Sample records for foot insulated subsurface

  1. Molten salt as a heat transfer fluid for heating a subsurface formation

    DOEpatents

    Nguyen, Scott Vinh; Vinegar, Harold J.

    2010-11-16

    A heating system for a subsurface formation includes a conduit located in an opening in the subsurface formation. An insulated conductor is located in the conduit. A material is in the conduit between a portion of the insulated conductor and a portion of the conduit. The material may be a salt. The material is a fluid at operating temperature of the heating system. Heat transfers from the insulated conductor to the fluid, from the fluid to the conduit, and from the conduit to the subsurface formation.

  2. Research on corrosion mechanism of suspension insulator steel foot of direct current system and measures for corrosion inhibition

    NASA Astrophysics Data System (ADS)

    Chen, He; Yang, Yueguang; Su, Guolei; Wang, Xiaoqing; Zhang, Hourong; Sun, Xiaoyu; Fan, Youping

    2017-09-01

    There are increasingly serious electrocorrosion phenomena on insulator hardware caused by direct current transmission due to the wide-range popularization of extra high voltage direct current transmission engineering in our country. Steel foot corrosion is the main corrosion for insulators on positive polarity side of transmission lines. On one hand, the corrosion leads to the tapering off of steel foot diameter, having a direct influence on mechanical property of insulators; on the other hand, in condition of corrosion on steel foot wrapped in porcelain ware, the volume of the corrosion product is at least 50% more than that of the original steel foot, leading to bursting of porcelain ware, threatening safe operation of transmission lines. Therefore, it is necessary to conduct research on the phenomenon and propose feasible measures for corrosion inhibition. Starting with the corrosion mechanism, this article proposes two measures for corrosion inhibition, and verifies the inhibition effect in laboratory conditions, providing reference for application in engineering.

  3. Impact and intrusion of the foot of a lizard running rapidly on sand

    NASA Astrophysics Data System (ADS)

    Li, Chen; Hsieh, Tonia; Umbanhowar, Paul; Goldman, Daniel

    2012-11-01

    The desert-dwelling zebra-tailed lizard (Callisaurus draconoides, 10 cm, 10 g) runs rapidly (~10 BL/s) on granular media (GM) like sand and gravel. On loosely packed GM, its large hind feet penetrate into the substrate during each step. Based on above-ground observation, a previous study (Li et al., JEB 2012) hypothesized that the hind foot rotated in the vertical plane subsurface to generate lift. To explain the observed center-of-mass dynamics, the model assumed that ground reaction force was dominated by speed-independent frictional drag. Here we use x-ray high speed video to obtain subsurface foot kinematics of the lizard running on GM, which confirms the hypothesized subsurface foot rotation following rapid foot impact at touchdown. However, using impact force measurements, a resistive force model, and the observed foot kinematics, we find that impact force during initial foot touchdown and speed-independent frictional drag during rotation only account for part of the required lift to support locomotion. This suggests that the rapid foot rotation further allows the lizard to utilize inertial forces from the local acceleration of the substrate (particles), similar to small robots running on GM (Qian et al., RSS 2012) and the basilisk (Jesus) lizard running on water.

  4. Effect of Sweating on Insulation of Footwear.

    PubMed

    Kuklane, Kalev; Holmér, Ingvar

    1998-01-01

    The study aimed to find out the influence of sweating on footwear insulation with a thermal foot model. Simultaneously, the influence of applied weight (35 kg), sock, and steel toe cap were studied. Water to 3 sweat glands was supplied with a pump at the rate of 10 g/hr in total. Four models of boots with steel toe caps were tested. The same models were manufactured also without steel toe. Sweating reduced footwear insulation 19-25% (30-37% in toes). During static conditions, only a minimal amount of sweat evaporated from boots. Weight affected sole insulation: Reduction depended on compressibility of sole material. The influence of steel toe varied with insulation. The method of thermal foot model appears to be a practical tool for footwear evaluation.

  5. Insulated conductor temperature limited heater for subsurface heating coupled in a three-phase WYE configuration

    DOEpatents

    Vinegar, Harold J.; Sandberg, Chester Ledlie

    2010-11-09

    A heating system for a subsurface formation is described. The heating system includes a first heater, a second heater, and a third heater placed in an opening in the subsurface formation. Each heater includes: an electrical conductor; an insulation layer at least partially surrounding the electrical conductor; and an electrically conductive sheath at least partially surrounding the insulation layer. The electrical conductor is electrically coupled to the sheath at a lower end portion of the heater. The lower end portion is the portion of the heater distal from a surface of the opening. The first heater, the second heater, and the third heater are electrically coupled at the lower end portions of the heaters. The first heater, the second heater, and the third heater are configured to be electrically coupled in a three-phase wye configuration.

  6. Study on electrochemical corrosion mechanism of steel foot of insulators for HVDC lines

    NASA Astrophysics Data System (ADS)

    Zheng, Weihua; Sun, Xiaoyu; Fan, Youping

    2017-09-01

    The main content of this paper is the mechanism of electrochemical corrosion of insulator steel foot in HVDC transmission line, and summarizes five commonly used artificial electrochemical corrosion accelerated test methods in the world. Various methods are analyzed and compared, and the simulation test of electrochemical corrosion of insulator steel feet is carried out by water jet method. The experimental results show that the experimental environment simulated by water jet method is close to the real environment. And the three suspension modes of insulators in the actual operation, the most serious corrosion of the V type suspension hardware, followed by the tension string suspension, and the linear string corrosion rate is the slowest.

  7. Non-ferromagnetic overburden casing

    DOEpatents

    Vinegar, Harold J.; Harris, Christopher Kelvin; Mason, Stanley Leroy

    2010-09-14

    Systems, methods, and heaters for treating a subsurface formation are described herein. At least one system for electrically insulating an overburden portion of a heater wellbore is described. The system may include a heater wellbore located in a subsurface formation and an electrically insulating casing located in the overburden portion of the heater wellbore. The casing may include at least one non-ferromagnetic material such that ferromagnetic effects are inhibited in the casing.

  8. Development of an artificial multifunctional foot: A project review

    NASA Astrophysics Data System (ADS)

    Almeida, João; Ferreira, Maria José; Lobarinhas, Pedro; Silva, Luís F.; Leite, Abílio; Araújo, Alfredo; Sousa, Fernando

    2013-10-01

    The main purpose of this project is the development of a multifunctional artificial foot, capable of duplicate a human foot in a laboratory environment, in order to evaluate and simulate footwear's performance under certain conditions. This foot is used as a laboratory prototype and is multisegmented, in order that each section is controlled independently in terms of heat generation and sweating rate, therefore it is possible to simulate more accurately the real behaviour of a human foot. The device produces thermal insulation values that will help to design footwear with better ability in terms of thermal comfort, replacing human volunteers in thermal comfort perception tests, which are very subjective. The prototype was already tested, and preliminary results indicated that thermal insulation values are within the range of expected values produced by other foot thermal manikins and by human volunteers' tests. This fact suggests that this lab prototype can be used infuture thermal comfort evaluations.

  9. Reusable LH2 tank technology demonstration through ground test

    NASA Technical Reports Server (NTRS)

    Bianca, C.; Greenberg, H. S.; Johnson, S. E.

    1995-01-01

    The paper presents the project plan to demonstrate, by March 1997, the reusability of an integrated composite LH2 tank structure, cryogenic insulation, and thermal protection system (TPS). The plan includes establishment of design requirements and a comprehensive trade study to select the most suitable Reusable Hydrogen Composite Tank system (RHCTS) within the most suitable of 4 candidate structural configurations. The 4 vehicles are winged body with the capability to deliver 25,000 lbs of payload to a circular 220 nm, 51.6 degree inclined orbit (also 40,000 lbs to a 28.5 inclined 150 nm orbit). A prototype design of the selected RHCTS is established to identify the construction, fabrication, and stress simulation and test requirements necessary in an 8 foot diameter tank structure/insulation/TPS test article. A comprehensive development test program supports the 8 foot test article development and involves the composite tank itself, cryogenic insulation, and integrated tank/insulation/TPS designs. The 8 foot diameter tank will contain the integrated cryogenic insulation and TPS designs resulting from this development and that of the concurrent lightweight durable TPS program. Tank ground testing will include 330 cycles of LH2 filling, pressurization, body loading, depressurization, draining, and entry heating.

  10. Frostbite

    MedlinePlus

    ... trapped between the layers of clothing acts as insulation against the cold. Wear windproof and waterproof outer ... liners that fit well, wick moisture and provide insulation. You might also try hand and foot warmers. ...

  11. 40 CFR Appendix C to Subpart Nnn... - Method for the Determination of Product Density

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... insulation. The method is applicable to all cured board and blanket products. 2. Equipment One square foot (12 in. by 12 in.) template, or templates that are multiples of one square foot, for use in cutting... procedure for the designated product. 3.2Cut samples using one square foot (or multiples of one square foot...

  12. 49 CFR 179.201-11 - Insulation.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Specifications for Non-Pressure Tank Car Tanks (Classes DOT-111AW and 115AW) § 179.201-11 Insulation. (a... Btu per hour, per square foot, per degree F. temperature differential. (b) [Reserved] ...

  13. 49 CFR 178.337-1 - General requirements.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... similar reflecting color on the upper two-thirds of area of the cargo tank. (e) Insulation. (1) Each cargo... suitable insulation of such thickness that the overall thermal conductance is not more than 0.08 Btu per square foot per °F differential per hour. The conductance must be determined at 60 °F. Insulation...

  14. 49 CFR 178.337-1 - General requirements.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... similar reflecting color on the upper two-thirds of area of the cargo tank. (e) Insulation. (1) Each cargo... suitable insulation of such thickness that the overall thermal conductance is not more than 0.08 Btu per square foot per °F differential per hour. The conductance must be determined at 60 °F. Insulation...

  15. 49 CFR 178.337-1 - General requirements.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... similar reflecting color on the upper two-thirds of area of the cargo tank. (e) Insulation. (1) Each cargo... suitable insulation of such thickness that the overall thermal conductance is not more than 0.08 Btu per square foot per °F differential per hour. The conductance must be determined at 60 °F. Insulation...

  16. 49 CFR 178.337-1 - General requirements.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... similar reflecting color on the upper two-thirds of area of the cargo tank. (e) Insulation. (1) Each cargo... suitable insulation of such thickness that the overall thermal conductance is not more than 0.08 Btu per square foot per °F differential per hour. The conductance must be determined at 60 °F. Insulation...

  17. 49 CFR 178.337-1 - General requirements.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... similar reflecting color on the upper two-thirds of area of the cargo tank. (e) Insulation. (1) Each cargo... suitable insulation of such thickness that the overall thermal conductance is not more than 0.08 Btu per square foot per °F differential per hour. The conductance must be determined at 60 °F. Insulation...

  18. 49 CFR 179.100-4 - Insulation.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Specifications for Pressure Tank Car Tanks (Classes DOT-105, 109, 112, 114 and 120) § 179.100-4 Insulation. (a..., per square foot, per degree F temperature differential. If exterior heaters are attached to tank, the...

  19. 49 CFR 179.200-4 - Insulation.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Specifications for Non-Pressure Tank Car Tanks (Classes DOT-111AW and 115AW) § 179.200-4 Insulation. (a) If... foot, per degree F temperature differential, unless otherwise provided in § 179.201-1. If exterior...

  20. 49 CFR 179.200-4 - Insulation.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ..., the tank shell and expansion dome when used must be insulated with an approved material. The entire... thermal conductance at 60 °F is not more than 0.225 Btu per hour, per square foot, per degree F...

  1. Open-celled polyurethane foam

    NASA Technical Reports Server (NTRS)

    Russell, L. W.

    1970-01-01

    Open-celled polyurethane foam has a density of 8.3 pounds per cubic foot and a compressive strength of 295 to 325 psi. It is useful as a porous spacer in layered insulation and as an insulation material in vacuum tight systems.

  2. Isolated ecosystems on supercooled scree slopes in subalpine environments - interaction between permafrost, soil and vegetation

    NASA Astrophysics Data System (ADS)

    Schwindt, Daniel; Kozák, Johanna-Luise; Kohlpaintner, Michael

    2017-04-01

    In the central European Alps, permafrost can be expected in altitudes above 2300 m a.s.l., where mean annual air temperatures are below -1°C. However, attributed to the thermally induced "chimney effect", isolated permafrost lenses can be found in scree slopes far below the timberline where mean annual air temperature is positive. Usually the supercooled subsurface appears as lenses at the foot of talus slopes, covered by a thick layer of organic material and a unique vegetation composition most obviously characterized by dwarf grown trees ("Hexenwäldli") and azonal plant species. The fact that mean annual air temperature is positive and therefore can be excluded as a driving factor makes these sites unique for studying interdependencies between a supercooled subsurface, plant adaptation and vegetation sociology as well as the soil development. Three study sites in the Swiss Alps, differing in altitude and substrate (granite, dolomite, limestone) were investigated. Studies covered the permafrost-affected central parts of the slope as well as the surrounding areas. For characterizing distribution and temporal variability of ground ice geophysical methods were applied (electrical resistivity- and seismic refraction tomography). Temperature data loggers were used for monitoring the thermal regime (air-, surface- and soil temperatures). Chemical parameters (pH, C/N ratio) and nutrient contents (N, P, Ca, Mg, Mn, K) were analyzed in different depth levels. Plant communities were analyzed with the Braun-Blanquet method. To characterize physiognomic adaptation of trees, transects have been determined parallel to slope, measuring tree height, diameter and age. Results show a strong spatial correlation between frozen ground, formation of a thick organic layer (Tangelhumus), azonal plant species distribution and pronounced dwarfing of trees. Surrounding areas with unfrozen subsurface show an - for the particular altitude - expected species and soil composition and normal forest growth. Ellenberg pointer values in central parts of the study sites showed a strong plant adaption to cold temperatures. However, plant sociological analysis did not indicate one clear azonal community, but two different permafrost-plant-communities, one adapted to acidic and the other to calcareous substrates. Dwarf grown trees (e.g. spruce, 63cm high, 122 years old) could be found in permafrost-affected areas of all study sites, while the same species developed normally in the surroundings. Main factor for the physiognomic adaptation seems to be the low temperature in the rooting zone and the correlated shorter vegetation period, as air temperatures and nutrient supplies between the permafrost affected area and its surroundings are comparable. Pronounced interdependencies between frozen ground distribution, vegetation cover and soil development could be verified for all sites. The supercooled subsurface causes reduced decomposition of organic material as well as dwarfing of trees. In return, Tangelhumus and dwarfed trees positively affect supercooling. Dry organic material thermally insulates the subsurface during summer and prevents/delays thawing, while the high thermal conductivity of the moist or frozen Tangelhumus enhances heat flow and supercooling in winter. In addition, dwarfed trees prevent the formation of a consistent insulating snow cover optimizing thermal fluxes between atmosphere and subsurface.

  3. Two technicians apply insulation to S-II second stage

    NASA Technical Reports Server (NTRS)

    1964-01-01

    Two technicians apply insulation to the outer surface of the S-II second stage booster for the Saturn V moon rocket. The towering 363-foot Saturn V was a multi-stage, multi-engine launch vehicle standing taller than the Statue of Liberty. Altogether, the Saturn V engines produced as much power as 85 Hoover Dams.

  4. Evaluation of three thermal protection systems in a hypersonic high-heating-rate environment induced by an elevon deflected 30 deg

    NASA Technical Reports Server (NTRS)

    Taylor, A. H.; Jackson, L. R.; Weinstein, I.

    1977-01-01

    Three thermal protection systems proposed for a hypersonic research airplane were subjected to high heating rates in the Langley 8 foot, high temperature structures tunnel. Metallic heat sink (Lockalloy), reusable surface insulation, and insulator-ablator materials were each tested under similar conditions. The specimens were tested for a 10 second exposure on the windward side of an elevon deflected 30 deg. The metallic heat sink panel exhibited no damage; whereas the reusable surface insulation tiles were debonded from the panel and the insulator-ablator panel eroded through its thickness, thus exposing the aluminum structure to the Mach 7 environment.

  5. Experimental study of surface insulated-standard hybrid tungsten planar wire array Z-pinches at "QiangGuang-I" facility

    NASA Astrophysics Data System (ADS)

    Sheng, Liang; Peng, Bodong; Li, Yang; Yuan, Yuan; Li, Mo; Zhang, Mei; Zhao, Chen; Zhao, Jizhen; Wang, Liangping

    2016-01-01

    The experimental results of the insulated-standard hybrid wire array Z pinches carried out on "QiangGuang-I" facility at Northwest Institute of Nuclear Technology were presented and discussed. The surface insulating can impose a significant influence on the dynamics and radiation characteristics of the hybrid wire array Z pinches, especially on the early stage (t/timp < 0.6). The expansion of insulated wires at the ablation stage is suppressed, while the streams stripped from the insulated wires move faster than that from the standard wires. The foot radiation of X-ray is enhanced by increment of the number of insulated wires, 19.6 GW, 33.6 GW, and 68.6 GW for shots 14037S, 14028H, and 14039I, respectively. The surface insulation also introduces nonhomogeneity along the single wire—the streams move much faster near the electrodes. The colliding boundary of the hybrid wire array Z pinches is bias to the insulated side approximately 0.6 mm.

  6. Evaluating an Exterior Insulation and Finish System for Deep Energy Retrofits

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dentz, Jordan; Podorson, David

    Exterior insulation and finish systems (EIFS) are proprietary synthetic formulations that are applied to the exterior walls of buildings to serve as insulation and exterior cladding. The insulation thickness can vary from less than one inch to a foot or more. In this project the applicability of EIFS for residential deep energy retrofits was investigated through modeling and a case study home. The home was retrofitted using a site-applied four-inch-thick EIFS. Site-specific details were developed as required for the residential retrofit application. Site work and the costs of the EIFS system were documented. The demonstration home was modeled using Buildingmore » Energy Optimization energy and cost analysis software to explore cost effectiveness of various EIFS insulation thicknesses in two climate locations.« less

  7. A decrease in heat insulation of the black-clawed brush-furred rat (Lophuromys melanonyx, Petter) during adaptation to high altitudes.

    PubMed

    Ivlev, Y F; Lavrenchenko, L A

    2016-01-01

    The results of the body-surface infrared thermography of rodents of the genus Lophuromys suggest that heat insulation of the black-clawed brush-furred rat L. melanonyx, a large specialized species of the AfroAlpine zone, is worse than that of the related smaller species, the golden-footed (L. chrysopus) and shorttailed (L. brevicaudus) brush-furred rats, that inhabit tropical forest and Erica shrub, respectively. A decrease in heat insulation of the alpine species may facilitate the use of solar radiation for supporting heat balance of these diurnal animals.

  8. Water-level altitudes 2011 and water-level changes in the Chicot, Evangeline, and Jasper aquifers and compaction 1973-2010 in the Chicot and Evangeline aquifers, Houston-Galveston region, Texas

    USGS Publications Warehouse

    Johnson, Michaela R.; Ramage, Jason K.; Kasmarek, Mark C.

    2011-01-01

    Most of the subsidence in the Houston–Galveston region has occurred as a direct result of groundwater withdrawals for municipal supply, industrial use, and irrigation that depressured and dewatered the Chicot and Evangeline aquifers causing compaction of the clay layers of the aquifer sediments. This report, prepared by the U.S. Geological Survey, in cooperation with the Harris–Galveston Subsidence District, City of Houston, Fort Bend Subsidence District, and Lone Star Groundwater Conservation District, is one in an annual series of reports depicting water-level altitudes and water-level changes in the Chicot, Evangeline, and Jasper aquifers and compaction in the Chicot and Evangeline aquifers in the Houston–Galveston region. The report contains maps showing 2011 water-level altitudes for the Chicot, Evangeline, and Jasper aquifers; maps showing 1-year (2010–11) water-level-altitude changes for each aquifer; maps showing 5-year (2006–11) water-level-altitude changes for each aquifer; maps showing long-term (1990–2011 and 1977–2011) water-level-altitude changes for the Chicot and Evangeline aquifers; a map showing long-term (2000–11) water-level-altitude change for the Jasper aquifer; a map showing locations of borehole extensometer sites; and graphs showing measured compaction of subsurface material at the extensometers from 1973, or later, through 2010. Tables listing the data used to construct each aquifer-data map and the compaction graphs are included.Water levels in the Chicot, Evangeline, and Jasper aquifers were measured during December 2010–February 2011. In 2011, water-level-altitude contours for the Chicot aquifer ranged from 200 feet below North American Vertical Datum of 1988 (hereinafter, datum) in a small area in southwestern Harris County to 200 feet above datum in central to southwestern Montgomery County. Water-level-altitude changes in the Chicot aquifer ranged from a 40-foot decline to a 33-foot rise (2010–11), from a 10-foot decline to an 80-foot rise (2006–11), from a 140-foot decline to a 100-foot rise (1990–2011), and from a 120-foot decline to a 200-foot rise (1977–2011). In 2011, water-level-altitude contours for the Evangeline aquifer ranged from 300 feet below datum in north-central Harris County to 200 feet above datum at the boundary of Waller, Montgomery, and Grimes Counties. Water-level-altitude changes in the Evangeline aquifer ranged from a 43-foot decline to a 73-foot rise (2010–11), from a 40-foot decline to a 160-foot rise (2006–11), from a 200-foot decline to a 240-foot rise (1990–2011), and from a 340-foot decline to a 260-foot rise (1977–2011). In 2011, water-level-altitude contours for the Jasper aquifer ranged from 200 feet below datum in south-central Montgomery County to 250 feet above datum in east-central Grimes County. Water-level-altitude changes in the Jasper aquifer ranged from a 45-foot decline to a 29-foot rise (2010–11), from a 90-foot decline to a 10-foot rise (2006–11), and from a 190-foot decline to no change (2000–11). Compaction of subsurface materials (mostly in the clay layers) composing the Chicot and Evangeline aquifers was recorded continuously at 13 borehole extensometers at 11 sites. For the period of record beginning in 1973, or later, and ending in December 2010, cumulative clay compaction data measured by 12 extensometers ranged from 0.100 foot at the Texas City–Moses Lake site to 3.544 foot at the Addicks site. The rate of compaction varies from site to site because of differences in groundwater withdrawals near each site and differences among sites in the clay-to-sand ratio in the subsurface materials. Therefore, it is not possible to extrapolate or infer a rate of clay compaction for an area based on the rate of compaction measured at a nearby extensometer.

  9. Environmental Assessment (EA) for the Comprehensive Range Plan (CRP), Melrose Air Force Range (AFR), New Mexico

    DTIC Science & Technology

    2011-07-01

    11,674 sq ft C-130 maintenance hangar with reinforced concrete footings, a foundation and footing slab, a structural steel frame, insulated metal...regional farming output significantly; however, it could potentially have a detrimental effect to the lessee. Environmental Justice – There are no...Facility – Construct a pre-engineered one story steel framed structure including the necessary concrete foundations to support the building.  SOF

  10. Water-level altitudes 2010 and water-level changes in the Chicot, Evangeline, and Jasper aquifers and compaction 1973-2009 in the Chicot and Evangeline aquifers, Houston-Galveston region, Texas

    USGS Publications Warehouse

    Kasmarek, Mark C.; Johnson, Michaela R.; Ramage, Jason K.

    2010-01-01

    Most of the subsidence in the Houston-Galveston region has occurred as a direct result of groundwater withdrawals for municipal supply, industrial use, and irrigation that depressured and dewatered the Chicot and Evangeline aquifers causing compaction of the clay layers of the aquifer sediments. This report, prepared by the U.S. Geological Survey, in cooperation with the Harris-Galveston Subsidence District, City of Houston, Fort Bend Subsidence District, and Lone Star Groundwater Conservation District, is one in an annual series of reports depicting water-level altitudes and water-level changes in the Chicot, Evangeline, and Jasper aquifers and compaction in the Chicot and Evangeline aquifers in the Houston-Galveston region. The report contains maps showing 2010 water-level altitudes for the Chicot, Evangeline, and Jasper aquifers, respectively; maps showing 1-year (2009-10) water-level-altitude changes for each aquifer; maps showing 5-year (2005-10) water-level-altitude changes for each aquifer; maps showing long-term (1990-2010 and 1977-2010) water-level-altitude changes for the Chicot and Evangeline aquifers; a map showing long-term (2000-10) water-level-altitude change for the Jasper aquifer; a map showing locations of borehole extensometer sites; and graphs showing measured compaction of subsurface material at the extensometers from 1973, or later, through 2009. Tables listing the data used to construct each aquifer-data map and the compaction graphs are included. Water levels in the Chicot, Evangeline, and Jasper aquifers were measured during December 2009-March 2010. In 2010, water-level-altitude contours for the Chicot aquifer ranged from 200 feet below National Geodetic Vertical Datum of 1929 or North American Vertical Datum of 1988 (hereinafter, datum) in a small area in southwestern Harris County to 200 feet above datum in central to southwestern Montgomery County. Water-level-altitude changes in the Chicot aquifer ranged from a 49-foot decline to a 67-foot rise (2009-10), from a 25-foot decline to a 35-foot rise (2005-10), from a 40-foot decline to an 80-foot rise (1990-2010), and from a 140-foot decline to a 200-foot rise (1977-2010). In 2010, water-level-altitude contours for the Evangeline aquifer ranged from 300 feet below datum in north-central Harris County to 200 feet above datum at the boundary of Waller, Montgomery, and Grimes Counties. Water-level-altitude changes in the Evangeline aquifer ranged from a 58-foot decline to a 69-foot rise (2009-10), from an 80-foot decline to an 80-foot rise (2005-10), from a 200-foot decline to a 220-foot rise (1990-2010), and from a 320-foot decline to a 220-foot rise (1977-2010). In 2010, water-level-altitude contours for the Jasper aquifer ranged from 200 feet below datum in south-central Montgomery County to 250 feet above datum in eastern-central Grimes County. Water-level-altitude changes in the Jasper aquifer ranged from a 39-foot decline to a 39-foot rise (2009-10), from a 110-foot decline to no change (2005-10), and from a 180-foot decline to no change (2000-10). Compaction of subsurface materials (mostly in the clay layers) composing the Chicot and Evangeline aquifers was recorded continuously at 13 borehole extensometers at 11 sites. For the period of record beginning in 1973, or later, and ending in December 2009, cumulative clay compaction data measured by 12 extensometers ranged from 0.088 foot at the Texas City-Moses Lake site to 3.559 foot at the Addicks site. The rate of compaction varies from site to site because of differences in groundwater withdrawals near each site and differences among sites in the clay-to-sand ratio in the subsurface materials. Therefore, it is not possible to extrapolate or infer a rate of clay compaction for an area based on the rate of compaction measured at a nearby extensometer.

  11. Experimental study of surface insulated-standard hybrid tungsten planar wire array Z-pinches at “QiangGuang-I” facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sheng, Liang; Peng, Bodong; Yuan, Yuan

    The experimental results of the insulated-standard hybrid wire array Z pinches carried out on “QiangGuang-I” facility at Northwest Institute of Nuclear Technology were presented and discussed. The surface insulating can impose a significant influence on the dynamics and radiation characteristics of the hybrid wire array Z pinches, especially on the early stage (t/t{sub imp} < 0.6). The expansion of insulated wires at the ablation stage is suppressed, while the streams stripped from the insulated wires move faster than that from the standard wires. The foot radiation of X-ray is enhanced by increment of the number of insulated wires, 19.6 GW, 33.6 GW, and 68.6 GWmore » for shots 14037S, 14028H, and 14039I, respectively. The surface insulation also introduces nonhomogeneity along the single wire—the streams move much faster near the electrodes. The colliding boundary of the hybrid wire array Z pinches is bias to the insulated side approximately 0.6 mm.« less

  12. Thermal Impact of Medium Deep Borehole Thermal Energy Storage on the Shallow Subsurface

    NASA Astrophysics Data System (ADS)

    Welsch, Bastian; Schulte, Daniel O.; Rühaak, Wolfram; Bär, Kristian; Sass, Ingo

    2017-04-01

    Borehole heat exchanger arrays are a well-suited and already widely applied method for exploiting the shallow subsurface as seasonal heat storage. However, in most of the populated regions the shallow subsurface also comprises an important aquifer system used for drinking water production. Thus, the operation of shallow geothermal heat storage systems leads to a significant increase in groundwater temperatures in the proximity of the borehole heat exchanger array. The magnitude of the impact on groundwater quality and microbiology associated with this temperature rise is controversially discussed. Nevertheless, the protection of shallow groundwater resources has priority. Accordingly, water authorities often follow restrictive permission policies for building such storage systems. An alternative approach to avoid this issue is the application of medium deep borehole heat exchanger arrays instead of shallow ones. The thermal impact on shallow aquifers can be significantly reduced as heat is stored at larger depth. Moreover, it can be further diminished by the installation of a thermally insulating materials in the upper section of the borehole heat exchangers. Based on a numerical simulation study, the advantageous effects of medium deep borehole thermal energy storage are demonstrated and quantified. A finite element software is used to model the heat transport in the subsurface in 3D, while the heat transport in the borehole heat exchangers is solved analytically in 1D. For this purpose, an extended analytical solution is implemented, which also allows for the consideration of a thermally insulating borehole section.

  13. Launch Vehicle Stage Adapter Move

    NASA Image and Video Library

    2017-08-24

    A NASA KAMAG transporter moves the Space Launch System’s launch vehicle stage adapter (LVSA) to an area where spray-on foam insulation will be applied. The LVSA recently completed manufacturing on a 30 foot welding tool at NASA’s Marshall Space Flight Center in Huntsville, Al. The LVSA will be coated with insulation that will protect it during it’s trip to space. The LVSA provides structural support and connects the core stage and the interim cryogenic propulsion stage during the first integrated flight of SLS and Orion.

  14. EVALUATION OF FROST HEAVE ON WASTE TRANSFER LINES WITH SHALLOW DEPTHS IN DST (DOUBLE SHELL TANK) FARMS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    HAQ MA

    2009-05-12

    The purpose of this document is to evaluate the effect of frost heave on waste transfer lines with shallow depths in DST farms. Because of the insulation, well compacted sandy material around waste transfer lines, the type of sandy and gravel soil, and relatively low precipitation at Hanford site, it is concluded that waste transfer lines with one foot of soil covers (sandy cushion material and insulation) are not expected to undergo frost heave damaging effects.

  15. Performance of LI-1542 Reusable Surface Insulation System in a Hypersonic Stream

    DTIC Science & Technology

    1974-04-01

    differential pressure loading across the panel. Facility The tests were conducted in the Langley 8-foot high-temperature "’!structures tunnel ( HTST ...is too long to be simulated in the relatively short test time of the 8-foot HTST ; therefore, the radiant-heat apparatus is used in sequence with the... HTST . Impact of these minute particles caused extensive crater damage to the tiles. A series of photos is shown in figure 20 to illustrate the

  16. Polyimide Foams Offer Superior Insulation

    NASA Technical Reports Server (NTRS)

    2012-01-01

    At Langley Research Center, Erik Weiser and his colleagues in the Advanced Materials and Processing Branch were working with a new substance for fabricating composites for use in supersonic aircraft. The team, however, was experiencing some frustration. Every time they tried to create a solid composite from the polyimide (an advanced polymer) material, it bubbled and foamed. It seemed like the team had reached a dead end in their research - until they had another idea. "We said, This isn t going to work for composites, but maybe we could make a foam out of it," Weiser says. "That was kind of our eureka moment, to see if we could go in a whole other direction. And it worked." Weiser and his colleagues invented a new kind of polyimide foam insulation they named TEEK. The innovation displayed a host of advantages over existing insulation options. Compared to other commercial foams, Weiser explains, polyimide foams perform well across a broad range of temperatures, noting that the NASA TEEK foams provide effective structural insulation up to 600 F and down to cryogenic temperatures. The foam does not burn or off-gas toxic fumes, and even at -423 F - the temperature of liquid hydrogen - the material stays flexible. The inventors could produce the TEEK foam at a range of densities, from 0.5 pounds per cubic foot up to 20 pounds per cubic foot, making the foam ideal for a range of applications, including as insulation for reusable launch vehicles and for cryogenic tanks and lines. They also developed a unique, friable balloon format for manufacturing the foam, producing it as hollow microspheres that allowed the foam to be molded and then cured into any desired shape - perfect for insulating pipes of different sizes and configurations. The team s originally unplanned invention won an "R&D 100" award, and a later form of the foam, called LaRC FPF-44 (Spinoff 2009), was named "NASA Invention of the Year" in 2007.

  17. KENNEDY SPACE CENTER, FLA. - United Space Alliance employee Anthony Simmons checks the electroweld he performed on an insulator inside a Reinforced Carbon Carbon panel. The gray carbon composite RCC panels are attached to the leading edge of the wing of the orbiters to withstand the aerodynamic forces experienced during launch and reentry, which can reach as high as 800 pounds per square foot. The operating range of RCC is from minus 250º F to about 3,000º F, the temperature produced by friction with the atmosphere during reentry.

    NASA Image and Video Library

    2003-09-16

    KENNEDY SPACE CENTER, FLA. - United Space Alliance employee Anthony Simmons checks the electroweld he performed on an insulator inside a Reinforced Carbon Carbon panel. The gray carbon composite RCC panels are attached to the leading edge of the wing of the orbiters to withstand the aerodynamic forces experienced during launch and reentry, which can reach as high as 800 pounds per square foot. The operating range of RCC is from minus 250º F to about 3,000º F, the temperature produced by friction with the atmosphere during reentry.

  18. KENNEDY SPACE CENTER, FLA. - United Space Alliance employee Anthony Simmons continues electrowelding on an insulator inside a Reinforced Carbon Carbon panel. The gray carbon composite RCC panels are attached to the leading edge of the wing of the orbiters to withstand the aerodynamic forces experienced during launch and reentry, which can reach as high as 800 pounds per square foot. The operating range of RCC is from minus 250º F to about 3,000º F, the temperature produced by friction with the atmosphere during reentry.

    NASA Image and Video Library

    2003-09-16

    KENNEDY SPACE CENTER, FLA. - United Space Alliance employee Anthony Simmons continues electrowelding on an insulator inside a Reinforced Carbon Carbon panel. The gray carbon composite RCC panels are attached to the leading edge of the wing of the orbiters to withstand the aerodynamic forces experienced during launch and reentry, which can reach as high as 800 pounds per square foot. The operating range of RCC is from minus 250º F to about 3,000º F, the temperature produced by friction with the atmosphere during reentry.

  19. KENNEDY SPACE CENTER, FLA. - United Space Alliance employee Anthony Simmons electrowelds a crack formed in the insulator inside a Reinforced Carbon Carbon panel. The gray carbon composite RCC panels are attached to the leading edge of the wing of the orbiters to withstand the aerodynamic forces experienced during launch and reentry, which can reach as high as 800 pounds per square foot. The operating range of RCC is from minus 250º F to about 3,000º F, the temperature produced by friction with the atmosphere during reentry.

    NASA Image and Video Library

    2003-09-16

    KENNEDY SPACE CENTER, FLA. - United Space Alliance employee Anthony Simmons electrowelds a crack formed in the insulator inside a Reinforced Carbon Carbon panel. The gray carbon composite RCC panels are attached to the leading edge of the wing of the orbiters to withstand the aerodynamic forces experienced during launch and reentry, which can reach as high as 800 pounds per square foot. The operating range of RCC is from minus 250º F to about 3,000º F, the temperature produced by friction with the atmosphere during reentry.

  20. KENNEDY SPACE CENTER, FLA. - United Space Alliance employee Anthony Simmons prepares to electroweld a crack formed in the insulator inside a Reinforced Carbon Carbon panel. The gray carbon composite RCC panels are attached to the leading edge of the wing of the orbiters to withstand the aerodynamic forces experienced during launch and reentry, which can reach as high as 800 pounds per square foot. The operating range of RCC is from minus 250º F to about 3,000º F, the temperature produced by friction with the atmosphere during reentry.

    NASA Image and Video Library

    2003-09-16

    KENNEDY SPACE CENTER, FLA. - United Space Alliance employee Anthony Simmons prepares to electroweld a crack formed in the insulator inside a Reinforced Carbon Carbon panel. The gray carbon composite RCC panels are attached to the leading edge of the wing of the orbiters to withstand the aerodynamic forces experienced during launch and reentry, which can reach as high as 800 pounds per square foot. The operating range of RCC is from minus 250º F to about 3,000º F, the temperature produced by friction with the atmosphere during reentry.

  1. KENNEDY SPACE CENTER, FLA. - United Space Alliance employee Anthony Simmons prepares to electroweld a crack found on an insulator inside a Reinforced Carbon Carbon panel. The gray carbon composite RCC panels are attached to the leading edge of the wing of the orbiters to withstand the aerodynamic forces experienced during launch and reentry, which can reach as high as 800 pounds per square foot. The operating range of RCC is from minus 250º F to about 3,000º F, the temperature produced by friction with the atmosphere during reentry.

    NASA Image and Video Library

    2003-09-16

    KENNEDY SPACE CENTER, FLA. - United Space Alliance employee Anthony Simmons prepares to electroweld a crack found on an insulator inside a Reinforced Carbon Carbon panel. The gray carbon composite RCC panels are attached to the leading edge of the wing of the orbiters to withstand the aerodynamic forces experienced during launch and reentry, which can reach as high as 800 pounds per square foot. The operating range of RCC is from minus 250º F to about 3,000º F, the temperature produced by friction with the atmosphere during reentry.

  2. In-Situ Air Sparaing: Engineering and Design

    DTIC Science & Technology

    2008-01-31

    Construction Materials. Although PVC casing is commonly used, flexible or rigid polyethylene pipe may be more efficient for certain excavation methods, such as...depth, etc.) Piping insulation/ heat tape installed Piping flushed/cleaned/pressure tested Subsurface as-built equipment...4-4 Figure 4-2 Pilot-Scale Piping and Instrumentation Diagram

  3. Saturn Apollo Program

    NASA Image and Video Library

    1964-03-03

    Two technicians apply insulation to the outer surface of the S-II second stage booster for the Saturn V moon rocket. The towering 363-foot Saturn V was a multi-stage, multi-engine launch vehicle standing taller than the Statue of Liberty. Altogether, the Saturn V engines produced as much power as 85 Hoover Dams.

  4. The birth of a dinosaur footprint: Subsurface 3D motion reconstruction and discrete element simulation reveal track ontogeny

    PubMed Central

    2014-01-01

    Locomotion over deformable substrates is a common occurrence in nature. Footprints represent sedimentary distortions that provide anatomical, functional, and behavioral insights into trackmaker biology. The interpretation of such evidence can be challenging, however, particularly for fossil tracks recovered at bedding planes below the originally exposed surface. Even in living animals, the complex dynamics that give rise to footprint morphology are obscured by both foot and sediment opacity, which conceals animal–substrate and substrate–substrate interactions. We used X-ray reconstruction of moving morphology (XROMM) to image and animate the hind limb skeleton of a chicken-like bird traversing a dry, granular material. Foot movement differed significantly from walking on solid ground; the longest toe penetrated to a depth of ∼5 cm, reaching an angle of 30° below horizontal before slipping backward on withdrawal. The 3D kinematic data were integrated into a validated substrate simulation using the discrete element method (DEM) to create a quantitative model of limb-induced substrate deformation. Simulation revealed that despite sediment collapse yielding poor quality tracks at the air–substrate interface, subsurface displacements maintain a high level of organization owing to grain–grain support. Splitting the substrate volume along “virtual bedding planes” exposed prints that more closely resembled the foot and could easily be mistaken for shallow tracks. DEM data elucidate how highly localized deformations associated with foot entry and exit generate specific features in the final tracks, a temporal sequence that we term “track ontogeny.” This combination of methodologies fosters a synthesis between the surface/layer-based perspective prevalent in paleontology and the particle/volume-based perspective essential for a mechanistic understanding of sediment redistribution during track formation. PMID:25489092

  5. KSC-2010-1114

    NASA Image and Video Library

    2010-01-07

    CAPE CANAVERAL, Fla. - The 525-foot-tall Vehicle Assembly Building, in the background, is witness to the formation of the Propellants North Administrative and Maintenance Facility, a new "green" building under construction in Launch Complex 39 at NASA's Kennedy Space Center in Florida. Concrete layers on either side of high-density foam insulation in the facility's walls will prevent any transfer of radiant heat between the exterior and interior of the buildings. A tilt-up construction method is being used to erect a THERMOMASS concrete wall insulation system for the facility's walls. In this approach, the exterior layer of concrete for the wall panels is poured and leveled on the building's footprint. Then, prefabricated, predrilled insulation sheets are arranged on top of the unhardened concrete, and connectors, designed to hold the sandwiched layers of concrete and insulation secure, are inserted through the predrilled holes. Next, the structural wythe is poured. Once cured, these panels are lifted upright to form the building's envelope. The facility will have a two-story administrative building to house managers, mechanics and technicians who fuel spacecraft at Kennedy adjacent to an 1,800-square-foot single-story shop to store cryogenic fuel transfer equipment. The new facility will feature high-efficiency roofs and walls, “Cool Dry Quiet” air conditioning with energy recovery technology, efficient lighting, and other sustainable features. The facility is striving to qualify for the U.S. Green Building Council’s Leadership in Energy and Environmental Design, or LEED, Platinum certification. If successful, Propellants North will be the first Kennedy facility to achieve this highest of LEED ratings after it is completed in the summer of 2010. The facility was designed for NASA by Jones Edmunds and Associates. Photo credit: NASA/Jim Grossmann

  6. Results of tests of advanced flexible insulation vortex and flow environments in the North American Aerodynamics Laboratory lowspeed wind tunnel using 0.0405-scale Space Shuttle Orbiter model 16-0 (test OA-309)

    NASA Technical Reports Server (NTRS)

    Marshall, B. A.; Nichols, M. E.

    1984-01-01

    An experimental investigation (Test OA-309) was conducted using 0.0405-scale Space Shuttle Orbiter Model 16-0 in the North American Aerodynamics Laboratory 7.75 x 11.00-foot Lowspeed Wind Tunnel. The primary purpose was to locate and study any flow conditions or vortices that might have caused damage to the Advanced Flexible Reusable Surface Insulation (AFRSI) during the Space Transportation System STS-6 mission. A secondary objective was to evaluate vortex generators to be used for Wind Tunnel Test OS-314. Flowfield visualization was obtained by means of smoke, tufts, and oil flow. The test was conducted at Mach numbers between 0.07 and 0.23 and at dynamic pressures between 7 and 35 pounds per square foot. The angle-of-attack range of the model was -5 degrees through 35 degrees at 0 or 2 degrees of sideslip, while roll angle was held constant at zero degrees. The vortex generators were studied at angles of 0, 5, 10, and 15 degrees.

  7. Solar project description for environmental partnership, Upper Freehold Township, Monmouth County, New Jersey

    NASA Astrophysics Data System (ADS)

    1982-08-01

    A solar house is described. It is a three-story single family detached residence in New Jersey. It is equipped with a 540 cubic foot vented Trombe wall constructed of concrete filled concrete blocks and glazed with 344 square feet of insulated tempered glass. Heat is also provided by a 168 square foot sunspace of insulated glass. In the loft area is a phase change storage system composed of 32 PSI Thermal-81 phase change storage rods. Auxiliary heating is y a wood-burning stove and a dual-fuel, propane and wood, forced air furnace. A breadbox type hot water preheater is located on the roof. Summer cooling is accomplished by opening windows, doors, and exhaust dampers and operating a whole house ventilation fan. Operation of the solar system and the auxiliary subsystems may involve one or more of 5 modes: collector-to-storage, storage-to-space heating, auxiliary-to-space heating, energy-to-load-summer cooling, and domestic hot water. The house, its solar heating systems, storage, load, operation, on-site performance evaluation instrumentation, and data depicting the solar portion of construction costs are outlined.

  8. Transonic stability and control characteristics of a 0.015 scale model 69-0 of the space shuttle orbiter with forebody RSI modification in the NASA/LaRC 8 foot TPT (LA72)

    NASA Technical Reports Server (NTRS)

    Ball, J. W.; Edwards, C. R.

    1976-01-01

    Tests were conducted in the NASA/LaRC 8 foot transonic wind tunnel from March 26 through 31, 1976. The model was a 0.015 scale SSV Orbiter with forebody modifications to simulate slight reductions in the reusable surface insulation (RSI) thickness. Six component aerodynamic force and moment data were obtained at Mach numbers from 0.35 to 1.20 over an angle of attack range from -2 deg to 20 deg at sideslip angles of 0 deg and 5 deg.

  9. Subsurface urban heat islands in German cities.

    PubMed

    Menberg, Kathrin; Bayer, Peter; Zosseder, Kai; Rumohr, Sven; Blum, Philipp

    2013-01-01

    Little is known about the intensity and extension of subsurface urban heat islands (UHI), and the individual role of the driving factors has not been revealed either. In this study, we compare groundwater temperatures in shallow aquifers beneath six German cities of different size (Berlin, Munich, Cologne, Frankfurt, Karlsruhe and Darmstadt). It is revealed that hotspots of up to +20K often exist, which stem from very local heat sources, such as insufficiently insulated power plants, landfills or open geothermal systems. When visualizing the regional conditions in isotherm maps, mostly a concentric picture is found with the highest temperatures in the city centers. This reflects the long-term accumulation of thermal energy over several centuries and the interplay of various factors, particularly in heat loss from basements, elevated ground surface temperatures (GST) and subsurface infrastructure. As a primary indicator to quantify and compare large-scale UHI intensity the 10-90%-quantile range UHII(10-90) of the temperature distribution is introduced. The latter reveals, in comparison to annual atmospheric UHI intensities, an even more pronounced heating of the shallow subsurface. Copyright © 2012 Elsevier B.V. All rights reserved.

  10. KSC-2010-1106

    NASA Image and Video Library

    2010-01-07

    CAPE CANAVERAL, Fla. - In Launch Complex 39 at NASA's Kennedy Space Center in Florida, the first wall of the Propellants North Administrative and Maintenance Facility is lifted into place. In the background is the 525-foot-tall Vehicle Assembly Building. A tilt-up construction method is being used to erect a THERMOMASS concrete wall insulation system for the facility's walls. In this approach, the exterior layer of concrete for the wall panels is poured and leveled on the building's footprint. Then, prefabricated, predrilled insulation sheets are arranged on top of the unhardened concrete, and connectors, designed to hold the sandwiched layers of concrete and insulation secure, are inserted through the predrilled holes. Next, the structural wythe is poured. Once cured, these panels are lifted upright to form the building's envelope. The facility will have a two-story administrative building to house managers, mechanics and technicians who fuel spacecraft at Kennedy adjacent to an 1,800-square-foot single-story shop to store cryogenic fuel transfer equipment. The new facility will feature high-efficiency roofs and walls, “Cool Dry Quiet” air conditioning with energy recovery technology, efficient lighting, and other sustainable features. The facility is striving to qualify for the U.S. Green Building Council’s Leadership in Energy and Environmental Design, or LEED, Platinum certification. If successful, Propellants North will be the first Kennedy facility to achieve this highest of LEED ratings after it is completed in the summer of 2010. The facility was designed for NASA by Jones Edmunds and Associates. Photo credit: NASA/Jim Grossmann

  11. Affordable Window Insulation with R-10/inch Rating

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jenifer Marchesi Redouane Begag; Je Kyun Lee; Danny Ou

    2004-10-15

    During the performance of contract DE-FC26-00-NT40998, entitled ''Affordable Window Insulation with R-10/inch Value'', research was conducted at Aspen Aerogels, Inc. to develop new transparent aerogel materials suitable for window insulation applications. The project requirements were to develop a formulation or multiple formulations that have high transparency (85-90%) in the visible region, are hydrophobic (will not opacify with exposure to water vapor or liquid), and have at least 2% resiliency (interpreted as recoverable 2% strain and better than 5% strain to failure in compression). Results from an unrelated project showed that silica aerogels covalently bonded to organic polymers exhibit excellent mechanicalmore » properties. At the outset of this project, we believed that such a route is the best to improve mechanical properties. We have applied Design of Experiment (DOE) techniques to optimize formulations including both silica aerogels and organically modified silica aerogels (''Ormosils''). We used these DOE results to optimize formulations around the local/global optimization points. This report documents that we succeeded in developing a number of formulations that meet all of the stated criteria. We successfully developed formulations utilizing a two-step approach where the first step involves acid catalyzed hydrolysis and the second step involves base catalyzed condensation to make the gels. The gels were dried using supercritical CO{sub 2} and we were able to make 1 foot x 1 foot x 0.5 inch panels that met the criteria established.« less

  12. Treatment of landfill leachate using an aerated, horizontal subsurface-flow constructed wetland.

    PubMed

    Nivala, J; Hoos, M B; Cross, C; Wallace, S; Parkin, G

    2007-07-15

    A pilot-scale subsurface-flow constructed wetland was installed at the Jones County Municipal Landfill, near Anamosa, Iowa, in August 1999 to demonstrate the use of constructed wetlands as a viable low-cost treatment option for leachate generated at small landfills. The system was equipped with a patented wetland aeration process to aid in removal of organic matter and ammonia nitrogen. The high iron content of the leachate caused the aeration system to cease 2 years into operation. Upon the installation of a pretreatment chamber for iron removal and a new aeration system, treatment efficiencies dramatically improved. Seasonal performance with and without aeration is reported for 5-day biochemical oxygen demand (BOD(5)), chemical oxygen demand (COD), ammonia nitrogen (NH(4)-N), and nitrate nitrogen (NO(3)-N). Since winter air temperatures in Iowa can be very cold, a layer of mulch insulation was installed on top of the wetland bed to keep the system from freezing. When the insulation layer was properly maintained (either through sufficient litterfall or replenishing the mulch layer), the wetland sustained air temperatures of as low as -26 degrees C without freezing problems.

  13. Black-footed ferrets and recreational shooting influence the attributes of black-tailed prairie dog burrows

    USGS Publications Warehouse

    Biggins, Dean E.; Ramakrishnan, Shantini; Goldberg, Amanda R.; Eads, David A.

    2012-01-01

    Black-tailed prairie dogs (Cynomys ludovicianus) plug burrows occupied by black-footed ferrets (Mustela nigripes), and they also plug burrows to entomb dead prairie dogs. We further evaluated these phenomena by sampling connectivity and plugging of burrow openings on prairie dog colonies occupied by ferrets, colonies where recreational shooting was allowed, and colonies with neither shooting nor ferrets. We counted burrow openings on line surveys and within plots, classified surface plugging, and used an air blower to examine subsurface connectivity. Colonies with ferrets had lower densities of openings, fewer connected openings (suggesting increased subsurface plugging), and more surface plugs compared to colonies with no known ferrets. Colonies with recreational shooting had the lowest densities of burrow openings, and line-survey data suggested colonies with shooting had intermediate rates of surface plugging. The extent of surface and subsurface plugging could have consequences for the prairie dog community by changing air circulation and escape routes of burrow systems and by altering energetic relationships. Burrow plugging might reduce prairie dogs' risk of predation by ferrets while increasing risk of predation by American badgers (Taxidea taxus); however, the complexity of the trade-off is increased if plugging increases the risk of predation on ferrets by badgers. Prairie dogs expend more energy plugging and digging when ferrets or shooting are present, and ferrets increase their energy expenditures when they dig to remove those plugs. Microclimatic differences in plugged burrow systems may play a role in flea ecology and persistence of the flea-borne bacterium that causes plague (Yersinia pestis).

  14. Space Shuttle Projects

    NASA Image and Video Library

    1991-07-01

    This photograph shows the Solid Propellant Test Article (SPTA) test stand with the Modified Nasa Motor (M-NASA) test article at the Marshall Space Flight Center (MSFC). The SPTA test stand, 12-feet wide by 12-feet long by 24-feet high, was built in 1989 to provide comparative performance data on nozzle and case insulation material and to verify thermostructural analysis models. A modified NASA 48-inch solid motor (M-NASA motor) with a 12-foot blast tube and 10-inch throat makes up the SPTA. The M-NASA motor is being used to evaluate solid rocket motor internal non-asbestos insulation materials, nozzle designs, materials, and new inspection techniques. New internal motor case instrumentation techniques are also being evaluated.

  15. Effects of superficial heating and insulation on walking speed in people with hereditary and spontaneous spastic paraparesis: A randomised crossover study.

    PubMed

    Denton, Amanda L; Hough, Alan D; Freeman, Jennifer A; Marsden, Jonathan F

    2018-03-01

    Cooling of the lower limb in people with Hereditary and Spontaneous Spastic Paraparesis (pwHSSP) has been shown to affect walking speed and neuromuscular impairments. The investigation of practical strategies, which may help to alleviate these problems is important. The potential of superficial heat to improve walking speed has not been explored in pwHSSP. Primary objective was to explore whether the application of superficial heat (hot packs) to lower limbs in pwHSSP improves walking speed. Secondary objective was to explore whether wearing insulation after heating would prolong any benefits. A randomised crossover study design with 21 pwHSSP. On two separate occasions two hot packs and an insulating wrap (Neo-G™) were applied for 30minutes to the lower limbs of pwHSSP. On one occasion the insulating wrap was maintained for a further 30minutes and on the other occasion it was removed. Measures of temperature (skin, room and core), walking speed (10 metre timed walk) and co-ordination (foot tap time) were taken at baseline (T1), after 30 mins (T2) and at one hour (T3). All 21 pwHSSP reported increased lower limb stiffness and decreased walking ability when their legs were cold. After thirty minutes of heating, improvements were seen in walking speed (12.2%, P<0.0001, effect size 0.18) and foot tap time (21.5%, P<0.0001, effect size 0.59). Continuing to wear insulation for a further 30minutes gave no additional benefit; with significant improvements in walking speed maintained at one hour (9.9%, P>0.001) in both conditions. Application of 30minutes superficial heating moderately improved walking speed in pwHSSP with effects maintained at 1hour. The use of hot packs applied to lower limbs should be the focus of further research for the clinical management of pwHSSP who report increased stiffness of limbs in cold weather and do not have sensory deficits. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  16. The Use of Ion Implantation for Materials Processing.

    DTIC Science & Technology

    1980-10-06

    consists of a series of sections, each section being an annular insulator (glass) and a shaped metal electrode (polished aluminum ) cemented together. A...depending on the ion species, semiconductor material, attached materials (such as aluminum leads), implantation energy, and dose; but some devices are...concentration of subsurface carbon. Appearing directly beneath the oxide layer, the C concentration first reaches a maximum of about five times the bulk

  17. SHIIVER_Interview_And_Move

    NASA Image and Video Library

    2017-08-10

    A technical challenge that NASA is working to solve is how to maintain super-cooled liquid propellants to be used as fuel for deep space missions. Heat intercept concepts such as advanced insulation blankets, foam insulation and vapor-based concepts will be evaluated with the Structural Heat Intercept Insulation Vibration Evaluation Rig or SHIIVER. The SHIIVER tank arrived Aug. 10 at NASA’s Marshall Space Flight Center in Huntsville, Alabama, for application of its first round of insulation. While at Marshall, the tank will have sensors installed. The team will then apply spray-on foam insulation (SOFI) to the 13-foot-long tank in Marshall’s Thermal Protection System Facility. A rotisserie-style fixture allows for even spraying of large objects. Following SOFI trimming, the tank will undergo a white-light scan to measure its final dimensions to assist with eventual Multi-Layer Insulation (MLI) application. The SOFI and MLI will reduce future propellant storage tank heat leak while on the launch pad where it is subject to atmospheric temperature and pressure conditions. After the spray-on foam insulation application, the tank will travel to Plum Brook Station in Sandusky, Ohio, which is managed by Glenn, for assembly, integration and testing in the B2 test chamber. The assembly will first undergo thermal vacuum testing with only SOFI on the tank surface. This will be the baseline heat load from which to assess future improvements. Then, the tank will be insulated on the top and bottom domes with MLI over the layer of SOFI and will undergo further cryogenic testing.

  18. Crack Initiation and Growth in Rigid Polymeric Closed-Cell Foam Cryogenic Applications

    NASA Technical Reports Server (NTRS)

    Sayyah, Tarek; Steeve, Brian; Wells, Doug

    2006-01-01

    Cryogenic vessels, such as the Space Shuttle External Tank, are often insulated with closed-cell foam because of its low thermal conductivity. The coefficient of thermal expansion mismatch between the foam and metallic substrate places the foam under a biaxial tension gradient through the foam thickness. The total foam thickness affects the slope of the stress gradient and is considered a significant contributor to the initiation of subsurface cracks. Rigid polymeric foams are brittle in nature and any subsurface cracks tend to propagate a finite distance toward the surface. This presentation investigates the relationship between foam thickness and crack initiation and subsequent crack growth, using linear elastic fracture mechanics, in a rigid polymeric closed-cell foam through analysis and comparison with experimental results.

  19. Barrier-free subsurface incorporation of 3 d metal atoms into Bi(111) films

    DOE PAGES

    Klein, C.; Vollmers, N. J.; Gerstmann, U.; ...

    2015-05-27

    By combining scanning tunneling microscopy with density functional theory it is shown that the Bi(111) surface provides a well-defined incorporation site in the first bilayer that traps highly coordinating atoms such as transition metals (TMs) or noble metals. All deposited atoms assume exactly the same specific sevenfold coordinated subsurface interstitial site while the surface topography remains nearly unchanged. Notably, 3 d TMs show a barrier-free incorporation. The observed surface modification by barrier-free subsorption helps to suppress aggregation in clusters. Thus, it allows a tuning of the electronic properties not only for the pure Bi(111) surface, but may also be observedmore » for topological insulators formed by substrate-stabilized Bi bilayers.« less

  20. 13-Foot Diameter Hydrogen Tank Tested in the K-Site Test Chamber

    NASA Image and Video Library

    1967-09-21

    A 13-foot diameter mounted inside the large test chamber at the Cryogenic Propellant Tank, or K-Site, at National Aeronautics and Space Administration’s (NASA) Plum Brook Station. The 25-foot test chamber and 20-foot access door were designed to test liquid hydrogen fuel tanks up to 18 feet in diameter in conditions that simulated launches and spaceflight. Shakers were installed to test the effects of launch vibration on the tanks and their insulation. The K Site chamber was also equipped with cold walls that could be cooled with either liquid nitrogen or liquid hydrogen and vacuum pumps that could reduce pressure levels to 10-8 torr. This 13-foot tank passed its initial acceptance tests in K-Site on August 24, 1966. Delays in the modification of the tank postponed further tests of the tank until May 1967. Four pressure hold tests and expulsion runs were made in May using gaseous hydrogen or gaseous helium at 300R and 520R. In June a straight pipe injector test was run and two pressure effect tests at 35 and 75psi. Propellant slosh tests were successfully run in August. This photograph was taken the day after the program’s final runs on September 12, 1967.

  1. Multi-functional foot use during running in the zebra-tailed lizard (Callisaurus draconoides).

    PubMed

    Li, Chen; Hsieh, S Tonia; Goldman, Daniel I

    2012-09-15

    A diversity of animals that run on solid, level, flat, non-slip surfaces appear to bounce on their legs; elastic elements in the limbs can store and return energy during each step. The mechanics and energetics of running in natural terrain, particularly on surfaces that can yield and flow under stress, is less understood. The zebra-tailed lizard (Callisaurus draconoides), a small desert generalist with a large, elongate, tendinous hind foot, runs rapidly across a variety of natural substrates. We use high-speed video to obtain detailed three-dimensional running kinematics on solid and granular surfaces to reveal how leg, foot and substrate mechanics contribute to its high locomotor performance. Running at ~10 body lengths s(-1) (~1 m s(-1)), the center of mass oscillates like a spring-mass system on both substrates, with only 15% reduction in stride length on the granular surface. On the solid surface, a strut-spring model of the hind limb reveals that the hind foot saves ~40% of the mechanical work needed per step, significant for the lizard's small size. On the granular surface, a penetration force model and hypothesized subsurface foot rotation indicates that the hind foot paddles through fluidized granular medium, and that the energy lost per step during irreversible deformation of the substrate does not differ from the reduction in the mechanical energy of the center of mass. The upper hind leg muscles must perform three times as much mechanical work on the granular surface as on the solid surface to compensate for the greater energy lost within the foot and to the substrate.

  2. Solid Propellant Test Article (SPTA) Test Stand

    NASA Technical Reports Server (NTRS)

    1991-01-01

    This photograph shows the Solid Propellant Test Article (SPTA) test stand with the Modified Nasa Motor (M-NASA) test article at the Marshall Space Flight Center (MSFC). The SPTA test stand, 12-feet wide by 12-feet long by 24-feet high, was built in 1989 to provide comparative performance data on nozzle and case insulation material and to verify thermostructural analysis models. A modified NASA 48-inch solid motor (M-NASA motor) with a 12-foot blast tube and 10-inch throat makes up the SPTA. The M-NASA motor is being used to evaluate solid rocket motor internal non-asbestos insulation materials, nozzle designs, materials, and new inspection techniques. New internal motor case instrumentation techniques are also being evaluated.

  3. Retrofits we`d rather forget

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hurrelbrinck, N.

    1996-01-01

    We all make mistakes, and the best of us make some of the biggest and best ones. An energy service company in New York installed light sensitive thermostats in a complex where the residents covered windows with heavy curtains to curtail air leakage. A crew in Chicago forgot to place a top plate in the top floor bathroom of a multifamily building; when they blew insulation into the roof, it filled the bathroom. A state official in the Midwest was inspecting the attic insulation in an FHA house when his foot slipped off the walk board and went through themore » ceiling drywall. And weatherization experts in Pittsburgh have discovered that a blower door can fill a house with decades` worth of accumulated soot. These mishaps could visit anyone. Much as those visited would rather bury them, we think they deserve an airing on the pages of Home Energy. In this issue, we present some cautionary tales from the elites of insulation.« less

  4. Space Shuttle Pressure Data Model in the 10- by 10-Foot Supersonic Wind Tunnel

    NASA Image and Video Library

    1978-04-21

    Technicians examine a scale model of the space shuttle used to obtain pressure data during tests in the 10- by 10-Foot Supersonic Wind Tunnel at the National Aeronautics and Space Administration (NASA) Lewis Research Center. Lewis researchers used the 10- by 10 tunnel extensively in the 1970s to study shuttle configurations in order to forecast conditions during an actual flight. These tests included analysis of the solid rocket boosters’ aerodynamics, orbiter forebody angle -of -attack and air speed, base heating for entire shuttle, and engine-out loads. The test seen in this photograph used a 3.5- percent scale aluminum alloy model of the entire launch configuration. The program was designed to obtain aerodynamic pressure data. The tests were part of a larger program to study possible trouble areas for the shuttle’s new Advanced Flexible Reusable Surface Insulation. The researchers obtained aeroacoustic data and pressure distributions from five locations on the model. Over 100 high-temperature pressure transducers were attached to the model. Other portions of the test program were conducted at Lewis’ 8- by 6-Foot Supersonic Wind Tunnel and the 11- by 11-Foot Transonic Wind Tunnel at Ames Research Center.

  5. Roof plan, Combat Operations Center, Building No. 2605. (Also includes ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Roof plan, Combat Operations Center, Building No. 2605. (Also includes a typical roof section, with new fiberglass and urethane insulation layers.) By Federal Builders, 575 Carreon Drive, Colton, California. Sheet 1 of 1, dated 18 May 1992. Scale one-eighth inch to one foot. 24x36 inches. ink on paper - March Air Force Base, Strategic Air Command, Combat Operations Center, 5220 Riverside Drive, Moreno Valley, Riverside County, CA

  6. Admittance Investigation of MIS Structures with HgTe-Based Single Quantum Wells.

    PubMed

    Izhnin, Ihor I; Nesmelov, Sergey N; Dzyadukh, Stanislav M; Voitsekhovskii, Alexander V; Gorn, Dmitry I; Dvoretsky, Sergey A; Mikhailov, Nikolaj N

    2016-12-01

    This work presents results of the investigation of admittance of metal-insulator-semiconductor structure based on Hg1 - x Cd x Te grown by molecular beam epitaxy. The structure contains a single quantum well Hg0.35Cd0.65Te/HgTe/Hg0.35Cd0.65Te with thickness of 5.6 nm in the sub-surface layer of the semiconductor. Both the conductance-voltage and capacitance-voltage characteristics show strong oscillations when the metal-insulator-semiconductor (MIS) structure with a single quantum well based on HgTe is biased into the strong inversion mode. Also, oscillations on the voltage dependencies of differential resistance of the space charge region were observed. These oscillations were related to the recharging of quantum levels in HgTe.

  7. Numerical modeling of subsurface communication

    NASA Astrophysics Data System (ADS)

    Burke, G. J.; Dease, C. G.; Didwall, E. M.; Lytle, R. J.

    1985-02-01

    Techniques are described for numerical modeling of through-the-Earth communication. The basic problem considered is evaluation of the field at a surface or airborne station due to an antenna buried in the Earth. Equations are given for the field of a point source in a homogeneous or stratified earth. These expressions involve infinite integrals over wave number, sometimes known as Sommerfield integrals. Numerical techniques used for evaluating these integrals are outlined. The problem of determining the current on a real antenna in the Earth, including the effect of insulation, is considered. Results are included for the fields of a point source in homogeneous and stratified earths and the field of a finite insulated dipole. The results are for electromagnetic propagation in the ELF-VLF range, but the codes also can address propagation problems at higher frequencies.

  8. Are There Oceans Under the Ice of Small Saturnian and Uranian Moons?

    NASA Astrophysics Data System (ADS)

    England, C.

    2003-05-01

    Thermal analysis of the large outer-planetary moons (Titan, Callisto, Ganymede) argue strongly for substantial subsurface oceans if they are made up mostly of rock and ice, and if the rock exhibits radioactivity not too different from that of meteoric and lunar material [1]. For Titania, Rhea, Oberon and Iapetus (the TROI moons) with radii just over 700 km, the existence of oceans is less clear. In these bodies, a subsurface ocean may be likely if the rock has sunk to the center of the moon (i.e., the moon is differentiated) and (1) the radiogenic heating rate is on the higher end of that of lunar samples, (2) the bodies experience tidal heating, or (3) the oceans contain compounds such as ammonia that reduce the freezing point of the aqueous environment. A combination of these occurrences would weigh for a subsurface ocean, perhaps of substantial size. That outer-planetary moons with radii larger than about 200 km (e.g.; Enceladus at 250 km) are spherical argues for separation of light and heavy materials, especially in the larger bodies. Otherwise, the moon exhibits an irregular shape (e.g.; Hyperion at 133 km). Primordial radioactivity and collision events may have aided separation. If present-day radiogenicity is that of lunar samples, natural heating is available to maintain global aqueous environments on all of the TROI moons. The ammonia-water eutectics suggested for Titan [2] provide additional margin. The maintenance of oceans in smaller bodies depends on a balance of internal heat generation and thermal isolation by ice or other insulating material. The more important parameter may be the insulating ice, without which an outer-planetary ocean is not possible. The reduced thermal conductivity for impure ice [3] provides even more likelihood for oceans. Calculations for tidal heating within Europa due to orbital resonances [4] suggest that tidal heating amounts to over 40 times its internal radiogenic heating. A value equal only to natural radiogenic heating would be sufficient to maintain aqueous systems within TROI moons. Subsurface aqueous oceans are likely on Titania, Rhea, Oberon and Iapetus, but will be buried more than 300 km under insulating icy layers. Their existence, and that of an environment favorable for life, may be detectable from surface features or from remote surveys of their internal electromagnetic properties. [1] England C, DPS MEETING #34 Abstract #41.08, 9/2002 [2] Lorenz RD, Lunine JI, McKay CP, ENANTIOMER 6 (2-3): 83-96 2001 [3] Lorenz RD and Shandera SE, GEOPHYSICAL RESEARCH LETTERS 28 (2) 215-218 2001 [4] Ross MN, Schubert G, LUNAR AND PLANETARY SCIENCE XVII, PP. 724-725, 1986

  9. An effective model for LaTiO3 using first principles quantum Monte Carlo

    NASA Astrophysics Data System (ADS)

    Williams, Kiel; Wagner, Lucas

    The rare earth perovskites have long been of interest due in part to the interplay of their geometries and electronic properties. The perovskite LaTiO3 in particular is an antiferromagnetic insulator with a small 0.2 eV band gap that displays the GdFeO3 distortion at ambient pressure. We apply a new technique to derive an effective model for LaTiO3 as a function of the distortion. Since this technique treats one and two-body degrees of freedom on an equal footing, we use it to evaluate the evolution of effective model parameters with changes in the lattice. We will report on the progress in assessing whether the insulating nature is due to the distortion, or vice versa.

  10. Behavior of uranium under conditions of interaction of rocks and ores with subsurface water

    NASA Astrophysics Data System (ADS)

    Omel'Yanenko, B. I.; Petrov, V. A.; Poluektov, V. V.

    2007-10-01

    The behavior of uranium during interaction of subsurface water with crystalline rocks and uranium ores is considered in connection with the problem of safe underground insulation of spent nuclear fuel (SNF). Since subsurface water interacts with crystalline rocks formed at a high temperature, the mineral composition of these rocks and uranium species therein are thermodynamically unstable. Therefore, reactions directed toward the establishment of equilibrium proceed in the water-rock system. At great depths that are characterized by hindered water exchange, where subsurface water acquires near-neutral and reducing properties, the interaction is extremely sluggish and is expressed in the formation of micro- and nanoparticles of secondary minerals. Under such conditions, the slow diffusion redistribution of uranium with enrichment in absorbed forms relative to all other uranium species is realized as well. The products of secondary alteration of Fe- and Ti-bearing minerals serve as the main sorbents of uranium. The rate of alteration of minerals and conversion of uranium species into absorbed forms is slow, and the results of these processes are insignificant, so that the rocks and uranium species therein may be regarded as unaltered. Under reducing conditions, subsurface water is always saturated with uranium. Whether water interacts with rock or uranium ore, the equilibrium uranium concentration in water is only ≤10-8 mol/l. Uraninite ore under such conditions always remains stable irrespective of its age. The stability conditions of uranium ore are quite suitable for safe insulation of SNF, which consists of 95% uraninite (UO2) and is a confinement matrix for all other radionuclides. The disposal of SNF in massifs of crystalline rocks at depths below 500 m, where reducing conditions are predominant, is a reliable guarantee of high SNF stability. Under oxidizing conditions of the upper hydrodynamic zone, the rate of interaction of rocks with subsurface water increases by orders of magnitude and subsurface water is commonly undersaturated with uranium. Uranium absorbed by secondary minerals, particularly by iron hydroxides and leucoxene, is its single stable species under oxidizing conditions. The impact of oxygen-bearing water leads to destruction of uranium ore. This process is realized simultaneously at different hypsometric levels even if the permeability of the medium is variable in both the lateral and vertical directions. As a result, intervals containing uranyl minerals and relics of primary uranium ore are combined in ore-bearing zones with intervals of completely dissolved uranium minerals. A wide halo of elevated uranium contents caused by sorption is always retained at the location of uranium ore entirely destroyed by weathering. Uranium ore commonly finds itself in the aeration zone due to technogenic subsidence of the groundwater table caused by open-pit mining or pumping out of water from underground mines. The capillary and film waters that interact with rocks and ores in this zone are supplemented by free water filtering along fractures when rain falls or snow is thawing. The interaction of uranium ore with capillary water results in oxidation of uraninite, accompanied by loosening of the mineral surface, formation of microfractures, and an increase in solubility with enrichment of capillary water in uranium up to 10-4 mol/l. Secondary U(VI) minerals, first of all, uranyl hydroxides and silicates, replace uraninite, and uranium undergoes local diffusion redistribution with its sorption by secondary minerals of host rocks. The influx of free water facilitates the complete dissolution of primary and secondary uranium minerals, the removal of uranium at the sites of groundwater discharge, and its redeposition under reducing conditions at a greater depth. It is evident that the conditions of the upper hydrodynamic zone and the aeration zone are unfit for long-term insulation of SNF and high-level wastes because, after the failure of containers, the leakage of radionuclides into the environment becomes inevitable.

  11. Method for determination of .sup.18 O/.sup.16 O and .sup.2 H/.sup.1 H ratios and .sup.3 H (tritium) concentrations of xylem waters and subsurface waters using time series sampling

    DOEpatents

    Smith, Brian; Menchaca, Leticia

    1999-01-01

    A method for determination of .sup.18 O/.sup.16 O and .sup.2 H/.sup.1 H ratios and .sup.3 H concentrations of xylem and subsurface waters using time series sampling, insulating sampling chambers, and combined .sup.18 O/.sup.16 O, .sup.2 H/.sup.1 H and .sup.3 H concentration data on transpired water. The method involves collecting water samples transpired from living plants and correcting the measured isotopic compositions of oxygen (.sup.18 O/.sup.16 O) and hydrogen (.sup.2 H/.sup.1 H and/or .sup.3 H concentrations) to account for evaporative isotopic fractionation in the leafy material of the plant.

  12. Numerical modeling of subsurface communication, revision 1

    NASA Astrophysics Data System (ADS)

    Burke, G. J.; Dease, C. G.; Didwall, E. M.; Lytle, R. J.

    1985-08-01

    Techniques are described for numerical modeling of through-the-Earth communication. The basic problem considered is evaluation of the field at a surface or airborne station due to an antenna buried in the earth. Equations are given for the field of a point source in a homogeneous or stratified Earth. These expressions involve infinite integrals over wave number, sometimes known as Sommerfeld integrals. Numerical techniques used for evaluating these integrals are outlined. The problem of determining the current on a real antenna in the Earth, including the effect of insulation, is considered. Results are included for the fields of a point source in homogeneous and stratified earths and the field of a finite insulated dipole. The results are for electromagnetic propagation in the ELF-VLF range, but the codes also can address propagation problems at higher frequencies.

  13. Evacuated load-bearing high performance insulation study

    NASA Technical Reports Server (NTRS)

    Parmley, R. T.; Cunnington, G. R.

    1977-01-01

    A light weight, vacuum jacketed, load bearing cryogenic insulation system was developed and tested on a 1.17-m (46-in.) spherical test tank. The vacuum jacket consists of 0.08 mm (0.003 in.) thick 321 stainless steel formed into a wedge design that allows elastic jacket movements as the tank shrinks (cools) or expands (warms up or is pressurized). Hollow glass spheres, approximately 80 micrometers in diameter with a bulk density of 0.069 g/cc (4.3 lb cubic foot), provide the insulating qualities and one atmosphere load bearing capability required. The design, fabrication, and test effort developed the manufacturing methods and engineering data needed to scale the system to other tank sizes, shapes, and applications. The program demonstrated that thin wall jackets can be formed and welded to maintain the required vacuum level of .013 Pa yet flex elastically for multiple reuses. No significant shifting or breakage of the microspheres occurred after 13 simulated Space Tug flight cycles on the test tank and a hundred 1 atmosphere load cycles in a flat plate calorimeter. The test data were then scaled to the Space Tug LO2 and LH2 tanks, and weight, thermal performance, payload performance, and costs were compared with a helium purged multilayer insulation system.

  14. Polysil shows promise. [Made by combining silica or ground rock (90%), an organic binder, and reinforcing fibers (10%)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1978-04-01

    A new synthetic, Polysil, promises to be half as costly to produce and even more suitable than porcelain as an outdoor insulating material for electric power equipment. Developed by the Electric Power Research Institute (EPRI), the polymer-silica compound has twice as much dielectric strength and half as much dielectric constant as porcelain. It also has design flexibility and is more resistant to impact. As a derivative of polymer concrete with six to eight times the strength of concrete, it has been successfully used for erosion control around dams and power plants. Production is simple and can be decentralized. Metal insertsmore » can be cast into the insulators rather than attaching separate end caps to lower costs and reduce contamination. Field testing on Polysil will continue for several years to test application for disconnect switches in residential areas; to use as a structural form in substations and eliminate insulators; to encase underground transmission conductors; and for circuit breakers and tower footings. Utilities will be looking for confirmation of polysil's durability and performance before making an extensive commitment.« less

  15. How to create ball lightning

    NASA Technical Reports Server (NTRS)

    Golka, Robert K., Jr.

    1991-01-01

    Procedures are given on how to produce ball lightning. Necessary equipment includes a transformer of 150,000 watts capable of providing approximately 10,000 amperes at 15 volts, 60 cycles; thick one inch cables of stranded wire leading into a 3 by 4 by 1 foot plastic tank; a quarter inch thick 4 by 6 inch aluminum plate to be used as one of the discharge electrodes; and another electrode of heavy copper wire with the insulation stripped back 6 inches.

  16. Space Launch System Launch Vehicle Stage Adapter Hardware Completes Manufacturing

    NASA Image and Video Library

    2017-08-28

    The Launch Vehicle Stage Adapter for the first flight of the Space Launch System, NASA’s new deeps space rocket, recently completed manufacturing at NASA’s Marshal Space Flight Center in Huntsville, Alabama. The LVSA, the largest piece of the rocket welded together in Marshall’s Huntsville manufacturing area, will connect two major sections of SLS – the 27.6-foot diameter core stage and the 16.4-foot interim cryogenic propulsion stage – for the first integrated flight of SLS and the Orion spacecraft. Teledyne Brown Engineering of Huntsville, the prime contractor for the adapter, has completed manufacturing, and engineers are preparing to apply thermal insulation. It will be the largest piece of hardware that Marshall. The LVSA was moved from the NASA welding area to NASA’s Center for Advanced Manufacturing where the thermal protection system will be applied.

  17. Ground-penetrating radar and electromagnetic surveys at the Monroe Crossroads battlefield site, Fort Bragg, North Carolina

    USGS Publications Warehouse

    Kessler, Richard; Strain, R.E.; Marlowe, J. I.; Currin, K.B.

    1996-01-01

    A ground-penetrating radar survey was conducted at the Monroe Crossroads Battlefield site at Fort Bragg, North Carolina, to determine possible locations of subsurface archaeological features. An electromagnetic survey also was conducted at the site to verify and augment the ground-penetrating radar data. The surveys were conducted over a 67,200-square-foot grid with a grid point spacing of 20 feet. During the ground-penetrating radar survey, 87 subsurface anomalies were detected based on visual inspection of the field records. These anomalies were flagged in the field as they appeared on the ground-penetrating radar records and were located by a land survey. The electromagnetic survey produced two significant readings at ground-penetrating radar anomaly locations. The National Park Service excavated 44 of the 87 anomaly locations at the Civil War battlefield site. Four of these excavations produced significant archaeological features, including one at an abandoned well.

  18. Vertical movement of ground water under the Merrill Field landfill, Anchorage, Alaska

    USGS Publications Warehouse

    Nelson, Gordon L.; Dearborn, L.L.

    1982-01-01

    Shallow groundwater under the Merrill Field sanitary landfill at Anchorage is polluted by leachate. Wells, including three Municipal-supply wells, obtain water from two confined aquifers 100-300 feet beneath the landfill area. Aquifer-test data and information on subsurface geology, ground-water levels, and properties of materials were used to estimate vertical gradients and vertical permeabilities under the landfill. The authors ' best estimates ' of vertical permeabilities of two confining units are 1 x 10 super -2 foot per day and 2 x 10 super -4 foot per day. Theoretical travel-time calculations indicate that minor amounts of pollutants may reach the upper confined aquifer after many tens of years, but that water of the composition of the leachate probably would not reach the aquifer for more than three centuries. The range of error in the theoretical travel-time calculations is likely to be plus or minus a factor of two or three. (USGS)

  19. STS-116 Astronauts Curbeam and Fuglesang Perform Space Walk

    NASA Technical Reports Server (NTRS)

    2006-01-01

    STS-116 astronaut and mission specialist, Robert Curbeam, along with the European Space Agency's (ESA) Christer Fuglesang (partially out of the frame), are anchored to the International Space Station's Canadarm2 foot restraints. The two were working on the port overhead solar array wing on the Station's P6 truss during the mission's fourth session of Extra Vehicular Activity (EVA). For 6 hours and 38 minutes, the space walkers used specially prepared, tape insulated tools to guide the array wing neatly inside its blanket box.

  20. International Space Station (ISS)

    NASA Image and Video Library

    2006-12-18

    STS-116 astronaut and mission specialist, Robert Curbeam, along with the European Space Agency’s (ESA) Christer Fuglesang (partially out of the frame), are anchored to the International Space Station’s Canadarm2 foot restraints. The two were working on the port overhead solar array wing on the Station’s P6 truss during the mission’s fourth session of Extra Vehicular Activity (EVA). For 6 hours and 38 minutes, the space walkers used specially prepared, tape insulated tools to guide the array wing neatly inside its blanket box.

  1. Design Criteria Upgrade for U.S. Army Type II Air Traffic Control Towers.

    DTIC Science & Technology

    1985-06-01

    additional layer of EPDM adhered to the roofing membrane at the perimeter should protect the roof from foot traffic. However, if heavy use or any...chance of abuse is anticipated, precast payers can be laid on an adhered EPDM pad. 49 SINGLE LAYER GYPSUM ROARD(TYP.) RIGID INSULATION(TYP.) -’ STEEL...stairwell is not air-conditioned, and its ventilation is poor. At the Fort Huachuca tower, the fan is isolated from the stairwell by the cab door, and

  2. Hydrology of the solid waste burial ground as related to potential migration of radionuclides, Idaho National Engineering Laboratory

    USGS Publications Warehouse

    Barraclough, Jack T.; Robertson, J.B.; Janzer, V.J.; Saindon, L.G.

    1976-01-01

    A study was made (1970-1974) to evaluate the geohydrologic and geochemical controls on subsurface migration of radionuclides from pits and trenches in the Idaho National Engineering Laboratory (INEL) solid waste burial ground and to determine the existence and extent of radionuclide migration from the burial ground. A total of about 1,700 sediment, rock, and water samples were collected from 10 observation wells drilled in and near the burial ground of Idaho National Engineering Laboratory, formerly the National Reactor Testing Station (NRTS). Within the burial ground area, the subsurface rocks are composed principally of basalt. Wind- and water-deposited sediments occur at the surface and in beds between the thicker basalt zones. Two principal sediment beds occur at about 110 feet and 240 feet below the land surface. The average thickness of the surficial sedimentary layer is about 15 feet while that of the two principal subsurface layers is 13 and 14 feet, respectively. The water table in the aquifer beneath the burial ground is at a depth of about 580 feet. Fission, activation, and transuranic elements were detected in some of the samples from the 110- and 240-foot sedimentary layers. (Woodard-USGS)

  3. Calibration method helps in seismic velocity interpretation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Guzman, C.E.; Davenport, H.A.; Wilhelm, R.

    1997-11-03

    Acoustic velocities derived from seismic reflection data, when properly calibrated to subsurface measurements, help interpreters make pure velocity predictions. A method of calibrating seismic to measured velocities has improved interpretation of subsurface features in the Gulf of Mexico. In this method, the interpreter in essence creates a kind of gauge. Properly calibrated, the gauge enables the interpreter to match predicted velocities to velocities measured at wells. Slow-velocity zones are of special interest because they sometimes appear near hydrocarbon accumulations. Changes in velocity vary in strength with location; the structural picture is hidden unless the variations are accounted for by mappingmore » in depth instead of time. Preliminary observations suggest that the presence of hydrocarbons alters the lithology in the neighborhood of the trap; this hydrocarbon effect may be reflected in the rock velocity. The effect indicates a direct use of seismic velocity in exploration. This article uses the terms seismic velocity and seismic stacking velocity interchangeably. It uses ground velocity, checkshot average velocity, and well velocity interchangeably. Interval velocities are derived from seismic stacking velocities or well average velocities; they refer to velocities of subsurface intervals or zones. Interval travel time (ITT) is the reciprocal of interval velocity in microseconds per foot.« less

  4. Soil nutrient concentration and distribution at riverbanks undergoing different land management practices: Implications for riverbank management

    NASA Astrophysics Data System (ADS)

    Xue, X. H.; Chang, S.; Yuan, L. Y.

    2017-08-01

    Riverbanks are important boundaries for the nutrient cycling between lands and freshwaters. This research aimed to explore effects of different land management methods on the soil nutrient concentration and distribution at riverbanks. Soils from the reed-covered riverbanks of middle Yangtze River were studied, including the soils respectively undergoing systematic agriculture (gathering young tender shoots, reaping reed straws, and burning residual straws), fires and no disturbances. Results showed that the agricultural activities sharply decreased the contents of soil organic matter (SOM), N, P and K in subsurface soils but less decreased the surface SOM, N and K contents, whereas phosphorus were evidently decreased at both surface and subsurface layers. In contrast, the single application of fires caused a marked increase of SOM, N, P and K contents in both surface and subsurface soils but had little impacts on soil nutrient distributions. Soils under all the three conditions showed a relative increase of soil nutrients at riverbank foot. This comparative study indicated that the different or even contrary effects of riverbank management practices on soil nutrient statuses should be carefully taken into account when assessing the ecological effects of management practices.

  5. Microbial DNA; a possible tracer of groundwater

    NASA Astrophysics Data System (ADS)

    Sugiyama, Ayumi; Segawa, Takuya; Furuta, Tsuyumi; Nagaosa, Kazuyo; Tsujimura, Maki; Kato, Kenji

    2017-04-01

    Though chemical analysis of groundwater shows an averaged value of chemistry of the examined water which was blended by various water with different sources and routes in subsurface environment, microbial DNA analysis may suggest the place where they originated, which may give information of the source and transport routes of the water examined. A huge amount of groundwater is stored in lava layer with maximum depth of 300m in Mt. Fuji (3,776m asl ), the largest volcanic mountain in Japan. Although the density of prokaryotes was low in the examined groundwater of Mt. Fuji, thermophilic prokaryotes as Thermoanaerobacterales, Gaiellales and Thermoplasmatales were significantly detected. They are optimally adapted to the temperature higher than 40oC. This finding suggests that at least some of the source of the examined groundwater was subsurface environment with 600m deep or greater, based on a temperature gradient of 4oC/100m and temperature of spring water ranges from 10 to 15oC in the foot of Mt. Fuji. This depth is far below the lava layer. Thus, the groundwater is not simply originated from the lava layer. In addition to those findings, we observed a very fast response of groundwater just a couple of weeks after the heavy rainfall exceeding 2 or 300 mm/event in Mt. Fuji. The fast response was suggested by a sharp increase in bacterial abundance in spring water located at 700m in height in the west foot of Mt. Fuji, where the average recharge elevation of groundwater was estimated to be 1,500m - 1,700m (Kato et. al. EGU 2016). This increase was mainly provided by soil bacteria as Burkholderiales, which might be detached from soil by strengthened subsurface flow caused by heavy rainfall. This suggests that heavy rainfall promotes shallow subsurface flow contributing to the discharge in addition to the groundwater in the deep aquifer. Microbial DNA, thus could give information about the route of the examined groundwater, which was never elucidated by analysis of chemical materials dissolved in groundwater. Though viral particle was employed as a tracer to chase the movement of groundwater, it doesn't tell the chemical and physical environmental condition where the particle was incorporated into groundwater. Thus, we propose microbial DNA as a new tracer to track the route of groundwater.

  6. Field-Deployable Reverse Transcription-Insulated Isothermal PCR (RT-iiPCR) Assay for Rapid and Sensitive Detection of Foot-and-Mouth Disease Virus.

    PubMed

    Ambagala, A; Fisher, M; Goolia, M; Nfon, C; Furukawa-Stoffer, T; Ortega Polo, R; Lung, O

    2017-10-01

    Foot-and-mouth disease (FMD) is a highly contagious viral disease of cloven-hoofed animals, which can decimate the livestock industry and economy of countries previously free of this disease. Rapid detection of foot-and-mouth disease virus (FMDV) is critical to containing an FMD outbreak. Availability of a rapid, highly sensitive and specific, yet simple and field-deployable assay would support local decision-making during an FMDV outbreak. Here we report validation of a novel reverse transcription-insulated isothermal PCR (RT-iiPCR) assay that can be performed on a commercially available, compact and portable POCKIT ™ analyser that automatically analyses data and displays '+' or '-' results. The FMDV RT-iiPCR assay targets the 3D region of the FMDV genome and was capable of detecting 9 copies of in vitro-transcribed RNA standard with 95% confidence. It accurately identified 63 FMDV strains belonging to all seven serotypes and showed no cross-reactivity with viruses causing similar clinical diseases in cloven-hoofed animals. The assay was able to identify FMDV RNA in multiple sample types including oral, nasal and lesion swabs, epithelial tissue suspensions, vesicular and oral fluid samples, even before the appearance of clinical signs. Clinical sensitivity of the assay was comparable or slightly higher than the laboratory-based real-time RT-PCR assay in use. The assay was able to detect FMDV RNA in vesicular fluid samples without nucleic acid extraction. For RNA extraction from more complex sample types, a commercially available taco ™ mini transportable magnetic bead-based, automated extraction system was used. This assay provides a potentially useful field-deployable diagnostic tool for rapid detection of FMDV in an outbreak in FMD-free countries or for routine diagnostics in endemic countries with less structured laboratory systems. © 2016 Her Majesty the Queen in Right of Canada.

  7. Investigation of space shuttle vehicle 140C configuration orbiter (model 16-0) wheel well pressure loads in the Rockwell International 7.75 x 11 foot wind tunnel (OA143)

    NASA Technical Reports Server (NTRS)

    Mennell, R. C.

    1975-01-01

    Experimental aerodynamic investigations were conducted on a sting mounted .0405-scale representation of the 140C outer mold line space shuttle orbiter configuration in the Rockwell International 7.75 x 11.00 foot low speed wind tunnel. The primary test objectives were to define the orbiter wheel well pressure loading and its effects on landing gear thermal insulation and to investigate the pressure environment experienced by both the horizontal flight nose probe and air vent door probes. Steady state and dynamic pressure values were recorded in the orbiter nose gear well, left main landing gear well, horizontal flight nose probe, and both left and right air vent door probe. All steady state pressure levels were measured by Statham differential pressure transducers while dynamic pressure levels were recorded by Kulite high frequency response pressure sensors.

  8. STS-103 crew pose at 195-foot level of Fixed Service Structure

    NASA Technical Reports Server (NTRS)

    1999-01-01

    At the 195-foot level of the Fixed Service Structure on Launch Pad 39B, the STS-103 crew take a break from Terminal Countdown Demonstration Test (TCDT) activities. Standing from left to right are Mission Specialists Jean-Frangois Clervoy of France and Claude Nicollier of Switzerland, who are with the European Space Agency; Commander Curtis L. Brown Jr.; Pilot Scott J. Kelly; and Mission Specialists John M. Grunsfeld (Ph.D.), C. Michael Foale (Ph.D.) and Steven L. Smith. The TCDT provides the crew with the emergency egress training, opportunities to inspect their mission payloads in the orbiter's payload bay, and simulated countdown exercises. STS-103 is a 'call-up' mission due to the need to replace and repair portions of the Hubble Space Telescope, including the gyroscopes that allow the telescope to point at stars, galaxies and planets. The STS-103 crew will be replacing a Fine Guidance Sensor, an older computer with a new enhanced model, an older data tape recorder with a solid-state digital recorder, a failed spare transmitter with a new one, and degraded insulation on the telescope with new thermal insulation. The crew will also install a Battery Voltage/Temperature Improvement Kit to protect the spacecraft batteries from overcharging and overheating when the telescope goes into a safe mode. Four EVA's are planned to make the necessary repairs and replacements on the telescope. The mission is targeted for launch Dec. 6 at 2:37 a.m. EST.

  9. Snake River Plain Geothermal Play Fairway Analysis - Phase 1 KMZ files

    DOE Data Explorer

    John Shervais

    2015-10-10

    This dataset contain raw data files in kmz files (Google Earth georeference format). These files include volcanic vent locations and age, the distribution of fine-grained lacustrine sediments (which act as both a seal and an insulating layer for hydrothermal fluids), and post-Miocene faults compiled from the Idaho Geological Survey, the USGS Quaternary Fault database, and unpublished mapping. It also contains the Composite Common Risk Segment Map created during Phase 1 studies, as well as a file with locations of select deep wells used to interrogate the subsurface.

  10. 8. Photographic copy of photograph, dated 1 October 1970 (original ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    8. Photographic copy of photograph, dated 1 October 1970 (original print in possession of CSSD-HO, Huntsville, AL). Morrison-Knudsen Company and Associates, photographer. View of 43-foot high midsection of Spartan launch tube and exhaust chamber as it was being prepared for sprint missile silo liners, prior to their installation within the subsurface holes at the missile launch site (June 1971). Note the silo liner at right; atop this is the launch preparation equipment chamber (LPEC) - Stanley R. Mickelsen Safeguard Complex, Missile Launch Area, Within Exclusion Area, Nekoma, Cavalier County, ND

  11. Surface Water Investigations in Afghanistan: A Summary of Activities from 1952 to 1969. Appendix 14: Hydrology Training Manual Number 1: Basic Streamaging

    DTIC Science & Technology

    1966-01-01

    insulated core is covered by 33 galvanized wires, of which the inner 15 are wrapped in one direction and the outer 18 are wrapped in the reverse...foot marks with Porcelain Enamel Iron Figure Plates. Figure 2•—Non-recording staff gages • Shelters should be well ventilated, especially in...vertical staff gage usually consists of porcelain -enameled iron sections. The sections are usually screwed to a board which is fastened to a suitable

  12. Muon radiography and deformation analysis of the lava dome formed by the 1944 eruption of Usu, Hokkaido —Contact between high-energy physics and volcano physics—

    PubMed Central

    TANAKA, Hiroyuki K. M.; YOKOYAMA, Izumi

    2008-01-01

    Lava domes are one of the conspicuous topographic features on volcanoes. The subsurface structure of the lava dome is important to discuss its formation mechanism. In the 1944 eruption of Volcano Usu, Hokkaido, a new lava dome was formed at its eastern foot. After the completion of the lava dome, various geophysical methods were applied to the dome to study its subsurface structure, but resulted in a rather ambiguous conclusion. Recently, from the results of the levelings, which were repeated during the eruption, “pseudo growth curves” of the lava dome were obtained. The curves suggest that the lava dome has a bulbous shape. In the present work, muon radiography, which previously proved effective in imaging the internal structure of Volcano Asama, has been applied to the Usu lava dome. The muon radiography measures the distribution of the “density length” of volcanic bodies when detectors are arranged properly. The result obtained is consistent with the model deduced from the pseudo growth curves. The measurement appears to afford useful method to clarify the subsurface structure of volcanoes and its temporal changes, and in its turn to discuss volcanic processes. This is a point of contact between high-energy physics and volcano physics. PMID:18941290

  13. Muon radiography and deformation analysis of the lava dome formed by the 1944 eruption of Usu, Hokkaido--contact between high-energy physics and volcano physics--.

    PubMed

    K M Tanaka, Hiroyuki; Yokoyama, Izumi

    2008-01-01

    Lava domes are one of the conspicuous topographic features on volcanoes. The subsurface structure of the lava dome is important to discuss its formation mechanism. In the 1944 eruption of Volcano Usu, Hokkaido, a new lava dome was formed at its eastern foot. After the completion of the lava dome, various geophysical methods were applied to the dome to study its subsurface structure, but resulted in a rather ambiguous conclusion. Recently, from the results of the levelings, which were repeated during the eruption, "pseudo growth curves" of the lava dome were obtained. The curves suggest that the lava dome has a bulbous shape. In the present work, muon radiography, which previously proved effective in imaging the internal structure of Volcano Asama, has been applied to the Usu lava dome. The muon radiography measures the distribution of the "density length" of volcanic bodies when detectors are arranged properly. The result obtained is consistent with the model deduced from the pseudo growth curves. The measurement appears to afford useful method to clarify the subsurface structure of volcanoes and its temporal changes, and in its turn to discuss volcanic processes. This is a point of contact between high-energy physics and volcano physics.

  14. Optical and electronic properties of sub-surface conducting layers in diamond created by MeV B-implantation at elevated temperatures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Willems van Beveren, L. H., E-mail: laurensw@unimelb.edu.au; Bowers, H.; Ganesan, K.

    2016-06-14

    Boron implantation with in-situ dynamic annealing is used to produce highly conductive sub-surface layers in type IIa (100) diamond plates for the search of a superconducting phase transition. Here, we demonstrate that high-fluence MeV ion-implantation, at elevated temperatures avoids graphitization and can be used to achieve doping densities of 6 at. %. In order to quantify the diamond crystal damage associated with implantation Raman spectroscopy was performed, demonstrating high temperature annealing recovers the lattice. Additionally, low-temperature electronic transport measurements show evidence of charge carrier densities close to the metal-insulator-transition. After electronic characterization, secondary ion mass spectrometry was performed to mapmore » out the ion profile of the implanted plates. The analysis shows close agreement with the simulated ion-profile assuming scaling factors that take into account an average change in diamond density due to device fabrication. Finally, the data show that boron diffusion is negligible during the high temperature annealing process.« less

  15. ELF-VLF communications through the Earth Project report for calendar year 1984, revision 1

    NASA Astrophysics Data System (ADS)

    Buettner, H. M.; Burker, G. J.; Didwall, E. M.; Holladay, G.; Lytle, R. J.

    1985-08-01

    We use computer models and experiments to explore the feasibility of communication between points underground and on the Earth's surface. Emphasis is placed on ELF-VLF electromagnetic propagation through the Earth; nominally, we investigated propagation in the 200 Hz-30 kHz frequency range. The computer modeling included calculations of the fields of a point electric or magnetic source in a homogeneous half space or a stratified earth. Initial results for an insulated antenna of finite length are also considered. The experiments involved through-the-Earth transmissions at two locations in Pennsylvania, both of which had large formations of limestone. Initial results indicate that information rates as high as kbits/s may be possible for subsurface depths of 300 m or less. Accuracy of these estimates depends on the electromagnetic propagation constant of the rock, the noise characteristics, and the modulation scheme. Although a nuisance for evaluating through-the-Earth propagation, the existence of subsurface metal conductors can improve the transmission character of the site.

  16. ELF-VLF communications through-the-Earth

    NASA Astrophysics Data System (ADS)

    Buettner, H. M.; Burke, G. J.; Didwall, E. M.; Holladay, G.; Lytle, R. J.

    1985-06-01

    We use computer models and experiments to explore the feasibility of communication between points underground and on the Earth's surface. Emphasis is placed on ELF-VLF electromagnetic propagation through the Earth; nominally, we investigated propagation in the 200 Hz-30 kHz frequency range. The computer modeling included calculations of the fields of a point electric or magnetic source in a homogeneous half space or a stratified Earth. Initial results for an insulated antenna of finite length are also considered. The experiments involved through-the-Earth transmissions at two locations in Pennsylvania, both of which had large formations of limestone. Initial results indicate that information rates as high as kbits/s may be possible for subsurface depths of 300 m or less. Accuracy of these estimates depends on the electromagnetic propagation constants of the rock, the noise characteristics, and modulation scheme. Although a nuisance for evaluating through-the-Earth propagation, the existence of subsurface metal conductors can improve the transmission character of the site.

  17. Low-cost sustainable wall construction system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vohra, A.; Rosenfeld, A.H.

    1998-07-01

    Houses with no wall cavities, such as those made of adobe, stone, brick, or block, have poor thermal properties but are rarely insulated because of the cost and difficulty of providing wall insulation. A simple, low-cost technique using loose-fill indigenous materials has been demonstrated for the construction of highly insulated walls or the retrofit of existing walls in such buildings. Locally available pumice, in sandbags stacked along the exterior wall of an adobe house in New Mexico, added a thermal resistance (R) of 16 F{sm{underscore}bullet}ft{sup 2}{sm{underscore}bullet}h/Btu (2.8 m{sup 2}{sm{underscore}bullet}K/W). The total cost of the sandbag insulation wall retrofit wasmore » $3.76 per square foot ($$40.50/m{sup 2}). Computer simulations of the adobe house using DOE 2.1E show savings of $$275 per year, corresponding to 50% reduction in heating energy consumption. The savings-to-investment ratio ranges from 1.1 to 3.2, so the cost of conserved energy is lower than the price of propane, natural gas and electric heat, making the system cost-effective. Prototype stand-alone walls were also constructed using fly ash and sawdust blown into continuous polypropylene tubing, which was folded between corner posts as it was filled to form the shape of the wall. Other materials could also be used. The inexpensive technique solves the problem of insulating solid-wall hours and constructing new houses without specialized equipment and skills, thereby saving energy, reducing greenhouse gas emissions, and improving comfort for people in many countries. The US Department of Energy (DOE) has filed patent applications on this technology, which is part of a DOE initiative on sustainable building envelope materials and systems.« less

  18. Prediction of hydrocarbon surface seepage potential using infiltrometer data

    NASA Astrophysics Data System (ADS)

    Connors, J. J.; Jackson, J. L.; Engle, R. A.; Connors, J. L.

    2017-12-01

    Environmental regulations addressing above-ground storage tank (AST) spill control activities typically require owners/operators to demonstrate that local soil permeability values are low enough to adequately contain released liquids while emergency-response procedures are conducted. Frequently, geotechnical borings and soil samples/analyses, and/or monitoring well slug-test analyses, are used to provide hydraulic conductivity data for the required calculations. While these techniques are useful in assessing hydrological characteristics of the subsurface, they do not always assess the uppermost surface soil layer, where the bulk of the containment can occur. This layer may have been subject to long-term permeability-reduction by activities such as compaction by vehicular and foot traffic, micro-coatings by hydrophobic pollutants, etc. This presentation explores the usefulness of dual-ring infiltrometers, both in field and bench-scale tests, to rapidly acquire actual hydraulic conductivity values of surficial soil layers, which can be much lower than subsurface values determined using more traditional downhole geotechnical and hydrogeological approaches.

  19. KSC-2009-6795

    NASA Image and Video Library

    2009-12-11

    CAPE CANAVERAL, Fla. - Concrete covers the insulation in the walls for the Propellants North Administrative and Maintenance Facility in Launch Complex 39 at NASA's Kennedy Space Center in Florida. A tilt-up construction method is being used to erect a THERMOMASS concrete wall insulation system for the facility's walls. In this approach, the exterior layer of concrete for the wall panels is poured and leveled on the building's footprint. Then, prefabricated, predrilled insulation sheets are arranged on top of the unhardened concrete, and connectors, designed to hold the sandwiched layers of concrete and insulation secure, are inserted through the predrilled holes. Next, the structural wythe is poured. Once cured, these panels are lifted upright to form the building's envelope. The facility will have a two-story administrative building to house managers, mechanics and technicians who fuel spacecraft at Kennedy adjacent to an 1,800-square-foot single-story shop to store cryogenic fuel transfer equipment. The new facility will feature high-efficiency roofs and walls, “Cool Dry Quiet” air conditioning with energy recovery technology, efficient lighting, and other sustainable features. The facility is striving to qualify for the U.S. Green Building Council’s Leadership in Energy and Environmental Design, or LEED, Platinum certification. If successful, Propellants North will be the first Kennedy facility to achieve this highest of LEED ratings after it is completed in the summer of 2010. The facility was designed for NASA by Jones Edmunds and Associates. Photo credit: NASA/Jim Grossmann

  20. KSC-2009-6801

    NASA Image and Video Library

    2009-12-11

    CAPE CANAVERAL, Fla. - In Launch Complex 39 at NASA's Kennedy Space Center in Florida, the walls for the Propellants North Administrative and Maintenance Facility get a layer of high-density foam insulation. A tilt-up construction method is being used to erect a THERMOMASS concrete wall insulation system for the facility's walls. In this approach, the exterior layer of concrete for the wall panels is poured and leveled on the building's footprint. Then, prefabricated, predrilled insulation sheets are arranged on top of the unhardened concrete, and connectors, designed to hold the sandwiched layers of concrete and insulation secure, are inserted through the predrilled holes. Next, the structural wythe is poured. Once cured, these panels are lifted upright to form the building's envelope. The facility will have a two-story administrative building to house managers, mechanics and technicians who fuel spacecraft at Kennedy adjacent to an 1,800-square-foot single-story shop to store cryogenic fuel transfer equipment. The new facility will feature high-efficiency roofs and walls, “Cool Dry Quiet” air conditioning with energy recovery technology, efficient lighting, and other sustainable features. The facility is striving to qualify for the U.S. Green Building Council’s Leadership in Energy and Environmental Design, or LEED, Platinum certification. If successful, Propellants North will be the first Kennedy facility to achieve this highest of LEED ratings after it is completed in the summer of 2010. The facility was designed for NASA by Jones Edmunds and Associates. Photo credit: NASA/Jim Grossmann

  1. KSC-2009-6800

    NASA Image and Video Library

    2009-12-11

    CAPE CANAVERAL, Fla. - Insulation is placed in the walls for the Propellants North Administrative and Maintenance Facility in Launch Complex 39 at NASA's Kennedy Space Center in Florida. A tilt-up construction method is being used to erect a THERMOMASS concrete wall insulation system for the facility's walls. In this approach, the exterior layer of concrete for the wall panels is poured and leveled on the building's footprint. Then, prefabricated, predrilled insulation sheets are arranged on top of the unhardened concrete, and connectors, designed to hold the sandwiched layers of concrete and insulation secure, are inserted through the predrilled holes. Next, the structural wythe is poured. Once cured, these panels are lifted upright to form the building's envelope. The facility will have a two-story administrative building to house managers, mechanics and technicians who fuel spacecraft at Kennedy adjacent to an 1,800-square-foot single-story shop to store cryogenic fuel transfer equipment. The new facility will feature high-efficiency roofs and walls, “Cool Dry Quiet” air conditioning with energy recovery technology, efficient lighting, and other sustainable features. The facility is striving to qualify for the U.S. Green Building Council’s Leadership in Energy and Environmental Design, or LEED, Platinum certification. If successful, Propellants North will be the first Kennedy facility to achieve this highest of LEED ratings after it is completed in the summer of 2010. The facility was designed for NASA by Jones Edmunds and Associates. Photo credit: NASA/Jim Grossmann

  2. KSC-2009-6793

    NASA Image and Video Library

    2009-12-11

    CAPE CANAVERAL, Fla. - Concrete is poured over the insulation in the walls for the Propellants North Administrative and Maintenance Facility in Launch Complex 39 at NASA's Kennedy Space Center in Florida. A tilt-up construction method is being used to erect a THERMOMASS concrete wall insulation system for the facility's walls. In this approach, the exterior layer of concrete for the wall panels is poured and leveled on the building's footprint. Then, prefabricated, predrilled insulation sheets are arranged on top of the unhardened concrete, and connectors, designed to hold the sandwiched layers of concrete and insulation secure, are inserted through the predrilled holes. Next, the structural wythe is poured. Once cured, these panels are lifted upright to form the building's envelope. The facility will have a two-story administrative building to house managers, mechanics and technicians who fuel spacecraft at Kennedy adjacent to an 1,800-square-foot single-story shop to store cryogenic fuel transfer equipment. The new facility will feature high-efficiency roofs and walls, “Cool Dry Quiet” air conditioning with energy recovery technology, efficient lighting, and other sustainable features. The facility is striving to qualify for the U.S. Green Building Council’s Leadership in Energy and Environmental Design, or LEED, Platinum certification. If successful, Propellants North will be the first Kennedy facility to achieve this highest of LEED ratings after it is completed in the summer of 2010. The facility was designed for NASA by Jones Edmunds and Associates. Photo credit: NASA/Jim Grossmann

  3. Site-level model intercomparison of high latitude and high altitude soil thermal dynamics in tundra and barren landscapes

    NASA Astrophysics Data System (ADS)

    Ekici, A.; Chadburn, S.; Chaudhary, N.; Hajdu, L. H.; Marmy, A.; Peng, S.; Boike, J.; Burke, E.; Friend, A. D.; Hauck, C.; Krinner, G.; Langer, M.; Miller, P. A.; Beer, C.

    2015-07-01

    Modeling soil thermal dynamics at high latitudes and altitudes requires representations of physical processes such as snow insulation, soil freezing and thawing and subsurface conditions like soil water/ice content and soil texture. We have compared six different land models: JSBACH, ORCHIDEE, JULES, COUP, HYBRID8 and LPJ-GUESS, at four different sites with distinct cold region landscape types, to identify the importance of physical processes in capturing observed temperature dynamics in soils. The sites include alpine, high Arctic, wet polygonal tundra and non-permafrost Arctic, thus showing how a range of models can represent distinct soil temperature regimes. For all sites, snow insulation is of major importance for estimating topsoil conditions. However, soil physics is essential for the subsoil temperature dynamics and thus the active layer thicknesses. This analysis shows that land models need more realistic surface processes, such as detailed snow dynamics and moss cover with changing thickness and wetness, along with better representations of subsoil thermal dynamics.

  4. The range of thermal insulation in the tissues of the new-born baby

    PubMed Central

    Hey, E. N.; Katz, G.

    1970-01-01

    1. Rectal temperature and skin temperatures were measured in twenty-eight naked babies weighing 1·1-4·5 kg, lying supine in environments of 25-31 °C when air speed was 4-7 cm/sec. The ratio of external insulation to internal or tissue insulation for the whole body averaged 2·7 but varied inversely with body weight; the ratio was higher than this on the trunk, and five times lower than this on the hand and foot. The mean ratio rose threefold when environmental temperature was increased to 34-35° C. 2. Direct measurements of heat flow from the back of a hand placed in a water jacket maintained at 32° C were made in thirty-three babies. Heat loss averaged 3 kcal/m2.hr.° C at low environmental temperature, but the loss was often rather less than this in the first 24 hr of life. Heat loss from the hand increased three- to fourfold, during exposure to an environment of 35° C. 3. When babies more than 48 hr old were exposed to an environment of 34-35° C, heat loss from the hand only increased when rectal temperature reached between 36·6 and 37·3° C; a slightly higher rectal temperature was usually reached before heat loss rose in babies less than 24 hr old. 4. Similar methods were used to study specific tissue insulation in three babies with congenital defects of the brain who lacked evidence of temperature control. No changes in insulation were detected in these three babies following changes in environmental temperature. 5. It is concluded that the range and pattern of control that can be exerted over the specific thermal insulation of the tissues is essentially the same in babies 2-20 days old as it is in adult life. PMID:5499741

  5. Scour at a bridge over the Weldon River, Iowa

    USGS Publications Warehouse

    Fischer, Edward E.; ,

    1993-01-01

    Contraction scour at the State Highway 2 bridge over the Weldon River in south-central Iowa was caused by a flood of record proportions on September 14 and 15, 1992. The peak discharge was 1, 930 cubic meters per second,which was 4 times the probable 100-year flood used to design the bridge, and resulted in road overflow. Contraction scour exposed the pier footings, but a subsurface layer of glacial clay apparently resisted additional vertical scour and caused the scouring process to move laterally. The embankment at the left abutment was eroded away, exposing 3 m of vertical abutment piling.

  6. Performance of LI-1542 reusable surface insulation system in a hypersonic stream

    NASA Technical Reports Server (NTRS)

    Hunt, L. R.; Bohon, H. L.

    1974-01-01

    The thermal and structural performance of a large panel of LI-1542 reusable surface insulation tiles was determined by a series of cyclic heating tests using radiant lamps and aerothemal tests in the Langley 8-foot high-temperature structures tunnel. Aerothermal tests were conducted at a free-stream Mach number of 6.6, a total temperature of 1830 K, Reynolds numbers of 2.0 and 4,900,000 per meter, and dynamic pressures of 29 and 65 kPa. The results suggest that pressure gradients in gaps and flow impingement on the header walls at the end of longitudinal gaps are sources for increased gap heating. Temperatures higher than surface radiation equilibrium temperature were measured deep in gaps and at the header walls. Also, the damage tolerance of the LI-1542 tiles appears to be very high. Tile edge erosion rate was slow; could not be tolerated in a shuttle application. Tiles soaked with water and subjected to rapid depressurization and aerodynamic heating showed no visible evidence of damage.

  7. Swanson prepares to retract the P6 Truss STBD SAW during EVA 2

    NASA Image and Video Library

    2007-06-13

    S117-E-07233 (13 June 2007) --- Astronauts Steven Swanson and Patrick Forrester (out of frame), both STS-117 mission specialists, participate in the mission's second planned session of extravehicular activity (EVA), as construction resumes on the International Space Station. Among other tasks, Forrester and Swanson removed all of the launch locks holding the 10-foot-wide solar alpha rotary joint in place and began the solar array retraction. Tethered to his Extravehicular Mobility Unit (EMU) spacesuit, a hockey-stick-shaped tool wrapped in insulating tape, is visible in front of Swanson.

  8. Swanson prepares to retract the P6 Truss STBD SAW during EVA 2

    NASA Image and Video Library

    2007-06-13

    S117-E-07234 (13 June 2007) --- Astronauts Steven Swanson and Patrick Forrester (out of frame), both STS-117 mission specialists, participate in the mission's second planned session of extravehicular activity (EVA), as construction resumes on the International Space Station. Among other tasks, Forrester and Swanson removed all of the launch locks holding the 10-foot-wide solar alpha rotary joint in place and began the solar array retraction. Tethered to his Extravehicular Mobility Unit (EMU) spacesuit, a hockey-stick-shaped tool wrapped in insulating tape, is visible in front of Swanson.

  9. BASIMO - Borehole Heat Exchanger Array Simulation and Optimization Tool

    NASA Astrophysics Data System (ADS)

    Schulte, Daniel O.; Bastian, Welsch; Wolfram, Rühaak; Kristian, Bär; Ingo, Sass

    2017-04-01

    Arrays of borehole heat exchangers are an increasingly popular source for renewable energy. Furthermore, they can serve as borehole thermal energy storage (BTES) systems for seasonally fluctuating heat sources like solar thermal energy or district heating grids. The high temperature level of these heat sources prohibits the use of the shallow subsurface for environmental reasons. Therefore, deeper reservoirs have to be accessed instead. The increased depth of the systems results in high investment costs and has hindered the implementation of this technology until now. Therefore, research of medium deep BTES systems relies on numerical simulation models. Current simulation tools cannot - or only to some extent - describe key features like partly insulated boreholes unless they run fully discretized models of the borehole heat exchangers. However, fully discretized models often come at a high computational cost, especially for large arrays of borehole heat exchangers. We give an update on the development of BASIMO: a tool, which uses one dimensional thermal resistance and capacity models for the borehole heat exchangers coupled with a numerical finite element model for the subsurface heat transport in a dual-continuum approach. An unstructured tetrahedral mesh bypasses the limitations of structured grids for borehole path geometries, while the thermal resistance and capacity model is improved to account for borehole heat exchanger properties changing with depth. Thereby, partly insulated boreholes can be considered in the model. Furthermore, BASIMO can be used to improve the design of BTES systems: the tool allows for automated parameter variations and is readily coupled to other code like mathematical optimization algorithms. Optimization can be used to determine the required minimum system size or to increase the system performance.

  10. KSC-2010-1158

    NASA Image and Video Library

    2010-01-08

    CAPE CANAVERAL, Fla. - In Launch Complex 39 at NASA's Kennedy Space Center in Florida, construction workers survey the last outside wall of the Propellants North Administrative and Maintenance Facility. Concrete layers on either side of high-density foam insulation in the facility's walls will prevent any transfer of radiant heat between the exterior and interior of the buildings. A tilt-up construction method is being used to erect a THERMOMASS concrete wall insulation system for the facility's walls. In this approach, the exterior layer of concrete for the wall panels is poured and leveled on the building's footprint. Then, prefabricated, predrilled insulation sheets are arranged on top of the unhardened concrete, and connectors, designed to hold the sandwiched layers of concrete and insulation secure, are inserted through the predrilled holes. Next, the structural wythe is poured. Once cured, these panels are lifted upright to form the building's envelope. The facility will have a two-story administrative building to house managers, mechanics and technicians who fuel spacecraft at Kennedy adjacent to an 1,800-square-foot single-story shop to store cryogenic fuel transfer equipment. The new facility will feature high-efficiency roofs and walls, “Cool Dry Quiet” air conditioning with energy recovery technology, efficient lighting, and other sustainable features. The facility is striving to qualify for the U.S. Green Building Council’s Leadership in Energy and Environmental Design, or LEED, Platinum certification. If successful, Propellants North will be the first Kennedy facility to achieve this highest of LEED ratings after it is completed in the summer of 2010. The facility was designed for NASA by Jones Edmunds and Associates. Photo credit: NASA/Jim Grossmann

  11. KSC-2009-6796

    NASA Image and Video Library

    2009-12-11

    CAPE CANAVERAL, Fla. - In Launch Complex 39 at NASA's Kennedy Space Center in Florida, concrete layers on either side of the high-density foam insulation of the Propellants North Administrative and Maintenance Facility's walls will prevent any transfer of radiant heat between the exterior and interior of the building. A tilt-up construction method is being used to erect a THERMOMASS concrete wall insulation system for the facility's walls. In this approach, the exterior layer of concrete for the wall panels is poured and leveled on the building's footprint. Then, prefabricated, predrilled insulation sheets are arranged on top of the unhardened concrete, and connectors, designed to hold the sandwiched layers of concrete and insulation secure, are inserted through the predrilled holes. Next, the structural wythe is poured. Once cured, these panels are lifted upright to form the building's envelope. The facility will have a two-story administrative building to house managers, mechanics and technicians who fuel spacecraft at Kennedy adjacent to an 1,800-square-foot single-story shop to store cryogenic fuel transfer equipment. The new facility will feature high-efficiency roofs and walls, “Cool Dry Quiet” air conditioning with energy recovery technology, efficient lighting, and other sustainable features. The facility is striving to qualify for the U.S. Green Building Council’s Leadership in Energy and Environmental Design, or LEED, Platinum certification. If successful, Propellants North will be the first Kennedy facility to achieve this highest of LEED ratings after it is completed in the summer of 2010. The facility was designed for NASA by Jones Edmunds and Associates. Photo credit: NASA/Jim Grossmann

  12. KSC-2009-6802

    NASA Image and Video Library

    2009-12-11

    CAPE CANAVERAL, Fla. - In Launch Complex 39 at NASA's Kennedy Space Center in Florida, high-density foam insulation between the concrete layers of the Propellants North Administrative and Maintenance Facility's walls will prevent any transfer of radiant heat between the exterior and interior of the building. A tilt-up construction method is being used to erect a THERMOMASS concrete wall insulation system for the facility's walls. In this approach, the exterior layer of concrete for the wall panels is poured and leveled on the building's footprint. Then, prefabricated, predrilled insulation sheets are arranged on top of the unhardened concrete, and connectors, designed to hold the sandwiched layers of concrete and insulation secure, are inserted through the predrilled holes. Next, the structural wythe is poured. Once cured, these panels are lifted upright to form the building's envelope. The facility will have a two-story administrative building to house managers, mechanics and technicians who fuel spacecraft at Kennedy adjacent to an 1,800-square-foot single-story shop to store cryogenic fuel transfer equipment. The new facility will feature high-efficiency roofs and walls, “Cool Dry Quiet” air conditioning with energy recovery technology, efficient lighting, and other sustainable features. The facility is striving to qualify for the U.S. Green Building Council’s Leadership in Energy and Environmental Design, or LEED, Platinum certification. If successful, Propellants North will be the first Kennedy facility to achieve this highest of LEED ratings after it is completed in the summer of 2010. The facility was designed for NASA by Jones Edmunds and Associates. Photo credit: NASA/Jim Grossmann

  13. Sulfate deposition in subsurface regolith in Gusev crater, Mars

    USGS Publications Warehouse

    Wang, A.; Haskin, L.A.; Squyres, S. W.; Jolliff, B.L.; Crumpler, L.; Gellert, Ralf; Schroder, C.; Herkenhoff, K.; Hurowitz, J.; Tosca, N.J.; Farrand, W. H.; Anderson, R.; Knudson, A.T.

    2006-01-01

    Excavating into the shallow Martian subsurface has the potential to expose stratigraphic layers and mature regolith, which may hold a record of more ancient aqueous interactions than those expected under current Martian surface conditions. During the Spirit rover's exploration of Gusev crater, rover wheels were used to dig three trenches into the subsurface regolith down to 6-11 cm depth: Road Cut, the Big Hole, and The Boroughs. A high oxidation state of Fe and high concentrations of Mg, S, Cl, and Br were found in the subsurface regolith within the two trenches on the plains, between the Bonneville crater and the foot of Columbia Hills. Data analyses on the basis of geochemistry and mineralogy observations suggest the deposition of sulfate minerals within the subsurface regolith, mainly Mg-sulfates accompanied by minor Ca-sulfates and perhaps Fe-sulfates. An increase of Fe2O3, an excess of SiO2, and a minor decrease in the olivine proportion relative to surface materials are also inferred. Three hypotheses are proposed to explain the geochemical trends observed in trenches: (1) multiple episodes of acidic fluid infiltration, accompanied by in situ interaction with igneous minerals and salt deposition; (2) an open hydrologic system characterized by ion transportation in the fluid, subsequent evaporation of the fluid, and salt deposition; and (3) emplacement and mixing of impact ejecta of variable composition. While all three may have plausibly contributed to the current state of the subsurface regolith, the geochemical data are most consistent with ion transportation by fluids and salt deposition as a result of open-system hydrologic behavior. Although sulfates make up >20 wt.% of the regolith in the wall of The Boroughs trench, a higher hydrated sulfate than kieserite within The Boroughs or a greater abundance of sulfates elsewhere than is seen in The Boroughs wall regolith would be needed to hold the structural water indicated by the water-equivalent hydrogen concentration observed by the Gamma-Ray Spectrometer on Odyssey in the Gusev region. Copyright 2006 by the American Geophysical Union.

  14. Quantification of the effect of temperature gradients in soils on subsurface radon signal

    NASA Astrophysics Data System (ADS)

    Haquin, Gustavo; Ilzycer, Danielle; Kamai, Tamir; Zafrir, Hovav; Weisbrod, Noam

    2017-04-01

    Temperature gradients that develop in soils due to atmospheric temperature cycles are factors of primary importance in determining the rates and directions of subsurface gas flow. Models including mechanisms of thermal convection and thermal diffusion partially explain the impact of temperature gradients on subsurface radon transport. However, the overall impact of temperature gradients on subsurface radon transport is still not well understood. A laboratory setup was designed and built to experimentally investigate the influence of temperature gradients on radon transport under well controlled conditions. A 60 cm diameter and 120 cm tall column was thermally insulated except from the atmosphere-soil interface, such that it was constructed to simulate field conditions where temperature gradients in soils are developed following atmospheric temperature cycles. The column was filled with fine grinded phosphate rock which provided the porous media with radon source. Radon in soil-air was continuously monitored using NaI gamma detectors positioned at different heights along the column. Soil temperature, differential pressure, and relative humidity were monitored along the column. Experiments based on steep and gradual stepwise changes in ambient temperature were conducted. Absolute changes on radon levels in the order of 10-30% were measured at temperature gradients of up to ±20oC/m. Results showed a non-linear correlation between the temperature gradient and the subsurface radon concentration. An asymmetric relationship between the radon concentration and the temperature gradients for ΔT>0 and ΔT<0 was also observed. Laboratory simulations of the time- and depth-dependent temperature wave functions with frequencies ranged from a daily cycle to few days were performed. In response to the harmonic temperature behaviour radon oscillations at similar frequencies were detected correspondingly. In this work a quantitative relationship between radon and temperature gradients will be presented for cases beyond the classical conditions for thermal convection and thermal diffusion.

  15. Terrestrial rock glaciers: a potential analog for Martian lobate flow features (LFF)

    NASA Astrophysics Data System (ADS)

    Sinha, Rishitosh K.; Vijayan, Sivaprahasam; Bharti, Rajiv R.

    2016-05-01

    Rock glaciers, regarded as cryospheric ice/water resource in the terrestrial-glacial systems based on their tongue/lobate-shaped flow characteristic and subsurface investigation using ground-penetrating radar. We examined the subsurface, geomorphology, climate-sensitivity and thermophysical properties of a Lobate Flow Feature (LFF) on Mars (30°-60° N and S hemispheres) to compare/assess the potentials of rock glaciers as an analog in suggesting LFFs to be a source of subsurface ice/water. LFFs are generally observed at the foot of impact craters' wall. HiRISE/CTX imageries from MRO spacecraft were used for geomorphological investigation of LFF using ArcMap-10.0 and subsurface investigation was carried out using data from MRO-SHARAD (shallow radar) after integrating with SiesWare-8.0. ENVI-5.0 was used to retrieve thermophysical properties of LFF from nighttime datasets (12.57 μm) acquired by THEMIS instrument-onboard the Mars Odyssey spacecraft and derive LFFs morphometry from MOLA altimeter point tracks onboard MGS spacecraft. Integrating crater chronology tool (Craterstats) with Arc Map, we have derived the formation age of LFF. Our investigation and comparison of LFF to rock glaciers revealed: (1) LFFs have preserved ice at depth 50m as revealed from SHARAD radargram and top-layer composed of rocky-debris material with thermal inertia ( 300-350 Jm-2 K-1s-1/2). (2) LFF formation age ( 10-100 Ma) corresponds to moderate scale debris covered glaciation of a shorter-span suggesting high sensitivity to obliquity-driven climatic shifts. (3) Presence of polygon cracks and high linear-arcuate furrow-and-ridges on the surface indicates presence of buried ice. This work is a significant step towards suggesting LFF to be a potential source of present-day stored ice/water on Mars.

  16. Results of the AFRSI detailed-environment test of the 0.035-scale SSV pressure-loads model 84-0 in the Ames 11x11 ft. TWT and the Lewis 8x6 ft. and 10x10 ft. SWT (OA-310A, B, C), volume 1

    NASA Technical Reports Server (NTRS)

    Marshall, B. A.; Marroquin, J.

    1984-01-01

    Detailed orbiter aerodynamic and aeroacoustic pressure data were obtained in a three-part experimental investigation (OA-310A, B and C). The tests were conducted in three NASA facilities: OA-310A in the Ames 11x11-foot Transonic Wind Tunnel; OA-310B in the Lewis 8x6-foot Supersonic Wind Tunnel; and OA-310C in the Lewis 10x10-foot Supersonic Wind Tunnel. Test data were obtained to support analysis of the Space Transportation System (STS)-6 advanced flexible reusable surface insulation (AFRSI) anomaly using the 0.035-scale space shuttle vehicle pressure-loads Model 84-0. Data were obtained in the areas of the orbiter where AFRSI is to be applied to OV-099 and OV-103. Emphasis was placed on acquiring detailed aeroacoustic data and time-averaged pressure distributions on five affected areas: (1) canopy; (2) side of fuselage; (3) upper surface of wing; (4) OMS pods; and (5) vertical tail. Data were obtained at nominal ascent and entry atmospheric flight trajectory conditions between M=0.6 through M-3.5. Sample plotted data are given. aba M.G.

  17. Cassidy during EVA-5

    NASA Image and Video Library

    2009-07-27

    S127-E-009322 (27 July 2009) --- Astronauts Tom Marshburn (left) and Christopher Cassidy, both STS-127 mission specialists, participate in the mission's fifth and final session of extravehicular activity (EVA) as construction and maintenance continue on the International Space Station. During the four-hour, 54-minute spacewalk, Marshburn and Cassidy secured multi-layer insulation around the Special Purpose Dexterous Manipulator known as Dextre, split out power channels for two space station Control Moment Gyroscopes, installed video cameras on the front and back of the new Japanese Exposed Facility and performed a number of “get ahead” tasks, including tying down some cables and installing handrails and a portable foot restraint to aid future spacewalkers.

  18. KSC-2010-1159

    NASA Image and Video Library

    2010-01-08

    CAPE CANAVERAL, Fla. - In Launch Complex 39 at NASA's Kennedy Space Center in Florida, with the placement of the last outside wall of the Propellants North Administrative and Maintenance Facility, the "barn-raising" of the new "green" facility is complete. Concrete layers on either side of high-density foam insulation in the facility's walls will prevent any transfer of radiant heat between the exterior and interior of the buildings. A tilt-up construction method is being used to erect a THERMOMASS concrete wall insulation system for the facility's walls. In this approach, the exterior layer of concrete for the wall panels is poured and leveled on the building's footprint. Then, prefabricated, predrilled insulation sheets are arranged on top of the unhardened concrete, and connectors, designed to hold the sandwiched layers of concrete and insulation secure, are inserted through the predrilled holes. Next, the structural wythe is poured. Once cured, these panels are lifted upright to form the building's envelope. The facility will have a two-story administrative building to house managers, mechanics and technicians who fuel spacecraft at Kennedy adjacent to an 1,800-square-foot single-story shop to store cryogenic fuel transfer equipment. The new facility will feature high-efficiency roofs and walls, “Cool Dry Quiet” air conditioning with energy recovery technology, efficient lighting, and other sustainable features. The facility is striving to qualify for the U.S. Green Building Council’s Leadership in Energy and Environmental Design, or LEED, Platinum certification. If successful, Propellants North will be the first Kennedy facility to achieve this highest of LEED ratings after it is completed in the summer of 2010. The facility was designed for NASA by Jones Edmunds and Associates. Photo credit: NASA/Jim Grossmann

  19. KSC-2010-1160

    NASA Image and Video Library

    2010-01-08

    CAPE CANAVERAL, Fla. - In Launch Complex 39 at NASA's Kennedy Space Center in Florida, this crane raised all of the outside walls of the Propellants North Administrative and Maintenance Facility over a period of two days. Concrete layers on either side of high-density foam insulation in the facility's walls will prevent any transfer of radiant heat between the exterior and interior of the buildings. A tilt-up construction method is being used to erect a THERMOMASS concrete wall insulation system for the facility's walls. In this approach, the exterior layer of concrete for the wall panels is poured and leveled on the building's footprint. Then, prefabricated, predrilled insulation sheets are arranged on top of the unhardened concrete, and connectors, designed to hold the sandwiched layers of concrete and insulation secure, are inserted through the predrilled holes. Next, the structural wythe is poured. Once cured, these panels are lifted upright to form the building's envelope. The facility will have a two-story administrative building to house managers, mechanics and technicians who fuel spacecraft at Kennedy adjacent to an 1,800-square-foot single-story shop to store cryogenic fuel transfer equipment. The new facility will feature high-efficiency roofs and walls, “Cool Dry Quiet” air conditioning with energy recovery technology, efficient lighting, and other sustainable features. The facility is striving to qualify for the U.S. Green Building Council’s Leadership in Energy and Environmental Design, or LEED, Platinum certification. If successful, Propellants North will be the first Kennedy facility to achieve this highest of LEED ratings after it is completed in the summer of 2010. The facility was designed for NASA by Jones Edmunds and Associates. Photo credit: NASA/Jim Grossmann

  20. KSC-2010-1157

    NASA Image and Video Library

    2010-01-08

    CAPE CANAVERAL, Fla. - In Launch Complex 39 at NASA's Kennedy Space Center in Florida, all of the exterior walls of the Propellants North Administrative and Maintenance Facility have been lifted into place. Concrete layers on either side of high-density foam insulation in the facility's walls will prevent any transfer of radiant heat between the exterior and interior of the buildings. A tilt-up construction method is being used to erect a THERMOMASS concrete wall insulation system for the facility's walls. In this approach, the exterior layer of concrete for the wall panels is poured and leveled on the building's footprint. Then, prefabricated, predrilled insulation sheets are arranged on top of the unhardened concrete, and connectors, designed to hold the sandwiched layers of concrete and insulation secure, are inserted through the predrilled holes. Next, the structural wythe is poured. Once cured, these panels are lifted upright to form the building's envelope. The facility will have a two-story administrative building to house managers, mechanics and technicians who fuel spacecraft at Kennedy adjacent to an 1,800-square-foot single-story shop to store cryogenic fuel transfer equipment. The new facility will feature high-efficiency roofs and walls, “Cool Dry Quiet” air conditioning with energy recovery technology, efficient lighting, and other sustainable features. The facility is striving to qualify for the U.S. Green Building Council’s Leadership in Energy and Environmental Design, or LEED, Platinum certification. If successful, Propellants North will be the first Kennedy facility to achieve this highest of LEED ratings after it is completed in the summer of 2010. The facility was designed for NASA by Jones Edmunds and Associates. Photo credit: NASA/Jim Grossmann

  1. KSC-2010-1161

    NASA Image and Video Library

    2010-01-08

    CAPE CANAVERAL, Fla. - In Launch Complex 39 at NASA's Kennedy Space Center in Florida, construction of the Propellants North Administrative and Maintenance Facility is moving ahead with the placement of all of the outside walls complete. Concrete layers on either side of high-density foam insulation in the facility's walls will prevent any transfer of radiant heat between the exterior and interior of the buildings. A tilt-up construction method is being used to erect a THERMOMASS concrete wall insulation system for the facility's walls. In this approach, the exterior layer of concrete for the wall panels is poured and leveled on the building's footprint. Then, prefabricated, predrilled insulation sheets are arranged on top of the unhardened concrete, and connectors, designed to hold the sandwiched layers of concrete and insulation secure, are inserted through the predrilled holes. Next, the structural wythe is poured. Once cured, these panels are lifted upright to form the building's envelope. The facility will have a two-story administrative building to house managers, mechanics and technicians who fuel spacecraft at Kennedy adjacent to an 1,800-square-foot single-story shop to store cryogenic fuel transfer equipment. The new facility will feature high-efficiency roofs and walls, “Cool Dry Quiet” air conditioning with energy recovery technology, efficient lighting, and other sustainable features. The facility is striving to qualify for the U.S. Green Building Council’s Leadership in Energy and Environmental Design, or LEED, Platinum certification. If successful, Propellants North will be the first Kennedy facility to achieve this highest of LEED ratings after it is completed in the summer of 2010. The facility was designed for NASA by Jones Edmunds and Associates. Photo credit: NASA/Jim Grossmann

  2. KSC-2010-1156

    NASA Image and Video Library

    2010-01-08

    CAPE CANAVERAL, Fla. - In Launch Complex 39 at NASA's Kennedy Space Center in Florida, the last outside wall of the Propellants North Administrative and Maintenance Facility is lifted into place. Concrete layers on either side of high-density foam insulation in the facility's walls will prevent any transfer of radiant heat between the exterior and interior of the buildings. A tilt-up construction method is being used to erect a THERMOMASS concrete wall insulation system for the facility's walls. In this approach, the exterior layer of concrete for the wall panels is poured and leveled on the building's footprint. Then, prefabricated, predrilled insulation sheets are arranged on top of the unhardened concrete, and connectors, designed to hold the sandwiched layers of concrete and insulation secure, are inserted through the predrilled holes. Next, the structural wythe is poured. Once cured, these panels are lifted upright to form the building's envelope. The facility will have a two-story administrative building to house managers, mechanics and technicians who fuel spacecraft at Kennedy adjacent to an 1,800-square-foot single-story shop to store cryogenic fuel transfer equipment. The new facility will feature high-efficiency roofs and walls, “Cool Dry Quiet” air conditioning with energy recovery technology, efficient lighting, and other sustainable features. The facility is striving to qualify for the U.S. Green Building Council’s Leadership in Energy and Environmental Design, or LEED, Platinum certification. If successful, Propellants North will be the first Kennedy facility to achieve this highest of LEED ratings after it is completed in the summer of 2010. The facility was designed for NASA by Jones Edmunds and Associates. Photo credit: NASA/Jim Grossmann

  3. Spin-orbit torque in a three-dimensional topological insulator-ferromagnet heterostructure: Crossover between bulk and surface transport

    NASA Astrophysics Data System (ADS)

    Ghosh, S.; Manchon, A.

    2018-04-01

    Current-driven spin-orbit torques are investigated in a heterostructure composed of a ferromagnet deposited on top of a three-dimensional topological insulator using the linear response formalism. We develop a tight-binding model of the heterostructure adopting a minimal interfacial hybridization scheme that promotes induced magnetic exchange on the topological surface states, as well as induced Rashba-like spin-orbit coupling in the ferromagnet. Therefore our model accounts for the spin Hall effect from bulk states together with inverse spin galvanic and magnetoelectric effects at the interface on equal footing. By varying the transport energy across the band structure, we uncover a crossover from surface-dominated to bulk-dominated transport regimes. We show that the spin density profile and the nature of the spin-orbit torques differ substantially in both regimes. Our results, which compare favorably with experimental observations, demonstrate that the large dampinglike torque reported recently is more likely attributed to the Berry curvature of interfacial states, while spin Hall torque remains small even in the bulk-dominated regime.

  4. Estimates of natural ground-water discharge and characterization of water quality in Dry Valley, Washoe County, West-Central Nevada, 2002-2003

    USGS Publications Warehouse

    Berger, David L.; Maurer, Douglas K.; Lopes, Thomas J.; Halford, Keith J.

    2004-01-01

    The Dry Valley Hydrographic Area is being considered as a potential source area for additional water supplies for the Reno-Sparks area, which is about 25 miles south of Dry Valley. Current estimates of annual ground-water recharge to Dry Valley have a considerable range. In undeveloped valleys, such as Dry Valley, long-term ground-water discharge can be assumed the same as long-term ground-water recharge. Because estimating ground-water discharge has more certainty than estimating ground-water recharge from precipitation, the U.S. Geological Survey, in cooperation with Washoe County, began a three-year study to re-evaluate the ground-water resources by estimating natural ground-water discharge and characterize ground-water quality in Dry Valley. In Dry Valley, natural ground-water discharge occurs as subsurface outflow and by ground-water evapotranspiration. The amount of subsurface outflow from the upper part of Dry Valley to Winnemucca and Honey Lake Valleys likely is small. Subsurface outflow from Dry Valley westward to Long Valley, California was estimated using Darcy's Law. Analysis of two aquifer tests show the transmissivity of poorly sorted sediments near the western side of Dry Valley is 1,200 to 1,500 square feet per day. The width of unconsolidated sediments is about 4,000 feet between exposures of tuffaceous deposits along the State line, and decreases to about 1,500 feet (0.5 mile) west of the State line. The hydraulic gradient east and west of the State line ranges from 0.003 to 0.005 foot per foot. Using these values, subsurface outflow to Long Valley is estimated to be 50 to 250 acre-feet per year. Areas of ground-water evapotranspiration were field mapped and partitioned into zones of plant cover using relations derived from Landsat imagery acquired July 8, 2002. Evapotranspiration rates for each plant-cover zone were multiplied by the corresponding area and summed to estimate annual ground-water evapotranspiration. About 640 to 790 acre-feet per year of ground water is lost to evapotranspiration in Dry Valley. Combining subsurface-outflow estimates with ground-water evapotranspiration estimates, total natural ground-water discharge from Dry Valley ranges from a minimum of about 700 acre-feet to a maximum of about 1,000 acre-feet annually. Water quality in Dry Valley generally is good and primary drinking-water standards were not exceeded in any samples collected. The secondary standard for manganese was exceeded in three ground-water samples. One spring sample and two surface-water samples exceeded the secondary standard for pH. Dry Valley has two primary types of water chemistry that are distinguishable by cation ratios and related to the two volcanic-rock units that make up much of the surrounding mountains. In addition, two secondary types of water chemistry appear to have evolved by evaporation of the primary water types. Ground water near the State line appears to be an equal mixture of the two primary water chemistries and has as an isotopic characteristic similar to evaporated surface water.

  5. The Impact of Detailed Snow Physics on the Simulation of Snow Cover and Subsurface Thermodynamics at Continental Scales

    NASA Technical Reports Server (NTRS)

    Stieglitz, Marc; Ducharne, Agnes; Koster, Randy; Suarez, Max; Busalacchi, Antonio J. (Technical Monitor)

    2000-01-01

    The three-layer snow model is coupled to the global catchment-based Land Surface Model (LSM) of the NASA Seasonal to Interannual Prediction Project (NSIPP) project, and the combined models are used to simulate the growth and ablation of snow cover over the North American continent for the period 1987-1988. The various snow processes included in the three-layer model, such as snow melting and re-freezing, dynamic changes in snow density, and snow insulating properties, are shown (through a comparison with the corresponding simulation using a much simpler snow model) to lead to an improved simulation of ground thermodynamics on the continental scale.

  6. KSC-2010-1110

    NASA Image and Video Library

    2010-01-07

    CAPE CANAVERAL, Fla. - In Launch Complex 39 at NASA's Kennedy Space Center in Florida, one of the walls of the Propellants North Administrative and Maintenance Facility is lowered into the trench which will support it. A tilt-up construction method is being used to erect a THERMOMASS concrete wall insulation system for the facility's walls. In this approach, the exterior layer of concrete for the wall panels is poured and leveled on the building's footprint. Then, prefabricated, predrilled insulation sheets are arranged on top of the unhardened concrete, and connectors, designed to hold the sandwiched layers of concrete and insulation secure, are inserted through the predrilled holes. Next, the structural wythe is poured. Once cured, these panels are lifted upright to form the building's envelope. The facility will have a two-story administrative building to house managers, mechanics and technicians who fuel spacecraft at Kennedy adjacent to an 1,800-square-foot single-story shop to store cryogenic fuel transfer equipment. The new facility will feature high-efficiency roofs and walls, “Cool Dry Quiet” air conditioning with energy recovery technology, efficient lighting, and other sustainable features. The facility is striving to qualify for the U.S. Green Building Council’s Leadership in Energy and Environmental Design, or LEED, Platinum certification. If successful, Propellants North will be the first Kennedy facility to achieve this highest of LEED ratings after it is completed in the summer of 2010. The facility was designed for NASA by Jones Edmunds and Associates. Photo credit: NASA/Jim Grossmann

  7. KSC-2009-6799

    NASA Image and Video Library

    2009-12-11

    CAPE CANAVERAL, Fla. - Construction of the walls for the Propellants North Administrative and Maintenance Facility begins in Launch Complex 39 at NASA's Kennedy Space Center in Florida. A tilt-up construction method is being used to erect a THERMOMASS concrete wall insulation system for the facility's walls. In this approach, the exterior layer of concrete for the wall panels is poured and leveled on the building's footprint. Then, prefabricated, predrilled insulation sheets are arranged on top of the unhardened concrete, and connectors, designed to hold the sandwiched layers of concrete and insulation secure, are inserted through the predrilled holes. Next, the structural wythe is poured. Once cured, these panels are lifted upright to form the building's envelope. The facility will have a two-story administrative building to house managers, mechanics and technicians who fuel spacecraft at Kennedy adjacent to an 1,800-square-foot single-story shop to store cryogenic fuel transfer equipment. The new facility will feature high-efficiency roofs and walls, “Cool Dry Quiet” air conditioning with energy recovery technology, efficient lighting, and other sustainable features. The facility is striving to qualify for the U.S. Green Building Council’s Leadership in Energy and Environmental Design, or LEED, Platinum certification. If successful, Propellants North will be the first Kennedy facility to achieve this highest of LEED ratings after it is completed in the summer of 2010. The facility was designed for NASA by Jones Edmunds and Associates. Photo credit: NASA/Jim Grossmann

  8. KSC-2010-1109

    NASA Image and Video Library

    2010-01-07

    CAPE CANAVERAL, Fla. - In Launch Complex 39 at NASA's Kennedy Space Center in Florida, workers guide one of the walls of the Propellants North Administrative and Maintenance Facility into place. A tilt-up construction method is being used to erect a THERMOMASS concrete wall insulation system for the facility's walls. In this approach, the exterior layer of concrete for the wall panels is poured and leveled on the building's footprint. Then, prefabricated, predrilled insulation sheets are arranged on top of the unhardened concrete, and connectors, designed to hold the sandwiched layers of concrete and insulation secure, are inserted through the predrilled holes. Next, the structural wythe is poured. Once cured, these panels are lifted upright to form the building's envelope. The facility will have a two-story administrative building to house managers, mechanics and technicians who fuel spacecraft at Kennedy adjacent to an 1,800-square-foot single-story shop to store cryogenic fuel transfer equipment. The new facility will feature high-efficiency roofs and walls, “Cool Dry Quiet” air conditioning with energy recovery technology, efficient lighting, and other sustainable features. The facility is striving to qualify for the U.S. Green Building Council’s Leadership in Energy and Environmental Design, or LEED, Platinum certification. If successful, Propellants North will be the first Kennedy facility to achieve this highest of LEED ratings after it is completed in the summer of 2010. The facility was designed for NASA by Jones Edmunds and Associates. Photo credit: NASA/Jim Grossmann

  9. KSC-2010-1120

    NASA Image and Video Library

    2010-01-07

    CAPE CANAVERAL, Fla. - In Launch Complex 39 at NASA's Kennedy Space Center in Florida, the final shape of the Propellants North Administrative and Maintenance Facility becomes apparent as its walls are erected. A tilt-up construction method is being used to erect a THERMOMASS concrete wall insulation system for the facility's walls. In this approach, the exterior layer of concrete for the wall panels is poured and leveled on the building's footprint. Then, prefabricated, predrilled insulation sheets are arranged on top of the unhardened concrete, and connectors, designed to hold the sandwiched layers of concrete and insulation secure, are inserted through the predrilled holes. Next, the structural wythe is poured. Once cured, these panels are lifted upright to form the building's envelope. The facility will have a two-story administrative building to house managers, mechanics and technicians who fuel spacecraft at Kennedy adjacent to an 1,800-square-foot single-story shop to store cryogenic fuel transfer equipment. The new facility will feature high-efficiency roofs and walls, “Cool Dry Quiet” air conditioning with energy recovery technology, efficient lighting, and other sustainable features. The facility is striving to qualify for the U.S. Green Building Council’s Leadership in Energy and Environmental Design, or LEED, Platinum certification. If successful, Propellants North will be the first Kennedy facility to achieve this highest of LEED ratings after it is completed in the summer of 2010. The facility was designed for NASA by Jones Edmunds and Associates. Photo credit: NASA/Jim Grossmann

  10. KSC-2010-1117

    NASA Image and Video Library

    2010-01-07

    CAPE CANAVERAL, Fla. - In Launch Complex 39 at NASA's Kennedy Space Center in Florida, a team of construction workers ensures that the walls of the Propellants North Administrative and Maintenance Facility are installed properly. A tilt-up construction method is being used to erect a THERMOMASS concrete wall insulation system for the facility's walls. In this approach, the exterior layer of concrete for the wall panels is poured and leveled on the building's footprint. Then, prefabricated, predrilled insulation sheets are arranged on top of the unhardened concrete, and connectors, designed to hold the sandwiched layers of concrete and insulation secure, are inserted through the predrilled holes. Next, the structural wythe is poured. Once cured, these panels are lifted upright to form the building's envelope. The facility will have a two-story administrative building to house managers, mechanics and technicians who fuel spacecraft at Kennedy adjacent to an 1,800-square-foot single-story shop to store cryogenic fuel transfer equipment. The new facility will feature high-efficiency roofs and walls, “Cool Dry Quiet” air conditioning with energy recovery technology, efficient lighting, and other sustainable features. The facility is striving to qualify for the U.S. Green Building Council’s Leadership in Energy and Environmental Design, or LEED, Platinum certification. If successful, Propellants North will be the first Kennedy facility to achieve this highest of LEED ratings after it is completed in the summer of 2010. The facility was designed for NASA by Jones Edmunds and Associates. Photo credit: NASA/Jim Grossmann

  11. KSC-2010-1115

    NASA Image and Video Library

    2010-01-07

    CAPE CANAVERAL, Fla. - In Launch Complex 39 at NASA's Kennedy Space Center in Florida, a crane is enlisted to lift the walls of the Propellants North Administrative and Maintenance Facility into position. A tilt-up construction method is being used to erect a THERMOMASS concrete wall insulation system for the facility's walls. In this approach, the exterior layer of concrete for the wall panels is poured and leveled on the building's footprint. Then, prefabricated, predrilled insulation sheets are arranged on top of the unhardened concrete, and connectors, designed to hold the sandwiched layers of concrete and insulation secure, are inserted through the predrilled holes. Next, the structural wythe is poured. Once cured, these panels are lifted upright to form the building's envelope. The facility will have a two-story administrative building to house managers, mechanics and technicians who fuel spacecraft at Kennedy adjacent to an 1,800-square-foot single-story shop to store cryogenic fuel transfer equipment. The new facility will feature high-efficiency roofs and walls, “Cool Dry Quiet” air conditioning with energy recovery technology, efficient lighting, and other sustainable features. The facility is striving to qualify for the U.S. Green Building Council’s Leadership in Energy and Environmental Design, or LEED, Platinum certification. If successful, Propellants North will be the first Kennedy facility to achieve this highest of LEED ratings after it is completed in the summer of 2010. The facility was designed for NASA by Jones Edmunds and Associates. Photo credit: NASA/Jim Grossmann

  12. KSC-2010-1112

    NASA Image and Video Library

    2010-01-07

    CAPE CANAVERAL, Fla. - In Launch Complex 39 at NASA's Kennedy Space Center in Florida, the Propellants North Administrative and Maintenance Facility begins to take shape as its walls are lifted into position. A tilt-up construction method is being used to erect a THERMOMASS concrete wall insulation system for the facility's walls. In this approach, the exterior layer of concrete for the wall panels is poured and leveled on the building's footprint. Then, prefabricated, predrilled insulation sheets are arranged on top of the unhardened concrete, and connectors, designed to hold the sandwiched layers of concrete and insulation secure, are inserted through the predrilled holes. Next, the structural wythe is poured. Once cured, these panels are lifted upright to form the building's envelope. The facility will have a two-story administrative building to house managers, mechanics and technicians who fuel spacecraft at Kennedy adjacent to an 1,800-square-foot single-story shop to store cryogenic fuel transfer equipment. The new facility will feature high-efficiency roofs and walls, “Cool Dry Quiet” air conditioning with energy recovery technology, efficient lighting, and other sustainable features. The facility is striving to qualify for the U.S. Green Building Council’s Leadership in Energy and Environmental Design, or LEED, Platinum certification. If successful, Propellants North will be the first Kennedy facility to achieve this highest of LEED ratings after it is completed in the summer of 2010. The facility was designed for NASA by Jones Edmunds and Associates. Photo credit: NASA/Jim Grossmann

  13. KSC-2010-1111

    NASA Image and Video Library

    2010-01-07

    CAPE CANAVERAL, Fla. - In Launch Complex 39 at NASA's Kennedy Space Center in Florida, the Propellants North Administrative and Maintenance Facility begins to take shape as its walls are lifted into position. A tilt-up construction method is being used to erect a THERMOMASS concrete wall insulation system for the facility's walls. In this approach, the exterior layer of concrete for the wall panels is poured and leveled on the building's footprint. Then, prefabricated, predrilled insulation sheets are arranged on top of the unhardened concrete, and connectors, designed to hold the sandwiched layers of concrete and insulation secure, are inserted through the predrilled holes. Next, the structural wythe is poured. Once cured, these panels are lifted upright to form the building's envelope. The facility will have a two-story administrative building to house managers, mechanics and technicians who fuel spacecraft at Kennedy adjacent to an 1,800-square-foot single-story shop to store cryogenic fuel transfer equipment. The new facility will feature high-efficiency roofs and walls, “Cool Dry Quiet” air conditioning with energy recovery technology, efficient lighting, and other sustainable features. The facility is striving to qualify for the U.S. Green Building Council’s Leadership in Energy and Environmental Design, or LEED, Platinum certification. If successful, Propellants North will be the first Kennedy facility to achieve this highest of LEED ratings after it is completed in the summer of 2010. The facility was designed for NASA by Jones Edmunds and Associates. Photo credit: NASA/Jim Grossmann

  14. KSC-2010-1108

    NASA Image and Video Library

    2010-01-07

    CAPE CANAVERAL, Fla. - In Launch Complex 39 at NASA's Kennedy Space Center in Florida, one of the walls of the Propellants North Administrative and Maintenance Facility glides through the air into position. A tilt-up construction method is being used to erect a THERMOMASS concrete wall insulation system for the facility's walls. In this approach, the exterior layer of concrete for the wall panels is poured and leveled on the building's footprint. Then, prefabricated, predrilled insulation sheets are arranged on top of the unhardened concrete, and connectors, designed to hold the sandwiched layers of concrete and insulation secure, are inserted through the predrilled holes. Next, the structural wythe is poured. Once cured, these panels are lifted upright to form the building's envelope. The facility will have a two-story administrative building to house managers, mechanics and technicians who fuel spacecraft at Kennedy adjacent to an 1,800-square-foot single-story shop to store cryogenic fuel transfer equipment. The new facility will feature high-efficiency roofs and walls, “Cool Dry Quiet” air conditioning with energy recovery technology, efficient lighting, and other sustainable features. The facility is striving to qualify for the U.S. Green Building Council’s Leadership in Energy and Environmental Design, or LEED, Platinum certification. If successful, Propellants North will be the first Kennedy facility to achieve this highest of LEED ratings after it is completed in the summer of 2010. The facility was designed for NASA by Jones Edmunds and Associates. Photo credit: NASA/Jim Grossmann

  15. KSC-2010-1118

    NASA Image and Video Library

    2010-01-07

    CAPE CANAVERAL, Fla. - In Launch Complex 39 at NASA's Kennedy Space Center in Florida, a row of walls is erected as the Propellants North Administrative and Maintenance Facility takes shape. A tilt-up construction method is being used to erect a THERMOMASS concrete wall insulation system for the facility's walls. In this approach, the exterior layer of concrete for the wall panels is poured and leveled on the building's footprint. Then, prefabricated, predrilled insulation sheets are arranged on top of the unhardened concrete, and connectors, designed to hold the sandwiched layers of concrete and insulation secure, are inserted through the predrilled holes. Next, the structural wythe is poured. Once cured, these panels are lifted upright to form the building's envelope. The facility will have a two-story administrative building to house managers, mechanics and technicians who fuel spacecraft at Kennedy adjacent to an 1,800-square-foot single-story shop to store cryogenic fuel transfer equipment. The new facility will feature high-efficiency roofs and walls, “Cool Dry Quiet” air conditioning with energy recovery technology, efficient lighting, and other sustainable features. The facility is striving to qualify for the U.S. Green Building Council’s Leadership in Energy and Environmental Design, or LEED, Platinum certification. If successful, Propellants North will be the first Kennedy facility to achieve this highest of LEED ratings after it is completed in the summer of 2010. The facility was designed for NASA by Jones Edmunds and Associates. Photo credit: NASA/Jim Grossmann

  16. KSC-2010-1121

    NASA Image and Video Library

    2010-01-07

    CAPE CANAVERAL, Fla. - In Launch Complex 39 at NASA's Kennedy Space Center in Florida, reminiscent of a barn-raising, the Propellants North Administrative and Maintenance Facility springs into being in a single day as its walls are lifted into position. A tilt-up construction method is being used to erect a THERMOMASS concrete wall insulation system for the facility's walls. In this approach, the exterior layer of concrete for the wall panels is poured and leveled on the building's footprint. Then, prefabricated, predrilled insulation sheets are arranged on top of the unhardened concrete, and connectors, designed to hold the sandwiched layers of concrete and insulation secure, are inserted through the predrilled holes. Next, the structural wythe is poured. Once cured, these panels are lifted upright to form the building's envelope. The facility will have a two-story administrative building to house managers, mechanics and technicians who fuel spacecraft at Kennedy adjacent to an 1,800-square-foot single-story shop to store cryogenic fuel transfer equipment. The new facility will feature high-efficiency roofs and walls, “Cool Dry Quiet” air conditioning with energy recovery technology, efficient lighting, and other sustainable features. The facility is striving to qualify for the U.S. Green Building Council’s Leadership in Energy and Environmental Design, or LEED, Platinum certification. If successful, Propellants North will be the first Kennedy facility to achieve this highest of LEED ratings after it is completed in the summer of 2010. The facility was designed for NASA by Jones Edmunds and Associates. Photo credit: NASA/Jim Grossmann

  17. KSC-2010-1119

    NASA Image and Video Library

    2010-01-07

    CAPE CANAVERAL, Fla. - In Launch Complex 39 at NASA's Kennedy Space Center in Florida, steady progress is made by a team of construction workers to erect the walls of the Propellants North Administrative and Maintenance Facility. A tilt-up construction method is being used to erect a THERMOMASS concrete wall insulation system for the facility's walls. In this approach, the exterior layer of concrete for the wall panels is poured and leveled on the building's footprint. Then, prefabricated, predrilled insulation sheets are arranged on top of the unhardened concrete, and connectors, designed to hold the sandwiched layers of concrete and insulation secure, are inserted through the predrilled holes. Next, the structural wythe is poured. Once cured, these panels are lifted upright to form the building's envelope. The facility will have a two-story administrative building to house managers, mechanics and technicians who fuel spacecraft at Kennedy adjacent to an 1,800-square-foot single-story shop to store cryogenic fuel transfer equipment. The new facility will feature high-efficiency roofs and walls, “Cool Dry Quiet” air conditioning with energy recovery technology, efficient lighting, and other sustainable features. The facility is striving to qualify for the U.S. Green Building Council’s Leadership in Energy and Environmental Design, or LEED, Platinum certification. If successful, Propellants North will be the first Kennedy facility to achieve this highest of LEED ratings after it is completed in the summer of 2010. The facility was designed for NASA by Jones Edmunds and Associates. Photo credit: NASA/Jim Grossmann

  18. KSC-2010-1107

    NASA Image and Video Library

    2010-01-07

    CAPE CANAVERAL, Fla. - In Launch Complex 39 at NASA's Kennedy Space Center in Florida, workers lift one of the walls of the Propellants North Administrative and Maintenance Facility into an upright position. A tilt-up construction method is being used to erect a THERMOMASS concrete wall insulation system for the facility's walls. In this approach, the exterior layer of concrete for the wall panels is poured and leveled on the building's footprint. Then, prefabricated, predrilled insulation sheets are arranged on top of the unhardened concrete, and connectors, designed to hold the sandwiched layers of concrete and insulation secure, are inserted through the predrilled holes. Next, the structural wythe is poured. Once cured, these panels are lifted upright to form the building's envelope. The facility will have a two-story administrative building to house managers, mechanics and technicians who fuel spacecraft at Kennedy adjacent to an 1,800-square-foot single-story shop to store cryogenic fuel transfer equipment. The new facility will feature high-efficiency roofs and walls, “Cool Dry Quiet” air conditioning with energy recovery technology, efficient lighting, and other sustainable features. The facility is striving to qualify for the U.S. Green Building Council’s Leadership in Energy and Environmental Design, or LEED, Platinum certification. If successful, Propellants North will be the first Kennedy facility to achieve this highest of LEED ratings after it is completed in the summer of 2010. The facility was designed for NASA by Jones Edmunds and Associates. Photo credit: NASA/Jim Grossmann

  19. KSC-2010-1116

    NASA Image and Video Library

    2010-01-07

    CAPE CANAVERAL, Fla. - In Launch Complex 39 at NASA's Kennedy Space Center in Florida, man and machine work side by side to position the walls of the Propellants North Administrative and Maintenance Facility. A tilt-up construction method is being used to erect a THERMOMASS concrete wall insulation system for the facility's walls. In this approach, the exterior layer of concrete for the wall panels is poured and leveled on the building's footprint. Then, prefabricated, predrilled insulation sheets are arranged on top of the unhardened concrete, and connectors, designed to hold the sandwiched layers of concrete and insulation secure, are inserted through the predrilled holes. Next, the structural wythe is poured. Once cured, these panels are lifted upright to form the building's envelope. The facility will have a two-story administrative building to house managers, mechanics and technicians who fuel spacecraft at Kennedy adjacent to an 1,800-square-foot single-story shop to store cryogenic fuel transfer equipment. The new facility will feature high-efficiency roofs and walls, “Cool Dry Quiet” air conditioning with energy recovery technology, efficient lighting, and other sustainable features. The facility is striving to qualify for the U.S. Green Building Council’s Leadership in Energy and Environmental Design, or LEED, Platinum certification. If successful, Propellants North will be the first Kennedy facility to achieve this highest of LEED ratings after it is completed in the summer of 2010. The facility was designed for NASA by Jones Edmunds and Associates. Photo credit: NASA/Jim Grossmann

  20. KSC-2010-1113

    NASA Image and Video Library

    2010-01-07

    CAPE CANAVERAL, Fla. - In Launch Complex 39 at NASA's Kennedy Space Center in Florida, a worker is seen through an opening left for a doorway in a newly erected wall of the Propellants North Administrative and Maintenance Facility. A tilt-up construction method is being used to erect a THERMOMASS concrete wall insulation system for the facility's walls. In this approach, the exterior layer of concrete for the wall panels is poured and leveled on the building's footprint. Then, prefabricated, predrilled insulation sheets are arranged on top of the unhardened concrete, and connectors, designed to hold the sandwiched layers of concrete and insulation secure, are inserted through the predrilled holes. Next, the structural wythe is poured. Once cured, these panels are lifted upright to form the building's envelope. The facility will have a two-story administrative building to house managers, mechanics and technicians who fuel spacecraft at Kennedy adjacent to an 1,800-square-foot single-story shop to store cryogenic fuel transfer equipment. The new facility will feature high-efficiency roofs and walls, “Cool Dry Quiet” air conditioning with energy recovery technology, efficient lighting, and other sustainable features. The facility is striving to qualify for the U.S. Green Building Council’s Leadership in Energy and Environmental Design, or LEED, Platinum certification. If successful, Propellants North will be the first Kennedy facility to achieve this highest of LEED ratings after it is completed in the summer of 2010. The facility was designed for NASA by Jones Edmunds and Associates. Photo credit: NASA/Jim Grossmann

  1. Spatially-protected Topology and Group Cohomology in Band Insulators

    NASA Astrophysics Data System (ADS)

    Alexandradinata, A.

    This thesis investigates band topologies which rely fundamentally on spatial symmetries. A basic geometric property that distinguishes spatial symmetry regards their transformation of the spatial origin. Point groups consist of spatial transformations that preserve the spatial origin, while un-split extensions of the point groups by spatial translations are referred to as nonsymmorphic space groups. The first part of the thesis addresses topological phases with discretely-robust surface properties: we introduce theories for the Cnv point groups, as well as certain nonsymmorphic groups that involve glide reflections. These band insulators admit a powerful characterization through the geometry of quasimomentum space; parallel transport in this space is represented by the Wilson loop. The non-symmorphic topology we study is naturally described by a further extension of the nonsymmorphic space group by quasimomentum translations (the Wilson loop), thus placing real and quasimomentum space on equal footing -- here, we introduce the language of group cohomology into the theory of band insulators. The second part of the thesis addresses topological phases without surface properties -- their only known physical consequences are discrete signatures in parallel transport. We provide two such case studies with spatial-inversion and discrete-rotational symmetries respectively. One lesson learned here regards the choice of parameter loops in which we carry out transport -- the loop must be chosen to exploit the symmetry that protects the topology. While straight loops are popular for their connection with the geometric theory of polarization, we show that bent loops also have utility in topological band theory.

  2. Respiratory interactions of soil bacteria with (semi)conductive iron-oxide minerals.

    PubMed

    Kato, Souichiro; Nakamura, Ryuhei; Kai, Fumiyoshi; Watanabe, Kazuya; Hashimoto, Kazuhito

    2010-12-01

    Pure-culture studies have shown that dissimilatory metal-reducing bacteria are able to utilize iron-oxide nanoparticles as electron conduits for reducing distant terminal acceptors; however, the ecological relevance of such energy metabolism is poorly understood. Here, soil microbial communities were grown in electrochemical cells with acetate as the electron donor and electrodes (poised at 0.2 V versus Ag/AgCl) as the electron acceptors in the presence and absence of iron-oxide nanoparticles, and respiratory current generation and community structures were analysed. Irrespective of the iron-oxide species (hematite, magnetite or ferrihydrite), the supplementation with iron-oxide minerals resulted in large increases (over 30-fold) in current, while only a moderate increase (∼10-fold) was observed in the presence of soluble ferric/ferrous irons. During the current generation, insulative ferrihydrite was transformed into semiconductive goethite. Clone-library analyses of 16S rRNA gene fragments PCR-amplified from the soil microbial communities revealed that iron-oxide supplementation facilitated the occurrence of Geobacter species affiliated with subsurface clades 1 and 2. We suggest that subsurface-clade Geobacter species preferentially thrive in soil by utilizing (semi)conductive iron oxides for their respiration. © 2010 Society for Applied Microbiology and Blackwell Publishing Ltd.

  3. KSC-2010-5961

    NASA Image and Video Library

    2010-12-29

    CAPE CANAVERAL, Fla. -- Inside the intertank of space shuttle Discovery's external fuel tank, a technician holds the film used to project computed radiography scans. The shuttle stack, consisting of the shuttle, external tank and solid rocket boosters, was moved from Launch Pad 39A to the Vehicle Assembly Building at NASA's Kennedy Space Center in Florida so technicians could examine 21-foot-long support beams, called stringers, on the outside of the tank's intertank and re-apply foam insulation. Discovery's next launch opportunity to the International Space Station on the STS-133 mission is no earlier than Feb. 3, 2011. For more information on STS-133, visit www.nasa.gov/mission_pages/shuttle/shuttlemissions/sts133/. Photo credit: NASA/Frankie Martin

  4. Cassidy and Marshburn during EVA-5

    NASA Image and Video Library

    2009-07-27

    S127-E-009342 (27 July 2009) --- Astronauts Tom Marshburn (foreground) and Christopher Cassidy, both STS-127 mission specialists, participate in the mission's fifth and final session of extravehicular activity (EVA) as construction and maintenance continue on the International Space Station. During the four-hour, 54-minute spacewalk, Marshburn and Cassidy secured multi-layer insulation around the Special Purpose Dexterous Manipulator known as Dextre, split out power channels for two space station Control Moment Gyroscopes, installed video cameras on the front and back of the new Japanese Exposed Facility and performed a number of “get ahead” tasks, including tying down some cables and installing handrails and a portable foot restraint to aid future spacewalkers.

  5. Cassidy during EVA-5

    NASA Image and Video Library

    2009-07-27

    S127-E-009315 (27 July 2009) --- Astronaut Christopher Cassidy, STS-127 mission specialist, participates in the mission's fifth and final session of extravehicular activity (EVA) as construction and maintenance continue on the International Space Station. During the four-hour, 54-minute spacewalk, Cassidy and astronaut Tom Marshburn (out of frame), mission specialist, secured multi-layer insulation around the Special Purpose Dexterous Manipulator known as Dextre, split out power channels for two space station Control Moment Gyroscopes, installed video cameras on the front and back of the new Japanese Exposed Facility and performed a number of “get ahead” tasks, including tying down some cables and installing handrails and a portable foot restraint to aid future spacewalkers.

  6. Cassidy and Marshburn during EVA-5

    NASA Image and Video Library

    2009-07-27

    S127-E-009312 (27 July 2009) --- Astronauts Tom Marshburn (left) and Christopher Cassidy, both STS-127 mission specialists, participate in the mission's fifth and final session of extravehicular activity (EVA) as construction and maintenance continue on the International Space Station. During the four-hour, 54-minute spacewalk, Marshburn and Cassidy secured multi-layer insulation around the Special Purpose Dexterous Manipulator known as Dextre, split out power channels for two space station Control Moment Gyroscopes, installed video cameras on the front and back of the new Japanese Exposed Facility and performed a number of “get ahead” tasks, including tying down some cables and installing handrails and a portable foot restraint to aid future spacewalkers.

  7. Cassidy and Marshburn during EVA-5

    NASA Image and Video Library

    2009-07-27

    S127-E-009317 (27 July 2009) --- Astronauts Tom Marshburn (left) and Christopher Cassidy, both STS-127 mission specialists, participate in the mission's fifth and final session of extravehicular activity (EVA) as construction and maintenance continue on the International Space Station. During the four-hour, 54-minute spacewalk, Marshburn and Cassidy secured multi-layer insulation around the Special Purpose Dexterous Manipulator known as Dextre, split out power channels for two space station Control Moment Gyroscopes, installed video cameras on the front and back of the new Japanese Exposed Facility and performed a number of “get ahead” tasks, including tying down some cables and installing handrails and a portable foot restraint to aid future spacewalkers.

  8. Cassidy and Marshburn during EVA-5

    NASA Image and Video Library

    2009-07-27

    S127-E-009329 (27 July 2009) --- Astronauts Christopher Cassidy and Tom Marshburn (partially out of frame at left), both STS-127 mission specialists, participate in the mission's fifth and final session of extravehicular activity (EVA) as construction and maintenance continue on the International Space Station. During the four-hour, 54-minute spacewalk, Marshburn and Cassidy secured multi-layer insulation around the Special Purpose Dexterous Manipulator known as Dextre, split out power channels for two space station Control Moment Gyroscopes, installed video cameras on the front and back of the new Japanese Exposed Facility and performed a number of “get ahead” tasks, including tying down some cables and installing handrails and a portable foot restraint to aid future spacewalkers.

  9. Cassidy and Marshburn during EVA-5

    NASA Image and Video Library

    2009-07-27

    S127-E-009323 (27 July 2009) --- Astronauts Tom Marshburn (foreground) and Christopher Cassidy, both STS-127 mission specialists, participate in the mission's fifth and final session of extravehicular activity (EVA) as construction and maintenance continue on the International Space Station. During the four-hour, 54-minute spacewalk, Marshburn and Cassidy secured multi-layer insulation around the Special Purpose Dexterous Manipulator known as Dextre, split out power channels for two space station Control Moment Gyroscopes, installed video cameras on the front and back of the new Japanese Exposed Facility and performed a number of “get ahead” tasks, including tying down some cables and installing handrails and a portable foot restraint to aid future spacewalkers.

  10. Marshburn during EVA-5

    NASA Image and Video Library

    2009-07-27

    S127-E-009303 (27 July 2009) --- Astronaut Tom Marshburn, STS-127 mission specialist, participates in the mission's fifth and final session of extravehicular activity (EVA) as construction and maintenance continue on the International Space Station. During the four-hour, 54-minute spacewalk, Marshburn and astronaut Christopher Cassidy (out of frame), mission specialist, secured multi-layer insulation around the Special Purpose Dexterous Manipulator known as Dextre, split out power channels for two space station Control Moment Gyroscopes, installed video cameras on the front and back of the new Japanese Exposed Facility and performed a number of “get ahead” tasks, including tying down some cables and installing handrails and a portable foot restraint to aid future spacewalkers.

  11. Cassidy and Marshburn during EVA-5

    NASA Image and Video Library

    2009-07-27

    S127-E-009363 (27 July 2009) --- Astronauts Tom Marshburn (foreground) and Christopher Cassidy, both STS-127 mission specialists, participate in the mission's fifth and final session of extravehicular activity (EVA) as construction and maintenance continue on the International Space Station. During the four-hour, 54-minute spacewalk, Marshburn and Cassidy secured multi-layer insulation around the Special Purpose Dexterous Manipulator known as Dextre, split out power channels for two space station Control Moment Gyroscopes, installed video cameras on the front and back of the new Japanese Exposed Facility and performed a number of “get ahead” tasks, including tying down some cables and installing handrails and a portable foot restraint to aid future spacewalkers.

  12. Cassidy and Marshburn during EVA-5

    NASA Image and Video Library

    2009-07-27

    S127-E-009372 (27 July 2009) --- Astronauts Tom Marshburn (left) and Christopher Cassidy, both STS-127 mission specialists, participate in the mission's fifth and final session of extravehicular activity (EVA) as construction and maintenance continue on the International Space Station. During the four-hour, 54-minute spacewalk, Marshburn and Cassidy secured multi-layer insulation around the Special Purpose Dexterous Manipulator known as Dextre, split out power channels for two space station Control Moment Gyroscopes, installed video cameras on the front and back of the new Japanese Exposed Facility and performed a number of “get ahead” tasks, including tying down some cables and installing handrails and a portable foot restraint to aid future spacewalkers.

  13. iss020e025085

    NASA Image and Video Library

    2009-07-27

    ISS020-E-025085 (27 July 2009) --- Astronaut Christopher Cassidy, STS-127 mission specialist, participates in the mission's fifth and final session of extravehicular activity (EVA) as construction and maintenance continue on the International Space Station. During the four-hour, 54-minute spacewalk, Cassidy and astronaut Tom Marshburn (out of frame), mission specialist, secured multi-layer insulation around the Special Purpose Dexterous Manipulator known as Dextre, split out power channels for two space station Control Moment Gyroscopes, installed video cameras on the front and back of the new Japanese Exposed Facility and performed a number of ?get ahead? tasks, including tying down some cables and installing handrails and a portable foot restraint to aid future spacewalkers.

  14. Cassidy during EVA-5

    NASA Image and Video Library

    2009-07-27

    S127-E-009248 (27 July 2009) --- Astronaut Christopher Cassidy, STS-127 mission specialist, participates in the mission's fifth and final session of extravehicular activity (EVA) as construction and maintenance continue on the International Space Station. During the four-hour, 54-minute spacewalk, Cassidy and astronaut Tom Marshburn (out of frame), mission specialist, secured multi-layer insulation around the Special Purpose Dexterous Manipulator known as Dextre, split out power channels for two space station Control Moment Gyroscopes, installed video cameras on the front and back of the new Japanese Exposed Facility and performed a number of “get ahead” tasks, including tying down some cables and installing handrails and a portable foot restraint to aid future spacewalkers.

  15. Cassidy during EVA-5

    NASA Image and Video Library

    2009-07-27

    S127-E-009347 (27 July 2009) --- Astronaut Christopher Cassidy, STS-127 mission specialist, participates in the mission's fifth and final session of extravehicular activity (EVA) as construction and maintenance continue on the International Space Station. During the four-hour, 54-minute spacewalk, Cassidy and astronaut Tom Marshburn (out of frame), mission specialist, secured multi-layer insulation around the Special Purpose Dexterous Manipulator known as Dextre, split out power channels for two space station Control Moment Gyroscopes, installed video cameras on the front and back of the new Japanese Exposed Facility and performed a number of “get ahead” tasks, including tying down some cables and installing handrails and a portable foot restraint to aid future spacewalkers.

  16. Cassidy and Marshburn during EVA-5

    NASA Image and Video Library

    2009-07-27

    S127-E-009371 (27 July 2009) --- Astronauts Tom Marshburn (left) and Christopher Cassidy, both STS-127 mission specialists, participate in the mission's fifth and final session of extravehicular activity (EVA) as construction and maintenance continue on the International Space Station. During the four-hour, 54-minute spacewalk, Marshburn and Cassidy secured multi-layer insulation around the Special Purpose Dexterous Manipulator known as Dextre, split out power channels for two space station Control Moment Gyroscopes, installed video cameras on the front and back of the new Japanese Exposed Facility and performed a number of “get ahead” tasks, including tying down some cables and installing handrails and a portable foot restraint to aid future spacewalkers.

  17. Analysis of observations of the Imhotep region of 67P/C-G performed by MIRO/Rosetta in 2014 and 2016 and derived constraints on the close subsurface properties

    NASA Astrophysics Data System (ADS)

    Lethuillier, Anthony; von Allmen, Paul; Hofstadter, Mark; Beaudin, Gerard; Biver, Nicolas; Bockelee-Morvan, Dominique; Choukroun, Mathieu; Crovisier, Jacques; Davidsson, Bjorn; Encrenaz, Pierre; Encrenaz, Therese; Frerking, Margaret; Gulkis, Samuel; Hartogh, Paul; Ip, Wing-Huen; Janssen, Michael A.; Jarchow, Christopher; Lee, Seungwon; Lellouch, Emmanuel; Leyrat, Cedric; Rezac, Ladislav; Schloerb, Peter; Spilker, Thomas R.; MIRO/Rosetta

    2017-10-01

    After the arrival of the Rosetta spacecraft at the 67P/ Churyumov-Gerasimenko comet in August 2014, and continuing until the end of mission in September 2016, the MIRO (Microwave Instrument for Rosetta Orbiter, Gulkis et al. [2007]) performed broadband, continuum measurements at 188 GHz (1.6 mm wavelength) and 562 GHz (0.5 mm wavelength) of the nucleus and coma. The instrument measured the thermal emission from the close subsurface over a wide range of spatial resolutions (20 - 500 m) and emission angles. The measurements revealed a seasonal and diurnal variation of the subsurface temperatures indicating that the submillimeter radiation originates from depths comparable to the diurnal thermal skin depth [Gulkis et al. 2015]. The observations were found to be consistent with very low thermal inertia values over most of the surface (between 10-60 J K-1 m-2 s-1/2, consistent with a thermally insulating powdered surface), and they suggest vertical heterogeneities and the possible presence of ice within the upper few centimeters of the surface (Schloerb et al. [2015]; Choukroun et al. [2015]). In addition to these global observations many studies are being done on specific parts of the nucleus, in this context we will present the work performed on high spatial resolutions observations of the Imhotep region. The Imhotep region, located on the main lobe of the nucleus, presents a smooth surface with no obvious impacts or depressions. This region was observed at least twice at high spatial resolution (approximately 18 m at submm wavelengths, 45 m in the millimeter), the first time on October 27th 2014 as a single swath observation then again on July 9th 2016 as a raster scan. Using a thermo-physical model developed at JPL to fit the observed thermal emission we will present the constraints we managed to obtain on the subsurface properties and their evolution over time.

  18. Nitrate Remediation of Soil and Groundwater Using Phytoremediation: Transfer of Nitrogen Containing Compounds from the Subsurface to Surface Vegetation

    NASA Astrophysics Data System (ADS)

    Nelson, Sheldon

    2013-04-01

    Nitrate Remediation of Soil and Groundwater Using Phytoremediation: Transfer of Nitrogen Containing Compounds from the Subsurface to Surface Vegetation Sheldon Nelson Chevron Energy Technology Company 6001 Bollinger Canyon Road San Ramon, California 94583 snne@chevron.com The basic concept of using a plant-based remedial approach (phytoremediation) for nitrogen containing compounds is the incorporation and transformation of the inorganic nitrogen from the soil and/or groundwater (nitrate, ammonium) into plant biomass, thereby removing the constituent from the subsurface. There is a general preference in many plants for the ammonium nitrogen form during the early growth stage, with the uptake and accumulation of nitrate often increasing as the plant matures. The synthesis process refers to the variety of biochemical mechanisms that use ammonium or nitrate compounds to primarily form plant proteins, and to a lesser extent other nitrogen containing organic compounds. The shallow soil at the former warehouse facility test site is impacted primarily by elevated concentrations of nitrate, with a minimal presence of ammonium. Dissolved nitrate (NO3-) is the primary dissolved nitrogen compound in on-site groundwater, historically reaching concentrations of 1000 mg/L. The initial phases of the project consisted of the installation of approximately 1750 trees, planted in 10-foot centers in the areas impacted by nitrate and ammonia in the shallow soil and groundwater. As of the most recent groundwater analytical data, dissolved nitrate reductions of 40% to 96% have been observed in monitor wells located both within, and immediately downgradient of the planted area. In summary, an evaluation of time series groundwater analytical data from the initial planted groves suggests that the trees are an effective means of transfering nitrogen compounds from the subsurface to overlying vegetation. The mechanism of concentration reduction may be the uptake of residual nitrate from the vadose zone, the direct uptake of dissolved constituent from the upper portion of the saturated zone/capillary fringe, or a combination of these two processes.

  19. Performance of a mullite reusable surface insulation system in a hypersonic stream

    NASA Technical Reports Server (NTRS)

    Hunt, L. R.

    1976-01-01

    The thermal and structural performance of a large panel of mullite reusable surface insulation (RSI) tiles was determined by a series of aerothermal tests in the Langley 8-foot high-temperature structures tunnel. The test panel was designed to represent a portion of the surface structure on a space shuttle orbiter fuselage along a 1,150 K isotherm with the mullite tile system bonded directly to the primary structure. Aerothermal tests were conducted at a free-stream Mach number of 6.7, a total temperature of 1,880 K, a unit Reynolds number of 4.6 million per meter, and dynamic pressure of 62 kPa. The thermal response of the mullite tile was as predicted, and the bond-line temperature did not exceed the design level of 570 K during a typical entry-heat cycle. Geometric irregularities of the tile gaps affected the tile edge temperatures when exposed to hypersonic flow. The tile coating demonstrated good toughness to particle impacts, but the coating cracked and flaked with thermal cycles. The gap filler of woven silica fibers appeared to hinder flow penetration into the gaps and withstood the flow shear of the present tests.

  20. Heating and Cooling Efficiency for Homes

    NASA Technical Reports Server (NTRS)

    2004-01-01

    Over 40 years ago, NASA developed Radiant Barrier technology to protect astronauts in the Apollo Program from temperatures that ranged from 250 F above to 400 F below zero Fahrenheit. This feat in temperature control technology enabled the astronauts to work inside the Apollo Command Module wearing short-sleeve shirts, with temperatures similar to those of a regular business office. The Radiant Barrier has been applied to virtually all spacecraft since then, including unmanned spacecraft with delicate instruments that need protection from temperature extremes. It is also applied to the astronauts space suits, protecting them during space walks. Made of aluminized polymer film, the Radiant Barrier both bars and lets in heat to maintain a consistent temperature in an environment where ordinary insulation methods will not suffice. The aluminization of the material provides a reflective surface that keeps more than 95 percent of the radiated energy in space from reaching the spacecraft s interior. In space suits, the thin and flexible material reflects the astronauts body heat back to them for warmth, while at the same time reflecting the sun s radiation away from them to keep them cool. Using conventional insulation, a space suit would have required a 7-foot-thick protective layer.

  1. Hypothermic general cold adaptation induced by local cold acclimation.

    PubMed

    Savourey, G; Barnavol, B; Caravel, J P; Feuerstein, C; Bittel, J H

    1996-01-01

    To study relationships between local cold adaptation of the lower limbs and general cold adaptation, eight subjects were submitted both to a cold foot test (CFT, 5 degrees C water immersion, 5 min) and to a whole-body standard cold air test (SCAT, 1 degree C, 2 h, nude at rest) before and after a local cold acclimation (LCA) of the lower limbs effected by repeated cold water immersions. The LCA induced a local cold adaptation confirmed by higher skin temperatures of the lower limbs during CFT and a hypothermic insulative general cold adaptation (decreased rectal temperature and mean skin temperature P < 0.05) without a change either in metabolic heat production or in lower limb skin temperatures during SCAT after LCA. It was concluded that local cold adaptation was related to the habituation process confirmed by decreased plasma concentrations of noradrenaline (NA) during LCA (P < 0.05). However, the hypothermic insulative general cold adaptation was unrelated either to local cold adaptation or to the habituation process, because an increased NA during SCAT after LCA (P < 0.05) was observed but was rather related to a "T3 polar syndrome" occurring during LCA.

  2. Space Shuttle AFRSI OMS pod environment test using model 81-0 test fixture in the Ames Research Center 9x7-foot supersonic wind tunnel (OS-314A/B/C)

    NASA Technical Reports Server (NTRS)

    Collette, J. G. R.

    1984-01-01

    A test was conducted in the NASA/Ames Research Center 9x7-foot Supersonic Wind Tunnel to help resolve an anomaly that developed during the STS-6 orbiter flight wherein sections of the Advanced Flexible Reusable Surface Insulation (AFRSI) covering the OMS pods suffered some damage. A one-third scale two-dimensional shell structure model of an OMS pod cross-section was employed to support the test articles. These consisted of 15 AFRSI blanket panels form-fitted over the shell structures for exposure to simulated flight conditions. Of six baseline blankets, two were treated with special surface coatings. Two other panels were configured with AFRSI sections removed from the OV099 orbiter vehicle after the STS-6 flight. Seven additional specimens incorporated alternative designs and repairs. Following a series of surface pressure calibration runs, the specimens were exposed to simulated ascent and entry dynamic pressure profiles. Entry conditions included the use of a vortex generator to evaluate the effect of shed vortices on the AFRSI located in the area of concern.

  3. AlGaN/GaN HEMTs regrown by MBE on epi-ready semi-insulating GaN-on-sapphire with inhibited interface contamination

    NASA Astrophysics Data System (ADS)

    Cordier, Y.; Azize, M.; Baron, N.; Chenot, S.; Tottereau, O.; Massies, J.

    2007-11-01

    In this work, we show that, by carefully designing the subsurface Fe doping profile in SI-GaN templates grown by MOVPE and by optimizing the MBE regrowth conditions, a highly resistive GaN buffer can be achieved on these epi-ready GaN-on-sapphire templates without any addition of acceptors during the regrowth. As a result, high-quality high electron mobility transistors can be fabricated. Furthermore, we report on the excellent properties of two-dimensional electron gas and device performances with electron mobility greater than 2000 cm 2/V s at room temperature and off-state buffer leakage currents as low as 5 μA/mm at 100 V.

  4. Supersonic stability and control characteristics of a 0.015 scale model 69-0 of the space shuttle orbiter with forebody RSI modifications in the NASA/LaRC 4-foot UPWT (legs 1 and 2) (LA71A/B)

    NASA Technical Reports Server (NTRS)

    1977-01-01

    Investigations are reported for the determination of aerodynamic effects of reducing the thickness of the reusable surface insulation located along the sides of the shuttle orbiter in order to allow weight reduction in the nose region. Six-component aerodynamic force and moment data were obtained at Mach numbers from 1.5 to 4.6 over an angle of attack range from about -1 deg to 28 deg. Additional tests were made over an angle of sideslip range from -6 deg to 6 deg at selected angles of attack. Test results are presented in graph and tables.

  5. Hydrogeologic data for the McKay Creek subsurface waste-injection test site, Pinellas County, Florida

    USGS Publications Warehouse

    Hickey, John D.

    1977-01-01

    Lithologic, hydraulic, geophysical, and water-quality data collected at the McKay Creek subsurface waste-injection test site in Pinellas County, Florida, are reported. Data were collected to determine the possibility of subsurface injection of waste-treatment plant effluent. One exploratory hole, one test injection well, and eight observation wells were constructed between May 1973 and February 1976. The exploratory hole was drilled to a depth of 1,750 feet below land surface; the test injection well is open in dolomite between 952 and 1 ,040 feet; and the observation wells are open to intervals above , in, and below the test injection zone. The lithology of the upper 100 feet is predominantly clay. From 100 to 1,750 feet below land surface, limestone and dolomite predominate. Gypsum is present 1,210 feet below land surface. Laboratory analyses of cores taken during drilling are given for vertical intrinsic permeability, porosity, interval transit time, and compressibility. Specific capacities tested during drilling range from 4 to 2,500 gallons per minute per foot of drawdown. An 83-hour withdrawal test at 4,180 gallons per minute and a 2-month injection test at 650 gallons per minute were run. Small water-quality changes were observed in one observation well immediately above the test injection zone during and after the injection test. Formation water in all of the wells with the exception of the shallowest observation wells is saline. The vertical position of saltwater is estimated to be at about 280 feet below land surface. Thirteen wells within a 1-mile radius of the test site were located and sampled for water quality. (USGS)

  6. Ground-water discharge determined from measurements of evapotranspiration, other available hydrologic components, and shallow water-level changes, Oasis Valley, Nye County, Nevada

    USGS Publications Warehouse

    Reiner, S.R.; Laczniak, R.J.; DeMeo, G.A.; Smith, J. LaRue; Elliott, P.E.; Nylund, W.E.; Fridrich, C.J.

    2002-01-01

    Oasis Valley is an area of natural ground-water discharge within the Death Valley regional ground-water flow system of southern Nevada and adjacent California. Ground water discharging at Oasis Valley is replenished from inflow derived from an extensive recharge area that includes the northwestern part of the Nevada Test Site (NTS). Because nuclear testing has introduced radionuclides into the subsurface of the NTS, the U.S. Department of Energy currently is investigating the potential transport of these radionuclides by ground water flow. To better evaluate any potential risk associated with these test-generated contaminants, a number of studies were undertaken to accurately quantify discharge from areas downgradient in the regional ground-water flow system from the NTS. This report refines the estimate of ground-water discharge from Oasis Valley. Ground-water discharge from Oasis Valley was estimated by quantifying evapotranspiration (ET), estimating subsurface outflow, and compiling ground-water withdrawal data. ET was quantified by identifying areas of ongoing ground-water ET, delineating areas of ET defined on the basis of similarities in vegetation and soil-moisture conditions, and computing ET rates for each of the delineated areas. A classification technique using spectral-reflectance characteristics determined from satellite imagery acquired in 1992 identified eight unique areas of ground-water ET. These areas encompass about 3,426 acres of sparsely to densely vegetated grassland, shrubland, wetland, and open water. Annual ET rates in Oasis Valley were computed with energy-budget methods using micrometeorological data collected at five sites. ET rates range from 0.6 foot per year in a sparse, dry saltgrass environment to 3.1 feet per year in dense meadow vegetation. Mean annual ET from Oasis Valley is estimated to be about 7,800 acre-feet. Mean annual ground-water discharge by ET from Oasis Valley, determined by removing the annual local precipitation component of 0.5 foot, is estimated to be about 6,000 acre-feet. Annual subsurface outflow from Oasis Valley into the Amargosa Desert is estimated to be between 30 and 130 acre-feet. Estimates of total annual ground-water withdrawal from Oasis Valley by municipal and non-municipal users in 1996 and 1999 are 440 acre-feet and 210 acre-feet, respectively. Based on these values, natural annual ground-water discharge from Oasis Valley is about 6,100 acre-feet. Total annual discharge was 6,500 acre-ft in 1996 and 6,300 acre-ft in 1999. This quantity of natural ground-water discharge from Oasis Valley exceeds the previous estimate made in 1962 by a factor of about 2.5. Water levels were measured in Oasis Valley to gain additional insight into the ET process. In shallow wells, water levels showed annual fluctuations as large as 7 feet and daily fluctuations as large as 0.2 foot. These fluctuations may be attributed to water loss associated with evapotranspiration. In shallow wells affected by ET, annual minimum depths to water generally occurred in winter or early spring shortly after daily ET reached minimum rates. Annual maximum depths to water generally occurred in late summer or fall shortly after daily ET reached maximum rates. The magnitude of daily water-level fluctuations generally increased as ET increased and decreased as depth to water increased.

  7. Samarium Hexaboride: The First True 3D Topological Insulator?

    NASA Astrophysics Data System (ADS)

    Wolgast, Steven G.

    The recent theoretical prediction of a topologically protected surface state in the mixed-valent insulator SmB6 has motivated a series of charge transport studies, which are presented here. It is first studied using a specialized configuration designed to distinguish bulk-dominated conduction from surface-dominated conduction. As the material is cooled below 4 K, it exhibits a crossover from thermally activated bulk transport to metallic surface conduction with a fully insulating bulk. The robustness and magnitude of the surface conductivity, as is manifest in the literature of SmB6, is strong evidence for the topological insulator (TI) metallic surface states predicted for this material. This resolves a decades-old puzzle surrounding the low-temperature behavior of SmB6. Next, the magnetotransport properties of the surface are investigated using a Corbino disk geometry, which can directly measure the conductivity of individual surfaces. Both (011) and (001) crystal surfaces show a strong negative magnetoresistance at all magnetic field angles, due primarily to changes in the carrier density. The low mobility value accounts for the failure so far to observe Shubnikov-de Haas oscillations below 95 T. Small variations in the mobility and temperature dependence suggest a suppression of Kondo scattering from native oxide-layer magnetic moments. At low fields, a dynamical field-sweep-rate-dependent hysteretic behavior is observed. It persists at the slowest sweep rates, and cannot be explained by quantum interference corrections; it is likely due to extrinsic effects such as the magnetocaloric effect or glassy ordering of the native oxide moments. Pulsed magnetic field measurements up to 60 T at temperatures throughout the crossover regime clearly distinguish the surface magnetoresistance from the bulk magnetoresistance. The bulk magnetoresistance is due to a reduction in the bulk gap with increasing magnetic field. Finally, small subsurface cracks formed in SmB6 via systematic scratching or sanding results in a counter-intuitive increase in the electrical conduction due to the unique surface-conducting property of TIs, strengthening the building case for SmB 6's topological nature. This material is attractive as a TI because its bulk is fully insulating at a readily achieved 2 K, but it presents a large number of scientific mysteries and experimental challenges for future research.

  8. A simple temperature-based method to estimate heterogeneous frozen ground within a distributed watershed model

    NASA Astrophysics Data System (ADS)

    Follum, Michael L.; Niemann, Jeffrey D.; Parno, Julie T.; Downer, Charles W.

    2018-05-01

    Frozen ground can be important to flood production and is often heterogeneous within a watershed due to spatial variations in the available energy, insulation by snowpack and ground cover, and the thermal and moisture properties of the soil. The widely used continuous frozen ground index (CFGI) model is a degree-day approach and identifies frozen ground using a simple frost index, which varies mainly with elevation through an elevation-temperature relationship. Similarly, snow depth and its insulating effect are also estimated based on elevation. The objective of this paper is to develop a model for frozen ground that (1) captures the spatial variations of frozen ground within a watershed, (2) allows the frozen ground model to be incorporated into a variety of watershed models, and (3) allows application in data sparse environments. To do this, we modify the existing CFGI method within the gridded surface subsurface hydrologic analysis watershed model. Among the modifications, the snowpack and frost indices are simulated by replacing air temperature (a surrogate for the available energy) with a radiation-derived temperature that aims to better represent spatial variations in available energy. Ground cover is also included as an additional insulator of the soil. Furthermore, the modified Berggren equation, which accounts for soil thermal conductivity and soil moisture, is used to convert the frost index into frost depth. The modified CFGI model is tested by application at six test sites within the Sleepers River experimental watershed in Vermont. Compared to the CFGI model, the modified CFGI model more accurately captures the variations in frozen ground between the sites, inter-annual variations in frozen ground depths at a given site, and the occurrence of frozen ground.

  9. Pit chains on Enceladus signal the recent tectonic dissection of the ancient cratered terrains

    NASA Astrophysics Data System (ADS)

    Martin, Emily S.; Kattenhorn, Simon A.; Collins, Geoffrey C.; Michaud, Robert L.; Pappalardo, Robert T.; Wyrick, Danielle Y.

    2017-09-01

    Enceladus is the first outer solar system body on which pit chains have been positively identified. We map the global distribution of pit chains and show that pit chains are among the youngest tectonic features on Enceladus's surface, concentrated in the cratered plains centered on Enceladus's Saturnian and anti-Saturnian hemispheres. Pit chains on Enceladus are interpreted as the surface expressions of subsurface dilational fractures underlying a cover of unconsolidated material, which we infer to be a geologically young cover of loose regolith that mantles the surface of Enceladus. A widespread layer of regolith may act to insulate the surface, which has implications for the thermal state of Enceladus's ice shell. The widespread distribution of pit chains across the cratered plains indicates that this ancient surface has recently been tectonically active.

  10. Imaging latex–carbon nanotube composites by subsurface electrostatic force microscopy

    DOE PAGES

    Patel, Sajan; Petty, Clayton W.; Krafcik, Karen Lee; ...

    2016-09-08

    Electrostatic modes of atomic force microscopy have shown to be non-destructive and relatively simple methods for imaging conductors embedded in insulating polymers. Here we use electrostatic force microscopy to image the dispersion of carbon nanotubes in a latex-based conductive composite, which brings forth features not observed in previously studied systems employing linear polymer films. A fixed-potential model of the probe-nanotube electrostatics is presented which in principle gives access to the conductive nanoparticle's depth and radius, and the polymer film dielectric constant. Comparing this model to the data results in nanotube depths that appear to be slightly above the film–air interface.more » Furthermore, this result suggests that water-mediated charge build-up at the film–air interface may be the source of electrostatic phase contrast in ambient conditions.« less

  11. First principle study of heterostructure of BaBi3-stanene for topological superconductor applications

    NASA Astrophysics Data System (ADS)

    Kore, Ashish; Singh, Poorva

    2018-05-01

    We have studied the heterostructure of BaBi3 (superconductor) and stanene (topological insulator) with the aim of inducing topological superconductivity in stanene, due to proximity with superconductor BaBi3. The density functional theory calculations have been done for 2D structure of BaBi3 as well as for monolayer of stanene, separately. We find that compared to bulk BaBi3, the 2D bandstructure has contributions coming from both Ba and Bi atoms, unlike bulk where only Bi-p states are contributing to the bandstructure. Surface reconstruction of surface and sub-surface layer of 2D BaBi3 is also evident. The bandstructure of heterostructure of BaBi3-stanene is expected to bring out explicit features of topological superconductivity and indicating the presence of Majorana fermions.

  12. Superconductivity and weak localization of PdxBi2Se3 whiskers at low temperatures

    NASA Astrophysics Data System (ADS)

    Druzhinin, Anatoly; Ostrovskii, Igor; Khoverko, Yuriy; Rogacki, Krzysztof; Liakh-Kaguy, Natalia

    2018-02-01

    The temperature dependencies of Bi2Se3 whiskers' resistance with Pd doping concentration of (1÷2)×1019 cm-3 where measured in the temperature range 1.5÷77 K. At temperature 5.3 K a sharp drop in the whisker resistance was found. The observed effect is likely connected with the contribution of two processes such as the electron localization and superconductivity at temperatures below 5.3 K. The magnetoresistance in the n-type conductivity Bi2Se3 whiskers with different doping concentration of palladium that correspond to metal side of the metal-insulator transition was studied at low temperatures and magnetic field 0÷10 T. The whisker magnetoconductance is considered in the framework of the weak antilocalization model and connected with subsurface layers of Bi2Se3 whiskers.

  13. Results of the application of seismic-reflection and electromagnetic techniques for near-surface hydrogeologic and environmental investigations at Fort Bragg, North Carolina

    USGS Publications Warehouse

    Meyer, M.T.; Fine, J.M.

    1997-01-01

    As part of the U.S. Geological Survey's Resource Conservation and Recovery Act, Facilities Investigations at Fort Bragg, North Carolina, selected geophysical techniques were evaluated for their usefulness as assessment tools for determining subsurface geology, delineating the areal extent of potentially contaminated landfill sites, and locating buried objects and debris of potential environmental concern. Two shallow seismic-reflection techniques (compression and shear wave) and two electromagnetic techniques (ground-penetrating radar and terrain conductivity) were evaluated at several sites at the U.S. Army Base. The electromagnetic techniques also were tested for tolerance to cultural noise, such as nearby fences, vehicles, and power lines. For the terrain conductivity tests, two instruments were used--the EM31 and EM34, which have variable depths of exploration. The shallowest reflection event was 70 feet below land surface observed in common-depth point, stacked compression-wave data from 24- and 12-fold shallow-seismic-reflection surveys. Several reflection events consistent with clay-sand interfaces between 70 and 120 feet below land surface, along with basement-saprolite surfaces, were imaged in the 24-fold, common- depth-point stacked data. 12-fold, common-depth-point stacked data set contained considerably more noise than the 24-fold, common-depth-point data, due to reduced shot-to-receiver redundancy. Coherent stacked reflection events were not observed in the 24-fold, common-depth-point stacked shear-wave data because of the partial decoupling of the shear- wave generator from the ground. At one site, ground-penetrating radar effectively delineated a shallow, 2- to 5-foot thick sand unit bounded by thin (less than 1 foot) clay layers. The radar signal was completely attenuated where the overlying and underlying clay units thickened and the sand unit thinned. The pene- tration depth of the radar signal was less than 10 feet below land surface. A slight increase in electromagnetic conductivity across shallow sampling EM31 and EM34 profiles provided corroborative evidence of the shallow, thickening clay units. Plots of raw EM31 and EM34 data provided no direct interpretable information to delineate sand and clay units in the shallow subsurface. At two sites, the ground-penetrating radar effectively delineated the lateral continuity of surficial sand units 5 to 25 feet in thickness and the tops of their underlying clay units. The effective exploration depth of the ground-penetrating radar was limited by the proximity of clay units to the subsurface and their thickness. The ground-penetrating radar delineated the areal extent and depth of cover at a previously unrecognized extension of a trench-like landfill underlying a vehicle salvage yard. Attenuation of the radar signal beneath the landfill cover and the adjacent subsurface clays made these two mediums indistinguishable by ground-penetrating radar; however, EM31 data indicated that the electrical conductivity of the landfill was higher than the subsurface material adjacent to the landfill. The EM31 and EM34 conductivity surveys defined the areal extent of a landfill whose boundaries were inaccurately mapped, and also identified the locations of an old dumpsite and waste incinerator site at another landfill. A follow-up ground-penetrating radar survey of the abandoned dumpsite showed incongruities in some of the shallow radar reflections interpreted as buried refuse dispersed throughout the landfill. The ground-penetrating radar and EM31 effectively delineated a shallow buried fuel-oil tank. Of the three electromagnetic instruments, the ground-penetrating radar with the shielded 100-megahertz antenna was the least affected by cultural noise followed, in order, by the EM31 and EM34. The combination of terrain- conductivity and ground-penetrating radar for the site assessment of the landfill provided a powerful means to identify the areal extent of the landfill, potenti

  14. Hybrid quantum and molecular mechanics embedded cluster models for chemistry on silicon and silicon carbide surfaces

    NASA Astrophysics Data System (ADS)

    Shoemaker, James Richard

    Fabrication of silicon carbide (SiC) semiconductor devices are of interest for aerospace applications because of their high-temperature tolerance. Growth of an insulating SiO2 layer on SiC by oxidation is a poorly understood process, and sometimes produces interface defects that degrade device performance. Accurate theoretical models of surface chemistry, using quantum mechanics (QM), do not exist because of the huge computational cost of solving Schrodinger's equation for a molecular cluster large enough to represent a surface. Molecular mechanics (MM), which describes a molecule as a collection of atoms interacting through classical potentials, is a fast computational method, good at predicting molecular structure, but cannot accurately model chemical reactions. A new hybrid QM/MM computational method for surface chemistry was developed and applied to silicon and SiC surfaces. The addition of MM steric constraints was shown to have a large effect on the energetics of O atom adsorption on SiC. Adsorption of O atoms on Si-terminated SiC(111) favors above surface sites, in contrast to Si(111), but favors subsurface adsorption sites on C- terminated SiC(111). This difference, and the energetics of C atom etching via CO2 desorption, can explain the observed poor performance of SiC devices in which insulating layers were grown on C-terminated surfaces.

  15. Space Shuttle Projects

    NASA Image and Video Library

    1989-06-03

    The Marshall Space Flight Center (MSFC) engineers test fired a 26-foot long, 100,000-pound-thrust solid rocket motor for 30 seconds at the MSFC east test area, the first test firing of the Modified NASA Motor (M-NASA Motor). The M-NASA Motor was fired in a newly constructed stand. The motor is 48-inches in diameter and was loaded with two propellant cartridges weighing a total of approximately 12,000 pounds. The purpose of the test was to learn more about solid rocket motor insulation and nozzle materials and to provide young engineers additional hands-on expertise in solid rocket motor technology. The test is a part of NASA's Solid Propulsion Integrity Program, that is to provide NASA engineers with the techniques, engineering tools, and computer programs to be able to better design, build, and verify solid rocket motors.

  16. Post-test data report for the space shuttle full-scale AFRSI sequence of environments test (OS-305-1 to -5) in the NASA/Ames Research Center 11x11-foot wind tunnel

    NASA Technical Reports Server (NTRS)

    Marshall, B. A.

    1984-01-01

    The Advanced Flexible Reusable Surface Insulation (AFRSI) test article was wind tunnel tested. The AFRSI was exposed to a simulated ascent airloads environment and data was obtained which could be used to support the AFRSI certification program. The AFRSI sequence of environments also included radiant heating (1500 degrees Fahrenheit) and wind/rain environments. The test article was wind/rain conditioned before each wind tunnel entry and was thermally conditioned after each wind tunnel entry. The AFRSI failed and the test was aborted before reaching the ascent environment. The AFRSI test article sequentially exposed to 50 wind/rain and 49 simulated entry thermal missions, as well as four wind tunnel entries equivalent to 40 ascent missions.

  17. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Keysa, T.P.

    Characteristics of design, construction, performance, and educational opportunity are described for a small, simple passive solar community center in Christian Bend, Tennessee. This 2500-square-foot structure was designed in cooperation with this community of 75 families by TVA architects and was built entirely by volunteer labor. An educational process paralleled all phases of this building, begining with programming sessions, continuing through design, construction, occupation, and operation of the space. The direct gain building utilizes energy planning in both the interior and exterior. Earth berming and utilization of natural topography aid in the building's compatibility with both summer and winter climatic events.more » In addition to microclimatic design, interior space planning aids in naturally tempering spaces from extremes in climate. Extensive use of buffer spaces, an airlock entry, and placement of glazing areas (for direct gain and natural and induced ventilation) aid in the natural energy utilization and distribution in the interior spaces. Unique aspects include a double roof, which aids both in prevention of heat loss and in induced ventilation, and other operable garage door type roll down insulated shutters over the south facing aperture areas utilized both as night insulation and as a radiation barrier. This is the other major unique factor in this building. It has been designed both as an energy efficient community center for business as usual, and as an evacuation point and temporary shelter in th event of natural (flood) or man-induced (nuclear) disaster.« less

  18. STS-103 crew take part in CEIT in PHSF

    NASA Technical Reports Server (NTRS)

    1999-01-01

    During a Crew Equipment Interface Test (CEIT), members of the STS-103 crew check out a portable foot restraint on the Flight Support System that will be used on the mission, repairing the Hubble Space Telescope. The seven-member crew comprises Commander Curtis L. Brown Jr., Pilot Scott J. Kelly, and Mission Specialists Steven L. Smith, C. Michael Foale (Ph.D.), John M. Grunsfeld (Ph.D), Claude Nicollier of Switzerland, and Jean-Frangois Clervoy of France. Nicollier and Clervoy are with the European Space Agency. Mission STS-103 is a 'call-up' due to the need to replace portions of the pointing system, the gyros, which have begun to fail on the Hubble Space Telescope. Although Hubble is operating normally and conducting its scientific observations, only three of its six gyroscopes are working properly. The gyroscopes allow the telescope to point at stars, galaxies and planets. The STS-103 crew will not only replace gyroscopes, it will also replace a Fine Guidance Sensor and an older computer with a new enhanced model, an older data tape recorder with a solid-state digital recorder, a failed spare transmitter with a new one, and degraded insulation on the telescope with new thermal insulation. The crew will also install a Battery Voltage/Temperature Improvement Kit to protect the spacecraft batteries from overcharging and overheating when the telescope goes into a safe mode. The scheduled launch date in October is under review.

  19. KSC-99pp1098

    NASA Image and Video Library

    1999-09-02

    During a Crew Equipment Interface Test (CEIT), members of the STS-103 crew check out a portable foot restraint on the Flight Support System that will be used on the mission, repairing the Hubble Space Telescope. The seven-member crew comprises Commander Curtis L. Brown Jr., Pilot Scott J. Kelly, and Mission Specialists Steven L. Smith, C. Michael Foale (Ph.D.), John M. Grunsfeld (Ph.D), Claude Nicollier of Switzerland, and Jean-François Clervoy of France. Nicollier and Clervoy are with the European Space Agency. Mission STS-103 is a "call-up" due to the need to replace portions of the pointing system, the gyros, which have begun to fail on the Hubble Space Telescope. Although Hubble is operating normally and conducting its scientific observations, only three of its six gyroscopes are working properly. The gyroscopes allow the telescope to point at stars, galaxies and planets. The STS-103 crew will not only replace gyroscopes, it will also replace a Fine Guidance Sensor and an older computer with a new enhanced model, an older data tape recorder with a solid-state digital recorder, a failed spare transmitter with a new one, and degraded insulation on the telescope with new thermal insulation. The crew will also install a Battery Voltage/Temperature Improvement Kit to protect the spacecraft batteries from overcharging and overheating when the telescope goes into a safe mode. The scheduled launch date in October is under review

  20. Exploring the shallow structure of the San Ramón thrust fault in Santiago, Chile (~33.5° S), using active seismic and electric methods

    NASA Astrophysics Data System (ADS)

    Díaz, D.; Maksymowicz, A.; Vargas, G.; Vera, E.; Contreras-Reyes, E.; Rebolledo, S.

    2014-08-01

    The crustal-scale west-vergent San Ramón thrust fault system, which lies at the foot of the main Andean Cordillera in central Chile, is a geologically active structure with manifestations of late Quaternary complex surface rupture on fault segments along the eastern border of the city of Santiago. From the comparison of geophysical and geological observations, we assessed the subsurface structural pattern that affects the sedimentary cover and rock-substratum topography across fault scarps, which is critical for evaluating structural models and associated seismic hazard along the related faults. We performed seismic profiles with an average length of 250 m, using an array of 24 geophones (Geode), with 25 shots per profile, to produce high-resolution seismic tomography to aid in interpreting impedance changes associated with the deformed sedimentary cover. The recorded travel-time refractions and reflections were jointly inverted by using a 2-D tomographic approach, which resulted in variations across the scarp axis in both the velocities and the reflections that are interpreted as the sedimentary cover-rock substratum topography. Seismic anisotropy observed from tomographic profiles is consistent with sediment deformation triggered by west-vergent thrust tectonics along the fault. Electrical soundings crossing two fault scarps were used to construct subsurface resistivity tomographic profiles, which reveal systematic differences between lower resistivity values in the hanging wall with respect to the footwall of the geological structure, and clearly show well-defined east-dipping resistivity boundaries. These boundaries can be interpreted in terms of structurally driven fluid content change between the hanging wall and the footwall of the San Ramón fault. The overall results are consistent with a west-vergent thrust structure dipping ~55° E in the subsurface beneath the piedmont sediments, with local complexities likely associated with variations in fault surface rupture propagation, fault splays and fault segment transfer zones.

  1. Exploring the shallow structure of the San Ramón thrust fault in Santiago, Chile (∼33.5° S), using active seismic and electric methods

    NASA Astrophysics Data System (ADS)

    Díaz, D.; Maksymowicz, A.; Vargas, G.; Vera, E.; Contreras-Reyes, E.; Rebolledo, S.

    2014-01-01

    The crustal-scale west-vergent San Ramón thrust fault system at the foot of the main Andean Cordillera in central Chile is a geologically active structure with Quaternary manifestations of complex surface rupture along fault segments in the eastern border of Santiago city. From the comparison of geophysical and geological observations, we assessed the subsurface structure pattern affecting sedimentary cover and rock-substratum topography across fault scarps, which is critic for evaluating structural modeling and associated seismic hazard along this kind of faults. We performed seismic profiles with an average length of 250 m, using an array of twenty-four geophones (GEODE), and 25 shots per profile, supporting high-resolution seismic tomography for interpreting impedance changes associated to deformed sedimentary cover. The recorded traveltime refractions and reflections were jointly inverted by using a 2-D tomographic approach, which resulted in variations across the scarp axis in both velocities and reflections interpreted as the sedimentary cover-rock substratum topography. Seismic anisotropy observed from tomographic profiles is consistent with sediment deformation triggered by west-vergent thrust tectonics along the fault. Electrical soundings crossing two fault scarps supported subsurface resistivity tomographic profiles, which revealed systematic differences between lower resistivity values in the hanging wall with respect to the footwall of the geological structure, clearly limited by well-defined east-dipping resistivity boundaries. The latter can be interpreted in terms of structurally driven fluid content-change between the hanging wall and the footwall of a permeability boundary associated with the San Ramón fault. The overall results are consistent with a west-vergent thrust structure dipping ∼55° E at subsurface levels in piedmont sediments, with local complexities being probably associated to fault surface rupture propagation, fault-splay and fault segment transfer zones.

  2. A nitride-based epitaxial surface layer formed by ammonia treatment of silicene-terminated ZrB{sub 2}

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wiggers, F. B., E-mail: F.B.Wiggers@utwente.nl; Van Bui, H.; Schmitz, J.

    We present a method for the formation of an epitaxial  surface layer involving B, N, and Si atoms on a ZrB{sub 2}(0001) thin film on Si(111). It has the potential to be an insulating growth template for 2D semiconductors. The chemical reaction of NH{sub 3} molecules with the silicene-terminated ZrB{sub 2}  surface was characterized by synchrotron-based, high-resolution core-level photoelectron spectroscopy and low-energy electron diffraction. In particular, the dissociative chemisorption of NH{sub 3} at 400 °C leads to surface  nitridation, and subsequent annealing up to 830 °C results in a solid phase reaction with the ZrB{sub 2} subsurface layers. In this way, amore » new nitride-based epitaxial  surface layer is formed with hexagonal symmetry and a single in-plane crystal orientation.« less

  3. Third-generation site characterization: Cryogenic core collection, nuclear magnetic resonance, and electrical resistivity

    NASA Astrophysics Data System (ADS)

    Kiaalhosseini, Saeed

    In modern contaminant hydrology, management of contaminated sites requires a holistic characterization of subsurface conditions. Delineation of contaminant distribution in all phases (i.e., aqueous, non-aqueous liquid, sorbed, and gas), as well as associated biogeochemical processes in a complex heterogeneous subsurface, is central to selecting effective remedies. Arguably, a factor contributing to the lack of success of managing contaminated sites effectively has been the limitations of site characterization methods that rely on monitoring wells and grab sediment samples. The overarching objective of this research is to advance a set of third-generation (3G) site characterization methods to overcome shortcomings of current site characterization techniques. 3G methods include 1) cryogenic core collection (C3) from unconsolidated geological subsurface to improve recovery of sediments and preserving key attributes, 2) high-throughput analysis (HTA) of frozen core in the laboratory to provide high-resolution, depth discrete data of subsurface conditions and processes, 3) resolution of non-aqueous phase liquid (NAPL) distribution within the porous media using a nuclear magnetic resonance (NMR) method, and 4) application of a complex resistivity method to track NAPL depletion in shallow geological formation over time. A series of controlled experiments were conducted to develop the C 3 tools and methods. The critical aspects of C3 are downhole circulation of liquid nitrogen via a cooling system, the strategic use of thermal insulation to focus cooling into the core, and the use of back pressure to optimize cooling. The C3 methods were applied at two contaminated sites: 1) F.E. Warren (FEW) Air Force Base near Cheyenne, WY and 2) a former refinery in the western U.S. The results indicated that the rate of core collection using the C3 methods is on the order of 30 foot/day. The C3 methods also improve core recovery and limits potential biases associated with flowing sands. HTA of frozen core was employed at the former refinery and FEW. Porosity and fluid saturations (i.e., aqueous, non-aqueous liquid, and gas) from the former refinery indicate that given in situ freezing, the results are not biased by drainage of pore fluids from the core during sample collection. At FEW, a comparison between the results of HTA of the frozen core collected in 2014 and the results of site characterization using unfrozen core, (second-generation (2G) methods) at the same locations (performed in 2010) indicate consistently higher contaminant concentrations using C 3. Many factors contribute to the higher quantification of contaminant concentrations using C3. The most significant factor is the preservation of the sediment attributes, in particular, pore fluids and volatile organic compounds (VOCs) in comparison to the unfrozen conventional sediment core. The NMR study was performed on laboratory-fabricated sediment core to resolve NAPL distribution within the porous media qualitatively and quantitatively. The fabricated core consisted of Colorado silica sand saturated with deionized water and trichloroethylene (TCE). The cores were scanned with a BRUKER small-animal scanner (2.3 Tesla, 100 MHz) at 20 °C and while the core was frozen at -25 °C. The acquired images indicated that freezing the water within the core suppressed the NMR signals of water-bound hydrogen. The hydrogen associated with TCE was still detectable since the TCE was in its liquid state (melting point of TCE is -73 °C). Therefore, qualitative detection of TCE within the sediment core was performed via the NMR scanning by freezing the water. A one-dimensional NMR scanning method was used for quantification of TCE mass distribution within the frozen core. However, the results indicated inconsistency in estimating the total TCE mass within the porous media. Downhole NMR logging was performed at the former refinery in the western U.S. to detect NAPL and to discriminate NAPL from water in the formation. The results indicated that detection of NMR signals to discriminate NAPL from water is compromised by the noise stemming from the active facilities and/or power lines passing over the site. A laboratory experiment was performed to evaluate the electrical response of unconsolidated porous media through time (30 days) while NAPL was being depleted. Sand columns (Colorado silica sand) contaminated with methyl tert-butyl ether (MTBE, a light non-aqueous phase liquid (LNAPL)) were studied. A multilevel electrode system was used to measure electrical resistivity of impacted sand by imposing alternative current. The trend of reduction in resistivity through the depth of columns over time followed depletion of LNAPL by volatilization. Finally, a field experiment was performed at the former refinery in the western U.S. to track natural losses of LNAPL over time. Multilevel systems consisting of water samplers, thermocouples, and electrodes were installed at a clean zone (background zone) and an LNAPL-impacted zone. In situ measurements of complex resistivity and temperature were taken and water sampling was performed for each depth (from 3 to 14 feet below the ground surface at one-foot spacing) within almost a year. At both locations, the results indicated decreases in apparent resistivity below the water table over time. This trend was supported by the geochemistry of the pore fluids. Overall, results indicate that application of the electrical resistivity method to track LNAPL depletion at field sites is difficult due to multiple conflicting factors affecting the geoelectrical response of LNAPL-impacted zones over time.

  4. KSC-99pp1439

    NASA Image and Video Library

    1999-12-17

    An olivaceous cormorant soars in the cloud-streaked sky near the Space Shuttle Discovery as it waits for liftoff on mission STS-103. To the left of Discovery is the Rotating Service Structure, rolled back on Dec. 16 in preparation for launch. At right is a 290-foot-high water tank with a capacity of 300,000 gallons. The tank is part of the sound suppression water system used during launch. The STS-103 mission, to service the Hubble Space Telescope, is scheduled for launch Dec. 17 at 8:47 p.m. EST from Launch Pad 39B. Mission objectives include replacing gyroscopes and an old computer, installing another solid state recorder, and replacing damaged insulation in the telescope. The mission is expected to last about 8 days and 21 hours. Discovery is expected to land at KSC Sunday, Dec. 26, at about 6:25 p.m. EST

  5. Analysis the configuration of earthing system based on high-low and low-high soil structure

    NASA Astrophysics Data System (ADS)

    Ramani, A. N.; Ahmad, Abdul Rahman; Sulaima, M. F.; Nasir, M. N. M.; Ahmad, Arfah

    2015-05-01

    Each TNB transmission tower requires a tower footing resistance (TFR) with a lower grounding resistance value that depends on the transmission line voltage. For 132kV and 275kV tower, the TFR must less than 10Ω and 500kV tower must less than 5Ω. The TFR is changeable with variable factors such as soil resistivity. Low TFR provides essential protection to the fault such as lightning strike that may occur at any time. The fault current flow to the lowest resistance path and easily disperses to earth. Back flashover voltage across the insulator of transmission lines may occur when the TFR is high. The TFR is influenced by soil resistivity. There are three parameters affecting the soil resistivity; moisture content, salt content and temperature of the soil. High moisture content in soil will reduce the soil resistivity and resultant low TFR. Small scale moisture control by using Micro Reservoir (MR) irrigation with semi-permeable membranes have the power to offer the stable moisture in soil. By using osmosis concept, it is the process of net movement of water molecules from high potential water to lower potential water though a semi permeable membrane. The MR can withstand for 3 to 5 days without continuous water supply. The MR installed in the centre of the tower that contains a multiple parallel of electrode rods. The concentrated of electrode rods grounding configuration with a combination of MR will improve the TFR even at multilayer soil. As a result, MR gives a little improvement to TFR. The MR in area of concentrated electrode rod configuration to ensure the soil always wet and moist at all times. The changes in soil affect the tower-footing-resistance. The tower-footing-resistance measurement at afternoon is higher than at evening because of the temperature and moisture content in soil is change due to sun radiation.

  6. Analysis the configuration of earthing system based on high-low and low-high soil structure

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ramani, A. N.; Ahmad, Abdul Rahman; Sulaima, M. F.

    2015-05-15

    Each TNB transmission tower requires a tower footing resistance (TFR) with a lower grounding resistance value that depends on the transmission line voltage. For 132kV and 275kV tower, the TFR must less than 10Ω and 500kV tower must less than 5Ω. The TFR is changeable with variable factors such as soil resistivity. Low TFR provides essential protection to the fault such as lightning strike that may occur at any time. The fault current flow to the lowest resistance path and easily disperses to earth. Back flashover voltage across the insulator of transmission lines may occur when the TFR is high.more » The TFR is influenced by soil resistivity. There are three parameters affecting the soil resistivity; moisture content, salt content and temperature of the soil. High moisture content in soil will reduce the soil resistivity and resultant low TFR. Small scale moisture control by using Micro Reservoir (MR) irrigation with semi-permeable membranes have the power to offer the stable moisture in soil. By using osmosis concept, it is the process of net movement of water molecules from high potential water to lower potential water though a semi permeable membrane. The MR can withstand for 3 to 5 days without continuous water supply. The MR installed in the centre of the tower that contains a multiple parallel of electrode rods. The concentrated of electrode rods grounding configuration with a combination of MR will improve the TFR even at multilayer soil. As a result, MR gives a little improvement to TFR. The MR in area of concentrated electrode rod configuration to ensure the soil always wet and moist at all times. The changes in soil affect the tower-footing-resistance. The tower-footing-resistance measurement at afternoon is higher than at evening because of the temperature and moisture content in soil is change due to sun radiation.« less

  7. Structural predictions for Correlated Electron Materials Using the Functional Dynamical Mean Field Theory Approach

    NASA Astrophysics Data System (ADS)

    Haule, Kristjan

    2018-04-01

    The Dynamical Mean Field Theory (DMFT) in combination with the band structure methods has been able to address reach physics of correlated materials, such as the fluctuating local moments, spin and orbital fluctuations, atomic multiplet physics and band formation on equal footing. Recently it is getting increasingly recognized that more predictive ab-initio theory of correlated systems needs to also address the feedback effect of the correlated electronic structure on the ionic positions, as the metal-insulator transition is almost always accompanied with considerable structural distortions. We will review recently developed extension of merger between the Density Functional Theory (DFT) and DMFT method, dubbed DFT+ embedded DMFT (DFT+eDMFT), whichsuccessfully addresses this challenge. It is based on the stationary Luttinger-Ward functional to minimize the numerical error, it subtracts the exact double-counting of DFT and DMFT, and implements self-consistent forces on all atoms in the unit cell. In a few examples, we will also show how the method elucidated the important feedback effect of correlations on crystal structure in rare earth nickelates to explain the mechanism of the metal-insulator transition. The method showed that such feedback effect is also essential to understand the dynamic stability of the high-temperature body-centered cubic phase of elemental iron, and in particular it predicted strong enhancement of the electron-phonon coupling over DFT values in FeSe, which was very recently verified by pioneering time-domain experiment.

  8. Engineer Examines Cluster of Ion Engines in the Electric Propulsion Laboratory

    NASA Image and Video Library

    1963-01-21

    New staff member Paul Margosian inspects a cluster of ion engines in the Electric Propulsion Laboratory’s 25-foot diameter vacuum tank at the National Aeronautics and Space Administration (NASA) Lewis Research Center. Lewis researchers had been studying different methods of electric rocket propulsion since the mid-1950s. Harold Kaufman created the first successful engine, the electron bombardment ion engine, in the early 1960s. These engines used electric power to create and accelerate small particles of propellant material to high exhaust velocities. Electric engines have a very small thrust, and but can operate for long periods of time. The ion engines are often clustered together to provide higher levels of thrust. The Electric Propulsion Laboratory contained two large vacuum tanks capable of simulating the space environment. The tanks were designed especially for testing ion and plasma thrusters and spacecraft. The larger 25-foot diameter tank was intended for testing electric thrusters with condensable propellants. The tank’s test compartment, seen here, was 10 feet in diameter. Margosian joined Lewis in late 1962 during a major NASA hiring phase. The Agency reorganized in 1961 and began expanding its ranks through a massive recruiting effort. Lewis personnel increased from approximately 2,700 in 1961 to over 4,800 in 1966. Margosian, who worked with Bill Kerslake in the Electromagnetic Propulsion Division’s Propulsion Systems Section, wrote eight technical reports on mercury and electron bombardment thrusters, thermoelectrostatic generators, and a high voltage insulator.

  9. New insights into the ground thermal regime of talus slopes with permafrost below the timberline

    NASA Astrophysics Data System (ADS)

    Schwindt, Daniel; Kneisel, Christof

    2013-04-01

    In the central Alps permafrost can be expected above 2400 m a.s.l., at altitudes where mean annual air temperatures are below -1° C. However, isolated permafrost occurrences are present in north-exposed talus slopes, far below the timberline, where mean annual air temperatures are positive. Driving factors are assumed to be a low income of solar radiation, a thick organic layer with high insulation capacities as well as the thermally induced chimney effect (Wakonigg, 1996). Investigated are three talus slopes with permafrost in the Swiss Alps that differ with regard to elevation level, talus material, humus characteristics and vegetation composition as well as the mean annual air temperatures. Aim is to achieve a deeper understanding of the factors determining the site-specific thermal regime, as well as the spatially limited and temporally highly variable permafrost occurrences in vegetated talus slopes. Focus is not solely on the question of why permafrost exists at these sites, but also why permafrost does not exist in the immediate surroundings. To detect the temporal variability and spatial heterogeneity of the permafrost occurrences, electrical resistivity tomography monitoring, seismic refraction tomography monitoring, and quasi-3D ERT were applied. To determine the ground thermal regime, air-, ground surface-, and humus temperatures, as well as temperatures within vents of the chimneys were recorded. Furthermore, humus characteristics (thickness, -temperature and -moisture) were mapped in permafrost-affected slope areas and in the immediate surroundings. To test the correlation between solar radiation, permafrost distribution, and humus/vegetation composition, digital elevation models were used to calculate the income of solar radiation. The areal extent of the permafrost bodies coincide precisely with slope sections where the organic layer is thickest, a consistent moss cover is present, and where temperatures at the transition between humus layer and talus material are lowest. The interaction of factors driving the ground thermal regime turned out to be more complex than assumed with differences between the investigated sites. Besides convective heat transport of the chimney effect, conductive heat flow within the humus layer strongly influences the ground thermal regime. Supercooling of the talus material in winter and autumn is aggravated by a high thermal conductivity of the organic material under frozen and wet conditions. The preservation of permafrost is favoured by the high insulation capacity of dry organic material in summer and by a prolonged zero-curtain period of up to 3 months - driven by high water-storage capacity of the organic material - that buffers the propagation of warm temperatures into the subsurface in spring. The income of solar radiation at the foot of the slope does not state a major driving factor for the occurrence of permafrost. Variability is low between areas with and without permafrost. In fact, differences were detected upslope, below the rock-walls, with summer-values being lowest in areas above the permafrost occurrences. It must be assumed that this affects the thermal circulation of the chimney effect during summer and favours the persistence of frozen ground in spatially limited slope areas.

  10. The Impact of Fire on Active Layer Thicknes

    NASA Astrophysics Data System (ADS)

    Schaefer, K. M.; Parsekian, A.; Natali, S.; Ludwig, S.; Michaelides, R. J.; Zebker, H. A.; Chen, J.

    2016-12-01

    Fire influences permafrost thermodynamics by darkening the surface to increase solar absorption and removing insulating moss and organic soil, resulting in an increase in Active Layer Thickness (ALT). The summer of 2015 was one of the worst fire years on record in Alaska with multiple fires in the Yukon-Kuskokwim (YK) Delta. To understand the impacts of fire on permafrost, we need large-scale, extensive measurements of ALT both within and outside the fire zones. In August 2016, we surveyed ALT across multiple fire zones in the YK Delta using Ground Penetrating Radar (GPR) and mechanical probing. GPR uses pulsed, radio-frequency electromagnetic waves to noninvasively image the subsurface and is an effective tool to quickly map ALT over large areas. We supplemented this ALT data with measurements of Volumetric Water Content (VWC), Organic Layer Thickness (OLT), and burn severity. We quantified the impacts of fire by statistically comparing the measurements inside and outside the fire zones and statistically regressing ALT against VWC, change in OLT, and burn severity.

  11. Volcanotectonic history of Crater Flat, southwestern Nevada, as suggested by new evidence from drill hole USW-VH-1 and vicinity

    USGS Publications Warehouse

    Carr, W.J.

    1982-01-01

    New evidence for a possible resurgent dome in the caldera related to eruption of the Bullfrog Member of the Crater Flat Tuff has been provided by recent drilling of a 762-meter (2,501-foot) hole in central Crater Flat. Although no new volcanic units were penetrated by the drill hole (USW-VH-1), the positive aeromagnetic anomaly in the vicinity of the drill hole appears to result in part from the unusually thick, densely welded tuff of the Bullfrog. Major units penetrated include alluvium, basalt of Crater Flat, Tiva Canyon and Topopah Spring Members of the Paintbrush Tuff, and Prow Pass and Bullfrog Members of the Crater Flat Tuff. In addition, the drill hole provided the first subsurface hydrologic information for the area. The water table in the hole is at about 180 meters (600 feet), and the temperature gradient appears slightly higher than normal for the region.

  12. Seismic investigation of Infiltration Through a Playa of the Llano Estacado Region of Texas

    NASA Astrophysics Data System (ADS)

    Fernandez-Canel, A.; Gurrola, H.; Taylor, L.; Abila, H.; Oviedo, R.; Harry, E.; Garza, J.

    2017-12-01

    Most of the population and economy of the south central United States (the bread baskets of the United States) is heavily dependent on the Ogallala aquifer as the main water resource. The overexploitation of the Ogallala aquifer can have catastrophic consequences. This project is a seismic investigation of the hydraulic behavior of the playa lakes of the southern high plains which are considered the main recharge source for the Ogallala. We deployed Texans (Ref Tek RT125A) data loggers with 4.5 Hz single component geophones before and after rain events and after controlled infiltration test to provide a data set to investigate infiltration pathways through the playas. The playa is about eight miles northeast of Lubbock, Texas. We refer to it as compartmentalized because it appears to be two very closely spaced playa; one of which retains water more efficiently than the other. The infiltration tests included the use of 4x8 foot infiltrometers and a 50 foot soaker hose in a compartmentalized playa. Preliminary results from analysis of two repeated profiles suggest that the seismic velocities beneath the infiltrometers and the soaker hose were lower than before flooding. These results suggest that measurements of seismic P-wave velocities may be useful to model the pathway for infiltration through the subsurface of the playa. We have collected (and will continue to collect) additional data sets following rain storms and infiltration test for a few months. We will present the results of these tests at the AGU meeting.

  13. Shallow Chamber & Conduit Behavior of Silicic Magma: A Thermo- and Fluid- Dynamic Parameterization Model of Physical Deformation as Constrained by Geodetic Observations: Case Study; Soufriere Hills Volcano, Montserrat

    NASA Astrophysics Data System (ADS)

    Gunn de Rosas, C. L.

    2013-12-01

    The Soufrière Hills Volcano, Montserrat (SHV) is an active, mainly andesitic and well-studied stratovolcano situated at the northern end of the Lesser Antilles Arc subduction zone in the Caribbean Sea. The goal of our research is to create a high resolution 3D subsurface model of the shallow and deeper aspects of the magma storage and plumbing system at SHV. Our model will integrate inversions using continuous and campaign geodetic observations at SHV from 1995 to the present as well as local seismic records taken at various unrest intervals to construct a best-fit geometry, pressure point source and inflation rate and magnitude. We will also incorporate a heterogeneous media in the crust and use the most contemporary understanding of deep crustal- or even mantle-depth 'hot-zone' genesis and chemical evolution of silicic and intermediate magmas to inform the character of the deep edifice influx. Our heat transfer model will be constructed with a modified 'thin shell' enveloping the magma chamber to simulate the insulating or conducting influence of heat-altered chamber boundary conditions. The final forward model should elucidate observational data preceding and proceeding unrest events, the behavioral suite of magma transport in the subsurface environment and the feedback mechanisms that may contribute to eruption triggering. Preliminary hypotheses suggest wet, low-viscosity residual melts derived from 'hot zones' will ascend rapidly to shallower stall-points and that their products (eventually erupted lavas as well as stalled plutonic masses) will experience and display two discrete periods of shallow evolution; a rapid depressurization crystallization event followed by a slower conduction-controlled heat transfer and cooling crystallization. These events have particular implications for shallow magma behaviors, notably inflation, compressibility and pressure values. Visualization of the model with its inversion constraints will be affected with ComSol. Conclusions about the subsurface behavioral suite at SHV will have high applicability to other silicic and intermediate volcanic edifices and may aid in the hazard mitigation associated with volcanic unrest.

  14. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shedlock, Daniel; Dugan, Edward T.; Jacobs, Alan M.

    X-ray backscatter radiography by selective detection (RSD) is a field tested and innovative approach to non-destructive evaluation (NDE). RSD is an enhanced single-side x-ray Compton backscatter imaging (CBI) technique which selectively detects scatter components to improve image contrast and quality. Scatter component selection is accomplished through a set of specially designed detectors with fixed and movable collimators. Experimental results have shown that this NDE technique can be used to detect boric acid deposition on a metallic plate through steel foil reflective insulation commonly covering reactor pressure vessels. The current system is capable of detecting boric acid deposits with sub-millimeter resolution,more » through such insulating materials. Industrial systems have been built for Lockheed Martin Space Co. and NASA. Currently the x-ray backscatter RSD scanning systems developed by the University of Florida are being used to inspect the spray-on foam insulation (SOFI) used on the external tank of the space shuttle. RSD inspection techniques have found subsurface cracking in the SOFI thought to be responsible for the foam debris which separated from the external tank during the last shuttle launch. These industrial scanning systems can be customized for many applications, and a smaller, lighter, more compact unit design is being developed. The smaller design is approximately four inches wide, three inches high, and about 12 inches in length. This smaller RSD system can be used for NDE of areas that cannot be reached with larger equipment. X-ray backscatter RSD is a proven technology that has been tested on a wide variety of materials and applications. Currently the system has been used to inspect materials such as aluminum, plastics, honeycomb laminates, reinforced carbon composites, steel, and titanium. The focus of RSD is for one-sided detection for applications where conventional non-destructive examination methods either will not work or give poor results. Acquired images have clearly shown, for a variety of conditions, that proper selection of x-ray field scatter components leads to a significant improvement in image quality and contrast. Improvements are significant enough in some cases that objects not visible to conventional CBI or transmission radiography become readily discernable with RSD. (authors)« less

  15. The PKI collector

    NASA Astrophysics Data System (ADS)

    Rice, M. P.

    1982-07-01

    The design and manufacturing of a solar thermal collector is discussed. The collector has three primary subsystems: concentrator, receiver/fluid loop, and controls. Identical curved reflective columns are utilized in a faceted Fresnel design to support 864 one foot square flat inexpensive second-surface, silvered glass mirrors. The columns are ganged together and rotated through their centers of gravity to provide elevation tracking. The concentrator is supported by a lightweight spaceframe structure which distributes all wind and gravity loads to the base supports. The base of the structure is a track which rotates on wheels mounted on concrete piers. A parallel tube steel heat exchanger is mounted at the concentrator focal area in a well insulated, galvanized steel housing. Two rows of vertical close-packed, staggered tubes connect a mud header and a steam header. Automatic two axis tracking and operational control is provided with a microprocessor based package. Concentrator-mounted shadowbands are the basis for active tracking. A software program provides azimuthal tracking during cloudy periods.

  16. The PKI collector

    NASA Technical Reports Server (NTRS)

    Rice, M. P.

    1982-01-01

    The design and manufacturing of a solar thermal collector is discussed. The collector has three primary subsystems: concentrator, receiver/fluid loop, and controls. Identical curved reflective columns are utilized in a faceted Fresnel design to support 864 one foot square flat inexpensive second-surface, silvered glass mirrors. The columns are ganged together and rotated through their centers of gravity to provide elevation tracking. The concentrator is supported by a lightweight spaceframe structure which distributes all wind and gravity loads to the base supports. The base of the structure is a track which rotates on wheels mounted on concrete piers. A parallel tube steel heat exchanger is mounted at the concentrator focal area in a well insulated, galvanized steel housing. Two rows of vertical close-packed, staggered tubes connect a mud header and a steam header. Automatic two axis tracking and operational control is provided with a microprocessor based package. Concentrator-mounted shadowbands are the basis for active tracking. A software program provides azimuthal tracking during cloudy periods.

  17. A review of historical exposures to asbestos among skilled craftsmen (1940-2006).

    PubMed

    Williams, Pamela R D; Phelka, Amanda D; Paustenbach, Dennis J

    2007-01-01

    This article provides a review and synthesis of the published and selected unpublished literature on historical asbestos exposures among skilled craftsmen in various nonshipyard and shipyard settings. The specific crafts evaluated were insulators, pipefitters, boilermakers, masons, welders, sheet-metal workers, millwrights, electricians, carpenters, painters, laborers, maintenance workers, and abatement workers. Over 50 documents were identified and summarized. Sufficient information was available to quantitatively characterize historical asbestos exposures for the most highly exposed workers (insulators), even though data were lacking for some job tasks or time periods. Average airborne fiber concentrations collected for the duration of the task and/or the entire work shift were found to range from about 2 to 10 fibers per cubic centimeter (cm3 or cc) during activities performed by insulators in various nonshipyard settings from the late 1960s and early 1970s. Higher exposure levels were observed for this craft during the 1940s to 1950s, when dust counts were converted from millions of particles per cubic foot (mppcf) to units of fibers per cubic centimeter (fibers/cc) using a 1:6 conversion factor. Similar tasks performed in U.S. shipyards yielded average fiber concentrations about two-fold greater, likely due to inadequate ventilation and confined work environments; however, excessively high exposure levels were reported in some British Naval shipyards due to the spraying of asbestos. Improved industrial hygiene practices initiated in the early to mid-1970s were found to reduce average fiber concentrations for insulator tasks approximately two- to five-fold. For most other crafts, average fiber concentrations were found to typically range from <0.01 to 1 fibers/cc (depending on the task or time period), with higher concentrations observed during the use of powered tools, the mixing or sanding of drywall cement, and the cleanup of asbestos insulation or lagging materials. The available evidence suggests that although many historical measurements exceeded the current OSHA 8-h time-weighted average (TWA) permissible exposure limit (PEL) of 0.1 fibers/cc, average fiber concentrations generally did not exceed historical occupational exposure limits in place at the time, except perhaps during ripout activities or the spraying of asbestos in enclosed spaces or onboard ships. Additionally, reported fiber concentrations may not have represented daily or actual human exposures to asbestos, since few samples were collected beyond specific short-term tasks and workers sometimes wore respiratory protective equipment. The available data were not sufficient to determine whether the airborne fiber concentrations represented serpentine or amphibole asbestos fibers, which would have a pronounced impact on the potential health hazards posed by the asbestos. Despite a number of limitations associated with the available air sampling data, the information should provide guidance for reconstructing asbestos exposures for different crafts in specific occupational settings where asbestos was present during the 1940 to 2006 time period.

  18. Electromagnetic Measurements in an Active Oilfield Environment

    NASA Astrophysics Data System (ADS)

    Weiss, C. J.; Aur, K. A.; Schramm, K. A.; Aldridge, D. F.; O'rourke, W. T.

    2016-12-01

    An important issue in oilfield development is mapping fracture distributions (either natural or man-made) controlling subsurface fluid flow. Although microseismic monitoring has been successful in constraining fracture system geometry and dynamics, accurate interpretation of microseismic data can be confounded by factors such as complex or poorly-understood velocity distributions, reactivation of previously unknown faults and fractures, and the problem of relating flow patterns to the cloud of hypocenter locations. For the particular problem of hydrocarbon production, the question of which fractures remain sufficiently "open" to allow economical fluid extraction is critical. As a supplement to microseismic analysis, we are investigating a novel electromagnetic (EM) technique for detecting and mapping hydraulic fractures in a hydrocarbon or geothermal reservoir by introducing an electrically conductive contrast agent into the fracturing fluid. In the field experiment presented here, a proppant-filled fracture zone is illuminated by a large engineered antenna consisting of an insulated current-carrying cable, grounded to `Earth' near the wellhead, and grounded at the other end to the steel-cased borehole near the target. Time-lapse measurements of horizontal electric field are subsequently made on Earth's surface to map the change in subsurface conductivity due to proppant emplacement. As predicted by 3D numerical modelling, observed differences in electric field values are very small. While these numbers are above the noise floor of electric field sensors, pervasive anthropogenic EM noise and regional-scale magnetotelluric signals make extraction of the differences from the observed time series especially difficult. We present field-acquired data on ambient EM noise in an active oilfield environment and demonstrate techniques for extracting the difference signal due to proppant emplacement. These techniques include classical spectral methods along with estimation of time-domain Green's function by regularized, linear least squares methods.

  19. Investigation of artificial recharge of aquifers in Nebraska

    USGS Publications Warehouse

    Lichtler, William F.; Stannard, David I.; Kouma, Edwin

    1980-01-01

    Progressive declines of ground-water levels in some areas of Nebraska prompted this investigation into the technical feasibility of recharging aquifers through wells, impoundments, pits, and canals. Information gained from a literature search and from preliminary tests was used to design several artificial-recharge experiments in Nebraska from 1977 to 1979. In well experiments, 0.46 billion gallons of water from an aquifer recharged by the Platte River was transported by pipeline and injected through a well into a sand and gravel aquifer near Aurora. Recharge was at about 730 gallons per minute during tests of 6- and 8-months duration. No evidence of clogging of the aquifer due to chemical reactions, air entrainment, or bacteria was detected in either test. In the 6-month test, evidence of clogging due to fine sediment in the recharge water was detected; however, analysis of this test indicated that recharge could have continued for several years before rehabilitation would have become necessary. Results of the 8-month test confirmed results of the earlier test until casing failure in the supply well and subsequent sediment deposition in the recharge well caused rapid water-level rise in the recharge well. In surface-spreading experiments, maximum infiltration rates from 24-foot-diameter ring infiltrometers near Aurora and Tryon were 0.4 and 11 feet per day, respectively. Results indicate that large-scale surface spreading is feasible only where low-permeability layers are absent in the subsurface. Infiltration rates from reuse pits ranged from 0.01 to 1.6 feet per day, indicating highly variable subsurface permeability. Flow measurements in an irrigation canal near Farwell indicate an infiltration rate of 0.37 feet per day. (USGS)

  20. Foot Function, Foot Pain, and Falls in Older Adults: the Framingham Foot Study

    PubMed Central

    Awale, Arunima; Hagedorn, Thomas J.; Dufour, Alyssa B.; Menz, Hylton B.; Casey, Virginia A.; Hannan, Marian T.

    2017-01-01

    Background Although foot pain has been linked to fall risk, contributions of pain severity, foot posture or foot function are unclear. These factors were examined in a cohort of older adults. Objective The purpose of this study was to examine the associations of foot pain, severity of foot pain and measures of foot posture and dynamic foot function with reported falls in a large, well-described cohort of older adults from the Framingham Foot Study. Methods Foot pain, posture and function were collected from Framingham Foot Study participants who were queried about falls over the past year (0, 1, 2+ falls). Logistic regression was used to calculate odds ratios (OR) and 95% confidence intervals (CI) for the relation of falls with foot pain, pain severity, foot posture, and foot function adjusting for covariates. Results Of 1375 participants, mean age was 69y; 57% were female; 21% reported foot pain (40% mild pain, 47% moderate, 13% severe pain). One-third reported falls in past year (1 fall: n=263, 2+ falls: n=152). Foot pain was associated with a 62% increased odds of recurrent falls. Those with moderate and severe foot pain showed increased odds of 2+ falls (OR=1.78, CI 1.06–2.99, and OR = 3.25, CI 1.65–7.48, respectively) compared to no foot pain. Foot function was not associated with falls. Compared to normal foot posture, those with planus foot posture had 78% higher odds of 2+ falls. Conclusion Higher odds of recurrent falls were observed in individuals with foot pain, especially severe foot pain, as well as individuals with planus foot posture, indicating that both foot pain and foot posture may play a role in increasing the risk of falls among older adults. PMID:28482340

  1. Foot Disorders, Foot Posture, and Foot Function: The Framingham Foot Study

    PubMed Central

    Hagedorn, Thomas J.; Dufour, Alyssa B.; Riskowski, Jody L.; Hillstrom, Howard J.; Menz, Hylton B.; Casey, Virginia A.; Hannan, Marian T.

    2013-01-01

    Introduction Foot disorders are common among older adults and may lead to outcomes such as falls and functional limitation. However, the associations of foot posture and foot function to specific foot disorders at the population level remain poorly understood. The purpose of this study was to assess the relation between specific foot disorders, foot posture, and foot function. Methods Participants were from the population-based Framingham Foot Study. Quintiles of the modified arch index and center of pressure excursion index from plantar pressure scans were used to create foot posture and function subgroups. Adjusted odds ratios of having each specific disorder were calculated for foot posture and function subgroups relative to a referent 3 quintiles. Results Pes planus foot posture was associated with increased odds of hammer toes and overlapping toes. Cavus foot posture was not associated with the foot disorders evaluated. Odds of having hallux valgus and overlapping toes were significantly increased in those with pronated foot function, while odds of hallux valgus and hallux rigidus were significantly decreased in those with supinated function. Conclusions Foot posture and foot function were associated with the presence of specific foot disorders. PMID:24040231

  2. Cap rock efficiency of geothermal systems in fold-and-thrust belts: Evidence from paleo-thermal and structural analyses in Rosario de La Frontera geothermal area (NW Argentina)

    NASA Astrophysics Data System (ADS)

    Maffucci, R.; Corrado, S.; Aldega, L.; Bigi, S.; Chiodi, A.; Di Paolo, L.; Giordano, G.; Invernizzi, C.

    2016-12-01

    Cap rock characterization of geothermal systems is often neglected despite fracturing may reduce its efficiency and favours fluid migration. We investigated the siliciclastic cap rock of Rosario de La Frontera geothermal system (NW Argentina) in order to assess its quality as a function of fracture patterns and related thermal alteration. Paleothermal investigations (XRD on fine-grained fraction of sediments, organic matter optical analysis and fluid inclusions on veins) and 1D thermal modelling allowed us to distinguish the thermal fingerprint associated to sedimentary burial from that related to fluid migration. The geothermal system is hosted in a Neogene N-S anticline dissected by high angle NNW- and ENE-striking faults. Its cap rock can be grouped into two quality categories: rocks acting as good insulators, deformed by NNW-SSE and E-W shear fractures, NNE-SSW gypsum- and N-S-striking calcite-filled veins that developed during the initial stage of anticline growth. Maximum paleo-temperatures (< 60 °C) were experienced during deposition to folding phases. rocks acting as bad insulators, deformed by NNW-SSE fault planes and NNW- and WNW-striking sets of fractures associated to late transpressive kinematics. Maximum paleo-temperatures higher than about 115 °C are linked to fluid migration from the reservoir to surface (with a reservoir top at maximum depths of 2.5 km) along fault damage zones. This multi-method approach turned out to be particularly useful to trace the main pathways of hot fluids and can be applied in blind geothermal systems where either subsurface data are scarce or surface thermal anomalies are lacking.

  3. [XPS analysis of beads formed by fuse breaking of electric copper wire].

    PubMed

    Wu, Ying; Meng, Qing-Shan; Wang, Xin-Ming; Gao, Wei; Di, Man

    2010-05-01

    The in-depth composition of beads formed by fuse breaking of the electric copper wire in different circumstances was studied by XPS with Ar+ ion sputtering. In addition, the measured Auger spectra and the calculated Auger parameters were compared for differentiation of the substances of Cu and Cu2O. Corresponding to the sputtering depth, the molten product on a bead induced directly by fuse breaking of the copper wire without cover may be distinguished as three portions: surface layer with a drastic decrease in carbon content; intermediate layer with a gentle change in oxygen content and gradually diminished carbon peak, and consisting of Cu2O; transition layer without Cu2O and with a rapid decrease in oxygen content. While the molten product on a bead formed by fuse breaking of the copper wire after its insulating cover had been burned out may be distinguished as two portions: surface layer with carbon content decreasing quickly; subsurface layer without Cu2O and with carbon and oxygen content decreasing gradually. Thus, it can be seen that there was an obvious interface between the layered surface product and the substrate for the first type of bead, while as to the second type of bead there was no interface. As a result, the presence of Cu2O and the quantitative results can be used to identify the molten product on a bead induced directly by fuse breaking of the copper wire without cover and the molten product on a bead formed by fuse breaking of the cupper wire after its insulating cover had been burned out, as a complementary technique for the judgments of fire cause.

  4. Foot Function, Foot Pain, and Falls in Older Adults: The Framingham Foot Study.

    PubMed

    Awale, Arunima; Hagedorn, Thomas J; Dufour, Alyssa B; Menz, Hylton B; Casey, Virginia A; Hannan, Marian T

    2017-01-01

    Although foot pain has been linked to fall risk, contributions of pain severity, foot posture, or foot function are unclear. These factors were examined in a cohort of older adults. The purpose of this study was to examine the associations of foot pain, severity of foot pain, and measures of foot posture and dynamic foot function with reported falls in a large, well-described cohort of older adults from the Framingham Foot Study. Foot pain, posture, and function were collected from Framingham Foot Study participants who were queried about falls over the past year (0, 1, and ≥2 falls). Logistic regression was used to calculate odds ratios (ORs) and 95% confidence intervals (CIs) for the relation of falls with foot pain, pain severity, foot posture, and foot function adjusting for covariates. The mean age of the 1,375 participants was 69 years; 57% were female, and 21% reported foot pain (40% mild pain, 47% moderate pain, and 13% severe pain). One-third reported falls in the past year (1 fall: n = 263, ≥2 falls: n = 152). Foot pain was associated with a 62% increased odds of recurrent falls. Those with moderate and severe foot pain showed increased odds of ≥2 falls (OR 1.78, CI 1.06-2.99, and OR 3.25, CI 1.65-7.48, respectively) compared to those with no foot pain. Foot function was not associated with falls. Compared to normal foot posture, those with planus foot posture had 78% higher odds of ≥2 falls. Higher odds of recurrent falls were observed in individuals with foot pain, especially severe foot pain, as well as in individuals with planus foot posture, indicating that both foot pain and foot posture may play a role in increasing the risk of falls among older adults. © 2017 S. Karger AG, Basel.

  5. Planus Foot Posture and Pronated Foot Function are Associated with Foot Pain: The Framingham Foot Study

    PubMed Central

    Menz, Hylton B.; Dufour, Alyssa B.; Riskowski, Jody L.; Hillstrom, Howard J.; Hannan, Marian T.

    2014-01-01

    Objective To examine the associations of foot posture and foot function to foot pain. Methods Data were collected on 3,378 members of the Framingham Study who completed foot examinations in 2002–2008. Foot pain (generalized and at six locations) was based on the response to the question “On most days, do you have pain, aching or stiffness in either foot?” Foot posture was categorized as normal, planus or cavus using static pressure measurements of the arch index. Foot function was categorized as normal, pronated or supinated using the center of pressure excursion index from dynamic pressure measurements. Sex-specific multivariate logistic regression models were used to examine the effect of foot posture and function on generalized and location-specific foot pain, adjusting for age and weight. Results Planus foot posture was significantly associated with an increased likelihood of arch pain in men (odds ratio [OR] 1.38, 95% confidence interval [CI] 1.01 – 1.90), while cavus foot posture was protective against ball of foot pain (OR 0.74, 95% CI 0.55 – 1.00) and arch pain (OR 0.64, 95% CI 0.48 – 0.85) in women. Pronated foot function was significantly associated with an increased likelihood of generalized foot pain (OR 1.28, 95% CI 1.04 – 1.56) and heel pain (OR 1.54, 95% CI 1.04 – 2.27) in men, while supinated foot function was protective against hindfoot pain in women (OR 0.74, 95% CI 0.55 – 1.00). Conclusion Planus foot posture and pronated foot function are associated with foot symptoms. Interventions that modify abnormal foot posture and function may therefore have a role in the prevention and treatment of foot pain. PMID:23861176

  6. Quantification of metal loads by tracer injection and synoptic sampling in Daisy Creek and the Stillwater River, Park County, Montana, August 1999

    USGS Publications Warehouse

    Nimick, David A.; Cleasby, Thomas E.

    2001-01-01

    A metal-loading study using tracer-injection and synoptic-sampling methods was conducted in Daisy Creek and a short reach of the Stillwater River during baseflow in August 1999 to quantify the metal inputs from acid rock drainage in the New World Mining District near Yellowstone National Park and to examine the downstream transport of these metals into the Stillwater River. Loads were calculated for many mainstem and inflow sites by combining streamflow determined using the tracer-injection method with concentrations of major ions and metals that were determined in synoptic water-quality samples. Water quality and aquatic habitat in Daisy Creek have been affected adversely by drainage derived from waste rock and adit discharge at the McLaren Mine as well as from natural weathering of pyrite-rich mineralized rock that comprises and surrounds the ore zones. However, the specific sources and transport pathways are not well understood. Knowledge of the main sources and transport pathways of metals and acid can aid resource managers in planning and conducting effective and cost-efficient remediation activities. The metals cadmium, copper, lead, and zinc occur at concentrations that are sufficiently elevated to be potentially lethal to aquatic life in Daisy Creek and to pose a toxicity risk in part of the Stillwater River. Copper is of most concern in Daisy Creek because it occurs at higher concentrations than the other metals. Acidic surface inflows had dissolved concentrations as high as 20.6 micrograms per liter (?g/L) cadmium, 26,900 ?g/L copper, 76.4 ?g/L lead, and 3,000 ?g/L zinc. These inflows resulted in maximum dissolved concentrations in Daisy Creek of 5.8 ?g/L cadmium, 5,790 ?g/L copper, 3.8 ?g/L lead, and 848 ?g/L zinc. Significant copper loading to Daisy Creek occurred only in the upper half of the stream. Sources included subsurface inflow and right-bank (mined side) surface inflows. Copper loads in left-bank (unmined side) surface inflows were negligible. Most (71 percent) of the total copper loading in the study reach occurred along a 341-foot reach near the stream?s headwaters. About 53 percent of the total copper load was contributed by five surface inflows that drain a manganese bog and the southern part of the McLaren Mine. Copper loading from subsurface inflow was substantial, contributing 46 percent of the total dissolved copper load to Daisy Creek. More than half of this subsurface copper loading occurred downstream from the reaches that received significant surface loading. Flow through the shallow subsurface appears to be the main copper-transport pathway from the McLaren Mine and surrounding altered and mineralized bedrock to Daisy Creek during base-flow conditions. Little is known about the source of acid and copper in this subsurface flow. However, possible sources include the mineralized rocks of Fisher Mountain upgradient of the McLaren Mine area, the surficial waste rock at the mine, and the underlying pyritic bedrock.

  7. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Abercrombie, Robert Knox; Richardson, Gregory David; Scudiere, Matthew Bligh

    A pad is disclosed for use in a weighing system for weighing a load. The pad includes a weighing platform, load cells, and foot members. Improvements to the pad reduce or substantially eliminate rotation of one or more of the corner foot members. A flexible foot strap disposed between the corner foot members reduces rotation of the respective foot members about vertical axes through the corner foot members and couples the corner foot members such that rotation of one corner foot member results in substantially the same amount of rotation of the other corner foot member. In a strapless variantmore » one or more fasteners prevents substantially all rotation of a foot member. In a diagonal variant, a foot strap extends between a corner foot member and the weighing platform to reduce rotation of the foot member about a vertical axis through the corner foot member.« less

  8. Foot Pain and Pronated Foot Type are Associated with Self-Reported Mobility Limitations in Older Adults: the Framingham Foot Study

    PubMed Central

    Menz, Hylton B.; Dufour, Alyssa B.; Katz, Patricia; Hannan, Marian T.

    2015-01-01

    Background The foot plays an important role in supporting the body when undertaking weight bearing activities. Aging is associated with an increased prevalence of foot pain and a lowering of the arch of the foot, both of which may impair mobility. Objective To examine the associations of foot pain, foot posture and dynamic foot function with self-reported mobility limitations in community-dwelling older adults. Methods Foot examinations were conducted on 1,860 members of the Framingham Study in 2002–2005. Foot posture was categorized as normal, planus or cavus using static pressure measurements, and foot function was categorized as normal, pronated or supinated using dynamic pressure measurements. Participants were asked whether they had foot pain and any difficulty performing a list of nine weight bearing tasks. Multivariate logistic regression and linear regression models were used to examine the associations of foot pain, posture, function and ability to perform these activities. Results After adjusting for age, sex, height and weight, foot pain was significantly associated with difficulty performing all nine weight bearing activities. Compared to those with normal foot posture and function, participants with planus foot posture were more likely to report difficulty remaining balanced (odds ratio [OR] = 1.40, 95% confidence interval [CI] 1.06 to 1.85; p=0.018) and individuals with pronated foot function were more likely to report difficulty walking across a small room (OR = 2.07, 95% CI 1.02 to 4.22; p=0.045). Foot pain and planus foot posture were associated with an overall mobility limitation score combining performances on each measure. Conclusion Foot pain, planus foot posture and pronated foot function are associated with self-reported difficulty undertaking common weight bearing tasks. Interventions to reduce foot pain and improve foot posture and function may therefore have a role in improving mobility in older adults. PMID:26645379

  9. 76 FR 20974 - Owyhee Hydro, LLC; of Preliminary Permit Application Accepted for Filing and Soliciting Comments...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-04-14

    ...-foot-long, 15.5- foot diameter concrete-lined low-pressure tunnel; (4) a 5,870-foot- long, 15.5-foot-diameter concrete-lined pressure shaft; (5) a 1,815- foot-long, 18.6-foot-diameter concrete-lined tailrace... storage capacity of 8,235-acre-foot; (3) a 1,190-foot-long, 15.5-foot-diameter concrete-lined low-pressure...

  10. 76 FR 12727 - Black Canyon Hydro, LLC; Notice of Preliminary Permit Application Accepted for Filing and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-08

    ... Reservoir with a storage capacity of 9,700-acre-foot; (4) a 3,800-foot-long, 18.7-foot-diameter concrete-lined pressure shaft; (5) a 200-foot-long, 22.4-foot-diameter concrete-lined tailrace; (6) a 280-foot...,700-acre-foot; (4) a 800-foot-long, 20.4-foot-diameter unlined or concrete-lined low-pressure tunnel...

  11. 78 FR 28826 - Village of Morrisville, Vermont; Notice of Application Tendered for Filing With the Commission...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-05-16

    ...- foot-long, 40-foot-wide gatehouse; (4) an 18.0-foot-long, 9.2-foot-high gated intake structure; (5) a... crest elevation of 1,220 feet above mean sea level (msl); (2) a 45- foot-long, 15-foot-high concrete...; (3) a 200-foot-long, 16-foot-high earthen embankment with 2-foot-high wooden wave barriers...

  12. Chemical and valence reconstruction at the surface of SmB6 revealed by means of resonant soft x-ray reflectometry

    NASA Astrophysics Data System (ADS)

    Zabolotnyy, V. B.; Fürsich, K.; Green, R. J.; Lutz, P.; Treiber, K.; Min, Chul-Hee; Dukhnenko, A. V.; Shitsevalova, N. Y.; Filipov, V. B.; Kang, B. Y.; Cho, B. K.; Sutarto, R.; He, Feizhou; Reinert, F.; Inosov, D. S.; Hinkov, V.

    2018-05-01

    Samarium hexaboride (SmB6), a Kondo insulator with mixed valence, has recently attracted much attention as a possible host for correlated topological surface states. Here, we use a combination of x-ray absorption and reflectometry techniques, backed up with a theoretical model for the resonant M4 ,5 absorption edge of Sm and photoemission data, to establish laterally averaged chemical and valence depth profiles at the surface of SmB6. We show that upon cleaving, the highly polar (001) surface of SmB6 undergoes substantial chemical and valence reconstruction, resulting in boron termination and a Sm3 + dominated subsurface region. Whereas at room temperature, the reconstruction occurs on a timescale of less than 2 h, it takes about 24 h below 50 K. The boron termination is eventually established, irrespective of the initial termination. Our findings reconcile earlier depth resolved photoemission and scanning tunneling spectroscopy studies performed at different temperatures and are important for better control of surface states in this system.

  13. Parametric Analysis of the feasibility of low-temperature geothermal heat recovery in sedimentary basins

    NASA Astrophysics Data System (ADS)

    Tomac, I.; Caulk, R.

    2016-12-01

    The current study explored the feasibility of heat recovery through the installation of heat exchangers in abandoned oil and gas wells. Finite Element Methods (FEM) were employed to determine the effects of various site specific parameters on production fluid temperature. Specifically, the study parameterized depth of well, subsurface temperature gradient, sedimentary rock conductivity, and flow rate. Results show that greater well depth is associated with greater heat flow, with the greatest returns occurring between depths of 1.5 km and 7 km. Beyond 7 km, the rate of return decreases due to a non-linear increase of heat flow combined with a continued linear increase of pumping cost. One cause for the drop of heat flow was the loss of heat as the fluid travels from depth to the surface. Further analyses demonstrated the benefit of an alternative heat exchanger configuration characterized by thermally insulated sections of the upward heat exchanger. These simulations predict production fluid temperature gains between 5 - 10 oC, which may be suitable for geothermal heat pump applications.

  14. Self-propelled instrumented deep drilling system

    NASA Technical Reports Server (NTRS)

    Myrick, Thomas M. (Inventor); Gorevan, Stephen (Inventor)

    2006-01-01

    An autonomous subsurface drilling device has spaced-apart forward and rearward feet sections coupled to an axial thruster mechanism between them to operate using an inchworm method of mobility. In one embodiment, forward and rearward drill sections are carried on forward and rearward feet sections for drilling into material in the borehole in both forward and rearward directions, to allow the device to maneuver in any direction underground. In another embodiment, a front drill section has a drill head for cutting into the borehole and conveying cuttings through a center spine tube to an on-board depository for the cuttings. The feet sections of the device employ a foot scroll drive unit to provide radial thrust and synchronous motion to the feet for gripping the borehole wall. The axial thrust mechanism has a tandem set of thrusters in which the second thruster is used to provide the thrust needed for drilling, but not walking. A steering mechanism composed of concentric inner and outer eccentric rings provided with the rearward feet section allow small corrections in both direction and magnitude to the drilling direction as drilling commences.

  15. Airport cleanup rises above problems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pressly, N.; Lucas, B.; Frumer, B.

    Engineers used a treatment combination to improve the in-situ bioremediation system`s efficiency in removing underground fuel leaks at JFK Airport. John F. Kennedy International Airport, in New York City, on Jamaica Bay, has an above-ground storage capacity of about 32 million gallons of jet fuel, which flow through about 50 miles of high-pressure underground pipe to the central terminal area. EAch terminal`s fuel hydrant system was the major source os subsurface contamination at the site. The site is covered by 1 to 1.5 feet of reinforced concrete pavement. Liquid phase jet fuel (free product) was measured on the water tablemore » with true thickness ranging from less than 1 inch to 1 foot. After analysis of core samples, contamination was found adsorbed to the soil with maximum levels at the water table. This article describes the clean up, covering the following topics: microbial conditions during system operation; above-ground treatment challenges: free product emulsification, presence of biomass; evaluation of enhancements: dissolved air floatation, coagulation and flocculation, retention time adjustments; conclusions.« less

  16. Numerical investigations of microtopographic influence on the near surface thermal regime and thermokarst development in ice wedge polygons

    NASA Astrophysics Data System (ADS)

    Abolt, C.; Young, M.; Atchley, A. L.; Harp, D. R.

    2017-12-01

    Permafrost degradation in ice wedge polygon terrain has accelerated in the last three decades, resulting in drastic changes to tundra hydrology which may impact rates of soil organic carbon mobilization. The goal of this research is to determine to what extent the near surface thermal regime, and hence the vulnerability of the upper permafrost, may be controlled by surface topography in ice wedge polygons. The central hypothesis is that energy is preferentially transferred into the polygon subsurface in summer at low, wet zones (such as low-centered polygon centers and troughs), then released to the atmosphere in winter through elevated zones (such as rims) that are less insulated by snowpack. Disturbance to the approximate balance between these seasonal energy fluxes may help explain the onset and development of thermokarst. In this work, we present a numerical model of thermal hydrology in a low-centered polygon near Prudhoe Bay, Alaska, constructed within the Advanced Terrestrial Simulator, a state of the art code that couples a meteorologically driven surface energy balance with equations for surface and subsurface conservation of mass and energy. The model is calibrated against a year of daily ground temperature observations throughout the polygon and used to quantify meter-scale zonation in the subsurface thermal budget. The amount of relief in the rims and the trough of the simulated polygon is then manipulated, and simulations are repeated including a pulse of one warm year, to explore the extent to which topography may influence the response of permafrost to increased air temperatures. Results suggest that nearly 25% of energy entering the ground at the polygon center during summer may be released back to the atmosphere through the rims in winter, producing a modest effect on active layer thickness throughout the polygon. Simulated polygons with deeper, wetter troughs have only marginally thicker active layers than other polygons in average years, but are the most vulnerable to additional permafrost degradation during warm summers. The results confirm and expand upon current conceptual understanding of positive feedbacks during thermokarst development, and are compatible with historical observations indicating that ice wedge degradation tends to occur in discrete pulses, rather than as a gradual process.

  17. 77 FR 53878 - L.S. Starrett Company; Notice of Application Tendered for Filing With the Commission and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-09-04

    ... 385.2001(a)(1)(iii) and the instructions on the Commission's Web site http://www.ferc.gov/docs-filing... conduit equipped with a 7-foot-high, 7-foot-wide gate; (e) a 16-foot-wide, 4-foot-deep, 200-foot-long... generating unit; (d) and a 14- foot-wide, 9-foot-deep, 100-foot-long tailrace (e) six 900-foot-long, 600 volt...

  18. Foot index: is it a tool for sex determination?

    PubMed

    Moudgil, Rohan; Kaur, Ramneet; Menezes, Ritesh G; Kanchan, Tanuj; Garg, Rakesh K

    2008-05-01

    Identification of an individual is of paramount importance in forensic investigations. The dimensions of the foot can be used for the determination of sex and stature of an individual in forensic investigations. No systematic studies are available on the determination of sex from foot measurements of North Indians. Therefore, foot index is derived to determine the sex of an individual in a single community of North India. The foot index for both genders is derived by dividing the foot breadth by foot length and multiplying it by hundred. In the present investigation, the foot index is found to be slightly higher in females in the right foot and males in the left foot. The study suggests that although foot length and foot breadth show significant sex differences, sex determination cannot be made conclusively from the foot index.

  19. Biodegradation performance of environmentally-friendly insulating oil

    NASA Astrophysics Data System (ADS)

    Yang, Jun; He, Yan; Cai, Shengwei; Chen, Cheng; Wen, Gang; Wang, Feipeng; Fan, Fan; Wan, Chunxiang; Wu, Liya; Liu, Ruitong

    2018-02-01

    In this paper, biodegradation performance of rapeseed insulating oil (RDB) and FR3 insulating oil (FR3) was studied by means of ready biodegradation method which was performed with Organization for Economic Co-operation and Development (OECD) 301B. For comparison, the biodegradation behaviour of 25# mineral insulating oil was also characterized with the same method. The testing results shown that the biodegradation degree of rapeseed insulating oil, FR3 insulating oil and 25# mineral insulating oil was 95.8%, 98.9% and 38.4% respectively. Following the “new chemical risk assessment guidelines” (HJ/T 154 - 2004), which illustrates the methods used to identify and assess the process safety hazards inherent. The guidelines can draw that the two vegetable insulating oils, i.e. rapeseed insulating oil and FR3 insulating oil are easily biodegradable. Therefore, the both can be classified as environmentally-friendly insulating oil. As expected, 25# mineral insulating oil is hardly biodegradable. The main reason is that 25# mineral insulating oil consists of isoalkanes, cyclanes and a few arenes, which has few unsaturated bonds. Biodegradation of rapeseed insulating oil and FR3 insulating oil also remain some difference. Biodegradation mechanism of vegetable insulating oil was revealed from the perspective of hydrolysis kinetics.

  20. Taiwanese adult foot shape classification using 3D scanning data.

    PubMed

    Lee, Yu-Chi; Wang, Mao-Jiun

    2015-01-01

    This study classifies the foot shapes of Taiwanese using 3D foot scanning data from 2000 males and 1000 females. Nine foot dimensions relative to foot length and absolute measures in the common foot length categories were applied to compare the gender differences. Using foot breadth in % foot length (% FL), ball of foot length in % FL and arch height in % FL as feature parameters, three foot shape types for males and females can be classified. Significant gender differences were found in seven of the nine foot dimensions. Females had greater ball of foot length than males (0.2% FL). When comparing feet of the same foot length, males had greater breadth, girth and height dimensions than females, except for toe height. In addition, ethnic differences in foot shape were also observed. The findings can provide very useful information for building gender-specific shoe lasts and designing footwear insoles. 3D foot scanning data of 2000 males and 1000 females were classified into three different footshapes for males and females, respectively. Gender and ethnic differences on foot shape were also compared. The finding scan provide very useful information for gender-specific shoe last design and footwear production.

  1. Modelling foot height and foot shape-related dimensions.

    PubMed

    Xiong, Shuping; Goonetilleke, Ravindra S; Witana, Channa P; Lee Au, Emily Yim

    2008-08-01

    The application of foot anthropometry to design good-fitting footwear has been difficult due to the lack of generalised models. This study seeks to model foot dimensions so that the characteristic shapes of feet, especially in the midfoot region, can be understood. Fifty Hong Kong Chinese adults (26 males and 24 females) participated in this study. Their foot lengths, foot widths, ball girths and foot heights were measured and then evaluated using mathematical models. The results showed that there were no significant allometry (p > 0.05) effects of foot length on ball girth and foot width. Foot height showed no direct relationship with foot length. However, a normalisation with respect to foot length and foot height resulted in a significant relationship for both males and females with R(2) greater than 0.97. Due to the lack of a direct relationship between foot height and foot length, the current practice of grading shoes with a constant increase in height or proportionate scaling in response to foot length is less than ideal. The results when validated with other populations can be a significant way forward in the design of footwear that has an improved fit in the height dimension.

  2. Evaluation of nutrient removal efficiency and microbial enzyme activity in a baffled subsurface-flow constructed wetland system

    Treesearch

    Lihua Cui; Ying Ouyang; Wenjie Gu; Weozhi Yang; Qiaoling Xu

    2013-01-01

    In this study, the enzyme activities and their relationships to domestic wastewater purification are investigated in four different types of subsurface-flow constructed wetlands (CWs), namely the traditional horizontal subsurface-flow, horizontal baffled subsurface-flow, vertical baffled subsurface-flow, and composite baffled subsurface-flow CWs. Results showed that...

  3. Microsphere insulation systems

    NASA Technical Reports Server (NTRS)

    Allen, Mark S. (Inventor); Willen, Gary S. (Inventor); Mohling, Robert A. (Inventor)

    2005-01-01

    A new insulation system is provided that contains microspheres. This insulation system can be used to provide insulated panels and clamshells, and to insulate annular spaces around objects used to transfer, store, or transport cryogens and other temperature-sensitive materials. This insulation system provides better performance with reduced maintenance than current insulation systems.

  4. The influence of foot orthoses on foot mobility magnitude and arch height index in adults with flexible flat feet.

    PubMed

    Sheykhi-Dolagh, Roghaye; Saeedi, Hassan; Farahmand, Behshid; Kamyab, Mojtaba; Kamali, Mohammad; Gholizadeh, Hossein; Derayatifar, Amir A; Curran, Sarah

    2015-06-01

    Flexible flat foot is described as a reduction in the height of the medial longitudinal arch and may occur from abnormal foot pronation. A foot orthosis is thought to modify and control excessive pronation and improve arch height. To compare the immediate effect of three types of orthoses on foot mobility and the arch height index in subjects with flexible flat feet. A quasi-experimental study. The dorsal arch height, midfoot width, foot mobility and arch height index were assessed in 20 participants with flexible flat feet (mean age = 23.2 ± 3 years) for three different foot orthosis conditions: soft, semi-rigid and rigid University of California Biomechanics Laboratory (UCBL). Maximum midfoot width at 90% with arch mobility in the coronal plane was shown in the semi-rigid orthosis condition. The semi-rigid orthosis resulted in the highest mean foot mobility in 90% of weight bearing, and the rigid orthosis (UCBL) had the lowest mean foot mobility. The soft orthosis resulted in foot mobility between that of the rigid and the semi-rigid orthosis. UCBL orthosis showed the highest arch height index, and the semi-rigid orthosis showed the lowest mean arch height index. Due to its rigid structure and long medial-lateral walls, the UCBL orthosis appears to limit foot mobility. Therefore, it is necessary to make an orthosis that facilitates foot mobility in the normal range of the foot arch. Future studies should address the dynamic mobility of the foot with using various types of foot orthoses. Although there are many studies focussed on flat foot and the use of foot orthoses, the mechanism of action is still unclear. This study explored foot mobility and the influence of foot orthoses and showed that a more rigid foot orthosis should be selected based on foot mobility. © The International Society for Prosthetics and Orthotics 2014.

  5. Comparing 3D foot scanning with conventional measurement methods.

    PubMed

    Lee, Yu-Chi; Lin, Gloria; Wang, Mao-Jiun J

    2014-01-01

    Foot dimension information on different user groups is important for footwear design and clinical applications. Foot dimension data collected using different measurement methods presents accuracy problems. This study compared the precision and accuracy of the 3D foot scanning method with conventional foot dimension measurement methods including the digital caliper, ink footprint and digital footprint. Six commonly used foot dimensions, i.e. foot length, ball of foot length, outside ball of foot length, foot breadth diagonal, foot breadth horizontal and heel breadth were measured from 130 males and females using four foot measurement methods. Two-way ANOVA was performed to evaluate the sex and method effect on the measured foot dimensions. In addition, the mean absolute difference values and intra-class correlation coefficients (ICCs) were used for precision and accuracy evaluation. The results were also compared with the ISO 20685 criteria. The participant's sex and the measurement method were found (p < 0.05) to exert significant effects on the measured six foot dimensions. The precision of the 3D scanning measurement method with mean absolute difference values between 0.73 to 1.50 mm showed the best performance among the four measurement methods. The 3D scanning measurements showed better measurement accuracy performance than the other methods (mean absolute difference was 0.6 to 4.3 mm), except for measuring outside ball of foot length and foot breadth horizontal. The ICCs for all six foot dimension measurements among the four measurement methods were within the 0.61 to 0.98 range. Overall, the 3D foot scanner is recommended for collecting foot anthropometric data because it has relatively higher precision, accuracy and robustness. This finding suggests that when comparing foot anthropometric data among different references, it is important to consider the differences caused by the different measurement methods.

  6. Effects of ankle-foot orthoses on mediolateral foot-placement ability during post-stroke gait.

    PubMed

    Zissimopoulos, Angelika; Fatone, Stefania; Gard, Steven

    2015-10-01

    Accurate and precise mediolateral foot placement is important for balance during gait, but is impaired post stroke. Mediolateral foot placement may be improved with ankle-foot orthosis use. The purpose of this study was to determine whether an ankle-foot orthosis improves mediolateral foot-placement ability during post-stroke ambulation. Crossover trial with randomized order of conditions tested. The accuracy and precision of mediolateral foot placement was quantified while subjects targeted four different randomized step widths. Subjects were tested with and without their regular non-rigid ankle-foot orthosis in two separate visits (order randomized). While ankle-foot orthosis use corrected foot and ankle alignment (i.e. significantly decreased mid-swing plantar flexion, p = 0.000), effects of ankle-foot orthosis use on hip hiking (p = 0.545), circumduction (p = 0.179), coronal plane hip range of motion (p = 0.06), and mediolateral foot-placement ability (p = 0.537) were not significant. While ankle-foot orthosis-mediated equinovarus correction of the affected foot and ankle was not associated with improved biomechanics of walking (i.e. proximal ipsilateral hip kinematics or mediolateral foot-placement ability), it may affect other aspects of balance that were not tested in this study (e.g. proprioception, cerebellar, vestibular, and cognitive mechanisms). Studies that investigate the effect of ankle-foot orthosis on gait can help advance stroke rehabilitation by documenting the specific gait benefits of ankle-foot orthosis use. In this study, we investigated the effect of ankle-foot orthosis use on mediolateral foot-placement ability, an aspect of gait important for maintaining balance. © The International Society for Prosthetics and Orthotics 2014.

  7. Mussel adhesion – essential footwork

    PubMed Central

    2017-01-01

    ABSTRACT Robust adhesion to wet, salt-encrusted, corroded and slimy surfaces has been an essential adaptation in the life histories of sessile marine organisms for hundreds of millions of years, but it remains a major impasse for technology. Mussel adhesion has served as one of many model systems providing a fundamental understanding of what is required for attachment to wet surfaces. Most polymer engineers have focused on the use of 3,4-dihydroxyphenyl-l-alanine (Dopa), a peculiar but abundant catecholic amino acid in mussel adhesive proteins. The premise of this Review is that although Dopa does have the potential for diverse cohesive and adhesive interactions, these will be difficult to achieve in synthetic homologs without a deeper knowledge of mussel biology; that is, how, at different length and time scales, mussels regulate the reactivity of their adhesive proteins. To deposit adhesive proteins onto target surfaces, the mussel foot creates an insulated reaction chamber with extreme reaction conditions such as low pH, low ionic strength and high reducing poise. These conditions enable adhesive proteins to undergo controlled fluid–fluid phase separation, surface adsorption and spreading, microstructure formation and, finally, solidification. PMID:28202646

  8. KSC-2009-6794

    NASA Image and Video Library

    2009-12-11

    CAPE CANAVERAL, Fla. - Concrete is poured into the trenches that will provide the foundation for the walls of the Propellants North Administrative and Maintenance Facility in Launch Complex 39 at NASA's Kennedy Space Center in Florida. A tilt-up construction method is being used to erect a THERMOMASS concrete wall insulation system for the facility's walls. The facility will have a two-story administrative building to house managers, mechanics and technicians who fuel spacecraft at Kennedy adjacent to an 1,800-square-foot single-story shop to store cryogenic fuel transfer equipment. The new facility will feature high-efficiency roofs and walls, “Cool Dry Quiet” air conditioning with energy recovery technology, efficient lighting, and other sustainable features. The facility is striving to qualify for the U.S. Green Building Council’s Leadership in Energy and Environmental Design, or LEED, Platinum certification. If successful, Propellants North will be the first Kennedy facility to achieve this highest of LEED ratings after it is completed in the summer of 2010. The facility was designed for NASA by Jones Edmunds and Associates. Photo credit: NASA/Jim Grossmann

  9. Aerothermal performance and structural integrity of a Rene 41 thermal protection system at Mach 6.6

    NASA Technical Reports Server (NTRS)

    Deveikis, W. D.; Miserentino, R.; Weinstein, I.; Shideler, J. L.

    1975-01-01

    A flightweight panel based on a metallic thermal-protection-system concept for hypersonic and reentry vehicles was subjected repeatedly to thermal cycling by quartz-lamp radiant heating using a thermal history representative of a reentry heat pulse and to aerodynamic heating at heating rates required to sustain a surface temperature of 1089 K (1960 R). The panel consisted of a corrugated heat shield and support members of 0.05-cm (0.02-in.) thick Rene 41 of riveted construction and 5.08-cm (2-in.) thick silica fibrous insulation packages covered by Rene 41 foil and inconel screening. All tests were conducted in the Langley 8-foot high-temperature structures tunnel with the heat shield corrugations alined in the stream direction. The panel sustained 5.33 hr of intermittent radiant heating and 6.5 min of intermittent aerodynamic heating of up to 1-min duration for differential pressures up to 6.2 kPa (0.9 psi) with no apparent degradation of thermal or structural integrity, as indicated by temperature distributions and results from load deflection tests and vibration surveys of natural frequencies.

  10. Foot Complications in a Representative Australian Inpatient Population

    PubMed Central

    Hurn, Sheree E.; Kamp, Maarten C.; Ng, Vanessa; Thomas, Courtney; Jen, Scott; Wills, Jude; Kinnear, Ewan M.; d'Emden, Michael C.; Reed, Lloyd F.

    2017-01-01

    We investigated the prevalence and factors independently associated with foot complications in a representative inpatient population (adults admitted for any reason with and without diabetes). We analysed data from the Foot disease in inpatients study, a sample of 733 representative inpatients. Previous amputation, previous foot ulceration, peripheral arterial disease (PAD), peripheral neuropathy (PN), and foot deformity were the foot complications assessed. Sociodemographic, medical, and foot treatment history were collected. Overall, 46.0% had a foot complication with 23.9% having multiple; those with diabetes had higher prevalence of foot complications than those without diabetes (p < 0.01). Previous amputation (4.1%) was independently associated with previous foot ulceration, foot deformity, cerebrovascular accident, and past surgeon treatment (p < 0.01). Previous foot ulceration (9.8%) was associated with PN, PAD, past podiatry, and past nurse treatment (p < 0.02). PAD (21.0%) was associated with older age, males, indigenous people, cancer, PN, and past surgeon treatment (p < 0.02). PN (22.0%) was associated with older age, diabetes, mobility impairment, and PAD (p < 0.05). Foot deformity (22.4%) was associated with older age, mobility impairment, past podiatry treatment, and PN (p < 0.01). Nearly half of all inpatients had a foot complication. Those with foot complications were older, male, indigenous, had diabetes, cerebrovascular accident, mobility impairment, and other foot complications or past foot treatment. PMID:29164152

  11. 75 FR 66083 - Iron Mask Hydro, LLC; Notice of Preliminary Permit Application Accepted for Filing and Soliciting...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-10-27

    ... following: (1) A 225-foot- high, 1,795-foot-long upper dam made of either zoned earth and rockfill or concrete-face earth and rockfill; (2) a 50-foot-high, 950-foot-long earth-filled upper saddle dike A; (3) a 20-foot-high, 400-foot-long earth-filled upper saddle dike B; (4) a 40-foot-high, 6,559-foot-long...

  12. 78 FR 33406 - Clean River Power MR-1, LLC, Clean River Power MR-2, LLC, Clean River Power MR-3, LLC, Clean...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-06-04

    ..., 52-foot-high, 80-foot-wide intake structure with trash racks containing 2-inch clear bar spacing; (2... following new facilities: (1) A 37-foot-long, 23-foot-high, 80-foot- wide intake structure with trash racks... new facilities: (1) A 37- foot-long, 52-foot-high, 88-foot-wide intake structure with trash racks...

  13. 77 FR 65676 - L.S. Starrett Company; Notice of Application Accepted for Filing With the Commission, Intent To...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-10-30

    ...)(1)(iii) and the instructions on the Commission's Web site http://www.ferc.gov/docs-filing/efiling... conduit equipped with a 7-foot-high, 7-foot-wide gate; (e) a 16-foot-wide, 4-foot-deep, 200-foot-long... a 198 kW turbine generating unit; (d) a 14-foot-wide, 9-foot-deep, 100-foot-long tailrace; and (e...

  14. Effect of Custom-Molded Foot Orthoses on Foot Pain and Balance in Children With Symptomatic Flexible Flat Feet

    PubMed Central

    Lee, Hong-Jae; Lim, Kil-Byung; Yoo, JeeHyun; Yun, Hyun-Ju; Jeong, Tae-Ho

    2015-01-01

    Objective To evaluate the effect of custom-molded foot orthoses on foot pain and balance in children with symptomatic flexible flat foot 1 month and 3 months after fitting foot orthosis. Method A total of 24 children over 6 years old with flexible flat feet and foot pain for at least 6 months were recruited for this study. Their resting calcaneal stance position and calcaneal pitch angle were measured. Individual custom-molded rigid foot orthoses were prescribed using inverted orthotic technique to control foot overpronation. Pain questionnaire was used to obtain pain sites, degree, and frequency. Balancing ability was determined using computerized posturography. These evaluations were performed prior to custom-molded foot orthoses, 1 month, and 3 months after fitting foot orthoses. Result Of 24 children with symptomatic flexible flat feet recruited for this study, 20 completed the study. Significant (p<0.001) improvements in pain degree and frequency were noted after 1 and 3 months of custom-molded foot orthoses. In addition, significant (p<0.05) improvement in balancing ability was found after 3 months of custom-molded foot orthoses. Conclusion Short-term use of custom-molded foot orthoses significantly improved foot pain and balancing ability in children with symptomatic flexible flat foot. PMID:26798604

  15. Cavus Foot (High-Arched Foot)

    MedlinePlus

    ... the heel tilting inward, which can lead to ankle sprains Some people with cavus foot may also experience foot drop, a weakness of the muscles in the foot and ankle that results in dragging the foot when taking ...

  16. 75 FR 78234 - Lock+TM

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-12-15

    ... project (Project No. 13780-000) would consist of: (1) An 85-foot-long, 100-foot-wide, 14-foot-deep excavated power canal; (2) a 95-foot-long, 100-foot-wide, 10-foot-deep excavated tailrace; (3) a 100-foot...)(iii) and the instructions on the Commission's Web site http://www.ferc.gov/docs-filing/efiling.asp...

  17. The effect of foot arch on plantar pressure distribution during standing.

    PubMed

    Periyasamy, R; Anand, Sneh

    2013-07-01

    The aim of this study was to explore how foot type affects plantar pressure distribution during standing. In this study, 32 healthy subjects voluntarily participated and the subject feet were classified as: normal feet (n = 23), flat feet (n = 14) and high arch feet (n = 27) according to arch index (AI) values obtained from foot pressure intensity image analysis. Foot pressure intensity images were acquired by a pedopowergraph system to obtain a foot pressure distribution parameter-power ratio (PR) during standing in eight different regions of the foot. Contact area and mean PR were analysed in hind foot, mid-foot and fore foot regions. One-way analysis of variance was used to determine statistical differences between groups. The contact area and mean PR value beneath the mid-foot was significantly increased in the low arch foot when compared to the normal arch foot and high arch foot (p < 0.001) in both feet. However, subjects with low-arch feet had significantly higher body mass index (BMI) compared to subjects with high-arch feet (p < 0.05) and subjects with normal arch feet (p < 0.05) in both feet. In addition, subjects with low-arch feet had significant differences in arch index (AI) value as compared to subjects with high-arch feet (p < 0.001) and subjects with normal arch feet (p < 0.05) in both feet. Mean mid-foot PR value were positively (r = 0.54) correlated with increased arch index (AI) value. A significant (p < 0.05) change was obtained in PR value beneath the mid-foot of low arch feet when compared with other groups in both feet. The findings suggest that there is an increased mid-foot PR value in the low arch foot as compared to the normal arch foot and high arch foot during standing. Therefore, individuals with low arch feet could be at high risk for mid-foot collapse and Charcot foot problems, indicating that foot type should be assessed when determining an individual's risk for foot injury.

  18. 3D foot shape generation from 2D information.

    PubMed

    Luximon, Ameersing; Goonetilleke, Ravindra S; Zhang, Ming

    2005-05-15

    Two methods to generate an individual 3D foot shape from 2D information are proposed. A standard foot shape was first generated and then scaled based on known 2D information. In the first method, the foot outline and the foot height were used, and in the second, the foot outline and the foot profile were used. The models were developed using 40 participants and then validated using a different set of 40 participants. Results show that each individual foot shape can be predicted within a mean absolute error of 1.36 mm for the left foot and 1.37 mm for the right foot using the first method, and within a mean absolute error of 1.02 mm for the left foot and 1.02 mm for the right foot using the second method. The second method shows somewhat improved accuracy even though it requires two images. Both the methods are relatively cheaper than using a scanner to determine the 3D foot shape for custom footwear design.

  19. Direct inpatient burden caused by foot-related conditions: a multisite point-prevalence study

    PubMed Central

    Lazzarini, Peter A; Hurn, Sheree E; Kuys, Suzanne S; Kamp, Maarten C; Ng, Vanessa; Thomas, Courtney; Jen, Scott; Kinnear, Ewan M; d'Emden, Michael C; Reed, Lloyd

    2016-01-01

    Objective The aims of this point-prevalence study were to investigate a representative inpatient population to determine the prevalence of people admitted to hospital for the reason of a foot-related condition, and identify associated independent factors. Methods Participants were adult inpatients in 5 different representative hospitals, admitted for any reason on the day of data collection. Maternity, mental health and cognitively impaired inpatients were excluded. Participants were surveyed on a range of self-reported demographic, social determinant, medical history, foot disease history, self-care, footwear, past foot treatment prior to hospitalisation and reason for admission variables. Physical examinations were performed to clinically diagnose a range of foot disease and foot risk factor variables. Independent factors associated with being admitted to hospital for the primary or secondary reason of a foot-related condition were analysed using multivariate logistic regression. Results Overall, 733 participants were included; mean (SD) age 62 (19) years, male 55.8%. Foot-related conditions were the primary reason for admission in 54 participants (7.4% (95% CI 5.7% to 9.5%)); 36 for foot disease (4.9%), 15 foot trauma (2.1%). Being admitted for the primary reason of a foot-related condition was independently associated with foot infection, critical peripheral arterial disease, foot trauma and past foot treatment by a general practitioner and surgeon (p<0.01). Foot-related conditions were a secondary reason for admission in 28 participants (3.8% (2.6% to 5.6%)), and were independently associated with diabetes and current foot ulcer (p<0.01). Conclusions This study, the first in a representative inpatient population, suggests the direct inpatient burden caused by foot-related conditions is significantly higher than previously appreciated. Findings indicate 1 in every 13 inpatients was primarily admitted because of a foot-related condition with most due to foot disease or foot trauma. Future strategies are recommended to investigate and intervene in the considerable inpatient burden caused by foot-related conditions. PMID:27324710

  20. Foot health and self-care activities of older people in home care.

    PubMed

    Stolt, Minna; Suhonen, Riitta; Puukka, Pauli; Viitanen, Matti; Voutilainen, Päivi; Leino-Kilpi, Helena

    2012-11-01

    To assess the foot health of older people and their self-care activities in home care. The ultimate goal is to prevent foot problems in older people and to develop the assessment skills of nurses working in home care. Foot health problems are one reason why older people seek home care services. These problems are prevalent in older people, and they can impair performance of daily activities and threaten functional ability. However, studies in this field have concentrated on foot problems related to specific diseases. Non-disease-related research on foot health from the preventative perspective is lacking. A descriptive explorative design was used. The foot health of older people was assessed by visiting home nurses with the Foot Health Assessment Instrument, and older people's foot self-care activities were evaluated with the Foot Self-Care Activities Structured Interview in 2010. The data were analysed statistically. Older people in home care have multiple foot health problems. The most prevalent problems were oedema, dry skin, thickened and discoloured toenails and hallux valgus. Caring for one's feet was a problem for many older people. Older people's foot health needs to be assessed regularly to recognise foot health and self-care problems. Health care professionals have a vital role in preventing, recognising and caring for foot health in older people. The foot health of older people needs to be improved by supporting older people in foot self-care and developing preventive nursing interventions. Regular foot health assessments and their documentation are crucial in preventing serious foot problems in older people. Moreover, multiprofessional collaboration is important to promote foot health in older people. © 2012 Blackwell Publishing Ltd.

  1. Foot Type Biomechanics Part 1: Structure and Function of the Asymptomatic Foot

    PubMed Central

    Hillstrom, Howard J.; Song, Jinsup; Kraszewski, Andrew P.; Hafer, Jocelyn F.; Mootanah, Rajshree; Dufour, Alyssa B.; PT, Betty (Shingpui) Chow; Deland, Jonathan T.

    2012-01-01

    Background Differences in foot structure are thought to be associated with differences in foot function during movement. Many foot pathologies are of a biomechanical nature and often associated with foot type. Fundamental to the understanding of foot pathomechanics is the question: do different foot types have distinctly different structure and function? Aim To determine if objective measures of foot structure and function differ between planus, rectus and cavus foot types in asymptomatic individuals. Methods Sixty-one asymptomatic healthy adults between 18 and 77 years old, that had the same foot type bilaterally (44 planus feet, 54 rectus feet, and 24 cavus feet), were recruited. Structural and functional measurements were taken using custom equipment, an emed-x plantar pressure measuring device, a GaitMatII gait pattern measurement system, and a goniometer. Generalized Estimation Equation modeling was employed to determine if each dependent variable of foot structure and function was significantly different across foot type while accounting for potential dependencies between sides. Post hoc testing was performed to assess pairwise comparisons. Results Several measures of foot structure (malleolar valgus index and arch height index) were significantly different between foot types. Gait pattern parameters were invariant across foot types. Peak pressure, maximum force, pressure-time-integral, force-time-integral and contact area were significantly different in several medial forefoot and arch locations between foot types. Planus feet exhibited significantly different center of pressure excursion indices compared to rectus and cavus feet. Conclusions Planus, rectus and cavus feet exhibited significantly different measures of foot structure and function. PMID:23107625

  2. Comparison of plantar pressure distribution in CAD-CAM and prefabricated foot orthoses in patients with flexible flatfeet.

    PubMed

    Khodaei, Banafsheh; Saeedi, Hassan; Jalali, Maryam; Farzadi, Maede; Norouzi, Ehsan

    2017-12-01

    The effect of foot orthoses on plantar pressure distribution has been proven by researchers but there are some controversies about advantages of custom-made foot orthoses to less expensive prefabricated foot orthoses. Nineteen flatfeet adults between 18 and 45 participated in this study. CAD-CAM foot orthoses were made for these patients according to their foot scan. Prefabricated foot orthoses were prepared according to their foot size. Plantar pressure, force and contact area were measured using pedar ® -x in-shoe system wearing shoe alone, wearing CAD-CAM foot orthoses and wearing prefabricated foot orthoses. Repeated measures ANOVA model with post-hoc, Bonferroni comparison were used to test differences. CAD-CAM and prefabricated foot orthoses both decreased pressure and force under 2nd, 3-5 metatarsal and heel regions comparing to shoe alone condition. CAD-CAM foot orthosis increased pressure under lateral toe region in comparison to shoe alone and prefabricated foot orthosis. Both foot orthoses increased pressure and contact area in medial midfoot region comparing to shoe alone condition. Increased forces were seen at hallux and lateral toes by prefabricated foot orthoses in comparison with CAD-CAM foot orthoses and control condition, respectively. According to the results, both foot orthoses could decrease the pressure under heel and metatarsal area. It seems that the special design of CAD-CAM foot orthoses could not make great differences in plantar pressure distribution in this sample. Further research is required to determine whether these results are associated with different scan systems or design software. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. Foot type biomechanics part 1: structure and function of the asymptomatic foot.

    PubMed

    Hillstrom, Howard J; Song, Jinsup; Kraszewski, Andrew P; Hafer, Jocelyn F; Mootanah, Rajshree; Dufour, Alyssa B; Chow, Betty Shingpui; Deland, Jonathan T

    2013-03-01

    Differences in foot structure are thought to be associated with differences in foot function during movement. Many foot pathologies are of a biomechanical nature and often associated with foot type. Fundamental to the understanding of foot pathomechanics is the question: do different foot types have distinctly different structure and function? To determine if objective measures of foot structure and function differ between planus, rectus and cavus foot types in asymptomatic individuals. Sixty-one asymptomatic healthy adults between 18 and 77 years old, that had the same foot type bilaterally (44 planus feet, 54 rectus feet, and 24 cavus feet), were recruited. Structural and functional measurements were taken using custom equipment, an emed-x plantar pressure measuring device, a GaitMat II gait pattern measurement system, and a goniometer. Generalized Estimation Equation modeling was employed to determine if each dependent variable of foot structure and function was significantly different across foot type while accounting for potential dependencies between sides. Post hoc testing was performed to assess pair wise comparisons. Several measures of foot structure (malleolar valgus index and arch height index) were significantly different between foot types. Gait pattern parameters were invariant across foot types. Peak pressure, maximum force, pressure-time-integral, force-time-integral and contact area were significantly different in several medial forefoot and arch locations between foot types. Planus feet exhibited significantly different center of pressure excursion indices compared to rectus and cavus feet. Planus, rectus and cavus feet exhibited significantly different measures of foot structure and function. Copyright © 2012 Elsevier B.V. All rights reserved.

  4. Foot morphometric phenomena.

    PubMed

    Agić, Ante

    2007-06-01

    Knowledge of the foot morphometry is important for proper foot structure and function. Foot structure as a vital part of human body is important for many reasons. The foot anthropometric and morphology phenomena are analyzed together with hidden biomechanical descriptors in order to fully characterize foot functionality. For Croatian student population the scatter data of the individual foot variables were interpolated by multivariate statistics. Foot morphometric descriptors are influenced by many factors, such as life style, climate, and things of great importance in human society. Dominant descriptors related to fit and comfort are determined by the use 3D foot shape and advanced foot biomechanics. Some practical recommendations and conclusions for medical, sportswear and footwear practice are highlighted.

  5. Foot shape modeling.

    PubMed

    Luximon, Ameersing; Goonetilleke, Ravindra S

    2004-01-01

    This study is an attempt to show how a "standard" foot can be parameterized using foot length, foot width, foot height, and a measure of foot curvature so that foot shape can be predicted using these simple anthropometric measures. The prediction model was generated using 40 Hong Kong Chinese men, and the model was validated using a different group of 25 Hong Kong Chinese men. The results show that each individual foot shape may be predicted to a mean accuracy of 2.1 mm for the left foot and 2.4 mm for the right foot. Application of this research includes the potential design and development of custom footwear without the necessity of expensive 3-D scanning of feet.

  6. Insulated Foamy Viral Vectors

    PubMed Central

    Browning, Diana L.; Collins, Casey P.; Hocum, Jonah D.; Leap, David J.; Rae, Dustin T.; Trobridge, Grant D.

    2016-01-01

    Retroviral vector-mediated gene therapy is promising, but genotoxicity has limited its use in the clinic. Genotoxicity is highly dependent on the retroviral vector used, and foamy viral (FV) vectors appear relatively safe. However, internal promoters may still potentially activate nearby genes. We developed insulated FV vectors, using four previously described insulators: a version of the well-studied chicken hypersensitivity site 4 insulator (650cHS4), two synthetic CCCTC-binding factor (CTCF)-based insulators, and an insulator based on the CCAAT box-binding transcription factor/nuclear factor I (7xCTF/NF1). We directly compared these insulators for enhancer-blocking activity, effect on FV vector titer, and fidelity of transfer to both proviral long terminal repeats. The synthetic CTCF-based insulators had the strongest insulating activity, but reduced titers significantly. The 7xCTF/NF1 insulator did not reduce titers but had weak insulating activity. The 650cHS4-insulated FV vector was identified as the overall most promising vector. Uninsulated and 650cHS4-insulated FV vectors were both significantly less genotoxic than gammaretroviral vectors. Integration sites were evaluated in cord blood CD34+ cells and the 650cHS4-insulated FV vector had fewer hotspots compared with an uninsulated FV vector. These data suggest that insulated FV vectors are promising for hematopoietic stem cell gene therapy. PMID:26715244

  7. “They just scraped off the calluses”: a mixed methods exploration of foot care access and provision for people with rheumatoid arthritis in south-western Sydney, Australia

    PubMed Central

    2013-01-01

    Background There is little indication that foot health services in Australia are meeting modern day recommendations for Rheumatoid Arthritis (RA) patients. The overall objective of this study was to explore the current state of foot health services for patients with RA with an emphasis on identifying barriers to the receipt of appropriate foot care in South-West Sydney, New South Wales, Australia. Methods A mixed (quantitative and qualitative) approach was adopted. Indications for appropriate access to foot care were determined by comparing the foot health, disease and socio-demographic characteristics of patients with unmet foot care demands, foot care users and patients with no demands for foot care. Perceptions of provision of, and access to, foot care were explored by conducting telephone-based interviews using an interpretative phenomenology approach with thematic analysis. Results Twenty-nine participants took part in the cross-sectional quantitative research study design, and 12 participants took part in the interpretative phenomenological approach (qualitative study). Foot care access appeared to be driven predominantly by the presence of rearfoot deformity, which was significantly worse amongst participants in the foot care user group (p = 0.02). Five main themes emerged from the qualitative data: 1) impact of disease-related foot symptoms, 2) footwear difficulties, 3) medical/rheumatology encounters, 4) foot and podiatry care access and experiences, and 5) financial hardship. Conclusions Foot care provision does not appear to be driven by appropriate foot health characteristics such as foot pain or foot-related disability. There may be significant shortfalls in footwear and foot care access and provision in Greater Western Sydney. Several barriers to adequate foot care access and provision were identified and further efforts are required to improve access to and the quality of foot care for people who have RA. Integration of podiatry services within rheumatology centres could resolve unmet needs of people with RA by permitting rapid access to expert-led multidisciplinary foot care for people with RA. PMID:23938103

  8. "They just scraped off the calluses": a mixed methods exploration of foot care access and provision for people with rheumatoid arthritis in south-western Sydney, Australia.

    PubMed

    Hendry, Gordon J; Gibson, Kathryn A; Pile, Kevin; Taylor, Luke; Du Toit, Verona; Burns, Joshua; Rome, Keith

    2013-08-13

    There is little indication that foot health services in Australia are meeting modern day recommendations for Rheumatoid Arthritis (RA) patients. The overall objective of this study was to explore the current state of foot health services for patients with RA with an emphasis on identifying barriers to the receipt of appropriate foot care in South-West Sydney, New South Wales, Australia. A mixed (quantitative and qualitative) approach was adopted. Indications for appropriate access to foot care were determined by comparing the foot health, disease and socio-demographic characteristics of patients with unmet foot care demands, foot care users and patients with no demands for foot care. Perceptions of provision of, and access to, foot care were explored by conducting telephone-based interviews using an interpretative phenomenology approach with thematic analysis. Twenty-nine participants took part in the cross-sectional quantitative research study design, and 12 participants took part in the interpretative phenomenological approach (qualitative study). Foot care access appeared to be driven predominantly by the presence of rearfoot deformity, which was significantly worse amongst participants in the foot care user group (p = 0.02). Five main themes emerged from the qualitative data: 1) impact of disease-related foot symptoms, 2) footwear difficulties, 3) medical/rheumatology encounters, 4) foot and podiatry care access and experiences, and 5) financial hardship. Foot care provision does not appear to be driven by appropriate foot health characteristics such as foot pain or foot-related disability. There may be significant shortfalls in footwear and foot care access and provision in Greater Western Sydney. Several barriers to adequate foot care access and provision were identified and further efforts are required to improve access to and the quality of foot care for people who have RA. Integration of podiatry services within rheumatology centres could resolve unmet needs of people with RA by permitting rapid access to expert-led multidisciplinary foot care for people with RA.

  9. The experience of foot problems and decisions to access foot care in patients with rheumatoid arthritis: a qualitative study.

    PubMed

    Wilson, Oonagh; Kirwan, John; Dures, Emma; Quest, Enid; Hewlett, Sarah

    2017-01-01

    Although foot problems are common in rheumatoid arthritis (RA), the consequences of foot problems from the patient perspective have not been fully explored. The aims of this study were to explore the experience of foot problems and decisions to access foot care services or not in patients with RA. Semi structured, one-to-one interviews with patients recruited from 2 UK rheumatology units, purposively sampled for self-reported foot problems and a range of personal/disease characteristics. Inductive thematic analysis was used, with rigour provided by multiple independent analysers. Emerging themes were discussed and agreed by all authors. Twelve patients participated: 7 female; mean age 56 years (29-72); mean disease duration 12 years (2-27), 5 had accessed foot care services. The 'Impact' of foot problems was substantial and formed the underpinning theme, comprising three organising themes: 'Foot symptoms'; 'Consequences'; and 'Cost'. Foot symptoms such as pain and numbness required self-management, and affected daily life (walking, working) leading to social and emotional costs. The global theme, 'Decision to access foot care or not', also comprised three organising themes: 'Access perceived unnecessary' (no problem, can cope); 'Access hindered by patients' perception'; and 'Access supported by patient and clinician'. Decisions to access foot care or not were complex and influenced by patient beliefs regarding possible treatments and how to access these, and hindered by patient perceptions that their feet were ignored by rheumatology clinicians. Positive experience of foot care encouraged continued utilisation but negative experiences contributed to patients' decisions to discontinue foot care services. Foot problems are important issues for patients and impact on many aspects of their physical, social and emotional lives. Patients who had accessed foot care services prioritised their foot problems as an important health care need. However, for others who would like foot care services, personal knowledge and values, and perceived barriers in clinical practice, appear to interact to inhibit foot care access. The extent which these interactions affect overall access to foot care in RA patients in general now needs to be quantified to help to inform and improve the effectiveness of the organisation and delivery of foot care.

  10. Demonstration of Microsphere Insulation in Cryogenic Vessels

    NASA Astrophysics Data System (ADS)

    Baumgartner, R. G.; Myers, E. A.; Fesmire, J. E.; Morris, D. L.; Sokalski, E. R.

    2006-04-01

    While microspheres have been recognized as a legitimate insulation material for decades, actual use in full-scale cryogenic storage tanks has not been demonstrated until now. The performance and life-cycle-cost advantages previously predicted have now been proven. Most bulk cryogenic storage tanks are insulated with either multilayer insulation (MLI) or perlite. Microsphere insulation, consisting of hollow glass bubbles, combines in a single material the desirable properties that other insulations only have individually. The material has high crush strength, low density, is noncombustible, and performs well in soft vacuum. These properties were proven during recent field testing of two 22,700-L (6,000-gallon) liquid nitrogen tanks, one insulated with microsphere insulation and the other with perlite. Normal evaporation rates (NER) for both tanks were monitored with precision test equipment and insulation levels within the tanks were observed through view ports as an indication of insulation compaction. Specific industrial applications were evaluated based on the test results and beneficial properties of microsphere insulation. Over-the-road trailers previously insulated with perlite will benefit not only from the reduced heat leak, but also the reduced mass of microsphere insulation. Economic assessments for microsphere-insulated cryogenic vessels including life-cycle cost are also presented.

  11. The subsurface record for the Anthropocene based on the global analysis of deep wells

    NASA Astrophysics Data System (ADS)

    Rose, K.

    2016-12-01

    While challenges persist in the characterization of Earth's subsurface, over two centuries of exploration resulting in more than six million deep wellbores, offer insights into these systems. Characteristics of the subsurface vary and can be analyzed on a variety of spatial scales using geospatial tools and methods. Characterization and prediction of subsurface properties, such as depth, thickness, porosity, permeability, pressure and temperature, are important for models and interpretations of the subsurface. Subsurface studies contribute to insights and understanding of natural system but also enable predictions and assessments of subsurface resources and support environmental and geohazard assessments. As the geo-data science landscape shifts, becoming more open, there are increasing opportunities to fill knowledge gaps, mine large, interrelated datasets, and develop innovative methods to improve our understanding of the subsurface and the impacts of its exploration. In this study, a global dataset of more than 6,000,000 deep subsurface wells has been assembled using ArcGIS and Access, which reflects to a first order, the cumulative representation of over two centuries of drilling. Wellbore data, in general represent the only portal for direct measurement and characterization of deep subsurface properties. As human engineering of the subsurface evolves from a focus on hydrocarbon resource development to include subsurface waste product disposal (e.g. CO2, industrial waste, etc) and production of other deep subsurface resources, such as heat and water resources, there is the increasing need to improve characterization techniques and understand local and global ramifications of anthropogenic interaction with the subsurface. Data and geospatial analyses are reviewed to constrain the extent to which human interactions, not just with Earth's surface systems, atmospheric and geologic, but subsurface systems will result in an enduring signature of human influences on the planet. Specifically, the extent and enduring signature of subsurface interactions with the planet, utilizing the four-dimensional, spatial and temporal, record for known deep wellbores is utilized.

  12. Thermal insulation of young calves exposed to cold.

    PubMed Central

    Rawson, R E; Dziuk, H E; Good, A L; Anderson, J F; Bates, D W; Ruth, G R

    1989-01-01

    Tissue, external and whole animal insulation values were determined for 12 newborn male Holstein calves continuously housed for two weeks in hutches within environmental chambers in which temperature was maintained at a constant 17 degrees C (three calves) or cycled on a daily basis either between -20 degrees and -8 degrees C (three calves) or between -30 degrees and -18 degrees C (six calves). Three of the six calves at the coldest temperature were outfitted with an insulated coat. The insulated coat provided calves a 52% increase in total insulation. Tissue insulation of cold-housed calves increased 37.2% over the first two weeks of life. It was concluded that the capacity for vasoconstriction improved with age. External insulation did not change significantly except during the first week in cold-housed calves without insulated coats. External insulation values were five to eight times those of tissue insulation values for all treatment groups. This indicated that insulation of structures external to the skin (hair, bedding, ground, etc.) provided most of the insulation for calves. PMID:2766147

  13. Gender differences in foot shape: a study of Chinese young adults.

    PubMed

    Hong, Youlian; Wang, Lin; Xu, Dong Qing; Li, Jing Xian

    2011-06-01

    One important extrinsic factor that causes foot deformity and pain in women is footwear. Women's sports shoes are designed as smaller versions of men's shoes. Based on this, the current study aims to identify foot shape in 1,236 Chinese young adult men and 1,085 Chinese young adult women. Three-dimensional foot shape data were collected through video filming. Nineteen foot shape variables were measured, including girth (4 variables), length (4 variables), width (3 variables), height (7 variables), and angle (1 variable). A comparison of foot measures within the range of the common foot length (FL) categories indicates that women showed significantly smaller values of foot measures in width, height, and girth than men. Three foot types were classified, and distributions of different foot shapes within the same FL were found between women and men. Foot width, medial ball length, ball angle, and instep height showed significant differences among foot types in the same FL for both genders. There were differences in the foot shape between Chinese young women and men, which should be considered in the design of Chinese young adults' sports shoes.

  14. Nurses' knowledge of foot care in the context of home care: a cross-sectional correlational survey study.

    PubMed

    Stolt, Minna; Suhonen, Riitta; Puukka, Pauli; Viitanen, Matti; Voutilainen, Päivi; Leino-Kilpi, Helena

    2015-10-01

    This study aimed to explore nurses' knowledge of foot care and related factors in home care nursing. Nurses caring for older people are increasingly confronted with clients who have multiple foot problems and need support with their foot health. The role of nurses in promoting foot health, caring for existing foot problems and supporting older people in foot self-care is especially important in the home care context. However, this entails up-to-date foot care knowledge and practices. A cross-sectional correlational survey study design. Nurses' knowledge of foot care was evaluated using the Nurses' Foot Care Knowledge Test developed for this study. The data were analysed with descriptive and inferential statistics. Nurses (registered nurses, public health nurses and licensed practical nurses) from public home care (n = 322, response rate 50%) participated the study. Nurses' knowledge in foot care varied. The knowledge scores were highest for skin and nail care and lowest for the identification and care of foot structural deformities. Longer working experience in the current work place and participation in continuing education explained higher Nurses' Foot Care Knowledge Test scores. Nurses need more knowledge, and hence continuing education, in the foot care of older people to effectively prevent, recognise and care for foot problems and promote independent living in the community. Nurses' have clinically relevant knowledge gaps. Therefore, foot care knowledge of nurses needs to be improved by continuing education in clinical settings. Adequate foot care knowledge among nurses is important to identify, prevent and care foot problems especially in older people. © 2015 John Wiley & Sons Ltd.

  15. Associations of Region-Specific Foot Pain and Foot Biomechanics: The Framingham Foot Study

    PubMed Central

    Hagedorn, Thomas J.; Dufour, Alyssa B.; Hannan, Marian T.

    2015-01-01

    Background. Specific regions of the foot are responsible for the gait tasks of weight acceptance, single-limb support, and forward propulsion. With region foot pain, gait abnormalities may arise and affect the plantar pressure and force pattern utilized. Therefore, this study’s purpose was to evaluate plantar pressure and force pattern differences between adults with and without region-specific foot pain. Methods. Plantar pressure and force data were collected on Framingham Foot Study members while walking barefoot at a self-selected pace. Foot pain was evaluated by self-report and grouped by foot region (toe, forefoot, midfoot, or rearfoot) or regions (two or three or more regions) of pain. Unadjusted and adjusted linear regression with generalized estimating equations was used to determine associations between feet with and without foot pain. Results. Individuals with distal foot (forefoot or toes) pain had similar maximum vertical forces under the pain region, while those with proximal foot (rearfoot or midfoot) pain had different maximum vertical forces compared to those without regional foot pain (referent). During walking, there were significant differences in plantar loading and propulsion ranging from 2% to 4% between those with and without regional foot pain. Significant differences in normalized maximum vertical force and plantar pressure ranged from 5.3% to 12.4% and 3.4% to 24.1%, respectively, between those with and without regional foot pain. Conclusions. Associations of regional foot pain with plantar pressure and force were different by regions of pain. Region-specific foot pain was not uniformly associated with an increase or decrease in loading and pressure patterns regions of pain. PMID:25995291

  16. Effectiveness of foot care education among people with type 2 diabetes in rural Puducherry, India.

    PubMed

    Saurabh, Suman; Sarkar, Sonali; Selvaraj, Kalaiselvi; Kar, Sitanshu Sekhar; Kumar, S Ganesh; Roy, Gautam

    2014-01-01

    The burden of diabetes and its foot complications is increasing in India. Prevention of these complications through foot care education should be explored. The objective of our study was to assess the risk factors of poor diabetic foot care and to find the effectiveness of health education in improving foot care practice among diabetes patients. A structured pre-tested questionnaire was administered to the outpatients of a rural health center with type 2 diabetes. Awareness regarding diabetes, care of diabetes and foot care practice ware assessed and scored. Individual and group health education focusing on foot care was performed. Foot care practice was reassessed after 2 weeks of education. Only 54% were aware that diabetes could lead to reduced foot sensation and foot ulcers. Nearly 53% and 41% of the patients had good diabetes awareness and good diabetes care respectively. Only 22% of the patients had their feet examined by a health worker or doctor. The patients with poor, satisfactory and good practice scores were 44.7%, 35.9% and 19.4% respectively. Low education status, old age and low awareness regarding diabetes were the risk factors for poor practice of foot care. Average score for practice of foot care improved from 5.90 ± 1.82 to 8.0 ± 1.30 after 2 weeks of health education. Practice related to toe space examination, foot inspection and foot wear inspection improved maximally. Foot care education for diabetics in a primary care setting improves their foot care practice and is likely to be effective in reducing the burden of diabetic foot ulcer.

  17. Beneficial effects of foot care nursing for people with diabetes mellitus: an uncontrolled before and after intervention study.

    PubMed

    Fujiwara, Yuko; Kishida, Ken; Terao, Mika; Takahara, Mitsuyoshi; Matsuhisa, Munehide; Funahashi, Tohru; Shimomura, Iichiro; Shimizu, Yasuko

    2011-09-01

    The aim of this study was to assess the effectiveness of a preventative foot care nursing programme for diabetic patients. Foot complications are common in diabetic patients and prevention of such complications requires foot care. However, there is little information on the effectiveness of foot care nursing on the incidence and recurrence of diabetic foot. We developed a diabetic foot care programme based on the International Working Group on the Diabetic Foot. We studied 88 patients who attended our foot care programme for 2 years, and collected data from April 2005 to March 2009. Patients were divided into four groups according to the risk classification, and received foot care. We evaluated the incidence of foot ulceration or recurrence and non-ulcerated foot condition. Characteristics of the patients were analysed using the paired t-test and McNemar's test, and changes in severity of tinea pedis and grade of callus were analysed using Wilcoxon's signed rank sum test. The programme reduced the severity score of tinea pedis (P < 0·001) and improved callus grade (P < 0·001). All these were evaluated by Wilcoxon's signed rank sum test. None of the patients of risk-group-3 (history of foot ulceration) showed recurrence of callus-related foot ulcers. Six high-risk patients developed foot ulceration during the programme because of minor injury, but the ulcers healed without development of gangrene. A nurse-based foot care programme is effective in preventing diabetic foot in diabetic patients. © 2011 The Authors. Journal of Advanced Nursing © 2011 Blackwell Publishing Ltd.

  18. Dirac-electron-mediated magnetic proximity effect in topological insulator/magnetic insulator heterostructures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, Mingda; Song, Qichen; Zhao, Weiwei

    The possible realization of dissipationless chiral edge current in a topological insulator/magnetic insulator heterostructure is based on the condition that the magnetic proximity exchange coupling at the interface is dominated by the Dirac surface states of the topological insulator. We report a polarized neutron reflectometry observation of Dirac-electron-mediated magnetic proximity effect in a bulk-insulating topological insulator (Bi 0.2Sb 0.8) 2Te 3/magnetic insulator EuS heterostructure. We are able to maximize the proximity-induced magnetism by applying an electrical back gate to tune the Fermi level of topological insulator to be close to the Dirac point. A phenomenological model based on diamagnetic screeningmore » is developed to explain the suppressed proximity-induced magnetism at high carrier density. Our work paves the way to utilize the magnetic proximity effect at the topological insulator/magnetic insulator heterointerface for low-power spintronic applications.« less

  19. Dirac-electron-mediated magnetic proximity effect in topological insulator/magnetic insulator heterostructures

    DOE PAGES

    Li, Mingda; Song, Qichen; Zhao, Weiwei; ...

    2017-11-01

    The possible realization of dissipationless chiral edge current in a topological insulator/magnetic insulator heterostructure is based on the condition that the magnetic proximity exchange coupling at the interface is dominated by the Dirac surface states of the topological insulator. We report a polarized neutron reflectometry observation of Dirac-electron-mediated magnetic proximity effect in a bulk-insulating topological insulator (Bi 0.2Sb 0.8) 2Te 3/magnetic insulator EuS heterostructure. We are able to maximize the proximity-induced magnetism by applying an electrical back gate to tune the Fermi level of topological insulator to be close to the Dirac point. A phenomenological model based on diamagnetic screeningmore » is developed to explain the suppressed proximity-induced magnetism at high carrier density. Our work paves the way to utilize the magnetic proximity effect at the topological insulator/magnetic insulator heterointerface for low-power spintronic applications.« less

  20. 76 FR 25320 - Indian Blanket Water LLC; Notice of Preliminary Permit Application Accepted for Filing and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-05-04

    ...: (1) A 120-foot-high, 3,200-foot-long earth embankment dam; (2) a 30- foot-high, 300-foot-long earth...-foot storage capacity; (4) a 60-foot-high, 5,600-foot-long earth embankment dam creating; (5) a lower... characters, without prior registration, using the eComment system at http://www.ferc.gov/docs-filing/ecomment...

  1. 77 FR 71590 - New England Hydropower Company, LLC; Notice of Preliminary Permit Application Accepted for Filing...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-12-03

    ...-wide, and 10-foot-deep head box and intake channel; (4) a new 6-foot-high, 14-foot-wide sluice gate...) an existing 375-foot-long, 20- foot-wide, and 4-foot-deep tailrace; (8) a new above ground 300-foot... instructions on the Commission's Web site http://www.ferc.gov/docs-filing/efiling.asp . Commenters can submit...

  2. 78 FR 28838 - New England Hydropower Company, LLC; Notice of Preliminary Permit Application Accepted for Filing...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-05-16

    ... about 416.7 feet above mean sea level; (3) an existing 31- foot-long, 12.9-foot-wide, and 10-foot-deep...-foot-long, 30-foot-wide, and 4-foot-deep tailrace; (8) a new above-ground 365-foot-long, 35-kilovolt... Commission's Web site http://www.ferc.gov/docs-filing/efiling.asp . Commenters can submit brief comments up...

  3. 76 FR 28766 - Black Canyon Hydro, LLC; Notice of Preliminary Permit Application Accepted for Filing and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-05-18

    .... The proposed project would consist of the following: (1) An approximately 35-foot-wide, 7-foot-tall inflatable dam; (2) a 90-foot- wide, 7-foot-tall diversion intake structure; (3) a 9-foot-wide, 7- foot-tall...

  4. 77 FR 20806 - Nationwide Categorical Waivers Under the American Recovery and Reinvestment Act of 2009 (Recovery...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-04-06

    ... the insulation for leak detection and location); pre-insulated steel fittings with the same... in the insulation for leak detection and location); pre-insulated steel fittings with the same... the insulation for leak detection and location); pre-insulated steel fittings with the same...

  5. Heat insulating device for low temperature liquefied gas storage tank

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Okamoto, T.; Nishimoto, T.; Sawada, K.

    1978-05-02

    Hitachi Shipbuilding and Engineering Co., Ltd.'s insulation method for spherical LNG containers solves various problems associated with insulating a sphere's three-dimensional curved surface; equalizing the thickness of the insulation, insulating the junctions between insulation blocks, and preventing seawater or LNG from penetrating the insulation barrier in the event of a rupture in the tank and ship's hull. The design incorporates a number of blocks or plates of rigid foam-insulating material bonded to the outer wall; seats for receiving pressing jigs for the bonding operation are secured to the outer wall in the joints between the insulating blocks. The joints aremore » filled with soft synthetic foam (embedding the seats), a moistureproof layer covers the insulating blocks and joints, and a waterproof material covers the moistureproof layer.« less

  6. [Effects of functional interactions between nonhomologous insulators Wari and Su(Hw)].

    PubMed

    Erokhin, M M; Georgiev, P G; Chetverina, D A

    2010-01-01

    Insulators are regulatory DNA elements restricting gene activation by enhancers. Interactions between insulators can lead to both insulation and activation of promoters by enhancers. In this work, we analyzed the effects of interaction of two Drosophila insulators, Wari and Su(Hw). The functional interaction between these insulators was found to enhance the activity of the Su(Hw) insulator only, but not of the Wari insulator. This suggests that the formation of a chromatin loop between interacting insulators is not a key factor for enhancement of insulation, which is in disagreement with the main idea of structural models. In addition, the effect of interaction between Wari and Su(Hw) depends on a distance between them and on the position in the system relative to other regulatory elements.

  7. 76 FR 4097 - Erie Boulevard Hydropower, L.P.; Notice of Application Tendered for Filing With the Commission...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-01-24

    ... Oswegatchie River and consists of: (1) A 941-foot-long dam with a 192-foot-long, 69-foot-high concrete gravity... consists of: (1) A 568-foot-long dam and a 120-foot-long earthen embankment with a concrete core wall, and a 229- foot-long, 70-foot-high concrete gravity spillway with a crest elevation of 1,080.0 feet msl...

  8. The role of foot self-care behavior on developing foot ulcers in diabetic patients with peripheral neuropathy: a prospective study.

    PubMed

    Chin, Yen-Fan; Liang, Jersey; Wang, Woan-Shyuan; Hsu, Brend Ray-Sea; Huang, Tzu-Ting

    2014-12-01

    Although foot self-care behavior is viewed as beneficial for the prevention of diabetic foot ulceration, the effect of foot self-care behavior on the development of diabetic foot ulcer has received little empirical investigation. To explore the relationship between foot self-care practice and the development of diabetic foot ulcers among diabetic neuropathy patients in northern Taiwan. A longitudinal study was conducted at one medical center and one teaching hospital in northern Taiwan. A total of 295 diabetic patients who lacked sensitivity to a monofilament were recruited. Five subjects did not provide follow-up data; thus, only the data of 290 subjects were analyzed. The mean age was 67.0 years, and 72.1% had six or fewer years of education. Data were collected by a modified version of the physical assessment portion of the Michigan Neuropathy Screening Instrument and the Diabetes Foot Self-Care Behavior Scale. Cox regression was used to analyze the predictive power of foot self-care behaviors. A total of 29.3% (n=85) of diabetic neuropathy patients developed a diabetic foot ulcer by the one-year follow-up. The total score on the Diabetes Foot Self-Care Behavior Scale was significantly associated with the risk of developing foot ulcers (HR=1.04, 95% CI=1.01-1.07, p=0.004). After controlling for the demographic variables and the number of diabetic foot ulcer hospitalizations, however, the effect was non-significant (HR=1.03, 95% CI=1.00-1.06, p=0.061). Among the foot self-care behaviors, lotion-applying behavior was the only variable that significantly predicted the occurrence of diabetic foot ulcer, even after controlling for demographic variables and diabetic foot ulcer predictors (neuropathy severity, number of diabetic foot ulcer hospitalizations, insulin treatment, and peripheral vascular disease; HR=1.19, 95% CI=1.04-1.36, p=0.012). Among patients with diabetic neuropathy, foot self-care practice may be insufficient to prevent the occurrence of diabetic foot ulcer. Instead, lotion-applying behavior predicted the occurrence of diabetic foot ulcers in diabetic patients with neuropathy. Further studies are needed to explore the mechanism of lotion-applying behavior as it relates to the occurrence of diabetic foot ulcer. Copyright © 2014 Elsevier Ltd. All rights reserved.

  9. Diabetes - taking care of your feet

    MedlinePlus

    Diabetes - foot care - self-care; Diabetic foot ulcer - foot care; Diabetic neuropathy - foot care ... else to check your feet. Call your health care provider right way about any foot problems you ...

  10. Effectiveness of foot care education among people with type 2 diabetes in rural Puducherry, India

    PubMed Central

    Saurabh, Suman; Sarkar, Sonali; Selvaraj, Kalaiselvi; Kar, Sitanshu Sekhar; Kumar, S. Ganesh; Roy, Gautam

    2014-01-01

    Background: The burden of diabetes and its foot complications is increasing in India. Prevention of these complications through foot care education should be explored. The objective of our study was to assess the risk factors of poor diabetic foot care and to find the effectiveness of health education in improving foot care practice among diabetes patients. Materials and Methods: A structured pre-tested questionnaire was administered to the outpatients of a rural health center with type 2 diabetes. Awareness regarding diabetes, care of diabetes and foot care practice ware assessed and scored. Individual and group health education focusing on foot care was performed. Foot care practice was reassessed after 2 weeks of education. Results: Only 54% were aware that diabetes could lead to reduced foot sensation and foot ulcers. Nearly 53% and 41% of the patients had good diabetes awareness and good diabetes care respectively. Only 22% of the patients had their feet examined by a health worker or doctor. The patients with poor, satisfactory and good practice scores were 44.7%, 35.9% and 19.4% respectively. Low education status, old age and low awareness regarding diabetes were the risk factors for poor practice of foot care. Average score for practice of foot care improved from 5.90 ± 1.82 to 8.0 ± 1.30 after 2 weeks of health education. Practice related to toe space examination, foot inspection and foot wear inspection improved maximally. Conclusion: Foot care education for diabetics in a primary care setting improves their foot care practice and is likely to be effective in reducing the burden of diabetic foot ulcer. PMID:24701439

  11. The Relationships between Foot Arch Volumes and Dynamic Plantar Pressure during Midstance of Walking in Preschool Children

    PubMed Central

    Chang, Hsun-Wen; Chieh, Hsiao-Feng; Lin, Chien-Ju; Su, Fong-Chin; Tsai, Ming-June

    2014-01-01

    Objectives The purpose of this study was to examine the correlation between the foot arch volume measured from static positions and the plantar pressure distribution during walking. Methods A total of 27 children, two to six years of age, were included in this study. Measurements of static foot posture were obtained, including navicular height and foot arch volume in sitting and standing positions. Plantar pressure, force and contact areas under ten different regions of the foot were obtained during walking. Results The foot arch index was correlated (r = 0.32) with the pressure difference under the midfoot during the foot flat phase. The navicular heights and foot arch volumes in sitting and standing positions were correlated with the mean forces and pressures under the first (r = −0.296∼−0.355) and second metatarsals (r = −0.335∼−0.504) and midfoot (r = −0.331∼−0.496) during the stance phase of walking. The contact areas under the foot were correlated with the foot arch parameters, except for the area under the midfoot. Conclusions The foot arch index measured in a static position could be a functional index to predict the dynamic foot functions when walking. The foot arch is a factor which will influence the pressure distribution under the foot. Children with a lower foot arch demonstrated higher mean pressure and force under the medial forefoot and midfoot, and lower contact areas under the foot, except for the midfoot region. Therefore, children with flatfoot may shift their body weight to a more medial foot position when walking, and could be at a higher risk of soft tissue injury in this area. PMID:24736650

  12. A foot-care program to facilitate self-care by the elderly: a non-randomized intervention study.

    PubMed

    Omote, Shizuko; Watanabe, Arisu; Hiramatsu, Tomoko; Saito, Emiko; Yokogawa, Masami; Okamoto, Rie; Sakakibara, Chiaki; Ichimori, Akie; Kyota, Kaoru; Tsukasaki, Keiko

    2017-11-09

    We aimed to evaluate a foot-care awareness program designed to improve foot morphology, physical functioning, and fall prevention among the community-dwelling elderly. Eleven independent community-dwelling elderly women (aged 61-83 years) were provided with foot-care advice and shown effective foot-care techniques to perform regularly for 6 months, and compared with a control group of 10 elderly women who did not receive any intervention. Measurements of foot form, functional capacity, subjective foot movement, and physical function were taken at baseline and 6-month follow-up. At follow-up, improvements were seen in the intervention group in foot morphology, subjective foot movement, foot pressure, and balance. In the intervention group, 90% of women had maintained or improved foot form and none of them had fallen during the post-intervention period, compared to the control group where 30% improved foot form (p = 0.0075) and four (40%) of them had fallen. Therefore, a foot-care program may have the potential to prevent falls and improve mobility among the elderly. Trial Registration UMIN-CTR No. UMIN000029632. Date of Registration: October 19, 2017.

  13. Is the foot elevation the optimal position for wound healing of a diabetic foot?

    PubMed

    Park, D J; Han, S K; Kim, W K

    2010-03-01

    In managing diabetic foot ulcers, foot elevation has generally been recommended to reduce oedema and prevent other sequential problems. However, foot elevation may decrease tissue oxygenation of the foot more than the dependent position since the dependent position is known to increase blood flow within the arterial system. In addition, diabetic foot ulcers, which have peripheral vascular insufficiency, generally have less oedema than other wounds. Therefore, we argue that foot elevation may not be helpful for healing of vascularly compromised diabetic foot ulcers since adequate tissue oxygenation is an essential factor in diabetic wound healing. The purpose of this study was to evaluate the influence of foot height on tissue oxygenation and to determine the optimal foot position to accelerate wound healing of diabetic foot ulcers. This study included 122 cases (73 males and 47 females; two males had bilateral disease) of diabetic foot ulcer patients aged 40-93 years. Trans-cutaneous partial oxygen tension (TcpO(2)) values of diabetic feet were measured before and after foot elevation (n=21). Elevation was achieved by placing a foot over four cushions. We also measured foot TcpO(2) values before and after lowering the feet (n=122). Feet were lowered to the patient's tibial height, approximately 30-35 cm, beside a bed handrail. Due to the large number of lowering measurements, we divided them into five sub-groups according to initial TcpO(2.) Tissue oxygenation values were compared. Foot-elevation-lowered TcpO(2) values before and after elevation were 32.5+/-22.2 and 23.8+/-23.1 mmHg (p<0.01), respectively. Foot-lowering-augmented TcpO(2) values before and after lowering were 44.6+/-23.8 and 58.0+/-25.9 mmHg (p<0.01), respectively. The lower the initial TcpO(2) level, the more the TcpO(2) level increased. The foot lowering, rather than elevation, significantly augments TcpO(2) and may stimulate healing of diabetic foot ulcers. (c) 2008 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  14. The foot core system: a new paradigm for understanding intrinsic foot muscle function.

    PubMed

    McKeon, Patrick O; Hertel, Jay; Bramble, Dennis; Davis, Irene

    2015-03-01

    The foot is a complex structure with many articulations and multiple degrees of freedom that play an important role in static posture and dynamic activities. The evolutionary development of the arch of the foot was coincident with the greater demands placed on the foot as humans began to run. The movement and stability of the arch is controlled by intrinsic and extrinsic muscles. However, the intrinsic muscles are largely ignored by clinicians and researchers. As such, these muscles are seldom addressed in rehabilitation programmes. Interventions for foot-related problems are more often directed at externally supporting the foot rather than training these muscles to function as they are designed. In this paper, we propose a novel paradigm for understanding the function of the foot. We begin with an overview of the evolution of the human foot with a focus on the development of the arch. This is followed by a description of the foot intrinsic muscles and their relationship to the extrinsic muscles. We draw the parallels between the small muscles of the trunk region that make up the lumbopelvic core and the intrinsic foot muscles, introducing the concept of the foot core. We then integrate the concept of the foot core into the assessment and treatment of the foot. Finally, we call for an increased awareness of the importance of the foot core stability to normal foot and lower extremity function. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  15. Obese older adults suffer foot pain and foot-related functional limitation.

    PubMed

    Mickle, Karen J; Steele, Julie R

    2015-10-01

    There is evidence to suggest being overweight or obese places adults at greater risk of developing foot complications such as osteoarthritis, tendonitis and plantar fasciitis. However, no research has comprehensively examined the effects of overweight or obesity on the feet of individuals older than 60 years of age. Therefore we investigated whether foot pain, foot structure, and/or foot function is affected by obesity in older adults. Three hundred and twelve Australian men and women, aged over 60 years, completed validated questionnaires to establish the presence of foot pain and health related quality of life. Foot structure (anthropometrics and soft tissue thickness) and foot function (ankle dorsiflexion strength and flexibility, toe flexor strength, plantar pressures and spatiotemporal gait parameters) were also measured. Obese participants (BMI >30) were compared to those who were overweight (BMI=25-30) and not overweight (BMI <25). Obese participants were found to have a significantly higher prevalence of foot pain and scored significantly lower on the SF-36. Obesity was also associated with foot-related functional limitation whereby ankle dorsiflexion strength, hallux and lesser toe strength, stride/step length and walking speed were significantly reduced in obese participants compared to their leaner counterparts. Therefore, disabling foot pain and altered foot structure and foot function are consequences of obesity for older adults, and impact upon their quality of life. Interventions designed to reduce excess fat mass may relieve loading of the foot structures and, in turn, improve foot pain and quality of life for older obese individuals. Copyright © 2015 Elsevier B.V. All rights reserved.

  16. [Anlysis of foot biomechanics characteristic in 303 patients with type 2 diabetes mellitus].

    PubMed

    Li, Wen-Xia; Cao, Ying; Zou, Meng-Chen; Huang, Ying; Hu, Ping; Luo, Xiang-Rong; Jiang, Ya; Xue, Yao-Ming; Gao, Fang

    2016-10-20

    To investigate foot biomechanics characteristic of patients with type 2 diabetes mellitus. This study was conducted among 303 patients with type 2 diabetes. The whole foot was divided into 10 regions, namely the first toe (T1); the second to fifth toes (T2-5); the first, second, third, fourth, and fifth metatarsals (M1, M2, M3, M4, and M5, respectively); midfoot (MF), and the heel medial (HM). Foot arch index, foot angle and maximum peak pressure (MPP) of the 10 regions were measured using a Footscan gait system. The maximum peak pressure of 10 regions decreased in the order of M3>M2>HM>M4>HL>M1>M5>T1>ML>T2-5 for the left foot, and in the order of M3>M2>HM>M4>HL>M1>M5>T1>ML>T2-5 for the right foot. The MPP in M1 region was higher in the right than in the left foot (P<0.05). The MPP in M3, M4, M5, and MF was higher in the left than in the right foot (P<0.05). The percentage of high-risk foot (defined by a total plantar pressure ≥70 N/cm 2 ) was 34% on the left and 17.7% on the right. An increased BMI was associated with a significant increase in high-risk foot, but not for the right foot in underweight patients. Foot flat phase was extended and forefoot push-off phase shortened in stance phase in the patients. Compared with the right foot, the left foot showed a significantly increased foot arch index and increased low and high arch rates with a decreased normal arch rate. Total plantar pressure was higher in of the left high arch foot than in normal arch foot. The foot angle was significantly larger on the right than on the left. The bilateral total plantar pressures were significantly greater in male patients (P<0.05) and increased with age but were not associated with the duration of DM, foot angle, or glycosylated hemoglobin level. Diabetic patients have obvious alterations in foot biomechanics with abnormalities of the plantar pressure, and the percentage of high-risk foot increases in overweight and obese patients, suggesting the need of body weight control in these patients when administering offloading treatment for prevention of diabetic foot ulcer.

  17. Diabetic foot disease: From the evaluation of the “foot at risk” to the novel diabetic ulcer treatment modalities

    PubMed Central

    Amin, Noha; Doupis, John

    2016-01-01

    The burden of diabetic foot disease (DFD) is expected to increase in the future. The incidence of DFD is still rising due to the high prevalence of DFD predisposing factors. DFD is multifactorial in nature; however most of the diabetic foot amputations are preceded by foot ulceration. Diabetic peripheral neuropathy (DPN) is a major risk factor for foot ulceration. DPN leads to loss of protective sensation resulting in continuous unconscious traumas. Patient education and detection of high risk foot are essential for the prevention of foot ulceration and amputation. Proper assessment of the diabetic foot ulceration and appropriate management ensure better prognosis. Management is based on revascularization procedures, wound debridement, treatment of infection and ulcer offloading. Management and type of dressing applied are tailored according to the type of wound and the foot condition. The scope of this review paper is to describe the diabetic foot syndrome starting from the evaluation of the foot at risk for ulceration, up to the new treatment modalities. PMID:27076876

  18. Ceramic fiber insulation impregnated with an infra-red retardant coating and method for production thereof

    NASA Technical Reports Server (NTRS)

    Zinn, Alfred A. (Inventor); Tarkanian, Ryan Jeffrey (Inventor)

    2007-01-01

    The invented insulation is a ceramic fiber insulation wherein the ceramic fibers are treated with a coating which contains transition metal oxides. The invented process for coating the insulation is a process of applying the transition metal oxide coating to the fibers of the insulation after the fibers have been formed into a tile or other porous body. The coating of transition metal oxide lowers the transmittance of radiation through the insulation thereby lowering the temperature of the backface of the insulation and better protecting the structure that underlies the insulation.

  19. Athlete's Foot

    MedlinePlus

    ... this page. Please enable Javascript in your browser. Athlete's Foot Athlete's foot is a skin infection caused by fungus. A ... the body; on the foot, it is called athlete’s foot, or tinea pedis. Fungus commonly attacks the feet ...

  20. What Is a Foot and Ankle Surgeon?

    MedlinePlus

    ... Foot & Ankle Surgeon? A A A | Print | Share What is a Foot & Ankle Surgeon? Foot and ankle ... of conditions that affect people of every age. What education has a foot and ankle surgeon received? ...

  1. Foot posture, foot function and low back pain: the Framingham Foot Study

    PubMed Central

    Menz, Hylton B.; Dufour, Alyssa B.; Riskowski, Jody L.; Hillstrom, Howard J.

    2013-01-01

    Objective. Abnormal foot posture and function have been proposed as possible risk factors for low back pain, but this has not been examined in detail. The objective of this study was to explore the associations of foot posture and foot function with low back pain in 1930 members of the Framingham Study (2002–05). Methods. Low back pain, aching or stiffness on most days was documented on a body chart. Foot posture was categorized as normal, planus or cavus using static weight-bearing measurements of the arch index. Foot function was categorized as normal, pronated or supinated using the centre of pressure excursion index derived from dynamic foot pressure measurements. Sex-specific multivariate logistic regression models were used to examine the associations of foot posture, foot function and asymmetry with low back pain, adjusting for confounding variables. Results. Foot posture showed no association with low back pain. However, pronated foot function was associated with low back pain in women [odds ratio (OR) = 1.51, 95% CI 1.1, 2.07, P = 0.011] and this remained significant after adjusting for age, weight, smoking and depressive symptoms (OR = 1.48, 95% CI 1.07, 2.05, P = 0.018). Conclusion. These findings suggest that pronated foot function may contribute to low back symptoms in women. Interventions that modify foot function, such as orthoses, may therefore have a role in the prevention and treatment of low back pain. PMID:24049103

  2. Evaluation of European District Heating Systems for Application to Army Installations in the United States

    DTIC Science & Technology

    2006-07-01

    pipes in hooded channels, and the steel insulated pipes are insulated with mineral wool . In the thermo- concrete laying system the insulation...depends on the type foam insulation used. • Class “A” steel carrier pipe with a mineral wool , foam glass, fiber glass, or calcium silicate insulation...with a mineral wool , foam glass, fiber glass, or calcium silicate insulation covered by a steel con- duit, which has a polyurethane foam insulation

  3. Thermal Performance of Composite Flexible Blanket Insulations for Hypersonic Aerospace Vehicles

    NASA Technical Reports Server (NTRS)

    Kourtides, Demetrius A.

    1993-01-01

    This paper describes the thermal performance of a Composite Flexible Blanket Insulation (C.F.B.I.) considered for potential use as a thermal protection system or thermal insulation for future hypersonic vehicles such as the National Aerospace Plane (N.A.S.P.). Thermophysical properties for these insulations were also measured including the thermal conductivity at various temperatures and pressures and the emissivity of the fabrics used in the flexible insulations. The thermal response of these materials subjected to aeroconvective heating from a plasma arc is also described. Materials tested included two surface variations of the insulations, and similar insulations coated with a Protective Ceramic Coating (P.C.C.). Surface and backface temperatures were measured in the flexible insulations and on Fibrous Refractory Composite Insulation (F.R.C.I.) used as a calibration model. The uncoated flexible insulations exhibited good thermal performance up to 35 W/sq cm. The use of a P.C.C. to protect these insulations at higher heating rates is described. The results from a computerized thermal analysis model describing thermal response of those materials subjected to the plasma arc conditions are included. Thermal and optical properties were determined including thermal conductivity for the rigid and flexible insulations and emissivity for the insulation fabrics. These properties were utilized to calculate the thermal performance of the rigid and flexible insulations at the maximum heating rate.

  4. Health education programmes to improve foot self-care practices and foot problems among older people with diabetes: a systematic review.

    PubMed

    Ahmad Sharoni, Siti Khuzaimah; Minhat, Halimatus Sakdiah; Mohd Zulkefli, Nor Afiah; Baharom, Anisah

    2016-09-01

    To assess the effectiveness of health education programmes to improve foot self-care practices and foot problems among older people with diabetes. The complications of diabetes among older people are a major health concern. Foot problems such as neuropathy, ulcer and ultimately amputation are a great burden on older people with diabetes. Diabetes foot education programmes can influence the behaviour of older people in practising foot self-care and controlling the foot problems. However, the educational approaches used by the educators are different. Therefore, it is important to assess the education programmes from various evidence-based practices. Six databases, EBSCOhost medical collections (MEDLINE, CINAHL, Psychology and Behavioral Sciences Collection), SAGE, Wiley Online Library, ScienceDirect, SpringerLink and Web of Science, were used to search for articles published from January 2000 to March 2015. The search was based on the inclusion criteria and keywords including 'foot', 'care' and 'diabetes'. Fourteen studies were assessed and reviewed in the final stage. Health education programmes varied according to their design, setting, approach, outcome measured and results. Foot assessment, verbal and written instructions and discussion were proved to improve the foot self-care and foot problems. Subsequent follow-ups and evaluations had a significant effect. An improvement was observed in foot self-care scores and foot problems (such as neuropathy, foot disability, lesion, ulcer, tinea pedis and callus grade) after implementation of the health education programme. The findings of this study support the claim that a health education programme increases the foot self-care scores and reduces the foot problems. However, there were certain methodological concerns in the reviewed articles, indicating the need for further evaluation. In future, researchers and practitioners must implement a vigorous education programme focusing on diabetes foot self-care among the older population. © 2016 John Wiley & Sons Ltd.

  5. Foot Conditions among Homeless Persons: A Systematic Review

    PubMed Central

    To, Matthew J.; Brothers, Thomas D.; Van Zoost, Colin

    2016-01-01

    Introduction Foot problems are common among homeless persons, but are often overlooked. The objectives of this systematic review are to summarize what is known about foot conditions and associated interventions among homeless persons. Methods A literature search was conducted on MEDLINE (1966–2016), EMBASE (1947–2016), and CINAHL (1982–2016) and complemented by manual searches of reference lists. Articles that described foot conditions in homeless persons or associated interventions were included. Data were independently extracted on: general study characteristics; participants; foot assessment methods; foot conditions and associated interventions; study findings; quality score assessed using the Downs and Black checklist. Results Of 333 articles screened, 17 articles met criteria and were included in the study. Prevalence of any foot problem ranged from 9% to 65% across study populations. Common foot-related concerns were corns and calluses, nail pathologies, and infections. Foot pathologies related to chronic diseases such as diabetes were identified. Compared to housed individuals across studies, homeless individuals were more likely to have foot problems including tinea pedis, foot pain, functional limitations with walking, and improperly-fitting shoes. Discussion Foot conditions were highly prevalent among homeless individuals with up to two thirds reporting a foot health concern, approximately one quarter of individuals visiting a health professional, and one fifth of individuals requiring further follow-up due to the severity of their condition. Homeless individuals often had inadequate foot hygiene practices and improperly-fitting shoes. These findings have service provision and public health implications, highlighting the need for evidence-based interventions to improve foot health in this population. An effective interventional approach could include optimization of foot hygiene and footwear, provision of comprehensive medical treatment, and addressing social factors that lead to increased risk of foot problems. Targeted efforts to screen for and treat foot problems could result in improved health and social outcomes for homeless individuals. PMID:27936071

  6. 16 CFR 460.2 - What is home insulation.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... INSULATION § 460.2 What is home insulation. Insulation is any material mainly used to slow down heat flow. It... 16 Commercial Practices 1 2012-01-01 2012-01-01 false What is home insulation. 460.2 Section 460.2..., semirigid, flexible, or loose-fill form. Home insulation is for use in old or new homes, condominiums...

  7. 16 CFR 460.2 - What is home insulation.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... INSULATION § 460.2 What is home insulation. Insulation is any material mainly used to slow down heat flow. It... 16 Commercial Practices 1 2013-01-01 2013-01-01 false What is home insulation. 460.2 Section 460.2..., semirigid, flexible, or loose-fill form. Home insulation is for use in old or new homes, condominiums...

  8. 16 CFR 460.2 - What is home insulation.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... INSULATION § 460.2 What is home insulation. Insulation is any material mainly used to slow down heat flow. It... 16 Commercial Practices 1 2010-01-01 2010-01-01 false What is home insulation. 460.2 Section 460.2..., semirigid, flexible, or loose-fill form. Home insulation is for use in old or new homes, condominiums...

  9. 16 CFR 460.2 - What is home insulation.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... INSULATION § 460.2 What is home insulation. Insulation is any material mainly used to slow down heat flow. It... 16 Commercial Practices 1 2014-01-01 2014-01-01 false What is home insulation. 460.2 Section 460.2..., semirigid, flexible, or loose-fill form. Home insulation is for use in old or new homes, condominiums...

  10. 16 CFR 460.2 - What is home insulation.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... INSULATION § 460.2 What is home insulation. Insulation is any material mainly used to slow down heat flow. It... 16 Commercial Practices 1 2011-01-01 2011-01-01 false What is home insulation. 460.2 Section 460.2..., semirigid, flexible, or loose-fill form. Home insulation is for use in old or new homes, condominiums...

  11. Energy Conservation in the Home.

    DTIC Science & Technology

    1985-01-01

    inch of properly applied mineral wool insulation would provide. See Figure 2.1 (2:11...fiber. Mineral wool insulation is available in several different types, including blankets, blown insulation, poured insulation, and batts. Blankets...sidewalls can be insulated by a contractor who will blow in one ot several loose fill materials (National Mineral Wool Insulation Assn. Inc.). Figure 2.2

  12. 16 CFR 460.18 - Insulation ads.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 16 Commercial Practices 1 2010-01-01 2010-01-01 false Insulation ads. 460.18 Section 460.18... INSULATION § 460.18 Insulation ads. (a) If your ad gives an R-value, you must give the type of insulation and... the R-value, the greater the insulating power. Ask your seller for the fact sheet on R-values.” (b) If...

  13. 16 CFR 460.18 - Insulation ads.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 16 Commercial Practices 1 2014-01-01 2014-01-01 false Insulation ads. 460.18 Section 460.18... INSULATION § 460.18 Insulation ads. (a) If your ad gives an R-value, you must give the type of insulation and... the R-value, the greater the insulating power. Ask your seller for the fact sheet on R-values.” (b) If...

  14. 16 CFR 460.18 - Insulation ads.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 16 Commercial Practices 1 2013-01-01 2013-01-01 false Insulation ads. 460.18 Section 460.18... INSULATION § 460.18 Insulation ads. (a) If your ad gives an R-value, you must give the type of insulation and... the R-value, the greater the insulating power. Ask your seller for the fact sheet on R-values.” (b) If...

  15. 16 CFR 460.18 - Insulation ads.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 16 Commercial Practices 1 2012-01-01 2012-01-01 false Insulation ads. 460.18 Section 460.18... INSULATION § 460.18 Insulation ads. (a) If your ad gives an R-value, you must give the type of insulation and... the R-value, the greater the insulating power. Ask your seller for the fact sheet on R-values.” (b) If...

  16. 16 CFR 460.18 - Insulation ads.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 16 Commercial Practices 1 2011-01-01 2011-01-01 false Insulation ads. 460.18 Section 460.18... INSULATION § 460.18 Insulation ads. (a) If your ad gives an R-value, you must give the type of insulation and... the R-value, the greater the insulating power. Ask your seller for the fact sheet on R-values.” (b) If...

  17. Basalt fiber and nanoclay compositions, articles incorporating the same, and methods of insulating a rocket motor with the same

    NASA Technical Reports Server (NTRS)

    Gajiwala, Himansu M. (Inventor)

    2010-01-01

    An insulation composition that comprises at least one nitrile butadiene rubber, basalt fibers, and nanoclay is disclosed. Further disclosed is an insulation composition that comprises polybenzimidazole fibers, basalt fibers, and nanoclay. The basalt fibers may be present in the insulation compositions in a range of from approximately 1% by weight to approximately 6% by weight of the total weight of the insulation composition. The nanoclay may be present in the insulation compositions in a range of from approximately 5% by weight to approximately 10% by weight of the total weight of the insulation composition. Rocket motors including the insulation compositions and methods of insulating a rocket motor are also disclosed.

  18. Rocket motors incorporating basalt fiber and nanoclay compositions and methods of insulating a rocket motor with the same

    NASA Technical Reports Server (NTRS)

    Gajiwala, Himansu M. (Inventor)

    2011-01-01

    An insulation composition that comprises at least one nitrile butadiene rubber, basalt fibers, and nanoclay is disclosed. Further disclosed is an insulation composition that comprises polybenzimidazole fibers, basalt fibers, and nanoclay. The basalt fibers may be present in the insulation compositions in a range of from approximately 1% by weight to approximately 6% by weight of the total weight of the insulation composition. The nanoclay may be present in the insulation compositions in a range of from approximately 5% by weight to approximately 10% by weight of the total weight of the insulation composition. Rocket motors including the insulation compositions and methods of insulating a rocket motor are also disclosed.

  19. Insulated laser tube structure and method of making same

    DOEpatents

    Dittbenner, Gerald R.

    1999-01-01

    An insulated high temperature ceramic laser tube having substantially uniform insulation along the length of the tube is disclosed having particulate ceramic insulation positioned between the outer wall of the ceramic laser tube and the inner surface of tubular ceramic fiber insulation which surrounds the ceramic laser tube. The particulate ceramic insulation is preferably a ceramic capable of sintering to the outer surface of the ceramic laser tube and to the inner surface of the tubular ceramic fiber insulation. The addition of the particulate ceramic insulation to fill all the voids between the ceramic laser tube and the fibrous ceramic insulation permits the laser tube to be operated at a substantially uniform temperature throughout the length of the laser tube.

  20. Nurses' foot care activities in home health care.

    PubMed

    Stolt, Minna; Suhonen, Riitta; Puukka, Pauli; Viitanen, Matti; Voutilainen, Päivi; Leino-Kilpi, Helena

    2013-01-01

    This study described the basic foot care activities performed by nurses and factors associated with these in the home care of older people. Data were collected from nurses (n=322) working in nine public home care agencies in Finland using the Nurses' Foot Care Activities Questionnaire (NFAQ). Data were analyzed statistically using descriptive statistics and multivariate liner models. Although some of the basic foot care activities of nurses reported using were outdated, the majority of foot care activities were consistent with recommendations in foot care literature. Longer working experience, referring patients with foot problems to a podiatrist and physiotherapist, and patient education in wart and nail care were associated with a high score for adequate foot care activities. Continuing education should focus on updating basic foot care activities and increasing the use of evidence-based foot care methods. Also, geriatric nursing research should focus in intervention research to improve the use of evidence-based basic foot care activities. Copyright © 2013 Mosby, Inc. All rights reserved.

  1. Comparison of Foot Bathing and Foot Massage in Chemotherapy-Induced Peripheral Neuropathy.

    PubMed

    Park, Ranhee; Park, Chaisoon

    2015-01-01

    In a clinical setting, patients have been observed to complain of discomfort and to discontinue treatment because of chemotherapy-induced peripheral neuropathy (CIPN), but few data exist regarding the quality of life in these patients in Korea. The purpose of this quasi-experimental study was to analyze the effects of foot bathing and massage in patients with CIPN. Subjects included 48 patients with CIPN, who were hospitalized in C University Hospital. The subjects were alternately assigned to 1 of 2 groups according to their registration order. The interventions consisted of 8 treatments of foot bathing or massage over a period of 2 weeks, at 30 minutes per session, every other day. The foot skin temperature increased significantly in the foot bathing group, whereas it decreased significantly in the massage group. Quality of life was significantly increased in the foot bathing group, whereas it was significantly decreased in the massage group. Although foot bathing and foot massage are both supportive care techniques for CIPN patients, foot bathing was more effective than foot massage on skin temperature, grade of neurotoxicity, and quality of life. Additional well-designed studies are recommended, so that the effectiveness of foot bathing and foot massage is confirmed. Foot bathing is more useful as supportive care with respect to nonpharmacologic interventions for alleviating CIPN and promoting the quality of life in cancer patients.

  2. Technology Solutions for New and Existing Homes Case Study: Optimized Slab-on-Grade Foundation Insulation Retrofits

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    T. Schirber; Goldberg, L.; Mosiman, G.

    A more accurate assessment of SOG foundation insulation energy savings than traditionally possible is now feasible. This has been enabled by advances in whole building energy simulation with 3-dimensional foundation modelling integration at each time step together with an experimental measurement of the site energy savings of SOG foundation insulation. Ten SOG insulation strategies were evaluated on a test building to identify an optimum retrofit insulation strategy in a zone 6 climate (Minneapolis, MN). The optimum insulation strategy in terms of energy savings and cost effectiveness consisted of two components: (a) R-20 XPS insulation above grade, and, (b) R-20 insulationmore » at grade (comprising an outer layer of R-10 insulation and an interior layer of R-12 poured polyurethane insulation) tapering to R-10 XPS insulation at half the below-grade wall height (the lower half of the stem wall was uninsulated).« less

  3. High-Performance Slab-on-Grade Foundation Insulation Retrofits

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Goldberg, Louise F.; Mosiman, Garrett E.

    A more accurate assessment of slab-on-grade foundation insulation energy savings than traditionally possible is now feasible. This has been enabled by advances in whole building energy simulation with 3-dimensional foundation modelling integration at each time step together with an experimental measurement of the site energy savings of SOG foundation insulation. Ten SOG insulation strategies were evaluated on a test building to identify an optimum retrofit insulation strategy in a zone 6 climate (Minneapolis, MN). The optimum insulation strategy in terms of energy savings and cost effectiveness consisted of two components: (a) R-20 XPS insulation above grade, and, (b) R-20 insulationmore » at grade (comprising an outer layer of R-10 insulation and an interior layer of R-12 poured polyurethane insulation) tapering to R-10 XPS insulation at half the below-grade wall height (the lower half of the stem wall was uninsulated).« less

  4. Insulators form gene loops by interacting with promoters in Drosophila.

    PubMed

    Erokhin, Maksim; Davydova, Anna; Kyrchanova, Olga; Parshikov, Alexander; Georgiev, Pavel; Chetverina, Darya

    2011-09-01

    Chromatin insulators are regulatory elements involved in the modulation of enhancer-promoter communication. The 1A2 and Wari insulators are located immediately downstream of the Drosophila yellow and white genes, respectively. Using an assay based on the yeast GAL4 activator, we have found that both insulators are able to interact with their target promoters in transgenic lines, forming gene loops. The existence of an insulator-promoter loop is confirmed by the fact that insulator proteins could be detected on the promoter only in the presence of an insulator in the transgene. The upstream promoter regions, which are required for long-distance stimulation by enhancers, are not essential for promoter-insulator interactions. Both insulators support basal activity of the yellow and white promoters in eyes. Thus, the ability of insulators to interact with promoters might play an important role in the regulation of basal gene transcription.

  5. Foot posture is associated with kinematics of the foot during gait: A comparison of normal, planus and cavus feet.

    PubMed

    Buldt, Andrew K; Levinger, Pazit; Murley, George S; Menz, Hylton B; Nester, Christopher J; Landorf, Karl B

    2015-06-01

    Variations in foot posture are associated with the development of some lower limb injuries. However, the mechanisms underlying this relationship are unclear. The objective of this study was to compare foot kinematics between normal, pes cavus and pes planus foot posture groups using a multi-segment foot model. Ninety-seven healthy adults, aged 18-47 were classified as either normal (n=37), pes cavus (n=30) or pes planus (n=30) based on normative data for the Foot Posture Index, Arch Index and normalised navicular height. A five segment foot model was used to measure tri-planar motion of the rearfoot, midfoot, medial forefoot, lateral forefoot and hallux during barefoot walking at a self-selected speed. Angle at heel contact, peak angle, time to peak angle and range of motion was measured for each segment. One way ANOVAs with post-hoc analyses of mean differences were used to compare foot posture groups. The pes cavus group demonstrated a distinctive pattern of motion compared to the normal and pes planus foot posture groups. Effect sizes of significant mean differences were large and comparable to similar studies. Three key differences in overall foot function were observed between the groups: (i) altered frontal and transverse plane angles of the rearfoot in the pes cavus foot; (ii) Less midfoot motion in the pes cavus foot during initial contact and midstance; and (iii) reduced midfoot frontal plane ROM in the pes planus foot during pre-swing. These findings indicate that foot posture does influence motion of the foot. Copyright © 2015 Elsevier B.V. All rights reserved.

  6. Gait kinematics of subjects with ankle instability using a multisegmented foot model.

    PubMed

    De Ridder, Roel; Willems, Tine; Vanrenterghem, Jos; Robinson, Mark; Pataky, Todd; Roosen, Philip

    2013-11-01

    Many patients who sustain an acute lateral ankle sprain develop chronic ankle instability (CAI). Altered ankle kinematics have been reported to play a role in the underlying mechanisms of CAI. In previous studies, however, the foot was modeled as one rigid segment, ignoring the complexity of the ankle and foot anatomy and kinematics. The purpose of this study was to evaluate stance phase kinematics of subjects with CAI, copers, and controls during walking and running using both a rigid and a multisegmented foot model. Foot and ankle kinematics of 77 subjects (29 subjects with self-reported CAI, 24 copers, and 24 controls) were measured during barefoot walking and running using a rigid foot model and a six-segment Ghent Foot Model. Data were collected on a 20-m-long instrumented runway embedded with a force plate and a six-camera optoelectronic system. Groups were compared using statistical parametric mapping. Both the CAI and the coper group showed similar differences during midstance and late stance compared with the control group (P < 0.05). The rigid foot segment showed a more everted position during walking compared with the control group. Based on the Ghent Foot Model, the rear foot also showed a more everted position during running. The medial forefoot showed a more inverted position for both running and walking compared with the control group. Our study revealed significant midstance and late stance differences in rigid foot, rear foot, and medial forefoot kinematics The multisegmented foot model demonstrated intricate behavior of the foot that is not detectable with rigid foot modeling. Further research using these models is necessary to expand knowledge of foot kinematics in subjects with CAI.

  7. Diagnostic considerations of lateral column foot pain in athletes.

    PubMed

    Traister, Eric; Simons, Stephen

    2014-01-01

    Foot maladies are often classified descriptively by general foot locations, i.e., forefoot, midfoot, and rearfoot. However, common vernacular verbiage, implicating a common biomechanical purpose, also applies pathology to the medial or lateral foot column. Although imprecisely defined, lateral column injuries to the foot encompass conditions that affect any of the lateral side of the foot from the calcaneus to the toes. The lateral column of the foot includes the calcaneus, the cuboid, the fourth and fifth metatarsals as well as the calcaneocuboid, cuboido-metatarsal, and intermetatarsal joints. It may be helpful to think in a "lateral column" fashion when evaluating and treating certain lateral foot injuries, load patterns, and biomechanical or anatomical faults. Misdiagnosed injuries in this area of the foot can be a source of great morbidity to the athlete. It is important for the clinician to be aware of common conditions presenting as pain to the lateral side of the foot.

  8. Preparation and properties of the multi-layer aerogel thermal insulation composites

    NASA Astrophysics Data System (ADS)

    Wang, Miao; Feng, Junzong; Jiang, Yonggang; Zhang, Zhongming; Feng, Jian

    2018-03-01

    Multi-layer insulation materials possess low radiation thermal conductivity, and excellent thermal insulation property in a vacuum environment. However, the spacers of the traditional multi-layer insulation materials are mostly loose fibers, which lead to more sensitive to the vacuum environmental of serviced. With the vacuum degree declining, gas phases thermal convection increase obviously, and the reflective screen will be severe oxidation, all of these make the thermal insulation property of traditional multi-layer insulation deteriorate, thus limits its application scope. In this paper, traditional multi-layer insulation material is combined with aerogel and obtain a new multi-layer aerogel thermal insulation composite, and the effects of the number, thickness and type of the reflective screens on the thermal insulation properties of the multi-layer composites are also studied. The result is that the thermal insulation property of the new type multi-layer aerogel composites is better than the pure aerogel composites and the traditional multi-layer insulation composites. When the 0.01 mm stainless steel foil as the reflective screen, and the aluminum silicate fiber and silica aerogel as the spacer layer, the layer density of composite with the best thermal insulation property is one layer per millimeter at 1000 °C.

  9. A first principles investigation of electron transfer between Fe(II) and U(VI) on insulating Al- vs. semiconducting Fe-oxide surfaces via the proximity effect

    NASA Astrophysics Data System (ADS)

    Taylor, S. D.; Marcano, M. C.; Becker, U.

    2017-01-01

    This study investigates how the intrinsic chemical and electronic properties of mineral surfaces and their associated electron transfer (ET) pathways influence the reduction of U(VI) by surface-associated Fe(II). Density functional theory (DFT), including the Hubbard U correction to the exchange-correlation functional, was used to investigate sorption/redox reactions and ET mechanisms between Fe(II) and U(VI) coadsorbed on isostructural, periodic (0 0 1) surfaces of the insulator corundum (α-Al2O3) vs. the semiconductor hematite (α-Fe2O3). Furthermore, the coadsorbed Fe(II) and U(VI) ions are spatially separated from one another on the surfaces (⩾5.9 Å) to observe whether electronic-coupling through the semiconducting hematite surface facilitates ET between the adsorbates, a phenomenon known as the proximity effect. The calculations show that the different chemical and electronic properties between the isostructural corundum and hematite (0 0 1) surfaces lead to considerably different ET mechanisms between Fe(II) and U(VI). ET on the insulating corundum (0 0 1) surface is limited by the adsorbates' structural configuration. When Fe(II) and U(VI) are spatially separated and do not directly interact with one another (e.g. via an inner-sphere complex), U(VI) reduction by Fe(II) cannot occur as there is no physical pathway enabling ET between the adsorbates. In contrast to the insulating corundum (0 0 1) surface, the hematite (0 0 1) surface can potentially participate in ET reactions due to the high number of electron acceptor sites from the Fe d-states near the Fermi level at the hematite surface. The adsorption of Fe(II) also introduces d-states near the Fermi level as well as shifts unoccupied d-states of the Fe cations at the hematite surface to lower energies, making the surface more conductive. In turn, electronic coupling through the surface can link the spatially separated adsorbates to one another and provide distinct ET pathways for an electron from Fe(II) to travel through the hematite surface and reach U(VI). The progression and extent of ET occurring on the semiconducting hematite (0 0 1) surface via the proximity effect depends on the electronic properties of the surface. ET between the spatially separated U(VI) and Fe(II) occurs most readily when orbitals between the Fe and U adsorbates overlap with those of neighboring O and Fe ions at the hematite surface, as shown by calculations without the Hubbard U correction. Analyses of the spins densities confirm that the U and Fe adsorbates were reduced and oxidized, respectively, (acquiring 0.33 μB and 0.11-0.20 μB, respectively), while Fe cations at the hematite surface were reduced (losing ⩽0.6 μB). If electrons are highly localized, the amount of orbital mixing and electronic coupling through the hematite surface decreases and in turn leads to a lower degree of spin transfer, as predicted by calculations with the Hubbard U correction. Thus, the proximity effect is a potential mechanism on semiconducting surfaces facilitating surface-mediated redox reactions, although its significance varies depending on the electronic properties and subsequent charge-carrying ability of the surface. These results provide insight into ET pathways and mechanisms on insulating Al- and semiconducting Fe oxide surfaces influencing the reduction U(VI) by Fe(II) that may subsequently limit uranium's transport in the subsurface.

  10. The Development of 3d Sub-Surface Mapping Scheme and its Application to Martian Lobate Debris Aprons

    NASA Astrophysics Data System (ADS)

    Baik, H.; Kim, J.

    2017-07-01

    The Shallow Subsurface Radar (SHARAD), a sounding radar equipped on the Mars Reconnaissance Orbiter (MRO), has produced highly valuable information about the Martian subsurface. In particular, the complicated substructures of Mars such as polar deposit, pedestal crater and the other geomorphic features involving possible subsurface ice body has been successfully investigated by SHARAD. In this study, we established a 3D subsurface mapping strategy employing the multiple SHARAD profiles. A number of interpretation components of SHARAD signals were integrated into a subsurface mapping scheme using radargram information and topographic data, then applied over a few mid latitude Lobate Debris Aprons (LDAs). From the identified subsurface layers of LDA, and the GIS data base incorporating the other interpretation outcomes, we are expecting to trace the origin of LDAs. Also, the subsurface mapping scheme developed in this study will be further applied to other interesting Martian geological features such as inter crater structures, aeolian deposits and fluvial sediments. To achieve higher precision sub-surface mapping, the clutter simulation employing the high resolution topographic data and the upgraded clustering algorithms assuming multiple sub-surface layers will be also developed.

  11. Effects of Thai Foot Massage on Balance Performance in Diabetic Patients with Peripheral Neuropathy: A Randomized Parallel-Controlled Trial

    PubMed Central

    Chatchawan, Uraiwan; Eungpinichpong, Wichai; Plandee, Piyawan; Yamauchi, Junichiro

    2015-01-01

    Background Peripheral neuropathy is the most common complications of diabetic patients and leads to loss of plantar cutaneous sensation, movement perception, and body balance. Thai foot massage is an alternative therapy to improve balance. Therefore, the purpose of this study was to investigate the effects of Thai foot massage on balance performance in diabetic patients with peripheral neuropathy. Material/Methods Sixty patients with type-2 diabetes were recruited and randomly assigned into either the Thai foot massage or control groups. The Thai foot massage group received a modified Thai traditional foot massage for 30 min, 3 days per week for 2 weeks. We measured timed up and go (TUG), one leg stance: OLS), the range of motion (ROM) of the foot, and foot sensation (SWMT) before treatment, after the first single session, and after the 2-week treatment. Results After the single treatment session, only the Thai foot massage group showed a significant improvement in TUG. After the 2-week treatment, both Thai foot massage and control groups showed a significant improvement of TUG and OLS (P<0.05); however, when comparing between 2 groups, the Thai foot massage group showed better improvement in TUG than the control group (p<0.05). The Thai foot massage group also showed significant improvements in ROM and SWMT after the 2-week treatment. Conclusions The results of this study suggest that Thai foot massage is a viable alternative treatment for balance performance, ROM of the foot, and the foot sensation in diabetic patients with peripheral neuropathy. PMID:25892354

  12. Effects of thai foot massage on balance performance in diabetic patients with peripheral neuropathy: a randomized parallel-controlled trial.

    PubMed

    Chatchawan, Uraiwan; Eungpinichpong, Wichai; Plandee, Piyawan; Yamauchi, Junichiro

    2015-04-20

    BACKGROUND Peripheral neuropathy is the most common complications of diabetic patients and leads to loss of plantar cutaneous sensation, movement perception, and body balance. Thai foot massage is an alternative therapy to improve balance. Therefore, the purpose of this study was to investigate the effects of Thai foot massage on balance performance in diabetic patients with peripheral neuropathy. MATERIAL AND METHODS Sixty patients with type-2 diabetes were recruited and randomly assigned into either the Thai foot massage or control groups. The Thai foot massage group received a modified Thai traditional foot massage for 30 min, 3 days per week for 2 weeks. We measured timed up and go (TUG), one leg stance: OLS), the range of motion (ROM) of the foot, and foot sensation (SWMT) before treatment, after the first single session, and after the 2-week treatment. RESULTS After the single treatment session, only the Thai foot massage group showed a significant improvement in TUG. After the 2-week treatment, both Thai foot massage and control groups showed a significant improvement of TUG and OLS (P<0.05); however, when comparing between 2 groups, the Thai foot massage group showed better improvement in TUG than the control group (p<0.05). The Thai foot massage group also showed significant improvements in ROM and SWMT after the 2-week treatment. CONCLUSIONS The results of this study suggest that Thai foot massage is a viable alternative treatment for balance performance, ROM of the foot, and the foot sensation in diabetic patients with peripheral neuropathy.

  13. 77 FR 64496 - Freedom Falls, LLC; Notice of Application Ready for Environmental Analysis and Soliciting...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-10-22

    ... eel passage facility and working platform; (5) a new 60-foot-long, 30-inch-diameter steel penstock leading to; (6) an existing 20-foot-wide, by 30-foot- long generating room containing a new 38.3 kilowatt...-long, 12-foot-high concrete-capped stone masonry dam with a 25-foot-long, 10-foot-high spillway with...

  14. 75 FR 20589 - City of Oberlin, OH; Free Flow Power Missouri 1, LLC; Notice of Competing Preliminary Permit...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-20

    ... chambers. Oberlin's proposed project would consist of: (1) A new 155-foot- wide, 71-foot-tall water intake structure; (2) a new 155-foot-wide, 189-foot-long powerhouse containing three turbine generating units with...) A new 225- foot-wide, 50-foot-long water intake structure equipped with trashracks, sluice gates...

  15. Effect of foot shape on the three-dimensional position of foot bones.

    PubMed

    Ledoux, William R; Rohr, Eric S; Ching, Randal P; Sangeorzan, Bruce J

    2006-12-01

    To eliminate some of the ambiguity in describing foot shape, we developed three-dimensional (3D), objective measures of foot type based on computerized tomography (CT) scans. Feet were classified via clinical examination as pes cavus (high arch), neutrally aligned (normal arch), asymptomatic pes planus (flat arch with no pain), or symptomatic pes planus (flat arch with pain). We enrolled 10 subjects of each foot type; if both feet were of the same foot type, then each foot was scanned (n=65 total). Partial weightbearing (20% body weight) CT scans were performed. We generated embedded coordinate systems for each foot bone by assuming uniform density and calculating the inertial matrix. Cardan angles were used to describe five bone-to-bone relationships, resulting in 15 angular measurements. Significant differences were found among foot types for 12 of the angles. The angles were also used to develop a classification tree analysis, which determined the correct foot type for 64 of the 65 feet. Our measure provides insight into how foot bone architecture differs between foot types. The classification tree analysis demonstrated that objective measures can be used to discriminate between feet with high, normal, and low arches. Copyright (c) 2006 Orthopaedic Research Society.

  16. Sex determination from hand and foot dimensions in a North Indian population.

    PubMed

    Krishan, Kewal; Kanchan, Tanuj; Sharma, Abhilasha

    2011-03-01

    Hands and feet are often recovered from the site of natural as well as man-made disasters because of bomb blasts, train accidents, plane crashes, or mass homicides. This study is intended to establish standards for determination of sex from the dimensions of hands and feet in a North Indian population. The data for this study comprise 123 men and 123 women aged between 17 and 20 years from the "Rajput" population of Himachal Pradesh in North India. Four anthropometric measurements viz. hand length, hand breadth, foot length, and foot breadth have been taken on both sides of each subject following international anthropometric standards. The hand index (hand breadth/hand length × 100) and the foot index (foot breadth/foot length × 100) were calculated. Sectioning points and regression models are derived for the hand and foot dimensions and the derived indices. The hand and foot dimensions show a higher accuracy in sex determination by sectioning point analysis when compared to hand and foot index. Of the hand and the foot dimensions, hand breadth and foot breadth showed better accuracy in sex determination. Hand index and foot index remain poor sex discriminators in the study. © 2011 American Academy of Forensic Sciences.

  17. The generation of centripetal force when walking in a circle: insight from the distribution of ground reaction forces recorded by plantar insoles.

    PubMed

    Turcato, Anna Maria; Godi, Marco; Giordano, Andrea; Schieppati, Marco; Nardone, Antonio

    2015-01-09

    Turning involves complex reorientation of the body and is accompanied by asymmetric motion of the lower limbs. We investigated the distribution of the forces under the two feet, and its relation to the trajectory features and body medio-lateral displacement during curved walking. Twenty-six healthy young participants walked under three different randomized conditions: in a straight line (LIN), in a circular clockwise path and in a circular counter-clockwise path. Both feet were instrumented with Pedar-X insoles. An accelerometer was fixed to the trunk to measure the medio-lateral inclination of the body. We analyzed walking speed, stance duration as a percent of gait cycle (%GC), the vertical component of the ground reaction force (vGRF) of both feet during the entire stance, and trunk inclination. Gait speed was faster during LIN than curved walking, but not affected by the direction of the curved trajectory. Trunk inclination was negligible during LIN, while the trunk was inclined toward the center of the path during curved trajectories. Stance duration of LIN foot and foot inside the curved trajectory (Foot-In) was longer than for foot outside the trajectory (Foot-Out). vGRF at heel strike was larger in LIN than in curved walking. At mid-stance, vGRF for both Foot-In and Foot-Out was higher than for LIN foot. At toe off, vGRF for both Foot-In and Foot-Out was lower than for LIN foot; in addition, Foot-In had lower vGRF than Foot-Out. During curved walking, a greater loading of the lateral heel occurred for Foot-Out than Foot-In and LIN foot. On the contrary, a smaller lateral loading of the heel was found for Foot-In than LIN foot. At the metatarsal heads, an opposite behaviour was seen, since lateral loading decreased for Foot-Out and increased for Foot-In. The lower gait speed during curved walking is shaped by the control of trunk inclination and the production of asymmetric loading of heel and metatarsal heads, hence by the different contribution of the feet in producing the body inclination towards the centre of the trajectory.

  18. 40 CFR 763.163 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... asbestos-containing product which is made of paper intended for use as general insulation paper or muffler paper. Major applications of commercial papers are insulation against fire, heat transfer, and corrosion... include: thermal insulation for pipe coverings; block insulation; panel insulation in elevators...

  19. 40 CFR 763.163 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... asbestos-containing product which is made of paper intended for use as general insulation paper or muffler paper. Major applications of commercial papers are insulation against fire, heat transfer, and corrosion... include: thermal insulation for pipe coverings; block insulation; panel insulation in elevators...

  20. 40 CFR 763.163 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... asbestos-containing product which is made of paper intended for use as general insulation paper or muffler paper. Major applications of commercial papers are insulation against fire, heat transfer, and corrosion... include: thermal insulation for pipe coverings; block insulation; panel insulation in elevators...

  1. 40 CFR 763.163 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... asbestos-containing product which is made of paper intended for use as general insulation paper or muffler paper. Major applications of commercial papers are insulation against fire, heat transfer, and corrosion... include: thermal insulation for pipe coverings; block insulation; panel insulation in elevators...

  2. 40 CFR 763.163 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... asbestos-containing product which is made of paper intended for use as general insulation paper or muffler paper. Major applications of commercial papers are insulation against fire, heat transfer, and corrosion... include: thermal insulation for pipe coverings; block insulation; panel insulation in elevators...

  3. An Evaluation of Surgical Functional Reconstruction of the Foot Using Kinetic and Kinematic Systems: A Case Report.

    PubMed

    Jordán-Palomar, Elena Irene; Javierre, Etelvina; Rey-Vasalo, José; Alfaro-Santafé, Víctor; Gómez-Benito, María José

    Most pedobarographic studies of microsurgical foot reconstruction have been retrospective. In the present study, we report the results from a prospective pedobarographic study of a patient after microsurgical reconstruction of her foot with a latissimus dorsi flap and a cutaneous paddle, with a 42-month follow-up period. We describe the foot reconstruction plan and the pedobarographic measurements and analyzed its functional outcome. The goal of the present study was to demonstrate that pedobarography could have a role in the treatment of foot reconstruction from a quantitative perspective. The pedobarographic measurements were recorded after the initial coverage surgery and 2 subsequent foot remodeling procedures. A total of 4 pedobarographic measurements and 2 gait analyses were recorded and compared for both the noninvolved foot and the injured foot. Furthermore, the progress of the reconstructed foot was critically evaluated using this method. Both static and dynamic patterns were compared at subsequent follow-up visits after the foot reconstruction. The values and progression of the foot shape, peak foot pressure (kPa), average foot pressure (kPa), total contact surface (cm 2 ), loading time (%), and step time (ms) were recorded. Initially, the pressure distribution of the reconstructed foot showed higher peak values at nonanatomic locations, revealing a greater ulceration risk. Over time, we found an improvement in the shape and values of these factors in the involved foot. To homogenize the pressure distribution and correct the imbalance between the 2 feet, patient-specific insoles were designed and fabricated. In our patient, pedobarography provided an objective, repeatable, and recordable method for the evaluation of the reconstructed foot. Pedobarography can therefore provide valuable insights into the prevention of pressure ulcers and optimization of rehabilitation. Copyright © 2016 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  4. Foot preferences during resting in wildfowl and waders.

    PubMed

    Randler, Christoph

    2007-03-01

    Footedness in birds has been reported, e.g., in parrots and chickens, but the direction of footedness remained unclear. Is a bird left-footed because it uses its left foot for holding and handling food, or is it right-footed because it uses the right foot for stabilisation and balancing while perching? In 2004 and 2006 I examined footedness in wildfowl and waders while the birds were performing a single task: roosting on the ground on one foot. Avocet (Recurvirostra avosetta), northern shoveller (Anas clypeata), oystercatcher (Haematopus ostralegus), and Eurasian curlew (Numenius arquata) were right-footed. Another 21 species did not show any significant foot preferences. This study provides some evidence that asymmetries in preferential foot use in birds may be triggered by a preference during postural control.

  5. Chromatin insulator bodies are nuclear structures that form in response to osmotic stress and cell death

    PubMed Central

    Schoborg, Todd; Rickels, Ryan; Barrios, Josh

    2013-01-01

    Chromatin insulators assist in the formation of higher-order chromatin structures by mediating long-range contacts between distant genomic sites. It has been suggested that insulators accomplish this task by forming dense nuclear foci termed insulator bodies that result from the coalescence of multiple protein-bound insulators. However, these structures remain poorly understood, particularly the mechanisms triggering body formation and their role in nuclear function. In this paper, we show that insulator proteins undergo a dramatic and dynamic spatial reorganization into insulator bodies during osmostress and cell death in a high osmolarity glycerol–p38 mitogen-activated protein kinase–independent manner, leading to a large reduction in DNA-bound insulator proteins that rapidly repopulate chromatin as the bodies disassemble upon return to isotonicity. These bodies occupy distinct nuclear territories and contain a defined structural arrangement of insulator proteins. Our findings suggest insulator bodies are novel nuclear stress foci that can be used as a proxy to monitor the chromatin-bound state of insulator proteins and provide new insights into the effects of osmostress on nuclear and genome organization. PMID:23878275

  6. The role of foot morphology on foot function in diabetic subjects with or without neuropathy.

    PubMed

    Guiotto, Annamaria; Sawacha, Zimi; Guarneri, Gabriella; Cristoferi, Giuseppe; Avogaro, Angelo; Cobelli, Claudio

    2013-04-01

    The aim of this study was to investigate the role of foot morphology, related with respect to diabetes and peripheral neuropathy in altering foot kinematics and plantar pressure during gait. Healthy and diabetic subjects with or without neuropathy with different foot types were analyzed. Three dimensional multisegment foot kinematics and plantar pressures were assessed on 120 feet: 40 feet (24 cavus, 20 with valgus heel and 11 with hallux valgus) in the control group, 80 feet in the diabetic (25 cavus 13 with valgus heel and 13 with hallux valgus) and the neuropathic groups (28 cavus, 24 with valgus heel and 18 with hallux valgus). Subjects were classified according to their foot morphology allowing further comparisons among the subgroups with the same foot morphology. When comparing neuropathic subjects with cavus foot, valgus heel with controls with the same foot morphology, important differences were noticed: increased dorsiflexion and peak plantar pressure on the forefoot (P<0.05), decreased contact surface on the hindfoot (P<0.03). While results indicated the important role of foot morphology in altering both kinematics and plantar pressure in diabetic subjects, diabetes appeared to further contribute in altering foot biomechanics. Surprisingly, all the diabetic subjects with normal foot arch or with valgus hallux were no more likely to display significant differences in biomechanics parameters than controls. This data could be considered a valuable support for future research on diabetic foot function, and in planning preventive interventions. Copyright © 2012 Elsevier B.V. All rights reserved.

  7. Change in ocean subsurface environment to suppress tropical cyclone intensification under global warming.

    PubMed

    Huang, Ping; Lin, I-I; Chou, Chia; Huang, Rong-Hui

    2015-05-18

    Tropical cyclones (TCs) are hazardous natural disasters. Because TC intensification is significantly controlled by atmosphere and ocean environments, changes in these environments may cause changes in TC intensity. Changes in surface and subsurface ocean conditions can both influence a TC's intensification. Regarding global warming, minimal exploration of the subsurface ocean has been undertaken. Here we investigate future subsurface ocean environment changes projected by 22 state-of-the-art climate models and suggest a suppressive effect of subsurface oceans on the intensification of future TCs. Under global warming, the subsurface vertical temperature profile can be sharpened in important TC regions, which may contribute to a stronger ocean coupling (cooling) effect during the intensification of future TCs. Regarding a TC, future subsurface ocean environments may be more suppressive than the existing subsurface ocean environments. This suppressive effect is not spatially uniform and may be weak in certain local areas.

  8. Change in ocean subsurface environment to suppress tropical cyclone intensification under global warming

    PubMed Central

    Huang, Ping; Lin, I. -I; Chou, Chia; Huang, Rong-Hui

    2015-01-01

    Tropical cyclones (TCs) are hazardous natural disasters. Because TC intensification is significantly controlled by atmosphere and ocean environments, changes in these environments may cause changes in TC intensity. Changes in surface and subsurface ocean conditions can both influence a TC's intensification. Regarding global warming, minimal exploration of the subsurface ocean has been undertaken. Here we investigate future subsurface ocean environment changes projected by 22 state-of-the-art climate models and suggest a suppressive effect of subsurface oceans on the intensification of future TCs. Under global warming, the subsurface vertical temperature profile can be sharpened in important TC regions, which may contribute to a stronger ocean coupling (cooling) effect during the intensification of future TCs. Regarding a TC, future subsurface ocean environments may be more suppressive than the existing subsurface ocean environments. This suppressive effect is not spatially uniform and may be weak in certain local areas. PMID:25982028

  9. Multiple density layered insulator

    DOEpatents

    Alger, Terry W.

    1994-01-01

    A multiple density layered insulator for use with a laser is disclosed wh provides at least two different insulation materials for a laser discharge tube, where the two insulation materials have different thermoconductivities. The multiple layer insulation materials provide for improved thermoconductivity capability for improved laser operation.

  10. Deformity or dysfunction? Osteopathic manipulation of the idiopathic cavus foot: A clinical suggestion.

    PubMed Central

    Gidali, Adi; Harris, Valerie

    2010-01-01

    Observed gait abnormalities are often related to a variety of foot deformities such as the cavus foot, also known as pes cavus, cavovarus, uncompensated varus, and the high arched foot. When gait abnormalities related to cavus foot deformities produce symptoms or contribute to dysfunctional movement of the lower extremity, foot orthotics are commonly used to accommodate the deformity and optimize the function of the lower extremity. In more severe cases, surgical intervention is common. Hypomobility of the many joints of the foot and ankle may be mistaken as an idiopathic cavus foot deformity. As for any other limb segment suspected of musculoskeletal dysfunction, it is suggested that joint mobility testing and mobilization, if indicated, be attempted on the foot and ankle joints before assuming the presence of a bony cavus deformity. The purpose of this clinical suggestion is to describe the use of osteopathic manipulations of the foot and ankle in the context of an illustrative case of bilateral idiopathic cavus feet to demonstrate that apparent foot deformities may actually be joint hypomobility dysfunctions. PMID:21509155

  11. Method and apparatus for fabrication of high gradient insulators with parallel surface conductors spaced less than one millimeter apart

    DOEpatents

    Sanders, David M.; Decker, Derek E.

    1999-01-01

    Optical patterns and lithographic techniques are used as part of a process to embed parallel and evenly spaced conductors in the non-planar surfaces of an insulator to produce high gradient insulators. The approach extends the size that high gradient insulating structures can be fabricated as well as improves the performance of those insulators by reducing the scale of the alternating parallel lines of insulator and conductor along the surface. This fabrication approach also substantially decreases the cost required to produce high gradient insulators.

  12. Onset Time of Nerve Block: A Comparison of Two Injection Locations in Patients Having Lower Leg/ Foot Surgery

    ClinicalTrials.gov

    2014-03-20

    Strain of Muscle and/or Tendon of Lower Leg; Fracture of Lower Leg; Crushing Injury of Lower Leg; Fracture Malunion - Ankle and/or Foot; Disorder of Joint of Ankle and/or Foot; Complete Tear, Ankle and/or Foot Ligament; Pathological Fracture - Ankle and/or Foot; Loose Body in Joint of Ankle and/or Foot

  13. 78 FR 66910 - Notice of Competing Preliminary Permit Applications Accepted for Filing and Soliciting Comments...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-11-07

    ...-foot-tall water intake structure; (2) a 155-foot-wide, 189-foot-long concrete powerhouse containing two turbine-generators each rated at 25 megawatts (MW) for a total installed capacity of 50 MW; (3) a 160-foot... Island dam structure and consist of: (1) A 225-foot-wide, 50-foot-long water intake structure; (2) a 160...

  14. 78 FR 26359 - Community of Elfin Cove, DBA Elfin Cove Utility Commission; Notice of Preliminary Permit...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-05-06

    ...-kilowatt (kW) power recovery turbine; (4) a 25-foot-long, 8-foot- wide, 3-foot-deep cobble-lined tailrace... 150-foot-long, 8- foot-wide, 3-foot-deep cobble-lined tailrace discharging flows into Port Althorp... electronically via the Internet. See 18 CFR 385.2001(a)(1)(iii) and the instructions on the Commission's Web site...

  15. Development of High Performance Composite Foam Insulation with Vacuum Insulation Cores

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Biswas, Kaushik; Desjarlais, Andre Omer; SmithPhD, Douglas

    Development of a high performance thermal insulation (thermal resistance or R-value per inch of R-12 hr-ft2- F/Btu-in or greater), with twice the thermal resistance of state-of-the-art commercial insulation materials ( R6/inch for foam insulation), promises a transformational impact in the area of building insulation. In 2010, in the US, the building envelope-related primary energy consumption was 15.6 quads, of which 5.75 quads were due to opaque wall and roof sections; the total US consumption (building, industrial and transportation) was 98 quads. In other words, the wall and roof contribution was almost 6% of the entire US primary energy consumption. Buildingmore » energy modeling analyses have shown that adding insulation to increase the R-value of the external walls of residential buildings by R10-20 (hr-ft2- F/Btu) can yield savings of 38-50% in wall-generated heating and cooling loads. Adding R20 will require substantial thicknesses of current commercial insulation materials, often requiring significant (and sometimes cost-prohibitive) alterations to existing buildings. This article describes the development of a next-generation composite insulation with a target thermal resistance of R25 for a 2 inch thick board (R12/inch or higher). The composite insulation will contain vacuum insulation cores, which are nominally R35-40/inch, encapsulated in polyisocyanurate foam. A recently-developed variant of vacuum insulation, called modified atmosphere insulation (MAI), was used in this research. Some background information on the thermal performance and distinguishing features of MAI has been provided. Technical details of the composite insulation development and manufacturing as well as laboratory evaluation of prototype insulation boards are presented.« less

  16. Flat Foot in a Random Population and its Impact on Quality of Life and Functionality

    PubMed Central

    Gonzalez-Martin, Cristina; Alonso-Tajes, Francisco; Seoane-Pillado, Teresa; Pertega-Diaz, Sonia; Perez-Garcia, Sergio; Seijo-Bestilleiro, Rocio; Balboa-Barreiro, Vanesa

    2017-01-01

    Introduction Flat foot is a common deformity in adults. It is characterized by medial rotation and plantar flexion of the talus, eversion of the calcaneus, collapsed medial arch and abduction of the forefoot. Aim The aim of this study was to determine the prevalence of flat foot and its impact on quality of life, dependence, foot pain, disability and functional limitation among random population of 40-year-old and above. Materials and Methods A cross-sectional study in a random population sample from Cambre (A Coruña-Spain) (n=835) was performed (α =0.05; Precision=±3.4%). The diagnosis of flat foot was stablished by the study of the footprint obtained with a pedograph. Anthropometric variables were studied, Charlson’s Comorbidity Index, function and state of foot (Foot Function Index (FFI), Foot Health Status Questionnaire (FHSQ)), quality of life (SF-36), and dependence for activities of daily living (Barthel and Lawton index). A logistic and linear multiple regression analysis was performed. Results The prevalence of flat foot was 26.62%. Patients with flat foot were significantly older (65.73±11.04 vs 61.03±11.45-year-old), showed a higher comorbidity index (0.92±1.49 vs 0.50±0.98), had a greater BMI (31.45±5.55 vs 28.40±4.17) and greater foot size (25.16±1.66 vs 24.82±1.65). The presence of flat foot diminishes the quality of life, as measured by the FHSQ, and foot function, measured by the FFI. The presence of flat foot does not alter the physical and mental dimension of the SF-36 or the degree of dependence. Conclusion Flat foot was associated with age, Charlson’s Comorbidity Index, BMI and foot size. The SF-36, Barthel and Lawton questionnaires remained unaltered by the presence of flat foot. The FHSQ and FFI questionnaires did prove to be sensitive to the presence of flat foot in a significant manner. PMID:28571173

  17. Design of Chern insulating phases in honeycomb lattices

    NASA Astrophysics Data System (ADS)

    Pickett, Warren E.; Lee, Kwan-Woo; Pentcheva, Rossitza

    2018-06-01

    The search for robust examples of the magnetic version of topological insulators, referred to as quantum anomalous Hall insulators or simply Chern insulators, so far lacks success. Our groups have explored two distinct possibilities based on multiorbital 3d oxide honeycomb lattices. Each has a Chern insulating phase near the ground state, but materials parameters were not appropriate to produce a viable Chern insulator. Further exploration of one of these classes, by substituting open shell 3d with 4d and 5d counterparts, has led to realistic prediction of Chern insulating ground states. Here we recount the design process, discussing the many energy scales that are active in participating (or resisting) the desired Chern insulator phase.

  18. Reflective Coating on Fibrous Insulation for Reduced Heat Transfer

    NASA Technical Reports Server (NTRS)

    Hass, Derek D.; Prasad, B. Durga; Glass, David E.; Wiedemann, Karl E.

    1997-01-01

    Radiative heat transfer through fibrous insulation used in thermal protection systems (TPS) is significant at high temperatures (1200 C). Decreasing the radiative heat transfer through the fibrous insulation can thus have a major impact on the insulating ability of the TPS. Reflective coatings applied directly to the individual fibers in fibrous insulation should decrease the radiative heat transfer leading to an insulation with decreased effective thermal conductivity. Coatings with high infrared reflectance have been developed using sol-gel techniques. Using this technique, uniform coatings can be applied to fibrous insulation without an appreciable increase in insulation weight or density. Scanning electron microscopy, Fourier Transform infrared spectroscopy, and ellipsometry have been performed to evaluate coating performance.

  19. Constraining the age and magnitude of uplift in the northern National Petroleum Reserve in Alaska (NPRA)-apatite fission-track analysis of samples from three wells

    USGS Publications Warehouse

    Houseknecht, David W.; Bird, Kenneth J.; O'Sullivan, Paul

    2011-01-01

    A broad, post-mid-Cretaceous uplift is defined in the northern National Petroleum Reserve in Alaska (NPRA) by regional truncation of Cretaceous strata, thermal maturity patterns, and amounts of exhumation estimated from sonic logs. Apatite fission-track (AFT) analysis of samples from three wells (South Meade No. 1, Topagoruk No. 1, and Ikpikpuk No. 1) across the eastern flank of the uplift indicates Tertiary cooling followed by Quaternary heating. Results from all three wells indicate that cooling, presumably caused by uplift and erosion, started about 75-65 Ma (latest Cretaceous-earliest Tertiary) and continued through the Tertiary Period. Data from South Meade indicate more rapid cooling after about 35-15 Ma (latest Eocene-middle Miocene) followed by a significant increase in subsurface temperature during the Quaternary, probably the result of increased heat flow. Data from Topagoruk and Ikpikpuk include subtle evidence of accelerated cooling starting in the latest Eocene-middle Miocene and possible evidence of increased temperature during the Quaternary. Subsurface temperature perturbations related to the insulating effect of permafrost may have been responsible for the Quaternary temperature increase at Topagoruk and Ikpikpuk and may have been a contributing factor at South Meade. Multiple lines of geologic evidence suggest that the magnitude of exhumation resulting from uplift and erosion is 5,000-6,500 ft at South Meade, 4,000-5,500 ft at Topagoruk, and 2,500-4,000 ft at Ikpikpuk. The results from these wells help to define the broad geometry of the uplift, which increases in magnitude from less than 1,000 ft at the Colville River delta to perhaps more than 7,000 ft along the northwestern coast of NPRA, between Point Barrow and Peard Bay. Neither the origin nor the offshore extent of the uplift, west and north of the NPRA coast, have been determined.

  20. Beagle 2

    NASA Astrophysics Data System (ADS)

    Hall, D. S.; Pillinger, C. T.; Sims, M. R.; Pullan, D.; Whitehead, S.; Thatcher, J.; Clemmet, J.; Linguard, S.; Underwood, J.; Richter, L.

    2000-07-01

    Beagle 2 is the British-led lander of the ESA Mars Express mission. The prime objectives of Beagle 2 are to (1) search for criteria relating to past life on Mars, (2) seek trace atmospheric species indicative of extant life, (3) measure the detailed atmospheric composition to establish the geological history of the planet and to document the processes involved in seasonal climatic changes or diurnal cycling, (4) investigate the oxidative state of the Martian surface, rock interiors and beneath boulders, (5) examine the geological nature of the rocks, their chemistry, mineralogy, petrology and age, (6) characterise the geomorphology of the landing site, and (7) appraise the environmental conditions including temperature, pressure, wind speed, UV flux, etc. The entry system comprises a front shield/aeroshell, a back cover/bioshield and release mechanisms. The descent system depends on a mortar, pilot chute, main parachute and main parachute release mechanism. The Lander itself has a clam-like structure and lands cocooned within gas-filled airbags. The outer shell provides energy absorption and thermal insulation within a casing that must spread the impact loads and resists tearing. Many of the Beagle 2 science instruments are integrated with a robotic arm that transports them to deploy them in positions where they can study or obtain samples of the rocks and soil. Sub-surface samples are obtained using a Pluto (PLanetary Undersurface TOol) which has the ability to crawl across, and burrow below the planetary surface. The constraints placed on Beagle 2 by mass restrictions of the Mars Express mission has meant that many innovations are necessary to ensure delivery of a sufficient science payload mass capable of the full range of measurements necessary to achieve the mission objectives. In particular a highly integrated approach to lander sytems and science instruments has been essential. This approach and the necessary technology developments have important implications for future in-situ analyses of the Martian surface and sub-surface.

  1. Foot strike patterns and collision forces in habitually barefoot versus shod runners.

    PubMed

    Lieberman, Daniel E; Venkadesan, Madhusudhan; Werbel, William A; Daoud, Adam I; D'Andrea, Susan; Davis, Irene S; Mang'eni, Robert Ojiambo; Pitsiladis, Yannis

    2010-01-28

    Humans have engaged in endurance running for millions of years, but the modern running shoe was not invented until the 1970s. For most of human evolutionary history, runners were either barefoot or wore minimal footwear such as sandals or moccasins with smaller heels and little cushioning relative to modern running shoes. We wondered how runners coped with the impact caused by the foot colliding with the ground before the invention of the modern shoe. Here we show that habitually barefoot endurance runners often land on the fore-foot (fore-foot strike) before bringing down the heel, but they sometimes land with a flat foot (mid-foot strike) or, less often, on the heel (rear-foot strike). In contrast, habitually shod runners mostly rear-foot strike, facilitated by the elevated and cushioned heel of the modern running shoe. Kinematic and kinetic analyses show that even on hard surfaces, barefoot runners who fore-foot strike generate smaller collision forces than shod rear-foot strikers. This difference results primarily from a more plantarflexed foot at landing and more ankle compliance during impact, decreasing the effective mass of the body that collides with the ground. Fore-foot- and mid-foot-strike gaits were probably more common when humans ran barefoot or in minimal shoes, and may protect the feet and lower limbs from some of the impact-related injuries now experienced by a high percentage of runners.

  2. A national approach to diabetes foot risk stratification and foot care.

    PubMed

    Leese, G P; Stang, D; Pearson, D W

    2011-08-01

    The Scottish Diabetes Foot Action Group (SDG) has developed and introduced a national strategy plan for diabetic foot care across Scotland. This has involved the implementation of an evidence-based national foot screening and risk stratification programme that has already covered 61% of the population in just the first two years. Nationally agreed patient information foot leaflets and professional education material have been introduced, and a consensus for antibiotic use in the diabetic foot has been published. Information on multidisciplinary specialist foot services has been collected, indicating that 58% of Health Board areas have consultants with dedicated sessions in their job plan to a foot clinic, and 42% had integrated orthotic involvement. The SDG aims to increase these figures. Work has been undertaken to support local podiatry networks and improve communication between the specialist centre and the community. At a national level the SDG is working with Foot in Diabetes UK (FDUK) to recognize key podiatry skills by developing core competencies and a competency framework for the diabetes podiatrist and diabetes orthotist. The annual Scottish Diabetes Survey indicates some improvement in amputation rates with prevalence decreasing from 0.8% to 0.5%, and improved recording of foot ulceration at a national level. This national strategy has helped highlight the importance and difficulties facing diabetes foot care and should help to continue to improve the quality of care of people with diabetes who have foot-related problems.

  3. Conductivity Variation Observed by Polarization and Depolarization Current Measurements of High-Voltage Equipment Insulation System

    NASA Astrophysics Data System (ADS)

    Jamail, Nor Akmal Mohd; Piah, Mohamed Afendi Mohamed; Muhamad, Nor Asiah

    2012-09-01

    Nondestructive and time domain dielectric measurement techniques such as polarization and depolarization current (PDC) measurements have recently been widely used as a potential tool for determining high-voltage insulation conditions by analyzing the insulation conductivity. The variation in the conductivity of an insulator was found to depend on several parameters: the difference between the polarization and depolarization currents, geometric capacitance, and the relative permittivity of the insulation material. In this paper the conductivities of different types of oil-paper insulation material are presented. The insulation conductivities of several types of electrical apparatus were simulated using MATLAB. Conductivity insulation was found to be high at high polarizations and at the lowest depolarization current. It was also found to increase with increasing relative permittivity as well as with decreasing geometric capacitance of the insulating material.

  4. [Interactions of 1A2 insulator with promoter of hsp 70 gene in Drosophila melanogaster].

    PubMed

    Chetverina, D A; Elizar'ev, P V; Georgiev, P G; Erokhin, M M

    2013-04-01

    Insulators are regulatory DNA elements that participate in the modulation of the interactions between enhancers and promoters. Depending on the situation, insulators can either stabilize or destroy the contacts between enhancers and promoters. A possible explanation for the activity of insulators is their ability to directly interact with gene promoters. In the present study, it was demonstrated that, in model systems, a 1A2 insulator could interact with the core sequence of an hsp70 promoter. In this case, the insulator protein CP190 is found on the hsp70 promoter, which depends on the presence of an insulator in the transgene. The data obtained are consistent with the model, which implies that direct contacts between insulators and promoters make a considerable contribution to the modulation of the interactions between insulators and promoters.

  5. Multiple density layered insulator

    DOEpatents

    Alger, T.W.

    1994-09-06

    A multiple density layered insulator for use with a laser is disclosed which provides at least two different insulation materials for a laser discharge tube, where the two insulation materials have different thermoconductivities. The multiple layer insulation materials provide for improved thermoconductivity capability for improved laser operation. 4 figs.

  6. 14 CFR 25.856 - Thermal/Acoustic insulation materials.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Thermal/Acoustic insulation materials. 25....856 Thermal/Acoustic insulation materials. (a) Thermal/acoustic insulation material installed in the.../acoustic insulation materials (including the means of fastening the materials to the fuselage) installed in...

  7. Use of Several Thermal Analysis Techniques to Study the Cracking of an Nitrile Butadiene Rubber (NBR) Insulator on the Booster Separation Motor (BSM) of the Space Shuttle

    NASA Technical Reports Server (NTRS)

    Wingard, Charles D.; Whitaker, Ann F. (Technical Monitor)

    2000-01-01

    Two different vendor rubber formulations have been used to produce the silica-filled NBR insulators for the BSM used on both of the Solid Rocket Boosters (SRBs) of the Space Shuttle. A number of lots of the BSM insulator in 1998-99 exhibited surface cracks and/or crazing. Each insulator is bonded to the BSM aluminum aft closure with an epoxy adhesive. Induced insulator stresses from adhesive cure are likely greatest where the insulator/adhesive contour is the greatest, thus showing increased insulator surface cracking in this area. Thermal analysis testing by Dynamic Mechanical Analyzer (DMA) and Thermomechanical Analysis (TMA) was performed on one each of the two vendor BSM insulators previously bonded that exhibited the surface cracking. The TMA data from the film/fiber technique yielded the most meaningful results, with thin insulator surface samples containing cracks having roughly the same modulus (stiffness) as thin insulator bulk samples just underneath.

  8. Comparison of foot muscle morphology and foot kinematics between recreational runners with normal feet and with asymptomatic over-pronated feet.

    PubMed

    Zhang, Xianyi; Aeles, Jeroen; Vanwanseele, Benedicte

    2017-05-01

    Over-pronated feet are common in adults and are associated with lower limb injuries. Studying the foot muscle morphology and foot kinematic patterns is important for understanding the mechanism of over-pronation related injuries. The aim of this study is to compare the foot muscle morphology and foot inter-segmental kinematics between recreational runners with normal feet and those with asymptomatic over-pronated feet. A total of 26 recreational runners (17 had normal feet and 9 had over-pronated feet) participated in this study and their foot type was assessed using the 6-item Foot Posture Index. Selected foot muscles were scanned using an ultrasound device and the scanned images were processed to measure the thickness and cross-sectional area of the muscles. Muscles of interest include abductor hallucis, abductor digiti minimi, flexor digitorum brevis and longus, tibialis anterior and peroneus muscles. Foot kinematic data during walking was collected using a 3D motion capture system incorporating the Oxford Foot Model. The results show that individuals with over-pronated feet have larger size of abductor hallucis, flexor digitorum brevis and longus and smaller abductor digiti minimi than controls. Higher rearfoot peak eversion and forefoot peak supination during walking were observed in individuals with over-pronated feet. However, during gait the forefoot peak abduction was comparable. These findings indicate that in active asymptomatic individuals with over-pronated feet, the foot muscle morphology is adapted to increase control of the foot motion. The morphological characteristics of the foot muscles in asymptomatic individuals with over-pronated feet may affect their foot kinematics and benefit prevention from injuries. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. A methodological framework for detecting ulcers' risk in diabetic foot subjects by combining gait analysis, a new musculoskeletal foot model and a foot finite element model.

    PubMed

    Scarton, Alessandra; Guiotto, Annamaria; Malaquias, Tiago; Spolaor, Fabiola; Sinigaglia, Giacomo; Cobelli, Claudio; Jonkers, Ilse; Sawacha, Zimi

    2018-02-01

    Diabetic foot is one of the most debilitating complications of diabetes and may lead to plantar ulcers. In the last decade, gait analysis, musculoskeletal modelling (MSM) and finite element modelling (FEM) have shown their ability to contribute to diabetic foot prevention and suggested that the origin of the plantar ulcers is in deeper tissue layers rather than on the plantar surface. Hence the aim of the current work is to develop a methodology that improves FEM-derived foot internal stresses prediction, for diabetic foot prevention applications. A 3D foot FEM was combined with MSM derived force to predict the sites of excessive internal stresses on the foot. In vivo gait analysis data, and an MRI scan of a foot from a healthy subject were acquired and used to develop a six degrees of freedom (6 DOF) foot MSM and a 3D subject-specific foot FEM. Ankle kinematics were applied as boundary conditions to the FEM together with: 1. only Ground Reaction Forces (GRFs); 2. OpenSim derived extrinsic muscles forces estimated with a standard OpenSim MSM; 3. extrinsic muscle forces derived through the (6 DOF) foot MSM; 4. intrinsic and extrinsic muscles forces derived through the 6 DOF foot MSM. For model validation purposes, simulated peak pressures were extracted and compared with those measured experimentally. The importance of foot muscles in controlling plantar pressure distribution and internal stresses is confirmed by the improved accuracy in the estimation of the peak pressures obtained with the inclusion of intrinsic and extrinsic muscle forces. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Patients' perspectives on foot complications in type 2 diabetes: a qualitative study

    PubMed Central

    Gale, Lone; Vedhara, Kavita; Searle, Aidan; Kemple, Terry; Campbell, Rona

    2008-01-01

    Background Foot ulceration is a major health problem for people with diabetes. To minimise the risk of ulceration, patients are advised to perform preventive foot self-care. Aim To explore beliefs about diabetic foot complications and everyday foot self-care practices among people with type 2 diabetes. Design of study Qualitative study using one-to-one interviews. Setting A suburban primary care health centre. Method Semi-structured interviews with a purposive sample of adults with type 2 diabetes but with no experience of foot ulceration. Results Most participants were unsure of what a foot ulcer is and unaware of the difficulties associated with ulcer healing. Prevention of accidental damage to the skin was not considered a priority, as few participants knew that this is a common cause of foot ulceration. Although it was recognised that lower-limb amputation is more common in people with diabetes, this was perceived to be predominantly caused by poor blood supply to the feet and unrelated to foot ulceration. Therefore, preventive foot care focused on stimulating blood circulation, for example by walking barefoot. Consequently, some of the behaviours participants considered beneficial for foot health could potentially increase the risk of ulceration. In some cases the uptake of advice regarding preventive foot care was hampered because participants found it difficult to communicate with health professionals. Conclusion Patients with type 2 diabetes may have beliefs about foot complications that differ from medical evidence. Such illness beliefs may play a role in foot-related behaviours that have previously been unrecognised. Health professionals need to explore and address the beliefs underlying patients' foot self-care practices. PMID:18682014

  11. Investigations of Potential Phenotypes of Foot Osteoarthritis: Cross‐Sectional Analysis From the Clinical Assessment Study of the Foot

    PubMed Central

    Marshall, Michelle; Thomas, Martin J.; Menz, Hylton B.; Myers, Helen L.; Thomas, Elaine; Downes, Thomas; Peat, George; Roddy, Edward

    2016-01-01

    Objective To investigate the existence of distinct foot osteoarthritis (OA) phenotypes based on pattern of joint involvement and comparative symptom and risk profiles. Methods Participants ages ≥50 years reporting foot pain in the previous year were drawn from a population‐based cohort. Radiographs were scored for OA in the first metatarsophalangeal (MTP) joint, first and second cuneometatarsal, navicular first cuneiform, and talonavicular joints according to a published atlas. Chi‐square tests established clustering, and odds ratios (ORs) examined symmetry and pairwise associations of radiographic OA in the feet. Distinct underlying classes of foot OA were investigated by latent class analysis (LCA) and their association with symptoms and risk factors was assessed. Results In 533 participants (mean age 64.9 years, 55.9% female) radiographic OA clustered across both feet (P < 0.001) and was highly symmetrical (adjusted OR 3.0, 95% confidence interval 2.1, 4.2). LCA identified 3 distinct classes of foot OA: no or minimal foot OA (64%), isolated first MTP joint OA (22%), and polyarticular foot OA (15%). After adjustment for age and sex, polyarticular foot OA was associated with nodal OA, increased body mass index, and more pain and functional limitation compared to the other classes. Conclusion Patterning of radiographic foot OA has provided insight into the existence of 2 forms of foot OA: isolated first MTP joint OA and polyarticular foot OA. The symptom and risk factor profiles in individuals with polyarticular foot OA indicate a possible distinctive phenotype of foot OA, but further research is needed to explore the characteristics of isolated first MTP joint and polyarticular foot OA. PMID:26238801

  12. Patients With Diabetic Foot Disease Fear Major Lower-Extremity Amputation More Than Death.

    PubMed

    Wukich, Dane K; Raspovic, Katherine M; Suder, Natalie C

    2018-02-01

    The aim of this study was to identify the most-feared complications of diabetes mellitus (DM), comparing those with diabetic foot pathology with those without diabetic foot pathology. We determined the frequency of patients ranking major lower-extremity amputation (LEA) as their greatest fear in comparison to blindness, death, diabetic foot infection (DFI), or end-stage renal disease (ESRD) requiring dialysis. We further categorized the study group patients (N = 207) by their pathology such as diabetic foot ulcer (DFU), Charcot neuroarthropathy, foot infection, or acute neuropathic fractures and dislocations. The control group (N = 254) was comprised of patients with diabetes who presented with common non-diabetes-related foot pathology. A total of 461 patients were enrolled in this study and included 254 patients without diabetic foot complications and 207 patients with diabetic foot problems. When comparing patients with and without diabetic disease, no significant differences were observed with regard to their fear of blindness, DFI, or ESRD requiring dialysis. Patients with diabetic foot disease (61 of 207, 31.9%) were 136% more likely (odds ratio [OR] = 2.36; 95% CI = 1.51-3.70; P = .002] to rank major LEA as their greatest fear when compared with diabetic patients without foot disease (42 of 254, 16.5%) and were 49% less likely (OR = 0.51; 95% CI = 0.34-0.79; P = .002) to rank death as their greatest fear compared with patients without diabetic foot disease. Patients with diabetic foot pathology fear major LEA more than death, foot infection, or ESRD. Variables that were associated with ranking LEA as the greatest fear were the presence of a diabetic-related foot complication, duration of DM ≥10 years, insulin use, and the presence of peripheral neuropathy. Level II: Prospective, Case controlled study.

  13. Universal method for creating optically active nanostructures on layered materials

    NASA Astrophysics Data System (ADS)

    Kidd, Tim; He, Rui; Stollenwerk, Andrew; Oshea, Aaron; Beck, Ben; Spurgeon, Kyle; Gu, Genda

    2014-03-01

    We report a new method for the creating of nanostructures using a scanning electron microscope. Residual organic molecules on the surface of layered materials can be excited by electron beam radiation to burrow into the open spaces between the layers of these materials, and then are broken down further to form photoluminescent carbon nanoclusters. Surface characterization by atomic force microscopy shows the surface is nearly undamaged at the molecular level by this process, and a lack of nanostructure formation in non-layered materials confirms that the structures are created by sub-surface incorporation. The presence of carbon nanoclusters was determined by Raman Spectroscopy and photoluminescence in the visible light range. The nanostructures are react strongly to visible light, making them readily apparent using an optical microscope even for features measuring only a few nanometers tall. This technique can be used on apparently any layered material, with successful results on dichalcogenides, topological insulators, graphite, and high temperature copper oxide superconductors. This technique can create patterned nanostructures with vertical resolution at the nanometer scale and lateral resolution of tens of nanometers depending on beam spot size. This work is funded by University of Northern Iowa, NSF #DMR-1206530, and DOE #DE-AC02-98CH10886.

  14. Electronic structure of hydrogenated diamond: Microscopical insight into surface conductivity

    NASA Astrophysics Data System (ADS)

    Iacobucci, S.; Alippi, Paola; Calvani, P.; Girolami, M.; Offi, F.; Petaccia, L.; Trucchi, D. M.

    2016-07-01

    We have correlated the surface conductivity of hydrogen-terminated diamond to the electronic structure in the Fermi region. Significant density of electronic states (DOS) in proximity of the Fermi edge has been measured by photoelectron spectroscopy (PES) on surfaces exposed to air, corresponding to a p -type electric conductive regime, while upon annealing a depletion of the DOS has been achieved, resembling the diamond insulating state. The surface and subsurface electronic structure has been determined, exploiting the different probing depths of PES applied in a photon energy range between 7 and 31 eV. Ab initio density functional calculations including surface charge depletion and band-bending effects favorably compare with electronic states measured by angular-resolved photoelectron spectroscopy. Such states are organized in the energy-momentum space in a twofold structure: one, bulk-derived, band disperses in the Γ -X direction with an average hole effective mass of (0.43 ±0.02 ) m0 , where m0 is the bare electron mass; a second flatter band, with an effective mass of (2.2 ±0.9 ) m0 , proves that a hole gas confined in the topmost layers is responsible for the conductivity of the (2 ×1 ) hydrogen-terminated diamond (100 ) surface.

  15. Method for Implementing Subsurface Solid Derived Concentration Guideline Levels (DCGL) - 12331

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lively, J.W.

    2012-07-01

    The U.S. Nuclear Regulatory Commission (NRC) and other federal agencies currently approve the Multi-Agency Radiation Site Survey and Investigation Manual (MARSSIM) as guidance for licensees who are conducting final radiological status surveys in support of decommissioning. MARSSIM provides a method to demonstrate compliance with the applicable regulation by comparing residual radioactivity in surface soils with derived concentration guideline levels (DCGLs), but specifically discounts its applicability to subsurface soils. Many sites and facilities undergoing decommissioning contain subsurface soils that are potentially impacted by radiological constituents. In the absence of specific guidance designed to address the derivation of subsurface soil DCGLs andmore » compliance demonstration, decommissioning facilities have attempted to apply DCGLs and final status survey techniques designed specifically for surface soils to subsurface soils. The decision to apply surface soil limits and surface soil compliance metrics to subsurface soils typically results in significant over-excavation with associated cost escalation. MACTEC, Inc. has developed the overarching concepts and principles found in recent NRC decommissioning guidance in NUREG 1757 to establish a functional method to derive dose-based subsurface soil DCGLs. The subsurface soil method developed by MACTEC also establishes a rigorous set of criterion-based data evaluation metrics (with analogs to the MARSSIM methodology) that can be used to demonstrate compliance with the developed subsurface soil DCGLs. The method establishes a continuum of volume factors that relate the size and depth of a volume of subsurface soil having elevated concentrations of residual radioactivity with its ability to produce dose. The method integrates the subsurface soil sampling regime with the derivation of the subsurface soil DCGL such that a self-regulating optimization is naturally sought by both the responsible party and regulator. This paper describes the concepts and basis used by MACTEC to develop the dose-based subsurface soil DCGL method. The paper will show how MACTEC's method can be used to demonstrate that higher concentrations of residual radioactivity in subsurface soils (as compared with surface soils) can meet the NRC's dose-based regulations. MACTEC's method has been used successfully to obtain the NRC's radiological release at a site with known radiological impacts to subsurface soils exceeding the surface soil DCGL, saving both time and cost. Having considered the current NRC guidance for consideration of residual radioactivity in subsurface soils during decommissioning, MACTEC has developed a technically based approach to the derivation of and demonstration of compliance with subsurface soil DCGLs for radionuclides. In fact, the process uses the already accepted concepts and metrics approved for surface soils as the foundation for deriving scaling factors used to calculate subsurface soil DCGLs that are at least equally protective of the decommissioning annual dose standard. Each of the elements identified for consideration in the current NRC guidance is addressed in this proposed method. Additionally, there is considerable conservatism built into the assumptions and techniques used to arrive at subsurface soil scaling factors and DCGLs. The degree of conservatism embodied in the approach used is such that risk managers and decision makers approving and using subsurface soil DCGLs derived in accordance with this method can be confident that the future exposures will be well below permissible and safe levels. The technical basis for the method can be applied to a broad variety of sites with residual radioactivity in subsurface soils. Given the costly nature of soil surveys, excavation, and disposal of soils as low-level radioactive waste, MACTEC's method for deriving and demonstrating compliance with subsurface soil DCGLs offers the possibility of significant cost savings over the traditional approach of applying surface soil DCGLs to subsurface soils. Furthermore, while yet untested, MACTEC believes that the concepts and methods embodied in this approach could readily be applied to other types of contamination found in subsurface soils. (author)« less

  16. Flip-flop footwear with a moulded foot-bed for the treatment of foot pain: a randomised controlled trial.

    PubMed

    Chuter, Vivienne Helaine; Searle, Angela; Spink, Martin J

    2016-11-11

    Foot pain is a common problem affecting up to 1 in 5 adults and is known to adversely affect activities of daily living and health related quality of life. Orthopaedic footwear interventions are used as a conservative treatment for foot pain, although adherence is known to be low, in part due to the perception of poor comfort and unattractiveness of the footwear. The objective of this trial was to assess the efficacy of flip-flop style footwear (Foot Bio-Tec©) with a moulded foot-bed in reducing foot pain compared to participant's usual footwear. Two-arm parallel randomised controlled trial using computer generated random allocation schedule at an Australian university podiatry clinic. 108 volunteers with disabling foot pain were enrolled after responding to an advertisement and eligibility screening. Participants were randomly allocated to receive footwear education and moulded flip-flop footwear to wear as much as they were comfortable with for the next 12 weeks (n = 54) or footwear education and instructions to wear their normal footwear for the next 12 weeks (n = 54). Primary outcome was the pain domain of the Foot Health Status Questionnaire (FHSQ). Secondary outcomes were the foot function and general foot health domains of the FHSQ, a visual analogue scale (VAS) for foot pain and perceived comfort of the intervention footwear. Compared to the control group, the moulded flip-flop group showed a significant improvement in the primary outcome measure of the FHSQ pain domain (adjusted mean difference 8.36 points, 95 % CI 5.58 to 13.27, p < 0.01). Statistical and clinically significant differences were observed for the secondary measure of foot pain assessed by a VAS and the FSHQ domains of foot function and general foot health. None of the participants reported any pain or discomfort from the intervention footwear and six (footwear group = 4) were lost to follow up. Our results demonstrate that flip-flop footwear with a moulded foot-bed can have a significant effect on foot pain, function and foot health and might be a valuable adjunct therapy for people with foot pain. ACTRN12614000933651 . Retrospectively registered: 01/09/2014.

  17. 77 FR 21977 - Whitestone Power and Communications; Notice Concluding Pre-Filing Process and Approving Process...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-04-12

    ...) pontoon and a 34- foot-long, 3-foot-diameter HDPE pontoon; (3) a 100-kilowatt turbine/ generator unit; (4..., 16-foot- diameter Poncelet undershot water wheel; (2) a 34-foot-long, 19- to 24- foot-wide aluminum...

  18. A brief geological history of Cockspur Island at Fort Pulaski National Monument, Chatham County, Georgia

    USGS Publications Warehouse

    Swezey, Christopher S.; Seefelt, Ellen L.; Parker, Mercer

    2018-03-09

    Fort Pulaski National Monument is located on Cockspur Island in Chatham County, Georgia, within the Atlantic Coastal Plain province. The island lies near the mouth of the Savannah River, and consists of small mounds (hummocks), salt marshes, and sediment dredged from the river. A 1,017-foot (ft) (310-meter [m])-deep core drilled at Cockspur Island in 2010 by the U.S. Geological Survey revealed several sedimentary units ranging in age from 43 million years old to present. Sand and mud are present at drilling depths from 0 to 182 ft (56 m), limestone is present at depths from 182 ft (56 m) to 965 ft (295 m), and glauconitic sand is present at depths from 965 ft (295 m) to 1,017 ft (310 m). The limestone and the water within the limestone are referred to collectively as the Floridan aquifer system, which is the primary source of drinking water for the City of Savannah and surrounding communities. In addition to details of the subsurface geology, this fact sheet identifies the following geologic materials used in the construction of Fort Pulaski: (1) granite, (2) bricks, (3) sandstone, and (4) lime mud with oyster shells.

  19. Design, construction, operation, and evaluation of solar systems for industrial process-heat applications in the intermediate-temperature range (212/sup 0/F to 550/sup 0/F). Environmental assessment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    1982-01-01

    The environmental impacts are assessed for a proposed 50,000 square foot field of single axis tracking, concentrating solar collectors along the Ohio River in southern Ohio. The facility is planned to produce process steam for use in the production of polystyrene. Absorbed solar energy would heat an aliphatic hydrocarbon synthetic heat transfer fluid to a maximum temperature of 500/sup 0/F. The existing environment is briefly described, particularly regarding air quality. The potential environmental impacts of the solar process heat system on the air, water, soil, endangered species and archaeological and historical resources are examined, including risks due to flood andmore » glare and a comparison of alternatives. Also included are a Consent Judgment relating to two coal-fired boilers in violation of EPA regulations, property data of Gulf Synfluid 4CS (a candidate heat transfer fluid), piping and instrumentation diagrams and schematics, site grade and drainage plan, geological survey map, subsurface soil investigation, Ohio endangered species list, Ohio Archaeological Counsel certification list, and a study of heat transfer fluids and their properties. (LEW)« less

  20. Foot preferences in wild-living ring-necked parakeets (Psittacula krameri, Psittacidae).

    PubMed

    Randler, Christoph; Braun, Michael; Lintker, Stephanie

    2011-03-01

    Evidence for foot preferences has been reported in parrots and the majority of parrot species uses the left foot to hold and process food objects. Here we assessed the footedness of ring-necked parakeets (Psittacula krameri) in a wild-living non-native population in Heidelberg, Baden-Wurttemberg, Germany. Observations were made when parrots fed on catalpa trees Catalpa sp., with 20- to 50-cm-long fruits. Parakeets tend to bite off catalpa fruits with their beak, using one foot holding the fruit. Further, we established an experimental set-up (feeding location) and prepared pieces of apple in an adequate size to force parrots to handle the food with one foot. From 184 individuals feeding on the catalpa trees, 102 were recorded using the left foot and 82 the right foot. At the feeding location, 24 individuals were left-footed and 11 were right-footed. These observations suggest a foot preference in the ring-necked parakeet both on the population level and on the individual level.

  1. 16 CFR 1505.8 - Maximum acceptable material temperatures.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... heat-resistant properties, or if the insulation meets the thermal requirements. 4 40 less than melting... 105 insulation on windings or relays, solenoids, etc.: Thermocouple method 2 90 194 Resistance method 110 230 Class 130 insulation system 110 230 Insulation: Varnished-cloth insulation 85 185 Fiber used...

  2. 16 CFR 1505.8 - Maximum acceptable material temperatures.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... heat-resistant properties, or if the insulation meets the thermal requirements. 4 40 less than melting... 105 insulation on windings or relays, solenoids, etc.: Thermocouple method 2 90 194 Resistance method 110 230 Class 130 insulation system 110 230 Insulation: Varnished-cloth insulation 85 185 Fiber used...

  3. 16 CFR 1505.8 - Maximum acceptable material temperatures.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... heat-resistant properties, or if the insulation meets the thermal requirements. 4 40 less than melting... 105 insulation on windings or relays, solenoids, etc.: Thermocouple method 2 90 194 Resistance method 110 230 Class 130 insulation system 110 230 Insulation: Varnished-cloth insulation 85 185 Fiber used...

  4. 16 CFR 1505.8 - Maximum acceptable material temperatures.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... heat-resistant properties, or if the insulation meets the thermal requirements. 4 40 less than melting... 105 insulation on windings or relays, solenoids, etc.: Thermocouple method 2 90 194 Resistance method 110 230 Class 130 insulation system 110 230 Insulation: Varnished-cloth insulation 85 185 Fiber used...

  5. 75 FR 53963 - Iron Mask Hydro, LLC; Notice of Preliminary Permit Application Accepted for Filing and Soliciting...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-09-02

    ...-long upper dam made of either zoned earth and rockfill or concrete-face earth and rockfill; (2) a 50-foot-high, 950-foot-long earth-filled upper saddle dike A; (3) a 20-foot-high, 400-foot-long earth-filled upper saddle dike B; (4) a 40-foot-high, 6,559-foot-long lower embankment made of zoned earth or...

  6. 76 FR 74783 - Apache Hydro LLC; Notice of Preliminary Permit Application Accepted for Filing and Soliciting...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-12-01

    ... project would consist of the following: (1) A 210-foot-high, 1,610-foot-long earth fill dam; (2) a 20-foot... acre-foot storage capacity; (4) a 170-foot-high, 1,270.0-foot-long earth fill dam creating; (5) a lower... prior registration, using the eComment system at http://www.ferc.gov/docs-filing/ecomment.asp . You must...

  7. 78 FR 35018 - GB Energy Park, LLC; Notice of Preliminary Permit Application Accepted for Filing and Soliciting...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-06-11

    ... new 3,000-foot-long, 1,000-foot- wide, 50- to 75-foot-deep upper reservoir, with a surface area of 50...-foot-long, 1,000-foot- wide, 50- to 75-foot-deep lower reservoir with a surface area of 80 acres and a... instructions on the Commission's Web site http://www.ferc.gov/docs-filing/efiling.asp . Commenters can submit...

  8. Development and validation of a computational model to study the effect of foot constraint on ankle injury due to external rotation.

    PubMed

    Wei, Feng; Hunley, Stanley C; Powell, John W; Haut, Roger C

    2011-02-01

    Recent studies, using two different manners of foot constraint, potted and taped, document altered failure characteristics in the human cadaver ankle under controlled external rotation of the foot. The posterior talofibular ligament (PTaFL) was commonly injured when the foot was constrained in potting material, while the frequency of deltoid ligament injury was higher for the taped foot. In this study an existing multibody computational modeling approach was validated to include the influence of foot constraint, determine the kinematics of the joint under external foot rotation, and consequently obtain strains in various ligaments. It was hypothesized that the location of ankle injury due to excessive levels of external foot rotation is a function of foot constraint. The results from this model simulation supported this hypothesis and helped to explain the mechanisms of injury in the cadaver experiments. An excessive external foot rotation might generate a PTaFL injury for a rigid foot constraint, and an anterior deltoid ligament injury for a pliant foot constraint. The computational models may be further developed and modified to simulate the human response for different shoe designs, as well as on various athletic shoe-surface interfaces, so as to provide a computational basis for optimizing athletic performance with minimal injury risk.

  9. 75 FR 1276 - Requirements for Subsurface Safety Valve Equipment

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-01-11

    ...-0066] RIN 1010-AD45 Requirements for Subsurface Safety Valve Equipment AGENCY: Minerals Management... Edition of the American Petroleum Institute's Specification for Subsurface Safety Valve Equipment (API... 14A, Specification for Subsurface Safety Valve Equipment, Eleventh Edition, October 2005, Effective...

  10. Challenging the foundations of the clinical model of foot function: further evidence that the root model assessments fail to appropriately classify foot function.

    PubMed

    Jarvis, Hannah L; Nester, Christopher J; Bowden, Peter D; Jones, Richard K

    2017-01-01

    The Root model of normal and abnormal foot function remains the basis for clinical foot orthotic practice globally. Our aim was to investigate the relationship between foot deformities and kinematic compensations that are the foundations of the model. A convenience sample of 140 were screened and 100 symptom free participants aged 18-45 years were invited to participate. The static biomechanical assessment described by the Root model was used to identify five foot deformities. A 6 segment foot model was used to measure foot kinematics during gait. Statistical tests compared foot kinematics between feet with and without foot deformities and correlated the degree of deformity with any compensatory motions. None of the deformities proposed by the Root model were associated with distinct differences in foot kinematics during gait when compared to those without deformities or each other. Static and dynamic parameters were not correlated. Taken as part of a wider body of evidence, the results of this study have profound implications for clinical foot health practice. We believe that the assessment protocol advocated by the Root model is no longer a suitable basis for professional practice. We recommend that clinicians stop using sub-talar neutral position during clinical assessments and stop assessing the non-weight bearing range of ankle dorsiflexion, first ray position and forefoot alignments and movement as a means of defining the associated foot deformities. The results question the relevance of the Root assessments in the prescription of foot orthoses.

  11. Effects of Taping and Orthoses on Foot Biomechanics in Adults with Flat-Arched Feet.

    PubMed

    Bishop, Christopher; Arnold, John B; May, Thomas

    2016-04-01

    There is a paucity of evidence on the biomechanical effects of foot taping and foot orthoses in realistic conditions. This study aimed to determine the immediate effect and relationships between changes in multisegment foot biomechanics with foot taping and customized foot orthoses in adults with flat-arched feet. Multisegment foot biomechanics were measured in 18 adults with flat-arched feet (age 25.1 ± 2.8 yr; height 1.73 ± .13 m, body mass 70.3 ± 15.7 kg) during walking in four conditions in random order: neutral athletic shoe, neutral shoe with tape (low-Dye method and modified method) and neutral shoe with customized foot orthoses. In-shoe foot biomechanics were compared between conditions using a purpose developed foot model with three-dimensional kinematic analysis and inverse dynamics. Foot orthoses significantly delayed peak eversion compared to the neutral shoe (44% stance vs 39%, P = 0.002). Deformation across the midfoot and medial longitudinal arch was reduced with both the low-Dye taping (2.4°, P < 0.001) and modified taping technique (5.5°, P < 0.001). All interventions increased peak dorsiflexion of the first metatarsophalangeal joint (1.4°-3.2°, P < 0.001-0.023). Biomechanical responses to taping significantly predicted corresponding changes to foot orthoses (R2 = 0.08-0.52, P = 0.006 to <0.001). Foot orthoses more effectively altered timing of hindfoot motion whereas taping was superior in supporting the midfoot and medial longitudinal arch. The biomechanical response to taping was significantly related to the subsequent change observed with the use of foot orthoses.

  12. Age-related, interindividual, and right/left differences in anterior-posterior foot pressure ratio in preschool children

    PubMed Central

    2013-01-01

    Background This study aimed to examine age-related, interindividual, and right/left differences in anterior-posterior foot pressure ratio in 764 preschool children (364 boys and 400 girls) aged 3.5-6.5 years. Methods Subjects maintained an upright standing posture for 10 seconds on the Footview Clinic, an instrument designed to calculate the anterior-posterior foot pressure ratio. The ratio of anterior foot pressure in each subject’s right and left feet was selected as a variable, and the mean of a 10 s measurement was used for analysis. Results The ratio of anterior foot pressure was significantly larger in the right foot than in the left foot. With regard to age, the ratio of anterior foot pressure was significantly larger in children aged over 4.5 years than in children aged 3.5 years. It was also larger in children aged 6 and 6.5 years than in children aged 4 years. Interindividual differences in variables were large, and coefficients of variance were highest in children aged 3.5 years and lowest in children aged 6.5 years. Conclusions In conclusion, anterior foot pressure increases with age in preschool children. Interindividual differences in anterior foot pressure are large and tend to decrease with age. Furthermore, the anterior foot pressure is slightly higher in the right foot than in the left foot. These results will be useful for various studies, such as examining relationships between the anterior-posterior foot pressure ratio and factors, such as untouched toes, physical fitness, and level of exercise. PMID:23601375

  13. The immediate effects of foot orthoses on functional performance in individuals with patellofemoral pain syndrome.

    PubMed

    Barton, C J; Menz, H B; Crossley, K M

    2011-03-01

    Patellofemoral pain syndrome (PFPS) often results in reduced functional performance. There is growing evidence for the use of foot orthoses to treat this multifactorial condition. In this study, the immediate effects of foot orthoses on functional performance and the association of foot posture and footwear with improvements in function were evaluated. Fifty-two individuals with PFPS (18-35 years) were prescribed prefabricated foot orthoses (Vasyli Pro; Vasyli International, Labrador, Australia). Functional outcome measures evaluated included the change in (1) pain and (2) ease of a single-leg squat on a five-point Likert scale, and change in the number of (3) pain-free step downs and (4) single-leg rises from sitting. The association of foot posture using the Foot Posture Index, navicular drop and calcaneal angle relative to subtalar joint neutral; and the footwear motion control properties scale score with improved function were evaluated using Spearman's ρ statistics. Prefabricated foot orthoses produced significant improvements (p<0.05) for all functional outcome measures. A more pronated foot type and poorer footwear motion control properties were found to be associated with reduced pain during the single-leg squat and improvements in the number of pain-free single-leg rises from sitting when wearing foot orthoses. In addition, a more pronated foot type was also found to be associated with improved ease of completing a single-leg squat when wearing foot orthoses. Prefabricated foot orthoses provide immediate improvements in functional performance, and these improvements are associated with a more pronated foot type and poorer footwear motion control properties.

  14. Infrared Thermal Imaging for Automated Detection of Diabetic Foot Complications

    PubMed Central

    van Netten, Jaap J.; van Baal, Jeff G.; Liu, Chanjuan; van der Heijden, Ferdi; Bus, Sicco A.

    2013-01-01

    Background Although thermal imaging can be a valuable technology in the prevention and management of diabetic foot disease, it is not yet widely used in clinical practice. Technological advancement in infrared imaging increases its application range. The aim was to explore the first steps in the applicability of high-resolution infrared thermal imaging for noninvasive automated detection of signs of diabetic foot disease. Methods The plantar foot surfaces of 15 diabetes patients were imaged with an infrared camera (resolution, 1.2 mm/pixel): 5 patients had no visible signs of foot complications, 5 patients had local complications (e.g., abundant callus or neuropathic ulcer), and 5 patients had diffuse complications (e.g., Charcot foot, infected ulcer, or critical ischemia). Foot temperature was calculated as mean temperature across pixels for the whole foot and for specified regions of interest (ROIs). Results No differences in mean temperature >1.5 °C between the ipsilateral and the contralateral foot were found in patients without complications. In patients with local complications, mean temperatures of the ipsilateral and the contralateral foot were similar, but temperature at the ROI was >2 °C higher compared with the corresponding region in the contralateral foot and to the mean of the whole ipsilateral foot. In patients with diffuse complications, mean temperature differences of >3 °C between ipsilateral and contralateral foot were found. Conclusions With an algorithm based on parameters that can be captured and analyzed with a high-resolution infrared camera and a computer, it is possible to detect signs of diabetic foot disease and to discriminate between no, local, or diffuse diabetic foot complications. As such, an intelligent telemedicine monitoring system for noninvasive automated detection of signs of diabetic foot disease is one step closer. Future studies are essential to confirm and extend these promising early findings. PMID:24124937

  15. Infrared thermal imaging for automated detection of diabetic foot complications.

    PubMed

    van Netten, Jaap J; van Baal, Jeff G; Liu, Chanjuan; van der Heijden, Ferdi; Bus, Sicco A

    2013-09-01

    Although thermal imaging can be a valuable technology in the prevention and management of diabetic foot disease, it is not yet widely used in clinical practice. Technological advancement in infrared imaging increases its application range. The aim was to explore the first steps in the applicability of high-resolution infrared thermal imaging for noninvasive automated detection of signs of diabetic foot disease. The plantar foot surfaces of 15 diabetes patients were imaged with an infrared camera (resolution, 1.2 mm/pixel): 5 patients had no visible signs of foot complications, 5 patients had local complications (e.g., abundant callus or neuropathic ulcer), and 5 patients had diffuse complications (e.g., Charcot foot, infected ulcer, or critical ischemia). Foot temperature was calculated as mean temperature across pixels for the whole foot and for specified regions of interest (ROIs). No differences in mean temperature >1.5 °C between the ipsilateral and the contralateral foot were found in patients without complications. In patients with local complications, mean temperatures of the ipsilateral and the contralateral foot were similar, but temperature at the ROI was >2 °C higher compared with the corresponding region in the contralateral foot and to the mean of the whole ipsilateral foot. In patients with diffuse complications, mean temperature differences of >3 °C between ipsilateral and contralateral foot were found. With an algorithm based on parameters that can be captured and analyzed with a high-resolution infrared camera and a computer, it is possible to detect signs of diabetic foot disease and to discriminate between no, local, or diffuse diabetic foot complications. As such, an intelligent telemedicine monitoring system for noninvasive automated detection of signs of diabetic foot disease is one step closer. Future studies are essential to confirm and extend these promising early findings. © 2013 Diabetes Technology Society.

  16. New insulation attachment method eliminates compatibility bondline stresses

    NASA Technical Reports Server (NTRS)

    Schneider, W. C.

    1975-01-01

    Auger-shaped single-point fastener attaches rigid surface insulation tiles to orbiter shuttle spacecraft. Method can be used to bond wide variety of materials, including insulation, elastomers, and fibrous materials. Since insulation is attached at only one point, insulation and structure are free to form without inducing bond separation.

  17. 16 CFR § 1505.8 - Maximum acceptable material temperatures.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... heat-resistant properties, or if the insulation meets the thermal requirements. 4 40 less than melting... 105 insulation on windings or relays, solenoids, etc.: Thermocouple method 2 90 194 Resistance method 110 230 Class 130 insulation system 110 230 Insulation: Varnished-cloth insulation 85 185 Fiber used...

  18. Composite multilayer insulations for thermal protection of aerospace vehicles

    NASA Technical Reports Server (NTRS)

    Kourtides, Demetrius A.; Pitts, William C.

    1989-01-01

    Composite flexible multilayer insulation systems (MLI), consisting of alternating layers of metal foil and scrim cloth or insulation quilted together using ceramic thread, were evaluated for thermal performance and compared with a silica fibrous (baseline) insulation system. The systems studied included: (1) alternating layers of aluminoborosilicate (ABS) scrim cloth and stainless steel foil, with silica, ABS, or alumina insulation; (2) alternating layers of scrim cloth and aluminum foil, with silica or ABS insulation; (3) alternating layers of aluminum foil and silica or ABS insulation; and (4) alternating layers of aluminum-coated polyimide placed on the bottom of the silica insulation. The MLIs containing aluminum were the most efficient, measuring as little as half the backface temperature increase of the baseline system.

  19. Design and evaluation of thin metal surface insulation for hypersonic flight

    NASA Technical Reports Server (NTRS)

    Miller, R. C.; Petach, A. M.

    1976-01-01

    An all-metal insulation was studied as a thermal protection system for hypersonic vehicles. Key program goals included fabricating the insulation in thin packages which are optimized for high temperature insulation of an actively cooled aluminum structure, and the use of state-of-the-art alloys. The insulation was fabricated from 300 series stainless steel in thicknesses of 0.8 to 12 mm. The outer, 0.127 mm thick, skin was textured to accommodate thermal expansion and oxidized to increase emittance. The thin insulating package was achieved using an insulation concept consisting of foil radiation shields spaced within the package, and conical foil supports to carry loads from the skin and maintain package dimensions. Samples of the metal-insulation were tested to evaluate thermal insulation capability, rain and sand erosion resistance, high temperature oxidation resistance, applied load capability, and high temperature emittance.

  20. Tissue-Specific Regulation of Chromatin Insulator Function

    PubMed Central

    Matzat, Leah H.; Dale, Ryan K.; Moshkovich, Nellie; Lei, Elissa P.

    2012-01-01

    Chromatin insulators organize the genome into distinct transcriptional domains and contribute to cell type–specific chromatin organization. However, factors regulating tissue-specific insulator function have not yet been discovered. Here we identify the RNA recognition motif-containing protein Shep as a direct interactor of two individual components of the gypsy insulator complex in Drosophila. Mutation of shep improves gypsy-dependent enhancer blocking, indicating a role as a negative regulator of insulator activity. Unlike ubiquitously expressed core gypsy insulator proteins, Shep is highly expressed in the central nervous system (CNS) with lower expression in other tissues. We developed a novel, quantitative tissue-specific barrier assay to demonstrate that Shep functions as a negative regulator of insulator activity in the CNS but not in muscle tissue. Additionally, mutation of shep alters insulator complex nuclear localization in the CNS but has no effect in other tissues. Consistent with negative regulatory activity, ChIP–seq analysis of Shep in a CNS-derived cell line indicates substantial genome-wide colocalization with a single gypsy insulator component but limited overlap with intact insulator complexes. Taken together, these data reveal a novel, tissue-specific mode of regulation of a chromatin insulator. PMID:23209434

  1. High Performance Slab-on-Grade Foundation Insulation Retrofits

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Goldberg, Louise F.; Mosiman, Garrett E.

    ?A more accurate assessment of SOG foundation insulation energy savings than traditionally possible is now feasible. This has been enabled by advances in whole building energy simulation with 3-dimensional foundation modelling integration at each time step together with an experimental measurement of the site energy savings of SOG foundation insulation. Ten SOG insulation strategies were evaluated on a test building to identify an optimum retrofit insulation strategy in a zone 6 climate (Minneapolis, MN). The optimum insulation strategy in terms of energy savings and cost effectiveness consisted of two components: (a) R-20 XPS insulation above grade, and, (b) R-20 insulationmore » at grade (comprising an outer layer of R-10 insulation and an interior layer of R-12 poured polyurethane insulation) tapering to R-10 XPS insulation at half the below-grade wall height (the lower half of the stem wall was uninsulated). The optimum insulation strategy was applied to single and multi-family residential buildings in climate zone 4 - 7. The highest site energy savings of 5% was realized for a single family home in Duluth, MN, and the lowest savings of 1.4 % for a 4-unit townhouse in Richmond, VA. SOG foundation insulation retrofit simple paybacks ranged from 18 to 47 years. There are other benefits of SOG foundation insulation resulting from the increase in the slab surface temperatures. These include increased occupant thermal comfort, and a decrease in slab surface condensation particularly around the slab perimeter.« less

  2. Building America Case Study: Optimized Slab-on-Grade Foundation Insulation Retrofits, Madison, Wisconsin

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    A more accurate assessment of SOG foundation insulation energy savings than traditionally possible is now feasible. This has been enabled by advances in whole building energy simulation with 3-dimensional foundation modelling integration at each time step together with an experimental measurement of the site energy savings of SOG foundation insulation. Ten SOG insulation strategies were evaluated on a test building to identify an optimum retrofit insulation strategy in a zone 6 climate (Minneapolis, MN). The optimum insulation strategy in terms of energy savings and cost effectiveness consisted of two components: (a) R-20 XPS insulation above grade, and, (b) R-20 insulationmore » at grade (comprising an outer layer of R-10 insulation and an interior layer of R-12 poured polyurethane insulation) tapering to R-10 XPS insulation at half the below-grade wall height (the lower half of the stem wall was uninsulated). The optimum insulation strategy was applied to single and multi-family residential buildings in climate zone 4 - 7. The highest site energy savings of 5% was realized for a single family home in Duluth, MN, and the lowest savings of 1.4 percent for a 4-unit townhouse in Richmond, VA. SOG foundation insulation retrofit simple paybacks ranged from 18 to 47 years. There are other benefits of SOG foundation insulation resulting from the increase in the slab surface temperatures. These include increased occupant thermal comfort, and a decrease in slab surface condensation particularly around the slab perimeter.« less

  3. Measurement system for 3-D foot coordinates and parameters

    NASA Astrophysics Data System (ADS)

    Liu, Guozhong; Li, Yunhui; Wang, Boxiong; Shi, Hui; Luo, Xiuzhi

    2008-12-01

    The 3-D foot-shape measurement system based on laser-line-scanning principle and the model of the measurement system were presented. Errors caused by nonlinearity of CCD cameras and caused by installation can be eliminated by using the global calibration method for CCD cameras, which based on nonlinear coordinate mapping function and the optimized method. A local foot coordinate system is defined with the Pternion and the Acropodion extracted from the boundaries of foot projections. The characteristic points can thus be located and foot parameters be extracted automatically by the local foot coordinate system and the related sections. Foot measurements for about 200 participants were conducted and the measurement results for male and female participants were presented. 3-D foot coordinates and parameters measurement makes it possible to realize custom-made shoe-making and shows great prosperity in shoe design, foot orthopaedic treatment, shoe size standardization, and establishment of a feet database for consumers.

  4. [Foot growth and foot types in children and adolescents: a narrative review].

    PubMed

    Xu, Miaomiao; Wang, Lin

    2017-08-01

    Foot shape and size are important for footwear design and production. Information about important foot characteristics helps not only to improve shoe comfort but to maintain the proper physiological development of the feet. What's more, plenty of studies have suggested that the shape of the shoe must closely resemble the shape of the foot to create a properly fitted shoe. This means that the differences between various populations should be considered and that footwear should be designed according to the measurements of users. Childhood and adolescent are important periods of human growth. During these periods, foot shape changes with human growth and can be influenced by extrinsic factors. Therefore, the foot shape characteristics of children and adolescents should be investigated. The results from these investigations can contribute to developing appropriate shoe for children and adolescents, improving perceived comfort of children shoes and preventing pedopathy among children and adolescents. This review aims to discuss measuring methods of foot shape, types of foot shape, and factors influencing foot shape. The results of the review can provide recommendations for investigating growth development of foot shape and useful information for consumers and shoe manufacturers.

  5. Proper shoe sizes for Thai elderly.

    PubMed

    Chaiwanichsiri, Dootchai; Tantisiriwat, Natthiya; Janchai, Siriporn

    2008-12-01

    Problems from improper shoe fitting are common, but there are limited foot data for the older Thai population. To study foot dimensions and determine proper shoe sizes for Thai elderly. Healthy older people: 108 men, 105 women, aged 60-80 years, who were independent in walking, were recruited. Thirteen foot dimensions and current shoes used were measured. Side-to-side, gender difference, and correlations of main foot measurements were analyzed. About 50% women and 34% men wore too narrow shoes, and this was found to be associated with foot pain. At the same foot length (FL), men had larger foot width (FW) and toe depth. Foot width=2.39+(0.29 x FL), r=0.50, p=0.001 for women and=2.48+(0.31 x FL), r=0.56, p=0.002 for men. Arch length=1.0+(0.7 x FL), r=0.93, p=0.001 for both genders. Toe depth had constant values in all shoe sizes of each gender. Correlations of other foot parameters were reported. These anthropometric data is essential for proper shoe fitting in order to provide foot ergonomics and prevent foot problems for older Thai people.

  6. Relationship between static foot posture and foot mobility

    PubMed Central

    2011-01-01

    Background It is not uncommon for a person's foot posture and/or mobility to be assessed during a clinical examination. The exact relationship, however, between static posture and mobility is not known. Objective The purpose of this study was to determine the degree of association between static foot posture and mobility. Method The static foot posture and foot mobility of 203 healthy individuals was assessed and then analyzed to determine if low arched or "pronated" feet are more mobile than high arched or "supinated" feet. Results The study demonstrated that those individuals with a lower standing dorsal arch height and/or a wider standing midfoot width had greater mobility in their foot. In addition, those individuals with higher Foot Posture Index (FPI) values demonstrated greater mobility and those with lower FPI values demonstrated less mobility. Finally, the amount of foot mobility that an individual has can be predicted reasonably well using either a 3 or 4 variable linear regression model. Conclusions Because of the relationship between static foot posture and mobility, it is recommended that both be assessed as part of a comprehensive evaluation of a individual with foot problems. PMID:21244705

  7. A new podiatry service for patients with arthritis.

    PubMed

    Rome, Keith; Erikson, Kathryn; Ng, Anthony; Gow, Peter J; Sahid, Hazra; Williams, Anita E

    2013-03-01

    The aims of this study were to identify the impact of a new podiatric rheumatology service on reducing foot pain, impairment and disability in patients with foot problems associated with rheumatic disease, and to report on patient satisfaction with the service. A retrospective study of 245 patients with rheumatic disease at Counties Manukau DHB was conducted. Foot pain, impairment and disability were measured using a self-reporting patient outcome measure, the Foot Function Index. A range of podiatric interventions were reported. A self-administered, postal patient satisfaction questionnaire was sent to 148 patients. Over two-thirds of patients were observed with hallux valgus (bunions). The results demonstrate a significant reduction in foot pain (p<0.001) from initial visit to second visit (18% reduction in pain). A significant decrease in foot disability (p=0.04) was found from initial visit to second visit. No significant differences were seen with foot impairment (p=0.78). A variety of intervention measures were used with 24% of patients being prescribed foot orthoses and 28% of patients given footwear advice. The patient satisfaction survey found 84% of patients reported they were satisfied with the new service and 80% of patients reported that the service helped with their foot problems. The current service meets the needs of patients who suffer from rheumatological foot conditions such as rheumatoid arthritis and gout. The need for good foot education, provision of foot orthoses and advice on footwear are crucial to reduce the burden on patients with rheumatological foot conditions.

  8. The effects of prolonged running on foot posture: a repeated measures study of half marathon runners using the foot posture index and navicular height

    PubMed Central

    2013-01-01

    Background Different foot postures are associated with alterations in foot function, kinetics and the subsequent occurrence of injury. Little is known about changes in foot posture following prolonged weightbearing exercise. This study aimed to identify changes in foot posture after running a half marathon. Methods Foot posture was measured using the Foot Posture Index (FPI-6) and navicular height in thirty volunteer participants before and after running a half marathon. FPI-6 scores were converted to Rasch logit values and means compared for these and navicular height using an ANOVA. Results There was a 5 mm drop in navicular height in both feet when measured after the half marathon (P < 0.05). The FPI-6 showed a side x time interaction with an increase in score indicating a more ‘pronated’ position in the left foot of + 2 [Rasch value + 1.7] but no change in the right foot (+ 0.4 [+ 0.76]) following the half marathon. Conclusion The apparent differences between the FPI-6 and navicular height on the right foot may be because the FPI-6 takes soft tissue contour changes into consideration whilst the navicular height focuses on skeletal changes. The changes in foot posture towards a more pronated position may have implications for foot function, and therefore risk of injury; shoe fit and comfort and also the effect of therapeutic orthoses worn during prolonged running. PMID:23705863

  9. Bipedal gait model for precise gait recognition and optimal triggering in foot drop stimulator: a proof of concept.

    PubMed

    Shaikh, Muhammad Faraz; Salcic, Zoran; Wang, Kevin I-Kai; Hu, Aiguo Patrick

    2018-03-10

    Electrical stimulators are often prescribed to correct foot drop walking. However, commercial foot drop stimulators trigger inappropriately under certain non-gait scenarios. Past researches addressed this limitation by defining stimulation control based on automaton of a gait cycle executed by foot drop of affected limb/foot only. Since gait is a collaborative activity of both feet, this research highlights the role of normal foot for robust gait detection and stimulation triggering. A novel bipedal gait model is proposed where gait cycle is realized as an automaton based on concurrent gait sub-phases (states) from each foot. The input for state transition is fused information from feet-worn pressure and inertial sensors. Thereafter, a bipedal gait model-based stimulation control algorithm is developed. As a feasibility study, bipedal gait model and stimulation control are evaluated in real-time simulation manner on normal and simulated foot drop gait measurements from 16 able-bodied participants with three speed variations, under inappropriate triggering scenarios and with foot drop rehabilitation exercises. Also, the stimulation control employed in commercial foot drop stimulators and single foot gait-based foot drop stimulators are compared alongside. Gait detection accuracy (98.9%) and precise triggering under all investigations prove bipedal gait model reliability. This infers that gait detection leveraging bipedal periodicity is a promising strategy to rectify prevalent stimulation triggering deficiencies in commercial foot drop stimulators. Graphical abstract Bipedal information-based gait recognition and stimulation triggering.

  10. Evaluation of the effect of nurse education on patient-reported foot checks and foot care behaviour of people with diabetes receiving haemodialysis.

    PubMed

    Brand, S L; Musgrove, A; Jeffcoate, W J; Lincoln, N B

    2016-02-01

    To assess whether a programme of nurse education increased the frequency with which nurses conducted foot checks on people with diabetes undergoing haemodialysis and to evaluate whether this influenced self-reported foot care behaviour. A non-randomized stepped-wedge design was used to evaluate a nurse education programme implemented in four UK National Health Service dialysis units. People with diabetes undergoing haemodialysis were invited to complete a questionnaire on the frequency of foot examination by health professionals, on the presence of foot problems and on their own foot care behaviour, using the Nottingham Assessment of Functional Foot-care (NAFF). An education session for nurses, including procedures for foot examination, was conducted sequentially in each of four haemodialysis units. The questionnaire was repeated at 2-monthly intervals. The education session resulted in a significant increase in the reported number of foot examinations by nurses (P = 0.007). There was also a significant improvement in reported foot care behaviour (P < 0.001), but this occurred between the first and second 2-monthly assessments and was unrelated to the timing of the intervention. A single education session can improve the routine checking of the feet of people with diabetes undergoing haemodialysis. The administration of the Nottingham Assessment of Functional Foot-care questionnaire was associated with improved self-reported foot care behaviour, reflecting greater awareness of risk in this population. © 2015 The Authors. Diabetic Medicine © 2015 Diabetes UK.

  11. Bipedal vs. unipedal: a comparison between one-foot and two-foot driving in a driving simulator.

    PubMed

    Wang, Dong-Yuan Debbie; Richard, F Dan; Cino, Cullen R; Blount, Trevin; Schmuller, Joseph

    2017-04-01

    Is it better to drive with one foot or with two feet? Although two-foot driving has fostered interminable debate in the media, no scientific and systematic research has assessed this issue and federal and local state governments have provided no answers. The current study compared traditional unipedal (one-foot driving, using the right foot to control the accelerator and the brake pedal) with bipedal (two-foot driving, using the right foot to control the accelerator and the left foot to control the brake pedal) responses to a visual stimulus in a driving simulator study. Each of 30 undergraduate participants drove in a simulated driving scenario. They responded to a STOP sign displayed on the centre of the screen by bringing their vehicle to a complete stop. Brake RT was shorter under the bipedal condition, while throttle RT showed advantage under the unipedal condition. Stopping time and distance showed a bipedal advantage, however. We discuss further limitations of the current study and implications in a driving task. Before drawing any conclusions from the simulator study, further on-road driving tests are necessary to confirm these obtained bipedal advantages. Practitioner Summary: Traditional unipedal (using the right foot to control the accelerator and the brake pedal) with bipedal (using the right foot to control the accelerator and the left foot to control the brake pedal) responses to a visual stimulus in a driving simulator were compared. Our results showed a bipedal advantage. Promotion: Although two-foot driving has fostered interminable debate in the media, no scientific and systematic research has assessed this issue and federal and local state governments have provided no answers. Traditional (one-foot driving, using the right foot to control the accelerator and the brake pedal) with bipedal (using the right foot to control the accelerator and the left foot to control the brake pedal) responses to a visual stimulus in a simulated driving study were compared. Throttle reaction time was faster in the unipedal condition whereas brake reaction time, stopping time and stopping distance showed a bipedal advantage. We discuss further theoretical issues and implications in a driving task.

  12. Preliminary investigation of foot pressure distribution variation in men and women adults while standing.

    PubMed

    Periyasamy, R; Mishra, A; Anand, Sneh; Ammini, A C

    2011-09-01

    Women and men are anatomically and physiologically different in a number of ways. They differ in both shape and size. These differences could potentially mean foot pressure distribution variation in men and women. The purpose of this study was to analyze standing foot pressure image to obtain the foot pressure distribution parameter - power ratio variation between men and women using image processing in frequency domain. We examined 28 healthy adult subjects (14 men and 14 women) aged between 20 and 45 years was recruited for our study. Foot pressure distribution patterns while standing are obtained by using a PedoPowerGraph plantar pressure measurement system for foot image formation, a digital camera for image capturing, a TV tuner PC-add on card, a WinDvr software for still capture and Matlab software with dedicated image processing algorithms have been developed. Various PedoPowerGraphic parameters such as percentage medial impulse (PMI), fore foot to hind foot pressure distribution ratio (F/H), big toe to fore foot pressure distribution ratio (B/F) and power ratio (PR) were evaluated. In men, contact area was significantly larger in all regions of the foot compared with women. There were significant differences in plantar pressure distribution but there was no significant difference in F/H and B/F ratio. Mean PR value was significantly greater in men than women under the hind foot and fore foot. PMI value was greater in women than men. As compared to men, women have maximum PR variations in the mid foot. Hence there is significant difference at level p<0.05 in medial mid foot and mid foot PR of women as compared to men. There was variation in plantar pressure distribution because the contact area of the men foot was larger than that of women foot. Hence knowledge of pressure distributions variation of both feet can provide suitable guidelines to biomedical engineers and doctor for designing orthotic devices for reliving the area of excessively high pressure. Copyright © 2011 Elsevier Ltd. All rights reserved.

  13. A cross-sectional observational study comparing foot and ankle characteristics in people with stroke and healthy controls.

    PubMed

    Kunkel, Dorit; Potter, Julia; Mamode, Louis

    2017-06-01

    The purpose of this study was to explore and compare foot and ankle characteristics in people with stroke and healthy controls; and between stroke fallers and non-fallers. Participants were recruited from community groups and completed standardized tests assessing sensation, foot posture, foot function, ankle dorsiflexion and first metatarsal phalangeal joint range of motion (1st MPJ ROM), hallux valgus presence and severity. Twenty-three stroke participants (mean age 75.09 ± 7.57 years; 12 fallers) and 16 controls (mean age 73.44 ± 8.35 years) took part. Within the stroke group, reduced 1st MPJ sensation (p = 0.016) and 1st MPJ ROM (p = 0.025) were observed in the affected foot in comparison to the non-affected foot; no other differences were apparent. Pooled data (for both feet) was used to explore between stroke/control (n = 78 feet) and stroke faller/non-faller (n = 46 feet) group differences. In comparison to the control group, stroke participants exhibited reduced sensation of the 1st MPJ (p = 0.020), higher Foot Posture Index scores (indicating greater foot pronation, p = 0.008) and reduced foot function (p = 0.003). Stroke fallers exhibited significantly greater foot pronation in comparison to non-fallers (p = 0.027). Results indicated differences in foot and ankle characteristics post stroke in comparison to healthy controls. These changes may negatively impact functional ability and the ability to preserve balance. Further research is warranted to explore the influence of foot problems on balance ability and falls in people with stroke. Implications for Rehabilitation Foot problems are common post stroke. As foot problems have been linked to increased fall risk among the general population we recommend that it would be beneficial to include foot and ankle assessments or a referral to a podiatrist for people with stroke who report foot problems. Further research is needed to explore if we can improve functional performance post stroke and reduce fall risk if treatment or prevention of foot problems can be included in stroke rehabilitation.

  14. Class III Mid-Term Project, "Increasing Heavy Oil Reserves in the Wilmington Oil Field Through Advanced Reservoir Characterization and Thermal Production Technologies"

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Scott Hara

    2007-03-31

    The overall objective of this project was to increase heavy oil reserves in slope and basin clastic (SBC) reservoirs through the application of advanced reservoir characterization and thermal production technologies. The project involved improving thermal recovery techniques in the Tar Zone of Fault Blocks II-A and V (Tar II-A and Tar V) of the Wilmington Field in Los Angeles County, near Long Beach, California. A primary objective has been to transfer technology that can be applied in other heavy oil formations of the Wilmington Field and other SBC reservoirs, including those under waterflood. The first budget period addressed several producibilitymore » problems in the Tar II-A and Tar V thermal recovery operations that are common in SBC reservoirs. A few of the advanced technologies developed include a three-dimensional (3-D) deterministic geologic model, a 3-D deterministic thermal reservoir simulation model to aid in reservoir management and subsequent post-steamflood development work, and a detailed study on the geochemical interactions between the steam and the formation rocks and fluids. State of the art operational work included drilling and performing a pilot steam injection and production project via four new horizontal wells (2 producers and 2 injectors), implementing a hot water alternating steam (WAS) drive pilot in the existing steamflood area to improve thermal efficiency, installing a 2400-foot insulated, subsurface harbor channel crossing to supply steam to an island location, testing a novel alkaline steam completion technique to control well sanding problems, and starting on an advanced reservoir management system through computer-aided access to production and geologic data to integrate reservoir characterization, engineering, monitoring, and evaluation. The second budget period phase (BP2) continued to implement state-of-the-art operational work to optimize thermal recovery processes, improve well drilling and completion practices, and evaluate the geomechanical characteristics of the producing formations. The objectives were to further improve reservoir characterization of the heterogeneous turbidite sands, test the proficiency of the three-dimensional geologic and thermal reservoir simulation models, identify the high permeability thief zones to reduce water breakthrough and cycling, and analyze the nonuniform distribution of the remaining oil in place. This work resulted in the redevelopment of the Tar II-A and Tar V post-steamflood projects by drilling several new wells and converting idle wells to improve injection sweep efficiency and more effectively drain the remaining oil reserves. Reservoir management work included reducing water cuts, maintaining or increasing oil production, and evaluating and minimizing further thermal-related formation compaction. The BP2 project utilized all the tools and knowledge gained throughout the DOE project to maximize recovery of the oil in place.« less

  15. New Properties of Drosophila scs and scs’ Insulators

    PubMed Central

    Kyrchanova, Olga; Leman, Dmitry; Parshikov, Alexander; Fedotova, Anna; Studitsky, Vasily; Maksimenko, Oksana; Georgiev, Pavel

    2013-01-01

    Insulators are defined as a class of regulatory elements that delimit independent transcriptional domains within eukaryotic genomes. The first insulators to be identified were scs and scs', which flank the domain including two heat shock 70 genes. Zw5 and BEAF bind to scs and scs', respectively, and are responsible for the interaction between these insulators. Using the regulatory regions of yellow and white reporter genes, we have found that the interaction between scs and scs' improves the enhancer-blocking activity of the weak scs' insulator. The sequences of scs and scs' insulators include the promoters of genes that are strongly active in S2 cells but not in the eyes, in which the enhancer-blocking activity of these insulators has been extensively examined. Only the promoter of the Cad87A gene located at the end of the scs insulator drives white expression in the eyes, and the white enhancer can slightly stimulate this promoter. The scs insulator contains polyadenylation signals that may be important for preventing transcription through the insulator. As shown previously, scs and scs' can insulate transcription of the white transgene from the enhancing effects of the surrounding genome, a phenomenon known as the chromosomal position effect (CPE). After analyzing many independent transgenic lines, we have concluded that transgenes carrying the scs insulator are rarely inserted into genomic regions that stimulate the white reporter expression in the eyes. PMID:23638134

  16. Interaction between a pair of gypsy insulators or between heterologous gypsy and Wari insulators modulates Flp site-specific recombination in Drosophila melanogaster.

    PubMed

    Krivega, Margarita; Savitskaya, Ekaterina; Krivega, Ivan; Karakozova, Marina; Parshikov, Aleksander; Golovnin, Anton; Georgiev, Pavel

    2010-08-01

    Chromatin insulators block the action of transcriptional enhancers when interposed between an enhancer and a promoter. An Flp technology was used to examine interactions between Drosophila gypsy and Wari insulators in somatic and germ cells. The gypsy insulator consists of 12 binding sites for the Su(Hw) protein, while the endogenous Wari insulator, located on the 3' side of the white gene, is independent from the Su(Hw) protein. Insertion of the gypsy but not Wari insulator between FRT sites strongly blocks recombination between Flp dimers bound to FRT sites located on the same chromatid (recombination in cis) or in sister chromatids (unequal recombination in trans). At the same time, the interaction between Wari and gypsy insulators regulates the efficiency of Flp-mediated recombination. Thus, insulators may have a role in controlling interactions between distantly located protein complexes (not only those involved in transcriptional gene regulation) on the same chromosome or on sister chromatids in somatic and germ cells. We have also found that the frequency of Flp-mediated recombination between FRT sites is strongly dependent on the relative orientation of gypsy insulators. Taken together, our results indicate that the interactions between insulators can be visualized by Flp technology and that insulators may be involved in blocking undesirable interactions between proteins at the two-chromatid phase of the cell cycle.

  17. Automatic identification and location technology of glass insulator self-shattering

    NASA Astrophysics Data System (ADS)

    Huang, Xinbo; Zhang, Huiying; Zhang, Ye

    2017-11-01

    The insulator of transmission lines is one of the most important infrastructures, which is vital to ensure the safe operation of transmission lines under complex and harsh operating conditions. The glass insulator often self-shatters but the available identification methods are inefficient and unreliable. Then, an automatic identification and localization technology of self-shattered glass insulators is proposed, which consists of the cameras installed on the tower video monitoring devices or the unmanned aerial vehicles, the 4G/OPGW network, and the monitoring center, where the identification and localization algorithm is embedded into the expert software. First, the images of insulators are captured by cameras, which are processed to identify the region of insulator string by the presented identification algorithm of insulator string. Second, according to the characteristics of the insulator string image, a mathematical model of the insulator string is established to estimate the direction and the length of the sliding blocks. Third, local binary pattern histograms of the template and the sliding block are extracted, by which the self-shattered insulator can be recognized and located. Finally, a series of experiments is fulfilled to verify the effectiveness of the algorithm. For single insulator images, Ac, Pr, and Rc of the algorithm are 94.5%, 92.38%, and 96.78%, respectively. For double insulator images, Ac, Pr, and Rc are 90.00%, 86.36%, and 93.23%, respectively.

  18. Electrical Resistance Tomography Field Trials to Image CO2 Sequestration

    NASA Astrophysics Data System (ADS)

    Newmark, R.

    2003-12-01

    If geologic formations are used to sequester or store carbon dioxide (CO2) for long periods of time, it will be necessary to verify the containment of injected CO2 by assessing leaks and flow paths, and by understanding the geophysical and geochemical interactions between the CO2 and the geologic minerals and fluids. Remote monitoring methods are preferred, to minimize cost and impact to the integrity of the disposal reservoir. Electrical methods are especially well suited for monitoring processes involving fluids, as electrical properties are most sensitive to the presence and nature of the fluids contained in the medium. High resolution tomographs of electrical properties have been used with success for site characterization, monitoring subsurface migration of fluids in instances of leaking underground tanks, water infiltration events, subsurface steam floods, contaminant movement, and assessing the integrity of subsurface barriers. These surveys are commonly conducted utilizing vertical arrays of point electrodes in a crosswell configuration. Alternative ways of monitoring the reservoir are desirable due to the high costs of drilling the required monitoring boreholes Recent field results obtained using steel well casings as long electrodes are also promising. We have conducted field trials to evaluate the effectiveness of long electrode ERT as a potential monitoring approach for CO2 sequestration. In these trials, CO2 is not being sequestered but rather is being used as a solvent for enhanced oil recovery. This setting offers the same conditions expected during sequestration so monitoring secondary oil recovery allows a test of the method under realistic physical conditions and operational constraints. Field experience has confirmed the challenges identified during model studies. The principal difficulty are the very small signals due to the fact that formation changes occur only over a small segment of the 5000 foot length of the electrodes. In addition, telluric noise can be comparable to the signal levels during periods of geomagnetic activity. Finally, instrumentation stability over long periods is necessary to follow trends in reservoir behavior for several years. Solutions to these and other problems will be presented along with results from the first two years of work at a producing field undergoing CO2 flood. If electrical resistance tomography (ERT) imaging can be performed using existing well casings as long electrodes, it will substantially reduce the cost to monitor CO2 sequestration. This work was performed under the auspices of the U.S. Department of Energy by University of California Lawrence Livermore National Laboratory under contract No. W-7405-Eng-48.

  19. Introduction to Insulation. Introduction to Construction Series. Instructor Edition.

    ERIC Educational Resources Information Center

    Associated General Contractors of America, Washington, DC.

    This module on introductory insulation is one of a series of modules designed to teach basic skills necessary for entry-level employment in this field. The instructor's guide contains three instructional units that cover the following topics: (1) insulation materials; (2) insulation tools; and (3) insulation layout and basic skills. Each…

  20. 49 CFR 178.57 - Specification 4L welded insulated cylinders.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... cylinder must be insulated. The insulating material must be fire resistant. The insulation on non-evacuated.... If a vacuum is maintained in the insulation space, the evacuated jacket must be designed for a... must be such that the total heat transfer, from the atmosphere at ambient temperature to the contents...

  1. 49 CFR 178.57 - Specification 4L welded insulated cylinders.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... cylinder must be insulated. The insulating material must be fire resistant. The insulation on non-evacuated.... If a vacuum is maintained in the insulation space, the evacuated jacket must be designed for a... must be such that the total heat transfer, from the atmosphere at ambient temperature to the contents...

  2. 49 CFR 178.57 - Specification 4L welded insulated cylinders.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... cylinder must be insulated. The insulating material must be fire resistant. The insulation on non-evacuated.... If a vacuum is maintained in the insulation space, the evacuated jacket must be designed for a... must be such that the total heat transfer, from the atmosphere at ambient temperature to the contents...

  3. 49 CFR 236.108 - Insulation resistance tests, wires in trunking and cables.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false Insulation resistance tests, wires in trunking and... Insulation resistance tests, wires in trunking and cables. (a) Insulation resistance of wires and cables, except wires connected directly to track rails, shall be tested when wires, cables, and insulation are...

  4. 49 CFR 236.108 - Insulation resistance tests, wires in trunking and cables.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Insulation resistance tests, wires in trunking and... Insulation resistance tests, wires in trunking and cables. (a) Insulation resistance of wires and cables, except wires connected directly to track rails, shall be tested when wires, cables, and insulation are...

  5. 24 CFR 200.949 - Building product standards and certification program for exterior insulated steel door systems.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... Doors and Frames; (viii) ISDSI-107-80—Thermal Performance Standard for Insulated Steel Door Systems; (ix... certification program for exterior insulated steel door systems. 200.949 Section 200.949 Housing and Urban... program for exterior insulated steel door systems. (a) Applicable standards. (1) All Exterior Insulated...

  6. Human tRNA genes function as chromatin insulators

    PubMed Central

    Raab, Jesse R; Chiu, Jonathan; Zhu, Jingchun; Katzman, Sol; Kurukuti, Sreenivasulu; Wade, Paul A; Haussler, David; Kamakaka, Rohinton T

    2012-01-01

    Insulators help separate active chromatin domains from silenced ones. In yeast, gene promoters act as insulators to block the spread of Sir and HP1 mediated silencing while in metazoans most insulators are multipartite autonomous entities. tDNAs are repetitive sequences dispersed throughout the human genome and we now show that some of these tDNAs can function as insulators in human cells. Using computational methods, we identified putative human tDNA insulators. Using silencer blocking, transgene protection and repressor blocking assays we show that some of these tDNA-containing fragments can function as barrier insulators in human cells. We find that these elements also have the ability to block enhancers from activating RNA pol II transcribed promoters. Characterization of a putative tDNA insulator in human cells reveals that the site possesses chromatin signatures similar to those observed at other better-characterized eukaryotic insulators. Enhanced 4C analysis demonstrates that the tDNA insulator makes long-range chromatin contacts with other tDNAs and ETC sites but not with intervening or flanking RNA pol II transcribed genes. PMID:22085927

  7. Nature and function of insulator protein binding sites in the Drosophila genome

    PubMed Central

    Schwartz, Yuri B.; Linder-Basso, Daniela; Kharchenko, Peter V.; Tolstorukov, Michael Y.; Kim, Maria; Li, Hua-Bing; Gorchakov, Andrey A.; Minoda, Aki; Shanower, Gregory; Alekseyenko, Artyom A.; Riddle, Nicole C.; Jung, Youngsook L.; Gu, Tingting; Plachetka, Annette; Elgin, Sarah C.R.; Kuroda, Mitzi I.; Park, Peter J.; Savitsky, Mikhail; Karpen, Gary H.; Pirrotta, Vincenzo

    2012-01-01

    Chromatin insulator elements and associated proteins have been proposed to partition eukaryotic genomes into sets of independently regulated domains. Here we test this hypothesis by quantitative genome-wide analysis of insulator protein binding to Drosophila chromatin. We find distinct combinatorial binding of insulator proteins to different classes of sites and uncover a novel type of insulator element that binds CP190 but not any other known insulator proteins. Functional characterization of different classes of binding sites indicates that only a small fraction act as robust insulators in standard enhancer-blocking assays. We show that insulators restrict the spreading of the H3K27me3 mark but only at a small number of Polycomb target regions and only to prevent repressive histone methylation within adjacent genes that are already transcriptionally inactive. RNAi knockdown of insulator proteins in cultured cells does not lead to major alterations in genome expression. Taken together, these observations argue against the concept of a genome partitioned by specialized boundary elements and suggest that insulators are reserved for specific regulation of selected genes. PMID:22767387

  8. Wettability of naturally aged silicone and EPDM composite insulators

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gubanski, S.M.; Vlastos, A.E.

    1990-07-01

    This paper reports the wettability of aged surfaces and of the bulk of naturally aged silicone and EPDM insulator housings and of silicone elastomer insulator coatings studied. The samples were taken either directly from the insulators or treated by exposing them to corona discharges and/or to saline pollution. The results show that the contact angles of the silicone rubber insulator surfaces are larger than the contact angles of the RTV silicone rubber coating and of the EPDM rubber insulator surfaces, especially when the surfaces are aged. When the insulators were exposed to corona discharges, the contact angles of the siliconemore » rubber insulators are reduced but after the exposure they recover with time. The contact angles of the EPDM rubber insulators, however, after the exposure, continue to reduce. When exposed to artificial saline pollution, the silicone rubber insulators show a limited recovery of their contact angles with time, while, when exposed to corona discharge, they show a recovery of the contact angle after the exposure. The time for recovery is dependent on the exposure time to the corona discharges.« less

  9. Natural ageing of EPDM composite insulators

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vlastos, A.E.; Sherif, E.

    1990-01-01

    Long-rod composite insulators, with weather sheds (sheds) made of ethylene propylene rubbers (EPDM), were exposed for many years to HVAC and HVDC under realistic conditions and natural pollution. The change of their properties with time and their aging was studied. The results show that the insulator shed material undergoes a slow degradation process and loses successively its water repelling properties which initially make the EPDM composite insulators superior to inorganic glass and porcelain insulator. The outdoor degradation of the shed material depends on the electric stress, in the environmental factors (such as pollution, rain, salt-laden fog, and UV-radiation from sun)more » and on the materials and fillers used in the construction of the composite insulators. A thorough macro- and microscopic study of the EPDM composite insulator sheds illustrates the differences of the surface state of EPDM insulators of different makes in which different basic material compositions and fillers are used. The poor performance of aged EPDM composite insulators compared to inorganic insulators depends on the design and on environmental factors.« less

  10. Passive-dynamic ankle-foot orthosis replicates soleus but not gastrocnemius muscle function during stance in gait: Insights for orthosis prescription.

    PubMed

    Arch, Elisa S; Stanhope, Steven J; Higginson, Jill S

    2016-10-01

    Passive-dynamic ankle-foot orthosis characteristics, including bending stiffness, should be customized for individuals. However, while conventions for customizing passive-dynamic ankle-foot orthosis characteristics are often described and implemented in clinical practice, there is little evidence to explain their biomechanical rationale. To develop and combine a model of a customized passive-dynamic ankle-foot orthosis with a healthy musculoskeletal model and use simulation tools to explore the influence of passive-dynamic ankle-foot orthosis bending stiffness on plantar flexor function during gait. Dual case study. The customized passive-dynamic ankle-foot orthosis characteristics were integrated into a healthy musculoskeletal model available in OpenSim. Quasi-static forward dynamic simulations tracked experimental gait data under several passive-dynamic ankle-foot orthosis conditions. Predicted muscle activations were calculated through a computed muscle control optimization scheme. Simulations predicted that the passive-dynamic ankle-foot orthoses substituted for soleus but not gastrocnemius function. Induced acceleration analyses revealed the passive-dynamic ankle-foot orthosis acts like a uniarticular plantar flexor by inducing knee extension accelerations, which are counterproductive to natural knee kinematics in early midstance. These passive-dynamic ankle-foot orthoses can provide plantar flexion moments during mid and late stance to supplement insufficient plantar flexor strength. However, the passive-dynamic ankle-foot orthoses negatively influenced knee kinematics in early midstance. Identifying the role of passive-dynamic ankle-foot orthosis stiffness during gait provides biomechanical rationale for how to customize passive-dynamic ankle-foot orthoses for patients. Furthermore, these findings can be used in the future as the basis for developing objective prescription models to help drive the customization of passive-dynamic ankle-foot orthosis characteristics. © The International Society for Prosthetics and Orthotics 2015.

  11. Implementation of a quality improvement initiative in Belgian diabetic foot clinics: feasibility and initial results.

    PubMed

    Doggen, Kris; Van Acker, Kristien; Beele, Hilde; Dumont, Isabelle; Félix, Patricia; Lauwers, Patrick; Lavens, Astrid; Matricali, Giovanni A; Randon, Caren; Weber, Eric; Van Casteren, Viviane; Nobels, Frank

    2014-07-01

    This article aims to describe the implementation and initial results of an audit-feedback quality improvement initiative in Belgian diabetic foot clinics. Using self-developed software and questionnaires, diabetic foot clinics collected data in 2005, 2008 and 2011, covering characteristics, history and ulcer severity, management and outcome of the first 52 patients presenting with a Wagner grade ≥ 2 diabetic foot ulcer or acute neuropathic osteoarthropathy that year. Quality improvement was encouraged by meetings and by anonymous benchmarking of diabetic foot clinics. The first audit-feedback cycle was a pilot study. Subsequent audits, with a modified methodology, had increasing rates of participation and data completeness. Over 85% of diabetic foot clinics participated and 3372 unique patients were sampled between 2005 and 2011 (3312 with a diabetic foot ulcer and 111 with acute neuropathic osteoarthropathy). Median age was 70 years, median diabetes duration was 14 years and 64% were men. Of all diabetic foot ulcers, 51% were plantar and 29% were both ischaemic and deeply infected. Ulcer healing rate at 6 months significantly increased from 49% to 54% between 2008 and 2011. Management of diabetic foot ulcers varied between diabetic foot clinics: 88% of plantar mid-foot ulcers were off-loaded (P10-P90: 64-100%), and 42% of ischaemic limbs were revascularized (P10-P90: 22-69%) in 2011. A unique, nationwide quality improvement initiative was established among diabetic foot clinics, covering ulcer healing, lower limb amputation and many other aspects of diabetic foot care. Data completeness increased, thanks in part to questionnaire revision. Benchmarking remains challenging, given the many possible indicators and limited sample size. The optimized questionnaire allows future quality of care monitoring in diabetic foot clinics. Copyright © 2014 John Wiley & Sons, Ltd.

  12. Impact of concurrent foot pain on health and functional status in people with knee osteoarthritis: data from the osteoarthritis initiative.

    PubMed

    Paterson, Kade L; Hinman, Rana S; Hunter, David J; Wrigley, Tim V; Bennell, Kim L

    2015-07-01

    To document the prevalence of foot pain and foot pain laterality in people with knee osteoarthritis (OA) and to examine its impact on health and function. Participants from the Progression subcohort (n = 1,255, ages 45-79 years) of the Osteoarthritis Initiative with symptomatic tibiofemoral knee OA were included. Prevalence of foot pain, defined as pain in the foot/ankle, and foot pain laterality were determined. Health status was evaluated using the Western Ontario and McMaster Universities Osteoarthritis Index, the Short Form-12 Health Survey, and the Center for Epidemiological Studies Depression Scale. Function was assessed using the 20-meter walk test (WT) and a repeated chair stand test. Differences in health and functional measures were compared between groups with and without foot pain using multivariate analysis of covariance. One-fourth (n = 317 [25%]) of people with knee OA experienced concurrent foot pain, with the majority (n = 174 [55%]) reporting pain in both feet. After adjusting for covariates, people with foot pain scored worse on all health measures and on the 20-meter WT, compared to those without (P < 0.05). Differences in health and function were found between the bilateral and ipsilateral foot pain groups compared to those without foot pain (P < 0.05), but no differences were found with the contralateral group. Foot pain is common in people with knee OA, and bilateral and ipsilateral foot pain adversely affect health and function, suggesting laterality is important. Further research is needed to establish the mechanism and interaction of pathology at these sites and to evaluate foot pain treatment in this population. © 2015, American College of Rheumatology.

  13. Concurrent foot pain is common in people with knee osteoarthritis and impacts health and functional status: data from the Osteoarthritis Initiative

    PubMed Central

    Paterson, Kade L; Hinman, Rana S; Hunter, David J; Wrigley, Tim V; Bennell, Kim L

    2015-01-01

    Objective To document the prevalence of foot pain and foot pain laterality in people with knee osteoarthritis (OA), and to examine its impact on health and function. Methods Participants from the Progression subcohort (n=1255, aged 45-79 years) of the Osteoarthritis Initiative with symptomatic tibiofemoral knee OA were included. Prevalence of foot pain, defined as pain in the foot/ankle, and foot pain laterality was determined. Health status was evaluated using the Western Ontario and McMaster Universities Osteoarthritis Index, the Short Form-12 and the Centre for Epidemiological Studies Depression Scale. Function was assessed using the 20-meter walk test (20MWT) and a repeated chair stand test. Differences in health and functional measures were compared between groups with and without foot pain using multivariate analysis of covariance. Results One quarter (n=317, 25%) of people with knee OA experienced concurrent foot pain, with the majority (n=174, 55%) reporting pain in both feet. After adjusting for covariates, people with foot pain scored worse on all health measures and on the 20MWT compared to those without (p<0.05). Differences in health and function were found between the bilateral and ispilateral foot pain groups compared to those without foot pain (p<0.05), however no differences were found with the contralateral group. Conclusion Foot pain is common in people with knee OA, and bilateral and ipsilateral foot pain adversely affects health and function suggesting laterality is important. Further research is needed to establish the mechanism and interaction of pathology at these sites, and to evaluate foot pain treatment in this population. PMID:25581254

  14. Associations of Foot Posture and Function to Lower Extremity Pain: The Framingham Foot Study

    PubMed Central

    Riskowski, JL; Dufour, AB; Hagedorn, TJ; Hillstrom, Howard; Casey, VA; Hannan, MT

    2014-01-01

    Objective Studies have implicated foot posture and foot function as risk factors for lower extremity pain. Empirical population-based evidence for this assertion is lacking; therefore, the purpose of this study was to evaluate cross-sectional associations of foot posture and foot function to lower extremity joint pain in a population-based study of adults. Methods Participants were members of the Framingham Foot Study. lower extremity joint pain was determined by the response to the NHANES-type question, “On most days do you have pain, aching or stiffness in your [hips, knees, ankles, or feet]?” Modified Arch Index (MAI) classified participants as having planus, rectus (referent) or cavus foot posture. Center of Pressure Excursion Index (CPEI) classified participants as having over-pronated, normal (referent) or over-supinated foot function. Crude and adjusted (age, gender, BMI) logistic regression determined associations of foot posture and function to lower extremity pain. Results Participants with planus structure had higher odds of knee (1.57, 95% CI: 1.24– 1.99) or ankle (1.47, 95% CI: 1.05–2.06) pain, whereas those with a cavus foot structure had increased odds of ankle pain only (7.56, 95% CI: 1.99–28.8) and pain at one lower extremity site (1.37, 95% CI: 1.04–1.80). Associations between foot function and lower extremity joint pain were not statistically significant, except for a reduced risk of hip pain in those with an over-supinated foot function (0.69, 95% CI: 0.51–0.93). Conclusions These findings offer a link between foot posture and lower extremity pain, highlighting the need for longitudinal or intervention studies. PMID:24591410

  15. Associations of foot posture and function to lower extremity pain: results from a population-based foot study.

    PubMed

    Riskowski, Jody L; Dufour, Alyssa B; Hagedorn, Thomas J; Hillstrom, Howard J; Casey, Virginia A; Hannan, Marian T

    2013-11-01

    Studies have implicated foot posture and foot function as risk factors for lower extremity pain. Empirical population-based evidence for this assertion is lacking; therefore, the purpose of this study was to evaluate cross-sectional associations of foot posture and foot function to lower extremity joint pain in a population-based study of adults. Participants were members of the Framingham Foot Study. Lower extremity joint pain was determined by the response to the National Health and Nutrition Examination Survey-type question, "On most days do you have pain, aching or stiffness in your (hips, knees, ankles, or feet)?" The Modified Arch Index classified participants as having planus, rectus (referent), or cavus foot posture. The Center of Pressure Excursion Index classified participants as having overpronated, normal (referent), or oversupinated foot function. Crude and adjusted (age, sex, and body mass index) logistic regression determined associations of foot posture and function to lower extremity pain. Participants with planus structure had higher odds of knee (odds ratio [OR] 1.57, 95% confidence interval [95% CI] 1.24-1.99) or ankle (OR 1.47, 95% CI 1.05-2.06) pain, whereas those with a cavus foot structure had increased odds of ankle pain only (OR 7.56, 95% CI 1.99-28.8) and pain at 1 lower extremity site (OR 1.37, 95% CI 1.04-1.80). Associations between foot function and lower extremity joint pain were not statistically significant except for a reduced risk of hip pain in those with an oversupinated foot function (OR 0.69, 95% CI 0.51-0.93). These findings offer a link between foot posture and lower extremity pain, highlighting the need for longitudinal or intervention studies. Copyright © 2013 by the American College of Rheumatology.

  16. Diabetic neuropathy and foot complications.

    PubMed

    Boulton, Andrew J M

    2014-01-01

    Foot ulceration and Charcot neuroarthropathy (CN) are well recognized and documented late sequelae of diabetic peripheral, somatic, and sympathetic autonomic neuropathy. The neuropathic foot, however, does not ulcerate spontaneously: it is a combination of loss of sensation due to neuropathy together with other factors such as foot deformity and external trauma that results in ulceration and indeed CN. The commonest trauma leading to foot ulcers in the neuropathic foot in Western countries is from inappropriate footwear. Much of the management of the insensate foot in diabetes has been learned from leprosy which similarly gives rise to insensitive foot ulceration. No expensive equipment is required to identify the high risk foot and recently developed tests such as the Ipswich Touch Test and the Vibratip have been shown to be useful in identifying the high risk foot. A comprehensive screening program, together with education of high risk patients, should help to reduce the all too high incidence of ulceration in diabetes. More recently another very high risk group has been identified, namely patients on dialysis, who are at extremely high risk of developing foot ulceration; this should be preventable. The most important feature in management of neuropathic foot ulceration is offloading as patients can easily walk on active foot ulcers due to the loss of pain sensation. Infection should be treated aggressively and if there is any evidence of peripheral vascular disease, arteriography and appropriate surgical management is also indicated. CN often presents with a unilateral hot, swollen foot and any patient presenting with these features known to have neuropathy should be treated as a Charcot until this is proven otherwise. Most important in the management of acute CN is offloading, often in a total contact cast.

  17. Walking cadence affects rate of plantar foot temperature change but not final temperature in younger and older adults.

    PubMed

    Reddy, Prabhav Nadipi; Cooper, Glen; Weightman, Andrew; Hodson-Tole, Emma; Reeves, Neil D

    2017-02-01

    This study examined the relationship between (1) foot temperature in healthy individuals and walking cadence, (2) temperature change at different locations of the foot, and (3) temperature change and its relationship with vertical pressures exerted on the foot. Eighteen healthy adult volunteers (10 between 30 and 40 years - Age: 33.4±2.4years; 8 above 40 years - Age: 54.1±7.7years) were recruited. A custom-made insole with temperature sensors was placed directly onto the plantar surface of the foot and held in position using a sock. The foot was placed on a pressure sensor and the whole system placed in a canvas shoe. Participants visited the lab on three separate occasions when foot temperature and pressure data were recorded during walking on a treadmill at one of three cadences (80, 100, 120steps/min). The plantar foot temperature increased during walking in both age groups 30-40 years: 4.62±2.00°C, >40years: 5.49±2.30°C, with the rise inversely proportional to initial foot temperature (30-40 years: R 2 =-0.669, >40years: R 2 =-0.816). Foot temperature changes were not different between the two age groups or the different foot locations and did not depend on vertical pressures. Walking cadence affected the rate of change of plantar foot temperature but not the final measured value and no association between temperature change and vertical pressure was found. These results provide baseline values for comparing foot temperature changes in pathological conditions which could inform understanding of pathophysiology and support development of evidence based healthcare guidelines for managing conditions such as diabetic foot ulceration (DFU). Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.

  18. Trends in lumber processing in the western United States. Part I: board foot Scribner volume per cubic foot of timber

    Treesearch

    Charles E. Keegan; Todd A. Morgan; Keith A. Blatner; Jean M. Daniels

    2010-01-01

    This article describes trends in board foot Scribner volume per cubic foot of timber for logs processed by sawmills in the western United States. Board foot to cubic foot (BF/CF) ratios for the period from 2000 through 2006 ranged from 3.70 in Montana to 5.71 in the Four Corners Region (Arizona, Colorado, New Mexico, and Utah). Sawmills in the Four Corners Region,...

  19. Type 2 diabetes–related foot care knowledge and foot self-care practice interventions in the United States: a systematic review of the literature

    PubMed Central

    Bonner, Timethia; Foster, Margaret; Spears-Lanoix, Erica

    2016-01-01

    Introduction The purpose of this systematic literature review is to review published studies on foot care knowledge and foot care practice interventions as part of diabetic foot care self-management interventions. Methods Medline, CINAHL, CENTRAL, and Cochrane Central Register of Controlled Trials databases were searched. References from the included studies were reviewed to identify any missing studies that could be included. Only foot care knowledge and foot care practice intervention studies that focused on the person living with type 2 diabetes were included in this review. Author, study design, sample, intervention, and results were extracted. Results Thirty studies met the inclusion criteria and were classified according to randomized controlled trial (n=9), survey design (n=13), cohort studies (n=4), cross-sectional studies (n=2), qualitative studies (n=2), and case series (n=1). Improving lower extremity complications associated with type 2 diabetes can be done through effective foot care interventions that include foot care knowledge and foot care practices. Conclusion Preventing these complications, understanding the risk factors, and having the ability to manage complications outside of the clinical encounter is an important part of a diabetes foot self-care management program. Interventions and research studies that aim to reduce lower extremity complications are still lacking. Further research is needed to test foot care interventions across multiple populations and geographic locations. PMID:26899439

  20. Type 2 diabetes-related foot care knowledge and foot self-care practice interventions in the United States: a systematic review of the literature.

    PubMed

    Bonner, Timethia; Foster, Margaret; Spears-Lanoix, Erica

    2016-01-01

    The purpose of this systematic literature review is to review published studies on foot care knowledge and foot care practice interventions as part of diabetic foot care self-management interventions. Medline, CINAHL, CENTRAL, and Cochrane Central Register of Controlled Trials databases were searched. References from the included studies were reviewed to identify any missing studies that could be included. Only foot care knowledge and foot care practice intervention studies that focused on the person living with type 2 diabetes were included in this review. Author, study design, sample, intervention, and results were extracted. Thirty studies met the inclusion criteria and were classified according to randomized controlled trial (n=9), survey design (n=13), cohort studies (n=4), cross-sectional studies (n=2), qualitative studies (n=2), and case series (n=1). Improving lower extremity complications associated with type 2 diabetes can be done through effective foot care interventions that include foot care knowledge and foot care practices. Preventing these complications, understanding the risk factors, and having the ability to manage complications outside of the clinical encounter is an important part of a diabetes foot self-care management program. Interventions and research studies that aim to reduce lower extremity complications are still lacking. Further research is needed to test foot care interventions across multiple populations and geographic locations.

  1. Illness beliefs predict self-care behaviours in patients with diabetic foot ulcers: a prospective study.

    PubMed

    Vedhara, Kavita; Dawe, Karen; Wetherell, Mark A; Miles, Jeremy N V; Cullum, Nicky; Dayan, Colin; Drake, Nicola; Price, Patricia; Tarlton, John; Weinman, John; Day, Andrew; Campbell, Rona

    2014-10-01

    Patients' illness beliefs are known to be influential determinants of self-care behaviours in many chronic conditions. In a prospective observational study we examined their role in predicting foot self-care behaviours in patients with diabetic foot ulcers. Patients (n=169) were recruited from outpatient podiatry clinics. Clinical and demographic factors, illness beliefs and foot self-care behaviours were assessed as baseline (week 0). Foot self-care behaviours were assessed again 6, 12 and 24 weeks later. Linear regressions examined the contribution of beliefs at baseline to subsequent foot self-care behaviours, controlling for past behaviour (i.e., foot self-care at baseline) and clinical and demographic factors that may affect foot self-care (i.e., age and ulcer size). Our models accounted for between 42 and 58% of the variance in foot self-care behaviours. Even after controlling for past foot-care behaviours, age and ulcer size; patients' beliefs regarding the symptoms associated with ulceration, their understanding of ulceration and their perceived personal control over ulceration emerged as independent determinants of foot self-care. Patients' beliefs are important determinants of foot-care practices. They may, therefore, also be influential in determining ulcer outcomes. Interventions aimed at modifying illness beliefs may offer a means for promoting self-care and improving ulcer outcomes. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  2. Potential Biomolecules and Current Treatment Technologies for Diabetic Foot Ulcer: an Overview.

    PubMed

    Khashim, Zenith; Samuel, Shila; Duraisamy, Nallusamy; Krishnan, Kathiravan

    2017-05-18

    Diabetic foot ulceration remains a major challenge and is one of the most expensive and leading causes of major and minor amputations among patients with diabetic foot ulcer. Hence the purpose of this review is to emphasize on potential molecular markers involved in diabetic foot ulcer physiology, the efficacy of different types of dressing materials, adjunct therapy and newer therapeutic approach like nanoparticles for the treatment of diabetic foot ulcer. We conducted a systematic literature review search by using Pubmed and other web searches. The quality evidence of diabetic foot ulcer biomolecules and treatments was collected, summarized and compared with other studies. The present investigation suggested that impaired wound healing in diabetic patients is an influence of several factors. All the advanced therapies and foot ulcer dressing materials are not suitable for all types of diabetic foot ulcers, however more prospective follow ups and in vivo and in vitro studies are needed to draw certain conclusion. Several critical wound biomolecules have been identified and are in need to be investigated in diabetic foot ulcers. The application of biocompatible nanoparticles holds a promising approach for designing dressing materials for the treatment of diabetic foot ulcer. Understanding the cellular and molecular events and identifying the appropriate treatment strategies for different foot ulcer grades will reduce recurrence of foot ulcer and lower limb amputation. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  3. Insulation systems for liquid methane fuel tanks for supersonic cruise aircraft

    NASA Technical Reports Server (NTRS)

    Brady, H. F.; Delduca, D.

    1972-01-01

    Two insulation systems for tanks containing liquid methane in supersonic cruise-type aircraft were designed and tested after an extensive materials investigation. One system is an external insulation and the other is an internal wet-type insulation system. Tank volume was maximized by making the tank shape approach a rectangular parallelopiped. One tank was designed to use the external insulation and the other tank to use the internal insulation. Performance of the external insulation system was evaluated on a full-scale tank under the temperature environment of -320 F to 700 F and ambient pressures of ground-level atmospheric to 1 psia. Problems with installing the internal insulation on the test tank prevented full-scale evaluation of performance; however, small-scale testing verified thermal conductivity, temperature capability, and installed density.

  4. A Comparison of Two Injection Locations in Obese Patients Having Lower Leg/Foot Surgery

    ClinicalTrials.gov

    2015-10-13

    Strain of Muscle and/or Tendon of Lower Leg; Fracture of Lower Leg; Crushing Injury of Lower Leg; Fracture Malunion - Ankle and/ or Foot; Complete Tear, Ankle and/or Foot Ligament; Pathological Fracture - Ankle and/or Foot; Loose Body in Joint of Ankle and/or Foot

  5. From the diabetic foot ulcer and beyond: how do foot infections spread in patients with diabetes?

    PubMed Central

    Aragón-Sánchez, Javier; Lázaro-Martínez, Jose Luis; Pulido-Duque, Juan; Maynar, Manuel

    2012-01-01

    A diabetic foot infection is usually the result of a pre-existing foot ulceration and is the leading cause of lower extremity amputation in patients with diabetes. It is widely accepted that diabetic foot infections may be challenging to treat for several reasons. The devastating effects of hyperglycemia on host defense, ischemia, multi-drug resistant bacteria and spreading of infection through the foot may complicate the course of diabetic foot infections. Understanding the ways in which infections spread through the diabetic foot is a pivotal factor in order to decide the best approach for the patient's treatment. The ways in which infections spread can be explained by the anatomical division of the foot into compartments, the tendons included in the compartments, the initial location of the point of entry of the infection and the type of infection that the patient has. The aim of this paper is to further comment on the existed and proposed anatomical principles of the spread of infection through the foot in patients with diabetes. PMID:23050067

  6. Knowledge and Practices of Diabetes Foot Care and Risk of Developing Foot Ulcers in México May Have Implications for Patients of Méxican Heritage Living in the US.

    PubMed

    Bohorquez Robles, Rosa; Compeán Ortiz, Lidia G; González Quirarte, Nora H; Berry, Diane C; Aguilera Pérez, Paulina; Piñones Martínez, Socorro

    2017-06-01

    Purpose The purpose of the study was to examine the relationship between knowledge and foot care practices among adults with type 2 diabetes. Methods A descriptive correlational study examined 200 patients with type 2 diabetes in México. Data collected included the Knowledge and Practices Self-Care Questionnaire and a Podiatry Examination Questionnaire. Data analysis included Pearson's correlations and chi-square tests. Results More than half of the participants had poor knowledge and poor foot care practices. A significant negative correlation between knowledge and practices of foot care and risk of developing diabetes foot ulcers was found. There was no relationship between sociodemographic variables and the risk of developing diabetes foot ulcers. Conclusions Patients with type 2 diabetes served in an outpatient clinic had poor knowledge and practices of foot care. They demonstrated decreased knowledge and practice of foot care and therefore showed a greater risk of developing diabetes foot, which may predispose patients to early complications.

  7. Biomechanical podiatric evaluation in an Italian cohort of patients with systemic sclerosis: A pilot study.

    PubMed

    Bongi, Susanna Maddali; Ravenni, Giovanni; Ciampi, Benedetta; Del Rosso, Angela; El Aoufy, Khadija

    2016-12-01

    Foot problems are often present in Systemic Sclerosis (SSc) patients, however studies regarding podiatric problems related to SSc are lacking and there are no data evaluating the foot biomechanical changes. The aim of the present pilot study was to evaluate podiatric problems in an Italian cohort of SSc patients by assessing received podiatric services, foot pain and disability and biomechanical foot deformity. 25 consecutive SSc patients were enrolled from the Division of Rheumatology, University of Florence. All SSc patients were assessed by: Standards of Care for People with Foot Musculoskeletal Health problems: Audit Tool, Foot Function Index (FFI), Weight and non-weight bearing foot joint assessment, (Foot Posture Index (FPI) and Gait Cycle), Health Assessment Questionnaire (HAQ) and Medical Outcomes Survey Short Form 36 (SF-36). Audit Tool - Only 7 (28%) out of the 25 patients with SSc had a specific podiatric assessment and treatment: no patient received a foot health assessment within the first 6 months of disease diagnosis and no patient received information about foot involvement. 1 patient (4%) received foot assessment every year; 1 patient (4%) received specific information about the disease and 5 patients (20%) received information about the benefits of using adapted footwear and insoles. FFI - Values of pain, disability and activity limitations, reported in FFI, are 4.7±5.1, 5.1±3.2 and 3.2±3.1 (M±DS), respectively. Non-weight bearing foot joint assessment shows a rearfoot varus deformity in 64% of patients, forefoot varus deformity in 42% and 6% forefoot valgus deformity. Weight bearing foot joint assessment, through FPI shows a pronated foot 20% of patients with and 34% with highly pronated overall foot posture. Gait analysis shows that 64% of patients has a contact of the calcaneus in invertion while 36% in eversion. In the midstance, 78% have the foot in pronation and 22% in supination, while in propulsion 12% presents a takeoff of the foot in supination and 88% in the pronation. HAQ result is 1.13±0.80, SFI and SMI scales of SF-36 have scores of 32.38±10.65 and 38.67±11.40, respectively. Our results shows that podiatric problems in SSc patients are common, serious but foot assessment and health care are inadequate. Thus, foot health information should be improved in order to better empower patients to self-manage low risk problems and help identify high-risk problems, which require specialist care.

  8. Research and application of high performance GPES rigid foam composite plastic insulation boards

    NASA Astrophysics Data System (ADS)

    sun, Hongming; xu, Hongsheng; Han, Feifei

    2017-09-01

    A new type of heat insulation board named GPES was prepared by several polymers and modified nano-graphite particles, injecting high-pressure supercritical CO2. Compared with the traditional thermal insulation material, GPES insulation board has higher roundness bubble and thinner bubble wall. Repeatability and reproducibility tests show that melting knot, dimensional stability, strength and other physical properties are significantly better than traditional organic heat insulation materials. Especially the lower and more stable thermal conductivity of GPES can significantly reduce thermal insulation layer thickness. Obviously GPES is the best choice of insulation materials with the implement of 75% and higher energy efficiency standard.

  9. Modeling subsurface stormflow initiation in low-relief landscapes

    NASA Astrophysics Data System (ADS)

    Hopp, Luisa; Vaché, Kellie B.; Rhett Jackson, C.; McDonnell, Jeffrey J.

    2015-04-01

    Shallow lateral subsurface flow as a runoff generating mechanism at the hillslope scale has mostly been studied in steeper terrain with typical hillside angles of 10 - 45 degrees. These studies have shown that subsurface stormflow is often initiated at the interface between a permeable upper soil layer and a lower conductivity impeding layer, e.g. a B horizon or bedrock. Many studies have identified thresholds of event size and soil moisture states that need to be exceeded before subsurface stormflow is initiated. However, subsurface stormflow generation on low-relief hillslopes has been much less studied. Here we present a modeling study that investigates the initiation of subsurface stormflow on low-relief hillslopes in the Upper Coastal Plain of South Carolina, USA. Hillslopes in this region typically have slope angles of 2-5 degrees. Topsoils are sandy, underlain by a low-conductivity sandy clay loam Bt horizon. Subsurface stormflow has only been intercepted occasionally in a 120 m long trench, and often subsurface flow was not well correlated with stream signals, suggesting a disconnect between subsurface flow on the hillslopes and stream flow. We therefore used a hydrologic model to better understand which conditions promote the initiation of subsurface flow in this landscape, addressing following questions: Is there a threshold event size and soil moisture state for producing lateral subsurface flow? What role does the spatial pattern of depth to the impeding clay layer play for subsurface stormflow dynamics? We reproduced a section of a hillslope, for which high-resolution topographic data and depth to clay measurements were available, in the hydrologic model HYDRUS-3D. Soil hydraulic parameters were based on experimentally-derived data. The threshold analysis was first performed using hourly climate data records for 2009-2010 from the study site to drive the simulation. For this period also trench measurements of subsurface flow were available. In addition, we also ran a longer-term simulation, using daily climate data for a nine year period to include more variable climate conditions in the threshold analysis. The model captured the observed subsurface flow instances very well. The threshold analysis indicated that the occurrence of subsurface stormflow uncommon, with a large proportion of the water perching above the clay layer percolating vertically into the clay layer. Event sizes of approximately 70-80 mm were required for initiating subsurface stormflow. The hourly data from 2009-2010 was subsequently used to test if the actual spatial distribution of depth to clay is a major control for the occurrence and magnitude of lateral subsurface flow. Results suggest that in this low-relief landscape also a spatially uniform mean depth to clay reproduces well the hydrologic behavior.

  10. Problem Definition Study of Requirements for Vapor Retarders in the Building Envelope.

    DTIC Science & Technology

    1982-11-01

    be used, and that cellular glass should be used rather than fibrous glass, mineral wool , and organic fiber insulation materials. -48- 6 Comment: (This...Oregon area. 71 were insulated with UF-foam, cellulose, and mineral wool ; 25 were uninsulated. q b. All insulated homes had been retrofitted for 3 to...ACHR was 18.7, for mineral wool insulated homes 16.4, for cellulose insulated homes 13.6, and for UF-foam insulated homes 15.2. f. No tracer-gas air

  11. Thick film magnetic nanoparticulate composites and method of manufacture thereof

    NASA Technical Reports Server (NTRS)

    Ge, Shihui (Inventor); Yan, Dajing (Inventor); Xiao, Danny T. (Inventor); Ma, Xinqing (Inventor); Zhang, Yide (Inventor); Zhang, Zongtao (Inventor)

    2009-01-01

    Thick film magnetic/insulating nanocomposite materials, with significantly reduced core loss, and their manufacture are described. The insulator coated magnetic nanocomposite comprises one or more magnetic components, and an insulating component. The magnetic component comprises nanometer scale particles (about 1 to about 100 nanometers) coated by a thin-layered insulating phase. While the intergrain interaction between the immediate neighboring magnetic nanoparticles separated by the insulating phase provides the desired soft magnetic properties, the insulating material provides high resistivity, which reduces eddy current loss.

  12. Removal of Pre-Formed Asbestos Insulation. A Project of the Manufacturing Technology Program.

    DTIC Science & Technology

    1982-10-01

    of Generator No. 5 4-18 21 Insulation on Exhaust Stack of Generator No. 6 4-19 22 Insulation on Overhead Pipe 4-19 23 Glasswool Insulation Construction...material insulation was glasswool . Since the glasswool does not have the capacity to absorb as much solution as asbestos insulation, the excess amount... glasswool (which was not suspected). Ran- dom core sampling undertaken earlier in the year had not revealed the presence of any glasswool . Pre-test core

  13. Immediate-term effects of use of an ankle-foot orthosis with an oil damper on the gait of stroke patients when walking without the device.

    PubMed

    Yamamoto, Sumiko; Ibayashi, Setsuro; Fuchi, Masako; Yasui, Tadashi

    2015-04-01

    An ankle-foot orthosis using an oil damper is designed to enable natural movement of the ankle joint. Wearing an ankle-foot orthosis using an oil damper has been demonstrated to assist the first rocker in stroke patients, but its effect on their gait when not wearing it is unclear. To determine the effect of use of ankle-foot orthosis using an oil damper on the gait of stroke patients with hemiparesis when not wearing the ankle-foot orthosis. Crossover study. The gait of eight stroke patients in the chronic phase when not wearing an ankle-foot orthosis was measured, using a three-dimensional motion analysis system, before using the ankle-foot orthosis using an oil damper and then without and with using the ankle-foot orthosis using an oil damper after 3 weeks of use. Differences in gait were compared between the three measurement conditions. Use of ankle-foot orthosis using an oil damper significantly decreased preswing time and significantly increased the positive ankle joint power in stance when not wearing the ankle-foot orthosis using an oil damper. These changes indicate the promising therapeutic effects of ankle-foot orthosis using an oil damper use and suggest the ankle-foot orthosis using an oil damper's potential as a therapeutic device. After 3 weeks of use of an ankle-foot orthosis using an oil damper, which assists the first rocker, the gait of stroke patients in the chronic phase when not wearing the ankle-foot orthosis using an oil damper was improved. Preswing time was significantly decreased and positive ankle joint power was significantly increased. The ankle-foot orthosis using an oil damper, which assists the first rocker function with natural movement of the ankle joint during gait, has the potential to improve the gait of stroke patients after immediate-term use. © The International Society for Prosthetics and Orthotics 2014.

  14. Analysis of joint force and torque for the human and non-human ape foot during bipedal walking with implications for the evolution of the foot.

    PubMed

    Wang, Weijie; Abboud, Rami J; Günther, Michael M; Crompton, Robin H

    2014-08-01

    The feet of apes have a different morphology from those of humans. Until now, it has merely been assumed that the morphology seen in humans must be adaptive for habitual bipedal walking, as the habitual use of bipedal walking is generally regarded as one of the most clear-cut differences between humans and apes. This study asks simply whether human skeletal proportions do actually enhance foot performance during human-like bipedalism, by examining the influence of foot proportions on force, torque and work in the foot joints during simulated bipedal walking. Skeletons of the common chimpanzee, orangutan, gorilla and human were represented by multi-rigid-body models, where the components of the foot make external contact via finite element surfaces. The models were driven by identical joint motion functions collected from experiments on human walking. Simulated contact forces between the ground and the foot were found to be reasonably comparable with measurements made during human walking using pressure- and force-platforms. Joint force, torque and work in the foot were then predicted. Within the limitations of our model, the results show that during simulated human-like bipedal walking, (1) the human and non-human ape (NHA) feet carry similar joint forces, although the distributions of the forces differ; (2) the NHA foot incurs larger joint torques than does the human foot, although the human foot has higher values in the first tarso-metatarsal and metatarso-phalangeal joints, whereas the NHA foot incurs higher values in the lateral digits; and (3) total work in the metatarso-phalangeal joints is lower in the human foot than in the NHA foot. The results indicate that human foot proportions are indeed well suited to performance in normal human walking. © 2014 Anatomical Society.

  15. Analysis of joint force and torque for the human and non-human ape foot during bipedal walking with implications for the evolution of the foot

    PubMed Central

    Wang, Weijie; Abboud, Rami J; Günther, Michael M; Crompton, Robin H

    2014-01-01

    The feet of apes have a different morphology from those of humans. Until now, it has merely been assumed that the morphology seen in humans must be adaptive for habitual bipedal walking, as the habitual use of bipedal walking is generally regarded as one of the most clear-cut differences between humans and apes. This study asks simply whether human skeletal proportions do actually enhance foot performance during human-like bipedalism, by examining the influence of foot proportions on force, torque and work in the foot joints during simulated bipedal walking. Skeletons of the common chimpanzee, orangutan, gorilla and human were represented by multi-rigid-body models, where the components of the foot make external contact via finite element surfaces. The models were driven by identical joint motion functions collected from experiments on human walking. Simulated contact forces between the ground and the foot were found to be reasonably comparable with measurements made during human walking using pressure- and force-platforms. Joint force, torque and work in the foot were then predicted. Within the limitations of our model, the results show that during simulated human-like bipedal walking, (1) the human and non-human ape (NHA) feet carry similar joint forces, although the distributions of the forces differ; (2) the NHA foot incurs larger joint torques than does the human foot, although the human foot has higher values in the first tarso-metatarsal and metatarso-phalangeal joints, whereas the NHA foot incurs higher values in the lateral digits; and (3) total work in the metatarso-phalangeal joints is lower in the human foot than in the NHA foot. The results indicate that human foot proportions are indeed well suited to performance in normal human walking. PMID:24925580

  16. Crystal structure of laser-induced subsurface modifications in Si

    NASA Astrophysics Data System (ADS)

    Verburg, P. C.; Smillie, L. A.; Römer, G. R. B. E.; Haberl, B.; Bradby, J. E.; Williams, J. S.; Huis in't Veld, A. J.

    2015-08-01

    Laser-induced subsurface modification of dielectric materials is a well-known technology. Applications include the production of optical components and selective etching. In addition to dielectric materials, the subsurface modification technology can be applied to silicon, by employing near to mid-infrared radiation. An application of subsurface modifications in silicon is laser-induced subsurface separation, which is a method to separate wafers into individual dies. Other applications for which proofs of concept exist are the formation of waveguides and resistivity tuning. However, limited knowledge is available about the crystal structure of subsurface modifications in silicon. In this work, we investigate the geometry and crystal structure of laser-induced subsurface modifications in monocrystalline silicon wafers. In addition to the generation of lattice defects, we found that transformations to amorphous silicon and Si -iii/Si -xii occur as a result of the laser irradiation.

  17. Investigation of potential waste material insulating properties at different temperature for thermal storage application

    NASA Astrophysics Data System (ADS)

    Ali, T. Z. S.; Rosli, A. B.; Gan, L. M.; Billy, A. S.; Farid, Z.

    2013-12-01

    Thermal energy storage system (TES) is developed to extend the operation of power generation. TES system is a key component in a solar energy power generation plant, but the main issue in designing the TES system is its thermal capacity of storage materials, e.g. insulator. This study is focusing on the potential waste material acts as an insulator for thermal energy storage applications. As the insulator is used to absorb heat, it is needed to find suitable material for energy conversion and at the same time reduce the waste generation. Thus, a small-scale experimental testing of natural cooling process of an insulated tank within a confined room is conducted. The experiment is repeated by changing the insulator from the potential waste material and also by changing the heat transfer fluid (HTF). The analysis presented the relationship between heat loss and the reserved period by the insulator. The results show the percentage of period of the insulated tank withstands compared to tank insulated by foam, e.g. newspaper reserved the period of 84.6% as much as foam insulated tank to withstand the heat transfer of cooking oil to the surrounding. The paper finally justifies the most potential waste material as an insulator for different temperature range of heat transfer fluid.

  18. Relating sub-surface ice features to physiological stress in a climate sensitive mammal, the American pika (Ochotona princeps).

    PubMed

    Wilkening, Jennifer L; Ray, Chris; Varner, Johanna

    2015-01-01

    The American pika (Ochotona princeps) is considered a sentinel species for detecting ecological effects of climate change. Pikas are declining within a large portion of their range, and ongoing research suggests loss of sub-surface ice as a mechanism. However, no studies have demonstrated physiological responses of pikas to sub-surface ice features. Here we present the first analysis of physiological stress in pikas living in and adjacent to habitats underlain by ice. Fresh fecal samples were collected non-invasively from two adjacent sites in the Rocky Mountains (one with sub-surface ice and one without) and analyzed for glucocorticoid metabolites (GCM). We also measured sub-surface microclimates in each habitat. Results indicate lower GCM concentration in sites with sub-surface ice, suggesting that pikas are less stressed in favorable microclimates resulting from sub-surface ice features. GCM response was well predicted by habitat characteristics associated with sub-surface ice features, such as lower mean summer temperatures. These results suggest that pikas inhabiting areas without sub-surface ice features are experiencing higher levels of physiological stress and may be more susceptible to changing climates. Although post-deposition environmental effects can confound analyses based on fecal GCM, we found no evidence for such effects in this study. Sub-surface ice features are key to water cycling and storage and will likely represent an increasingly important component of water resources in a warming climate. Fecal samples collected from additional watersheds as part of current pika monitoring programs could be used to further characterize relationships between pika stress and sub-surface ice features.

  19. Optimal foot shape for a passive dynamic biped.

    PubMed

    Kwan, Maxine; Hubbard, Mont

    2007-09-21

    Passive walking dynamics describe the motion of a biped that is able to "walk" down a shallow slope without any actuation or control. Instead, the walker relies on gravitational and inertial effects to propel itself forward, exhibiting a gait quite similar to that of humans. These purely passive models depend on potential energy to overcome the energy lost when the foot impacts the ground. Previous research has demonstrated that energy loss at heel-strike can vary widely for a given speed, depending on the nature of the collision. The point of foot contact with the ground (relative to the hip) can have a significant effect: semi-circular (round) feet soften the impact, resulting in much smaller losses than point-foot walkers. Collisional losses are also lower if a single impulse is broken up into a series of smaller impulses that gradually redirect the velocity of the center of mass rather than a single abrupt impulse. Using this principle, a model was created where foot-strike occurs over two impulses, "heel-strike" and "toe-strike," representative of the initial impact of the heel and the following impact as the ball of the foot strikes the ground. Having two collisions with the flat-foot model did improve efficiency over the point-foot model. Representation of the flat-foot walker as a rimless wheel helped to explain the optimal flat-foot shape, driven by symmetry of the virtual spoke angles. The optimal long period foot shape of the simple passive walking model was not very representative of the human foot shape, although a reasonably anthropometric foot shape was predicted by the short period solution.

  20. Foot Type Biomechanics Part 2: are structure and anthropometrics related to function?

    PubMed

    Mootanah, Rajshree; Song, Jinsup; Lenhoff, Mark W; Hafer, Jocelyn F; Backus, Sherry I; Gagnon, David; Deland, Jonathan T; Hillstrom, Howard J

    2013-03-01

    Many foot pathologies are associated with specific foot types. If foot structure and function are related, measurement of either could assist with differential diagnosis of pedal pathologies. Biomechanical measures of foot structure and function are related in asymptomatic healthy individuals. Sixty-one healthy subjects' left feet were stratified into cavus (n=12), rectus (n=27) and planus (n=22) foot types. Foot structure was assessed by malleolar valgus index, arch height index, and arch height flexibility. Anthropometrics (height and weight), age, and walking speed were measured. Foot function was assessed by center of pressure excursion index, peak plantar pressure, maximum force, and gait pattern parameters. Foot structure and anthropometric variables were entered into stepwise linear regression models to identify predictors of function. Measures of foot structure and anthropometrics explained 10-37% of the model variance (adjusted R(2)) for gait pattern parameters. When walking speed was included, the adjusted R(2) increased to 45-77% but foot structure was no longer a factor. Foot structure and anthropometrics predicted 7-47% of the model variance for plantar pressure and 16-64% for maximum force parameters. All multivariate models were significant (p<0.05), supporting acceptance of the hypothesis. Foot structure and function are related in asymptomatic healthy individuals. The structural parameters employed are basic measurements that do not require ionizing radiation and could be used in a clinical setting. Further research is needed to identify additional predictive parameters (plantar soft tissue characteristics, skeletal alignment, and neuromuscular control) and to include individuals with pathology. Copyright © 2012. Published by Elsevier B.V.

  1. Foot Type Biomechanics Part 2: Are structure and anthropometrics related to function?

    PubMed Central

    Mootanah, Rajshree; Song, Jinsup; Lenhoff, Mark W.; Hafer, Jocelyn F.; Backus, Sherry I.; Gagnon, David; Deland, Jonathan T.; Hillstrom, Howard J.

    2013-01-01

    Background Many foot pathologies are associated with specific foot types. If foot structure and function are related, measurement of either could assist with differential diagnosis of pedal pathologies. Hypothesis Biomechanical measures of foot structure and function are related in asymptomatic healthy individuals. Methods Sixty-one healthy subjects' left feet were stratified into cavus (n = 12), rectus (n = 27) and planus (n = 22) foot types. Foot structure was assessed by malleolar valgus index, arch height index, and arch height flexibility. Anthropometrics (height and weight), age, and walking speed were measured. Foot function was assessed by center of pressure excursion index, peak plantar pressure, maximum force, and gait pattern parameters. Foot structure and anthropometric variables were entered into stepwise linear regression models to identify predictors of function. Results Measures of foot structure and anthropometrics explained 10–37% of the model variance (adjusted R2) for gait pattern parameters. When walking speed was included, the adjusted R2 increased to 45–77% but foot structure was no longer a factor. Foot structure and anthropometrics predicted 7–47% of the model variance for plantar pressure and 16–64% for maximum force parameters. All multivariate models were significant (p < 0.05), supporting acceptance of the hypothesis. Discussion and conclusion Foot structure and function are related in asymptomatic healthy individuals. The structural parameters employed are basic measurements that do not require ionizing radiation and could be used in a clinical setting. Further research is needed to identify additional predictive parameters (plantar soft tissue characteristics, skeletal alignment, and neuromuscular control) and to include individuals with pathology. PMID:23107624

  2. One- and multi-segment foot models lead to opposite results on ankle joint kinematics during gait: Implications for clinical assessment.

    PubMed

    Pothrat, Claude; Authier, Guillaume; Viehweger, Elke; Berton, Eric; Rao, Guillaume

    2015-06-01

    Biomechanical models representing the foot as a single rigid segment are commonly used in clinical or sport evaluations. However, neglecting internal foot movements could lead to significant inaccuracies on ankle joint kinematics. The present study proposed an assessment of 3D ankle kinematic outputs using two distinct biomechanical models and their application in the clinical flat foot case. Results of the Plug in Gait (one segment foot model) and the Oxford Foot Model (multisegment foot model) were compared for normal children (9 participants) and flat feet children (9 participants). Repeated measures of Analysis of Variance have been performed to assess the Foot model and Group effects on ankle joint kinematics. Significant differences were observed between the two models for each group all along the gait cycle. In particular for the flat feet group, opposite results between the Oxford Foot Model and the Plug in Gait were revealed at heelstrike, with the Plug in Gait showing a 4.7° ankle dorsal flexion and 2.7° varus where the Oxford Foot Model showed a 4.8° ankle plantar flexion and 1.6° valgus. Ankle joint kinematics of the flat feet group was more affected by foot modeling than normal group. Foot modeling appeared to have a strong influence on resulting ankle kinematics. Moreover, our findings showed that this influence could vary depending on the population. Studies involving ankle joint kinematic assessment should take foot modeling with caution. Copyright © 2015 Elsevier Ltd. All rights reserved.

  3. Excess Cost and Healthcare Resources Associated With Delayed Diagnosis of Charcot Foot.

    PubMed

    Labovitz, Jonathan M; Shapiro, Jarrod M; Satterfield, V Kathleen; Smith, Nathanael T

    2018-06-21

    The purpose of the present study was to demonstrate the effect of a delayed diagnosis of Charcot foot on acute care cost and usage. We used International Classification of Disease, Ninth Revision, Clinical Modification codes, and the California Office for Statewide Health Planning and Development 2009 to 2012 public patient discharge files to identify patients with type 2 diabetes mellitus and Charcot foot. The costs and length of stay were compared for those with a diagnosis of Charcot foot on admission compared with those who received a delayed diagnosis of Charcot foot before discharge. Patient demographic data, diagnoses often mistaken for Charcot foot, and procedures often performed for Charcot foot were assessed to determine the potential effect on costs and length of stay in Charcot foot subjects. A delayed Charcot foot diagnosis was associated with 10.8% greater inpatient costs and 12.1% longer length of stay. These patients required greater resource usage owing to the significantly greater number of procedures performed. A significantly greater number of patients underwent lower extremity amputation when the diagnosis was delayed, resulting in a 30.4% increase in costs and 31.6% longer length of stay. A greater rate of diabetic foot ulcers, foot infections, and osteomyelitis was also observed; however, the cost was only affected by osteomyelitis, and the length of stay was not significantly affected. A delayed diagnosis of Charcot foot at admission resulted in significantly increased acute care costs and longer lengths of stay. Copyright © 2018 The American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  4. Calcium silicate insulation structure

    DOEpatents

    Kollie, Thomas G.; Lauf, Robert J.

    1995-01-01

    An insulative structure including a powder-filled evacuated casing utilizes a quantity of finely divided synthetic calcium silicate having a relatively high surface area. The resultant structure-provides superior thermal insulating characteristics over a broad temperature range and is particularly well-suited as a panel for a refrigerator or freezer or the insulative barrier for a cooler or a insulated bottle.

  5. Orbital disc insulator for SF.sub.6 gas-insulated bus

    DOEpatents

    Bacvarov, Dosio C.; Gomarac, Nicholas G.

    1977-01-01

    An insulator for supporting a high voltage conductor within a gas-filled grounded housing consists of radially spaced insulation rings fitted to the exterior of the bus and the interior of the grounded housing respectively, and the spaced rings are connected by trefoil type rings which are integrally formed with the spaced insulation rings.

  6. Foundation Report, Dam & Spillway, Taylorsville Lake, Ohio River Basin, Salt River, Kentucky.

    DTIC Science & Technology

    1983-04-01

    methods. The spacing of the primary holes was set on 10- foot centers, followed by secondary holes on 5- foot centers and tertiary holes on 2.5- foot ...88’ and 5+00. This area was further divided into 100- foot sections and drilled and grouted in alternating sections. Sections 7, 9 and 5 were drilled...100- foot sections and grouted by alternate sections to preclude violating the 100- foot spacing requirement. Many of the first holes on the left abutment

  7. Biomechanics of the Ankle-Foot System during Stair Ambulation: Implications for Design of Advanced Ankle-Foot Prostheses

    DTIC Science & Technology

    2011-12-15

    Biomechanics of the ankle–foot system during stair ambulation: Implications for design of advanced ankle–foot prostheses$ Emily H. Sinitski a, Andrew...Wilken). Please cite this article as: Sinitski, E.H., et al., Biomechanics of the ankle–foot system during stair ambulation: Implications for design of...REPORT TYPE 3. DATES COVERED 00-00-2011 to 00-00-2011 4. TITLE AND SUBTITLE Biomechanics Of The Ankle-Foot System During Stair Ambulation

  8. Experimental Study of Magnetic Field Production and Dielectric Breakdown of Auto-Magnetizing Liners

    NASA Astrophysics Data System (ADS)

    Shipley, Gabriel; Awe, Thomas; Hutchinson, Trevor; Hutsel, Brian; Slutz, Stephen; Lamppa, Derek

    2017-10-01

    AutoMag liners premagnetize the fuel in MagLIF targets and provide enhanced x-ray diagnostic access and increased current delivery without requiring external field coils. AutoMag liners are composite liners made with discrete metallic helical conduction paths separated by insulating material. First, a low dI/dt ``foot'' current pulse (1 MA in 100 ns) premagnetizes the fuel. Next, a higher dI/dt pulse with larger induced electric field initiates breakdown on the composite liner's; surface, switching the current from helical to axial to implode the liner. Experiments on MYKONOS have tested the premagnetization and breakdown phases of AutoMag and demonstrate axial magnetic fields above 90 Tesla for a 550 kA peak current pulse. Electric fields of 17 MV/m have been generated before breakdown. AutoMag may enhance MagLIF performance by increasing the premagnetization strength significantly above 30 T, thus reducing thermal-conduction losses and mitigating anomalous diffusion of magnetic field out of hotter fuel regions, by, for example, the Nernst thermoelectric effect. This project was funded in part by Sandia's Laboratory Directed Research and Development Program (Projects No. 200169 and 195306).

  9. Plantar Pressure Distribution among Older Persons with Different Types of Foot and Its Correlation with Functional Reach Distance

    PubMed Central

    2016-01-01

    Background. Changes in biomechanical structures of human foot are common in the older person, which may lead to alteration of foot type and plantar pressure distribution. We aimed to examine how foot type affects the plantar pressure distribution and to determine the relationship between plantar pressure distribution and functional reach distance in older persons. Methods. Fifty community-dwelling older persons (age: 69.98 ± 5.84) were categorized into three groups based on the Foot Posture Index. The plantar pressure (max⁡P) and contact area were analyzed using Footscan® RSScan platform. The Kruskal-Wallis test was used to compare the plantar pressure between foot types and Spearman's correlation coefficient was used to correlate plantar pressure with the functional reach distance. Results. There were significant differences of max⁡P in the forefoot area across all foot types. The post hoc analysis found significantly lower max⁡P in the pronated foot compared to the supinated foot. A high linear rank correlation was found between functional reach distance and max⁡P of the rearfoot region of the supinated foot. Conclusions. These findings suggested that types of the foot affect the plantar maximal pressure in older persons with functional reach distance showing some associations. PMID:27980874

  10. Muscular activity and torque of the foot dorsiflexor muscles during decremental isometric test: A cross-sectional study.

    PubMed

    Ruiz-Muñoz, Maria; González-Sánchez, Manuel; Martín-Martín, Jaime; Cuesta-Vargas, Antonio I

    2017-06-01

    To analyse the torque variation level that could be explained by the muscle activation (EMG) amplitude of the three major foot dorsiflexor muscles (tibialis anterior (TA), extensor digitorum longus (EDL), extensor hallucis longus (EHL)) during isometric foot dorsiflexion at different intensities. In a cross-sectional study, forty-one subjects performed foot dorsiflexion at 100%, 75%, 50% and 25% of maximal voluntary contractions (MVC) with the hip and knee flexed 90° and the ankle in neutral position (90° between leg and foot). Three foot dorsiflexions were performed for each intensity. Outcome variables were: maximum (100% MVC) and relative torque (75%, 50%, 25% MVC), maximum and relative EMG amplitude. A linear regression analysis was calculated for each intensity of the isometric foot dorsiflexion. The degree of torque variation (dependent variable) from the independent variables explain (EMG amplitude of the three major foot dorsiflexor muscles) the increases when the foot dorsiflexion intensity is increased, with values of R 2 that range from 0.194 (during 25% MVC) to 0.753 (during 100% MVC). The reliability of the outcome variables was excellent. The EMG amplitude of the three main foot dorsiflexors exhibited more variance in the dependent variable (torque) when foot dorsiflexion intensity increases. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. The prevalence of diabetic foot disease in the Waikato region.

    PubMed

    O'Shea, C; McClintock, J; Lawrenson, R

    2017-07-01

    The aim of this study was to establish the prevalence of diabetic foot disease by utilising the retinal eye screening register in the Waikato region of New Zealand. Understanding both the prevalence and the degree of foot disease across the general diabetes population will help to determine what podiatry services are required for people with diabetes. 2192 people aged 15years and over, who attended the Waikato Regional Diabetes Service mobile retinal photo screening service for the six-month period between May and November 2014, consented to a foot screen including testing for sensation and pedal pulses. A digital image was taken of the dorsal and plantar aspect of each foot for review by a registered Podiatrist. Thirteen percent of the study sample was identified as having a high-risk foot including active foot complications. 65% were categorised as low risk and a further 22% at moderate risk of diabetic foot disease. Factors identified as significant included age, type of diabetes, duration of diabetes, and smoking. These factors placed people at greater risk of diabetic foot disease. A significant number of people with diabetes are at risk of diabetic foot disease. This study has highlighted the need for targeted podiatry services to address diabetic foot disease. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. SKITTER foot design

    NASA Technical Reports Server (NTRS)

    Choi, Gene; Jones, David L.; Morris, James; Parham, Martin; Stephens, Jim; Yancey, Gregg

    1987-01-01

    A mechanical design team was formed to design a foot for the lunar utility vehicle SKITTER. The primary design was constrained to be a ski pole design compatible with the existing femur-tibia design legs. The lunar environment had several important effects on the foot design. Three materials were investigated for the SKITTER foot: aluminum alloys, cold worked stainless steel alloys, and titanium alloys. Thin film coatings were investigated as a method of wear reduction for the foot. The performance of the foot is dependent on the action of the legs. The range of motion for the legs was determined to be vertical to 15 degrees above horizontal. An impact analysis was performed for the foot movement, but the results were determined to be inconclusive due to unknown soil parameters. The initial foot design configuration consisted of an annulus attached to the pointed pole. The annulus was designed to prevent excess sinkage. Later designs call for a conical shaped foot with a disk at the point of the tibia attachment. The conical design was analyzed for strength and deflection by two different approaches. A deformable body analysis was performed for the foot under crane load in crane position, and also under actuator load in the vertical position. In both cases, the deflection of the foot was insignificant and the stresses well below the strength of the titanium alloy.

  13. Combined Ankle-Foot Energetics are Conserved When Distal Foot Energy Absorption is Minimized.

    PubMed

    Arch, Elisa S; Fylstra, Bretta L

    2016-12-01

    The large, late-stance energy generated by the ankle is believed to be critical during gait. However, the distal foot absorbs/dissipates a considerable amount of energy during the same phase. Thus, the energy generated by the combined ankle-foot system is more modest, which raises questions regarding the necessity of such a large ankle power and the interplay between foot and ankle energetics. This study aimed to evaluate our conservation of energy hypothesis, which predicted if distal foot energy absorption/dissipation was reduced, then less energy would be generated at the ankle and thus the same combined ankle-foot energetics would be achieved. Motion analysis data were collected as healthy subjects walked under 2 conditions (Shoes, Footplate). In the Footplate condition, the shoe was replaced with a customized, rigid footplate with a rocker profile. In support of the hypothesis, there was significantly less positive ankle and less negative distal foot work with footplate use, resulting in very similar combined ankle-foot work between conditions. These findings suggest that there is an interplay between the energy generated by the ankle and absorbed by the foot. This interplay should be considered when designing orthotic and prosthetic ankle-foot systems and rehabilitation programs for individuals with weakened ankle muscles.

  14. Hydrophobic Characteristics of Composite Insulators in Simulated Inland Arid Desert Environment

    NASA Astrophysics Data System (ADS)

    Khan, Yasin; Al-Arainy, Abdulrehman Ali; Malik, Nazar Hussain; Qureshi, Muhammad Iqbal

    2010-06-01

    Presently along with traditional insulators i.e. glass and porcelain, etc., the polymeric insulators are also used world widely. These polymeric insulators are very sensitive to various environmental parameters e.g. UV radiations, heat, etc. The UV radiation level in the central region of Saudi Arabia is high as compared to the recommended IEC-61109 standard for the accelerated aging of the composite insulators. In this study, thermoplastic elastomer (TPE) and Ethylene Propylene Diene Monomer (EPDM) insulators were subjected to accelerated aging stress as per IEC standard as well as modified IEC standard simulating the inland arid desert's atmospheric conditions. The hydrophobic characteristics were studied by measuring the contact angle along the insulator surface before and after the accelerated aging of the samples. It was found that TPE loses its hydrophobic properties more as compared to EPDM insulator. This loss was proportional to the intensity of UV irradiation. The rate of recovery is also low for both the tested materials as compared to Silicone Rubber insulators.

  15. Design analysis of ceramic and polymer 150 kV insulators for tropical condition using quickfield software

    NASA Astrophysics Data System (ADS)

    Walukow, Stephy B.; Manjang, Salama; Zainuddin, Zahir; Samman, Faizal Arya

    2018-03-01

    This research is to analyze design of ceramic and polymer 150 kV insulators for the tropical area. The use of an insulator certainly requires an electric field. The leakage current and breakdown voltage this happens the contaminant on the surface of the insulator. This type of contaminant can be rain, dust, salt air, extreme weather (much in tropical climates), industrial pollutants and cracks on the surface resulting in collisions. The method used in this research is magnetic field and electric field isolator using Quicfield software. To get the test results variation ranges 20 kV, 70 kV and 150 kV. Side effects of magnetic and electric fields around the insulator. The simulation results show the accumulated contaminants on the surface. Planning should be done in insulator insulator on unstable insulator. Thus, the approach using this commercially available software can be applied to. Therefore, the development of further simulations on the different types of composite insulators used on.

  16. Advanced Space Suit Insulation Feasibility Study

    NASA Technical Reports Server (NTRS)

    Trevino, Luis A.; Orndoff, Evelyne S.

    2000-01-01

    For planetary applications, the space suit insulation has unique requirements because it must perform in a dynamic mode to protect humans in the harsh dust, pressure and temperature environments. Since the presence of a gaseous planetary atmosphere adds significant thermal conductance to the suit insulation, the current multi-layer flexible insulation designed for vacuum applications is not suitable in reduced pressure planetary environments such as that of Mars. Therefore a feasibility study has been conducted at NASA to identify the most promising insulation concepts that can be developed to provide an acceptable suit insulation. Insulation concepts surveyed include foams, microspheres, microfibers, and vacuum jackets. The feasibility study includes a literature survey of potential concepts, an evaluation of test results for initial insulation concepts, and a development philosophy to be pursued as a result of the initial testing and conceptual surveys. The recommended focus is on microfibers due to the versatility of fiber structure configurations, the wide choice of fiber materials available, the maturity of the fiber processing industry, and past experience with fibers in insulation applications

  17. Effects of insulator ablation on the operation of a quasi-steady MPD arc

    NASA Technical Reports Server (NTRS)

    Boyle, M. J.; Jahn, R. G.

    1973-01-01

    Multimegawatt operation of quasi-steady MPD arcjets can involve serious ablation of the insulator surfaces within the arc discharge chamber. Various degrees of insulator ablation manifest themselves by significantly perturbing the voltage-current characteristics and the exhaust velocity profiles. Voltage-current characteristics for two different insulator materials, Plexiglas and boron nitride, are interpreted in terms of an empirical Ohm's law. Use of the refractory insulator material eliminates the ablation-dominated nature of the terminal voltage, but the exhaust stream is still disturbed by insulator material. An Alfven critical velocity model can be applied to this influence of insulator ablation on exhaust velocity. Appropriate changes in the propellant injection geometry eliminate this influence and result in arcjet operation which is independent of insulator material. A particular combination of propellant injection geometries reduces the terminal voltage for a given current and mass flow while maintaining insulator-independent operation, thus implying an improvement in the overall efficiency of the device.

  18. Lightning Impulse Breakdown Characteristics and Electrodynamic Process of Insulating Vegetable Oil-Based Nanofluid

    NASA Astrophysics Data System (ADS)

    Li, Jian; Zhang, Zhao-Tao; Zou, Ping; Du, Bin; Liao, Rui-Jin

    2012-06-01

    Insulating vegetable oils are considered environment-friendly and fire-resistant substitutes for insulating mineral oils. This paper presents the lightning impulse breakdown characteristic of insulating vegetable oil and insulating vegetable oil-based nanofluids. It indicates that Fe3O4 nanoparticles can increase the negative lightning impulse breakdown voltages of insulating vegetable oil by 11.8% and positive lightning impulse breakdown voltages by 37.4%. The propagation velocity of streamer is reduced by the presence of nanoparticles. The propagation velocities of streamer to positive and negative lightning impulse breakdown in the insulating vegetable oil-based nanofluids are 21.2% and 14.4% lesser than those in insulating vegetable oils, respectively. The higher electrical breakdown strength and lower streamer velocity is explained by the charging dynamics of nanoparticles in insulating vegetable oil. Space charge build-up and space charge distorted filed in point-sphere gap is also described. The field strength is reduced at the streamer tip due to the low mobility of negative nanoparticles.

  19. E(y)2/Sus1 is required for blocking PRE silencing by the Wari insulator in Drosophila melanogaster.

    PubMed

    Erokhin, Maksim; Parshikov, Alexander; Georgiev, Pavel; Chetverina, Darya

    2010-06-01

    Chromatin insulators affect interactions between promoters and enhancers/silencers and function as barriers to the spread of repressive chromatin. Recently, we have found an insulator, named Wari, located on the 3' side of the white gene. Here, we show that the previously identified 368-bp core of this insulator is sufficient for blocking Polycomb response element-mediated silencing. Although Wari does not contain binding sites for known insulator proteins, the E(y)2 and CP190 proteins bind to Wari as well as to the Su(Hw)-containing insulators in vivo. It may well be that these proteins are recruited to the insulator by as yet unidentified DNA-binding protein. Partial inactivation of E(y)2 in a weak e(y)2 ( u1 ) mutation impairs only the anti-silencing but not the enhancer-blocking activity of the Wari insulator. Thus, the E(y)2 protein in different Drosophila insulators serves to protect gene expression from silencing.

  20. Mass Efficiency Considerations for Thermally Insulated Structural Skin of an Aerospace Vehicle

    NASA Technical Reports Server (NTRS)

    Blosser, Max L.

    2012-01-01

    An approximate equation was derived to predict the mass of insulation required to limit the maximum temperature reached by an insulated structure subjected to a transient heating pulse. In the course of the derivation two figures of merit were identified. One figure of merit correlates to the effectiveness of the heat capacity of the underlying structural material in reducing the amount of required insulation. The second figure of merit provides an indicator of the mass efficiency of the insulator material. An iterative, one dimensional finite element analysis was used to size the external insulation required to protect the structure at a single location on the Space Shuttle Orbiter and a reusable launch vehicle. Required insulation masses were calculated for a range of different materials for both structure and insulator. The required insulation masses calculated using the approximate equation were shown to typically agree with finite element results within 10 to 20 percent over the range of parameters studied. Finite element results closely followed the trends indicated by both figures of merit.

  1. Detection of UV Pulse from Insulators and Application in Estimating the Conditions of Insulators

    NASA Astrophysics Data System (ADS)

    Wang, Jingang; Chong, Junlong; Yang, Jie

    2014-10-01

    Solar radiation in the band of 240-280 nm is absorbed by the ozone layer in the atmosphere, and corona discharges from high-voltage apparatus emit in air mainly in the 230-405 nm range of ultraviolet (UV), so the band of 240-280 nm is called UV Solar Blind Band. When the insulators in a string deteriorate or are contaminated, the voltage distribution along the string will change, which causes the electric fields in the vicinity of insulators change and corona discharge intensifies. An UV pulse detection method to check the conditions of insulators is presented based on detecting the UV pulse among the corona discharge, then it can be confirmed that whether there exist faulty insulators and whether the surface contamination of insulators is severe for the safe operation of power systems. An UV-I Insulator Detector has been developed, and both laboratory tests and field tests have been carried out which demonstrates the practical viability of UV-I Insulator Detector for online monitoring.

  2. Hydrophobicity and leakage current statistics of polymeric insulators long-term exposed to coastal contamination

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Soerqvist, T.; Vlastos, A.E.

    1996-12-31

    The hydrophobicity of polymeric insulators is crucial for their performance. This paper reports the hydrophobicity and the peak leakage current statistics of one porcelain, two ethylene-propylene-diene monomer (EPDM) and four silicone rubber (SIR) commercially available insulators. The insulators have been energized with 130 kV rms phase-to-ground AC voltage under identical outdoor conditions for more than seven years. The results presented show that under wet and polluted conditions the hydrophilic EPDM rubber insulators develop high leakage currents and substantial arcing. During a typical salt-storm the arcing amplitude of the EPDM rubber insulators is at least twice as high as that ofmore » the porcelain insulator. The SIR insulators, on the other hand, preserve a high degree of hydrophobicity after more than seven years in service and maintain very low leakage currents. However, the results show that during heavy salt contaminated conditions a highly stressed SIR insulator can temporarily lose its hydrophobicity and thereby develop considerable surface arcing.« less

  3. HYDROPHOBIC CHARACTERISTICS OF COMPOSITE INSULATORS IN SIMULATED INLAND ARID DESERT ENVIRONMENT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Khan, Yasin; Al-Arainy, Abdulrehman Ali; Malik, Nazar Hussain

    2010-06-15

    Presently along with traditional insulators i.e. glass and porcelain, etc., the polymeric insulators are also used world widely. These polymeric insulators are very sensitive to various environmental parameters e.g. UV radiations, heat, etc. The UV radiation level in the central region of Saudi Arabia is high as compared to the recommended IEC-61109 standard for the accelerated aging of the composite insulators. In this study, thermoplastic elastomer (TPE) and Ethylene Propylene Diene Monomer (EPDM) insulators were subjected to accelerated aging stress as per IEC standard as well as modified IEC standard simulating the inland arid desert's atmospheric conditions. The hydrophobic characteristicsmore » were studied by measuring the contact angle along the insulator surface before and after the accelerated aging of the samples. It was found that TPE loses its hydrophobic properties more as compared to EPDM insulator. This loss was proportional to the intensity of UV irradiation. The rate of recovery is also low for both the tested materials as compared to Silicone Rubber insulators.« less

  4. 21 CFR 333.250 - Labeling of antifungal drug products.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... labeled for the treatment of athlete's foot, jock itch, and ringworm. (i) (Select one of the following... more of the following groups of conditions: (A) “Athlete's foot,” athlete's foot (dermatophytosis),” “athlete's foot (tinea pedis),” or “tinea pedis (athlete's foot)”; (B) “Jock itch,” “jock itch (tinea...

  5. 75 FR 78236 - Lock+TM

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-12-15

    ...-foot-wide, 20-foot-deep excavated power canal; (2) a 55-foot-long, 65-foot-wide, 8-foot-deep excavated... 18 CFR 385.2001(a)(1)(iii) and the instructions on the Commission's Web site http://www.ferc.gov/docs... Web site at http://www.ferc.gov/docs-filing/elibrary.asp . Enter the docket number (P-13743-000, 13753...

  6. Low-cost exterior insulation process and structure

    DOEpatents

    Vohra, A.

    1999-03-02

    A low-cost exterior insulation process of stacking bags of insulating material against a wall and covering them with wire mesh and stucco provides a durable structure with good insulating value. 2 figs.

  7. Insulation Materials Comprising Fibers Having a Partially Cured Polymer Coating Thereon, Articles Including Such Insulation Materials, and Methods of Forming Such Materials and Articles

    NASA Technical Reports Server (NTRS)

    Morgan, Richard E. (Inventor); Meeks, Craig L. (Inventor)

    2017-01-01

    Insulation materials have a coating of a partially cured polymer on a plurality of fibers, and the plurality of coated fibers in a cross-linked polymeric matrix. Insulation may be formed by applying a preceramic polymer to a plurality of fibers, heating the preceramic polymer to form a partially cured polymer over at least portions of the plurality of fibers, disposing the plurality of fibers in a polymeric material, and curing the polymeric material. A rocket motor may be formed by disposing a plurality of coated fibers in an insulation precursor, curing the insulation precursor to form an insulation material without sintering the partially cured polymer, and providing an energetic material over the polymeric material. An article includes an insulation material over at least one surface.

  8. Biophysical evaluation of footwear for cold-weather climates.

    PubMed

    Santee, W R; Endrusick, T L

    1988-02-01

    Proper selection of footwear for cold-wet environments is important in determining individual performance and comfort. Testing only total dry insulation (It) is not a wholly adequate basis for boot selection. The present study demonstrates an effective method for evaluating the effects of surface moisture on boot insulation. This method allows a more knowledgeable selection of footwear for cold-wet climates. In this study, regional insulation values were obtained under dry conditions, then during a soak in shallow water, and finally for insulation recovery after removal from water. Results for seven boots show no advantage of presently used synthetic materials during short soak episodes. Insulated leather-synthetic boots, however, recovered to dry insulation levels more rapidly than more traditional insulated leather boots. Rubber waterproof bottoms were the most effective boot construction for retaining insulation levels during water exposure.

  9. Using geothermal energy to heat a portion of a formation for an in situ heat treatment process

    DOEpatents

    Pieterson, Roelof; Boyles, Joseph Michael; Diebold, Peter Ulrich

    2010-06-08

    Methods of using geothermal energy to treat subsurface formations are described herein. Methods for using geothermal energy to treat a subsurface treatment area containing or proximate to hydrocarbons may include producing geothermally heated fluid from at least one subsurface region. Heat from at least a portion of the geothermally heated fluid may be transferred to the subsurface treatment area to heat the subsurface treatment area. At least some hydrocarbon fluids may be produced from the formation.

  10. [The gold standard in diabetic foot treatment: total contact cast].

    PubMed

    Lozano-Platonoff, Adriana; Florida Mejía-Mendoza, Melissa Desireé; Ibáñez-Doria, Mónica; Contreras-Ruiz, José

    2014-01-01

    In patients with diabetes, foot complications remain one of the main health issues, with ulcers representing one of the most common. These ulcerations originate from repetitive trauma on a foot with neuropathy. Inadequate care of the diabetic foot may lead to one of the gravest complications of the diabetic foot: amputation. The key to the treatment of the diabetic foot is the control of comorbidities (glucose levels and vascular disease), debridement, exudate control with the available modern dressings, treatment of infection, and offloading the affected foot. A common error in this basic treatment is the method used for offloading, leading to delayed healing as a result, and maybe even amputation. For this purpose we propose the total contact cast considered the "gold standard" in diabetic foot offloading. The objective of the present review is to present the existing evidence in the medical literature on the effectiveness of its use for healing diabetic foot ulcers and hence preventing amputations.

  11. Starting off on the right foot: strong right-footers respond faster with the right foot to positive words and with the left foot to negative words

    PubMed Central

    de la Vega, Irmgard; Graebe, Julia; Härtner, Leonie; Dudschig, Carolin; Kaup, Barbara

    2015-01-01

    Recent studies have provided evidence for an association between valence and left/right modulated by handedness, which is predicted by the body-specificity hypothesis (Casasanto, 2009) and also reflected in response times. We investigated whether such a response facilitation can also be observed with foot responses. Right-footed participants classified positive and negative words according to their valence by pressing a key with their left or right foot. A significant interaction between valence and foot only emerged in the by-items analysis. However, when dividing participants into two groups depending on the strength of their footedness, an interaction between valence and left/right was observed for strong right-footers, who responded faster with the right foot to positive words, and with the left foot to negative words. No interaction emerged for weak right-footers. The results strongly support the assumption that fluency lies at the core of the association between valence and left/right. PMID:25852609

  12. A Cochrane review of the evidence for non-surgical interventions for flexible pediatric flat feet.

    PubMed

    Evans, A M; Rome, K

    2011-03-01

    The pediatric flat foot is a frequent presentation in clinical practice, a common concern to parents and continues to be debated within professional ranks. As an entity, it is confused by varied classifications, the notion of well-intended prevention and unsubstantiated, if common, treatment. The available prevalence estimates are all limited by variable sampling, assessment measures and age groups and hence result in disparate findings (0.6-77.9%). Consistently, flat foot has been found to normally reduce with age. The normal findings of flat foot versus children's age estimates that approximately 45% of preschool children, and 15% of older children (average age 10 years) have flat feet. Few flexible flat feet have been found to be symptomatic. Joint hypermobility and increased weight or obesity may increase flat foot prevalence, independently of age. Most attempts at classification of flat foot morphology include the arch, heel position and foot flexibility. Usual assessment methods are footprint measures, X-rays and visual (scaled) observations. There is no standardized framework from which to evaluate the pediatric flat foot. The pediatric flat foot is often unnecessarily treated, being ill-defined and of uncertain prognosis. Contemporary management of the pediatric flat foot is directed algorithmically within this review, according to pain, age, flexibility; considering gender, weight, and joint hypermobility. When foot orthoses are indicated, inexpensive generic appliances will usually suffice. Customised foot orthoses should be reserved for children with foot pain and arthritis, for unusual morphology, or unresponsive cases. Surgery is rarely indicated for pediatric flat foot (unless rigid) and only at the failure of thorough conservative management. The assessment of the pediatric flatfoot needs to be considered with reference to the epidemiological findings, where there is consensus that pediatric flexible flat foot reduces with age and that most children are asymptomatic. Globally, there is need for a standard by which the pediatric flat foot is assessed classified and managed. Until then, assessment should utilize the available evidence-based management model, the p-FFP Future research needs to evaluate the pediatric flat foot from representative samples, of healthy and known disease-group children prospectively, and using validated assessment instruments. The preliminary findings of the benefits of foot exercises, and discrete investigation into the effects of shoes and footwear use are also warranted.

  13. Patterns of foot complaints in systemic lupus erythematosus: a cross sectional survey.

    PubMed

    Otter, Simon J; Kumar, Sunil; Gow, Peter; Dalbeth, Nicola; Corkill, Michael; Rohan, Maheswaran; Davies, Kevin A; Pankathelam, Sam; Rome, Keith

    2016-01-01

    Foot complaints are common in inflammatory arthropathies such as rheumatoid arthritis and cause considerable disability. However, little is published about the nature and extent of foot complaints in systemic lupus erythematosus (SLE). We aimed to explore foot complaints among people with (SLE) and to evaluate the associations between foot pain and self-reported activities of daily living and well-being. We developed and tested a new 40-item item self-administered questionnaire, using a five-stage development process utilising patient involvement throughout to ensure face and content validity. The self-administered instrument was posted to 406 people with SLE attending adult rheumatology clinics across three health boards in Auckland, New Zealand. The questionnaire enquired about symptoms of foot pain, extra-articular features, anatomical distribution of symptoms according to validated foot-mannequins and the impact of foot symptoms on activities of daily living and well-being. In total, 406 questionnaires were posted, with 131 responses (response rate 32 %). We found 89 % were women, mean (SD) age 51 (15) years, mean (SD) diagnosis 12.5 (11.1) years. Overall, 77 % of those responding to the questionnaire reported foot pain during their SLE, with 45 % reporting current foot pain. All regions of the feet were affected, with the hindfoot (32 %) and ankles (30 %) most troublesome. The most common self-reported extra-articular foot complaints were cold feet, swelling and numbness. Almost two-thirds (61 %) reported foot pain adversely affected their lives; foot pain prevented sleeping in 36 % and had a negative effect on emotions for 33 %. Only 33 % of participants had seen a podiatrist. Significant association was found between foot pain and standing longer than 15 min (p < 0.001), walking (p < 0.001), climbing stairs (p < 0.001) and going shopping (p < 0.001). Pain was the primary symptom to affect quality of life (47/100). Foot complaints in SLE are heterogeneous in nature, and may have a substantial negative impact on patient well-being. Foot complaints need to be addressed to reduce the burden of SLE and our findings support the need for wider access to specific foot care services.

  14. The effect of foot orthotic use on exercise related leg pain in cross country athletes.

    PubMed

    Reinking, Mark F; Hayes, Ann M; Austin, Tricia M

    2012-11-01

    The purposes of this research were to (1) investigate the effect of foot orthotic use on exercise related leg pain (ERLP) in cross-country (XC) athletes, and (2) determine if an association between foot type and foot orthotic use exists. Prospective cohort design. High schools and colleges in a Midwestern metropolitan region. 213 high school and college XC athletes (107 male, 106 female). Participants were seen before the fall XC season for classification of foot type, visual orthotic inspection, and questionnaire completion regarding foot orthotic use and ERLP. Statistical analysis of relationships (chi-square) was conducted. 37 of the 213 XC athletes (17.4%) used foot orthotics; 31 of the 37 athletes using foot orthotics (83.8%) reported a history of ERLP. Of these 31 athletes, 17 (54.8%) were using orthotics for ERLP and 15 reported a decrease in ERLP with orthotic use. Fourteen athletes were using orthotics for a reason other than ERLP and only 2 reported a decrease in ERLP with orthotic use. Athletes using orthotics included all three foot types (pronated, neutral, supinated) with no relationship between orthotic use and foot type. One-sixth of the XC athletes used foot orthotics and most using orthotics for ERLP reported a decrease in ERLP symptoms. The majority of athletes using orthotics for reasons other than ERLP reported no change in ERLP symptoms. There was no association between foot type and orthotic use. Copyright © 2011 Elsevier Ltd. All rights reserved.

  15. Are in-shoe pressure characteristics in symptomatic idiopathic pes cavus related to the location of foot pain?

    PubMed

    Crosbie, Jack; Burns, Joshua

    2008-01-01

    People who have extremely high arched feet may be subject to substantial levels of foot pain, despite the lack of obvious pathology. This study sought to investigate the effect of pes cavus on pain intensity and location and on the magnitude and distribution of foot pressure. Measurements were derived from the more symptomatic foot of 130 participants with painful, idiopathic pes cavus. Data were collected using Pedar in-shoe pressure sensors and averaged over nine randomly selected steps. Participant information, including location and intensity of pain, Foot Posture Index values and anthropometric and "quality of life" variables, were also recorded. Painful idiopathic pes cavus seems to provoke a more cautious gait pattern than normal, with reduced peak and mean pressure values, particularly in the fore- and rear-foot regions. In particular, participants with pain confined to the rear-foot exhibit an antalgic gait pattern, with lower pressure values and a longer period of foot-ground contact in the heel region than those with pain only in the fore-foot. We determined no clear predictors of pain in terms of foot posture or demographics, although people with high body mass index values are more likely to have pain in several regions. The relationship between the posture of the foot and the presentation of pain remains unclear, however we believe that the presence of heel pain in pes cavus may be more restricting than fore-foot pain.

  16. New devices for measuring forces on the kayak foot bar and on the seat during flat-water kayak paddling: a technical report.

    PubMed

    Nilsson, Johnny E; Rosdahl, Hans G

    2014-03-01

    The purpose was to develop and validate portable force-measurement devices for recording push and pull forces applied by each foot to the foot bar of a kayak and the horizontal force at the seat. A foot plate on a single-point force transducer mounted on the kayak foot bar underneath each foot allowed the push and pull forces to be recorded. Two metal frames interconnected with 4 linear ball bearings, and a force transducer allowed recording of horizontal seat force. The foot-bar-force device was calibrated by loading each foot plate with weights in the push-pull direction perpendicular to the foot plate surface, while the seat-force device was calibrated to horizontal forces with and without weights on the seat. A strong linearity (r2 = .99-1.0) was found between transducer output signal and load force in the push and pull directions for both foot-bar transducers perpendicular to the foot plate and the seat-force-measuring device. Reliability of both devices was tested by means of a test-retest design. The coefficient of variation (CV) for foot-bar push and pull forces ranged from 0.1% to 1.1%, and the CV for the seat forces varied from 0.6% to 2.2%. The current study opens up a field for new investigations of the forces generated in the kayak and ways to optimize kayak-paddling performance.

  17. Development and validation of purged thermal protection systems for liquid hydrogen fuel tanks of hypersonic vehicles

    NASA Technical Reports Server (NTRS)

    Helenbrook, R. D.; Colt, J. Z.

    1977-01-01

    An economical, lightweight, safe, efficient, reliable, and reusable insulation system was developed for hypersonic cruise vehicle hydrogen fuel tanks. Results indicate that, a nitrogen purged, layered insulation system with nonpermeable closed-cell insulation next to the cryogenic tank and a high service temperature fibrous insulation surrounding it, is potentially an attractive solution to the insulation problem. For the postulated hypersonic flight the average unit weight of the purged insulation system (including insulation, condensate and fuel boil off) is 6.31 kg/sq m (1.29 psf). Limited cyclic tests of large specimens of closed cell polymethacrylimide foam indicate it will withstand the expected thermal cycle.

  18. Physical properties of Ce-TZP at cryogenic temperature

    NASA Astrophysics Data System (ADS)

    Han, Y. M.; Chen, Z.; Zhou, M.; Huang, R. J.; Huang, C. J.; Li, L. F.

    2014-01-01

    Electrical insulators, which are used to insulate cryogenic supply lines and conductor windings, are critical units in superconducting TOKAMAK magnets. Electrical insulators used in superconducting magnets fall into axial and radial insulators. These insulators can be made from glass ribbon epoxy densification and have been used in the Experiment Advanced Superconducting Tokamak (EAST). The properties of Ce-TZP can satisfy the requirement of electrical insulators. In this paper, thermal conductivity, mechanical properties and coefficient of thermal expansion of Ce-TZP have been investigated at cryogenic temperatures. Results indicate that the Ce-TZP shows better properties than epoxy and it demonstrates that the Ce-TZP can be used as insulation material in superconducting magnets.

  19. Hydrogen storage in insulated pressure vessels

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Aceves, S.M.; Garcia-Villazana, O.

    1998-08-01

    Insulated pressure vessels are cryogenic-capable pressure vessels that can be fueled with liquid hydrogen (LH{sub 2}) or ambient-temperature compressed hydrogen (CH{sub 2}). Insulated pressure vessels offer the advantages of liquid hydrogen tanks (low weight and volume), with reduced disadvantages (lower energy requirement for hydrogen liquefaction and reduced evaporative losses). This paper shows an evaluation of the applicability of the insulated pressure vessels for light-duty vehicles. The paper shows an evaluation of evaporative losses and insulation requirements and a description of the current analysis and experimental plans for testing insulated pressure vessels. The results show significant advantages to the use ofmore » insulated pressure vessels for light-duty vehicles.« less

  20. tDNA insulators and the emerging role of TFIIIC in genome organization

    PubMed Central

    Van Bortle, Kevin; Corces, Victor G.

    2012-01-01

    Recent findings provide evidence that tDNAs function as chromatin insulators from yeast to humans. TFIIIC, a transcription factor that interacts with the B-box in tDNAs as well as thousands of ETC sites in the genome, is responsible for insulator function. Though tDNAs are capable of enhancer-blocking and barrier activities for which insulators are defined, new insights into the relationship between insulators and chromatin structure suggest that TFIIIC serves a complex role in genome organization. We review the role of tRNA genes and TFIIIC as chromatin insulators, and highlight recent findings that have broadened our understanding of insulators in genome biology. PMID:22889843

  1. Attic Retrofits Using Nail-Base Insulated Panels

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mallay, David; Kochkin, Vladimir

    This project developed and demonstrated a roof/attic energy retrofit solution using nail-base insulated panels for existing homes where traditional attic insulation approaches are not effective or feasible. Nail-base insulated panels (retrofit panels) consist of rigid foam insulation laminated to one face of a wood structural panel. The prefabricated panels are installed above the existing roof deck during a reroofing effort.

  2. Influence of copper on the by-products of different oil-paper insulations

    NASA Astrophysics Data System (ADS)

    Hao, Jian; Liao, Ruijin; Chen, George; Ma, Chao

    2011-08-01

    Transformer failure caused by the corrosion of copper material in transformer attracts great attention of researchers and engineers. In this paper, Karamay No. 25 naphthenic mineral oil, Karamay No. 25 paraffinic mineral oil, Kraft paper and copper were used to compose four combinations of oil-paper insulation samples. The ageing by-products and dielectric properties of the four combinations of oil-paper insulation samples were compared after they were thermally aged at 130°C. The influence of copper on the by-products and dielectric properties of different oil-paper insulations was obtained. The results show that copper can accelerate the ageing rate of insulation oils and reduce their AC breakdown voltage. The content of copper substance dissolved in insulating oil increases with ageing time at first and then decreases. The paper aged in the oil-paper insulation sample with copper has higher moisture content than the one without copper. Results of energy dispersive spectroscopy (EDS) in the scanning electron microscope (SEM) show that there is copper product deposited on the surface of insulation paper. The insulation oil and paper aged in the oil-paper insulation sample with copper have higher dielectric loss and conductivity than that without copper.

  3. The RNA-binding protein Rumpelstiltskin antagonizes gypsy chromatin insulator function in a tissue-specific manner

    PubMed Central

    King, Matthew R.; Matzat, Leah H.; Dale, Ryan K.; Lim, Su Jun; Lei, Elissa P.

    2014-01-01

    ABSTRACT Chromatin insulators are DNA–protein complexes that are situated throughout the genome that are proposed to contribute to higher-order organization and demarcation into distinct transcriptional domains. Mounting evidence in different species implicates RNA and RNA-binding proteins as regulators of chromatin insulator activities. Here, we identify the Drosophila hnRNP M homolog Rumpelstiltskin (Rump) as an antagonist of gypsy chromatin insulator enhancer-blocking and barrier activities. Despite ubiquitous expression of Rump, decreasing Rump levels leads to improvement of barrier activity only in tissues outside of the central nervous system (CNS). Furthermore, rump mutants restore insulator body localization in an insulator mutant background only in non-CNS tissues. Rump associates physically with core gypsy insulator proteins, and chromatin immunoprecipitation and sequencing analysis of Rump demonstrates extensive colocalization with a subset of insulator sites across the genome. The genome-wide binding profile and tissue specificity of Rump contrast with that of Shep, a recently identified RNA-binding protein that antagonizes gypsy insulator activity primarily in the CNS. Our findings indicate parallel roles for RNA-binding proteins in mediating tissue-specific regulation of chromatin insulator activity. PMID:24706949

  4. Theoretical analysis of three methods for calculating thermal insulation of clothing from thermal manikin.

    PubMed

    Huang, Jianhua

    2012-07-01

    There are three methods for calculating thermal insulation of clothing measured with a thermal manikin, i.e. the global method, the serial method, and the parallel method. Under the condition of homogeneous clothing insulation, these three methods yield the same insulation values. If the local heat flux is uniform over the manikin body, the global and serial methods provide the same insulation value. In most cases, the serial method gives a higher insulation value than the global method. There is a possibility that the insulation value from the serial method is lower than the value from the global method. The serial method always gives higher insulation value than the parallel method. The insulation value from the parallel method is higher or lower than the value from the global method, depending on the relationship between the heat loss distribution and the surface temperatures. Under the circumstance of uniform surface temperature distribution over the manikin body, the global and parallel methods give the same insulation value. If the constant surface temperature mode is used in the manikin test, the parallel method can be used to calculate the thermal insulation of clothing. If the constant heat flux mode is used in the manikin test, the serial method can be used to calculate the thermal insulation of clothing. The global method should be used for calculating thermal insulation of clothing for all manikin control modes, especially for thermal comfort regulation mode. The global method should be chosen by clothing manufacturers for labelling their products. The serial and parallel methods provide more information with respect to the different parts of clothing.

  5. Estimation of subsurface thermal structure using sea surface height and sea surface temperature

    NASA Technical Reports Server (NTRS)

    Kang, Yong Q. (Inventor); Jo, Young-Heon (Inventor); Yan, Xiao-Hai (Inventor)

    2012-01-01

    A method of determining a subsurface temperature in a body of water is disclosed. The method includes obtaining surface temperature anomaly data and surface height anomaly data of the body of water for a region of interest, and also obtaining subsurface temperature anomaly data for the region of interest at a plurality of depths. The method further includes regressing the obtained surface temperature anomaly data and surface height anomaly data for the region of interest with the obtained subsurface temperature anomaly data for the plurality of depths to generate regression coefficients, estimating a subsurface temperature at one or more other depths for the region of interest based on the generated regression coefficients and outputting the estimated subsurface temperature at the one or more other depths. Using the estimated subsurface temperature, signal propagation times and trajectories of marine life in the body of water are determined.

  6. Defining the Post-Machined Sub-surface in Austenitic Stainless Steels

    NASA Astrophysics Data System (ADS)

    Srinivasan, N.; Sunil Kumar, B.; Kain, V.; Birbilis, N.; Joshi, S. S.; Sivaprasad, P. V.; Chai, G.; Durgaprasad, A.; Bhattacharya, S.; Samajdar, I.

    2018-04-01

    Austenitic stainless steels grades, with differences in chemistry, stacking fault energy, and thermal conductivity, were subjected to vertical milling. Anodic potentiodynamic polarization was able to differentiate (with machining speed/strain rate) between different post-machined sub-surfaces in SS 316L and Alloy A (a Cu containing austenitic stainless steel: Sanicroe 28™), but not in SS 304L. However, such differences (in the post-machined sub-surfaces) were revealed in surface roughness, sub-surface residual stresses and misorientations, and in the relative presence of sub-surface Cr2O3 films. It was shown, quantitatively, that higher machining speed reduced surface roughness and also reduced the effective depths of the affected sub-surface layers. A qualitative explanation on the sub-surface microstructural developments was provided based on the temperature-dependent thermal conductivity values. The results herein represent a mechanistic understanding to rationalize the corrosion performance of widely adopted engineering alloys.

  7. Inter-comparison of Methods for Extracting Subsurface Layers from SHARAD Radargrams over Martian polar regions

    NASA Astrophysics Data System (ADS)

    Xiong, S.; Muller, J.-P.; Carretero, R. C.

    2017-09-01

    Subsurface layers are preserved in the polar regions on Mars, representing a record of past climate changes on Mars. Orbital radar instruments, such as the Mars Advanced Radar for Subsurface and Ionosphere Sounding (MARSIS) onboard ESA Mars Express (MEX) and the SHAllow RADar (SHARAD) onboard the Mars Reconnaissance Orbiter (MRO), transmit radar signals to Mars and receive a set of return signals from these subsurface regions. Layering is a prominent subsurface feature, which has been revealed by both MARSIS and SHARAD radargrams over both polar regions on Mars. Automatic extraction of these subsurface layering is becoming increasingly important as there is now over ten years' of data archived. In this study, we investigate two different methods for extracting these subsurface layers from SHARAD data and compare the results against delineated layers derived manually to validate which methods is better for extracting these layers automatically.

  8. Reduction of the 355-nm laser-induced damage initiators by removing the subsurface cracks in fused silica

    NASA Astrophysics Data System (ADS)

    Yang, Minghong; Qi, Hongji; Zhao, Yuanan; Yi, Kui

    2012-01-01

    The 355 nm laser-induced damage thresholds (LIDTs) of polished fused silica with and without the residual subsurface cracks were explored. HF based wet etching and magnetorheological finishing was used to remove the subsurface cracks. To isolate the effect of subsurface cracks, chemical leaching was used to eliminate the photoactive impurities in the polishing layer. Results show that the crack number density decreased from~103 to <1cm-2, and the LIDT was improved as high as 2.8-fold with both the subsurface cracks and the polishing layer being removed. Subsurface cracks play a significant role in laser damage at fluencies between 15~31 J/cm2 (355nm, 8ns). HF Etching of the cracks was shown to increase the damage performance as nearly high as that of the samples in which subsurface cracks are well controlled.

  9. Defining the Post-Machined Sub-surface in Austenitic Stainless Steels

    NASA Astrophysics Data System (ADS)

    Srinivasan, N.; Sunil Kumar, B.; Kain, V.; Birbilis, N.; Joshi, S. S.; Sivaprasad, P. V.; Chai, G.; Durgaprasad, A.; Bhattacharya, S.; Samajdar, I.

    2018-06-01

    Austenitic stainless steels grades, with differences in chemistry, stacking fault energy, and thermal conductivity, were subjected to vertical milling. Anodic potentiodynamic polarization was able to differentiate (with machining speed/strain rate) between different post-machined sub-surfaces in SS 316L and Alloy A (a Cu containing austenitic stainless steel: Sanicroe 28™), but not in SS 304L. However, such differences (in the post-machined sub-surfaces) were revealed in surface roughness, sub-surface residual stresses and misorientations, and in the relative presence of sub-surface Cr2O3 films. It was shown, quantitatively, that higher machining speed reduced surface roughness and also reduced the effective depths of the affected sub-surface layers. A qualitative explanation on the sub-surface microstructural developments was provided based on the temperature-dependent thermal conductivity values. The results herein represent a mechanistic understanding to rationalize the corrosion performance of widely adopted engineering alloys.

  10. Total Internal Reflection Microscopy (TIRM) as a nondestructive surface damage assessment tool

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liao, Z.M.; Cohen, S.J.; Taylor, J.R.

    1994-10-01

    An easy to use, nondestructive, method for evaluating subsurface damage in polished substrates has been established at LLNL. Subsurface damage has been related to laser damage in coated optical components used in high power, high repetition rate laser systems. Total Internal Reflection Microscopy (TIRM) has been shown to be a viable nondestructive technique in analyzing subsurface damage in optical components. A successful TIRM system has been established for evaluating subsurface damage on fused silica components. Laser light scattering from subsurface damage sites is collected through a Nomarski microscope. These images are then captured by a CCD camera for analysis onmore » a computer. A variety of optics, including components with intentional subsurface damage due to grinding and polishing, have been analyzed and their TIRM images compared to an existing destructive etching method. Methods for quantitative measurement of subsurface damage are also discussed.« less

  11. Crystal structure of laser-induced subsurface modifications in Si

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Verburg, P. C.; Smillie, L. A.; Römer, G. R. B. E.

    2015-06-04

    Laser-induced subsurface modification of dielectric materials is a well-known technology. Applications include the production of optical components and selective etching. In addition to dielectric materials, the subsurface modification technology can be applied to silicon, by employing near to mid-infrared radiation. An application of subsurface modifications in silicon is laser-induced subsurface separation, which is a method to separate wafers into individual dies. Other applications for which proofs of concept exist are the formation of waveguides and resistivity tuning. However, limited knowledge is available about the crystal structure of subsurface modifications in silicon. In this paper, we investigate the geometry and crystalmore » structure of laser-induced subsurface modifications in monocrystalline silicon wafers. Finally, in addition to the generation of lattice defects, we found that transformations to amorphous silicon and Si-iii/Si-xii occur as a result of the laser irradiation.« less

  12. Search for life on Mars.

    PubMed

    Brack, A; Clancy, P; Fitton, B; Hoffmann, B; Horneck, G; Kurat, G; Maxwell, J; Ori, G; Pillinger, C; Raulin, F; Thomas, N; Westall, F

    1998-06-01

    A multi-user integrated suite of instruments designed to optimize the search for evidence of life on Mars is described. The package includes: -Surface inspection and surface environment analysis to identify the potential Mars landing sites, to inspect the surface geology and mineralogy, to search for visible surficial microbial macrofossils, to study the surface radiation budget and surface oxidation processes, to search for niches for extant life. -Subsurface sample acquisition by core drilling -Analysis of surface and subsurface minerals and organics to characterize the surface mineralogy, to analyse the surface and subsurface oxidants, to analyse the mineralogy of subsurface aliquots, to analyse the organics present in the subsurface aliquots (elemental and molecular composition, isotopes, chirality). -Macroscopic and microscopic inspection of subsurface aliquots to search for life's indicators (paleontological, biological, mineralogical) and to characterize the mineralogy of the subsurface aliquots. The study is led by ESA Manned Spaceflight and Microgravity Directorate.

  13. Electrical wire insulation and electromagnetic coil

    DOEpatents

    Bich, George J.; Gupta, Tapan K.

    1984-01-01

    An electromagnetic coil for high temperature and high radiation application in which glass is used to insulate the electrical wire. A process for applying the insulation to the wire is disclosed which results in improved insulation properties.

  14. Robust Foot Clearance Estimation Based on the Integration of Foot-Mounted IMU Acceleration Data

    PubMed Central

    Benoussaad, Mourad; Sijobert, Benoît; Mombaur, Katja; Azevedo Coste, Christine

    2015-01-01

    This paper introduces a method for the robust estimation of foot clearance during walking, using a single inertial measurement unit (IMU) placed on the subject’s foot. The proposed solution is based on double integration and drift cancellation of foot acceleration signals. The method is insensitive to misalignment of IMU axes with respect to foot axes. Details are provided regarding calibration and signal processing procedures. Experimental validation was performed on 10 healthy subjects under three walking conditions: normal, fast and with obstacles. Foot clearance estimation results were compared to measurements from an optical motion capture system. The mean error between them is significantly less than 15% under the various walking conditions. PMID:26703622

  15. Foot Plantar Pressure Measurement System: A Review

    PubMed Central

    Razak, Abdul Hadi Abdul; Zayegh, Aladin; Begg, Rezaul K.; Wahab, Yufridin

    2012-01-01

    Foot plantar pressure is the pressure field that acts between the foot and the support surface during everyday locomotor activities. Information derived from such pressure measures is important in gait and posture research for diagnosing lower limb problems, footwear design, sport biomechanics, injury prevention and other applications. This paper reviews foot plantar sensors characteristics as reported in the literature in addition to foot plantar pressure measurement systems applied to a variety of research problems. Strengths and limitations of current systems are discussed and a wireless foot plantar pressure system is proposed suitable for measuring high pressure distributions under the foot with high accuracy and reliability. The novel system is based on highly linear pressure sensors with no hysteresis. PMID:23012576

  16. Ceramic insulation/multifoil composite for thermal protection of reentry spacecraft

    NASA Technical Reports Server (NTRS)

    Pitts, W. C.; Kourtides, D. A.

    1989-01-01

    A new type of insulation blanket called Composite Flexible Blanket Insulation is proposed for thermal protection of advanced spacecraft in regions where the maximum temperature is not excessive. The blanket is a composite of two proven insulation materials: ceramic insulation blankets from Space Shuttle technology and multilayer insulation blankets from spacecraft thermal control technology. A potential heatshield weight saving of up to 500 g/sq m is predicted. The concept is described; proof of concept experimental data are presented; and a spaceflight experiment to demonstrate its actual performance is discussed.

  17. Study on Insulation Diagnosis of Power Lines in Apartment Houses

    NASA Astrophysics Data System (ADS)

    Okamoto, Tatsuki; Taki, Shoji; Fukui, Toshiaki; Soga, Akiya; Ezure, Shoichiro; Asano, Jun-Ichi; Uto, Yukio

    Insulation diagnosis is vital issue for safety of urban lives despite of the difficulty of power interruption even for the diagnosis. Recently, live-line insulation diagnosis becomes more important and realistic to maintain good insulation conditions of power lines in apartment houses in wide range of residential sizes. This paper describes new trend of insulation diagnosis of power lines of apartment houses based on clip-on current measurement method with a lot of live-line measurement data and also describes the applicability of new live-line insulation diagnostic method.

  18. 78 FR 17649 - Western Minnesota Municipal Power Agency; FFP Qualified Hydro 14, LLC; Notice of Competing...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-22

    ... the proposed turbines; (6) a new 120-foot-long by 70-foot-wide concrete powerhouse, containing three 4.8-MW Kaplan turbine-generators, with a combined nameplate capacity of 14.4 MW; (7) a new 275-foot...) a new 100-foot-long by 50-foot-wide concrete powerhouse with three 5-megawatt (MW) turbines, having...

  19. 76 FR 64933 - Alaska Power Company, Inc.; Notice of Preliminary Permit Application Accepted for Filing and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-10-19

    ...-wide powerhouse containing one 4.1-megawatt (MW) turbine/generator unit with an adjacent 40-foot-long...-foot-wide powerhouse containing one 4.8-MW turbine/generator unit with an adjacent 40-foot-long, 40... powerhouse containing one 0.9-MW turbine/generator unit with an adjacent 30-foot-long, 40-foot-wide...

  20. The Relationship with Balance, Foot Posture, and Foot Size in School of Physical Education and Sports Students

    ERIC Educational Resources Information Center

    Irez, Gonul Babayigit

    2014-01-01

    The aim of this study is to investigate the relationship of foot posture and foot size with balance. A hundred and thirteen healthy volunteers were recruited from undergraduate students (Male = 74, Female = 37, age range 18-22). The Foot Posture Index (FPI-6), anthropometric measurements, dynamic balance and static balance measurements were done…

Top