Effect of Foot Progression Angle and Lateral Wedge Insole on a Reduction in Knee Adduction Moment.
Tokunaga, Ken; Nakai, Yuki; Matsumoto, Ryo; Kiyama, Ryoji; Kawada, Masayuki; Ohwatashi, Akihiko; Fukudome, Kiyohiro; Ohshige, Tadasu; Maeda, Tetsuo
2016-10-01
This study evaluated the effect of foot progression angle on the reduction in knee adduction moment caused by a lateral wedged insole during walking. Twenty healthy, young volunteers walked 10 m at their comfortable velocity wearing a lateral wedged insole or control flat insole in 3 foot progression angle conditions: natural, toe-out, and toe-in. A 3-dimensional rigid link model was used to calculate the external knee adduction moment, the moment arm of ground reaction force to knee joint center, and the reduction ratio of knee adduction moment and moment arm. The result indicated that the toe-out condition and lateral wedged insole decreased the knee adduction moment in the whole stance phase. The reduction ratio of the knee adduction moment and the moment arm exhibited a close relationship. Lateral wedged insoles decreased the knee adduction moment in various foot progression angle conditions due to decrease of the moment arm of the ground reaction force. Moreover, the knee adduction moment during the toe-out gait with lateral wedged insole was the smallest due to the synergistic effect of the lateral wedged insole and foot progression angle. Lateral wedged insoles may be a valid intervention for patients with knee osteoarthritis regardless of the foot progression angle.
Cho, Yumi; Kim, Minkyu; Lee, Wanhee
2015-01-01
[Purpose] The purpose of this study was to determine the effect of proprioceptive training on foot progression angle, weight-bearing ratio, and knee adduction moment in patients with degenerative osteoarthritis of the knee. [Subjects] The subjects were 37 patients diagnosed with Kellgren-Lawrence grade 2 or 3 degenerative knee osteoarthritis. They were randomly allocated to three groups: a proprioceptive training group (PT group), quadriceps strengthening group (QS group), and control group. [Methods] The study parameters of the three groups were compared before and after a 12-week training period. Therapeutic exercises were performed twice per week for 12 weeks. Outcomes included the foot progression angle, weight-bearing ratio, and knee adduction moment. [Results] First, a significant difference in the foot progression angle was observed among the groups, significantly increasing in the PTG compared with the CG. Second, a significant difference in the weight-bearing ratio was observed among the groups, significantly increasing in the PTG compared with the CG. Third, a significant difference in the first peak knee adduction moment was observed among the groups, significantly decreasing in the PTG compared with the CG. [Conclusion] The results of the present study indicate that proprioceptive training increased the foot progression angle and weight-bearing ratio and decreased the first peak knee adduction moment. Moreover, incorporating proprioceptive training into a physical therapy exercise program could improve functional ability and delay the progression of degenerative osteoarthritis. PMID:25729170
Major, Matthew J; Howard, David; Jones, Rebecca; Twiste, Martin
2012-06-01
Unlike sagittal plane prosthesis alignment, few studies have observed the effects of transverse plane alignment on gait and prosthesis behaviour. Changes in transverse plane rotation angle will rotate the points of loading on the prosthesis during stance and may alter its mechanical behaviour. This study observed the effects of increasing the external transverse plane rotation angle, or toe-out, on foot compression and effective lever arm of three commonly prescribed prosthetic feet. The roll-over shape of a SACH, Flex and single-axis foot was measured at four external rotation angle conditions (0°, 5°, 7° and 12° relative to neutral). Differences in foot compression between conditions were measured as average distance between roll-over shapes. Increasing the transverse plane rotation angle did not affect foot compression. However, it did affect the effective lever arm, which was maximized with the 5° condition, although differences between conditions were small. Increasing the transverse plane rotation angle of prosthetic feet by up to 12° beyond neutral has minimal effects on their mechanical behaviour in the plane of walking progression during weight-bearing.
Relationship between foot posture and dental malocclusions in children aged 6 to 9 years
Marchena-Rodríguez, Ana; Moreno-Morales, Noelia; Ramírez-Parga, Edith; Labajo-Manzanares, María Teresa; Luque-Suárez, Alejandro; Gijon-Nogueron, Gabriel
2018-01-01
Abstract The aim of this study was to determine the association, if any, between foot posture and dental malocclusions in the anteroposterior plane, in children. The study population consisted of 189 children (95 boys and 94 girls) aged 6 to 9 years. In every case, previous informed consent was requested and obtained from the parent/guardian and the study was approved by the Ethics Committee of the University of Málaga (CEUMA 26/2015H). This observational, descriptive, cross-sectional analysis is based on a study population (STROBE). Qualified personnel conducted a podiatric and dental examination of each child, recording the Clarke angle and the foot posture index (FPI) as an outcomes measure in the feet, and also dental malocclusions, according to Angle classification. A significant correlation was observed for the FPI scores (for right foot) as well as the Clarke angle (for right foot), in relation to dental malocclusions as determined by Angle classification (P < .001). Of all the supinated feet analyzed, 38.46% were Class II according to Angle classification, and none were Class III. Of the pronated feet, 48.57% were Class III, 42.85% were Class I, and 8.57% were Class II. The Clarke angle decreases with the progression from Class I to III, whereas the FPI increases with that from Class I to III. These findings suggest there is a relation between the Clarke angle and FPI, on the one hand, and dental malocclusion on the other. PMID:29742725
Marchena-Rodríguez, Ana; Moreno-Morales, Noelia; Ramírez-Parga, Edith; Labajo-Manzanares, María Teresa; Luque-Suárez, Alejandro; Gijon-Nogueron, Gabriel
2018-05-01
The aim of this study was to determine the association, if any, between foot posture and dental malocclusions in the anteroposterior plane, in children.The study population consisted of 189 children (95 boys and 94 girls) aged 6 to 9 years. In every case, previous informed consent was requested and obtained from the parent/guardian and the study was approved by the Ethics Committee of the University of Málaga (CEUMA 26/2015H).This observational, descriptive, cross-sectional analysis is based on a study population (STROBE). Qualified personnel conducted a podiatric and dental examination of each child, recording the Clarke angle and the foot posture index (FPI) as an outcomes measure in the feet, and also dental malocclusions, according to Angle classification.A significant correlation was observed for the FPI scores (for right foot) as well as the Clarke angle (for right foot), in relation to dental malocclusions as determined by Angle classification (P < .001). Of all the supinated feet analyzed, 38.46% were Class II according to Angle classification, and none were Class III. Of the pronated feet, 48.57% were Class III, 42.85% were Class I, and 8.57% were Class II.The Clarke angle decreases with the progression from Class I to III, whereas the FPI increases with that from Class I to III. These findings suggest there is a relation between the Clarke angle and FPI, on the one hand, and dental malocclusion on the other.
Huang, P-Y; Lin, C-F; Kuo, L-C; Liao, J-C
2011-12-01
This study evaluates foot pressure and center of pressure (COP) patterns in individuals with ankle instability during running and lateral shuffling. Eleven participants with ankle instability (AI) and 11 normal subjects (Normal) performed running and lateral shuffling tasks. The outcome measures were foot progression angle, peak pressure, and displacement of COP during stance phase. During running, the foot progression angle, that is, the angle of foot abduction, was lower in the AI group (Normal: 13.46° ± 4.45°; AI: 8.78° ± 3.91°), and the 1st metatarsal contact pressure (Normal: 0.76 ± 0.47 N/cm(2)·kg; AI: 1.05 ± 0.70 N/cm(2)·kg) and the 3rd metatarsal peak pressure were higher in the AI (Normal: 0.96 ± 0.60 N/cm(2)·kg; AI: 1.54 ± 0.68 N/cm(2)·kg). The medial-lateral (M-L) COP in the late-stance phase of running for the AI group transferred faster from lateral to medial foot than the Normal group. For lateral shuffling, the AI group had greater peak pressure at the 1st (Normal: 0.76 ± 0.67 N/cm(2)·kg; AI: 1.49 ± 1.04 N/cm(2)·kg), 2nd (Normal: 0.57 ± 0.39 N/cm(2)·kg; AI: 0.87 ± 0.68 N/cm(2)·kg), 3rd (Normal: 0.70 ± 0.54 N/cm(2)·kg; AI: 1.42 ± 0.87 N/cm(2)·kg), and 4th (Normal: 0.52 ± 0.38 N/cm(2)·kg; AI: 1.12 ± 0.78 N/cm(2)·kg) metatarsal areas than the Normal group. The M-L COP located more laterally from the early to mid-stance phase in the AI compared with the Normal group. The findings suggest that COP displacement during lateral shuffle may be a factor in ankle instability while the foot progression angle during running may be a compensatory strategy. © 2011 John Wiley & Sons A/S.
Football APP based on smart phone with FES in drop foot rehabilitation.
Ciou, Shih-Hsiang; Hwang, Yuh-Shyan; Chen, Chih-Chen; Luh, Jer-Junn; Chen, Shih-Ching; Chen, Yu-Luen
2017-01-01
Long-term, sustained progress is necessary in drop foot rehabilitation. The necessary inconvenient body training movements, the return trips to the hospital and repetitive boring training using functional electrical stimulation (FES) often results in the patient suspending their training. The patient's drop foot rehabilitation will not progress if training is suspended. A fast spread, highly portable drop foot rehabilitation training device based on the smart phone is presented. This device is combined with a self-made football APP and feedback controlled FES. The drop foot patient can easily engage in long term rehabilitation training that is more convenient and interesting. An interactive game is established on the smart phone with the Android system using the originally built-in wireless communications. The ankle angle information is detected by an external portable device as the game input signal. The electrical stimulation command to the external device is supplemented with FES stimulation for inadequate ankle efforts. After six-weeks training using six cases, the results indicated that this training device showed significant performance improvement (p< 0.05) in the patient's ankle dorsiflexion strength, ankle dorsiflexion angle, control timing and Timed Up and Go. Preliminary results show that this training device provides significant positive help to drop foot patients. Moreover, this device is based on existing and universally popular mobile processing, which can be rapidly promoted. The responses of clinical cases also show this system is easy to operate, convenient and entertaining. All of these features can improve the patient's willingness to engage in long term rehabilitation.
Hunt, M A; Charlton, J M; Krowchuk, N M; Tse, C T F; Hatfield, G L
2018-04-27
To compare changes in knee pain, function, and loading following a 4-month progressive walking program with or without toe-out gait modification in people with medial tibiofemoral knee osteoarthritis. Individuals with medial knee osteoarthritis were randomized to a 4-month program to increase walking activity with (toe-out) or without (progressive walking) concomitant toe-out gait modification. The walking program was similar between the two groups, except that the gait modification group was trained to walk with 15° more toe-out. Primary outcomes included: knee joint pain (WOMAC), foot progression angles and knee joint loading during gait (knee adduction moment (KAM)). Secondary outcomes included WOMAC function, timed stair climb, and knee flexion moments during gait. Seventy-nine participants (40 in toe-out group, 39 in progressive walking group) were recruited. Intention-to-treat analysis showed no between-group differences in knee pain, function, or timed stair climb. However, the toe-out group exhibited significantly greater changes in foot progression angle (mean difference = -9.04° (indicating more toe-out), 95% CI: -11.22°, -6.86°; P < 0.001), late stance KAM (mean difference = -0.26 %BW*ht, 95% CI: -0.39 %BW*ht, -0.12 %BW*ht, P < 0.001) and KAM impulse (-0.06 %BW*ht*s, 95% CI: -0.11 %BW*ht*s, -0.01 %BW*ht*s; P = 0.031) compared to the progressive walking group at follow-up. The only between-group difference that remained at a 1-month retention assessment was foot progression angle, with greater changes in the toe-out group (mean difference = -6.78°, 95% CI: -8.82°, -4.75°; P < 0.001). Though both groups experienced improvements in self-reported pain and function, only the toe-out group experienced biomechanical improvements. NCT02019108. Copyright © 2018 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.
Cho, Byung-Ki; Park, Kyoung-Jin; Choi, Seung-Myung; Im, Se-Hyuk; SooHoo, Nelson F
2017-06-01
This retrospective comparative study reports the practical function in daily and sports activities after tibialis posterior tendon transfer for foot drop secondary to peroneal nerve palsy. Seventeen patients were followed for a minimum of 3 years after tibialis posterior tendon transfer for foot drop secondary to peroneal nerve palsy. Matched controls were used to evaluate the level of functional restoration. Functional evaluations included American Orthopaedic Foot & Ankle Society (AOFAS) scores, Foot and Ankle Outcome Score (FAOS), Foot and Ankle Ability Measure (FAAM) scores, and isokinetic muscle strength test. Radiographic evaluation for the changes of postoperative foot alignment included Meary angle, calcaneal pitch angle, hindfoot alignment angle, and navicular height. Mean AOFAS, FAOS, and FAAM scores significantly improved from 65.1 to 86.2, 55.6 to 87.8, and 45.7 to 84.4 points at final follow-up, respectively. However, all functional evaluation scores were significantly lower as compared to the control group ( P < .001). Mean peak torque (60 degrees/sec) of ankle dorsiflexors, plantarflexors, invertors, and evertors at final follow-up were 7.1 (deficit ratio of 65.4%), 39.2, 9.8, and 7.3 Nm, respectively. These muscle strengths were significantly lower compared to the control group ( P < .001). No significant differences in radiographic measurements were found, and no patients presented with a postoperative flat foot deformity. One patient (5.9%) needed an ankle-foot orthosis for occupational activity. Anterior transfer of the tibialis posterior tendon appears to be an effective surgical option for paralytic foot drop secondary to peroneal nerve palsy. Although restoration of dorsiflexion strength postoperatively was about 33% of the normal ankle, function in daily activities and gait ability were satisfactorily improved. In addition, tibialis posterior tendon transfer demonstrated no definitive radiographic or clinical progression to postoperative flat foot deformity at intermediate-term follow-up. Level IV, retrospective case series.
THE EFFECT OF STEP RATE MANIPULATION ON FOOT STRIKE PATTERN OF LONG DISTANCE RUNNERS.
Allen, Darrell J; Heisler, Hollie; Mooney, Jennifer; Kring, Richard
2016-02-01
Running gait retraining to change foot strike pattern in runners from a heel strike pattern to a non heel- strike pattern has been shown to reduce impact forces and may help to reduce running related injuries. Step rate manipulation above preferred is known to help decrease step length, foot inclination angle, and vertical mass excursion, but has not yet been evaluated as a method to change foot strike pattern. The purpose of this study was to investigate the effect of step rate manipulation on foot strike pattern in shod recreational runners who run with a heel strike pattern. A secondary purpose was to describe the effect of step rate manipulation at specific percentages above preferred on foot inclination angle at initial contact. Forty volunteer runners, who were self-reported heel strikers and had a weekly running mileage of at least 10 miles, were recruited. Runners were confirmed to be heel strikers during the warm up period on the treadmill. The subject's step rate was determined at their preferred running pace. A metronome was used to increase step rate above the preferred step rate by 5%, 10% and 15%. 2D video motion analysis was utilized to determine foot strike pattern and to measure foot inclination angle at initial contact for each step rate condition. There was a statistically significant change in foot strike pattern from a heel strike pattern to a mid-foot or forefoot strike pattern at both 10% and 15% step rates above preferred. Seven of the 40 subjects (17.5%) changed from a heel- strike pattern to a non- heel strike pattern at +10% and 12 of the 40 subjects (30%) changed to a non-heel strike pattern at +15%. Mean foot inclination angle at initial contact showed a statistically significant change (reduction) as step rate increased. Step rate manipulation of 10% or greater may be enough to change foot strike pattern from a heel strike to a mid-foot or forefoot strike pattern in a small percentage of recreational runners who run in traditional running shoes. If changing the foot strike pattern is the main goal, other gait re-training methods may be needed to make a change from a heel strike to a non-heel strike pattern. Step rate manipulation shows a progressive reduction of foot inclination angle at 5%, 10%, and 15% above preferred step rate which reduces the severity of the heel strike at initial contact. Step rate manipulation of at least +10% above preferred may be an effective running gait retraining method for clinicians to decrease the severity of heel strike and possibly assist a runner to change to a non-heel strike pattern. 3.
Inter-segment foot motion in girls using a three-dimensional multi-segment foot model.
Jang, Woo Young; Lee, Dong Yeon; Jung, Hae Woon; Lee, Doo Jae; Yoo, Won Joon; Choi, In Ho
2018-05-06
Several multi-segment foot models (MFMs) have been introduced for in vivo analyses of dynamic foot kinematics. However, the normal gait patterns of healthy children and adolescents remain uncharacterized. We sought to determine normal foot kinematics according to age in clinically normal female children and adolescents using a Foot 3D model. Fifty-eight girls (age 7-17 years) with normal function and without radiographic abnormalities were tested. Three representative strides from five separate trials were analyzed. Kinematic data of foot segment motion were tracked and evaluated using an MFM with a 15-marker set (Foot 3D model). As controls, 50 symptom-free female adults (20-35 years old) were analyzed. In the hindfoot kinematic analysis, plantar flexion motion in the pre-swing phase was significantly greater in girls aged 11 years or older than in girls aged <11 years, thereby resulting in a larger sagittal range of motion. Coronal plane hindfoot motion exhibited pronation, whereas transverse plane hindfoot motion exhibited increased internal rotation in girls aged <11 years. Hallux valgus angles increased significantly in girls aged 11 years or older. The foot progression angle showed mildly increased internal rotation in the loading response phase and the swing phase in girls aged <11 years old. The patterns of inter-segment foot motion in girls aged 11 years or older showed low-arch kinematic characteristics, whereas those in girls aged 11 years or older were more similar to the patterns in young adult women. Copyright © 2018 Elsevier B.V. All rights reserved.
Effect of taping on foot kinematics in persons with chronic ankle instability.
Deschamps, Kevin; Dingenen, Bart; Pans, Femke; Van Bavel, Isabelle; Matricali, Giovanni Arnoldo; Staes, Filip
2016-07-01
To investigate differences in rigid-foot and multi-segmental foot kinematics between healthy (control) and chronic ankle instability (CAI) participants during running and to evaluate the effect of low-Dye (LD) and high-Dye (HD) taping on foot kinematics of CAI subjects. Cross-sectional, comparative study. Kinematic data of 12 controls and 15 CAI participants were collected by a 3D motion analysis system during running. CAI participants performed barefoot (CAI_BF) running trials as well as trials with taping. A rigid Plug-in gait Model and the Rizzoli 3D Multi-Segment Foot Model were used. Groups were compared using one-dimensional statistical parametric mapping. An increased inversion, a decreased dorsiflexion between the foot and tibia and a decreased external foot progression angle were found during terminal swing and early stance in the CAI_BF group. With respect to the taped conditions, post-hoc SPM{t} calculations highlighted a more dorsiflexed rearfoot (38-46% running cycle) in the CAI_HD compared to the CAI_LD, and a more inverted Mid-Met angle (6-24% running cycle) in the CAI_LD compared to the CAI_BF condition. This study revealed significant differences in rigid foot and multi-segmental foot kinematics between all groups. As high-dye taping embraces shank-rearfoot and forefoot, it seems to have better therapeutic features with respect to low-dye taping as the latter created a more inverted forefoot which may not be recommended in this population. Copyright © 2015 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.
2013-01-01
Background In spastic cerebral palsy (SCP), a limited range of motion of the foot (ROM), limits gait and other activities. Assessment of this limitation of ROM and knowledge of active mechanisms is of crucial importance for clinical treatment. Methods For a comparison between spastic cerebral palsy (SCP) children and typically developing children (TD), medial gastrocnemius muscle-tendon complex length was assessed using 3-D ultrasound imaging techniques, while exerting externally standardized moments via a hand-held dynamometer. Exemplary X-ray imaging of ankle and foot was used to confirm possible TD-SCP differences in foot deformation. Results SCP and TD did not differ in normalized level of excitation (EMG) of muscles studied. For given moments exerted in SCP, foot plate angles were all more towards plantar flexion than in TD. However, foot plate angle proved to be an invalid estimator of talocrural joint angle, since at equal foot plate angles, GM muscle-tendon complex was shorter in SCP (corresponding to an equivalent of 1 cm). A substantial difference remained even after normalizing for individual differences in tibia length. X-ray imaging of ankle and foot of one SCP child and two typically developed adults, confirmed that in SCP that of total footplate angle changes (0-4 Nm: 15°), the contribution of foot deformation to changes in foot plate angle (8) were as big as the contribution of dorsal flexion at the talocrural joint (7°). In typically developed individuals there were relatively smaller contributions (10 -11%) by foot deformation to changes in foot plate angle, indicating that the contribution of talocrural angle changes was most important. Using a new estimate for position at the talocrural joint (the difference between GM muscle–tendon complex length and tibia length, GM relative length) removed this effect, thus allowing more fair comparison of SCP and TD data. On the basis of analysis of foot plate angle and GM relative length as a function of externally applied moments, it is concluded that foot plate angle measurements underestimate angular changes at the talocrural joint when moving in dorsal flexion direction and overestimate them when moving in plantar flexion direction, with concomitant effects on triceps surae lengths. Conclusions In SCP children diagnosed with decreased dorsal ROM of the ankle joint, the commonly used measure (i.e. range of foot plate angle), is not a good estimate of rotation at the talocrural joint. since a sizable part of the movement of the foot (or foot plate) derives from internal deformation of the foot. PMID:24364826
Sagittal plane kinematics of passive dorsiflexion of the foot in adolescent athletes.
Gatt, Alfred; Chockalingam, Nachiappan; Falzon, Owen
2013-01-01
Although assessment of passive maximum foot dorsiflexion angle is performed routinely, there is a paucity of information regarding adolescents' foot and foot segment motion during this procedure. There are currently no trials investigating the kinematics of the adolescent foot during passive foot dorsiflexion. A six-camera optoelectronic motion capture system was used to collect kinematic data using the Oxford Foot Model. Eight female amateur gymnasts 11 to 16 years old (mean age, 13.2 years; mean height, 1.5 m) participated in the study. A dorsiflexing force was applied to the forefoot until reaching maximum resistance with the foot placed in the neutral, pronated, and supinated positions in random order. The maximum foot dorsiflexion angle and the range of movement of the forefoot to hindfoot, tibia to forefoot, and tibia to hindfoot angles were computed. Mean ± SD maximum foot dorsiflexion angles were 36.3° ± 7.2° for pronated, 36.9° ± 4.0° for neutral, and 33.0° ± 4.9° for supinated postures. One-way repeated-measures analysis of variance results were nonsignificant among the 3 groups (P = .70), as were the forefoot to tibia angle and hindfoot to tibia angle variations (P = .091 and P = .188, respectively). Forefoot to hindfoot angle increased with the application of force, indicating that in adolescents, the forefoot does not lock at any particular posture as portrayed by the traditional Rootian paradigm. Participants had very flexible foot dorsiflexion, unlike those in another study assessing adolescent athletes. This finding, together with nonsignificant statistical results, implies that foot dorsiflexion measurement may be performed at any foot posture without notably affecting results.
2013-01-01
Background The relationship between torsional bony deformities and rotational gait parameters has not been sufficiently investigated. This study was to investigate the degree of contribution of torsional bony deformities to rotational gait parameters in patients with diplegic cerebral palsy (CP). Methods Thirty three legs from 33 consecutive ambulatory patients (average age 9.5 years, SD 6.9 years; 20 males and 13 females) with diplegic CP who underwent preoperative three dimensional gait analysis, foot radiographs, and computed tomography (CT) were included. Adjusted foot progression angle (FPA) was retrieved from gait analysis by correcting pelvic rotation from conventional FPA, which represented the rotational gait deviation of the lower extremity from the tip of the femoral head to the foot. Correlations between rotational gait parameters (FPA, adjusted FPA, average pelvic rotation, average hip rotation, and average knee rotation) and radiologic measurements (acetabular version, femoral anteversion, knee torsion, tibial torsion, and anteroposteriortalo-first metatarsal angle) were analyzed. Multiple regression analysis was performed to identify significant contributing radiographic measurements to adjusted FPA. Results Adjusted FPA was significantly correlated with FPA (r=0.837, p<0.001), contralateral FPA (r=0.492, p=0.004), pelvic rotation during gait (r=−0.489, p=0.004), knee rotation during gait (r=0.376, p=0.031), and femoral anteversion (r=0.350, p=0.046). In multiple regression analysis, femoral anteversion (p=0.026) and tibial torsion (p=0.034) were found to be the significant contributing structural deformities to the adjusted FPA (R2=0.247). Conclusions Femoral anteversion and tibial torsion were found to be the significant structural deformities that could affect adjusted FPA in patients with diplegic CP. Femoral anteversion and tibial torsion could explain only 24.7% of adjusted FPA. PMID:23767833
Validation of hand and foot anatomical feature measurements from smartphone images
NASA Astrophysics Data System (ADS)
Amini, Mohammad; Vasefi, Fartash; MacKinnon, Nicholas
2018-02-01
A smartphone mobile medical application, previously presented as a tool for individuals with hand arthritis to assess and monitor the progress of their disease, has been modified and expanded to include extraction of anatomical features from the hand (joint/finger width, and angulation) and foot (length, width, big toe angle, and arch height index) from smartphone camera images. Image processing algorithms and automated measurements were validated by performing tests on digital hand models, rigid plastic hand models, and real human hands and feet to determine accuracy and reproducibility compared to conventional measurement tools such as calipers, rulers, and goniometers. The mobile application was able to provide finger joint width measurements with accuracy better than 0.34 (+/-0.25) millimeters. Joint angulation measurement accuracy was better than 0.50 (+/-0.45) degrees. The automatically calculated foot length accuracy was 1.20 (+/-1.27) millimeters and the foot width accuracy was 1.93 (+/-1.92) millimeters. Hallux valgus angle (used in assessing bunions) accuracy was 1.30 (+/-1.29) degrees. Arch height index (AHI) measurements had an accuracy of 0.02 (+/-0.01). Combined with in-app documentation of symptoms, treatment, and lifestyle factors, the anatomical feature measurements can be used by both healthcare professionals and manufacturers. Applications include: diagnosing hand osteoarthritis; providing custom finger splint measurements; providing compression glove measurements for burn and lymphedema patients; determining foot dimensions for custom shoe sizing, insoles, orthotics, or foot splints; and assessing arch height index and bunion treatment effectiveness.
Cimelli, Sonja N; Curran, Sarah A
2012-01-01
The angle of turnout is thought to predispose professional dancers to overuse musculoskeletal injuries of the lower limb; yet, the influence of angle of turnout on foot posture is currently unknown. Twelve professional contemporary dancers (five women and seven men; mean age, 26.8 years) were recruited. The angle of gait and angle of turnout were measured using a quasi-static clinical tracing method. Foot posture was assessed in the base of gait and angle of turnout using the Foot Posture Index. Each dancer completed a dance history and injury questionnaire. The results show a tendency toward a pronated foot posture (mean, 9°) in the angle of turnout position. A significant relationship was noted between the Foot Posture Index and angle of turnout (ρ = 0.933-0.968, P < .01) and between the number of reported injuries and change in foot posture in the angle of turnout (ρ = 0.789, P < .01) (right foot only). Twenty-eight injuries were reported; male dancers experienced a mean of 2.8 injuries and females a mean of 1.6 injuries. An inverse relationship was noted between age at training initiation and total reported injuries (r =-0.867, P < .01). All of the dancers reported a history of injury to the spine or lower limb, and 9 of the 12 reported an injury within the previous 12 months. Turnout is one of the most fundamental aspects of dance technique. This study suggests a trend toward pronation in angle of turnout and a link to lower-limb musculoskeletal injury.
Measurement of first ray of foot with reference to hallux valgus.
Howale, Deepak S; Iyer, Kanaklata V; Shah, Jigesh V
2012-06-01
A study was carried out on 58 healthy volunteers. None of the volunteeres had any foot complaints. This was done to study Indian feet, as foot is an important part of human anatomy and its certain deformities eg, hallux valgus, can be very disabling. We have studied anatomical angles between 1st and 2nd rays of foot eg, angle of hallux valgus and angle of slant of distal facet of medial cuneiform and have shown significant correlation between them and development of hallux valgus. The coefficient of correlation (r) calculated between these two angles is significant, showing that this angle influences the angle of hallux valgus and hence development of hallux valgus. These are anatomical angles and indicate shapes of medial cuneiform and 1st metatarsal. Hence these seem to be inherited, making the feet anatomically predisposed to develop hallux valgus. This view is supported by Gray's Anatomy. The extrinsic factors such as narrow toes, closed, footwear worn for an extended period do increase the angle of hallux valgus. So, in predisposed feet, this is one of the extrinsic factor which can lead to development of hallux valgus. On studying these two angles, orthopaedicians should be on alert and should advise such individuals on wearing foot- friendly foot-wear.
Lee, Dong Yeon; Seo, Sang Gyo; Kim, Eo Jin; Kim, Sung Ju; Lee, Kyoung Min; Farber, Daniel C; Chung, Chin Youb; Choi, In Ho
2015-01-01
Radiographic examination is a widely used evaluation method in the orthopedic clinic. However, conventional radiography alone does not reflect the dynamic changes between foot and ankle segments during gait. Multiple 3-dimensional multisegment foot models (3D MFMs) have been introduced to evaluate intersegmental motion of the foot. In this study, we evaluated the correlation between static radiographic indices and intersegmental foot motion indices. One hundred twenty-five females were tested. Static radiographs of full-leg and anteroposterior (AP) and lateral foot views were performed. For hindfoot evaluation, we measured the AP tibiotalar angle (TiTA), talar tilt (TT), calcaneal pitch, lateral tibiocalcaneal angle, and lateral talcocalcaneal angle. For the midfoot segment, naviculocuboid overlap and talonavicular coverage angle were calculated. AP and lateral talo-first metatarsal angles and metatarsal stacking angle (MSA) were measured to assess the forefoot. Hallux valgus angle (HVA) and hallux interphalangeal angle were measured. In gait analysis by 3D MFM, intersegmental angle (ISA) measurements of each segment (hallux, forefoot, hindfoot, arch) were recorded. ISAs at midstance phase were most highly correlated with radiography. Significant correlations were observed between ISA measurements using MFM and static radiographic measurements in the same segment. In the hindfoot, coronal plane ISA was correlated with AP TiTA (P < .001) and TT (P = .018). In the hallux, HVA was strongly correlated with transverse ISA of the hallux (P < .001). The segmental foot motion indices at midstance phase during gait measured by 3D MFM gait analysis were correlated with the conventional radiographic indices. The observed correlation between MFM measurements at midstance phase during gait and static radiographic measurements supports the fundamental basis for the use of MFM in analysis of dynamic motion of foot segment during gait. © The Author(s) 2014.
OPTOTRAK Measurement of the Quadriceps Angle Using Standardized Foot Positions
Livingston, Lori A.; Spaulding, Sandi J.
2002-01-01
Objective: While there is evidence to suggest that the magnitude of the quadriceps (Q) angle changes with alterations in foot position, a detailed quantitative description of this relationship has not been reported. Our purpose was to determine the effect of varying foot placement on the magnitude of the Q angle. Design and Setting: A mixed between-within, repeated-measures design was used to compare Q angles derived under static weight-bearing conditions with the feet positioned in self-selected versus standardized stance positions. Subjects: Twenty healthy young-adult men and women with no history of acute injury to or chronic dysfunction of the lower limbs. Measurements: We placed light-emitting diodes bilaterally on the left and right anterior superior iliac spines, the tibial tuberosities, and the midpoints of the patellae to bilaterally define the Q angles. An OPTOTRAK motion-measurement system was used to capture x,y coordinate data at a sampling rate of 60 Hz. These data were subsequently filtered and used to calculate the magnitude of the left and right Q angles. Results: A repeated-measures analysis of variance revealed that when measured statically, Q angles differed significantly between stance positions (P < .001) and limbs (P < .05). Depending on the stance adopted, mean Q angles varied from 7.2° to 12.7° and 11.0° to 16.1° in the left and right lower limbs, respectively. Q-angle measurements taken in conjunction with the Romberg foot position most closely resembled those gathered with the feet in a self-selected stance (Pearson r = 0.86 to 0.92). Conclusions: Q-angle magnitude varies with changes in foot position, increasing or decreasing as the foot rotates internally or externally, respectively. These data demonstrate the need for a standardized foot position for Q-angle measurements. PMID:12937581
OPTOTRAK Measurement of the Quadriceps Angle Using Standardized Foot Positions.
Livingston, Lori A; Spaulding, Sandi J
2002-09-01
OBJECTIVE: While there is evidence to suggest that the magnitude of the quadriceps (Q) angle changes with alterations in foot position, a detailed quantitative description of this relationship has not been reported. Our purpose was to determine the effect of varying foot placement on the magnitude of the Q angle. DESIGN AND SETTING: A mixed between-within, repeated-measures design was used to compare Q angles derived under static weight-bearing conditions with the feet positioned in self-selected versus standardized stance positions. SUBJECTS: Twenty healthy young-adult men and women with no history of acute injury to or chronic dysfunction of the lower limbs. MEASUREMENTS: We placed light-emitting diodes bilaterally on the left and right anterior superior iliac spines, the tibial tuberosities, and the midpoints of the patellae to bilaterally define the Q angles. An OPTOTRAK motion-measurement system was used to capture x,y coordinate data at a sampling rate of 60 Hz. These data were subsequently filtered and used to calculate the magnitude of the left and right Q angles. RESULTS: A repeated-measures analysis of variance revealed that when measured statically, Q angles differed significantly between stance positions (P <.001) and limbs (P <.05). Depending on the stance adopted, mean Q angles varied from 7.2 degrees to 12.7 degrees and 11.0 degrees to 16.1 degrees in the left and right lower limbs, respectively. Q-angle measurements taken in conjunction with the Romberg foot position most closely resembled those gathered with the feet in a self-selected stance (Pearson r = 0.86 to 0.92). CONCLUSIONS: Q-angle magnitude varies with changes in foot position, increasing or decreasing as the foot rotates internally or externally, respectively. These data demonstrate the need for a standardized foot position for Q-angle measurements.
Park, Jaeyong; Lee, Sang Gil; Bae, Jongjin; Lee, Jung Chul
2015-12-01
[Purpose] This study aimed to provide a predictable evaluation method for the progression of scoliosis in adolescents based on quick and reliable measurements using the naked eye, such as the calcaneal valgus angle of the foot, which can be performed at public facilities such as schools. [Subjects and Methods] Idiopathic scoliosis patients with a Cobb's angle of 10° or more (96 females, 22 males) were included in this study. To identify relationships between factors, Pearson's product-moment correlation coefficient was computed. The degree of scoliosis was set as a dependent variable to predict thoracic and lumbar scoliosis using ankle angle and physique factors. Height, weight, and left and right calcaneal valgus angles were set as independent variables; thereafter, multiple regression analysis was performed. This study extracted variables at a significance level (α) of 0.05 by applying a stepwise method, and calculated a regression equation. [Results] Negative correlation (R=-0.266) was shown between lumbar lordosis and asymmetrical lumbar rotation angles. A correlation (R=0.281) was also demonstrated between left calcaneal valgus angles and asymmetrical thoracic rotation angles. [Conclusion] Prediction of scoliosis progress was revealed to be possible through ocular inspection of the calcaneus and Adams forward bending test and the use of a scoliometer.
Balsdon, Megan E R; Bushey, Kristen M; Dombroski, Colin E; LeBel, Marie-Eve; Jenkyn, Thomas R
2016-10-01
The structure of the medial longitudinal arch (MLA) affects the foot's overall function and its ability to dissipate plantar pressure forces. Previous research on the MLA includes measuring the calcaneal-first metatarsal angle using a static sagittal plane radiograph, a dynamic height-to-length ratio using marker clusters with a multisegment foot model, and a contained angle using single point markers with a multisegment foot model. The objective of this study was to use biplane fluoroscopy to measure a contained MLA angle between foot types: pes planus (low arch), pes cavus (high arch), and normal arch. Fifteen participants completed the study, five from each foot type. Markerless fluoroscopic radiostereometric analysis (fRSA) was used with a three-dimensional model of the foot bones and manually matching those bones to a pair of two-dimensional radiographic images during midstance of gait. Statistically significant differences were found between barefoot arch angles of the normal and pes cavus foot types (p = 0.036), as well as between the pes cavus and pes planus foot types (p = 0.004). Dynamic walking also resulted in a statistically significant finding compared to the static standing trials (p = 0.014). These results support the classification of individuals following a physical assessment by a foot specialist for those with pes cavus and planus foot types. The differences between static and dynamic kinematic measurements were also supported using this novel method.
Lopezosa-Reca, Eva; Gijon-Nogueron, Gabriel; Garcia-Paya, Irene; Ortega-Avila, Ana Belen
2018-03-04
This aim of this study is to observe the differences in foot posture and the angle of the knee according to different physical activities. Seventy-eight football players and 72 swimmers were recruited, and in each case a foot posture analysis, based on the foot posture index (FPI), was conducted and the Q angle of the knee was determined. The following mean values were obtained for the lower extremities: in the swimmers, FPI 6.45 ± 2.04 and Q angle 15.38º ± 3.79º. In the footballers, FPI 2.23 ± 1.72 and Q angle 13.16º ± 1.36º. There were statistically significant differences (p < 0.001) between the two groups. The swimmers presented a foot posture with a tendency towards pronation, and a Q angle with a tendency towards valgus, while the results for the footballers were within the normal range.
Buldt, Andrew K; Levinger, Pazit; Murley, George S; Menz, Hylton B; Nester, Christopher J; Landorf, Karl B
2015-06-01
Variations in foot posture are associated with the development of some lower limb injuries. However, the mechanisms underlying this relationship are unclear. The objective of this study was to compare foot kinematics between normal, pes cavus and pes planus foot posture groups using a multi-segment foot model. Ninety-seven healthy adults, aged 18-47 were classified as either normal (n=37), pes cavus (n=30) or pes planus (n=30) based on normative data for the Foot Posture Index, Arch Index and normalised navicular height. A five segment foot model was used to measure tri-planar motion of the rearfoot, midfoot, medial forefoot, lateral forefoot and hallux during barefoot walking at a self-selected speed. Angle at heel contact, peak angle, time to peak angle and range of motion was measured for each segment. One way ANOVAs with post-hoc analyses of mean differences were used to compare foot posture groups. The pes cavus group demonstrated a distinctive pattern of motion compared to the normal and pes planus foot posture groups. Effect sizes of significant mean differences were large and comparable to similar studies. Three key differences in overall foot function were observed between the groups: (i) altered frontal and transverse plane angles of the rearfoot in the pes cavus foot; (ii) Less midfoot motion in the pes cavus foot during initial contact and midstance; and (iii) reduced midfoot frontal plane ROM in the pes planus foot during pre-swing. These findings indicate that foot posture does influence motion of the foot. Copyright © 2015 Elsevier B.V. All rights reserved.
Khan, Saad Jawaid; Khan, Soobia Saad; Usman, Juliana; Mokhtar, Abdul Halim; Abu Osman, Noor Azuan
2018-02-01
This study aims to investigate the effects of varying toe angles at different platform settings on Overall Stability Index of postural stability and fall risk using Biodex Balance System in healthy participants and medial knee osteoarthritis patients. Biodex Balance System was employed to measure postural stability and fall risk at different foot progression angles (ranging from -20° to 40°, with 10° increments) on 20 healthy (control group) and 20 knee osteoarthritis patients (osteoarthritis group) randomly (age: 59.50 ± 7.33 years and 61.50 ± 8.63 years; body mass: 69.95 ± 9.86 kg and 70.45 ± 8.80 kg). Platform settings used were (1) static, (2) postural stability dynamic level 8 (PS8), (3) fall risk levels 12 to 8 (FR12) and (4) fall risk levels 8 to 2 (FR8). Data from the tests were analysed using three-way mixed repeated measures analysis of variance. The participant group, platform settings and toe angles all had a significant main effect on balance ( p ≤ 0.02). Platform settings had a significant interaction effect with participant group F(3, 144) = 6.97, p < 0.01 and toe angles F(21, 798) = 2.83, p < 0.01. Non-significant interactions were found for group × toe angles, F(7, 266) = 0.89, p = 0.50, and for group × toe angles × settings, F(21, 798) = 1.07, p = 0.36. The medial knee osteoarthritis group has a poorer postural stability and increased fall risk as compared to the healthy group. Changing platform settings has a more pronounced effect on balance in knee osteoarthritis group than in healthy participants. Changing toe angles produced similar effects in both the participant groups, with decreased stability and increased fall risk at extreme toe-in and toe-out angles.
Descriptive Quantitative Analysis of Rearfoot Alignment Radiographic Parameters.
Meyr, Andrew J; Wagoner, Matthew R
2015-01-01
Although the radiographic parameters of the transverse talocalcaneal angle (tTCA), calcaneocuboid angle (CCA), talar head uncovering (THU), calcaneal inclination angle (CIA), talar declination angle (TDA), lateral talar-first metatarsal angle (lTFA), and lateral talocalcaneal angle (lTCA) form the basis of the preoperative evaluation and procedure selection for pes planovalgus deformity, the so-called normal values of these measurements are not well-established. The objectives of the present study were to retrospectively evaluate the descriptive statistics of these radiographic parameters (tTCA, CCA, THU, CIA, TDA, lTFA, and lTCA) in a large population, and, second, to determine an objective basis for defining "normal" versus "abnormal" measurements. As a secondary outcome, the relationship of these variables to the body mass index was assessed. Anteroposterior and lateral foot radiographs from 250 consecutive patients without a history of previous foot and ankle surgery and/or trauma were evaluated. The results revealed a mean measurement of 24.12°, 13.20°, 74.32%, 16.41°, 26.64°, 8.37°, and 43.41° for the tTCA, CCA, THU, CIA, TDA, lTFA, and lTCA, respectively. These were generally in line with the reported historical normal values. Descriptive statistical analysis demonstrated that the tTCA, THU, and TDA met the standards to be considered normally distributed but that the CCA, CIA, lTFA, and lTCA demonstrated data characteristics of both parametric and nonparametric distributions. Furthermore, only the CIA (R = -0.2428) and lTCA (R = -0.2449) demonstrated substantial correlation with the body mass index. No differentiations in deformity progression were observed when the radiographic parameters were plotted against each other to lead to a quantitative basis for defining "normal" versus "abnormal" measurements. Copyright © 2015 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.
Effect of foot shape on the three-dimensional position of foot bones.
Ledoux, William R; Rohr, Eric S; Ching, Randal P; Sangeorzan, Bruce J
2006-12-01
To eliminate some of the ambiguity in describing foot shape, we developed three-dimensional (3D), objective measures of foot type based on computerized tomography (CT) scans. Feet were classified via clinical examination as pes cavus (high arch), neutrally aligned (normal arch), asymptomatic pes planus (flat arch with no pain), or symptomatic pes planus (flat arch with pain). We enrolled 10 subjects of each foot type; if both feet were of the same foot type, then each foot was scanned (n=65 total). Partial weightbearing (20% body weight) CT scans were performed. We generated embedded coordinate systems for each foot bone by assuming uniform density and calculating the inertial matrix. Cardan angles were used to describe five bone-to-bone relationships, resulting in 15 angular measurements. Significant differences were found among foot types for 12 of the angles. The angles were also used to develop a classification tree analysis, which determined the correct foot type for 64 of the 65 feet. Our measure provides insight into how foot bone architecture differs between foot types. The classification tree analysis demonstrated that objective measures can be used to discriminate between feet with high, normal, and low arches. Copyright (c) 2006 Orthopaedic Research Society.
Harmful cleats of football boots: a biomechanical evaluation.
Bentley, J A; Ramanathan, A K; Arnold, G P; Wang, W; Abboud, R J
2011-09-01
Football players wear boots of varying cleat designs with some preferring the bladed cleats while others opting for the conventional studded cleats. The current study compares biomechanically the boots with differing cleat designs and their effect on feet, if any. Twenty-nine healthy male volunteers were recruited from amateur football teams. They were asked to perform three trials each of two activities: a straight run and a run cutting at a 60° angle wearing bladed and studded Adidas®-F series boots on artificial turf. Plantar pressure values were recorded using the Pedar®-X in-shoe pressure measuring device. Peak pressure and pressure-time integral were analysed over 11 clinically relevant areas under the foot. While the in-shoe pressure and pressure-time integral were higher under the medial half of the foot with studded boots, they were higher under the lateral half of the foot with the bladed design. The studded boots can be considered safer as the pressure distribution across the foot and the pattern of centre of pressure progression mimicked the normal motif, whereas the bladed boots could potentially be deemed relatively more harmful due to the unnatural increased loading under the lateral half of the foot, predisposing the foot to injuries. Copyright © 2010 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.
Variability between Clarke's angle and Chippaux-Smirak index for the diagnosis of flat feet
Gonzalez-Martin, Cristina; Seoane-Pillado, Teresa; Lopez-Calviño, Beatriz; Pertega-Diaz, Sonia; Gil-Guillen, Vicente
2017-01-01
Abstract Background: The measurements used in diagnosing biomechanical pathologies vary greatly. The aim of this study was to determine the concordance between Clarke's angle and Chippaux-Smirak index, and to determine the validity of Clarke's angle using the Chippaux-Smirak index as a reference. Methods: Observational study in a random population sample (n= 1,002) in A Coruña (Spain). After informed patient consent and ethical review approval, a study was conducted of anthropometric variables, Charlson comorbidity score, and podiatric examination (Clarke's angle and Chippaux-Smirak index). Descriptive analysis and multivariate logistic regression were performed. Results: The prevalence of flat feet, using a podoscope, was 19.0% for the left foot and 18.9% for the right foot, increasing with age. The prevalence of flat feet according to the Chippaux-Smirak index or Clarke's angle increases significantly, reaching 62.0% and 29.7% respectively. The concordance (kappa I) between the indices according to age groups varied between 0.25-0.33 (left foot) and 0.21-0.30 (right foot). The intraclass correlation coefficient (ICC) between the Chippaux-Smirak index and Clarke's angle was -0.445 (left foot) and -0.424 (right foot). After adjusting for age, body mass index (BMI), comorbidity score and gender, the only variable with an independent effect to predict discordance was the BMI (OR= 0.969; 95% CI: 0.940-0.998). Conclusion: There is little concordance between the indices studied for the purpose of diagnosing foot arch pathologies. In turn, Clarke's angle has a limited sensitivity in diagnosing flat feet, using the Chippaux-Smirak index as a reference. This discordance decreases with higher BMI values. PMID:28559643
Variability between Clarke's angle and Chippaux-Smirak index for the diagnosis of flat feet.
Gonzalez-Martin, Cristina; Pita-Fernandez, Salvador; Seoane-Pillado, Teresa; Lopez-Calviño, Beatriz; Pertega-Diaz, Sonia; Gil-Guillen, Vicente
2017-03-30
The measurements used in diagnosing biomechanical pathologies vary greatly. The aim of this study was to determine the concordance between Clarke's angle and Chippaux-Smirak index, and to determine the validity of Clarke's angle using the Chippaux-Smirak index as a reference. Observational study in a random population sample (n= 1,002) in A Coruña (Spain). After informed patient consent and ethical review approval, a study was conducted of anthropometric variables, Charlson comorbidity score, and podiatric examination (Clarke's angle and Chippaux-Smirak index). Descriptive analysis and multivariate logistic regression were performed. The prevalence of flat feet, using a podoscope, was 19.0% for the left foot and 18.9% for the right foot, increasing with age. The prevalence of flat feet according to the Chippaux-Smirak index or Clarke's angle increases significantly, reaching 62.0% and 29.7% respectively. The concordance (kappa I) between the indices according to age groups varied between 0.25-0.33 (left foot) and 0.21-0.30 (right foot). The intraclass correlation coefficient (ICC) between the Chippaux-Smirak index and Clarke's angle was -0.445 (left foot) and -0.424 (right foot). After adjusting for age, body mass index (BMI), comorbidity score and gender, the only variable with an independent effect to predict discordance was the BMI (OR= 0.969; 95% CI: 0.940-0.998). There is little concordance between the indices studied for the purpose of diagnosing foot arch pathologies. In turn, Clarke's angle has a limited sensitivity in diagnosing flat feet, using the Chippaux-Smirak index as a reference. This discordance decreases with higher BMI values.
The free moment is associated with torsion between the pelvis and the foot during gait.
Ohkawa, Takahiro; Atomi, Tomoaki; Hasegawa, Katsuya; Atomi, Yoriko
2017-10-01
During walking, the friction between the foot and the ground surface causes a free moment (FM), which influences the torsional stress on the lower extremity. However, few studies have investigated the FM during natural walking. The main aim of this study was to examine the relationship between the FM and the absolute and relative rotation angles of the foot and pelvis. The rotation angles of foot and pelvic were measured in 18 healthy men using a motion capture system. Rotation angles were measured in absolute and relative coordinates as well as in reference to the line connecting the center of pressure (CoP) line under the right and left feet to evaluate the effects of the opposite lower limb on the FM. The absolute and relative rotation angles of the foot and pelvis were entered into forced-entry linear regression models to evaluate the influence on the FM. Only the relative angle of rotation between the foot and pelvis could explain the prediction equations significantly. In the Pearson's product-moment correlation coefficient, the rotation angles of the foot and pelvis defined using the bilateral CoP points had not significantly correlated with FM. No joint rotation movement was correlated with FM. The torsion of the entire lower extremity should be performed principally through hip internal rotation. When evaluating the FM as a torsional stress, focusing on the rotation of the entire lower extremity, rather than on one segment, is beneficial. Copyright © 2017 Elsevier B.V. All rights reserved.
Descriptive quantitative analysis of hallux abductovalgus transverse plane radiographic parameters.
Meyr, Andrew J; Myers, Adam; Pontious, Jane
2014-01-01
Although the transverse plane radiographic parameters of the first intermetatarsal angle (IMA), hallux abductus angle (HAA), and the metatarsal-sesamoid position (MSP) form the basis of preoperative procedure selection and postoperative surgical evaluation of the hallux abductovalgus deformity, the so-called normal values of these measurements have not been well established. The objectives of the present study were to (1) evaluate the descriptive statistics of the first IMA, HAA, and MSP from a large patient population and (2) to determine an objective basis for defining "normal" versus "abnormal" measurements. Anteroposterior foot radiographs from 373 consecutive patients without a history of previous foot and ankle surgery and/or trauma were evaluated for the measurements of the first IMA, HAA, and MSP. The results revealed a mean measurement of 9.93°, 17.59°, and position 3.63 for the first IMA, HAA, and MSP, respectively. An advanced descriptive analysis demonstrated data characteristics of both parametric and nonparametric distributions. Furthermore, clear differentiations in deformity progression were appreciated when the variables were graphically depicted against each other. This could represent a quantitative basis for defining "normal" versus "abnormal" values. From the results of the present study, we have concluded that these radiographic parameters can be more conservatively reported and analyzed using nonparametric descriptive and comparative statistics within medical studies and that the combination of a first IMA, HAA, and MSP at or greater than approximately 10°, 18°, and position 4, respectively, appears to be an objective "tipping point" in terms of deformity progression and might represent an upper limit of acceptable in terms of surgical deformity correction. Copyright © 2014 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.
Hafiz, Eliza; Hiller, Claire E; Nicholson, Leslie L; Nightingale, Elizabeth J; Grimaldi, Alison; Refshauge, Kathryn M
2016-03-01
Low range femoral torsion, termed "lateral shaft torsion," has been associated with greater range of hip external rotation and turnout in dancers. It is also hypothesized that achieving greater turnout at the hip minimizes torsion at the knee, shank, ankle, and foot, and consequently reduces incidence of lower limb injuries. The primary aims of this study were to investigate: 1. differences in range of femoral shaft torsion between dancers with and without lower limb injuries; and 2. the relationship between femoral shaft torsion, hip external rotation range, and turnout. A secondary aim was to examine the relationship between femoral shaft torsion and other hip measures: hip strength, lower limb joint hypermobility, hip stability, and foot progression angle, as explanatory variables. Demographic, dance, and injury data were collected, along with physical measures of femoral shaft torsion, hip rotation range of motion, and turnout. Hip strength, control, lower limb hypermobility, and foot progression angle were also measured. Eighty female dancers, 50 with lower limb injury (20.7 ± 4.8 years of age) and 30 without lower limb injury (17.8 ± 4.1 years of age), participated in the study. There was no difference in range of femoral shaft torsion between the groups (p = 0.941). Femoral shaft torsion was weakly correlated with range of hip external rotation (r = -0.034, p = 0.384) and turnout (r = -0.066, p = 0.558). Injured dancers had a significantly longer training history than non-injured dancers (p = 0.001). It was concluded that femoral shaft torsion does not appear to be associated with the overall incidence of lower limb injury in dancers or to be a primary factor influencing extent of turnout in this population.
Radtka, Sandra; Zayac, Jacqueline; Goldberg, Krystyna; Long, Michael; Ixanov, Rustem
2017-03-01
This study determined test-retest reliability of trunk and pelvis joint angles, arm distance and center of pressure (COP) excursion for the seated functional reach test (FRT) and compared these variables during the seated FRT with and without foot support. Fifteen typically developing children (age 9.3±4.1years) participated. Trunk and pelvis joint angles, arm distance, and COP excursion were collected on two days using three-dimensional motion analysis and a force plate while subjects reached maximally with and without foot support in the anterior, anterior/lateral, lateral, posterior/lateral directions. Age, weight, height, trunk and arm lengths were correlated (p<0.01) with maximum arm distance reached. Maximum arm distance, trunk and pelvis joint angles, and COP with and without foot support were not significant (p<0.05) for the two test periods. Excellent reliability (ICCs>0.75) was found for maximum arm distance reached in all four directions in the seated FRT with and without foot support. Most trunk and pelvis joint angles and COP excursions during maximum reach in all four directions showed excellent to fair reliability (ICCs>0.40-0.75). Reaching with foot support in all directions was significantly greater (p<0.05) than without foot support; however, most COP excursions and trunk and pelvic angles were not significantly different. Findings support the addition of anterior/lateral and posterior/lateral reaching directions in the seated FRT. Trunk and pelvis movement analysis is important to examine in the seated FRT to determine the specific movement strategies needed for maximum reaching without loss of balance. Copyright © 2017 Elsevier B.V. All rights reserved.
46 CFR 172.090 - Intact transverse stability.
Code of Federal Regulations, 2014 CFR
2014-10-01
... righting arm curve must be at least 5 foot-degrees (1.52 meter-degrees) up to the smallest of the following... least 10 foot-degrees (3.05 meter-degrees) up to the smallest of the following angles: (i) The angle of... service, the area under the righting arm curve must be at least 15 foot-degrees (4.57 meter-degrees) up to...
46 CFR 172.090 - Intact transverse stability.
Code of Federal Regulations, 2012 CFR
2012-10-01
... righting arm curve must be at least 5 foot-degrees (1.52 meter-degrees) up to the smallest of the following... least 10 foot-degrees (3.05 meter-degrees) up to the smallest of the following angles: (i) The angle of... service, the area under the righting arm curve must be at least 15 foot-degrees (4.57 meter-degrees) up to...
46 CFR 172.090 - Intact transverse stability.
Code of Federal Regulations, 2011 CFR
2011-10-01
... righting arm curve must be at least 5 foot-degrees (1.52 meter-degrees) up to the smallest of the following... least 10 foot-degrees (3.05 meter-degrees) up to the smallest of the following angles: (i) The angle of... service, the area under the righting arm curve must be at least 15 foot-degrees (4.57 meter-degrees) up to...
46 CFR 172.090 - Intact transverse stability.
Code of Federal Regulations, 2013 CFR
2013-10-01
... righting arm curve must be at least 5 foot-degrees (1.52 meter-degrees) up to the smallest of the following... least 10 foot-degrees (3.05 meter-degrees) up to the smallest of the following angles: (i) The angle of... service, the area under the righting arm curve must be at least 15 foot-degrees (4.57 meter-degrees) up to...
46 CFR 172.090 - Intact transverse stability.
Code of Federal Regulations, 2010 CFR
2010-10-01
... righting arm curve must be at least 5 foot-degrees (1.52 meter-degrees) up to the smallest of the following... least 10 foot-degrees (3.05 meter-degrees) up to the smallest of the following angles: (i) The angle of... service, the area under the righting arm curve must be at least 15 foot-degrees (4.57 meter-degrees) up to...
Kobayashi, Toshiki; Singer, Madeline L.; Orendurff, Michael S.; Gao, Fan; Daly, Wayne K.; Foreman, K. Bo
2015-01-01
Background The adjustment of plantarflexion resistive moment of an articulated ankle-foot orthosis is considered important in patients post stroke, but the evidence is still limited. Therefore, the aim of this study was to investigate the effect of changing the plantarflexion resistive moment of an articulated ankle-foot orthosis on ankle and knee joint angles and moments in patients post stroke. Methods Gait analysis was performed on 10 subjects post stroke under four different plantarflexion resistive moment conditions using a newly designed articulated ankle-foot orthosis. Data were recorded using a Bertec split-belt instrumented treadmill in a 3-dimensional motion analysis laboratory. Findings The ankle and knee sagittal joint angles and moments were significantly affected by the amount of plantarflexion resistive moment of the ankle-foot orthosis. Increasing the plantarflexion resistive moment of the ankle-foot orthosis induced significant decreases both in the peak ankle plantarflexion angle (P<0.01) and the peak knee extension angle (P<0.05). Also, the increase induced significant increases in the internal dorsiflexion moment of the ankle joint (P<0.01) and significantly decreased the internal flexion moment of the knee joint (P<0.01). Interpretation These results suggest an important link between the kinematic/kinetic parameters of the lower-limb joints and the plantarflexion resistive moment of an articulated ankle-foot orthosis. A future study should be performed to clarify their relationship further so that the practitioners may be able to use these parameters as objective data to determine an optimal plantarflexion resistive moment of an articulated ankle-foot orthosis for improved orthotic care in individual patients. PMID:26149007
Kobayashi, Toshiki; Singer, Madeline L; Orendurff, Michael S; Gao, Fan; Daly, Wayne K; Foreman, K Bo
2015-10-01
The adjustment of plantarflexion resistive moment of an articulated ankle-foot orthosis is considered important in patients post stroke, but the evidence is still limited. Therefore, the aim of this study was to investigate the effect of changing the plantarflexion resistive moment of an articulated ankle-foot orthosis on ankle and knee joint angles and moments in patients post stroke. Gait analysis was performed on 10 subjects post stroke under four different plantarflexion resistive moment conditions using a newly designed articulated ankle-foot orthosis. Data were recorded using a Bertec split-belt instrumented treadmill in a 3-dimensional motion analysis laboratory. The ankle and knee sagittal joint angles and moments were significantly affected by the amount of plantarflexion resistive moment of the ankle-foot orthosis. Increasing the plantarflexion resistive moment of the ankle-foot orthosis induced significant decreases both in the peak ankle plantarflexion angle (P<0.01) and the peak knee extension angle (P<0.05). Also, the increase induced significant increases in the internal dorsiflexion moment of the ankle joint (P<0.01) and significantly decreased the internal flexion moment of the knee joint (P<0.01). These results suggest an important link between the kinematic/kinetic parameters of the lower-limb joints and the plantarflexion resistive moment of an articulated ankle-foot orthosis. A future study should be performed to clarify their relationship further so that the practitioners may be able to use these parameters as objective data to determine an optimal plantarflexion resistive moment of an articulated ankle-foot orthosis for improved orthotic care in individual patients. Copyright © 2015 Elsevier Ltd. All rights reserved.
Iwanuma, Soichiro; Akagi, Ryota; Hashizume, Satoru; Kanehisa, Hiroaki; Yanai, Toshimasa; Kawakami, Yasuo
2011-09-23
The purpose of this study was to clarify how foot deformation affects the relationship between triceps surae muscle-tendon unit (MTU) length and ankle joint angle. For six women and six men a series of sagittal magnetic resonance (MR) images of the right foot were taken, and changes in MTU length (the displacement of the calcaneal tuberosity), foot arch angle, and ankle joint angle were measured. In the passive session, each subject's ankle joint was secured at 10° dorsiflexed position, neutral position (NP), and 10° and 20° plantar flexed positions while MR images were acquired. In the active session, each subject was requested to perform submaximal isometric plantar flexions (30%, 60%, and 80% of voluntary maximum) at NP. The changes in MTU length in each trial were estimated by two different formulae reported previously. The changes of the measured MTU length as a function of ankle joint angles observed in all trials of the active session were significantly (p<0.05) larger than corresponding values in the passive session and by the estimation formulae. In the passive session, MTU length changes were significantly smaller than the estimated values when the ankle was plantar flexed. The foot arch angle increased as the contraction level increased from rest (117 ± 4°) to 80% (125 ± 3°), and decreased as the ankle was positioned further into plantar flexion in the passive session (115 ± 3°). These results indicate that foot deformation profoundly affects the triceps surae MTU length-ankle joint angle relationship during plantar flexion. Copyright © 2011 Elsevier Ltd. All rights reserved.
Monaghan, Gail M; Hsu, Wen-Hao; Lewis, Cara L; Saltzman, Elliot; Hamill, Joseph; Holt, Kenneth G
2014-09-01
Clinically, foot structures are assessed intrinsically - relation of forefoot to rearfoot and rearfoot to leg. We have argued that, from a biomechanical perspective, the interaction of the foot with the ground may influence forces and torques that are propagated through the lower extremity. We proposed that a more appropriate measure is an extrinsic one that may predict the angle the foot makes with ground at contact. The purposes of this study were to determine if the proposed measure predicts contact angles of the forefoot and rearfoot and assess if the magnitude of those angles influences amplitude and duration of foot eversion during running. With the individual in prone, extrinsic clinical forefoot and rearfoot angles were measured relative to the caudal edge of the examination table. Participants ran over ground while frontal plane forefoot and rearfoot contact angles, forefoot and rearfoot eversion amplitude and duration were measured. Participants were grouped twice, once based on forefoot contact inversion angle (moderate
Gender differences in foot shape: a study of Chinese young adults.
Hong, Youlian; Wang, Lin; Xu, Dong Qing; Li, Jing Xian
2011-06-01
One important extrinsic factor that causes foot deformity and pain in women is footwear. Women's sports shoes are designed as smaller versions of men's shoes. Based on this, the current study aims to identify foot shape in 1,236 Chinese young adult men and 1,085 Chinese young adult women. Three-dimensional foot shape data were collected through video filming. Nineteen foot shape variables were measured, including girth (4 variables), length (4 variables), width (3 variables), height (7 variables), and angle (1 variable). A comparison of foot measures within the range of the common foot length (FL) categories indicates that women showed significantly smaller values of foot measures in width, height, and girth than men. Three foot types were classified, and distributions of different foot shapes within the same FL were found between women and men. Foot width, medial ball length, ball angle, and instep height showed significant differences among foot types in the same FL for both genders. There were differences in the foot shape between Chinese young women and men, which should be considered in the design of Chinese young adults' sports shoes.
Bennour, Sami; Ulrich, Baptiste; Legrand, Thomas; Jolles, Brigitte M; Favre, Julien
2018-01-03
Improving lower-limb flexion/extension angles during walking is important for the treatment of numerous pathologies. Currently, these gait retraining procedures are mostly qualitative, often based on visual assessment and oral instructions. This study aimed to propose an alternative method combining motion capture and display of target footprints on the floor. The second objectives were to determine the error in footprint modifications and the effects of footprint modifications on lower-limb flexion/extension angles. An augmented-reality system made of an optoelectronic motion capture device and video projectors displaying target footprints on the floor was designed. 10 young healthy subjects performed a series of 27 trials, consisting of increased and decreased amplitudes in stride length, step width and foot progression angle. 11 standard features were used to describe and compare lower-limb flexion/extension angles among footprint modifications. Subjects became accustomed to walk on target footprints in less than 10 min, with mean (± SD) precision of 0.020 ± 0.002 m in stride length, 0.022 ± 0.006 m in step width, and 2.7 ± 0.6° in progression angle. Modifying stride length had significant effects on 3/3 hip, 2/4 knee and 4/4 ankle features. Similarly, step width and progression angle modifications affected 2/3 and 1/3 hip, 2/4 and 1/4 knee as well as 3/4 and 2/4 ankle features, respectively. In conclusion, this study introduced an augmented-reality method allowing healthy subjects to modify their footprint parameters rapidly and precisely. Walking with modified footprints changed lower-limb sagittal-plane kinematics. Further research is needed to design rehabilitation protocols for specific pathologies. Copyright © 2017 Elsevier Ltd. All rights reserved.
Farokhmanesh, Khatere; Shirzadian, Toraj; Mahboubi, Mohammad; Shahri, Mina Neyakan
2014-01-01
Based on clinical observations, foot hyperpronation is very common. Excessive pronation (hyperpronation) can cause malalignment of the lower extremities. This most often leads to functional and structural deficits. The aim of this study was to assess the effect of foot hyperpronation on lumbar lordosis and thoracic kyphosis. Thirty five healthy subjects (age range, 18030 years) were asked to stand on 4 positions including a flat surface (normal position) and on wedges angled at 10, 15, and 20 degrees. Sampling was done using simple random sampling. Measurements were made by a motion analysis system. For data analysis, the SPSS software (ver. 18) using paired t-test and repeated measures analysis of variance (ANOVA) was applied. The eversion created by the wedges caused a significant increase in lumbar lordosis and thoracic kyphosis. The most significant change occurred between two consecutive positions of flat surface and the first wedge. The t-test for repeated measures showed a high correlation between each two consecutive positions. The results showed that with increased bilateral foot pronation, lumbar lordosis and thoracic kyphosis increased as well. In fact, each of these results is a compensation phenomenon. Further studies are required to determine long-term results of excessive foot pronation and its probable effect on damage progression. PMID:25169004
Farokhmanesh, Khatere; Shirzadian, Toraj; Mahboubi, Mohammad; Shahri, Mina Neyakan
2014-06-17
Based on clinical observations, foot hyperpronation is very common. Excessive pronation (hyperpronation) can cause malalignment of the lower extremities. This most often leads to functional and structural deficits. The aim of this study was to assess the effect of foot hyperpronation on lumbar lordosis and thoracic kyphosis. Thirty five healthy subjects (age range, 18030 years) were asked to stand on 4 positions including a flat surface (normal position) and on wedges angled at 10, 15, and 20 degrees. Sampling was done using simple random sampling. Measurements were made by a motion analysis system. For data analysis, the SPSS software (ver. 18) using paired t-test and repeated measures analysis of variance (ANOVA) was applied. The eversion created by the wedges caused a significant increase in lumbar lordosis and thoracic kyphosis. The most significant change occurred between two consecutive positions of flat surface and the first wedge. The t-test for repeated measures showed a high correlation between each two consecutive positions. The results showed that with increased bilateral foot pronation, lumbar lordosis and thoracic kyphosis increased as well. In fact, each of these results is a compensation phenomenon. Further studies are required to determine long-term results of excessive foot pronation and its probable effect on damage progression.
Xu, Junkai; Bao, Tian; Lee, Ung Hee; Kinnaird, Catherine; Carender, Wendy; Huang, Yangjian; Sienko, Kathleen H; Shull, Peter B
2017-10-11
Postural balance and gait training is important for treating persons with functional impairments, however current systems are generally not portable and are unable to train different types of movements. This paper describes a proof-of-concept design of a configurable, wearable sensing and feedback system for real-time postural balance and gait training targeted for home-based treatments and other portable usage. Sensing and vibrotactile feedback are performed via eight distributed, wireless nodes or "Dots" (size: 22.5 × 20.5 × 15.0 mm, weight: 12.0 g) that can each be configured for sensing and/or feedback according to movement training requirements. In the first experiment, four healthy older adults were trained to reduce medial-lateral (M/L) trunk tilt while performing balance exercises. When trunk tilt deviated too far from vertical (estimated via a sensing Dot on the lower spine), vibrotactile feedback (via feedback Dots placed on the left and right sides of the lower torso) cued participants to move away from the vibration and back toward the vertical no feedback zone to correct their posture. A second experiment was conducted with the same wearable system to train six healthy older adults to alter their foot progression angle in real-time by internally or externally rotating their feet while walking. Foot progression angle was estimated via a sensing Dot adhered to the dorsal side of the foot, and vibrotactile feedback was provided via feedback Dots placed on the medial and lateral sides of the mid-shank cued participants to internally or externally rotate their foot away from vibration. In the first experiment, the wearable system enabled participants to significantly reduce trunk tilt and increase the amount of time inside the no feedback zone. In the second experiment, all participants were able to adopt new gait patterns of internal and external foot rotation within two minutes of real-time training with the wearable system. These results suggest that the configurable, wearable sensing and feedback system is portable and effective for different types of real-time human movement training and thus may be suitable for home-based or clinic-based rehabilitation applications.
Xu, James Y; Nan, Xiaomeng; Ebken, Victor; Wang, Yan; Pottie, Greg J; Kaiser, William J
2015-03-01
Today, the bicycle is utilized as a daily commute tool, a physical rehabilitation asset, and sporting equipment, prompting studies into the biomechanics of cycling. Of the number of important parameters that affect cycling efficiency, the foot angle profile is one of the most important as it correlates directly with the effective force applied to the bike. However, there has been no compact and portable solution for measuring the foot angle and for providing the cyclist with real-time feedback due to a number of difficulties of the current tracking and sensing technologies and the myriad types of bikes available. This paper presents a novel sensing and mobile computing system for classifying the foot angle profiles during cycling and for providing real-time guidance to the user to achieve the correct profile. Continuous foot angle tracking is firstly converted into a discrete problem requiring only recognition of acceleration profiles of the foot using a single shoe mounted tri-axial accelerometer during each pedaling cycle. A classification method is then applied to identify the pedaling profile. Finally, a mobile solution is presented to provide real-time signal processing and guidance.
Wagner, David W; Reed, Matthew P; Chaffin, Don B
2010-11-01
Accurate prediction of foot placements in relation to hand locations during manual materials handling tasks is critical for prospective biomechanical analysis. To address this need, the effects of lifting task conditions and anthropometric variables on foot placements were studied in a laboratory experiment. In total, 20 men and women performed two-handed object transfers that required them to walk to a shelf, lift an object from the shelf at waist height and carry the object to a variety of locations. Five different changes in the direction of progression following the object pickup were used, ranging from 45° to 180° relative to the approach direction. Object weights of 1.0 kg, 4.5 kg, 13.6 kg were used. Whole-body motions were recorded using a 3-D optical retro-reflective marker-based camera system. A new parametric system for describing foot placements, the Quantitative Transition Classification System, was developed to facilitate the parameterisation of foot placement data. Foot placements chosen by the subjects during the transfer tasks appeared to facilitate a change in the whole-body direction of progression, in addition to aiding in performing the lift. Further analysis revealed that five different stepping behaviours accounted for 71% of the stepping patterns observed. More specifically, the most frequently observed behaviour revealed that the orientation of the lead foot during the actual lifting task was primarily affected by the amount of turn angle required after the lift (R(2) = 0.53). One surprising result was that the object mass (scaled by participant body mass) was not found to significantly affect any of the individual step placement parameters. Regression models were developed to predict the most prevalent step placements and are included in this paper to facilitate more accurate human motion simulations and ergonomics analyses of manual material lifting tasks. STATEMENT OF RELEVANCE: This study proposes a method for parameterising the steps (foot placements) associated with manual material handling tasks. The influence of task conditions and subject anthropometry on the foot placements of the most frequently observed stepping pattern during a laboratory study is discussed. For prospective postural analyses conducted using digital human models, accurate prediction of the foot placements is critical to realistic postural analyses and improved biomechanical job evaluations.
Characteristics of Selected Anthropometric Foot Indicators in Physically Active Students.
Bac, Aneta; Bogacz, Gabriela; Ogrodzka-Ciechanowicz, Katarzyna; Kulis, Aleksandra; Szaporów, Tomasz; Woźniacka, Renata; Radlińska, Natalia
2018-05-01
The aim of this study was to determine the type of medial longitudinal arch (MLA) in students of Krakow universities, investigate the relationship between physical activity and the shaping of the feet, and examine the relationship between hallux valgus angle and the type of footwear chosen most often. The study group consisted of 120 students, of which 56 respondents were students of the University School of Physical Education in Krakow, whereas the remaining 64 respondents were students of the Pedagogical University of Krakow. To evaluate the MLA, a podoscope was used, which allowed us to determine the length and width of the foot, and calculation of the Clarke angle, heel angle γ, and the angle of hallux valgus. All students were also subjected to a measurement of body weight and height. There was a statistically significant relationship between physical activity and the Clarke angle in the group of women studying at the University School of Physical Education. There was no correlation between the hallux valgus angle and the type of footwear chosen most often in the research groups. The most frequently diagnosed type of longitudinal and transverse arch foot in the research group was normal MLA. There was no relationship between physical activity and transverse arch foot in any of the research groups.
Su, Yanling; Chen, Wei; Zhang, Tao; Wu, Xingwang; Wu, Zhanpo; Zhang, Yingze
2013-09-24
Controversy exits over the role of Böhler's angle in assessing the injury severity of displaced intra-articular calcaneal fractures and predicting the functional outcome following internal fixation. This study aims to investigate whether a correlation exists between Böhler's angle and the injury severity of displaced calcaneal fractures, and between surgical improvement of Böhler's angle and functional outcome. Patients treated operatively for unilateral closed displaced intra-articular calcaneal fractures from January 1, 2004 to March 31, 2008 were identified. The Böhler's angles of both calcaneus were measured, and the measurement of the uninjured foot was used as its normal control. The difference in the value of Böhler's angle measured preoperatively or postoperatively between the angle of the injured foot and that of the contralateral calcaneus were calculated, respectively. The change in Böhler's angle by ratio was calculated by dividing the difference value of Böhler's angle between bilateral calcaneus by its normal control. The injury severity was assessed according to Sanders classification. The functional outcomes were assessed using American Orthopaedic Foot & Ankle Society hindfoot scores. 274 patients were included into the study with a mean follow-up duration of 71 months. According to Sanders classification, the fracture pattern included 105 type II, 121 type III and 48 type IV fractures. According to American Orthopaedic Foot & Ankle Society hindfoot scoring system, the excellent, good, fair and poor results were achieved in 104, 132, 27, and 11 patients, respectively. The preoperative Böhler's angle, difference value of Böhler's angle between bilateral calcaneus, and change in Böhler's angle by ratio each has a significant correlation with Sanders classification (rs=-0.178, P=0.003; rs=-0.174, P=0.004; rs=-0.172, P=0.005, respectively), however, is not correlated with functional outcome individually. The three postoperative measurements were all found to have a significant correlation with American Orthopaedic Foot & Ankle Society hindfoot scores (rs=0.223, P<0.001; rs=0.224, P<0.001; rs=0.220, P<0.001, respectively). However, these correlations were all weak to low. There was a significant correlation between preoperative Böhler's angle and the injury severity of displaced intra-articular calcaneal fractures, but only postoperative Böhler's angle parameters were found to have a significant correlation with the functional recovery.
Fredericks, William; Swank, Seth; Teisberg, Madeline; Hampton, Bethany; Ridpath, Lance; Hanna, Jandy B
2015-06-01
Minimalist running footwear has grown increasingly popular. Prior studies that have compared lower extremity biomechanics in minimalist running to traditional running conditions are largely limited to a single running velocity. This study compares the effects of running at various speeds on foot strike pattern, stride length, knee angles and ankle angles in traditional, barefoot, and minimalist running conditions. Twenty-six recreational runners (19-46 years of age) ran on a treadmill at a range of speeds (2.5-4.0 m·sec(-1)). Subjects ran with four different footwear conditions: personal, standard, and minimalist shoes and barefoot. 3D coordinates from video data were collected. The relationships between speed, knee and ankle angles at foot strike and toe-off, relative step length, and footwear conditions were evaluated by ANCOVA, with speed as the co-variate. Distribution of non-rearfoot strike was compared across shod conditions with paired t-tests. Non-rearfoot strike distribution was not significantly affected by speed, but was different between shod conditions (p < 0.05). Footwear condition and speed significantly affected ankle angle at touchdown, independent of one another (F [3,71] = 10.28, p < 0.001), with barefoot and minimalist running exhibiting greater plantarflexion at foot strike. When controlling for foot strike style, barefoot and minimalist runners exhibited greater plantarflexion than other conditions (p < 0.05). Ankle angle at lift-off and relative step length exhibited a significant interaction between speed and shod condition. Knee angles had a significant relationship with speed, but not with footwear. There is a clear influence of footwear, but not speed, on foot strike pattern. Additionally, speed and footwear predict ankle angles (greater plantarflexion at foot strike) and may have implications for minimalist runners and their risk of injury. Long-term studies utilizing various speeds and habituation times are needed. Key pointsFoot strike style does not change with speed, but does change with shod condition, with minimalist shoes exhibiting an intermediate distribution of forefoot strikes between barefoot and traditional shoes.Plantarflexion at touchdown does change with speed and with shoe type, with barefoot and minimalist shoes exhibiting a greater plantarflexion angle than traditional running shoes.Knee angles change with speed in all shod conditions, but knee flexion at touchdown is not different between shod conditions.Relative step length changes with speed and shod condition, but there is an interaction between these variables such that step length increases more quickly in traditional shoes as speed increases.
Fredericks, William; Swank, Seth; Teisberg, Madeline; Hampton, Bethany; Ridpath, Lance; Hanna, Jandy B.
2015-01-01
Minimalist running footwear has grown increasingly popular. Prior studies that have compared lower extremity biomechanics in minimalist running to traditional running conditions are largely limited to a single running velocity. This study compares the effects of running at various speeds on foot strike pattern, stride length, knee angles and ankle angles in traditional, barefoot, and minimalist running conditions. Twenty-six recreational runners (19-46 years of age) ran on a treadmill at a range of speeds (2.5-4.0 m·sec-1). Subjects ran with four different footwear conditions: personal, standard, and minimalist shoes and barefoot. 3D coordinates from video data were collected. The relationships between speed, knee and ankle angles at foot strike and toe-off, relative step length, and footwear conditions were evaluated by ANCOVA, with speed as the co-variate. Distribution of non-rearfoot strike was compared across shod conditions with paired t-tests. Non-rearfoot strike distribution was not significantly affected by speed, but was different between shod conditions (p < 0.05). Footwear condition and speed significantly affected ankle angle at touchdown, independent of one another (F [3,71] = 10.28, p < 0.001), with barefoot and minimalist running exhibiting greater plantarflexion at foot strike. When controlling for foot strike style, barefoot and minimalist runners exhibited greater plantarflexion than other conditions (p < 0.05). Ankle angle at lift-off and relative step length exhibited a significant interaction between speed and shod condition. Knee angles had a significant relationship with speed, but not with footwear. There is a clear influence of footwear, but not speed, on foot strike pattern. Additionally, speed and footwear predict ankle angles (greater plantarflexion at foot strike) and may have implications for minimalist runners and their risk of injury. Long-term studies utilizing various speeds and habituation times are needed. Key points Foot strike style does not change with speed, but does change with shod condition, with minimalist shoes exhibiting an intermediate distribution of forefoot strikes between barefoot and traditional shoes. Plantarflexion at touchdown does change with speed and with shoe type, with barefoot and minimalist shoes exhibiting a greater plantarflexion angle than traditional running shoes. Knee angles change with speed in all shod conditions, but knee flexion at touchdown is not different between shod conditions. Relative step length changes with speed and shod condition, but there is an interaction between these variables such that step length increases more quickly in traditional shoes as speed increases. PMID:25983575
Branthwaite, Helen; Chockalingam, Nachiappan; Greenhalgh, Andrew; Chatzistergos, Panagiotis
2014-09-01
Uncomfortable shoes have been attributed to poor fit and the cause of foot pathologies. Assessing and evaluating comfort and fit have proven challenging due to the subjective nature. The aim of this paper is to investigate the relationship between footwear characteristics and perceived comfort. Twenty-seven females assessed three different styles of ballet pump shoe for comfort using a comfort scale whilst walking along a 20 m walkway. The physical characteristics of the shoes and the progression of centre of pressure during walking were assessed. There were significant physical differences between each style, square shoe being the shortest, widest and stiffest and round shoe having the least volume at the toe box. Centre of pressure progression angle was centralised to the longitudinal axis of the foot when wearing each of the three shoes compared to barefoot. Length, width and cantilever bending stiffness had no impact on perceived comfort. Wearing snug fitting flexible soled round ballet flat pump is perceived to be the most comfortable of the shoe shapes tested producing a faster more efficient gait. Further investigations are required to assess impact/fit and upper material on perceived comfort to aid consumers with painful feet in purchasing shoes. Copyright © 2014 Elsevier Ltd. All rights reserved.
Value of the fetal plantar shape in prenatal diagnosis of talipes equinovarus.
Liao, Huifang; Cai, Ailu; Wang, Bing; Wang, Xiaoguang; Yan, Zhen; Li, Jingyu
2012-07-01
The purpose of this study was to evaluate the value of the fetal plantar shape in prenatal diagnosis of talipes equinovarus. A case-control study was conducted between September 2009 and February 2011. We measured the width and length of 249 feet (156 fetuses) included in this study and then calculated the width to length ratio. All of the fetuses were followed to obtain the pregnancy outcomes and confirm whether the deformity existed; then the bimalleolar angle of each foot with talipes equinovarus was measured. Independent samples t tests were performed to compare the foot width, length, and width to length ratio between normal and talipes equinovarus groups. We also assessed the correlation between the width to length ratio and bimalleolar angle in the talipes equinovarus cases with the Pearson correlation coefficient. Statistically significant differences were shown between the two groups (P< .001) for the three foot measurements, and a significant negative correlation was found between the width to length ratio and bimalleolar angle of the affected foot (r = -0.857). The fetal plantar shape can provide valuable information for prenatal diagnosis of clubfoot. Compared with a normal foot, a clubfoot tends to be wider and shorter. A higher width to length ratio is associated with a smaller bimalleolar angle and indicates a more severe talipes equinovarus deformity.
Boldt, Andrew R; Willson, John D; Barrios, Joaquin A; Kernozek, Thomas W
2013-02-01
We examined the effects of medially wedged foot orthoses on knee and hip joint mechanics during running in females with and without patellofemoral pain syndrome (PFPS). We also tested if these effects depend on standing calcaneal eversion angle. Twenty female runners with and without PFPS participated. Knee and hip joint transverse and frontal plane peak angle, excursion, and peak internal knee and hip abduction moment were calculated while running with and without a 6° full-length medially wedged foot orthoses. Separate 3-factor mixed ANOVAs (group [PFPS, control] x condition [medial wedge, no medial wedge] x standing calcaneal angle [everted, neutral, inverted]) were used to test the effect of medially wedged orthoses on each dependent variable. Knee abduction moment increased 3% (P = .03) and hip adduction excursion decreased 0.6° (P < .01) using medially wedged foot orthoses. No significant group x condition or calcaneal angle x condition effects were observed. The addition of medially wedged foot orthoses to standardized running shoes had minimal effect on knee and hip joint mechanics during running thought to be associated with the etiology or exacerbation of PFPS symptoms. These effects did not appear to depend on injury status or standing calcaneal posture.
Arch index and running biomechanics in children aged 10-14 years.
Hollander, Karsten; Stebbins, Julie; Albertsen, Inke Marie; Hamacher, Daniel; Babin, Kornelia; Hacke, Claudia; Zech, Astrid
2018-03-01
While altered foot arch characteristics (high or low) are frequently assumed to influence lower limb biomechanics and are suspected to be a contributing factor for injuries, the association between arch characteristics and lower limb running biomechanics in children is unclear. Therefore, the aim of this study was to investigate the relationship between a dynamically measured arch index and running biomechanics in healthy children. One hundred and one children aged 10-14 years were included in this study and underwent a biomechanical investigation. Plantar distribution (Novel, Emed) was used to determine the dynamic arch index and 3D motion capture (Vicon) to measure running biomechanics. Linear mixed models were established to determine the association between dynamic arch index and foot strike patterns, running kinematics, kinetics and temporal-spatial outcomes. No association was found between dynamic arch index and rate of rearfoot strikes (p = 0.072). Of all secondary outcomes, only the foot progression angle was associated with the dynamic arch index (p = 0.032) with greater external rotation in lower arched children. Overall, we found only few associations between arch characteristics and running biomechanics in children. However, altered foot arch characteristics are of clinical interest. Future studies should focus on detailed foot biomechanics and include clinically diagnosed high and low arched children. Copyright © 2018 Elsevier B.V. All rights reserved.
NASA Technical Reports Server (NTRS)
Underwood, J. M.; Parrell, H.
1976-01-01
The investigation was conducted in the NASA/Ames Research Center 12-foot Pressure Tunnel. The model was a Langley-built 0.015-scale SSV orbiter model with remote independently operated left and right elevon surfaces. The objective of the test was to generate a detailed aerodynamic data base for the current shuttle orbiter configuration. Special attention was directed to definition of nonlinear aerodynamic characteristics by taking data at small increments in angle of attack, angle of sideslip, and elevon position. Six-component aerodynamic force and moment and elevon position data were recorded over an angle of attack range from -4 deg to 24 deg at angles of sideslip of 0 deg and + or - 4 deg. Additional tests were made over an angle of sideslip range from -6 deg to 6 deg at selected angles of attack. The test Mach numbers were 0.22 and 0.29 and the Reynolds number was varied from 2.0 to 8.5 million per foot.
Hastings, Mary K; Woodburn, James; Mueller, Michael J; Strube, Michael J; Johnson, Jeffrey E; Beckert, Krista S; Stein, Michelle L; Sinacore, David R
2014-01-01
Diabetic foot deformity onset and progression maybe associated with abnormal foot and ankle motion. The modified Oxford multi-segmental foot model allows kinematic assessment of inter-segmental foot motion. However, there are insufficient anatomical landmarks to accurately representation the alignment of the hindfoot and forefoot segments during model construction. This is most notable for the sagittal plane which is referenced parallel to the floor, allowing comparison of inter-segmental excursion but not capturing important sagittal hind-to-forefoot deformity associated with diabetic foot disease and can potentially underestimate true kinematic differences. The purpose of the study was to compare walking kinematics using local coordinate systems derived from the modified Oxford model and the radiographic directed model which incorporated individual calcaneal and 1st metatarsal declination pitch angles for the hindfoot and forefoot. We studied twelve participants in each of the following groups: (1) diabetes mellitus, peripheral neuropathy and medial column foot deformity (DMPN+), (2) DMPN without medial column deformity (DMPN-) and (3) age- and weight-match controls. The modified Oxford model coordinate system did not identify differences between groups in the initial, peak, final, or excursion hindfoot relative to shank or forefoot relative to hindfoot dorsiflexion/plantarflexion during walking. The radiographic coordinate system identified the DMPN+ group to have an initial, peak and final position of the forefoot relative to hindfoot that was more dorsiflexed (lower arch phenotype) than the DMPN- group (p<.05). Use of radiographic alignment in kinematic modeling of those with foot deformity reveals segmental motion occurring upon alignment indicative of a lower arch. Copyright © 2014 Elsevier B.V. All rights reserved.
Klein, Christian; Kinz, Wieland; Zembsch, Alexander; Groll-Knapp, Elisabeth; Kundi, Michael
2014-04-21
Currently, the metatarsophalangeal angle (hallux valgus angle) is measured based on radiographic images. However, using X-ray examinations for epidemiological or screening purposes would be unethical, especially in children. For this reason it is discussed to measure the hallux valgus angle of the margo medialis pedis (medial border of the foot) documented on foot outline drawings or foot scans. As a first step on the way to prove the validity of those approaches this study assesses the hallux valgus angle measured on the margo medialis pedis based on the same x-ray pictures as the metatarsophalangeal hallux valgus. Radiographic images of the foot were obtained from patients with symptomatic hallux valgus malformation. Twelve sets of contact copies of the 63 originals were made, and were marked and measured according to three different methods, each one performed by two observers and with two repeated measurements. Thus, data sets from 756 individual assessments were entered into the multifactorial statistical analysis.Comparisons were made between the angle of the margo medialis pedis and the metatarsophalangeal angle, which was determined by two different methods. To determine the inter- and intraobserver reliability of the different methods, each assessment was conducted by two independent experts and repeated after a period of several weeks. The correlations between the hallux valgus angles determined by the three different methods were all above r=0.89 (p<0.001) and thus highly significant. The values obtained by measuring the margo medialis pedis angle, however, were on average 4.8 degrees smaller than the metatarsophalangeal angles. No significant differences were found between the observers. No systematic deviations for any observer between repeated measurements were detected. Measurements of the radiographic hallux angle of the margo medialis pedis are reliable and show high correlation with the metatarsophalangeal angle. Because the hallux valgus angles based on margo medialis pedis measurements were slightly but statistically significantly smaller, these measurements should be considered conservative estimates of the metatarsophalangeal angle. Significant differences between hallux valgus angles based on radiographic and non-radiographic material are unlikely. However this question has to be treated in a second stage in detail.
Initial foot contact and related kinematics affect impact loading rate in running.
Breine, Bastiaan; Malcolm, Philippe; Van Caekenberghe, Ine; Fiers, Pieter; Frederick, Edward C; De Clercq, Dirk
2017-08-01
This study assessed kinematic differences between different foot strike patterns and their relationship with peak vertical instantaneous loading rate (VILR) of the ground reaction force (GRF). Fifty-two runners ran at 3.2 m · s -1 while we recorded GRF and lower limb kinematics and determined foot strike pattern: Typical or Atypical rearfoot strike (RFS), midfoot strike (MFS) of forefoot strike (FFS). Typical RFS had longer contact times and a lower leg stiffness than Atypical RFS and MFS. Typical RFS showed a dorsiflexed ankle (7.2 ± 3.5°) and positive foot angle (20.4 ± 4.8°) at initial contact while MFS showed a plantar flexed ankle (-10.4 ± 6.3°) and more horizontal foot (1.6 ± 3.1°). Atypical RFS showed a plantar flexed ankle (-3.1 ± 4.4°) and a small foot angle (7.0 ± 5.1°) at initial contact and had the highest VILR. For the RFS (Typical and Atypical RFS), foot angle at initial contact showed the highest correlation with VILR (r = -0.68). The observed higher VILR in Atypical RFS could be related to both ankle and foot kinematics and global running style that indicate a limited use of known kinematic impact absorbing "strategies" such as initial ankle dorsiflexion in MFS or initial ankle plantar flexion in Typical RFS.
2010-01-01
Background For large scale epidemiological studies clinical assessments and radiographs can be impractical and expensive to apply to more than just a sample of the population examined. The study objectives were to develop and validate two novel instruments for self-reported knee malalignment and foot rotation suitable for use in questionnaire studies of knee pain and osteoarthritis. Methods Two sets of line drawings were developed using similar methodology. Each instrument consisted of an explanatory question followed by a set of drawings showing straight alignment, then two each at 7.5° angulation and 15° angulation in the varus/valgus (knee) and inward/outward (foot) directions. Forty one participants undertaking a community study completed the instruments on two occasions. Participants were assessed once by a blinded expert clinical observer with demonstrated excellent reproducibility. Validity was assessed by sensitivity, specificity and likelihood ratio (LR) using the observer as the reference standard. Reliability was assessed using weighted kappa (κ). Knee malalignment was measured on 400 knee radiographs. General linear model was used to assess for the presence of a linear increase in knee alignment angle (measured medially) from self-reported severe varus to mild varus, straight, mild valgus and severe valgus deformity. Results Observer reproducibility (κ) was 0.89 and 0.81 for the knee malalignment and foot rotation instruments respectively. Self-reported participant reproducibility was also good for the knee (κ 0.73) and foot (κ 0.87) instruments. Validity was excellent for the knee malalignment instrument, with a sensitivity of 0.74 (95%CI 0.54, 0.93) and specificity of 0.97 (95%CI 0.94, 1.00). Similarly the foot rotation instrument was also found to have high sensitivity (0.92, 95%CI 0.83, 1.01) and specificity (0.96, 95%CI 0.93, 1.00). The knee alignment angle increased progressively from self reported severe varus to mild varus, straight, mild valgus and severe valgus knee malalignment (ptrend <0.001). Conclusions The two novel instruments appear to provide a valid and reliable assessment of self-reported knee malalignment and foot rotation, and may have a practical use in epidemiological studies. PMID:20565825
[Anlysis of foot biomechanics characteristic in 303 patients with type 2 diabetes mellitus].
Li, Wen-Xia; Cao, Ying; Zou, Meng-Chen; Huang, Ying; Hu, Ping; Luo, Xiang-Rong; Jiang, Ya; Xue, Yao-Ming; Gao, Fang
2016-10-20
To investigate foot biomechanics characteristic of patients with type 2 diabetes mellitus. This study was conducted among 303 patients with type 2 diabetes. The whole foot was divided into 10 regions, namely the first toe (T1); the second to fifth toes (T2-5); the first, second, third, fourth, and fifth metatarsals (M1, M2, M3, M4, and M5, respectively); midfoot (MF), and the heel medial (HM). Foot arch index, foot angle and maximum peak pressure (MPP) of the 10 regions were measured using a Footscan gait system. The maximum peak pressure of 10 regions decreased in the order of M3>M2>HM>M4>HL>M1>M5>T1>ML>T2-5 for the left foot, and in the order of M3>M2>HM>M4>HL>M1>M5>T1>ML>T2-5 for the right foot. The MPP in M1 region was higher in the right than in the left foot (P<0.05). The MPP in M3, M4, M5, and MF was higher in the left than in the right foot (P<0.05). The percentage of high-risk foot (defined by a total plantar pressure ≥70 N/cm 2 ) was 34% on the left and 17.7% on the right. An increased BMI was associated with a significant increase in high-risk foot, but not for the right foot in underweight patients. Foot flat phase was extended and forefoot push-off phase shortened in stance phase in the patients. Compared with the right foot, the left foot showed a significantly increased foot arch index and increased low and high arch rates with a decreased normal arch rate. Total plantar pressure was higher in of the left high arch foot than in normal arch foot. The foot angle was significantly larger on the right than on the left. The bilateral total plantar pressures were significantly greater in male patients (P<0.05) and increased with age but were not associated with the duration of DM, foot angle, or glycosylated hemoglobin level. Diabetic patients have obvious alterations in foot biomechanics with abnormalities of the plantar pressure, and the percentage of high-risk foot increases in overweight and obese patients, suggesting the need of body weight control in these patients when administering offloading treatment for prevention of diabetic foot ulcer.
Foot Placement Modification for a Biped Humanoid Robot with Narrow Feet
Hattori, Kentaro; Otani, Takuya; Lim, Hun-Ok; Takanishi, Atsuo
2014-01-01
This paper describes a walking stabilization control for a biped humanoid robot with narrow feet. Most humanoid robots have larger feet than human beings to maintain their stability during walking. If robot's feet are as narrow as humans, it is difficult to realize a stable walk by using conventional stabilization controls. The proposed control modifies a foot placement according to the robot's attitude angle. If a robot tends to fall down, a foot angle is modified about the roll axis so that a swing foot contacts the ground horizontally. And a foot-landing point is also changed laterally to inhibit the robot from falling to the outside. To reduce a foot-landing impact, a virtual compliance control is applied to the vertical axis and the roll and pitch axes of the foot. Verification of the proposed method is conducted through experiments with a biped humanoid robot WABIAN-2R. WABIAN-2R realized a knee-bended walking with 30 mm breadth feet. Moreover, WABIAN-2R mounted on a human-like foot mechanism mimicking a human's foot arch structure realized a stable walking with the knee-stretched, heel-contact, and toe-off motion. PMID:24592154
Foot placement modification for a biped humanoid robot with narrow feet.
Hashimoto, Kenji; Hattori, Kentaro; Otani, Takuya; Lim, Hun-Ok; Takanishi, Atsuo
2014-01-01
This paper describes a walking stabilization control for a biped humanoid robot with narrow feet. Most humanoid robots have larger feet than human beings to maintain their stability during walking. If robot's feet are as narrow as humans, it is difficult to realize a stable walk by using conventional stabilization controls. The proposed control modifies a foot placement according to the robot's attitude angle. If a robot tends to fall down, a foot angle is modified about the roll axis so that a swing foot contacts the ground horizontally. And a foot-landing point is also changed laterally to inhibit the robot from falling to the outside. To reduce a foot-landing impact, a virtual compliance control is applied to the vertical axis and the roll and pitch axes of the foot. Verification of the proposed method is conducted through experiments with a biped humanoid robot WABIAN-2R. WABIAN-2R realized a knee-bended walking with 30 mm breadth feet. Moreover, WABIAN-2R mounted on a human-like foot mechanism mimicking a human's foot arch structure realized a stable walking with the knee-stretched, heel-contact, and toe-off motion.
NASA Technical Reports Server (NTRS)
Parrell, H.; Gamble, J. D.
1977-01-01
Transonic Wind Tunnel tests were run on a .015 scale model of the space shuttle orbiter vehicle in the 8-foot transonic wind tunnel. Purpose of the test program was to obtain basic shuttle aerodynamic data through a full range of elevon and aileron deflections, verification of data obtained at other facilities, and effects of Reynolds number. Tests were performed at Mach numbers from .35 to 1.20 and Reynolds numbers from 3,500,000 to 8,200,000 per foot. The high Reynolds number conditions (nominal 8,000,000/foot) were obtained using the ejector augmentation system. Angle of attack was varied from -2 to +20 degrees at sideslip angles of -2, 0, and +2 degrees. Sideslip was varied from -6 to +8 degrees at constant angles of attack from 0 to +20 degrees. Aileron settings were varied from -5 to +10 degrees at elevon deflections of -10, 0, and +10 degrees. Fixed aileron settings of 0 and 2 degrees in combination with various fixed elevon settings between -20 and +5 degrees were also run at varying angles of attack.
Ficanha, Evandro M; Rastgaar, Mohammad; Kaufman, Kenton R
2015-01-01
The ankle joint of currently available powered prostheses is capable of controlling one degree of freedom (DOF), focusing on improved mobility in the sagittal plane. To increase agility, the requirements of turning in prosthesis design need to be considered. Ankle kinematics and kinetics were studied during sidestep cutting and straight walking. There were no significant differences between the ankle sagittal plane mechanics when comparing sidestep cutting and straight walking; however, significant differences were observed in ankle frontal plane mechanics. During straight walking, the inversion-eversion (IE) angles were smaller than with sidestep cutting. The ankle that initiated the sidestep cutting showed progressively increasing inversion from 2 to 13 degrees while the following contralateral step showed progressively decreasing inversion from 8 to -4 degrees during normal walking speed. The changes in IE kinematics were the most significant during sidestep cutting compared with straight walking. The IE moments of the step that initiated the sidestep cutting were always in eversion, acting as a braking moment opposing the inverting motion. This suggests that an ankle-foot prosthesis with active DOFs in the sagittal and frontal planes will increase the agility of gait for patients with limb loss.
Lee, Jinkyu; Hong, Yoon No Gregory; Shin, Choongsoo S
2016-07-01
The mid-foot contact area relative to the total foot contact area can facilitate foot arch structure evaluation. A stair descent motion consistently provides initial fore-foot contact and utilizes the foot arch more actively for energy absorption. The purpose of this study was to compare ankle and knee joint angle, moment, and work in sagittal plane during stair descending between low and high Mid-Foot-Contact-Area (MFCA) ratio group. The twenty-two female subjects were tested and classified into two groups (high MFCA and low MFCA) using their static MFCA ratios. The ground reaction force (GRF) and kinematics of ankle and knee joints were measured while stair descending. During the period between initial contact and the first peak in vertical GRF (early absorption phase), ankle negative work for the low MFCA ratio group was 33% higher than that for the high MFCA ratio group (p<0.05). However, ankle negative work was not significantly different between the two groups during the period between initial contact and peak dorsiflexion angle (early absorption phase+late absorption phase). The peak ankle dorsiflexion angle was smaller in the low MFCA ratio group (p<0.05). Our results suggest that strategy of energy absorption at the ankle and foot differs depending upon foot arch types classified by MFCA. The low MFCA ratio group seemed to absorb more impact energy using strain in the planar fascia during early absorption phase, whereas the high MFCA ratio group absorbed more impact energy using increased dorsiflexion during late absorption phase. Copyright © 2016 Elsevier B.V. All rights reserved.
Kinematic and biomimetic assessment of a hydraulic ankle/foot in level ground and camber walking
Bai, Xuefei; Ewins, David; Crocombe, Andrew D.
2017-01-01
Improved walking comfort has been linked with better bio-mimicking of the prosthetic ankle. This study investigated if a hydraulic ankle/foot can provide enough motion in both the sagittal and frontal planes during level and camber walking and if the hydraulic ankle/foot better mimics the biological ankle moment pattern compared with a fixed ankle/foot device. Five active male unilateral trans-femoral amputees performed level ground walking at normal and fast speeds and 2.5° camber walking in both directions using their own prostheses fitted with an “Echelon” hydraulic ankle/foot and an “Esprit” fixed ankle/foot. Ankle angles and the Trend Symmetry Index of the ankle moments were compared between prostheses and walking conditions. Significant differences between prostheses were found in the stance plantarflexion and dorsiflexion peaks with a greater range of motion being reached with the Echelon foot. The Echelon foot also showed significantly improved bio-mimicry of the ankle resistance moment in all walking conditions, either compared with the intact side of the same subject or with the “normal” mean curve from non-amputees. During camber walking, both types of ankle/foot devices showed similar changes in the frontal plane ankle angles. Results from a questionnaire showed the subjects were more satisfied with Echelon foot. PMID:28704428
Kinematic and biomimetic assessment of a hydraulic ankle/foot in level ground and camber walking.
Bai, Xuefei; Ewins, David; Crocombe, Andrew D; Xu, Wei
2017-01-01
Improved walking comfort has been linked with better bio-mimicking of the prosthetic ankle. This study investigated if a hydraulic ankle/foot can provide enough motion in both the sagittal and frontal planes during level and camber walking and if the hydraulic ankle/foot better mimics the biological ankle moment pattern compared with a fixed ankle/foot device. Five active male unilateral trans-femoral amputees performed level ground walking at normal and fast speeds and 2.5° camber walking in both directions using their own prostheses fitted with an "Echelon" hydraulic ankle/foot and an "Esprit" fixed ankle/foot. Ankle angles and the Trend Symmetry Index of the ankle moments were compared between prostheses and walking conditions. Significant differences between prostheses were found in the stance plantarflexion and dorsiflexion peaks with a greater range of motion being reached with the Echelon foot. The Echelon foot also showed significantly improved bio-mimicry of the ankle resistance moment in all walking conditions, either compared with the intact side of the same subject or with the "normal" mean curve from non-amputees. During camber walking, both types of ankle/foot devices showed similar changes in the frontal plane ankle angles. Results from a questionnaire showed the subjects were more satisfied with Echelon foot.
Design and characterization of a biologically inspired quasi-passive prosthetic ankle-foot.
Mooney, Luke M; Lai, Cara H; Rouse, Elliott J
2014-01-01
By design, commonly worn energy storage and release (ESR) prosthetic feet cannot provide biologically realistic ankle joint torque and angle profiles during walking. Additionally, their anthropomorphic, cantilever architecture causes their mechanical stiffness to decrease throughout the stance phase of walking, opposing the known trend of the biological ankle. In this study, the design of a quasi-passive pneumatic ankle-foot prosthesis is detailed that is able to replicate the biological ankle's torque and angle profiles during walking. The prosthetic ankle is comprised of a pneumatic piston, bending spring and solenoid valve. The mechanical properties of the pneumatic ankle prosthesis are characterized using a materials testing machine and the properties are compared to those from a common, passive ESR prosthetic foot. The characterization spanned a range of ankle equilibrium pressures and testing locations beneath the foot, analogous to the location of center of pressure within the stance phase of walking. The pneumatic ankle prosthesis was shown to provide biologically appropriate trends and magnitudes of torque, angle and stiffness behavior, when compared to the passive ESR prosthetic foot. Future work will focus on the development of a control system for the quasi-passive device and clinical testing of the pneumatic ankle to demonstrate efficacy.
NASA Technical Reports Server (NTRS)
Nowak, R. J.; Albertson, C. W.; Hunt, L. R.
1984-01-01
The effects of free-stream unit Reynolds number, angle of attack, and nose shape on the aerothermal environment of a 3-ft basediameter, 12.5 deg half-angle cone were investigated in the Langley 8-foot high temperature tunnel at Mach 6.7. The average total temperature was 3300 R, the freestream unit Reynolds number ranged from 400,000 to 1,400,000 per foot, and the angle of attack ranged from 0 deg to 10 deg. Three nose configurations were tested on the cone: a 3-in-radius tip, a 1-in-radius tip on an ogive frustum, and a sharp tip on an ogive frustum. Surface-pressure and cold-wall heating-rate distributions were obtained for laminar, transitional temperature in the shock layer were obtained. The location of the start of transition moved forward both on windward and leeward sides with increasing free-stream Reynolds numbers, increasing angle of attack, and decreasing nose bluntness.
The VSPA Foot: A Quasi-Passive Ankle-Foot Prosthesis With Continuously Variable Stiffness.
Shepherd, Max K; Rouse, Elliott J
2017-12-01
Most commercially available prosthetic feet do not exhibit a biomimetic torque-angle relationship, and are unable to modulate their mechanics to assist with other mobility tasks, such as stairs and ramps. In this paper, we present a quasi-passive ankle-foot prosthesis with a customizable torque-angle curve and an ability to quickly modulate ankle stiffness between tasks. The customizable torque-angle curve is obtained with a cam-based transmission and a fiberglass leaf spring. To achieve variable stiffness, the leaf spring's support conditions can be actively modulated by a small motor, shifting the torque-angle curve to be more or less stiff. We introduce the design, characterize the available torque-angle curves, and present kinematics from a transtibial amputee subject performing level-ground walking, stair ascent/descent, and ramp ascent/descent. The subject exhibited a more normative range of motion on stairs and ramps at lower stiffness levels, and preferred different stiffness levels for each task. Paired with an appropriate intent recognition system, our novel ankle prosthesis could improve gait biomechanics during walking and many other mobility tasks.
An Investigation into the Relation between the Technique of Movement and Overload in Step Aerobics
Wysocka, Katarzyna
2017-01-01
The aim of this research was to determine the features of a step workout technique which may be related to motor system overloading in step aerobics. Subjects participating in the research were instructors (n = 15) and students (n = 15) without any prior experience in step aerobics. Kinematic and kinetic data was collected with the use of the BTS SMART system comprised of 6 calibrated video cameras and two Kistler force plates. The subjects' task was to perform basic steps. The following variables were analyzed: vertical, anteroposterior, and mediolateral ground reaction forces; foot flexion and abduction and adduction angles; knee joint flexion angle; and trunk flexion angle in the sagittal plane. The angle of a foot adduction recorded for the instructors was significantly smaller than that of the students. The knee joint angle while stepping up was significantly higher for the instructors compared to that for the students. Our research confirmed that foot dorsal flexion and adduction performed while stepping up increased load on the ankle joint. Both small and large angles of knee flexion while stepping up and down resulted in knee joint injuries. A small trunk flexion angle in the entire cycle of step workout shut down dorsal muscles, which stopped suppressing the load put on the spine. PMID:28348501
2014-01-01
Background Currently, the metatarsophalangeal angle (hallux valgus angle) is measured based on radiographic images. However, using X-ray examinations for epidemiological or screening purposes would be unethical, especially in children. For this reason it is discussed to measure the hallux valgus angle of the margo medialis pedis (medial border of the foot) documented on foot outline drawings or foot scans. As a first step on the way to prove the validity of those approaches this study assesses the hallux valgus angle measured on the margo medialis pedis based on the same x-ray pictures as the metatarsophalangeal hallux valgus. Methods Radiographic images of the foot were obtained from patients with symptomatic hallux valgus malformation. Twelve sets of contact copies of the 63 originals were made, and were marked and measured according to three different methods, each one performed by two observers and with two repeated measurements. Thus, data sets from 756 individual assessments were entered into the multifactorial statistical analysis. Comparisons were made between the angle of the margo medialis pedis and the metatarsophalangeal angle, which was determined by two different methods. To determine the inter- and intraobserver reliability of the different methods, each assessment was conducted by two independent experts and repeated after a period of several weeks. Results The correlations between the hallux valgus angles determined by the three different methods were all above r = 0.89 (p < 0.001) and thus highly significant. The values obtained by measuring the margo medialis pedis angle, however, were on average 4.8 degrees smaller than the metatarsophalangeal angles. No significant differences were found between the observers. No systematic deviations for any observer between repeated measurements were detected. Conclusions Measurements of the radiographic hallux angle of the margo medialis pedis are reliable and show high correlation with the metatarsophalangeal angle. Because the hallux valgus angles based on margo medialis pedis measurements were slightly but statistically significantly smaller, these measurements should be considered conservative estimates of the metatarsophalangeal angle. Significant differences between hallux valgus angles based on radiographic and non-radiographic material are unlikely. However this question has to be treated in a second stage in detail. PMID:24751201
Zhuang, Mingna V.; Higham, Timothy E.
2016-01-01
By using adhesion, geckos can move through incredibly challenging habitats. However, continually changing terrain may necessitate modulation of the adhesive apparatus in order to maximize its effectiveness over a range of challenges. Behaviorally modulating how the adhesive system is applied can occur by altering the alignment of the foot relative to the long axis of the body and/or the angles between the digits (interdigital angle). Given the directionality of the adhesive system, geckos likely vary the application of the system via these mechanisms as they run. We quantified 3D movements (using high-speed video) of the day gecko, Phelsuma madagascariensis, running on a range of ecologically relevant inclines (0°, 45°, 90°) and perch diameters (1.5 cm, 10 cm and broad). We measured the instantaneous sum of interdigital angles and foot alignment relative to the body, as well as other kinematic variables, throughout each stride and across treatments. Modulation of foot alignment at 45° and 90° was similar between the forelimb and hind limb, but differed at 0°, suggesting that P. madagascariensis is able to exert an adhesive force using multiple strategies. Both the sum of interdigital angles and alignment in the fore- and hind foot were modulated. Differences in modulation between the limbs are likely related to the underlying morphology. The modulation of interdigital angle and foot alignment suggests that aspects other than the mechanism of adhesion, such as joint morphology, are important for arboreal movement in geckos. Our study of foot usage in arboreal locomotion reveals patterns that may be widespread across pad-bearing lizards. In addition to understanding the constraints exerted by the adhesive apparatus, we highlight how biomechanical traits may respond to the evolution of novel adaptations and morphologies. PMID:27145027
Shultz, Rebecca; Jenkyn, Thomas
2012-01-01
Measuring individual foot joint motions requires a multi-segment foot model, even when the subject is wearing a shoe. Each foot segment must be tracked with at least three skin-mounted markers, but for these markers to be visible to an optical motion capture system holes or 'windows' must be cut into the structure of the shoe. The holes must be sufficiently large avoiding interfering with the markers, but small enough that they do not compromise the shoe's structural integrity. The objective of this study was to determine the maximum size of hole that could be cut into a running shoe upper without significantly compromising its structural integrity or changing the kinematics of the foot within the shoe. Three shoe designs were tested: (1) neutral cushioning, (2) motion control and (3) stability shoes. Holes were cut progressively larger, with four sizes tested in all. Foot joint motions were measured: (1) hindfoot with respect to midfoot in the frontal plane, (2) forefoot twist with respect to midfoot in the frontal plane, (3) the height-to-length ratio of the medial longitudinal arch and (4) the hallux angle with respect to first metatarsal in the sagittal plane. A single subject performed level walking at her preferred pace in each of the three shoes with ten repetitions for each hole size. The largest hole that did not disrupt shoe integrity was an oval of 1.7cm×2.5cm. The smallest shoe deformations were seen with the motion control shoe. The least change in foot joint motion was forefoot twist in both the neutral shoe and stability shoe for any size hole. This study demonstrates that for a hole smaller than this size, optical motion capture with a cluster-based multi-segment foot model is feasible for measure foot in shoe kinematics in vivo. Copyright © 2011. Published by Elsevier Ltd.
Use of a pitch adjustable foot restraint system: Operator strength capability and load requirements
NASA Technical Reports Server (NTRS)
Wilmington, Robert P.; Poliner, Jeffrey; Klute, Glenn K.
1994-01-01
The zero-gravity environment creates a need for a proper human body restraint system to maintain a comfortable posture with less fatigue and to maximize productivity. In addition, restraint systems must be able to meet the loading demands of maintenance and assembly tasks performed on orbit. The shuttle's primary intravehicular astronaut restraint system is currently a foot loop design that attaches to flat surfaces on the shuttle, allowing for varying mounting locations and easy egress and ingress. However, this design does not allow for elevation, pitch, or foot loop length adjustment. Several prototype foot restraint systems are being evaluated for use aboard the space station and the space shuttle. The JSC Anthropometry and Biomechanics Laboratory initiated this study to quantify the maximum axial forces and moments that would be induced on a foot loop type of restraint while operators performed a torque wrench task, also allowing for angling the restraint pitch angle to study yet another effect. Results indicate that the greatest forces into the torque wrench and into the foot restraint system occur while the operator performs an upward effort. This study did not see any significant difference in the operators' force due to pitch orientation. Thus, in a work environment in which hand holds are available, no significant influence of the pitch angle on forces imparted to the restraint system existed.
A comparison of two multisegment foot models in high-and low-arched athletes.
Powell, Douglas W; Williams, D S Blaise; Butler, Robert J
2013-01-01
Malalignment and dysfunction of the foot have been associated with an increased propensity for overuse and traumatic injury in athletes. Several multisegment foot models have been developed to investigate motions in the foot. However, it remains unknown whether the kinematics measured by different multisegment foot models are equivocal. The purpose of the present study is to examine the efficacy of two multisegment foot models in tracking aberrant foot function. Ten high-arched and ten low-arched female athletes walked and ran while ground reaction forces and three-dimensional kinematics were tracked using the Leardini and Oxford multisegment foot models. Ground reaction forces and joint angles were calculated with Visual 3D (C-Motion Inc, Germantown, MD). Repeated-measures analyses of variance were used to analyze peak eversion, time to peak eversion, and eversion excursions. The Leardini model was more sensitive to differences in peak eversion angles than the Oxford model. However, the Oxford model detected differences in eversion excursion values that the Leardini model did not detect. Although both models found differences in frontal plane motion between high- and low-arched athletes, the Leardini multisegment foot model is suggested to be more appropriate as it directly tracks frontal plane midfoot motion during dynamic motion.
Liu, Yang; Gao, Binghong; Li, Jiru; Ma, Zuchang; Sun, Yining
2018-06-07
The aim of this study was to investigate whether changes on foot-stretcher height were associated with characteristics of better rowing performance. Ten male rowers performed a 200 m rowing trial at their racing rate at each of three foot-stretcher heights. A single scull was equipped with an accelerometer to collect boat acceleration, an impeller with embedded magnets to collect boat speed, specially designed gate sensors to collect gate force and angle, and a compact string potentiometer to collect leg drive length. All sensor signals were sampled at 50 Hz. A one-way repeated measures ANOVA showed that raising foot-stretcher position had a significant reduction on total gate angle and leg drive length. However, a raised foot-stretcher position had a deeper negative peak of boat acceleration at the catch, a lower boat fluctuation, a faster leg drive speed, a larger gate force for the port and starboard side separately. This could be attributed to the optimisation of the magnitude and direction of the foot force with a raised foot-stretcher position. Although there was a significant negative influence of a raised foot-stretcher position on two kinematic variables, biomechanical evidence suggested that a raised foot-stretcher position could contribute to the improvement of rowing performance.
Kokubo, Tetsuro; Hashimoto, Takeshi; Suda, Yasunori; Waseda, Akeo; Ikezawa, Hiroko
2017-12-01
Second metatarsophalangeal (MTP) joint dislocation is associated with hallux valgus, and the treatment of complete dislocation can be difficult. The purpose of this study was to radiographically clarify the characteristic foot shape in the presence of second MTP joint dislocation. Weight-bearing foot radiographs of the 268 patients (358 feet) with hallux valgus were examined. They were divided into 2 groups: those with second MTP joint dislocation (study group = 179 feet) and those without dislocation (control group = 179 feet). Parameters measured included the hallux valgus angle (HVA), first-second intermetatarsal angle (IMA), second MTP joint angle, hallux interphalangeal angle (IPA), second metatarsal protrusion distance (MPD), metatarsus adductus angle (MAA), and the second metatarsal declination angle (2MDA). Furthermore, the dislocation group was divided into 3 subgroups according to second toe deviation direction: group M (medial type), group N (neutral type), and group L (lateral type). The IPA and the 2MDA were significantly greater in the study group than in the control group. By multiple comparison analysis, the IMA was greatest in group M and smallest in group L. The IPA was smaller and 2MDA greater in group N than in group L. The HVA and MAA in group L were greatest, and MPD in group L was smallest. The patients with second MTP joint dislocation associated with hallux valgus had greater hallux interphalangeal joint varus and a second metatarsal more inclined than with hallux valgus alone. The second toe deviated in a different direction according to the foot shape. Level III, retrospective comparative study.
An Inverse Kinematic Approach Using Groebner Basis Theory Applied to Gait Cycle Analysis
2013-03-01
stance phase begins with initial contact, heel strike , and ends with toe off. The swing phase begins at toe off and ends with the heel striking the ground...and transition phase (10%). Recall, that the gait cycle begins when the heel strikes the ground of one foot and ends when that same foot strikes the...Validation of Knee Angle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 12 Validation of Ankle Angle
The Shank-to-Vertical-Angle as a parameter to evaluate tuning of Ankle-Foot Orthoses.
Kerkum, Yvette L; Houdijk, Han; Brehm, Merel-Anne; Buizer, Annemieke I; Kessels, Manon L C; Sterk, Arjan; van den Noort, Josien C; Harlaar, Jaap
2015-09-01
The effectiveness of an Ankle-Foot Orthosis footwear combination (AFO-FC) may be partly dependent on the alignment of the ground reaction force with respect to lower limb joint rotation centers, reflected by joint angles and moments. Adjusting (i.e. tuning) the AFO-FC's properties could affect this alignment, which may be guided by monitoring the Shank-to-Vertical-Angle. This study aimed to investigate whether the Shank-to-Vertical-Angle during walking responds to variations in heel height and footplate stiffness, and if this would reflect changes in joint angles and net moments in healthy adults. Ten subjects walked on an instrumented treadmill and performed six trials while walking with bilateral rigid Ankle-Foot Orthoses. The AFO-FC heel height was increased, aiming to impose a Shank-to-Vertical-Angle of 5°, 11° and 20°, and combined with a flexible or stiff footplate. For each trial, the Shank-to-Vertical-Angle, joint flexion-extension angles and net joint moments of the right leg at midstance were averaged over 25 gait cycles. The Shank-to-Vertical-Angle significantly increased with increasing heel height (p<0.001), resulting in an increase in knee flexion angle and internal knee extensor moment (p<0.001). The stiff footplate reduced the effect of heel height on the internal knee extensor moment (p=0.030), while the internal ankle plantar flexion moment increased (p=0.035). Effects of heel height and footplate stiffness on the hip joint were limited. Our results support the potential to use the Shank-to-Vertical-Angle as a parameter to evaluate AFO-FC tuning, as it is responsive to changes in heel height and reflects concomitant changes in the lower limb angles and moments. Copyright © 2015 Elsevier B.V. All rights reserved.
Safaeepour, Zahra; Esteki, Ali; Tabatabai Ghomshe, Farhad; Mousavai, Mohammad E
2014-10-01
In the present study, a new approach was applied to design and develop a viscoelastic ankle-foot prosthesis. The aim was to replicate the intact ankle moment-angle loop in the normal walking speed. The moment-angle loop of intact ankle was divided into four parts, and the appropriate models including two viscoelastic units of spring-damper mechanism were considered to replicate the passive ankle dynamics. The developed prototype was then tested on a healthy subject with the amputee gait simulator. The result showed that prosthetic ankle moment-angle loop was similar to that of intact ankle with the distinct four periods. The findings suggest that the prototype successfully provided the human ankle passive dynamics. Therefore, the viscoelastic units could imitate the four periods of a normal gait. The novel viscoelastic foot prosthesis could provide natural ankle dynamics in a gait cycle. Applying simple but biomechanical approach is suggested in conception of new designs for prosthetic ankle-foot mechanisms. © The International Society for Prosthetics and Orthotics 2014.
Evaluation of changes to foot shape in females 5 years after mastectomy: a case-control study.
Głowacka-Mrotek, Iwona; Sowa, Magdalena; Siedlecki, Zygmunt; Nowikiewicz, Tomasz; Hagner, Wojciech; Zegarski, Wojciech
2017-06-01
The aim of this study was to evaluate changes in foot shape of women 5 years after undergoing breast amputation. Evaluation of foot shape was performed using a non-invasive device for computer analysis of the plantar surface of the foot. Obtained results were compared between feet on the healthy breast side (F1) and on the amputated breast side (F2). 128 women aged 63.60 ± 8.83, 5-6 years after breast amputation were enrolled in this case-control study. Weight bearing on the lower extremity on the amputated breast side (F1) compared with the healthy breast side (F2) showed statistically significant differences (p < 0.01). Patients put more weight onto the healthy breast side. No statistically significant difference was found with regard to F1 and F2 foot length (p = 0.4239), as well as BETA (p = 0.4470) and GAMMA (p = 0.4566) angles. Highly statistically significant differences were noted with respect to foot width, ALPHA angle, and Sztriter-Godunov index-higher values were observed on the healthy breast side (p < 0.001). Highly statistically significant differences were also noted while comparing Clark's angles, higher values being observed on the operated breast side (p < 0.001). Differences in foot shape on the healthy breast side and amputated breast side constitute a long-term negative consequence of mastectomy, and can be caused by unbalanced weight put on feet on the healthy breast side compared to the amputated breast side.
3D Multi-segment foot kinematics in children: A developmental study in typically developing boys.
Deschamps, Kevin; Staes, Filip; Peerlinck, Kathelijne; Van Geet, Christel; Hermans, Cedric; Matricali, Giovanni Arnoldo; Lobet, Sebastien
2017-02-01
The relationship between age and 3D rotations objectivized with multisegment foot models has not been quantified until now. The purpose of this study was therefore to investigate the relationship between age and multi-segment foot kinematics in a cross-sectional database. Barefoot multi-segment foot kinematics of thirty two typically developing boys, aged 6-20 years, were captured with the Rizzoli Multi-segment Foot Model. One-dimensional statistical parametric mapping linear regression was used to examine the relationship between age and 3D inter-segment rotations of the dominant leg during the full gait cycle. Age was significantly correlated with sagittal plane kinematics of the midfoot and the calcaneus-metatarsus inter-segment angle (p<0.0125). Age was also correlated with the transverse plane kinematics of the calcaneus-metatarsus angle (p<0.0001). Gait labs should consider age related differences and variability if optimal decision making is pursued. It remains unclear if this is of interest for all foot models, however, the current study highlights that this is of particular relevance for foot models which incorporate a separate midfoot segment. Copyright © 2016 Elsevier B.V. All rights reserved.
Repeatability of a 3D multi-segment foot model protocol in presence of foot deformities.
Deschamps, Kevin; Staes, Filip; Bruyninckx, Herman; Busschots, Ellen; Matricali, Giovanni A; Spaepen, Pieter; Meyer, Christophe; Desloovere, Kaat
2012-07-01
Repeatability studies on 3D multi-segment foot models (3DMFMs) have mainly considered healthy participants which contrasts with the widespread application of these models to evaluate foot pathologies. The current study aimed at establishing the repeatability of the 3DMFM described by Leardini et al. in presence of foot deformities. Foot kinematics of eight adult participants were analyzed using a repeated-measures design including two therapists with different levels of experience. The inter-trial variability was higher compared to the kinematics of healthy subjects. Consideration of relative angles resulted in the lowest inter-session variability. The absolute 3D rotations between the Sha-Cal and Cal-Met seem to have the lowest variability in both therapists. A general trend towards higher σ(sess)/σ(trial) ratios was observed when the midfoot was involved. The current study indicates that not only relative 3D rotations and planar angles can be measured consistently in patients, also a number of absolute parameters can be consistently measured serving as basis for the decision making process. Copyright © 2012 Elsevier B.V. All rights reserved.
Interaction effects of stride angle and strike pattern on running economy.
Santos-Concejero, J; Tam, N; Granados, C; Irazusta, J; Bidaurrazaga-Letona, I; Zabala-Lili, J; Gil, S M
2014-12-01
This study aimed to investigate the relationship between stride angle and running economy (RE) in athletes with different foot strike patterns. 30 male runners completed 4 min running stages on a treadmill at different velocities. During the test, biomechanical variables such as stride angle, swing time, contact time, stride length and frequency were recorded using an optical measurement system. Their foot strike pattern was determined, and VO2 at velocities below the lactate threshold were measured to calculate RE. Midfoot/forefoot strikers had better RE than rearfoot strikers (201.5±5.6 ml · kg(-1) · km(-1) vs. 213.5±4.2 ml · kg(-1) · km(-1)respectively; p=0.019). Additionally, midfoot/fore-foot strikers presented higher stride angles than rearfoot strikers (p=0.043). Linear modelling analysis showed that stride angle is closely related to RE (r=0.62, p<0.001) and that the effect of stride angle on RE was different in the 2 groups. From an arbitrary value of 4°, a rearfoot strike pattern is likely to be more economical, whereas at any lower degree, the midfoot/forefoot strike pattern appears to be more desirable. A biomechanical running technique characterised by high stride angles and a midfoot/forefoot strike pattern is advantageous for a better RE. Athletes may find stride angle useful for improving RE. © Georg Thieme Verlag KG Stuttgart · New York.
Christopher, R Carcia; Drouin, Joshua M; Houglum, Peggy A
2006-01-01
Non-contact anterior cruciate ligament (ACL) injuries in female athletes remain prevalent. Athletes with excessive foot pronation have been identified to be at greater risk for non-contact ACL injury. Excessive foot pronation has been linked to increased medial tibial rotation. Increased medial tibial rotation heightens ACL strain and has been observed at or near the time of ACL injury. Foot orthotics have been shown to decrease medial tibial rotation during walking and running tasks. The effect of a foot orthotic on activities that simulate a non-contact ACL injury mechanism (i.e. landing) however is unknown. Therefore, the objective of this study was to determine whether a foot orthotic was capable of altering transverse plane lower extremity kinematics in female athletes during landing. Twenty uninjured collegiate female athletes participating in the sports of basketball, soccer or volleyball with pes planus volunteered. Utilizing a repeated measures counterbalanced design, subjects completed two landing tasks with and without a foot orthotic using standardized footwear. The prefabricated orthotic had a rigid shell and a 6 extrinsic rear-foot varus post. Dependent measures included initial contact angle, peak angle, excursion and time to peak angle for both the tibia and femur. Statistical analysis suggested that the selected foot orthosis had little influence over lower extremity transverse plane kinematics. Several factors including: the limitation of a static measure to predict dynamic movement, inter-subject variability and the physical characteristics of the orthotic device likely account for the results. Future research should examine the influence of different types of foot orthotics not only on lower extremity kinematics but also tibiofemoral kinetics. Key PointsLower extremity transverse plane kinematics in female athletes during a landing task exhibit substantial variability.A rigid prefabricated foot orthotic does not significantly alter transverse plane lower extremity kinematics in female athletes with a navicular drop of at least 8mm.Additional study is necessary before firm conclusions regarding the influence of an orthotic device on lower extremity kinematics, kinetics, neuromuscular control and ultimately injury rates can be made.
Foot mechanics during the first six years of independent walking.
Samson, William; Dohin, Bruno; Desroches, Guillaume; Chaverot, Jean-Luc; Dumas, Raphaël; Cheze, Laurence
2011-04-29
Recognition of the changes during gait that occur normally as a part of growth is essential to prevent mislabeling those changes from adult gait as evidence of gait pathology. Currently, in the literature, the definition of a mature age for ankle joint dynamics is controversial (i.e., between 5 and 10 years). Moreover, the mature age of the metatarsophalangeal (MP) joint, which is essential for the functioning of the foot, has not been defined in the literature. Thus, the objective of the present study explored foot mechanics (ankle and MP joints) in young children to define a mature age of foot function. Forty-two healthy children between 1 and 6 years of age and eight adults were measured during gait. The ground reaction force (GRF), the MP and ankle joint angles, moments, powers, and 3D angles between the joint moment and the joint angular velocity vectors (3D angle α(M.ω)) were processed and compared between four age groups (2, 3.5, 5 and adults). Based on statistical analysis, the MP joint biomechanical parameters were similar between children (older than 2 years) and adults, hinting at a quick maturation of this joint mechanics. The ankle joint parameters and the GRFs (except for the frontal plane) showed an adult-like pattern in 5-year-old children. Some ankle joint parameters, such as the joint power and the 3D angle α(M.ω) still evolved significantly until 3.5 years. Based on these results, it would appear that foot maturation during gait is fully achieved at 5 years. Copyright © 2011 Elsevier Ltd. All rights reserved.
Dullaert, K; Hagen, J; Klos, K; Gueorguiev, B; Lenz, M; Richards, R G; Simons, P
2016-05-01
Subtle hypermobility of the first tarsometatarsal joint can occur concomitantly with other pathologies and may be difficult to diagnose. Peroneus Longus muscle might influence stability of this joint. Collapse of the medial longitudinal arch is common in flatfoot deformity and the muscle might also play a role in correcting Meary's angle. A radiolucent frame was used to simulate weightbearing during CT examination. Eight pairs fresh-frozen lower legs were imaged in neutral position under non-weightbearing (75N), weightbearing (700N) and with 15kg weights hung from Peroneus Longus tendon. Measurements included first metatarsal rotation, intermetatarsal angle, first tarsometatarsal joint subluxation and Meary's angle. Weightbearing significantly increased Meary's angle and significantly decreased first tarsometatarsal joint subluxation (both P<0.01). Pulling Peroneus Longus tendon significantly increased first metatarsal rotation (P<0.01), significantly decreased the intermetatarsal angle (P<0.01) and increased non-significantly Meary's angle (P=0.52). A considerable effect weightbearing has on the medial longitudinal arch and first tarsometatarsal joint was observed. Pulling Peroneus Longus tendon improved first metatarsal subluxation but increased its rotation. The study calls into question the importance of this tendon in maintaining the medial longitudinal arch and raises concerns about rotational deformity of the first metatarsal following hallux valgus correction without first tarsometatarsal arthrodesis. Study outcomes will provide more insight in foot pathology. Weightbearing affects anatomy of the foot. No reliable information is available concerning the influence of the Peroneus muscle. This study investigates the influence of weightbearing and the impact the Peroneus muscle on the anatomy of the foot. Copyright © 2016. Published by Elsevier Ltd.
Chern, Jen-Suh; Kao, Chia-Chi; Lai, Po-Lian; Lung, Chi-Wen; Chen, Wen-Jer
2014-01-01
Center of pressure (CoP) progression during level walking in subjects with Adolescents Idiopathic Scoliosis (AIS) was measured. Participants were divided into three groups according to scoliosis severity. CoP progression among groups was compared quantitatively and qualitatively. The results showed that scoliosis severity affects CoP progression significantly in the hind-foot and forefoot areas. This result indicated that spine alignment might affect the control of heel, ankle and toe rockers in the ankle-foot complex. The effects of scoliosis severity is mainly on the CoP of right foot plantar surface, indicating asymmetrical influence of IS on bilateral lower limb coordination during walking. These results might contribute to musculoskeletal complains over the apparatus within trunk-foot in the later lives of this population.
NASA Technical Reports Server (NTRS)
Bradley, D.; Buchholz, R. E.
1971-01-01
A 0.015 scale model of a modified version of the MDAC space shuttle booster was tested in the Naval Ship Research and Development Center 7 x 10 foot transonic wind tunnel, to obtain force, static stability, and control effectiveness data. Data were obtained for a cruise Mach Number of 0.38, altitude of 10,000 ft, and Reynolds Number per foot of approximately 2 x one million. The model was tested through an angle of attack range of -4 deg to 15 deg at zero degree angle of sideslip, and at an angle of sideslip range of -6 deg to 6 deg at fixed angles of attack of 0 deg, 6 deg, and 15 deg. Other test variables were elevon deflections, canard deflections, aileron deflections, rudder deflections, wing dihedral angle, canard incidence angle, wing incidence angle, canard position, wing position, wing and canard control flap size and dorsal fin size.
16 CFR Table 2 to Part 1512 - Minimum Candlepower per Incident Foot-Candle for Clear Reflector 1
Code of Federal Regulations, 2011 CFR
2011-01-01
... 16 Commercial Practices 2 2011-01-01 2011-01-01 false Minimum Candlepower per Incident Foot-Candle for Clear Reflector 1 2 Table 2 to Part 1512 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION... 1512—Minimum Candlepower per Incident Foot-Candle for Clear Reflector 1 Observation angle Front, rear...
MacLellan, M J; Catavitello, G; Ivanenko, Y P; Lacquaniti, F
2017-11-01
Habitual quadrupeds have been shown to display a planar covariance of segment elevation angle waveforms in the fore and hind limbs during many forms of locomotion. The purpose of the current study was to determine if humans generate similar patterns in the upper and lower limbs during hand-foot crawling. Nine healthy young adults performed hand-foot crawling on a treadmill at speeds of 1, 2, and 3 km/h. A principal component analysis (PCA) was applied to the segment elevation angle waveforms for the upper (upper arm, lower arm, and hand) and lower (thigh, shank, and foot) limbs separately. The planarity of the elevation angle waveforms was determined using the sum of the variance explained by the first two PCs and the orientation of the covariance plane was quantified using the direction cosines of the eigenvector orthogonal to the plane, projected upon each of the segmental semi-axes. Results showed that planarity of segment elevation angles was maintained in the upper and lower limbs (explained variance >97%), although a slight decrease was present in the upper limb when crawling at 3 km/h. The orientation of the covariance plane was highly limb-specific, consistent with animal studies and possibly related to the functional neural control differences between the upper and lower limbs. These results may suggest that the motor patterns stored in the central nervous system for quadrupedal locomotion may be retained through evolution and may still be exploited when humans perform such tasks.
Park, Chul Hyun; Lee, Woo-Chun
We compared the results of proximal chevron osteotomy and double metatarsal osteotomy for hallux valgus with an increased distal metatarsal articular angle (DMAA). From October 2008 to December 2012, first metatarsal osteotomies were performed in 64 patients (69 feet) with symptomatic hallux valgus associated with an increased DMAA. Proximal chevron with Akin osteotomy and lateral soft tissue release was performed in 46 feet (PCO group); double metatarsal osteotomy and Akin osteotomy without lateral soft tissue release was performed in 23 feet (DMO group). Clinical assessments were performed using the American Orthopaedic Foot and Ankle Society (AOFAS) scale and visual analog scale (VAS). The hallux valgus angles, intermetatarsal angles, sesamoid positions, metatarsus adductus angles, and DMAAs were compared at different postoperative times. Postoperative shortening of first the metatarsal and complications were compared. The mean AOFAS scale and VAS scores showed significant improvement in both groups after surgery; however, no significant difference was observed between the 2 groups. The immediate postoperative hallux valgus angle and sesamoid position were significantly larger in DMO group; however, no intergroup difference was observed at the last follow-up visit, with the hallux valgus angle gradually increasing in the PCO group. The postoperative DMAA was significantly smaller in the DMO group. The mean shortening of the first metatarsal after surgery was significantly larger in the DMO group than in the PCO group. Transfer metatarsalgia developed in 1 foot (2.2%) in the PCO group and 2 feet (8.7%) in the DMO group. Partial avascular necrosis of the metatarsal head with advanced arthritis of the first metatarsophalangeal joint developed in 1 foot (4.3%) in the DMO group. In conclusion, no differences in the clinical and radiographic results were observed between the 2 groups for hallux valgus deformity with an increased DMAA. Copyright © 2017 The American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.
Code of Federal Regulations, 2011 CFR
2011-07-01
...) When a fixed flat tread accommodation ladder is used, and the angle is low enough to require employees... serious injury from falls to a lower level. (f) If the foot of a gangway is more than one foot (.30 m...
Gatt, Alfred; Chockalingam, Nachiappan
2012-06-01
Trials investigating ankle joint measurement normally apply a known moment. Maximum ankle angle is affected by foot posture and stretching characteristics of the calf muscles. To investigate whether consistent maximum ankle angles could be achieved without applying a constant moment to all subjects, and whether short, repetitive stretching of the calf muscle tendon unit would produce a difference in the maximum ankle angle. Passive dorsiflexion in 14 healthy participants was captured using an optoelectronic motion analysis system, with the foot placed in 3 postures. The maximum ankle angles for both the neutral and supinated positions did not differ significantly. In general, the majority of subjects (92.8%) showed no increase in the maximum ankle dorsiflexion angle following repetitive brief passive stretching. Only one subject exhibited a significant increase in maximum ankle angle at the neutral position. Since the range of motion of the ankle joint is clearly determined by other physical factors, the maximum ankle dorsiflexion angle can be assessed at both neutral and supinated positions without moment being controlled. Copyright © 2011 Elsevier Ltd. All rights reserved.
Dynamic foot function and morphology in elite rugby league athletes of different ethnicity.
Gurney, Jason K; Kersting, Uwe G; Rosenbaum, Dieter
2009-05-01
It has long been assumed that foot function and morphology differ between ethnicities. However, quantitative research proving or disproving this relationship is sparse. As a starting point, the objective of this study was to investigate the plantar loading characteristics and foot geometry of athletes from three ethnicities, being Caucasian, Maori and Pacific Islanders. Four plantar pressure parameters were compared in 28 male elite rugby league players using an EMED-AT plantar pressure distribution platform [Novel GmbH, Munich, Germany] and the five-step method. Foot geometry measures were also taken, including arch index, coefficient of spreading, hallux angle and sub-arch angle. Five trials were collected per foot at a self-selected speed. It was found that Caucasian and Maori subjects had a relatively wider forefoot than the Pacific Island subjects; however the Pacific Islanders' foot was found to be wider than both these ethnicities in absolute terms. While Caucasian subjects loaded the toes to a much greater extent than the Maori and Pacific Island subjects, the latter demonstrated a greater loading of the mid and forefoot regions. Pacific Island subjects revealed a significantly more pronounced hallux valgus angle as compared to the Caucasian and Maori subjects. The results of this study may be relevant for/should be taken into consideration in footwear design issues, where allowances need to be made during the design process for anatomical differences between ethnicities. However these observations cannot be generalised to whole ethnic populations, and further research is required on non-athletes to build on the current research findings.
Functional Locomotor Consequences of Uneven Forefeet for Trot Symmetry in Individual Riding Horses
Wiggers, Nathan; Nauwelaerts, Sandra L. P.; Hobbs, Sarah Jane; Bool, Sophie; Wolschrijn, Claudia F.; Back, Willem
2015-01-01
Left-right symmetrical distal limb conformation can be an important prerequisite for a successful performance, and it is often hypothesized that asymmetric or uneven feet are important enhancing factors for the development of lameness. On a population level, it has been demonstrated that uneven footed horses are retiring earlier from elite level competition, but the biomechanical consequences are not yet known. The objectives of this study were to compare the functional locomotor asymmetries of horses with uneven to those with even feet. Hoof kinetics and distal limb kinematics were collected from horses (n = 34) at trot. Dorsal hoof wall angle was used to classify horses as even or uneven (<1.5 and >1.5° difference between forefeet respectively) and individual feet as flat (<50°), medium (between 50° and 55°) or upright (>55°). Functional kinetic parameters were compared between even and uneven forefeet using MANOVA followed by ANOVA. The relative influences of differences in hoof angle between the forefeet and of absolute hoof angle on functional parameters were analysed using multiple regression analysis (P<0.05). In horses with uneven feet, the side with the flatter foot showed a significantly larger maximal horizontal braking and vertical ground reaction force, a larger vertical fetlock displacement and a suppler fetlock spring. The foot with a steeper hoof angle was linearly correlated with an earlier braking-propulsion transition. The conformational differences between both forefeet were more important for loading characteristics than the individual foot conformation of each individual horse. The differences in vertical force and braking force between uneven forefeet could imply either an asymmetrical loading pattern without a pathological component or a subclinical lameness as a result of a pathological development in the steeper foot. PMID:25646752
Sinitski, Emily H; Hansen, Andrew H; Wilken, Jason M
2012-02-02
Unilateral lower limb prosthesis users display temporal, kinematic, and kinetic asymmetries between limbs while ascending and descending stairs. These asymmetries are due, in part, to the inability of current prosthetic devices to effectively mimic normal ankle function. The purpose of this study was to provide a comprehensive set of biomechanical data for able-bodied and unilateral transtibial amputee (TTA) ankle-foot systems for level-ground (LG), stair ascent (SA), and stair descent (SD), and to characterize deviations from normal performance associated with prosthesis use. Ankle joint kinematics, kinetics, torque-angle curves, and effective shapes were calculated for twelve able-bodied individuals and twelve individuals with TTA. The data from this study demonstrated the prosthetic limb can more effectively mimic the range of motion and power output of a normal ankle-foot during LG compared to SA and SD. There were larger differences between the prosthetic and able-bodied limbs during SA and SD, most evident in the torque-angle curves and effective shapes. These data can be used by persons designing ankle-foot prostheses and provide comparative data for assessment of future ankle-foot prosthesis designs. Published by Elsevier Ltd.
Foot Morphological Difference between Habitually Shod and Unshod Runners.
Shu, Yang; Mei, Qichang; Fernandez, Justin; Li, Zhiyong; Feng, Neng; Gu, Yaodong
2015-01-01
Foot morphology and function has received increasing attention from both biomechanics researchers and footwear manufacturers. In this study, 168 habitually unshod runners (90 males whose age, weight & height were 23±2.4 years, 66±7.1 kg & 1.68±0.13 m and 78 females whose age, weight & height were 22±1.8 years, 55±4.7 kg & 1.6±0.11 m) (Indians) and 196 shod runners (130 males whose age, weight & height were 24±2.6 years, 66±8.2 kg & 1.72±0.18 m and 66 females whose age, weight & height were 23±1.5 years, 54±5.6 kg & 1.62±0.15 m) (Chinese) participated in a foot scanning test using the easy-foot-scan (a three-dimensional foot scanning system) to obtain 3D foot surface data and 2D footprint imaging. Foot length, foot width, hallux angle and minimal distance from hallux to second toe were calculated to analyze foot morphological differences. This study found that significant differences exist between groups (shod Chinese and unshod Indians) for foot length (female p = 0.001), width (female p = 0.001), hallux angle (male and female p = 0.001) and the minimal distance (male and female p = 0.001) from hallux to second toe. This study suggests that significant differences in morphology between different ethnicities could be considered for future investigation of locomotion biomechanics characteristics between ethnicities and inform last shape and design so as to reduce injury risks and poor performance from mal-fit shoes.
Foot Morphological Difference between Habitually Shod and Unshod Runners
Shu, Yang; Mei, Qichang; Fernandez, Justin; Li, Zhiyong; Feng, Neng; Gu, Yaodong
2015-01-01
Foot morphology and function has received increasing attention from both biomechanics researchers and footwear manufacturers. In this study, 168 habitually unshod runners (90 males whose age, weight & height were 23±2.4years, 66±7.1kg & 1.68±0.13m and 78 females whose age, weight & height were 22±1.8years, 55±4.7kg & 1.6±0.11m) (Indians) and 196 shod runners (130 males whose age, weight & height were 24±2.6years, 66±8.2kg & 1.72±0.18m and 66 females whose age, weight & height were 23±1.5years, 54±5.6kg & 1.62±0.15m)(Chinese) participated in a foot scanning test using the easy-foot-scan (a three-dimensional foot scanning system) to obtain 3D foot surface data and 2D footprint imaging. Foot length, foot width, hallux angle and minimal distance from hallux to second toe were calculated to analyze foot morphological differences. This study found that significant differences exist between groups (shod Chinese and unshod Indians) for foot length (female p = 0.001), width (female p = 0.001), hallux angle (male and female p = 0.001) and the minimal distance (male and female p = 0.001) from hallux to second toe. This study suggests that significant differences in morphology between different ethnicities could be considered for future investigation of locomotion biomechanics characteristics between ethnicities and inform last shape and design so as to reduce injury risks and poor performance from mal-fit shoes. PMID:26148059
A model to calculate the progression of the centre of pressure under the foot during gait analysis.
Louey, Melissa Gar Yee; Mudge, Anita; Wojciechowski, Elizabeth; Sangeux, Morgan
2017-09-01
Pedobarography and the centre of pressure (COP) progression is useful to understand foot function. Pedobarography is often unavailable in gait laboratories or completed asynchronously to kinematic and kinetic data collection. This paper presents a model that allows calculation of COP progression synchronously using force plate data. The model is an adjunct to Plug-In-Gait and was applied to 49 typically developing children to create reference COP data. COP progressions were noted to spend 8% of stance behind the ankle joint centre, traverse lateral of the longitudinal axis of the foot through the midfoot for 76% of stance and finishing past the second metatarsal head on the medial side for 16% of stance. It is hoped the model will bridge the information gap for gait laboratories lacking pedobarography during foot assessments and will open up the possibility of retrospective research into COP progression based indices on kinematic data. Copyright © 2017 Elsevier B.V. All rights reserved.
NASA Technical Reports Server (NTRS)
Marroquin, J.
1985-01-01
An experimental investigation was performed in the NASA/Ames Research Center 3.5-foot Hypersonic Wind Tunnel to obtain supersonic heat-distribution data in areas between the orbiter and external tank using phase-change paint techniques. The tests used Novamide SSV Model 56-OTS in the first and second-stage ascent configurations. Data were obtained at a nominal Mach number of 5.3 and a Reynolds number per foot of 5 x 10 to the 6th power with angles of attack of 0 deg, +/- 5 deg, and sideslip angles of 0 deg and +/- 5 deg.
NASA Astrophysics Data System (ADS)
Lenhart, Joseph L.; Fischer, Daniel; Sambasivan, Sharadha; Lin, Eric K.; Wu, Wen-Li; Guerrero, Douglas J.; Wang, Yubao; Puligadda, Rama
2007-02-01
Interactions between a bottom anti-reflective coating (BARC) and a photoresist can critically impact lithographic patterns. For example, a lithographic pattern can shrink or spread near a BARC interface, a process called undercutting or footing respectively, due to incompatibility between the two materials. Experiments were conducted on two industrial BARC coatings in an effort to determine the impact of BARC surface chemistry on the footing and undercutting phenomena. The BARC coatings were characterized by near edge X-ray absorption fine structure (NEXAFS), contact angle measurements, and neutron and X-ray reflectivity. Contact angle measurement using a variety of fluids showed that the fluid contact angles were independent of the type of BARC coating or the BARC processing temperature. NEXAFS measurements showed that the surface chemistry of each BARC was also independent of the processing temperature. These results suggest that acid-base interactions at the BARC-resist interface are not the cause of the footing-undercutting phenomena encountered in lithographic patterns.
NASA Technical Reports Server (NTRS)
Johnson, J. D.; Braddock, W. F.
1975-01-01
A force test of a 2.112 percent scale Space Shuttle Solid Rocket Booster (SRB), MSFC Model 454, was conducted in test section no. 2 of the Unitary Plan Wind Tunnel. Sixteen (16) runs (pitch polars) were performed over an angle of attack range from 144 through 179 degrees. Test Mach numbers were 2.30, 2.70, 2.96, 3.48, 4.00 and 4.63. The first three Mach numbers had a test Reynolds number of 1.5 million per foot. The remaining three were at 2.0 million per foot. The model was tested in the following configurations: (1) SRB without external protuberances, and (2) SRB with an electrical tunnel and a SRB/ET thrust attachment structure. Schlieren photographs were taken during the testing of the first configuration. The second configuration was tested at roll angles of 45, 90, and 135 degrees.
NASA Technical Reports Server (NTRS)
Hamilton, T.
1972-01-01
Experimental aerodynamic investigations were conducted in the 14-inch trisonic wind tunnel during early February 1972 on a 0.00340 scale model of the 33-foot diameter space shuttle pump fed booster configuration. The basic configuration tested was a 40-deg cone/cylinder. Six component aerodynamic force and moment data were recorded over a Mach number range from 0.6 to 5.0, angles-of-attack from 50 to 90 deg at 0 deg sideslip and over a sideslip range from -10 to +10 deg at 60 and 80 deg angles-of-attack. Primary configuration variables were fin area and body cutout size.
Chen, Wen-Ming; Lee, Sung-Jae; Lee, Peter Vee Sin
2014-12-01
Material properties of the plantar soft tissue have not been well quantified in vivo (i.e., from life subjects) nor for areas other than the heel pad. This study explored an in vivo investigation of the plantar soft tissue material behavior under the metatarsal head (MTH). We used a novel device collecting indentation data at controlled metatarsophalangeal joint angles. Combined with inverse analysis, tissues׳ joint-angle dependent material properties were identified. The results showed that the soft tissue under MTH exhibited joint-angle dependent material responses, and the computed parameters using the Ogden material model were 51.3% and 30.9% larger in the dorsiflexed than in the neutral positions, respectively. Using derived parameters in subject-specific foot finite element models revealed only those models that used tissues׳ joint-dependent responses could reproduce the known plantar pressure pattern under the MTH. It is suggested that, to further improve specificity of the personalized foot finite element models, quantitative mechanical properties of the tissue inclusive of the effects of metatarsophalangeal joint dorsiflexion are needed. Copyright © 2014 Elsevier Ltd. All rights reserved.
Bowersox prepares for the FOOT experiment in Destiny during Expedition Six
2003-02-07
ISS006-E-25010 (7 February 2003) --- Astronaut Kenneth D. Bowersox, Expedition Six mission commander, conducts a Foot/Ground Reaction Forces During Spaceflight (FOOT) Electromyography (EMG) calibration at the Human Research Facility (HRF) rack in the Destiny laboratory on the International Space Station (ISS). This experiment determines the change in joint angles (muscle activity) of the ankle, knee, and hip.
NASA Technical Reports Server (NTRS)
Kingsland, R. B.
1976-01-01
The results of wind tunnel tests conducted on a 0.010-scale version of the Vehicle 3 Space Shuttle Configuration were presented. Pressure measurements were made on the launch configuration, orbiter alone, external tank alone, and solid rocket booster alone, to provide heat transfer pressure data. The tests were conducted for a Mach number range from 2.36 to 4.6 and Reynolds number range from 1.2 to 5 million per foot. The model was tested at angles of attack from -10 deg to 20 deg for a sideslip angle range from -5 deg to +5 deg and at sideslip angles from -5 deg to 48 deg for 0 deg angle of attack.
Shultz, Sandra J; Nguyen, Anh-Dung; Schmitz, Randy J
2008-03-01
Descriptive, cross-sectional. We compared lower extremity anatomical characteristics in males and females between different maturation groups. Sex differences have been observed in lower extremity anatomical characteristics. While the reasons contributing to these sex differences in adults are unknown, there is evidence that anatomy and posture change considerably during growth and development. One hundred seventy-three young athletes (age range, 9-18 years) were assessed for stage of maturation and placed into 1 of 3 groups, according to Tanners stages 1 and 2 (MatGrp1), 3 and 4 (MatGrp2), and 5 (MatGrp3). Participants were measured for pelvic angle, hip anteversion, quadriceps angle, tibiofemoral angle, femur length, tibial length, genu recurvatum, tibial torsion, navicular drop, general joint laxity, and anterior knee laxity. Data were compared by sex and maturation group. When comparing maturation groups, limb length, pelvic angle, and tibial torsion increased with maturation, and anterior knee laxity, genu recurvatum, tibiofemoral angle, and foot pronation decreased with maturation. Females had greater general joint laxity, hip anteversion, and tibiofemoral angles, and shorter femur and tibial lengths than males, regardless of maturation group. Maturational changes in knee laxity and quadriceps angles were sex dependent. We observed a general change of posture with maturation that began with greater knee valgus, knee recurvatum, and foot pronation in MatGrp1, then moved toward a relative straightening and external rotation of the knee, and supination of the foot in later maturation groups. While the majority of the measures changed similarly in males and females across maturation groups, decreases in quadriceps angles and anterior knee laxity were greater in males compared to females, and females were observed to have a more inwardly rotated hip and valgus knee posture, compared to males, particularly in later maturation groups.
Chimpanzee ankle and foot joint kinematics: Arboreal versus terrestrial locomotion.
Holowka, Nicholas B; O'Neill, Matthew C; Thompson, Nathan E; Demes, Brigitte
2017-09-01
Many aspects of chimpanzee ankle and midfoot joint morphology are believed to reflect adaptations for arboreal locomotion. However, terrestrial travel also constitutes a significant component of chimpanzee locomotion, complicating functional interpretations of chimpanzee and fossil hominin foot morphology. Here we tested hypotheses of foot motion and, in keeping with general assumptions, we predicted that chimpanzees would use greater ankle and midfoot joint ranges of motion during travel on arboreal supports than on the ground. We used a high-speed motion capture system to measure three-dimensional kinematics of the ankle and midfoot joints in two male chimpanzees during three locomotor modes: terrestrial quadrupedalism on a flat runway, arboreal quadrupedalism on a horizontally oriented tree trunk, and climbing on a vertically oriented tree trunk. Chimpanzees used relatively high ankle joint dorsiflexion angles during all three locomotor modes, although dorsiflexion was greatest in arboreal modes. They used higher subtalar joint coronal plane ranges of motion during terrestrial and arboreal quadrupedalism than during climbing, due in part to their use of high eversion angles in the former. Finally, they used high midfoot inversion angles during arboreal locomotor modes, but used similar midfoot sagittal plane kinematics across all locomotor modes. The results indicate that chimpanzees use large ranges of motion at their various ankle and midfoot joints during both terrestrial and arboreal locomotion. Therefore, we argue that chimpanzee foot anatomy enables a versatile locomotor repertoire, and urge caution when using foot joint morphology to reconstruct arboreal behavior in fossil hominins. © 2017 Wiley Periodicals, Inc.
Effect of excessive body weight on foot arch changes in preschoolers a 2-year follow-up study.
Jankowicz-Szymanska, Agnieszka; Mikolajczyk, Edyta
2015-07-01
A stable standing posture, and effective and aesthetic gait, depend heavily on correct anatomical construction of the feet, thanks to which they can play their important role. The shape and height of the foot arches are already formed in the preschool and early school years; therefore, abnormalities and disorders in children's feet, and correlations between foot formation and somatic build, are still crucial and interesting issues for orthopedists, pediatricians, physiotherapists, and podiatrists. This study deals with changes in the height of the longitudinal and transverse arches of the foot in 4- to 6-year-old children. A total of 102 boys and 105 girls took part in a 24-month study in which their body weight, height, body mass index, and Clarke's and gamma angles were measured. The analysis also focused on correlations among sex, nutritional status, and changes in foot arch height. It was discovered that sex did not considerably affect Clarke's and gamma angle values. However, it was found that between ages 4 and 6 years, the proportion of overweight and obese boys and girls increased, and the medial longitudinal arch of the foot had a tendency to collapse in those with excessive body weight. The effect of nutritional status on the transverse arch of the foot is rather dubious. In light of these findings, therapeutic programs for preventing foot deformities in children should also focus on body weight control.
A clinically applicable six-segmented foot model.
De Mits, Sophie; Segers, Veerle; Woodburn, Jim; Elewaut, Dirk; De Clercq, Dirk; Roosen, Philip
2012-04-01
We describe a multi-segmented foot model comprising lower leg, rearfoot, midfoot, lateral forefoot, medial forefoot, and hallux for routine use in a clinical setting. The Ghent Foot Model describes the kinematic patterns of functional units of the foot, especially the midfoot, to investigate patient populations where midfoot deformation or dysfunction is an important feature, for example, rheumatoid arthritis patients. Data were obtained from surface markers by a 6 camera motion capture system at 500 Hz. Ten healthy subjects walked barefoot along a 12 m walkway at self-selected speed. Joint angles (rearfoot to shank, midfoot to rearfoot, lateral and medial forefoot to midfoot, and hallux to medial forefoot) in the sagittal, frontal, and transverse plane are reported according to anatomically based reference frames. These angles were calculated and reported during the foot rollover phases in stance, detected by synchronized plantar pressure measurements. Repeated measurements of each subject revealed low intra-subject variability, varying between 0.7° and 2.3° for the minimum values, between 0.5° and 2.1° for the maximum values, and between 0.8° and 5.8° for the ROM. The described movement patterns were repeatable and consistent with biomechanical and clinical knowledge. As such, the Ghent Foot model permits intersegment, in vivo motion measurement of the foot, which is crucial for both clinical and research applications. Copyright © 2011 Orthopaedic Research Society.
Singer, Madeline L.; Kobayashi, Toshiki; Lincoln, Lucas S.; Orendurff, Michael S.; Foreman, K. Bo
2014-01-01
Background Stiffness of an ankle-foot orthosis plays an important role in improving gait in patients with a history of stroke. To address this, the aim of this case series study was to determine the effect of increasing plantarflexion stiffness of an ankle-foot orthosis on the sagittal ankle and knee joint angle and moment during the first and second rockers of gait. Methods Gait data were collected in 5 subjects with stroke at a self-selected walking speed under two plantarflexion stiffness conditions (0.4 Nm/deg and 1.3 Nm/deg) using a stiffness-adjustable experimental ankle-foot orthosis on a Bertec split-belt fully instrumented treadmill in a 3-dimensional motion analysis laboratory. Findings By increasing the plantarflexion stiffness of the ankle-foot orthosis, peak plantarfexion angle of the ankle was reduced and peak dorsiflexion moment was generally increased in the first rocker as hypothesized. Two subjects demonstrated increases in both peak knee flexion angle and peak knee extension moment in the second rocker as hypothesized. The two subjects exhibited minimum contractility during active plantarflexion, while the other three subjects could actively plantarflex their ankle joint. Interpretation It was suggested that those with the decreased ability to actively plantarflex their ankle could not overcome excessive plantarflexion stiffness at initial contact of gait, and as a result exhibited compensation strategies at the knee joint. Providing excessively stiff ankle-foot orthoses might put added stress on the extensor muscles of the knee joint, potentially creating fatigue and future pathologies in some patients with stroke. PMID:25241248
Foot and ankle function after tibial overlengthening.
Emara, Khaled M; Diab, Ramy Ahmed; El Ghazali, Sherif; Farouk, Amr; El Kersh, Mohamed Ahmed
2014-01-01
Lengthening the tibia more than 25% of its original length can be indicated for proximal femoral deficiency, poliomyelitis, or femoral infected nonunion. Such lengthening of the tibia can adversely affect the ankle or foot shape and function. The present study aimed to assess the effect of tibial lengthening of more than 25% of its original length on the foot and ankle shape and function compared with the preoperative condition. This was a retrospective study of 13 children with severe proximal focal femoral deficiency, Aitken classification type D, who had undergone limb lengthening from June 2000 to June 2008 using Ilizarov external fixators. The techniques used in tibial lengthening included lengthening without intramedullary rodding and lengthening over a nail. The foot assessment was done preoperatively, at fixator removal, and then annually for 3 years, documenting the range of motion and deformity of the ankle and subtalar joints and big toe and the navicular height, calcaneal pitch angle, and talo-first metatarsal angle. At fixator removal, all cases showed equinocavovarus deformity, with decreased ankle, subtalar, and big toe motion. The mean American Orthopedic Foot and Ankle Society score was significantly reduced. During follow-up, the range of motion, foot deformity, and American Orthopedic Foot and Ankle Society score improved, reaching nearly to the preoperative condition by 2 years of follow-up. The results of our study have shown that tibial overlengthening has an adverse effect on foot and ankle function. This effect was reversible in the patients included in the present study. Lengthening of more than 25% can be safely done after careful discussion with the patients and their families about the probable effects of lengthening on foot and ankle function. Copyright © 2014 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.
Relation of channel stability to scour at highway bridges over waterways in Maryland
Doheny, Edward J.; ,
1993-01-01
Data from assessments of channel stability and observed-scour conditions at 876 highway bridges over Maryland waterways were entered into a database. Relations were found to exist among specific, deterministic variables and observed-scour and debris conditions. Relations were investigated between (1) high-flow angle of attack and pier- and abutment-footing exposure, (2)abutment location and abutment-footing exposure, (3) type of bed material and pier-footing exposure, (4) tree cover on channel banks and mass wasting of the channel banks, and (5) land use near the bridge and the presence of debris blockage at the bridge opening. The results of the investigation indicate the following: (1) The number of pier and abutment-footing exposures increased for increasing high-flow angles of attack, (2) the number of abutment-footing exposures increased for abutments that protrude into the channel, (3) pier-footing exposures were most common for bridges over streams with channel beds of gravel, (4) mass wasting of channel banks with tree cover of 50 percent or greater near the bridge was less than mass wasting of channel banks with tree cover of less than 50 percent near the bridge, and (5) bridges blockage than bridge in row crop and swamp basins.
Powell, Douglas W; Long, Benjamin; Milner, Clare E; Zhang, Songning
2011-02-01
The functions of the medial longitudinal arch have been the focus of much research in recent years. Several studies have shown kinematic differences between high- and low-arched runners. No literature currently compares the inter-segmental foot motion of high- and low-arched recreational athletes. The purpose of this study was to examine inter-segmental foot motion in the frontal plane during dynamic loading activities in high- and low-arched female athletes. Inter-segmental foot motions were examined in 10 high- and 10 low-arched female recreational athletes. Subjects performed five barefooted trials in each of the following randomized movements: walking, running, downward stepping and landing. Three-dimensional kinematic data were recorded. High-arched athletes had smaller peak ankle eversion angles in walking, running and downward stepping than low-arched athletes. At the rear-midfoot joint high-arched athletes reached peak eversion later in walking and downward stepping than the low-arched athletes. The high-arched athletes had smaller peak mid-forefoot eversion angles in walking, running and downward stepping than the low-arched athletes. The current findings show that differences in foot kinematics between the high- and low-arched athletes were in position and not range of motion within the foot. Copyright © 2010 Elsevier B.V. All rights reserved.
Tran, Andrew A; Gatewood, Corey; Harris, Alex H S; Thompson, Julie A; Dragoo, Jason L
2016-12-01
Identification of biomechanical risk factors associated with anterior cruciate ligament (ACL) injury can facilitate injury prevention. The purpose of this study is to investigate the effects of three foot landing positions, "toe-in", "toe-out" and "neutral", on biomechanical risk factors for ACL injury in males and females. The authors hypothesize that 1) relative to neutral, the toe-in position increases the biomechanical risk factors for ACL injury, 2) the toe-out position decreases these biomechanical risk factors, and 3) compared to males, females demonstrate greater changes in lower extremity biomechanics with changes in foot landing position. Motion capture data on ten male and ten female volunteers aged 20-30 years (26.4 ± 2.50) were collected during double-leg jump landing activities. Subjects were asked to land on force plates and target one of three pre-templated foot landing positions: 0° ("neutral"), 30° internal rotation ("toe-in"), and 30° external rotation ("toe-out") along the axis of the anatomical sagittal plane. A mixed-effects ANOVA and pairwise Tukey post-hoc comparison were used to detect differences in kinematic and kinetic variables associated with biomechanical risk factors of ACL injury between the three foot landing positions. Relative to neutral, landing in the toe-in position increased peak hip adduction, knee internal rotation angles and moments (p < 0.01), and peak knee abduction angle (p < 0.001). Landing in the toe-in position also decreased peak hip flexion angle (p < 0.001) and knee flexion angle (p = 0.023). Landing in the toe-out position decreased peak hip adduction, knee abduction, and knee internal rotation angles (all p < 0.001). Male sex was associated with a smaller increase in hip adduction moment (p = 0.043) and knee internal rotation moment (p = 0.032) with toe-in landing position compared with female sex. Toe-in landing position exacerbates biomechanical risk factors associated with ACL injury, while toe-out landing position decreases these factors.
NASA Technical Reports Server (NTRS)
Kingsland, R. B.
1976-01-01
Results of wind tunnel tests, conducted at the Langley Research Center Unitary Plan Wind Tunnel, are presented. The model tested was an 0.010-scale version of the Vehicle 3 Space Shuttle Configuration. Pressure measurements were made on the launch configuration, Orbiter alone, external tank alone, and solid rocket booster alone, to provide heat transfer pressure data. The tests were conducted for a Mach number range from 2.36 to 4.6 and Reynolds number range from 1.2 to 5 million per foot. The model was tested at angles of attack from -10 to 20 deg for a sideslip angle range from -5 to +5 deg, and at sideslip angles from -5 to 48 deg for 0 deg angle of attack. Tabulated data are given and photographs of the test configuration are shown.
NASA Technical Reports Server (NTRS)
Jordan, Frank L., Jr.; Hahne, David E.
1992-01-01
An investigation was conducted in the Langley 30- by 60-Foot Tunnel and the Langley 12-Foot Low-Speed Tunnel to identify factors contributing to a directional divergence at high angles of attack for the EA-6B airplane. The study consisted of static wind-tunnel tests, smoke and tuft flow-visualization tests, and free-flight tests of a 1/8.5-scale model of the airplane. The results of the investigation indicate that the directional divergence of the airplane is brought about by a loss of directional stability and effective dihedral at high angles of attack. Several modifications were tested that significantly alleviate the stability problem. The results of the free-flight study show that the modified configuration exhibits good dynamic stability characteristics and could be flown at angles of attack significantly higher than those of the unmodified configuration.
NASA Technical Reports Server (NTRS)
Jacobs, P. F.; Flechner, S. G.
1976-01-01
A baseline wing and a version of the same wing fitted with winglets were tested. The longitudinal aerodynamic characteristics were determined through an angle-of-attack range from -1 deg to 10 deg at an angle of sideslip of 0 deg for Mach numbers of 0.750, 0.800, and 0.825. The lateral aerodynamic characteristics were determined through the same angle-of-attack range at fixed sideslip angles of 2.5 deg and 5 deg. Both configurations were investigated at Reynolds numbers of 13,000,000, per meter (4,000,000 per foot) and approximately 20,000,000 per meter (6,000,000 per foot). The winglet configuration showed slight increases over the baseline wing in static longitudinal and lateral aerodynamic stability throughout the test Mach number range for a model design lift coefficient of 0.53. Reynolds number variation had very little effect on stability.
Transonic wind tunnel tests of A.015 scale space shuttle orbiter model, volume 1
NASA Technical Reports Server (NTRS)
Struzynski, N. A.
1975-01-01
Transonic wind tunnel tests were run on a 0.015 scale model of the Space Shuttle Orbiter Vehicle in an eight-foot tunnel during August 1975. The purpose of the program was to obtain basic shuttle aerodynamic data through a full range of elevon and aileron deflections, verification of data obtained at other facilities, and effects of Reynolds numbers. The first part of a discussion of test procedures and results in both tabular and graphical form were presented. Tests were performed at Mach numbers from 0.35 to 1.20, and at Reynolds numbers for 3.5 million to 8.2 million per foot. The angle of attack was varied from -1 to +20 degrees at sideslip angles of -2, 0, +2 degrees. Sideslip was varied from -6 to +8 degrees at constant angles of attack from 0 to +20 degrees. Various aileron and ailevon settings were tested for various angles of attack.
Transonic wind tunnel tests of a .015 scale space shuttle orbiter model, volume 2
NASA Technical Reports Server (NTRS)
Struzynski, N. A.
1975-01-01
Transonic wind tunnel tests were run on a 0.015 scale model of the Space Shuttle Orbiter Vehicle in an eight-foot tunnel during August 1975. The purpose of the program was to obtain basic shuttle aerodynamic data through a full range of elevon and aileron deflections, verification of data obtained at other facilities, and effects of Reynolds numbers. The second part of a discussion of test procedures and results in both tabular and graphical form were presented. Tests were performed at Mach numbers from 0.35 to 1.20, and at Reynolds numbers from 3.5 million to 8.2 million per foot. The angle of attack was varied from -2 to +20 degrees at sideslip angles of -2, 0, +2 degrees. Sideslip was varied from -6 to +8 degrees at constant angles of attack from 0 to +20 degrees. Various aileron and ailevon settings were tested for various angles of attack.
Proposition of stair climb of a drop using chemical wettability gradient
NASA Astrophysics Data System (ADS)
Seerha, Prabh P. S.; Kumar, Parmod; Das, Arup K.; Mitra, Sushanta K.
2017-07-01
We propose a passive technique for a drop to climb along the staircase textured surface using chemical wettability gradients. The stair structure, droplet configuration, and contact angle gradient are modeled using Lagrangian smoothed particle hydrodynamics. The stair climb efficiency of the droplet is found to be a function of wettability gradient strength. Using analytical balance of actuation and resistive forces across droplets, physical reasons behind stair climbing are established and influencing parameters are identified. Evolution of the droplet shape along with the advancing and the receding contact angles is presented from where instantaneous actuation and hysteresis forces are calculated. Using history of Lagrangian particles, circulation at the foot of stairs and progressing development of the advancing drop front are monitored. Higher efficiency in stair climbing in the case of a bigger sized drop than smaller one is obtained from simulation results and realized from force balance. Difficulty in climbing steeper stairs is also demonstrated to delineate the effect of gravitational pull against the actuation force due to the wettability gradient.
NASA Technical Reports Server (NTRS)
Gamble, J. D.
1976-01-01
The model tested was a Langley-built 0.015-scale SSV Orbiter model with remote independently operated left and right elevon surfaces. The objective of the test was to generate a detailed aerodynamic data base for the current Shuttle Orbiter Configuration. Special attention was directed to definition of nonlinear aerodynamic characteristics by taking data at small increments, angle of attack, angle of sideslip, and elevon position. Six-component aerodynamic force and moment and elevon position data were recorded over an angle-of-attack range from -4 deg to 45 deg, at angles of sideslip of 0 deg, + or - 2 deg, and + or - 4 deg. Additional tests were made over an angle of sideslip range from -6 deg to 8 deg at selected angles of attack. The test Mach numbers were 2.86, 3.90, and 4.60 with Reynolds number held at a constant two million per foot.
Biomechanical analysis of standing long jump from varying starting positions.
Mackala, Krzysztof; Stodółka, Jacek; Siemienski, Adam; Coh, Milan
2013-10-01
The purpose of this study was (a) to investigate the effect of the different foot movement (placement) during take-off and the initial knee joint angle used in standing long jump by the ground reaction forces analysis and 3-dimensional motion analysis (BTS SMART motion) and (b) investigate how the jump performances of different foot placement is related to the electromyography (EMG) activity (Noraxon) of 3 selected muscle groups (m. gastrocnemius, m. gluteus maximus, m. rectus femoris, m. tibialis anterior, m. biceps femoris, and m. vastus medialis). Six high caliber sprinters (100 m: 10.87 ± 0.38 seconds and 400 m: 46.75 ± 1.05 seconds) performed a series of jumps from parallel and straddle foot placement at take-off on a 2 force platform (Kistler model 9286B) to determine if a different pattern of take-off improves jumping distance. Using kinematic and kinetic data, the knee joint angle, the trajectories of center of mass (COM), magnitude of take-off peak force, and impulse during take-off phase were calculated. Average standing long jump performances with straddle foot placement were 13.58 cm (5.18%) above that from parallel feet placement. The take-off velocity with 90° knee initial angle initiation of take-off was not different (1.18 and 1.17 m·s, respectively) between the 2 jumps. The take-off angles on the COM trajectory also showed differences (69.87 and 66.8°, respectively) between each other. The contribution (EMG activation) made by the 6 muscles were almost the same during all phases for the 2 jumps; however, some differences can be found, in either unilateral (single leg) or sums of both legs (bilateral) measurements. A recommendation can be formulated that the contribution of straddle foot placement during take-off can significantly increase the value of power measurement especially when the evaluation requires a complex movement structure with the division on the left and right legs, for example, sprint start from block.
The effect of gender on foot anthropometrics in older people.
Paiva de Castro, Alessandra; Rebelatto, Jose Rubens; Aurichio, Thais Rabiatti
2011-08-01
Some questions remain regarding the anthropometric differences between the feet of young men and women, but the gap is much greater when dealing with older adults. No studies were found concerning these differences in an exclusively older adult population, which makes it difficult to manufacture shoes based on the specific anthropometric measurements of the older adult population and according to gender differences. To identify differences between the anthropometric foot variables of older men and women. Cross-sectional. 154 older women (69.0 ± 6.8 y) and 131 older men (69.0 ± 6.5 y). The foot evaluations comprised the variables of width, perimeter, height, length, 1st and 5th metatarsophalangeal angles, the Arch Index (AI), and the Foot Posture Index (FPI). A data analysis was performed using t test and a post hoc power analysis. Women showed significantly higher values for the width and perimeter of the toes, width of the metatarsal heads, and width of the heel and presented significantly lower values for the height of the dorsal foot after normalization of the data to foot length. The 1st and 5th metatarsophalangeal angles were smaller in the men. There were no differences between men and women with respect to AI and FPI. Overall, the current study shows evidence of differences between some of the anthropometric foot variables of older men and women that must be taken into account for the manufacture of shoes for older adults.
Evaluation of a hemispherical head flow direction sensor for inlet duct measurements
NASA Technical Reports Server (NTRS)
Bennett, D. L.
1975-01-01
A hemispherical head flow direction sensor was tested in a wind tunnel to evaluate its effectiveness for measuring dynamic duct flow direction angles of plus and minus 27 degrees. The tests were conducted at Reynolds numbers of 3.8 million per meter (1.0 million per foot) and 4.92 million per meter (1.5 million per foot) and at Mach numbers from 0.30 to 0.70. The design criteria for the probe are discussed and the wind tunnel results are presented. Three techniques for deriving the flow angles are described.
EMG and tibial shock upon the first attempt at barefoot running.
Olin, Evan D; Gutierrez, Gregory M
2013-04-01
As a potential means to decrease their risk of injury, many runners are transitioning into barefoot running. Habitually shod runners tend to heel-strike (SHS), landing on their heel first, while barefoot runners tend to mid-foot or toe-strike (BTS), landing flat-footed or on the ball of their foot before bringing down the rest of the foot including the heel. This study compared muscle activity, tibial shock, and knee flexion angle in subjects between shod and barefoot conditions. Eighteen habitually SHS recreational runners ran for 3 separate 7-minute trials, including SHS, barefoot heel-strike (BHS), and BTS conditions. EMG, tibial shock, and knee flexion angle were monitored using bipolar surface electrodes, an accelerometer, and an electrogoniometer, respectively. A one-way MANOVA for repeated measures was conducted and several significant changes were noted between SHS and BTS, including significant increases in average EMG of the medial gastrocnemius (p=.05), average and peak tibial shock (p<.01), and the minimum knee flexion angle (p<.01). Based on our data, the initial change in mechanics may have detrimental effects on the runner. While it has been argued that BTS running may ultimately be less injurious, these data indicate that habitually SHS runners who choose to transition into a BTS technique must undertake the process cautiously. Copyright © 2012 Elsevier B.V. All rights reserved.
The Drag of Airplane Wheels, Wheel Fairings, and Landing Gears - I
NASA Technical Reports Server (NTRS)
Herrnstein, William H; Biermann, David
1935-01-01
This report presents the results of tests made in the 7-by 10-foot wind tunnel and in the 20-foot tunnel of the National Advisory Committee for Aeronautics to determine the drag of a number of airplane wheels, wheel fairings, and landing gears designed or selected for an airplane of 3,000 pounds gross weight. All tests were made on full-size models; those in the 7-by 10-foot tunnel were made at air speeds up to 80 miles per hour and those in the 20-foot tunnel were made at air speeds up to 100 miles per hour. Although most of the landing-gear tests were made in conjunction with a fuselage and at 0 degree pitch angle, some of the tests were made in conjunction with fuselage plus wings and a radial air-cooled engine and at pitch angles from -5 degrees to 6 degrees to obtain an indication of the general effect of these various items on landing-gear drag. All tests were made in the absence of propeller slipstream.
Cooper, Minton Truitt; Coughlin, Michael J
2012-10-01
The aim of this study was to compare a distal subcapital oblique fifth metatarsal with a distal chevron osteotomy for correction of bunionette deformity. Twenty cadaveric feet were randomly assigned to undergo either a subcapital oblique or chevron osteotomy of the distal fifth metatarsal. Radiographic measurements, including 4-5 intermetatarsal angle (IMA), fifth metatarsophalangeal angle (5-MPA) and foot width, were compared between the 2 groups. Foot width and 5-MPA was significantly decreased in both groups with no difference between the groups. The 4-5 IMA was not significantly altered in either group. Decrease in foot width and 5-MPA was similarly achieved with either distal chevron or subcapital oblique osteotomy of the fifth metatarsal in normal cadaveric specimens. No significant difference was found between the 2 techniques in any of the radiographic parameters measured.
NASA Technical Reports Server (NTRS)
Johnson, J. D.; Burstadt, P. L.; Radford, W. D.
1975-01-01
A 2.112 percent scale Space Shuttle Solid Rocket Booster (SRB) was tested in a ten foot, supersonic wind tunnel. The test Mach numbers were 2.0 and 2.7. Test angles of attack were from minus 5 degrees to plus 185 degrees. The Reynolds numbers ranged from 0.514 to 2.81 million per foot. Test roll angles were 0, 22.5, 45, 90, and 135 degrees. The following configurations were tested: (1) SRB without external protuberances, (2) SRB with an electrical tunnel and a thrust attachment structure, (3) SRB with two engine shroud strakes, (4) SRB with eight engine shroud strakes, and (5) SRB with an electrical tunnel, thrust attachment structure, eight engine shroud strakes, and separation motors.
White grain mycetoma caused by Scedosporium apiospermum in North India: a case report.
Gupta, Munesh Kumar; Banerjee, Tuhina; Kumar, Dhirendra; Rastogi, Amit; Tilak, Ragini
2013-12-01
Mycetoma is chronic granulomatous infection of skin and subcutaneous tissue caused by both bacteria and fungi. We report a case of mycetoma caused by Scedosporium apiospermum in the right foot of a 45-year-old farmer in north India. The patient had a history of trauma in the sole of the right foot followed by discharge of white granules along with proximal progression. Scedosporium apiospermum was identified based on colony characteristics and microscopic features on slide culture. Mycetoma is a progressive disease. Foot is commonly affected in persons who walk barefoot, especially in south India. Untreated mycetoma progress and involve the underlying fasciae and tissues along with bones often resulting in loss of limb. By prompt and reliable diagnosis with corresponding antimicrobial administration, we can prevent further progression and limb disability.
Saraswat, Prabhav; MacWilliams, Bruce A; Davis, Roy B
2012-04-01
Several multi-segment foot models to measure the motion of intrinsic joints of the foot have been reported. Use of these models in clinical decision making is limited due to lack of rigorous validation including inter-clinician, and inter-lab variability measures. A model with thoroughly quantified variability may significantly improve the confidence in the results of such foot models. This study proposes a new clinical foot model with the underlying strategy of using separate anatomic and technical marker configurations and coordinate systems. Anatomical landmark and coordinate system identification is determined during a static subject calibration. Technical markers are located at optimal sites for dynamic motion tracking. The model is comprised of the tibia and three foot segments (hindfoot, forefoot and hallux) and inter-segmental joint angles are computed in three planes. Data collection was carried out on pediatric subjects at two sites (Site 1: n=10 subjects by two clinicians and Site 2: five subjects by one clinician). A plaster mold method was used to quantify static intra-clinician and inter-clinician marker placement variability by allowing direct comparisons of marker data between sessions for each subject. Intra-clinician and inter-clinician joint angle variability were less than 4°. For dynamic walking kinematics, intra-clinician, inter-clinician and inter-laboratory variability were less than 6° for the ankle and forefoot, but slightly higher for the hallux. Inter-trial variability accounted for 2-4° of the total dynamic variability. Results indicate the proposed foot model reduces the effects of marker placement variability on computed foot kinematics during walking compared to similar measures in previous models. Copyright © 2011 Elsevier B.V. All rights reserved.
Telfer, Scott; Gibson, Kellie S; Hennessy, Kym; Steultjens, Martijn P; Woodburn, Jim
2012-05-01
To determine, for a number of techniques used to obtain foot shape based around plaster casting, foam box impressions, and 3-dimensional scanning, (1) the effect the technique has on the overall reproducibility of custom foot orthoses (FOs) in terms of inter- and intracaster reliability and (2) the reproducibility of FO design by using computer-aided design (CAD) software in terms of inter- and intra-CAD operator reliability for all these techniques. Cross-sectional study. University laboratory. Convenience sample of individuals (N=22) with noncavus foot types. Not applicable. Parameters of the FO design (length, width at forefoot, width at rearfoot, and peak medial arch height), the forefoot to rearfoot angle of the foot shape, and overall volume match between device designs. For intra- and intercaster reliability of the different methods of obtaining the foot shape, all methods fell below the reproducibility quality threshold for the medial arch height of the device, and volume matching was <80% for all methods. The more experienced CAD operator was able to achieve excellent reliability (intraclass correlation coefficients >0.75) for all variables with the exception of forefoot to rearfoot angle, with overall volume matches of >87% of the devices. None of the techniques for obtaining foot shape met all the criteria for excellent reproducibility, with the peak arch height being particularly variable. Additional variability is added at the CAD stage of the FO design process, although with adequate operator experience good to excellent reproducibility may be achieved at this stage. Taking only basic linear or angular measurement parameters from the device may fail to fully capture the variability in FO design. Copyright © 2012 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.
46 CFR 170.173 - Criterion for vessels of unusual proportion and form.
Code of Federal Regulations, 2013 CFR
2013-10-01
... routes, there must be— (i) Positive righting arms to at least 35 degrees of heel; (ii) No down flooding... following angles: (A) Angle of maximum righting arm. (B) Angle of down flooding. (C) 40 degrees. (2) For... flooding point to at least 15 degrees; and (iii) At least 10 foot-degrees of energy to the smallest of the...
46 CFR 170.173 - Criterion for vessels of unusual proportion and form.
Code of Federal Regulations, 2014 CFR
2014-10-01
... routes, there must be— (i) Positive righting arms to at least 35 degrees of heel; (ii) No down flooding... following angles: (A) Angle of maximum righting arm. (B) Angle of down flooding. (C) 40 degrees. (2) For... flooding point to at least 15 degrees; and (iii) At least 10 foot-degrees of energy to the smallest of the...
46 CFR 170.173 - Criterion for vessels of unusual proportion and form.
Code of Federal Regulations, 2012 CFR
2012-10-01
... routes, there must be— (i) Positive righting arms to at least 35 degrees of heel; (ii) No down flooding... following angles: (A) Angle of maximum righting arm. (B) Angle of down flooding. (C) 40 degrees. (2) For... flooding point to at least 15 degrees; and (iii) At least 10 foot-degrees of energy to the smallest of the...
Influence of maturation on instep kick biomechanics in female soccer athletes.
Lyle, Mark A; Sigward, Susan M; Tsai, Liang-Ching; Pollard, Christine D; Powers, Christopher M
2011-10-01
The purpose of this study was to compare kicking biomechanics between young female soccer players at two different stages of physical maturation and to identify biomechanical predictors of peak foot velocity. Swing and stance limb kinematics and kinetics were recorded from 20 female soccer players (10 prepubertal, 10 postpubertal) while kicking a soccer ball using an angled two-step approach. Peak foot velocity as well as hip and knee kinematics and kinetics were compared between groups using independent-samples t-tests. Pearson correlation coefficients and stepwise multiple regression were used to identify predictors of peak foot velocity. Peak foot velocity and the peak swing limb net hip flexor moment was significantly greater in the postpubertal group when compared with the prepubertal group (13.4 vs 11.6 m·s(-1), P = 0.003; 1.22 vs 1.07 N·m·kg(-1)·m(-1), P = 0.03). Peak stance limb hip and knee extensor moments were not different between groups. Although the peak swing limb hip and knee flexion angles were similar between groups, the postpubertal group demonstrated significantly less peak stance limb hip and knee flexion angles when compared with the prepubertal group (P < 0.001 and P = 0.045). Using a linear regression model, swing limb peak hip flexor moment and peak swing limb hip extension range of motion combined to explain 65% of the variance in peak foot velocity. Despite a difference in stance limb kinematics, similar swing limb kinematics between groups indicates that the prepubertal female athletes kicked with a mature swing limb kick pattern. The ability to generate a large hip flexor moment of the swing limb seems to be an important factor for improving kicking performance in young female soccer players.
Cockcroft, John; Van Den Heever, Dawie
2016-01-01
This study describes foot positioning during the final two steps of the approach to the ball amongst professional rugby goal-kickers. A 3D optical motion capture system was used to test 15 goal-kickers performing 10 goal-kicks. The distance and direction of each step, as well as individual foot contact positions relative to the tee, were measured. The intra- and inter-subject variability was calculated as well as the correlation (Pearson) between the measurements and participant anthropometrics. Inter-subject variability for the final foot position was lowest (placed 0.03 ± 0.07 m behind and 0.33 ± 0.03 m lateral to the tee) and highest for the penultimate step distance (0.666 ± 0.149 m), performed at an angle of 36.1 ± 8.5° external to the final step. The final step length was 1.523 ± 0.124 m, executed at an external angle of 35.5 ± 7.4° to the target line. The intra-subject variability was very low; distances and angles for the 10 kicks varied per participant by 1.6-3.1 cm and 0.7-1.6°, respectively. The results show that even though the participants had variability in their run-up to the tee, final foot position next to the tee was very similar and consistent. Furthermore, the inter- and intra-subject variability could not be attributed to differences in anthropometry. These findings may be useful as normative reference data for coaching, although further work is required to understand the role of other factors such as approach speed and body alignment.
Takayanagi, Naoto; Sudo, Motoki; Fujii, Masahiko; Sakai, Hirokazu; Morimoto, Keiko; Tomisaki, Masumi; Niki, Yoshifumi; Tokimitsu, Ichiro
2018-03-01
[Purpose] This study evaluated gait parameters and foot pressure in two regions of the feet among older females with different personal care support needs to analyze factors that contribute to higher support requirements. [Subjects and Methods] Thirty-two older females were divided into support-need and care-need level groups. Gait parameters (speed, cadence, step length, step width, gait angle, toe angle, double support phase, swing phase, and stance phase) and foot pressure during a 5-m walk were measured and analyzed in the two groups. [Results] The percentage of the double support phase on both feet and the right stance phase were significantly higher in the care-need level group, while that of the right swing phase was significantly lower than that of the support-need level group. Additionally, the phase showing peak pressure on the left rear foot was significantly delayed and the left forefoot pressure in the terminal stance was significantly lower in the care-need level group than in the support-need level group. [Conclusion] These findings show that the temporal duration parameters and foot pressure on a particular side were significantly different between the two groups and suggest that these differences were associated with a higher care level.
Lee, Hong-Jae; Lim, Kil-Byung; Yoo, JeeHyun; Yun, Hyun-Ju; Jeong, Tae-Ho
2015-01-01
Objective To evaluate the effect of custom-molded foot orthoses on foot pain and balance in children with symptomatic flexible flat foot 1 month and 3 months after fitting foot orthosis. Method A total of 24 children over 6 years old with flexible flat feet and foot pain for at least 6 months were recruited for this study. Their resting calcaneal stance position and calcaneal pitch angle were measured. Individual custom-molded rigid foot orthoses were prescribed using inverted orthotic technique to control foot overpronation. Pain questionnaire was used to obtain pain sites, degree, and frequency. Balancing ability was determined using computerized posturography. These evaluations were performed prior to custom-molded foot orthoses, 1 month, and 3 months after fitting foot orthoses. Result Of 24 children with symptomatic flexible flat feet recruited for this study, 20 completed the study. Significant (p<0.001) improvements in pain degree and frequency were noted after 1 and 3 months of custom-molded foot orthoses. In addition, significant (p<0.05) improvement in balancing ability was found after 3 months of custom-molded foot orthoses. Conclusion Short-term use of custom-molded foot orthoses significantly improved foot pain and balancing ability in children with symptomatic flexible flat foot. PMID:26798604
Frontal plane landing mechanics in high-arched compared with low-arched female athletes.
Powell, Douglas W; Hanson, Nicholas J; Long, Benjamin; Williams, D S Blaise
2012-09-01
To examine ground reaction forces (GRFs); frontal plane hip, knee, and ankle joint angles; and moments in high-arched (HA) and low-arched (LA) athletes during landing. Experimental study. Controlled research laboratory. Twenty healthy female recreational athletes (10 HA and 10 LA). Athletes performed 5 barefoot drop landings from a height of 30 cm. Frontal plane ankle, knee, and hip joint angles (in degrees) at initial contact, peak vertical GRF, and peak knee flexion; peak ankle, knee, and hip joint moments in the frontal plane. Vertical GRF profiles were similar between HA and LA athletes (P = 0.78). The HA athletes exhibited significantly smaller peak ankle inversion angles than the LA athletes (P = 0.01) at initial contact. At peak vertical GRF, HA athletes had significantly greater peak knee (P = 0.01) and hip abduction angles than LA athletes (P = 0.02). There were no significant differences between HA and LA athletes in peak joint moments (hip: P = 0.68; knee: P = 0.71; ankle: P = 0.15). These findings demonstrate that foot type is associated with altered landing mechanics, which may underlie lower extremity injuries. The ankle-driven strategy previously reported in female athletes suggests that foot function may have a greater relationship with lower extremity injury than that in male athletes. Future research should address the interaction of foot type and gender during landing tasks.
Osis, Sean T; Hettinga, Blayne A; Leitch, Jessica; Ferber, Reed
2014-08-22
As 3-dimensional (3D) motion-capture for clinical gait analysis continues to evolve, new methods must be developed to improve the detection of gait cycle events based on kinematic data. Recently, the application of principal component analysis (PCA) to gait data has shown promise in detecting important biomechanical features. Therefore, the purpose of this study was to define a new foot strike detection method for a continuum of striking techniques, by applying PCA to joint angle waveforms. In accordance with Newtonian mechanics, it was hypothesized that transient features in the sagittal-plane accelerations of the lower extremity would be linked with the impulsive application of force to the foot at foot strike. Kinematic and kinetic data from treadmill running were selected for 154 subjects, from a database of gait biomechanics. Ankle, knee and hip sagittal plane angular acceleration kinematic curves were chained together to form a row input to a PCA matrix. A linear polynomial was calculated based on PCA scores, and a 10-fold cross-validation was performed to evaluate prediction accuracy against gold-standard foot strike as determined by a 10 N rise in the vertical ground reaction force. Results show 89-94% of all predicted foot strikes were within 4 frames (20 ms) of the gold standard with the largest error being 28 ms. It is concluded that this new foot strike detection is an improvement on existing methods and can be applied regardless of whether the runner exhibits a rearfoot, midfoot, or forefoot strike pattern. Copyright © 2014 Elsevier Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
Ball, J. W.
1976-01-01
Wind tunnel tests are reported on a 0.015-scale SSV orbiter model with remote independently operated left and right elevon surfaces. Special attention was directed to definition of nonlinear aerodynamic characteristics by taking data at small increments. Six component aerodynamic force and moment and elevon position data were recorded for the space shuttle orbiter with various elevon, aileron rudder and speed brake deflection combinations over an angle of attack range from -4 deg to 32 deg at angles of sideslip of 0 deg and 3 deg. Additional tests were made over an angle of sideslip range from -6 deg to 8 deg at selected angles of attack. Test Mach numbers were 2.86, 2.90, 3.90 and 4.60 with Reynolds numbers held at a constant 2.0 x 1 million per foot.
NASA Technical Reports Server (NTRS)
Ball, J. W.; Edwards, C. R.
1976-01-01
Tests were conducted in the NASA/LaRC 8 foot transonic wind tunnel from March 26 through 31, 1976. The model was a 0.015 scale SSV Orbiter with forebody modifications to simulate slight reductions in the reusable surface insulation (RSI) thickness. Six component aerodynamic force and moment data were obtained at Mach numbers from 0.35 to 1.20 over an angle of attack range from -2 deg to 20 deg at sideslip angles of 0 deg and 5 deg.
Dynamic stability test results on an 0.024 scale B-1 air vehicle
NASA Technical Reports Server (NTRS)
Beeman, R. R.
1972-01-01
Dynamic longitudinal and lateral-directional stability characteristics of the B-1 air vehicle were investigated in three wind tunnels at the Langley Research Center. The main rotary derivatives were obtained for an angle of attack range of -3 degrees to +16 degrees for a Mach number range of 0.2 to 2.16. Damping in roll data could not be obtained at the supersonic Mach numbers. The Langley 7 x 10 foot high speed tunnel, the 8 foot transonic pressure tunnel, and the 4 foot Unitary Plan wind tunnel were the test sites. An 0.024 scale light-weight model was used on a forced oscillation type balance. Test Reynolds number varied from 474,000/ft to 1,550,000/ft. through the Mach number range tested. The results showed that the dynamic stability characteristics of the model in pitch and roll were generally satisfactory up to an angle attack of about +6 degrees. In the wing sweep range from 15 to 25 degrees the positive damping levels in roll deteriorated rapidly above +2 degrees angle of attack. This reduction in roll damping is believed to be due to the onset of separation over the wing as stall is approached.
Quantitative Analysis and Development of the Fore Feet of Arabian Foals from Birth to 1 Year of Age.
Faramarzi, Babak; Salinger, Allison; Kaneps, Andris; Nout-Lomas, Yvette; Greene, Holly; Dong, Fanglong
2017-11-01
Objectives The goal of this study was to quantify external and internal anatomical characteristics of the foal foot throughout the first year of age. Methods Digital radiographs and photographs were taken bimonthly of the forefeet of nine Arabian foals, beginning at about 2 weeks of age until 12 months of age. Sixty-eight linear and angular variables were measured using NIH (National Institutes of Health) Image J software. Statistical analyses were performed using piecewise random coefficient model and p -values < 0.05 were considered significant. Results Distinct changes in hoof development were identified between 4 and 8 months of age. Distinct changes were identified in several external (conformational) measurements including hoof solar widths and lengths, palmar heel lengths, toe and heel angles and in several internal (radiographic) measurements including the widths and lengths of the phalanges and sesamoid bones as well as joint angles. Clinical Significance Existing knowledge of distal limb development in foals, particularly the foot, is limited. These findings define the measurable changes of the foal foot as it grows during the first year of life. These data provide an insight into the transformation of the hoof from its initial oval to a circular shape and from a club-like, cylindrical conformation to a more angled, conical conformation. This paper quantifies this development, ultimately allowing a better understanding of morphological changes in the foot of the growing foal. Schattauer GmbH Stuttgart.
Prenton, Sarah; Kenney, Laurence P; Stapleton, Claire; Cooper, Glen; Reeves, Mark L; Heller, Ben W; Sobuh, Mohammad; Barker, Anthony T; Healey, Jamie; Good, Timothy R; Thies, Sibylle B; Howard, David; Williamson, Tracey
2014-10-01
To investigate the feasibility of unsupervised community use of an array-based automated setup functional electrical stimulator for current foot-drop functional electrical stimulation (FES) users. Feasibility study. Gait laboratory and community use. Participants (N=7) with diagnosis of unilateral foot-drop of central neurologic origin (>6mo) who were regular users of a foot-drop FES system (>3mo). Array-based automated setup FES system for foot-drop (ShefStim). Logged usage, logged automated setup times for the array-based automated setup FES system and diary recording of problems experienced, all collected in the community environment. Walking speed, ankle angles at initial contact, foot clearance during swing, and the Quebec User Evaluation of Satisfaction with Assistive Technology version 2.0 (QUEST version 2.0) questionnaire, all collected in the gait laboratory. All participants were able to use the array-based automated setup FES system. Total setup time took longer than participants' own FES systems, and automated setup time was longer than in a previous study of a similar system. Some problems were experienced, but overall, participants were as satisfied with this system as their own FES system. The increase in walking speed (N=7) relative to no stimulation was comparable between both systems, and appropriate ankle angles at initial contact (N=7) and foot clearance during swing (n=5) were greater with the array-based automated setup FES system. This study demonstrates that an array-based automated setup FES system for foot-drop can be successfully used unsupervised. Despite setup's taking longer and some problems, users are satisfied with the system and it would appear as effective, if not better, at addressing the foot-drop impairment. Further product development of this unique system, followed by a larger-scale and longer-term study, is required before firm conclusions about its efficacy can be reached. Copyright © 2014 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.
Ko, Mansoo; Hughes, Lynne; Lewis, Harriet
2012-03-01
The impact of walking speed has not been evaluated as a feasible outcome measure associated with peak plantar pressure (PPP) distribution, which may result in tissue damage in persons with diabetic foot complications. The objective of this pilot study was to determine the walking speed and PPP distribution during barefoot walking in persons with diabetes. Nine individuals with diabetes and nine age-gender matched individuals without diabetes participated in this study. Each individual was marked at 10 anatomical landmarks for vibration and tactile pressure sensation tests to determine the severity of sensory deficits on the plantar surface of the dominant limb foot. A steady state walking speed, PPP, the fore and rear foot (F/R) PPP ratio and gait variables were measured during barefoot walking. Persons with diabetes had a significantly slower walking speed than the age-gender matched group resulting in a significant reduction of PPP at the F/R foot during barefoot walking (p < 0.05). There was no significant difference in F/R foot PPP ratio in the diabetic group compared with the age-gender matched group during barefoot walking (p > 0.05). There was a significant difference between the diabetic and non-diabetic groups for cadence, step time, toe out angle and the anterior-posterior excursion (APE) for centre of force (p < 0.05). Walking speed may be a potential indicator for persons with diabetes to identify PPP distribution during barefoot walking in a diabetic foot. However, the diabetic group demonstrated a more cautious walking pattern than the age-gender matched group by decreasing cadence, step length and APE, and increasing step time and toe in/out angle. People with diabetes may reduce the risk of foot ulcerations as long as they are able to prevent severe foot deformities such as callus, hammer toe or charcot foot. Copyright © 2011 John Wiley & Sons, Ltd.
Wireless patient monitoring on shoe for the assessment of foot dysfunction: an overview
NASA Astrophysics Data System (ADS)
Abraham, Jose K.; Whitchurch, Ashwin K.; Varadan, Vijay K.; Sarukesi, Karunakaran
2003-04-01
This paper presents an overview of the wireless monitoring and quantitative assessment of joint dynamics of ankle which has suffered from soft tissue injury, immobilization or any dysfunction with special focus on the treatment and rehabilitation applications. The inadequacy of a reliable and easy method for continuous measurement and recording of ankle movement while doing physical therapy makes the monitoring of its progress difficult. Development of a wireless ankle motion monitoring system inside the shoe provides information on several aspects of activities associated with a dysfunctional foot. The system is based on continuous wireless monitoring of signals from accelerometers and gyroscopes fixed inside the shoe. From these signals, the duration, rate, and moment of occurrence of activities associated with mobility (e.g., lying, sitting, standing, walking up and down, running, cycling, wheelchair use and general movement) and transitions (changes in angle) can be detected. Information about the movement can be obtained by the acceleration sensors, which is related to the intensity of body-segment movement. Apart from monitoring accelerations, other signals due to turning and angular movements can be obtained using the miniature gyroscope attached to the shoe.
NASA Technical Reports Server (NTRS)
Gamble, J. D.; Buhl, M. L., Jr.; Parrell, H.
1975-01-01
The objective of the test was to generate a detailed aerodynamic data base which can be used to substantiate the aerodynamic design data book for the current shuttle orbiter configuration. Special attention was directed to definition of nonlinear aerodynamic characteristics by taking data at small increments in Mach number, angle of attack, and elevon position. Six-component aerodynamic force and moment and elevon position data were recorded over an angle-of-attack range from -4 deg to 20 deg, at angles of sideslip of 0 deg and 2 deg. The test Mach numbers were from 0.35 to 1.20. The Reynolds number for most of the test was held at a constant 3.5 million per foot.
Steady-state and transitional aerodynamic characteristics of a wing in simulated heavy rain
NASA Technical Reports Server (NTRS)
Campbell, Bryan A.; Bezos, Gaudy M.
1989-01-01
The steady-state and transient effects of simulated heavy rain on the subsonic aerodynamic characteristics of a wing model were determined in the Langley 14- by 22-Foot Subsonic Tunnel. The 1.29 foot chord wing was comprised of a NACA 23015 airfoil and had an aspect ratio of 6.10. Data were obtained while test variables of liquid water content, angle of attack, and trailing edge flap angle were parametrically varied at dynamic pressures of 10, 30, and 50 psf (i.e., Reynolds numbers of .76x10(6), 1.31x10(6), and 1.69x10(6)). The experimental results showed reductions in lift and increases in drag when in the simulated rain environment. Accompanying this was a reduction of the stall angle of attack by approximately 4 deg. The transient aerodynamic performance during transition from dry to wet steady-state conditions varied between a linear and a nonlinear transition.
NASA Technical Reports Server (NTRS)
Johnson, J. D.; Braddock, W. F.
1974-01-01
A test of a 0.563 percent scale space shuttle Solid Rocket Booster (SRB) model, MSFC Model 449, was conducted in a trisonic wind tunnel. Test Mach numbers were 0.4, 0.6, 0.9, 1.2, 1.96, 3.48, 4.0, 4.45, and 4.96. Test angles-of-attack ranged from minus 10 degrees to 190 degrees. Test Reynolds numbers ranged from 3.0 million per foot to 8.6 million per foot. Test roll angles were 0, 11.25, 22.5, 45, and 90 degrees. In addition to the static stability evaluation of the primary SRB configuration, five parametric investigations were made: (1) effect of Reynolds number, (2) effect of engine shroud flare angle, (3) effect of engine shroud length, (4) effect of engine shroud strakes, and (5) effect of engine shroud strakes and trust vector control bottles.
Reliability of Two Smartphone Applications for Radiographic Measurements of Hallux Valgus Angles.
Mattos E Dinato, Mauro Cesar; Freitas, Marcio de Faria; Milano, Cristiano; Valloto, Elcio; Ninomiya, André Felipe; Pagnano, Rodrigo Gonçalves
The objective of the present study was to assess the reliability of 2 smartphone applications compared with the traditional goniometer technique for measurement of radiographic angles in hallux valgus and the time required for analysis with the different methods. The radiographs of 31 patients (52 feet) with a diagnosis of hallux valgus were analyzed. Four observers, 2 with >10 years' experience in foot and ankle surgery and 2 in-training surgeons, measured the hallux valgus angle and intermetatarsal angle using a manual goniometer technique and 2 smartphone applications (Hallux Angles and iPinPoint). The interobserver and intermethod reliability were estimated using intraclass correlation coefficients (ICCs), and the time required for measurement of the angles among the 3 methods was compared using the Friedman test. A very good or good interobserver reliability was found among the 4 observers measuring the hallux valgus angle and intermetatarsal angle using the goniometer (ICC 0.913 and 0.821, respectively) and iPinPoint (ICC 0.866 and 0.638, respectively). Using the Hallux Angles application, a very good interobserver reliability was found for measurements of the hallux valgus angle (ICC 0.962) and intermetatarsal angle (ICC 0.935) only among the more experienced observers. The time required for the measurements was significantly shorter for the measurements using both smartphone applications compared with the goniometer method. One smartphone application (iPinPoint) was reliable for measurements of the hallux valgus angles by either experienced or nonexperienced observers. The use of these tools might save time in the evaluation of radiographic angles in the hallux valgus. Copyright © 2016 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.
The epidemiology and clinical manifestations of hamstring muscle and plantar foot flexor shortening.
Joźwiak, M; Pietrzak, S; Tobjasz, F
1997-07-01
A population of 920 healthy children was studied with the aim of assessing the incidence of hamstring muscle and plantar foot flexor tightness, and to correlate such symptoms with gait, posture, and low back discomfort or pain. Special attention was paid to the popliteal angle and dorsal foot flexion. The borderline values for the popliteal angle in the following age groups were, boys: 3 to 5 years, 40 degrees; 6 to 15 years, 50 degrees; and 16 to 19 years, 40 degrees; girls: 3 to 5 years, 30 degrees; 6 to 14 years, 45 degrees; 15 to 19 years, 30 degrees. The borderline values for dorsal foot flexion in the following age groups were 3 to 4 years, 7 degrees; 5 to 13 years, 10 degrees; and 14 to 19 years, 5 degrees. The results obtained indicate a natural increase in hamstring tightness, particularly shortly before the pubertal growth spurt. This seems to be linked with the natural evolution of lumbar lordosis and pelvic tilt. When hamstring tightness surpassed borderline values, dorsiflexion and lumbar lordosis decreased leading to postural deformities, bending-forward deficit, discomfort when sitting, and a shambling gait.
Graf, Eveline S.; Wright, Ian C.; Stefanyshyn, Darren J.
2012-01-01
The two main movements occurring between the forefoot and rearfoot segment of a human foot are flexion at the metatarsophalangeal joints and torsion in the midfoot. The location of the torsion axis within the foot is currently unknown. The purpose of this study was to develop a method based on Cardan angles and the finite helical axis approach to calculate the torsion axis without the effect of flexion. As the finite helical axis method is susceptible to error due to noise with small helical rotations, a minimal amount of rotation was defined in order to accurately determine the torsion axis location. Using simulation, the location of the axis based on data containing noise was compared to the axis location of data without noise with a one-sample t-test and Fisher's combined probability score. When using only data with helical rotation of seven degrees or more, the location of the torsion axis based on the data with noise was within 0.2 mm of the reference location. Therefore, the proposed method allowed an accurate calculation of the foot torsion axis location. PMID:22666303
The influence of foot position on scrum kinetics during machine scrummaging.
Bayne, Helen; Kat, Cor-Jacques
2018-05-23
The purpose of this study was to investigate the effect of variations in the alignment of the feet on scrum kinetics during machine scrummaging. Twenty nine rugby forwards from amateur-level teams completed maximal scrum efforts against an instrumented scrum machine, with the feet in parallel and non-parallel positions. Three-dimensional forces, the moment about the vertical axis and sagittal plane joint angles were measured during the sustained pushing phase. There was a decrease in the magnitude of the resultant force and compression force in both of the non-parallel conditions compared to parallel and larger compression forces were associated with more extended hip and knee angles. Scrummaging with the left foot forward resulted in the lateral force being directed more towards the left and the turning moment becoming more clockwise. These directional changes were reversed when scrummaging with the right foot forward. Scrummaging with the right foot positioned ahead of the left may serve to counteract the natural clockwise wheel of the live scrum and could be used to achieve an anti-clockwise rotation of the scrum for tactical reasons. However, this would be associated with lower resultant forces and a greater lateral shear force component directed towards the right.
Jordán-Palomar, Elena Irene; Javierre, Etelvina; Rey-Vasalo, José; Alfaro-Santafé, Víctor; Gómez-Benito, María José
Most pedobarographic studies of microsurgical foot reconstruction have been retrospective. In the present study, we report the results from a prospective pedobarographic study of a patient after microsurgical reconstruction of her foot with a latissimus dorsi flap and a cutaneous paddle, with a 42-month follow-up period. We describe the foot reconstruction plan and the pedobarographic measurements and analyzed its functional outcome. The goal of the present study was to demonstrate that pedobarography could have a role in the treatment of foot reconstruction from a quantitative perspective. The pedobarographic measurements were recorded after the initial coverage surgery and 2 subsequent foot remodeling procedures. A total of 4 pedobarographic measurements and 2 gait analyses were recorded and compared for both the noninvolved foot and the injured foot. Furthermore, the progress of the reconstructed foot was critically evaluated using this method. Both static and dynamic patterns were compared at subsequent follow-up visits after the foot reconstruction. The values and progression of the foot shape, peak foot pressure (kPa), average foot pressure (kPa), total contact surface (cm 2 ), loading time (%), and step time (ms) were recorded. Initially, the pressure distribution of the reconstructed foot showed higher peak values at nonanatomic locations, revealing a greater ulceration risk. Over time, we found an improvement in the shape and values of these factors in the involved foot. To homogenize the pressure distribution and correct the imbalance between the 2 feet, patient-specific insoles were designed and fabricated. In our patient, pedobarography provided an objective, repeatable, and recordable method for the evaluation of the reconstructed foot. Pedobarography can therefore provide valuable insights into the prevention of pressure ulcers and optimization of rehabilitation. Copyright © 2016 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Re, Richard, J.; Capone, Francis J.
1998-01-01
An investigation has been conducted in the Langley 16-Foot Transonic Tunnel to determine boundary-reflected disturbance lengths at low supersonic Mach numbers in the octagonally shaped test section. A body of revolution that had a nose designed to produce a bow shock and flow field similar to that about the nose of a supersonic transport configuration was used. The impingement of reflected disturbances on the model was determined from static pressures measured on the surface of the model. Test variables included Mach number (0.90 to 1.25), model angle of attack (nominally -10, 0, and 10), and model roll angle.
A free-trailing vane flow direction indicator employing a linear output Hall effect transducer
NASA Technical Reports Server (NTRS)
Zell, Peter T.; Mcmahon, Robert D.
1988-01-01
The Hall effect vane (HEV) was developed to measure flow angularity in the NASA 40-by-80-foot and 80-by-120-foot wind tunnels. This indicator is capable of sensing flow direction at air speeds from 5 to 300 knots and over a + or - 40 deg angle range with a resolution of 0.1 deg. A free-trailing vane configuration employing a linear output Hall effect transducer as a shaft angle resolver was used. The current configuration of the HEV is designed primarily for wind tunnel calibration testing; however, other potential applications include atmospheric, flight or ground research testing. The HEV met initial design requirements.
NASA Technical Reports Server (NTRS)
Nichols, M. E.
1974-01-01
Data obtained from the wind tunnel tests of a scale model of the space shuttle orbiter configuration 140 A/B are presented. The test was conducted at Mach numbers of 2.5, 3.9, and 4.6 with Reynolds numbers from 1.25 million per foot to 5.0 million per foot. Various control surface settings were used ranging from an angle of attack range from minus 4 to plus 42 degrees at zero angle of yaw. Longitudinal stability and control characteristics of the space shuttle configuration were analyzed.
NASA Technical Reports Server (NTRS)
Kingsland, R. B.; Lockman, W. K.
1975-01-01
The model tested was an 0.0175-scale version of the vehicle 3 space shuttle configuration. Temperature measurements were made on the launch configuration, orbiter plus tank, orbiter alone, tank alone, and solid rocket booster (SRB) alone to provide heat transfer data. The test was conducted at free stream Mach numbers of 5.3 and 7.3 and at free stream Reynolds numbers of 1.5, 3.7, 5.0, and 7.0 million per foot. The model was tested at angles of attack from -5 deg to 20 deg and side slip angles of -5 deg and 0 deg.
NASA Technical Reports Server (NTRS)
Henderson, W. P.; Leavitt, L. D.
1981-01-01
The tests were conducted at Mach numbers from 0.40 to 0.90, at angles of attack up to 45 deg for the lower Mach numbers, and at angles of sideslip up to 15 deg. The model variations under study included adding a canard surface and deflecting horizontal tails, ailerons, and rudders.
Biscarini, Andrea; Botti, Fabio M; Pettorossi, Vito E
2013-02-01
We developed a biomechanical model to determine the joint torques and loadings during squatting with a backward/forward-inclined Smith machine. The Smith squat allows a large variety of body positioning (trunk tilt, foot placement, combinations of joint angles) and easy control of weight distribution between forefoot and heel. These distinctive aspects of the exercise can be managed concurrently with the equipment inclination selected to unload specific joint structures while activating specific muscle groups. A backward (forward) equipment inclination decreases (increases) knee torque, and compressive tibiofemoral and patellofemoral forces, while enhances (depresses) hip and lumbosacral torques. For small knee flexion angles, the strain-force on the posterior cruciate ligament increases (decreases) with a backward (forward) equipment inclination, whereas for large knee flexion angles, this behavior is reversed. In the 0 to 60 degree range of knee flexion angles, loads on both cruciate ligaments may be simultaneously suppressed by a 30 degree backward equipment inclination and selecting, for each value of the knee angle, specific pairs of ankle and hip angles. The anterior cruciate ligament is safely maintained unloaded by squatting with backward equipment inclination and uniform/forward foot weight distribution. The conditions for the development of anterior cruciate ligament strain forces are clearly explained.
De Asha, Alan R; Munjal, Ramesh; Kulkarni, Jai; Buckley, John G
2014-08-01
If a prosthetic foot creates resistance to forwards shank rotation as it deforms during loading, it will exert a braking effect on centre of mass progression. The present study determines whether the centre of mass braking effect exerted by an amputee's habitual rigid 'ankle' foot was reduced when they switched to using an 'Echelon' hydraulic ankle-foot device. Nineteen lower limb amputees (eight trans-femoral, eleven trans-tibial) walked overground using their habitual dynamic-response foot with rigid 'ankle' or 'Echelon' hydraulic ankle-foot device. Analysis determined changes in how the centre of mass was transferred onto and above the prosthetic-foot, freely chosen walking speed, and spatio-temporal parameters of gait. When using the hydraulic device both groups had a smoother/more rapid progression of the centre of pressure beneath the prosthetic hindfoot (p≤0.001), and a smaller reduction in centre of mass velocity during prosthetic-stance (p<0.001). As a result freely chosen walking speed was higher in both groups when using the device (p≤0.005). In both groups stance and swing times and cadence were unaffected by foot condition whereas step length tended (p<0.07) to increase bilaterally when using the hydraulic device. Effect size differences between foot types were comparable across groups. Use of a hydraulic ankle-foot device reduced the foot's braking effect for both amputee groups. Findings suggest that attenuation of the braking effect from the foot in early stance may be more important to prosthetic-foot function than its ability to return energy in late stance. Copyright © 2014. Published by Elsevier Ltd.
Wang, Shanxi; Li, Jun; Huang, Fuguo; Liu, Lei
2017-05-01
To review the application and research progress of subtalar distraction bone block arth-rodesis in the treatment of calcaneus fracture malunion. The recent literature concerning the history, surgical technique, postoperative complication, indications, and curative effect of subtalar distraction arthrodesis with bone graft block interposition in the treatment of calcaneus fracture malunion was summarized and analyzed. Subtalar distraction bone block arthrodesis is one of the main ways to treat calcaneus fracture malunion, including a combined surgery with subtalar arthrodesis and realignment surgery for hindfoot deformity using bone block graft. The advantage is on the base of subtalar joint fusion, through one-time retracting subtalar joint, the posterior articular surface of subtalar joint implants bone block can partially restore calcaneal height, thus improving the function of the foot. Compared with other calcaneal malunion treatments, subtalar distraction arthrodesis is effective to correct complications caused by calcaneus fracture malunion, and it can restore the height of talus and calcaneus, correct loss of talocalcaneal angle, and ease pain. Subtalar distraction bone block arthrodesis has made remarkable progress in the treatment of calcaneus fracture malunion, but it has the disadvantages of postoperative nonunion and absorption of bone block, so further study is needed.
Correction of hypermobile flatfoot in children by molded insert.
Bordelon, R L
1980-11-01
One hundred feet in 50 children between the ages of 3 and 9 years with a diagnosis of idiopathic hypermobile flatfoot had a custom-molded insert ordered. A specific method of casting, correcting the various components of the deformity was utilized. An 1/8-inch polypropolene insert was fabricated from the positive cast. The insert was worn in leather shoes with a long counter, steel shank, and Thomas heel. The flatfoot was evaluated and classified by measurement of the talometatarsal angle on a standing lateral X-ray. The insert was fabricated so that the standing lateral talometatarsal angle was corrected to neutral with the insert on the foot and the foot in the shoe. The preliminary reports indicate that a correction can be obtained at the rate of 0.41 degrees per month or approximately 5 degrees per year. There was no significant loss of motion of the foot or the ankle. Perhaps this regimen may be utilized in those children with a hypermobile flatfoot for whom treatment is advised.
NASA Technical Reports Server (NTRS)
Greene, Francis A.; Buck, Gregory M.; Wood, William A.
2001-01-01
Computational and experimental hypersonic aerodynamic forces and moments and aeroheating levels for Kistler Aerospace Corporation's baseline orbiter vehicle at incidence are presented. Experimental data were measured in ground-based facilities at the Langley Research Center and predictions were performed using the Langley Aerothermodynamic Upwind Relaxation Algorithm code. The test parameters were incidence (-4 to 24 degrees), freestream Mach number (6 to 10),freestream ratio o specific heats (1.2 to 1.4), and freestream Reynolds number (0.5 to 8.0 million per foot). The effects of these parameters on aerodynamic characteristics, as well as the effects of Reynolds number on measured heating levels are discussed. Good agreement between computational and experimental aerodynamic and aeroheating values were observed over the wide range of test parameters examined. Reynolds number and ratio of specific heats were observed to significantly alter the trim L/D value. At Mach 6, laminar flow was observed along the entire windward centerline tip to the flare for all angles and Reynolds numbers tested. Flow over the flare transitioned from laminar to transitional/turbulent between 4 and 8 million per foot at 8 and 12 degrees angle of attack, and near 4 million per foot at 16 degrees angle of attack.
Acquired midfoot deformity and function in individuals with diabetes and peripheral neuropathy.
Hastings, Mary K; Mueller, Michael J; Woodburn, James; Strube, Michael J; Commean, Paul; Johnson, Jeffrey E; Cheuy, Victor; Sinacore, David R
2016-02-01
Diabetes mellitus related medial column foot deformity is a major contributor to ulceration and amputation. However, little is known about the relationship between medial column alignment and function and the integrity of the soft tissues that support and move the medial column. The purposes of this study were to determine the predictors of medial column alignment and function in people with diabetes and peripheral neuropathy. 23 participants with diabetes and neuropathy had radiographs, heel rise kinematics, magnetic resonance imaging and isokinetic muscle testing to measure: 1) medial column alignment (Meary's angle--the angle between the 1st metatarsal longitudinal axis and the talar head and neck), 2) medial column function (forefoot relative to hindfoot plantarflexion during heel rise), 3) intrinsic foot muscle and fat volume, ratio of posterior tibialis to flexor digitorum tendon volume, 4) plantar fascia function (Meary's angle change from toes flat to extended) and 5) plantarflexor peak torque. Predictors of medial column alignment and function were determined using simultaneous entry multiple regression. Posterior tibialis to flexor digitorum tendon volume ratio and intrinsic foot muscle volume were significant predictors of medial column alignment (P<.05), accounting for 44% of the variance. Intrinsic foot fat volume and plantarflexor peak torque were significant predictors of medial column function (P<.05), accounting for 37% of the variance. Deterioration of medial column supporting structures predicted alignment and function. Prospective research is required to monitor alignment, structure, and function over time to inform early intervention strategies to prevent deformity, ulceration, and amputation. Copyright © 2015 Elsevier Ltd. All rights reserved.
Ozdinc, Sevgi Anar; Turan, Fatma Nesrin
2016-07-01
To investigate the effects of ballet training on foot structure and the formation of the medial longitudinal arc in childhood, and the association of body mass index with structural change secondary to ballet training. This study was conducted at Öykü Ballet and Dance School and Trakya University, Edirne, Turkey, from September 2007 to November 2008, and comprised girl students who were taking ballet classes, and a group of those who were not taking such who acted as the controls. Static footprints of both feet of all participants were taken with an ink paedogram. Parameters evaluated from footprints included foot length, metatarsal width, heel width and medial longitudinal arch. The relationship between the parameters, the ballet starting age, training duration and body mass index was investigated. Of the 67 participants, there were 36(53.7%) in the experimental group and 31(48.3%) in the control group. The difference between age, height, weight and body mass index between the two groups was insignificant (p>0.05). The average ballet starting age was 6.47±1.55 years and duration was 4.36±2.002 years. Positive correlations were found between body mass index and foot length, metatarsal width, heel width, medial longitudinal arch contact width and halluxvalgus angle; between ballet starting age and metatarsal width, heel width; between duration of training and foot length, metatarsal width and hallux valgus angle (p?0.05 each). Evidence supporting the education in children on foot anthropometric measurements and medial longitudinal arc development could not be found.
Rui, Jing; Runge, M Brett; Spinner, Robert J; Yaszemski, Michael J; Windebank, Anthony J; Wang, Huan
2014-10-01
Video-assisted gait kinetics analysis has been a sensitive method to assess rat sciatic nerve function after injury and repair. However, in conduit repair of sciatic nerve defects, previously reported kinematic measurements failed to be a sensitive indicator because of the inferior recovery and inevitable joint contracture. This study aimed to explore the role of physiotherapy in mitigating joint contracture and to seek motion analysis indices that can sensitively reflect motor function. Data were collected from 26 rats that underwent sciatic nerve transection and conduit repair. Regular postoperative physiotherapy was applied. Parameters regarding step length, phase duration, and ankle angle were acquired and analyzed from video recording of gait kinetics preoperatively and at regular postoperative intervals. Stride length ratio (step length of uninjured foot/step length of injured foot), percent swing of the normal paw (percentage of the total stride duration when the uninjured paw is in the air), propulsion angle (toe-off angle subtracted by midstance angle), and clearance angle (ankle angle change from toe off to midswing) decreased postoperatively comparing with baseline values. The gradual recovery of these measurements had a strong correlation with the post-nerve repair time course. Ankle joint contracture persisted despite rigorous physiotherapy. Parameters acquired from a 2-dimensional motion analysis system, that is, stride length ratio, percent swing of the normal paw, propulsion angle, and clearance angle, could sensitively reflect nerve function impairment and recovery in the rat sciatic nerve conduit repair model despite the existence of joint contractures.
16 CFR Table 2 to Part 1512 - Minimum Candlepower per Incident Foot-Candle for Clear Reflector 1
Code of Federal Regulations, 2010 CFR
2010-01-01
... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Minimum Candlepower per Incident Foot-Candle for Clear Reflector 1 2 Table 2 to Part 1512 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION..., and side reflectors; entrance angle in degrees 30 left/right 40 left/right 50 left/right 0.2 8.0 7.0 6...
Bade, Michael B.; Aaron, Katie
2016-01-01
ABSTRACT Background Clinicians are interested in the foot strike pattern (FSP) in runners because of the suggested relationship between the strike pattern and lower extremity injury. Purpose The purpose of this study was to assess the ability of collegiate cross-country runners and recreational runners to self-report their foot strike pattern during running. Study Design Cross-sectional Study Methods Twenty-three collegiate cross-country and 23 recreational runners voluntarily consented to participate. Inclusion criteria included running at least 18 miles per week, experience running on a treadmill, no history of lower extremity congenital or traumatic deformity, or acute injury three months prior to the start of the study. All participants completed a pre-test survey to indicate their typical foot strike pattern during a training run (FSPSurvey). Prior to running, reflective markers were placed on the posterior midsole and the vamp of the running shoe. A high-speed camera was used to film each runner in standing and while running at his or her preferred speed on a treadmill. The angle between the vector formed by the two reflective markers and the superior surface of the treadmill was used to calculate the foot strike angle (FSA). To determine the foot strike pattern from the video data (FSPVideo), the static standing angle was subtracted from the FSA at initial contact of the shoe on the treadmill. In addition to descriptive statistics, percent agreement and Chi square analysis was used to determine distribution differences between the video analysis results and the survey. Results The results of the chi-square analysis on the distribution of the FSPSurvey in comparison to the FSPVideo were significantly different for both the XCRunners (p < .01; Chi-square = 8.77) and the REC Runners (p < .0002; Chi-square = 16.70). The cross-country and recreational runners could correctly self-identified their foot strike pattern 56.5% and 43.5% of the time, respectively. Conclusion The findings of this study suggest that the clinician cannot depend on an experienced runner to correctly self-identify their FSP. Clinicians interested in knowing the FSP of a runner should consider performing the two-dimensional video analysis described in this paper. Level of Evidence 3 PMID:27274421
Moyer, Rebecca; Birmingham, Trevor; Dombroski, Colin; Walsh, Robert; Giffin, J Robert
2017-05-01
The aim of this study was to investigate the combined and individual biomechanical effects of a valgus knee brace and a lateral wedge foot orthotic during stair ascent and descent in patients with knee osteoarthritis (OA). Thirty-five patients with varus alignment and medial knee OA were prescribed a custom valgus knee brace and lateral wedge foot orthotic. Knee angles and moments in the frontal and sagittal planes were determined from 3D gait analysis completed under four randomized conditions: (1) control (no knee brace or foot orthotic), (2) knee brace, (3) foot orthotic, and (4) combined knee brace and foot orthotic. Additional measures included the vertical ground reaction force, trunk lean, toe out and gait speed. During the combined use of a knee brace and foot orthotic, significant decreases in the knee adduction angle (2.17, 95%CI: 0.50-3.84, p=0.013) and 2nd peak EKAM (0.35, 95%CI: 0.17-0.52, p<0.001) were observed during stair descent; and significant increases in the EKFM were observed during stair ascent (0.54, 95%CI: 0.30-0.78, p<0.001) and descent (1stpk: 0.48, 95%CI: 0.15-0.80, p=0.005; 2ndpk: 0.55, 95%CI: 0.34-0.76, p<0.001). Fewer gait compensations were observed between conditions during stair descent compared to ascent, except for toe out. Findings suggest greater effects on gait when both knee brace and foot orthotic are used together, resulting in a more normal gait pattern. However, whether or not a true change in knee joint load can be inferred when using these orthoses remains unclear. Further research is required to determine the clinical importance of the observed changes. Copyright © 2017. Published by Elsevier B.V.
Can We Measure the Heel Bump? Radiographic Evaluation of Haglund's Deformity.
Bulstra, Gythe H; van Rheenen, Thijs A; Scholtes, Vanessa A B
2015-01-01
Haglund's deformity is a symptomatic posterosuperior deformity of the heel. The lateral radiograph of the ankle will show a prominent, large, posterosuperior part of the calcaneus, which can be measured using the Fowler and Philips angle (FPA, the angle between the posterior and plantar surface of the calcaneus) and the calcaneal pitch angle (CPA, the angle between the sole of the foot and the plantar part of the calcaneus). Although these angles are commonly used, these radiographic angle measurements have never shown a relationship with Haglund's deformity. In 78 patients (51% male) with symptomatic Haglund's deformity and a control group of 100 patients (41% male) with no heel complaints, we measured the FPA and CPA on weightbearing lateral radiographs of the foot. Using an unpaired t tests, no significant difference was found between the 2 groups in the FPA (p = .40). We measured a significant difference in the CPA between the Haglund group and the control group (p = .014). Subgroup analysis showed that this difference was mainly found in females (p < .00), with no significant difference seen in the males (p < .48). Females with Haglund's deformity will have a greater CPA than will females without Haglund's deformity. The CPA showed a difference between the Haglund and non-Haglund groups, although mainly in females. Although the evidence from our study is limited, it would be interesting to study the CPA further, because it implicates the verticalization of the calcaneus. This change in position results in extra traction on the Achilles tendon and can eventually cause tendinitis and bursitis. Radiographic measurement should be used as an auxiliary tool. If the calcaneus tends to change position, it would be interesting to understand this process, which could eventually lead to improvement in the treatment of Haglund's deformity. Copyright © 2015 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.
Oliveira, Nuno; Saunders, David H; Sanders, Ross H
2016-01-01
To investigate the effects of fatigue on the vertical force and kinematics of the lower limbs during maximal water polo eggbeater kicking. Twelve male water polo players maintained as high a position as possible while performing the eggbeater kick with the upper limbs raised out of the water until they were unable to keep the top of the sternum (manubrium) above water. Data comprising 27 complete eggbeater-kick cycles were extracted corresponding to 9 cycles of the initial nonfatigued (0%), 50% time point (50%), and final fatigued (100%) periods of the trial. Vertical force, foot speed, and hip-, knee-, and ankle-joint angles were calculated. Mean vertical force (0%, 212.2 N; 50%, 184.5 N; 100%, 164.3 N) progressively decreased with time. Speed of the feet (0.4 m/s), hip abduction (2.9°), and flexion (3.6°) decreased with fatigue, while hip internal rotation (3.6°) and ankle inversion (4°) increased with fatigue. Average angular velocity decreased for all joint motions. Eggbeater-kick performance decreases with fatigue. Inability to maintain foot speeds and hip and ankle actions with progressing fatigue diminishes the ability of the player to produce vertical force during the cycle. Increased internal rotation of the hip when fatigued and the large eversion/abduction of the ankle during the cycle may be predisposing factors for the prevalence of patellofemoral pain syndrome observed among eggbeater-kick performers. Appropriate training interventions that can limit the effects of fatigue on performance and injury risk should be considered.
Lateral column length in adult flatfoot deformity.
Kang, Steve; Charlton, Timothy P; Thordarson, David B
2013-03-01
In adult acquired flatfoot deformity, it is unclear whether the lateral column length shortens with progression of the deformity, whether it is short to begin with, or whether it is short at all. To our knowledge, no previous study has examined the lateral column length of patients with adult acquired flatfoot deformity compared to a control population. The purpose of our study was to compare the lateral column length in patients with and without adult acquired flatfoot deformity to see if there was a significant difference. The study was a retrospective radiographic review of 2 foot and ankle fellowship-trained orthopaedic surgeons' patients with adult flatfoot deformity. Our study population consisted of 75 patients, 85 feet (28 male, 57 female) with adult flatfoot deformity with a mean age of 64 (range, 23-93). Our control population consisted of 57 patients and 70 feet (23 male, 47 female) without flatfoot deformity with a mean age of 61 (range, 40-86 years). Weightbearing anteroposterior (AP) and lateral foot radiographs were analyzed for each patient, and the following measurements were made: medial and lateral column lengths, talonavicular uncoverage angle, talus-first metatarsal angle, calcaneal pitch angle, and medial and lateral column heights. An unpaired t test was used to analyze the measurements between the groups. Ten patients' radiographs were remeasured, and correlation coefficients were obtained to assess the reliability of the measuring techniques. For the flatfoot group, the mean medial and lateral column lengths on the AP radiograph were 108.6 mm and 95.8 mm, respectively; the mean talo-navicular uncoverage angle was 26.2 degrees; and the mean talus-first metatarsal angle was 20.0 degrees. In the control group, the mean medial and lateral column lengths on the AP radiograph were 108.8 mm and 96.5 mm, respectively; the mean talo-navicular uncoverage angle was 8.2 degrees; and the mean talus-first metatarsal angle was 7.7 degrees. On the lateral radiograph in the flatfoot group, the mean medial and lateral column lengths were 167.2 mm and 166.6 mm, respectively; the mean medial and lateral column heights were 16.0 mm and 14.7 mm, respectively; the mean calcaneal pitch angle was 15.6 degrees; and the talus-first metatarsal angle was 10.3 degrees and for the control group, the mean medial and lateral column lengths were 165.3 mm and 163.5 mm, respectively; the mean medial and lateral column heights were 22.8 mm and 13.1 mm, respectively; the mean calcaneal pitch angle was 22.4 degrees; and the talus-first metatarsal angle was -3.6 degrees. None of the differences in measurements for medial and lateral column lengths between the flatfoot and control groups achieved statistical significance. However, statistically significant differences between the 2 groups were observed in the measurements for medial and lateral column heights, talo-navicular uncoverage angle, calcaneal pitch angle, and talus-first metatarsal angle. There is no difference in lateral column lengths between patients with and without adult flatfoot deformity. The perceived shortened lateral column is likely due to forefoot abduction and hindfoot valgus deformities that are associated with adult flatfoot deformity. Level III, comparative series.
NASA Technical Reports Server (NTRS)
Kingsland, R. B.; Lockman, W. K.
1975-01-01
The results of hypersonic wind tunnel testing of an 0.0175 scale version of the vehicle 3 space shuttle configuration are presented. Temperature measurements were made on the launch configuration, orbiter plus tank, orbiter alone, tank alone, and solid rocket booster alone to provide heat transfer data. The test was conducted at free-stream Mach numbers of 5.3 and 7.3 and at free-stream Reynolds numbers of 1.5 million, 3.7 million, 5.0 million, and 7.0 million per foot. The model was tested at angles of attack from -5 deg to 20 deg and side slip angles of -5 deg and 0 deg.
Cho, Byung-Ki; Park, Kyoung-Jin; Choi, Seung-Myung; Kang, Sang-Woo; Lee, Hyung-Ki
2016-12-01
Although a ball and socket ankle deformity is usually congenital and asymptomatic, abnormal inversion and eversion mobility can result in recurrent ankle sprain and osteoarthritis. This retrospective study was performed to evaluate the clinical and radiologic outcomes of ankle fusion combined with calcaneal sliding osteotomy for severe arthritic ball and socket ankle deformity. Fourteen patients with severe arthritic ball and socket ankle deformity were followed for more than 3 years after operation. The clinical evaluation consisted of American Orthopaedic Foot & Ankle Society (AOFAS) score, Foot and Ankle Ability Measure (FAAM), visual analog scale (VAS) for pain, and subjective satisfaction score. The period to fusion and union of osteotomy, the change of hindfoot alignment angle, and complications were evaluated radiologically. AOFAS and FAAM scores were significantly improved from an average of 37.4 and 34.5 points to 74.6 and 78.5 points, respectively. VAS for pain with walking over 20 minutes was significantly improved from an average of 8.4 points to 1.9 points. The average satisfaction score of patients was 88.9 points. The difference in heel alignment angle (compared to contralateral side) was significantly improved from an average of 34.8 to 5.4 degrees. There were 2 cases of progressive arthritis in an adjacent joint and 1 case of failed fusion. Ankle fusion combined with calcaneal sliding osteotomy can be an effective operative option for ball and socket ankle deformity with advanced arthritis. In spite of increased complication rate, reliable pain relief, and restoration of gait ability through correcting hindfoot malalignment could improve the quality of life. Level IV, retrospective case series. © The Author(s) 2016.
Tong, Jasper W K; Kong, Pui W
2013-10-01
Systematic literature review with meta-analysis. To investigate the association between nonneutral foot types (high arch and flatfoot) and lower extremity and low back injuries, and to identify the most appropriate methods to use for foot classification. A search of 5 electronic databases (PubMed, Embase, CINAHL, SPORTDiscus, and ProQuest Dissertations and Theses), Google Scholar, and the reference lists of included studies was conducted to identify relevant articles. The review included comparative cross-sectional, case-control, and prospective studies that reported qualitative/quantitative associations between foot types and lower extremity and back injuries. Quality of the selected studies was evaluated, and data synthesis for the level of association between foot types and injuries was conducted. A random-effects model was used to pool odds ratio (OR) and standardized mean difference (SMD) results for meta-analysis. Twenty-nine studies were included for meta-analysis. A significant association between nonneutral foot types and lower extremity injuries was determined (OR = 1.23; 95% confidence interval [CI]: 1.11, 1.37; P<.001). Foot posture index (OR = 2.58; 95% CI: 1.33, 5.02; P<.01) and visual/physical examination (OR = 1.17; 95% CI: 1.06, 1.28; P<.01) were 2 assessment methods using distinct foot-type categories that showed a significant association with lower extremity injuries. For foot-assessment methods using a continuous scale, measurements of lateral calcaneal pitch angle (SMD, 1.92; 95% CI: 1.44, 2.39; P<.00001), lateral talocalcaneal angle (SMD, 1.36; 95% CI: 0.93, 1.80; P<.00001), and navicular height (SMD, 0.34; 95% CI: 0.16, 0.52; P<.001) showed significant effect sizes in identifying high-arch foot, whereas the navicular drop test (SMD, 0.45; 95% CI: 0.03, 0.87; P<.05) and relaxed calcaneal stance position (SMD, 0.49; 95% CI: 0.01, 0.97; P<.05) displayed significant effect sizes in identifying flatfoot. Subgroup analyses revealed no significant associations for children with flatfoot, cross-sectional studies, or prospective studies on high arch. High-arch and flatfoot foot types are associated with lower extremity injuries, but the strength of this relationship is low. Although the foot posture index and visual/physical examination showed significance, they are qualitative measures. Radiographic and navicular height measurements can delineate high-arch foot effectively, with only anthropometric measures accurately classifying flatfoot. Prognosis, level 2a.
Kim, Aram; Kretch, Kari S; Zhou, Zixuan; Finley, James M
2018-05-09
Successful negotiation of obstacles during walking relies on the integration of visual information about the environment with ongoing locomotor commands. When information about the body and environment are removed through occlusion of the lower visual field, individuals increase downward head pitch angle, reduce foot placement precision, and increase safety margins during crossing. However, whether these effects are mediated by loss of visual information about the lower extremities, the obstacle, or both remains to be seen. Here, we used a fully immersive, virtual obstacle negotiation task to investigate how visual information about the lower extremities is integrated with information about the environment to facilitate skillful obstacle negotiation. Participants stepped over virtual obstacles while walking on a treadmill with one of three types of visual feedback about the lower extremities: no feedback, end-point feedback, or a link-segment model. We found that absence of visual information about the lower extremities led to an increase in the variability of leading foot placement after crossing. The presence of a visual representation of the lower extremities promoted greater downward head pitch angle during the approach to and subsequent crossing of an obstacle. In addition, having greater downward head pitch was associated with closer placement of the trailing foot to the obstacle, further placement of the leading foot after the obstacle, and higher trailing foot clearance. These results demonstrate that the fidelity of visual information about the lower extremities influences both feed-forward and feedback aspects of visuomotor coordination during obstacle negotiation.
Methodology Report for H2SModel
2012-01-01
thermochemical) cal (thermochemical/ cm2) curie degree (angl e ) degree Fahrenheit electron volt erg erg/second foot foot- pound- force gal l... Dosimetry ) model developed by Asgharian ([7, 10]) . First, transport of H2S in the lung is modeled by the area-averaged convective-diffusion equation...performance. Technical Report DNA TR 85 52, Defense Nuclear Agency, Washington, D.C. , 1984. [10] Asgharian, B., et al. Multiple Path Particle Dosimetry
Squadrone, Roberto; Rodano, Renato; Hamill, Joseph; Preatoni, Ezio
2015-01-01
Despite the growing interest in minimalist shoes, no studies have compared the efficacy of different types of minimalist shoe models in reproducing barefoot running patterns and in eliciting biomechanical changes that make them differ from standard cushioned running shoes. The aim of this study was to investigate the acute effects of different footwear models, marketed as "minimalist" by their manufacturer, on running biomechanics. Six running shoes marketed as barefoot/minimalist models, a standard cushioned shoe and the barefoot condition were tested. Foot-/shoe-ground pressure and three-dimensional lower limb kinematics were measured in experienced rearfoot strike runners while they were running at 3.33 m · s⁻¹ on an instrumented treadmill. Physical and mechanical characteristics of shoes (mass, heel and forefoot sole thickness, shock absorption and flexibility) were measured with laboratory tests. There were significant changes in foot strike pattern (described by the strike index and foot contact angle) and spatio-temporal stride characteristics, whereas only some among the other selected kinematic parameters (i.e. knee angles and hip vertical displacement) changed accordingly. Different types of minimalist footwear models induced different changes. It appears that minimalist footwear with lower heel heights and minimal shock absorption is more effective in replicating barefoot running.
Tu, Shu-Qiang; Huang, Ke-Di; Shuai, Yong-Ming; Xu, Nan-Yun; Yuan, Qiu-Wen; Guo, Jian
2012-06-01
To study the curative effects of close nail-pry reduction and internal fixation with hollow screws for treatment of linguiform calcaneus fracture. From May 2006 to October 2009,32 patients (35 feet) with linguiform calcaneus fracture were treated by close nail-pry reduction and internal fixation with hollow screws, including 23 males and 9 females ranging in age from 25 to 46 years, with a mean of 37.6 years. According to Paley classification, 3 cases were Paley II a, and 29 cases were Paley II b. All cases were close fractures. The time from injury to operation was 3 to 10 days after most swelling subsided. Böhler angle and Gissane angle were measured by X-ray before and after operation. The therapeutic effect was assessed according to ZHANG Tie-liang's foot score. All the patients were followed-up for 6 to 18 months, with a mean of 12 months. All fractures gained bone healing. The time of fracture healing averaged 12 months. The fractures healed completely and no infection occurred. According to ZHANG Tie-liang's foot scale, the postoperative function was excellent in 18 feet, good in 10 feet, moderate in 5 feet and poor in 2 feet. The Böhler angle and Gissane angle were significant improved after treatment (P < 0.01). The surgical method of close nail-pry reduction and internal fixation with hollow screws for treatment of linguiform calcaneus fracture can regain the foot function, with minimal injury, fewer complications, earlier recovery and lower costs.
COMPARING 3D FOOT SHAPE MODELS BETWEEN TAIWANESE AND JAPANESE FEMALES.
Lee, Yu-Chi; Kouchi, Makiko; Mochimaru, Masaaki; Wang, Mao-Jiun
2015-06-01
This study compares foot shape and foot dimensions between Taiwanese and Japanese females. One hundred Taiwanese and 100 Japanese female 3D foot scanning data were used for comparison. To avoid the allometry effect, data from 23 Taiwanese and 19 Japanese with foot length between 233 to 237 mm were used for shape comparison. Homologous models created for the right feet of the 42 subjects were analyzed by Multidimensional Scaling. The results showed that there were significant differences in the forefoot shape between the two groups, and Taiwanese females had slightly wider feet with straighter big toe than Japanese females. The results of body and foot dimension comparison indicated that Taiwanese females were taller, heavier and had larger feet than Japanese females, while Japanese females had significantly larger toe 1 angle. Since some Taiwanese shoemakers adopt the Japanese shoe sizing system for making shoes, appropriateness of the shoe sizing system was also discussed. The present results provide very useful information for improving shoe last design and footwear fit for Taiwanese females.
Manzi, Luigi; Villafañe, Jorge Hugo; Indino, Cristian; Tamini, Jacopo; Berjano, Pedro; Usuelli, Federico Giuseppe
2017-11-08
The purpose of this study was to investigate the test-retest reliability of the Phi angle in patients undergoing total ankle replacement (TAR) for end stage ankle osteoarthritis (OA) to assess the rotational alignment of the talar component. Retrospective observational cross-sectional study of prospectively collected data. Post-operative anteroposterior radiographs of the foot of 170 patients who underwent TAR for the ankle OA were evaluated. Three physicians measured Phi on the 170 randomly sorted and anonymized radiographs on two occasions, one week apart (test and retest conditions), inter and intra-observer agreement were evaluated. Test-retest reliability of Phi angle measurement was excellent for patients with Hintegra TAR (ICC=0.995; p<0.001) and Zimmer TAR (ICC=0.995; p<0.001) on radiographs of subjects with ankle OA. There were no significant differences in the reliability of the Phi angle measurement between patients with Hintegra vs. Zimmer implants (p>0.05). Measurement of Phi angle on weight-bearing dorsoplantar radiograph showed an excellent reliability among orthopaedic surgeons in determining the position of the talar component in the axial plane. Level II, cross sectional study. Copyright © 2017 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.
Kobayashi, Toshiki; Orendurff, Michael S.; Singer, Madeline L.; Gao, Fan; Daly, Wayne K.; Foreman, K. Bo
2016-01-01
Background Genu recurvatum (knee hyperextension) is a common issue for individuals post stroke. Ankle-foot orthoses are used to improve genu recurvatum, but evidence is limited concerning their effectiveness. Therefore, the aim of this study was to investigate the effect of changing the plantarflexion resistance of an articulated ankle-foot orthosis on genu recurvatum in patients post stroke. Methods Gait analysis was performed on 6 individuals post stroke with genu recurvatum using an articulated ankle-foot orthosis whose plantarflexion resistance was adjustable at four levels. Gait data were collected using a Bertec split-belt instrumented treadmill in a 3-dimensional motion analysis laboratory. Gait parameters were extracted and plotted for each subject under the four plantarflexion resistance conditions of the ankle-foot orthosis. Gait parameters included: a) peak ankle plantarflexion angle, b) peak ankle dorsiflexion moment, c) peak knee extension angle and d) peak knee flexion moment. A non-parametric Friedman test was performed followed by a post-hoc Wilcoxon Signed-Rank test for statistical analyses. Findings All the gait parameters demonstrated statistically significant differences among the four resistance conditions of the AFO. Increasing the amount of plantarflexion resistance of the ankle-foot orthosis generally reduced genu recurvatum in all subjects. However, individual analyses showed that the responses to the changes in the plantarflexion resistance of the AFO were not necessarily linear, and appear unique to each subject. Interpretations The plantarflexion resistance of an articulated AFO should be adjusted to improve genu recurvatum in patients post stroke. Future studies should investigate what clinical factors would influence the individual differences. PMID:27136122
NASA Technical Reports Server (NTRS)
Shinoda, Patrick M.
1996-01-01
A full-scale helicopter rotor test was conducted in the NASA Ames 80- by 120-Foot Wind Tunnel with a four-bladed S-76 rotor system. Rotor performance and loads data were obtained over a wide range of rotor shaft angles-of-attack and thrust conditions at tunnel speeds ranging from 0 to 100 kt. The primary objectives of this test were (1) to acquire forward flight rotor performance and loads data for comparison with analytical results; (2) to acquire S-76 forward flight rotor performance data in the 80- by 120-Foot Wind Tunnel to compare with existing full-scale 40- by 80-Foot Wind Tunnel test data that were acquired in 1977; (3) to evaluate the acoustic capability of the 80- by 120- Foot Wind Tunnel for acquiring blade vortex interaction (BVI) noise in the low speed range and compare BVI noise with in-flight test data; and (4) to evaluate the capability of the 80- by 120-Foot Wind Tunnel test section as a hover facility. The secondary objectives were (1) to evaluate rotor inflow and wake effects (variations in tunnel speed, shaft angle, and thrust condition) on wind tunnel test section wall and floor pressures; (2) to establish the criteria for the definition of flow breakdown (condition where wall corrections are no longer valid) for this size rotor and wind tunnel cross-sectional area; and (3) to evaluate the wide-field shadowgraph technique for visualizing full-scale rotor wakes. This data base of rotor performance and loads can be used for analytical and experimental comparison studies for full-scale, four-bladed, fully articulated rotor systems. Rotor performance and structural loads data are presented in this report.
Hoof position during limb loading affects dorsoproximal bone strains on the equine proximal phalanx.
Singer, Ellen; Garcia, Tanya; Stover, Susan
2015-07-16
Sagittal fractures of the proximal phalanx (P1) in the racehorse appear to be associated with turf racing surfaces, which are known to restrict forward slide of the foot at impact. We hypothesized that restriction of forward foot slip would result in higher P1 bone strains during metacarpophalangeal joint (MCPJ) hyperextension. Unilateral limbs from six equine cadavers were instrumented with strain gauges and bone reference markers to measure dorsoproximal P1 bone strains and MCPJ extension, collateromotion and axial rotation during in vitro limb loading to 10,500 N. By limiting movement of the distal actuator platform, three different foot conditions (forward, free, and restricted) were applied in a randomised block design. Bone reference markers, recorded by video, were analyzed to determine motion of P1 relative to MC3. Rosette strain data were reduced to principal and shear magnitudes and directions. A mixed model ANOVA determined the effect of foot position on P1 bone strains and MCPJ angles. At 10,000 N load, the restricted condition resulted in higher P1 axial compressive (p=0.015), maximum shear (p=0.043) and engineering shear (p=0.046) strains compared to the forward condition. The restricted condition had higher compressive (p=0.025) and lower tensile (p=0.043) principal strains compared to the free condition. For the same magnitude of principal or shear strains, axial rotation and collateromotion angles were greatest for the restricted condition. Therefore, the increase in P1 principal compressive and shear bone strains associated with restricted foot slip indicate that alterations in foot:ground interaction may play a role in fracture occurrence in horses. Copyright © 2015 Elsevier Ltd. All rights reserved.
Boffeli, Troy J; Waverly, Brett J
2016-01-01
The long leg axial view is primarily used to evaluate the frontal plane alignment of the calcaneus in relation to the long axis of the tibia when standing. This view allows both angular measurement and assessment for the apex of varus and valgus deformity of the rearfoot and ankle with clinical utility in the preoperative, intraoperative, and postoperative settings. The frontal plane alignment of the calcaneus to the long axis of the tibia is rarely fixed in the varus or valgus position because of the inherent flexibility of the foot and ankle, which makes patient positioning critical to obtain accurate and reproducible images. Inconsistent patient positioning and imaging techniques are commonly encountered with the long leg axial view for a variety of reasons, including the lack of a standardized or validated protocol. This angle and base of gait imaging protocol involves positioning the patient to align the tibia with the long axis of the foot, which is represented by the second metatarsal. Non-weightbearing long leg axial imaging is commonly performed intraoperatively, which requires a modified patient positioning technique to capture simulated weightbearing long leg axial images. A case series is presented to demonstrate our angle and base of gait long leg axial and intraoperative simulated weightbearing long leg axial imaging protocols that can be applied throughout all phases of patient care for various foot and ankle conditions. Copyright © 2015 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.
de Kam, Digna; Roelofs, Jolanda M B; Geurts, Alexander C H; Weerdesteyn, Vivian
2018-01-01
To determine the predictive value of leg and trunk inclination angles at stepping-foot contact for the capacity to recover from a backward balance perturbation with a single step in people after stroke. Twenty-four chronic stroke survivors and 21 healthy controls were included in a cross-sectional study. We studied reactive stepping responses by subjecting participants to multidirectional stance perturbations at different intensities on a translating platform. In this paper we focus on backward perturbations. Participants were instructed to recover from the perturbations with maximally one step. A trial was classified as 'success' if balance was restored according to this instruction. We recorded full-body kinematics and computed: 1) body configuration parameters at first stepping-foot contact (leg and trunk inclination angles) and 2) spatiotemporal step parameters (step onset, step length, step duration and step velocity). We identified predictors of balance recovery capacity using a stepwise logistic regression. Perturbation intensity was also included as a predictor. The model with spatiotemporal parameters (perturbation intensity, step length and step duration) could correctly classify 85% of the trials as success or fail (Nagelkerke R2 = 0.61). In the body configuration model (Nagelkerke R2 = 0.71), perturbation intensity and leg and trunk angles correctly classified the outcome of 86% of the recovery attempts. The goodness of fit was significantly higher for the body configuration model compared to the model with spatiotemporal variables (p<0.01). Participant group and stepping leg (paretic or non-paretic) did not significantly improve the explained variance of the final body configuration model. Body configuration at stepping-foot contact is a valid and clinically feasible indicator of backward fall risk in stroke survivors, given its potential to be derived from a single sagittal screenshot.
Kinematic adaptations of the hindfoot, forefoot, and hallux during cross-slope walking.
Damavandi, Mohsen; Dixon, Philippe C; Pearsall, David J
2010-07-01
Despite cross-slope surfaces being a regular feature of our environment, little is known about segmental adaptations required to maintain both balance and forward locomotion. The purpose of this study was to determine kinematic adaptations of the foot segments in relation to transverse (cross-sloped) walking surfaces. Ten young adult males walked barefoot along an inclinable walkway (level, 0° and cross-slope, 10°). Kinematic adaptations of hindfoot with respect to tibia (HF/TB), forefoot with respect to hindfoot (FF/HF), and hallux with respect to forefoot (HX/FF) in level walking (LW), inclined walking up-slope (IWU), i.e., the foot at the higher elevation, and inclined walking down-slope (IWD), i.e., the foot at the lower elevation, were measured. Multivariate analysis of variance (MANOVA) for repeated measures was used to analyze the data. In the sagittal plane, the relative FF/HF and HX/FF plantar/dorsiflexion angles differed across conditions (p=0.024 and p=0.026, respectively). More importantly, numerous frontal plane alterations occurred. For the HF/TB angle, inversion of IWU and eversion of IWD was seen at heel-strike (p<0.001). This pattern reversed with IWU showing eversion and IWD inversion in early stance (p=0.024). For the FF/HF angle, significant differences were observed in mid-stance with IWD revealing inversion while IWU was everted (p<0.004). At toe-off, the pattern switched to eversion of IWD and inversion of IWU (p=0.032). The information obtained from this study enhances our understanding of the kinematics of the human foot in stance during level and cross-slope walking. Copyright © 2010 Elsevier B.V. All rights reserved.
Amerinatanzi, Amirhesam; Zamanian, Hashem; Shayesteh Moghaddam, Narges
2017-01-01
Hinge-based Ankle Foot Orthosis (HAFO) is one of the most common non-surgical solutions for the foot drop. In conventional HAFOs, the ankle joint is almost locked, and plantar flexion is restricted due to the high stiffness of the hinge mechanism. This often leads to a rigid walking gate cycle, poor muscle activity, and muscle atrophy. Since the ankle torque-angle loop has a non-linear profile, the use of a superelastic NiTi spring within the hinge, due to its nonlinear behavior, could recreate a close-to-normal stiffness of the normal ankle joint, which, in turn, could create a more natural walk. The focus of this study is to evaluate the performance of a superelastic NiTi spring versus a conventional Stainless Steel spring in a hinge mechanism of a custom-fit HAFO. To this aim, a custom-fit HAFO was fabricated via the fast casting technique. Then, motion analysis was performed for two healthy subjects (Case I and Case II): (i) subjects with bare foot; (ii) subjects wearing a conventional HAFO with no spring; (iii) subjects wearing a conventional Stainless Steel-based HAFO; and (iv) subjects wearing a NiTi spring-based HAFO. The data related to the ankle angle and the amount of moment applied to the ankle during walking were recorded using Cortex software and used for the evaluations. Finally, Finite Element Analysis (FEA) was performed to evaluate the safety of the designed HAFO. The NiTi spring offers a higher range of motion (7.9 versus 4.14 degree) and an increased level of moment (0.55 versus 0.36 N·m/kg). Furthermore, a NiTi spring offers an ankle torque-angle loop closer to that of the healthy subjects. PMID:29215571
Simulation of uphill/downhill running on a level treadmill using additional horizontal force.
Gimenez, Philippe; Arnal, Pierrick J; Samozino, Pierre; Millet, Guillaume Y; Morin, Jean-Benoit
2014-07-18
Tilting treadmills allow a convenient study of biomechanics during uphill/downhill running, but they are not commonly available and there is even fewer tilting force-measuring treadmill. The aim of the present study was to compare uphill/downhill running on a treadmill (inclination of ± 8%) with running on a level treadmill using additional backward or forward pulling forces to simulate the effect of gravity. This comparison specifically focused on the energy cost of running, stride frequency (SF), electromyographic activity (EMG), leg and foot angles at foot strike, and ground impact shock. The main results are that SF, impact shock, and leg and foot angle parameters determined were very similar and significantly correlated between the two methods, the intercept and slope of the linear regression not differing significantly from zero and unity, respectively. The correlation of oxygen uptake (V̇O2) data between both methods was not significant during uphill running (r=0.42; P>0.05). V̇O2 data were correlated during downhill running (r=0.74; P<0.01) but there was a significant difference between the methods (bias=-2.51 ± 1.94 ml min(-1) kg(-1)). Linear regressions for EMG of vastus lateralis, biceps femoris, gastrocnemius lateralis, soleus and tibialis anterior were not different from the identity line but the systematic bias was elevated for this parameter. In conclusion, this method seems appropriate for the study of SF, leg and foot angle, impact shock parameters but is less applicable for physiological variables (EMG and energy cost) during uphill/downhill running when using a tilting force-measuring treadmill is not possible. Copyright © 2014 Elsevier Ltd. All rights reserved.
Amerinatanzi, Amirhesam; Zamanian, Hashem; Shayesteh Moghaddam, Narges; Jahadakbar, Ahmadreza; Elahinia, Mohammad
2017-12-07
Hinge-based Ankle Foot Orthosis (HAFO) is one of the most common non-surgical solutions for the foot drop. In conventional HAFOs, the ankle joint is almost locked, and plantar flexion is restricted due to the high stiffness of the hinge mechanism. This often leads to a rigid walking gate cycle, poor muscle activity, and muscle atrophy. Since the ankle torque-angle loop has a non-linear profile, the use of a superelastic NiTi spring within the hinge, due to its nonlinear behavior, could recreate a close-to-normal stiffness of the normal ankle joint, which, in turn, could create a more natural walk. The focus of this study is to evaluate the performance of a superelastic NiTi spring versus a conventional Stainless Steel spring in a hinge mechanism of a custom-fit HAFO. To this aim, a custom-fit HAFO was fabricated via the fast casting technique. Then, motion analysis was performed for two healthy subjects (Case I and Case II): (i) subjects with bare foot; (ii) subjects wearing a conventional HAFO with no spring; (iii) subjects wearing a conventional Stainless Steel-based HAFO; and (iv) subjects wearing a NiTi spring-based HAFO. The data related to the ankle angle and the amount of moment applied to the ankle during walking were recorded using Cortex software and used for the evaluations. Finally, Finite Element Analysis (FEA) was performed to evaluate the safety of the designed HAFO. The NiTi spring offers a higher range of motion (7.9 versus 4.14 degree) and an increased level of moment (0.55 versus 0.36 N·m/kg). Furthermore, a NiTi spring offers an ankle torque-angle loop closer to that of the healthy subjects.
NASA Technical Reports Server (NTRS)
Erickson, Gary E.
2017-01-01
A wind tunnel experiment was conducted in the NASA Langley Research Center 7- by 10-Foot High Speed Tunnel to determine the effects of passive surface porosity on the subsonic vortex flow interactions about a general research fighter configuration. Flow-through porosity was applied to the leading-edge extension, or LEX, and leading-edge flaps mounted to a 65deg cropped delta wing model as a potential vortex flow control technique at high angles of attack. All combinations of porous and nonporous LEX and flaps were investigated. Wing upper surface static pressure distributions and six-component forces and moments were obtained at a free-stream Mach number of 0.20 corresponding to a Reynolds number of 1.35(106) per foot, angles of attack up to 45deg, angles of sideslip of 0deg and +/-5deg, and leading-edge flap deflections of 0deg and 30deg.
NASA Technical Reports Server (NTRS)
Petrozzi, M. T.; Milam, M. D.; Mellenthin, J. A.
1974-01-01
Experimental aerodynamic investigations were conducted in a 3.5-foot hypersonic wind tunnel. The model used for this test was a 0.010-scale of the Configuration 2 Space Shuttle Orbiter and the External Tank. Six-component aerodynamic force and moment data were recorded over an angle of attack range from -8 deg to +30 deg at 0 deg and 5 deg angles of sideslip. Data was also recorded during beta sweeps of -8 deg to +10 deg at angles of attack of -10 deg, 0 deg, and 30 deg. All testing was done at Mach 7.3. Various elevon, rudder and orbiter to external tank attaching structures and fairings were tested to determine longitudinal and lateral-directional stability characteristics. Non-metric exhaust plumes were installed during a portion of the testing to determine the effects of the main propulsion system rocket plumes.
Gender differences associated with rearfoot, midfoot, and forefoot kinematics during running.
Takabayashi, Tomoya; Edama, Mutsuaki; Nakamura, Masatoshi; Nakamura, Emi; Inai, Takuma; Kubo, Masayoshi
2017-11-01
Females, as compared with males, have a higher proportion of injuries in the foot region. However, the reason for this gender difference regarding foot injuries remains unclear. This study aimed to investigate gender differences associated with rearfoot, midfoot, and forefoot kinematics during running. Twelve healthy males and 12 females ran on a treadmill. The running speed was set to speed which changes from walking to running. Three-dimensional kinematics of rearfoot, midfoot, and forefoot were collected and compared between males and females. Furthermore, spatiotemporal parameters (speed, cadence, and step length) were measured. In the rearfoot angle, females showed a significantly greater peak value of plantarflexion and range of motion in the sagittal plane as compared with males (effect size (ES) = 1.55 and ES = 1.12, respectively). In the midfoot angle, females showed a significantly greater peak value of dorsiflexion and range of motion in the sagittal plane as compared with males (ES = 1.49 and ES = 1.71, respectively). The forefoot peak angles and ranges of motion were not significantly different between the genders in all three planes. A previous study suggested that a gender-related difference in excessive motions of the lower extremities during running has been suggested as a contributing factor to running injuries. Therefore, the present investigation may provide insight into the reason for the high incidence of foot injuries in females.
Parametric study of orthopedic insole of valgus foot on partial foot amputation.
Guo, Jun-Chao; Wang, Li-Zhen; Chen, Wei; Du, Cheng-Fei; Mo, Zhong-Jun; Fan, Yu-Bo
2016-01-01
Orthopedic insole was important for partial foot amputation (PFA) to achieve foot balance and avoid foot deformity. The inapposite insole orthosis was thought to be one of the risk factors of reamputation for foot valgus patient, but biomechanical effects of internal tissues on valgus foot had not been clearly addressed. In this study, plantar pressure on heel and metatarsal regions of PFA was measured using F-Scan. The three-dimensional finite element (FE) model of partial foot evaluated different medial wedge angles (MWAs) (0.0°-10.0°) of orthopedic insole on valgus foot. The effect of orthopedic insole on the internal bone stress, the medial ligament tension of ankle, plantar fascia tension, and plantar pressure was investigated. Plantar pressure on medial heel region was about 2.5 times higher than that of lateral region based on the F-Scan measurements. FE-predicted results showed that the tension of medial ankle ligaments was the lowest, and the plantar pressure was redistributed around the heel, the first metatarsal, and the lateral longitudinal arch regions when MWA of orthopedic insole ranged from 7.5° to 8.0°. The plantar fascias maintained about 3.5% of the total load bearing on foot. However, the internal stresses from foot bones increased. The simulation in this study would provide the suggestion of guiding optimal design of orthopedic insole and therapeutic planning to pedorthist.
Body weight and the medial longitudinal foot arch: high-arched foot, a hidden problem?
Woźniacka, R; Bac, A; Matusik, S; Szczygieł, E; Ciszek, E
2013-05-01
This study had two objectives. First, to determine the prevalence of hollow (high-arched) and flat foot among primary school children in Cracow (Poland). Second, to evaluate the relationship between the type of medial longitudinal arch (MLA; determined by the Clarke's angle) and degree of fatness. The prevalence of underweight, overweight, and obesity was determined by means of IOTF cut-offs with respect to age and gender. A sample of 1,115 children (564 boys and 551 girls) aged between 3 and 13 years was analyzed. In all age groups, regardless of gender, high-arched foot was diagnosed in the majority of children. A distinct increase in the number of children with high-arched foot was observed between 7- and 8-year olds. Regardless of the gender, high-arched foot was more common among underweight children. In the group of obese children, the biggest differences were attributed to gender. High-arched foot was the most frequently observed among boys. In all gender and obesity level groups, the flat foot was more common among boys than among girls. High-arched foot is the most common foot defect among children 3-13 years old regardless of gender. Flat foot is least frequently observed in children 3-13 years old. A statistic correlation between MLA and adiposity is observed. Stronger correlation is observed among girls.
Hazari, Animesh; Maiya, Arun G; N, Shivashankara K
2018-02-01
A kinetic change in thefoot like altered plantar pressure is the most common etiological risk factor for causing foot ulcers among people with diabetes mellitus. Kinematic alterations in joint angle and spatiotemporal parameters of the gait have also been frequently observed in participants with diabetes peripheral neuropathy. Diabetes peripheral neuropathy is the most common long-term standing complication of type 2 diabetes mellitus. It leads to various micro and macrovascular related complication of the foot. There is a gap in theliteraturefor biomechanical evaluation and assessment in type 2 diabetes mellitus with peripheral neuropathy in Indian population. The aim of the study was to assess and determine the biomechanical changes including kinetics and kinematics of foot among diabetic peripheral neuropathy. The cross-sectional study was conducted at Diabetic Foot Clinic, Kasturba Hospital, Manipal University, Manipal, Karnataka, India. A total of 120 participants with type 2 diabetes mellitus and peripheral neuropathywere recruited under the purposive sampling method. Participants with any active ulceration or amputation were excluded from the study. The mean age, height, weight, body mass index, duration of diabetes was 57±14 year, 164±11cm, 61±18kg, 24± 3, 12±7 year respectively. There were significant changes in overall biomechanical profile along with clinical manifestations of diabetes peripheral neuropathy.The regression analysis showed statistical significance for dynamic maximum plantar pressure at forefoot with age, weight, height, duration of diabetes, body mass index, knee & ankle joint angle at toe-off phase of gait cycle,pinprick sensation and ankle reflex (R=.71,R =.55, F (12, 108)=521.9 kPa, p=.002) Conclusions: From the present study, we conclude that people with type 2 diabetes mellitus and peripheral neuropathy have significant changes in their foot kinetics and kinematicsparameters. Therefore, they could be at higher risk of foot ulceration with underlying neuropathy and biomechanically associated problems.
Tanigawa, Makoto; Stein, Jason; Park, John; Kosa, Peter; Cortese, Irene; Bielekova, Bibiana
2017-01-01
While magnetic resonance imaging contrast-enhancing lesions represent an excellent screening tool for disease-modifying treatments in relapsing-remitting multiple sclerosis (RRMS), this biomarker is insensitive for testing therapies against compartmentalized inflammation in progressive multiple sclerosis (MS). Therefore, alternative sensitive outcomes are needed. Using machine learning, clinician-acquired disability scales can be combined with timed measures of neurological functions such as walking speed (e.g. 25-foot walk; 25FW) or fine finger movements (e.g. 9-hole peg test; 9HPT) into sensitive composite clinical scales, such as the recently developed combinatorial, weight-adjusted disability scale (CombiWISE). Ideally, these complementary simplified measurements of certain neurological functions could be performed regularly at patients' homes using smartphones. We asked whether tests amenable to adaptation to smartphone technology, such as finger and foot tapping have comparable sensitivity and specificity to current non-clinician-acquired disability measures. We observed that finger and foot tapping can differentiate RRMS and progressive MS in a cross-sectional study and can also measure yearly and two-year disease progression in the latter, with better power (based on z-scores) in comparison to currently utilized 9HPT and 25FW. Replacing the 9HPT and 25FW with simplified tests broadly adaptable to smartphone technology may enhance the power of composite scales for progressive MS.
Walking performance in people with diabetic neuropathy: benefits and threats.
Kanade, R V; van Deursen, R W M; Harding, K; Price, P
2006-08-01
Walking is recommended as an adjunct therapy to diet and medication in diabetic patients, with the aim of improving physical fitness, glycaemic control and body weight reduction. Therefore we evaluated walking activity on the basis of capacity, performance and potential risk of plantar injury in the diabetic population before it can be prescribed safely. Twenty-three subjects with diabetic neuropathy (DMPN) were compared with 23 patients with current diabetic foot ulcers, 16 patients with partial foot amputations and 22 patients with trans-tibial amputations. The capacity for walking was measured using a total heart beat index (THBI). Gait velocity and average daily strides were measured to assess the performance of walking, and its impact on weight-bearing was studied using maximum peak pressure. THBI increased (p<0.01) and gait velocity and daily stride count fell (p<0.001 for both) with progression of foot complications. The maximum peak pressures over the affected foot of patients with diabetic foot ulcers (p<0.05) and partial foot amputations (p<0.01) were higher than in the group with DMPN. On the contralateral side, the diabetic foot ulcer group showed higher maximum peak pressure over the total foot (p<0.05), and patients with partial foot amputations (p<0.01) and trans-tibial amputations (p<0.05) showed higher maximum peak pressure over the heel. Walking capacity and performance decrease with progression of foot complications. Although walking is recommended to improve fitness, it cannot be prescribed in isolation, considering the increased risk of plantar injury. For essential walking we therefore recommend the use of protective footwear. Walking exercise should be supplemented by partial or non-weight-bearing exercises to improve physical fitness in diabetic populations.
16 CFR Table 1 to Part 1512 - Minimum Candlepower per Incident Foot-Candle for Clear Reflector 1
Code of Federal Regulations, 2014 CFR
2014-01-01
..., and side reflectors; entrance angle in degrees 0 10 up/down 20 left/right Pedal reflectors; entrance angle in degrees 0 10 up/down 20 left/right 0.2 27.0 18.0 9.0 7.5 6.0 3.0 0.3 6.0 4.8 2.4 1.5 .28 .20...
16 CFR Table 1 to Part 1512 - Minimum Candlepower per Incident Foot-Candle for Clear Reflector 1
Code of Federal Regulations, 2011 CFR
2011-01-01
..., and side reflectors; entrance angle in degrees 0 10 up/down 20 left/right Pedal reflectors; entrance angle in degrees 0 10 up/down 20 left/right 0.2 27.0 18.0 9.0 7.5 6.0 3.0 0.3 6.0 4.8 2.4 1.5 .28 .20...
16 CFR Table 1 to Part 1512 - Minimum Candlepower per Incident Foot-Candle for Clear Reflector 1
Code of Federal Regulations, 2010 CFR
2010-01-01
..., and side reflectors; entrance angle in degrees 0 10 up/down 20 left/right Pedal reflectors; entrance angle in degrees 0 10 up/down 20 left/right 0.2 27.0 18.0 9.0 7.5 6.0 3.0 0.3 6.0 4.8 2.4 1.5 .28 .20...
16 CFR Table 1 to Part 1512 - Minimum Candlepower per Incident Foot-Candle for Clear Reflector 1
Code of Federal Regulations, 2013 CFR
2013-01-01
..., and side reflectors; entrance angle in degrees 0 10 up/down 20 left/right Pedal reflectors; entrance angle in degrees 0 10 up/down 20 left/right 0.2 27.0 18.0 9.0 7.5 6.0 3.0 0.3 6.0 4.8 2.4 1.5 .28 .20...
16 CFR Table 1 to Part 1512 - Minimum Candlepower per Incident Foot-Candle for Clear Reflector 1
Code of Federal Regulations, 2012 CFR
2012-01-01
..., and side reflectors; entrance angle in degrees 0 10 up/down 20 left/right Pedal reflectors; entrance angle in degrees 0 10 up/down 20 left/right 0.2 27.0 18.0 9.0 7.5 6.0 3.0 0.3 6.0 4.8 2.4 1.5 .28 .20...
A kinematic method for footstrike pattern detection in barefoot and shod runners.
Altman, Allison R; Davis, Irene S
2012-02-01
Footstrike patterns during running can be classified discretely into a rearfoot strike, midfoot strike and forefoot strike by visual observation. However, the footstrike pattern can also be classified on a continuum, ranging from 0% to 100% (extreme rearfoot to extreme forefoot) using the strike index, a measure requiring force plate data. When force data are not available, an alternative method to quantify the strike pattern must be used. The purpose of this paper was to quantify the continuum of foot strike patterns using an easily attainable kinematic measure, and compare it to the strike index measure. Force and kinematic data from twenty subjects were collected as they ran across an embedded force plate. Strike index and the footstrike angle were identified for the four running conditions of rearfoot strike, midfoot strike and forefoot strike, as well as barefoot. The footstrike angle was calculated as the angle of the foot with respect to the ground in the sagittal plane. Results indicated that the footstrike angle was significantly correlated with strike index. The linear regression model suggested that strike index can be accurately estimated, in both barefoot and shod conditions, in the absence of force data. Copyright © 2011 Elsevier B.V. All rights reserved.
Mitani, Yasuhiro
2017-01-01
[Purpose] To investigate the gender-related differences in lower limb alignment, range of joint motion, and history of lower limb sports injuries in Japanese university athletes. [Subjects and Methods] The subjects were 224 Japanese university athletes (154 males and 70 females). The quadriceps angle (Q-angle), arch height index, and ranges of internal and external rotation of the hip joints were measured. History of lower limb sports injury was surveyed using a questionnaire. [Results] Females had a significantly higher Q-angle and hip joint internal rotation angle and a significantly lower arch height index than males. The survey revealed that a significantly higher proportion of females had a history of lower limb sports injuries, and that the proportion of those with a history of foot/ankle injuries was particularly high. [Conclusion] These results suggested that females experience more lower limb sports injuries than males, and that a large proportion of these injuries involve the foot/ankle. Reduced lower limb alignment and increased range of joint motion in females may be risk factors for injury because they lead to increased physical stress being exerted on the lower legs during sporting activities.
Effect of Human Movement on Galvanic Intra-Body Communication during Single Gait Cycle
NASA Astrophysics Data System (ADS)
Ibrahim, I. W.; Razak, A. H. A.; Ahmad, A.; Salleh, M. K. M.
2015-11-01
Intra-body communication (IBC) is a communication system that uses human body as a signal transmission medium. From previous research, two coupling methods of IBC were concluded which are capacitive coupling and galvanic coupling. This paper investigates the effect of human movement on IBC using the galvanic coupling method. Because the human movement is control by the limb joint, the knee flexion angle during gait cycle was used to examine the influence of human movement on galvanic coupling IBC. The gait cycle is a cycle of people walking that start from one foot touch the ground till that foot touch the ground again. Frequency range from 300 kHz to 200MHz was swept in order to investigate the signal transmission loss and the result was focused on operating frequency 70MHz to 90MHz. Results show that the transmission loss varies when the knee flexion angle increased. The highest loss of signal at frequency range between 70MHz to 90 MHz was 69dB when the knee flexion angle is 50° and the minimum loss was 51dB during the flexion angle is 5°.
Assessment of Foot Shape in Children and Adolescents with Intellectual Disability: A Pilot Study.
Wolan-Nieroda, Andżelina; Guzik, Agnieszka; Bazarnik-Mucha, Katarzyna; Rachwał, Maciej; Drzał-Grabiec, Justyna; Szeliga, Ewa; Walicka-Cupryś, Katarzyna
2018-04-11
BACKGROUND Available publications provide little evidence pertaining to assessment of foot shape in children with intellectual disability. The aim of this study was to assess the parameters of foot shape in children and adolescents with intellectual disability and to evaluate the relationship between the degree of disability and these parameters. MATERIAL AND METHODS The study involved 90 individuals aged 7-15 years, including 45 subjects with mild and moderate levels of intellectual disability (study group) and 45 peers with normal intellectual development (control group). Each participant was subjected to photogrammetric assessment of foot shape based on the projection moire effect. RESULTS Analysis of the relationship between the disability level and the assessed parameters showed that the length of the right (p=0.006) and left (p=0.004) foot, as well as Wejsflog's rate for the right (p<0.001) and left (p<0.001) foot, were significantly higher among children with mild disability, whereas GAMMA angle of the right (p=0.028) and left (p=0.006) foot was significantly higher among children with moderate disability. CONCLUSIONS The findings show a significant relationship between the degree of disability and the assessed foot parameters. Significant differences between the subjects with intellectual disability and the control group were identified in the basic parameters defining foot structure.
Barton, C J; Menz, H B; Crossley, K M
2011-03-01
Patellofemoral pain syndrome (PFPS) often results in reduced functional performance. There is growing evidence for the use of foot orthoses to treat this multifactorial condition. In this study, the immediate effects of foot orthoses on functional performance and the association of foot posture and footwear with improvements in function were evaluated. Fifty-two individuals with PFPS (18-35 years) were prescribed prefabricated foot orthoses (Vasyli Pro; Vasyli International, Labrador, Australia). Functional outcome measures evaluated included the change in (1) pain and (2) ease of a single-leg squat on a five-point Likert scale, and change in the number of (3) pain-free step downs and (4) single-leg rises from sitting. The association of foot posture using the Foot Posture Index, navicular drop and calcaneal angle relative to subtalar joint neutral; and the footwear motion control properties scale score with improved function were evaluated using Spearman's ρ statistics. Prefabricated foot orthoses produced significant improvements (p<0.05) for all functional outcome measures. A more pronated foot type and poorer footwear motion control properties were found to be associated with reduced pain during the single-leg squat and improvements in the number of pain-free single-leg rises from sitting when wearing foot orthoses. In addition, a more pronated foot type was also found to be associated with improved ease of completing a single-leg squat when wearing foot orthoses. Prefabricated foot orthoses provide immediate improvements in functional performance, and these improvements are associated with a more pronated foot type and poorer footwear motion control properties.
Biomechanical and clinical factors related to stage I posterior tibial tendon dysfunction.
Rabbito, Melissa; Pohl, Michael B; Humble, Neil; Ferber, Reed
2011-10-01
Case control. To investigate differences in arch height, ankle muscle strength, and biomechanical factors in individuals with stage I posterior tibial tendon dysfunction (PTTD) in comparison to healthy individuals. PTTD is a progressive condition, so early recognition and treatment are essential to help delay or reverse the progression. However, no previous studies have investigated stage I PTTD, and no single study has measured static anatomical structure, muscle strength, and gait mechanics in this population. Twelve individuals with stage I PTTD and 12 healthy, age- and gender-matched control subjects, who were engaged in running-related activities, participated in this study. Measurements of arch height index, maximum voluntary ankle invertor muscle strength, and 3-dimensional rearfoot and medial longitudinal arch kinematics during walking were obtained. The runners with PTTD demonstrated significantly lower seated arch height index (P = .02) and greater (P = .03) and prolonged (P = .05) peak rearfoot eversion angle during gait, compared to the healthy runners. No differences were found in standing arch height index values (P = .28), arch rigidity index (P = .06), ankle invertor strength (P = .49), or peak medial longitudinal arch values (P = .49) between groups. The increased foot pronation is hypothesized to place greater strain on the posterior tibialis muscle, which may partially explain the progressive nature of this condition.
A portable system for foot biomechanical analysis during gait.
Samson, William; Sanchez, Stéphane; Salvia, Patrick; Jan, Serge Van Sint; Feipel, Véronique
2014-07-01
Modeling the foot is challenging due to its complex structure compared to most other body segments. To analyze the biomechanics of the foot, portable devices have been designed to allow measurement of temporal, spatial, and pedobarographic parameters. The goal of this study was to design and evaluate a portable system for kinematic and dynamic analysis of the foot during gait. This device consisted of a force plate synchronized with four cameras and integrated into a walkway. The complete system can be packaged for transportation. First, the measurement system was assessed using reference objects to evaluate accuracy and precision. Second, nine healthy participants were assessed during gait trials using both the portable and Vicon systems (coupled with a force plate). The ankle and metatarsophalangeal (MP) joint angles and moments were computed, as well as the ground reaction force (GRF). The intra- and inter-subject variability was analyzed for both systems, as well as the inter-system variation. The accuracy and precision were, respectively 0.4 mm and 0.4 mm for linear values and 0.5° and 0.6° for angular values. The variability of the portable and Vicon systems were similar (i.e., the inter-system variability never exceeded 2.1°, 0.081 Nmkg(-1) and 0.267 Nkg(-1) for the angles, moments and GRF, respectively). The inter-system differences were less than the inter-subject variability and similar to the intra-subject variability. Consequently, the portable system was considered satisfactory for biomechanical analysis of the foot, outside of a motion analysis laboratory. Copyright © 2014 Elsevier B.V. All rights reserved.
A geometric analysis of hallux valgus: correlation with clinical assessment of severity
Piqué-Vidal, Carlos; Vila, Joan
2009-01-01
Background Application of plane geometry to the study of bunion deformity may represent an interesting and novel approach in the research field of hallux valgus. For the purpose of contributing to development of a different perspective in the assessment of hallux valgus, this study was conducted with three objectives: a) to determine the position on the intersection point of the perpendicular bisectors of the longitudinal axes of the first metatarsal and proximal phalanx (IP), b) to correlate the location of this point with hallux valgus deformity according to angular measurements and according to visual assessment of the severity carried out by three independent observers, and c) to assess whether this IP correlated with the radius of the first metatarsophalangeal arc circumference. Methods Measurements evaluated were intermetatarsal angle (IMA), hallux valgus angle (HVA), and proximal phalangeal articular angle (PPAA). The Autocad® program computed the location of the IP inside or outside of the foot. Three independent observers rated the severity of hallux valgus in photographs using a 100-mm visual analogue scale (VAS). Results Measurements of all angles except PPAA showed significantly lower values when the IP was located out of the foot more distantly and vice versa, significantly higher values for severe deformities in which the IP was found inside the foot (p < 0.001). The IP correlated significantly with VAS scores and with the length of the radius of the circle that included the first metatarsophalangeal arc circumference (p < 0.001) Conclusion The IP is a useful indicator of hallux valgus deformity because correlated significantly with IMA and HVA measurements, VAS scores obtained by visual inspection of the degree of deformity, and location of the center of the first metatarsophalangeal arc circumference. PMID:19442286
An investigation of rugby scrimmaging posture and individual maximum pushing force.
Wu, Wen-Lan; Chang, Jyh-Jong; Wu, Jia-Hroung; Guo, Lan-Yuen
2007-02-01
Although rugby is a popular contact sport and the isokinetic muscle torque assessment has recently found widespread application in the field of sports medicine, little research has examined the factors associated with the performance of game-specific skills directly by using the isokinetic-type rugby scrimmaging machine. This study is designed to (a) measure and observe the differences in the maximum individual pushing forward force produced by scrimmaging in different body postures (3 body heights x 2 foot positions) with a self-developed rugby scrimmaging machine and (b) observe the variations in hip, knee, and ankle angles at different body postures and explore the relationship between these angle values and the individual maximum pushing force. Ten national rugby players were invited to participate in the examination. The experimental equipment included a self-developed rugby scrimmaging machine and a 3-dimensional motion analysis system. Our results showed that the foot positions (parallel and nonparallel foot positions) do not affect the maximum pushing force; however, the maximum pushing force was significantly lower in posture I (36% body height) than in posture II (38%) and posture III (40%). The maximum forward force in posture III (40% body height) was also slightly greater than for the scrum in posture II (38% body height). In addition, it was determined that hip, knee, and ankle angles under parallel feet positioning are factors that are closely negatively related in terms of affecting maximum pushing force in scrimmaging. In cross-feet postures, there was a positive correlation between individual forward force and hip angle of the rear leg. From our results, we can conclude that if the player stands in an appropriate starting position at the early stage of scrimmaging, it will benefit the forward force production.
Pressure distributions for a rectangular supersonic inlet at subsonic speeds
NASA Technical Reports Server (NTRS)
Fuller, D. E.
1976-01-01
Pressure distribution data are provided for a supersonic rectangular inlet at subsonic speeds. Variations in cowl and ramp geometry as well as sideplate sweep were investigated. Tests were made in the Langley 16-foot transonic tunnel and the Langley high speed 7- by 10-foot tunnel for Mach numbers of 0.6, 0.7, and 0.8. Angles of attack investigated were 0 deg, 4 deg, and 8 deg for a range of mass flow ratios.
Optimal foot shape for a passive dynamic biped.
Kwan, Maxine; Hubbard, Mont
2007-09-21
Passive walking dynamics describe the motion of a biped that is able to "walk" down a shallow slope without any actuation or control. Instead, the walker relies on gravitational and inertial effects to propel itself forward, exhibiting a gait quite similar to that of humans. These purely passive models depend on potential energy to overcome the energy lost when the foot impacts the ground. Previous research has demonstrated that energy loss at heel-strike can vary widely for a given speed, depending on the nature of the collision. The point of foot contact with the ground (relative to the hip) can have a significant effect: semi-circular (round) feet soften the impact, resulting in much smaller losses than point-foot walkers. Collisional losses are also lower if a single impulse is broken up into a series of smaller impulses that gradually redirect the velocity of the center of mass rather than a single abrupt impulse. Using this principle, a model was created where foot-strike occurs over two impulses, "heel-strike" and "toe-strike," representative of the initial impact of the heel and the following impact as the ball of the foot strikes the ground. Having two collisions with the flat-foot model did improve efficiency over the point-foot model. Representation of the flat-foot walker as a rimless wheel helped to explain the optimal flat-foot shape, driven by symmetry of the virtual spoke angles. The optimal long period foot shape of the simple passive walking model was not very representative of the human foot shape, although a reasonably anthropometric foot shape was predicted by the short period solution.
The effect of patient migration in bed on torso elevation.
Wiggermann, Neal; Kotowski, Susan; Davis, Kermit; VanGilder, Catherine
2015-01-01
Elevating the hospital head of bed (HOB) to at least 30° is recommended practice to reduce the risk of ventilator-associated pneumonia (VAP) in mechanically ventilated patients. However, this common practice prescribes the position of the bed and not of the patient, which could be significantly different. The aim of this research was to determine the relationship between patient migration in bed and anatomic torso angle. Ten healthy participants were positioned in a hospital bed that was raised from flat to 30° and 45° HOB elevations. Prior to bed movement, participants were aligned to different locations along the length of the bed to represent different amounts of migration. A motion capture system was used to measure torso angle and migration toward the foot of the bed. The relationship between torso angle and migration was estimated by linear regression. Patient migration resulted in lower torso angles for both 30° and 45° HOB articulations. A migration of 10 cm resulted in a loss of 9.1° and 13.0° of torso angle for HOB articulations of 30° and 45°, respectively (for 30° articulations: (Equation is included in full-text article.)= -0.91, R = .96; for 45° articulations: (Equation is included in full-text article.)= -1.30, R = .98). Migration toward the foot of the bed flattens the torso. To maintain a torso angle that is likely to protect against VAP, healthcare providers need to manage both HOB angle and migration. Protocols and equipment that minimize patient migration will help support effective clinical practice. Future research on patient migration, as it relates to VAP or other outcomes, should measure patient torso angle to allow accurate translation of the results to care practice.
Wallace, B J; Kernozek, T W; Bothwell, E C
2007-12-01
Females experience at least twice as many non-contact anterior cruciate ligament (ACL) injuries as males. The aim of this study was to investigate if males and females exhibited different characteristics while performing a modified pro-agility test. Collegiate Division III male baseball (n=14) and female softball (n=13) players performed 4 trials of a modified pro-agility task, which consisted of running toward a force platform target for 5 steps, planting their right foot, and propelling themselves off of the target with their left foot. Kinematic and kinetic parameters were compared using a multivariate analysis of variance between gender with the level of significance set at P<0.05. Males and females exhibited similar knee valgus angles. Females had a greater maximum knee extension angle (10.14 degrees vs 17.43 degrees ), and greater knee range of motion (46.12 degrees vs 40.12 degrees ). Both groups reached maximum knee flexion at 52% of stance. Females had significantly more maximum hip flexion than males (28.86 degrees vs 22.75 degrees ). Females had significantly smaller minimum internal knee varus moments than their male counterparts (1.12 Nm/kg vs 1.55 Nm/kg). Vertical ground reaction forces as a percentage of bodyweight, and stance time, were not statistically different. The female group displayed an external knee rotation angle (2.49 degrees ) during the beginning of their stance, which was significantly different than the internal rotation angle (4.11 degrees ) in the male group. Early in stance knee rotation angle was highly correlated with the lack of internal knee varus moment (males R(2)=0.75, females R(2)=0.88). Females displayed knee moments and kinematics that may place them at greater risk for ACL injury during a stop-cut task. Females should be coached to perform stop cuts with more knee flexion and a more neutral knee rotation angle upon foot contact in an effort to reduce moments that may place the ACL at risk.
Dynamic measurement of surface strain distribution on the foot during walking.
Ito, Kohta; Maeda, Kosuke; Fujiwara, Ikumi; Hosoda, Koh; Nagura, Takeo; Lee, Taeyong; Ogihara, Naomichi
2017-05-01
To clarify the mechanism underlying the development of foot disorders such as diabetic ulcers and deformities, it is important to understand how the foot surface elongates and contracts during gait. Such information is also helpful for improving the prevention and treatment of foot disorders. We therefore measured temporal changes in the strain distribution on the foot surface during human walking. Five adult male participants walked across a glass platform placed over an angled mirror set in a wooden walkway at a self-selected speed and the dorsolateral and plantar surfaces of the foot were filmed using two pairs of synchronized high-speed cameras. Three-dimensional (3D) digital image correlation was used to quantify the spatial strain distribution on the foot surface with respect to that during quiet standing. Using the proposed method, we observed the 3D patterns of foot surface strain distribution during walking. Large strain was generated around the ball on the plantar surface of the foot throughout the entire stance phase, due to the windlass mechanism. The dorsal surface around the cuboid was stretched in the late stance phase, possibly due to lateral protruding movement of the cuboid. It may be possible to use this technique to non-invasively estimate movements of the foot bones under the skin using the surface strain distribution. The proposed technique may be an effective tool with which to analyze foot deformation in the fields of diabetology, clinical orthopedics, and ergonomics. Copyright © 2017. Published by Elsevier Ltd.
Jansen, Rasmus Bo; Møller Christensen, Tomas; Bülow, Jens; Rørdam, Lene; Holstein, Per E; Lander Svendsen, Ole
2018-02-20
Charcot foot is a severe complication to diabetes mellitus, associated with diabetic neuropathy. Any long-term effects of a Charcot foot on the progress of neuropathy are still largely unexplored. The objective was to investigate whether a previous Charcot foot had any long-term effects on the progress of neuropathy. An 8.5-year follow-up case-control study of 49 individuals with diabetes mellitus, 24 of whom also had Charcot foot at baseline visit in 2005-2007. Neuropathy was assessed with a questionnaire, biothesiometry, heart rate variability and venous occlusion plethysmography. Of the 49 baseline participants, 22 were able to participate in the follow-up. Twelve had passed away in the meantime. Heart rate variability was unchanged in both groups; from 9.7 to 7.2 beats/min (p = 0.053) in the Charcot group, and 14.3 to 12.6 beats/min (p = 0.762) in the control group. Somato-sensoric neuropathy showed no difference between baseline and follow-up in the Charcot group (from 39.1 to 38.5 V) (p = 0.946), but a significantly worsened sensitivity in the control group (from 25.1 to 38.9 V) (p = 0.002). In conclusion, we found that any differences in somatic or cardial autonomic neuropathy present at baseline had disappeared at follow-up after 8.5 years.
Control of Interacting Vortex Flows at Subsonic and Transonic Speeds Using Passive Porosity
NASA Technical Reports Server (NTRS)
Erickson, Gary E.
2003-01-01
A wind tunnel experiment was conducted in the NASA Langley Research Center (LaRC) 8-foot Transonic Pressure Tunnel (TPT) to determine the effects of passive surface porosity on vortex flow interactions about a general research fighter configuration at subsonic and transonic speeds. Flow- through porosity was applied to a wind leading-edge extension (LEX) mounted to a 65 deg cropped delta wind model to promote large nose-down pitching moment increments at high angles of attack. Porosity decreased the vorticity shed from the LEX, which weakened the LEX vortex and altered the global interactions of the LEX and wing vortices at high angles of attack. Six-component forces and moments and wing upper surface static pressure distributions were obtained at free- stream Mach numbers of 0.50, 0.85, and 1.20, Reynolds number of 2.5(10(exp-6) per foot, angles of attack up to 30 deg and angles of sideslip to plus or minus 8 deg. The off-surface flow field was visualized in selected cross-planes using a laser vapor screen flow visualization technique. Test data were obtained with a centerline vertical tail and with alternate twin, wing-mounted vertical fins having 0 deg and 30 deg cant angles. In addition, the porosity of the LEX was compartmentalized to determine the sensitivity of the vortex- dominated aerodynamics to the location and level of porosity applied to the LEX.
Control of Interacting Vortex Flows at Subsonic and Transonic Speeds Using Passive Porosity
NASA Technical Reports Server (NTRS)
Erickson, Gary E.
2003-01-01
A wind tunnel experiment was conducted in the NASA Langley Research Center (LaRC) 8-Foot Transonic Pressure Tunnel (TPT) to determine the effects of passive surface porosity on vortex flow interactions about a general research fighter configuration at subsonic and transonic speeds. Flow-through porosity was applied to a wing leading-edge extension (LEX) mounted to a 65 deg cropped delta wing model to promote large nose-down pitching moment increments at high angles of attack. Porosity decreased the vorticity shed from the LEX, which weakened the LEX vortex and altered the global interactions of the LEX and wing vortices at high angles of attack. Six-component forces and moments and wing upper surface static pressure distributions were obtained at free-stream Mach numbers of 0.50, 0.85, and 1.20, Reynolds number of 2.5(10(exp 6)) per foot, angles of attack up to 30 deg, and angles of sideslip to +/- 8 deg. The off-surface flow field was visualized in selected cross-planes using a laser vapor screen flow visualization technique. Test data were obtained with a centerline vertical tail and with alternate twin, wing-mounted vertical fins having 0 deg and 30 deg cant angles. In addition, the porosity of the LEX was compartmentalized to determine the sensitivity of the vortex-dominated aerodynamics to the location and level of porosity applied to the LEX.
Yoshida, Naruto; Kunugi, Shun; Mashimo, Sonoko; Okuma, Yoshihiro; Masunari, Akihiko; Miyazaki, Shogo; Hisajima, Tatsuya; Miyakawa, Shumpei
2015-06-01
The purpose of this study is to examine the effects of different strike forms, during cutting, on knee joint angle and lower limb muscle activity. Surface electromyography was used to measure muscle activity in individuals performing cutting manoeuvres involving either rearfoot strikes (RFS) or forefoot strikes (FFS). Three-dimensional motion analysis was used to calculate changes in knee angles, during cutting, and to determine the relationship between muscle activity and knee joint angle. Force plates were synchronized with electromyography measurements to compare muscle activity immediately before and after foot strike. The valgus angle tends to be smaller during FFS cutting than during RFS cutting. Just prior to ground contact, biceps femoris, semitendinosus, and lateral head of the gastrocnemius muscle activities were significantly greater during FFS cutting than during RFS cutting; tibialis anterior muscle activity was greater during RFS cutting. Immediately after ground contact, biceps femoris and lateral head of the gastrocnemius muscle activities were significantly greater during FFS cutting than during RFS cutting; tibialis anterior muscle activity was significantly lower during FFS cutting. The results of the present study suggest that the hamstrings demonstrate greater activity, immediately after foot strike, during FFS cutting than during RFS cutting. Thus, FFS cutting may involve a lower risk of anterior cruciate ligament injury than does RFS cutting.
Andrade, R J; Freitas, S R; Vaz, J R; Bruno, P M; Pezarat-Correia, P
2015-06-01
This study aimed to determine the influence of the head, upper trunk, and foot position on the passive knee extension (PKE) torque-angle response. PKE tests were performed in 10 healthy subjects using an isokinetic dynamometer at 2°/s. Subjects lay in the supine position with their hips flexed to 90°. The knee angle, passive torque, surface electromyography (EMG) of the semitendinosus and quadriceps vastus medialis, and stretch discomfort were recorded in six body positions during PKE. The different maximal active positions of the cervical spine (neutral; flexion; extension), thoracic spine (neutral; flexion), and ankle (neutral; dorsiflexion) were passively combined for the tests. Visual analog scale scores and EMG were unaffected by body segment positioning. An effect of the ankle joint was verified on the peak torque and knee maximum angle when the ankle was in the dorsiflexion position (P < 0.05). Upper trunk positioning had an effect on the knee submaximal torque (P < 0.05), observed as an increase in the knee passive submaximal torque when the cervical and thoracic spines were flexed (P < 0.05). In conclusion, other apparently mechanical unrelated body segments influence torque-angle response since different positions of head, upper trunk, and foot induce dissimilar knee mechanical responses during passive extension. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
NASA Technical Reports Server (NTRS)
Atencio, A., Jr.; Mckie, J.
1982-01-01
A cooperative program between the Royal Aircraft Establishment (RAE), England, and the NASA Ames Research Center was initiated to compare acoustic measurements made in the RAE 24-foot wind tunnel and in the Ames 40- by 80-foot wind tunnel. The acoustic measurements were made in both facilities using the same 102 mm conical nozzle supplied by the RAE. The nozzle was tested by each organization using its respective jet test rig. The mounting hardware and nozzle exit conditions were matched as closely as possible. The data from each wind tunnel were independently analyzed by the respective organization. The results from these tests show good agreement. In both facilities, interference with acoustic measurement is evident at angles in the forward quadrant.
NASA Astrophysics Data System (ADS)
Jayanthy, A. K.; Sujatha, N.; Reddy, M. Ramasubba; Narayanamoorthy, V. B.
2014-03-01
Measuring microcirculatory tissue blood perfusion is of interest for both clinicians and researchers in a wide range of applications and can provide essential information of the progress of treatment of certain diseases which causes either an increased or decreased blood flow. Diabetic ulcer associated with alterations in tissue blood flow is the most common cause of non-traumatic lower extremity amputations. A technique which can detect the onset of ulcer and provide essential information on the progress of the treatment of ulcer would be of great help to the clinicians. A noninvasive, noncontact and whole field laser speckle contrast imaging (LSCI) technique has been described in this paper which is used to assess the changes in blood flow in diabetic ulcer affected areas of the foot. The blood flow assessment at the wound site can provide critical information on the efficiency and progress of the treatment given to the diabetic ulcer subjects. The technique may also potentially fulfill a significant need in diabetic foot ulcer screening and management.
NASA Technical Reports Server (NTRS)
Reubush, D. E.; Mercer, C. E.
1975-01-01
A wind-tunnel investigation has been made to determine the effects of nozzle interfairing modifications on the longitudinal aerodynamic characteristics of a twin-jet, variable-wing-sweep fighter model. The model was tested in the Langley 16-foot transonic tunnel at Mach numbers of 0.6 to 1.3 and angles of attack from about minus 2 deg to 6 deg and in the Langley 4-foot supersonic presure tunnel at a Mach number of 2.2 and an angle of attack of 0 deg. Compressed air was used to simulate nozzle exhaust flow at jet total-pressure ratios from 1 (jet off) to about 21. The results of this investigation show that the aircraft drag can be significantly reduced by replacing the basic interfairing with a modified interfairing.
Real-time controller for foot-drop correction by using surface electromyography sensor.
Al Mashhadany, Yousif I; Abd Rahim, Nasrudin
2013-04-01
Foot drop is a disease caused mainly by muscle paralysis, which incapacitates the nerves generating the impulses that control feet in a heel strike. The incapacity may stem from lesions that affect the brain, the spinal cord, or peripheral nerves. The foot becomes dorsiflexed, affecting normal walking. A design and analysis of a controller for such legs is the subject of this article. Surface electromyography electrodes are connected to the skin surface of the human muscle and work on the mechanics of human muscle contraction. The design uses real surface electromyography signals for estimation of the joint angles. Various-speed flexions and extensions of the leg were analyzed. The two phases of the design began with surface electromyography of real human leg electromyography signal, which was subsequently filtered, amplified, and normalized to the maximum amplitude. Parameters extracted from the surface electromyography signal were then used to train an artificial neural network for prediction of the joint angle. The artificial neural network design included various-speed identification of the electromyography signal and estimation of the angles of the knee and ankle joints by a recognition process that depended on the parameters of the real surface electromyography signal measured through real movements. The second phase used artificial neural network estimation of the control signal, for calculation of the electromyography signal to be stimulated for the leg muscle to move the ankle joint. Satisfactory simulation (MATLAB/Simulink version 2012a) and implementation results verified the design feasibility.
Foot Structure in Boys with Down Syndrome.
Puszczałowska-Lizis, Ewa; Nowak, Krzysztof; Omorczyk, Jarosław; Ambroży, Tadeusz; Bujas, Przemysław; Nosiadek, Leszek
2017-01-01
Down syndrome (DS) is associated with numerous developmental abnormalities, some of which cause dysfunctions of the posture and the locomotor system. The analysis of selected features of the foot structure in boys with DS versus their peers without developmental disorders is done. The podoscopic examination was performed on 30 boys with DS aged 14-15 years. A control group consisted of 30 age- and gender-matched peers without DS. The feet of boys with DS are flatter compared to their healthy peers. The hallux valgus angle is not the most important feature differentiating the shape of the foot in the boys with DS and their healthy peers. In terms of the V toe setting, healthy boys had poorer results. Specialized therapeutic treatment in individuals with DS should involve exercises to increase the muscle strength around the foot joints, enhancing the stabilization in the joints and proprioception. Introducing orthotics and proper footwear is also important. It is also necessary to monitor the state of the foot in order to modify undertaken therapies.
Physical management of the Charcot foot.
Crews, Ryan T; Wrobel, James S
2008-01-01
Charcot arthropathy places individuals at risk of developing diabetic foot ulcers and potentially subsequent limb amputation by means of altering the anatomy of the foot and ankle. Physical trauma is an important component to the etiology of the condition. The physical management of the Charcot foot is concerned with minimizing the stress applied to the affected foot and ankle skeletal structure. The most appropriate device is temporally dependent on the progression of the disease. At the initiation of Charcot arthropathy, care by total contact cast is recommended. As the affected bones begin to heal, use of a removable cast walker may be implemented. When the bones reach a fixed state, appropriate footwear is dictated by the degree of deformity.
Assessment of Foot Shape in Children and Adolescents with Intellectual Disability: A Pilot Study
Wolan-Nieroda, Andżelina; Bazarnik-Mucha, Katarzyna; Rachwał, Maciej; Drzał-Grabiec, Justyna; Szeliga, Ewa; Walicka-Cupryś, Katarzyna
2018-01-01
Background Available publications provide little evidence pertaining to assessment of foot shape in children with intellectual disability. The aim of this study was to assess the parameters of foot shape in children and adolescents with intellectual disability and to evaluate the relationship between the degree of disability and these parameters. Material/Methods The study involved 90 individuals aged 7–15 years, including 45 subjects with mild and moderate levels of intellectual disability (study group) and 45 peers with normal intellectual development (control group). Each participant was subjected to photogrammetric assessment of foot shape based on the projection moire effect. Results Analysis of the relationship between the disability level and the assessed parameters showed that the length of the right (p=0.006) and left (p=0.004) foot, as well as Wejsflog’s rate for the right (p<0.001) and left (p<0.001) foot, were significantly higher among children with mild disability, whereas GAMMA angle of the right (p=0.028) and left (p=0.006) foot was significantly higher among children with moderate disability. Conclusions The findings show a significant relationship between the degree of disability and the assessed foot parameters. Significant differences between the subjects with intellectual disability and the control group were identified in the basic parameters defining foot structure. PMID:29636442
New modified technique of osteotomy for hallux valgus.
Oh, I S; Kim, M K; Lee, S H
2004-12-01
To improve the technique of osteotomy for hallux valgus (bunion). 38 cases of a new modified osteotomy procedure for hallux valgus were performed for 22 patients (21 women and one man). During a 3-year (range, 2-5 years) follow-up, the patients underwent physical examination; and their American Orthopedic Foot and Ankle Society hallux-metatarso-phalangeal-interphalangeal scale scores and standard foot radiographic measurements were recorded. 20 of the 22 patients (38 cases) had no pain, achieved good cosmesis, and were completely satisfied with the results of the operation. The remaining 2 patients had occasional mild discomfort. The mean hallux-metatarso-phalangeal-interphalangeal scale score was 93 points (range, 78-100 points). The mean preoperative and postoperative metatarsophalangeal angles were 34 degrees and 11 degrees, respectively. The mean postoperative reduction of the intermetatarsal angle and metatarsophalangeal angle were 6 degrees and 23 degrees, respectively. The new technique of osteotomy achieved even greater stability and accurate correction of the deformity in our 38 cases. Furthermore, it was more effective than conventional 'chevron' osteotomy in terms of correction of the deformity. Therefore, it should be used more widely.
NASA Technical Reports Server (NTRS)
Allen, E. C.
1971-01-01
Experimental aerodynamic investigations were made in the NASA/MSFC 14 x 14 inch trisonic wind tunnel on a NR-GD/C 0.0031 scale model delta wing booster (B-15B-1) and reusable nuclear stage (RNS). Three basic configurations were tested: (1) the B-15B-1 booster alone, (2) the RNS alone, and (3) the booster with the RNS mounted piggyback. Six component force and moment data were recorded for each of these configurations over an angle of attack range from -16 deg to 4 deg at zero degrees sideslip, and over an angle of sideslip range from -10 deg to 10 deg at zero and -6 degrees angle of attack. The configurations were tested over a Mach number range of 0.6 to 5.0 with a nominal Reynolds number of 6.5 million per foot except for Mach 1.2 and 3.0 where the Reynolds number were 12.4 million and 4.4 million per foot respectively.
NASA Technical Reports Server (NTRS)
Marshall, B. A.; Nichols, M. E.
1984-01-01
An experimental investigation (Test OA-309) was conducted using 0.0405-scale Space Shuttle Orbiter Model 16-0 in the North American Aerodynamics Laboratory 7.75 x 11.00-foot Lowspeed Wind Tunnel. The primary purpose was to locate and study any flow conditions or vortices that might have caused damage to the Advanced Flexible Reusable Surface Insulation (AFRSI) during the Space Transportation System STS-6 mission. A secondary objective was to evaluate vortex generators to be used for Wind Tunnel Test OS-314. Flowfield visualization was obtained by means of smoke, tufts, and oil flow. The test was conducted at Mach numbers between 0.07 and 0.23 and at dynamic pressures between 7 and 35 pounds per square foot. The angle-of-attack range of the model was -5 degrees through 35 degrees at 0 or 2 degrees of sideslip, while roll angle was held constant at zero degrees. The vortex generators were studied at angles of 0, 5, 10, and 15 degrees.
Large-scale wind tunnel tests of a sting-supported V/STOL fighter model at high angles of attack
NASA Technical Reports Server (NTRS)
Stoll, F.; Minter, E. A.
1981-01-01
A new sting model support has been developed for the NASA/Ames 40- by 80-Foot Wind Tunnel. This addition to the facility permits testing of relatively large models to large angles of attack or angles of yaw depending on model orientation. An initial test on the sting is described. This test used a 0.4-scale powered V/STOL model designed for testing at angles of attack to 90 deg and greater. A method for correcting wake blockage was developed and applied to the force and moment data. Samples of this data and results of surface-pressure measurements are presented.
NASA Technical Reports Server (NTRS)
1976-01-01
A 0.03-scale model of the 747 CAM/Orbiter was tested in an 8 x 12 foot transonic wind tunnel. Dynamic loads, pressure, and empennage flow field data were obtained using pressure transducers, strain gages, and a split film anemometer. The test variables included Mach number, angle of attack, sideslip angle, orbiter tailcone on and off, orbiter partial tailcone, orbiter nozzle air scoops, orbiter body flap angle, and orbiter elevon angle.
Gnanasundaram, Saraswathy; Ranganathan, Mohan; Das, Bhabendra Nath; Mandal, Asit Baran
2013-02-01
Foot odor and foot infection are major problems of athletes and persons with hyperhidrosis. Many shoes especially sports shoes have removable cushion insoles/foot beds for foot comfort. Polyurethane (PU) foam and elastomer have been used as cushion insole in shoes. In the present work, new insole materials based on porous viscoelastic PU sheets having hydrophilic property and antimicrobial drug coating to control foot infection and odor were developed. Bacteria and fungus that are causing infection and bad odor of the foot of athletes were isolated by microbial cell culturing of foot sweat. The surface of porous viscoelastic PU sheets was modified using hydrophilic polymers and coated with antimicrobial agent, silver sulfadiazine (SS). The surface modified PU sheets were characterized using ATR-FTIR, TGA, DSC, SEM, contact angle measurement and water absorption study. Results had shown that modified PU sheets have hydrophilicity greater than that of original PU sheet. FTIR spectra and SEM pictures confirmed modification of PU surface with hydrophilic polymers and coating with SS. Minimum inhibitory concentration studies indicated that SS has activity on all isolated bacteria of athletic foot sweat. The maximum inhibition was found for Pseudomonas (20mm) followed by Micrococci (17 mm), Diphtheroids (16 mm) and Staphylococci (12 mm). During perspiration of foot the hydrophilic polymers on PU surface will swell and release SS. Future work will confirm the application of these materials as inserts in athletic shoes. Copyright © 2012 Elsevier B.V. All rights reserved.
(YIP 10) - Bio-Inspired Interfaces for Hybrid Structures
2013-07-01
investigations are discussed below and in more details in the following sections: Bioinspired surfaces: The foot of many of insects and lizards is covered by...fabricated using the developed fabrication process. The straight micropillars were tilted ~ 27 o using ion beam irradiation with the incident angle 90 o...and treatment duration 20 min. The tilting angle is ~27 o . 2. Bioinspired Surfaces Asymmetric adhesion is used by many insects and gecko
NASA Technical Reports Server (NTRS)
Capone, Francis J.; Bare, E. Ann
1987-01-01
The aeropropulsive characteristics of an advanced twin-engine fighter aircraft designed for supersonic cruise have been studied in the Langley 16-Foot Tansonic Tunnel and the Lewis 10- by 10-Foot Supersonic Tunnel. The objective was to determine multiaxis control-power characteristics from thrust vectoring. A two-dimensional convergent-divergent nozzle was designed to provide yaw vector angles of 0, -10, and -20 deg combined with geometric pitch vector angles of 0 and 15 deg. Yaw thrust vectoring was provided by yaw flaps located in the nozzle sidewalls. Roll control was obtained from differential pitch vectoring. This investigation was conducted at Mach numbers from 0.20 to 2.47. Angle of attack was varied from 0 to about 19 deg, and nozzle pressure ratio was varied from about 1 (jet off) to 28, depending on Mach number. Increments in force or moment coefficient that result from pitch or yaw thrust vectoring remain essentially constant over the entire angle-of-attack range of all Mach numbers tested. There was no effect of pitch vectoring on the lateral aerodynamic forces and moments and only very small effects of yaw vectoring on the longitudinal aerodynamic forces and moments. This result indicates little cross-coupling of control forces and moments for combined pitch-yaw vectoring.
The Diabetic foot: A global threat and a huge challenge for Greece
Papanas, N; Maltezos, E
2009-01-01
The diabetic foot continues to be a major cause of morbidity, posing a global threat. Substantial progress has been now accomplished in the treatment of foot lesions, but further improvement is required. Treatment options may be classified into established measures (revascularisation, casting and debridement) and new modalities. All therapeutic measures should be provided by specialised dedicated multidisciplinary foot clinics. In particular, the diabetic foot is a huge challenge for Greece. There is a dramatic need to increase the number of engaged foot care teams and their resources throughout the country. It is also desirable to continue education of both physicians and general diabetic population on the magnitude of the problem and on the suitable preventative measures. At the same time, more data on the prevalence and clinical manifestations of the diabetic foot in Greece should be carefully collected. Finally, additional research should investigate feasible ways of implementing current knowledge in everyday clinical practice. PMID:20011082
NASA Technical Reports Server (NTRS)
Gorowitz, H.; White, R.; Derrico, A.
1973-01-01
Aerodynamic heating data were obtained on 0.006 scale models of four Rockwell International SSV double delta wing Orbiters in the Mach 8 variable density tunnel. A model of two previously tested Rockwell International Orbiters which are identified in the Configuration Description of this report were also tested. Orbiter surfaces were thermally mapped from the laminar through turbulent flight regimes during re-entry. Various modifications were made to model lower surfaces to determine the cause of transition in the vicinity of 3.0 million Reynolds number per foot. Re-entry data were acquired for angles of attack from 25 through 35 degrees at nominal Reynolds numbers per foot of 1.0, 2.0, 2.3, 2.5, 3.0, 3.5, 4.5 and 6.0 million utilizing the phase change paint technique. Launch data were acquired on the model upper surfaces for angles of attack of 0 and -5 degrees at nominal Reynolds numbers per foot of 3.0 and 6.0 million. A total of 70 orbiter heating runs and 6 material sample sphere runs were completed.
NASA Technical Reports Server (NTRS)
Chao, David F.; Zhang, Neng-Li
2002-01-01
As one of the basic elements of the shadowgraphy optical system, the image of the far field from the droplet implicates plentiful information on the droplet profile. An analysis of caustics by wave theory shows that a droplet with a cylindrically symmetric Gaussian-hill-type profile produces a circular directional caustic in far field, which arises from the singularities (inflection line on the surface). The sessile liquid droplets, which profiles are restricted by surface tension, usually have a 'protruding foot' where the surface inflects. Simple geometrical optics indicates that the circular caustic stemming from the surface inflection at the protruding-foot takes the shape of the outmost ring on the image of the far field. It is the diameter of the outmost ring that is used as one of the key parameters in the measurements of contact angle through the laser shadowgraphic method. Different surface characteristics of the droplets produce different type of caustics, and therefore, the shape of the caustics can be used to determine the surface property of the sessile droplets. The present paper describes the measurement method of contact angIe using the circular caustics and the estimation of the protruding-foot height through the caustic interference.
Kobayashi, Toshiki; Orendurff, Michael S; Singer, Madeline L; Gao, Fan; Foreman, K Bo
2017-06-01
Ankle-foot orthosis moment resisting plantarflexion has systematic effects on ankle and knee joint motion in individuals post-stroke. However, it is not known how much ankle-foot orthosis moment is generated to regulate their motion. The aim of this study was to quantify the contribution of an articulated ankle-foot orthosis moment to regulate ankle and knee joint motion during gait in individuals post-stroke. Gait data were collected from 10 individuals post-stroke using a Bertec split-belt instrumented treadmill and a Vicon 3-dimensional motion analysis system. Each participant wore an articulated ankle-foot orthosis whose moment resisting plantarflexion was adjustable at four levels. Ankle-foot orthosis moment while walking was calculated under the four levels based on angle-moment relationship of the ankle-foot orthosis around the ankle joint measured by bench testing. The ankle-foot orthosis moment and the joint angular position (ankle and knee) relationship in a gait cycle was plotted to quantify the ankle-foot orthosis moment needed to regulate the joint motion. Ankle and knee joint motion were regulated according to the amount of ankle-foot orthosis moment during gait. The ankle-foot orthosis maintained the ankle angular position in dorsiflexion and knee angular position in flexion throughout a gait cycle when it generated moment from -0.029 (0.011) to -0.062 (0.019) Nm/kg (moment resisting plantarflexion was defined as negative). Quantifying the contribution of ankle-foot orthosis moment needed to regulate lower limb joints within a specific range of motion could provide valuable criteria to design an ankle-foot orthosis for individuals post-stroke. Copyright © 2017 Elsevier Ltd. All rights reserved.
Jeuken, Ralph M; Schotanus, Martijn G M; Kort, Nanne P; Deenik, Axel; Jong, Bob; Hendrickx, Roel P M
2016-07-01
Hallux valgus is one of the most common foot deformities. This long-term follow-up study compared the results of 2 widely used operative treatments for hallux valgus: the scarf and chevron osteotomy. Conventional weight bearing anteroposterior (AP) radiographs of the foot were made for evaluating the intermetatarsal angle and hallux valgus angle. For clinical evaluation, the American Orthopaedic Foot & Ankle Society (AOFAS) rating system for the hallux metatarsophalangeal-interphalangeal scale was used together with physical examination of the foot. These data were compared with the results from the original study. The Short Form 36 questionnaire, the Manchester-Oxford Foot Questionnaire (MOXFQ), and a general questionnaire including a visual analog scale (VAS) pain score were used for subjective evaluation. The primary outcome measures were the radiologic recurrence of hallux valgus and reoperation rate of the same toe. Secondary outcome measures were the results from the radiographs and subjective and clinical evaluation. The response rate was 76% at the follow-up of 14 years; in the chevron group, 37 feet were included compared with 36 feet in the scarf group. Twenty-eight feet in the chevron group and 27 in the scarf group developed recurrence of hallux valgus (P = .483). One patient in the scarf group had a reoperation of the same toe compared with none in the chevron group (P = .314). Current VAS pain scores and results from the SF-36, MOXFQ, and AOFAS did not significantly differ between groups. Both techniques showed similar results after 2 years of follow-up. At 14 years of follow-up, neither technique was superior in preventing recurrence. Level II, randomized controlled trial. © The Author(s) 2016.
3D gait assessment in young and elderly subjects using foot-worn inertial sensors.
Mariani, Benoit; Hoskovec, Constanze; Rochat, Stephane; Büla, Christophe; Penders, Julien; Aminian, Kamiar
2010-11-16
This study describes the validation of a new wearable system for assessment of 3D spatial parameters of gait. The new method is based on the detection of temporal parameters, coupled to optimized fusion and de-drifted integration of inertial signals. Composed of two wirelesses inertial modules attached on feet, the system provides stride length, stride velocity, foot clearance, and turning angle parameters at each gait cycle, based on the computation of 3D foot kinematics. Accuracy and precision of the proposed system were compared to an optical motion capture system as reference. Its repeatability across measurements (test-retest reliability) was also evaluated. Measurements were performed in 10 young (mean age 26.1±2.8 years) and 10 elderly volunteers (mean age 71.6±4.6 years) who were asked to perform U-shaped and 8-shaped walking trials, and then a 6-min walking test (6MWT). A total of 974 gait cycles were used to compare gait parameters with the reference system. Mean accuracy±precision was 1.5±6.8cm for stride length, 1.4±5.6cm/s for stride velocity, 1.9±2.0cm for foot clearance, and 1.6±6.1° for turning angle. Difference in gait performance was observed between young and elderly volunteers during the 6MWT particularly in foot clearance. The proposed method allows to analyze various aspects of gait, including turns, gait initiation and termination, or inter-cycle variability. The system is lightweight, easy to wear and use, and suitable for clinical application requiring objective evaluation of gait outside of the lab environment. Copyright © 2010 Elsevier Ltd. All rights reserved.
Proximal Opening Wedge Osteotomy Provides Satisfactory Midterm Results With a Low Complication Rate.
Oravakangas, Rami; Leppilahti, Juhana; Laine, Vesa; Niinimäki, Tuukka
2016-01-01
Hallux valgus is one of the most common foot deformities. Proximal opening wedge osteotomy is used for the treatment of moderate and severe hallux valgus with metatarsus primus varus. However, hypermobility of the first tarsometatarsal joint can compromise the results of the operation, and a paucity of midterm results are available regarding proximal open wedge osteotomy surgery. The aim of the present study was to assess the midterm results of proximal open wedge osteotomy in a consecutive series of patients with severe hallux valgus. Thirty-one consecutive adult patients (35 feet) with severe hallux valgus underwent proximal open wedge osteotomy. Twenty patients (35.5%) and 23 feet (34.3%) were available for the final follow-up examination. The mean follow-up duration was 5.8 (range 4.6 to 7.0) years. The radiologic measurements and American Orthopaedic Foot and Ankle Society hallux-metatarsophalangeal-interphalangeal scores were recorded pre- and postoperatively, and subjective questionnaires were completed and foot scan analyses performed at the end of the follow-up period. The mean hallux valgus angle decreased from 38° to 23°, and the mean intermetatarsal angle correction decreased from 17° to 10°. The mean improvement in the American Orthopaedic Foot and Ankle Society hallux metatarsophalangeal-interphalangeal score increased from 52 to 84. Two feet (5.7%) required repeat surgery because of recurrent hallux valgus. No nonunions were identified. Proximal open wedge osteotomy provided satisfactory midterm results in the treatment of severe hallux valgus, with a low complication rate. The potential instability of the first tarsometatarsal joint does not seem to jeopardize the midterm results of the operation. Copyright © 2016 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.
Biomechanical Comparison of 3 Ankle Braces With and Without Free Rotation in the Sagittal Plane
Alfuth, Martin; Klein, Dieter; Koch, Raphael; Rosenbaum, Dieter
2014-01-01
Context: Various designs of braces including hinged and nonhinged models are used to provide external support of the ankle. Hinged ankle braces supposedly allow almost free dorsiflexion and plantar flexion of the foot in the sagittal plane. It is unclear, however, whether this additional degree of freedom affects the stabilizing effect of the brace in the other planes of motion. Objective: To investigate the dynamic and passive stabilizing effects of 3 ankle braces, 2 hinged models that provide free plantar flexion–dorsiflexion in the sagittal plane and 1 ankle brace without a hinge. Design: Crossover study. Setting: University Movement Analysis Laboratory. Patients or Other Participants: Seventeen healthy volunteers (5 women, 12 men; age = 25.4 ± 4.8 years; height = 180.3 ± 6.5 cm; body mass = 75.5 ± 10.4 kg). Intervention(s): We dynamically induced foot inversion on a tilting platform and passively induced foot movements in 6 directions via a custom-built apparatus in 3 brace conditions and a control condition (no brace). Main Outcome Measure(s): Maximum inversion was determined dynamically using an in-shoe electrogoniometer. Passively induced maximal joint angles were measured using a torque and angle sensor. We analyzed differences among the 4 ankle-brace conditions (3 braces, 1 control) for each of the dependent variables with Friedman and post hoc tests (P < .05). Results: Each ankle brace restricted dynamic foot-inversion movements on the tilting platform as compared with the control condition, whereas only the 2 hinged ankle braces differed from each other, with greater movement restriction caused by the Ankle X model. Passive foot inversion was reduced with all ankle braces. Passive plantar flexion was greater in the hinged models as compared with the nonhinged brace. Conclusions: All ankle braces showed stabilizing effects against dynamic and passive foot inversion. Differences between the hinged braces and the nonhinged brace did not appear to be clinically relevant. PMID:25098661
Bunion correction using proximal chevron osteotomy: a single-incision technique.
Sammarco, G J; Russo-Alesi, F G
1998-07-01
Proximal chevron first metatarsal osteotomy with lateral capsulotomy, adductor tenotomy, and binding of the first and second metatarsals was reviewed in 88 consecutive cases. Seventy-two cases in 55 patients are reported, with an average clinical follow-up of 41 months. The hallux valgus angle improved an average of 15 degrees , from 32.0 degrees preoperatively to an average of 17.0 degrees postoperatively. The intermetatarsal I-II angle improved an average of 5.5 degrees, from 15.3 degrees preoperatively to 9.0 degrees postoperatively. The lateral plantar first metatarsal angle did not change. First metatarsal length was decreased by 2.0 mm. Union occurred at an average of 2 months. Sesamoid position improved 49%, from a preoperative average subluxation of 80% to a postoperative average subluxation of 29%. Subjective foot score profiles improved from a preoperative average of 70.1/100 to a postoperative average of 94.4/100 with respect to pain, deformity, motion, disability, and cosmesis. There were 10 patients with complications, including three patients with delayed unions, two with second metatarsal stress fractures, one with hallux varus, two with hallux limitus, one with progressive arthritis, one with cellulitis, and one with hallux elevatus. Eighty-four percent of the patients stated that they would undergo the procedure again without reservation, 9% would proceed with reservation, and 7% would not proceed with surgery again if offered. This technique provides reliable successful long-term results for the treatment of moderate and severe symptomatic bunion, hallux valgus, and metatarsus primus varus.
Zhang, Yi-Jun; Xu, Jian; Wang, Yue; Lin, Xiang-Jin; Ma, Xin
2015-02-01
The aim of this study was to explore the correlation between the kinematics of the hindfoot joint and the medial arch angle change in stage II posterior tibial tendon dysfunction flatfoot three-dimensionally under loading. Computed tomography (CT) scans of 12 healthy feet and 12 feet with stage II posterior tibial tendon dysfunction flatfoot were taken both in non- and full-body-weight-bearing condition. The CT images of the hindfoot bones were reconstructed into three-dimensional models with Mimics and Geomagic reverse engineering software. The three-dimensional changes of the hindfoot joint were calculated to determine their correlation to the medial longitudinal arch angle. The medial arch angle change was larger in stage II posterior tibial tendon dysfunction flatfoot compared to that in healthy foot under loading. The rotation and translation of the talocalcaneal joint, the talonavicular joint and the calcanocuboid joint had little influence on the change of the medial arch angle in healthy foot. However, the eversion of the talocalcaneal joint, the proximal translation of the calcaneus relative to the talus and the dorsiflexion of talonavicular joint could increase the medial arch angle in stage II posterior tibial tendon dysfunction flatfoot under loading. Joint instability occurred in patients with stage II posterior tibial tendon dysfunction flatfoot under loading. Limitation of over movement of the talocalcaneal joint and the talonavicular joint may help correct the medial longitudinal arch in stage II posterior tibial tendon dysfunction flatfoot. Copyright © 2014 Elsevier Ltd. All rights reserved.
Nikamp, Corien D M; van der Palen, Job; Hermens, Hermie J; Rietman, Johan S; Buurke, Jaap H
2018-06-01
Compensatory pelvis, hip- and knee movements are reported after stroke to overcome insufficient foot-clearance. Ankle-foot orthoses (AFOs) are often used to improve foot-clearance, but the optimal timing of AFO-provision post-stroke is unknown. Early AFO-provision to prevent foot-drop might decrease the development of compensatory movements, but it is unknown whether timing of AFO-provision affects post-stroke kinematics. 1) To compare the effect of AFO-provision at two different points in time (early versus delayed) on frontal pelvis and hip, and sagittal hip and knee kinematics in patients with sub-acute stroke. Effects were assessed after 26 weeks; 2) To study whether possible changes in kinematics or walking speed during the 26-weeks follow-up period differed between both groups. An explorative randomized controlled trial was performed, including unilateral hemiparetic patients maximal six weeks post-stroke with indication for AFO-use. Subjects were randomly assigned to AFO-provision early (at inclusion) or delayed (eight weeks later). 3D gait-analysis with and without AFO was performed in randomized order. Measurements were performed in study-week 1, 9, 17 and 26. Twenty-six subjects (15 early, 11 delayed) were analyzed. After 26 weeks, no differences in kinematics were found between both groups for any of the joint angles, both for the without and with AFO-condition. Changes in kinematics during the 26-weeks follow-up period did not differ between both groups for any of the joint angles during walking without AFO. Significant differences in changes in walking speed during the 26-weeks follow-up were found (p = 0.034), corresponding to the first eight weeks after AFO-provision. Results indicate that early or delayed AFO-use post-stroke does not influence pelvis, hip and knee movements after 26 weeks, despite that AFO-use properly corrected drop-foot. AFOs should be provided to improve drop-foot post-stroke, but not with the intention to influence development of compensatory patterns around pelvis and hip. Copyright © 2018 Elsevier B.V. All rights reserved.
2012-05-11
Stennis Space Center firefighter Rodney Boone rappels a tower structure during an onsite training exercise May 11, 2012. The training focused on high-angle rope rescues, which could be needed on the new 300-foot-tall A-3 Test Stand at Stennis.
Anticipatory postural adjustments for altering direction during walking.
Xu, Dali; Carlton, Les G; Rosengren, Karl S
2004-09-01
The authors examined how individuals adapt their gait and regulate their body configuration before altering direction during walking. Eight young adults were asked to change direction during walking with different turning angles (0 degree, 45 degree, 90 degree), pivot foot (left, right), and walking speeds (normal and fast). The authors used video and force platform systems to determine participants' whole-body center of mass and the center of pressure during the step before they changed direction. The results showed that anticipatory postural adjustments occurred during the prior step and occurred earlier for the fast walking speed. Anticipatory postural adjustments were affected by all 3 variables (turn angle, pivot foot, and speed). Participants leaned backward and sideward on the prior step in anticipation of the turn. Those findings indicate that the motor system uses central control mechanisms to predict the required anticipatory adjustments and organizes the body configuration on the basis of the movement goal.
NASA Technical Reports Server (NTRS)
Dziubala, T. J.; Marroquin, J.; Cleary, J. W.; Mellenthin, J. A.
1973-01-01
An experimental investigation was performed in the Ames Research Center 3.5-Foot Hypersonic Wind Tunnel to obtain detailed effects which interactions between the RCS jet flow field and the local orbiter flow field have on orbiter hypersonic stability and control characteristics. Six-component force data were obtained through an angle-of-attack range of 15 to 35 deg with 0 deg angle of sideslip. The test was conducted with yaw, pitch and roll jet simulation at a free-stream Mach number of 10.3. These data simulate two SSV reentry flight conditions at Mach numbers of 28.3 and 10.3. Fuselage base pressures and pressures on the nonmetric RCS pods were obtained in addition to the basic force measurements. Model 42-0 was used for these tests.
NASA Technical Reports Server (NTRS)
Petrozzi, M. T.; Milam, M. D.
1975-01-01
Experimental aerodynamic investigations were conducted in NASA/Langley 8-Foot transonic pressure tunnel on a sting mounted 0.010-scale outer mold line model of 104A/B configuration of the Rockwell International space shuttle vehicle. Component aerodynamic force and moment data and base and balance cavity pressures were recorded over an angle of attack range of -10 deg to +10 deg at Mach numbers of 0.6, 0.8, 0.9, 0.98, 1.13, and 1.2. Selected configurations were tested at sideslip angles from -10 deg to +10 deg. For all configurations involving the orbit, wing bending and torsion were measured on the right wing. Inboard elevon setting of 0 deg, +4 deg and +8 deg and outboard settings of 0 deg, +4 deg and +8 deg were tested.
NASA Technical Reports Server (NTRS)
Capone, F. J.
1981-01-01
An investigation was conducted in the Langley 16 Foot Transonic Tunnel to determine the aeropropulsive characteristics of a single expansion ramp nozzle (SERN) and a two dimensional convergent divergent nozzle (2-D C-D) installed with both an aft swept and a forward swept wing. The SERN was tested in both an upright and an inverted position. The effects of thrust vectoring at nozzle vector angles from -5 deg to 20 deg were studied. This investigation was conducted at Mach numbers from 0.40 to 1.20 and angles of attack from -2.0 deg to 16 deg. Nozzle pressure ratio was varied from 1.0 (jet off) to about 9.0. Reynolds number based on the wing mean geometric chord varied from about 3 million to 4.8 million, depending upon free stream number.
NASA Technical Reports Server (NTRS)
Kassner, D. L.; Wettlaufer, B.
1977-01-01
A typical missile model with nose-mounted canards and cruciform tail surfaces was tested in the Ames 6- by 6-Foot Wind Tunnel to determine the contributions of the component aerodynamic surfaces to the static aerodynamic characteristics at Mach numbers of 0.8, 1.3, and 1.75 and Reynolds number of 625,000 based on body diameter. Data were obtained at angles of attack ranging from 0 deg to 24 deg for various stages of model build-up (i.e., with and without canard and/or tail surfaces). In addition, two different sets of canards and tail surfaces were investigated. For the canard and tail arrangements investigated, the model was trimmable at angles of attack up to about 7 deg with canard deflections of about 10 deg. Also, the tail arrangements studied provided ample pitch stability.
Almonroeder, Thomas G; Benson, Lauren C; O'Connor, Kristian M
2016-09-01
Study Design Controlled laboratory study, cross-sectional. Background Orthotic prescription is often based on the premise that the mechanical effects will be more prominent in individuals with greater calcaneal eversion. Objective To compare the effects of a prefabricated foot orthosis on lower extremity kinematics and kinetics between recreational athletes with high and low calcaneal eversion during running. Methods Thirty-one recreational athletes were included in this study. Three-dimensional kinematic and kinetic data were collected while running with and without a foot orthosis. Participants were grouped based on the degree of calcaneal eversion during the running trials relative to a standing trial (dynamic foot motion). The effects of the orthosis on the frontal and transverse plane angles and moments of the hip and knee were compared between the 10 participants with the greatest and least amount of dynamic foot motion. Results There were no significant interactions (group by orthotic condition) for any of the kinematic or kinetic variables of interest. Conclusion The effects of an orthosis on the mechanics of the hip and knee do not appear to be dependent on an individual's dynamic foot motion. J Orthop Sports Phys Ther 2016;46(9):749-755. Epub 5 Aug 2016. doi:10.2519/jospt.2016.6253.
Mumby, C; Bouts, T; Sambrook, L; Danika, S; Rees, E; Parry, A; Rendle, M; Masters, N; Weller, R
2013-10-05
Foot problems are extremely common in elephants and radiography is the only imaging method available but the radiographic anatomy has not been described in detail. The aims of this study were to develop a radiographic protocol for elephant feet using digital radiography, and to describe the normal radiographic anatomy of the Asian elephant front and hind foot. A total of fifteen cadaver foot specimens from captive Asian elephants were radiographed using a range of projections and exposures to determine the best radiographic technique. This was subsequently tested in live elephants in a free-contact setting. The normal radiographic anatomy of the Asian elephant front and hind foot was described with the use of three-dimensional models based on CT reconstructions. The projection angles that were found to be most useful were 65-70° for the front limb and 55-60° in the hind limb. The beam was centred 10-15 cm proximal to the cuticle in the front and 10-15 cm dorsal to the plantar edge of the sole in the hind foot depending on the size of the foot. The protocol developed can be used for larger-scale diagnostic investigations of captive elephant foot disorders, while the normal radiographic anatomy described can improve the diagnostic reliability of elephant feet radiography.
NASA Technical Reports Server (NTRS)
Applin, Zachary T.; Gentry, Garl L., Jr.; Takallu, M. A.
1995-01-01
A wind tunnel investigation was conducted on a generic, high-wing transport model in the Langley 14- by 22-Foot Subsonic Tunnel. This report contains pressure data that document effects of various model configurations and free-stream conditions on wing pressure distributions. The untwisted wing incorporated a full-span, leading-edge Krueger flap and a part-span, double-slotted trailing-edge flap system. The trailing-edge flap was tested at four different deflection angles (20 deg, 30 deg, 40 deg, and 60 deg). Four wing configurations were tested: cruise, flaps only, Krueger flap only, and high lift (Krueger flap and flaps deployed). Tests were conducted at free-stream dynamic pressures of 20 psf to 60 psf with corresponding chord Reynolds numbers of 1.22 x 10(exp 6) to 2.11 x 10(exp 6) and Mach numbers of 0.12 to 0.20. The angles of attack presented range from 0 deg to 20 deg and were determined by wing configuration. The angle of sideslip ranged from minus 20 deg to 20 deg. In general, pressure distributions were relatively insensitive to free-stream speed with exceptions primarily at high angles of attack or high flap deflections. Increasing trailing-edge Krueger flap significantly reduced peak suction pressures and steep gradients on the wing at high angles of attack. Installation of the empennage had no effect on wing pressure distributions. Unpowered engine nacelles reduced suction pressures on the wing and the flaps.
NASA Technical Reports Server (NTRS)
Sinclair, Archibald R; Mace, William D
1956-01-01
A limited calibration of a combined pitot-static tube and vane-type flow-angularity indicator has been made in the Langley 4- by 4-foot supersonic pressure tunnel at Mach numbers of 1.61 and 2.01. The results indicated that the angle-of-yaw indications were affected by unsymmetric shock effects at low angles of attack.
Characterization of multidrug-resistant diabetic foot ulcer enterococci.
Semedo-Lemsaddek, Teresa; Mottola, Carla; Alves-Barroco, Cynthia; Cavaco-Silva, Patrícia; Tavares, Luís; Oliveira, Manuela
2016-02-01
Diabetes mellitus is a highly prevalent chronic progressive disease with complications that include diabetic-foot ulcers. Enterococci isolated from diabetic-foot infections were identified, evaluated by macro-restriction analysis, and screened for virulence traits and antimicrobial resistance. All isolates were considered multidrug-resistant, cytolysin and gelatinase producers, and the majority also demonstrated the ability to produce biofilms. These results indicate the importance of enterococci in diabetic-foot infection development and persistence, especially regarding their biofilm-forming ability and resistance to clinically relevant antibiotics. Copyright © 2015 Elsevier España, S.L.U. y Sociedad Española de Enfermedades Infecciosas y Microbiología Clínica. All rights reserved.
Low speed aerodynamic characteristics of the GD/C B-18E3 booster
NASA Technical Reports Server (NTRS)
Carter, W. V.; Gallaher, W. H.
1972-01-01
A 0.02 scale model of the B-18E3 space shuttle booster was tested in a low speed wind tunnel to evaluate the low speed aerodynamic charactersitics. The basic configuration, including build-up, was tested at a Mach number of 0.201 and Reynolds number per foot of 1.39 million. The normal angle-of-attack range was -4 to +24 degrees in 2 degree increments, at sideslip angles of 0 and 5 degrees. Some lateral data were obtained at the sideslip angle range of -6 to 10 degrees at angles-of attack of 0, 10, and 15 degrees. Data were obtained for canard, split elevon, and split rudder deflections.
NASA Technical Reports Server (NTRS)
Moul, T. M.
1979-01-01
A preliminary wind tunnel investigation was undertaken to determine the flow correction for a vane angle of attack sensor over an angle of attack range from -10 deg to 110 deg. The sensor was mounted ahead of the wing on a 1/5 scale model of a general aviation airplane. It was shown that the flow correction was substantial, reaching about 15 deg at an angle of attack of 90 deg. The flow correction was found to increase as the sensor was moved closer to the wing or closer to the fuselage. The experimentally determined slope of the flow correction versus the measured angle of attack below the stall angle of attack agreed closely with the slope of flight data from a similar full scale airplane.
NASA Technical Reports Server (NTRS)
Aiken, T. N.; Falarski, M. D.; Koenin, D. G.
1979-01-01
The aerodynamic characteristics of the augmentor wing concept with hypermixing primary nozzles were investigated. A large-scale semispan model in the Ames 40- by 80-Foot Wind Tunnel and Static Test Facility was used. The trailing edge, augmentor flap system occupied 65% of the span and consisted of two fixed pivot flaps. The nozzle system consisted of hypermixing, lobe primary nozzles, and BLC slot nozzles at the forward inlet, both sides and ends of the throat, and at the aft flap. The entire wing leading edge was fitted with a 10% chord slat and a blowing slot. Outboard of the flap was a blown aileron. The model was tested statically and at forward speed. Primary parameters and their ranges included angle of attack from -12 to 32 degrees, flap angles of 20, 30, 45, 60 and 70 degrees, and deflection and diffuser area ratios from 1.16 to 2.22. Thrust coefficients ranged from 0 to 2.73, while nozzle pressure ratios varied from 1.0 to 2.34. Reynolds number per foot varied from 0 to 1.4 million. Analysis of the data indicated a maximum static, gross augmentation of 1.53 at a flap angle of 45 degrees. Analysis also indicated that the configuration was an efficient powered lift device and that the net thrust was comparable with augmentor wings of similar static performance. Performance at forward speed was best at a diffuser area ratio of 1.37.
Karabicak, Gul Oznur; Bek, Nilgun; Tiftikci, Ugur
2015-10-01
The main aim of this study was to measure short-term effects of kinesiotaping on pain and joint alignment in the conservative treatment of hallux valgus. Twenty-one female patients diagnosed with a total of 34 feet with hallux valgus (13 bilateral, 6 right, and 2 left) participated in this study. Kinesiotaping was implemented after the first assessment and renewed in days 3, 7, and 10. The main outcome measures were pain, as assessed using visual analog scale, and hallux adduction angle, as measured by goniometry. Secondary outcome measure was patients' functional status, as measured by Foot Function Index and the hallux valgus scale of the American Orthopaedic Foot and Ankle Society (AOFAS). The radiographic results were also measured before and after 1 month of treatment. The Wilcoxon test was used to compare the differences between initial and final scores of AOFAS, as well as FFI scales and hallux valgus angle assessment scores. There was a significant reduction in goniometric measurement of hallux valgus angle (P = .001). There was a significant reduction in pain intensity (P = .001) and AOFAS and Foot Function Index scores at the end of the treatment (P = .001 and P = .001, respectively). There was a significant difference between radiographic results in 1-month control (P = .009). For this group of female patients, pain and joint alignment were improved after a 10-day kinesiotape implementation in patients with hallux valgus. The findings showed short-term decreased pain and disability in hallux valgus deformity. Copyright © 2015 National University of Health Sciences. Published by Elsevier Inc. All rights reserved.
Prachgosin, Tulaya; Leelasamran, Wipawan; Smithmaitrie, Pruittikorn; Chatpun, Surapong
2017-12-01
Total-contact orthosis (TCO) is one kind of foot orthosis (FO) that is used to adjust biomechanics in flexible flatfoot. To determine the effects of a TCO on the MLA moment, MLA deformation angle and lower limb biomechanics. Cross-sectional study. Seven-flatfoot and thirteen-normal foot subjects were recruited by footprint and radiographs. The biomechanics of subjects with normal foot (NF), flatfoot with shoe only (FWOT) and flatfoot with TCO (FWT) were collected in a 3D motion analysis laboratory and force plates. The MLA and lower limb biomechanics in each condition during specific sub-phases of stance were analyzed. The NF had larger MLA eversion moment after shod walking ( p = 0.001). The FWT condition compared with the FWOT condition had a significantly larger peak MLA upward moment ( p = 0.035) during pre-swing, larger peak knee external rotation angle ( p = 0.040) during mid stance, smaller peak knee extension moment during terminal stance ( p = 0.035) and a larger ground reaction force in the anterior-posterior direction during early stance ( p < 0.05). Our study found positive effects from the customized TCOs which included an increased TCO angle that led to a decreased peak MLA moment in the frontal plane in flexible flatfoot subjects during walking. Clinical relevance Lower limb biomechanics is different from normal in subjects with flexible flatfoot. The design of a TCO affects MLA, ankle and knee biomechanics and may be used to clinically correct biomechanical changes in flexible flatfoot.
NASA Technical Reports Server (NTRS)
Bare, E. Ann; Capone, Francis J.
1989-01-01
An investigation was conducted in the Static Test Facility of the Langley 16-Foot Transonic Tunnel to determine the effects of five geometric design parameters on the internal performance of convergent single expansion ramp nozzles. The effects of ramp chordal angle, initial ramp angle, flap angle, flap length, and ramp length were determined. All nozzles tested has a nominally constant throat area and aspect ratio. Static pressure distributions along the centerlines of the ramp and flap were also obtained for each configuration. Nozzle pressure ratio was varied up to 10.0 for all configurations.
Static internal performance of a two-dimensional convergent-divergent nozzle with thrust vectoring
NASA Technical Reports Server (NTRS)
Bare, E. Ann; Reubush, David E.
1987-01-01
A parametric investigation of the static internal performance of multifunction two-dimensional convergent-divergent nozzles has been made in the static test facility of the Langley 16-Foot Transonic Tunnel. All nozzles had a constant throat area and aspect ratio. The effects of upper and lower flap angles, divergent flap length, throat approach angle, sidewall containment, and throat geometry were determined. All nozzles were tested at a thrust vector angle that varied from 5.60 tp 23.00 deg. The nozzle pressure ratio was varied up to 10 for all configurations.
NASA Technical Reports Server (NTRS)
Henderson, W. P.; Huffman, J. K.
1974-01-01
An investigation has been conducted to determine the effects of configuration variables on the lateral-directional stability characteristics of a wing-fuselage configuration. The variables under study included variations in the location of a single center-line vertical tail and twin vertical tails, wing height, fuselage strakes, and horizontal tails. The study was conducted in the Langley high-speed 7-by 10-foot tunnel at a Mach number of 0.30, at angles of attack up to 44 deg and at sideslip angles of 0 deg and plus or minus 5 deg.
Laser velocimeter measurements of dynamic stall. [conducted in the Ames two foot wind tunnel
NASA Technical Reports Server (NTRS)
Owen, F. K.
1984-01-01
Laser velocimeter measurements were made during the study of a two-dimensional NACA 0012 airfoil undergoing conditions of dynamic stall. The measurements, which were obtained in the Ames 2 foot wind tunnel at reduced frequencies of 0.12 and 1.2, show significant flow field hysteresis around the static stall angle. Comparisons were also made with dual-plate interferograms and good agreement was found for the attached flow cases. For separated flow, characteristic vortex shedding caused poor agreement and significantly increased the measured Reynolds shear stresses.
Foot Structure in Boys with Down Syndrome
Nowak, Krzysztof; Omorczyk, Jarosław; Ambroży, Tadeusz; Nosiadek, Leszek
2017-01-01
Introduction and Aim Down syndrome (DS) is associated with numerous developmental abnormalities, some of which cause dysfunctions of the posture and the locomotor system. The analysis of selected features of the foot structure in boys with DS versus their peers without developmental disorders is done. Materials and Methods The podoscopic examination was performed on 30 boys with DS aged 14-15 years. A control group consisted of 30 age- and gender-matched peers without DS. Results The feet of boys with DS are flatter compared to their healthy peers. The hallux valgus angle is not the most important feature differentiating the shape of the foot in the boys with DS and their healthy peers. In terms of the V toe setting, healthy boys had poorer results. Conclusions Specialized therapeutic treatment in individuals with DS should involve exercises to increase the muscle strength around the foot joints, enhancing the stabilization in the joints and proprioception. Introducing orthotics and proper footwear is also important. It is also necessary to monitor the state of the foot in order to modify undertaken therapies. PMID:28904967
Feigenbaum, Luis A; Roach, Kathryn E; Kaplan, Lee D; Lesniak, Bryson; Cunningham, Sean
2013-11-01
Case-control. The specific aim of this study was to examine the association between abnormal foot arch postures and a history of shoulder or elbow surgery in baseball pitchers. Pitching a baseball generates forces throughout the musculoskeletal structures of the upper and lower limbs. Structures such as the longitudinal arch of the foot are adaptable to stresses over time. Repeated pitching-related stresses may contribute to acquiring abnormal foot arch postures. Inversely, congenitally abnormal foot arch posture may lead to altered stresses of the upper limb during pitching. A convenience sample of 77 pitchers was recruited from a Division I university team and a professional baseball franchise. Subjects who had a history of shoulder or elbow surgery to the pitching arm were classified as cases. Subjects who met the criteria for classification of pes planus or pes cavus based on longitudinal arch angle were classified as having abnormal foot arch posture. Odds ratios were calculated to examine the association between abnormal foot arch posture and pitching-arm injury requiring surgery. Twenty-three subjects were classified as cases. The odds of being a case were 3.4 (95% confidence interval: 1.2, 9.6; P = .02) times greater for subjects with abnormal foot arch posture and 2.9 (95% confidence interval: 1.0, 8.1; P = .04) times greater for subjects with abnormal foot posture on the lunge leg. Abnormal foot arch posture and a surgical history in the pitching shoulder or elbow may be associated. Because the foot and its arches are adaptable and change over time, the pathomechanics of this association should be further explored.
Effect of shoe insert construction on foot and leg movement.
Nigg, B M; Khan, A; Fisher, V; Stefanyshyn, D
1998-04-01
The purpose of this study was to quantify changes in foot eversion and tibial rotation during running resulting from systematic changes of material composition of five shoe inserts of the same shape. Tests were performed with 12 subjects. The inserts had a bilayer design using two different materials at the top and bottom of the insert. The functional kinematic variables examined in this study were the foot-leg in-eversion angle, beta, and the leg-foot tibial rotation, rho. Additionally, the subject characteristics of arch height, relative arch deformation, and active range of motion were quantified. The statistical analysis used was a two way repeated measures MANOVA (within trials and inserts). The average group changes resulting from the studied inserts in total shoe eversion, total foot eversion, and total internal tibial rotation were typically smaller than 1 degree when compared with the no-insert condition and were statistically not significant. The measured ranges of total foot eversion for all subjects were smallest for the softest and about twice as large for the hardest insert construction. Thus, the soft insert construction was more restrictive, forcing all feet into a similar movement pattern, whereas the harder combinations allowed for more individual variation of foot and leg movement and did not force the foot into a preset movement pattern. The individual results showed substantial differences between subjects and a trend: Subjects who generally showed a reduction of tibial rotation with all tested inserts typically had a flexible foot. However, subjects who generally showed an increase of tibial rotation typically had a stiff foot. The results of this study suggest that subject specific factors such as static, dynamic, and neuro-physiological characteristics of foot and leg are important to match specific feet and shoe inserts optimally.
Gender differences of foot characteristics in older Japanese adults using a 3D foot scanner.
Saghazadeh, Mahshid; Kitano, Naruki; Okura, Tomohiro
2015-01-01
Knowledge of gender differences in foot shape assists shoe manufactures with designing appropriate shoes for men and women. Although gender differences in foot shapes are relatively known among young men and women, less is known about how the older men and women's feet differ in shape. A recent development in foot shape assessment is the use of 3D foot scanners. To our knowledge this technology has yet to be used to examine gender differences in foot shape of Japanese older adults. This cross-sectional study included 151 older men (74.5 ± 5.6 years) and 140 older women (73.9 ± 5.1 years) recruited in Kasama City, Japan. Foot variables were measured in sitting and standing positions using Dream GP Incorporated's 3D foot scanner, Footstep PRO (Osaka, Japan). Scores were analyzed as both raw and normalized to truncated foot length using independent samples t-test and analysis of covariance, respectively. In men, the measurement values for navicular height, first and fifth toe and instep heights, ball and heel width, ball girth, arch height index (just standing), arch rigidity index and instep girth were significantly greater than the women's, whereas the first toe angle, in both sitting and standing positions was significantly smaller. However, after normalizing, the differences in ball width, heel width, height of first and fifth toes in both sitting and standing and ball girth in sitting position were nonsignificant. According to Cohen's d, among all the foot variables, the following had large effect sizes in both sitting and standing positions: truncated foot length, instep, navicular height, foot length, ball girth, ball width, heel width and instep girth. This study provides evidence of anthropometric foot variations between older men and women. These differences need to be considered when manufacturing shoes for older adults.
Alemdaroğlu, İpek; Gür, Gozde; Bek, Nilgün; Yilmaz, Öznur T; Yakut, Yavuz; Uygur, Fatma; Karaduman, Ayşe
2014-02-01
Contractures of Achilles tendons and gastrocnemius muscle deteriorate the performance in daily living activities of patients with neuromuscular diseases. Ankle-foot orthoses help to prevent the progression of deformities and to obtain optimal position of the joints to support standing and walking. To investigate the relationship between orthotic usage and functional activities in pediatric patients with different neuromuscular diseases. Retrospective study. A total of 127 subjects' physical assessment forms were analyzed. Functional level, type of orthoses, falling frequencies, ankle joint range of motion, and timed performance tests were examined in two consecutive dates with an interval of 3 months. A total of 91 patients were using orthoses while 36 patients were not within assessment dates. A total of 64 of 91 (70.3%) patients were diagnosed with Duchenne muscular dystrophy. A total of 81 (89.0%) subjects were using plastic ankle-foot orthoses for positioning at nights and 10 (11%) were using different types of the orthoses (knee-ankle-foot orthoses, dynamic ankle-foot orthoses, and so on) for gait in the study group. Night ankle-foot orthoses were not found to be effective directly on functional performance in children with neuromuscular diseases, although they protect ankle from contractures and may help to correct gait and balance. This retrospective study shows that the positive effects of using an ankle-foot orthosis at night are not reflected in the functional performance of children with neuromuscular diseases. This may be due to the progressive deteriorating nature of the disease.
NASA Technical Reports Server (NTRS)
Avery, D. E.
1985-01-01
The heat transfer to simulated shuttle thermal protection system tiles was investigated experimentally by using a highly instrumented metallic thin wall tile arranged with other metal tiles in a staggered tile array. Cold wall heating rate data for laminar and turbulent flow were obtained in the Langley 8 foot high Temperature Tunnel at a nominal Mach number of 7, a nominal total temperature of 3300R, a free stream unit Reynolds number from 3.4 x 10 sup 5 to 2.2 10 sup 6 per foot, and a free stream dynamic pressure from 2.1 to 9.0 psia. Experimental data are presented to illustrate the effects of flow angularity and gap width on both local peak heating and overall heating loads. For the conditions of the present study, the results show that localized and total heating are sensitive to changes in flow angle only for the test conditions of turbulent boundary layer flow with high kinetic energy and that a flow angle from 30 deg to 50 deg will minimize the local heating.
NASA Technical Reports Server (NTRS)
Pinier, Jeremy T.; Erickson, Gary E.; Paulson, John W.; Tomek, William G.; Bennett, David W.; Blevins, John A.
2015-01-01
A 1.75% scale force and moment model of the Space Launch System was tested in the NASA Langley Research Center 14- by 22-Foot Subsonic Wind Tunnel to quantify the aerodynamic forces that will be experienced by the launch vehicle during its liftoff and transition to ascent flight. The test consisted of two parts: the first was dedicated to measuring forces and moments for the entire range of angles of attack (0deg to 90deg) and roll angles (0 deg. to 360 deg.). The second was designed to measure the aerodynamic effects of the liftoff tower on the launch vehicle for ground winds from all azimuthal directions (0 deg. to 360 deg.), and vehicle liftoff height ratios from 0 to 0.94. This wind tunnel model also included a set of 154 surface static pressure ports. Details on the experimental setup, and results from both parts of testing are presented, along with a description of how the wind tunnel data was analyzed and post-processed in order to develop an aerodynamic database. Finally, lessons learned from experiencing significant dynamics in the mid-range angles of attack due to steady asymmetric vortex shedding are presented.
NASA Technical Reports Server (NTRS)
Carter, Melissa B.; Shea, Patrick R.; Flamm, Jeffrey D.; Schuh, Michael; James, Kevin D.; Sexton, Matthew R.; Tompkins, Daniel M.; Beyar, Michael D.
2016-01-01
As part of the NASA Environmentally Responsible Aircraft project, an ultra high bypass ratio engine integration on a hybrid wing body demonstration was planned. The goal was to include engine and airframe integration concepts that reduced fuel consumption by at least 50% while still reducing noise 42 db cumulative on the ground. Since the engines would be mounted on the upper surface of the aft body of the aircraft, the inlets may be susceptible to vortex ingestion from the wing leading edge at high angles of attack and sideslip, and separated wing/body flow. Consequently, experimental and computational studies were conducted to collect flow surveys useful for characterizing engine operability. The wind tunnel tests were conducted at two NASA facilities, the 14- by 22-foot at NASA Langley and the 40- by 80-foot at NASA Ames Research Center. The test results included in this paper show that the distortion and pressure recovery levels were acceptable for engine operability. The CFD studies conducted to compare to experimental data showed excellent agreement for the angle of attacks examined, although failed to match the low speed experimental data at high sideslip angles.
Some biomechanical aspects of the foot and ankle in athletes with and without shin splints.
Viitasalo, J T; Kvist, M
1983-01-01
Thirteen adult male athletes (long-distance runners and orienteerers without foot problems) and 35 male athletes with shin splints were compared with respect to: 1) the position of the lower leg and the heel while standing, 2) the passive range of mobility in the subtalar joint, and 3) the angular displacement between the calcaneus and the midline of the lower leg (Achilles tendon angle) while running with bare feet on a treadmill. In standing, the two groups differed statistically significantly in the Achilles tendon angle, which values were greater in the shin splint group. With respect to passive mobility, the athletes with shin splints had significantly greater (P less than 0.05-0.01) angular displacement values in inversion, eversion, and in their sum than the control group. While running, the Achilles tendon angle of the shin splint group was significantly greater (P less than 0.01) at the heel strike. Further, the shin splints group had a significantly greater (P less than 0.01) angular displacement between the heel strike and the maximal everted position. The results suggest structural and functional differences in the feet and ankles between healthy athletes and those with shin splints.
Adaptive harvest management for the Svalbard population of pink-footed geese: briefing summary
Johnson, Fred A.
2013-01-01
The African-Eurasian Waterbird Agreement (AEWA; http://www.unep-aewa.org/) calls for means to manage populations which cause conflicts with certain human economic activities. The Svalbard population of the pink-footed goose has been selected as the first test case for such an international species management plan to be developed. This document describes progress to date on the development of an adaptive harvest management (AHM) strategy for maintaining pink-footed goose abundance near their target level by providing for sustainable harvasts in Norway and Denmark. This briefing supplements material provided in the Progress Summary distributed to the International Working Group on February 1, 2013. We emphasize that peer review is an essential aspect of the process of developing and implementing an AHM program for pink-footed geese, and we will continue to solicit reviews by the International Working Group and their staff, as well as scientists not engaged in this effort. We wish to make the Working Group aware the the following two manuscripts have been submitted recently to refereed journals and are available upon request from the senior authors: Jensen, G.H., J. Madsen, F.A. Johnson, and M. Tamstorf. Snow conditions as an estimator of the breeding output in high-Arctic pink-footed geese Anser brachyrhynchus. Polar Biology: In review. Johnson, F.A., G.H. Jensen, J. Madsen, and B.K. Williams. Uncertainity, robustness, and the value of information in managing an expanding Arctic goose population. Ecological Modeling: In review. In addition to these manuscripts, the Progress Summary (February 1, 2013), and this Briefing Summary (April 23, 2013) an annual report will be produced in August 2013 and every summer thereafter. Additional manuscripts for journal publication are also anticipated.
NASA Technical Reports Server (NTRS)
Huffman, J. K.; Fox, C. H., Jr.; Satterthwaite, R. E.
1977-01-01
An escape system extraction rocket proposed for use on the Rotor Systems Research Aircraft was tested at Mach numbers of 0.1 and 0.3 through an angle of attack range from -2 deg to 102 deg and an angle of sideslip range from 0 deg to 15 deg in the Langley 7- by 10-foot high speed tunnel. The data are presented without analysis.
Bunion removal - series (image)
... causes the joint to thicken and enlarge. This causes the bones of the big toe to angle in toward and over the ... pain-free (general anesthesia) and rarely requires a hospital ... the bones of the big toe into the foot. The deformed joint and ...
Parachute Questionnaire Project,
1945-03-17
i Ankle ---- ---- 8 Knee ---.--.-- 9 Spine 2 Neck Muscles -5 Arch of foot ---------- 2 Leg muscles 1 Pelvis 2 0 Sacroiliac Joint ---- I Femur...11 Angle .- 2 Leg -0------ 1 Cartilage of knee ---- 1 Chest ...- . 9 Symphysis Pubis 1 Sacrum .... - 5 Sacroiliac joint -------- 1 Groin ..... . 4
Mechanics of jazz shoes and their effect on pointing in child dancers.
Fong Yan, Alycia; Smith, Richard; Vanwanseele, Benedicte; Hiller, Claire
2012-07-01
There has been little scientific investigation of the impact of dance shoes on foot motion or dance injuries. The pointed (plantar-flexed) foot is a fundamental component of both the technical requirements and the traditional aesthetic of ballet and jazz dancing. The aims of this study were to quantify the externally observed angle of plantar flexion in various jazz shoes compared with barefoot and to compare the sagittal plane bending stiffness of the various jazz shoes. Sixteen female recreational child dancers were recruited for 3D motion analysis of active plantar flexion. The jazz shoes tested were a split-sole jazz shoe, full-sole jazz shoe, and jazz sneaker. A shoe dynamometer measured the stiffness of the jazz shoes. The shoes had a significant effect on ankle plantar flexion. All jazz shoes significantly restricted the midfoot plantar flexion angle compared with the barefoot condition. The split-sole jazz shoe demonstrated the least restriction, whereas the full-sole jazz shoe the most midfoot restriction. A small restriction in metartarsophalangeal plantar flexion and a greater restriction at the midfoot joint were demonstrated when wearing stiff jazz shoes. These restrictions will decrease the aesthetic of the pointed foot, may encourage incorrect muscle activation, and have an impact on dance performance.
Determination of Ankle and Metatarsophalangeal Stiffness During Walking and Jogging.
Mager, Fabian; Richards, Jim; Hennies, Malika; Dötzel, Eugen; Chohan, Ambreen; Mbuli, Alex; Capanni, Felix
2018-05-29
Forefoot stiffness has been shown to influence joint biomechanics. However, little or no data exists on metatarsophalangeal stiffness. Twenty-four healthy rearfoot strike runners were recruited from a staff and student population at the University of Central Lancashire. Five repetitions of shod, self-selected speed level walking and jogging were performed. Kinetic and kinematic data were collected using retro-reflective markers placed on the lower limb and foot, to create a three-segment foot model using the Calibrated Anatomical System Technique. Ankle and metatarsophalangeal moments and angles were calculated. Stiffness values were calculated using a linear best fit line of moment versus of angle plots. Paired t-tests were used to compare values between walking and jogging conditions. Significant differences were seen in ankle range of motion (ROM), but not in metatarsophalangeal ROM. Maximum moments were significantly greater in the ankle during jogging, but these were not significantly different at the metatarsophalangeal joint. Average ankle joint stiffness exhibited significantly lower stiffness when walking compared to jogging. However, the metatarsophalangeal joint exhibited significantly greater stiffness when walking compared to jogging. A greater understanding of forefoot stiffness may inform the development of footwear, prosthetic feet and orthotic devices, such as ankle-foot orthoses for walking and sporting activities.
76 FR 2722 - Petitions for Modification of Existing Mandatory Safety Standards
Federal Register 2010, 2011, 2012, 2013, 2014
2011-01-14
.... Sufficient supplies of ventilation materials will be available near the working face; (7) The methane monitor... points; (9) When mining is in progress, tests for methane will be made with a handheld methane detector... until the well is mined through; (11) If methane is detected 1-foot from the rib and 1-foot above the...
Wind tunnel tests on a one-foot diameter SR-7L propfan model
NASA Technical Reports Server (NTRS)
Aljabri, Abdullah S.
1987-01-01
Wind tunnel tests have been conducted on a one-foot diameter model of the SR-7L propfan in the Langley 16-Foot and 4 x 7 Meter Wind Tunnels as part of the Propfan Test Assessment (PTA) Program. The model propfan was sized to be used on a 1/9-scale model of the PTA testbed aircraft. The model propeller was tested in isolation and wing-mounted on the aircraft configuration at various Mach numbers and blade pitch angles. Agreement between data obtained from these tests and data from Hamilton Standard validate that the 1/9-scale propeller accurately simulates the aerodynamics of the SR-7L propfan. Predictions from an analytical computer program are presented and show good agreement with the experimental data.
Ho, Sean Wei Loong; Thevendran, Gowreeson
2016-06-01
Foot and ankle abnormalities are common in Singapore because of the compulsory conscription, the slipper-wearing culture, and the promotion of healthy living through exercise. The rapidly aging population, lack of elite sportsmen, and social and cultural norms pose unique challenges to foot and ankle surgery. Orthopedic surgery in Singapore has progressed because of the good infrastructure and modern practices executed by fellowship-trained surgeons. Evolving local practices are polarized by practice trends emulated from North America and Europe. The small community of foot and ankle surgeons currently practicing in Singapore allows for easier communication, corroborative educational events, and research initiatives. Copyright © 2016 Elsevier Inc. All rights reserved.
Progress Update: Stack Project Complete
Cody, Tom
2017-12-12
Progress update from the Savannah River Site. The 75 foot 293 F Stack, built for plutonium production, was cut down to size in order to prevent injury or release of toxic material if the structure were to collapse due to harsh weather.
Mei, Qichang; Fernandez, Justin; Fu, Weijie; Feng, Neng; Gu, Yaodong
2015-08-01
Running is one of the most accessible physical activities and running with and without footwear has attracted extensive attention in the past several years. In this study 18 habitually male unshod runners and 20 habitually male shod runners (all with dominant right feet) participated in a running test. A Vicon motion analysis system was used to capture the kinematics of each participant's lower limb. The in-shoe plantar pressure measurement system was employed to measure the pressure and force exerted on the pressure sensors of the insole. The function of a separate hallux in unshod runners is analyzed through the comparison of plantar pressure parameters. Owing to the different strike patterns in shod and unshod runners, peak dorsiflexion and plantarflexion angle were significantly different. Habitually shod runners exhibited a decreased foot strike angle (FSA) under unshod conditions; and the vertical average loading rate (VALR) of shod runners under unshod conditions was larger than that under shod conditions. This suggests that the foot strike pattern is more important than the shod or unshod running style and runners need to acquire the technique. It can be concluded that for habitually unshod runners the separate hallux takes part of the foot loading and reduces loading to the forefoot under shod conditions. The remaining toes of rearfoot strike (RFS) runners function similarly under unshod conditions. These morphological features of shod and unshod runners should be considered in footwear design to improve sport performance and reduce injury. Copyright © 2015 Elsevier B.V. All rights reserved.
Comparison of three-dimensional multi-segmental foot models used in clinical gait laboratories.
Nicholson, Kristen; Church, Chris; Takata, Colton; Niiler, Tim; Chen, Brian Po-Jung; Lennon, Nancy; Sees, Julie P; Henley, John; Miller, Freeman
2018-05-16
Many skin-mounted three-dimensional multi-segmented foot models are currently in use for gait analysis. Evidence regarding the repeatability of models, including between trial and between assessors, is mixed, and there are no between model comparisons of kinematic results. This study explores differences in kinematics and repeatability between five three-dimensional multi-segmented foot models. The five models include duPont, Heidelberg, Oxford Child, Leardini, and Utah. Hind foot, forefoot, and hallux angles were calculated with each model for ten individuals. Two physical therapists applied markers three times to each individual to assess within and between therapist variability. Standard deviations were used to evaluate marker placement variability. Locally weighted regression smoothing with alpha-adjusted serial T tests analysis was used to assess kinematic similarities. All five models had similar variability, however, the Leardini model showed high standard deviations in plantarflexion/dorsiflexion angles. P-value curves for the gait cycle were used to assess kinematic similarities. The duPont and Oxford models had the most similar kinematics. All models demonstrated similar marker placement variability. Lower variability was noted in the sagittal and coronal planes compared to rotation in the transverse plane, suggesting a higher minimal detectable change when clinically considering rotation and a need for additional research. Between the five models, the duPont and Oxford shared the most kinematic similarities. While patterns of movement were very similar between all models, offsets were often present and need to be considered when evaluating published data. Copyright © 2018 Elsevier B.V. All rights reserved.
The reliability of the Adelaide in-shoe foot model.
Bishop, Chris; Hillier, Susan; Thewlis, Dominic
2017-07-01
Understanding the biomechanics of the foot is essential for many areas of research and clinical practice such as orthotic interventions and footwear development. Despite the widespread attention paid to the biomechanics of the foot during gait, what largely remains unknown is how the foot moves inside the shoe. This study investigated the reliability of the Adelaide In-Shoe Foot Model, which was designed to quantify in-shoe foot kinematics and kinetics during walking. Intra-rater reliability was assessed in 30 participants over five walking trials whilst wearing shoes during two data collection sessions, separated by one week. Sufficient reliability for use was interpreted as a coefficient of multiple correlation and intra-class correlation coefficient of >0.61. Inter-rater reliability was investigated separately in a second sample of 10 adults by two researchers with experience in applying markers for the purpose of motion analysis. The results indicated good consistency in waveform estimation for most kinematic and kinetic data, as well as good inter-and intra-rater reliability. The exception is the peak medial ground reaction force, the minimum abduction angle and the peak abduction/adduction external hindfoot joint moments which resulted in less than acceptable repeatability. Based on our results, the Adelaide in-shoe foot model can be used with confidence for 24 commonly measured biomechanical variables during shod walking. Copyright © 2017 Elsevier B.V. All rights reserved.
Kinematic repeatability of a multi-segment foot model for dance.
Carter, Sarah L; Sato, Nahoko; Hopper, Luke S
2018-03-01
The purpose of this study was to determine the intra and inter-assessor repeatability of a modified Rizzoli Foot Model for analysing the foot kinematics of ballet dancers. Six university-level ballet dancers performed the movements; parallel stance, turnout plié, turnout stance, turnout rise and flex-point-flex. The three-dimensional (3D) position of individual reflective markers and marker triads was used to model the movement of the dancers' tibia, entire foot, hindfoot, midfoot, forefoot and hallux. Intra and inter-assessor reliability demonstrated excellent (ICC ≥ 0.75) repeatability for the first metatarsophalangeal joint in the sagittal plane. Intra-assessor reliability demonstrated excellent (ICC ≥ 0.75) repeatability during flex-point-flex across all inter-segmental angles except for the tibia-hindfoot and hindfoot-midfoot frontal planes. Inter-assessor repeatability ranged from poor to excellent (0.5 > ICC ≥ 0.75) for the 3D segment rotations. The most repeatable measure was the tibia-foot dorsiflexion/plantar flexion articulation whereas the least repeatable measure was the hindfoot-midfoot adduction/abduction articulation. The variation found in the inter-assessor results is likely due to inconsistencies in marker placement. This 3D dance specific multi-segment foot model provides insight into which kinematic measures can be reliably used to ascertain in vivo technical errors and/or biomechanical abnormalities in a dancer's foot motion.
NASA Technical Reports Server (NTRS)
Esparza, V.
1976-01-01
Separation data were obtained at a Mach number of 0.6 and three incidence angles of 4 deg, 6 deg, and 9 deg. The orbiter angle of attack was varied from 0 to 14 degrees. Longitudinal, lateral and normal separation increments were obtained for fixed 747 angles of attack of 0 deg, 2 deg, and 4 deg while varying orbiter angle of attack. Control surface settings on the 747 carrier included rudder deflections of 0 deg and 10 deg and horizontal stabilizer deflections of -1 deg and +5 deg. Photographs of tested configurations are shown.
Low-speed longitudinal and lateral-directional aerodynamic characteristics of the X-31 configuration
NASA Technical Reports Server (NTRS)
Banks, Daniel W.; Gatlin, Gregory M.; Paulson, John W., Jr.
1992-01-01
An experimental investigation of a 19 pct. scale model of the X-31 configuration was completed in the Langley 14 x 22 Foot Subsonic Tunnel. This study was performed to determine the static low speed aerodynamic characteristics of the basic configuration over a large range of angle of attack and sideslip and to study the effects of strakes, leading-edge extensions (wing-body strakes), nose booms, speed-brake deployment, and inlet configurations. The ultimate purpose was to optimize the configuration for high angle of attack and maneuvering-flight conditions. The model was tested at angles of attack from -5 to 67 deg and at sideslip angles from -16 to 16 deg for speeds up to 190 knots (dynamic pressure of 120 psf).
Wezenberg, Daphne; Cutti, Andrea G; Bruno, Antonino; Houdijk, Han
2014-01-01
Decreased push-off power by the prosthetic foot and inadequate roll-over shape of the foot have been shown to increase the energy dissipated during the step-to-step transition in human walking. The aim of this study was to determine whether energy storage and return (ESAR) feet are able to reduce the mechanical energy dissipated during the step-to-step transition. Fifteen males with a unilateral lower-limb amputation walked with their prescribed ESAR foot (Vari-Flex, Ossur; Reykjavik, Iceland) and with a solid-ankle cushioned heel foot (SACH) (1D10, Ottobock; Duderstadt, Germany), while ground reaction forces and kinematics were recorded. The positive mechanical work on the center of mass performed by the trailing prosthetic limb was larger (33%, p = 0.01) and the negative work performed by the leading intact limb was lower (13%, p = 0.04) when walking with the ESAR foot compared with the SACH foot. The reduced step-to-step transition cost coincided with a higher mechanical push-off power generated by the ESAR foot and an extended forward progression of the center of pressure under the prosthetic ESAR foot. Results can explain the proposed improvement in walking economy with this kind of energy storing and return prosthetic foot.
Eerdekens, Maarten; Staes, Filip; Pilkington, Thomas; Deschamps, Kevin
2017-01-01
Application of in-shoe multi-segment foot kinematic analyses currently faces a number of challenges, including: (i) the difficulty to apply regular markers onto the skin, (ii) the necessity for an adequate shoe which fits various foot morphologies and (iii) the need for adequate repeatability throughout a repeated measure condition. The aim of this study therefore was to design novel magnet based 3D printed markers for repeated in-shoe measurements while using accordingly adapted modified shoes for a specific multi-segment foot model. Multi-segment foot kinematics of ten participants were recorded and kinematics of hindfoot, midfoot and forefoot were calculated. Dynamic trials were conducted to check for intra and inter-session repeatability when combining novel markers and modified shoes in a repeated measures design. Intraclass correlation coefficients were calculated to determine reliability. Both repeatability and reliability were proven to be good to excellent with maximum joint angle deviations of 1.11° for intra-session variability and 1.29° for same-day inter-session variability respectively and ICC values of >0.91. The novel markers can be reliably used in future research settings using in-shoe multi-segment foot kinematic analyses with multiple shod conditions.
NASA Technical Reports Server (NTRS)
Re, R. J.; Leavitt, L. D.
1984-01-01
The effects of five geometric design parameters on the internal performance of single-expansion-ramp nozzles were investigated at nozzle pressure ratios up to 10 in the static-test facility of the Langley 16-Foot Transonic Tunnel. The geometric variables on the expansion-ramp surface of the upper flap consisted of ramp chordal angle, ramp length, and initial ramp angle. On the lower flap, the geometric variables consisted of flap angle and flap length. Both internal performance and static-pressure distributions on the centerlines of the upper and lower flaps were obtained for all 43 nozzle configurations tested.
NASA Technical Reports Server (NTRS)
Fox, C. H., Jr.
1978-01-01
A general research fighter model was tested in the Langley 7 by 10 foot high speed tunnel at a Mach number of 0.3. Strakes with exposed semi-spans of 10 percent, 20 percent, and 30 percent of the wing reference semi-span were tested in combination with wings having leading edge sweep angles of 30, 44, and 60 degrees. The angle of attack range was from -4 degrees to approximately 48 degrees at sideslip angles of 0, -5, and 5 degrees. The data are presented without analysis in order to expedite publication.
2016-04-01
Program ft foot/feet GPS Global Positioning System HE High Explosive ID Identification IDA Institute for Defense Analysis IMU Inertial Measurement Unit ISO...were replaced with two ski-shaped runners, and a new mount above the array was used to hold the Inertial Measurement Unit (IMU) and Trimble R8 Real...to collect a cued data measurement (Figure 9). The instrument’s pitch, roll , and yaw angles automatically were measured by the IMU. These angles and
The Achilles Tendon in Healthy Subjects: An Anthropometric and Ultrasound Mapping Study.
Patel, Nick N; Labib, Sameh A
Ultrasonography is an inexpensive, fast, and reliable imaging technique widely used to assess the Achilles tendon. Although significant data exists regarding pathologic tendon changes, ultrasound data from healthy individuals are more limited. We aimed to better characterize ultrasound Achilles tendon measurements in healthy individuals and identify important correlating factors. The information collected included patient demographics, body habitus, activity level, foot dominance, and resting ankle angle. Ultrasound analysis was performed bilaterally on the Achilles tendons of 50 subjects using a high-frequency transducer to measure tendon width, thickness, cross-sectional area, and length. Males had a significantly larger mean tendon length, width, thickness, and cross-sectional area. No statistically significant difference was found in any tendon dimension between the white and black participants. Similarly, no difference was found in any tendon parameter when comparing right versus left leg dominance. Healthy subjects had a mean ankle resting angle of 45.1° ± 24° with no statistically significant difference between right and left ankles. Considering all individuals, each tendon parameter (tendon length, width, thickness, and cross-sectional area) correlated positively with subject height, weight, tibia length, and foot size. Only the Achilles cross-sectional area correlated significantly with the activity level. The resting angle of the ankle correlated positively with both tendon length and thickness. In conclusion, we found significant variations in Achilles tendon anatomy in the healthy adult population. We have thoroughly characterized significant correlations between healthy tendon dimensions and various body habitus, activity levels, and ankle parameters. Greater knowledge of the normal Achilles tendon anatomy and characterization of its variations in the healthy population will potentially allow for better pathologic diagnosis and surgical repair. Copyright © 2017 The American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.
Cobb Angle Progression in Adolescent Scoliosis Begins at the Intervertebral Disc
Will, Ryan E; Stokes, Ian A; Qiu, Xing; Walker, Matthew R.; Sanders, James O
2009-01-01
Study Design Longitudinal radiographic study of patients with progressive idiopathic scoliosis. Objective To determine the relative contributions of vertebral and disc wedging to the increase in Cobb angle during 3 phases of adolescent skeletal growth and maturation. Summary of Background Data Both disc wedging and vertebral body wedging are found in progressive scoliosis, but their relative contribution to curve progression over time is unknown. Which occurs first is important for understanding how scoliosis progresses and for developing methods to halt progression. Previous studies have not properly identified maturity and provide conflicting results. Methods Eighteen girls were followed through their adolescent growth spurt with serial spine and hand skeletal age radiographs. Each Cobb angle was divided into disc wedge angles and vertebral wedge angles. The corresponding hand radiographs provided a measure of maturity level, the Digital Skeletal Age (DSA). The disc versus bone contributions to the Cobb angle were then compared during 3 growth phases: prior to the growth spurt, during the growth spurt and after the growth spurt. Significance of relative changes was assessed with the Wilcoxon two-sided mean rank test. Results Prior to the growth spurt, there was no difference in relative contributions of the disc and the bone (3° vs 0°, p=0.38) to curve progression. During the growth spurt, the mean disc component progressed significantly more than that of the vertebrae (15° vs 0°, p=0.0002). This reversed following the growth spurt with the vertebral component progressing more than the disc (10° vs 0°, p=0.01). Conclusion Adolescent idiopathic scoliosis initially increases through disc wedging during the rapid growth spurt with progressive vertebral wedging occurring later. PMID:19940737
Span-Load Distribution as a Factor in Stability in Roll
NASA Technical Reports Server (NTRS)
Knight, Montgomery; Noyes, Richard W
1932-01-01
This report gives the results of pressure-distribution tests made to study the effects on lateral stability of changing the span-load distribution on a rectangular monoplane wing model of fairly thick section. Three methods of changing the distribution were employed: variation in profile along the span to a thin symmetrical section at the tip, twist from +5 degrees to -15 degrees at the tip, and sweepback from +20 degrees to -20 degrees. The tests were conducted in a 5-foot closed-throat atmospheric wind tunnel. The investigation shows the following results: (1) change in profile along the span from the NACA-84 at the root to the NACA-M2 at the tip considerably reduces lateral instability, but also reduces the general effectiveness of the wing. (2) washout up to 11 degrees progressively reduces maximum lateral instability. (3) transition from sweepforward to sweepback gradually reduces the useful angle-of-attack range, but has no clearly defined effect on maximum lateral instability.
Efficacy of nighttime brace in preventing progression of idiopathic scoliosis of less than 25°.
Lateur, G; Grobost, P; Gerbelot, J; Eid, A; Griffet, J; Courvoisier, A
2017-04-01
The objective of the present study was to assess, at skeletal maturity, the efficacy of non-operative treatment by isolated nighttime brace in the prevention of progression of progressive idiopathic scoliosis of less than 25°. Isolated nighttime brace treatment is effective in the prevention of progression of mild progressive idiopathic scoliosis (Cobb<25°). A single-center retrospective study included 142 patients managed by nighttime brace for progressive idiopathic scoliosis with Cobb angle<25°, with assessment at skeletal maturity. Mean Cobb angle at start of treatment was 15.5° (range, 10-25°). Mean values for Cobb angle and sagittal parameters before treatment and at skeletal maturity were compared on Student t-test. Change in Cobb angle over time was also analyzed. Mean Cobb angle at skeletal maturity was 16.3°, showing significant increase over baseline (15.5°; P=0.04), although the difference was less than the uncertainty of measurement (±6°). In baseline Risser 0 or 1, mean change in Cobb angle at skeletal maturity (16.2°) was not significant (P=0.1). Cobb angle diminished in 26 cases (18%), increased in 24 (17%) and was unchanged in 92 (65%). The present study confirmed the efficacy of non-operative treatment by nighttime brace in mild progressive idiopathic scoliosis (<25°) in a large majority of cases. A nighttime brace thus seems to be an effective option for the treatment of adolescent scoliosis, ensuring a safe curve of around 20°. Level IV, retrospective study. Copyright © 2016 Elsevier Masson SAS. All rights reserved.
Shultz, R; Birmingham, T B; Jenkyn, T R
2011-12-01
This study examined the absolute differences in neutral positions of the joints of the foot with different footwear. This addresses the question of whether separate static trials should be collected for each footwear condition to establish neutral positions. A multi-segment kinematic foot model and optical motion analysis system measured four inter-segmental joints of the foot: (1) hindfoot-to-midfoot in the frontal plane, (2) forefoot-to-midfoot in the frontal plane, (3) hallux-to-forefoot in the sagittal plane, and (4) the height-to-length ratio of the medial longitudinal arch. Barefoot was compared to three shoe condition using Nike Free trainers of varying longitudinal torsional stiffness in ten male volunteers. There was high variability both within subjects and shoe conditions. Shoes in general tended to raise the medial longitudinal arch and dorsiflex the hallux compared to barefoot condition. For the hallux, a minimum important difference of 5° or more was found between shoe conditions and the barefoot condition for majority of the subjects in all three shoe conditions (90% for control, 60% for least stiff, 50% for most stiff). This was less for the frontal plane inter-segmental joints of the foot where 50% of the subjects experience a change above 5° for at least one of the conditions. The choice of using condition-specific neutral trials versus a single common neutral trials should be considered carefully. A single common trial allows for differences in absolute joint angles to be compared between footwear conditions. This can be important clinically to determine whether a joint is approaching its end-of-range and therefore at risk of injury. Several condition-specific neutral trials allows for subtleties in kinematic waveforms to be better compared between conditions, since absolute shifts in joint angles due to changing neutral position are removed and the waveforms are better aligned. Copyright © 2011. Published by Elsevier Ltd.
The 12-foot pressure wind tunnel restoration project model support systems
NASA Technical Reports Server (NTRS)
Sasaki, Glen E.
1992-01-01
The 12 Foot Pressure Wind Tunnel is a variable density, low turbulence wind tunnel that operates at subsonic speeds, and up to six atmospheres total pressure. The restoration of this facility is of critical importance to the future of the U.S. aerospace industry. As part of this project, several state of the art model support systems are furnished to provide an optimal balance between aerodynamic and operational efficiency parameters. Two model support systems, the Rear Strut Model Support, and the High Angle of Attack Model Support are discussed. This paper covers design parameters, constraints, development, description, and component selection.
NASA Technical Reports Server (NTRS)
Bare, E. A.; Berrier, B. L.; Capone, F. J.
1981-01-01
Investigations were conducted in the Langley 16-Foot Transonic Tunnel to provide data on a 0.10-scale model of the prototype F-18 airplane and a 0.047-scale model of the F-15 three-surface configuration (canard, wing, and horizontal tails). Test data were obtained at static conditions and at Mach numbers from 0.6 to 1.2 over an angle-of-attack range from 2 deg to 15 deg. Nozzle pressure ratio was varied from jet off to about 8.0.
Tests of a 1/7-Scale Semispan Model of the XB-35 Airplane in the Langley 19-Foot Pressure Tunnel
NASA Technical Reports Server (NTRS)
Teplitz, Jerome; Kayten, Gerald G.; Cancro, Patrick A.
1946-01-01
A 1/7 scale semispan model of the XB-35 airplane was tested in the Langley 10 foot pressure tunnel, primarily for the purpose of investigating the effectiveness of a leading-edge slot for alleviation of stick-fixed longitudinal instability at high angles of attack caused by early tip stalling and a device for relief of stick-free instability caused by elevon up-floating tendencies at high angles of attack. Results indicated that the slot was not adequate to provide the desired improvement in stick-fixed stability. The tab-flipper device provided improvement in stick-free stability abd two of the linkage combinations tested gave satisfactory variations of control force with airspeed for all conditions except that in which the wing-tip "pitch-control" flap was fully deflected. However, the improvement in control force characteristics was accompanied by a detrimental effect on stick-fixed stability because of the pitching moments produced by the elevon tab deflection.
Unsteady density and velocity measurements in the 6 foot x 6 foot wind tunnel
NASA Technical Reports Server (NTRS)
Rose, W. C.; Johnson, D. A.
1980-01-01
The methods used and the results obtained in four aero-optic tests are summarized. It is concluded that the rather large values of density fluctuation appear to be the result of much higher Mach number than freestream and the violent turbulence in the flow as it separates from the turret. A representative comparison of fairing on-fairing off rms density fluctuation indicates essentially no effect at M = 0.62 and a small effect at M = 0.95. These data indicate that some slight improvement in optical quality can be expected with the addition of a fairing, although at M = 0.62 its effect would be nil. Fairings are very useful in controlling pressure loads on turrets, but will not have first order effects on optical quality. Scale sizes increase dramatically with increasing azimuth angle for a reprensentative condition. Since both scale sizes and fluctuation levels increase (total turbulence path length also increases) with azimuth angle, substantial optical degradation might be expected. For shorter wave lengths, large degradations occur.
NASA Technical Reports Server (NTRS)
Hawthorne, P. J.
1976-01-01
Data obtained in a wind tunnel test were examined to: (1) obtain pressure distributions, forces and moments over the vehicle 5 Orbiter in the terminal area energy management (TAEM) and approach phases of flight; (2) obtain elevon and rudder hinge moments in the TAEM and approach phases of flight; (3) obtain body flap and elevon loads for verification of loads balancing with integrated pressure distributions; and (4) obtain pressure distributions near the short OMS pods in the high subsonic, transonic and low supersonic Mach number regimes. Testing was conducted over a Mach number range from 0.6 to 1.4 with Reynolds number variations from 7.57 x 1 million to 2.74 x 1 million per foot. Model angle of attack was varied from -4 to 16 degrees and angles of sideslip ranged from -8 to 8 degrees.
Study of Wearable Knee Assistive Instruments for Walk Rehabilitation
NASA Astrophysics Data System (ADS)
Zhu, Yong; Nakamura, Masahiro; Ito, Noritaka; Fujimoto, Hiroshi; Horikuchi, Kenichi; Wakabayashi, Shojiro; Takahashi, Rei; Terada, Hidetsugu; Haro, Hirotaka
A wearable Knee Assistive Instrument for the walk rehabilitation was newly developed. Especially, this system aimed at supporting the rehabilitation for the post-TKA (Total Knee Arthroplasty) which is a popular surgery for aging people. This system consisted of an assisting mechanism for the knee joint, a hip joint support system and a foot pressure sensor system. The driving system of this robot consisted of a CPU board which generated the walking pattern, a Li-ion battery, DC motors with motor drivers, contact sensors to detect the state of foot and potentiometers to detect the hip joint angle. The control method was proposed to reproduce complex motion of knee joint as much as possible, and to increase hip or knee flexion angle. Especially, this method used the timing that heel left from the floor. This method included that the lower limb was raised to prevent a subject's fall. Also, the prototype of knee assisting system was tested. It was confirmed that the assisting system is useful.
15. DETAIL OF WORKS PROGRESS ADMINISTRATION (WPA) MONUMENT LOCATED ON ...
15. DETAIL OF WORKS PROGRESS ADMINISTRATION (WPA) MONUMENT LOCATED ON TOP OF BANK JUST SOUTH OF NORTH FOOT BRIDGE - Upper Doughty Dam, 200 feet west of Garden State Parkway, 1.7 miles west of Absecon, Egg Harbor City, Atlantic County, NJ
Barisch-Fritz, Bettina; Schmeltzpfenning, Timo; Plank, Clemens; Grau, Stefan
2014-01-01
The complex functions of feet require a specific composition, which is progressively achieved by developmental processes. This development should take place without being affected by footwear. The aim of this study is to evaluate differences between static and dynamic foot morphology in developing feet. Feet of 2554 participants (6-16 years) were recorded using a new scanner system (DynaScan4D). Each foot was recorded in static half and full weight-bearing and during walking. Several foot measures corresponding to those used in last construction were calculated. The differences were identified by one-way ANOVA and paired Student's t-test. Static and dynamic values of each foot measure must be considered to improve the fit of footwear. In particular, footwear must account for the increase of forefoot width and the decrease of midfoot girth. Furthermore, the toe box should have a more rounded shape. The findings are important for the construction of footwear for developing feet.
The potential of ultrasonography in the evaluation of foot orthotics therapy.
Petcu, Daniel; Mitrea, Delia Alexandrina; Bondor, Cosmina Ioana; Perciun, Elena Rodica
2017-11-29
Foot orthotics prescription is based on the foot functioning paradigms with tissue stress theory being in avant-garde. The main goal of orthotic therapy is to reduce the internal tissue's pathological stresses in the foot structures. Traditionally, ultrasound scanning technique depicts anatomic related data of both common and uncommon pathology encountered in the clinical practice, helping in diagnosing, treating and evaluating, which are equally important for the practitioners. Its accessibility, compared to biomechanical modelling, makes this technique a valuable tool in the field of foot and ankle disorders. Despite its user-dependent limitation, the ongoing technical progress improves the ability of ultrasonography as a highly advanced procedure in musculoskeletal imaging, being also a valuable searching tool for musculotendinous mechanics or morphological changes as a result of a conservative intervention. The aim of the present work was to perform a review of the state of the art concerning the usefulness of ultrasonography in the study of foot orthotic therapy and to analyze its effectiveness.
Landsman, A S; Meaney, D F; Cargill, R S; Macarak, E J; Thibault, L E
1995-10-01
Foot ulcerations are one of the most common and dangerous complications associated with chronic diabetes mellitus. Many studies have focused on neuropathy, in conjunction with elevated ground reactive forces, as the principal cause of these ulcerations. The authors discuss the mechanical cause of diabetic ulcerations at the cellular level. It is hypothesized that increased rate of tissue deformation associated with foot slap secondary to progressive motor neuropathy is the actual culprit, and not the magnitude of local pressure applied. The authors present a cellular model that shows that high rates of tissue deformation may result in elevated intracellular calcium concentrations, which may lead to cellular death, while comparable loads gradually applied do not. Furthermore, there is no significant difference in the response observed at 5 psi and 10 psi. Based on these findings, it is hypothesized that techniques such as ankle foot orthoses, which control the velocity of foot strike, may be useful in treating diabetic foot ulcerations.
Foot osteoarthritis: latest evidence and developments
Roddy, Edward; Menz, Hylton B.
2018-01-01
Foot osteoarthritis (OA) is a common problem in older adults yet is under-researched compared to knee or hand OA. Most existing studies focus on the first metatarsophalangeal joint, with evidence relating to midfoot OA being particularly sparse. Symptomatic radiographic foot OA affects 17% of adults aged 50 years and over. The first metatarsophalangeal joint is most commonly affected, followed by the second cuneometatarsal and talonavicular joints. Epidemiological studies suggest the existence of distinct first metatarsophalangeal joint and polyarticular phenotypes, which have differing clinical and risk factor profiles. There are few randomized controlled trials in foot OA. Existing trials provide some evidence of the effectiveness for pain relief of physical therapy, rocker-sole shoes, foot orthoses and surgical interventions in first metatarsophalangeal joint OA and prefabricated orthoses in midfoot OA. Prospective epidemiological studies and randomized trials are needed to establish the incidence, progression and prognosis of foot OA and determine the effectiveness of both commonly used and more novel interventions. PMID:29619094
The Diabetic Foot Attack: "'Tis Too Late to Retreat!"
Vas, Prashanth R J; Edmonds, Michael; Kavarthapu, Venu; Rashid, Hisham; Ahluwalia, Raju; Pankhurst, Christian; Papanas, Nikolaos
2018-03-01
The "diabetic foot attack" is one of the most devastating presentations of diabetic foot disease, typically presenting as an acutely inflamed foot with rapidly progressive skin and tissue necrosis, at times associated with significant systemic symptoms. Without intervention, it may escalate over hours to limb-threatening proportions and poses a high amputation risk. There are only best practice approaches but no international protocols to guide management. Immediate recognition of a typical infected diabetic foot attack, predominated by severe infection, with prompt surgical intervention to debride all infected tissue alongside broad-spectrum antibiotic therapy is vital to ensure both limb and patient survival. Postoperative access to multidisciplinary and advanced wound care therapies is also necessary. More subtle forms exist: these include the ischemic diabetic foot attack and, possibly, in a contemporary categorization, acute Charcot neuroarthropathy. To emphasize the importance of timely action especially in the infected and ischemic diabetic foot attack, we revisit the concept of "time is tissue" and draw parallels with advances in acute myocardial infarction and stroke care. At the moment, international protocols to guide management of severe diabetic foot presentations do not specifically use the term. However, we believe that it may help increase awareness of the urgent actions required in some situations.
Gait patterns in hemiplegic patients with equinus foot deformity.
Manca, M; Ferraresi, G; Cosma, M; Cavazzuti, L; Morelli, M; Benedetti, M G
2014-01-01
Equinus deformity of the foot is a common feature of hemiplegia, which impairs the gait pattern of patients. The aim of the present study was to explore the role of ankle-foot deformity in gait impairment. A hierarchical cluster analysis was used to classify the gait patterns of 49 chronic hemiplegic patients with equinus deformity of the foot, based on temporal-distance parameters and joint kinematic measures obtained by an innovative protocol for motion assessment in the sagittal, frontal, and transverse planes, synthesized by parametrical analysis. Cluster analysis identified five subgroups of patients with homogenous levels of dysfunction during gait. Specific joint kinematic abnormalities were found, according to the speed of progression in each cluster. Patients with faster walking were those with less ankle-foot complex impairment or with reduced range of motion of ankle-foot complex, that is with a stiff ankle-foot complex. Slow walking was typical of patients with ankle-foot complex instability (i.e., larger motion in all the planes), severe equinus and hip internal rotation pattern, and patients with hip external rotation pattern. Clustering of gait patterns in these patients is helpful for a better understanding of dysfunction during gait and delivering more targeted treatment.
Age-related differences in women's foot shape.
Ansuategui Echeita, Jone; Hijmans, Juha M; Smits, Sharon; Van der Woude, Lucas H V; Postema, Klaas
2016-12-01
Describe age-related differences in women's foot shape using a wide range of measurements and ages. Cross-sectional, observational study. Six foot-shape measurements of each foot: foot lengths, ball widths, ball circumferences, low instep circumferences, high instep circumferences, and heel instep circumference. 168 women from 20 to over 80 years of age, divided into seven age categories, were included. Older women had significantly greater foot-shape measurements, even after adjusting for Body Mass Index. Ball widths increased 3.1-4.0mm per decade, ball circumferences 5.6-7.4mm per decade, high instep circumferences 0.4-4.8mm per decade, and heel instep circumferences 1.8-1.9mm per decade. Ball widths, ball circumferences, and left high instep circumference plateaued in the 70-75 years-of-age category, and decreased in the oldest age category. For low instep circumference, age did not prevail significantly over Body Mass Index. Foot length was not associated with age. This study described women's progressive foot-shape changes with age. The findings provide a better understanding of foot-shape changes, mainly found in the forefoot. It demonstrates that for a good fit, shoe design for older adults and for younger adults should differ. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Effect of static foot posture on the dynamic stiffness of foot joints during walking.
Sanchis-Sales, E; Sancho-Bru, J L; Roda-Sales, A; Pascual-Huerta, J
2018-05-01
The static foot posture has been related to the development of lower limb injuries. This study aimed to investigate the dynamic stiffness of foot joints during gait in the sagittal plane to understand the role of the static foot posture in the development of injuries. Seventy healthy adult male subjects with different static postures, assessed by the Foot Posture Index (FPI) (30 normal, 20 highly pronated and 20 highly supinated), were recruited. Kinematic and kinetic data were recorded using an optical motion capture system and a pressure platform, and dynamic stiffness at the different stages of the stance was calculated from the slopes of the linear regression on the flexion moment-angle curves. The effect of foot type on dynamic stiffness and on ranges of motion and moments was analysed using ANOVAs and post-hoc tests, and linear correlation between dynamic stiffness and FPI was also tested. Highly pronated feet showed a significantly smaller range of motion at the ankle and metatarsophalangeal joints and also a larger range of moments at the metatarsophalangeal joint than highly supinated feet. Dynamic stiffness during propulsion was significantly greater at all foot joints for highly pronated feet, with positive significant correlations with the squared FPI. Highly supinated feet showed greater dynamic stiffness than normal feet, although to a lesser extent. Highly pronated feet during normal gait experienced the greatest decrease in the dorsiflexor moments during propulsion, normal feet being the most balanced regarding work generated and absorbed. Extreme static foot postures show greater dynamic stiffness during propulsion and greater absorbed work, which increases the risk of developing injuries. The data presented may be used when designing orthotics or prostheses, and also when planning surgery that modifies joint stiffness. Copyright © 2018 Elsevier B.V. All rights reserved.
Teng, P S P; Kong, P W; Leong, K F
2017-06-01
Non-contact anterior cruciate ligament (ACL) injuries commonly occur when athletes land in high risk positions such as knee valgus. The position of the foot at landing may influence the transmission of forces from the ankle to the knee. Using an experimental approach to manipulate foot rotation positions, this study aimed to provide new insights on how knee valgus during single-leg landing may be influenced by foot positions. Eleven male recreational basketball players performed single-leg drop landings from a 30-cm high platform in three foot rotation positions (toe-in, toe-forward and toe-out) at initial contact. A motion capture system and a force plate were used to measure lower extremity kinematics and kinetics. Knee valgus angles at initial contact (KVA) and maximum knee valgus moments (KVM), which were known risk factors associated with ACL injury, were measured. A one-way repeated measures Analysis of Variance was conducted (α=0.05) to compare among the three foot positions. Foot rotation positions were found to have a significant effect on KVA (p<0.001, η 2 =0.66) but the difference between conditions (about 1°) was small and not clinically meaningful. There was a significant effect of foot position on KVM (p<0.001, η 2 =0.55), with increased moment observed in the toe-out position as compared to toe-forward (p=0.012) or toe-in positions (p=0.002). When landing with one leg, athletes should avoid extreme toe-out foot rotation positions to minimise undesirable knee valgus loading associated with non-contact ACL injury risks. Copyright © 2017 Elsevier B.V. All rights reserved.
Sung, Ki Hyuk; Chung, Chin Youb; Lee, Kyoung Min; Lee, Seung Yeol; Park, Moon Seok
2013-09-01
This study was performed to investigate anterior ankle impingement after tendo-Achilles lengthening for long-standing equinus deformity in patients with residual poliomyelitis and to investigate whether the severity of preoperative equinus deformity affected the occurrence of symptomatic anterior impingement. Twenty-seven consecutive patients (mean age, 43.8 ± 9.4 years) with residual poliomyelitis who underwent tendo-Achilles lengthening for equinus foot deformity were included. On lateral foot-ankle weight-bearing radiographs, the tibiocalcaneal angle, plantigrade angle, and McDermott grade were measured and the presence of anterior blocking spur was evaluated. Eleven patients (40.7%) had anterior ankle impingement on radiographic findings preoperatively and 24 patients (88.9%) at latest follow-up. There was a significant difference in McDermott grade between preoperative and latest follow-up (P < .001). There were significant differences in tibiocalcaneal angle and plantigrade angle between the patients with anterior ankle pain and without anterior ankle pain (P = .006 and .011, respectively) and between the patients with anterior blocking spur and without anterior blocking spur (P = .005 and .010, respectively). Most patients with residual poliomyelitis had anterior ankle impingement after tendo-Achilles lengthening for long-standing equinus deformity, and the presence of symptomatic anterior ankle impingement was significantly associated with the severity of the equinus deformity. Therefore, for residual poliomyelitis patients with severe long-standing equinus deformity, surgeons should consider the possibility of a subsequent anterior procedure for anterior impingement after tendo-Achilles lengthening. Level IV, retrospective case series.
Locomotor Behavior of Chickens Anticipating Incline Walking
LeBlanc, Chantal; Tobalske, Bret; Szkotnicki, Bill; Harlander-Matauschek, Alexandra
2018-01-01
Keel bone damage (KBD) is prevalent in hens raised for egg production, and ramps between different tiers in aviaries have potential to reduce the frequency of falls resulting in KBD. Effective use of ramps requires modulation of locomotion in anticipation of the incline. Inadequate adaptive locomotion may be one explanation why domestic layer hens (Gallus gallus domesticus) exhibit high rates of KBD. To improve understanding of the capacity of hens to modulate their locomotion in anticipation of climbing, we measured the effects of incline angle upon the mechanics of the preparatory step before ascending a ramp. Because the energetic challenge of climbing increases with slope, we predicted that as angle of incline increased, birds during foot contact with the ground before starting to climb would increase their peak force and duration of contact and reduce variation in center of pressure (COP) under their foot. We tested 20 female domestic chickens on ramp inclines at slopes of +0°, +40°, and +70° when birds were 17, 21, 26, 31, and 36 weeks of age. There were significantly higher vertical peak ground reaction forces in preparation at the steepest slope, and ground contact time increased significantly with each increase in ramp angle. Effects upon variation in COP were not apparent; likewise, effects of limb length, age, body mass were not significant. Our results reveal that domestic chickens are capable of modulating their locomotion in response to incline angle. PMID:29376060
Kobayashi, Toshiki; Orendurff, Michael S.; Hunt, Grace; Lincoln, Lucas S.; Gao, Fan; LeCursi, Nicholas; Foreman, K. Bo
2017-01-01
Mechanical properties of an articulated ankle-foot orthosis (AFO) are closely related to gait performance in individuals post-stroke. This paper presents a pilot study on the mechanical properties of a novel articulated AFO with adjustable plantarflexion resistance, dorsiflexion resistance and alignment, and its effect on ankle and knee joint kinematics and kinetics in an individual post-stroke during gait. The mechanical properties of the AFO were quantified. Gait analysis was performed using a 3D motion capture system with a split-belt instrumented treadmill under 12 different settings of the mechanical properties of the AFO [i.e. 4 plantarflexion resistances (P1
Clinical study of symbrachydactyly of the foot.
Uchida, T; Kojima, T; Hirakawa, M
1995-07-01
Seventeen patients with symbrachydactyly of the foot are described. Patient characteristics including sex, the side of the affected foot, age at first medical examination, and condition of the nails were recorded. Compared with the unaffected side, the lengths of the proximal phalangeal and metatarsal bones were significantly shorter. The abnormalities of the feet were classified into four types: typical axial, atypical axial, medial ray, and rudimentary. The anomaly progresses from hypoplasia of the central rays to a deformity of the great toe, but rarely involves the fifth toe. The fact that this differs from symbrachydactyly of the hand is of considerable interest.
Milner, Clare E; Brindle, Richard A
2016-01-01
There has been increased interest recently in measuring kinematics within the foot during gait. While several multisegment foot models have appeared in the literature, the Oxford foot model has been used frequently for both walking and running. Several studies have reported the reliability for the Oxford foot model, but most studies to date have reported reliability for barefoot walking. The purpose of this study was to determine between-day (intra-rater) and within-session (inter-trial) reliability of the modified Oxford foot model during shod walking and running and calculate minimum detectable difference for common variables of interest. Healthy adult male runners participated. Participants ran and walked in the gait laboratory for five trials of each. Three-dimensional gait analysis was conducted and foot and ankle joint angle time series data were calculated. Participants returned for a second gait analysis at least 5 days later. Intraclass correlation coefficients and minimum detectable difference were determined for walking and for running, to indicate both within-session and between-day reliability. Overall, relative variables were more reliable than absolute variables, and within-session reliability was greater than between-day reliability. Between-day intraclass correlation coefficients were comparable to those reported previously for adults walking barefoot. It is an extension in the use of the Oxford foot model to incorporate wearing a shoe while maintaining marker placement directly on the skin for each segment. These reliability data for walking and running will aid in the determination of meaningful differences in studies which use this model during shod gait. Copyright © 2015 Elsevier B.V. All rights reserved.
A simple field method to identify foot strike pattern during running.
Giandolini, Marlène; Poupard, Thibaut; Gimenez, Philippe; Horvais, Nicolas; Millet, Guillaume Y; Morin, Jean-Benoît; Samozino, Pierre
2014-05-07
Identifying foot strike patterns in running is an important issue for sport clinicians, coaches and footwear industrials. Current methods allow the monitoring of either many steps in laboratory conditions or only a few steps in the field. Because measuring running biomechanics during actual practice is critical, our purpose is to validate a method aiming at identifying foot strike patterns during continuous field measurements. Based on heel and metatarsal accelerations, this method requires two uniaxial accelerometers. The time between heel and metatarsal acceleration peaks (THM) was compared to the foot strike angle in the sagittal plane (αfoot) obtained by 2D video analysis for various conditions of speed, slope, footwear, foot strike and state of fatigue. Acceleration and kinematic measurements were performed at 1000Hz and 120Hz, respectively, during 2-min treadmill running bouts. Significant correlations were observed between THM and αfoot for 14 out of 15 conditions. The overall correlation coefficient was r=0.916 (P<0.0001, n=288). The THM method is thus highly reliable for a wide range of speeds and slopes, and for all types of foot strike except for extreme forefoot strike during which the heel rarely or never strikes the ground, and for different footwears and states of fatigue. We proposed a classification based on THM: FFS<-5.49ms
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 6 2010-10-01 2010-10-01 false Definitions. 523.2 Section 523.2 Transportation..., DEPARTMENT OF TRANSPORTATION VEHICLE CLASSIFICATION § 523.2 Definitions. Approach angle means the smallest... to the nearest tenth of a square foot. For purposes of this definition, track width is the lateral...
A radiographic assessment of lumbar spine posture in four different upright standing positions.
Gallagher, Kaitlin M; Sehl, Michael; Callaghan, Jack P
2016-08-01
Approximately 50% of a sample population will develop prolonged standing induced low back pain. The cause of this pain may be due to their lumbar spine posture. The purpose of this study was to investigate differences in lumbar posture between 17 participants categorized as a pain or non-pain developers during level ground standing. A secondary purpose was to evaluate the influence of two standing aids (an elevated surface to act as a foot rest and declined sloped surface) on lumbopelvic posture. Four sagittal plane radiographs were taken: a normal standing position on level ground, when using an elevated foot rest, using a declined sloped surface, and maximum lumbar spine extension as a reference posture. Lumbosacral lordosis, total lumbar lordosis, and L1/L2 and L5/S1 intervertebral joint angles were measured on each radiograph. There was a significant difference between the lumbosacral lordosis angle and L5/S1 angles in upright versus maximum extension; however, this was independent of pain group. The elevated surface was most effective at causing lumbosacral spine flexion. Potentially successful postures for eliminating low back pain during prolonged standing mainly influence the lower lumbar lordosis. Future work should assess the influence of hip posture on low back pain development during standing. Copyright © 2016 Elsevier Ltd. All rights reserved.
Forefoot Adduction Is a Risk Factor for Jones Fracture.
Fleischer, Adam E; Stack, Rebecca; Klein, Erin E; Baker, Jeffrey R; Weil, Lowell; Weil, Lowell Scott
Jones fractures are among the most common fractures of the foot; however, much remains unknown about their etiology. The purpose of the present study was to further examine the risk factors of forefoot and hindfoot alignment on Jones fractures using an epidemiologic study design. We used a retrospective, matched, case-control study design. Cases consisted of patients with acute, isolated Jones fractures confirmed on plain film radiographs seen at our institute from January 2009 to December 2013. Patients presenting with pain unrelated to metatarsal fractures served as controls. Controls were matched to cases by age (±2 years), gender, and year of presentation. Weightbearing foot radiographs were assessed for 13 angular relationships by a single rater. Conditional multivariable logistic regression was used to identify important risk factors. Fifty patients with acute Jones fractures and 200 controls were included. The only significant variables in the final multivariable model were the metatarsus adductus angle (odds ratio [OR] 1.16, 95% confidence interval [CI] 1.08 to 1.25) and fourth/fifth intermetatarsal angle (OR 0.69, 95% CI 0.57 to 0.83)-both measures of static forefoot adduction. The presence of metatarsus adductus (defined as >15°) on foot radiographs was associated with a 2.4 times greater risk of a Jones fracture (adjusted OR 2.4, 95% CI 1.2 to 4.8). We have concluded that the risk of Jones fracture increases with an adducted forefoot posture. In our population, which consisted primarily of patients presenting after a fall (10 of 50; 20%) or misstep/inversion injury (19 of 50; 38%), the hindfoot alignment appeared to be a less important factor. Copyright © 2017 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.
Papuga, M Owen; Burke, Jeanmarie R
2011-02-01
An ink pad and paper, pressure-sensitive platforms, and photography have previously been used to collect footprint data used in clinical assessment. Digital scanners have been widely used more recently to collect such data. The purpose of this study was to evaluate the intra- and interrater reliability of a flatbed digital image scanning technology to capture footprint data. This study used a repeated-measures design on 32 (16 male 16 female) healthy subjects. The following measured indices of footprint were recorded from 2-dimensional images of the plantar surface of the foot recorded with an Associate Platinum (Foot Levelers Inc, Roanoke, VA) digital foot scanner: Staheli index, Chippaux-Smirak index, arch angle, and arch index. Intraclass correlation coefficient (ICC) values were calculated to evaluate intrarater, interday, and interclinician reliability. The ICC values for intrarater reliability were greater than or equal to .817, indicating an excellent level of reproducibility in assessing the collected images. Analyses of variance revealed that there were no significant differences between raters for each index (P > .05). The ICC values also indicated excellent reliability (.881-.971) between days and clinicians in all but one of the indices of footprint, arch angle (.689), with good reliability between clinicians. The full-factorial analysis of variance model did not reveal any interaction effects (P > .05), which indicated that indices of footprint were not changing across days and clinicians. Scanning technology used in this study demonstrated good intra- and interrater reliability measurements of footprint indices, as demonstrated by high ICC values. Copyright © 2011 National University of Health Sciences. Published by Mosby, Inc. All rights reserved.
Cheng, Hsin-Yi Kathy; Lin, Chun-Li; Wang, Hsien-Wen; Chou, Shih-Wei
2008-01-01
Stretching plays an important role in the treatment of plantar fasciitis. Information on the internal stresses/strains of the plantar fascia under stretch is useful in enhancing knowledge on the stretch mechanisms. Although direct measurement can monitor plantar fascia changes, it is invasive and gathers only localized information. The purpose of this paper was to construct a three-dimensional finite element model of the foot to calculate the stretch effects on plantar fascia and monitor its stress/strain distributions and concentrations. A three-dimensional foot model was developed and contained 26 bones with joint cartilages, 67 ligaments and a fan-like solid plantar fascia modeling. All tissues were idealized as linear elastic, homogeneous and isotropic whilst the plantar fascia was assigned as hyperelastic to represent its nonlinearity. The plantar fascia was monitored for its biomechanical responses under various stretch combinations: three toe dorsiflexion angles (windlass effect: 15 degrees , 30 degrees and 45 degrees ) and five Achilles tendon forces (100, 200, 300, 400 and 500N). Our results indicated that the plantar fascia strain increased as the dorsiflexion angles increased, and this phenomenon was enhanced by increasing Achilles tendon force. A stress concentration was found near the medial calcaneal tubercle, and the fascia stress was higher underneath the first foot ray and gradually decreased as it moved toward the fifth ray. The current model recreated the position of the foot when stretch is placed on the plantar fascia. The results provided a general insight into the mechanical and biomechanical aspects of the influences of windlass mechanism and Achilles tendon force on plantar fascia stress and strain distribution. These findings might have practical implications onto plantar fascia stretch approaches, and provide guidelines to its surgical release.
Hollander, Karsten; Argubi-Wollesen, Andreas; Reer, Rüdiger; Zech, Astrid
2015-01-01
Possible benefits of barefoot running have been widely discussed in recent years. Uncertainty exists about which footwear strategy adequately simulates barefoot running kinematics. The objective of this study was to investigate the effects of athletic footwear with different minimalist strategies on running kinematics. Thirty-five distance runners (22 males, 13 females, 27.9 ± 6.2 years, 179.2 ± 8.4 cm, 73.4 ± 12.1 kg, 24.9 ± 10.9 km.week-1) performed a treadmill protocol at three running velocities (2.22, 2.78 and 3.33 m.s-1) using four footwear conditions: barefoot, uncushioned minimalist shoes, cushioned minimalist shoes, and standard running shoes. 3D kinematic analysis was performed to determine ankle and knee angles at initial foot-ground contact, rate of rear-foot strikes, stride frequency and step length. Ankle angle at foot strike, step length and stride frequency were significantly influenced by footwear conditions (p<0.001) at all running velocities. Posthoc pairwise comparisons showed significant differences (p<0.001) between running barefoot and all shod situations as well as between the uncushioned minimalistic shoe and both cushioned shoe conditions. The rate of rear-foot strikes was lowest during barefoot running (58.6% at 3.33 m.s-1), followed by running with uncushioned minimalist shoes (62.9%), cushioned minimalist (88.6%) and standard shoes (94.3%). Aside from showing the influence of shod conditions on running kinematics, this study helps to elucidate differences between footwear marked as minimalist shoes and their ability to mimic barefoot running adequately. These findings have implications on the use of footwear applied in future research debating the topic of barefoot or minimalist shoe running. PMID:26011042
Hollander, Karsten; Argubi-Wollesen, Andreas; Reer, Rüdiger; Zech, Astrid
2015-01-01
Possible benefits of barefoot running have been widely discussed in recent years. Uncertainty exists about which footwear strategy adequately simulates barefoot running kinematics. The objective of this study was to investigate the effects of athletic footwear with different minimalist strategies on running kinematics. Thirty-five distance runners (22 males, 13 females, 27.9 ± 6.2 years, 179.2 ± 8.4 cm, 73.4 ± 12.1 kg, 24.9 ± 10.9 km x week(-1)) performed a treadmill protocol at three running velocities (2.22, 2.78 and 3.33 m x s(-1)) using four footwear conditions: barefoot, uncushioned minimalist shoes, cushioned minimalist shoes, and standard running shoes. 3D kinematic analysis was performed to determine ankle and knee angles at initial foot-ground contact, rate of rear-foot strikes, stride frequency and step length. Ankle angle at foot strike, step length and stride frequency were significantly influenced by footwear conditions (p<0.001) at all running velocities. Posthoc pairwise comparisons showed significant differences (p<0.001) between running barefoot and all shod situations as well as between the uncushioned minimalistic shoe and both cushioned shoe conditions. The rate of rear-foot strikes was lowest during barefoot running (58.6% at 3.33 m x s(-1)), followed by running with uncushioned minimalist shoes (62.9%), cushioned minimalist (88.6%) and standard shoes (94.3%). Aside from showing the influence of shod conditions on running kinematics, this study helps to elucidate differences between footwear marked as minimalist shoes and their ability to mimic barefoot running adequately. These findings have implications on the use of footwear applied in future research debating the topic of barefoot or minimalist shoe running.
Zhou, Haichao; Ren, Haoyang; Li, Chunguang; Xia, Jiang; Yu, Guangrong; Yang, Yunfeng
2017-01-01
Purpose . To investigate the effect of cuboid osteotomy lateral column lengthening (LCL) for the correction of stage II B adult-acquired flatfoot deformity in cadaver. Methods . Six cadaver specimens were loaded to 350 N. Flatfoot models were established and each was evaluated radiographically and pedobarographically in the following conditions: (1) intact foot, (2) flatfoot, and (3) cuboid osteotomy LCL (2, 3, 4, and 5 mm). Results . Compared with the flatfoot model, the LCLs showed significant correction of talonavicular coverage on anteroposterior radiographs and talus-first metatarsal angle on both anteroposterior and lateral radiographs ( p < .05). Compared with the intact foot, the above angles of the LCLs showed no significant difference except the 2 mm LCL. In terms of forefoot pressure, medial pressure of the 2 mm LCL ( p = .044) and lateral pressure of the 3, 4, and 5 mm LCLs showed statistical differences ( p < .05), but lateral pressure of the 3 mm LCL was not more than the intact foot as compared to the 4 and 5 mm LCLs, which was less than medial pressure. Conclusion . Cuboid osteotomy LCL procedure avoids damage to subtalar joint and has a good effect on correction of stage II B adult-acquired flatfoot deformity with a 3 mm lengthening in cadavers.
Zhou, Haichao; Ren, Haoyang; Li, Chunguang; Xia, Jiang; Yu, Guangrong
2017-01-01
Purpose. To investigate the effect of cuboid osteotomy lateral column lengthening (LCL) for the correction of stage II B adult-acquired flatfoot deformity in cadaver. Methods. Six cadaver specimens were loaded to 350 N. Flatfoot models were established and each was evaluated radiographically and pedobarographically in the following conditions: (1) intact foot, (2) flatfoot, and (3) cuboid osteotomy LCL (2, 3, 4, and 5 mm). Results. Compared with the flatfoot model, the LCLs showed significant correction of talonavicular coverage on anteroposterior radiographs and talus-first metatarsal angle on both anteroposterior and lateral radiographs (p < .05). Compared with the intact foot, the above angles of the LCLs showed no significant difference except the 2 mm LCL. In terms of forefoot pressure, medial pressure of the 2 mm LCL (p = .044) and lateral pressure of the 3, 4, and 5 mm LCLs showed statistical differences (p < .05), but lateral pressure of the 3 mm LCL was not more than the intact foot as compared to the 4 and 5 mm LCLs, which was less than medial pressure. Conclusion. Cuboid osteotomy LCL procedure avoids damage to subtalar joint and has a good effect on correction of stage II B adult-acquired flatfoot deformity with a 3 mm lengthening in cadavers. PMID:28497049
NASA Technical Reports Server (NTRS)
Shinoda, Patrick M.
1994-01-01
A full-scale helicopter rotor test was conducted in the NASA Ames 80- by 120-Foot Wind Tunnel with a four-bladed S-76 rotor system. This wind tunnel test generated a unique and extensive data base covering a wide range of rotor shaft angles-of-attack and rotor thrust conditions from 0 to 100 knots. Three configurations were tested: (1) empty tunnel; (2) test stand body (fuselage) and support system; and (3) fuselage and support system with rotor installed. Empty tunnel wall pressure data are evaluated as a function of tunnel speed to understand the baseline characteristics. Aerodynamic interaction effects between the fuselage and the walls of the tunnel are investigated by comparing wall, ceiling, and floor pressures for various tunnel velocities and fuselage angles-of-attack. Aerodynamic interaction effects between the rotor and the walls of the tunnel are also investigated by comparing wall, ceiling, and floor pressures for various rotor shaft angles, rotor thrust conditions, and tunnel velocities. Empty tunnel wall pressure data show good repeatability and are not affected by tunnel speed. In addition, the tunnel wall pressure profiles are not affected by the presence of the fuselage apart from a pressure shift. Results do not indicate that the tunnel wall pressure profiles are affected by the presence of the rotor. Significant changes in the wall, ceiling, and floor pressure profiles occur with changing tunnel speeds for constant rotor thrust and shaft angle conditions. Significant changes were also observed when varying rotor thrust or rotor shaft angle-of-attack. Other results indicate that dynamic rotor loads and blade motion are influenced by the presence of the tunnel walls at very low tunnel velocity and, together with the wall pressure data, provide a good indication of flow breakdown.
NASA Technical Reports Server (NTRS)
Carson, George T., Jr.; Bare, E. Ann; Burley, James R., II
1987-01-01
An investigation was conducted in the Langley 16-Foot Transonic Tunnel to determine the effect of a boattail angle and wedge-size trade on the performance of nonaxisymmetric wedge nozzles installed on a generic twin-engine fighter aircraft model. Test data were obtained at static conditions and at Mach numbers from 0.60 to 1.25. Angle of attack was held constant at 0 deg. High-pressure air was used to simulate jet exhaust, and the nozzle pressure ratio was varied from 1.0 (jet off) to slightly over 15.0. For the configurations studied, the results indicate that wedge size can be reduced without affecting aeropropulsive performance.
Wind-tunnel free-flight investigation of a supersonic persistence fighter
NASA Technical Reports Server (NTRS)
Hahne, David E.; Wendel, Thomas R.; Boland, Joseph R.
1993-01-01
Wind-tunnel free-flight tests have been conducted in the Langley 30- by 60-Foot Wind Tunnel to examine the high-angle-of-attack stability and control characteristics and control law design of a supersonic persistence fighter (SSPF) at 1 g flight conditions. In addition to conventional control surfaces, the SSPF incorporated deflectable wingtips (tiperons) and pitch and yaw thrust vectoring. A direct eigenstructure assignment technique was used to design control laws to provide good flying characteristics well into the poststall angle-of-attack region. Free-flight tests indicated that it was possible to blend effectively conventional and unconventional control surfaces to achieve good flying characteristics well into the poststall angle-of-attack region.
Paterson, Kade L; Hinman, Rana S; Hunter, David J; Wrigley, Tim V; Bennell, Kim L
2015-07-01
To document the prevalence of foot pain and foot pain laterality in people with knee osteoarthritis (OA) and to examine its impact on health and function. Participants from the Progression subcohort (n = 1,255, ages 45-79 years) of the Osteoarthritis Initiative with symptomatic tibiofemoral knee OA were included. Prevalence of foot pain, defined as pain in the foot/ankle, and foot pain laterality were determined. Health status was evaluated using the Western Ontario and McMaster Universities Osteoarthritis Index, the Short Form-12 Health Survey, and the Center for Epidemiological Studies Depression Scale. Function was assessed using the 20-meter walk test (WT) and a repeated chair stand test. Differences in health and functional measures were compared between groups with and without foot pain using multivariate analysis of covariance. One-fourth (n = 317 [25%]) of people with knee OA experienced concurrent foot pain, with the majority (n = 174 [55%]) reporting pain in both feet. After adjusting for covariates, people with foot pain scored worse on all health measures and on the 20-meter WT, compared to those without (P < 0.05). Differences in health and function were found between the bilateral and ipsilateral foot pain groups compared to those without foot pain (P < 0.05), but no differences were found with the contralateral group. Foot pain is common in people with knee OA, and bilateral and ipsilateral foot pain adversely affect health and function, suggesting laterality is important. Further research is needed to establish the mechanism and interaction of pathology at these sites and to evaluate foot pain treatment in this population. © 2015, American College of Rheumatology.
Paterson, Kade L; Hinman, Rana S; Hunter, David J; Wrigley, Tim V; Bennell, Kim L
2015-01-01
Objective To document the prevalence of foot pain and foot pain laterality in people with knee osteoarthritis (OA), and to examine its impact on health and function. Methods Participants from the Progression subcohort (n=1255, aged 45-79 years) of the Osteoarthritis Initiative with symptomatic tibiofemoral knee OA were included. Prevalence of foot pain, defined as pain in the foot/ankle, and foot pain laterality was determined. Health status was evaluated using the Western Ontario and McMaster Universities Osteoarthritis Index, the Short Form-12 and the Centre for Epidemiological Studies Depression Scale. Function was assessed using the 20-meter walk test (20MWT) and a repeated chair stand test. Differences in health and functional measures were compared between groups with and without foot pain using multivariate analysis of covariance. Results One quarter (n=317, 25%) of people with knee OA experienced concurrent foot pain, with the majority (n=174, 55%) reporting pain in both feet. After adjusting for covariates, people with foot pain scored worse on all health measures and on the 20MWT compared to those without (p<0.05). Differences in health and function were found between the bilateral and ispilateral foot pain groups compared to those without foot pain (p<0.05), however no differences were found with the contralateral group. Conclusion Foot pain is common in people with knee OA, and bilateral and ipsilateral foot pain adversely affects health and function suggesting laterality is important. Further research is needed to establish the mechanism and interaction of pathology at these sites, and to evaluate foot pain treatment in this population. PMID:25581254
Aarts, Chris A M; Heesterbeek, Petra J C; Jaspers, Perry E M; Stegeman, Mark; Louwerens, Jan Willem K
2016-12-01
Debate exists regarding the effect of triple fusion on the development of osteoarthritis (OA) of the ankle joint. The midterm outcome after triple arthrodesis and the prevalence of OA following triple arthrodesis are reported in this study. The role of alignment in the development of OA was investigated. Seventy five patients (87 feet) were evaluated in 2003 and of these, 48 patients (55 feet) were available for second evaluation in 2008. X-rays of the ankles and feet were made prior to surgery, in 2003 and in 2008, and the level of osteoarthritis (OA) was graded with the Kellgren and Lawrence score. Of all postoperative X-rays, the AP and lateral talo first metatarsal angle X-rays were compared. Also, standardized digital photos were made to assess the geometry/alignment. The Foot Function Index (FFI) and the American Orthopaedic Foot and Ankle Society (AOFAS) hindfoot score were completed. In order to investigate the role of the underlying alignment on the aggravation of ankle osteoarthritis, patients were divided into a 'varus' and a 'valgus' group based on the indication for surgery. The outcome scores (AOFAS and FFI) after triple arthrodesis remained stable in the present 7.5-year follow-up study. An important increase of OA of the ankle was not established, 58% of the patients showed no aggravation, 31% one-grade and 2% two-grade increase of OA. A trend was found (P=.063) towards aggravation of OA of the ankle in patients of the varus group with the highest medial arches (persistent cavovarus deformity). This study reports minor, not statistically significant, changes of the ankle joint following triple arthrodesis after 7.5 years. Clinical outcome remained stable in time. Clinical relevance It seems that triple arthrodesis as such does not lead to major osteoarthritis of the ankle, given that adequate alignment of the hindfoot is achieved. Level II, retrospective study. Copyright © 2015 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.
Khan, Soobia Saad; Khan, Saad Jawaid; Usman, Juliana
2017-03-01
Toe-out/-in gait has been prescribed in reducing knee joint load to medial knee osteoarthritis patients. This study focused on the effects of toe-out/-in at different walking speeds on first peak knee adduction moment (fKAM), second peak KAM (sKAM), knee adduction angular impulse (KAAI), net mechanical work by lower limb as well as joint-level contribution to the total limb work during level walking. Gait analysis of 20 healthy young adults was done walking at pre-defined normal (1.18m/s), slow (0.85m/s) and fast (1.43m/s) walking speeds with straight-toe (natural), toe-out (15°>natural) and toe-in (15°
Klenow, Tyler D; Kahle, Jason T; Highsmith, M Jason
2016-10-01
The "dead spot" phenomenon in prosthetics is a disruption in forward progression observed in the rearfoot of passive prosthetic foot-ankle systems which results in a compensatory and inefficient gait pattern by amputees. A metric to quantify the dead spot as a kinetic event has not yet been introduced. The present study implements a three-part metric to evaluate the dead spot in terms of time, magnitude, and total area using center of pressure velocity and a novel threshold value calculation. The metrics are implemented for proof of efficacy using a convenient sample of four amputees (2 transtibial, 2 transfemoral) who walked in a 3D motion capture system with integrated force plates over five foot conditions. "Continuous-lever" feet designs showed the most favorable metric results between subjects (p<0.05) and in an ad hoc analysis compared to an ideal foot condition within subjects (p>0.05). Ten of 18 (55.6%) foot conditions found to be similar to the ideal were continuous-lever feet. Lack of significant similarity between the feet and ideal conditions (1 of 18, 5.6%) were found in transfemoral subjects. The metric calculations were able to show statistical difference among foot conditions between subjects. One foot (continuous-lever, glass composite) had no detectable dead spot in the transtibial subjects. The lack of significant findings in transfemoral subjects indicates a different coefficient in threshold calculations may be more appropriate for these subjects versus transtibial subjects. Further research with larger sample is needed to determine clinically significant findings among feet and between transtibial and transfemoral subjects. Published by Elsevier Ltd.
The diabetic foot risks profile in Selebi Phikwe Government Hospital, Botswana.
Tshitenge, Stephane; Ganiyu, Adewale; Mbuka, Deogratias; Shama, Joseph M
2014-10-17
The present study aimed: (1) to evaluate the proportion of each diabetic foot (DF) risk category, according to the International Working Group on the Diabetic Foot (IWGDF) consensus, in patients attending the diabetic clinic in Selebi Phikwe Government Hospital (SPGH) and (2) to examine some of the factors that may be associated with the progression to higher risk categories such as anthropometric measurements, blood pressure, glycosylated haemoglobin (HbA1c) and lipid profile. A retrospective, cross sectional chart review of patients who had attended the diabetic clinic in SPGH from January 2013 to December 2013 was performed. Patients were included if they had undergone a foot examination. Patients with amputation due to accident were excluded. The DF risk category was assessed by determining the proportion of patients in each of four risk categories, as described by the IWGDF consensus. The study encompassed 144 records from patients reviewed for foot examination from January to December 2013. Patients' ages were between 16 and 85 years, 46 (40%) were male and 98 (60%) were female. The majority (122, [85%]) of patients were in DF risk category 0, whilst a limited number of patients were classified in risk category 1 (10, [6.9%]), risk category 2 (7, [4.9%]) and risk category 3 (5, [3.5%]). Most of the patients had the type 2 diabetes mellitus (139, [97%; 95% CI 92% - 99%]). Patients' ages were associated with the progressively higher DF risk categories. The adjusted odd ratio was 1.1 (95% CI 1.03-1.14; p = 0.004). The present study revealed that about 15% of patients attending the SPGH diabetic clinic were categorised in higher risk groups for diabetic foot; patients' ages were linked to the higher DF risk categories.
Biomechanical response to ankle-foot orthosis stiffness during running.
Russell Esposito, Elizabeth; Choi, Harmony S; Owens, Johnny G; Blanck, Ryan V; Wilken, Jason M
2015-12-01
The Intrepid Dynamic Exoskeletal Orthosis (IDEO) is an ankle-foot orthosis developed to address the high rates of delayed amputation in the military. Its use has enabled many wounded Service Members to run again. During running, stiffness is thought to influence an orthosis' energy storage and return mechanical properties. This study examined the effect of orthosis stiffness on running biomechanics in patients with lower limb impairments who had undergone unilateral limb salvage. Ten patients with lower limb impairments underwent gait analysis at a self-selected running velocity. 1. Nominal (clinically-prescribed), 2. Stiff (20% stiffer than nominal), and 3. Compliant (20% less stiff than nominal) ankle-foot orthosis stiffnesses were tested. Ankle joint stiffness was greatest in the stiffest strut and lowest in the compliant strut, however ankle mechanical work remained unchanged. Speed, stride length, cycle time, joint angles, moments, powers, and ground reaction forces were not significantly different among stiffness conditions. Ankle joint kinematics and ankle, knee and hip kinetics were different between limbs. Ankle power, in particular, was lower in the injured limb. Ankle-foot orthosis stiffness affected ankle joint stiffness but did not influence other biomechanical parameters of running in individuals with unilateral limb salvage. Foot strike asymmetries may have influenced the kinetics of running. Therefore, a range of stiffness may be clinically appropriate when prescribing ankle-foot orthoses for active individuals with limb salvage. Published by Elsevier Ltd.
NASA Technical Reports Server (NTRS)
Graham, David
1948-01-01
This report contains the results of the wind tunnel investigation of the pressure distribution on the flying mock-up of the Consolidated Vultee XP-92 airplane. Data are presented for the pressure distribution over the wing, vertical tail and the fuselage, and for the pressure loss and rate of flow through the ducted fuselage. Data are also presented for the calibration of two airspeed indicators, and for the calibration of angle-of-attack and sideslip-angle indicator vanes.
NASA Technical Reports Server (NTRS)
Huffman, J. K.; Fox, C. H., Jr.; Johnston, P. J.
1977-01-01
A 1/10-scale model of a proposed hypersonic aircraft with an integrated scramjet was tested. The investigation took place over a Mach number range from 0.2 to 0.7 and an angle of attack range from 2 deg to approximately 17 deg at a sideslip angle of 0 deg. The primary configuration variables studied were engine location, internal engine geometry, and external engine geometry. The results are presented without analysis.
A static investigation of the thrust vectoring system of the F/A-18 high-alpha research vehicle
NASA Technical Reports Server (NTRS)
Mason, Mary L.; Capone, Francis J.; Asbury, Scott C.
1992-01-01
A static (wind-off) test was conducted in the static test facility of the Langley 16-foot Transonic Tunnel to evaluate the vectoring capability and isolated nozzle performance of the proposed thrust vectoring system of the F/A-18 high alpha research vehicle (HARV). The thrust vectoring system consisted of three asymmetrically spaced vanes installed externally on a single test nozzle. Two nozzle configurations were tested: A maximum afterburner-power nozzle and a military-power nozzle. Vane size and vane actuation geometry were investigated, and an extensive matrix of vane deflection angles was tested. The nozzle pressure ratios ranged from two to six. The results indicate that the three vane system can successfully generate multiaxis (pitch and yaw) thrust vectoring. However, large resultant vector angles incurred large thrust losses. Resultant vector angles were always lower than the vane deflection angles. The maximum thrust vectoring angles achieved for the military-power nozzle were larger than the angles achieved for the maximum afterburner-power nozzle.
Prospective Molecular Characterization of Burn Wound Colonization: Novel Tools and Analysis
2012-10-01
sequence analysis to identify the genetic characteristics that enable Staphylococcus aureus to progress from simple skin and soft tissue infections ...to sepsis and endocarditis . We are confident that this work will lead to significant advancements in wound care and healing and human microbiome...of diabetic foot ulcers become infected at some point, with 25% of the infected foot ulcers resulting in lower limb amputation, making wound
Oh, Annie; Pearce, Jacqueline W.; Gandolfi, Barbara; Creighton, Erica K.; Suedmeyer, William K.; Selig, Michael; Bosiack, Ann P.; Castaner, Leilani J.; Whiting, Rebecca E. H.; Belknap, Ellen B.; Lyons, Leslie A.; Aderdein, Danielle; Alves, Paulo C.; Barsh, Gregory S.; Beale, Holly C.; Boyko, Adam R.; Castelhano, Marta G.; Chan, Patricia; Ellinwood, N. Matthew; Garrick, Dorian J.; Helps, Christopher R.; Kaelin, Christopher B.; Leeb, Tosso; Lohi, Hannes; Longeri, Maria; Malik, Richard; Montague, Michael J.; Munday, John S.; Murphy, William J.; Pedersen, Niels C.; Rothschild, Max F.; Swanson, William F.; Terio, Karen A.; Todhunter, Rory J.; Warren, Wesley C.
2017-01-01
African black-footed cats (Felis nigripes) are endangered wild felids. One male and full-sibling female African black-footed cat developed vision deficits and mydriasis as early as 3 months of age. The diagnosis of early-onset progressive retinal atrophy (PRA) was supported by reduced direct and consensual pupillary light reflexes, phenotypic presence of retinal degeneration, and a non-recordable electroretinogram with negligible amplitudes in both eyes. Whole genome sequencing, conducted on two unaffected parents and one affected offspring was compared to a variant database from 51 domestic cats and a Pallas cat, revealed 50 candidate variants that segregated concordantly with the PRA phenotype. Testing in additional affected cats confirmed that cats homozygous for a 2 base pair (bp) deletion within IQ calmodulin-binding motif-containing protein-1 (IQCB1), the gene that encodes for nephrocystin-5 (NPHP5), had vision loss. The variant segregated concordantly in other related individuals within the pedigree supporting the identification of a recessively inherited early-onset feline PRA. Analysis of the black-footed cat studbook suggests additional captive cats are at risk. Genetic testing for IQCB1 and avoidance of matings between carriers should be added to the species survival plan for captive management. PMID:28322220
NASA Technical Reports Server (NTRS)
Cummings, J. W.; Foster, T. F.; Lockman, W. K.
1976-01-01
Data obtained from a heat transfer test conducted on an 0.006-scale space shuttle orbiter and external tank in the NASA-Ames Research Center 3.5-foot Hypersonic Wind Tunnel are presented. The purpose of this test was to obtain data under simulated return-to-launch-site abort conditions. Configurations tested were integrated orbiter and external tank, orbiter alone, and external tank alone at angles of attack of 0, + or - 30, + or - 60, + or - 90, and + or - 120 degrees. Runs were conducted at Mach numbers of 5.2 and 5.3 for Reynolds numbers of 1.0 and 4.0 million per foot, respectively. Heat transfer data were obtained from 75 orbiter and 75 external tank iron-constantan thermocouples.
NASA Technical Reports Server (NTRS)
Walstad, D. G.; Lockman, W. K.
1974-01-01
Data obtained from heat transfer tests of an 0.006-scale space shuttle vehicle in a 3.5-foot hypersonic wind tunnel are presented. The purpose of these tests was to parametrically investigate the ascent heating of the integrated vehicle. Configurations tested were complete for integrated vehicle, orbiter alone, external tank alone, and SRB alone. All configurations were tested with and without transition grit. Testing was conducted at a Mach number of 5.3, and at Reynolds numbers of 2 and 5 million per foot. The angle of attack range varied from 0 to minus 5 degress, execpt for SRB alone, which was tested from minus 5 to 90 degrees. Heat transfer data were obtained from 223 iron-constantan thermocouples attached to thin-skin stainless steel inserts.
NASA Technical Reports Server (NTRS)
Jacobs, P. F.
1985-01-01
An investigation was conducted in the Langley 8 Foot Transonic Pressure Tunnel to determine the effect of aileron deflections on the aerodynamic characteristics of a subsonic energy efficient transport (EET) model. The semispan model had an aspect ratio 10 supercritical wing and was configured with a conventionally located set of ailerons (i.e., a high speed aileron located inboard and a low speed aileron located outboard). Data for the model were taken over a Mach number range from 0.30 to 0.90 and an angle of attack range from approximately -2 deg to 10 deg. The Reynolds number was 2.5 million per foot for Mach number = 0.30 and 4 million per foot for the other Mach numbers. Model force and moment data, aileron effectiveness parameters, aileron hinge moment data, otherwise pressure distributions, and spanwise load data are presented.
Conservative management of pes valgus with plantar flexed talus, flexible.
Bleck, E E; Berzins, U J
1977-01-01
The type of flat foot that we have called pes valgus with plantar flexed talus, flexible, was treated in children with the Helfet heel seat or the UCBL shoe insert. In follow-up examination of 71 cases for periods longer than one year, 79 per cent of the patients showed that the UCBL shoe insert and the Helfet heel seat improved the clinical and roentgenographic appearance of the foot. The Helfet heel seat is recommended in cases where the plantar flexion angle of the talus is 35 to 45 degrees and the UCBL shoe insert in those cases of plantar flexion of the talus greater than 45 degrees.
Negative Thrust and Torque Characteristics of an Adjustable-Pitch Metal Propeller
NASA Technical Reports Server (NTRS)
Hartman, Edwin P
1934-01-01
This report presents the results of a series of negative thrust and torque measurements made with a 4 foot diameter model of a conventional aluminum-alloy propeller. The tests were made in the 20-foot propeller-research tunnel of the National Advisory Committee for Aeronautics. The results show that the negative thrust is considerably affected by the shape and size of the body behind the propeller, that the maximum negative thrust increases with decrease in blade-angle setting, and that the drag of a locked propeller may be greatly reduced by feathering it into the wind. Several examples of possible applications of the data are given.
NASA Technical Reports Server (NTRS)
Abeyounis, W. K.
1977-01-01
The phenomenon of separated flow on a series of circular-arc afterbodies was investigated using the Langley 16-foot transonic tunnel at free-stream Mach numbers from 0.40 to 0.95 at 0 deg angle of attack. Both high-pressure air and solid circular cylinders with a diameter equal to the nozzle exit diameter were used to simulate jet exhausts. A detailed data base of boundary layer separation locations was obtained using oil-flow techniques. The results indicate that boundary layer separation is most extensive on steep boattails at high Mach numbers.
NASA Technical Reports Server (NTRS)
Chee, E.
1975-01-01
Results of wind tunnel tests on a 0.030-scale model of the integrated space shuttle vehicle configuration 5 are presented. Testing was conducted in the NASA Ames Research Center 11 x 11 foot leg of the Unitary Plan Wind Tunnel to investigate pressure distributions for airloads analyses at Mach numbers from 0.9 through 1.4. Angles of attack and sideslip were varied from -6 to +6 degrees.
[Research progress of dipeptidyl peptidase 4 inhibitors on healing of chronic diabetic foot ulcers].
Gao, Yunyi; Liang, Yujie; Ran, Xingwu
2018-05-01
To review the effect of dipeptidyl peptidase 4 (DPP-4) inhibitors on the wound healing and its mechanisms in chronic diabetic foot ulcers. The latest literature concerning DPP-4 inhibitors for chronic diabetic foot ulcers was extensively reviewed, as well as the potential benefit and mechanism of DPP-4 inhibitors on wound healing of diabetic foot ulcers was analyzed thoroughly. DPP-4 inhibitors can accelerated the ulcer healing. The mechanisms probably include inhibiting the expression of the matrix metalloproteinase (MMP) and restoring the balance of the wound MMP and the tissue inhibitors of MMP; promoting recruitment of endothelial progenitor cells and augmenting angiogenesis; optimizing extracellular matrix construction and the immune response to persistent hypoxia in chronic diabetes wounds, and so on. At present, clinical researches show that DPP-4 inhibitors may be considered as an adjuvant treatment for chronic diabetic foot ulcers. DPP-4 inhibitors show promise in the local wound healing of chronic diabetic foot ulcers. However, more strictly designed, adequately powered, long-term follow-up, and high-quality randomized control trials are needed to further verify their efficacy and safety for chronic diabetic foot ulcers.
Mechanical and energetic consequences of rolling foot shape in human walking
Adamczyk, Peter G.; Kuo, Arthur D.
2013-01-01
SUMMARY During human walking, the center of pressure under the foot progresses forward smoothly during each step, creating a wheel-like motion between the leg and the ground. This rolling motion might appear to aid walking economy, but the mechanisms that may lead to such a benefit are unclear, as the leg is not literally a wheel. We propose that there is indeed a benefit, but less from rolling than from smoother transitions between pendulum-like stance legs. The velocity of the body center of mass (COM) must be redirected in that transition, and a longer foot reduces the work required for the redirection. Here we develop a dynamic walking model that predicts different effects from altering foot length as opposed to foot radius, and test it by attaching rigid, arc-like foot bottoms to humans walking with fixed ankles. The model suggests that smooth rolling is relatively insensitive to arc radius, whereas work for the step-to-step transition decreases approximately quadratically with foot length. We measured the separate effects of arc-foot length and radius on COM velocity fluctuations, work performed by the legs and metabolic cost. Experimental data (N=8) show that foot length indeed has much greater effect on both the mechanical work of the step-to-step transition (23% variation, P=0.04) and the overall energetic cost of walking (6%, P=0.03) than foot radius (no significant effect, P>0.05). We found the minimum metabolic energy cost for an arc foot length of approximately 29% of leg length, roughly comparable to human foot length. Our results suggest that the foot's apparently wheel-like action derives less benefit from rolling per se than from reduced work to redirect the body COM. PMID:23580717
Mechanical and energetic consequences of rolling foot shape in human walking.
Adamczyk, Peter G; Kuo, Arthur D
2013-07-15
During human walking, the center of pressure under the foot progresses forward smoothly during each step, creating a wheel-like motion between the leg and the ground. This rolling motion might appear to aid walking economy, but the mechanisms that may lead to such a benefit are unclear, as the leg is not literally a wheel. We propose that there is indeed a benefit, but less from rolling than from smoother transitions between pendulum-like stance legs. The velocity of the body center of mass (COM) must be redirected in that transition, and a longer foot reduces the work required for the redirection. Here we develop a dynamic walking model that predicts different effects from altering foot length as opposed to foot radius, and test it by attaching rigid, arc-like foot bottoms to humans walking with fixed ankles. The model suggests that smooth rolling is relatively insensitive to arc radius, whereas work for the step-to-step transition decreases approximately quadratically with foot length. We measured the separate effects of arc-foot length and radius on COM velocity fluctuations, work performed by the legs and metabolic cost. Experimental data (N=8) show that foot length indeed has much greater effect on both the mechanical work of the step-to-step transition (23% variation, P=0.04) and the overall energetic cost of walking (6%, P=0.03) than foot radius (no significant effect, P>0.05). We found the minimum metabolic energy cost for an arc foot length of approximately 29% of leg length, roughly comparable to human foot length. Our results suggest that the foot's apparently wheel-like action derives less benefit from rolling per se than from reduced work to redirect the body COM.
Increasing patient involvement in the diabetic foot pathway: a pilot randomized controlled trial.
McBride, E; Hacking, B; O'Carroll, R; Young, M; Jahr, J; Borthwick, C; Callander, A; Berrada, Z
2016-11-01
This pilot study aimed to explore whether the use of an intervention to increase shared decision-making (Decision Navigation) increased decision self-efficacy and foot-treatment adherence in patients with a diabetic foot ulcer. Fifty-six patients with a diabetic foot ulcer were randomized to receive Decision Navigation (N = 30) or usual care (N = 26). Primary outcomes included decision self-efficacy, adherence to foot treatment as reported by the participant and adherence to foot treatment as reported by the clinician. Secondary outcomes included foot ulcer healing rate, health-related quality of life, decision conflict and decision regret. Despite participants rating Decision Navigation as very helpful, mixed analyses of variance revealed no differences in decision self-efficacy or adherence between those receiving Decision Navigation and those receiving usual care. There were no differences between groups with regards to the secondary outcomes, with the exception of decision conflict which increased over time (12 weeks) for those receiving Decision Navigation. An intervention that facilitated patient involvement in treatment decisions did not have any impact on decisional confidence or adherence to foot treatment. This does not provide support for the suggestion that personalized care can improve health-related outcomes at this progressed stage of the patient's disease trajectory. We suggest that the diabetic foot population may benefit from interventions aimed at increasing motivation to engage with care pathways, centred on challenging personal controllability beliefs. © 2016 Diabetes UK.
Dayton, Paul; Feilmeier, Mindi; Hirschi, Jordan; Kauwe, Merrell; Kauwe, John S K
2014-01-01
We observed the changes in the angular measurements commonly used in the evaluation of the first metatarsal and first metatarsophalangeal joint in cadaveric specimens before and after frontal plane rotation of the first metatarsal. Measurements of the first and second intermetatarsal angle (IMA), hallux abductus angle, proximal articular set angle, and tibial sesamoid position (TSP) were taken after varying degrees of varus and valgus rotation of the first metatarsal. Standard dorsoplantar radiographs were taken at 0°, 10°, 20°, and 30° of valgus rotation of the first metatarsal and repeated at 10°, 20°, and 30° varus rotation of the first metatarsal. The data were analyzed using a mixed linear model to compare the change in each angle measurement over the range of valgus and varus rotation. The change in the TSP was significant in both valgus and varus rotations (p = .0004 and p = .028, respectively), an increase in valgus rotation causing an increase in the TSP and an increase in varus rotation causing a decrease in TSP. The change in the IMA was significant compared with valgus rotation (p = .028), showing that as the valgus rotation increased, the IMA also increased. However, compared with the varus rotation, the correlation was not significant (p = .18). The proximal articular set angle and hallux abductus angle measurements, compared with metatarsal rotation, showed positive trends but were not statistically significant. From our results and a review of the published data, we have hypothesized that frontal plane rotation of the first metatarsal is an integral component of hallux abducto valgus pathologic features, specifically in relation to the TSP and IMA. Copyright © 2014 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.
Hofstaetter, S G; Schuh, R; Trieb, K; Trnka, H J
2012-12-01
This prospective study examined the clinical and radiological results of the Chevron osteotomy with screw fixation and distal soft tissue release up to an intermetatarsal angle of 19°. Furthermore, the results are presented for patients over the age of 70 years, and whether or not there is a higher complication rate. 86 feet of patients between 23 and 81 years were included in the study. Apart from the overall group, a group with an intermetatarsal angle of 16° to 19° and a group of patients over 70 years old were eavaluated. They were evaluated preoperatively and at follow-up after an average of 3.3 years according to the American Orthopaedic Foot and Ankle Society score. The AOFAS score showed a significant improvement from 55 points preoperatively to 90 points at follow-up. The preoperative hallux valgus angle decreased significantly from 32° to 5° and the preoperative intermetatarsal angle decreased from 14° to 6°. Patient satisfaction in the overall group was rated in 92 % as excellent or good. Also, the patient group with 16° to 19° angles and the patients over 70 years showed a significant improvement of clinical and radiological parameters. The complication rate was very low in all groups. The results show that the Chevron osteotomy is a very good surgical technique with few complications for the correction of splay foot with hallux valgus deformity. We showed that by using the modified technique with a long plantar arm, an excessive soft tissue release and screw fixation, the indication can be extended up to an intermetatarsal angle of 19° when using screw fixation. Furthermore the patients over 70 years of age showed a significant improvement of clinical and radiological parameters without serious complications such as avascular necrosis or dislocation of the metatarsal head. Georg Thieme Verlag KG Stuttgart · New York.
Proceedings of the Black-footed Ferret & Prairie Dog Workshop, September 4-6, 1973
Linder, R.L.; Hillman, C.N.
1973-01-01
Both State and Federal agencies have been working with the black-footed ferret and prairie dog during the past few years. Much of the work is not extensive enough for publication in scientific journals and is, therefore, not reported. The objective of this Workshop was to bring workers together for discussion of the current status of the two species. Each of the Conservation Departments in the states and provinces within the former range of the prairie dog and the black-footed ferret was invited to participate. Federal agencies were also invited to report on current programs in progress on public lands.
NASA Technical Reports Server (NTRS)
Luidens, Roger W; Simon, Paul C
1950-01-01
Experimental investigation of flow about a slender body of revolution (NACA RM-10 missile) aligned and inclined to a supersonic stream was conducted at Mach numbers from 1.49 to 1.98 at a Reynolds number of approximately 30,000,000. Boundary-layer measurements at zero angle of attack are correlated with subsonic formulations for predicting boundary-layer thickness and profile. Comparison of pressure coefficients predicted by theory with experimental values showed close agreement at zero angle of attack and angle of attack except over the aft leeward side of body. At angle of attack, pitot pressure measurements in plane of model base indicated a pair of symmetrically disposed vortices on leeward side of body.
Functional Adaptation of the Calcaneus in Historical Foot Binding
Reznikov, Natalie; Phillips, Carina; Cooke, Martyn; Garbout, Amin; Ahmed, Farah
2017-01-01
ABSTRACT The normal structure of human feet is optimized for shock dampening during walking and running. Foot binding was a historical practice in China aimed at restricting the growth of female feet for aesthetic reasons. In a bound foot the shock‐dampening function normally facilitated by the foot arches is withdrawn, resulting in the foot functioning as a rigid extension of the lower leg. An interesting question inspiring this study regards the nature of adaptation of the heel bone to this nonphysiological function using the parameters of cancellous bone anisotropy and 3D fabric topology and a novel intertrabecular angle (ITA) analysis. We found that the trabecular microarchitecture of the normal heel bone, but not of the bound foot, adapts to function by increased anisotropy and preferred orientation of trabeculae. The anisotropic texture in the normal heel bone consistently follows the physiological stress trajectories. However, in the bound foot heel bone the characteristic anisotropy pattern fails to develop, reflecting the lack of a normal biomechanical input. Moreover, the basic topological blueprint of cancellous bone investigated by the ITA method is nearly invariant in both normal and bound foot. These findings suggest that the anisotropic cancellous bone texture is an acquired characteristic that reflects recurrent loading conditions; conversely, an inadequate biomechanical input precludes the formation of anisotropic texture. This opens a long‐sought‐after possibility to reconstruct bone function from its form. The conserved topological parameters characterize the generic 3D fabric of cancellous bone, which is to a large extent independent of its adaptation to recurrent loading and perhaps determines the mechanical competence of trabecular bone regardless of its functional adaptation. © 2017 The Authors. Journal of Bone and Mineral Research Published by Wiley Periodicals Inc. PMID:28561380
Restriction of foot supination by ankle braces in sudden fall situations.
Podzielny, S; Hennig, E M
1997-06-01
OBJECTIVE: To investigate the restriction of foot supination in different shoe orthotic combinations for unexpected ankle turns. DESIGN: A supination platform was used to experimentally induce sudden ankle turns. BACKGROUND: This study expanded on previous investigations of the effectiveness of different ankle braces and the influence of shoe material on foot supination. METHODS: For 21 male subjects pressure distribution data, achilles tendon angle, and supination velocity were collected. A comparison between a shoe with cut upper material and an intact shoe was done to show the influence of upper material on supination. The effectiveness of four different orthotics inside of an intact shoe were tested in comparison to the same shoe without ankle brace. Additionally, subjects rated their perceived supination movement of the foot. RESULTS: Between experimental conditions no large differences for the pressure distribution patterns were found. Three of the ankle braces reduced foot supination as well as supination velocities. More than two times lower supination values were measured for a footwear condition in which the upper material was cut away. Already during the free-fall most ankle braces caused a substantial reduction of foot inversion. CONCLUSION: The experiments demonstrated the influence of the upper material of a shoe and different orthotics on foot supination. Biomechanical measurements are necessary because of limited capabilities of subjects in detecting subtalar angular motions. RELEVANCE: This study investigated the effectiveness of different shoe conditions and ankle braces under experimental conditions that simulated unexpected ankle turns, the most frequent causes of sport injuries. The results of the study provide insights into which factors influence the amount of foot supination during unexpected ankle turns.
Functional Adaptation of the Calcaneus in Historical Foot Binding.
Reznikov, Natalie; Phillips, Carina; Cooke, Martyn; Garbout, Amin; Ahmed, Farah; Stevens, Molly M
2017-09-01
The normal structure of human feet is optimized for shock dampening during walking and running. Foot binding was a historical practice in China aimed at restricting the growth of female feet for aesthetic reasons. In a bound foot the shock-dampening function normally facilitated by the foot arches is withdrawn, resulting in the foot functioning as a rigid extension of the lower leg. An interesting question inspiring this study regards the nature of adaptation of the heel bone to this nonphysiological function using the parameters of cancellous bone anisotropy and 3D fabric topology and a novel intertrabecular angle (ITA) analysis. We found that the trabecular microarchitecture of the normal heel bone, but not of the bound foot, adapts to function by increased anisotropy and preferred orientation of trabeculae. The anisotropic texture in the normal heel bone consistently follows the physiological stress trajectories. However, in the bound foot heel bone the characteristic anisotropy pattern fails to develop, reflecting the lack of a normal biomechanical input. Moreover, the basic topological blueprint of cancellous bone investigated by the ITA method is nearly invariant in both normal and bound foot. These findings suggest that the anisotropic cancellous bone texture is an acquired characteristic that reflects recurrent loading conditions; conversely, an inadequate biomechanical input precludes the formation of anisotropic texture. This opens a long-sought-after possibility to reconstruct bone function from its form. The conserved topological parameters characterize the generic 3D fabric of cancellous bone, which is to a large extent independent of its adaptation to recurrent loading and perhaps determines the mechanical competence of trabecular bone regardless of its functional adaptation. © 2017 American Society for Bone and Mineral Research. © 2017 American Society for Bone and Mineral Research.
NASA Astrophysics Data System (ADS)
Pieczynska-Kozlowska, Joanna
2014-05-01
One of a geotechnical problem in the area of Wroclaw is an anthropogenic embankment layer delaying to the depth of 4-5m, arising as a result of historical incidents. In such a case an assumption of bearing capacity of strip footing might be difficult. The standard solution is to use a deep foundation or foundation soil replacement. However both methods generate significant costs. In the present paper the authors focused their attention on the influence of anthropogenic embankment variability on bearing capacity. Soil parameters were defined on the basis of CPT test and modeled as 2D anisotropic random fields and the assumption of bearing capacity were made according deterministic finite element methods. Many repeated of the different realizations of random fields lead to stable expected value of bearing capacity. The algorithm used to estimate the bearing capacity of strip footing was the random finite element method (e.g. [1]). In traditional approach of bearing capacity the formula proposed by [2] is taken into account. qf = c'Nc + qNq + 0.5γBN- γ (1) where: qf is the ultimate bearing stress, cis the cohesion, qis the overburden load due to foundation embedment, γ is the soil unit weight, Bis the footing width, and Nc, Nq and Nγ are the bearing capacity factors. The method of evaluation the bearing capacity of strip footing based on finite element method incorporate five parameters: Young's modulus (E), Poisson's ratio (ν), dilation angle (ψ), cohesion (c), and friction angle (φ). In the present study E, ν and ψ are held constant while c and φ are randomized. Although the Young's modulus does not affect the bearing capacity it governs the initial elastic response of the soil. Plastic stress redistribution is accomplished using a viscoplastic algorithm merge with an elastic perfectly plastic (Mohr - Coulomb) failure criterion. In this paper a typical finite element mesh was assumed with 8-node elements consist in 50 columns and 20 rows. Footings width B occupies 10 elements, 0.1 x 0.1 meter size. The footings are placed at the center of the mesh. Figure 1 shows the mesh used in probabilistic bearing capacity analysis. PIC Figure 1- Mesh used in analyses REFERENCES Fenton, G.A., Griffiths, D.V., (2008) Risk Assessment in Geotechnical Engineering, John Wiley & Sons, New York, Terzaghi, K. (1943). Theoretical Soil Mechanics, New York: John Wiley & Sons.
Mondal, Lakshmikanta; Baidya, Krishnapada; Choudhury, Himadri; Roy, Rupam
2013-06-01
The purpose of the study was to evaluate the progression of glaucomatous field damage in patients with stable primary open angle glaucoma after an attack of myocardial infarction. In this case control study, 62 open angle glaucoma patients were selected and regularly followed up. Among 62 patients, 9 had an attack of myocardial infarction. The intra-ocular pressure and visual field progression of both the groups (myocardial infarction versus no myocardial infarction) were analysed. Three (33.3%) out of 9 patients who had suffered from myocardial infarction showed progressive visual field loss whereas only 9 (16.9%) out of 53 patients who did not suffer from myocardial infarction, showed progressive field changes. Both the groups had stable target intra-ocular pressure between 14 and 16 mm Hg. Myocardial infarction may adversely influence the progression of primary open angle glaucoma which is suspected to result from ischaemia induced neuronal loss and only control of intraocular pressure is not the only solution. We have to look for other drugs that prevents ischaemia induced neuronal damage.
Inoue, Jun; Kawamura, Kazuya; Fujie, Masakatsu G
2012-01-01
In the present paper, we examine the appropriateness of a new model to examine the activity of the foot in gait. We developed an estimation model for foot-ankle muscular activity in the design of an ankle-foot orthosis by means of a statistical method. We chose three muscles for measuring muscular activity and built a Bayesian network model to confirm the appropriateness of the estimation model. We experimentally examined the normal gait of a non-disabled subject. We measured the muscular activity of the lower foot muscles using electromyography, the joint angles, and the pressure on each part of the sole. From these data, we obtained the causal relationship at every 10% level for these factors and built models for the stance phase, control term, and propulsive term. Our model has three advantages. First, it can express the influences that change during gait because we use 10% level nodes for each factor. Second, it can express the influences of factors that differ for low and high muscular-activity levels. Third, we created divided models that are able to reflect the actual features of gait. In evaluating the new model, we confirmed it is able to estimate all muscular activity level with an accuracy of over 90%.
Analysis of a kinetic multi-segment foot model. Part I: Model repeatability and kinematic validity.
Bruening, Dustin A; Cooney, Kevin M; Buczek, Frank L
2012-04-01
Kinematic multi-segment foot models are still evolving, but have seen increased use in clinical and research settings. The addition of kinetics may increase knowledge of foot and ankle function as well as influence multi-segment foot model evolution; however, previous kinetic models are too complex for clinical use. In this study we present a three-segment kinetic foot model and thorough evaluation of model performance during normal gait. In this first of two companion papers, model reference frames and joint centers are analyzed for repeatability, joint translations are measured, segment rigidity characterized, and sample joint angles presented. Within-tester and between-tester repeatability were first assessed using 10 healthy pediatric participants, while kinematic parameters were subsequently measured on 17 additional healthy pediatric participants. Repeatability errors were generally low for all sagittal plane measures as well as transverse plane Hindfoot and Forefoot segments (median<3°), while the least repeatable orientations were the Hindfoot coronal plane and Hallux transverse plane. Joint translations were generally less than 2mm in any one direction, while segment rigidity analysis suggested rigid body behavior for the Shank and Hindfoot, with the Forefoot violating the rigid body assumptions in terminal stance/pre-swing. Joint excursions were consistent with previously published studies. Copyright © 2012 Elsevier B.V. All rights reserved.
Variation in Foot Strike Patterns among Habitually Barefoot and Shod Runners in Kenya.
Lieberman, Daniel E; Castillo, Eric R; Otarola-Castillo, Erik; Sang, Meshack K; Sigei, Timothy K; Ojiambo, Robert; Okutoyi, Paul; Pitsiladis, Yannis
2015-01-01
Runners are often categorized as forefoot, midfoot or rearfoot strikers, but how much and why do individuals vary in foot strike patterns when running on level terrain? This study used general linear mixed-effects models to explore both intra- and inter-individual variations in foot strike pattern among 48 Kalenjin-speaking participants from Kenya who varied in age, sex, body mass, height, running history, and habitual use of footwear. High speed video was used to measure lower extremity kinematics at ground contact in the sagittal plane while participants ran down 13 meter-long tracks with three variables independently controlled: speed, track stiffness, and step frequency. 72% of the habitually barefoot and 32% of the habitually shod participants used multiple strike types, with significantly higher levels of foot strike variation among individuals who ran less frequently and who used lower step frequencies. There was no effect of sex, age, height or weight on foot strike angle, but individuals were more likely to midfoot or forefoot strike when they ran on a stiff surface, had a high preferred stride frequency, were habitually barefoot, and had more experience running. It is hypothesized that strike type variation during running, including a more frequent use of forefoot and midfoot strikes, used to be greater before the introduction of cushioned shoes and paved surfaces.
Liftoff and Transition Aerodynamics of the Ares I (A106) Launch Vehicle
NASA Technical Reports Server (NTRS)
Capone, Francis J.; Paulson, John W., Jr.; Erickson, Gary E.
2011-01-01
An investigation has been conducted in the NASA Langley Research Center 14- by 22- Foot Subsonic Wind Tunnel to obtain the liftoff and transition aerodynamics of the Ares I (A106) Crew Launch Vehicle. Data were obtained in free-air at angles of attack from 10 to 90 at various roll angles and at roll angles of 0 to 360 at various angles of attack. In addition, tower effects were assessed by testing with and without a mobile launcher/tower at all wind azimuth angles and at various model heights to simulate the rise of the vehicle as it clears the tower on launch. The free-air data will be used for low speed high angle of attack flight simulation and as a bridge to the low angle of attack ascent database (0.5 < Mach < 5.0) being developed with data from the Langley Unitary Plan Wind Tunnel and Boeing Polysonic Wind Tunnel. The Ares I Database Development Team will add incremental tower effects data to the free-air data to develop the database for tower clearance.
NASA Technical Reports Server (NTRS)
Erickson, Gary E.; Murri, Daniel G.
1993-01-01
Wind tunnel investigations have been conducted of forebody strakes for yaw control on 0.06-scale models of the F/A-18 aircraft at free-stream Mach numbers of 0.20 to 0.90. The testing was conducted in the 7- by 10-Foot Transonic Tunnel at the David Taylor Research Center and the Langley 7- by 10-Foot High-Speed Tunnel. The principal objectives of the testing were to determine the effects of the Mach number and the strake plan form on the strake yaw control effectiveness and the corresponding strake vortex induced flow field. The wind tunnel model configurations simulated an actuated conformal strake deployed for maximum yaw control at high angles of attack. The test data included six-component forces and moments on the complete model, surface static pressure distributions on the forebody and wing leading-edge extensions, and on-surface and off-surface flow visualizations. The results from these studies show that the strake produces large yaw control increments at high angles of attack that exceed the effect of conventional rudders at low angles of attack. The strake yaw control increments diminish with increasing Mach number but continue to exceed the effect of rudder deflection at angles of attack greater than 30 degrees. The character of the strake vortex induced flow field is similar at subsonic and transonic speeds. Cropping the strake planform to account for geometric and structural constraints on the F-18 aircraft has a small effect on the yaw control increments at subsonic speeds and no effect at transonic speeds.
Breiteneicher, Adam H; Norby, Bo; Schulz, Kurt S; Kerwin, Sharon C; Hulse, Don A; Fox, Derek B; Saunders, W Brian
2016-11-01
To determine the effect of sliding humeral osteotomy (SHO) on frontal plane thoracic limb alignment in standing and recumbent limb positions. Canine cadaveric study. Canine thoracic limbs (n=15 limb pairs). Limbs acquired from healthy Labrador Retrievers euthanatized for reasons unrelated to this study were mounted in a limb press and aligned in a standing position followed by axial loading at 30% body weight. Frontal plane radiography was performed in standing and recumbent positions pre- and post-SHO. In the standing position, lateralization of the foot was measured pre- and post-SHO using a textured grid secured to the limb press base plate. Twelve thoracic limb alignment values (mean ± SD and 95% CI) were determined using the center of rotation of angulation (CORA) method were compared using linear mixed models to determine if significant differences existed between limb alignment values pre- or post-SHO, controlling for dog, limb, and limb position. Six of 12 standing or recumbent alignment values were significantly different pre- and post-SHO. SHO resulted in decreased mechanical lateral distal humeral angle and movement of the mechanical humeral radio-ulnar angle, radio-ulnar metacarpal angle, thoracic humeral angle, and elbow mechanical axis deviation toward coaxial limb alignment. In the standing position, the foot underwent significant lateralization post-SHO. SHO resulted in significant alteration in frontal plane thoracic limb alignment. Additional studies are necessary to determine if the changes reported using our ex vivo model occur following SHO in vivo. © Copyright 2016 by The American College of Veterinary Surgeons.
Host microRNA-203a is antagonistic to the progression of foot-and-mouth disease virus infection
USDA-ARS?s Scientific Manuscript database
Sam68 was previously shown to be a critical host factor for foot-and-mouth disease virus (FMDV) replication. MicroRNA (miR)-203a is a potent regulator of Sam68 expression both in vitro and in vivo. Here, we showed transfection of miR-203a-3p and miR-203a-5p mimics separately and in combination in a ...
NASA Technical Reports Server (NTRS)
Pendergraft, O. C., Jr.
1979-01-01
Static pressure coefficient distributions on the forebody, afterbody, and nozzles of a 1/12 scale F-15 propulsion model were determined. The effects of nozzle power setting and horizontal tail deflection angle on the pressure coefficient distributions were investigated.
2012-05-11
Instructor Rob Mortin watches as Stennis Space Center firefighters Lt. Greg Lampley, Rodney Boone, Vance Forrest and Billy Scarborough practice high-angle rope rescue techniques during a May 11, 2012, training exercise. The exercise specifically focused on scenarios applicable to the 300-foot-tall, open-steel-structure A-3 Test Stand under construction at the rocket engine test facility.
NASA Technical Reports Server (NTRS)
Dye, W. H.; Lockman, W. K.
1975-01-01
The results of a hypersonic wind tunnel test program conducted using a 0.0175 scale thin-skin thermocouple model of the Space Shuttle Orbiter to obtain aerodynamic heat transfer data on the Orbiter under simulated reentry conditions were presented. The test program was conducted at a Mach number of 7.3 and a freestream Reynolds number ranging between 1.0 and 6.0 million/foot. The model was tested for angles of attack ranging between 10 deg and 30 deg and a sideslip angle of 0 deg. The model was constructed of 15-5 PH stainless steel with the instrumented areas machined to a nominal skin thickness of 0.030 in. The model instrumentation consisted of 288 iron-constantan thermocouples spot welded to the skin inner surface, but only 75 of these were used in this test program. A high-speed, analog-to-digital data acquisition system was used to record data on magnetic tape.
NASA Technical Reports Server (NTRS)
Hawthorne, P. J.
1976-01-01
Data obtained in wind tunnel tests are presented. The objectives of the tests were to: (1) obtain pressure distributions, forces and moments over the vehicle 5 Orbiter in the terminal area energy management (TAEM) and approach phases of flight; (2) obtain elevon and rudder hinge moments in the TAEM and approach phases of flight; (3) obtain body flap and elevon loads for verification of loads balancing with integrated pressure distributions; and (4) obtain pressure distributions near the short OMS pods in the high subsonic, transonic and low supersonic Mach number regimes. Testing was conducted over a Mach number range from 0.6 to 1.4 with Reynolds number variations from 4.57 million to 2.74 million per foot. Model angle-of-attack was varied from -4 to 16 degrees and angles of side slip ranged from -8 to 8 degrees.
NASA Technical Reports Server (NTRS)
Nichols, M. E.
1976-01-01
The results are documented of jet plume effects wind tunnel test of the 0.020-scale 88-OTS launch configuration space shuttle vehicle model in the 11 x 11 foot leg of the NASA/Ames Research Center Unitary Plan Wind Tunnel. This test involved cold gas main propulsion system (MPS) and solid rocket motor (SRB) plume simulations at Mach numbers from 0.6 to 1.4. Integrated vehicle surface pressure distributions, elevon and rudder hinge moments, and wing and vertical tail root bending and torsional moments due to MPS and SRB plume interactions were determined. Nozzle power conditions were controlled per pretest nozzle calibrations. Model angle of attack was varied from -4 deg to +4 deg; model angle of sideslip was varied from -4 deg to +4 deg. Reynolds number was varied for certain test conditions and configurations, with the nominal freestream total pressure being 14.69 psia. Plotted force and pressure data are presented.
NASA Technical Reports Server (NTRS)
Gillins, R. L.
1976-01-01
Results of tests conducted on a 0.0125-scale model of the Space Shuttle Orbiter and a 0.0125-scale model of the 747 CAM configuration in a 4 x 4-foot High Speed Wind Tunnel were presented. Force and moment data were obtained for each vehicle separately at a Mach number of 0.6 and for each vehicle in proximity to the other at Mach numbers of 0.3, 0.5, 0.6 and 0.7. The proximity effects of each vehicle on the other at separation distances (from the mated configuration) ranging from 1.5 feet to 75 feet were presented; 747 Carrier angles of attack from 0 deg to 6 deg and angles of sideslip of 0 deg and -5 deg were tested. Model variables included orbiter elevon, aileron and body flap deflections, orbiter tailcone on and off, and 747 stabilizer and rudder deflections.
NASA Technical Reports Server (NTRS)
Palazzo, Edward B.; Spearman, M. Leroy
1954-01-01
An investigation has been conducted in the Langley 4- by 4-foot supersonic pressure tunnel at a Mach number of 1.41 to determine the static stability and control and drag characteristics of a l/l5-scale model of the Grunman F9F-9 airplane. The effects of alternate fuselage shapes, wing camber, wing fences, and fuselage dive brakes on the aerodynamic characteristics were also investigated. These tests were made at a Reynolds number of 1.96 x l0 (exp 6) based on the wing mean aerodynamic chord of 0.545 foot. The basic configuration had a static margin of stability of 38.4 percent of the mean aerodynamic chord and a minimum drag coefficient of 0.049. For the maximum horizontal tail deflection investigated (-l0 deg), the maximum trim lift coefficient was 0.338. The basic configuration had positive static lateral stability at zero angle of attack and positive directional control throughout the angle-of-attack range investigated up to ll deg.
NASA Technical Reports Server (NTRS)
Johnson, J. D.; Braddock, W. F.
1974-01-01
Force tests of a 0.563 percent scale space shuttle solid rocket booster (SRB) model, MSFC Model 449, were conducted at the Marshall Space Flight Center 14 x 14 inch Trisonic Wind Tunnel. There were a total of 134 runs (pitch polars) made. Test Mach numbers were 0.6, 0.9, 1.2, 1.96, 2.74, 3.48, 4.00, 4.45, and 4.96; test angles of attack ranged from minus 10 degrees to 190 degrees; test Reynolds numbers ranged from 4.9 million per foot to 7.1 million per foot; and test roll angles were 0, 45, 90, and 135 degrees. The model was tested with three different engine nozzle/skirts. Two of these engine configurations differed from each other in the magnitude of the volume inside the nozzle and skirt. The third engine configuration had part of the nozzle removed. The model was tested with an electrical tunnel in combination with separation rockets of two different heights.
NASA Technical Reports Server (NTRS)
Carlson, John R.; Asbury, Scott C.
1994-01-01
An experimental investigation was performed in the Langley 16-Foot Transonic tunnel to determine the effects of external and internal flap rippling on the aerodynamics of a nonaxisymmetric nozzle. Data were obtained at several Mach numbers from static conditions to 1.2 over a range of nozzle pressure ratios. Nozzles with chordal boattail angles of 10, 20, and 30 degrees, with and without surface rippling, were tested. No effect on discharge coefficient due to surface rippling was observed. Internal thrust losses due to surface rippling were measured and attributed to a combination of additional internal skin friction and shock losses. External nozzle drag for the baseline configurations were generally less than that for the rippled configurations at all free-stream Mach numbers tested. The difference between the baseline and rippled nozzle drag levels generally increased with increasing boat tail angle. The thrust-minus-drag level for each rippled nozzle configuration was less than the equivalent baseline configuration for each Mach number at the design nozzle pressure ratio.
Internal performance of two nozzles utilizing gimbal concepts for thrust vectoring
NASA Technical Reports Server (NTRS)
Berrier, Bobby L.; Taylor, John G.
1990-01-01
The internal performance of an axisymmetric convergent-divergent nozzle and a nonaxisymmetric convergent-divergent nozzle, both of which utilized a gimbal type mechanism for thrust vectoring was evaluated in the Static Test Facility of the Langley 16-Foot Transonic Tunnel. The nonaxisymmetric nozzle used the gimbal concept for yaw thrust vectoring only; pitch thrust vectoring was accomplished by simultaneous deflection of the upper and lower divergent flaps. The model geometric parameters investigated were pitch vector angle for the axisymmetric nozzle and pitch vector angle, yaw vector angle, nozzle throat aspect ratio, and nozzle expansion ratio for the nonaxisymmetric nozzle. All tests were conducted with no external flow, and nozzle pressure ratio was varied from 2.0 to approximately 12.0.
NASA Technical Reports Server (NTRS)
Allen, E. C.
1972-01-01
Experimental aerodynamic investigations were conducted at the MSFC 14 x 14 inch trisonic wind tunnel on a .0044 scale model of the space shuttle orbiter, 110C. The test configurations included the orbiter alone and with external oxygen/hydrogen belly tanks. The six component aerodynamic force and moment data obtained cover a Mach number range from 0.6 to 4.96 at angles of attack from 10 to 60 deg at 0 deg sideslip angle and -10 to 10 deg at -6 deg sideslip angle. Reynolds number per unit length varied somewhat with Mach number but was a nominal 6.8 million per foot.
NASA Technical Reports Server (NTRS)
1977-01-01
Investigations are reported for the determination of aerodynamic effects of reducing the thickness of the reusable surface insulation located along the sides of the shuttle orbiter in order to allow weight reduction in the nose region. Six-component aerodynamic force and moment data were obtained at Mach numbers from 1.5 to 4.6 over an angle of attack range from about -1 deg to 28 deg. Additional tests were made over an angle of sideslip range from -6 deg to 6 deg at selected angles of attack. Test results are presented in graph and tables.
Annual changes in radiographic indices of the spine in cerebral palsy patients.
Lee, Seung Yeol; Chung, Chin Youb; Lee, Kyoung Min; Kwon, Soon-Sun; Cho, Kyu-Jung; Park, Moon Seok
2016-03-01
We estimated the annual changes in radiographic indices of the spine in cerebral palsy (CP) patients and analyzed the factors that influence its progression rate. We included CP patients who had undergone whole-spine radiography more than twice and were followed for at least 1 year. The scoliosis Cobb angle, coronal balance, apical vertebral translation, apical rotation, and pelvic obliquity were measured on anteroposterior (AP) radiographs; thoracic kyphosis and lumbar lordosis angles, and sagittal balance was measured on lateral radiographs; and migration percentage was measured on AP hip radiographs to determine hip instability. For each gross motor function classification system (GMFCS) level, the Cobb angles, apical vertebral translation, coronal and sagittal balance, and pelvic obliquity were adjusted by multiple factors with a linear mixed model. A total of 184 patients (774 radiographs) were included in this study. There was no significant annual change in scoliosis Cobb, thoracic kyphosis, and lumbar lordosis angles in the GMFCS level I-II and III groups. In the GMFCS level IV-V group, there was an annual increase of 3.4° in the scoliosis Cobb angle (p = 0.020). The thoracic kyphosis angle increased by 2.2° (p = 0.018) annually in the GMFCS level IV-V group. Apical vertebral translation increased by 5.4 mm (p = 0.029) annually in the GMFCS level IV-V group. Progression of coronal and sagittal balance and pelvic obliquity with aging were not statistically significant. Sex, hip instability, hip surgery, and triradiate cartilage did not affect the progression of scoliosis and the balance of the spine and pelvis. The scoliosis Cobb angle, thoracic kyphosis angle, and apical vertebral translation in the GMFCS level IV-V CP patients progressed with age. These findings can predict radiographic progression of scoliosis in CP patients.
Blue Origin Facility - Construction Progress
2017-03-21
Construction is progressing on Blue Origin's 750,000-square-foot facility being built at Exploration Park on NASA Kennedy Space Center property in Florida. Blue Origin will use the factory to manufacture its two-stage super-heavy-lift New Glenn launch vehicle and launch the vehicles from Space Launch Complex 46 at Cape Canaveral Air Force Station.
Fakoor, Mohammad; Sarafan, Naser; Mohammadhoseini, Payam; Khorami, Mohsen; Arti, Hamidreza; Mosavi, SeyedShahnam; Aghaeeaghdam, Amir
2014-01-01
Background: Hallux valgus deformity is a common chronic problem with a reported prevalence of 28.4% and its chief complaint is pain. Thus far, different surgical procedures with their proposed indications have been introduced. This study compared three current procedures, namely the chevron and scarf osteotomies and the McBride procedure. Methods: This retrospective cohort was conducted at the Ahvaz University of Medical Sciences on 44 patients with moderate hallux valgus deformity from 2010 and 2013. All of the patients underwent one of the three procedures (chevron, scarf or McBride). Preoperative and follow up radiographies were evaluated in terms of hallux valgus and intermetatarsal angle correction. The Foot and Ankle Disability Index was filled out to assess the functional outcome and the Visual Analogue Scale was used to evaluate pain. Also, satisfaction, aesthetics and the rate of recurrence was evaluated. Results: Hallux valgus angle and intermetatarsal angle correction were significantly higher in scarf, but not in chevron and McBride. However, from amongst the three procedures, there was no significant difference in terms of the Foot and Ankle Disability Index score, aesthetics, satisfaction level, pain score and recurrence rate. Conclusions: Considering that scarf osteotomy had better results in this study, we think that scarf osteotomy can be considered as a first choice for the treatment of moderate hallux valgus deformity. PMID:25207310
Fakoor, Mohammad; Sarafan, Naser; Mohammadhoseini, Payam; Khorami, Mohsen; Arti, Hamidreza; Mosavi, SeyedShahnam; Aghaeeaghdam, Amir
2014-03-01
Hallux valgus deformity is a common chronic problem with a reported prevalence of 28.4% and its chief complaint is pain. Thus far, different surgical procedures with their proposed indications have been introduced. This study compared three current procedures, namely the chevron and scarf osteotomies and the McBride procedure. This retrospective cohort was conducted at the Ahvaz University of Medical Sciences on 44 patients with moderate hallux valgus deformity from 2010 and 2013. All of the patients underwent one of the three procedures (chevron, scarf or McBride). Preoperative and follow up radiographies were evaluated in terms of hallux valgus and intermetatarsal angle correction. The Foot and Ankle Disability Index was filled out to assess the functional outcome and the Visual Analogue Scale was used to evaluate pain. Also, satisfaction, aesthetics and the rate of recurrence was evaluated. Hallux valgus angle and intermetatarsal angle correction were significantly higher in scarf, but not in chevron and McBride. However, from amongst the three procedures, there was no significant difference in terms of the Foot and Ankle Disability Index score, aesthetics, satisfaction level, pain score and recurrence rate. Considering that scarf osteotomy had better results in this study, we think that scarf osteotomy can be considered as a first choice for the treatment of moderate hallux valgus deformity.
NASA Technical Reports Server (NTRS)
Albertson, Cindy W.
1987-01-01
A model to be used in the flow studies and curved Thermal Protection System (TPS) evaluations was tested in the Langley 8 Foot High-Temperature Tunnel at a nominal Mach number of 6.8. The purpose of the study was to define the surface pressure and heating rates at high angles of attack (in support of curved metallic TPS studies) and to determine the conditions for which the model would be suitable as a test bed for aerothermal load studies. The present study was conducted at a nominal total temperature of 2400 and 3300 R, dynamic pressures from 2.3 to 10.9 psia, and free-stream Reynolds numbers from 4000,000 to 1,700,000/ft. The measurements consisted primarily of surface pressure and cold-wall (530 R) heating rates. Qualitative comparisons between predictions and data show that for this configuration, aerothermal tests should be limited to angles of attack between 10 and -10 degrees. Outside this range, the effects of free-stream flow nonuniformity appear in the data, as a result of the long length of the model. However, for TPS testing, this is not a concern and tests can be performed at angles of attack ranging from 20 to -20 degrees. Laminar and naturally turbulent boundary layers are available over limited ranges of conditions.
Bowerman, Erin; Whatman, Chris; Harris, Nigel; Bradshaw, Elizabeth; Karin, Janet
2014-11-01
To identify growth, maturation and biomechanical risk factors for overuse injury in elite adolescent ballet dancers. Maturation (Tanner scale), growth (foot length change) and age at onset of menarche were recorded in elite adolescent ballet dancers. A modified knee valgus angle and lateral tilt of the pelvis were measured using 2D video during two dance movements (fondu, temps levé) to quantify lower extremity alignment. Overuse dance injuries were recorded by a physiotherapist. The injury rate ratio (RR) associated with each variable was estimated using over-dispersed Poisson regression modelling. Changes in right foot length (RR = 1.41, CI = 0.93-2.13), right knee angles during the fondu (RR = 0.68, CI = 0.45-1.03) and temps levé (RR = 0.72, CI = 0.53-0.98), and pelvic angles during the temps levé on the left (RR = 0.52, CI = 0.30-0.90) and fondu on the right (RR = 1.28, CI = 0.91-1.80) were associated with substantial changes in injury risk. Rate of growth in elite adolescent ballet dancers is likely associated with an increase in risk of lower extremity overuse injury and better right lower extremity alignment is likely associated with a reduction in risk of right lower extremity overuse injury. Copyright © 2014 Elsevier Ltd. All rights reserved.
Collapsed heteroclinic snaking near a heteroclinic chain in dragged meniscus problems.
Tseluiko, D; Galvagno, M; Thiele, U
2014-04-01
A liquid film is studied that is deposited onto a flat plate that is inclined at a constant angle to the horizontal and is extracted from a liquid bath at a constant speed. We analyse steady-state solutions of a long-wave evolution equation for the film thickness. Using centre manifold theory, we first obtain an asymptotic expansion of solutions in the bath region. The presence of an additional temperature gradient along the plate that induces a Marangoni shear stress significantly changes these expansions and leads to the presence of logarithmic terms that are absent otherwise. Next, we numerically obtain steady solutions and analyse their behaviour as the plate velocity is changed. We observe that the bifurcation curve exhibits collapsed (or exponential) heteroclinic snaking when the plate inclination angle is above a certain critical value. Otherwise, the bifurcation curve is monotonic. The steady profiles along these curves are characterised by a foot-like structure that is formed close to the meniscus and is preceded by a thin precursor film further up the plate. The length of the foot increases along the bifurcation curve. Finally, we prove with a Shilnikov-type method that the snaking behaviour of the bifurcation curves is caused by the existence of an infinite number of heteroclinic orbits close to a heteroclinic chain that connects in an appropriate three-dimensional phase space the fixed point corresponding to the precursor film with the fixed point corresponding to the foot and then with the fixed point corresponding to the bath.
12 weeks of simulated barefoot running changes foot-strike patterns in female runners.
McCarthy, C; Fleming, N; Donne, B; Blanksby, B
2014-05-01
To investigate the effect of a transition program of simulated barefoot running (SBR) on running kinematics and foot-strike patterns, female recreational athletes (n=9, age 29 ± 3 yrs) without SBR experience gradually increased running distance in Vibram FiveFingers SBR footwear over 12 weeks. Matched controls (n=10, age 30 ± 4 yrs) continued running in standard footwear. A 3-D motion analysis of treadmill running at 12 km/h(-1) was performed by both groups, barefoot and shod, pre- and post-intervention. Post-intervention data indicated a more-forefoot strike pattern in the SBR group compared to controls; both running barefoot (P>0.05), and shod (P<0.001). When assessed barefoot, there were significant kinematic differences across time in the SBR group for ankle flexion angle at toe-off (P<0.01). When assessed shod, significant kinematic changes occurred across time, for ankle flexion angles at foot-strike (P<0.001) and toe-off (P<0.01), and for range of motion (ROM) in the absorptive phase of stance (P<0.01). A knee effect was recorded in the SBR group for flexion ROM in the absorptive phase of stance (P<0.05). No significant changes occurred in controls. Therefore, a 12-week transition program in SBR could assist athletes seeking a more-forefoot strike pattern and "barefoot" kinematics, regardless of preferred footwear. © Georg Thieme Verlag KG Stuttgart · New York.
Bent, Leah R.
2016-01-01
It has previously been shown that cutaneous sensory input from across a broad region of skin can influence proprioception at joints of the hand. The present experiment tested whether cutaneous input from different skin regions across the foot can influence proprioception at the ankle joint. The ability to passively match ankle joint position (17° and 7° plantar flexion and 7° dorsiflexion) was measured while cutaneous vibration was applied to the sole (heel, distal metatarsals) or dorsum of the target foot. Vibration was applied at two different frequencies to preferentially activate Meissner's corpuscles (45 Hz, 80 μm) or Pacinian corpuscles (255 Hz, 10 μm) at amplitudes ∼3 dB above mean perceptual thresholds. Results indicated that cutaneous input from all skin regions across the foot could influence joint-matching error and variability, although the strongest effects were observed with heel vibration. Furthermore, the influence of cutaneous input from each region was modulated by joint angle; in general, vibration had a limited effect on matching in dorsiflexion compared with matching in plantar flexion. Unlike previous results in the upper limb, we found no evidence that Pacinian input exerted a stronger influence on proprioception compared with Meissner input. Findings from this study suggest that fast-adapting cutaneous input from the foot modulates proprioception at the ankle joint in a passive joint-matching task. These results indicate that there is interplay between tactile and proprioceptive signals originating from the foot and ankle. PMID:26823342
Sawacha, Zimi; Guarneri, Gabriella; Cristoferi, Giuseppe; Guiotto, Annamaria; Avogaro, Angelo; Cobelli, Claudio
2012-05-01
The fundamental cause of lower-extremity complications in diabetes is chronic hyperglycemia leading to diabetic foot ulcer pathology. While the relationship between abnormal plantar pressure distribution and plantar ulcers has been widely investigated, little is known about the role of shear stress. Moreover, the mutual relationship among plantar pressure, shear stress, and abnormal kinematics in the etiology of diabetic foot has not been established. This lack of knowledge is determined by the lack of commercially available instruments which allow such a complex analysis. This study aims to develop a method for the simultaneous assessment of kinematics, kinetics, and plantar pressure on foot subareas of diabetic subjects by means of combining three commercial systems. Data were collected during gait on 24 patients (12 controls and 12 diabetic neuropathics) with a motion capture system synchronized with two force plates and two baropodometric systems. A four segment three-dimensional foot kinematics model was adopted for the subsegment angles estimation together with a three segment model for the plantar sub-area definition during gait. The neuropathic group exhibited significantly excessive plantar pressure, ground reaction forces on each direction, and a reduced loading surface on the midfoot subsegment (p<0.04). Furthermore the same subsegment displayed excessive dorsiflexion, external rotation, and eversion (p<0.05). Initial results showed that this methodology may enable a more appropriate characterization of patients at risk of foot ulcerations, and help planning prevention programs. Copyright © 2011 Elsevier B.V. All rights reserved.
Jowett, Charlie R J; Bedi, Harvinder S
Minimally invasive surgery is increasing in popularity. It is relevant in hallux valgus surgery owing to the potential for reduced disruption of the soft tissues and improved wound healing. We present our results and assess the learning curve of the minimally invasive Chevron Akin operation for hallux valgus. A total of 120 consecutive feet underwent minimally invasive Chevron Akin for symptomatic hallux valgus, of which 14 were excluded. They were followed up for a mean of 25 (range 18 to 38) months. The patients were clinically assessed using the American Orthopaedic Foot and Ankle Society score. Complications and patient satisfaction were recorded. The radiographs were analyzed and measurements recorded for hallux valgus and intermetatarsal angle correction. The mean age of the patients undergoing surgery was 55 (range 25 to 81) years. Of the 78 patients, 76 (97.4%) were female and 2 (2.6%) were male; 28 (35.9%) cases were bilateral. The mean American Orthopaedic Foot and Ankle Society score improved from 56 (range 23 to 76) preoperatively to 87 (range 50 to 100) postoperatively (p < .001). The mean hallux valgus and intermetatarsal angles preoperatively were 29.7° (range 12° to 46°) and 14.0° (range 8° to 20°). The corresponding postoperative angles were 10.3° (range 0° to 25°) and 7.6° (range 3° to 15°; p < .001). The patients were satisfied with the results of surgery in 87% of cases (92 of 106). The incidence of reoperation was 14% (15 of 106). These are the only reported results for this technique. They display a steep associated learning curve. However, the results are promising, and the learning curve is comparable to that for open hallux valgus surgery. Copyright © 2017 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.
Operative Treatment of Fifth Metatarsal Jones Fractures (Zones II and III) in the NBA.
O'Malley, Martin; DeSandis, Bridget; Allen, Answorth; Levitsky, Matthew; O'Malley, Quinn; Williams, Riley
2016-05-01
Proximal fractures of the fifth metatarsal (zone II and III) are common in the elite athlete and can be difficult to treat because of a tendency toward delayed union, nonunion, or refracture. The purpose of this case series was to report our experience in treating 10 NBA players, determine the healing rate, return to play, refracture rate, and role of foot type in these athletes. The records of 10 professional basketball players were retrospectively reviewed. Seven athletes underwent standard percutaneous internal fixation with bone marrow aspirate concentrate (BMAC) whereas the other 3 had open bone grafting primarily in addition to fixation and BMAC. Radiographic features evaluated included fourth-fifth intermetatarsal, fifth metatarsal lateral deviation, calcaneal pitch, and metatarsus adductus angles. Radiographic healing was observed at an overall average of 7.5 weeks and return to play was 9.8 weeks. Three athletes experienced refractures. There were no significant differences in clinical features or radiographic measurements except that the refracture group had the highest metatatarsus adductus angles. Most athletes were pes planus and 9 of 10 had a bony prominence under the fifth metatarsal styloid. This is the largest published series of operatively treated professional basketball players who exemplify a specific patient population at high risk for fifth metatarsal fracture. These players were large and possessed a unique foot type that seemed to be associated with increased risk of fifth metatarsal fracture and refracture. This foot type had forefoot metatarsus adductus and a fifth metatarsal that was curved with a prominent base. We continue to use standard internal fixation with bone marrow aspirate but advocate additional prophylactic open bone grafting in patients with high fourth-to-fifth intermetatarsal, fifth metatarsal lateral deviation, and metatarsus adductus angles as well as prominent fifth metatarsal styloids in order to improve fracture healing and potentially decrease the risk of refracture. Level IV, case series. © The Author(s) 2016.
Chang, Yunhee; Jeong, Bora; Kang, Sungjae; Ryu, Jeicheong; Kim, Gyoosuk
2017-01-01
The evaluation of multisegment coordination is important in gaining a better understanding of the gait and physical activities in humans. Therefore, this study aims to verify whether the use of knee sleeves affects the coordination of lower-limb segments during level walking and one-leg hopping. Eleven healthy male adults participated in this study. They were asked to walk 10 m on a level ground and perform one-leg hops with and without a knee sleeve. The segment angles and the response velocities of the thigh, shank, and foot were measured and calculated by using a motion analysis system. The phases between the segment angle and the velocity were then calculated. Moreover, the continuous relative phase (CRP) was calculated as the phase of the distal segment subtracted from the phase of the proximal segment and denoted as CRPTS (thigh–shank), CRPSF (shank–foot), and CRPTF (thigh–foot). The root mean square (RMS) values were used to evaluate the in-phase or out-of-phase states, while the standard deviation (SD) values were utilized to evaluate the variability in the stance and swing phases during level walking and in the preflight, flight, and landing phases during one-leg hopping. The walking velocity and the flight time improved when the knee sleeve was worn (p < 0.05). The segment angles of the thigh and shank also changed when the knee sleeve was worn during level walking and one-leg hopping. The RMS values of CRPTS and CRPSF in the stance phase and the RMS values of CRPSF in the preflight and landing phases changed (p < 0.05 in all cases). Moreover, the SD values of CRPTS in the landing phase and the SD values of CRPSF in the preflight and landing phases increased (p < 0.05 in all cases). These results indicated that wearing a knee sleeve caused changes in segment kinematics and coordination. PMID:28533981
Joint angles of the ankle, knee, and hip and loading conditions during split squats.
Schütz, Pascal; List, Renate; Zemp, Roland; Schellenberg, Florian; Taylor, William R; Lorenzetti, Silvio
2014-06-01
The aim of this study was to quantify how step length and the front tibia angle influence joint angles and loading conditions during the split squat exercise. Eleven subjects performed split squats with an additional load of 25% body weight applied using a barbell. Each subject's movements were recorded using a motion capture system, and the ground reaction force was measured under each foot. The joint angles and loading conditions were calculated using a cluster-based kinematic approach and inverse dynamics modeling respectively. Increases in the tibia angle resulted in a smaller range of motion (ROM) of the front knee and a larger ROM of the rear knee and hip. The external flexion moment in the front knee/hip and the external extension moment in the rear hip decreased as the tibia angle increased. The flexion moment in the rear knee increased as the tibia angle increased. The load distribution between the legs changed < 25% when split squat execution was varied. Our results describing the changes in joint angles and the resulting differences in the moments of the knee and hip will allow coaches and therapists to adapt the split squat exercise to the individual motion and load demands of athletes.
Foot segmental motion and coupling in stage II and III tibialis posterior tendon dysfunction.
Van de Velde, Maarten; Matricali, Giovanni Arnoldo; Wuite, Sander; Roels, Charlotte; Staes, Filip; Deschamps, Kevin
2017-06-01
Classification systems developed in the field of posterior tibialis tendon dysfunction omit to include dynamic measurements. Since this may negatively affect the selection of the most appropriate treatment modality, studies on foot kinematics are highly recommended. Previous research characterised the foot kinematics in patients with posterior tibialis tendon dysfunction. However, none of the studies analysed foot segmental motion synchrony during stance phase, nor compared the kinematic behaviour of the foot in presence of different posterior tibialis tendon dysfunction stages. Therefore, we aimed at comparing foot segmental motion and coupling in patients with posterior tibialis tendon dysfunction grade 2 and 3 to those of asymptomatic subjects. Foot segmental motion of 11 patients suffering from posterior tibialis tendon dysfunction stage 2, 4 patients with posterior tibialis tendon dysfunction stage 3 and 15 asymptomatic subjects was objectively quantified with the Rizzoli foot model using an instrumented walkway and a 3D passive motion capture system. Dependent variables were the range of motion occurring at the different inter-segment angles during subphases of stance and swing phase as well as the cross-correlation coefficient between a number of segments. Significant differences in range of motion were predominantly found during the forefoot push off phase and swing phase. In general, both patient cohorts demonstrated a reduced range of motion compared to the control group. This hypomobility occurred predominantly in the rearfoot and midfoot (p<0.01). Significant differences between both posterior tibialis tendon dysfunction patient cohorts were not revealed. Cross-correlation coefficients highlighted a loss of joint coupling between rearfoot and tibia as well as between rearfoot and forefoot in both posterior tibialis tendon dysfunction groups. The current evidence reveals considerable mechanical alterations in the foot which should be considered in the decision making process since it may help explaining the success and failure of certain conservative and surgical interventions. Copyright © 2017 Elsevier Ltd. All rights reserved.
Canine distemper in black-footed ferrets (Mustela nigripes) from Wyoming.
Williams, E S; Thorne, E T; Appel, M J; Belitsky, D W
1988-07-01
In September and October 1985, six black-footed ferrets (Mustela nigripes) were captured from the only known population, located near Meeteetse, Wyoming for captive propagation. Two days following capture an adult male showed signs of canine distemper and an adult female displayed similar signs 7 days postcapture; these infections were undoubtedly acquired prior to capture. Subsequently the four remaining captive black-footed ferrets also developed canine distemper and all eventually died. Clinical signs included severe pruritus, hyperkeratosis and progressive loss of body condition. A few animals had intermittent diarrhea and respiratory disease. Intranuclear and intracytoplasmic inclusion bodies were numerous in epithelial tissues and two black-footed ferrets had a mild to moderate meningoencephalitis. Canine distemper virus was isolated from four animals and paramyxovirus nucleocapsids were observed by electron microscopy of feces from all affected black-footed ferrets. Antibodies to canine distemper virus were not detected in sera of sick black-footed ferrets. Antibodies to canine distemper virus were found in sera of badgers (Taxidea taxus) and coyotes (Canis latrans) collected in the Meeteetse area in 1986. Most free-ranging black-footed ferrets in the colony apparently died of canine distemper during the summer and fall of 1985. An attempt was made to capture all surviving animals in the affected area in order to abort the epizootic and provide black-footed ferrets for captive propagation.
Sitoula, Prakash; Verma, Kushagra; Holmes, Laurens; Gabos, Peter G; Sanders, James O; Yorgova, Petya; Neiss, Geraldine; Rogers, Kenneth; Shah, Suken A
2015-07-01
Retrospective case series. This study aimed to validate the Sanders Skeletal Maturity Staging System and to assess its correlation to curve progression in idiopathic scoliosis. The Sanders Skeletal Maturity Staging System has been used to predict curve progression in idiopathic scoliosis. This study intended to validate that initial study with a larger sample size. We retrospectively reviewed 1100 consecutive patients with idiopathic scoliosis between 2005 and 2011. Girls aged 8 to 14 years (<2 yr postmenarche) and boys aged 10 to 16 years who had obtained at least 1 hand and spine radiograph on the same day for evaluation of skeletal age and scoliosis curve magnitude were followed to skeletal maturity (Risser stage 5 or fully capped Risser stage 4), curve progression to 50° or greater, or spinal fusion. Patients with nonidiopathic curves were excluded. There were 161 patients: 131 girls (12.3 ± 1.2 yr) and 30 boys (13.9 ± 1.1 yr). The distribution of patients within Sanders stage (SS) 1 through 7 was 7, 28, 41, 45, 7, 31, and 2 patients, respectively; modified Lenke curve types 1 to 6 were 26, 12, 63, 5, 38, and 17 patients, respectively. All patients in SS2 with initial Cobb angles of 25° or greater progressed, and patients in SS1 and SS3 with initial Cobb angles of 35° or greater progressed. Similarly, all patients with initial Cobb angles of 40° or greater progressed except those in SS7. Conversely, none of the patients with initial Cobb angles of 15° or less or those in SS5, SS6, and SS7 with initial Cobb angles of 30° or less progressed. Predictive progression of 67%, 50%, 43%, 27%, and 60% was observed for subgroups SS1/30°, SS2/20°, SS3/30°, SS4/30°, and SS6/35° respectively. This larger cohort shows a strong predictive correlation between SS and initial Cobb angle for probability of curve progression in idiopathic scoliosis. 3.
Pressure Available for Cooling with Cowling Flaps
NASA Technical Reports Server (NTRS)
Stickle, George W; Naiman, Irven; Crigler, John L
1941-01-01
Report presents the results of a full-scale investigation conducted in the NACA 20-foot tunnel to determine the pressure difference available for cooling with cowling flaps. The flaps were applied to an exit slot of smooth contour at 0 degree flap angle. Flap angles of 0 degree, 15 degrees, and 30 degrees were tested. Two propellers were used; propeller c which has conventional round blade shanks and propeller f which has airfoil sections extending closer to the hub. The pressure available for cooling is shown to be a direct function of the thrust disk-loading coefficient of the propeller.
NASA Technical Reports Server (NTRS)
Nussdorfer, Theodore J; Obery, Leonard J; Englert, Gerald W
1952-01-01
A study of a 20 degree and a 25 degree half-angle high mass-flow ratio conical supersonic inlet was made on a 16-inch ram jet in the 8- by 6-foot supersonic tunnel. A greater range of stable subcritical operation was obtained with the low mass-flow ratio inlets; a greater range was obtained with the 25 degree than with the 20 degree half-angle low mass-flow ratio inlet. The high mass-flow ratio inlet had the least drag.
NASA Technical Reports Server (NTRS)
Capone, Francis J.; Schirmer, Alberto W.
1993-01-01
An investigation was conducted at static conditions in order to determine the internal performance characteristics of a multiaxis thrust vectoring single expansion ramp nozzle. Yaw vectoring was achieved by deflecting yaw flaps in the nozzle sidewall into the nozzle exhaust flow. In order to eliminate any physical interference between the variable angle yaw flap deflected into the exhaust flow and the nozzle upper ramp and lower flap which were deflected for pitch vectoring, the downstream corners of both the nozzle ramp and lower flap were cut off to allow for up to 30 deg of yaw vectoring. The effects of nozzle upper ramp and lower flap cutout, yaw flap hinge line location and hinge inclination angle, sidewall containment, geometric pitch vector angle, and geometric yaw vector angle were studied. This investigation was conducted in the static-test facility of the Langley 16-Foot Transonic Tunnel at nozzle pressure ratios up to 8.0.
NASA Technical Reports Server (NTRS)
Esparza, V.
1976-01-01
Aerodynamic separation data obtained from a wind tunnel test of an 0.0125-scale SSV Orbiter model of a VC70-000002 Configuration and a 0.0125-scale 747 model was presented. Separation data was obtained at a Mach number of 0.6 and three incidence angles of 4, 6, and 8 degrees. The orbiter angle of attack was varied from 0 to 14 degrees. Longitudinal, lateral and normal separation increments were obtained for fixed 747 angles of attack of 0, 2, and 4 degrees while varying the orbiter angle of attack. Control surface settings on the 747 carrier included rudder deflections of 0 and 10 degrees and horizontal stabilizer deflections of -1 and +5 degrees.
NASA Technical Reports Server (NTRS)
Garrett, L. V.; Buchanan, T. D.; Fryberger, P. E.
1988-01-01
An updated Space Shuttle aerodynamic data base was obtained in Tunnel B for two phases of the Glide Return to Launch Site (GRTLS) abort maneuver. One-and-a-quarter percent scale models of the Space Shuttle Orbiter and External Tank were used to measure the effects of various combinations of Reaction Control System (RCS) jet thrusters at Mach number 6. The angle-of-attack range for the isolated orbiter was -10 to 15 deg at sideslip angles from -5 to 10 deg during Phase 1 of testing. The angle-of-attack range for the mated orbiter and external tank was -5 to 15 deg with sideslip angles of -2 to 5 deg during Phase 2. The test was conducted at a unit Reynolds number of 0.75 million per foot.
Foot volume estimates based on a geometric algorithm in comparison to water displacement.
Mayrovitz, H N; Sims, N; Litwin, B; Pfister, S
2005-03-01
Assessing lower extremity limb volume and its change during and after lymphedema therapy is important for determining treatment efficacy and documenting outcomes. Although leg volumes may be determined by tape measure and other methods, there is no metric method to routinely assess foot volumes. Exclusion of foot volumes can under- or overestimate therapeutic progress. Our aim was to develop and test a metric measurement procedure and algorithm for practicing therapists to use to estimate foot volumes. The method uses a caliper and ruler to measure foot dimensions at standardized locations and calculates foot volume (VM) by a mathematical algorithm. VM was compared to volumes measured by water displacement (Vw) in 30 subjects (60 feet) using regression analysis and limits of agreement (LOA). Vw and VM (mean +/- sd) were similar 857 +/- 150 ml vs. 859 +/- 154 ml, and were highly correlated VM = 1.00Vw + 1.67 ml, r = 0.965, p < 0.001. The LOA for absolute volume differences and percentages were respectively +/- 79.6 ml and +/- 9.28 %. These results indicate that this metric method can be a useful alternative to water displacement when foot volumes are needed, but the water displacement method is contraindicated, impractical to implement, too time consuming or is not available.
Investigation of very low blockage ratio boattail models in the Langley 16-foot transonic tunnel
NASA Technical Reports Server (NTRS)
Reubush, D. E.
1976-01-01
An investigation at an angle of attack of 0 deg was conducted in a 16 foot transonic tunnel at Mach numbers from 0.4 to 1.05 to determine the limits in Mach number at which valid boattail pressure drag data may be obtained with very low blockage ratio bodies. Extreme care was exercised when examining any data taken at subsonic Mach numbers very near 1.0 and lower than the supersonic Mach number at which shock reflections miss the model. Boattail pressure coefficient distributions did not indicate any error, but when integrated boattail pressure drag data was plotted as a function of Mach number, data which were in error were identified.
NASA Technical Reports Server (NTRS)
Robinson, Ross B.; Morris, Odell A.
1960-01-01
An investigation has been conducted in the Langley 4- by 4-foot supersonic pressure tunnel to determine the aerodynamic characteristics in pitch of a two-stage-rocket model configuration which simulated the last two stages of the launching vehicle for an inflatable sphere. Tests were made through an angle-of-attack range from -6 deg to 18 deg at dynamic pressures of 102 and 255 pounds per square foot with corresponding Mach numbers of 1.89 and 1.98 for the model both with and without a bumper arrangement designed to protect the rocket casing from the outer shell of the vehicle.
Subtasks affecting step-length asymmetry in post-stroke hemiparetic walking.
Kim, Woo-Sub
2016-10-01
This study was performed to investigate whether components from trunk progression (TP) and step length were related to step length asymmetry in walking in patients with hemiparesis. Gait analysis was performed for participants with hemiparesis and healthy controls. The distance between the pelvis and foot in the anterior-posterior axis was calculated at initial-contact. Step length was partitioned into anterior foot placement (AFP) and posterior foot placement (PFP). TP was partitioned into anterior trunk progression (ATP) and posterior trunk progression (PTP). The TP pattern and step length pattern were defined to represent intra-TP and intra-step spatial balance, respectively. Of 29 participants with hemiparesis, nine participants showed longer paretic step length, eight participants showed symmetric step length, and 12 participants showed shorter paretic step length. For the hemiparesis group, linear regression analysis showed that ATP asymmetry, AFP asymmetry, and TP patterns had significant predictability regarding step length asymmetry. Prolonged paretic ATP and shortened paretic AFP was the predominant pattern in the hemiparesis group, even in participants with symmetric step length. However, some participants showed same direction of ATP and AFP asymmetry. These findings indicate the following: (1) ATP asymmetries should be observed to determine individual characteristics of step length asymmetry, and (2) TP patterns can provide complementary information for non-paretic limb compensation. Copyright © 2016 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Aidi, Chafik; Klingelhoefer, F.; Yelles-Chaouche, A.; Beslier, M.; Bracene, R.; Philippe, S.; Djellit, H.; Galve, A.; Bounif, A.; Schenini, L.; Sage, F.; Charvis, P.
2013-12-01
During the Algerian-French SPIRAL cruise (Sismique Profonde et Investigation Régionale du Nord de l'Algérie) conducted onboard R/V Atalante (September-October 2009), one deep reflection and wide-angle seismic profile with total length of 140 km was acquired on the Algerian margin, offshore Greater Kabylia. 40 ocean bottom seismometers (OBS) were deployed on the profile, located perpendicular to the margin and it was additionally extended on land using 26 seismological stations. A 8350 in3 tuned air-gun array consisting of 10 Bolt air-guns was used to generate deep frequency shots to allow for a good penetration. A coincident multi-channel seismic profile was acquired using a 3040 in3 seismic source and a 4.5 km 360 channel digital seismic streamer. Underway geophysical measurements included gravimetric and magnetic data. The combined profile with a total length of about 260 km, crosses from north to south the Algero-Provençal basin, the central Algerian margin and onshore the crystalline basement of the Kabylides bloc up to the southward limit of the internal zones. We present results concerning the sedimentary and crustal structures in the study area using tomographic inversion, forward and gravimetric modelling. Modelling of the wide-angle and multi-channel seismic data reveals that the thickness of the sedimentary cover along the profile varies from several hundreds of metres onland in Tiziouzou basin (R. Bracéne 2001), to ~4 km at the foot of the margin and then decreasing northward to less than 3 km. The Messinian evaporitic units have been modelled by a high velocity layer, representing a velocity inversion with underlying pre-Messinian Miocene sedimentary layers. Progressive thinning of the continental crust towards the North is observed, with thicknesses decreasing from ~20 km at the foot of the margin to 4-5 km in the deep basin. Seismic velocities range between 6.2 and 6.6 km/s in the continental domain and 5.2 - 6.8 km/s in the deep basin. The uppermost crust of the deep margin is characterised by low velocities of only 4.5-5.0 km/s probably due to fracturing during the thinning of the crust. The transition between continental crust and crust of oceanic origin is located about 60 km from the coast. Its extension is very narrow (< 20 km) with a possibility of it being absent in this region. The crust underlying the basin at the foot of the continental slope is characterised by a thickness of only 3-5 km which is about 2 km thinner than normal oceanic crust. Seismic velocities however indicate that the crust is of oceanic origin and does not represent exhumed and partly serpentinised mantle material, although the presence of small amounts of mantle material in an otherwise igneous crust cannot be ruled out. Similar thin oceanic crust has been imaged in other Mediterranean Basins, such as the Liguro-Provençal basin (Gailler et al., 2009).
NASA Technical Reports Server (NTRS)
Gamble, J. D.
1975-01-01
A Langley-built 0.015-scale Space Shuttle Orbiter model with remote independently operated left and right elevon surfaces was tested. The objective of the test was to generate a detailed aerodynamic data base for the current shuttle orbiter configuration. Special attention was directed to definition of nonlinear aerodynamic characteristics by taking data at small increments in angle of attack, angle of sideslip, and elevon position. Six-component aerodynamic force and moment and elevon position data were recorded over an angle of attack range from -2 deg to 20 deg at angles of sideslip of 0 deg and plus or minus 2 deg. Additional tests were made over an angle of range from -6 deg to 8 deg at selected angles of attack. The test Mach numbers were 1.5 and 2.0 while the Reynolds number held at a constant two million per foot. Photographs of the test configuration are shown.
Noise of the SR-6 propeller model at 2 deg and 4 deg angles of attack
NASA Technical Reports Server (NTRS)
Dittmar, J. H.; Stefko, G. L.
1983-01-01
The noise generated by supersonic-tip-speed propellers creates a cabin noise problem for future airplanes powered by these propellers. Noise of a number of propeller models were measured in the NASA Lewis 8- by 6-Foot Wind Tunnel with flow parallel to the propeller axis. In flight, as a result of the induced upwash from the airplane wing, the propeller is at an angle of attack with respect to the incoming flow. Therefore, the 10-blade SR-6 propeller was operated at angle of attack to determine its noise behavior. Higher blade passage tones were observed for the propeller operating at angle of attack in a 0.6 axial Mach number flow. The noise increase was not symmetrical, with one wall of the wind tunnel showing a larger noise increase than the other wall. No noise increase was observed at angle of attack in a 0.8 axial Mach number flow. For this propeller the dominance of thickness noise, which does not increase with angle of attack, explains the lack of noise increase at the higher 0.8 Mach number.
Low Speed Analysis of Mission Adaptive Flaps on a High Speed Civil Transport Configuration
NASA Technical Reports Server (NTRS)
Lessard, Victor R.
1999-01-01
Thin-layer Navier-Stokes analyses were done on a high speed civil transport configuration with mission adaptive leading-edge flaps. The flow conditions simulated were Mach = 0.22 and Reynolds number of 4.27 million for angles-of-attack ranging from 0 to 18 degrees. Two turbulence closure models were used. Analyses were done exclusively with the Baldwin-Lomax turbulence model at low angle-of-attack conditions. At high angles-of-attack where considerable flow separation and vortices occurred the Spalart-Allmaras turbulence model was also considered. The effects of flow transition were studied. Predicted aerodynamic forces, moment, and pressure are compared to experimental data obtained in the 14- by 22-Foot Subsonic Tunnel at NASA Langley. The forces and moments correlated well with experimental data in terms of trends. Drag and pitching moment were consistently underpredicted. Predicted surface pressures compared well with experiment at low angles-of-attack. Above 10 angle-of-attack the pressure comparisons were not as favorable. The two turbulent models affected the pressures on the flap considerably and neither produced correct results at the high angles-of-attack.
Improvement of maneuver aerodynamics by spanwise blowing
NASA Technical Reports Server (NTRS)
Erickson, G. E.; Campbell, J. F.
1977-01-01
Spanwise blowing was used to test a generalized wind-tunnel model to investigate component concepts in order to provide improved maneuver characteristics for advanced fighter aircraft. Primary emphasis was placed on performance, stability, and control at high angles of attack and subsonic speeds. Test data were obtained in the Langley high speed 7 by 10 foot tunnel at free stream Mach numbers up to 0.50 for a range of model angles of attack, jet momentum coefficients, and leading and trailing edge flap deflection angles. Spanwise blowing on a 44 deg swept trapezoidal wing resulted in leading edge vortex enhancement with subsequent large vortex induced lift increments and drag polar improvements at the higher angles of attack. Small deflections of a leading edge flap delayed these lift and drag benefits to higher angles of attack. In addition, blowing was more effective at higher Mach numbers. Spanwise blowing in conjunction with a deflected trailing edge flap resulted in lift and drag benefits that exceeded the summation of the effects of each high lift device acting alone. Asymmetric blowing was an effective lateral control device at the higher angles of attack.
Investigation of a supersonic cruise fighter model flow field
NASA Technical Reports Server (NTRS)
Reubush, D. E.; Bare, E. A.
1985-01-01
An investigation was conducted in the Langley 16-Foot Transonic Tunnel to survey the flow field around a model of a supersonic cruise fighter configuration. Local values of angle of attack, side flow, Mach number, and total pressure ratio were measured with a single multi-holed probe in three survey areas on a model previously used for nacelle/nozzle integration investigations. The investigation was conducted at Mach numbers of 0.6, 0.9, and 1.2, and at angles of attack from 0 deg to 10 deg. The purpose of the investigation was to provide a base of experimental data with which theoretically determined data can be compared. To that end the data are presented in tables as well as graphically, and a complete description of the model geometry is included as fuselage cross sections and wing span stations. Measured local angles of attack were generally greater than free stream angle of attack above the wing and generally smaller below. There were large spanwise local angle-of-attack and side flow gradients above the wing at the higher free stream angles of attack.
Evaluating Problems With Footwear in the Geriatric Population.
Ikpeze, Tochukwu C; Omar, Adan; Elfar, John H
2015-12-01
Foot pathologies are common in nearly 80% of all elderly patients, and studies have indicated inappropriate footwear as one of the major underlying cause. It has been postulated that ill-fitting shoe wear affects plantar pressure, thus exacerbating weak balance. Complications arising from foot pathologies, which include difficulty in maintaining balance, have increased the risk of falls that can result in fractures and other serious injuries. The link between footwear and the onset or progression of certain foot pathologies has emphasized the need to explore and promote preventative measures to combat the issue. Wider and higher toe boxed shoes, along with sneakers, are examples of footwear documented to evenly distribute plantar pressure, increase comfort, and facilitate appropriate balance and gait. Ultimately, the use of appropriate footwear can help to better stabilize the foot, thus reducing the risk of sustaining debilitating physical injuries known to drastically decrease the quality of life among the geriatric population.
Macrodystrophia lipomatosa of foot involving great toe.
Gaur, A K; Mhambre, A S; Popalwar, H; Sharma, R
2014-06-01
Macrodystrophia lipomatosa is a rare form of congenital disorder in which there is localized gigantism characterized by progressive overgrowth of all mesenchymal elements with a disproportionate increase in the fibroadipose tissues. The adipose tissue infiltration involves subcutaneous tissue, periosteum, nerves and bone marrow. Most of the cases reported have hand or foot involvement. Patient seeks medical help for improving cosmesis or to get the size of the involved part reduced in order to reduce mechanical problems. We report a case of macrodystrophia lipomatosa involving medial side of foot with significant enlargement of great toe causing concern for cosmesis and inconvenience due to mechanical problems. The X-rays showed increased soft tissue with more of adipose tissue and increased size of involved digits with widening of ends. Since the patient's mother did not want any surgical intervention he was educated about foot care and proper footwear design was suggested. Copyright © 2014 Elsevier Ltd. All rights reserved.
Predictive Role of Preventive Measures in Preventing the Progression of Diabetic Foot
Zukic, Ejub; Gojak, Refet; Novakovic, Ana; Gazibera, Belma
2015-01-01
Introduction: Diabetes mellitus (DM) is one of the most common endocrine disease of modern life. Diabetic foot (DF) is the term for a foot of a patient suffering from DM with the potential risk of a number of pathological sequels, including infection, ulceration and/or destruction of deep tissue. Goal: To determine the importance of preventive measures to prevent the development of diabetic foot. Results: The gender structure of respondents categorized by the complication of DF (yes/no) was uniform. The average age was 60.15±12.2 years. Respondents without DF, 63% had 2 visits to the doctor a month, while in the group of those with DF, 39% of them had 3 visits to a doctor and 33% four or more times. Wearing comfortable shoes and foot hygiene in relation to the development of the DF are interdependent: c2=4,409; c2 = 12.47 (p <0.0005). Also, recurrent foot injury, and slow healing of sores in comparison to the development of the DF are mutually dependent; c2=13,195; c2=14 (p <0.0005). Conclusion: We found that there is a significant statistical relationship between preventive measures and development of the DF. PMID:26543412
Space Shuttle Pressure Data Model in the 10- by 10-Foot Supersonic Wind Tunnel
1978-04-21
Technicians examine a scale model of the space shuttle used to obtain pressure data during tests in the 10- by 10-Foot Supersonic Wind Tunnel at the National Aeronautics and Space Administration (NASA) Lewis Research Center. Lewis researchers used the 10- by 10 tunnel extensively in the 1970s to study shuttle configurations in order to forecast conditions during an actual flight. These tests included analysis of the solid rocket boosters’ aerodynamics, orbiter forebody angle -of -attack and air speed, base heating for entire shuttle, and engine-out loads. The test seen in this photograph used a 3.5- percent scale aluminum alloy model of the entire launch configuration. The program was designed to obtain aerodynamic pressure data. The tests were part of a larger program to study possible trouble areas for the shuttle’s new Advanced Flexible Reusable Surface Insulation. The researchers obtained aeroacoustic data and pressure distributions from five locations on the model. Over 100 high-temperature pressure transducers were attached to the model. Other portions of the test program were conducted at Lewis’ 8- by 6-Foot Supersonic Wind Tunnel and the 11- by 11-Foot Transonic Wind Tunnel at Ames Research Center.
Inter-segmental motions of the foot: differences between younger and older healthy adult females.
Lee, Dong Yeon; Seo, Sang Gyo; Kim, Eo Jin; Lee, Doo Jae; Bae, Kee Jeong; Lee, Kyoung Min; Choi, In Ho
2017-01-01
Although accumulative evidence exists that support the applicability of multi-segmental foot models (MFMs) in evaluating foot motion in various pathologic conditions, little is known of the effect of aging on inter-segmental foot motion. The objective of this study was to evaluate differences in inter-segmental motion of the foot between older and younger adult healthy females during gait using a MFM with 15-marker set. One hundred symptom-free females, who had no radiographic evidence of osteoarthritis, were evaluated using MFM with 15-marker set. They were divided into young ( n = 50, 20-35 years old) and old ( n = 50, 60-69 years old) groups. Coefficients of multiple correlations were evaluated to assess the similarity of kinematic curve. Inter-segmental angles (hindfoot, forefoot, and hallux) were calculated at each gait phase. To evaluate the effect of gait speed on intersegmental foot motion, subgroup analysis was performed according to the similar speed of walking. Kinematic curves showed good or excellent similarity in most parameters. Range of motion in the sagittal ( p < 0.001) and transverse ( p = 0.001) plane of the hallux, and sagittal ( p = 0.023) plane of the forefoot was lower in older females. The dorsiflexion ( p = 0.001) of the hallux at terminal stance and pre-swing phases was significantly lower in older females. When we compared young and older females with similar speed, these differences remained. Although the overall kinematic pattern was similar between young and older females, reduced range of inter-segmental motion was observed in the older group. Our results suggest that age-related changes need to be considered in studies evaluating inter-segmental motion of the foot.
Quantifying Dynamic Changes in Plantar Pressure Gradient in Diabetics with Peripheral Neuropathy.
Lung, Chi-Wen; Hsiao-Wecksler, Elizabeth T; Burns, Stephanie; Lin, Fang; Jan, Yih-Kuen
2016-01-01
Diabetic foot ulcers remain one of the most serious complications of diabetes. Peak plantar pressure (PPP) and peak pressure gradient (PPG) during walking have been shown to be associated with the development of diabetic foot ulcers. To gain further insight into the mechanical etiology of diabetic foot ulcers, examination of the pressure gradient angle (PGA) has been recently proposed. The PGA quantifies directional variation or orientation of the pressure gradient during walking and provides a measure of whether pressure gradient patterns are concentrated or dispersed along the plantar surface. We hypothesized that diabetics at risk of foot ulceration would have smaller PGA in key plantar regions, suggesting less movement of the pressure gradient over time. A total of 27 participants were studied, including 19 diabetics with peripheral neuropathy and 8 non-diabetic control subjects. A foot pressure measurement system was used to measure plantar pressures during walking. PPP, PPG, and PGA were calculated for four foot regions - first toe (T1), first metatarsal head (M1), second metatarsal head (M2), and heel (HL). Consistent with prior studies, PPP and PPG were significantly larger in the diabetic group compared with non-diabetic controls in the T1 and M1 regions, but not M2 or HL. For example, PPP was 165% (P = 0.02) and PPG was 214% (P < 0.001) larger in T1. PGA was found to be significantly smaller in the diabetic group in T1 (46%, P = 0.04), suggesting a more concentrated pressure gradient pattern under the toe. The proposed PGA may improve our understanding of the role of pressure gradient on the risk of diabetic foot ulcers.
Hagen, Marco; Asholt, Johannes; Lemke, Martin; Lahner, Matthias
2016-05-18
It is currently unclear how participation in different sports affects the angle-specific subtalar pronator and supinator muscle strength and pronator-to-supinator strength ratio (PSR). Based on the hypothesis that both differences sport-related patterns of play and foot-ground interaction may lead to sport-specific muscle adaptations, this study compared the angle specific pronator and supinator strength capacity of handball and soccer players. Eighteen healthy male handball and 19 soccer players performed maximum isometric voluntary isometric contractions using a custom-made testing apparatus. Peak pronator (PPT) and supinator torques (PST), pronator and supinator strength curves (normalised to the peak torque across all joint angles) and PSR were measured in five anatomical joint angles across the active subtalar range of motion (ROM). All analysed parameters were dependent on the subtalar joint angle. The ANOVA revealed significant `joint angle' × `group' interactions on PPT, pronator strength curves and PSR. No group differences were found for active subtalar ROM. In previously uninjured handball and soccer athletes, there were intrinsic differences in angle-specific subtalar pronator muscle strength. The lower PSR, which was found in the most supinated angle, can be seen as a risk factor for sustaining an ankle sprain.
Lamola, Giuseppe; Venturi, Martina; Martelli, Dario; Iacopi, Elisabetta; Fanciullacci, Chiara; Coppelli, Alberto; Rossi, Bruno; Piaggesi, Alberto; Chisari, Carmelo
2015-11-09
Forefoot ulcers (FU) are one of the most disabling and relevant chronic complications of diabetes mellitus (DM). In recent years there is emerging awareness that a better understanding of the biomechanical factors underlying the diabetic ulcer could lead to improve the management of the disease, with significant socio-economic impacts. Our purpose was to try to detect early biomechanical factors associated with disease progression. Thirty subjects (M/F: 22/8; mean age ± SD: 61,84 ± 10 years) with diagnosis of type II DM were included. The participants were divided into 3 groups (10 subjects per group) according to the stage of evolution of the disease: Group 1, subjects with newly diagnosed type II DM, without clinical or instrumental diabetic peripheral neuropathy (DPN) nor FU (group called "DM"); Group 2, with DPN but without FU (group called "DPN"); Group 3, with DPN and FU (group called "DNU"). All subjects underwent 3-D Gait Analysis during walking at self-selected speed, measuring spatio-temporal, kinematic and kinetic parameters and focusing on ankle and foot joints. The comparative analysis of values between groups was performed using 1-way ANOVA. We also investigated group to group differences with Tukey HSD test. The results taken into consideration were those with a significance of P < 0,05. 95 % confidence interval was also calculated. A progressive and significant trend of reduction of ROM in flexion-extension of the metatarso-phalangeal joint (P = 0.0038) and increasing of step width (P = 0.0265) with the advance of the disease was evident, with a statistically significant difference comparing subjects with recently diagnosed diabetes mellitus and subjects with diabetic neuropathy and foot ulcer (P = 0.0048 for ROM and P = 0.0248 for step width at Tukey's test). The results provide evidence that foot segmental kinematics, along with step width, can be proposed as simple and clear indicators of disease progression. This can be the starting point for planning more targeted strategies to prevent the occurrence and the recurrence of a FU in diabetic subjects.
Lee, Hong-Jae; Lim, Kil-Byung; Jung, Tae-Ho; Kim, Dug-Young
2013-01-01
Objective To compare the effect of foot orthotics and rehabilitation exercises by assessing balancing ability and joint proprioception in athletes who have chronic ankle instability. Methods Forty-one athletes who visited hospitals due to chronic ankle instability were randomly assigned to two groups. One group had ankle rehabilitation exercises while the other group had the same rehabilitation exercises as well as foot orthotics. Joint position sense of the ankle joint was examined by using an isokinetic exercise machine. Balancing abilities categorized into static, dynamic and functional balance abilities were evaluated by using computerized posturography. We tested the subjects before and after the four-week rehabilitation program. Results After the four-week treatment, for joint reposition sense evaluation, external 75% angle evaluation was done, revealing that the group with the application of foot orthotics improved by -1.07±1.64 on average, showing no significant difference between the two groups (p>0.05). Static, dynamic and functional balancing abilities using balance masters were evaluated, revealing that the two groups improved in some items, but showing no significant difference between them (p>0.05). Conclusion This study found that athletes with chronic ankle instability who had foot orthotics applied for four weeks improved their proprioceptive and balancing abilities, but did not show additional treatment effects compared with rehabilitation exercise treatment. PMID:24020033
Lee, Hong-Jae; Lim, Kil-Byung; Jung, Tae-Ho; Kim, Dug-Young; Park, Kyung-Rok
2013-08-01
To compare the effect of foot orthotics and rehabilitation exercises by assessing balancing ability and joint proprioception in athletes who have chronic ankle instability. Forty-one athletes who visited hospitals due to chronic ankle instability were randomly assigned to two groups. One group had ankle rehabilitation exercises while the other group had the same rehabilitation exercises as well as foot orthotics. Joint position sense of the ankle joint was examined by using an isokinetic exercise machine. Balancing abilities categorized into static, dynamic and functional balance abilities were evaluated by using computerized posturography. We tested the subjects before and after the four-week rehabilitation program. After the four-week treatment, for joint reposition sense evaluation, external 75% angle evaluation was done, revealing that the group with the application of foot orthotics improved by -1.07±1.64 on average, showing no significant difference between the two groups (p>0.05). Static, dynamic and functional balancing abilities using balance masters were evaluated, revealing that the two groups improved in some items, but showing no significant difference between them (p>0.05). This study found that athletes with chronic ankle instability who had foot orthotics applied for four weeks improved their proprioceptive and balancing abilities, but did not show additional treatment effects compared with rehabilitation exercise treatment.
Variation in Foot Strike Patterns among Habitually Barefoot and Shod Runners in Kenya
Lieberman, Daniel E.; Castillo, Eric R.; Otarola-Castillo, Erik; Sang, Meshack K.; Sigei, Timothy K.; Ojiambo, Robert; Okutoyi, Paul; Pitsiladis, Yannis
2015-01-01
Runners are often categorized as forefoot, midfoot or rearfoot strikers, but how much and why do individuals vary in foot strike patterns when running on level terrain? This study used general linear mixed-effects models to explore both intra- and inter-individual variations in foot strike pattern among 48 Kalenjin-speaking participants from Kenya who varied in age, sex, body mass, height, running history, and habitual use of footwear. High speed video was used to measure lower extremity kinematics at ground contact in the sagittal plane while participants ran down 13 meter-long tracks with three variables independently controlled: speed, track stiffness, and step frequency. 72% of the habitually barefoot and 32% of the habitually shod participants used multiple strike types, with significantly higher levels of foot strike variation among individuals who ran less frequently and who used lower step frequencies. There was no effect of sex, age, height or weight on foot strike angle, but individuals were more likely to midfoot or forefoot strike when they ran on a stiff surface, had a high preferred stride frequency, were habitually barefoot, and had more experience running. It is hypothesized that strike type variation during running, including a more frequent use of forefoot and midfoot strikes, used to be greater before the introduction of cushioned shoes and paved surfaces. PMID:26154285
The influence of arthritis on the anthropometric parameters of the feet of older women.
Castro, Alessandra Paiva; Rebelatto, José Rubens; Aurichio, Thaís Rabiatti; Greve, Patrícia
2010-01-01
Age-related and arthritis-related foot modifications have been described in literature, but there is a lack of references that allow shoes to be designed on the basis of specific anthropometric measurements of older women. The aim of this study was to identify the anthropometric characteristics of the feet of elderly women with and without arthritis. This is an observational transversal study. The right and left feet of 227 older women aged between 60 and 90 years (69.6 + or - 6.8 years) were evaluated, of whom 45 reported a diagnosis of arthritis (non-osteoarthritis). The anthropometric evaluation of the feet comprised the variables of width, perimeter, height, foot length, first and fifth metatarsophalangeal angles, the arch-index and the foot posture index (FPI). The data were analyzed using the analysis of probability to compare the groups (arthritic and non-arthritic women). The differences between the means were significant in the case of the FPI and some of its criteria, such as the calcaneal frontal plane position, the bulge in the region of the talo-navicular joint and the forefoot alignment. The width of the right foot was also significantly greater in the women with arthritis. These results are preliminary findings that may help direct larger studies of foot characteristics among older adults with arthritis. Copyright 2009 Elsevier Ireland Ltd. All rights reserved.
Hardin, E C; Su, A; van den Bogert, A J
2004-12-01
The purpose of this study was to determine how a driver's foot and ankle forces during a frontal vehicle collision depend on initial lower extremity posture and brake pedal force. A 2D musculoskeletal model with seven segments and six right-side muscle groups was used. A simulation of a three-second braking task found 3647 sets of muscle activation levels that resulted in stable braking postures with realistic pedal force. These activation patterns were then used in impact simulations where vehicle deceleration was applied and driver movements and foot and ankle forces were simulated. Peak rearfoot ground reaction force (F(RF)), peak Achilles tendon force (FAT), peak calcaneal force (F(CF)) and peak ankle joint force (F(AJ)) were calculated. Peak forces during the impact simulation were 476 +/- 687 N (F(RF)), 2934 +/- 944 N (F(CF)) and 2449 +/- 918 N (F(AJ)). Many simulations resulted in force levels that could cause fractures. Multivariate quadratic regression determined that the pre-impact brake pedal force (PF), knee angle (KA) and heel distance (HD) explained 72% of the variance in peak FRF, 62% in peak F(CF) and 73% in peak F(AJ). Foot and ankle forces during a collision depend on initial posture and pedal force. Braking postures with increased knee flexion, while keeping the seat position fixed, are associated with higher foot and ankle forces during a collision.
Allan, Richard; Woodburn, James; Telfer, Scott; Abbott, Mandy; Steultjens, Martijn Pm
2017-06-01
The knee adduction moment is consistently used as a surrogate measure of medial compartment loading. Foot orthoses are designed to reduce knee adduction moment via lateral wedging. The 'dose' of wedging required to optimally unload the affected compartment is unknown and variable between individuals. This study explores a personalised approach via three-dimensional printed foot orthotics to assess the biomechanical response when two design variables are altered: orthotic length and lateral wedging. Foot orthoses were created for 10 individuals with symptomatic medial knee osteoarthritis and 10 controls. Computer-aided design software was used to design four full and four three-quarter-length foot orthoses per participant each with lateral posting of 0° 'neutral', 5° rearfoot, 10° rearfoot and 5° forefoot/10° rearfoot. Three-dimensional printers were used to manufacture all foot orthoses. Three-dimensional gait analyses were performed and selected knee kinetics were analysed: first peak knee adduction moment, second peak knee adduction moment, first knee flexion moment and knee adduction moment impulse. Full-length foot orthoses provided greater reductions in first peak knee adduction moment (p = 0.038), second peak knee adduction moment (p = 0.018) and knee adduction moment impulse (p = 0.022) compared to three-quarter-length foot orthoses. Dose effect of lateral wedging was found for first peak knee adduction moment (p < 0.001), second peak knee adduction moment (p < 0.001) and knee adduction moment impulse (p < 0.001) indicating greater unloading for higher wedging angles. Significant interaction effects were found for foot orthosis length and participant group in second peak knee adduction moment (p = 0.028) and knee adduction moment impulse (p = 0.036). Significant interaction effects were found between orthotic length and wedging condition for second peak knee adduction moment (p = 0.002). No significant changes in first knee flexion moment were found. Individual heterogeneous responses to foot orthosis conditions were observed for first peak knee adduction moment, second peak knee adduction moment and knee adduction moment impulse. Biomechanical response is highly variable with personalised foot orthoses. Findings indicate that the tailoring of a personalised intervention could provide an additional benefit over standard interventions and that a three-dimensional printing approach to foot orthosis manufacturing is a viable alternative to the standard methods.
Effects of cruise engine location and power on interference
NASA Technical Reports Server (NTRS)
Bradley, D.
1972-01-01
Data are presented, in plotted form, of tests for determining the interference effects of space shuttle booster cruise engine location for power-on and power-off conditions. The tests were conducted in a 7 x 10 foot transonic wind tunnel; the model was a 0.015-scale space shuttle booster specially equipped for propulsion effects testing. Data were obtained over a Mach number range of 0.4 to 1.13 at angles of attack from -4 deg to 20 deg at zero degrees sideslip and at angles of sideslip from -6 deg to +6 deg at constant angles of attack of 0 deg, 6 deg, 15 deg, and in some cases 10 deg. Additional parameters investigated were: elevon deflection, canard deflection, aileron deflection, rudder deflection, canard position, and mass flow rate.
NASA Technical Reports Server (NTRS)
Capone, F. J.
1975-01-01
An investigation was conducted in the Langley 16-foot transonic tunnel to determine the induced lift characteristics of a vectored thrust concept in which a rectangular jet exhaust nozzle was located in the fuselage at the wing trailing edge. The effects of nozzle deflection angles of 0 deg to 45 deg were studied at Mach numbers from 0.4 to 1.2, at angles of attack up to 14 deg, and with thrust coefficients up to 0.35. Separate force balances were used to determine total aerodynamic and thrust forces as well as thrust forces which allowed a direct measurement of jet turning angle at forward speeds. Wing pressure loading and flow characteristics using oil flow techniques were also studied.
Inlet flow field investigation. Part 1: Transonic flow field survey
NASA Technical Reports Server (NTRS)
Yetter, J. A.; Salemann, V.; Sussman, M. B.
1984-01-01
A wind tunnel investigation was conducted to determine the local inlet flow field characteristics of an advanced tactical supersonic cruise airplane. A data base for the development and validation of analytical codes directed at the analysis of inlet flow fields for advanced supersonic airplanes was established. Testing was conducted at the NASA-Langley 16-foot Transonic Tunnel at freestream Mach numbers of 0.6 to 1.20 and angles of attack from 0.0 to 10.0 degrees. Inlet flow field surveys were made at locations representative of wing (upper and lower surface) and forebody mounted inlet concepts. Results are presented in the form of local inlet flow field angle of attack, sideflow angle, and Mach number contours. Wing surface pressure distributions supplement the flow field data.
NASA Technical Reports Server (NTRS)
Dods, J. B., Jr.; Hanly, R. D.; Efting, J. H.
1975-01-01
Shadowgraphs of five space shuttle launch configurations are presented. The model was a 4 percent-scale space shuttle vehicle, tested in the 11- by 11-foot Transonic Wind Tunnel at Ames Research Center. The Mach number was varied from 0.8 to 1.4 with three angles of sideslip (0 deg, 5 deg and -5 deg) that were used in conjunction with three angles of attack (4 deg, -4 deg, and 0 deg). The model configurations included both series-burn and parallel-burn configurations, two canopy configurations, two positions of the orbiter nose relative to the HO tank nose, and two HO tank nose-cones angles (15 deg and 20 deg). The data consist entirely of shadowgraph photographs.
NASA Technical Reports Server (NTRS)
Graham, L. A.; Jones, R. T.; Boltz, F. W.
1972-01-01
An experimental investigation was conducted in an 11- by 11-foot wind tunnel to determine the aerodynamic characteristics of an oblique high aspect ratio wing in combination with a high fineness-ratio Sears-Haack body. Longitudinal and lateral-directional stability data were obtained at wing yaw angles from 0 deg to 60 deg over a test Mach number range from 0.6 to 1.4 for angles of attack between minus 6 deg and 9 deg. The effects of changes in Reynolds number, dihedral, and trailing-edge angle were studied along with the effects of a roughness strip on the upper and lower surfaces of the wing. Flow-visualization studies were made to determine the nature of the flow on the wing surfaces.
Giandolini, Marlene; Gimenez, Philippe; Temesi, John; Arnal, Pierrick J.; Martin, Vincent; Rupp, Thomas; Morin, Jean-Benoit; Samozino, Pierre; Millet, Guillaume Y.
2016-01-01
Ultramarathon runners are exposed to a high number of impact shocks and to severe neuromuscular fatigue. Runners may manage mechanical stress and muscle fatigue by changing their running kinematics. Our purposes were to study (i) the effects of a 110-km mountain ultramarathon (MUM) on tibial shock acceleration and lower limb kinematics, and (ii) whether kinematic changes are modulated according to the severity of neuromuscular fatigue. Twenty-three runners participated in the study. Pre- and post-MUM, neuromuscular tests were performed to assess knee extensor (KE) and plantar flexor (PF) central and peripheral fatigue, and a treadmill running bouts was completed during which step frequency, peak acceleration, median frequency and impact frequency content were measured from tibial acceleration, as well as foot-to-treadmill, tibia-to-treadmill, and ankle flexion angles at initial contact, and ankle range of motion using video analysis. Large neuromuscular fatigue, including peripheral changes and deficits in voluntary activation, was observed in KE and PF. MVC decrements of ~35% for KE and of ~28% for PF were noted. Among biomechanical variables, step frequency increased by ~2.7% and the ankle range of motion decreased by ~4.1% post-MUM. Runners adopting a non rearfoot strike pre-MUM adopted a less plantarflexed foot strike pattern post-MUM while those adopting a rearfoot strike pre-MUM tended to adopt a less dorsiflexed foot strike pattern post-MUM. Positive correlations were observed between percent changes in peripheral PF fatigue and the ankle range of motion. Peripheral PF fatigue was also significantly correlated to both percent changes in step frequency and the ankle angle at contact. This study suggests that in a fatigued state, ultratrail runners use compensatory/protective adjustments leading to a flatter foot landing and this is done in a fatigue dose-dependent manner. This strategy may aim at minimizing the overall load applied to the musculoskeletal system, including impact shock and muscle stretch. PMID:27031830
NRL EIGHTH CARD Program Interim Progress Report, 1 March 1969 to 30 September 1969
1969-12-31
methods to measure the water vapor content of the atmosphere have been inves- tigated. One is based on the psychrometer method of measuring wet and dry bulb...over and under configuration. A shipboard psychrometer consisting of the sensors and blower and an 18.5-foot-high intake stack has been mounted on a...small boat. The intake stack may be partially dismounted to pro- vide a 9-foot intake level. The readout for the psychrometer is a multipoint Leeds and
Simulation of a slope adapting ankle prosthesis provided by semi-active damping.
LaPrè, Andrew K; Sup, Frank
2011-01-01
Modern passive prosthetic foot/ankles cannot adapt to variations in ground slope. The lack of active adaptation significantly compromises an amputee's balance and stability on uneven terrains. To address this deficit, this paper proposes an ankle prosthesis that uses semi-active damping as a mechanism to provide active slope adaptation. The conceptual ankle prosthesis consists of a modulated damper in series with a spring foot that allows the foot to conform to the angle of the surface in the sagittal plane. In support of this approach, biomechanics data is presented showing unilateral transtibial amputees stepping on a wedge with their daily-use passive prosthesis. Based on this data, a simulation of the ankle prosthesis with semi-active damping is developed. The model shows the kinematic adaptation of the prosthesis to sudden changes in ground slope. The results show the potential of an ankle prosthesis with semi-active damping to actively adapt to the ground slope at each step.
Minimally Invasive and Open Distal Chevron Osteotomy for Mild to Moderate Hallux Valgus.
Brogan, Kit; Lindisfarne, Edward; Akehurst, Harold; Farook, Usama; Shrier, Will; Palmer, Simon
2016-11-01
Minimally invasive surgical (MIS) techniques are increasingly being used in foot and ankle surgery but it is important that they are adopted only once they have been shown to be equivalent or superior to open techniques. We believe that the main advantages of MIS are found in the early postoperative period, but in order to adopt it as a technique longer-term studies are required. The aim of this study was to compare the 2-year outcomes of a third-generation MIS distal chevron osteotomy with a comparable traditional open distal chevron osteotomy for mild-moderate hallux valgus. Our null hypothesis was that the 2 techniques would yield equivalent clinical and radiographic results at 2 years. This was a retrospective cohort study. Eighty-one consecutive feet (49 MIS and 32 open distal chevron osteotomies) were followed up for a minimum 24 months (range 24-58). All patients were clinically assessed using the Manchester-Oxford Foot Questionnaire. Radiographic measures included hallux valgus angle, the intermetatarsal angle, hallux interphalangeal angle, metatarsal phalangeal joint angle, distal metatarsal articular angle, tibial sesamoid position, shape of the first metatarsal head, and plantar offset. Statistical analysis was done using Student t test or Wilcoxon rank-sum test for continuous data and Pearson chi-square test for categorical data. Clinical and radiologic postoperative scores in all domains were substantially improved in both groups (P < .001), but there was no statistically significant difference in improvement of any domain between open and MIS groups (P > .05). There were no significant differences in complications between the 2 groups ( > .5). The midterm results of this third-generation technique show that it was a safe procedure with good clinical outcomes and comparable to traditional open techniques for symptomatic mild-moderate hallux valgus. Level III, retrospective comparative study. © The Author(s) 2016.
The Lower Extremity Biomechanics of Single- and Double-Leg Stop-Jump Tasks
2011-01-01
The anterior cruciate ligament (ACL) injury is a common occurrence in sports requiring stop-jump tasks. Single- and double-leg stop-jump techniques are frequently executed in sports. The higher risk of ACL injury in single-leg drop landing task compared to a double-leg drop landing task has been identified. However the injury bias between single- and double-leg landing techniques has not been investigated for stop-jump tasks. The purpose of this study was to determine the differences between single- and double-leg stop-jump tasks in knee kinetics that were influenced by the lower extremity kinematics during the landing phase. Ground reaction force, lower extremity kinematics, and knee kinetics data during the landing phase were obtained from 10 subjects performing single- and double-leg stop-jump tasks, using motion-capture system and force palates. Greater peak posterior and vertical ground reaction forces, and peak proximal tibia anterior and lateral shear forces (p < 0.05) during landing phase were observed of single-leg stop-jump. Single-leg stop-jump exhibited smaller hip and knee flexion angle, and knee flexion angular velocity at initial foot contact with the ground (p < 0.05). We found smaller peak hip and knee flexion angles (p < 0.05) during the landing phase of single-leg stop-jump. These results indicate that single-leg landing may have higher ACL injury risk than double-leg landing in stop-jump tasks that may be influenced by the lower extremity kinematics during the landing phase. Key points Non-contact ACL injuries are more likely to occur during the single-leg stop-jump task than during the double-leg stop-jump task. Single-leg stop-jump exhibited greater peak proximal tibia anterior and lateral shear forces, and peak posterior and vertical ground reaction forces during the landing phase than the double-leg stop-jump task. Single-leg stop-jump exhibited smaller hip flexion angle, knee flexion angle, and knee flexion angular velocity at initial foot contact with the ground. Single-leg stop-jump exhibited greater peak knee extension and valgus moment during the landing phase than the double-leg stop-jump task. Single-leg stop-jump extended the hip joint at initial foot contact with the ground. PMID:24149308
The Physics of Toppling and Regaining Balance during a Pirouette.
Lott, Melanie B; Laws, Kenneth L
2012-12-01
One of the most common movements in dance is a turn around a vertical axis with one supporting foot on the floor--a pirouette. If the pirouette is not performed with the body on balance, it is not considered successful. Dancers are often taught to perform successful pirouettes by beginning the movement on balance and then keeping the body in that configuration, as opposed to correcting for an imbalance with small adjustments during the turn. Many, even advanced, dancers have significant difficulty performing more than two or three turns in a pirouette before losing balance, despite continued trial and error efforts to improve. To describe the mechanics of toppling and control of toppling during a pirouette, a theoretical model of a dancer in standard pirouette position was created, and an experimental study of real dancers performing pirouettes was conducted. Body segment parameters for the model (mass, length, etc.) were based on anatomical data and adjusted for sex, total body mass, and height. The principal moments of inertia were determined for several hypothetical dancers, and rigid body equations of motion numerically solved to express topple angle vs. time. When dancers reach too large a topple angle, they are forced to compensate by either hopping on the supporting foot in an attempt to regain balance or terminating the turn. The angle at which dancers lose stability and feel inclined to hop (θmax) was determined experimentally through a video analysis of nine intermediate to advanced ballet dancers' pirouettes (8 female, 1 male; 16 ± 2.3 years of age). The dancers hopped on the supporting foot after the body reached an average angle of 9.3 ± 1.9° from the vertical. With an average spin rate of 1.7 rev/s, it was found that a "rigid body" dancer (male or female) would need to begin the pirouette displaced less than one degree from the vertical in order to perform more than a double pirouette before reaching θmax. The results of this study demonstrate the difficulty of achieving many rotations when the body is held rigidly, whereas dancers may have success in consistently performing more pirouettes if they are taught strategies for regaining balance while turning.
Effect of Infrared Radiation on the Healing of Diabetic Foot Ulcer
Hakim, Ashrafalsadat; Sadeghi Moghadam, Ali; Shariati, Abdalali; karimi, Hamid; Haghighizadeh, Mohamad Hossien
2016-01-01
Background Diabetic foot ulcer is a worldwide health care concern affecting tens of thousands of patients. If these ulcers left untreated, they can create severe complications. Objectives This study was designed to examine the effect of infrared radiation on the healing of diabetic foot ulcer. Patients and Methods This clinical trial was performed on 50 patients referred to Dr. Ganjavian hospital in Dezful city, Iran, with diabetic foot ulcer degree 1 and 2 (based on Wegener Scale). Sample size was determined based on relevant studies of the recent decade. Patients were classified into the intervention and control groups (n = 25 in each group) in terms of age, gender, degree of ulcer, ulcer site and body mass index. In this study, work progress was evaluated according to the checklist of diabetic foot ulcer healing evaluation. Results The results of the current study showed that there was a statistically significant difference in healing ulcers (P < 0.05) and mean healing time (P < 0.05) between the two groups. Conclusions Using the infrared plus routine dressing is more effective than using merely routine dressing. PMID:27942260
Nephrin is necessary for podocyte recovery following injury in an adult mature glomerulus.
Verma, Rakesh; Venkatareddy, Madhusudan; Kalinowski, Anne; Li, Theodore; Kukla, Joanna; Mollin, Ashomathi; Cara-Fuentes, Gabriel; Patel, Sanjeevkumar R; Garg, Puneet
2018-01-01
Nephrin (Nphs1) is an adhesion protein that is expressed at the podocyte intercellular junction in the glomerulus. Nphs1 mutations in humans or deletion in animal genetic models results in a developmental failure of foot process formation. A number of studies have shown decrease in expression of nephrin in various proteinuric kidney diseases as well as in animal models of glomerular disease. Decrease in nephrin expression has been suggested to precede podocyte loss and linked to the progression of kidney disease. Whether the decrease in expression of nephrin is related to loss of podocytes or lead to podocyte detachment is unclear. To answer this central question we generated an inducible model of nephrin deletion (Nphs1Tam-Cre) in order to lower nephrin expression in healthy adult mice. Following tamoxifen-induction there was a 75% decrease in nephrin expression by 14 days. The Nphs1Tam-Cre mice had normal foot process ultrastructure and intact filtration barriers up to 4-6 weeks post-induction. Despite the loss of nephrin expression, the podocyte number and density remained unchanged during the initial period. Unexpectedly, nephrin expression, albeit at low levels persisted at the slit diaphragm up to 16-20 weeks post-tamoxifen induction. The mice became progressively proteinuric with glomerular hypertrophy and scarring reminiscent of focal and segmental glomerulosclerosis at 20 weeks. Four week-old Nphs1 knockout mice subjected to protamine sulfate model of podocyte injury demonstrated failure to recover from foot process effacement following heparin sulfate. Similarly, Nphs1 knockout mice failed to recover following nephrotoxic serum (NTS) with persistence of proteinuria and foot process effacement. Our results suggest that as in development, nephrin is necessary for maintenance of a healthy glomerular filter. In contrast to the developmental phenotype, lowering nephrin expression in a mature glomerulus resulted in a slowly progressive disease that histologically resembles FSGS a disease linked closely with podocyte depletion. Podocytes with low levels of nephrin expression are both susceptible and unable to recover following perturbation. Our results suggest that decreased nephrin expression independent of podocyte loss occurring as an early event in proteinuric kidney diseases might play a role in disease progression.
De Asha, Alan R; Johnson, Louise; Munjal, Ramesh; Kulkarni, Jai; Buckley, John G
2013-02-01
Disruptions to the progress of the centre-of-pressure trajectory beneath prosthetic feet have been reported previously. These disruptions reflect how body weight is transferred over the prosthetic limb and are governed by the compliance of the prosthetic foot device and its ability to simulate ankle function. This study investigated whether using an articulating hydraulic ankle attachment attenuates centre-of-pressure trajectory fluctuations under the prosthetic foot compared to a fixed attachment. Twenty active unilateral trans-tibial amputees completed walking trials at their freely-selected, comfortable walking speed using both their habitual foot with either a rigid or elastic articulating attachment and a foot with a hydraulic ankle attachment. Centre-of-pressure displacement and velocity fluctuations beneath the prosthetic foot, prosthetic shank angular velocity during stance, and walking speed were compared between foot conditions. Use of the hydraulic device eliminated or reduced the magnitude of posteriorly directed centre-of-pressure displacements, reduced centre-of-pressure velocity variability across single-support, increased mean forward angular velocity of the shank during early stance, and increased freely chosen comfortable walking speed (P ≤ 0.002). The attenuation of centre-of-pressure trajectory fluctuations when using the hydraulic device indicated bodyweight was transferred onto the prosthetic limb in a smoother, less faltering manner which allowed the centre of mass to translate more quickly over the foot. Copyright © 2012 Elsevier Ltd. All rights reserved.
Mildren, Robyn L; Bent, Leah R
2016-04-15
It has previously been shown that cutaneous sensory input from across a broad region of skin can influence proprioception at joints of the hand. The present experiment tested whether cutaneous input from different skin regions across the foot can influence proprioception at the ankle joint. The ability to passively match ankle joint position (17° and 7° plantar flexion and 7° dorsiflexion) was measured while cutaneous vibration was applied to the sole (heel, distal metatarsals) or dorsum of the target foot. Vibration was applied at two different frequencies to preferentially activate Meissner's corpuscles (45 Hz, 80 μm) or Pacinian corpuscles (255 Hz, 10 μm) at amplitudes ∼3 dB above mean perceptual thresholds. Results indicated that cutaneous input from all skin regions across the foot could influence joint-matching error and variability, although the strongest effects were observed with heel vibration. Furthermore, the influence of cutaneous input from each region was modulated by joint angle; in general, vibration had a limited effect on matching in dorsiflexion compared with matching in plantar flexion. Unlike previous results in the upper limb, we found no evidence that Pacinian input exerted a stronger influence on proprioception compared with Meissner input. Findings from this study suggest that fast-adapting cutaneous input from the foot modulates proprioception at the ankle joint in a passive joint-matching task. These results indicate that there is interplay between tactile and proprioceptive signals originating from the foot and ankle. Copyright © 2016 the American Physiological Society.
Pointing the foot without sickling: an examination of ankle movement during jumping.
Jarvis, Danielle N; Kulig, Kornelia
2015-03-01
The sauté is a relatively simple dance jump that can be performed by both highly skilled dancers and non-dancers. However, there are characteristics of jumping unique to trained dancers, especially in terms of foot and ankle movement during flight. Dancers are trained not to "sickle, " or to avoid the anatomically coupled ankle inversion that occurs with plantar flexion, maintaining the appearance of a straight line through the lower leg and foot. The purpose of this study was to examine ankle movements in elite dancers compared to non-dancers. Twenty healthy females, 10 with no prior dance training and 10 professional dancers, performed 20 consecutive sautés while three-dimensional kinematic data were collected. Sagittal and frontal plane kinematics were calculated and vector coding methods were used to quantify coordination patterns within the ankle in the sagittal and frontal planes. This pattern was chosen for analysis to identify the avoidance of a sickled foot by trained dancers. Peak ankle positions and coordination patterns between groups were examined using independent t-tests (a <0.05). Dancers demonstrated greater peak plantar flexion (p<0.01) and less change in ankle angle during the flight phase (p= 0.01), signifying holding the pointed foot position during flight. There was no statistically significant difference in sagittal and frontal plane ankle coupling (p= 0.15); however, the Cohen's d effect size for the difference in coupling was medium-to-large (0.73). Dynamic analysis of the foot and ankle during jumping demonstrates how elite dancers achieve the aesthetic requirements of dance technique.
Application of NIR spectroscopy in the assessment of diabetic foot disorders
NASA Astrophysics Data System (ADS)
Schleicher, Eckhard; Hampel, Uwe; Freyer, Richard
2001-10-01
Diabetic foot syndrome (DFS) is a common sequel of long-term diabetes mellitus. There is a urgent need of noninvasive, objective and quantitative diagnostic tools to assess tissue viability and perfusion for a successful therapy. NIR spectroscopy seems to be qualified to measure local capillary hemoglobin saturation of the outer extremities in patients with progressive diabetic disorders. We investigate how NIR spectroscopy can be applied to the assessment of diabetic foot problems such as neuropathy and angiopathy. Thereby we use spatially resolved spectroscopy in conjunction with a specially developed continuous-wave laser spectrometer. Comparison of intra- and interindividual measurements is expected to yield quantitative measures of local tissue viability which is a prerequisite for a successful therapy.
Stabilometric parameters are affected by anthropometry and foot placement.
Chiari, Lorenzo; Rocchi, Laura; Cappello, Angelo
2002-01-01
To recognize and quantify the influence of biomechanical factors, namely anthropometry and foot placement, on the more common measures of stabilometric performance, including new-generation stochastic parameters. Fifty normal-bodied young adults were selected in order to cover a sufficiently wide range of anthropometric properties. They were allowed to choose their preferred side-by-side foot position and their quiet stance was recorded with eyes open and closed by a force platform. biomechanical factors are known to influence postural stability but their impact on stabilometric parameters has not been extensively explored yet. Principal component analysis was used for feature selection among several biomechanical factors. A collection of 55 stabilometric parameters from the literature was estimated from the center-of-pressure time series. Linear relations between stabilometric parameters and selected biomechanical factors were investigated by robust regression techniques. The feature selection process returned height, weight, maximum foot width, base-of-support area, and foot opening angle as the relevant biomechanical variables. Only eleven out of the 55 stabilometric parameters were completely immune from a linear dependence on these variables. The remaining parameters showed a moderate to high dependence that was strengthened upon eye closure. For these parameters, a normalization procedure was proposed, to remove what can well be considered, in clinical investigations, a spurious source of between-subject variability. Care should be taken when quantifying postural sway through stabilometric parameters. It is suggested as a good practice to include some anthropometric measurements in the experimental protocol, and to standardize or trace foot position. Although the role of anthropometry and foot placement has been investigated in specific studies, there are no studies in the literature that systematically explore the relationship between such BF and stabilometric parameters. This knowledge may contribute to better defining the experimental protocol and improving the functional evaluation of postural sway for clinical purposes, e.g. by removing through normalization the spurious effects of body properties and foot position on postural performance.
Eslami, Mansour; Begon, Mickaël; Farahpour, Nader; Allard, Paul
2007-01-01
Based on twisted plate and mitered hinge models of the foot and ankle, forefoot-rearfoot coupling motion patterns can contribute to the amount of tibial rotation. The present study determined the differences of forefoot-rearfoot coupling patterns as well as excessive excursion of tibial internal rotation in shod versus barefoot conditions during running. Sixteen male subjects ran 10 times at 170 steps per minute under the barefoot and shod conditions. Forefoot-rearfoot coupling motions were assessed by measuring mean relative phase angle during five intervals of stance phase for the main effect of five time intervals and two conditions (ANOVA, P<0.05). Tibial internal rotation excursion was compared between the shod and barefoot conditions over the first 50% of stance phase using paired t-test, (P<0.05). Forefoot adduction/abduction and rearfoot eversion/inversion coupling motion patterns were significantly different between the conditions and among the intervals (P<0.05; effect size=0.47). The mean absolute relative angle was significantly modified to 37 degrees in-phase relationship at the heel-strike of running with shoe wears. No significant differences were noted in the tibial internal rotation excursion between shod and barefoot conditions. Significant variations in the forefoot adduction/abduction and rearfoot eversion/inversion coupling patterns could have little effect on the amount of tibial internal rotation excursion. Yet it remains to be determined whether changes in the frontal plane forefoot-rearfoot coupling patterns influence the tibia kinematics for different shoe wears or foot orthotic interventions. The findings question the rational for the prophylactic use of forefoot posting in foot orthoses.
Echegoyen, Soledad; Aoyama, Takeshi; Rodríguez, Cristina
2013-06-01
Zapateado is a repetitive percussive footwork in dance. This percussive movement, and the differences in technique, may be risk factors for injury. A survey on zapateado dance students found a rate of 1.5 injuries/1,000 exposures. Knee injuries are more frequent than in Spanish dancers than folkloric dancers. The aim of this research was to study the relationship between technique and ground reaction force between zapateado on Spanish and Mexican folkloric dancers. Ten female dance students (age 22.4 ± 4 yrs), six Spanish dancers and four Mexican folkloric dancers, were considered. Each student performed zapateado with a flat foot, wearing high-heeled shoes during 5 seconds on a force platform. Videotapes were taken on a lateral plane, and knee and hip angles in each movement phase were measured with Dartfish software. Additionally, knee and ankle flexor and extensor strength was measured with a dynamometer. Ground reaction forces were lower for Spanish dancers than Mexican folkloric dancers. Spanish dancers had less knee flexion when the foot contacted to the ground than did Mexican folkloric dancers. On Spanish dancers, the working leg had more motion in relation to hip and knee angles than was seen in folkloric dancers. The ankle extensors were stronger on folkloric dancers, and there were no differences for the other muscle groups. Knee flexion at foot contact and muscle strength imbalance could be risk factors for injuries. It is suggested that the technique in Spanish dance in Mexico be reviewed, although more studies are required to define more risk factors.
Watanabe, Takashi
2013-01-01
The wearable sensor system developed by our group, which measured lower limb angles using Kalman-filtering-based method, was suggested to be useful in evaluation of gait function for rehabilitation support. However, it was expected to reduce variations of measurement errors. In this paper, a variable-Kalman-gain method based on angle error that was calculated from acceleration signals was proposed to improve measurement accuracy. The proposed method was tested comparing to fixed-gain Kalman filter and a variable-Kalman-gain method that was based on acceleration magnitude used in previous studies. First, in angle measurement in treadmill walking, the proposed method measured lower limb angles with the highest measurement accuracy and improved significantly foot inclination angle measurement, while it improved slightly shank and thigh inclination angles. The variable-gain method based on acceleration magnitude was not effective for our Kalman filter system. Then, in angle measurement of a rigid body model, it was shown that the proposed method had measurement accuracy similar to or higher than results seen in other studies that used markers of camera-based motion measurement system fixing on a rigid plate together with a sensor or on the sensor directly. The proposed method was found to be effective in angle measurement with inertial sensors. PMID:24282442
Macrodystrophia lipomatosa. A case report.
Loro, A; Francechi, F; Dal Lago, A
1995-07-01
Macrodystrophia lipomatosa, a rare form of localized gigantism of unknown cause, is characterized by a dramatic overgrowth of all the mesenchymal elements, particularly the fibroadipose tissue, of one or more digits of the foot or hand. Of the known forms, static and progressive (1), we report the case of an African patient, of Bantu origin, who had a progressive deformity of his left hand.
Feng, S M; Wang, A G; Ding, P; Zhang, Z Y; Zhou, M M; Li, C K; Sun, Q Q
2016-07-26
To explore the surgical method of using the modified chevron osteotomy combined distal soft tissue reconstruction to treat high-grade bunionette deformity. From June 2013 to June 2015, the modified chevron osteotomy combined distal soft tissue reconstruction was used for surgical treatment of high-grade bunionette deformity in the Department of Hand and Foot Microsurgery in Xuzhou Central Hospital.Twenty-six patients with 28 feet high-grade bunionette deformity were hospitalized for treatment, with 3 male (3 feet) and 23 female (25 feet) cases, aged 22-73 (mean 47.1) years old.The average fourth-fifth intermetatarsal angle, lateral deviation of the fifth metatarsal angle and metatarsophalangeal-fifth angle were measured on the pre-and post- operative anterior to posterior weight-beating X rays of treated feet.The American Orthopaedic Foot and Ankle Society (AOFAS) Lesser Toe Metatarsophalangeal-Interphalangeal Scale was used to evaluate the post-operative outcomes. All of 26 patients were followed, with a mean 15.7 months (range 8-25 months). Primarily healing of the wound was achieved in all cases.No postoperative infection and nonunion on the osteotomy site was found during the follow-up time.The fracture healing time was 6-15 (mean 12.2) weeks.All the patients had satisfactory appearance and sensory function without callosum and metastatic metatarsalgia at the final follow-up.The post-operative fourth-fifth intermetatarsal angle, lateral deviation of the fifth metatarsal angle and metatarsophalangeal-fifth angle were significantly lesser than the pre-operative at the 6th week after operation, respectively [(5.5±1.7)°, (2.1±0.8)°, (5.7±2.6)°vs (16.4±4.2)°, (6.0±2.2)°, (10.5±7.4)°; all P<0.01]. The post-operative AOFAS score was significantly greater than the pre-operative [(87.1±6.7) vs (62.3±9.8) points, P<0.001]. The modified chevron osteotomy combined distal soft tissue reconstruction is a safe and easy treatment option for the high-grade bunionette deformity and provides patient satisfaction results.
Assessment of a Conceptual Flap System Intended for Enhanced General Aviation Safety
NASA Technical Reports Server (NTRS)
Campbell, Bryan A.; Carter, Melissa B.
2017-01-01
A novel multielement trailing-edge flap system for light general aviation airplanes was conceived for enhanced safety during normal and emergency landings. The system is designed to significantly reduce stall speed, and thus approach speed, with the goal of reducing maneuveringflight accidents and enhancing pilot survivability in the event of an accident. The research objectives were to assess the aerodynamic performance characteristics of the system and to evaluate the extent to which it provided both increased lift and increased drag required for the low-speed landing goal. The flap system was applied to a model of a light general aviation, high-wing trainer and tested in the Langley 12- Foot Low-Speed Wind Tunnel. Data were obtained for several device deflection angles, and component combinations at a dynamic pressure of 4 pounds per square foot. The force and moment data supports the achievement of the desired increase in lift with substantially increased drag, all at relatively shallow angles of attack. The levels of lift and drag can be varied through device deflection angles and inboard/outboard differential deflections. As such, it appears that this flap system may provide an enabling technology to allow steep, controllable glide slopes for safe rapid descent to landing with reduced stall speed. However, a simple flat-plate lower surface spoiler (LSS) provided either similar or superior lift with little impact on pitch or drag as compared to the proposed system. Higher-fidelity studies are suggested prior to use of the proposed system.
Pillai, Anand; Basappa, Prabhudeva; Ehrendorfer, Stefan
2007-02-01
We describe a modification of the classical Essex-Lopresti manoeuvre for the indirect reduction and stabilisation of displaced intra-articular fractures of the calcaneus. The radiological and functional results achieved using this technique in 15 patients is presented. Ten tongue-shaped and 8 joint depression type fractures were treated by the new method, incorporating the use of an additional traction pin. The pre and postoperative Böhler angles as well as the correction achieved were documented. Functional assessment was carried out using the Maryland Foot Score. The mean pre-operative Böhler angle in the joint depression group was 5.5 degrees, and in the tongue shaped fracture group 5 degrees. The mean postoperative Böhler angle in the joint depression group was 15.8 degrees, and in the tongue shape group was 23.25 degrees. At a mean follow-up of 28 months the joint depression group scored 51/100 on the foot score, and the tongue shaped fracture group 77/100. The mean correction achieved as well as the mean overall functional scores were significantly better in the tongue shaped group. The technique described has much promise in the management of selected displaced intra-articular fractures of the calcaneus (true tongue shaped / Sanders II), and may also have a limited role in other fracture types in patients with significant co-morbidities, soft tissue compromise and poor healing potential.
Kanatlı, Ulunay; Aktas, Erdem; Yetkin, Haluk
2016-09-01
Flexible flatfoot, as the most prevalent foot deformity in pediatric population still has no standardized strategy for its management hence some orthopedic surgeons have the tendency to use orthotic devices. The objective of this study is to evaluate whether orthotic shoes effect the natural course of the developing medial longitudinal arch in children diagnosed with moderate flexible flatfoot. Fourty-five children (33 boys and 12 girls) with moderate flexible flatfoot were enrolled in this study. They were followed up for 34.6 ± 10.9 months (24-57 months). Patients in group 1 were treated with corrective shoes whereas group 2 was left untreated. Patients were evaluated according to; general joint laxity, arch index, lateral talo-first metatarsal (TM), talo-horizontal (TH), calcaneal pitch (CP), lateral and anterior talocalcaneal (TC) angles. Although there was a significant decrease in general laxity in both groups, decrease of laxity percentage was not significant between groups (p = 0.812). TM, TH and anterior TC angles were found to be decreased in groups whereas there was no difference between group 1 and 2. The arch index was found to be correlated with TM and TH angles in both groups (p = 0.004, p = 0.013). Corrective shoes for flexible flatfoot was found not effective on development of foot arches. Therefore, they should be limited only for selected cases. Copyright © 2016 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.
Knee Brace Would Lock And Unlock Automatically
NASA Technical Reports Server (NTRS)
Myers, Neill; Forbes, John; Shadoan, Mike; Baker, Kevin
1995-01-01
Proposed knee brace designed to aid rehabilitation of person who suffered some muscle damage in leg. Not limited to locking in straight-leg position and, instead, locks at any bend angle. Does not prevent knee from bearing weight. Instead, knee brace allows knee to bear weight and locks only when foot and lower leg bear weight. Thus, brace prevents flexion that wearer desired to prevent but could not prevent because of weakened muscles. Knee bends freely to exercise knee-related muscles. Knee brace strapped at upper end to leg above knee, and anchored at lower end by stirrup under foot. Joint mechanism (identical mechanisms used in left and right assemblies) allows knee joint to flex freely except when weight applied to heel.
NASA Technical Reports Server (NTRS)
Reubush, D. E.; Mercer, C. E.
1974-01-01
A wind-tunnel investigation has been conducted to determine the exhaust-nozzle aerodynamic and propulsive characteristics for a twin-jet variable-wing-sweep fighter airplane model. The powered model was tested in the Langley 16-foot transonic tunnel and in the Langley 4-foot supersonic pressure tunnel at Mach numbers to 2.2 and at angles of attack from about minus 2 to 6 deg. Compressed air was used to simulate the nozzle exhaust flow at values of jet total-pressure ratio from approximately 1 (jet off) to about 21. Effects of configuration variables such as speed-brake deflection, store installation, and boundary-layer thickness on the the nozzle characteristics were also investigated.
NASA Technical Reports Server (NTRS)
Rossow, V. J.; Corsiglia, V. R.; Phillippe, J. J.
1974-01-01
The rolling moment induced on aircraft models in the wake of a model of a subsonic transport and of a supersonic transport was measured as a function of angle of attack for several configurations. The tests are described and an analysis of the data is given in this memorandum.
NASA Technical Reports Server (NTRS)
Rogge, R. L.
1974-01-01
Strut support interference investigations were conducted on an 0.004-(-) scale representation of the space shuttle launch vehicle in order to determine transonic and supersonic model support interference effects for use in a future exhaust plume effects study. Strut configurations were also tested. Orbiter, external tank, and solid rocket booster pressures were recorded at Mach numbers 0.9, 1.2, 1.5, and 2.0. Angle of attack and angle of sideslip were varied between plus or minus 4 degrees in 2 degree increments. Parametric variations consisted only of the strut configurations.
NASA Technical Reports Server (NTRS)
Flechner, S. G.
1979-01-01
A wind tunnel investigation to identify changes in stability and control characteristics of a model KC-135A due to the addition of winglets is presented. Static longitudinal and lateral-directional aerodynamic characteristics were determined for the model with and without winglets. Variations in the aerodynamic characteristics at various Mach numbers, angles of attack, and angles of slidslip are discussed. The effect of the winglets on the drag and lift coefficients are evaluated and the low speed and high speed characteristics of the model are reported.
NASA Technical Reports Server (NTRS)
Green, Robert S.; Carson, George T., Jr.
1987-01-01
An investigation was conducted in the Langley 16-Foot Transonic Tunnel at static conditions to measure the pressure distributions inside a nonaxisymmetric nozzle with simultaneous partial thrust reversing (50-percent deployment) and thrust vectoring of the primary (forward-thrust) nozzle flow. Geometric forward-thrust-vector angles of 0 and 15 deg. were tested. Test data were obtained at static conditions while nozzle pressure ratio was varied from 2.0 to 4.0. Results indicate that, unlike the 0 deg. vector angle nozzle, a complicated, asymmetric exhaust flow pattern exists in the primary-flow exhaust duct of the 15 deg. vectored nozzle.
NASA Technical Reports Server (NTRS)
Mugler, John P., Jr.
1959-01-01
Pressure distributions obtained in the Langley 8-foot transonic pressure tunnel on a thin, highly tapered, twisted, 45 deg sweptback wing in combination with a body are presented. The wing has a linear span-wise twist variation from 0 deg at 10 percent of the semispan to 6 deg at the tip. The tip is at a lower angle of attack than the root. Tests were made at stagnation pressures of 1.0 and 0.5 atmosphere, at Mach numbers from 0.800 to 1.200, and at angles of attack from -4 to 12 deg.
NASA Technical Reports Server (NTRS)
1976-01-01
An experimental and analytical aerodynamic program to develop predesign guides for irregular planform wings is reported. The benefits are linearization of subsonic lift curve slope to high angles of attack and avoidance of subsonic pitch instabilities at high lift by proper tailoring of the planform fillet wing combination while providing the desired hypersonic trim angle and stability. The two prime areas of concern are to optimize shuttle orbiter landing and entry characteristics. Basic longitudinal aerodynamic characteristics at high supersonic speeds are developed.
NASA Technical Reports Server (NTRS)
West, F E
1945-01-01
Lift characteristics and pressure distribution for a NACA 230 wing were investigated for an angle of attack range of from -10 to +24 degrees and Mach range of from 0.2 to 0.7. Maximum lift coefficient increased up to a Mach number of 0.3, decreased rapidly to a Mach number of 0.55, and then decreased moderately. At high speeds, maximum lift coefficient was reached at from 10 to 12 degrees beyond the stalling angle. In high-speed stalls, resultant load underwent a moderate shift outward.
Transonic wind tunnel tests of a .015 scale space shuttle booster model
NASA Technical Reports Server (NTRS)
Dennis, R. J.
1972-01-01
Details of the test program, an outline of the test procedure, and results of the investigation in tabular form are presented. The base drag reduction potential was determined at cruise conditions (M = .40) of a modified base region, with and without base bleed flow. Transonic effects and cruise control effectiveness of the new base region were also obtained. The tests were performed at Mach numbers from 0.40 to 1.10, at angles of attack from -4 to +20 degrees and at angles of sideslip from -6 to +6 degrees, all at a Reynolds number of 6.56 million per meter (2.0 million per foot).
Background noise levels measured in the NASA Lewis 9- by 15-foot low-speed wind tunnel
NASA Technical Reports Server (NTRS)
Woodward, Richard P.; Dittmar, James H.; Hall, David G.; Kee-Bowling, Bonnie
1994-01-01
The acoustic capability of the NASA Lewis 9 by 15 Foot Low Speed Wind Tunnel has been significantly improved by reducing the background noise levels measured by in-flow microphones. This was accomplished by incorporating streamlined microphone holders having a profile developed by researchers at the NASA Ames Research Center. These new holders were fabricated for fixed mounting on the tunnel wall and for an axially traversing microphone probe which was mounted to the tunnel floor. Measured in-flow noise levels in the tunnel test section were reduced by about 10 dB with the new microphone holders compared with those measured with the older, less refined microphone holders. Wake interference patterns between fixed wall microphones were measured and resulted in preferred placement patterns for these microphones to minimize these effects. Acoustic data from a model turbofan operating in the tunnel test section showed that results for the fixed and translating microphones were equivalent for common azimuthal angles, suggesting that the translating microphone probe, with its significantly greater angular resolution, is preferred for sideline noise measurements. Fixed microphones can provide a local check on the traversing microphone data quality, and record acoustic performance at other azimuthal angles.
The modified distal horizontal metatarsal osteotomy for correction of bunionette deformity.
Radl, Roman; Leithner, Andreas; Koehler, Wolfgang; Scheipl, Susanne; Windhager, Reinhard
2005-06-01
Bunionette is a common deformity for which a number of operative procedures have been described. The objective of this study was to evaluate the results of a modified distal horizontal metatarsal osteotomy in the correction of symptomatic bunionette. Metatarsal osteotomies were done in 21 feet in 14 patients (11 females, three males) with an average age of 44 (range 20 to 67) years at the time of operation. The average followup was 32 (range 12 to 52) months. The average Lesser Toe Metatarsophalangeal-Interphalangeal Score of the American Orthopaedic Foot and Ankle Society increased from 42 points (range 24 to 50) preoperatively to 87 points (range 60 to 100) at the last followup. The fifth metatarsophalangeal angle averaged 18 degrees (5 to 38 degrees) preoperatively and 5 degrees (-5 to 26 degrees) at final followup. The 4-5 intermetatarsal angle averaged 14 degrees (10 to 20 degrees) preoperatively and 9 degrees (5 to 12 degrees) at final followup. Hardware was removed from two feet and scheduled for a third foot because of symptomatic skin irritation. The modified distal horizontal metatarsal osteotomy is a stable and reliable method for correction of bunionette. Unsatisfactory results in our patients were related to prominent hardware.
Effect of soccer shoe upper on ball behaviour in curve kicks
Ishii, Hideyuki; Sakurai, Yoshihisa; Maruyama, Takeo
2014-01-01
New soccer shoes have been developed by considering various concepts related to kicking, such as curving a soccer ball. However, the effects of shoes on ball behaviour remain unclear. In this study, by using a finite element simulation, we investigated the factors that affect ball behaviour immediately after impact in a curve kick. Five experienced male university soccer players performed one curve kick. We developed a finite element model of the foot and ball and evaluated the validity of the model by comparing the finite element results for the ball behaviour immediately after impact with the experimental results. The launch angle, ball velocity, and ball rotation in the finite element analysis were all in general agreement with the experimental results. Using the validated finite element model, we simulated the ball behaviour. The simulation results indicated that the larger the foot velocity immediately before impact, the larger the ball velocity and ball rotation. Furthermore, the Young's modulus of the shoe upper and the coefficient of friction between the shoe upper and the ball had little effect on the launch angle, ball velocity, and ball rotation. The results of this study suggest that the shoe upper does not significantly influence ball behaviour. PMID:25266788
A three-dimensional orthogonal laser velocimeter for the NASA Ames 7- by 10-foot wind tunnel
NASA Technical Reports Server (NTRS)
Dunagan, Stephen E.; Cooper, Donald L.
1995-01-01
A three-component dual-beam laser-velocimeter system has been designed, fabricated, and implemented in the 7-by 10-Foot Wind Tunnel at NASA Ames Research Center. The instrument utilizes optical access from both sides and the top of the test section, and is configured for uncoupled orthogonal measurements of the three Cartesian coordinates of velocity. Bragg cell optics are used to provide fringe velocity bias. Modular system design provides great flexibility in the location of sending and receiving optics to adapt to specific experimental requirements. Near-focus Schmidt-Cassegrain optic modules may be positioned for collection of forward or backward scattered light over a large solid angle, and may be clustered to further increase collection solid angle. Multimode fiber optics transmit collected light to the photomultiplier tubes for processing. Counters are used to process the photomultiplier signals and transfer the processed data digitally via buffered interface controller to the host MS-DOS computer. Considerable data reduction and graphical display programming permit on-line control of data acquisition and evaluation of the incoming data. This paper describes this system in detail and presents sample data illustrating the system's capability.
Nakada, Izumi; Nakamura, Ichiro; Juji, Takuo; Ito, Katsumi; Matsumoto, Takumi
2015-09-01
Compensatory hindfoot alignment for deformities at the knee level has been demonstrated in patients with knee osteoarthritis. However, this phenomenon has not been elucidated in patients with rheumatoid arthritis (RA). The aim of this study is to investigate the relationship between knee deformity and hindfoot alignment and the effect of subtalar joint destruction in patients with RA. We retrospectively investigated RA patients (110 patients, 205 limbs) using radiographs in the standing anteroposterior knee, standing lateral foot, and hindfoot alignment views. The grade of destruction at the knee and subtalar joints was assigned using Larsen's grading system. The correlation between the femorotibial and tibiocalcaneal angles and the effect of joint destruction on this correlation were analyzed using Pearson's correlation coefficients. There was moderate correlation between the femorotibial and tibiocalcaneal angles in a group of knees with a Larsen grade of ≥ 4 (r = 0.544, p = 0.0239). This correlation was stronger in a group with less damaged subtalar joints with a Larsen grade of ≤ 3 (r = 0.705, p = 0.0049). These findings emphasized the importance of examining foot and ankles in patients with RA who undergo total knee arthroplasty.
Parr, W C H; Chatterjee, H J; Soligo, C
2012-04-05
Orientation of the subtalar joint axis dictates inversion and eversion movements of the foot and has been the focus of evolutionary and clinical studies for a number of years. Previous studies have measured the subtalar joint axis against the axis of the whole foot, the talocrural joint axis and, recently, the principal axes of the talus. The present study introduces a new method for estimating average joint axes from 3D reconstructions of bones and applies the method to the talus to calculate the subtalar and talocrural joint axes. The study also assesses the validity of the principal axes as a reference coordinate system against which to measure the subtalar joint axis. In order to define the angle of the subtalar joint axis relative to that of another axis in the talus, we suggest measuring the subtalar joint axis against the talocrural joint axis. We present corresponding 3D vector angles calculated from a modern human skeletal sample. This method is applicable to virtual 3D models acquired through surface-scanning of disarticulated 'dry' osteological samples, as well as to 3D models created from CT or MRI scans. Copyright © 2012 Elsevier Ltd. All rights reserved.
Effect of soccer shoe upper on ball behaviour in curve kicks
NASA Astrophysics Data System (ADS)
Ishii, Hideyuki; Sakurai, Yoshihisa; Maruyama, Takeo
2014-08-01
New soccer shoes have been developed by considering various concepts related to kicking, such as curving a soccer ball. However, the effects of shoes on ball behaviour remain unclear. In this study, by using a finite element simulation, we investigated the factors that affect ball behaviour immediately after impact in a curve kick. Five experienced male university soccer players performed one curve kick. We developed a finite element model of the foot and ball and evaluated the validity of the model by comparing the finite element results for the ball behaviour immediately after impact with the experimental results. The launch angle, ball velocity, and ball rotation in the finite element analysis were all in general agreement with the experimental results. Using the validated finite element model, we simulated the ball behaviour. The simulation results indicated that the larger the foot velocity immediately before impact, the larger the ball velocity and ball rotation. Furthermore, the Young's modulus of the shoe upper and the coefficient of friction between the shoe upper and the ball had little effect on the launch angle, ball velocity, and ball rotation. The results of this study suggest that the shoe upper does not significantly influence ball behaviour.
Zhou, Haichao; Ren, Haoyang; Li, Bing; Yu, Tao; Yang, Yunfeng
2016-07-08
?To discuss the effectiveness of limited open reduction via sinus tarsi approach using medial distraction technique in the treatment of intra-articular calcaneus fractures by comparing with open reduction and internal fixation via extensile L-shaped incision. ?A retrospective analysis was made on the clinical data of 21 patients with intra-articular calcaneus fractures treated by sinus tarsi approach combined with medial distraction technique between April 2013 and November 2014 (minimally invasive group), and 32 patients treated by extensile L-shaped incision approach between June 2012 and September 2014 (extensile incision group). No significant difference was found in gender, age, injury pattern, fracture classification, time from injury to operation, preoperative Böhler angle, Gissane angle, calcaneal varus angle, the ankle and hind-foot score of American Orthopaedic Foot and Ankle Society (AOFAS), and visual analogue scale (VAS) score between 2 groups (P>0.05), which was comparable. The operation time, wound complications, and bone healing time were recorded. The postoperative function was also evaluated by AOFAS score and VAS score. The pre-and post-operative Böhler angle, Gissane angle, and calcaneal varus angle were measured on the X-ray films, and the corrective angle was calculated. ?Sixteen patients were followed up 6-18 months (mean, 11.5 months) in the minimally invasive group, and 23 patients for 6-24 months (mean, 13.5 months) in the extensile incision group. Difference was not significant in operation time between 2 groups (t=0.929, P=0.796). No complication occurred in the minimally invasive group; partial skin flap necrosis occurred in 3 cases of the extensile incision group, was cured after dressing change. There was no loosening of implants or reduction loss in 2 groups at last follow-up. Subtalar joint stiffness occurred in 1 case of the minimally invasive group and 4 cases of the extensile incision group, and 1 patient had discomfort for the implants in the extensile incision group. The bone healing time was (9.9±0.8) weeks in the minimally invasive group, and was (10.1±0.7) weeks in the extensile incision group, showing no significant difference (t=0.613, P=0.845 ). Böhler angle, Gissane angle, calcaneal varus angle, AOFAS score, and VAS score were significantly improved at last follow-up when compared with preoperative values in 2 groups (P<0.05), but there was no significant difference between 2 groups (P>0.05), and the corrective value of angle showed no significant difference between 2 groups (P>0.05). ?Limited open reduction via sinus tarsi approach for intra-articular calcaneus fractures could reduce the incidence of wound complications effectively. Meanwhile, the medial distraction technique is helpful to correct the heel varus deformity.
Emmerich, J; Wülker, N; Hurschler, C
2003-04-01
The respective contributions of the active and passive structures of the foot to the stability of the medical arch were investigated using an in vitro kinetic and kinematic model. The effect of the tibialis posterior tendon on foot and ankle movements, and plantar pressure distribution of the foot were tested in a cadaveric human foot. The stance phase from heel-contact to toe-off of normal walking gait and after tibialis posterior tendon rupture was simulated in eight roentenographically normal human feet (age 66 +/- 19 years, males). Ground reaction force and tibial inclination was simulated by means of a tilting angle and force-controlled translation stage. Plantar pressure was measured using a pressure-measuring platform. The force developed by the flexors and extensor muscles of the foot were simulated via cables attached to 7 force-controlled hydraulic cylinders. Tibial rotation was produced by an electric servo-motor, and foot movements measured with an ultrasonic analysis system. The model was verified against the plantar distribution and kinematics of healthy subjects measured during normal gait. Tibialis posterior deficit did not result in any detectable changes in pressure or force-time integral in the medial regions of the foot--a common sign of flat foot (pressure: midfoot 0.2 < or = 0.9; medial forefoot 0.5 < or = p < or = 0.9; hallux 0.5 < or = p < or = 0.9; force-time integral: midfoot p = 0-871; medial forefoot p = 0.632; hallux p = 0.068). Only small tendential changes in the kinematics of the talus and calcaneus were observed in dorsiflexion (0-58 sec; talus 0.1 < or = p < or = 0.6; calcaneus 0.4 < or = p < or = 0.06) and eversion (talus: 0-60 sec. 0.1 < or = p < or = 0.6; calcaneus: 37-60 sec. 0.2 < or = p < or = 0.7). The results of this in vitro study show that defective tibialis posterior alone does not produce significant changes in the kinetics or kinematics of the stance phase of normal gait. This suggests that the development of flat foot observed in degeneration of the tibialis posterior tendon occurs only after fatigue of the passive structures of the foot.
Moncayo, Roy; Moncayo, Helga
2007-01-01
Background Low level connective tissue inflammation has been proposed to play a role in thyroid associated ophthalmopathy (TAO). The aim of this study was to investigate this postulate by a musculoskeletal approach together with biochemical parameters. Methods 13 patients with TAO and 16 controls were examined. Erythrocyte levels of Zn, Cu, Ca2+, Mg, and Fe were determined. The musculoskeletal evaluation included observational data on body posture with emphasis on the orbit-head region. The angular foot position in the frontal plane was quantified following gait observation. The axial orientation of the legs and feet was evaluated in an unloaded supine position. Functional propioceptive tests based on stretch stimuli were done by using foot inversion and foot rotation. Results Alterations in the control group included neck tilt in 3 cases, asymmetrical foot angle during gait in 2, and a reaction to foot inversion in 5 cases. TAO patients presented facial asymmetry with displaced eye fissure inclination (mean 9.1°) as well as tilted head-on-neck position (mean 5.7°). A further asymmetry feature was external rotation of the legs and feet (mean 27°). Both foot inversion as well as foot rotation induced a condition of neuromuscular deficit. This condition could be regulated by gentle acupressure either on the lateral abdomen or the lateral ankle at the acupuncture points gall bladder 26 or bladder 62, respectively. In 5 patients, foot rotation produced a phenomenon of moving toes in the contra lateral foot. In addition foot rotation was accompanied by an audible tendon snapping. Lower erythrocyte Zn levels and altered correlations between Ca2+, Mg, and Fe were found in TAO. Conclusion This whole body observational study has revealed axial deviations and body asymmetry as well as the phenomenon of moving toes in TAO. The most common finding was an arch-like displacement of the body, i.e. eccentric position, with foot inversion and head tilt to the contra lateral side and tendon snapping. We propose that eccentric muscle action over time can be the basis for a low grade inflammatory condition. The general implications of this model and its relations to Zn and Se will be discussed. PMID:17319961
Computerized planimetry evaluation of hyperbaric oxygen therapy in the treatment of diabetic foot.
Kawecki, Marek; Pasek, Jarosław; Cieślar, Grzegorz; Sieroń, Aleksander; Knefel, Grzegorz; Nowak, Mariusz; Glik, Justyna
2018-01-01
Diabetic foot ulcer is one of the major complications of diabetes mellitus in adults. The aim of the study was to conduct a planimetry evaluation of the effectiveness of hyperbaric oxygen therapy (HBOT) in the treatment of patients with vascular disorders caused by diabetic foot. The study included 94 patients, 30 females (32%) and 64 males (68%), aged 33-76 years, with diabetes lasting 1.5-32 years, who underwent HBOT due to diabetic foot. All patients from that group underwent vascular procedures prior to HBOT. In qualifying patients for hyperbaric oxygen therapy, transcutaneous oximetry method was applied (30-60 exposures in hyperbaric oxygen at pressure of 2.5 ATA). Progress in wound healing was evaluated by computerized planimetry system IRIS 4. In 26 patients the wounds were completely closed and in 37 patients the topical state was significantly improved - the wound surface decreased by 34% in average. During the treatment, in 11 patients amputation of fingers and metatarsal necrotic bones was performed, while in 9 patients amputation was prevented. A planimetry evaluation showed that the application of HBOT in the treatment of diabetic foot enhances foot ulcer healing, reduces tissue damage, contributes to the reduction of complications related to soft tissue and bone infections.
Zollo, L; Zaccheddu, N; Ciancio, A L; Morrone, M; Bravi, M; Santacaterina, F; Laineri Milazzo, M; Guglielmelli, E; Sterzi, S
2015-04-01
Ankle-foot-orthoses (AFOs) are frequently prescribed for hemiparetic patients to compensate for the foot drop syndrome. However, there is not a systematic study either on the effectiveness of AFOs in the gait recovery process or pointing out the therapeutic differences among the various types of AFOs available on the market. To perform a comparative evaluation of solid and dynamic Ankle-Foot-Orthoses (AFOs) on hemiparetic patients affected by foot drop syndrome by means of spatio-temporal, kinematic and electromyographic indicators. Crossover design with randomization for the interventions. A rehabilitation center for adults with neurologic disorders. Ten chronic hemiparetic patients with foot drop syndrome met inclusion criteria and volunteered to participate. Biomechanical gait analysis was carried out on hemiparetic subjects with foot drop syndrome under 3 conditions with randomized sequences: 1) without AFO; 2) wearing a solid AFO; 3) wearing a dynamic AFO. Significant changes in spatio-temporal, kinematic and electromyographic features of gait were investigated. Gait analysis outcomes showed that there were no significant differences among the solid and the dynamic AFO on the spatio-temporal parameters. Both AFOs led to a reduction of the range of motion of the ankle dorsi-plantar-flexion during stance with respect to the ambulation without AFO. They also had the effect of reducing the asymmetry between the paretic and the contralateral limb in terms of ankle angle at initial contact and hip flexion. The solid AFO generally led to an increase of the co-contraction of the couples of muscles involved in the gait. The proposed set of indicators showed that the AFOs were capable of limiting the effect of the foot-drop in hemiparetic patients and balancing the two limbs. Main differences between the two orthoses were related to muscular activity, being the level of co-contraction of the two couples of analysed muscles typically lower when the dynamic AFO was worn and closer to a normal pattern. A more extensive use of the proposed indicators in the clinical practice is expected in order to enable the definition of clinical guidelines for the prescription of the two devices.
NASA Technical Reports Server (NTRS)
1976-01-01
A Langley-built 0.015-scale SSV orbiter configuration with remote independently operated left and right elevon surfaces was tested in the NASA/Langley Research Center Low Turbulence Pressure Tunnel. A detailed aerodynamic data base was obtained for the current shuttle orbiter configuration. Special attention was directed to definition of Reynolds number effects on nonlinear aerodynamic characteristics of the orbiter. Small increments in angle of attack, sideslip, and elevon/aileron position were studied in order to better define areas where nonlinearities may occur. Force and moment, and elevon position data were recorded over an angle of attack range -2 deg to 20 deg at angles of sideslip of 0 deg , + or - 2 deg, and + or - 4 deg. Tests were also made over an angle of sideslip range of -6 deg to 6 deg at selected angles of attack and elevon/aileron position. The test Mach numbers were from 0.15 to 0.30 at Reynolds numbers from 2.0 to 13.5 million per foot.
NASA Technical Reports Server (NTRS)
Page, V. R.; Eckert, W. T.; Mort, K. W.
1977-01-01
An experimental, aerodynamic investigation was made of two 1.83 m diameter fan systems which are being considered for the repowered drive section of the 40- by 80-foot wind tunnel at NASA Ames Research Center. One system was low speed, the other was high speed. The low speed fan was tested at various stagger angles from 32.9 deg to 62.9 deg. At a fan blade stagger angle of 40.8 deg and operating at a tip speed of 1155 m/sec, the low speed fan developed 207.3 m of head. The high speed fan had a design blade stagger angle of 56.2 deg and was tested at this stagger angle only. The high speed fan operating at 191.5 m/sec developed 207.3 m of head. Radial distributions of static pressure coefficients, total pressure coefficients, and angles of swirl are presented. Radial surveys were conducted at four azimuth locations in front of the fan, and repeated downstream of the fan. Data were taken for various flow control devices and for two inlet contraction lengths.
NASA Technical Reports Server (NTRS)
Whipple, R. D.; Ricket, J. L.
1986-01-01
A 1/8-scale model of the X-29A airplane was tested in the Ames 12-Foot Pressure Wind Tunnel at a Mach number of 0.20 and Reynolds numbers of 0.13 x 10 to the 6th power to 2.00 x 10 to the 6th power based on a fuselage forebody depth of 0.4 ft, For the test series presented herein, the angle of attack ranged from 40 deg. to 90 deg. and the angle of sideslip ranged from -10 deg. to 30 deg. for the erect attitude. Tests with the model inverted covered angles of attack from -40 deg. to -90 deg. and angles of sideslip from -30 deg. to 10 deg. Data were obtained for the basic design and for several forebody strakes. An alternate forebody design was also tested. The results provided information for selection of forebody strakes for compensation of Reynolds number effect on the 1/25-scale free-spinning model tested in the Langley Spin Tunnel.
Effects of Ankle Arthrodesis on Biomechanical Performance of the Entire Foot
Wang, Yan; Li, Zengyong; Wong, Duo Wai-Chi; Zhang, Ming
2015-01-01
Background/Methodology Ankle arthrodesis is one popular surgical treatment for ankle arthritis, chronic instability, and degenerative deformity. However, complications such as foot pain, joint arthritis, and bone fracture may cause patients to suffer other problems. Understanding the internal biomechanics of the foot is critical for assessing the effectiveness of ankle arthrodesis and provides a baseline for the surgical plan. This study aimed to understand the biomechanical effects of ankle arthrodesis on the entire foot and ankle using finite element analyses. A three-dimensional finite element model of the foot and ankle, involving 28 bones, 103 ligaments, the plantar fascia, major muscle groups, and encapsulated soft tissue, was developed and validated. The biomechanical performances of a normal foot and a foot with ankle arthrodesis were compared at three gait instants, first-peak, mid-stance, and second-peak. Principal Findings/Conclusions Changes in plantar pressure distribution, joint contact pressure and forces, von Mises stress on bone and foot deformation were predicted. Compared with those in the normal foot, the peak plantar pressure was increased and the center of pressure moved anteriorly in the foot with ankle arthrodesis. The talonavicular joint and joints of the first to third rays in the hind- and mid-foot bore the majority of the loading and sustained substantially increased loading after ankle arthrodesis. An average contact pressure of 2.14 MPa was predicted at the talonavicular joint after surgery and the maximum variation was shown to be 80% in joints of the first ray. The contact force and pressure of the subtalar joint decreased after surgery, indicating that arthritis at this joint was not necessarily a consequence of ankle arthrodesis but rather a progression of pre-existing degenerative changes. Von Mises stress in the second and third metatarsal bones at the second-peak instant increased to 52 MPa and 34 MPa, respectively, after surgery. These variations can provide indications for outcome assessment of ankle arthrodesis surgery. PMID:26222188
Effects of Ankle Arthrodesis on Biomechanical Performance of the Entire Foot.
Wang, Yan; Li, Zengyong; Wong, Duo Wai-Chi; Zhang, Ming
2015-01-01
Ankle arthrodesis is one popular surgical treatment for ankle arthritis, chronic instability, and degenerative deformity. However, complications such as foot pain, joint arthritis, and bone fracture may cause patients to suffer other problems. Understanding the internal biomechanics of the foot is critical for assessing the effectiveness of ankle arthrodesis and provides a baseline for the surgical plan. This study aimed to understand the biomechanical effects of ankle arthrodesis on the entire foot and ankle using finite element analyses. A three-dimensional finite element model of the foot and ankle, involving 28 bones, 103 ligaments, the plantar fascia, major muscle groups, and encapsulated soft tissue, was developed and validated. The biomechanical performances of a normal foot and a foot with ankle arthrodesis were compared at three gait instants, first-peak, mid-stance, and second-peak. Changes in plantar pressure distribution, joint contact pressure and forces, von Mises stress on bone and foot deformation were predicted. Compared with those in the normal foot, the peak plantar pressure was increased and the center of pressure moved anteriorly in the foot with ankle arthrodesis. The talonavicular joint and joints of the first to third rays in the hind- and mid-foot bore the majority of the loading and sustained substantially increased loading after ankle arthrodesis. An average contact pressure of 2.14 MPa was predicted at the talonavicular joint after surgery and the maximum variation was shown to be 80% in joints of the first ray. The contact force and pressure of the subtalar joint decreased after surgery, indicating that arthritis at this joint was not necessarily a consequence of ankle arthrodesis but rather a progression of pre-existing degenerative changes. Von Mises stress in the second and third metatarsal bones at the second-peak instant increased to 52 MPa and 34 MPa, respectively, after surgery. These variations can provide indications for outcome assessment of ankle arthrodesis surgery.
Repeatability of the Oxford Foot Model in children with foot deformity.
McCahill, Jennifer; Stebbins, Julie; Koning, Bart; Harlaar, Jaap; Theologis, Tim
2018-03-01
The Oxford Foot Model (OFM) is a multi-segment, kinematic model developed to assess foot motion. It has previously been assessed for repeatability in healthy populations. To determine the OFM's reliability for detecting foot deformity, it is important to know repeatability in pathological conditions. The aim of the study was to assess the repeatability of the OFM in children with foot deformity. Intra-tester repeatability was assessed for 45 children (15 typically developing, 15 hemiplegic, 15 clubfoot). Inter-tester repeatability was assessed in the clubfoot population. The mean absolute differences between testers (clubfoot) and sessions (clubfoot and hemiplegic) were calculated for each of 15 clinically relevant, kinematic variables and compared to typically developing children. Children with clubfoot showed a mean difference between visits of 2.9° and a mean difference between raters of 3.6° Mean absolute differences were within one degree for the intra and inter-rater reliability in 12/15 variables. Hindfoot rotation, forefoot/tibia abduction and forefoot supination were the most variable between testers. Overall the clubfoot data were less variable than the typically developing population. Children with hemiplegia demonstrated slightly higher differences between sessions (mean 4.1°), with the most reliable data in the sagittal plane, and largest differences in the transverse plane. The OFM was designed to measure different types of foot deformity. The results of this study show that it provides repeatable results in children with foot deformity. To be distinguished from measurement artifact, changes in foot kinematics as a result of intervention or natural progression over time must be greater than the repeatability reported here. Copyright © 2018 Elsevier B.V. All rights reserved.
Diabetic foot infections: stepwise medical and surgical management.
Armstrong, David G; Lipsky, Benjamin A
2004-06-01
Foot complications are common among diabetic patients; foot ulcers are among the more serious consequences. These ulcers frequently become infected, with potentially disastrous progression to deeper spaces and tissues. If not treated promptly and appropriately, diabetic foot infections can become incurable or even lead to septic gangrene, which may require foot amputation. Diagnosing infection in a diabetic foot ulcer is based on clinical signs and symptoms of inflammation. Properly culturing an infected lesion can disclose the pathogens and provide their antibiotic susceptibilities. Specimens for culture should be obtained after wound debridement to avoid contamination and optimise identification of pathogens. Staphylococcus aureus is the most common isolate in these infections; the increasing incidence of methicillin-resistant S. aureus over the past two decades has further complicated antibiotic treatment. While chronic infections are often polymicrobial, many acute infections in patients not previously treated with antibiotics are caused by a single pathogen, usually a gram-positive coccus. We offer a stepwise approach to treating diabetic foot infections. Most patients must first be medically stabilised and any metabolic aberrations should be addressed. Antibiotic therapy is not required for uninfected wounds but should be carefully selected for all infected lesions. Initial therapy is usually empirical but may be modified according to the culture and sensitivity results and the patient's clinical response. Surgical intervention is usually required in cases of retained purulence or advancing infection despite optimal medical therapy. Possible additional indications for surgical procedures include incision and drainage of an abscess, debridement of necrotic material, removal of any foreign bodies, arterial revascularisation and, when needed, amputation. Most foot ulcers occur on the plantar surface of the foot, thus requiring a plantar incision for any drainage procedure.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Clark, D. S.; Milovich, J. L.; Hinkel, D. E.
Recent experimental results using the “high foot” pulse shape for inertial confinement fusion ignition experiments on the National Ignition Facility (NIF) [Moses et al., Phys. Plasmas 16, 041006 (2009)] have shown encouraging progress compared to earlier “low foot” experiments. These results strongly suggest that controlling ablation front instability growth can significantly improve implosion performance even in the presence of persistent, large, low-mode distortions. Simultaneously, hydrodynamic growth radiography experiments have confirmed that ablation front instability growth is being modeled fairly well in NIF experiments. It is timely then to combine these two results and ask how current ignition pulse shapes couldmore » be modified to improve one-dimensional implosion performance while maintaining the stability properties demonstrated with the high foot. This paper presents such a survey of pulse shapes intermediate between the low and high foot extremes in search of an intermediate foot optimum. Of the design space surveyed, it is found that a higher picket version of the low foot pulse shape shows the most promise for improved compression without loss of stability.« less