Wu, Lora J; Acebo, Christine; Seifer, Ronald; Carskadon, Mary A
2015-12-01
Quantify the homeostatic and circadian effects on sleepiness and performance of adolescents. Examine age-related changes in homeostatic and circadian regulation of sleepiness and performance by comparing younger and older adolescent groups. Three-week laboratory study including 12 cycles of a 28-h forced desynchrony protocol. Controlled laboratory environment with individual sleep and performance testing rooms and shared common areas. Twenty-seven healthy adolescents including 16 females. Ages ranged from 9.6-15.2 years and participants were split into younger (n = 14 ages 9-12) and older (n = 13 ages 13-15) groups based on median age split of 13.0 years. N/A. Testing occurred every 2 h during scheduled wake periods. Measures included sleep latency during repeated nap opportunities and scores from a computerized neurobehavioral assessment battery including a 10-min psychomotor vigilance task, a digit symbol substitution task, and the Karolinska Sleepiness Scale. Significant main effects of circadian and homeostatic factors were observed, as well as several circadian and homeostatic interaction effects. Age group did not have a significant main effect on sleep and performance data. A significant interaction of circadian phase and age group was found for sleep latency, with younger adolescents showing greater circadian modulation than older teens during the circadian night. Adolescents demonstrated a similar pattern of response to forced desynchrony as reported for adults. Sleepiness and performance were affected by homeostatic and circadian factors, and age group did not interact with homoeostatic and circadian factors for subjective sleepiness and most performance metrics. Younger adolescents had a shorter latency to sleep onset than older during the circadian bin spanning 4 to 8 h after the onset of melatonin secretion. © 2015 Associated Professional Sleep Societies, LLC.
A statistical model of the human core-temperature circadian rhythm
NASA Technical Reports Server (NTRS)
Brown, E. N.; Choe, Y.; Luithardt, H.; Czeisler, C. A.
2000-01-01
We formulate a statistical model of the human core-temperature circadian rhythm in which the circadian signal is modeled as a van der Pol oscillator, the thermoregulatory response is represented as a first-order autoregressive process, and the evoked effect of activity is modeled with a function specific for each circadian protocol. The new model directly links differential equation-based simulation models and harmonic regression analysis methods and permits statistical analysis of both static and dynamical properties of the circadian pacemaker from experimental data. We estimate the model parameters by using numerically efficient maximum likelihood algorithms and analyze human core-temperature data from forced desynchrony, free-run, and constant-routine protocols. By representing explicitly the dynamical effects of ambient light input to the human circadian pacemaker, the new model can estimate with high precision the correct intrinsic period of this oscillator ( approximately 24 h) from both free-run and forced desynchrony studies. Although the van der Pol model approximates well the dynamical features of the circadian pacemaker, the optimal dynamical model of the human biological clock may have a harmonic structure different from that of the van der Pol oscillator.
NASA Technical Reports Server (NTRS)
Van Dongen, Hans P A.; Dinges, David F.
2003-01-01
The two-process model of sleep regulation has been applied successfully to describe, predict, and understand sleep-wake regulation in a variety of experimental protocols such as sleep deprivation and forced desynchrony. A non-linear interaction between the homeostatic and circadian processes was reported when the model was applied to describe alertness and performance data obtained during forced desynchrony. This non-linear interaction could also be due to intrinsic non-linearity in the metrics used to measure alertness and performance, however. Distinguishing these possibilities would be of theoretical interest, but could also have important implications for the design and interpretation of experiments placing sleep at different circadian phases or varying the duration of sleep and/or wakefulness. Although to date no resolution to this controversy has been found, here we show that the issue can be addressed with existing data sets. The interaction between the homeostatic and circadian processes of sleep-wake regulation was investigated using neurobehavioural performance data from a laboratory experiment involving total sleep deprivation. The results provided evidence of an actual non-linear interaction between the homeostatic and circadian processes of sleep-wake regulation for the prediction of waking neurobehavioural performance.
Biphasic effects of alcohol as a function of circadian phase.
Van Reen, Eliza; Rupp, Tracy L; Acebo, Christine; Seifer, Ronald; Carskadon, Mary A
2013-01-01
To assess how alcohol affects multiple sleep latency tests (MSLT) and subjective measures of stimulation/sedation when alcohol is given at different circadian phases. Twenty-seven healthy young adults (age 21-26 yr) were studied. Double-blind placebo and alcohol (vodka tonic targeting 0.05 g% concentration) beverages were each administered three times during the 20-h forced desynchrony protocol. Sleep latency tests and Biphasic Effects of Alcohol Scale (BAES) were administered on each forced desynchrony day. The outcome variables for this study include sleep onset latency (SOL) and stimulation and sedation value (from the BAES). Each outcome variable was associated with the ascending or descending limb of the breath alcohol concentration (BrAC) curve and assigned a circadian phase within a 90° bin. BrAC confirmed targeted maximal levels. Only outcome variables associated with the ascending and descending limb of the alcohol curve were analyzed for this article. Alcohol administered at a circadian time associated with greatest sleepiness showed longer SOL compared with placebo when measured on the ascending limb of the BrAC curve. We also found longer SOL with alcohol on the ascending limb of the BrAC curve in a circadian bin that favors greatest alertness. We observed shorter SOLs on the descending limb of the BrAC curve, but with no circadian phase interaction. The subjective data were partially consistent with the objective data. The physiologic findings in this study support the biphasic stimulating and sedating properties of alcohol, but limit the effect to specific circadian times.
Biphasic Effects of Alcohol as a Function of Circadian Phase
Van Reen, Eliza; Rupp, Tracy L.; Acebo, Christine; Seifer, Ronald; Carskadon, Mary A.
2013-01-01
Study Objectives: To assess how alcohol affects multiple sleep latency tests (MSLT) and subjective measures of stimulation/sedation when alcohol is given at different circadian phases. Participants: Twenty-seven healthy young adults (age 21-26 yr) were studied. Design: Double-blind placebo and alcohol (vodka tonic targeting 0.05 g% concentration) beverages were each administered three times during the 20-h forced desynchrony protocol. Sleep latency tests and Biphasic Effects of Alcohol Scale (BAES) were administered on each forced desynchrony day. The outcome variables for this study include sleep onset latency (SOL) and stimulation and sedation value (from the BAES). Each outcome variable was associated with the ascending or descending limb of the breath alcohol concentration (BrAC) curve and assigned a circadian phase within a 90° bin. Measurements and Results: BrAC confirmed targeted maximal levels. Only outcome variables associated with the ascending and descending limb of the alcohol curve were analyzed for this article. Alcohol administered at a circadian time associated with greatest sleepiness showed longer SOL compared with placebo when measured on the ascending limb of the BrAC curve. We also found longer SOL with alcohol on the ascending limb of the BrAC curve in a circadian bin that favors greatest alertness. We observed shorter SOLs on the descending limb of the BrAC curve, but with no circadian phase interaction. The subjective data were partially consistent with the objective data. Conclusions: The physiologic findings in this study support the biphasic stimulating and sedating properties of alcohol, but limit the effect to specific circadian times. Citation: Van Reen E; Rupp TL; Acebo C; Seifer R; Carskadon MA. Biphasic effects of alcohol as a function of circadian phase. SLEEP 2013;36(1):137-145. PMID:23288980
Hours of Boredom, Moments of Terror: Temporal Desynchrony in Military and Security Force Operations
2010-10-01
Administrative Science Quarterly 24 (1979), 285–306. 31 Robert A. Karasek and Tores Theorell , Healthy Work: Stress, Productivity and the...first symptoms of incipient failure. 30 Robert A. Karasek , “Job Demands, Job Decision Latitude and Mental Strain: Implications for Job Redesign
Fitzgerald, G A; Yang, G; Paschos, G K; Liang, X; Skarke, C
2015-09-01
Molecular clockworks knit together diverse biological networks and compelling evidence from model systems infers their importance in metabolism, immunological and cardiovascular function. Despite this and the diurnal variation in many aspects of human physiology and the phenotypic expression of disease, our understanding of the role and importance of clock function and dysfunction in humans is modest. There are tantalizing hints of connection across the translational divide and some correlative evidence of gene variation and human disease but most of what we know derives from forced desynchrony protocols in controlled environments. We now have the ability to monitor quantitatively ex vivo or in vivo the genome, metabolome, proteome and microbiome of humans in the wild. Combining this capability, with the power of mobile telephony and the evolution of remote sensing, affords a new opportunity for deep phenotyping, including the characterization of diurnal behaviour and the assessment of the impact of the clock on approved drug function. © 2015 John Wiley & Sons Ltd.
Relationship between alertness, performance, and body temperature in humans.
Wright, Kenneth P; Hull, Joseph T; Czeisler, Charles A
2002-12-01
Body temperature has been reported to influence human performance. Performance is reported to be better when body temperature is high/near its circadian peak and worse when body temperature is low/near its circadian minimum. We assessed whether this relationship between performance and body temperature reflects the regulation of both the internal biological timekeeping system and/or the influence of body temperature on performance independent of circadian phase. Fourteen subjects participated in a forced desynchrony protocol allowing assessment of the relationship between body temperature and performance while controlling for circadian phase and hours awake. Most neurobehavioral measures varied as a function of internal biological time and duration of wakefulness. A number of performance measures were better when body temperature was elevated, including working memory, subjective alertness, visual attention, and the slowest 10% of reaction times. These findings demonstrate that an increased body temperature, associated with and independent of internal biological time, is correlated with improved performance and alertness. These results support the hypothesis that body temperature modulates neurobehavioral function in humans.
Relationship between alertness, performance, and body temperature in humans
NASA Technical Reports Server (NTRS)
Wright, Kenneth P Jr; Hull, Joseph T.; Czeisler, Charles A.
2002-01-01
Body temperature has been reported to influence human performance. Performance is reported to be better when body temperature is high/near its circadian peak and worse when body temperature is low/near its circadian minimum. We assessed whether this relationship between performance and body temperature reflects the regulation of both the internal biological timekeeping system and/or the influence of body temperature on performance independent of circadian phase. Fourteen subjects participated in a forced desynchrony protocol allowing assessment of the relationship between body temperature and performance while controlling for circadian phase and hours awake. Most neurobehavioral measures varied as a function of internal biological time and duration of wakefulness. A number of performance measures were better when body temperature was elevated, including working memory, subjective alertness, visual attention, and the slowest 10% of reaction times. These findings demonstrate that an increased body temperature, associated with and independent of internal biological time, is correlated with improved performance and alertness. These results support the hypothesis that body temperature modulates neurobehavioral function in humans.
Nonentrained circadian rhythms of melatonin in submariners scheduled to an 18-hour day.
Kelly, T L; Neri, D F; Grill, J T; Ryman, D; Hunt, P D; Dijk, D J; Shanahan, T L; Czeisler, C A
1999-06-01
The human circadian timing system has previously been shown to free run with a period slightly longer than 24 h in subjects living in the laboratory under conditions of forced desynchrony. In forced desynchrony, subjects are shielded from bright light and periodic time cues and are required to live on a day length outside the range of circadian entrainment. The work schedule used for most personnel aboard American submarines is 6 h on duty alternating with 12 h off duty. This imposed 18-h cycle is too short for human circadian synchronization, especially given that there is no bright-light exposure aboard submarines. However, crew members are exposed to 24-h stimuli that could mediate synchronization, such as clocks and social contacts with personnel who are living on a 24-h schedule. The authors investigated circadian rhythms of salivary melatonin in 20 crew members during a prolonged voyage on a Trident nuclear submarine. The authors found that in crew members living on the 18-h duty cycle, the endogenous rhythm of melatonin showed an average period of 24.35 h (n = 12, SD = 0.18 h). These data indicate that social contacts and knowledge of clock time are insufficient for entrainment to a 24-h period in personnel living by an 18-h rest-activity cycle aboard a submarine.
Allen, Kristy Benoit; Allen, Ben; Austin, Kristin E.; Waldron, Jonathan C.; Ollendick, Thomas H.
2015-01-01
The tripartite model of fear posits that the fear response entails three loosely coupled components: subjective distress, behavioral avoidance, and physiological arousal. The concept of synchrony vs. desynchrony describes the degree to which changes in the activation of these components vary together (synchrony), independently, or inversely (both forms of desynchrony) over time. The present study assessed synchronony-desynchrony and its relationship to treatment outcome in a sample of 98 children with specific phobias both prior to and 1 week after receiving one-session treatment, a 3 hour cognitive-behavioral intervention. The results suggest an overall pattern of desynchronous change whereby youth improved on behavioral avoidance and subjective distress following treatment, but their level of cardiovascular reactivity remained stable. However, we found evidence that synchronous change on the behavioral avoidance and subjective distress components was related to better treatment outcome, whereas desynchronous change on these components was related to poorer treatment outcome. These findings suggest that a fuller understanding of the three response systems and their interrelations in phobic youth may assist us in the assessment and treatment of these disorders, potentially leading to a more person-centered approach and eventually to enhanced treatment outcomes. PMID:26073497
Circadian rhythms and fractal fluctuations in forearm motion
NASA Astrophysics Data System (ADS)
Hu, Kun; Hilton, Michael F.
2005-03-01
Recent studies have shown that the circadian pacemaker --- an internal body clock located in the brain which is normally synchronized with the sleep/wake behavioral cycles --- influences key physiologic functions such as the body temperature, hormone secretion and heart rate. Surprisingly, no previous studies have investigated whether the circadian pacemaker impacts human motor activity --- a fundamental physiologic function. We investigate high-frequency actigraph recordings of forearm motion from a group of young and healthy subjects during a forced desynchrony protocol which allows to decouple the sleep/wake cycles from the endogenous circadian cycle while controlling scheduled behaviors. We investigate both static properties (mean value, standard deviation), dynamical characteristics (long-range correlations), and nonlinear features (magnitude and Fourier-phase correlations) in the fluctuations of forearm acceleration across different circadian phases. We demonstrate that while the static properties exhibit significant circadian rhythms with a broad peak in the afternoon, the dynamical and nonlinear characteristics remain invariant with circadian phase. This finding suggests an intrinsic multi-scale dynamic regulation of forearm motion the mechanism of which is not influenced by the circadian pacemaker, thus suggesting that increased cardiac risk in the early morning hours is not related to circadian-mediated influences on motor activity.
Benoit Allen, Kristy; Allen, Ben; Austin, Kristin E; Waldron, Jonathan C; Ollendick, Thomas H
2015-08-01
The tripartite model of fear posits that the fear response entails three loosely coupled components: subjective distress, behavioral avoidance, and physiological arousal. The concept of synchrony vs. desynchrony describes the degree to which changes in the activation of these components vary together (synchrony), independently, or inversely (both forms of desynchrony) over time. The present study assessed synchrony-desynchrony and its relationship to treatment outcome in a sample of 98 children with specific phobias both prior to and 1 week after receiving one-session treatment, a 3 h cognitive-behavioral intervention. The results suggest an overall pattern of desynchronous change whereby youth improved on behavioral avoidance and subjective distress following treatment, but their level of cardiovascular reactivity remained stable. However, we found evidence that synchronous change on the behavioral avoidance and subjective distress components was related to better treatment outcome, whereas desynchronous change on these components was related to poorer treatment outcome. These findings suggest that a fuller understanding of the three response systems and their interrelations in phobic youth may assist us in the assessment and treatment of these disorders, potentially leading to a more person-centered approach and eventually to enhanced treatment outcomes. Copyright © 2015 Elsevier Ltd. All rights reserved.
Misalignment with the external light environment drives metabolic and cardiac dysfunction.
West, Alexander C; Smith, Laura; Ray, David W; Loudon, Andrew S I; Brown, Timothy M; Bechtold, David A
2017-09-12
Most organisms use internal biological clocks to match behavioural and physiological processes to specific phases of the day-night cycle. Central to this is the synchronisation of internal processes across multiple organ systems. Environmental desynchrony (e.g. shift work) profoundly impacts human health, increasing cardiovascular disease and diabetes risk, yet the underlying mechanisms remain unclear. Here, we characterise the impact of desynchrony between the internal clock and the external light-dark (LD) cycle on mammalian physiology. We reveal that even under stable LD environments, phase misalignment has a profound effect, with decreased metabolic efficiency and disrupted cardiac function including prolonged QT interval duration. Importantly, physiological dysfunction is not driven by disrupted core clock function, nor by an internal desynchrony between organs, but rather the altered phase relationship between the internal clockwork and the external environment. We suggest phase misalignment as a major driver of pathologies associated with shift work, chronotype and social jetlag.The misalignment between internal circadian rhythm and the day-night cycle can be caused by genetic, behavioural and environmental factors, and may have a profound impact on human physiology. Here West et al. show that desynchrony between the internal clock and the external environment alter metabolic parameters and cardiac function in mice.
NASA Technical Reports Server (NTRS)
Ruger, M.; Scheer, F. A. J.; Barger, L. K.; Lockley, S. W.; Wang, W.; Johnston, S. L. III; Crucian, B.; Shea, A. S.
2011-01-01
Microgravity is a physiologically challenging state even when at rest. Astronauts experience additional physical and mental stresses, such as prolonged exertion, sleep loss and circadian misalignment, that could impact cardiovascular function. The main goals of this four year NASA project are to characterize the independent and synergistic effects on cardiovascular and immune function of: (1) circadian misalignment; (2) sleep loss; and (3) varied physical and mental stressors, mimicking some of the synergistic stressors experienced by astronauts. Sixteen healthy volunteers, aged 35-55 years, will be studied with standardized behavioral stressors occurring across all circadian phases, both with and without accruing sleep loss, achieved via two 11-day "forced desynchrony" protocols performed in each subject (randomized, within-subject design), where wake periods are advanced 4-h each "day" (i.e. recurring 20-h "days"). One protocol permits 8.33 h sleep opportunity per 20-h "day" (=10 h sleep per 24-h), and the other permits 5 h sleep per 20-h "day" (=6 h sleep per 24-h; matching the reported sleep duration of astronauts). In both protocols, subjects will perform a standardized stress battery including a cognitively challenging task; bicycle exercise, and passive 60deg head up tilt. Outcome variables include blood pressure, heart rate, arrhythmia frequency, cardiac vagal tone (from heart rate variability), sympathetic activity (catecholamines), and endothelial function. Additional measures of cardiac function (echocardiography), responses to a passive 80deg head up tilt, maximal oxygen uptake, and immune function will be assessed at the beginning and at the end of each protocol (i.e., without and with sleep loss, and before and after circadian misalignment). We hope to identify the relative impact on cardiovascular risk markers of varied behavioural stressors while subjects experience circadian misalignment and sleep loss, mimicking some of the synergistic stressors experienced by astronauts. Supported by NASANNX1 OAR 1 OG.
Prediction of Cognitive Performance and Subjective Sleepiness Using a Model of Arousal Dynamics.
Postnova, Svetlana; Lockley, Steven W; Robinson, Peter A
2018-04-01
A model of arousal dynamics is applied to predict objective performance and subjective sleepiness measures, including lapses and reaction time on a visual Performance Vigilance Test (vPVT), performance on a mathematical addition task (ADD), and the Karolinska Sleepiness Scale (KSS). The arousal dynamics model is comprised of a physiologically based flip-flop switch between the wake- and sleep-active neuronal populations and a dynamic circadian oscillator, thus allowing prediction of sleep propensity. Published group-level experimental constant routine (CR) and forced desynchrony (FD) data are used to calibrate the model to predict performance and sleepiness. Only the studies using dim light (<15 lux) during alertness measurements and controlling for sleep and entrainment before the start of the protocol are selected for modeling. This is done to avoid the direct alerting effects of light and effects of prior sleep debt and circadian misalignment on the data. The results show that linear combination of circadian and homeostatic drives is sufficient to predict dynamics of a variety of sleepiness and performance measures during CR and FD protocols, with sleep-wake cycles ranging from 20 to 42.85 h and a 2:1 wake-to-sleep ratio. New metrics relating model outputs to performance and sleepiness data are developed and tested against group average outcomes from 7 (vPVT lapses), 5 (ADD), and 8 (KSS) experimental protocols, showing good quantitative and qualitative agreement with the data (root mean squared error of 0.38, 0.19, and 0.35, respectively). The weights of the homeostatic and circadian effects are found to be different between the measures, with KSS having stronger homeostatic influence compared with the objective measures of performance. Using FD data in addition to CR data allows us to challenge the model in conditions of both acute sleep deprivation and structured circadian misalignment, ensuring that the role of the circadian and homeostatic drives in performance is properly captured.
Chronobiology and mood disorders
Wirz-Justice, Anna
2003-01-01
The clinical observations of diurnal variation of mood and early morning awakening in depression have been incorporated into established diagnostic systems, as has the seasonal modifier defining winter depression (seasonal affective disorder, SAD). Many circadian rhythms measured in depressive patients are abnormal: earlier in timing, diminished in amplitude, or of greater variability. Whether these disturbances are of etiological significance for the role of circadian rhythms in mood disorders, or a consequence of altered behavior can only be dissected out with stringent protocols (eg, constant routine or forced desynchrony). These protocols quantify contributions of the circadian pacemaker and a homeostatic sleep process impacting on mood, energy, appetite, and sleep. Future studies will elucidate any allelic mutations in “circadian clock” –related or “sleep”-related genes in depression. With respect to treatment, antidepressants and mood stabilizers have no consistent effect on circadian rhythmicity. The most rapid antidepressant modality known so far is nonpharmacological: total or partial sleep deprivation in the second half of the night. The disadvantage of sleep deprivation, that most patients relapse after recovery sleep, can be prevented by coadministration of lithium, pindolol, serotonin (5-HT) reuptake inhibitors, bright light, or a subsequent phase-advance procedure. Phase advance of the sleep-wake cycle alone also has rapid effects on depressed mood, which lasts longer than sleep deprivation. Light is the treatment of choice for SAD and may prove to be useful for nonseasonal depression, alone or as an adjunct to medication. Chronobiological concepts emphasize the important role of zeitgebers to stabilize phase, light being the most important, but dark (and rest) periods, regularity of social schedules and meal times, and use of melatonin or its analogues should also be considered. Advances in chronobiology continue to contribute novel treatments for affective disorders. PMID:22033593
Paech, Gemma M.; Ferguson, Sally A.; Sargent, Charli; Kennaway, David J.; Roach, Gregory D.
2012-01-01
Study Objectives: To investigate the relative contributions of the homeostatic and circadian processes on sleep regulation under conditions of severe sleep restriction. Design: The 13-day laboratory based study consisted of 3 × 24-h baseline days (8 h sleep opportunity, 16 h wake) followed by 7 × 28-h forced desynchrony days (4.7 h sleep opportunity, 23.3 h wake). Setting: The study was conducted in a time isolation unit at the Centre for Sleep Research, University of South Australia. Participants: Fourteen healthy, nonsmoking males, aged 21.8 ± 3.8 (mean ± SD) years participated in the study. Interventions: N/A Measurements: Sleep was measured using standard polysomnography. Core body temperature (CBT) was recorded continuously using a rectal thermistor. Each epoch of sleep was assigned a circadian phase based on the CBT data (6 × 60-degree bins) and an elapsed time into sleep episode (2 × 140-min intervals). Results: The percentage of SWS decreased with elapsed time into the sleep episode. However, no change in the percentage of REM sleep was observed with sleep progression. Whilst there was a circadian modulation of REM sleep, the amplitude of the circadian variation was smaller than expected. Sleep efficiency remained high throughout the sleep episode and across all circadian phases. Conclusions: Previous forced desynchrony studies have demonstrated a strong circadian influence on sleep, in the absence of sleep restriction. The current study suggests that in the presence of high homeostatic pressure, the circadian modulation of sleep, in particular sleep efficiency and to a lesser extent, REM sleep, are reduced. Citation: Paech GM; Ferguson SA; Sargent C; Kennaway DJ; Roach GD. The relative contributions of the homeostatic and circadian processes to sleep regulation under conditions of severe sleep restriction. SLEEP 2012;35(7):941-948. PMID:22754040
Internal desynchronization in a model of night-work by forced activity in rats.
Salgado-Delgado, R; Angeles-Castellanos, M; Buijs, M R; Escobar, C
2008-06-26
Individuals engaged in shift- or night-work show disturbed diurnal rhythms, out of phase with temporal signals associated to the light/dark (LD) cycle, resulting in internal desynchronization. The mechanisms underlying internal desynchrony have been mainly investigated in experimental animals with protocols that induce phase shifts of the LD cycle and thus modify the activity of the suprachiasmatic nucleus (SCN). In this study we developed an animal model of night-work in which the light-day cycle remained stable and rats were required to be active in a rotating wheel for 8 h daily during their sleeping phase (W-SP). This group was compared with rats that were working in the wheel during their activity phase (W-AP) and with undisturbed rats (C). We provide evidence that forced activity during the sleeping phase (W-SP group) alters not only activity, but also the temporal pattern of food intake. In consequence W-SP rats showed a loss of glucose rhythmicity and a reversed rhythm of triacylglycerols. In contrast W-AP rats did not show such changes and exhibited metabolic rhythms similar to those of the controls. The three groups exhibited the nocturnal corticosterone increase, in addition the W-SP and W-AP groups showed increase of plasma corticosterone associated with the start of the working session. Forced activity during the sleep phase did not modify SCN activity characterized by the temporal patterns of PER1 and PER2 proteins, which remained in phase with the LD cycle. These observations indicate that a working regimen during the sleeping period elicits internal desynchronization in which activity combined with feeding uncouples metabolic functions from the biological clock which remains fixed to the LD cycle. The present data suggest that in the night worker the combination of work and eating during working hours may be the cause of internal desynchronization.
Sleep inertia, sleep homeostatic, and circadian influences on higher-order cognitive functions
Ronda, Joseph M.; Czeisler, Charles A.; Wright, Kenneth P.
2016-01-01
Summary Sleep inertia, sleep homeostatic, and circadian processes modulate cognition, including reaction time, memory, mood, and alertness. How these processes influence higher-order cognitive functions is not well known. Six participants completed a 73-daylong study that included two 14-daylong 28h forced desynchrony protocols, to examine separate and interacting influences of sleep inertia, sleep homeostasis, and circadian phase on higher-order cognitive functions of inhibitory control and selective visual attention. Cognitive performance for most measures was impaired immediately after scheduled awakening and improved over the first ~2-4h of wakefulness (sleep inertia); worsened thereafter until scheduled bedtime (sleep homeostasis); and was worst at ~60° and best at ~240° (circadian modulation, with worst and best phases corresponding to ~9AM and ~9PM respectively, in individuals with a habitual waketime of 7AM). The relative influences of sleep inertia, sleep homeostasis, and circadian phase depended on the specific higher-order cognitive function task examined. Inhibitory control appeared to be modulated most strongly by circadian phase, whereas selective visual attention for a spatial-configuration search task was modulated most strongly by sleep inertia. These findings demonstrate that some higher-order cognitive processes are differentially sensitive to different sleep-wake regulatory processes. Differential modulation of cognitive functions by different sleep-wake regulatory processes has important implications for understanding mechanisms contributing to performance impairments during adverse circadian phases, sleep deprivation, and/or upon awakening from sleep. PMID:25773686
Circadian clocks, feeding time, and metabolic homeostasis
Paschos, Georgios K.
2015-01-01
Metabolic processes exhibit diurnal variation from cyanobacteria to humans. The circadian clock is thought to have evolved as a time keeping system for the cell to optimize the timing of metabolic events according to physiological needs and environmental conditions. Circadian rhythms temporally separate incompatible cellular processes and optimize cellular and organismal fitness. A modern 24 h lifestyle can run at odds with the circadian rhythm dictated by our molecular clocks and create desynchrony between internal and external timing. It has been suggested that this desynchrony compromises metabolic homeostasis and may promote the development of obesity (Morris et al., 2012). Here we review the evidence supporting the association between circadian misalignment and metabolic homeostasis and discuss the role of feeding time. PMID:26082718
Controlling chaos with localized heterogeneous forces in oscillator chains.
Chacón, Ricardo
2006-10-01
The effects of decreasing the impulse transmitted by localized periodic pulses on the chaotic behavior of homogeneous chains of coupled nonlinear oscillators are studied. It is assumed that when the oscillators are driven synchronously, i.e., all driving pulses transmit the same impulse, the chains display chaotic dynamics. It is shown that decreasing the impulse transmitted by the pulses of the two free end oscillators results in regularization with the whole array exhibiting frequency synchronization, irrespective of the chain size. A maximum level of amplitude desynchrony as the pulses of the two end oscillators narrow is typically found, which is explained as the result of two competing universal mechanisms: desynchronization induced by localized heterogeneous pulses and oscillation death of the complete chain induced by drastic decreasing of the impulse transmitted by such localized pulses. These findings demonstrate that decreasing the impulse transmitted by localized external forces can suppress chaos and lead to frequency-locked states in networks of dissipative systems.
Sex differences in the circadian regulation of sleep and waking cognition in humans.
Santhi, Nayantara; Lazar, Alpar S; McCabe, Patrick J; Lo, June C; Groeger, John A; Dijk, Derk-Jan
2016-05-10
The sleep-wake cycle and circadian rhythmicity both contribute to brain function, but whether this contribution differs between men and women and how it varies across cognitive domains and subjective dimensions has not been established. We examined the circadian and sleep-wake-dependent regulation of cognition in 16 men and 18 women in a forced desynchrony protocol and quantified the separate contributions of circadian phase, prior sleep, and elapsed time awake on cognition and sleep. The largest circadian effects were observed for reported sleepiness, mood, and reported effort; the effects on working memory and temporal processing were smaller. Although these effects were seen in both men and women, there were quantitative differences. The amplitude of the circadian modulation was larger in women in 11 of 39 performance measures so that their performance was more impaired in the early morning hours. Principal components analysis of the performance measures yielded three factors, accuracy, effort, and speed, which reflect core performance characteristics in a range of cognitive tasks and therefore are likely to be important for everyday performance. The largest circadian modulation was observed for effort, whereas accuracy exhibited the largest sex difference in circadian modulation. The sex differences in the circadian modulation of cognition could not be explained by sex differences in the circadian amplitude of plasma melatonin and electroencephalographic slow-wave activity. These data establish the impact of circadian rhythmicity and sex on waking cognition and have implications for understanding the regulation of brain function, cognition, and affect in shift-work, jetlag, and aging.
Sleep inertia, sleep homeostatic and circadian influences on higher-order cognitive functions.
Burke, Tina M; Scheer, Frank A J L; Ronda, Joseph M; Czeisler, Charles A; Wright, Kenneth P
2015-08-01
Sleep inertia, sleep homeostatic and circadian processes modulate cognition, including reaction time, memory, mood and alertness. How these processes influence higher-order cognitive functions is not well known. Six participants completed a 73-day-long study that included two 14-day-long 28-h forced desynchrony protocols to examine separate and interacting influences of sleep inertia, sleep homeostasis and circadian phase on higher-order cognitive functions of inhibitory control and selective visual attention. Cognitive performance for most measures was impaired immediately after scheduled awakening and improved during the first ~2-4 h of wakefulness (decreasing sleep inertia); worsened thereafter until scheduled bedtime (increasing sleep homeostasis); and was worst at ~60° and best at ~240° (circadian modulation, with worst and best phases corresponding to ~09:00 and ~21:00 hours, respectively, in individuals with a habitual wake time of 07:00 hours). The relative influences of sleep inertia, sleep homeostasis and circadian phase depended on the specific higher-order cognitive function task examined. Inhibitory control appeared to be modulated most strongly by circadian phase, whereas selective visual attention for a spatial-configuration search task was modulated most strongly by sleep inertia. These findings demonstrate that some higher-order cognitive processes are differentially sensitive to different sleep-wake regulatory processes. Differential modulation of cognitive functions by different sleep-wake regulatory processes has important implications for understanding mechanisms contributing to performance impairments during adverse circadian phases, sleep deprivation and/or upon awakening from sleep. © 2015 European Sleep Research Society.
Sex differences in the circadian regulation of sleep and waking cognition in humans
Santhi, Nayantara; Lazar, Alpar S.; McCabe, Patrick J.; Lo, June C.; Groeger, John A.; Dijk, Derk-Jan
2016-01-01
The sleep–wake cycle and circadian rhythmicity both contribute to brain function, but whether this contribution differs between men and women and how it varies across cognitive domains and subjective dimensions has not been established. We examined the circadian and sleep–wake-dependent regulation of cognition in 16 men and 18 women in a forced desynchrony protocol and quantified the separate contributions of circadian phase, prior sleep, and elapsed time awake on cognition and sleep. The largest circadian effects were observed for reported sleepiness, mood, and reported effort; the effects on working memory and temporal processing were smaller. Although these effects were seen in both men and women, there were quantitative differences. The amplitude of the circadian modulation was larger in women in 11 of 39 performance measures so that their performance was more impaired in the early morning hours. Principal components analysis of the performance measures yielded three factors, accuracy, effort, and speed, which reflect core performance characteristics in a range of cognitive tasks and therefore are likely to be important for everyday performance. The largest circadian modulation was observed for effort, whereas accuracy exhibited the largest sex difference in circadian modulation. The sex differences in the circadian modulation of cognition could not be explained by sex differences in the circadian amplitude of plasma melatonin and electroencephalographic slow-wave activity. These data establish the impact of circadian rhythmicity and sex on waking cognition and have implications for understanding the regulation of brain function, cognition, and affect in shift-work, jetlag, and aging. PMID:27091961
Circadian regulation of slow waves in human sleep: Topographical aspects
Lazar, Alpar S.; Lazar, Zsolt I.; Dijk, Derk-Jan
2015-01-01
Slow waves (SWs, 0.5–4 Hz) in field potentials during sleep reflect synchronized alternations between bursts of action potentials and periods of membrane hyperpolarization of cortical neurons. SWs decline during sleep and this is thought to be related to a reduction of synaptic strength in cortical networks and to be central to sleep's role in maintaining brain function. A central assumption in current concepts of sleep function is that SWs during sleep, and associated recovery processes, are independent of circadian rhythmicity. We tested this hypothesis by quantifying all SWs from 12 EEG derivations in 34 participants in whom 231 sleep periods were scheduled across the circadian cycle in a 10-day forced-desynchrony protocol which allowed estimation of the separate circadian and sleep-dependent modulation of SWs. Circadian rhythmicity significantly modulated the incidence, amplitude, frequency and the slope of the SWs such that the peaks of the circadian rhythms in these slow-wave parameters were located during the biological day. Topographical analyses demonstrated that the sleep-dependent modulation of SW characteristics was most prominent in frontal brain areas whereas the circadian effect was similar to or greater than the sleep-dependent modulation over the central and posterior brain regions. The data demonstrate that circadian rhythmicity directly modulates characteristics of SWs thought to be related to synaptic plasticity and that this modulation depends on topography. These findings have implications for the understanding of local sleep regulation and conditions such as ageing, depression, and neurodegeneration which are associated with changes in SWs, neural plasticity and circadian rhythmicity. PMID:25979664
Star-coupled Hindmarsh-Rose neural network with chemical synapses
NASA Astrophysics Data System (ADS)
Usha, K.; Subha, P. A.
We analyze the patterns like synchrony, desynchrony, and Drum head mode in a network of Hindmarsh-Rose (HR) neurons interacting via chemical synapse in unidirectional and bidirectional star topology. A two-coupled system has been studied for synchronization by varying the coupling strength and the parameter describing the activation and inactivation of the fast ion channel. The transverse Lyapunov exponent spectrum is plotted to observe the point of transition from desynchrony to synchrony. The synchronized, desynchronized, and drum head mode regions are observed when the neurons are connected in unidirectional and bidirectional coupling configurations. A detailed analysis about the time evolution of membrane potential corresponding to each region is presented. The annihilation of synchronized region and the expansion of drum head mode region in bidirectional coupling is discussed using parameter space. Our work provides finer insight into the existence and stability of Drum head mode and is useful for designing communication networks.
Ma, Hui-Ing; Hwang, Wen-Juh; Wang, Ching-Yi; Fang, Jing-Jing; Leong, Iat-Fai; Wang, Tsui-Ying
2012-10-01
We used a trunk-assisted prehension task to examine the effect of task (reaching for stationary vs. moving targets) and environmental constraints (virtual reality [VR] vs. physical reality) on the temporal control of trunk and arm motions in people with Parkinson's disease (PD). Twenty-four participants with PD and 24 age-matched controls reached for and grasped a ball that was either stationary or moving along a ramp 120% of arm length away. In a similar VR task, participants reached for a virtual ball that was either stationary or moving. Movement speed was measured as trunk and arm movement times (MTs); trunk-arm coordination was measured as onset interval and offset interval between trunk and arm motions, as well as a summarized index-desynchrony score. In both VR and physical reality, the PD group had longer trunk and arm MTs than the control group when reaching for stationary balls (p<.001). When reaching for moving balls in VR and physical reality, however, the PD group had lower trunk and arm MTs, onset intervals, and desynchrony scores (p<.001). For the PD group, VR induced shorter trunk MTs, shorter offset intervals, and lower desynchrony scores than did physical reality when reaching for moving balls (p<.001). These findings suggest that using real moving targets in trunk-assisted prehension tasks improves the speed and synchronization of trunk and arm motions in people with PD, and that using virtual moving targets may induce a movement termination strategy different from that used in physical reality. Copyright © 2012 Elsevier B.V. All rights reserved.
Psychophysiological Outcome of Behavioral and Pharmacological Treatments of Agoraphobia.
ERIC Educational Resources Information Center
Michelson, Larry; Mavissakalian, Matig
1985-01-01
Examined relative and combined effectiveness of behavior therapy and pharmacotherapy in 62 severe, chronic agoraphobics. Identified differential temporal response and treatment patterns across psychophysiological domains. Synchrony/desynchrony phenomena yielded significant findings with regard to process and clinical outcome status. Exploratory…
Human phase response curve to intermittent blue light using a commercially available device
Revell, Victoria L; Molina, Thomas A; Eastman, Charmane I
2012-01-01
Light shifts the timing of the circadian clock according to a phase response curve (PRC). To date, all human light PRCs have been to long durations of bright white light. However, melanopsin, the primary photopigment for the circadian system, is most sensitive to short wavelength blue light. Therefore, to optimise light treatment it is important to generate a blue light PRC. We used a small, commercially available blue LED light box, screen size 11.2 × 6.6 cm at ∼50 cm, ∼200 μW cm−2, ∼185 lux. Subjects participated in two 5 day laboratory sessions 1 week apart. Each session consisted of circadian phase assessments to obtain melatonin profiles before and after 3 days of free-running through an ultradian light–dark cycle (2.5 h wake in dim light, 1.5 h sleep in the dark), forced desynchrony protocol. During one session subjects received intermittent blue light (three 30 min pulses over 2 h) once a day for the 3 days of free-running, and in the other session (control) they remained in dim room light, counterbalanced. The time of blue light was varied among subjects to cover the entire 24 h day. For each individual, the phase shift to blue light was corrected for the free-run determined during the control session. The blue light PRC had a broad advance region starting in the morning and extending through the afternoon. The delay region started a few hours before bedtime and extended through the night. This is the first PRC to be constructed to blue light and to a stimulus that could be used in the real world. PMID:22753544
NASA Technical Reports Server (NTRS)
Dijk, D. J.
1999-01-01
In humans, EEG power spectra in REM and NREM sleep, as well as characteristics of sleep spindles such as their duration, amplitude, frequency and incidence, vary with circadian phase. Recently it has been hypothesized that circadian variations in EEG spectra in humans are caused by variations in brain or body temperature and may not represent phenomena relevant to sleep regulatory processes. To test this directly, a further analysis of EEG power spectra - collected in a forced desynchrony protocol in which sleep episodes were scheduled to a 28-h period while the rhythms of body temperature and plasma melatonin were oscillating at their near 24-h period - was carried out. EEG power spectra were computed for NREM and REM sleep occurring between 90-120 and 270-300 degrees of the circadian melatonin rhythm, i.e. just after the clearance of melatonin from plasma in the 'morning' and just after the 'evening' increase in melatonin secretion. Average body temperatures during scheduled sleep at these two circadian phases were identical (36.72 degrees C). Despite identical body temperatures, the power spectra in NREM sleep were very different at these two circadian phases. EEG activity in the low frequency spindle range was significantly and markedly enhanced after the evening increase in plasma melatonin as compared to the morning phase. For REM sleep, significant differences in power spectra during these two circadian phases, in particular in the alpha range, were also observed. The results confirm that EEG power spectra in NREM and REM sleep vary with circadian phase, suggesting that the direct contribution of temperature to the circadian variation in EEG power spectra is absent or only minor, and are at variance with the hypothesis that circadian variations in EEG power spectra are caused by variations in temperature.
Human phase response curve to intermittent blue light using a commercially available device.
Revell, Victoria L; Molina, Thomas A; Eastman, Charmane I
2012-10-01
Light shifts the timing of the circadian clock according to a phase response curve (PRC). To date, all human light PRCs have been to long durations of bright white light. However, melanopsin, the primary photopigment for the circadian system, is most sensitive to short wavelength blue light. Therefore, to optimise light treatment it is important to generate a blue light PRC.We used a small, commercially available blue LED light box, screen size 11.2 × 6.6 cm at ∼50 cm, ∼200 μW cm(−2), ∼185 lux. Subjects participated in two 5 day laboratory sessions 1 week apart. Each session consisted of circadian phase assessments to obtain melatonin profiles before and after 3 days of free-running through an ultradian light–dark cycle (2.5 h wake in dim light, 1.5 h sleep in the dark), forced desynchrony protocol. During one session subjects received intermittent blue light (three 30 min pulses over 2 h) once a day for the 3 days of free-running, and in the other session (control) they remained in dim room light, counterbalanced. The time of blue light was varied among subjects to cover the entire 24 h day. For each individual, the phase shift to blue light was corrected for the free-run determined during the control session. The blue light PRC had a broad advance region starting in the morning and extending through the afternoon. The delay region started a few hours before bedtime and extended through the night. This is the first PRC to be constructed to blue light and to a stimulus that could be used in the real world.
Collective Dynamics of Oscillator Networks: Why do we suffer from heavy jet lag?
NASA Astrophysics Data System (ADS)
Kori, Hiroshi
The circadian rhythm of the entire body in mammals is orchestrated by a small tissue in the brain called the suprachiamatic nucleus (SCN). The SCN consists of a population of neurons, each of which exhibit circadian (i.e., approximately 24 h) gene expression. Neurons form a complex network and interact with each other using various types of neurotransmitters. The rhythmic gene expressions of individual cells in the SCN synchronize through such interaction. Jet-lag symptoms arise from temporal mismatch between the internal circadian clock orchestrated by the SCN and external solar time. It may take about one week or even longer to recover from jet lag after a long-distance trip. We recently found that recovery from jet lag is considerably accelerated in the knocked-out (KO) mice lacking the receptors of a certain neurotransmitter in the SCN. Importantly, all other properties of mice including sleep-awake rhythms and breeding seem to be intact. Only the response to the jet lag changes. It was also found that after a few days of jet lag, cells in the SCN desynchronize in the wild type (WT) mice, whereas they do not in KO mice. This desynchrony might be a main reason for heavy jet lag symptoms. To understand the mechanism underlying jet lag, we propose a simple model of the SCN, which is a network of phase oscillators. Despite its simplicity, this model can reproduce important dynamical properties of the SCN. For example, this model reproduces the desynchrony of oscillators after jet lag. Moreover, when intercellular interaction is weaker, this desynchrony is suppressed and the recover from jet lag is considerably accelerated. Our mathematical study provides a deeper understanding of jet lag and an idea how to circumvent heavy jet lag symptoms
Synchrony and Desynchrony in Circadian Clocks: Impacts on Learning and Memory
ERIC Educational Resources Information Center
Krishnan, Harini C.; Lyons, Lisa C.
2015-01-01
Circadian clocks evolved under conditions of environmental variation, primarily alternating light dark cycles, to enable organisms to anticipate daily environmental events and coordinate metabolic, physiological, and behavioral activities. However, modern lifestyle and advances in technology have increased the percentage of individuals working in…
Tam, Shu K.E.; Hasan, Sibah; Brown, Laurence A.; Jagannath, Aarti; Hankins, Mark W.; Foster, Russell G.; Vyazovskiy, Vladyslav V.
2017-01-01
Circadian rhythms optimize physiology and behavior to the varying demands of the 24 h day. The master circadian clock is located in the suprachiasmatic nuclei (SCN) of the hypothalamus and it regulates circadian oscillators in tissues throughout the body to prevent internal desynchrony. Here, we demonstrate for the first time that, under standard 12 h:12 h light/dark (LD) cycles, object, visuospatial, and olfactory recognition performance in C57BL/6J mice is consistently better at midday relative to midnight. However, under repeated exposure to constant light (rLL), recognition performance becomes desynchronized, with object and visuospatial performance better at subjective midday and olfactory performance better at subjective midnight. This desynchrony in behavioral performance is mirrored by changes in expression of the canonical clock genes Period1 and Period2 (Per1 and Per2), as well as the immediate-early gene Fos in the SCN, dorsal hippocampus, and olfactory bulb. Under rLL, rhythmic Per1 and Fos expression is attenuated in the SCN. In contrast, hippocampal gene expression remains rhythmic, mirroring object and visuospatial performance. Strikingly, Per1 and Fos expression in the olfactory bulb is reversed, mirroring the inverted olfactory performance. Temporal desynchrony among these regions does not result in arrhythmicity because core body temperature and exploratory activity rhythms persist under rLL. Our data provide the first demonstration that abnormal lighting conditions can give rise to temporal desynchrony between autonomous circadian oscillators in different regions, with different consequences for performance across different sensory domains. Such a dispersed network of dissociable circadian oscillators may provide greater flexibility when faced with conflicting environmental signals. SIGNIFICANCE STATEMENT A master circadian clock in the suprachiasmatic nuclei (SCN) of the hypothalamus regulates physiology and behavior across the 24 h day by synchronizing peripheral clocks throughout the brain and body. Without the SCN, these peripheral clocks rapidly become desynchronized. Here, we provide a unique demonstration that, under lighting conditions in which the central clock in the SCN is dampened, peripheral oscillators in the hippocampus and olfactory bulb become desynchronized, along with the behavioral processes mediated by these clocks. Multiple clocks that adopt different phase relationships may enable processes occurring in different brain regions to be optimized to specific phases of the 24 h day. Moreover, such a dispersed network of dissociable circadian clocks may provide greater flexibility when faced with conflicting environmental signals (e.g., seasonal changes in photoperiod). PMID:28264977
Kosmadopoulos, Anastasi; Sargent, Charli; Darwent, David; Zhou, Xuan; Dawson, Drew; Roach, Gregory D
2014-12-01
Extended wakefulness, sleep loss, and circadian misalignment are factors associated with an increased accident risk in shiftwork. Splitting shifts into multiple shorter periods per day may mitigate these risks by alleviating prior wake. However, the effect of splitting the sleep-wake schedule on the homeostatic and circadian contributions to neurobehavioural performance and subjective assessments of one's ability to perform are not known. Twenty-nine male participants lived in a time isolation laboratory for 13 d, assigned to one of two 28-h forced desynchrony (FD) schedules. Depending on the assigned schedule, participants were provided the same total time in bed (TIB) each FD cycle, either consolidated into a single period (9.33 h TIB) or split into two equal halves (2 × 4.67 h TIB). Neurobehavioural performance was regularly assessed with a psychomotor vigilance task (PVT) and subjectively-assessed ability was measured with a prediction of performance on a visual analogue scale. Polysomnography was used to assess sleep, and core body temperature was recorded to assess circadian phase. On average, participants obtained the same amount of sleep in both schedules, but those in the split schedule obtained more slow wave sleep (SWS) on FD days. Mixed-effects ANOVAs indicated no overall difference between the standard and split schedules in neurobehavioural performance or predictions of performance. Main effects of circadian phase and prior wake were present for both schedules, such that performance and subjective ratings of ability were best around the circadian acrophase, worst around the nadir, and declined with increasing prior wake. There was a schedule by circadian phase interaction for all neurobehavioural performance metrics such that performance was better in the split schedule than the standard schedule around the nadir. There was no such interaction for predictions of performance. Performance during the standard schedule was significantly better than the split schedule at 2 h of prior wake, but declined at a steeper rate such that the schedules converged by 4.5-7 h of prior wake. Overall, the results indicate that when the total opportunity for sleep per day is satisfactory, a split sleep-wake schedule is not detrimental to sleep or performance. Indeed, though not reflected in subjective assessments of performance capacity, splitting the schedule may be of some benefit, given its reduction of neurobehavioural impairment at night and its association with increased SWS. Therefore, for some industries that require operations to be sustained around the clock, implementing a split work-rest schedule may be of assistance.
ERIC Educational Resources Information Center
Bacow, Terri Landon; May, Jill Ehrenreich; Choate-Summers, Molly; Pincus, Donna B.; Mattis, Sara G.
2010-01-01
This study examined the concordance (or synchrony/desynchrony) between adolescents' self-reports of anxiety and physiological measures of arousal (heart rate) both prior to and after treatment for panic disorder. Results indicated a decline in reported subjective units of distress (SUDS) for the treatment group only at the post-treatment…
Circadian Desynchrony Promotes Metabolic Disruption in a Mouse Model of Shiftwork
Barclay, Johanna L.; Husse, Jana; Bode, Brid; Naujokat, Nadine; Meyer-Kovac, Judit; Schmid, Sebastian M.; Lehnert, Hendrik; Oster, Henrik
2012-01-01
Shiftwork is associated with adverse metabolic pathophysiology, and the rising incidence of shiftwork in modern societies is thought to contribute to the worldwide increase in obesity and metabolic syndrome. The underlying mechanisms are largely unknown, but may involve direct physiological effects of nocturnal light exposure, or indirect consequences of perturbed endogenous circadian clocks. This study employs a two-week paradigm in mice to model the early molecular and physiological effects of shiftwork. Two weeks of timed sleep restriction has moderate effects on diurnal activity patterns, feeding behavior, and clock gene regulation in the circadian pacemaker of the suprachiasmatic nucleus. In contrast, microarray analyses reveal global disruption of diurnal liver transcriptome rhythms, enriched for pathways involved in glucose and lipid metabolism and correlating with first indications of altered metabolism. Although altered food timing itself is not sufficient to provoke these effects, stabilizing peripheral clocks by timed food access can restore molecular rhythms and metabolic function under sleep restriction conditions. This study suggests that peripheral circadian desynchrony marks an early event in the metabolic disruption associated with chronic shiftwork. Thus, strengthening the peripheral circadian system by minimizing food intake during night shifts may counteract the adverse physiological consequences frequently observed in human shift workers. PMID:22629359
NASA Technical Reports Server (NTRS)
Klerman, E. B.; Dijk, D. J.; Kronauer, R. E.; Czeisler, C. A.
1996-01-01
The sensitivity of the human circadian system to light has been the subject of considerable debate. Using computer simulations of a recent quantitative model for the effects of light on the human circadian system, we investigated these effects of light during different experimental protocols. The results of the simulations indicate that the nonuniform distribution over the circadian cycle of exposure to ordinary room light seen in classical free-run studies, in which subjects select their exposure to light and darkness, can result in an observed period of approximately 25 h, even when the intrinsic period of the subject's endogenous circadian pacemaker is much closer to 24 h. Other simulation results suggest that accurate assessment of the true intrinsic period of the human circadian pacemaker requires low ambient light intensities (approximately 10-15 lx) during scheduled wake episodes, desynchrony of the imposed light-dark cycle from the endogenous circadian oscillator, and a study length of at least 20 days. Although these simulations await further experimental substantiation, they highlight the sensitivity to light of the human circadian system and the potential confounding influence of light on the assessment of the intrinsic period of the circadian pacemaker.
Prescribed Travel Schedules for Fatigue Management
NASA Technical Reports Server (NTRS)
Whitmire, Alexandra; Johnston, Smith; Lockley, Steven
2011-01-01
The NASA Fatigue Management Team is developing recommendations for managing fatigue during travel and for shift work operations, as Clinical Practice Guidelines for the Management of Circadian Desynchrony in ISS Operations. The Guidelines provide the International Space Station (ISS ) flight surgeons and other operational clinicians with evidence-based recommendations for mitigating fatigue and other factors related to sleep loss and circadian desynchronization. As much international travel is involved both before and after flight, the guidelines provide recommendations for: pre-flight training, in-flight operations, and post-flight rehabilitation. The objective of is to standardize the process by which care is provided to crewmembers, ground controllers, and other support personnel such as trainers, when overseas travel or schedule shifting is required. Proper scheduling of countermeasures - light, darkness, melatonin, diet, exercise, and medications - is the cornerstone for facilitating circadian adaptation, improving sleep, enhancing alertness, and optimizing performance. The Guidelines provide, among other things, prescribed travel schedules that outline the specific implementation of these mitigation strategies. Each travel schedule offers evidence based protocols for properly using the NASA identified countermeasures for fatigue. This presentation will describe the travel implementation schedules and how these can be used to alleviate the effects of jet lag and/or schedule shifts.
Plasticity of the Intrinsic Period of the Human Circadian Timing System
Scheer, Frank A.J.L.; Wright, Kenneth P.; Kronauer, Richard E.; Czeisler, Charles A.
2007-01-01
Human expeditions to Mars will require adaptation to the 24.65-h Martian solar day-night cycle (sol), which is outside the range of entrainment of the human circadian pacemaker under lighting intensities to which astronauts are typically exposed. Failure to entrain the circadian time-keeping system to the desired rest-activity cycle disturbs sleep and impairs cognitive function. Furthermore, differences between the intrinsic circadian period and Earth's 24-h light-dark cycle underlie human circadian rhythm sleep disorders, such as advanced sleep phase disorder and non-24-hour sleep-wake disorders. Therefore, first, we tested whether exposure to a model-based lighting regimen would entrain the human circadian pacemaker at a normal phase angle to the 24.65-h Martian sol and to the 23.5-h day length often required of astronauts during short duration space exploration. Second, we tested here whether such prior entrainment to non-24-h light-dark cycles would lead to subsequent modification of the intrinsic period of the human circadian timing system. Here we show that exposure to moderately bright light (∼450 lux; ∼1.2 W/m2) for the second or first half of the scheduled wake episode is effective for entraining individuals to the 24.65-h Martian sol and a 23.5-h day length, respectively. Estimations of the circadian periods of plasma melatonin, plasma cortisol, and core body temperature rhythms collected under forced desynchrony protocols revealed that the intrinsic circadian period of the human circadian pacemaker was significantly longer following entrainment to the Martian sol as compared to following entrainment to the 23.5-h day. The latter finding of after-effects of entrainment reveals for the first time plasticity of the period of the human circadian timing system. Both findings have important implications for the treatment of circadian rhythm sleep disorders and human space exploration. PMID:17684566
Kosmadopoulos, Anastasi; Sargent, Charli; Zhou, Xuan; Darwent, David; Matthews, Raymond W; Dawson, Drew; Roach, Gregory D
2017-02-01
Fatigue is a significant contributor to motor-vehicle accidents and fatalities. Shift workers are particularly susceptible to fatigue-related risks as they are often sleep-restricted and required to commute around the clock. Simple assays of performance could provide useful indications of risk in fatigue management, but their effectiveness may be influenced by changes in their sensitivity to sleep loss across the day. The aim of this study was to evaluate the sensitivity of several neurobehavioral and subjective tasks to sleep restriction (SR) at different circadian phases and their efficacy as predictors of performance during a simulated driving task. Thirty-two volunteers (M±SD; 22.8±2.9 years) were time-isolated for 13-days and participated in one of two 14-h forced desynchrony protocols with sleep opportunities equivalent to 8h/24h (control) or 4h/24h (SR). At regular intervals during wake periods, participants completed a simulated driving task, several neurobehavioral tasks, including the psychomotor vigilance task (PVT), and subjective ratings, including a self-assessment measure of ability to perform. Scores transformed into standardized units relative to baseline were folded into circadian phase bins based on core body temperature. Sleep dose and circadian phase effect sizes were derived via mixed models analyses. Predictors of driving were identified with regressions. Performance was most sensitive to sleep restriction around the circadian nadir. The effects of sleep restriction around the circadian nadir were larger for simulated driving and neurobehavioral tasks than for subjective ratings. Tasks did not significantly predict driving performance during the control condition or around the acrophase during the SR condition. The PVT and self-assessed ability were the best predictors of simulated driving across circadian phases during SR. These results show that simple performance measures and self-monitoring explain a large proportion of the variance in driving when fatigue-risk is high. Copyright © 2015 Elsevier Ltd. All rights reserved.
Does Timing of Alcohol Administration Affect Sleep?
Van Reen, Eliza; Tarokh, Leila; Rupp, Tracy L.; Seifer, Ron; Carskadon, Mary A.
2011-01-01
Study Objectives: To explore the time of day effects of alcohol on sleep, we examined sleep following alcohol administered at four times of day and three homeostatic loads during a 20-hr forced desynchrony (FD) protocol. Participants: Twenty-six healthy young adults (21–25 yrs) were studied. Design: Participants were dosed at 4 clock times: 0400 (n = 6; 2 females), 1600 (n = 7; 4 females), 1000 (n = 6; 1 female) or 2200 (n = 7; 2 females). Participants slept 2300 to 0800 for at least 12 nights before the in-lab FD study. Double blind placebo and alcohol (vodka tonic targeting 0.05g% concentration) beverages were each administered three times during FD at different homeostatic loads: low (4.25 or 2.24 hrs awake), medium (8.25 or 6.25 hrs awake), high (12.25 or 10.25 hrs awake) in the 0400 and 1600 or 1000 and 2200 groups, respectively. Sleep was staged and subjected to spectral analysis. Measurements and Results: Breath Alcohol Concentration (BrAC) confirmed targeted maximal levels. At bedtime, BrAC was 0 in the low and medium homeostatic load conditions; however, at high homeostatic load, BrAC was still measurable. Spectral characteristics of sleep were unaffected with alcohol at any time of day. Few alcohol related changes were seen for sleep stages; however, with alcohol given at 0400 at a high homeostatic load there was an increase in wake. Conclusions: These data lend support to the idea that alcohol may be disruptive to sleep; however, our findings are inconsistent with the idea that a low dose of alcohol is a useful sleep aid when attempting to sleep at an adverse circadian phase. Citation: Van Reen E; Tarokh L; Rupp TL; Seifer R; Carskadon MA. Does timing of alcohol administration affect sleep? SLEEP 2011;34(2):195-205. PMID:21286495
Study of Opto-electronic Properties of a Single Microtubule in the Microwave Regime
2013-01-09
apparently microtubule grows continuously from tubulins, in that growth randomly triggered rapid growth and long silence modes are superimposed by...synchrony and de-synchrony glues. When such synchrony is introduced in an artificial cell like environment, microtubule does not grow freely, similar to...NOTES 14. ABSTRACT The research establishes the supremacy of synchrony by proving that though apparently microtubule grows continuously from
Fatigue Management in Spaceflight Operations
NASA Technical Reports Server (NTRS)
Whitmire, Alexandra
2011-01-01
Sleep loss and fatigue remain an issue for crewmembers working on the International Space Station, and the ground crews who support them. Schedule shifts on the ISS are required for conducting mission operations. These shifts lead to tasks being performed during the biological night, and sleep scheduled during the biological day, for flight crews and the ground teams who support them. Other stressors have been recognized as hindering sleep in space; these include workload, thinking about upcoming tasks, environmental factors, and inadequate day/night cues. It is unknown if and how other factors such as microgravity, carbon dioxide levels, or increased radiation, may also play a part. Efforts are underway to standardize and provide care for crewmembers, ground controllers and other support personnel. Through collaborations between research and operations, evidenced-based clinical practice guidelines are being developed to equip flight surgeons with the tools and processes needed for treating circadian desynchrony (and subsequent sleep loss) caused by jet lag and shift work. The proper implementation of countermeasures such as schedules, lighting protocols, and cognitive behavioral education can hasten phase shifting, enhance sleep and optimize performance. This panel will focus on Fatigue Management in Spaceflight Operations. Speakers will present on research-based recommendations and technologies aimed at mitigating sleep loss, circadian desynchronization and fatigue on-orbit. Gaps in current mitigations and future recommendations will also be discussed.
Management of Circadian Desynchrony (Jetlag and Shiftlag) in CF Air Operations
2010-12-01
des médecins de l’air sur la gestion pharmaceutique de la manipulation du rythme circadien par la mélatonine, la luminothérapie...opérationnelle dans le cadre d’un plan de gestion de la fatigue. L’utilisation de la resynchronisation du rythme circadien pour contrer le décalage horaire...doivent travailler ensemble à l’élaboration de plans de mise en œuvre opérationnelle de
Validating and Verifying Biomathematical Models of Human Fatigue
NASA Technical Reports Server (NTRS)
Martinez, Siera Brooke; Quintero, Luis Ortiz; Flynn-Evans, Erin
2015-01-01
Airline pilots experience acute and chronic sleep deprivation, sleep inertia, and circadian desynchrony due to the need to schedule flight operations around the clock. This sleep loss and circadian desynchrony gives rise to cognitive impairments, reduced vigilance and inconsistent performance. Several biomathematical models, based principally on patterns observed in circadian rhythms and homeostatic drive, have been developed to predict a pilots levels of fatigue or alertness. These models allow for the Federal Aviation Administration (FAA) and commercial airlines to make decisions about pilot capabilities and flight schedules. Although these models have been validated in a laboratory setting, they have not been thoroughly tested in operational environments where uncontrolled factors, such as environmental sleep disrupters, caffeine use and napping, may impact actual pilot alertness and performance. We will compare the predictions of three prominent biomathematical fatigue models (McCauley Model, Harvard Model, and the privately-sold SAFTE-FAST Model) to actual measures of alertness and performance. We collected sleep logs, movement and light recordings, psychomotor vigilance task (PVT), and urinary melatonin (a marker of circadian phase) from 44 pilots in a short-haul commercial airline over one month. We will statistically compare with the model predictions to lapses on the PVT and circadian phase. We will calculate the sensitivity and specificity of each model prediction under different scheduling conditions. Our findings will aid operational decision-makers in determining the reliability of each model under real-world scheduling situations.
Waking up is the hardest thing I do all day: Sleep inertia and sleep drunkenness.
Trotti, Lynn M
2017-10-01
The transition from sleep to wake is marked by sleep inertia, a distinct state that is measurably different from wakefulness and manifests as performance impairments and sleepiness. Although the precise substrate of sleep inertia is unknown, electroencephalographic, evoked potential, and neuroimaging studies suggest the persistence of some features of sleep beyond the point of awakening. Forced desynchrony studies have demonstrated that sleep inertia impacts cognition differently than do homeostatic and circadian drives and that sleep inertia is most intense during awakenings from the biological night. Recovery sleep after sleep deprivation also amplifies sleep inertia, although the effects of deep sleep vary based on task and timing. In patients with hypersomnolence disorders, especially but not exclusively idiopathic hypersomnia, a more pronounced period of confusion and sleepiness upon awakening, known as "sleep drunkenness", is common and problematic. Optimal treatment of sleep drunkenness is unknown, although several medications have been used with benefit in small case series. Difficulty with awakening is also commonly endorsed by individuals with mood disorders, disproportionately to the general population. This may represent an important treatment target, but evidence-based treatment guidance is not yet available. Copyright © 2016 Elsevier Ltd. All rights reserved.
Coalition Logistics - The Multinational Force and Observers Model
1986-05-19
MISSION The mission of the MFO, as specified by the protocol , is to supervise implemeutation of the peace treaty and to employ its best efforts to prevent ...result, a protocol was -- negotiated, calling for a multinational military force and civilian- ---- observer unit to serve in the Sinai--outside the...auspices of the United Nations.2 In this way, the protocol of 3 August 1981 created the Multinational Force and Observers and directed Lhat it be
García-Ramos, Amador; Torrejón, Alejandro; Feriche, Belén; Morales-Artacho, Antonio J; Pérez-Castilla, Alejandro; Padial, Paulino; Jaric, Slobodan
2018-02-01
This study explored the feasibility of the force-velocity relationship (F-V) to detect the acute effects of different fatigue protocols on the selective changes of the maximal capacities of upper body muscles to produce force, velocity, and power. After determining the bench press one-repetition maximum (1RM), participants' F-V relationships were assessed during the bench press throw exercise on five separate sessions after performing one of the following fatiguing protocols: 60%1RM failure, 60%1RM non-failure, 80%1RM failure, 80%1RM non-failure, and no-fatigue. In the non-failure protocols, participants performed half the maximum number of repetitions than in their respective failure protocols. The main findings revealed that (1) all F-V relationships were highly linear (median r = 0.997 and r = 0.982 for averaged across participants and individual data, respectively), (2) the fatiguing protocols were ranked based on the magnitude of power loss as follows: 60%1RM failure > 80%1RM failure > 60%1RM non-failure > 80%1RM non-failure, while (3) the assessed maximum force and velocity outputs showed a particularly prominent reduction in the protocols based on the lowest and highest levels of fatigue (i.e., 80%1RM non-failure and 60%1RM failure), respectively. The results support the use of F-V to assess the effects of fatigue on the distinctive capacities of the muscles to produce force, velocity, and power output while performing multi-joint tasks, while the assessed maximum force and velocity capacities showed a particularly prominent reduction in the protocols based on the lowest and highest levels of fatigue (i.e., 80%1RM non-failure and 60%1RM failure), respectively.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Uribe, Eva C; Sandoval, M Analisa; Sandoval, Marisa N
2009-01-01
With the 6 January 2009 entry into force of the Additional Protocol by the United States of America, all five declared Nuclear Weapon States that are part of the Nonproliferation Treaty have signed, ratified, and put into force the Additional Protocol. This paper makes a comparison of the strengths and weaknesses of the five Additional Protocols in force by the five Nuclear Weapon States with respect to the benefits to international nonproliferation aims. This paper also documents the added safeguards burden to the five declared Nuclear Weapon States that these Additional Protocols put on the states with respect to accessmore » to their civilian nuclear programs and the hosting of complementary access activities as part of the Additional Protocol.« less
Roberts, Logan; Leise, Tanya L.; Noguchi, Takako; Galschiodt, Alexis M.; Houl, Jerry H.; Welsh, David K.; Holmes, Todd C.
2015-01-01
Summary Background Circadian neural circuits generate near 24 hr physiological rhythms that can be entrained by light to coordinate animal physiology with daily solar cycles. To examine how a circadian circuit reorganizes its activity in response to light, we imaged period (per) clock gene cycling for up to 6 days at single neuron resolution in whole brain explant cultures prepared from per-luciferase transgenic flies. We compared cultures subjected to a phase-advancing light pulse (LP) to cultures maintained in darkness (DD). Results In DD, individual neuronal oscillators in all circadian subgroups are initially well synchronized, then show monotonic decrease in oscillator rhythm amplitude and synchrony with time. The s-LNvs and LNds exhibit this decrease at a slower relative rate. In contrast, the LP evokes a rapid loss of oscillator synchrony between and within most circadian neuronal subgroups followed by gradual phase retuning of whole circuit oscillator synchrony. The LNds maintain high rhythmic amplitude and synchrony following the LP along with the most rapid coherent phase advance. Immunocytochemical analysis of PER show these dynamics in DD and LP are recapitulated in vivo. Anatomically distinct circadian neuronal subgroups vary in their response to the LP, showing differences in the degree and kinetics of their loss, recovery and/or strengthening of synchrony and rhythmicity. Conclusions Transient desynchrony appears to be an integral feature of light response of the Drosophila multicellular circadian clock. Individual oscillators in different neuronal subgroups of the circadian circuit show distinct kinetic signatures of light response and phase retuning. PMID:25754644
Scheer, Frank A. J. L.; Shea, Thomas J.; Hilton, Michael F.; Shea, Steven A.
2011-01-01
Sleep inertia is the impaired cognitive performance immediately upon awakening, which decays over tens of minutes. This phenomenon has relevance to people who need to make important decisions soon after awakening, such as on-call emergency workers. Such awakenings can occur at varied times of day or night, so the objective of the study was to determine whether or not the magnitude of sleep inertia varies according to the phase of the endogenous circadian cycle. Twelve adults (mean, 24 years; 7 men) with no medical disorders other than mild asthma were studied. Following 2 baseline days and nights, subjects underwent a forced desynchrony protocol composed of seven 28-h sleep/wake cycles, while maintaining a sleep/wakefulness ratio of 1:2 throughout. Subjects were awakened by a standardized auditory stimulus 3 times each sleep period for sleep inertia assessments. The magnitude of sleep inertia was quantified as the change in cognitive performance (number of correct additions in a 2-min serial addition test) across the first 20 min of wakefulness. Circadian phase was estimated from core body temperature (fitted temperature minimum assigned 0°). Data were segregated according to: (1) circadian phase (60° bins); (2) sleep stage; and (3) 3rd of the night after which awakenings occurred (i.e., tertiary 1, 2, or 3). To control for any effect of sleep stage, the circadian rhythm of sleep inertia was initially assessed following awakenings from Stage 2 (62% of awakening occurred from this stage; n = 110). This revealed a significant circadian rhythm in the sleep inertia of cognitive performance (p = 0.007), which was 3.6 times larger during the biological night (circadian bin 300°, ~2300–0300 h in these subjects) than during the biological day (bin 180°, ~1500–1900 h). The circadian rhythm in sleep inertia was still present when awakenings from all sleep stages were included (p = 0.004), and this rhythm could not be explained by changes in underlying sleep drive prior to awakening (changes in sleep efficiency across circadian phase or across the tertiaries), or by the proportion of the varied sleep stages prior to awakenings. This robust endogenous circadian rhythm in sleep inertia may have important implications for people who need to be alert soon after awakening. PMID:18663242
Scheer, Frank A J L; Shea, Thomas J; Hilton, Michael F; Shea, Steven A
2008-08-01
Sleep inertia is the impaired cognitive performance immediately upon awakening, which decays over tens of minutes. This phenomenon has relevance to people who need to make important decisions soon after awakening, such as on-call emergency workers. Such awakenings can occur at varied times of day or night, so the objective of the study was to determine whether or not the magnitude of sleep inertia varies according to the phase of the endogenous circadian cycle. Twelve adults (mean, 24 years; 7 men) with no medical disorders other than mild asthma were studied. Following 2 baseline days and nights, subjects underwent a forced desynchrony protocol composed of seven 28-h sleep/wake cycles, while maintaining a sleep/wakefulness ratio of 1:2 throughout. Subjects were awakened by a standardized auditory stimulus 3 times each sleep period for sleep inertia assessments. The magnitude of sleep inertia was quantified as the change in cognitive performance (number of correct additions in a 2-min serial addition test) across the first 20 min of wakefulness. Circadian phase was estimated from core body temperature (fitted temperature minimum assigned 0 degrees ). Data were segregated according to: (1) circadian phase (60 degrees bins); (2) sleep stage; and (3) 3rd of the night after which awakenings occurred (i.e., tertiary 1, 2, or 3). To control for any effect of sleep stage, the circadian rhythm of sleep inertia was initially assessed following awakenings from Stage 2 (62% of awakening occurred from this stage; n = 110). This revealed a significant circadian rhythm in the sleep inertia of cognitive performance (p = 0.007), which was 3.6 times larger during the biological night (circadian bin 300 degrees , approximately 2300-0300 h in these subjects) than during the biological day (bin 180 degrees , approximately 1500-1900 h). The circadian rhythm in sleep inertia was still present when awakenings from all sleep stages were included (p = 0.004), and this rhythm could not be explained by changes in underlying sleep drive prior to awakening (changes in sleep efficiency across circadian phase or across the tertiaries), or by the proportion of the varied sleep stages prior to awakenings. This robust endogenous circadian rhythm in sleep inertia may have important implications for people who need to be alert soon after awakening.
Lee, Michael L; Katsuyama, Ângela M; Duge, Leanne S; Sriram, Chaitra; Krushelnytskyy, Mykhaylo; Kim, Jeansok J; de la Iglesia, Horacio O
2016-11-01
Sleep is important for consolidation of hippocampus-dependent memories. It is hypothesized that the temporal sequence of nonrapid eye movement (NREM) sleep and rapid eye movement (REM) sleep is critical for the weakening of nonadaptive memories and the subsequent transfer of memories temporarily stored in the hippocampus to more permanent memories in the neocortex. A great body of evidence supporting this hypothesis relies on behavioral, pharmacological, neural, and/or genetic manipulations that induce sleep deprivation or stage-specific sleep deprivation. We exploit an experimental model of circadian desynchrony in which intact animals are not deprived of any sleep stage but show fragmentation of REM and NREM sleep within nonfragmented sleep bouts. We test the hypothesis that the shortening of NREM and REM sleep durations post-training will impair memory consolidation irrespective of total sleep duration. When circadian-desynchronized animals are trained in a hippocampus-dependent contextual fear-conditioning task they show normal short-term memory but impaired long-term memory consolidation. This impairment in memory consolidation is positively associated with the post-training fragmentation of REM and NREM sleep but is not significantly associated with the fragmentation of total sleep or the total amount of delta activity. We also show that the sleep stage fragmentation resulting from circadian desynchrony has no effect on hippocampus-dependent spatial memory and no effect on hippocampus-independent cued fear-conditioning memory. Our findings in an intact animal model, in which sleep deprivation is not a confounding factor, support the hypothesis that the stereotypic sequence and duration of sleep stages play a specific role in long-term hippocampus-dependent fear memory consolidation. © 2016 Associated Professional Sleep Societies, LLC.
Sargent, Charli; Zhou, Xuan; Matthews, Raymond W; Darwent, David; Roach, Gregory D
2016-01-29
The impact of sleep restriction on the endogenous circadian rhythms of hunger and satiety were examined in 28 healthy young men. Participants were scheduled to 2 × 24-h days of baseline followed by 8 × 28-h days of forced desynchrony during which sleep was either moderately restricted (equivalent to 6 h in bed/24 h; n = 14) or severely restricted (equivalent to 4 h in bed/24 h; n = 14). Self-reported hunger and satisfaction were assessed every 2.5 h during wake periods using visual analogue scales. Participants were served standardised meals and snacks at regular intervals and were not permitted to eat ad libitum. Core body temperature was continuously recorded with rectal thermistors to determine circadian phase. Both hunger and satiety exhibited a marked endogenous circadian rhythm. Hunger was highest, and satiety was lowest, in the biological evening (i.e., ~17:00-21:00 h) whereas hunger was lowest, and satiety was highest in the biological night (i.e., 01:00-05:00 h). The results are consistent with expectations based on previous reports and may explain in some part the decrease in appetite that is commonly reported by individuals who are required to work at night. Interestingly, the endogenous rhythms of hunger and satiety do not appear to be altered by severe--as compared to moderate--sleep restriction.
Shortcuts to Adiabaticity in Transport of a Single Trapped Ion
NASA Astrophysics Data System (ADS)
An, Shuoming; Lv, Dingshun; Campo, Adolfo Del; Kim, Kihwan
2015-05-01
We report an experimental study on shortcuts to adiabaticity in the transport of a single 171Yb+ ion trapped in a harmonic potential. In these driving schemes, the application of a force induces a nonadiabatic dynamics in which excitations are tailored so as to preserve the ion motional state in the ground state upon completion of the process. We experimentally apply the laser induced force and realize three different protocols: (1) a transitionless driving with a counterdiabatic term out of phase with the displacement force, (2) a classical protocol assisted by counterdiabatic fields in phase with the main force, (3) and an engineered transport protocol based on the Fourier transform of the trap acceleration. We experimentally compare and discuss the robustness of these protocols under given experimental limitations such as trap frequency drifts. This work was supported by the National Basic Research Program of China under Grants No. 2011CBA00300 (No. 2011CBA00301), the National Natural Science Foundation of China 11374178, and the University of Massachusetts Boston (No. P20150000029279).
Steinbacher, M; Vollmer, M K; Buchmann, B; Reimann, S
2008-03-01
A combination of reconstructed histories, long-term time series and recent quasi-continuous observations of non-CO2 greenhouse gases at the high-Alpine site Jungfraujoch is used to assess their current global radiative forcing budget and the influence of regulations due to the Montreal Protocol on Substances that Deplete the Ozone Layer in terms of climate change. Extrapolated atmospheric greenhouse gases trends from 1989 assuming a business-as-usual scenario, i.e. no Montreal Protocol restriction, are presented and compared to the observations. The largest differences between hypothetical business-as-usual mixing ratios and current atmospheric observations over the last 16 years were found for chlorinated species, in particular methyl chloroform (CH3CCl3) at 167 to 203 ppt and chlorofluorocarbon-12 (CFC-12) at 121 to 254 ppt. These prevented increases were used to estimate the effects of their restrictions on the radiative forcing budget. The net direct effect due to the Montreal Protocol regulations reduces global warming and offsets about 14 to 30% of the positive greenhouse effect related to the major greenhouse gases CO2, CH4, N2O and also SF6, and about 12 to 22% of the hypothetical current radiative forcing increase without Montreal Protocol restrictions. Thus, the Montreal Protocol succeeded not only in reducing the atmospheric chlorine content in the atmosphere but also dampened global warming. Nevertheless, the Montreal Protocol controlled species still add to global warming.
In Brief: Kyoto Protocol moves forward
NASA Astrophysics Data System (ADS)
Showstack, Randy
2004-10-01
The Russian cabinet's 30 September endorsement of the Kyoto Protocol to the United Nations Framework Convention on Climate Change (UNFCCC) likely clears the way for the treaty's ratification by that country's parliament and for its entry into force. The protocol enters into force when not less than 55 Parties to the Convention, including industrialized countries (so called ``Annex I Parties'') which accounted in total for at least 55 % of the total carbon dioxide emissions for 1990 from that group, officially have agreed to the treaty.
The importance of the Montreal Protocol in protecting climate.
Velders, Guus J M; Andersen, Stephen O; Daniel, John S; Fahey, David W; McFarland, Mack
2007-03-20
The 1987 Montreal Protocol on Substances that Deplete the Ozone Layer is a landmark agreement that has successfully reduced the global production, consumption, and emissions of ozone-depleting substances (ODSs). ODSs are also greenhouse gases that contribute to the radiative forcing of climate change. Using historical ODSs emissions and scenarios of potential emissions, we show that the ODS contribution to radiative forcing most likely would have been much larger if the ODS link to stratospheric ozone depletion had not been recognized in 1974 and followed by a series of regulations. The climate protection already achieved by the Montreal Protocol alone is far larger than the reduction target of the first commitment period of the Kyoto Protocol. Additional climate benefits that are significant compared with the Kyoto Protocol reduction target could be achieved by actions under the Montreal Protocol, by managing the emissions of substitute fluorocarbon gases and/or implementing alternative gases with lower global warming potentials.
The importance of the Montreal Protocol in protecting climate
Velders, Guus J. M.; Andersen, Stephen O.; Daniel, John S.; Fahey, David W.; McFarland, Mack
2007-01-01
The 1987 Montreal Protocol on Substances that Deplete the Ozone Layer is a landmark agreement that has successfully reduced the global production, consumption, and emissions of ozone-depleting substances (ODSs). ODSs are also greenhouse gases that contribute to the radiative forcing of climate change. Using historical ODSs emissions and scenarios of potential emissions, we show that the ODS contribution to radiative forcing most likely would have been much larger if the ODS link to stratospheric ozone depletion had not been recognized in 1974 and followed by a series of regulations. The climate protection already achieved by the Montreal Protocol alone is far larger than the reduction target of the first commitment period of the Kyoto Protocol. Additional climate benefits that are significant compared with the Kyoto Protocol reduction target could be achieved by actions under the Montreal Protocol, by managing the emissions of substitute fluorocarbon gases and/or implementing alternative gases with lower global warming potentials. PMID:17360370
Attwood, Simon J.; Simpson, Anna M. C.; Stone, Rachael; Hamaia, SamirW.; Roy, Debdulal; Farndale, RichardW.; Ouberai, Myriam; Welland, Mark E.
2012-01-01
Single molecule force spectroscopy is a technique that can be used to probe the interaction force between individual biomolecular species. We focus our attention on the tip and sample coupling chemistry, which is crucial to these experiments. We utilised a novel approach of mixed self-assembled monolayers of alkanethiols in conjunction with a heterobifunctional crosslinker. The effectiveness of the protocol is demonstrated by probing the biotin-avidin interaction. We measured unbinding forces comparable to previously reported values measured at similar loading rates. Specificity tests also demonstrated a significant decrease in recognition after blocking with free avidin. PMID:23202965
Emulation of Industrial Control Field Device Protocols
2013-03-01
platforms such as the Arduino ( based on the Atmel AVR architecture) or popular PIC architecture based devices, which are programmed for specific functions...UNIVERSITY AIR FORCE INSTITUTE OF TECHNOLOGY Wright-Patterson Air Force Base , Ohio DISTRIBUTION STATEMENT A. APPROVED FOR PUBLIC RELEASE; DISTRIBUTION...confidence intervals for the mean. Based on these results, extensive knowledge of the specific implementations of the protocols or timing profiles of the
Lee, Michael L.; Katsuyama, Ângela M.; Duge, Leanne S.; Sriram, Chaitra; Krushelnytskyy, Mykhaylo; Kim, Jeansok J.; de la Iglesia, Horacio O.
2016-01-01
Study Objectives: Sleep is important for consolidation of hippocampus-dependent memories. It is hypothesized that the temporal sequence of nonrapid eye movement (NREM) sleep and rapid eye movement (REM) sleep is critical for the weakening of nonadaptive memories and the subsequent transfer of memories temporarily stored in the hippocampus to more permanent memories in the neocortex. A great body of evidence supporting this hypothesis relies on behavioral, pharmacological, neural, and/or genetic manipulations that induce sleep deprivation or stage-specific sleep deprivation. Methods: We exploit an experimental model of circadian desynchrony in which intact animals are not deprived of any sleep stage but show fragmentation of REM and NREM sleep within nonfragmented sleep bouts. We test the hypothesis that the shortening of NREM and REM sleep durations post-training will impair memory consolidation irrespective of total sleep duration. Results: When circadian-desynchronized animals are trained in a hippocampus-dependent contextual fear-conditioning task they show normal short-term memory but impaired long-term memory consolidation. This impairment in memory consolidation is positively associated with the post-training fragmentation of REM and NREM sleep but is not significantly associated with the fragmentation of total sleep or the total amount of delta activity. We also show that the sleep stage fragmentation resulting from circadian desynchrony has no effect on hippocampus-dependent spatial memory and no effect on hippocampus-independent cued fear-conditioning memory. Conclusions: Our findings in an intact animal model, in which sleep deprivation is not a confounding factor, support the hypothesis that the stereotypic sequence and duration of sleep stages play a specific role in long-term hippocampus-dependent fear memory consolidation. Citation: Lee ML, Katsuyama AM, Duge LS, Sriram C, Krushelnytskyy M, Kim JJ, de la Iglesia HO. Fragmentation of rapid eye movement and nonrapid eye movement sleep without total sleep loss impairs hippocampus-dependent fear memory consolidation. SLEEP 2016;39(11):2021–2031. PMID:27568801
NASA Astrophysics Data System (ADS)
Griffies, Stephen M.; Danabasoglu, Gokhan; Durack, Paul J.; Adcroft, Alistair J.; Balaji, V.; Böning, Claus W.; Chassignet, Eric P.; Curchitser, Enrique; Deshayes, Julie; Drange, Helge; Fox-Kemper, Baylor; Gleckler, Peter J.; Gregory, Jonathan M.; Haak, Helmuth; Hallberg, Robert W.; Heimbach, Patrick; Hewitt, Helene T.; Holland, David M.; Ilyina, Tatiana; Jungclaus, Johann H.; Komuro, Yoshiki; Krasting, John P.; Large, William G.; Marsland, Simon J.; Masina, Simona; McDougall, Trevor J.; Nurser, A. J. George; Orr, James C.; Pirani, Anna; Qiao, Fangli; Stouffer, Ronald J.; Taylor, Karl E.; Treguier, Anne Marie; Tsujino, Hiroyuki; Uotila, Petteri; Valdivieso, Maria; Wang, Qiang; Winton, Michael; Yeager, Stephen G.
2016-09-01
The Ocean Model Intercomparison Project (OMIP) is an endorsed project in the Coupled Model Intercomparison Project Phase 6 (CMIP6). OMIP addresses CMIP6 science questions, investigating the origins and consequences of systematic model biases. It does so by providing a framework for evaluating (including assessment of systematic biases), understanding, and improving ocean, sea-ice, tracer, and biogeochemical components of climate and earth system models contributing to CMIP6. Among the WCRP Grand Challenges in climate science (GCs), OMIP primarily contributes to the regional sea level change and near-term (climate/decadal) prediction GCs.OMIP provides (a) an experimental protocol for global ocean/sea-ice models run with a prescribed atmospheric forcing; and (b) a protocol for ocean diagnostics to be saved as part of CMIP6. We focus here on the physical component of OMIP, with a companion paper (Orr et al., 2016) detailing methods for the inert chemistry and interactive biogeochemistry. The physical portion of the OMIP experimental protocol follows the interannual Coordinated Ocean-ice Reference Experiments (CORE-II). Since 2009, CORE-I (Normal Year Forcing) and CORE-II (Interannual Forcing) have become the standard methods to evaluate global ocean/sea-ice simulations and to examine mechanisms for forced ocean climate variability. The OMIP diagnostic protocol is relevant for any ocean model component of CMIP6, including the DECK (Diagnostic, Evaluation and Characterization of Klima experiments), historical simulations, FAFMIP (Flux Anomaly Forced MIP), C4MIP (Coupled Carbon Cycle Climate MIP), DAMIP (Detection and Attribution MIP), DCPP (Decadal Climate Prediction Project), ScenarioMIP, HighResMIP (High Resolution MIP), as well as the ocean/sea-ice OMIP simulations.
Faster modified protocol for first order reversal curve measurements
NASA Astrophysics Data System (ADS)
De Biasi, Emilio
2017-10-01
In this work we present a faster modified protocol for first order reversal curve (FORC) measurements. The main idea of this procedure is to use the information of the ascending and descending branches constructed through successive sweeps of magnetic field. The new method reduces the number of field sweeps to almost one half as compared to the traditional method. The length of each branch is reduced faster than in the usual FORC protocol. The new method implies not only a new measurement protocol but also a new recipe for the previous treatment of the data. After of these pre-processing, the FORC diagram can be obtained by the conventional methods. In the present work we show that the new FORC procedure leads to results identical to the conventional method if the system under study follows the Stoner-Wohlfarth model with interactions that do not depend of the magnetic state (up or down) of the entities, as in the Preisach model. More specifically, if the coercive and interactions fields are not correlated, and the hysteresis loops have a square shape. Some numerical examples show the comparison between the usual FORC procedure and the propose one. We also discuss that it is possible to find some differences in the case of real systems, due to the magnetic interactions. There is no reason to prefer one FORC method over the other from the point of view of the information to be obtained. On the contrary, the use of both methods could open doors for a more accurate and deep analysis.
Statistics of work performed on a forced quantum oscillator.
Talkner, Peter; Burada, P Sekhar; Hänggi, Peter
2008-07-01
Various aspects of the statistics of work performed by an external classical force on a quantum mechanical system are elucidated for a driven harmonic oscillator. In this special case two parameters are introduced that are sufficient to completely characterize the force protocol. Explicit results for the characteristic function of work and the corresponding probability distribution are provided and discussed for three different types of initial states of the oscillator: microcanonical, canonical, and coherent states. Depending on the choice of the initial state the probability distributions of the performed work may greatly differ. This result in particular also holds true for identical force protocols. General fluctuation and work theorems holding for microcanonical and canonical initial states are confirmed.
Legacy of Environmental Research During the Space Shuttle Program
NASA Technical Reports Server (NTRS)
Lane, Helen W.
2011-01-01
The Space Shuttle Program provided many opportunities to study the role of spaceflight on human life for over the last 30 years and represents the longest and largest U.S. human spaceflight program. Risks to crewmembers were included in the research areas of nutrition, microbiology, toxicology, radiation, and sleep quality. To better understand the Shuttle environment, Crew Health Care System was developed. As part of this system, the Environmental Health Subsystem was developed to monitor the atmosphere for gaseous contaminants and microbial contamination levels and to monitor water quality and radiation. This program expended a great deal of effort in studying and mitigating risks related to contaminations due to food, water, air, surfaces, crewmembers, and payloads including those with animals. As the Shuttle had limited stowage space and food selection, the development of nutritional requirements for crewmembers was imperative. As the Shuttle was a reusable vehicle, microbial contamination was of great concern. The development of monitoring instruments that could withstand the space environment took several years and many variations to come up with a suitable instrument. Research with space radiation provided an improved understanding of the various sources of ionizing radiation and the development of monitoring instrumentation for space weather and the human exposure within the orbiter's cabin. Space toxicology matured to include the management of offgassing products that could pollute the crewmembers air quality. The Shuttle Program implemented a 5-level toxicity rating system and developed new monitoring instrumentation to detect toxic compounds. The environment of space caused circadian desynchrony, sleep deficiency, and fatigue leading to much research and major emphasis on countermeasures. Outcomes of the research in these areas were countermeasures, operational protocols, and hardware. Learning Objectives: This symposium will provide an overview of the major environmental lessons learned and the development of countermeasures, monitoring hardware, and procedures.
Chronic phase advance alters circadian physiological rhythms and peripheral molecular clocks
Wolff, Gretchen; Duncan, Marilyn J.
2013-01-01
Shifting the onset of light, acutely or chronically, can profoundly affect responses to infection, tumor progression, development of metabolic disease, and mortality in mammals. To date, the majority of phase-shifting studies have focused on acute exposure to a shift in the timing of the light cycle, whereas the consequences of chronic phase shifts alone on molecular rhythms in peripheral tissues such as skeletal muscle have not been studied. In this study, we tested the effect of chronic phase advance on the molecular clock mechanism in two phenotypically different skeletal muscles. The phase advance protocol (CPA) involved 6-h phase advances (earlier light onset) every 4 days for 8 wk. Analysis of the molecular clock, via bioluminescence recording, in the soleus and flexor digitorum brevis (FDB) muscles and lung demonstrated that CPA advanced the phase of the rhythm when studied immediately after CPA. However, if the mice were placed into free-running conditions (DD) for 2 wk after CPA, the molecular clock was not phase shifted in the two muscles but was still shifted in the lung. Wheel running behavior remained rhythmic in CPA mice; however, the endogenous period length of the free-running rhythm was significantly shorter than that of control mice. Core body temperature, cage activity, and heart rate remained rhythmic throughout the experiment, although the onset of the rhythms was significantly delayed with CPA. These results provide clues that lifestyles associated with chronic environmental desynchrony, such as shift work, can have disruptive effects on the molecular clock mechanism in peripheral tissues, including both types of skeletal muscle. Whether this can contribute, long term, to increased incidence of insulin resistance/metabolic disease requires further study. PMID:23703115
Single-Cell Force Spectroscopy of Probiotic Bacteria
Beaussart, Audrey; El-Kirat-Chatel, Sofiane; Herman, Philippe; Alsteens, David; Mahillon, Jacques; Hols, Pascal; Dufrêne, Yves F.
2013-01-01
Single-cell force spectroscopy is a powerful atomic force microscopy modality in which a single living cell is attached to the atomic force microscopy cantilever to quantify the forces that drive cell-cell and cell-substrate interactions. Although various single-cell force spectroscopy protocols are well established for animal cells, application of the method to individual bacterial cells remains challenging, mainly owing to the lack of appropriate methods for the controlled attachment of single live cells on cantilevers. We present a nondestructive protocol for single-bacterial cell force spectroscopy, which combines the use of colloidal probe cantilevers and of a bioinspired polydopamine wet adhesive. Living cells from the probiotic species Lactobacillus plantarum are picked up with a polydopamine-coated colloidal probe, enabling us to quantify the adhesion forces between single bacteria and biotic (lectin monolayer) or abiotic (hydrophobic monolayer) surfaces. These minimally invasive single-cell experiments provide novel, to our knowledge, insight into the specific and nonspecific forces driving the adhesion of L. plantarum, and represent a generic platform for studying the molecular mechanisms of cell adhesion in probiotic and pathogenic bacteria. PMID:23663831
Security Verification of Secure MANET Routing Protocols
2012-03-22
SECURITY VERIFICATION OF SECURE MANET ROUTING PROTOCOLS THESIS Matthew F. Steele, Captain, USAF AFIT/GCS/ ENG /12-03 DEPARTMENT OF THE AIR FORCE AIR...States AFIT/GCS/ ENG /12-03 SECURITY VERIFICATION OF SECURE MANET ROUTING PROTOCOLS THESIS Presented to the Faculty Department of Electrical and Computer...DISTRIBUTION UNLIMITED AFIT/GCS/ ENG /12-03 SECURITY VERIFICATION OF SECURE MANET ROUTING PROTOCOLS Matthew F. Steele, B.S.E.E. Captain, USAF
Effect of unilateral knee extensor fatigue on force and balance of the contralateral limb.
Arora, Shruti; Budden, Shawn; Byrne, Jeannette M; Behm, David G
2015-10-01
Fatigue in one limb can decrease force production in the homologous muscle as well as other muscles of the non-fatigued limb affecting balance. The objective of the study was to examine the effect of unilateral knee extensor fatigue on the non-fatigued limb's standing balance, muscle force and activation. Sixteen healthy male subjects performed pre-fatigue balance trials, warm-up exercises, maximum voluntary isometric contractions, a knee extensors fatigue protocol, and post-fatigue balance trials. The fatigue protocol consisted of sets of 15 consecutive isometric contractions of 16 s each with 4 s recovery between repetitions, which were performed at 30% peak force for the dominant knee extensor muscles. Additional sets of contractions continued until a 50% decrease in MVIC knee extensor force was observed. Pre- and post-fatigue balance assessment consisted of transition from double to single leg standing and also single leg standing trials, which were performed bilaterally and in randomized order. The peak force and F100 were significantly decreased by 44.8% (ES = 2.54) and 39.9% (ES = 0.59), respectively, for the fatigued limb post-fatigue. There were no significant changes in the non-fatigued limb's muscle force, activation, muscle onset timing or postural stability parameters. While the lack of change in non-fatigued limb force production is in agreement with some of the previous literature in this area, the lack of effect on postural measures directly contradicts earlier work. It is hypothesized that discrepancies in the duration and the intensity of the fatigue protocol may have accounted for this discrepancy.
Calibrated work function mapping by Kelvin probe force microscopy
NASA Astrophysics Data System (ADS)
Fernández Garrillo, Pablo A.; Grévin, Benjamin; Chevalier, Nicolas; Borowik, Łukasz
2018-04-01
We propose and demonstrate the implementation of an alternative work function tip calibration procedure for Kelvin probe force microscopy under ultrahigh vacuum, using monocrystalline metallic materials with known crystallographic orientation as reference samples, instead of the often used highly oriented pyrolytic graphite calibration sample. The implementation of this protocol allows the acquisition of absolute and reproducible work function values, with an improved uncertainty with respect to unprepared highly oriented pyrolytic graphite-based protocols. The developed protocol allows the local investigation of absolute work function values over nanostructured samples and can be implemented in electronic structures and devices characterization as demonstrated over a nanostructured semiconductor sample presenting Al0.7Ga0.3As and GaAs layers with variable thickness. Additionally, using our protocol we find that the work function of annealed highly oriented pyrolytic graphite is equal to 4.6 ± 0.03 eV.
Carpinella, Ilaria; Cattaneo, Davide; Bertoni, Rita; Ferrarin, Maurizio
2012-05-01
In this pilot study, we compared two protocols for robot-based rehabilitation of upper limb in multiple sclerosis (MS): a protocol involving reaching tasks (RT) requiring arm transport only and a protocol requiring both objects' reaching and manipulation (RMT). Twenty-two MS subjects were assigned to RT or RMT group. Both protocols consisted of eight sessions. During RT training, subjects moved the handle of a planar robotic manipulandum toward circular targets displayed on a screen. RMT protocol required patients to reach and manipulate real objects, by moving the robotic arm equipped with a handle which left the hand free for distal tasks. In both trainings, the robot generated resistive and perturbing forces. Subjects were evaluated with clinical and instrumental tests. The results confirmed that MS patients maintained the ability to adapt to the robot-generated forces and that the rate of motor learning increased across sessions. Robot-therapy significantly reduced arm tremor and improved arm kinematics and functional ability. Compared to RT, RMT protocol induced a significantly larger improvement in movements involving grasp (improvement in Grasp ARAT sub-score: RMT 77.4%, RT 29.5%, p=0.035) but not precision grip. Future studies are needed to evaluate if longer trainings and the use of robotic handles would significantly improve also fine manipulation.
Performance Analysis of the Mobile IP Protocol (RFC 3344 and Related RFCS)
2006-12-01
Encapsulation HMAC Keyed-Hash Message Authentication Code ICMP Internet Control Message Protocol IEEE Institute of Electrical and Electronics Engineers IETF...Internet Engineering Task Force IOS Internetwork Operating System IP Internet Protocol ITU International Telecommunication Union LAN Local Area...network computing. Most organizations today have sophisticated networks that are connected to the Internet. The major benefit reaped from such a
22 CFR 41.12 - Classification symbols.
Code of Federal Regulations, 2010 CFR
2010-04-01
..., Advisers, and Technical Experts of Delegations, or Immediate Family; Dependents of Member of a Force Entering in Accordance with the Provisions of the NATO Status-of-Forces Agreement or in Accordance with the provisions of the “Protocol on the Status of International Military Headquarters”; Members of Such a Force if...
22 CFR 41.12 - Classification symbols.
Code of Federal Regulations, 2011 CFR
2011-04-01
..., Advisers, and Technical Experts of Delegations, or Immediate Family; Dependents of Member of a Force Entering in Accordance with the Provisions of the NATO Status-of-Forces Agreement or in Accordance with the provisions of the “Protocol on the Status of International Military Headquarters”; Members of Such a Force if...
Mammographic compression after breast conserving therapy: Controlling pressure instead of force
DOE Office of Scientific and Technical Information (OSTI.GOV)
Groot, J. E. de, E-mail: jerry.degroot@sigmascreening.com; Branderhorst, W.; Grimbergen, C. A.
Purpose: X-ray mammography is the primary tool for early detection of breast cancer and for follow-up after breast conserving therapy (BCT). BCT-treated breasts are smaller, less elastic, and more sensitive to pain. Instead of the current force-controlled approach of applying the same force to each breast, pressure-controlled protocols aim to improve standardization in terms of physiology by taking breast contact area and inelasticity into account. The purpose of this study is to estimate the potential for pressure protocols to reduce discomfort and pain, particularly the number of severe pain complaints for BCT-treated breasts. Methods: A prospective observational study including 58more » women having one BCT-treated breast and one untreated nonsymptomatic breast, following our hospital's 18 decanewton (daN) compression protocol was performed. Breast thickness, applied force, contact area, mean pressure, breast volume, and inelasticity (mean E-modulus) were statistically compared between the within-women breast pairs, and data were used as predictors for severe pain, i.e., scores 7 and higher on an 11-point Numerical Rating Scale. Curve-fitting models were used to estimate how pressure-controlled protocols affect breast thickness, compression force, and pain experience. Results: BCT-treated breasts had on average 27% smaller contact areas, 30% lower elasticity, and 30% higher pain scores than untreated breasts (allp < 0.001). Contact area was the strongest predictor for severe pain (p < 0.01). Since BCT-treatment is associated with an average 0.36 dm{sup 2} decrease in contact area, as well as increased pain sensitivity, BCT-breasts had on average 5.3 times higher odds for severe pain than untreated breasts. Model estimations for a pressure-controlled protocol with a 10 kPa target pressure, which is below normal arterial pressure, suggest an average 26% (range 10%–36%) reduction in pain score, and an average 77% (range 46%–95%) reduction of the odds for severe pain. The estimated increase in thickness is +6.4% for BCT breasts. Conclusions: After BCT, women have hardly any choice in avoiding an annual follow-up mammogram. Model estimations show that a 10 kPa pressure-controlled protocol has the potential to reduce pain and severe pain particularly for these women. The results highly motivate conducting further research in larger subject groups.« less
Detecting Hidden Communications Protocols
2013-02-11
Protocols FA9550-09-1-0173 Richard R Brooks Clemson University PO Box 340915 Clemson, SC 29634-0915 Air Force Office of Scientific Research/RSL 875...two botnet detection methods: centralized botnet traffic detection using HMMs and probabilistic context-free grammars (PCFGs) for centralized and...final report for the Detecting Hidden Communications Protocols AFOSR grant with R. R. Brooks form Clemson University as PI. The work funded by the
Biogeochemical Protocols and Diagnostics for the CMIP6 Ocean Model Intercomparison Project (OMIP)
NASA Technical Reports Server (NTRS)
Orr, James C.; Najjar, Raymond G.; Aumont, Olivier; Bopp, Laurent; Bullister, John L.; Danabasoglu, Gokhan; Doney, Scott C.; Dunne, John P.; Dutay, Jean-Claude; Graven, Heather;
2017-01-01
The Ocean Model Intercomparison Project (OMIP) focuses on the physics and biogeochemistry of the ocean component of Earth system models participating in the sixth phase of the Coupled Model Intercomparison Project (CMIP6). OMIP aims to provide standard protocols and diagnostics for ocean models, while offering a forum to promote their common assessment and improvement. It also offers to compare solutions of the same ocean models when forced with reanalysis data (OMIP simulations) vs. when integrated within fully coupled Earth system models (CMIP6). Here we detail simulation protocols and diagnostics for OMIP's biogeochemical and inert chemical tracers. These passive-tracer simulations will be coupled to ocean circulation models, initialized with observational data or output from a model spin-up, and forced by repeating the 1948-2009 surface fluxes of heat, fresh water, and momentum. These so-called OMIP-BGC simulations include three inert chemical tracers (CFC-11, CFC-12, SF [subscript] 6) and biogeochemical tracers (e.g., dissolved inorganic carbon, carbon isotopes, alkalinity, nutrients, and oxygen). Modelers will use their preferred prognostic BGC model but should follow common guidelines for gas exchange and carbonate chemistry. Simulations include both natural and total carbon tracers. The required forced simulation (omip1) will be initialized with gridded observational climatologies. An optional forced simulation (omip1-spunup) will be initialized instead with BGC fields from a long model spin-up, preferably for 2000 years or more, and forced by repeating the same 62-year meteorological forcing. That optional run will also include abiotic tracers of total dissolved inorganic carbon and radiocarbon, CTabio and 14CTabio, to assess deep-ocean ventilation and distinguish the role of physics vs. biology. These simulations will be forced by observed atmospheric histories of the three inert gases and CO2 as well as carbon isotope ratios of CO2. OMIP-BGC simulation protocols are founded on those from previous phases of the Ocean Carbon-Cycle Model Intercomparison Project. They have been merged and updated to reflect improvements concerning gas exchange, carbonate chemistry, and new data for initial conditions and atmospheric gas histories. Code is provided to facilitate their implementation.
Biogeochemical protocols and diagnostics for the CMIP6 Ocean Model Intercomparison Project (OMIP)
NASA Astrophysics Data System (ADS)
Orr, James C.; Najjar, Raymond G.; Aumont, Olivier; Bopp, Laurent; Bullister, John L.; Danabasoglu, Gokhan; Doney, Scott C.; Dunne, John P.; Dutay, Jean-Claude; Graven, Heather; Griffies, Stephen M.; John, Jasmin G.; Joos, Fortunat; Levin, Ingeborg; Lindsay, Keith; Matear, Richard J.; McKinley, Galen A.; Mouchet, Anne; Oschlies, Andreas; Romanou, Anastasia; Schlitzer, Reiner; Tagliabue, Alessandro; Tanhua, Toste; Yool, Andrew
2017-06-01
The Ocean Model Intercomparison Project (OMIP) focuses on the physics and biogeochemistry of the ocean component of Earth system models participating in the sixth phase of the Coupled Model Intercomparison Project (CMIP6). OMIP aims to provide standard protocols and diagnostics for ocean models, while offering a forum to promote their common assessment and improvement. It also offers to compare solutions of the same ocean models when forced with reanalysis data (OMIP simulations) vs. when integrated within fully coupled Earth system models (CMIP6). Here we detail simulation protocols and diagnostics for OMIP's biogeochemical and inert chemical tracers. These passive-tracer simulations will be coupled to ocean circulation models, initialized with observational data or output from a model spin-up, and forced by repeating the 1948-2009 surface fluxes of heat, fresh water, and momentum. These so-called OMIP-BGC simulations include three inert chemical tracers (CFC-11, CFC-12, SF6) and biogeochemical tracers (e.g., dissolved inorganic carbon, carbon isotopes, alkalinity, nutrients, and oxygen). Modelers will use their preferred prognostic BGC model but should follow common guidelines for gas exchange and carbonate chemistry. Simulations include both natural and total carbon tracers. The required forced simulation (omip1) will be initialized with gridded observational climatologies. An optional forced simulation (omip1-spunup) will be initialized instead with BGC fields from a long model spin-up, preferably for 2000 years or more, and forced by repeating the same 62-year meteorological forcing. That optional run will also include abiotic tracers of total dissolved inorganic carbon and radiocarbon, CTabio and 14CTabio, to assess deep-ocean ventilation and distinguish the role of physics vs. biology. These simulations will be forced by observed atmospheric histories of the three inert gases and CO2 as well as carbon isotope ratios of CO2. OMIP-BGC simulation protocols are founded on those from previous phases of the Ocean Carbon-Cycle Model Intercomparison Project. They have been merged and updated to reflect improvements concerning gas exchange, carbonate chemistry, and new data for initial conditions and atmospheric gas histories. Code is provided to facilitate their implementation.
Prampolini, Giacomo; Campetella, Marco; De Mitri, Nicola; Livotto, Paolo Roberto; Cacelli, Ivo
2016-11-08
A robust and automated protocol for the derivation of sound force field parameters, suitable for condensed-phase classical simulations, is here tested and validated on several halogenated hydrocarbons, a class of compounds for which standard force fields have often been reported to deliver rather inaccurate performances. The major strength of the proposed protocol is that all of the parameters are derived only from first principles because all of the information required is retrieved from quantum mechanical data, purposely computed for the investigated molecule. This a priori parametrization is carried out separately for the intra- and intermolecular contributions to the force fields, respectively exploiting the Joyce and Picky programs, previously developed in our group. To avoid high computational costs, all quantum mechanical calculations were performed exploiting the density functional theory. Because the choice of the functional is known to be crucial for the description of the intermolecular interactions, a specific procedure is proposed, which allows for a reliable benchmark of different functionals against higher-level data. The intramolecular and intermolecular contribution are eventually joined together, and the resulting quantum mechanically derived force field is thereafter employed in lengthy molecular dynamics simulations to compute several thermodynamic properties that characterize the resulting bulk phase. The accuracy of the proposed parametrization protocol is finally validated by comparing the computed macroscopic observables with the available experimental counterparts. It is found that, on average, the proposed approach is capable of yielding a consistent description of the investigated set, often outperforming the literature standard force fields, or at least delivering results of similar accuracy.
Linear modeling of human hand-arm dynamics relevant to right-angle torque tool interaction.
Ay, Haluk; Sommerich, Carolyn M; Luscher, Anthony F
2013-10-01
A new protocol was evaluated for identification of stiffness, mass, and damping parameters employing a linear model for human hand-arm dynamics relevant to right-angle torque tool use. Powered torque tools are widely used to tighten fasteners in manufacturing industries. While these tools increase accuracy and efficiency of tightening processes, operators are repetitively exposed to impulsive forces, posing risk of upper extremity musculoskeletal injury. A novel testing apparatus was developed that closely mimics biomechanical exposure in torque tool operation. Forty experienced torque tool operators were tested with the apparatus to determine model parameters and validate the protocol for physical capacity assessment. A second-order hand-arm model with parameters extracted in the time domain met model accuracy criterion of 5% for time-to-peak displacement error in 93% of trials (vs. 75% for frequency domain). Average time-to-peak handle displacement and relative peak handle force errors were 0.69 ms and 0.21%, respectively. Model parameters were significantly affected by gender and working posture. Protocol and numerical calculation procedures provide an alternative method for assessing mechanical parameters relevant to right-angle torque tool use. The protocol more closely resembles tool use, and calculation procedures demonstrate better performance of parameter extraction using time domain system identification methods versus frequency domain. Potential future applications include parameter identification for in situ torque tool operation and equipment development for human hand-arm dynamics simulation under impulsive forces that could be used for assessing torque tools based on factors relevant to operator health (handle dynamics and hand-arm reaction force).
Lee, Jumin; Cheng, Xi; Swails, Jason M.; ...
2015-11-12
Here we report that proper treatment of nonbonded interactions is essential for the accuracy of molecular dynamics (MD) simulations, especially in studies of lipid bilayers. The use of the CHARMM36 force field (C36 FF) in different MD simulation programs can result in disagreements with published simulations performed with CHARMM due to differences in the protocols used to treat the long-range and 1-4 nonbonded interactions. In this study, we systematically test the use of the C36 lipid FF in NAMD, GROMACS, AMBER, OpenMM, and CHARMM/OpenMM. A wide range of Lennard-Jones (LJ) cutoff schemes and integrator algorithms were tested to find themore » optimal simulation protocol to best match bilayer properties of six lipids with varying acyl chain saturation and head groups. MD simulations of a 1,2-dipalmitoyl-sn-phosphatidylcholine (DPPC) bilayer were used to obtain the optimal protocol for each program. MD simulations with all programs were found to reasonably match the DPPC bilayer properties (surface area per lipid, chain order parameters, and area compressibility modulus) obtained using the standard protocol used in CHARMM as well as from experiments. The optimal simulation protocol was then applied to the other five lipid simulations and resulted in excellent agreement between results from most simulation programs as well as with experimental data. AMBER compared least favorably with the expected membrane properties, which appears to be due to its use of the hard-truncation in the LJ potential versus a force-based switching function used to smooth the LJ potential as it approaches the cutoff distance. The optimal simulation protocol for each program has been implemented in CHARMM-GUI. This protocol is expected to be applicable to the remainder of the additive C36 FF including the proteins, nucleic acids, carbohydrates, and small molecules.« less
Lee, Jumin; Cheng, Xi; Swails, Jason M; Yeom, Min Sun; Eastman, Peter K; Lemkul, Justin A; Wei, Shuai; Buckner, Joshua; Jeong, Jong Cheol; Qi, Yifei; Jo, Sunhwan; Pande, Vijay S; Case, David A; Brooks, Charles L; MacKerell, Alexander D; Klauda, Jeffery B; Im, Wonpil
2016-01-12
Proper treatment of nonbonded interactions is essential for the accuracy of molecular dynamics (MD) simulations, especially in studies of lipid bilayers. The use of the CHARMM36 force field (C36 FF) in different MD simulation programs can result in disagreements with published simulations performed with CHARMM due to differences in the protocols used to treat the long-range and 1-4 nonbonded interactions. In this study, we systematically test the use of the C36 lipid FF in NAMD, GROMACS, AMBER, OpenMM, and CHARMM/OpenMM. A wide range of Lennard-Jones (LJ) cutoff schemes and integrator algorithms were tested to find the optimal simulation protocol to best match bilayer properties of six lipids with varying acyl chain saturation and head groups. MD simulations of a 1,2-dipalmitoyl-sn-phosphatidylcholine (DPPC) bilayer were used to obtain the optimal protocol for each program. MD simulations with all programs were found to reasonably match the DPPC bilayer properties (surface area per lipid, chain order parameters, and area compressibility modulus) obtained using the standard protocol used in CHARMM as well as from experiments. The optimal simulation protocol was then applied to the other five lipid simulations and resulted in excellent agreement between results from most simulation programs as well as with experimental data. AMBER compared least favorably with the expected membrane properties, which appears to be due to its use of the hard-truncation in the LJ potential versus a force-based switching function used to smooth the LJ potential as it approaches the cutoff distance. The optimal simulation protocol for each program has been implemented in CHARMM-GUI. This protocol is expected to be applicable to the remainder of the additive C36 FF including the proteins, nucleic acids, carbohydrates, and small molecules.
Satellite Communications Using Commercial Protocols
NASA Technical Reports Server (NTRS)
Ivancic, William D.; Griner, James H.; Dimond, Robert; Frantz, Brian D.; Kachmar, Brian; Shell, Dan
2000-01-01
NASA Glenn Research Center has been working with industry, academia, and other government agencies in assessing commercial communications protocols for satellite and space-based applications. In addition, NASA Glenn has been developing and advocating new satellite-friendly modifications to existing communications protocol standards. This paper summarizes recent research into the applicability of various commercial standard protocols for use over satellite and space- based communications networks as well as expectations for future protocol development. It serves as a reference point from which the detailed work can be readily accessed. Areas that will be addressed include asynchronous-transfer-mode quality of service; completed and ongoing work of the Internet Engineering Task Force; data-link-layer protocol development for unidirectional link routing; and protocols for aeronautical applications, including mobile Internet protocol routing for wireless/mobile hosts and the aeronautical telecommunications network protocol.
Protocol and the post-human performativity of security techniques.
O'Grady, Nathaniel
2016-07-01
This article explores the deployment of exercises by the United Kingdom Fire and Rescue Service. Exercises stage, simulate and act out potential future emergencies and in so doing help the Fire and Rescue Service prepare for future emergencies. Specifically, exercises operate to assess and develop protocol; sets of guidelines which plan out the actions undertaken by the Fire and Rescue Service in responding to a fire. In the article I outline and assess the forms of knowledge and technologies, what I call the 'aesthetic forces', by which the exercise makes present and imagines future emergencies. By critically engaging with Karen Barad's notion of post-human performativity, I argue that exercises provide a site where such forces can entangle with one another; creating a bricolage through which future emergencies are evoked sensually and representatively, ultimately making it possible to experience emergencies in the present. This understanding of exercises allows also for critical appraisal of protocol both as phenomena that are produced through the enmeshing of different aesthetic forces and as devices which premise the operation of the security apparatus on contingency.
Bermudez, Eduardo B.; Klerman, Elizabeth B.; Czeisler, Charles A.; Cohen, Daniel A.; Wyatt, James K.; Phillips, Andrew J. K.
2016-01-01
Sleep restriction causes impaired cognitive performance that can result in adverse consequences in many occupational settings. Individuals may rely on self-perceived alertness to decide if they are able to adequately perform a task. It is therefore important to determine the relationship between an individual’s self-assessed alertness and their objective performance, and how this relationship depends on circadian phase, hours since awakening, and cumulative lost hours of sleep. Healthy young adults (aged 18–34) completed an inpatient schedule that included forced desynchrony of sleep/wake and circadian rhythms with twelve 42.85-hour “days” and either a 1:2 (n = 8) or 1:3.3 (n = 9) ratio of sleep-opportunity:enforced-wakefulness. We investigated whether subjective alertness (visual analog scale), circadian phase (melatonin), hours since awakening, and cumulative sleep loss could predict objective performance on the Psychomotor Vigilance Task (PVT), an Addition/Calculation Test (ADD) and the Digit Symbol Substitution Test (DSST). Mathematical models that allowed nonlinear interactions between explanatory variables were evaluated using the Akaike Information Criterion (AIC). Subjective alertness was the single best predictor of PVT, ADD, and DSST performance. Subjective alertness alone, however, was not an accurate predictor of PVT performance. The best AIC scores for PVT and DSST were achieved when all explanatory variables were included in the model. The best AIC score for ADD was achieved with circadian phase and subjective alertness variables. We conclude that subjective alertness alone is a weak predictor of objective vigilant or cognitive performance. Predictions can, however, be improved by knowing an individual’s circadian phase, current wake duration, and cumulative sleep loss. PMID:27019198
Circadian Role in Daily Pattern of Cardiovascular Risk
NASA Astrophysics Data System (ADS)
Ivanov, Plamen Ch.; Hu, Kun; Chen, Zhi; Hilton, Michael F.; Stanley, H. Eugene; Shea, Steven A.
2004-03-01
Numerous epidemiological studies demonstrate that sudden cardiac death, pulmonary embolism, myocardial infarction, and stroke have a 24-hour daily pattern with a broad peak between 9-11am. Such a daily pattern in cardiovascular risk could be attributable to external factors, such as the daily behavior patterns, including sleep-wake cycles and activity levels, or internal factors, such as the endogenous circadian pacemaker. Findings of significant alternations in the temporal organization and nonlinear properties of heartbeat fluctuations with disease and with sleep-wake transitions raise the intriguing possibility that changes in the mechanism of control associated with behavioral sleep-wake transition may be responsible for the increased cardiac instability observed in particular circadian phases. Alternatively, we hypothesize that there is a circadian clock, independent of the sleep-wake cycle, which affects the cardiac dynamics leading to increased cardiovascular risk. We analyzed continuous recordings from healthy subjects during 7 cycles of forced desynchrony routine wherein subjects' sleep-wake cycles are adjusted to 28 hours so that their behaviors occur across all circadian phases. Heartbeat data were divided into one-hour segments. For each segment, we estimated the correlations and the nonlinear properties of the heartbeat fluctuations at the corresponding circadian phase. Since the sleep and wake contributions are equally weighted in our experiment, a change of the properties of the heartbeat dynamics with circadian phase suggest a circadian rhythm. We show significant circadian-mediated alterations in the correlation and nonlinear properties of the heartbeat resembling those observed in patients with heart failure. Remarkably, these dynamical alterations are centered at 60 degrees circadian phase, coinciding with the 9-11am window of cardiac risk.
N-acetylcysteine inhibits muscle fatigue in humans.
Reid, M B; Stokić, D S; Koch, S M; Khawli, F A; Leis, A A
1994-01-01
N-acetylcysteine (NAC) is a nonspecific antioxidant that selectively inhibits acute fatigue of rodent skeletal muscle stimulated at low (but not high) tetanic frequencies and that decreases contractile function of unfatigued muscle in a dose-dependent manner. The present experiments test the hypothesis that NAC pretreatment can inhibit acute muscular fatigue in humans. Healthy volunteers were studied on two occasions each. Subjects were pretreated with NAC 150 mg/kg or 5% dextrose in water by intravenous infusion. The subject then sat in a chair with surface electrodes positioned over the motor point of tibialis anterior, an ankle dorsiflexor of mixed-fiber composition. The muscle was stimulated to contract electrically (40-55 mA, 0.2-ms pulses) and force production was measured. Function of the unfatigued muscle was assessed by measuring the forces produced during maximal voluntary contractions (MVC) of ankle dorsiflexor muscle groups and during electrical stimulation of tibialis anterior at 1, 10, 20, 40, 80, and 120 Hz (protocol 1). Fatigue was produced using repetitive tetanic stimulations at 10 Hz (protocol 1) or 40 Hz (protocol 2); intermittent stimulations subsequently were used to monitor recovery from fatigue. The contralateral leg then was studied using the same protocol. Pretreatment with NAC did not alter the function of unfatigued muscle; MVC performance and the force-frequency relationship of tibialis anterior were unchanged. During fatiguing contractions stimulated at 10 Hz, NAC increased force output by approximately 15% (P < 0.0001), an effect that was evident after 3 min of repetitive contraction (P < 0.0125) and persisted throughout the 30-min protocol. NAC had no effect on fatigue induced using 40 Hz stimuli or on recovery from fatigue. N-acetylcysteine pretreatment can improve performance of human limb muscle during fatiguing exercise, suggesting that oxidative stress plays a causal role in the fatigue process and identifying antioxidant therapy as a novel intervention that may be useful clinically. PMID:7989604
Quantum fluctuation theorems and power measurements
NASA Astrophysics Data System (ADS)
Prasanna Venkatesh, B.; Watanabe, Gentaro; Talkner, Peter
2015-07-01
Work in the paradigm of the quantum fluctuation theorems of Crooks and Jarzynski is determined by projective measurements of energy at the beginning and end of the force protocol. In analogy to classical systems, we consider an alternative definition of work given by the integral of the supplied power determined by integrating up the results of repeated measurements of the instantaneous power during the force protocol. We observe that such a definition of work, in spite of taking account of the process dependence, has different possible values and statistics from the work determined by the conventional two energy measurement approach (TEMA). In the limit of many projective measurements of power, the system’s dynamics is frozen in the power measurement basis due to the quantum Zeno effect leading to statistics only trivially dependent on the force protocol. In general the Jarzynski relation is not satisfied except for the case when the instantaneous power operator commutes with the total Hamiltonian at all times. We also consider properties of the joint statistics of power-based definition of work and TEMA work in protocols where both values are determined. This allows us to quantify their correlations. Relaxing the projective measurement condition, weak continuous measurements of power are considered within the stochastic master equation formalism. Even in this scenario the power-based work statistics is in general not able to reproduce qualitative features of the TEMA work statistics.
Weakley, Jonathon Js; Till, Kevin; Read, Dale B; Phibbs, Padraic J; Roe, Gregory; Darrall-Jones, Joshua; Jones, Ben L
2017-08-04
Training that is efficient and effective is of great importance to an athlete. One method of improving efficiency is by incorporating supersets into resistance training routines. However, the structuring of supersets is still unexplored. Therefore, the purpose of this study was to assess the effects of agonist-antagonist (A-A), alternate peripheral (A-P), and similar biomechanical (SB) superset configurations on rate of perceived exertion (RPE), kinetic and kinematic changes during the bench press. 10 subjects performed resistance training protocols in a randomized-crossover design, with magnitude-based inferences assessing changes/differences within and between protocols. Changes in RPE were very likely and almost certainly greater in the A-P and SB protocols when compared with the A-A, while all superset protocols had very likely to almost certain reductions in mean velocity and power from baseline. Reductions in mean velocity and power were almost certainly greater in the SB protocol, with differences between the A-A and A-P protocols being unclear. Decreases in peak force were likely and almost certain in the A-A and SB protocols respectively, with changes in A-P being unclear. Differences between these protocols showed likely greater decreases in SB peak forces when compared to A-A, with all other superset comparisons being unclear. This study demonstrates the importance of exercise selection when incorporating supersets into a training routine. It is suggested that the practitioner uses A-A supersets when aiming to improve training efficiency and minimize reductions in kinetic and kinematic output of the agonist musculature while completing the barbell bench press.
NASA Astrophysics Data System (ADS)
Harrell, Lee; Moore, Eric; Lee, Sanggap; Hickman, Steven; Marohn, John
2011-03-01
We present data and theoretical signal and noise calculations for a protocol using parametric amplification to evade the inherent tradeoff between signal and detector frequency noise in force-gradient magnetic resonance force microscopy signals, which are manifested as a modulated frequency shift of a high- Q microcantilever. Substrate-induced frequency noise has a 1 / f frequency dependence, while detector noise exhibits an f2 dependence on modulation frequency f . Modulation of sample spins at a frequency that minimizes these two contributions typically results in a surface frequency noise power an order of magnitude or more above the thermal limit and may prove incompatible with sample spin relaxation times as well. We show that the frequency modulated force-gradient signal can be used to excite the fundamental resonant mode of the cantilever, resulting in an audio frequency amplitude signal that is readily detected with a low-noise fiber optic interferometer. This technique allows us to modulate the force-gradient signal at a sufficiently high frequency so that substrate-induced frequency noise is evaded without subjecting the signal to the normal f2 detector noise of conventional demodulation.
Ground reaction forces and knee kinetics during single and repeated badminton lunges.
Lam, Wing Kai; Ding, Rui; Qu, Yi
2017-03-01
Repeated movement (RM) lunge that frequently executed in badminton might be used for footwear evaluation. This study examined the influence of single movement (SM) and RM lunges on the ground reaction forces (GRFs) and knee kinetics during the braking phase of a badminton lunge step. Thirteen male university badminton players performed left-forward lunges in both SM and RM sessions. Force platform and motion capturing system were used to measure GRFs and knee kinetics variables. Paired t-test was performed to determine any significant differences between SM and RM lunges regarding mean and coefficient of variation (CV) in each variable. The kinetics results indicated that compared to SM lunges, the RM lunges had shorter contact time and generated smaller maximum loading rate of impact force, peak knee anterior-posterior force, and peak knee sagittal moment but generated larger peak horizontal resultant forces (Ps < 0.05). Additionally, the RM lunges had lower CV for peak knee medial-lateral and vertical forces (Ps < 0.05). These results suggested that the RM testing protocols had a distinct loading response and adaptation pattern during lunge and that the RM protocol showed higher within-trial reliability, which may be beneficial for the knee joint loading evaluation under different interventions.
Cadigan, Edward W. J.; Collins, Brandon W.; Philpott, Devin T. G.; Kippenhuck, Garreth; Brenton, Mitchell; Button, Duane C.
2017-01-01
Transcranial magnetic (TMS) and motor point stimulation have been used to determine voluntary activation (VA). However, very few studies have directly compared the two stimulation techniques for assessing VA of the elbow flexors. The purpose of this study was to compare TMS and motor point stimulation for assessing VA in non-fatigued and fatigued elbow flexors. Participants performed a fatigue protocol that included twelve, 15 s isometric elbow flexor contractions. Participants completed a set of isometric elbow flexion contractions at 100, 75, 50, and 25% of maximum voluntary contraction (MVC) prior to and following fatigue contractions 3, 6, 9, and 12 and 5 and 10 min post-fatigue. Force and EMG of the bicep and triceps brachii were measured for each contraction. Force responses to TMS and motor point stimulation and EMG responses to TMS (motor evoked potentials, MEPs) and Erb's point stimulation (maximal M-waves, Mmax) were also recorded. VA was estimated using the equation: VA% = (1−SITforce/PTforce) × 100. The resting twitch was measured directly for motor point stimulation and estimated for both motor point stimulation and TMS by extrapolation of the linear regression between the superimposed twitch force and voluntary force. MVC force, potentiated twitch force and VA significantly (p < 0.05) decreased throughout the elbow flexor fatigue protocol and partially recovered 10 min post fatigue. VA was significantly (p < 0.05) underestimated when using TMS compared to motor point stimulation in non-fatigued and fatigued elbow flexors. Motor point stimulation compared to TMS superimposed twitch forces were significantly (p < 0.05) higher at 50% MVC but similar at 75 and 100% MVC. The linear relationship between TMS superimposed twitch force and voluntary force significantly (p < 0.05) decreased with fatigue. There was no change in triceps/biceps electromyography, biceps/triceps MEP amplitudes, or bicep MEP amplitudes throughout the fatigue protocol at 100% MVC. In conclusion, motor point stimulation as opposed to TMS led to a higher estimation of VA in non-fatigued and fatigued elbow flexors. The decreased linear relationship between TMS superimposed twitch force and voluntary force led to an underestimation of the estimated resting twitch force and thus, a reduced VA. PMID:28979211
Cadigan, Edward W J; Collins, Brandon W; Philpott, Devin T G; Kippenhuck, Garreth; Brenton, Mitchell; Button, Duane C
2017-01-01
Transcranial magnetic (TMS) and motor point stimulation have been used to determine voluntary activation (VA). However, very few studies have directly compared the two stimulation techniques for assessing VA of the elbow flexors. The purpose of this study was to compare TMS and motor point stimulation for assessing VA in non-fatigued and fatigued elbow flexors. Participants performed a fatigue protocol that included twelve, 15 s isometric elbow flexor contractions. Participants completed a set of isometric elbow flexion contractions at 100, 75, 50, and 25% of maximum voluntary contraction (MVC) prior to and following fatigue contractions 3, 6, 9, and 12 and 5 and 10 min post-fatigue. Force and EMG of the bicep and triceps brachii were measured for each contraction. Force responses to TMS and motor point stimulation and EMG responses to TMS (motor evoked potentials, MEPs) and Erb's point stimulation (maximal M-waves, M max ) were also recorded. VA was estimated using the equation: VA% = (1- SITforce / PTforce ) × 100. The resting twitch was measured directly for motor point stimulation and estimated for both motor point stimulation and TMS by extrapolation of the linear regression between the superimposed twitch force and voluntary force. MVC force, potentiated twitch force and VA significantly ( p < 0.05) decreased throughout the elbow flexor fatigue protocol and partially recovered 10 min post fatigue. VA was significantly ( p < 0.05) underestimated when using TMS compared to motor point stimulation in non-fatigued and fatigued elbow flexors. Motor point stimulation compared to TMS superimposed twitch forces were significantly ( p < 0.05) higher at 50% MVC but similar at 75 and 100% MVC. The linear relationship between TMS superimposed twitch force and voluntary force significantly ( p < 0.05) decreased with fatigue. There was no change in triceps/biceps electromyography, biceps/triceps MEP amplitudes, or bicep MEP amplitudes throughout the fatigue protocol at 100% MVC. In conclusion, motor point stimulation as opposed to TMS led to a higher estimation of VA in non-fatigued and fatigued elbow flexors. The decreased linear relationship between TMS superimposed twitch force and voluntary force led to an underestimation of the estimated resting twitch force and thus, a reduced VA.
Experience with Delay-Tolerant Networking from Orbit
NASA Technical Reports Server (NTRS)
Ivancic, W.; Eddy, W. M.; Stewart, D.; Wood, L.; Northam, J.; Jackson, C.
2010-01-01
We describe the first use from space of the Bundle Protocol for Delay-Tolerant Networking (DTN) and lessons learned from experiments made and experience gained with this protocol. The Disaster Monitoring Constellation (DMC), constructed by Surrey Satellite Technology Ltd (SSTL), is a multiple-satellite Earth-imaging low-Earth-orbit sensor network in which recorded image swaths are stored onboard each satellite and later downloaded from the satellite payloads to a ground station. Store-and-forward of images with capture and later download gives each satellite the characteristics of a node in a disruption-tolerant network. Originally developed for the Interplanetary Internet, DTNs are now under investigation in an Internet Research Task Force (IRTF) DTN research group (RG), which has developed a bundle architecture and protocol. The DMC is technically advanced in its adoption of the Internet Protocol (IP) for its imaging payloads and for satellite command and control, based around reuse of commercial networking and link protocols. These satellites use of IP has enabled earlier experiments with the Cisco router in Low Earth Orbit (CLEO) onboard the constellation s UK-DMC satellite. Earth images are downloaded from the satellites using a custom IP-based high-speed transfer protocol developed by SSTL, Saratoga, which tolerates unusual link environments. Saratoga has been documented in the Internet Engineering Task Force (IETF) for wider adoption. We experiment with the use of DTNRG bundle concepts onboard the UK-DMC satellite, by examining how Saratoga can be used as a DTN convergence layer to carry the DTNRG Bundle Protocol, so that sensor images can be delivered to ground stations and beyond as bundles. Our practical experience with the first successful use of the DTNRG Bundle Protocol in a space environment gives us insights into the design of the Bundle Protocol and enables us to identify issues that must be addressed before wider deployment of the Bundle Protocol. Published in 2010 by John Wiley & Sons, Ltd. KEY WORDS: Internet; UK-DMC; satellite; Delay-Tolerant Networking (DTN); Bundle Protocol
Qin, J; Choi, K S; Ho, Simon S M; Heng, P A
2008-01-01
A force prediction algorithm is proposed to facilitate virtual-reality (VR) based collaborative surgical simulation by reducing the effect of network latencies. State regeneration is used to correct the estimated prediction. This algorithm is incorporated into an adaptive transmission protocol in which auxiliary features such as view synchronization and coupling control are equipped to ensure the system consistency. We implemented this protocol using multi-threaded technique on a cluster-based network architecture.
Very High-Speed Report File System
1992-12-15
1.5 and 45 Mb/s and is expected 1 Introduction to reach 150 Mb/s. These new technologies pose some challenges to The Internet Protocol (IP) family (IP... Internet Engineering Task Force (IETF) has R taken up the issue, but a definitive answer is probably some time away. The basic issues are the choice of AAL...by an IEEE 802. la Subnetwork Access Protocol (SNAP) However, with a large number of networks all header. The third proposal identifies the protocol
Federal Register 2010, 2011, 2012, 2013, 2014
2013-09-11
... Commission's VRS Reform Order regarding the use of Internet Protocol Captioned Telephone Service (IP CTS... requested clarification would force Purple and other IP CTS providers to cease the provision of IP CTS using... of Internet Protocol Captioned Telephone Service (IP CTS) through Web or wireless technologies...
48 CFR 3452.239-70 - Internet protocol version 6 (IPv6).
Code of Federal Regulations, 2013 CFR
2013-10-01
... (IPv6). 3452.239-70 Section 3452.239-70 Federal Acquisition Regulations System DEPARTMENT OF EDUCATION... Clauses 3452.239-70 Internet protocol version 6 (IPv6). As prescribed in 3439.701, insert the following...) version 6 (IPv6) as set forth in Internet Engineering Task Force (IETF) Request for Comments (RFC) 2460...
Security Analysis of DTN Architecture and Bundle Protocol Specification for Space-Based Networks
NASA Technical Reports Server (NTRS)
Ivancic, William D.
2009-01-01
A Delay-Tolerant Network (DTN) Architecture (Request for Comment, RFC-4838) and Bundle Protocol Specification, RFC-5050, have been proposed for space and terrestrial networks. Additional security specifications have been provided via the Bundle Security Specification (currently a work in progress as an Internet Research Task Force internet-draft) and, for link-layer protocols applicable to Space networks, the Licklider Transport Protocol Security Extensions. This document provides a security analysis of the current DTN RFCs and proposed security related internet drafts with a focus on space-based communication networks, which is a rather restricted subset of DTN networks. Note, the original focus and motivation of DTN work was for the Interplanetary Internet . This document does not address general store-and-forward network overlays, just the current work being done by the Internet Research Task Force (IRTF) and the Consultative Committee for Space Data Systems (CCSDS) Space Internetworking Services Area (SIS) - DTN working group under the DTN and Bundle umbrellas. However, much of the analysis is relevant to general store-and-forward overlays.
Physiological links of circadian clock and biological clock of aging.
Liu, Fang; Chang, Hung-Chun
2017-07-01
Circadian rhythms orchestrate biochemical and physiological processes in living organisms to respond the day/night cycle. In mammals, nearly all cells hold self-sustained circadian clocks meanwhile couple the intrinsic rhythms to systemic changes in a hierarchical manner. The suprachiasmatic nucleus (SCN) of the hypothalamus functions as the master pacemaker to initiate daily synchronization according to the photoperiod, in turn determines the phase of peripheral cellular clocks through a variety of signaling relays, including endocrine rhythms and metabolic cycles. With aging, circadian desynchrony occurs at the expense of peripheral metabolic pathologies and central neurodegenerative disorders with sleep symptoms, and genetic ablation of circadian genes in model organisms resembled the aging-related features. Notably, a number of studies have linked longevity nutrient sensing pathways in modulating circadian clocks. Therapeutic strategies that bridge the nutrient sensing pathways and circadian clock might be rational designs to defy aging.
The NIMH Research Domain Criteria Initiative: Background, Issues, and Pragmatics.
Kozak, Michael J; Cuthbert, Bruce N
2016-03-01
This article describes the National Institute of Mental Health's Research Domain Criteria (RDoC) initiative. The description includes background, rationale, goals, and the way the initiative has been developed and organized. The central RDoC concepts are summarized and the current matrix of constructs that have been vetted by workshops of extramural scientists is depicted. A number of theoretical and methodological issues that can arise in connection with the nature of RDoC constructs are highlighted: subjectivism and heterophenomenology, desynchrony and theoretical neutrality among units of analysis, theoretical reductionism, endophenotypes, biomarkers, neural circuits, construct "grain size," and analytic challenges. The importance of linking RDoC constructs to psychiatric clinical problems is discussed. Some pragmatics of incorporating RDoC concepts into applications for NIMH research funding are considered, including sampling design. Published 2016. This article is a U.S. Government work and is in the public domain in the USA.
Bennett, Charles R; DiAngelo, Denis J; Kelly, Brian P
2015-01-01
Extremely few in-vitro biomechanical studies have incorporated shear loads leaving a gap for investigation, especially when applied in combination with compression and bending under dynamic conditions. The objective of this study was to biomechanically compare sagittal plane application of two standard protocols, pure moment (PM) and follower load (FL), with a novel trunk weight (TW) loading protocol designed to induce shear in combination with compression and dynamic bending in a neutrally potted human cadaveric L4-L5 motion segment unit (MSU) model. A secondary objective and novelty of the current study was the application of all three protocols within the same testing system serving to reduce artifacts due to testing system variability. Six L4-L5 segments were tested in a Cartesian load controlled system in flexion-extension to 8Nm under PM, simulated ideal 400N FL, and vertically oriented 400N TW loading protocols. Comparison metrics used were rotational range of motion (RROM), flexibility, neutral zone (NZ) range of motion, and L4 vertebral body displacements. Significant differences in vertebral body translations were observed with different initial force applications but not with subsequent bending moment application. Significant reductions were observed in combined flexion-extension RROM, in flexibility during extension, and in NZ region flexibility with the TW loading protocol as compared to PM loading. Neutral zone ranges of motion were not different between all protocols. The combined compression and shear forces applied across the spinal joint in the trunk weight protocol may have a small but significantly increased stabilizing effect on segment flexibility and kinematics during sagittal plane flexion and extension.
Bennett, Charles R.; DiAngelo, Denis J.
2015-01-01
Background Extremely few in-vitro biomechanical studies have incorporated shear loads leaving a gap for investigation, especially when applied in combination with compression and bending under dynamic conditions. The objective of this study was to biomechanically compare sagittal plane application of two standard protocols, pure moment (PM) and follower load (FL), with a novel trunk weight (TW) loading protocol designed to induce shear in combination with compression and dynamic bending in a neutrally potted human cadaveric L4-L5 motion segment unit (MSU) model. A secondary objective and novelty of the current study was the application of all three protocols within the same testing system serving to reduce artifacts due to testing system variability. Methods Six L4-L5 segments were tested in a Cartesian load controlled system in flexion-extension to 8Nm under PM, simulated ideal 400N FL, and vertically oriented 400N TW loading protocols. Comparison metrics used were rotational range of motion (RROM), flexibility, neutral zone (NZ) range of motion, and L4 vertebral body displacements. Results Significant differences in vertebral body translations were observed with different initial force applications but not with subsequent bending moment application. Significant reductions were observed in combined flexion-extension RROM, in flexibility during extension, and in NZ region flexibility with the TW loading protocol as compared to PM loading. Neutral zone ranges of motion were not different between all protocols. Conclusions The combined compression and shear forces applied across the spinal joint in the trunk weight protocol may have a small but significantly increased stabilizing effect on segment flexibility and kinematics during sagittal plane flexion and extension. PMID:26273551
A mechanical protocol to replicate impact in walking footwear.
Price, Carina; Cooper, Glen; Graham-Smith, Philip; Jones, Richard
2014-01-01
Impact testing is undertaken to quantify the shock absorption characteristics of footwear. The current widely reported mechanical testing method mimics the heel impact in running and therefore applies excessive energy to walking footwear. The purpose of this study was to modify the ASTM protocol F1614 (Procedure A) to better represent walking gait. This was achieved by collecting kinematic and kinetic data while participants walked in four different styles of walking footwear (trainer, oxford shoe, flip-flop and triple-density sandal). The quantified heel-velocity and effective mass at ground-impact were then replicated in a mechanical protocol. The kinematic data identified different impact characteristics in the footwear styles. Significantly faster heel velocity towards the floor was recorded walking in the toe-post sandals (flip-flop and triple-density sandal) compared with other conditions (e.g. flip-flop: 0.36±0.05 ms(-1) versus trainer: 0.18±0.06 ms(-1)). The mechanical protocol was adapted by altering the mass and drop height specific to the data captured for each shoe (e.g. flip-flop: drop height 7 mm, mass 16.2 kg). As expected, the adapted mechanical protocol produced significantly lower peak force and accelerometer values than the ASTM protocol (p<.001). The mean difference between the human and adapted protocol was 12.7±17.5% (p<.001) for peak acceleration and 25.2±17.7% (p=.786) for peak force. This paper demonstrates that altered mechanical test protocols can more closely replicate loading on the lower limb in walking. This therefore suggests that testing of material properties of footbeds not only needs to be gait style specific (e.g. running versus walking), but also footwear style specific. Copyright © 2014 Elsevier B.V. All rights reserved.
Use of the Delay-Tolerant Networking Bundle Protocol from Space
NASA Technical Reports Server (NTRS)
Wood, Lloyd; Ivancic, William D.; Eddy, Wesley M.; Stewart, Dave; Northam, James; Jackson, Chris; daSilvaCuriel, Alex
2009-01-01
The Disaster Monitoring Constellation (DMC), constructed by Survey Satellite Technology Ltd (SSTL), is a multisatellite Earth-imaging low-Earth-orbit sensor network where captured image swaths are stored onboard each satellite and later downloaded from the satellite payloads to a ground station. Store-and-forward of images with capture and later download gives each satellite the characteristics of a node in a Delay/Disruption Tolerant Network (DTN). Originally developed for the Interplanetary Internet, DTNs are now under investigation in an Internet Research Task Force (IRTF) DTN research group (RG), which has developed a bundle architecture and protocol. The DMC is currently unique in its adoption of the Internet Protocol (IP) for its imaging payloads and for satellite command and control, based around reuse of commercial networking and link protocols. These satellites use of IP has enabled earlier experiments with the Cisco router in Low Earth Orbit (CLEO) onboard the constellation's UK-DMC satellite. Earth images are downloaded from the satellites using a custom IPbased high-speed transfer protocol developed by SSTL, Saratoga, which tolerates unusual link environments. Saratoga has been documented in the Internet Engineering Task Force (IETF) for wider adoption. We experiment with use of DTNRG bundle concepts onboard the UKDMC satellite, by examining how Saratoga can be used as a DTN convergence layer to carry the DTNRG Bundle Protocol, so that sensor images can be delivered to ground stations and beyond as bundles. This is the first successful use of the DTNRG Bundle Protocol in a space environment. We use our practical experience to examine the strengths and weaknesses of the Bundle Protocol for DTN use, paying attention to fragmentation, custody transfer, and reliability issues.
de Paula Simola, Rauno Á; Harms, Nico; Raeder, Christian; Kellmann, Michael; Meyer, Tim; Pfeiffer, Mark; Ferrauti, Alexander
2015-05-01
The purpose of the study was to analyze tensiomyography (TMG) sensitivity to changes in muscle force and neuromuscular function of the muscle rectus femoris (RF) using TMG muscle properties after 5 different lower-limb strength training protocols (multiple sets; DS = drop sets; eccentric overload; FW = flywheel; PL = plyometrics). After baseline measurements, 14 male strength trained athletes completed 1 squat training protocol per week over a 5-week period in a randomized controlled order. Maximal voluntary isometric contraction (MVIC), TMG measurements of maximal radial displacement of the muscle belly (Dm), contraction time between 10 and 90% of Dm (Tc), and mean muscle contraction velocities from the beginning until 10% (V10) and 90% of Dm (V90) were analyzed up to 0.5 (post-train), 24 (post-24), and 48 hours (post-48) after the training interventions. Significant analysis of variance main effects for measurement points were found for all TMG contractile properties and MVIC (p < 0.01). Dm and V10 post-train values were significantly lower after protocols DS and FW compared with protocol PL (p = 0.032 and 0.012, respectively). Dm, V10, and V90 decrements correlated significantly to the decreases in MVIC (r = 0.64-0.67, p ≤ 0.05). Some TMG muscle properties are sensitive to changes in muscle force, and different lower-limb strength training protocols lead to changes in neuromuscular function of RF. In addition, those protocols involving high and eccentric load and a high total time under tension may induce higher changes in TMG muscle properties.
48 CFR 3452.239-70 - Internet protocol version 6 (IPv6).
Code of Federal Regulations, 2012 CFR
2012-10-01
... 6 (IPv6). 3452.239-70 Section 3452.239-70 Federal Acquisition Regulations System DEPARTMENT OF... Provisions and Clauses 3452.239-70 Internet protocol version 6 (IPv6). As prescribed in 3439.701, insert the...) version 6 (IPv6) as set forth in Internet Engineering Task Force (IETF) Request for Comments (RFC) 2460...
48 CFR 3452.239-70 - Internet protocol version 6 (IPv6).
Code of Federal Regulations, 2014 CFR
2014-10-01
... 6 (IPv6). 3452.239-70 Section 3452.239-70 Federal Acquisition Regulations System DEPARTMENT OF... Provisions and Clauses 3452.239-70 Internet protocol version 6 (IPv6). As prescribed in 3439.701, insert the...) version 6 (IPv6) as set forth in Internet Engineering Task Force (IETF) Request for Comments (RFC) 2460...
Comparing the force ripple during asynchronous and conventional stimulation.
Downey, Ryan J; Tate, Mark; Kawai, Hiroyuki; Dixon, Warren E
2014-10-01
Asynchronous stimulation has been shown to reduce fatigue during electrical stimulation; however, it may also exhibit a force ripple. We quantified the ripple during asynchronous and conventional single-channel transcutaneous stimulation across a range of stimulation frequencies. The ripple was measured during 5 asynchronous stimulation protocols, 2 conventional stimulation protocols, and 3 volitional contractions in 12 healthy individuals. Conventional 40 Hz and asynchronous 16 Hz stimulation were found to induce contractions that were as smooth as volitional contractions. Asynchronous 8, 10, and 12 Hz stimulation induced contractions with significant ripple. Lower stimulation frequencies can reduce fatigue; however, they may also lead to increased ripple. Future efforts should study the relationship between force ripple and the smoothness of the evoked movements in addition to the relationship between stimulation frequency and NMES-induced fatigue to elucidate an optimal stimulation frequency for asynchronous stimulation. © 2014 Wiley Periodicals, Inc.
Baumgarten, Keith M; Oliver, Harvey A; Foley, Jack; Chen, Ding-Geng; Autenried, Peter; Duan, Shanzhong; Heiser, Patrick
2013-05-01
There have been few scientific studies that have examined usage of human growth hormone to accelerate recovery from injury. The hypothesis of this study was that human growth hormone would accelerate tendon-to-bone healing compared with control animals treated with placebo in a rat model of acute rotator cuff injury repair. Seventy-two rats underwent repair of acute rotator cuff injuries and were randomized into the following postoperative dosing regimens: placebo, and human growth hormone at 0.1, 1, 2, 5, and 10 mg/kg/day, administered subcutaneously once per day for fourteen days (Protocol 1). An additional twenty-four rats were randomized to receive either (1) placebo or (2) human growth hormone at 5 mg/kg, administered subcutaneously twice per day for seven days preoperatively and twenty-eight days postoperatively (Protocol 2). All rats were killed twenty-eight days postoperatively. Mechanical testing was performed. Ultimate stress, ultimate force, stiffness, energy to failure, and ultimate distension were determined. For Protocol 1, analysis of variance testing showed no significant difference between the groups with regard to ultimate stress, ultimate force, stiffness, energy to failure, or ultimate distension. In Protocol 2, ultimate force to failure was significantly worse in the human growth hormone group compared with the placebo group (21.1 ± 5.85 versus 26.3 ± 5.47 N; p = 0.035). Failure was more likely to occur through the bone than the tendon-bone interface in the human growth hormone group compared with the placebo group (p = 0.001). No significant difference was found for ultimate stress, ultimate force, stiffness, energy to failure, or ultimate distension between the groups in Protocol 2. In this rat model of acute tendon-bone injury repair, daily subcutaneous postoperative human growth hormone treatment for fourteen days failed to demonstrate a significant difference in any biomechanical parameter compared with placebo. Furthermore, subcutaneous administration of 5 mg/kg of human growth hormone twice daily from seven days preoperatively until twenty-eight days postoperatively demonstrated lower loads to ultimate failure and a higher risk of bone fracture failure compared with placebo.
NASA Technical Reports Server (NTRS)
Zanchettin, Davide; Khodri, Myriam; Timmreck, Claudia; Toohey, Matthew; Schmidt, Anja; Gerber, Edwin P.; Hegerl, Gabriele; Robock, Alan; Pausata, Francesco; Ball, William T.;
2016-01-01
The enhancement of the stratospheric aerosol layer by volcanic eruptions induces a complex set of responses causing global and regional climate effects on a broad range of timescales. Uncertainties exist regarding the climatic response to strong volcanic forcing identified in coupled climate simulations that contributed to the fifth phase of the Coupled Model Intercomparison Project (CMIP5). In order to better understand the sources of these model diversities, the Model Intercomparison Project on the climatic response to Volcanic forcing (VolMIP) has defined a coordinated set of idealized volcanic perturbation experiments to be carried out in alignment with the CMIP6 protocol. VolMIP provides a common stratospheric aerosol data set for each experiment to minimize differences in the applied volcanic forcing. It defines a set of initial conditions to assess how internal climate variability contributes to determining the response. VolMIP will assess to what extent volcanically forced responses of the coupled ocean-atmosphere system are robustly simulated by state-of-the-art coupled climate models and identify the causes that limit robust simulated behavior, especially differences in the treatment of physical processes. This paper illustrates the design of the idealized volcanic perturbation experiments in the VolMIP protocol and describes the common aerosol forcing input data sets to be used.
Quantum fluctuation theorems and generalized measurements during the force protocol.
Watanabe, Gentaro; Venkatesh, B Prasanna; Talkner, Peter; Campisi, Michele; Hänggi, Peter
2014-03-01
Generalized measurements of an observable performed on a quantum system during a force protocol are investigated and conditions that guarantee the validity of the Jarzynski equality and the Crooks relation are formulated. In agreement with previous studies by M. Campisi, P. Talkner, and P. Hänggi [Phys. Rev. Lett. 105, 140601 (2010); Phys. Rev. E 83, 041114 (2011)], we find that these fluctuation relations are satisfied for projective measurements; however, for generalized measurements special conditions on the operators determining the measurements need to be met. For the Jarzynski equality to hold, the measurement operators of the forward protocol must be normalized in a particular way. The Crooks relation additionally entails that the backward and forward measurement operators depend on each other. Yet, quite some freedom is left as to how the two sets of operators are interrelated. This ambiguity is removed if one considers selective measurements, which are specified by a joint probability density function of work and measurement results of the considered observable. We find that the respective forward and backward joint probabilities satisfy the Crooks relation only if the measurement operators of the forward and backward protocols are the time-reversed adjoints of each other. In this case, the work probability density function conditioned on the measurement result satisfies a modified Crooks relation. The modification appears as a protocol-dependent factor that can be expressed by the information gained by the measurements during the forward and backward protocols. Finally, detailed fluctuation theorems with an arbitrary number of intervening measurements are obtained.
Noise-Enhanced Eversion Force Sense in Ankles With or Without Functional Instability.
Ross, Scott E; Linens, Shelley W; Wright, Cynthia J; Arnold, Brent L
2015-08-01
Force sense impairments are associated with functional ankle instability. Stochastic resonance stimulation (SRS) may have implications for correcting these force sense deficits. To determine if SRS improved force sense. Case-control study. Research laboratory. Twelve people with functional ankle instability (age = 23 ± 3 years, height = 174 ± 8 cm, mass = 69 ± 10 kg) and 12 people with stable ankles (age = 22 ± 2 years, height = 170 ± 7 cm, mass = 64 ± 10 kg). The eversion force sense protocol required participants to reproduce a targeted muscle tension (10% of maximum voluntary isometric contraction). This protocol was assessed under SRSon and SRSoff (control) conditions. During SRSon, random subsensory mechanical noise was applied to the lower leg at a customized optimal intensity for each participant. Constant error, absolute error, and variable error measures quantified accuracy, overall performance, and consistency of force reproduction, respectively. With SRS, we observed main effects for force sense absolute error (SRSoff = 1.01 ± 0.67 N, SRSon = 0.69 ± 0.42 N) and variable error (SRSoff = 1.11 ± 0.64 N, SRSon = 0.78 ± 0.56 N) (P < .05). No other main effects or treatment-by-group interactions were found (P > .05). Although SRS reduced the overall magnitude (absolute error) and variability (variable error) of force sense errors, it had no effect on the directionality (constant error). Clinically, SRS may enhance muscle tension ability, which could have treatment implications for ankle stability.
Bradshaw, Richard T; Essex, Jonathan W
2016-08-09
Hydration free energy (HFE) calculations are often used to assess the performance of biomolecular force fields and the quality of assigned parameters. The AMOEBA polarizable force field moves beyond traditional pairwise additive models of electrostatics and may be expected to improve upon predictions of thermodynamic quantities such as HFEs over and above fixed-point-charge models. The recent SAMPL4 challenge evaluated the AMOEBA polarizable force field in this regard but showed substantially worse results than those using the fixed-point-charge GAFF model. Starting with a set of automatically generated AMOEBA parameters for the SAMPL4 data set, we evaluate the cumulative effects of a series of incremental improvements in parametrization protocol, including both solute and solvent model changes. Ultimately, the optimized AMOEBA parameters give a set of results that are not statistically significantly different from those of GAFF in terms of signed and unsigned error metrics. This allows us to propose a number of guidelines for new molecule parameter derivation with AMOEBA, which we expect to have benefits for a range of biomolecular simulation applications such as protein-ligand binding studies.
Eustachian tube function in adults without middle ear disease.
Swarts, J Douglas; Alper, Cuneyt M; Mandel, Ellen M; Villardo, Richard; Doyle, William J
2011-04-01
We sought to develop normative values for 5 eustachian tube function (ETF) test protocols in adults without otitis media (OM). Twenty adults (19 to 48 years of age) without a recent history of OM (5 had OM in childhood) underwent unilateral myringotomy and were evaluated for ETF by use of the forced response, inflation, deflation, forcible "sniff", and Valsalva test protocols. When possible, these tests were repeated on a second day. Normative values for the parameters of these protocols in adult subjects without a recent history of OM were developed. Between-day data for the forced response test were highly correlated. A percentage of these tests showed eustachian tube "constriction" during swallowing--an abnormal condition. The percent reduction in applied pressures for the inflation and deflation tests was high, indicative of good ETF. Few subjects had a positive "sniff" test, whereas most had a positive Valsalva test, and the results for both tests were effort-dependent. Results of ETF tests in adults with and without recent OM have not been published. Normative data are now available for comparison with ETF test results in adults with OM. These protocols will be used to evaluate the efficacy of surgical procedures designed to improve ETF.
Coexistence of twitch potentiation and tetanic force decline in rat hindlimb muscle
NASA Technical Reports Server (NTRS)
Rankin, Lucinda L.; Enoka, Roger M.; Volz, Kathryn A.; Stuart, Douglas G.
1988-01-01
The effect of whole-muscle fatigue on the isometric twitch was investigated in various hindlimb muscles of anesthetized rats, using an experimental protocol designed to assess the levels of fatigability in motor units. The results of EMG and force measurements revealed the existence of a linear relationship between fatigability and the magnitude of the twitch force following the fatigue test in both soleus and extensor digitorum longus muscles.
1985-03-01
model referred to by the study group . IMCKIiN cuINICATION 31215FOR SDATA TWSU•l Sa *BSTtEO POOTO• AA14FTICT’WI PEM1 ITS ...operating systems, compared the DOD and ISO networking protocol architecture models , the protocols for LAN’s developed by the IEEE and ANSI, reviewed and...be initiated, so as to provide the Air Force a roadmap to guide its * "technology develop •ents. 4,’ /LAN 3-4 .°. SECTION 4.0
Krkeljas, Zarko
2017-07-21
The objective of the study was to determine whether a relationship exists between the two common methods for assessing postural stability in athletes: the time-to-stabilisation (TTS) via force-plate and the Biodex Balance System (BBS). The conditions under which these measurements assess dynamic postural control may not provide sufficient feedback to practitioners. Fourty-four amateur soccer players with no history of musculoskeletal disorders volunteered for the study. Pearson correlation was used to compare the anterior-posterior (AP), medio-lateral (ML), and the overall stability indexes measured by BBS, with the corresponding parameters of TTS assessed via force plate. There was no significant correlation between any parameters of dynamic stability measured by force-plate and the stability indexes. However, there was a significant correlation between the resulting vectors and the AP component of TTS for each jump protocol. Furthermore, forward drop landing exhibited shortest TTS in AP direction, while lateral drop landing resulted in longer ML TTS relative to both forward jumps (p < 0.001). These results demonstrate that the TTS and BBS stability indexes should be used as distinct measures of dynamic postural stability. TTS protocols may be modified to target a specific training conditions or athletic population.
Anbarian, Mehrdad; Esmaeili, Hamed
2016-07-01
This study aimed to assess the effects of running-induced fatigue on plantar pressure parameters in novice runners with low and high medial longitudinal arch. Plantar pressure data from 42 novice runners (21 with high, and 21 with low arch) were collected before and after running-induced fatigue protocol during running at 3.3m/s along the Footscan(®) platform. Peak plantar pressure, peak force and force-time integral (impulse) were measured in ten anatomical zones. Relative time for foot roll-over phases and medio-lateral force ratio were calculated before and after the fatigue protocol. After the fatigue protocol, increases in the peak pressure under the first-third metatarsal zones and reduction under the fourth-fifth metatarsal regions were observed in the low arch individuals. In the high arch group, increases in peak pressure under the fourth-fifth metatarsal zones after the running-induced fatigue was observed. It could be concluded that running-induced fatigue had different effects on plantar pressure distribution pattern among novice runners with low and high medial longitudinal foot arch. These findings could provide some information related to several running injuries among individuals with different foot types. Copyright © 2016 Elsevier B.V. All rights reserved.
Computer-generated forces in distributed interactive simulation
NASA Astrophysics Data System (ADS)
Petty, Mikel D.
1995-04-01
Distributed Interactive Simulation (DIS) is an architecture for building large-scale simulation models from a set of independent simulator nodes communicating via a common network protocol. DIS is most often used to create a simulated battlefield for military training. Computer Generated Forces (CGF) systems control large numbers of autonomous battlefield entities in a DIS simulation using computer equipment and software rather than humans in simulators. CGF entities serve as both enemy forces and supplemental friendly forces in a DIS exercise. Research into various aspects of CGF systems is ongoing. Several CGF systems have been implemented.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sandoval, M Analisa; Uribe, Eva C; Sandoval, Marisa N
2009-01-01
In 2008 a joint team from Los Alamos National Laboratory (LANL) and Brookhaven National Laboratory (BNL) consisting of specialists in training of IAEA inspectors in the use of complementary access activities formulated a training program to prepare the U.S. Doe laboratories for the entry into force of the Additional Protocol. As a major part of the support of the activity, LANL summer interns provided open source information analysis to the LANL-BNL mock inspection team. They were a part of the Next Generation Safeguards Initiative's (NGSI) summer intern program aimed at producing the next generation of safeguards specialists. This paper describesmore » how they used open source information to 'backstop' the LANL-BNL team's effort to construct meaningful Additional Protocol Complementary Access training scenarios for each of the three DOE laboratories, Lawrence Livermore National Laboratory, Idaho National Laboratory, and Oak Ridge National Laboratory.« less
Development of a neuromuscular electrical stimulation protocol for sprint training.
Russ, David W; Clark, Brian C; Krause, Jodi; Hagerman, Fredrick C
2012-09-01
Sprint training is associated with several beneficial adaptations in skeletal muscle, including an enhancement of sarcoplasmic reticulum (SR) Ca(2+) release. Unfortunately, several patient populations (e.g., the elderly, those with cardiac dysfunction) that might derive great benefit from sprint exercise are unlikely to tolerate it. The purpose of this report was to describe the development of a tolerable neuromuscular electrical stimulation (NMES) protocol that induces skeletal muscle adaptations similar to those observed with sprint training. Our NMES protocol was modeled after a published sprint exercise protocol and used a novel electrode configuration and stimulation sequence to provide adequate training stimulus while maintaining subject tolerance. Nine young, healthy subjects (four men) began and completed the training protocol of the knee extensor muscles. All subjects completed the protocol, with ratings of discomfort far less than those reported in studies of traditional NMES. Training induced significant increases in SR Ca(2+) release and citrate synthase activity (~16% and 32%, respectively), but SR Ca(2+) uptake did not change. The percentage of myosin heavy chain IIx isoform was decreased significantly after training. At the whole muscle level, neither central activation nor maximum voluntary isometric contraction force were significantly altered, although isometric force did exhibit a trend toward an increase (~3%, P = 0.055). Surprisingly, the NMES training produced a significant increase in muscle cross-sectional area (~3%, P = 0.04). It seems that an appropriately designed NMES protocol can mimic many of the benefits of sprint exercise training, with a low overall time commitment and training volume. These findings suggest that NMES has the potential to bring the benefits of sprint exercise to individuals who are unable to tolerate traditional sprint training.
The impact of posture and prolonged cyclic compressive loading on vertebral joint mechanics.
Gooyers, Chad E; McMillan, Robert D; Howarth, Samuel J; Callaghan, Jack P
2012-08-01
An in vitro biomechanics investigation exposing porcine functional spinal units (FSUs) to submaximal cyclic or static compressive forces while in a flexed, neutral, or extended posture. To investigate the combined effect of cyclically applied compressive force (e.g., vibration) and postural deviation on intervertebral joint mechanics. Independently, prolonged vibration exposure and non-neutral postures are known risk factors for development of low back pain and injury. However, there is limited basic scientific evidence to explain how the risk of low back injury from vibration exposure is modified by other mechanical factors. This work examined the influence of static postural deviation on vertebral joint height loss and compressive stiffness under cyclically applied compressive force. Forty-eight FSUs, consisting of 2 adjacent vertebrae, ligaments, and the intervening intervertebral disc were included in the study. Each specimen was randomized to 1 of 3 experimental posture conditions (neutral, flexed, or extended) and assigned to 1 of 2 loading protocols, consisting of (1) cyclic (1500 ± 1200 N applied at 5 Hz using a sinusoidal waveform, resulting in 0.2 g rms acceleration) or (2) 1500 N of static compressive force. RESULTS.: As expected, FSU height loss followed a typical first-order response in both the static and cyclic loading protocols, with the majority (~50%) of the loss occurring in the first 20 minutes of testing. A significant interaction between posture and loading protocol (P < 0.001) was noted in the magnitude of FSU height loss. Subsequent analysis of simple effects revealed significant differences between cyclic and static loading protocols in both a neutral (P = 0.016) and a flexed posture (P < 0.0001). No significant differences (P = 0.320) were noted between pre/postmeasurements of FSU compressive stiffness. Posture is an important mechanical factor to consider when assessing the risk of injury from cyclic loading to the lumbar spine.
Associations of genetic markers in cattle receiving differing implant protocols.
King, D A; Shackelford, S D; McDaneld, T G; Kuehn, L A; Kemp, C M; Smith, T P L; Wheeler, T L; Koohmaraie, M
2012-07-01
The potential interaction of growth-promoting implants and genetic markers previously reported to be associated with growth, carcass traits, and tenderness was evaluated. Two implant protocols were applied to subsets of steers (n = 383) and heifers (n = 65) that were also genotyped for 47 SNP reported to be associated with variation in growth, fat thickness, LM area, marbling, or tenderness. The "mild" protocol consisted of a single terminal implant [16 mg estradiol benzoate (EB), 80 mg trenbalone acetate (TBA) or 8 mg EB, 80 mg TBA given to steers and heifers, respectively]. The "aggressive" protocol consisted of both a growing implant (8 mg EB, 40 mg TBA) for the lightest half of the animals on the aggressive protocol and 2 successive implants (28 mg EB, 200 mg TBA) given to all animals assigned to the aggressive treatment. Implant protocol had measurable impact on BW and ADG (P < 0.05), with the aggressive protocol increasing these traits before the terminal implant (relative to the mild protocol), whereas the mild protocol increased ADG after the terminal implant so that the final BW and ADG over the experimental period were similar between protocols. Animals on the aggressive protocol had significantly increased (P < 0.05) LM area (1.9 cm(2)), slice shear force (1.4 kg), and intact desmin (0.05 units), but decreased (P < 0.05) marbling score (49 units) and adjusted fat thickness (0.1 cm), and yield grade (0.15 units). Among both treatments, 8 of 9 growth-related SNP were associated with BW or ADG, and 6 of 17 tenderness-related SNP were associated with slice shear force or intact desmin. Favorable growth alleles generally were associated with increased carcass yield traits but decreased tenderness. Similarly, favorable tenderness genotypes for some markers were associated with decreased BW and ADG. Some interactions of implant protocol and genotype were noted, with some growth SNP alleles increasing the effect of the aggressive protocol. In contrast, putative beneficial effects of favorable tenderness SNP alleles were mitigated by the effects of aggressive implant. These type of antagonisms of management variables and genotypes must be accounted for in marker assisted selection (MAS) programs, and our results suggest that MAS could be used to manage, but likely will not eliminate negative impact of implants on quality.
Rymer, William Z.; Beer, Randall F.
2012-01-01
Previous studies using advanced matrix factorization techniques have shown that the coordination of human voluntary limb movements may be accomplished using combinations of a small number of intermuscular coordination patterns, or muscle synergies. However, the potential use of muscle synergies for isometric force generation has been evaluated mostly using correlational methods. The results of such studies suggest that fixed relationships between the activations of pairs of muscles are relatively rare. There is also emerging evidence that the nervous system uses independent strategies to control movement and force generation, which suggests that one cannot conclude a priori that isometric force generation is accomplished by combining muscle synergies, as shown in movement control. In this study, we used non-negative matrix factorization to evaluate the ability of a few muscle synergies to reconstruct the activation patterns of human arm muscles underlying the generation of three-dimensional (3-D) isometric forces at the hand. Surface electromyographic (EMG) data were recorded from eight key elbow and shoulder muscles during 3-D force target-matching protocols performed across a range of load levels and hand positions. Four synergies were sufficient to explain, on average, 95% of the variance in EMG datasets. Furthermore, we found that muscle synergy composition was conserved across biomechanical task conditions, experimental protocols, and subjects. Our findings are consistent with the view that the nervous system can generate isometric forces by assembling a combination of a small number of muscle synergies, differentially weighted according to task constraints. PMID:22279190
1999-12-01
compression technology . The ubiquity of routed Internet Protocol (IP) networks, and the desire to trim telephony costs are the major driving forces of the...mid- s, data and voice began to merge, propelled by advances in compression technology . The ubiquity of routed Internet Protocol (IP) networks...transmit voice over IP networks that are privately owned or publicly utilized. If we have the technology to transmit Voice over the Internet then why not
Information Assurance within the United States Air Force
ERIC Educational Resources Information Center
Cherry, John D.
2010-01-01
According to the Department of Defense (DoD), a review of information assurance (IA) in the United States Air Force (USAF) in 2009, cyber security is jeopardized because of information loss. This situation has occurred in large part because of less than optimal training practices or adherence to training protocols. The purpose of this study was…
2007-03-01
provides a means for anyone who has access to an Internet connection to collect or disseminate information on a global scale at a very low cost. The......AIR UNIVERSITY AIR FORCE INSTITUTE OF TECHNOLOGY Wright-Patterson Air Force Base, Ohio APPROVED FOR PUBLIC RELEASE; DISTRIBUTION UNLIMITED
Quantum fluctuation theorems and generalized measurements during the force protocol
NASA Astrophysics Data System (ADS)
Watanabe, Gentaro; Venkatesh, B. Prasanna; Talkner, Peter; Campisi, Michele; Hänggi, Peter
2014-03-01
Generalized measurements of an observable performed on a quantum system during a force protocol are investigated and conditions that guarantee the validity of the Jarzynski equality and the Crooks relation are formulated. In agreement with previous studies by M. Campisi, P. Talkner, and P. Hänggi [Phys. Rev. Lett. 105, 140601 (2010), 10.1103/PhysRevLett.105.140601; Phys. Rev. E 83, 041114 (2011), 10.1103/PhysRevE.83.041114], we find that these fluctuation relations are satisfied for projective measurements; however, for generalized measurements special conditions on the operators determining the measurements need to be met. For the Jarzynski equality to hold, the measurement operators of the forward protocol must be normalized in a particular way. The Crooks relation additionally entails that the backward and forward measurement operators depend on each other. Yet, quite some freedom is left as to how the two sets of operators are interrelated. This ambiguity is removed if one considers selective measurements, which are specified by a joint probability density function of work and measurement results of the considered observable. We find that the respective forward and backward joint probabilities satisfy the Crooks relation only if the measurement operators of the forward and backward protocols are the time-reversed adjoints of each other. In this case, the work probability density function conditioned on the measurement result satisfies a modified Crooks relation. The modification appears as a protocol-dependent factor that can be expressed by the information gained by the measurements during the forward and backward protocols. Finally, detailed fluctuation theorems with an arbitrary number of intervening measurements are obtained.
Design of a novel telerehabilitation system with a force-sensing mechanism.
Zhang, Songyuan; Guo, Shuxiang; Gao, Baofeng; Hirata, Hideyuki; Ishihara, Hidenori
2015-05-19
Many stroke patients are expected to rehabilitate at home, which limits their access to proper rehabilitation equipment, treatment, or assessment by therapists. We have developed a novel telerehabilitation system that incorporates a human-upper-limb-like device and an exoskeleton device. The system is designed to provide the feeling of real therapist-patient contact via telerehabilitation. We applied the principle of a series elastic actuator to both the master and slave devices. On the master side, the therapist can operate the device in a rehabilitation center. When performing passive training, the master device can detect the therapist's motion while controlling the deflection of elastic elements to near-zero, and the patient can receive the motion via the exoskeleton device. When performing active training, the design of the force-sensing mechanism in the master device can detect the assisting force added by the therapist. The force-sensing mechanism also allows force detection with an angle sensor. Patients' safety is guaranteed by monitoring the motor's current from the exoskeleton device. To compensate for any possible time delay or data loss, a torque-limiter mechanism was also designed in the exoskeleton device for patients' safety. Finally, we successfully performed a system performance test for passive training with transmission control protocol/internet protocol communication.
Design of a Novel Telerehabilitation System with a Force-Sensing Mechanism
Zhang, Songyuan; Guo, Shuxiang; Gao, Baofeng; Hirata, Hideyuki; Ishihara, Hidenori
2015-01-01
Many stroke patients are expected to rehabilitate at home, which limits their access to proper rehabilitation equipment, treatment, or assessment by therapists. We have developed a novel telerehabilitation system that incorporates a human-upper-limb-like device and an exoskeleton device. The system is designed to provide the feeling of real therapist–patient contact via telerehabilitation. We applied the principle of a series elastic actuator to both the master and slave devices. On the master side, the therapist can operate the device in a rehabilitation center. When performing passive training, the master device can detect the therapist’s motion while controlling the deflection of elastic elements to near-zero, and the patient can receive the motion via the exoskeleton device. When performing active training, the design of the force-sensing mechanism in the master device can detect the assisting force added by the therapist. The force-sensing mechanism also allows force detection with an angle sensor. Patients’ safety is guaranteed by monitoring the motor’s current from the exoskeleton device. To compensate for any possible time delay or data loss, a torque-limiter mechanism was also designed in the exoskeleton device for patients’ safety. Finally, we successfully performed a system performance test for passive training with transmission control protocol/internet protocol communication. PMID:25996511
Jaatinen, Leena; Young, Eleanore; Hyttinen, Jari; Vörös, János; Zambelli, Tomaso; Demkó, László
2016-03-20
This study presents the effect of external electric current on the cell adhesive and mechanical properties of the C2C12 mouse myoblast cell line. Changes in cell morphology, viability, cytoskeleton, and focal adhesion structure were studied by standard staining protocols, while single-cell force spectroscopy based on the fluidic force microscopy technology provided a rapid, serial quantification and detailed analysis of cell adhesion and its dynamics. The setup allowed measurements of adhesion forces up to the μN range, and total detachment distances over 40 μm. Force-distance curves have been fitted with a simple elastic model including a cell detachment protocol in order to estimate the Young's modulus of the cells, as well as to reveal changes in the dynamic properties as functions of the applied current dose. While the cell spreading area decreased monotonously with increasing current doses, small current doses resulted only in differences related to cell elasticity. Current doses above 11 As/m(2), however, initiated more drastic changes in cell morphology, viability, cellular structure, as well as in properties related to cell adhesion. The observed differences, eventually leading to cell death toward higher doses, might originate from both the decrease in pH and the generation of reactive oxygen species.
Simpson, Jeffrey D; DeBusk, Hunter; Hill, Christopher; Knight, Adam; Chander, Harish
2018-03-01
Ankle sprains are a common orthopedic injury in military populations, which may be attributed to occupational demands and footwear. Minimalist military boots have become popular, but their influence on ground reaction force (GRF) attenuation capabilities during an ankle inversion perturbation are unknown. Therefore, the purpose of this study was to examine potential differences in GRFs during an ankle inversion perturbation in a standard issue (STN) and minimalist military boot (MIN) before and after a simulated military workload. Twenty-one healthy adult males completed an ankle inversion perturbation protocol in each footwear condition before and after an incremental treadmill exercise protocol to volitional exhaustion while wearing a 16kg rucksack. The ankle inversion perturbation protocol consisted of stepping down from a 27cm box onto a force platform with a fulcrum (FUL), which created 25° of inversion upon landing, or flat (FLT) outer sole attached to the plantar aspect of the participants' footwear in random order. Peak vertical, anterior/posterior, and medial/lateral components of the GRF during FUL and FLT conditions were assessed, normalized to multiples of body weight in each footwear. Dependent variables were then analyzed using separate 2 (footwear)×2 (time) repeated measures ANOVA (p<0.05). The MIN footwear demonstrated significantly greater vertical GRF and significantly less medial GRF during the FUL condition. These results indicate that various mechanical and design characteristics of military footwear may influence GRF attenuation capabilities and ankle joint loading when the foot/ankle complex is forced into inversion. Copyright © 2017 Elsevier Ltd. All rights reserved.
Mellors, L J; Gibbs, C L; Barclay, C J
2001-05-01
The results of previous studies suggest that the maximum mechanical efficiency of rat papillary muscles is lower during a contraction protocol involving sinusoidal length changes than during one involving afterloaded isotonic contractions. The aim of this study was to compare directly the efficiency of isolated rat papillary muscle preparations in isotonic and sinusoidal contraction protocols. Experiments were performed in vitro (27 degrees C) using left ventricular papillary muscles from adult rats. Each preparation performed three contraction protocols: (i) low-frequency afterloaded isotonic contractions (10 twitches at 0.2 Hz), (ii) sinusoidal length change contractions with phasic stimulation (40 twitches at 2 Hz) and (iii) high-frequency afterloaded isotonic contractions (40 twitches at 2 Hz). The first two protocols resembled those used in previous studies and the third combined the characteristics of the first two. The parameters for each protocol were adjusted to those that gave maximum efficiency. For the afterloaded isotonic protocols, the afterload was set to 0.3 of the maximum developed force. The sinusoidal length change protocol incorporated a cycle amplitude of +/-5% resting length and a stimulus phase of -10 degrees. Measurements of force output, muscle length change and muscle temperature change were used to calculate the work and heat produced during and after each protocol. Net mechanical efficiency was defined as the proportion of the energy (enthalpy) liberated by the muscle that appeared as work. The efficiency in the low-frequency, isotonic contraction protocol was 21.1+/-1.4% (mean +/- s.e.m., N=6) and that in the sinusoidal protocol was 13.2+/-0.7%, consistent with previous results. This difference was not due to the higher frequency or greater number of twitches because efficiency in the high-frequency, isotonic protocol was 21.5+/-1.0%. Although these results apparently confirm that efficiency is protocol-dependent, additional experiments designed to measure work output unambiguously indicated that the method used to calculate work output in isotonic contractions overestimated actual work output. When net work output, which excludes work done by parallel elastic elements, rather than total work output was used to determine efficiency in afterloaded isotonic contractions, efficiency was similar to that for sinusoidal contractions. The maximum net mechanical efficiency of rat papillary muscles performing afterloaded isotonic or sinusoidal length change contractions was between 10 and 15%.
Sung, Jongmin; Nag, Suman; Mortensen, Kim I; Vestergaard, Christian L; Sutton, Shirley; Ruppel, Kathleen; Flyvbjerg, Henrik; Spudich, James A
2015-08-04
Molecular motors are responsible for numerous cellular processes from cargo transport to heart contraction. Their interactions with other cellular components are often transient and exhibit kinetics that depend on load. Here, we measure such interactions using 'harmonic force spectroscopy'. In this method, harmonic oscillation of the sample stage of a laser trap immediately, automatically and randomly applies sinusoidally varying loads to a single motor molecule interacting with a single track along which it moves. The experimental protocol and the data analysis are simple, fast and efficient. The protocol accumulates statistics fast enough to deliver single-molecule results from single-molecule experiments. We demonstrate the method's performance by measuring the force-dependent kinetics of individual human β-cardiac myosin molecules interacting with an actin filament at physiological ATP concentration. We show that a molecule's ADP release rate depends exponentially on the applied load, in qualitative agreement with cardiac muscle, which contracts with a velocity inversely proportional to external load.
Cyber-physical experiments on the efficiency of swimming protocols
NASA Astrophysics Data System (ADS)
Wei, Nathaniel; Floryan, Daniel; van Buren, Tyler; Smits, Alexander
2016-11-01
We present results from experiments on a biologically inspired cyber-physical system, composed of a two-dimensional heaving and pitching rigid airfoil attached to a six component load cell, mounted to a traverse that can move along a water channel. A feedback controller, influenced by the apparatus of Mackowski and Williamson, introduces the effects of a fictional drag force specified by a virtual body profile and drives the traverse accordingly. Free-swimming protocols using the force-feedback system are compared with similar motions on a motionless traverse. The propulsive efficiency of burst-and-coast kinematics is also considered. Of particular interest are (1) the implementation of the cyber-physical control system with respect to the accessible experimental parameter space, (2) the impact of force-based streamwise actuation on experimental data, and (3) the effects of burst-and-coast motions on propulsive efficiency. The work was supported by the Office of Naval Research (ONR) under MURI Grant N00014-14-1-0533.
Sung, Jongmin; Nag, Suman; Mortensen, Kim I.; Vestergaard, Christian L.; Sutton, Shirley; Ruppel, Kathleen; Flyvbjerg, Henrik; Spudich, James A.
2015-01-01
Molecular motors are responsible for numerous cellular processes from cargo transport to heart contraction. Their interactions with other cellular components are often transient and exhibit kinetics that depend on load. Here, we measure such interactions using ‘harmonic force spectroscopy'. In this method, harmonic oscillation of the sample stage of a laser trap immediately, automatically and randomly applies sinusoidally varying loads to a single motor molecule interacting with a single track along which it moves. The experimental protocol and the data analysis are simple, fast and efficient. The protocol accumulates statistics fast enough to deliver single-molecule results from single-molecule experiments. We demonstrate the method's performance by measuring the force-dependent kinetics of individual human β-cardiac myosin molecules interacting with an actin filament at physiological ATP concentration. We show that a molecule's ADP release rate depends exponentially on the applied load, in qualitative agreement with cardiac muscle, which contracts with a velocity inversely proportional to external load. PMID:26239258
Shimamoto, Yuta; Kapoor, Tarun M.
2014-01-01
SUMMARY To explain how micron-sized cellular structures generate and respond to forces we need to characterize their micromechanical properties. Here we provide a protocol to build and use a dual force-calibrated microneedle-based set-up to quantitatively analyze the micromechanics of a metaphase spindle assembled in Xenopus laevis egg extracts. This cell-free extract system allows for controlled biochemical perturbations of spindle components. We describe how the microneedles are prepared and how they can be used to apply and measure forces. A multi-mode imaging system allows tracking of microtubules, chromosomes and needle tips. This set-up can be used to analyze the viscoelastic properties of the spindle on time-scales ranging from minutes to sub-seconds. A typical experiment, along with data analysis, is also detailed. We anticipate that our protocol can be readily extended to analyze the micromechanics of other cellular structures assembled in cell-free extracts. The entire procedure can take 3-4 days. PMID:22538847
Repurposing a Benchtop Centrifuge for High-Throughput Single-Molecule Force Spectroscopy.
Yang, Darren; Wong, Wesley P
2018-01-01
We present high-throughput single-molecule manipulation using a benchtop centrifuge, overcoming limitations common in other single-molecule approaches such as high cost, low throughput, technical difficulty, and strict infrastructure requirements. An inexpensive and compact Centrifuge Force Microscope (CFM) adapted to a commercial centrifuge enables use by nonspecialists, and integration with DNA nanoswitches facilitates both reliable measurements and repeated molecular interrogation. Here, we provide detailed protocols for constructing the CFM, creating DNA nanoswitch samples, and carrying out single-molecule force measurements.
Multimedia-Based Integration of Cross-Layer Techniques
2014-06-01
wireless networks play a critical role in net-centric warfare, including the sharing of the time-sensitive battlefield information among military nodes for...layer protocols are key enablers in effectively deploying the military wireless network. This report discusses the design of cross-layer protocols...2 1.0 INTRODUCTION 1.1 Motivation The Air Force (AF) Wireless Networks (also denoted as military networks in this report) must be capable of
From Fob to Noc: A Pathway to a Cyber Career for Combat Veterans
2014-06-01
Assurance Certifications GS general schedule HSAC Homeland Security Advisory Council IDS intrusion detection system IP internet protocol IPS...NIPRNET non-secure internet protocol router network NIST National Institute for Standards and Technology NOC network operations center NSA National...twice a day on an irregular schedule or during contact with the enemy to keep any observing enemy wary of the force protection 13 condition at any
Harrison, C H; Laussen, P C
2008-05-01
Donation after cardiac death (DCD) remains controversial in some pediatric institutions. An evidence-based, consensus-building approach to setting institutional policy about DCD can address the controversy openly and identify common ground. To resolve an extended internal debate regarding DCD policy at Children's Hospital Boston, a multidisciplinary task force was commissioned to engage in fact finding and deliberations about clinical and ethical issues in pediatric DCD, and attempt to reach consensus regarding the development of a protocol for pediatric DCD. Issues examined included values and attitudes of staff, families, and the public; number of possible candidates for DCD at the hospital; risks and benefits for child donors and their families; and research needs. Consensus was reached on a set of foundational ethical principles for pediatric DCD. With assistance from the local organ procurement organization (OPO), the task force developed a protocol for pediatric kidney DCD which most members believed could meet all the requirements of the foundational ethical principles. Complete consensus on the use of the protocol was not reached; however, almost all members supported initiation of kidney DCD for older pediatric patients who had wished to be organ donors. The hospital has implemented the protocol on this limited basis and established a process for considering proposals to expand the eligible donor population and include other organs.
Fatigue and muscle-tendon stiffness after stretch-shortening cycle and isometric exercise.
Toumi, Hechmi; Poumarat, Georges; Best, Thomas M; Martin, Alain; Fairclough, John; Benjamin, Mike
2006-10-01
The purpose of the present study was to compare vertical jump performance after 2 different fatigue protocols. In the first protocol, subjects performed consecutive sets of 10 repetitions of stretch-shortening cycle (SSC) contractions. In the second protocol, successive sets of 10 repetitions of isometric contractions were performed for 10 s with the knee at 90 degrees of flexion. The exercises were stopped when the subjects failed to reach 50% of their maximum voluntary isometric contractions. Maximal isometric force and maximal concentric power were assessed by performing supine leg presses, squat jumps, and drop jumps. Surface EMG was used to determine changes in muscle activation before and after fatigue. In both groups, the fatigue exercises reduced voluntary isometric force, maximal concentric power, and drop jump performance. Kinematic data showed a decrease in knee muscle-tendon stiffness accompanied by a lengthened ground contact time. EMG analysis showed that the squat and drop jumps were performed similarly before and after the fatigue exercise for both groups. Although it was expected that the stiffness would decrease more after SSC than after isometric fatigue (as a result of a greater alteration of the reflex sensitivity SSC), our results showed that both protocols had a similar effect on knee muscle stiffness during jumping exercises. Both fatigue protocols induced muscle fatigue, and the decrease in jump performance was linked to a decrease in the strength and stiffness of the knee extensor muscles.
Synchrony and desynchrony in circadian clocks: impacts on learning and memory
Krishnan, Harini C.
2015-01-01
Circadian clocks evolved under conditions of environmental variation, primarily alternating light dark cycles, to enable organisms to anticipate daily environmental events and coordinate metabolic, physiological, and behavioral activities. However, modern lifestyle and advances in technology have increased the percentage of individuals working in phases misaligned with natural circadian activity rhythms. Endogenous circadian oscillators modulate alertness, the acquisition of learning, memory formation, and the recall of memory with examples of circadian modulation of memory observed across phyla from invertebrates to humans. Cognitive performance and memory are significantly diminished when occurring out of phase with natural circadian rhythms. Disruptions in circadian regulation can lead to impairment in the formation of memories and manifestation of other cognitive deficits. This review explores the types of interactions through which the circadian clock modulates cognition, highlights recent progress in identifying mechanistic interactions between the circadian system and the processes involved in memory formation, and outlines methods used to remediate circadian perturbations and reinforce circadian adaptation. PMID:26286653
Oxyntomodulin regulates resetting of the liver circadian clock by food
Landgraf, Dominic; Tsang, Anthony H; Leliavski, Alexei; Koch, Christiane E; Barclay, Johanna L; Drucker, Daniel J; Oster, Henrik
2015-01-01
Circadian clocks coordinate 24-hr rhythms of behavior and physiology. In mammals, a master clock residing in the suprachiasmatic nucleus (SCN) is reset by the light–dark cycle, while timed food intake is a potent synchronizer of peripheral clocks such as the liver. Alterations in food intake rhythms can uncouple peripheral clocks from the SCN, resulting in internal desynchrony, which promotes obesity and metabolic disorders. Pancreas-derived hormones such as insulin and glucagon have been implicated in signaling mealtime to peripheral clocks. In this study, we identify a novel, more direct pathway of food-driven liver clock resetting involving oxyntomodulin (OXM). In mice, food intake stimulates OXM secretion from the gut, which resets liver transcription rhythms via induction of the core clock genes Per1 and 2. Inhibition of OXM signaling blocks food-mediated resetting of hepatocyte clocks. These data reveal a direct link between gastric filling with food and circadian rhythm phasing in metabolic tissues. DOI: http://dx.doi.org/10.7554/eLife.06253.001 PMID:25821984
NASA Astrophysics Data System (ADS)
Ménégoz, M.; Bilbao, R.; Bellprat, O.; Guemas, V.; Doblas-Reyes, F. J.
2018-06-01
The last major volcanic eruptions, the Agung in 1963, El Chichon in 1982 and Pinatubo in 1991, were each associated with a cooling of the troposphere that has been observed over large continental areas and over the Western Pacific, the Indian Ocean and the Southern Atlantic. Simultaneously, Eastern tropical Pacific temperatures increased due to prevailing El Niño conditions. Here we show that the pattern of these near-surface temperature anomalies is partly reproduced with decadal simulations of the EC-Earth model initialised with climate observations and forced with an estimate of the observed volcanic aerosol optical thickness. Sensitivity experiments highlight a cooling induced by the volcanic forcing, whereas El Niño events following the eruptions would have occurred even without volcanic eruptions. Focusing on the period 1961–2001, the main source of skill of this decadal forecast system during the first 2 years is related to the initialisation of the model. The contribution of the initialisation to the skill becomes smaller than the contribution of the volcanic forcing after two years, the latter being substantial in the Western Pacific, the Indian Ocean and the Western Atlantic. Two simple protocols for real time forecasts are investigated: using the forcing of a past volcanic eruption to simulate the forcing of a new one, and applying a two-year exponential decay to the initial stratospheric aerosol load observed at the beginning of the forecast. This second protocol applied in retrospective forecasts allows a partial reproduction of the skill attained with observed forcing.
NASA Technical Reports Server (NTRS)
Jewett, M. E.; Kronauer, R. E.; Brown, E. N. (Principal Investigator)
1998-01-01
In 1990, Kronauer proposed a mathematical model of the effects of light on the human circadian pacemaker. Although this model predicted many general features of the response of the human circadian pacemaker to light exposure, additional data now available enable us to refine the original model. We first refined the original model by incorporating the results of a dose response curve to light into the model's predicted relationship between light intensity and the strength of the drive onto the pacemaker. Data from three bright light phase resetting experiments were then used to refine the amplitude recovery characteristics of the model. Finally, the model was tested and further refined using data from an extensive phase resetting experiment in which a 3-cycle bright light stimulus was presented against a background of dim light. In order to describe the results of the four resetting experiments, the following major refinements to the original model were necessary: (i) the relationship between light intensity (I) and drive onto the pacemaker was reduced from I1/3 to I0.23 for light levels between 150 and 10,000 lux; (ii) the van der Pol oscillator from the original model was replaced with a higher-order limit cycle oscillator so that amplitude recovery is slower near the singularity and faster near the limit cycle; (iii) a direct effect of light on circadian period (tau x) was incorporated into the model such that as I increases, tau x decreases, which is in accordance with "Aschoff's rule". This refined model generates the following testable predictions: it should be difficult to enhance normal circadian amplitude via bright light; near the critical point of a type 0 phase response curve (PRC) the slope should be steeper than it is in a type 1 PRC; and circadian period measured during forced desynchrony should be directly affected by ambient light intensity.
Fast equilibration protocol for million atom systems of highly entangled linear polyethylene chains
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sliozberg, Yelena R.; TKC Global, Inc., Aberdeen Proving Ground, Maryland 21005; Kröger, Martin
Equilibrated systems of entangled polymer melts cannot be produced using direct brute force equilibration due to the slow reptation dynamics exhibited by high molecular weight chains. Instead, these dense systems are produced using computational techniques such as Monte Carlo-Molecular Dynamics hybrid algorithms, though the use of soft potentials has also shown promise mainly for coarse-grained polymeric systems. Through the use of soft-potentials, the melt can be equilibrated via molecular dynamics at intermediate and long length scales prior to switching to a Lennard-Jones potential. We will outline two different equilibration protocols, which use various degrees of information to produce the startingmore » configurations. In one protocol, we use only the equilibrium bond angle, bond length, and target density during the construction of the simulation cell, where the information is obtained from available experimental data and extracted from the force field without performing any prior simulation. In the second protocol, we moreover utilize the equilibrium radial distribution function and dihedral angle distribution. This information can be obtained from experimental data or from a simulation of short unentangled chains. Both methods can be used to prepare equilibrated and highly entangled systems, but the second protocol is much more computationally efficient. These systems can be strictly monodisperse or optionally polydisperse depending on the starting chain distribution. Our protocols, which utilize a soft-core harmonic potential, will be applied for the first time to equilibrate a million particle system of polyethylene chains consisting of 1000 united atoms at various temperatures. Calculations of structural and entanglement properties demonstrate that this method can be used as an alternative towards the generation of entangled equilibrium structures.« less
Excessive training impairs the insulin signal transduction in mice skeletal muscles.
Pereira, Bruno C; da Rocha, Alisson L; Pinto, Ana P; Pauli, José R; de Moura, Leandro P; Mekary, Rania A; de Freitas, Ellen C; da Silva, Adelino S R
2016-07-01
The main aim of this investigation was to verify the effects of overtraining (OT) on the insulin and inflammatory signaling pathways in mice skeletal muscles. Rodents were divided into control (CT), overtrained by downhill running (OTR/down), overtrained by uphill running (OTR/up), and overtrained by running without inclination (OTR) groups. Rotarod, incremental load, exhaustive, and grip force tests were used to evaluate performance. Thirty-six hours after the grip force test, the extensor digitorum longus (EDL) and soleus were extracted for subsequent protein analyses. The three OT protocols led to similar responses of all performance evaluation tests. The phosphorylation of insulin receptor beta (pIRβ; Tyr), protein kinase B (pAkt; Ser473), and the protein levels of plasma membrane glucose transporter-4 (GLUT4) were lower in the EDL and soleus after the OTR/down protocol and in the soleus after the OTR/up and OTR protocols. While the pIRβ was lower after the OTR/up and OTR protocols, the pAkt was higher after the OTR/up in the EDL. The phosphorylation of IκB kinase alpha and beta (pIKKα/β; Ser180/181), stress-activated protein kinases/Jun amino-terminal kinases (pSAPK-JNK; Thr183/Tyr185), factor nuclear kappa B (pNFκB p65; Ser536), and insulin receptor substrate 1 (pIRS1; Ser307) were higher after the OTR/down protocol, but were not altered after the two other OT protocols. In summary, these data suggest that OT may lead to skeletal muscle insulin signaling pathway impairment, regardless of the predominance of eccentric contractions, although the insulin signal pathway impairment induced in OTR/up and OTR appeared to be muscle fiber-type specific. © 2016 Society for Endocrinology.
Update of the ATTRACT force field for the prediction of protein-protein binding affinity.
Chéron, Jean-Baptiste; Zacharias, Martin; Antonczak, Serge; Fiorucci, Sébastien
2017-06-05
Determining the protein-protein interactions is still a major challenge for molecular biology. Docking protocols has come of age in predicting the structure of macromolecular complexes. However, they still lack accuracy to estimate the binding affinities, the thermodynamic quantity that drives the formation of a complex. Here, an updated version of the protein-protein ATTRACT force field aiming at predicting experimental binding affinities is reported. It has been designed on a dataset of 218 protein-protein complexes. The correlation between the experimental and predicted affinities reaches 0.6, outperforming most of the available protocols. Focusing on a subset of rigid and flexible complexes, the performance raises to 0.76 and 0.69, respectively. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.
Improvement of isometric dorsiflexion protocol for assessment of tibialis anterior muscle strength.
Siddiqi, Ariba; Arjunan, Sridhar P; Kumar, Dinesh
2015-01-01
It is important to accurately estimate the electromyogram (EMG)/force relationship of triceps surae (TS) muscle for detecting strength deficit of tibalis anterior (TA) muscle. In literature, the protocol for recording EMG and force of dorsiflexion have been described, and the necessity for immobilizing the ankle has been explained. However, there is a significant variability of the results among researchers even though they report the fixation of the ankle. We have determined that toe extension can cause significant variation in the dorsiflexion force and EMG of TS and this can occur despite following the current guidelines which require immobilizing the ankle. The results also show that there was a large increase in the variability of the force and the RMS of EMG of TS when the toes were not strapped compared with when they were strapped. Thus, with the current guidelines, where there are no instructions regarding the necessity of strapping the toes, the EMG/force relationship of TS could be incorrect and give an inaccurate assessment of the dorsiflexor TA strength. In summary, •Current methodology to estimate the dorsiflexor TA strength with respect to the TS activity, emphasizing on ankle immobilization is insufficient to prevent large variability in the measurements.•Toe extension during dorsiflexion was found to be one source of variability in estimating the TA strength.•It is recommended that guidelines for recording force and EMG from TA and TS muscles should require the strapping of the toes along with the need for immobilizing the ankle.
Cost and Precision of Brownian Clocks
NASA Astrophysics Data System (ADS)
Barato, Andre C.; Seifert, Udo
2016-10-01
Brownian clocks are biomolecular networks that can count time. A paradigmatic example are proteins that go through a cycle, thus regulating some oscillatory behavior in a living system. Typically, such a cycle requires free energy often provided by ATP hydrolysis. We investigate the relation between the precision of such a clock and its thermodynamic costs. For clocks driven by a constant thermodynamic force, a given precision requires a minimal cost that diverges as the uncertainty of the clock vanishes. In marked contrast, we show that a clock driven by a periodic variation of an external protocol can achieve arbitrary precision at arbitrarily low cost. This result constitutes a fundamental difference between processes driven by a fixed thermodynamic force and those driven periodically. As a main technical tool, we map a periodically driven system with a deterministic protocol to one subject to an external protocol that changes in stochastic time intervals, which simplifies calculations significantly. In the nonequilibrium steady state of the resulting bipartite Markov process, the uncertainty of the clock can be deduced from the calculable dispersion of a corresponding current.
Protocol and the post-human performativity of security techniques
O’Grady, Nathaniel
2015-01-01
This article explores the deployment of exercises by the United Kingdom Fire and Rescue Service. Exercises stage, simulate and act out potential future emergencies and in so doing help the Fire and Rescue Service prepare for future emergencies. Specifically, exercises operate to assess and develop protocol; sets of guidelines which plan out the actions undertaken by the Fire and Rescue Service in responding to a fire. In the article I outline and assess the forms of knowledge and technologies, what I call the ‘aesthetic forces’, by which the exercise makes present and imagines future emergencies. By critically engaging with Karen Barad’s notion of post-human performativity, I argue that exercises provide a site where such forces can entangle with one another; creating a bricolage through which future emergencies are evoked sensually and representatively, ultimately making it possible to experience emergencies in the present. This understanding of exercises allows also for critical appraisal of protocol both as phenomena that are produced through the enmeshing of different aesthetic forces and as devices which premise the operation of the security apparatus on contingency. PMID:29708110
A Murine Model of Robotic Training to Evaluate Skeletal Muscle Recovery after Injury.
Lai, Stefano; Panarese, Alessandro; Lawrence, Ross; Boninger, Michael L; Micera, Silvestro; Ambrosio, Fabrisia
2017-04-01
In vivo studies have suggested that motor exercise can improve muscle regeneration after injury. Nevertheless, preclinical investigations still lack reliable tools to monitor motor performance over time and to deliver optimal training protocols to maximize force recovery. Here, we evaluated the utility of a murine robotic platform (i) to detect early impairment and longitudinal recovery after acute skeletal muscle injury and (ii) to administer varying intensity training protocols to enhance forelimb motor performance. A custom-designed robotic platform was used to train mice to perform a forelimb retraction task. After an acute injury to bilateral biceps brachii muscles, animals performed a daily training protocol in the platform at high (HL) or low (LL) loading levels over the course of 3 wk. Control animals were not trained (NT). Motor performance was assessed by quantifying force, time, submovement count, and number of movement attempts to accomplish the task. Myofiber number and cross-sectional area at the injury site were quantified histologically. Two days after injury, significant differences in the time, submovement count, number of movement attempts, and exerted force were observed in all mice, as compared with baseline values. Interestingly, the recovery time of muscle force production differed significantly between intervention groups, with HL group showing a significantly accelerated recovery. Three weeks after injury, all groups showed motor performance comparable with baseline values. Accordingly, there were no differences in the number of myofibers or average cross-sectional area among groups after 3 wk. Our findings demonstrate the utility of our custom-designed robotic device for the quantitative assessment of skeletal muscle function in preclinical murine studies. Moreover, we demonstrate that this device may be used to apply varying levels of resistance longitudinally as a means manipulate physiological muscle responses.
Tera-node Network Technology (Task 3) Scalable Personal Telecommunications
2000-03-14
Simulation results of this work may be found in http://north.east.isi.edu/spt/ audio.html. 6. Internet Research Task Force Reliable Multicast...Adaptation, 4. Multimedia Proxy Caching, 5. Experiments with the Rate Adaptation Protocol (RAP) 6. Providing leadership and innovation to the Internet ... Research Task Force (IRTF) Reliable Multicast Research Group (RMRG) 1. End-to-end Architecture for Quality-adaptive Streaming Applications over the
NASA Astrophysics Data System (ADS)
Phister, P. W., Jr.
1983-12-01
Development of the Air Force Institute of Technology's Digital Engineering Laboratory Network (DELNET) was continued with the development of an initial draft of a protocol standard for all seven layers as specified by the International Standards Organization's (ISO) Reference Model for Open Systems Interconnections. This effort centered on the restructuring of the Network Layer to perform Datagram routing and to conform to the developed protocol standards and actual software module development of the upper four protocol layers residing within the DELNET Monitor (Zilog MCZ 1/25 Computer System). Within the guidelines of the ISO Reference Model the Transport Layer was developed utilizing the Internet Header Format (IHF) combined with the Transport Control Protocol (TCP) to create a 128-byte Datagram. Also a limited Application Layer was created to pass the Gettysburg Address through the DELNET. This study formulated a first draft for the DELNET Protocol Standard and designed, implemented, and tested the Network, Transport, and Application Layers to conform to these protocol standards.
Choukroun, J; Ghanaati, S
2018-02-01
The aim of this study was to analyze systematically the influence of the relative centrifugation force (RCF) on leukocytes, platelets and growth factor release within fluid platelet-rich fibrin matrices (PRF). Systematically using peripheral blood from six healthy volunteers, the RCF was reduced four times for each of the three experimental protocols (I-III) within the spectrum (710-44 g), while maintaining a constant centrifugation time. Flow cytometry was applied to determine the platelets and leukocyte number. The growth factor concentration was quantified 1 and 24 h after clotting using ELISA. Reducing RCF in accordance with protocol-II (177 g) led to a significantly higher platelets and leukocytes numbers compared to protocol-I (710 g). Protocol-III (44 g) showed a highly significant increase of leukocytes and platelets number in comparison to -I and -II. The growth factors' concentration of VEGF and TGF-β1 was significantly higher in protocol-II compared to -I, whereas protocol-III exhibited significantly higher growth factor concentration compared to protocols-I and -II. These findings were observed among 1 and 24 h after clotting, as well as the accumulated growth factor concentration over 24 h. Based on the results, it has been demonstrated that it is possible to enrich PRF-based fluid matrices with leukocytes, platelets and growth factors by means of a single alteration of the centrifugation settings within the clinical routine. We postulate that the so-called low speed centrifugation concept (LSCC) selectively enriches leukocytes, platelets and growth factors within fluid PRF-based matrices. Further studies are needed to evaluate the effect of cell and growth factor enrichment on wound healing and tissue regeneration while comparing blood concentrates gained by high and low RCF.
Taxonomy based analysis of force exchanges during object grasping and manipulation
Martin-Brevet, Sandra; Jarrassé, Nathanaël; Burdet, Etienne
2017-01-01
The flexibility of the human hand in object manipulation is essential for daily life activities, but remains relatively little explored with quantitative methods. On the one hand, recent taxonomies describe qualitatively the classes of hand postures for object grasping and manipulation. On the other hand, the quantitative analysis of hand function has been generally restricted to precision grip (with thumb and index opposition) during lifting tasks. The aim of the present study is to fill the gap between these two kinds of descriptions, by investigating quantitatively the forces exerted by the hand on an instrumented object in a set of representative manipulation tasks. The object was a parallelepiped object able to measure the force exerted on the six faces and its acceleration. The grasping force was estimated from the lateral force and the unloading force from the bottom force. The protocol included eleven tasks with complementary constraints inspired by recent taxonomies: four tasks corresponding to lifting and holding the object with different grasp configurations, and seven to manipulating the object (rotation around each of its axis and translation). The grasping and unloading forces and object rotations were measured during the five phases of the actions: unloading, lifting, holding or manipulation, preparation to deposit, and deposit. The results confirm the tight regulation between grasping and unloading forces during lifting, and extend this to the deposit phase. In addition, they provide a precise description of the regulation of force exchanges during various manipulation tasks spanning representative actions of daily life. The timing of manipulation showed both sequential and overlapping organization of the different sub-actions, and micro-errors could be detected. This phenomenological study confirms the feasibility of using an instrumented object to investigate complex manipulative behavior in humans. This protocol will be used in the future to investigate upper-limb dexterity in patients with sensory-motor impairments. PMID:28562617
Practical quantum coin flipping
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pappa, Anna; Diamanti, Eleni; Chailloux, Andre
2011-11-15
We show that in the unconditional security model, a single quantum strong coin flip with security guarantees that are strictly better than in any classical protocol is possible to implement with current technology. Our protocol takes into account all aspects of an experimental implementation, including losses, multiphoton pulses emitted by practical photon sources, channel noise, detector dark counts, and finite quantum efficiency. We calculate the abort probability when both players are honest, as well as the probability of one player forcing his desired outcome. For a channel length up to 21 km and commonly used parameter values, we can achievemore » honest abort and cheating probabilities that are better than in any classical protocol. Our protocol is, in principle, implementable using attenuated laser pulses, with no need for entangled photons or any other specific resources.« less
Two Different Fatigue Protocols and Lower Extremity Motion Patterns During a Stop-Jump Task
Quammen, David; Cortes, Nelson; Van Lunen, Bonnie L.; Lucci, Shawn; Ringleb, Stacie I.; Onate, James
2012-01-01
Context: Altered neuromuscular control strategies during fatigue probably contribute to the increased incidence of non-contact anterior cruciate ligament injuries in female athletes. Objective: To determine biomechanical differences between 2 fatigue protocols (slow linear oxidative fatigue protocol [SLO-FP] and functional agility short-term fatigue protocol [FAST-FP]) when performing a running-stop-jump task. Design: Controlled laboratory study. Setting: Laboratory. Patients or Other Participants: A convenience sample of 15 female soccer players (age = 19.2 ±0.8 years, height = 1.67±0.05m, mass = 61.7 + 8.1 kg) without injury participated. Intervention(s): Five successful trials of a running–stop-jump task were obtained prefatigue and postfatigue during the 2 protocols. For the SLO-FP, a peak oxygen consumption (V˙o2peak) test was conducted before the fatigue protocol. Five minutes after the conclusion of the V˙o2peak test, participants started the fatigue protocol by performing a 30-minute interval run. The FAST-FP consisted of 4 sets of a functional circuit. Repeated 2 (fatigue protocol) × 2 (time) analyses of variance were conducted to assess differences between the 2 protocols and time (prefatigue, postfatigue). Main Outcome Measure(s): Kinematic and kinetic measures of the hip and knee were obtained at different times while participants performed both protocols during prefatigue and postfatigue. Results: Internal adduction moment at initial contact (IC) was greater during FAST-FP (0.064 ±0.09 Nm/kgm) than SLO-FP (0.024±0.06 Nm/kgm) (F1,14 = 5.610, P=.03). At IC, participants had less hip flexion postfatigue (44.7°±8.1°) than prefatigue (50.1°±9.5°) (F1,14 = 16.229, P=.001). At peak vertical ground reaction force, participants had less hip flexion postfatigue (44.7°±8.4°) than prefatigue (50.4°±10.3°) (F1,14 = 17.026, P=.001). At peak vertical ground reaction force, participants had less knee flexion postfatigue (−35.9°±6.5°) than prefatigue (−38.8°±5.03°) (F1,14 = 11.537, P=.001). Conclusions: Our results demonstrated a more erect landing posture due to a decrease in hip and knee flexion angles in the postfatigue condition. The changes were similar between protocols; however, the FAST-FP was a clinically applicable 5-minute protocol, whereas the SLO-FP lasted approximately 45 minutes. PMID:22488228
Stephens, John R; Liles, E Allen; Dancel, Ria; Gilchrist, Michael; Kirsch, Jonathan; DeWalt, Darren A
2014-04-01
Clinicians caring for patients seeking alcohol detoxification face many challenges, including lack of evidence-based guidelines for treatment and high recidivism rates. To develop a standardized protocol for determining which alcohol dependent patients seeking detoxification need inpatient versus outpatient treatment, and to study the protocol's implementation. Review of best evidence by ad hoc task force and subsequent creation of standardized protocol. Prospective observational evaluation of initial protocol implementation. Patients presenting for alcohol detoxification. Development and implementation of a protocol for evaluation and treatment of patients requesting alcohol detoxification. Number of admissions per month with primary alcohol related diagnosis (DRG), 30-day readmission rate, and length of stay, all measured before and after protocol implementation. We identified one randomized clinical trial and three cohort studies to inform the choice of inpatient versus outpatient detoxification, along with one prior protocol in this population, and combined that data with clinical experience to create an institutional protocol. After implementation, the average number of alcohol related admissions was 15.9 per month, compared with 18.9 per month before implementation (p = 0.037). There was no difference in readmission rate or length of stay. Creation and utilization of a protocol led to standardization of care for patients requesting detoxification from alcohol. Initial evaluation of protocol implementation showed a decrease in number of admissions.
2016-08-16
Force Research Laboratory Space Vehicles Directorate AFRL /RVSV 3550 Aberdeen Ave, SE 11. SPONSOR/MONITOR’S REPORT Kirtland AFB, NM 87117-5776 NUMBER...Ft Belvoir, VA 22060-6218 1 cy AFRL /RVIL Kirtland AFB, NM 87117-5776 2 cys Official Record Copy AFRL /RVSV/Richard S. Erwin 1 cy... AFRL -RV-PS- AFRL -RV-PS- TR-2016-0112 TR-2016-0112 SPECIFICATION, SYNTHESIS, AND VERIFICATION OF SOFTWARE-BASED CONTROL PROTOCOLS FOR FAULT-TOLERANT
2006-12-14
marriage partner. On October 6, 1999, the U.N. General Assembly adopted an Optional Protocol to strengthen the Convention.7 The Protocol entered into force...Consent to Marriage (1957).8 In 1967, after two years of negotiations, the U.N. General Assembly adopted the Declaration on the Elimination of... Malaysia ; Mauritius; Netherlands; Portugal; Republic of Korea; Singapore; Slovenia; South Africa; and Thailand. 12 A full list of CEDAW Committee
Cyber Defence in the Armed Forces of the Czech Republic
2010-11-01
undesirable action backward discovery. This solution is based on special tools using NetFlow protocol. Active network elements or specialized hardware...probes attached to the backbone network using a tap can be the sources of NetFlow data. The principal advantage of NetFlow protocol is the fact that it...provides primary data in the open form, which can be easily utilized in the subsequent operations. The FlowMon Probe 4000 is mostly used NetFlow
Intermodulation Atomic Force Microscopy and Spectroscopy
NASA Astrophysics Data System (ADS)
Hutter, Carsten; Platz, Daniel; Tholen, Erik; Haviland, David; Hansson, Hans
2009-03-01
We present a powerful new method of dynamic AFM, which allows to gain far more information about the tip-surface interaction than standard amplitude or phase imaging, while scanning at comparable speed. Our method, called intermodulation atomic force microscopy (ImAFM), employs the manifestly nonlinear phenomenon of intermodulation to extract information about tip-surface forces. ImAFM uses one eigenmode of a mechanical resonator, the latter driven at two frequencies to produce many spectral peaks near its resonace, where sensitivity is highest [1]. We furthermore present a protocol for decoding the combined information encoded in the spectrum of intermodulation peaks. Our theoretical framework suggests methods to enhance the gained information by using a different parameter regime as compared to Ref. [1]. We also discuss strategies for solving the inverse problem, i.e., for extracting the nonlinear tip-surface interaction from the response, also naming limitations of our theoretical analysis. We will further report on latest progress to experimentally employ our new protocol.[3pt] [1] D. Platz, E. A. Tholen, D. Pesen, and D. B. Haviland, Appl. Phys. Lett. 92, 153106 (2008).
Bi-Force: large-scale bicluster editing and its application to gene expression data biclustering
Sun, Peng; Speicher, Nora K.; Röttger, Richard; Guo, Jiong; Baumbach, Jan
2014-01-01
Abstract The explosion of the biological data has dramatically reformed today's biological research. The need to integrate and analyze high-dimensional biological data on a large scale is driving the development of novel bioinformatics approaches. Biclustering, also known as ‘simultaneous clustering’ or ‘co-clustering’, has been successfully utilized to discover local patterns in gene expression data and similar biomedical data types. Here, we contribute a new heuristic: ‘Bi-Force’. It is based on the weighted bicluster editing model, to perform biclustering on arbitrary sets of biological entities, given any kind of pairwise similarities. We first evaluated the power of Bi-Force to solve dedicated bicluster editing problems by comparing Bi-Force with two existing algorithms in the BiCluE software package. We then followed a biclustering evaluation protocol in a recent review paper from Eren et al. (2013) (A comparative analysis of biclustering algorithms for gene expressiondata. Brief. Bioinform., 14:279–292.) and compared Bi-Force against eight existing tools: FABIA, QUBIC, Cheng and Church, Plaid, BiMax, Spectral, xMOTIFs and ISA. To this end, a suite of synthetic datasets as well as nine large gene expression datasets from Gene Expression Omnibus were analyzed. All resulting biclusters were subsequently investigated by Gene Ontology enrichment analysis to evaluate their biological relevance. The distinct theoretical foundation of Bi-Force (bicluster editing) is more powerful than strict biclustering. We thus outperformed existing tools with Bi-Force at least when following the evaluation protocols from Eren et al. Bi-Force is implemented in Java and integrated into the open source software package of BiCluE. The software as well as all used datasets are publicly available at http://biclue.mpi-inf.mpg.de. PMID:24682815
Electrical Stimulation Frequency and Skeletal Muscle Characteristics: Effects on Force and Fatigue.
Vromans, Maria; Faghri, Pouran
2017-12-05
This investigation aimed to determine the force and muscle surface electromyography (EMG) responses to different frequencies of electrical stimulation (ES) in two groups of muscles with different size and fiber composition (fast- and slow-twitch fiber proportions) during a fatigue-inducing protocol. Progression towards fatigue was evaluated in the abductor pollicis brevis (APB) and vastus lateralis (VL) when activated by ES at three frequencies (10, 35, and 50Hz). Ten healthy adults (mean age: 23.2 ± 3.0 years) were recruited; participants signed an IRB approved consent form prior to participation. Protocols were developed to 1) identify initial ES current intensity required to generate the 25% maximal voluntary contraction (MVC) at each ES frequency and 2) evaluate changes in force and EMG activity during ES-induced contraction at each frequency while progressing towards fatigue. For both muscles, stimulation at 10Hz required higher current intensity of ES to generate the initial force. There was a significant decline in force in response to ES-induced fatigue for all frequencies and for both muscles (p<0.05). However, the EMG response was not consistent between muscles. During the progression towards fatigue, the APB displayed an initial drop in force followed by an increase in EMG activity and the VL displayed a decrease in EMG activity for all frequencies. Overall, it appeared that there were some significant interactions between muscle size and fiber composition during progression towards fatigue for different ES frequencies. It could be postulated that muscle characteristics (size and fiber composition) should be considered when evaluating progression towards fatigue as EMG and force responses are not consistent between muscles.
Effect of old age on human skeletal muscle force-velocity and fatigue properties
Callahan, Damien M.
2011-01-01
It is generally accepted that the muscles of aged individuals contract with less force, have slower relaxation rates, and demonstrate a downward shift in their force-velocity relationship. The factors mediating age-related differences in skeletal muscle fatigue are less clear. The present study was designed to test the hypothesis that age-related shifts in the force-velocity relationship impact the fatigue response in a velocity-dependent manner. Three fatigue protocols, consisting of intermittent, maximum voluntary knee extension contractions performed for 4 min, were performed by 11 young (23.5 ± 0.9 yr, mean ± SE) and 10 older (68.9 ± 4.3) women. The older group fatigued less during isometric contractions than the young group (to 71.1 ± 3.7% initial torque and 59.8 ± 2.5%, respectively; P = 0.02), while the opposite was true during contractions performed at a relatively high angular velocity of 270°·s−1 (old: 28.0 ± 3.9% initial power, young: 52.1 ± 6.9%; P < 0.01). Fatigue was not different (P = 0.74) between groups during contractions at an intermediate velocity, which was selected for each participant based on their force-velocity relationship. There was a significant association between force-velocity properties and fatigue induced by the intermediate-velocity fatigue protocol in the older (r = 0.72; P = 0.02) and young (r = 0.63; P = 0.04) groups. These results indicate that contractile velocity has a profound impact on age-related skeletal muscle fatigue resistance and suggest that changes in the force-velocity relationship partially mediate this effect. PMID:21868683
Meher, Biswa Ranjan; Kumar, Mattaparthi Venkata Satish; Bandyopadhyay, Pradipta
2014-01-01
The dynamics of HIV-1 protease (HIV-pr), a drug target for HIV infection, has been studied extensively by both computational and experimental methods. The flap dynamics of HIV-pr is considered to be more important for better ligand binding and enzymatic actions. Moreover, it has been demonstrated that the drug-induced mutations can change the flap dynamics of HIV-pr affecting the binding affinity of the ligands. Therefore, detailed understanding of flap dynamics is essential for designing better inhibitors. Previous computational investigations observed significant variation in the flap opening in nanosecond time scale indicating that the dynamics is highly sensitive to the simulation protocols. To understand the sensitivity of the flap dynamics on the force field and simulation protocol, molecular dynamics simulations of HIV-pr have been performed with two different AMBER force fields, ff99 and ff02. Two different trajectories (20 ns each) were obtained using the ff99 and ff02 force field. The results showed polarizable force field (ff02) make the flap tighter than the nonpolarizable force field (ff99). Some polar interactions and hydrogen bonds involving flap residues were found to be stronger with ff02 force field. The formation of interchain hydrophobic cluster (between flap tip of one chain and active site wall of another chain) was found to be dominant in the semi-open structures obtained from the simulations irrespective of the force field. It is proposed that an inhibitor, which will promote this interchain hydrophobic clustering, may make the flaps more rigid, and presumably the effect of mutation would be small on ligand binding.
Zhang, Yuejin; Wei, Fuxiang; Poh, Yeh-Chuin; Jia, Qiong; Chen, Junjian; Chen, Junwei; Luo, Junyu; Yao, Wenting; Zhou, Wenwen; Huang, Wei; Yang, Fang; Zhang, Yao; Wang, Ning
2017-07-01
Cells and tissues can undergo a variety of biological and structural changes in response to mechanical forces. Only a few existing techniques are available for quantification of structural changes at high resolution in response to forces applied along different directions. 3D-magnetic twisting cytometry (3D-MTC) is a technique for applying local mechanical stresses to living cells. Here we describe a protocol for interfacing 3D-MTC with confocal fluorescence microscopy. In 3D-MTC, ferromagnetic beads are bound to the cell surface via surface receptors, followed by their magnetization in any desired direction. A magnetic twisting field in a different direction is then applied to generate rotational shear stresses in any desired direction. This protocol describes how to combine magnetic-field-induced mechanical stimulation with confocal fluorescence microscopy and provides an optional extension for super-resolution imaging using stimulated emission depletion (STED) nanoscopy. This technology allows for rapid real-time acquisition of a living cell's mechanical responses to forces via specific receptors and for quantifying structural and biochemical changes in the same cell using confocal fluorescence microscopy or STED. The integrated 3D-MTC-microscopy platform takes ∼20 d to construct, and the experimental procedures require ∼4 d when carried out by a life sciences graduate student.
Zhang, Yuejin; Wei, Fuxiang; Poh, Yeh-Chuin; Jia, Qiong; Chen, Junjian; Chen, Junwei; Luo, Junyu; Yao, Wenting; Zhou, Wenwen; Huang, Wei; Yang, Fang; Zhang, Yao; Wang, Ning
2017-01-01
Cells and tissues can undergo a variety of biological and structural changes in response to mechanical forces. Only few existing techniques are available for quantification of structural changes at high resolution in response to forces applied along different directions. Three dimensional-Magnetic Twisting Cytometry (3D-MTC) is a technique for applying local mechanical stresses on living cells. Here we describe a protocol for interfacing 3D-MTC with confocal fluorescence microscopy. In 3D-MTC, ferromagnetic beads are bound to the cell surface via surface receptors followed by their magnetization in any desired direction. A magnetic twisting field in a different direction is then applied to generate rotational shear stresses in any desired direction. This protocol describes how to combine magnetic field-induced mechanical stimulation with confocal fluorescence microscopy and provides an optional extension for super resolution imaging using stimulated emission depletion (STED) nanoscopy. This technology allows for rapid real time acquisition of a living cell’s mechanical responses to forces via specific receptors and for quantifying structural and biochemical changes in the same cell using confocal fluorescence microscopy or STED. The integrated 3D-MTC – microscopy platform takes around 20 days to construct and the experimental procedures require ~4 days when carried out by a life sciences graduate student. PMID:28686583
Improvement of isometric dorsiflexion protocol for assessment of tibialis anterior muscle strength☆
Siddiqi, Ariba; Arjunan, Sridhar P.; Kumar, Dinesh
2015-01-01
It is important to accurately estimate the electromyogram (EMG)/force relationship of triceps surae (TS) muscle for detecting strength deficit of tibalis anterior (TA) muscle. In literature, the protocol for recording EMG and force of dorsiflexion have been described, and the necessity for immobilizing the ankle has been explained. However, there is a significant variability of the results among researchers even though they report the fixation of the ankle. We have determined that toe extension can cause significant variation in the dorsiflexion force and EMG of TS and this can occur despite following the current guidelines which require immobilizing the ankle. The results also show that there was a large increase in the variability of the force and the RMS of EMG of TS when the toes were not strapped compared with when they were strapped. Thus, with the current guidelines, where there are no instructions regarding the necessity of strapping the toes, the EMG/force relationship of TS could be incorrect and give an inaccurate assessment of the dorsiflexor TA strength. In summary, • Current methodology to estimate the dorsiflexor TA strength with respect to the TS activity, emphasizing on ankle immobilization is insufficient to prevent large variability in the measurements. • Toe extension during dorsiflexion was found to be one source of variability in estimating the TA strength. • It is recommended that guidelines for recording force and EMG from TA and TS muscles should require the strapping of the toes along with the need for immobilizing the ankle. PMID:26150978
NASA Astrophysics Data System (ADS)
Naik, V.; Mauzerall, D. L.; Horowitz, L.; Schwarzkopf, D.; Ramaswamy, V.; Oppenheimer, M.
2004-12-01
The global distribution of tropospheric ozone (O3) depends on the location of emissions of its precursors in addition to chemical and dynamical factors. The global picture of O3 forcing is, therefore, a sum of regional forcings arising from emissions of precursors from different sources. The Kyoto Protocol does not include ozone as a greenhouse gas, and emission reductions of ozone precursors made under Kyoto or any similar agreement would presently receive no credit. In this study, we quantitatively estimate the contribution of emissions of nitrogen oxides (NOx), the primary limiting O3 precursor in the non-urban atmosphere, from specific countries and regions of the world to global O3 concentration distributions. We then estimate radiative forcing resulting from the regional perturbations of NOx emissions. This analysis is intended as an early step towards incorporating O3 into the Kyoto Protocol or any successor agreement. Under such a system countries could obtain credit for improvements in local air quality that result in reductions of O3 concentrations because of the associated reductions in radiative forcing. We use the global chemistry transport model, MOZART-2, to simulate the global O3 distribution for base year 1990 and perturbations to this distribution caused by a 10% percent reduction in the base emissions of NOx from the United States, Europe, East Asia, India, South America, and Africa. We calculate the radiative forcing for the simulated base and perturbed O3 distributions using the GFDL radiative transfer model. The difference between the radiative forcing from O3 for the base and perturbed distributions provides an estimate of the marginal radiative forcing from a region's emissions of NOx. We will present a quantitative analysis of the magnitude, spatial, and temporal distribution of radiative forcing resulting from marginal changes in the NOx emissions from each region.
2016-08-01
quasi -static mechanical properties, deformation behavior, and damage mechanisms in HSHDC and compare the behavior with VHSC. 2. Develop experimental ...using the experimental setup described in Chapter 6. The quasi -static strain rate was approximately 10-4/s. All panels tested have nominal dimensions...ER D C TR -1 6- 13 Force Protection Basing; TeCD 1a Equipment and Protocols for Quasi -Static and Dynamic Tests of Very-High-Strength
Tensile and Microindentation Stress-Strain Curves of Al-6061
Weaver, Jordan S [Los Alamos National Lab. (LANL), Los Alamos, NM (United States). Center for Integrated Nanotechnologies (CINT); Khosravani, Ali [Georgia Inst. of Technology, Atlanta, GA (United States); Castillo, Andrew [Georgia Inst. of Technology, Atlanta, GA (United States); Kalidind, Surya R [Georgia Inst. of Technology, Atlanta, GA (United States)
2016-07-13
Recent spherical microindentation stress-strain protocols were developed and validated on Al-6061 (DOI: 10.1186/s40192-016-0054-3). The scaling factor between the uniaxial yield strength and the indentation yield strength was determined to be about 1.9. The microindentation stress-strain protocols were then applied to a microstructurally graded sample in an effort to extract high throughput process-property relationships. The tensile and microindentation force-displacement and stress-strain data are presented in this data set.
Neyroud, Daria; Cheng, Arthur J; Bourdillon, Nicolas; Kayser, Bengt; Place, Nicolas; Westerblad, Håkan
2016-01-01
The interpolated twitch technique (ITT) is the gold standard to assess voluntary activation and central fatigue. Yet, its validity has been questioned. Here we studied how peripheral fatigue can affect the ITT. Repeated contractions at submaximal frequencies were produced by supramaximal electrical stimulations of the human adductor pollicis muscle in vivo and of isolated rat soleus fiber bundles; an extra stimulation pulse was given during contractions to induce a superimposed twitch. Human muscles fatigued by repeated 30-Hz stimulation trains (3 s on-1 s off) showed an ~80% reduction in the superimposed twitch force accompanied by a severely reduced EMG response (M-wave amplitude), which implies action potential failure. Subsequent experiments combined a less intense stimulation protocol (1.5 s on-3 s off) with ischemia to cause muscle fatigue, but which preserved M-wave amplitude. However, the superimposed twitch force still decreased markedly more than the potentiated twitch force; with ITT this would reflect increased "voluntary activation." In contrast, the superimposed twitch force was relatively spared when a similar protocol was performed in rat soleus bundles. Force relaxation was slowed by >150% in fatigued human muscles, whereas it was unchanged in rat soleus bundles. Accordingly, results similar to those in the human muscle were obtained when relaxation was slowed by cooling the rat soleus muscles. In conclusion, our data demonstrate that muscle fatigue can confound the quantification of central fatigue using the ITT.
Dynamics of neural cryptography
NASA Astrophysics Data System (ADS)
Ruttor, Andreas; Kinzel, Wolfgang; Kanter, Ido
2007-05-01
Synchronization of neural networks has been used for public channel protocols in cryptography. In the case of tree parity machines the dynamics of both bidirectional synchronization and unidirectional learning is driven by attractive and repulsive stochastic forces. Thus it can be described well by a random walk model for the overlap between participating neural networks. For that purpose transition probabilities and scaling laws for the step sizes are derived analytically. Both these calculations as well as numerical simulations show that bidirectional interaction leads to full synchronization on average. In contrast, successful learning is only possible by means of fluctuations. Consequently, synchronization is much faster than learning, which is essential for the security of the neural key-exchange protocol. However, this qualitative difference between bidirectional and unidirectional interaction vanishes if tree parity machines with more than three hidden units are used, so that those neural networks are not suitable for neural cryptography. In addition, the effective number of keys which can be generated by the neural key-exchange protocol is calculated using the entropy of the weight distribution. As this quantity increases exponentially with the system size, brute-force attacks on neural cryptography can easily be made unfeasible.
Dynamics of neural cryptography.
Ruttor, Andreas; Kinzel, Wolfgang; Kanter, Ido
2007-05-01
Synchronization of neural networks has been used for public channel protocols in cryptography. In the case of tree parity machines the dynamics of both bidirectional synchronization and unidirectional learning is driven by attractive and repulsive stochastic forces. Thus it can be described well by a random walk model for the overlap between participating neural networks. For that purpose transition probabilities and scaling laws for the step sizes are derived analytically. Both these calculations as well as numerical simulations show that bidirectional interaction leads to full synchronization on average. In contrast, successful learning is only possible by means of fluctuations. Consequently, synchronization is much faster than learning, which is essential for the security of the neural key-exchange protocol. However, this qualitative difference between bidirectional and unidirectional interaction vanishes if tree parity machines with more than three hidden units are used, so that those neural networks are not suitable for neural cryptography. In addition, the effective number of keys which can be generated by the neural key-exchange protocol is calculated using the entropy of the weight distribution. As this quantity increases exponentially with the system size, brute-force attacks on neural cryptography can easily be made unfeasible.
Dynamics of neural cryptography
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ruttor, Andreas; Kinzel, Wolfgang; Kanter, Ido
2007-05-15
Synchronization of neural networks has been used for public channel protocols in cryptography. In the case of tree parity machines the dynamics of both bidirectional synchronization and unidirectional learning is driven by attractive and repulsive stochastic forces. Thus it can be described well by a random walk model for the overlap between participating neural networks. For that purpose transition probabilities and scaling laws for the step sizes are derived analytically. Both these calculations as well as numerical simulations show that bidirectional interaction leads to full synchronization on average. In contrast, successful learning is only possible by means of fluctuations. Consequently,more » synchronization is much faster than learning, which is essential for the security of the neural key-exchange protocol. However, this qualitative difference between bidirectional and unidirectional interaction vanishes if tree parity machines with more than three hidden units are used, so that those neural networks are not suitable for neural cryptography. In addition, the effective number of keys which can be generated by the neural key-exchange protocol is calculated using the entropy of the weight distribution. As this quantity increases exponentially with the system size, brute-force attacks on neural cryptography can easily be made unfeasible.« less
Aircraft Simulator: Multiple-Cockpit Combat Mission Trainer Network.
1984-01-01
Force Human Resources Laboratory (AFHRL), the Air Force Office of Scientific Research (AFOSR), and the Southeastern Center for Electrical Engineering...New York: IEEE Press. Rapumno, R. A. , A Shimsaki, N. (1974). Synchronization of earth stations to satellite-switched sequences. Comunications ...Satellite Technology, 33 (Progress in Astronautics and Aeronautics) , 411-429. Tobagi, F. A. (1980). Multiaccess protocols in packet comunication systems. IEEE TMS. C". , 4 (vol. CO-28), 468-488. 27 ORR .0--000
Identifying passivated dynamic force microscopy tips on H:Si(100)
NASA Astrophysics Data System (ADS)
Sharp, Peter; Jarvis, Sam; Woolley, Richard; Sweetman, Adam; Kantorovich, Lev; Pakes, Chris; Moriarty, Philip
2012-06-01
The chemical reactivity of the tip plays a central role in image formation in dynamic force microscopy, but in very many cases the state of the probe is a key experimental unknown. We show here that an H-terminated and thus chemically unreactive tip can be readily identified via characteristic imaging and spectroscopic (F(z)) signatures, including, in particular, contrast inversion, on hydrogen-passivated Si(100). We determine the tip apex termination by comparing site-specific difference force curves with the results of density functional theory, providing a clear protocol for the identification of chemically unreactive tips on silicon surfaces.
Eggimann, Becky L.; Vostrikov, Vitaly V.; Veglia, Gianluigi; Siepmann, J. Ilja
2013-01-01
We present a fast and simple protocol to obtain moderate-resolution backbone structures of helical proteins. This approach utilizes a combination of sparse backbone NMR data (residual dipolar couplings and paramagnetic relaxation enhancements) or EPR data with a residue-based force field and Monte Carlo/simulated annealing protocol to explore the folding energy landscape of helical proteins. By using only backbone NMR data, which are relatively easy to collect and analyze, and strategically placed spin relaxation probes, we show that it is possible to obtain protein structures with correct helical topology and backbone RMS deviations well below 4 Å. This approach offers promising alternatives for the structural determination of proteins in which nuclear Overha-user effect data are difficult or impossible to assign and produces initial models that will speed up the high-resolution structure determination by NMR spectroscopy. PMID:24639619
Bi-Force: large-scale bicluster editing and its application to gene expression data biclustering.
Sun, Peng; Speicher, Nora K; Röttger, Richard; Guo, Jiong; Baumbach, Jan
2014-05-01
The explosion of the biological data has dramatically reformed today's biological research. The need to integrate and analyze high-dimensional biological data on a large scale is driving the development of novel bioinformatics approaches. Biclustering, also known as 'simultaneous clustering' or 'co-clustering', has been successfully utilized to discover local patterns in gene expression data and similar biomedical data types. Here, we contribute a new heuristic: 'Bi-Force'. It is based on the weighted bicluster editing model, to perform biclustering on arbitrary sets of biological entities, given any kind of pairwise similarities. We first evaluated the power of Bi-Force to solve dedicated bicluster editing problems by comparing Bi-Force with two existing algorithms in the BiCluE software package. We then followed a biclustering evaluation protocol in a recent review paper from Eren et al. (2013) (A comparative analysis of biclustering algorithms for gene expressiondata. Brief. Bioinform., 14:279-292.) and compared Bi-Force against eight existing tools: FABIA, QUBIC, Cheng and Church, Plaid, BiMax, Spectral, xMOTIFs and ISA. To this end, a suite of synthetic datasets as well as nine large gene expression datasets from Gene Expression Omnibus were analyzed. All resulting biclusters were subsequently investigated by Gene Ontology enrichment analysis to evaluate their biological relevance. The distinct theoretical foundation of Bi-Force (bicluster editing) is more powerful than strict biclustering. We thus outperformed existing tools with Bi-Force at least when following the evaluation protocols from Eren et al. Bi-Force is implemented in Java and integrated into the open source software package of BiCluE. The software as well as all used datasets are publicly available at http://biclue.mpi-inf.mpg.de. © The Author(s) 2014. Published by Oxford University Press on behalf of Nucleic Acids Research.
Vandenboom, Rene
2014-01-01
Ca2+ entry during the action potential stimulates muscle contraction. During repetitive low frequency stimulation, skeletal muscle undergoes staircase potentiation (SP), a progressive increase in the peak twitch force induced by each successive stimulus. Multiple mechanisms, including myosin regulatory light chain phosphorylation, likely contribute to SP, a temperature-dependent process. Here, we used the Ca2+-sensitive fluorescence indicators acetoxymethyl (AM)-furaptra and AM-fura-2 to examine the intracellular Ca2+ transient (ICT) and the baseline Ca2+ level at the onset of each ICT during SP at 30 and 37°C in mouse lumbrical muscle. The stimulation protocol, 8 Hz for 8 s, resulted in a 27 ± 3% increase in twitch force at 37°C and a 7 ± 2% decrease in twitch force at 30°C (P < 0.05). Regardless of temperature, the peak rate of force production (+df/dt) was higher in all twitches relative to the first twitch (P < 0.05). Consistent with the differential effects of stimulation on twitch force at the two temperatures, raw ICT amplitude decreased during repetitive stimulation at 30°C (P < 0.05) but not at 37°C. Cytosolic Ca2+ accumulated during SP such that baseline Ca2+ at the onset of ICTs occurring late in the train was higher (P < 0.05) than that of those occurring early in the train. ICT duration increased progressively at both temperatures. This effect was not entirely proportional to the changes in twitch duration, as twitch duration characteristically decreased before increasing late in the protocol. This is the first study identifying a changing ICT as an important, and temperature-sensitive, modulator of muscle force during repetitive stimulation. Moreover, we extend previous observations by demonstrating that contraction-induced increases in baseline Ca2+ coincide with greater +df/dt but not necessarily with higher twitch force. PMID:25422504
Recommended features of protocols for long-term ecological monitoring
Oakley, Karen L.; Boudreau, Susan L.; Humphrey, Sioux-Z
2001-01-01
In 1991, the National Park Service (NPS) selected seven parks to serve as prototypes for development of a long-term ecological monitoring program. Denali National Park and Preserve was one of the prototype parks selected. The principal focus of this national program was to detect and document resource changes and to understand the forces driving those changes. One of the major tasks of each prototype park was to develop monitoring protocols. In this paper, we discuss some lessons learned and what we believe to be the most important features of protocols.One of the many lessons we have learned is that monitoring protocols vary greatly in content and format. This variation leads to confusion about what information protocols should contain and how they should be formatted. Problems we have observed in existing protocols include (1) not providing enough detail, (2) omitting critical topics (such as data management), and (3) mixing explanation with instructions. Once written, protocols often sit on the shelf to collect dust, allowing methods changes to occur without being adequately considered, tested, or documented. Because a lengthy and costly research effort is often needed to develop protocols, a vision of what the final product should look like is helpful. Based on our involvement with the prototype monitoring program for Denali (Oakley and Boudreau 2000), we recommend key features of protocols, including a scheme for linking protocols to data in the data management system and for tracking protocol revisions. A protocol system is crucial for producing long-term data sets of known quality that meet program objectives.
The acute effects of heavy back squats on mechanical variables during a series of bilateral hops.
Moir, Gavin L; Dale, Jonathan R; Dietrich, Wendy W
2009-07-01
The purpose of the present study was to investigate the acute effects of performing a heavy resistance exercise (HRE) protocol on the mechanical variables during a series of bilateral hops. In a block-randomized design, 10 strength trained men performed an HRE or a control treatment before performing 5 series of bilateral hops separated by 2 minutes of passive recovery. Each series of bilateral hops was performed for 15 seconds on a force platform with the subject hopping at a frequency of 2.0 Hz. From the vertical force trace, the vertical force during the countermovement phase of each hop, the negative displacement during the countermovement phase, and the vertical stiffness were calculated. The HRE treatment consisted of performing parallel back squats with 40, 50, 60, and 80% of each subject's 1-repetition maximum after a series of dynamic stretches. The control treatment consisted of the dynamic stretches only. No significant differences in any of the mechanical variables were reported after the 2 treatments (p > 0.05). There were no significant correlations between the absolute maximal strength values and the percent change in any of the mechanical variables after the 2 treatments. Despite the lack of significant changes reported for the group, there were some notable individual responses. It is possible that increases in vertical stiffness during bilateral hops can be achieved after an HRE protocol in certain individuals. However, practitioners should be aware of the specificity issues and the individual nature of the responses to such protocols.
Effects of a Low-Load Gluteal Warm-Up on Explosive Jump Performance
Comyns, Thomas; Kenny, Ian; Scales, Gerard
2015-01-01
The purpose of this study was to investigate the effects of a low-load gluteal warm-up protocol on countermovement and squat jump performance. Research by Crow et al. (2012) found that a low-load gluteal warm-up could be effective in enhancing peak power output during a countermovement jump. Eleven subjects performed countermovement and squat jumps before and after the gluteal warm-up protocol. Both jumps were examined in separate testing sessions and performed 30 seconds, and 2, 4, 6 & 8 minutes post warm-up. Height jumped and peak ground reaction force were the dependent variables examined in both jumps, with 6 additional variables related to fast force production being examined in the squat jump only. All jumps were performed on a force platform (AMTI OR6-5). Repeated measures analysis of variance found a number of significant differences (p ≤ 0.05) between baseline and post warm-up scores. Height jumped decreased significantly in both jumps at all rest intervals excluding 8 minutes. Improvement was seen in 7 of the 8 recorded SJ variables at the 8 minute interval. Five of these improvements were deemed statistically significant, namely time to peak GRF (43.0%), and time to the maximum rate of force development (65.7%) significantly decreased, while starting strength (63.4%), change of force in first 100 ms of contraction (49.1%) and speed strength (43.6%) significantly increased. The results indicate that a gluteal warm-up can enhance force production in squat jumps performed after 8 minutes recovery. Future research in this area should include additional warm-up intervention groups for comparative reasons. PMID:26240661
O'Shea, Luke; Watkins, Ed; Farrand, Paul
2017-06-15
Evidence highlights a high prevalence of common mental health disorders in armed forces veterans and their families, with depression, anxiety, alcohol misuse and anger being more common than PTSD. This paper presents a protocol for a systematic review and meta-analysis to identify existing randomised controlled trial (RCT) research testing the effectiveness of psychological interventions for these difficulties in armed forces veterans and their family members. Electronic databases (CENTRAL, PsycInfo, MEDLINE, CINAHL, The Cochrane Register of Clinical Trials, EMBASE and ASSIA) will be searched to identify suitable studies for inclusion in the review supplemented by forward and backward reference checking, grey literature searches and contact with subject authors. Research including armed forces veterans and their family members will be included in the review with research including serving personnel or individuals under the age of 18 being excluded. Few RCTs examining the treatment of depression, anxiety, alcohol misuse or anger exist in armed forces veterans to date. The primary outcome will be symptomatic change following intervention for these difficulties. The secondary outcomes will include methodological aspects of interest such as discharge type and recruitment setting if data permits. In the event that the number of studies identified is too low to undertake a meta-analysis, a narrative review will be conducted. Quality assessment will be undertaken using the Cochrane Collaboration Tool and Cochran's Q statistic calculated to test for heterogeneity as suggested by the Cochrane handbook. The review will examine the findings of existing intervention research for depression, anxiety, alcohol misuse or anger in armed forces veterans and their families, along with any effect sizes that may exist. PROSPERO CRD42016036676.
Haug, M; Reischl, B; Prölß, G; Pollmann, C; Buckert, T; Keidel, C; Schürmann, S; Hock, M; Rupitsch, S; Heckel, M; Pöschel, T; Scheibel, T; Haynl, C; Kiriaev, L; Head, S I; Friedrich, O
2018-04-15
We engineered an automated biomechatronics system, MyoRobot, for robust objective and versatile assessment of muscle or polymer materials (bio-)mechanics. It covers multiple levels of muscle biosensor assessment, e.g. membrane voltage or contractile apparatus Ca 2+ ion responses (force resolution 1µN, 0-10mN for the given sensor; [Ca 2+ ] range ~ 100nM-25µM). It replaces previously tedious manual protocols to obtain exhaustive information on active/passive biomechanical properties across various morphological tissue levels. Deciphering mechanisms of muscle weakness requires sophisticated force protocols, dissecting contributions from altered Ca 2+ homeostasis, electro-chemical, chemico-mechanical biosensors or visco-elastic components. From whole organ to single fibre levels, experimental demands and hardware requirements increase, limiting biomechanics research potential, as reflected by only few commercial biomechatronics systems that can address resolution, experimental versatility and mostly, automation of force recordings. Our MyoRobot combines optical force transducer technology with high precision 3D actuation (e.g. voice coil, 1µm encoder resolution; stepper motors, 4µm feed motion), and customized control software, enabling modular experimentation packages and automated data pre-analysis. In small bundles and single muscle fibres, we demonstrate automated recordings of (i) caffeine-induced-, (ii) electrical field stimulation (EFS)-induced force, (iii) pCa-force, (iv) slack-tests and (v) passive length-tension curves. The system easily reproduces results from manual systems (two times larger stiffness in slow over fast muscle) and provides novel insights into unloaded shortening velocities (declining with increasing slack lengths). The MyoRobot enables automated complex biomechanics assessment in muscle research. Applications also extend to material sciences, exemplarily shown here for spider silk and collagen biopolymers. Copyright © 2017 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Jungclaus, Johann H.; Bard, Edouard; Baroni, Mélanie; Braconnot, Pascale; Cao, Jian; Chini, Louise P.; Egorova, Tania; Evans, Michael; Fidel González-Rouco, J.; Goosse, Hugues; Hurtt, George C.; Joos, Fortunat; Kaplan, Jed O.; Khodri, Myriam; Klein Goldewijk, Kees; Krivova, Natalie; LeGrande, Allegra N.; Lorenz, Stephan J.; Luterbacher, Jürg; Man, Wenmin; Maycock, Amanda C.; Meinshausen, Malte; Moberg, Anders; Muscheler, Raimund; Nehrbass-Ahles, Christoph; Otto-Bliesner, Bette I.; Phipps, Steven J.; Pongratz, Julia; Rozanov, Eugene; Schmidt, Gavin A.; Schmidt, Hauke; Schmutz, Werner; Schurer, Andrew; Shapiro, Alexander I.; Sigl, Michael; Smerdon, Jason E.; Solanki, Sami K.; Timmreck, Claudia; Toohey, Matthew; Usoskin, Ilya G.; Wagner, Sebastian; Wu, Chi-Ju; Leng Yeo, Kok; Zanchettin, Davide; Zhang, Qiong; Zorita, Eduardo
2017-11-01
The pre-industrial millennium is among the periods selected by the Paleoclimate Model Intercomparison Project (PMIP) for experiments contributing to the sixth phase of the Coupled Model Intercomparison Project (CMIP6) and the fourth phase of the PMIP (PMIP4). The past1000 transient simulations serve to investigate the response to (mainly) natural forcing under background conditions not too different from today, and to discriminate between forced and internally generated variability on interannual to centennial timescales. This paper describes the motivation and the experimental set-ups for the PMIP4-CMIP6 past1000 simulations, and discusses the forcing agents orbital, solar, volcanic, and land use/land cover changes, and variations in greenhouse gas concentrations. The past1000 simulations covering the pre-industrial millennium from 850 Common Era (CE) to 1849 CE have to be complemented by historical simulations (1850 to 2014 CE) following the CMIP6 protocol. The external forcings for the past1000 experiments have been adapted to provide a seamless transition across these time periods. Protocols for the past1000 simulations have been divided into three tiers. A default forcing data set has been defined for the Tier 1 (the CMIP6 past1000) experiment. However, the PMIP community has maintained the flexibility to conduct coordinated sensitivity experiments to explore uncertainty in forcing reconstructions as well as parameter uncertainty in dedicated Tier 2 simulations. Additional experiments (Tier 3) are defined to foster collaborative model experiments focusing on the early instrumental period and to extend the temporal range and the scope of the simulations. This paper outlines current and future research foci and common analyses for collaborative work between the PMIP and the observational communities (reconstructions, instrumental data).
Current Development in Reproductive Toxicity Testing of Pesticides
A protocol to evaluate the potential developmental and reproductive effects of test chemicals has been developed by the Life Stages Task Force of the International Life Sciences Institute (ILSI)/Health and Environmental Sciences Institute (HESI) Agricultural Chemical Safety Asses...
Shaping the National Guard in a Post-War Environment
2012-09-01
IRR Individual Ready Reserve xiv JCS Joint Chiefs of Staff JFHQ Joint Forces Headquarters JTF Joint Task Force LAPD Los Angeles ... changing -of- the -guard/. 35 budget is a mirror of 2010, with future budgets projected to be capped at 2009 levels . In a troubled economy, DoD is...thesis are those of the author and do not reflect the official policy or position of the Department of Defense or the U.S. Government. IRB Protocol
Sex differences in sensorimotor mu rhythms during selective attentional processing.
Popovich, C; Dockstader, C; Cheyne, D; Tannock, R
2010-12-01
We used magnetoencephalography to investigate the effect of directed attention on sensorimotor mu (8-12 Hz) response (mu reactivity) to non-painful electrical stimulation of the median nerve in healthy adults. Mu desynchronization in the 10-12 Hz bandwidth is typically observed during higher-order cognitive functions including selective attentional processing of sensorimotor information (Pfurtscheller, Neuper, & Krauz, 2000). We found attention-related sex differences in mu reactivity, with females showing (i) prolonged mu desynchrony when attending to somatosensory stimuli, (ii) attentional modulation of the mu response based on whether attention was directed towards or away from somatosensory stimuli, which was absent in males, and (iii) a trend for greater neuronal excitability of the primary somatosensory region suggesting greater physiological responsiveness to sensory stimulation overall. Our findings suggest sex differences in attentional control strategies when processing somatosensory stimuli, whose salience may be greater for females. These sex differences in attention to somatosensory stimuli may help elucidate the well-documented sex biases in pain processing wherein females typically report greater sensitivity to experimental and clinical pain. Copyright © 2010 Elsevier Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
Wyatt, J. K.; Ritz-De Cecco, A.; Czeisler, C. A.; Dijk, D. J.
1999-01-01
The interaction of homeostatic and circadian processes in the regulation of waking neurobehavioral functions and sleep was studied in six healthy young subjects. Subjects were scheduled to 15-24 repetitions of a 20-h rest/activity cycle, resulting in desynchrony between the sleep-wake cycle and the circadian rhythms of body temperature and melatonin. The circadian components of cognitive throughput, short-term memory, alertness, psychomotor vigilance, and sleep disruption were at peak levels near the temperature maximum, shortly before melatonin secretion onset. These measures exhibited their circadian nadir at or shortly after the temperature minimum, which in turn was shortly after the melatonin maximum. Neurobehavioral measures showed impairment toward the end of the 13-h 20-min scheduled wake episodes. This wake-dependent deterioration of neurobehavioral functions can be offset by the circadian drive for wakefulness, which peaks in the latter half of the habitual waking day during entrainment. The data demonstrate the exquisite sensitivity of many neurobehavioral functions to circadian phase and the accumulation of homeostatic drive for sleep.
Broxterman, Ryan M; Layec, Gwenael; Hureau, Thomas J; Amann, Markus; Richardson, Russell S
2017-05-01
Although all-out exercise protocols are commonly used, the physiological mechanisms underlying all-out exercise performance are still unclear, and an in-depth assessment of skeletal muscle bioenergetics is lacking. Therefore, phosphorus magnetic resonance spectroscopy ( 31 P-MRS) was utilized to assess skeletal muscle bioenergetics during a 5-min all-out intermittent isometric knee-extensor protocol in eight healthy men. Metabolic perturbation, adenosine triphosphate (ATP) synthesis rates, ATP cost of contraction, and mitochondrial capacity were determined from intramuscular concentrations of phosphocreatine (PCr), inorganic phosphate (P i ), diprotonated phosphate ([Formula: see text]), and pH. Peripheral fatigue was determined by exercise-induced alterations in potentiated quadriceps twitch force (Q tw ) evoked by supramaximal electrical femoral nerve stimulation. The oxidative ATP synthesis rate (ATP OX ) attained and then maintained peak values throughout the protocol, despite an ~63% decrease in quadriceps maximal force production. ThusATP OX normalized to force production (ATP OX gain) significantly increased throughout the exercise (1st min: 0.02 ± 0.01, 5th min: 0.04 ± 0.01 mM·min -1 ·N -1 ), as did the ATP cost of contraction (1st min: 0.048 ± 0.019, 5th min: 0.052 ± 0.015 mM·min -1 ·N -1 ). Additionally, the pre- to postexercise change in Q tw (-52 ± 26%) was significantly correlated with the exercise-induced change in intramuscular pH ( r = 0.75) and [Formula: see text] concentration ( r = 0.77). In conclusion, the all-out exercise protocol utilized in the present study elicited a "slow component-like" increase in intramuscular ATP OX gain as well as a progressive increase in the phosphate cost of contraction. Furthermore, the development of peripheral fatigue was closely related to the perturbation of specific fatigue-inducing intramuscular factors (i.e., pH and [Formula: see text] concentration). NEW & NOTEWORTHY The physiological mechanisms and skeletal muscle bioenergetics underlying all-out exercise performance are unclear. This study revealed an increase in oxidative ATP synthesis rate gain and the ATP cost of contraction during all-out exercise. Furthermore, peripheral fatigue was related to the perturbation in pH and deprotonated phosphate ion. These findings support the concept that the oxygen uptake slow component arises from within active skeletal muscle and that skeletal muscle force generating capacity is linked to the intramuscular metabolic milieu.
An Improved Optical Tweezers Assay for Measuring the Force Generation of Single Kinesin Molecules
Nicholas, Matthew P.; Rao, Lu; Gennerich, Arne
2014-01-01
Numerous microtubule-associated molecular motors, including several kinesins and cytoplasmic dynein, produce opposing forces that regulate spindle and chromosome positioning during mitosis. The motility and force generation of these motors are therefore critical to normal cell division, and dysfunction of these processes may contribute to human disease. Optical tweezers provide a powerful method for studying the nanometer motility and piconewton force generation of single motor proteins in vitro. Using kinesin-1 as a prototype, we present a set of step-by-step, optimized protocols for expressing a kinesin construct (K560-GFP) in Escherichia coli, purifying it, and studying its force generation in an optical tweezers microscope. We also provide detailed instructions on proper alignment and calibration of an optical trapping microscope. These methods provide a foundation for a variety of similar experiments. PMID:24633799
The Effects of Vibration and Muscle Fatigue on Trunk Sensorimotor Control in Low Back Pain Patients
Abboud, Jacques; Nougarou, François; Normand, Martin C.
2015-01-01
Introduction Changes in sensorimotor function and increased trunk muscle fatigability have been identified in patients with chronic low back pain (cLBP). This study assessed the control of trunk force production in conditions with and without local erector spinae muscle vibration and evaluated the influence of muscle fatigue on trunk sensorimotor control. Methods Twenty non-specific cLBP patients and 20 healthy participants were asked to perform submaximal isometric trunk extension torque with and without local vibration stimulation, before and after a trunk extensor muscle fatigue protocol. Constant error (CE), variable error (VE) as well as absolute error (AE) in peak torque were computed and compared across conditions. Trunk extensor muscle activation during isometric contractions and during the fatigue protocol was measured using surface electromyography (sEMG). Results Force reproduction accuracy of the trunk was significantly lower in the patient group (CE = 9.81 ± 2.23 Nm; AE = 18.16 ± 3.97 Nm) than in healthy participants (CE = 4.44 ± 1.68 Nm; AE = 12.23 ± 2.44 Nm). Local erector spinae vibration induced a significant reduction in CE (4.33 ± 2.14 Nm) and AE (13.71 ± 3.45 Nm) mean scores in the patient group. Healthy participants conversely showed a significant increase in CE (8.17 ± 2.10 Nm) and AE (16.29 ± 2.82 Nm) mean scores under vibration conditions. The fatigue protocol induced erector spinae muscle fatigue as illustrated by a significant decrease in sEMG median time-frequency slopes. Following the fatigue protocol, patients with cLBP showed significant decrease in sEMG root mean square activity at L4-5 level and responded in similar manner with and without vibration stimulation in regard to CE mean scores. Conclusions Patients with cLBP have a less accurate force reproduction sense than healthy participants. Local muscle vibration led to significant trunk neuromuscular control improvements in the cLBP patients before and after a muscle fatigue protocol. Muscle vibration stimulation during motor control exercises is likely to influence motor adaptation and could be considered in the treatment of cLBP. Further work is needed to clearly identify at what levels of the sensorimotor system these gains are achievable. PMID:26308725
The Effects of Vibration and Muscle Fatigue on Trunk Sensorimotor Control in Low Back Pain Patients.
Boucher, Jean-Alexandre; Abboud, Jacques; Nougarou, François; Normand, Martin C; Descarreaux, Martin
2015-01-01
Changes in sensorimotor function and increased trunk muscle fatigability have been identified in patients with chronic low back pain (cLBP). This study assessed the control of trunk force production in conditions with and without local erector spinae muscle vibration and evaluated the influence of muscle fatigue on trunk sensorimotor control. Twenty non-specific cLBP patients and 20 healthy participants were asked to perform submaximal isometric trunk extension torque with and without local vibration stimulation, before and after a trunk extensor muscle fatigue protocol. Constant error (CE), variable error (VE) as well as absolute error (AE) in peak torque were computed and compared across conditions. Trunk extensor muscle activation during isometric contractions and during the fatigue protocol was measured using surface electromyography (sEMG). Force reproduction accuracy of the trunk was significantly lower in the patient group (CE = 9.81 ± 2.23 Nm; AE = 18.16 ± 3.97 Nm) than in healthy participants (CE = 4.44 ± 1.68 Nm; AE = 12.23 ± 2.44 Nm). Local erector spinae vibration induced a significant reduction in CE (4.33 ± 2.14 Nm) and AE (13.71 ± 3.45 Nm) mean scores in the patient group. Healthy participants conversely showed a significant increase in CE (8.17 ± 2.10 Nm) and AE (16.29 ± 2.82 Nm) mean scores under vibration conditions. The fatigue protocol induced erector spinae muscle fatigue as illustrated by a significant decrease in sEMG median time-frequency slopes. Following the fatigue protocol, patients with cLBP showed significant decrease in sEMG root mean square activity at L4-5 level and responded in similar manner with and without vibration stimulation in regard to CE mean scores. Patients with cLBP have a less accurate force reproduction sense than healthy participants. Local muscle vibration led to significant trunk neuromuscular control improvements in the cLBP patients before and after a muscle fatigue protocol. Muscle vibration stimulation during motor control exercises is likely to influence motor adaptation and could be considered in the treatment of cLBP. Further work is needed to clearly identify at what levels of the sensorimotor system these gains are achievable.
Effectiveness of oxaliplatin desensitization protocols.
Cortijo-Cascajares, Susana; Nacle-López, Inmaculada; García-Escobar, Ignacio; Aguilella-Vizcaíno, María José; Herreros-de-Tejada, Alberto; Cortés-Funes Castro, Hernán; Calleja-Hernández, Miguel-Ángel
2013-03-01
Hypersensitivity reaction (HSR) to antineoplastic drugs can force doctors to stop treatment and seek other alternatives. These alternatives may be less effective, not as well tolerated and/or more expensive. Another option is to use desensitization protocols that induce a temporary state of tolerance by gradually administering small quantities of the antineoplastic drug until the therapeutic dosage is reached. The aim of this study is to assess the effectiveness of oxaliplatin desensitization protocols. A retrospective observational study was carried out between January 2006 and May 2011. The inclusion criteria were patients undergoing chemotherapy treatment with oxaliplatin who had developed an HSR to the drug and who were candidates for continuing the treatment using a desensitization protocol. The patients' clinical records were reviewed and variables were gathered relating to the patient, the treatment, the HSR, and the desensitization protocol administered. The data were analysed using version 18.0 of the statistics program SPSS. A total of 53 desensitization protocols were administered to 21 patients. In 89 % of these cases, no new reactions occurred while the drug was being administered. New reactions of mild severity only occurred in 11 % of cases, and none of these reactions were severe enough for treatment to be stopped. All patients were able to complete the desensitization protocol. This study confirms that oxaliplatin desensitization protocols are safe and effective and allow patients to continue with the treatment that initially caused an HSR.
Biological Rhythms During Residence in Polar Regions
2012-01-01
At Arctic and Antarctic latitudes, personnel are deprived of natural sunlight in winter and have continuous daylight in summer: light of sufficient intensity and suitable spectral composition is the main factor that maintains the 24-h period of human circadian rhythms. Thus, the status of the circadian system is of interest. Moreover, the relatively controlled artificial light conditions in winter are conducive to experimentation with different types of light treatment. The hormone melatonin and/or its metabolite 6-sulfatoxymelatonin (aMT6s) provide probably the best index of circadian (and seasonal) timing. A frequent observation has been a delay of the circadian system in winter. A skeleton photoperiod (2 × 1-h, bright white light, morning and evening) can restore summer timing. A single 1-h pulse of light in the morning may be sufficient. A few people desynchronize from the 24-h day (free-run) and show their intrinsic circadian period, usually >24 h. With regard to general health in polar regions, intermittent reports describe abnormalities in various physiological processes from the point of view of daily and seasonal rhythms, but positive health outcomes are also published. True winter depression (SAD) appears to be rare, although subsyndromal SAD is reported. Probably of most concern are the numerous reports of sleep problems. These have prompted investigations of the underlying mechanisms and treatment interventions. A delay of the circadian system with “normal” working hours implies sleep is attempted at a suboptimal phase. Decrements in sleep efficiency, latency, duration, and quality are also seen in winter. Increasing the intensity of ambient light exposure throughout the day advanced circadian phase and was associated with benefits for sleep: blue-enriched light was slightly more effective than standard white light. Effects on performance remain to be fully investigated. At 75°S, base personnel adapt the circadian system to night work within a week, in contrast to temperate zones where complete adaptation rarely occurs. A similar situation occurs on high-latitude North Sea oil installations, especially when working 18:00–06:00 h. Lack of conflicting light exposure (and “social obligations”) is the probable explanation. Many have problems returning to day work, showing circadian desynchrony. Timed light treatment again has helped to restore normal phase/sleep in a small number of people. Postprandial response to meals is compromised during periods of desynchrony with evidence of insulin resistance and elevated triglycerides, risk factors for heart disease. Only small numbers of subjects have been studied intensively in polar regions; however, these observations suggest that suboptimal light conditions are deleterious to health. They apply equally to people living in temperate zones with insufficient light exposure. PMID:22497433
Applications of Functional Analytic and Martingale Methods to Problems in Queueing Network Theory.
1983-05-14
8217’") Air Force Office of Scientific Research Sf. ADDRESS (Cllty. State and ZIP Code) 7b. ADDRESS (City. State and ZIP Code) Directorate of Mathematical... Scientific Report on Air Force Grant #82-0167 Principal Investigator: Professor Walter A. Rosenkrantz I. Publications (1) Calculation of the LaPlace transform...whether or not a protocol for accessing a comunications channel is stable. In AFOSR 82-0167, Report No. 3 we showed that the SLOTTED ALOHA Multi access
NASA Technical Reports Server (NTRS)
1994-01-01
This is a draft report on the Government Information Locator Service (GILS) to the National Information Infrastructure (NII) task force. GILS is designed to take advantage of internetworking technology known as client-server architecture which allows information to be distributed among multiple independent information servers. Two appendices are provided -- (1) A glossary of related terminology and (2) extracts from a draft GILS profile for the use of the American National Standard Information Retrieval Application Service Definition and Protocol Specification for Library Applications.
Xavier, Vivian Bertoni; Roxo, Renata Spósito; Miorin, Luiz Antônio; Dos Santos Alves, Vera Lúcia; Dos Santos Sens, Yvoty Alves
2015-06-01
Chronic kidney disease (CKD) patients on long-term dialysis present changes in pulmonary function and respiratory muscle strength, negatively influencing physical capacity. To analyze the impact of a continuous positive airway pressure (CPAP) protocol on the respiratory capacity of CKD patients under hemodialysis. A randomized clinical trial was conducted involving 40 CKD patients 19-83 years old divided into two groups: control (n = 20) and CPAP (n = 20). Subjects were assessed on the respiratory muscle function test, maximal respiratory pressures, peak flow and 6-min walk test, at baseline and again at the 2-month follow-up. CPAP group patients were submitted to CPAP protocol (PEEP: 5 cm H2O, flow: 15 L/min, FiO2: 33 %) three times per week during hemodialysis sessions. The CPAP group showed higher forced vital capacity, forced expiratory volume in one second, peak expiratory flow, maximal inspiratory pressure, peak flow, as well as lower systolic blood pressure, heart rate, respiratory rate and Borg scale, in addition to a longer distance travelled on the 6-min walk test, compared with the control group. The introduction of a CPAP protocol during hemodialysis sessions had a positive impact on pulmonary function and physical capacity in CKD patients.
Complete Prevention of Dendrite Formation in Zn Metal Anodes by Means of Pulsed Charging Protocols.
Garcia, Grecia; Ventosa, Edgar; Schuhmann, Wolfgang
2017-06-07
Zn metal as anode in rechargeable batteries, such as Zn/air or Zn/Ni, suffers from poor cyclability. The formation of Zn dendrites upon cycling is the key limiting step. We report a systematic study of the influence of pulsed electroplating protocols on the formation of Zn dendrites and in turn on strategies to completely prevent Zn dendrite formation. Because of the large number of variables in electroplating protocols, a scanning droplet cell technique was adapted as a high-throughput methodology in which a descriptor of the surface roughness can be in situ derived by means of electrochemical impedance spectroscopy. Upon optimizing the electroplating protocol by controlling nucleation, zincate ion depletion, and zincate ion diffusion, scanning electron microscopy and atomic force microscopy confirmed the growth of uniform and homogenous Zn deposits with a complete prevention of dendrite growth. The implementation of pulsed electroplating as the charging protocol for commercially available Ni-Zn batteries leads to substantially prolonged cyclability demonstrating the benefits of pulsed charging in Zn metal-based batteries.
A protocol for monitoring soft tissue motion under compression garments during drop landings.
Mills, Chris; Scurr, Joanna; Wood, Louise
2011-06-03
This study used a single-subject design to establish a valid and reliable protocol for monitoring soft tissue motion under compression garments during drop landings. One male participant performed six 40 cm drop landings onto a force platform, in three compression conditions (none, medium high). Five reflective markers placed on the thigh under the compression garment and five over the garment were filmed using two cameras (1000 Hz). Following manual digitisation, marker coordinates were reconstructed and their resultant displacements and maximum change in separation distance between skin and garment markers were calculated. To determine reliability of marker application, 35 markers were attached to the thigh over the high compression garment and filmed. Markers were then removed and re-applied on three occasions; marker separation and distance to thigh centre of gravity were calculated. Results showed similar ground reaction forces during landing trials. Significant reductions in the maximum change in separation distance between markers from no compression to high compression landings were reported. Typical errors in marker movement under and over the garment were 0.1mm in medium and high compression landings. Re-application of markers showed mean typical errors of 1mm in marker separation and <3mm relative to thigh centre of gravity. This paper presents a novel protocol that demonstrates sufficient sensitivity to detect reductions in soft tissue motion during landings in high compression garments compared to no compression. Additionally, markers placed under or over the garment demonstrate low variance in movement, and the protocol reports good reliability in marker re-application. Copyright © 2011 Elsevier Ltd. All rights reserved.
Fitzgerald, John S; Johnson, LuAnn; Tomkinson, Grant; Stein, Jesse; Roemmich, James N
2018-05-01
Mechanography during the vertical jump may enhance screening and determining mechanistic causes underlying physical performance changes. Utility of jump mechanography for evaluation is limited by scant test-retest reliability data on force-time variables. This study examined the test-retest reliability of eight jump execution variables assessed from mechanography. Thirty-two women (mean±SD: age 20.8 ± 1.3 yr) and 16 men (age 22.1 ± 1.9 yr) attended a familiarization session and two testing sessions, all one week apart. Participants performed two variations of the squat jump with squat depth self-selected and controlled using a goniometer to 80º knee flexion. Test-retest reliability was quantified as the systematic error (using effect size between jumps), random error (using coefficients of variation), and test-retest correlations (using intra-class correlation coefficients). Overall, jump execution variables demonstrated acceptable reliability, evidenced by small systematic errors (mean±95%CI: 0.2 ± 0.07), moderate random errors (mean±95%CI: 17.8 ± 3.7%), and very strong test-retest correlations (range: 0.73-0.97). Differences in random errors between controlled and self-selected protocols were negligible (mean±95%CI: 1.3 ± 2.3%). Jump execution variables demonstrated acceptable reliability, with no meaningful differences between the controlled and self-selected jump protocols. To simplify testing, a self-selected jump protocol can be used to assess force-time variables with negligible impact on measurement error.
Gianelo, M.C.S.; Polizzelo, J.C.; Chesca, D.; Mattiello-Sverzut, A.C.
2015-01-01
The aim of this study was to determine the effects of intermittent passive manual stretching on various proteins involved in force transmission in skeletal muscle. Female Wistar weanling rats were randomly assigned to 5 groups: 2 control groups containing 21- and 30-day-old rats that received neither immobilization nor stretching, and 3 test groups that received 1) passive stretching over 3 days, 2) immobilization for 7 days and then passive stretching over 3 days, or 3) immobilization for 7 days. Maximal plantar flexion in the right hind limb was imposed, and the stretching protocol of 10 repetitions of 30 s stretches was applied. The soleus muscles were harvested and processed for HE and picrosirius staining; immunohistochemical analysis of collagen types I, III, IV, desmin, and vimentin; and immunofluorescence labeling of dystrophin and CD68. The numbers of desmin- and vimentin-positive cells were significantly decreased compared with those in the control following immobilization, regardless of whether stretching was applied (P<0.05). In addition, the semi-quantitative analysis showed that collagen type I was increased and type IV was decreased in the immobilized animals, regardless of whether the stretching protocol was applied. In conclusion, the largest changes in response to stretching were observed in muscles that had been previously immobilized, and the stretching protocol applied here did not mitigate the immobilization-induced muscle changes. Muscle disuse adversely affected several proteins involved in the transmission of forces between the intracellular and extracellular compartments. Thus, the 3-day rehabilitation period tested here did not provide sufficient time for the muscles to recover from the disuse maladaptations in animals undergoing postnatal development. PMID:26648091
Gianelo, M C S; Polizzelo, J C; Chesca, D; Mattiello-Sverzut, A C
2016-02-01
The aim of this study was to determine the effects of intermittent passive manual stretching on various proteins involved in force transmission in skeletal muscle. Female Wistar weanling rats were randomly assigned to 5 groups: 2 control groups containing 21- and 30-day-old rats that received neither immobilization nor stretching, and 3 test groups that received 1) passive stretching over 3 days, 2) immobilization for 7 days and then passive stretching over 3 days, or 3) immobilization for 7 days. Maximal plantar flexion in the right hind limb was imposed, and the stretching protocol of 10 repetitions of 30 s stretches was applied. The soleus muscles were harvested and processed for HE and picrosirius staining; immunohistochemical analysis of collagen types I, III, IV, desmin, and vimentin; and immunofluorescence labeling of dystrophin and CD68. The numbers of desmin- and vimentin-positive cells were significantly decreased compared with those in the control following immobilization, regardless of whether stretching was applied (P<0.05). In addition, the semi-quantitative analysis showed that collagen type I was increased and type IV was decreased in the immobilized animals, regardless of whether the stretching protocol was applied. In conclusion, the largest changes in response to stretching were observed in muscles that had been previously immobilized, and the stretching protocol applied here did not mitigate the immobilization-induced muscle changes. Muscle disuse adversely affected several proteins involved in the transmission of forces between the intracellular and extracellular compartments. Thus, the 3-day rehabilitation period tested here did not provide sufficient time for the muscles to recover from the disuse maladaptations in animals undergoing postnatal development.
Force-controlled manipulation of single cells: from AFM to FluidFM.
Guillaume-Gentil, Orane; Potthoff, Eva; Ossola, Dario; Franz, Clemens M; Zambelli, Tomaso; Vorholt, Julia A
2014-07-01
The ability to perturb individual cells and to obtain information at the single-cell level is of central importance for addressing numerous biological questions. Atomic force microscopy (AFM) offers great potential for this prospering field. Traditionally used as an imaging tool, more recent developments have extended the variety of cell-manipulation protocols. Fluidic force microscopy (FluidFM) combines AFM with microfluidics via microchanneled cantilevers with nano-sized apertures. The crucial element of the technology is the connection of the hollow cantilevers to a pressure controller, allowing their operation in liquid as force-controlled nanopipettes under optical control. Proof-of-concept studies demonstrated a broad spectrum of single-cell applications including isolation, deposition, adhesion and injection in a range of biological systems. Copyright © 2014 Elsevier Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
Ivancic, William D.; Glover, Daniel R.; vonDeak, Thomas C.; Bhasin, Kul B.
1998-01-01
The realization of the full potential of the National Information Infrastructure (NH) and Global Information Infrastructure (GII) requires seamless interoperability of emerging satellite networks with terrestrial networks. This requires a cooperative effort between industry, academia and government agencies to develop and advocate new, satellite-friendly communication protocols and modifications to existing communication protocol standards. These groups have recently come together to actively participating in a number of standards making bodies including: the Internet Engineering Task Force (IETF), the Asynchronous Transfer Mode (ATM) Forum, the International Telecommunication Union (ITU) and the Telecommunication Industry Association MA) to ensure that issues regarding efficient use of these protocols over satellite links are not overlooked. This paper will summarize the progress made toward standards development to achieve seamless integration and accelerate the deployment of multimedia applications.
Yang, Y; Pan, L; Lightstone, F C; Merz, K M
2016-01-01
The potential of mean force simulations, widely applied in Monte Carlo or molecular dynamics simulations, are useful tools to examine the free energy variation as a function of one or more specific reaction coordinate(s) for a given system. Implementation of the potential of mean force in the simulations of biological processes, such as enzyme catalysis, can help overcome the difficulties of sampling specific regions on the energy landscape and provide useful insights to understand the catalytic mechanism. The potential of mean force simulations usually require many, possibly parallelizable, short simulations instead of a few extremely long simulations and, therefore, are fairly manageable for most research facilities. In this chapter, we provide detailed protocols for applying the potential of mean force simulations to investigate enzymatic mechanisms for several different enzyme systems. © 2016 Elsevier Inc. All rights reserved.
Heavy-tailed distribution of the SSH Brute-force attack duration in a multi-user environment
NASA Astrophysics Data System (ADS)
Lee, Jae-Kook; Kim, Sung-Jun; Park, Chan Yeol; Hong, Taeyoung; Chae, Huiseung
2016-07-01
Quite a number of cyber-attacks to be place against supercomputers that provide highperformance computing (HPC) services to public researcher. Particularly, although the secure shell protocol (SSH) brute-force attack is one of the traditional attack methods, it is still being used. Because stealth attacks that feign regular access may occur, they are even harder to detect. In this paper, we introduce methods to detect SSH brute-force attacks by analyzing the server's unsuccessful access logs and the firewall's drop events in a multi-user environment. Then, we analyze the durations of the SSH brute-force attacks that are detected by applying these methods. The results of an analysis of about 10 thousands attack source IP addresses show that the behaviors of abnormal users using SSH brute-force attacks are based on human dynamic characteristics of a typical heavy-tailed distribution.
Moir, Gavin L; Mergy, David; Witmer, Ca; Davis, Shala E
2011-06-01
The acute effects of manipulating the volume and load of back squats on subsequent countermovement vertical jump performance were investigated in the present study. Eleven National Collegiate Athletic Association division II female volleyball players performed 10 countermovement vertical jumps (CMJs) on a force platform 2 minutes after the last squat repetition of a high-load (HL) or high-volume (HV) squat protocol. Two minutes of rest was provided between each CMJ. The HL protocol culminated in the subjects having to perform 3 repetitions with a load equivalent to 90% 1 repetition maximum (1RM) back squat, whereas 12 repetitions with a load equivalent to 37% 1RM were performed in the HV protocol. During an initial familiarization session, knee angles were recorded during a series of CMJs, and these angles were used to control the depth of descent during all subsequent back squats. Jump height (JH) and vertical stiffness (VStiff) were calculated during each of the 10 CMJ, and the change in these variables after the 2 squat protocols was assessed using an analysis of variance model with repeated measures on 2 factors (Protocol [2-levels]; Time [2-levels]). There was no significant difference in JH after the HL and HV protocols (p > 0.05). A significant Protocol × Time interaction for VStiff resulted from the increase after the HL protocol being greater than that after the HV protocol (p = 0.03). The knee angles before the HL and HV protocols were significantly greater than those measured during the initial familiarization session (p = 0.001). Although neither squat protocol provided any benefit in improving JH, the heavy squat protocol produced greater increases in VStiff during the CMJ. Because of the increased VStiff caused by the HL protocol, volleyball coaches may consider using such protocols with their players to improve performance in jumps performed from a run such as the spike and on-court agility.
Optimizing results of lithotripsy using robust electromagnetic probe.
Keeley, F X; Pye, S D; Smith, G; Tolley, D A
1999-05-01
A significant impediment to the measurement of the pressures and forces created by lithotripter shockwaves has been their destructive properties, which have rendered most measuring devices impractical. We have developed and tested a robust electromagnetic probe to measure cavitational forces in vitro in the focal zones of extracorporeal lithotripters. The probe responds to the pressure gradient generated by the radial motion of cavitation bubbles. The effects of shockwaves from the Dornier MPL 9000 electrohydraulic lithotripter were measured over the lifetime of multiple electrodes. The pulse energy from the electrodes dropped off rapidly after approximately 50% of the lifetime quoted by the manufacturer. The electrodes were more efficient at higher power settings. As a result, we altered our protocol for the treatment of ureteral stones to use a higher kilovoltage and a second electrode whenever necessary. Stone-free rates after shockwave lithotripsy (SWL) in situ for stones < 11 mm have increased from 68.2% to 83.3%, and the retreatment rate has dropped from 23% to 15%. Despite significantly higher power settings (23.7 kV v 18.7 kV; P < 0.0001), the need for sedoanalgesia has remained relatively constant (26% v 31%). Measurement of cavitational forces from lithotripters using a robust electromagnetic probe is useful in planning treatment strategy. We have demonstrated a clinically measurable improvement since implementing our new treatment protocol. Because the probe responds directly to cavitational forces, it should also prove useful for the objective comparison of different SWL machines.
Mohamed, Mohamed A; Islas, Jose F; Schwartz, Robert J; Birla, Ravi K
Development of tissue-engineered hearts for treatment of myocardial infarction or biologic pacemakers has been hindered by the production of mostly arrhythmic or in-synergistic constructs. Electrical stimulation (ES) of these constructs has been shown to produce tissues with greater twitch force and better adrenergic response. To further our understanding of the mechanisms underlying the effect of ES, we fabricated a bioreactor capable of delivering continuous or intermittent waveforms of various types to multiple constructs simultaneously. In this study, we examined the effect of an intermittent biphasic square wave on our artificial heart muscle (AHM) composed of neonatal rat cardiac cells and fibrin gel. Twitch forces, spontaneous contraction rates, biopotentials, gene expression profiles, and histologic observations were examined for the ES protocol over a 12 day culture period. We demonstrate improved consistency between samples for twitch force and contraction rate, and higher normalized twitch force amplitudes for electrically stimulated AHMs. Improvements in electrophysiology within the AHM were noted by higher conduction velocities and lower latency in electrical response for electrically stimulated AHMs. Genes expressing key electrophysiologic and structural markers peaked at days 6 and 8 of culture, only a few days after the initiation of ES. These results may be used for optimization strategies to establish protocols for producing AHMs capable of replacing damaged heart tissue in either a contractile or electrophysiologic capacity. Optimized AHMs can lead to alternative treatments to heart failure and alleviate the limited donor supply crisis.
Mohamed, Mohamed A; Islas, Jose F; Schwartz, Robert J; Birla, Ravi K
2016-01-01
Development of tissue-engineered hearts for treatment of myocardial infarction or biological pacemakers has been hindered by the production of mostly arrhythmic or in-synergistic constructs. Electrical stimulation (ES) of these constructs has been shown to produce tissues with greater twitch force and better adrenergic response. In order to further our understanding of the mechanisms underlying the effect of ES, we fabricated a bioreactor capable of delivering continuous or intermittent waveforms of various types to multiple constructs simultaneously. In this study, we examined the effect of an intermittent biphasic square wave on our artificial heart muscle (AHM) composed of neonatal rat cardiac cells and fibrin gel. Twitch forces, spontaneous contraction rates, biopotentials, gene expression profiles, and histological observations were examined for the ES protocol over a 12 day culture period. We demonstrate improved consistency between samples for twitch force and contraction rate, and higher normalized twitch force amplitudes for electrically stimulated AHM. Improvements in electrophysiology within the AHM was noted by higher conduction velocities and lower latency in electrical response for electrically stimulated AHM. Genes expressing key electrophysiological and structural markers peaked at days 6 and 8 of culture, only a few days after the initiation of ES. These results may be used for optimization strategies to establish protocols for producing AHM capable of replacing damaged heart tissue in either a contractile or electrophysiological capacity. Optimized AHM can lead to alternative treatments to heart failure and alleviate the limited donor supply crisis. PMID:28459744
USDA-ARS?s Scientific Manuscript database
Mechanography during the vertical jump test allows for evaluation of force-time variables reflecting jump execution, which may enhance screening for functional deficits that reduce physical performance and determining mechanistic causes underlying performance changes. However, utility of jump mechan...
Kijlstra, Jan David; Hu, Dongjian; van der Meer, Peter; Domian, Ibrahim J
2017-11-15
Human pluripotent stem-cell derived cardiomyocytes (hPSC-CMs) hold great promise for applications in human disease modeling, drug discovery, cardiotoxicity screening, and, ultimately, regenerative medicine. The ability to study multiple parameters of hPSC-CM function, such as contractile and electrical activity, calcium cycling, and force generation, is therefore of paramount importance. hPSC-CMs cultured on stiff substrates like glass or polystyrene do not have the ability to shorten during contraction, making them less suitable for the study of hPSC-CM contractile function. Other approaches require highly specialized hardware and are difficult to reproduce. Here we describe a protocol for the preparation of hPSC-CMs on soft substrates that enable shortening, and subsequently the simultaneous quantitative analysis of their contractile and electrical activity, calcium cycling, and force generation at single-cell resolution. This protocol requires only affordable and readily available materials and works with standard imaging hardware. © 2017 by John Wiley & Sons, Inc. Copyright © 2017 John Wiley & Sons, Inc.
Grip force control in individuals with multiple sclerosis.
Iyengar, Veena; Santos, Marcio J; Ko, Michael; Aruin, Alexander S
2009-10-01
Appropriate regulation of grip force is essential in performance of various activities of daily living such as drinking, eating, buttoning a shirt, and so on. The extent to which individuals with multiple sclerosis (MS) are able to regulate grip forces while performing elements of the activities of daily living is largely unknown. . To investigate how individuals with MS control grip force during performance of functional tasks. . This study evaluated the grip force control in selected individuals with MS (n = 9) and healthy control subjects (n = 9) while they performed the task of lifting and placing an instrumented object on a shelf and the task of lifting the object and bringing it close to the mouth to mimic drinking. The grip forces, object acceleration, force ratio, and time lag were recorded and analyzed. . The individuals with MS used significantly larger peak grip force and force ratio than control subjects while performing both tasks and for both hands. In addition, the time lag between the peaks of grip and load forces was significantly longer in individuals with MS. . The application of excessive grip force could predispose individuals with MS to additional fatigue and musculoskeletal overuse trauma. Rehabilitation protocols for the MS population may need to account for increased levels of grip force applied during the performance of functional tasks.
Silva, Edward J.; Wang, Wei; Ronda, Joseph M.; Wyatt, James K.; Duffy, Jeanne F.
2010-01-01
Study Objectives: To assess circadian and homeostatic influences on subjective sleepiness and cognitive performance in older adults when sleep and waking are scheduled at different times of day; to assess changes in subjective sleepiness and cognitive performance across several weeks of an inpatient study; and to compare these findings with results from younger adults. Design: Three 24-h baseline days consisting of 16 h of wakefulness and an 8-h sleep opportunity followed by 3-beat cycles of a 20-h forced desynchrony (FD) condition; 18 20-h “days,” each consisting of 13.33 h of scheduled wakefulness and 6.67 h of scheduled sleep opportunity. Setting: Intensive Physiological Monitoring Unit of the Brigham and Women's Hospital General Clinical Research Center. Participants: 10 healthy older adults (age 64.00 ± 5.98 y, 5 females) and 10 healthy younger adults (age 24.50 ± 3.54 y, 5 females). Interventions: Wake episodes during FD scheduled to begin 4 h earlier each day allowing for data collection at a full range of circadian phases. Measurements and Results: Subjective sleepiness, cognitive throughput, and psychomotor vigilance assessed every 2 h throughout the study. Core body temperature (CBT) data collected throughout to assess circadian phase. Older subjects were less sleepy and performed significantly better on reaction time (RT) measures than younger subjects. Decrements among younger subjects increased in magnitude further into the experiment, while the performance of older subjects remained stable. Conclusions: Our findings demonstrate that the waking performance and alertness of healthy older subjects are less impacted by the cumulative effects of repeated exposure to adverse circadian phase than that of young adults. This suggests that there are age-related changes in the circadian promotion of alertness, in the wake-dependent decline of alertness, and/or in how these 2 regulatory systems interact in healthy aging. Citation: Silva EJ; Wang W; Ronda JM; Wyatt JK; Duffy JF. Circadian and wake-dependent influences on subjective sleepiness, cognitive throughput, and reaction time performance in older and young adults. SLEEP 2010;33(4):481-490. PMID:20394317
NASA Astrophysics Data System (ADS)
Pathak, Rohit; Joshi, Satyadhar
With the advent into the 20th century whole world has been facing the common dilemma of Terrorism. The suicide attacks on US twin towers 11 Sept. 2001, Train bombings in Madrid Spain 11 Mar. 2004, London bombings 7 Jul. 2005 and Mumbai attack 26 Nov. 2008 were some of the most disturbing, destructive and evil acts by terrorists in the last decade which has clearly shown their evil intent that they can go to any extent to accomplish their goals. Many terrorist organizations such as al Quaida, Harakat ul-Mujahidin, Hezbollah, Jaish-e-Mohammed, Lashkar-e-Toiba, etc. are carrying out training camps and terrorist operations which are accompanied with latest technology and high tech arsenal. To counter such terrorism our military is in need of advanced defense technology. One of the major issues of concern is secure communication. It has to be made sure that communication between different military forces is secure so that critical information is not leaked to the adversary. Military forces need secure communication to shield their confidential data from terrorist forces. Leakage of concerned data can prove hazardous, thus preservation and security is of prime importance. There may be a need to perform computations that require data from many military forces, but in some cases the associated forces would not want to reveal their data to other forces. In such situations Secure Multi-party Computations find their application. In this paper, we propose a new highly scalable Secure Multi-party Computation (SMC) protocol and algorithm for Defense applications which can be used to perform computation on encrypted data. Every party encrypts their data in accordance with a particular scheme. This encrypted data is distributed among some created virtual parties. These Virtual parties send their data to the TTP through an Anonymizer layer. TTP performs computation on encrypted data and announces the result. As the data sent was encrypted its actual value can’t be known by TTP and with the use of Anonymizers we have covered the identity of true source of data. Modifier tokens are generated along encryption of data which are distributed among virtual parties, then sent to TTP and finally used in the computation. Thus without revealing the data, right result can be computed and privacy of the parties is maintained. We have also given a probabilistic security analysis of hacking the protocol and shown how zero hacking security can be achieved.
Yoganandan, Narayan; Pintar, Frank A; Humm, John R; Maiman, Dennis J; Voo, Liming; Merkle, Andrew
2016-07-01
The purpose of this study was to determine injuries to osteo-ligamentous structures of cervical column, mechanisms, forces, severities and AIS scores from vertical accelerative loading. Seven human cadaver head-neck complexes (56.9 ± 9.5 years) were aligned based on seated the posture of military soldiers. Army combat helmets were used. Specimens were attached to a vertical accelerator to apply caudo-cephalad g-forces. They were accelerated with increasing insults. Intermittent palpation and radiography were done. A roof structure mimicking military vehicle interior was introduced after a series of tests and experiments were conducted following similar protocols. Upon injury detection, CT and dissection were done. Temporal force responses were extracted, peak forces and times of occurrence were obtained, injury severities were graded, and spine stability was determined. Injuries occurred in tests only when the roof structure was included. Responses were tri-phasic: initial thrust, secondary tensile, tertiary roof contact phases. Peak forces: 1364-4382 N, initial thrust, 165-169 N, secondary tensile, 868-3368 N tertiary helmet-head roof contact phases. Times of attainments: 5.3-9.6, 31.7-42.6, 55.0-70.8 ms. Injuries included fractures and joint disruptions. Multiple injuries occurred in all but one specimen. A majority of injury severities were AIS = 2. Spines were considered unstable in a majority of cases. Spine response was tri-phasic. Injuries occurred in roof contact tests with the helmeted head-neck specimen. Multiplicity and unstable nature of AIS = 2 level injuries, albeit at lower severities, might predispose the spine to long-term accelerated degenerative changes. Clinical protocols should include a careful evaluation of sub-catastrophic injuries in military patients.
NASA Astrophysics Data System (ADS)
Wang, Y.; Shen, C.; Liu, R.; Zhou, Z.
2014-12-01
Magnetic clouds (MCs) are the interplanetary counterparts of coronal mass ejections (CMEs). Due to the very low value of Can't connect to bucket.int.confex.com:4201 (Connection refused) LWP::Protocol::http::Socket: connect: Connection refused at /usr/local/lib/perl5/site_perl/5.8.8/LWP/Protocol/http.pm line 51. in MCs, they are believed to be in a nearly force-free state and therefore are able to be modeled by a cylindrical force-free flux rope. However, the force-free state only describes the magnetic field topology but not the plasma motion of a MC. For a MC propagating in interplanetary space, the global plasma motion has three possible components: linear propagating motion of a MC away from the Sun, expanding motion and circular motion with respect to the axis of the MC. By assuming the quasi-steady evolution and self-similar expansion, we introduced the three-component motion into the cylindrical force-free flux rope model, and developed a velocity-modified model. Then we applied the model to 73 MCs observed by Wind spacecraft to investigate the properties of the plasma motion of MCs. It is found that (1) some MCs did not propagate along the Sun-Earth line, suggesting the direct evidence of the CME's deflected propagation and/or rotation in interplanetary space, (2) the expansion speed is correlated with the radial propagation speed and 62%/17% of MCs underwent a under/over-expansion at 1 AU, and (3) the circular motion does exists though it is only on the order of 10 km s-1. These findings advance our understanding of the MC's properties at 1 AU as well as the dynamic evolution of CMEs from the Sun to interplanetary space.
The Measurement of Maximal (Anaerobic) Power Output on a Cycle Ergometer: A Critical Review
Driss, Tarak; Vandewalle, Henry
2013-01-01
The interests and limits of the different methods and protocols of maximal (anaerobic) power (P max) assessment are reviewed: single all-out tests versus force-velocity tests, isokinetic ergometers versus friction-loaded ergometers, measure of P max during the acceleration phase or at peak velocity. The effects of training, athletic practice, diet and pharmacological substances upon the production of maximal mechanical power are not discussed in this review mainly focused on the technical (ergometer, crank length, toe clips), methodological (protocols) and biological factors (muscle volume, muscle fiber type, age, gender, growth, temperature, chronobiology and fatigue) limiting P max in cycling. Although the validity of the Wingate test is questionable, a large part of the review is dedicated to this test which is currently the all-out cycling test the most often used. The biomechanical characteristics specific of maximal and high speed cycling, the bioenergetics of the all-out cycling exercises and the influence of biochemical factors (acidosis and alkalosis, phosphate ions…) are recalled at the beginning of the paper. The basic knowledge concerning the consequences of the force-velocity relationship upon power output, the biomechanics of sub-maximal cycling exercises and the study on the force-velocity relationship in cycling by Dickinson in 1928 are presented in Appendices. PMID:24073413
Reliability and Validity of the Standing Heel-Rise Test
ERIC Educational Resources Information Center
Yocum, Allison; McCoy, Sarah Westcott; Bjornson, Kristie F.; Mullens, Pamela; Burton, Gay Naganuma
2010-01-01
A standardized protocol for a pediatric heel-rise test was developed and reliability and validity are reported. Fifty-seven children developing typically (CDT) and 34 children with plantar flexion weakness performed three tests: unilateral heel rise, vertical jump, and force measurement using handheld dynamometry. Intraclass correlation…
Technical Committee on Aricultural Chemical Safety (ACSA) Life Stages Task Force
This document takes a life stages approach to the assessment of risk attributable to crop protection products, and well-known experts in the field are contributing authors. The paper presents an in-depth justification for proposed changes in current protocols for toxicity testing...
Layec, Gwenael; Hureau, Thomas J.; Amann, Markus; Richardson, Russell S.
2017-01-01
Although all-out exercise protocols are commonly used, the physiological mechanisms underlying all-out exercise performance are still unclear, and an in-depth assessment of skeletal muscle bioenergetics is lacking. Therefore, phosphorus magnetic resonance spectroscopy (31P-MRS) was utilized to assess skeletal muscle bioenergetics during a 5-min all-out intermittent isometric knee-extensor protocol in eight healthy men. Metabolic perturbation, adenosine triphosphate (ATP) synthesis rates, ATP cost of contraction, and mitochondrial capacity were determined from intramuscular concentrations of phosphocreatine (PCr), inorganic phosphate (Pi), diprotonated phosphate (H2PO4−), and pH. Peripheral fatigue was determined by exercise-induced alterations in potentiated quadriceps twitch force (Qtw) evoked by supramaximal electrical femoral nerve stimulation. The oxidative ATP synthesis rate (ATPOX) attained and then maintained peak values throughout the protocol, despite an ~63% decrease in quadriceps maximal force production. ThusATPOX normalized to force production (ATPOX gain) significantly increased throughout the exercise (1st min: 0.02 ± 0.01, 5th min: 0.04 ± 0.01 mM·min−1·N−1), as did the ATP cost of contraction (1st min: 0.048 ± 0.019, 5th min: 0.052 ± 0.015 mM·min−1·N−1). Additionally, the pre- to postexercise change in Qtw (−52 ± 26%) was significantly correlated with the exercise-induced change in intramuscular pH (r = 0.75) and H2PO4− concentration (r = 0.77). In conclusion, the all-out exercise protocol utilized in the present study elicited a “slow component-like” increase in intramuscular ATPOX gain as well as a progressive increase in the phosphate cost of contraction. Furthermore, the development of peripheral fatigue was closely related to the perturbation of specific fatigue-inducing intramuscular factors (i.e., pH and H2PO4− concentration). NEW & NOTEWORTHY The physiological mechanisms and skeletal muscle bioenergetics underlying all-out exercise performance are unclear. This study revealed an increase in oxidative ATP synthesis rate gain and the ATP cost of contraction during all-out exercise. Furthermore, peripheral fatigue was related to the perturbation in pH and deprotonated phosphate ion. These findings support the concept that the oxygen uptake slow component arises from within active skeletal muscle and that skeletal muscle force generating capacity is linked to the intramuscular metabolic milieu. PMID:28209743
Chu-Su, Yu; Shukuya, Kenichi; Yokoyama, Takashi; Lin, Wei-Chou; Chiang, Chih-Kang; Lin, Chii-Wann
2017-01-11
Urinary sediment is used to evaluate patients with possible urinary tract diseases. Currently, numerous protocols are applied to detect dysmorphic red blood cells (RBCs) and renal tubular epithelial cells (RTECs) in urinary sediment. However, distinct protocols are used by nephrologists and medical technologists for specimen concentration and observation, which leads to major discrepancies in the differential counts of formed elements such as dysmorphic RBCs and RTECs and might interfere with an accurate clinical diagnosis. To resolve these problems, we first tested a modified urinalysis protocol with an increased relative centrifuge force and concentration factor in 20 biopsy-confirmed glomerulonephritis patients with haematuria. We successfully improved the recovery ratio of dysmorphic RBCs in clinical specimens from 34.7% to 42.0% (P < 0.001). Furthermore, we confirmed the correlation between counts by the modified urinary protocol and Sysmex UF-1000i urinary flow cytometer (r ≥ 0.898, P < 0.001). A total of 28 types of isomorphic and dysmorphic RBCs were detected using a bright field microscope, with results comparable to those using a standard phase contrast microscope. Finally, we applied Sternheimer stain to enhance the contrast of RTECs in the urinary sediments. We concluded that this modified urinalysis protocol significantly enhanced the quality of urinalysis.
Chu-Su, Yu; Shukuya, Kenichi; Yokoyama, Takashi; Lin, Wei-Chou; Chiang, Chih-Kang; Lin, Chii-Wann
2017-01-01
Urinary sediment is used to evaluate patients with possible urinary tract diseases. Currently, numerous protocols are applied to detect dysmorphic red blood cells (RBCs) and renal tubular epithelial cells (RTECs) in urinary sediment. However, distinct protocols are used by nephrologists and medical technologists for specimen concentration and observation, which leads to major discrepancies in the differential counts of formed elements such as dysmorphic RBCs and RTECs and might interfere with an accurate clinical diagnosis. To resolve these problems, we first tested a modified urinalysis protocol with an increased relative centrifuge force and concentration factor in 20 biopsy-confirmed glomerulonephritis patients with haematuria. We successfully improved the recovery ratio of dysmorphic RBCs in clinical specimens from 34.7% to 42.0% (P < 0.001). Furthermore, we confirmed the correlation between counts by the modified urinary protocol and Sysmex UF-1000i urinary flow cytometer (r ≥ 0.898, P < 0.001). A total of 28 types of isomorphic and dysmorphic RBCs were detected using a bright field microscope, with results comparable to those using a standard phase contrast microscope. Finally, we applied Sternheimer stain to enhance the contrast of RTECs in the urinary sediments. We concluded that this modified urinalysis protocol significantly enhanced the quality of urinalysis. PMID:28074941
Task and fatigue effects on low-threshold motor units in human hand muscle.
Enoka, R M; Robinson, G A; Kossev, A R
1989-12-01
1. The activity of single motor units was recorded in the first dorsal interosseus muscle of human subjects while they performed an isometric ramp-and-hold maneuver. Motor-unit activity was characterized before and after fatigue by the use of a branched bipolar electrode that was positioned subcutaneously over the test muscle. Activity was characterized in terms of the forces of recruitment and derecruitment and the discharge pattern. The purpose was to determine, before and after fatigue, whether motor-unit activity was affected by the direction in which the force was exerted. 2. Regardless of the task during prefatigue trials, interimpulse intervals were 1) more variable during increases or decreases in force than when force was held constant at the target value (4-6% above the recruitment force), and 2) more clustered around an arbitrary central value than would be expected with a normal (Gaussian) distribution. Both effects were seen during the flexion and abduction tasks. The behavior of low-threshold motor units in first dorsal interosseus is thus largely unaffected by the direction of the force exerted by the index finger. The absence of a task (i.e., a direction of force) effect suggests that the resultant force vector about the metacarpophalangeal joint of the index finger is not coded in terms of discrete populations of motor units, but, rather, it is based on the net muscle activity about the joint. 3. Motor-unit behavior during and after fatigue showed that the relatively homogeneous behavior seen before fatigue could be severely disrupted. The fatiguing protocol involved the continuous repetition, to the endurance limit, of a 15-s ramp-and-hold maneuver in which the abduction target force was 50% of maximum and was held for 10-s epochs (ramps up and down were approximately 2 s each). Motor-unit threshold was assessed by the forces of recruitment and derecruitment associated with each cycle of the fatigue test. Changes in recruitment force during the protocol were either minimal or, when present, not systematic. In contrast, the derecruitment force of all units exhibited a marked and progressive increase over the course of the test. 4. After the fatigue test, when the initial threshold tasks were repeated, the behavior of most motor units changed. These changes included the derecruitment of previously active motor units, the recruitment of additional motor units, and an increased discharge variability of units that remained recruited. The variation in recruitment order seemed to be much greater than that reported previously for nonfatiguing conditions.(ABSTRACT TRUNCATED AT 400 WORDS)
Forces of Commonly Used Chiropractic Techniques for Children: A Review of the Literature.
Todd, Angela J; Carroll, Matthew T; Mitchell, Eleanor K L
2016-01-01
The purpose of this study is to review the available literature that describes forces of the most commonly used chiropractic techniques for children. Review of the English-language literature using search terms Chiropract* and technique, protocol, or approach in databases PubMed, Cumulative Index to Nursing and Allied Health Literature, Allied and Complementary Medicine, and Index to Chiropractic Literature and direct contact with authors of articles and book chapters. Eleven articles that discussed the 7 most commonly used pediatric chiropractic techniques and the forces applied were identified. Chiropractic techniques reviewed described forces that were modified based on the age of the patient. Force data for mechanically assisted devices were varied, with the minimum force settings for some devices outside the age-specific safe range recommended in the literature when not modified in some way. This review found that technique selection and application by chiropractors treating infants and young children are typically modified in force and speed to suit the age and development of the child. Copyright © 2016. Published by Elsevier Inc.
Movement of particles using sequentially activated dielectrophoretic particle trapping
Miles, Robin R.
2004-02-03
Manipulation of DNA and cells/spores using dielectrophoretic (DEP) forces to perform sample preparation protocols for polymerized chain reaction (PCR) based assays for various applications. This is accomplished by movement of particles using sequentially activated dielectrophoretic particle trapping. DEP forces induce a dipole in particles, and these particles can be trapped in non-uniform fields. The particles can be trapped in the high field strength region of one set of electrodes. By switching off this field and switching on an adjacent electrodes, particles can be moved down a channel with little or no flow.
Vulnerability Analysis of the MAVLink Protocol for Command and Control of Unmanned Aircraft
2013-03-27
the cheapest computers currently on the market (the $35 Raspberry Pi [New13, Upt13]) to distribute the workload, a determined attacker would incur a...cCost of Brute-Force) for 6,318 Raspberry Pi systems (x) at $82 per 3DR-enabled Raspberry Pi (RPCost of RasPi) [3DR13, New13] to brute-force all 3,790,800...NIST, 2004. [New13] Newark. Order the Raspberry Pi , November 2013. last accessed: 19 Febru- ary 2014. URL: http://www.newark.com/jsp/search
2017-01-01
for working in an interagency environment can lead to mission success. From the Iraq case study , one former U.S. Forces–Iraq official felt that...of six historical case studies in which the mission of special operations forces (SOF) in country transitioned over time to some level of inclusion...explanation of the methodology applied for case study selec- tion, as well as adopted interview protocols, are provided in the long- form version of
1980-11-01
hours, then overnight in a refrigerator or cold room at 40C. Fol- lowing clot retraction , the serum may be decanted and spun, or the whole sample spun...Drogram. The SIMP programme may involve one or all of the following: collection of post nasal swabs, blood sera samples, air samples and surface samples...outlined in para 16. 16. Culturing of Swabs Swabs shall be placed on Columbia Blood Agar (4 or 5% sheep RBC’s) supplemented with IsoVitalex (Baltimore
1991-12-01
UNITED STATES AIR FORCE SUMMER RESEARCH PROGRAM -- 19k’ HIGH SCF-0)OL APPRENTICESHIP PROGRAM (HSAP) REtFOC2TS VOLUME 12 ROME LABORATORY ARNOLD...capacity requirements. In the United States and Japan, it has 1.544 Mbps channels (23B+D), and Europe has 2.048 Mbps channels (30B+D). Both are provided over...because of the standard 64 kbps and the layered protocols. Even though the United States and Europe have different primary access channels, the basic
Can, Adem; Dao, David T.; Arad, Michal; Terrillion, Chantelle E.; Piantadosi, Sean C.; Gould, Todd D.
2012-01-01
The forced swim test is a rodent behavioral test used for evaluation of antidepressant drugs, antidepressant efficacy of new compounds, and experimental manipulations that are aimed at rendering or preventing depressive-like states. Mice are placed in an inescapable transparent tank that is filled with water and their escape related mobility behavior is measured. The forced swim test is straightforward to conduct reliably and it requires minimal specialized equipment. Successful implementation of the forced swim test requires adherence to certain procedural details and minimization of unwarranted stress to the mice. In the protocol description and the accompanying video, we explain how to conduct the mouse version of this test with emphasis on potential pitfalls that may be detrimental to interpretation of results and how to avoid them. Additionally, we explain how the behaviors manifested in the test are assessed. PMID:22314943
Trajectory Adjustments Underlying Task-Specific Intermittent Force Behaviors and Muscular Rhythms
Chen, Yi-Ching; Lin, Yen-Ting; Huang, Chien-Ting; Shih, Chia-Li; Yang, Zong-Ru; Hwang, Ing-Shiou
2013-01-01
Force intermittency is one of the major causes of motor variability. Focusing on the dynamics of force intermittency, this study was undertaken to investigate how force trajectory is fine-tuned for static and dynamic force-tracking of a comparable physical load. Twenty-two healthy adults performed two unilateral resistance protocols (static force-tracking at 75% maximal effort and dynamic force-tracking in the range of 50%–100% maximal effort) using the left hand. The electromyographic activity and force profile of the designated hand were monitored. Gripping force was off-line decomposed into a primary movement spectrally identical to the target motion and a force intermittency profile containing numerous force pulses. The results showed that dynamic force-tracking exhibited greater intermittency amplitude and force pulse but a smaller amplitude ratio of primary movement to force intermittency than static force-tracking. Multi-scale entropy analysis revealed that force intermittency during dynamic force-tracking was more complex on a low time scale but more regular on a high time scale than that of static force-tracking. Together with task-dependent force intermittency properties, dynamic force-tracking exhibited a smaller 8–12 Hz muscular oscillation but a more potentiated muscular oscillation at 35–50 Hz than static force-tracking. In conclusion, force intermittency reflects differing trajectory controls for static and dynamic force-tracking. The target goal of dynamic tracking is achieved through trajectory adjustments that are more intricate and more frequent than those of static tracking, pertaining to differing organizations and functioning of muscular oscillations in the alpha and gamma bands. PMID:24098640
Tolerance - One Transplant for Life
Kawai, Tatsuo; Leventhal, Joseph; Madsen, Joren C.; Strober, Samuel; Turka, Laurence A.; Wood, Kathryn J.
2014-01-01
A recent TTS workshop was convened to address the question: “What do we need to have in place to make tolerance induction protocols a “standard of care” for organ transplant recipients over the next decade?” In a productive two day meeting there was wide-ranging discussion on a broad series of topics resulting in five consensus recommendations: (1) Establish a registry of results for patients enrolled in tolerance trials; (2) Establish standardized protocols for sample collection and storage; (3) Establish standardized biomarkers and assays; (4) Include children aged 12 and older in protocols that have been validated in adults; (5) a task force to engage third party payers in discussions of how to fund tolerance trials. Future planned workshops will focus on progress in implementing these recommendations and identifying other steps that the community needs to take. PMID:24926829
Thermodynamic geometry of minimum-dissipation driven barrier crossing
NASA Astrophysics Data System (ADS)
Sivak, David A.; Crooks, Gavin E.
2016-11-01
We explore the thermodynamic geometry of a simple system that models the bistable dynamics of nucleic acid hairpins in single molecule force-extension experiments. Near equilibrium, optimal (minimum-dissipation) driving protocols are governed by a generalized linear response friction coefficient. Our analysis demonstrates that the friction coefficient of the driving protocols is sharply peaked at the interface between metastable regions, which leads to minimum-dissipation protocols that drive rapidly within a metastable basin, but then linger longest at the interface, giving thermal fluctuations maximal time to kick the system over the barrier. Intuitively, the same principle applies generically in free energy estimation (both in steered molecular dynamics simulations and in single-molecule experiments), provides a design principle for the construction of thermodynamically efficient coupling between stochastic objects, and makes a prediction regarding the construction of evolved biomolecular motors.
Thermodynamic geometry of minimum-dissipation driven barrier crossing
NASA Astrophysics Data System (ADS)
Sivak, David; Crooks, Gavin
We explore the thermodynamic geometry of a simple system that models the bistable dynamics of nucleic acid hairpins in single molecule force-extension experiments. Near equilibrium, optimal (minimum-dissipation) driving protocols are governed by a generalized linear response friction coefficient. Our analysis demonstrates that the friction coefficient of the driving protocols is sharply peaked at the interface between metastable regions, which leads to minimum-dissipation protocols that drive rapidly within a metastable basin, but then linger longest at the interface, giving thermal fluctuations maximal time to kick the system over the barrier. Intuitively, the same principle applies generically in free energy estimation (both in steered molecular dynamics simulations and in single-molecule experiments), provides a design principle for the construction of thermodynamically efficient coupling between stochastic objects, and makes a prediction regarding the construction of evolved biomolecular motors.
Casellato, Claudia; Gandolla, Marta; Crippa, Alessandro; Pedrocchi, Alessandra
2017-07-01
Autism spectrum disorder (ASD) is a multifaceted neurodevelopmental disorder characterized by a persistence of social and communication impairment, and restricted and repetitive behaviors. However, motor disorders have also been described, but not objectively assessed. Most studies showed inefficient eye-hand coordination and motor learning in children with ASD; in other experiments, mechanisms of acquisition of internal models in self-generated movements appeared to be normal in autism. In this framework, we have developed a robotic protocol, recording gaze and hand data during upper limb tasks, in which a haptic pen-like handle is moved along specific trajectories displayed on the screen. The protocol includes trials of reaching under a perturbing force field and catching moving targets, with or without visual availability of the whole path. We acquired 16 typically-developing scholar-age children and one child with ASD as a case study. Speed-accuracy tradeoff, motor performance, and gaze-hand spatial coordination have been evaluated. Compared to typically developing peers, in the force field sequence, the child with ASD showed an intact but delayed learning, and more variable gazehand patterns. In the catching trials, he showed less efficient movements, but an intact capability of exploiting the available a-priori plan. The proposed protocol represents a powerful tool, easily tunable, for quantitative (longitudinal) assessment, and for subject-tailored training in ASD.
Lucas, Morgan; Ilin, Yana; Anunu, Rachel; Kehat, Orli; Xu, Lin; Desmedt, Aline; Richter-Levin, Gal
2014-09-01
Findings suggest that stress-induced impaired learning and coping abilities may be attributed more to the psychological nature of the stressor, rather than its physical properties. It has been proposed that establishing controllability over stressors can ameliorate some of its effects on cognition and behavior. Gaining controllability was suggested to be associated with the development of stress resilience. Based on repeated exposure to the two-way shuttle avoidance task, we previously developed and validated a behavioral task that leads to a strict dissociation between gaining controllability (to the level that the associated fear is significantly reduced) and a fearful state of uncontrollability. Employing this protocol, we investigated here the impact of gaining or failing to gain emotional controllability on indices of anxiety and depression and on subsequent abilities to cope with positively or negatively reinforcing learning experiences. In agreement with previous studies, rats exposed to the uncontrollable protocol demonstrated high concentration of sera corticosterone, increased immobility, reduced duration of struggling in the forced swim test and impaired ability to acquire subsequent learning tasks. Achieving emotional controllability resulted in resilience to stress as was indicated by longer duration of struggling in the forced swim test, and enhanced learning abilities. Our prolonged training protocol, with the demonstrated ability of rats to gain emotional controllability, is proposed as a useful tool to study the neurobiological mechanisms of stress resilience.
[Climatic change and public health: scenarios after the coming into force of the Kyoto Protocol].
Ballester, Ferran; Díaz, Julio; Moreno, José Manuel
2006-03-01
According to the reports of the intergovernmental panel for climatic change (IPCC) human beings of the present and near future are going to experiment, in fact we are already experimenting, important changes in the world climate. Conscious of the magnitude of the problem, international organizations have taken a series of initiatives headed to stop the climatic change and to reduce its impact. This willingness has been shaped into the agreements established in the Kyoto protocol, where countries commit to reduce greenhouse-effect gas emissions. Kyoto protocol has come into force on February 16th 2005 with the support of 141 signing countries. Among the major worries are the effects which climatic change may have upon health, such as: 1) changes in the morbidity- mortality related to temperature; 2) Effects on health related with extreme meteorological events (tornados, storms, hurricanes and extreme raining); 3) Air pollution and increase of associated health effects; d) Diseases transmitted by food and water and 4) Infectious diseases transmitted by vectors and by rodents. Even if all the countries in the world committed to the Kyoto Protocol, some consequences of the climatic change will be inevitable; among them some will have a negative impact on health. It would be necessary to adapt a key response strategy to minimize the impacts of climatic change and to reduce, at minimum cost, its adverse effects on health. From the Public Health position, a relevant role can and must be played concerning the understanding of the risks for health of such climatic changes, the design of surveillance systems to evaluate possible impacts, and the establishment of systems to prevent or reduce damages as well as the identification and development of investigation needs.
Tactile Sensing Reflexes for Advanced Prosthetic Hands
2016-10-01
mos.) 100% • Design and build “mechanical egg ” test equipment (1-2 mos.) (Abandoned, alternate approach developed) • Develop experimental protocol...of a “mechanical egg ” or force measuring object was rejected in favor of this common cracker. Page 6 • A comprehensive bench top study was
ERIC Educational Resources Information Center
Highland, Zachary L.; Saner, ChaMarra K.; Garno, Jayne C.
2018-01-01
Experiments are described that involve undergraduates learning concepts of nanoscience and chemistry. Students prepare nanopatterns of organosilane films using protocols of particle lithography. A few basic techniques are needed to prepare samples, such as centrifuging, mixing, heating, and drying. Students obtain hands-on skills with nanoscale…
USDA-ARS?s Scientific Manuscript database
Mechanography during the vertical jump may enhance screening and determining mechanistic causes for functional deficits that reduce physical performance. Utility of jump mechanography for evaluation is limited by scant test-retest reliability data on force-time variables. This study examined the tes...
A protocol for conducting rainfall simulation to study soil runoff
USDA-ARS?s Scientific Manuscript database
Rainfall is a driving force for the transport of environmental contaminants from agricultural soils to surficial water bodies via surface runoff. The objective of this study was to characterize the effects of antecedent soil moisture content on the fate and transport of surface applied commercial ur...
The Submersible Threat to Maritime Homeland Security
2013-09-01
government . IRB Protocol number ____N/A____. 12a. DISTRIBUTION / AVAILABILITY STATEMENT Approved for public release; distribution is unlimited 12b...20 Figure 8. Privately Owned Tourist Submersible (From Atlantis Submarine off Maui...Armed Forces of Colombia (Spanish) FLIR Forward Looking Infrared Radar GAO Government Accountability Office GPS Global Positioning System
2010-11-01
hours. Training must incorporate language, culture, norms, customs, etiquette , religion, etc as to how not offend the local ethnicities.” SOF Leader...consensus. The frequency of occurrence for each theme is presented in this report. Analysis of the focus group data followed the same protocol , except
Fair loss-tolerant quantum coin flipping
DOE Office of Scientific and Technical Information (OSTI.GOV)
Berlin, Guido; Brassard, Gilles; Bussieres, Felix
Coin flipping is a cryptographic primitive in which two spatially separated players, who do not trust each other, wish to establish a common random bit. If we limit ourselves to classical communication, this task requires either assumptions on the computational power of the players or it requires them to send messages to each other with sufficient simultaneity to force their complete independence. Without such assumptions, all classical protocols are so that one dishonest player has complete control over the outcome. If we use quantum communication, on the other hand, protocols have been introduced that limit the maximal bias that dishonestmore » players can produce. However, those protocols would be very difficult to implement in practice because they are susceptible to realistic losses on the quantum channel between the players or in their quantum memory and measurement apparatus. In this paper, we introduce a quantum protocol and we prove that it is completely impervious to loss. The protocol is fair in the sense that either player has the same probability of success in cheating attempts at biasing the outcome of the coin flip. We also give explicit and optimal cheating strategies for both players.« less
The relationship of motor unit size, firing rate and force.
Conwit, R A; Stashuk, D; Tracy, B; McHugh, M; Brown, W F; Metter, E J
1999-07-01
Using a clinical electromyographic (EMG) protocol, motor units were sampled from the quadriceps femoris during isometric contractions at fixed force levels to examine how average motor unit size and firing rate relate to force generation. Mean firing rates (mFRs) and sizes (mean surface-detected motor unit action potential (mS-MUAP) area) of samples of active motor units were assessed at various force levels in 79 subjects. MS-MUAP size increased linearly with increased force generation, while mFR remained relatively constant up to 30% of a maximal force and increased appreciably only at higher force levels. A relationship was found between muscle force and mS-MUAP area (r2 = 0.67), mFR (r2 = 0.38), and the product of mS-MUAP area and mFR (mS-MUAP x mFR) (r2 = 0.70). The results support the hypothesis that motor units are recruited in an orderly manner during forceful contractions, and that in large muscles only at higher levels of contraction ( > 30% MVC) do mFRs increase appreciably. MS-MUAP and mFR can be assessed using clinical EMG techniques and they may provide a physiological basis for analyzing the role of motor units during muscle force generation.
Loading forces in shallow water running in two levels of immersion.
Haupenthal, Alessandro; Ruschel, Caroline; Hubert, Marcel; de Brito Fontana, Heiliane; Roesler, Helio
2010-07-01
To analyse the vertical and anteroposterior components of the ground reaction force during shallow water running at 2 levels of immersion. Twenty-two healthy adults with no gait disorders, who were familiar with aquatic exercises. Subjects performed 6 trials of water running at a self-selected speed in chest and hip immersion. Force data were collected through an underwater force plate and running speed was measured with a photocell timing light system. Analysis of covariance was used for data analysis. Vertical forces corresponded to 0.80 and 0.98 times the subject's body weight at the chest and hip level, respectively. Anteroposterior forces corresponded to 0.26 and 0.31 times the subject's body weight at the chest and hip level, respectively. As the water level decreased the subjects ran faster. No significant differences were found for the force values between the immersions, probably due to variability in speed, which was self-selected. When thinking about load values in water running professionals should consider not only the immersion level, but also the speed, as it can affect the force components, mainly the anteroposterior one. Quantitative data on this subject could help professionals to conduct safer aqua-tic rehabilitation and physical conditioning protocols.
Melatonin and Pancreatic Islets: Interrelationships between Melatonin, Insulin and Glucagon
Peschke, Elmar; Bähr, Ina; Mühlbauer, Eckhard
2013-01-01
The pineal hormone melatonin exerts its influence in the periphery through activation of two specific trans-membrane receptors: MT1 and MT2. Both isoforms are expressed in the islet of Langerhans and are involved in the modulation of insulin secretion from β-cells and in glucagon secretion from α-cells. De-synchrony of receptor signaling may lead to the development of type 2 diabetes. This notion has recently been supported by genome-wide association studies identifying particularly the MT2 as a risk factor for this rapidly spreading metabolic disturbance. Since melatonin is secreted in a clearly diurnal fashion, it is safe to assume that it also has a diurnal impact on the blood-glucose-regulating function of the islet. This factor has hitherto been underestimated; the disruption of diurnal signaling within the islet may be one of the most important mechanisms leading to metabolic disturbances. The study of melatonin–insulin interactions in diabetic rat models has revealed an inverse relationship: an increase in melatonin levels leads to a down-regulation of insulin secretion and vice versa. Elucidation of the possible inverse interrelationship in man may open new avenues in the therapy of diabetes. PMID:23535335
The impact of constant light on the estrous cycle of the rat.
Campbell, C S; Schwartz, N B
1980-04-01
The initial effects of constant bright light on the events of the rat estrous cycle were monitored in order to examine the interdependence of the hormonal and behavioral rhythms which comprise the cycle. Females exposed to constant bright light for only one cycle either failed to ovulate or showed a delay in the hormonal and behavioral events of the cycle as well as in ovulation. Females exposed to constant light for two cycles 1) failed to ovulate, 2) showed an advancement, or 3) showed a delay in the hormonal events of the estrous cycle and ovulation. Vaginal cytology and the onset of locomotor activity did not maintain their normal temporal relationships with the other events of the estrous cycle in constant light. In spite of the absence of an external timing signal, the majority of hormonal rhythms maintained their normal phase relationships and showed little sign of internal desynchrony. Ovaries in many animals showed high rates of follicular atresia early in the cycle, suggesting that the effects of bright constant light are far more complex than can be attributed to a simple absence of an external timing signal.
Preparation of isolated biomolecules for SFM observations: T4 bacteriophage as a test sample.
Droz, E; Taborelli, M; Wells, T N; Descouts, P
1993-01-01
The T4 bacteriophage has been used to investigate protocols for the preparation of samples for scanning force microscopy in air, in order to obtaining reproducible images. The resolution of images and the distribution of bacteriophages on the substrate depends on the buffer type, its concentration, the surface treatment of substrate, and the method of deposition. The best imaging conditions for the phages require dilution in a volatile buffer at low ionic strength and adsorption onto hydrophilic surfaces. When imaging with the scanning force microscopy the quality of the images is influenced by the vertical and lateral forces applied on the sample and by the tip geometry. Images FIGURE 1 FIGURE 2 FIGURE 4 FIGURE 5 FIGURE 6 PMID:8241398
Pate, Kathryn M; Sherk, Vanessa D; Carpenter, R Dana; Weaver, Michael; Crapo, Silvia; Gally, Fabienne; Chatham, Lillian S; Goldstrohm, David A; Crapo, James D; Kohrt, Wendy M; Bowler, Russell P; Oberley-Deegan, Rebecca E; Regan, Elizabeth A
2015-03-15
Osteoarthritis (OA) is associated with increased mechanical damage to joint cartilage. We have previously found that extracellular superoxide dismutase (ECSOD) is decreased in OA joint fluid and cartilage, suggesting oxidant damage may play a role in OA. We explored the effect of forced running as a surrogate for mechanical damage in a transgenic mouse with reduced ECSOD tissue binding. Transgenic mice heterozygous (Het) for the human ECSOD R213G polymorphism and 129-SvEv (wild-type, WT) mice were exposed to forced running on a treadmill for 45 min/day, 5 days/wk, over 8 wk. At the end of the running protocol, knee joint tissue was obtained for histology, immunohistochemistry, and protein analysis. Sedentary Het and WT mice were maintained for comparison. Whole tibias were studied for bone morphometry, finite element analysis, and mechanical testing. Forced running improved joint histology in WT mice. However, when ECSOD levels were reduced, this beneficial effect with running was lost. Het ECSOD runner mice had significantly worse histology scores compared with WT runner mice. Runner mice for both strains had increased bone strength in response to the running protocol, while Het mice showed evidence of a less robust bone structure in both runners and untrained mice. Reduced levels of ECSOD in cartilage produced joint damage when joints were stressed by forced running. The bone tissues responded to increased loading with hypertrophy, regardless of mouse strain. We conclude that ECSOD plays an important role in protecting cartilage from damage caused by mechanical loading. Copyright © 2015 the American Physiological Society.
Mechanical Stimulation of Stem Cells Using Cyclic Uniaxial Strain
Kurpinski, Kyle; Li, Song
2007-01-01
The role of mechanical forces in the development and maintenance of biological tissues is well documented, including several mechanically regulated phenomena such as bone remodeling, muscular hypertrophy, and smooth muscle cell plasticity. However, the forces involved are often extremely complex and difficult to monitor and control in vivo. To better investigate the effects of mechanical forces on cells, we have developed an in vitro method for applying uniaxial cyclic tensile strain to adherent cells cultured on elastic membranes. This method utilizes a custom-designed bioreactor with a motorized cam-rotor system to apply the desired force. Here we present a step-by-step video protocol demonstrating how to assemble the various components of each "stretch chamber", including, in this case, a silicone membrane with micropatterned topography to orient the cells with the direction of the strain. We also describe procedures for sterilizing the chambers, seeding cells onto the membrane, latching the chamber into the bioreactor, and adjusting the mechanical parameters (i.e. magnitude and rate of strain). The procedures outlined in this particular protocol are specific for seeding human mesenchymal stem cells onto silicone membranes with 10 µm wide channels oriented parallel to the direction of strain. However, the methods and materials presented in this system are flexible enough to accommodate a number of variations on this theme: strain rate, magnitude, duration, cell type, membrane topography, membrane coating, etc. can all be tailored to the desired application or outcome. This is a robust method for investigating the effects of uniaxial tensile strain applied to cells in vitro. PMID:18997890
Generation and Long-term Maintenance of Nerve-free Hydra.
Tran, Cassidy M; Fu, Sharon; Rowe, Trevor; Collins, Eva-Maria S
2017-07-07
The interstitial cell lineage of Hydra includes multipotent stem cells, and their derivatives: gland cells, nematocytes, germ cells, and nerve cells. The interstitial cells can be eliminated through two consecutive treatments with colchicine, a plant-derived toxin that kills dividing cells, thus erasing the potential for renewal of the differentiated cells that are derived from the interstitial stem cells. This allows for the generation of Hydra that lack nerve cells. A nerve-free polyp cannot open its mouth to feed, egest, or regulate osmotic pressure. Such animals, however, can survive and be cultured indefinitely in the laboratory if regularly force-fed and burped. The lack of nerve cells allows for studies of the role of the nervous system in regulating animal behavior and regeneration. Previously published protocols for nerve-free Hydra maintenance involve outdated techniques such as mouth-pipetting with hand-pulled micropipette tips to feed and clean the Hydra. Here, an improved protocol for maintenance of nerve-free Hydra is introduced. Fine-tipped forceps are used to force open the mouth and insert freshly killed Artemia. Following force-feeding, the body cavity of the animal is flushed with fresh medium using a syringe and hypodermic needle to remove undigested material, referred to here as "burping". This new method of force-feeding and burping nerve-free Hydra through the use of forceps and syringes eliminates the need for mouth-pipetting using hand-pulled micropipette tips. It thus makes the process safer and significantly more time efficient. To ensure that the nerve cells in the hypostome have been eliminated, immunohistochemistry using anti-tyrosine-tubulin is conducted.
Effect of hydrotherapy on the signs and symptoms of delayed onset muscle soreness.
Vaile, Joanna; Halson, Shona; Gill, Nicholas; Dawson, Brian
2008-03-01
This study independently examined the effects of three hydrotherapy interventions on the physiological and functional symptoms of delayed onset muscle soreness (DOMS). Strength trained males (n = 38) completed two experimental trials separated by 8 months in a randomised crossover design; one trial involved passive recovery (PAS, control), the other a specific hydrotherapy protocol for 72 h post-exercise; either: (1) cold water immersion (CWI: n = 12), (2) hot water immersion (HWI: n = 11) or (3) contrast water therapy (CWT: n = 15). For each trial, subjects performed a DOMS-inducing leg press protocol followed by PAS or one of the hydrotherapy interventions for 14 min. Weighted squat jump, isometric squat, perceived pain, thigh girths and blood variables were measured prior to, immediately after, and at 24, 48 and 72 h post-exercise. Squat jump performance and isometric force recovery were significantly enhanced (P < 0.05) at 24, 48 and 72 h post-exercise following CWT and at 48 and 72 h post-exercise following CWI when compared to PAS. Isometric force recovery was also greater (P < 0.05) at 24, 48, and 72 h post-exercise following HWI when compared to PAS. Perceived pain improved (P < 0.01) following CWT at 24, 48 and 72 h post-exercise. Overall, CWI and CWT were found to be effective in reducing the physiological and functional deficits associated with DOMS, including improved recovery of isometric force and dynamic power and a reduction in localised oedema. While HWI was effective in the recovery of isometric force, it was ineffective for recovery of all other markers compared to PAS.
Squat exercise biomechanics during short-radius centrifugation.
Duda, Kevin R; Jarchow, Thomas; Young, Laurence R
2012-02-01
Centrifuge-induced artificial gravity (AG) with exercise is a promising comprehensive countermeasure against the physiological de-conditioning that results from exposure to weightlessness. However, body movements onboard a rotating centrifuge are affected by both the gravity gradient and Coriolis accelerations. The effect of centrifugation on squat exercise biomechanics was investigated, and differences between AG and upright squat biomechanics were quantified. There were 28 subjects (16 male) who participated in two separate experiments. Knee position, foot reaction forces, and motion sickness were recorded during the squats in a 1-G field while standing upright and while supine on a horizontally rotating 2 m radius centrifuge at 0, 23, or 30 rpm. No participants terminated the experiment due to motion sickness symptoms. Total mediolateral knee deflection increased by 1.0 to 2.0 cm during centrifugation, and did not result in any injuries. There was no evidence of an increased mediolateral knee travel "after-effect" during postrotation supine squats. Peak foot reaction forces increased with rotation rate up to approximately 200% bodyweight (iRED on ISS provides approximately 210% bodyweight resistance). The ratio of left-to-right foot force throughout the squat cycle on the centrifuge was nonconstant and approximately sinusoidal. Total foot reaction force versus knee flexion-extension angles differed between upright and AG squats due to centripetal acceleration on the centrifuge. A brief exercise protocol during centrifugation can be safely completed without significant after-effects in mediolateral knee position or motion sickness. Several recommendations are made for the design of future centrifuge-based exercise protocols for in-space applications.
Energetics and kinetics of primary charge separation in bacterial photosynthesis.
LeBard, David N; Kapko, Vitaliy; Matyushov, Dmitry V
2008-08-21
We report the results of molecular dynamics (MD) simulations and formal modeling of the free-energy surfaces and reaction rates of primary charge separation in the reaction center of Rhodobacter sphaeroides. Two simulation protocols were used to produce MD trajectories. Standard force-field potentials were employed in the first protocol. In the second protocol, the special pair was made polarizable to reproduce a high polarizability of its photoexcited state observed by Stark spectroscopy. The charge distribution between covalent and charge-transfer states of the special pair was dynamically adjusted during the simulation run. We found from both protocols that the breadth of electrostatic fluctuations of the protein/water environment far exceeds previous estimates, resulting in about 1.6 eV reorganization energy of electron transfer in the first protocol and 2.5 eV in the second protocol. Most of these electrostatic fluctuations become dynamically frozen on the time scale of primary charge separation, resulting in much smaller solvation contributions to the activation barrier. While water dominates solvation thermodynamics on long observation times, protein emerges as the major thermal bath coupled to electron transfer on the picosecond time of the reaction. Marcus parabolas were obtained for the free-energy surfaces of electron transfer by using the first protocol, while a highly asymmetric surface was obtained in the second protocol. A nonergodic formulation of the diffusion-reaction electron-transfer kinetics has allowed us to reproduce the experimental results for both the temperature dependence of the rate and the nonexponential decay of the population of the photoexcited special pair.
Kubo, Keitaro; Kanehisa, Hiroaki; Fukunaga, Tetsuo
2001-01-01
The present study aimed to investigate the influence of isometric training protocols with long- and short-duration contractions on the elasticity of human tendon structures in vivo. The elasticity was assessed through in vivo determination of the elongation (L) of the tendons and aponeuroses using ultrasonography, while the subjects performed ramp isometric exercise up to maximum voluntary contraction (MVC).Eight young males completed 12 weeks (4 days per week) of a unilateral isometric training programme on knee extensors, which consisted of two different combinations of contraction and relaxation times at 70 % MVC: one leg was trained using a short-duration protocol (3 sets of 50 repetitions of contraction for 1 s and relaxation for 2 s), and the other leg was trained using a long-duration protocol (4 sets of a combination of contraction for 20 s and relaxation for 1 min). The training volume per session, expressed as the integrated torque, was the same for the two protocols.Both protocols resulted in a significant increase in MVC: 31.8 ± 17.2 % for the short-duration protocol and 33.9 ± 14.4 % for the long-duration protocol. Moreover, the training produced significant increases in the muscle volume of the constituents of the quadriceps femoris, with similar relative gains for the two protocols: 7.4 ± 3.9 % for the short-duration protocol and 7.6 ± 4.3 % for the long-duration protocol.The short-duration protocol produced no significant change in L values at any of the force production levels. For the long-duration protocol, however, the L values above 550 N were significantly shorter after training. Analysis revealed that the group × test time interaction effect on tendon stiffness was significant. Stiffness increased significantly for the long-duration protocol, but not for the short-duration protocol.The present study demonstrates a greater increase in stiffness of human tendon structures following isometric training using longer duration contractions compared to shorter contractions. This suggests that the changes in the elasticity of the tendon structures after resistance training may be affected by the duration of muscle contraction. PMID:11600697
MVAPACK: A Complete Data Handling Package for NMR Metabolomics
2015-01-01
Data handling in the field of NMR metabolomics has historically been reliant on either in-house mathematical routines or long chains of expensive commercial software. Thus, while the relatively simple biochemical protocols of metabolomics maintain a low barrier to entry, new practitioners of metabolomics experiments are forced to either purchase expensive software packages or craft their own data handling solutions from scratch. This inevitably complicates the standardization and communication of data handling protocols in the field. We report a newly developed open-source platform for complete NMR metabolomics data handling, MVAPACK, and describe its application on an example metabolic fingerprinting data set. PMID:24576144
Li, Li; Liu, Hong-Ju; Yang, Ming-Hao; Li, Jing-Long; Wang, Lu; Chen, Xiao-Ping; Fan, Ming
2012-03-01
To explore the relationship between contractile characteristics and fiber type conversion in hind-limb unloading mice soleus. After 28-day hind-limb unloading and muscle atrophy, we used the method of isolated muscle perfusion with different stimulated protocols to determine the changes in contractile characteristics including the isometric twitch force and tetanus force and fatigue index of slow twitch muscle in mice. The muscle myofibrillar composition and fiber type conversion were detected by immunofluorescence staining and real-time PCR. The isometric twitch force and the tetanus force and fatigue index were decreased progressively in 28-day unloaded mice soleus, with the increase in fast twitch fiber subtype and the decrease in slow twitch fiber subtype. The alteration of contractile characteristics is relevant to the slow-to-fast fiber conversion in mice soleus after 28-day hind-limb unloading.
Das, Priyadip; Duanias-Assaf, Tal; Reches, Meital
2017-03-06
The interactions between proteins or peptides and inorganic materials lead to several interesting processes. For example, combining proteins with minerals leads to the formation of composite materials with unique properties. In addition, the undesirable process of biofouling is initiated by the adsorption of biomolecules, mainly proteins, on surfaces. This organic layer is an adhesion layer for bacteria and allows them to interact with the surface. Understanding the fundamental forces that govern the interactions at the organic-inorganic interface is therefore important for many areas of research and could lead to the design of new materials for optical, mechanical and biomedical applications. This paper demonstrates a single-molecule force spectroscopy technique that utilizes an AFM to measure the adhesion force between either peptides or amino acids and well-defined inorganic surfaces. This technique involves a protocol for attaching the biomolecule to the AFM tip through a covalent flexible linker and single-molecule force spectroscopy measurements by atomic force microscope. In addition, an analysis of these measurements is included.
The influence of an uncertain force environment on reshaping trial-to-trial motor variability.
Izawa, Jun; Yoshioka, Toshinori; Osu, Rieko
2014-09-10
Motor memory is updated to generate ideal movements in a novel environment. When the environment changes every trial randomly, how does the brain incorporate this uncertainty into motor memory? To investigate how the brain adapts to an uncertain environment, we considered a reach adaptation protocol where individuals practiced moving in a force field where a noise was injected. After they had adapted, we measured the trial-to-trial variability in the temporal profiles of the produced hand force. We found that the motor variability was significantly magnified by the adaptation to the random force field. Temporal profiles of the motor variance were significantly dissociable between two different types of random force fields experienced. A model-based analysis suggests that the variability is generated by noise in the gains of the internal model. It further suggests that the trial-to-trial motor variability magnified by the adaptation in a random force field is generated by the uncertainty of the internal model formed in the brain as a result of the adaptation.
Silva, Douglas R G; Torres Filho, Robledo A; Cazedey, Henrique P; Fontes, Paulo R; Ramos, Alcinéia L S; Ramos, Eduardo M
2015-05-01
This study was conducted to investigate the effect of core sampling on Warner-Bratzler shear force evaluations of beef and pork loins (Longissimus thoracis et lumborum muscles) and to determine the relationship between them. Steaks of 2.54 cm from beef and pork loins were cooked and five round cross-section cores and five square cross-section cores of each steak were taken for shear force evaluation. Core sampling influenced both beef and pork shear force values with higher (P<0.05) average values and standard deviations for square cross-section cores. There was a strong and linear relationship (P<0.01) between round and square cross-section cores for beef (R(2)=0.78), pork (R(2)=0.70) and for beef+pork (R(2)=0.82) samples. These results indicate that it is feasible to use square cross-section cores in Warner-Bratzler shear force protocol as an alternative and potential method to standardize sampling for shear force measurements. Copyright © 2014 Elsevier Ltd. All rights reserved.
Pizzamiglio, Sara; Desowska, Adela; Shojaii, Pegah; Taga, Myriam; Turner, Duncan L
2017-01-01
Muscle co-contraction is a strategy of increasing movement accuracy and stability employed in dealing with force perturbation of movement. It is often seen in neuropathological populations. The direction of movement influences the pattern of co-contraction, but not all movements are easily achievable for populations with motor deficits. Manipulating the direction of the force instead, may be a promising rehabilitation protocol to train movement with use of a co-contraction reduction strategy. Force field learning paradigms provide a well described procedure to evoke and test muscle co-contraction. The aim of this study was to test the muscle co-contraction pattern in a wide range of arm muscles in different force-field directions utilising a robot-mediated force field learning paradigm of motor adaptation. Forty-two participants volunteered to participate in a study utilising robot-mediated force field motor adaptation paradigm with a clockwise or counter-clockwise force field. Kinematics and surface electromyography (EMG) of eight arm muscles were measured. Both muscle activation and co-contraction was earlier and stronger in flexors in the clockwise condition and in extensors in the counter-clockwise condition. Manipulating the force field direction leads to changes in the pattern of muscle co-contraction.
Pranata, Adrian; Perraton, Luke; El-Ansary, Doa; Clark, Ross; Fortin, Karine; Dettmann, Tim; Brandham, Robert; Bryant, Adam
2017-07-01
The ability to control lumbar extensor force output is necessary for daily activities. However, it is unknown whether this ability is impaired in chronic low back pain patients. Similarly, it is unknown whether lumbar extensor force control is related to the disability levels of chronic low back pain patients. Thirty-three chronic low back pain and 20 healthy people performed lumbar extension force-matching task where they increased and decreased their force output to match a variable target force within 20%-50% maximal voluntary isometric contraction. Force control was quantified as the root-mean-square-error between participants' force output and target force across the entire, during the increasing and decreasing portions of the force curve. Within- and between-group differences in force-matching error and the relationship between back pain group's force-matching results and their Oswestry Disability Index scores were assessed using ANCOVA and linear regression respectively. Back pain group demonstrated more overall force-matching error (mean difference=1.60 [0.78, 2.43], P<0.01) and more force-matching error while increasing force output (mean difference=2.19 [1.01, 3.37], P<0.01) than control group. The back pain group demonstrated more force-matching error while increasing than decreasing force output (mean difference=1.74, P<0.001, 95%CI [0.87, 2.61]). A unit increase in force-matching error while decreasing force output is associated with a 47% increase in Oswestry score in back pain group (R 2 =0.19, P=0.006). Lumbar extensor muscle force control is compromised in chronic low back pain patients. Force-matching error predicts disability, confirming the validity of our force control protocol for chronic low back pain patients. Copyright © 2017 Elsevier Ltd. All rights reserved.
Waterhouse, Jim; Jones, Kay; Edwards, Ben; Harrison, Yvonne; Nevill, Alan; Reilly, Thomas
2004-05-01
In an attempt to investigate the relative importance of endogenous and exogenous factors in determining food intake, 14 healthy subjects were studied while living in an Isolation Unit (where external time cues were absent) for eighteen 28 h "days" (equal to 21 solar days). The subjects were free to spend their waking time as they chose, and they had a free choice of what they ate and when they ate it. The only restrictions were that no naps were allowed in the "daytime," that some time was required to perform a variety of tests at regular intervals throughout the 18.67 h waking periods, and that any food preparation had to be performed by the subjects themselves. Core (rectal) temperature and activity were monitored throughout, and the subjects answered a questionnaire on their eating habits at 3 h intervals during the waking periods. The questionnaire investigated reasons for eating or not eating a meal during the previous 3 h and, if a meal had been eaten, its type, the factors influencing that choice, and the subjects' subjective responses (hunger before, enjoyment during, and satiety after) to it. The results were analyzed (two-way ANOVA) in terms of both the imposed day length (the exogenous component) and the free-running period of the temperature rhythm (the endogenous component). Results indicated that by far the main reason for eating/not eating was hunger/lack of hunger rather than factors such as food availability and time-pressure. There were statistically significant effects of time within the imposed waking periods upon the type of meal eaten--"breakfast" tending to be a snack, "lunch" a small hot meal, and the "evening meal" a large hot meal. Hot meals (whether small or large) were associated with more hunger before the meal, more enjoyment of the meal, and a greater degree of satiety afterward than were cold meals. These effects suggest that the individuals adjusted their eating habits to fit in with the imposed wake times. By contrast, the effect of circadian phase upon food intake, the type of meal eaten, and subjective responses to the meal was much weaker, and either statistically nonsignificant (P > 0.10) or only marginally so (0.10 > P > 0.05). For example, a large hot meal was chosen as readily for an "evening meal," and subjective responses to it were the same, at whatever circadian phase it was eaten. We conclude that food intake during forced desynchronization is dominated by the waking schedule rather than by circadian influences; some of the implications of these findings when eating habits and the metabolism of food are concerned, particularly in night workers, are considered briefly.
Miller, Joseph
2013-01-01
Background and Purpose: The etiology of Chronic Exertional Compartment Syndrome (CECS) is still unclear. The most commonly accepted theory suggests that it is a transient but debilitating process where there is an abnormally increased intracompartmental pressure during exercise/exertion due to non‐compliant expansion of the osteofascial tissues. This most commonly occurs in the lower leg. Surgical intervention is often performed for symptom relief. However, there has been limited scientifically‐based publication on post‐surgical rehabilitation, especially with regard to return to function in the military population. The purpose of this case report is to demonstrate the utilization of a recommended post‐operative protocol in a Special Forces Soldier. Case Description: The subject presented as a 25‐year‐old US Army Special Forces Soldier, who failed 8 weeks of conservative management for the diagnosis of CECS and subsequently underwent bilateral lower leg fasciotomies of the anterior and lateral compartments. Outcomes: Following recommended protocol guidelines he was progressed rapidly and within three months deployed without restriction or complications in a demanding combat zone. Discussion: This case report illustrates that following clearly defined, scientifically‐based rehabilitation guidelines helped in addressing all of the involved structures and musculoskeletal dysfunctions that presented following the surgical intervention for CECS in a unique subject. Level of Evidence: 5 PMID:24175149
Walsh, Mark; Peper, Andreas; Bierbaum, Stefanie; Karamanidis, Kiros; Arampatzis, Adamantios
2011-04-01
The present study aimed to investigate the effect of lower extremity muscle fatigue on the dynamic stability control of physically active adults during forward falls. Thirteen participants (body mass: 70.2kg, height: 175cm) were instructed to regain balance with a single step after a sudden induced fall from a forward-leaning position before and after the fatigue protocol. The ground reaction forces were collected using four force plates at a sampling rate of 1080Hz. Kinematic data were recorded with 12 vicon cameras operating at 120Hz. Neither the reaction time nor the duration until touchdown showed any differences (p>0.05). The ability of the subjects to prevent falling did not change after the fatigue protocol. In the fatigued condition, the participants demonstrated an increase in knee flexion during the main stance phase and an increased time to decelerate the horizontal CM motion (both p<0.05). Significant (p<0.05) decreases were seen post-fatigue in average horizontal and vertical force and maximum knee and ankle joint moments. The fatigue related decrease in muscle strength did not affect the margin of stability, the boundary of the base of support or the position of the extrapolated centre of mass during the forward induced falls, indicating an appropriate adjustment of the motor commands to compensate the deficit in muscle strength. Copyright © 2010 Elsevier Ltd. All rights reserved.
USDA-ARS?s Scientific Manuscript database
The Convention on Biological Diversity (CBD) acknowledges the sovereign rights that countries have over their ‘genetic resources’. The Nagoya Protocol that came into force in 2014 provides a framework for implementation of and equitable process by which access to, and sharing of benefits between don...
Teaching Accountability: Using Client Feedback to Train Effective Family Therapists
ERIC Educational Resources Information Center
Sparks, Jacqueline A.; Kisler, Tiffani S.; Adams, Jerome F.; Blumen, Dale G.
2011-01-01
The AAMFT Task Force on Core Competencies (Nelson et al., 2007) proposed that marriage and family therapy (MFT) educators teach and provide evidence of trainee competence beyond coursework and accrued clinical hours. This article describes the integration of a systematic client feedback protocol into an MFT-accredited program's curricula to…
U.S. Army Research Institute Program in Basic Research-FY 2010
2010-11-01
2007). Do learning protocols support learning strategies and outcomes? The role of cognitive and metacognitive prompts. Learning and Instruction ...73 Achievement in Complex Learning Environments as a Function of Information Processing Ability ...Development and Validation of a Situational Judgment Test to Predict Attrition Incrementally Over General Cognitive Ability and a Forced-Choice
Evidence-Based Psychosocial Treatments for Child and Adolescent Depression
ERIC Educational Resources Information Center
David-Ferdon, Corinne; Kaslow, Nadine J.
2008-01-01
The evidence-base of psychosocial treatment outcome studies for depressed youth conducted since 1998 is examined. All studies for depressed children meet Nathan and Gorman's (2002) criteria for Type 2 studies whereas the adolescent protocols meet criteria for both Type 1 and Type 2 studies. Based on the Task Force on the Promotion and…
An Open Source Low-Cost Wireless Control System for a Forced Circulation Solar Plant
Salamone, Francesco; Belussi, Lorenzo; Danza, Ludovico; Ghellere, Matteo; Meroni, Italo
2015-01-01
The article describes the design phase, development and practical application of a low-cost control system for a forced circulation solar plant in an outdoor test cell located near Milan. Such a system provides for the use of an electric pump for the circulation of heat transfer fluid connecting the solar thermal panel to the storage tank. The running plant temperatures are the fundamental parameter to evaluate the system performance such as proper operation, and the control and management system has to consider these parameters. A solar energy-powered wireless-based smart object was developed, able to monitor the running temperatures of a solar thermal system and aimed at moving beyond standard monitoring approaches to achieve a low-cost and customizable device, even in terms of installation in different environmental conditions. To this end, two types of communications were used: the first is a low-cost communication based on the ZigBee protocol used for control purposes, so that it can be customized according to specific needs, while the second is based on a Bluetooth protocol used for data display. PMID:26556356
An Open Source Low-Cost Wireless Control System for a Forced Circulation Solar Plant.
Salamone, Francesco; Belussi, Lorenzo; Danza, Ludovico; Ghellere, Matteo; Meroni, Italo
2015-11-05
The article describes the design phase, development and practical application of a low-cost control system for a forced circulation solar plant in an outdoor test cell located near Milan. Such a system provides for the use of an electric pump for the circulation of heat transfer fluid connecting the solar thermal panel to the storage tank. The running plant temperatures are the fundamental parameter to evaluate the system performance such as proper operation, and the control and management system has to consider these parameters. A solar energy-powered wireless-based smart object was developed, able to monitor the running temperatures of a solar thermal system and aimed at moving beyond standard monitoring approaches to achieve a low-cost and customizable device, even in terms of installation in different environmental conditions. To this end, two types of communications were used: the first is a low-cost communication based on the ZigBee protocol used for control purposes, so that it can be customized according to specific needs, while the second is based on a Bluetooth protocol used for data display.
Yun, Kang-Seop; Pai, Sung Jin; Yeo, Byung Chul; Lee, Kwang-Ryeol; Kim, Sun-Jae; Han, Sang Soo
2017-07-06
We propose the ReaxFF reactive force field as a simulation protocol for predicting the evolution of solid-electrolyte interphase (SEI) components such as gases (C 2 H 4 , CO, CO 2 , CH 4 , and C 2 H 6 ), and inorganic (Li 2 CO 3 , Li 2 O, and LiF) and organic (ROLi and ROCO 2 Li: R = -CH 3 or -C 2 H 5 ) products that are generated by the chemical reactions between the anodes and liquid electrolytes. ReaxFF was developed from ab initio results, and a molecular dynamics simulation with ReaxFF realized the prediction of SEI formation under real experimental conditions and with a reasonable computational cost. We report the effects on SEI formation of different kinds of Si anodes (pristine Si and SiO x ), of the different types and compositions of various carbonate electrolytes, and of the additives. From the results, we expect that ReaxFF will be very useful for the development of novel electrolytes or additives and for further advances in Li-ion battery technology.
Sriram, Vinay K; Montgomery, Doug
2017-07-01
The Internet is subject to attacks due to vulnerabilities in its routing protocols. One proposed approach to attain greater security is to cryptographically protect network reachability announcements exchanged between Border Gateway Protocol (BGP) routers. This study proposes and evaluates the performance and efficiency of various optimization algorithms for validation of digitally signed BGP updates. In particular, this investigation focuses on the BGPSEC (BGP with SECurity extensions) protocol, currently under consideration for standardization in the Internet Engineering Task Force. We analyze three basic BGPSEC update processing algorithms: Unoptimized, Cache Common Segments (CCS) optimization, and Best Path Only (BPO) optimization. We further propose and study cache management schemes to be used in conjunction with the CCS and BPO algorithms. The performance metrics used in the analyses are: (1) routing table convergence time after BGPSEC peering reset or router reboot events and (2) peak-second signature verification workload. Both analytical modeling and detailed trace-driven simulation were performed. Results show that the BPO algorithm is 330% to 628% faster than the unoptimized algorithm for routing table convergence in a typical Internet core-facing provider edge router.
A Cost Analysis of a Pancreatic Cancer Screening Protocol in High-Risk Populations
Bruenderman, Elizabeth; Martin, Robert CG
2016-01-01
Background Pancreatic cancer is the 4th leading cause of cancer death in the U.S. A screening protocol is needed to catch early stage, resectable disease. This study suggests a protocol for high-risk individuals and assesses the cost in the context of the Affordable Care Act. Methods Medicare and national average pricing were used for cost analysis of a protocol using MRI/MRCP biannually in high-risk groups. Results: ‘ Costs per year of life added’ based on Medicare and national average costs, respectively, are: $638.62 and $2542.37 for Peutz-Jehgers Syndrome, $945.33 and $3763.44 for Hereditary Pancreatitis, $1141.77 and $4545.45 for Familial Pancreatic Cancer and p16-Leiden mutations, and $356.42 and $1418.92 for new-onset diabetes over age 50 with weight loss or smoking. Conclusion A screening program using MRI/MRCP is affordable in high-risk populations. The U.S. Preventive Services Task Force must reevaluate its pancreatic cancer screening guidelines to make screening more cost-effective for the individual. PMID:26003200
TVD, Linnehan collects data during LMS-1 Spacelab mission
1996-07-09
STS078-430-009 (20 June-7 July 1996) --- Astronaut Richard M. Linnehan, mission specialist, performs a test on his leg using the Torque Velocity Dynamometer (TVD). Dr. Thirsk was measuring changes in muscle forces of the leg in this particular view. The TVD hardware is also used to measure arm muscle forces and velocity at the bicep and tricep areas. Crewmembers for the mission performed all experiment protocols prior to flight to develop a baseline and will also perform post-flight tests to complete the analysis. Additionally, muscle biopsies were taken before the flight and will be conducted after the flight.
Effective Swimmer’s Action during the Grab Start Technique
Mourão, Luis; de Jesus, Karla; Roesler, Hélio; Machado, Leandro J.; Fernandes, Ricardo J.; Vilas-Boas, João Paulo; Vaz, Mário A. P.
2015-01-01
The external forces applied in swimming starts have been often studied, but using direct analysis and simple interpretation data processes. This study aimed to develop a tool for vertical and horizontal force assessment based on the swimmers’ propulsive and structural forces (passive forces due to dead weight) applied during the block phase. Four methodological pathways were followed: the experimented fall of a rigid body, the swimmers’ inertia effect, the development of a mathematical model to describe the outcome of the rigid body fall and its generalization to include the effects of the inertia, and the experimental swimmers’ starting protocol analysed with the inclusion of the developed mathematical tool. The first three methodological steps resulted in the description and computation of the passive force components. At the fourth step, six well-trained swimmers performed three 15 m maximal grab start trials and three-dimensional (3D) kinetic data were obtained using a six degrees of freedom force plate. The passive force contribution to the start performance obtained from the model was subtracted from the experimental force due to the swimmers resulting in the swimmers’ active forces. As expected, the swimmers’ vertical and horizontal active forces accounted for the maximum variability contribution of the experimental forces. It was found that the active force profile for the vertical and horizontal components resembled one another. These findings should be considered in clarifying the active swimmers’ force variability and the respective geometrical profile as indicators to redefine steering strategies. PMID:25978370
By counteracting gravity, triceps surae sets both kinematics and kinetics of gait
Honeine, Jean‐Louis; Schieppati, Marco; Gagey, Oliver; Do, Manh‐Cuong
2014-01-01
Abstract In the single‐stance phase of gait, gravity acting on the center of mass (CoM) causes a disequilibrium torque, which generates propulsive force. Triceps surae activity resists gravity by restraining forward tibial rotation thereby tuning CoM momentum. We hypothesized that time and amplitude modulation of triceps surae activity determines the kinematics (step length and cadence) and kinetics of gait. Nineteen young subjects participated in two experiments. In the gait initiation (GI) protocol, subjects deliberately initiated walking at different velocities for the same step length. In the balance‐recovery (BR) protocol, subjects executed steps of different length after being unexpectedly released from an inclined posture. Ground reaction force was recorded by a large force platform and electromyography of soleus, gastrocnemius medialis and lateralis, and tibialis anterior muscles was collected by wireless surface electrodes. In both protocols, the duration of triceps activity was highly correlated with single‐stance duration (GI, R2 = 0.68; BR, R2 = 0.91). In turn, step length was highly correlated with single‐stance duration (BR, R2 = 0.70). Control of CoM momentum was obtained by decelerating the CoM fall via modulation of amplitude of triceps activity. By modulation of triceps activity, the central nervous system (CNS) varied the position of CoM with respect to the center of pressure (CoP). The CoM‐CoP gap in the sagittal plane was determinant for setting the disequilibrium torque and thus walking velocity. Thus, by controlling the gap, CNS‐modified walking velocity (GI, R2 = 0.86; BR, R2 = 0.92). This study is the first to highlight that by merely counteracting gravity, triceps activity sets the kinematics and kinetics of gait. It also provides evidence that the surge in triceps activity during fast walking is due to the increased requirement of braking the fall of CoM in late stance in order to perform a smoother step‐to‐step transition. PMID:24744898
Moon, Won; Wu, Kimberley W; MacGinnis, Matthew; Sung, Jay; Chu, Howard; Youssef, George; Machado, Andre
2015-01-01
Maxillary protraction with the novel N2 mini-implant- and micro-implant-assisted rapid palatal expander (MARPE) can potentially provide significant skeletal effects without surgery, even in older patients where conventional facemask therapy has limited skeletal effects. However, the skeletal effects of altering the location and direction of force from mini-implant-assisted maxillary protraction have not been extensively analyzed. In this study, the application of the novel N2 mini-implant as an orthopedic anchorage device is explored in its ability to treat patients with class III malocclusions. A 3D cranial mesh model with associated sutures was developed from CT images and Mimics modeling software. Utilizing ANSYS simulation software, protraction forces were applied at different locations and directions to simulate conventional facemask therapy and seven maxillary protraction protocols utilizing the novel N2 mini-implant. Stress distribution and displacement were analyzed. Video animations and superimpositions were created. By changing the vector of force and location of N2 mini-implant, the maxilla was displaced differentially. Varying degrees of forward, downward, and rotational movements were observed in each case. For brachyfacial patients, anterior micro-implant-supported protraction at -45° or intermaxillary class III elastics at -45° are recommended. For dolicofacial patients, either anterior micro-implants at -15° or an intermaxillary spring at +30° is recommended. For mesofacial patients with favorable vertical maxillary position, palatal micro-implants at -30° are recommended; anterior micro-implants at -30° are preferred for shallow bites. For patients with a severe mid-facial deficiency, intermaxillary class III elastics at -30° are most effective in promoting anterior growth of the maxilla. By varying the location of N2 mini-implants and vector of class III mechanics, clinicians can differentially alter the magnitude of forward, downward, and rotational movement of the maxilla. As a result, treatment protocol can be customized for each unique class III patient.
Pressure-flow specificity of inspiratory muscle training.
Tzelepis, G E; Vega, D L; Cohen, M E; Fulambarker, A M; Patel, K K; McCool, F D
1994-08-01
The inspiratory muscles (IM) can be trained by having a subject breathe through inspiratory resistive loads or by use of unloaded hyperpnea. These disparate training protocols are characterized by high inspiratory pressure (force) or high inspiratory flow (velocity), respectively. We tested the hypothesis that the posttraining improvements in IM pressure or flow performance are specific to training protocols in a way that is similar to force-velocity specificity of skeletal muscle training. IM training was accomplished in 15 normal subjects by use of three protocols: high inspiratory pressure-no flow (group A, n = 5), low inspiratory pressure-high flow (group B, n = 5), and intermediate inspiratory pressure and flow (group C, n = 5). A control group (n = 4) did no training. Before and after training, we measured esophageal pressure (Pes) and inspiratory flow (VI) during single maximal inspiratory efforts against a range of external resistances including an occluded airway. Efforts originated below relaxation volume (Vrel), and peak Pes and VI were measured at Vrel. Isovolume maximal Pes-VI plots were constructed to assess maximal inspiratory pressure-flow performance. Group A (pressure training) performed 30 maximal static inspiratory maneuvers at Vrel daily, group B (flow training) performed 30 sets of three maximal inspiratory maneuvers with no added external resistance daily, and group C (intermediate training) performed 30 maximal inspiratory efforts on a midrange external resistance (7 mm ID) daily. Subjects trained 5 days/wk for 6 wk. Data analysis included comparison of posttraining Pes-VI slopes among training groups.(ABSTRACT TRUNCATED AT 250 WORDS)
NASA Technical Reports Server (NTRS)
Lewis, Pattie
2005-01-01
Headquarters National Aeronautics and Space Administration (NASA) chartered the Acquisition Pollution Prevention (AP2) Office to coordinate agency activities affecting pollution prevention issues identified during system and component acquisition and sustainment processes. The primary objectives of the AP2 Office are to: (1) Reduce or eliminate the use of hazardous materials (HazMats) or hazardous processes at manufacturing, remanufacturing, and sustainment locations. (2) A void duplication of effort in actions required to reduce or eliminate HazMats through joint center cooperation and technology sharing. This project will identify, evaluate and approve alternative surface preparation technologies for use at NASA and Air Force Space Command (AFSPC) installations. Materials and processes will be evaluated with the goal of selecting those processes that will improve corrosion protection at critical systems, facilitate easier maintenance activity, extend maintenance cycles, eliminate flight hardware contamination and reduce the amount of hazardous waste generated. This Joint Test Protocol (JTP) contains the critical requirements and tests necessary to qualify alternative Low-Emission Surface Preparation/Depainting Technologies for Structural Steel Applications. These tests were derived from engineering, performance, and operational impact (supportability) requirements defined by a consensus of NASA and Air Force Space Command (AFSPC) participants. The Field Test Plan (FTP), entitled Joint Test Protocol for Validation of Alternative Low Emission Surface Preparation/Depainting Technologies for Structural Steel, prepared by ITB, defines the field evaluation and testing requirements for validating alternative surface preparation/depainting technologies and supplements the JTP.
Neuromuscular rate of force development deficit in Parkinson disease.
Hammond, Kelley G; Pfeiffer, Ronald F; LeDoux, Mark S; Schilling, Brian K
2017-06-01
Bradykinesia and reduced neuromuscular force exist in Parkinson disease. The interpolated twitch technique has been used to evaluate central versus peripheral manifestations of neuromuscular strength in healthy, aging, and athletic populations, as well as moderate to advanced Parkinson disease, but this method has not been used in mild Parkinson disease. This study aimed to evaluate quadriceps femoris rate of force development and quantify potential central and peripheral activation deficits in individuals with Parkinson disease. Nine persons with mild Parkinson Disease (Hoehn & Yahr≤2, Unified Parkinson Disease Rating Scale total score=mean 19.1 (SD 5.0)) and eight age-matched controls were recruited in a cross-sectional investigation. Quadriceps femoris voluntary and stimulated maximal force and rate of force development were evaluated using the interpolated twitch technique. Thirteen participants satisfactorily completed the protocol. Individuals with early Parkinson disease (n=7) had significantly slower voluntary rate of force development (p=0.008; d=1.97) and rate of force development ratio (p=0.004; d=2.18) than controls (n=6). No significant differences were found between groups for all other variables. Persons with mild-to-moderate Parkinson disease display disparities in rate of force development, even without deficits in maximal force. The inability to produce force at a rate comparable to controls is likely a downstream effect of central dysfunction of the motor pathway in Parkinson disease. Copyright © 2017. Published by Elsevier Ltd.
Porcelain surface conditioning protocols and shear bond strength of orthodontic brackets.
Lestrade, Ashley M; Ballard, Richard W; Xu, Xiaoming; Yu, Qingzhao; Kee, Edwin L; Armbruster, Paul C
2016-05-01
The objective of the present study was to determine which of six bonding protocols yielded a clinically acceptable shear bond strength (SBS) of metal orthodontic brackets to CAD/CAM lithium disilicate porcelain restorations. A secondary aim was to determine which bonding protocol produced the least surface damage at debond. Sixty lithium disilicate samples were fabricated to replicate the facial surface of a mandibular first molar using a CEREC CAD/CAM machine. The samples were split into six test groups, each of which received different mechanical/chemical pretreatment protocols to roughen the porcelain surface prior to bonding a molar orthodontic attachment. Shear bond strength testing was conducted using an Instron machine. The mean, maximum, minimal, and standard deviation SBS values for each sample group including an enamel control were calculated. A t-test was used to evaluate the statistical significance between the groups. No significant differences were found in SBS values, with the exception of surface roughening with a green stone prior to HFA and silane treatment. This protocol yielded slightly higher bond strength which was statistically significant. Chemical treatment alone with HFA/silane yielded SBS values within an acceptable clinical range to withstand forces applied by orthodontic treatment and potentially eliminates the need to mechanically roughen the ceramic surface.
Pugnaloni, Luis A; Carlevaro, C Manuel; Kramár, M; Mischaikow, K; Kondic, L
2016-06-01
The force network of a granular assembly, defined by the contact network and the corresponding contact forces, carries valuable information about the state of the packing. Simple analysis of these networks based on the distribution of force strengths is rather insensitive to the changes in preparation protocols or to the types of particles. In this and the companion paper [Kondic et al., Phys. Rev. E 93, 062903 (2016)10.1103/PhysRevE.93.062903], we consider two-dimensional simulations of tapped systems built from frictional disks and pentagons, and study the structure of the force networks of granular packings by considering network's topology as force thresholds are varied. We show that the number of clusters and loops observed in the force networks as a function of the force threshold are markedly different for disks and pentagons if the tangential contact forces are considered, whereas they are surprisingly similar for the network defined by the normal forces. In particular, the results indicate that, overall, the force network is more heterogeneous for disks than for pentagons. Such differences in network properties are expected to lead to different macroscale response of the considered systems, despite the fact that averaged measures (such as force probability density function) do not show any obvious differences. Additionally, we show that the states obtained by tapping with different intensities that display similar packing fraction are difficult to distinguish based on simple topological invariants.
The Acute Effects of Back Squats on Vertical Jump Performance in Men and Women
Witmer, Chad A.; Davis, Shala E.; Moir, Gavin L.
2010-01-01
The aim of the present study was to investigate the acute effects of performing back squats on subsequent performance during a series of vertical jumps in men and women. Twelve men and 12 women were tested on three separate occasions, the first of which was used to determine their 1-repetition maximum (1-RM) parallel back squat. Following this, subjects performed a potentiation and a control treatment in a counterbalanced order. The potentiation treatment culminated with subjects performing parallel back squats with a load equivalent to 70% 1- RM for three repetitions, following which they performed one countermovement vertical jump (CMJ) for maximal height every three minutes for a total of 10 jumps. During the control treatment, subjects performed only the CMJs. Jump height (JH) and vertical stiffness (VStiff) were calculated for each jump from the vertical force signal recorded from a force platform. There were no significant changes in JH or VStiff following the treatments and no significant differences in the responses between men and women (p > 0.05). Correlations between normalized 1-RM back squat load and the absolute change in JH and VStiff were small to moderate for both men and women, with most correlations being negative. Large variations in response to the back squats were noted in both men and women. The use of resistance exercises performed prior to a series of vertical jumps can result in improvements in performance in certain individuals, although the gains tend to be small and dependent upon the mechanical variable measured. There does not seem to be any differences between men and women in the response to dynamic potentiation protocols. Key points Substantial individual responses were noted in both men and women in response to the PAP protocol used in the present study. The choice of dependent variable influences the ef-ficacy of the PAP protocol, with JH and VStiff demonstrating disparate responses in individual sub-jects.Such individual responses may render such PAP protocols impractical for strength and conditioning practitioners as the protocols are likely to require in-dividualizing to each athlete. PMID:24149687
The acute effects of back squats on vertical jump performance in men and women.
Witmer, Chad A; Davis, Shala E; Moir, Gavin L
2010-01-01
The aim of the present study was to investigate the acute effects of performing back squats on subsequent performance during a series of vertical jumps in men and women. Twelve men and 12 women were tested on three separate occasions, the first of which was used to determine their 1-repetition maximum (1-RM) parallel back squat. Following this, subjects performed a potentiation and a control treatment in a counterbalanced order. The potentiation treatment culminated with subjects performing parallel back squats with a load equivalent to 70% 1- RM for three repetitions, following which they performed one countermovement vertical jump (CMJ) for maximal height every three minutes for a total of 10 jumps. During the control treatment, subjects performed only the CMJs. Jump height (JH) and vertical stiffness (VStiff) were calculated for each jump from the vertical force signal recorded from a force platform. There were no significant changes in JH or VStiff following the treatments and no significant differences in the responses between men and women (p > 0.05). Correlations between normalized 1-RM back squat load and the absolute change in JH and VStiff were small to moderate for both men and women, with most correlations being negative. Large variations in response to the back squats were noted in both men and women. The use of resistance exercises performed prior to a series of vertical jumps can result in improvements in performance in certain individuals, although the gains tend to be small and dependent upon the mechanical variable measured. There does not seem to be any differences between men and women in the response to dynamic potentiation protocols. Key pointsSubstantial individual responses were noted in both men and women in response to the PAP protocol used in the present study.The choice of dependent variable influences the ef-ficacy of the PAP protocol, with JH and VStiff demonstrating disparate responses in individual sub-jects.Such individual responses may render such PAP protocols impractical for strength and conditioning practitioners as the protocols are likely to require in-dividualizing to each athlete.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Duan, X; Grimes, J; Yu, L
Purpose: Focal spot blooming is an increase in the focal spot size at increased tube current and/or decreased tube potential. In this work, we evaluated the influence of tube current on the focal spot size at low kV for two CT systems, one of which used a tube designed to reduce blooming effects. Methods: A slit camera (10 micron slit) was used to measure focal spot size on two CT scanners from the same manufacturer (Siemens Somatom Force and Definition Flash) at 70 kV and low, medium and maximum tube currents, according to the capabilities of each system (Force: 100,more » 800 and 1300 mA; Flash: 100, 200 and 500 mA). Exposures were made with a stationary tube in service mode using a raised stand without table movement or flying focal spot technique. Focal spot size, nominally 0.8 and 1.2 mm, respectively, was measured parallel and perpendicular to the cathode-anode axis by calculating the full-width-at-half-maximum of the slit profile recording using computed radiographic plates. Results: Focal spot sizes perpendicular to the anode-cathode axis increased at the maximum mA by 5.7% on the Force and 39.1% on the Flash relative to that at the minimal mA, even though the mA was increased 13-fold on the Force and only 5- fold on the Flash. Focal spot size increased parallel to the anode-cathode axis by 70.4% on Force and 40.9% on Flash. Conclusion: For CT protocols using low kV, high mA is typically required. These protocols are relevant in children and smaller adults, and for dual-energy scanning. Technical measures to limit focal spot blooming are important in these settings to avoid reduced spatial resolution. The x-ray tube on a recently-introduced scanner appears to greatly reduce blooming effects, even at very high mA values. CHM has research support from Siemens Healthcare.« less
NASA Astrophysics Data System (ADS)
Ritzmann, Ramona; Freyler, Kathrin; Krause, Anne; Gollhofer, Albert
2016-10-01
Scopolamine is used to counteract motion sickness in parabolic flight (PF) experiments. Although the drug's anticholinergic properties effectively impede vomiting, recent studies document other sensory side-effects in the central nervous system that may considerably influence sensorimotor performance. This study aimed to quantify such effects in order to determine if they are of methodological and operational significance for sensorimotor control. Ten subjects of a PF campaign received a weight-sex-based dose of a subcutaneous scopolamine injection. Sensorimotor performance was recorded before medication, 20min, 2h and 4h after injection in four space-relevant paradigms: balance control in one-leg stance with eyes open (protocol 1) and closed as well as force-generating capacity in countermovement jumps and hops (protocol 2). Postural sway, forces and joint angles were recorded. Neuromuscular control was assessed by electromyography and peripheral nerve stimulation; H-reflexes and M-waves were used to monitor spinal excitability of the Ia afferent reflex circuitry and maximal motor output. (1) H-reflex amplitudes, latencies and functional reflexes remained unchanged after scopolamine injection. (2) M-waves, neuromuscular activation intensities and antagonistic muscle coordination did not change with scopolamine administration. (3) Balance performance and force-generating capacity were not impeded by scopolamine. We found no evidence for changes in sensorimotor control in response to scopolamine injection. Sensory processing of daily relevant reflexes, spinal excitability, maximal motor output and performance parameters were not sensitive to the medication. We conclude that scopolamine administration can be used to counteract motion sickness in PF without methodological and operational concerns or interference regarding sensorimotor skills associated with neuromuscular control.
Developments in Assisting Countries in Implementing the IAEA Additional Protocol
DOE Office of Scientific and Technical Information (OSTI.GOV)
Killinger, Mark H.; Hansen, Linda H.; Cain, Ronald A.
In 2008, the U.S. Department of Energy (DOE) began assisting selected non-nuclear weapon states in planning and preparing for implementation of the International Atomic Energy Agency’s Additional Protocol (AP). Since then, the AP international implementation program has contributed to the substantial progress made by Vietnam, Thailand, Iraq, and Malaysia in preparing for entry-into-force of the AP. An overall engagement plan has been developed with components designed to train government AP implementing agencies, inform policy makers, conduct outreach to industry and universities, make AP reporting software available and useful, and plan a detailed approach for implementing the declaration and complementary accessmore » provisions of the AP. DOE recently began collaborating with Indonesia, which has already entered the AP into force, requiring a second method of engagement somewhat different from that taken with countries that have not entered the AP into force. The AP international implementation program, administered by the International Nuclear Safeguards and Engagement Program, is working more closely with DOE’s International Nonproliferation Export Control Program to ensure countries are aware of and prepared to implement the export/import provisions of the AP. As the AP implementation program matures and helps move countries closer to entry-into-force or improved AP implementation, it is identifying characteristics of a country’s “end-state” that indicate that DOE assistance is no longer required. The U.S. AP Implementation Act and Senate Resolution of Ratification require the Administration to report annually to Congress on measures taken to achieve the adoption of the AP in non-nuclear weapon states. DOE’s AP international implementation program is a significant part of these measures. This paper describes recent developments to increase the scope and effectiveness of the program.« less
Mysore, Venkataram; Mahadevappa, Omprakash H.; Barua, Shyamanta; Majid, Imran; Viswanath, Vishalakshi; Bhat, Ramesh M.; Talwar, Suresh; Thurakkal, Salim; Aurangabadkar, Sanjeev J.; Chatterjee, Manas; Ganjoo, Anil
2017-01-01
Background: Currently, the standard protocol regarding the performance of procedures on patients receiving or having recently received isotretinoin (13-cis-retinoic acid) states that the procedures should not be performed. The recommendations in standard books and drug insert require discontinuation of isotretinoin for 6 months before performing cosmetic procedures, including waxing, dermabrasion, chemical peels, laser procedures, or incisional and excisional cold-steel surgery. These recommendations have been followed for over two decades despite little evidence for the stated increased risk of scarring. Objective: The Association of Cutaneous Surgeons (I) constituted a task force to review the evidence and to recommend consensus guidelines regarding the safety of skin procedures, including resurfacing, energy-device treatments, and dermatosurgical procedures in patients with concurrent or recent isotretinoin administration. Materials and Methods: Data were extracted from the literature through a PubMed search using the keywords “isotretinoin,” “safety,” “scarring,” “keloids,” “hypertrophic scarring,” and “pigmentation.” The evidence was then labeled and circulated to all members of task force for review. Results: The task force is of the opinion that there is insufficient evidence to support the current protocol of avoiding and delaying treatments in the patient group under consideration and recommends that the current practice should be discontinued. The task force concludes that performing procedures such as laser hair removal, fractional lasers for aging and acne scarring, lasers for pigmented skin lesions, fractional radio-frequency microneedling, superficial and medium-depth peels, microdermabrasion, dermaroller, biopsies, radio-frequency ablation, and superficial excisions is safe in patients with concurrent or recent isotretinoin administration. PMID:29491653
In the years since publication of the U.S. Air Force and U.S. EPA technical protocols for evaluating Monitored Natural Attenuation, MNA had found widespread application to organic contaminants in ground water. These documents were issued more than a decade ago; the science has m...
Scalable Authenticated Tree Based Group Key Exchange for Ad-Hoc Groups
NASA Astrophysics Data System (ADS)
Desmedt, Yvo; Lange, Tanja; Burmester, Mike
Task-specific groups are often formed in an ad-hoc manner within large corporate structures, such as companies. Take the following typical scenario: A director decides to set up a task force group for some specific project. An order is passed down the hierarchy where it finally reaches a manager who selects some employees to form the group. The members should communicate in a secure way and for efficiency, a symmetric encryption system is chosen. To establish a joint secret key for the group, a group key exchange (GKE) protocol is used. We show how to use an existing Public Key Infrastructure (PKI) to achieve authenticated GKE by modifying the protocol and particularly by including signatures.
Incidence and severity of root resorption in orthodontically moved premolars in dogs.
Maltha, J C; van Leeuwen, E J; Dijkman, G E H M; Kuijpers-Jagtman, A M
2004-05-01
To study treatment-related factors for external root resorption during orthodontic tooth movement. An experimental animal study. Department of Orthodontics and Oral Biology, University Medical Centre Nijmegen, The Netherlands. Twenty-four young adult beagle dogs. Mandibular premolars were bodily moved with continuous or intermittent controlled orthodontic forces of 10, 25, 50, 100, or 200 cN according to standardized protocols. At different points in time histomorphometry was performed to determine the severity of root resorption. Prevalence of root resorptions, defined as microscopically visible resorption lacunae in the dentin. Severity of resorption was defined by the length, relative length, depth, and surface area of each resorption area. The incidence of root resorption increased with the duration of force application. After 14-17 weeks of force application root resorption was found at 94% of the root surfaces at pressure sides. The effect of force magnitude on the severity of root resorption was not statistically significant. The severity of root resorption was highly related to the force regimen. Continuous forces caused significantly more severe root resorption than intermittent forces. A strong correlation (0.60 < r < 0.68) was found between the amount of tooth movement and the severity of root resorption. Root resorption increases with the duration of force application. The more teeth are displaced, the more root resorption will occur. Intermittent forces cause less severe root resorption than continuous forces, and force magnitude is probably not decisive for root resorption.
Single-leg hop testing following fatiguing exercise: reliability and biomechanical analysis.
Augustsson, J; Thomeé, R; Lindén, C; Folkesson, M; Tranberg, R; Karlsson, J
2006-04-01
A fatiguing exercise protocol was combined with single-leg hop testing to improve the possibilities of evaluating the effects of training or rehabilitation interventions. In the first test-retest experiment, 11 healthy male subjects performed two trials of single-leg hops under three different test conditions: non-fatigued and following fatiguing exercise, which consisted of unilateral weight machine knee extensions at 80% and 50%, respectively, of 1 repetition maximum (1 RM) strength. Intraclass correlation coefficients ranged from 0.75 to 0.98 for different hop test conditions, indicating that all tests were reliable. For the second experiment, eight healthy male subjects performed the fatiguing exercise protocol to investigate how fatigue influences lower-extremity joint kinematics and kinetics during single-leg hops. Hip, knee and ankle joint angles, moments and powers, as well as ground-reaction forces were recorded with a six-camera, motion-capture system and a force platform. Recovery of hop performance following the fatiguing exercise was also measured. During the take-off for the single-leg hops, hip and knee flexion angles, generated powers for the knee and ankle joints, and ground-reaction forces decreased for the fatigued hop conditions compared with the non-fatigued condition (P<0.05). Compared with landing during the non-fatigued condition, hip moments and ground-reaction forces were lower for the fatigued hop conditions (P<0.05). The negative joint power was two to three times greater for the knee than for the hip and five to 10 times greater for the knee than for the ankle during landing for all test conditions (P<0.05). Most measured variables had recovered three minutes post-exercise. It is concluded that the fatiguing exercise protocol combined with single-leg hop testing was a reliable method for investigating functional performance under fatigued test conditions. Further, subjects utilized an adapted hop strategy, which employed less hip and knee flexion and generated powers for the knee and ankle joints during take-off, and less hip joint moments during landing under fatigued conditions. The large negative power values observed at the knee joint during the landing phase of the single-leg hop, during which the quadriceps muscle activates eccentrically, indicate that not only hop distance but also the ability to perform successful landings should be investigated when assessing dynamic knee function.
Hydrofluorocarbon (HFC) Scenarios, Climate Effects and the Montreal Protocol
NASA Astrophysics Data System (ADS)
Velders, G. J. M.; Fahey, D. W.; Daniel, J. S.
2016-12-01
The Montreal Protocol has reduced the use of ozone-depleting substances by more than 95% from its peak levels in the 1980s. As a direct result the use of hydrofluorocarbons (HFCs) as substitute compounds has increased significantly. National regulations to limit HFC use have been adopted recently in the European Union, Japan and USA, and four proposals have been submitted to amend the Montreal Protocol to substantially reduce growth in HFC use. The Parties of the Montreal Protocol have discussed these proposals during their meetings in 2016. The effects of the national regulations and Montreal Protocol amendment proposals on climate forcings and surface temperatures will be presented. Global scenarios of HFC emissions reach 4.0-5.3 GtCO2-eq yr-1 in 2050, which corresponds to a projected growth from 2015 to 2050 which is 9% to 29% of that for CO2 over the same time period. In 2050, in percent of global HFC emissions, China ( 30%), India and the rest of Asia ( 25%), Middle East and northern Africa ( 10%), and USA ( 10%) are the principal source regions; and refrigeration and stationary air conditioning are the major use sectors. Calculated baseline emissions are reduced by 90% in 2050 by implementing the North America Montreal Protocol amendment proposal. This corresponds to a reduction in surface temperature attributed to HFCs from 0.1 oC to 0.04 oC in 2050 and from 0.3-0.4 oC to 0.02 oC in 2100.
Acute Effect of Different Combined Stretching Methods on Acceleration and Speed in Soccer Players.
Amiri-Khorasani, Mohammadtaghi; Calleja-Gonzalez, Julio; Mogharabi-Manzari, Mansooreh
2016-04-01
The purpose of this study was to investigate the acute effect of different stretching methods, during a warm-up, on the acceleration and speed of soccer players. The acceleration performance of 20 collegiate soccer players (body height: 177.25 ± 5.31 cm; body mass: 65.10 ± 5.62 kg; age: 16.85 ± 0.87 years; BMI: 20.70 ± 5.54; experience: 8.46 ± 1.49 years) was evaluated after different warm-up procedures, using 10 and 20 m tests. Subjects performed five types of a warm-up: static, dynamic, combined static + dynamic, combined dynamic + static, and no-stretching. Subjects were divided into five groups. Each group performed five different warm-up protocols in five non-consecutive days. The warm-up protocol used for each group was randomly assigned. The protocols consisted of 4 min jogging, a 1 min stretching program (except for the no-stretching protocol), and 2 min rest periods, followed by the 10 and 20 m sprint test, on the same day. The current findings showed significant differences in the 10 and 20 m tests after dynamic stretching compared with static, combined, and no-stretching protocols. There were also significant differences between the combined stretching compared with static and no-stretching protocols. We concluded that soccer players performed better with respect to acceleration and speed, after dynamic and combined stretching, as they were able to produce more force for a faster execution.
Recovery of gait after quadriceps muscle fatigue.
Barbieri, Fabio Augusto; Beretta, Stephannie Spiandor; Pereira, Vinicius A I; Simieli, Lucas; Orcioli-Silva, Diego; dos Santos, Paulo Cezar Rocha; van Dieën, Jaap H; Gobbi, Lilian Teresa Bucken
2016-01-01
The aim of this study was to investigate the effect of recovery time after quadriceps muscle fatigue on gait in young adults. Forty young adults (20-40 years old) performed three 8-m gait trials at preferred velocity before and after muscle fatigue, and after 5, 10 and 20min of passive rest. In addition, at each time point, two maximal isometric voluntary contractions were preformed. Muscle fatigue was induced by repeated sit-to-stand transfers until task failure. Spatio-temporal, kinetic and muscle activity parameters, measured in the central stride of each trial, were analyzed. Data were compared between before and after the muscle fatigue protocol and after the recovery periods by one-way repeated measures ANOVA. The voluntary force was decreased after the fatigue protocol (p<0.001) and after 5, 10 and 20min of recovery compared to before the fatigue protocol. Step width (p<0.001) and RMS of biceps femoris (p<0.05) were increased immediately after the fatigue protocol and remained increased after the recovery periods. In addition, stride duration was decreased immediately after the fatigue protocol compared to before and to after 10 and 20min of rest (p<0.001). The anterior-posterior propulsive impulse was also decreased after the fatigue protocol (p<0.001) and remained low after 5, 10 and 20min of rest. We conclude that 20min is not enough to see full recovery of gait after exhaustive quadriceps muscle fatigue. Copyright © 2015 Elsevier B.V. All rights reserved.
Fleming, Braden C.; Brady, Mark F.; Bradley, Michael P.; Banerjee, Rahul; Hulstyn, Michael J.; Fadale, Paul D.
2008-01-01
Purpose To document the tibiofemoral (TF) compression forces produced during clinical initial graft tension protocols. Methods An image analysis system was used to track the position of the tibia relative to the femur in 11 cadaver knees. TF compression forces were quantified using thin-film pressure sensors. Prior to performing ACL reconstructions with patellar tendon grafts, measurements of TF compression force were obtained from the ACL-intact knee with knee flexion. ACL reconstructions were then performed using “force-based” and “laxity-based” graft tension approaches. Within each approach, high- and low-tension conditions were compared to the ACL-intact condition over the range of knee flexion angles. Results The TF compression forces for all initial graft tension conditions were significantly greater than that of the normal knee when the knee was in full extension (0°). The TF compression forces when using the laxity-based approach were greater than those produced with the force-based approach. However the laxity-based approach was necessary to restore normal laxity at the time of surgery. Conclusions The initial graft tension conditions produce different TF compressive force profiles at the time of surgery. A compromise must be made between restoring knee laxity or TF compressive forces when reconstructing the ACL with patellar tendon graft. Clinical Relevance The TF compression forces were greater in the ACL-reconstructed knee for all the initial graft tension conditions when compared to the ACL-intact knee, and that clinically relevant initial graft tension conditions produce different TF compressive forces. PMID:18760214
2016-01-01
Molecular mechanics force fields that explicitly account for induced polarization represent the next generation of physical models for molecular dynamics simulations. Several methods exist for modeling induced polarization, and here we review the classical Drude oscillator model, in which electronic degrees of freedom are modeled by charged particles attached to the nuclei of their core atoms by harmonic springs. We describe the latest developments in Drude force field parametrization and application, primarily in the last 15 years. Emphasis is placed on the Drude-2013 polarizable force field for proteins, DNA, lipids, and carbohydrates. We discuss its parametrization protocol, development history, and recent simulations of biologically interesting systems, highlighting specific studies in which induced polarization plays a critical role in reproducing experimental observables and understanding physical behavior. As the Drude oscillator model is computationally tractable and available in a wide range of simulation packages, it is anticipated that use of these more complex physical models will lead to new and important discoveries of the physical forces driving a range of chemical and biological phenomena. PMID:26815602
Arsenovic, Paul T; Bathula, Kranthidhar; Conway, Daniel E
2017-04-11
The LINC complex has been hypothesized to be the critical structure that mediates the transfer of mechanical forces from the cytoskeleton to the nucleus. Nesprin-2G is a key component of the LINC complex that connects the actin cytoskeleton to membrane proteins (SUN domain proteins) in the perinuclear space. These membrane proteins connect to lamins inside the nucleus. Recently, a Förster Resonance Energy Transfer (FRET)-force probe was cloned into mini-Nesprin-2G (Nesprin-TS (tension sensor)) and used to measure tension across Nesprin-2G in live NIH3T3 fibroblasts. This paper describes the process of using Nesprin-TS to measure LINC complex forces in NIH3T3 fibroblasts. To extract FRET information from Nesprin-TS, an outline of how to spectrally unmix raw spectral images into acceptor and donor fluorescent channels is also presented. Using open-source software (ImageJ), images are pre-processed and transformed into ratiometric images. Finally, FRET data of Nesprin-TS is presented, along with strategies for how to compare data across different experimental groups.
Importance of contraction history on muscle force of porcine urinary bladder smooth muscle.
Menzel, Robin; Böl, Markus; Siebert, Tobias
2017-02-01
The purpose of this study was to provide a comprehensive dataset of porcine urinary bladder smooth muscle properties. Particularly, the history dependence of force production, namely force depression (FD) following shortening and force enhancement (FE) following stretch, was analysed. During active micturition, the circumference of the urinary bladder changes enormously. Thus, FD might be an important phenomenon during smooth muscle contraction. Electrically stimulated, intact urinary bladder strips from pigs (n = 10) were suspended in an aerated-filled organ bath, and different isometric, isotonic, and isokinetic contraction protocols were performed to determine the force-length and the force-velocity relation. FD and FE were assessed in concentric and eccentric contractions with different ramp lengths and ramp velocities. Bladder smooth muscles exhibit considerable amounts of FD and FE. The amount of FD increased significantly with ramp length, while FE did not change. However, FE and FD were independent of ramp velocity. The results imply that smooth muscle bladder strips exhibit similar muscle properties and history-dependent behaviour compared to striated muscles. The provided dataset of muscle properties is important for bladder modelling as well as for the analyses and interpretation of dynamic bladder filling and voiding.
Contractile function is unaltered in diaphragm from mice lacking calcium release channel isoform 3
NASA Technical Reports Server (NTRS)
Clancy, J. S.; Takeshima, H.; Hamilton, S. L.; Reid, M. B.
1999-01-01
Skeletal muscle expresses at least two isoforms of the calcium release channel in the sarcoplasmic reticulum (RyR1 and RyR3). Whereas the function of RyR1 is well defined, the physiological significance of RyR3 is unclear. Some authors have suggested that RyR3 participates in excitation-contraction coupling and that RyR3 may specifically confer resistance to fatigue. To test this hypothesis, we measured contractile function of diaphragm strips from adult RyR3-deficient mice (exon 2-targeted mutation) and their heterozygous and wild-type littermates. In unfatigued diaphragm, there were no differences in isometric contractile properties (twitch characteristics, force-frequency relationships, maximal force) among the three groups. Our fatigue protocol (30 Hz, 0.25 duty cycle, 37 degrees C) depressed force to 25% of the initial force; however, lack of RyR3 did not accelerate the decline in force production. The force-frequency relationship was shifted to higher frequencies and was depressed in fatigued diaphragm; lack of RyR3 did not exaggerate these changes. We therefore provide evidence that RyR3 deficiency does not alter contractile function of adult muscle before, during, or after fatigue.
TVD, Thirsk collects data during LMS-1 Spacelab mission
1996-07-09
STS078-304-018 (20 June - 7 July 1996) --- Payload specialist Robert B. Thirsk, representing the Canadian Space Agency (CSA), performs a test on his arm using the Torque Velocity Dynamometer (TVD). Dr. Thirsk was measuring changes in muscle forces of the bicep and tricep in this particular view. The TVD hardware is also used to measure leg muscle forces and velocity at the ankle and elbow joints. Crew members for the mission performed all experiment protocols prior to flight to develop a baseline and will also perform post-flight tests to complete the analysis. Additionally, muscle biopsies were taken before the flight and will be conducted after the flight.
Characterization of Structural and Configurational Properties of DNA by Atomic Force Microscopy.
Meroni, Alice; Lazzaro, Federico; Muzi-Falconi, Marco; Podestà, Alessandro
2018-01-01
We describe a method to extract quantitative information on DNA structural and configurational properties from high-resolution topographic maps recorded by atomic force microscopy (AFM). DNA molecules are deposited on mica surfaces from an aqueous solution, carefully dehydrated, and imaged in air in Tapping Mode. Upon extraction of the spatial coordinates of the DNA backbones from AFM images, several parameters characterizing DNA structure and configuration can be calculated. Here, we explain how to obtain the distribution of contour lengths, end-to-end distances, and gyration radii. This modular protocol can be also used to characterize other statistical parameters from AFM topographies.
Jesse, Stephen; Kalinin, Sergei V; Nikiforov, Maxim P
2013-07-09
An approach for the thermomechanical characterization of phase transitions in polymeric materials (polyethyleneterephthalate) by band excitation acoustic force microscopy is developed. This methodology allows the independent measurement of resonance frequency, Q factor, and oscillation amplitude of a tip-surface contact area as a function of tip temperature, from which the thermal evolution of tip-surface spring constant and mechanical dissipation can be extracted. A heating protocol maintained a constant tip-surface contact area and constant contact force, thereby allowing for reproducible measurements and quantitative extraction of material properties including temperature dependence of indentation-based elastic and loss moduli.
Hautier, C; Bonnefoy, M
2007-07-01
Aging is associated with a reduction in physical fitness, with loss of muscular force and endurance. Physical activity has been demonstrated to provide substantial health benefits and to maintain functional independence and improve quality of life in older adults. Resistance training has a significant effect on muscle mass and force whereas endurance training increases oxygen transport and consumption capacities. This article presents training methods used in the literature and their associated effects in order to adapt training protocols to older populations. To maximise benefits from adoption of a program to which the patient can adhere for long time, it is important to tailor the exercise prescription to the individual.
Options to Accelerate Ozone Recovery: Ozone and Climate Benefits
NASA Technical Reports Server (NTRS)
Fleming, E. L.; Daniel, J. S.; Portmann, R. W.; Velders, G. J. M.; Jackman, C. H.; Ravishankara, A. R.
2010-01-01
The humankind or anthropogenic influence on ozone primarily originated from the chlorofluorocarbons and halons (chlorine and bromine). Representatives from governments have met periodically over the years to establish international regulations starting with the Montreal Protocol in 1987, which greatly limited the release of these ozone-depleting substances (DDSs). Two global models have been used to investigate the impact of hypothetical reductions in future emissions of ODSs on total column ozone. The investigations primarily focused on chlorine- and bromine-containing gases, but some computations also included nitrous oxide (N2O). The Montreal Protocol with ODS controls have been so successful that further regulations of chlorine- and bromine-containing gases could have only a fraction of the impact that regulations already in force have had. if all anthropogenic ODS emissions were halted beginning in 2011, ozone is calculated to be higher by about 1-2% during the period 2030-2100 compared to a case of no additional ODS restrictions. Chlorine- and bromine-containing gases and nitrous oxide are also greenhouse gases and lead to warming of the troposphere. Elimination of N 20 emissions would result in a reduction of radiative forcing of 0.23 W/sq m in 2100 than presently computed and destruction of the CFC bank would produce a reduction in radiative forcing of 0.005 W/sq m in 2100. This paper provides a quantitative way to consider future regulations of the CFC bank and N 20 emissions
Novel methods of imaging and analysis for the thermoregulatory sweat test.
Carroll, Michael Sean; Reed, David W; Kuntz, Nancy L; Weese-Mayer, Debra Ellyn
2018-06-07
The thermoregulatory sweat test (TST) can be central to the identification and management of disorders affecting sudomotor function and small sensory and autonomic nerve fibers, but the cumbersome nature of the standard testing protocol has prevented its widespread adoption. A high resolution, quantitative, clean and simple assay of sweating could significantly improve identification and management of these disorders. Images from 89 clinical TSTs were analyzed retrospectively using two novel techniques. First, using the standard indicator powder, skin surface sweat distributions were determined algorithmically for each patient. Second, a fundamentally novel method using thermal imaging of forced evaporative cooling was evaluated through comparison with the standard technique. Correlation and receiver operating characteristic analyses were used to determine the degree of match between these methods, and the potential limits of thermal imaging were examined through cumulative analysis of all studied patients. Algorithmic encoding of sweating and non-sweating regions produces a more objective analysis for clinical decision making. Additionally, results from the forced cooling method correspond well with those from indicator powder imaging, with a correlation across spatial regions of -0.78 (CI: -0.84 to -0.71). The method works similarly across body regions, and frame-by-frame analysis suggests the ability to identify sweating regions within about 1 second of imaging. While algorithmic encoding can enhance the standard sweat testing protocol, thermal imaging with forced evaporative cooling can dramatically improve the TST by making it less time-consuming and more patient-friendly than the current approach.
Bilateral movements increase sustained extensor force in the paretic arm.
Kang, Nyeonju; Cauraugh, James H
2018-04-01
Muscle weakness in the extensors poststroke is a common motor impairment. Unfortunately, research is unclear on whether bilateral movements increase extensor force production in the paretic arm. This study investigated sustained force production while stroke individuals maximally extended their wrist and fingers on their paretic arm. Specifically, we determined isometric force production in three conditions: (a) unilateral paretic arm, (b) unilateral nonparetic arm, and (c) bilateral (both arms executing the same movement simultaneously). Seventeen chronic stroke patients produced isometric sustained force by executing wrist and fingers extension in unilateral and bilateral contraction conditions. Mean force, force variability (coefficient of variation), and signal-to-noise ratio were calculated for each contraction condition. Analysis of two-way (Arm × Type of Condition: 2 × 2; Paretic or Nonparetic Arm × Unilateral or Bilateral Conditions) within-subjects ANOVAs revealed that the bilateral condition increased sustained force in the paretic arm, but reduced sustained force in the nonparetic arm. Further, although the paretic arm exhibited more force variability and less signal-to-noise ratio than the nonparetic arm during a unilateral condition, there were no differences when participants simultaneously executed isometric contractions with both arms. Our unique findings indicate that bilateral contractions transiently increased extensor force in the paretic arm. Implications for Rehabilitation Bilateral movements increased isometric wrsit extensor force in paretic arms and redcued force in nonparetic arms versus unilateral movements. Both paretic and nonparetic arms produced similar force variability and signal-to-noise ratio during bilateral movements. Increased sustained force in the paretic arm during the bilateral condition indicates that rehabilitation protocols based on bilateral movements may be beneficial for functional recovery.
Acute Effects of Drop-Jump Protocols on Explosive Performances of Elite Handball Players.
Dello Iacono, Antonio; Martone, Domenico; Padulo, Johnny
2016-11-01
Dello Iacono, A, Martone, D, and Padulo, J. Acute effects of drop-jump protocols on explosive performances of elite handball players. J Strength Cond Res 30(11): 3122-3133, 2016-This study aimed to assess the acute effects of vertical and horizontal drop jump-based postactivation potentiation (PAP) protocols on neuromuscular abilities in tasks such as jumping, sprinting, and change of direction (COD). Eighteen handball players were assessed before and after PAP regimens, consisting of either vertical single-leg drop-jumps (VDJ) or horizontal single-leg drop-jumps (HDJ) single-leg drop-jumps, on countermovement jump (CMJ), linear sprint, shuttle sprint, and agility performance. The HDJ led to greater improvement of the COD performance in comparison with the VDJ (-6.8 vs. -1.3%; p ≤ 0.05), whereas the VDJ caused greater improvement in the CMJ task compared with the HDJs (+6.5 vs. +1%; p ≤ 0.05). Moreover, the VDJ regimens compared with HDJ induced greater changes in most of the kinetic variables associated with vertical jumping performance, such as peak ground reaction forces (+9.6 vs. +1.3%), vertical displacement (-13.4 vs. -5.3%), leg-spring stiffness (+18.6 vs. +3.6%), contact time (-9.2 vs. -1.3%), and reactive strength index (+7.3 vs. +2.4%) (all comparisons with p ≤ 0.05). Conversely, the HDJ regimens were able to improve the COD performance only by reducing the contact time on COD more than the VDJ (-13.3 vs. -2.4% with p ≤ 0.05). The results showed that both PAPs were able to improve the performances that specifically featured similar force-orientation production. This investigation showed the crucial role that different and specific PAP regimens play in optimizing related functional performances. Specifically oriented vertical and horizontal single-leg drop-jump protocols represent viable means for achieving enhanced explosive-based tasks such as jumping and COD.
Mechanical Characterization of Partially Crystallized Sphere Packings
NASA Astrophysics Data System (ADS)
Hanifpour, M.; Francois, N.; Vaez Allaei, S. M.; Senden, T.; Saadatfar, M.
2014-10-01
We study grain-scale mechanical and geometrical features of partially crystallized packings of frictional spheres, produced experimentally by a vibrational protocol. By combining x-ray computed tomography, 3D image analysis, and discrete element method simulations, we have access to the 3D structure of internal forces. We investigate how the network of mechanical contacts and intergranular forces change when the packing structure evolves from amorphous to near perfect crystalline arrangements. We compare the behavior of the geometrical neighbors (quasicontracts) of a grain to the evolution of the mechanical contacts. The mechanical coordination number Zm is a key parameter characterizing the crystallization onset. The high fluctuation level of Zm and of the force distribution in highly crystallized packings reveals that a geometrically ordered structure still possesses a highly random mechanical backbone similar to that of amorphous packings.
Investigating single molecule adhesion by atomic force spectroscopy.
Stetter, Frank W S; Kienle, Sandra; Krysiak, Stefanie; Hugel, Thorsten
2015-02-27
Atomic force spectroscopy is an ideal tool to study molecules at surfaces and interfaces. An experimental protocol to couple a large variety of single molecules covalently onto an AFM tip is presented. At the same time the AFM tip is passivated to prevent unspecific interactions between the tip and the substrate, which is a prerequisite to study single molecules attached to the AFM tip. Analyses to determine the adhesion force, the adhesion length, and the free energy of these molecules on solid surfaces and bio-interfaces are shortly presented and external references for further reading are provided. Example molecules are the poly(amino acid) polytyrosine, the graft polymer PI-g-PS and the phospholipid POPE (1-palmitoyl-2-oleoyl-sn-glycero-3-phosphoethanolamine). These molecules are desorbed from different surfaces like CH3-SAMs, hydrogen terminated diamond and supported lipid bilayers under various solvent conditions. Finally, the advantages of force spectroscopic single molecule experiments are discussed including means to decide if truly a single molecule has been studied in the experiment.
Investigating Single Molecule Adhesion by Atomic Force Spectroscopy
Stetter, Frank W. S.; Kienle, Sandra; Krysiak, Stefanie; Hugel, Thorsten
2015-01-01
Atomic force spectroscopy is an ideal tool to study molecules at surfaces and interfaces. An experimental protocol to couple a large variety of single molecules covalently onto an AFM tip is presented. At the same time the AFM tip is passivated to prevent unspecific interactions between the tip and the substrate, which is a prerequisite to study single molecules attached to the AFM tip. Analyses to determine the adhesion force, the adhesion length, and the free energy of these molecules on solid surfaces and bio-interfaces are shortly presented and external references for further reading are provided. Example molecules are the poly(amino acid) polytyrosine, the graft polymer PI-g-PS and the phospholipid POPE (1-palmitoyl-2-oleoyl-sn-glycero-3-phosphoethanolamine). These molecules are desorbed from different surfaces like CH3-SAMs, hydrogen terminated diamond and supported lipid bilayers under various solvent conditions. Finally, the advantages of force spectroscopic single molecule experiments are discussed including means to decide if truly a single molecule has been studied in the experiment. PMID:25867282
A real-time haptic interface for interventional radiology procedures.
Moix, Thomas; Ilic, Dejan; Fracheboud, Blaise; Zoethout, Jurjen; Bleuler, Hannes
2005-01-01
Interventional Radiology (IR) is a minimally-invasive surgery technique (MIS) where guidewires and catheters are steered in the vascular system under X-ray imaging. In order to perform these procedures, a radiologist has to be correctly trained to master hand-eye coordination, instrument manipulation and procedure protocols. This paper proposes a computer-assisted training environment dedicated to IR. The system is composed of a virtual reality (VR) simulation of the anatomy of the patient linked to a robotic interface providing haptic force feedback.The paper focuses on the requirements, design and prototyping of a specific part of the haptic interface dedicated to catheters. Translational tracking and force feedback on the catheter is provided by two cylinders forming a friction drive arrangement. The whole friction can be set in rotation with an additional motor providing torque feedback. A force and a torque sensor are integrated in the cylinders for direct measurement on the catheter enabling disturbance cancellation with a close-loop force control strategy.
Worldwide Emerging Environmental Issues Affecting the U.S. Military. November 2006 Report
2006-11-01
should follow this development for potential improved environmental biological weapons surveillance systems. Source: Researchers use laser...Protocol V on Explosive Remnants of War (ERW) of the Convention on Certain Conventional Weapons came into force on 12 November 2006, almost three...potentials for nanotech weapons , create unique problems of proliferation, health effects, environmental impacts, and post-conflict cleanups that are
Connecting the Force from Space: The IRIS Joint Capability Technology Demonstration
2010-01-01
the Joint in Joint Capability Technology Demonstration, we have two sponsors, both U.S. Strategic Command and the Defense Information Systems...Capability Technology Demonstration will provide an excellent source of data on space-based Internet Protocol net- working. Operational... Internet Routing in Space Joint Capability Technology Demonstration Operational Manager, Space and Missile Defense Battle Lab, Colorado Springs
OCONUS Compliance Assessment Protocols Air Force Supplement
2009-09-01
that have environmental impacts (i.e., construction, mission changes, process/activity changes). Are environmental surveys and construction site...how and where does disposal occur? Has the installation conducted a complete asbestos survey ? If yes, what the date of the most recent... survey ? (Please provide a copy for the assessment team.) Has the installation prepared, coordinated, and executed an Asbestos Management Plan
The President’s Identity Theft Task Force: Combating Identity Theft a Strategic Plan
2007-04-11
27 a. Safeguarding of Information in the Public Sector ............... 27 b. Responding to Data Breaches in the Public...72 APPENDICES Appendix A: Identity Theft Task Force’s Guidance Memorandum on Data Breach Protocol...government, and the private sector. Consumers, overwhelmed with weekly media reports of data breaches , feel vulnerable and uncertain of how to protect
Observing human movements helps decoding environmental forces.
Zago, Myrka; La Scaleia, Barbara; Miller, William L; Lacquaniti, Francesco
2011-11-01
Vision of human actions can affect several features of visual motion processing, as well as the motor responses of the observer. Here, we tested the hypothesis that action observation helps decoding environmental forces during the interception of a decelerating target within a brief time window, a task intrinsically very difficult. We employed a factorial design to evaluate the effects of scene orientation (normal or inverted) and target gravity (normal or inverted). Button-press triggered the motion of a bullet, a piston, or a human arm. We found that the timing errors were smaller for upright scenes irrespective of gravity direction in the Bullet group, while the errors were smaller for the standard condition of normal scene and gravity in the Piston group. In the Arm group, instead, performance was better when the directions of scene and target gravity were concordant, irrespective of whether both were upright or inverted. These results suggest that the default viewer-centered reference frame is used with inanimate scenes, such as those of the Bullet and Piston protocols. Instead, the presence of biological movements in animate scenes (as in the Arm protocol) may help processing target kinematics under the ecological conditions of coherence between scene and target gravity directions.
Rigidity and retention of ceramic root canal posts.
Purton, D G; Love, R M; Chandler, N P
2000-01-01
Ceramic root-canal posts offer potential advantages over other types with respect to aesthetics and biocompatibility. Any post must be sufficiently rigid and retentive to withstand functional forces. Ceraposts (1.2 mm coronal diameter, ceramic, tapering, smooth posts) and Paraposts (1.25 mm, stainless-steel, parallel, serrated posts) were tested for rigidity by means of a three-point bending test. To test retention in roots, ceramic posts were cemented using one of three protocols: (1) glass-ionomer cement, (2) silane coupling agent and resin cement, or (3) sandblasted post surface, silane coupling agent, and resin cement. Stainless-steel posts were cemented with resin. The tensile force required to dislodge the posts, following four weeks of storage in water, was recorded. Data were compared using Student's t-test and Mann-Whitney U analysis. Ceraposts were significantly more rigid than Paraposts (p < 0.001). Paraposts cemented with resin were significantly more strongly retained than Ceraposts following any cementation protocol (p < 0.001). Retention of the ceramic posts was significantly greater with a silane coupling agent and resin cement than with glass-ionomer cement (p < 0.001). Sandblasting the ceramic posts produced variable results and needs further investigation before it could be recommended.
Taeger, Christian D.; Friedrich, Oliver; Dragu, Adrian; Weigand, Annika; Hobe, Frieder; Drechsler, Caroline; Geppert, Carol I.; Arkudas, Andreas; Münch, Frank; Buchholz, Rainer; Pollmann, Charlotte; Schramm, Axel; Birkholz, Torsten; Horch, Raymund E.; Präbst, Konstantin
2015-01-01
Preventing ischemia-related cell damage is a priority when preserving tissue for transplantation. Perfusion protocols have been established for a variety of applications and proven to be superior to procedures used in clinical routine. Extracorporeal perfusion of muscle tissue though cumbersome is highly desirable since it is highly susceptible to ischemia-related damage. To show the efficacy of different perfusion protocols external field stimulation can be used to immediately visualize improvement or deterioration of the tissue during active and running perfusion protocols. This method has been used to show the superiority of extracorporeal perfusion using porcine rectus abdominis muscles perfused with heparinized saline solution. Perfused muscles showed statistically significant higher ability to exert force compared to nonperfused ones. These findings can be confirmed using Annexin V as marker for cell damage, perfusion of muscle tissue limits damage significantly compared to nonperfused tissue. The combination of extracorporeal perfusion and external field stimulation may improve organ conservation research. PMID:26145230
Transient quantum fluctuation theorems and generalized measurements
NASA Astrophysics Data System (ADS)
Prasanna Venkatesh, B.; Watanabe, Gentaro; Talkner, Peter
2014-01-01
The transient quantum fluctuation theorems of Crooks and Jarzynski restrict and relate the statistics of work performed in forward and backward forcing protocols. So far, these theorems have been obtained under the assumption that the work is determined by two projective energy measurements, one at the end, and the other one at the beginning of each run of the protocol. We found that one can replace these two projective measurements only by special error-free generalized energy measurements with pairs of tailored, protocol-dependent post-measurement states that satisfy detailed balance-like relations. For other generalized measurements, the Crooks relation is typically not satisfied. For the validity of the Jarzynski equality, it is sufficient that the first energy measurements are error-free and the post-measurement states form a complete orthonormal set of elements in the Hilbert space of the considered system. Additionally, the effects of the second energy measurements must have unit trace. We illustrate our results by an example of a two-level system for different generalized measurements.
Transient quantum fluctuation theorems and generalized measurements
NASA Astrophysics Data System (ADS)
Prasanna Venkatesh, B.; Watanabe, Gentaro; Talkner, Peter
2014-05-01
The transient quantum fluctuation theorems of Crooks and Jarzynski restrict and relate the statistics of work performed in forward and backward forcing protocols. So far, these theorems have been obtained under the assumption that the work is determined by two projective energy measurements, one at the end, and the other one at the beginning of each run of the protocol.We found that one can replace these two projective measurements only by special error-free generalized energy measurements with pairs of tailored, protocol-dependent post-measurement states that satisfy detailed balance-like relations. For other generalized measurements, the Crooks relation is typically not satisfied. For the validity of the Jarzynski equality, it is sufficient that the first energy measurements are error-free and the post-measurement states form a complete orthonormal set of elements in the Hilbert space of the considered system. Additionally, the effects of the second energy measurements must have unit trace. We illustrate our results by an example of a two-level system for different generalized measurements.
Ethanol wet-bonding technique sensitivity assessed by AFM.
Osorio, E; Toledano, M; Aguilera, F S; Tay, F R; Osorio, R
2010-11-01
In ethanol wet bonding, water is replaced by ethanol to maintain dehydrated collagen matrices in an extended state to facilitate resin infiltration. Since short ethanol dehydration protocols may be ineffective, this study tested the null hypothesis that there are no differences in ethanol dehydration protocols for maintaining the surface roughness, fibril diameter, and interfibrillar spaces of acid-etched dentin. Polished human dentin surfaces were etched with phosphoric acid and water-rinsed. Tested protocols were: (1) water-rinse (control); (2) 100% ethanol-rinse (1-min); (3) 100% ethanol-rinse (5-min); and (4) progressive ethanol replacement (50-100%). Surface roughness, fibril diameter, and interfibrillar spaces were determined with atomic force microscopy and analyzed by one-way analysis of variance and the Student-Newman-Keuls test (α = 0.05). Dentin roughness and fibril diameter significantly decreased when 100% ethanol (1-5 min) was used for rinsing (p < 0.001). Absolute ethanol produced collapse and shrinkage of collagen fibrils. Ascending ethanol concentrations did not collapse the matrix and shrank the fibrils less than absolute ethanol-rinses.
Pullara, Filippo; Guerrero-Santoro, Jennifer; Calero, Monica; Zhang, Qiangmin; Peng, Ye; Spåhr, Henrik; Kornberg, Guy L.; Cusimano, Antonella; Stevenson, Hilary P.; Santamaria-Suarez, Hugo; Reynolds, Shelley L.; Brown, Ian S.; Monga, Satdarshan P.S.; Van Houten, Bennett; Rapić-Otrin, Vesna; Calero, Guillermo; Levine, Arthur S.
2014-01-01
Expression of recombinant proteins in bacterial or eukaryotic systems often results in aggregation rendering them unavailable for biochemical or structural studies. Protein aggregation is a costly problem for biomedical research. It forces research laboratories and the biomedical industry to search for alternative, more soluble, non-human proteins and limits the number of potential “druggable” targets. In this study we present a highly reproducible protocol that introduces the systematic use of an extensive number of detergents to solubilize aggregated proteins expressed in bacterial and eukaryotic systems. We validate the usefulness of this protocol by solubilizing traditionally difficult human protein targets to milligram quantities and confirm their biological activity. We use this method to solubilize monomeric or multimeric components of multi-protein complexes and demonstrate its efficacy to reconstitute large cellular machines. This protocol works equally well on cytosolic, nuclear and membrane proteins and can be easily adapted to a high throughput format. PMID:23137940
A Mechanism for Reliable Mobility Management for Internet of Things Using CoAP
Chun, Seung-Man; Park, Jong-Tae
2017-01-01
Under unreliable constrained wireless networks for Internet of Things (IoT) environments, the loss of the signaling message may frequently occur. Mobile Internet Protocol version 6 (MIPv6) and its variants do not consider this situation. Consequently, as a constrained device moves around different wireless networks, its Internet Protocol (IP) connectivity may be frequently disrupted and power can be drained rapidly. This can result in the loss of important sensing data or a large delay for time-critical IoT services such as healthcare monitoring and disaster management. This paper presents a reliable mobility management mechanism in Internet of Things environments with lossy low-power constrained device and network characteristics. The idea is to use the Internet Engineering Task Force (IETF) Constrained Application Protocol (CoAP) retransmission mechanism to achieve both reliability and simplicity for reliable IoT mobility management. Detailed architecture, algorithms, and message extensions for reliable mobility management are presented. Finally, performance is evaluated using both mathematical analysis and simulation. PMID:28085109
A Mechanism for Reliable Mobility Management for Internet of Things Using CoAP.
Chun, Seung-Man; Park, Jong-Tae
2017-01-12
Under unreliable constrained wireless networks for Internet of Things (IoT) environments, the loss of the signaling message may frequently occur. Mobile Internet Protocol version 6 (MIPv6) and its variants do not consider this situation. Consequently, as a constrained device moves around different wireless networks, its Internet Protocol (IP) connectivity may be frequently disrupted and power can be drained rapidly. This can result in the loss of important sensing data or a large delay for time-critical IoT services such as healthcare monitoring and disaster management. This paper presents a reliable mobility management mechanism in Internet of Things environments with lossy low-power constrained device and network characteristics. The idea is to use the Internet Engineering Task Force (IETF) Constrained Application Protocol (CoAP) retransmission mechanism to achieve both reliability and simplicity for reliable IoT mobility management. Detailed architecture, algorithms, and message extensions for reliable mobility management are presented. Finally, performance is evaluated using both mathematical analysis and simulation.
Comparison of gradual and rapid onset runs in a short-arm centrifugation
NASA Astrophysics Data System (ADS)
Miyamoto, A.; Saga, K.; Kinoue, T.; Nakazato, T.; Hirayanagi, K.; Yajima, K.; Hayashi, S.; Matsumoto, S.
A gradual onset run (GOR) in a short-arm centrifugation was performed on ten healthy students. The centrifuge had a 1.8 m radius, and the subjects sat on a chair in a cabin. The Gz force increased to 2.2 Gz at 0.1 °/sec 2 for 32 min. and the same Gz-level was maintained for 20 min. Three out of ten subjects completed the whole protocol; the load on the others was terminated because of symptoms or increased heart rate. There were few symptoms such as vertigo, that was a common problem with a rapid onset run (ROR) in former experiments, due to the short-arm centrifugation. The changes of the flicker test after the load were much less in the GOR protocol than in the ROR protocol, even in the terminated group. GOR seemed preferable to ROR in preventing vertigo even though it took longer to reach the necessary G load.
Sikiric, P; Separovic, J; Buljat, G; Anic, T; Stancic-Rokotov, D; Mikus, D; Marovic, A; Prkacin, I; Duplancic, B; Zoricic, I; Aralica, G; Lovric-Bencic, M; Ziger, T; Perovic, D; Rotkvic, I; Mise, S; Hanzevacki, M; Hahn, V; Seiwerth, S; Turkovic, B; Grabarevic, Z; Petek, M; Rucman, R
2000-01-01
Various antidepressants have antiulcer activity. Likewise, the models currently used in ulcers and depression disorders research have a considerable degree of similarity. Therefore, the possibility that depression disorders could be effectively influenced by a primary antiulcer agent with a cyto/organoprotective activity, such as the novel stomach pentadecapeptide BPC 157, was investigated in two rat depression assays. First, a forced swimming test (a Porsolt's procedure) was used. As a more severe procedure, chronic unpredictable stress (after 5 d of unpredictable stress protocol, once daily drug application during stress procedure, open field-immobility test assessment at fourth or sixth day of medication) was used. In a forced swimming test, a reduction of the immobility time in BPC 157 (10 microg, 10 ng x kg(-1) i.p.) treated rats corresponds to the activity of the 15 mg or 40 mg (i.p.) of conventional antidepressants, imipramine or nialamide, respectively, given according to the original Porsolt's protocol. In chronic unpredictable stress procedure, particular aggravation of experimental conditions markedly affected the conventional antidepressant activity, whereas BPC 157 effectiveness was continuously present. The effect of daily imipramine (30 mg) medication could be seen only after a more prolonged period, but not after a shorter period (i.e., 4-d protocol). In these conditions, no delay in the effectiveness was noted in BPC 157 medication and a reduction of the immobility of chronically stressed rats was noted after both 4 and 6 d of BPC 157 (10 microg, 10 ng) medication.
Improving Pressure Ulcer Reconstruction: Our Protocol and the COP (Cone of Pressure) Flap
Edstrom, Lee; Szymanski, Karen; Schmidt, Scott; Bevivino, Jack; Zienowicz, Richard; Stark, Jennifer; Taylor, Helena O.; Podda, Silvio; Liu, Paul
2017-01-01
Background: Surgical treatment of pressure ulcers is challenging for high recurrence rates. Deepithelialized flaps have been used previously with the aim to eliminate shearing forces and the cone of pressure (COP) effect. The goal of this study is to adopt a standardized protocol and evaluate if 2 different flap techniques affect outcomes. Methods: The novel COP flap is illustrated. Twenty patients were prospectively treated with flap coverage over a 36-month period. According to the flap type, patients were assigned to 2 groups: group 1 with 11 patients treated with the COP flap and group 2 with 9 patients treated with conventional flap without anchoring technique. We adopted a standardized protocol of debridement, tissue cultures, and negative-pressure wound therapy. Rotation fasciocutaneous flaps were used for both groups and mean follow-up was 19 months. The COP flap is a large deepithelialized rotation flap inset with transcutaneous nonabsorbable bolster sutures. The 2 groups were comparable for demographics and ulcer location and size (P < 0.05). Five patients showed positive cultures and were treated with antibiotics and negative-pressure therapy before surgery. Results: Recurrence rates were 12% in the COP flap group and 60% in the conventional flap coverage group (P < 0.001). Results were compared at 16-month follow-up. Conclusions: The COP flap significantly reduces recurrences and eliminates shearing forces, suture ripping, and tension on superficial soft-tissue layers. The technique can be applied to both ischial and sacral pressure sores. The flap provides padding over bony prominence without jeopardizing flap vascularity. PMID:28458961
Development of wide area environment accelerator operation and diagnostics method
NASA Astrophysics Data System (ADS)
Uchiyama, Akito; Furukawa, Kazuro
2015-08-01
Remote operation and diagnostic systems for particle accelerators have been developed for beam operation and maintenance in various situations. Even though fully remote experiments are not necessary, the remote diagnosis and maintenance of the accelerator is required. Considering remote-operation operator interfaces (OPIs), the use of standard protocols such as the hypertext transfer protocol (HTTP) is advantageous, because system-dependent protocols are unnecessary between the remote client and the on-site server. Here, we have developed a client system based on WebSocket, which is a new protocol provided by the Internet Engineering Task Force for Web-based systems, as a next-generation Web-based OPI using the Experimental Physics and Industrial Control System Channel Access protocol. As a result of this implementation, WebSocket-based client systems have become available for remote operation. Also, as regards practical application, the remote operation of an accelerator via a wide area network (WAN) faces a number of challenges, e.g., the accelerator has both experimental device and radiation generator characteristics. Any error in remote control system operation could result in an immediate breakdown. Therefore, we propose the implementation of an operator intervention system for remote accelerator diagnostics and support that can obviate any differences between the local control room and remote locations. Here, remote-operation Web-based OPIs, which resolve security issues, are developed.
Pedata, Paola; Corvino, Anna Rita; Napolitano, Raffaele Carmine; Garzillo, Elpidio Maria; Furfaro, Ciro; Lamberti, Monica
2016-01-20
From many years now, thanks to the development of modern diving techniques, there has been a rapid spread of diving activities everywhere. In fact, divers are ever more numerous both among the Armed Forces and civilians who dive for work, like fishing, biological research and archeology. The aim of the study was to propose a health protocol for work fitness of professional divers keeping in mind the peculiar work activity, existing Italian legislation that is almost out of date and the technical and scientific evolution in this occupational field. We performed an analysis of the most frequently occurring diseases among professional divers and of the clinical investigation and imaging techniques used for work fitness assessment of professional divers. From analysis of the health protocol recommended by D.M. 13 January 1979 (Ministerial Decree), that is most used by occupational health physician, several critical issues emerged. Very often the clinical investigation and imaging techniques still used are almost obsolete, ignoring the execution of simple and inexpensive investigations that are more useful for work fitness assessment. Considering the out-dated legislation concerning diving disciplines, it is necessary to draw up a common health protocol that takes into account clinical and scientific knowledge and skills acquired in this area. This protocol's aim is to propose a useful tool for occupational health physicians who work in this sector.
Federici, Stefano; Stefano, Federici; Borsci, Simone; Stamerra, Gianluca
2010-08-01
A verbal protocol technique, adopted for a web usability evaluation, requires that the users are able to perform a double task: surfing and talking. Nevertheless, when blind users surf by using a screen reader and talk about the way they interact with the computer, the evaluation is influenced by a structural interference: users are forced to think aloud and listen to the screen reader at the same time. The aim of this study is to build up a verbal protocol technique for samples of visual impaired users in order to overcome the limits of concurrent and retrospective protocols. The technique we improved, called partial concurrent thinking aloud (PCTA), integrates a modified set of concurrent verbalization and retrospective analysis. One group of 6 blind users and another group of 6 sighted users evaluated the usability of a website using PCTA. By estimating the number of necessary users by the means of an asymptotic test, it was found out that the two groups had an equivalent ability of identifying usability problems, both over 80%. The result suggests that PCTA, while respecting the properties of classic verbal protocols, also allows to overcome the structural interference and the limits of concurrent and retrospective protocols when used with screen reader users. In this way, PCTA reduces the efficiency difference of usability evaluation between blind and sighted users.
Jang, Andrew T.; Lin, Jeremy D.; Seo, Youngho; Etchin, Sergey; Merkle, Arno; Fahey, Kevin; Ho, Sunita P.
2014-01-01
This study demonstrates a novel biomechanics testing protocol. The advantage of this protocol includes the use of an in situ loading device coupled to a high resolution X-ray microscope, thus enabling visualization of internal structural elements under simulated physiological loads and wet conditions. Experimental specimens will include intact bone-periodontal ligament (PDL)-tooth fibrous joints. Results will illustrate three important features of the protocol as they can be applied to organ level biomechanics: 1) reactionary force vs. displacement: tooth displacement within the alveolar socket and its reactionary response to loading, 2) three-dimensional (3D) spatial configuration and morphometrics: geometric relationship of the tooth with the alveolar socket, and 3) changes in readouts 1 and 2 due to a change in loading axis, i.e. from concentric to eccentric loads. Efficacy of the proposed protocol will be evaluated by coupling mechanical testing readouts to 3D morphometrics and overall biomechanics of the joint. In addition, this technique will emphasize on the need to equilibrate experimental conditions, specifically reactionary loads prior to acquiring tomograms of fibrous joints. It should be noted that the proposed protocol is limited to testing specimens under ex vivo conditions, and that use of contrast agents to visualize soft tissue mechanical response could lead to erroneous conclusions about tissue and organ-level biomechanics. PMID:24638035
Calibration and energy measurement of optically levitated nanoparticle sensors
NASA Astrophysics Data System (ADS)
Hebestreit, Erik; Frimmer, Martin; Reimann, René; Dellago, Christoph; Ricci, Francesco; Novotny, Lukas
2018-03-01
Optically levitated nanoparticles offer enormous potential for precision sensing. However, as for any other metrology device, the absolute measurement performance of a levitated-particle sensor is limited by the accuracy of the calibration relating the measured signal to an absolute displacement of the particle. Here, we suggest and demonstrate calibration protocols for levitated-nanoparticle sensors. Our calibration procedures include the treatment of anharmonicities in the trapping potential, as well as a protocol using a harmonic driving force, which is applicable if the sensor is coupled to a heat bath of unknown temperature. Finally, using the calibration, we determine the center-of-mass temperature of an optically levitated particle in thermal equilibrium from its motion and discuss the optimal measurement time required to determine the said temperature.
Dias, Janice; Diakonis, Vasilios F.; Lorenzo, Michael; Gonzalez, Felipe; Porras, Kevin; Douglas, Simone; Avila, Marcel; Yoo, Sonia H.; Ziebarth, Noël M.
2015-01-01
The purpose of this study was to evaluate elasticity and viscoelasticity in the anterior and deeper stromal regions of the cornea after cross linking with three different protocols using atomic force microscopy (AFM) through indentation. A total of 40 porcine corneas were used in this study and were divided into 4 groups (10 corneas per group): control (no treatment), Dresden (corneal epithelial debridement, riboflavin pretreatment for 30 minutes and a 3mw/cm2 for 30 minutes UVA irradiation), accelerated (corneal epithelial debridement, riboflavin pretreatment for 30 minutes and a 30mw/cm2 for 3 minutes UVA irradiation), and genipin (corneal epithelial debridement and submersion of anterior surface in a 1% genipin solution for 4 hours). Elasticity and viscoelasticity were quantified using AFM through indentation for all corneas, for the anterior stroma and at a depth of 200μm. For the control, Dresden, accelerated, and Genipin groups, respectively, the average Young’s modulus for the anterior stromal region was 0.60±0.58MPa, 1.58 ±1.04MPa, 0.86±0.46MPa, and 1.71±0.51MPa; the average for the 200μm stromal depth was 0.08±0.06MPa, 0.08±0.04MPa, 0.08±0.04MPa, and 0.06±0.01MPa. Corneas crosslinked with the Dresden protocol and genipin were significantly stiffer than controls (p<0.05) in the anterior region only. For the control, Dresden, Accelerated, and Genipin groups, respectively, the average calculated apparent viscosity for the anterior stroma was 88.2±43.7kPa-s, 8.3±7.1kPa-s, 8.1±2.3kPa-s, and 9.5±3.8kPa-s; the average for the 200μm stromal depth was 35.0±3.7kPa-s, 49.6±35.1kPa-s, 42.4±17.6kPa-s, and 41.8±37.6kPa-s. All crosslinking protocols resulted in a decrease in viscosity in the anterior region only (p<0.05). The effects of cross-linking seem to be limited to the anterior corneal stroma and do not extend to the deeper stromal region. Additionally, the Dresden and genipin protocols seem to produce a stiffer anterior corneal stroma when compared to the accelerated protocol. PMID:26093276
Refinement of NMR structures using implicit solvent and advanced sampling techniques.
Chen, Jianhan; Im, Wonpil; Brooks, Charles L
2004-12-15
NMR biomolecular structure calculations exploit simulated annealing methods for conformational sampling and require a relatively high level of redundancy in the experimental restraints to determine quality three-dimensional structures. Recent advances in generalized Born (GB) implicit solvent models should make it possible to combine information from both experimental measurements and accurate empirical force fields to improve the quality of NMR-derived structures. In this paper, we study the influence of implicit solvent on the refinement of protein NMR structures and identify an optimal protocol of utilizing these improved force fields. To do so, we carry out structure refinement experiments for model proteins with published NMR structures using full NMR restraints and subsets of them. We also investigate the application of advanced sampling techniques to NMR structure refinement. Similar to the observations of Xia et al. (J.Biomol. NMR 2002, 22, 317-331), we find that the impact of implicit solvent is rather small when there is a sufficient number of experimental restraints (such as in the final stage of NMR structure determination), whether implicit solvent is used throughout the calculation or only in the final refinement step. The application of advanced sampling techniques also seems to have minimal impact in this case. However, when the experimental data are limited, we demonstrate that refinement with implicit solvent can substantially improve the quality of the structures. In particular, when combined with an advanced sampling technique, the replica exchange (REX) method, near-native structures can be rapidly moved toward the native basin. The REX method provides both enhanced sampling and automatic selection of the most native-like (lowest energy) structures. An optimal protocol based on our studies first generates an ensemble of initial structures that maximally satisfy the available experimental data with conventional NMR software using a simplified force field and then refines these structures with implicit solvent using the REX method. We systematically examine the reliability and efficacy of this protocol using four proteins of various sizes ranging from the 56-residue B1 domain of Streptococcal protein G to the 370-residue Maltose-binding protein. Significant improvement in the structures was observed in all cases when refinement was based on low-redundancy restraint data. The proposed protocol is anticipated to be particularly useful in early stages of NMR structure determination where a reliable estimate of the native fold from limited data can significantly expedite the overall process. This refinement procedure is also expected to be useful when redundant experimental data are not readily available, such as for large multidomain biomolecules and in solid-state NMR structure determination.
Atomic force microscopy and spectroscopy to probe single membrane proteins in lipid bilayers.
Sapra, K Tanuj
2013-01-01
The atomic force microscope (AFM) has opened vast avenues hitherto inaccessible to the biological scientist. The high temporal (millisecond) and spatial (nanometer) resolutions of the AFM are suited for studying many biological processes in their native conditions. The AFM cantilever stylus is aptly termed as a "lab on a tip" owing to its versatility as an imaging tool as well as a handle to manipulate single bonds and proteins. Recent examples assert that the AFM can be used to study the mechanical properties and monitor processes of single proteins and single cells, thus affording insight into important mechanistic details. This chapter specifically focuses on practical and analytical protocols of single-molecule AFM methodologies related to high-resolution imaging and single-molecule force spectroscopy of membrane proteins. Both these techniques are operator oriented, and require specialized working knowledge of the instrument, theoretical, and practical skills.
Reliability of the individual components of the Canadian Armed Forces Physical Employment Standard.
Stockbrugger, Barry G; Reilly, Tara J; Blacklock, Rachel E; Gagnon, Patrick J
2018-01-29
This investigation recruited 24 participants from both the Canadian Armed Forces (CAF) and civilian populations to complete 4 separate trials at "best effort" of each of the 4 components in the CAF Physical Employment Standard named the FORCE Evaluation: Fitness for Operational Requirements of CAF Employment. Analyses were performed to examine the level of variability and reliability within each component. The results demonstrate that candidates should be provided with at least 1 retest if they have recently completed at least 2 previous best effort attempts as per the protocol. In addition, the minimal detectable difference is given for each of the 4 components in seconds which identifies the threshold for subsequent action, either retest or remedial training, for those unable to meet the minimum standard. These results will educate the delivery of this employment standard, function as a method of accommodation, in addition to providing direction for physical training programs.
Wasinski, Frederick; Estrela, Gabriel R.; Arakaki, Aline M.; Bader, Michael; Alenina, Natalia; Klempin, Friederike; Araújo, Ronaldo C.
2016-01-01
Physical exercise positively affects the metabolism and induces proliferation of precursor cells in the adult brain. Maternal exercise likewise provokes adaptations early in the offspring. Using a high-intensity swimming protocol that comprises forced swim training before and during pregnancy, we determined the effect of maternal swimming on the mouse offspring's neurogenesis. Our data demonstrate decreased proliferation in sublayers of the postnatal dentate gyrus in offspring of swimming mother at postnatal day (P) 8 accompanied with decreased survival of newly generated cells 4 weeks later. The reduction in cell numbers was predominantly seen in the hilus and molecular layer. At P35, the reduced amount of cells was also reflected by a decrease in the population of newly generated immature and mature neurons of the granule cell layer. Our data suggest that forced maternal swimming at high-intensity has a negative effect on the neurogenic niche development in postnatal offspring. PMID:27621701
Neme, A L; Frazier, K B; Roeder, L B; Debner, T L
2002-01-01
Many polishing protocols have been evaluated in vitro for their effect on the surface roughness of restorative materials. These results have been useful in establishing protocols for in vivo application. However, limited research has focused on the subsequent care and maintenance of esthetic restorations following their placement. This investigation evaluated the effect of five polishing protocols that could be implemented at recall on the surface roughness of five direct esthetic restorative materials. Specimens (n=25) measuring 8 mm diameter x 3 mm thick were fabricated in an acrylic mold using five light-cured resin-based materials (hybrid composite, microfilled composite, packable composite, compomer and resin-modified glass ionomer). After photopolymerization, all specimens were polished with Sof-Lex Disks to produce an initial (baseline) surface finish. All specimens were then polished with one of five prophylactic protocols (Butler medium paste, Butler coarse paste, OneGloss, SuperBuff or OneGloss & SuperBuff). The average surface roughness of each treated specimen was determined from three measurements with a profilometer (Surface 1). Next, all specimens were brushed 60,000 times at 1.5 Hz using a brush-head force of 2 N on a Manly V-8 cross-brushing machine in a 50:50 (w/w) slurry of toothpaste and water. The surface roughness of each specimen was measured after brushing (Surface 2) followed by re-polishing with one of five protocols, then final surface roughness values were determined (Surface 3). The data were analyzed using repeated measures ANOVA. Significant differences (p=0.05) in surface roughness were observed among restorative materials and polishing protocols. The microfilled and hybrid resin composite yielded significantly rougher surfaces than the other three materials following tooth brushing. Prophylactic polishing protocols can be used to restore a smooth surface on resin-based esthetic restorative materials following simulated tooth brushing.
Screening Protocol for the Electrochemical Characterization of Potential Supercapacitor Materials
2009-11-01
Felix Wong; DRDC Atlantic TM 2009-279; R & D pour la défense Canada – Atlantique; Novembre 2009. Introduction ou contexte : Les forces armées ont... 13 Figure 10: The effect of active material... 13 : Typical Constant Current Charge-Discharge Curve for a 1.34 mg Electrode of PAni-2NSA/MWNT at a Constant Current of 0.2 mA
ERIC Educational Resources Information Center
Zito-Nash, Judith A.
2017-01-01
When four forces create shift in the landscape of PK-12 education, change in response to the environment is inevitable and necessary. It is such in the United States, as schools face increased accountability for the growth and attainment of reading skills, rigorous demands of the Common Core State Standards, a rapidly growing population of…
ATTACK WARNING: Better Management Required to Resolve NORAD Integration Deficiencies
1989-07-01
protocols, Cumbersome Integration different manufacturers’ computer systems can communicate with eachother . The warning and assessment subsystems...by treating TW/AA system as a single system subject to program review and oversight by the Defense Acquisition Board. Within this management...restore the unit to operation quickly enough after a power loss to meet NORAD mis- sion requirements. The Air Force intends to have the contractor
Micropatterning on micropost arrays.
Sniadecki, Nathan J; Han, Sangyoon J; Ting, Lucas H; Feghhi, Shirin
2014-01-01
Micropatterning of cells can be used in combination with microposts to control cell shape or cell-to-cell interaction while measuring cellular forces. The protocols in this chapter describe how to make SU8 masters for stamps and microposts, how to use soft lithography to replicate these structures in polydimethylsiloxane, and how to functionalize the surface of the microposts for cell attachment. Copyright © 2014 Elsevier Inc. All rights reserved.
Robotic Laser Coating Removal System
2008-07-01
Materiel Command IRR Internal Rate of Return JTP Joint Test Protocol JTR Joint Test Report LARPS Large Area Robotic Paint Stripping LASER Light...use of laser paint stripping systems is applicable to depainting activities on large off-aircraft components and weapons systems for the Air Force...The use of laser paint stripping systems is applicable to depainting activities on large off-aircraft components and weapons systems for the Air
Identity Management Task Force Report 2008
2008-01-01
Telecommunication Grid ( GTG ) consists of the public- switched telecommunications network (PSTN), various forms of Internet protocol (IP) networks...to network providers) to a large community of nomadic users and access devices over a wide range of access technologies. The GTG is notional, and...DOC Dr. Myra Gray , DOD Greg Hall, DNI Celia Hanley, DOD Patrick Hannon, DNI James Hass, IC Linda Hill, SSA Bobby Jones, DOC Patrick Hannon
It is Time the United States Air Force Changes the way it Feeds its Airmen
2008-03-01
narrative , phenomenology , ethnography , case study , and grounded theory . In purpose, these strategies are...methodology) the research will be analyzed. Methodology A qualitative research methodology and specifically a case study strategy for the...well as theory building in chapter five . Finally, in regards to reliability, Yin’s (2003) case study protocol guidance was used as a means to
Portable Language-Independent Adaptive Translation from OCR. Phase 1
2009-04-01
including brute-force k-Nearest Neighbors ( kNN ), fast approximate kNN using hashed k-d trees, classification and regression trees, and locality...achieved by refinements in ground-truthing protocols. Recent algorithmic improvements to our approximate kNN classifier using hashed k-D trees allows...recent years discriminative training has been shown to outperform phonetic HMMs estimated using ML for speech recognition. Standard ML estimation
Haapala, Stephenie A; Faghri, Pouran D; Adams, Douglas J
2008-04-26
The purpose of this study was to investigate the biomechanics of the hip, knee and ankle during a progressive resistance cycling protocol in an effort to detect and measure the presence of muscle fatigue. It was hypothesized that knee power output can be used as an indicator of fatigue in order to assess the cycling performance of SCI subjects. Six spinal cord injured subjects (2 incomplete, 4 complete) between the ages of twenty and fifty years old and possessing either a complete or incomplete spinal cord injury at or below the fourth cervical vertebra participated in this study. Kinematic data and pedal forces were recorded during cycling at increasing levels of resistance. Ankle, knee and hip power outputs and resultant pedal force were calculated. Ergometer cadence and muscle stimulation intensity were also recorded. The main findings of this study were: (a) ankle and knee power outputs decreased, whereas hip power output increased with increasing resistance, (b) cadence, stimulation intensity and resultant pedal force in that combined order were significant predictors of knee power output and (c) knowing the value of these combined predictors at 10 rpm, an index of fatigue can be developed, quantitatively expressing the power capacity of the knee joint with respect to a baseline power level defined as fatigue. An index of fatigue was successfully developed, proportionalizing knee power capacity during cycling to a predetermined value of fatigue. The fatigue index value at 0/8th kp, measured 90 seconds into active, unassisted pedaling was 1.6. This indicates initial power capacity at the knee to be 1.6 times greater than fatigue. The fatigue index decreased to 1.1 at 2/8th kp, representing approximately a 30% decrease in the knee's power capacity within a 4 minute timespan. These findings suggest that the present cycling protocol is not sufficient for a rider to gain the benefits of FES and thus raises speculation as to whether or not progressive resistance cycling is an appropriate protocol for SCI subjects.
Haapala, Stephenie A; Faghri, Pouran D; Adams, Douglas J
2008-01-01
Background The purpose of this study was to investigate the biomechanics of the hip, knee and ankle during a progressive resistance cycling protocol in an effort to detect and measure the presence of muscle fatigue. It was hypothesized that knee power output can be used as an indicator of fatigue in order to assess the cycling performance of SCI subjects. Methods Six spinal cord injured subjects (2 incomplete, 4 complete) between the ages of twenty and fifty years old and possessing either a complete or incomplete spinal cord injury at or below the fourth cervical vertebra participated in this study. Kinematic data and pedal forces were recorded during cycling at increasing levels of resistance. Ankle, knee and hip power outputs and resultant pedal force were calculated. Ergometer cadence and muscle stimulation intensity were also recorded. Results The main findings of this study were: (a) ankle and knee power outputs decreased, whereas hip power output increased with increasing resistance, (b) cadence, stimulation intensity and resultant pedal force in that combined order were significant predictors of knee power output and (c) knowing the value of these combined predictors at 10 rpm, an index of fatigue can be developed, quantitatively expressing the power capacity of the knee joint with respect to a baseline power level defined as fatigue. Conclusion An index of fatigue was successfully developed, proportionalizing knee power capacity during cycling to a predetermined value of fatigue. The fatigue index value at 0/8th kp, measured 90 seconds into active, unassisted pedaling was 1.6. This indicates initial power capacity at the knee to be 1.6 times greater than fatigue. The fatigue index decreased to 1.1 at 2/8th kp, representing approximately a 30% decrease in the knee's power capacity within a 4 minute timespan. These findings suggest that the present cycling protocol is not sufficient for a rider to gain the benefits of FES and thus raises speculation as to whether or not progressive resistance cycling is an appropriate protocol for SCI subjects. PMID:18439300
Brady, Mark F.; Bradley, Michael P.; Fleming, Braden C.; Fadale, Paul D.; Hulstyn, Michael J.; Banerjee, Rahul
2007-01-01
Background The initial tension applied to an ACL graft at the time of fixation modulates knee motion and the tibiofemoral compressive loads. Purpose To establish the relationships between initial graft tension, tibiofemoral compressive force, and the neutral tibiofemoral position in the cadaver knee. Study Design Controlled Laboratory Study. Methods The tibiofemoral compressive forces and joint positions were determined in the ACL-intact knee at 0°, 20° and 90° knee flexion. The ACL was excised and reconstructed with a patellar tendon graft using graft tensions of 1, 15, 30, 60 and 90 N applied at 0°, 20° and 90° knee flexion. The compressive forces and neutral positions were compared between initial tension conditions and the ACL-intact knee. Results Increasing initial graft tension increased the tibiofemoral compressive forces. The forces in the medial compartment were 1.8 times those in the lateral compartment. The compressive forces were dependent on the knee angle at which the tension was applied. The greatest compressive forces occurred when the graft was tensioned with the knee in extension. An increase in initial graft tension caused the tibia to rotate externally compared to the ACL-intact knee. Increases in initial graft tension also caused a significant posterior translation of the tibia relative to the femur. Conclusions Different initial graft tension protocols produced predictable changes in the tibiofemoral compressive forces and joint positions. Clinical Relevance The tibiofemoral compressive force and neutral joint position were best replicated with a low graft tension (1–15 N) when using a patellar tendon graft. PMID:17218659
Skeletal muscle strength and endurance are maintained during moderate dehydration.
Périard, J D; Tammam, A H; Thompson, M W
2012-08-01
This study investigated the effects of moderate dehydration (~2.5% body weight) on muscle strength and endurance using percutaneous electrical stimulation to quantify central and peripheral fatigue, and isolate the combined effects of exercise-heat stress and dehydration, vs. the effect of dehydration alone. Force production and voluntary activation were calculated in 10 males during 1 brief and 15 repeated maximal voluntary isometric contractions performed prior to (control) walking in the heat (35°C), immediately following exercise, and the next morning (dehydration). The protocol was also performed in a euhydrated state. During the brief contractions, force production and voluntary activation were maintained in all trials. In contrast, force production decreased throughout the repeated contractions, regardless of hydration status (P<0.001). The decline in force was greater immediately following exercise-heat stress dehydration compared with control and euhydration (P<0.001). When dehydration was isolated from acute post-exercise dehydration, force production was maintained similarly to control and euhydration. Despite the progressive decline in force production and the increased fatigability observed during the repeated contractions, voluntary activation remained elevated throughout each muscle function test. Therefore, moderate dehydration, isolated from acute exercise-heat stress, does not appear to influence strength during a single contraction or enhance fatigability. © Georg Thieme Verlag KG Stuttgart · New York.
Jannig, Paulo R; Alves, Christiano R R; Voltarelli, Vanessa A; Bozi, Luiz H M; Vieira, Janaina S; Brum, Patricia C; Bechara, Luiz R G
2017-12-15
The current study tested the hypotheses that 1) an acute bout of aerobic exercise impairs isolated skeletal muscle contractile properties and 2) N-acetylcysteine (a thiol antioxidant; NAC) administration can restore the impaired muscle contractility after exercise. At rest or immediately after an acute bout of aerobic exercise, extensor digitorum longus (EDL) and soleus muscles from male Wistar rats were harvested for ex vivo skeletal muscle contraction experiments. Muscles from exercised animals were incubated in Krebs Ringer's buffer in absence or presence of 20mM of NAC. Force capacity and fatigue properties were evaluated. Exercised EDL and soleus displayed lower force production across various stimulation frequencies (p<0.001), indicating that skeletal muscle force production was impaired after an acute bout of exercise. However, NAC treatment restored the loss of force production in both EDL and soleus after fatiguing exercise (p<0.05). Additionally, NAC treatment increased relative force production at different time points during a fatigue-induced protocol, suggesting that NAC treatment mitigates fatigue induced by successive contractions. NAC treatment improves force capacity and fatigue properties in ex vivo skeletal muscle from rats submitted to an acute bout of aerobic exercise. Copyright © 2017 Elsevier Inc. All rights reserved.
Streptomycin and EDTA decrease the number of desmin-negative fibers following stretch injury.
Willems, Mark E T; Stauber, William T
2005-09-01
Streptomycin and ethylene diamine tetraacetic acid (EDTA) were used to examine the role of extracellular calcium in stretch-induced muscle injury. Streptomycin was injected in one group of rats, three times daily for 8 days (S, 300 mg.kg(-1).day(-1) intraperitoneally). In another group, EDTA was administered (150 mg.kg(-1) IP) 20 min before and 24 h after the injury protocol. Untreated rats (C) served as controls. Muscle injury was produced by 40 stretches of active dorsiflexor muscles by ankle rotation from 80 degrees to 130 degrees (velocity 1.75 rad.s(-1)). Ten minutes after the injury protocols, all animals lost the same amount of isometric force at both low and high stimulation frequencies (20 HZ; S, 56 +/- 6%; EDTA, 47 +/- 7%; C, 55 +/- 4%) and 120 HZ; S, 11 +/- 3%, EDTA, 13 +/- 3%; C, 11 +/- 3%). Tibialis anterior (TA) muscles were removed after 48 h for morphometric analysis. In both streptomycin-and EDTA-treated rats, the percent of injured (i.e., desmin-negative) myofibers in TA was reduced compared to untreated, injured muscles (S, 0.35 +/- 0.08%; EDTA, 0.64 +/- 0.19%; C, 1.81 +/- 0.43%). Thus, streptomycin and EDTA treatment did not alter the development of muscle weakness (i.e., isometric force deficit), but almost abolished the histopathologic changes. This study shows that the mechanisms for muscle weakness and histopathologic changes (inflammation) following repeated muscle strains can largely be dissociated from each other and helps explain why there is no correlation between isometric force deficits and the number of pathologic cells.
Salgueiro, Mônica da Consolação Canuto; Bortoletto, Carolina Carvalho; Horliana, Anna Carolina RattoTempestini; Mota, Ana Carolina Costa; Motta, Lara Jansiski; Motta, Pamella de Barros; MesquitaFerrari, Raquel Agnelli; Fernandes, Kristianne Porta Santos; Bussadori, Sandra Kalil
2017-08-08
Bruxism is a repetitive activity that causes tooth wear, audible sounds, and discomfort. Preventive measures have been studied for conditions that can exert a negative influence on physiological development in children. Low-level laser therapy administered over acupoints is an effective, painless, low-cost treatment option that has achieved good results. Thus, the aim of the proposed study is to evaluate changes in muscle activity, bite force and salivary cortisol in children with bruxism after the application of low-level laser to accupoints. The children will be randomly allocated to four groups of 19 individuals: G1 - low-level laser; G2 - occlusal splint; G3 - placebo laser; and G4 - control (without bruxism). The BTS TMJOINT electromyography will be used to determine muscle activity and a digital gnathodynamometer will be used to measure bite force. Salivary cortisol will be analysed at baseline as well as one and six months after treatment. Two-way ANOVA will be employed and complemented by Tukey's test. Bruxism is a repetitive activity of the masticatory muscles that can have negative consequences if not treated, such as tooth wear, noises, discomfort and anxiety. Thus, control and treatment measures should be taken. Although low-level laser therapy over acupoints has been indicated for children, the effects of this treatment modality have not yet been studied. NCT02757261 on 8 April 2016. This study protocol received a grant from the Brazilian fostering agency São Paulo Research Foundation (FAPESP: #2015/24731-0).
McQuade, Kevin; Price, Robert; Liu, Nelson; Ciol, Marcia A
2012-08-30
Examination of articular joints is largely based on subjective assessment of the "end-feel" of the joint in response to manually applied forces at different joint orientations. This technical report aims to describe the development of an objective method to examine joints in general, with specific application to the shoulder, and suitable for clinical use. We adapted existing hardware and developed laptop-based software to objectively record the force/displacement behavior of the glenohumeral joint during three common manual joint examination tests with the arm in six positions. An electromagnetic tracking system recorded three-dimensional positions of sensors attached to a clinician examiner and a patient. A hand-held force transducer recorded manually applied translational forces. The force and joint displacement were time-synchronized and the joint stiffness was calculated as a quantitative representation of the joint "end-feel." A methodology and specific system checks were developed to enhance clinical testing reproducibility and precision. The device and testing protocol were tested on 31 subjects (15 with healthy shoulders, and 16 with a variety of shoulder impairments). Results describe the stiffness responses, and demonstrate the feasibility of using the device and methods in clinical settings.
NASA Astrophysics Data System (ADS)
Good, Peter; Andrews, Timothy; Chadwick, Robin; Dufresne, Jean-Louis; Gregory, Jonathan M.; Lowe, Jason A.; Schaller, Nathalie; Shiogama, Hideo
2016-11-01
nonlinMIP provides experiments that account for state-dependent regional and global climate responses. The experiments have two main applications: (1) to focus understanding of responses to CO2 forcing on states relevant to specific policy or scientific questions (e.g. change under low-forcing scenarios, the benefits of mitigation, or from past cold climates to the present day), or (2) to understand the state dependence (non-linearity) of climate change - i.e. why doubling the forcing may not double the response. State dependence (non-linearity) of responses can be large at regional scales, with important implications for understanding mechanisms and for general circulation model (GCM) emulation techniques (e.g. energy balance models and pattern-scaling methods). However, these processes are hard to explore using traditional experiments, which explains why they have had so little attention in previous studies. Some single model studies have established novel analysis principles and some physical mechanisms. There is now a need to explore robustness and uncertainty in such mechanisms across a range of models (point 2 above), and, more broadly, to focus work on understanding the response to CO2 on climate states relevant to specific policy/science questions (point 1). nonlinMIP addresses this using a simple, small set of CO2-forced experiments that are able to separate linear and non-linear mechanisms cleanly, with a good signal-to-noise ratio - while being demonstrably traceable to realistic transient scenarios. The design builds on the CMIP5 (Coupled Model Intercomparison Project Phase 5) and CMIP6 DECK (Diagnostic, Evaluation and Characterization of Klima) protocols, and is centred around a suite of instantaneous atmospheric CO2 change experiments, with a ramp-up-ramp-down experiment to test traceability to gradual forcing scenarios. In all cases the models are intended to be used with CO2 concentrations rather than CO2 emissions as the input. The understanding gained will help interpret the spread in policy-relevant scenario projections. Here we outline the basic physical principles behind nonlinMIP, and the method of establishing traceability from abruptCO2 to gradual forcing experiments, before detailing the experimental design, and finally some analysis principles. The test of traceability from abruptCO2 to transient experiments is recommended as a standard analysis within the CMIP5 and CMIP6 DECK protocols.
Analysis of Security Protocols for Mobile Healthcare.
Wazid, Mohammad; Zeadally, Sherali; Das, Ashok Kumar; Odelu, Vanga
2016-11-01
Mobile Healthcare (mHealth) continues to improve because of significant improvements and the decreasing costs of Information Communication Technologies (ICTs). mHealth is a medical and public health practice, which is supported by mobile devices (for example, smartphones) and, patient monitoring devices (for example, various types of wearable sensors, etc.). An mHealth system enables healthcare experts and professionals to have ubiquitous access to a patient's health data along with providing any ongoing medical treatment at any time, any place, and from any device. It also helps the patient requiring continuous medical monitoring to stay in touch with the appropriate medical staff and healthcare experts remotely. Thus, mHealth has become a major driving force in improving the health of citizens today. First, we discuss the security requirements, issues and threats to the mHealth system. We then present a taxonomy of recently proposed security protocols for mHealth system based on features supported and possible attacks, computation cost and communication cost. Our detailed taxonomy demonstrates the strength and weaknesses of recently proposed security protocols for the mHealth system. Finally, we identify some of the challenges in the area of security protocols for mHealth systems that still need to be addressed in the future to enable cost-effective, secure and robust mHealth systems.
Duarte, Felipe Coutinho Kullmann; Kolberg, Carolina; Barros, Rodrigo R; Silva, Vivian G A; Gehlen, Günter; Vassoler, Jakson M; Partata, Wania A
2014-05-01
This study was designed to assess the peak force of a manually operated chiropractic adjusting instrument, the Activator Adjusting Instrument 4 (AAI 4), with an adapter for use in animals, which has a 3- to 4-fold smaller contact surface area than the original rubber tip. Peak force was determined by thrusting the AAI 4 with the adapter or the original rubber tip onto a load cell. First, the AAI 4 was applied perpendicularly by a doctor of chiropractic onto the load cell. Then, the AAI 4 was fixed in a rigid framework and applied to the load cell. This procedure was done to prevent any load on the load cell before the thrust impulse. In 2 situations, trials were performed with the AAI 4 at all force settings (settings I, II, III, and IV, minimum to maximum, respectively). A total of 50000 samples per second over a period of 3 seconds were collected. In 2 experimental protocols, the use of the adapter in the AAI 4 increased the peak force only with setting I. The new value was around 80% of the maximum value found for the AAI 4. Nevertheless, the peak force values of the AAI 4 with the adapter and with the original rubber tip in setting IV were similar. The adapter effectively determines the maximum peak force value at force setting I of AAI 4. Copyright © 2014 National University of Health Sciences. Published by Mosby, Inc. All rights reserved.
Sawada, Hiromi; Ogawa, Takuya; Kataoka, Keiichi; Baba, Yoshiyuki; Moriyama, Keiji
2017-03-01
Maxillary distraction osteogenesis (DO) is a mainstream surgical technique for patients who have severe maxillary hypoplasia associated with craniofacial syndromes and cleft-related deformities. However, limited information about the biomechanical aspects of maxillary DO is available limiting broad utilization and improvements to the procedure. The objective of this study was to analyze force levels during the active distraction process and to investigate the relationship between distraction force and maxillary movement during Le Fort I maxillary DO using a rigid external distraction (RED) system. Microtension gauges were integrated into the distraction wires on each side of the RED system. Six patients with cleft lip and palate aged 12.8 to 23.5 years underwent strain gauge measurements during maxillary advancement with DO using an RED system. Lateral cephalograms were taken to measure maxillary horizontal, vertical, and linear movements after DO. The average linear maxillary movement was 11.2 mm (range 8.5-15.9 mm). The applied forces ranged from 13.4 to 26.8 N. The distance of maxillary movement was proportional to the distraction force. The measurement of distraction forces during DO provides important information with which to establish appropriate protocols. Patients requiring more advancement may require more distraction force. However, other factors such as scarring, patient anatomy, surgical freedom of the osteotomized maxilla, and the like, may affect the required force during DO with the RED system.
Ansdell, Paul; Dekerle, Jeanne
2017-10-10
To investigate the development of neuromuscular fatigue during a basketball game simulation and ascertain whether sodium bicarbonate (NaHCO3) supplementation attenuates any neuromuscular fatigue that persists. Ten participants ingested 0.2 g.kg of NaHCO3 (or an equimolar placebo dosage of sodium chloride [NaCl]) 90 and 60 minutes prior to commencing a basketball game simulation (ALK-T vs PLA-T). Isometric maximal voluntary contractions of the knee extensors (MVIC) and potentiated high (100 Hz) and low (10 Hz) frequency doublet twitches were recorded before and after each match quarter for both trials. In addition, 15 m sprint times and layup completion (%) were recorded during each quarter. MVIC, 100 and 10 Hz twitch forces declined progressively in both trials (P<0.05) with a less pronounced decrease in MVIC during ALK-T (P<0.01). Both 100 and 10 Hz twitch forces were also significantly greater in ALK-T (P<0.05). 15 m sprint time increased over the course of both trials (∼2%, P<0.01); however, no significant condition or time effect was found for layup completion (P>0.05). A basketball simulation protocol induces a substantial amount of neuromuscular (reduction in knee extensor MVICs) and peripheral fatigue with a concomitant increase in 15 m sprint time over the protocol. NaHCO3 supplementation attenuated the rate of fatigue development by protecting contractile elements of the muscle fibres. This study provides coaches with information about the magnitude of fatigue induced by a simulated basketball game, and provides evidence of the efficacy of NaHCO3 in attenuating fatigue.
Stratis, Andreas; Zhang, Guozhi; Lopez-Rendon, Xochitl; Politis, Constantinus; Hermans, Robert; Jacobs, Reinhilde; Bogaerts, Ria; Shaheen, Eman; Bosmans, Hilde
2017-09-01
To calculate organ doses and estimate the effective dose for justification purposes in patients undergoing orthognathic treatment planning purposes and temporal bone imaging in dental cone beam CT (CBCT) and Multidetector CT (MDCT) scanners. The radiation dose to the ICRP reference male voxel phantom was calculated for dedicated orthognathic treatment planning acquisitions via Monte Carlo simulations in two dental CBCT scanners, Promax 3D Max (Planmeca, FI) and NewTom VGi evo (QR s.r.l, IT) and in Somatom Definition Flash (Siemens, DE) MDCT scanner. For temporal bone imaging, radiation doses were calculated via MC simulations for a CBCT protocol in NewTom 5G (QR s.r.l, IT) and with the use of a software tool (CT-expo) for Somatom Force (Siemens, DE). All procedures had been optimized at the acceptance tests of the devices. For orthognathic protocols, dental CBCT scanners deliver lower doses compared to MDCT scanners. The estimated effective dose (ED) was 0.32mSv for a normal resolution operation mode in Promax 3D Max, 0.27mSv in VGi-evo and 1.18mSv in the Somatom Definition Flash. For temporal bone protocols, the Somatom Force resulted in an estimated ED of 0.28mSv while for NewTom 5G the ED was 0.31 and 0.22mSv for monolateral and bilateral imaging respectively. Two clinical exams which are carried out with both a CBCT or a MDCT scanner were compared in terms of radiation dose. Dental CBCT scanners deliver lower doses for orthognathic patients whereas for temporal bone procedures the doses were similar. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
Robbins, Shawn M; Caplan, Ryan M; Aponte, Daniel I; St-Onge, Nancy
2017-10-01
External perturbations are utilized to challenge balance and mimic realistic balance threats in patient populations. The reliability of such protocols has not been established. The purpose was to examine test-retest reliability of balance testing with external perturbations. Healthy adults (n=34; mean age 23 years) underwent balance testing over two visits. Participants completed ten balance conditions in which the following parameters were combined: perturbation or non-perturbation, single or double leg, and eyes open or closed. Three trials were collected for each condition. Data were collected on a force plate and external perturbations were applied by translating the plate. Force plate center of pressure (CoP) data were summarized using 13 different CoP measures. Test-retest reliability was examined using intraclass correlation coefficients (ICC) and Bland-Altman plots. CoP measures of total speed and excursion in both anterior-posterior and medial-lateral directions generally had acceptable ICC values for perturbation conditions (ICC=0.46 to 0.87); however, many other CoP measures (e.g. range, area of ellipse) had unacceptable test-retest reliability (ICC<0.70). Improved CoP measures were present on the second visit indicating a potential learning effect. Non-perturbation conditions generally produced more reliable CoP measures than perturbation conditions during double leg standing, but not single leg standing. Therefore, changes to balance testing protocols that include external perturbations should be made to improve test-retest reliability and diminish learning including more extensive participant training and increasing the number of trials. CoP measures that consider all data points (e.g. total speed) are more reliable than those that only consider a few data points. Copyright © 2017 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Velders, Guus J. M.; Fahey, David W.; Daniel, John S.; Andersen, Stephen O.; McFarland, Mack
2015-12-01
Hydrofluorocarbons (HFCs) are manufactured for use as substitutes for ozone-depleting substances that are being phased out globally under Montreal Protocol regulations. While HFCs do not deplete ozone, many are potent greenhouse gases that contribute to climate change. Here, new global scenarios show that baseline emissions of HFCs could reach 4.0-5.3 GtCO2-eq yr-1 in 2050. The new baseline (or business-as-usual) scenarios are formulated for 10 HFC compounds, 11 geographic regions, and 13 use categories. The scenarios rely on detailed data reported by countries to the United Nations; projections of gross domestic product and population; and recent observations of HFC atmospheric abundances. In the baseline scenarios, by 2050 China (31%), India and the rest of Asia (23%), the Middle East and northern Africa (11%), and the USA (10%) are the principal source regions for global HFC emissions; and refrigeration (40-58%) and stationary air conditioning (21-40%) are the major use sectors. The corresponding radiative forcing could reach 0.22-0.25 W m-2 in 2050, which would be 12-24% of the increase from business-as-usual CO2 emissions from 2015 to 2050. National regulations to limit HFC use have already been adopted in the European Union, Japan and USA, and proposals have been submitted to amend the Montreal Protocol to substantially reduce growth in HFC use. Calculated baseline emissions are reduced by 90% in 2050 by implementing the North America Montreal Protocol amendment proposal. Global adoption of technologies required to meet national regulations would be sufficient to reduce 2050 baseline HFC consumption by more than 50% of that achieved with the North America proposal for most developed and developing countries.
NASA Astrophysics Data System (ADS)
Marijke, Grau; Vera, Abeln; Tobias, Vogt; Wilhelm, Bloch; Stefan, Schneider
2017-02-01
Artificial gravity protocols are used to improve g-tolerance of aviators and discussed as countermeasure during prolonged space flight. Little is known about the impact of artificial gravity on the red blood cells (RBC). The purpose of the study was to test how artificial gravity affects RBC deformability and aggregation, which are important determinants of microcirculation. Nine male subjects were exposed to two hypergravity protocols using a short arm human centrifuge: a continuous (CONT) protocol with constant +2 Gz for 30 min and an intermittent (INTER) protocol with repeated intervals of +2 Gz and rest. Blood was sampled pre and post interventions to measure basal blood parameters, RBC nitrite, RBC deformability, aggregation, and to determine the shear rate balancing aggregation and disaggregation (γ at dIsc min). To test for orthostasis effects, five male subjects were asked to stay for 46 min, corresponding to the length of the centrifuge protocols, with blood sampling pre and post intervention. Artificial gravity programs did not affect basal blood parameters or RBC nitrite levels; a marker for RBC deformability influencing nitric oxide. The INTER program did not affect any of the tested parameters. The CONT program did not remarkably affect RBC deformability or γ at dIsc min but significantly aggravated aggregation. Orthostasis effects were thus excluded. The results indicate that continuous artificial gravity, especially with higher g-forces applied, may negatively affect the RBC system and that for a prolonged space flight intermittent but not continuous artificial gravity might represent an appropriate countermeasure.
Zafeiridis, Andreas; Chatziioannou, Anastasia Chrysovalantou; Sarivasiliou, Haralambos; Kyparos, Antonios; Nikolaidis, Michalis G; Vrabas, Ioannis S; Pechlivanis, Alexandros; Zoumpoulakis, Panagiotis; Baskakis, Constantinos; Dipla, Konstantina; Theodoridis, Georgios A
2016-12-02
The overall metabolic/energetic stress that occurs during an acute bout of exercise is proposed to be the main driving force for long-term training adaptations. Continuous and high-intensity interval exercise protocols (HIIE) are currently prescribed to acquire the muscular and metabolic benefits of aerobic training. We applied 1 H NMR-based metabonomics to compare the overall metabolic perturbation and activation of individual bioenergetic pathways of three popular aerobic exercises matched for effort/strain. Nine men performed continuous, long-interval (3 min), and short-interval (30 s) bouts of exercise under isoeffort conditions. Blood was collected before and after exercise. The multivariate PCA and OPLS-DA models showed a distinct separation of pre- and postexercise samples in three protocols. The two models did not discriminate the postexercise overall metabolic profiles of the three exercise types. Analysis focused on muscle bioenergetic pathways revealed an extensive upregulation of carbohydrate-lipid metabolism and the TCA cycle in all three protocols; there were only a few differences among protocols in the postexercise abundance of molecules when long-interval bouts were performed. In conclusion, continuous and HIIE exercise protocols, when performed with similar effort/strain, induce comparable global metabolic response/stress despite their marked differences in work-bout intensities. This study highlights the importance of NMR metabonomics in comprehensive monitoring of metabolic consequences of exercise training in the blood of athletes and exercising individuals.
Saleem, Kashif; Derhab, Abdelouahid; Orgun, Mehmet A; Al-Muhtadi, Jalal; Rodrigues, Joel J P C; Khalil, Mohammed Sayim; Ali Ahmed, Adel
2016-03-31
The deployment of intelligent remote surveillance systems depends on wireless sensor networks (WSNs) composed of various miniature resource-constrained wireless sensor nodes. The development of routing protocols for WSNs is a major challenge because of their severe resource constraints, ad hoc topology and dynamic nature. Among those proposed routing protocols, the biology-inspired self-organized secure autonomous routing protocol (BIOSARP) involves an artificial immune system (AIS) that requires a certain amount of time to build up knowledge of neighboring nodes. The AIS algorithm uses this knowledge to distinguish between self and non-self neighboring nodes. The knowledge-building phase is a critical period in the WSN lifespan and requires active security measures. This paper proposes an enhanced BIOSARP (E-BIOSARP) that incorporates a random key encryption mechanism in a cost-effective manner to provide active security measures in WSNs. A detailed description of E-BIOSARP is presented, followed by an extensive security and performance analysis to demonstrate its efficiency. A scenario with E-BIOSARP is implemented in network simulator 2 (ns-2) and is populated with malicious nodes for analysis. Furthermore, E-BIOSARP is compared with state-of-the-art secure routing protocols in terms of processing time, delivery ratio, energy consumption, and packet overhead. The findings show that the proposed mechanism can efficiently protect WSNs from selective forwarding, brute-force or exhaustive key search, spoofing, eavesdropping, replaying or altering of routing information, cloning, acknowledgment spoofing, HELLO flood attacks, and Sybil attacks.
Saleem, Kashif; Derhab, Abdelouahid; Orgun, Mehmet A.; Al-Muhtadi, Jalal; Rodrigues, Joel J. P. C.; Khalil, Mohammed Sayim; Ali Ahmed, Adel
2016-01-01
The deployment of intelligent remote surveillance systems depends on wireless sensor networks (WSNs) composed of various miniature resource-constrained wireless sensor nodes. The development of routing protocols for WSNs is a major challenge because of their severe resource constraints, ad hoc topology and dynamic nature. Among those proposed routing protocols, the biology-inspired self-organized secure autonomous routing protocol (BIOSARP) involves an artificial immune system (AIS) that requires a certain amount of time to build up knowledge of neighboring nodes. The AIS algorithm uses this knowledge to distinguish between self and non-self neighboring nodes. The knowledge-building phase is a critical period in the WSN lifespan and requires active security measures. This paper proposes an enhanced BIOSARP (E-BIOSARP) that incorporates a random key encryption mechanism in a cost-effective manner to provide active security measures in WSNs. A detailed description of E-BIOSARP is presented, followed by an extensive security and performance analysis to demonstrate its efficiency. A scenario with E-BIOSARP is implemented in network simulator 2 (ns-2) and is populated with malicious nodes for analysis. Furthermore, E-BIOSARP is compared with state-of-the-art secure routing protocols in terms of processing time, delivery ratio, energy consumption, and packet overhead. The findings show that the proposed mechanism can efficiently protect WSNs from selective forwarding, brute-force or exhaustive key search, spoofing, eavesdropping, replaying or altering of routing information, cloning, acknowledgment spoofing, HELLO flood attacks, and Sybil attacks. PMID:27043572
Baker, Stephen B; Reid, Russell R; Burkey, Brooke; Bartlett, Scott P
2007-09-01
To shorten head frame wear time associated with external halo distraction (HD), we have adapted a protocol for maxillary distraction with the halo system that integrates plate fixation. All patients had a history of cleft lip and/or palate and maxillary retrusion > or = 8 mm. Five patients treated with this protocol and followed for at least 1 year were included in this study. The protocol included a 3-day latency period, variable maxillary distraction, and removal of the halo device with simultaneous rigid internal fixation. Two patients had a variable period of maxillomandibular fixation (MMF), which maintained the maxillary advancement and idealized intercuspal position while permitting further callus maturation. Cephalographs were obtained preoperatively, immediately following distractor removal, and 1 year after rigid internal fixation. The mean age at time of surgery was 18.7 years. The maxillary deficiency ranged from 8 to 15 mm (mean = 10.6 mm). All five patients demonstrated excellent occlusion. Cephalometric analysis 1-year post rigid internal fixation revealed minimal (<1 mm) skeletal relapse. Rapid maxillary distraction followed by MMF to maintain maxillary advancement may reduce halo device wear to 1 to 2 weeks. MMF optimizes occlusion by forcing the maxillary teeth into maximal intercuspal position. Rigid fixation is not only associated with less long-term relapse compared to nonrigid forms of fixation, but also minimizes the incidence of nonunion. This treatment protocol provides the advancement possible with distraction osteogenesis and the accuracy of orthognathic surgery, thereby minimizing external head frame wear.
Buldt, Andrew K; Allan, Jamie J; Landorf, Karl B; Menz, Hylton B
2018-02-23
Foot posture is a risk factor for some lower limb injuries, however the underlying mechanism is not well understood. Plantar pressure analysis is one technique to investigate the interaction between foot posture and biomechanical function of the lower limb. The aim of this review was to investigate the relationship between foot posture and plantar pressure during walking. A systematic database search was conducted using MEDLINE, CINAHL, SPORTDiscus and Embase to identify studies that have assessed the relationship between foot posture and plantar pressure during walking. Included studies were assessed for methodological quality. Meta-analysis was not conducted due to heterogeneity between studies. Inconsistencies included foot posture classification techniques, gait analysis protocols, selection of plantar pressure parameters and statistical analysis approaches. Of the 4213 citations identified for title and abstract review, sixteen studies were included and underwent quality assessment; all were of moderate methodological quality. There was some evidence that planus feet display higher peak pressure, pressure-time integral, maximum force, force-time integral and contact area predominantly in the medial arch, central forefoot and hallux, while these variables are lower in the lateral and medial forefoot. In contrast, cavus feet display higher peak pressure and pressure-time integral in the heel and lateral forefoot, while pressure-time integral, maximum force, force-time integral and contact area are lower for the midfoot and hallux. Centre of pressure was more laterally deviated in cavus feet and more medially deviated in planus feet. Overall, effect sizes were moderate, but regression models could only explain a small amount of variance in plantar pressure variables. Despite these significant findings, future research would benefit from greater methodological rigour, particularly in relation to the use of valid foot posture measurement techniques, gait analysis protocols, and standardised approaches for analysis and reporting of plantar pressure variables. Copyright © 2018 Elsevier B.V. All rights reserved.
The poison center role in biological and chemical terrorism.
Krenzelok, E P; Allswede, M P; Mrvos, R
2000-10-01
Nuclear, biological and chemical (NBC) terrorism countermeasures are a major priority with municipalities, healthcare providers, and the federal government. Significant resources are being invested to enhance civilian domestic preparedness by conducting education at every response level in anticipation of a NBC terroristic incident. The key to a successful response, in addition to education, is integration of efforts as well as thorough communication and understanding the role that each agency would play in an actual or impending NBC incident. In anticipation of a NBC event, a regional counter-terrorism task force was established to identify resources, establish responsibilities and coordinate the response to NBC terrorism. Members of the task force included first responders, hazmat, law enforcement (local, regional, national), government officials, the health department, and the regional poison information center. Response protocols were developed and education was conducted, culminating in all members of the response task force becoming certified NBC instructors. The poison center participated actively in 3 incidents of suspected biologic and chemical terrorism: an alleged anthrax-contaminated letter sent to a women's health clinic; a possible sarin gas release in a high school: and a potential anthrax/ebola contamination incident at an international airport. All incidents were determined hoaxes. The regional response plan establishes the poison information center as a common repository for all cases in a biological or chemical incident. The poison center is one of several critical components of a regional counterterrorism response force. It can conduct active and passive toxicosurveillance and identify sentinel events. To be responsive, the poison center staff must be knowledgeable about biological and chemical agents. The development of basic protocols and a standardized staff education program is essential. The use of the RaPiD-T (R-recognition, P-protection, D-detection, T-triage/treatment) course can provide basic staff education for responding to this important but rare consultation to the poison center.
FREQUENCY CONTENT OF CARTILAGE IMPACT FORCE SIGNAL REFLECTS ACUTE HISTOLOGIC STRUCTURAL DAMAGE.
Heiner, Anneliese D; Martin, James A; McKinley, Todd O; Goetz, Jessica E; Thedens, Daniel R; Brown, Thomas D
2012-10-01
The objective of this study was to determine if acute cartilage impact damage could be predicted by a quantification of the frequency content of the impact force signal. Osteochondral specimens excised from bovine lateral tibial plateaus were impacted with one of six impact energies. Each impact force signal underwent frequency analysis, with the amount of higher-frequency content (percent of frequency spectrum above 1 KHz) being registered. Specimens were histologically evaluated to assess acute structural damage (articular surface cracking and cartilage crushing) resulting from the impact. Acute histologic structural damage to the cartilage had higher concordance with the high-frequency content measure than with other mechanical impact measures (delivered impact energy, impact maximum stress, and impact maximum stress rate of change). This result suggests that the frequency content of an impact force signal, specifically the proportion of higher-frequency components, can be used as a quick surrogate measure for acute structural cartilage injury. Taking advantage of this relationship could reduce the time and expense of histological processing needed to morphologically assess cartilage damage, especially for purposes of initial screening when evaluating new impaction protocols.
NASA Astrophysics Data System (ADS)
Tabaczynski, Janelle R.; Stoll, Thomas; Shepard, Lauren; Siddiqui, Mohamed I. G.; Karkhanis, Nitant V.; Sommer, Kelsey; Siddiqui, Adnan H.; Ionita, Ciprian N.
2018-03-01
Patient-specific 3D printed phantoms (3DP) can reproduce accurate patient geometry and provide precise tools for Endovascular Image Guided Interventions (EIGI) simulations. We propose to build and test 3DP phantoms which mimic the arterial wall elasticity and surface properties and demonstrate their utility in comprehensive EIGI simulations. 3DP idealized and patient specific vascular phantoms were manufactured using Stratasys Objet 500 Connex 3. The idealized phantoms were created using a sine wave shape, patient specific phantoms were based on CT- angiography volumes. The phantoms were coated with a hydrophilic material to mimic vascular surface properties. We tested various endovascular procedures using an Interventional Device Testing Equipment (IDTE) 2000 and measured push/pull force used to actuate endovascular devices during EIGIs. The force needed to advance devices in neurovascular phantoms varied based on tortuosity, material and coating, ranging from -3 to 21 grams-force. Hydrophilic coating reduced maximum force from 21 to 4.8 grams-force in the same model. IDTE 2000 results of neurovascular models were compared to hand manipulation of guidewire access using a six-axis force sensor with forces ranging from -50 to 440 grams. The clot retriever tested in carotid models experienced most friction around tortuous bends ranging from -65 to -90 grams-force, with increasing rigidity of materials creating increased friction. Sine wave model forces varied from -2 to 105 grams. 3DP allows manufacturing of vascular phantoms with precise mechanical and surface properties which can be used for EIGI simulations for imaging protocol optimization and device behavior assessment.
1988-12-01
and do not refer to monitoring zones at McClellSn AFB. b Priority poLutant metals analyses also included U.S. EPA Methods 206.2, 245.1 and 270.2. EW a...sampling protocol, and the laboratory is audited routinely. Therefore, no corrective action other than good training and supervision is necessary. The same
The Soviet Concept of the ’Correlation of Forces’
1976-05-01
activity rests on a strong foundation of objective assessments and accurate information " and that "all party docu- ments devoted to domestic problems... tekst protokolov (Thjrd Regular Congress of the Russian Social-Demoeratic Worker s Party, 1905. roll Text of the Protocols) (Moscow: State...Literature. 1949), p. 248. U pointed out at the founding conference oi the Communist Information Bureau (Comlnform) In September 1947, the
2015-01-22
applications in fast single photon sources, quantum repeater circuitry, and high fidelity remote entanglement of atoms for quantum information protocols. We...fluorescence for motion/force sensors through Doppler velocimetry; and for the efficient collection of single photons from trapped ions for...Doppler velocimetry; and for the efficient collection of single photons from trapped ions for applications in fast single photon sources, quantum
Cochrane, J D
1996-01-01
The healthcare industry last year saw a continuation of the market-based reform revolution. Competition and economic forces are squeezing dollars out of the system but at varying rates depending on where you are in the country. Health benefit and hospital cost variations appear to be directly related to managed care penetration. Treatment protocol variations may also be related to economic incentives. The question is, will the variations disappear over the coming years?
1993-01-01
design and centrifugation protocols. A validated model of the cardiovascular and vestibular response to High Gradient Acceleration (HGA) is vital to...hermetically sealed compressors for long life Stirling and Pulse Tube Cryocoolers for spacecraft. State-of-the art compressors use unlubricated flexure...displacement and vibration cancellation. The inexpensive compressor proposed for Stirling and Pulse Tube cycle spacecraft cryocoolers makes use of
2010-09-01
policy or position of the Department of Defense or the U.S. government . IRB Protocol number _______N/A______. 12a. DISTRIBUTION / AVAILABILITY...72 3. GAO Case Study of Commercial Transformation in Decision Making on IS Acquisition Spending (Case Study Located in Appendix C...Program FRE Fleet Readiness Enterprise GAO government Accountability Office IOC Initial Operating Capability xvi IS Information
The South Eastern Europe Brigade: An Option for NATO-Led Peace Support Operations?
2011-06-10
Exercise CSSB Combat Service Support Battalion DOS Day of Supply DRO Disaster Relief Operations EOD Explosive Ordnance Disposal ETF Engineer Task...the adoption of the second Additional Protocol, the SEEBRIG member nations established an Engineer Task Force ( ETF ). The concept embeds purpose...capabilities, like the ETF structure, could be used as niche military capabilities by outside organizations that may need them. SEEBRIG engineer capabilities
Stressed Stability Techniques for Adjuvant Formulations.
Hasija, Manvi; Sheung, Anthony; Rahman, Nausheen; Ausar, Salvador F
2017-01-01
Stressed stability testing is crucial to the understanding of mechanisms of degradation and the effects of external stress factors on adjuvant stability. These studies vastly help the development of stability indicating tests and the selection of stabilizing conditions for long term storage. In this chapter, we provide detailed protocols for the execution of forced degradation experiments that evaluate the robustness of adjuvant formulations against thermal, mechanical, freeze-thawing, and photo stresses.
Evaluating the Effectiveness of IP Hopping via an Address Routing Gateway
2013-03-01
37 DARPA Defense Advanced Research Projects Agency . . . . . . . . . . . . . . . . . . . . . . . . . . 20 DHCP Dynamic Host...Protocol ( DHCP ) to force the changes. Through the use of a slightly intelligent DHCP server that leases IPs for a only a short time frame (on the order of...tens of minutes) and only offers IPs that have not been used recently, most networks already using DHCP can quickly change to a randomized scheme. This
OCONUS Compliance Assessment Protocols -- OEBGD (Air Force and Marine Corps Version)
2010-06-01
new and existing perchloroethylene (PCE) dry -cleaning machines must be controlled. • Electroplating and anodizing tanks must comply with one of...and other contaminants from the surfaces of the parts or to dry the parts. Cleaning machines that contain and use heated, nonboiling solvent to clean...cement kilns that combust MSW, internal combustion engines, gas turbines, or other combustion devices that combust landfill gases collected by
Moayeri, A; Mokhtari, T; Hedayatpour, A; Abbaszadeh, H-A; Mohammadpour, S; Ramezanikhah, H; Shokri, S
2018-04-01
Oxygen consumption increases many times during exercise, which can increase reactive oxygen species. It negatively affects fertility in male athletes. Melatonin is exerting a regulatory role at different levels of the hypothalamic-pituitary-gonadal axis. However, there is no evidence that the protective effects of melatonin persist after long duration exercise on the spermatogenesis. Therefore, this study was conducted to examine the impacts of melatonin on the testis following the administration of swimming exercise. Rats were separated into five different groups, including Control, sham M: received the solvent of melatonin, M: received melatonin, S: the exercise protocol, MS: received melatonin and the exercise protocol. After 8 weeks, animals were scarified and antioxidant enzymes levels of testes, spermatogenic cells apoptosis and sperm quality were measured. Swimming decreased all parameters of spermatozoa. Nevertheless, melatonin could significantly improve the progressive motility of spermatozoa in MS rats. Swimming caused an increased apoptosis of S group and decreased all antioxidant enzymes. Melatonin could drastically reduce apoptosis and increased these enzymes. Therefore, melatonin seems to induce the production of antioxidant enzymes of testicular tissues and diminish the extent of apoptotic changes caused by forced exercise on the testis, which can, in turn, ameliorate the sperm parameters. © 2017 Blackwell Verlag GmbH.
Peering at Brain Polysomes with Atomic Force Microscopy
Lunelli, Lorenzo; Bernabò, Paola; Bolner, Alice; Vaghi, Valentina; Marchioretto, Marta; Viero, Gabriella
2016-01-01
The translational machinery, i.e., the polysome or polyribosome, is one of the biggest and most complex cytoplasmic machineries in cells. Polysomes, formed by ribosomes, mRNAs, several proteins and non-coding RNAs, represent integrated platforms where translational controls take place. However, while the ribosome has been widely studied, the organization of polysomes is still lacking comprehensive understanding. Thus much effort is required in order to elucidate polysome organization and any novel mechanism of translational control that may be embedded. Atomic force microscopy (AFM) is a type of scanning probe microscopy that allows the acquisition of 3D images at nanoscale resolution. Compared to electron microscopy (EM) techniques, one of the main advantages of AFM is that it can acquire thousands of images both in air and in solution, enabling the sample to be maintained under near physiological conditions without any need for staining and fixing procedures. Here, a detailed protocol for the accurate purification of polysomes from mouse brain and their deposition on mica substrates is described. This protocol enables polysome imaging in air and liquid with AFM and their reconstruction as three-dimensional objects. Complementary to cryo-electron microscopy (cryo-EM), the proposed method can be conveniently used for systematically analyzing polysomes and studying their organization. PMID:27023752
Stress biomarker responses to different protocols of forced exercise in chronically stressed rats.
Radahmadi, Maryam; Alaei, Hojjatallah; Sharifi, Mohammad Reza; Hosseini, Nasrin
2017-01-01
Stress is one of the most significant causes of major health problems on a global scale. The beneficial effects of exercise on combating stress, however, are well-established. The present study investigated the stress biomarker responses, such as serum corticosterone, interlukin-1β, and glucose levels, to different (preventive, therapeutic, protective, and continuous) protocols of forced exercise under stress. Male rats were randomly allocated to the following five groups: stressed, preventive, therapeutic, protective, and continuous (and/or pre-stress, post-stress, stress-accompanied, and both pre-stress and stress-accompanied exercise respectively) exercise groups. Stress was applied 6 h/day for 21 days and the treadmill running was employed at a speed of 20-21 m/min for 21 and 42 days. The findings showed that the therapeutic, protective, and continuous exercises led to reduced corticosterone and glucose levels. Whereas, the preventive exercise did not reverse the stress responses, and that the therapeutic exercise led to a significant decline in serum interlukin-1β. It is concluded that protective, therapeutic, and, particularly, continuous exercises lead to significant reductions in serum corticosterone and the associated stress-induced hyperglycemia. Moreover, it appears that the timing and duration of exercise are the two factors contributing to changes in stress biomarker responses. Copyright © 2016 Elsevier Ltd. All rights reserved.
Thermal Changes During Guided Flapless Implant Site Preparation: A Comparative Study.
Sannino, Gianpaolo; Gherlone, Enrico F
To compare intrabony thermal changes induced by two different protocols for guided implant surgery during the whole drilling procedure. Two protocols for guided implant placement were evaluated in vitro using artificial bone cylinders. The control protocol provided traditional metal sleeves and a standard drilling sequence composed of four cylindrical triflute drills (cutting surface length = 16 mm). The test protocol provided a three-slot polyurethane sleeve and two cylindrical drills (second drill cutting surface length = 4 mm). Forty automated intermittent and graduated osteotomies (depth = 14 mm) were performed under external irrigation. Temperatures were measured in real time by three sensors at different depths (2, 8, and 13 mm). The temperature changes generated by the final drill of each protocol during the shearing and withdrawing processes were recorded as experimental results and subjected to the Student t test. Maximum temperature increases were recorded during the process of withdrawing in both protocols. In the control group, the mean thermal changes were 10.18°C, 8.61°C, and 5.78°C at depths of 2, 8, and 13 mm, respectively. In the test group, the mean thermal changes were 1.44°C, 4.46°C, and 3.58°C at depths of 2, 8, and 13 mm, respectively. The control group revealed statistically significantly (P < .0001) higher thermal changes than the test group, both in the superficial and deeper bone areas. An appropriate irrigation system could be crucial for thermal lowering during a guided implant osteotomy mainly in the coronal and middle third of the implant site. Copious irrigation should be provided during the withdrawing process since greater thermal increases could be expected. Lower temperature increases could be achieved, reducing drill-to-bone contact, ie, cutting surface length, due to short frictional force exposure.
Tufano, James J; Conlon, Jenny A; Nimphius, Sophia; Brown, Lee E; Petkovic, Alex; Frick, Justin; Haff, G Gregory
2017-09-01
Eight resistance-trained men completed three protocols separated by 48-96 hours. Each protocol included 36 repetitions with the same rest duration, but the frequency and length of rest periods differed. The cluster sets of four (CS4) protocol included 30 s of rest after the 4th, 8th, 16th, 20th, 28th, and 32nd repetition in addition to 120 s of rest after the 12th and 24th repetition. For the other two protocols, the total 420 s rest time of CS4 was redistributed to include nine sets of four repetitions (RR4) with 52.5 s of rest after every four repetitions, or 36 sets of single repetitions (RR1) with 12 s of rest after every repetition. Mean (MF) and peak (PF) force, velocity (MV and PV), and power output (MP and PP) were measured during 36 repetitions and were collapsed into 12 repetitions for analysis. Repeated measures ANOVA 3 (protocol) x 12 (repetition) showed a protocol x repetition interaction for PF, MV, PV, MP, and PP (p-values from <0.001 to 0.012). No interaction or main effect was present for MF. During RR1, MV, PV, MP, and PP were maintained, but decreased throughout every 4-repetition sequence during CS4 and RR4. During CS4 and RR4, PF was less following a rest period compared to subsequent repetitions, whereas PF was maintained during RR1. These data indicate that rest redistribution results in similar average kinetics and kinematics, but if total rest time is redistributed to create shorter but more frequent sets, kinetics and kinematics may remain more constant.
Tufano, James J.; Conlon, Jenny A.; Nimphius, Sophia; Brown, Lee E.; Petkovic, Alex; Frick, Justin; Haff, G. Gregory
2017-01-01
Abstract Eight resistance-trained men completed three protocols separated by 48-96 hours. Each protocol included 36 repetitions with the same rest duration, but the frequency and length of rest periods differed. The cluster sets of four (CS4) protocol included 30 s of rest after the 4th, 8th, 16th, 20th, 28th, and 32nd repetition in addition to 120 s of rest after the 12th and 24th repetition. For the other two protocols, the total 420 s rest time of CS4 was redistributed to include nine sets of four repetitions (RR4) with 52.5 s of rest after every four repetitions, or 36 sets of single repetitions (RR1) with 12 s of rest after every repetition. Mean (MF) and peak (PF) force, velocity (MV and PV), and power output (MP and PP) were measured during 36 repetitions and were collapsed into 12 repetitions for analysis. Repeated measures ANOVA 3 (protocol) x 12 (repetition) showed a protocol x repetition interaction for PF, MV, PV, MP, and PP (p-values from <0.001 to 0.012). No interaction or main effect was present for MF. During RR1, MV, PV, MP, and PP were maintained, but decreased throughout every 4-repetition sequence during CS4 and RR4. During CS4 and RR4, PF was less following a rest period compared to subsequent repetitions, whereas PF was maintained during RR1. These data indicate that rest redistribution results in similar average kinetics and kinematics, but if total rest time is redistributed to create shorter but more frequent sets, kinetics and kinematics may remain more constant. PMID:28828076
Sole, Christopher J.; Moir, Gavin L.; Davis, Shala E.; Witmer, Chad A.
2013-01-01
The purpose of this study was to determine the acute effects of heavy resistance exercise on agility performance in court-sport athletes. Five men (age: 20.6 ± 1.9 years; body mass: 79.36 ± 11.74 kg; body height: 1.93 ± 0.09 m) and five women (age 21.2 ± 2.7 years; body mass: 65.8 ± 10.18 kg; body height 1.77 ± 0.08 m) volunteered to participate in the present study. All subjects were NCAA Division II athletes who currently participated in tennis or basketball and all had previous resistance training experience of at least one year. In a counterbalanced design, agility performance during a 10 m shuttle test was assessed following either a dynamic warm-up (DW) or heavy resistance warm-up (HRW) protocol. The HRW protocol consisted of three sets of squats at 50, 60, and 90% of 1-RM. Agility performance was captured using an eight camera motion analysis system and the mechanical variables of stride length, stride frequency, stance time, flight time, average ground reaction force, as well as agility time were recorded. No significant differences were reported for the HRW and DW protocols for any of the mechanical variables (p>0.05), although there was a trend towards the HRW protocol producing faster agility times compared to the control protocol (p = 0.074). Based on the trend towards a significant effect, as well as individual results it is possible that HRW protocols could be used as an acute method to improve agility performance in some court-sport athletes. PMID:24511350
Michino, Mayako; Chen, Jianhan; Stevens, Raymond C; Brooks, Charles L
2010-08-01
Building reliable structural models of G protein-coupled receptors (GPCRs) is a difficult task because of the paucity of suitable templates, low sequence identity, and the wide variety of ligand specificities within the superfamily. Template-based modeling is known to be the most successful method for protein structure prediction. However, refinement of homology models within 1-3 A C alpha RMSD of the native structure remains a major challenge. Here, we address this problem by developing a novel protocol (foldGPCR) for modeling the transmembrane (TM) region of GPCRs in complex with a ligand, aimed to accurately model the structural divergence between the template and target in the TM helices. The protocol is based on predicted conserved inter-residue contacts between the template and target, and exploits an all-atom implicit membrane force field. The placement of the ligand in the binding pocket is guided by biochemical data. The foldGPCR protocol is implemented by a stepwise hierarchical approach, in which the TM helical bundle and the ligand are assembled by simulated annealing trials in the first step, and the receptor-ligand complex is refined with replica exchange sampling in the second step. The protocol is applied to model the human beta(2)-adrenergic receptor (beta(2)AR) bound to carazolol, using contacts derived from the template structure of bovine rhodopsin. Comparison with the X-ray crystal structure of the beta(2)AR shows that our protocol is particularly successful in accurately capturing helix backbone irregularities and helix-helix packing interactions that distinguish rhodopsin from beta(2)AR. (c) 2010 Wiley-Liss, Inc.
Delay and Disruption Tolerant Networking MACHETE Model
NASA Technical Reports Server (NTRS)
Segui, John S.; Jennings, Esther H.; Gao, Jay L.
2011-01-01
To verify satisfaction of communication requirements imposed by unique missions, as early as 2000, the Communications Networking Group at the Jet Propulsion Laboratory (JPL) saw the need for an environment to support interplanetary communication protocol design, validation, and characterization. JPL's Multi-mission Advanced Communications Hybrid Environment for Test and Evaluation (MACHETE), described in Simulator of Space Communication Networks (NPO-41373) NASA Tech Briefs, Vol. 29, No. 8 (August 2005), p. 44, combines various commercial, non-commercial, and in-house custom tools for simulation and performance analysis of space networks. The MACHETE environment supports orbital analysis, link budget analysis, communications network simulations, and hardware-in-the-loop testing. As NASA is expanding its Space Communications and Navigation (SCaN) capabilities to support planned and future missions, building infrastructure to maintain services and developing enabling technologies, an important and broader role is seen for MACHETE in design-phase evaluation of future SCaN architectures. To support evaluation of the developing Delay Tolerant Networking (DTN) field and its applicability for space networks, JPL developed MACHETE models for DTN Bundle Protocol (BP) and Licklider/Long-haul Transmission Protocol (LTP). DTN is an Internet Research Task Force (IRTF) architecture providing communication in and/or through highly stressed networking environments such as space exploration and battlefield networks. Stressed networking environments include those with intermittent (predictable and unknown) connectivity, large and/or variable delays, and high bit error rates. To provide its services over existing domain specific protocols, the DTN protocols reside at the application layer of the TCP/IP stack, forming a store-and-forward overlay network. The key capabilities of the Bundle Protocol include custody-based reliability, the ability to cope with intermittent connectivity, the ability to take advantage of scheduled and opportunistic connectivity, and late binding of names to addresses.
Folkard, S; Minors, D S; Waterhouse, J M
1984-01-01
Three groups of four healthy volunteers lived in an isolation unit for 24 days. During this time they lived by a clock which, unknown to themselves, ran progressively faster so that, by real time, the 'day' decreased from 24.0 to 22.0 h in length. Throughout this protocol, the subjects lived a regular regimen of sleep, waking and meals based upon their 'local' time clock. They collected regular urine samples that were analysed for a variety of constituents. Rectal temperature was also recorded automatically throughout. The effects of such a protocol upon circadian rhythmicity in these variables were investigated by a variety of techniques including cosinor analysis. The results showed that the temperature rhythm was less able to adjust to a shortening 'day' than were the urinary variables, with the possible exception of potassium; that is, the protocol forced an internal desynchronization to exist between different variables. These results are discussed in terms of both the possibility that more than one internal circadian clock might exist and the direct effect that sleep exerts upon the expression of circadian rhythms. PMID:6512693
Adams, Jenny; Pullum, Gwen; Stafford, Pamala; Hanners, Nava; Hartman, Julie; Strauss, Danielle; Hubbard, Matt; Lawrence, Anne; Anderson, Valerie; McCullough, Tiffany
2008-01-01
Physician advice and restrictions to patients following a cardiac event can, in some instances, lead patients to be fearful regarding their activities even to the point of inactivity. The purpose of this study was to test whether lawn mowing, one of the activities most strongly discouraged after coronary artery bypass surgery, could be safely performed in a supervised setting. Subjects participated in a 6-session simulated lawn-mowing protocol, calibrated to match the push and pull forces of using an outdoor nonpropelled lawn mower. Plain chest radiographs were taken before and after the protocol period. During each session, subjects' sternums were carefully palpated and electrocardiograms, heart rates, and blood pressures were monitored. None of the 13 subjects experienced adverse arrhythmia events or detrimental heart rate, blood pressure, or sternal palpation findings that led to study discontinuation. The radiographs taken after protocol completion showed stable sternal wires with no evidence of sternal dehiscence. Simulated lawn mowing did not negatively affect the sternal incision, electrocardiogram findings, blood pressure, or heart rate in this small sample.
Applying Pose Clustering and MD Simulations To Eliminate False Positives in Molecular Docking.
Makeneni, Spandana; Thieker, David F; Woods, Robert J
2018-03-26
In this work, we developed a computational protocol that employs multiple molecular docking experiments, followed by pose clustering, molecular dynamic simulations (10 ns), and energy rescoring to produce reliable 3D models of antibody-carbohydrate complexes. The protocol was applied to 10 antibody-carbohydrate co-complexes and three unliganded (apo) antibodies. Pose clustering significantly reduced the number of potential poses. For each system, 15 or fewer clusters out of 100 initial poses were generated and chosen for further analysis. Molecular dynamics (MD) simulations allowed the docked poses to either converge or disperse, and rescoring increased the likelihood that the best-ranked pose was an acceptable pose. This approach is amenable to automation and can be a valuable aid in determining the structure of antibody-carbohydrate complexes provided there is no major side chain rearrangement or backbone conformational change in the H3 loop of the CDR regions. Further, the basic protocol of docking a small ligand to a known binding site, clustering the results, and performing MD with a suitable force field is applicable to any protein ligand system.
Braun, Benedikt J; Bushuven, Eva; Hell, Rebecca; Veith, Nils T; Buschbaum, Jan; Holstein, Joerg H; Pohlemann, Tim
2016-02-01
Weight bearing after lower extremity fractures still remains a highly controversial issue. Even in ankle fractures, the most common lower extremity injury no standard aftercare protocol has been established. Average non weight bearing times range from 0 to 7 weeks, with standardised, radiological healing controls at fixed time intervals. Recent literature calls for patient-adapted aftercare protocols based on individual fracture and load scenarios. We show the clinical feasibility and first results of a new, insole embedded gait analysis tool for continuous monitoring of gait, load and activity. Ten patients were monitored with a new, independent gait analysis insole for up to 3 months postoperatively. Strict 20 kg partial weight bearing was ordered for 6 weeks. Overall activity, load spectrum, ground reaction forces, clinical scoring and general health data were recorded and correlated. Statistical analysis with power analysis, t-test and Spearman correlation was performed. Only one patient completely adhered to the set weight bearing limit. Average time in minutes over the limit was 374 min. Based on the parameters load, activity, gait time over 20 kg weight bearing and maximum ground reaction force high and low performers were defined after 3 weeks. Significant difference in time to painless full weight bearing between high and low performers was shown. Correlation analysis revealed a significant correlation between weight bearing and clinical scoring as well as pain (American Orthopaedic Foot and Ankle Society (AOFAS) Score rs=0.74; Olerud-Molander Score rs=0.93; VAS pain rs=-0.95). Early, continuous gait analysis is able to define aftercare performers with significant differences in time to full painless weight bearing where clinical or radiographic controls could not. Patient compliance to standardised weight bearing limits and protocols is low. Highly individual rehabilitation patterns were seen in all patients. Aftercare protocols should be adjusted to real-time patient conditions, rather than fixed intervals and limits. With a real-time measuring device high performers could be identified and influenced towards optimal healing conditions early, while low performers are recognised and missing healing influences could be corrected according to patient condition. Copyright © 2015 Elsevier Ltd. All rights reserved.
Pinto, Ana P; da Rocha, Alisson L; Oliveira, Luciana da C; Morais, Gustavo P; de Vicente, Larissa G; Cintra, Dennys E; Pauli, José R; Moura, Leandro P; Ropelle, Eduardo R; da Silva, Adelino S R
2017-01-01
Recently, we demonstrated that different running overtraining (OT) protocols with the same external load, but performed downhill (OTR/down), uphill (OTR/up), and without inclination (OTR), led to hepatic fat accumulation. As the disruption of endoplasmic reticulum (ER) homeostasis is linked to animal models of fatty liver disease, we investigated the effects of these OT models on the proteins related to ER stress (i.e., BiP, inositol-requiring enzyme 1, protein kinase RNA-like endoplasmic reticulum kinase, eIF2alpha, ATF6beta, and glucose-regulated protein 94) and apoptosis (C/EBP-homologous protein, Caspase-3, 4, and 12, Bax, and tumor necrosis factor receptor-associated factor 2) in livers of C57BL/6 mice. Also, aerobic training can attenuate cardiac ER stress and improve exercise capacity. Therefore, we investigated whether the decrease in performance induced by our OT protocols is linked to ER stress and apoptosis in mouse hearts. The rodents were divided into six groups: naïve (N, sedentary mice), control (CT, sedentary mice submitted to the performance evaluations), trained (TR), OTR/down, OTR/up, and OTR groups. Rotarod, incremental load, exhaustive, and grip force tests were used to evaluate performance. After the grip force test, the livers and cardiac muscles (i.e., left ventricle) were removed and used for immunoblotting. All of the OT protocols led to similar responses in the performance parameters and displayed significantly lower hepatic ATF6beta values compared to the N group. The OTR/down group exhibited lower liver cleaved caspase-3 values compared to the CT group. However, the other proteins related to ER stress and apoptosis were not modulated. Also, the cardiac proteins related to ER stress and apoptosis were not modulated in the experimental groups. In conclusion, the OT protocols decreased the levels of hepatic ATF6beta, and the OTR/down group decreased the levels of hepatic cleaved caspase-3. Also, the decrease in performance induced by our OT models is not associated with ER stress and apoptosis in mice hearts.
Vanduyfhuys, Louis; Vandenbrande, Steven; Verstraelen, Toon; Schmid, Rochus; Waroquier, Michel; Van Speybroeck, Veronique
2015-05-15
QuickFF is a software package to derive accurate force fields for isolated and complex molecular systems in a quick and easy manner. Apart from its general applicability, the program has been designed to generate force fields for metal-organic frameworks in an automated fashion. The force field parameters for the covalent interaction are derived from ab initio data. The mathematical expression of the covalent energy is kept simple to ensure robustness and to avoid fitting deficiencies as much as possible. The user needs to produce an equilibrium structure and a Hessian matrix for one or more building units. Afterward, a force field is generated for the system using a three-step method implemented in QuickFF. The first two steps of the methodology are designed to minimize correlations among the force field parameters. In the last step, the parameters are refined by imposing the force field parameters to reproduce the ab initio Hessian matrix in Cartesian coordinate space as accurate as possible. The method is applied on a set of 1000 organic molecules to show the easiness of the software protocol. To illustrate its application to metal-organic frameworks (MOFs), QuickFF is used to determine force fields for MIL-53(Al) and MOF-5. For both materials, accurate force fields were already generated in literature but they requested a lot of manual interventions. QuickFF is a tool that can easily be used by anyone with a basic knowledge of performing ab initio calculations. As a result, accurate force fields are generated with minimal effort. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.
The Radiative Forcing Model Intercomparison Project (RFMIP): Experimental protocol for CMIP6
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pincus, Robert; Forster, Piers M.; Stevens, Bjorn
The phrasing of the first of three questions motivating CMIP6 – “How does the Earth system respond to forcing?” – suggests that forcing is always well-known, yet the radiative forcing to which this question refers has historically been uncertain in coordinated experiments even as understanding of how best to infer radiative forcing has evolved. The Radiative Forcing Model Intercomparison Project (RFMIP) endorsed by CMIP6 seeks to provide a foundation for answering the question through three related activities: (i) accurate characterization of the effective radiative forcing relative to a near-preindustrial baseline and careful diagnosis of the components of this forcing; (ii) assessment ofmore » the absolute accuracy of clear-sky radiative transfer parameterizations against reference models on the global scales relevant for climate modeling; and (iii) identification of robust model responses to tightly specified aerosol radiative forcing from 1850 to present. Complete characterization of effective radiative forcing can be accomplished with 180 years (Tier 1) of atmosphere-only simulation using a sea-surface temperature and sea ice concentration climatology derived from the host model's preindustrial control simulation. Assessment of parameterization error requires trivial amounts of computation but the development of small amounts of infrastructure: new, spectrally detailed diagnostic output requested as two snapshots at present-day and preindustrial conditions, and results from the model's radiation code applied to specified atmospheric conditions. In conclusion, the search for robust responses to aerosol changes relies on the CMIP6 specification of anthropogenic aerosol properties; models using this specification can contribute to RFMIP with no additional simulation, while those using a full aerosol model are requested to perform at least one and up to four 165-year coupled ocean–atmosphere simulations at Tier 1.« less
The Radiative Forcing Model Intercomparison Project (RFMIP): Experimental protocol for CMIP6
Pincus, Robert; Forster, Piers M.; Stevens, Bjorn
2016-09-27
The phrasing of the first of three questions motivating CMIP6 – “How does the Earth system respond to forcing?” – suggests that forcing is always well-known, yet the radiative forcing to which this question refers has historically been uncertain in coordinated experiments even as understanding of how best to infer radiative forcing has evolved. The Radiative Forcing Model Intercomparison Project (RFMIP) endorsed by CMIP6 seeks to provide a foundation for answering the question through three related activities: (i) accurate characterization of the effective radiative forcing relative to a near-preindustrial baseline and careful diagnosis of the components of this forcing; (ii) assessment ofmore » the absolute accuracy of clear-sky radiative transfer parameterizations against reference models on the global scales relevant for climate modeling; and (iii) identification of robust model responses to tightly specified aerosol radiative forcing from 1850 to present. Complete characterization of effective radiative forcing can be accomplished with 180 years (Tier 1) of atmosphere-only simulation using a sea-surface temperature and sea ice concentration climatology derived from the host model's preindustrial control simulation. Assessment of parameterization error requires trivial amounts of computation but the development of small amounts of infrastructure: new, spectrally detailed diagnostic output requested as two snapshots at present-day and preindustrial conditions, and results from the model's radiation code applied to specified atmospheric conditions. In conclusion, the search for robust responses to aerosol changes relies on the CMIP6 specification of anthropogenic aerosol properties; models using this specification can contribute to RFMIP with no additional simulation, while those using a full aerosol model are requested to perform at least one and up to four 165-year coupled ocean–atmosphere simulations at Tier 1.« less
Purevsuren, Tserenchimed; Dorj, Ariunzaya; Kim, Kyungsoo; Kim, Yoon Hyuk
2016-04-01
The computational modeling approach has commonly been used to predict knee joint contact forces, muscle forces, and ligament loads during activities of daily living. Knowledge of these forces has several potential applications, for example, within design of equipment to protect the knee joint from injury and to plan adequate rehabilitation protocols, although clinical applications of computational models are still evolving and one of the limiting factors is model validation. The objective of this study was to extend previous modeling technique and to improve the validity of the model prediction using publicly available data set of the fifth "Grand Challenge Competition to Predict In Vivo Knee Loads." A two-stage modeling approach, which combines conventional inverse dynamic analysis (the first stage) with a multi-body subject-specific lower limb model (the second stage), was used to calculate medial and lateral compartment contact forces. The validation was performed by direct comparison of model predictions and experimental measurement of medial and lateral compartment contact forces during normal and turning gait. The model predictions of both medial and lateral contact forces showed strong correlations with experimental measurements in normal gait (r = 0.75 and 0.71) and in turning gait trials (r = 0.86 and 0.72), even though the current technique over-estimated medial compartment contact forces in swing phase. The correlation coefficient, Sprague and Geers metrics, and root mean squared error indicated that the lateral contact forces were predicted better than medial contact forces in comparison with the experimental measurements during both normal and turning gait trials. © IMechE 2016.
da Rosa, João Gabriel Santos; Barcellos, Heloísa Helena de Alcântara; Idalencio, Renan; Marqueze, Alessandra; Fagundes, Michele; Rossini, Mainara; Variani, Cristiane; Balbinoti, Francine; Tietböhl, Tássia Michele Huff; Rosemberg, Denis Broock; Barcellos, Leonardo José Gil
2017-02-01
In this study, we show that an adaptation of the spinning test can be used as a model to study the exercise-exhaustion-recovery paradigm in fish. This forced swimming test promotes a wide range of changes in the hypothalamus-pituitary-interrenal axis functioning, intermediary metabolism, as well in fish behavior at both exercise and recovery periods. Our results pointed that this adapted spinning test can be considered a valuable tool for evaluating drugs and contaminant effects on exercised fish. This can be a suitable protocol both to environmental-to evaluate contaminants that act in fish energy mobilization and recovery after stressors-and translational perspectives-effects of drugs on exercised or stressed humans.
Smith, David; da Silva, Manuela; Jackson, Julian; Lyal, Christopher
2017-03-01
Working with genetic resources and associated data requires greater attention since the Nagoya Protocol on Access and Benefit Sharing (ABS) came into force in October 2014. Biologists must ensure that they have legal clarity in how they can and cannot use the genetic resources on which they carry out research. Not only must they work within the spirit in the Convention on Biological Diversity (https://www.cbd.int/convention/articles/default.shtml?a=cbd-02) but also they may have regulatory requirements to meet. Although the Nagoya Protocol was negotiated and agreed globally, it is the responsibility of each country that ratifies it to introduce their individual implementing procedures and practices. Many countries in Europe, such as the UK, have chosen not to put access controls in place at this time, but others already have laws enacted providing ABS measures under the Convention on Biological Diversity or specifically to implement the Nagoya Protocol. Access legislation is in place in many countries and information on this can be found at the ABS Clearing House (https://absch.cbd.int/). For example, Brazil, although not a Party to the Nagoya Protocol at the time of writing, has Law 13.123 which entered into force on 17 November 2015, regulated by Decree 8.772 which was published on 11 May 2016. In this case, export of Brazilian genetic resources is not allowed unless the collector is registered in the National System for Genetic Heritage and Associated Traditional Knowledge Management (SisGen). The process entails that a foreign scientist must first of all be registered working with someone in Brazil and have authorization to collect. The enactment of European Union Regulation po. 511/2014 implements Nagoya Protocol elements that govern compliance measures for users and offers the opportunity to demonstrate due diligence in sourcing their organisms by selecting from holdings of 'registered collections'. The UK has introduced a Statutory Instrument that puts in place enforcement measures within the UK to implement this European Union Regulation; this is regulated by Regulatory Delivery, Department for Business, Energy and Industrial Strategies. Scientific communities, including the private sector, individual institutions and organizations, have begun to design policy and best practices for compliance. Microbiologists and culture collections alike need to be aware of the legislation of the source country of the materials they use and put in place best practices for compliance; such best practice has been drafted by the Microbial Resource Research Infrastructure, and other research communities such as the Consortium of European Taxonomic Facilities, the Global Genome Biodiversity Network and the International Organisation for Biological Control have published best practice and/or codes of conduct to ensure legitimate exchange and use of genetic resources.
Influence of vision and dental occlusion on body posture in pilots.
Baldini, Alberto; Nota, Alessandro; Cravino, Gaia; Cioffi, Clementina; Rinaldi, Antonio; Cozza, Paola
2013-08-01
Air force pilots have great postural control, movement coordination, motor learning, and motor transformation. They undergo abnormal stresses during flight that affect their organs and systems, with consequences such as barodontalgia, bruxism, TMJ dysfunctions, and cervical pain. The aim of this study was to evaluate the influence of dental occlusion and vision on their body posture. In collaboration with the "A. Mosso" Legal Medical Institute (Aeronautica Militare), two groups, consisting of 20 air force and 20 civilian pilots, were selected for the study using a protocol approved by the Italian Air Force. An oral examination and a force platform test were performed in order to evaluate the subjects' postural system efficiency. A MANOVA (Multivariate analysis of variance) analysis was performed by using the Wilkes' criterion, in order to statistically evaluate the influence of each factor. Both the sway area and velocity parameters are very strongly influenced by vision: the sway area increases by approximately 32% and the sway velocity increases by approximately 50% when the pilot closes his eyes. Only the sway area parameter was significantly influenced by the mandibular position: the mandibular position with eyes open changed the sway area by about 51% and with eyes closed by about 40%. No statistically significant differences were found between air force and civilian pilots. The results of this analysis show that occlusion and visual function could influence posture in air force and civilian pilots.
Effects of hypoxia and hypercapnia on geniohyoid contractility and endurance.
Salmone, R J; Van Lunteren, E
1991-08-01
Sleep apnea and other respiratory diseases produce hypoxemia and hypercapnia, factors that adversely affect skeletal muscle performance. To examine the effects of these chemical alterations on force production by an upper airway dilator muscle, the contractile and endurance characteristics of the geniohyoid muscle were examined in situ during severe hypoxia (arterial PO2 less than 40 Torr), mild hypoxia (PO2 45-65 Torr), and hypercapnia (PCO2 55-80 Torr) and compared with hyperoxic-normocapnic conditions in anesthetized cats. Muscles were studied at optimal length, and contractile force was assessed in response to supramaximal electrical stimulation of the hypoglossal nerve (n = 7 cats) or geniohyoid muscle (n = 2 cats). There were no significant changes in the twitch kinetics or force-frequency curve of the geniohyoid muscle during hypoxia or hypercapnia. However, the endurance of the geniohyoid, as reflected in the fatigue index (ratio of force at 2 min to initial force in response to 40-Hz stimulation at a duty cycle 0.33), was significantly reduced by severe hypoxia but not by hypercapnia or mild hypoxia. In addition, the downward shift in the force-frequency curve after the repetitive stimulation protocol was greater during hypoxia than hyperoxia, especially at higher frequencies. In conclusion, the ability of the geniohyoid muscle to maintain force output during high levels of activation is adversely affected by severe hypoxia but not mild hypoxia or hypercapnia. However, none of these chemical perturbations affected muscle contractility acutely.
Holviala, Jarkko H S; Sallinen, Janne M; Kraemer, William J; Alen, Markku J; Häkkinen, Keijo K T
2006-05-01
Progressive strength training can lead to substantial increases in maximal strength and mass of trained muscles, even in older women and men, but little information is available about the effects of strength training on functional capabilities and balance. Thus, the effects of 21 weeks of heavy resistance training--including lower loads performed with high movement velocities--twice a week on isometric maximal force (ISOmax) and force-time curve (force produced in 500 milliseconds, F0-500) and dynamic 1 repetition maximum (1RM) strength of the leg extensors, 10-m walking time (10WALK) and dynamic balance test (DYN.D) were investigated in 26 middle-aged (MI; 52.8 +/- 2.4 years) and 22 older women (O; 63.8 +/- 3.8 years). 1RM, ISOmax, and F0-500 increased significantly in MI by 28 +/- 10%, 20 +/- 19%, 31 +/- 34%, and in O by 27 +/- 8%, 20 +/- 16%, 18 +/- 45%, respectively. 10WALK (MI and O, p < 0.001) shortened and DYN.D improved (MI and O, p < 0.001). The present strength-training protocol led to large increases in maximal and explosive strength characteristics of leg extensors and in walking speed, as well to an improvement in the present dynamic balance test performance in both age groups. Although training-induced increase in explosive strength is an important factor for aging women, there are other factors that contribute to improvements in dynamic balance capacity. This study indicates that total body heavy resistance training, including explosive dynamic training, may be applied in rehabilitation or preventive exercise protocols in aging women to improve dynamic balance capabilities.
The acute effects of moderately loaded concentric-only quarter squats on vertical jump performance.
Crum, Aaron J; Kawamori, Naoki; Stone, Michael H; Haff, G Gregory
2012-04-01
Limited research exists examining the effect of moderately loaded conditioning activities that are employed as part of a strength-power potentiating complex (SPPC). Additionally, no studies to date have explored the effects of using a concentric-only quarter back squat protocol as part of an SPPC. Therefore, the purpose of this study was to examine the effects of a moderately loaded (50-65% of 1RM) concentric-only quarter back squat protocol on the occurrence of potentiation effects at various time points. Twenty men who could quarter back squat a minimum of 2.4 times their body mass (3.7 ± 0.7 kg·per body mass) participated in this investigation. All subjects participated in 3 conditions: control (CT), a 50% of 1RM trial (50POT), and a 65% of 1RM trial (65POT). One minute before each condition, a maximal countermovement vertical jump (CMJ) was performed. One minute later, the subject performed 1 of 3 conditions: CT condition, 50POT, or 65POT, followed by vertical jumps at 0.5, 3, 5, 10, and 15 minutes after conditioning activity. A force plate was used to quantify displacement, peak power output, peak force, and the rate of force development for each CMJ. There were no significant differences (p > 0.05) in any of the performance measures quantified during the CMJ trials when comparing the CT, 50POT, and 65POT treatment conditions. However, 48% of the subjects demonstrated some degree of potentiation at the 30 seconds after completing the 65POT trial, but this percent increase was not statistically significant. From a practical perspective, if the goal of the SPPC is to create a maximization of the potentiation effect, moderately loaded activities may not be the best alternative.
The acute effect of a plyometric stimulus on jump performance in professional rugby players.
Tobin, Daniel P; Delahunt, Eamonn
2014-02-01
Post-activation potentiation (PAP) is the elevation of motor performance to a higher level in response to a conditioning stimulus. Extensive research exists examining the PAP effect after a heavy resistance exercise. However, there is limited research examining the PAP effect after a plyometric stimulus. This study was designed to examine whether a plyometric stimulus could produce a PAP effect comparable to that typically reported with a heavy resistance protocol. Importantly, it was hypothesized that the PAP effect would exist without the same levels of acute fatigue resulting from a heavy stimulus, thus allowing improvement in performance within a short rest interval range. Twenty professional rugby players were recruited for the study. Subjects performed 2 countermovement jumps (CMJs) at baseline and at 1, 3, and 5 minutes after a plyometric stimulus consisting of 40 jumps. Two separate 1-way repeated-measures analyses of variance were conducted to compare the dependent variables CMJ height and peak force at the 4 time points. Results of the Bonferroni adjusted pairwise comparisons indicated that jump height and peak force before plyometric exercises were significantly lower than all other time points (p < 0.01). The main finding of this study indicates that a series of plyometric exercises causes a significant acute enhancement in CMJ height (p < 0.01) and peak force (p < 0.01) throughout the rest interval range of 1-5 minutes. The plyometric series induced an improvement in CMJ height comparable to that reported elsewhere after a heavy lifting stimulus but without the need for a prolonged rest interval. Performing repeated series of plyometric jumps appears to be an efficient method of taking advantage of the PAP phenomenon, thus possibly eliminating the need for a complex training protocol.
The prevalence of reversible airway obstruction in professional football players.
Ross, R G
2000-12-01
To determine the prevalence of reversible airway obstruction in a group of professional football training camp participants. All attendees at a Canadian Football League team rookie preseason training camp were invited to participate in a protocol designed to elicit symptoms and signs of reversible airway obstruction (asthma) during the initial preparticipation examination. Those agreeing to the protocol completed a questionnaire containing standardized inquiries about a past history of asthma and the presence of symptoms. Participants then underwent spirometry testing to determine lung function before and after receiving a standardized dose of bronchodilator medication. Players showing evidence of airway obstruction during initial testing and still on the team roster underwent repeat spirometry testing and formal pulmonary function testing during the football season. The follow-up pulmonary function tests were performed to determine those that might benefit from treatment for asthma. Nineteen of 34 (56%) players agreeing to participate had significant reversible airway obstruction as defined by a 12% or greater reversibility in forced expiratory volume in one second (FEV1), peak expiratory flow rate (PEFR), and/or forced expiratory flow rate between 25 and 75% of forced vital capacity (FEF 25-75). In most participants, the diagnosis was made on the basis of spirometry alone. Of those testing positive during initial inquiry, 88% remained positive on repeat spirometry, and 73% had reversible airway obstruction during more stringently controlled hospital-based pulmonary function testing. Those players treated for previously undiagnosed asthma noted an improvement in subjective athletic performance during the football season. Based on the remarkably high prevalence of undiagnosed asthma in this group, it may prove worthwhile to test elite football players using lung function parameters.
Ia Afferent input alters the recruitment thresholds and firing rates of single human motor units.
Grande, G; Cafarelli, E
2003-06-01
Vibration of the patellar tendon recruits motor units in the knee extensors via excitation of muscle spindles and subsequent Ia afferent input to the alpha-motoneuron pool. Our first purpose was to determine if the recruitment threshold and firing rate of the same motor unit differed when recruited involuntarily via reflex or voluntarily via descending spinal pathways. Although Ia input is excitatory to the alpha-motoneuron pool, it has also been shown paradoxically to inhibit itself. Our second purpose was to determine if vibration of the patellar tendon during a voluntary knee extension causes a change in the firing rate of already recruited motor units. In the first protocol, 10 subjects voluntarily reproduced the same isometric force profile of the knee extensors that was elicited by vibration of the patellar tendon. Single motor unit recordings from the vastus lateralis (VL) were obtained with tungsten microelectrodes and unitary behaviour was examined during both reflex and voluntary knee extensions. Recordings from 135 single motor units showed that both recruitment thresholds and firing rates were lower during reflex contractions. In the second protocol, 7 subjects maintained a voluntary knee extension at 30 N for approximately 40-45 s. Three bursts of patellar tendon vibration were superimposed at regular intervals throughout the contraction and changes in the firing rate of already recruited motor units were examined. A total of 35 motor units were recorded and each burst of superimposed vibration caused a momentary reduction in the firing rates and recruitment of additional units. Our data provide evidence that Ia input modulates the recruitment thresholds and firing rates of motor units providing more flexibility within the neuromuscular system to grade force at low levels of force production.
Borniger, Jeremy C; Maurya, Santosh K; Periasamy, Muthu; Nelson, Randy J
2014-10-01
The circadian system is primarily entrained by the ambient light environment and is fundamentally linked to metabolism. Mounting evidence suggests a causal relationship among aberrant light exposure, shift work, and metabolic disease. Previous research has demonstrated deleterious metabolic phenotypes elicited by chronic (>4 weeks) exposure to dim light at night (DLAN) (∼ 5 lux). However, the metabolic effects of short-term (<2 weeks) exposure to DLAN are unspecified. We hypothesized that metabolic alterations would arise in response to just 2 weeks of DLAN. Specifically, we predicted that mice exposed to dim light would gain more body mass, alter whole body metabolism, and display altered body temperature (Tb) and activity rhythms compared to mice maintained in dark nights. Our data largely support these predictions; DLAN mice gained significantly more mass, reduced whole body energy expenditure, increased carbohydrate over fat oxidation, and altered temperature circadian rhythms. Importantly, these alterations occurred despite similar activity locomotor levels (and rhythms) and total food intake between groups. Peripheral clocks are potently entrained by body temperature rhythms, and the deregulation of body temperature we observed may contribute to metabolic problems due to "internal desynchrony" between the central circadian oscillator and temperature sensitive peripheral clocks. We conclude that even relatively short-term exposure to low levels of nighttime light can influence metabolism to increase mass gain.
Guilding, Clare; Scott, Fiona; Bechtold, David A; Brown, Timothy M; Wegner, Sven; Piggins, Hugh D
2013-01-01
Within the core molecular clock, protein phosphorylation and degradation play a vital role in determining circadian period. The ‘after-hours’ (Afh) mutation in mouse slows the degradation of the core clock protein Cryptochrome, lengthening the period of the molecular clock in the suprachiasmatic nuclei (SCN) and behavioural wheel-running rhythms. However, we do not yet know how the Afh mutation affects other aspects of physiology or the activity of circadian oscillators in other brain regions. Here we report that daily rhythms of metabolism and ingestive behaviours are altered in these animals, as are PERIOD2::LUCIFERASE (PER2::LUC) rhythms in mediobasal hypothalamic nuclei, which influence these behaviours. Overall there is a trend towards period lengthening and a decrease in amplitude of PER2::LUC rhythms throughout the brain. Imaging of single cells from the arcuate and dorsomedial hypothalamic nuclei revealed this reduction in tissue oscillator amplitude to be due to a decrease in the amplitude, rather than a desynchrony, of single cells. Consistent with existing models of oscillator function, this cellular phenotype was associated with a greater susceptibility to phase-shifting stimuli in vivo and in vitro, with light evoking high-amplitude Type 0 resetting in Afh mutant mice. Together, these findings reveal unexpected consequences of the Afh mutation on the amplitude and synchrony of individual cellular oscillators in the SCN. PMID:23207594
Overview Environmental Assessment for the Space Based Infrared System (SBIRS)
1996-12-01
to HCl at various concentrations and durations (NASA, 1980). These insects were the honey bee , corn earworm, and lacewing. At the concentrations...bodily injury regardless of age, gender, or child-bearing status. Air Force Occupational Safety and Health Standard 48-9 establishes PELs for RF...contribute to harmful effects on the O3 layer. The actions detailed in Title VI carry out the United States obligations under the “Montreal Protocol on
Local Area Network Strategies and Guidelines for a Peruvian Air Force Computer Center
1991-03-01
service elements to support application processes such as job management, and financial data exchange. The layer also supports the virtual terminal and... virtual file concept. [Ref.3 :p. 285] Essentially, the lowest three layers are concerned with the communication protocols associated with the data...General de la Fuerza Aerea Peruana Lima, Republica del Peru 5. Escuela de Oficiales de la Fuerza Aerea Peruana 2 Biblioteca del Grupo del Instruccion Base
Secure Networks for First Responders and Special Forces
NASA Technical Reports Server (NTRS)
2005-01-01
When NASA needed help better securing its communications with orbiting satellites, the Agency called on Western DataCom Co., Inc., to help develop a prototype Internet Protocol (IP) router. Westlake, Ohio-based Western DataCom designs, develops, and manufactures hardware that secures voice, video, and data transmissions over any IP-based network. The technology that it jointly developed with NASA is now serving as a communications solution in military and first-response situations.
2012-09-01
reflect the official policy or position of the Department of Defense or the U.S. Government. IRB Protocol number ______N/A______. 12a. DISTRIBUTION...Warfare DHS Department of Homeland Security DoD Department of Defense DTMF Dual-Tone Multi-Frequency EOD Explosive Ordnance Disposal EU European...Organization JMTC Joint Multinational Training Command JTF Joint Task Force MANPADS Man Portable Air Defense Systems MERC Multilateral Export Control
A Fresh Look at Internet Protocol Version 6 (IPv6) for Department of Defense (DoD) Networks
2010-08-01
since system administration practices (such as the use of security appliances) depend heavily on tools for network management, diagnosis and protection...are mobile ad hoc networks (MANETs) and yet there is limited practical experience with MANETs and their performance. Further, the interaction between...Systems FCS Future Combat System IETF Internet Engineering Task Force ISAT Information Science and Technology BAST Board on Army Science and
1995-05-01
networks at thousands of sites in many countries and at thousands of business , government, research , and educational organizations. For many Internet users...medium of communications for academic and research and development communications. This is also true for a significant portion of the business ...thousands of business , government, research , and educational organizations. • The file transfer protocol, Gopher, Telnet, and the wide-area information
Chlordane in Air Force Family Housing: A Study of Houses Treated After Construction
1981-09-01
926-49-10?) 4. Tygon tubing 5. Slino psychrometer 6. Deionized water (for sling psychrometer ) 7. Wire clipper (for breaking ends off Chromosorb tubes...commander or environmental health officer with chlordane history and toxicoloay information. The Introduction section of this protocol can serve as a...will run for two hours. The scheduler should be well informed of the history , use and toxicolooy of chlordsne because the occupants will ask ouestions
Tees, D F; Waugh, R E; Hammer, D A
2001-01-01
A microcantilever technique was used to apply force to receptor-ligand molecules involved in leukocyte rolling on blood vessel walls. E-selectin was adsorbed onto 3-microm-diameter, 4-mm-long glass fibers, and the selectin ligand, sialyl Lewis(x), was coupled to latex microspheres. After binding, the microsphere and bound fiber were retracted using a computerized loading protocol that combines hydrodynamic and Hookean forces on the fiber to produce a range of force loading rates (force/time), r(f). From the distribution of forces at failure, the average force was determined and plotted as a function of ln r(f). The slope and intercept of the plot yield the unstressed reverse reaction rate, k(r)(o), and a parameter that describes the force dependence of reverse reaction rates, r(o). The ligand was titrated so adhesion occurred in approximately 30% of tests, implying that >80% of adhesive events involve single bonds. Monte Carlo simulations show that this level of multiple bonding has little effect on parameter estimation. The estimates are r(o) = 0.048 and 0.016 nm and k(r)(o) = 0.72 and 2.2 s(-1) for loading rates in the ranges 200-1000 and 1000-5000 pN s(-1), respectively. Levenberg-Marquardt fitting across all values of r(f) gives r(o) = 0.034 nm and k(r)(o) = 0.82 s(-1). The values of these parameters are in the range required for rolling, as suggested by adhesive dynamics simulations. PMID:11159435
Evaluation of prototype air/fluid separator for Space Station Freedom Health Maintenance Facility
NASA Technical Reports Server (NTRS)
Billica, Roger; Smith, Maureen; Murphy, Linda; Kizzee, Victor D.
1991-01-01
A prototype air/fluid separator suction apparatus proposed as a possible design for use with the Health Maintenance Facility aboard Space Station Freedom (SSF) was evaluated. A KC-135 parabolic flight test was performed for this purpose. The flights followed the standard 40 parabola profile with 20 to 25 seconds of near-zero gravity in each parabola. A protocol was prepared to evaluate the prototype device in several regulator modes (or suction force), using three fluids of varying viscosity, and using either continuous or intermittent suction. It was felt that a matrixed approach would best approximate the range of utilization anticipated for medical suction on SSF. The protocols were performed in one-gravity in a lab setting to familiarize the team with procedures and techniques. Identical steps were performed aboard the KC-135 during parabolic flight.
Preparation of swine for the laboratory.
Smith, Alison C; Swindle, M Michael
2006-01-01
Swine are an important model in many areas of biomedical research. These animals have been used predominantly as preclinical models involving surgical and interventional protocols. The systems most commonly studied include cardiovascular, integumentary, digestive, and urological. Swine are intelligent social animals and require species-specific socialization and handling techniques. It is important to acclimate the animals to the facility and to personnel before they are placed on chronic protocols. Gentle handling techniques instead of forceful procedures are essential to their socialization. They require sturdy caging with specific construction standards, and toys for environmental enrichment. Because the species is covered by both the Animal Welfare Act and the US Department of Agriculture, interstate transport requires a health certificate with destination state-specific disease screening standards. This manuscript provides an overview of best practices that have been utilized in the authors' facility.
Grigg, Nicole L; Wearing, Scott C; O'Toole, John M; Smeathers, James E
2014-01-01
To investigate the frequency characteristics of the ground reaction force (GRF) recorded throughout the eccentric Achilles tendon rehabilitation programme described by Alfredson. Controlled laboratory study, longitudinal. Nine healthy adult males performed six sets (15 repetitions per set) of eccentric ankle exercise. Ground reaction force was recorded throughout the exercise protocol. For each exercise repetition the frequency power spectrum of the resultant ground reaction force was calculated and normalised to total power. The magnitude of peak relative power within the 8-12 Hz bandwidth and the frequency at which this peak occurred was determined. The magnitude of peak relative power within the 8-12 Hz bandwidth increased with each successive exercise set and following the 4th set (60 repetitions) of exercise the frequency at which peak relative power occurred shifted from 9 to 10 Hz. The increase in magnitude and frequency of ground reaction force vibrations with an increasing number of exercise repetitions is likely connected to changes in muscle activation with fatigue and tendon conditioning. This research illustrates the potential for the number of exercise repetitions performed to influence the tendons' mechanical environment, with implications for tendon remodelling and the clinical efficacy of eccentric rehabilitation programmes for Achilles tendinopathy. Copyright © 2013 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.
Telezhkin, Vsevolod; Schnell, Christian; Yarova, Polina; Yung, Sun; Cope, Emma; Hughes, Alis; Thompson, Belinda A; Sanders, Philip; Geater, Charlene; Hancock, Jane M; Joy, Shona; Badder, Luned; Connor-Robson, Natalie; Comella, Andrea; Straccia, Marco; Bombau, Georgina; Brown, Jon T; Canals, Josep M; Randall, Andrew D; Allen, Nicholas D; Kemp, Paul J
2016-04-01
Although numerous protocols have been developed for differentiation of neurons from a variety of pluripotent stem cells, most have concentrated on being able to specify effectively appropriate neuronal subtypes and few have been designed to enhance or accelerate functional maturity. Of those that have, most employ time courses of functional maturation that are rather protracted, and none have fully characterized all aspects of neuronal function, from spontaneous action potential generation through to postsynaptic receptor maturation. Here, we describe a simple protocol that employs the sequential addition of just two supplemented media that have been formulated to separate the two key phases of neural differentiation, the neurogenesis and synaptogenesis, each characterized by different signaling requirements. Employing these media, this new protocol synchronized neurogenesis and enhanced the rate of maturation of pluripotent stem cell-derived neural precursors. Neurons differentiated using this protocol exhibited large cell capacitance with relatively hyperpolarized resting membrane potentials; moreover, they exhibited augmented: 1) spontaneous electrical activity; 2) regenerative induced action potential train activity; 3) Na(+) current availability, and 4) synaptic currents. This was accomplished by rapid and uniform development of a mature, inhibitory GABAAreceptor phenotype that was demonstrated by Ca(2+) imaging and the ability of GABAAreceptor blockers to evoke seizurogenic network activity in multielectrode array recordings. Furthermore, since this protocol can exploit expanded and frozen prepatterned neural progenitors to deliver mature neurons within 21 days, it is both scalable and transferable to high-throughput platforms for the use in functional screens. Copyright © 2016 the American Physiological Society.
Barber-Westin, Sue D; Noyes, Frank R
2017-12-01
Approximately two-thirds of anterior cruciate ligament (ACL) tears are sustained during noncontact situations when an athlete is cutting, pivoting, decelerating, or landing from a jump. Some investigators have postulated that fatigue may result in deleterious alterations in lower limb biomechanics during these activities that could increase the risk of noncontact ACL injuries. However, prior studies have noted a wide variation in fatigue protocols, athletic tasks studied, and effects of fatigue on lower limb kinetics and kinematics. First, to determine if fatigue uniformly alters lower limb biomechanics during athletic tasks that are associated with noncontact ACL injuries. Second, to determine if changes should be made in ACL injury prevention training programs to alter the deleterious effects of fatigue on lower limb kinetics and kinematics. Systematic review; Level of evidence, 4. A systematic review of the literature using MEDLINE was performed. Key terms were fatigue, neuromuscular, exercise, hop test, and single-legged function tests. Inclusion criteria were original research studies involving healthy participants, use of a fatigue protocol, study of at least 1 lower limb task that involved landing from a hop or jump or cutting, and analysis of at least 1 biomechanical variable. Thirty-seven studies involving 806 athletes (485 female, 321 male; mean age, 22.7 years) met the inclusion criteria. General fatigue protocols were used in 20 investigations, peripheral protocols were used in 17 studies, and 21 different athletic tasks were studied (13 single-legged, 8 double-legged). There was no consistency among investigations regarding the effects of fatigue on hip, knee, or ankle joint angles and moments or surface electromyography muscle activation patterns. The fatigue protocols typically did not produce statistically significant changes in ground-reaction forces. Published fatigue protocols did not uniformly produce alterations in lower limb neuromuscular factors that heighten the risk of noncontact ACL injuries. Therefore, justification does not currently exist for major changes in ACL injury prevention training programs to account for potential fatigue effects. However, the effect of fatigue related to ACL injuries is worthy of further investigation, including the refinement of protocols and methods of analysis.
Methacholine challenge testing: improved patient comfort with a 2-tiered protocol.
Segel, Michael J; Rabinovich, Einat; Schwarz, Yehuda; Ben-Dov, Issahar
2013-06-01
The methacholine challenge test (MCT) is a test of bronchial hyperreactivity used as an aid in the diagnosis of asthma. MCT results are reported as the provocation concentration at which the forced expiratory volume in 1 second (FEV1) decreases 20% (PC20). The requirement for a 20% or greater decrease in FEV1 results in precipitous decreases in FEV1 in some patients. To improve MCT safety without compromising accuracy. We performed a retrospective analysis of 879 consecutive MCTs (derivation cohort). A novel protocol for MCT was developed and validated in a cohort of 564 MCTs performed in a second institution. In comparison with a PC20 cutoff of less than 8 mg/mL, a provocation concentration at which the FEV1 decreases 10% (PC10) cutoff of 1 mg/mL or less has a sensitivity of 86%, a specificity of 98%, a positive predictive value (PPV) of 97%, and a negative predictive value (NPV) of 91%. We propose a novel 2-tiered protocol for MCT. If the PC10 is 1 mg/mL or less, bronchial hyperreactivity is present; if the PC10 is greater than 1 mg/mL, the test is continued until the provocative concentration is 8 mg/mL or a 20% decrease in FEV1 is achieved. Compared with the standard protocol, the proposed protocol has a sensitivity, specificity, PPV, NPV, and overall accuracy of 100%, 98%, 97.6%, 100%, and 99%, respectively. The modified protocol would have enabled us to avoid 26 of 42 cases (62%) in which a 40% or greater decrease in FEV1 occurred and would save 0.65 dose for every MCT performed. The 2-tiered protocol performed well in the validation cohort; sensitivity, specificity, PPV, NPV, and overall accuracy were 100%, 98%, 87%, 100%, and 98%, respectively. The proposed 2-tiered protocol is accurate, saves time, and avoids precipitous decreases in FEV1. Copyright © 2013 American College of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.
Effects of quadriceps strength after static and dynamic whole-body vibration exercise.
Bush, Jill A; Blog, Gabriel L; Kang, Jie; Faigenbaum, Avery D; Ratamess, Nicholas A
2015-05-01
Numerous studies have shown performance benefits including whole-body vibration (WBV) as a training modality or an acute exercise protocol when used as a component of the resistance training program. Some studies have indicated that performing dynamic exercises as compared with static position exercises while exposed to WBV might be beneficial; however, evidence is lacking. Thus, the purpose of this study was to determine if an acute bout of dynamic versus static squats performed during WBV results in increase in quadriceps force production by means of dynamic isokinetic knee extension and flexion exercise. Nonresistance-trained healthy young men and women (N = 21) of 18-25 years participated in 4 protocols with 2-week rest in-between. Protocol 1 consisted of 5 sets of 10 dynamic squats without vibration; Protocol 2: 5 sets of 30-second static squats without vibration; Protocol 3: 5 sets of 10 dynamic squats with 30-Hz WBV for a total of 2.5 minutes; and Protocol 4: 5 sets of 30-second static squats with 30-Hz WBV for a total of 2.5 minutes. Prestrength tests (1 set of 4 repetitions at 100° · s(-1) for the knee extension exercise) was performed within 5 minutes of starting each protocol, and poststrength testing was performed within 1 minute of completing each protocol. Strength outcomes were analyzed by repeated measures analysis of variance with a significance level set at p ≤ 0.05. A significant decrease in strength was observed after dynamic and static squats without WBV (p = 0.002); an increase in strength after dynamic squats with WBV (p = 0.003); and a decrease in strength after static squats with WBV (p = 0.003). The inclusion of WBV to dynamic resistance exercise can be an added modality to increase strength. Whole-body vibration can have varied effects in altering muscle strength in untrained individuals according to the type of resistance training performed. As a dynamic squat with WBV seems to immediately potentiate neuromuscular functioning, the combination of dynamic exercises and WBV could be used as a potential warm-up procedure before resistance exercise.
Neuromuscular Fatigue and Physiological Responses After Five Dynamic Squat Exercise Protocols.
Raeder, Christian; Wiewelhove, Thimo; Westphal-Martinez, Marc P; Fernandez-Fernandez, Jaime; de Paula Simola, Rauno A; Kellmann, Michael; Meyer, Tim; Pfeiffer, Mark; Ferrauti, Alexander
2016-04-01
This aimed to analyze neuromuscular, physiological and perceptual responses to a single bout of 5 different dynamic squat exercise protocols. In a randomized and counterbalanced order, 15 male resistance-trained athletes (mean ± SD; age: 23.1 ± 1.9 years, body mass: 77.4 ± 8.0 kg) completed traditional multiple sets (MS: 4 × 6, 85% 1 repetition maximum [RM]), drop sets (DS: 1 × 6, 85% 1RM + 3 drop sets), eccentric overload (EO: 4 × 6, 70% 1RM concentric, 100% 1RM eccentric), flywheel YoYo squat (FW: 4 × 6, all-out), and a plyometric jump protocol (PJ: 4 × 15, all-out). Blood lactate (La), ratings of perceived exertion (RPE), counter movement jump height (CMJ), multiple rebound jump (MRJ) performance, maximal voluntary isometric contraction force, serum creatine kinase (CK) and delayed onset muscle soreness were measured. Immediately post exercise, La was significantly (p < 0.001) higher in FW (mean ± 95% confidence limit; 12.2 ± 0.9 mmol·L) and lower in PJ (3.0 ± 0.8 mmol·L) compared with MS (7.7 ± 1.5 mmol·L), DS (8.5 ± 0.6 mmol·L), and EO (8.2 ± 1.6 mmol·L), accompanied by similar RPE responses. Neuromuscular performance (CMJ, MRJ) significantly remained decreased (p < 0.001) from 0.5 to 48 hours post exercise in all protocols. There was a significant time × protocol interaction (p ≤ 0.05) in MRJ with a significant lower performance in DS, EO, and FW compared with PJ (0.5 hours post exercise), and in EO compared with all other protocols (24 hours post exercise). A significant main time effect with peak values 24 hours post exercise was observed in CK serum concentrations (p < 0.001), but there was no time × protocol interaction. In conclusion, (a) metabolic and perceptual demands were higher in FW and EO compared with MS, DS and PJ, (b) neuromuscular fatigue was consistent up to 48 hours post exercise in all protocols, and (c) EO induced the greatest neuromuscular fatigue.
Francisconi, Manoela Fávaro; Janson, Guilherme; Henriques, José Fernando Castanha; Freitas, Karina Maria Salvatore de
2016-01-01
The purpose of this study was to evaluate the deflection forces of Nitinol orthodontic wires placed in different types of brackets: metallic, reinforced polycarbonate with metallic slots, sapphire, passive and active self-ligating, by assessing strength values variation according to gradual increase in wire diameter and deflection and comparing different combinations in the different deflections. Specimens were set in a clinical simulation model and evaluated in a Universal Testing Machine (INSTRON 3342), using the ISO 15841 protocol. Data were subjected to One-way ANOVA, followed by Tukey tests (p<0.05). Self-ligating brackets presented the most similar behavior to each other. For conventional brackets there was no consistent behavior for any of the deflections studied. Self-ligating brackets presented the most consistent and predictable results while conventional brackets, as esthetic brackets, showed very different patterns of forces. Self-ligating brackets showed higher strength in all deflections when compared with the others, in 0.020-inch wires.
Effect of toe extension on EMG of triceps surae muscles during isometric dorsiflexion.
Siddiqi, Ariba; Arjunan, Sridhar P; Kumar, Dinesh
2016-12-01
The protocol for estimating force of contraction by triceps surae (TS) muscles requires the immobilization of the ankle during dorsiflexion and plantar flexion. However, large variability in the results has been observed. To identify the cause of this variability, experiments were conducted where ankle dorsiflexion force and electromyogram (EMG) of the TS were recorded under two conditions: (i) toes were strapped and (ii) toes were unstrapped, with all other conditions such as immobilization of the ankle remaining unchanged. The root mean square (RMS) of the EMG and the force were analyzed and one-tail Student's t-test was performed for significance between the two conditions. The RMS of the EMG from TS muscles was found to be significantly higher (~55%) during dorsiflexion with toes unstrapped compared with when the toes were strapped. The torque corresponding to dorsiflexion was also higher with toes unstrapped. Our study has shown that it is important to strap the toes when measuring the torque at the ankle and EMG of the TS muscles.
Morel, B; Hautier, C A
2017-02-01
The aim of this study was to evaluate the influence of the fatigue on the machine scrum pushing sagittal forces during repeated scrums and to determine the origin of the knee extensor fatigue. Twelve elite U23 rugby union front row players performed six 6-s scrums every 30 s against a dynamic scrum machine with passive or active recovery. The peak, average, and the standard deviation of the force were measured. A neuromuscular testing procedure of the knee extensors was carried out before and immediately after the repeated scrum protocol including maximal voluntary force, evoked force, and voluntary activation. The average and peak forces did not decrease after six scrums with passive recovery. The standard deviation of the force increased by 70.2 ± 42.7% (P < 0.001). Maximal voluntary/evoked force and voluntary activation decreased (respectively 25.1 ± 7.0%, 14.6 ± 5.5%, and 24 ± 9.9%; P < 0.001). The standard deviation of the force did not increase with active recovery and was associated with lower decrease of maximal voluntary/evoked force and voluntary activation (respectively 12.8 ± 7.9%, 4.9 ± 6.5%, and 7.6 ± 4.1%; all P < 0.01). As a conclusion repeated scrummaging induced an increased machine scrum pushing instability associated with central and peripheral fatigue of the knee extensors. Active recovery seems to limit all these manifestations of fatigue. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Mammographic compression in Asian women.
Lau, Susie; Abdul Aziz, Yang Faridah; Ng, Kwan Hoong
2017-01-01
To investigate: (1) the variability of mammographic compression parameters amongst Asian women; and (2) the effects of reducing compression force on image quality and mean glandular dose (MGD) in Asian women based on phantom study. We retrospectively collected 15818 raw digital mammograms from 3772 Asian women aged 35-80 years who underwent screening or diagnostic mammography between Jan 2012 and Dec 2014 at our center. The mammograms were processed using a volumetric breast density (VBD) measurement software (Volpara) to assess compression force, compression pressure, compressed breast thickness (CBT), breast volume, VBD and MGD against breast contact area. The effects of reducing compression force on image quality and MGD were also evaluated based on measurement obtained from 105 Asian women, as well as using the RMI156 Mammographic Accreditation Phantom and polymethyl methacrylate (PMMA) slabs. Compression force, compression pressure, CBT, breast volume, VBD and MGD correlated significantly with breast contact area (p<0.0001). Compression parameters including compression force, compression pressure, CBT and breast contact area were widely variable between [relative standard deviation (RSD)≥21.0%] and within (p<0.0001) Asian women. The median compression force should be about 8.1 daN compared to the current 12.0 daN. Decreasing compression force from 12.0 daN to 9.0 daN increased CBT by 3.3±1.4 mm, MGD by 6.2-11.0%, and caused no significant effects on image quality (p>0.05). Force-standardized protocol led to widely variable compression parameters in Asian women. Based on phantom study, it is feasible to reduce compression force up to 32.5% with minimal effects on image quality and MGD.
Engkvist, I L; Hagberg, M; Wigaeus-Hjelm, E; Menckel, E; Ekenvall, L
1995-06-01
No documented strategy, including preventive strategies, for systematic investigation of overexertion back accidents among nursing personnel has yet been published. One aim of the present study was to develop standardized instruments for the systematic investigation of back accidents among nursing personnel in order to develop preventive strategies. Another aim was to produce a screening tool that could easily be used for identifying potential overexertion back accident hazards. Two structured interview protocols were developed, one for the injured person and one for the supervisor. An ergonomics checklist was designed for the most important spaces according to accident statistics: patient's room, corridor, toilet, and also one for 'other space', eg X-ray and treatment rooms. The instruments were developed by frequent discussions and adjustments in a task force of researchers and occupational health personnel. The protocols were tested in two steps before a final version was established. The construct validity and interobserver reliability of the checklist were tested by ten ergonomists, who checked a patient's room, a toilet and a corridor with some known hazards. The constructed validity agreement was 90% in 19 of 26 items in the checklist. The interobserver reliability had the same figures as the validity for all items in the checklist. The interview protocols and checklist appear to be suitable for systematic investigation of overexertion back accidents.
NASA Astrophysics Data System (ADS)
Garai, Ashok; Mogurampelly, Santosh; Bag, Saientan; Maiti, Prabal K.
2017-12-01
We report a structural polymorphism of the S-DNA when a canonical B-DNA is stretched under different pulling protocols and provide a fundamental molecular understanding of the DNA stretching mechanism. Extensive all atom molecular dynamics simulations reveal a clear formation of S-DNA when the B-DNA is stretched along the 3' directions of the opposite strands (OS3) and is characterized by the changes in the number of H-bonds, entropy, and free energy. Stretching along the 5' directions of the opposite strands (OS5) leads to force induced melting form of the DNA. Interestingly, stretching along the opposite ends of the same strand leads to a coexistence of both the S- and melted M-DNA structures. We also do the structural characterization of the S-DNA by calculating various helical parameters. We find that the S-DNA has a twist of ˜10° which corresponds to a helical repeat length of ˜36 base pairs in close agreement with the previous experimental results. Moreover, we find that the free energy barrier between the canonical and overstretched states of DNA is higher for the same termini pulling protocol in comparison to all other protocols considered in this work. Overall, our observations not only reconcile with the available experimental results qualitatively but also enhance the understanding of different overstretched DNA structures.
Human seasonal and circadian studies in Antarctica (Halley, 75°S).
Arendt, Josephine; Middleton, Benita
2018-03-01
Living for extended periods in Antarctica exposes base personnel to extremes of daylength (photoperiod) and temperature. At the British Antarctic Survey base of Halley, 75°S, the sun does not rise for 110 d in the winter and does not set for 100 d in summer. Photoperiod is the major time cue governing the timing of seasonal events such as reproduction in many species. The neuroendocrine signal providing photoperiodic information to body physiology is the duration of melatonin secretion which reflects the length of the night: longer in the short days of winter and shorter in summer. Light of sufficient intensity and spectral composition serves to suppress production of melatonin and to set the circadian timing and the duration of the rhythm. In humans early observations suggested that bright (>2000 lux) white light was needed to suppress melatonin completely. Shortly thereafter winter depression (Seasonal Affective Disorder or SAD) was described, and its successful treatment by an artificial summer photoperiod of bright white light, sufficient to shorten melatonin production. At Halley dim artificial light intensity during winter was measured, until 2003, at a maximum of approximately 500 lux in winter. Thus a strong seasonal and circadian time cue was absent. It seemed likely that winter depression would be common in the extended period of winter darkness and could be treated with an artificial summer photoperiod. These observations, and predictions, inspired a long series of studies regarding human seasonal and circadian status, and the effects of light treatment, in a small overwintering, isolated community, living in the same conditions for many months at Halley. We found little evidence of SAD, or change in duration of melatonin production with season. However the timing of the melatonin rhythm itself, and/or that of its metabolite 6-sulphatoxymelatonin (aMT6s), was used as a primary marker of seasonal, circadian and treatment changes. A substantial phase delay of melatonin in winter was advanced to summer phase by a two pulse 'skeleton' bright white light treatment. Subsequently a single morning pulse of bright white light was effective with regard to circadian phase and improved daytime performance. The circadian delay evidenced by melatonin was accompanied by delayed sleep (logs and actigraphy): poor sleep is a common complaint in Polar regions. Appropriate extra artificial light, both standard white, and blue enriched, present throughout the day, effectively countered delay in sleep timing and the aMT6s rhythm. The most important factor appeared to be the maximum light experienced. Another manifestation of the winter was a decline in self-rated libido (men only on base at this time). Women on the base showed lower aspects of physical and mental health compared to men. Free-running rhythms were seen in some subjects following night shift, but were rarely found at other times, probably because this base has strongly scheduled activity and leisure time. Complete circadian adaptation during a week of night shift, also seen in a similar situation on North Sea oil rigs, led to problems readapting back to day shift in winter, compared to summer. Here again timed light treatment was used to address the problem. Sleep, alertness and waking performance are critically dependent on optimum circadian phase. Circadian desynchrony is associated with increased risk of major disease in shift workers. These studies provide some groundwork for countering/avoiding circadian desynchrony in rather extreme conditions. Copyright © 2017 Elsevier Inc. All rights reserved.
Analog Exercise Hardware to Implement a High Intensity Exercise Program During Bed Rest
NASA Technical Reports Server (NTRS)
Loerch, Linda; Newby, Nate; Ploutz-Snyder, Lori
2012-01-01
Background: In order to evaluate novel countermeasure protocols in a space flight analog prior to validation on the International Space Station (ISS), NASA's Human Research Program (HRP) is sponsoring a multi-investigator bedrest campaign that utilizes a combination of commercial and custom-made exercise training hardware to conduct daily resistive and aerobic exercise protocols. This paper will describe these pieces of hardware and how they are used to support current bedrest studies at NASA's Flight Analog Research Unit in Galveston, TX. Discussion: To implement candidate exercise countermeasure studies during extended bed rest studies the following analog hardware are being utilized: Stand alone Zero-Gravity Locomotion Simulator (sZLS) -- a custom built device by NASA, the sZLS allows bedrest subjects to remain supine as they run on a vertically-oriented treadmill (0-15 miles/hour). The treadmill includes a pneumatic subject loading device to provide variable body loading (0-100%) and a harness to keep the subject in contact with the motorized treadmill to provide a ground reaction force at their feet that is quantified by a Kistler Force Plate. Supine Cycle Ergometer -- a commercially available supine cycle ergometer (Lode, Groningen, Netherlands) is used for all cycle ergometer sessions. The ergometer has adjustable shoulder supports and handgrips to help stabilize the subject during exercise. Horizontal Squat Device (HSD) -- a custom built device by Quantum Fitness Corp (Stafford, TX), the HSD allows for squat exercises to be performed while lying in a supine position. The HSD can provide 0 to 600 pounds of force in selectable 5 lb increments, and allows hip translation in both the vertical and horizontal planes. Prone Leg Curl -- a commercially available prone leg curl machine (Cybex International Inc., Medway, MA) is used to complete leg curl exercises. Horizontal Leg Press -- a commercially available horizontal leg press (Quantum Fitness Corporation) is used for leg press and heel raise exercises. Minor modifications were made to the device including adding 200 lbs to the weight stack, raising the frame by 12 inches, making the footplate adjustable, and providing removable handles. Conclusion: A combination of novel and commercial exercise hardware are used to mimic the exercise hardware capabilities aboard the ISS, allowing scientific investigation of new countermeasure protocols in a space flight analog prior to flight validation
Legal considerations during pediatric emergency mass critical care events.
Courtney, Brooke; Hodge, James G
2011-11-01
Recent public health emergencies, such as the 2009 Influenza A/H1N1 Pandemic and Hurricane Katrina, underscore the importance of developing healthcare response plans and protocols for disasters impacting large populations. Significant research and scholarship, including the 2009 Institute of Medicine report on crisis standards of care and the 2008 Task Force for Mass Critical Care recommendations, provide guidance for healthcare responses to catastrophic emergencies. Most of these efforts recognize but do not focus on the unique needs of pediatric populations. In 2008, the Centers for Disease Control and Prevention supported the formation of a task force to address pediatric emergency mass critical care response issues, including legal issues. Liability is a significant concern for healthcare practitioners and facilities during pediatric emergency mass critical care that necessitates a shift to crisis standards of care. This article describes the legal considerations inherent in planning for and responding to catastrophic health emergencies and makes recommendations for pediatric emergency mass critical care legal preparedness. The Pediatric Emergency Mass Critical Care Task Force, composed of 36 experts from diverse public health, medical, and disaster response fields, convened in Atlanta, GA, on March 29-30, 2010, to review the pediatric emergency mass critical care recommendations developed by a 17-member steering committee. During the meeting, experts determined that the recommendations would be strengthened by a manuscript addressing legal issues. Authors drafted the manuscript through consensus-based study of peer-reviewed research, literature reviews, and expert opinion. The manuscript was reviewed by Pediatric Emergency Mass Critical Care Steering Committee members and additional legal counsel and revised. While the legal issues associated with providing pediatric emergency mass critical care are not unique within the overall context of disaster healthcare, the scope of the parens patriae power of states, informed consent principles, and security should be considered in pediatric emergency mass critical care planning and response efforts because parents and legal guardians may be unavailable to participate in healthcare decision making during disasters. In addition, practitioners who follow properly vetted and accepted pediatric emergency mass critical care disaster protocols in good faith should be protected from civil liability, and healthcare facilities that provide pediatric care should incorporate informed consent and security protocols into their disaster plans.
Potentials of Mean Force With Ab Initio Mixed Hamiltonian Models of Solvation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dupuis, Michel; Schenter, Gregory K.; Garrett, Bruce C.
2003-08-01
We give an account of a computationally tractable and efficient procedure for the calculation of potentials of mean force using mixed Hamiltonian models of electronic structure where quantum subsystems are described with computationally intensive ab initio wavefunctions. The mixed Hamiltonian is mapped into an all-classical Hamiltonian that is amenable to a thermodynamic perturbation treatment for the calculation of free energies. A small number of statistically uncorrelated (solute-solvent) configurations are selected from the Monte Carlo random walk generated with the all-classical Hamiltonian approximation. Those are used in the averaging of the free energy using the mixed quantum/classical Hamiltonian. The methodology ismore » illustrated for the micro-solvated SN2 substitution reaction of methyl chloride by hydroxide. We also compare the potential of mean force calculated with the above protocol with an approximate formalism, one in which the potential of mean force calculated with the all-classical Hamiltonian is simply added to the energy of the isolated (non-solvated) solute along the reaction path. Interestingly the latter approach is found to be in semi-quantitative agreement with the full mixed Hamiltonian approximation.« less
Links between the charge model and bonded parameter force constants in biomolecular force fields
NASA Astrophysics Data System (ADS)
Cerutti, David S.; Debiec, Karl T.; Case, David A.; Chong, Lillian T.
2017-10-01
The ff15ipq protein force field is a fixed charge model built by automated tools based on the two charge sets of the implicitly polarized charge method: one set (appropriate for vacuum) for deriving bonded parameters and the other (appropriate for aqueous solution) for running simulations. The duality is intended to treat water-induced electronic polarization with an understanding that fitting data for bonded parameters will come from quantum mechanical calculations in the gas phase. In this study, we compare ff15ipq to two alternatives produced with the same fitting software and a further expanded data set but following more conventional methods for tailoring bonded parameters (harmonic angle terms and torsion potentials) to the charge model. First, ff15ipq-Qsolv derives bonded parameters in the context of the ff15ipq solution phase charge set. Second, ff15ipq-Vac takes ff15ipq's bonded parameters and runs simulations with the vacuum phase charge set used to derive those parameters. The IPolQ charge model and associated protocol for deriving bonded parameters are shown to be an incremental improvement over protocols that do not account for the material phases of each source of their fitting data. Both force fields incorporating the polarized charge set depict stable globular proteins and have varying degrees of success modeling the metastability of short (5-19 residues) peptides. In this particular case, ff15ipq-Qsolv increases stability in a number of α -helices, correctly obtaining 70% helical character in the K19 system at 275 K and showing appropriately diminishing content up to 325 K, but overestimating the helical fraction of AAQAA3 by 50% or more, forming long-lived α -helices in simulations of a β -hairpin, and increasing the likelihood that the disordered p53 N-terminal peptide will also form a helix. This may indicate a systematic bias imparted by the ff15ipq-Qsolv parameter development strategy, which has the hallmarks of strategies used to develop other popular force fields, and may explain some of the need for manual corrections in this force fields' evolution. In contrast, ff15ipq-Vac incorrectly depicts globular protein unfolding in numerous systems tested, including Trp cage, villin, lysozyme, and GB3, and does not perform any better than ff15ipq or ff15ipq-Qsolv in tests on short peptides. We analyze the free energy surfaces of individual amino acid dipeptides and the electrostatic potential energy surfaces of each charge model to explain the differences.
Direct measurement of a nonequilibrium system entropy using a feedback trap
NASA Astrophysics Data System (ADS)
Gavrilov, Momčilo; Bechhoefer, John
2017-08-01
Feedback traps are tools for trapping single charged objects in solution. They periodically measure an object's position and apply a feedback force to counteract Brownian motion. The feedback force can be calculated as a gradient of a potential function, effectively creating a "virtual potential." Its flexibility regarding the choice of form of the potential gives an opportunity to explore various fundamental questions in stochastic thermodynamics. Here, we review the theory behind feedback traps and apply it to measuring the average work required to erase a fraction of a bit of information. The results agree with predictions based on the nonequilibrium system entropy. With this example, we also show how a feedback trap can easily implement the complex erasure protocols required to reach ultimate thermodynamic limits.
Adsorption orientations and immunological recognition of antibodies on graphene
NASA Astrophysics Data System (ADS)
Vilhena, J. G.; Dumitru, A. C.; Herruzo, Elena T.; Mendieta-Moreno, Jesús I.; Garcia, Ricardo; Serena, P. A.; Pérez, Rubén
2016-07-01
Large-scale molecular dynamics (MD) simulations and atomic force microscopy (AFM) in liquid are combined to characterize the adsorption of Immunoglobulin G (IgG) antibodies over a hydrophobic surface modeled with a three-layer graphene slab. We consider explicitly the water solvent, simulating systems with massive sizes (up to 770 000 atoms), for four different adsorption orientations. Protocols based on steered MD to speed up the protein diffusion stage and to enhance the dehydration process are combined with long simulation times (>150 ns) in order to make sure that the final adsorption states correspond to actual stable configurations. Our MD results and the AFM images demonstrate that the IgG antibodies are strongly adsorbed, do not unfold, and retain their secondary and tertiary structures upon deposition. Statistical analysis of the AFM images shows that many of the antibodies adopt vertical orientations, even at very small coverages, which expose at least one Fab binding site for recognition events. Single molecule force spectroscopy experiments demonstrate the immunological response of the deposited antibodies by recognizing its specific antigens. The above properties together with the strong anchoring and preservation of the secondary structure, make graphene an excellent candidate for the development of immunosensors.Large-scale molecular dynamics (MD) simulations and atomic force microscopy (AFM) in liquid are combined to characterize the adsorption of Immunoglobulin G (IgG) antibodies over a hydrophobic surface modeled with a three-layer graphene slab. We consider explicitly the water solvent, simulating systems with massive sizes (up to 770 000 atoms), for four different adsorption orientations. Protocols based on steered MD to speed up the protein diffusion stage and to enhance the dehydration process are combined with long simulation times (>150 ns) in order to make sure that the final adsorption states correspond to actual stable configurations. Our MD results and the AFM images demonstrate that the IgG antibodies are strongly adsorbed, do not unfold, and retain their secondary and tertiary structures upon deposition. Statistical analysis of the AFM images shows that many of the antibodies adopt vertical orientations, even at very small coverages, which expose at least one Fab binding site for recognition events. Single molecule force spectroscopy experiments demonstrate the immunological response of the deposited antibodies by recognizing its specific antigens. The above properties together with the strong anchoring and preservation of the secondary structure, make graphene an excellent candidate for the development of immunosensors. Electronic supplementary information (ESI) available: Further details concerning the experimental methods, the MD simulation protocols, and the characterization and stability of the different adsorption configurations. See DOI: 10.1039/C5NR07612A
Bochkezanian, Vanesa; Newton, Robert U; Trajano, Gabriel S; Vieira, Amilton; Pulverenti, Timothy S; Blazevich, Anthony J
2018-02-13
Neuromuscular electrical stimulation (NMES) is commonly used in skeletal muscles in people with spinal cord injury (SCI) with the aim of increasing muscle recruitment and thus muscle force production. NMES has been conventionally used in clinical practice as functional electrical stimulation (FES), using low levels of evoked force that cannot optimally stimulate muscular strength and mass improvements, and thus trigger musculoskeletal changes in paralysed muscles. The use of high intensity intermittent NMES training using wide-pulse width and moderate-intensity as a strength training tool could be a promising method to increase muscle force production in people with SCI. However, this type of protocol has not been clinically adopted because it may generate rapid muscle fatigue and thus prevent the performance of repeated high-intensity muscular contractions in paralysed muscles. Moreover, superimposing patellar tendon vibration onto the wide-pulse width NMES has been shown to elicit further increases in impulse or, at least, reduce the rate of fatigue in repeated contractions in able-bodied populations, but there is a lack of evidence to support this argument in people with SCI. Nine people with SCI received two NMES protocols with and without superimposing patellar tendon vibration on different days (i.e. STIM and STIM+vib), which consisted of repeated 30 Hz trains of 58 wide-pulse width (1000 μs) symmetric biphasic pulses (0.033-s inter-pulse interval; 2 s stimulation train; 2-s inter-train interval) being delivered to the dominant quadriceps femoris. Starting torque was 20% of maximal doublet-twitch torque and stimulations continued until torque declined to 50% of the starting torque. Total knee extensor impulse was calculated as the primary outcome variable. Total knee extensor impulse increased in four subjects when patellar tendon vibration was imposed (59.2 ± 15.8%) but decreased in five subjects (- 31.3 ± 25.7%). However, there were no statistically significant differences between these sub-groups or between conditions when the data were pooled. Based on the present results there is insufficient evidence to conclude that patellar tendon vibration provides a clear benefit to muscle force production or delays muscle fatigue during wide-pulse width, moderate-intensity NMES in people with SCI. ACTRN12618000022268 . Date: 11/01/2018. Retrospectively registered.
Masia, Lorenzo; Frascarelli, Flaminia; Morasso, Pietro; Di Rosa, Giuseppe; Petrarca, Maurizio; Castelli, Enrico; Cappa, Paolo
2011-05-21
It is known that healthy adults can quickly adapt to a novel dynamic environment, generated by a robotic manipulandum as a structured disturbing force field. We suggest that it may be of clinical interest to evaluate to which extent this kind of motor learning capability is impaired in children affected by cerebal palsy. We adapted the protocol already used with adults, which employs a velocity dependant viscous field, and compared the performance of a group of subjects affected by Cerebral Palsy (CP group, 7 subjects) with a Control group of unimpaired age-matched children. The protocol included a familiarization phase (FA), during which no force was applied, a force field adaptation phase (CF), and a wash-out phase (WO) in which the field was removed. During the CF phase the field was shut down in a number of randomly selected "catch" trials, which were used in order to evaluate the "learning index" for each single subject and the two groups. Lateral deviation, speed and acceleration peaks and average speed were evaluated for each trajectory; a directional analysis was performed in order to inspect the role of the limb's inertial anisotropy in the different experimental phases. During the FA phase the movements of the CP subjects were more curved, displaying greater and variable directional error; over the course of the CF phase both groups showed a decreasing trend in the lateral error and an after-effect at the beginning of the wash-out, but the CP group had a non significant adaptation rate and a lower learning index, suggesting that CP subjects have reduced ability to learn to compensate external force. Moreover, a directional analysis of trajectories confirms that the control group is able to better predict the force field by tuning the kinematic features of the movements along different directions in order to account for the inertial anisotropy of arm. Spatial abnormalities in children affected by cerebral palsy may be related not only to disturbance in motor control signals generating weakness and spasticity, but also to an inefficient control strategy which is not based on a robust knowledge of the dynamical features of their upper limb. This lack of information could be related to the congenital nature of the brain damage and may contribute to a better delineation of therapeutic intervention.
Technical Report: A Review of Groupware Technologies
1996-05-21
about $3 of software, according to Lill.‘= Other video products, such as the popular CU- SeeMe application, use their own protocols, but their vendors...offering help to users in getting it up and running. ** CU- SeeMe is a very cost-effective solution when sharp images and 30 frames per second are not...essential. CU- SeeMe was used by sailors of the Antarctic Development Squadron (VXE) 6 and U.S. Naval Support Force, Antarctica to communicate with
Cadmium Alternatives for High-Strength Steel JTP - Phase 2
2008-02-27
Project Overview Objective • Assess DoD- selected Cadmium alternatives in accordance with the DoD-approved Joint Test Protocol (JTP) for both...HE and adhesion testing): NAVAIR (complete) – Phase II (JTP test matrix): AFRL/CTC – Phase III (Testing for Threaded Fasteners): ARL • Selection of...Curry • Hill AFB – Mr. Nate Hughes • Alumiplate – Mr. Gus Vallejo • Marshall Labs – Mr. John Marshall U.S. AIR FORCE Phase I Overview and Selection
2010-06-25
Deputy, 711 HPW/XP), Roscoe "Yogi" VanCamp,UCa!. USAF, and Mark Marley, M.A., (project manager ) who were critical to the logistical operations of...national security, and international relations. Understanding basic principles of aviation, crew resource management , communicat ion protocols, geo...ain::raft flight controls, instruments, weight, balance), as well as topics in aircrew coordination (e.g., crew resource management and situational
1982-12-01
the use of combinational and correlational analysis, statements about the prohability of a disease state, a subclinical state, * and/or over-reporting...phyria cutanea tarda and hypothyroidism have also been linked to 2,4,5-T/TCDD exposure. Other symptoms such as asthenia, liver and renal dysfunction...decrease in the prevalence and severity of chloracne in the exposed population; (2) an increase in clinical and subclinical neurologic disease as
2016-03-01
or position of the Department of Defense or the U.S. Government . IRB Protocol number ____N/A____. 12a. DISTRIBUTION / AVAILABILITY STATEMENT Approved...used by those who enter the country with minimal or delayed government screening and those who enter the country with no government screening...federal government that is designed to assist international populations with the greatest migratory need: forced migrants, refugees and asylum
The biomarker-based diagnosis of Alzheimer's disease. 1-ethical and societal issues.
Porteri, Corinna; Albanese, Emiliano; Scerri, Charles; Carrillo, Maria C; Snyder, Heather M; Martensson, Birgitta; Baker, Mark; Giacobini, Ezio; Boccardi, Marina; Winblad, Bengt; Frisoni, Giovanni B; Hurst, Samia
2017-04-01
There is great interest in the use of biomarkers to assist in the timely identification of Alzheimer's disease (AD) in individuals with mild symptoms. However, the inclusion of AD biomarkers in clinical criteria poses socioethical challenges. The Geneva Task Force for the Roadmap of Alzheimer's Biomarkers was established to deliver a systematic strategic research agenda (aka roadmap) to promote efficient and effective validation of AD biomarkers and to foster their uptake in clinical practice. In this article, we summarize the workshop discussion of the Geneva Task Force "ethical and societal issues" working group, which comprised bioethicists, clinicians, health economists, and representatives of those affected by AD. The working group identified the following key issues that need to be included in the roadmap: improving access to services through timely diagnosis, the need for a diagnostic research protocol before moving to clinical routine, recruitment in diagnostic research protocols in the absence of effective therapy, respect for the autonomy of the individual with mild cognitive impairment in information and consent process and the right not to know biomarkers results, need for counseling programs, disclosure of the diagnosis in a structured environment and the involvement of family members, health policies including the individuals' views and the protection of their interests, and the economic costs for society. Copyright © 2016 Elsevier Inc. All rights reserved.
Dao, Tien Tuan; Pouletaut, Philippe; Charleux, Fabrice; Tho, Marie-Christine Ho Ba; Bensamoun, Sabine
2014-01-01
The purpose of this study was to develop a subject specific finite element model derived from MRI images to numerically analyze the MRE (magnetic resonance elastography) shear wave propagation within skeletal thigh muscles. A sagittal T2 CUBE MRI sequence was performed on the 20-cm thigh segment of a healthy male subject. Skin, adipose tissue, femoral bone and 11 muscles were manually segmented in order to have 3D smoothed solid and meshed models. These tissues were modeled with different constitutive laws. A transient modal dynamics analysis was applied to simulate the shear wave propagation within the thigh tissues. The effects of MRE experimental parameters (frequency, force) and the muscle material properties (shear modulus: C10) were analyzed through the simulated shear wave displacement within the vastus medialis muscle. The results showed a plausible range of frequencies (from 90Hz to 120 Hz), which could be used for MRE muscle protocol. The wave amplitude increased with the level of the force, revealing the importance of the boundary condition. Moreover, different shear displacement patterns were obtained as a function of the muscle mechanical properties. The present study is the first to analyze the shear wave propagation in skeletal muscles using a 3D subject specific finite element model. This study could be of great value to assist the experimenters in the set-up of MRE protocols.
Agmatine attenuates chronic unpredictable mild stress induced behavioral alteration in mice.
Taksande, Brijesh G; Faldu, Dharmesh S; Dixit, Madhura P; Sakaria, Jay N; Aglawe, Manish M; Umekar, Milind J; Kotagale, Nandkishor R
2013-11-15
Chronic stress exposure and resulting dysregulation of the hypothalamic pituitary adrenal axis develops susceptibility to variety of neurological and psychiatric disorders. Agmatine, a putative neurotransmitter has been reported to be released in response to various stressful stimuli to maintain the homeostasis. Present study investigated the role of agmatine on chronic unpredictable mild stress (CUMS) induced behavioral and biochemical alteration in mice. Exposure of mice to CUMS protocol for 28 days resulted in diminished performance in sucrose preference test, splash test, forced swim test and marked elevation in plasma corticosterone levels. Chronic agmatine (5 and 10 mg/kg, ip, once daily) treatment started on day-15 and continued till the end of the CUMS protocol significantly increased sucrose preference, improved self-care and motivational behavior in the splash test and decreased duration of immobility in the forced swim test. Agmatine treatment also normalized the elevated corticosterone levels and prevented the body weight changes in chronically stressed animals. The pharmacological effect of agmatine was comparable to selective serotonin reuptake inhibitor, fluoxetine (10mg/kg, ip). Results of present study clearly demonstrated the anti-depressant like effect of agmatine in chronic unpredictable mild stress induced depression in mice. Thus the development of drugs based on brain agmatinergic modulation may represent a new potential approach for the treatment of stress related mood disorders like depression. © 2013 Published by Elsevier B.V.
Effect of Position- and Velocity-Dependent Forces on Reaching Movements at Different Speeds
Summa, Susanna; Casadio, Maura; Sanguineti, Vittorio
2016-01-01
The speed of voluntary movements is determined by the conflicting needs of maximizing accuracy and minimizing mechanical effort. Dynamic perturbations, e.g., force fields, may be used to manipulate movements in order to investigate these mechanisms. Here, we focus on how the presence of position- and velocity-dependent force fields affects the relation between speed and accuracy during hand reaching movements. Participants were instructed to perform reaching movements under visual control in two directions, corresponding to either low or high arm inertia. The subjects were required to maintain four different movement durations (very slow, slow, fast, very fast). The experimental protocol included three phases: (i) familiarization—the robot generated no force; (ii) force field—the robot generated a force; and (iii) after-effect—again, no force. Participants were randomly assigned to four groups, depending on the type of force that was applied during the “force field” phase. The robot was programmed to generate position-dependent forces—with positive (K+) or negative stiffness (K−)—or velocity-dependent forces, with either positive (B+) or negative viscosity (B−). We focused on path curvature, smoothness, and endpoint error; in the latter we distinguished between bias and variability components. Movements in the high-inertia direction are smoother and less curved; smoothness also increases with movement speed. Endpoint bias and variability are greater in, respectively, the high and low inertia directions. A robust dependence on movement speed was only observed in the longitudinal components of both bias and variability. The strongest and more consistent effects of perturbation were observed with negative viscosity (B−), which resulted in increased variability during force field adaptation and in a reduction of the endpoint bias, which was retained in the subsequent after-effect phase. These findings confirm that training with negative viscosity produces lasting effects in movement accuracy at all speeds. PMID:27965559
UPM: unified policy-based network management
NASA Astrophysics Data System (ADS)
Law, Eddie; Saxena, Achint
2001-07-01
Besides providing network management to the Internet, it has become essential to offer different Quality of Service (QoS) to users. Policy-based management provides control on network routers to achieve this goal. The Internet Engineering Task Force (IETF) has proposed a two-tier architecture whose implementation is based on the Common Open Policy Service (COPS) protocol and Lightweight Directory Access Protocol (LDAP). However, there are several limitations to this design such as scalability and cross-vendor hardware compatibility. To address these issues, we present a functionally enhanced multi-tier policy management architecture design in this paper. Several extensions are introduced thereby adding flexibility and scalability. In particular, an intermediate entity between the policy server and policy rule database called the Policy Enforcement Agent (PEA) is introduced. By keeping internal data in a common format, using a standard protocol, and by interpreting and translating request and decision messages from multi-vendor hardware, this agent allows a dynamic Unified Information Model throughout the architecture. We have tailor-made this unique information system to save policy rules in the directory server and allow executions of policy rules with dynamic addition of new equipment during run-time.
Abraham, Rohit; Vyas, Dinesh; Narayan, Mayur; Vyas, Arpita
2015-12-01
Trauma-related injury in fast developing countries are linked to 90% of international mortality rates, which can be greatly reduced by improvements in often non-existent or non-centralized emergency medical systems (EMS)-particularly in the pre-hospital care phase. Traditional trauma training protocols-such as Advanced Trauma Life Support (ATLS), International Trauma Life Support (ITLS), and Basic Life Support (BLS)-have failed to produce an effective pre-hospital ground force of medical first responders. To overcome these barriers, we propose a new four-tiered set of trauma training protocols: Massive Open Online Course (MOOC) Trauma Training, Acute Trauma Training (ATT), Broad Trauma Training (BTT), and Cardiac and Trauma Training (CTT). These standards are specifically differentiated to accommodate the educational and socioeconomic diversity found in fast developing settings, where each free course is taught in native, lay language while ensuring the education standards are maintained by fully incorporating high-fidelity simulation, video-recorded debriefing, and retraining. The innovative pedagogy of this trauma education program utilizes MOOC for global scalability and a "train-the-trainer" approach for exponential growth-both components help fast developing countries reach a critical mass of first responders needed for the base of an evolving EMS.
Duration Dependent Effect of Static Stretching on Quadriceps and Hamstring Muscle Force.
Alizadeh Ebadi, Leyla; Çetin, Ebru
2018-03-13
The aim of this study was to determine the acute effect of static stretching on hamstring and quadriceps muscles' isokinetic strength when applied for various durations to elite athletes, to investigate the effect of different static stretching durations on isokinetic strength, and finally to determine the optimal stretching duration. Fifteen elite male athletes from two different sport branches (10 football and five basketball) participated in this study. Experimental protocol was designed as 17 repetitive static stretching exercises for hamstring and quadriceps muscle groups according to the indicated experimental protocols; ((A) 5 min jogging; (B) 5 min jogging followed by 15 s static stretching; (C) 5 min jogging followed by 30 s static stretching; (D) 5 min jogging, followed by static stretching for 45 s). Immediately after each protocol, an isokinetic strength test consisting of five repetitions at 60°/s speed and 20 repetitions at 180°/s speed was recorded for the right leg by the Isomed 2000 device. Friedman variance analysis test was employed for data analysis. According to the analyzes, it was observed that 5 min jogging and 15 s stretching exercises increased the isokinetic strength, whereas 30 and 45 s stretching exercises caused a decrease.
Duration Dependent Effect of Static Stretching on Quadriceps and Hamstring Muscle Force
Çetin, Ebru
2018-01-01
The aim of this study was to determine the acute effect of static stretching on hamstring and quadriceps muscles’ isokinetic strength when applied for various durations to elite athletes, to investigate the effect of different static stretching durations on isokinetic strength, and finally to determine the optimal stretching duration. Fifteen elite male athletes from two different sport branches (10 football and five basketball) participated in this study. Experimental protocol was designed as 17 repetitive static stretching exercises for hamstring and quadriceps muscle groups according to the indicated experimental protocols; ((A) 5 min jogging; (B) 5 min jogging followed by 15 s static stretching; (C) 5 min jogging followed by 30 s static stretching; (D) 5 min jogging, followed by static stretching for 45 s). Immediately after each protocol, an isokinetic strength test consisting of five repetitions at 60°/s speed and 20 repetitions at 180°/s speed was recorded for the right leg by the Isomed 2000 device. Friedman variance analysis test was employed for data analysis. According to the analyzes, it was observed that 5 min jogging and 15 s stretching exercises increased the isokinetic strength, whereas 30 and 45 s stretching exercises caused a decrease.
Recent advances in magnetofection and its potential to deliver siRNAs in vitro.
Mykhaylyk, Olga; Zelphati, Olivier; Hammerschmid, Edelburga; Anton, Martina; Rosenecker, Joseph; Plank, Christian
2009-01-01
This chapter describes how to design and conduct experiments to deliver siRNA to adherent mammalian cells in vitro by magnetic force-assisted transfection using self-assembled complexes of small interfering RNA (siRNA) and cationic lipids or polymers that are associated with magnetic nanoparticles. These magnetic complexes are targeted to the cell surface by the application of a magnetic gradient field. In this chapter, first we describe the synthesis of magnetic nanoparticles for magnetofection and the association of siRNA with the magnetic components of the transfection complex. Second, a simple protocol is described in order to evaluate magnetic responsiveness of the magnetic siRNA transfection complexes and estimate the complex loading with magnetic nanoparticles. Third, protocols are provided for the preparation of magnetic lipoplexes and polyplexes of siRNA, magnetofection, downregulation of gene expression, and the determination of cell viability. The addition of INF-7 peptide, a fusogenic peptide, to the magnetic transfection triplexes improved gene silencing in HeLa cells. The described protocols are also valuable for screening vector compositions and novel magnetic nanoparticle preparations to optimize siRNA transfection by magnetofection in every cell type.
Calcium dependent current recordings in Xenopus laevis oocytes in microgravity
NASA Astrophysics Data System (ADS)
Wuest, Simon L.; Roesch, Christian; Ille, Fabian; Egli, Marcel
2017-12-01
Mechanical unloading by microgravity (or weightlessness) conditions triggers profound adaptation processes at the cellular and organ levels. Among other mechanisms, mechanosensitive ion channels are thought to play a key role in allowing cells to transduce mechanical forces. Previous experiments performed under microgravity have shown that gravity affects the gating properties of ion channels. Here, a method is described to record a calcium-dependent current in native Xenopus laevis oocytes under microgravity conditions during a parabolic flight. A 3-voltage-step protocol was applied to provoke a calcium-dependent current. This current increased with extracellular calcium concentration and could be reduced by applying extracellular gadolinium. The custom-made ;OoClamp; hardware was validated by comparing the results of the 3-voltage-step protocol to results obtained with a well-established two-electrode voltage clamp (TEVC). In the context of the 2nd Swiss Parabolic Flight Campaign, we tested the OoClamp and the method. The setup and experiment protocol worked well in parabolic flight. A tendency that the calcium-dependent current was smaller under microgravity than under 1 g condition could be observed. However, a conclusive statement was not possible due to the small size of the data base that could be gathered.
Head, Stewart I.; Greenaway, Bronwen; Chan, Stephen
2011-01-01
Background Creatine supplementation can improve performance during high intensity exercise in humans and improve muscle strength in certain myopathies. In this present study, we investigated the direct effects of acute creatine incubation on isolated mouse fast-twitch EDL muscles, and examined how these effects change with fatigue. Methods and Results The extensor digitorum longus muscle from mice aged 12–14 weeks was isolated and stimulated with field electrodes to measure force characteristics in 3 different states: (i) before fatigue; (ii) immediately after a fatigue protocol; and (iii) after recovery. These served as the control measurements for the muscle. The muscle was then incubated in a creatine solution and washed. The measurement of force characteristics in the 3 different states was then repeated. In un-fatigued muscle, creatine incubation increased the maximal tetanic force. In fatigued muscle, creatine treatment increased the force produced at all frequencies of stimulation. Incubation also increased the rate of twitch relaxation and twitch contraction in fatigued muscle. During repetitive fatiguing stimulation, creatine-treated muscles took 55.1±9.5% longer than control muscles to lose half of their original force. Measurement of weight changes showed that creatine incubation increased EDL muscle mass by 7%. Conclusion Acute creatine application improves force production in isolated fast-twitch EDL muscle, and these improvements are particularly apparent when the muscle is fatigued. One likely mechanism for this improvement is an increase in Ca2+ sensitivity of contractile proteins as a result of ionic strength decreases following creatine incubation. PMID:21850234
Force feedback effects on single molecule hopping and pulling experiments
NASA Astrophysics Data System (ADS)
Rico-Pasto, M.; Pastor, I.; Ritort, F.
2018-03-01
Single-molecule experiments with optical tweezers have become an important tool to study the properties and mechanisms of biological systems, such as cells and nucleic acids. In particular, force unzipping experiments have been used to extract the thermodynamics and kinetics of folding and unfolding reactions. In hopping experiments, a molecule executes transitions between the unfolded and folded states at a preset value of the force [constant force mode (CFM) under force feedback] or trap position [passive mode (PM) without feedback] and the force-dependent kinetic rates extracted from the lifetime of each state (CFM) and the rupture force distributions (PM) using the Bell-Evans model. However, hopping experiments in the CFM are known to overestimate molecular distances and folding free energies for fast transitions compared to the response time of the feedback. In contrast, kinetic rate measurements from pulling experiments have been mostly done in the PM while the CFM is seldom implemented in pulling protocols. Here, we carry out hopping and pulling experiments in a short DNA hairpin in the PM and CFM at three different temperatures (6 °C, 25 °C, and 45 °C) exhibiting largely varying kinetic rates. As expected, we find that equilibrium hopping experiments in the CFM and PM perform well at 6 °C (where kinetics are slow), whereas the CFM overestimates molecular parameters at 45 °C (where kinetics are fast). In contrast, nonequilibrium pulling experiments perform well in both modes at all temperatures. This demonstrates that the same kind of feedback algorithm in the CFM leads to more reliable determination of the folding reaction parameters in irreversible pulling experiments.
Force feedback effects on single molecule hopping and pulling experiments.
Rico-Pasto, M; Pastor, I; Ritort, F
2018-03-28
Single-molecule experiments with optical tweezers have become an important tool to study the properties and mechanisms of biological systems, such as cells and nucleic acids. In particular, force unzipping experiments have been used to extract the thermodynamics and kinetics of folding and unfolding reactions. In hopping experiments, a molecule executes transitions between the unfolded and folded states at a preset value of the force [constant force mode (CFM) under force feedback] or trap position [passive mode (PM) without feedback] and the force-dependent kinetic rates extracted from the lifetime of each state (CFM) and the rupture force distributions (PM) using the Bell-Evans model. However, hopping experiments in the CFM are known to overestimate molecular distances and folding free energies for fast transitions compared to the response time of the feedback. In contrast, kinetic rate measurements from pulling experiments have been mostly done in the PM while the CFM is seldom implemented in pulling protocols. Here, we carry out hopping and pulling experiments in a short DNA hairpin in the PM and CFM at three different temperatures (6 °C, 25 °C, and 45 °C) exhibiting largely varying kinetic rates. As expected, we find that equilibrium hopping experiments in the CFM and PM perform well at 6 °C (where kinetics are slow), whereas the CFM overestimates molecular parameters at 45 °C (where kinetics are fast). In contrast, nonequilibrium pulling experiments perform well in both modes at all temperatures. This demonstrates that the same kind of feedback algorithm in the CFM leads to more reliable determination of the folding reaction parameters in irreversible pulling experiments.
Enhancing a slow and weak optomechanical nonlinearity with delayed quantum feedback
Wang, Zhaoyou; Safavi-Naeini, Amir H.
2017-01-01
A central goal of quantum optics is to generate large interactions between single photons so that one photon can strongly modify the state of another one. In cavity optomechanics, photons interact with the motional degrees of freedom of an optical resonator, for example, by imparting radiation pressure forces on a movable mirror or sensing minute fluctuations in the position of the mirror. Here, we show that the optical nonlinearity arising from these effects, typically too small to operate on single photons, can be sufficiently enhanced with feedback to generate large interactions between single photons. We propose a protocol that allows photons propagating in a waveguide to interact with each other through multiple bounces off an optomechanical system. The protocol is analysed by evolving the full many-body quantum state of the waveguide-coupled system, illustrating that large photon–photon interactions mediated by mechanical motion may be within experimental reach. PMID:28677674
Graphene Nanobubbles Produced by Water Splitting.
An, Hongjie; Tan, Beng Hau; Moo, James Guo Sheng; Liu, Sheng; Pumera, Martin; Ohl, Claus-Dieter
2017-05-10
Graphene nanobubbles are of significant interest due to their ability to trap mesoscopic volumes of gas for various applications in nanoscale engineering. However, conventional protocols to produce such bubbles are relatively elaborate and require specialized equipment to subject graphite samples to high temperatures or pressures. Here, we demonstrate the formation of graphene nanobubbles between layers of highly oriented pyrolytic graphite (HOPG) with electrolysis. Although this process can also lead to the formation of gaseous surface nanobubbles on top of the substrate, the two types of bubbles can easily be distinguished using atomic force microscopy. We estimated the Young's modulus, internal pressure, and the thickness of the top membrane of the graphene nanobubbles. The hydrogen storage capacity can reach ∼5 wt % for a graphene nanobubble with a membrane that is four layers thick. The simplicity of our protocol paves the way for such graphitic nanobubbles to be utilized for energy storage and industrial applications on a wide scale.
Adaptive change in electrically stimulated muscle: a framework for the design of clinical protocols.
Salmons, Stanley
2009-12-01
Adult mammalian skeletal muscles have a remarkable capacity for adapting to increased use. Although this behavior is familiar from the changes brought about by endurance exercise, it is seen to a much greater extent in the response to long-term neuromuscular stimulation. The associated phenomena include a markedly increased resistance to fatigue, and this is the key to several clinical applications. However, a more rational basis is needed for designing regimes of stimulation that are conducive to an optimal outcome. In this review I examine relevant factors, such as the amount, frequency, and duty cycle of stimulation, the influence of force generation, and the animal model. From these considerations a framework emerges for the design of protocols that yield an overall functional profile appropriate to the application. Three contrasting examples illustrate the issues that need to be addressed clinically.
Quantum-noise randomized data encryption for wavelength-division-multiplexed fiber-optic networks
DOE Office of Scientific and Technical Information (OSTI.GOV)
Corndorf, Eric; Liang Chuang; Kanter, Gregory S.
2005-06-15
We demonstrate high-rate randomized data-encryption through optical fibers using the inherent quantum-measurement noise of coherent states of light. Specifically, we demonstrate 650 Mbit/s data encryption through a 10 Gbit/s data-bearing, in-line amplified 200-km-long line. In our protocol, legitimate users (who share a short secret key) communicate using an M-ry signal set while an attacker (who does not share the secret key) is forced to contend with the fundamental and irreducible quantum-measurement noise of coherent states. Implementations of our protocol using both polarization-encoded signal sets as well as polarization-insensitive phase-keyed signal sets are experimentally and theoretically evaluated. Different from the performancemore » criteria for the cryptographic objective of key generation (quantum key-generation), one possible set of performance criteria for the cryptographic objective of data encryption is established and carefully considered.« less
Determining the optimal load for jump squats: a review of methods and calculations.
Dugan, Eric L; Doyle, Tim L A; Humphries, Brendan; Hasson, Christopher J; Newton, Robert U
2004-08-01
There has been an increasing volume of research focused on the load that elicits maximum power output during jump squats. Because of a lack of standardization for data collection and analysis protocols, results of much of this research are contradictory. The purpose of this paper is to examine why differing methods of data collection and analysis can lead to conflicting results for maximum power and associated optimal load. Six topics relevant to measurement and reporting of maximum power and optimal load are addressed: (a) data collection equipment, (b) inclusion or exclusion of body weight force in calculations of power, (c) free weight versus Smith machine jump squats, (d) reporting of average versus peak power, (e) reporting of load intensity, and (f) instructions given to athletes/ participants. Based on this information, a standardized protocol for data collection and reporting of jump squat power and optimal load is presented.
The global gridded crop model intercomparison: Data and modeling protocols for Phase 1 (v1.0)
Elliott, J.; Müller, C.; Deryng, D.; ...
2015-02-11
We present protocols and input data for Phase 1 of the Global Gridded Crop Model Intercomparison, a project of the Agricultural Model Intercomparison and Improvement Project (AgMIP). The project consist of global simulations of yields, phenologies, and many land-surface fluxes using 12–15 modeling groups for many crops, climate forcing data sets, and scenarios over the historical period from 1948 to 2012. The primary outcomes of the project include (1) a detailed comparison of the major differences and similarities among global models commonly used for large-scale climate impact assessment, (2) an evaluation of model and ensemble hindcasting skill, (3) quantification ofmore » key uncertainties from climate input data, model choice, and other sources, and (4) a multi-model analysis of the agricultural impacts of large-scale climate extremes from the historical record.« less
1995-03-01
The American Association of Critical-Care Nurse's (AACN) Thunder Project was conceptualized and developed to provide critical-care nurses with a research protocol ready for institutional review and implementation. Project goals included providing a research package (protocol, educational, and data collection materials) and a topic of clinical significance to critical-care nurses. Site coordinators and research associates were identified at participating institutions to coordinate and implement all study activities. In this article, an evaluation study undertaken to recount perceptions of site coordinators and research associates in relation to project goals and research experience is described. Data demonstrated that study goals were achieved, and research experience was considered professionally enhancing. Written comments described barriers to project implementation at participating sites. Obtaining informed consent and physician approval and/or cooperation were identified as significant barriers to implementation at some sites.
Enhancing a slow and weak optomechanical nonlinearity with delayed quantum feedback
NASA Astrophysics Data System (ADS)
Wang, Zhaoyou; Safavi-Naeini, Amir H.
2017-07-01
A central goal of quantum optics is to generate large interactions between single photons so that one photon can strongly modify the state of another one. In cavity optomechanics, photons interact with the motional degrees of freedom of an optical resonator, for example, by imparting radiation pressure forces on a movable mirror or sensing minute fluctuations in the position of the mirror. Here, we show that the optical nonlinearity arising from these effects, typically too small to operate on single photons, can be sufficiently enhanced with feedback to generate large interactions between single photons. We propose a protocol that allows photons propagating in a waveguide to interact with each other through multiple bounces off an optomechanical system. The protocol is analysed by evolving the full many-body quantum state of the waveguide-coupled system, illustrating that large photon-photon interactions mediated by mechanical motion may be within experimental reach.
Experimental loss-tolerant quantum coin flipping
Berlín, Guido; Brassard, Gilles; Bussières, Félix; Godbout, Nicolas; Slater, Joshua A.; Tittel, Wolfgang
2011-01-01
Coin flipping is a cryptographic primitive in which two distrustful parties wish to generate a random bit to choose between two alternatives. This task is impossible to realize when it relies solely on the asynchronous exchange of classical bits: one dishonest player has complete control over the final outcome. It is only when coin flipping is supplemented with quantum communication that this problem can be alleviated, although partial bias remains. Unfortunately, practical systems are subject to loss of quantum data, which allows a cheater to force a bias that is complete or arbitrarily close to complete in all previous protocols and implementations. Here we report on the first experimental demonstration of a quantum coin-flipping protocol for which loss cannot be exploited to cheat better. By eliminating the problem of loss, which is unavoidable in any realistic setting, quantum coin flipping takes a significant step towards real-world applications of quantum communication. PMID:22127057
Behavioral Effects of Acclimatization To Restraint Protocol Used for Awake Animal Imaging
Reed, Michael D.; Pira, Ashley S.; Febo, Marcelo
2013-01-01
Functional MRI of awake rats involves acclimatization to restraint to minimize motion. We designed a study to examine the effects of an acclimatization protocol (5 days of restraint, 60 minutes per day) on the emission of 22-kHz ultrasonic vocalizations and performance on a forced swim test (FST). Our results show that USV calls are reduced significantly by day 3, 4 and 5 of acclimatization. Although rats show less climbing activity (and more immobility) in FST on day 5 compared to the 1st day of restraint acclimatization, the difference is gone once animals are given a 2 week hiatus. Overall, we show that animals adapt to the restraint over the five day period, however, restraint may introduce confounding behavioral outcomes that may hinder the interpretation of results derived from awake rat imaging. The present data warrant further testing of the effects of MRI restraint on behavior. PMID:23562621
Olszewski, Waldemar L; Zaleska, Marzanna; Michelin, Sandro
2016-12-01
Edema fluid in lymphedematous limbs should be evacuated to sites where it can be absorbed. It should be moved either to the hypogastrium or arm/scapular regions along tissue channels or implanted silicon channels or through lymphovenous anastomoses. For that purpose, the manual lymphatic drainage of limb is an effective method. Standardization of manual massage applied force and timing becomes necessary. A device with known pressing area and continuously showing the applied force while moving it toward the root of the limb is needed. Moreover, force could be adjusted to the stiffness of the massaged tissues that varies at different levels of the limb. Results from such a device would be repeatable and reproducible by others. In this study we present data on tissue fluid hydromechanics obtained from 20 patients with obstructive limb lymphedema during massage with a massaging roller called Linforoll. Linforoll is composed of a hand piece with roller and pressure sensor connected wireless to the computer displaying the pressure curve of the applied force. Electron microscopy studies for checking eventual tissue changes were done. Linforoll provides the possibilities of: 1) regulating the applied force according to the hydromechanic conditions of the massaged tissues; 2) standardization of massage repeatable in the same patient; 3) decrease of limb volume; 4) evident increase in tissue elasticity; 5) application as a driving force for fluid flow along the surgically implanted tubing and vessels running to the lymphovenous shunts.
Efficacy of denture adhesives in maxillary dentures using gnathodynamometry: a comparative study.
Polyzois, Gregory; Lagouvardos, Panagiotis; Frangou, Maria; Stefaniotis, Theodoros
2011-07-01
The purpose of this study was to investigate the effect of four commercially available denture adhesives on the incisal and premolar dislodgement forces of maxillary complete dentures by using an electronic and disposable gnathodynamometer and compare the measured incisal forces for differences. This study was conducted with 12 complete maxillary denture wearers. Four commercially available denture adhesives Super Corega(®), Corega Ultra(®), Super Corega Powder(®) and Fittydent Cationic(®) were investigated. Testing protocol and sequence included baseline measurements without adhesives (control) for previous and new dentures and then replications of measurements with the four adhesives. Maximum dislodgement forces were recorded in two sites between central incisors and the left 2nd premolars by using an electronic and disposable gnathodynamometer. To estimate the effect of the different adhesives on the dislodgement forces, data were analyzed by a 2- and 3-way ANOVA, while for estimating the agreement of the two devices a Bland-Altman and Mountain plots were used. ANOVAs indicated significant differences between adhesives (p < 0.05), denture types (p < 0.05) and biting sites (p < 0.05) with both devices. Bland-Altman plot and Mountain plots indicated a poor agreement of the two devices. It was concluded that denture adhesives increase the denture dislodgement forces, but with differences among them. The two devices do not highly agree with each other, but each one alone is useful in estimating dislodgement forces in clinical practice and research.
SpaceWire Protocol ID: What Does It Mean To You?
NASA Technical Reports Server (NTRS)
Rakow, Glenn; Schnurr, Richard; Gilley, Daniel; Parks, Steve
2006-01-01
Spacewire is becoming a popular solution for satellite high-speed data buses because it is a simple standard that provides great flexibility for a wide range of system requirements. It is simple in packet format and protocol, allowing users to easily tailor their implementation for their specific application. Some of the attractive aspects of Spacewire that make it easy to implement also make it hard for future reuse. Protocol reuse is difficult because Spacewire does not have a defined mechanism to communicate with the higher layers of the protocol stack. This has forced users of Spacewire to define unique packet formats and define how these packets are to be processed. Each mission writes their own Interface Control Document (ICD) and tailors Spacewire for their specific requirements making reuse difficult. Part of the reason for this habit may be because engineers typically optimize designs for their own requirements in the absence of a standard. This is an inefficient use of project resources and costs more to develop missions. A new packet format for Spacewire has been defined as a solution for this problem. This new packet format is a compliment to the Spacewire standard that will support protocol development upon Spacewire. The new packet definition does not replace the current packet structure, i.e., does not make the standard obsolete, but merely extends the standard for those who want to develop protocols over Spacewire. The Spacewire packet is defined with the first part being the Destination Address, which may be one or more bytes. This is followed by the packet cargo, which is user defined. The cargo is truncated with an End-Of-Packet (EOP) marker. This packet structure offers low packet overhead and allows the user to define how the contents are to be formatted. It also provides for many different addressing schemes, which provide flexibility in the system. This packet flexibility is typically an attractive part of the Spacewire. The new extended packet format adds one new field to the packet that greatly enhances the capability of Spacewire. This new field called the Protocol Identifier (ID) is used to identify the packet contents and the associated processing for the packet. This feature along with the restriction in the packet format that uses the Protocol ID, allows a deterministic method of decoding packets that was not before possible. The first part of the packet is still the Destination Address, which still conforms to the original standard but with one restriction. The restriction is that the first byte seen at the destination by the user needs to be a logical address, independent of the addressing scheme used. The second field is defined as the Protocol ID, which is usually one byte in length. The packet cargo (user defined) follows the Protocol ID. After the packet cargo is the EOP, which defines the end of packet. The value of the Protocol ID is assigned by the Spacewire working group and the protocol description published for others to use. The development of Protocols for Spacewire is currently the area of greatest activity by the Spacewire working group. The first protocol definition by the working group has been completed and is now in the process of formal standardization. There are many other protocols in development for missions that have not yet received formal Protocol ID assignment, but even if the protocols are not formally assigned a value, this effort will provide synergism for future developments.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Posas, Paula J., E-mail: pjposas@gmail.co
2011-04-15
The Protocol on Strategic Environmental Assessment (SEA) to the United Nations Economic Commission for Europe (UNECE) Espoo Convention came into force on 11 July 2010. This Protocol, to which the European Union is party, gives a legal basis for enhanced attention to human health in the SEA process. In this context, the United Kingdom's (UK's) 2007 Draft Guidance on Health in Strategic Environmental Assessment represents an important early government-led effort to bring health issues and public health considerations more significantly into the SEA process. Since the UK is a worldwide leader in environmental and various other types of impact assessment,more » and since other countries may eventually consider its example in efforts to meet UNECE SEA Protocol requirements, scrutiny of its outputs is warranted. This paper thus examines the UK's Draft Guidance from both HIA academic and practitioner perspectives. First it assesses the extent to which the Draft Guidance reflects recent issues and lessons learned in the academic literature. In order to make the assessment, a meta-analysis of 70 HIA-related peer-reviewed articles was undertaken to extract authors' priority recommendations. These recommendations were subsequently compared with the contents of the Draft Guidance. Secondly, the Draft Guidance was assessed for its accordance with recommendations of the UNECE SEA Protocol background paper written by two HIA practitioners. Overall, the Draft Guidance's accordance with both sets of recommendations was found to be high, with only a few easily-remedied gaps. This evaluation suggests that the UK's Draft Guidance can be a useful starting point in the creation of future guidance on health in SEA in both the UK and other countries.« less
Khozoee, Baktash; Mafi, Pouya; Mafi, Reza; Khan, Wasim S
2017-01-01
Mechanical stimulation is a key factor in articular cartilage generation and maintenance. Bioreactor systems have been designed and built in order to deliver specific types of mechanical stimulation. The focus has been twofold, applying a type of preconditioning in order to stimulate cell differentiation, and to simulate in vivo conditions in order to gain further insight into how cells respond to different stimulatory patterns. Due to the complex forces at work within joints, it is difficult to simulate mechanical conditions using a bioreactor. The aim of this review is to gain a deeper understanding of the complexities of mechanical stimulation protocols by comparing those employed in bioreactors in the context of tissue engineering for articular cartilage, and to consider their effects on cultured cells. Allied and Complementary Medicine 1985 to 2016, Ovid MEDLINE[R] 1946 to 2016, and Embase 1974 to 2016 were searched using key terms. Results were subject to inclusion and exclusion criteria, key findings summarised into a table and subsequently discussed. Based on this review it is overwhelmingly clear that mechanical stimulation leads to increased chondrogenic properties in the context of bioreactor articular cartilage tissue engineering using human cells. However, given the variability and lack of controlled factors between research articles, results are difficult to compare, and a standardised method of evaluating stimulation protocols proved challenging. With improved standardisation in mechanical stimulation protocol reporting, bioreactor design and building processes, along with a better understanding of joint behaviours, we hope to perform a meta-analysis on stimulation protocols and methods. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.
PANATIKI: A Network Access Control Implementation Based on PANA for IoT Devices
Sanchez, Pedro Moreno; Lopez, Rafa Marin; Gomez Skarmeta, Antonio F.
2013-01-01
Internet of Things (IoT) networks are the pillar of recent novel scenarios, such as smart cities or e-healthcare applications. Among other challenges, these networks cover the deployment and interaction of small devices with constrained capabilities and Internet protocol (IP)-based networking connectivity. These constrained devices usually require connection to the Internet to exchange information (e.g., management or sensing data) or access network services. However, only authenticated and authorized devices can, in general, establish this connection. The so-called authentication, authorization and accounting (AAA) services are in charge of performing these tasks on the Internet. Thus, it is necessary to deploy protocols that allow constrained devices to verify their credentials against AAA infrastructures. The Protocol for Carrying Authentication for Network Access (PANA) has been standardized by the Internet engineering task force (IETF) to carry the Extensible Authentication Protocol (EAP), which provides flexible authentication upon the presence of AAA. To the best of our knowledge, this paper is the first deep study of the feasibility of EAP/PANA for network access control in constrained devices. We provide light-weight versions and implementations of these protocols to fit them into constrained devices. These versions have been designed to reduce the impact in standard specifications. The goal of this work is two-fold: (1) to demonstrate the feasibility of EAP/PANA in IoT devices; (2) to provide the scientific community with the first light-weight interoperable implementation of EAP/PANA for constrained devices in the Contiki operating system (Contiki OS), called PANATIKI. The paper also shows a testbed, simulations and experimental results obtained from real and simulated constrained devices. PMID:24189332
PANATIKI: a network access control implementation based on PANA for IoT devices.
Moreno Sanchez, Pedro; Marin Lopez, Rafa; Gomez Skarmeta, Antonio F
2013-11-01
Internet of Things (IoT) networks are the pillar of recent novel scenarios, such as smart cities or e-healthcare applications. Among other challenges, these networks cover the deployment and interaction of small devices with constrained capabilities and Internet protocol (IP)-based networking connectivity. These constrained devices usually require connection to the Internet to exchange information (e.g., management or sensing data) or access network services. However, only authenticated and authorized devices can, in general, establish this connection. The so-called authentication, authorization and accounting (AAA) services are in charge of performing these tasks on the Internet. Thus, it is necessary to deploy protocols that allow constrained devices to verify their credentials against AAA infrastructures. The Protocol for Carrying Authentication for Network Access (PANA) has been standardized by the Internet engineering task force (IETF) to carry the Extensible Authentication Protocol (EAP), which provides flexible authentication upon the presence of AAA. To the best of our knowledge, this paper is the first deep study of the feasibility of EAP/PANA for network access control in constrained devices. We provide light-weight versions and implementations of these protocols to fit them into constrained devices. These versions have been designed to reduce the impact in standard specifications. The goal of this work is two-fold: (1) to demonstrate the feasibility of EAP/PANA in IoT devices; (2) to provide the scientific community with the first light-weight interoperable implementation of EAP/PANA for constrained devices in the Contiki operating system (Contiki OS), called PANATIKI. The paper also shows a testbed, simulations and experimental results obtained from real and simulated constrained devices.
Internetting tactical security sensor systems
NASA Astrophysics Data System (ADS)
Gage, Douglas W.; Bryan, W. D.; Nguyen, Hoa G.
1998-08-01
The Multipurpose Surveillance and Security Mission Platform (MSSMP) is a distributed network of remote sensing packages and control stations, designed to provide a rapidly deployable, extended-range surveillance capability for a wide variety of military security operations and other tactical missions. The baseline MSSMP sensor suite consists of a pan/tilt unit with video and FLIR cameras and laser rangefinder. With an additional radio transceiver, MSSMP can also function as a gateway between existing security/surveillance sensor systems such as TASS, TRSS, and IREMBASS, and IP-based networks, to support the timely distribution of both threat detection and threat assessment information. The MSSMP system makes maximum use of Commercial Off The Shelf (COTS) components for sensing, processing, and communications, and of both established and emerging standard communications networking protocols and system integration techniques. Its use of IP-based protocols allows it to freely interoperate with the Internet -- providing geographic transparency, facilitating development, and allowing fully distributed demonstration capability -- and prepares it for integration with the IP-based tactical radio networks that will evolve in the next decade. Unfortunately, the Internet's standard Transport layer protocol, TCP, is poorly matched to the requirements of security sensors and other quasi- autonomous systems in being oriented to conveying a continuous data stream, rather than discrete messages. Also, its canonical 'socket' interface both conceals short losses of communications connectivity and simply gives up and forces the Application layer software to deal with longer losses. For MSSMP, a software applique is being developed that will run on top of User Datagram Protocol (UDP) to provide a reliable message-based Transport service. In addition, a Session layer protocol is being developed to support the effective transfer of control of multiple platforms among multiple control stations.
NASA Technical Reports Server (NTRS)
Flynn-Evans, Erin; Gregory, Kevin; Arsintescu, Lucia; Whitmire, Alexandra
2016-01-01
Sleep loss, circadian desynchronization, and work overload occur to some extent for ground and flight crews, prior to and during spaceflight missions. Ground evidence indicates that such risk factors may lead to performance decrements and adverse health outcomes, which could potentially compromise mission objectives. Efforts are needed to identify the environmental and mission conditions that interfere with sleep and circadian alignment, as well as individual differences in vulnerability and resiliency to sleep loss and circadian desynchronization. Specifically, this report highlights a collection of new evidence to better characterize the risk and reveals new gaps in this risk as follows: Sleep loss is apparent during spaceflight. Astronauts consistently average less sleep during spaceflight relative to on the ground. The causes of this sleep loss remain unknown, however ground-based evidence suggests that the sleep duration of astronauts is likely to lead to performance impairment and short and long-term health consequences. Further research is needed in this area in order to develop screening tools to assess individual astronaut sleep need in order to quantify the magnitude of sleep loss during spaceflight; current and planned efforts in BHP's research portfolio address this need. In addition, it is still unclear whether the conditions of spaceflight environment lead to sleep loss or whether other factors, such as work overload lead to the reduced sleep duration. Future data mining efforts and continued data collection on the ISS will help to further characterize factors contributing to sleep loss. Sleep inertia has not been evaluated during spaceflight. Ground-based studies confirm that it takes two to four hours to achieve optimal performance after waking from a sleep episode. Sleep inertia has been associated with increased accidents and reduced performance in operational environments. Sleep inertia poses considerable risk during spaceflight when emergency situations necessitate that crewmembers wake from sleep and make quick decisions. A recently completed BHP investigation assesses the effects of sleep inertia upon abrupt awakening, with and without hypnotics currently used in spaceflight; results from this investigation will help to inform strategies relative to sleep inertia effects on performance. Circadian desynchrony has been observed during spaceflight. Circadian desynchrony during spaceflight develops due to schedule constraints requiring non-24 operations or 'slam-shifts' and due to insufficient or mis-timed light exposure. In addition, circadian misalignment has been associated with reduced sleep duration and increased medication use. In ground-based studies, circadian desynchrony has been associated with significant performance impairment and increased risk of accidents when operations coincide with the circadian nadir. There is a great deal of information available on how to manage circadian misalignment, however, there are currently no easily collected biomarkers that can be used during spaceflight to determine circadian phase. Current research efforts are addressing this gap. Work overload has been documented during current spaceflight operations. NASA has established work hour guidelines that limit shift duration, however, schedule creep, where duty requirements necessitate working beyond scheduled work hours, has been reported. This observation warrants the documentation of actual work hours in order to improve planning and in order to ensure that astronauts receive adequate down time. In addition to concerns about work overload, ground based evidence suggests that work underload may be a concern during deep space missions, where torpor may develop and physically demanding workload will be exchanged for monitoring of autonomous systems. Given that increased automation is anticipated for exploration vehicles, fatigue effects in the context of such systems needs to be further understood. Performance metrics are needed to evaluate fitness-for-duty during spaceflight. Although ground-based evidence supports the notion that sleep loss, circadian desynchronization and work overload lead to performance impairment, inconsistency in the measures used to evaluate performance during spaceflight make it difficult to evaluate the magnitude of performance impairment during spaceflight. Work is underway to standardize measures of performance evaluation during spaceflight. Once established, such performance indicators need to be correlated with operational performance. Individual differences in sleep need and circadian preference, phase shifting ability and period have been documented in ground-based studies. Individual differences in response to sleep loss and circadian misalignment have also been documented and are presumed to be associated with genetic polymorphisms. No studies have systematically reported individual differences in sleep or circadian-related outcomes during spaceflight. More work is needed in this area in order to identify genetic or phenotypic biomarkers that predict resilience or vulnerability to sleep loss in order to personalize countermeasure strategies and mitigate performance impairment during spaceflight. Two laboratory and field investigations specific to this topic are currently ongoing; additional efforts, including an effort to mine existing biological data from spaceflight relative to sleep and circadian outcomes, are planned. Sex differences in sleep need and circadian period and phase have been reported in ground-based studies. The impact of these sex differences on performance is unclear. Sex differences in sleep need and circadian rhythms have not been systematically studied during spaceflight, presumably due to the small number of women that have flown in space. More research is needed in this area to evaluate whether any of the observed sex differences in physiology lead to altered performance in spaceflight and on the ground.
Frequency and severity of reactions to a 325-mg aspirin dose during desensitization.
Schuler, Charles F; Baldwin, James L; Baptist, Alan P
2017-03-01
The frequency with which patients with aspirin-exacerbated respiratory disease (AERD) react to 325 mg of aspirin during aspirin desensitization, or fail to react at all, is not fully known. To determine the rate and type of reaction at 325 mg of aspirin during desensitization. A retrospective study of 104 patients who underwent aspirin desensitization from 2010 to 2016 was performed. A standard desensitization protocol (starting at 20-40 mg, progressing through 325 mg, and extinguishing reactions by dose repetition) was used. Reactions were defined by upper respiratory tract symptoms, lower respiratory tract symptoms, and/or forced expiratory volume in 1 second decrease of 15% or greater. Patients who did and did not react were compared by logistic regression. Eighty-four patients reacted (81%) and 20 did not (19%). Seventy-seven patients who had a provoking reaction at 162 mg of aspirin or less subsequently extinguished their reactions before they reached a dose of 325 mg and had no problems at that dose; one subsequent 325-mg reaction occurred during a protocol violation. One initial provoking reaction to 325 mg occurred. Both 325-mg reactions were mild, and neither met the forced expiratory volume in 1 second criterion for a clinically meaningful change. The remaining 5 patients could not complete the protocol because of persistent reactions or social reasons. Reactors were more likely to have had asthma for more than 10 years than nonreactors (odds ratio, 3.2; 95% confidence interval, 1.0-10.3; P = .05). During aspirin desensitization for AERD, provoking reactions at the 325-mg dose are rare (1%) and mild. Patients who react at 162 mg or less and extinguish their reactions may be able to administer the 325-mg dose at home. Copyright © 2016 American College of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.
Ng, Choon Ta; Chee, Tek Siong; Ling, Lee Fong; Lee, Yian Ping; Ching, Chi Keong; Chua, Terrance S J; Cheok, Christopher; Ong, Hean Yee
2011-06-01
Hypertrophic cardiomyopathy is a leading cause of sudden cardiac death (SCD) in young people in the USA. Pre-participation screening for athletes might reduce the incidence of SCD. In Singapore, military service is compulsory for all young able-bodied male citizens. The Singapore Armed Forces Electrocardiogram and Echocardiogram (SAFE) pre-participation screening protocol based on the Italian programme was introduced. This study evaluates the prevalence of hypertrophic cardiomyopathy (HCM) in a young male South-East Asian population. From October 2008 to May 2009, all male military conscripts underwent pre-participation screening. For all conscripts whose electrocardiogram (ECG) findings fulfilled any of these pre-specified criteria (Group A), direct referral for a transthoracic echocardiogram was mandatory. Conscripts with ECG findings other than pre-specified criteria (e.g. T-wave inversions, repolarization abnormalities) were referred for secondary screening by cardiologists (Group B), which could include echocardiography. Out of 18 476 subjects screened during the study period, 988 (5.3%) subjects were fast tracked for echocardiogram (Group A). Of them, there were three (0.3%) cases with severe abnormalities; there was one case each of HCM, bicuspid aortic valve with significant aortic valve regurgitation, and atrial septal defect with right ventricular systolic dysfunction. The patient with HCM had left axis deviation on ECG. None of the 215 patients who underwent echocardiography following cardiology consult (Group B) had HCM. The prevalence of HCM in our young male population (mean age 19.5, range 16-27) using an ECG-based screening protocol was 0.005%; this appeared lower than published data from other geographical cohorts. Possible explanations include a later age of phenotypic manifestation in our population, limitations of the ECG criteria for screening, or a truly lower prevalence of HCM. More population-based longitudinal studies would be needed to ascertain the true prevalence of HCM in our South-East Asian population.
Asymmetry after hamstring injury in English Premier League: issue resolved, or perhaps not?
Barreira, P; Drust, B; Robinson, M A; Vanrenterghem, J
2015-06-01
Hamstring injuries constitute one of the most concerning injuries in English Premier League football, due to its high primary incidence but also its recurrence. Functional methods assessing hamstring function during high-risk performance tasks such as sprinting are vital to identify potential risk factors. The purpose of this study was to assess horizontal force deficits during maximum sprint running on a non-motorized treadmill in football players with previous history of hamstring strains as a pre-season risk-assessment in a club setting. 17 male football players from one Premier League Club were divided into 2 groups, experimental (n=6, age=24.5±2.3 years) and control (n=11, age=21.3±1.2 years), according to history of previous hamstring injury. Participants performed a protocol including a 10-s maximum sprint on a non-motorized treadmill. Force deficits during acceleration phase and steady state phases of the sprint were assessed between limbs and between groups. The main outcome measures were horizontal and vertical peak forces during the acceleration phase or steady state. There were no significant differences in peak forces between previously injured and non-injured limbs, or between groups, challenging the ideas around functional force deficits in sprint running as a diagnostic measure of hamstring re-injury risk. © Georg Thieme Verlag KG Stuttgart · New York.
Neuromuscular adaptations associated with knee joint angle-specific force change.
Noorkõiv, Marika; Nosaka, Kazunori; Blazevich, Anthony J
2014-08-01
Neuromuscular adaptations to joint angle-specific force increases after isometric training have not yet been fully elucidated. This study examined angle-specific neuromuscular adaptations in response to isometric knee extension training at short (SL, joint angle 38.1° ± 3.7°) versus long (LL, 87.5° ± 6.0°) muscle lengths. Sixteen men trained three times a week for 6 wk either at SL (n = 8) or LL (n = 8). Voluntary maximal isometric knee extensor (MVC) force, doublet twitch force, EMG amplitudes (EMG/Mmax), and voluntary activation during MVC force (VA%) were measured at eight knee joint angles (30°-100°) at weeks 0, 3, and 6. Muscle volume and cross-sectional area (CSA) were measured from magnetic resonance imaging scans, and fascicle length (Lf) was assessed using ultrasonography before and after training. Clear joint angle specificity of force increase was seen in SL but not in LL. The 13.4% ± 9.7% (P = 0.01) force increase around the training angle in SL was related to changes in vastus lateralis and vastus medialis EMG/Mmax around the training angle (r = 0.84-0.88, P < 0.05), without changes in the doublet twitch force-angle relation or muscle size. In LL, muscle volume and CSA increased and the changes in CSA at specific muscle regions were correlated with changes in MVC force. A 5.4% ± 4.9% (P = 0.001) increase in Lf found in both groups was not associated with angle-specific force changes. There were no angle-specific changes in VA%. The EMG/Mmax, although not VA%, results suggest that neural adaptations underpinned training-related changes at short quadriceps lengths, but hypertrophic changes predominated after training at long lengths. The findings of this study should contribute to the development of more effective and evidence-based rehabilitation and strength training protocols.
Venous Gas Emboli and Ambulation at 4.3 PSIA (Preliminary)
NASA Technical Reports Server (NTRS)
Conkin, J.; Pollock, N. W.; Natoli, M. J.; Martina, S. D.; Wessel, J. H., III; Gernhardt, M. L.
2016-01-01
Ambulation imparts compressive and decompressive forces into the lower body, potentially creating quasi-stable micronuclei that influence the outcome of hypobaric depressurizations. Hypotheses: ambulation before the conclusion of a denitrogenation (prebreathe) protocol at 14.7 pounds per square inch absolute is not sufficient to increase the incidence of venous gas emboli (VGE) at 4.3 pounds per square inch absolute but is sufficient if performed after tissues become supersaturated with nitrogen at 4.3 pounds per square inch absolute.
Shake and stew: a non-destructive PCR-ready DNA isolation method from a single preserved fish larva.
Alvarado Bremer, J R; Smith, B L; Moulton, D L; Lu, C-P; Cornic, M
2014-01-01
A rapid non-destructive alternative to isolate DNA from an individual fish larva is presented, based on the suspension of epithelial cells through vortex forces, and the release of DNA in a heated alkaline solution. DNA from >6056 fish larvae isolated using this protocol has yielded a high PCR amplification success rate (>93%), suggesting its applicability to other taxonomic groups or sources when tissue amount is the limiting factor. © 2014 The Fisheries Society of the British Isles.
Specialized physiological studies in support of manned space flight
NASA Technical Reports Server (NTRS)
Luft, U. C.
1973-01-01
The areas of physiological research reported include: (1) evaluation of the single-breath method for determining cardiac output, (2) optimum protocol for the assessment of cardio-pulmonary competence, (3) body fluids and electrolytes under conditions of single and combined stress, (4) re-evaluation of the open-circuit method for measuring metabolic rate with regard to the alleged metabolic production of gaseous nitrogen, and (5) the use of the forced-oscillation method to determine total respiratory conductance in healthy subjects and pulmonary patients.
2008-09-01
related scenarios related to US armed forces around the world . In the civilian setting, complete decontamination is the only accepted criteria before a...observation, a door for sample introduction, and four ports on the front panel for sensor placement. All glass surfaces were covered when used with CD gas...1999, 281, 1735-1745. 9. AOAC International Method 966.04; Official Methods of Analisis , 21’t ed.; Chapter 6: AOAC International: Gaithersburg, MD
1985-06-01
via the LSA process, to determine the best mix of support resource requirements. The data elements required for the LSA process would reside in an...homework. (ii) Policy to deal matrix digital data format/delivery defintion to replace paper world definitions in our current contractive procedures...2.2.2.1 NAPLPS. (North American Presentation Level Protocol Syntax) was developed for the videotex market during 1981-82, based on a series of