices to be the most probable cause of bleeding. We immediately performed double balloon enteroscopy, but failed to find any site of bleeding owing to the difficulty of fiberscope insertion with sever adhesion. Using a balloon catheter during retrograde transvenous venography, we found ileal varices communicating with the right testicular vein (efferent vein) with the superior mesenteric vein branch as the afferent vein of these varices. We performed balloon occluded retrograde transvenous obliteration by way of the efferent vein of the varices and have detected no further bleeding in this patient one year after treatment.

  20. Endovascular recanalization of a port catheter-associated superior vena cava syndrome.

    PubMed

    Tonak, Julia; Fetscher, Sebastian; Barkhausen, Jörg; Goltz, Jan Peter

    2015-01-01

    Superior vena cava (SVC) syndrome owing to benign etiology is rare and endovascular techniques have been advocated as the treatment of choice. We report a case of endovascular revascularization of a port catheter-associated complete occlusion of the SVC with reversed flow in the azygos vein. In this setting using a sheath in combination with its dilatator to pass the occlusion of the SVC after neither a diagnostic catheter nor a PTA balloon would pass the lesion may be a valid option. A dual venous approach was established using the right common femoral vein and an indwelling port catheter in the right cephalic vein to dilate and stent the lesion. Finally, a port may be implanted after the revascularization had been successful. Passage through the port catheter-associated occlusion of the SVC was only possible by use of the sheath in combination with its dilatator. A dual venous access by the femoral approach and the indwelling central catheter is helpful in treating a SVC occlusion. Long-term central venous catheters may cause SVC syndrome, especially with a catheter tip located too far cranially. An endovascular revascularization of a complete occlusion of the SVC represents the therapy of choice.

  1. Percutaneous focused force aortic valvuloplasty using the buddy-catheter technique.

    PubMed

    Tada, Norio; Ootomo, Tatsushi; Meguro, Taiichiro

    2012-06-01

    Percutaneous transcatheter aortic valvuloplasty is seriously limited by high restenosis rates. We report a case where the use of a buddy-catheter technique during balloon inflation allowed increased focused force onto calcified stiff commissures with an increase in resultant valve area. This technique may result in further valve area enlargement and decrease the restenosis rate.

  2. Experimental comparison of manually inflatable versus autoinflatable retrograde cardioplegia catheters.

    PubMed

    Menasché, P

    1994-08-01

    A pig model of cardiopulmonary bypass and cardioplegic arrest was used to compare leakage around manually inflatable and autoinflatable retrograde coronary sinus cardioplegia catheters. Warm and cold blood cardioplegia were alternately delivered through the catheter under study at both low (16 to 24 mm Hg) and high (30 to 40 mm Hg) perfusion pressures. During each experiment, the coronary sinus ostium was sealed around the shaft of the retrograde cannula so that all backflow occurring during cardioplegia delivery could be collected by a separate drainage catheter inserted directly into the coronary sinus approximately midway between the right atrium and the distal end of the balloon. Only two of the 52 manually inflatable cannulas leaked. The leakage in both cases was negligible (< 1% of the total retrograde cardioplegia flow). In contrast, leakage occurred with 57 of the 73 autoinflatable devices tested (p < 0.0001) and averaged 22% +/- 3% (mean +/- the standard error of the mean) of the total retrograde flow. The temperature of the cardioplegia solution had no effect on leakage. These results suggest that autoinflatable balloons inconsistently seal the coronary sinus during cardioplegia infusion, thereby decreasing the amount of flow that effectively reaches the myocardium. This should make surgeons cautious about using them with warm blood cardioplegia, which largely relies upon the delivery of sufficiently high retrograde nutritive flows for preventing cardioprotective aerobic arrest from becoming a life-threatening ischemic arrest.

  3. Safe percutaneous suprapubic catheterisation.

    PubMed

    Goyal, N K; Goel, A; Sankhwar, S N

    2012-11-01

    We describe our technique of percutaneous suprapubic catheter insertion with special reference to steps that help to avoid common complications of haematuria and catheter misplacement. The procedure is performed using a stainless steel reusable trocar under local infiltrative anaesthesia, usually at the bedside. After clinical confirmation of a full bladder, the trocar is advanced into the bladder through a skin incision. Once the bladder is entered, the obturator is removed and the assistant inserts a Foley catheter followed by rapid balloon inflation. Slight traction is applied to the catheter for about five minutes. Patients with previous lower abdominal surgery, an inadequately distended bladder or acute pelvic trauma do not undergo suprapubic catheterisation using this method. The procedure was performed in 72 men (mean age: 42.4 years, range: 18-78 years) with urinary retention with a palpable bladder. The average duration of the procedure was less than five minutes. No complications were noted in any of the patients. Trocar suprapubic catheter insertion is a safe and effective bedside procedure for emergency bladder drainage and can be performed by resident surgeons. The common complications associated with the procedure can be avoided with a few careful steps.

  4. Guide Catheter Extension Device Is Effective in Renal Angioplasty for Severely Calcified Lesions

    PubMed Central

    Sugimoto, Takeshi; Nomura, Tetsuya; Hori, Yusuke; Yoshioka, Kenichi; Kubota, Hiroshi; Miyawaki, Daisuke; Urata, Ryota; Kikai, Masakazu; Keira, Natsuya; Tatsumi, Tetsuya

    2017-01-01

    Patient: Male, 69 Final Diagnosis: Atherosclerotic renal artery stenosis Symptoms: None Medication: — Clinical Procedure: — Specialty: Radiology Objective: Unusual setting of medical care Background: The GuideLiner catheter extension device is a monorail-type “Child” support catheter that facilitates coaxial alignment with the guide catheter and provides an appropriate back-up force. This device has been developed in the field of coronary intervention, and now is becoming widely applied in the field of endovascular treatment. However, there has been no report on the effectiveness of the guide catheter extension device in percutaneous transluminal renal angioplasty (PTRA). Case Report: We encountered a case of atherosclerotic subtotal occlusion at the ostium of the left renal artery. Due to the severely calcified orifice and weaker back-up force provided by a JR4 guide catheter, we could not pass any guide-wires through the target lesion. Therefore, we introduced a guide catheter extension device, the GuideLiner catheter, through the guide catheter and achieved good guidewire maneuverability. We finally deployed 2 balloon-expandable stents and successfully performed all PTRA procedures. Conclusions: The guide catheter extension device can be effective in PTRA for severely calcified subtotal occlusion. PMID:28533503

  5. Sheathless guide catheter in transradial percutaneous coronary intervention for ST-segment elevation myocardial infarction.

    PubMed

    Miyasaka, Masaki; Tada, Norio; Kato, Shigeaki; Kami, Masahiro; Horie, Kazunori; Honda, Taku; Takizawa, Kaname; Otomo, Tatsushi; Inoue, Naoto

    2016-05-01

    The aim of this study was to assess the safety and efficacy of sheathless guide catheters in transradial percutaneous coronary intervention (PCI) for ST-segment elevation myocardial infarction (STEMI). Transradial PCI for STEMI offers significant clinical benefits, including a reduced incidence of vascular complications. As the size of the radial artery is small, the radial artery is frequently damaged in this procedure using large-bore catheters. A sheathless guide catheter offers a solution to this problem as it does not require an introducer sheath. However, the efficacy and safety of sheathless guide catheters remain to be fully determined in emergent transradial PCI for STEMI. Data on consecutive STEMI patients undergoing primary PCI at the Sendai Kousei Hospital between September 2010 and May 2013 were analyzed. The primary endpoint was the rate of acute procedural success without access site crossover. Secondary endpoints included door-to-balloon time, fluoroscopy time, volume of contrast, and radial artery stenosis or occlusion rate. We conducted transradial PCI for 478 patients with STEMI using a sheathless guide catheter. Acute procedural success was achieved in 466 patients (97.5%). The median door-to-balloon time was 45 min (range, 15-317 min). The median fluoroscopy time was 16.4 min (range, 10-90 min). The median volume of contrast was 134 mL (range, 31-431 mL). Radial stenosis or occlusion developed in 14 (3.8%) of the 370 evaluable patients. This study showed that use of a sheathless guide catheter taking a transradial approach was effective and safe in primary PCI for STEMI. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.

  6. Peripheral Applications of Drug-Coated Balloons: Past, Present and Future

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Krokidis, Miltiadis, E-mail: mkrokidis@hotmail.com; Spiliopoulos, Stavros, E-mail: stavspiliop@upatras.gr; Katsanos, Konstantinos, E-mail: katsanos@med.upatras.gr

    2013-04-15

    Drug-coated balloon (DCB) technologies represent the latest and hottest development in the field of endovascular treatment of peripheral arterial disease. Initial experience with paclitaxel-coated balloon use in the femoral artery has demonstrated lower mid-term restenosis and superior mid-term clinical outcomes in terms of improved wound healing and reduced repeat angioplasty rates compared with standard balloon angioplasty. Many companies are presently developing and/or improving DCB catheters and therefore ongoing, technical improvements of the already existing platforms, new drugs, and innovative carriers are expected. The ongoing basic research studies and various multicenter randomized, controlled trials that are currently in progress will offermore » valuable scientific insights regarding the long-term effectiveness and other crucial issues, such as efficacy in various vascular beds, optimal balloon dosage, and post angioplasty antiplatelet therapy. Future applications of these devices also could include in-stent restenosis, anastomotic stenosis of surgical bypass, and benign stenoses of the central venous system. The authors envision that DCB angioplasty will evolve to a major paradigm shift in the endovascular treatment of occlusive vascular diseases.« less

  7. Ileal Varices Treated with Balloon-Occluded Retrograde Transvenous Obliteration

    PubMed Central

    Sato, Takahiro; Yamazaki, Katsu; Toyota, Jouji; Karino, Yoshiyasu; Ohmura, Takumi; Akaike, Jun

    2009-01-01

    A 55-year-old man with hepatitis B virus antigen-positive liver cirrhosis was admitted to our hospital with anal bleeding. Colonoscopy revealed blood retention in the entire colon, but no bleeding lesion was found. Computed tomography images showed that vessels in the ileum were connected to the right testicular vein, and we suspected ileal varices to be the most probable cause of bleeding. We immediately performed double balloon enteroscopy, but failed to find any site of bleeding owing to the difficulty of fiberscope insertion with sever adhesion. Using a balloon catheter during retrograde transvenous venography, we found ileal varices communicating with the right testicular vein (efferent vein) with the superior mesenteric vein branch as the afferent vein of these varices. We performed balloon occluded retrograde transvenous obliteration by way of the efferent vein of the varices and have detected no further bleeding in this patient one year after treatment. PMID:27956966

  8. Prophylactic Hypogastric Artery Ballooning in a Patient with Complete Placenta Previa and Increta

    PubMed Central

    Yi, Kyong Wook; Seo, Tae-Seok; So, Kyeong A; Paek, Yu Chin; Kim, Hai-Joong

    2010-01-01

    Abnormal attachment of the placenta (Placenta accreta, increta, and percreta) is an uncommon but potentially lethal cause of maternal mortality from massive postpartum hemorrhage. A 33-yr-old woman, who had been diagnosed with a placenta previa, was referred at 30 weeks gestation. On ultrasound, a complete type of placenta previa and multiple intraplacental lacunae, suggestive of placenta accreta, were noted. For further evaluation of the placenta, pelvis MRI was performed and revealed findings suspicious of a placenta increta. An elective cesarean delivery and subsequent hysterectomy were planned for the patient at 38 weeks gestation. On the day of delivery, endovascular catheters for balloon occlusion were placed within the hypogastric arteries, prior to the cesarean section. In the operating room, immediately after the delivery of the baby, bilateral hypogastric arteries were occluded by inflation of the balloons in the catheters previously placed within. With the placenta retained within the uterus, a total hysterectomy was performed in the usual fashion. The occluding balloons were deflated after closure of the vaginal cuff with hemostasis. The patient had stable vital signs and normal laboratory findings during the recovery period; she was discharged six days after delivery without complications. The final pathology confirmed a placenta increta. PMID:20358016

  9. Evaluation of balloon withdrawal forces with bare-metal stents, compared with Taxus and Cypher drug-eluting coronary stents: balloon, stent and polymer interactions.

    PubMed

    Turk, Marvee; Gupta, Vishal; Fischell, Tim A

    2010-03-01

    There have been reports of serious complications related to difficulty removing the deflated Taxus stent delivery balloon after stent deployment. The purpose of this study was to determine whether the Taxus SIBS polymer was "sticky" and associated with an increase in the force required to remove the stent delivery balloon after stent deployment, using a quantitative, ex-vivo model. Balloon-polymer-stent interactions during balloon withdrawal were measured with the Taxus Liberté, Liberté bare-metal stent (BMS; no polymer = control), the Cordis Cypher drug-eluting stent (DES; PEVA/PBMA polymer) and the BX Velocity (no polymer). We quantitatively measured the force required to remove the deflated stent delivery balloon from each of these stents in simulated vessels at 37 degrees C in a water bath. Balloon withdrawal forces were measured in straight (0 degree curve), mildly curved (20 degree curve) and moderately curved (40 degree curve) simulated vessel segments. The average peak force required to remove the deflated balloon catheter from the Taxus Liberté DES, the Liberté BMS, the Cypher DES, and the Bx Velocity BMS were similar in straight segments, but were much greater for the Taxus Liberté in the moderately curved segments (1.4 lbs vs. 0.11 lbs, 0.11 lbs and 0.12 lbs, respectively; p < 0.0001). The SIBS polymer of the Taxus Liberté DES appears to be "sticky" and is associated with high forces required to withdraw the deflated balloon from the deployed stent in curved segments. This withdrawal issue may help to explain the clinical complications that have been reported with this device.

  10. A new idea for a safer approach to the supra-aortic trunks: the Piton™ catheter.

    PubMed

    Setacci, C; Moratto, R; Sirignano, P; Setacci, F; Silingardi, R; Coppi, G

    2011-04-01

    Carotid artery disease is among the most common causes of stroke, and stroke is the third leading cause of death in industrialized countries. Thus the personal health and socioeconomic burden of carotid artery disease is significant. Carotid artery disease accounts for approximately 5-12% of new strokes in patients amenable to revascularization therapy. Atherosclerosis is the main reason for stroke and accounts for approximately one third of all cases. Carotid stenting is nowadays considered a valid standard alternative to surgical carotid endarterectomy, especially in patients having a high perioperative risk. The first carotid balloon angioplasty was carried out in 1979 and the first carotid balloon-expandable bare metal stents were implanted 10 years later, in 1989. However, carotid stenting at that time was associated with major complications, due to extrinsic compression and subsequent to the steel stents used. The Piton™ GC (carotid guide catheter) is intended to facilitate the introduction and placement of interventional devices (e.g., guidewires, stent delivery systems, dilation balloons, angiographic- or micro-catheters, etc.) into the human vasculature to treat vascular obstructive disease, including but not limited to the supra-aortic vessels.

  11. Intracavitary moderator balloon combined with (252)Cf brachytherapy and boron neutron capture therapy, improving dosimetry in brain tumour and infiltrations.

    PubMed

    Brandão, S F; Campos, T P R

    2015-07-01

    This article proposes a combination of californium-252 ((252)Cf) brachytherapy, boron neutron capture therapy (BNCT) and an intracavitary moderator balloon catheter applied to brain tumour and infiltrations. Dosimetric evaluations were performed on three protocol set-ups: (252)Cf brachytherapy combined with BNCT (Cf-BNCT); Cf-BNCT with a balloon catheter filled with light water (LWB) and the same set-up with heavy water (HWB). Cf-BNCT-HWB has presented dosimetric advantages to Cf-BNCT-LWB and Cf-BNCT in infiltrations at 2.0-5.0 cm from the balloon surface. However, Cf-BNCT-LWB has shown superior dosimetry up to 2.0 cm from the balloon surface. Cf-BNCT-HWB and Cf-BNCT-LWB protocols provide a selective dose distribution for brain tumour and infiltrations, mainly further from the (252)Cf source, sparing the normal brain tissue. Malignant brain tumours grow rapidly and often spread to adjacent brain tissues, leading to death. Improvements in brain radiation protocols have been continuously achieved; however, brain tumour recurrence is observed in most cases. Cf-BNCT-LWB and Cf-BNCT-HWB represent new modalities for selectively combating brain tumour infiltrations and metastasis.

  12. Design of a cost-effective, hemodynamically adjustable model for resuscitative endovascular balloon occlusion of the aorta (REBOA) simulation.

    PubMed

    Keller, Benjamin A; Salcedo, Edgardo S; Williams, Timothy K; Neff, Lucas P; Carden, Anthony J; Li, Yiran; Gotlib, Oren; Tran, Nam K; Galante, Joseph M

    2016-09-01

    Resuscitative endovascular balloon occlusion of the aorta (REBOA) is an adjunct technique for salvaging patients with noncompressible torso hemorrhage. Current REBOA training paradigms require large animals, virtual reality simulators, or human cadavers for acquisition of skills. These training strategies are expensive and resource intensive, which may prevent widespread dissemination of REBOA. We have developed a low-cost, near-physiologic, pulsatile REBOA simulator by connecting an anatomic vascular circuit constructed out of latex and polyvinyl chloride tubing to a commercially available pump. This pulsatile simulator is capable of generating cardiac outputs ranging from 1.7 to 6.8 L/min with corresponding arterial blood pressures of 54 to 226/14 to 121 mmHg. The simulator accommodates a 12 French introducer sheath and a CODA balloon catheter. Upon balloon inflation, the arterial waveform distal to the occlusion flattens, distal pulsation within the simulator is lost, and systolic blood pressures proximal to the balloon catheter increase by up to 62 mmHg. Further development and validation of this simulator will allow for refinement, reduction, and replacement of large animal models, costly virtual reality simulators, and perfused cadavers for training purposes. This will ultimately facilitate the low-cost, high-fidelity REBOA simulation needed for the widespread dissemination of this life-saving technique.

  13. High definition urethral pressure profilometry: Evaluating a novel microtip catheter.

    PubMed

    Klünder, Mario; Amend, Bastian; Vaegler, Martin; Kelp, Alexandra; Feuer, Ronny; Sievert, Karl-Dietrich; Stenzl, Arnulf; Sawodny, Oliver; Ederer, Michael

    2016-11-01

    Urethral pressure profilometry (UPP) is used in the diagnosis of stress urinary incontinence (SUI). SUI is a significant medical, social, and economic problem, affecting about 12.5% of the population. A novel microtip catheter was developed for UPP featuring an inclination sensor and higher angular resolution compared to systems in clinical use today. Therewith, the location of each measured pressure sample can be determined and the spatial pressure distribution inside the urethra reconstructed. In order to assess the performance and plausibility of data from the microtip catheter, we compare it to data from a double balloon air charged system. Both catheters are used on sedated female minipigs. Data from the microtip catheter are processed through a signal reconstruction algorithm, plotted and compared against data from the air-charged catheter. The microtip catheter delivers results in agreement with previous comparisons of microtip and air-charged systems. It additionally provides a new level of detail in the reconstructed UPPs which may lead to new insights into the sphincter mechanism of minipigs. The ability of air-charged catheters to measure pressure circumferentially is widely considered a main advantage over microtip catheters. However, directional pressure readings can provide additional information on angular fluctuations in the urethral pressure distribution. It is shown that the novel microtip catheter in combination with a signal reconstruction algorithm delivers plausible data. It offers the opportunity to evaluate urethral structures, especially the sphincter, in context of the correct location within the anatomical location of the pelvic floor. Neurourol. Urodynam. 35:888-894, 2016. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.

  14. Antibody-Based Therapy for Enterococcal Catheter-Associated Urinary Tract Infections.

    PubMed

    Flores-Mireles, Ana L; Walker, Jennifer N; Potretzke, Aaron; Schreiber, Henry L; Pinkner, Jerome S; Bauman, Tyler M; Park, Alyssa M; Desai, Alana; Hultgren, Scott J; Caparon, Michael G

    2016-10-25

    Gram-positive bacteria in the genus Enterococcus are a frequent cause of catheter-associated urinary tract infection (CAUTI), a disease whose treatment is increasingly challenged by multiantibiotic-resistant strains. We have recently shown that E. faecalis uses the Ebp pilus, a heteropolymeric surface fiber, to bind the host protein fibrinogen as a critical step in CAUTI pathogenesis. Fibrinogen is deposited on catheters due to catheter-induced inflammation and is recognized by the N-terminal domain of EbpA (EbpA NTD ), the Ebp pilus's adhesin. In a murine model, vaccination with EbpA NTD confers significant protection against CAUTI. Here, we explored the mechanism of protection using passive transfer of immune sera to show that antisera blocking EbpA NTD -fibrinogen interactions not only is prophylactic but also can act therapeutically to reduce bacterial titers of an existing infection. Analysis of 55 clinical CAUTI, bloodstream, and gastrointestinal isolates, including E. faecalis, E. faecium, and vancomycin-resistant enterococci (VRE), revealed a diversity of levels of EbpA expression and fibrinogen-binding efficiency in vitro Strikingly, analysis of 10 strains representative of fibrinogen-binding diversity demonstrated that, irrespective of EbpA levels, EbpA NTD antibodies were universally protective. The results indicate that, despite diversity in levels of fibrinogen binding, strategies that target the disruption of EbpA NTD -fibrinogen interactions have considerable promise for treatment of CAUTI. Urinary catheterization is a routine medical procedure, and it has been estimated that 30 million Foley catheters are used annually in the United States. Importantly, placement of a urinary catheter renders the patient susceptible to developing a catheter-associated urinary tract infection, accounting for 1 million cases per year. Additionally, these infections can lead to serious complications, including bloodstream infection and death. Enterococcus strains

  15. Videofluoroscopy-guided balloon dilatation for treatment of severe pharyngeal dysphagia.

    PubMed

    Yabunaka, Koichi; Konishi, Hideki; Nakagami, Gojiro; Matsuo, Jyunko; Noguchi, Atsushi; Sanada, Hiromi

    2015-01-01

    Balloon dilatation is a widely accepted technique in the management of esophageal and other types of gastrointestinal strictures, but it is rarely used for the treatment of pharyngeal dysphagia. Therefore, the aim of our prospective study was to evaluate the use of videofluoroscopy-guided balloon dilatation (VGBD) for the treatment of severe pharyngeal dysphagia. The study included 32 stroke patients who had been diagnosed with oral and/or pharyngeal dysphagia. All patients underwent dilatation of the esophageal inlet using a balloon catheter under videofluoroscopic guidance during one or more sessions. Following esophageal dilatation, manual feeding was provided twice weekly. VGBD was effective in 10 out of 32 patients; however, the remaining 22 patients were unable to attempt oral food consumption because aspiration was not completely resolved on videofluoroscopy. According to this case series, VGBD may provide treatment for patients with severe pharyngeal dysphagia, who have not consumed food orally for a long period of time.

  16. Integrated multimodal-catheter imaging unveils principal relationships among ventricular electrical activity, anatomy, and function.

    PubMed

    Rao, Liyun; Ling, Yuesheng; He, Renjie; Gilbert, April L; Frangogiannis, Nikolaos G; Wang, Jianwen; Nagueh, Sherif F; Khoury, Dirar S

    2008-02-01

    Multiple imaging modalities are employed independent of one another while managing complex cardiac arrhythmias. To combine electrical, anatomical, and functional imaging in a single catheter system, we developed a balloon catheter that carried 64 electrodes on its surface and an intracardiac echocardiography (ICE) catheter through a central lumen. The catheter system was inserted, and the balloon was inflated inside the left ventricle (LV) of eight dogs with 6-wk-old infarction, created by occlusion in the left anterior descending coronary artery. Anatomy was constructed by ICE imaging (9 MHz) through the balloon. Single-beat noncontact mapping (NCM) was performed via the multielectrode array to reconstruct unipolar endocardial electrograms during sinus rhythm. Standard contact mapping (CM) of the endocardium was also carried out for reference. Myocardial infarction in anterior LV extending from the middle to apical regions was localized both by ICE and NCM and validated by CM and pathology. The overall difference in the activation times between NCM and CM was 3 +/- 1 ms. Unipolar voltage in infarcted middle anterior LV was smaller than the voltage in normal middle inferior LV both by NCM (11 +/- 4 vs. 16 +/- 3 mV; P = 0.002) and CM (11 +/- 3 vs. 20 +/- 4 mV; P < 0.001). Unipolar voltage was also inversely related to infarct transmurality, both by NCM (r = -0.87; P = 0.005) and CM (r = -0.94; P < 0.001). The infarct area by ICE (7.7 +/- 2.9 cm(2)) was in agreement with CM (bipolar voltage, <1 mV; and area, 7.6 +/- 3.3 cm(2); r = 0.80; P = 0.016). Meanwhile, the voltage threshold that depicted the infarct area by NCM was directly related to the smallest unipolar voltage reconstructed within the infarct (r = 0.96; P < 0.001). In conclusion, combining NCM and ICE imaging in a single catheter system is feasible. The preclinical development of such an integrated system and its evaluation in experimental myocardial infarction demonstrate capabilities for single

  17. Endoscopic minor papilla balloon dilation for the treatment of symptomatic pancreas divisum.

    PubMed

    Yamamoto, Natsuyo; Isayama, Hiroyuki; Sasahira, Naoki; Tsujino, Takeshi; Nakai, Yousuke; Miyabayashi, Koji; Mizuno, Suguru; Kogure, Hirofumi; Sasaki, Takashi; Hirano, Kenji; Tada, Minoru; Koike, Kazuhiko

    2014-08-01

    A subpopulation of patients with pancreas divisum experience symptomatic events such as recurrent acute pancreatitis and chronic pancreatitis. Minor papilla sphincterotomy has been reported as being an effective treatment. The aim of this study was to evaluate the safety and efficacy of endoscopic balloon dilation for the minor papilla. Between 2000 and 2012, 16 patients were retrospectively included in this study. After endoscopic balloon dilation for the minor papilla was received, a pancreatic stent or a nasal pancreatic drainage catheter was placed for 1 week. If a stricture or obstruction was evident, it was treated with balloon dilation followed by long-term stent placement (1 year). When an outflow of pancreatic juice was disturbed by a pancreatic stone, endoscopic stone extraction was performed. Balloon dilation and stent placement were achieved and were successful in all the cases (16/16; 100%). Clinical improvement was achieved in 7 (84.7%) of the 9 patients with recurrent acute pancreatitis and in 6 (85.7%) of the 7 patients with chronic pancreatitis. Early complications were observed in 1 (6.3%) patient. Pancreatitis or bleeding related to balloon dilation was not observed. Endoscopic balloon dilation for the minor papilla is feasible for the management of symptomatic pancreas divisum.

  18. Mid-infrared coronary laser angioplasty with multifiber catheters

    NASA Astrophysics Data System (ADS)

    White, Christopher J.; Ramee, Stephen R.; Collins, Tyrone J.

    1993-06-01

    Mid-infrared laser wavelengths offer advantages as a source for coronary angioplasty based upon the excellent fiberoptic transmission and the enhanced tissue absorption of these photons. We report the results of a pilot clinical trial of a Holmium:YAG (2.1 micrometers ) coronary laser angioplasty using a prototype (1.6 mm and 2.0 mm) multifiber catheters. Coronary laser angioplasty with or without adjunctive balloon angioplasty or directional atherectomy was performed in 14 patients with 17 coronary stenoses. Laser success was obtained in 13/14 (93%) patients and 16/17 (94%) lesions. Uncomplicated procedural success was achieved in 9/14 (64%) patients and 12/17 (71%) lesions. Our initial laser success rate was very encouraging using this prototype multifiber catheter with a holmium:YAG laser. However, our overall procedural success rate was disappointing, and not superior to that expected with conventional angioplasty alone. The holmium laser remains an attractive energy source for laser angioplasty, but its utility is limited by catheters which create inadequate channels for stand-alone laser angioplasty.

  19. The pulmonary artery catheter: a critical reappraisal.

    PubMed

    Gidwani, Umesh K; Mohanty, Bibhu; Chatterjee, Kanu

    2013-11-01

    Balloon floatation pulmonary artery catheters (PACs) have been used for hemodynamic monitoring in cardiac, medical, and surgical intensive care units since the 1970s. With the availability of newer noninvasive diagnostic modalities, particularly echocardiography, the frequency of diagnostic pulmonary artery catheterization has declined. In this review, the evolution of PACs, the results of nonrandomized and randomized studies in various clinical conditions, the uses and abuses of bedside hemodynamic monitoring, and current indications for pulmonary artery catheterization are discussed. Copyright © 2013 Elsevier Inc. All rights reserved.

  20. Temporary placement of retrievable fully covered metallic stents versus percutaneous balloon dilation in the treatment of benign biliary strictures.

    PubMed

    Kim, Jin Hyoung; Gwon, Dong Il; Ko, Gi-Young; Sung, Kyu-Bo; Lee, Sung Koo; Yoon, Hyun-Ki; Shin, Ji Hoon; Song, Ho-Young

    2011-06-01

    To compare retrospectively percutaneous transhepatic primary placement of a retrievable self-expanding metallic stent with percutaneous balloon dilation for the treatment of benign biliary strictures. From 2005-2009, 66 patients with benign biliary strictures in whom an endoscopic approach failed or in whom such an approach was inaccessible were evaluated. Of 66 patients, 31 underwent balloon dilation, and 35 underwent temporary metallic stent placement. The etiologies of the benign strictures were anastomotic stricture after surgery (n = 54), stricture secondary to intraoperative injury (n = 9), inflammatory stricture (n = 2), and stricture secondary to trauma (n = 1). The primary patency rates were significantly better in the stent group (87% at 3 years) than in the balloon group (44% at 3 years; P = .022). The indwelling period of percutaneous transhepatic biliary drainage (PTBD) catheters after the initial procedure was able to be significantly reduced in the stent group (median 2.5 months) compared with the balloon group (median 4.5 months; P = .001). Significant bleeding (associated with PTBD) occurred in one patient in the balloon group. In the stent group, stent migration occurred in two patients, and one patient underwent surgery for stent removal after failure of removal under fluoroscopic guidance. Percutaneous primary placement of a retrievable self-expanding metallic stent showed superior intermediate-term results compared with percutaneous balloon dilation for the treatment of benign biliary strictures. In addition, the indwelling period of PTBD catheters can be significantly reduced using temporary stent placement. Copyright © 2011 SIR. Published by Elsevier Inc. All rights reserved.

  1. Minimally invasive fluoroscopic percutaneous peritoneal dialysis catheter salvage.

    PubMed

    Narayan, Rajeev; Fried, Terrance; Chica, Gerardo; Schaefer, Mathew; Mullins, Daniel

    2014-06-01

    Peritoneal dialysis catheter (PDC) dysfunction can often be treated fluoroscopically by manipulation with wire, balloon or stiff stylet, saving surgical intervention for refractory cases. We describe an enhanced percutaneous approach to PDC salvage that can lead to a more definitive intervention and salvage for cases refractory to fluoroscopic manipulation. In five cases of PD catheter malfunction, the deep cuff was dissected free after a 0.035 hydrophilic wire was passed into the peritoneum through the PDC. Only the intraperitoneal portion of the PDC was explanted. The PDC was cleared of obstruction and omentum. The intraperitoneal portion of the PDC was reimplanted over wire via a peel-away sheath and the deep cuff sutured. Omental entrapment was present in three of five patients and fibrin occlusion in four of the five cases. All catheters were repaired successfully by the described technique. Post procedure, 3-5 days of lower volume, recumbent PD exchanges were performed prior to full-dose PD. No perioperative complications or leaks were noted. All PDCs were patent at 6 months. One patient required laparoscopy for recurrent omental wrapping 3 months post intervention. PDC salvage in this manner is a cost-effective alternative to laparoscopic repair of PDCs failing catheter manipulation. The infection barrier afforded by the original superficial cuff and subcutaneous tunnel is maintained. PD can be resumed immediately. Only refractory cases need laparoscopy. This procedure allows for a more definitive correction of catheter migration and obstruction, avoids placement of a new PDC or temporary hemodialysis, is cost-effective and expands percutaneous options for dysfunctional PD catheters.

  2. Bi-layer sandwich film for antibacterial catheters

    PubMed Central

    Schamberger, Florian; Zare, Hamideh Heidari; Bröskamp, Sara Felicitas; Jocham, Dieter

    2017-01-01

    Background: Approximately one quarter of all nosocomial infections can be attributed to the urinary tract. The infections are supposed to be mainly caused by implantations of urethral catheters and stents. A new catheter design is introduced with the aim to lower the high number of nosocomial urethral infections. In order to avoid limitations to use, the design is first applied to conventional commercially available balloon catheters. Results: The main feature of the design is a sandwich layer on both sides of the catheter wall, which is composed of a fragmented base layer of silver capped by a thin film of poly(p-xylylene). This top layer is mainly designed to release a controlled amount of Ag+ ions, which is bactericidal, but not toxic to humans. Simultaneously, the lifetime is prolonged to at least one year. The base layer is electrolessly deposited applying Tollens’ reagens, the cap layer is deposited by using chemical vapor deposition. Conclusion: The three main problems of this process, electroless deposition of a fragmented silver film on the surface of an electrically insulating organic polymer, irreproducible evaporation during heating of the precursor, and exponential decrease of the layer thickness along the capillary, have been solved trough the application of a simple electrochemical reaction and two standard principles of physics: Papin’s pot and the principle of Le Chatelier. PMID:29046846

  3. Bi-layer sandwich film for antibacterial catheters.

    PubMed

    Franz, Gerhard; Schamberger, Florian; Zare, Hamideh Heidari; Bröskamp, Sara Felicitas; Jocham, Dieter

    2017-01-01

    Background: Approximately one quarter of all nosocomial infections can be attributed to the urinary tract. The infections are supposed to be mainly caused by implantations of urethral catheters and stents. A new catheter design is introduced with the aim to lower the high number of nosocomial urethral infections. In order to avoid limitations to use, the design is first applied to conventional commercially available balloon catheters. Results: The main feature of the design is a sandwich layer on both sides of the catheter wall, which is composed of a fragmented base layer of silver capped by a thin film of poly( p -xylylene). This top layer is mainly designed to release a controlled amount of Ag + ions, which is bactericidal, but not toxic to humans. Simultaneously, the lifetime is prolonged to at least one year. The base layer is electrolessly deposited applying Tollens' reagens, the cap layer is deposited by using chemical vapor deposition. Conclusion: The three main problems of this process, electroless deposition of a fragmented silver film on the surface of an electrically insulating organic polymer, irreproducible evaporation during heating of the precursor, and exponential decrease of the layer thickness along the capillary, have been solved trough the application of a simple electrochemical reaction and two standard principles of physics: Papin's pot and the principle of Le Chatelier.

  4. Safe percutaneous suprapubic catheterisation

    PubMed Central

    Goyal, NK; Goel, A; Sankhwar, SN

    2012-01-01

    INTRODUCTION We describe our technique of percutaneous suprapubic catheter insertion with special reference to steps that help to avoid common complications of haematuria and catheter misplacement. METHODS The procedure is performed using a stainless steel reusable trocar under local infiltrative anaesthesia, usually at the bedside. After clinical confirmation of a full bladder, the trocar is advanced into the bladder through a skin incision. Once the bladder is entered, the obturator is removed and the assistant inserts a Foley catheter followed by rapid balloon inflation. Slight traction is applied to the catheter for about five minutes. Patients with previous lower abdominal surgery, an inadequately distended bladder or acute pelvic trauma do not undergo suprapubic catheterisation using this method. RESULTS The procedure was performed in 72 men (mean age: 42.4 years, range: 18–78 years) with urinary retention with a palpable bladder. The average duration of the procedure was less than five minutes. No complications were noted in any of the patients. CONCLUSIONS Trocar suprapubic catheter insertion is a safe and effective bedside procedure for emergency bladder drainage and can be performed by resident surgeons. The common complications associated with the procedure can be avoided with a few careful steps. PMID:23131233

  5. A novel balloon assisted two-stents telescoping technique for repositioning an embolized stent in the pulmonary conduit.

    PubMed

    Kobayashi, Daisuke; Gowda, Srinath T; Forbes, Thomas J

    2014-08-01

    A 9-year-old male, with history of pulmonary atresia and ventricular septal defect, status post complete repair with a 16 mm pulmonary homograft in the right ventricular outflow tract (RVOT) underwent 3110 Palmaz stent placement for conduit stenosis. Following deployment the stent embolized proximally into the right ventricle (RV). We undertook the choice of repositioning the embolized stent into the conduit with a transcatheter approach. Using a second venous access, the embolized stent was carefully maneuvered into the proximal part of conduit with an inflated Tyshak balloon catheter. A second Palmaz 4010 stent was deployed in the distal conduit telescoping through the embolized stent. The Tyshak balloon catheter was kept inflated in the RV to stabilize the embolized stent in the proximal conduit until it was successfully latched up against the conduit with the deployment of the overlapping second stent. One year later, he underwent Melody valve implantation in the pre-stented conduit relieving conduit insufficiency. This novel balloon assisted two-stents telescoping technique is a feasible transcatheter option to secure an embolized stent from the RV to the RVOT. © 2014 Wiley Periodicals, Inc.

  6. Immediate Outcome of Balloon Mitral Valvuloplasty with JOMIVA Balloon during Pregnancy

    PubMed Central

    Ramasamy, Ramona; Kaliappan, Tamilarasu; Gopalan, Rajendiran; Palanimuthu, Ramasmy; Anandhan, Premkrishna

    2017-01-01

    Introduction Rheumatic mitral stenosis is the most common Valvular Heart Disease encountered during pregnancy. Balloon Mitral Valvuloplasty (BMV) is one of the treatment option available if the symptoms are refractory to the medical management and the valve anatomy is suitable for balloon dilatation. BMV with Inoue balloon is the most common technique being followed worldwide. Over the wire BMV is a modified technique using Joseph Mitral Valvuloplasty (JOMIVA) balloon catheter which is being followed in certain centres. Aim To assess the immediate post procedure outcome of over the wire BMV with JOMIVA balloon. Materials and Methods Clinical and echocardiographic parameters of pregnant women with significant mitral stenosis who underwent elective BMV with JOMIVA balloon in our institute from 2005 to 2015 were analysed retrospectively. Severity of breathlessness (New York Heart Association Functional Class), and duration of pregnancy was included in the analysis. Pre procedural echocardiographic parameters which included severity of mitral stenosis and Wilkin’s scoring were analysed. Clinical, haemodynamic and echocardiographic outcomes immediately after the procedure were analysed. Results Among the patients who underwent BMV in our Institute 38 were pregnant women. Twenty four patients (63%) were in New York Heart Association (NYHA) Class III. All of them were in sinus rhythm except two (5%) who had atrial fibrillation. Thirty four patients (89.5%) were in second trimester of pregnancy at the time of presentation and four (10.5%) were in third trimester. Echocardiographic analysis of the mitral valve showed that the mean Wilkin’s score was 7.3. Mean mitral valve area pre procedure was 0.8 cm2. Mean gradient across the valve was 18 mmHg. Ten patients (26.5%) had mild mitral regurgitation and none had more than mild mitral regurgitation. Thirty six patients had pulmonary hypertension as assessed by tricuspid regurgitation jet velocity. All of them underwent BMV

  7. The development of a pseudo-chamber after balloon pulmonary angioplasty: long-term complications of balloon pulmonary angioplasty.

    PubMed

    Sugiyama, Hisashi; Kise, Hiroaki; Toda, Takako; Hoshiai, Minako

    2016-11-01

    We experienced a rare complication where extravasation developed a pseudo-chamber long after the balloon pulmonary angioplasty for supravalvular pulmonary stenosis. A 3-month-old girl was diagnosed with an anomalous origin of the left coronary artery from the pulmonary artery. She underwent the Takeuchi procedure at 10 months of age. During the follow-up, the supravalvular pulmonary stenosis deteriorated, and was treated by balloon pulmonary angioplasty with the double balloon technique catheter at 6 years of age. Angiography at the main pulmonary artery showed a small amount of extravasation contrast medium after the procedure. Follow-up echocardiography showed a diminished extravasation hemorrhage. Twelve years later, right ventricular enlargement due to pulmonary regurgitation had been observed on echocardiography. In addition, abnormal echo free space was detected at the left posterior of the left atrium. Enhanced computed tomography clearly demonstrated there was an orifice and extent of the pseudo-chamber. Surgical findings revealed a large tear just distal to the coronary tunnel. We speculated that extravasation blood was limited in the perivascular area early after the procedure but eventually reached the non-adhesive oblique pericardial sinus with age. Consequently, pulmonary to oblique pericardial sinus communication was established and looked like a pseudo-chamber long after the procedure. In conclusion, even if extravasation seems to be limited immediately after the balloon pulmonary angioplasty, it could expand for non-adhesive space and could develop a huge blood space like chamber. Long-term careful observation should be necessary for extravasation of pulmonary artery even with surgical adhesion.

  8. Old habits die hard; does early urinary catheter removal affect kidney size, bacteriuria and UTI after renal transplantation?

    PubMed

    Akbari, Roghayeh; Rahmani Firouzi, Sedigheh; Akbarzadeh-Pasha, Abazar

    2017-01-01

    Introduction: Renal transplantation is the treatment of choice in chronic renal failure patients. Objectives: The purpose of this study was to evaluate the impact of urinary catheter removal time on transplanted kidney size and incidence of asymptomatic bacteriuria and urinary tract infections (UTIs). Patients and Methods: This retrospective cohort study evaluated the clinical outcomes of 109 consecutive live donor renal transplant recipients from December 2011 to July 2014. Routine ultrasound examinations were performed on donor's kidney prior to operation and one month later. Kidney volume was calculated. UTI and bacteriuria were evaluated one month later. Patients were divided into two groups based on time of Foley catheter removal (before and after fifth day posttransplantation). Results: In this study 74 males (67.9%) and 35 females (32.1%) were evaluated. Sixty-six patients (57.92%) were in group 1. None of the patients with positive urine culture had UTI but bacteriuria occurred in all of them (21.1%). Bacteriuria time after transplantation and catheter removal was significantly later in group 1 and it was not different in female group but they were later in male group. The mean renal volume increase was positively correlated to renal transplant recipient and donor's age and donor's body mass index (BMI) ( P <0.05). Conclusion: This study showed that the time of catheter removal after kidney transplantation does not affect incidence of UTI but increases the probability of bacteria in men whose catheter was removed within 5 days after transplantation. We also found that the renal volume change is not associated with catheter removal time and bacteriuria.

  9. Use of Intermediate Guide Catheters as an Adjunct in Extracranial Embolization to Avoid Onyx Reflux into the Anastomotic Vasculature

    PubMed Central

    Puri, Ajit S; Kühn, Anna L; Hou, Samuel Y; Wakhloo, Ajay K

    2014-01-01

    Summary Onyx is a non-adhesive polymer used for embolization of arteriovenous malformations and dural arteriovenous fistulas (DAVFs). The limiting factor for Onyx embolization is usually the amount of microcatheter reflux, which can be safely tolerated. The dual microcatheter technique, compliant balloon use proximally and the use of the dual lumen Scepter balloon have been described to prevent and limit proximal Onyx reflux. We describe the use the Navien 058 intermediate guide catheter to accept the Onyx reflux in its lumen and possibly also serve as a mechanical barrier to avoid reflux into the anastomotic channel connecting the occipital artery to the vertebral artery during DAVF embolization via the occipital artery. Complete embolization of the DAVF was achieved using the lumen of the Navien catheter to accept aggressive Onyx reflux. Complete cure of the DAVF was obtained with Onyx cast filling the entire venous pouch. Besides providing distal access support, intermediate guide catheters can also prevent embolic material reflux by accepting reflux into the lumen and providing a mechanical barrier. PMID:25207904

  10. Intracavitary moderator balloon combined with 252Cf brachytherapy and boron neutron capture therapy, improving dosimetry in brain tumour and infiltrations

    PubMed Central

    Brandão, S F

    2015-01-01

    Objective: This article proposes a combination of californium-252 (252Cf) brachytherapy, boron neutron capture therapy (BNCT) and an intracavitary moderator balloon catheter applied to brain tumour and infiltrations. Methods: Dosimetric evaluations were performed on three protocol set-ups: 252Cf brachytherapy combined with BNCT (Cf-BNCT); Cf-BNCT with a balloon catheter filled with light water (LWB) and the same set-up with heavy water (HWB). Results: Cf-BNCT-HWB has presented dosimetric advantages to Cf-BNCT-LWB and Cf-BNCT in infiltrations at 2.0–5.0 cm from the balloon surface. However, Cf-BNCT-LWB has shown superior dosimetry up to 2.0 cm from the balloon surface. Conclusion: Cf-BNCT-HWB and Cf-BNCT-LWB protocols provide a selective dose distribution for brain tumour and infiltrations, mainly further from the 252Cf source, sparing the normal brain tissue. Advances in knowledge: Malignant brain tumours grow rapidly and often spread to adjacent brain tissues, leading to death. Improvements in brain radiation protocols have been continuously achieved; however, brain tumour recurrence is observed in most cases. Cf-BNCT-LWB and Cf-BNCT-HWB represent new modalities for selectively combating brain tumour infiltrations and metastasis. PMID:25927876

  11. Use of real time three-dimensional transesophageal echocardiography in intracardiac catheter based interventions.

    PubMed

    Perk, Gila; Lang, Roberto M; Garcia-Fernandez, Miguel Angel; Lodato, Joe; Sugeng, Lissa; Lopez, John; Knight, Brad P; Messika-Zeitoun, David; Shah, Sanjiv; Slater, James; Brochet, Eric; Varkey, Mathew; Hijazi, Ziyad; Marino, Nino; Ruiz, Carlos; Kronzon, Itzhak

    2009-08-01

    Real-time three-dimensional (RT3D) echocardiography is a recently developed technique that is being increasingly used in echocardiography laboratories. Over the past several years, improvements in transducer technologies have allowed development of a full matrix-array transducer that allows acquisition of pyramidal-shaped data sets. These data sets can be processed online and offline to allow accurate evaluation of cardiac structures, volumes, and mass. More recently, a transesophageal transducer with RT3D capabilities has been developed. This allows acquisition of high-quality RT3D images on transesophageal echocardiography (TEE). Percutaneous catheter-based procedures have gained growing acceptance in the cardiac procedural armamentarium. Advances in technology and technical skills allow increasingly complex procedures to be performed using a catheter-based approach, thus obviating the need for open-heart surgery. The authors used RT3D TEE to guide 72 catheter-based cardiac interventions. The procedures included the occlusion of atrial septal defects or patent foramen ovales (n=25), percutaneous mitral valve repair (e-valve clipping; n=3), mitral balloon valvuloplasty for mitral stenosis (n=10), left atrial appendage obliteration (n=11), left atrial or pulmonary vein ablation for atrial fibrillation (n=5), percutaneous closures of prosthetic valve dehiscence (n=10), percutaneous aortic valve replacement (n=6), and percutaneous closures of ventricular septal defects (n=2). In this review, the authors describe their experience with this technique, the added value over multiplanar two-dimensional TEE, and the pitfalls that were encountered. The main advantages found for the use RT3D TEE during catheter-based interventions were (1) the ability to visualize the entire lengths of intracardiac catheters, including the tips of all catheters and the balloons or devices they carry, along with a clear depiction of their positions in relation to other cardiac structures, and

  12. A Methodological Response from the Field to Douglas Foley: Critical Bifocality and Class Cultural Productions in Anthropology and Education

    ERIC Educational Resources Information Center

    Weis, Lois; Fine, Michelle

    2013-01-01

    In this paper we are explicitly in conversation with Doug Foley's recently published paper in "AEQ." Given our shared commitment to the linkages between intersectionality and broader social and economic arrangements, two noted ethnographers argue that the paradigmatic shift highlighted by Foley demands detailed attention to what…

  13. The glider balloon: a useful device for the treatment of bifurcation lesions.

    PubMed

    Briguori, Carlo; Visconti, Gabriella; Donahue, Michael; Chiariello, Giovanni Alfonso; Focaccio, Amelia

    2013-10-09

    Final kissing balloon dilatation (FKBD) is a recommended final step in case of treatment of bifurcation lesions by two stents approaches. Furthermore, dilatation of the side branch (SB) may be necessary following main vessel (MV) stenting. Occasionally, recrossing the stent struts with a balloon is hampered because the tip hits a stent strut. The Glider (TriReme Medical, Pleasanton, CA) is a dedicated balloon designed for crossing through struts of deployed stents toward a SB. From October 2010 to January 2012, FKBD was attempted in 236 consecutive bifurcation lesions treated in our Institution. FKBD was successfully performed by conventional balloon catheters in 221 (93.5%) lesions (Conventional group). In the remaining 15 (6.5%) lesions, where a conventional balloon failed to cross the stent strut, the Glider balloon was attempted (Glider group). The angle beta (between the axis of the MV after the branch point and the SB axis at the point of divergence) was wider in the Glider group (83±17° versus 65±27°; p=0.032). A trend toward an higher rate of the true bifurcation lesions was observed in the Glider group (93% versus 70.5%; p=0.07). The Glider balloon successfully crossed through MV stent struts toward a SB in 12 patients (80%), whereas failed in the remaining 3 patients. The Glider balloon represents an unique bail-out device which offers an effective rescue strategy for recrossing stent struts during complex bifurcation stenting. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  14. Minimally invasive per-catheter occlusion and dilation procedures for congenital cardiovascular abnormalities in dogs.

    PubMed

    Tobias, Anthony H; Stauthammer, Christopher D

    2010-07-01

    With ever-increasing sophistication of veterinary cardiology, minimally invasive per-catheter occlusion and dilation procedures for the treatment of various congenital cardiovascular abnormalities in dogs have become not only available, but mainstream. Much new information about minimally invasive per-catheter patent ductus arteriosus occlusion has been published and presented during the past few years. Consequently, patent ductus arteriosus occlusion is the primary focus of this article. Occlusion of other less common congenital cardiac defects is also briefly reviewed. Balloon dilation of pulmonic stenosis, as well as other congenital obstructive cardiovascular abnormalities is discussed in the latter part of the article.

  15. Initial Experience and Feasibility of the New Low-Profile Stingray Catheter as Part of the Antegrade Dissection and Re-Entry Revascularization Strategy for Coronary Chronic Total Occlusions.

    PubMed

    Maeremans, Joren; Palmers, Pieter-Jan; Dens, Joseph

    2017-01-31

    BACKGROUND During antegrade dissection re-entry (ADR) of chronic total occlusions (CTO), the first-generation Stingray catheter requires the use of large-bore guides (sheathless 7.5 Fr or 8 Fr), which increases the risk for access site-related complications and compromises radial approaches. Smaller guiding sizes necessitate long guidewires (e.g., 300 cm) or guidewire extensions for catheter advancement or removal. However, friction between guides and the Stingray catheter can result in unstable guidewire position or unintentional removal. Furthermore, failure to deliver the catheter at the distal re-entry zone is a common problem. To overcome issues of deliverability and reduce the need for pre-dilatations, with its inherent risk of creating subintimal hematomas, the Stingray low-profile (LP) balloon catheter was developed. CASE REPORT We describe 3 cases of successful application of the novel Stingray LP catheter during ADR. In all cases, 7 Fr guiding catheters were successfully used in combination with the device. The lower profile facilitated a good exchange and delivery of the device, without the need for balloon pre-dilatations in 2 cases. This resulted in a limited subintimal plane, enabling a smooth puncture into the true lumen. One case presented with extreme levels of calcification and tortuosity, resulting in a high degree of friction, despite the lower catheter profile. No in-hospital coronary or access site-related complications occurred. CONCLUSIONS This case report illustrates the feasibility of the Stingray LP catheter for the treatment of CTOs via the ADR technique. The lower profile of the catheter potentially increases the deliverability, safety, and exchangeability of the device.

  16. Catheter interventional treatment of congenital portosystemic venous shunts in childhood.

    PubMed

    Knirsch, Walter; Benz, Dominik C; Bühr, Patrick; Quandt, Daniel; Weber, Roland; Kellenberger, Christian; Braegger, Christian P; Kretschmar, Oliver

    2016-06-01

    The study aimed on the catheter interventional treatment of congenital portosystemic venous shunt (CPSVS) in childhood and the impact on vascular growth of hypoplastic portal veins. Clinical course and follow up of partial or complete closure of CPSVS are described. CPSVS is a very rare vascular malformation of the portal venous drainage resulting in potentially life threatening abdominal, pulmonary, cerebral, and cardiac complications. The anatomic type, clinical course, and diagnosis must be determined for optimal management. Single centre case series. Eight (6 female) children with extrahepatic (n = 5) and intrahepatic (n = 3) CPSVS were diagnosed invasively by catheterization, including test balloon occlusion of the shunt and simultaneous retrograde angiography, and treated by catheter interventions (n = 5) with partial (n = 2) and complete (n = 3) occlusion of CPSVS at a median age of 3.9 years (range 0.7-21). Congenital heart disease (CHD) was the most frequent associated organ manifestation (n = 5) followed by mild to severe pulmonary arterial hypertension (n = 4), hepatopulmonary syndrome (n = 2), and portosystemic encephalopathy (n = 1). CHD was simple (n = 3) or complex type (n = 2). Three patients were untreated so far, because they were in excellent clinical condition at an age <1 year, refused treatment, or planned for later treatment. Accurate invasive diagnosis of CPSVS with test balloon occlusion of the shunt is mandatory to depict the anatomic situation. Catheter interventional treatment of CPSVS offers a feasible and safe approach with complete or partial closure of the vascular malformation inducing potentially significant vascular growth of a former hypoplastic portal venous system. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.

  17. Vascular occlusion with a balloon-expandable stent occluder.

    PubMed

    Moss, J G; Laborde, J C; Clem, M C; Rivera, F J; Encarnacion, C E; Meyer, K B; Palmaz, J C

    1994-05-01

    To evaluate the effectiveness of a new vascular occlusion device. The device was created by coating a balloon-expandable stent with a silicone sleeve that tapers to a blind-ended nozzle at its leading end. Once crimp-mounted on an angioplasty balloon catheter, the device is introduced over a guide wire through a small end hole in the nozzle. The device was tested for stability and occlusive ability. No migration was measured over a pulsatile pulse range of 50-300 mm Hg, and mean flow rate in the occluded vessel was reduced from 443 mL/min +/- 99 (standard deviation) to 1.9 mL/min +/- 2.7. Subsequently, 12 arteries were occluded in three dogs, and immediate vascular occlusion was achieved in all vessels. An arteriovenous fistula was created in another six dogs and was successfully occluded with the device. Follow-up arteriography at 3 months demonstrated persistent occlusion with no migration of the device. This new occlusive device offers immediate vascular occlusion with excellent stability.

  18. 3 CFR 9046 - Proclamation 9046 of October 28, 2013. Death of Thomas S. Foley Former Speaker of the House of...

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... Thomas S. Foley Former Speaker of the House of Representatives 9046 Proclamation 9046 Presidential Documents Proclamations Proclamation 9046 of October 28, 2013 Proc. 9046 Death of Thomas S. Foley Former Speaker of the House of RepresentativesBy the President of the United States of America A Proclamation As...

  19. [Mitral valvuloplasty with double balloon catheter. Analysis of 200 cases].

    PubMed

    Gomes, N L; Esteves, C A; Braga, S L; Ramos, A I; Meneghelo, Z M; Mattos, L A; Pontes Júnior, S C; Arnoni, A S; Fontes, V F; Sousa, J E

    1992-04-01

    To study the immediate clinical, echocardiographic and hemodynamic results of 200 patients who underwent percutaneous mitral balloon valvotomy (PMV) with double balloon technique. Two hundred patients were submitted to PVM for treatment of congestive heart failure secondary to severe mitral stenosis, between August 1987 to July 1991. Their mean age was 35.2 years, and 86.5% were female patients: 81% of them was in functional class, New York Heart Association (NYHA) III or IV; 4% was in atrial fibrilation and 4% had previous surgical commissurotomy. PMV was successfully performed in 89% of the patients. The mitral valve area, by pressure half time method, increased from 0.91 +/- 0.27 to 2.10 +/- 0.47 cm2, p < 0.001; the mean mitral gradient decreased from 20.86 +/- 6.16 to 4.26 +/- 3.13 mmHg, p < 0.001; the left atrium and mean pulmonary artery pressure decreased from 22.3 +/- 7.1 to 11.9 +/- 8.3 and 36.47 +/- 12.93 to 24.56 +/- 9.98 mmHg, p < 0.001, respectively. Complications related to transeptal technique occurred in 12 patients, which resulted in cardiac tamponade in 5 and death in 1. In 19 patients the punction of the atrial septum could not be performed. Mitral regurgitation (MR) immediately after PMV appeared 1+ or more grade in 50 patients, increased in 8 patients and remained unchanged in 11 patients. Ten patients needed mitral valve replacement in the first 48h after PMV, for treatment of severe MR. PMV produces excellent immediate results and can be considered an alternative to surgery for the relief of mitral stenosis.

  20. Incremental balloon deflation following complete resuscitative endovascular balloon occlusion of the aorta results in steep inflection of flow and rapid reperfusion in a large animal model of hemorrhagic shock.

    PubMed

    Davidson, Anders J; Russo, Rachel M; Ferencz, Sarah-Ashley E; Cannon, Jeremy W; Rasmussen, Todd E; Neff, Lucas P; Johnson, M Austin; Williams, Timothy K

    2017-07-01

    To avoid potential cardiovascular collapse after resuscitative endovascular balloon occlusion of the aorta (REBOA), current guidelines recommend methodically deflating the balloon for 5 minutes to gradually reperfuse distal tissue beds. However, anecdotal evidence suggests that this approach may still result in unpredictable aortic flow rates and hemodynamic instability. We sought to characterize aortic flow dynamics following REBOA as the balloon is deflated in accordance with current practice guidelines. Eight Yorkshire-cross swine were splenectomized, instrumented, and subjected to rapid 25% total blood volume hemorrhage. After 30 minutes of shock, animals received 60 minutes of Zone 1 REBOA with a low-profile REBOA catheter. During subsequent resuscitation with shed blood, the aortic occlusion balloon was gradually deflated in stepwise fashion at the rate of 0.5 mL every 30 seconds until completely deflated. Aortic flow rate and proximal mean arterial pressure (MAP) were measured continuously over the period of balloon deflation. Graded balloon deflation resulted in variable initial return of aortic flow (median, 78 seconds; interquartile range [IQR], 68-105 seconds). A rapid increase in aortic flow during a single-balloon deflation step was observed in all animals (median, 819 mL/min; IQR, 664-1241 mL/min) and corresponded with an immediate decrease in proximal MAP (median, 30 mm Hg; IQR, 14.5-37 mm Hg). Total balloon volume and time to return of flow demonstrated no correlation (r = 0.016). This study is the first to characterize aortic flow during balloon deflation following REBOA. A steep inflection point occurs during balloon deflation that results in an abrupt increase in aortic flow and a concomitant decrease in MAP. Furthermore, the onset of distal aortic flow was inconsistent across study animals and did not correlate with initial balloon volume or relative deflation volume. Future studies to define the factors that affect aortic flow during balloon

  1. Urethral catheters and medical malpractice: a legal database review from 1965 to 2015.

    PubMed

    Awad, Mohannad A; Osterberg, E Charles; Chang, Helena; Gaither, Thomas W; Alwaal, Amjad; Fox, Ryan; Breyer, Benjamin N

    2016-10-01

    Urethral catheters (UCs) are commonly used in medicine and are associated with complications such as urinary tract infections (UTIs) and trauma. Given UC complications and their ubiquitous usage in healthcare, there is a potential for liability risk. We aim to explore litigation involving UC-related complications. The LexisNexis legal database was queried for all state and federal cases from January 1965 through October 2015 using the terms "urethral catheter" or "Foley catheter" in combination with "medical malpractice", "negligence", "medical error", and "trauma". Each case was reviewed for reported medical characteristics and legal aspects, including the outcome of the case. Our search yielded 29 cases. Urologists were the most common providers cited as defendants (21%), all of whom were successful in their defense. The most common malpractice claim was for traumatic insertion (48%). Pain was the most common type of damage claimed by plaintiffs (28%), followed by UTI (24%). Nineteen (66%) cases favored defendants, while 10 (34%) cases favored the plaintiffs, of which 2 (7%) were settled out of the court. In settled cases, the mean settlement received by plaintiffs was $55,750 (range, $25,000-$86,500). The mean award to plaintiffs for cases determined by the court was $112,991 (range, $4,000-$325,000). Despite widespread usage of UC over a 50-year period, lawsuits centered on UC misuse are rare at the state and federal court levels. Of litigated cases, urologists are commonly involved yet have successful defenses.

  2. A prospective study on evaluation of pathogenesis, biofilm formation, antibiotic susceptibility of microbial community in urinary catheter

    NASA Astrophysics Data System (ADS)

    Younis, Khansa Mohammed; Usup, Gires; Ahmad, Asmat

    2015-09-01

    This study is aimed to isolate, detect biofilm formation ability and antibiotic susceptibility of urinary catheter adherent microorganisms from elderly hospitalized patient at the Universiti Kebangsaan Malaysia Medical Center. Microorganisms were isolated from three samples of urinary catheters (UC) surface; one of the acute vascular rejection patient (UCB) and two from benign prostate hyperplasia patients (UCC and UCD). A total of 100 isolates was isolated with 35 from UCB, 38 (UCC) and 28 (UCD). Ninety six were identified as Gram-negative bacilli, one Gram-positive bacilli and three yeasts. Results of biofilm forming on sterile foley catheter showed that all the isolates can form biofilm at different degrees; strong biofilm forming: 32% from the 35 isolates (UCB), 25% out of 38 isolates (UCC), 26% out of 28 isolates (UCD). As for moderate biofilm forming; 3% from UCB, 10% from UCC and 2% from UCD. Weak biofilm forming in UCC (3%). The antibiotic susceptibility for (UCB) isolates showed highly resistant to ampicillin, novobiocin and penicillin 100 (%), kanamycin (97%), tetracycline (94%), chloramphenicol (91%), streptomycin (77%) and showed low level of resistance to gentamycin (17%), while all the isolates from (UCC-D) showed high resistant towards ampicillin and penicillin, novobiocin (94%), tetracycline (61%), streptomycin (53%), gentamycin (50%) and low level of resistance to kanamycin (48%), chloramphenicol (47%). The findings indicate that these isolates can spread within the community on urinary catheters surface and produce strong biofilm, therefore, monitoring antibiotic susceptibility of bacteria isolated in the aggregation is recommended.

  3. Complications of retrograde balloon cautery endopyelotomy.

    PubMed

    Schwartz, B F; Stoller, M L

    1999-11-01

    Adult ureteropelvic junction obstruction is increasingly managed with endoscopic techniques. Retrograde balloon cautery endopyelotomy is quick, requires minimal hospital stay and allows most patients a rapid return to work. The complication rate of retrograde balloon cautery endopyelotomy ranges from 13 to 34%, with vascular injury in 0 to 16% of patients. We report 5 uncommon complications, including 4 vascular injuries, that clinicians should be familiar with when using this technique. We reviewed 52 retrograde endoscopic endopyelotomy procedures performed during a 5-year period. There were 5 uncommon complications. Accessory lower pole renal artery injuries occurred in 3 patients, 1 of whom presented 12 days after endopyelotomy. Embolization was successfully performed in all 3 cases and none had subsequent hypertension. In 1 case a right ovarian vein laceration was not evident on preoperative or postoperative angiography. Emergency post-embolization abdominal exploration revealed a 2 mm. injury to the right ovarian vein before entering the right renal vein close to the ureteropelvic junction incision. Nephrectomy and ovarian vein ligature were curative. In 1 case the electrocautery wire broke intracorporeally after firing, resulting in a bobby pin-like configuration. Successful removal was accomplished by twisting the catheter and wrapping the wire around the tip, enabling atraumatic removal. Retrograde balloon cautery endopyelotomy is an emerging technology with potential adverse outcomes. The complications we noted are complex and potentially life threatening. Awareness of these complications may help avoid poor outcomes and expedite appropriate treatment.

  4. Cutting Balloon Angioplasty in the Treatment of Short Infrapopliteal Bifurcation Disease.

    PubMed

    Iezzi, Roberto; Posa, Alessandro; Santoro, Marco; Nestola, Massimiliano; Contegiacomo, Andrea; Tinelli, Giovanni; Paolini, Alessandra; Flex, Andrea; Pitocco, Dario; Snider, Francesco; Bonomo, Lorenzo

    2015-08-01

    To evaluate the safety, feasibility, and effectiveness of cutting balloon angioplasty in the management of infrapopliteal bifurcation disease. Between November 2010 and March 2013, 23 patients (mean age 69.6±9.01 years, range 56-89; 16 men) suffering from critical limb ischemia were treated using cutting balloon angioplasty (single cutting balloon, T-shaped double cutting balloon, or double kissing cutting balloon technique) for 47 infrapopliteal artery bifurcation lesions (16 popliteal bifurcation and 9 tibioperoneal bifurcation) in 25 limbs. Follow-up consisted of clinical examination and duplex ultrasonography at 1 month and every 3 months thereafter. All treatments were technically successful. No 30-day death or adverse events needing treatment were registered. No flow-limiting dissection was observed, so no stent implantation was necessary. The mean postprocedure minimum lumen diameter and acute gain were 0.28±0.04 and 0.20±0.06 cm, respectively, with a residual stenosis of 0.04±0.02 cm. Primary and secondary patency rates were estimated as 89.3% and 93.5% at 6 months and 77.7% and 88.8% at 12 months, respectively; 1-year primary and secondary patency rates of the treated bifurcation were 74.2% and 87.0%, respectively. The survival rate estimated by Kaplan-Meier analysis was 82.5% at 1 year. Cutting balloon angioplasty seems to be a safe and effective tool in the routine treatment of short/ostial infrapopliteal bifurcation lesions, avoiding procedure-related complications, overcoming the limitations of conventional angioplasty, and improving the outcome of catheter-based therapy. © The Author(s) 2015.

  5. Use of intermediate guide catheters as an adjunct in extracranial embolization to avoid onyx reflux into the anastomotic vasculature. A technical note.

    PubMed

    Puri, Ajit S; Kühn, Anna L; Hou, Samuel Y; Wakhloo, Ajay K

    2014-01-01

    Onyx is a non-adhesive polymer used for embolization of arteriovenous malformations and dural arteriovenous fistulas (DAVFs). The limiting factor for Onyx embolization is usually the amount of microcatheter reflux, which can be safely tolerated. The dual microcatheter technique, compliant balloon use proximally and the use of the dual lumen Scepter balloon have been described to prevent and limit proximal Onyx reflux. We describe the use the Navien 058 intermediate guide catheter to accept the Onyx reflux in its lumen and possibly also serve as a mechanical barrier to avoid reflux into the anastomotic channel connecting the occipital artery to the vertebral artery during DAVF embolization via the occipital artery. Complete embolization of the DAVF was achieved using the lumen of the Navien catheter to accept aggressive Onyx reflux. Complete cure of the DAVF was obtained with Onyx cast filling the entire venous pouch. Besides providing distal access support, intermediate guide catheters can also prevent embolic material reflux by accepting reflux into the lumen and providing a mechanical barrier.

  6. Treatment of congenital tracheal stenosis by balloon-expandable metallic stents in paediatric intensive care unit

    PubMed Central

    Xu, Xuan; Li, Dandan; Zhao, Shuyu; Liu, Xicheng; Feng, Zhichun; Ding, Hui

    2012-01-01

    The aim of this study was to evaluate the use of balloon-expandable metallic stents in the treatment of children with congenital tracheal stenosis in whom conventional therapy has failed. From 2010 to 2011, balloon-expandable metallic stents were implanted into the trachea of eight infants aged 2–20 months in the paediatric intensive care unit. The infants had severe airway obstruction caused by congenital tracheal stenosis. Tracheal stents were placed after intraluminal balloon dilatation of the tracheal stenosis, inserted with balloon catheters and implanted into the desired position bronchoscopically. The stents were 12 to 29 mm long and 4 mm in diameter. Seven children were relieved of airway obstruction after this procedure. However, a child died due to severe sepsis after the placement of bronchial stents. No granulation tissue developed over the stents in any of the children. Stents have been in place for 1–6 months after insertion without any other complication. Balloon-expandable metallic stents are effective in relieving airway obstruction by congenital tracheal stenosis in children. This technique may provide an important remedy for congenital tracheal stenosis in children. PMID:22361127

  7. Post-marketing surveillance in the published medical and grey literature for percutaneous transluminal coronary angioplasty catheters: a systematic review.

    PubMed

    Polisena, Julie; Forster, Alan J; Cimon, Karen; Rabb, Danielle

    2013-10-10

    Post-marketing surveillance (PMS) may identify rare serious incidents or adverse events due to the long-term use of a medical device, which was not captured in the pre-market process. Percutaneous transluminal coronary angioplasty (PTCA) is a non-surgical procedure that uses a balloon-tipped catheter to enlarge a narrowed artery. In 2011, 1,942 adverse event reports related to the use of PTCA catheters were submitted to the FDA by the manufacturers, an increase from the 883 reported in 2008. The primary research objective is to conduct a systematic review of the published and grey literature published between 2007 and 2012 for the frequency of incidents, adverse events and malfunctions associated with the use of PTCA catheters in patients with coronary artery disease (CAD). Grey literature has not been commercially published. We searched MEDLINE, EMBASE, the Cochrane Central Register of Controlled Trials and PubMed for medical literature on PMS for PTCA catheters in patients with CAD published between January 2007 and July 2012. We also searched the grey literature. This review included 11 studies. The in-hospital adverse events reported were individual cases of myocardial infarction and hematoma. In studies of patients with coronary perforation, more patients with balloon angioplasty were identified compared with patients who required stenting. Our systematic review illustrates that the volume and quality of PMS studies associated with the use of PTCA catheters in patients with CAD are low in the published and grey literature, and may not be useful sources of information for decisions on safety. In most studies, the objectives were not to monitor the long-term safety of the use of PTCA catheters in clinical practice. Future studies can explore the strengths and limitations of PMS databases administered by regulatory authorities.

  8. Ready or not, here they come: acting interns' experience and perceived competency performing basic medical procedures.

    PubMed

    Coberly, LeAnn; Goldenhar, Linda M

    2007-04-01

    To assess acting interns' (AI's) experience with and perceived level of competency performing 6 basic medical procedures. Fourth-year medical students at the University of Cincinnati (UCCOM) are required to complete 2 AI rotations in Internal Medicine. All AIs in 2003-2004 (n = 150) and 2004-2005 (n = 151) were asked to complete a survey about whether during each of their rotations they had performed and felt competent performing the following procedures: phlebotomy, intravenous (IV) catheter insertion, arterial blood gas (ABG), nasogastric (NG) tube insertion, lumbar puncture (LP), and Foley catheter insertion. Four hundred sixty-seven of 601 possible surveys (across both years and both rotations) were completed (78% response rate). During both rotations, relatively few students performed the procedures, ranging from 9% for Foley catheter insertion (24/208) to 50% for both ABG and NG tube insertion (130/259). The two procedures most often performed were ABG (range 46-50%) and NG tube insertion (range 42-50%). Feelings of competency varied from 12% (LP) to 82% (Foley catheter). Except for LP, if students performed a procedure at least once, they reported feeling more competent (range 85% for ABG to 96% for Foley catheter insertion). Among the students who performed LP during a rotation, many still did not feel competent performing LPs: 23 (74%) in rotation 1 and 20 (40%) in rotation 2. Many fourth-year students at UCCOM do not perform basic procedures during their acting internship rotations. Procedural performance correlates with feelings of competency. Lumbar puncture competency may be too ambitious a goal for medical students.

  9. Coronary and peripheral stenting in aorto-ostial protruding stents: The balloon assisted access to protruding stent technique.

    PubMed

    Helmy, Tarek A; Sanchez, Carlos E; Bailey, Steven R

    2016-03-01

    Treatment of aorto-ostial in-stent restenosis lesions represents a challenge for interventional cardiologists. Excessive protrusion of the stent into the aorta may lead to multiple technical problems, such as difficult catheter reengagement of the vessel ostium or inability to re-wire through the stent lumen in repeat interventions. We describe a balloon assisted access to protruding stent technique in cases where conventional coaxial engagement of an aorto-ostial protruding stent with the guide catheter or passage of the guide wire through the true lumen is not feasible. This technique is applicable both in coronary and peripheral arteries. © 2015 Wiley Periodicals, Inc.

  10. [Perioperative management of abdominal aortic balloon occlusion in patients complicated with placenta percteta: a case report].

    PubMed

    Zeng, Hong; Wang, Yan; Wang, Yang; Guo, Xiang-yang

    2015-12-18

    When placenta previa complicated with placenta percreta, the exposure of operative field is difficult and the routine methods are difficult to effectively control the bleeding, even causing life-threatening results. A 31-year-old woman, who had been diagnosed with a complete type of placenta previa and placenta percreta with bladder invasion at 34 weeks gestation. Her ultrasound results showed a complete type of placenta previa and there was a loss of the decidual interface between the placenta and the myometrium on the lower part of the uterus, suggestive of placenta increta. For further evaluation of the placenta, pelvis magnetic resonance imaging was performed, which revealed findings suspicious of a placenta percreta. She underwent elective cecarean section at 36 weeks of gestation. Firstly, two ureteral stents were placed into the bilateral ureter through the cystoscope. After the infrarenal abdominal aorta catheter was inserted via the femoral artery (9 F sheath ), subarachnoid anesthesia had been established. A healthy 2 510 g infant was delivered, with Apgar scores of 10 at 1 min and 10 at 5 min. Immediately after the baby was delivered, following which there was massive haemorrhage and general anaesthesia was induced. The balloon catheter was immediately inflated until the wave of dorsal artery disappeared. With the placenta retained within the uterus, a total hysterectomy was performed. The occluding time was 30 min. The intraoperative blood loss was 2 500 mL. The occluding balloon was deflated at the end of the operation. The patient had stable vital signs and normal laboratory findings during the recovery period and the hemoglobin was 116 g/L. She was discharged six days after delivery without intervention-related complications. This case illustrates that temporary occlusion of the infrarenal abdominal aorta using balloon might be a safe and effective treatment option for patients with placenta previa complicated with placenta percreta, who were at high

  11. Initial Experience and Feasibility of the New Low-Profile Stingray Catheter as Part of the Antegrade Dissection and Re-Entry Revascularization Strategy for Coronary Chronic Total Occlusions

    PubMed Central

    Maeremans, Joren; Palmers, Pieter-Jan; Dens, Joseph

    2017-01-01

    Case series Patient: Male, 77 • Male, 57 • Male, 73 Final Diagnosis: Coronary chronic total occlusion Symptoms: Angina pectoris Medication: — Clinical Procedure: Percutaneous coronary intervention of coronary chronic total occlusions Specialty: Cardiology Objective: Unusual setting of medical care Background: During antegrade dissection re-entry (ADR) of chronic total occlusions (CTO), the first-generation Stingray catheter requires the use of large-bore guides (sheathless 7.5 Fr or 8 Fr), which increases the risk for access site-related complications and compromises radial approaches. Smaller guiding sizes necessitate long guidewires (e.g., 300 cm) or guidewire extensions for catheter advancement or removal. However, friction between guides and the Stingray catheter can result in unstable guidewire position or unintentional removal. Furthermore, failure to deliver the catheter at the distal re-entry zone is a common problem. To overcome issues of deliverability and reduce the need for pre-dilatations, with its inherent risk of creating subintimal hematomas, the Stingray low-profile (LP) balloon catheter was developed. Case Report: We describe 3 cases of successful application of the novel Stingray LP catheter during ADR. In all cases, 7 Fr guiding catheters were successfully used in combination with the device. The lower profile facilitated a good exchange and delivery of the device, without the need for balloon pre-dilatations in 2 cases. This resulted in a limited subintimal plane, enabling a smooth puncture into the true lumen. One case presented with extreme levels of calcification and tortuosity, resulting in a high degree of friction, despite the lower catheter profile. No in-hospital coronary or access site-related complications occurred. Conclusions: This case report illustrates the feasibility of the Stingray LP catheter for the treatment of CTOs via the ADR technique. The lower profile of the catheter potentially increases the deliverability

  12. The in vitro interactions between serum lipoproteins and proteoglycans of the neointima of rabbit aorta after a single balloon catheter injury.

    PubMed

    Alavi, M Z; Richardson, M; Moore, S

    1989-02-01

    The effect of injury-induced alterations in the aortic neointimal proteoglycans on their binding with homologous serum lipoproteins was examined. Proteoglycans of the aortic intimal-medial tissues of rabbits that had undergone denudation with a balloon catheter 12 weeks earlier were isolated after homogenization of the tissues in 0.33 M sucrose, ultracentrifugation and subsequently by gel-exclusion chromatography. Lipoproteins from the plasma of healthy donors were prepared by sequential, ultracentrifugal floatation after density adjustment with KBr. To study the interactions, aliquots of electrophoretically pure very low-density lipoproteins (VLDL, d less than 1.006 g/ml), low-density lipoproteins (LDL, d = 1.019-1.063 g/ml), or high-density lipoproteins (HDL, d = 1.210 g/ml) were incubated with proteoglycans in the presence of Ca++ and Mg++ at 4 C. The amount of cholesterol found in the resulting pellet was measured as a marker of the binding capacity of the proteoglycans. Among lipoprotein fractions both VLDL and LDL showed strong binding with proteoglycans, whereas no appreciable binding was observed when incubation experiments were done with HDL. There were significant differences in the lipoprotein binding capacity of proteoglycan of control and injured animals, indicating that injury induced changes in proteoglycan composition exert profound influences on their ionic interactions.

  13. Use of the Ascent balloon for a 2-in-1 remodeling technique: feasibility and initial experience: case report.

    PubMed

    Clarençon, Frédéric; Pérot, Guillaume; Biondi, Alessandra; Di Maria, Federico; Szatmary, Zoltan; Chiras, Jacques; Sourour, Nader

    2012-03-01

    To present the feasibility of using the Ascent balloon, a new double-lumen remodeling balloon, for a new 2-in-1 technique allowing coiling through the lumen of the balloon without the use of an additional coiling microcatheter. Remodeling technique had enlarged the indications for endovascular treatment of intracranial aneurysm. Nevertheless, one of the limitations of this technique is that it requires using 2 devices in the same parent artery. A 55-year-old woman presented with a 7.7 × 4.5-mm incidental anterior communicating artery aneurysm. Only 1 A1 segment (left side) was patent on the cerebral angiogram. A 6F Fargo Max guiding catheter was positioned in the left petrous internal carotid artery. The Ascent balloon was placed in front of the neck of the aneurysm after navigation on a Traxcess 0.014-in guidewire. Coiling of the aneurysm sac was performed via 1 lumen of the device under iterative inflations of the balloon through the second lumen. This new 2-in-1 technique using a sole remodeling balloon without an additional coiling microcatheter is very promising, especially in cases of a small-caliber parent artery.

  14. A successful retrograde re-entry at aorta using the Outback LTD catheter for a bilateral common iliac artery occlusion.

    PubMed

    Kim, Tae-Hoon; Ahn, Ji-Hun; Kim, Do-Hoi

    2013-05-01

    The Outback LTD re-entry catheter system has become a valuable tool for peripheral intervention and it has been widely used for variable peripheral chronic total occlusion (CTO). However, its use in the setting of the aorta was restricted because of concerns of bleeding risks resulting from re-entry puncture or ballooning. This report presents a case of successful re-entry using the Outback LTD Re-Entry Catheter (Cordis, Bridgewater, New Jersy) at the aorta in a patient with bilateral common iliac artery occlusion. Copyright © 2012 Wiley Periodicals, Inc.

  15. [Prevention of intrauterine adhesion with auto-crosslinked hyaluronic acid gel: a prospective, randomized, controlled clinical study].

    PubMed

    Xiao, Songshu; Wan, Yajun; Zou, Fangjun; Ye, Mingzhu; Deng, Henan; Ma, Jiezhi; Wei, Yingying; Tan, Chen; Xue, Min

    2015-01-01

    To evaluate the efficacy and safety of auto-crosslinked hyaluronic acid (HA) gel for preventing intrauterine adhesion (IUA) after hysteroscopic adhesiolysis. A prospective, randomized, double blinded and controlled clinical trial (level I) was performed. According to American Fertility Society (AFS) scoring system, 120 patients (treatment group: 60 cases, control group: 60 cases) with moderate to severe IUA were enrolled. Upon completion of adhesiolysis, a Foley balloon catheter was first introduced into the uterine cavity and then 3 ml of auto-crosslinked HA gel for patients in the treatment group; patients in the control group, however, only received Foley balloon catheter. Second-look hysteroscopic examination was performed to all patients at 3 months postoperatively for evaluation of IUA. Primary endpoint was the reduction rate of IUA at 3 months after surgery. The secondary endpoints include total AFS score, score of each individual AFS category. At 3 months after surgery, auto-crosslinked HA gel resulted in significantly higher effective rate for reduction of adhesion, the effective rate were 76% (42/55) and 48% (27/56) respectively (P = 0.000 9); the total AFS score of treatment group was 2.1 ± 1.1, and significantly lower than that of control group (3.7 ± 2.5, P = 0.000 8). Application of auto-crosslinked HA gel after surgery significantly enhanced the improvement for each individual patient with regard to their adhesive type and menstrual pattern (P = 0.037 8, P = 0.000 4). The treatment group had significantly lower proportion of patients with moderate to severe adhesive stages than that of control group [13% (7/55) versus 38% (21/56), P = 0.000 6]. No adverse events and complications were observed. Auto-crosslinked HA gel coule be able to reduce IUA, decrease adhesion severity, and improve menopause postoperatively. This absorbable auto-crosslinked HA gel is proposed as a barrier for preventing IUA after intrauterine procedures.

  16. Surgical treatment for Ellis type 3 coronary perforation during percutaneous catheter intervention.

    PubMed

    Totsugawa, Toshinori; Kuinose, Masahiko; Yoshitaka, Hidenori; Katayama, Keijiro; Tsushima, Yoshimasa; Ishida, Atsuhisa; Chikazawa, Genta; Hiraoka, Arudo

    2012-01-01

    Coronary perforation (CP) is a rare, but sometimes lethal, complication of percutaneous catheter intervention (PCI). We reviewed surgically-treated cases of type 3 CP during PCI. From 2007 to 2010, 5 patients underwent surgical repair for type 3 CP (3 men, 2 women; mean age, 74 years). The mean number of diseased coronary branches was 2.6 and the mean SYNTAX score was 45. The target lesions were the left anterior descending artery in 4 cases and the right coronary artery in 1 case. Types of American Heart Association/American College of Cardiology classification were type B2 in only one case and type C in 4 cases. The causes of perforation were balloon inflation in 4 patients and rotational atherectomy in 1 patient. The in-hospital mortality rate was 20%. In the cases of CP associated with balloon inflation, coronary lacerations were so severe that re-bleeding occurred even if the covered stent could temporarily achieve hemostasis, and percutaneous cardiopulmonary support and emergency surgery were required. CP induced by balloon inflation tends to result in a serious condition compared with rotablator-induced CP. Surgery should be immediately performed even after covered stent implantation if there is any possibility of re-bleeding in the case of balloon-induced type 3 CP.

  17. Intra-Aortic Balloon Pump Malposition Reduces Visceral Artery Perfusion in an Acute Animal Model.

    PubMed

    Vondran, Maximilian; Rastan, Ardawan J; Tillmann, Eugen; Seeburger, Jörg; Schröter, Thomas; Dhein, Stefan; Bakhtiary, Farhad; Mohr, Friedrich-Wilhelm

    2016-04-01

    Visceral artery perfusion can be potentially affected by intra-aortic balloon pump (IABP) catheters. We utilized an animal model to quantify the acute impact of a low balloon position on mesenteric artery perfusion. In six pigs (78 ± 7 kg), a 30-cc IABP was placed in the descending aorta in a transfemoral procedure. The celiac artery (CA) and the cranial mesenteric artery (CMA) were surgically dissected. Transit time blood flow was measured for (i) baseline, (ii) 1:1 augmentation with the balloon proximal to the visceral arteries, and (iii) 1:1 augmentation with the balloon covering the visceral arteries. Blood flow in the CMA and CA was reduced by 17 and 24%, respectively, when the balloon compromised visceral arteries compared with a position above the visceral arteries (flow in mL/min: CMA: (i) 1281 ± 512, (ii) 1389 ± 287, (iii) 1064 ± 276, P < 0.05 for 3 vs. 1 and 3 vs. 2; CA: (i) 885 ± 370, (ii) 819 ± 297, (iii) 673 ± 315; P < 0.05 for 3 vs. 1). The covering of visceral arteries by an IABP balloon causes a significant reduction of visceral artery perfusion; thus, the positioning of this device during implantation is critical for obtaining a satisfactory outcome. Copyright © 2015 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  18. Long-term results from the Contura multilumen balloon breast brachytherapy catheter phase 4 registry trial.

    PubMed

    Cuttino, Laurie W; Arthur, Douglas W; Vicini, Frank; Todor, Dorin; Julian, Thomas; Mukhopadhyay, Nitai

    2014-12-01

    To describe the long-term outcomes from a completed, multi-institutional phase 4 registry trial using the Contura multilumen balloon (CMLB) breast brachytherapy catheter to deliver accelerated partial breast irradiation (APBI) in patients with early-stage breast cancer. Three hundred forty-two evaluable patients were enrolled by 23 institutions between January 2008 and February 2011. All patients received 34 Gy in 10 fractions, delivered twice daily. Rigorous target coverage and normal tissue dose constraints were observed. The median follow-up time was 36 months (range, 1-54 months). For the entire patient cohort of 342 patients, 10 patients experienced an ipsilateral breast tumor recurrence (IBTR). Eight of these IBTR were classified as true recurrences/marginal miss (TRMM), and 2 were elsewhere failures (EF). Local recurrence-free survival was 97.8% at 3 years. For the entire cohort, 88% of patients had good to excellent overall cosmesis. The overall incidence of infection was 8.5%. Symptomatic seroma was reported in only 4.4% of patients. A separate analysis was performed to determine whether improved outcomes would be observed for patients treated at high-volume centers with extensive brachytherapy experience. Three IBTR were observed in this cohort, only 1 of which was classified as a TRMM. Local recurrence-free survival at high-volume centers was 98.1% at 3 years. Overall cosmetic outcome and toxicity were superior in patients treated at high-volume centers. In these patients, 95% had good to excellent overall cosmesis. Infection was observed in only 2.9% of patients, and symptomatic seroma was reported in only 1.9%. Use of the CMLB for APBI delivery is associated with acceptable long-term local control and toxicity. Local recurrence-free survival was 97.8% at 3 years. Significant (grade 3) toxicity was uncommon, and no grade 4 toxicity was observed. Treatment at high-volume centers was associated with decreased late toxicity. Copyright © 2014 Elsevier Inc

  19. Long-Term Results From the Contura Multilumen Balloon Breast Brachytherapy Catheter Phase 4 Registry Trial

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cuttino, Laurie W., E-mail: lcuttino@mcvh-vcu.edu; Arthur, Douglas W.; Vicini, Frank

    2014-12-01

    Purpose: To describe the long-term outcomes from a completed, multi-institutional phase 4 registry trial using the Contura multilumen balloon (CMLB) breast brachytherapy catheter to deliver accelerated partial breast irradiation (APBI) in patients with early-stage breast cancer. Methods and Materials: Three hundred forty-two evaluable patients were enrolled by 23 institutions between January 2008 and February 2011. All patients received 34 Gy in 10 fractions, delivered twice daily. Rigorous target coverage and normal tissue dose constraints were observed. Results: The median follow-up time was 36 months (range, 1-54 months). For the entire patient cohort of 342 patients, 10 patients experienced an ipsilateral breast tumor recurrencemore » (IBTR). Eight of these IBTR were classified as true recurrences/marginal miss (TRMM), and 2 were elsewhere failures (EF). Local recurrence-free survival was 97.8% at 3 years. For the entire cohort, 88% of patients had good to excellent overall cosmesis. The overall incidence of infection was 8.5%. Symptomatic seroma was reported in only 4.4% of patients. A separate analysis was performed to determine whether improved outcomes would be observed for patients treated at high-volume centers with extensive brachytherapy experience. Three IBTR were observed in this cohort, only 1 of which was classified as a TRMM. Local recurrence-free survival at high-volume centers was 98.1% at 3 years. Overall cosmetic outcome and toxicity were superior in patients treated at high-volume centers. In these patients, 95% had good to excellent overall cosmesis. Infection was observed in only 2.9% of patients, and symptomatic seroma was reported in only 1.9%. Conclusion: Use of the CMLB for APBI delivery is associated with acceptable long-term local control and toxicity. Local recurrence-free survival was 97.8% at 3 years. Significant (grade 3) toxicity was uncommon, and no grade 4 toxicity was observed. Treatment at high-volume centers was

  20. Rheolytic thrombectomy with use of the AngioJet-F105 catheter: preclinical evaluation of safety.

    PubMed

    Sharafuddin, M J; Hicks, M E; Jenson, M L; Morris, J E; Drasler, W J; Wilson, G J

    1997-01-01

    A preclinical evaluation of the safety of the AngioJet-F105 rheolytic thrombectomy catheter. The AngioJet-F105 catheter uses multiple retrograde high-speed fluid jets impinging on a primary aspiration lumen to create a hydrodynamic recirculation vortex that traps and fragments adjacent thrombus, with simultaneous evacuation of the resulting debris through the aspiration lumen. The effect of the AngioJet on treated vessels was evaluated in 10 canines. Vascular integrity on histopathologic examination and endothelial coverage on scanning electron microscopic study were examined in 15 vessel segments treated with the AngioJet-F105 catheter, compared with four vessel segments subjected to the Fogarty balloon maneuver, and 10 untreated vessel segments. The size distribution of particulate debris, upstream and downstream, after thrombectomy was determined in a flow-circuit model simulating the superficial femoral artery. Aliquots from the downstream effluent were then injected into the renal arteries of two healthy canines. The device caused only minimal focal endothelial denudation and no significant deep injury. No significant difference in endothelial coverage occurred in AngioJet-treated vessel segments compared to untreated control vessels (mean +/- standard deviation: 88.0% +/- 7.9% vs 89.7% +/- 11.6%, P = .77). Vessels treated with the Fogarty balloon pullback maneuver had significantly less residual endothelial coverage (58.0% +/- 8.0%, P < .03). Particulate microemboli in the effluent of the flow model accounted for 12% of the initial thrombus volume (0% > 100 microm, 99.83% < or = 10 microm). Histopathologic evaluation of the four renal beds injected with the resulting debris demonstrated no signs of necrosis. A moderate transient increase in plasma-free hemoglobin occurred, with a mild corresponding decrease in hematocrit. The AngioJet-F105 catheter resulted in only mild and focal injury to the treated vessels. The vast majority of resulting particulate debris

  1. [Bed-side management of post-operative bleeding in transurethral resection of the prostate--hemostatic trial with thrombin solution injected into the resected cavity of the prostate].

    PubMed

    Hasegawa, S; Nakashima, J; Kimura, S

    1987-08-01

    To control post-operative bleeding from the resected cavity in transurethral resection of the prostate (TUR-P), 20,000 units of thrombin dissolved in 5-20 ml of physiological saline was injected into the cavity in one shot with a new type of 3-way Foley catheter. The catheter has two holes close to the balloon, and the holes provide outlets through which the solution is directly injected into the cavity. Out of 23 patients between 58 and 87 years old, 11 were given thrombin and 12 were control cases. In each case, urine blood volume (ml/hr) was determined before (a) and after (b) injection. The hemostatic effect was assessed with a "hemostatic index" of b/a. There was a statistically significant difference in the hemostatic indices between thrombin group and the control. (p less than 0.02) This new hemostatic method proved to be a very useful easy bed-side technique to control bleeding even in sudden bleeding after TUR-P. No serious side effects were found during the course of this study.

  2. Endoscopic balloon catheter dilatation via retrograde or static technique is safe and effective for cricopharyngeal dysfunction

    PubMed Central

    Chandrasekhara, Vinay; Koh, Joyce; Lattimer, Lakshmi; Dunbar, Kerry B; Ravich, William J; Clarke, John O

    2017-01-01

    AIM To evaluate the safety and efficacy of upper esophageal sphincter (UES) dilatation for cricopharyngeal (CP) dysfunction. To determine if: (1) indication for dilatation; or (2) technique of dilatation correlated with symptom improvement. METHODS All balloon dilatations performed at our institution from over a 3-year period were retrospectively analyzed for demographics, indication and dilatation site. All dilatations involving the UES underwent further review to determine efficacy, complications, and factors that predict success. Dilatation technique was separated into static (stationary balloon distention) and retrograde (brusque pull-back of a fully distended balloon across the UES). RESULTS Four hundred and eighty-eight dilatations were reviewed. Thirty-one patients were identified who underwent UES dilatation. Median age was 63 years (range 27-81) and 55% of patients were male. Indications included dysphagia (28 patients), globus sensation with evidence of UES dysfunction (2 patients) and obstruction to echocardiography probe with cricopharyngeal (CP) bar (1 patient). There was evidence of concurrent oropharyngeal dysfunction in 16 patients (52%) and a small Zenker’s diverticula (≤ 2 cm) in 7 patients (23%). Dilator size ranged from 15 mm to 20 mm. Of the 31 patients, 11 had dilatation of other esophageal segments concurrently with UES dilatation and 20 had UES dilatation alone. Follow-up was available for 24 patients for a median of 2.5 mo (interquartile range 1-10 mo), of whom 19 reported symptomatic improvement (79%). For patients undergoing UES dilatation alone, follow-up was available for 15 patients, 12 of whom reported improvement (80%). Nineteen patients underwent retrograde dilatation (84% response) while 5 patients had static dilatation (60% response); however, there was no significant difference in symptom improvement between the techniques (P = 0.5). Successful symptom resolution was also not significantly affected by dilator size

  3. Perioperative Internal Iliac Artery Balloon Occlusion, In the Setting of Placenta Accreta and Its Variants: The Role of the Interventional Radiologist.

    PubMed

    Petrov, David A; Karlberg, Benjamin; Singh, Kamalpreet; Hartman, Matthew; Mittal, Pardeep K

    2017-11-10

    Placenta accreta and its variants (increta and percreta) are conditions of abnormal placentation that are encountered with increasing frequency. The spectrum of placenta accreta (including placenta increta and percreta) involves an abnormal attachment of the placental chorionic villi to the uterine myometrium. This abnormal attachment leads to increased adherence of the placenta to the uterus and abnormal placental-uterine separation at the time of delivery. Placental invasion into, or through the myometrium is associated with increased postpartum morbidity and mortality as a result of uterine hemorrhage during and following cesarean section. A multidisciplinary clinical approach to the treatment of patients with placenta accreta is recommended by the American College of Obstetricians and Gynecologists. As potential members of an interdisciplinary team, interventional radiologists can perform prophylactic internal iliac arterial balloon occlusion as an adjunctive therapy for reducing potentially life-threatening postpartum hemorrhage. The procedure involves placement of a balloon catheter into the internal iliac or common iliac arteries bilaterally prior to cesarean section. Following delivery, and prior to placental separation, the catheter balloons are inflated with a pre-determined volume of saline leading to transient occlusion of the internal iliac arteries and reduced uterine blood flow. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. SU-E-T-297: Dosimetric Assessment of An Air-Filled Balloon Applicator in HDR Vaginal Cuff Brachytherapy Using the Monte Carlo Method

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jiang, H; Lee, Y; Pokhrel, D

    2015-06-15

    Purpose: As an alternative to cylindrical applicators, air inflated balloon applicators have been introduced into HDR vaginal cuff brachytherapy treatment to achieve sufficient dose to vagina mucosa as well as to spare rectum and bladder. In general, TG43 formulae based treatment planning systems do not take into account tissue inhomogeneity, and air in the balloon applicator can cause higher delivered dose to mucosa than treatment plan reported. We investigated dosimetric effect of air in balloon applicator using the Monte Carlo method. Methods: The thirteen-catheter Capri applicator with a Nucletron Ir-192 seed was modeled for various balloon diameters (2cm to 3.5cm)more » using the MCNP Monte Carlo code. Ir-192 seed was placed in both central and peripheral catheters to replicate real patient situations. Existence of charged particle equilibrium (CPE) with air balloon was evaluated by comparing kerma and dose at various distances (1mm to 70mm) from surface of air-filled applicator. Also mucosa dose by an air-filled applicator was compared with by a water-filled applicator to evaluate dosimetry accuracy of planning system without tissue inhomogeneity correction. Results: Beyond 1mm from air/tissue interface, the difference between kerma and dose was within 2%. CPE (or transient CPE) condition was deemed existent, and in this region no electron transport was necessary in Monte Carlo simulations. At 1mm or less, the deviation of dose from kerma became more apparent. Increase of dose to mucosa depended on diameter of air balloon. The increment of dose to mucosa was 2.5% and 4.3% on average for 2cm and 3.5cm applicators, respectively. Conclusion: After introduction of air balloon applicator, CPE fails only at the proximity of air/tissue interface. Although dose to mucosa is increased, there is no significant dosimetric difference (<5%) between air and water filled applicators. Tissue inhomogeneity correction is not necessary for air-filled applicators.« less

  5. Balloon Blocking Technique (BBT) for Superselective Catheterization of Inaccessible Arteries with Conventional and Modified Techniques

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Morishita, Hiroyuki, E-mail: hmorif@koto.kpu-m.ac.jp, E-mail: mori-h33@xa2.so-net.ne.jp; Takeuchi, Yoshito, E-mail: yotake62@qg8.so-net.ne.jp; Ito, Takaaki, E-mail: takaaki@koto.kpu-m.ac.jp

    2016-06-15

    PurposeThe purpose of the study was to retrospectively evaluate the efficacy and safety of the balloon blocking technique (BBT).Materials and MethodsThe BBT was performed in six patients (all males, mean 73.5 years) in whom superselective catheterization for transcatheter arterial embolization by the conventional microcatheter techniques had failed due to anatomical difficulty, including targeted arteries originating steeply or hooked from parent arteries. All BBT procedures were performed using Seldinger’s transfemoral method. Occlusive balloons were deployed and inflated at the distal side of the target artery branching site in the parent artery via transfemoral access. A microcatheter was delivered from a 5-F cathetermore » via another femoral access and was advanced over the microguidewire into the target artery, under balloon blockage of advancement of the microguidewire into non-target branches. After the balloon catheter was deflated and withdrawn, optimal interventions were performed through the microcatheter.ResultsAfter success of accessing the targeted artery by BBT, optimal interventions were accomplished in all patients with no complications other than vasovagal hypotension, which responded to nominal therapy.ConclusionThe BBT may be useful in superselective catheterization of inaccessible arteries due to anatomical difficulties.« less

  6. [Obstruction of the nasal passage caused by a balloon catheter in a calf].

    PubMed

    Rijkenhuizen, A B

    1993-01-01

    Decompression of the rumen as a supporting symptomatic therapy of recurrent bloat in calves and juvenile cattle is used regularly. The gas should be released for several days. This is facilitated by the use of a balloon stomach tube, which can be left in situ for up to five days. However, the use of this tube is not always without risks, which will be discussed on base of a patient.

  7. Ballooning Then...and Ballooning Now.

    ERIC Educational Resources Information Center

    Journal of Aerospace Education, 1978

    1978-01-01

    Describes the history of hot-air balloon travel, starting with its French origins and continuing through to the 1978 national championship. An address for Balloon Federation of America membership is included. (MA)

  8. Stenting for curved lesions using a novel curved balloon: Preliminary experimental study.

    PubMed

    Tomita, Hideshi; Higaki, Takashi; Kobayashi, Toshiki; Fujii, Takanari; Fujimoto, Kazuto

    2015-08-01

    Stenting may be a compelling approach to dilating curved lesions in congenital heart diseases. However, balloon-expandable stents, which are commonly used for congenital heart diseases, are usually deployed in a straight orientation. In this study, we evaluated the effect of stenting with a novel curved balloon considered to provide better conformability to the curved-angled lesion. In vitro experiments: A Palmaz Genesis(®) stent (Johnson & Johnson, Cordis Co, Bridgewater, NJ, USA) mounted on the Goku(®) curve (Tokai Medical Co. Nagoya, Japan) was dilated in vitro to observe directly the behavior of the stent and balloon assembly during expansion. Animal experiment: A short Express(®) Vascular SD (Boston Scientific Co, Marlborough, MA, USA) stent and a long Express(®) Vascular LD stent (Boston Scientific) mounted on the curved balloon were deployed in the curved vessel of a pig to observe the effect of stenting in vivo. In vitro experiments: Although the stent was dilated in a curved fashion, stent and balloon assembly also rotated conjointly during expansion of its curved portion. In the primary stenting of the short stent, the stent was dilated with rotation of the curved portion. The excised stent conformed to the curved vessel. As the long stent could not be negotiated across the mid-portion with the balloon in expansion when it started curving, the mid-portion of the stent failed to expand fully. Furthermore, the balloon, which became entangled with the stent strut, could not be retrieved even after complete deflation. This novel curved balloon catheter might be used for implantation of the short stent in a curved lesion; however, it should not be used for primary stenting of the long stent. Post-dilation to conform the stent to the angled vessel would be safer than primary stenting irrespective of stent length. Copyright © 2014 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.

  9. Effect of the positioning of a balloon valve in the aorta on coronary flow during aortic regurgitation.

    PubMed

    Antonatos, P G; Anthopoulos, L P; Kandyla, D D; Karras, A D; Moulopoulos, S D

    1984-07-01

    The coronary artery flow changes relative to the function of a catheter-mounted balloon valve used for relief of aortic regurgitation were studied in 10 mongrel dogs. Acute aortic regurgitation was produced by severing the aortic cusps with a long needle. Coronary flow was recorded from the left anterior descending coronary artery through an electromagnetic flowmeter. When the balloon was functioning within the cavity of the left ventricle there were no significant changes in the coronary flow and aortic pressure, except for a slight decrease in the aortic end-diastolic pressure. When it was functioning in the aortic ring the coronary flow increased 6.52 +/- 1.65 ml/min/100 gm of myocardium (p less than 0.001) and became predominantly diastolic. When it was functioning in the ascending aorta the coronary flow decreased 6.22 +/- 1.16 ml/min/100 gm of myocardium (p less than 0.001) and remained predominantly systolic. Finally, when the balloon was functioning in the thoracic aorta the coronary flow did not change significantly. With the balloon functioning in the aortic ring, ascending aorta, or thoracic aorta, there was a significant increase in the aortic end-diastolic pressure and decrease in the pulse pressure distal to the location of the balloon. It is concluded that the location of the balloon valve inserted for relief of aortic regurgitation influences the effect on coronary arterial flow.

  10. A novel model approach for esophageal burns in rats: A comparison of three methods.

    PubMed

    Kalkan, Yildiray; Tumkaya, Levent; Akdogan, Remzi Adnan; Yucel, Ahmet Fikret; Tomak, Yakup; Sehitoglu, İbrahim; Pergel, Ahmet; Kurt, Aysel

    2015-07-01

    Corrosive esophageal injury causes serious clinical problems. We aimed to create a new experimental esophageal burn model using a single catheter without a surgical procedure. We conducted the study with two groups of 12 male rats that fasted for 12 h before application. A modified Foley balloon catheter was inserted into the esophageal lumen. The control group was given 0.9% sodium chloride, while the experimental group was given 37.5% sodium hydroxide with the other part of the catheter. After 60s, esophagus was washed with distilled water. The killed rats were examined using histopathological methods after 28 days. In comparison with the histopathological changes experienced by the study groups, the control groups were observed to have no pathological changes. Basal cell degeneration, dermal edema, and a slight increase in the keratin layer and collagen density of submucosa due to stenosis were all observed in the group subjected to esophageal corrosion. A new burn model can thus, we believe, be created without the involvement of invasive laparoscopic surgery and general anesthesia. The burn in our experiment was formed in both the distal and proximal esophagus, as in other models; it can also be formed optionally in the entire esophagus. © The Author(s) 2013.

  11. Stunning and Right Ventricular Dysfunction Is Induced by Coronary Balloon Occlusion and Rapid Pacing in Humans: Insights From Right Ventricular Conductance Catheter Studies.

    PubMed

    Axell, Richard G; Giblett, Joel P; White, Paul A; Klein, Andrew; Hampton-Til, James; O'Sullivan, Michael; Braganza, Denise; Davies, William R; West, Nick E J; Densem, Cameron G; Hoole, Stephen P

    2017-06-06

    We sought to determine whether right ventricular stunning could be detected after supply (during coronary balloon occlusion [BO]) and supply/demand ischemia (induced by rapid pacing [RP] during transcatheter aortic valve replacement) in humans. Ten subjects with single-vessel right coronary artery disease undergoing percutaneous coronary intervention with normal ventricular function were studied in the BO group. Ten subjects undergoing transfemoral transcatheter aortic valve replacement were studied in the RP group. In both, a conductance catheter was placed into the right ventricle, and pressure volume loops were recorded at baseline and for intervals over 15 minutes after a low-pressure BO for 1 minute or a cumulative duration of RP for up to 1 minute. Ischemia-induced diastolic dysfunction was seen 1 minute after RP (end-diastolic pressure [mm Hg]: 8.1±4.2 versus 12.1±4.1, P <0.001) and BO (end-diastolic pressure [mm Hg]: 8.1 ± 4.0 versus 8.7±4.0, P =0.03). Impairment of systolic and diastolic function after BO remained at 15-minutes recovery (ejection fraction [%]: 55.7±9.0 versus 47.8±6.3, P <0.01; end-diastolic pressure [mm Hg]: 8.1±4.0 versus 9.2±3.9, P <0.01). Persistent diastolic dysfunction was also evident in the RP group at 15-minutes recovery (end-diastolic pressure [mm Hg]: 8.1±4.1 versus 9.9±4.4, P =0.03) and there was also sustained impairment of load-independent indices of systolic function at 15 minutes after RP (end-systolic elastance and ventriculo-arterial coupling [mm Hg/mL]: 1.25±0.31 versus 0.85±0.43, P <0.01). RP and right coronary artery balloon occlusion both cause ischemic right ventricular dysfunction with stunning observed later during the procedure. This may have intraoperative implications in patients without right ventricular functional reserve. © 2017 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.

  12. An Onyx tunnel: reconstructive transvenous balloon-assisted Onyx embolization for dural arteriovenous fistula of the transverse-sigmoid sinus.

    PubMed

    Kerolus, Mena G; Chung, Joonho; Munich, Stephen A; Matsuda, Yoshikazu; Okada, Hideo; Lopes, Demetrius K

    2017-11-17

    Transvenous embolization is an effective method for treating dural arteriovenous fistulas (DAVFs) of the transverse-sigmoid sinus (TSS). However, in cases of complicated DAVFs, it is difficult to preserve the patency of the dural sinus. The authors describe the technical details of a new reconstructive technique using transvenous balloon-assisted Onyx embolization as another treatment option in a patient with an extensive and complex DAVF of the left TSS. A microcatheter and compliant balloon catheter were navigated into the left internal jugular vein and placed at the distal end of the DAVF in the transverse sinus. The microcatheter was placed between the vessel wall of the TSS and the balloon. After the balloon was fully inflated, Onyx-18 was injected at the periphery of the balloon in a slow, controlled, progressive, stepwise manner; the balloon and microcatheter were simultaneously withdrawn toward the sigmoid sinus, with Onyx encompassing the entirety of the complex DAVF. The Onyx refluxed into multiple arterial feeders in a distal-to-proximal step-by-step manner, ultimately resulting in an Onyx tunnel. The final angiography study revealed complete obliteration of the DAVF and patency of the TSS. The Onyx tunnel, or reconstructive transvenous balloon-assisted Onyx embolization technique, may be an effective treatment option for large, complex DAVFs of the TSS. This technique may provide another option to facilitate the complete obliteration of the DAVF while preserving the functional sinus.

  13. Fibrin Sheath Angioplasty: A Technique to Prevent Superior Vena Cava Stenosis Secondary to Dialysis Catheters

    PubMed Central

    Hacker, Robert I.; Garcia, Lorena De Marco; Chawla, Ankur; Panetta, Thomas F.

    2012-01-01

    Fibrin sheaths are a heterogeneous matrix of cells and debris that form around catheters and are a known cause of central venous stenosis and catheter failure. A total of 50 cases of central venous catheter fibrin sheath angioplasty (FSA) after catheter removal or exchange are presented. A retrospective review of an outpatient office database identified 70 eligible patients over a 19-month period. After informed consent was obtained, the dialysis catheter exiting the skin was clamped, amputated, and a wire was inserted. The catheter was then removed and a 9-French sheath was inserted into the superior vena cava, a venogram was performed. If a fibrin sheath was present, angioplasty was performed using an 8 × 4 or 10 × 4 balloon along the entire length of the fibrin sheath. A completion venogram was performed to document obliteration of the sheath. During the study, 50 patients were diagnosed with a fibrin sheath, and 43 had no pre-existing central venous stenosis. After FSA, 39 of the 43 patient's (91%) central systems remained patent without the need for subsequent interventions; 3 patients (7%) developed subclavian stenoses requiring repeat angioplasty and stenting; 1 patent (2.3%) developed an occlusion requiring a reintervention. Seven patients with prior central stenosis required multiple angioplasties; five required stenting of their central lesions. Every patient had follow-up fistulograms to document long-term patency. We propose that FSA is a prudent and safe procedure that may help reduce the risk of central venous stenosis from fibrin sheaths due to central venous catheters. PMID:23997555

  14. Feasibility and Proposed Training Pathway for Austere Application of Resuscitative Balloon Occlusion of the Aorta.

    PubMed

    Ross, Elliot M; Redman, Theodore T

    Noncompressible junctional and truncal hemorrhage remains a significant cause of combat casualty death. Resuscitative endovascular balloon occlusion of the aorta (REBOA) is an effective treatment for many junctional and noncompressible hemorrhages. The current hospital standard for time of placement of REBOA is approximately 6 minutes. This study examined the training process and the ability of nonsurgical physicians to apply REBOA therapy in an austere field environment. This was a skill acquisition and feasibility study. The participants for this experiment were two board-certified military emergency medicine physicians with no prior endovascular surgery exposure. Both providers attended two nationally recognized REBOA courses for training. A perfused cadaver model was developed for the study. Each provider then performed REBOA during different phases of prehospital care. Time points were recorded for each procedure. There were 28 REBOA catheter placement attempts in 14 perfused cadaver models in the nonhospital setting: eight placements in a field setting, eight placements in a static ambulance, four placements in a moving ambulance, and eight placements inflight on a UH-60 aircraft. No statistically significant differences with regard to balloon inflation time were found between the two providers, the side where the catheter was placed, or individual cadaver models. Successful placement was accomplished in 85.7% of the models. Percutaneous access was successful 53.6% of the time. The overall average time for REBOA placement was 543 seconds (i.e., approximately 9 minutes; median, 439 seconds; 95% confidence interval [CI], 429-657) and the average placement time for percutaneous catheters was 376 seconds (i.e., 6.3 minutes; 95% CI, 311-44 seconds) versus those requiring vascular cutdown (821 seconds; 95% CI, 655-986). Importantly, the time from the decision to convert to open cutdown until REBOA placement was 455 seconds (95% CI, 285-625). This study demonstrated

  15. Efficacy and safety of catheter-based rheolytic and aspiration thrombectomy in children.

    PubMed

    Qureshi, Athar M; Petit, Christopher J; Crystal, Matthew A; Liou, Aimee; Khan, Asra; Justino, Henri

    2016-06-01

    Vascular thromboses are a significant cause of morbidity and mortality in children. Data in children regarding catheter-based rheolytic and aspiration thrombectomy systems are limited. We sought to review the safety and efficacy of catheter-based rheolytic and aspiration thrombectomy systems in children. Data of all children having undergone thrombectomy using specialized rheolytic or aspiration systems were reviewed. Thrombectomy was performed in 50 vessels in 21 patients, median age 1.9 months (8 days-18 yrs), median weight 4.3 (1.1-67.9) kg. Thrombectomy was performed using AngioJet in 16, Helix Clot Buster in 5, Fetch catheter in 8, Pronto catheter in 1, and a combination of other systems in 20 vessels (with AngioJet in 16). Thrombectomy was successful in 47/50 (94%) vessels in 18/21 (86%) patients with additional balloon/stent therapy or tPA administration performed in 16/18 (89%) of these patients. There were 2 (9.5%) major complications (both with AngioJet) consisting of asystole when thrombectomy was performed using activation times of >5 sec. At a median follow-up of 10 months (2 weeks-7 years), all 47 successfully treated vessels are patent, with 8/18 (44%) patients requiring reintervention with angioplasty/stent placement or repeat thrombectomy. Catheter-based thrombectomy systems are an important adjunctive tool in the treatment of children with thrombotic vessel occlusions. Significant hemodynamic compromise seen when using AngioJet may be minimized by using activation times of ≤5 sec. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  16. 78 FR 65511 - Death of Thomas S. Foley Former Speaker of the House of Representatives

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-10-31

    ... Vol. 78 Thursday, No. 211 October 31, 2013 Part IV The President Proclamation 9046--Death of Thomas S. Foley Former Speaker of the House of Representatives #0; #0; #0; Presidential Documents #0; #0...; #0; #0;Title 3-- #0;The President [[Page 65513

  17. Replacement of Dislodged Gastrostomy Tubes After Stoma Dilation in the Pediatric Emergency Department.

    PubMed

    Bhambani, Shiloni; Phan, Tammy H; Brown, Lance; Thorp, Andrea W

    2017-06-01

    A dislodged gastrostomy tube (GT) is a common complaint that requires evaluation in the pediatric emergency department (ED) and, on occasion, will require stoma dilation to successfully replace the GT. The objective of this study was to describe the frequency that stoma dilation is required, the success rate of replacement, complications encountered, and the techniques used to confirm placement of the GT after dilation. We conducted a retrospective medical record review of children 0-18 years who presented to the pediatric ED from February 2013 through February 2015 with a dislodged GT that required stoma dilation by pediatric emergency physicians with serially increasing Foley catheter sizes prior to successful placement of the GT. We reviewed a total of 302 encounters in 215 patients, with 97 (32%) of the encounters requiring stoma dilation prior to replacing a GT. The median amount of dilation was 2 French between the initial Foley catheter size and the final GT size. There was a single complication of a mal-positioned balloon that was identified at the index visit. No delayed complications were encountered. We performed confirmation of placement in all patients. The two most common forms of confirmation were aspiration of gastric contents (56/97 [58%]) followed by contrast radiograph in 39 (40%). The practice of serial dilation of a gastrostomy stoma site to allow successful replacement of a gastrostomy tube in pediatric patients who present to the ED with a dislodged gastrostomy tube is generally successful and without increased complication. All patients received at least one form of confirmation for appropriate GT placement with the most common being aspiration of gastric contents.

  18. Urinary catheters

    MedlinePlus

    ... drainage bag. The condom catheter must be changed every day. INTERMITTENT CATHETERS You would use an intermittent catheter ... and the catheter itself with soap and water every day. Also clean the area after every bowel movement ...

  19. Catheter-less robotic radical prostatectomy using a custom-made synchronous anastomotic splint and vesical urinary diversion device: report of the initial series and perioperative outcomes.

    PubMed

    Tewari, Ashutosh; Rao, Sandhya; Mandhani, Anil

    2008-09-01

    To study the feasibility of avoiding a urethral catheter after robotic radical prostatectomy by using suprapubic diversion with a urethral splint, as urethral catheterization is often a source of major discomfort and pain to the patient, and can cause more concern to the patient than the procedure; we present the outcomes of a pilot study. This pilot study involved 30 patients; in group 1 (the study group of 10 patients) we used a custom-made suprapubic catheter which provided a small anastomotic splint, multiple holes for drainage and the ability to retract the splint to give a voiding trial before removing the drainage device. Group 2 was a control group of 20 patients who had standard urethral catheterization with an 18 F Silastic Foley catheter. Demographic, intraoperative and outcome data were measured and analysed. Urethral symptoms were recorded using a specially developed questionnaire. The two groups were comparable in terms of age, serum prostate specific antigen level, body mass index, Gleason scores, tumour stage, operative duration, amount of bleeding, console times, anastomotic leakage and postoperative retention rates. The study group had significantly less penile shaft or tip pain and discomfort during walking or sleeping. No patient in either group had haematuria or clot retention requiring irrigation. Urethral catheter-less robotic radical prostatectomy is feasible. The advantages are decreased penile shaft and tip pain, and decreased patient discomfort and an earlier return of continence.

  20. A bulbar artery pseudoaneurysm following traumatic urethral catheterization.

    PubMed

    Bettez, Mathieu; Aubé, Melanie; Sherbiny, Mohamed El; Cabrera, Tatiana; Jednak, Roman

    2017-01-01

    Traumatic urethral catheterization may result in a number of serious complications. A rare occurrence is the development of a urethral pseudoaneurysm. We report the case of a 13-year-old male who required placement of a Foley catheter for an orthopedic surgical procedure. The Foley was misplaced in the bulbourethra, resulting in the development of a bulbar artery pseudoaneurysm. Profuse bleeding via the urethra was noted after removal of the catheter, and the patient experienced severe intermittent hematuria during the postoperative period. Cystoscopy revealed a pulsatile mass within the bulbourethra. Angiography confirmed a bulbar artery pseudoaneurysm, which was successfully embolized with resolution of bleeding.

  1. Usefulness of Corsair microcatheter to cross stent struts in bifurcation lesions.

    PubMed

    Fujimoto, Yoshihide; Iwata, Yo; Yamamoto, Masashi; Kobayashi, Yoshio

    2014-01-01

    Side branch compromise after stenting in bifurcation lesions is a matter of concern. It may happen that even low-profile balloon catheters do not cross stent struts after rewiring. The Corsair catheter is a hybrid catheter that has features of a microcatheter and a support catheter. The present study evaluated usefulness of the Corsair catheter to facilitate advancing a low-profile balloon catheter through stent struts in bifurcation lesions. After rewiring, low-profile balloon catheters failed to cross stent struts of 29 bifurcation lesions. The Corsair microcatheter successfully crossed stent struts in all lesions except one (97 %) where a stent was implanted to treat in-stent restenosis (stent-in-stent). Low-profile balloon catheters were able to advance into the side branch of all bifurcation lesions where the Corsair microcatheter crossed stent struts. In conclusion, the Corsair microcatheter may be utilized if low-profile balloon catheters are unable to cross stent struts in bifurcation lesions.

  2. Management of Bartholin's cyst and abscess using the Word catheter: implementation, recurrence rates and costs.

    PubMed

    Reif, Philipp; Ulrich, Daniela; Bjelic-Radisic, Vesna; Häusler, Martin; Schnedl-Lamprecht, Elke; Tamussino, Karl

    2015-07-01

    Bartholin's cysts and abscesses occur in about 2% of women. None of the surgical or conservative treatment approaches have been proven to be superior. The Word catheter is an outpatient treatment option, but little is known about aspects of implementing this therapy in an office setting. The present study's focus is on recurrence rates and organizational requirements of implementing outpatient treatment of Bartholin's cyst and abscess and compares costs of Word catheter treatment and marsupialization. Between March 2013 and May 2014 30 women were included in the study. We measured time consumed for treatment and follow-up and analyzed costs using the Word catheter and marsupialization under general anesthesia. We also assessed the ease of use of the Word catheter for application and removal using a standardized visual analog scale (VAS 1-10). Word catheter treatment was successful in 26/30 cases (87%). Balloon loss before the end of the 4-week treatment period occurred in 11/26 cases with a mean residence time of 19.1 (±10.0) days. None of the patients with early catheter loss developed recurrent cyst or abscess. Recurrence occurred in 1/26 cases (3.8%). Difficulty-score of application was 2 [1-10] and of removal 1 [1], respectively. Costs were € 216 for the treatment in the clinic as compared with € 1584/€ 1282 for surgical marsupialization with a one-night stay or daycare clinic, respectively. The present study indicates that the Word catheter is an easy to handle, low cost outpatient procedure with acceptable short-term recurrence rates. Treatment costs are seven times lower than for marsupialization. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  3. Hydrophilic Catheters

    PubMed Central

    2006-01-01

    Executive Summary Objective To review the evidence on the effectiveness of hydrophilic catheters for patients requiring intermittent catheterization. Clinical Need There are various reasons why a person would require catheterization, including surgery, urinary retention due to enlargement of the prostate, spinal cord injuries, or other physical disabilities. Urethral catheters are the most prevalent cause of nosocomial urinary tract infections, that is, those that start or occur in a hospital. A urinary tract infection (UTI) occurs when bacteria adheres to the opening of the urethra. Most infections arise from Escherichia coli, from the colon. The bacteria spread into the bladder, resulting in the development of an infection. The prevalence of UTIs varies with age and sex. There is a tenfold increase in incidence for females compared with males in childhood and throughout adult life until around 55 years, when the incidence of UTIs in men and women is equal, mostly as a consequence of prostatic problems in men. Investigators have reported that urethritis (inflammation of the urethra) is found in 2% to 19% of patients practising intermittent catheterization. The Technology Hydrophilic catheters have a polymer coating that binds o the surface of the catheter. When the polymer coating is submersed in water, it absorbs and binds the water to the catheter. The catheter surface becomes smooth and very slippery. This slippery surface remains intact upon insertion into the urethra and maintains lubrication through the length of the urethra. The hydrophilic coating is designed to reduce the friction, as the catheter is inserted with the intention of reducing the risk of urethral damage. It has been suggested that because the hydrophilic catheters do not require manual lubrication they are more sterile and thus less likely to cause infection. Most hydrophilic catheters are prepackaged in sterile water, or there is a pouch of sterile water that is broken and released into the

  4. Japanese Balloon Program

    NASA Astrophysics Data System (ADS)

    Yoshida, Tetsuya; Fuke, Hideyuki; Shoji, Yasuhiro; Iijima, Issei; Izutsu, Naoki; Kato, Yoichi; Matsuzaka, Yukihiko; Mizuta, Eiichi; Sato, Takatoshi; Tamura, Keisuke; Saito, Yoshitaka; Kakehashi, Yuya

    2012-07-01

    Institute of Space and Astronautical Science, Japan Aerospace Exploration Agency conducts domestic balloon campaigns at Taiki Aerospace Research Field (TARF) in Hokkaido since 2008. The ballooning at TARF becomes stable after four year operation. Because the field faces to the Pacific Ocean, heavy balloons and payloads can be launched safely using a very unique sliding launcher. Recoveries at the inshore along the Tokachi coast can be done very quickly and smoothly. Unfortunately, flight opportunities are recently limited due to unfriendly weather condition. Unstable Jet stream also prevents us to have so-called `boomerang flight' to achieve long flight duration more than several hours. Six balloon-borne experiments were carried out in 2010 and 2011. Three of them were demonstrations of challenges of space engineering, two were in-situ atmospheric observation, and one was the technical flight of new high-resolution γ-ray telescope. In addition to these flights, we carried out two launches for next generation balloons: one for Tawara-shaped superpressure balloon and the other for ultra-thin high-altitude balloon. In this paper, recent activities of the Japanese scientific balloon program will be introduced. On-going development of the balloon system will also be presented.

  5. Catheter enterostomy and patch repair of the abdominal wall for gastroschisis with intestinal atresia: report of a case.

    PubMed

    Ohno, Koichi; Nakamura, Tetsuro; Azuma, Takashi; Yoshida, Tatsuyuki; Yamada, Hiroto; Hayashi, Hiroaki; Masahata, Kazunori

    2009-01-01

    A male infant, weighing 2177 g, was born with the entire intestine protruding through a defect on the right side of the navel. Intestinal atresia, approximately 70 cm from the Treitz ligament, was also confirmed. Primary anastomosis and abdominal wall repair were impossible because of the intestinal dilation and thick peel, as well as the small abdominal cavity. Thus, we initially performed catheter enterostomy with a 14-F balloon catheter and patch repair of the abdominal wall, to enable the baby to be fed. Secondary anastomosis and abdominal wall repair was safely performed when the baby was 106 days old. The combination of catheter enterostomy and patch repair of the abdominal wall does not require dissection of the intestine and it can be safely performed in low-birth-weight babies. It also enables feeding and weight gain, and the overlying skin prevents contamination of the artificial sheet. We recommend this combination for neonates with both gastroschisis and intestinal atresia.

  6. Improvements in critical dosimetric endpoints using the Contura multilumen balloon breast brachytherapy catheter to deliver accelerated partial breast irradiation: preliminary dosimetric findings of a phase iv trial.

    PubMed

    Arthur, Douglas W; Vicini, Frank A; Todor, Dorin A; Julian, Thomas B; Lyden, Maureen R

    2011-01-01

    Dosimetric findings in patients treated with the Contura multilumen balloon (MLB) breast brachytherapy catheter to deliver accelerated partial breast irradiation (APBI) on a multi-institutional Phase IV registry trial are presented. Computed tomography-based three-dimensional planning with dose optimization was performed. For the trial, new ideal dosimetric goals included (1) ≥95% of the prescribed dose (PD) covering ≥90% of the target volume, (2) a maximum skin dose ≤125% of the PD, (3) maximum rib dose ≤145% of the PD, and (4) the V150 ≤50 cc and V200 ≤10 cc. The ability to concurrently achieve these dosimetric goals using the Contura MLB was analyzed. 144 cases were available for review. Using the MLB, all dosimetric criteria were met in 76% of cases. Evaluating dosimetric criteria individually, 92% and 89% of cases met skin and rib dose criteria, respectively. In 93% of cases, ideal target volume coverage goals were met, and in 99%, dose homogeneity criteria (V150 and V200) were satisfied. When skin thickness was ≥5 mm to <7 mm, the median skin dose was limited to 120.1% of the PD, and when skin thickness was <5 mm, the median skin dose was 124.2%. When rib distance was <5 mm, median rib dose was reduced to 136.5% of the PD. When skin thickness was <7 mm and distance to rib was <5 mm, median skin and rib doses were jointly limited to 120.6% and 142.1% of the PD, respectively. The Contura MLB catheter provided the means of achieving the imposed higher standard of dosimetric goals in the majority of clinical scenarios encountered. Copyright © 2011 Elsevier Inc. All rights reserved.

  7. Improvements in Critical Dosimetric Endpoints Using the Contura Multilumen Balloon Breast Brachytherapy Catheter to Deliver Accelerated Partial Breast Irradiation: Preliminary Dosimetric Findings of a Phase IV Trial

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Arthur, Douglas W., E-mail: darthur@mcvh-vcu.ed; Vicini, Frank A.; Todor, Dorin A.

    2011-01-01

    Purpose: Dosimetric findings in patients treated with the Contura multilumen balloon (MLB) breast brachytherapy catheter to deliver accelerated partial breast irradiation (APBI) on a multi-institutional Phase IV registry trial are presented. Methods and Materials: Computed tomography-based three-dimensional planning with dose optimization was performed. For the trial, new ideal dosimetric goals included (1) {>=}95% of the prescribed dose (PD) covering {>=}90% of the target volume, (2) a maximum skin dose {<=}125% of the PD, (3) maximum rib dose {<=}145% of the PD, and (4) the V150 {<=}50 cc and V200 {<=}10 cc. The ability to concurrently achieve these dosimetric goals usingmore » the Contura MLB was analyzed. Results: 144 cases were available for review. Using the MLB, all dosimetric criteria were met in 76% of cases. Evaluating dosimetric criteria individually, 92% and 89% of cases met skin and rib dose criteria, respectively. In 93% of cases, ideal target volume coverage goals were met, and in 99%, dose homogeneity criteria (V150 and V200) were satisfied. When skin thickness was {>=}5 mm to <7 mm, the median skin dose was limited to 120.1% of the PD, and when skin thickness was <5 mm, the median skin dose was 124.2%. When rib distance was <5 mm, median rib dose was reduced to 136.5% of the PD. When skin thickness was <7 mm and distance to rib was <5 mm, median skin and rib doses were jointly limited to 120.6% and 142.1% of the PD, respectively. Conclusion: The Contura MLB catheter provided the means of achieving the imposed higher standard of dosimetric goals in the majority of clinical scenarios encountered.« less

  8. Catheter interventions in the staged management of hypoplastic left heart syndrome.

    PubMed

    Reinhardt, Zdenka; De Giovanni, Joseph; Stickley, John; Bhole, Vinay K; Anderson, Benjamin; Murtuza, Bari; Mehta, Chetan; Miller, Paul; Dhillon, Rami; Stumper, Oliver

    2014-04-01

    To analyse the current practice and contribution of catheter interventions in the staged management of patients with hypoplastic left heart syndrome. This study is a retrospective case note review of 527 patients undergoing staged Norwood/Fontan palliation at a single centre between 1993 and 2010. Indications and type of catheter interventions were reviewed over a median follow-up period of 7.5 years. A staged Norwood/Fontan palliation for hypoplastic left heart syndrome was performed in 527 patients. The 30-day survival rate after individual stages was 76.5% at Stage I, 96.3% at Stage II, and 99.4% at Stage III. A total of 348 interventions were performed in 189 out of 527 patients. Freedom from catheter intervention in survivors was 58.2% before Stage II and 46.7% before Stage III. Kaplan-Meier freedom from intervention post Fontan completion was 55% at 10.8 years of follow-up. Post-stage I interventions were mostly directed to relieve aortic arch obstruction--84 balloon angioplasties--and augment pulmonary blood flow--15 right ventricle-to-pulmonary conduit interventions; post-Stage II interventions centred on augmenting size of the left pulmonary artery--73 procedures and abolishing systemic venous collaterals--32 procedures. After Stage III, the focus was on manipulating the size of the fenestration--42 interventions--and the left pulmonary artery -31 procedures. Interventional cardiac catheterisation constitutes an integral part in the staged palliative management of patients with hypoplastic left heart syndrome. Over one-third (37%) of patients undergoing staged palliation required catheter intervention over the follow-up period.

  9. The efficacy of pre-delivery prophylactic trans-catheter arterial balloon occlusion of bilateral internal iliac artery in patients with suspected placental adhesion.

    PubMed

    Cho, Yoon Jin; Oh, Yong Taek; Kim, Suk Young; Kim, Ju Young; Jung, Sun Young; Chon, Seung Joo; Kim, Jeong Ho; Byun, Sung Su

    2017-01-01

    Prophylactic trans-catheter arterial balloon occlusion (PTABO) before cesarean section of placenta previa totalis has been introduced to prevent massive hemorrhage. The purpose of this study is to evaluate the clinical usefulness of PTABO in cases of suspected placental adhesion and to examine antepartal risk factors and perinatal outcomes in women with placental adhesion. Between January 2012 and December 2015, 77 patients who had undergone ultrasonography for evaluation of placenta previa were enrolled in this study. Seventeen of these patients with suspected placental adhesion by ultrasonography and Pelvic MRI underwent PTABO before cesarean section and another 59 patients underwent cesarean section without PTABO. Antepartal risk factors and peripartum maternal and neonatal outcomes were compared between patients with PTABO and those without PTABO. More advanced maternal age, longer in gestational weeks at delivery, and more common previous cesarean section history were observed in the PTABO group. Placenta adhesion, abnormal Doppler findings, and frequency of transfusion were more common in the PTABO group. However there was no significant difference in estimated blood loss, hospital days, and neonatal outcome. It had occurred 3 cases of hysterectomy and 1 case of uterine artery embolization after cesarean section in the PTABO group. Close surveillance of antepartum risk factors for placental adhesion using ultrasonography and pelvic magnetic resonance imaging is important to prevention of massive hemorrhage during cesarean section. PTABO before cesarean section might result in reduced blood loss and requirement for transfusion during the operation.

  10. An Intelligent Catheter System Robotic Controlled Catheter System

    PubMed Central

    Negoro, M.; Tanimoto, M.; Arai, F.; Fukuda, T.; Fukasaku, K.; Takahashi, I.; Miyachi, S.

    2001-01-01

    Summary We have developed a novel catheter system, an intelligent catheter system, which is able to control a catheter by an externally-placed controller. This system has made from master-slave mechanism and has following three components; 1) a joy stick as a master (for operators) 2)a catheter controller as a slave (for a patient),3)a micro force sensor as a sensing device. This catheter tele-guiding system has abilities to perform intravascular procedures from the distant places. It may help to reduce the radiation exposures to the operators and also to help train young doctors. PMID:20663387

  11. Multimodality Intra-Arterial Imaging Assessment of the Vascular Trauma Induced by Balloon-Based and Nonballoon-Based Renal Denervation Systems.

    PubMed

    Karanasos, Antonios; Van Mieghem, Nicolas; Bergmann, Martin W; Hartman, Eline; Ligthart, Jurgen; van der Heide, Elco; Heeger, Christian-H; Ouhlous, Mohamed; Zijlstra, Felix; Regar, Evelyn; Daemen, Joost

    2015-07-01

    Renal denervation is a new treatment considered for several possible indications. As new systems are introduced, the incidence of acute renal artery wall injury with relation to the denervation method is unknown. We investigated the acute repercussion of renal denervation on the renal arteries of patients treated with balloon-based and nonballoon-based denervation systems by quantitative angiography, intravascular ultrasound, and optical coherence tomography (OCT). Twenty-five patients (50 renal arteries) underwent bilateral renal denervation with 5 different systems, 3 of which balloon-based (Paradise [n=5], Oneshot [n=6], and Vessix V2 [n=5)]) and 2 nonballoon-based (Symplicity [n=6] and EnligHTN [n=3]). Analysis included quantitative angiography and morphometric intravascular ultrasound measurements pre and post procedure and assessment of vascular trauma (dissection, edema, or thrombus) by OCT after denervation. A significant reduction in lumen size by quantitative angiography and intravascular ultrasound was observed in nonballoon denervation but not in balloon denervation. By postdenervation OCT, dissection was seen in 14 arteries (32.6%). The percentage of frames with dissection was higher in balloon-based denervation catheters. Thrombus and edema were detected in 35 (81.4%) and 32 (74.4%) arteries, respectively. In arteries treated with balloon-based denervation that had dissection by OCT, the balloon/artery ratio was higher (1.24 [1.17-1.32] versus 1.10 [1.04-1.18]; P<0.01). A varying extent of vascular injury was observed after renal denervation in all systems; however, different patterns were identified in balloon-based and in nonballoon-based denervation systems. In balloon denervation, the presence of dissections by OCT was associated with a higher balloon/artery ratio. © 2015 American Heart Association, Inc.

  12. Balloons and Science Kit.

    ERIC Educational Resources Information Center

    Balloon Council, Washington, DC.

    This document provides background information on balloons including: (1) the history of balloons; (2) balloon manufacturing; (3) biodegradability; (4) the fate of latex balloons; and (5) the effect of balloons on the rainforest and sea mammals. Also included as part of this instructional kit are four fun experiments that allow students to…

  13. Dextran sulfate as a drug delivery platform for drug‐coated balloons: Preparation, characterization, in vitro drug elution, and smooth muscle cell response

    PubMed Central

    Lamichhane, Sujan; Anderson, Jordan; Remund, Tyler; Kelly, Patrick

    2015-01-01

    Abstract Drug‐coated balloons (DCBs) have now emerged as a promising approach to treat peripheral artery disease. However, a significant amount of drug from the balloon surface is lost during balloon tracking and results in delivering only a subtherapeutic dose of drug at the diseased site. Hence, in this study, the use of dextran sulfate (DS) polymer was investigated as a platform to control the drug release from balloons. An antiproliferative drug, paclitaxel (PAT), was incorporated into DS films (PAT‐DS). The characterizations using SEM, FT‐IR, and DSC showed that the films prepared were smooth and homogenous with PAT molecularly dispersed in the bulk of DS matrix in amorphous form. An investigation on the interaction of smooth muscle cells (SMCs) with control‐DS and PAT‐DS films showed that both films inhibited SMC growth, with a superior inhibitory effect observed for PAT‐DS films. PAT‐DS coatings were then produced on balloon catheters. The integrity of coatings was well‐maintained when the balloons were either deflated or inflated. In this study, up to 2.2 µg/mm2 of PAT was loaded on the balloons using the DS platform. Drug elution studies showed that only 10 to 20% of the total PAT loaded was released from the PAT‐DS coated balloons during the typical time period of balloon tracking (1 min) and then ∼80% of the total PAT loaded was released during the typical time period of balloon inflation and treatment (from 1 min to 4 min). Thus, this study demonstrated the use of DS as a platform to control drug delivery from balloons. © 2015 The Authors Journal of Biomedical Materials Research Part B: Applied Biomaterials Published by Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 104B: 1416–1430, 2016. PMID:26227252

  14. Recent Developments in Balloon Support Instrumentation at TIFR Balloon Facility, Hyderabad.

    NASA Astrophysics Data System (ADS)

    Vasudevan, Rajagopalan

    2012-07-01

    The Balloon Facility of Tata Institute of Fundamental Research has been conducting stratospheric balloon flights regularly for various experiments in Space Astronomy and Atmospheric Sciences. A continuous improvement in Balloon flight Support instrumentation by the Control Instrumentation Group to keep in space with the growing complexities of the scientific payloads have contributed to the total success of balloon flights conducted recently. Recent improvements in display of Balloon position during balloon flight by showing on real time the balloon GPS position against Google TM maps is of immense help in selecting the right spot for payload landing and safe recovery . For further speeding up the payload recovery process, a new GPS-GSM payload system has been developed which gives SMS of the payload position information to the recovery team on their cell phones. On parallel footing, a new GPS- VHF system has been developed using GPS and Radio Modems for Balloon Tracking and also for obtaining the payload impact point. On the Telecommand side, a single board Telecommand/ Timer weighing less than 2 Kg has been specially developed for use in the mesosphere balloon test flight. The interference on the existing Short Range Telemetry System has been eliminated by introducing a Band Pass Filter and LNA in the Receiving system of the modules, thereby enhancing its reliability. In this paper , we present the details of the above mentioned developments.

  15. GHOST balloons around Antarctica

    NASA Technical Reports Server (NTRS)

    Stearns, Charles R.

    1988-01-01

    The GHOST balloon position as a function of time data shows that the atmospheric circulation around the Antarctic Continent at the 100 mb and 200 mb levels is complex. The GHOST balloons supposedly follow the horizontal trajectory of the air at the balloon level. The position of GHOST balloon 98Q for a three month period in 1968 is shown. The balloon moved to within 2 deg of the South Pole on 1 October 1968 and then by 9 December 1968 was 35 deg from the South Pole and close to its position on 1 September 1968. The balloon generally moved from west to east but on two occasions moved in the opposite direction for a few days. The latitude of GHOST balloons 98Q and 149Z which was at 200 mb is given. Both balloons tended to get closer to the South Pole in September and October. Other GHOST balloons at the same pressure and time period may not indicate similar behavior.

  16. Adventitial nab-rapamycin injection reduces porcine femoral artery luminal stenosis induced by balloon angioplasty via inhibition of medial proliferation and adventitial inflammation.

    PubMed

    Gasper, Warren J; Jimenez, Cynthia A; Walker, Joy; Conte, Michael S; Seward, Kirk; Owens, Christopher D

    2013-12-01

    Endovascular interventions on peripheral arteries are limited by high rates of restenosis. Our hypothesis was that adventitial injection of rapamycin nanoparticles would be safe and reduce luminal stenosis in a porcine femoral artery balloon angioplasty model. Eighteen juvenile male crossbred swine were included. Single-injury (40%-60% femoral artery balloon overstretch injury; n=2) and double-injury models (endothelial denudation injury 2 weeks before a 20%-30% overstretch injury; n=2) were compared. The double-injury model produced significantly more luminal stenosis at 28 days, P=0.002, and no difference in medial fibrosis or inflammation. Four pigs were randomized to the double-injury model and adventitial injection of saline (n=2) or 500 μg of nanoparticle albumin-bound rapamycin (nab-rapamycin; n=2) with an endovascular microinfusion catheter. There was 100% procedural success and no difference in endothelial regeneration. At 28 days, nab-rapamycin led to significant reductions in luminal stenosis, 17% (interquartile range, 12%-35%) versus 10% (interquartile range, 8.3%-14%), P=0.001, medial cell proliferation, P<0.001, and fibrosis, P<0.001. There were significantly fewer adventitial leukocytes at 3 days, P<0.001, but no difference at 28 days. Pharmacokinetic analysis (single-injury model) found rapamycin concentrations 1500× higher in perivascular tissues than in blood at 1 hour. Perivascular rapamycin persisted ≥8 days and was not detectable at 28 days. Adventitial nab-rapamycin injection was safe and significantly reduced luminal stenosis in a porcine femoral artery balloon angioplasty model. Observed reductions in early adventitial leukocyte infiltration and late medial cell proliferation and fibrosis suggest an immunosuppressive and antiproliferative mechanism. An intraluminal microinfusion catheter for adventitial injection represents an alternative to stent- or balloon-based local drug delivery.

  17. Robotic positioning of standard electrophysiology catheters: a novel approach to catheter robotics.

    PubMed

    Knight, Bradley; Ayers, Gregory M; Cohen, Todd J

    2008-05-01

    Robotic systems have been developed to manipulate and position electrophysiology (EP) catheters remotely. One limitation of existing systems is their requirement for specialized catheters or sheaths. We evaluated a system (Catheter Robotics Remote Catheter Manipulation System [RCMS], Catheter Robotics, Inc., Budd Lake, New Jersey) that manipulates conventional EP catheters placed through standard introducer sheaths. The remote controller functions much like the EP catheter handle, and the system permits repeated catheter disengagement for manual manipulation without requiring removal of the catheter from the body. This study tested the hypothesis that the RCMS would be able to safely and effectively position catheters at various intracardiac sites and obtain thresholds and electrograms similar to those obtained with manual catheter manipulation. Two identical 7 Fr catheters (Blazer II; Boston Scientific Corp., Natick, Massachusetts) were inserted into the right femoral veins of 6 mongrel dogs through separate, standard 7 Fr sheaths. The first catheter was manually placed at a right ventricular endocardial site. The second catheter handle was placed in the mating holder of the RCMS and moved to approximately the same site as the first catheter using the Catheter Robotics RCMS. The pacing threshold was determined for each catheter. This sequence was performed at 2 right atrial and 2 right ventricular sites. The distance between the manually and robotically placed catheters tips was measured, and pacing thresholds and His-bundle recordings were compared. The heart was inspected at necropsy for signs of cardiac perforation or injury. Compared to manual positioning, remote catheter placement produced the same pacing threshold at 7/24 sites, a lower threshold at 11/24 sites, and a higher threshold at only 6/24 sites (p > 0.05). The average distance between catheter tips was 0.46 +/- 0.32 cm (median 0.32, range 0.13-1.16 cm). There was no difference between right atrial

  18. High-risk Trans-Catheter Aortic Valve Replacement in a Failed Freestyle Valve with Low Coronary Height: A Case Report.

    PubMed

    Karimi, Ashkan; Pourafshar, Negiin; Dibu, George; Beaver, Thomas M; Bavry, Anthony A

    2017-06-01

    A 55-year-old male with a history of two prior cardiac surgeries presented with decompensated heart failure due to severe bioprosthetic aortic valve insufficiency. A third operation was viewed prohibitively high risk and valve-in-valve trans-catheter aortic valve replacement was considered. There were however several high-risk features and technically challenging aspects including low coronary ostia height, poor visualization of the aortic sinuses, and difficulty in identification of the coplanar view due to severe aortic insufficiency, and a highly mobile aortic valve mass. After meticulous peri-procedural planning, trans-catheter aortic valve replacement was carried out with a SAPIEN 3 balloon-expandable valve without any complication. Strategies undertaken to navigate the technically challenging aspects of the case are discussed.

  19. Acute control of pulmonary regurgitation with a balloon "valve". An experimental investigation.

    PubMed

    Siwek, L G; Applebaum, R E; Jones, M; Clark, R E

    1985-09-01

    Operations for certain congenital cardiac lesions can produce pulmonary regurgitation. Pulmonary regurgitation contributes to right ventricular dysfunction, which may cause early postoperative morbidity and mortality. To ameliorate the problems of pulmonary regurgitation during the early postoperative period, we evaluated a method for its acute control. Complete pulmonary valvectomy was performed utilizing inflow occlusion in eight sheep. A catheter with a 15 ml spherical balloon was positioned in the pulmonary arterial trunk; its inflation and deflation were regulated by an intra-aortic balloon pump unit. Blood flow from the pulmonary arterial trunk and forward and regurgitant fraction were determined from electromagnetic flow transducer recordings. The regurgitant fraction with uncontrolled pulmonary regurgitation was 38% +/- 3% (forward flow = 42 +/- 5 ml/beat and regurgitant flow = 16 +/- 2 ml/beat). Inflation of the balloon during diastole was timed to completely eliminate pulmonary regurgitation. This balloon control of pulmonary regurgitation increased pulmonary arterial diastolic pressure from 12 +/- 1 to 17 +/- 1 mm Hg (p less than 0.0001) and decreased pulmonary arterial systolic pressure from 31 +/- 3 to 27 +/- 1 mm Hg (p = 0.06). Pulmonary arterial pulse pressure decreased from 19 +/- 3 to 9 +/- 1 mm Hg (p less than 0.003). Elimination of pulmonary regurgitation decreased right ventricular stroke volume (25 +/- 3 versus 42 +/- 5 ml/beat, p less than 0.0002) and resulted in a 46% reduction in right ventricular stroke work (5.0 +/- 0.6 versus 9.4 +/- 1.0 gm-m/beat, p less than 0.001) with no change in net forward pulmonary artery flow. Thus, acute pulmonary regurgitation can be controlled and this control improves overall hemodynamic status and decreases right ventricular work.

  20. Histological and morphometric analyses for rat carotid balloon injury model.

    PubMed

    Tulis, David A

    2007-01-01

    Experiments aimed at analyzing the response of blood vessels to mechanical injury and ensuing remodeling responses often employ the highly characterized carotid artery balloon injury model in laboratory rats. This approach utilizes luminal insertion of a balloon embolectomy catheter into the common carotid artery with inflation and withdrawal resulting in an injury characterized by vascular endothelial cell (EC) denudation and medial wall distension. The adaptive response to this injury is typified by robust vascular smooth muscle cell (SMC) replication and migration, SMC apoptosis and necrosis, enhanced synthesis and deposition of extracellular matrix (ECM) components, partial vascular EC regeneration from the border zones, luminal narrowing, and establishment of a neointima in time-dependent fashion. Evaluation of these adaptive responses to blood vessel injury can include acute and longer term qualitative and quantitative measures including expression analyses, activity assays, immunostaining for a plethora of factors and signals, and morphometry of neointima formation and gross mural remodeling. This chapter presents a logical continuation of Chapter 1 that offers details for performing the rat carotid artery balloon injury model in a standard laboratory setting by providing commonly used protocols for performing histological and morphometric analyses in such studies. Moreover, procedures, caveats, and considerations included in this chapter are highly relevant for alternative animal vascular physiology/pathophysiology studies and in particular those related to mechanisms of vascular injury and repair. Included in this chapter are specifics for in situ perfusion-fixation, tissue harvesting and processing for both snap-frozen and paraffin-embedded protocols, specimen embedding and sectioning, slide preparation, several standard histological staining steps, and routine morphological assessment.

  1. Catheter indwell time and phlebitis development during peripheral intravenous catheter administration.

    PubMed

    Pasalioglu, Kadriye Burcu; Kaya, Hatice

    2014-07-01

    Intravenous catheters have been indispensable tools of modern medicine. Although intravenous applications can be used for a multitude of purposes, these applications may cause complications, some of which have serious effects. Of these complications, the most commonly observed is phlebitis. This study was conducted to determine the effect of catheter indwell time on phlebitis development during peripheral intravenous catheter administration. This study determined the effect of catheter indwell time on phlebitis development during peripheral intravenous catheter administration. The study included a total of 103 individuals who were administered 439 catheters and satisfied the study enrollment criteria at one infectious diseases clinic in Istanbul/Turkey. Data were compiled from Patient Information Forms, Peripheral Intravenous Catheter and Therapy Information Forms, reported grades based on the Visual Infusion Phlebitis Assessment Scale, and Peripheral Intravenous Catheter Nurse Observation Forms. The data were analyzed using SPSS. Results : The mean patient age was 53.75±15.54 (standard deviation) years, and 59.2% of the study participants were men. Phlebitis was detected in 41.2% of peripheral intravenous catheters, and the rate decreased with increased catheter indwell time. Analyses showed that catheter indwell time, antibiotic usage, sex, and catheterization sites were significantly associated with development of phlebitis. The results of this study show that catheters can be used for longer periods of time when administered under optimal conditions and with appropriate surveillance.

  2. Drug-Coated Balloon Angioplasty: A Novel Treatment for Pulmonary Artery In-Stent Stenosis in a Patient with Williams Syndrome.

    PubMed

    Cohen, Jennifer L; Glickstein, Julie S; Crystal, Matthew A

    2017-12-01

    A 20-month-old boy with Williams syndrome had undergone multiple surgical and catheter-based interventions for resistant peripheral pulmonary arterial stenoses with eventual bilateral stent placement and conventional balloon angioplasty. He persistently developed suprasystemic right ventricular (RV) pressure. Angioplasty with a drug-coated balloon (DCB) was performed for in-stent restenosis and to remodel his distal pulmonary vessels bilaterally. This resulted in immediate improvement in the in-stent stenosis and resultant decrease in RV pressure. Follow-up catheterization two months later continued to show long-lasting improvement in the in-stent stenosis. We hypothesize that the anti-proliferative effects of DCBs may be of benefit in the arteriopathy associated with Williams syndrome. We report this as a novel use of a DCB in the pulmonary arterial circulation in a patient with Williams syndrome.

  3. Ballooning Comes of Age: Make Your Own Balloon.

    ERIC Educational Resources Information Center

    Eckford, Jim

    1983-01-01

    Provides instructions for building a working model of a hot-air balloon, offering suggestions for a successful flight. Indicates that children can be involved in the projects, for example, by filling in colors in the panels of a balloon drawing. (JN)

  4. Antimicrobial-impregnated catheters for the prevention of catheter-related bloodstream infections.

    PubMed

    Lorente, Leonardo

    2016-05-04

    Central venous catheters are commonly used in critically ill patients. Such catheterization may entail mechanical and infectious complications. The interest in catheter-related infection lies in the morbidity, mortality and costs that it involved. Numerous contributions have been made in the prevention of catheter-related infection and the current review focuses on the possible current role of antimicrobial impregnated catheters to reduce catheter-related bloodstream infections (CRBSI). There is evidence that the use of chlorhexidine-silver sulfadiazine (CHSS), rifampicin-minocycline, or rifampicin-miconazol impregnated catheters reduce the incidence of CRBSI and costs. In addition, there are some clinical circumstances associated with higher risk of CRBSI, such as the venous catheter access and the presence of tracheostomy. Current guidelines for the prevention of CRBSI recommended the use of a CHSS or rifampicin-minocycline impregnated catheter in patients whose catheter is expected to remain in place > 5 d and if the CRBSI rate has not decreased after implementation of a comprehensive strategy to reduce it.

  5. Antimicrobial-impregnated catheters for the prevention of catheter-related bloodstream infections

    PubMed Central

    Lorente, Leonardo

    2016-01-01

    Central venous catheters are commonly used in critically ill patients. Such catheterization may entail mechanical and infectious complications. The interest in catheter-related infection lies in the morbidity, mortality and costs that it involved. Numerous contributions have been made in the prevention of catheter-related infection and the current review focuses on the possible current role of antimicrobial impregnated catheters to reduce catheter-related bloodstream infections (CRBSI). There is evidence that the use of chlorhexidine-silver sulfadiazine (CHSS), rifampicin-minocycline, or rifampicin-miconazol impregnated catheters reduce the incidence of CRBSI and costs. In addition, there are some clinical circumstances associated with higher risk of CRBSI, such as the venous catheter access and the presence of tracheostomy. Current guidelines for the prevention of CRBSI recommended the use of a CHSS or rifampicin-minocycline impregnated catheter in patients whose catheter is expected to remain in place > 5 d and if the CRBSI rate has not decreased after implementation of a comprehensive strategy to reduce it. PMID:27152256

  6. Energy from solar balloons

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Grena, Roberto

    2010-04-15

    Solar balloons are hot air balloons in which the air is heated directly by the sun, by means of a black absorber. The lift force of a tethered solar balloon can be used to produce energy by activating a generator during the ascending motion of the balloon. The hot air is then discharged when the balloon reaches a predefined maximum height. A preliminary study is presented, along with an efficiency estimation and some considerations on possible realistic configurations. (author)

  7. Infraclavicular versus axillary nerve catheters: A retrospective comparison of early catheter failure rate.

    PubMed

    Quast, Michaela B; Sviggum, Hans P; Hanson, Andrew C; Stoike, David E; Martin, David P; Niesen, Adam D

    2018-05-01

    Continuous brachial plexus catheters are often used to decrease pain following elbow surgery. This investigation aimed to assess the rate of early failure of infraclavicular (IC) and axillary (AX) nerve catheters following elbow surgery. Retrospective study. Postoperative recovery unit and inpatient hospital floor. 328 patients who received IC or AX nerve catheters and underwent elbow surgery were identified by retrospective query of our institution's database. Data collected included unplanned catheter dislodgement, catheter replacement rate, postoperative pain scores, and opioid administration on postoperative day 1. Catheter failure was defined as unplanned dislodging within 24 h of placement or requirement for catheter replacement and evaluated using a covariate adjusted model. 119 IC catheters and 209 AX catheters were evaluated. There were 8 (6.7%) failed IC catheters versus 13 (6.2%) failed AX catheters. After adjusting for age, BMI, and gender there was no difference in catheter failure rate between IC and AX nerve catheters (p = 0.449). These results suggest that IC and AX nerve catheters do not differ in the rate of early catheter failure, despite differences in anatomic location and catheter placement techniques. Both techniques provided effective postoperative analgesia with median pain scores < 3/10 for patients following elbow surgery. Reasons other than rate of early catheter failure should dictate which approach is performed. Copyright © 2018. Published by Elsevier Inc.

  8. Catheter indwell time and phlebitis development during peripheral intravenous catheter administration

    PubMed Central

    Pasalioglu, Kadriye Burcu; Kaya, Hatice

    2014-01-01

    Objective: Intravenous catheters have been indispensable tools of modern medicine. Although intravenous applications can be used for a multitude of purposes, these applications may cause complications, some of which have serious effects. Of these complications, the most commonly observed is phlebitis. This study was conducted to determine the effect of catheter indwell time on phlebitis development during peripheral intravenous catheter administration. Methods: This study determined the effect of catheter indwell time on phlebitis development during peripheral intravenous catheter administration. The study included a total of 103 individuals who were administered 439 catheters and satisfied the study enrollment criteria at one infectious diseases clinic in Istanbul/Turkey. Data were compiled from Patient Information Forms, Peripheral Intravenous Catheter and Therapy Information Forms, reported grades based on the Visual Infusion Phlebitis Assessment Scale, and Peripheral Intravenous Catheter Nurse Observation Forms. The data were analyzed using SPSS. Results : The mean patient age was 53.75±15.54 (standard deviation) years, and 59.2% of the study participants were men. Phlebitis was detected in 41.2% of peripheral intravenous catheters, and the rate decreased with increased catheter indwell time. Analyses showed that catheter indwell time, antibiotic usage, sex, and catheterization sites were significantly associated with development of phlebitis. Conclusion: The results of this study show that catheters can be used for longer periods of time when administered under optimal conditions and with appropriate surveillance. PMID:25097505

  9. A prosthesis for banding the main pulmonary artery, capable of serial dilatation by balloon angioplasty.

    PubMed

    Vince, D J; Culham, J A

    1989-03-01

    A prosthesis constructed with a fatigued steel helix encased in a silicone rubber shield was used to band the main pulmonary artery in 10 dogs. After a mean duration of 138 days the banded site was dilated with a 20 mm diameter angioplasty catheter. This dilatation produced a mean increase of 44.3% in the cross-sectional area. A further mean increase of 2.2% in the cross-sectional area was measured 137 days after the dilatation. In five uncomplicated experiments a second dilatation was performed with a 23 mm diameter angioplasty catheter after a mean interval of 140 days. The second dilatation produced a further 21% increase in the cross-sectional area. In the five experiments in which two dilatations were performed, there was a total increase in the mean cross-sectional area of 94% produced 273 days after banding. This prosthesis maintains banding of the main pulmonary artery and can be serially dilated by balloon angioplasty.

  10. Coronary artery stent (image)

    MedlinePlus

    ... with a balloon catheter and expands when the balloon is inflated. The stent is then left there to help keep the artery open. ... with a balloon catheter and expands when the balloon is inflated. The stent is then left there to help keep the artery open.

  11. Ureteric catheterization via an ileal conduit: technique and retrieval of a JJ stent.

    PubMed

    Wah, T M; Kellett, M J

    2004-11-01

    Retrograde ureteric catheterization of a patient with an ileal conduit is difficult, because guide wires and catheters coil in the conduit. A modified loopogram, using a Foley catheter as a fulcrum through which catheters can be advanced to the ureteric anastomosis, is described. This technique was used to remove a JJ stent, which had been inserted previously across a stricture in one ureter, the stent crossing from one kidney to the other.

  12. Single balloon versus double balloon bipedicular kyphoplasty: a systematic review and meta-analysis.

    PubMed

    Jing, Zehao; Dong, Jianli; Li, Zhengwei; Nan, Feng

    2018-06-19

    Kyphoplasty has been widely used to treat vertebral compression fractures (VCFs). In standard procedure of kyphoplasty, two balloons were inserted into the vertebral body through bipedicular and inflated simultaneously, while using a single balloon two times is also a common method in clinic to lessen the financial burden of patients. However, the effect and safety of single balloon versus double balloon bipedicular kyphoplasty are still controversy. In this systematic review and meta-analysis, eligible studies were identified through a comprehensive literature search of PubMed, Cochrane library EMBASE, Web of Science, Wanfang, CNKI, VIP and CBM until January 1, 2018. Results from individual studies were pooled using a random or fixed effects model. Seven articles were included in the systematic review and five studies were consisted in meta-analysis. We observed no significant difference between single balloon and double balloon bipedicular kyphoplasty in visual analog scale (VAS), angle (kyphotic angle and Cobb angle), consumption (operation time, cement volume and volume of bleeding), vertebral height (anterior height, medium height and posterior height) and complications (cement leakage and new VCFs), while the cost of single balloon bipedicular kyphoplasty is lower than that of double balloon bipedicular kyphoplasty. The results of our meta-analysis also demonstrated that single balloon can significantly improve the VAS, angle and vertebral height of patients suffering from VCFs. This systematic review and meta-analysis collectively concludes that single balloon bipedicular kyphoplasty is as effective as double balloon bipedicular kyphoplasty in improving clinical symptoms, deformity and complications of VCFs but not so expensive. These slides can be retrieved under Electronic Supplementary Material.

  13. Balloon Design Software

    NASA Technical Reports Server (NTRS)

    Farley, Rodger

    2007-01-01

    PlanetaryBalloon Version 5.0 is a software package for the design of meridionally lobed planetary balloons. It operates in a Windows environment, and programming was done in Visual Basic 6. By including the effects of circular lobes with load tapes, skin mass, hoop and meridional stress, and elasticity in the structural elements, a more accurate balloon shape of practical construction can be determined as well as the room-temperature cut pattern for the gore shapes. The computer algorithm is formulated for sizing meridionally lobed balloons for any generalized atmosphere or planet. This also covers zero-pressure, over-pressure, and super-pressure balloons. Low circumferential loads with meridionally reinforced load tapes will produce shapes close to what are known as the "natural shape." The software allows for the design of constant angle, constant radius, or constant hoop stress balloons. It uses the desired payload capacity for given atmospheric conditions and determines the required volume, allowing users to design exactly to their requirements. The formulations are generalized to use any lift gas (or mixture of gases), any atmosphere, or any planet as described by the local acceleration of gravity. PlanetaryBalloon software has a comprehensive user manual that covers features ranging from, but not limited to, buoyancy and super-pressure, convenient design equations, shape formulation, and orthotropic stress/strain.

  14. Central venous stenosis in haemodialysis patients without a previous history of catheter placement.

    PubMed

    Oguzkurt, Levent; Tercan, Fahri; Yildirim, Sedat; Torun, Dilek

    2005-08-01

    To evaluate dialysis history, imaging findings and outcome of endovascular treatment in six patients with central venous stenosis without a history of previous catheter placement. Between April 2000 and June 2004, six (10%) of 57 haemodialysis patients had stenosis of a central vein without a previous central catheter placement. Venography findings and outcome of endovascular treatment in these six patients were retrospectively evaluated. Patients were three women (50%) and three men aged 32-60 years (mean age: 45 years) and all had massive arm swelling as the main complaint. The vascular accesses were located at the elbow in five patients and at the wrist in one patient. Three patients had stenosis of the left subclavian vein and three patients had stenosis of the left brachiocephalic vein. The mean duration of the vascular accesses from the time of creation was 25.1 months. Flow volumes of the vascular access were very high in four patients who had flow volume measurement. The mean flow volume was 2347 ml/min. One of three patients with brachiocephalic vein stenosis had compression of the vein by the brachiocephalic artery. All the lesions were first treated with balloon angioplasty and two patients required stent placement on long term. Number of interventions ranged from 1 to 4 (mean: 2.1). Symptoms resolved in five patients and improved in one patient who had a stent placed in the left BCV. Central venous stenosis in haemodialysis patients without a history of central venous catheterization tends to occur or be manifested in patients with a proximal permanent vascular access with high flow rates. Balloon angioplasty with or without stent placement offers good secondary patency rates in mid-term.

  15. Novel Software-Assisted Hemodynamic Evaluation of Pelvic Flow During Chemoperfusion of Pelvic Arteries for Bladder Cancer: Double- Versus Single-Balloon Technique

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yamamoto, Kiyohito, E-mail: rad105@poh.osaka-med.ac.jp; Yamamoto, Kazuhiro, E-mail: rad043@poh.osaka-med.ac.jp; Nakai, Go, E-mail: rad091@poh.osaka-med.ac.jp

    2016-06-15

    PurposeApproximately 83 % of patients with bladder cancer have achieved a complete response after undergoing a novel bladder preservation therapy involving balloon-occluded intra-arterial infusion chemotherapy (BOAI) using a four-lumen double-balloon catheter, known as the Osaka Medical College regimen. This study aimed to show the quantitative difference in hemodynamics of the bladder arteries using syngo iFlow (Siemens Healthcare, Erlangen, Germany), which provides an automatic tool for quantitative blood flow analysis between double BOAI (D-BOAI) and conventional single BOAI (S-BOAI).Materials and MethodsFifty patients were included. The catheters were introduced into both posterior trunks of the internal iliac arteries via contralateral femoral artery access.more » A side hole between the distal and proximal balloons was placed at the origin of each bladder artery to allow clear visualization of angiographic flow of the injected agent into the urinary bladder. Digital subtraction angiography was used during analysis with the syngo iFlow to evaluate the hemodynamics of the contrast medium in the pelvic arteries during BOAI. The comparative change in the amount of contrast medium in the bladder arteries between D-BOAI and S-BOAI was assessed using syngo iFlow.ResultsOne-hundred pelvic sides were analyzed. The amount of contrast medium in the bladder arteries using D-BOAI was more than twice that using S-BOAI (right, 3.03-fold; left, 2.81-fold).ConclusionThe amount of contrast medium in the bladder arteries using D-BOAI was higher than that using conventional S-BOAI. This may increase the anticancer drug concentration in the affected bladder, leading to a good clinical response.« less

  16. High-pressure balloon dilation in a dog with supravalvular aortic stenosis.

    PubMed

    Pinkos, A; Stauthammer, C; Rittenberg, R; Barncord, K

    2017-02-01

    A 6-month-old female intact Goldendoodle was presented for diagnostic work up of a grade IV/VI left basilar systolic heart murmur. An echocardiogram was performed and revealed a ridge of tissue distal to the aortic valve leaflets at the sinotubular junction causing an instantaneous pressure gradient of 62 mmHg across the supravalvular aortic stenosis and moderate concentric hypertrophy of the left ventricle. Intervention with a high-pressure balloon dilation catheter was pursued and significantly decreased the pressure gradient to 34 mmHg. No complications were encountered. The patient returned in 5 months for re-evaluation and static long-term reduction in the pressure gradient was noted. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Prospective short-term feasibility study of perioperative suprapubic catheters in laparoscopic colectomy.

    PubMed

    Nagao, Sayaka; Saida, Yoshihisa; Enomoto, Toshiyuki; Takahashi, Asako; Higuchi, Tadashi; Moriyama, Hodaka; Niituma, Toru; Watanabe, Manabu; Asai, Koji; Kusachi, Shinya

    2018-05-16

    Here we report a prospective study on whether a temporary suprapubic catheter (SPC) can be safely inserted as a substitute for transurethral balloon catheterization during laparoscopy-assisted colectomy. Our subjects included 52 cases who gave informed consent to have an SPC inserted. These subjects were selected from cases who underwent laparoscopy-assisted surgery for primary colorectal cancer from October 2014 to August 2015. An SPC was inserted into 45 of the original 52 cases. The median surgical duration was 220 min (range, 11-438 min), and the SPC insertion was performed at a median of 133 min (range, 9-384 min) after the start of surgery. Insertion required a median duration of 116 s. In one case (2.2%), the bladder was perforated by the paracentesis needle, and in two cases (4.4%), hematuria was observed at the time of insertion; however, surgery was completed without any incident in these three cases. Six of the remaining 42 cases (13.3%) demonstrated neither micturition desire nor independent urination on the day the catheter was clamped. In these cases, the clamp was released two to four times, and draining of an average of 586-mL urine, micturition desire, and independent urination were confirmed 2-4 days later. Transurethral balloon catheterization is a simple procedure that is commonly used on surgical patients, but it can cause pain, discomfort, and infection. In contrast, SPC insertion is a procedure that avoids crossing the urethra and its associated disadvantages. Here we were able to demonstrate that the procedure can be safely used in laparoscopic surgery patients. © 2018 Japan Society for Endoscopic Surgery, Asia Endosurgery Task Force and John Wiley & Sons Australia, Ltd.

  18. A single surgeon's experience with contact laser vaporization of the prostate

    NASA Astrophysics Data System (ADS)

    Mueller, Edward J.

    1995-05-01

    Herein, I report on my first 50 contact laser prostatectomies performed with the SLT Nd:YAG laser. The obstructed prostatic urethra is opened via contact laser vaporization of the obstructing adenoma. The average pre-op AUA symptom score was 22.9 (range 14 - 30). The average 3 month post-op AUA symptom score was 2.1 (range 0 -8). Eighteen of the patients had the foley catheter removed approximately 4 - 6 hours post-op and were discharged the same day. Thirty patients had the foley catheter removed the morning following surgery and were discharged. And two patients had the foley catheter removed the morning following surgery, but remained in the hospital for medical reasons unrelated to the TURP. Thus, 48 (96%) of the patients were discharged within 24 hours of admission. No patient had to be readmitted to the hospital for any reason. All patients were allowed to return to full activity within 24 hours of discharge. The average hospital cost for the 48 patients discharged within 24 hours was DOL4,694. This compares to the average hospital cost of an electrocautery TURP of DOL6-8000. In summary, contact laser TURP using the SLT Nd:YAG laser relived the symptoms of an obstructing prostate comparable to electrocautery TURP. However, these results were achieved with a much shorter hospitalization, a quicker return to full activity and at a lower cost.

  19. Balloon dilatation of benign and malignant esophageal strictures. Blind retrograde balloon dilatation.

    PubMed

    Graham, D Y; Smith, J L

    1985-06-01

    Balloon esophageal dilatation offers many theoretical advantages (safety, speed, and patient comfort) over dilatation with mercury-filled bougies or with the Eder-Puestow system. The authors used balloon dilators in 22 patients with dysphagia secondary to benign or malignant strictures. Dilatation was performed with fluoroscopic guidance, blindly, or by a combination of these techniques. For "blind" stricture dilatation, an Eder-Puestow spring-tipped guide wire is placed into the stomach using a fiberoptic endoscope. The distance from the incisor teeth to the stricture is measured, and the balloon shaft is marked to indicate when the middle of the balloon is within the stricture. Dilatation is then performed using the antegrade or, the preferred, retrograde technique. Finally, the dilated stricture is calibrated by pulling an inflated balloon through the previously strictured area without difficulty. An attempt was made to achieve an esophageal diameter of 15 mm at the initial dilatation episode, and patient discomfort was used as a guide as to the final diameter. The balloon dilatation technique was highly successful, and a stricture diameter of 15 mm (45-47 French) was achieved at the initial dilatation in most instances. Malignant strictures were easily dilated. Balloon dilatation is convenient, effective, quick, and potentially safer than the previous Eder-Puestow or mercury-filled bougie techniques.

  20. Scientific Balloons for Venus Exploration

    NASA Astrophysics Data System (ADS)

    Cutts, James; Yavrouian, Andre; Nott, Julian; Baines, Kevin; Limaye, Sanjay; Wilson, Colin; Kerzhanovich, Viktor; Voss, Paul; Hall, Jeffery

    Almost 30 years ago, two balloons were successfully deployed into the atmosphere of Venus as an element of the VeGa - Venus Halley mission conducted by the Soviet Union. As interest in further Venus exploration grows among the established planetary exploration agencies - in Europe, Japan, Russia and the United States, use of balloons is emerging as an essential part of that investigative program. Venus balloons have been proposed in NASA’s Discovery program and ESA’s cosmic vision program and are a key element in NASA’s strategic plan for Venus exploration. At JPL, the focus for the last decade has been on the development of a 7m diameter superpressure pressure(twice that of VeGa) capable of carrying a 100 kg payload (14 times that of VeGA balloons), operating for more than 30 days (15 times the 2 day flight duration of the VeGa balloons) and transmitting up to 20 Mbit of data (300 times that of VeGa balloons). This new generation of balloons must tolerate day night transitions on Venus as well as extended exposure to the sulfuric acid environment. These constant altitude balloons operating at an altitude of about 55 km on Venus where temperatures are benign can also deploy sondes to sound the atmosphere beneath the probe and deliver deep sondes equipped to survive and operate down to the surface. The technology for these balloons is now maturing rapidly and we are now looking forward to the prospects for altitude control balloons that can cycle repeatedly through the Venus cloud region. One concept, which has been used for tropospheric profiling in Antarctica, is the pumped-helium balloon, with heritage to the anchor balloon, and would be best adapted for flight above the 55 km level. Phase change balloons, which use the atmosphere as a heat engine, can be used to investigate the lower cloud region down to 30 km. Progress in components for high temperature operation may also enable investigation of the deep atmosphere of Venus with metal-based balloons.

  1. Hemodialysis Tunneled Catheter Noninfectious Complications

    PubMed Central

    Miller, Lisa M.; MacRae, Jennifer M.; Kiaii, Mercedeh; Clark, Edward; Dipchand, Christine; Kappel, Joanne; Lok, Charmaine; Luscombe, Rick; Moist, Louise; Oliver, Matthew; Pike, Pamela; Hiremath, Swapnil

    2016-01-01

    Noninfectious hemodialysis catheter complications include catheter dysfunction, catheter-related thrombus, and central vein stenosis. The definitions, causes, and treatment strategies for catheter dysfunction are reviewed below. Catheter-related thrombus is a less common but serious complication of catheters, requiring catheter removal and systemic anticoagulation. In addition, the risk factors, clinical manifestation, and treatment options for central vein stenosis are outlined. PMID:28270922

  2. Concurrent Angioplasty Balloon Placement for Stent Delivery through Jugular Venous Bulb for Treating Cerebral Venous Sinus Stenosis. Technical Report.

    PubMed

    Qureshi, Adnan I; Khan, Asif A; Capistrant, Rachel; Qureshi, Mushtaq H; Xie, Kevin; Suri, M Fareed K

    2016-10-01

    To report upon technique of concurrent placement of angioplasty balloon at the internal jugular vein and sigmoid venous sinus junction to facilitate stent delivery in two patients in whom stent delivery past the jugular bulb was not possible. A 21-year-old woman and a 41-year-old woman with worsening headaches, visual obscuration or diplopia were treated for pseudotumor cerebri associated with transverse venous stenosis. Both patients had undergone primary angioplasty, which resulted in improvement in clinical symptoms followed by the recurrence of symptoms with restenosis at the site of angioplasty. After multiple attempts at stent delivery through jugular venous bulb were unsuccessful, a second guide catheter was placed in the ipsilateral internal jugular vein through contralateral femoral venous approach. A 6 mm × 20 mm (left) or 5 × 15 mm (right) angioplasty balloon was placed across the internal jugular vein and sigmoid sinus junction and partially inflated until the inflation and relative straightening of the junction was observed. In both patients, the internal jugular vein and sigmoid sinus junction was successfully traversed by the stent delivery system in a parallel alignment to inflated balloon. Balloon mounted stent was deployed at the site of restenosis with near complete resolution of lumen narrowing delivery and improvement in clinical symptoms. We report a technique for realignment and diameter change with concurrent placement and partial inflation of angioplasty balloon at the jugular venous bulb to facilitate stent delivery into the sigmoid and transverse venous sinuses in circumstances where multiple attempts at stent delivery are unsuccessful.

  3. Spontaneous intrapartum vesicouterine fistula.

    PubMed

    Kaaki, Bilal; Gyves, Michael; Goldman, Howard

    2006-02-01

    Vesicouterine fistulae as an obstetrical complication have been reported only in women with a history of cesarean. We present a patient with no such history who developed a vesicouterine fistula after vaginal delivery. A 43-year-old gravida 5 at term with no history of cesarean presented in the latent phase of labor. Gross hematuria was noted intrapartum, and a foley catheter was placed. A cystogram showed an extraperitoneal bladder perforation. The patient had urinary incontinence despite Foley catheter drainage. The diagnosis of vesicouterine fistula was made by cystoscopy and fistulogram. The patient had a successful repair at 3 months. This is a rare case of a vesicouterine fistula developing during a pregnancy with no previous cesarean. Accurate diagnosis is essential because surgical repair has an excellent outcome.

  4. Scientific Ballooning Activities and Recent Developments in Technology and Instrumentation of the TIFR Balloon Facility, Hyderabad

    NASA Astrophysics Data System (ADS)

    Buduru, Suneel Kumar

    2016-07-01

    The Balloon Facility of Tata Institute of Fundamental Research (TIFR-BF) is a unique center of expertise working throughout the year to design, fabricate and launch scientific balloons mainly for space astronomy, atmospheric science and engineering experiments. Recently TIFR-BF extended its support to new user scientists for conducting balloon launches for biological and middle atmospheric sciences. For the first time two balloon launches conducted for sending live lab rats to upper stratosphere and provided launch support for different balloon campaigns such as Tropical Tropopause Dynamics (TTD) to study water vapour content in upper tropospheric and lower stratospheric regions over Hyderabad and the other balloon campaign to study the Asian Tropopause Aerosol Layer (BATAL) during the Indian summer monsoon season. BATAL is the first campaign to conduct balloon launches during active (South-West) monsoon season using zero pressure balloons of different volumes. TIFR-BF also provided zero pressure and sounding balloon support to various research institutes and organizations in India and for several international space projects. In this paper, we present details on our increased capability of balloon fabrication for carrying heavier payloads, development of high strength balloon load tapes and recent developments of flight control and safety systems. A summary of the various flights conducted in two years will be presented along with the future ballooning plans.

  5. Telescope Systems for Balloon-Borne Research

    NASA Technical Reports Server (NTRS)

    Swift, C. (Editor); Witteborn, F. C. (Editor); Shipley, A. (Editor)

    1974-01-01

    The proceedings of a conference on the use of balloons for scientific research are presented. The subjects discussed include the following: (1) astronomical observations with balloon-borne telescopes, (2) orientable, stabilized balloon-borne gondola for around-the-world flights, (3) ultraviolet stellar spectrophotometry from a balloon platform, (4) infrared telescope for balloon-borne infrared astronomy, and (5) stabilization, pointing, and command control of balloon-borne telescopes.

  6. Status of the NASA Balloon Program

    NASA Astrophysics Data System (ADS)

    Needleman, H. C.; Nock, R. S.; Bawcom, D. W.

    1993-02-01

    In the early 1980's the U.S. National Aeronautics and Space Administration (NASA) Balloon Program was faced with a problem of catastrophic balloon failures. In 1986 a balloon recovery program was initiated. This program included qualification of new balloon films, and investigations into materials, processing, structures and performance of balloons. This recovery program has been very successful. To date, more than 100 balloons manufactured of newly developed films have been flown with unprecedented success. There has been much progress made across the spectrum of balloon related disciplines. A new design philosophy has been developed and is being used for all NASA balloons. An updated balloon reliability and quality assurance program is in effect. The long duration balloon development project has been initiated with the first flight test having been conducted in December 1989 from Antarctica. A comprehensive research and development (R&D) effort has been initiated and is progressing well. The progress, status and future plans for these and other aspects of the NASA program, along with a description of the comprehensive balloon R&D activity, will be presented.

  7. 77 FR 7589 - Neurological Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-13

    ... current knowledge about the safety and effectiveness of the Wingspan Stent System with Gateway PTA Balloon... premarket and postmarket data. The Wingspan Stent System with Gateway PTA Balloon Catheter is a neurovascular stent, balloon catheter, and delivery system consisting of the following components: 1. Wingspan...

  8. Peritoneal Dialysis Catheter Insertion.

    PubMed

    Crabtree, John H; Chow, Kai-Ming

    2017-01-01

    The success of peritoneal dialysis as renal-replacement therapy depends on a well-functioning peritoneal catheter. Knowledge of best practices in catheter insertion can minimize the risk of catheter complications that lead to peritoneal dialysis failure. The catheter placement procedure begins with preoperative assessment of the patient to determine the most appropriate catheter type, insertion site, and exit site location. Preoperative preparation of the patient is an instrumental step in facilitating the performance of the procedure, avoiding untoward events, and promoting the desired outcome. Catheter insertion methods include percutaneous needle-guidewire with or without image guidance, open surgical dissection, peritoneoscopic procedure, and surgical laparoscopy. The insertion technique used often depends on the geographic availability of material resources and local provider expertise in placing catheters. Independent of the catheter implantation approach, adherence to a number of universal details is required to ensure the best opportunity for creating a successful long-term peritoneal access. Finally, appropriate postoperative care and catheter break-in enables a smooth transition to dialysis therapy. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. The National Scientific Balloon Facility. [balloon launching capabilities of ground facility

    NASA Technical Reports Server (NTRS)

    Kubara, R. S.

    1974-01-01

    The establishment and operation of the National Scientific Balloon Facility are discussed. The balloon launching capabilities are described. The ground support systems, communication facilities, and meteorological services are analyzed.

  10. Investigation of hot air balloon fatalities.

    PubMed

    McConnell, T S; Smialek, J E; Capron, R G

    1985-04-01

    The rising popularity of the sport of hot air ballooning has been accompanied by several recent incidents, both in this country and other parts of the world, where mechanical defects and the improper operation of balloons have resulted in several fatalities. A study was conducted to identify the location and frequency of hot air ballooning accidents. Furthermore, the study attempted to identify those accidents that were the result of improper handling on the part of the balloon operators and those that were related to specific defects in the construction of the balloon. This paper presents a background of the sport of hot air ballooning, together with an analysis of the construction of a typical hot air balloon, pointing out the specific areas where defects may occur that could result in a potential fatal balloon crash. Specific attention is given to the two recent balloon crashes that occurred in Albuquerque, N.M., hot air balloon capital of the world, and that resulted in multiple fatalities.

  11. Septotomy and Balloon Dilation to Treat Chronic Leak After Sleeve Gastrectomy: Technical Principles.

    PubMed

    Campos, Josemberg Marins; Ferreira, Flávio Coelho; Teixeira, André F; Lima, Jones Silva; Moon, Rena C; D'Assunção, Marco Aurélio; Neto, Manoel Galvão

    2016-08-01

    Chronic leaks after laparoscopic sleeve gastrectomy (LSG) are often difficult to treat by endoscopy metallic stent. Septotomy has been indicated as an effective procedure, but the technical aspects have not been detailed in previous publications (Campos JM, Siqueira LT, Ferraz AA, et al., J Am Coll Surg 204(4):711, 2007; Baretta G, Campos J, Correia S, et al., Surg Endosc 29(7):1714-20, 2015; Campos JM, Pereira EF, Evangelista LF, et al., Obes Surg 21(10):1520-9, 2011). We herein present a video (6 min) demonstrating the maneuver principles of this technique, showing it as a safe and feasible approach. A 32-year-old male, with BMI 43.4 kg/m(2), underwent LSG. On the tenth POD, he presented with a leak and initially was managed with the following approach: laparoscopic exploration, drainage, endoclips, and 20-mm balloon dilation. However, the leak remained for a period of 6 months. On the endoscopy, a septum was identified between the leak site and gastric pouch, so it was decided to "reshape" this area by septotomy. Septotomy procedure: Sequential incisions were performed using argon plasma coagulation (APC) with 2.5 flow and 50 W (WEM, SP, Brazil) over the septum in order to allow communication between the perigastric cavity (leak site) and the gastric lumen. The principles below must be followed: (1) Scope position: the endoscopist's left hand holds the control body of the gastroscope while the right hand holds the insertion tube; the APC catheter has no need to be fixed. This avoids movements and unprogrammed maneuvers. (2) Before cutting, the septum is placed in the six o'clock position on the endoscopic view, by rotating the gastroscope. (3) The septum is sectioned until the bottom of the perigastric cavity (leak site). (4) That section is made towards the staple line. (5) Just after the septotomy, a Savory-Gilliard guidewire (Cook Medical, Indiana, USA) through the scope must be inserted until the duodenum, followed by 30-mm balloon (Rigiflex®, Boston

  12. A comparative study of internally and externally capped balloons using small scale test balloons

    NASA Technical Reports Server (NTRS)

    Bell, Douglas P.

    1994-01-01

    Caps have been used to structurally reinforce scientific research balloons since the late 1950's. The scientific research balloons used by the National Aeronautics and Space Administration (NASA) use internal caps. A NASA cap placement specification does not exist since no empirical information exisits concerning cap placement. To develop a cap placement specification, NASA has completed two in-hangar inflation tests comparing the structural contributions of internal caps and external caps. The tests used small scale test balloons designed to develop the highest possible stresses within the constraints of the hangar and balloon materials. An externally capped test balloon and an internally capped test balloon were designed, built, inflated and simulated to determine the structural contributions and benefits of each. The results of the tests and simulations are presented.

  13. Balloons Revisited

    ERIC Educational Resources Information Center

    Jeskova, Z.; Featonby, D.; Fekova, V.

    2012-01-01

    Whilst everyone is familiar with the process of blowing up a balloon, few of us have gone further to quantify the actual pressures involved at different stages in the inflation process. This paper seeks to describe experiments to fill some of those gaps and examine some of the apparently anomalous behaviour of connected balloons. (Contains 12…

  14. Unmanned powered balloons

    NASA Technical Reports Server (NTRS)

    Korn, A. O.

    1975-01-01

    In the late 1960's several governmental agencies sponsored efforts to develop unmanned, powered balloon systems for scientific experimentation and military operations. Some of the programs resulted in hardware and limited flight tests; others, to date, have not progressed beyond the paper study stage. Balloon system designs, materials, propulsion units and capabilities are briefly described, and critical problem areas are pointed out which require further study in order to achieve operational powered balloon systems capable of long duration flight at high altitudes.

  15. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ni, Nina, E-mail: nina.ni@yale.edu; Mojibian, Hamid; Pollak, Jeffrey

    To compare the rates of central venous stenosis in patients undergoing hemodialysis who underwent disruption of fibrin sheath with percutaneous transluminal angioplasty balloons and those who underwent over-the-wire catheter exchange. This study is a retrospective review of 209 percutaneous transluminal angioplasty balloon disruption and 1304 over-the-wire catheter exchange procedures performed in 753 patients. Approval from the Human Investigations Committee was obtained for this study. Up to 10-year follow-up was performed. A {chi}{sup 2} test was used to compare the rates of central venous stenosis after balloon disruption versus catheter exchange. A t-test was used to compare time to central venousmore » stenosis development. Of the 753 patients in the study, 127 patients underwent balloon disruption of fibrin sheath and 626 had catheter exchange. Within the balloon disruption group, 18 (14.2%) of 127 patients subsequently developed central venous stenosis, compared with 44 (7.0%) of 626 in the catheter exchange group (P < 0.01, {chi}{sup 2} test). Time to central venous stenosis development was approximately 3 years in both groups and not significantly different (1371 and 1010 days, P = 0.20). A total of 25.2% of patients in the balloon disruption group had four or more subsequent catheter exchanges, versus 12.6% in the catheter exchange group (P < 0.01, {chi}{sup 2} test). In conclusions, there is a possible association between percutaneous transluminal angioplasty balloon disruption of fibrin sheath and late-onset central venous stenosis. Because venography was not routinely performed in catheter exchange patients, future randomized studies are necessary to confirm these findings.« less

  16. Compensation for Unconstrained Catheter Shaft Motion in Cardiac Catheters

    PubMed Central

    Degirmenci, Alperen; Loschak, Paul M.; Tschabrunn, Cory M.; Anter, Elad; Howe, Robert D.

    2016-01-01

    Cardiac catheterization with ultrasound (US) imaging catheters provides real time US imaging from within the heart, but manually navigating a four degree of freedom (DOF) imaging catheter is difficult and requires extensive training. Existing work has demonstrated robotic catheter steering in constrained bench top environments. Closed-loop control in an unconstrained setting, such as patient vasculature, remains a significant challenge due to friction, backlash, and physiological disturbances. In this paper we present a new method for closed-loop control of the catheter tip that can accurately and robustly steer 4-DOF cardiac catheters and other flexible manipulators despite these effects. The performance of the system is demonstrated in a vasculature phantom and an in vivo porcine animal model. During bench top studies the robotic system converged to the desired US imager pose with sub-millimeter and sub-degree-level accuracy. During animal trials the system achieved 2.0 mm and 0.65° accuracy. Accurate and robust robotic navigation of flexible manipulators will enable enhanced visualization and treatment during procedures. PMID:27525170

  17. Catheter-related bloodstream infection.

    PubMed

    Goede, Matthew R; Coopersmith, Craig M

    2009-04-01

    Catheter-related bloodstream infections (CR-BSIs) are a common, frequently preventable complication of central venous catheterization. CR-BSIs can be prevented by strict attention to insertion and maintenance of central venous catheters and removing unneeded catheters as soon as possible. Antiseptic- or antibiotic-impregnated catheters are also an effective tool to prevent infections. The diagnosis of CR-BSI is made largely based on culture results. CR-BSIs should always be treated with antibiotics, and except in rare circumstances the infected catheter needs to be removed.

  18. Scientific Ballooning in India - Recent Developments

    NASA Astrophysics Data System (ADS)

    Manchanda, R. K.; Srinivasan, S.; Subbarao, J. V.

    Established in 1972, the National Balloon Facility operated by TIFR in Hyderabad, India is is a unique facility in the country, which provides a complete solution in scientific ballooning. It is also one of its kind in the world since it combines both, the in-house balloon production and a complete flight support for scientific ballooning. With a large team working through out the year to design, fabricate and launch scientific balloons, the Hyderabad Facility is a unique centre of expertise where the balloon design, Research and Development, the production and launch facilities are located under one roof. Our balloons are manufactured from 100% indigenous components. The mission specific balloon design, high reliability control and support instrumentation, in-house competence in tracking, telemetry, telecommand, data processing, system design and mechanics is a hallmark of the Hyderabad balloon facility. In the past few years we have executed a major programme of upgradation of different components of balloon production, telemetry and telecommand hardware and various support facilities. This paper focuses on our increased capability of balloon production of large sizes up to size of 780,000 M^3 using Antrix film, development of high strength balloon load tapes with the breaking strength of 182 kg, and the recent introduction of S-band telemetry and a commandable timer cut-off unit in the flight hardware. A summary of the various flights conducted in recent years will be presented along with the plans for new facilities.

  19. [Thermal balloon endometrial ablation for dysfunctional uterine bleeding: technical aspects and results. A prospective cohort study of 152 cases].

    PubMed

    Kdous, Moez; Jacob, Denis; Gervaise, Amélie; Risk, Elie; Sauvanet, Eric

    2008-05-01

    Thermal balloon endometrial ablation is a new operative technique recently proposed in the treatment of dysfunctional uterine bleeding. To evaluate the efficacy of thermal balloon endometrial ablation in the treatment of dysfunctional uterine bleeding, and to identify the possible predictive factors for a successful outcome. A prospective study was conducted including 152 patients with chronic abnormal uterine bleeding refractory to medical treatment. All patients were treated by thermal balloon endometrial ablation (Thermachoice, Gynecare) between January 1, 1996 and December 31, 2003. patients were included if their uterine cavities sounded to less than 12 cm and had undergone hysteroscopy, pelvic ultrasound and endometrial biopsie showing no structural or (pre) malignant endometrial abnormalities. A balloon catheter was placed through the cervix and after inflation in the endometrial cavity with 5% dextrose in water, was heated to 87 +/- 5 degrees C. No one required cervical dilatation. Balloon pressures were 160 to 170 mm Hg. All patients underwent 8 minutes of therapy. The average patient was 47 years (range: 30-62 years) and was followed for a mean of 3 years and 7 months (range: 6 months - 8 years). 31.6% of women reported amennorhea, 16.5% hypomenorrhea and 21% eumenorrhea. Menorrhagea persisted in 11.2% of patients. No intraoperative complications and minor postoperative morbidity occured in 10.5% of patients. Three prgnancy complicated by spontaneous abortions were reported after the treatment. A total of 78% of women reported overall satisfaction with the endometrial ablation procedure and 18% were dissatisfied. 17.8% of patients underwent hysterectomy within 1 to 5 years of balloon endometrial ablation. Increasing age and menopause were significantly associated with increased odds of success (p < 0.05). Thermal balloon endometrial ablation is a simple, easy, effective, and minimally invasive procedure in menhorragic women with no desire for further

  20. A central venous catheter coated with benzalkonium chloride for the prevention of catheter-related microbial colonization.

    PubMed

    Moss, H A; Tebbs, S E; Faroqui, M H; Herbst, T; Isaac, J L; Brown, J; Elliott, T S

    2000-11-01

    In an attempt to overcome infections associated with central venous catheters, a new antiseptic central venous catheter coated with benzalkonium chloride on the internal and external surfaces has been developed and evaluated in a clinical trial. Patients (235) randomly received either a triple-lumen central venous catheter coated with benzalkonium chloride (117) or a polyurethane non-antiseptic catheter (118). The incidence of microbial colonization of both catheters and retained antiseptic activity of the benzalkonium chloride device following removal were determined. The benzalkonium chloride resulted in a significant reduction of the incidence of microbial colonization on both the internal and external catheter surfaces. The reduction in colonization was detected at both the intradermal (21 benzalkonium chloride catheters vs. 38 controls, P = 0.0016) and distal segments of the antiseptic-coated catheters. Following catheter removal retained activity was demonstrated in benzalkonium chloride catheters which had been in place for up to 12 days. No patients developed adverse reactions to the benzalkonium chloride catheters. The findings demonstrate that the benzalkonium chloride catheter significantly reduced the incidence of catheter-associated colonization.

  1. Hot-Air Ballooning in Physics Teaching.

    ERIC Educational Resources Information Center

    Haugland, Ole Anton

    1991-01-01

    Describes the modern hot-air balloon and the physics of ballooning. Proposes that students construct their own hot-air balloon and presents an experiment calculating the time needed for a balloon to rise to the ceiling of a gymnasium. (MDH)

  2. Optimum designs for superpressure balloons

    NASA Astrophysics Data System (ADS)

    Smith, M. S.; Rainwater, E. L.

    2004-01-01

    The elastica shape is now well known to be the best basic shape for superpressure balloon design. This shape, also known as the pumpkin, or natural shape for balloons, has been well understood since the early 1900s when it was applied to the determination of the shape of descending parachutes. The elastica shape was also investigated in the 1950s when high strength films were used to produce superpressure cylinder balloons. The need for uniform stress distribution in shells of early superpressure balloons led to a long period of the development of spherical superpressure balloons. Not until the late 1970s was the elastica shape revisited for the purpose of the producing superpressure balloons. This paper will review various development efforts in the field of superpressure design and will elaborate on the current state-of-the-art with suggestions for future developments.

  3. Flow Past a Descending Balloon

    NASA Technical Reports Server (NTRS)

    Baginski, Frank

    2001-01-01

    In this report, we present our findings related to aerodynamic loading of partially inflated balloon shapes. This report will consider aerodynamic loading of partially inflated inextensible natural shape balloons and some relevant problems in potential flow. For the axisymmetric modeling, we modified our Balloon Design Shape Program (BDSP) to handle axisymmetric inextensible ascent shapes with aerodynamic loading. For a few simple examples of two dimensional potential flows, we used the Matlab PDE Toolbox. In addition, we propose a model for aerodynamic loading of strained energy minimizing balloon shapes with lobes. Numerical solutions are presented for partially inflated strained balloon shapes with lobes and no aerodynamic loading.

  4. Status of the NASA Balloon Program

    NASA Technical Reports Server (NTRS)

    Needleman, H. C.; Nock, R. S.; Bawcom, D. W.

    1993-01-01

    The NASA Balloon Program (BP) is examined in an overview of design philosophy, R&D activities, flight testing, and the development of a long-duration balloon for Antarctic use. The Balloon Recovery Program was developed to qualify the use of existing films and to design improved materials and seals. Balloon flights are described for studying the supernova SN1987a, and systems were developed to enhance balloon campaigns including mobile launch vehicles and tracking/data-acquisition systems. The technical approach to long-duration ballooning is reviewed which allows the use of payloads of up to 1350 kg for two to three weeks. The BP is responsible for the development of several candidate polyethylene balloon films as well as design/performance standards for candidate balloons. Specific progress is noted in reliability and in R&D with respect to optimization of structural design, resin blending, and extrusion.

  5. Temporary balloon occlusion of the common hepatic artery for administration of yttrium-90 resin microspheres in a patient with patent hepatoenteric collaterals.

    PubMed

    Mahvash, Armeen; Zaer, Navid; Shaw, Colette; Chasen, Beth; Avritscher, Rony; Murthy, Ravi

    2012-02-01

    The most common serious complication of yttrium-90 ((90)Y) therapy is gastrointestinal ulceration caused by extrahepatic microsphere dispersion. The authors describe the use of a balloon catheter for temporary occlusion of the common hepatic artery to reverse hepatoenteric flow for lobar administration of resin microspheres when coil embolization of a retroportal artery was impossible. At 9 months after treatment, the patient had no gastrointestinal side effects and showed a partial response. Copyright © 2012 SIR. Published by Elsevier Inc. All rights reserved.

  6. Catheter associated urinary tract infections

    PubMed Central

    2014-01-01

    Urinary tract infection attributed to the use of an indwelling urinary catheter is one of the most common infections acquired by patients in health care facilities. As biofilm ultimately develops on all of these devices, the major determinant for development of bacteriuria is duration of catheterization. While the proportion of bacteriuric subjects who develop symptomatic infection is low, the high frequency of use of indwelling urinary catheters means there is a substantial burden attributable to these infections. Catheter-acquired urinary infection is the source for about 20% of episodes of health-care acquired bacteremia in acute care facilities, and over 50% in long term care facilities. The most important interventions to prevent bacteriuria and infection are to limit indwelling catheter use and, when catheter use is necessary, to discontinue the catheter as soon as clinically feasible. Infection control programs in health care facilities must implement and monitor strategies to limit catheter-acquired urinary infection, including surveillance of catheter use, appropriateness of catheter indications, and complications. Ultimately, prevention of these infections will require technical advances in catheter materials which prevent biofilm formation. PMID:25075308

  7. Severe complication of posterior nasal packing: Case Report.

    PubMed

    Pinto, José Antônio; Cintra, Pedro Paulo Vivacqua da Cunha; Sônego, Thiago Branco; Leal, Carolina de Farias Aires; Artico, Marina Spadari; Soares, Josemar Dos Santos

    2012-10-01

     Severe Epistaxis is common in patients with head trauma, especially when associated with multiple fractures of the face and skull base. Several methods of controlling bleeding that can be imposed. The anterior nasal tapenade associated with posterior Foley catheter is one of the most widespread, and the universal availability of necessary materials or their apparent ease of execution.  Case report on control of severe epistaxis after severe TBI, with posterior nasal packing by Foley catheter and control tomography showing multiple fractures of the skull base and penetration of the probe into the brain parenchyma.  This is a rare but possible complication in the treatment of severe nose bleeds associated with fracture of the skull base. This brief report highlights risks related to the method and suggests some care to prevent complications related through a brief literature review.

  8. 12-Month Results From the First-in-Human Randomized Study of the Ranger Paclitaxel-Coated Balloon for Femoropopliteal Treatment.

    PubMed

    Steiner, Sabine; Willfort-Ehringer, Andrea; Sievert, Horst; Geist, Volker; Lichtenberg, Michael; Del Giudice, Costantino; Sauguet, Antoine; Diaz-Cartelle, Juan; Marx, Claudia; Ströbel, Armin; Schult, Ingolf; Scheinert, Dierk

    2018-05-28

    The authors sought to evaluate the performance of the Ranger paclitaxel-coated balloon versus uncoated balloon angioplasty for femoropopliteal lesions at 12 months. Drug-coated balloons (DCBs) are a promising endovascular treatment option for peripheral artery disease of the femoropopliteal segment, and each unique device requires dedicated clinical study. The prospective, randomized RANGER SFA (Comparison of the Ranger™ Paclitaxel-Coated PTA Balloon Catheter and Uncoated PTA Balloons in Femoropopliteal Arteries) study (NCT02013193) enrolled 105 patients with symptomatic lower limb ischemia (Rutherford category 2 to 4) and stenotic lesions in the nonstented femoropopliteal segment at 10 European centers. Seventy-one patients (mean age 68 ± 8 years, n = 53 men) were enrolled in the Ranger DCB arm, and 34 patients (mean age 67 ± 9 years, n = 23 men) were assigned to the control group. Twelve-month analysis included patency, safety, and clinical outcomes and quality-of-life assessments. The DCB group had a greater primary patency rate at 12 months (Kaplan-Meier estimate 86.4% vs. 56.5%), with a significantly longer time to patency failure (log-rank p < 0.001). The estimated freedom from target lesion revascularization rate was 91.2% in the DCB group and 69.9% in the control group at 12 months, with a significantly longer time to reintervention (p = 0.010). No target limb amputations or device-related deaths occurred in either group. Twelve-month results show that patency was maintained longer after Ranger DCB treatment than after conventional balloon angioplasty, and this result was associated with a low revascularization rate and good clinical outcomes. Copyright © 2018 The Authors. Published by Elsevier Inc. All rights reserved.

  9. Preoperative optimization of multi-organ failure following acute myocardial infarction and ischemic mitral regurgitation by placement of a transthoracic intra-aortic balloon pump.

    PubMed

    Umakanthan, Ramanan; Dubose, Robert; Byrne, John G; Ahmad, Rashid M

    2010-10-01

    The management of acute myocardial infarction with resultant acute ischemic mitral regurgitation and acute multi-organ failure can prove to be a very challenging scenario. The presence of concomitant vascular disease can only serve to further compromise the complexity of the situation. We demonstrate a new indication for the transthoracic intra-aortic balloon pump as a preoperative means of unloading the heart and improving clinical outcome in such high-risk patients with severe vascular disease. We present the case of a 75-year-old man with a history of severe vascular disease who was transferred emergently to Vanderbilt University Medical Center with an acute inferolateral wall myocardial infarction resulting in severe acute ischemic mitral regurgitation and acute multi-organ failure. He presented with shock liver (serum glutamic-oxaloacetic transaminase [SGOT] of 958), renal failure (creatinine of 3.0), and respiratory failure with a pH of 7.18. Emergent cardiac catheterization revealed 100% occlusion of the left circumflex artery as well as severe ileofemoral disease. The advanced nature of his ileofemoral disease was such that the arterial access catheter occluded the right femoral artery. The duration of time that the catheter was in the artery led to transient limb ischemia with an elevation of his creatine phosphokinase (CPK) to 10,809. Balloon angioplasty followed by stent placement was successfully performed, which restored flow to the coronary vessel. Given the grave nature of the patient's condition, we were very concerned that immediate operative intervention for his condition would entail prohibitively high risk. In fact, the Society of Thoracic Surgeons predicted risk adjusted mortality was calculated to be 56%. In order to minimize patient mortality and morbidity, it was critical to help restore perfusion and organ recovery. Therefore, we decided that the chances for this patient's survival would improve if his condition could be optimized by

  10. Newly Designed Y-configured Single-Catheter Stenting for the Treatment of Hilar-Type Nonanastomotic Biliary Strictures After Orthotopic Liver Transplantation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang Changming; Li Xuan, E-mail: lixuanbysy@163.com; Song Shibing

    2012-02-15

    Purpose: This study was designed to introduce our novel technique of percutaneous single catheter placement into the hilar bile ducts strictures while fulfilling the purpose of bilateral biliary drainage and stenting. We investigated the efficacy and safety of the technique for the treatment of hilar nonanastomotic biliary strictures. Methods: Ten patients who were post-orthotopic liver transplantation between July 2000 and July 2010 were enrolled in this study. Percutaneous Y-configured single-catheter stenting for bilateral bile ducts combined with balloon dilation was designed as the main treatment approach. Technical success rate, clinical indicators, complications, and recurrent rate were analyzed. Results: Technical successmore » rate was 100%. Nine of the ten patients had biochemical normalization, cholangiographic improvement, and clinical symptoms relief. None of them experienced recurrence in a median follow-up of 26 months after completion of therapy and removal of all catheters. Complications were minor and limited to two patients. The one treatment failure underwent a second liver transplantation but died of multiple system organ failure. Conclusions: Percutaneous transhepatic Y-configured single-catheter stenting into the hilar bile ducts is technically feasible. The preliminary trial of this technique combined with traditional PTCD or choledochoscopy for the treatment of hilar biliary strictures after orthotopic liver transplantation appeared to be effective and safe. Yet, further investigation is needed.« less

  11. Scientific ballooning in India Recent developments

    NASA Astrophysics Data System (ADS)

    Manchanda, R. K.

    Established in 1971, the National Balloon Facility operated by TIFR in Hyderabad, India, is a unique facility in the country, which provides a complete solution in scientific ballooning. It is also one of its kind in the world since it combines both, the in-house balloon production and a complete flight support for scientific ballooning. With a large team working through out the year to design, fabricate and launch scientific balloons, the Hyderabad Facility is a unique centre of expertise where the balloon design, research and development, the production and launch facilities are located under one roof. Our balloons are manufactured from 100% indigenous components. The mission specific balloon design, high reliability control and support instrumentation, in-house competence in tracking, telemetry, telecommand, data processing, system design and mechanics is its hallmark. In the past few years, we have executed a major programme of upgradation of different components of balloon production, telemetry and telecommand hardware and various support facilities. This paper focuses on our increased capability of balloon production of large sizes up to 780,000 m 3 using Antrix film, development of high strength balloon load tapes with the breaking strength of 182 kg, and the recent introduction of S-band telemetry and a commandable timer cut-off unit in the flight hardware. A summary of the various flights conducted in recent years will be presented along with the plans for new facilities.

  12. A new approach to fertility-preserving surgery in patients with placenta accreta.

    PubMed

    Barinov, Sergey; Tirskaya, Yuliya; Medyannikova, Irina; Shamina, Inna; Shavkun, Inna

    2017-12-05

    The aim of this study was to evaluate the efficacy of a novel combined surgical approach utilising: (1) two autonomous balloon Zhukovsky catheters (vaginal and uterine), (2) bilateral ligation of the descending uterine artery branches, (3) external supraplacental pleated sutures, and (4) either excision of a small area of placenta accreta or full metroplasty, for the management of uterine bleeding associated with placenta accreta of various severity. The study included medical records of 92 pregnant women with placenta accreta undergoing a caesarean section. To evaluate the efficacy of the proposed management strategy, study participants were divided into three groups. In Group 1 (controls, n = 47), we utilised the combination of bilateral ligation, Barinov external supraplacental pleated sutures, and either excision of the tightly attached portion of placenta accreta or metroplasty. In Group 2 (n = 20), the abovementioned surgical techniques were additionally combined with balloon tamponade using an intrauterine Zhukovsky catheter. In Group 3 (n = 25), we additionally used an intravaginal Zhukovsky balloon catheter to enhance the efficacy of intrauterine tamponade. The use of an intrauterine balloon catheter combined with metroplasty was associated with a reduction in blood loss volume and blood transfusion rate by 1.9-fold, while the use of intravaginal balloon catheter reduced blood transfusion rate by 2.4-fold. The uterine balloon catheter reduced the risk of hysterectomy by 11-fold. Simultaneous use of two Zhukovsky balloon catheters (intravaginal and intrauterine) during caesarean section facilitates fertility-preserving surgery in patients with placenta accreta even in the cases of low-segment bleeding, thereby representing a promising approach to management of these patients.

  13. Ballooning for Biologists: Mission Essentials for Flying Experiments on Large NASA Balloons

    NASA Technical Reports Server (NTRS)

    Smith, David J.; Sowa, Marianne

    2017-01-01

    Despite centuries of scientific balloon flights, only a handful of experiments have produced biologically-relevant results. Yet unlike orbital spaceflight, it is much faster and cheaper to conduct biology research with balloons, sending specimens to the near space environment of Earths stratosphere. Samples can be loaded the morning of a launch and sometimes returned to the laboratory within one day after flying. The National Aeronautics and Space Administration (NASA) flies large, unmanned scientific balloons from all over the globe, with missions ranging from hours to weeks in duration. A payload in the middle portion of the stratosphere (approx. 35 km above sea level) will be exposed to an environment similar to the surface of Mars: temperatures generally around -36 C, atmospheric pressure at a thin 1 kPa, relative humidity levels <1%, and a harsh illumination of ultraviolet (UV) and cosmic radiation levels (about 100 W/sq m and 0.1 mGy/d, respectively) that can be obtained nowhere else on the surface of the Earth, including environmental chambers and particle accelerator facilities attempting to simulate space radiation effects. Considering the operational advantages of ballooning and the fidelity of space-like stressors in the stratosphere, researchers in aerobiology, astrobiology, and space biology can benefit from balloon flight experiments as an intermediary step on the extraterrestrial continuum (ground, low Earth orbit, and deep space studies). Our presentation targets biologists with no background or experience in scientific ballooning. We will provide an overview of large balloon operations, biology topics that can be uniquely addressed in the stratosphere, and a roadmap for developing payloads to fly with NASA.

  14. Successful percutaneous coronary intervention with GuideLiner® catheter for subtotal occlusive lesion in the right coronary artery with anomalous origin from the left sinus of Valsalva: a case report.

    PubMed

    Shirota, Ayumi; Nomura, Tetsuya; Kubota, Hiroshi; Taminishi, Shunta; Urata, Ryota; Sugimoto, Takeshi; Higuchi, Yusuke; Kato, Taku; Keira, Natsuya; Tatsumi, Tetsuya

    2015-07-28

    Because of the unusual anatomy of an anomalous origin of the right coronary artery from the left sinus of Valsalva, selective cannulation of the guiding catheter in percutaneous coronary intervention for these cases is always challenging. A 58-year-old Japanese man was admitted to our hospital complaining of worsening exertional chest pain. He was suspected of having unstable angina pectoris and underwent cardiac catheterization. We found a subtotal occlusive lesion in the mid-portion of his right coronary artery that originated from the left sinus of Valsalva. On the previous percutaneous coronary intervention, we failed to cannulate the guiding catheter to the anomalous orifice of the right coronary artery. Therefore, we decided to use the GuideLiner catheter for stable back-up support from the beginning. A 6Fr GuideLiner catheter was introduced into the right coronary artery by anchoring it coaxially with a semi-compliant balloon catheter. And we successfully deployed two drug-eluting stents by crossing over the posterior-descending artery. Final angiography demonstrated favorable dilatation of the target lesion, and native blood flow in the right coronary artery was completely recovered. GuideLiner is a monorail-type "child" support catheter that facilitates coaxial guiding catheter engagement and an appropriate back-up force, achieving successful device delivery to target lesions in this kind of complex percutaneous coronary intervention.

  15. Histological and Morphometric Analyses for Rat Carotid Artery Balloon Injury Studies

    PubMed Central

    Tulis, David Anthony

    2010-01-01

    i. Summary Experiments aimed at analyzing the response of blood vessels to mechanical injury and ensuing remodeling responses often employ the highly characterized carotid artery balloon injury model in laboratory rats. This approach utilizes luminal insertion of a balloon embolectomy catheter into the common carotid artery with inflation and withdrawal resulting in an injury characterized by vascular endothelial cell (EC) denudation and medial wall distension. The adaptive response to this injury is typified by robust vascular smooth muscle cell (SMC) replication and migration, SMC apoptosis and necrosis, enhanced synthesis and deposition of extracellular matrix (ECM) components, partial vascular EC regeneration from the border zones, luminal narrowing and establishment of a neointima in time-dependent fashion. Evaluation of these adaptive responses to blood vessel injury can include acute and longer-term qualitative and quantitative measures including expression analyses, activity assays, immunostaining for a plethora of factors and signals, and morphometry of neointima formation and gross mural remodeling. This chapter presents a logical continuation of Chapter    in this series that offers details for performing the rat carotid artery balloon injury model in a standard laboratory setting by providing commonly used protocols for performing histological and morphometric analyses in such studies. Moreover, procedures, caveats, and considerations included in this chapter are highly relevant for alternative animal vascular physiology/pathophysiology studies and in particular those related to mechanisms of vascular injury and repair. Included in this chapter are specifics for in situ perfusion-fixation, tissue harvesting and processing for both snap-frozen and paraffin-embedded protocols, specimen embedding and sectioning, slide preparation, several standard histological staining steps, and routine morphological assessment. Included in Notes are important caveats

  16. Realistic Anatomical Prostate Models for Surgical Skills Workshops Using Ballistic Gelatin for Nerve-Sparing Radical Prostatectomy and Fruit for Simple Prostatectomy

    PubMed Central

    Lindner, Uri; Klotz, Laurence

    2011-01-01

    Purpose Understanding of prostate anatomy has evolved as techniques have been refined and improved for radical prostatectomy (RP), particularly regarding the importance of the neurovascular bundles for erectile function. The objectives of this study were to develop inexpensive and simple but anatomically accurate prostate models not involving human or animal elements to teach the terminology and practical aspects of nerve-sparing RP and simple prostatectomy (SP). Materials and Methods The RP model used a Foley catheter with ballistics gelatin in the balloon and mesh fabric (neurovascular bundles) and balloons (prostatic fascial layers) on either side for the practice of inter- and intrafascial techniques. The SP model required only a ripe clementine, for which the skin represented compressed normal prostate, the pulp represented benign tissue, and the pith mimicked fibrous adhesions. A modification with a balloon through the fruit center acted as a "urethra." Results Both models were easily created and successfully represented the principles of anatomical nerve-sparing RP and SP. Both models were tested in workshops by urologists and residents of differing levels with positive feedback. Conclusions Low-fidelity models for prostate anatomy demonstration and surgical practice are feasible. They are inexpensive and simple to construct. Importantly, these models can be used for education on the practical aspects of nerve-sparing RP and SP. The models will require further validation as educational and competency tools, but as we move to an era in which human donors and animal experiments become less ethical and more difficult to complete, so too will low-fidelity models become more attractive. PMID:21379431

  17. Nursing students' self-evaluation using a video recording of foley catheterization: effects on students' competence, communication skills, and learning motivation.

    PubMed

    Yoo, Moon Sook; Yoo, Il Young; Lee, Hyejung

    2010-07-01

    An opportunity for a student to evaluate his or her own performance enhances self-awareness and promotes self-directed learning. Using three outcome measures of competency of procedure, communication skills, and learning motivation, the effects of self-evaluation using a video recording of the student's Foley catheterization was investigated in this study. The students in the experimental group (n = 20) evaluated their Foley catheterization performance by reviewing the video recordings of their own performance, whereas students in the control group (n = 20) received written evaluation guidelines only. The results showed that the students in the experimental group had better scores on competency (p < 0.001), communication skills (p < 0.001), and learning motivation (p = 0.018) than the control group at the post-test, which was conducted 8 weeks after the pretest. Self-awareness of one's own performance developed by reviewing a videotape appears to increase the competency of clinical skills in nursing students. Copyright 2010, SLACK Incorporated.

  18. A stress index model for ascending balloons

    NASA Technical Reports Server (NTRS)

    Smith, I. S.

    1986-01-01

    Attention is given to the development on the part of NASA of a simplified stress 'index' model to establish the relative stress magnitudes along a balloon's gore position as a function of altitude. Application of this model to several hundred balloon flights showed a good correlation between balloon failure rate and stress 'index' level. This model can be used during the balloon design process to lower the levels of stress in the balloon. By increasing the wall thickness of the balloon, adding caps, lengthening caps, or using external caps, lower stress can be accomplished. As a result, in January 1985, the NASA Balloon Program established a stress index specification to limit the design and flight stresses for NASA balloons.

  19. Use of peripherally inserted central catheters as an alternative to central catheters in neurocritical care units.

    PubMed

    DeLemos, Christi; Abi-Nader, Judy; Akins, Paul T

    2011-04-01

    Patients in neurological critical care units often have lengthy stays that require extended vascular access and invasive hemodynamic monitoring. The traditional approach for these patients has relied heavily on central venous and pulmonary artery catheters. The aim of this study was to evaluate peripherally inserted central catheters as an alternative to central venous catheters in neurocritical care settings. Data on 35 patients who had peripherally inserted central catheters rather than central venous or pulmonary artery catheters for intravascular access and monitoring were collected from a prospective registry of neurological critical care admissions. These data were cross-referenced with information from hospital-based data registries for peripherally inserted central catheters and subarachnoid hemorrhage. Complete data were available on 33 patients with Hunt-Hess grade IV-V aneurysmal subarachnoid hemorrhage. Catheters remained in place a total of 649 days (mean, 19 days; range, 4-64 days). One patient (3%) had deep vein thrombosis in an upper extremity. In 2 patients, central venous pressure measured with a peripherally inserted catheter was higher than pressure measured concurrently with a central venous catheter. None of the 33 patients had a central catheter bloodstream infection or persistent insertion-related complications. CONCLUSIONS Use of peripherally inserted central catheters rather than central venous catheters or pulmonary artery catheters in the neurocritical care unit reduced procedural and infection risk without compromising patient management.

  20. Launching Garbage-Bag Balloons.

    ERIC Educational Resources Information Center

    Kim, Hy

    1997-01-01

    Presents a modification of a procedure for making and launching hot air balloons made out of garbage bags. Student instructions for balloon construction, launching instructions, and scale diagrams are included. (DDR)

  1. Rapid guiding catheter swapping for management of rupture during percutaneous venoplasty for idiopathic occlusion of superior vena cava.

    PubMed

    Pandit, Bhagya Narayan; Chaturvedi, Vivek; Parakh, Neeraj; Gade, Sandeep; Trehan, Vijay

    2015-04-01

    Treatment for superior vena cava syndrome (SVCS) by percutaneous interventions has become established as a definitive therapy. However, there is a significant risk of rupture during SVC intervention. We describe an uncommon case that developed SVC rupture during percutaneous intervention for idiopathic SVCS. This was managed successfully with pericardiocentesis and rapid implantation of covered stent in SVC by rapid guiding catheter swapping technique. This, however, led to inadvertent obstruction of left innominate vein which was successfully treated by kissing balloon inflation. At 18-month follow-up, he is asymptomatic with a well apposed patent stent-graft in the SVC.

  2. PRE-INOCULATION OF URINARY CATHETERS WITH ESCHERICHIA COLI 83972 INHIBITS CATHETER COLONIZATION BY ENTEROCOCCUS FAECALIS

    PubMed Central

    TRAUTNER, BARBARA W.; DAROUICHE, RABIH O.; HULL, RICHARD A.; HULL, SHEILA; THORNBY, JOHN I.

    2010-01-01

    Purpose The capacity of a preexisting coating of Escherichia coli 83972 to reduce catheter colonization by Enterococcus faecalis 210 was investigated. Enterococcus was chosen for these trials since it is a common urinary pathogen in patients with an indwelling urinary catheter. Materials and Methods Each experiment tested 3 growth conditions. Group 1 or E. coli plus Enterococcus catheters were exposed to E. coli 83972 for 24 hours and then to Enterococcus for 30 minutes. Group 2 or E. coli alone catheters were incubated in E. coli for 24 hours and then in sterile broth for 30 minutes. Group 3 or Enterococcus alone catheters did not undergo the initial incubation with E. coli before the 30-minute incubation with Enterococcus: All catheters were then incubated in sterile human urine for 24 hours. Catheters were washed with saline and cut into 5, 1 cm. segments. Each segment was sonicated and the sonication fluid was diluted and plated. The results of each of the 5 segments were averaged and the set of experiments was repeated 7 times. Results A preexisting coating of E. coli 83972 reduced catheter colonization by E. faecalis 210 more than 10-fold. Enterococcus alone catheters had a median of 9.7 × 105 enterococci per cm., whereas E. coli plus Enterococcus catheters had a median of 0.38 × 105 enterococci per cm. (p = 0.016). Conclusions Pre-inoculating urinary catheters with E. coli 83972 significantly impedes catheter colonization by Enterococcus: These promising in vitro results prompt the clinical investigation of this particular application of bacterial interference. PMID:11743359

  3. Mechanical properties of ANTRIX balloon film and fabrication of single cap large volume balloons

    NASA Astrophysics Data System (ADS)

    Suneel Kumar, B.; Sreenivasan, S.; Subba Rao, J. V.; Manchanda, R. K.

    2008-11-01

    The zero pressure plastic balloons used for high altitude studies are generally made from polyethylene material. Tensile properties of the thin film polymer are the key parameters for material selection due to extremely low temperature of -90 °C encountered by the balloons in the tropopause region during the ascent at equatorial latitudes. The physical and structural properties of the material determine the uniformity of the stress distribution over the entire shell. Load stresses from the suspended load propagate via load tapes heat sealed along with the gore seals as per the balloon design. A balance between this heat seal strength and the film strength is a desirable property of the basic resin in terms of the bubble strength, gauge uniformity, and long-term storage properties. In addition, the design of the top shell of the balloon and its stress distribution play an important role since only a fraction of the balloon is deployed during the filling operation and the ascent. In this paper we describe the mechanical properties of the 'ANTRIX' film developed by us and the optimized design of single cap balloons, which have been successfully used in our experiments over the past 5 years.

  4. Percutaneous Mitral Valve Dilatation: Single Balloon versus Double Balloon - A Finite Element Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schievano, Silvia; Kunzelman, Karyn; Nicosia, Mark

    2009-01-01

    Background: Percutaneous mitral valve (MV) dilatation is performed with either a single balloon (SB) or double balloon (DB) technique. The aim of this study was to compare the two balloon system results using the finite element (FE) method. Methods and Results: An established FE model of the MV was modified by fusing the MV leaflet edges at commissure level to simulate a stenotic valve (orifice area=180mm2). A FE model of a 30mm SB (low-pressure, elastomeric balloon) and an 18mm DB system (high-pressure, non-elastic balloon) was created. Both SB and DB simulations resulted in splitting of the commissures and subsequent stenosismore » dilatation (final MV area=610mm2 and 560mm2 respectively). Stresses induced by the two balloon systems varied across the valve. At the end of inflation, SB showed higher stresses in the central part of the leaflets and at the commissures compared to DB simulation, which demonstrated a more uniform stress distribution. The higher stresses in the SB analysis were due to the mismatch of the round balloon shape with the oval mitral orifice. The commissural split was not easily accomplished with the SB due to its high compliance. The high pressure applied to the DB guaranteed the commissural split even when high forces were required to break the commissure welds. Conclusions: The FE model demonstrated that MV dilatation can be accomplished by both SB and DB techniques. However, the DB method resulted in higher probability of splitting of the fused commissures and less damage caused to the MV leaflets by overstretching.« less

  5. Technologies developed by CNES balloon team

    NASA Astrophysics Data System (ADS)

    Sosa-Sesma, Sergio; Charbonnier, Jean-Marc; Deramecourt, Arnaud

    CNES balloon team develops and operates all the components of this kind of vehicle: it means envelope and gondola. This abstract will point out only developments done for envelope. Nowadays CNES offers to scientists four types of envelops that cover a large range of mission demands. These envelops are: 1. Zero pressure balloons: Size going from 3,000m3 to 600,000m3, this kind of envelop is ideal for short duration flights (a few hours) but if we use an intelligent management of ballast consumption and if we chose the best launch site, it is possible to perform medium duration flights (10/20 days depending on the ballast on board). Flight train mass starts at 50kg for small balloons and reach 1000kg for larger ones. Zero pressure balloons are inflated with helium gas. 2. Super pressure balloons: Diameter going from 2.5m to 12m, this kind of envelop is ideal for long duration flights (1 to 6 months). Flight train is inside the envelop for small balloons, it means 2.5 diameter meters which is usually called BPCL (Super pressure balloon for Earth boundary layer) and it is about 3kg of mass. Larger ones could lift external flight trains about 50kg of mass. Super pressure balloons are inflated with helium gas. 3. MIR balloons: Size going from 36,000m3 to 46,000m3. Ceiling is reach with helium gas but after three days helium is no longer present inside and lift force is produced by difference of temperature between air inside and air of atmosphere. Flight trains must not be over 50kg. 4. Aero Clipper balloons: A concept to correlate measurements done in oceans and in nearest layers of atmosphere simultaneously. Flight train is made by a "fish" that drags inside water and an atmospheric gondola few meters above "fish", both pushed by a balloon which profits of the wind force. Materials used for construction and assembling depend on balloon type; they are usually made of polyester or polyethylene. Thickness varies from 12 micrometers to 120 micrometers. Balloon assembling

  6. Severe complication of posterior nasal packing: Case Report

    PubMed Central

    Pinto, José Antônio; Cintra, Pedro Paulo Vivacqua da Cunha; Sônego, Thiago Branco; Leal, Carolina de Farias Aires; Artico, Marina Spadari; Soares, Josemar dos Santos

    2012-01-01

    Summary Introduction: Severe Epistaxis is common in patients with head trauma, especially when associated with multiple fractures of the face and skull base. Several methods of controlling bleeding that can be imposed. The anterior nasal tapenade associated with posterior Foley catheter is one of the most widespread, and the universal availability of necessary materials or their apparent ease of execution. Methods: Case report on control of severe epistaxis after severe TBI, with posterior nasal packing by Foley catheter and control tomography showing multiple fractures of the skull base and penetration of the probe into the brain parenchyma. Conclusion: This is a rare but possible complication in the treatment of severe nose bleeds associated with fracture of the skull base. This brief report highlights risks related to the method and suggests some care to prevent complications related through a brief literature review. PMID:25991984

  7. Air Force Cambridge Research Laboratories balloon operations

    NASA Technical Reports Server (NTRS)

    Danaher, T. J.

    1974-01-01

    The establishment and functions of the AFCRL balloon operations facility are discussed. The types of research work conducted by the facility are defined. The facilities which support the balloon programs are described. The free balloon and tethered balloon capabilities are analyzed.

  8. Morphological characterization of selected balloon films and its effects on balloon performances

    NASA Technical Reports Server (NTRS)

    Said, Magdi A.

    1994-01-01

    Morphological characterization of several polyethylene balloon films have been studied using various techniques. The objective is to determine, if any, differentiating structural or morphological features that can be related to the performance of these balloon film materials. The results of the study indicate that the films are composed of either linear low denstiy polyethylene (LLDPE) or low density polyethylene (LDPE). A selective examination of these data imply that films limited degree of branching and larger crystallites size (same % crystallinity) showed good mechanical properties that appear to correlate with their high level of success in balloon flights.

  9. The EUSO-Balloon pathfinder

    NASA Astrophysics Data System (ADS)

    Adams, J. H.; Ahmad, S.; Albert, J.-N.; Allard, D.; Anchordoqui, L.; Andreev, V.; Anzalone, A.; Arai, Y.; Asano, K.; Ave Pernas, M.; Baragatti, P.; Barrillon, P.; Batsch, T.; Bayer, J.; Bechini, R.; Belenguer, T.; Bellotti, R.; Belov, K.; Berlind, A. A.; Bertaina, M.; Biermann, P. L.; Biktemerova, S.; Blaksley, C.; Blanc, N.; Błȩcki, J.; Blin-Bondil, S.; Blümer, J.; Bobik, P.; Bogomilov, M.; Bonamente, M.; Briggs, M. S.; Briz, S.; Bruno, A.; Cafagna, F.; Campana, D.; Capdevielle, J.-N.; Caruso, R.; Casolino, M.; Cassardo, C.; Castellinic, G.; Catalano, C.; Catalano, G.; Cellino, A.; Chikawa, M.; Christl, M. J.; Cline, D.; Connaughton, V.; Conti, L.; Cordero, G.; Crawford, H. J.; Cremonini, R.; Csorna, S.; Dagoret-Campagne, S.; de Castro, A. J.; De Donato, C.; de la Taille, C.; De Santis, C.; del Peral, L.; Dell'Oro, A.; De Simone, N.; Di Martino, M.; Distratis, G.; Dulucq, F.; Dupieux, M.; Ebersoldt, A.; Ebisuzaki, T.; Engel, R.; Falk, S.; Fang, K.; Fenu, F.; Fernández-Gómez, I.; Ferrarese, S.; Finco, D.; Flamini, M.; Fornaro, C.; Franceschi, A.; Fujimoto, J.; Fukushima, M.; Galeotti, P.; Garipov, G.; Geary, J.; Gelmini, G.; Giraudo, G.; Gonchar, M.; González Alvarado, C.; Gorodetzky, P.; Guarino, F.; Guzmán, A.; Hachisu, Y.; Harlov, B.; Haungs, A.; Hernández Carretero, J.; Higashide, K.; Ikeda, D.; Ikeda, H.; Inoue, N.; Inoue, S.; Insolia, A.; Isgrò, F.; Itow, Y.; Joven, E.; Judd, E. G.; Jung, A.; Kajino, F.; Kajino, T.; Kaneko, I.; Karadzhov, Y.; Karczmarczyk, J.; Karus, M.; Katahira, K.; Kawai, K.; Kawasaki, Y.; Keilhauer, B.; Khrenov, B. A.; Kim, J.-S.; Kim, S.-W.; Kim, S.-W.; Kleifges, M.; Klimov, P. A.; Kolev, D.; Kreykenbohm, I.; Kudela, K.; Kurihara, Y.; Kusenko, A.; Kuznetsov, E.; Lacombe, M.; Lachaud, C.; Lee, J.; Licandro, J.; Lim, H.; López, F.; Maccarone, M. C.; Mannheim, K.; Maravilla, D.; Marcelli, L.; Marini, A.; Martinez, O.; Masciantonio, G.; Mase, K.; Matev, R.; Medina-Tanco, G.; Mernik, T.; Miyamoto, H.; Miyazaki, Y.; Mizumoto, Y.; Modestino, G.; Monaco, A.; Monnier-Ragaigne, D.; Morales de los Ríos, J. A.; Moretto, C.; Morozenko, V. S.; Mot, B.; Murakami, T.; Murakami, M. Nagano; Nagata, M.; Nagataki, S.; Nakamura, T.; Napolitano, T.; Naumov, D.; Nava, R.; Neronov, A.; Nomoto, K.; Nonaka, T.; Ogawa, T.; Ogio, S.; Ohmori, H.; Olinto, A. V.; Orleański, P.; Osteria, G.; Panasyuk, M. I.; Parizot, E.; Park, I. H.; Park, H. W.; Pastircak, B.; Patzak, T.; Paul, T.; Pennypacker, C.; Perez Cano, S.; Peter, T.; Picozza, P.; Pierog, T.; Piotrowski, L. W.; Piraino, S.; Plebaniak, Z.; Pollini, A.; Prat, P.; Prévôt, G.; Prieto, H.; Putis, M.; Reardon, P.; Reyes, M.; Ricci, M.; Rodríguez, I.; Rodríguez Frías, M. D.; Ronga, F.; Roth, M.; Rothkaehl, H.; Roudil, G.; Rusinov, I.; Rybczyński, M.; Sabau, M. D.; Sáez-Cano, G.; Sagawa, H.; Saito, A.; Sakaki, N.; Sakata, M.; Salazar, H.; Sánchez, S.; Santangelo, A.; Santiago Crúz, L.; Sanz Palomino, M.; Saprykin, O.; Sarazin, F.; Sato, H.; Sato, M.; Schanz, T.; Schieler, H.; Scotti, V.; Segreto, A.; Selmane, S.; Semikoz, D.; Serra, M.; Sharakin, S.; Shibata, T.; Shimizu, H. M.; Shinozaki, K.; Shirahama, T.; Siemieniec-Oziȩbło, G.; Silva López, H. H.; Sledd, J.; Słomińska, K.; Sobey, A.; Sugiyama, T.; Supanitsky, D.; Suzuki, M.; Szabelska, B.; Szabelski, J.; Tajima, F.; Tajima, N.; Tajima, T.; Takahashi, Y.; Takami, H.; Takeda, M.; Takizawa, Y.; Tenzer, C.; Tibolla, O.; Tkachev, L.; Tokuno, H.; Tomida, T.; Tone, N.; Toscano, S.; Trillaud, F.; Tsenov, R.; Tsunesada, Y.; Tsuno, K.; Tymieniecka, T.; Uchihori, Y.; Unger, M.; Vaduvescu, O.; Valdés-Galicia, J. F.; Vallania, P.; Valore, L.; Vankova, G.; Vigorito, C.; Villaseñor, L.; von Ballmoos, P.; Wada, S.; Watanabe, J.; Watanabe, S.; Watts, J.; Weber, M.; Weiler, T. J.; Wibig, T.; Wiencke, L.; Wille, M.; Wilms, J.; Włodarczyk, Z.; Yamamoto, T.; Yamamoto, Y.; Yang, J.; Yano, H.; Yashin, I. V.; Yonetoku, D.; Yoshida, K.; Yoshida, S.; Young, R.; Zotov, M. Yu.; Zuccaro Marchi, A.

    2015-11-01

    EUSO-Balloon is a pathfinder for JEM-EUSO, the Extreme Universe Space Observatory which is to be hosted on-board the International Space Station. As JEM-EUSO is designed to observe Ultra-High Energy Cosmic Rays (UHECR)-induced Extensive Air Showers (EAS) by detecting their ultraviolet light tracks "from above", EUSO-Balloon is a nadir-pointing UV telescope too. With its Fresnel Optics and Photo-Detector Module, the instrument monitors a 50 km2 ground surface area in a wavelength band of 290-430 nm, collecting series of images at a rate of 400,000 frames/sec. The objectives of the balloon demonstrator are threefold: a) perform a full end-to-end test of a JEM-EUSO prototype consisting of all the main subsystems of the space experiment, b) measure the effective terrestrial UV background, with a spatial and temporal resolution relevant for JEM-EUSO. c) detect tracks of ultraviolet light from near space for the first time. The latter is a milestone in the development of UHECR science, paving the way for any future space-based UHECR observatory. On August 25, 2014, EUSO-Balloon was launched from Timmins Stratospheric Balloon Base (Ontario, Canada) by the balloon division of the French Space Agency CNES. From a float altitude of 38 km, the instrument operated during the entire astronomical night, observing UV-light from a variety of ground-covers and from hundreds of simulated EASs, produced by flashers and a laser during a two-hour helicopter under-flight.

  10. Radiofrequency catheter ablation versus balloon cryoablation of atrial fibrillation: markers of myocardial damage, inflammation, and thrombogenesis.

    PubMed

    Antolič, Bor; Pernat, Andrej; Cvijić, Marta; Žižek, David; Jan, Matevž; Šinkovec, Matjaž

    2016-07-01

    Evidence from animal and human studies suggests that cryoablation might be associated with a lesser inflammatory response and activation of coagulation compared with radiofrequency ablation. The study was aimed at comparing the effect of cryoballoon and radiofrequency catheter ablation of paroxysmal atrial fibrillation on markers of myocardial damage, inflammation, and activation of coagulation. Forty-one patients received either cryoballoon (n = 23) or radiofrequency (n = 18) ablation of atrial fibrillation. We measured troponin I, high-sensitivity CRP, and interleukin 6 at baseline from the cubital vein, and from the right and left atrium before and after ablation, and from the cubital vein the following day. Prothrombin fragments 1 + 2, soluble P‑selectin, and D‑dimer were measured before and after ablation from both atria. We observed higher troponin I release in the cryoballoon than in the radiofrequency group (7.01 mcg/l (interquartile range [IQR]: 5.30-9.09) vs 2.32 mcg/l (IQR: 1.45-2.98), p < 0.001). The levels of inflammatory markers (high-sensitivity CRP and interleukin 6) in the two groups were comparable, as were the levels of markers of coagulation activation. Procedure duration, fluoroscopy times, and mid-term success (23 months, IQR 7-32) of the two groups were also comparable. Cryoballoon ablation of atrial fibrillation causes more significant myocardial damage, that is, more extensive ablation lesions, compared with radiofrequency catheter ablation. However, no major differences between these two ablation techniques with regard to the inflammatory response and activation of the coagulation system were observed.

  11. Two Tethered Balloon Systems

    NASA Technical Reports Server (NTRS)

    Youngbluth, Otto; Owens, Thomas L.; Storey, Richard W.

    1990-01-01

    Systems take meteorological measurements for variety of research projects. Report describes work done by NASA Langley Research Center in atmospheric research using tethered balloon systems composed of commercially available equipment. Two separate tethered balloon systems described in report have payloads and configurations tailored to requirements of specific projects. Each system capable of measuring atmospheric parameter or species in situ and then telemetering this data in real time to ground station. Meteorological data and concentration of ozone typically measured. Indicates instrumented tethered balloon systems have distinct advantages over other systems for gathering data on troposphere.

  12. Catheter-based high-intensity ultrasound for epicardial ablation of the left ventricle: device design and in vivo feasiblity

    NASA Astrophysics Data System (ADS)

    Salgaonkar, Vasant A.; Nazer, Babak; Jones, Peter D.; Tanaka, Yasuaki; Martin, Alastair; Ng, Bennett; Duggirala, Srikant; Diederich, Chris J.; Gerstenfeld, Edward P.

    2015-03-01

    The development and in vivo testing of a high-intensity ultrasound thermal ablation catheter for epicardial ablation of the left ventricle (LV) is presented. Scar tissue can occur in the mid-myocardial and epicardial space in patients with nonischemic cardiomyopathy and lead to ventricular tachycardia. Current ablation technology uses radiofrequency energy, which is limited epicardially by the presence of coronary vessels, phrenic nerves, and fat. Ultrasound energy can be precisely directed to deliver targeted deep epicardial ablation while sparing intervening epicardial nerve and vessels. The proof-of-concept ultrasound applicators were designed for sub-xyphoid access to the pericardial space through a steerable 14-Fr sheath. The catheter consists of two rectangular planar transducers, for therapy (6.4 MHz) and imaging (5 MHz), mounted at the tip of a 3.5-mm flexible nylon catheter coupled and encapsulated within a custom-shaped balloon for cooling. Thermal lesions were created in the LV in a swine (n = 10) model in vivo. The ultrasound applicator was positioned fluoroscopically. Its orientation and contact with the LV were verified using A-mode imaging and a radio-opaque marker. Ablations employed 60-s exposures at 15 - 30 W (electrical power). Histology indicated thermal coagulation and ablative lesions penetrating 8 - 12 mm into the left ventricle on lateral and anterior walls and along the left anterior descending artery. The transducer design enabled successful sparing from the epicardial surface to 2 - 4 mm of intervening ventricle tissue and epicardial fat. The feasibility of targeted epicardial ablation with catheter-based ultrasound was demonstrated.

  13. Mobile, high-wind, balloon-launching apparatus

    NASA Technical Reports Server (NTRS)

    Rust, W. David; Marshall, Thomas C.

    1989-01-01

    In order to place instruments for measuring meteorological and electrical parameters into thunderstorms, an inexpensive apparatus has been developed which makes it possible to inflate, transport, and launch balloons in high winds. The launching apparatus is a cylinder of bubble plastic that is made by joining the sides of the cylinder together with a velcro rip strip. A balloon is launched by pulling the rip strip rapidly. This allows the balloon to pop upward into the ambient low-level wind and carry its instrumentation aloft. Different-sized launch tubes are constructed to accommodate particular sizes of balloons. Balloons have been launched in winds of about 20 m/s.

  14. THE MECHANISM OF LESION FORMATION BY FOCUSED ULTRASOUND ABLATION CATHETER FOR TREATMENT OF ATRIAL FIBRILLATION

    PubMed Central

    Sinelnikov, Y.D.; Fjield, T.; Sapozhnikov, O.A.

    2009-01-01

    The application of therapeutic ultrasound for the treatment of atrial fibrillation (AF) is investigated. The results of theoretical and experimental investigation of ultrasound ablation catheter are presented. The major components of the catheter are the high power cylindrical piezoelectric element and parabolic balloon reflector. Thermal elevation in the ostia of pulmonary veins is achieved by focusing the ultrasound beam in shape of a torus that transverses the myocardial tissue. High intensity ultrasound heating in the focal zone results in a lesion surrounding the pulmonary veins that creates an electrical conduction blocks and relief from AF symptoms. The success of the ablation procedure largely depends on the correct choice of reflector geometry and ultrasonic power. We present a theoretical model of the catheter’s acoustic field and bioheat transfer modeling of cardiac lesions. The application of an empirically derived relation between lesion formation and acoustic power is shown to correlate with the experimental data. Developed control methods combine the knowledge of theoretical acoustics and the thermal lesion formation simulations with experiment and thereby establish rigorous dosimetry that contributes to a safe and effective ultrasound ablation procedure. PMID:20161431

  15. Universal stratospheric balloon gradiometer

    NASA Astrophysics Data System (ADS)

    Tsvetkov, Yury; Filippov, Sergey; Brekhov, Oleg; Nikolaev, Nikolay

    The study of the interior structure of the Earth and laws of its evolution is one of the most difficult problems of natural science. Among the geophysical fields the anomaly magnetic field is one of the most informational in questions of the Earth’s crust structure. Many important parameters of an environment are expedient for measuring at lower altitudes, than satellite ones. So, one of the alternatives is stratospheric balloon survey. The balloon flight altitudes cover the range from 20 to 50 km. At such altitudes there are steady zone air flows due to which the balloon flight trajectories can be of any direction, including round-the-world (round-the-pole). For investigation of Earth's magnetic field one of the examples of such sounding system have been designed, developed and maintained at IZMIRAN and MAI during already about 25 years. This system consists of three instrumental containers uniformly placed along a vertical 6 km line. Up today this set has been used only for geomagnetic purposes. So we describe this system on example of the measuring of the geomagnetic field gradient. System allows measuring a module and vertical gradient of the geomagnetic field along the whole flight trajectory and so one’s name is - stratospheric balloon magnetic gradiometer (SMBG). The GPS-receivers, located in each instrumental container, fix the flight coordinates to within several tens meters. Process of SBMG deployment, feature of the exit of rope from the magazine at the moment of balloon launching has been studied. Used magazine is cellular type. The hodograph of the measuring base of SBMG and the technique of correction of the deviations of the measuring base from the vertical line (introduction of the amendments for the deviation) during the flight have been investigated. It is shown that estimation of the normal level of values of the vertical gradient of the geomagnetic field is determined by the accuracy of determining the length of the measuring base SBMG

  16. Fabrication of Small Caliber Stent-grafts Using Electrospinning and Balloon Expandable Bare Metal Stents.

    PubMed

    Uthamaraj, Susheil; Tefft, Brandon J; Jana, Soumen; Hlinomaz, Ota; Kalra, Manju; Lerman, Amir; Dragomir-Daescu, Dan; Sandhu, Gurpreet S

    2016-10-26

    Stent-grafts are widely used for the treatment of various conditions such as aortic lesions, aneurysms, emboli due to coronary intervention procedures and perforations in vasculature. Such stent-grafts are manufactured by covering a stent with a polymer membrane. An ideal stent-graft should have a biocompatible stent covered by a porous, thromboresistant, and biocompatible polymer membrane which mimics the extracellular matrix thereby promoting injury site healing. The goal of this protocol is to manufacture a small caliber stent-graft by encapsulating a balloon expandable stent within two layers of electrospun polyurethane nanofibers. Electrospinning of polyurethane has been shown to assist in healing by mimicking native extracellular matrix, thereby promoting endothelialization. Electrospinning polyurethane nanofibers on a slowly rotating mandrel enabled us to precisely control the thickness of the nanofibrous membrane, which is essential to achieve a small caliber balloon expandable stent-graft. Mechanical validation by crimping and expansion of the stent-graft has shown that the nanofibrous polyurethane membrane is sufficiently flexible to crimp and expand while staying patent without showing any signs of tearing or delamination. Furthermore, stent-grafts fabricated using the methods described here are capable of being implanted using a coronary intervention procedure using standard size guide catheters.

  17. Fabrication of Small Caliber Stent-grafts Using Electrospinning and Balloon Expandable Bare Metal Stents

    PubMed Central

    Uthamaraj, Susheil; Tefft, Brandon J.; Jana, Soumen; Hlinomaz, Ota; Kalra, Manju; Lerman, Amir; Dragomir-Daescu, Dan; Sandhu, Gurpreet S.

    2016-01-01

    Stent-grafts are widely used for the treatment of various conditions such as aortic lesions, aneurysms, emboli due to coronary intervention procedures and perforations in vasculature. Such stent-grafts are manufactured by covering a stent with a polymer membrane. An ideal stent-graft should have a biocompatible stent covered by a porous, thromboresistant, and biocompatible polymer membrane which mimics the extracellular matrix thereby promoting injury site healing. The goal of this protocol is to manufacture a small caliber stent-graft by encapsulating a balloon expandable stent within two layers of electrospun polyurethane nanofibers. Electrospinning of polyurethane has been shown to assist in healing by mimicking native extracellular matrix, thereby promoting endothelialization. Electrospinning polyurethane nanofibers on a slowly rotating mandrel enabled us to precisely control the thickness of the nanofibrous membrane, which is essential to achieve a small caliber balloon expandable stent-graft. Mechanical validation by crimping and expansion of the stent-graft has shown that the nanofibrous polyurethane membrane is sufficiently flexible to crimp and expand while staying patent without showing any signs of tearing or delamination. Furthermore, stent-grafts fabricated using the methods described here are capable of being implanted using a coronary intervention procedure using standard size guide catheters. PMID:27805589

  18. The Great Balloon Controversy.

    ERIC Educational Resources Information Center

    Chase, Valerie

    1989-01-01

    Discusses the harmful effects of balloon launches and the dumping of plastic debris into oceans. Cites several examples of plastic materials being discovered inside the bodies of sick and/or dead marine animals. Offers alternative activities to releasing balloons into the atmosphere. (RT)

  19. Exploring relationships of catheter-associated urinary tract infection and blockage in people with long-term indwelling urinary catheters.

    PubMed

    Wilde, Mary H; McMahon, James M; Crean, Hugh F; Brasch, Judith

    2017-09-01

    To describe and explore relationships among catheter problems in long-term indwelling urinary catheter users, including excess healthcare use for treating catheter problems. Long-term urinary catheter users experience repeated problems with catheter-related urinary tract infection and blockage of the device, yet little has been reported of the patterns and relationships among relevant catheter variables. Secondary data analysis was conducted from a sample in a randomised clinical trial, using data from the entire sample of 202 persons over 12 months' participation. Descriptive statistics were used to characterise the sample over time. Zero-inflated negative binomial models were employed for logistic regressions to evaluate predictor variables of the presence/absence and frequencies of catheter-related urinary tract infection and blockage. Catheter-related urinary tract infection was marginally associated with catheter blockage. Problems reported at least once per person in the 12 months were as follows: catheter-related urinary tract infection 57%, blockage 34%, accidental dislodgment 28%, sediment 87%, leakage (bypassing) 67%, bladder spasms 59%, kinks/twists 42% and catheter pain 49%. Regression analysis demonstrated that bladder spasms were significantly related to catheter-related urinary tract infection and sediment amount, and catheter leakages were marginally significantly and positively related to catheter-related urinary tract infection. Frequencies of higher levels of sediment and catheter leakage were significantly associated with higher levels of blockage, and being female was associated with fewer blockages. Persons who need help with eating (more disabled) were also more likely to have blockages. Catheter-related urinary tract infection and blockage appear to be related and both are associated with additional healthcare expenditures. More research is needed to better understand how to prevent adverse catheter outcomes and patterns of problems in

  20. Rational choice of peritoneal dialysis catheter.

    PubMed

    Dell'Aquila, Roberto; Chiaramonte, Stefano; Rodighiero, Maria Pia; Spanó, Emilia; Di Loreto, Pierluigi; Kohn, Catalina Ocampo; Cruz, Dinna; Polanco, Natalia; Kuang, Dingwei; Corradi, Valentina; De Cal, Massimo; Ronco, Claudio

    2007-06-01

    The peritoneal catheter should be a permanent and safe access to the peritoneal cavity. Catheter-related problems are often the cause of permanent transfer to hemodialysis (HD) in up to 20% of peritoneal dialysis (PD) patients; in some cases, these problems require a temporary period on HD. Advances in connectology have reduced the incidence of peritonitis, and so catheter-related complications during PD have become a major concern. In the last few years, novel techniques have emerged in the field of PD: new dialysis solutions, better connectology, and cyclers for automated PD. However, extracorporeal dialysis has continued to improve in terms of methods and patient survival, but PD has failed to do so. The main reason is that peritoneal access has remained problematical. The peritoneal catheter is the major obstacle to wide-spread use of PD. Overcoming catheter-related problems means giving a real chance to development of the peritoneal technique. Catheters should be as efficient, safe, and acceptable as possible. Since its introduction in the mid-1960s, the Tenckhoff catheter has not become obsolete: dozens of new models have been proposed, but none has significantly reduced the pre-dominance of the first catheter. No convincing prospective data demonstrate the superiority of any peritoneal catheter, and so it seems that factors other than choice of catheter are what affect survival and complication rates. Efforts to improve peritoneal catheter survival and complication rates should probably focus on factors other than the choice of catheter. The present article provides an overview of the characteristics of the best-known peritoneal catheters.

  1. Current trends of balloon laryngoplasty in Thailand.

    PubMed

    Moungthong, Greetha; Bunbanjerdsuk, Sacarin; Wright, Nida; Sathavornmanee, Thanakrit; Setabutr, Dhave

    2017-06-01

    To describe the current trend in balloon laryngoplasty usage and experience by practicing otolaryngologists in Thailand. Anonymous 11 question online and paper survey of otolaryngologists on their current balloon laryngoplasty practices. Current practices and experience in balloon laryngoplasty were queried with multiple choice and open-ended questions. Laser use is the most commonly utilized instrument to treat airway stenosis in Thailand. 86% of respondents do not have experience with balloon dilatation; yet, almost half (47.6%) report they perform a minimum of five airway surgeries per year. Most respondents had been in practice for less than 6 years (41%) and reported that they did not have exposure to balloon use during residency training. The largest barrier reported for the use of balloon instrumentation in the airway is inexperience (44.4%) followed by cost (38.3%), yet most feel that treatment in airway stenosis could benefit by usage of balloons (95.5%). Most otolaryngologists in Thailand do not have experience with the use of balloon dilatation and lack of exposure remains the largest barrier to its use. Otolaryngologists in Thailand feel that increased usage of balloons in the airway could improve airway stenosis treatment in the country.

  2. Reference level winds from balloon platforms

    NASA Technical Reports Server (NTRS)

    Lally, Vincent E.

    1985-01-01

    The superpressure balloon was developed to provide a method of obtaining global winds at all altitudes from 5 to 30 km. If a balloon could be made to fly for several weeks at a constant altitude, and if it could be tracked accurately on its global circuits, the balloon would provide a tag for the air parcel in which it was embedded. The Lagrangian data on the atmospheric circulation would provide a superior data input to the numerical model. The Global Atmospheric Research Program (GARP) was initiated in large part based on the promise of this technique coupled with free-floating ocean buoys and satellite radiometers. The initial name proposed by Charney for GARP was SABABURA 'SAtellite BAlloon BUoy RAdiometric system' (Charney, 1966). However, although the superpressure balloon exceeded its designers' expectations for flight duration in the stratosphere (longest flight duration of 744 days), flight duration below 10 km was limited by icing in super-cooled clouds to a few days. The balloon was relegated to a secondary role during the GARP Special Observing Periods. The several major superpressure balloon programs for global wind measurement are described as well as those new developments which make the balloon once again an attractive vehicle for measurement of global winds as a reference and bench-mark system for future satellite systems.

  3. Echogenic Catheters and Embryo Transfer Standardization.

    PubMed

    Urbina, Maria Teresa; Benjamin, Isaac; Medina, Randolfo; Lerner, Jorge

    2015-05-01

    1.To describe the standardization process and protocols of the ET method at our center. 2.To compare the performance of non-echogenic catheters with echogenic catheters during ultrasound-guided ET. Retrospective analysis of 2630 ET performed at UNIFERTES during 1997-2014, to describe standardization process and to compare the percentage of difficult ET between echogenic and non-echogenic catheters. We tested 17 non-echogenic and three echogenic catheters. Many variables were associated with the ease of ET: informed patients, waiting time for the procedure, speculum use, clinical touch, uterine contractions, cervical mucus removal, presence of blood before or after the procedure, full bladder, ultrasound guidance, uterocervical angle, mock transfer, catheter type (soft or hard, echogenic or non-echogenic, with stylet or not), catheter loading technique, duration of embryo loading (time interval since the embryos were removed from the incubator for loading until the catheter is passed to the physician), transfer procedure (time interval from the catheter was handed to the physician until the embryos were discharged in the uterus), catheter tip placement, retained embryos, bed rest after ET, operator´s proficiency. The diversity of catheters used and the percentage of difficult transfers decrease as the use of echogenic catheters increases. This process is necessary to minimize variation, ensure high quality, safe and evidence-based practice, and improve outcomes. To standardize the ET method allowed a quicker and easier transfer. The use of echogenic catheters simplified ET procedures guided by abdominal ultrasound.

  4. Suprapubic cystostomy using optical urethrotome in female patients.

    PubMed

    Sawant, Ajit Somaji; Patwardhan, Sujata K; Attar, Mohammad Ismail; Varma, Radheshyam; Bansal, Ujjwal

    2009-08-01

    In many female patients for lower urinary tract reconstructive procedures, a suprapubic cystostomy along with perurethral catheter is required for urinary diversion. We describe a new and simple method of intraoperative suprapubic catheter placement using optical urethrotome wherein distension of bladder is not required. A total of 26 patients underwent suprapubic catheter placement intraoperatively with the aid of Sachse' optical urethrotome and its outer sheath from January 2005 to May 2008. A 16F Foley catheter could be successfully placed suprapubically in all patients with this method. There were no complications like injury to intraabdominal viscera, retropubic hematoma, hematuria, or catheter dislodgement. We describe a new method of intraoperative suprapubic catheter placement in female patients that is minimally invasive, technically safe, simple, and effective, and does not require bladder distension.

  5. Modelling Hot Air Balloons.

    ERIC Educational Resources Information Center

    Brimicombe, M. W.

    1991-01-01

    A macroscopic way of modeling hot air balloons using a Newtonian approach is presented. Misleading examples using a car tire and the concept of hot air rising are discussed. Pressure gradient changes in the atmosphere are used to explain how hot air balloons work. (KR)

  6. Solar research with stratospheric balloons

    NASA Astrophysics Data System (ADS)

    Vázquez, Manuel; Wittmann, Axel D.

    Balloons, driven by hot air or some gas lighter than air, were the first artificial machines able to lift payloads (including humans) from the ground. After some pioneering flights the study of the physical properties of the terrestrial atmosphere constituted the first scientific target. A bit later astronomers realized that the turbulence of the atmospheric layers above their ground-based telescopes deteriorated the image quality, and that balloons were an appropriate means to overcome, total or partially, this problem. Some of the most highly-resolved photographs and spectrograms of the sun during the 20th century were actually obtained by balloon-borne telescopes from the stratosphere. Some more recent projects of solar balloon astronomy will also be described.

  7. Retrieval of a detached transseptal sheath tip from a right pulmonary artery branch following catheter ablation.

    PubMed

    Schricker, Amir A; Feld, Gregory K; Tsimikas, Sotirios

    2015-11-15

    Transseptal introducer sheaths are being used with increasing frequency for left-sided arrhythmia ablations and structural heart disease interventions. Sheath tip detachment and embolization is an uncommon but known complication, and several sheaths have been recalled due to such complications. We report a unique case of a fractured transseptal sheath tip that embolized to a branch of the right pulmonary artery in a patient who had undergone ablation of a left-sided atypical atrial flutter. During final removal of one of the two long 8.5-French SL1 transseptal sheaths used routinely as part of the ablation, the radiopaque tip of the sheath fractured and first embolized to the right atrium and subsequently to a secondary right pulmonary artery branch. Using techniques derived from percutaneous interventional approaches, including a multipurpose catheter, coronary guidewire, and monorail angioplasty balloon, the sheath tip was successfully wired through its inner lumen, trapped from the inside with the balloon, and removed from the body via a large femoral vein sheath, without complications. The approach detailed in this case may guide future cases and circumvent urgent surgical intervention. © 2015 Wiley Periodicals, Inc.

  8. Dense Accumulation of Lipiodol Emulsion in Hepatocellular Carcinoma Nodule during Selective Balloon-occluded Transarterial Chemoembolization: Measurement of Balloon-occluded Arterial Stump Pressure

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Irie, Toshiyuki, E-mail: toshiyuki.irie.rq@hitachi.com; Kuramochi, Masashi, E-mail: masashi.kuramochi.sh@hitachi.com; Takahashi, Nobuyuki, E-mail: nbyktakahashiodn@yahoo.co.jp

    2013-06-15

    Purpose. To reveal the mechanism of dense accumulation of lipiodol emulsion (LE) in hepatocellular carcinoma (HCC) during selective balloon-occluded transarterial chemoembolization (B-TACE). Methods. Balloon-occluded arterial stump pressure (BOASP) at the embolization portion was measured during selective B-TACE for 43 nodules in 42 patients. Fluoroscopy and digital subtraction angiography were prospectively observed during selective B-TACE to note whether dense LE accumulation in HCC occurred. The LE concentration ratio of HCC to embolized liver parenchyma (LECHL ratio) was also calculated for each treatment on the basis of the computed tomographic scan obtained immediately after selective B-TACE. The relationships between degree of LEmore » accumulation and the BOASP, as well as the LECHL ratio, were analyzed. Results. Arterial flow beyond the catheter tip was maintained even after balloon inflation. In 39 of 43 treatments, LE inflow into the nontumorous liver parenchyma ceased immediately after LE droplets were filled in arteries of the nontumorous liver parenchyma while LE inflow into the HCC nodule continued (group 1). More dense LE accumulation in HCC nodule was obtained in these 39 treatments. In four treatments, LE inflow both into the nontumorous liver parenchyma and into the HCC nodule continued, and no dense LE accumulation in HCC nodule was observed (group 2). In these four treatments, thick anastomotic vessels with collateral artery were noted. The BOASP in group 1 was (mean {+-} SD) 33.8 {+-} 12.8 mmHg (range 13-64 mmHg) and that in group 2 was 92.3 {+-} 7.4 mmHg (range 83-100 mmHg). There was a statistically significant difference in BOASP between groups (p = 0.00004, Welch's t test). The LECHL ratio in group 1 was 18.3 {+-} 13.9 (range 2.9-54.2) and that in group 2 was 2.6 {+-} 1.1 (range 1.7-4.2). There was a statistically significant difference in the LECHL ratio between the groups (p = 0.000034, Welch's t test). Conclusion. Selective B

  9. Hot Balloon Versus Cryoballoon Ablation for Atrial Fibrillation: Lesion Characteristics and Middle-Term Outcomes.

    PubMed

    Nagashima, Koichi; Okumura, Yasuo; Watanabe, Ichiro; Nakahara, Shiro; Hori, Yuichi; Iso, Kazuki; Watanabe, Ryuta; Arai, Masaru; Wakamatsu, Yuji; Kurokawa, Sayaka; Mano, Hiroaki; Nakai, Toshiko; Ohkubo, Kimie; Hirayama, Atsushi

    2018-05-01

    Hot balloon ablation (HBA) and cryoballoon ablation (CBA) were developed to simplify ablation for atrial fibrillation. Because the lesion characteristics and efficacy of these balloon modalities have not been clarified, we compared lesion characteristics and outcomes of HBA and CBA. Of 165 consecutive patients who underwent initial catheter ablation for atrial fibrillation, 74 propensity scorematched (37 HBA and 37 CBA) patients were included in our study. Patients' clinical characteristics, including age, sex, body mass index, atrial fibrillation subtype, CHA 2 DS 2 -VASc score, and left atrial dimension, were similar between the 2 groups. Touch-up radiofrequency ablation was required for residual/dormant pulmonary vein conduction in 52% of the patients with HBA versus 24% of the patients with CBA ( P =0.02) and often in the anterior aspect of the left superior pulmonary vein after HBA (41%) versus the inferior aspect of the inferior pulmonary veins after CBA (22%). HBA lesions were smaller than CBA lesions (23.8±7.9 versus 33.5±14.5 cm 2 ; P =0.0007). Similar results were observed when lesions in each pulmonary vein were compared between groups. Twentyfour hours after the procedure, serum levels of the cardiac biomarkers, including troponin-T, creatine kinase, and creatine kinase-MB, were higher in the HBA group than in the CBA group. Atrial fibrillation recurrence did not differ between the groups within 6 (3% versus 11%; P =0.36) or 12 months (16% versus 16%; P =1.00). Although HBA lesions appear to be smaller than CBA lesions, middle-term outcomes are not statistically different between these balloon modalities. © 2018 American Heart Association, Inc.

  10. Central venous catheter-associated bloodstream infections in a pediatric intensive care unit: effect of the location of catheter insertion.

    PubMed

    Krishnaiah, Anil; Soothill, James; Wade, Angie; Mok, Quen Q; Ramnarayan, Padmanabhan

    2012-05-01

    To compare the rate of central venous catheter-associated bloodstream infections between pediatric intensive care unit admissions where central venous catheters were inserted within the same hospital (internal central venous catheters) and those where central venous catheters were inserted before transfer from other hospitals (external central venous catheters). Retrospective analysis of prospectively collected data. A tertiary care pediatric intensive care unit in London, UK. Consecutive pediatric intensive care unit admissions between May 2007 and March 2009. None. Catheter-associated bloodstream infections were identified using a widely accepted surveillance definition. The rate and time to occurrence of catheter-associated bloodstream infection were compared between internal and external nontunneled central venous catheters. A multilevel Cox-regression model was used to study the association between location of central venous catheter insertion and time to catheter-associated bloodstream infection. In total, 382 central venous catheters were studied (245 internal; 137 external) accounting for a total of 1,737 central venous catheter days. There was a higher catheter-associated bloodstream infection incidence density among external central venous catheters (23.1 [95% confidence interval 11.0-35.2] vs. 9.7 [95% confidence interval 3.9-15.5] per 1,000 catheter-days). Multivariable analyses demonstrated higher infection risk with external central venous catheters (hazard ratio 2.65 [95% confidence interval 1.18-5.96]) despite adjustment for confounding variables. The rate of catheter-associated bloodstream infections in the pediatric intensive care unit is significantly affected by external insertion of the central venous catheter. Future interventions to reduce nosocomial infections on pediatric intensive care units will need to be specifically targeted at this high-risk patient group.

  11. Calculating Payload for a Tethered Balloon System

    Treesearch

    Charles D. Tangren

    1980-01-01

    A graph method to calculate payload for a tethered balloon system, with the supporting helium lift and payload equations. is described. The balloon system is designed to collect emissions data during the convective-lift and no-convective-lift phases of a forest fire. A description of the balloon system and a list of factors affecting balloon selection are included....

  12. [The role of the uretral catheter in the development of catheter- related urinary tract infection].

    PubMed

    Vasilyev, A O; Govorov, A V; Shiryaev, A A; Pushkar, D Yu

    2017-12-01

    The most common source of nosocomial infection is the urinary tract, especially if they it is drained with a urethral catheter. Catheter-associated urinary tract infections account for at least 80% of all complicated urinary tract infections and are the most common type of hospital-acquired infection. Intestinal microflora plays the leading role in the pathogenesis of catheter-associated urinary tract infections, whereas the most important risk factor for their development is the long duration of urinary catheter drainage. In the case of short-term and intermittent catheterization, routine antibiotic prophylaxis is not required, but if a patient develops clinically significant infection, antibiotic therapy is required followed by definitive therapy based on culture. Urethral catheters coated with antimicrobial substances and anti-inflammatory agents can significantly reduce the adhesion and migration of bacteria, thereby reducing the incidence of urinary tract infections. Despite this, the incidence of catheter-associated infection remains high. We have reviewed recent literature related to catheter-associated urinary tract infections and the best means of preventing this condition.

  13. A modified catheterization procedure to reduce bladder damage when collecting urine samples from Holstein cows.

    PubMed

    Tamura, Tetsuo; Nakamura, Hiroshi; Sato, Say; Seki, Makoto; Nishiki, Hideto

    2014-06-01

    This study proposed a modified procedure, using a small balloon catheter (SB catheter, 45 ml), for reducing bladder damage in cows. Holstein cows and the following catheters were prepared: smaller balloon catheter (XSB catheter; 30 ml), SB catheter and standard balloon catheter (NB catheter; 70 ml, as the commonly used, standard size). In experiment 1, each cow was catheterized. The occurrence of catheter-associated hematuria (greater than 50 RBC/HPF) was lower in the SB catheter group (0.0%, n=7) than in the NB catheter group (71.4%, n=7; P<0.05). In experiment 2, general veterinary parameters, urine pH, body temperature and blood values in cows were not affected before or after insertion of SB catheters (n=6). The incidence of urinary tract infection (UTI) was 3.0% per catheterized day (n=22). In experiment 3, feeding profiles, daily excretion of urinary nitrogen (P<0.05) and rate from nitrogen intake in urine (P<0.01), were higher with use of the SB catheter (n=13) than with the use of the vulva urine cup (n=18), indicating that using the SB catheter can provide accurate nutritional data. From this study, we concluded that when using an SB catheter, the following results occur; reduction in bladder damage without any veterinary risks and accuracy in regard to feeding parameters, suggesting this modified procedure using an SB catheter is a useful means of daily urine collection.

  14. A Modified Catheterization Procedure to Reduce Bladder Damage when Collecting Urine Samples from Holstein Cows

    PubMed Central

    TAMURA, Tetsuo; NAKAMURA, Hiroshi; SATO, Say; SEKI, Makoto; NISHIKI, Hideto

    2014-01-01

    ABSTRACT This study proposed a modified procedure, using a small balloon catheter (SB catheter, 45 ml), for reducing bladder damage in cows. Holstein cows and the following catheters were prepared: smaller balloon catheter (XSB catheter; 30 ml), SB catheter and standard balloon catheter (NB catheter; 70 ml, as the commonly used, standard size). In experiment 1, each cow was catheterized. The occurrence of catheter-associated hematuria (greater than 50 RBC/HPF) was lower in the SB catheter group (0.0%, n=7) than in the NB catheter group (71.4%, n=7; P<0.05). In experiment 2, general veterinary parameters, urine pH, body temperature and blood values in cows were not affected before or after insertion of SB catheters (n=6). The incidence of urinary tract infection (UTI) was 3.0% per catheterized day (n=22). In experiment 3, feeding profiles, daily excretion of urinary nitrogen (P<0.05) and rate from nitrogen intake in urine (P<0.01), were higher with use of the SB catheter (n=13) than with the use of the vulva urine cup (n=18), indicating that using the SB catheter can provide accurate nutritional data. From this study, we concluded that when using an SB catheter, the following results occur; reduction in bladder damage without any veterinary risks and accuracy in regard to feeding parameters, suggesting this modified procedure using an SB catheter is a useful means of daily urine collection. PMID:24561376

  15. Flight Qualification of the NASA's Super Pressure Balloon

    NASA Astrophysics Data System (ADS)

    Cathey, Henry; Said, Magdi; Fairbrother, Debora

    Designs of new balloons to support space science require a number of actual flights under various flight conditions to qualify them to as standard balloon flight offerings to the science community. Development of the new Super Pressure Balloon for the National Aeronautics and Space Administration’s Balloon Program Office has entailed employing new design, analysis, and production techniques to advance the state of the art. Some of these advances have been evolutionary steps and some have been revolutionary steps requiring a maturing understanding of the materials, designs, and manufacturing approaches. The NASA Super Pressure Balloon development end goal is to produce a flight vehicle that is qualified to carry a ton of science instrumentation, at an altitude greater than 33 km while maintaining a near constant pressure altitude for extended periods of up to 100 days, and at any latitude on the globe. The NASA’s Balloon Program Office has pursued this development in a carefully executed incremental approach by gradually increasing payload carrying capability and increasing balloon volume to reach these end goal. A very successful test flight of a ~200,700 m3 balloon was launch in late 2008 from Antarctica. This balloon flew for over 54 days at a constant altitude and circled the Antarctic continent almost three times. A larger balloon was flown from Antarctica in early 2011. This ~422,400 m3 flew at a constant altitude for 22 days making one circuit around Antarctica. Although the performance was nominal, the flight was terminated via command to recover high valued assets from the payload. The balloon designed to reach the program goals is a ~532,200 m3 pumpkin shaped Super Pressure Balloon. A test flight of this balloon was launched from the Swedish Space Corporation’s Esrange Balloon Launch Facilities near Kiruna, Sweden on 14 August, 2012. This flight was another success for this development program. Valuable information was gained from this short test

  16. [Urinary catheter biofilm infections].

    PubMed

    Holá, V; Růzicka, F

    2008-04-01

    Urinary tract infections, most of which are biofilm infections in catheterized patients, account for more than 40% of hospital infections. Bacterial colonization of the urinary tract and catheters causes not only infection but also other complications such as catheter blockage by bacterial encrustation, urolithiasis and pyelonephritis. About 50% of long-term catheterized patients face urinary flow obstruction due to catheter encrustation, but no measure is currently available to prevent it. Encrustation has been known either to result from metabolic dysfunction or to be of microbial origin, with urease positive bacterial species implicated most often. Infectious calculi account for about 15-20% of all cases of urolithiasis and are often associated with biofilm colonization of a long-term indwelling urinary catheter or urethral stent. The use of closed catheter systems is helpful in reducing such problems; nevertheless, such a system only delays the inevitable, with infections emerging a little later. Various coatings intended to prevent the bacterial adhesion to the surface of catheters and implants and thus also the emergence of biofilm infections, unfortunately, do not inhibit the microbial adhesion completely and permanently and the only reliable method for biofilm eradication remains the removal of the foreign body from the patient.

  17. Early Cosmic Ray Research with Balloons

    NASA Astrophysics Data System (ADS)

    Walter, Michael

    2013-06-01

    The discovery of cosmic rays by Victor Hess during a balloon flight in 1912 at an altitude of 5350 m would not have been possible without the more than one hundred years development of scientific ballooning. The discovery of hot air and hydrogen balloons and their first flights in Europe is shortly described. Scientific ballooning was mainly connected with activities of meteorologists. It was also the geologist and meteorologist Franz Linke, who probably observed first indications of a penetrating radiation whose intensity seemed to increase with the altitude. Karl Bergwitz and Albert Gockel were the first physicists studying the penetrating radiation during balloon flights. The main part of the article deals with the discovery of the extraterrestrial radiation by V. Hess and the confirmation by Werner Kolhörster.

  18. History and perspectives of scientific ballooning

    NASA Astrophysics Data System (ADS)

    Lefevre, Frank

    2001-08-01

    Prehistory: Robertson, Biot and Gay-Lussac; Glaisher and the first studies of the atmosphere; Flammarion. The rebirth of scientific ballooning: polyethylene and mylar vehicles at Minneapolis. Super-pressurized balloons. The CNES and the Nasa programs; meteorology, aeronomy and astronomy, The Eole program. The Venus and Mars balloons in the French-Soviet space program. The future.

  19. The sliding rail system (monorail): description of a new technique for intravascular instrumentation and its application to coronary angioplasty.

    PubMed

    Bonzel, T; Wollschläger, H; Kasper, W; Meinertz, T; Just, H

    1987-01-01

    The sliding rail technique is a new technique for intravascular instrumentation, especially coronary stenosis dilatation. The so-called monorail balloon catheter is the first device which can be used according to this technique. The monorail catheter has a single lumen shaft and only a short central tube within the distal balloon part. With the guidewire inserted into the tube, the balloon can be advanced or retracted on the guidewire as on a sliding rail. The most relevant improvements for coronary dilatation are steerability, contrast flow and rapid and easy exchangeability of balloon catheters and other intracoronary devices. These characteristics are felt to result in a more simple and time- and fluoroscopy-saving dilatation procedure. A special transfusion catheter may also improve procedural safety. The first clinical results in 69 patients with a success rate of 96%, an emergency bypass rate of two patients (one infarction) and a stenosis improvement of 58% confirm the theoretically conceived advantages.

  20. [Rotational stability of angiography catheters].

    PubMed

    Schröder, J; Weber, M

    1992-10-01

    Rotatory stability is a parameter that reflects the ability of a catheter to transmit a rotation applied at the outer end to the catheter tip for the purpose of selective probing. A method for measuring the rotatory stability is described, and the results of rotatory stability measurements of 70 different commercially available catheters are reported. There is an almost linear correlation between the rotatory stability and the difference between the respective fourth power of the external and internal diameter or, approximately, to the fourth power of the external diameter for catheters without wire reinforcement. With the same cross-sectional dimensions, the rotatory stability of teflon, polyethylene, and nylon catheters has an approximate ratio of 1:2:4. Wire reinforcement increases rotatory stability by an average factor of about 3. For catheters of calibers 5 F and 6 F, a correlation between the rotatory stability and the weight of the reinforcing wire mesh is apparent.

  1. Histopathology of balloon-dilation Eustachian tuboplasty.

    PubMed

    Kivekäs, Ilkka; Chao, Wei-Chieh; Faquin, William; Hollowell, Monica; Silvola, Juha; Rasooly, Tali; Poe, Dennis

    2015-02-01

    Surgical intervention of the Eustachian tube (ET) has become increasingly common in the past decade, and balloon dilation has shown promising results in recent studies. It is unclear how balloon dilation enhances ET function. Our aim was to evaluate histological changes in the ET's mucosal lumen comparing before balloon dilation, immediately after, and postoperatively. Case series. Thirteen patients with bilateral ET dysfunction were enrolled. Biopsies of the ET mucosa were obtained just before balloon dilation; immediately after; and in three cases, 5 to 12 weeks postoperatively. Specimens were retrospectively examined under light microscopy by two pathologists blinded to the clinical information and whether specimens were pre- or postballoon dilation. Preoperative biopsies were characterized by inflammatory changes within the epithelium and submucosal layer. Immediate response to balloon dilation was thinning of the mucosa, shearing of epithelium and crush injury to the submucosa, especially to lymphocytic infiltrates. Postoperative biopsies demonstrated healthy pseudocolumnar epithelium and replacement of lymphocytic infiltrate with a thinner layer of fibrous tissue. Reduction of inflammatory epithelial changes and submucosal inflammatory infiltrate appeared to be the principal result of balloon dilation. The balloon may shear or crush portions of inflamed epithelium but usually spared the basal layer, allowing for rapid healing. Additionally, it appeared to effectively crush lymphocytes and lymphocytic follicles that may become replaced with thinner fibrous scar. Histopathology of the ET undergoing balloon dilation demonstrated effects that could reduce the overall inflammatory burden and may contribute to clinical improvement in ET function. 4. © 2014 The American Laryngological, Rhinological and Otological Society, Inc.

  2. Effect of intra-aortic balloon pump on coronary blood flow during different balloon cycles support: A computer study.

    PubMed

    Aye, Thin Pa Pa; Htet, Zwe Lin; Singhavilai, Thamvarit; Naiyanetr, Phornphop

    2015-01-01

    Intra-aortic balloon pump (IABP) has been used in clinical treatment as a mechanical circulatory support device for patients with heart failure. A computer model is used to study the effect on coronary blood flow (CBF) with different balloon cycles under both normal and pathological conditions. The model of cardiovascular and IABP is developed by using MATLAB SIMULINK. The effect on coronary blood flow has been studied under both normal and pathological conditions using different balloon cycles (balloon off; 1:4; 1:2; 1:1). A pathological heart is implemented by reducing the left ventricular contractility. The result of this study shows that the rate of balloon cycles is related to the level of coronary blood flow.

  3. Balloon Angioplasty – The Legacy of Andreas Grüntzig, M.D. (1939–1985)

    PubMed Central

    Barton, Matthias; Grüntzig, Johannes; Husmann, Marc; Rösch, Josef

    2014-01-01

    In 1974, at the Medical Policlinic of the University of Zürich, German-born physician-scientist Andreas Grüntzig (1939–1985) for the first time applied a balloon-tipped catheter to re-open a severely stenosed femoral artery, a procedure, which he initially called “percutaneous transluminal dilatation”. Balloon angioplasty as a therapy of atherosclerotic vascular disease, for which Grüntzig and Charles T. Dotter (1920–1985) received a nomination for the Nobel Prize in Physiology or Medicine in 1978, became one of the most successful examples of translational medicine in the twentieth century. Known today as percutaneous transluminal angioplasty (PTA) in peripheral arteries or percutaneous transluminal coronary angioplasty (PTCA) or percutaneous coronary intervention (PCI) in coronary arteries, balloon angioplasty has become the method of choice to treat patients with acute myocardial infarction or occluded leg arteries. On the occasion of the 40th anniversary of balloon angioplasty, we summarize Grüntzig’s life and career in Germany, Switzerland, and the United States and also review the developments in vascular medicine from the 1890s to the 1980s, including Dotter’s first accidental angioplasty in 1963. The work of pioneers of catheterization, including Pedro L. Fariñas in Cuba, André F. Cournand in France, Werner Forssmann, Werner Porstmann and Eberhard Zeitler in Germany, António Egas Moniz and Reynaldo dos Santos in Portugal, Sven-Ivar Seldinger in Sweden, and Barney Brooks, Thomas J. Fogarty, Melvin P. Judkins, Richard K. Myler, Dickinson W. Richards, and F. Mason Sones in the United States, is discussed. We also present quotes by Grüntzig and excerpts from his unfinished autobiography, statements of Grüntzig’s former colleagues and contemporary witnesses, and have included hitherto unpublished historic photographs and links to archive recordings and historic materials. This year, on June 25, 2014, Andreas Grüntzig would have celebrated

  4. NASA balloon design and flight - Philosophy and criteria

    NASA Technical Reports Server (NTRS)

    Smith, I. S., Jr.

    1993-01-01

    The NASA philosophy and criteria for the design and flight of scientific balloons are set forth and discussed. The thickness of balloon films is standardized at 20.3 microns to isolate potential film problems, and design equations are given for specific balloon parameters. Expressions are given for: flight-stress index, total required thickness, cap length, load-tape rating, and venting-duct area. The balloon design criteria were used in the design of scientific balloons under NASA auspices since 1986, and the resulting designs are shown to be 95 percent effective. These results represent a significant increase in the effectiveness of the balloons and therefore indicate that the design criteria are valuable. The criteria are applicable to four balloon volume classes in combination with seven payload ranges.

  5. [Drug-coated Balloon Angioplasty in Femoropopliteal Arteries - Is There a Class Effect?

    PubMed

    Teichgräber, Ulf Karl-Martin; Klumb, Christof

    2017-10-01

    Aim Percutaneous transluminal angioplasty (PTA) is a well-accepted method to re-establish patency in stenotic and reoccluded vessels. One tool to improve results may be to use paclitaxel drug-coated balloon (DCB) catheters. This systematic review investigates whether there is a class effect among different DCBs. Methods The primary endpoint was "Freedom from Target Lesion Revascularisation" (FfTLR) after 12 months. A systematic literature search was performed in PubMed and risk of bias was assessed of the included trials. Efficacy of DCB vs. POBA (plain old balloon angioplasty) in binary outcomes was investigated with relative risks and number needed to treat (NNT). Results Ten trials including 1835 patients and investigating six different DCB were identified. A high risk of bias was found in these studies. There was a lower Late Lumen Loss at six months and a higher FfTLR and primary patency at one year after DCB-treatment. However, results varied greatly with NNTs ranging from three to thirty-three. Overall, there were no differences in ABI- and Rutherford-Outcome as well as incidence of adverse events. Conclusion Tested DCBs were able to improve PTA results at one year. There were large differences in efficacy between different DCB. A class effect cannot be confirmed yet. There is a risk of overestimating the effect of DCBs due to the high risk of bias in the included trials. Georg Thieme Verlag KG Stuttgart · New York.

  6. Bladder Morphology Using 2 Different Catheter Designs

    ClinicalTrials.gov

    2017-04-10

    Urologic Injuries; Urologic Diseases; Bladder Infection; Urinary Tract Infections; Mucosal Inflammation; Mucosal Infection; Bladder Injury; Catheter-Related Infections; Catheter Complications; Catheter; Infection (Indwelling Catheter); Pelvic Floor Disorders; Urinary Incontinence

  7. First-in-Man Experience with a Novel Catheter-Based Renal Denervation System of Ultrasonic Ablation in Patients with Resistant Hypertension.

    PubMed

    Chernin, Gil; Szwarcfiter, Iris; Scheinert, Dierk; Blessing, Erwin; Diehm, Nicolas; Dens, Jo; Walton, Antony; Verheye, Stefan; Shetty, Sharad; Jonas, Michael

    2018-06-16

    To report results of renal denervation (RDN) with the first catheter-based, non-balloon occlusion ultrasonic system in patients with resistant hypertension. In a multicenter, single-arm trial, 39 patients with resistant hypertension (defined as uncontrolled hypertension while taking ≥ 3 antihypertensive medications) were treated. The cohort consisted of 4 groups: severe resistant hypertension (office systolic blood pressure [OSBP] ≥ 160 mm Hg) treated with a unidirectional catheter (group 1; n = 14); severe resistant hypertension treated with a multidirectional catheter (group 2; n = 18); moderate resistant hypertension (OSBP 140-159 mm Hg) treated with a multidirectional catheter (group 3; n = 5); and recurrent severe resistant hypertension, after an initial response to RF RDN (group 4; n = 2). Blood pressure monitoring was performed for 6 months. Severe adverse events were not noted immediately after the procedure or during follow-up. Treatment time was longer with unidirectional than with multidirectional catheters (36.7 min ± 9.6 vs 11.9 min ± 5.8; P < .001). Mean reductions in office blood pressure (systolic/diastolic) at 1, 3, and 6 months were -26.1/-9.6 mm Hg, -28.0/-9.9 mm Hg, and -30.6/-14.1 mm Hg (P < .01 for all). Per-group analysis showed significant OSBP reduction for groups 1 and 2. Patients with isolated systolic hypertension had a significantly smaller reduction in OSBP after 6 months compared with patients with combined systolic/diastolic hypertension (-16.2 mm Hg ± 18.5 vs -9.9 mm Hg ± 33.4; P < .005). Use of the RDN system was feasible and safe in this phase I study. Significant blood pressure reductions were observed over 6 months, although less in patients with isolated systolic hypertension. Copyright © 2018 SIR. All rights reserved.

  8. Long-Duration Altitude-Controlled Balloons for Venus: A Feasibility Study Informed by Balloon Flights in Remote Environments on Earth

    NASA Astrophysics Data System (ADS)

    Voss, P. B.; Nott, J.; Cutts, J. A.; Hall, J. L.; Beauchamp, P. M.; Limaye, S. S.; Baines, K. H.; Hole, L. R.

    2013-12-01

    In situ exploration of the upper atmosphere of Venus, approximately 65-77 km altitude, could answer many important questions (Limaye 2013, Crisp 2013). This region contains a time-variable UV absorber of unknown composition that controls many aspects of the heat balance on Venus. Understanding the composition and dynamics of this unknown absorber is an important science goal; in situ optical and chemical measurements are needed. However, conventional approaches do not provide access to this altitude range, repeated traverses, and a mission lifetime of several months needed to effectively carry out the science. This paper examines concepts for altitude-controlled balloons not previously flown on planetary missions that could potentially provide the desired measurements. The concepts take advantage of the fact that at 60 km altitude, for example, the atmospheric density on Venus is about 40% of the sea-level density on earth and the temperature is a moderate 230 K. The solar flux is approximately double that on earth, creating some thermal challenges, but making photovoltaic power highly effective. Using a steady-state thermodynamic model and flight data from Earth, we evaluate the suitability of two types of altitude-controlled balloons for a potential mission on Venus. Such balloons could repeatedly measure profiles, avoid diurnal temperature extremes, and navigate using wind shear. The first balloon design uses air ballast (AB) whereby ambient air can be compressed into or released from a constant-volume balloon, causing it to descend or ascend accordingly. The second design uses lift-gas compression (LGC) to change the volume of a zero-pressure balloon, thereby changing its effective density and altitude. For an altitude range of 60-75 km on Venus, we find that the superpressure volume for a LGC balloon is about 5% of that needed for an AB balloon while the maximum pressurization is the same for both systems. The compressor work per km descent of the LGC balloon

  9. Cerebrospinal fluid enhancement on fluid attenuated inversion recovery images after carotid artery stenting with neuroprotective balloon occlusions: hemodynamic instability and blood-brain barrier disruption.

    PubMed

    Ogami, Ryo; Nakahara, Toshinori; Hamasaki, Osamu; Araki, Hayato; Kurisu, Kaoru

    2011-10-01

    A rare complication of carotid artery stenting (CAS), prolonged reversible neurological symptoms with delayed cerebrospinal fluid (CSF) space enhancement on fluid attenuated inversion recovery (FLAIR) images, is associated with blood-brain barrier (BBB) disruption. We prospectively identified patients who showed CSF space enhancement on FLAIR images. Nineteen patients-5 acute-phase and 14 scheduled-underwent 21 CAS procedures. Balloon catheters were navigated across stenoses, angioplasty was performed using a neuroprotective balloon, and stents were placed with after dilation under distal balloon protection. CSF space hyperintensity or obscuration on FLAIR after versus before CAS indicated CSF space enhancement. Correlations with clinical factors were examined. CSF space was enhanced on FLAIR in 12 (57.1%) cases. Postprocedural CSF space enhancement was significantly related to age, stenosis rate, acute-stage procedure, and total occlusion time. All acute-stage CAS patients showed delayed enhancement. Only age was associated with delayed CSF space enhancement in scheduled CAS patients. Ischemic intolerance for severe carotid artery stenosis and temporary neuroprotective balloon occlusion, causing reperfusion injury, seem to be the main factors that underlie BBB disruption with delayed CSF space enhancement shortly after CAS, rather than sudden poststenting hemodynamic change. Our results suggest that factors related to hemodynamic instability or ischemic intolerance seem to be associated with post-CAS BBB vulnerability. Patients at risk for hemodynamic instability or with ischemic intolerance, which decrease BBB integrity, require careful management to prevent intracranial hemorrhagic and other post-CAS complications.

  10. Embryo Transfer Catheters: Softer is Easier.

    PubMed

    Ruhlmann, Claudio; Gnocchi, Diego C; Cattaneo, Antonio R; Molina, Lucas G; Rivadeneira, Luciano Ruiz; Tessari, Lautaro; Martínez, Alejandro G

    2015-11-01

    This study aimed to compare the use of semi-rigid and flexible catheters in terms of pregnancy rate and level of difficulty of the embryo transfer (ET) procedure. Seven hundred and thirty-nine consecutive follicular aspirations for IVF or ICSI performed in our private fertility clinic within a 30-month period were randomly divided into two groups. Patients were allocated to either of the groups at the time of follicular retrieval with the aid of a random number generator according to the catheter used in ET: Group 1 (n = 370) - Frydman Classic Catheter 4.5 catheters; and Group 2 (n = 369) - Frydman Ultrasoft 4.5 catheters. Only patients offered ET in the randomized cycle were included (Group 1 = 363 and Group 2 = 340). Patients did not change groups after catheter allocation. Statistical analysis was carried out using an unpaired t-test or a chi square test as appropriate. Differences with P<0.05 were considered. A statistically significant difference in favor of the use of the Ultrasoft catheter was evident for parameters use of a tenaculum (19.8% vs. 5.9%) or a hysterometer (5.0% vs. 1.2%), presence of blood during post-ET inspection of the catheter (9.9% vs. 3.8%), and implantation rate (13.0% vs. 16.4%). Clinical pregnancy and delivery rates were comparable in both groups. Our results suggest that a softer catheter may help with difficult ETs. Softer catheters, as also reported by other authors, resulted in better implantation rates.

  11. Power supplies for long duration balloon flights

    NASA Astrophysics Data System (ADS)

    Lichfield, Ernest W.

    Long duration balloon flights require more electrical power than can be carried in primary batteries. This paper provides design information for selecting rechargeable batteries and charging systems. Solar panels for recharging batteries are discussed, with particular emphasis on cells mounting suitable for balloon flights and panel orientation for maximum power collection. Since efficient utilization of power is so important, modern DC to DC power conversion techniques are presented. On short flights of 1 day or less, system designers have not been greatly concerned with battery weight. But, with the advent of long duration balloon flights using superpressure balloons, anchor balloon systems, and RACOON balloon techniques, power supplies and their weight become of prime importance. The criteria for evaluating power systems for long duration balloon flights is performance per unit weight. Instrumented balloon systems have flown 44 days. For these very long duration flights, batteries recharged from solar cells are the only solution. For intermediate flight duration, say less than 10 days, the system designer should seriously consider using primary cells. The National Center for Atmospheric Research is sponsored by the National Science Foundation. Any opinions, findings and conclusions or recommendations expressed in this publication are those of the authors and do not necessarily reflect the views of the National Science Foundation.

  12. Gondola development for CNES stratospheric balloons

    NASA Astrophysics Data System (ADS)

    Vargas, A.; Audoubert, J.; Cau, M.; Evrard, J.; Verdier, N.

    The CNES has been supporting scientific ballooning since its establishment in 1962. The two main parts of the balloon system or aerostat are the balloon itself and the flight train, comprising the house-keeping gondola, for the control of balloon flight (localization and operational telemetry & telecommand - TM/TC), and the scientific gondola with its dedicated telecommunication system. For zero pressure balloon, the development of new TM/TC system for the housekeeping and science data transmission are going on from 1999. The main concepts are : - for balloon house-keeping and low rate scientific telemetry, the ELITE system, which is based on single I2C bus standardizing communication between the different components of the system : trajectography, balloon control, power supply, scientific TM/TC, .... In this concept, Radio Frequency links are developed between the house keeping gondola and the components of the aerostat (balloon valve, ballast machine, balloon gas temperature measurements, ...). The main objectives are to simplify the flight train preparation in term of gondola testing before flight, and also by reducing the number of long electrical cables integrated in the balloon and the flight train; - for high rate scientific telemetry, the use of functional interconnection Internet Protocol (IP) in interface with the Radio Frequency link. The main idea is to use off-the-shelf IP hardware products (routers, industrial PC, ...) and IP software (Telnet, FTP, Web-HTTP, ...) to reduce the development costs; - for safety increase, the adding, in the flight train, of a totally independent house keeping gondola based on the satellite Inmarsat M and Iridium telecommunication systems, which permits to get real time communications between the on-board data mobile and the ground station, reduced to a PC computer with modem connected to the phone network. These GEO and LEO telecommunication systems give also the capability to operate balloon flights over longer distance

  13. Urologic Outcomes of Children With Hemorrhagic Cystitis After Bone Marrow Transplant at a Single Institution.

    PubMed

    Au, Jason K; Graziano, Christopher; Elizondo, Rodolfo A; Ryan, Sheila; Roth, David R; Koh, Chester J; Gonzales, Edmond T; Tu, Duong T; Janzen, Nicolette; Naik, Swati; Seth, Abhishek

    2017-03-01

    To analyze clinical outcomes and the risk factors associated with genitourinary (GU) morbidity and mortality in children who present with hemorrhagic cystitis (HC) after bone marrow transplant (BMT). A retrospective chart review of patients with HC who had undergone BMT at a single pediatric hospital from 2008 to 2015 was conducted. Demographic data, severity of hematuria, HC management, and mortality were analyzed. Bivariate analysis and binary logistic regression were performed to identify risk factors. Out of 43 patients who met inclusion criteria, 67.4% were male with a median age at BMT of 10.2 years (interquartile range 5.8-14.6). Percutaneous nephrostomy catheters were inserted in 5 patients for urinary diversion. All-cause mortality was 32.6% (N = 14). Intravesical retroviral therapy (P <.001), HC grade (P <.001), total Foley time (P <.001), total gross hematuria time (P <.001), total days hospitalized (P = .012), and days to most improved hematuria (P = .032) were associated with significant GU morbidity on bivariate analysis. On multivariable analysis, days to most improved hematuria was associated with significant GU morbidity odds ratio of 1.177 (1.006-1.376) (P = .042). Status of percutaneous nephrostomy was not associated with increased mortality (P = .472); however, in the multivariate model, BK viremia (P = .023), need for renal dialysis (P = .003), and presence of Foley catheter (P = .005) were associated with increased mortality. Children with HC after BMT fall in a very high-risk category with high mortality and significant GU morbidity. The presence of a Foley catheter, need for dialysis, and BK viremia are associated with increased mortality. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. A prospective, multi-center study of the chocolate balloon in femoropopliteal peripheral artery disease: The Chocolate BAR registry.

    PubMed

    Mustapha, Jihad A; Lansky, Alexandra; Shishehbor, Mehdi; Miles McClure, John; Johnson, Sarah; Davis, Thomas; Makam, Prakash; Crowder, William; Konstantino, Eitan; Attaran, Robert R

    2018-05-01

    The Chocolate BAR study is a prospective multicenter post-market registry designed to evaluate the safety and performance of the Chocolate percutaneous transluminal angioplasty balloon catheter in a broad population with symptomatic peripheral arterial disease. The primary endpoint is acute procedural success (defined as ≤30% residual stenosis without flow-limiting dissection); secondary long-term outcomes include freedom from target lesion revascularization (TLR), major unplanned amputation, survival, and patency. A total of 262 patients (290 femoropopliteal lesions) were enrolled at 30 US centers between 2012 and 2014. The primary endpoint of procedure success was achieved in 85.1% of cases, and freedom from stenting occurred in 93.1%. Bail out stenting by independent adjudication occurred in 1.6% of cases and there were no flow limiting dissections. There was mean improvement of 2.1 Rutherford classes (±1.5) at 12-months, with 78.5% freedom from TLR, 97.2% freedom from major amputation, and 93.3% freedom from all-cause mortality. Core Lab adjudicated patency was 64.1% at 12 months. Use of the Chocolate balloon in an "all-comers" population achieved excellent procedural outcomes with low dissection rates and bailout stent use. © 2018 Wiley Periodicals, Inc.

  15. Catheter-related bloodstream infection with removal of catheter in pediatric oncology patients: a 10-year experience in Taiwan.

    PubMed

    Chen, Shih-Hsiang; Yang, Chao-Ping; Jaing, Tang-Her; Lai, Jin-Yao; Hung, Iou-Jih

    2012-04-01

    Long-term central venous catheter (CVC) implantation has become more affordable in Taiwan since 1995. Surgical removal of the catheter may be the essential treatment for catheter-related bloodstream infections (CRBSI). The aim of this study was to evaluate the clinical features and microbial isolates in pediatric cancer patients with removal of CVC for CRBSI. The records of positive blood culture from hospitalized pediatric oncology patients between 1995 and 2004 were reviewed. One hundred and forty-three patients implanted with a long-term CVC were further identified. Seventeen catheters in 16 patients developed catheter-related bacteremia that needed catheter removal. The rate of catheter removal was 11.9%. The median device life was 7.7 months. Six catheters were removed within 3 months of insertion. Nine of the 17 catheters were removed from patient younger than 2 years. Eight infections occurred during severe neutropenia, and 6 patients had refractory or relapsed underlying disease. The cultural isolates were Gram-negative bacilli in 7, Gram-positive in 5, fungi in 5, and atypical mycobacterium in 1. The frequency of catheter removal for infection control was significantly higher in the first 5 years (1994-1999) compared to the last 5 years (2000-2004) (30.9 vs. 4.0%, p = 2.3 × 10(-4)). Factors such as microbiological isolates, age of infection, the status of malignancy, and neutropenia are related to catheter outcome. The reduction in patients with positive cultures needing removal of the catheters can be related to improved nursing care and more aggressive antibiotic therapy.

  16. Are drug-coated balloons cost effective for femoropopliteal occlusive disease? A comparison of bare metal stents and uncoated balloons.

    PubMed

    Poder, Thomas G; Fisette, Jean-François

    2016-07-01

    To perform a cost-effectiveness analysis to help hospital decision-makers with regard to the use of drug-coated balloons compared with bare metal stents and uncoated balloons for femoropopliteal occlusive disease. Clinical outcomes were extracted from the results of meta-analyses already published, and cost units are those used in the Quebec healthcare network. The literature review was limited to the last four years to obtain the most recent data. The cost-effectiveness analysis was based on a 2-year perspective, and risk factors of reintervention were considered. The cost-effectiveness analysis indicated that drug-coated balloons were generally more efficient than bare metal stents, particularly for patients with higher risk of reintervention (up to CAD$1686 per patient TASC II C or D). Compared with uncoated balloons, results indicated that drug-coated balloons were more efficient if the reintervention rate associated with uncoated balloons is very high and for patients with higher risk of reintervention (up to CAD$3301 per patient). The higher a patient's risk of reintervention, the higher the savings associated with the use of a drug-coated balloon will be. For patients at lower risk, the uncoated balloon strategy is still recommended as a first choice for endovascular intervention.

  17. Catheter ablation of atrial fibrillation using remote magnetic catheter navigation: a case-control study.

    PubMed

    Arya, Arash; Zaker-Shahrak, Ruzbeh; Sommer, Phillip; Bollmann, Andreas; Wetzel, Ulrike; Gaspar, Thomas; Richter, Sergio; Husser, Daniela; Piorkowski, Christopher; Hindricks, Gerhard

    2011-01-01

    To compare the acute and the 6 month outcome of catheter ablation of atrial fibrillation (AF) using irrigated tip magnetic catheter and remote magnetic cathter navigation (RMN) with manual catheter navigation (MCN) in patients with paroxysmal and persistent AF. In this retrospective analysis 356 patients (235 male, mean age: 57.9 ± 10.9 years) with AF (70.5%, paroxysmal) who underwent catheter ablation between August 2007 and May 2008 using either RMN (n = 70, 46 male, mean age: 57.9 ± 10.1 years, 50% paroxysmal) or MCN (n = 286, 189 male, mean age: 58.0 ± 13.9 years, 75.5% paroxysmal) were included. All patients completed an intensive follow-up strategy. Complete pulmonary vein isolation was achieved in 87.6 and 99.6% of patients in RMN and MCN groups, respectively (P < 0.05). The procedure, fluoroscopy, and radiofrequency application times were 223 ± 44 vs. 166 ± 52 min (P < 0.0001), 13.7 ± 7.8 vs. 34.5 ± 15.1 min (P < 0.0001), and 75.4 ± 20.9 vs. 53.2 ± 21.4 min (P < 0.0001) in RMN and MCN groups, respectively. Seven (10.0%) and 28 (9.8%) patients in RMN and MCN groups received antiarrhythmic medications during the follow-up (P = 0.96). All the patients completed the 6 month follow-up. Freedom from AF at 6 months was achieved in 57.8 and 66.4% of the patients in RMN and MCN groups, respectively (P = 0.196). In patients without previous AF catheter ablation procedure the freedom from AF at 6 months were 68.2 and 60.5% in the MCN and RMN groups, respectively (P = 0.36). Catheter ablation using irrigated tip magnetic catheter and RMN is an effective and safe method for catheter ablation of AF. Compared to manual catheter navigation, the procedure and radiofrequency application times were longer and fluoroscopy time was shorter in the RMN group compared with the MCN group.

  18. Mitral balloon valvuloplasty during pregnancy:The long term up to 17 years obstetric outcome and childhood development

    PubMed Central

    A, Gulraze; W, Kurdi; FA, Niaz; ME, Fawzy

    2014-01-01

    Background & Objectives : We report 17 years outcome of subsequent pregnancies of women with severe Mitral Stenosis (MS) who underwent Mitral Balloon Valvuloplasty (MBV) during pregnancy and the follow up of the children born of such pregnancies. Methods: Twenty three pregnant patients suffering from severe MS (NYHA-New York Heart Association class III/IV) who underwent MBV by Inoue balloon catheter technique during second trimester were enrolled. The study was performed between January 1992 and December 2008 at King Faisal Specialist Hospital & Research Centre, Riyadh, Saudi Arabia, during which time, details about the obstetric outcome and childhood development were recorded. Mean follow up period was 10± 5.5 years (range 1-17 years). Results: MBV was successful in all patients with improvement in their NYHA class to I/II. All patients were followed until term and had uneventful course after MBV. Twenty two (95.6%) patients delivered 23 babies including a twin birth. These children exhibited normal growth and development according to their age. Nineteen patients had further pregnancies and gave birth to 38 live & healthy babies with one still birth and no unfavorable maternal outcome. Of these, 97.4% were singleton pregnancies while 2.6% were twin pregnancies. Spontaneous abortions were recorded in 21.5% and there was one still birth (2.5%) and one ectopic pregnancy (2.5%). Conclusion : Mitral Balloon Valvuloplasty is a safe and useful procedure during pregnancy, with no short or long term adverse affects on the mothers and their obstetric future. The children born of subsequent pregnancies exhibited normal physical and mental development. PMID:24639837

  19. Is it feasible to diagnose catheter-related candidemia without catheter withdrawal?

    PubMed

    Fernández-Cruz, Ana; Martín-Rabadán, Pablo; Suárez-Salas, Marisol; Rojas-Wettig, Loreto; Pérez, María Jesús; Guinea, Jesús; Guembe, María; Peláez, Teresa; Sánchez-Carrillo, Carlos; Bouza, Emilio

    2014-07-01

    Many bloodstream infections (BSI) in patients with central venous catheters (CVC) are not catheter-related (CR). Assessment of catheter involvement without catheter withdrawal has not been studied in candidemia. We assessed the value of conservative techniques to evaluate catheters as the origin of candidemia in patients with CVC in a prospective cohort study (superficial Gram stain and culture, Kite technique (Gram stain and culture of the first 1 cm blood drawn from the CVC), proportion of positive blood cultures (PPBCs), differential time to positivity (DTP), and minimal time to positivity (MTP)). All catheters were cultured at withdrawal. From June 2008 to January 2012, 22 cases fulfilled the inclusion criteria. CR-candidemia (CRC) was confirmed in 10. Validity values for predicting CRC were: superficial Gram stain (S, 30%; Sp, 81.83%; PPV, 60%; NPV, 56.3%; Ac, 57.1%), superficial cultures (S, 40%; Sp, 75%; PPV, 57.1%; NPV, 60%; Ac, 59.1%), Kite Gram stain (S, 33.3%; Sp, 66.7%; PPV, 50%; NPV, 50%; Ac, 50%), Kite culture (S, 80%; Sp, 66.7%; PPV, 66.7%; NPV, 80%; Ac, 72.7%), PPBC (S, 50%; Sp, 41.7%; PPV, 41.7%; NPV, 50.0%; Ac, 45.5%), DTP (S, 100%; Sp, 33.3%; PPV, 55.6%; NPV, 100%; Ac, 63.6%), and MTTP (S, 70%; Sp, 58.3%; PPV, 58.3%; NPV, 70%; Ac, 63.6%). While combinations of two tests improved sensitivity and NPV, more than two tests did not improve validity values. Classic tests to assess CR-BSI caused by bacteria cannot be reliably used to diagnose CRC. Combinations of tests could be useful, but more and larger studies are required. © The Author 2014. Published by Oxford University Press on behalf of The International Society for Human and Animal Mycology. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  20. Balloon Ascent: 3-D Simulation Tool for the Ascent and Float of High-Altitude Balloons

    NASA Technical Reports Server (NTRS)

    Farley, Rodger E.

    2005-01-01

    The BalloonAscent balloon flight simulation code represents a from-scratch development using Visual Basic 5 as the software platform. The simulation code is a transient analysis of balloon flight, predicting the skin and gas temperatures along with the 3-D position and velocity in a time and spatially varying environment. There are manual and automated controls for gas valving and the dropping of ballast. Also, there are many handy calculators, such as appropriate free lift, and steady-state thermal solutions with temperature gradients. The strength of this simulation model over others in the past is that the infrared environment is deterministic rather than guessed at. The ground temperature is specified along with the emissivity, which creates a ground level IR environment that is then partially absorbed as it travels upward through the atmosphere to the altitude of the balloon.

  1. Lessons from individualized cryoballoon sizing. Is there a role for the small balloon?

    PubMed

    Hartl, Stefan; Dorwarth, Uwe; Bunz, Benedikt; Wankerl, Michael; Ebersberger, Ullrich; Hoffmann, Ellen; Straube, Florian

    2017-10-01

    Cryoablation for paroxysmal atrial fibrillation (PAF) is well established. The single-big-balloon strategy has been preferred for pulmonary vein isolation (PVI) using the second generation cryoballoon (CBG2). Individual PV-morphologies raise the question if an individualized anatomic approach using the 23-mm or 28-mm CB is reasonable. Consecutive patients were prospectively enrolled in the non-randomized single-center study. Patients were treated with the 28-mm CB, if any PV was >21mm, the 23-mm CB, if all PV were ≤21mm, or both sizes, if PVI was difficult. The primary endpoint was arrhythmia-free survival. The secondary endpoint considered procedural results and complications. Overall, 197 patients with symptomatic PAF (64±11 years, 36% female) were included. Acute PVI was achieved in 99.9% of PV. Based on preprocedural imaging, the 28-mm CB was applied as the primary catheter in 47% (92/197 patients), the 23-mm CB in 53% (105/197, p=0.23). The 23-mm CB group included more females, patients with short left atrial (LA)-diameters (each p<0.01), and smaller patients (p=0.04). Both CB-sizes were used in 24% (47/197). Additional 23-mm CB usage was necessary in 23% (21/92) of patients, mainly because of insufficient PV-occlusion with the 28-mm CB. Additional 28-mm CB usage was necessary in 25% (26/105, p=0.82), mainly because PV diameters were larger than initially measured. Both CB-sizes were equally safe and effective with a low complication rate and an overall success rate of 86% at 12 and 71% at 18 months (6% on antiarrhythmic drugs). No predictors for AF-recurrence were identified. CB ablation can sometimes be challenging. The 28-mm CB is the preferred catheter in all patients. If balloon positioning is difficult, the 23-mm CB is an option to achieve PVI in small veins. Further studies need to investigate if the 23-mm CB could be beneficial as the primary CB in females with small body height and short LA diameter. Copyright © 2017 Japanese College of Cardiology

  2. Evaluation of urinary catheters coated with sustained-release varnish of chlorhexidine in mitigating biofilm formation on urinary catheters in dogs.

    PubMed

    Segev, G; Bankirer, T; Steinberg, D; Duvdevani, M; Shapur, N K; Friedman, M; Lavy, E

    2013-01-01

    Biofilm formation occurs commonly on urinary catheters. To assess the efficacy of urinary catheters coated with sustained-release varnish of chlorhexidine in decreasing catheter-associated biofilm formation in dogs. Thirty client-owned dogs. Prospective study. Thirteen dogs were catheterized with urinary catheters coated with sustained-release varnish of chlorhexidine (study group), and 13 dogs were catheterized with an untreated urinary catheter (control group). Presence and intensity of biofilm formation on the urinary catheters were assessed and compared between the groups by evaluating colony-forming units (CFU) of biofilm bacteria, and semiquantitatively, using confocal laser scanning microscopy and electron microscopy. None of the dogs experienced adverse effects associated with the presence of the urinary catheters. Median CFU count of biofilm bacteria at all portions of the urinary catheter was significantly (P < .001) lower in the study compared with the control group. The degree of biofilm formation on the urinary catheters, as evaluated by confocal laser scanning microscopy and electron microscopy, was significantly lower in the study compared with the control group. Electron microscopy examination identified crystals on some of the urinary catheters. The proportion of catheters on which crystals were observed was significantly lower on the distal part of the urinary catheter in the study group compared with the control group (16.7% versus 66.7%, respectively; P = .04). Chlorhexidine sustained-release varnish-coated urinary catheters effectively decrease urinary catheter-associated biofilm formation in dogs. Copyright © 2012 by the American College of Veterinary Internal Medicine.

  3. Toxicity testing of urinary catheters.

    PubMed

    Talja, M; Andersson, L C; Ruutu, M; Alfthan, O

    1985-10-01

    The tissue toxicity of 23 urinary catheter batches (6 latex and 2 non-latex brands) was tested in vitro and in vivo. In vitro, a human T-cell leukemia line (JM) was cultured in the presence of different concentrations of eluates made from the catheters. The cytotoxicity of the eluates was assessed from their ability to inhibit DNA synthesis measured by incorporation of 3H-thymidine. In vivo, two methods were used. Strips of catheters were implanted into the rabbit dorsal muscle and pieces of catheters were implanted into the rat peritoneal cavity. After four days, the foreign body reaction, type of inflammation and necrosis were quantified macroscopically and by light microscopy. The results of the in vitro cytotoxicity test were correlated with those of in vivo methods. The rat peritoneal implantation test correlated better with the cell culture test (P less than 0.01) than with the rabbit muscle implantation test (P less than 0.05). Based on the clinical experience of urethral stricture complications caused by urinary catheters, catheters yielding eluate which at 30% dilution inhibited 50% DNA synthesis were regarded as toxic. According to this, the rabbit muscle implantation test was not reliable in testing the tissue toxicity of urinary catheters, while the cell culture test was quantitative and seemed to correlate with both the rat peritoneal implantation test and with the clinical complications observed.

  4. Meeting the Challenge to Balloon Science

    NASA Astrophysics Data System (ADS)

    Jones, W. Vernon

    The promise of superpressure ballooning is helping the balloon program evolve toward a cost-effective means for frequent access to near-space. Superpressure balloons fabricated from strong, light-weight composite materials have the potential for increasing flight times of ton-class payloads to 100 days or more at altitudes above 5 mbars at essentially any geographic latitude. Although this new capability is still in an embryonic stage, its potential has already had an impact. Specifically, a new NASA Office of Space Science policy for University-class Explorer missions allows balloon investigations to compete on an equal basis with other low-cost missions requiring expendable launch vehicles. The new challenge for the science community is to design winning payloads that can be built within the cost cap of $13 M, including launch costs, and be developed within two to three years from selection to launch. Defining the international trajectories and getting the overflight agreements for balloon flights that make several circumnavigations of Earth will also be a challenge

  5. The French balloon and sounding rocket space program

    NASA Astrophysics Data System (ADS)

    Coutin/Faye, S.; Sadourny, I.

    1987-08-01

    Stratospheric and long duration flight balloon programs are outlined. Open stratospheric balloons up to 1 million cu m volume are used to carry astronomy, solar system, aeronomy, stratosphere, biology, space physics, and geophysics experiments. The long duration balloons can carry 50 kg payloads at 20 to 30 km altitude for 10 days to several weeks. Pressurized stratospheric balloons, and infrared hot air balloons are used. They are used to study the dynamics of stratospheric waves and atmospheric water vapor. Laboratories participating in sounding rocket programs are listed.

  6. TMBM: Tethered Micro-Balloons on Mars

    NASA Technical Reports Server (NTRS)

    Sims, M. H.; Greeley, R.; Cutts, J. A.; Yavrouian, A. H.; Murbach, M.

    2000-01-01

    The use of balloons/aerobots on Mars has been under consideration for many years. Concepts include deployment during entry into the atmosphere from a carrier spacecraft, deployment from a lander, use of super-pressurized systems for long duration flights, 'hot-air' systems, etc. Principal advantages include the ability to obtain high-resolution data of the surface because balloons provide a low-altitude platform which moves relatively slowly. Work conducted within the last few years has removed many of the technical difficulties encountered in deployment and operation of balloons/aerobots on Mars. The concept proposed here (a tethered balloon released from a lander) uses a relatively simple approach which would enable aspects of Martian balloons to be tested while providing useful and potentially unique science results. Tethered Micro-Balloons on Mars (TMBM) would be carried to Mars on board a future lander as a stand-alone experiment having a total mass of one to two kilograms. It would consist of a helium balloon of up to 50 cubic meters that is inflated after landing and initially tethered to the lander. Its primary instrumentation would be a camera that would be carried to an altitude of up to tens of meters above the surface. Imaging data would be transmitted to the lander for inclusion in the mission data stream. The tether would be released in stages allowing different resolutions and coverage. In addition during this staged release a lander camera system may observe the motion of the balloon at various heights above he lander. Under some scenarios upon completion of the primary phase of TMBM operations, the tether would be cut, allowing TMBM to drift away from the landing site, during which images would be taken along the ground.

  7. Advances in Scientific Balloon Thermal Modeling

    NASA Technical Reports Server (NTRS)

    Bohaboj, T.; Cathey, H. M., Jr.

    2004-01-01

    The National Aeronautics and Space Administration's Balloon Program office has long acknowledged that the accurate modeling of balloon performance and flight prediction is dependant on how well the balloon is thermally modeled. This ongoing effort is focused on developing accurate balloon thermal models that can be used to quickly predict balloon temperatures and balloon performance. The ability to model parametric changes is also a driver for this effort. This paper will present the most recent advances made in this area. This research effort continues to utilize the "Thrmal Desktop" addition to AUTO CAD for the modeling. Recent advances have been made by using this analytical tool. A number of analyses have been completed to test the applicability of this tool to the problem with very positive results. Progressively detailed models have been developed to explore the capabilities of the tool as well as to provide guidance in model formulation. A number of parametric studies have been completed. These studies have varied the shape of the structure, material properties, environmental inputs, and model geometry. These studies have concentrated on spherical "proxy models" for the initial development stages and then to transition to the natural shaped zero pressure and super pressure balloons. An assessment of required model resolution has also been determined. Model solutions have been cross checked with known solutions via hand calculations. The comparison of these cases will also be presented. One goal is to develop analysis guidelines and an approach for modeling balloons for both simple first order estimates and detailed full models. This papa presents the step by step advances made as part of this effort, capabilities, limitations, and the lessons learned. Also presented are the plans for further thermal modeling work.

  8. Thermal performance modeling of NASA s scientific balloons

    NASA Astrophysics Data System (ADS)

    Franco, H.; Cathey, H.

    The flight performance of a scientific balloon is highly dependant on the interaction between the balloon and its environment. The balloon is a thermal vehicle. Modeling a scientific balloon's thermal performance has proven to be a difficult analytical task. Most previous thermal models have attempted these analyses by using either a bulk thermal model approach, or by simplified representations of the balloon. These approaches to date have provided reasonable, but not very accurate results. Improvements have been made in recent years using thermal analysis tools developed for the thermal modeling of spacecraft and other sophisticated heat transfer problems. These tools, which now allow for accurate modeling of highly transmissive materials, have been applied to the thermal analysis of NASA's scientific balloons. A research effort has been started that utilizes the "Thermal Desktop" addition to AUTO CAD. This paper will discuss the development of thermal models for both conventional and Ultra Long Duration super-pressure balloons. This research effort has focused on incremental analysis stages of development to assess the accuracy of the tool and the required model resolution to produce usable data. The first stage balloon thermal analyses started with simple spherical balloon models with a limited number of nodes, and expanded the number of nodes to determine required model resolution. These models were then modified to include additional details such as load tapes. The second stage analyses looked at natural shaped Zero Pressure balloons. Load tapes were then added to these shapes, again with the goal of determining the required modeling accuracy by varying the number of gores. The third stage, following the same steps as the Zero Pressure balloon efforts, was directed at modeling super-pressure pumpkin shaped balloons. The results were then used to develop analysis guidelines and an approach for modeling balloons for both simple first order estimates and detailed

  9. Development of a super-pressure balloon with a diamond-shaped net --- result of a ground inflation test of a 2,000 cubic-meter balloon ---

    NASA Astrophysics Data System (ADS)

    Saito, Yoshitaka; Nakashino, Kyoichi; Akita, Daisuke; Matsushima, Kiyoho; Shimadu, Shigeyuki; Goto, Ken; Hashimoto, Hiroyuki; Matsuo, Takuma

    2016-07-01

    A light super-pressure balloon has been developed using a method to cover a balloon with a diamond-shaped net of high-tensile fibers. The goal is to fly a payload of 900 kg to the altitude of 37 km with a 300,000 m^{3} balloon. Beginning from a demonstration test of the net-balloon with a 10 m^{3} balloon in 2010, we have been polished the net-balloon through ground inflation tests and flight tests, including a flight test of a 3,000 m ^{3} balloon in the tandem balloon configuration with a 15,000 m^{3} zero-pressure balloon in 2012, and a flight test of a 10 m^{3} balloon in the tandem balloon configuration with a 2 kg rubber balloon in 2013, as reported in the last COSPAR. In 2014, we developed a 5,000 m^{3} balloon and performed a ground inflation test to find that the balloon burst from a lip panel for termination with a differential pressure of 425 Pa. It was due to a stress concentration at the edge of a thick tape attached along the termination mechanism. In 2015, we modified the balloon by adding tapes on the lip panel to avoid the stress concentration, and also shorten the net length to leave some margin of the film and performed a ground inflation test again to find the balloon showed asymmetrical deployment and burst from the edge of the net with a differential pressure of 348 Pa. We consider it is due to the margin of the film along the circumferential direction, and proposed a gore shape which circumference length is kept as determined by the pumpkin shape of the balloon but setting meridian length longer than that. We developed a 10 m^{3} balloon with the gore design to find that the balloon deployed symmetrically and showed the burst pressure of 10,000 Pa. In 2016, we are going to develop a 2,000 m^{3} balloon with the gore design and perform its ground inflation test. In this paper, we are going to report its result with the sequence of the development.

  10. A Methane Balloon Inflation Chamber

    ERIC Educational Resources Information Center

    Czerwinski, Curtis J.; Cordes, Tanya J.; Franek, Joe

    2005-01-01

    The various equipments, procedure and hazards in constructing the device for inflating a methane balloon using a standard methane outlet in a laboratory are described. This device is fast, safe, inexpensive, and easy to use as compared to a hydrogen gas cylinder for inflating balloons.

  11. Catheter-associated urinary tract infection.

    PubMed

    Tambyah, Paul A; Oon, Jolene

    2012-08-01

    Catheter-associated urinary tract infection (CAUTI) is the commonest nosocomial infection worldwide. Here we review the recent advances in the prevention of CAUTI. After more than 30 years, new guidelines were issued in 2008-2011 by the Infectious Diseases Society of America, Society for Healthcare Epidemiology of America, Healthcare Infection Control Practices Advisory Committee and European Association of Urology. These guidelines addressed novel technologies such as silver alloy or antimicrobial coatings on catheters, hydrophilic catheters, urethral stents, use of sealed catheter-tube junctions and antiinfective bladder irrigation. In addition, multiple trials have been published recently on the reduction of inappropriate urinary tract catheterization. Numerous strategies have been developed to reduce the incidence of CAUTI but few have proven effective. Reducing the inappropriate use of catheters and development of novel technologies targeted against these increasingly multidrug-resistant pathogens may be useful in the prevention of CAUTI in our vulnerable patients.

  12. Insertion of tunneled hemodialysis catheters without fluoroscopy.

    PubMed

    Motta Elias, Rosilene; da Silva Makida, Sonia Cristina; Abensur, Hugo; Martins Castro, Manuel Carlos; Affonso Moysés, Rosa Maria; Pereira, Benedito Jorge; Bueno de Oliveira, Rodrigo; Luders, Cláudio; Romão, João Egidio

    2010-01-01

    The tunneled cuffed catheter (TCC) is used as a bridge access for hemodialysis. Few prospective studies have been designed to evaluate conversion from non-tunneled to TCC without the use of fluoroscopy when performed by nephrologists. We performed an observational prospective cohort in incident patients receiving hemodialysis through a non-tunneled right jugular vein catheter. 130 procedures were performed in 122 patients (51+/-18 years). The success rate was 100%. There was a total of 26,546 catheter days. Ninety-one of the 130 catheters were removed during the study period. Life table analysis revealed primary patency rates of 92%, 82%, and 68% at 30, 60, and 120 days, respectively. Infection requiring catheter removal occurred at a frequency of 0.09 per 100 catheter days. Catheter malfunction requiring intervention occurred at a rate of 0.03 per 100 catheter days. Hypertension and duration of existing non-tunneled catheter of less than 2 weeks were independently associated with better TCC survival. The conversion from non-tunneled to TCC performed by nephrologists and without fluoroscopy may be safe by using the internal right jugular vein. The ideal time to do this procedure is within less than 2 weeks of existing non-tunneled catheter.

  13. Balloon pulmonary valvotomy--not just a simple balloon dilatation.

    PubMed

    Mohanty, Subhendu; Pandit, Bhagya Narayan; Tyagi, Sanjay

    2014-01-01

    Balloon pulmonary valvotomy is the preferred mode of treatment in patients with isolated pulmonary valvar stenosis and has shown good long term results. It is generally considered a safe procedure with few complications. There have been however, case reports of potentially fatal acute severe pulmonary edema occurring after the procedure in some patients. The cause of this complication and its pathophysiology is still not clear. Its occurrence is also infrequent with less than 5 cases reported till now. We report a case of pulmonary valvar stenosis which developed acute severe refractory pulmonary edema immediately after balloon pulmonary valvotomy. Copyright © 2014 Cardiological Society of India. Published by Elsevier B.V. All rights reserved.

  14. A Retrograde Transvenous Embolization Technique with Balloon-Assisted Arterial Aspiration for a Peripheral Arteriovenous Malformation with a Venous Pouch

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kuhara, Asako, E-mail: kuhara-asako@med.kurume-u.ac.jp; Tanaka, Norimitsu; Koganemaru, Masamichi

    Management of arteriovenous malformations (AVMs) is challenging, and there is no consensus regarding either the ideal approach or the treatment timing. Percutaneous embolization is the most frequent approach currently used and is considered the first-line technique for AVMs. There is an ongoing discussion about the best technical approach to embolize AVMs. AVMs associated with a dominant outflow vein (DOV) are rare. Embolization of both the DOV and the nidus is considered more effective. Herein, we report a novel technique of transvenous embolization of a DOV under negative pressure from an arterial balloon catheter in a case of a peripheral AVM.more » This technique allows the embolization of the DOV and the nidus retrogradely.« less

  15. Sinuplasty (Balloon Catheter Dilation)

    MedlinePlus

    ... be done without actual tissue removal. Although this technology initially was met with criticism, clinical studies have demonstrated that it is a safe tool in the management of chronic sinusitis. The American Rhinologic Society as well as the American Academy of Otolaryngology- ...

  16. 14 CFR 61.115 - Balloon rating: Limitations.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... takes a practical test in a balloon with an airborne heater: (1) The pilot certificate will contain a limitation restricting the exercise of the privileges of that certificate to a balloon with an airborne... removed when the person obtains the required aeronautical experience in a balloon with an airborne heater...

  17. Gradient magnetometer system balloons

    NASA Astrophysics Data System (ADS)

    Korepanov, Valery; Tsvetkov, Yury

    2005-08-01

    Earth's magnetic field study still remains one of the leading edges of experimental geophysics. Thus study is executed on the Earth surface, including ocean bottom, and on satellite heights using component, mostly flux-gate magnetometers. But balloon experiments with component magnetometers are very seldom, first of all because of great complexity of data interpretation. This niche still waits for new experimental ideology, which will allow to get the measurements results with high accuracy, especially in gradient mode. The great importance of precise balloon-borne component magnetic field gradient study is obvious. Its technical realization is based both on the available at the marked high-precision non-magnetic tiltmeters and on recent achievements of flux-gate magnetometry. The scientific goals of balloon-borne magnetic gradiometric experiment are discussed and its practical realization is proposed.

  18. High intensity focused ultrasound (HIFU) treatment of BPH: results of a multi-center phase III study

    NASA Astrophysics Data System (ADS)

    Sanghvi, N.; Gardner, T.; Koch, M.; Bihrle, R.; Foster, R.; Resnick, M.; Seftel, A.; Grunberger, I.; Stiedle, C.; Corchan, J.

    2003-04-01

    The five centers phase III trial was to show that HIFU can treat prostate tissue thermally for symptomatic relief of BPH and improve flow rates. At five sites, 68 BPH patients were treated with the Sonablate device (Focus Surgery, Inc. Indianapolis, IN). A urethral Foley catheter was inserted into the urethra to aid in positioning and was kept in-situ during the treatment. A cooling device was used to cool the rectal wall. The patients returned home within a few hours after the procedure. The Foley catheter was kept electively to avoid any incidence of acute urinary retention following the therapy. The catheter was removed after 4-5 days. The average treatment time was 38 minutes. The patients were treated without pain, blood loss or complications. At 90 days post treatment, average Qmax and AUA Symptom Scores improved from 8.7 ml/s to 12.66 ml/s (48%) and 23.06 to 11.62 (52%), respectively. Significant prostate tissue changes took place before and after the treatment. 80% of the patients had cavity formation at the site of treatment at the bladder neck and prostate. Nonsurgical HIFU therapy is safe and effective for providing symptomatic relief of BPH symptoms and the treatment can be performed as an outpatient procedure.

  19. NASA Langley Research Center tethered balloon systems

    NASA Technical Reports Server (NTRS)

    Owens, Thomas L.; Storey, Richard W.; Youngbluth, Otto

    1987-01-01

    The NASA Langley Research Center tethered balloon system operations are covered in this report for the period of 1979 through 1983. Meteorological data, ozone concentrations, and other data were obtained from in situ measurements. The large tethered balloon had a lifting capability of 30 kilograms to 2500 meters. The report includes descriptions of the various components of the balloon systems such as the balloons, the sensors, the electronics, and the hardware. Several photographs of the system are included as well as a list of projects including the types of data gathered.

  20. Bacterial contamination of epidural catheters: microbiological examination of 502 epidural catheters used for postoperative analgesia.

    PubMed

    Steffen, Peter; Seeling, Wulf; Essig, Andreas; Stiepan, Erika; Rockemann, Michael Georg

    2004-03-01

    To investigate the frequency of bacterial colonization of epidural catheters used for postoperative pain treatment longer than 24 hours in abdominal, thoracic, or trauma surgery patients. Retrospective study. Intermediate care facility and general ward of a university hospital. 502 patients who received epidural catheters after abdominal, thoracic, or vascular surgery at our institution from January 1996 to December 2000. Placement of an epidural catheter, which was used for postoperative pain treatment, for more than 24 hours. The puncture site dressing included saturation each day with povidone-iodine. Microbiologic monitoring of epidural catheter tips and daily examination of puncture sites with regard to signs of inflammation took place. Four times daily patients were examined to check adequacy of pain treatment and neurologic deficits. Catheter tip cultures were positive in 29 patients (5.8%). Staphylococcus epidermidis was isolated in 22 cases (76%). No case of spinal epidural abscess was observed within 6 months after epidural catheterization. The average catheterization time was 5 days (quartile range: 4 to 6 days). Meticulous management ensures a relatively low level of bacterial contamination in epidural catheters applied for postoperative pain treatment greater than 5 days. Contamination rarely leads to spinal epidural infection.

  1. Heat Transfer Model for Hot Air Balloons

    NASA Astrophysics Data System (ADS)

    Llado-Gambin, Adriana

    A heat transfer model and analysis for hot air balloons is presented in this work, backed with a flow simulation using SolidWorks. The objective is to understand the major heat losses in the balloon and to identify the parameters that affect most its flight performance. Results show that more than 70% of the heat losses are due to the emitted radiation from the balloon envelope and that convection losses represent around 20% of the total. A simulated heating source is also included in the modeling based on typical thermal input from a balloon propane burner. The burner duty cycle to keep a constant altitude can vary from 10% to 28% depending on the atmospheric conditions, and the ambient temperature is the parameter that most affects the total thermal input needed. The simulation and analysis also predict that the gas temperature inside the balloon decreases at a rate of -0.25 K/s when there is no burner activity, and it increases at a rate of +1 K/s when the balloon pilot operates the burner. The results were compared to actual flight data and they show very good agreement indicating that the major physical processes responsible for balloon performance aloft are accurately captured in the simulation.

  2. Balloon Borne Ultraviolet Spectrometer.

    DTIC Science & Technology

    1978-12-28

    n.c.aaary ond lden lfy by block numb.r) ultraviolet ground support equipment (GSE) spectrometers flight electronics instrumentation balloons \\ solar ...Assembly 4 Fig. 3 Solar Balloon Experiment Ass ’y 7 Fig. 4 Mechanical Interface , UV Spectrometer 8 Fig . 5 Spectrometer Body Assemb ly 10 Fig. 6...Diagram, GSE )bnitor 48 Selector and Battery Charger Fig. 25 Schematic Diagram, GSE Serial to 49 Parallel Data Converter Fig. 26 Schematic Diagram

  3. Determination of balloon drag

    NASA Technical Reports Server (NTRS)

    Conrad, George R.; Robbins, Edward J.

    1991-01-01

    The evolution of an empirical drag relationship that has stimulated rethinking regarding the physics of balloon drag phenomena is discussed. Combined parasitic drag from all sources in the balloon system are estimated to constitute less than 10 percent of the total system drag. It is shown that the difference between flight-determined drag coefficients and those based on the spherical assumption should be related to the square of the Froude number.

  4. Yellow Balloon in a Briar Patch.

    ERIC Educational Resources Information Center

    Cooper, Frank; Fitzmaurice, Robert W.

    1978-01-01

    As part of a meteorology unit, sixth grade science students launched helium balloons with attached return postcards. This article describes Weather Service monitoring of the balloons and postcard return results. (MA)

  5. 21 CFR 874.4100 - Epistaxis balloon.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    .... An epistaxis balloon is a device consisting of an inflatable balloon intended to control internal... (general controls). The device is exempt from the premarket notification procedures in subpart E of part...

  6. Auditory Risk of Exploding Hydrogen-Oxygen Balloons

    ERIC Educational Resources Information Center

    Gee, Kent L.; Vernon, Julia A.; Macedone, Jeffrey H.

    2010-01-01

    Although hydrogen-oxygen balloon explosions are popular demonstrations, the acoustic impulse created poses a hearing damage risk if the peak level exceeds 140 dB at the listener's ear. The results of acoustical measurements of hydrogen-oxygen balloons of varying volume and oxygen content are described. It is shown that hydrogen balloons may be…

  7. Balloon cell nevus of the iris.

    PubMed

    Morcos, Mohib W; Odashiro, Alexandre; Bazin, Richard; Pereira, Patricia Rusa; O'Meara, Aisling; Burnier, Miguel N

    2014-12-01

    Balloon cell nevus is a rare histopathological lesion characterized by a predominance of large, vesicular and clear cells, called balloon cells. There is only 1 case of balloon cell nevus of the iris reported in the literature. A 55 year-old man presented a pigmented elevated lesion in the right iris since the age of 12 years old. The lesion had been growing for the past 2 years and excision was performed. Histopathological examination showed a balloon cell nevus composed of clear and vacuolated cells without atypia. A typical spindle cell nevus of the iris was also observed. The differential diagnosis included xanthomatous lesions, brown adipocyte or other adipocytic lesions, clear cell hidradenoma, metastatic clear cell carcinoma of the kidney and clear cell sarcoma. The tumor was positive for Melan A, S100 protein and HMB45. Balloon cell nevus of the iris is rare but should be considered in the differential diagnosis of melanocytic lesions of the iris. Copyright © 2014 Elsevier GmbH. All rights reserved.

  8. Large eccentric laser angioplasty catheter

    NASA Astrophysics Data System (ADS)

    Taylor, Kevin D.; Reiser, Christopher

    1997-05-01

    In response to recent demand for increased debulking of large diameter coronary vascular segments, a large eccentric catheter for excimer laser coronary angioplasty has been developed. The outer tip diameter is 2.0 mm and incorporates approximately 300 fibers of 50 micron diameter in a monorail- type percutaneous catheter. The basic function of the device is to ablate a coronary atherosclerotic lesion with 308 nm excimer laser pulses, while passing the tip of the catheter through the lesion. By employing multiple passes through the lesion, rotating the catheter 90 degrees after each pass, we expect to create luminal diameters close to 3 mm with this device. Design characteristics, in-vitro testing, and initial clinical experience is presented.

  9. Minilaparotomy salvage of malfunctioning catheters in peritoneal dialysis.

    PubMed

    Li, Jian-Ri; Cheng, Chi-Hung; Chiu, Kun-Yuan; Cheng, Chen-Li; Yang, Chi-Rei; Ho, Hao-Chung; Ko, Jiunn-Liang; Ou, Yen-Chuan

    2013-01-01

    Catheter malfunction is a common and significant complication during peritoneal dialysis (PD). We developed a minilaparotomy procedure to rescue malfunctioning catheters and to prevent recurrence of malfunction. From 2006 to 2011, 11 patients receiving PD had a malfunctioning catheter. In all patients, a 2-cm incision, 5 cm caudally to the previous peritoneal entry site was used to correct the malfunctioning catheter, with concomitant fixation of the catheter to the peritoneum. Catheter tip migration occurred in 7 patients, omental wrapping in 3, and blood clot obstruction in 1. The mean onset time to catheter malfunction was 197.5 days (range: 4 - 1270 days), and the mean operating time was 41 minutes (range: 35 - 56 minutes). There was no recurrence of catheter malfunction and no surgery-related peritonitis. Our minilaparotomy procedure is safe and feasible for the salvage of malfunctioning PD catheters.

  10. The effect of peripherally inserted central catheter (PICC) valve technology on catheter occlusion rates--the 'ELeCTRiC' study.

    PubMed

    Johnston, Andrew J; Streater, Carmel T; Noorani, Remy; Crofts, Joanne L; Del Mundo, Aldwin B; Parker, Richard A

    2012-01-01

    Peripherally Inserted Central Catheters (PICCs) are increasingly being used to provide short to medium-term central venous access. The current study was designed to test the hypothesis that PICC valve technology does not influence PICC occlusion rates. Intensive care unit (ICU) patients who required a PICC were randomized to one of three types of dual lumen PICC (open ended non-valved, Groshong valve, PASV valve). PICC occlusions were recorded and managed with a protocol that used urokinase. A total of 102 patients were recruited to the study. The overall risk of occlusion per catheter was 35% (95% CI 26% to 44%). The overall rate of occlusion was 76 occlusions per 1000 catheter days (95% CI 61 to 95). Presence or type of valve did not significantly influence this rate (open-ended non-valved PICC 38% of catheters, 79 occlusions per 1000 catheter days; Groshong 38% of catheters, 60 occlusions per 1000 catheter days; PASV 27% of catheters, 99 occlusions per 1000 catheter days). The dose of urokinase required to treat PICC occlusions did not significantly differ between PICC types. Valved PICCs do not appear to influence PICC occlusion rates.

  11. The French Balloon Program 2013 - 2017

    NASA Astrophysics Data System (ADS)

    Dubourg, Vincent; Vargas, André; Raizonville, Philippe

    2016-07-01

    With over 50 years' experience in the field, the French Centre National d'Etudes Spatiales (CNES) goes on supporting - as designer and operator - a significant scientific ballooning program. In particular so because balloons still give a unique and valuable access to near space science. From 2008 to 2013, an important renovation effort was achieved, beginning by Zero Pressure Balloons (ZPB) systems, to comply with more stringent Safety constraints and to the growing reliability and performance requirements from scientific missions. The paper will give an overview of the CNES new capabilities and services for operational balloon activities, and their availability status. The scientific launch campaigns of the past two years will be presented. A focus will be made on the results of the Stratoscience 2015 flight campaign from Timmins, Ontario, using the NOSYCA command and control system for ZPB, qualified in flight in 2013. In particular, the PILOT telescope successfully flew during the 2015 campaign, key figures about the flight and mission will be given. An outlook of the new stratospheric long duration flight systems currently in process of developement at CNES will be given, as well as the presentation of the Stratéole 2 project, dedicated to the survey of the low stratosphere and upper troposphere in equatorial regions, with a fleet of small suprer pressure balloons (SPB). As far as tropospheric balloons are concerned, the Aeroclipper initiative will be presented, aiming at qualifying a quasi-tethered balloon, pushed by the winds close to the sea surface, for the study of cyclones. The scientific launch campaigns and the main payloads in the study for the near future will also be presented.

  12. Cerebrospinal Fluid Enhancement on Fluid Attenuated Inversion Recovery Images After Carotid Artery Stenting with Neuroprotective Balloon Occlusions: Hemodynamic Instability and Blood-Brain Barrier Disruption

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ogami, Ryo, E-mail: ogami.r@mazda.co.jp; Nakahara, Toshinori; Hamasaki, Osamu

    2011-10-15

    Purpose: A rare complication of carotid artery stenting (CAS), prolonged reversible neurological symptoms with delayed cerebrospinal fluid (CSF) space enhancement on fluid attenuated inversion recovery (FLAIR) images, is associated with blood-brain barrier (BBB) disruption. We prospectively identified patients who showed CSF space enhancement on FLAIR images. Methods: Nineteen patients-5 acute-phase and 14 scheduled-underwent 21 CAS procedures. Balloon catheters were navigated across stenoses, angioplasty was performed using a neuroprotective balloon, and stents were placed with after dilation under distal balloon protection. CSF space hyperintensity or obscuration on FLAIR after versus before CAS indicated CSF space enhancement. Correlations with clinical factors weremore » examined. Results: CSF space was enhanced on FLAIR in 12 (57.1%) cases. Postprocedural CSF space enhancement was significantly related to age, stenosis rate, acute-stage procedure, and total occlusion time. All acute-stage CAS patients showed delayed enhancement. Only age was associated with delayed CSF space enhancement in scheduled CAS patients. Conclusions: Ischemic intolerance for severe carotid artery stenosis and temporary neuroprotective balloon occlusion, causing reperfusion injury, seem to be the main factors that underlie BBB disruption with delayed CSF space enhancement shortly after CAS, rather than sudden poststenting hemodynamic change. Our results suggest that factors related to hemodynamic instability or ischemic intolerance seem to be associated with post-CAS BBB vulnerability. Patients at risk for hemodynamic instability or with ischemic intolerance, which decrease BBB integrity, require careful management to prevent intracranial hemorrhagic and other post-CAS complications.« less

  13. Vertical sounding balloons for stratospheric photochemistry

    NASA Astrophysics Data System (ADS)

    Pommereau, J. P.

    The use of vertical sounding balloons for stratospheric photochemistry studies is illustrated by the use of a vertical piloted gas balloon for the search of NO2 diurnal variations. It is shown that the use of montgolfieres (hot air balloons) can enhance the vertical sounding technique. Particular attention is given to a sun-heated montgolfiere and to the more sophisticated infrared montgolfiere that is able to perform three to four vertical excursions per day and to remain aloft for weeks or months.

  14. 21 CFR 870.1210 - Continuous flush catheter.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1210 Continuous flush catheter. (a) Identification. A continuous flush catheter is an attachment to a catheter-transducer system...

  15. 21 CFR 870.1210 - Continuous flush catheter.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1210 Continuous flush catheter. (a) Identification. A continuous flush catheter is an attachment to a catheter-transducer system...

  16. 21 CFR 870.1210 - Continuous flush catheter.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1210 Continuous flush catheter. (a) Identification. A continuous flush catheter is an attachment to a catheter-transducer system...

  17. Anti-fouling strategies for central venous catheters

    PubMed Central

    Albadawi, Hassan; Patel, Nikasha; Khademhosseini, Ali; Zhang, Yu Shrike; Naidu, Sailendra; Knuttinen, Grace; Oklu, Rahmi

    2017-01-01

    Central venous catheters (CVCs) are ubiquitous in the healthcare industry and carry two common complications, catheter related infections and occlusion, particularly by thrombus. Catheter-related bloodstream infections (CRBSI) are an important cause of nosocomial infections that increase patient morbidity, mortality, and hospital cost. Innovative design strategies for intravenous catheters can help reduce these preventable infections. Antimicrobial coatings can play a major role in preventing disease. These coatings can be divided into two major categories: drug eluting and non-drug eluting. Much of these catheter designs are targeted at preventing the formation of microbial biofilms that make treatment of CRBSI nearly impossible without removal of the intravenous device. Exciting developments in catheter impregnation with antibiotics as well as nanoscale surface design promise innovative changes in the way that physicians manage intravenous catheters. Occlusion of a catheter renders the catheter unusable and is often treated by tissue plasminogen activator administration or replacement of the line. Prevention of this complication requires a thorough understanding of the mechanisms of platelet aggregation, signaling and cross-linking. This article will look at the advances in biomaterial design specifically drug eluting, non-drug eluting, lubricious coatings and micropatterning as well as some of the characteristics of each as they relate to CVCs. PMID:29399528

  18. Anti-fouling strategies for central venous catheters.

    PubMed

    Wallace, Alex; Albadawi, Hassan; Patel, Nikasha; Khademhosseini, Ali; Zhang, Yu Shrike; Naidu, Sailendra; Knuttinen, Grace; Oklu, Rahmi

    2017-12-01

    Central venous catheters (CVCs) are ubiquitous in the healthcare industry and carry two common complications, catheter related infections and occlusion, particularly by thrombus. Catheter-related bloodstream infections (CRBSI) are an important cause of nosocomial infections that increase patient morbidity, mortality, and hospital cost. Innovative design strategies for intravenous catheters can help reduce these preventable infections. Antimicrobial coatings can play a major role in preventing disease. These coatings can be divided into two major categories: drug eluting and non-drug eluting. Much of these catheter designs are targeted at preventing the formation of microbial biofilms that make treatment of CRBSI nearly impossible without removal of the intravenous device. Exciting developments in catheter impregnation with antibiotics as well as nanoscale surface design promise innovative changes in the way that physicians manage intravenous catheters. Occlusion of a catheter renders the catheter unusable and is often treated by tissue plasminogen activator administration or replacement of the line. Prevention of this complication requires a thorough understanding of the mechanisms of platelet aggregation, signaling and cross-linking. This article will look at the advances in biomaterial design specifically drug eluting, non-drug eluting, lubricious coatings and micropatterning as well as some of the characteristics of each as they relate to CVCs.

  19. Balloon mania: news in the air.

    PubMed

    Kim, Mi Gyung

    2004-12-01

    The hot-air balloon, invented by the Montgolfier brothers in 1783, enabled the French King to project his glory, the nobility to exhibit their valor, the literary public to transmit the ideal of the Enlightenment and the plebian public to rejoice in a scientific spectacle. The ensuing balloon mania helped create an integrated public that, because of its size and composition, can only be described as 'democratic' just a few years before the French Revolution. The monumental impact of the balloon was well represented in a flood of poetry, pamphlets, books, journal reports, academic papers and consumer items. Sifting through these artifacts and considering the crowd that witnessed the ascent of the balloon will bring us to the historical moment when things, spectacles, and events (rather than words) shaped public and popular opinion.

  20. Outcomes after peritoneal dialysis catheter placement.

    PubMed

    Carpenter, Jennifer L; Fallon, Sara C; Swartz, Sarah J; Minifee, Paul K; Cass, Darrell L; Nuchtern, Jed G; Pimpalwar, Ashwin P; Brandt, Mary L

    2016-05-01

    The purpose of this study was to review surgical outcomes after elective placement of peritoneal dialysis (PD) catheters in children with end-stage renal disease. Children with PD catheters placed between February 2002 and July 2014 were retrospectively reviewed. Outcomes were catheter life, late (>30days post-op) complications (catheter malfunction, catheter malposition, infection), and re-operation rates. Comparison groups included laparoscopic versus open placement, age<2, and weight<10kg. Univariate and multivariate analysis were performed. One hundred sixteen patients had 173 catheters placed (122 open, 51 laparoscopic) with an average patient age of 9.7±6.3years. Mean catheter life was similar in the laparoscopic and open groups (581±539days versus 574±487days, p=0.938). The late complication rate was higher for open procedures (57% versus 37%, p=0.013). Children age<2 or weight<10kg had higher re-operation rates (64% versus 42%, p=0.014 and 73% versus 40%, p=0.001, respectively). Adjusted for age and weight, open technique remained a risk factor for late complications (OR 2.44, 95% CI 1.20-4.95) but not re-operation. Laparoscopic placement appears to reduce the rate of late complications in children who require PD dialysis catheters. Children <2years age or <10kg remain at risk for complications regardless of technique. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. Advanced Imaging Catheter: Final Project Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Krulevitch, P; Colston, B; DaSilva, L

    2001-07-20

    Minimally invasive surgery (MIS) is an approach whereby procedures conventionally performed with large and potentially traumatic incisions are replaced by several tiny incisions through which specialized instruments are inserted. Early MIS, often called laparoscopic surgery, used video cameras and laparoscopes to visualize and control the medical devices, which were typically cutting or stapling tools. More recently, catheter-based procedures have become a fast growing sector of all surgeries. In these procedures, small incisions are made into one of the main arteries (e.g. femoral artery in the thigh), and a long thin hollow tube is inserted and positioned near the target area.more » The key advantage of this technique is that recovery time can be reduced from months to a matter of days. In the United States, over 700,000 catheter procedures are performed annually representing a market of over $350 million. Further growth in this area will require significant improvements in the current catheter technology. In order to effectively navigate a catheter through the tortuous vessels of the body, two capabilities must exist: imaging and positioning. In most cases, catheter procedures rely on radiography for visualization and manual manipulation for positioning of the device. Radiography provides two-dimensional, global images of the vasculature and cannot be used continuously due to radiation exposure to both the patient and physician. Intravascular ultrasound devices are available for continuous local imaging at the catheter tip, but these devices cannot be used simultaneously with therapeutic devices. Catheters are highly compliant devices, and manipulating the catheter is similar to pushing on a string. Often, a guide wire is used to help position the catheter, but this procedure has its own set of problems. Three characteristics are used to describe catheter maneuverability: (1) pushability -- the amount of linear displacement of the distal end (inside body

  2. 21 CFR 870.1200 - Diagnostic intravascular catheter.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... intracardiac pressures, to sample blood, and to introduce substances into the heart and vessels. Included in this generic device are right-heart catheters, left-heart catheters, and angiographic catheters, among...

  3. 21 CFR 870.1200 - Diagnostic intravascular catheter.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... intracardiac pressures, to sample blood, and to introduce substances into the heart and vessels. Included in this generic device are right-heart catheters, left-heart catheters, and angiographic catheters, among...

  4. 21 CFR 870.1200 - Diagnostic intravascular catheter.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... intracardiac pressures, to sample blood, and to introduce substances into the heart and vessels. Included in this generic device are right-heart catheters, left-heart catheters, and angiographic catheters, among...

  5. 21 CFR 870.1200 - Diagnostic intravascular catheter.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... intracardiac pressures, to sample blood, and to introduce substances into the heart and vessels. Included in this generic device are right-heart catheters, left-heart catheters, and angiographic catheters, among...

  6. 21 CFR 870.1200 - Diagnostic intravascular catheter.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... intracardiac pressures, to sample blood, and to introduce substances into the heart and vessels. Included in this generic device are right-heart catheters, left-heart catheters, and angiographic catheters, among...

  7. [Incidence of phlebitis due to peripherally inserted venous catheters: impact of a catheter management protocol].

    PubMed

    Ferrete-Morales, C; Vázquez-Pérez, M A; Sánchez-Berna, M; Gilabert-Cerro, I; Corzo-Delgado, J E; Pineda-Vergara, J A; Vergara-López, S; Gómez-Mateos, J

    2010-01-01

    To assess the impact on the incidence of PPIVC by implementing a catheter management protocol and to determine risk factors for PPIVC development in hospitalized patients. A total of 3978 episodes of venous catheterization were prospectively included from September 2002 to December 2007. A catheter management protocol was implemented during this period of time. The incidence and variables associated to the occurrence of PPIVC were determined. The incidence of PPIVC from 2002 to 2007 was 4.8%, 4.3%, 3.6%, 2.5%, 1.3% and 1.8% (p<0.001). Perfusion of amiodarone [adjusted OR (AOR) 25.97; 95% CI=7.29-92.55, p=0.0001] and cefotaxime (AOR 2.90; 95% CI=1.29-6.52, p=0.01) and the shift when the catheters were placed (AOR for morning vs. night shift 0.60; 95% CI=0.35-1.02, p=0.063) were independently associated to the development of PPIVC. A history of phlebitis was the only factor independently associated to phlebitis due to peripherally inserted central venous catheters (AOR 3.24; CI at 95% CI= 1.05-9.98, p=0.04). A catheter management protocol decreases the incidence of PPIVC in hospitalized patients. The risk of PPIVC increases for peripherally inserted central venous catheters when the patients have a history of phlebitis and for peripheral venous catheters when amiodarone or cefotaxime are infused. Catheterization of peripheral veins performed during morning shifts is associated with a lower incidence of PPIVC when compared with night shift catheterizations.

  8. Application of Electrocautery Needle Knife Combined with Balloon Dilatation versus Balloon Dilatation in the Treatment of Tracheal Fibrotic Scar Stenosis.

    PubMed

    Bo, Liyan; Li, Congcong; Chen, Min; Mu, Deguang; Jin, Faguang

    Electrocautery needle knives can largely reduce scar and granulation tissue hyperplasia and play an important role in treating patients with benign stricture. The aim of this retrospective study was to evaluate the efficacy and safety of electrocautery needle knife combined with balloon dilatation versus balloon dilatation alone in the treatment of tracheal stenosis caused by tracheal intubation or tracheotomy. We retrospectively analysed the clinical data of 43 patients with tracheal stenosis caused by tracheotomy or tracheal intubation in our department from January 2013 to January 2016. Among these 43 patients, 23 had simple web-like stenosis and 20 had complex steno sis. All patients were treated under general anaesthesia, and the treatment methods were (1) balloon dilatation alone, (2) needle knife excision of fibrotic tissue combined with balloon dilatation, and (3) needle knife radial incision of fibrotic tissue combined with balloon dilatation. After treatment the symptoms, such as shortness of breath, were markedly improved immediately in all cases. The stenosis degree of patients who were treated with the elec-trocautery needle knife combined with balloon dilatation had better improvement compared with that of those treated with balloon dilatation treatment alone after 3 months (0.45 ± 0.04 vs. 0.67 ± 0.05, p < 0.01), and the proportion of restenosis occurrence that required further treatment was decreased at 6 months (46.9 vs. 81.8%), especially for the web-like stenosis patients, as most of their stenoses dilated with no obvious restenosis and achieved clinical cure. Electrocautery needle knife combined with balloon dilatation is an effective and safe treatment for tracheal fibrotic stenosis compared with balloon dilatation alone. © 2017 S. Karger AG, Basel.

  9. Novel Strategy for Temporary Decompression of the Lower Urinary Tract in Neonates Using a Ureteral Stent.

    PubMed

    Penna, Frank J; Bowlin, Paul; Alyami, Fahad; Bägli, Darius J; Koyle, Martin A; Lorenzo, Armando J

    2015-10-01

    In children with congenital obstructive uropathy, including posterior urethral valves, lower urinary tract decompression is recommended pending definitive surgical intervention. Current options, which are limited to a feeding tube or Foley catheter, pose unappreciated constraints in luminal diameter and are associated with potential problems. We assess the impact of luminal diameter on the current draining options and present a novel alternative method, repurposing a widely available stent that optimizes drainage. We retrospectively reviewed patients diagnosed with posterior urethral valves between January 2013 and December 2014. In all patients a 6Fr 12 cm Double-J ureteral stent was advanced over a guidewire in a retrograde fashion into the bladder. Luminal flow and cross-sectional areas were also assessed for each of 3 tubes for urinary drainage, ie 6Fr Double-J stent, 5Fr feeding tube and 6Fr Foley catheter. A total of 30 patients underwent uneventful bedside Double-J stent placement. Mean ± SD age at valve ablation was 28.5 ± 16.6 days. Mean ± SD peak serum creatinine was 2.23 ± 0.97 mg/dl after birth and 0.56 ± 0.22 mg/dl at the procedure. Urine output after stent placement was excellent in all patients. The Foley catheter and feeding tube drained approximately 18 and 6 times more slowly, respectively, and exhibited half the calculated cross-sectional luminal area compared to the Double-J stent. Use of Double-J stents in neonates with posterior urethral valves is a safe and effective alternative method for lower urinary tract decompression that optimizes the flow/lumen relationship compared to conventional drainage options. Copyright © 2015 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  10. Global electrodynamics from superpressure balloons

    NASA Technical Reports Server (NTRS)

    Holzworth, R. H.; Hu, H.

    1995-01-01

    Electric field and conductivity measurements in the stratosphere between November 1992 and March 1993 have been made using superpressure balloons in the southern hemisphere. Over 400 payload-days of data have been made during a record setting experiment called ELBBO (Extended Life Balloon Borne Observatories). This experiment resulted in 4 flights aloft simultaneously for over 2 months including one flight which lasted over 4 months. Electrodynamical coupling between the atmosphere and ionosphere is studied using the measured electric fields, and a simple empirical model of the stratospheric conductivity. Altitude profiles of conductivity have been obtained from several superpressure balloon flights using the large end-of-flight altitude swings on the last few days of each flight (as the balloon begins to loose superpressure). Coupling between the fields and atmospheric inertial waves has been observed. Effects and dynamics of the global circuit suggest that standard models are missing significant phenomena. Large scale ionospheric convection activity has been studied from the polar cap to the middle latitudes. Cusp latitude fields have been continuously measured for many days in a row.

  11. NASA Scientific Balloon in Antarctica

    NASA Image and Video Library

    2017-12-08

    NASA image captured December 25, 2011 A NASA scientific balloon awaits launch in McMurdo, Antarctica. The balloon, carrying Indiana University's Cosmic Ray Electron Synchrotron Telescope (CREST), was launched on December 25. After a circum-navigational flight around the South Pole, the payload landed on January 5. The CREST payload is one of two scheduled as part of this seasons' annual NASA Antarctic balloon Campaign which is conducted in cooperation with the National Science Foundation's Office of Polar Programs. The campaign's second payload is the University of Arizona's Stratospheric Terahertz Observatory (STO). You can follow the flights at the Columbia Scientific Balloon Facility's web site at www.csbf.nasa.gov/antarctica/ice.htm Credit: NASA NASA image use policy. NASA Goddard Space Flight Center enables NASA’s mission through four scientific endeavors: Earth Science, Heliophysics, Solar System Exploration, and Astrophysics. Goddard plays a leading role in NASA’s accomplishments by contributing compelling scientific knowledge to advance the Agency’s mission. Follow us on Twitter Like us on Facebook Find us on Instagram

  12. Complications of acucise endopyelotomy.

    PubMed

    Kim, F J; Herrell, S D; Jahoda, A E; Albala, D M

    1998-10-01

    Endoscopic management of ureteropelvic junction (UPJ) obstruction has a success rate of 80% to 86%. We have been performing a ureteral cutting balloon procedure under fluoroscopic control (Acucise endopyelotomy) for UPJ obstruction at Loyola University Medical Center since 1991. The overall success rate in 77 patients was 78%. All patients had a preoperative intravenous urogram or a retrograde pyelogram, but none had vascular imaging studies. Acucise endopyelotomy consisted of a posterolateral incision of the UPJ and placement of an endopyelotomy or double-J stent. Foley catheter placement at the end of the procedure demonstrated significant gross hematuria in three patients (4%). All three remained hemodynamically stable but with significant drops in postprocedure hemoglobin levels, which necessitated blood transfusion. Aggressive management included angiographic studies and embolization of lower-pole branching arteries in two patients (3%). One patient stopped bleeding after being given two units of blood. None of the patients required an open exploratory procedure. Although the risk of vascular injury is low with Acucise endopyelotomy, prolonged postoperative gross hematuria does mandate investigation and observation. Angiographic embolization appears to be the therapeutic modality of choice for patients with hemorrhagic complications after an Acucise endopyelotomy.

  13. Development of a Super-Pressure Balloon with an Improved Design

    NASA Astrophysics Data System (ADS)

    Izutsu, Naoki; Akita, Daisuke; Fuke, Hideyuki; Iijima, Issei; Kato, Yoichi; Kawada, Jiro; Matsushima, Kiyoho; Matsuzaka, Yukihiko; Mizuta, Eiichi; Nakada, Takashi; Nonaka, Naoki; Saito, Yoshitaka; Takada, Atsushi; Tamura, Keisuke; Yamada, Kazuhiko; Yoshida, Tetsuya

    A zero-pressure balloon used for scientific observation in the stratosphere has an unmanageable limitation that its floating altitude decreases during a nighttime because of temperature drop of the lifting gas. Since a super-pressure balloon may not change its volume, the lifetime can extend very long. We had introduced so called the ‘lobed-pumpkin’ type of super-pressure balloon that can realize a full-scale long-duration balloon and it will be in practical use in the very near future. As for larger super-pressure balloons, however, we still have some potential difficulties to be resolved. We here propose a new design suitable for a larger super-pressure balloon, which is roughly ‘lobed pumpkin with lobed cylinder’ and can adapt a single design for balloons of a wide range of volumes. Indoor inflation tests were successfully carried out with balloons designed and made by the method. It has been shown that the limit of the resisting pressure differential for a new designed balloon is same as that of a normal lobed-pumpkin balloon.

  14. Evolution of scientific ballooning and its impact on astrophysics research

    NASA Astrophysics Data System (ADS)

    Jones, William Vernon

    2014-05-01

    As we celebrate the centennial year of the discovery of cosmic rays on a manned balloon, it seems appropriate to reflect on the evolution of ballooning and its scientific impact. Balloons have been used for scientific research since they were invented in France more than 200 years ago. Ballooning was revolutionized in 1950 with the introduction of the so-called natural shape balloon with integral load tapes. This basic design has been used with more or less continuously improved materials for scientific balloon flights for more than a half century, including long-duration balloon (LDB) flights around Antarctica for the past two decades. The U.S. National Aeronautics and Space Administration (NASA) is currently developing the next generation super-pressure balloon that would enable extended duration missions above 99.5% of the Earth's atmosphere at any latitude. The Astro2010 Decadal Survey report supports super-pressure balloon development and the giant step forward it offers with ultra-long-duration balloon (ULDB) flights at constant altitudes for about 100 days.

  15. Prevention of catheter-related blood stream infection.

    PubMed

    Byrnes, Matthew C; Coopersmith, Craig M

    2007-08-01

    Catheter-related blood stream infections are a morbid complication of central venous catheters. This review will highlight a comprehensive approach demonstrated to prevent catheter-related blood stream infections. Elements of prevention important to inserting a central venous catheter include proper hand hygiene, use of full barrier precautions, appropriate skin preparation with 2% chlorhexidine, and using the subclavian vein as the preferred anatomic site. Rigorous attention needs to be given to dressing care, and there should be daily assessment of the need for central venous catheters, with prompt removal as soon as is practicable. Healthcare workers should be educated routinely on methods to prevent catheter-related blood stream infections. If rates remain higher than benchmark levels despite proper bedside practice, antiseptic or antibiotic-impregnated catheters can also prevent infections effectively. A recent program utilizing these practices in 103 ICUs in Michigan resulted in a 66% decrease in infection rates. There is increasing recognition that a comprehensive strategy to prevent catheter-related blood stream infections can prevent most infections, if not all. This suggests that thousands of infections can potentially be averted if the simple practices outlined herein are followed.

  16. Absorption spectrometer balloon flight and iodine investigations

    NASA Technical Reports Server (NTRS)

    1970-01-01

    A high altitude balloon flight experiment to determine the technical feasibility of employing absorption spectroscopy to measure SO2 and NO2 gases in the earth's atmosphere from above the atmospheric ozone layer is discussed. In addition to the balloon experiment the contract includes a ground-based survey of natural I emissions from geological sources and studies of the feasibility of mapping I2 from spacecraft. This report is divided into three major sections as follows: (1) the planning engineering and execution of the balloon experiment, (2) data reduction and analysis of the balloon data, and (3) the results of the I2 phase of the contract.

  17. Photoselective Vaporisation of the Bladder for the Management of Radiation Cystitis - Technique and Initial Outcomes.

    PubMed

    Pascoe, Claire; Christidis, Daniel; Manning, Todd; Lamb, Benjamin W; Murphy, Declan G; Lawrentschuk, Nathan

    2018-05-16

    Objective To describe our technique utilising photoselective vaporisation of the bladder (PVB) for the management of haemorrhagic cystitis and initial results of 12 patients. Materials and Method An audit of theatre records of a single surgeon was performed to identify patients who had undergone PVB for management of radiation-cystitis. Rigid cystoscopy was performed. Ureteric catheters were placed and active bleeding sites targeted to optimise vision. Ablation was commenced using the vaporize function. When lasering around delicate structures the coagulation function was used. Ureteric catheters remained in situ for 24h. An 18Fr Foley catheter was placed. When urine output was clear continuous bladder irrigation was ceased. Both uretetric catheters and Foley catheter were removed prior to the 24hour mark. Results 12 patients were identified. 8 had previously required blood transfusion secondary to bladder haemorrhage. 9 were successfully treated and 2 saw improvement in haematuria but required a repeat procedure at 3 weeks post operatively. 4 went on to receive hyperbaric oxygenation as consolidative therapy. 1 patient was unsuccessfully treated and went on to cystectomy. There were no mortalities. No patients sustained bladder perforation or damage to surrounding structures. Conclusion Radiation cystitis can be life threatening and remains a challenge for the urologist with traditional intra-vescical treatments such as aluminium or formalin having variable results. We present an alternate technique using PVB to ablate the bladder mucosa, with good results. Consolidation with hyperbaric oxygen therapy may be considered. Our study is limited by small sample size and the presence of bilateral ureteric catheters leaving the bladder free from urine may impact immediate post operative outcomes. These initial results are promising however further prospective evaluation with a larger cohort and pre and post operative cystograms would enable better evaluation of this

  18. Prevention of catheter-associated urinary tract infection

    PubMed Central

    Trautner, Barbara W.; Hull, Richard A.; Darouiche, Rabih O.

    2010-01-01

    Purpose of review The underlying cause of catheter-associated urinary tract infection is biofilm formation by uropathogens on the urinary catheter. Biofilm is a relatively new concept in medicine, and current measures to prevent biofilm formation are inadequate. Considerable work is being done in this area, but little clinical progress has been made. The purpose of this review is to analyze recent publications concerning prevention of catheter-associated urinary tract infection. Recent findings Several recent studies have elucidated aspects of biofilm formation in catheter-associated urinary tract infection. Other researchers are working on methods to disrupt biofilm formation on catheter surfaces. At the same time, the magnitude of the problem of catheter-associated urinary tract infection has increased awareness of the effectiveness of basic infection control measures. A modern approach to infection control may include computerized ordering systems that minimize unnecessary days of catheterization. Finally, consumption of cranberry juice products and bacterial interference are two novel approaches to urinary tract infection prevention. Summary Biofilm-disrupting strategies offer promise for the future but have little immediate applicability. Implementation of infection control measures to improve catheter function and remove unnecessary catheters can be done at the present time. In general, prevention of catheter-associated urinary tract infection remains an elusive goal. More basic research at the level of pathogenesis is needed so that novel strategies can be designed. PMID:15647698

  19. Aerodynamics of a Party Balloon

    ERIC Educational Resources Information Center

    Cross, Rod

    2007-01-01

    It is well-known that a party balloon can be made to fly erratically across a room, but it can also be used for quantitative measurements of other aspects of aerodynamics. Since a balloon is light and has a large surface area, even relatively weak aerodynamic forces can be readily demonstrated or measured in the classroom. Accurate measurements…

  20. FAQs about Catheter-Associated Urinary Tract Infection

    MedlinePlus

    ... and nurses take the following actions. Catheter insertion o Catheters are put in only when necessary and they are removed as soon as possible. o Only properly trained persons insert catheters using sterile (“ ...

  1. Concepts for autonomous flight control for a balloon on Mars

    NASA Technical Reports Server (NTRS)

    Heinsheimer, Thomas F.; Friend, Robyn C.; Siegel, Neil G.

    1988-01-01

    Balloons operating as airborne rovers have been suggested as ideal candidates for early exploration of the Martian surface. An international study team composed of scientists from the U.S.S.R., France, and the U.S.A. is planning the launching in 1994 of a balloon system to fly on Mars. The current likely design is a dual thermal/gas balloon that consists of a gas balloon suspended above a solar-heated thermal balloon. At night, the thermal balloon provides no lift, and the balloon system drifts just above the Martian surface; the lift of the gas balloon is just sufficient to prevent the science payload from hitting the ground. During the day, the balloon system flies at an altitude of 4 to 5 kilometers, rising due to the added lift provided by the thermal balloon. Over the course of a single Martian day, there may be winds in several directions, and in fact it can be expected that there will be winds simultaneously in different directions at different altitudes. Therefore, a balloon system capable of controlling its own altitude, via an autonomous flight control system, can take advantage of these different winds to control its direction, thereby greatly increasing both its mission utility and its longevity.

  2. Stratospheric Balloons for Planetary Science and the Balloon Observation Platform for Planetary Science (BOPPS) Mission Summary

    NASA Technical Reports Server (NTRS)

    Kremic, Tibor; Cheng, Andrew F.; Hibbitts, Karl; Young, Eliot F.; Ansari, Rafat R.; Dolloff, Matthew D.; Landis, Rob R.

    2015-01-01

    NASA and the planetary science community have been exploring the potential contributions approximately 200 questions raised in the Decadal Survey have identified about 45 topics that are potentially suitable for addressing by stratospheric balloon platforms. A stratospheric balloon mission was flown in the fall of 2014 called BOPPS, Balloon Observation Platform for Planetary Science. This mission observed a number of planetary targets including two Oort cloud comets. The optical system and instrumentation payload was able to provide unique measurements of the intended targets and increase our understanding of these primitive bodies and their implications for us here on Earth. This paper will discuss the mission, instrumentation and initial results and how these may contribute to the broader planetary science objectives of NASA and the scientific community. This paper will also identify how the instrument platform on BOPPS may be able to contribute to future balloon-based science. Finally the paper will address potential future enhancements and the expected science impacts should those enhancements be implemented.

  3. Central Venous Catheter (Central Line)

    MedlinePlus

    ... the skin entry site. With care, central venous catheters can remain in the body for several months without becoming infected. ■ ■ Blocking or kinking— Blood clots may begin to form in the catheter but ...

  4. Usefulness of gram staining of blood collected from total parenteral nutrition catheter for rapid diagnosis of catheter-related sepsis.

    PubMed Central

    Moonens, F; el Alami, S; Van Gossum, A; Struelens, M J; Serruys, E

    1994-01-01

    The accuracy of Gram staining of blood drawn from catheters used to administer total parenteral nutrition was compared with paired quantitative blood cultures for the diagnosis of catheter-related sepsis. Gram staining was positive in 11 of 18 episodes of catheter-related sepsis documented by quantitative culture (sensitivity, 61%) but in none of the 5 episodes of fever unrelated to catheter infection. Thus, this procedure enabled the rapid presumptive diagnosis and guidance of antimicrobial therapy for total parenteral nutrition catheter sepsis, with a positive predictive value of 100% and a negative predictive value of 42%. PMID:7521359

  5. NASA’s BARREL Mission Launches 20 Balloons

    NASA Image and Video Library

    2017-12-08

    A BARREL balloon floats into the sky as it is partially filled. When fully inflated, each balloon is 90 feet in diameter and carries an instrument suite that weighs 50 pounds. This is small for an Antarctica balloon launch, which can have balloons Typical balloons l the size of a football field with payloads of some 3,000 pounds. Credit: NASA --- In Antarctica in January, 2013 – the summer at the South Pole – scientists launched 20 balloons up into the air to study an enduring mystery of space weather: when the giant radiation belts surrounding Earth lose material, where do the extra particles actually go? The mission is called BARREL (Balloon Array for Radiation belt Relativistic Electron Losses) and it is led by physicist Robyn Millan of Dartmouth College in Hanover, NH. Millan provided photographs from the team’s time in Antarctica. The team launched a balloon every day or two into the circumpolar winds that circulate around the pole. Each balloon floated for anywhere from 3 to 40 days, measuring X-rays produced by fast-moving electrons high up in the atmosphere. BARREL works hand in hand with another NASA mission called the Van Allen Probes, which travels through the Van Allen radiation belts surrounding Earth. The belts wax and wane over time in response to incoming energy and material from the sun, sometimes intensifying the radiation through which satellites must travel. Scientists wish to understand this process better, and even provide forecasts of this space weather, in order to protect our spacecraft. As the Van Allen Probes were observing what was happening in the belts, BARREL tracked electrons that precipitated out of the belts and hurtled down Earth’s magnetic field lines toward the poles. By comparing data, scientists will be able to track how what’s happening in the belts correlates to the loss of particles – information that can help us understand this mysterious, dynamic region that can impact spacecraft. Having launched balloons in

  6. 21 CFR 884.5050 - Metreurynter-balloon abortion system.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Metreurynter-balloon abortion system. 884.5050... Devices § 884.5050 Metreurynter-balloon abortion system. (a) Identification. A metreurynter-balloon abortion system is a device used to induce abortion. The device is inserted into the uterine cavity...

  7. 21 CFR 884.5050 - Metreurynter-balloon abortion system.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Metreurynter-balloon abortion system. 884.5050... Devices § 884.5050 Metreurynter-balloon abortion system. (a) Identification. A metreurynter-balloon abortion system is a device used to induce abortion. The device is inserted into the uterine cavity...

  8. 21 CFR 884.5050 - Metreurynter-balloon abortion system.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Metreurynter-balloon abortion system. 884.5050... Devices § 884.5050 Metreurynter-balloon abortion system. (a) Identification. A metreurynter-balloon abortion system is a device used to induce abortion. The device is inserted into the uterine cavity...

  9. 21 CFR 884.5050 - Metreurynter-balloon abortion system.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Metreurynter-balloon abortion system. 884.5050... Devices § 884.5050 Metreurynter-balloon abortion system. (a) Identification. A metreurynter-balloon abortion system is a device used to induce abortion. The device is inserted into the uterine cavity...

  10. 21 CFR 884.5050 - Metreurynter-balloon abortion system.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Metreurynter-balloon abortion system. 884.5050... Devices § 884.5050 Metreurynter-balloon abortion system. (a) Identification. A metreurynter-balloon abortion system is a device used to induce abortion. The device is inserted into the uterine cavity...

  11. Investigating Diffusion and Entropy with Carbon Dioxide-Filled Balloons

    ERIC Educational Resources Information Center

    Jadrich, James; Bruxvoort, Crystal

    2010-01-01

    Fill an ordinary latex balloon with helium gas and you know what to expect. Over the next day or two the volume will decrease noticeably as helium escapes from the balloon. So what happens when a latex balloon is filled with carbon dioxide gas? Surprisingly, carbon dioxide balloons deflate at rates as much as an order of magnitude faster than…

  12. Dose Reduction Study in Vaginal Balloon Packing Filled With Contrast for HDR Brachytherapy Treatment;HDR; Uterine cervix cancer; Vaginal balloon packing; Contrast; Monte Carlo

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Saini, Amarjit S.; Zhang, Geoffrey G., E-mail: geoffrey.zhang@moffitt.org; Finkelstein, Steven E.

    2011-07-15

    Purpose: Vaginal balloon packing is a means to displace organs at risk during high dose rate brachytherapy of the uterine cervix. We tested the hypothesis that contrast-filled vaginal balloon packing reduces radiation dose to organs at risk, such as the bladder and rectum, in comparison to water- or air-filled balloons. Methods and Materials: In a phantom study, semispherical vaginal packing balloons were filled with air, saline solution, and contrast agents. A high dose rate iridium-192 source was placed on the anterior surface of the balloon, and the diode detector was placed on the posterior surface. Dose ratios were taken withmore » each material in the balloon. Monte Carlo (MC) simulations, by use of the MC computer program DOSXYZnrc, were performed to study dose reduction vs. balloon size and contrast material, including commercially available iodine- and gadolinium-based contrast agents. Results: Measured dose ratios on the phantom with the balloon radius of 3.4 cm were 0.922 {+-} 0.002 for contrast/saline solution and 0.808 {+-} 0.001 for contrast/air. The corresponding ratios by MC simulations were 0.895 {+-} 0.010 and 0.781 {+-} 0.010. The iodine concentration in the contrast was 23.3% by weight. The dose reduction of contrast-filled balloon ranges from 6% to 15% compared with water-filled balloon and 11% to 26% compared with air-filled balloon, with a balloon size range between 1.4 and 3.8 cm, and iodine concentration in contrast of 24.9%. The dose reduction was proportional to the contrast agent concentration. The gadolinium-based contrast agents showed less dose reduction because of much lower concentrations in their solutions. Conclusions: The dose to the posterior wall of the bladder and the anterior wall of the rectum can be reduced if the vaginal balloon is filled with contrast agent in comparison to vaginal balloons filled with saline solution or air.« less

  13. Bladder Diseases - Multiple Languages

    MedlinePlus

    ... Cantonese dialect) (繁體中文) French (français) Hindi (हिन्दी) Japanese (日本語) Korean (한국어) Russian (Русский) Somali (Af-Soomaali ) ... हिन्दी (Hindi) Bilingual PDF Health Information Translations Japanese (日本語) Expand Section Care of a Foley Catheter - ...

  14. Overview of the Scientific Balloon Activity in Sweden

    NASA Astrophysics Data System (ADS)

    Abrahamsson, Mattias; Kemi, Stig; Lockowandt, Christian; Andersson, Kent

    SSC, formerly known as Swedish Space Corporation, is a Swedish state-owned company working in several different space related fields, including scientific stratospheric balloon launches. Esrange Space Centre (Esrange in short) located in the north of Sweden is the launch facility of SSC, where both sounding rocket launches and stratospheric balloon launches are conducted. At Esrange there are also facilities for satellite communication, including one of the largest civilian satellite data reception stations in the world. Stratospheric balloons have been launched from Esrange since 1974, when the first flights were performed together with the French space agency CNES. These balloon flights have normally flown eastward either only over Sweden or into Finland. Some flights have also had permission to fly into Russia, as far as the Ural Mountains. Normal flight times are from 4 to 12 hours. These eastward flights are conducted during the winter months (September to May). Long duration flights have been flown from ESC since 2005, when NASA flew the BLAST payload from Sweden to north Canada. The prevailing westerly wind pattern is very advantageous for trans-Atlantic flights during summer (late May to late July). The long flight times are very beneficial for astronomical payloads, such as telescopes that need long observation times. In 2013 two such payloads were flown, the first called SUNRISE was a German/US solar telescope, and the other called PoGOLite with a Swedish gamma-ray telescope. In 14 days PoGOLite, which had permission to fly over Russia, made an almost complete circumpolar flight. Typical scientific balloon payload fields include atmospheric research, including research on ozone depletion, astronomical and cosmological research, and research in technical fields such as aerodynamics. University students from all over Europe are involved in flights from Esrange under a Swedish/German programme called BEXUS. Two stratospheric balloons are flown with student

  15. [Peripheral intravenous catheter-related phlebitis].

    PubMed

    van der Sar-van der Brugge, Simone; Posthuma, E F M Ward

    2011-01-01

    Phlebitis is a very common complication of the use of intravenous catheters. Two patients with an i.v. catheter complicated by thrombophlebitis are described. Patient A was immunocompromised due to chronic lymphatic leukaemia and developed septic thrombophlebitis with positive blood cultures for S. Aureus. Patient B was being treated with flucloxacillin because of an S. Aureus infection and developed chemical phlebitis. Septic phlebitis is rare, but potentially serious. Chemical or mechanical types of thrombophlebitis are usually less severe, but happen very frequently. Risk factors include: female sex, previous episode of phlebitis, insertion at (ventral) forearm, emergency placement and administration of antibiotics. Until recently, routine replacement of peripheral intravenous catheters after 72-96 h was recommended, but randomised controlled trials have not shown any benefit of this routine. A recent Cochrane Review recommends replacement of peripheral intravenous catheters when clinically indicated only.

  16. Simulating clefts in pumpkin balloons

    NASA Astrophysics Data System (ADS)

    Baginski, Frank; Brakke, Kenneth

    2010-02-01

    The geometry of a large axisymmetric balloon with positive differential pressure, such as a sphere, leads to very high film stresses. These stresses can be significantly reduced by using a tendon re-enforced lobed pumpkin-like shape. A number of schemes have been proposed to achieve a cyclically symmetric pumpkin shape, including the constant bulge angle (CBA) design, the constant bulge radius (CBR) design, CBA/CBR hybrids, and NASA’s recent constant stress (CS) design. Utilizing a hybrid CBA/CBR pumpkin design, Flight 555-NT in June 2006 formed an S-cleft and was unable to fully deploy. In order to better understand the S-cleft phenomenon, a series of inflation tests involving four 27-m diameter 200-gore pumpkin balloons were conducted in 2007. One of the test vehicles was a 1/3-scale mockup of the Flight 555-NT balloon. Using an inflation procedure intended to mimic ascent, the 1/3-scale mockup developed an S-cleft feature strikingly similar to the one observed in Flight 555-NT. Our analysis of the 1/3-scale mockup found it to be unstable. We compute asymmetric equilibrium configurations of this balloon, including shapes with an S-cleft feature.

  17. Catheter-based photoacoustic endoscope

    PubMed Central

    Yang, Joon-Mo; Li, Chiye; Chen, Ruimin; Zhou, Qifa; Shung, K. Kirk; Wang, Lihong V.

    2014-01-01

    Abstract. We report a flexible shaft-based mechanical scanning photoacoustic endoscopy (PAE) system that can be potentially used for imaging the human gastrointestinal tract via the instrument channel of a clinical video endoscope. The development of such a catheter endoscope has been an important challenge to realize the technique’s benefits in clinical settings. We successfully implemented a prototype PAE system that has a 3.2-mm diameter and 2.5-m long catheter section. As the instrument’s flexible shaft and scanning tip are fully encapsulated in a plastic catheter, it easily fits within the 3.7-mm diameter instrument channel of a clinical video endoscope. Here, we demonstrate the intra-instrument channel workability and in vivo animal imaging capability of the PAE system. PMID:24887743

  18. Retained intraaortic balloon. Case report and review of the literature.

    PubMed

    Grande, A M; Martinelli, L; Graffigna, A; Viganò, M

    1995-01-01

    We report a case of intraaortic balloon entrapment in a 70-year-old man who underwent emergency triple coronary bypass. Intraaortic balloon rupture caused the formation of a clot inside the balloon that eventually was responsible for the balloon's entrapment at the aortic bifurcation. The patient had severe atherosclerosis of the aorta and iliac arteries. Balloon removal required aorto-iliac exposure and aorto-bifemoral bypass. After 16 months, he is symptom free and at home.

  19. Incorporation of Scientific Ballooning into Science Education

    NASA Astrophysics Data System (ADS)

    Chanover, N.; Stochaj, S.; Petty, C.

    1999-12-01

    We are augmenting the science curriculum of the Roswell Independent School District in Roswell, NM, to take advantage of the proximity of a NASA scientific balloon base. The basic science related to balloon experimentation is being incorporated into the K-12 science curriculum via the discussion of topics such as atmospheric properties, weather, phases of matter, plotting skills, and communications in the context of a high-altitude balloon flight. These efforts will culminate in the construction of balloon-borne instruments by high school students, which will be launched during the spring of 2000. A demonstration flight, launched in the spring of 1999, was used to build student enthusiasm and community support for this program, which is funded by the NASA/IDEAS program.

  20. Nimbus 4/IRLS Balloon Interrogation Package (BIP)

    NASA Technical Reports Server (NTRS)

    1971-01-01

    The balloon interrogation package (BIP), an integral part of the overall interrogation, recording, and location subsystems (IRLS) for the Nimbus 4 program, is described. The BIP is a self-contained, integrated transponder designed to be carried aloft by a constant altitude, superpressure balloon to an altitude of 67,000 or 78,000 feet. After launch the BIP senses high-altitude balloon overpressure and temperature, and upon receipt of an interrogated command from the IRLS aboard the Nimbus 4 satellite, the BIP enodes the data on a real-time basis into a pulse-code modulation (PCM) format and transmits this data to the satellite. A summary of the program activity to produce 30 BIP systems and to support balloon launches from Ascension Island is presented.